View Bid Results For Arcing Chamber Tenders

We found 57 Bid Results related to arcing chamber tenders. You can find Contractor details who won arcing chamber tenders along with contract details in Bid awards announcements section.

Filters
Stage
45
7
5
Tender Publishing Platform
1
56
State / UT
17
14
8
7
6
4
3
2
2
2
2
1
1
1
1
1
1
1
Contract Value
12
12
26
7
Publish Date
0
0
0
0
0
Sector
8
22
20
7
3
2
1
1
1
Ownership
4
35
20
1
1
Within keyword
Active filters:
Showing 1–2 of 57 tenders matching your filters
1.
Defence #11281747 Technical Bid
Tender For Provision Of Defi Md Accommodation At Kota Mil Stn; 1 Lump sum price worked out by the contractor for BUILDING WORKSas listed in Schedule ‘A’ Part-I representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES 2 Lump sum price worked out by the contractor for INTERNAL WATER SUPPLY as listed in Schedule ‘A’ Part-II representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES 3 Lump sum price worked out by the contractor for INTERNAL ELECTRIFICATIONas listed in Schedule ‘A’ Part-III representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES 4 Lump sum price worked out by the contractor for ROAD, PATH, CULVERT AND HARD STANDINGas listed in Schedule ‘A’ Part-IV representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES 5 Lump sum price worked out by the contractor for SEWAGE DISPOSALas listed in Schedule ‘A’ Part-V representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES 6 Lump sum price worked out by the contractor for AREA DRAINAGE as listed in Schedule ‘A’ Part-VI representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES 7 Lump sum price worked out by the contractor for FENCINGas listed in Schedule ‘A’ Part-VII representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES 8 Lump sum price worked out by the contractor for EXTERNAL WATER SUPPLYas listed in Schedule ‘A’ Part-VIII representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceof prepriced by the MES 9 Lump sum price worked out by the contractor for EXTERNAL ELECTRIFICATIONas listed in Schedule ‘A’ Part-IX representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceof prepriced by the MES 10 Lump sum price worked out by the contractor for LIGHTING PROTECTION as listed in Schedule ‘A’ Part-X representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES 11 Lump sum price worked out by the contractor for FIRE FIGHTINGas listed in Schedule ‘A’ Part-XI representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceof prepriced by the MES 12 Lump sum price worked out by the contractor for LIFT WORKas listed in Schedule ‘A’ Part-XII representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceof prepriced by the MES 13 Lump sum price worked out by the contractor for HOT WATER SUPPLYas listed in Schedule ‘A’ Part-XIII representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceof prepriced by the MES 14 Lump sum price worked out by the contractor for DG SETSas listed in Schedule ‘A’ Part-XIV representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceof prepriced by the MES 15 Lump sum price worked out by the contractor for SITE CLEARANCE, SITE DEVELOPMENTAND EARTH WORKas listed in Schedule ‘A’ Part-XV representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES 16 Sch A Part-XVI MISC ITEMS (TO BE QUOTED BY CONTRACTOR) Notes:(i) This schedule is not pre-priced by MES and the pre-priced rate indicated as Rs 0.00 under column 5 signifies this fact only. (ii) Excavation and earth work except for the items which categorically includes for same shall be measured and paid separately under SCH A PART-XVSITE CLEARANCE, SITE DEVELOPMENTAND EARTH WORK schedule). 17 INTERNAL WATER SUPPLYS&F for 15mm dia sink mixer (wall mounted) with 150mm long swivel spout,connecting legs and wall flangerswith complete accessories etc complete all as specified and directed.Make: CERA Cat Part No F2014511 / Hindware Cat Part No F690058 / Parryware Cat Part No G3335A1 or equivalent make as mentioned in Appx B. 18 S&F for 15mm dia single lever center hole basin mixerwith complete accessories etc complete all as specified and directed.Make: CERA Cat Part No F1015451 / Hindware Cat Part No F690012 / Parryware Cat Part No G4863A1 or equivalent make as mentioned in Appx B. 19 S&F for 15mm dia wall mixture with bend pipe for overhead showerwith complete accessories etc complete all as specified and directed.Make: CERA Cat Part No F2002401 / Hindware Cat Part No F330020 / Parryware Cat Part No G3316A1 or equivalent make as mentioned in Appx B. 20 INTERNAL ELECTRIFICATIONS&F ofmodular type 3 pin 20 A socket with SP MCB, conforming to IS 1293: 2005as specified in IS 732: 2019 etc complete all as specified and directed 21 S&F for modular type 1 module RJ-11 telephone socket with shutter etc complete all as specified and directed 22 S&F for modular type 1 module co-axial type TV socket etc complete all as specified and directed 23 S & F for 16 A, 230 V, 50 Hz, 2P MCB (B curve) MCB conforming to IS/IEC 60898-1-2002, having breaking capacity Icn = 10 kA, sliding bottom clamp, colour coded on/off indication on dolly, bi-connect IP 20 protected lower terminals and sliding shutters,IS 732: 2019 etc complete all as specified and directed 24 S & F for 25 A, 230 V, 50 Hz, 2P MCB (B curve) MCB conforming to IS/IEC 60898-1-2002, having breaking capacity Icn = 10 kA, sliding bottom clamp, colour coded on/off indication on dolly, bi-connect IP 20 protected lower terminals and sliding shutters,IS 732: 2019 etc complete all as specified and directed 25 S & F for 32 A, 230 V, 50 Hz, 2P MCB (B curve) MCB conforming to IS/IEC 60898-1-2002, having breaking capacity Icn = 10 kA, sliding bottom clamp, colour coded on/off indication on dolly, bi-connect IP 20 protected lower terminals and sliding shutters,IS 732: 2019 etc complete all as specified and directed 26 S & F for 40 A, 230 V, 50 Hz, 2P MCB (B curve) MCB conforming to IS/IEC 60898-1-2002, having breaking capacity Icn = 10 kA, sliding bottom clamp, colour coded on/off indication on dolly, bi-connect IP 20 protected lower terminals and sliding shutters,IS 732: 2019 etc complete all as specified and directed 27 S&F forSingle Phase Dual Source Pre Paid Meter, Class 1.0, RS485,10/60A Direct,with followingspecification as under : (i) Communication options:, RS485 and RF(ii)Three in one option:Integrate gas & waterupto 4 DI(iii) Programmable tariff for EB, DG and DI for automatic reduction of balance even server is offline(iv) Configurable Holidays,Happy hours to avoidload switching on Holidays/Night(v) Alarm notifications for low credit balance(vi) Eliminate tenantdisputes, meter tampering & manualtariff reading errors 28 S&F forThree Phase Dual Source Pre Paid Meter, Class 1.0, RS485, 5A CT operated,with followingspecification as under : (i) Communication options:, RS485 and RF(ii)Three in one option:Integrate gas & waterupto 4 DI(iii) Programmable tariff for EB, DG and DI for automatic reduction of balance even server is offline(iv) Configurable Holidays,Happy hours to avoidload switching on Holidays/Night(v) Alarm notifications for low credit balance(vi) Eliminate tenantdisputes, meter tampering & manualtariff reading errors 29 S&F of Sheet metal enclosure distribution board VTPN4 way, 415 voltdouble door powder coated, protection class IP-54 isolated neutral bar, mechanical impact strength IK 09 suitable for mounting MCB & MCCB DBs confirming to IS - 13032, IS-8623, BS EN60898 with min 200 Amp rating copper bus bar and grouting, fixing on wall with nut bolts washers proper with PCC works complete all as specified and directed 30 S&F of Sheet metal enclosure distribution board VTPN6 way, 415 voltdouble door powder coated, protection class IP-54 isolated neutral bar, mechanical impact strength IK 09 suitable for mounting MCB & MCCB DBs confirming to IS - 13032, IS-8623, BS EN60898 with min 200 Amp rating copper bus bar and grouting, fixing on wall with nut bolts washers proper with PCC works complete all as specified and directed 31 S&F of 160A, 4 pole moulded case circuit breaker (MCCB) with thermal magnetic trip unit (TMD), compression lug connectors, protection against overloads (Ir adjustable from 0.7- 1 X In), protection against short circuits (Isd adjustable from 5- 10 X Ir), inbuilt encapsulated double break roto active type instanteneous protection, earth fault leakage protection, etc. having Ics = 100% = Icu = 16 kA as per IEC 60947-2 and suitable for 3-Phase, 415 V, 50 Hz electric supply etc complete all as specified and directed by engineer-in-charge. 32 S&F for 12W LED Downlight having Luminous efficacy of > 100, input voltage range 140-270 V, input frequency 50-60 Hz etc complete all as specified and directed . 33 S&F for LED light fitting with high 10 watt 220 V AC decorative wall type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size etc complete all as specified and directed . 34 S&F for 10W LED bulk head light having Luminous efficacy of > 100, input voltage range 140-270 V, input frequency 50-60 Hz etc complete all as specified and directed. 35 Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 600 mm sweep. Min air delivery 115 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) etc complete all as specified and directed by engineer-in-charge. 36 Supply and fix Wall Mounting Fan, steel body AC single Phase, 230V,With Sweep Size, 200mm ; Motor Speed 84CMM, 3 blades, and frame and louvers etc complete all as specified and directed by engineer-in-charge. 37 Supply, installation, testing and commissioning of factory made, indoor cubical compartmental type BUILDING PANEL (TTA) of suitable size for short circuit, temperature rise, protective earth short circuit test and dielectric tests of required ratings, conforming to IEC 61439-1 & 2 and IEC 61641, having both sides openable with hinged double doors and locking arrangement, IP 42 protection made out of 2.0 mm thick mild steel CRCA sheet, supported and fixed on structural frame of angle iron of suitable size, including earthing stud, labelling, painting to all internal & external exposed steel surfaces with powder coating paint (7 tank process), duly fixed in ground with PCC foundation (1:2:4) type B1, with danger notice plate of 1.6 mm thick mild steel vitreous enameled (white) with letters, figures and conventional skull and bones in signal red colour suitable for 3- Phase, 4 Wire system, 500 V grade with necessary wiring, PVC sheathed stranded copper conductor of appropriate length and size, including fixing lugs, bolts, screws, etc. complete as specified and directed by engineer-in-charge.The BUILDING PANEL shall comprise of the following:(A) Bus bar Chamber(i) 01 Set (3L + N) of copper busbar of rated capacity 400A, covered with PVC insulated sleeves including insulator, nuts, bolts, etc. with complete connections. 38 (B) Incoming:- (i)320A, 415 V, Ics = 100% Icu = 16 kA, 50 Hz 4P MCCB, conforming to IEC 60947-2, having microprocessor based trip unit, adjustable overload setting (0.7 - 1 X In), adjustable short-circuit setting (5 - 10 X Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (ready, overload and pre-alarm & overload)- 01 No.(ii) Cl 1.0 multi-function meter capable of measuring V, A, F, PF, W/VA, Wh/VAh, Runhrs. Onhrs & interupts- 01 No.(iii) LED phase indicators (Red, Yellow, Blue)- 01 Set 39 (C) Outgoing:-(i)40A, 415 V, Ics = 100% Icu = 16 kA, 50 Hz 4P MCCB, conforming to IEC 60947-2, havingtrip unit, adjustable overload setting (0.7 - 1 X In), adjustable short-circuit setting (5 - 10 X Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (ready, overload and pre-alarm & overload)- 08 Nos(ii) LED phase indicators (Red, Yellow, Blue)- 08 Sets 40 SEWAGE DISPOSALS&F for DWCPE (SN8) 180mm outer dia and 163 inner dia of pipe for depth 0.70mm to 1.65m, laid on 150 mm thick bed (1:4:8)with excavation in any type of soil including manholes/drop manhole of standard sizemade of brick mosonary /RCC/Precast RCC with SFRC ventilating cover and frame,includes all items and activities to execute and make sewer line functionaletc complete all as specified and directed. 41 S&F for DWCPE (SN8) 200mm outer dia and 175 inner dia of pipe for depth 0.70mm to 1.65m, laid on 150 mm thick bed (1:4:8) with excavation in any type of soil including manholes/drop manhole of standard sizemade of brick mosonary /RCC/Precast RCC with SFRC ventilating cover and frame,includes all items and activities to execute and make sewer line functionaletc complete all as specified and directed. 42 S&F for DWCPE (SN8) 300mm outer dia and 260 inner dia of pipe for depth 1.65mm to 2.3m, laid on 150 mm thick bed (1:4:8) with excavation in any type of soil including manholes/drop manhole of standard sizemade of brick mosonary /RCC/Precast RCC with SFRC ventilating cover and frame,includes all items and activities to execute and make sewer line functionaletc complete all as specified and directed. 43 Supply, lay, commissioning, jointing and testing ofcentrifugally cast (spun) ductile iron pipes of 150mm bore class K-7 with spigot and socket ends conforming to IS 8329/2000, IS: 12288 : 1987 code of practice for laying in trenches complete all as specified and directed.Note: The rate quoted by contractor are inclusive of all type of Joints. 44 S&F forNonclog submersible (sewage disposal), pump set, electric driven 415 Volts 3 Phase 50 Hz, supply comprising of pump with cast iron impellors, submersible motor of suitable capacity, coupling, at discharge 3360 to 480 LPM and minimum discharge should be less than 480 LPM at minimum head 14 m.including chain pully block of two MT capacity 01 Noandsuitable arrangement for hanging the motor through chain of requirement of delivery of pump connected to main pipe line by suitabe HDPE pipe of size 150mm Dia for required length with necessary connection etc all as specified and as directed. 45 Supply,installing, testingand commissioningout door type LT feeder piller box of suitable size 750X750X450 mm, pedestal mounted, CPRI type test totally enclosed, dust and vermin proof, double leaf shutter in front and single leaf shutter in rear side made of 3.15 mm thick CRCA sheet, framing with 50 x50 x 6 mm thick MS angle iron and legs of size 0.5m long . duly fabricated and having proper locking arrangement in both front and rear door with 4 side slanting roof duly projected and paintedto both internal and External surfaces with powder coating paint in heatprocess of sheet and suitable for 415 volts, 50 Hz, 3 phase 4 wire system and comprising with and includingfollowing accessories and mounted on PCC Platform made out of100 mm thick PCC (1:3:6),0.45 Mtr all round the panel board etc complete with the following items :- 46 Incoming:- (i) Copper bus bar made up of copper strip100 amps duly mounted on bakelite insulatorssleevings of standard colour code - 01 Set. (04 No strips for Phases & Neutral)(ii) MCCB TPN 415 Volts,63 Amps, 50 Hz, breaking capacity 25 KA with fixed thermal & magnetic setting ( For Incomming ) - 01 No.Outgoing:-(i) MCB TP 415 volts 32 Amps, breaking capacity 16 KA with fixed thermal & magnetic setting ( For FPB2 ) - 03 Nos(2 nos for pump 1 nos for spare). (ii) FASD Starter for 15 HP Motor with single phase preventer, OLP and dry run protector- 02 Nos 47 (iii) Analogue type modular volt meterof range 0-500 volts -01 No(iv)Volt meter selector switch-01 No.(v) Analogue typeAmmeter of range 0-200 Amp-01 No(vi) Ammeter selector switch-01 No(set of three)(vii) Indicator lamp with integral circuit (230/240 volt) and cluster LED (Red, Orange, Blue) - 01 set(viii) CT 200/5 Amps - 3 Nos 48 Supply and FixingDI/CI special fittings of any size,type,radius angle,tapers increasing decreasing sockets,tees,tail piece and collars etc complete upto 200 mm dia etc complete all as specified and directed. 49 S&F forPVC insulated and sheathed 1100 volts grade flat type submersible 06 sqmm cable three core multi stranded conductor etc complete all as specified and directed . 50 M&L for Making drill hole by trenchless technologyof suitable size under road for laying pipe line of size150mm bore at 1 metre depth from the road level etc complete all as specified and directed.Note :- Drill hole (trenchless) shall be done without disturbing top surfaces of road by appropriate machine. 51 M&L for steel gate 5.45 m wide and 2.70 m height with RCC pillar including excavation in any type of soil, plastering, painting, etc complete all as specified and shown in TD/2008/101 sheet No 1/3 to 3/3 52 EXTERNAL WATER SUPPLY Supply, lay, commissioning, jointing and testing ofcentrifugally cast (spun) ductile iron pipes of 100mm bore class K-9 with spigot and socket ends conforming to IS 8329/2000, IS: 12288 : 1987 code of practice for laying in trenches complete all as specified and directed.Note: The rate quoted by contractor are inclusive of all type of Joints. 53 Supply, lay, commissioning, jointing and testing ofcentrifugally cast (spun) ductile iron pipes of 150mm bore class K-9 IS: 12288 : 1987 code of practice for laying in trenches complete all as specified and directed.Note: The rate quoted by contractor are inclusive of all type of Joints. 54 Supply and FixingDI/CI special fittings of any size,type,radius angle,tapers increasing decreasing sockets,tees,tail piece and collars etc complete upto 200 mm dia etc complete all as specified and directed. 55 Supply and fix CI foot valve with leather washer, ofsize 100 mm , lift and swing, single door, IS 4038 marked one with each pump suction line complete all as specified and directed. 56 M&L for construction of valve chamber of brick masonry from the top of surface with MS covers 3.15 mm thick and 40x40x6 mm MS angle with hinges for locking arrangement including excavation and earth works PCC (1:3:6) type C2 for foundation PCC bed/coping in cement concrete (1:2:4) type B1, plastering in CM 1:3 painting with two coats of synthetic enamel paint over a coat of red oxide primerfor the size of chamber 1200 mm x 1200 mm x 1200 mm (internal dimention) complete all as specified and directed. 57 Supply, install,commissioning and testing of Horizontal split case cetrifugal pump set 1450 RPM having an output of minimum 1100 LPM at a head of 45 mtr coupled to 3 phase 415 volt squirel case induction motor of adequate capacity complete all as ditected by Engr-in-charge with and including following :-(a) Necessary cable for interconnection between starter panel & pump set with 1100 volt rated copperinsulated unarmoured cable of minium 10 sqmm 3 core cable(b) Single phase preventer (current sensing type)(c) Necessary light grade GI pipe protection for cabling from pump set to LT panel.(d) Bourden pressure gauge.(e) MS pipe flanged type class B of size 100 mm bore upto foot valve from suction end of pump.(f) PCC foundation in type B-2, 1:2:4 using 20mm graded aggregate, 20cm above ground level and 30cm below grond level including grouting of eye bolts nut etc. for pump set of adequate size or as per manufacturers recommendations.Note: All other items/material requiredfor fixing pumpset shall be included in cost quoted.(ii) Foundation drawing shall be approved by GE/ Eng-In- Charge before fixing the pump set. 58 Supply, installations, testing and commissioning of factory made LT Indoor cubical typepanel boardhaving 150 Amp rated copper bus bar with neoprene rubber gasket and locking arrangement, dust,weather and verminproof , free standing, floor mounting type self ventilation with wire mesh,totally enclosed busbar chamber fully comparted type, front openable hinged independent door for each compartment with locking arrangement and common openable hinged door from rear side of suitable size made out of 2mm thick CRCA sheet duly painted with seven tank process,415 V,TPN,50Hz both side properly welded MS angular supported with chanel frame of size 50mm,at all vertical corner grouted in PCC 1:3:6 (Type-C1 using 20mm graded stone aggregate) and connecting the incomming/outgoing feeder by providing brass cable glands and Lugs complete all as specified and directed comprising of followings accessories:- 59 Incoming:- (i) MCCB 4 Pole 100 amps ,415 Volt of breaking capacity not less than 36 KA (Ics=100 % of Icu) with adjustable thermal Setting-01 No.Outgoing:-(i)MCCB 3 Pole 63 amps ,415 Volt of breaking capacity not less than36 KA (Ics=100 % of Icu) with adjustable thermal Setting - 02 Nos (ii) Single phase preventor -02 Nos(iii) On load Change over switch 4 pole of current raring 63 A (open execution type) - 01 No(iv)MCB SPN 10 Amp C curve, 10 KA capacity - 01 No(v) fully automatic Star-delta starter 15 HP or recommended by manufacturer of motor -02 Nos(vi) LED Indicator lamp (R,Y,B)- Set of Three.(vii) Multifunctional meterDigital type showing V,A,F,Pf,KW,KWH inbuilt selector switch with CT coiles for three phase -0 1No. 60 M&L for construction of header of ERW pipe having size dia 300 mm and length 2.5 m with two inlet connection of size 100 mm & three otlet connection having size 150 mm complete monting on RCC base/plinth etc complete all as specified and as directed by Engr-in-charge. 61 EXTERNAL ELECTRIFICATIONBoring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine for laying under ground pipe upto 100mm dia complete all as specified and directed.Note :- GI pipe shall be measured and paid separately. 62 Taking out existing HT XLPE U/G cables, 11000 V grade from trenches/ducts/ poles etc of size 120 Sq. mm 3 Core etccomplete all as specified and directed. 63 Dismantling and taking down existing transformer mounted on four pole structure and shifting to nearest suitable location including its fixing on newly constructed platform and making all connection, testing as per requirementetccomplete all as specified and directed. 64 Dismantling and taking down existing 4-pole structure etccomplete all as specified and directed. 65 Dismantling and taking down existing 03 Nos of LT Panels, refixing at specified locationincluding connecting etc complete all specified and directed. 66 Taking out existing LT XLPE U/G cables, 1100 V grade from trenches/ducts/ poles etc of size 240 Sq. mm 3.5 Core etc complete all as specified and directed. 67 Taking out existing LT XLPE U/G cables, 1100 V grade from trenches/ducts/ poles etc of size 185 Sq. mm 3.5 Core etc complete all as specified and directed. 68 Taking out existing LT XLPE U/G cables, 1100 V grade from trenches/ducts/ poles etc of size upto 95 Sq. mm 3.5 Core etc complete all as specified and directed.Note For item No. 57 to 63 :- The old material obtained from site shall be deposite by contractor in MES store yard without any extra cost as directed by GE. 69 M&L for construction of plateform of size 3500 x 3500 x 1200mm with brick construction in cement mortar 1:4 PCC (M-10 nominal mix) in foundation, 100mm thick RCC M-25 grade slab, with 8mm MS TMT bars 120mm c/c on bothway, brick masonary steps on one side XPM Jali fixed on angle iron 40x 40x6 mm post upto height of 8 feet above ground level and openable gate with locking arrangment including making provision for entry and exit of HT/LT cables and steps made to access to the top of plateform including plastering to bricks masonary complete including painting with 2 coats of whitewash on plastered surface and painting steel surface with 2 coats of red oxide primeretc complete all as specified and directed. 70 Supply & fix HT 11 KV, outdoor type gang operated air-break switch suitable for horizontal or vertical mounting rotating type complee with drop out fuse having 12 insulators of rating upto 200 Amps etc complete all as specified and directed. 71 Supply and fixing lightning arrestor HT 11 KV, 10 KA station class etc complete all as specified and directed. 72 Supply & errect 2 pole structure on 11 mtr PCC pole consisting of pole with anti-climbing device, PCC foundation & cross arms (Bracings) etc for one incoming and one out going. etc complete all as specified and directed. 73 Supply, installation, testing & commissioning of package type/unitised 11kV / 433 V Outdoor sub-station (CSS) ,315KVA made from G. I. enclosure complete as required conforming to IEC 62271-202 only and relevant IS specifications including K-10 Temperature Class as applicable for the rating, Internal Arc of 21 KA/1 Sec. IAC AB on 1:2:4 (1 cement :2 cores and : 4 Graded stone aggrregate of 40 mm nominal size) PCC foundation of suitable size extending 500 mm all around the outdoor enclosure and 1000 mm height (above ground level) complete with suitable sizes of GI Pipes for incoming/outgoing cables/earthing strips etc. and consisting of following complete as required. Angle iron frame of size 40x40x5mm NS all along the corner of the foundation CSS shall be from OEMs only . Licensed System Integrators of approved OEM are not allowed to supply .Package substation will have the following equipment :- 74 HT SWITCHGEAR11kV 630Amps 21KA/3 sec. Non-Extensible Ring Main Unit Compact switchgear consisting of1 no. fixed motorized Vacuum Circuit Breaker Moduleand 2 nos. fixed morotized Load break switch module in SF6 insulated stainless steel enclosure with series trip, self powered microprocessor based numerical over current and earth fault relay protection. HT RMU shall preferably have site replaceable bushings to have very less downtime in the event of bushing breakage and restoration can be done immediately without sending the RMU to OEM Works. Interconnection between HT Switchgear and primary of transformer shall be done through 1C x 3R x 95 sq.mm Aluminium XLPE cable. - 1 No.Vacuum Interrupter,RMU,LT Switchgear and CSS Enciosure shall be of same make to ensure life cycle optimization.(i)Microprocessor based IDMT Relay for Circuit Breakers - Self Powered along with series trip coil (Modbus RS485 complaint)(ii)Capacitive voltage indication fixed type system with LED for all feeder and FPI in all load break switch feeder.(iii)SF6 Gas pressure indicator.(iv)Operating sequence of VCB must be O-0.3Sec-CO-3 Mins-CO(v)Protection CT shall be minimum 40/1A ,2.5VA ,5P10. - 3 Nos 75 (vi)All modules of the RMU shall be suitable for cable termination of 3C x 300 sq.mm Al XLPE Cable, incoming cable termination is included within the scope of work - 1 SetTRANSFORMER315 KVA 11KV/433V DYN-11 Oil type, hermetically sealed energy efficiency level-2 transformer (BEE Star Rated-2) with corrugated wall, without conservator, type of design & Top Bushings for HT & LT with Off load tap switch of rating +5% to -5% @2.5%. Temp Rise - Oil/Winding 40/45 Deg cel. Losses (As per IS-1180 amended up to date)Max Losses @ 50% Load 955W and Max Losses @ 100% Load 2750 KW and Impedance of 4.5% (Subject to IS Tolerance (as per IS1180-2014) The transformer shall be conforming to IS: 2026 and IS: 1180(part-I). amended up to date. (i)01 No. Winding Temperature Indicator with Alarm and trip Contact.LT PANELLVS PANEL 500 AMPS 4 pole Aluminium BUSBAR (100% FOR PHASES AND 100% FOR NEUTRAL) - CURRENT DENSITY OF Aluminum as 1 A/sq.mm. ; LT panel made up of 1.5/2 mm thick CRCA sheet INCOMER CUM OUTGOINGS FROM TRANSFORMER(i)500 Amps 433V 4P 50Hz 50KA Fixed Manual Type Air Circuit Breaker (ACB)(ii) Multifunction meter with Modbus RS485 port & class 0.5 accuracy with Suitable CT. - 1 set 76 (iii)Hard wiring from each equipment inside CSS for scada connectivity (monitoring & control)to be brought to one set of TBs and a space for FRTU to be given. Supply of FRTU is not in scope. (iv)All Civil works such as PCC/RCC foundation, Plateform, Filling trench and pedestal etc as per CSS manufacturers recomandation are included in scope of work.OUTDOOR ENCLOSUREOutdoor type encloser of 1.5 mm (For non load bearing members) & 2.0 mm (For load bearing members) thickness having modular construction of Galvanised Sheet Steel in suitable design for better heat dissipation and providing robust. 77 construction. The Enclosure shall have IP54 degree of protection for HT & LT switchgear compartment & IP 23 degree of protection for transformer compartment. The enclosure exterior shall be painted with epoxy based powder paint (colour RAL 7032). Each compartment will be provided with the door and pad locking arrangement. The design of the enclosure should be type tested for suitablly handling any arcing inside the compartment for providing better safety to the operator. The compartment illumination lamp with door operated switch shall be provided for each compartment.Vacuum Interrupter,RMU,LT Switchgear, Multifunction meterand CSS Enciosure shall be of same make to ensure life cycle optimization. 78 Supply, installation, testing & commissioning of package type/unitised 11kV / 433 V Outdoor sub-station , (CSS) 400KVA made from G. I. enclosure complete as required conforming to IEC 62271-202 only and relevant IS specifications including K-10 Temperature Class as applicable for the rating, Internal Arc of 21 KA/1 Sec. IAC AB on 1:2:4 (1 cement :2 cores and : 4 Graded stone aggrregate of 40 mm nominal size) PCC foundation of suitable size extending 500 mm all around the outdoor enclosure and 1000 mm height (above ground level) complete with suitable sizes of GI Pipes for incoming/outgoing cables/earthing strips etc. and consisting of following complete as required. Angle iron frame of size 40x40x5mm NS all along the corner of the foundation CSS shall be from OEMs only . Licensed System Integrators of approved OEM are not allowed to supply.Package substation will have the following equipment :-HT SWITCHGEAR11kV 630Amps 21KA/3 sec. Non-Extensible Ring Main Unit Compact switchgear consisting of1 no. fixed motorized Vacuum Circuit Breaker Moduleand 2 nos. fixed morotized Load break switch module in SF6 insulated stainless steel enclosure with series trip, self powered microprocessor based numerical over current and earth fault relay protection. HT RMU shall preferably have site replaceable bushings to have very less downtime in the event of bushing breakage and restoration can be done immediately without sending the 79 RMU to OEM Works. Interconnection between HT Switchgear and primary of transformer shall be done through 1C x 3R x 95 sq.mm Aluminium XLPE cable. - 1 No.Vacuum Interrupter,RMU,LT Switchgear and CSS Enciosure shall be of same make to ensure life cycle optimization.(i)Microprocessor based IDMT Relay for Circuit Breakers - Self Powered along with series trip coil (Modbus RS485 complaint)(ii)Capacitive voltage indication fixed type system with LED for all feeder and FPI in all load break switch feeder.(iii)SF6 Gas pressure indicator.(iv)Operating sequence of VCB must be O-0.3Sec-CO-3 Mins-CO(v)Protection CT shall be minimum 40/1A ,2.5VA ,5P10. - 3 Nos.(vi)All modules of the RMU shall be suitable for cable termination of 3C x 300 sq.mm Al XLPE Cable, incoming cable termination is included within the scope of work - 1 Set 80 TRANSFORMER400 KVA 11KV/433V DYN-11 Oil type, hermetically sealed energy efficiency level-2 transformer (BEE Star Rated-2) with corrugated wall, without conservator, type of design & Top Bushings for HT & LT with Off load tap switch of rating +5% to -5% @2.5%. Temp Rise - Oil/Winding 40/45 Deg cel. Losses (As per IS-1180 amended up to date)Max Losses @ 50% Load 1150W and Max Losses @ 100% Load 3330 KW and Impedance of 4.5% (Subject to IS Tolerance (as per IS1180-2014) The transformer shall be confirming to IS: 2026 and IS: 1180(part-I). amended up to date. (i)01 No. Winding Temperature Indicator with Alarm and trip Contact.LT PANELLVS PANEL 630 AMPS 4 pole Aluminium BUSBAR (100% FOR PHASES AND 100% FOR NEUTRAL) - CURRENT DENSITY OF Aluminum as 1 A/sq.mm. ; LT panel made up of 1.5/2 mm thick CRCA sheet INCOMER CUM OUTGOINGS FROM TRANSFORMER(i)630 Amps 433V 4P 50Hz 50KA Fixed Manual Type Air Circuit Breaker (ACB) (ii) Multifunction meter with Modbus RS485 port & class 0.5 accuracy with Suitable CT. - 1 set 81 (iii)Hard wiring from each equipment inside CSS for scada connectivity (monitoring & control)to be brought to one set of TBs and a space for FRTU to be given. Supply of FRTU is not in scope. (iv)All Civil works such as PCC/RCC foundation, Plateform, Filling trench and pedestal etc as per CSS manufacturers recomandation are included in scope of work.OUTDOOR ENCLOSUREOutdoor type encloser of 1.5 mm (For non load bearing members) & 2.0 mm (For load bearing members) thickness having modular construction of Galvanised Sheet Steel in suitable design for better heat dissipation and providing robustconstruction. The Enclosure shall have IP54 degree of protection for HT & LT switchgear compartment & IP 23 degree of protection for transformer compartment. The enclosure exterior shall be painted with epoxy based powder paint (colour RAL 7032). Each compartment will be provided with the door and pad locking arrangement. The design of the enclosure should be type tested for suitablly handling any arcing inside the compartment for providing better safety to the operator. The compartment illumination lamp with door operated switch shall be provided for each compartment.Vacuum Interrupter,RMU,LT Switchgear, Multifunction meterand CSS Enciosure shall be of same make to ensure life cycle optimization. 82 Supply, installations, testing and commissioning factory made out door cubical typeLT panel board dust and verminproof , free standing, floor mounting type mounted on and incluidng1:3:6 PCC foundation as requried at site and of fabricated by 3.0mm thick CRCA Sheet over MS 50 X 50 x 6 mm thick angle iron frameof requriedtype for support with double door both sides open type with necessarylockingarrangement with sloppedroof on top duly paintedwith two coatsof powder coated semense gray paint complete and having separatedoors inside for accomodatingall incomming / outgoing feeders of suitable sizes all as specified and directedby Engr-in- Charge(Panel 1 - Near mains transformer GTC Area):- 83 INCOMING :-(i) S&F ACB 4 Pole 630 amps ,415 Volt electrical drawout type of breaking capacity not less than50 KA (Ics=100 % of Icu) with Adjustable TM Range (Optium 2.0) - 01 Nos Incommer.(ii) Aluminium electrolite Busbar 750 Amps current rating duly sleev insulated for set of 3 phase, 4 wire system and branch connection of suitable size of outgoing current rating of MCB/MCCBsOUTGOING:-(i) S&F MCCB 4 Pole 315 amps ,415 Volt of breaking capacity not less than16 KA (Ics=100 % of Icu) with Adjustable TM Range (Optium 2.0) - 01 No (for LT distribution panels of block )(ii) S&F MCCB 4 Pole 200 amps ,415 Volt of breaking capacity not less than16 KA (Ics=100 % of Icu) with adjustable thermal Setting (Optium 2.0) -02 Nos(for LTP Pump Motor, lift, fire fighting, stree light etc + spare).(iii)Digital Ammeter 0-500 A with selector switch & CTs of suitable capacity - 01 set.(ivDigital volt meter 0-400 V with selector switch - 01 No.(v)LED Indicating Lamps R,Y,B - 01 Set of three 84 Supply, installations, testing and commissioning factory made out door cubical typeLT panel board dust and verminproof , free standing, floor mounting type mounted on and incluidng1:3:6 PCC foundation as requried at site and of fabricated by 3.0mm thick CRCA Sheet over MS 50 X 50 x 6 mm thick angle iron frameof requriedtype for support with double door both sides open type with necessarylockingarrangement with sloppedroof on top duly paintedwith two coatsof powder coated semense gray paint complete and having separatedoors inside for accomodatingall incomming / outgoing feeders of suitable sizes all as specified and directedby Engr-in- Charge:- (Panel 2 - Near Chambal Vihar Main Tfr Panel):-INCOMING :-(a) S&F MCCB 4 Pole 500 amps ,415 Volt of breaking capacity not less than36 KA (Ics=100 % of Icu) with Adjustable TM Range (Optium 2.0) - 01 Nos Incommer.(b) Aluminium electrolite Busbar 600 Amps current rating duly sleev insulated for set of 3 phase, 4 wire system and branch connection of suitable size of outgoing current rating of MCB/MCCBs 85 OUTGOING:-(i) S&F MCCB 4 Pole 250 amps ,415 Volt of breaking capacity not less than25 KA (Ics=100 % of Icu) with Adjustable TM Range (Optium 2.0) - 01 No (for LT distribution panels of blocks)(ii) S&F MCCB 4 Pole 160 amps ,415 Volt of breaking capacity not less than25 KA (Ics=100 % of Icu) with adjustable thermal Setting (Optium 2.0) -02 Nos(for LTP Pump Motor, lift, fire fighting, stree light etc + spare).(iii)Street light timer using Power contactor 32 Amps, (1-NO) 3 pole, 415Volt, DIN Type digital programable time switch 230V AC, Auto/Manual selector switch, MCB 4 pole 25 Amps C-range, ON/OFF indicator all prewired and making provision for fixing outgoing cables- 01 Set complete.(iv)Digital Ammeter 0-500 A with selector switch & CTs of suitable capacity - 01 set.(v)Digital volt meter 0-400 V with selector switch - 01 No.(vi)LED Indicating Lamps R,Y,B - 01 Set of three 86 Supply, installations, testing and commissioning factory made out door cubical typeLT panel board dust and verminproof , free standing, floor mounting type mounted on and incluidng1:3:6 PCC foundation as requried at site and of fabricated by 3.0mm thick CRCA Sheet over MS 50 X 50 x 6 mm thick angle iron frameof requriedtype for support with double door both sides open type with necessarylockingarrangement with sloppedroof on top duly paintedwith two coatsof powder coated semense gray paint complete and having separatedoors inside for accomodatingall incomming / outgoing feeders of suitable sizes all as specified and directedby Engr-in- Charge:- (Panel 1A - LT PANEL FOR 3 X BLOCKS GTC):-INCOMING :-(i) S&F MCCB 4 Pole 315 amps ,415 Volt of breaking capacity not less than36 KA (Ics=100 % of Icu) with Adjustable TM Range (Optium 2.0) - 01 Nos Incommer.(ii) Aluminium electrolite Busbar 400 Amps current rating duly sleev insulated for set of 3 phase, 4 wire system and branch connection of suitable size of outgoing current rating of MCB/MCCBs 87 OUTGOING:-(i) S&F MCCB 4 Pole 125 amps ,415 Volt of breaking capacity not less than25 KA (Ics=100 % of Icu) with Adjustable TM Range (Optium 2.0) - 04 No (for 3 X Blocks+spare)(ii) Digital Ammeter 0-500 A with selector switch & CTs of suitable capacity - 01 set.(iii)Digital volt meter 0-400 V with selector switch - 01 No.(iv)LED Indicating Lamps R,Y,B - 01 Set of three 88 Supply, installations, testing and commissioning factory made out door cubical typeLT panel board dust and verminproof , free standing, floor mounting type mounted on and incluidng1:3:6 PCC foundation as requried at site and of fabricated by 3.0mm thick CRCA Sheet over MS 50 X 50 x 6 mm thick angle iron frameof requriedtype for support with double door both sides open type with necessarylockingarrangement with sloppedroof on top duly paintedwith two coatsof powder coated semense gray paint complete and having separatedoors inside for accomodatingall incomming / outgoing feeders of suitable sizes all as specified and directedby Engr-in- Charge:- (Panel 2A - LT PANEL FOR 2 X BLOCKS CHAMBAL VIHAR):-INCOMING :-(i) S&F MCCB 4 Pole 250 amps ,415 Volt of breaking capacity not less than36 KA (Ics=100 % of Icu) with Adjustable TM Range (Optium 2.0) - 01 Nos Incommer.(ii) Aluminium electrolite Busbar 400 Amps current rating duly sleev insulated for set of 3 phase, 4 wire system and branch connection of suitable size of outgoing current rating of MCB/MCCBs 89 OUTGOING:-(i) S&F MCCB 4 Pole 125 amps ,415 Volt of breaking capacity not less than25 KA (Ics=100 % of Icu) with Adjustable TM Range (Optium 2.0) - 03 No (for 3 X Blocks+spare)(ii) Digital Ammeter 0-500 A with selector switch & CTs of suitable capacity - 01 set.(iii)Digital volt meter 0-400 V with selector switch - 01 No.(iv)LED Indicating Lamps R,Y,B - 01 Set of three 90 Supply, installations, testing and commissioning factory made out door cubical typeLT panel board dust and verminproof , free standing, floor mounting type mounted on and incluidng1:3:6 PCC foundation as requried at site and of fabricated by 3.0mm thick CRCA Sheet over MS 50 X 50 x 6 mm thick angle iron frameof requriedtype for support with double door both sides open type with necessarylockingarrangement with sloppedroof on top duly paintedwith two coatsof powder coated semense gray paint complete and having separatedoors inside for accomodatingall incomming / outgoing feeders of suitable sizes all as specified and directedby Engr-in- Charge:- (Panel 1B & 2B):-INCOMING :-(i) S&F MCCB 4 Pole 200 amps ,415 Volt of breaking capacity not less than25 KA (Ics=100 % of Icu) with Adjustable TM Range-01 No incoming.(ii) Aluminium Electrolite Busbar 300Amps current rating duly sleev insulated for set of 3 phase, 4 wire system and branch connection of suitable size of outgoing current rating of MCB/MCCBs-01Set 91 OUTGOING:-(i) MCCB 4 pole 63 Amp, 415 V, 16 KA, C-series. - 01 Nos (for PH Panel)(ii) MCCB 4 pole 40 Amp, 415 V, 16 KA, C-series- 02 Nos (sewage PH +spare).(iii) MCB TPN 25Amp, 230 V, 10 KA, C-series - 07 Nos (Lifts+fire fighting+Street lights)(iv)Street light timer using Power contactor 25 Amps, (1-NO) 3 pole, 415Volt, DIN Type digital programable time switch 230V AC, Auto/Manual selector switch, MCB 4 pole 25 Amps C-range, ON/OFF indicator all prewired and making provision for fixing outgoing cables- 01 Set complete.(v) Digital Ammeter 0-150 A with selector switch & CTs of suitable capacity - 01 set.(vi) Digital volt meter 0-500 V with selector switch - 01 No. (vii) On load Change over switch 4 pole of current raring 63-100 A (open execution type) - 01 No.(viii)LED Indicating Lamps R,Y,B - 01 Set of three 92 Supply, installations, testing and commissioning factory made out door cubical typeLT panel board dust and verminproof , free standing, floor mounting type mounted on and incluidng1:3:6 PCC foundation as requried at site and of fabricated by 3.0mm thick CRCA Sheet over MS 50 X 50 x 6 mm thick angle iron frameof requriedtype for support with double door both sides open type with necessarylockingarrangement with sloppedroof on top duly paintedwith two coatsof powder coated semense gray paint complete and having separatedoors inside for accomodatingall incomming / outgoing feeders of suitable sizes all as specified and directedby Engr-in- Charge:- (Panel D - DOE Area):-INCOMING :-(i) S&F MCCB 4 Pole 100 amps ,415 Volt of breaking capacity not less than16 KA (Ics=100 % of Icu) with adjustable thermal Setting (Optium 2.0)-01 No incoming.(ii) Aluminium Electrolite Busbar 150 Amps current rating duly sleev insulated for set of 3 phase, 4 wire system and branch connection of suitable size of outgoing current rating of MCB/MCCBs-01Set 93 OUTGOING:-(i) MCCB 4 pole 63 Amp, 415 V, 16 KA, C-series - 02 Nos (for Bldg + Spare)(ii) MCB SPN 10 Amp, 415 V, 10 KA, C-series - 02 Nos (Garages + Spare).(iii) MCB SPN 10 Amp, 230 V, 10 KA, C-series - 02 Nos (Security light + Spare)(iv) Digital Ammeter 0-150 A with selector switch & CTs of suitable capacity - 01 set.(v) Digital volt meter 0-500 V with selector switch - 01 No.(vi)LED Indicating Lamps R,Y,B - 01 Set of three 94 M&L for factory made busbar box 750 Amps rated Aluminium busbar, 3 phase, 4 wire, 415 Volt of size not less than 300mm x 200mm x 100mm, fabricated using 1.6mm MS sheet, duly painted with smoke gray powder coated over a coat of red oxide primer suitable for fixing on wal by using wall fastners 10mm dia and making necessary incomming and outgoing connection of electric cables using aluminium lugs etc complete all as specified and diected. 95 M&L for factory made busbar box 600 Amps rated Aluminium busbar, 1 phase, 245 Volt, size not less than 200mm x 150mm x 100mm, fabricated using 1.6mm MS sheet, duly painted with smoke gray powder coated over a coat of red oxide primer suitable for fixing on wall by using wall fastners 10mm dia and making necessary incomming and outgoing connection of electric cables using aluminium lugs etc complete all as specified and diected. 96 Supply and fixing poly carbonatejunction box , weather and vermin proof of size 250X250X160 including provn of 4 Nos aluminium strip 25x3.15 mm size bus bar single phase and neutral suitabely mounted on bus bar insulators ,including one No. MCB SP 6 Amps for light control,drilling of holes.Provn of suitable size of GI nuts, bolts, double washer and FI clamps ofsuitable sizefor taking connections and fixing on LT steel tubular poles complete with locking arrangementcomplete all as specified and directed. 97 Supply and connecting three core cord flexible wire, copper conductor multistranded, PVC insulated and overall PVC sheathed of size 1.5Sqmm 1100 Volt , draw through LT steel tubular polesfor connection to street light from junction boxetc complete all as specified & directed. 98 S&F for Cable route indicator, duly engraved with LT CABLE 1100 VOLT on cast iron round plate 150 mm dia with provision of 500 mm long (minimum) single leg/stand of flat iron 40 x 5 mm, welded/riveted on back side of plate, fixed and grouted in position with PCC 1:3:6 type C-1, block of suitable size etc complete all as specified & directed. 99 M&L for Precast PCC (1:2:4) type B-1 cable path indicators of size 300x100x500mm rounded top having engraved in capital letters HT Cable embedded in position in PCC(1:3:6) Type C-1, using necessary formwork and including provision of two coats of cement base paint on exposed concrete surface and writing HT Cable in black synthetic enamel paint etc complete all as specified & directed. 100 M&L fordecorative LED post top lantern (PTL) luminior with die cast aluminium spigot, spun aluminium powder coated top cover clear/opal acralic difusser LED light fitting of 25 watts including LED lamp etc complete all as specified & directed. 101 M& L for shifting of 33 KV HT cable to a safe distance from proposed building, supply, laying, testing & commisioning of 33 KV cable in replacement with new as per estimate provided by State electricity deptetc etc complete all as specified & directed. 102 FIRE FIGHTINGS&F forAutomatic air release valve 50mm dia suitable for domestic water with 25mm gun metal stop valveetc complete all as specified & directed. 103 S&F forbranch pipe with nozzle of 20mm dia for hose reel conforming to IS 8090etc complete all as specified and directed. 104 S&F forfix Valve, stop, screwed, 25 mmdia pipeetc complete all as specified and directed. 105 S&F for6 kg capacity Multipurpose dry chemical powder (ABC) type(IS-15683) fire extinguishers consisting of welded MS cylindrical body fabricated from 1.6 mm MS sheet internally protected with anticorrosive treatment and hydraucally tested. Extinguisher externally painted with red enamel and fixed to wall with bracket complete with initial filled/charged .etc complete all as specified and directed. 106 S&F forCO2 type fire extinguisher of 3 Kgs capacity with steel cylinder with a discharge valve and confirming to IS : 15683.Extinguisher shall be painted with red enamel apint and fixed to wall with bracket etc complete all as specified and directed. 107 S&F for9 Ltr capacity Foam type(IS-15683) fire extinguishers consisting of welded MS cylindrical body fabricated from 1.6 mm MS sheet internally protected with anticorrosive treatment and hydraucally tested. Extinguisher externally painted with red enamel and fixed to wall with bracket complete with initial filled/chargedetc complete all as specified and directed. 108 S&F fortesting of Star-Delta starter Panel for fire fighting pump motor etc complete all as specified and directed. 109 Supply, installation, testing & commissioning ofFIRE SIGNAGES for indication/information of fire exit, alarm panel, fire extinguishers fire axe, hose reel, hydrents, lifts of size 300mmx100mm etc complete all as specified and directed. 110 DG SETSSupply, installation, commissioning and testing complete of Manufacturer of OEM (Original Eqpt Manufacturer) manufactured and tested static Diesel Engine driven generating set capable of delivering 180 KVA continuous rating, (10% overload for 1 hour in 12 hours of operation), 415 volts (AC 3 phase, 4 wire system of supply), 50 Hz at power factor 0.8 minimum. The DG set shall consist of a diesel engine coupled directly to a matching alternator, and mounted on Dunlop metallastik foundation pads on a common base frame and thereafter installed in the CPCB approved acoustic enclosure complete with control panel standardised by manufacturer, fuel tank with mounting arrangement and inlet, outlet, return oil arrangement, flexible exhaust pipe complete all as specified and directed and shall include comprise of the following :- 111 (A) Engine (prime mover) : Diesel engine 1500 RPM, of suitable HP as recommended by manufacturer, water cooled, turbocharged, 12 volts electric battery start, complete with fly wheel and torsional vibration damper, rediator and all standard fittings/fixtures as per standard manufacturing practices and including suitable instrument panel with RPM meter, lub oil temp and pressure gauge, water temp gauge and frequency meter (digital type), battery charging ammeter and fuses, and also including self starter (12V), battery charging alternator, fuel tank etc and complete with HWT and LLOP alarm and shut down safeties complete with first fill of Lub oil and Coolent. (B) Alternator : AC alternator, brushless, 415V AC 50 Hz, 3 phase, 4 wire type, rated for continuous output of 63 KVA, PF 0.8 (lag), 1500 RPM insulation class H; enclosure SPDP (IP 22/23), self excited & self regulated with AVR for + 1% voltage regulation, coupled directly/suitably to and to match the above engine and conforming to BS 5000/IS 4722. 112 (C) Dunlop Metallastik anti-vibration of pads for mounting engine - alternator assembly on the base frame/plate.(D) Base plate : Made out of structural steel as per manufacturers recommended design/specifications.(E) Enclosure : Provision of an integral type, approved/certified acoustic enclosure as per latest CPCB norms, for the DG set to restrict the noise level to 75 DB (A) at one metre and ensure that temperature rise within the canopy shall not exceed 5 - 7 degree celsius, It shall be made of 16 SWG CRCA MS sheet with powder-coated finish on outside and high quality noise absorbent and fire retardant grade acuoustic insulation material duly provided with EPDN gasket lining. There shall be four hinged doors out of which one shall be with a glass window.(i)Silencer : Absorption type, non-resistance, residential.(ii) Internal wiring with PVC copper conductor cables, IS 694 marked, FRLS in conduit and suitable light fittings.(iii)Fuel tank to be provided as per OEM specificaton.(iv)Safeties for high enclosure temperature and emergency shut-down from outside.(v) 1No 12V of suitable AH lead acid batteries and adequate size copper conductor cable leads, housed on & including suitable size MS angle iron frame and necessary clamps, nuts, bolts, washers all as required & as per manufacturer design/specifications.(F) Control panel : Control panel made out of 14 gauge CRCA sheet, powder coated and shall consists of the following: - 113 (i) Ps 0500 Controller (ii) Aluminium Bus bars with suitable capacity incoming & outgoing terminals.(iii) Indicating lamps for load on and set running (iv) Instrument fuses duly wired and ferruled. (v) Circuit breaker(MCCB) of suitable rating with overload and short circuit protections. Note: To be mounted inside enclosure. (G) Automatic mains failure (AMF) control panel fabricated from CRCA sheet steel of thickness not less than 3.15 mm, suitable for outdoor installation (including CPRI type test certified), dust & vermin proof, protection class I P-54 suitable for 415 volts, 3 phase, 4 wire, 50 Hz, AC supply system with adequate layers of power coating floor mounting type with front opening, the AMF panel shall comprise the following indicating instruments & switches:- 114 AC voltmeter - 01NoVoltmeter selector switch OFF/RY/YB/BR - 01NoFrequency meter - 01NoAC voltmeter of suitable scale - 01NoAmmeter selector switch OFF/R/Y/B - 01NoCurrent transformers of suitable ratio - 01NoBattery charger consisting of - 01No(aa) Transformer / Rectifier unit (bb) DC ammeter /DC voltmeter(cc) Charging rate selector switch OFF/Trickle/BoostMains supply air break contactor, 3 pole of suitable raing - 01NoAlternator air break contactor, 3 pole of suitable rating and provided with a separate overload relay for overload protection - 01NoMains supply voltage monitor - 01NoSet of DC control relays and timers - 01NoSet of push buttons, START, STOP, ACKNOWLEDGE, RESET, MAINS BREAKER, CLOSE/TRIP, ALTERNATOR BREAKER CLOSE / TRIP - 01No 115 01 Set of indicating lamps for the following :-LOAD ON MAINS, LOAD ON SET, SET FAILS TO START, LOW OIL PRESSURE, HIGH TEMPERATURE ALARM, HIGH TEMPERATURE TRIP, ALTERNATOR OVERLOAD.Audio - alarm hooter - 01NoKWH meter - One Set of Bus bars - 01NoThe control cubicle will be furnished complete with the necessary control circuit fuses, etc. and will have provisions for making incoming and outgoing connections.KW meter - 01Noset of bus bar - 01NoThe control cubical will be furnished complete with the necessary control circuit fuse etc and will have provision for making incoming and outgoing connectionsOne - set of bus bar - 01NoThe control cubicle will be furnished complete with the necessary control circuit fuses, etc. and will have provisions for making incoming and outgoing connections.Note :(i) In case AMF panel included instead of Standard Control Panel, then Battery charging alternator with inbuilt regulator and battery charging ammeter should be deleted from engine specifications since Battery charger included under AMF Panel specifications. 116 (ii) Platform : PCC foundation /plinth/baseshall be provided as per drawing No: TD/2010/109, Sheet No 1/1.(iii) Tool kit, Operation and Maintenance catalogue, 1 year spare part list, overhauling manuals, guarantee card etc shall be provided as per manufacturer standard practices. 117 Supply, installation, commissioning and testing complete of Manufacturer of OEM (Original Eqpt Manufacturer) manufactured and tested static Diesel Engine driven generating set capable of delivering 125 KVA continuous rating, (10% overload for 1 hour in 12 hours of operation), 415 volts (AC 3 phase, 4 wire system of supply), 50 Hz at power factor 0.8 minimum. The DG set shall consist of a diesel engine coupled directly to a matching alternator, and mounted on Dunlop metallastik foundation pads on a common base frame and thereafter installed in the CPCB approved acoustic enclosure complete with control panel standardised by manufacturer, fuel tank with mounting arrangement and inlet, outlet, return oil arrangement, flexible exhaust pipe complete all as specified and directed and shall include comprise of the following :- 118 (A) Diesel engine 1500 RPM, of suitable HP as recommended by manufacturer, water cooled, turbocharged, 12 volts electric battery start, complete with fly wheel and torsional vibration damper, rediator and all standard fittings/fixtures as per standard manufacturing practices and including suitable instrument panel with RPM meter, lub oil temp and pressure gauge, water temp gauge and frequency meter (digital type), battery charging ammeter and fuses, and also including self starter (12V), battery charging alternator, fuel tank etc and complete with HWT and LLOP alarm and shut down safeties complete with first fill of Lub oil and Coolent. (B) Alternator : AC alternator, brushless, 415V AC 50 Hz, 3 phase, 4 wire type, rated for continuous output of 63 KVA, PF 0.8 (lag), 1500 RPM insulation class H; enclosure SPDP (IP 22/23), self excited & self regulated with AVR for + 1% voltage regulation, coupled directly/suitably to and to match the above engine and conforming to BS 5000/IS 4722. (C)Dunlop Metallastik anti-vibration of pads for mounting engine - alternator assembly on the base frame/plate. 119 (D) Base plate : Made out of structural steel as per manufacturers recommended design/specifications.(E) Enclosure : Provision of an integral type, approved/certified acoustic enclosure as per latest CPCB norms, for the DG set to restrict the noise level to 75 DB (A) at one metre and ensure that temperature rise within the canopy shall not exceed 5 - 7 degree celsius, It shall be made of 16 SWG CRCA MS sheet with powder-coated finish on outside and high quality noise absorbent and fire retardant grade acuoustic insulation material duly provided with EPDN gasket lining. There shall be four hinged doors out of which one shall be with a glass window.(i)Silencer : Absorption type, non-resistance, residential.(ii) Internal wiring with PVC copper conductor cables, IS 694 marked, FRLS in conduit and suitable light fittings.(iii)Fuel tank to be provided as per OEM specificaton.(iv)Safeties for high enclosure temperature and emergency shut-down from outside.(v) 1Nos 12V of suitable AH lead acid batteries and adequate size copper conductor cable leads, housed on & including suitable size MS angle iron frame and necessary clamps, nuts, bolts, washers all as required & as per manufacturer design/specifications. 120 (F) Control panel : Control panel made out of 14 gauge CRCA sheet, powder coated and shall consists of the following: - (i) Ps 0500 Controller (ii) Aluminium Bus bars with suitable capacity incoming & outgoing terminals.(iii) Indicating lamps for load on and set running(iv) Instrument fuses duly wired and ferruled. (v) Circuit breaker(MCCB) of suitable rating with overload and short circuit protections. Note: To be mounted inside enclosure. (G) Automatic mains failure (AMF) control panel fabricated from CRCA sheet steel of thickness not less than 3.15 mm, suitable for outdoor installation (including CPRI type test certified), dust & vermin proof, protection class I P-54 suitable for 415 volts, 3 phase, 4 wire, 50 Hz, AC supply system with adequate layers of power coating floor mounting type with front opening, the AMF panel shall comprise the following indicating instruments & switches:- AC voltmeter -01 NoVoltmeter selector switch OFF/RY/YB/BR - 01 No 121 Frequency meter - 01 NoAC voltmeter of suitable scale - 01 NoAmmeter selector switch OFF/R/Y/B - 01 NoCurrent transformers of suitable ratio - 01 NoBattery charger consisting of - 01 No(aa) Transformer / Rectifier unit (bb) DC ammeter /DC voltmeter(cc) Charging rate selector switch OFF/Trickle/BoostMains supply air break contactor, 3 pole of suitable raing - 01 NoAlternator air break contactor, 3 pole of suitable rating and provided with a separate overload relay for overload protection - 01 NoMains supply voltage monitor - 01 NoSet of DC control relays and timers - 01 NoSet of push buttons, START, STOP, ACKNOWLEDGE, RESET, MAINS BREAKER, CLOSE/TRIP, ALTERNATOR BREAKER CLOSE / TRIP - 01 No01 Set of indicating lamps for the following :-LOAD ON MAINS, LOAD ON SET, SET FAILS TO START, LOW OIL PRESSURE, HIGH TEMPERATURE ALARM, HIGH TEMPERATURE TRIP, ALTERNATOR OVERLOAD.Audio - alarm hooter - 01NoKWH meter - One Set of Bus bars - 01NoThe control cubicle will be furnished complete with the necessary control circuit fuses, etc. and will have provisions for making incoming and outgoing connections. 122 KW meter - 01Noset of bus bar - 01NoThe control cubical will be furnished complete with the necessary control circuit fuse etc and will have provision for making incoming and outgoing connectionsOne - set of bus bar - 01NoThe control cubicle will be furnished complete with the necessary control circuit fuses, etc. and will have provisions for making incoming and outgoing connections.Note :(i) In case AMF panel included instead of Standard Control Panel, then Battery charging alternator with inbuilt regulator and battery charging ammeter should be deleted from engine specifications since Battery charger included under AMF Panel specifications. 123 (ii) Platform : PCC foundation /plinth/baseshall be provided as per drawing No: TD/2010/109, Sheet No 1/1.(iii) Tool kit, Operation and Maintenance catalogue, 1 year spare part list, overhauling manuals, guarantee card etc shall be provided as per manufacturer standard practices. 124 Supply, installations, testing of electric chimney of size 60cm havingsuction capacity of 1200 cum per hour with filterless technology sealed motor and insulationfor oil deposit and water vapour alongwith self autoclean feature after 30 cycles of operation and minimum 5 year warranty etc etc complete all as specified and directed.
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 5
Contract Date: Jun 08, 2026 Contract Value : 3.52 Lakh
Government Departments No of Bidders 1
Uttar Pradesh View Result →
3.
Defence #11167640 AOC
Tender For Provision Of Single Men Barracks Including Cook House For Agniveers At Brc, Danapur.; 1 SCHEDULE A Part-I (Building/Structures) (To be quoted by the tenderer) 2 Item No 01 A : Design and construction of 180 ORs SM BarrackComplete allspecified in soil bearing capacity report, design basis report, drawings and tender documents. 3 Item No 01 B: Design and construction of Dinning Hall Complete allspecified in soil bearing capacity report, design basis report, drawings and tender documents. 4 Item No 01C : Design and construction of Cook House Complete allspecified in soil bearing capacity report, design basis report, drawings and tender documents. 5 Sch A Part-II (Internal Electrification)Lump sum price worked out by the contractor for (Internal Electrification) as listed in Schedule A Part-II against the lump sum price inserted by the MES. 6 Sch A Part-III (External Electric Supply)Lump sum price worked out by the contractor for (External Electric Supply) as listed in Schedule A Part-III against the lump sum price inserted by the MES. 7 Sch A Part-IV(External Water supply)Lump sum price worked out by the contractor for (External Water supply) as listed in Schedule A Part-IV against the lump sum price inserted by the MES. 8 Sch A Part-V(Road, Path Curvert)Lump sum price worked out by the contractor for (Road, Path Curvert)as listed in Schedule A Part-V against the lump sum price inserted by the MES. 9 Sch A Part-VI (Air Conditioning)Lump sum price worked out by the contractor for (Air Conditioning) as listed in Schedule A Part-VI against the lump sum price inserted by the MES. 10 Sch A Part-VII(Refrigeration System)Lump sum price worked out by the contractor for (Refrigeration System) as listed in Schedule A Part-VII against the lump sum price inserted by the MES. 11 Sch A Part-VIII((FIRE FIGHTING SYSTEM(DOWN COMMER) & FIRE ALARM SYSTEM)Lump sum price worked out by the contractor for ((FIRE FIGHTING SYSTEM(DOWN COMMER) & FIRE ALARM SYSTEM) as listed in Schedule A Part-VIII against the lump sum price inserted by the MES. 12 Sch A Part-IX(Demolition of Bld (B/R) Lump sum price worked out by the contractor for (Demolition of Bld (B/R)as listed in Schedule A Part-IX against the lump sum priceinserted by the MES. 13 Sch A Part-X(Sewage Disposal) Lump sum price worked out by the contractor for (Sewage Disposal)as listed in Schedule A Part-X against the lump sum priceinserted by the MES. 14 Sch A Part-XI(Area Drainage)Lump sum price worked out by the contractor for (Area Drainage) as listed in Schedule A Part-XI against the lump sum price inserted by the MES. 15 Sch A Part-XII(Site Clearance) Lump sum price worked out by the contractor for (Site Clearance)as listed in Schedule A Part-XII against the lump sum priceinserted by the MES. 16 Note for Srl No 2 to 15The percentage above / below the SSR -2020 (part-II) rates shall be derived from the amount quoted by the contractor against Srl No. 2 to 14by comparing it with the amount inserted / pre- priced by the department and the same shall be applicable for the items of respective schedule 17 Schedule A Part-XIII (Miscellaneous items of works) 18 INTERNALELECTRIFICATION 19 Item No 02 : Materialand labour for point wiring complete with 1.5 sqmm PVC insulated, FRLSH type, ISI marked,conforming to IS-694/1990 unsheathed,multistranded,single core, copperconductor cable 1100 volts grade colour code cablesdrawn through and including PVCConduit 20 mm dia medium grade(MMS/HMS) andincluding cutting, chasing work at any height and all accessoriesconcealedinwalls / roofs / floors / ceiling etc. 20 flush mountingMS box with top,bottom,side/back wall knockout for conduitentry from any direction made out of 1.60mm thick suitable for fixing of andincludingwhite/Silver/Dark bronzecolour modular blankingplate as per number of switch modules flush mountedfor fixing of modular switches,sockets,fan regulators, blank plate etc and including above mentioned colourmodular plate cover of required modules andincluding 1.5 Sqmm PVC insulated multistranded FRLSH type unsheathed(Green colour),single core cable with copper conductor cable as earth continuity conductor andconnecting to common earth dolly and including making good the disturbed surfaces to match with existing surface and colour shade with putty for smooth finishing complete all as specified and directedfor the following:- 21 (a) One light point controlled by one switch. 22 (b) Onefan point controlled by one switch and oneregulator. 23 (c) Oneexhaust fan point controlled by one switch . 24 (d) One 5 pin 6 amps socket point controlled by one 6 amps switch on independent board . 25 (e) One 5 pin 6 amps socket point controlled by one 6 amps switch on same board . 26 (f) One bell/buzzer point controlled by one bell push. 27 (g) One light point controlled by two 2 way switches. 28 Item No 02 : All as per item No.1(d) & (e) above,but point wiring with 2.5 sqmm and earth conductor of size 2.5 sqmm complete all as specified and directed for the following:- 29 (a) One 6 pin 16/6 amps socket outlet point controlled by one 16 amps switchon independent board. 30 (b) One 6 pin 16/6 amps socket outlet point controlled by one 16 amps switch on same board. 31 Item No 03 :All as per item No.1 (d) above ,but point wiring with 4.0 sqmm and earth conductor of size 4 sqmm complete all as specified and directed. 32 Item No 04 : Supply & fixingand sheet metal enclosurewith acrylic door type, double door ,415 volts AC,VTPNDB, 4 way,8+12 modules, flush mounting with 200amps copper busbar, 2 neutral/earth bars links and MCCB incomer,and MCB SPN/SP/TPNas outgoing and complete forIP43&54 DBs protection complete all as specified and as directed. Note for item No.22 to 32- MCCB/MCB DBs and MCBs/MCCBs both are used same make only 33 Item No 05: Material and labour for Earthing complete with galvanised steel earth plate electrode 600mmX 600mmX 6mm thick buried directely in ground vertically ( earth pit not less than 2.25 meters deep below ground level) with top edge of plate not less than 1.5 metres belowground level, connected to and including galvanised iron wire 4 mm dia and light grade protection pipeof 15 mm diafrom earth electrode up to test point or up to 7.5mtr whichever is less by means of GIbolts, nuts, check nuts and washersall as per electrical plate No 3 of SSR Pt-I and GI watering pipe of 20 mm dia medium grade,GI funnel with wire mesh,including charcoal, salt packed all around the earth electrode plate in layers, PCC earth pit chamber 1:3:6 type C1, of size 45X 45X 45 CM,RCC cover 1:2:4 type B1 of size 45X45X6CM, excavation/earth work in any strata and returning filling, removal of surplus soil and testing/test point for required valueincluding removing old item completeall as specified and directed. 34 External Electric supply 35 Item No 06 :Supply, installation, testing and commissioning of step down copper wound transformer of capacity 315 KVA (Energy Efficient LEVEL 3 ), outdoor type, plinth platform of min size 2.4 x 2.4 x 1.5 Mtr (Solid PCC Block) complete with standard fittingts and accesswories, HT 11 KV 3 phase, Lt 433 volts, 3 phase 4 wire with off load tappings on HT side to vary secondary voltage within limit, all as per IS:1180 (Part-I)-2014 (latest edition) with amendment no. 1,2,3 & 4 (Level 3). oil cooling with fins vector group: DYN 11, incl initial oil fitting complete all as specified incl the following accessories:- 36 a) three numbers porcelain bushing HT, 11KV with Brass bushing Rod, Nuts, bolts and washers etc inside cable end box b) One cable box LT side consisting of 4 numbers porcelain with brass bushing rods complete with nuts and washers suitable for runs of 3.5 core LT UG cables c) Oil conservator with filter type drain valve and oil level guage 37 d) Dehydrating breather with fast feel of dehydrating agent e) Explosion Vents f) thermometer pocket on tank cover g) Rating Plate on terminal marking plate h) Earthing arrangement i) Oiil drain filter valve j) Oil Drain Valvek) Lifting Hook 38 l) Oil conservator with filling hole and capm) Air release valve plugn) Four plate solid cast steel detachable rollerso) Buchholz relay p) Earth Bushing for neutral Outside the cable box for neutralq) Suitable size of channel on foundation for fixing the transformer with jint and stopper(r) Plateform for mounting of transformer made up of PCC 1:2:4, 20 mm graded stoen aggregate, solid block and making all faces fare using extra cement as per manufacturer design of required length, width and hight in and including providing of 02 nos ISMC 100 chanel embe3dded in PCC of wuitable length as directed at site by the engr in charge in and including earth work complete. 39 Note: (i) Anything missed out above but technically required for proper operation of transformer is deemed to be included in the quoted rate. 40 Item No 07 : Supply, laying & testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty)with stranded aluminium conductor, 11000 volts grade, of size 3 core 95 sq mm complete all as specified and as directed. 41 Item No 08 : Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 95 sqmm 3½ core complete all as specified and as directed. 42 Item No 09 : Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 240 sqmm 3½ core complete all as specified and as directed. 43 Item No 10 : Supply and fix cable jointing kit for 1.1 KV grade cable for straight through/ end terminal joint complete with Jointing material heat Shrink type and accessories suitable for 3 ½ / 4 core XLPE, armoured, Al conductor cable of size 95 sqmm,Indoor/Outdoor type complete all as specified and as directed. 44 Item No 11 : Supply ,fabrication, installation and testing of LT out door type factory made CPRI Approved ,feeder piller box of made out of 3.15 mm thick CRCA sheet dully supported with mild steel angle iron of size 40X40X5mm vertical legs frame with front and back side openable ,single hinged door / shutter with locking arrengement and powder coated finish both internal and external steel surfaces after necessary preparation of steel surfaces including providing PCC (1:3:6) type C2 foundation of suitable size and connections of all outgoing / incomming existing cable of any size drawing / digging out cable from loops in trenches inclusive of necessary excavation and earthwork as required and relaying the cables including the following fitment accessories all complete as specified and as directed. 45 Incoming (a)MCCB, adjustable thermal magnetic release type, 4 poles, 415 Volts, Ics = 100% Icu, 35 KA breaking capacity, rating 400 Amps including all fixing accessories with both ends spreader links-01 No. (b)Digital voltmeter of range (0-500) volts, flush mounting type of size 96mm x 96mm (4”x4”) square dial with selector switch – 01 No.(c)Digital Ammeter of range (0-250) Amps, flush mounting type of size 96mm x 96mm (4”x4”) square dial with selector switch – 01 No.(d)LED Neon indicator lamp (RYB) with holder and fuse holder 230/250 volts,AC -01 set (set of three). 46 Outgoing(a)MCCB, adjustable thermal magnetic release type, 4 poles, 415 Volts, Ics = 100% Icu, 36 KA breaking capacity, rating 250 Amps including all fixing accessories with both ends spreader links-01 No. 47 (b)MCB,4 pole, 415V, C series rating 200Amp Amps including all fixing accessories with both ends spreader links-02 No. (01 + 01 spare) 48 (c ) Copper strip busbar of 600 Amps current carrying capacity with PVC sleeves with maintained the colour code and provision of making holes with Copper nuts, bolts & washers for cable connections including hydrograpic insulators with nuts & bolts at both ends= 04 nos. 49 (d)Enamelled iron danger notice plate of 1.60 mm thick mild steel sheet of size 200 mm X 150mm , white with letters , figures and conventional skull and bones in signal red and fixed with nuts and bolts on door / shutter of JB for LT -01 No. 50 Item No 12 :M&L for Shifting of existing VCB from existing location near pump house No:2 over head tank to proposed building approx 300 Mtr with the help of crane including necessary T&P including Servicing, comprising of overhauling and refixing the same after repairs: (a) Tripping off the breaker, lowering the breaker with raising/lowering handle and pulling out the breaker complete from the panel along with the trolley for servicing/inspection.(b) Servicing/Inspecting/checking of automatic safety shutter operation for serviceability and replacement of spares if required. 51 (c) Servicing/Inspecting/checking ofcircuit spoutand cicuit spout connections for RYB phases and replacement of spares if required.(d) Dismantling and checking of cross bar assembly, fixed contacts and current carrying parts of the breaker, trolley, insulated assembly and checking lamination with clamps, epoxy spout, isolator assembly etc. (e) Setting, reassembling, cleaning, adjustment of fixed contacts, main contact, arcing contacts and chamber baffle pot assembly, moving contact for proper setting of auxiliary contacts operating mechanism. (f)Servicing/Inspecting/checking ofsecondary sockets/busbar earthing plugs/earthing sockets and replacement of spares if required. 52 (g)Checking, setting and adjustment of lowering and raising operation of the breaker trolley. (h)Lubrication and greasing of all moving parts of the trolley, stopper bolt for proper operating and closing of shutter gear, isolation resistance of trolley of with vacuum interrupter assembly. (j) The inspection of HT switch gear shall involve:-(i) Inspection of truck & hoist assembly.(ii) Inspection of tank assembly & barriers.(iii) Inspection of assembly & components of solenoid assembly.(iv) Inspection of assembly & components of dependent mechanism.(v)Inspection of assembly & components of spring box mechanism.(vi)Inspection of motor mechanism spring charge assembly (vii)Inspection of assembly of trip unit & related components.Notes: (i) The rate quoted shall be deemed to include for necessary T&P, nuts, bolts, washers, gasket, insulation tape, compound and any damaged parts etc. to put in to the VCBs and panels in serviceable condition, testing and commissioning all as specified and as directed by the Engineer-in-Charge. 53 Item No 13 : M&L Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure. 54 Item No 14 : M&L Costruction of a 18 sqm room with a height of 3.5 mtrs, designed to house a vaccum circuit breaker (VCB). The costruction will include foundation work, walls, roofing , flooring, plastering and miscellaneous items like windows and doors. complete all as specified and as directed. 55 External Water Supply 56 Item No 15 : M & L for Construction of brick masonry valves pits , of the following internal dimension complete with 3015mm thick MS sheet cover angle iron frame duly painted with locking arrangement including all necessary excavation and earth work PCC wok complete. 57 (a) 900mm x 900mm x 900mm 58 (b) 600mm x 600mm x 600mm 59 Item No 16 : Refixing MS/ GI/ CI DI pipe any type and connections in new or old position including cleaning internally and externally, any grade / make (in trenches) including all type of new fittings i.e. sockets, Tee, union, elbow etc complete all as specified and as directed. 60 (a)100 mm dia 61 (b) 150 mm dia 62 Item No 17 : Supply and fixing in replacement ductile iron pressure pipes, class K7, centrifugally cast with spigot and socket ends as per following conforming to IS 8329/2000 with cement mortar lining inside the pipes with outside zinc coating suitable for push-on joint (rubber gasket D jointing) in any length including DI specials as required at site confirming to IS 8329/2000 and all jointing materials and making good for distrubed surfaces of roads, pathways etc while laying the pipe line at site, site clearance for the route of pipe line, welding, excavation of pipe line, connections etc complete all as specified and as directed. (a) 150 mm dia 63 Refrigeration System 64 Item No 18 : Supply and fix refrigerator, electric driven (single phase), capacity upto to 195 Litres .BEE 5 star rated complete all as specified and directed. 65 Item No 19 :Supply and installation of voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 2 KVA. 66 Water cooler 67 Item No 20 : Supply, installation and Commissioning water cooler, Electric driven,(single phase 230 volts) having approx storage capacity of 120 Litres and nominal cooling capacity of 60 Litres per hour complete all as specified. 68 Item No 21 : Supply and installation of voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 Volts to 250 Volts with output voltage stabilized at 230 Volts with accuracy of ± 2.5% and of capacity 2 KVA complete all as specified. 69 Air Conditioning 70 Item No 22 : Supply and installation of voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 Volts to 250 Volts with output voltage stabilized at 230 Volts with accuracy of ± 2.5% and of capacity 5 KVA complete all as specified. 71 Hot Water Supply 72 Item No 23 : Supply and fix Water heater storage type, electric,capacity 50 litres.BEE 5 star rated 73 Item No 24 : Supply and fix electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece complete all as specified and directed. 74 Dessert Cooler 75 Item No 25 : Supply and fix desert cooler electric driven (single phase), having nominal air flow capacity of 4000 CuM per hour (or nearest size).Steel body type complete all as specified and directed. 76 Electric Chimney 77 Item No 26 : Supply, installation testing and commissioning commercial kitchen chimney stainless steel body with filter size 96 X 30 including 1 HP exhust fan, Air outlet duck of chimney G.P sheet 0.50 mm thick of size 22 X 22 X 15 ft long complete all as specified and directed. 78 FIRE FIGHTING SYSTEM(DOWN COMMER) & FIRE ALARM SYSTEM 79 Item No 27 : Supply only of fire extinguiser ISI marked CO2 type Fire Extinguisher 4.5 KG capacity conforming to IS : 15683 :2006 (old IS : 2878) made from seamless cylinder conforming to IS : 7285 duly approved by chief controller of explosive , Nagpur fitted with ISI Marked Controlled valve conforming to IS : 3224 , high pressure 1 mtr long discharge hose and horn complete with initial gas charged with carrying handle and wall mounting bracket, , suitable for operating between 30 degree centrigrade to + 55 degree centigrate, Fire Rating Class - 138. 80 Item No 28 : Supply only of stored pressure fire extinguiser ISI marked powder type Fire Extinguisher 4 KG capacity suitable for Class A, B, C Fire consisting with discharge hose and nozzle of welded cylinder, squeeze lever discharge valve fitted with pressure indicating guage, internal discharge tube, discharge nozzle suspension bracket conforming to IS : 15683 :2006 (old IS : 2878) duly charged with ISI Marked Mono Ammoniumphosphate base ABC powder conforming to IS : 14609 and pressurized with Nitrogen Gas, suitable for operating between 30 degree centrigrade to + 55 degree centigrate, Fire Rating Class - 1A & 13B 81 Item No 29 : Supply only of Fire bucket iron body red colour 10 L capacity for dry sand stored type ISI MarkedIS : 2546 :2006, complete all as specified and as directed. 82 Item No 30 : Supply only of Fire Extinguisher Mechanical Foam type ISI Marked Foam (AFFF) type Fire Extinguisher 9 ltrs capacity fitted with Forged Brass squeeze lever discharge valve, conforming to IS : 15683 :2006, complete with initial refill consisting of ISI Marked CO gas cartridge of 60 gms capacity conforming to IS 4947 and ISI Marked AFFF conforming to IS : 4989, suitable for operating between + 50 degree centrigrade , Fire Rating Class - 3A & 34B 83 Sewage Disposal 84 Item No 31 : M&L for DWCPE (SN8) pipes 180 OD/163 ID, laid and jointed complete complete all as specified and directed for the following internal dia of pipes. 85 Item No 32 : Construction of Conventional RCC Septic tank designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, RCC M-30 Design mix in walls, Base slab, Baffle walls and roof slab including beams etc with Vent shaft, manhole openings with cover connection etc., complete with effective depth of 1.5 meter and overall depth of 3 meter for 100 users conventional type. 86 Item No 33 : Construction of Soakage wells excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M-25 concrete including intercepting chamber and screen chamber made of Brick masonry in CM, RCC cover slab in M25/SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size 3.6 M dia X 3.0 M effective depth. 87 SCHEDULE A(Schedule of credit)Schedule of Credite Rs 50001.00 (Minus) inserted by the MES.(Note : Credit amount shall be deducted manually to arrive net bid amount)
Contract Date: Jun 27, 2026 Contract Value : 10.28 Crore
Statutory Bodies & Commissions/Committees No of Bidders 10
5.
Power #10775882 Price Bid
Rate Contract for procurement/Installation charges of various materials required for maintenance of 33/11 KV Receiving stations for upkeeping of power supply of Receiving stations under jurisdiction of STD Pulwama for the year 2025-26 or till next Rate Contract.- 1 Dismantalling of 2 11KV VCB Panel complete 3 33KV C&R Panel complete 4 33KV VCB / MOCB complete 5 Installation,testing and commissioningof Switchgear System complete(material to be provided by the department) 6 11KV VCB Panel complete 7 33KV C&R Panel complete 8 33KV VCBcomplete 9 Supply of 11 kV VCB Panel Board 12 kV, 1250A, 25 KA,(Incommer) as per Technical Specifications of REC Std 10 Supply of 11 kV VCB Panel Board 12 kV, 1250A, 25 KA,(Outgoing) as per Technical Specifications of REC Std 11 Supply of 33 kV VCB(36 kV, 1250A, 26.2 kA, Outdoor Type) as per Technical Specifications of REC Std 12 Supply of 33 kV C&R Panel with nemurical Relays with Differential Relay ( IEC 61850), Voltmeter, Ammeter, Annunciation Windows with annunciation relays, 3-phase Tri-vector meter -5 Amps, DLMS Compliant as per Technical Specifications of REC Std 13 Supply of 33 kV C&R Panel with nemurical Relays with out Differential Relay ( IEC 61850), Voltmeter, Ammeter, Annunciation Windows with annunciation relays, 3-phase Tri-vector meter -5 Amps, DLMS Compliant as per Technical Specifications of REC Std 14 Supply of fresh 11KV C.T by way of Replacement of Damaged/Burnt Out/low size 11 KV C.T of same ratio,type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for following 11KV VCB with ratio 800-400/5-5-5A, 600-300, 400-200, 100-50 15 Alsthommake 16 Easun Reyroll Make 17 Vijay Make 18 Sudhir Make 19 Electric Field 20 Crompton Greeves 21 Allind 22 ABB Make 23 Pascal Make 24 Hartek Make 25 Supply of 33KV Hand Gloves of Crystal or equivalent make conforming to IS: 4770, 13774 26 Installation,testing and commissioning of fresh 11KV C.T by way of Replacement of Damaged/Burnt Out 11 KV C.T of same ratio,type,make and class already installed in panel (material to be provided by the department) (for 11KV VCB panels) 27 Supply of 11KV P.T by way of Replacement of Damaged/Burnt Out 11 KV P.T of same ratio,type,make and class already installed in panel confirming to IEC 60044-1-2000 standards (for 11KV VCB panels) 28 Installation,testing and commissioning of fresh 11KV P.T by way of Replacement of Damaged/Burnt Out 11 KV P.T of same ratio,type,make and class already installed in panel (material to be provided by the department) (for 11KV VCB panel) 29 Providing offresh male contact (set of 06 Pcs) of following 11KV VCB by way of Replacement of Damaged/Burnt Outmale contact setof same composition,type,make and class already installed in 11KV VCB panel 30 Alsthommake 31 Easun Reyroll Make 32 Vijay Make 33 Sudhir Make 34 Electric Field 35 Crompton Greeves 36 Allind 37 ABB Make 38 Providing offresh male contact (set of 06 Pcs) of following 11KV VCB by way of Replacement of Damaged/Burnt Outmale contact setof same composition,type,make and class already installed in 11KV VCB panel 39 Alsthommake 40 Easun Reyroll Make 41 Vijay Make 42 Sudhir Make 43 Electric Field 44 Crompton Greeves 45 Allind 46 ABB Make 47 Providing of 11KV Vacuum Interruptor by way of Replacement of Damaged/Burnt Out 11KV Vacuum Interruptor of same composition,type,make as already installed in 11KV VCB panel (1250amps) of following make 48 Alsthommake 49 Easun Reyroll Make 50 Vijay Make 51 Sudhir Make 52 Electric Field 53 Crompton Greeves 54 Allind 55 ABB Make 56 Pascal Make 57 Hartek Make 58 Fixing of fresh 11KV Vacuum Interruptor by way of Replacement of Damaged/Burnt Out 11KV Vacuum Interruptor of same composition,type,make already installed in 11kv vcb panel (material to be provided by the department) 59 Supply of Numerical/Digital Relayby way of Replacement of Damaged/Burnt of same ratio(A.C &D.C),type,make and class already installed in panel.All relays shall conform to the requirements of IS:3231/IEC-60255 and IEC-61850 of (MIT113 ER / Ashida 141A) Operating Voltage 30-36Volts 60 Fixing , testing and commissioning of Numerical/Digital Relay (MIT113 / Ashida 141A) by way of Replacement of Damaged/Burnt of same ratio(A.C &D.C),type,make and class already installed in 11KV VCB panel.(material to be provieded by the department) 61 Supply of Panel Insulator (Supporting Insulator for Bus) for 11KV VCB panels like Easun Reyroll, Allind, Alsthom, Crompton Greeves, Electric field or the like 62 Rectification,Re-Alignment,setting right the electricalsection of 11KV Breakers(11KV VCB panel) 63 Rectification,Re-Alignment,setting right the mechnicalsection of 11KV Breakers(11KV VCB Panel) 64 Rectification,Re-Alignment,setting right the electrical section of 33KV C&R panel 65 Rectification,re-alignment,setting right the mechnical section of 33KV VCB 66 Rectification,re-alignment,setting right the mechnical section of 33KV MOCB 67 Replacement of damaged clamps (A.A) confirming to IS:617 standards (for 33KV VCB,33KV L.A,33KV Isolator) with fresh one complete. 68 Supply of Tripping/closing coils suitable for 11KV VCB Panels like Allind,Vijay,Crompton greeves,Easun Reyroll,Alasthom, Electricfield,Sudhir,ABB,L&T etc 69 Providing of clamps (Bi-Metallic) confirming to IS: 1285 standards ( for 33KV P.T Clamps,C.T clamps,Transformer Clamps(Both H.V & L.V Side),Pad Clamps) 70 Providing of 33KV Post Insulatorsby way of replacement of damaged one confirming to IEC 61109/92-93 with latest amendments (porceline type) 71 Supply of 33KV Polymeric Composite Pin Insulator 36KV,10KN,Lighting Impulse 170KV Positive & 180 KV Negative,Creepage distance 900mm sauitable for 0.15/0.2ACSR 72 Providing of 33K VCB Bushes complete assembly by way of replacement of damaged one confirming to IS:2099 standard (porceline type) 73 Providing of 33KV HV Bushes of power transformers complete assembly by way of replacement of damagedoneconfirming to IS:2099 standards (porceline type) 74 Providingof 11KV LV Bushes of transformers complete assembly by way of replacement of damaged one confirming to IS: 2099 standards (porceline type) 75 Supply of 33KV C.T(3-core)confirming to IEC:185 and IS:2705 (part-1 to 4) standardsof ratio 300-150/5-5-5A/ 250-125/5-5-5A)outdoor type 76 Fixing,installation,testing and commissioning of fresh 33KV CT (3-core) of different ratio confirming to IEC:185 and IS:2705 (part-1 to 4) standards by way of replacement of damaged one (material to be provided by the department) outdoor type 77 Supply of33KV P.Tof (110V/√3) confirming to IS:3156 (part-I to Part-III) outdoor type 78 Fixing,installation,testing and commissioning of fresh 33KV PT (110V/√3)confirming to IEC:185 and IS:2705 (part-1 to 4) standards by way of replacement of damaged one (material to be supplied by the department) outdoor type 79 Providing of 33KV isolator 800 Amps heavy duty confirming to IS:9921 / IEC-62271-102 standards 80 With earthing blade 81 Without earthing blade 82 Fixing,installation,testing and commissioning of fresh 33KV isolators 1250 Amps heavy duty confirming to IS:9921 / IEC-62271-102 standards (material to be supplied by the department) (with earthing blade / without earthing blade) 83 Providing of 33KV link set (610x50x6mm male copper balde and female part 200X50x3mm ) by way of replacement of damagedoneheavy duty 600amps. 84 Installation,Testing and commissioning of 33KV link set (610x50x6mm male copper balde and female part 200X50x3mm ) by way of replacement of damagedoneheavy duty 600amps. (material to be supplied by the department) 85 Providing of 11KV G.OSet 200 Amps (with earthing blade) heavy duty conforming to latest version of IS - 9921 (part-I to V) with earthing blade by way of replacement of damaged one 86 Installation,Testing and commissioning of 11KV G.OSet 200 Amps heavy duty conforming to latest version of IS - 9921 (part-I to V)(material to be supplied by the department) 87 Providing, fixing, installation, testing and commissioning of 11KV Isolators,800/630amps. conforming to IS 9921/IEC-129 standards 88 With earthing blade 89 Without earthing blade 90 Installation,Testing and commissioning of 11KV Isolators,800amps. conforming to IS 9921/IEC-129 standards (with earthing blade/without earthing blade )(material to be supplied by the department) 91 Providing, of 11KV link set (400x50x6mm male copper balde and female part 100X50x3mm ) by way of replacement of damagedoneheavy duty 600amps. 92 Installation,Testing and commissioning of 11KV link set (400x50x6mm male copper balde and female part 100X50x3mm ) by way of replacement of damagedoneheavy duty 600amps. (material to be supplied by the department) 93 Providing of 33KV Drop out setwith porcelaine insulatorby way of replacement of damaged one as per latest IS standard with latest amendments therof. 94 Installation,Testing and commissioning of 33KV D.O. set by way of replacement of damaged one as per latest IS standard with latest amendments therof.(material to be supplied by the department) 95 Providing of 33KV L.A. set (porcelaine type with clamps) by way of replacement of damaged one as per latest IS standard with latest amendments therof. 96 Installation,Testing and commissioning of 33KV L.A. set by way of replacement of damaged one as per latest IS standard with latest amendments therof. (material to be supplied by the department) 97 Oil Toping in 33/11 KV Power Transfromersand 33KV MOCBs /CT/PT (Transformer oil to be supplied by the department) 98 Providing of Winding Temperature meter by way of replacement of damaged one suitable for 33/11 KV, 10MVA/6.3MVA/5.0MVA Power Transformers 99 Providing of Oil Temperature meter by way of replacement of damaged one suitable for 33/11 KV , 10MVA/6.3MVA/5.0MVA Power Transformers 100 Providing ofinterrupting chambers (Housing Assembly)suitable for 11KVVCBof different make by way of replacement of damaged one 101 Crompton Greeves 102 S&S 103 Vijai 104 BHEL 105 Alasthom 106 Easun Rey roll 107 Electric Field 108 Installation ofinterrupting chambers (Housing Assembly)suitable for 11KVVCBof different make by way of replacement of damaged one 109 Providing of Arcing interrupting chamberssuitable for33 KVVCB panels of different make by way of replacement of damaged one 110 fixing of Arcing interrupting chamberssuitable for33 KVVCB panels of different make by way of replacement of damaged one 111 Supply of breather of stnadard quality for Power Transformers of different make 112 Providing ofspouts bushing suitable for 11KVVCB (Alasthom/Easun Reyroll/Vijay/Sudhir/Electric field/Crompton greeves/ ABB-Make equiv...) panel of different make by way of replacement of damaged one 113 Providing of Bush Rods suitable for 33/11KVPower Transformer (10MVA/6.3MA/5.0MVA) by way of replacement of damaged one 114 33KV side 115 11KV side 116 36V , 200AH Battery Bank (Comprising of 3 No batteries of 12 V each)conforming to IEC60896-21/22,Lead acid Type of Exide Make 117 Supply of automatic 36V,DC,15amp. (constant current constant voltage ) fully automatic battery charger float cum boost type 2KVA 118 Supply of 11KV (E) grade armoured ,3-core,Xlpe Power Cable (with stranded compact circular aluminium with extruded semi conducting compound,Xlpe insulated and overall PVC sheathed cable confirming to IS:7089 (Part-II)-1985 with the latest amendments by way of replacing the damaged cable of 11KV switchgear (havells or Glastor or finolex make) 119 630mm^²,3-core 120 400mm^²,3-core 121 300mm^²,3-core 122 240mm^²,3-core 123 185mm^²,3-core 124 150mm^²,3-core 125 Laying,Testing,commissioning of 11KV (E) grade armoured ,3-core,Xlpe Power Cable (with stranded compact circular aluminium with extruded semi conducting compound,Xlpe insulated and overall PVC sheathed cable confirming to IS:7089 (Part-II)-1985 with the latest amendments by way of replacing the damaged cable of 11KV switchgear(material to be supplied by the department) 126 630mm^²,3-core 127 400mm^²,3-core 128 300mm^²,3-core 129 240mm^²,3-core 130 185mm^²,3-core 131 150mm^²,3-core 132 120mm^²,3-core 133 Supply of 11KV (E) grade armoured ,1-core,Xlpe Power Cable (with stranded compact circular aluminium with extruded semi conducting compound,Xlpe insulated and overall PVC sheathed cable confirming to IS:7089 (Part-II)-1985 with the latest amendments by way of replacing the damaged cable of 11KV switchgear (havells or Glastor or finolex make) 134 630mm^²,1-core 135 400mm^²,1-core 136 300mm^²,1-core 137 240sqmm, 1-core 138 185mm^²,1-core 139 150mm^²,1-core 140 120mm^²,1-core 141 Laying,Testing,commissioning of 11KV (E) grade armoured ,1-core,Xlpe Power Cable (with stranded compact circular aluminium with extruded semi conducting compound,Xlpe insulated and overall PVC sheathed cable confirming to IS:7089 (Part-II)-1985 with the latest amendments by way of replacing the damaged cable of 11KV switchgear(material to be supplied by the department) 142 630mm^²,1-core 143 400mm^²,1-core 144 300mm^²,1-core 145 240mm^²,1-core 146 185mm^²,1-core 147 150mm^²,1-core 148 120mm^²,1-core 149 Supply of 2.5 sqmm Control cable armored , copper conductor sheathedPVC insulated multi colour voltage grade 1.1 KV conforming to IS:1554(Part 1),IS 8130,IS ;5831 (Havells or Gloster or finolex make ) 150 2 core 151 4 core 152 6 core 153 8 core 154 12 core 155 Supply of 11KV ,3 core heat shrinkablestraight through jointing cable kit(outdoor Type) suitable for already installed 11KV Xlpe Power Cable confirming to IS:13573/1993with latest ammendments if any (3M or RAYCHEM make) 156 630mm^²,3-core 157 400mm^²,3-core 158 300mm^²,3-core 159 240mm^²,3-core 160 185mm^²,3-core 161 150mm^²,3-core 162 120mm^²,3-core 163 Supply of 11KV cable 3 core terminationkits (Indoor/ outdoor Type)3M or Raychem 164 630mm^²,3-core 165 400mm^²,3-core 166 300mm^²,3-core 167 240mm^²,3-core 168 185mm^²,3-core 169 150mm^²,3-core 170 120mm^²,3-core 171 Installation,Testing and commissioning of 11KV cable Jointing/ terminationkits (indoor Type)(material to be provided by the department) 172 630mm^²,3-core 173 400mm^²,3-core 174 300mm^²,3-core 175 240mm^²,3-core 176 185mm^²,3-core 177 150mm^²,3-core 178 120mm^²,3-core 179 Supply of 11KV ,1 core heat shrinkablestraight through jointing cable kit(outdoor Type) suitable for already installed 11KV Xlpe Power Cable confirming to IS:13573/1993with latest ammendments if any (3M or RAYCHEM make) 180 630mm^²,1-core 181 400mm^²,1-core 182 300mm^²,1-core 183 240mm^²,1-core 184 185mm^²,1-core 185 150mm^²,1-core 186 120mm^²,1-core 187 Supply, of 11KV cable 1 core terminationkits (Indoor/ outdoor Type)3M or Raychem 188 630mm^²,1-core 189 400mm^²,1-core 190 300mm^²,1-core 191 240mm^²,1-core 192 185mm^²,1-core 193 150mm^²,1-core 194 120mm^²,1-core 195 Installation,Testing and commissioning of 11KV cable jointing/ terminationkits (indoor Type)(material to be provided by the department) 196 630mm^²,1-core 197 400mm^²,1-core 198 300mm^²,1-core 199 240mm^²,1-core 200 185mm^²,1-core 201 150mm^²,1-core 202 120mm^²,1-core 203 Dragging(upto Avg. lead 50 mtrs.)and rotation (if required) of 33/11KV Power Transformer (Complete Job) 204 10 MVA 205 6.3 MVA 206 5.0/4.0/3.15 MVA 207 Loading of Power Transformer to the sub station bed / plateform (Complete Job) 208 10 MVA 209 6.3 MVA 210 5.0/4.0/3.15 MVA 211 Unloading of Power Transformer fromthe sub station bed / plateform (Complete Job) 212 10 MVA 213 6.3 MVA 214 5.0/4.0/3.15 MVA 215 Carriage of Power Transformer upto 20KM fromsource to destinantion 216 10 MVA 217 6.3 MVA 218 5.0/4.0/3.15 MVA 219 Carriageof Power Transformer (10/6.3/5/4/3.15 MVA) beyond 20KM 220 Unloading of material which are to be handled with care like 33KV CT / 33KV PT etcincluding manual carriage from dumping site upto proper stacking 221 Loading of of material which are to be handled with care like 33KV CT / 33KV PTetc including manual carriagestacking site upto loading 222 Manual Carriage of materials like 33KV CT / 33KV PT 33KV C&R panel , 33KV VCB panel , 11KV VCB panel etc 223 Upto first 100mtr lead 224 For every additional 50mtr or part there off 225 Unloading of bulky material which are to be handled with care like 33KV C&R panel , 33KV VCB panel , 11KV VCB panel etc including manual carriage from dumping site upto proper stacking 226 Supply ofGears for 11KV VCB of different make(Big) 227 Supply ofGears for 11KV VCB of different make(Small) 228 Supply ofDC Delco Motor for 33 KV VCB 229 Supply ofDC Delco Motor for 11 KV VCB 230 Supply of Breaker Mechanism of reputed make 231 Loading of bulky material which are to be handled with care like 33KV C&R panel , 33KV VCB panel , 11KV VCB panel etc including manual carriagestacking site upto loading 232 Supply ,installation,testing and commissioning of copper Bus Bar (50x8mm) tin coated with duly heat shrinked insulated 233 Repairing /Replacement of 11KV VCBs 234 Tripping Mechanism 235 Modification of Mechanism 236 Re-setting links 237 Replacement of operating shaft 238 Shower contact 239 Isolating Sockets 240 Closing mechanism (replacement) 241 High Tension spring 242 Tripping shaft 243 Rollers 244 Latch assembly 245 Overhauling of 11KV VCB 246 Deco spray painitng 247 Installation,Testing and commissioning of Power Transformer of capcity (3.15/4 MVA/5MVA/6.3 MVA/10MVA) complete job including all neceesary testing at site 248 Dismanteling of Power Transformer of capcity (3.15MVA /4 MVA /5MVA /6.3MVA /10MVA) complete job 249 Supply of 33KV, Single coreAluminium, round wire Armoured XLPE Cable , FRLS One spare cable 250 185sqmm 251 240sqmm 252 300sqmm 253 400sqmm 254 630sqmm 255 Laying,testing and commissioningof 33KV, Single coreAluminium, round wire armoured XLPE Cable , FRLS One spare cable 256 185sqmm 257 240sqmm 258 300sqmm 259 400sqmm 260 630sqmm 261 Providing of Cable Termination Kits (indoor/outdoor) for 33KV Grade single core cable of size 262 185sqmm 263 240sqmm 264 300sqmm 265 400sqmm 266 630sqmm 267 Laying,testing & commissioning of Cable Termination Kits (indoor/outdoor) for 33KV Grade single core cable of size 268 185sqmm 269 240sqmm 270 300sqmm 271 400sqmm 272 630sqmm 273 Supply of Buchhloz relay for 33/ 11 KV transformer protection(10MVA / 6.3 MVA) as per IS 3637:1966 274 Supply of G.I Bolt full threadof sorts of dia 3/4’’ and 1/2 “ with washers and nuts of different sorts and sizes 275 Supply of G I Wire (8 SWG) as per IS standard with latest amendments 276 Supply of Guy wire(7/14) SWG as per IS standard with latest amendments 277 Supply of Digital Protection Relay non-communicableModel Type -141A(Ashida -Make), 3 O/C + 1 E/F , auxilairy voltage 0-30Vconfirming to ISO 9001:2008 standards. 278 Supply of progammable numerical relay with communication protocol IEC618503 O/C + 1 E/F with SCADA compatible relay VAMP57 (IEM) protection,relay type V57F3ABA1ACA, (Schneider make)having ports dual RJ45 with 10 digital inputs and 6 digital outputs, auxiliary voltage =30V minimum, frequency = 50hz, rated phase current In=5A, rated residual current Io=5A, Rated auxiliary voltage (Uaux)=30 DC 279 Supply of Push type ON-OFF switches suitable for 33/11kV Pannel boardmake BHEL,Crompton Greeves, Alsthom, ABB, New Electric Field, Sudhir or the like 280 Supply of Trip solenoids voltage operated coil (D.C 30-36V) complete encased suitable for11KV VCB Panels Allind / Vijay / Easun reyroll / Alasthom / Crompron Greeves / New Electric Field / Schneider / BHEL/Pascal/ABB make 281 Supply of 11kV Lightnening Arrestor station Type (Poreclaineinsulators) 282 Supply of HT Tape Roll as per IS standard with latest amendments 283 Supply of indication lamps suitable for 33/11kV Pannel board make BHEL,Crompton Greeves, Alsthom, ABB, New Electric Field, Sudhir etc 284 Supply of Monoplast Tape as per IS standard with latest amendments 285 Supply of LT insulation tape as per IS standard with latest amendments 286 Supply of master trip relay 24-50 V suitable for 11KV VCB Switch gear panels of Allind / Vijay / Easun reyroll / Alasthom / Crompron Greeves / New Electric Field / Schneider / BHEL/Pascal/ABB and like make 287 Supply of Auxiliary switch suitable for 11KV VCB panels like Beeco lawrie, Easun reyroll,Allind,Vijay,Alsthom,Crompron greeves Electricfield /Pascal/ABB 288 Supply of selector switch suitable for 11KV VCB Panels like Beeco lawrie, Easun reyroll,Allind,Vijay,Alsthom,Crompron greeves Electricfield /Pascal/ABB 289 Supply of aluminium thimbles of different sizes (185sqmm/240sqmm/300sqmm/400sqmm) of 3D or Dowells make 290 Supply of ampere meter (digital type) suitable for 11KV VCB panels 291 Supply ofVoltmeter(digital type) suitable for 11KV VCB panels 292 Supply of old sarees 293 Supply of welding electrodes as per IS standard with latest amendments 294 Supply of Petrolium jelly as per IS standard 295 Earthing Complete by G I Pipe 40mm or G I Rod 20mm 2.5 Mtr long through G I Strip as per REC Standard 296 Galvanised Stay set with 50X8mm Stay Clamps,Guy Insulator,Anchor Plat(300X300X8)mm,Nuts/Bolts ,Turn Buckle,1.8 Mt long 20mm Dia Sold GS Stay rod & 7/4.0mm Dia GI Std wire complete 297 Porceline 70 KN Disc Insulator 298 Porceline 45 KN Disc Insulator 299 Porceline 33KV Insulators (10 KN) 300 33KV G.I Pins with all accessories weighing 2700 gms 301 Fabricated Galvanised V -type Channel Iron X-arm,6-10 Long Ch Iron,Channel Iron Top,Angle Iron Belts, Clamps & Flat braces etc as per REC Standard for 33/11KV Lines. 302 33KV Polymeric Composite Pin Insulator 36KV,10KN,Lighting Impulse 170KV Positive & 180 KV Negative,Creepage distance 900mm sauitable for 0.1ACSR 303 33 KV Polymeric Composite Disc Insulator 36KV,Min failing load 70KN,Lighting Impulse 170KV Positive & 180 KV Negative,Creepage distance 900mm suitable for 0.05/0.1 ACSR Conductor 304 33 KV Polymeric Composite Disc Insulator 36KV,Min failing load 70KN,Lighting Impulse 170KV Positive & 180 KV Negative,Creepage distance 900mm suitable for 0.15/0.2 ACSR Conductor 305 P G Clamps for 200/150/100mm Sq ACSR 306 Supply of LED Yard lights 50 watts of philips/Havells 307 Supply of LT Aluminium cable of 10sqmm single core as per ISIS-7098 (Part-1) -1988 with latest amendments 308 Supply ofLED lamps 9 watt of philips/Havells make 309 Supply of LED Search light handled torch,3W (with built-in,rechargeable 4.5 Ah SMF battery),lighting range of upto 600meters 310 Filling of CO2 type Fire Extinguishers of 6.8Kg capacity 311 Supply of digital earth resistance tester having range from 0-2000 ohm (complete with operating manuals and drawings) 312 Supply of Safety Belt of class A & P harness including waist belt and a pole strap with a special type of freely moving buckle complete conforming toI.S.3521-1999 313 Supply of fire bucket with handle of 10 litre capacity duly painted as per standard 314 Supply of Safety Helmet conforming to ISO: 3873, IS 2925 : 1984 315 Supply of Electrical insulated CheckeredRubber Matting 25mm thick (1mtrX2mtr) conforming to IS 15652:2006, EC 61111 316 Supply of Meggar 5KVA battery operated (complete with operating manuals and drawings) 317 Supply of Pully Machine (complete with manuals) 318 5 Ton 319 10 Ton 320 Supply of Chain Pully Block (complete with manuals) 321 5 Ton 322 10 Ton 323 Supply of CO2 type Fire Extinguishers of 6.8Kg capacity fitted with trolley, delivery hose horn, wheel type release value etc (complete) 324 Supply of ABC Type Fire Extinguishers of 6.8Kg capacity fitted with pipes nozzles and all accessories 325 Supply of motor for spring charge suitable for 33/11kV switchgear make BHEL,Crompton Greeves, Alsthom, ABB, New Electric Field, Sudhir or the like 326 Supply of manually operated crimping tool of 3D or dowels make 327 Supply of aluminium ladder 40ft long, folded type (5-6mm thick) with rope and pully complete 328 Supply of 50sqmm welding cable of standard make(ISI marked) 329 Supply of heavy duty welding holder (500-1000A) as per IS standard with latest amendments 330 Supply of welding gloves as per IS standard with latest amendments (ISI marked) 331 Supply of heavy duty355-3.0X25(4mm) Cutting Blade (14’’)as per IS standard with latest amendments (Bosch make) 332 Supply of fibre type measuring tape (30m) of Topline or equivalent make(ISI marked) 333 Supply of heavy duty gas cutter as per IS standard with latest amendments of Kakkar or equivalent make. (ISI marked) 334 Supply of heavy duty gas gauge as per IS standard with latest amendments of Kakkar or equivalent make. (ISI marked) 335 Supply of 150mm,6’’ angle grinder of Hitachi or equivalent make(ISI marked) 336 Supply of 150mm,6’’ heavy duty cutting wheel blade of Bosch or equivalent make (ISI marked) 337 Supply of 3-phase Tri vector energy meter suitable for 11kV Panels / 33KV C&R panels make BHEL,Crompton Greeves, Alsthom, ABB, New Electric Field, Sudhir etc 338 Supply of Panel Bush for 11KV VCB panels like Easun Reyroll, Allind, Alsthom, Crompton Greeves, New Electric Field,ABB 339 Supply of Breaker Bush for 11KV VCB panels like Easun Reyroll, Allind, Alsthom, Crompton Greeves, New Electric Field,ABB 340 Supply of TNC/Local-Remote switch suitable for 11KV VCB panels like Easun Reyroll, Allind, Alsthom, Crompton Greeves,ABB, New Electric Field 341 Supply ofHeat Shrinkable cable Termination kits of 3M or Raychem make (outdoor Type) suitable for 33KV 3- core,Xlpe power cables 342 630sqmm 343 400sqmm 344 300sqmm 345 Laying,installation,testing ofHeat Shrinkable cable Termination kits of 3M or Raychem make (outdoor Type) suitable for 33KV 3- core,Xlpe power cables 346 Supply of standard quality Silica jel for various Capacity 33/11kV power transformers 347 Supply of tool kit as per IS standard with latest amendments 348 Providing and fixing of yard lights of 50watt along with 2.5sqmm 1 core PVC cable of 50mtrs and one MCB 6/16Amp. 349 Supply of Portable HEAVY DUTY ARC welding machines alongwith all accessories of standard Make 350 Supply of BDV Testing machines of standard Make 351 Supply of BDV woodcutter of standard Make 352 Supply of Conductor cutter of standard Make suitable for 0.2 ACSR Conductor 353 Supply of haevu duty Hydraulic crimping tool (40-400mm) of standard make 354 Providing of 3 Phase Turn ratio Meter of Reputed make 355 Providing of widing Resistance Meter of Reputed make 356 Proding of Gyser Element of reputed make as per requirement 357 Providing ond fixing of heavy duty fans along with Stand for forced cooling of Power Transformers 358 Proving of Limit Switch for VCBs of different Make 359 Proving of Antipumping Relays for VCBs of different Make 360 Proving of Announciator for VCB/ C & R Panel of different Make 361 4 Window 362 8 Window 363 Proving of Buzzer/Hooter (24-48V) for VCB/ C & R Panel of different Make 364 Proving of HRC fused 6A/10A for VCB/ C & R Panel of different Make 365 Proving of AVT fused 1A for 11KV/110V PT for replacement of damaged one 366 Supply and Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer’s specifications including appropriate priming coat, preparation of surface etc complete, on steel work including Channel iron, Angle iron, chainlink fencing and ST poles.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 9
Jammu And Kashmir View Result →
6.
Drinking Water Supply and Sanitation #10284437 Price Bid
Fixing Of Rate Contract For Repairs / Replacement To Electrical Equipment Installed At Different Wsss Of Phe Mechanical Sub-Division Bijbehara ( District Anantnag And Kulgam ) For The Financial Year 2023-24- 1 Mechanical Transportation, Loading, Unloading And Handling Of Various Items Such As Pump Parts, Motors, Starters, Voltage Stabilizers, Coil Assemblies, Welding Tools & Plant, Etc. Using Appropriate Means Of Transport As Under: 2 Private Car, Auto-Rickshaw Or Similar With 1.0 Km Lead 3 Extra Per Kilometer For Lead >1.0 Kms Upto 5.0 Kms 4 Extra Per Kilometer For Lead >5.0 Kms Upto 10.0 Kms 5 Extra Per Kilometer For Lead >10.0 Kms Upto 20.0 Kms 6 Extra Per Kilometer For Lead >20.0 Kms Upto 30.0 Kms 7 Load Carrier Auto, Mini Van Or Similar With 1.0 Km Lead 8 Extra Per Kilometer For Lead >1.0 Kms Upto 5.0 Kms 9 Extra Per Kilometer For Lead >5.0 Kms Upto 10.0 Kms 10 Extra Per Kilometer For Lead >10.0 Kms Upto 20.0 Kms 11 Extra Per Kilometer For Lead >20.0 Kms Upto 30.0 Kms 12 Mini Truck Like Tata Mobile, Bolero Camper Or Similar With 1.0 Km Lead 13 Extra Per Kilometer For Lead >1.0 Kms Upto 5.0 Kms 14 Extra Per Kilometer For Lead >5.0 Kms Upto 10.0 Kms 15 Extra Per Kilometer For Lead >10.0 Kms Upto 20.0 Kms 16 Extra Per Kilometer For Lead >20.0 Kms Upto 30.0 Kms 17 Voltage Stabilizersdismantling Of 415V 3-Ph Voltage Stabilizer By Way Of Opening Of Top Lid, Disassembling Of Voltage Regulator, Removing Of All Incoming And Outgoing Connections, Taking Out Of Damaged Copper Legs After Removal Of Core, Etc. The Job Includes Draining Out Of T. Oil And Its Safe Placement For Further Refilling. 18 Upto 50 Kva 19 >50 Upto 100Kva 20 >100Kva Upto 250 Kva 21 Greater Than 250 Kva 22 Assembling Of All Parts Of 3-Ph Voltage Stabilizer, Connecting Of Leads Of All Incoming And Outgoing Connections And Refilling Of Old Drained Out Of T. Oil 23 Upto 50 Kva 24 >50 Upto 100Kva 25 >100Kva Upto 250 Kva 26 Greater Than 250 Kva 27 Isolating And Disconnecting Of All Incoming And Outgoing Leads From Autotransformer Starter. Draining Out Transformer Oil From The Oil Tank And Collecting In A Suitable Vessel. Taking Out The Damaged Autotransformer Coil Assembly From Oil Tank. 28 >60 Upto 200 Hp 29 Providing Of Transformer Oil Conforming To Is 335 ( Preferred Make: Power Oil / Indian Oil Servo / Hpcl ) 30 Filtration Of Existing / Reclaimed T-Oil At Suitable Temperature ( Inclusive Of All Logistics And Charges For Filtration Plant, Etc ) ( Process Loss Maximum Of 5% Allowed ) 31 Rewinding Burnt / Damaged Windings Of Voltage Stabilizer Coil Assembly ( Comprising Of Three Limbs ) Using Superior Quality Copper Wire Of Proper Gauge As Per Requirement With Superior Insulation. ( Note: The Unserviceable Scrap Copper Generated Shall Be Property Of The Firm And Is Taken Into Account For Estimation Of Rates ) . 32 10Kva Rating 33 30Kva Rating 34 50Kva Rating 35 75Kva Rating 36 100Kva Rating 37 150Kva Rating 38 175Kva Rating 39 200Kva Rating 40 250Kva Rating 41 Removing Of Damagedplate Type Voltage Regulator Switch From 3 Phase , 415 ±15 % Volt Voltage Stabilizer And Providing And Fitting Of New Plate Type Voltage Regulator Switch Having Copper Contact Points With 6 Steps. The Job Includes Cost On Account Of Skilled / Semi-Skilled Labour Required For Work 42 10Kva Rating 43 30Kva Rating 44 50Kva Rating 45 75Kva Rating 46 100Kva Rating 47 150Kva Rating 48 175Kva Rating 49 200Kva Rating 50 250Kva Rating 51 Impregnation / Heat Treatment Ofwinding Assembly Of 3 Phase, 415 ±15 % Volt Voltage Stabilizerby Way Of Keeping It In An Electric Oven For About 24 Hours And At Approperate Temperature. 52 10Kva Rating 53 30Kva Rating 54 50Kva Rating 55 75Kva Rating 56 100Kva Rating 57 150Kva Rating 58 175Kva Rating 59 200Kva Rating 60 250Kva Rating 61 Removing Of Damaged Copper Connection Terminal Bolt With Washer And Nut From3 Phase, 415 ±15 % Volt Voltage Stabilizer And Providing And Fitting Of New Copper Connection Terminal Bolt With Nut And Washer. 62 10Kva Rating 63 30Kva Rating 64 50Kva Rating 65 75Kva Rating 66 100Kva Rating 67 150Kva Rating 68 175Kva Rating 69 200Kva Rating 70 250Kva Rating 71 500Kva Rating 72 Hiring Of Portable Welding Set / Soldering Equipment Etc. Excluding Power Charges 73 Arresting Of Leakage In, 3 Phase , 415 ±15 % Volt Voltage Stabilizer Tank Along With Radiator Fins / Tubesby Way Of Soldering / Welding At The Cracked Spot ( Average Length Of Spot = 1 Inch ) 74 Providing And Replacement Of Copper Contact Points On Regulator Plate 75 Providing And Fitting Of Lv Copper Terminal Connectors With Allied Insulation _ ( For Finished Weight Of The Connector ) 76 Starterisolating And Disconnecting Of All Incoming And Outgoing Leads From Autotransformer Starter. Draining Out Transformer Oil From The Oil Tank And Collecting In A Suitable Vessel. Taking Out The Damaged Autotransformer Coil Assembly From Oil Tank. 77 Upto 60 Hp Rating 78 >60 Upto 200 Hp 79 >200 Hp Upto 350 Hp 80 Greater Than 350 Hp 81 Fitting Of Autotransformer Coil Assembly In The Starter Oil Tank, Filling Of T.Oil In The Tank, Connecting All Leads And Load Testing Of The Starter. 82 Upto 60 Hp Rating 83 >60 Upto 200 Hp 84 >200 Hp Upto 350 Hp 85 Greater Than 350 Hp 86 Contactorsproviding And Fitting Of 3-Pole Contactor ( Ac-3 Duty ) With Specified Coil Voltage: 87 L&T Ml 1.5 88 L&T Ml 2 89 L&T Ml 3 90 L&T Ml 4 91 L&T Ml 6 92 L&T Ml 12 93 L&T Mnx 50 94 L&T Mnx 70 95 L&T Mnx 80 96 L&T Mnx 95 97 L&T Mnx 110 98 L&T Mnx 140 99 L&T Mnx 185 100 L&T Mnx 225 101 L&T Mnx 250 102 Mk1 103 Mk2 104 Mu1 105 Mu1h 106 Mu2 107 Mu3 108 Ml2w 109 Ml3w 110 Ml4w 111 Ml6w 112 Schneider Electric Lc1f265 ( Without Coil ) 113 Schneider Electric Lc1f330 ( Without Coil ) 114 Schneider Electric Lc1f400 ( Without Coil ) 115 Schneider Electric Lc1f630 ( Without Coil ) 116 32A Ac-3 Rating ( Siemens 3Tf / L&T Type Mo / Schneider ) 117 45A Ac-3 Rating With 2No + 2Nc Auxillary Contacts ( Siemens 3Tf / L&T Type Mo / Schneider ) 118 Providing And Fitting Of New Ac Coil With Specified Coil Voltage For Contactors: 119 9A To 45A Ac-3 Rating ( Siemens 3Tf / Equivalent ) 120 L&T Ml 2 / 3 121 L&T Ml 4 / 6 122 L&T Ml 10 / 12 123 L&T Mnx 50 / 70 / 80 124 L&T Mnx 95 / 110 / 140 125 L&T Mnx 185 / 225 / 250 126 L&T Mnx 300 / 400 127 L&T Mnx 550 / 650 128 Schneider Electric Lc1f185 / Lc1f225 129 Schneider Electric Lc1f265 / Lc1f330 130 Schneider Electric Lc1f400 131 Schneider Electric Lc1f630 132 Providing And Fitting Of New Contact Kit Set For Contactors 133 32A Ac-3 Rating ( Siemens 3Tf / Equivalent ) 134 L&T Ml 2 135 L&T Ml 3 136 L&T Ml 4 137 L&T Ml 6 138 L&T Ml 10 139 L&T Ml 12 140 Providing And Fitting Of Auxillary Contactors / Control Relay 141 L&T Mx0 Having 04 Contacts ( All Combinations ) For Ac Control 142 L&T Mx0 Having 04 Contacts ( All Combinations ) For Dc Control 143 L&T Ml ( 1No+1Nc ) Side Mounting Auxillary Contact Block 144 L&T Mnx / Mcx Front Mounting Type Having 04 Contacts ( All Combinations ) 145 Timing Relaysproviding, Fitting And Setting Up Of Single Range Auto Reset Synchronous On Delay Timer ( L&T Or Equivalent Make ) 146 Providing, Fitting And Setting Of Electropneumatic Timing Relay With Timing Range Upto 60S; Coil Voltage 415V Ac ( Bch Or Equivalent Make ) . 147 ( 2No + 2Nc ) Double Block; On Delay 148 ( 2No + 2Nc ) Double Block; On & Off Delay 149 Providing And Fitting Of Spares For Electropneumatic Timing Relay ( Bch Make Or Equivalent ) 150 ( 2No + 2Nc ) Contact Block 151 Magnetic Coil 415V Ac 152 Magnet Frame Assembly Without Coil 153 Providing, Fitting And Setting Of Din Mounted Electronic Timer ( L&T Gic Or Equivalent Make ) 154 Star Delta ( Range From 3S - 120S ) 240V Ac 155 Star Delta ( Range From 3S - 30S ) 240 - 415V Ac 156 On Delay ( 0.3S - 30Hrs ) 240V Ac 157 Thermal Overload Relayproviding, Fitting And Setting Of Thermal Overload Relay Of Specified Relay Range ( Make: L&T Mn2 ) 158 Relay Range In Between 0.2A To 15A 159 14-23A 160 20-33A 161 24-40A 162 Providing, Fitting And Setting Of Thermal Overload Relay Of Specified Relay Range ( Make: L&T Mn5 ) 163 20-33A 164 30-50A 165 36-60A 166 45-75A 167 66-110A 168 Providing, Fitting And Setting Of Thermal Overload Relay Of Specified Relay Range 169 L&T Ml1 ( Relay Range In Between 0.15A To 16A ) 170 L&T Ml2 / 3 ( Relay Ranges In Between 9A To 42A ) 171 Miscellaneous 172 Providing And Fitting Of Bakelite Connection Plate Minimum 10Mm Thick As Per Given Size For Autotransformer With Holes For Connection Studs Drilled At Requisite Spots 173 Complete Servicing Of Control Wiring Of Ats Including Checking, Tightening Of Connections, Tapping And Insulation As Per Requirement. 174 Complete Replacement Of Suitable Copper Control Wiring Of Ats Including Cable Ties, Connections, Tapping And Insulation As Per Requirement. 175 Oil Immersed Starter Sparesproviding And Replacement Of Operating Coil For Oil Immersed Semi-Automatic Starter, Upto 40Hp 176 Providing And Fitting Of Heavy Duty Contact Kit Set For Semi-Automatic / Fully Automatic Sd Oil Immersed Starters ( Set Of 03 Moving And 06 Stationary Contacts ) , Upto 40 Hp 177 Spares For Oil Immersed Manual Starters 178 Fixed Finger Contact 179 Moving Tip Contact 180 No Volt Coil 181 Moving Drum Contact ( Starters Upto 40Hp ) 182 Moving Drum Contact ( Starters > 40Hp ) 183 Base Plate Bakelite / Dmc ( Starters Upto 40Hp ) 184 Base Plate Bakelite / Dmc ( Starters > 40Hp ) 185 Steam Carrier Assembly ( Starters Upto 40Hp ) 186 Steam Carrier Assembly ( Starters > 40Hp ) 187 Sequence Shaft ( Starters Upto 40Hp ) 188 Sequence Shaft ( Starters > 40Hp ) 189 Bakelite Tube For Sequence Shaft ( Starters Upto 40Hp ) 190 Bakelite Tube For Sequence Shaft ( Starters > 40Hp ) 191 Trip Rod Assembly ( Starters Upto 40Hp ) 192 Trip Rod Assembly ( Starters > 40Hp ) 193 Lock Lever 194 Cam Assembly 195 Oil Dashpot Assembly 196 Overload Coil ( Set Of 03 Nos. ) Upto 20Hp 197 Overload Coil ( Set Of 03 Nos. ) 30- 40Hp 198 Overload Coil ( Set Of 03 Nos. ) 50- 60Hp 199 Overload Coil ( Set Of 03 Nos. ) 70- 80Hp 200 Overload Coil ( Set Of 03 Nos. ) 90- 100Hp 201 L&T Mu-G Submersible Pump Controller Sparesvolt-Ammeter 500V, 202 Electronic Star-Delta Timer 3-30S 203 Providing And Fitting Of Terminal Block 204 60A - 3 Way 205 100A - 3 Way 206 Single Phase Preventing Relay Sz5 Type 207 Single Phase Preventing Relay Sdz5 Type 208 Providing, Fitting And Setting Of Thermal Overload Relay Of Specified Relay Range ( Make: L&T ) 209 Mk1 ( All Ranges ) 210 Mu1 ( All Ranges ) 211 Mu2 Relays Of Following Ranges 212 6 -10 A, 9 - 14A 213 13 - 21A 214 15 - 25A 215 20 - 32A 216 24 - 38A 217 28 - 42A 218 Providing And Fitting Of Standard Operating Coil For Following Contactors 219 Mk1 / Mk2 220 Mu1 / Mu2 / Mu3 221 Providing And Fitting Of Contact Bridge Without Contact Of Following Contactors 222 Mk1 / Mk2 223 Mu1 / Mu2 / Mu3 224 Providing And Fitting Of Single Moving Contact Of Following Contactors 225 Mk1 226 Mk2 227 Mu1 228 Mu2 229 Mu3 230 Indicating Lamps 231 Rocker Switch 232 Rocker Switch ( Mug-G6 To Mug G20 ) 233 Rocker Switch ( Mug-G30 To Mug G75 ) 234 Voltage Selector Switch 235 30A Ammeter Spare For Mr-G Controller 236 Volt Ammeter ( 30A, 300V Ac ) For 3-30 Sec Or 12-20 Sec. 237 Electronic Star -Delta Timer For Mug Starters 238 Electronic Star -Delta Timer Type St100, 160 - 500V, For 3-30 Sec Or 12-20 Sec. 239 Providing And Fitting Of Mu Coil 240 / 360 / 415 V To Mug Submersible Starter 240 Providing And Fitting Of Mu1 / Mu1h / Mu2 / Mu3 Contact Bridge 241 Providing And Fitting Of Mu1 / Mu2 Relay Extension Job To Mug Submersible Starter 242 Providing And Fitting Of Mu1 / M, U1h / Mu2 / Mu3housing To Mug Submersible Starter 243 Providingand Fitting Of New Mug After Removing Old Damaged Ones 244 Mug 6, 6-10 Amp Relay 245 Mug 6, 9-14 Amp Relay 246 Mug 10, 13-21 Amp Relay 247 Mug 10, 20-32 Amp Relay 248 Mug 10, 28-42 Amp Relay 249 Mug 15, 11-18 Amp Relay 250 Mug 15, 13-22 Amp Relay 251 Mug 20, 9-14 Amp Relay 252 Mug 20H, 20-32 Amp Relay 253 Mug 20H, 28-42 Amp Relay 254 Mug 30, 20-33 Amp Relay 255 Mug 30, 30-50 Amp Relay 256 Mug 40, 30-50 Amp Relay 257 Mug 40, 36-60 Amp Relay 258 Mug 50, 36-50 Amp Relay 259 Mug 50, 45-75 Amp Relay 260 Mug 75, 45-75 Amp Relay 261 Mug 75, 66-110 Amp Relay 262 Mccbproviding And Fitting Of 3-Pole 415V Mccb With Thermal Magnetic Release Having 36Ka Breaking Capacity ( Ics= 100% Icu ) ( Make: L&T D-Sine Or Equivalent ) Having Max. Of Thermal Release Range As Under: 263 Upto And Including 100A ( Ics= 50% Icu ) 264 125A 265 160A 266 200A 267 250A 268 400A 269 Providing And Fitting Of 3-Pole 415V Mccb With Thermal Magnetic Release Having 50Ka Breaking Capacity Ics = 100% Icu ( Make: L&T D-Sine Or Equivalent ) Having Max. Of Thermal Release Range As Under: 270 125A 271 160A 272 200A 273 250A 274 400A 275 630A 276 Providing Of Set Of Spreader Terminals For Above 3-Pole Mccbs 277 100A 278 125A 279 250A 280 400A 281 630A 282 Providing And Fitting Of 4-Pole 415V Mccb With Thermal Magnetic Release Having 50Ka Breaking Capacity Ics = 100% Icu ( Make: L&T D-Sine Or Similar ) Having Max. Of Thermal Release Range As Under: 283 125A 284 160A 285 200A 286 250A 287 400A 288 630A 289 Spares For Acb ( L&T C-Power ) Providing And Fitting Of Pole Assembly For Draw Out Type Acb ( L&T C-Power ) 290 Upto 1250A 291 2000A 292 Providing And Fitting Of Arc Chute ( 440V ) For Acb ( L&T C-Power ) 293 Upto 1250A 294 1600 - 2000A 295 Providing And Fitting Of Jaw Contact For Acb ( L&T C-Power ) 296 630-1000A 297 1250A 298 1600A / 2000A 299 Providing And Fitting Of Fixed Arcing Contact For Acb ( L&T C-Power ) 300 800- 1600A 301 2000A 302 Providing And Fitting Of Moving Arcing Contact For Acb ( L&T C-Power ) 303 800- 2000A 304 Providing And Fitting Of Shunt Release For Acb ( L&T C-Power ) 305 Providing And Fitting Of Under Voltage Release For Acb ( L&T C-Power ) 306 Providing And Fitting Of Moving Arcing Contact For Acb ( L&T C-Power ) 307 Providing And Fitting Of Terminal Adaptor For Draw Out L&T C-Power Acb Of Ratings As Under: 308 Upto 800 - 1250A 309 1600 - 2000A 310 Providing And Fitting Of Thermal-Magnetic Release ( Type Dn1 ) For L&T C-Power Acb 311 Providing And Fitting Of Ct For Dn1 Type L&T C-Power Acb 312 800 / 1000A 313 1250 / 1600A 314 2000A 315 Providing And Fitting Of Main Spring For 3-Pole Acb ( L&T C-Power ) 316 800- 1600A 317 2000A 318 Providing Of Racking Handle For Draw-Out Type Acbs ( L&T C-Power ) Rating Upto 2000A 319 Providing And Replacement Of Spring Charging Motor ( Ac / Dc ) 320 Providing And Replacement Of Motor Limit Switch 321 Instrumentation And Panel Accessoriesproviding And Fitting Of 96X96 Flush Mounting 3-Phase Led Ammeter / Voltmeter Of Class 1 Accuracy ( Make: L&T / Schneider / Rishabh / Ae ) 322 Providing And Fitting Of Flush Type Analog Moving Iron Ac Meter As Under: ( Make: Rishabh / Ae / C&S / Bch ) 323 48X48mm 500V Voltmeter 324 96X96mm 500V Voltmeter 325 144X144mm 500V Voltmeter 326 96X96mm Ammeter ( 5A Ct Operated ) 327 Providing And Fitting Of Flush Type Frequency Meter With Range 45-55Hz: ( Make: Rishabh / Ae / L&T / Schneider / Bch ) 328 Providing And Fitting Of 10A Line Current Ammeter Selector Switch With Off ( Make: L&T / Rishabh / Ae / Teknic ) 329 Providing And Fitting Of 10A Voltmeter Selector Switch With Off ( Make: L&T / Rishabh / Ae / Teknic ) 330 Providing And Fitting Of Tape Insulated Ring Type Metering Current Transformers ( Ae / Rishabh / Crompton / Kilburn ) As Under: 331 100 / 5A Or 150 / 5A - Class 1 - Burden 5Va 332 200 / 5A - Class 1 - Burden 10Va 333 400 / 5A - Class 1 - Burden 15Va 334 600 / 5A - Class 1 - Burden 15Va 335 800 / 5A - Class 1 - Burden 15Va 336 1000 / 5A - Class 1 - Burden 15Va 337 2000 / 5A - Class 1 - Burden 15Va 338 Extra For 1A Secondary Upto 600 / 1A Over Corresponding Rate 339 Providing And Fitting Of Analog Vac Hour Meter ( Make: L&T Or Equivalent Make ) 340 Din Mounting Type 341 Flush Mounting Type 342 Providing And Fitting Of Flush Or Projecting Head Push Button With Contact Block ( L&T / Teknic / Abb / Bch / Schneider Or Any Other Reputed Make ) 343 Providing And Fitting Of Led Phase Indicator With Surge Protection ( L&T / Teknic / Abb / Bch / Schneider Or Any Other Reputed Make ) 344 Providing And Fitting 3 Phase, 3 / 4 Wire Adjustable Under & Over Voltage Monitoring Relay ( Minilec Vct D2 Or Equivalent ) 345 Providing, Fitting And Setting Of 415V Auto Reset Single Phase Preventor ( L&T / Minilec / Bch Or Equivalent Make ) 346 50V Or Less Unbalance & 1 C / Odin Mounted 347 50V Or Less Unbalance & 1 C / Opanel Wall Mounted 348 70V Or Less Unbalance & 2 C / Odin Mounted 349 Providing And Fitting Of 32A Dp Switch ( Anchor / Ssk Or Any Other Reputed Make ) 350 Providing Of Hrc Fuses ( 2A - 32A ) Ratings 351 Providing And Fitting Of Fuse Holders For Fuses Upto 32A Rating 352 Providing And Fixing Upvc Panel Trunking With Cover 353 15X15mm 354 25X25mm 355 Terminals / Lugsproviding And Crimping Of Various Aluminium Tube Lugs ( Dowells / Action / Or Any Other Reputed Make ) With Tapping, Insulation As Under: 356 16 Sq. Mm 357 25 Sq. Mm 358 35 Sq. Mm 359 50 Sq. Mm 360 70 Sq. Mm 361 95 Sq. Mm 362 120 Sq. Mm 363 150 Sq. Mm 364 185 Sq. Mm 365 225 Sq. Mm 366 240 Sq. Mm 367 300 Sq. Mm 368 Providing And Crimping Of Various Copper Tube Lugs ( Dowells / Action / Or Any Other Reputed Make ) With Tapping, Insulation As Under: 369 16 Sq. Mm 370 25 Sq. Mm 371 35 Sq. Mm 372 50 Sq. Mm 373 70 Sq. Mm 374 95 Sq. Mm 375 120 Sq. Mm 376 150 Sq. Mm 377 185 Sq. Mm 378 225 Sq. Mm 379 240 Sq. Mm 380 300 Sq. Mm 381 Cablesproviding And Fitting Of Pvc Insulated 1100V Flat 3-Core Industrial Copper Cable For Submersible Pump Motors ( Preferred Makes: Finolex / L&T / Havells / Kei / Polycab ) 382 1.5 Sqmm 383 2.5 Sqmm 384 4.0 Sqmm 385 6.0 Sqmm 386 10.0 Sqmm 387 16.0 Sqmm 388 25.0 Sqmm 389 35.0 Sqmm 390 Providing And Fitting Of Xlpe Insulated, 1100V Single Core Armoured Industrial Copper Cable As Under ( Preferred Make: Finolex / Gloster / Havells / Kei / Polycab ) 391 16.0 Sqmm 392 25 Sqmm 393 35 Sqmm 394 50 Sqmm 395 70 Sqmm 396 95 Sqmm 397 120 Sqmm 398 150 Sqmm 399 185 Sqmm 400 240 Sqmm 401 300 Sqmm 402 400 Sqmm 403 Providing And Fitting Of Xlpe Insulated, 1100V Single Core Industrial Armoured Aluminium Cable As Under ( Preferred Make: Finolex / Gloster / Havells / Kei / Polycab ) 404 16 Sqmm 405 25 Sqmm 406 35 Sqmm 407 50 Sqmm 408 70 Sqmm 409 95 Sqmm 410 120 Sqmm 411 150 Sqmm 412 185 Sqmm 413 240 Sqmm 414 300 Sqmm 415 Providing And Fitting Of Xlpe Insulated, 1100V 3.5-Core Industrial Armoured Aluminium Cable As Per Is 7098 ( Preferred Make: Finolex / Gloster / Havells / Kei / Polycab ) 416 25 Sqmm 417 35 Sqmm 418 50 Sqmm 419 70 Sqmm 420 95 Sqmm 421 120 Sqmm 422 150 Sqmm 423 185 Sqmm 424 240 Sqmm 425 300 Sqmm 426 Wiringproviding And Fitting Of Pvc Insulated 1100V Flexible Copper Cable ( Frls ) For Electrical Installations As Under ( Preferred Makes: Finolex / Anchor / L&T / Havells / Kei / Polycab ) 427 1.0 Sqmm 428 1.5 Sqmm 429 2.5 Sqmm 430 4.0 Sqmm 431 6.0 Sqmm 432 10.0 Sqmm 433 16.0 Sqmm 434 2X1.5 Sqmm 435 2X2.5 Sqmm 436 2X6 Sqmm ( Aluminium Unarmoured ) 437 Conduits 438 Providing And Fixing 25Mm Pvc Round Conduit ( Medium ) With Allied Pvc Fittings 439 Providing And Fixing Upvc Trunking 25X16mm With Allied Fittings 440 Providing And Fixing Polypropylene Corrugated Flexible Conduit 441 25Mm 442 32Mm 443 Providing And Fitting Perforated Ms Cable Trays Including Horizontal And Vertical Bends, Reducers, Tees, Cross Members And Other Accessories As Required And Duly Suspended From The Ceiling With Ms Suspenders Or Fixing On Cantilever Supports And Including Painting Etc As Required. 444 100 X 50 X 1.6Mm 445 150 X 50 X 1.6Mm 446 Electrical Fitingsproviding And Fitting Of Various Electrical Fittings As Under ( Preferred Makes: Anchor / Ssk / Havells ) 447 Switch-6A-Sp-1Way, 240V, 50 Hz, Ac. 448 Switch-6A-Sp-2Way, 240V, 50 Hz, Ac. 449 Cord Switches:- Providing And Fitting Of Cord Switch-6A-Sp-1Way, 240V, 50 Hz, Ac / Hanging Bell Push. 450 Bell Push 240V, 50 Hz, Ac. 451 6A Socket:- Providing And Fitting Of6a-2 / 3 Pin-Universal Socket, 240V, 50 Hz, Ac. 452 Neon Indicator 453 Mini Telephone Jack 454 Fan Regulator ( Mini ) With Rotary Step 455 Fan Regulator ( Deluxe ) With Rotary Step 456 Shuttered-3 Pin Socket And Switch ( Box / Recessed ) - 20A-Sp-1 Way, 230V 50 Hz, Ac. 457 Plug Top 15 / 16A 3 Pin ( Isi Marked ) 458 32A Tp Switch 415V With Neon 459 32A Dp Switch 240V With Neon 460 Surface Mounting Box For Switches As Follows: 461 1 Gang Box 462 2 Gang Box 463 3 Gang Box 464 4 Gang Box 465 5 Gang Box 466 6 Gang Box 467 7 Gang Box 468 4 Gang Box ( Double Domestic ) 469 Providing, Fixing, Testing Of 6A Ceiling Rose 470 Providing And Installation Of Pendant / Angle / Batten Holders 6A 240V 471 Providing And Installation Of Spn Sheet Steel Enclosed Distribution Boxes - Single Door ( Make: L&T / Legrand / Hager / Havells / Benlo ) 472 4 Way 473 8 Way 474 12 Way 475 16 Way 476 Providing And Installation Of ‘B’ Series Mcb 240V, 50Hz, 10Ka Suitable For Lighting And Other Domestic Loads ( Preferred Make: L&T / Legrand / Hager / Havells / Schneider ) 477 6-32A Sp 478 40A Sp 479 6-32A Dp 480 40A Dp 481 100A 4P Isolator 482 Providing And Installation Of Change Over Switches Of Metal Enclosure 240V 50Hz ( Preferred Make: Anchor / Ssk / Havells / L&T ) 483 2-Pole 16A 415V 484 2-Pole 32A 415V 485 4-Pole 32A 415V 486 4-Pole 63A 415V 487 4-Pole 100A 415V 488 Providing And Installation Of Busbar Chamber 3-Ph 4 Bar Heavy Duty Copper Strips With Rating As Under ( Preferred Make: Havells / Ssk / L&T ) 489 63A 415V 490 100A 415V 491 200A 415V 492 Manpower 493 Hiring Charges Of Electrician ( For Troubleshooting / Revamping Of Existing Electrical Fitting, Etc. Exclusive Of Specified Works ) : 494 Hiring Charges Of Labourer For Support Of Electrician 495 Excavating Trenches Of Required Width For Pipes, Cables, Etc In All Kinds Of Soil Including Excavation For Sockets And Dressing Of Sides, Ramming Of Bottoms, Depth Upto 1.5 M, Including Getting Out The Excavated Soil, And Then Returning The Soil As Required, In Layers Not Exceeding 20 Cm In Depth, Including Consolidating Each Deposited Layer By Ramming, Watering, Etc. And Disposing Of Surplus Excavated Soil As Directed, Within A Lead Of 50 M 496 Pipes, Cables Etc, Not Exceeding 80 Mm Dia. 497 Pipes, Cables Etc. Exceeding 80 Mm Dia. But Not Exceeding 300 Mm Dia 498 Pipes, Cables Etc. Exceeding 300 Mm Dia But Not Exceeding 600 Mm Dia 499 Pipes, Cables Etc. Exceeding 600 Mm Dia But Not Exceeding 1200 Mm Dia 500 Extra For Excavating Trenches For Pipes, Cables Etc. In All Kinds Of Soil For Depth Exceeding 1.5 M, But Not Exceeding 3M. ( Rate Is Over Corresponding Basic Item For Depth Upto 1.5 Metre ) . 501 Extra For Excavating Trenches For Pipes, Cables, Etc, In All Kinds Of Soil For Depth Exceeding 3 M In Depth, But Not Exceeding 4.5 M. ( Rate Is Over Corresponding Basic Item For Depth Upto 1.5 Metre. )
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 5
Jammu And Kashmir View Result →
7.
Drinking Water Supply and Sanitation #10284422 Price Bid
Fixing Of Rate Contract For Repairs/Replacement To Electrical Equipment Installed At Different Wsss Of Phe Mechanical Sub-Division Pampore (District Pulwama) For The Financial Year 2023-24- 1 Mechanical transportation, loading, unloading and handling of various items such as pump parts, motors, starters, voltage stabilizers, coil assemblies, welding tools & plant, etc. using appropriate means of transport as under: 2 Private car, auto-rickshaw or similar with 1.0 km lead 3 Extra per kilometer for lead >1.0 kms upto 5.0 kms 4 Extra per kilometer for lead >5.0 kms upto 10.0 kms 5 Extra per kilometer for lead >10.0 kms upto 20.0 kms 6 Extra per kilometer for lead >20.0 kms upto 30.0 kms 7 Load carrier auto, mini van or similar with 1.0 km lead 8 Extra per kilometer for lead >1.0 kms upto 5.0 kms 9 Extra per kilometer for lead >5.0 kms upto 10.0 kms 10 Extra per kilometer for lead >10.0 kms upto 20.0 kms 11 Extra per kilometer for lead >20.0 kms upto 30.0 kms 12 Mini truck like Tata mobile, Bolero Camper or similar with 1.0 km lead 13 Extra per kilometer for lead >1.0 kms upto 5.0 kms 14 Extra per kilometer for lead >5.0 kms upto 10.0 kms 15 Extra per kilometer for lead >10.0 kms upto 20.0 kms 16 Extra per kilometer for lead >20.0 kms upto 30.0 kms 17 VOLTAGE STABILIZERSDismantling of 415V 3-ph Voltage Stabilizer by way of opening of top lid, disassembling of voltage regulator, removing of all incoming and outgoing connections, taking out of damaged copper legs after removal of core, etc. The job includes draining out of T. Oil and its safe placement for further refilling. 18 upto 50 kVA 19 >50 upto 100kVA 20 >100kVA upto 250 kVA 21 Greater than 250 kVA 22 Assembling of all parts of 3-ph Voltage Stabilizer, connecting of leads of all incoming and outgoing connections and refilling of old drained out of T. Oil 23 upto 50 kVA 24 >50 upto 100kVA 25 >100kVA upto 250 kVA 26 Greater than 250 kVA 27 Isolating and disconnecting of all incoming and outgoing leads from autotransformer starter. Draining out transformer oil from the oil tank and collecting in a suitable vessel. Taking out the damaged autotransformer coil assembly from oil tank. 28 >60 upto 200 HP 29 Providing of transformer oil conforming to IS 335 (Preferred make: Power oil/ Indian Oil Servo/ HPCL) 30 Filtration of existing/ reclaimed T-oil at suitable temperature (inclusive of all logistics and charges for filtration plant, etc)(Process loss maximum of 5% allowed) 31 Rewinding burnt/ damaged windings of voltage stabilizer coil assembly (comprising of three limbs) using superior quality copper wire of proper gauge as per requirement with superior insulation. (Note: The unserviceable scrap copper generated shall be property of the firm and is taken into account for estimation of rates). 32 10kVA rating 33 30kVA rating 34 50kVA rating 35 75kVA rating 36 100kVA rating 37 150kVA rating 38 175kVA rating 39 200kVA rating 40 250kVA rating 41 Removing of damagedplate type voltage regulator switch from 3 phase , 415 ±15 % Volt voltage stabilizer and providing and fitting of new plate type voltage regulator switch having copper contact points with 6 steps. the job includes cost on account of skilled/semi-skilled labour required for work 42 10kVA rating 43 30kVA rating 44 50kVA rating 45 75kVA rating 46 100kVA rating 47 150kVA rating 48 175kVA rating 49 200kVA rating 50 250kVA rating 51 Impregnation/heat treatment ofwinding assembly of 3 phase, 415 ±15 % Volt voltage stabilizerby way of keeping it in an electric oven for about 24 hours and at approperate temperature. 52 10kVA rating 53 30kVA rating 54 50kVA rating 55 75kVA rating 56 100kVA rating 57 150kVA rating 58 175kVA rating 59 200kVA rating 60 250kVA rating 61 Removing of damaged copper connection terminal bolt with washer and nut from3 phase, 415 ±15 % Volt voltage stabilizer and providing and fitting of new copper connection terminal bolt with nut and washer. 62 10kVA rating 63 30kVA rating 64 50kVA rating 65 75kVA rating 66 100kVA rating 67 150kVA rating 68 175kVA rating 69 200kVA rating 70 250kVA rating 71 500kVA rating 72 Hiring of portable welding set /soldering equipment etc. excluding power charges 73 Arresting of leakage in, 3 phase , 415 ±15 % Volt voltage stabilizer tank along with radiator fins/tubesby way of soldering/ welding at the cracked spot (average length of spot = 1 inch) 74 Providing and replacement of copper contact points on regulator plate 75 Providing and Fitting of LV copper terminal connectors with allied insulation _ (for finished weight of the connector) 76 STARTERIsolating and disconnecting of all incoming and outgoing leads from autotransformer starter. Draining out transformer oil from the oil tank and collecting in a suitable vessel. Taking out the damaged autotransformer coil assembly from oil tank. 77 upto 60 HP rating 78 >60 upto 200 HP 79 >200 HP upto 350 HP 80 greater than 350 HP 81 Fitting of autotransformer coil assembly in the starter oil tank, filling of t.oil in the tank, connecting all leads and load testing of the starter. 82 upto 60 HP rating 83 >60 upto 200 HP 84 >200 HP upto 350 HP 85 greater than 350 HP 86 CONTACTORSProviding and fitting of 3-pole contactor (AC-3 duty) with specified coil voltage: 87 L&T ML 1.5 88 L&T ML 2 89 L&T ML 3 90 L&T ML 4 91 L&T ML 6 92 L&T ML 12 93 L&T MNX 50 94 L&T MNX 70 95 L&T MNX 80 96 L&T MNX 95 97 L&T MNX 110 98 L&T MNX 140 99 L&T MNX 185 100 L&T MNX 225 101 L&T MNX 250 102 MK1 103 MK2 104 MU1 105 MU1H 106 MU2 107 MU3 108 ML2W 109 ML3W 110 ML4W 111 ML6W 112 Schneider Electric LC1F265 (without coil) 113 Schneider Electric LC1F330 (without coil) 114 Schneider Electric LC1F400 (without coil) 115 Schneider Electric LC1F630 (without coil) 116 32A AC-3 rating (Siemens 3TF/ L&T Type MO/ Schneider) 117 45A AC-3 rating with 2NO + 2NC auxillary contacts (Siemens 3TF/ L&T Type MO/ Schneider) 118 Providing and fitting of new AC coil with specified coil voltage for contactors: 119 9A to 45A AC-3 rating (Siemens 3TF/ equivalent) 120 L&T ML 2/ 3 121 L&T ML 4/ 6 122 L&T ML 10/ 12 123 L&T MNX 50/ 70/ 80 124 L&T MNX 95/ 110/ 140 125 L&T MNX 185/ 225/ 250 126 L&T MNX 300/ 400 127 L&T MNX 550/ 650 128 Schneider Electric LC1F185/ LC1F225 129 Schneider Electric LC1F265/ LC1F330 130 Schneider Electric LC1F400 131 Schneider Electric LC1F630 132 Providing and fitting of new Contact kit set for contactors 133 32A AC-3 rating (Siemens 3TF/equivalent) 134 L&T ML 2 135 L&T ML 3 136 L&T ML 4 137 L&T ML 6 138 L&T ML 10 139 L&T ML 12 140 Providing and fitting of auxillary contactors/ control relay 141 L&T MX0 having 04 contacts (all combinations) for AC control 142 L&T MX0 having 04 contacts (all combinations) for DC control 143 L&T ML (1NO+1NC) side mounting auxillary contact block 144 L&T MNX/MCX front mounting type having 04 contacts (all combinations) 145 TIMING RELAYSProviding, fitting and setting up of single range auto reset synchronous ON delay timer (L&T or equivalent make) 146 Providing, fitting and setting of electropneumatic timing relay with timing range upto 60s; coil voltage 415V AC (BCH or equivalent make) . 147 (2NO + 2NC) double block; ON delay 148 (2NO + 2NC) double block; ON & OFF delay 149 Providing and fitting of spares for electropneumatic timing relay (BCH make or equivalent) 150 (2NO + 2NC) contact block 151 Magnetic coil 415V AC 152 Magnet frame assembly without coil 153 Providing, fitting and setting of DIN mounted electronic Timer (L&T GIC or equivalent make) 154 Star Delta (range from 3s - 120s)240V AC 155 Star Delta (range from 3s - 30s)240 - 415V AC 156 ON delay (0.3s - 30hrs) 240V AC 157 THERMAL OVERLOAD RELAYProviding, fitting and setting of thermal overload relay of specified relay range(Make: L&T MN2) 158 Relay range in between 0.2A to 15A 159 14-23A 160 20-33A 161 24-40A 162 Providing, fitting and setting of thermal overload relay of specified relay range(Make: L&T MN5) 163 20-33A 164 30-50A 165 36-60A 166 45-75A 167 66-110A 168 Providing, fitting and setting of thermal overload relay of specified relay range 169 L&T ML1 (Relay range in between 0.15A to 16A) 170 L&T ML2/3 (Relay ranges in between 9A to 42A) 171 MISCELLANEOUS 172 Providing and fitting of bakelite connection plate minimum 10mm thick as per given size for autotransformer with holes for connection studs drilled at requisite spots 173 Complete servicing of control wiring of ATS including checking, tightening of connections, tapping and insulation as per requirement. 174 Complete replacement of suitable copper control wiring of ATS including cable ties, connections, tapping and insulation as per requirement. 175 OIL IMMERSED STARTER SPARESProviding and replacement of operating coil for oil immersed semi-automatic starter, upto 40HP 176 Providing and fitting of heavy duty contact kit set for semi-automatic/ fully automatic SD oil immersed starters (set of 03 moving and 06 stationary contacts), upto 40 HP 177 Spares for oil immersed manual starters 178 Fixed finger contact 179 Moving tip contact 180 No volt coil 181 Moving drum contact (starters upto 40HP) 182 Moving drum contact (starters > 40HP) 183 Base plate Bakelite/ DMC (starters upto 40HP) 184 Base plate Bakelite/ DMC (starters > 40HP) 185 Steam carrier assembly (starters upto 40HP) 186 Steam carrier assembly (starters > 40HP) 187 Sequence shaft (starters upto 40HP) 188 Sequence shaft (starters > 40HP) 189 Bakelite tube for Sequence shaft (starters upto 40HP) 190 Bakelite tube for Sequence shaft (starters > 40HP) 191 Trip rod assembly (starters upto 40HP) 192 Trip rod assembly (starters > 40HP) 193 Lock lever 194 Cam assembly 195 Oil dashpot assembly 196 Overload coil (set of 03 nos.) upto 20HP 197 Overload coil (set of 03 nos.) 30- 40HP 198 Overload coil (set of 03 nos.) 50- 60HP 199 Overload coil (set of 03 nos.) 70- 80HP 200 Overload coil (set of 03 nos.) 90- 100HP 201 L&T MU-G SUBMERSIBLE PUMP CONTROLLER SPARESVolt-Ammeter 500V, 202 Electronic Star-Delta Timer 3-30s 203 Providing and fitting of Terminal Block 204 60A - 3 way 205 100A - 3 way 206 Single phase preventing relay Sz5 type 207 Single phase preventing relay SDz5 type 208 Providing, fitting and setting of thermal overload relay of specified relay range(Make: L&T) 209 MK1 (all ranges) 210 MU1 (all ranges) 211 MU2 relays of following ranges 212 6 -10 A, 9 - 14A 213 13 - 21A 214 15 - 25A 215 20 - 32A 216 24 - 38A 217 28 - 42A 218 Providing and fitting of standard operating coil for following contactors 219 MK1/ MK2 220 MU1/ MU2/ MU3 221 Providing and fitting of contact bridge without contact of following contactors 222 MK1/ MK2 223 MU1/ MU2/ MU3 224 Providing and fitting of single moving contact of following contactors 225 MK1 226 MK2 227 MU1 228 MU2 229 MU3 230 Indicating lamps 231 Rocker switch 232 Rocker switch (MUG-G6 to MUG G20) 233 Rocker switch (MUG-G30 to MUG G75) 234 Voltage Selector switch 235 30A Ammeter Spare for MR-G Controller 236 Volt Ammeter (30A, 300V AC) for 3-30 sec or 12-20 sec. 237 Electronic star -Delta timer for MUG Starters 238 Electronic star -Delta timer type ST100, 160 - 500V, for 3-30 sec or 12-20 sec. 239 Providing and fitting of MU Coil 240/360/415 V to MUG submersible Starter 240 Providing and fitting of MU1/MU1H/MU2/MU3 contact bridge 241 Providing and fitting of MU1/MU2 Relay extension job to MUG submersible starter 242 Providing and fitting of MU1/M,U1H/MU2/MU3housing To MUG submersible starter 243 MCCBProviding and fitting of 3-pole 415V MCCB with thermal magnetic release having 36kA breaking capacity (Ics= 100% Icu) (Make: L&T d-sine or equivalent) having max. of thermal release range as under: 244 upto and including 100A (Ics= 50% Icu) 245 125A 246 160A 247 200A 248 250A 249 400A 250 Providing and fitting of 3-pole 415V MCCB with thermal magnetic release having 50kA breaking capacity Ics = 100% Icu (Make: L&T d-sine or equivalent) Having max. of thermal release range as under: 251 125A 252 160A 253 200A 254 250A 255 Providing of set of spreader terminals for above 3-pole MCCBs 256 100A 257 125A 258 250A 259 400A 260 630A 261 Providing and fitting of 4-pole 415V MCCB with thermal magnetic release having 50kA breaking capacity Ics = 100% Icu (Make: L&T d-sine or similar) Having max. of thermal release range as under: 262 125A 263 160A 264 200A 265 250A 266 SPARES FOR ACB (L&T C-POWER)Providing and fitting of pole assembly for draw out type ACB (L&T C-power) 267 upto 1250A 268 2000A 269 Providing and fitting of Arc Chute (440V) for ACB (L&T C-power) 270 upto 1250A 271 1600 - 2000A 272 Providing and fitting of Jaw contact for ACB (L&T C-power) 273 630-1000A 274 1250A 275 1600A/ 2000A 276 Providing and fitting of Fixed arcing contact for ACB (L&T C-power) 277 800- 1600A 278 2000A 279 Providing and fitting of Moving arcing contact for ACB (L&T C-power) 280 800- 2000A 281 Providing and fitting of Shunt release for ACB (L&T C-power) 282 Providing and fitting of Under Voltage Release for ACB (L&T C-power) 283 Providing and fitting of Moving arcing contact for ACB (L&T C-power) 284 Providing and fitting of Terminal Adaptor for Draw out L&T C-POWER ACB of ratings as under: 285 upto 800 - 1250A 286 1600 - 2000A 287 Providing and fitting of thermal-Magnetic Release (type DN1) for L&T C-power ACB 288 Providing and fitting of CT for DN1 type L&T C-power ACB 289 800/ 1000A 290 1250/ 1600A 291 2000A 292 Providing and fitting of main spring for 3-pole ACB (L&T C-power) 293 800- 1600A 294 2000A 295 Providing of racking handle for draw-out type ACBs (L&T C-power) rating upto 2000A 296 Providing and replacement of spring charging motor (AC/ DC) 297 Providing and replacement of motor limit switch 298 INSTRUMENTATION AND PANEL ACCESSORIESProviding and fitting of 96x96 flush mounting 3-phase LED ammeter/ voltmeter of Class 1 accuracy (Make: L&T/ Schneider/ Rishabh/ AE) 299 Providing and fitting of flush type analog moving iron AC meter as under:(Make: Rishabh/ AE/ C&S/ BCH) 300 48x48mm 500V voltmeter 301 96x96mm 500V voltmeter 302 144x144mm 500V voltmeter 303 96x96mm ammeter (5A CT operated) 304 Providing and fitting of flush type frequency meter with range 45-55Hz:(Make: Rishabh/ AE/ L&T/ Schneider/ BCH) 305 Providing and fitting of 10A line current ammeter selector switch with OFF (Make: L&T/Rishabh/ AE/ Teknic) 306 Providing and fitting of 10A voltmeter selector switch with OFF(Make: L&T/ Rishabh/ AE/ Teknic) 307 Providing and fitting of tape insulated ring type metering current transformers (AE/ Rishabh/ Crompton/ Kilburn) as under: 308 100/5A or 150/5A - Class 1 - Burden 5VA 309 200/5A - Class 1 - Burden 10VA 310 400/5A - Class 1 - Burden 15VA 311 600/5A - Class 1 - Burden 15VA 312 800/5A - Class 1 - Burden 15VA 313 1000/5A - Class 1 - Burden 15VA 314 2000/5A - Class 1 - Burden 15VA 315 Extra for 1A secondary upto 600/1A over corresponding rate 316 Providing and fitting of analog VAC hour meter(Make: L&T or equivalent make) 317 DIN mounting type 318 Flush mounting type 319 Providing and fitting of flush or projecting head push button with contact block (L&T/ Teknic/ ABB/ BCH/ Schneider or any other reputed make) 320 Providing and fitting of LED phase indicator with surge protection (L&T/ Teknic/ ABB/ BCH/ Schneider or any other reputed make) 321 Providing and fitting 3 Phase, 3/4 Wire adjustable Under & Over Voltage monitoring relay (Minilec VCT D2 or equivalent) 322 Providing, fitting and setting of 415V auto reset single phase preventor (L&T/ Minilec/ BCH or equivalent make) 323 50V or less unbalance & 1 C/ODIN mounted 324 50V or less unbalance & 1 C/OPanel wall mounted 325 70V or less unbalance & 2 C/ODIN mounted 326 Providing and fitting of 32A DP switch (Anchor/ SSK or any other reputed make) 327 Providing of HRC fuses (2A - 32A) ratings 328 Providing and fitting of Fuse holders for fuses upto 32A rating 329 Providing and fixing uPVC panel trunking with cover 330 15x15mm 331 25x25mm 332 TERMINALS/LUGSProviding and crimping of various aluminium tube lugs (Dowells/ Action/ or any other reputed make) with tapping, insulation as under: 333 16 sq. mm 334 25 sq. mm 335 35 sq. mm 336 50 sq. mm 337 70 sq. mm 338 95 sq. mm 339 120 sq. mm 340 150 sq. mm 341 185 sq. mm 342 225 sq. mm 343 240 sq. mm 344 300 sq. mm 345 Providing and crimping of various copper tube lugs (Dowells/ Action/ or any other reputed make) with tapping, insulation as under: 346 16 sq. mm 347 25 sq. mm 348 35 sq. mm 349 50 sq. mm 350 70 sq. mm 351 95 sq. mm 352 120 sq. mm 353 150 sq. mm 354 185 sq. mm 355 225 sq. mm 356 240 sq. mm 357 300 sq. mm 358 CABLESProviding and fitting of PVC insulated 1100V flat 3-core industrial copper cable for submersible pump motors (Preferred makes: Finolex/ L&T/ Havells/ KEI/ Polycab) 359 1.5 sqmm 360 2.5 sqmm 361 4.0 sqmm 362 6.0 sqmm 363 10.0 sqmm 364 16.0 sqmm 365 25.0 sqmm 366 35.0 sqmm 367 Providing and fitting of XLPE insulated, 1100V single core armoured industrial copper cable as under (Preferred make: Finolex/ Gloster/ Havells/ KEI/ Polycab) 368 16.0 sqmm 369 25 sqmm 370 35 sqmm 371 50 sqmm 372 70 sqmm 373 95 sqmm 374 120 sqmm 375 150 sqmm 376 185 sqmm 377 240 sqmm 378 300 sqmm 379 400 sqmm 380 Providing and fitting of XLPE insulated, 1100V single core industrial armoured aluminium cable as under (Preferred make: Finolex/ Gloster/ Havells/ KEI/ Polycab) 381 16 sqmm 382 25 sqmm 383 35 sqmm 384 50 sqmm 385 70 sqmm 386 95 sqmm 387 120 sqmm 388 150 sqmm 389 185 sqmm 390 240 sqmm 391 300 sqmm 392 Providing and fitting of XLPE insulated, 1100V 3.5-core industrial armoured aluminium cable as per IS 7098 (Preferred make: Finolex/ Gloster/ Havells/ KEI/ Polycab) 393 25 sqmm 394 35 sqmm 395 50 sqmm 396 70 sqmm 397 95 sqmm 398 120 sqmm 399 150 sqmm 400 185 sqmm 401 240 sqmm 402 300 sqmm 403 Providing and installation of SPN sheet steel enclosed Distribution boxes - Single door (Make: L&T/ Legrand/ Hager/ Havells/ Benlo) 404 4 way 405 8 way 406 12 way 407 16 way 408 Providing and installation of ‘B’ Series MCB 240V, 50Hz, 10kA Suitable for lighting and other domestic loads (Preferred Make: L&T/ Legrand/ Hager/ Havells/ Schneider) 409 6-32A SP 410 40A SP 411 6-32A DP 412 40A DP 413 100A 4P isolator 414 Providing and installation of Change over switches of metal enclosure 240v 50Hz (Preferred make: Anchor/ SSK/ Havells/ L&T) 415 2-pole 16A 415V 416 2-pole 32A 415V 417 4-pole 32A 415V 418 4-pole 63A 415V 419 4-pole 100A 415V 420 Providing and installation of Busbar chamber 3-ph 4 bar heavy duty copper strips with rating as under(Preferred make: Havells/ SSK/ L&T) 421 63A 415V 422 100A 415V 423 200A 415V 424 MANPOWER 425 Hiring charges of Electrician (for troubleshooting/ revamping of existing electrical fitting, etc. exclusive of specified works): 426 Hiring charges of Labourer for support of electrician 427 Excavating trenches of required width for pipes, cables, etc in all kinds of soil including excavation for sockets and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m 428 Pipes, cables etc, not exceeding 80 mm dia. 429 Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia 430 Pipes, cables etc. exceeding 300 mm dia but not exceeding 600 mm dia 431 Pipes, cables etc. exceeding 600 mm dia but not exceeding 1200 mm dia 432 Extra for excavating trenches for pipes, cables etc. in all kinds of soil for depth exceeding 1.5 m, but not exceeding 3m. (Rate is over corresponding basic item for depth upto 1.5 metre). 433 Extra for excavating trenches for pipes, cables, etc, in all kinds of soil for depth exceeding 3 m in depth, but not exceeding 4.5 m. (Rate is over corresponding basic item for depth upto 1.5 metre.)
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 5
Jammu And Kashmir View Result →
8.
Health and Family Welfare #10284420 Price Bid
Fixing Of Rate Contract For Repairs / Replacement To Electrical Equipment Installed At Different Wsss Of Phe Mechanical Sub-Division Qazigund ( District Anantnag And Kulgam ) For The Financial Year 2023-24- 1 Mechanical Transportation, Loading, Unloading And Handling Of Various Items Such As Pump Parts, Motors, Starters, Voltage Stabilizers, Coil Assemblies, Welding Tools & Plant, Etc. Using Appropriate Means Of Transport As Under: 2 Private Car, Auto-Rickshaw Or Similar With 1.0 Km Lead 3 Extra Per Kilometer For Lead >1.0 Kms Upto 5.0 Kms 4 Extra Per Kilometer For Lead >5.0 Kms Upto 10.0 Kms 5 Extra Per Kilometer For Lead >10.0 Kms Upto 20.0 Kms 6 Extra Per Kilometer For Lead >20.0 Kms Upto 30.0 Kms 7 Load Carrier Auto, Mini Van Or Similar With 1.0 Km Lead 8 Extra Per Kilometer For Lead >1.0 Kms Upto 5.0 Kms 9 Extra Per Kilometer For Lead >5.0 Kms Upto 10.0 Kms 10 Extra Per Kilometer For Lead >10.0 Kms Upto 20.0 Kms 11 Extra Per Kilometer For Lead >20.0 Kms Upto 30.0 Kms 12 Mini Truck Like Tata Mobile, Bolero Camper Or Similar With 1.0 Km Lead 13 Extra Per Kilometer For Lead >1.0 Kms Upto 5.0 Kms 14 Extra Per Kilometer For Lead >5.0 Kms Upto 10.0 Kms 15 Extra Per Kilometer For Lead >10.0 Kms Upto 20.0 Kms 16 Extra Per Kilometer For Lead >20.0 Kms Upto 30.0 Kms 17 Voltage Stabilizersdismantling Of 415V 3-Ph Voltage Stabilizer By Way Of Opening Of Top Lid, Disassembling Of Voltage Regulator, Removing Of All Incoming And Outgoing Connections, Taking Out Of Damaged Copper Legs After Removal Of Core, Etc. The Job Includes Draining Out Of T. Oil And Its Safe Placement For Further Refilling. 18 Upto 50 Kva 19 >50 Upto 100Kva 20 >100Kva Upto 250 Kva 21 Greater Than 250 Kva 22 Assembling Of All Parts Of 3-Ph Voltage Stabilizer, Connecting Of Leads Of All Incoming And Outgoing Connections And Refilling Of Old Drained Out Of T. Oil 23 Upto 50 Kva 24 >50 Upto 100Kva 25 >100Kva Upto 250 Kva 26 Greater Than 250 Kva 27 Isolating And Disconnecting Of All Incoming And Outgoing Leads From Autotransformer Starter. Draining Out Transformer Oil From The Oil Tank And Collecting In A Suitable Vessel. Taking Out The Damaged Autotransformer Coil Assembly From Oil Tank. 28 >60 Upto 200 Hp 29 Providing Of Transformer Oil Conforming To Is 335 ( Preferred Make: Power Oil / Indian Oil Servo / Hpcl ) 30 Filtration Of Existing / Reclaimed T-Oil At Suitable Temperature ( Inclusive Of All Logistics And Charges For Filtration Plant, Etc ) ( Process Loss Maximum Of 5% Allowed ) 31 Rewinding Burnt / Damaged Windings Of Voltage Stabilizer Coil Assembly ( Comprising Of Three Limbs ) Using Superior Quality Copper Wire Of Proper Gauge As Per Requirement With Superior Insulation. ( Note: The Unserviceable Scrap Copper Generated Shall Be Property Of The Firm And Is Taken Into Account For Estimation Of Rates ) . 32 10Kva Rating 33 30Kva Rating 34 50Kva Rating 35 75Kva Rating 36 100Kva Rating 37 150Kva Rating 38 175Kva Rating 39 200Kva Rating 40 250Kva Rating 41 Removing Of Damagedplate Type Voltage Regulator Switch From 3 Phase , 415 ±15 % Volt Voltage Stabilizer And Providing And Fitting Of New Plate Type Voltage Regulator Switch Having Copper Contact Points With 6 Steps. The Job Includes Cost On Account Of Skilled / Semi-Skilled Labour Required For Work 42 10Kva Rating 43 30Kva Rating 44 50Kva Rating 45 75Kva Rating 46 100Kva Rating 47 150Kva Rating 48 175Kva Rating 49 200Kva Rating 50 250Kva Rating 51 Impregnation / Heat Treatment Ofwinding Assembly Of 3 Phase, 415 ±15 % Volt Voltage Stabilizerby Way Of Keeping It In An Electric Oven For About 24 Hours And At Approperate Temperature. 52 10Kva Rating 53 30Kva Rating 54 50Kva Rating 55 75Kva Rating 56 100Kva Rating 57 150Kva Rating 58 175Kva Rating 59 200Kva Rating 60 250Kva Rating 61 Removing Of Damaged Copper Connection Terminal Bolt With Washer And Nut From3 Phase, 415 ±15 % Volt Voltage Stabilizer And Providing And Fitting Of New Copper Connection Terminal Bolt With Nut And Washer. 62 10Kva Rating 63 30Kva Rating 64 50Kva Rating 65 75Kva Rating 66 100Kva Rating 67 150Kva Rating 68 175Kva Rating 69 200Kva Rating 70 250Kva Rating 71 500Kva Rating 72 Hiring Of Portable Welding Set / Soldering Equipment Etc. Excluding Power Charges 73 Arresting Of Leakage In, 3 Phase , 415 ±15 % Volt Voltage Stabilizer Tank Along With Radiator Fins / Tubesby Way Of Soldering / Welding At The Cracked Spot ( Average Length Of Spot = 1 Inch ) 74 Providing And Replacement Of Copper Contact Points On Regulator Plate 75 Providing And Fitting Of Lv Copper Terminal Connectors With Allied Insulation _ ( For Finished Weight Of The Connector ) 76 Starterisolating And Disconnecting Of All Incoming And Outgoing Leads From Autotransformer Starter. Draining Out Transformer Oil From The Oil Tank And Collecting In A Suitable Vessel. Taking Out The Damaged Autotransformer Coil Assembly From Oil Tank. 77 Upto 60 Hp Rating 78 >60 Upto 200 Hp 79 >200 Hp Upto 350 Hp 80 Greater Than 350 Hp 81 Fitting Of Autotransformer Coil Assembly In The Starter Oil Tank, Filling Of T.Oil In The Tank, Connecting All Leads And Load Testing Of The Starter. 82 Upto 60 Hp Rating 83 >60 Upto 200 Hp 84 >200 Hp Upto 350 Hp 85 Greater Than 350 Hp 86 Contactorsproviding And Fitting Of 3-Pole Contactor ( Ac-3 Duty ) With Specified Coil Voltage: 87 L&T Ml 1.5 88 L&T Ml 2 89 L&T Ml 3 90 L&T Ml 4 91 L&T Ml 6 92 L&T Ml 12 93 L&T Mnx 50 94 L&T Mnx 70 95 L&T Mnx 80 96 L&T Mnx 95 97 L&T Mnx 110 98 L&T Mnx 140 99 L&T Mnx 185 100 L&T Mnx 225 101 L&T Mnx 250 102 Mk1 103 Mk2 104 Mu1 105 Mu1h 106 Mu2 107 Mu3 108 Ml2w 109 Ml3w 110 Ml4w 111 Ml6w 112 Schneider Electric Lc1f265 ( Without Coil ) 113 Schneider Electric Lc1f330 ( Without Coil ) 114 Schneider Electric Lc1f400 ( Without Coil ) 115 Schneider Electric Lc1f630 ( Without Coil ) 116 32A Ac-3 Rating ( Siemens 3Tf / L&T Type Mo / Schneider ) 117 45A Ac-3 Rating With 2No + 2Nc Auxillary Contacts ( Siemens 3Tf / L&T Type Mo / Schneider ) 118 Providing And Fitting Of New Ac Coil With Specified Coil Voltage For Contactors: 119 9A To 45A Ac-3 Rating ( Siemens 3Tf / Equivalent ) 120 L&T Ml 2 / 3 121 L&T Ml 4 / 6 122 L&T Ml 10 / 12 123 L&T Mnx 50 / 70 / 80 124 L&T Mnx 95 / 110 / 140 125 L&T Mnx 185 / 225 / 250 126 L&T Mnx 300 / 400 127 L&T Mnx 550 / 650 128 Schneider Electric Lc1f185 / Lc1f225 129 Schneider Electric Lc1f265 / Lc1f330 130 Schneider Electric Lc1f400 131 Schneider Electric Lc1f630 132 Providing And Fitting Of New Contact Kit Set For Contactors 133 32A Ac-3 Rating ( Siemens 3Tf / Equivalent ) 134 L&T Ml 2 135 L&T Ml 3 136 L&T Ml 4 137 L&T Ml 6 138 L&T Ml 10 139 L&T Ml 12 140 Providing And Fitting Of Auxillary Contactors / Control Relay 141 L&T Mx0 Having 04 Contacts ( All Combinations ) For Ac Control 142 L&T Mx0 Having 04 Contacts ( All Combinations ) For Dc Control 143 L&T Ml ( 1No+1Nc ) Side Mounting Auxillary Contact Block 144 L&T Mnx / Mcx Front Mounting Type Having 04 Contacts ( All Combinations ) 145 Timing Relaysproviding, Fitting And Setting Up Of Single Range Auto Reset Synchronous On Delay Timer ( L&T Or Equivalent Make ) 146 Providing, Fitting And Setting Of Electropneumatic Timing Relay With Timing Range Upto 60S; Coil Voltage 415V Ac ( Bch Or Equivalent Make ) . 147 ( 2No + 2Nc ) Double Block; On Delay 148 ( 2No + 2Nc ) Double Block; On & Off Delay 149 Providing And Fitting Of Spares For Electropneumatic Timing Relay ( Bch Make Or Equivalent ) 150 ( 2No + 2Nc ) Contact Block 151 Magnetic Coil 415V Ac 152 Magnet Frame Assembly Without Coil 153 Providing, Fitting And Setting Of Din Mounted Electronic Timer ( L&T Gic Or Equivalent Make ) 154 Star Delta ( Range From 3S - 120S ) 240V Ac 155 Star Delta ( Range From 3S - 30S ) 240 - 415V Ac 156 On Delay ( 0.3S - 30Hrs ) 240V Ac 157 Thermal Overload Relayproviding, Fitting And Setting Of Thermal Overload Relay Of Specified Relay Range ( Make: L&T Mn2 ) 158 Relay Range In Between 0.2A To 15A 159 14-23A 160 20-33A 161 24-40A 162 Providing, Fitting And Setting Of Thermal Overload Relay Of Specified Relay Range ( Make: L&T Mn5 ) 163 20-33A 164 30-50A 165 36-60A 166 45-75A 167 66-110A 168 Providing, Fitting And Setting Of Thermal Overload Relay Of Specified Relay Range 169 L&T Ml1 ( Relay Range In Between 0.15A To 16A ) 170 L&T Ml2 / 3 ( Relay Ranges In Between 9A To 42A ) 171 Miscellaneous 172 Providing And Fitting Of Bakelite Connection Plate Minimum 10Mm Thick As Per Given Size For Autotransformer With Holes For Connection Studs Drilled At Requisite Spots 173 Complete Servicing Of Control Wiring Of Ats Including Checking, Tightening Of Connections, Tapping And Insulation As Per Requirement. 174 Complete Replacement Of Suitable Copper Control Wiring Of Ats Including Cable Ties, Connections, Tapping And Insulation As Per Requirement. 175 Oil Immersed Starter Sparesproviding And Replacement Of Operating Coil For Oil Immersed Semi-Automatic Starter, Upto 40Hp 176 Providing And Fitting Of Heavy Duty Contact Kit Set For Semi-Automatic / Fully Automatic Sd Oil Immersed Starters ( Set Of 03 Moving And 06 Stationary Contacts ) , Upto 40 Hp 177 Spares For Oil Immersed Manual Starters 178 Fixed Finger Contact 179 Moving Tip Contact 180 No Volt Coil 181 Moving Drum Contact ( Starters Upto 40Hp ) 182 Moving Drum Contact ( Starters > 40Hp ) 183 Base Plate Bakelite / Dmc ( Starters Upto 40Hp ) 184 Base Plate Bakelite / Dmc ( Starters > 40Hp ) 185 Steam Carrier Assembly ( Starters Upto 40Hp ) 186 Steam Carrier Assembly ( Starters > 40Hp ) 187 Sequence Shaft ( Starters Upto 40Hp ) 188 Sequence Shaft ( Starters > 40Hp ) 189 Bakelite Tube For Sequence Shaft ( Starters Upto 40Hp ) 190 Bakelite Tube For Sequence Shaft ( Starters > 40Hp ) 191 Trip Rod Assembly ( Starters Upto 40Hp ) 192 Trip Rod Assembly ( Starters > 40Hp ) 193 Lock Lever 194 Cam Assembly 195 Oil Dashpot Assembly 196 Overload Coil ( Set Of 03 Nos. ) Upto 20Hp 197 Overload Coil ( Set Of 03 Nos. ) 30- 40Hp 198 Overload Coil ( Set Of 03 Nos. ) 50- 60Hp 199 Overload Coil ( Set Of 03 Nos. ) 70- 80Hp 200 Overload Coil ( Set Of 03 Nos. ) 90- 100Hp 201 L&T Mu-G Submersible Pump Controller Sparesvolt-Ammeter 500V, 202 Electronic Star-Delta Timer 3-30S 203 Providing And Fitting Of Terminal Block 204 60A - 3 Way 205 100A - 3 Way 206 Single Phase Preventing Relay Sz5 Type 207 Single Phase Preventing Relay Sdz5 Type 208 Providing, Fitting And Setting Of Thermal Overload Relay Of Specified Relay Range ( Make: L&T ) 209 Mk1 ( All Ranges ) 210 Mu1 ( All Ranges ) 211 Mu2 Relays Of Following Ranges 212 6 -10 A, 9 - 14A 213 13 - 21A 214 15 - 25A 215 20 - 32A 216 24 - 38A 217 28 - 42A 218 Providing And Fitting Of Standard Operating Coil For Following Contactors 219 Mk1 / Mk2 220 Mu1 / Mu2 / Mu3 221 Providing And Fitting Of Contact Bridge Without Contact Of Following Contactors 222 Mk1 / Mk2 223 Mu1 / Mu2 / Mu3 224 Providing And Fitting Of Single Moving Contact Of Following Contactors 225 Mk1 226 Mk2 227 Mu1 228 Mu2 229 Mu3 230 Indicating Lamps 231 Rocker Switch 232 Rocker Switch ( Mug-G6 To Mug G20 ) 233 Rocker Switch ( Mug-G30 To Mug G75 ) 234 Voltage Selector Switch 235 30A Ammeter Spare For Mr-G Controller 236 Volt Ammeter ( 30A, 300V Ac ) For 3-30 Sec Or 12-20 Sec. 237 Electronic Star -Delta Timer For Mug Starters 238 Electronic Star -Delta Timer Type St100, 160 - 500V, For 3-30 Sec Or 12-20 Sec. 239 Providing And Fitting Of Mu Coil 240 / 360 / 415 V To Mug Submersible Starter 240 Providing And Fitting Of Mu1 / Mu1h / Mu2 / Mu3 Contact Bridge 241 Providing And Fitting Of Mu1 / Mu2 Relay Extension Job To Mug Submersible Starter 242 Providing And Fitting Of Mu1 / M, U1h / Mu2 / Mu3housing To Mug Submersible Starter 243 Providingand Fitting Of New Mug After Removing Old Damaged Ones 244 Mug 6, 6-10 Amp Relay 245 Mug 6, 9-14 Amp Relay 246 Mug 10, 13-21 Amp Relay 247 Mug 10, 20-32 Amp Relay 248 Mug 10, 28-42 Amp Relay 249 Mug 15, 11-18 Amp Relay 250 Mug 15, 13-22 Amp Relay 251 Mug 20, 9-14 Amp Relay 252 Mug 20H, 20-32 Amp Relay 253 Mug 20H, 28-42 Amp Relay 254 Mug 30, 20-33 Amp Relay 255 Mug 30, 30-50 Amp Relay 256 Mug 40, 30-50 Amp Relay 257 Mug 40, 36-60 Amp Relay 258 Mug 50, 36-50 Amp Relay 259 Mug 50, 45-75 Amp Relay 260 Mug 75, 45-75 Amp Relay 261 Mug 75, 66-110 Amp Relay 262 Mccbproviding And Fitting Of 3-Pole 415V Mccb With Thermal Magnetic Release Having 36Ka Breaking Capacity ( Ics= 100% Icu ) ( Make: L&T D-Sine Or Equivalent ) Having Max. Of Thermal Release Range As Under: 263 Upto And Including 100A ( Ics= 50% Icu ) 264 125A 265 160A 266 200A 267 250A 268 400A 269 Providing And Fitting Of 3-Pole 415V Mccb With Thermal Magnetic Release Having 50Ka Breaking Capacity Ics = 100% Icu ( Make: L&T D-Sine Or Equivalent ) Having Max. Of Thermal Release Range As Under: 270 125A 271 160A 272 200A 273 250A 274 400A 275 630A 276 Providing Of Set Of Spreader Terminals For Above 3-Pole Mccbs 277 100A 278 125A 279 250A 280 400A 281 630A 282 Providing And Fitting Of 4-Pole 415V Mccb With Thermal Magnetic Release Having 50Ka Breaking Capacity Ics = 100% Icu ( Make: L&T D-Sine Or Similar ) Having Max. Of Thermal Release Range As Under: 283 125A 284 160A 285 200A 286 250A 287 400A 288 630A 289 Spares For Acb ( L&T C-Power ) Providing And Fitting Of Pole Assembly For Draw Out Type Acb ( L&T C-Power ) 290 Upto 1250A 291 2000A 292 Providing And Fitting Of Arc Chute ( 440V ) For Acb ( L&T C-Power ) 293 Upto 1250A 294 1600 - 2000A 295 Providing And Fitting Of Jaw Contact For Acb ( L&T C-Power ) 296 630-1000A 297 1250A 298 1600A / 2000A 299 Providing And Fitting Of Fixed Arcing Contact For Acb ( L&T C-Power ) 300 800- 1600A 301 2000A 302 Providing And Fitting Of Moving Arcing Contact For Acb ( L&T C-Power ) 303 800- 2000A 304 Providing And Fitting Of Shunt Release For Acb ( L&T C-Power ) 305 Providing And Fitting Of Under Voltage Release For Acb ( L&T C-Power ) 306 Providing And Fitting Of Moving Arcing Contact For Acb ( L&T C-Power ) 307 Providing And Fitting Of Terminal Adaptor For Draw Out L&T C-Power Acb Of Ratings As Under: 308 Upto 800 - 1250A 309 1600 - 2000A 310 Providing And Fitting Of Thermal-Magnetic Release ( Type Dn1 ) For L&T C-Power Acb 311 Providing And Fitting Of Ct For Dn1 Type L&T C-Power Acb 312 800 / 1000A 313 1250 / 1600A 314 2000A 315 Providing And Fitting Of Main Spring For 3-Pole Acb ( L&T C-Power ) 316 800- 1600A 317 2000A 318 Providing Of Racking Handle For Draw-Out Type Acbs ( L&T C-Power ) Rating Upto 2000A 319 Providing And Replacement Of Spring Charging Motor ( Ac / Dc ) 320 Providing And Replacement Of Motor Limit Switch 321 Instrumentation And Panel Accessoriesproviding And Fitting Of 96X96 Flush Mounting 3-Phase Led Ammeter / Voltmeter Of Class 1 Accuracy ( Make: L&T / Schneider / Rishabh / Ae ) 322 Providing And Fitting Of Flush Type Analog Moving Iron Ac Meter As Under: ( Make: Rishabh / Ae / C&S / Bch ) 323 48X48mm 500V Voltmeter 324 96X96mm 500V Voltmeter 325 144X144mm 500V Voltmeter 326 96X96mm Ammeter ( 5A Ct Operated ) 327 Providing And Fitting Of Flush Type Frequency Meter With Range 45-55Hz: ( Make: Rishabh / Ae / L&T / Schneider / Bch ) 328 Providing And Fitting Of 10A Line Current Ammeter Selector Switch With Off ( Make: L&T / Rishabh / Ae / Teknic ) 329 Providing And Fitting Of 10A Voltmeter Selector Switch With Off ( Make: L&T / Rishabh / Ae / Teknic ) 330 Providing And Fitting Of Tape Insulated Ring Type Metering Current Transformers ( Ae / Rishabh / Crompton / Kilburn ) As Under: 331 100 / 5A Or 150 / 5A - Class 1 - Burden 5Va 332 200 / 5A - Class 1 - Burden 10Va 333 400 / 5A - Class 1 - Burden 15Va 334 600 / 5A - Class 1 - Burden 15Va 335 800 / 5A - Class 1 - Burden 15Va 336 1000 / 5A - Class 1 - Burden 15Va 337 2000 / 5A - Class 1 - Burden 15Va 338 Extra For 1A Secondary Upto 600 / 1A Over Corresponding Rate 339 Providing And Fitting Of Analog Vac Hour Meter ( Make: L&T Or Equivalent Make ) 340 Din Mounting Type 341 Flush Mounting Type 342 Providing And Fitting Of Flush Or Projecting Head Push Button With Contact Block ( L&T / Teknic / Abb / Bch / Schneider Or Any Other Reputed Make ) 343 Providing And Fitting Of Led Phase Indicator With Surge Protection ( L&T / Teknic / Abb / Bch / Schneider Or Any Other Reputed Make ) 344 Providing And Fitting 3 Phase, 3 / 4 Wire Adjustable Under & Over Voltage Monitoring Relay ( Minilec Vct D2 Or Equivalent ) 345 Providing, Fitting And Setting Of 415V Auto Reset Single Phase Preventor ( L&T / Minilec / Bch Or Equivalent Make ) 346 50V Or Less Unbalance & 1 C / Odin Mounted 347 50V Or Less Unbalance & 1 C / Opanel Wall Mounted 348 70V Or Less Unbalance & 2 C / Odin Mounted 349 Providing And Fitting Of 32A Dp Switch ( Anchor / Ssk Or Any Other Reputed Make ) 350 Providing Of Hrc Fuses ( 2A - 32A ) Ratings 351 Providing And Fitting Of Fuse Holders For Fuses Upto 32A Rating 352 Providing And Fixing Upvc Panel Trunking With Cover 353 15X15mm 354 25X25mm 355 Terminals / Lugsproviding And Crimping Of Various Aluminium Tube Lugs ( Dowells / Action / Or Any Other Reputed Make ) With Tapping, Insulation As Under: 356 16 Sq. Mm 357 25 Sq. Mm 358 35 Sq. Mm 359 50 Sq. Mm 360 70 Sq. Mm 361 95 Sq. Mm 362 120 Sq. Mm 363 150 Sq. Mm 364 185 Sq. Mm 365 225 Sq. Mm 366 240 Sq. Mm 367 300 Sq. Mm 368 Providing And Crimping Of Various Copper Tube Lugs ( Dowells / Action / Or Any Other Reputed Make ) With Tapping, Insulation As Under: 369 16 Sq. Mm 370 25 Sq. Mm 371 35 Sq. Mm 372 50 Sq. Mm 373 70 Sq. Mm 374 95 Sq. Mm 375 120 Sq. Mm 376 150 Sq. Mm 377 185 Sq. Mm 378 225 Sq. Mm 379 240 Sq. Mm 380 300 Sq. Mm 381 Cablesproviding And Fitting Of Pvc Insulated 1100V Flat 3-Core Industrial Copper Cable For Submersible Pump Motors ( Preferred Makes: Finolex / L&T / Havells / Kei / Polycab ) 382 1.5 Sqmm 383 2.5 Sqmm 384 4.0 Sqmm 385 6.0 Sqmm 386 10.0 Sqmm 387 16.0 Sqmm 388 25.0 Sqmm 389 35.0 Sqmm 390 Providing And Fitting Of Xlpe Insulated, 1100V Single Core Armoured Industrial Copper Cable As Under ( Preferred Make: Finolex / Gloster / Havells / Kei / Polycab ) 391 16.0 Sqmm 392 25 Sqmm 393 35 Sqmm 394 50 Sqmm 395 70 Sqmm 396 95 Sqmm 397 120 Sqmm 398 150 Sqmm 399 185 Sqmm 400 240 Sqmm 401 300 Sqmm 402 400 Sqmm 403 Providing And Fitting Of Xlpe Insulated, 1100V Single Core Industrial Armoured Aluminium Cable As Under ( Preferred Make: Finolex / Gloster / Havells / Kei / Polycab ) 404 16 Sqmm 405 25 Sqmm 406 35 Sqmm 407 50 Sqmm 408 70 Sqmm 409 95 Sqmm 410 120 Sqmm 411 150 Sqmm 412 185 Sqmm 413 240 Sqmm 414 300 Sqmm 415 Providing And Fitting Of Xlpe Insulated, 1100V 3.5-Core Industrial Armoured Aluminium Cable As Per Is 7098 ( Preferred Make: Finolex / Gloster / Havells / Kei / Polycab ) 416 25 Sqmm 417 35 Sqmm 418 50 Sqmm 419 70 Sqmm 420 95 Sqmm 421 120 Sqmm 422 150 Sqmm 423 185 Sqmm 424 240 Sqmm 425 300 Sqmm 426 Wiringproviding And Fitting Of Pvc Insulated 1100V Flexible Copper Cable ( Frls ) For Electrical Installations As Under ( Preferred Makes: Finolex / Anchor / L&T / Havells / Kei / Polycab ) 427 1.0 Sqmm 428 1.5 Sqmm 429 2.5 Sqmm 430 4.0 Sqmm 431 6.0 Sqmm 432 10.0 Sqmm 433 16.0 Sqmm 434 2X1.5 Sqmm 435 2X2.5 Sqmm 436 2X6 Sqmm ( Aluminium Unarmoured ) 437 Conduits 438 Providing And Fixing 25Mm Pvc Round Conduit ( Medium ) With Allied Pvc Fittings 439 Providing And Fixing Upvc Trunking 25X16mm With Allied Fittings 440 Providing And Fixing Polypropylene Corrugated Flexible Conduit 441 25Mm 442 32Mm 443 Providing And Fitting Perforated Ms Cable Trays Including Horizontal And Vertical Bends, Reducers, Tees, Cross Members And Other Accessories As Required And Duly Suspended From The Ceiling With Ms Suspenders Or Fixing On Cantilever Supports And Including Painting Etc As Required. 444 100 X 50 X 1.6Mm 445 150 X 50 X 1.6Mm 446 Electrical Fitingsproviding And Fitting Of Various Electrical Fittings As Under ( Preferred Makes: Anchor / Ssk / Havells ) 447 Switch-6A-Sp-1Way, 240V, 50 Hz, Ac. 448 Switch-6A-Sp-2Way, 240V, 50 Hz, Ac. 449 Cord Switches:- Providing And Fitting Of Cord Switch-6A-Sp-1Way, 240V, 50 Hz, Ac / Hanging Bell Push. 450 Bell Push 240V, 50 Hz, Ac. 451 6A Socket:- Providing And Fitting Of6a-2 / 3 Pin-Universal Socket, 240V, 50 Hz, Ac. 452 Neon Indicator 453 Mini Telephone Jack 454 Fan Regulator ( Mini ) With Rotary Step 455 Fan Regulator ( Deluxe ) With Rotary Step 456 Shuttered-3 Pin Socket And Switch ( Box / Recessed ) - 20A-Sp-1 Way, 230V 50 Hz, Ac. 457 Plug Top 15 / 16A 3 Pin ( Isi Marked ) 458 32A Tp Switch 415V With Neon 459 32A Dp Switch 240V With Neon 460 Surface Mounting Box For Switches As Follows: 461 1 Gang Box 462 2 Gang Box 463 3 Gang Box 464 4 Gang Box 465 5 Gang Box 466 6 Gang Box 467 7 Gang Box 468 4 Gang Box ( Double Domestic ) 469 Providing, Fixing, Testing Of 6A Ceiling Rose 470 Providing And Installation Of Pendant / Angle / Batten Holders 6A 240V 471 Providing And Installation Of Spn Sheet Steel Enclosed Distribution Boxes - Single Door ( Make: L&T / Legrand / Hager / Havells / Benlo ) 472 4 Way 473 8 Way 474 12 Way 475 16 Way 476 Providing And Installation Of ‘B’ Series Mcb 240V, 50Hz, 10Ka Suitable For Lighting And Other Domestic Loads ( Preferred Make: L&T / Legrand / Hager / Havells / Schneider ) 477 6-32A Sp 478 40A Sp 479 6-32A Dp 480 40A Dp 481 100A 4P Isolator 482 Providing And Installation Of Change Over Switches Of Metal Enclosure 240V 50Hz ( Preferred Make: Anchor / Ssk / Havells / L&T ) 483 2-Pole 16A 415V 484 2-Pole 32A 415V 485 4-Pole 32A 415V 486 4-Pole 63A 415V 487 4-Pole 100A 415V 488 Providing And Installation Of Busbar Chamber 3-Ph 4 Bar Heavy Duty Copper Strips With Rating As Under ( Preferred Make: Havells / Ssk / L&T ) 489 63A 415V 490 100A 415V 491 200A 415V 492 Manpower 493 Hiring Charges Of Electrician ( For Troubleshooting / Revamping Of Existing Electrical Fitting, Etc. Exclusive Of Specified Works ) : 494 Hiring Charges Of Labourer For Support Of Electrician 495 Excavating Trenches Of Required Width For Pipes, Cables, Etc In All Kinds Of Soil Including Excavation For Sockets And Dressing Of Sides, Ramming Of Bottoms, Depth Upto 1.5 M, Including Getting Out The Excavated Soil, And Then Returning The Soil As Required, In Layers Not Exceeding 20 Cm In Depth, Including Consolidating Each Deposited Layer By Ramming, Watering, Etc. And Disposing Of Surplus Excavated Soil As Directed, Within A Lead Of 50 M 496 Pipes, Cables Etc, Not Exceeding 80 Mm Dia. 497 Pipes, Cables Etc. Exceeding 80 Mm Dia. But Not Exceeding 300 Mm Dia 498 Pipes, Cables Etc. Exceeding 300 Mm Dia But Not Exceeding 600 Mm Dia 499 Pipes, Cables Etc. Exceeding 600 Mm Dia But Not Exceeding 1200 Mm Dia 500 Extra For Excavating Trenches For Pipes, Cables Etc. In All Kinds Of Soil For Depth Exceeding 1.5 M, But Not Exceeding 3M. ( Rate Is Over Corresponding Basic Item For Depth Upto 1.5 Metre ) . 501 Extra For Excavating Trenches For Pipes, Cables, Etc, In All Kinds Of Soil For Depth Exceeding 3 M In Depth, But Not Exceeding 4.5 M. ( Rate Is Over Corresponding Basic Item For Depth Upto 1.5 Metre. )
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 4
Jammu And Kashmir View Result →
9.
Drinking Water Supply and Sanitation #10284418 Price Bid
Fixing Of Rate Contract For Repairs/ Replacement To Electrical Equipment Installed At Different Wsss Of Phe Mechanical Sub-Division Shopian (District Pulwama And Shopian) For The Financial Year 2023-24- 1 Mechanical transportation, loading, unloading and handling of various items such as pump parts, motors, starters, voltage stabilizers, coil assemblies, welding tools & plant, etc. using appropriate means of transport as under: 2 Private car, auto-rickshaw or similar with 1.0 km lead 3 Extra per kilometer for lead >1.0 kms upto 5.0 kms 4 Extra per kilometer for lead >5.0 kms upto 10.0 kms 5 Extra per kilometer for lead >10.0 kms upto 20.0 kms 6 Extra per kilometer for lead >20.0 kms upto 30.0 kms 7 Load carrier auto, mini van or similar with 1.0 km lead 8 Extra per kilometer for lead >1.0 kms upto 5.0 kms 9 Extra per kilometer for lead >5.0 kms upto 10.0 kms 10 Extra per kilometer for lead >10.0 kms upto 20.0 kms 11 Extra per kilometer for lead >20.0 kms upto 30.0 kms 12 Mini truck like Tata mobile, Bolero Camper or similar with 1.0 km lead 13 Extra per kilometer for lead >1.0 kms upto 5.0 kms 14 Extra per kilometer for lead >5.0 kms upto 10.0 kms 15 Extra per kilometer for lead >10.0 kms upto 20.0 kms 16 Extra per kilometer for lead >20.0 kms upto 30.0 kms 17 VOLTAGE STABILIZERSDismantling of 415V 3-ph Voltage Stabilizer by way of opening of top lid, disassembling of voltage regulator, removing of all incoming and outgoing connections, taking out of damaged copper legs after removal of core, etc. The job includes draining out of T. Oil and its safe placement for further refilling. 18 upto 50 kVA 19 >50 upto 100kVA 20 >100kVA upto 250 kVA 21 Greater than 250 kVA 22 Assembling of all parts of 3-ph Voltage Stabilizer, connecting of leads of all incoming and outgoing connections and refilling of old drained out of T. Oil 23 upto 50 kVA 24 >50 upto 100kVA 25 >100kVA upto 250 kVA 26 Greater than 250 kVA 27 Isolating and disconnecting of all incoming and outgoing leads from autotransformer starter. Draining out transformer oil from the oil tank and collecting in a suitable vessel. Taking out the damaged autotransformer coil assembly from oil tank. 28 >60 upto 200 HP 29 Providing of transformer oil conforming to IS 335 (Preferred make: Power oil/ Indian Oil Servo/ HPCL) 30 Filtration of existing/ reclaimed T-oil at suitable temperature (inclusive of all logistics and charges for filtration plant, etc)(Process loss maximum of 5% allowed) 31 Rewinding burnt/ damaged windings of voltage stabilizer coil assembly (comprising of three limbs) using superior quality copper wire of proper gauge as per requirement with superior insulation. (Note: The unserviceable scrap copper generated shall be property of the firm and is taken into account for estimation of rates). 32 10kVA rating 33 30kVA rating 34 50kVA rating 35 75kVA rating 36 100kVA rating 37 150kVA rating 38 175kVA rating 39 200kVA rating 40 250kVA rating 41 Removing of damagedplate type voltage regulator switch from 3 phase , 415 ±15 % Volt voltage stabilizer and providing and fitting of new plate type voltage regulator switch having copper contact points with 6 steps. the job includes cost on account of skilled/semi-skilled labour required for work 42 10kVA rating 43 30kVA rating 44 50kVA rating 45 75kVA rating 46 100kVA rating 47 150kVA rating 48 175kVA rating 49 200kVA rating 50 250kVA rating 51 Impregnation/heat treatment ofwinding assembly of 3 phase, 415 ±15 % Volt voltage stabilizerby way of keeping it in an electric oven for about 24 hours and at approperate temperature. 52 10kVA rating 53 30kVA rating 54 50kVA rating 55 75kVA rating 56 100kVA rating 57 150kVA rating 58 175kVA rating 59 200kVA rating 60 250kVA rating 61 Removing of damaged copper connection terminal bolt with washer and nut from3 phase, 415 ±15 % Volt voltage stabilizer and providing and fitting of new copper connection terminal bolt with nut and washer. 62 10kVA rating 63 30kVA rating 64 50kVA rating 65 75kVA rating 66 100kVA rating 67 150kVA rating 68 175kVA rating 69 200kVA rating 70 250kVA rating 71 500kVA rating 72 Hiring of portable welding set /soldering equipment etc. excluding power charges 73 Arresting of leakage in, 3 phase , 415 ±15 % Volt voltage stabilizer tank along with radiator fins/tubesby way of soldering/ welding at the cracked spot (average length of spot = 1 inch) 74 Providing and replacement of copper contact points on regulator plate 75 Providing and Fitting of LV copper terminal connectors with allied insulation _ (for finished weight of the connector) 76 STARTERIsolating and disconnecting of all incoming and outgoing leads from autotransformer starter. Draining out transformer oil from the oil tank and collecting in a suitable vessel. Taking out the damaged autotransformer coil assembly from oil tank. 77 upto 60 HP rating 78 >60 upto 200 HP 79 >200 HP upto 350 HP 80 greater than 350 HP 81 Fitting of autotransformer coil assembly in the starter oil tank, filling of t.oil in the tank, connecting all leads and load testing of the starter. 82 upto 60 HP rating 83 >60 upto 200 HP 84 >200 HP upto 350 HP 85 greater than 350 HP 86 CONTACTORSProviding and fitting of 3-pole contactor (AC-3 duty) with specified coil voltage: 87 L&T ML 1.5 88 L&T ML 2 89 L&T ML 3 90 L&T ML 4 91 L&T ML 6 92 L&T ML 12 93 L&T MNX 50 94 L&T MNX 70 95 L&T MNX 80 96 L&T MNX 95 97 L&T MNX 110 98 L&T MNX 140 99 L&T MNX 185 100 L&T MNX 225 101 L&T MNX 250 102 MK1 103 MK2 104 MU1 105 MU1H 106 MU2 107 MU3 108 ML2W 109 ML3W 110 ML4W 111 ML6W 112 Schneider Electric LC1F265 (without coil) 113 Schneider Electric LC1F330 (without coil) 114 Schneider Electric LC1F400 (without coil) 115 Schneider Electric LC1F630 (without coil) 116 32A AC-3 rating (Siemens 3TF/ L&T Type MO/ Schneider) 117 45A AC-3 rating with 2NO + 2NC auxillary contacts (Siemens 3TF/ L&T Type MO/ Schneider) 118 Providing and fitting of new AC coil with specified coil voltage for contactors: 119 9A to 45A AC-3 rating (Siemens 3TF/ equivalent) 120 L&T ML 2/ 3 121 L&T ML 4/ 6 122 L&T ML 10/ 12 123 L&T MNX 50/ 70/ 80 124 L&T MNX 95/ 110/ 140 125 L&T MNX 185/ 225/ 250 126 L&T MNX 300/ 400 127 L&T MNX 550/ 650 128 Schneider Electric LC1F185/ LC1F225 129 Schneider Electric LC1F265/ LC1F330 130 Schneider Electric LC1F400 131 Schneider Electric LC1F630 132 Providing and fitting of new Contact kit set for contactors 133 32A AC-3 rating (Siemens 3TF/equivalent) 134 L&T ML 2 135 L&T ML 3 136 L&T ML 4 137 L&T ML 6 138 L&T ML 10 139 L&T ML 12 140 Providing and fitting of auxillary contactors/ control relay 141 L&T MX0 having 04 contacts (all combinations) for AC control 142 L&T MX0 having 04 contacts (all combinations) for DC control 143 L&T ML (1NO+1NC) side mounting auxillary contact block 144 L&T MNX/MCX front mounting type having 04 contacts (all combinations) 145 TIMING RELAYSProviding, fitting and setting up of single range auto reset synchronous ON delay timer (L&T or equivalent make) 146 Providing, fitting and setting of electropneumatic timing relay with timing range upto 60s; coil voltage 415V AC (BCH or equivalent make) . 147 (2NO + 2NC) double block; ON delay 148 (2NO + 2NC) double block; ON & OFF delay 149 Providing and fitting of spares for electropneumatic timing relay (BCH make or equivalent) 150 (2NO + 2NC) contact block 151 Magnetic coil 415V AC 152 Magnet frame assembly without coil 153 Providing, fitting and setting of DIN mounted electronic Timer (L&T GIC or equivalent make) 154 Star Delta (range from 3s - 120s)240V AC 155 Star Delta (range from 3s - 30s)240 - 415V AC 156 ON delay (0.3s - 30hrs) 240V AC 157 THERMAL OVERLOAD RELAYProviding, fitting and setting of thermal overload relay of specified relay range(Make: L&T MN2) 158 Relay range in between 0.2A to 15A 159 14-23A 160 20-33A 161 24-40A 162 Providing, fitting and setting of thermal overload relay of specified relay range(Make: L&T MN5) 163 20-33A 164 30-50A 165 36-60A 166 45-75A 167 66-110A 168 Providing, fitting and setting of thermal overload relay of specified relay range 169 L&T ML1 (Relay range in between 0.15A to 16A) 170 L&T ML2/3 (Relay ranges in between 9A to 42A) 171 MISCELLANEOUS 172 Providing and fitting of bakelite connection plate minimum 10mm thick as per given size for autotransformer with holes for connection studs drilled at requisite spots 173 Complete servicing of control wiring of ATS including checking, tightening of connections, tapping and insulation as per requirement. 174 Complete replacement of suitable copper control wiring of ATS including cable ties, connections, tapping and insulation as per requirement. 175 OIL IMMERSED STARTER SPARESProviding and replacement of operating coil for oil immersed semi-automatic starter, upto 40HP 176 Providing and fitting of heavy duty contact kit set for semi-automatic/ fully automatic SD oil immersed starters (set of 03 moving and 06 stationary contacts), upto 40 HP 177 Spares for oil immersed manual starters 178 Fixed finger contact 179 Moving tip contact 180 No volt coil 181 Moving drum contact (starters upto 40HP) 182 Moving drum contact (starters > 40HP) 183 Base plate Bakelite/ DMC (starters upto 40HP) 184 Base plate Bakelite/ DMC (starters > 40HP) 185 Steam carrier assembly (starters upto 40HP) 186 Steam carrier assembly (starters > 40HP) 187 Sequence shaft (starters upto 40HP) 188 Sequence shaft (starters > 40HP) 189 Bakelite tube for Sequence shaft (starters upto 40HP) 190 Bakelite tube for Sequence shaft (starters > 40HP) 191 Trip rod assembly (starters upto 40HP) 192 Trip rod assembly (starters > 40HP) 193 Lock lever 194 Cam assembly 195 Oil dashpot assembly 196 Overload coil (set of 03 nos.) upto 20HP 197 Overload coil (set of 03 nos.) 30- 40HP 198 Overload coil (set of 03 nos.) 50- 60HP 199 Overload coil (set of 03 nos.) 70- 80HP 200 Overload coil (set of 03 nos.) 90- 100HP 201 L&T MU-G SUBMERSIBLE PUMP CONTROLLER SPARESVolt-Ammeter 500V, 202 Electronic Star-Delta Timer 3-30s 203 Providing and fitting of Terminal Block 204 60A - 3 way 205 100A - 3 way 206 Single phase preventing relay Sz5 type 207 Single phase preventing relay SDz5 type 208 Providing, fitting and setting of thermal overload relay of specified relay range(Make: L&T) 209 MK1 (all ranges) 210 MU1 (all ranges) 211 MU2 relays of following ranges 212 6 -10 A, 9 - 14A 213 13 - 21A 214 15 - 25A 215 20 - 32A 216 24 - 38A 217 28 - 42A 218 Providing and fitting of standard operating coil for following contactors 219 MK1/ MK2 220 MU1/ MU2/ MU3 221 Providing and fitting of contact bridge without contact of following contactors 222 MK1/ MK2 223 MU1/ MU2/ MU3 224 Providing and fitting of single moving contact of following contactors 225 MK1 226 MK2 227 MU1 228 MU2 229 MU3 230 Indicating lamps 231 Rocker switch 232 Rocker switch (MUG-G6 to MUG G20) 233 Rocker switch (MUG-G30 to MUG G75) 234 Voltage Selector switch 235 30A Ammeter Spare for MR-G Controller 236 Volt Ammeter (30A, 300V AC) for 3-30 sec or 12-20 sec. 237 Electronic star -Delta timer for MUG Starters 238 Electronic star -Delta timer type ST100, 160 - 500V, for 3-30 sec or 12-20 sec. 239 Providing and fitting of MU Coil 240/360/415 V to MUG submersible Starter 240 Providing and fitting of MU1/MU1H/MU2/MU3 contact bridge 241 Providing and fitting of MU1/MU2 Relay extension job to MUG submersible starter 242 Providing and fitting of MU1/M,U1H/MU2/MU3housing To MUG submersible starter 243 Providingand fitting of New MUG after removing old damaged ones 244 MUG 6, 6-10 Amp relay 245 MUG 6, 9-14 Amp relay 246 MUG 10, 13-21 Amp relay 247 MUG 10, 20-32 Amp relay 248 MUG 10, 28-42 Amp relay 249 MUG 15, 11-18 Amp relay 250 MUG 15, 13-22 Amp relay 251 MUG 20, 9-14 Amp relay 252 MUG 20H, 20-32 Amp relay 253 MUG 20H, 28-42 Amp relay 254 MUG 30, 20-33 Amp relay 255 MUG 30, 30-50 Amp relay 256 MUG 40, 30-50 Amp relay 257 MUG 40, 36-60 Amp relay 258 MUG 50,36-50 Amp relay 259 MUG 50, 45-75 Amp relay 260 MUG 75, 45-75 Amp relay 261 MUG 75, 66-110 Amp relay 262 MCCBProviding and fitting of 3-pole 415V MCCB with thermal magnetic release having 36kA breaking capacity (Ics= 100% Icu) (Make: L&T d-sine or equivalent) having max. of thermal release range as under: 263 upto and including 100A (Ics= 50% Icu) 264 125A 265 160A 266 200A 267 250A 268 400A 269 Providing and fitting of 3-pole 415V MCCB with thermal magnetic release having 50kA breaking capacity Ics = 100% Icu (Make: L&T d-sine or equivalent) Having max. of thermal release range as under: 270 125A 271 160A 272 200A 273 250A 274 400A 275 630A 276 Providing of set of spreader terminals for above 3-pole MCCBs 277 100A 278 125A 279 250A 280 400A 281 630A 282 Providing and fitting of 4-pole 415V MCCB with thermal magnetic release having 50kA breaking capacity Ics = 100% Icu (Make: L&T d-sine or similar) Having max. of thermal release range as under: 283 125A 284 160A 285 200A 286 250A 287 400A 288 630A 289 SPARES FOR ACB (L&T C-POWER)Providing and fitting of pole assembly for draw out type ACB (L&T C-power) 290 upto 1250A 291 2000A 292 Providing and fitting of Arc Chute (440V) for ACB (L&T C-power) 293 upto 1250A 294 1600 - 2000A 295 Providing and fitting of Jaw contact for ACB (L&T C-power) 296 630-1000A 297 1250A 298 1600A/ 2000A 299 Providing and fitting of Fixed arcing contact for ACB (L&T C-power) 300 800- 1600A 301 2000A 302 Providing and fitting of Moving arcing contact for ACB (L&T C-power) 303 800- 2000A 304 Providing and fitting of Shunt release for ACB (L&T C-power) 305 Providing and fitting of Under Voltage Release for ACB (L&T C-power) 306 Providing and fitting of Moving arcing contact for ACB (L&T C-power) 307 Providing and fitting of Terminal Adaptor for Draw out L&T C-POWER ACB of ratings as under: 308 upto 800 - 1250A 309 1600 - 2000A 310 Providing and fitting of thermal-Magnetic Release (type DN1) for L&T C-power ACB 311 Providing and fitting of CT for DN1 type L&T C-power ACB 312 800/ 1000A 313 1250/ 1600A 314 2000A 315 Providing and fitting of main spring for 3-pole ACB (L&T C-power) 316 800- 1600A 317 2000A 318 Providing of racking handle for draw-out type ACBs (L&T C-power) rating upto 2000A 319 Providing and replacement of spring charging motor (AC/ DC) 320 Providing and replacement of motor limit switch 321 INSTRUMENTATION AND PANEL ACCESSORIESProviding and fitting of 96x96 flush mounting 3-phase LED ammeter/ voltmeter of Class 1 accuracy (Make: L&T/ Schneider/ Rishabh/ AE) 322 Providing and fitting of flush type analog moving iron AC meter as under:(Make: Rishabh/ AE/ C&S/ BCH) 323 48x48mm 500V voltmeter 324 96x96mm 500V voltmeter 325 144x144mm 500V voltmeter 326 96x96mm ammeter (5A CT operated) 327 Providing and fitting of flush type frequency meter with range 45-55Hz:(Make: Rishabh/ AE/ L&T/ Schneider/ BCH) 328 Providing and fitting of 10A line current ammeter selector switch with OFF (Make: L&T/Rishabh/ AE/ Teknic) 329 Providing and fitting of 10A voltmeter selector switch with OFF(Make: L&T/ Rishabh/ AE/ Teknic) 330 Providing and fitting of tape insulated ring type metering current transformers (AE/ Rishabh/ Crompton/ Kilburn) as under: 331 100/5A or 150/5A - Class 1 - Burden 5VA 332 200/5A - Class 1 - Burden 10VA 333 400/5A - Class 1 - Burden 15VA 334 600/5A - Class 1 - Burden 15VA 335 800/5A - Class 1 - Burden 15VA 336 1000/5A - Class 1 - Burden 15VA 337 2000/5A - Class 1 - Burden 15VA 338 Extra for 1A secondary upto 600/1A over corresponding rate 339 Providing and fitting of analog VAC hour meter(Make: L&T or equivalent make) 340 DIN mounting type 341 Flush mounting type 342 Providing and fitting of flush or projecting head push button with contact block (L&T/ Teknic/ ABB/ BCH/ Schneider or any other reputed make) 343 Providing and fitting of LED phase indicator with surge protection (L&T/ Teknic/ ABB/ BCH/ Schneider or any other reputed make) 344 Providing and fitting 3 Phase, 3/4 Wire adjustable Under & Over Voltage monitoring relay (Minilec VCT D2 or equivalent) 345 Providing, fitting and setting of 415V auto reset single phase preventor (L&T/ Minilec/ BCH or equivalent make) 346 50V or less unbalance & 1 C/ODIN mounted 347 50V or less unbalance & 1 C/OPanel wall mounted 348 70V or less unbalance & 2 C/ODIN mounted 349 Providing and fitting of 32A DP switch (Anchor/ SSK or any other reputed make) 350 Providing of HRC fuses (2A - 32A) ratings 351 Providing and fitting of Fuse holders for fuses upto 32A rating 352 Providing and fixing uPVC panel trunking with cover 353 15x15mm 354 25x25mm 355 TERMINALS/LUGSProviding and crimping of various aluminium tube lugs (Dowells/ Action/ or any other reputed make) with tapping, insulation as under: 356 16 sq. mm 357 25 sq. mm 358 35 sq. mm 359 50 sq. mm 360 70 sq. mm 361 95 sq. mm 362 120 sq. mm 363 150 sq. mm 364 185 sq. mm 365 225 sq. mm 366 240 sq. mm 367 300 sq. mm 368 Providing and crimping of various copper tube lugs (Dowells/ Action/ or any other reputed make) with tapping, insulation as under: 369 16 sq. mm 370 25 sq. mm 371 35 sq. mm 372 50 sq. mm 373 70 sq. mm 374 95 sq. mm 375 120 sq. mm 376 150 sq. mm 377 185 sq. mm 378 225 sq. mm 379 240 sq. mm 380 300 sq. mm 381 CABLESProviding and fitting of PVC insulated 1100V flat 3-core industrial copper cable for submersible pump motors (Preferred makes: Finolex/ L&T/ Havells/ KEI/ Polycab) 382 1.5 sqmm 383 2.5 sqmm 384 4.0 sqmm 385 6.0 sqmm 386 10.0 sqmm 387 16.0 sqmm 388 25.0 sqmm 389 35.0 sqmm 390 Providing and fitting of XLPE insulated, 1100V single core armoured industrial copper cable as under (Preferred make: Finolex/ Gloster/ Havells/ KEI/ Polycab) 391 16.0 sqmm 392 25 sqmm 393 35 sqmm 394 50 sqmm 395 70 sqmm 396 95 sqmm 397 120 sqmm 398 150 sqmm 399 185 sqmm 400 240 sqmm 401 300 sqmm 402 400 sqmm 403 Providing and fitting of XLPE insulated, 1100V single core industrial armoured aluminium cable as under (Preferred make: Finolex/ Gloster/ Havells/ KEI/ Polycab) 404 16 sqmm 405 25 sqmm 406 35 sqmm 407 50 sqmm 408 70 sqmm 409 95 sqmm 410 120 sqmm 411 150 sqmm 412 185 sqmm 413 240 sqmm 414 300 sqmm 415 Providing and fitting of XLPE insulated, 1100V 3.5-core industrial armoured aluminium cable as per IS 7098 (Preferred make: Finolex/ Gloster/ Havells/ KEI/ Polycab) 416 25 sqmm 417 35 sqmm 418 50 sqmm 419 70 sqmm 420 95 sqmm 421 120 sqmm 422 150 sqmm 423 185 sqmm 424 240 sqmm 425 300 sqmm 426 WIRINGProviding and fitting of PVC insulated 1100V flexible copper cable (FRLS) for electrical installations as under (Preferred makes: Finolex/ Anchor/ L&T/ Havells/ KEI/ Polycab) 427 1.0 sqmm 428 1.5 sqmm 429 2.5 sqmm 430 4.0 sqmm 431 6.0 sqmm 432 10.0 sqmm 433 16.0 sqmm 434 2x1.5 sqmm 435 2x2.5 sqmm 436 2x6 sqmm (Aluminium unarmoured) 437 CONDUITS 438 Providing and fixing 25mm PVC round conduit (medium) with allied PVC fittings 439 Providing and fixing uPVC trunking 25x16mm with allied fittings 440 Providing and fixing Polypropylene Corrugated flexible conduit 441 25mm 442 32mm 443 Providing and fitting perforated MS cable trays including horizontal and vertical bends, reducers, tees, cross members and other accessories as required and duly suspended from the ceiling with MS suspenders or fixing on cantilever supports and including painting etc as required. 444 100 x 50 x 1.6mm 445 150 x 50 x 1.6mm 446 ELECTRICAL FITINGSProviding and fitting of various electrical fittings as under(Preferred makes: Anchor/ SSK/ Havells) 447 Switch-6A-SP-1way, 240V, 50 Hz, AC. 448 Switch-6A-SP-2way, 240V, 50 Hz, AC. 449 Cord Switches:- Providing and fitting of cord switch-6A-SP-1way, 240V, 50 Hz, AC/ hanging bell push. 450 Bell push 240V, 50 Hz, AC. 451 6A Socket:- Providing and fitting of6A-2/3 pin-universal socket, 240V, 50 Hz, AC. 452 Neon indicator 453 Mini telephone jack 454 Fan regulator (Mini) with rotary step 455 Fan regulator (Deluxe) with rotary step 456 Shuttered-3 pin socket and switch (box/ recessed) - 20A-SP-1 way, 230V 50 HZ, AC. 457 Plug Top 15/16A 3 Pin (ISI Marked) 458 32A TP switch 415V with neon 459 32A DP switch 240V with neon 460 Surface mounting box for switches as follows: 461 1 Gang box 462 2 Gang box 463 3 Gang box 464 4 Gang box 465 5 Gang box 466 6 Gang box 467 7 Gang box 468 4 Gang box (double domestic) 469 Providing, Fixing, Testing of 6A ceiling rose 470 Providing and installation of Pendant/ angle/ batten holders 6A 240V 471 Providing and installation of SPN sheet steel enclosed Distribution boxes - Single door (Make: L&T/ Legrand/ Hager/ Havells/ Benlo) 472 4 way 473 8 way 474 12 way 475 16 way 476 Providing and installation of ‘B’ Series MCB 240V, 50Hz, 10kA Suitable for lighting and other domestic loads (Preferred Make: L&T/ Legrand/ Hager/ Havells/ Schneider) 477 6-32A SP 478 40A SP 479 6-32A DP 480 40A DP 481 100A 4P isolator 482 Providing and installation of Change over switches of metal enclosure 240v 50Hz (Preferred make: Anchor/ SSK/ Havells/ L&T) 483 2-pole 16A 415V 484 2-pole 32A 415V 485 4-pole 32A 415V 486 4-pole 63A 415V 487 4-pole 100A 415V 488 Providing and installation of Busbar chamber 3-ph 4 bar heavy duty copper strips with rating as under(Preferred make: Havells/ SSK/ L&T) 489 63A 415V 490 100A 415V 491 200A 415V 492 MANPOWER 493 Hiring charges of Electrician (for troubleshooting/ revamping of existing electrical fitting, etc. exclusive of specified works): 494 Hiring charges of Labourer for support of electrician 495 Excavating trenches of required width for pipes, cables, etc in all kinds of soil including excavation for sockets and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m 496 Pipes, cables etc, not exceeding 80 mm dia. 497 Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia 498 Pipes, cables etc. exceeding 300 mm dia but not exceeding 600 mm dia 499 Pipes, cables etc. exceeding 600 mm dia but not exceeding 1200 mm dia 500 Extra for excavating trenches for pipes, cables etc. in all kinds of soil for depth exceeding 1.5 m, but not exceeding 3m. (Rate is over corresponding basic item for depth upto 1.5 metre). 501 Extra for excavating trenches for pipes, cables, etc, in all kinds of soil for depth exceeding 3 m in depth, but not exceeding 4.5 m. (Rate is over corresponding basic item for depth upto 1.5 metre.)
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 6
Jammu And Kashmir View Result →
10.
Defence #9929205 AOC
Tender For Augmentation Of Power Supply At Naval Area Visakhapatnam.; 1 Schedule A Part – I to Schedule A Part – VII:NOTE: Schedule A Part – I to Part –VII are prepriced by MES. Bidders shall insert their Lumpsum amount in Green coloured field under Column - 6 only 2 Lumpsum price worked out by the contractor for BUILDINGS & STRUCTURES,as listed in Schedule A Part – I 3 Lumpsum price worked out by the contractor for SITE CLEARANCE / AREA DEVELOPMENT/EARTH WORK/EXCAVATION,as listed in Schedule A Part – II 4 Lumpsum price worked out by the contractor for INTERNAL ELECTRIFICATION, as listed in Schedule A Part – III 5 Lumpsum price worked out by the contractor for INTERNAL WATER SUPPLY, as listed in Schedule A Part – IV 6 Lumpsum price worked out by the contractor for SEWAGE DISPOSAL,as listed in Schedule A Part – V 7 Lumpsum price worked out by the contractor for EXTERNAL ELECTRIFICATION, as listed in Schedule A Part – VI 8 Lumpsum price worked out by the contractor for LIGHTENING PROTECTION ,as listed in Schedule A Part – VII 9 Schedule A Part - VIII: (Miscellaneous Items) ( Internal Electrification, Internal water supply, External Electrification, Site clearance & Area development, Lightening Protection and AC & Ref) 10 Internal Electrification 11 M&L for Ponit wiring with 1.5 sqmmPVC insulated and unsheathed copper conductorcable multistranded 1100 Volts grade, FRLS, ISI marked drawn through and inculding non metallic PVC rigid concealed conduit and conduit accessories, medium grade, ISI marked, concealed to wall or surface mounted on pillars/columns including provn of box type switchboard consisting of pre fabricated pressed steel terminal box of suitable size made out of 1.2 mm thick sheets,for mounting modular brackets,with and including modular brackets and switch plates as required at site for fixing modular type switches, sockets etc inculding one run of 1.5 sqmm PVC insulated unsheathed copper cable for earth continuity green in colour, connected to earth duly complete all as specified and directed forOne light/ exhaust fan/ fanpoint controlled by one switch :-Note: (a) The PVC conduit shall be concealed and switch boards shall be flush to wall. (b) On columns/ pillars the box type switchboards surface mounted with necessary PVC conduit upto ceiling/nearest junction tapping shall be surface type conduitand quoted rate deemed to be inclusive for the same.(c) The quoted rate inclsuive necessary modules any type as per requirement incl all accessories complete 12 All as per item No. 10 abovebut one light point controlled by two Nos of two way switch complete all as specefied and directed. 13 All as per item No.10 above but One3 pin socket outlet 05 amps socket on independent board with 1.5 sqmm FRLS PVC wire for phase and neutral and one run of 1.5 sqmm copper cable green in colourfor earth continuty conductor complete all as specefied and directed. 14 All as per item No.10 above but One3 pin socket outlet 15 amps socket on independent board with 2.5 sqmm FRLS PVC wire for phase and neutral and one run of 2.5 sqmm copper cable green in colourfor earth continuty conductor complete all as specefied and directed. 15 All as per item No. 10 above but for one geycer/AC point with 4.0 sqmm FRLS PVC wire for phase and neutral and one run of 4 sqmm copper cable green in colourfor earth continuty conductor complete all as specefied and directed. 16 S&Fexhaust fan, steel body AC single Phase. 230 V of size 450mm sweep with, blades, and frame and louvers fixed on wall making opening, fixing and making good the distrubed surfaces etccomplete with and inclussive of making necessary electric connection from ceiling rose to fan through 1 sqmm twin core flexible wire all as spcified and as directed. 17 S&FLED tube light fitting, batten type,poly carbonate body, 20Watt fitting with all accessories, internally prewired and connecting up with with twin core twisted copper conductor cable of suitable size including tube lamp complete all as specified and directed. 18 S&FLED light fitting, batten type,suspended LED aluminium profile lights cool white 36 watt length 1200mm including all connections, hanging strings complete all as specified and directed. 19 S&FLED bay light fitting 70 Watt 230V AC indoor type with thermal management in multiple optics and industrial type and corrosion resistant complete with driver and lamp complete all as specified and directed. 20 S&FLED flood light fitting 210 Watt 230V AC out door type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and directed. 21 S&F LED bldg Security light fitting 35 Watt, 230AC out door type with high pressure die cast aluminium housing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 ptoction complete all accessories including 1.5sqmm weather proof 3 core FRLS grade copper conductor to fitting including 32mm dia medium grade1.5 m long GI pipe for fixing of street lights, bend to shape for fixing on wall/pole withsuitable MS brackets nuts and bolts etccompelte all as specified and as directred. 22 M&L for submain wiring complete with earth wire of PVC insulated multistranded copper conductor FRLS cable, ISI marked with and inclussive of suitable size PVC rigid counduit concealed to wall/roof, and PVC wire of size 2x2.5 sqmm for phase and neutral duly colour coded and 1x2.5 sqmm for earth continuity conductor green in colour complete all as specified and as directed.( for SPN DB to board and submain wiring of building security light)Note :(i) Two run of 2.5 Sqmm + one run of 2.5 Sqmm as a earth wire cable + one run of PVC conduitshall be measured as an one Unit. 23 M&L for submain wiring complete with earth wire of PVC insulated multistranded copper conductor FRLS cable, ISI marked with and inclussive of suitable size PVC rigid counduit concealed to wall/roof, and PVC wire of size 2x4 sqmm for phase and neutral duly colour coded and 1x4 sqmm for earth continuity conductor green in colour complete all as specified and as directed.Note :(i) Two run of 4 Sqmm + one run of 4 Sqmm as a earth wire cable + one run of PVC conduitshall be measured as an one Unit. 24 M&L for submain wiring complete with earth wire of PVC insulated multistranded copper conductor FRLS cable, ISI marked with and inclussive of suitable size PVC rigid counduit concealed to wall/roof, and PVC wire of size 4x10 sqmm for phase and neutral duly colour coded and 1x10 sqmm for earth continuity conductor green in colour complete all as specified and as directed.Note :(i) four run of 10 Sqmm + one run of 10 Sqmm as a earth wire cable + one run of PVC conduitshall be measured as an one Unit. 25 S&F VTPN MCCB DB 4 way 12 outgoing having powder coated sheet steel enclosure fitted with bus bar, DIN channel & neutral link & earth link complete all as specefied and directed. 26 S&F TPN DB 4 way 12 outgoing having powder coated sheet steel enclosure double door fitted with bus bar, DIN channel & neutral link & earth link complete all as specefied and directed. 27 M&L for earthing complete with GI steel plate electrode 600x600x6 mm, burried directly in ground (earth pit not less than 2.25 m deep below ground level)with top edge of the plate not less than 1.5 m below normal groundlevel, connected to GI wire 4 mm dia (upto 7.5M in length from earth plate) by means of bolts, nuts, check nuts and washers of GI all as shown in electrical plate No-3 of SSR Part-I connected to earthing test point all as specified or indicated including excavation and connected earth work in hard/dense soil, PCC 1:3:6 type C-1 as in pit, 20mm dia GI pipelight grade for watering pipe and 32 mm bore GI light grade for earth lead protection pipe connected upto DBs, and suitable CI top cover with handle, funnel, strainer,charcoal, salt and testing on completion all as specified and directed. Note- Rate quoted deemed to be include excavation and earth work in any type of soil with PCC workcomplete all as specefied and directed.Note: GI earth wire upto 7.5 m shall be deemed to be included in the quoted lumpsum and beyond 7.5 m shall be measured and paid separately under relavent item. 28 Internal Water Supply 29 S&F Bib taps two way, cast copper alloy fancy typechromium plated with crutch or butterfly handle, screwed down for size of15 mm inner dia, suitable fo 16 mm outer dia CPVC pipes complete all as specified and as directed. Make:- Jaquar cat No. OPP-15041PM or equivalent 30 SITE CLEARANCE / AREA DEVELOPMENT/EARTH WORK/EXCAVATION 31 M&L for cleaning jungle incl uprooting of rank vegetation, grass, brush wood, trees and saplings of girth upto 30 cm and removal of rubbish upto a distance of 50 m outside the pheiphery of the area cleared all as specified and as directed. 32 External Electrification 33 Supply, Installation, Testing and Commissioning of Copper wound Power transformer step down outdoor type 132/33 KV, capacity16 MVA(suitable for 10/16MVA cooling), ONAN/ONAF, Vector group Star/star (YNyn0) with on load tap changing gear (+) 5% to (-)15% in steps of 1.25% on HV side, with terminal arrangement of HV Outdoor Bushings/LV Bushing and all standard accessories as per IS 2026 and as specified in PS, including first fill of oil complete comprising the following accessories:-a)Conservator Tankb) Pressure Relief Devicec) Buchholz Relay & Oil Surge Relayd) NCT on EHV and HV sidee) Oil Temperature Indicator (OTI)f) Winding Temperature Indicator (WTI)g) Oil Sealingh) Breatherj) Aircell in conservator tankk) Radiators and control valvesl) Each radiator tank shall have its own cooling fans, shut off valves at the top and bottomm) motor operated OLTC shall be n) On load tap changing with RTCC panelo) Marshalling boxp) Thermosphyn filter 34 q) Terminal Connectorsr) Direct solid earthing both HV side and LV sides) Name Plate (Rating, Diagram and Valve Plates)t) Metallic enclosed NGR as per OEMu) NIFPS to be installed by OEMTransformer rating plate shall contain the information as given in IS-2026 (Part-I).Makes: Bharat Bijlee/Crompton Greaves / Schneider / Siemens 35 Note : a) PCC foundation and mounting rails, all civil work, etc and general works which are required as per site/technically required to achieve optimum efficency of the transformer are to be supplied by the contractor for which rate is deemed to be included in the unit rate quoted.b)Size of plinth, PCC, Rail size etc shall be as per OEM recommendation.c) Technical drgs of the transformer alongwith NIFPS submitted by the contractor is required to be approved by the accepting officer before taking procurement action and the Transformer to be inspected by the rep of accepting officer at various stages at Factory premises as per IS before despatch.d) pre-commissioning inspection of Transformer shall be carried out by Senior Electrical Inspector / Electrical Inspector.e) Manufacturer shall possess NABL accredited test lab for electrical testing(Routine test, type test and special test) 36 f)Full Type Test Reports of at least the followings must be submitted: -1. 132/33 kV Power Transformer for same capacity or higher2. Tap Changer3. Buchholz Relay4. Pressure Relief valve5. Oil Surge Relay6. Temperature rise test7. Impulse test 8. Load and No load loss 37 Supply, install, test and commission lightning arrestor single pole made of polymer , heavy duty station class, gapless, zinc oxide type (non linear) fitted with pressure relief device, arc diverting ports, grading/corona rings, discharge counter with ammeter, mounting insulator complete all as specified and as per IS 3070 (Part I) and with following parameters:- Nominal system voltage : 132 KVNormal discharge current rating : 10 KA .Note- The cost of Galvanised Iron lattice structure including foundation (as Per OEM) is deemed to be included in the Quoted rate 38 Supply, Installation, Testing and Commissioning of cable XLPE insulated, armoured, 132 KV grade (E) copper conductor UG cable, laid in trenches/on structures/in cable duct horizontally or in tier formation as per site condition complete all as per IS specifications of size. 1 C x 630 sqmm. The cable shall be of EHV grade single core, armoured stranded compacted circular Copper conductor of cross section 630 sq.mm, core screening by a layer of semiconducting tape followed by a layer of semiconducting compound, cross linked polyethylene (XLPE) dry cured insulation, insulation screening with semiconducting compound extruded directly over the insulation, longitudinal sealing by a layer of non woven tape with water swellable absorbent over insulation screen, followed by radial sealing of corrugated & seamless or seam welded aluminum with asphalt coating & overall PE sheathed & graphite coated/semi conducting layer and conforming to the technical particulars of specification.IS 7098 part 3 shall be followed for manufacturing of cable along with technical specification. Makes: Universal/ KEI /RPG/CCI.Note- Technical details of the cable submitted by the contractor is required to be approved by the accepting officer before taking procurement action and the cable to be inspected by the rep of accepting officer at Factory premises as per IS before despatch. 39 Supply, lay, connect, test and commission multi core copper conductor cables, PVC insulated, LT 1100 volts grade GI strip/wire armoured in ducts/on structuresincluding clamps, terminations on both ends with glands and connecting up to the equipment all as specified and of following sizes:- 40 4 core 1.5 sqmm 41 4 core 2.5 sqmm 42 6 core 2.5 sqmm 43 6 core 4 sqmm 44 Supply and fix GI cable tray perforated on walls/MS angle iron supportsof depth 100mm following widths including bends, coupler plates complete all as specified.Note: Angle iron used for fixing cable trays will be measued and paid separately. 45 200 mm width 46 300 mm width 47 Material and labour for provision of earthmat laid in trenches/ ducts/ walls made of following sizes of GI strips including jointing by means of brazing complete all as specified :- 48 GI 100 x 10 mm 49 GI 75 x 10 mm 50 GI 50 x 6 mm 51 GI 32 x 6 mm 52 Supply and fix earth strip following sizes laid in trench/ floor/ walls including jointing by means of brazing complete all as specified :- 53 100 x 10 mm copper strip 54 50 x 6 mm copper strip 55 32 x 6 mm copper strip 56 Supply, installing, testing and commissioning of CPRI approved LT panel board, cubical indoor type, fabricated out of 2.00 mm thick CRCA sheet with angle iron frame made of 50 x 50 x 6mm at vertical corners & medium channel at base of panel board floor mounted, dust and vermin proof, with busbar 200 Amps suitable for voltage 415 V 3 phase 4 wire weather proof, with separate hinge door for each compartment with locking arrangement, with back door common openable (screwed), groutedin PCC 1:2:4 complete incl painting the steel surfaces with two coats of zinc chromate primer & two coats of epxoy paint suitable for installation in coastal areas and incl of suitable size aluminium busbar (TPN), suitable cable glands, LED Indicating lamps and incl provn of the following:- 57 (i) 4 Pole MCCB 25 KA 100 A - 1 Nos (I/C)(ii) 4 Pole MCCB 63 Amp, 50 Hz, 415 V with rupturing capacity 25 KA - 03 No (iii) 4 Pole MCCB 40 Amp, 50 Hz, 415 V with rupturing capacity 25 KA - 02 No (iv) 4 Pole MCCB 25Amp, 50 Hz, 415 V with rupturing capacity 25 KA - 02 No (v) Digital voltmeter with selector switch - 1 No (vi) Digital ammeter with CTs & selector switch - 1 No (vii) LED indicating lamps - 8 sets (3 lamps/set) 58 Supply and lay in trenches HDPE pipe Double wall corrugated 200 mm dia with integral socketsfor cable protection including necessary collars, earth work and sealing at both ends with bitumen compound complete all as specified. 59 Supply, lay, connect, test and commission cable LT 1100 volts heavy duty XLPE insulated armoured aluminium conductors, in trenches/ ducts on angle iron supports including glanding, crimping and connecting up complete all as specified and of following sizes:- 60 3.5 Core x 95 sqmm 61 4 Core x 25 sqmm 62 Supply, Installation, Testing and Commissioning Earthing complete with Galvanised Iron plate electrode 600x600x6 mm thick buried directly in ground(earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m below normal ground level connected to GI earth strip 32 x 6 mm by means of bolts and nuts checknuts and washers of galvanized iron or steel all as specified and shown in electrical plate no 3 of SSR part I including Charcoal and rock salt with necessary excavation and earth work in any type of soil PCC 1:3:6 type C1 chamber Hinged to CI frame with MS bar 6mm dia 150mm c/c reinforcement, watering funnel with 15 mm dia medium grade for watering and for protection of earth electrode 40 mm dia light grade GI pipe all as specified and directed and tested on completion. 63 Supply, Installation, Testing and Commissioning Earthing complete with copper earth plate electrode 600x600x3 mm thick buried directly in ground(earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m below normal ground level connected to copper earth strip 25 x 3 mm by means of bolts and nuts checknuts and washers of galvanized iron or steel all as specified and shown in electrical plate no 3 of SSR part I including Charcoal and rock salt with necessary excavation and earth work in any type of soil PCC 1:3:6 type C1 chamber Hinged to CI frame with MS bar 6mm dia 150mm c/c reinforcement, watering funnel with 15 mm dia medium grade for watering and for protection of earth electrode 32 mm dia light grade GI pipe all as specified and directed and tested on completion. 64 Boring of holes under road, pavement, hard standing by trenches by trenchless technologyas per site conditions using ultra sound technique and necessary machinery complete all as specified 65 depth of trench varying between 2 to 4 meters 66 depth of trench varying between 4 to 7 meters 67 Supply, Installation, Testing and commissioning ofindoor, metal enclosed corrosion proof aluminium alloy gas insulated switchgear 145 KV 3Phase 50 HZ, 2500 Amps, Three phase encapsulated consisting of2 nos outgoing transformer bay in either side of the existing GIS (Siemens) including installation tools, spares, refill kits all as specified. Makes: ABB/CG/GE/SIEMENS 68 Each Transformer feeder bay consists of the following: 2Nosa) Circuit breaker SF6 insulated 145 KV 2500 A 3 pole with short circuit current with stand capacity of 40 KA for 3 sec - 1 No.b) Disconnector cum earthing switch SF6 insulated, 145 KV 2500 A 3 pole motor operated - 2 sets.1 set on Bus side and 1 set on line side.c) Fast acting earth switch SF6 insulated 145 KV motor operated - 1 sets. d) Current transformer 145 KV 300-150/5+5+5 with Core 1:class 0.2, 15 VA , Core 2 : 5P20, Core 3 : PS class, 15 VA respectively - 1 Set (Three Nos).e) Three phase Voltage transformer 0.2 class accuracy, 10 VA burden,145 KV, 132 KV/√3/110V/√3 - 1 set.f) Lightning arrestor gapless type metal zinc oxide type 120 KV rms 10 KA including discharge counter and leakage current meter.g) Bus bars 145 KV 2500 Amps 3Ø - required as per scheme.h) Cable end box suitable for 132 KV system - 1 No.j) Local control panel- 1 No. 69 Note : The GIS system offered by the bidder shall be designed, manufactured, assembled and tested in accordance with the IEC 62271-203 for switch gear and other relevant IEC andfor balance materials as mentioned in PS. The GIS Outgoing bays are to be installed with the existing GIS extension (Siemens Make ) interface in either sides of the setup. Bidder has to supply the following items along with GIS system and costis deemed to be included in GIS system. Civil foundation / mounting rails, all civil work, etc and general works which if required as per site/technically required to achieve optimum efficency are to be supplied by the contractor for which rate is deemed to be included in the unit rate quoted. Erection & commissioing shall be under OEM recommendation and supervision. The earth connection from GIS euipment to earth grid/matt as per OEM recomendation and the cost of same is deemed to be included in the unit price. Technical drgs of the GIS module submitted by the contractor is required to be approved by the accepting officer before taking procurement action and the GIS module to be inspected by the rep of accepting officer at Factory premises as per IS before despatch. Pre-commissioning inspection of GIS module shall be carried out by Senior Electrical Inspector / Electrical Inspector. 70 a) Local control cubicles.b) Gas handling equipment for draining and refilling of each compartment of GIS including filtration and purification equipment and vacuum pump. c) SF6 gas sufficient for first filling of entire switch gear including usual losses during commissioning.d)1 Bottles (40 Kg each) of SF6 gas in non returnable vessels. e)Gas leakage detectors.f) Gas Purity Tester for air content and moisture content in SF6 gas. g)Special tool and tackles for erection operation and maintenance of GIS h)Mandatory spares and tools ( Aux contact ( for CB, Busbar disconnector), Motor for CB drive (DS-ES drive), Bursting Disc, Adsorber, Density Monitor for CB, Tripping coil, Closing Coil. - 01 set Each.(i) Bay control unit. 71 Supply, Installation, Testing and Commissioning of control and relay simplex type panel with front swing & front perplex glass door RAL7035 natural IP 32 ventilation for 132/33 KV transformers protection consisting of the following: 72 a) Numerical Transformer Differential Protection Relay Make- ABB/Siemens – 1nob) Numerical Backup Protection Relay of Make - ABB/Siemens – 1noc) Tri Vector Meter - Secure make Premier 300 or Equivalent- with ABT & RS485 (modbus) port, RJ 45 port Accuracy class 0.2S- 2nod) Auxiliary Relay - with self-reset contacts. Operating time<20ms. (4 Contacts) of Make ABB/Siemens – 5nose) DC/ACSupply Supervision-200ms 73 Supply, Installation, Testing and Commissioning of 145KV 630A 40KAOil filled outdoor termination with composite insulator, solid rod connector bolt and support insulators for cables with XLPE insulation. The termination base plate and the cables metallic sheath shall be electrically insulated from the supporting structure by means of self-supporting stand-off insulators or any other self-supporting means designed to withstand both mechanical and electrical stresses in services. The stress cone shall inhibit possible mechanical stress and deformation of the cable insulation surface during operation and also shall be capable of accommodating minor radial and longitudinal movement without determent to the dielectric stress in the insulation shield. The termination shall be within polymeric or porcelain hollow insulator in brown or grey colour as perstandard practice of manufacturing in addition upon, arcing horn and shield ring shall have to be supplied wherever required. The termination shall be filled with an insulating compound up to a level where the electric field is substantially reduced and shall be offered. Oil filled termination should have silicon oil as di-electric medium. Silicon oil should not be subject to any heating at site prior to filling. The outdoor terminal should be suitable for very heavily polluted atmospheric conditions with total creepage distance of 31 mm/ kV and protected creepage distance of not more than 50% of the total Creepage distance. The cable end terminals for terminating the cables shall be fully compatible with the cables to be supplied. Civil foundation / Supporting Strcuture etc and general works which are required as per site/technically required to achieve optimum efficency are to be supplied by the contractor for which rate is deemed to be included in the unit rate quoted. 74 Supply, Installation, Testing and Commissioning of 145kV Dry type GIS termination suitable for XLPE 132 KV IC x 630 sqmm including necessary accessories , fixtures and fittings of complete installation etc complete all a specified and directed.Indoor Termination at GIS SF6 Housing It shall be dry type without insulating oil. There shall be mechanical devices to maintain the interface pressure if requires. It shall be based on the EPR (Ethylene-Propylene Rubber)- based or silicon based stress relief cone. Termination shall be dry type without insulating oil. Stress relief cone and mechanical devices shall be designed to fit with controlled interference over the cable insulation and shall follow the cables diameter variations still guaranteeing under any service condition a sufficient positive pressure to control the electric field concentration. Plug-in type leading conductors shall be supplied though at the time of detailed engineering confirmation shall be given for selection of normal type, blind type or plug-in type. Design and scope of delivery shall be fully complying with IEC-60859, IEC-62271-209 and possibly adjusted the various needs of project. The main insulation components shall be fully examined and tested in the factory.For cable Termination purpose only certified (certification from cable accessories manufacturer ) personnel shall be employed. Make: Raychem or Equivalent 75 Supply, Installation, testing & commissioning ofHT 33KV VCB line up of Six panels switchboard consisting of 1250A, VCB 33 KV - 2Nos as incomer with Bus coupler cum Bus Riser 1250A VCB 33 KV-1 No with 1250A VCB 33 KV- 3Nos as outgoing.VCB panel indoortype totally enclosed, free standing floor mounting type, compartment based with truck mounted vacuum circuit breaker spring operated electrically and manually charged operating mechanism suitable for horizontalisolation, horizontal draw out type VCBs with copper bus bars, Self supported Insulated Busbar with full voltage rated should be used. Complete VCB panel confirming to IEC 62271-200 standards and IP 4X class of protection comprising necessary bus-bars extension and connections and following protective and control devices as specified below. Circuit Breaker shall be suitable for E2, M2 & C2 duty. Vacuum Interrupters of the circuit breakers shall be completely encapsulated in epoxy housing. The manufacturer of circuit breaker & Panel shall also be the manufacturer of the Vacuum Interrupter, Relay. The switchgear and control gear panels shall be of the fully arc proof for 25 kA for 1Sec AFLR complete all as specified and as directed.Make: ABB /CG / Schneider / Siemens. 76 A. INCOMER-2 Nos ( Each consisting of )33kVIndoorSwitchgear Panel consisting of Breaker-1250A, 25kA draw out type having following accessories :-a. 230VAC Spring Charge Motor.b.110VDC Closing Coil.c.110VDC Shunt Trip Coil.d. Current Transformer Indoor Single Phase Resin Cast Ratio: 400-200/5+5+5 A Core-1: 15VA Class 0.5, Core -2 5P20, Core -3: Class PS - 3nos.e. Potential Transformer Draw out TypeResin cast Ratio : 33KV/√3/110V/√350VA, CLASS: 0.5-3 Nos.f.12 Window Annunciatorg.Digital Ammeter with ASS.h.Digital Voltmeter with VSS.i.Multifunction Load Manager Class 0.5 with RS485 & Ethernet communication.j.Master Trip Relay, TCS Relay , TNC Lockable Type, Manual/Remote Selector Swithc etc.,k. Numerical Protection IEC 61850 Draw out Relay with Graphical display- 1nowith Three Phase O/C & E/F (50, 51, 50N, 51N, 50G, 51G),Three Phase Directional O/C & E/F (67/67N), Negative Phase Sequence O/C (46) ,Inrush Detection (68), Circuit Breaker Failure Protection (50BF), Broken Conductor (46BC), Three Phase O/V, U/V & NDR (27, 59, 59N) ,Thermal Overload (49),Negative Sequence Overvoltage (47) ,Reverse Power (32),Over Frequency (81O), Under Frequency (81U), CT Supervision (60 CTS) ,VT Fuse Failure (60 VTS), 87C (differential P) and 64 (Restricted earth fault) .Relay shall have 8 DI and 8 DO. Makes: ABB/CG/Schneider/Siemens. 77 B. OUTGOING - 3 Nos ( Each consisting of )33kVIndoorSwitchgear Panel consisting of Breaker-1250A, 25kA draw out type having following accessories for Transformer Outgoing.a. 230VAC Spring Charge Motorb.110VDC Closing Coil.c.110VDC Shunt Trip Coil.d. Current Transformer Indoor Single Phase Resin Cast Ratio: 400-200/5+5A Core-1: 15VA Class 0.5, Core -2 5P20, Core-3 : PS class- 3 nos.e.12 Window Annunciator.f.Digital Ammeter with ASS.g. Digital Voltmeter with VSS.h. Multifunction Load Manager Class 0.5 with RS485 & Ethernet communication i. Master Trip Relay, TCS Relay , TNC Lockable Type, Manual/Remote Selector Swithc etc.,j. Numerical Protection IEC 61850 Draw out Relay with Graphical display- 1nowith Three Phase O/C & E/F (50, 51, 50N, 51N, 50G, 51G),Three Phase Directional O/C & E/F (67/67N), Negative Phase Sequence O/C (46) ,Inrush Detection (68), Circuit Breaker Failure Protection (50BF), Broken Conductor (46BC), Three Phase O/V, U/V & NDR (27, 59, 59N) ,Thermal Overload (49),Negative Sequence Overvoltage (47) ,Reverse Power (32),Over Frequency (81O), Under Frequency (81U), CT Supervision (60 CTS) ,VT Fuse Failure (60 VTS), 64 (Restricted earth fault).Relay shall have 8 DI and 8 DO. Makes: ABB/CG/Schneider/Siemens. 78 C. BUS COUPLER- 1 Nos ( Each consisting of )33kVIndoorSwitchgear Panel consisting of Breaker-1250A, 25kA draw out type having following accessories for Transformer Outgoing.a. 230VAC Spring Charge Motor.b.110VDC Closing Coil.c.110VDC Shunt Trip Coil.d. Master Trip Relay, TCS Relay , TNC Lockable Type, Manual/Remote Selector Swithc etc.,e. Electrical & Mechanical Interlocking.f. Numerical Protection Relay with all protection.g. ABT scheme with Manual Option.Note:The above said panelsEarthing truck -01 nos. Earthing truck shall be so designed that it is impossible to earth alive. It shall be provided with capacitive voltage detection with audio visual annunciation. Technical drgs of the VCB panel submitted by the contractor is required to be approved by the accepting officer before taking procurement action and the VCB panel to be inspected by the rep of accepting officer at Factory premises as per IS before despatch. Pre-commissioning inspection of VCB panel shall be carried out by Senior Electrical Inspector / Electrical Inspector. The VCB panel should be GSM based SCADA compatible. 79 Supply, Installation, Testing and Commissioning of Three Phase 4Wire 110V/50A FCBC Thristor based with in-built DCDB and RS485 communicationsuitable for 110V/200AH VRLA battery with 55 Cellsin complete as specified and directed. Make: Amararaja/Exide 80 Supply, installation, testing and commissioning of cable 3 Core 300 Sq.mm 33KV(E) XLPE cable grade cable of size suitable for earthed system having compacted circular stranded aluminium conductor shielded with semi-conducting compound extruded layer XLPE insulated dry cured core shielded with semi-conducting compound extruded layer followed by metallic copper foil, screened inner sheath of extruded PVC, galvanized single flat steel strip armoured and PVC sheathed overall conforming to IS: 7098/Part-II/1985, as amended upto date with ISI marked of following sizes in VCV manufacturing process.Note- Technical details of the cable submitted by the contractor is required to be approved by the accepting officer before taking procurement action and the cable to be inspected by the rep of accepting officer at Factory premises as per IS before despatch 81 S&F of Cable jointing kit for 33 KV grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 300 Sqmm 3 core complete all as specified and directed. 82 S&F of Cable jointing kit for3 Core 300 Sq.mm 33 KV grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable complete all as specified and directed. 83 S&F of Cable jointing kit for 3 Core 300 Sq.mm 33 KV grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable complete all as specified and directed. 84 Supply, laying & testing of 11KV(E)XLPE insulated cable of following sizes suitable for earthed system having compacted circular stranded aluminium conductor shielded with semi-conducting compound extruded layer XLPE insulated dry cured core shielded with semi-conducting compound extruded layer followed by metallic copper foil, screened inner sheath of extruded PVC, galvanized single flat steel strip armoured and PVC sheathed overall conforming to IS: 7098/Part-II/1985, asamended upto date with ISI marked of following sizes in VCV manufacturing process. 85 3 Core 240 Sq.mm 86 3 Core 400 Sq.mm 87 Supply, laying & testing of 11KV(E)XLPE insulated cable of following sizes suitable for earthed system having compacted circular stranded copper conductor 1 core 1000 sqmm shielded with semi-conducting compound extruded layer XLPE insulated dry cured core shielded with semi-conducting compound extruded layer followed by metallic copper foil, screened inner sheath of extruded PVC, galvanized single flat steel strip armoured and PVC sheathed overall conforming to IS: 7098/Part-II/1985, asamended upto date with ISI marked of VCV manufacturing process. 88 S&F for Cable jointing kit for 11 KV grade cable for Outdoor End termination kit heat shrink type joint complete with jointing material and accessories suitable for 1 core 1000 sqmm XLPE armoured copper conductor cable sqmm etc complete all as specified and directed. 89 S&F for Cable jointing kit for 11 KV grade cable for Indoor End termination kit heat shrink type joint complete with jointing material and accessories suitable for 1 core 1000 sqmm XLPE armoured copper conductor cable sqmm etc complete all as specified and directed. 90 S&F for Cable jointing kit for 11 KV grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 240 sqmm etc complete all as specified and directed. 91 S&F of Cable jointing kit for 11 KV grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of following sizes etc. complete all as specified and directed. 92 3 Core 240 Sq.mm 93 3 Core 400 Sq.mm 94 Design, Supply, Installation, Testing and Commissioning of GSM based energy management system/ substation automation system with suitable software capable of taking care of complete data monitoring, data logging and control functions at 132 MRS consisting of 2 Nos 132 KV GIS, 6 Nos HT 33 KV VCBs at MRS , 7 Nos 33 KV VCBs at NSB Substation, 8 Nos 11 KV VCBs at NSB and other allied switchgears at 33/11 KV substation at DH complete with servers, work stations, desk top computers, operating system, communication products and object softwares assembled from industry standard products all as specified 95 a) BCU suitable for substation automation.b) Integration with Existing Scada server.c) Fibre/Eithernet switch (for station level & bay level) -8 sets.d) RTU (with redundant RTU , Power Supply & Hot Swappable IO configuration) - 2 set.e) SCADA software.f) Suitable Modems & ALUs.h) Integration with Existing central SCADA software- 1 set.Note- a) The SCADA system is GSM based and to be integrated with existing SCADA server. b) The cost of Connecting cable (e.g-Optical fibre cable Network, CAT 6 cable Armoured/unarmoured etc) and accessories for integration of IED, Ethernet and RTU, ALU, IED (Relay) as required at site is deemed to be included in the unit price. c) Technical drgs of the SCADA submitted by the contractor is required to be approved by the accepting officer before taking procurement action . 96 Supply and fixing in position Retardant/ extinguishing electric insulated synthetic mat2.5 mm (+/-) 10% thick conforming to BIS -DOC No ET-02 (540) dt 30/04/2004, meeting requirements of IS- 3043, IS-5216 (Part-1, 2 & 3), IS-15652:2006 and IEC 479 Pub-I tested having minimum width of 1000 mm (+/-) 20 mm. All allied materials such as PU-Resin Chemical bond (hardener), special PVC adhesive liquid primer and qty required to complete the job as per site requirement suitable for all voltages not exceeding 33/11 KV system complete all as specified. 97 M&L for RCC cable route indicator semi-circular shape on top of size 600x450x100 mm casted in PCC 1:3:6with TMT bar of size 10 mm dia and foundation base casted in RCC 1:2:4, grouted in earth upto 550 mm duly engraved the following letters HT UG CABLEwith two coats of antifungal weather coat paint, etc all as specified and directed. 98 S & F for Display chart (set of 2 nos) of size 6 x 4 duly made on white polyvinyl sheet exactly showing the locations of the yard and the machineries and equipments installed in the sub-station duly marked properly with legends etc, and a separate chart showing the details of machineries installed with nos, capacity/ rating and make with computer cutting letters of approved size on poly vinyl sheet all as specified and directed. 99 S&F for Display chart (set of 2 nos) of size 4 x 5 duly made on white polyvinyl sheet exactly showing the lay out of transmission and distribution of HT UG cable routes, locations of the HT Joints, drawn on autocad, etc duly marked properly with legends, with computer cutting letters of approved size on poly vinyl sheet, all as specified and directed. 100 S & F for shock treatment chartof size 1.5 m x 1.5 m x 0.025 m duly laminated with wooden frame (tick wood)enclosure all as specified and fixed in position as directed by Engineer-in-charge. 101 S & F First aid GI box containing prescribed medicines for first aid box as per standard quality and quantity each as required to provide first aid treatment in an emergency complete all as specified 102 Supply, Installation, Testing and Commissioning of Power transformer step down outdoor type 33/11 KV, capacity 16 MVA (suitable for 10/16MVA cooling), ONAN/ONAF, Vector group Delta/star (Dyn11) with on load tap changing gear (+) 5% to (-)15% in steps of 1.25% on HV side, with HV/LV Cable Box and all standard accessories as per IS 2026 and as specified in PS, including first fill of oil complete comprising the following accessories:-a)Conservator Tankb) Pressure Relief Devicec) Buchholz Relayd) Oil Surge Relaye) Oil Temperature Indicator (OTI)f) Winding Temperature Indicator (WTI)g) Oil Preservation Equipment likeh) Oil Sealingj) Breatherk) Aircell in conservator tankl) Radiators and control valvesm) Each radiator tank shall have its own cooling fans, shut off valves at the top and bottomn) motor operated OLTC shall be o) On load tap changing with RTCC panelp) Marshalling boxq) Thermosphyn filterr) NIFPS to be installed By OEM 103 Note- i) Technical drgs of the Transformer alongwith NIFPS submitted by the contractor is required to be approved by the accepting officer before taking procurement action and the Transformer to be inspected by the rep of accepting officer at various stages at Factory premises as per IS before despatch. Pre-commissioning inspection of Transformer shall be carried out by Senior Electrical Inspector / Electrical Inspector.ii) The rate quoted is deemed to include the cost of PCC / Brick Masonry Foundation / Platform of transformer as per OEM recommendations and finishing the top surface even and smooth.iii) Manufacturer shall possess NABL accredited test lab for electrical testing(Routine test, type test and special test.iv) Type test reports of33/11 KV Transformer of same capacity or higher Such as Temperature rise, Impulse test, Short circuit test , Vacuum Tests of Tank & Radiator, No Load & Load Loss test and tap changer to be submitted by the bidder during Drawing approval 104 Supplying, Installing, Connecting, Commissioning and Testing of Transformer, Step Down, Outdoor Type, Floor or Platform Mounted complete with standard fittings, 33 KV / 433 V [at No load], AC, 3 Phase, 50 Hz, of 100 KVA capacity, Double Copper Wound, K class Natural Ester Oil immersed, CRGO Core type Naturally cooled, Built-up with class A insulation, having Primary Voltage [HT] 33 KV and Secondary Voltage [LT] of 433 Volts, Delta connected on 33 KV Side & Star connected on 433 Volts side, designed & constructed with particular reference to Tropical Condition, conforming to IS – 1180-2014, including PCC / Brick Masonry Foundation / Platform as per IE Rules, fixing HT / LT Busbar and Cables etc. complete all as specified and as directed andcomprising of the following Specification and Fittings:Continuous Rating: 100 KVANo-Load Voltage Ratio : 33 KV / 433 V Tapping on HV[%]: ± 7.5, ± 5, ± 2.5Phase & Frequency : 3 Phase & 50 HzConnection: Delta StarVector Group : DYN 11Cooling : KNANType: OutdoorNote: The rate quoted is deemed to include the cost of PCC / Brick Masonry Foundation / Platform as per OEM recommendations and finishing the top surface even and smooth complete all as per manufacturer’s recommendations, as specified and as directed. 105 Fittings:[a] Externally hand operated Off–Circuit Tap Switch with position indicator and locking device.[b] Conservator with Oil Gauge, filling hole with plug & drain hole with plug[c] Undercarriage with four plain rollers[d] Oil filling hole cum air release plug[e] Drain Valve cum Sampling Valve[f] Top Filter Valve with Plug[g] Rating Plate with Diagram Plate[h] Lifting lugs for Transformer[j] Lifting lugs for Core[k] Earthing Terminals[l] Thermometer Pockets[m] Silica Gel Breather[n] Explosion Vent[o] Marshalling Box with Double Window[p] OCTC.Note- Technical drgs of the Transformer submitted by the contractor is required to be approved by the accepting officer before taking procurement action and the Transformer to be inspected by the rep of accepting officer at Factory premises as per IS before despatch. Pre-commissioning inspection of Transformer shall be carried out by Senior Electrical Inspector / Electrical Inspector. 106 Supply, Installation, testing & commissioning ofHT 33KV VCB line up Seven panels switchboard consisting of 1250A, VCB 33 KV - 2Nos as incomer with Bus coupler cum Bus Riser 1250A VCB 33 KV-1 No with 1250A VCB 33 KV- 4Nos as outgoing.VCB panel indoortype totally enclosed, free standing floor mounting type, compartment based with truck mounted vacuum circuit breaker spring operated electrically and manually charged operating mechanism suitable for horizontalisolation, horizontal draw out type VCBs with copper bus bars, Self supported Insulated Busbar with full voltage rated should be used. Complete VCB panel confirming to IEC 62271-200 standards and IP 4X class of protection comprising necessary bus-bars extension and connections and following protective and control devices as specified below. Circuit Breaker shall be suitable for E2, M2 & C2 duty. Vacuum Interrupters of the circuit breakers shall be completely encapsulated in epoxy housing. The manufacturer of circuit breaker & Panel shall also be the manufacturer of the Vacuum Interrupter, Relay. The switchgear and control gear panels shall be of the fully arc proof for 25 kA for 1Sec AFLR complete all as specified and as directed.Make: ABB /CG / Schneider / Siemens. 107 A INCOMER-2 Nos ( Each consisting of )33kVIndoorSwitchgear Panel consisting of Breaker-1250A, 25kA draw out type having following accessories .a. 230VAC Spring Charge Motor.b.110VDC Closing Coil.c.110VDC Shunt Trip Coil.d. Current Transformer Indoor Single Phase Resin Cast Ratio: 400-200/5+5 Core-1: 15VA Class 0.5, Core -2 5P20 - 3nos.e. Potential Transformer Draw out Type Resin cast Ratio : 33KV/√3/110V/√3100VA, CLASS: 0.5-3 Nos.f.12 Window Annunciator.g.Digital Ammeter with ASS.h.Digital Voltmeter with VSS.i.Multifunction Load Manager Class 0.5 with RS485 & Ethernet communication.j.Master Trip Relay, TCS Relay , TNC Lockable Type, Manual/Remote Selector Swithc etc.,k. Numerical Protection IEC 61850 Draw out Relay with Graphical display- 1nowith Three Phase O/C & E/F (50, 51, 50N, 51N, 50G, 51G),Three Phase Directional O/C & E/F (67/67N), Negative Phase Sequence O/C (46) ,Inrush Detection (68), Circuit Breaker Failure Protection (50BF), Broken Conductor (46BC), Three Phase O/V, U/V & NDR (27, 59, 59N) ,Thermal Overload (49),Negative Sequence Overvoltage (47) ,Reverse Power (32),Over Frequency (81O), Under Frequency (81U), CT Supervision (60 CTS) ,VT Fuse Failure (60 VTS) and 64 (Restricted earth fault) Relay shall have 8 DI and 8 DO. Makes: ABB/CG/Schneider/Siemens. 108 B. OUTGOING - 4 Nos ( Each consisting of )33kVIndoorSwitchgear Panel consisting of Breaker-1250A, 25kA draw out type having following accessories for Transformer Outgoing.a. 230VAC Spring Charge Motor.b.110VDC Closing Coil.c.110VDC Shunt Trip Coil.d. Current Transformer Indoor Single Phase Resin Cast Ratio: 400-200/5+5+5A Core-1: 15VA Class 0.5, Core -2 5P20, Core -3: Class PS - 3nos.e.12 Window Annunciator.f.Digital Ammeter with ASS.g. Digital Voltmeter with VSS.h. Multifunction Load Manager Class 0.5 with RS485 & Ethernet communication.i. Master Trip Relay, TCS Relay , TNC Lockable Type, Manual/Remote Selector Swithc etc.,j. Numerical Protection IEC 61850 Draw out Relay with Graphical display- 1nowith Three Phase O/C & E/F (50, 51, 50N, 51N, 50G, 51G),Three Phase Directional O/C & E/F (67/67N), Negative Phase Sequence O/C (46) ,Inrush Detection (68), Circuit Breaker Failure Protection (50BF), Broken Conductor (46BC), Three Phase O/V, U/V & NDR (27, 59, 59N) ,Thermal Overload (49),Negative Sequence Overvoltage (47) ,Reverse Power (32),Over Frequency (81O), Under Frequency (81U), CT Supervision (60 CTS) ,VT Fuse Failure (60 VTS),Transformer Differential Protecton (except Stn Transformer )64 (Restricted earth fault) Relay shall have 8 DI and 8 DO. Makes: ABB/CG/Schneider/Siemens. 109 C. BUSCOUPLER- 1 Nos ( Each consisting of )33kVIndoorSwitchgear Panel consisting of Breaker-1250A, 25kA draw out type having following accessories for Transformer Outgoing.a. 230VAC Spring Charge Motor.b.110VDC Closing Coil.c.110VDC Shunt Trip Coil.d. Master Trip Relay, TCS Relay , TNC Lockable Type, Manual/Remote Selector Swithc etc.,e. Electrical & Mechanical Interlocking.f. Numerical Protection Relay.g. ABT scheme with Manual Option.Note:The above said panelsEarthing truck -01 nos. Separate earthing truckfor bus earthing & cable earthing. Earthing truck shall be so designed that it is impossible to earth alive. It shall be provided with capacitive voltage detection with audio visual annunciation.Technical drgs of the VCB panel submitted by the contractor is required to be approved by the accepting officer before taking procurement action and the VCB panel to be inspected by the rep of accepting officer at Factory premises as per IS before despatch. Pre-commissioning inspection of VCB panel shall be carried out by Senior Electrical Inspector / Electrical Inspector. The VCB panel should be GSM based SCADA compatible. 110 Supply, Installation, testing & commissioning ofHT 11KV, 25 kA, VCB line of Nine panels switchboard consisting of 1250 Amps, VCB 11 KV - 02 Nos as Incomer, Bus coupler 1250Amps VCB 11 KV -1Nos , Outoing 1250AVCB 11 KV- 6 Nos.VCB panel indoortype totally enclosed, free standing floor mounting type, compartment based with truck mounted vacuum circuit breaker spring operated electrically and manually charged operating mechanism suitable for horizontalisolation, horizontal draw out type VCBs with copper bus bars, Self supported Insulated Busbar with full voltage rated should be used. The switchgear panel shall be of sheet steel constructionnot less than 2.5mm thickness for load bearing section and not less than 2 mm thickness for non-load bearing and shall totally dust and vermin proof. Complete VCB panel confirming to IEC 62271-200 standards and IP 4X class of protection comprising necessary bus-bars extension and connections and following protective and control devices as specified below. Circuit Breaker shall be suitable for E2, M2, C2duty. The manufacturer of circuit breaker & Panel shall also be the manufacturer of the Vacuum Interrupter, Relay. The switchgear and control gear panels shall be of the fully arc proof for 25 kA for 1Sec AFLR complete Make: ABB /CG / Schneider / Siemens. 111 A. INCOMER-2 Nos ( Each consisting of )11kVIndoorSwitchgear Panel consisting of Breaker-1250A, 25kA draw out type having following accessories:-a. 230VAC Spring Charge Motor.b.110VDC Closing Coil.c.110VDC Shunt Trip Coil.d. Current Transformer Indoor Single Phase Resin Cast Ratio: 800-600-400/5+5+5A Core-1: 15VA Class 0.5, Core -2 5P20, Core -3: Class PS - 3nos.e. Potential Transformer Draw out Type Resin cast Ratio : 11KV/√3/110V/√3100VA, CLASS: 0.5-3 Nos.f.12 Window Annunciator.g.Digital Ammeter with ASS.h.Digital Voltmeter with VSS.i.Multifunction Load Manager Class 0.5 with RS485 & Ethernet communication.j.Master Trip Relay, TCS Relay , TNC Lockable Type, Manual/Remote Selector Swithc etc.,l. Numerical Protection IEC 61850 Draw out Relay with Graphical display- 1nowith Three Phase O/C & E/F (50, 51, 50N, 51N, 50G, 51G),Three Phase Directional O/C & E/F (67/67N), Negative Phase Sequence O/C (46) ,Inrush Detection (68), Circuit Breaker Failure Protection (50BF), Broken Conductor (46BC), Three Phase O/V, U/V & NDR (27, 59, 59N) ,Thermal Overload (49),Negative Sequence Overvoltage (47) ,Reverse Power (32),Over Frequency (81O), Under Frequency (81U), CT Supervision (60 CTS) ,VT Fuse Failure (60 VTS),Relay shall have 8 DI and 8 DO. Makes: ABB/CG/Schneider/Siemens. 112 B. OUTGOING - 6 Nos ( Each consisting of )11kVIndoorSwitchgear Panel consisting of Breaker-1250A, 25kA draw out type having following accessories for Transformer Outgoing.a. 230VAC Spring Charge Motor.b.110VDC Closing Coil.c.110VDC Shunt Trip Coil.d. Current Transformer Indoor Single Phase Resin Cast Ratio: 400-300-200/5-5A Core-1: 15VA Class 0.5, Core -2 5P20 - 3 nos.e.12 Window Annunciator.f.Digital Ammeter with ASS.g. Digital Voltmeter with VSS.h. Multifunction Load Manager Class 0.5 with RS485 & Ethernet communication.i. Master Trip Relay, TCS Relay , TNC Lockable Type, Manual/Remote Selector Swithc etc.,j. Numerical Protection IEC 61850 Draw out Relay with Graphical display- 1nowith Three Phase O/C & E/F (50, 51, 50N, 51N, 50G, 51G),Three Phase Directional O/C & E/F (67/67N), Negative Phase Sequence O/C (46) ,Inrush Detection (68), Circuit Breaker Failure Protection (50BF), Broken Conductor (46BC), Three Phase O/V, U/V & NDR (27, 59, 59N) ,Thermal Overload (49),Negative Sequence Overvoltage (47) ,Reverse Power (32),Over Frequency (81O), Under Frequency (81U), CT Supervision (60 CTS) ,VT Fuse Failure (60 VTS).Relay shall have 8 DI and 8 DO. Makes: ABB/CG/Schneider/Siemens. 113 C. BUSCOUPLER- 1 Nos ( Each consisting of )11kVIndoorSwitchgear Panel consisting of Breaker-1250A, 25kA draw out type having following accessories for Transformer Outgoing.a. 230VAC Spring Charge Motor.b.110VDC Closing Coil.c.110VDC Shunt Trip Coil.d. Master Trip Relay, TCS Relay , TNC Lockable Type, Manual/Remote Selector Swithc etc.,e. Electrical & Mechanical Interlocking, ABT scheme with Manual option.Note: The above said panelsEarthing truck -02 nos. Separate earthing truckfor bus earthing & cable earthing. Earthing truck shall be so designed that it is impossible to earth alive. It shall be provided with capacitive voltage detection with audio visual annunciation. Technical drgs of the VCB panel submitted by the contractor is required to be approved by the accepting officer before taking procurement action and the VCB panelto be inspected by rep of the accepting officer at Factory premises as per IS before despatch. Pre-commissioning inspection of VCB panelshall be carried out by Senior Electrical Inspector / Electrical Inspector. The VCB panel should be GSM based SCADA compatible. 114 Supply, install, test and commission of APFC panel indoor type 1500 KVAR 12.1 KV, complete Make : CG / Shreem /Siemens /BCH.Capacitor panel consisting of below:-83.33 KVAR, 6.98 KV, externally fused capacitor unit for 250K @12.1KV (207K 11KV) step - 12nos.166.67 KVAR, 6.98 KV, externally fused capacitor unit for 500K @12.11 KV (413K 11KV) step - 3nos.11 KV, Air core dry type, class F aluminium wound, 1Ph, 0.2%, series reactor (STC shall be 16.6 times rated current for 2 sec) - 15nos.11KV, 400A, 10KA for 1 Sec, 3 phase vacuum contactor - 15nos.11 KV/110V-190V, 50-50VA, 3Ф resin cast RVT - 1no.11 KV HT HRC fuses of suitable current rating- 15nos.11 KV, 630Amp, 25KA for 1 sec, off load type isolator- 1no.3PH, RC surge suppressor- 1no.APFC relay (RS485/232 communication port)- 1no.Control cable, space heater, timer, thermostat, CFL lamp, LED indication, push button, selector switch, terminal connectors, gasket, limit switch, name plate, hardware - 1 set. 115 S& F spring loaded aluminium clamps suitable for HV & EHV cables of following sizes inculding all necessary items to fix such as nuts, bolts, washers etc. and all fixing arrangements as required at site. 116 Single core 630 Sqmm 132 KV Al cable 117 Three core 300 Sqmm 33 KV Al cable 118 M & L for survey, site inspection, layout design and location identification for complete earthing/earth mat layouting for best result depending on the soil condition at the site of 132KV and 33 KV yard all complete as specified and directed. Survey report alongwith layout drawing in A3 size properly verified by a Engineer to be submitted in triplicate for approval of Engr in charge/GE 119 Material and labour for brick massonary in cement mortar 1:4 of internal size 1000 x 1000 x 800mm for man hole in contol/power cable routes including plastering with cement mortar 1:6 10MM thick internally and externally 150mm below the G.L. with 1:6 cement mortar 15mm thick,PCC 1:4:8type D2 by using 40mm gradded aggregate foundation of size 1550x1550 mm of 150mm thick and PCC 1:3:6 for coping of 50mm thick and covering the chamber with 40X40X4 mm thick angle iron frame and 10mm thick RCC slab with type B0 1:2:4 concrete with 12.5mm graded aggregate as cover with handles made out of MS round bar 10 mm dia for lifting slabs including painting to the angle iron with two coats of synthetic enamel paint over a coat of redoxide primer and white wash for the man hole complete all as directed by Engineer-in-charge. 120 Material and labour for brick massonary in cement mortar 1:4 of internal size 1500 x 1500 x 1400mm for man hole in control cable routes including plastering with cement mortar 1:6 10MM thick internally and externally 150mm below the G.L. with 1:6 cement mortar 15mm thick,PCC 1:4:8type D2 by using 40mm gradded aggregate foundation of size 1550x1550 mm of 150mm thick and PCC 1:3:6 for coping of 50mm thick and covering the chamber with 40X40X4 mm thick angle iron frame and 10mm thick RCC slab with type B0 1:2:4 concrete with 12.5mm graded aggregate as cover with handles made out of MS round bar 10 mm dia for lifting slabs including painting to the angle iron with two coats of synthetic enamel paint over a coat of redoxide primer and white wash for the man hole complete all as directed by Engineer-in-charge. 121 M&L for Providing precastreinforced cement concrete slabs 12.5 cm thick M-30 including reinforcementand 12 mm dia MS handle (with plain or interlocking joints as directed setting in mortar 1:6 of size of slab 1.20x1.20M. 122 LIGHTENING PROTECTION 123 M & L for single pointed Air termination Aluminium Rod 12 mm dia 500 mm long with Aluminium base plate of size 125 x 125 x 10mm fixed over hylam sheet of size 175 x 175 x 10mm and fixed on 1.5 Meter GI pipe 25mm Medium grade on roof all specified and as directed. 124 M & L Earthing complete with GI earth plate electrode 60cmX60cmX6 mm thick buried directly in ground (earth pit not less than 2.25 mtrs deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connecting to galvanized earth strip 32 x 6 mm as earthing conductor by means of bolts, nuts, check nuts and washers of GI and all as shown in Electrical plate No.3 of SSR Part I and including testing on completion all as specified locations and as directed by the Engineer-in-Charge.Note: 1.The above quoted rate shall include cost of main earthing lead of 32 x 6mm GI earth strip, charcoal, salt, excavation and earth work in any type of soil CI cover, funnel with 20mm dia medium grade GIwater pipe including GI protection pipe 40mm dia light grade for earth strip etc., 2. The cost of earth pit is deemed to be included in the unit rate. 125 AC & REF 126 Supply and install split AC units indoor/outdoorof capacity 2 TR, 3 star , Inverter type, single phase complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with copper condenser complete all as specified and directed 127 S& F Voltage Stabiliser 5 KVA, operating voltage range 130-290 Volt, Single phase complete all as specified and directed. 128 SCHEDULE A PART-IXPHASE -II Outsourcing for sub station for the First 11 Monthsduring Defect Liability Period . 129 Outsourcing for manning and operationof HT/LT Electrical sub station at 33/11 KV substation at NSB along with connected equipments installed round the clock (in 03 shifts) of each shift of 08 hours per day including Sunday and holidays complete all as specified and as directed. 130 One skilled operator in each shift 131 One semi skilled operator in each shift 132 SCHEDULE A PART-XPHASE -III Outsourcing for sub station for the Second 11 Monthsduring Defect Liability Period . 133 Outsourcing for manning and operationof HT/LT Electrical sub station at 33/11 KV substation at NSB along with connected equipments installed round the clock (in 03 shifts) of each shift of 08 hours per day including Sunday and holidays complete all as specified and as directed. 134 One skilled operator in each shift 135 One semi skilled operator in each shift 136 SCHEDULE A PART-XIPHASE -IV Outsourcing for sub station for the balance 02 Months after 22 months during Defect Liability Period . 137 Outsourcing for manning and operationof HT/LT Electrical sub station at 33/11 KV substation at NSB along with connected equipments installed round the clock (in 03 shifts) of each shift of 08 hours per day including Sunday and holidays complete all as specified and as directed. 138 One skilled operator in each shift 139 One semi skilled operator in each shift 140 Note for Item No. 127 to 138:-The rate shall include the following[i] For operation of all out door and indoor structures in the same area.[ii] Contractor shall laise with Dolphin hill sub station in case of major breakdown for early restoration of supply.[iii] In case any problem occurs which seems not under thecontrol of the operator, the same shall be immediately intimated to JE/ AGE E/M.[iv] Any additional man power required for early restoration of supply in case of emergency shall be provided by the contractor.[v] The contractor shall abide by the latest labour rules and minimum wages Act. Wages paid by the contractor to the emplopyed persons shall not be less than minimum wages fixed by the state/ central Govt from time to time whichever is higher.[vi] The contractor shall also insure the workmen employed on th job.[vii] The contractor is responsible for insurance, EPF, ESI, labour welfare cess etc., as applicable and shall be paid to the workmen as per existing Rules/ Acts/ regulations etc., and quoted is deemed to include the same. 141 SCHEDULE A PART-XIIPHASE -VOutsourcing for SCADA system for the First Year after Defect Liability Period . 142 Operation and comprehensive maintenace without manning of SCADA system including cost of spares post defect liability period operation including payment of bills by telecom service provider (Contractor to provide monthwise break down details of the same) complete all as specified and as directed. 143 SCHEDULE A PART-XIIIPHASE -VIOutsourcing for SCADA system for the Second Year after Defect Liability Period . 144 Operation and comprehensive maintenace without manning of SCADA system including cost of spares post defect liability period operation including payment of bills by telecom service provider (Contractor to provide monthwise break down details of the same) complete all as specified and as directed. 145 SCHEDULE A PART-XIVPHASE -VIIOutsourcing for SCADA system for the Third Year after Defect Liability Period . 146 Operation and comprehensive maintenace without manning of SCADA system including cost of spares post defect liability period operation including payment of bills by telecom service provider (Contractor to provide monthwise break down details of the same) complete all as specified and as directed. 147 SCHEDULE A PART-XVPHASE -VIIIOutsourcing for SCADA system for the Fourth Year after Defect Liability Period . 148 Operation and comprehensive maintenace without manning of SCADA system including cost of spares post defect liability period operation including payment of bills by telecom service provider (Contractor to provide monthwise break down details of the same) complete all as specified and as directed. 149 SCHEDULE A PART-XVIPHASE -IXOutsourcing for SCADA system for the Fifth year after Defect Liability Period . 150 Operation and comprehensive maintenace without manning of SCADA system including cost of spares post defect liability period operation including payment of bills by telecom service provider (Contractor to provide monthwise break down details of the same) complete all as specified and as directed. 151 SCHEDULE A PART-XVIIPHASE -XOutsourcing for SCADA system for the Sixth year after Defect Liability Period . 152 Operation and comprehensive maintenace without manning of SCADA system including cost of spares post defect liability period operation including payment of bills by telecom service provider (Contractor to provide monthwise break down details of the same) complete all as specified and as directed. 153 SCHEDULE A PART-XVIIIPHASE -XIOutsourcing for SCADA system for the Seventh year after Defect Liability Period . 154 Operation and comprehensive maintenace without manning of SCADA system including cost of spares post defect liability period operation including payment of bills by telecom service provider (Contractor to provide monthwise break down details of the same) complete all as specified and as directed. 155 SCHEDULE A PART-XIXPHASE -XIIOutsourcing for SCADA system for the Eighth year after Defect Liability Period . 156 Operation and comprehensive maintenace without manning of SCADA system including cost of spares post defect liability period operation including payment of bills by telecom service provider (Contractor to provide monthwise break down details of the same) complete all as specified and as directed. 157 Note for Item No. 140 to 155 [i] Cost of all minor spares/ components including OFC cables, Ethernet switches, connectors etc., is deemed to be included in quoted rate and any type of extra charge will not be made by Dept.[ii] All major defective spares shall be replaced by contractor on exchange basis which is deemed to be included in the unit price.[iii] All periodical tests of all safety devices in accordance with relavant safety standards with full oad testing will be borne by the contractor.[iv] Systematically examine & repair all the components such as software, monitors, servers etc., if any defect found,[v] All required special tools to be arranged by the contractor.[vi] Contractor shall be responsible for maintaining adequate lighting, cooling and moisture control, ventilation as required all at site complete.[vii] All safety measures/ directions and required tests for safety devices annually shall be borne by contractor.[viii] All periodical visits and all breakdown calls related to stoppage, malfunction, special services should be attended compulsory during all days including sundays & holidays.[ix] The contractor shall be liable to pay the telecom bill provided by the service provider.
Contract Date: Jan 06, 2026 Contract Value : 23.55 Crore
Statutory Bodies & Commissions/Committees No of Bidders 7
Andhra Pradesh View Result →
Contract Date: Mar 29, 2026 Contract Value : 1.27 Lakh
Government Departments No of Bidders 1
14.
Defence #9609242 AOC
Tender For Repair, Maintenance And Replacement Of Ht Cables, Gods, Vcbs, Rmus, Transformers And Connected E And M Items At Af Stn Suratgarh; 1 Excavation in trenches in soft/loose soil not exceeding 1.5 mtr in depth and not exceeding 1.5 mtr wide for laying of cables, erection of poles,struts, stays etc and getting out all as specified and as directed by Engineer-In-Charge. 2 All as per item No. 1 here-in-before but in PCC/floor/road 3 All as per item No. 1 here-in-before but depth exceeding 1.5 metre and not exceeding 3 metre 4 Returning, filling in including spreading, levelling, watering and well ramming excavated soil in layers not exceeding 25 cm thick each, filling back in trenches after cables have been laid and tested, poles,stays,struts have been erected and tested complete all as specified. 5 Removal of excavated surplus soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all asspecified. 6 M&L for boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding techniqueand necessary machine or manually without damage nearby electric cable, water pipe line etc including HDPE pipe of 100 mm dia suitable for 0.4 mpa working pressure and sealing the end of pipe complete all as specified and directed. 7 M&L for laying GI Tubing light grade 100 mm dia for cable potection in road/ floor all as specified and directed 8 Supplying and laying ofsize 90 mm dia (OD-90 mm & ID-75 mm nominal) DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc.conforming toIS 14930, Part II complete with fitting and cutting, jointing etc direct in ground (90 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 9 Supplying and laying ofsize 120 mm dia (OD-120 mm & ID-103 mm nominal) DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc.conforming toIS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (90 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 10 Taking out HT/ LT cable of any size/ description from trenches/ floors/ road/ wall/ pipe/ pole and removing & reusefrom site incl making good the disturbed surfaces to match with existing surface all as directed. 11 Relaying/ Labour only for fixing or passing through pipe, laid in trenches or fixed to pole/wall or fixed to panel board/ VCBat existing places or provided by MES forcarrying to other location, upto 33000/11000 volts grade heavy duty cable with XLPE/PVC insulated stranded aluminium conductor served with inner sheathing of PVC tape, armoured with galvanised steel wire or tape and overall PVC sheathed of size upto 300 sqmm 3 core obtained from item No.10above with required aluminium cable lugs, heat shrink joints specified and directed.Note:The cableJoints and protection pipe and Earth work (if cable laying new rout)shall be meausred seperatly. 12 Supply, laying in trenches/ with pole, jointing and testing of HT 11 KV rated XLPE insulated, PVC bedded earth system stranded aluminium conductor cable 3 core, 95 Sqmm inclusive all incoming and out-going electric connections, complete all as specified and as directed. 13 All as per item No 12 above but of size 3 core 120 sqmm 14 All as per item No 12 above but of size 3 core 150 sqmm 15 All as per item No 12 above but of size 3 core 300 sqmm 16 S&F in replacement cable jointing kit for 11 KV (earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm complete all as specified and as directed. 17 All as per item No 16 above but joint of size 120 to 185 sqmm 18 All as per item No 16 above bu joint of size 240 to 300 sqmm 19 S&F in replacement cable jointing kit for 11 KV (earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm complete all as specified and as directed. 20 All as per item No 19 above butjoint of size 120 to 185 sqmm 21 All as per item No 19 above butjoint ofsize 240 to 300 sqmm 22 S&F in replacement cable jointing kit for 11 KV (earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm complete all as specified and as directed. 23 All as per item No22 above but straight through joint of size 120 to 185 sqmm 24 All as per item No 22 above but straight through joint ofsize 240 to 300 sqmm 25 S&F in replacement cable end termination, outdoor, heat shrinkable type joint complete with jointing material and accessories suitable for 33 KV, 3 core 300 sqmm, XLPE armoured aluminium conductor cable complete all as specified and directed. 26 All as per item No 25 above but indoor type joint 27 All as per item No 25 above but straight through type joint 28 Supply and fixing cable route indicator for HT UG cable of 11000 Volts bolted with 40x6mm flat iron member of height 0.90m and 80mm dia CI plate, embeded in PCC 1:3:6 type C-2 of size 20cm x20cm x30cm block complete all as specified and as directed by Engineer-in-Charge. 29 Supply and fixing pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut 150mm height, 150mm dia for working pressure 11000 Volts grade of HT line including taking down existing cracked/unserviceable pin type insulator complete all as specified and directed. 30 S&F in replacement pin type, porcelain, vitreous, white, brown or green insulator/ polymer including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, for 33KV grade complete incl taking down old/unsv all as specified and directed. 31 Supply and fixing disc type insulators, porcelain vitreous white brown or green, 145mm hight and 255mm dia ball and socket type, single disc assembly for tension with tension clamps for conductor having working pressure 120 KN for11000 Volts /33000 volts (use suitable string ) with highest voltage capacity 12 KV including taking down existing cracked/unserviceable disc type insulator complete all as specified and directed. 32 Taking down old U/S GO switch any type and size from HT 2/4 poles structures. 33 S & FGang operated switch outdoor type 11000 Volts, 200 Amp capacity tripple pole machenically operated suitable for operation from ground level and for vertical mounting complete with HT insulators 9 Nos., channel, knife blades, GI pipe medium grade 25 mm dia for operating mechanism worked from ground level , locking arrangement with handle all as specified. 34 S & FGang operated switch outdoor type 11000 Volts, 400 Amp capacity tripple pole machenically operated suitable for operation from ground level and for vertical mounting complete with HT insulators 12 Nos. with dropout fuse set, channel, knife blades, GI pipe medium grade 40 mm dia for operating mechanism worked from ground level, locking arrangement with handle all as specified. 35 All as per item No 34 but for 33 KV 400 Amp, operating horizontal direction incl taking down old/unsvall as specified and directed 36 S&F in replacement expulsion fuse unit single pole mounted on insulator & steel frame complete with fused barrel (drop out fuse) suitable for 11 KV for current rating upto 20 Amp incl taking down old/unsv fuse unit complete all as specifed and directed. 37 S&F in replacement HT 33 KV outdoor type dropout fuses double stack channel type complete with insulator of rating up to 400 Amps incl taking down old/unsvcomplete all as specified and directed. 38 Repairing / Servicing the Air break isolating switch HT 11 KV 200/400 Amps by replacingthe defective major spares parts including provn of minor bolts nuts etc all as specified and directed.Note: Major spare parts will be measured & paid seperately under relevant items of Sch-A 39 Supply only Male contact/ moving Contact Blade 40 Supply only Female contact/Fix Contact Jaw 41 Supply only Tinned copper Flexible jumper 200A/400 A 42 Supply only MS jumper carrier 43 Supply only Back Connector plate 44 Supply only Petroleum Jelly 45 Dismantling/ Taking down old unserviceable lightning arrestor 11 KV from HT 2/4 poles structures. 46 M&L for HT 11 KV lightening arrestor expulsion type having discharge capacity of 65 KA, suitable for 11 KV HT line includng making connection with existing GI earth wire. 47 S&F of lightning arrestors expulsion type complete with all fittings, suitable for 33 KV grade transmission class, discharge capacity 65KA including brackets, clamps, nuts washers and connecting to 4 mm dia GI earth wire including taking out old unservicable lightining arrester allcomplete all as specified and directed. 48 Supply and fixing of Jumper for HT OH Lines 33/11 KVbus system to GOD and GOD to DO Fuse unit with jumper made of aluminium conductorinsulated with colour coding, (Red Green , Blue) with all conneted item i.e nut bolt, U G clamps etc up to length of size 3 to 5 Mtr all as specified and directed by Engineer -in-charge. 49 Dismantling concrete poles/ struts of any size complete all as specified and directed. 50 Demolition of concrete (coping of PCC/ GI pole/ Road) of any description and in any position 51 Supply and erecting in true vertical position steel tubular swaged pole, 11 metre long, complete with mild steel base plate 6mm thick of size 300mm x 300mm, B-118 finial taper plug, bolts, nuts, washers and screws, type 410 SP-55 including drilling of holes of required size and nuts for fixing of cross arms, painting with two coats of aluminium paint over a coat of red oxideand two coats of black bituminous paint for portion embedded in concrete, painting five black and white bands at lower portion of pole each of 300 mm height at 300mm spacingcomplete all as specified and directed.(Note : Excavation, earth work and PCC in foundation of poles, coping etc shall be measured and paid separately under respective items of Sch A). 52 PCC 1:2:4 (nominal mix) type B-2 using 40mm graded crushed stone aggregate, as in coping of poles and the like complete including weathering, slightly rounded or chamfered angles and throating all as specified and directed. 53 PCC 1:3:6 (nominal mix) type C-2 using 40mm graded crushed stone aggregates, as in foundation filling and mass concrete for poles and stay/installation paths complete all as specified and directed. 54 M&L for PCC 1:2:4 type B1 using 20mm graded aggregate in coping of size (0.65x0.55x0.45) Mtr for PCC/RCC/Steel tubular pole complete with 10mm thick cement plaster CM 1:4 on coping surface complete all as specified and directed. 55 M & L for scrapping of old painted surfaces of electric pole covered by dust and other depositedmaterials by cleaningwith wire cup brush on drill /grinderfromsteel tubular pole of length upto 11 metres including cross arms,bracing, clamps etc and painting with one coat of Epoxy zinc phosphate primer and including two coats of synthetic enamal paint upto 1.50 mtr height having alternative existing strip (white and black or Red and yellow )of 30 cm height each, all as specified & directed by Engineer-in-Charge. 56 M & L for scrapping existing deteriorated complete removal of old paint bywith wire cup brush on drill /grinderfrom the steel tubular 2 pole structure of 9.0-11.0 mtr height above ground levelwithout removing accessories and preparation of surfaces for repainting the poles with and including two coats of synthetic enamal paint upto 1.50 mtr height having alternative existing strip (white and black or Red and yellow )of 30 cm height each, including one coat ofEpoxy zinc phosphate primer to the remaining part of pole (i.e above 1.50 mtr height) and its cross arms, bracing, support and all steel members complete all as specified and directed. 57 All as per Ser item No. 56 above but for 4 pole structure. 58 All as per Ser item No. 56 above but for 6 pole structure. 59 Dismantling ACSR or AAC conductor complete all as specified and directed. 60 Supply andfixing aluminium conductor, steel reinforced (ACSR) of following sizes as in overhead conductor including fixing aluminium tapes for binding complete all as specified and directed: -(a) 6/1 x 3.0- Ferret (b) 6/1 x 2.59- Weasel(c) 6/1 x 2.11- Squirrel Note: The weight of the conductor shall be determined as stipulated in Preamble (b) & (c)on Page 384 of SSR-2010 Part-II (Rates). 61 M& L for Stringing of ACSR conductor any size to HT/LT over heads lines, streching properly to achieve proper sag including binding to insulators using GI/aluminium binding wire all as specified and as directed by Engineer-in-Charge. 62 M& L for Stringing of GI cradle Guaredconductor any size to HT/LT over heads lines, streching properly to achieve proper sag including binding to insulators using GI/aluminium binding wire all as specified and as directed by Engineer-in-Charge. 63 M&L for restraining of GI wire of any size on pole after disconnecting all binding on cross arms and redoing all bindings providing required T&P all as specified and directed 64 Supply and fixing PVC moulded LT Line separator suitable for 4 lines OH system. Make- Denson/Mex-well/JB/Jaipuriya brothers 65 Surface excavation over the areas around the substations not exceeding 45 cm depth and averaging 30 cm deep and getting outspoil inhard & dense soil including levelling the surface. 66 M&L forscreened river sand/ tibba filling on the levelled ground surface/ducts in sub stations/below 2 pole & 4 pole structures etc 67 M&L stone aggregate of size 35 to 40mm spreading over sand layerin the substation areas including proper leveling all as directed and shown at site. 68 M&L stone aggregate of size 20 to 25mm spreading over sand layer in the sub stations areas including proper levelling all as directed . 69 M&L taking out spreadedaggrgate of any size &sieving the aggrgate & dust/ sand & relaying the aggregate after sieving in the sub stations 70 M&L brick work with sub class B brick straight cured on plan exc 6m mean radious built in cm 1:4 71 Rendering/cement plastering 15mm thick on fair faces of brick work or concrete surfaces in Cement mortor 1:4 finished even and smooth without using extra cement 72 S & F Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk),forming holes of Fe 410-W (Gde E- 250) quality without any attachmen use for cable duct cover at substncomplete all as directed. 73 M&L for replacement of earth pit chamber of size 300 x300 mm (internal dimensions) and 450x450mm(External)with PCC 1:3:6 type C-1 , RCC 1:2:4 type B-1 reinforced with 6 mm dia MS round bars @ 15 cm c/c both ways for cover 50 mm thick with 12 mm dia MS hook of suitable size and shape for lifting and MS angle iron frame 50 x 50 x 4 mm including GI funnel with wiremesh complete all as specified. 74 Material and labour for fixing of display Board of 60cmx30cm forearth pit made out of 2 mm thick MS sheet welded on angle iron legs 0.75 mtr long (02Nos) of size 40x40x6mm duly embeddedin PCC block 1:2:4, type B-1, using gradedcrushedstone aggregate, of size 23x23x30cm fixed in ground including necessary earthwork. Display Board shall be painted with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by Engineer-in- Charge. The following is to be written on the board:- (a) Earth Pit No. -(b)Connected To -(c) Checked on -(d) Next due date.-(e) Ohmic Value 75 Cutting and uprooting grass, vegetation shrubs, bushwood undergrowth, roots and trees not exceeding 30 cm girth (measure one metre above ground level) in and around electrical sub stations, two/four pole structures and removing rubbish to a distance upto 50 metres outside the periphery of the area, complete all as specified and as directed by Engr-in-Charge. 76 Supply and fixing of synthetic insulating matsuitable for 11 KV installation of size 1.00 m x 2.00 m and 25mm thick (ISI marked) complete all as specified and directed. 77 Supply and fixingEarthing dischard rod(ISI Marked), extendable upto 18 feet height with rubber hand grip and suitable size copper wire suitable for working with 11 KV HT lines complete all as specified and directed. Make: Jaipuria/Rashtriya Electricals 78 Supply and fixAluminium thimble/lugs suitable for 50 sqmm to 95 sqmm XLPE cable all as specified and directed. 79 Supply and FixAluminium thimble/lugs suitable for 120 sqmm to 185 sqmm XLPE cable all as specified and directed. 80 Labour for disconnecting LT/HT cable of any size from structure/pole/transformer for finding fault, M&L for defect rectification LT/HT cable laid in trenches or any location by liacting fault with the help of electronic fault machine comprising of surge generator pulse, ECHO fault locator with high frequency distance calculator etc. The entire repair work to be completed with in 12 hours of instruction from Engr-in-charge as specified. Note:- Complaint will be notified to contractor on mobile phone at any time between 0800 to 2200 Hrs and has to be rectified with in 12 hours after notification, failing to which Rs500/- per day complaint will be recoverd. fault locating with electronic fault locator, excavation and earth work, disconnecting and reconnecting both end of cable, relaying of sand and protective cable covers are deemed to be included in the quioted rate all as specified and directed by Engineer-in-charge.Note: joint kit will be measured seperately in appropriate item in this schedule 81 Labour only for disconnecting LT/HT cable of any size from pole (height 7.5 to 9 mtr) /transformer/panel and re-connecting ofcable at both endafter removing carbon /burnt insulation part of cable by cutting refixing cable withnew cable lugs . The entire repair work to be completed with in 06 hours of instruction from Engr-in-charge all as specified. Note:- Complaint will be notified to contractor on mobile phone at any time between 0800 to 2200 Hrs and has to be rectified with in 06 hours after notification, failing to which Rs 500/- per daywill be recoverd per complaint. 82 M&L for earthing complete with GI earth plate 600x600x6mm thick electrode and 32x6 mm GI strip as earthing lead buried directly in ground (Earth pit not less than 2.25 Mtr deep below ground level) with top edge of the plate not less than 1.5 Mtr below normal ground connected to GI strip earth lead by means of bolts, nuts, check , nuts and washers of galvanised iron or steel all as shown on electrical plate no. 3 including 40 mm dia medium grade GI protection pipe, 20mm dia GI medium grade watering pipe, funnel, wire mesh , charcoal dust, PCC pit and 50mm thick RCC cover, earth work in any type of soil connected to earthing test point complete all as specified and as directed.Note: GI stripbeyond 7.5Mtr length from earth electrode shall be measured and paid separately). 83 All as per item No 82 above but with 4 mm dia GI wire as earthing lead andGI protection pipe 20mm dia medium grade. 84 M&L for earthing complete with copper earth plate 600x600x3.15mm thick electrode and 20x3 mm copper strip as earthing lead buried directly in ground (Earth pit not less than 2.25 Mtr deep below ground level) with top edge of the plate not less than 1.5 Mtr below normal ground connected to copper strip earth lead by means of bolts, nuts, check , nuts and washers of copper all as shown on electrical plate no. 3 including 40 mm dia medium grade GI protection pipe, 20mm dia GI medium grade watering pipe, funnel, wire mesh , charcoal dust, PCC pit and 50mm thick RCC cover, earth work in any type of soil connected to earthing test point complete all as specified and as directed.Note : Copper strip & GI pipe 40mm dia beyond 7.5mtr length from earth plate shall be measured & paid separately under respective item) 85 S&F earthing strip 32x6mm GI fixed to wall/pole/buried in ground /drawn in pipe complete. 86 S&F earthing strip 20x3.0 mm copperfixed to wall/pole/buried in ground /drawn in pipe complete. 87 S&F GI wire 4mm dia iron fixed to wall/pole/buried in ground /drawn in pipe complete. 88 S & F Danger notice plate for HT poles size 1.6 mm thick mild steel sheet vitreous enemelled white letter figures and converntionl skull and bones maked in red colour with MS clamp of flate iron 25X3mm size, bolts, nuts, size of plate 25 X20 Cm complete all as directed by Engineer-In-Charge. 89 Dismantling unserviceable any size of cross arms from pole /structures/anti-climbing device etc complete allas specified and directed. 90 M&L for MS work confirming to Fe-410-O or Fe-310-O as in cross arms, support, bracings, stiffeners, clamps channels fabricated from structural steel including nuts, bolts and washers welding, bending cold or hot drilling holes for bolts in any shape or size all as directed including two coats of aluminium paint over a coating of red oxide primer all as directed by Engineer-In-Charge. 91 M&L for anti climbing devices, spike type fabricated out of MS bars (Round, square and flat) including nuts, bolt, washers and welding in two halves made to shape to suit the cross section of the pole including painting etc complete all as specified and as directed. 92 Cutting/trimming of tree branches under OH LT/HT electric line including cleaning upto 3.00 mtr horizontal distance on both sides of OH electric line from ground level of the poles including removing all creepers smal bushes etc of under OH line upto 60 mitre each span complete all as specified and directed.Note: Materials/T&P like Axies, Daw, rope and the like will be provided by the contractor without any extra cost to the Govt. 93 M&L for stay assembly complete with MS stayplate 300x300x6mm thick galvanized stay rodnot less than 20mm dia, 2.15 M long galvanized stay bow, galvanized thimble,stay clamp etc. all as shown in electrical plate No1of SSR part-I.Note:- Excavation,earthwork,cement concrete loop type insulators and stay wire shall be measured and paid separately under relevant items. 94 M&L for Galvanised stay strand, size 7/4mmcomplete. 95 M&L for loop insulator, vitreous, porcelain, white, brown or green, large size with overall dimensions 50x140mm clearance of hole 25.5 mm complete. 96 Overhauling/ servicing /calibration of HT VCB 400/630 Amps 33 KV of any make by carrying out following job:-(i) Taking out VCB trolly from the panel board.(ii) Removal of dirt,dust & carbon particles by air blower(iii) Cleaning of all moving & fixed contacts of VCB with dry cloth & CRC solution and greasing of moving contacts & gears.(iv) Checking and setting of VCB ON/OFF operation mechanism through TNC & push button and triping relay and adjust the trip setting.(v)Checking tightness of all control wires.(vi) Checking leakage in vacuum interrupter by Hi-Pot test.(vii) Assembly of trolly and testing complete.(viii) Servicing shall be got carried out by authoised rep of the VCB manufacturer and the service engineer submit a service report of each VCB with detais of settings perameter.Note: Spare parts shall be undertaken through authorised service centre of OEM as directed by the Engineer-in-charge. 97 Overhauling/ servicing /calibration of HT VCB 400/800 Amps 11 KV of any make by carrying out following job:-(i) Taking out VCB trolly from the panel board.(ii) Removal of dirt,dust & carbon particles by air blower(iii) Cleaning of all moving & fixed contacts of VCB with dry cloth & CRC solution and greasing of moving contacts & gears.(iv) Checking and setting of VCB ON/OFF operation mechanism through TNC & push button and triping relay and adjust the trip setting.(v) Checking tightness of all control wires.(vi) Checking leakage in vacuum interrupter by Hi-Pot test.(vii) Assembly of trolly and testing complete.(viii) Servicing shall be got carried out by authoised rep of the VCB manufacturer and the service engineer submit a service report of each VCB with detais of settings perameter.Note: Spare partsshall be undertaken through authorised service centre of OEM as directed by the Engineer-in-charge. 98 Supply and fixing in replacement microprocess numerical relay for 33/11 KV VCB tripping system ( 03 Over Current/02 O/C , 01 Earth Fault and high set instantaneous protection in single unit) suitable for opration on 24V DC-110V DCall as per Model No CGI14N/CGI4C of Make: Crompton Greaves or equivalent in AREVA(Note:ifExisting relays are of Electromagnetic type, hence any modification in the wiring,and panel sheet enclosure is deemed to be inclusive in the scope of work). 99 Supply and fixing in replacement Ammeter for HT panel Square dial of size 100 mm digital type complete all as specified and as directed.Make : AE/Rishabh (Note: Existing meter analough type and large in size, hence any modification in the wiring,and panel sheet enclosure is deemed to be inclusive in the scope of work). 100 Supply and fixing in replacement voltmeter for HT panel Square dial of size 100 mm digital type complete all as specified and as directed.Make : AE/Rishabh(Note: Existing meter analough type and large in size, hence any modification in the wiring,and panel sheet enclosure is deemed to be inclusive in the scope of work). 101 M & L for Vaccum Interrupter type WL-33379 or as per exixtingsuitable for 11 KV VCB Panelcomplete all as specefied and directed. 102 M & L for Isolating contact assembly 400/800 Amps with complete set of contact (set of six) suitable for 11 KV VCB Panelcomplete all as specefied and directed. 103 Supply and fixing in replacement indicator lamp assembly 24V DC in (Red,Yellow, White, Green & Blue colour) for HT panels complete all as specified and as directed. 104 Supply install, testing and commissioning in replacementof Power packunit input voltage 90-270 Volts and out put voltage 24 Volts DC having4-digit degital Volt & Ammeter, High resolution D/A, A/D converter , Digital interface as standard function etc. including taking out US battery bank unitcomplete all as specified and as directed 105 Supply install, testing and commissioning in replacement of Power packunit input voltage 110 Voltage and out put voltage 24 Volt DC having4-digit degital Volt & Ammeter, High resolution D/A, A/D converter , Digital interface as standard function etc. including taking out US battery bank unit complete all as specified and as directed 106 Supply and fix Motor cut off switch complete all as specified and directed 107 Supply and fix ZZ Switch complete all as specified and directed 108 Supply and fix HRC Kit kat fuse 2A, 4A,6A ,10A & 20 A complete all as specified and directed 109 Supply and fix Closing coil 24V DC complete all as specified and directed. 110 Supply and fix Tripping coil 24V DC complete all as specified and directed 111 Supply and fix of Multifunction meter (V,A,P,PF) for 11 KV VCB as per existing sample complete all as specified and directed. 112 Supply and fix of Big gear and small gear set complete all as specified and directed. 113 Supply and fix of TNC switch 11 KV/33 KVpanel complete all as specified and directed. 114 Supply and fix Segment gear complete all as specified and directed. 115 Supply and fix of 11 KV Spring charging motor 220V AC/DC complete all as specified and directed. 116 Supply and fix Motor & Gear assembly 110V DC and 220 ACfor 11 KV VCB Panelcomplete all as specefied and directed. 117 M&L for painting to VCB,Fire stand post ,duct plate etc atinstallations with two coats of synthetic enamel paint after making the suface free from oil/grease/rust and applying a coat of red oxide primer complete including writing details as per directed like as SM Nos/feeder detail etc. all as specified and as directed. 118 S & F in repair Aux relay Buch/WTI/OTIfor 11 KV VCB panel ,Auxiliary supply 24Volt DC as per existing complete all as specified and directed. 119 S & F Cast resin type 11KV VCB three phase current transformer having ratio 100+50/5+5Aas per IS: 2705 having protection core class 5P10, burden of 15VA and metering core class CL1.0 and burden of 15VA, breaking capacity of 13.1 KV for 1.0 second 120 S & f 11KV VCB three phase indoor oil cooled PT of ratio 11KV/RT 3/10V/RT 3/110/RT 3 class 0.5-3, burden 100VA, insulation level 35/75 KV, voltage factor 1.2 cont and 1.9 for 30 sec, conforming to IS-3156 121 S&F in replacement HT fuse wire upto 60 amp asper site requirement mounting on insulator of 2 Pole/4 Pole structure complete with fused barrelfor 11 KV complete all as specifed and directed. 122 Disconnecting, opening of HT Capacitor bank of any description and any make of rating 11 KV indoor capacitor switching APFC paneland outdoor capacitor bank type with automatic/manual control having output 2400 KVAR (Step rating proposed : 400 KVAR x 2+800 KVAR x 2 desired 0.99) for servicing / overhauling, taking out and removing unserviceable / defective parts including cleaning & servicing, greasing, oiling of the parts etcand replacement of unserviceable parts with new one, reassembling the HT Capacitor Bankafter overhauling/ servicing and its testing complete all a specified and directed. Note:Replacement of unserviceable parts shall be measured and paid for separately under appropriate item of Sch A as supply only 123 Spply only HT HRC Fuses suitable for 11 KV, 400 KVAR complete all as specified and directed. 124 Spply onlyHT HRC Fuses suitable for 11 KV, 800 KVAR complete all as specified and directed. 125 Spply only NDVR Relay suitable for 400 KVAR step complete all as specified and directed. 126 Spply only Contactor coil 127 Spply only Copper bus bar 50x10 mm length 1 mtras per site requirement 128 Dismantling and taking down by removing HT and LT connection of indoor /outdoor type 11/0.433 KV transformer of capacity up to 200 KVA from existng platform/4 Pole/inside sub station Lowering the same carefully and shifting to other location within Air force station(both tech & resdential) as directed by Engineer-in-charge with and including re-installation by means of arrangement and testing and including additional/alterationfoundation according manufactures complete all as specified and directed . Note : (a) Installation of transformer , testing and connecting the both HT/LT cables , commissioning of transformer after checking voltage and loading at full load shall deemed to be included in quoted rates .(b) Contractor shall provide necessary tripod, chain & pulley, T&P, etc for transportation, the rent and foundation for additional/alteration shall deemed to be included in the quoted rate. 129 All as per srl item No128, abovebut capacity of transformer more than200 KVA andupto 500KVA complete all as specified and directed . 130 Repair to distribution transformer step down 11/0.433 KV indoor/outdoor type of capacity 100 KVA to 250 KVA, after dismantling the transformer carefully, opening the top cover of transformer for inspection /repair, draining out the transformer oilfrom the housing complete, taking out the core and winding by disconnecting the internal connections, removing the carbon/sludge deposit in transformer housing core, replacement of unserviceable rubber bushes and washers, replacement of tap changer winding and thimbles, replacement of silica gel, replacement of top cover gasket set including pasting with pasting material, replacement of worn out nut and bolts, replacement of unserviceable LT & HT bushes, cutting the burnt out winding and re-winding the same with suitable size of super enamelled copper/aluminium wire as per existing guage, insulating the winding connection by using fire proof sleeve and fire proof tape, varnishing the coil, keeping the coils in electric oven chamber for 24 hrs to remove the moisture, painting of complete transformer body from outside and inside, marking of MES/SM Number etc, replacement of conservator tank glass, re-installing the core and winding inside properly, making the all connection with suitable copper lugs, filling of new transformer oil, reinstalling the top cover after cleaning and painting of housing, conservator tank, expulsion vent etc, Meggering the LT and HT side of the Transformer and testing complete all as specified and directed by Engineer-in-Charge. Note :- (i) Winding wire for making of coils, HT/LT bushes, new transformer oilwill be measured & paid seperately(ii) Contractor is required to submit test report for repaired transformer duly signed by Engineer-in-Charge before installation. 131 All as per Srl item No 130 above but of capacity 11 / 0.433 KV, above 250 KVA upto 630 KVA complete all as directed. 132 S & F in replacement brass terminal rod with nuts , boltswasher and bushing suitable for HT and LT side of the transformer of any make and capacity upto 200 KVA complete all as specified and directed . 133 All as per srl item No132, abovebut capacity of transformer more than200 KVA andupto 630KVA complete all as specified and directed . 134 S & F in replacement tap changing switch suitable for operation on 11/0.433 KV distribution transformer with tappings on 2.5% , 5% and 7.5% on requirement basis for upto 630 KVA capacity transformer complete all as specified and directed . 135 Supply and Filling in replacement superior quality silica jel inside the breather assembly and fixing properly with transformer complete all as specified & directed. 136 S & F in replacementoil valve for drain out/filling in screwed both ends with iron wheel head suitable for transformers up to 200 KVA capacity complete all as specified anddirected. 137 All as per srl item No 136, abovebut capacity more than 200 KVA andupto 630 KVA complete all as specified and directed . 138 M & L for fabrication HT / LT side box covers made of bakelite sheet10 mm thickness with proper nuts bolts incl cutting sheet to required size , drilling holes for nuts/bolts etc complete allas specified and directed. 139 S & F in replacement oil temperature gauge 0 -120 degree analogue dial type for transformer complete all as specified & directed 140 M & L for filteration and dehydration of transformer oil by dehydration machine to achieve the die-electric strength/ insulation value upto65 KV/40KV (RMS) atstandardgap of electrodes 2.5 mm for one minute in 33 KV/11 KV transformer capacity 3 MVA TO 5 MVA including insulation testing of oil with help of suitable equipments before and after dehydration including BDV Test compete all as specified and directed.Note:(i) Contractorwill have to arrange the dehydration machine and transformer oil dielectric strength testing equipmentas mentioned and same shall be deemed to be included in the item rate quoted.(ii) Test result of transformer oil before and after dehydartion is required to submit by contractor duly signed by all concerned. (iii) The contractor shall ensure that the conservator tanks are full to its level before commencement of dehydration process. (iv) Additional quantity of transformer oil if any required for making the oil level upto the requirement in transformer shall be measured and paid separately as supply and filling but its cost of heating shall be deemed to be included in the rate quoted for above item. 141 Supply and filling transformer power oil meeting IEC 60296-2003-11, 3rd edition standard specification and ASTMD 1275B test requirements for corrosive sulpher of BDV not be less than 70 KV at 2.5mm gap for reduced level of transformer due to evaporation/ leakage/losses due to dehydration in HT33 KV transformer/HT 11 KV AVR transformer/11 KV distribution transformer all as as specified and directed. 142 Supply only super enameled copper conductor wire of suitable gauge and size as per requirement for rewinding of 33/11/0.433 KV power/distribution transformer complete all as specified and directed . 143 Supply only super enamelled aluminium conductor wire of suitable gauge and size as per requirement for rewinding of 11/0.433 KV distribution transformer complete all as directed. 144 Supplying and fixing in replacement, Porcelain Transformer bushing on LT (440 Volt) side, including brass stems conical bush and gasketafter disconnecting electrically and mechanically for indoor/outdoor transformer of capacity upto 160 KVA andre-connecting electrically and mechanically, testingcomplete all as specified and directed. Note.The rates quoted is deemed to be included the cost of necessary labour charges for draining out & re-filling transforer oil,opening of top cover by unscrewing nut, bolts washers andsuitable size pad type bus bar almuminium and nut bolt washers. 145 All as per Serial item No144 here-in-before butcapacity 200 KVA to 315 KVA 146 All as per Serial item No 144 here-in-before but capacity 400 KVA to 630 KVA 147 Supplying and fixing in replacement, Porcelain Transformer bushing on HT (11 KV) side, including brass stems conical bush and gasketafter disconnecting electrically and mechanically for indoor/outdoor transformer of capacity upto 160 KVA andconnecting electrically and mechanically, testingcomplete all as specified and directed. Note.The rates quoted is deemed to be included the cost of necessary labour charges for draining out & re-filling transforer oil,opening of top cover by unscrewing nut, bolts washers andsuitable size pad type bus bar almuminium and nut bolt washers and reconnection 148 All as per Serial item No 147 here-in-before but200 KVA to 315 KVA 149 All as per Serial item No 147 here-in-before but 400 KVA to 630 KVA 150 Supplying and fixing in replacement,all unserviceable gasketafter disconnecting electrically and mechanically for indoor/outdoor transformer of capacity upto 200 KVA andre-connecting electrically and mechanically, testingcomplete all as specified and directed. Note.(i) The rates quoted is deemed to be included the cost of necessary labour charges for draining out & re-filling transforer oil,opening of top cover by unscrewing nut, bolts washersetc. (ii)Joint shall be leak proof and any leakage noticed after repair work shall be rectified by the contractor without any extra cost to the deptt. 151 All as per Serial item No 150 here-in-before butmore than 200 KVAand up to 630 KVA 152 S & F in replacement, Silica Gel Breather assembly including vent pipe and Silica Gel for indoor/outdoor transformers,capacityupto 200 KVA complete all as specified and directed. 153 All as per Serial item No152 here-in-before butcapacity more than 200 KVA and upto 630 KVA 154 Supply and fixing in replacement 3mm thick Sheet glass (each not exceeding 0.9 Sqm) ordinary quality and glazing with oil putty on cabin of OTI and WTI gauge of transformer upto capacity 630 KVA complete all as specified and directed. 155 Supply and fixing in replacement thermometer of transformer upto capacity 630 KVA complete all as specified and directed. 156 M & L for cleaning and preparation of steel surfaces of existing dull painting of transformer outdoor type including radiators, cooling ducts, vent pipes, condensor etc and applying two coats of synthetic enameled paint (heat resistant type)according to to IS colour code by spray machine including writing MES /SM No. in capital letters of suitable size on body for capacity upto 160KVA transformer outdoor/indoor complete all as specified and directed 157 All as per item No: 156 but capacity above 200 KVA and upto 630 KVA. 158 Repair to distribution Power transformer 33/11 KV outdoor type of capacity 3 MVA to 5 MVA , after dismantling the transformer carefully, opening the top cover of transformer for inspection /repair, draining out the transformer oilfrom the housing complete,replacement of unserviceable rubber bushes and washers, replacement of tap changer winding and thimbles, replacement of silica gel, replacement of all gasket set including pasting with pasting material, replacement of worn out nut and bolts, replacement of unserviceable HT bushes, painting of complete transformer body from outside and inside, marking of MES/SM Number etc, replacement of conservator tank glass, filling of new transformer oil, reinstalling the top cover after cleaning and painting of housing, conservator tank, expulsion vent etc, Meggering the Transformer and TTRtesting with complete all as specified and directed by Engineer-in-Charge. Note :- Transformer oil /Winding wirewill be measured & paid seperately(ii) Contractor is required to submit test report for repaired transformer duly signed by Engineer-in-Charge before installation. 159 Supply and fix inreplacement WTIrelay suitable for 3.15 MVA /5 MVA transformer control panel completeall as specified and directed by Engr-in-charge. 160 Supply and fix inreplacement OTI relay suitable for 3.15 MVA/ 5 MVA transformer control panel complete incl taking down unsv all as specified and directed by Engr-in-charge. 161 Supply and fixinreplacement Mastertripping relay with display suitable for 3.15 MVA/5 MVA transformer control panel complete incl taking down unsvall as specified and directed by Engr-in-charge. 162 Supply and fixinreplacement Differntial protectionrelay with display suitable for 3.15 MVA/5 MVA transformer control panel complete incl taking down unsvall as specified and directed by Engr-in-charge. 163 Supply, fixing and testingin replacement Buchholz relay with display suitable for 3.15 MVA/5 MVA transformer control panel complete incl taking down unsvall as specified and directed by Engr-in-charge. 164 Supply and fix inreplacement Over/Under voltage protectionrelay with display suitable for 3.15 MVA/5 MVA transformer/ 33 KV VCBcontrol panel complete with testing and calibrationincl taking down unsvall as specified and directed by Engr-in-charge. 165 Supply & Fixmarshaling box complete with all sensor/Meter/indicatorfor protection of winding temprature , oil temprature etc suitable for 5 MVA/3MVA Transformeror as per existing incl connection andtaking down unsv all as specified and directed. 166 M&L for overhauling of the 11 kV Automatic Voltage Regulator (AVR) involves a comprehensive inspection, cleaning, testing and restoration process to ensure reliable performance and accurate voltage regulation. The scope includes the following :-(a) Initial Inspection: Visual and mechanical inspection of the AVR and associated components to assess overall condition and identify faults or degradation.(b) Dismantling: Safe removal and disassembly of the AVR unit including checking connections, terminals and internal assemblies.(c) Cleaning: Removal of dust, oil, moisture, and other contaminants using appropriate cleaning agents and techniques.(d) Component Testing: Electrical testing of control circuits, sensing mechanisms and regulating components to detect wear, drift or failure.(e) Replacement of minorParts: Replacement of defective or worn-out components such as resistors, capacitors, relays, or control cards with compatible, high-quality spares. 167 (f) Reassembly and Calibration: Reassembling the AVR and performing calibration to manufacturer specifications for optimal voltage regulation performance.(g) Final Testing: Functional testing under simulated or actual load conditions to verify stability, response time and output regulation.(h) Reporting: Preparation of a detailed service report including findings, actions taken, test results and recommendations.Note :- (i) Restore the AVR to its original working condition with improve efficeincy andreliable operation of the 11 KV system.(ii) The above work shall be carried out by the authorised manufacturer and rate for the same are included in this item. Nothing shall be paid extra on this account. Note :- Following Major spare parts will be measured & paid seperately 168 Supply only AVR Carbon roller assemblycomplete all as specified and directed 169 Supply only tag and tail assey AVRcomplete all as specified and directed 170 Supply only B4c limitt switchcomplete all as specified and directed 171 Supply only PCB sensing relaycomplete all as specified and directed 172 Supply only Motor 40 KG with Gearcomplete all as specified and directed 173 Supply only Delta change flip flopcomplete all as specified and directed 174 Supply only TDR 240 V AC complete all as specified and directed 175 Supply only Aux Contactorcomplete all as specified and directed 176 Supply, installation, testing and commissioning of 11 kV, 630 Amp, 3 Pole, Outdoor Type Load Break Switch (LBS) with manually operated gang mechanism, suitable for breaking load current under normal service conditions, complete with insulators, arcing horns, operating mechanism, earth blades, padlocking arrangement and all other necessary accessories for safe and efficient operation ,The LBS shall be mounted on hot dip galvanized steel support structure duly fabricated with base frame, operating pipe, crank and handle, including providing and casting of cement concrete foundation in 1:3:6 type C-2 (using 40 mm graded stone aggregate) with necessary excavation, formwork, curing and finishing smooth, including grouting of bolts and painting of steel structure with two coats of aluminium paint over one coat of red oxide primer, complete all as specified and directed by Engineer-in-Charge.
Contract Date: Feb 16, 2026 Contract Value : 31.31 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 4
15.
Defence #9609205 AOC
Tender For Provision Of Watering Facility, Bty Charging Room And Lighting For Arf At Cod Delhi Cantt-10.; 7 S&F exhaust fan of metallic body single phase 230/240 Volt AC of size 380 mm sweep, 1400 RPM heavy duty with louvers complete all as specified & directed. 8 S&F ceiling fan 1200 mm sweep efficiencia DX BLDC model with five star rating white colour including with all necessary accessories ie speed regulator, rubber reel, clamps, locking pins, nut bolts, canopy & down rod complete all as specified and directed. 9 Supply, layingjointing,testingDIpipe with class-K-7 spigot socketed ends , conforming to IS-8329 laid in trenches of 100mmbore dia of pipe complete all as specified and directed. (Note : Tyton Joint, Excavation & earth work shall be measured & paid separetely.) 10 Material and labour for DI specials like bends, tapers any type any radius and angle, Tee pieces single branch `Y junction, double branch, cross (all sockets or socket and spigot) collars, DI connecting pieces one end flanged and other end spigot/socket, reducers/bell mouth pieces one end flanged and other end tapering as bell mouth for the size up to 250 mm dia bore. 11 Material and labour including jointing and testing of cast iron sluice valves class PN-1.0, conforming to IS:14846 flanged ends drilled having stainless steelspindle with cast iron wheel at top complete with nuts, bolts, washers and rubber gaskets including taking out unserviceable sluice valve and removal from sitefor 100mm bore complete all as specified and directed. 12 Supply and installation of flanged ends Water Meterwoltman type, including testing and making good connection with flanged ends, with gasket rubber sheet and nut & bolts etc ISI Marked fixing in horizontal/incline/vertical position,including taking out unserviceable of 100 mmbore complete all as specified and as directed. 13 M&L for installation of flanged ends strainer/dirt box, PN-10 with stainless steelmesh suitable for water meter for potable water supplies on up stream of water meter to avoid foreign material entering into meter including taking out unserviceable of 100 mmbore complete all as specified and as directed. 14 Supplying , laying , jointing, welding and testing MS Pipe (Heavy class C) IS : 1239/3589, of followiing sizes laid in trenches or in Horizontal/Vertical/inclined position orlaying on floors for connectionsfor suction, to header andconnected to out going water main CI/DI pipe line, for 100 mm DiaNote:- MS Flangesincluding fabrication work will be measured and paid separately. 15 Supply and fixing in renewal of MS flange 100 mm bore ,16mm thick duly welded with flange joint including nuts bolts ,washer ,Rubber or fiber board gasketjoint of 100 mm size complete all as specified and directed. 16 Supply, install, testing & commissioning of Factory Made 11 KV, 400 Amps, 21 kA for 3 Seconds, SF6 Insulated, Motorized, Outdoor, 3 Way RMU Consisting of 2 Nos VCB Incoming and 1 Nos VCB Outgoing for Feeder complete all specified and as directed and shall comprise of the following: 17 [A] RMU shall be 11 KV, 400 Amps, 21 kA for 3 Seconds, SF6 Insulated, Motorized, Outdoor, 3 Way RMU, Right side Extensible with Air Insulated Bus Connected Metering unit, Type tested in line with latest IEC Standards, suitable for operations at a height up to 1000 Meters above sea level and at 40ºC Ambient Temperature without any de-rating, Switchgear and Busbar shall all be contained in a Stainless Steel Enclosure [Minimum 2mm thick AISI 441 Grade] filled with SF6 at 0.3 Bar [300 hPa] Relative Pressure, RMU Tank shall provide Full Insulation and Switchgear shall be insensitive to the environment with Degree of Protection of IP67 immersion for 30 minutes as per IEC Standard 60529, Switchgear Operating Mechanism shall have an IP2X Protection and Cable Chamber shall have IP3X Protection, Outer Enclosure shall be IP 54 type tested, Powder Coated with Pure Polyester Based Paint, suitable for the site installation conditions, Accidental Overpressure due to an Internal Arc is limited by the opening of the safety valve, at the bottom of the metal enclosure, away from the operator, Plug in type of extensibility must be provided and coupling busbar should not be exposed to air to avoid oxidation of busbars. Extension of cubicle shall require 450mm to handle and the gap between the coupled RMU’s must be within 10mm. 18 [B] Vacuum Circuit Breaker [VCB], comprising of the following: [i] 11 KV, 400 Amps, 21 kA VCB with Manual / Motorised Spring Assisted Mechanism and Series Trip Coil – 1 No, [ii] Load Break Switch with Built-In Earth Switch – 1 No[iii] Position Indicator through clear front mimic in line with IEC 62271-103 – 1 No[iv] Self Powered Relay with O/C, S/C, E/F Protection. Relay shall have a Front USB / RS485 / RS232 Port for Laptop Interface / Modbus Communication, LCD Display, 10 Event Records, 5 Fault Records, min 2 setting group and keypad for setting parameters for the relay – 1 No[v] CT Ratio 200-100/1-1A for Incoming, 100-50/1-1A for Outgoing and, Class - 1.0, 2.5VA for Metering and Class 10P10, 2.5 VA for Protection – 1 Set[vi] Live Cable Indicator with indication at the Front and Three Inlets to check the Synchronization of Phases – 1 No[vii] Cable Termination Bushing suitable for up to 1 Run, 3 Core, 185 Sq.mm, XLPE Cable – 1 Set[viii] Cable Termination Cover Boots [Push on type] – 1 Set[ix] Fault Passage Indicator FPI. 19 [x] Circuit Breakers shall have Two Positions: Open or Disconnected and Closed. A separate and independent 3 Position Earthing Switch and disconnector shall be fitted to open and earth the cables in such way that interlocks prevent all unauthorised operations. An operating mechanism shall be used to manually close the circuit breaker and charge the mechanism in a single movement. An independent mechanism shall be fitted for the 3 Positions Earthing Switch and Disconnector Circuit breaker shall be fitted with a local system for manual tripping by an Integrated Push Button. There shall be no automatic reclosing. Circuit Breaker shall have a min of 2000 Mechanical and Electrical Operations and 50 Nos Short Circuit Operations, Disconnector and Earth Switch shall have a minimum of 1000 [M1] Mechanical Operations, 100 Electrical Operations at rated current and 5 Nos Operations at Rated Short Circuit Current.[C] Air Insulated Bus Connected Metering Unit comprising the following: – 1 Set[i] Air Insulated Enclosure with necessary Bus Connection – 1 No[ii] PT 11KV / RT 3 / 110V / RT3, 25 VA, Class-1.0 – 1 Set[iii] Voltmeter with Selector Switch – 1 No[iv] R / Y / B Indicating Lamps – 1 Set 20 [vi] Battery and Battery Charger, 12 Ah, [I/P-230V AC, O/P - 24V DC] – 1 No[v] 11 KV / 230V AC, 1 KVA Control Transformer-1 No[vii] Self Powered FRTU to detect Short Circuit and Earth Fault on the Cable System, Fault indication through LED Lamps, Reset through Remote and Local. As a minimum, the FRTU shall be capable of performing the following functions: [a] Acquiring Analog values from Multifunction Transducers or alternatively through Transducer – less modules and the status inputs of devices from the substation, processing and transmitting to Master stations. Capability to acquire analog inputs from analog input cards receiving standard signals viz. Current Loops 4 – 20 mA, etc.[b] Receiving and processing Digital Commands from the Master Station[s] [c] Data transmission rates – 300 to 19200 BPS for Serial ports for MODBUS and 10/100 MBPS for TCP/IP Ethernet Ports[d] Use of IEC 60870-5-104 Protocol to communicate with the Master Station[s][e] Use of MODBUS over RS485 interface, Protocol to communicate with the MFTs, Protection Relay. 21 [f] Have required number of Communication Ports for simultaneous communication with Master Station[s], MFTs.[g] FRTU shall have the capability of Automatic Start-Up and initialisation following restoration of Power after an outage without need of manual intervention. All restarts shall be reported to the connected Master Stations.[h] Remote Database downloading of FRTU from Master Station from SCADA/DMS Control Center.[i] Internal Battery Backup to hold Data in SOE Buffer Memory & also maintaining the Time & Date.[j] Communication with at least Four Master Stations simultaneously on IEC 60870-5-104[k] RTU shall be capable of Acquiring Analog Values through Transducers having output as 4-20 mA, 0-10 mA, 0-+10 mA etc using Analog Input Modules.[l] FRTU shall have one TCP/IP Ethernet Port for communication with Master Station[s] using IEC 60870-5-104 Protocol.[m] FRTU shall have one Serial RS 485 Port for communication with MFTs and connected in daisy chain using MODBUS Protocol. Minimum 15 Analog Values [Including 4 Energy Values] shall be considered per energy meter. 22 [viii] Connection with adjacent modules shall be direct through busbar via metering bushing or through MV cables. VT’s and CT’s from the manufacturer conforming to IEC61869-3 and IEC 61869-2 respectively shall be accepted.Note:[a] The make of Vacuum Interrupter, FRTU offered shall be of the same make as of the Ring Main unit.[b] An operator situated in front, lateral and rear [A-FLR 21kA – 1 Sec, Downwards Exhaust, for Tank as well as Cable Compartment] of the RMU Switchboard during an internal fault shall not be exposed to the effects of Arcing. Internal Arc Type Test Report for IAC AFLR 21 kA for 1 Sec for both Tank & Cable Box shall be for minimum 3 Way / 3 Function RMU.[c] All operations shall be from front of the RMU, including access to cable bushings. Bushings along the sides or the rear of the RMU are not acceptable. 23 [d] Construction of Plinth / Foundation for 11KV RMU: The rate quoted is deemed to be including the cost of Plinth / Foundation and shall be paid extra on this account. The foundation shall consists of Two Parallel Brick Walls built using Fly Ash bricks straight or curved on plan to any radius built in Cement Mortar 1:6 of length 2.10m, suitable thickness and height as per the manufacturer’s instructions over PCC Concrete Bed of 150mm thick in PCC 1:4:8, Type D-2, using 40mm graded stone aggregate over 150mm thick Hardcore of gauge not exceeding 63mm of broken stones or boulders, deposited, spread and levelled in layers not exceeding15 cm thick watered and rolled, over 150mm thick Sand Bed, rendering to brick surfaces, 15 mm thick in Cement Mortar 1:4, and finishing the top surface even and smooth without using extra cement, applying Three coats of white washing including earthwork excavation of pit size 2.10 X 1.20 X 0.60 Metres complete all as per manufacturer’s recommendations, drawings, as specified and as directed.[e] The rate quoted is also deemed to be including the cost of disconnection of HT Cables up to 3 Core, 240 Sq.mm from existing 2 Pole / 4 Pole Structures, removing of cable loop and reconnection to RMU complete all as specified and as directed by the Engineer-in-Charge.[f] End termination joints shall be measured and paid separately. 24 Supply, Installation, Testing & Commissioning of OEM Factory Manufactured, Floor Mounted, Outdoor Type,ICOG (Cable-In, Cable-Out) type,HT 11 KV Air Insulated VCB Panel Switchboard consisting of 400 Amps, 25 KA, VCB 11 KV – 1 Nos, VCB Panel shall be Outdoor Type totally enclosed, Free Standing Floor Mounting Type, compartment based with Truck Mounted Vacuum Circuit Breaker, Spring Operated, Electrically and Manually charged Operating Mechanism suitable for Horizontal Isolation, Horizontal draw out type VCBs with Aluminium Busbars, Self supported Insulated Busbar with full voltage rated, Complete VCB Panel conforming to IEC 62271-200 Standards and IP 4X Class of Protection comprising necessary bus-bars extension and connections and following Protective and Control Devices as specified below. Vacuum Interrupters of the circuit breakers shall be completely encapsulated in epoxy housing. Circuit Breaker, Vacuum Interrupter and Relay shall be of the same manufacturer. The Switchgear and Control Gear Panels shall be of the fully Arc Proof complete all as specified and as directed.Make: ABB / CG / Schneider / Siemens. 11 kV Outdoor Switchgear Panel consisting of Breaker of capacity 400 Amps, 25 kA Draw out type and shall have the following accessories: [a]230 Volts AC Spring Charge Motor 25 [b]110 Volts DC Closing Coil[c]110 Volts DC Shunt Trip Coil[d]Current Transformer, Indoor Resin Cast Ratio: 100-50/5-5A Core – 1: 15VA Class 0.5, Core – 2 15 VA 5P10 Core -3.[e]Potential Transformer Resin Cast Ratio: 33KV/√3/110V/√3 50VA, CLASS: 0.5 – 3 Nos[f]12 Window Annunciator[g]Digital Ammeter with ASS[h]Digital Voltmeter with VSS[i]Multifunction Power Meter Class 0.5 with RS485 & Ethernet Communication [j]Master Trip Relay[k] Numerical Relay Differential Protection [87T] - 01 No. 26 [l]Numerical protection IEC 61850 Draw out Relay with graphical display- 1 No. with three phase O/C & E/F (50,51, 50N, 51N, 50G, 51G), three phase Directional O/C & E/F (67/67N), Negative phase sequence O/C (46), Inrush Detection (68), Circuit Breaker Failure Protection (50BF), Broken Conductor (46BC), Three phase O/V, U/V & NDR (27, 59, 59N), thermal overload (49), Negative sequence over voltage (47), reverse power (32), Over frequency (81O), under frequency (81U), CT Supervision (60CTS), VT Fuse Failure (60 VTS), Auto recloser (79), relay shall have 8DI and 8 DO. [m] Power pack 100W with battery back up.Makes: ABB/CG/Schneider/Siemens. 27 Supply, installation, testingand commissioning in replacement of factory made testedLT Panel compartmentalized cubicalOutdoor type canopy headed Floor mounted suitable for , 415 volts 3 phase, 4 wire,50 HZ AC supply system having bus bar chamber with insulated aluminum bus bar of rating 1.5 times that of controlling MCCB supported on SMC insulator. The panel should be dust and vermin proof IP -65 class protection and made of 3.15 mm CRCA MS sheet and 50X50X6 mm thick MS angle iron frame work, powder coated finish over one coat of red oxide primer on out side surface and painted in side with two coat of red oxide primer and rear opening type with apron for cable entry, closing locking arrangement including internal wiring with PVC insulated solid copper conductor FRLS cable IS 694 marked , 1100 volts grade of appropriate size and comprising of the following including necessary foundation platform of suitable size 28 NOTE:-(i) All incoming and outgoing feeder shall be connected by cable through suitable size glands & thimples. (ii) All MCCB Should have spreader link with barrier. (I) Incoming :- (i) MCCB 4P, 630 A, 36 KA, Icu = Ics = 100%, thermally adjustable between 60 to 100% - 01 Nos.(ii)Digital Voltmeter 0-500 volts, square, 96 mm,flush pattern with 3 way selector switch - 01 No(iii)Digital Ammeter 96mm x 96 mm,flush pattern with 3way selector switch- 01 No.(iv) 3 Nos of CTs ofratio500/5 copper wound, Class 1.0, 10 VA – 1 Set(iv) Indicating lamps R,Y and B Phase :01 set of three(II) Outgoing :-(i) MCCB 4P, 400 A, 25 KA, Icu = Ics = 100%, thermally adjustable between 60 to 100%= 02 Nos.(ii) MCCB 4P, 100 A, 16 KA, Icu = Ics = 100%, 415 Volt, 50 Hzs= 02Nos. 29 Boring of hole under road/pavement/hard standing or any other situation by manual means and suitable for passing ofHDPE/GI pipe 80 to 100 mm bore and making good both ends complete all as specified and directed. 30 Demolition of road, path, drain and concrete in ground floors, RCC/Brick wall (below or above ground level) complete all as specified and as directed. 31 Platform :- M&L for Brick Masonry ( Using sub class B Brick) platform of size 3m x 3m x 1 m height , built in CM 1:4 complete with excavation & earth work , PCC 1:4:8 type D-2 in foundation , 15 mm thick rendering in CM 1:6 on sides and top of the brick work , up to 150 mm below ground level , supply and fixing of 02 Nos MS Channels ofsize ISMC-100for balancing of Transformerembedded in PCC 1:2:4 type B-1 up to 100 mm thick RCC 1:2:4 with 10 mm steel bar including 20 mm graded aggregate , including provn of steps on one side complete all as specified and directed . 32 S&F for Angle iron, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers,welding, bending cold or hot,drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete all as specified and directed.. 33 Supply drawing, connecting and testing of3 core, 2.5 Sqmm PVC insulated and PVC round sheathed copper conductor (flexible ) industurial cable, 1100 Volts conforming to IS 694 complete all as specified and directed. 34 S&F 4 mm thick mild steel wire 75x25 mm mesh up into mattressess or cages, lapped wired and fixed in position including welded for fencing to grid including one coat of primer and two coat ot synthetic enamel paint complete all as specified and directed.
Contract Date: Feb 19, 2026 Contract Value : 79.61 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 5
16.
Communications and Information Technology  #9403747 Technical Bid
Attending Day To Day Fault, Repairing And Mtce. Of Od Type Tfr. Substation And Rewinding Of 25Kva, 11Kva/0.433 Kv Oil Cooled Tfr. With Asso. Works At Various T.E. And Mobile Bts Sites Under Sambalpur Ba For The Year 2025-26 (For Blg And Bpt Oa); 1 Attending to break down calls, physical inspection of Substation accessories, overhead lines, feeder panels, meter box etc. to find out thefaultsand taking corrective measures for restoration of power supplyi/c minor repairing works i/c replacement of insulators, LAs, jumpers, lugs/sockets etc. in coordination with supply authority etc. as required. 2 Liaison with different units of the supply authority i.e. Field units, MRT units, Division office etc.forobtaining shut down of 11KV line, breaking of meter sealif required to carry out the major repairing and maintenance works of the Transformer substation/replacement/rewinding and re-installation of the repaired Transformer, re-energisation, testing and re-commissioning etc.as required. 3 Thorough servicing of AB Switch, adjustment of bearings, male/female contacts, lubricating of movingitems i/c replacement ofminor defective parts like nuts, bolts, clamps, wire braided copper strips and checking the functional operation,etc.as required. 4 Replacement of the following defective spare parts ofthe transformer substation by new one i/c fitting, connectionetc. as reqd.(a) Male contact and Female contacts made of hard drawn copper for 200 Amps air break switch with wire braided strip etc. comprising of 3nos per set. 5 Rotor mechanism for 200 Amps air break switch. 6 Square/round bar for AB switch (Horizontal unit) 7 11KV Post Insulator for 200Amps AB switch/ HG fuse unit 8 Operating Handle made of 25/32mm Medium class GI pipe with wire braided copper strip 9 Heavy duty operating pipe for air break switch i/c fabrication etc. as required. 10 Replacement of faulty/damaged pin insulators by new oneof 11 KV grade pin type insulator with large steel head G.I. pin, nuts, washers on existing HT pole/ DP structure etc. complete as required. 11 Replacement of faulty/damaged discinsulators by new one of 11 KV, 45 KNporcelain disc insulator with galvanized insulator fittings, ball and socket type and complete with galvanized strain clamps, bolts, nuts, washers etc. as required. 12 Replacement of damaged and unserviceable AB switch of the following typeby new one of11 KV, off load, single break, triple pole, horizontal type, gang operated air break switch having 2 nos. 11 KV post type insulator per phase complete with galvanized channel iron base, arcing horns, 25 mm dia. 6mtr. long GI pipe, tinned copper wire braided flexible earthing wire & operating handle with locking arrangement etc. complete as required.(a) 200 A Horizontal type 13 (b) 400 AHorizontal type 14 Supply & drawing of 55 sqmm. AAA conductor for overhead line and DP structures i/c binding with insulators etc. complete as required. 15 Dismantling of existing faultyHT cable3 core, 11 KV grade XLPE insulated ,galvanised steel armoured earthed type 35 sqmm stranded Al conductor power cable overall PVC sheated from overheadalong with one no 55 sqmm AAAconductorload bearer wirei/cnecessary meggering /identificationof fault etc complete as required.( 1 span=30mtrs ) 16 Replacement of faulty 11KVoutdoor type cable end terminationsby new one ofheat shrinkabletype complete with all accessories including lugs suitable for 3 core, 35 sqmm, XLPE aluminium conductor cable of 11 KV grade as required. 17 Replacement of faulty/burnt outstraight through cable jointsby new one of outdoor typeheat shrinkable type complete with all accessories including lugs suitable for 3 core, 35 sqmm, XLPE aluminium conductor cable of 11 KV grade as required. 18 Rewiring of the DP structure of Transformer Sub Station with 55sqmm AAA /50sqmm insulated Al.conductor stranded cable with al. Lugs/sockets, binding with post insulators etc. complete as required. 19 Replacement of faulty/burnt out cables by new one including Laying offollowing sizesPVC insulated & PVC sheathed Aluminium conductor armoured cable 650/1100 V. grade confirming to IS : 7098 (Part-1) 1988i/c transportation to respective sites etc. as required. (a) 4 core 16 sqmm 20 4 core 25 sqmm 21 Replacement of damaged MV cable end terminationswith brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. (a) 4 X 16 sq. mm (28mm) 22 4 X 25 sq. mm (28mm) 23 Replacement of thedefective parts/components by new ones of following sizes & ratingsaluminium/copper sockets/lugsforPVC sheathed / XLPE aluminium/copper conductor cable of 1.1 KV grade i/cfixing/crimpingetc. as required. (a)16/25 sqmm Al socket. 24 35 sqmm Al socket. 25 55 sqmm Al socket. 26 Dismantling the following ratings faulty transformer from the existing D.P. structure/Plinth & installation of standby/repaired transformer i/c testing and commissioning, recording the required parameters etc. by qualified staff, arranging required tools & plant with proper precautionary measures etc. as required. (a) 25 KVA, 11KV/0.415KV, 50 Hz Aluminium wound oil cooled Transformer 27 Repairing of 25KVA Aluminium/ copper wounded transformer at site i/c opening top cover, checking the bush, inter connectionswires/strips from bushings to transformer windings, tightening the connections, etc.as required. (Rewinding of Transformer is not in the scope of this item) 28 Rewinding of the HT windings ofthe following ratings Oil immersed Distributionclass Transformerwith superior grade andsuitable size Double paper coveredTransformer winding conductor , providingre-insulation of LT winding etc. includingdismantling the transformer parts i.e. conservator tank, terminal boxes, bushings, removing the core and windings from the tank, draining of transformer oil, cleaning of tank,reassembling the core & windings and all the aforesaid parts after rewinding/repairing but excluding transformer oil, replacement of gaskets, worn out nuts, bolts and washers/cork washers etc, heating in heat chamber, carry out factory testsand submission of test reportsetc.complete as required. (The dismantled aluminium winding and other materials can be retained by the agency and credit for the same to be given in the quoted rate of this item)(a) 25 KVA, 11KV/0.415KV, 50 Hz Aluminium wound oil cooled Transformer. (Note - Transformer oil will be measured separately) 29 (b) 63 KVA, 11KV/0.415KV, 50 Hz Aluminium wound oil cooled Transformer. (Note - Transformer oil will be measured separately) 30 Supplying and pouring of transformer oil (IS:325) of suitable make & grade for topping up/replacement of old deteriorated oil etc. complete as required. 31 Replacement of damaged feeder pillar with a newly fabricated one ofsize 450mm x 350 mm x250 mm deep made having 16 SWG MS sheet, duly powder coated with superior quality enamel paint after one coat of red oxide paint to accommodate one no SDFU (Excluding cost of spare)i/c providingangle iron mounting structure for support etc i/c grouting etc complete as required . 32 Transportation of spare/new/repaired/standby 25/63 KVA transformer from BSNL office /factory /workshop to respective sites and faulty Transformer from sites to back by using suitable transportation medium including loading and unloading at both ends etc. complete as required. (The rate should be inclusive of toll gate fee/charges wherever applicable, nothing extra will be paid. Distance will be on shortest route only). (a) Distanceup to and including 50 KMs (Up and Down) 33 Distanceabove 50 KM and up to and including 100 KMs (Up and Down) 34 Distanceabove 100 KM and up to and including 150 KMs (Up and Down) 35 Distanceabove 150 KM and up to and including 200 KMs (Up and Down) 36 Supply and erection of 9 mtrs. long PSC pole (conforming to IS: 1678/ 1998 as amended up to date) with working load 300 Kg. at 600 mm from topwith earthing arrangement in no. 8 SWG GI wire including transportation of the same from factory to site, loading and un loading at both ends, errection of the same for LT line support with 1.5 mtr. planting depth, earthing arrangement in no. 8 SWG GI wire, rigidly supported at the butt end with cement concrete foundation 1:2:4(1 cement, 2 sand & 4 stone aggregate) of size 600mm x 600mm wide and 1600mm depth i/c excavation, refilling etc. complete as required. 37 Laying and drawing of existing repaired HT cable3 core, 11 KV grade XLPE insulated ,galvanised steel armoured earthed type 35 sqmm stranded Al conductor power cable overall PVC sheated on overhead along with one no 55 sqmm AAAconductorload bearer wirecomplete as required.( 1 span=30mtrs ) 38 Cuttingof trees , bushes , shrubs etc in the sub station area i/ccleaning with the help of required T&P etc cpmplete as required 39 S/FMS channel/ V Cross arms , F clamp etc of suitable size /c cutting , welding ,jointing etc i/c painting with red oxidecomplete as required 40 Reimbursement on account of payment made to TPWODL for testing fee of repaired transformer as per details given below (a) Transformer testing fee
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 1
17.
Power #9336524 Technical Bid
RATE CONTRACT FOR UPKEEP / MAINTENANCE OF EXISTING 33/11 kV RECEIVING STATIONS ALONG WITH THEIR 33 kV LINES AND FABRICATION & HANDLING OF MATERIAL OF DIVISIONAL STORE UNDER THE JURISDICTION OF SUB-TRANSMISSION DIVISION-I, JPDCL, JAMMU FOR THE YEAR2025-26- 1 Erection of 16 mtr long Steel Tubular Pole with planting depth of 1/6 th of the height of the pole including digging of pits, disposal of extra earth, collection of boulders and filling back. 2 Erection of 13 mtr long Steel Tubular Pole with planting depth of 1/6 th of the height of the pole including digging of pits, disposal of extra earth, collection of boulders and filling back. 3 Erection of 11 mtr long Steel Tubular Pole with planting depth of 1/6 th of the height of the pole including digging of pits, disposal of extra earth, collection of boulders and filling back. 4 Erection of 9 mtr long Steel Tubular Pole with planting depth of 1/6 th of the height of the pole including digging of pits, disposal of extra earth, collection of boulders and filling back. 5 Erection of 13 mtr long PCC Pole with planting depth of 1/6 th of the height of the pole including digging of pits, disposal of extra earth, collection of boulders and filling back. 6 Erection of 11 mtr long PCC Pole with planting depth of 1/6 th of the height of the pole including digging of pits, disposal of extra earth, collection of boulders and filling back. 7 Erection of 9 mtr long PCC Pole with planting depth of 1/6 th of the height of the pole including digging of pits, disposal of extra earth, collection of boulders and filling back. 8 Painting of 16 mtr long Steel Tubular Poleincluding fixtures with one coat of red-oxide and two coats of silver(aluminium) paint 9 Painting of 13 mtr long Steel Tubular Poleincluding fixtures with one coat of red-oxide and two coats of silver(aluminium) paint 10 Painting of 11 mtr long Steel Tubular Poleincluding fixtures with one coat of red-oxide and two coats of silver(aluminium) paint 11 Painting of 09 mtr long Steel Tubular Poleincluding fixtures with one coat of red-oxide and two coats of silver(aluminium) paint 12 Cement Bottoming (U/G,A/G) in 1:3:6 mix including excavation and form work, (16/13/11/9 Mtr Long Poles (Complete Job) 13 Fixing of Galvanisedspiral Earthing of SWG No. 8,G.I wire of 115 turns confirming to REC-J1 construction standard, (J1) 14 Fixing of 66/33KV Galvanised Guy Set (Guy wire, Guy Rods, Turn Buckle plate ,Guy Insulators) confirming to IS 2141 / 1979 or the latest version thereof including digging of pits & refilling 15 Collection of Snapped ACSR Cond. and Re-stringing, tensioning , binding of ACSR Conductor, (100mm2 ACSR Conductor) 16 Collection of Snapped ACSR Cond. and Re-stringing, tensioning , binding of ACSR Conductor, (150mm2 ACSR Conductor) 17 Collection of Snapped ACSR Cond. and Re-stringing, tensioning , binding of ACSR Conductor, (200mm2 ACSR Conductor) 18 Dismantling of Steel Tubular Pole including carriage up to dumping site, (16 mtr. Long ) up to distance of 50 mtr 19 Dismantling of Steel Tubular Pole including carriage up to dumping site, (13 mtr. Long ) up to distance of 50 mtr 20 Dismantling of Steel Tubular Pole including carriage up to dumping site, (11 mtr. Long )up to distance of 50 mtr 21 Dismantling of PCC Pole including carriage up to dumping site, (11 mtr. Long )up to distance of 50 mtr 22 Dismantling of Steel Tubular Pole including carriage up to dumping site, (9 mtr. Long )up to distance of 50 mtr 23 Dismantling of PCC Pole including carriage up to dumping site, (9 mtr. Long )up to distance of 50 mtr 24 Dismantling of Three/Four pole structure, opening of channels, crossarms, angles(Complete Job.) 25 Dismantling of Two pole structure, opening of channels, crossarms, angles (Complete Job.) 26 Straightening of tilted Steel Tubular Pole (16 mtr. Long ) 27 Straightening of tilted Steel Tubular Pole (13 mtr. Long ) 28 Straighteningof tilted Steel Tubular Pole(11 mtr. Long ) 29 Straighteningof tilted PCC Pole(11 mtr. Long ) 30 Straighteningof tilted Steel Tubular Pole(9 mtr. Long ) 31 Straighteningof tilted PCC Pole(9 mtr. Long ) 32 Unloading of Steel Tubular Pole including carriage up to dumping site, (16 mtr. Long )up to distance of 50 mtr 33 Unloading of Steel Tubular Pole including carriage up to dumping site, (13 mtr. Long )up to distance of 50 mtr 34 Unloading of Steel Tubular Pole including carriage up to dumping site, (11 mtr. Long ) 35 Unloading of Steel Tubular Pole including carriage up to dumping site, (9 mtr. Long ) up to distance of 50 mtr 36 Loading of Steel Tubular Poles including carriage up to dumping site, (16 mtr. Long ) 37 Loading of Steel Tubular Poles including carriage up to dumping site, (13 mtr. Long ) 38 Loading of Steel Tubular Poles including carriage up to dumping site, (11 mtr. Long ) 39 Loading of Steel Tubular Poles including carriage up to dumping site, (9 mtr. Long ) 40 Extra carriage from dumping site, (16 mtr. Long )up to site of work Its 100 mtr 41 Extra carriage from dumping site, (13 mtr. Long )up to site of work Ist 100 mtr 42 Extra carriage from dumping site, (11 mtr. Long )up to site of work Ist 100 mtr 43 Extra carriage from dumping site, (9 mtr. Long )up to site of work Ist 100 mtr 44 Extra carriage of 9 Mtr PCC Pole beyond 100mtrs for every 50Mtr or part thereof in plain areas 45 Extra carriage of 11 Mtr PCC Polebeyond 100mtrs for every 50Mtr or part thereof in plain areas 46 Extra carriage of 9 Mtr PCC Pole beyond 100mtrs for every 50Mtr or part thereof in semi hillyareas 47 Extra carriage of 11 Mtr PCC Pole beyond 100mtrs for every 50Mtr or part thereof in semi hilly areas 48 Unloading of Steel of Sorts , (Steel) 49 Loading of Steel of Sorts , (Steel) 50 Unloadingof Conductor Reels, (100mm²/150mm²/200mm² ACSR Conductor)at site 51 Loadingof Conductor Reels, (100mm²/150mm²/200mm² ACSR Conductor) at site 52 Fixing of 33 kVDiscInsulator (70 KN)2008 standards, (Porcelain ) 53 Fixing of 33 kV Disc fitting (70 KN) 2008 standards, (Polymer) 54 Fixing of 33 kV Insulators (10 KN) standards, (Porcelain ) 55 Fixing of33 kV Pin Insulators (10 KN) suitable for 100/150/200mm² ACSR Conductor. 56 Replacement/Fixing of 33 kVTension fittings (Socket & Ball type or T&C Type) for ACSR 57 Replacement/Fixing of 33 kV Tension fittings (Socket & Ball type or T&C Type) for ACSR 150m² 58 Replacement/Fixing of 33 kVTension fittings (Socket & Ball type or T&C Type) for ACSR 200m² 59 Straighteningof X-arms of different sizes (100x50x50x6 mm channel Iron,50x50x6mm Angle Iron ) duly painted with one coat of red-oxide and two coats of silver paint fixing with different sizes and sorts of nuts,bolts and washers, (Channel Iron X-arms, Angle Iron-X-arms, Pole Tops) 60 Straighteningof angle ironof different sizes (65x65x6 mm channel Iron,50x50x6mm Angle Iron 61 Repair and re-erection of Cradle for guard netting with GI wire 8 No including wire binding, cutting /bending of GI Wireas per REC standards 62 Branch cutting of 33 kV lines 63 Removing of wild climbers/vegetation around 33 kv Poles 64 Removing of wild climbers/vegetation around 33 kV Tower 65 Removing of wild climbers from top of 33 kV Lines. 66 Removing of wild climbers from Peak, cage, cross arm of 33 kV old tower Line 67 Patrolling of 33 kV Line(Routine/Under fault) 68 Tightening of loose guys 69 Dismantling & re-erection of damaged guys including digging of pit & refilling the same 70 Replacement of damaged Disc insulator in tension string 71 Replacement of cross arms of sizes 100x50x6 72 Replacement of angle iron of sizes (65x65x6, 50x50x6) 73 Replacement of Pin insulator on Four/Three/Double Pole Structure 74 Replacement of Pin insulator on Single Pole Structure 75 Replacement of Worn-out/Damaged Jumper of 33 kV Towerlines 76 Replacement of Disc Insulator, Suspension Fitting of 633 kV Towerlines 77 Replacement of worn-out/Loose/Damaged Jumper of 33 kV lines (sets of3 Nos) 78 Local earthing of 33 kV Lines by way of using discharge/earth rods at faulty site to avoid accident due to any induction while working on Line. 79 Tightening / restringing of loose ACSR Dog 100 mm2 80 Tightening / restringing of loose ACSR Wolf 150 mm2 81 Tightening / restringing of loose ACSR Panther200 mm2 82 Dismantling & Re-erection of ACSR Dog 100mm2 including collection of dismantled conductor , making of small bundles and its carriage 83 Dismantling & Re-erection of ACSR Wolf 150mm2 including collection of dismantled conductor , making of small bundles and its carriage 84 Dismantling & Re-erection of ACSR panther 200mm2 including collection of dismantled conductor , making of small bundles and its carriage 85 Dismantling of stay sets complete 86 33 KV VCB Repairs & Renovationby way of a) Setting of Mechanical Assembly / Replacement of damaged spring / Repair of locking & charging system 87 b) Replacement of Tripping Coil/Closing coil 88 c) Replacement of Damaged Vacuum Interrupter 89 d) Replacement ofBushing including Clamps 90 33 kV C&R Panel: Replacement of different equipmentsa) Ammeter, Volt Meter Indication , Lamps, Fuses, Trip Close Switch ,Selector SwitchIdentification of Panel Wiring Faults & its rectification 91 b) Replacement of Different Relays - MITNumerical Relay / Electro-mechanical relay / Master Trip Relay/ Differential Relay/Auxiliary Relay etc. 92 Installation, Testing, commissioning of 66-33 kV Control Relay Panels (Complete Job) 93 Complete testing of Relays Setting of Testing Kit, Interconnection between various points of panel with respect tosecondary injection key on various current taps, recording the observation thereof. All modifications necessary to achieve desired results. 94 Control Cable Replacement of damagedControl Cables of all typesincluding binding with PVC Belts/ Binding Wire, Peeling of insulation and fixing of proper size thimble connecting the cable after identification of each core to both ends i.e. Panel to CTs / panel toPTs /panel to Breaker and Making functional of 33 KV Outdoor Breakers, Protection , Alarms, Annunciation (complete Job) 95 Upkeep of earthing of aux. transformer 96 Upkeep of earthing of Power transformer 97 Upkeep of earthing of 33/11 kV LA 98 Providing of extra earthing for improvement purpose (complete job) 99 Upkeep of earth mat of out door yard 100 Replacement of damaged earth mesh in Sub-Station as per approved Map & Design. 101 Excavation of trenches of 0.6 Mtr Depth and 2.0 Mtr wide mtr in normal soil / hard soil 102 Repairing / Laying of MS Flat and MS Rod in deep excavated trench and welding of MS Flat & MS Rod with Mesh. 103 Repairing of Earthing with Spikes of MS Rod 20mm, 3 Mtr in Length as per REC Drawing 104 33/11 KV Power Transformera) Opening of Transformer Tank Top Cover to prevent oil leakage from top(if required to facilitate maintenance of transformer after removing the required accessories), ,Draining/ Re-Filling of required Oil, Change of gaskets of valves/ radiators/ Buchholzs relay radiators valves of power transformer of capacity: 3.15 MVA to 10 MVA 105 b) Replacement of silica gel 106 c) General Inspection by through inspection of each individual parts, Ratio test by applying voltage on HV Side and measuring LV Voltage on various Tap Positions, checking of Buchholz relay, Surge relay conservator, sensors, measurement of 1R-Value dialectic strength of oil, cleaning of Power Transformer etc 107 d) Replacement of any one of the following i.e. temperature indicators, gas operated Buchholzs relay, oil temperature indicator, winding temperature indicator etc 108 e) Preventing of leakage by changing main gaskets after removing the old gasket, Replacement of HV/LV Busing & Bush Rod,Ring and Rubber Washers (complete job to prevent leakages) 109 f) Cleaning of Scale deposited over the body and radiators of the power transformer with thinner/ detergent and de-rusting in perfect manner.(routine work) 110 g) Cleaning of LV/HV bushings of Power Transformer(routine work) 111 h) Replacement of Bus Bars ofPower Transformer 112 i) Replacement of LV/HV clamps of Power Transformer 113 Oil Topping of Power Transformer 10 MVA 114 Oil Topping of Power Transformer 4 MVA to 6.3 MVA 115 Oil Topping of Power Transformer 3.15 MVA 116 Recording of IR values of transformers 117 Installation, Testing and Commissing of Power Transformer 66-33/11 KV Installation of LV/HV Bus Bars with proper care, of transformer for any leakagecommissioning of Power of Transformers by applying low voltageapproximately equal to impedance voltage on HV Side and short circuiting the LV terminals, Energizing the transformer by applying required primary voltage to it & keeping the transformer on no load to observe the behaviour of transformer, setting on 25% of the load on the transformer for a period of at test 6 hours and observation of oil including temperature, increase the transformer is fully loaded and topping of oil.a) 10 MVA 118 b) 6.3 MVA 119 c) upto 5 MVA 120 Checking and tightening of Jumpers, Droppers in 66/33 KV Outdoor Yard 121 Replacement of T/PG clamps 122 Replacement of Disc insulators including its hardware. 123 33 KV LA & 11 KV Stn. Type LAReplacement of 66 KV,33 KV & 11 KV Lightening Arrestor including jumpering and earth connecting in all respect. a) 66 KV LA 124 b) 33 KV LA 125 b) 11 KV LA 126 Separate pipe Earthing / G.I Rod earthingas per REC Drawing J.2 127 Replacement of pipe earthing / Rod earthing with new one 128 Installation, testing and Commissioning, replacement of 66 KV Isolators 129 Installation, testing and Commissioning,replacement of 33 KV Isolators 130 Replacement of11 KV Isolators 131 Repair & Renovationof 66/33 KV and 11 KV isolators including setting right its alignment for proper operation, lubrication/greasing of jaws, bearings operatings handle etc(complete job) 132 Replacement of worn-out/heated Pad clamp/Isolator clamps of 66/33/11 kV Isolator by way of dismantling. Drilling of holes on new and fixing (complete job) 133 Repair & Renovationof Isolator Jaws 66/33 KV and 11 KV isolators.(complete job) 134 Replacement of post insulator / tendon pipes/ operating box by way of dimentalling, necessary fabrication where ever required for proper operation of 66/33/11 kv Isolators. 135 33 KV CTsInstallation, testing and Commissioning of 33 kV CTs ( of all ratios )Complete Job 136 33 KV CTsRepairs & Renovation of 33 KV CTs by way of replacing shorting strips, connecting rod, transformer oil, damaged insulator (CTs of all ratios) 137 Replacement of 33 KV Outdoor Type CT of different ratio and dismantling of damaged CT(CTs of all ratios) 138 Oil Topping of 66/33 kV CT & PT by way of opening of top cover and refixing with new gaskets if necessary and preventing of oil leakages if any.(complete job) 139 66-33 kV PTsInstallation, testing and Commissioning of 66-33 kV PTs (complete job) 140 66 kV PTsReplacement of 66 KV Outdoor Type PT and dismantling of damaged PT, dragging to installation/loading site, lifting from ground to steel structure. 141 33 kV PTsReplacement of 66 KV Outdoor Type PT and dismantling of damaged PT, dragging to installation/loading site, lifting from ground to steel structure 142 Cleaning of porcelain bushing, tightening ofPT/CT clamps, derusting & painting of body of 33 kV PTs & CTs 143 Tightening of nuts & bolts, replacement of oval thread bolts, chipping by way of welding to the bolts after tightening in a single bay 144 Painting with mix red oxide paint two coats of approved make on steel works after cleaning with wire brush/ sand paper 145 Painting of steel structure erected in outdoor yard with aluminium paint two coats with approved brand andfixture to given an even surface 146 Battery Banka) Repair & maintenance of battery set including maintaining specific gravity, electrolyte level, cleaning, checking, tightening of battery terminals in all respects it includes measuring voltage of each battery. 147 b) Tightening of all nut and bolts, replacement of damaged battery cells 148 c) Installation, testing and Commissioning of Battery Bank (complete Job) 149 Battery ChargerRepair/Renovation battery charger for proper functioning by way of replacement of rectifier unit, Ammeter, Voltmeter, MCB,Cooling fan, LED indications, buzzer alarms for OV/UV etc (Complete Job) 150 Repair and maintenance of DC Board, identification of fault in respect of cableand its replacement, replacement of damaged MCCB, Kit Kat, Bus Bar & other allied job. 151 Repair and maintenance of AC Board, identification of fault in respect of cableand its replacement, replacement of damaged MCCB, Kit Kat, Bus Bar & other allied job. 152 Installation, testing and Commissioning of Battery Charger (complete Job) 153 Deweeding of vegetation in outdoor yardRemoving of stone metal, deweeding of unwanted vegetation, spreading of stone metal collected earlier for removal of vegetation, levelling the area with existing stone metal 154 Providing of additional stone metal and its carriage and laying in outdoor yard, this including breaking of stones complete job. 155 Cleaning of Control Room, removing dirt & dust from the panels, walls, cleaning of fixtures (for one bank) 156 Painting of internal/external walls and roof by approved brand of oil based distemper 157 Painting of door and window panels of control room by approved brand of paint 158 Repairs & Renovation of 11 KV VCB,by way of replacement of a) Grid-spout assembly 159 b)Replacement of damaged CTs of different ratio Testing the CT with the help of primary injection set fixing in pannel, fixing the secondary connection after assessing the load (complete job) 160 c)Thorough checking of control wiring circuits, replacement of damaged wire if any, replacement of terminal plates, tripping circuits, close/ trip switch, ammeter switch, replacement of voltmeter & ammeter . 161 d) Replacement of 11 KV damaged PT 162 e) Replacement of blown fuses, checking the PT terminal with respect of 11 KV bus bar complete job. 163 f) Replacement of Trip/Close coil 164 g) Replacement of Trivector meter on 11/33/66 kV Panels 165 Installation, testing and Commissioning , replacement of LT cabele 166 11 KV Power Cables / 33 KV Power cables/66 KV Power cablesa) Identification of damaged portion of cable, tracing of cable, remove cable from trench, carriage and laying of cable(complete job) including cleaning of cable trenches. 167 b) Replacement of damaged cable of sizes 168 Replacementof termination kits of different sizes, connecting the cable with panel and outgoing structures after crimping of lugs fixing with nuts and bolts, checking of earth point, connecting the earthing point of cable with existing earthing system a) 11 KV Indoor Termination Kit (1-Phase/ 3 phase) 169 b) 11 KV Outdoor Termination Kit (1-Phase/ 3 phase) 170 c) 33 KV Indoor Termination Kit (Single Phase) 171 d) 33 KV Outdoor Termination Kit (Three Phase) 172 e) 33 KV Indoor Termination Kit (Three Phase) 173 f) 33 KV Outdoor Termination Kit (Single Phase) 174 Improvement of earthing system in control room by way of replacement of earthing risers from earthing point to panel / checking of all welding points/ re-welding of lose connection, laying of fresh / additional earth-mat strip to improve the existing earthing system (Complete one Panel set) 175 Checking of IR values 176 De-watering of receiving station to avoid water logging. 177 Repairing of electrical circuits for improvement of control room immunination, power points etc (Complete Job) 178 Installation, Testing, commissiing for replacement of Aux. Transformer at receiving station 179 On site repairing of aux transformer for missing phase, LT strip, LT bush rod, LT bush cup, HT bush rod etc (Complete job) 180 Transport charges for carriage of T&P, men & material on urgent basis during power breakdown and restoration of system. (auto carrier) aditional 1km @ 90/per km 181 Replacement of out door yard lights including wiring system and fixing oflamps on fixtures. 182 Marking of equipments, sign boards by way of painting/fixing of PVC plates for demarcation of different equipment to avoid mishandling. 183 Replacement/repair/fixing of ceiling fans at Receiving station. 184 Replacement/repair/fixing of cooling fans on radiators of power transformer to avoid heating. 185 Flash in 66KV,33 KV & 11 KV Panels due to overloading moisture, Cleaning of carbonized panel by petrol / cotton cloth, replacement of damaged / worn-out lugs, post insulator, Bakelite sheet, arcing chamber panel heaters etc. 186 Repair of plaster of thickness 12 mm to 20 mm in patches of areas 2.5 sqm meters and under including cutting the patch in proper shape and preparing and plastering the surface of the walls complete incl. disposal of rubbish to the dumping ground within 50 M leada) with Cement mortar 1:4 (1 cement : 4 fine / coarse sand) 187 Cutting of large tree branches falling over 33/11 lines and coming into the corridor to avoid damages/ faults/conductor snapping. 188 Cleaning of cable duct, removing of duct covers and placing back after cleaning the duct including disposal of rubbish up to 50 Mtr lead 189 Replacing sand store slabs in roofing, laid incement mortar 1:4 (1 cement : 4 coarse sand) including necessary repairs and cement painting with same mortar complete, including disposal of rubbish to dumping ground within 50 Meters of lead 190 Dismantling doors, windows and clerestory windows (steel or wood) shutter including chow khats, holdfast etc. Complete and stacking with 50 Mtr lead 191 Providing and fixing T-iron frames for doors, windows and ventilators of mild steel T-sections, joints mitred and welded, including fixing of necessary but hinges and screws and applying a priming coat of approved steel primer (CC 1:3:6) 192 Demolishing cement concrete manually / by mechanical means including disposal of material within 50 Mtr 193 Cement concrete 1:2:4 (1 Cement : 2 Coarse Sand : 4 graded Stone aggregate)62 mm thick 194 Roof top treatment to prevent water leakage of control room 195 Repairing of receiving station mesh fencing / Chain link mesh fencing height upto 8ft 196 Watering of earth pits 197 Cleaning/washing of solar panels & batteries 198 Cleaning of ACDC,DBDC Board, RTCC, Charger, Battery Bank, Solar batteries, other alike small equipments (complete Job) 199 Cleaning of 33 kV CRP using vacuum cleaner from inside with proper care, from outside with thinner/varnish and making 33 kV CRP Vermic Proof. 200 Cleaning of 11 kV Panel using vacuum cleaner from inside with proper care, from outside with thinner/varnish and making it Vermic Proof to avoid rodent faults. 201 New 33 KV Line Fabrication , erection and painting of 15 Mtr long 33 KV Self supporting tower structure for crossing of road 202 Laying of foundation for 33 KV self supporting Tower Structure 15 Mrs. long including setting of stubs complete job 203 Erection of Channel cross arm of size 100X50X 6mm ,10 feet long and above including fixing of MS flat iron clamps with required size of bolts including punching of bolts complete 204 Erection of Channel cross arm of size 100X50X 6mm up to 09 feet long including fixing of ms flat clamps with required size of bolts including punching of bolts complete 205 Erection of Angle Iron Braces of size 65X65X6 mm,fixing with double clamp of MS Flat including punching of bolts of Ist level to level 3rd in cross section typeabove up to 14longcomplete 206 Erection of Angle Iron Braces of size 65X65X6 mm along with belts of same size ,fixing with double clamp of MS Flat including punching of bolts of Ist level to level 3rd in cross section type 6 and above upto 10longcomplete 207 Erection of Angle Iron belts of size 50X50X 6 mm along with belts of same size ,fixing with double clamp of MS Flat including punching of bolts of Ist level to level 3rd in cross section type upto 10 long 208 Erection of Angle Ironof size 65X65X6 mmfixing with double clamp of MS Flat including punching of bolts of Ist level to level 3rd in crossection typeabove11 long complete for guardnetting. 209 Flat iron ties 50x6 mm size 1 feet long along with fixing with cross arms 210 Erection of 33 KV Disc insulator (polymer type )with tension fittings including punching of locking pinscomplete 211 Erection of 33 KV Pin insulator with pins3 nos on top of cross arm including fixing of MS Flat Ties to rest it on , punching of base bolt /locking pin complete 212 Erection of Guy rodincluding digging of pit , Disposal of excavated soil ,refilling of excavated pits in layers of stone boulders and fine soil including fixing , adjusting properly Turn Buckle, Anchor Plate and staining screw complete 213 Carriage at site , un-bundling , Laying and stringing of ACSR DOG Conductor including making of small bundles of conductor as per site requirement, cutting in required span lengths complete (AS PER REC STANDARD) 214 Erection of anti climbing Devices at ST pole along with fixing /cutting /bending of Barbed wire, fixing with clamps 215 Erection of Danger plates 216 Route /temp path clearance by way of cleaning bushes and vegetation & making temp. pathcutting & filling for carriage of line material ( 400 mx1mx0.2m)= 80 cum 217 Watch and ward of the material and T&P round the clock i.e. 3 shifts, Rate of 1 Lab for 1 Shift 218 Route clearance for corridor of 5 m 219 Installation, testing and Commissioningof 3.15 MVA , 33/11KV Power Transformer (new work) 220 Installation, testing and Commissioning of 5 MVA& 6.3 MVA , 33/11 KV Power Transformer 221 Installation, testing and Commissioningof 10 MVA , 33/11KV Power Transformer 222 Installation, testing and Commissioning of 11kV Panel Borad with VCB Incomer(one no.) 223 Installation, testing and Commissioning of 11kV Panel Borad with VCB outgoing(one no.) 224 Setting of stubs with templates after positioning and leveling of templates excluding cost of foundations 225 Handling and Fabrication of Material in Divisional Store, Fabrication of Angle iron braces/belts /guard netting angles,fencing posts etc from angle iron of sizes 226 Fabrication of guy rods complete including turn buckle, staining screw, anchor plate, thereading of guys and staining screw 227 Fabrication of channel cross arms of sorts from MS channel of sizes , Making holes as per requirement,Punching of members and numbering on each member,Grinding of sharp edges and uneven surface of memebers and painting of members with red oxide paint. 228 Fabrication of ties, clampsfrom MS flat ( suitable for 9 mts, 11mts, and 13mts poles) 229 Fabrication of earthing plates , cable duct coversfrom MS plate as per REC drawings 230 Fabrication of earthing spikes from MS Tor steel of sorts as per REC drawings 231 Fabrication of ST poles by way of drilling of extra holes 232 Fabrication of foundation boltsfrom MS Tor steel of sorts including threading as per REC drawings 233 Fabrication of earthing pipe from GI pipe and welding of earthing plateas per REC drawings 234 Fabrication of column structures, beam structure, isolator structures,LA ,CT,PT and PI Structures as per REC drawings 235 Shifting of channel/Angle /Flat iron at and average distance of 50mtr from unloading site to site of stacking and stacked properly. 236 Shifting of channel/Angle /Flat iron/fabricated material at and average distance of 50mtr for making space for other store material and its stacking . 237 Unloading of ST poles 9mtr in divisional store 238 Unloading of ST poles 11mtrin divisional store 239 Unloading of ST poles 13mtrin divisional store 240 Unloading of ST poles 16mtrin divisional store 241 Unloading of PCC Poles 9/8 mtr . in divisional store 242 Unloading of PCC Poles 11 mtrin divisional store 243 Unloading of PCC Poles 13 mtr in divisional store 244 Dragging/shifting of PCC/ST Pole at and average istance upto 50 mtr for stacking to accesible place for loading/unloading purpose and its satacking 245 Unloading of ACSR Conductor dogin divisional store 246 Unloading of ACSR Conductor wolfin divisional store 247 Unloading of ACSR Conductor pantherin divisional store 248 Shifting of Old/New ACSR Conductor at and average distance of 50mtr for unloading site to site of stacking and stacked properlyand also for making space for other store material and its stacking .. 249 Unloading of 11KV VCB pannels (1+3) 250 Unloading of 11KV VCB pannels (1+4) . 251 Unloading of 11KV VCB pannels (1+5) . 252 Unloading of 11KV VCB pannels OK/Damage(1no) . 253 Unloading ofAC Board/DC Board/Battery bank/ Battery charger 254 Unloading of 33 VCB /C&R Pannel . 255 Shifting/ draggingof 11/33/66kv panel at an average distance of 50mtr for making space for other store material and its stacking also for making space for other store material and its stacking . 256 Unloading of XLPE Cable 120/185 mm² . 257 Unloading of XLPE Cable 240/300 mm² . 258 Unloading of XLPE Cable 400/630 mm² . 259 Shifting of XLPE Cable all sizes at an average distance of 50mtr from unloading site to site of stacking and stacked properly also for making space for other store material and its stacking ... 260 Unloading of 66/33/11 KV Cable kits of different sizes 261 Shifting of 66/33/11 Cable kits of all sizes at an average distance of 50mtr from unloading site to site of stacking and stacked properly also for making space for other store material and its stacking ... 262 Unloading of Guy/GI wire/Barbed wire including carriage towards stacking site and stacked porperly. 263 Unloading of Power Transformer 3.15/4 MVA New/damage . 264 Unloading of Power Transformer 5/6.3MVA New/damage . 265 Unloading of Power Transformer 10 MVA New/damage . 266 Unloading of 11KV New/damage DistributionTransformer. 267 Dragging of 3.15/4 MVA New/damage Transformer at an average distance upto 50 mtr for stacking to accesible place for loading/unloading purpose and its satacking 268 Dragging of 5/6.3 MVA New/damageTransformer at an average distance upto 50 mtr for stacking to accesible place for loading/unloading purpose and its satacking 269 Dragging of 10 MVA New/damage Transformer at an average distance upto 50 mtr for stacking to accesible place for loading/unloading purpose and its satacking 270 Dragging of 11kv Transformer at an average distance upto 50 mtr for stacking to accesible place for loading/unloading purpose and its satacking 271 Unloading ofTransformer oil Barrels. 272 Dragging ofTransformer oil old/ new barrel at an average distance upto 50 mtr for stacking to accesible place for loading/unloading purpose and its satacking also for making space for other store material and its stacking .. 273 Unloading ofMS Angle, MS Channel, MS flate ,tar steel 274 Unloading of hardware items such as nuts and bolts , clamps of sorts, washers,welding rods,old sarees,chain link mesh,pipe etc . 275 Shifting ofhardware items such as nuts and bolts , clamps of sorts, washers,welding rods,old sarees,chain link mesh,pipe etc at an average distance of 50mtr for making space for other store material and its stacking . 276 Unloading of 33/11 KV Dics insulators. 277 Unloading of 33 KV Dics fittings 278 Shiftingof 33/11KV disc insulator at an average distance upto 50 mtr for stacking to accesible place for loading/unloading purpose and its satackingalso for making space for other store material and its stacking .. . 279 Unloading of 33/11 KV Pin insulators/Guy insulator /G.I Pin. 280 Shiftingof 33/11KV pin insulator /guy/G.I Pinsat an average distance upto 50 mtr for stacking to accesible place for loading/unloading purpose and also for making space for other store material and its stacking. 281 Unloading of Cement. 282 Shiftingofcement/cement block at an average distance upto 50 mtr for stacking to accesible place for loading/unloading purpose and also for making space for other store material and its stacking ... 283 Unloading of 33 KV CT/PTUnit . 284 Shifting of 33 KV CT/PT at an average distance of 50mtr for making space for other store material and its stacking . 285 Unloading of 11 KV CT/PTUnit includingcarriage towards stacking site and stacked porperly. 286 Shiftingof 11 KV CT/PTat an average distance upto 50 mtr for stacking to accesible place for loading/unloading purpose and also for making space for other store material and its stacking .. 287 Unloading of 33 KV Isolators. 288 Shiftingof 33KV Issolatorsat an average distance upto 50 mtr for stacking to accesible place for loading/unloading purpose and its satackingand also for making space for other store material and its stacking . . 289 Unloading of 33/66 KV LAs. 290 Shiftingof 33/66KV LAsat an average distance upto 50 mtr for stacking to accesible place for loading/unloading purpose and also for making space for other store material and its stacking . 291 Unloading of 11 KV LAs/GO/HG/issolator . 292 Shiftingof 11 KV LAs/GO/HG/issolator at an average distance upto 50 mtr for stacking to accesible place for loading/unloading purpose and also for making space for other store material and its stacking .. 293 Unloading of PVC Cable /Control cable of different sizeincludingcarriage towards stacking site and stacked porperly. 294 Unloading of AL Paint /Red oxide paint/ Black paintincludingcarriage towards stacking site and stacked porperly. 295 Unloading of T&P Items like Drilling machine,chainPully ,Pully lifting machine ,Hand drill machine,AL ladder,welding set,tool kit,crimping tooletc 296 Unloading of Testing equipments like Meggar, Earth resitivitytester , Oil testing machine,Search Light, Turn ratio meter , multimeter etc . 297 Unloading of Safetyequipments like Safety belts, Safety shoes, Fire Extinguisher,Hand gloves, Yard lights , LED Bulbs , Rubber mat , etc 298 Shiftingof T&P /Testing / Safetyequipments at an average distance upto 50 mtr for stacking to accesible place for loading/unloading purpose and also for making space for other store material and its stacking .. 299 Unloading of Filter plant heavy duty 300 Shiftingof Filter plantat an average distance upto 50 mtr for stacking to accesible place for loading/unloading purpose and also for making space for other store material and its stacking . 301 Loading of PCC Poles 9/8 mtr 302 Loading of PCC Poles 11 mtr 303 Loading of PCC Poles 13 mtr 304 Loading of ST poles 9mtr 305 Loading of ST poles 11mtr 306 Loading of ST poles 13mtr 307 Loading of ST poles 16mtr 308 Loading of ACSR Conductor dog 309 Loading of ACSR Conductor wolf 310 Loading of ACSR Conductor panther 311 Loading of Cement 312 Loading of 11 KV VCB 1+3 Pannels 313 Loading of 11 KV VCB 1+4 Pannels 314 Loading of 11 KV VCB 1+5 Pannels 315 Loading of 11 KV VCB 1 Pannel OK/Damage 316 Loading of AC Board/ DC Board/Battery charger /Battery bank 317 Loading of 33KV VCB 318 Loading of 33KV C&R Pannels 319 Loading of XLPE Cable 120/185 mm² 320 Loading of XLPE Cable 240/300mm² 321 Loading of XLPE Cable 400/630 mm² 322 Loading of Cable kits of different sizes 323 Loading of Guy/GI wire/Barber wire 324 Loading of Power Transformer 3.15/4.0 MVA 325 Loading of Power Transformer 5.0/6.3 MVA 326 Loading of Power Transformer 10 MVA 327 Loading of 11 KV DistributionTransformer 328 Loading of Transformer Oil barrels 329 Loading of MS Angle iron braces, MS channel cross arms, Guy rod, Earthing spikes, MS Flate 330 Loading of hardware items such as nuts and bolts, clamps of sorts,washers,welding rods,old sarees,chain link mesh,pipe 331 Loading of 33 /11KV Disc insulator 332 Loading of 33 KV Disc fitting 333 Loading of 33/11 KV Pin insulator /Guy insulator /G.I Pin 334 Loading of 33 KV isolator 335 Loading of 33 KV LA 336 Loading of 11KV Isolators 337 Loading of PVC Cable /Control cable of different size includingcarriage from stacked site. 338 Loading ofAL Paint /Red oxide paint/ Black paint 339 Loading ofFilter plant heavy duty 340 Carriageof Fabrication column structures, beam structure, isolator structures,LA ,CT,PT and PI Structures etc towards stacking site and stacked properly 341 Loading ofFabrication column structures, beam structure, isolator structures,LA ,CT,PT and PI Structures etcincludingcarriage from stacked site. 342 Loading of 33 KV CT/PT units 343 Loading of 11 KV CT/PT units 344 Loading of T&P Items like Drilling machine,chainPully ,Pully lifting machine, Hand drill machine,AL ladder,welding set,tool kit,crimping tooletc units 345 Loading of Testing equipments like Meggar, Earth resitivitytester , Oil testing machine,Search Light, Turn ratio meter , multimeter etc units 346 Loading of Safetyequipments like Safety belts, Safety shoes, Fire Extinguisher,Hand gloves, Yard lights , LED Bulbs , Rubber mat , etcunits 347 Shifting of allied materials for making space for porper stacking of material 348 Carriageof Fabrication material from fabrication site towardsstacking site and proper stacking of material. 349 Repair of store shed by way of replacement of damaged CGI sheets, repair of CGI sheets by way of welding, replacememt of hooks, nuts and bolts, tightening of nuts bolts and hooks and welding . 350 Collection andcarriage of T&P items to working site and back crriage of T&P after job 351 Sorting of material by way of weighing / measuring and inspection of material and then carriage from weighing / measuring and inspection site to site of fabrication 352 painting of store shed with red oxide/Al paint single coat 353 Checking/Measuring/ Inspection/Meggering ofXLPE Cable/Control cable by way of unreal and after work agian rereelingon drum 354 Checking/Measuring/ Inspection ofACSR Conductorby way of unreal and after work agian rereelingon drum 355 Complete testing/ispection of pannels including relay testing , interconnection,charging polarity etc during issue/receipt/verification. 356 Prototype errection of Gantry /Beam/CT/PT/Isolator sturcture 357 Dismentling of ACSR Dog Conductor 358 Dismentling of ACSR Wolf Conductor 359 Dismentling of ACSR Panther Conductor 360 Dismentling of 3.15 MVA, 33/11 KV Power Transformer including dismentling of Cables, Radietors, drainage of Oil and filling in empty Barrels 361 Dismentling of 6.3 MVA, 33/11 KV Power Transformer including dismentling of Cables, Radietors, drainage of Oil and filling in empty Barrels 362 Dismentling of 10 MVA, 33/11 KV Power Transformer including dismentling of Cables, Radietors, drainage of Oil and filling in empty Barrels 363 Dismentling of 11 KV Panel Board with VCB (Incommer) 364 Dismentling of 11 KV Panel Board with VCB (Outgoing) 365 Installation of SMPS & CMR on Smart Meters 366 Installation/Replacement of Smart Meters
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 32
Jammu And Kashmir View Result →
18.
Power #9283810 Technical Bid
Supply Of Electrical And Store Hardware Items In Respect Of Stdi Jpdcl Jammu , 33 Kv & 11 Kv Cable Kits Indoor/Outdoor (Reputed Make Confirming To Relevant Is Specifications) A) Cable Kits 33 Kv Single Core Heat Shrinkable Indoor 630 Mm2 , B) Cable Kits 33 Kv Single Core Heat Shrinkable Indoor 300 Mm2 , C) Cable Kits 33 Kv Single Core Heat Shrinkable Outdoor 630 Mm2 , D) Cable Kits 33 Kv Single Core Heat Shrinkable Outdoor 300 Mm2 , E) Cable Kits 11 Kv Single Core Heat Shrinkable Indoor 630 Mm2 , F) Cable Kits 11 Kv Single Core Heat Shrinkable Outdoor 630 Mm2 , G) Cable Kits 11 Kv 3 Core Heat Shrinkable Indoor 400 Mm2 , H) Cable Kits 11 Kv 3 Core Heat Shrinkable Outdoor 400 Mm2 , I) Cable Kits 11 Kv 3 Core Heat Shrinkable Indoor 300 Mm2 , J) Cable Kits 11 Kv 3 Core Heat Shrinkable Outdoor 300 Mm2 , K) Cable Kits 11 Kv 3 Core Heat Shrinkable Indoor 240 Mm2 , L) Cable Kits 11 Kv 3 Core Heat Shrinkable Outdoor 240 Mm2 , M) Cable Kits 11 Kv 3 Core Heat Shrinkable Indoor 185 Mm2 , N) Cable Kits 11 Kv 3 Core Heat Shrinkable Outdoor 185 Mm2 , O) Cable Kits 11 Kv 3 Core Straight Through Joining Heat Shrinkable 185 Mm2 , P) Cable Kits 11 Kv 3 Core Straight Through Joining Heat Shrinkable 300 Mm2 , Q) Cable Kits 11 Kv 3 Core Straight Through Joining Heat Shrinkable 400 Mm2 , R) Cable Kits 11 Kv 3 Core Straight Through Joining Heat Shrinkable 630 Mm2 , S) Cable Kits 33 Kv Single Core Straight Through Joining Heat Shrinkable 630 Mm2 , T) Cable Kits 33 Kv Single Core Straight Through Joining Heat Shrinkable 300 Mm2 , U) Cable Kits 11 Kvindoor 120 Mm2 , V) Cable Kits 11 Kvoutdoor 120 Mm2 , W) Cable Kits 33 Kv Indoor 120 Mm2 , X) Cable Kits 33 Kvoutdoor 120 Mm2 , Tripping Coil 36 Volt Dc For 33/11 Kv Ocb / Vcb Panel , Tripping Coil With Plunger , 11 Kv Pt Fuse , 11 Kv Cts Of Different Ratios, Make Mei/ Bicco Lawrie / Crompton Greaves / Bhel/ Er/ Ssg/ Alstom For 11 Kv Ocb/ Vcb Panels/ Schinder/Stelmec/Megawin/Yamuna/Electric Field , I) 800/400/5-5 , Ii)750/375/5-5 , Iii)600/300/5-5 , Iv)400/200/5-5 , V) 300/150/5-5 , Vi)150/75/5-5 , Spares For Power Transformers A) Breather For 6.3 Mva 33/11 Kv Transformer (2 Kg) Ith Silica Gel , B) Breather For 3.15 Mva 33/11 Kv Transformer (2 Kg) With Silica Gel , C) Breather For 10 Mva 33/11 Kv Transformer (3 Kg) Ith Silica Gel , D) 20 Mm Lt Bush Rod For 33/11 Kv Transformer , E) 12 Mm Lt Bush Rod For 33/11 Kv Transformer , F) Metalic Clamp 20 Mm For Power Transformer , 33 Kv Bush For 10 Mva , 33 Kv Bush For 6.3 Mva , 33 Kv Bush For 3.15 Mva , Lv Bush For 10 Mva , Lv Bush For 6.3 Mva , Lv Bush For 3.15 Mva , F) Power Transformer Bush Clamp 20 Mm , G) Silica Gel , Relays A) Numerical Relay 3-Pole (24-50 V) 2 O/C And 1 E/F Relay (Ashida Adr-241A) , Relays B) Numerical Relay 3-Pole (24-50 V) 2 O/C And 1 E/F Relay (Siemens 7Sr: 2103) , C) Master Trip Relay 24-50 V Ashida Make Or Alstom Make , D) Master Trip Relay Ashida (Make) 18-52 (V) , E) Auxiliary Relay 3 Element (Ashida) , F) Auxiliary Relay 3 Element (Alstom) , Relay Compatible For Voltage Level 30 Volts , Relay Compatible For Voltage Level 36 Volts , 33 Kv Pin Insulator Make Iec, Bhel, Rastriya, Top Line, Tcpl Or Any Other Reputed Make Conforming To Relevant Is Specification , Epoxy Post Insulator , Epoxy Vaccum Interrupter Chamber For 11 Kv Vcb , Drive Insulator , 33 Kv Disc Insulator (B & S Type) 70 Kn Make Iec, Bhel, Rastriya, Top Line, Tcpl Or Any Other Reputed Make Conforming To Relevant Is Specification , 33 Kv Guy Insulator , 33 Kv Tension Fittings For Acsr Dog Conductor, B&S 3 U-Bolts Type , 33 Kv Tension Fittings For Acsr Wolfconductor, B&S 4 U-Bolts Type , 33 Kv Tension Fittings For Acsr Panther Conductor, B&S 4 U-Bolts Type , Tension Fittings For Acsr Dog Conductor, T&C Type , Tension Fittings For Acsr Wolfconductor, T&Ctype , Tension Fittings For Acsr Panther Conductor, T&C Type , Suspension Fittings For Acsr Dog Conductor, T&C Type , Suspension Fittings For Acsr Wolfconductor, T&Ctype , Suspension Fittings For Acsr Panther Conductor, T&C Type , Hardware & Clamps For Conductor 33 Kv Isolator Clamps For Acsr Dog Conductor , 33 Kv Isolator Clamps For Acsr Wolf Conductor , 33 Kv Isolator Clamps For Acsr Panther Conductor , 33 Kv Pt Clamps For Acsr Panther , 33 Kv Pt Clamps For Acsr Wolf , 33 Kv Ct Clamps For Acsrpanther , 33 Kv Ct Clamps For Acsrwolf , 33 Kv La Clamp For Acsr Panther , 33 Kv La Clamp For Acsr Wolf , T-Clamps For Acsr Panther Conductor (Heavy Duty) , T-Clamps For Acsr Wolf Conductor (Heavy Duty) , Pg Clamps For Panther Conductor (Heavy Duty) , Pg Clamps For Wolf Conductor (Heavy Duty) 2/12, 2.5/12 , Nuts & Bolts 4/8, 5/8 & 6/8 Dia Of Different Lengths (Full Threaded) , Galvanised Nut & Bolts , Aluminium Thimble 185Mm2 , Aluminium Thimble 240Mm2 , Aluminium Thimble 300Mm2 , Aluminium Thimble 400Mm2 , Aluminium Thimble 630Mm2 , Paints (Make Asian, Burger, Nerolac Or Any Other Reputed Make Conforming To Relevant Is Specifications) A) Aluminium Paint , B) Red Oxide Paint , C) Black Paint , M-Seal , Welding Rod 3.5 / 4 Mm (Electrode) , Pvc Tape , Ht Tape (Adhesive) , Para Plast Compound , Guy Wire 7/16 , G.I. Wire Of Sorts , Manilla Rope 1 Inch Thick , P.P. Rope 1 Inch Thick , Emergency Lights , Search Light / Dragon Light With In Built Charging System , Safety Belts Of Standard Quality , Safety Helmets Of Standard Quality , Safety Shoes Of Standard Quality , Megger 5000 V , Tool Kit Complete , Drill Bit 18/20/25Mm , I/C Switch 200 Amp , Fire Extinguisher For Electrical Sub Stations Of Relevant Is Specifications , A. Co2 (4.5 Kg) , B) Powder Based (Abc Type) 4 Kg , C) Powder Based (Abc Type) 6 Kg , D) Powder Based (Abc Type) 9 Kg , Fire Bucket With Stand , Anti Climbing Device , Insulation Rubber Mat (1 M X 2M) X 12Mm Thick , Hand Gloves 33 Kv Pair , 11 Kv Isolator With Earthing Blade 630 Amp (Polymer) , 11 Kv Isolator Without Earthing Blade 630 Amp (Polymer) , 11 Kv Horn Gap Set. , 11 Kv Link Set. , 11 Kv D.O. Set. , 33 Kv Isolator With Earthing Blade 1200 Amp (Polymer) , 33 Kv Isolator Without Earthing Blade 1200 Amp (Polymer) , 11 Kv G.O Set. , A) 36 Volts Battery Bank 100 Ah, 2 V, 18 No. Cellscomplete With All Accessories , B) Maintenance Free 36 V Lead Acid Battery (Vrla) Bank Comprising Of 18 No. Of 2 Volt Cells Of 100 Ah Capacity , C) 2 V Battery Cells (Lead Acid Battery Cell) , D) 2 V Battery Cells (Dry Battery Cell) , 30 Amp Manually Operated Battery Charger. , 30 V Battery Charger Automatic (Float & Boost) Compatible For Vrla Batteries , 30 Volt, Dc Distribution Board Indoor Type, Floor Mounted Made Out Of 14/16 Swg Crc Sheet, Dust, Vermin Proof, Duly Powder Coated And Wired As Per Standard Engineering Practice , Ac Distribution Board Indoor Type, Floor Mounted Made Out Of 14/16 Swg Crc Sheet, Dust, Vermin Proof, Duly Powder Coated And Wired As Per Standard Engineering Practice , Lightening Arrestors A) 11 Kv L.A. Set. (Station Type) (Polymer) , B) 33 Kv L.A. Set. (Station Type) (Polymer) , Control Cable A) 2.5 Mm2 Cu 2-Core , B) 2.5 Mm2 Cu 4-Core , C) 2.5 Mm2 Cu 8-Core , D) 2.5 Mm2 Cu 12-Core , Post Insulator A) 22 Kv Post Insulators(Polymer) , B) 33 Kv Post Insulators(Polymer) , 33Kv Disc Insulators (Polymer) , 33Kv Pin Insulators For Panther (Polymer) , 33Kv Pin Insulators Forwolf (Polymer) , 33Kv Pin Insulators For Dog (Polymer) , 11 Kv Vacuum Interupter Bottle A) G.E.C. , B) Crompton Greaves , C) Allind , D) Alstrom , E) Bhel , F) Schneider , G) Stelmec , H) Yamuna , I) Megawin , H.T. Tape , 33 Kv Single Core Xlpe Cable 630 Mm2 , 11 Kv 3-Core Xlpe Cable 400 Mm2 , 11 Kv 3-Core Xlpe Cable 300 Mm2 , 11 Kv 3-Core Xlpe Cable 240 Mm2 , 11 Kv 3-Core Xlpe Cable 185 Mm2 , Twin Core 16 Mm2 Pvc Cable (Al) , 11 Kv Xlpe Cable 120Mm 3- Core , G.I. Strip 25X3 Mm , Al Strip 25X3 Mm , Pvc Cable 3.5 Core Armoured X35 Sqmm , Copper Bus Bar Of Different Sizes , 33 Kv D.O Set. , Chain Link Mesh 6 , Chain Link Mesh 8 , Pannel Heater , Pcc Pole 11 Mtrs , Pcc Pole 9 Mtr. , St Pole 16 Mtrs , St Pole 13 Mtrs , St Pole 11 Mtrs , St Pole 9 Mtr , G.I Pipe 25Mm , G.I Pipe 40Mm , 11 Kv Link Set. , L.T Cable 3.5 Core 50 Mm2 , Barbed Wire , Exhaust Fan Heavy Duty 18 Of Reputed Make , Single Pulley , Yard Light (Led) 100 Watts , Yard Light (Led) 250 Watts , Alumunium Bus Bar , G.I. Plate , Ms Plate , Danger Plate 33Kv/11Kv , 33 Kv La Porcelain , Oil Tempature Meter (Oti) , Winding Temprature Meter (Wti) , 11 Kv Pt Set. (11 Kv/110 Volt) , Spring Charge Motor For 11 Kv Vcb Make Delco) Or Reputed Is Specifications) , Hrc Fuse 2 Amps/4 Amps/6 Amps For 11 Kv Pt , Digital Ampps Meter For 11 Kv Panel , Digital Clamp Meter , Voltmeter For 11 Kv Panel , Aluminum Ladder , Come Along Clamps For Acsr Dog , Come Along Clamps For Acsr Wolf , Come Along Clamps For Acsr Panther , Automatic Power Factor Regulator Single Ct Sensing, For Step, 90-550 V, 1/5 Amps, 50Hz , 11Kv Xlpe Cable Single Core 400Mm2 , Cable Kit 11 Kv Single Core 400Mm2 Indoor , Cable Kit 11 Kv Single Core 400Mm2 Outdoor , Pvc Cu. Wire 1.5Mm2 , Pvc Cu. Wire 2.5Mm2 , Pvc Cu. Wire 4Mm2 , Pvc Cu. Wire 6Mm2 , Ms Channel/ Angle/ Flat , 11 Kv Pin Insulator , 11 Kv Disc Insulators , 11 Kv Dis Fitting , 12V Lead Acid Battery 100Ah , Control Cable A.2.5Mm2 Cu 3-Core , B.2.5Mm2 Cu 6-Core , C.2.5Mm2 Cu 7-Core , D.2.5Mm2 Cu 10-Core , Lt Cable 31/2 Core 50Mm2 , Earthing Road (Gi)25Mm , Guy Rod Complete With T/B , 33 Kv Single Core Xlpe Cable 400 Mm2 , 33 Kv Single Core Xlpe Cable 300 Mm2 , 33 Kv 3-Core Xlpe Cable 300 Mm2 , 33 Kv 3-Core Xlpe Cable Kit 300 Mm2 Outdoor , 33 Kv 3-Core Xlpe Cable Kit 300 Mm2 Indoor , 33 Kv 3-Core Jointing Kit 300Mm2 , 33 Kv Single Core Xlpe Cable Kit 400 Mm2 Outdoor , 33 Kv Single Core Xlpe Cable Kit 400 Mm2 Indoor , 33 Kv Single Core Jointing Kit 400Mm2 , Copper Strip 25X3 , G.I.Pipe 50Mm 20 Long , Transformer Oil , Battery Charger 36 V , Foundation Bolt , Cement Bag , 33 Kv Ct , Led Strig Light 15M Long For Illumiunation , Mid Span Joiting Sleeves (Aluminum) For Panther , Mid Span Joiting Sleeves (Aluminum) For Wolf , Mid Span Joiting Sleeves (Aluminum) For Dog , Led Bulb 9W , Led Bulb 12W , Led Tuble Light , Led Bulb 25W , Acsr Dog Conductor , Acsr Wolf Conductor , Acsr Panther Conductor , Ceiling Fan , Pulling & Lift Machine (5-7 Ton Capacity) , Plier (Taparia, Knipex Stanley) , Tyre For Canter Truck (8.25-16) , Tyre For Truck (10.00-20) , Crimping Tool 630M2 , Chain Saw 22 Blade , Cgi Sheets 10 Long , Cgi Sheets 12 Long , Gi Roofing Sheet 10 Long , Gi Roofing Sheet 12 Long , Arcing Horns , Submersible Pump Motor For Borewell (3.0 Hp Single Phase) , Earthing Tester (Tong Type) , Discharge Rods , Earthing Electrode
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 4
Jammu And Kashmir View Result →
19.
Power #9231122 Technical Bid
Construction Of 220Kv Gis Substation, Sector-75A, Gurugram -- 1 220kV SystemThe 245kV SF6 gas insulated switch gear for three phase system shall have double bus bar arrangement with 7 bays (2 No. 100MVA 220/33kV transformer bay, 1 no. bus-coupler and 4 nos. feeder bays). Space for future 1 No. transformer bay and 2 No. Line bays and jointing plugs shall be kept in GIS hall for adding future bays and jointing plugs required for connecting GIS of different makes. The SF6 gas insulated switch gear rated for 220kV, 3-phase, 50 HZ 50kA fault level shall be of the indoor metal-enclosed type, comprising of following items.245kV, 2000A, single 3 – ⏀ or three 1 –⏀SF6 gas insulated, metal enclosed Bus bar arrangement, consisting of 2000Asingle 3 – ⏀or three 1 – ⏀ SF6 gas insulated switchgears, each Bus Bar comprising of:-i) Bus bar enclosures running the length of the switchgear to interconnect each of the circuit breaker bay modules in double main bus system.ii) Three, 2-core, single phase or single 3 – ⏀ ,2 core each phasevoltage transformers/ PTs.iii) 2000A, One 3 – ⏀or three 1 –⏀ , single pole, group operated isolator/disconnector with one, 3 – ⏀or three 1 –⏀, single pole, group operated earthing switch with manual and motor driven operating mechanisms.iv) 2000A, One high speed 3 – ⏀or three 1–⏀ , single pole, group operated earthing switches, complete with manual and motor driven operating mechanisms.v) Each GIS compartment with gas monitoring device, pressure switch etc. as required.vi) Terminal boxes/ Local Control Cubicle.vii) Interconnecting wiring/ piping.viii) Grounding, support structures and platforms. 2 245kV, 2000A, single 3 – ⏀or three 1 –⏀ , Bus coupler bay module, consisting of 2000Asingle 3 – ⏀or three 1 –⏀SF6 gas insulated switchgears, comprising of:i) 2000A, One 3 – ⏀or three 1 – ⏀ , SF6 gas insulated circuit breaker, complete with operating mechanism.ii) Three, 5-core, single phase current transformers (1200-800-400/1-1-1-1-1A)iii) 2000A, Two sets of single pole, group operated isolator/disconnector switches each with single pole, group operated earthing switch and complete with manual and motor driven operating mechanisms.iv) Each GIS compartment with gas monitoring device, pressure switch etc. as required.v) Terminal boxes/ Local Control Cubicle.vi) Interconnecting wiring/ piping.vii)Grounding, support structures and platforms. 3 245kV, 1250A, single 3 – ⏀or three 1 –⏀ , Transformer feeder circuit breaker bay module,consisting of 1250Asingle 3 – ⏀or three 1 – ⏀SF6 gas insulated switchgears, for transformer, each comprising of:-i) 1250A, One 3 – ⏀or three 1 –⏀ , SF6 gas insulated circuit breaker, complete with operating Mechanism.ii) Three, 5-core, single phase current transformers (450-300/0.577-1-1-1-1A)iii) 1250A, One 3 – ⏀or three 1 –⏀ , single pole, group operated isolator/disconnector without earthing switch, complete with manual and motor driven operating mechanisms.iv) 1250A, One 3 – ⏀or three 1 –⏀ , single pole, group operated isolator/disconnector with one 3 – ⏀or three 1 –⏀ , single pole, group operated earthing switch, complete with manual and motor driven operating mechanisms.v) 1250A, One 3 – ⏀or three 1 –⏀ , single pole, group operated isolator/disconnector with two earthing switches each comprising of one 3 – ⏀or three 1 – ⏀ , single pole, group operated earthing switches complete with manual and motor driven operating mechanisms.vi) Each GIS compartment with gas monitoring device, pressure switch etc. as required.vii)Terminal boxes/ Local Control Cubicle.viii) Interconnecting wiring/ piping.ix) Grounding, support structures and platforms. 4 245kV, 1250A, single 3 – ⏀or three 1 –⏀ , Transmission line feeder circuit breaker bay modules, consisting of 1250Asingle 3 – ⏀or three 1 –⏀SF6 gas insulated switchgears, each comprising of:-i) 1250A, One 3 – ⏀or three 1 – ⏀ , SF6 insulated circuit breaker, complete with operating mechanism.ii) Three, 5- core, single phase current transformers (1200-800-400/1-1-1-1-1A)iii) 1250A, One 3 – ⏀or three 1 – ⏀ , single pole, group operated isolator/disconnector without earthing switch, complete with manual and motor driven operating mechanisms.iv) 1250A, One 3 – ⏀or three 1 – ⏀ , single pole, group operated isolator/disconnector with one, 3 – ⏀or three 1 – ⏀ , single pole, group operated earthing switch, complete with manual and motor driven operating mechanisms.v) 1250A, One 3 – ⏀or three 1 – ⏀ , single pole, group operated isolator/disconnector with one normal and one high speed 3 – ⏀or three 1 – ⏀ , single pole, group operated earthing switches, complete with manual and motor driven operating mechanisms.vi) Each GIS compartment with gas monitoring device, pressure switch etc. as required.vii)Terminal boxes/ Local Control Cubicle.viii) Interconnecting wiring/ piping.ix)Grounding, support structures and platforms. 5 a) 220kV XLPE Copper cables (4X1CX400mm2) to connect 220kV side of 100MVA Transformer with GIS(approx.) 6 b) Termination kit at both ends for 220kV XLPE Copper cables (1CX400mm2). (Termination Kit for (GIS/AIS) both ends along with all accessories constitute a set for each cable) 7 a) 220kV XLPE Copper cables (4X1CX1000mm2) to connect 220kV transmission line feeders with GIS (approx.) 8 b) Termination kit at both ends for 220kV XLPE Copper cables (1CX1000mm2) (Termination Kit for (GIS/AIS) both ends along with all accessories constitute a set for each cable) 9 Ventilation system (AHU) to accommodate in designated room in GIS hall as per Annexure-V as it is already an integral part of the ventilation system 10 33kV SystemThe 36kV SF6 Gas Insulated Switchgear for three phase system shall have single bus bar arrangement with 26 bays (4 No. Transformer I/C bays from two 100MVA Transformers, 2 No. bus-sectionalizer bays, 16 nos. feeder bays, 2 No. T/F bays for Auxiliary Supply and 2 No. Capacitor bank bays). Space for 12 Nos. future bays (2 No. I/C of 220/33kV T/F bay, 8 No. line bays and 1 No. capacitor bank, 1 No. bus-sectionalizer bay for future) shall be kept in GIS hall for adding future bays and jointing plugs required for connecting GIS of different makes. The SF6 Gas Insulated Switchgear rated for 33kV, 3-phase, 50Hz, 31.5kA for 3 sec. fault level shall be of the indoor metal-enclosed type, comprising of following items. 36kV, 2000A,single 3 – ⏀ or three 1 –⏀, SF6 gas insulated, metal enclosed bus bars arrangement, consisting of 2000Asingle 3 – ⏀ or three 1 –⏀ SF6 gas insulated switchgears, each Bus Bar comprising of (single bus for each T/F with bus sectionaliser) :- i) Bus bar enclosures running through the length of the switchgear to interconnect each of the circuit breaker bay modules in single bus system.ii) Each GIS compartment with gas monitoring device, pressure switch etc. as required.iii) Terminal boxes/ Local Control Cubicle consisting of all protection relays, mechanism control system, indication system etc.iv) Interconnecting wiring/ piping.v) Grounding, support structures and platforms. 11 36kV, 2000A,single 3 – ⏀ or three 1 –⏀, SF6 gas insulated, metal enclosed bus sectionaliser, consisting of 2000Asingle 3 – ⏀ or three 1 –⏀ SF6 gas insulated switchgears, each Bus Sectionaliser comprising of :(1 for each T/F) i) 2000A, One 3 – ⏀ or three 1 – ⏀, SF6 gas insulated vaccum circuit breaker, complete with operating mechanism for sectionaliser bay.ii) Three, single-core, single phase current transformers (2000-1000/5A)iii) Two sets of 2000A, two 3 – ⏀ or three 1 – ⏀, single pole, group operated isolator/disconnector with one, 3 – ⏀ or three 1 – ⏀, single pole, group operated earthing switch, complete with manual and motor driven operating mechanisms.iv) Two sets of Three, 2-core, single phase or single 3 – ⏀, 2 corevoltage transformers/ PTs.v) Two sets of 2000A, One 3 – ⏀ or three 1 – ⏀, single pole, group operated isolator/disconnector with one, 3 – ⏀ or three 1 – ⏀, single pole, group operated earthing switch with manual and motor driven operating mechanisms.vi) Two sets of 2000A, high speed 3 –  or three 1 – , single pole, group operated earthing switches, complete with manual and motor driven operating mechanisms.vii) Each GIS compartment with gas monitoring device, pressure switch etc. as required.viii) Terminal boxes/ Local Control Cubicle consisting of all protection relays, mechanism control system, indication system etc.ix) Interconnecting wiring/ piping.x) Grounding, support structures and platforms 12 36kV, 2000A, single 3 – ⏀ or three 1 –⏀, Incomer transformer bay modules, consisting of 2000Asingle 3 – ⏀ or three 1 –⏀ SF6 gas insulated switchgears, for 100MVA, 220/33kV transformers, each comprising of: - (2 for each T/F) i) 2000A, One 3 – ⏀ or three 1 – ⏀, SF6 gas insulated vaccum circuit breaker, complete with operating mechanism for incomer bay from 220/33kV transformer.ii) Three, 4-core, single phase current transformers (2000-1000/0.577-5-5-1A)iii) 2000A, Two 3 – ⏀ or three 1 – ⏀, single pole, group operated isolator/disconnector with one, 3 – ⏀ or three 1 – ⏀, single pole, group operated earthing switch, complete with manual and motor driven operating mechanisms.iv)2000A, One 3 – ⏀ or three 1 – ⏀, single pole, group operated isolator/disconnector with two earthing switches each comprising of one 3 – ⏀ or three 1 – ⏀, single pole, group operated earthing switches complete with manual and motor driven operating mechanisms.v) Each GIS compartment with gas monitoring device, pressure switch etc. as required.vi) Terminal boxes/ Local Control Cubicle consisting of all protection relays, mechanism control system, indication system etc..vii) Interconnecting wiring/ piping.viii)Grounding, support structures and platforms.ix) Set of Surge Arrestors & Voltage Detectors 13 36kV, 630A, single 3 – ⏀ or three 1 –⏀, Transmission line feeder circuit breaker bay modules, consisting of 630Asingle 3 – ⏀ or three 1 –⏀ SF6 gas insulated switchgears, each comprising of:- (8 for each T/F) i) 630A, One 3 – ⏀ or three 1 –⏀, SF6 gas insulated vaccum circuit breaker, complete with operating mechanism for outgoing feeder.ii) Three, 3-core, single phase current transformers (600-300/5-1A)iii) 630A, One 3 – ⏀ or three 1 – ⏀, single pole, group operated isolator/disconnector with one, 3 – ⏀ or three 1 – ⏀, single pole, group operated earthing switch, complete with manual and motor driven operating mechanisms.iv) 630A, One 3 – ⏀ or three 1 – ⏀, single pole, group operated isolator/disconnector with one normal and one high speed fault make 3 – ⏀ or three 1 – ⏀, single pole, group operated earthing switches, complete with manual and motor driven operating mechanisms.v) Each GIS compartment with gas monitoring device, pressure switch etc. as required.vi) Terminal boxes/ Local Control Cubicle consisting of all protection relays, mechanism control system, indication system etc.vii) Interconnecting wiring/ piping.viii) Grounding, support structures and platforms.ix) Set of Surge Arrestors & Voltage Detectors 14 36 kV, 630A, 31.5 kA for 3 sec, SF6 gas insulated Capacitor Bay Modules, consisting of 630A single 3 – ⏀ or three 1 –⏀, SF6 gas insulated switchgears, each comprising of:- (1 for each T/F)i) 630A, One 3 – ⏀ or three 1 –⏀, SF6 gas insulated vaccum circuit breaker, complete with operating mechanism for outgoing feeder.ii) Three, 3-core, single phase current transformers(400-300/5-5A)iii)630A, One 3 – ⏀ or three 1 – ⏀, single pole, group operated isolator/disconnector with one, 3 – ⏀ or three 1 – ⏀, single pole, group operated earthing switch, complete with manual and motor driven operating mechanisms.iv) 630A, One 3 – ⏀ or three 1 – ⏀, single pole, group operated isolator/disconnector with one normal and one high speed fault make 3 – ⏀ or three 1 – ⏀, single pole, group operated earthing switches, complete with manual and motor driven operating mechanisms.v) Each GIS compartment with gas monitoring device, pressure switch etc. as required.vi) Terminal boxes/ Local Control Cubicle consisting of all protection relays, mechanism control system, indication system etc.vii) Interconnecting wiring/ piping.viii) Grounding, support structures and platforms.ix) Set of Surge Arrestors & Voltage Detectors 15 36 kV, 630A, 31.5 kA for 3 sec, SF6 gas insulated S/Stn Transformer Bay Modules, consisting of 630A single 3 – ⏀ or three 1 –⏀, SF6 gas insulated switchgears, each comprising of:- (1 for each T/F) i) 630A, One 3 – ⏀ or three 1 –⏀, SF6 gas insulated vaccum circuit breaker, complete with operating mechanism for outgoing feeder.ii) Three, single phase 2-core current transformers (60-30/5-1A)iii) 630A, One 3 – ⏀ or three 1 – ⏀, single pole, group operated isolator/disconnector with one, 3 – ⏀ or three 1 – ⏀, single pole, group operated earthing switch, complete with manual and motor driven operating mechanisms.iv) 630A, One 3 – ⏀ or three 1 – ⏀, single pole, group operated isolator/disconnector with two earthing switches each comprising of one 3 – ⏀ or three 1 – ⏀, single pole, group operated earthing switches complete with manual and motor driven operating mechanisms.v) Each GIS compartment with gas monitoring device, pressure switch etc. as required.vi)Terminal boxes/ Local Control Cubicle consisting of all protection relays, mechanism control system, indication system etc.vii) Interconnecting wiring/ piping.viii) Grounding, support structures and platforms.ix) Set of Surge Arrestors & Voltage Detectors 16 33kV XLPE copper Cable (6X1Cx1000mm2) for connecting 33kV side of each I/C of 220/33kV transformer with GIS. (Two cables shall be used in each phase for each I/C, i.e. 2 Runs per phase x 3 no. Phase x 4 no. I/C) (approx.) 17 Single phase Termination kit for both end for 33kV XLPE copper Cable (1cx1000mm2)(Termination Kit for (GIS/AIS) both ends along with all accessories constitute a set for each cable) 18 33kV XLPE copper Cable (3cx300m2) for connecting 33kV capacitor bank bay(approx.) 19 Three phase Termination kit for both end for 33kV XLPE copper Cable (3cx300mm2) (Termination Kit for (GIS/AIS) both ends along with all accessories constitute a set for each cable) 20 33kV XLPE copper Cable (3cx95mm2) for single ckt. for station transformer(approx.) 21 Three Phase Termination kit for both end for 33kV XLPE copper Cable (3cx95mm2)(Termination Kit for (GIS/AIS) both ends along with all accessories constitute a set for each cable) 22 100 MVA 220/33 kV Power T/F along with10% extra T/F oil 23 NIFPES for 220/33 kV Power T/F 24 220 kV Surge Arrestor 25 33 kV Surge Arrestor (Including Capacitor Bank) 26 220 kV NCT (450-300/1A) 27 33 kV NCT For 220/33kV T/F (2000-1000/5A) 28 220 kV CVT For Line 29 220kV C&R Panels with SASCkt breaker control Panel with auto reclose & line Protection Panel 30 Ckt breaker control Panel without auto reclose and Transformer protection panel (for both HV & LV side of 220/33kV T/F)(each T/F have 2 no. 33kV Incomer) (1 No. for each T/F) 31 Ckt breaker control Panel without auto reclose and Bus Coupler cum Bus Bar Protection panel (Double Bus bar ) 32 Time synchronizationequipment 33 1 X 21.744 MVAR 33 kV rating Capacitor Bank along with Str. & allied equipments ( NCTs Series Reactor etc.) as perspecification 34 33 kV Line and Earth switch for Cap Bank (630 Amp.) 35 220V 200 AH Tubular Type Lead Acid San Container Battery 36 220 V 200 AH SMPS Battery charger 37 220 V D.C.D.B. 38 415 V LT AC Distribution Board 500 A 39 33/0.4 kV Station T/F 200 KVA 40 100 KVA DG Set along with associated accessories 41 EOT-Crane as per clause 3.10.7 Section-1 and Clause 29.0 of GIS Specification and as per EOT crane specification.(10T) 42 1.1 kV Copper Control Cable Armoured (FRLS type) for 220 kV bays of sizes 7CX4mm2, 2CX4mm2, 4CX4mm2, 2CX6mm2, 16CX2.5mm2, 10CX2.5mm2, 7CX2.5mm2, 3CX2.5mm2 etc. including junction box (as per HVPNL Tech spec.). 43 1.1 kV Copper Control Cable Armoured (FRLS type) for 33kV side of sizes 7CX4mm2, 2CX4mm2, 4CX4mm2, 2CX6mm2, 16CX2.5mm2, 10CX2.5mm2, 7CX2.5mm2, 3CX2.5mm2 etc. including junction box (as per HVPNL Tech spec.). 44 650/1100 Volts 3.5 core 240 mm2 aluminum power cable from Aux. T/F to ACDB 45 650/1100 Volt 3.5 core 70 mm2 aluminum cable for oil filtration set. 46 650/1100 Volt 4 core 16 mm2 armoured copper power cable for MLDB etc and other cable required as per contract. 47 Grounding system of the substation. Earthing Mat Material. The earth mat will be designed / quoted for soil resistivity of 50m. In case soil resistivity is more than 50m then the earth mat will be designed for actual soil resistivity. The payment of extra material to be used for earth mat shall be made on pro rata basis. The approximate area of earth mat to be laid is given in the corresponding columns of the substations. However, item will remain a Lot item.(9300 sq meter (approx) . Note:- Earthing of sub-station and equipments should be in line with HVPNL Tech. spec. and IEEE-80 considering fault and shock duration of 1 sec. 48 Fire Fighting equipments as per section-6:22.5 Kg Capacity FE CO2 type, Trolley Mounted 49 25 Kg Capacity FE DCP type, Trolley Mounted 50 DCP 9 Kg Capacity, Wall mounted 51 FE CO2 6.5 Kg Capacity, Wall mounted 52 DCP 6 Kg Capacity, Wall mounted 53 Foam Type 9 Litre Capacity, Wall mounted 54 Water CO2 9 Litre, Wall mounted 55 Fire Buckets(12 No.s with stand in one set) 56 Supply and installation of 2 fittings of 240W LED lamps with all accessories for Complete lighting of outdoor Switch yard area including all accessories, cables etc. as per clause 16.0 of section 7 of the specifications. 57 Complete lighting of road and street by providing 90W LED lamps on tubular steel poles at a distance of 15meter along the roads and streets including all accessories, cables etc. as per clause 16.0 of section 7 of the specification 58 (A) Supply and installation of 35W LED tube fitting on tubular steel poles along Fencing/ boundary wall at a distance of 30 meter including all accessories, cables etc. as per clause 16.0 of section 7 of the specification. 59 (B)Supply and installation of post top lantern 40W LED Lamps with all complete accessories at the entrance gate of sub-station. 60 Supply and installation of 40W LED Lamps with all complete accessories on corners of control room building. 61 High wall type split AC unit of 2 Ton capacity for computer room (2 no.) and C&R Panel room (4 no.) (as per technical specification) 62 Complete substation automation system for 220/33 kV substations including hardware (along with transducers)& software for present Bays and software for future bay along with associated equipment for the bays as defined in the technical specification, section sub-station automation system) as per technical specification. The scope for present and future is as under:- 220kV System: Present Bays: Line bays=4 T/F bays =2 Bus coupler =1 Future Bays Line bays=2 T/F bays =1 Bus coupler =033kV System: Present Bays: Line bays=16 T/F I/C bays =4 Bus Sectionliser bay =2 Capacitor bay =2 & Station T/F bay=2 Future Bays Line bays=8 T/FI/Cbays =2 Bus Sectionliser bay =1 Capacitor bay =1 & Station T/F bay=0 63 Computer system (SFF) with:Intel Core i5 processor with 11th generation or higher, 1x16GB DDR-IV RAM 2933 MHz or higher expandable upto 64 GB, 1 TB SSD or higher, 19.5” or higher TFT LCD Display (Backlit LED), Preloaded OS: Windows 11 Professional64-bit OEM or higher, with UPS (600VA offline UPS system 1x7AHx12V, MS-Office 2021 standard perpetual licensees or higher, etc. 64 Mono chrome Multi-functional Printer, A-4, 25 PPM, Copy & Scan function, Networking & Wi-Fi both, atleast 1 input tray 65 BOM FOR SAMAST COMPLIANT IEM ( ON SEPARATE CUBICLE) FOR 33 KV I/Ci. 3P4W Interface Energy Meters (ABT type) 0.2s Class 1A with TTB & BCS (02 no. for each 33 KV Incomer) 66 Testing of IEM System from NABL accredited lab 67 Wired Indoor Meters Panel suitable for 8 meters 68 16 P Industrial Grade un-managed Network switch 69 Data concentrator unit (DCU)/ communication Gateway (IG) with dual SIM Modem along with enclosure and accessories 70 Cat-6 cable-unshielded 71 PVC conduit Pipe - 3/4 with accessories for Cat-6 cable lot Lot (In line with cat-6 cable) 72 Armored Fibre Optic Cable (2 pair) 73 HDPE conduit - 40/33 with accessories (In line with armored cable for CT/PT) 74 4Cx4 Sqmm armored and 3Cx2.5 Sqmm, armoured (FRLS) copper control cables (as per note given below)Note- 4Cx4 Sqmm armored and 3Cx2.5 Sqmm armoured (FRLS) copper control cables shall be used for integration of IEMs. The provision of providing the same is to be covered in respective entry of cables of the BoQ. 75 Bolted type 220 kV single suspension string assembly with Silicone Rubber Polymer Composite Insulators (E&M strength 90kN) per string with hardware accessories including ball & socket connection and suspension clamp set suitable for single Tarantula (string). 76 Bolted type 220 kV single suspension string assembly with Silicone Rubber Polymer Composite Insulators (E&M strength 90KN) per string with hardware accessories including ball & socket connection and suspension clamp set suitable for Twin Tarantula (string). 77 Bolted type 33 kV single tension string assembly with Silicone Rubber Polymer Composite Insulators (E&M strength 90KN) per string with hardware accessories including ball & socket connection and tension clamp set suitable for twin Tarantula (string). 78 Bolted type 33 kV single suspension string assembly with Silicone Rubber Polymer Composite Insulators (E&M strength 90KN) per string with hardware accessories including ball & socket connection and suspension clamp set suitable for twin Tarantula (string). 79 C- Wedge connectors matching with conductor size. 80 Copper lugs glands, PVC ferrules for control cabling. 81 Fiber cleats, Aluminium clamps, bolts, nuts, washers etc for fixing control cables in trenches 82 Galvanized iron perforated tray with side coupler plate bolts, nuts, washers and clamps etc. of size 75x25x2 mm, 150X25X2mm, 100X25X2mm etc. & G.I. Conduits of 50mm/100mm dia from equipment to main trench as per Section-7, Switchyard erection. 83 AAC Tarantula Conductor(approx) 84 Spacers for Twin Tarantula conductor 85 7/3.15 Earthwire 86 U-bolt 20mm dia 87 Item for associated structure work‘Lattice type steel structure for 220kV GIS S/Stn.Sector-75A, Gurgaon. Supply of material, preparation of fabrication drawing, galvanizing and delivery of lattice type steel structure for tower and beams for 220/33kV switchyard fabricated from steel conforming to IS:2062 including nuts-bolts gusset plates foundation bolts and other accessories as per drawings supplied by the owner.Main S/Stn. Tower and beamTower type AT-1 88 Tower type AB-1 89 Tower type CT-4 90 Tower type CT-5 91 Beam type DD-1 92 Equipment Supporting Structure) 220 kV NCT drg. No. HTD/ST-150 93 220 kV CVT drg. No. HTD/ST-147 94 220 kV surge arrestor drg.No.HTD/ST-93R 95 33 kV NCT Drg. No. HTD/ST-88 96 33KV L&E switch HTD/ST-110 97 33 kV Surge Arrestor Drg. No. HTD/ST-89R 98 220kV Cable Support Structure for 220kV XLPE Cable(To be designed by the bidder) 99 33kV Cable Support Structure for 33kV XLPE Cable(Drg. No. HTD/ST-89R to be used for Cable Support Structure drawing) 100 220kV D/C line from Sohna Road to 220KV GIS sector-75A, Gurugram :PLC terminals (No.) 101 PLC terminal with Prot.coupler (No.) 102 Wave trap 1250A 103 LTU (P/P) (Set.) 104 48V Lead Acid Tubular San container Battery& SMPS Battery Charger (300AH) 105 HFcable (kms) 106 220kV D/C Panchgaon (PGCIL) to 220KV GIS sector-75A, Gurugram:PLC terminals (No.) 107 PLC terminal with Prot.coupler (No.) 108 Wave trap 1250A 109 LTU (P/P) (Set.) 110 HFcable (kms) 111 Equipments for maintenancePortable circuit breaker operation analyzer. 112 Digital Micro-Ohm meter for contact resistance measurement Ranges (0-100 ohm)(0-1 milliohm)(0-10 milliohm). 113 Dew Point meter 114 Portable partial discharge monitoring system for GIS. 115 Digital Earth resistance meter. 116 5 kV Automated insulation resistance tester. 117 Earth stick with lead suitable for use in 220/33kV Switchyard 118 SF-6 Gas filling and evacuating plant 119 SF-6 Gas leak detector (Portable) 120 Tools for gas handling 121 LT DC Leakage detector from control cabinets and LT cables 122 Mandatory Spares for 220KV GISGeneralComplete GIS modules, along with enclosure, all active parts such as conductor, conductor joints, shields, end covers etc. for each type of➢ Bus Bar Sections (including Bus Bar Interconnection Modules)➢ Bus Ducts Sections (including Compensators/expansion joints/bellows)➢ Bends➢ SF6/Air Bushing.➢ Oil/SF6 Bushing➢ Cable Termination kit 123 SF6 gas Pressure Relief Device assembly of each type 124 SF6 Pressure gauge cum switch /Density monitors and pressure switch as applicable, of each type 125 Coupling device for pressure gauge cum switch for connecting Gas handling plant of each type 126 Rubber Gaskets, “O” Rings and Seals for SF6 gas for GIS enclosures of each type 127 Molecular filter for SF6 gas with filter bags (10 % of total weight) 128 Control Valves for SF6 gas of each type 129 SF6 gas (20 % of total gas quantity) 130 Pipe length (Copper or Steel as applicable) for SF6 Circuit of each type (if applicable) 131 Locking device to keep the Dis-connectors (Isolators) and Earthing/Fast Earthing switches in close or open position in case of removal of the driving Mechanism 132 UHF PD Sensors of each type along with BNC Connector 133 Support Insulators (gas through) of each type (complete with metal ring etc.) 134 Gas Barriers of each type (complete with metal ring etc.) 135 SF6 to air bushing of each type complete in all respect 136 SF6 CIRCUIT BREAKERComplete Circuit Breaker (Three Phase) with interrupter, main circuit, enclosure and Marshalling Box with operating mechanism to enable one to one replacement of applicable type of CB by spare. (if applicable) 137 Fixed, moving and arcing contacts including insulating nozzles of each type (for Main Chamber & PIR Chamber as applicable) 138 Trip coil assembly with resistor as applicable 139 Closing coil assembly with resistor as applicable 140 Relays, Power contactors, push buttons, timers & MCBs etc. of each type 141 Auxiliary switch assembly of each type 142 Operation Counter 143 Wind scope / Observing window of each type 144 For Hydraulic Operated Mechanism, if applicableHydraulic operating mechanism with drive motor of each type 145 Ferrules, joints and couplings of each type 146 Hydraulic filter of each type 147 Hose pipe of each type 148 N2 Accumulator of each type 149 Valves of each type 150 Pipe length (copper & steel) of each size & type 151 Pressure switches of each type 152 Pressure gauge with coupling device of each type 153 Hydraulic oil (20% of total Oil quantity) 154 Pressure Relief Device of each type 155 For Spring Operated Mechanism, if applicableComplete Spring Operating Mechanism including charging mechanism etc. of each type 156 Spring Charging Motor 157 For Hydraulic-Spring Operated Mechanism, if applicableComplete Hydraulic-Spring Operating Mechanism including charging mechanism etc. of each type 158 Spring Charging Motor 159 Pressure switches of each type 160 Pressure gauge with coupling device of each type 161 Disconnector Switches/Earthing SwitchesComplete set of 3-phase dis-connector of each type including main circuit, enclosure, driving mechanism and support Insulator etc. to enable complete one to one replacement of all applicable type of Isolator by spare 162 Complete set of 3-phase Maintenance Earthing switch of each type, including main circuit, enclosure, driving mechanism and support Insulator etc. to enable complete one to one replacement of all applicable type of Earth Switch by spare 163 Complete set of 3-phase Fast Earthing switch of each type, including main circuit, enclosure, driving mechanism and support Insulator etc. to enable complete one to one replacement of all applicable type of Earth Switch by spare (if applicable) 164 Copper contact fingers & corona shield for dis-connector male & female contact–for one complete (3-phase) dis-connector of each type 165 Copper contact fingers & corona shield for Maintenance Earthing switch male & female contacts, for one complete (3- phase) earthing switch of each type 166 Copper contact fingers & corona shield for Fast Earthing switch male & female contacts, for one complete (3-phase) earthing switch of each type (if applicable) 167 Open/Close contactor assembly, timers, key interlock, interlocking coils, relays, push buttons, indicating lamps, Power contactors, resistors, fuses, MCBs & drive controlcards etc. one of each type for one complete MOM boxFor Disconnector 168 For Maintenance Earth switch 169 For Fast Earthing Switch (if applicable) 170 Limit switches and Aux. Switches for one complete MOM BoxFor Disconnector 171 For Maintenance earth switch 172 For Fast Earthing Switch (if applicable) 173 Drive Mechanism of each typei. For Disconnector 174 ii. For Maintenance earth switch 175 iii. For Fast Earthing Switch (if applicable) 176 Motor for Drive Mechanism of each typei. For Disconnector 177 ii. For Maintenance earth switch 178 iii. For Fast Earthing Switch (if applicable) 179 CURRENT TRANSFORMERComplete CT of each type and rating as supplied with enclosure and primary conductors to enable one to one replacement of all applicable type/rating of CT by spare 180 Voltage TransformerComplete PT of each type with enclosure to enable one to one replacement of all applicable type/rating of VT by spare (if applicable) 181 SURGE ARRESTORComplete Gas insulated Surge arrester of each type and ratings with enclosure and insulator (if applicable) 182 Surge counter/ monitor of each type (if applicable) 183 Local Control Cubicle (LCC)Aux. relays, Contactors, Push Buttons, Switches, Lamps, Annunciation Windows, MCB, Fuses, Timers, Terminal Blocks etc. of each type & rating 184 MANDATORY SPARES (33kV GIS)Line voltage transformer (3 nos.) 185 Bus voltage transformer (3 nos.) 186 Current transformers suitable for incomer panel (3 nos.) 187 Current transformers suitable for transformer panel (3 nos.) 188 Current transformers suitable for bus coupler panel (3 nos.) 189 Trip Coil 190 Closing Coil 191 CB Spring charging motor 192 Auxiliary switch (2 no. each type) 193 Disconnector motor for isolator 194 Disconnector motor for earth switch 195 Gas density switch 196 Bursting disc / pressure relief plate complete 197 Capacitive voltage indicator (6 nos.) 198 Civil portionEARTH WORK IN FILLING: Earth filling with good earth (as per satisfaction of Executive Engineer/Civil Works Division), laying in layers (as per specification), dressing, including carriage, irrespective of lead, loading, unloading, watering and compaction in layers with roller including compensation of earth complete in all respect. 199 FOUNDATIONS :Design engineering, supply of labour,T&P,material and construction of RCC footings & pedestals etc. for steel gantry and equipment structures complete in all respects as per technical specifications including cost of excavation,concreting,cement,reinforcement steel,form work,grouting,holding down bolts,back filling etc. and other items not mentioned herein but required for the completion of work.GANTRY TOWERS AT-1 200 CT-4 201 CT-5 202 EQUIPMENT 220kV side220kV LA 203 220kV CVT 204 220kV NCT 205 33 kV side33kV LA 206 33kV NCT 207 CABLE SUPPORT STRUCTURE Design, Engineering, Supply of labour, material and Construction of cable support structure foundations including all associated works, RCC, PCC, reinforcement steel, misc. structural steel and other items not mentioned herein but required for the completion of work as per technical specifications. 220 KV Cable Support Structure 208 33kV Cable Support Structure 209 ROADSSupply of labour, material and construction of cement concrete roads and walkways/shoulders from NH/SH/etc. to Switch yard/Switch house building as per GELO/CLO as per sectional detail drawing no. HCD/SK-181 R1 and technical specification.6.0m wide road (Near main gate of substation) 210 5.0m wide road within substation 211 3.66m wide road within substation 212 CAPACITOR BANK FOUNDATIONSDesign, Engg. & supply of labour, material & construction of foundations for capacitor bank with capacitor unit (with allied equipments) & series Reactor etc. including chain link fencing 1.8M height around cap. bank complete in all respect including any other items not specifically mentioned herein but required for completion of job as per technical specification.1x21.744MVAR 33kV capacitor bank 213 ROAD CULVERTDesign, Engineering and const. of Pipe culvert(s) at suitable locations under the approach road (from main PWD/ HUDA/Municipal/Village road to the sub-station entry point) including, cost of labour, material complete in all respects as per I.R.C. Standards. 214 TRANSFORMER FOUNDATIONDesign engineering, supply of labour, material and construction of foundations including T/F radiator foundations etc. complete in all respect including all associated works, RCC, PCC, Reinforcement steel, misc. structural steel and other items not mentioned here in but required for the completion of work as per technical specifications. In case additional foundation is/ are required as per approved equipment drawing, the same shall be constructed by the successful bidder without any extra cost toHVPNL.Such drawing(s)shall, however, be got approved from HVPNL.100MVA,220/33kV T/F foundationincluding associated foundations for radiator, NIFPES, fire fighting system etc. complete in all respect. 215 200KVA 33/0.4kv Station T/F 216 100kVA DG Set 217 OUTDOOR CABLE TRENCHESSupply of labour, material such as cement, reinforcement steel, GI angles, flats, PCC & brick pillars below cable trenches for construction of Out-Door Cable Trenches (ODCT) of required depth/ type with pre-cast RCC covers including associated works like Cable Trench Culverts crossings for roads and sumpit-cum-pump chamber with 2HP motor of reputed make, starter, volt meter, amp-meter etc. as per approved Trench layout plan, HVPNL drgs. & tech. specs. complete in all respect.D-type Trench 218 E-type Trench 219 F-type Trench 220 G-type Trench 221 H-type Trench 222 Road Culvert 223 Sump pit cum pump chamber 224 SITE SURFACINGProviding, supplying & laying 100mm thick in two layers of 50mm each of 20mm nominal size uncrushed/crushed/ broken stone pebbles gravel fill including dressing, rolling & compacting complete in all respects as per specs. & instructions of engineer incharge. 225 Providing, supplying & laying 100mm thick PCC (1:4:8) using 20mm nominal coarse aggregates and supplying & spreading 100mm thick layer of 40mm nominal size uncrushed/ crushed/broken stone pebbles over the PCC including construction of toe wall (exposed wall plastered with cement mortar 1:5) to hold 40mm single size uncrushed/ crushed /broken stone pebbles wherever required in the bays covered under the present scope as detailed in the GELO & instructions of engineer incharge. 226 RCC retaining wallSupply of labour, material and construction ofRCC retaining wall below DPC to retain the earth filling complete in all respect. Further, if L-shape retaining wall is required to be constructed as per site, the successful bidder shall develop the designs & drawings as per the soil investigation report attached in specification and shall get these checked/vetted from any professsional institute as per contract before final approval. Nothing extra shall be paid on this account. i. Difference between NGL & FGL from 2.5 to 3.5 mtr. 227 ii. Difference between NGL & FGL from 3.5 to 4.0 mtr. 228 Design engineering, supply of labour,material and construction of RCC T/L shaped retaining wall below DPC to retain the earthfilling complete in all respect and design /drawing shall be got checked/ vetted from any professsional institute as per contract before final approvalNothing extra shall be paid on this account. Iii. Difference between NGL & FGL above 4.0 mtr. 229 BOUNDARY WALL;Supply of labour, T&P, material & construction of front, side & U/C boundarybelow DPC level as per GELO/CLO, tech. spec. & HVPNL drgs including excavation, PCC, brickwork, back filling, plaster, painting etc. complete in all respects. 230 Supply of labour, material and construction of front, C & U/C boundary walls above DPC including main gate foundationsas per GELO/CLO, technical specifications. & HVPNL drg. HCD/TS-1176 R3 including DPC complete in all respect..6 ft. high U/C B/wall with barbed wire on angles at top. 231 4½ ft. high front wall including providing grill at top of wall & construction of gate pillars. 232 4½ ft. high side wall with barbed wire on angles at top of wall. 233 MULTISTOREY 33kV GIS CUM CONTROL ROOM BUILDINGDesign including architectural and structural design/drawings, Engineering, supply of labour,T&P and material etc.for construction of multi storey GIS Hall comparising of ground and1st floor (to accumulate 33kV GIS & Control Room Building) including exterior weather proof paint, interior emulsion, all internal services like water supply and providing of 5000ltr. Capacity double layer Sintex/ Diplast PVCtank,Sewerage System, electrification including wiring, receptacle, modular switches, lighting, maximum 20W 4ft. long LED tube swith fittings minimum 1960 lumens, bulk headlig hts including fixtures. ceiling/ exhaust fans, plinth protection, closed drain (RCC Pipe)around building, Indoor trenches and provision for mechanical operated crane system adjacent to building, Soakage pit ,connection of sewerage system to Soakage pit/ sewerage system of local authority (as applicable), connection to main water supply system of local authority, bore (asapplicable)etc. and any other item not mentioned here in but required for completion of job as per specifications. Minimum size of the buildings has been provided in the GELO.Since the detailed engineering is in the scope of the successful bidder, no claim for increase in size of the building shall be admitted.The GIS Hall should be equipped with fire detection system and shall be done by the succesfull bidder without any extra cost to employer.The building should be design to ensure early warning and prompt response in case offire.The system must include advance smoke detection system, advance heat detection system, audible and visual alarms alongwith alarm panels, fire extinguishers, fire buckets, warning signs, exitplans, etc complete in all order torun the system efficiently, wherever required as per latest IS Codal provision and in consultation with engineer incharge. 234 U/C FENCING & GATES Providing & fixing chain link fencing including foundations, GI angle iron posts and gate(s) complete as per electrical layout & tech. spec. & as per drawing attached. 235 PCC PAVEMENTConstruction of PCC pavement in front, rear or side (as per site requirement of the switch house building) as per drawing no. HCD/SK-172 & technical specifications. 236 GIS Hall / BuildingDesign,Engineering including architectural & structural, supply of labour, material and construction of GIS building with ventilation system including crane hoisting system (EOT), equipment foundations as detailed in the bill of quantities under Annexure-1 of Section of bid/ contract documents , electrification including wiring, receptacle, modular switches, maximum 20W 4ft. long LED tubes with fittings minimum 1960 lumens, bulk head LED lights including fixtures, ceiling/ exhaust fans, stair case etc.interior & exterior acrylic emulsion, paint, RCC paving /plinth protection starting from the building upto1.5 m clear distance for the full length width of the building, closed drain around the building (i.e RCC Pipe)etc. complete in al lrespect for GI Shall / building and any other item not mentioned here in but required for completion of job as per specifications. The building should be equipped with fire detection system and shall be done by the succesfull bidder without any extra cost to employer.The building should be design to ensure early warning and prompt response in case offire. The system must include advance smoke detection system, advance heat detection system, audible and visual alarms alongwith alarm panels, fire extinguishers, fire buckets, warning signs, exit plans, etc complete in all order to run the system efficiently , wherever required as per latest IS Codal provision and in consultation with engineer incharge.220kV GIS Hall 237 DRAINAGE-CUM-RAIN HARVESTING SYSTEMSupply of labour, material for construction ofrecharge structures with bore well(s) as per HVPN drawings & specs. complete in all respect. The location of recharge structures shall preferably be located on corner(s) of the substation and shall be got decided from the concerned Engineer in-Charge on the basis of surroundings of the substation(s). In case ground water table is less than 8m from FGL, rain harvesting well shall not be constructed (the drainage system with sump pit is to be constructed as per item mentioned below). 238 The successful bidder shall evolve design & drawing for drains, manholes with RCC covers andsettlement tankincluding preparation of drainage layout drawing for disposal of rain water from building’s roof top & switch yard (s/stn.) area into respective bore well(s) in such a way that there shall be no ponding of water on the roof and switch yard (s/stn.). The layout so developed shall be got approved from the employer. The location of sump-pit-cum-pump chamber shall preferably be locatedon corner(s) of the s/stn. and shall be got decided from the concerned Engineer in-Charge on the basis of surroundings of the substation(s). The successful bidder will also supply labour and material for construction of sump-pit-cum-pump chamber as per HVPNL drgs. & provide one no. non clog pump(s) of 5HP of reputed make capacity with main switch, starter, volt meter, Amp. Mtr. etc. (for each sump pit) for disposal of excess water to outfall point. Any other item(s) not mentioned herein but is/are required for completion of works shall be done by the successful bidder without any extra cost to the employer.Drain Section-1 239 Drain Section-2 240 Drain Section-3 241 Road Crossing 242 Trench Crossing 243 Sump Pit Cum Pump Chamber 244 REMOVAL OF MALBARemoval/Disposal of malba irrespective of lead including loading & unloading etc. complete in all respect. Malba shall be disposed of to a suitable undisputed place outside the substation. as per Govt. norms. The successful bidder shall be responsible in case some dispute arise on account of disposal of malba/sludge at a disputed site. 245 CONSTRUCTION OF ANTI FIRE WALLConstruction of RCC anti fire wall of suitable height between T/F as per HVPNL drawing and all associated works including supply of labour, material, cement, reinforcement steel, steel form work etc. as per technical specification. 246 RCCM-20 inclusive of labour, material, shuttering, steel reinforcement etc. complete in all respects to compensate excess quantity required to be executed due to difference in existing ground level and the formation level to be fixed after contouring or difference on account of revised drawing issued at the time of construction and the tender drawing.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 4
20.
Power #9158096 Technical Bid
Rate Contract For Upkeep / Maintenance Of 66-33 / 11 Kv Receiving Stations Along With Their 66 / 33 Kv Lines And Fabrication & Handling Of Material Of Divisional Store Under The Jurisdiction Of Sub Transmission Division, Jpdcl, Kathua For The Year 2022-23 Or Till The Next Contract.- 1 Erection Of 16 Mtr Long Steel Tubular Pole With Planting Depth Of 1 / 6 Th Of The Height Of The Pole Including Digging Of Pits, Disposal Of Extra Earth, Collection Of Boulders And Filling Back. 2 Erection Of 13 Mtr Long Steel Tubular Pole With Planting Depth Of 1 / 6 Th Of The Height Of The Pole Including Digging Of Pits, Disposal Of Extra Earth, Collection Of Boulders And Filling Back. 3 Erection Of 11 Mtr Long Steel Tubular Pole With Planting Depth Of 1 / 6 Th Of The Height Of The Pole Including Digging Of Pits, Disposal Of Extra Earth, Collection Of Boulders And Filling Back. 4 Erection Of 11 Mtr Long Pcc Pole With Planting Depth Of 1 / 6 Th Of The Height Of The Pole Including Digging Of Pits, Disposal Of Extra Earth, Collection Of Boulders And Filling Back. 5 Erection Of 9 Mtr Long Steel Tubular Pole With Planting Depth Of 1 / 6 Th Of The Height Of The Pole Including Digging Of Pits, Disposal Of Extra Earth, Collection Of Boulders And Filling Back. 6 Erection Of 9 Mtr Long Pcc Pole With Planting Depth Of 1 / 6 Th Of The Height Of The Pole Including Digging Of Pits, Disposal Of Extra Earth, Collection Of Boulders And Filling Back. 7 Painting Of 16 Mtr Long Steel Tubular Poleincluding Fixtures With One Coat Of Red-Oxide And Two Coats Of Silver ( Aluminium ) Paint 8 Painting Of 13 Mtr Long Steel Tubular Poleincluding Fixtures With One Coat Of Red-Oxide And Two Coats Of Silver ( Aluminium ) Paint 9 Painting Of 11 Mtr Long Steel Tubular Poleincluding Fixtures With One Coat Of Red-Oxide And Two Coats Of Silver ( Aluminium ) Paint 10 Painting Of 09 Mtr Long Steel Tubular Poleincluding Fixtures With One Coat Of Red-Oxide And Two Coats Of Silver ( Aluminium ) Paint 11 Cement Bottoming In 1:2:4 Mix Including Excavation And Form Work As Per Rec Standards. ( 16 / 13 / 11 / 9 Mtr Long Poles ( Complete Job ) 12 Fixing Of Galvanisedspiral Earthing Of Swg No. 8, G.I Wire Of 115 Turns Confirming To Rec-J1 Construction Standard, ( J1 ) 13 Fixing Of 66 / 33Kv Galvanised Guy Set ( Guy Wire, Guy Rods, Turn Buckle Plate , Guy Insulators ) Confirming To Is 2141 / 1979 Or The Latest Version Thereof Including Digging Of Pits & Refilling 14 Collection Of Snapped Acsr Cond. And Re-Stringing, Tensioning , Binding Of Acsr Conductor, ( 100Mm2 Acsr Conductor ) 15 Collection Of Snapped Acsr Cond. And Re-Stringing, Tensioning , Binding Of Acsr Conductor, ( 150Mm2 Acsr Conductor ) 16 Collection Of Snapped Acsr Cond. And Re-Stringing, Tensioning , Binding Of Acsr Conductor, ( 200Mm2 Acsr Conductor ) 17 Dismantling Of Steel Tubular Pole Including Carriage Up To Dumping Site, ( 16 Mtr. Long ) Up To Distance Of 50 Mtr 18 Dismantling Of Steel Tubular Pole Including Carriage Up To Dumping Site, ( 13 Mtr. Long ) Up To Distance Of 50 Mtr 19 Dismantling Of Steel Tubular Pole Including Carriage Up To Dumping Site, ( 11 Mtr. Long ) Up To Distance Of 50 Mtr 20 Dismantling Of Pcc Pole Including Carriage Up To Dumping Site, ( 11 Mtr. Long ) Up To Distance Of 50 Mtr 21 Dismantling Of Steel Tubular Pole Including Carriage Up To Dumping Site, ( 9 Mtr. Long ) Up To Distance Of 50 Mtr 22 Dismantling Of Pcc Pole Including Carriage Up To Dumping Site, ( 9 Mtr. Long ) Up To Distance Of 50 Mtr 23 Dismantling Of Three / Four Pole Structure, Opening Of Channels, Crossarms, Angles ( Complete Job. ) 24 Dismantling Of Two Pole Structure, Opening Of Channels, Crossarms, Angles ( Complete Job. ) 25 Straightening Of Tilted Steel Tubular Pole ( 16 Mtr. Long ) 26 Straightening Of Tilted Steel Tubular Pole ( 13 Mtr. Long ) 27 Straighteningof Tilted Steel Tubular Pole ( 11 Mtr. Long ) 28 Straighteningof Tilted Pcc Pole ( 11 Mtr. Long ) 29 Straighteningof Tilted Steel Tubular Pole ( 9 Mtr. Long ) 30 Straighteningof Tilted Pcc Pole ( 9 Mtr. Long ) 31 Unloading Of Steel Tubular Pole Including Carriage Up To Dumping Site, ( 16 Mtr. Long ) Up To Distance Of 50 Mtr 32 Unloading Of Steel Tubular Pole Including Carriage Up To Dumping Site, ( 13 Mtr. Long ) Up To Distance Of 50 Mtr 33 Unloading Of Steel Tubular Pole Including Carriage Up To Dumping Site, ( 11 Mtr. Long ) 34 Unloading Of Steel Tubular Pole Including Carriage Up To Dumping Site, ( 9 Mtr. Long ) Up To Distance Of 50 Mtr 35 Loading Of Steel Tubular Poles Including Carriage Up To Dumping Site, ( 16 Mtr. Long ) 36 Loading Of Steel Tubular Poles Including Carriage Up To Dumping Site, ( 13 Mtr. Long ) 37 Loading Of Steel Tubular Poles Including Carriage Up To Dumping Site, ( 11 Mtr. Long ) 38 Loading Of Steel Tubular Poles Including Carriage Up To Dumping Site, ( 9 Mtr. Long ) 39 Extra Carriage From Dumping Site, ( 16 Mtr. Long ) Up To Site Of Work 1St 100 Mtr 40 Extra Carriage From Dumping Site, ( 13 Mtr. Long ) Up To Site Of Work Ist 100 Mtr 41 Extra Carriage From Dumping Site, ( 11 Mtr. Long ) Up To Site Of Work Ist 100 Mtr 42 Extra Carriage From Dumping Site, ( 9 Mtr. Long ) Up To Site Of Work Ist 100 Mtr 43 Unloading Of Steel Of Sorts , ( Steel ) 44 Loading Of Steel Of Sorts , ( Steel ) 45 Unloadingof Conductor Reels, ( 100Mm² / 150Mm² / 200Mm² Acsr Conductor ) 46 Loadingof Conductor Reels, ( 100Mm² / 150Mm² / 200Mm² Acsr Conductor ) 47 Fixing Of 66-33 Kvdiscinsulator ( 70 Kn ) 2008 Standards, ( Porcelain ) 48 Fixing Of 66-33 Kv Disc Fitting ( 70 Kn ) 2008 Standards, ( Polymer ) 49 Fixing Of 66-33 Kv Insulators ( 10 Kn ) Standards, ( Porcelain ) 50 Fixing Of 66-33 Kv Pin Insulators ( 10 Kn ) Suitable For 100 / 150 / 200Mm² Acsr Conductor. 51 Replacement / Fixing Of 66-33 Kvtension Fittings ( Socket & Ball Type Or T&C Type ) For Acsr 52 Replacement / Fixing Of 66-33 Kv Tension Fittings ( Socket & Ball Type Or T&C Type ) For Acsr 150M² 53 Replacement / Fixing Of 66-33 Kv Tension Fittings ( Socket & Ball Type Or T&C Type ) For Acsr 200M² 54 Straighteningof X-Arms Of Different Sizes ( 100X50x50x6 Mm Channel Iron, 50X50x6mm Angle Iron ) Duly Painted With One Coat Of Red-Oxide And Two Coats Of Silver Paint Fixing With Different Sizes And Sorts Of Nuts, Bolts And Washers, ( Channel Iron X-Arms, Angle Iron-X-Arms, Pole Tops ) 55 Straighteningof Angle Ironof Different Sizes ( 65X65x6 Mm Channel Iron, 50X50x6mm Angle Iron 56 Repair And Re-Erection Of Cradle For Guard Netting With Gi Wire 8No Including Wire Binding, Cutting / Bending Of Gi Wireas Per Rec Standards 57 Branch Cutting, 66- 33 Kv Lines 58 Removing Of Wild Climbers / Vegetation Around 66 / 33 Kv Poles 59 Removing Of Wild Climbers / Vegetation Around 66 / 33 Kv Tower 60 Removing Of Wild Climbers From Top Of 66-33 Kv Lines. 61 Removing Of Wild Climbers From Peak, Cage, Cross Arm Of 66-33 Kv Old Tower Line 62 Patrolling Of 66 / 33 Kv Line ( Routine / Under Fault ) 63 Tightening Of Loose Guys 64 Dismantling & Re-Erection Of Damaged Guys Including Digging Of Pit & Refilling The Same 65 Replacement Of Damaged Disc Insulator In Tension String 66 Replacement Of Cross Arms Of Sizes 100X50x6 67 Replacement Of Angle Iron Of Sizes ( 65X65x6, 50X50x6 ) 68 Replacement Of Pin Insulator On Four / Three / Double Pole Structure 69 Replacement Of Pin Insulator On Single Pole Structure 70 Replacement Of Worn-Out / Damaged Jumper Of 66-33 Kv Towerlines 71 Replacement Of Disc Insulator, Suspension Fitting Of 66-33 Kv Towerlines 72 Replacement Of Worn-Out / Loose / Damaged Jumper Of 66-33 Kv Lines ( Sets Of3 Nos ) 73 Local Earthing Of 66 / 33 Kv Lines By Way Of Using Discharge / Earth Rods At Faulty Site To Avoid Accident Due To Any Induction While Working On Line. 74 Tightening / Restringing Of Loose Acsr Dog 100 Mm2 75 Tightening / Restringing Of Loose Acsr Wolf 150 Mm2 76 Tightening / Restringing Of Loose Acsr Panther200 Mm2 77 Dismantling & Re-Erection Of Acsr Dog 100Mm2 Including Collection Of Dismantled Conductor , Making Of Small Bundles And Its Carriage 78 Dismantling & Re-Erection Of Acsr Wolf 150Mm2 Including Collection Of Dismantled Conductor , Making Of Small Bundles And Its Carriage 79 Dismantling & Re-Erection Of Acsr Panther 200Mm2 Including Collection Of Dismantled Conductor , Making Of Small Bundles And Its Carriage 80 Dismantling Of Stay Sets Complete 81 Upkeep / Maintenance Of 66-33 / 11 Kv Receiving Sub Stations A ) Routine Maintenance Of 66 Kv Outdoor Sf6 By Way Of Tightening Of Loose Nuts And Bolts, Greasing / Lubrication Of Movable Parts, Checking The Movable Alignment Of Different Phases, Cleaning Of Insulating Chambers, Etc 82 33 Kv Vcb Repairs & Renovationby Way Of B ) Setting Of Mechanical Assembly / Replacement Of Damaged Spring / Repair Of Locking & Charging System 83 C ) Replacement Of Tripping Coil / Closing Coil 84 D ) Replacement Of Damaged Vacuum Interrupter 85 E ) Replacement Ofbushing Including Clamps 86 66 Kv C&R Panel: Replacement Of Different EquipmentSa ) Ammeter, Volt Meter Indication , Lamps, Fuses, Trip Close Switch , Selector Switchidentification Of Panel Wiring Faults & Its Rectification 87 33 Kv C&R Panel: Replacement Of Different EquipmentSa ) Ammeter, Volt Meter Indication , Lamps, Fuses, Trip Close Switch , Selector Switchidentification Of Panel Wiring Faults & Its Rectification 88 B ) Replacement Of Different Relays - Mitnumerical Relay / Electro-Mechanical Relay / Master Trip Relay / Differential Relay / Auxiliary Relay Etc. 89 Installation, Testing, Commissioning Of 66-33 Kv Control Relay Panels ( Complete Job ) 90 Complete Testing Of Relays Setting Of Testing Kit, Interconnection Between Various Points Of Panel With Respect Tosecondary Injection Key On Various Current Taps, Recording The Observation Thereof. All Modifications Necessary To Achieve Desired Results. 91 Control Cable Replacement Of Damagedcontrol Cables Of All Typesincluding Binding With Pvc Belts / Binding Wire, Peeling Of Insulation And Fixing Of Proper Size Thimble Connecting The Cable After Identification Of Each Core To Both Ends I.E. Panel To Cts / Panel Topts / Panel To Breaker And Making Functional Of 33 Kv Outdoor Breakers, Protection , Alarms, Annunciation ( Complete Job ) 92 Upkeep Of Earthing Of Aux. Transformer 93 Upkeep Of Earthing Of Power Transformer 94 Upkeep Of Earthing Of 66 / 33 / 11 Kv La 95 Providing Of Extra Earthing For Improvement Purpose ( Complete Job ) 96 Upkeep Of Earth Mat Of Out Door Yard 97 Replacement Of Damaged Earth Mesh In Sub-Station As Per Approved Map & Design. 98 Excavation Of Trenches Of 0.6 Mtr Depth And 2.0 Mtr Wide Mtr In Normal Soil / Hard Soil 99 Repairing / Laying Of Ms Flat And Ms Rod In Deep Excavated Trench And Welding Of Ms Flat & Ms Rod With Mesh. 100 Repairing Of Earthing With Spikes Of Ms Rod 20Mm, 3 Mtr In Length As Per Rec Drawing 101 66-33 / 11 Kv Power Transformera ) Opening Of Transformer Tank Top Cover To Prevent Oil Leakage From Top ( If Required To Facilitate Maintenance Of Transformer After Removing The Required Accessories ) , , Draining / Re-Filling Of Required Oil, Change Of Gaskets Of Valves / Radiators / BuchholzS Relay Radiators Valves Of Power Transformer Of Capacity: 3.15 Mva To 20 Mva 102 B ) Replacement Of Silica Gel 103 C ) General Inspection By Through Inspection Of Each Individual Parts, Ratio Test By Applying Voltage On Hv Side And Measuring Lv Voltage On Various Tap Positions, Checking Of Buchholz Relay, Surge Relay Conservator, Sensors, Measurement Of 1R-Value Dialectic Strength Of Oil, Cleaning Of Power Transformer Etc 104 D ) Replacement Of Any One Of The Following I.E. Temperature Indicators, Gas Operated BuchholzS Relay, Oil Temperature Indicator, Winding Temperature Indicator Etc 105 E ) Preventing Of Leakage By Changing Main Gaskets After Removing The Old Gasket, Replacement Of Hv / Lv Busing & Bush Rod, Ring And Rubber Washers ( Complete Job To Prevent Leakages ) 106 F ) Cleaning Of Scale Deposited Over The Body And Radiators Of The Power Transformer With Thinner / Detergent And De-Rusting In Perfect Manner. ( Routine Work ) 107 G ) Cleaning Of Lv / Hv Bushings Of Power Transformer ( Routine Work ) 108 H ) Replacement Of Bus Bars Ofpower Transformer 109 I ) Replacement Of Lv / Hv Clamps Of Power Transformer 110 Oil Topping Of Power Transformer 10 Mva To 20 Mva 111 Oil Topping Of Power Transformer 4 Mva To 6.3 Mva 112 Oil Topping Of Power Transformer 3.15 Mva 113 Recording Of Ir Values Of Transformers 114 Installation, Testing And Commissing Of Power Transformer 66-33 / 11 Kv Installation Of Lv / Hv Bus Bars With Proper Care, Of Transformer For Any Leakagecommissioning Of Power Of Transformers By Applying Low Voltageapproximately Equal To Impedance Voltage On Hv Side And Short Circuiting The Lv Terminals, Energizing The Transformer By Applying Required Primary Voltage To It & Keeping The Transformer On No Load To Observe The Behaviour Of Transformer, Setting On 25% Of The Load On The Transformer For A Period Of At Test 6 Hours And Observation Of Oil Including Temperature, Increase The Transformer Is Fully Loaded And Topping Of Oil.A ) 20 Mva 115 B ) 10 Mva 116 C ) 6.3 Mva 117 D ) Upto 5 Mva 118 Checking And Tightening Of Jumpers, Droppers In 66 / 33 Kv Outdoor Yard 119 Replacement Of T / Pg Clamps 120 Replacement Of Disc Insulators Including Its Hardware. 121 66 / 33 Kv La & 11 Kv Stn. Type Lareplacement Of 66 Kv, 33 Kv & 11 Kv Lightening Arrestor Including Jumpering And Earth Connecting In All Respect. A ) 66 Kv La 122 B ) 33 Kv La 123 B ) 11 Kv La 124 Separate Pipe Earthing / G.I Rod Earthingas Per Rec Drawing 125 Replacement Of Pipe Earthing / Rod Earthing With New One 126 Installation, Testing And Commissioning, Replacement Of 66 Kv Isolators 127 Installation, Testing And Commissioning, Replacement Of 33 Kv Isolators 128 Replacement Of11 Kv Isolators 129 Repair & Renovationof 66 / 33 Kv And 11 Kv Isolators Including Setting Right Its Alignment For Proper Operation, Lubrication / Greasing Of Jaws, Bearings OperatingS Handle Etc ( Complete Job ) 130 Replacement Of Worn-Out / Heated Pad Clamp / Isolator Clamps Of 66 / 33 / 11 Kv Isolator By Way Of Dismantling. Drilling Of Holes On New And Fixing ( Complete Job ) 131 Repair & Renovationof Isolator Jaws 66 / 33 Kv And 11 Kv Isolators. ( Complete Job ) 132 Replacement Of Post Insulator / Tendon Pipes / Operating Box By Way Of Dimentalling, Necessary Fabrication Where Ever Required For Proper Operation Of 66 / 33 / 11 Kv Isolators. 133 66-33 Kv Ctsinstallation, Testing And Commissioning Of 66-33 Kv Cts ( Of All Ratios ) Complete Job 134 66-33 Kv Ctsrepairs & Renovation Of 66 / 33 Kv Cts By Way Of Replacing Shorting Strips, Connecting Rod, Transformer Oil, Damaged Insulator ( CtS Of All Ratios ) 135 Replacement Of 66 Kv Outdoor Type Ct Of Different Ratio And Dismantling Of Damaged Ct ( CtS Of All Ratios ) 136 Replacement Of 33 Kv Outdoor Type Ct Of Different Ratio And Dismantling Of Damaged Ct ( CtS Of All Ratios ) 137 Oil Topping Of 66 / 33 Kv Ct & Pt By Way Of Opening Of Top Cover And Refixing With New Gaskets If Necessary And Preventing Of Oil Leakages If Any. ( Complete Job ) 138 66-33 Kv Ptsinstallation, Testing And Commissioning Of 66-33 Kv Pts ( Complete Job ) 139 66 Kv Ptsreplacement Of 66 Kv Outdoor Type Pt And Dismantling Of Damaged Pt, Dragging To Installation / Loading Site, Lifting From Ground To Steel Structure. 140 33 Kv Ptsreplacement Of 66 Kv Outdoor Type Pt And Dismantling Of Damaged Pt, Dragging To Installation / Loading Site, Lifting From Ground To Steel Structure 141 66 Kv Post Insulatorreplacement Of 66 Kv Post Insulatorand Dismantling Of Damaged Pi, Dragging To Installation / Loading Site, Lifting From Ground To Steel Structure. 142 33 Kv Post Insulatorreplacement Of 33 Kv Post Insulatorand Dismantling Of Damaged Pi, Dragging To Installation / Loading Site, Lifting From Ground To Steel Structure. 143 Cleaning Of Porcelain Bushing, Tightening Ofpt / Ct Clamps, Derusting & Painting Of Body Of 66 / 33 Kv Pts & Cts 144 Tightening Of Nuts & Bolts, Replacement Of Oval Thread Bolts, Chipping By Way Of Welding To The Bolts After Tightening In A Single Bay 145 Painting With Mix Red Oxide Paint Two Coats Of Approved Make On Steel Works After Cleaning With Wire Brush / Sand Paper 146 Painting Of Steel Structure Erected In Outdoor Yard With Aluminium Paint Two Coats With Approved Brand Andfixture To Given An Even Surface 147 Battery Banka ) Repair & Maintenance Of Battery Set Including Maintaining Specific Gravity, Electrolyte Level, Cleaning, Checking, Tightening Of Battery Terminals In All Respects It Includes Measuring Voltage Of Each Battery. 148 B ) Tightening Of All Nut And Bolts, Replacement Of Damaged Battery Cells 149 C ) Installation, Testing And Commissioning Of Battery Bank ( Complete Job ) 150 Battery Chargerrepair / Renovation Battery Charger For Proper Functioning By Way Of Replacement Of Rectifier Unit, Ammeter, Voltmeter, Mcb, Cooling Fan, Led Indications, Buzzer Alarms For Ov / Uv Etc ( Complete Job ) 151 Repair And Maintenance Of Dc Board, Identification Of Fault In Respect Of Cableand Its Replacement, Replacement Of Damaged Mccb, Kit Kat, Bus Bar & Other Allied Job. 152 Repair And Maintenance Of Ac Board, Identification Of Fault In Respect Of Cableand Its Replacement, Replacement Of Damaged Mccb, Kit Kat, Bus Bar & Other Allied Job. 153 Installation, Testing And Commissioning Of Battery Charger ( Complete Job ) 154 Deweeding Of Vegetation In Outdoor Yardremoving Of Stone Metal, Deweeding Of Unwanted Vegetation, Spreading Of Stone Metal Collected Earlier For Removal Of Vegetation, Levelling The Area With Existing Stone Metal 155 Providing Of Additional Stone Metal And Its Carriage And Laying In Outdoor Yard, This Including Breaking Of Stones Complete Job. 156 Cleaning Of Control Room, Removing Dirt & Dust From The Panels, Walls, Cleaning Of Fixtures ( For One Bank ) 157 Painting Of Internal / External Walls And Roof By Approved Brand Of Oil Based Distemper 158 Painting Of Door And Window Panels Of Control Room By Approved Brand Of Paint 159 Repairs & Renovation Of 11 Kv Vcb, By Way Of Replacement Of A ) Grid-Spout Assembly 160 B ) Replacement Of Damaged Cts Of Different Ratio Testing The Ct With The Help Of Primary Injection Set Fixing In Pannel, Fixing The Secondary Connection After Assessing The Load ( Complete Job ) 161 C ) Thorough Checking Of Control Wiring Circuits, Replacement Of Damaged Wire If Any, Replacement Of Terminal Plates, Tripping Circuits, Close / Trip Switch, Ammeter Switch, Replacement Of Voltmeter & Ammeter . 162 D ) Replacement Of 11 Kv Damaged Pt 163 E ) Replacement Of Blown Fuses, Checking The Pt Terminal With Respect Of 11 Kv Bus Bar Complete Job. 164 F ) Replacement Of Trip / Close Coil 165 G ) Replacement Of Trivector Meter On 11 / 33 / 66 Kv Panels 166 Installation, Testing And Commissioning , Replacement Of Lt Cabele 167 11 Kv Power Cables / 33 Kv Power Cables / 66 Kv Power Cablesa ) Identification Of Damaged Portion Of Cable, Tracing Of Cable, Remove Cable From Trench, Carriage And Laying Of Cable ( Complete Job ) Including Cleaning Of Cable Trenches. 168 B ) Replacement Of Damaged Cable Of Sizes 169 Replacementof Termination Kits Of Different Sizes, Connecting The Cable With Panel And Outgoing Structures After Crimping Of Lugs Fixing With Nuts And Bolts, Checking Of Earth Point, Connecting The Earthing Point Of Cable With Existing Earthing System A ) 11 Kv Indoor Termination Kit ( 1-Phase / 3 Phase ) 170 B ) 11 Kv Outdoor Termination Kit ( 1-Phase / 3 Phase ) 171 C ) 33 Kv Indoor Termination Kit ( Single Phase ) 172 D ) 33 Kv Outdoor Termination Kit ( Three Phase ) 173 E ) 33 Kv Indoor Termination Kit ( Three Phase ) 174 F ) 33 Kv Outdoor Termination Kit ( Single Phase ) 175 G ) 66 Kv Indoor Termination Kit ( Single Phase ) 176 H ) 66 Kv Outdoor Termination Kit ( Single Phase ) 177 Improvement Of Earthing System In Control Room By Way Of Replacement Of Earthing Risers From Earthing Point To Panel / Checking Of All Welding Points / Re-Welding Of Lose Connection, Laying Of Fresh / Additional Earth-Mat Strip To Improve The Existing Earthing System ( Complete One Panel Set ) 178 Checking Of Ir Values 179 De-Watering Of Receiving Station To Avoid Water Logging. 180 Repairing Of Electrical Circuits For Improvement Of Control Room Immunination, Power Points Etc ( Complete Job ) 181 Installation, Testing, Commissiing For Replacement Of Aux. Transformer At Receiving Station 182 On Site Repairing Of Aux Transformer For Missing Phase, Lt Strip, Lt Bush Rod, Lt Bush Cup, Ht Bush Rod Etc ( Complete Job ) 183 Transport Charges For Carriage Of T&P, Men & Material On Urgent Basis During Power Breakdown And Restoration Of System. ( Auto Carrier ) Aditional 1Km @ 90 / Per Km 184 Replacement Of Out Door Yard Lights Including Wiring System And Fixing Oflamps On Fixtures. 185 Marking Of EquipmentS, Sign Boards By Way Of Painting / Fixing Of Pvc Plates For Demarcation Of Different Equipment To Avoid Mishandling. 186 Replacement / Repair / Fixing Of Ceiling Fans At Receiving Station. 187 Replacement / Repair / Fixing Of Cooling Fans On Radiators Of Power Transformer To Avoid Heating. 188 Flash In 66Kv, 33 Kv & 11 Kv Panels Due To Overloading Moisture, Cleaning Of Carbonized Panel By Petrol / Cotton Cloth, Replacement Of Damaged / Worn-Out Lugs, Post Insulator, Bakelite Sheet, Arcing Chamber Panel Heaters Etc. 189 Repair Of Plaster Of Thickness 12 Mm To 20 Mm In Patches Of Areas 2.5 Sqm Meters And Under Including Cutting The Patch In Proper Shape And Preparing And Plastering The Surface Of The Walls Complete Incl. Disposal Of Rubbish To The Dumping Ground Within 50 M Leada ) With Cement Mortar 1:4 ( 1 Cement : 4 Fine / Coarse Sand ) 190 Cutting Of Large Tree Branches Falling Over 66 / 33 Lines And Coming Into The Corridor To Avoid Damages / Faults / Conductor Snapping. 191 Cleaning Of Cable Duct, Removing Of Duct Covers And Placing Back After Cleaning The Duct Including Disposal Of Rubbish Up To 50 Mtr Lead 192 Replacing Sand Store Slabs In Roofing, Laid Incement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) Including Necessary Repairs And Cement Painting With Same Mortar Complete, Including Disposal Of Rubbish To Dumping Ground Within 50 Meters Of Lead 193 Dismantling Doors, Windows And Clerestory Windows ( Steel Or Wood ) Shutter Including Chow Khats, Holdfast Etc. Complete And Stacking With 50 Mtr Lead 194 Providing And Fixing T-Iron Frames For Doors, Windows And Ventilators Of Mild Steel T-Sections, Joints Mitred And Welded, Including Fixing Of Necessary But Hinges And Screws And Applying A Priming Coat Of Approved Steel Primer ( Cc 1:3:6 ) 195 Demolishing Cement Concrete Manually / By Mechanical Means Including Disposal Of Material Within 50 Mtr 196 Cement Concrete 1:2:4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate ) 62 Mm Thick 197 Roof Top Treatment To Prevent Water Leakage Of Control Room 198 Repairing Of Receiving Station Mesh Fencing / Chain Link Mesh Fencing Height Upto 8Ft 199 Watering Of Earth Pits 200 Cleaning Of Acdc, Dbdc Board, Rtcc, Charger, Battery Bank, Solar Batteries, Other Alike Small Equipments ( Complete Job ) 201 Cleaning Of 66 / 33 Kv Crp Using Vacuum Cleaner From Inside With Proper Care, From Outside With Thinner / Varnish And Making 66 / 33 Kv Crp Vermic Proof. 202 Cleaning Of 11 Kv Panel Using Vacuum Cleaner From Inside With Proper Care, From Outside With Thinner / Varnish And Making It Vermic Proof To Avoid Rodent Faults. 203 Erection Of Channel Cross Arm Of Size 100X50x 6Mm , 10 Feet Long And Above Including Fixing Of Ms Flat Iron Clamps With Required Size Of Bolts Including Punching Of Bolts Complete 204 Erection Of Channel Cross Arm Of Size 100X50x 6Mm Up To 09 Feet Long Including Fixing Of Ms Flat Clamps With Required Size Of Bolts Including Punching Of Bolts Complete 205 Erection Of Angle Iron Braces Of Size 65X65x6 Mm, Fixing With Double Clamp Of Ms Flat Including Punching Of Bolts Of Ist Level To Level 3Rd In Cross Section Typeabove Up To 14Longcomplete 206 Erection Of Angle Iron Braces Of Size 65X65x6 Mm Along With Belts Of Same Size , Fixing With Double Clamp Of Ms Flat Including Punching Of Bolts Of Ist Level To Level 3Rd In Cross Section Type 6 And Above Upto 10Longcomplete 207 Erection Of Angle Iron Belts Of Size 50X50x 6 Mm Along With Belts Of Same Size , Fixing With Double Clamp Of Ms Flat Including Punching Of Bolts Of Ist Level To Level 3Rd In Cross Section Type Upto 10 Long 208 Erection Of Angle Ironof Size 65X65x6 Mmfixing With Double Clamp Of Ms Flat Including Punching Of Bolts Of Ist Level To Level 3Rd In Crossection Typeabove11 Long Complete For Guardnetting. 209 Flat Iron Ties 50X6 Mm Size 1 Feet Long Along With Fixing With Cross Arms 210 Erection Of 66 Kv Disc Insulator ( Polymer Type ) With Tension Fittings Including Punching Of Locking Pinscomplete 211 Erection Of 33 Kv Disc Insulator ( Polymer Type ) With Tension Fittings Including Punching Of Locking Pinscomplete 212 Erection Of 66 Kv Pin Insulator With Pins3 Nos On Top Of Cross Arm Including Fixing Of Ms Flat Ties To Rest It On , Punching Of Base Bolt / Locking Pin Complete 213 Erection Of 33 Kv Pin Insulator With Pins3 Nos On Top Of Cross Arm Including Fixing Of Ms Flat Ties To Rest It On , Punching Of Base Bolt / Locking Pin Complete 214 Erection Of Guy Rodincluding Digging Of Pit , Disposal Of Excavated Soil , Refilling Of Excavated Pits In Layers Of Stone Boulders And Fine Soil Including Fixing , Adjusting Properly Turn Buckle, Anchor Plate And Staining Screw Complete 215 Carriage At Site , Un-Bundling , Laying And Stringing Of Acsr Dog Conductor Including Making Of Small Bundles Of Conductor As Per Site Requirement, Cutting In Required Span Lengths Complete ( As Per Rec Standard ) 216 Erection Of Anti Climbing Devices At St Pole Along With Fixing / Cutting / Bending Of Barbed Wire, Fixing With Clamps 217 Erection Of Danger Plates 218 Route / Temp Path Clearance By Way Of Cleaning Bushes And Vegetation & Making Temp. Pathcutting & Filling For Carriage Of Line Material ( 400 Mx1mx0.2M ) = 80 Cum 219 Watch And Ward Of The Material And T&P Round The Clock I.E. 3 Shifts, Rate Of 1 Lab For 1 Shift 220 Route Clearance For Corridor Of 5 M 221 Installation, Testing And Commissioning Of 11Kv Panel Board With Vcb Incomer ( One No. ) 222 Installation, Testing And Commissioning Of 11Kv Panel Board With Vcb Outgoing ( One No. ) 223 Setting Of Stubs With Templates After Positioning And Leveling Of Templates Excluding Cost Of Foundations 224 Handling And Fabrication Of Material In Divisional Store, Fabrication Of Angle Iron Braces / Belts / Guard Netting Angles, Fencing Posts Etc From Angle Iron Of Sizes 225 Fabrication Of Guy Rods Complete Including Turn Buckle, Staining Screw, Anchor Plate, Thereading Of Guys And Staining Screw 226 Fabrication Of Channel Cross Arms Of Sorts From Ms Channel Of Sizes , Making Holes As Per Requirement, Punching Of Members And Numbering On Each Member, Grinding Of Sharp Edges And Uneven Surface Of Memebers And Painting Of Members With Red Oxide Paint. 227 Fabrication Of Ties, Clampsfrom Ms Flat ( Suitable For 9 Mts, 11Mts, 13Mts & 16 Mts Poles ) 228 Fabrication Of Earthing Plates , Cable Duct Coversfrom Ms Plate As Per Rec Drawings 229 Fabrication Of Earthing Spikes From Ms Tor Steel Of Sorts As Per Rec Drawings 230 Fabrication Of St Poles By Way Of Drilling Of Extra Holes 231 Fabrication Of Foundation Boltsfrom Ms Tor Steel Of Sorts Including Threading As Per Rec Drawings 232 Fabrication Of Earthing Pipe From Gi Pipe And Welding Of Earthing Plateas Per Rec Drawings 233 Fabrication Of Column Structures, Beam Structure, Isolator Structures, La , Ct, Pt And Pi Structures As Per Rec Drawings 234 Shifting Of Channel / Angle / Flat Iron At And Average Distance Of 50Mtr From Unloading Site To Site Of Stacking And Stacked Properly. 235 Shifting Of Channel / Angle / Flat Iron / Fabricated Material At And Average Distance Of 50Mtr For Making Space For Other Store Material And Its Stacking . 236 Unloading Of Pcc Poles 9 / 8 Mts . 237 Unloading Of Pcc Poles 11 Mts . 238 Unloading Of Pcc Poles 13 Mts . 239 Dragging / Shifting Of Pcc / St Pole At And Average Istance Upto 50 Mtr For Stacking To Accesible Place For Loading / Unloading Purpose And Its Satacking 240 Shifting Of Old / New Acsr Conductor At And Average Distance Of 50Mtr For Unloading Site To Site Of Stacking And Stacked Properlyand Also For Making Space For Other Store Material And Its Stacking .. 241 Unloading Of 11Kv Vcb Pannels ( 1+3 ) 242 Unloading Of 11Kv Vcb Pannels ( 1+4 ) . 243 Unloading Of 11Kv Vcb Pannels ( 1+5 ) . 244 Unloading Of 11Kv Vcb Pannels Ok / Damaged ( 1No ) . 245 Unloading Ofac Board / Dc Board / Battery Bank / Battery Charger 246 Unloading Of 33 / 66 Kv Vcb / C&R Pannel . 247 Shifting / Draggingof 11 / 33 / 66Kv Panel At An Average Distance Of 50Mtr For Making Space For Other Store Material And Its Stacking Also For Making Space For Other Store Material And Its Stacking . 248 Unloading Of Xlpe Cable 120 / 185 Mm² . 249 Unloading Of Xlpe Cable 240 / 300 Mm² . 250 Unloading Of Xlpe Cable 400 / 630 Mm² . 251 Shifting Of Xlpe Cable All Sizes At An Average Distance Of 50Mtr From Unloading Site To Site Of Stacking And Stacked Properly Also For Making Space For Other Store Material And Its Stacking ... 252 Unloading Of 66 / 33 / 11 Kv Cable Kits Of Different Sizes 253 Shifting Of 66 / 33 / 11 Cable Kits Of All Sizes At An Average Distance Of 50Mtr From Unloading Site To Site Of Stacking And Stacked Properly Also For Making Space For Other Store Material And Its Stacking ... 254 Unloading Of Guy / Gi Wire / Barbed Wire Including Carriage Towards Stacking Site And Stacked Porperly. 255 Unloading Of 11Kv New / Damaged Distributiontransformer. 256 Dragging Of 11Kv Transformer At An Average Distance Upto 50 Mtr For Stacking To Accesible Place For Loading / Unloading Purpose And Its Satacking 257 Unloading Oftransformer Oil Barrels. 258 Dragging Oftransformer Oil Old / New Barrel At An Average Distance Upto 50 Mtr For Stacking To Accesible Place For Loading / Unloading Purpose And Its Satacking Also For Making Space For Other Store Material And Its Stacking .. 259 Unloading Ofms Angle, Ms Channel, Ms Flate , Tar Steel 260 Unloading Of Hardware Items Such As Nuts And Bolts , Clamps Of Sorts, Washers, Welding Rods, Old Sarees, Chain Link Mesh, Pipe Etc . 261 Shifting Ofhardware Items Such As Nuts And Bolts , Clamps Of Sorts, Washers, Welding Rods, Old Sarees, Chain Link Mesh, Pipe Etc At An Average Distance Of 50Mtr For Making Space For Other Store Material And Its Stacking . 262 Unloading Of 33 / 11 Kv Disc Insulators. 263 Unloading Of 33 Kv Disc Fittings 264 Shiftingof 33 / 11Kv Disc Insulator At An Average Distance Upto 50 Mtr For Stacking To Accesible Place For Loading / Unloading Purpose And Its Satackingalso For Making Space For Other Store Material And Its Stacking .. . 265 Unloading Of 33 / 11 Kv Pin Insulators / Guy Insulator / G.I Pin. 266 Shiftingof 33 / 11Kv Pin Insulator / Guy / G.I Pinsat An Average Distance Upto 50 Mtr For Stacking To Accesible Place For Loading / Unloading Purpose And Also For Making Space For Other Store Material And Its Stacking. 267 Unloading Of Cement. 268 Shiftingofcement / Cement Block At An Average Distance Upto 50 Mtr For Stacking To Accesible Place For Loading / Unloading Purpose And Also For Making Space For Other Store Material And Its Stacking ... 269 Unloading Of 33 Kv Ct / Ptunit . 270 Shifting Of 33 Kv Ct / Pt At An Average Distance Of 50Mtr For Making Space For Other Store Material And Its Stacking . 271 Unloading Of 11 Kv Ct / Ptunit Includingcarriage Towards Stacking Site And Stacked Porperly. 272 Shiftingof 11 Kv Ct / Ptat An Average Distance Upto 50 Mtr For Stacking To Accesible Place For Loading / Unloading Purpose And Also For Making Space For Other Store Material And Its Stacking .. 273 Unloading Of 33 Kv Isolators. 274 Shiftingof 33Kv Issolatorsat An Average Distance Upto 50 Mtr For Stacking To Accesible Place For Loading / Unloading Purpose And Its Satackingand Also For Making Space For Other Store Material And Its Stacking . . 275 Unloading Of 33 / 66 Kv Las. 276 Shiftingof 33 / 66Kv Lasat An Average Distance Upto 50 Mtr For Stacking To Accesible Place For Loading / Unloading Purpose And Also For Making Space For Other Store Material And Its Stacking . 277 Unloading Of 11 Kv Las / Go / Hg / Issolator . 278 Shiftingof 11 Kv Las / Go / Hg / Issolator At An Average Distance Upto 50 Mtr For Stacking To Accesible Place For Loading / Unloading Purpose And Also For Making Space For Other Store Material And Its Stacking .. 279 Unloading Of Pvc Cable / Control Cable Of Different Sizeincludingcarriage Towards Stacking Site And Stacked Porperly. 280 Unloading Of Al Paint / Red Oxide Paint / Black Paintincludingcarriage Towards Stacking Site And Stacked Porperly. 281 Unloading Of 66Kvct / Pt / Isolator . 282 Shiftingof 66 Kv Ct / Pt / Isolator At An Average Distance Upto 50 Mtr For Stacking To Accesible Place For Loading / Unloading Purpose And Also For Making Space For Other Store Material And Its Stacking .. 283 Unloading Of T&P Items Like Drilling Machine, Chainpully , Pully Lifting Machine , Hand Drill Machine, Al Ladder, Welding Set, Tool Kit, Crimping Tooletc 284 Dismantling Of Old 11Kv Isolator Including Allied Equipments 285 Installation Of 11Kv Isolators 286 Shiftingof T&P / Testing / Safetyequipments At An Average Distance Upto 50 Mtr For Stacking To Accesible Place For Loading / Unloading Purpose And Also For Making Space For Other Store Material And Its Stacking .. 287 Unloading Of Filter Plant Heavy Duty 288 Shiftingof Filter Plantat An Average Distance Upto 50 Mtr For Stacking To Accesible Place For Loading / Unloading Purpose And Also For Making Space For Other Store Material And Its Stacking . 289 Loading Of Pcc Poles 9 / 8 Mtr 290 Loading Of Pcc Poles 11 Mtr 291 Loading Of Pcc Poles 13 Mtr 292 Loading Of Cement 293 Loading Of 11 Kv Vcb 1+3 Pannels 294 Loading Of 11 Kv Vcb 1+4 Pannels 295 Loading Of 11 Kv Vcb 1+5 Pannels 296 Loading Of 11 Kv Vcb 1 Pannel Ok / Damage 297 Loading Of Ac Board / Dc Board / Battery Charger / Battery Bank 298 Loading Of 33Kv Vcb 299 Loading Of 33Kv C&R Pannels 300 Loading Of Xlpe Cable 120 / 185 Mm² 301 Loading Of Xlpe Cable 240 / 300Mm² 302 Loading Of Xlpe Cable 400 / 630 Mm² 303 Loading Of Cable Kits Of Different Sizes 304 Loading Of Guy / Gi Wire / Barber Wire 305 Loading Of 11 Kv Distributiontransformer 306 Loading Of Transformer Oil Barrels 307 Loading Of Ms Angle Iron Braces, Ms Channel Cross Arms, Guy Rod, Earthing Spikes, Ms Flate 308 Loading Of Hardware Items Such As Nuts And Bolts, Clamps Of Sorts, Washers, Welding Rods, Old Sarees, Chain Link Mesh, Pipe 309 Loading Of 33 / 11Kv Disc Insulator 310 Loading Of 33 Kv Disc Fitting 311 Loading Of 33 / 11 Kv Pin Insulator / Guy Insulator / G.I Pin 312 Loading Of 33 Kv Isolator 313 Loading Of 33 Kv La 314 Loading Of 11Kv Isolators 315 Loading Of Pvc Cable / Control Cable Of Different Size Includingcarriage From Stacked Site. 316 Loading Ofal Paint / Red Oxide Paint / Black Paint 317 Loading Of66kvct / Pt / Isolator 318 Loading Of66kvc&R Pannel 319 Loading Of66kv Vcb Breaker Sf6 320 Loading Of66kv La 321 Loading Offilter Plant Heavy Duty 322 Carriageof Fabrication Column Structures, Beam Structure, Isolator Structures, La , Ct, Pt And Pi Structures Etc Towards Stacking Site And Stacked Properly 323 Loading Offabrication Column Structures, Beam Structure, Isolator Structures, La , Ct, Pt And Pi Structures Etcincludingcarriage From Stacked Site. 324 Loading Of 33 Kv Ct / Pt Units 325 Loading Of 11 Kv Ct / Pt Units 326 Loading Of T&P Items Like Drilling Machine, Chainpully , Pully Lifting Machine , Hand Drill Machine, Al Ladder, Welding Set, Tool Kit, Crimping Tooletc Units 327 Loading Of Testing Equipments Like Meggar, Earth Resitivitytester , Oil Testing Machine, Search Light, Turn Ratio Meter , Multimeter Etc Units 328 Loading Of Safetyequipments Like Safety Belts, Safety Shoes, Fire Extinguisher, Hand Gloves, Yard Lights , Led Bulbs , Rubber Mat , Etcunits 329 Shifting Of Allied Materials For Making Space For Porper Stacking Of Material 330 Carriageof Fabrication Material From Fabrication Site Towardsstacking Site And Proper Stacking Of Material. 331 Repair Of Store Shed By Way Of Replacement Of Damaged Cgi Sheets, Repair Of Cgi Sheets By Way Of Welding, Replacememt Of Hooks, Nuts And Bolts, Tightening Of Nuts Bolts And Hooks And Welding . 332 Collection Andcarriage Of T&P Items To Working Site And Back Crriage Of T&P After Job 333 Replacement Of Damaged Glass Panes 334 Replacement Of Damaged 66 / 33Kv PiS 335 Checking / Measuring / Inspection / Meggering Ofxlpe Cable / Control Cable By Way Of Unreal And After Work Agian Rereelingon Drum 336 Checking / Measuring / Inspection Ofacsr Conductorby Way Of Unreal And After Work Agian Re-Reelingon Drum 337 Complete Testing / Inspection Of Pannels Including Relay Testing , Interconnection, Charging Polarity Etc During Issue / Receipt / Verification. 338 Prototype Erection Of Gantry / Beam / Ct / Pt / Isolator Sturcture 339 Charges For Providing Highly Skilled Electrician / Fitter / Welder / Mason / Painter 340 Charges For Providingskilled Electrician / Fitter / Welder / Mason / Painter 341 Charges For Providingunskilled Labour
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 8
Jammu And Kashmir View Result →
21.
Power #8843536 Technical Bid
Rate Contract For Supply Of Electrical Spares And Minor Stores / Hardware Items For The Year 2021-22 - 1 Al. Alloy As Per Is: 617 Of 1975 Pg Clamps 3 Bolt Type Conforming To Is: 5561-1970 ( Amended Upto Date ) And Those Stipulated In Section-Iii Of This Tender Document Suitable For Acsr Zebra Conductor Having Bolts Hot Dip Galvanized Nuts And Washers Electro Galvanized And Current Carrying Capacity Equivalent To Ampacity Of Zebra Conductor. Likely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc / As Per Departmental Sample Provided. 2 Al. Alloy As Per Is: 617 Of 1975 T-Clamps 3 Bolt Type Conforming To Is: 5561-1970 ( Amended Upto Date ) And Those Stipulated In Section-Iii Of This Tender Document Suitable For Acsr Zebra Conductor Having Bolts Hot Dip Galvanized Nuts And Washers Electro Galvanized And Current Carrying Capacity Equivalent To Ampacity Of Zebra Conductor.Likely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc / As Per Departmental Sample Provided 3 Al. Alloy As Per Is: 617 Of 1975, Bi-Mettalic Ct Clamp ( Universal Take Off ) Conforming To Is: 5561-1970 ( Ammended Upto Date ) And Those Stipulated In Section-Iii Of This Tender Document Suitable For Acsr Zebra Conductor Having Bolts Hot Dip Galvanized Nuts And Washers Electro Galvanized And Current Carrying Capacity Equivalent To Ampacity Of Zebra Conductor With Ct Terminals Suitable For 132Kv / 33Kv Cts Of Makes / Ae Mumbai, Sct Gaziabad, Bhel, Vidhyut Control System Andhra, Mehru Bhiwadi / Laxshmi Engg Bhopal, Jyoti Etc Nlikely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc / As Per Departmental Sample Provided 4 Al. Alloy As Per Is: 617 Of 1975, Bi-Mettalic Isolator Pad Clamp ( Universal Take Off ) Conforming To Is: 5561-1970 ( Ammended Upto Date ) And Those Stipulated In Section-Iii Of This Tender Document Suitable For Acsr Zebra Conductor Having Bolts Hot Dip Galvanized Nuts And Washers Electro Galvanized And Current Carrying Capacity Equivalent To Ampacity Of Zebra Conductor With Pad Terminals Suitable For 132Kv / 33Kv Isolators Of East Land, Elpro, Hivelm Calcutta, S&S, Gr Power, Skipper, Bimco, Andhra Mech. Industries Etc Nlikely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc / As Per Departmental Sample Provided N 5 Al. Alloy As Per Is: 617 Of 1975, Bi-Mettalic Breaker Pad Clamp ( Universal Take Off ) Conforming To Is: 5561-1970 ( Ammended Upto Date ) And Those Stipulated In Section-Iii Of This Tender Document Suitable For Acsr Zebra Conductor Having Bolts Hot Dip Galvanized Nuts And Washers Electro Galvanized And Current Carrying Capacity Equivalent To Ampacity Of Zebra Conductor With Pad Terminals Suitable For 132Kv / 33Kv Breakers Of Sf 6 Type-Abb, Cgl, Siemens, Bhel / Vcb Type- S&S, Gec Alsthom, Bhel, Abb, Siemens, Megawin Etc. Nlikely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc / As Per Departmental Sample Provided N 6 Al. Alloy As Per Is: 617 Of 1975, Bi-Mettalic Ct Pad Clamp ( Universal Take Off ) Conforming To Is: 5561-1970 ( Ammended Upto Date ) And Those Stipulated In Section-Iii Of This Tender Document Suitable For Twin Acsr Zebra Conductor With Conductor Spacing 300Mm And Ct Terminal Spacing Of 140Mm Having Bolts Hot Dip Galvanized Nuts And Washers Electro Galvanized And Current Carrying Capacity Equivalent To Ampacity Of Twin Zebra Conductor With Pad Terminals Suitable For 132Kv / 33Kv Cts Of Ae Mumbai, Sct Gazaibad, Bhel, Vidhyut Control Andhra, Mehru Bhiwadi / Laxmi Engg Bhopal Vidhyut Control Andhra, Jyoti Etc Nlikely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc / As Per Departmental Sample Provided 7 Al. Alloy As Per Is: 617 Of 1975, Bi-Mettalic Twin Isolator Pad Clamp ( Universal Take Off ) Conforming To Is: 5561-1970 ( Ammended Upto Date ) And Those Stipulated In Section-Iii Of This Tender Document Suitable For Twin Acsr Zebra Conductor With Conductor Spacing 300Mm And Isolator Pad Clamp Terminal Spacing Of 140Mm Having Bolts Hot Dip Galvanized Nuts And Washers Electro Galvanized And Current Carrying Capacity Equivalent To Ampacity Of Twin Zebra Conductor With Pad Terminals Suitable For 132Kv / 33Kv Isolator Of East Land, Elpro, Hivelm Calcutta, S&S, Gr Power, Skipper, Bimco. Nlikely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc / As Per Departmental Sample Provided N 8 Al. Alloy As Per Is: 617 Of 1975, Bi-Mettalic Breaker Pad Clamp ( Universal Take Off ) Conforming To Is: 5561-1970 ( Ammended Upto Date ) And Those Stipulated In Section-Iii Of This Tender Document Suitable For Twin Acsr Zebra Conductor With Conductor Spacing 300Mm Breaker Terminal Spacing 140Mm Having Bolts Hot Dip Galvanized Nuts And Washers Electro Galvanized And Current Carrying Capacity Equivalent To Ampacity Of Twin Zebra Conductor With Pad Terminals Suitable For 132Kv / 33Kv Breaker Of Type Sf6-Cgl, Abb, Siemens, Bhelvcb-S&S, Gec Alstom, Bhel, Abb Siemens Megawin Likely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc / As Per Departmental Sample Provided N 9 Al. Alloy As Per Is: 617 Of 1975 Pg Clamps Conforming To Is: 5561-1970 ( Ammended Upto Date ) And Those Stipulated In Section-Iii Of This Tender Document Suitable For Acsr Panther Conductor Having Bolts Hot Dip Galvanized Nuts And Washers Electro Galvanized And Current Carrying Capacity Equivalent To Ampacity Of Panther Conductor Nlikely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc / As Per Departmental Sample Provided N 10 Al. Alloy As Per Is: 617 Of 1975 T- Clamps Conforming To Is: 5561-1970 ( Ammended Upto Date ) And Those Stipulated In Section-Iii Of This Tender Document Suitable For Acsr Panther Conductor Having Bolts Hot Dip Galvanized Nuts And Washers Electro Galvanized And Current Carrying Capacity Equivalent To Ampacity Of Panther Conductor Nlikely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc / As Per Departmental Sample Provided 11 Al. Alloy As Per Is: 617 Of 1975 T- Clamps Conforming To Is: 5561-1970 ( Ammended Upto Date ) And Those Stipulated In Section-Iii Of This Tender Document Suitable For Acsr Panther Conductor Having Bolts Hot Dip Galvanized Nuts And Washers Electro Galvanized And Current Carrying Capacity Equivalent To Ampacity Of Panther Conductor Nlikely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc / As Per Departmental Sample Provided Al. Alloy As Per Is: 617 Of 1975 T- Clamps Conforming To Is: 5561-1970 ( Ammended Upto Date ) And Those Stipulated In Section-Iii Of This Tender Document Suitable For Acsr Panther Conductor Having Bolts Hot Dip Galvanized Nuts And Washers Electro Galvanized And Current Carrying Capacity Equivalent To Ampacity Of Panther Conductor Nlikely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc / As Per Departmental Sample Provided N 12 Al. Alloy As Per Is: 617 Of 1975, Bimetallic Isolator Pad Clamp ( Universal Take Off ) Conforming To Is: 5561-1970 ( Ammended Upto Date ) And Those Stipulated In Section-Iii Of This Tender Document Suitable For Acsr Panther Conductor Having Bolts Hot Dip Galvanized Nuts And Washers Electro Galvanized And Current Carrying Capacity Equivalent To Ampacity Of Panther Conductor With Pad Terminals Suitable For 132 / 33Kv Isolators Of East Land, Elpro, Hivelm Calcutta, S&S, Gr Power, Skipper, Bimco. Nlikely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc / As Per Departmental Sample Provided N 13 Al. Alloy As Per Is: 617 Of 1975, Bimetallic Breaker Pad Clamp ( Universal Take Off ) Conforming To Is: 5561-1970 ( Ammended Upto Date ) And Those Stipulated In Section-Iii Of This Tender Document Suitable For Acsr Panther Conductor Having Bolts Hot Dip Galvanized Nuts And Washers Electro Galvanized And Current Carrying Capacity Equivalent To Ampacity Of Panther Conductor With Pad Terminals Suitable For 132Kv / 33Kv Breaker Of Sf6 – Cgl, Abb, Siemens , Bhel Vcb- S&S, Gec Alstom, Bhel, Abb, Siemens, Megawin Likely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc / As Per Departmental Sample Provided 14 Al. Alloy As Per Is: 617 Of 1975, Bimetallic Ct Pad Clamp ( Universal Take Off ) Conforming To Is: 5561-1970 ( Ammended Upto Date ) And Those Stipulated In Section-Iii Of This Tender Document Suitable For Twin Panther Conductor With Conductor Spacing 300Mm And Ct Terminal Spacing Of 140Mm Having Bolts Hot Dip Galvanized Nuts And Washers Electro Galvanized And Current Carrying Capacity Equivalent To Ampacity Of Twin Panther Conductor With Pad Terminals Suitable For 132Kv / 33Kv Cts Of Ae Mumbai, Sct Gaziabad, Bhel, Vidhyut Control System Andhra, Lakshmi Bhopal, Mehru Bhiwadi, Jyoti Nlikely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc / As Per Departmental Sample Provided 15 Al. Alloy As Per Is: 617 Of 1975, Bi-Mettalic Isolator Pad Clamp ( Univercial Take Off ) Conforming To Is: 5561-1970 ( Ammended Upto Date ) And Those Stipulated In Section-Iii Of This Tender Document Suitable For Twin Panther Conductor With Conductor Spacing 300Mm And Isolator Terminal Spacing Of 140Mm Having Bolts Hot Dip Galvanized Nuts And Washers Electro Galvanized And Current Carrying Capacity Equivalent To Ampacity Of Twin Panther Conductor With Pad Terminals Suitable For 132Kv / 33Kv Isolator Of Estland, Elpr, Hivelm Calcutta, S&S, Gr Power, Skipper, Bimco, Andhra Mech. Ind, Nlikely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc / As Per Departmental Sample Provided N 16 Al. Alloy As Per Is: 617 Of 1975, Bimetallic Breaker Pad Clamp ( Universal Take Off ) Conforming To Is: 5561-1970 ( Ammended Upto Date ) And Those Stipulated In Section-Iii Of This Tender Document Suitable For Twin Panther Conductor With Conductor Spacing 300Mm And Terminal Spacing Of 140Mm Having Bolts Hot Dip Galvanized Nuts And Washers Electro Galvanized And Current Carrying Capacity Equivalent To Ampacity Of Twin Panther Conductor With Pad Terminals Suitable For 132Kv / 33Kv Breaker Of Sf6- Cgl, Abb, Siemns Bhel Vcb-S&S, Gec Alstom, Bhel, Abb Siemens, Megawin , Likely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc / As Per Departmental Sample Provided 17 Al. Alloy As Per Is: 617 Of 1975 Pg Clamps 3 Bolt Type Conforming To Is: 5561-1970 ( Amended Upto Date ) And Those Stipulated In Section-Iii Of This Tender Document Suitable For Acsr Zebra-Acsr Panther Conductor Having Bolts Hot Dip Galvanized Nuts And Washers Electro Galvanized And Current Carrying Capacity Equivalent To Ampacity Of Zebra Conductor. Nlikely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc / As Per Departmental Sample Provided N 18 Al. Alloy As Per Is: 617 Of 1975 T-Clamps 3 Bolt Type Conforming To Is: 5561-1970 ( Amended Upto Date ) And Those Stipulated In Section-Iii Of This Tender Document Suitable For Acsr Zebra-Acsr Panther Conductor Having Bolts Hot Dip Galvanized Nuts And Washers Electro Galvanized And Current Carrying Capacity Equivalent To Ampacity Of Zebra Conductor. Nlikely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc / As Per Departmental Sample Provided N 19 P.I Clamp For Acsr Zebra Conductor 20 P.I Clamp For Acsr Panther Conductor 21 Single Suspension Hardware Fitting For Zebra Conductor Conforming To Is 2486 ( Part-I ) Ammended Upto Date And The Specification Stipulated In Sec. Iii Of This Tender Document Having Suspension Clamp Of Al Alloy Grade-A6 ( Is: 617-1975 ) , Ferrous Parts Hot Dip Galvanized ( Is: 2633 1986 ) Suitable For 16Mm B&S 70Kn Disc Insulators., Ultimate Tensile Strength Of ( H / W ) 7000Kg Nlikely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc / As Per Departmental Sample Provided Na. Station Type Nb. Line Type 22 Single Tension Hardware Fitting For Acsr Zebra Conductor Conforming To Is 2486 ( Part-I ) Ammended Upto Date ) And The Specification Stipulated In Sec. Iii Of This Tender Document Having Tension Clamp Of Al Alloy Grade-A6 ( Is: 617-1975 ) , Ferrous Parts Hot Dip Galvanized ( Is: 2633 1986 ) Suitable For 20Mm B&S 120Kn Disc Insulators., Nuts Of Hardware = 900Kg Nuts / Slip Strength Of Clamp = 95% Of Uts Of Conductor N = 8550 Kg Nlikely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc / As Per Departmental Sample Provided Na. Station Type Nb. Line Type N 23 Double Suspension Hardware Fitting For Zebra Conductor Conforming To Is 2486 ( Part-I ) Ammended Upto Date ) And The Specification Stipulated In Sec. Iii Of This Tender Document Having Suspension Clamp Of Al Alloy Grade-A6 ( Is: 617-1975 ) , Ferrous Parts Hot Dip Galvanized ( Is: 2633 1986 ) Suitable For 16Mm B&S 70Kn Disc Insulators., Nuts Of Hardware =7000Kg Nlikely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc / As Per Departmental Sample Provided Na. Station Type Nb. Line Type 24 Double Tension Hardware Fitting For Zebra Conductor Conforming To Is 2486 ( Part-I ) Ammended Upto Date And The Specification Stipulated In Sec. Iii Of This Tender Document Having Tension Clamp Of Al Alloy Grade-A6 ( Is: 617-1975 ) , Ferrous Parts Hot Dip Galvanized ( Is: 2633 1986 ) Suitable For 20Mm B&S 120Kn Disc Insulators., Nuts Of Hardware = 9000Kg Nuts / Slip Strength Of Clamp = 95% Uts Of Conductor N = 8550 Kg Nlikely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc / As Per Departmental Sample Provided Na. Station Type Nb. Line Type 25 Single Tension Fitting For Acsr Twin Zebra Conductor Conforming To Is 2486 ( Part-I ) Ammended Upto Date And The Specification Stipulated In Sec. Iii Of This Tender Document Having Tension Clamp Of Al Alloy Grade-A6 ( Is: 617-1975 ) , Ferrous Parts Hot Dip Galvanized ( Is: 2633 1986 ) Suitable For 20Mm B&S 120Kn Disc Insulators., Nuts Of Hardware = 9000Kg Nuts / Slip Strength Of Clamp = 95% Uts Of Conductor N = 8550 Kg Nlikely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc / As Per Departmental Sample Provided Na. Station Type Nb. Line Type 26 Single Suspension Fitting For Acsr Twin Zebra Conductor Conforming To Is 2486 ( Part-I ) Ammended Upto Date And The Specification Stipulated In Sec. Iii Of This Tender Document Having Tension Clamp Of Al Alloy Grade-A6 ( Is: 617-1975 ) , Ferrous Parts Hot Dip Galvanized ( Is: 2633 1986 ) Suitable For 20Mm B&S 120Kn Disc Insulators., Nuts Of Hardware = 9000Kg Nuts / Slip Strength Of Clamp = 95% Uts Of Conductor N = 8550 Kg Nlikely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc / As Per Departmental Sample Provided Na. Station Type Nb. Line Type 27 Single Suspension Hardware Fitting For Aaac Panther Conductor 37 / 3.15Mm Conforming To Is 2486 ( Part-I ) Amended Upto Date And The Specification Stipulated In Sec. Iii Of This Tender Document Having Tension Clamp Of Al Alloy Grade-A6 ( Is: 617-1975 ) , Ferrous Parts Hot Dip Galvanized ( Is: 2633 1986 ) Suitable For 16Mm B&S 70Kn Disc Insulators., Nuts Hardware =7000Kg Nlikely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc / As Per Departmental Sample Provided N 28 Single Tension Hardware Fitting For Aaac Panther Conductor 37 / 3.15Mm Conforming To Is 2486 ( Part-I ) Amended Upto Date ) And The Specification Stipulated In Sec. Iii Of This Tender Document Having Tension Clamp Of Al Alloy Grade-A6 ( Is: 617-1975 ) , Ferrous Parts Hot Dip Galvanized ( Is: 2633 1986 ) Suitable For 20Mm B&S 120Kn Disc Insulators., Nuts Hardware = 900Kg Nuts / Slip Strength Of Clamp = 95% Of Uts Of Conductor N = 8550Kg Nlikely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc / As Per Departmental Sample Provided N 29 Double Suspension Hardware Fitting For Aaac Panther Conductor 37 / 3.15Mm Conforming To Is 2486 ( Part-I ) Amended Upto Date ) And The Specification Stipulated In Sec. Iii Of This Tender Document Having Tension Clamp Of Al Alloy Grade-A6 ( Is: 617-1975 ) , Ferrous Parts Hot Dip Galvanized ( Is: 2633 1986 ) Suitable For 16Mm B&S 70Kn Disc Insulators., Nuts Of Hardware = 7000Kg Nlikely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc / As Per Departmental Sample Provided N 30 Double Suspension Hardware Fitting For Aaac Panther 37 / 3.15Mm Conductor Conforming To Is 2486 ( Part-I ) Amended Upto Date And The Specification Stipulated In Sec. Iii Of This Tender Document Having Tension Clamp Of Al Alloy Grade-A6 ( Is: 617-1975 ) , Ferrous Parts Hot Dip Galvanized ( Is: 2633 1986 ) Suitable For 16Mm B&S 70Kn Disc Insulators., Nuts Of Hardware = 7000Kg Nlikely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc / As Per Departmental Sample Provided 31 Single Tension Fitting For Acsr Twin Panther Conductor Conforming To Is 2486 ( Part-I ) Ammended Upto Date And The Specification Stipulated In Sec. Iii Of This Tender Document Having Tension Clamp Of Al Alloy Grade-A6 ( Is: 617-1975 ) , Ferrous Parts Hot Dip Galvanized ( Is: 2633 1986 ) Suitable For 20Mm B&S 120Kn Disc Insulators., Nuts Of Hardware = 9000Kg Nuts / Slip Strength Of Clamp = 95% Uts Of Conductor N = 8550 Kg Nlikely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc / As Per Departmental Sample Provided Na. Station Type Nb. Line Type N 32 Single Suspension Fitting For Acsr Twin Panther Conductor Conforming To Is 2486 ( Part-I ) Ammended Upto Date And The Specification Stipulated In Sec. Iii Of This Tender Document Having Tension Clamp Of Al Alloy Grade-A6 ( Is: 617-1975 ) , Ferrous Parts Hot Dip Galvanized ( Is: 2633 1986 ) Suitable For 20Mm B&S 120Kn Disc Insulators., Nuts Of Hardware = 9000Kg Nuts / Slip Strength Of Clamp = 95% Uts Of Conductor N = 8550 Kg Nlikely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc / As Per Departmental Sample Provided Na. Station Type Nb. Line Type N 33 Compression Type Repair Sleeve Suitable For Aaac / Panther Of 37 / 3.15Mm Designation With Body And Keeper Made Of Aluminum Alloy For Providing Reinforcement Of Conductor With Broken / Damaged Aluminum Strands. Repair Sleeve Should Conform To Is: 2121 / 1981 ( With Latest Amendments Up To Date ) And Should Present A Smooth Surface After Compression Nmin Failing Load = 95% Uts Of Conductor N = 7654Kg Ncompression Pressure = 100Tons For Al Nelectrical Resistance At 20Oc =75% Of Measured Resistance Of N Equivalent Length Of Conductor Ncorona Formation Voltage = 110% Of Max Line To Ground Voltage N 34 Compression Type Repair Sleeve Suitable For Aaac / Panther Of 37 / 2.88Mm Designation With Body And Keeper Made Of Aluminum Alloy For Providing Reinforcement Of Conductor With Broken / Damaged Aluminum Strands. Repair Sleeve Should Conform To Is: 2121 / 1981 ( With Latest Amendments Up To Date ) And Should Present A Smooth Surface After Compression Nmin Failing Load = 95% Uts Of Conductor N = 6144Kg Ncompression Pressure = 100Tons For Al Nelectrical Resistance At 20Oc =75% Of Measured Resistance Of N Equivalent Length Of Conductor Ncorona Formation Voltage = 110% Of Max Line To Ground N Voltage N 35 4R Stock Bridge Type Vibration Damper Suitable For Aaac / Panther ( Of 37 / 3.15Mm Designation ) Of Approved Design. The Clamps And Keeper Of The Vibration Damper Shall Be Made To Al Alloy So Designed As To Prevent Any Damage To Or Chafting Of The Conductor, During Erection Or Continued Operation. Clamping Bolts, Washers Should Of Mild Steel / Hdg Provided With Self Locking Nuts Designed To Prevent Corrosion Of The Threads. All Ferrous Parts Including The Messenger Cable Shall Be Hot Dip Galvanized ( Is 2633 ) . The Ends Of Messenger Cable Shall Be Effectively Sealed To Prevent Corrosion. Spring Washers Should Be Electro Galvanized Dampers Mass Should Be Of Cast Iron Hdg Conforming To Is 9708 Of 1980 Ntotal Wt Of The Item Shall Be = 2.4Kg Nslip Strength = 2.5Kn Before Fatigue Test Nslip Strength = 2.0Kn After Fatigue Test 36 4R Stock Bridge Type Vibration Damper Suitable For Aaac / Panther ( Of 37 / 2.88Mm Designation ) Of Approved Design. The Clamps And Keeper Of The Vibration Damper Shall Be Made To Al Alloy So Designed As To Prevent Any Damage To Or Chafting Of The Conductor During Erection Or Continued Operation. Clamping Bolts, Washers Should Of Mild Steel / Hdg Provided With Self Locking Nuts Designed To Prevent Corrosion Of The Threads. All Ferrous Parts Including The Messenger Cable Shall Be Hot Dip Galvanized ( Is 2633 ) . The Ends Of Messenger Cable Shall Be Effectively Sealed To Prevent Corrosion. Spring Washers Should Be Electro Galvanized Dampers Mass Should Be Of Cast Iron Hdg Conforming To Is 9708 Of 1980 Ntotal Wt Of The Item Shall Be = 2.4Kg Nslip Strength = 2.5Kn Before Fatigue Test Nslip Strength = 2.0Kn After Fatigue Test N 37 Mid Span Compression Joint For Panther / Aaac ( Of 37 / 3.15Mm Designation ) Suitable For Making Joints In The Conductor So Designed That On Installation No Air Space Is Left Within The Finished Joint. The Al Sleeve Used Should Be Of Extruded Al Tube Of Purity Not Less Than 95% While As Steel Sleeve Should Of High Strength Steel. Ni- Minimum Failing Load = 95% Uts Of Conductor N ( Slip Strength ) = 7654Kg Nii-Material N Outer Sleeve = Extruded Al Tube Of 99.5 % N Purity N Inner Sleeve = High Tensile Steel Niii- Elect Resistance At 20Oc = 75% Of Measured Resistance Of N Equivalent Length Of Conductor Niv- Ferrous Parts = Hot Dip Galvanized Nv -Compression Rate = 100Ton For Ac 38 Mid Span Compression Joint For Panther / Aaac ( Of 37 / 2.88Mm Designation ) Suitable For Making Joints In The Conductor So Designed That On Installation No Air Space Is Left Within The Finished Joint. The Al Sleeve Used Should Be Of Extruded Al Tube Of Purity Not Less Than 95% While As Steel Sleeve Should Of High Strength Steel. Ni- Minimum Failing Load = 95% Uts Of Conductor N ( Slip Strength ) = 6411Kg Nii- Material N Outer Sleeve = Extruded Al Tube Of 99.5 % N Purity N Inner Sleeve = High Tensile Steel Niii- Elect Resistance 20Oc = 75% Of Measured Resistance Of N Equivalent Length Of Conductor Niv Ferrous Parts = Hot Dip Galvanized Nv Compression Rate = 100Ton For Ac N 39 Armour Rods Helically Twisted Suitable For Acsr Panther / Aaac Panther To Provide Rigidity And Protection To The Conductor At All Suspension Parts And Also To Eliminate The Fatigue On The Conductor Due To Vibration And Corona. Ntype Performed Nmaterial Al / Alalloy Npurity Of Al Ec Grade 95.5% Ncorona Formation 110% Of Max Line To N Ground Voltage Nconsilic Strength 35Kg / Mm2 Nslip Strength 25% Uts Of Conductor Nends Ball Ended Nerection Of Lay Of Rods Right Hand Lay N 40 Compression Type Repair Sleeve Suitable For Acsr Zebra Conductor Of 54 / 7 / 3.18Mm Designation With Body And Keeper Made Of Aluminum Alloy For Providing Reinforcement Of Conductor With Broken / Damaged Aluminum Strands. Repair Sleeve Should Conform To Is: 2121 / 1981 ( With Latest Amendments Up To Date ) And Should Present A Smooth Surface After Compression Nmin Failing Load = 95% Uts Of Conductor N = 7654Kg Ncompression Pressure = 100Tons For Al Nelectrical Resistance At 20Oc =75% Of Measured Resistance Of N Equivalent Length Of Conductor Ncorona Formation Voltage = 110% Of Max Line To Ground Voltage N 41 4R Stock Bridge Type Vibration Damper Suitable For Acsr Zebra ( Of 54 / 7 / 3.18Mm Designation ) Of Approved Design. The Clamps And Keeper Of The Vibration Damper Shall Be Made To Al Alloy So Designed As To Prevent Any Damage To Or Chafting Of The Conductor, During Erection Or Continued Operation. Clamping Bolts, Washers Should Of Mild Steel / Hdg Provided With Self Locking Nuts Designed To Prevent Corrosion Of The Threads. All Ferrous Parts Including The Messenger Cable Shall Be Hot Dip Galvanized ( Is 2633 ) . The Ends Of Messenger Cable Shall Be Effectively Sealed To Prevent Corrosion. Spring Washers Should Be Electro Galvanized Dampers Mass Should Be Of Cast Iron Hdg Conforming To Is 9708 Of 1980 Ntotal Wt Of The Item Shall Be = 2.4Kg Nslip Strength = 2.5Kn Before Fatigue Test Nslip Strength = 2.0Kn After Fatigue Test 42 Mid Span Compression Joint For Acsr Zebra ( Of 54 / 7 / 3.18Mm Designation ) Suitable For Making Joints In The Conductor So Designed That On Installation No Air Space Is Left Within The Finished Joint. The Al Sleeve Used Should Be Of Extruded Al Tube Of Purity Not Less Than 95% While As Steel Sleeve Should Of High Strength Steel. Ni- Minimum Failing Load = 95% Uts Of Conductor N ( Slip Strength ) = 7654Kg Nii-Material N Outer Sleeve = Extruded Al Tube Of 99.5 % N Purity N Inner Sleeve = High Tensile Steel Niii- Elect Resistance At 20Oc = 75% Of Measured Resistance Of N Equivalent Length Of Conductor Niv- Ferrous Parts = Hot Dip Galvanized Nv -Compression Rate = 100Ton For Ac N 43 Armour Rods Helically Twisted Suitable For Acsr Zebra To Provide Rigidity And Protection To The Conductor At All Suspension Parts And Also To Eliminate The Fatigue On The Conductor Due To Vibration And Corona. Ntype Performed Nmaterial Al / Alalloy Npurity Of Al Ec Grade 95.5% Ncorona Formation 110% Of Max Line To N Ground Voltage Nconsilic Strength 35Kg / Mm2 Nslip Strength 25% Uts Of Conductor Nends Ball Ended Nerection Of Lay Of Rods Right Hand Lay N 44 Shunt Tripping Coil 110V Dc, 1A Suitable For 33Kv Vcb Of Bhel, Abb, Gec Alstom, Siemens, Mega Win, S&S Make 45 Spring / Charging / Closing Coil 110V, 1A Dc Suitable For 33Kv Vcb Of Bhel, Abb, Gec Alstom, Siemens, Mega Win, S&S Make 46 Male Contact Of 33Kv Bocb Of Bhel Make 47 Female Contact Of 33Kv Bocb Of Bhel Make 48 33Kv Vacuum Interrupter Suitable For 33Kv Vcb Of Bhel, Abb, Gec Alstom, Siemens, Mega Win, S&S Make 49 Sf-6 Gas Cylinder Of 9Kg 50 Arcing Chamber With Female Contact For 33Kv Bocb Bhel Make 51 Arcing Chamber Without Female Contact For 33Kv Bocb Bhel, Abb, Gec Alstom, Siemens, Mega Win, S&S Make 52 Thermal Overload Relay “Siemens Make” With Range 0.8-1.2Amp 53 Thermal Overload Relay “Siemens Make” Of 4A Max With Range 0.8-1Amp And 1.5A-1.2A 54 Mn2 Thermal Overload Relay With Start And Off / Reset Relay Of Range 0.9-1.5A L&T Make 55 Auxiliary Air Break Contactor Of Ac2 / Ac 3 Duty Cycle Nnumber Of Poles 3No. Nvoltage 415V Namp 0-2A Ncontacts 2No +2Nc Nmake Siemens N 56 Magnetic Control Contactor Nmake Andrew Yule Npower 44W Nvolt 110V Dc Nith 10A Nis 13947 Niec 947 N N 57 Thermal Overload Relay “Siemens Make” Of 4A Max With Range 0.8-1Amp And 1.5A-1.2A 58 Isolator Jaws Suitable For 33Kv Isolator Makes Eastland, Elpro, Hivelem Calcutta, S&S, Gr Power, Skipper, Bimco 59 Digital Oti 90-250V Ac / Dc, Range 0-150Oc Make Precimeasure Control Banglore 60 Digital Wti Meter Make Precimeasure Control Banglore 61 Hrc Fuse 2, 4, 6, 10Amps 62 Indicating Pygmy Lamp 110V Dc, Pin Type / Screw Type 63 10A 110V Ac / Dc Multi-Colour Led Indicators Lamps 64 110Volt Dc Alarm Buzzer Suitable For C&R Panel 65 Numerical Master Tripping Relay Nmake Easun Reyrolle Nmodel B- 24 Npoles 1No Nvolt 110V Dc Namp 1A Nnumerical Master Tripping Relay Nmake Easun Reyrolle Nmodel B- 24 Npoles 1No Nvolt 110V Dc Namp 1A N 66 Numerical Master Tripping Relay Nmake Easun Reyrolle Nmodel B- 86 Npoles 1No Nvolt 110V Dc Namp 1A N 67 Numerical O / C And E / F Relay Nmake Easun Reyrolle Nmodel Mit 114 Npoles 4Nos Nvolt 43- 280V Dc Namp 1A N 68 33Kv Voltage Grade, 3 Phase, 4 Wire Digital Trivector Energy Meter Nvolt 33Kv / V3 / 11V / V3 Nfrequency 50Hz Nrating - / 1A Naccuracy Class 0.5S Nstandard Is 14697 N Iec 62053-22 N 69 132Kv Voltage Grade, 3 Phase, 4 Wire Digital Trivector Energy Meter Nvolt 132Kv / V3 / 11V / V3 Nfrequency 50Hz Nrating - / 1A Naccuracy Class 0.5S Nstandard Is 14697 N Iec 62053-22 N 70 Lt Whole Current Trivector Meter 3X240 Volt, 50Hz 3 Phase 4 Wire 10-10Amp ( Secure Make ) 71 2 Pole Heavy Duty Rotary Switch With “Off” 5Amp Make “Key Cee” Equivalent Etc For C&R Panel 72 Auxiliary Contactor Switch For 33Kv Vcb Of Different Makes Bhel, Abb, Siemens, Megawin, . S&S, Gec Alsthom. 73 Semaphore Indicators For Isolators & Earth Switches 74 Miscellinious Items 75 Single Core 300Sq Mm 33Kv Heat Shrinkable Cable Kit Outdoor Type Nlikely Make M Seal, Powertech, H- Seal, Universal Etc N 76 Single Core 300Sq Mm 33Kv Heat Shrinkable Cable Kit Indoor Type Likely Make M Seal, Powertech, H- Seal, Universal Etc 77 Single Core 630Sq Mm 33Kv Heat Shrinkable Cable Kit Outdoor Type Nlikely Make M Seal, Powertech, H- Seal, Universal Etc N 78 Single Core 630Sq Mm 33Kv Heat Shrinkable Cable Kit Indoor Type Nlikely Make M Seal, Powertech, H- Seal, Universal Etc N 79 Single Core 630Sq Mm 33Kv Voltage Grade, Al. Conductor, Pvc Insulated, Sheathed, Armoured, Xlpe Cable Nlikely Make Havells Etc N 80 Shunt Capacitor Fuse 40A With Spring Complete Assembly 81 Transformer Oil Is 335 Of 1993 N N 82 Silcagel Crystal Size 8- 8 Mesh 83 Gi Nuts And Bolts Of Sorts ( 16Mmx35mm / 40Mm / 45Mm / 50Mm & 65Mm ) Heavy Duty As Per Sample 84 Gi Nuts And Bolts Of Sorts ( 10Mmx50mm ) Heavy Duty As Per Sample 85 Gi Nuts And Bolts Of Sorts ( 12Mmx50mm ) Heavy Duty As Per Sample 86 Spring Washers 16Mm Heavy Duty As Per Sample 87 Al Tape 88 Old Cotton Saree 89 33Kv Isolator Without Earthing Blade 1600Amp Isolator Clamp For Zebra N N 90 Grease 91 33Kv Isolator With Earthing Blade 1600Amp Isolator Clamp For Zebra Complete 92 Dcp Type Fire Fighting Equipment Of , 10, , Kg Capacity 93 Dcp Type Fire Fighting Equipment Of 25Kg Capacity 94 Dcp Type Fire Fighting Equipment Of 50Kg Capacity 95 Abc Type Fire Fighting Equipment Of 5, Kg Capacity 96 Abc Type Fire Fighting Equipment Of 10 Kg Capacity 97 12 Volt, 150 / 200Ah, 110Volt Dc Vrla Type Cells Make Hbl Etc 98 2 Volt, 200Ah, 110Volt Dc Lmla Type Cells Make Is Etc N N 99 Welding Electrodes Swg 8No As Per Is: 814 Of 2004 100 Welding Electrodes Swg 10No As Per Is: 814 Of 2004 101 G. I Wire Swg No. 8 / 4.06Mm Dia 102 Galvanized Steel Earth Wire Conforming To Acsr Core Wire As Per Is; 398 ( Ii ) - 1976 Na. Stranding & Wire Dia 7 / 3.66Mm Nb. No. Of Strands N Steel Core 1 N Outer Steel Layer 6 N 103 Led Lamp 12 Watt ( Philips, Havells, Crompton, Bajaj Make ) 104 Led Lamp 20 Watt ( Philips, Havells, Crompton, Bajaj Make ) 105 Led Lamp 45 Watt ( Philips, Havells, Crompton, Bajaj Make ) N N 106 Led Lamp 30 Watt ( Philips, Havells, Crompton, Bajaj Make ) N N 107 Search Light With 300-500Mtr. Focus Make Flash, Equivalent Etc 108 Led Street Light Fitting 40 / 45 Watt ( Philips, Syska, Havells, Crompton, Bajaj Make ) N N N 109 Led Street Light Fitting 60 / 70 Watt ( Philips, Syska, Havells, Crompton, Bajaj Make ) 110 Led Street Light Fitting 90 / 100 Watt ( Philips, Syska, Havells, Crompton, Bajaj Make ) 111 Single Core 300Sq Mm 33Kv Heat Shrinkable Cable Kit Outdoor Type Nlikely Make Raychem Make N 112 Single Core 300Sq Mm 33Kv Heat Shrinkable Cable Kit Indoor Type Likely Make Raychem Make 113 Twin Bush Clamp For Moose 114 Mcb 16-32 Amp ( Havells, Standard, Hpl ) 115 Mccb 100 Amp, 4 Pole, Ics= 100% Icu ( Havells, Standard, L&T ) 116 Mccb 200 Amp, 4 Pole, Ics= 100% Icu ( Havells, Standard, L&T ) 117 Rubber Mat 1Mtr X2mtr= 12Mm Thick 118 Spacer Suitable For Acsr Zebra Conductor With Conductor Spacing Of 300Mm Make Zi Or Equivalent 119 100Amp Four Pole Change Over Switch Of Hpl Make 120 1.1Kv Voltage Grade 20Mm2 Single Core Copper Conductor Pvc Insulated Industrial Cable Conforming To Is: 1554-1998 121 1.1Kv Voltage Grade 2.5Mm2 2 Core Copper Conductor, Pvc Insulated Control Cable Conforming To Is: 1554-1998 122 1.1Kv Voltage Grade 2.5Mm2 4 Core Copper Conductor, Pvc Insulated Control Cable Conforming To Is: 1554-1998 123 1.1Kv Voltage Grade 2.5Mm2 6 Core Copper Conductor, Pvc Insulated Control Cable Conforming To Is: 1554-1998 124 1.1Kv Voltage Grade 2.5Mm2 8 Core Copper Conductor, Pvc Insulated Control Cable Conforming To Is: 1554-1998 125 1.1Kv Voltage Grade 2.5Mm2 12 Core Copper Conductor, Pvc Insulated Control Cable Conforming To Is: 1554-1998 126 1.1Kv Voltage Grade 2.5Mm2 16 Core Copper Conductor, Pvc Insulated Control Cable Conforming To Is: 1554-1998 127 1.1Kv Voltage Grade 2.5Mm2 20 Core Copper Conductor, Pvc Insulated Control Cable Conforming To Is: 1554-1998 128 Cable Ferrules A To Z And 0 To 9 129 Red Oxide Enamel Paint ( Asian, Nerolac / Berger ) 130 Al. Paint ( Asian, Nerolac / Berger ) 131 Smoke Grey Enamel Paint 132 Polypropylene Rope ½’, ¾’& 1’ / Garware Make 133 Manila Rope ¾’ & 1’ Dia 134 Steel Wire Rope Sling 16Mm Dia Isi Make 2 Mtr. Long Heavy Duty As Per Sample 135 Steel Wire Rope Sling 16Mm Dia Isi Make 5 Mtr. Long Heavy Duty As Per Sample 136 Steel Wire Rope Sling 16Mm Dia Isi Make 10 Mtr. Long Heavy Duty As Per Sample 137 Terminal Testing Block / Kit Required For The Installation Of Tvm. 138 132Kv Voltage Grade Portable Earthing / Discharge Equipment With Statie Phasing Rod & Hotline Indicators With Following Specifications Nmake Monrach Nmodel Safety First Nstandard Iec-1235 For Dielectric Strength N Iec- 1230 For Mech. And Short N Ckt Strength Nlength Of Segmented 3.4Mtr. Nfiber Glass Pole Ninternal Dia Id 33Mm Nouter Dia Od 40Mm Nearthing Cable 102Mm Single Core Pvc Insulated N Copper Conductor Cable N Nlength Of Earthing Cable 10Mtr. Nhardware Accessories Clamp Holder, Line And Clamp, ” N Earth End “U Clamp Etc N 139 33Lv La Station Type Make Oblam Etc. 140 Automatic Voltage Stabilizer 6Kva Single Phase, 90 Volt To 280 Volt Suitable For Air Conditioner Of 2 Tom Capacity 141 Copper Strip Bus Bar Of Ec Grade 30X6mm 142 Disc Insulator 70Kn B&S Type, Anti Fog ( Bhel, Rashtriya / Iec, Jayashree Make ) 143 Disc Insulator 70Kn B&S Type, Without Anti Fog ( Hc, Top Line, Rr Make ) 144 Disc Insulator 90Kn B&S Type, Anti Fog ( Bhel, Rashtriya / Iec, Jayashree Make ) 145 Disc Insulator 90Kn B&S Type, Without Anti Fog ( Hc, Top Line, Rr Make ) 146 Disc Insulator 120Kn B&S Type, Anti Fog ( Bhel, Rashtriya / Iec, Jayashree Make ) 147 Disc Insulator 120Kn B&S Type, Without Anti Fog ( Hc, Top Line, Rr Make 148 T&P Items 149 Turn Table For Acsr Panther / Zebra Conductor With Capacity Of 3Mt Made Of Mild Steel With Double Ball Bearing Nlikely Makes Pee, Zi, Honeywell, Burma Etc N 150 Four Sheeve Pulley Steel Frame Forged Swivel Hook As Per Is 8610 Pulley Material And Ball Bearing Of Gun Metal Bush With Open Type Pulley Isi Mark Suitable For 12Mm Steel Rope 151 Bolted Type Come Along Clamp Suitable For Aaac Panther 37 / 3.15Mm With Al Alloy Clamp And Groove Inside For Conductor Gripping. Hook And Eye Bolt Of Galvanized Carbon Steel, Locking Bolts Made Of High Tensile Steel Is: 2121 Tension Limits = 2495Kg Nlikely Makes Pee, Zi, Honeywell, Burma Etc N 152 Bolted Type Come Along Clamp Suitable For Aaac Panther 37 / 2.88Mm With Al Alloy Clamp And Groove Inside For Conductor Gripping. Hook And Eye Bolt Of Galvanized Carbon Steel, Locking Bolts Made Of High Tensile Steel Is: 2121 Tension Limits = 2495Kg Nlikely Makes Pee, Zi, Honeywell, Burma Etc N 153 Bolted Type Comealong Clamp For Earth Wire Size 7 / 3.66Mm Groove According To Size Of Earth Wire Bolts Of High Tensile Steel Nlikely Makes Pee, Zi, Honeywell, Burma Etc N 154 Snatch Galvanized Pulley Size 6” Dia Pulley On Ball Bearing / Gun Metal Bush With Swivel Hook Open Type With Side Locking Suitable For Use In Trans Line Stringing Nlikely Makes Pee, Zi, Honeywell, Burma Etc N 155 Al Alloy Snatch Roller Pulley Size 8”Dia Pulley On Ball Bearing / Gun Metal Bush With Swivel Hook Open Type With Side Locking Suitable For Use In Trans Line Stringing Nlikely Makes Pee, Zi, Honeywell, Burma Etc N 156 Megger 5Kv Nlikely Make Motwani, Waco, Riken Etc N 157 Avo Meter Nlikely Make Motwani, Waco, Riken Etc N 158 Hook On Meter Nlikely Make Motwani, Waco, Riken Etc N 159 Insulating Hand Gloves 33Kv Make Crystal Etc Tested For 33Kv Level 160 12V Rechargeable Search Light With Inbuilt Charger Complete With Dimmer & Flasher Of Reputed Make Such As Vks Etc 161 Rain Coat Of Duck Back Make Etc 162 Gum Boot Of Duck Back Make Etc 163 Dangari 164 Ring Spanner Of All Sizes Taparia, Jahallni, Dwellet Etc 165 Petrolemjelly 166 Distilled Water 167 Fiber Glass Sheet 168 Screw Gaze Digital 169 Veriner Clipper Digital 170 Led Flood Light 50Watt 171 Led Flood Light 30Watt 172 Led Flood Light 40Watt 173 132Kv La Station Type 174 10 / A / 220V / Ac / Dc Multi Colour Led Type Indicators 175 Al. Alloy As Per Is: 617 Of 1975 Pg Clamps 3 Bolt Type Conforming To Is: 5561-1970 ( Amended Upto Date ) And Those Stipulated In Section-Iii Of This Tender Document Suitable For Acsr Moos Having Bolts Hot Dip Galvanized Nuts And Washers Electro Galvanized And Current Carrying Capacity Equivalent To Ampacity Of Zebra Conductor. Likely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc / As Per Departmental Sample Provided. 176 Al. Alloy As Per Is: 617 Of 1975 T Clamps 3 Bolt Type Conforming To Is: 5561-1970 ( Amended Upto Date ) And Those Stipulated In Section-Iii Of This Tender Document Suitable For Acsr Moos Having Bolts Hot Dip Galvanized Nuts And Washers Electro Galvanized And Current Carrying Capacity Equivalent To Ampacity Of Zebra Conductor. Likely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc / As Per Departmental Sample Provided. 177 Al. Alloy As Per Is: 617 Of 1975 Isolator Clamps 3 Bolt Type Conforming To Is: 5561-1970 ( Amended Upto Date ) And Those Stipulated In Section-Iii Of This Tender Document Suitable For Acsr Moos Having Bolts Hot Dip Galvanized Nuts And Washers Electro Galvanized And Current Carrying Capacity Equivalent To Ampacity Of Zebra Conductor. Likely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc / As Per Departmental Sample Provided. 178 Al. Alloy As Per Is: 617 Of 1975 Breaker Clamps 3 Bolt Type Conforming To Is: 5561-1970 ( Amended Upto Date ) And Those Stipulated In Section-Iii Of This Tender Document Suitable For Acsr Moos Having Bolts Hot Dip Galvanized Nuts And Washers Electro Galvanized And Current Carrying Capacity Equivalent To Ampacity Of Zebra Conductor. Likely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc / As Per Departmental Sample Provided. 179 Al. Alloy As Per Is: 617 Of 1975, Bi-Mettalic Ct Pad Clamp ( Universal Take Off ) Conforming To Is: 5561-1970 ( Ammended Upto Date ) And Those Stipulated In Section-Iii Of This Tender Document Suitable For Twin Acsr Moos Conductor With Conductor Spacing 300Mm And Ct Terminal Spacing Of 140Mm Having Bolts Hot Dip Galvanized Nuts And Washers Electro Galvanized And Current Carrying Capacity Equivalent To Ampacity Of Twin Zebra Conductor With Pad Terminals Suitable For 132Kv / 33Kv Cts Of Ae Mumbai, Sct Gazaibad, Bhel, Vidhyut Control Andhra, Mehru Bhiwadi / Laxmi Engg Bhopal Vidhyut Control Andhra, Jyoti Etc Nlikely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc / As Per Departmental Sample Provided 180 Al. Alloy As Per Is: 617 Of 1975, Bi-Mettalic Isolator Pad Clamp ( Universal Take Off ) Conforming To Is: 5561-1970 ( Ammended Upto Date ) And Those Stipulated In Section-Iii Of This Tender Document Suitable For Twin Acsr Moos Conductor With Conductor Spacing 300Mm And Ct Terminal Spacing Of 140Mm Having Bolts Hot Dip Galvanized Nuts And Washers Electro Galvanized And Current Carrying Capacity Equivalent To Ampacity Of Twin Zebra Conductor With Pad Terminals Suitable For 132Kv / 33Kv Cts Of Ae Mumbai, Sct Gazaibad, Bhel, Vidhyut Control Andhra, Mehru Bhiwadi / Laxmi Engg Bhopal Vidhyut Control Andhra, Jyoti Etc Nlikely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc / As Per Departmental Sample Provided 181 Al. Alloy As Per Is: 617 Of 1975 T Clamps 3 Bolt Type Conforming To Is: 5561-1970 ( Amended Upto Date ) And Those Stipulated In Section-Iii Of This Tender Document Suitable For Acsr Moos Having Bolts Hot Dip Galvanized Nuts And Washers Electro Galvanized And Current Carrying Capacity Equivalent To Ampacity Of Zebra Conductor. Likely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc / As Per Departmental Sample Provided. 182 Al. Alloy As Per Is: 617 Of 1975 Isolator Clamps 3 Bolt Type Conforming To Is: 5561-1970 ( Amended Upto Date ) And Those Stipulated In Section-Iii Of This Tender Document Suitable For Acsr Moos Having Bolts Hot Dip Galvanized Nuts And Washers Electro Galvanized And Current Carrying Capacity Equivalent To Ampacity Of Zebra Conductor. Likely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc / As Per Departmental Sample Provided. 183 Al. Alloy As Per Is: 617 Of 1975 Breaker Clamps 3 Bolt Type Conforming To Is: 5561-1970 ( Amended Upto Date ) And Those Stipulated In Section-Iii Of This Tender Document Suitable For Acsr Moos Having Bolts Hot Dip Galvanized Nuts And Washers Electro Galvanized And Current Carrying Capacity Equivalent To Ampacity Of Zebra Conductor. Likely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc / As Per Departmental Sample Provided. 184 3Phase High Speed Industrial Exhaust / Cooling Fan For Power Transformer With Following Specifications Nmake Crompton Greaves Voltage 415V Nfrequency 50Hz Nsweep 600Mm ( 24Inch ) Speed 960 Rpm 185 3Phase High Speed Industrial Exhaust / Cooling Fan For Power Transformer With Following Specifications Nmake Crompton Greaves Voltage 415V Nfrequency 50Hz Nsweep 450Mm ( 18 Inch ) Speed 1400 Rpm 186 Pvc Insulated Single Core Cable 95Mm Isi Make Unarmoured 187 Thinner 188 Dewatering Pump Set Mono Block 1 Phase 2Hp Capacity 189 Transformer Oil Testing Bottle For Dga Testing Of Oil N N 190 1.1Kv Voltage Grade Al Conductor Pvc Insulated Cable Single Core 120Mmsq Isi Make Unarmoured 191 Safety Helmat Isi Make 192 Digital Insulation Resistance Tester ( Magger ) 193 Refilling Of Dcp Fire Extinguisher Of 50Kg Capacity 194 Refilling Of Dcp Fire Extinguisher Of 25Kg Capacity 195 Refilling Of Dcp Fire Extinguisher Of 10Kg Capacity 196 Refilling Of Co2 Type Fire Extinguisher Of 22.5Kg Capacity 197 Refilling Of Co2 Type Fire Extinguisher Of 22.5Kg Capacity 198 House Pipe Dcp Type Fire Extinguisher Of 10Kg Capacity 199 House Pipe Dcp Type Fire Extinguisher Of 25Kg Capacity 200 House Pipe Dcp Type Fire Extinguisher Of 50Kg Capacity 201 House Pipe Of Co2 Type Fire Extinguisher Of 22.5Kg Capacity 202 Al. Alloy As Per Is: 617 Of 1975, Bi-Mettalic Ct Clamp ( Universal Take Off ) Conforming To Is: 5561-1970 ( Ammended Upto Date ) And Those Stipulated In Section-Iii Of This Tender Document Suitable For Twin Acsr Moose Conductor Having Bolts Hot Dip Galvanized Nuts And Washers Electro Galvanized And Current Carrying Capacity Equivalent To Ampacity Of Zebra Conductor With Ct Terminals Suitable For 132Kv / 33Kv Cts Of Makes / Ae Mumbai, Sct Gaziabad, Bhel, Vidhyut Control System Andhra, Mehru Bhiwadi / Laxshmi Engg Bhopal, Jyoti Etc Nlikely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc / As Per Departmental Sample Provided 203 Al. Alloy As Per Is: 617 Of 1975, Bi-Mettalic Breaker Pad Clamp ( Universal Take Off ) Conforming To Is: 5561-1970 ( Ammended Upto Date ) And Those Stipulated In Section-Iii Of This Tender Document Suitable For Twin Acsr Moose Conductor Having Bolts Hot Dip Galvanized Nuts And Washers Electro Galvanized And Current Carrying Capacity Equivalent To Ampacity Of Zebra Conductor With Pad Terminals Suitable For 132Kv / 33Kv Breakers Of Sf 6 Type-Abb, Cgl, Siemens, Bhel / Vcb Type- S&S, Gec Alsthom, Bhel, Abb, Siemens, Megawin Etc. Nlikely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc / As Per Departmental Sample Provided N 204 P.I Clamp For Acsr Moose Conductor 205 Single Suspension Hardware Fitting For Acsr Moose Conductor Conforming To Is 2486 ( Part-I ) Ammended Upto Date And The Specification Stipulated In Sec. Iii Of This Tender Document Having Suspension Clamp Of Al Alloy Grade-A6 ( Is: 617-1975 ) , Ferrous Parts Hot Dip Galvanized ( Is: 2633 1986 ) Suitable For 16Mm B&S 70Kn Disc Insulators., Ultimate Tensile Strength Of ( H / W ) 7000Kg Nlikely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc / As Per Departmental Sample Provided Na. Station Type Nb. Line Type 206 Single Tension Hardware Fitting For Acsr Moose Conductor Conforming To Is 2486 ( Part-I ) Ammended Upto Date ) And The Specification Stipulated In Sec. Iii Of This Tender Document Having Tension Clamp Of Al Alloy Grade-A6 ( Is: 617-1975 ) , Ferrous Parts Hot Dip Galvanized ( Is: 2633 1986 ) Suitable For 20Mm B&S 120Kn Disc Insulators., Nuts Of Hardware = 900Kg Nuts / Slip Strength Of Clamp = 95% Of Uts Of Conductor N = 8550 Kg Nlikely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc / As Per Departmental Sample Provided Na. Station Type Nb. Line Type N 207 Double Suspension Hardware Fitting For Moose Conductor Conforming To Is 2486 ( Part-I ) Ammended Upto Date ) And The Specification Stipulated In Sec. Iii Of This Tender Document Having Suspension Clamp Of Al Alloy Grade-A6 ( Is: 617-1975 ) , Ferrous Parts Hot Dip Galvanized ( Is: 2633 1986 ) Suitable For 16Mm B&S 70Kn Disc Insulators., Nuts Of Hardware =7000Kg Nlikely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc / As Per Departmental Sample Provided Na. Station Type Nb. Line Type 208 Single Tension Fitting For Acsr Twin Moose Conductor Conforming To Is 2486 ( Part-I ) Ammended Upto Date And The Specification Stipulated In Sec. Iii Of This Tender Document Having Tension Clamp Of Al Alloy Grade-A6 ( Is: 617-1975 ) , Ferrous Parts Hot Dip Galvanized ( Is: 2633 1986 ) Suitable For 20Mm B&S 120Kn Disc Insulators., Nuts Of Hardware = 9000Kg Nuts / Slip Strength Of Clamp = 95% Uts Of Conductor N = 8550 Kg Nlikely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc / As Per Departmental Sample Provided Na. Station Type Nb. Line Type 209 Single Suspension Fitting For Acsr Twin Moose Conductor Conforming To Is 2486 ( Part-I ) Ammended Upto Date And The Specification Stipulated In Sec. Iii Of This Tender Document Having Tension Clamp Of Al Alloy Grade-A6 ( Is: 617-1975 ) , Ferrous Parts Hot Dip Galvanized ( Is: 2633 1986 ) Suitable For 20Mm B&S 120Kn Disc Insulators., Nuts Of Hardware = 9000Kg Nuts / Slip Strength Of Clamp = 95% Uts Of Conductor N = 8550 Kg Nlikely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc / As Per Departmental Sample Provided Na. Station Type Nb. Line Type 210 Spacer Suitable For Acsr Mosse Conductor With Conductor Spacing Of 300Mm Make Zi Or Equivalent 211 Spacer Suitable For Acsr Mosse Conductor With Conductor Spacing Of 150 Mm Make Zi Or Equivalent 212 Single Core 630Sq Mm 33Kv Heat Shrinkable Cable Kit Outdoor Type Nlikely Make Raychem Make N 213 Single Core 630Sq Mm 33Kv Heat Shrinkable Cable Kit Indoor Type Likely Make Raychem Make 214 3½ Core 50Mmsq Al. Conductor Pvc Insulated Cable Of 1.1Kv Voltage Grad 215 3½ Core 95Mmsq Al. Conductor Pvc Insulated Cable Of 1.1Kv Voltage Grad 216 Crimping Tool Hydraulic 300 / 630Mmsq Xlpe Cable 217 Al Cable 2 Core 16Mmsq 218 Al Cable 2 Core 10Mmsq 219 Al Cable 2 Core 25Mmsq 220 Mccb 63Amp Tpn 221 Al Strip 75X12mmsq 222 Copper Strip 75X12mmsq 223 P.G Clamp Moose To Zebra 224 T Clamp Moose To Zebra 225 Aux. Relay 110Vdc 226 33Kv Cts 1200-600-300 / 1Amp.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 5
Jammu And Kashmir View Result →
23.
Defence #8369068 AOC
Tender For Provision Of Klp At Samba; 1 Schedule A Part-I.Constructions of Administrative Building (G+1) complete all as specified and as shown in drgs. 2 Construction of Car, Bicycle and Scooter shed for Adm Office complete all as specified and as shown in drgs. 3 Construction of Single living Accn for officers (S/S) complete all as specified and as shown on drgs. 4 Construction of Car Garages for Offrs Mess (04 Nos) + Single Offrs (02) and Servant Qtrs passing and open garage with apron for Cars complete all as specified and as shown on drgs. 5 Construction of Offrs Mess (11 to 18) (S/S) complete all as specified and as shown on drgs. 6 Construction of JCO Mess Club (41 to 60) and single living accn (15 Nos) (G+2) & parking complete all as specified and as shown on drgs. 7 Construction of Single Living Accn for 79 ORs and 26 HAVs (G+3) along with cook house and dinning hall complete all as specified and shown on drgs. 8 Construction of single living accn for 60 ORs and 12 HAVs (G+3) along with cook house and dinning hall complete all as specified and as shown on drgs. 9 Construction of single living accn for 53 ORs and 16 HAVs (G+3) along with cook house and dinning hall complete all as specified and shown on drgs. 10 Construction of scooter shed for single living accn ORs/ HAVs (For 60 scooters) complete all as specified and as shown on drgs. 11 Construction of scooter shed for single living accn ORs/ HAVs (For 100 scooters) complete all as specified and as shown on drgs. 12 Construction of Guard house, SAA store, Armour Shop and Armouries (S/S) complete all as specified and as shown on drgs. 13 Construction of Storage Accn (S/S) complete all as specified and as shown on drgs. 14 Construction of Instruction room & Instruction store/shed (G+1) complete all as specified and as shown on drgs. 15 Construction of OR’s Institute (S/S) complete all as specified and as shown on drgs. 16 Construction of Station Store (S/S) complete all as specified and as shown on drgs. 17 Construction of Drying and Ironing room & mechanical laundary (S/S) complete all as specified and as shown on drgs. 18 Construction of Religious Institute hall complete all as specified and as shown on drgs. 19 Construction of URC + Family Welfare Centre (G+1) complete all as specified and as shown on drgs. 20 Construction of Guard Room complete all as specified and as shown on drgs. 21 Construction of Elevated Sentry Post with toilet complete all as specified and as shown on drgs. 22 Construction of Incinerator complete all as specified and as shown on drgs. 23 Construction of Fire point complete all as specified and as shown on drgs. 24 Construction of Alarm post 04 (Nos) and Flag mast complete all as specified and as shown on drgs. 25 Construction of Garbage and Refuse Bin complete all as specified and shown on drgs. 26 Lumpsum price worked out by the contractor for Earth work, Site Clearance and Site development works as listed in Schedule A Part-II. 27 Lumpsum price worked out by the contractor for Internal Water Supply works as listed in Schedule A Part-III. 28 Lumpsum price worked out by the contractor for Internal Electrification works as listed in Schedule A Part-IV. 29 Lumpsum price worked out by the contractor for Protective works as listed in Schedule A Part-V. 30 Lumpsum price worked out by the contractor for Road, Path and culvert worksas listed in Schedule A Part-VI. 31 Lumpsum price worked out by the contractor for Sewage Disposal works as listed in Schedule A Part-VII. 32 Lumpsum price worked out by the contractor for PCC Hardstanding works as listed in Schedule A Part-VIII. 33 Lumpsum price worked out by the contractor for Area Drainage works as listed in Schedule A Part-IX. 34 Lumpsum price worked out by the contractor for External Water Supply works as listed in Schedule A Part-X. 35 Lumpsum price worked out by the contractor for External Electrification works as listed in Schedule A Part-XI. 36 Lumpsum price worked out by the contractor for Hot water Supply works as listed in Schedule A Part-XII. 37 Lumpsum price worked out by the contractor for Security Fencing and Steel gate works as listed in Schedule A Part-XIII. 38 Lumpsum price worked out by the contractor for Demolition and Dismantling works as listed in Schedule A Part-XIV. 39 EARTH WORK, SITE CLEARANCE & SITE DEVELOPMENT WORKSEarthwork in excavation in trenches or drains in any type of soil by mechanical means (hydraulic excavator)/(not exceeding 1.5m in width and 10 Sqm on plan), exceeding 1.5m upto 3.00m in depth, including dressing of sides and ramming of bottoms, left upto 1.5m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50metre complete all as specified and directed. 40 Earthwork in excavation in trenches or drains in any type of soil by mechanical means (hydraulic excavator)/(not exceeding 1.5m in width and 10 Sqm on plan), exceeding 3.00m upto 4.50m in depth, including dressing of sides and ramming of bottoms, left upto 1.5m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50metre complete all as specified and directed. 41 Earthwork in rough excavation in any type of soil by mechanical means (hydraulic excavator) not exceeding 1.5m deep and getting out and disposal of excavated earth lead upto 50m and lift upto 1.5m complete all as specified and directed by Engineer-in-Charge. 42 Internal Water SupplyGalvanized iron steel water tubing, 15mm bore, medium grade, with all fittings (ISI Marked), fixed complete to walls, ceiling and laid in floors concealed type including cutting chases for concealed water tubing and making good in CM (1:3) complete all as specified and as directed by Engineer-in-Charge. 43 Galvanized iron steel water tubing, 20mm bore, medium grade, with all fittings (ISI Marked), fixed complete to wall, ceiling and laid in floors concealed type including cutting chases for concealed water tubing and making good in CM (1:3) complete all as specified and as directed by Engineer-in-Charge. 44 Internal Electrification Works LED Tube Light 20 Watt luminaire basic all purpose surface and wall mounted LED batten with polycarbonate housing and integrated electronic driver complete including connecting up with three core flexible copper conductor cable of suitable size from ceiling rose to LED fitting connector and necessary mounting clamp on two sets complete all as specified & directed by Engineer-in-Charge. 45 Round shape 06 watt 220 volts AC recessed/ ceiling mounted type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified & directed by Engineer-in-Charge. 46 Round shape 15 watt 220 volts AC recessed/ ceiling mounted type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified & directed by Engineer-in-Charge. 47 Round shape 12 watt 220 volts AC recessed/ ceiling mounted type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified & directed by Engineer-in-Charge. 48 LED Luminiare 600mm x 600mm, 36 Watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders and LED lamps suitable with roof ceiling connecting up with driver 3 core flexible copper conductor cases of suitable size complete all as specified & directed by Engineer-in-Charge. 49 LED street light fitting 20 watt, 230 volts, AC outdoor type with high pressure die cast aluminium housing and heat resistance complete with driver, lamp bracket with impact corrosion resistant including thermal management multiple optics complete with IP 65/66 protection complete including suitable size GI bracket with medium grade pipe required nut, bolt, washers to fixed on existing wall complete all as specified & directed by Engineer-in-Charge. 50 Single pole and neutral enclosure with a two pin and earth plug and socket complete with one double pole phase and neutral MCB 20 Amps complete for AC point complete all as specified & directed by Engineer-in-Charge. 51 Ceiling fans complete with blades, down rods, including electronic regulator and accessories, 230 V, 1200mm steep, Min air delivery, 210 CFM with service value 6.00 BEE point five star rated with brushless direct current mortor (BLDC) complete all as specified & directed by Engineer-in-Charge. 52 Exhaust fan, steel body AC Single phase, 230 volt of size 300mm sweep with blades and frame and louvers complete all as specified & directed by Engineer-in-Charge.Note: The contractor should make necessary hole for fixing exhaust fan and fix the exhaust fan with suitable size of fastener and bolts in wall deemed to be included in the quoted rate. 53 MCCB 3 pole, 440 volt, 25-100 Amps rating capacity of breaking capacity 16 kA, fixed type complete all as specified and directed by Engineer-in-Charge. 54 MCCB 3 pole, 440 volt, 160 Amps rating capacity of breaking capacity 16 kA, fixed type complete all as specified and directed by Engr-in-Charge. 55 Sheet metal enclosures distribution boards, double door VTPN, 415 volts 6 way suitable for fixing MCCB as incomer and MCBs as outgoing (One incoming three phase & twelve outgoings single phase) for MCCB & MCBs comprising three phase four wire copper strip bus bar of appropriate capacity complete all as specified and directed.Notes:(i) The DB shall be VTPN series.(ii) The DB shall be flush fixed and making disturbed surface matching with existing specifications shall be part of work no extra cost.(iii) Connection of the MCCBs and MCBs with cable shall be made through appropriate size pin/ bottle type copper thimble properly crimped.(iv) All the vacant holes of the DB shall be provided with blank plates of appropriate size.(v) Double continuous earth wire shall be provided for each three phase DB from earthing mains dolly.(vi) MCCB and MCB rate considered in separate item of schedule. 56 Sheet metal enclosures distribution boards, double door VTPN, 415 volts 4 way suitable for fixing MCCB as incomer and MCBs as outgoing (One incoming three phase & twelve outgoings single phase) for MCCB & MCBs comprising three phase four wire copper strip bus bar of appropriate capacity complete all as specified and directed.Notes:(i) The DB shall be VTPN series.(ii) The DB shall be flush fixed and making disturbed surface matching with existing specifications shall be part of work no extra cost.(iii) Connection of the MCCBs and MCBs with cable shall be made through appropriate size pin/ bottle type copper thimble properly crimped.(iv) All the vacant holes of the DB shall be provided with blank plates of appropriate size.(v) Double continuous earth wire shall be provided for each three phase DB from earthing mains dolly.(vi) MCCB and MCB rate considered in separate item of schedule. 57 Earthing with galvanized steel earth plate electrode 600 x 600 x 6.0mm thick buried directly in ground pit not less than 2.25mtr deep below ground level with top edge of plate not less than 1.5 mtr below normal ground level connected to 4.00mm dia GI wire & PVC insulated solid copper conductor of size 4mm by means of nuts and GI washers including PCC pit in PCC 1:2:4 type B-1 RCC cover, 20mm dia (MG) GI watering pipe with funeel wire mesh and protection pipe of GI of 15mm dia up to 7.5mtr length including charcoal black cotton soil as required at site to achieve the earthing result and common salt, excavation earth work etc in any type of strata complete all as shown in electrical plate No 3 of MES SSR Part-I as specified. GI wire & 4mm dia solid conductor PVC insulated for continuity earth wire from test point to main distribution board and all as specified and as directed. Note :- Rate for achieving required depth by compressor machine if required is deemed to be included on the quoted unit rate. 58 Road, Path & CulvertsReflective type cat eye having colour red/yellow to a side, casted aluminium allow of size 1100x100x20mm with built in steam of suitable length for fixing with protected in side as approved by complete all as specified and directed Engineer-in-Charge, Cat Part no OS-786. 59 Stainless steel round delineator having reflector type red/ yellow colour in plastic body protected in side poly carbonated sheet, protected with powder coated wire mesh cage system mounted as approved by complete all as specified and directed Engineer-in-Charge, cat part no. OS-802. 60 Information board with ACP sheet retro reflective writing one side size 600x900 mm. Made around of reflective intensive tape dully fixed on angle iron frame 40x4x4 mm frame with aluminium sheet both side 2mm thick as requiredwith PCC 1:4:8 for post and PCC directed by complete all as specified and directed Engineer-in-Charge. 61 Sewage DisposalDWCPE (SN8) 180 (OD)/ 163(D)mm diameterpipes integral socket and necessary fittings, laid in trenches including jointed and overlapping of pipes complete all as specified and as directed by Engineer-in-Charge. 62 DWCPE (SN8) 200 (OD)/ 175(D)mm diameterpipes integral socket and necessary fittings, laid in trenches including jointed and overlapping of pipes complete all as specified and as directed by Engineer-in-Charge. 63 LLDPE septic tank made of polyethylene, single moulded, and conventional type. The unique size and three chamber design of any make from syntax/ united/ supreme. It should have atleast two manholes provided for convenience and salt resistance and made by non degradable plastic capacity for 10 users, thickness min 10mm, size of manholes 550mm dia. Dia of inlet and outlet pipe should be 110mm and dia of vent pipe is 50mmcomplete all as specified and as directed by Engineer-in-Charge. 64 RCC septic tank for 50 users with effective depth of 1.5 metre and overall depth of 3metre, complete all as specified and shown on drgs and as directed by Engineer-in-Charge. 65 RCC septic tank for 100 users with effective depth of 1.5 metre and overall depth of 3metre, complete all as specified and shown on drgs and as directed by Engineer-in-Charge. 66 RCC septic tank for 150 users with effective depth of 1.5 metre and overall depth of 3metre, complete all as specified and shown on drgs and as directed by Engineer-in-Charge. 67 RCC septic tank for 200 users with effective depth of 1.5 metre and overall depth of 3metre, complete all as specified and shown on drgs and as directed by Engineer-in-Charge. 68 Construction of soakage well, (brick construction) size 1.8mtr dia 3.0m deep, below inlet pipe level (depth from inlet pipe to ground level to 45cm) complete all as specified and shown on drgs and as directed by Engineer-in-Charge. 69 Construction of soakage well, (brick construction) size 3.0mtr dia 4.5m deep, below inlet pipe level (depth from inlet pipe to ground level to 45cm) complete all as specified and shown on drgs and as directed by Engineer-in-Charge. 70 Construction of soakage well, (brick construction) size 3.0mtr dia 6.0m deep, below inlet pipe level (depth from inlet pipe to ground level to 45cm) complete all as specified and shown on drgs and as directed by Engineer-in-Charge. 71 Construction of soakage well, (brick construction) size 3.6mtr dia 6.0m deep, below inlet pipe level (depth from inlet pipe to ground level to 45cm) complete all as specified and shown on drgs and as directed by Engineer-in-Charge. 72 Construction of soakage well, (brick construction) size 2.4mtr dia 4.5m deep, below inlet pipe level (depth from inlet pipe to ground level to 45cm) complete all as specified and shown on drgs and as directed by Engineer-in-Charge. 73 CHIMNEYSupply and fixelectric stainless steel commercial chimney of capacity 1250CFM/hr of size 6 feet hood and size 2 feet length (30 inch in length each with BLDC motor of suitable size ) with LED light , purfreted filter complete along with fixing with help of angle bold complete all as specified by manufarcturer and making hole for flexible exhaust pipe through cutting of wall and making outlet at outside the kitchen area complete all as specified. 74 Earthing complete with galvanized steel earth plate electrode 600x600x6mm thick buried in ground vertical to a depth not less than 2.25 mtrs deep below ground level with top edge of plate not less than 1.5mtr below normal ground level connected to GI galvanized iron strip of size 32×6mm and 40mm dia bore light grade GI protection pipe for earth strip and GI watering pipe 20 mm dia medium grade from the top edge of earth plate fixed with deep cut on one end of pipe and fix from earth plate up to one feet above ground level of other end and plugged watering pipe at top with MS cap and grouted in PCC 1:2:4 of size 30 X 30 X 30 CM etc and 15 CM alternate layer of charcoal and salt around all sides of earth plate all as shown in electric plate no 3 of SSR part I of 2009 complete all as specified and directed. (Transformer -04 Nos + VCB-02 Nos + 7 NOs Panel -14 Nos + Compacted Sub-station-02 Nos) 75 Supply, laying, jointing and testing LT cable 1100 volts grade of cross sectional area400 sqmm 3.5 core as per IS-7098 (Part-I) 1988, XLPE insulated aluminium conductor heavy duty served with an inner sheathing PVC tape, galvanized steel strip or wire armoured with an overall PVC sheathing laid in trenches, fixed along the poles or passed through GI pipe using clamps wherever required , laid under floors, road etc fixed concealed in walls encased in GI pipe connecting with suitable size of lugs and cable glands etc, each cable termination is to be made with suitable size of cable glands and aluminium thimbles (for junction boxes, security lights, LT panels etc) for incoming and outgoing cables complete all as specified and as directed.Note:- (i) MS clamps with nuts, bolts washer etc required for fixing on wall rate deemed to be included on the quoted rate. (ii)Cable path indicators shall be provided at distance of every 100 metre s and at cable joints and turning of all cables except for 2 core cables size and voltage written on it. The CI path indicator shall be fixed on MS angle iron. The cable path indicators shall be erected at the time of refilling the trenches and the cable path indicator shall be painted as under. -(i) For LT cables - “BLUE”. (iii) Earth work like excavation, Returning re filling, removal, sand cushioning, cable covers, GI pipe measured and paid separately under relevant item of schedule. 76 All as per Item No 75 above but size of cable 300 Sqmm 3.5 core complete all as specified and as directed by Engineer-in-Charge. 77 All as per Item No 75 above but size of cable 240 Sqmm 3.5 core complete all as specified and as directed by Engineer-in-Charge. 78 All as per Item No 75 above but size of cable 150 Sqmm 3.5 core complete all as specified and as directed by Engineer-in-Charge. 79 All as per Item No 75 above but size of cable 70 Sqmm 3.5 core complete all as specified and as directed by Engineer-in-Charge. 80 All as per Item No 75 above but size of cable 50 Sqmm 3.5 core complete all as specified and as directed by Engineer-in-Charge. 81 All as per Item No 75 above but size of cable 25 Sqmm 4.0 core complete all as specified and as directed by Engineer-in-Charge. 82 All as per Item No 75 above but size of cable 16 Sqmm 4.0 core complete all as specified and as directed by Engineer-in-Charge. 83 All as per Item No 75 above but size of cable 16 Sqmm 2.0 core complete all as specified and as directed by Engineer-in-Charge. 84 All as per Item No 75 above but size of cable 10 Sqmm 2.0 core complete all as specified and as directed by Engineer-in-Charge. 85 All as per Item No 75 above but size of cable 10 Sqmm 4.0 core complete all as specified and as directed by Engineer-in-Charge. 86 Structural steel work as the cross arms, bracing supports, clamps, back plate fabricated from structural steel sections including nut bolts, washers, welding, bending hot or cold drilling holes for both in any shape or size as indicated or directed by Engineer-In-Charge and inclusive of one primer coat one under coat and one finishing coat of synthetic enamelled paint including preparation of surfaces. 87 Supply, install, testing and commissioning of 11 KV, 350 MVA, 630 A rating, 18.4 KA (Short time current rating), 1 Way, indoor VCB with EnclosureMotorized type as per Specification with 1 incoming and 1 outgoing VCB complete all as specified and directed by Engineer-in-Charge.Location: Sub station No 02 GE Samba office inside campus1. Each Incomer feeder with Switch consists of: (a) Motorized 630 A, 350 MVA VCB enclosure with built in earth switch with full making capacity-01 Nos(b) Mechanical position indicator. Switch ON/ OFF/ Earthed-01 No(c) Live cable indication-01 No(d) Cable compartment cover interlocked with earth switch-01 No.(e) Cable termination bushing-01 Nos for 3 Core 95 Sqmm HT cable.(f) 11 KV XLPE Cable termination Kit with boot-01 Set(g) NO/NC contact for -01 Set(i)Isolator ON/OFF (ii) Earth Switch ON/OFF (iii) Fault indicator Operated.(h) Command Output for -01 Set(i) Isolator close(ii) Isolator Open(iii) FPI Reset(j) Anti Pumping Relay -01 Nos 88 (k) Digital MFM (EM646 or equvt) -01 Nos. (l) Indications: (i) ON/OFF/Trip Indication Light -01 Sets. (ii) Spring Charge Healthy indication-01 Nos. (iii) Trip Circuit Healthy Indication-01 Nos. (iv) Test / Service Postion Indicator-01 Set. (n) Breaker Control Switch-01 No.(o) L/R Switch-01 Nos(q) 3 pin Plug and socket-01 Nos. (r) Toggle switch-01 Nos. (s) Hooter-01 Nos.(t) Annuniciator 8 Watt-01 Nos. (u) 24 V DC Power Pack, 17 Ah-01 Nos. (v) Door switch-01 Nos. (w) Space Heater with thermostat-01 Nos. (x) Control MCB set comprisiong ofSPN MCBs as per relays and meters-01 Set . (y) Cable termination bushings suitable for 2 Nos 3 C x 95 Sq mm XLPE cable -01 Sets each one for one Incoming VCB(z) 11 KV Screened cable termination kit with boots-01 sets each one for one Incoming VCB 89 (a) Gas pressure indicator with auxillary contacts.(b) 1 No. Handle per RMU(c) Battery & Battery Charger3. Civil workThe platform for placing VCB as per manufacturers technical drawing and made suitable PCC ducting for laying cable and fill with reuired level fine sand on treches all as specified and directed by Engr-in-Charge. common items: (i) Battery & Battery charger.(ii)Warning board marking as HT 11 KV Danger with skull and writing with English, Hindi, local language.(iii)Before quoting rate the contractor must visit siteand to connect the new VCB to existing VCB the required size of bus bar and connected items deemed to be included on the quoted rate. The existing Incoming VCB of make CG in sub station no 2. 90 Supply, installation, testing & commissioning of package type/ unitised 11kV / 433 V Outdoor sub-station, 630 kVA made from G.I. enclosure complete as required conforming to IEC 62271-202 only and relevant IS specificationsfor the rating, Internal Arc of 21 or 18.4 KA/1 Sec. IAC AB on 1:2:4 (1 cement :2 cores and : 4 Graded stone aggrregate of 40 mm nominal size) PCC foundation of suitable size extending 500 mm all around the outdoor enclosure and 1000 mm height (above ground level) complete with suitable sizes of GI Pipes for incoming/ outgoing cables/ earthing strips etc. and consisting of following complete as required. Angle iron frame of size 40x40x5mm NS all along the corner of the foundation. RMU, LT panel switchgear and CSS enclosure shall be of same make to ensure life cycle optimization.Note : CSS shall be from OEMs only. Licensed System Integrators are not allowed to supply . 91 HT SWITCHGEAR11kV 630Amps 18.4 KA/3 secNon-Extensible Ring Main Unit Compact switchgear consisting of2 Nos. fixed manual operated Load Break Switch and1 Nos. fixed manual operatedBreaker Module in SF6 insulated stainless steel enclosure with series trip, self powered microprocessor based numerical over current and earth fault relay protection. Operating sequence of breaker must be O-0.3Sec-CO-3 Mins-CO and suitable for 10000 mechanical operations. HT RMU shall preferably have site replaceable bushings to have very less downtime in the event of bushing breakage and restoration can be done immediately without sending the RMU to OEM Works. Interconnection between HT Switchgear and primary of transformer shall be done through 1C x 3R x 95 sq.mm Aluminium XLPE cable. - 1 No.(a) Microprocessor based IDMT Relay for Circuit Breakers - Self Powered along with series trip coil.(b ) Capacitive voltage indication fixed type system with LED(c ) SF6 Gas pressure indicator.(d) Padlocking facility.(e ) Protection CT shall be minimum 60/1A ,2.5VA ,5P10. - 3 nos.(f) Operating Sequence of breakershall be O-0.3sec-CO-3MIN-CO(g) LBS module will have FPI.(h) All modules of the RMU shall be suitable for cable termination of 3C x 95 sq.mm Al XLPE Cable, incoming cable termination is included within the scope of work - 1 Set 92 TRANSFORMER630 KVA 11KV/433V DYN-11 Oil type, hermetically sealed energy efficiency level-3transformerwith corrugated wall, without conservator, type of design & Top Bushings for HT & LT with Off load tap switch of rating +5% to -5% @2.5%. Temp Rise - Oil/Winding 40/45 Deg cel. Losses (As per IS-1180 amended up to date)Max Losses @ 50% Load 1745W and Max Losses @ 100% Load 4850 W and Impedance of 4.5% (Subject to IS Tolerance (as per IS1180-2014) The transformer shall be confirming to IS: 2026 and IS: 1180(part-I). amended up to date. (Make of transformer:- As per CSS Manufacturer approved Make- One No. Winding Temperature Indicator with Alarm and trip ContactLT PANELLVS PANEL 1000 AMPS 4 pole Aluminium BUSBAR (100% FOR PHASES AND 100% FOR NEUTRAL) - CURRENT DENSITY OF Aluminium as 1 A/sq.mm. ; LT panel made up of 2 mm thick CRCA sheet 93 INCOMER FROM TRANSFORMEROne number 1000Amps 4 pole 415V MDO ACB (incoming) with moulded case construction having breaking capacity 50KA with Ics = Icu = Icw (1 sec) = 50KA with microprocessor release for over current, earth fault & short circuit protections. The ACB should be of command approved make.One number Intelligent multifunction digital meter to read V, A, KVA, KWH,THD, PF Hz, kVARh, Vah, VARh, MD, and RS 485 portetc. with 3 Nos. resin cast CTs of 400/1A class 0.5 accuracy and 5 VA burden - 1 No.One set of Phase indication LED lamps with 2 Amps. Back up MCB, breaker ON/OFF indicating light with MCB, test terminal block set, circuits as per standard practice and auxiliary contact contactors for positive electrical interlocking of breakers etc. as required.Outgoings:(a) MCCB 4 pole, 400A, 415 volt 50HZ with thermal setting 70% to 100% and rupturing capacity not less than 36 KA - 02Nos (b) MCCB 4 pole, 250 A, 415 volt 50HZ with thermal setting 70% to 100% and rupturing capacity not less than 36 KA - 01 No 94 (c) MCCB 4 pole, 200 A, 415 volt 50HZ with thermal setting 70% to 100% and rupturing capacity not less than 36 KA - 02 Nos (d) MCCB 4 pole, 160 A, 415 volt 50HZ with thermal setting 70% to 100% and rupturing capacity not less than 36 KA - 01 No (e) MCCB 4 pole, 100A, 415 volt 50HZ with thermal setting 70% to 100% and rupturing capacity not less than 16 KA - 02 Nos(f) MCB SPN 40 aMPS, - 02 Nos (for out going).One set of Phase indication LED lamps with 2 Amps. Back up MCB, breaker ON/OFF indicating light with MCB, test terminal block set, circuits as per standard practice and auxiliary contact contactors for positive electrical interlocking of breakers etc. as required.All Civil works such as PCC/RCC foundation, Plateform, Filling trench and pedestal etc as per CSS manufacturers recomandation are included in scope of work. 95 OUTDOOR ENCLOSUREOutdoor type encloser of 1.5 mm (For non load bearing members) & 2.0 mm (For load bearing members) thickness having modular construction of Galvanised Sheet Steel in suitable design for better heat dissipation and providing robust construction. The Enclosure shall have IP54 degree of protection for HT & LT switchgear compartment & IP 23 degree of protection for transformer compartment. The enclosure exterior shall be painted with epoxy based powder paint (colour RAL 7032). Each compartment will be provided with the door and pad locking arrangement. The design of the enclosure should be type tested for suitablly handling any arcing inside the compartment for providing better safety to the operator. The compartment illumination lamp with door operated switch shall be provided for each compartment. The supply of all above equipments, erection, testing and commissioning and suitable size of manufacture recommended plinth for erectoin of CSS rate included on the quoted rate. The contractor should submit the technical drawing of Compact sub station including Transformer, HT /LT breakersand foundation drawing recommended by the manufacturer for approval of this office. The rate included for the PDI test and the first fill of Transformer oil. The contractor should submit all Test report of Transforemr, LT /HT panels before made payment by department. 96 Solar two in one (semi integrated)LED street lights 36Watt with aluminium housing, weather proof IP 66>125 lm/watt efficacy, 75Wp solar module of solar PV panel poly crystalline, inbuilt 36 Ah solarbattery 12.8 V, LiFEPo4battery with BMS, dimming and charging controller of MPPT Integral charge controller of electronic efficiency>90% (Inbuilt into the street light), PIR sensor, 5500-6500 K, short circuit protection, reverse polarity protection and prevent reverse discharge battery, overcharge/deep charge protection all as specified and directed by Engineer-in-Charge. Notes: (i)The minimum 80 mm dia GI pole of 08 Mtrs long along with clamp, nut, bolt, washer to fix solar light rate deemed to be included on quoted rate.(ii) The earth work of excavation, PCC, Returning filling, Removal for install pole measured and paid separately.(iii) The ON/OFF control switch placed above 2.5 mtrs height of ground level. 97 Supply, laying, jointing and testing of HT cable 11000 volts grade and working voltage 24 KV of cross sectional area 95 Sqmm 3 Core as per IS-7098 (Part- I) 1988, ISI marked and make, RM of cable, CML No are imposed with insulating cover as well as printed on insulation, of XLPE insulated aluminium conductor heavy duty served with an inner sheathing PVC tape, galvanized steel strip or wire armoured with an overall PVC sheathing laid in trenches, fixed along the poles or passed through GI pipe using clamps wherever required laid under floors, road etc fixed concealed in walls encased in GI pipe connecting with suitable size of lugs and cable glands etc, each cable termination is to be made with suitable size of cable glands and aluminium thimbles for incoming and outgoing cables complete all as specified and directed by Engineer-in-Charge. 98 Note:(i) Earth work like excavation, Returning re filling, removal, sand cushioning, cable covers, GI pipe measured and paid separately under relevant item of schedule.(ii)Cable path indicators shall be provided at distance of every 100 metres and at cable joints and turning of all cables except for 2 core cables size and voltage written on it. The CI path indicator shall be fixed on MS angle iron. The cable path indicators shall be erected at the time of refilling the trenches and the cable path indicator shall be painted as under.(i) For HT 11 KV cables - “BROWN” 99 Supply ,Installation ,testing & commisioning of totally enclosedfeeder piller outdoor type(IP-65) fabricated out of 3.15 mm thick CRCA sheet dust and vermin proof powdercoated double door type(independent cabin including locking arrangementforeach MCCBs and provide space spreader for all MCCBs , bus bar chamber (enclosed) including locking arrangement complete suitable for operating on 415 Volt50 Hz AC, supply internally wired with copper conductor , TPN bus bar of aluminium strip (4 Nos) insulated by heat shrinkable sleaves & clips on shrouds for joints busbar shall be designed to withstand a fault lavel at 415 Volts having legs 45 cms made out of 65x65x6 mm angle iron grouted on brick masonary plateform upto 30 cms .Brick masonary plateform should be 60 cms abovethe Ground Level.Comprising the following : (LT Panel No 4 JCOs Mess)((i) The panel shall be front operated with cable entry from the bottem with cable glands. (ii) Fabrication of feeder piller box to be approved by CPRI width of the panel not less than 60cms Note:- Cost for construction of plateform for panel of brick masonary work in CM 1:6 with foundationPCC 1:4:8 type D-2including plaster work, PCC copping 1:2:4 (40 mm thick stone aggerate ), deemed to be included in the item rate.No extra payment will be made. 100 (Note: This panel shall be a front operated with cable entry from the bottom .The fault with standing capacity shall be 25 KA .Earth bus shall be part of the main feeder pillar.)(a) MCCB 4 pole, 100 A, 415 volt 50HZwith thermal setting 70% to 100% and rupturing capacity not less than 36 KA - 01 No (for Incoming).(b) MCCB 4 pole, 40 A, 415 volt 50HZ with thermal setting 70% to 100% and rupturing capacity not less than 16 KA - 01 No (for out going).(c ) MCCB 4 pole, 25 A, 415 volt 50HZ with thermal setting 70% to 100% and rupturing capacity not less than 16 KA - 02 Nos (for out going).(d)MCB SPN 6 to 32 amps 240 Volt- 01 Nos (outgoing)(e) Digital Ammeter 0 to 500 Amp with selector switch & suitable range of CTs - 01 No .(f) Digital Voltmeter 0 to 500 V with selector switch - 01 No.(g) LED Phase indicating lamp (Set of three)- 03 Nos (RYB) 101 Supply ,Installation ,testing & commisioning of totally enclosedfeeder piller outdoor type(IP-65) fabricated out of 3.15 mm thick CRCA sheet dust and vermin proof powdercoated double door type(independent cabin including locking arrangementforeach MCCBs and provide space spreader for all MCCBs , bus bar chamber (enclosed) including locking arrangement complete suitable for operating on 415 Volt50 Hz AC, supply internally wired with copper conductor , TPN bus bar of aluminium strip (4 Nos) insulated by heat shrinkable sleaves & clips on shrouds for joints busbar shall be designed to withstand a fault lavel at 415 Volts having legs 45 cms made out of 65x65x6 mm angle iron grouted on brick masonary plateform upto 30 cms .Brick masonary plateform should be 60 cms abovethe Ground Level.Comprising the following : (LT Panel No SM Barrick)(i) The panel shall be front operated with cable entry from the bottem with cable glands. (ii) Fabrication of feeder piller box to be approved by CPRI width of the panel not less than 60cmsNote:- Cost for construction of plateform for panel of brick masonary work in CM 1:6 with foundationPCC 1:4:8 type D-2including plaster work, PCC copping 1:2:4 (40 mm thick stone aggerate ), deemed to be included in the item rate. No extra payment will be made. 102 (Note: This panel shall be a front operated with cable entry from the bottom. The fault with standing capacity shall be 25 KA .Earth bus shall be part of the main feeder pillar.)(a) MCCB 4 pole, 400 A, 415 volt 50HZwith thermal setting 70% to 100% and rupturing capacity not less than 36 KA-01 No (for Incoming).(b) MCCB 3 pole, 63A, 415 volt 50HZ with thermal setting 70% to 100% and rupturing capacity not less than 16 KA - 06 Nos (for out going).(c ) MCCB 3 pole, 25A, 415 volt 50HZ with thermal setting 70% to 100% and rupturing capacity not less than 16 KA - 01 No (for out going).(d) MCB SPN 10-32 Amps, 10 KA , 240 v-01 No (for Outgoing)(e) Digital Ammeter 0 to 500 Amp with selector switch & suitable range of CTs - 01 No.(f) Digital Voltmeter 0 to 500 V with selector switch - 01 No.(g) LED Phase indicating lamp (Set of three)- 03 Nos (RYB) 103 Supply ,Installation ,testing & commisioning of totally enclosedfeeder piller outdoor type(IP-65) fabricated out of 3.15 mm thick CRCA sheet dust and vermin proof powdercoated double door type(independent cabin including locking arrangementforeach MCCBs and provide space spreader for all MCCBs, bus bar chamber (enclosed) including locking arrangement complete suitable for operating on 415 Volt50 Hz AC, supply internally wired with copper conductor , TPN bus bar of aluminium strip (4 Nos) insulated by heat shrinkable sleaves & clips on shrouds for joints busbar shall be designed to withstand a fault lavel at 415 Volts having legs 45 cms made out of 65x65x6 mm angle iron grouted on brick masonary plateform upto 30 cms .Brick masonary plateform should be 60 cms abovethe Ground Level.Comprising the following : (LT Panel No Laundary )(i) The panel shall be front operated with cable entry from the bottem with cable glands. (ii) Fabrication of feeder piller box to be approved by CPRI width of the panel not less than 60cms Note:- Cost for construction of plateform for panel of brick masonary work in CM 1:6 with foundationPCC 1:4:8 type D-2including plaster work ,PCC copping 1:2:4 (40 mm thick stone aggerate ) ,deemed to be included in the item rate .No extra payment will be made. 104 (Note: This panel shall be a front operated with cable entry from the bottom. The fault with standing capacity shall be 25 KA. Earth bus shall be part of the main feeder pillar.)(a) MCCB 4 pole, 200 A, 415 volt 50HZwith thermal setting 70% to 100% and rupturing capacity not less than 16 KA - 01 No (for Incoming) .(b) MCCB 3 pole, 160 A, 415 volt 50HZ with thermal setting 70% to 100% and rupturing capacity not less than 16 KA - 1 No (for out going).(c ) MCCB 3 pole,25, 415 volt 50HZ with thermal setting 70% to 100% and rupturing capacity not less than 16 KA - 03 Nos (for out going).(d)MCB SPN 6 to 32 amps 240 Volt- 06 Nos (outgoing)(e) Digital Ammeter 0 to 500 Amp with selector switch & suitable range of CTs - 01 No.(f) Digital Voltmeter 0 to 500 V with selector switch - 01 No.(g) LED Phase indicating lamp (Set of three)- 03 Nos (RYB) 105 Supply ,Installation ,testing & commisioning of totally enclosedfeeder piller outdoor type(IP-65) fabricated out of 3.15 mm thick CRCA sheet dust and vermin proof powdercoated double door type(independent cabin including locking arrangementforeach MCCBs and provide space spreader for all MCCBs , bus bar chamber (enclosed) including locking arrangement complete suitable for operating on 415 Volt50 Hz AC, supply internally wired with copper conductor , TPN bus bar of aluminium strip (4 Nos) insulated by heat shrinkable sleaves & clips on shrouds for joints busbar shall be designed to withstand a fault lavel at 415 Volts having legs 45 cms made out of 65x65x6 mm angle iron grouted on brick masonary plateform upto 30 cms .Brick masonary plateform should be 60 cms abovethe Ground Level.Comprising the following : (LT Panel No 5 near Offr Mess)(i) The panel shall be front operated with cable entry from the bottem with cable glands. (ii) Fabrication of feeder piller box to be approved by CPRI width of the panel not less than 60cms Note:- Cost for construction of plateform for panel of brick masonary work in CM 1:6 with foundationPCC 1:4:8 type D-2including plaster work ,PCC copping 1:2:4 (40 mm thick stone aggerate ) ,deemed to be included in the item rate .No extra payment will be made. 106 (Note: This panel shall be a front operated with cable entry from the bottom .The fault with standing capacity shall be 25 KA .Earth bus shall be part of the main feeder pillar.)(a) MCCB 4 pole, 250 A, 415 volt 50HZwith thermal setting 70% to 100% and rupturing capacity not less than 36 KA - 01 Nos (for Incoming) .(b) MCCB 3 pole 125 A, 415 volt 50HZ with thermal setting 70% to 100% and rupturing capacity not less than 16 KA - 01 No (for out going).(c) MCCB 3 pole 100 A, 415 volt 50HZ with thermal setting 70% to 100% and rupturing capacity not less than 16 KA - 01 No (for out going).(d) MCCB 3 pole 63 A, 415 volt 50HZ with thermal setting 70% to 100% and rupturing capacity not less than 16 KA -1 No (for out going).(e) MCCB 3 pole 32 A, 415 volt 50HZ with thermal setting 70% to 100% and rupturing capacity not less than 16 KA -1 No (for out going).(f) MCCB 3 pole 25 A, 415 volt 50HZ with thermal setting 70% to 100% and rupturing capacity not less than 16 KA - 04 Nos (for out going).(g)MCB SPN 6 to 32 amps 240 Volt - 12 Nos (out going)(h) Digital Ammeter 0 to 200 Amp with selector switch & suitable range of CTs - 01 No.(i) Digital Voltmeter 0 to 500 V with selector switch - 01 No.(j) LED Phase indicating lamp (Set of three)- 03 Nos (RYB) 107 Supply ,Installation ,testing & commisioning of totally enclosedfeeder piller outdoor type(IP-65) fabricated out of 3.15 mm thick CRCA sheet dust and vermin proof powdercoated double door type(independent cabin including locking arrangementforeach MCCBs and provide space spreader for all MCCBs, bus bar chamber (enclosed) including locking arrangement complete suitable for operating on 415 Volt50 Hz AC, supply internally wired with copper conductor , TPN bus bar of aluminium strip (4 Nos) insulated by heat shrinkable sleaves & clips on shrouds for joints busbar shall be designed to withstand a fault lavel at 415 Volts having legs 45 cms made out of 65x65x6 mm angle iron grouted on brick masonary plateform upto 30 cms .Brick masonary plateform should be 60 cms abovethe Ground Level.Comprising the following : (LT Panel No 6 near URC, FWC)(i) The panel shall be front operated with cable entry from the bottem with cable glands. (ii) Fabrication of feeder piller box to be approved by CPRI width of the panel not less than 60cms Note:- Cost for construction of plateform for panel of brick masonary work in CM 1:6 with foundationPCC 1:4:8 type D-2including plaster work ,PCC copping 1:2:4 (40 mm thick stone aggerate ) ,deemed to be included in the item rate .No extra payment will be made. 108 (Note: This panel shall be a front operated with cable entry from the bottom. The fault with standing capacity shall be 25 KA. Earth bus shall be part of the main feeder pillar.)(a) MCCB 4 pole, 160 A, 415 volt 50HZwith thermal setting 70% to 100% and rupturing capacity not less than 25 KA - 01 Nos (for Incoming) .(b) MCCB 3 pole 40 A, 415 volt 50HZ with thermal setting 70% to 100% and rupturing capacity not less than 16 KA -2 Nos (for out going).(c) MCCB 3 pole 25 A, 415 volt 50HZ with thermal setting 70% to 100% and rupturing capacity not less than 16 KA - 03 No (for out going).(d)MCB SPN 6 to 32 amps 240 Volt - 11 Nos (out going)(e) Digital Ammeter 0 to 200 Amp with selector switch & suitable range of CTs - 01 No.(f) Digital Voltmeter 0 to 500 V with selector switch - 01 No.(g) LED Phase indicating lamp (Set of three) - 03 Nos (RYB) 109 Supply ,Installation ,testing & commisioning of totally enclosedfeeder piller outdoor type(IP-65) fabricated out of 3.15 mm thick CRCA sheet dust and vermin proof powdercoated double door type(independent cabin including locking arrangementforeach MCCBs and provide space spreader for all MCCBs, bus bar chamber (enclosed) including locking arrangement complete suitable for operating on 415 Volt50 Hz AC, supply internally wired with copper conductor , TPN bus bar of aluminium strip (4 Nos) insulated by heat shrinkable sleaves & clips on shrouds for joints busbar shall be designed to withstand a fault lavel at 415 Volts having legs 45 cms made out of 65x65x6 mm angle iron grouted on brick masonary plateform upto 30 cms .Brick masonary plateform should be 60 cms abovethe Ground Level.Comprising the following : (LT Panel No 7 MT Area)(i) The panel shall be front operated with cable entry from the bottem with cable glands. (ii) Fabrication of feeder piller box to be approved by CPRI width of the panel not less than 60cmsNote:- Cost for construction of plateform for panel of brick masonary work in CM 1:6 with foundationPCC 1:4:8 type D-2including plaster work ,PCC copping 1:2:4 (40 mm thick stone aggerate ) ,deemed to be included in the item rate .No extra payment will be made. 110 (Note: This panel shall be a front operated with cable entry from the bottom. The fault with standing capacity shall be 25 KA. Earth bus shall be part of the main feeder pillar.)(a) MCCB 4 pole, 100 A, 415 volt 50HZwith thermal setting 70% to 100% and rupturing capacity not less than 25 KA - 01 Nos (for Incoming).(b) MCCB 3 pole 25 A, 415 volt 50HZ with thermal setting 70% to 100% and rupturing capacity not less than 16 KA - 03 Nos (for out going).(c)MCB SPN 6 to 32 amps 240 Volt - 05 Nos (out going)(d) Digital Ammeter 0 to 200 Amp with selector switch & suitable range of CTs - 01 No.(e) Digital Voltmeter 0 to 500 V with selector switch - 01 No.(f) LED Phase indicating lamp (Set of three) - 03 Nos (RYB) 111 Supply ,Installation ,testing & commisioning of totally enclosedfeeder piller outdoor type(IP-65) fabricated out of 3.15 mm thick CRCA sheet dust and vermin proof powdercoated double door type(independent cabin including locking arrangementforeach MCCBs and provide space spreader for all MCCBs, bus bar chamber (enclosed) including locking arrangement complete suitable for operating on 415 Volt50 Hz AC, supply internally wired with copper conductor , TPN bus bar of aluminium strip (4 Nos) insulated by heat shrinkable sleaves & clips on shrouds for joints busbar shall be designed to withstand a fault lavel at 415 Volts having legs 45 cms made out of 65x65x6 mm angle iron grouted on brick masonary plateform upto 30 cms .Brick masonary plateform should be 60 cms abovethe Ground Level.Comprising the following : (LT Panel No 8 LIFT)(i) The panel shall be front operated with cable entry from the bottem with cable glands. (ii) Fabrication of feeder piller box to be approved by CPRI width of the panel not less than 60cms Note:- Cost for construction of plateform for panel of brick masonary work in CM 1:6 with foundationPCC 1:4:8 type D-2including plaster work ,PCC copping 1:2:4 (40 mm thick stone aggerate ) ,deemed to be included in the item rate .No extra payment will be made. 112 (Note: This panel shall be a front operated with cable entry from the bottom .The fault with standing capacity shall be 25 KA .Earth bus shall be part of the main feeder pillar.)(a) MCCB 4 pole, 400 A, 415 volt 50HZwith thermal setting 70% to 100% and rupturing capacity not less than 25 KA - 01 Nos (for Incoming) .(b) MCCB 4 pole 100 A, 415 volt 50HZ with thermal setting 70% to 100% and rupturing capacity not less than 16 KA - 07 Nos (for out going).(c)MCB SPN 6 to 32 amps 240 Volt - 05 Nos (out going)(h) Digital Ammeter 0 to 200 Amp with selector switch & suitable range of CTs - 01 No.(d) Digital Voltmeter 0 to 500 V with selector switch - 01 No.(e) LED Phase indicating lamp (Set of three)- 03 Nos (RYB) 113 Security FencingConcertina coil 600mm dia, stretched to 6 RM, having 50 Nos spiral turns per 6 metrelength, spring co wire (2.59 mm thick ) of high tensile strength of 1620 N /sqm with tape (0.52 mm thick) Hot & galvanized upto 20 microns, weight of each coil 8.50 kg and fixing the same on Y-shaped angle iron with6 horizontal RBT (reinforced Barded Tape) wire, stud tied with GI clips to retain horizontal, clips shall be @ 5 Nos per 2 spiral turns approximate 125 clips per coil including necessary bolts complete all as specified and as directed by Engineer-in-Charge. 114 Construction steel gate of 5.5m wide and 3 m high with wicket gate 1.2 m wide and 3m high including RCC columns, painting steel surfaces in two coats over one coat of primer and two coat of colour wash over a coat of white wash to RCC column including excavation and earth work in any type of soil, RCC for columns, Reinforcement for columns and framed work, MS sheet for steel gate, complete all as specified and as directed by Engineer-in-Charge. 115 External Water supplyCutting the existing DI/CI water supply pipe line 150mm dia and inserting Tee 150x150x150 mm complete all as specified and as directed by Engineer-in-Charge. 116 Supply and lay pipe ductile Iron (Conforming to IS-8329-2000) with spigot and socket ends of bore 150 mm(6) diaspecial Class “K-9” including jointing material/joints laid in trenches complete all as specified and as directed by Engineer-in-Charge. 117 Construction of brick masonry valve chamber of internal dimensions 900 x 900 x 900 mm, bottom floor of the pit shall be constructed in PCC (1:3:6) 15 cm thick with 20 mm stone aggregate, inner and exposed surfaces and bottom floor of the pit should be plastered in CM (1:4) 15 mm thick. The top cover of the pit shall be made out of MS sheet min 3 mm thick with angle iron frame made out of MS angle 40 mm x 40 mm x 6 mm with 02 nossteel hinges and locking arrangements duly painted with two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and as directed by Engineer-in-Charge. 118 Supply and fix Air release valve 50 mm dia with two air outlets and fixing up in DI water supplymains complete all as specified and as directed by Engineer-in-Charge. 119 LIFTDesign supply, installation, testing & commissioning of 8 passenger lift, having 0.75 meter/second car speed, operate with Permanent Magnet Synchronous motor suitable for 3- Ph, 415V, 50Hz electric power supply, conforming to IS-14665, suitable to serve G + 03 upper floors with AC variable voltage & variable frequency drive (VVVF drive), complete with all standard accessories, simplex automatic & manual dual controlled operation with/without attendant, centre opening doors with door drive (electric motor driven mechanism), sliding stainless steel doors, automatic rescue device (ARD) system, 3D infrared sensor in full height of door & built in announcing system without hand set (04 Nos., one each in car, machine room & near ground floor landing door) complete all as specified and directed.The lift shall conform to the following technical specification.[i)Type of Lift: 8 Passenger[ii) Load Capacity: 544kg[iii)Speed 0.75 meter/second[iv]Type of Drive: AC Variable Voltage & Variable Frequency[v] Type of Machine: Gearless with PMSM (Permanent Magnet Synchronous Motor)[vi]Car Size: Not less than 1.43 m² 120 [vii]Car and Landing Door at all floors: Automatic center opening with VVVF door drive, opening size not less than 800X2000mm, sliding type, fabricated by stainless steel sheet not less than 16 gauge having hairline finish (N-304)[viii] Car Enclosure: Manufactured with stainless steel frame not less than 16 gauge with hairline finish (N304) having stainless false ceiling with hairline finish, internal lighting arrangement with LED light fittings operated on commercial supply and one LED light fitting operated on battery with invertor as emergency light complete internal ventilation system provided with concealed arial/ cross flow fan with auto cut-off system and stainless steel grill/ wire mesh for protection.[ix] Provision of standard thicknes stainless steel hand-rail 40mm diameter all around inside the car cabin.[x] Terminal Buffers: Metal special spring/PU/Oil buffers as per manufacturer specifications. The buffing stroke should not be less than 200mm.[xi] Door Opening (Inside): Protected by centre opening stainless steel doors with hairline finish doors with clear opening of 800X2000mm[xii] Car & Counter Weight Guide: Guide rails of MS T section as per OEM design; counter weight shall be as recommended by OEM[xiii] Flooring: 5mm thick Aluminium chequred plate / as per OEM design 121 [xiv] Signals:[a] Combined luminous hall buttonswith LED/ LCD /VFD hall position indicators at all floors[b] LED/LCD/VFD for car position indicator of stainless steel[c] One No. of car opening panel with luminous buttons in car (stainless steel)[d] Car direction indicator in car & landing[e] Battery operated alarm bell & emergency light (rechargable) along with suitable maintenance free battery (This system should be separate from ARD batteries.)[f]Overload warning feature in car cabin (display and announcing type both)[g] One firemans switch to be installed at ground floor near landing door[h] All signal fixture & car operating panel on hairline stainless steel face plate with hairline finish.[i] Infra red door sensor safety edge of door for entire height.[j] Built in announcing system without handset 2 Nos., one for lift car & ground floor landing door and one anouncing system with handset in machine room.[k] The interior of the car should be provided with a device that audibly announce the floor position of lift car has reached and announce that car entrance/ exit door is open or closed. 122 [xv] Safety Device:[a] Automatic rescue device (ARD)/automatic landing device operating with maintenance-free batteries having suitable capacity. The batteries must have auto charging facilities. The charger input be connected with converter of regerertive drive.[b] The ARD actuation time should be less than one second after failure of power supply and when ARD is operative the car should stop at the nearest floor and then open.[xvi] Operation: Simplex, full collective automatic operation with and without attendant.[xvii] Machine room: Located above the hoist way.Details as per building drawing[xviii] Civil work: Necessary Civil work viz. making good disturbed surfaces, modification to landing space to suit to car size, necessary foundation to machine etc.[xix] One number of wall mounted type telephone instrument of make installed inside of car cabin along with fixing arrangement and telephone cable of suitable size from car cabin to machine room run along with travelling cable. The telephone instrument shall be connected in the telephone DB installed in the machine room.[xx] The lift motor covered with suitable size of OEM recommended steel cover. 123 [xxi] To provide over speed Governor and its connected safety tongs as per OEM recommendation for control over speed if exceed 20% on assigned speed.[xxii] To provide fire sensor mode sensors and its assembly to lift during safety of fire.[xxiii] To provide overload sensors if load exceeds permissible limits the lift will not move and the over loads show in COP & LOP.[xxiv] The lift brakes should be designed as dual safety brakes.[xxv] The contractor should laision with state Lift inspector for making lift license and the lift inspector testing and visiting charges are deemed to be included on the quoted rate. The license issued by the state lift inspector should be submit the department and photocopy of license pasted on inside cabin without inspection of State Lift inspector the payemnt should not be made to contractor for all lift connected items.Provision of suitable size of copper conductor XLPE insulated cable from Lift Panel installed at Ground floor to machine room will deemed to be included the rate quoted by the contractor 124 Earthing complete with galvanized steel earth plate electrode 600x600x6mm thick buried in ground vertical to a depth not less than 2.25 mtrs deep below ground level with top edge of plate not less than 1.5mtr below normal ground level connected to galvanized GI earth galvanised iron strip of size 32×6mm and 40mm dia bore light grade GI protection pipe for earth strip and GI watering pipe 20 mm dia medium grade from the top edge of earth plate fixed with deep cut on one end of pipe and fix from earth plate up to one feet above ground level of other end and plugged watering pipe at top with MS cap and grouted in PCC 1:2:4 of size 30 X 30 X 30 CM etc and 15 CM alternate layer of charcoal and salt around all sides of earth plate all as shown in electric plate no 3 of SSR partI of 2009 complete all as specified and directed. 125 GI strip 20 x 3.0 mm with procelain insulators and fixing screws etc from earth pit to lift roomcomplete all as specified and as directed by Engineer-in-Charge. 126 Test point terminal block madeof gun metal or phosphorusbronze size 75x75x25mmdrilled and screwed including3 nos. 8mm dia 25mm longhex. head screwto connect earth stip and earthi stip mount suitable size of insulatorscomplete all as specified and as directed by Engineer-in-Charge. 127 Summer AppliancesSupply, installation testing and commissioning of heavy Duty Package Air Cooling Units, Top/ Down (Universal) Discharge with following features 4 inch thick imported high efficiency cellulose pads on 4 sides, optimized 3 Phase motor and fan to deliver the powerful air flow, water pump in wet section, cool flow dispenser for better coooling, auto connection of water tank to quick fill, water connection with ball valve, drain and overflow connection, weather resistat engineering plastic body with dust filter comprising of following capacity complete.Note : (i) The contractor should provide ducting passing drawing and cooling unit technical drawing to the department for approval.(ii) The package air cooler installed at G + 3 building and required T & P for positioning the 24 Nos of plant in top of the roof in six nos of G+3 building in various location in Samba Military Station deemed to be included on the quoted rate. 128 21000 CFM 129 13000 CFM 130 11000 CFM 131 9000 CFM 132 Supply, connection, testing and commissioning of flexible connection of material canvascomplete all as specified and as directed by Engineer-in-Charge. 133 Supply, installation, testing and commissioning of Factory Fabricated GI Sheet Spiral Oval/ Round Ducting with required Hardware Sheet 22 Gaugecomplete all as specified and as directed by Engineer-in-Charge. 134 Supply, installation, Testing and commissioningof Factory Fabricated GI Sheet Spiral Oval/Round Ducting with required HardwareSheet 24 Gauge complete all as specified and as directed by Engineer-in-Charge. 135 Supply and application of Acoustic treatment of ducts with 15 mm thick open cell, elastomeric nitrile rubber, of 140 Kg/m3 density dust free, fiber free, and CFC free insulation pasted inside the Duct with the help of adhesive complete all as specified and directed by Engineer-in-Charge. 136 Supply, installation, Testing and commissioning of Thermal Ductinsulation with 6MM Thick Aluminum Foil Faced XLPE Pasted on Duct with Rubber Adhesive complete all as specified and directed by Engineer-in-Charge. 137 Supply, installation, Testing and commissioning of SupplyAir Aluminum powder coated Linear Grill/Diffuserswith M.S. volume controlduct dampercomplete all as specified and as directed by Engineer-in-Charge. 138 Supply, installation, Testing and commissioning of Site Fabricated MS Angle Iron Stand for Ductable Air Cooling Unit with Black Enamel Paint, Including Lifiting & Placing of Air Washers complete all as specified and as directed by Engineer-in-Charge. 139 Supply Installation, Testing and Commissioning of 2.5sqmm x 4 Core Copper Cablingcomplete all as specified and as directed by Engineer-in-Charge. 140 Supply, installation, testing and commissioning of water connection with 2000 Ltrs Water tank PVC moduled & required accessories for evaporating ductable air cooling unitcomplete all as specified and as directed by Engineer-in-Charge. 141 Supply, laying 3 layer PP-R Polypropylene random co polymer concealed pipes of size 32 mm SDR 7.4 (PN 16) UV stabilized and antimicrobial fusion welded having thermal stability forcold water supply including all PP-R plain & brass threaded polypropylene random fittings fixed complete to walls, ceilings or in floors connected on water tank to air cooling unit and motorscomplete all as specified and as directed by Engineer-in-Charge. 142 PP-R Gate valves (brass inserted) of size 32 mm dia to connect the PP-R pipecomplete all as specified and as directed by Engineer-in-Charge. 143 Triple pole and earthencolsure with a threepin and earth plug withsocket complete withone triple pole MCB 40 -63 Ampscomplete all as specified and as directed by Engineer-in-Charge. 144 Supply, Installation, commissioning and testing of Refrigerator inverter type direct cool electricdriven (single phase) 240 volts, 50 Hz with inbuild voltage stabilizer of capacity 200 Ltrs BEE 5 star ratedcomplete all as specified and as directed by Engineer-in-Charge. 145 Supply, installation, commissioning and testing of Water cooler electric driven (single phase) having approx storage capacity of 80 Ltrs and nominal cooling capacity of 40 ltrs per hour complete all as specified and as directed by Engineer-in-Charge. 146 Supply, installation, commissioning and testing of Water cooler electric driven (single phase) having approx storage capacity of 120 Ltrs and nominal cooling capacity of 60 ltrs per hour complete all as specified and as directed by Engineer-in-Charge. 147 Supply, installation & commissioningand testing of desert cooler electric driven (single phase) having nominal air flow of capacity 3000 cum /hr with high efficiencyhoneycomb pad water capacity 75 Ltrs PVCbodycomplete all as specified and as directed by Engineer-in-Charge. 148 Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 2.0 KVA complete all as specified and as directed by Engineer-in-Charge. 149 Supply, Installation & commissioningof Glass top Deep freezer 320 Ltrs capacity having double door single phase complete all as specified and as directed by Engineer-in-Charge. 150 Note: The schedule of credit has been attached in tender in Pdf format as Sch A Part-XV and amount of credit schedule i.e. Rs 2006105.50 shall be deducted from the total amount of BOQ to arrive at the contract sum.
Contract Date: Dec 03, 2025 Contract Value : 48.48 Crore
Statutory Bodies & Commissions/Committees No of Bidders 12
Jammu And Kashmir View Result →
24.
Defence #8202257 AOC
Provn of transformer for ASC in North Camp, Provn of 15 mtr high mast lights in West Camp, Provn of electricity supply to shelters in East Camp and Spl repair to LT panels and connected works in North & South Camp at MFFR under AGE(I) MFFR.; 1 Supply and installation, testing and commissioning of transformer of capacity 250 KVAstep-down, Level-3, outdoor type copper wounded 11/0.433KV (at no load ) AC 3 phase, 50 HZ on secondary side double wound oil immersed naturallyair cooled with external cooling tubes/ radiator, delta connected as on primary and star connectedin accordance with vector group DYN-11 with neutral brought on secondary side and having tapping at (+/-) 2.5%, (+/-) 5%, (+/-) 7.5% to be changed by hand operated OFF LOAD tap changing gear. The maximum temperature rise should not exceed 45 degree centigrade in oil and 50 degree centigrade in HV/LV winding when measured by the resistance method after continuous full load run in ambient temperature the transformer shall conform to IS 2026. 1997 and comprising of following accessories:- 2 03 Nos porcelains HV bushing with arching horns on HV side suitable for 11 KV complete with bushing rods nuts. 3 01 No cable end box on LV secondary side consisting of 04 nos porcelain bushing with bushing rods and nuts washers and cable glands suitable for reception of 3.5 core 400sqmm cable, 2 runs, LT 1100 V grade XLPE insulated heavy duty including gland joint complete. 4 Oil conservator with filter type drain valve and oil level gauge. 5 Dehydrating breather with first filling of dehydrating agent. 6 Explosive vent. 7 THERMOMETER pocket. 8 Two earthing terminal on tank body to facilitate fixing of 32x6mm copper strips 9 One No thermometer dial type vapour pressure type having range 0-120 degree centigrade with maximum temperature indicator and re-setting device to maximum temperature including needle of temperature gauge : Max reading painted terminal. 10 Rating plate with terminal plate. 11 Oil level gauge. 12 Oil filling hole on top cover with plug. 13 Air release valve/plug. 14 4 Nos plain solid cast steel detachable rollers. 15 Extra bushing for neutral outside the cable box and providing independent earthing for neutral. 16 First fill of transformer oil conforming to IS 1180 and tested upto 60KV dielectric strength. 17 M&L for platform for transformer of size 3.0x3.0x1.5m high from GL including excavatiion in trenches not less than 1 mtr, PCC 1:5:10 type E2 for foundation, brick work in CM 1:6, PCC 1:2:4 type B1 in coping, plaster 10mm thick in CM 1:6, PCC 1:2:4 type B1 , 100mm thick as in flooring using extra cement over 75mm thick PCC 1:4:8 type B1 sub base, including returning filling , removal of surplus soil, 2 Nos ISMB 100mm channel for fixing transformer and fancing of transforner including ramp of suitable size mounting of transformer complete all as specified and as directed 18 M&L for Prestressed concrete pole, 11 metres long, 152 mm x 152 mm at top and 152 mm x 260 mm at bottom,class 9 including painting with two coats of synthetic enamel paint (in alternate black & white/yellow strips of 30 cm height) upto 1.5 meter height from top of PCC coping and also including numbering to poles with synthetic enamel paint on black base of size 15 cm x 10 cm and numbering in 8 cm height of number with white paint incl required iron channels/clamps/GI pipe for the protection of flexible cable connecter box with bus bars, bolts & nuts complete all as specified and as directed. 19 Supply, installing and testing of Lightning arresters expulsion type complete with all fittings, transmission class, discharge capacity 65 Kilo Amp capacity suitablefor 11 KV complete all as specified and as directed. 20 M&L for Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections, including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete all as specified and as directed. 21 S&F Switch air break, gang operated outdoor, Horizontal operatedtype, HT 11 KV, Triple pole, 200 Amps, 3 insulator per phase, tilting/rocking horizontal type, with fixed contacts of phosphorous bronze and moving contacts of copper, manually operated from ground level with operating mechanism including GI tubing medium grade 25 mm bore operating rod, pad locking arrangements, MS arcing horns, flexible braiding earthing blades, rod and contacts without drop out fuse assembly and jumpers with Mink conductor line, taps, clamps, colour coated HT sleeves and fittings suitable for horizontal mounting, complete all as specified and as directed. 22 M&L for Danger notice plate of size 25cm x 20 cm x 3 mm thick of mild steel sheet, vitreous, enameled white, with letters, figures and conventional skull & bones in signal red colour and fixed with MS clamps made out of 25mm x 3mm MS flat iron including bolts and nuts of approved size for HT 11000 volts, complete all as specified and as directed. 23 S&F Anti-climbing device spikes type fabricated out of M.S. bars (round, square and flat) including nuts, bolts, washers and welding in two halves made to shape to suit the cross section of the pole complete all as specified and as directed. 24 Supply, laying & testing of XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty)with stranded aluminum conductor,11000V grade, of cross section area95 sq mm 3 core complete all as specified and as directed. 25 S&F cable jointing kit for 11 KV grade (Earthed) cable for outdoor terminal heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE, armoured, Al conductor cable of 95 sq mm,outdoor complete all as specified and as directed. 26 M&L for Cable route indicator showing HT Cable and route/joint of cable with arrow made of PCC 1X2X4 type B1 duly rendered with plaster 10 mm thick of size 40 X50X20cm fixed and erected on PCC plateform of sixe 40X40X10 CM goruted in grounts duly painted on both sides with HT Cable Route complete all as specified and as directed. 27 Supply, laying and testing of cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor complete all as specified and as directed of following sizes:- 28 185 Sqmm 3.5 core. 29 150 Sqmm 3.5 core. 30 120 Sqmm 3.5 core. 31 95 Sqmm 3.5 core. 32 70 Sqmm 3.5 core. 33 50 Sqmm 3.5 core. 34 35 Sqmm 3.5 core. 35 35 Sqmm 2 core. 36 25 Sqmm 4 core . 37 25 Sqmm 2 core. 38 16 Sqmm 4 core. 39 16 Sqmm 2 core. 40 Excavating in trenches, not exc 1.5 metre wide and not exc 1.5 metre in depth, for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, laying cables, pipes, etc. not exc 10 Sqm on plan & not exc 1.5m in depth and getting out in soft/loose soil complete all as specified and as directed. 41 Returning, filling in, including spreading, leveling watering and well ramming in layers not exc 25 cm thick in soft/loose soil complete all as specified and as directed. 42 Removing excavated soil/material to a distance not exc 50 metre and depositing where directed at a level not exc 1.50 metre above the starting point complete all as specified and as directed. 43 All as per Srl item No. 15 here in before but exc 1.5m and not exceeding 3.0 in depth complete all as specified and as directed. 44 Boring of holes under road, pavement, hard standingby manually without damaging of road, material & labour includingpipe 80 mm dia suitablecomplete all as specified and as directed.Note; length of pipe to be measured and paid seperately under relavant item. 45 M&L for PCC 1:4:8 type D2 using 40mm graded crushed stone aggregate as in foundations of poles, filling, mass concrete and similar works, complete all as specified and as directed.Note : Volume of pole/strut embedded in concrete shall be deducted for the purpose of payment. 46 M&L for cement concrete 1:2:4 type B1 using 20mm graded crushed stone aggregate as in copings, pedestal of poles and the like including use and waste of form work (straight or curved), all exposed surface of concrete finished even & smooth without using extra cement, complete all as specified & as directed.Note : Volume of pole/strut embedded in concrete shall be deducted for the purpose of payment. 47 S&F GaIvanised steel tubes of size 80mm, light grade with all fittings laid in trenches complete including cutting and thereading all as required at site complete all as specified and as directed. 48 S&F double wall corrigated pipe of outer dia 120mm and inner dia 103 mm for cable protection as per IS-16205 complete all as specified and as directed. 49 All as per Srl item No. 21 here in before but outer dia 50mm and inner dia 38 mm complete all as specified and as directed. . 50 Supplying and laying synthetic insulating rubber mat for electrical installations, ISI marked of IS:15652 and of size 2 mtr x 1 mtr x 2.5 mm suitable for 11 KV system complete all as dirceted. 51 Supply, installing, commissioning and testing of LT panel board outdoor type,cubical type made out CRCA sheet 3.15 mm thick dust and vermin proof and panel shall be mounted on angle iron frame andlegs made from angle of size 50x50x6mm, pedestal flame grouted in PCC (1:2:4) type B-1 20 mm graded stone aggregated thimble and cable entry boxes with cable glands. Panel should covered from all sides with front and back lockable door and hinges complete with aluminum bus bar of 600Amprs,coil CT ratio100/5A,(in separate chamber) including painting with two coats synthetic enameled paint over a coat of red oxide primer and consisting of the following:- 52 MCCB400 Amp , 4 pole,36 kA-01 Each . 53 MCCB250Amp , 4 pole,36 kA -02 Each. 54 MCCB160Amp , 4 pole,36 kA -01 Each. 55 Digital Amp meter (0-600)-01 Each. 56 Digital Volt meter (0-500) -01 Each. 57 RYB Indicator-01 Set. 58 Supply, installing, commissioning and testingof LT BUs Barboard outdoor type,cubical type made out CRCA sheet 3.15 mm thick dust and vermin proof and angle iron of suitable size, pedestal flame grouted in PCC (1:2:4) type B-1 20 mm graded stone aggregated thimble and cable entry boxes with cable glands. Panel should covered from all sides with front and back lockable door and hinges complete with aluminum bus bar of 300Amprs,coil CT ratio 100/5A with provision of 6 way outgoing connection ,(in separate chamber) including painting with two coats synthetic enameled paint over a coat of red oxide primer and consisting of the following:- 59 On load change over switch 250A. 60 MCCB160Amp , 4 pole,36 kA -02 Incoming (Main & DG Supply). 61 Digital Amp meter (0-250)-01 Each. 62 Digital Volt meter (0-500) -01 Each. 63 RYB Indicator-01 Set. 64 Supply, installing, testing and commissioning of factory made floor mounted LT cubical panel confrming to CPRI specification board out type (double door) made out of 3.15mm thick CRCA sheet totally enclosed with necessary ventilations, weather, dust and vermin proof IP-53 minium with front and rear opening and locking arrangement 415Volts, 3 phase, 50 Hz having aluminium bus bar of capacity 125Amps and of suatable size to house all LT switch gears and accusories as mentianed below and full neutral duly colour coded and for neutral supported with DMC/SMC insulators colour codedcomplete connection from bus bar to MCCB with suitable copper cable, panel board shall be grouted in the ground with suitable size of foundation in PCC 1:2:4 type B1, MS channels for base frame 50x50x6 mm and supports, GI nut, bolts, washers etc.The panel board shall be powder coated and red oxided primed :- 65 The following items are provided in one compartment :-(i)Digital Voltmeter - 01 No, (ii)Digital Ameter - 01 No (iii)Three Indication LED Lamp 66 Incomming - 67 MCCB 4P, 63AMP, 25 KA -01 No 68 Out going :- 69 (i)RCCBFOR EARTH LEAKAGE, OVERLOAD & SHORT- CIRCUIT PROTECTION 4P,100mA, 40 Amp -05 Nos,(ii) onload change over 100A FP-01 70 M&L for Earthing to Transformer / GOD switch / equipments / panels etc with & including galvanised mild steel earth plate electrode of size 60 cm x 60 cm x 6 mm thick buried vertically in ground (earth pit not less than2.25 m below normal ground level) with top edge of the earth plate at a depth not less than 1.5 m below ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides, connected to & including galvanized mild steel strip 32x6 mm as earth lead, including nuts, bolts, check nuts & washers of galvanized iron or steel and riveted/welded to earth plate at one end and other end of strip connected to transformer / GOD / Panel / equipment body / test point with two Nos nuts bolts or welding with steel structure, GI earth strip encased in and including 40mm bore GI light grade pipe with all fittings from upper edges of earth plate upto 7.5 metre above ground level fixed with and including providing watering pipe 20mm bore GI pipe medium grade from earth pit to top of electrode and including funnel, wire mesh, copper lugs etc complete with earth pit in PCC 1:3:6 type C1 using 20mm graded crushed stone aggregate and 40mm thick RCC (1:2:4 type B1) cover complete all as specified and shown in electrical plate No 3 of SSR Part-I including necessary excavation and earthwork in any type of soil, returning, filling in approved soil and disposal of surplus soil to a distance not exc 50m complete all as specified and as directed including dismantling & taking out old existing unserviceable earthing.Note : PCC chamber shall be constructed at least 1.5 mtr away from the earth electrode and pipe for watering shall be provided in slanting manner. 71 M & L in replacement for Earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6 mm thick, buried directly in ground (earth pit not less than 2.25 metre depth below normal ground level) with top edge of plate at a depth not less than 1.5 mtr below ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides, connected to galvanized earth wire 04 mm dia with and including bolts, nuts, check nuts and washers of galvanised iron or steel and riveted to earth plate and one end and connecting to main switch board or metallic bodies of HT/LT equipments etc at the other end, GI wire encased in and including 15 mm bore GI light grade pipe with all fittings, from top of electrode to body of equipment fixed with and includingflatiron clamps, bolts, nuts and washer and also including providing watering pipe 20mm bore GI light grade and including funnel, wire mesh, copper lugs etc from bottom of earth pit to top of electrode complete with earth pit in PCC 1:3:6 type C-2 using 40 mm graded crushed stone aggregate and CI cover complete all specified and shown in electrical plate No 03 of SSR Pt-I connecting earth electrode to test point with and including earthing lead including neessary excavation and earthwork in any type of soil, returning, filling in approved soil and disposal of surplus soil to a distance n.exc 50m, material and labour complete all as specified and as directed. 72 M&L for GI strip of size 32x6mm as earth continuity conductor burried in ground or drawn in pipe or fixed to wall on saddle complete all as specified and as directed. 73 M&L for cable end box jointing kit suitable for LT UG cable of size 16 Sq mm 3½ core to 25 sqmm3½ core including cuting,stripping the cable and connection etc complete all as specified and as directed. 74 M&L for cable end box jointing kit suitable for LT UG cable of size 95 Sq mm 3½ core to 150 sqmm3½ core including cuting,stripping the cable and connection etc complete all as specified and as directed. 75 M&L for 40mm graded coarse stone aggregate, deposited, spread and leveled in layers not exc 15 cm thick, rammed to a true surface, under 2/4 pole structure and around the 2/4 pole structure & outdoor electrical installations, complete all as specified and as directed. 76 M&L for Brick work with fly ash bricks old size straight or curved on plan exceeding 6m mean radius built in CM 1:6 complete all as specified and as directed. 77 Supply & installation of Galvanized steel high mast lighting system of 16 meter in two section hot dip galvanised as per BS - 729 in single dip with logitudinal weld and without any circumferential weld, suitable for wind velocity 180 KMPH as per IS : 875/1987 (Pt-III)3 mm section thickness, top dia 150 mm,bottom dia 300 mm . It shall also include accessories of high mast including head frame cast aluminium pully suitable for trailing cable and wire ropes with bush bearing and stainless steel spindle povided with guides, separators and adjustor to prevent ropes and cables with 2/3 wire rope system and its accessories. Pully assembly to be housed in chasis integral with 6 mm 316 grade ss hoisting ropes of 7/19 construction hacing factor of safety more than 5 in the TR No.7 rope for 2 wire rope. DD type winches having both end with factory fitted talunt and thimble. Copper cripping with single drum winch galvanised lantern carriage arrangement suitable for 6/9 luminaries symmetrically and control gear box and lightening finial pole design BS 5649 CP-3 steel grade BSEN shape mast shall be hexagonal including the following:-(a) Provision of construction of RCC foundation as per manufucture requirement for 15 mtr high mast bolt, bolt dipped galvanised high tensile stud with nut ,washer, anchor plate to cast into the foundation is suppliedfor each mast complete template is provided for precise setting the bolts. 78 (b) Errection commissioning of the high mast with the help of suitable T&P/Equipment.(c) Design and casting of suitable shallow foundation as per manufacture requirement with M-25 design mix concrete for the high mast.(d) Twin dome LED aviation light luminari comprising of aluminium hosing with polycarbonate enclosure and LED lamp.(e) Control panel suitable for switching and up-down operation of mast including suiatble size digital voltmete and ammeter with built in selector switch, CTs and indicator lamps.(f) Copper Trailing cable 5 core 2.5 sqmm of suitable length as required for installation of high mast. (g) Manual and electric operation Non flame proof integral motor as per manufacturer design with gears, rope, double drum winch andmovable lantern carriage for up and down operation.(h) Wiring of fixture with copper wire 3 core 1.5 sqmm, flexible conduit and copper lug. Note :Contractor shall be submitt the high mast drawing with foundation detail as per menufracture for approval of accepting officer. 79 Supply and fixing in replacement of LED based Flood lights, housing made of pressure die cast aluminium alloy with effective thermal management sturdiness. The fixture should have a minimum system efficacy of more than 110 lumen/Watt and a minimum system lumen output of not less than 7600 lumens and maximum system wattage 170 watts.The fuxture shall have a color temperature of minimum 5700 k at a CRI of minimum 70.The fixture shall be designed for a system life of 50,000 hours @ 70% lumen maintenance, lngress protection of IP66 (lamps and gear compartment and Mechanical Impact) Resistance Rating of IK>= 05.The fixture should comply with the parameters as per IEC 60598 and IS 10322, and LED drive should apply to IEC 61000-3-2 ed 3.2. per haronics IEC 61347-2-13, 2006 in confirmation with IEC 61347-1 ed, 2.0, 2007 for electrical safety, LM 79 and LM 80 test report needs to be sumittedabove parameters.The fixture driver should have an operating voltage range of 140-300V, frequency 50-60 Hz, surge protection not less than 4KV, PF>0.95 and THD<15%.The driver should have double phase protection.LED lights fitting should be suitable for ambient temperature from (-) 10 digree C to (+) 50 digree C, including street light GI bracket 40 mm dia bent to shape 1200and down 15mm Bore GI pipe with GI clamps with junction box for fixing LED lightrequired, with suitable size clamp, nut bolts and washers as per site requirement complete all as specified as directed. (Note-The manufacture of LED fitting shall give Guarantee for 2 years from the date of installation and complete fixed with suitable bracket & Accessories). 80 M&L for Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below normal ground level surrounded from all sides by 15 cm thick packed layer of charcoal dust and common salt filling in alternate layers and electrode connections by using galvanised iron strip 25×4mm as earthing leadby means of bolts, nuts check nuts and washers of GI or steel and connecting to earthing test point, main switch board, testing on completion includingGI pipe 20 mm dia mediumgrade for watering and bringing the same upto 30 cm above normal ground level with plug at top including pipe fittings etc complete and GI pipe 40 mm dia light grade for the protection of GI strip from earth pit to earth point complete including necessary excavation and earth work in any type of soil, returning, filling in approved soil and disposal of surplus soil to a distance n.exc 50 m all as specified as shown in electrical plate No 2 SSR Part-I complete all as specified and as directed. 81 M&L for installation, commissioning & testing of LT panel board (outdoor type) double door fabricated 3.15 mmthick CRCA sheet, duly powder coated,dust and vermin proof, totally enclosed metal clad, cubicle type accessible from front and rear side both with locking arrangement 3 phase 4 wire system at AC 440 volts, 50 Hz, indoor type applied with two coats of vsynthetic enamelled paint and mounted on angle iron of size 50x50x6 mm grouted in PCC foundation and suitable to house the following accessories;- 82 Aluminium bus bar of capacity duly covered with colour coded shrinkable sleeves not less than 200 Amps for phase and 100 Amps for neutral - 01 set. 83 Voltmeter AC 3 phase, 415 volt, digital type flush pattern 0-500 volts with selector switch- 01 No. 84 Panel indicating lamp neon/LED type (red,yellow&blue) with lamp holders - 03 Nos. 85 Panel internal wiring with FRLS2.5 Sqmm copper wire single core - 01Job. 86 MCCB 63 Amps, 4 pole Make- Legrand ( as incoming ) -01 No. 87 MCB 63 Amps TPNMake- Legrand ( as outgoing ) -01 No. 88 Contactor of capacity 32 Amps Make- L &T - 02 Nos. 89 S&F of automatic street light switch using infrared sensor based Nture Switch-, 25 kw equally distributed,63 Amps,3-pole,Model - Swadeep-02 EC 25 Kw3Pfor automatic switching of street lights based on LUX level of natural light . The sensor(Nature switch ) along with suitable power contactorrating 63 Amps 3- pole & 40 Amps 2-pole, MCB SP 63 Amps -03 nosand support terminals should be enclosed in pole/wall mountable enclosure made of rust proof ,electric shock proof, termite proof and FR grade SMC Junction box (Sintex make) confirming to IP54.The contactor suitable to 3- phaseload of 25 kw , rating 63 amps 3pole, MCB rating 63 amps SP 03 NOs complete all as specified and as directed. 90 S&F of double wall corrigated pipe of outer dia 77mm and inner dia 63 mm for cable protection as per IS-16205 complete all as specified and as directed. 91 S&F factory made Octogonal Hot rolled steelpole confirming to IS 2062/BSEN 10025 with hot dipped galvanised finishing of 7 mtr long with mild steel base plate grouted alongwith foundation by means of 04 Nos M20 x 600 LG foundation bolts including single swan neck backet and one MCB for switching the light on and off inside the pole complete all as specified and as directed. Note:- (i) Excavation,earth work shall be measured and paid separately under appropriate Sch.(ii) RCC M-20 and steel for foundation shall be as per OEM recommendation and drawing which shall be deemed to be included in the quoted rate. 92 S&F of 35Watt LED street light fitting of following Wattage 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and as directed. 93 M&L for Cable PVC insulated PVC unsheathed un-armoured flexible copper conductor (multi stranded) of cross sectional area 2.5 sqmm 2 core all as required for connections to light fittings complete all as specified and as directed. 94 Supply, installing, commissioning and testing of LT panel outdoor type,double door front and back both openable, cubical type made out CRCA sheeet 3.15 mm thick dust and vermin proof and angle iron of suitable size, pedestal flame grouted in PCC (1:2:4) type B-1 20 mm graded stone aggregated thimble and cable entry boxes with cable glands, bus bar should covered from all sides with front and back , complete with 200 Amps (3phase) & 200 Amp (Neutral) rated aluminium bus bar of suitable size, including painting with two coats synthetic enameled paint over a coat of red oxide primer and consisting of the following:- 95 MCCB 100 Amp, 4 pole, 415 V, 25 KA-01 Each (01 In-coming). 96 Digital Amp meter (0-250) -01 Each. 97 Digital Volt meter (0-500)-01 Each. 98 RYB Indicator -01 Set. MCB TPN 63A FP-02 Nos Outgoing. 99 M&L for Earthing complete with galvanized steel perforated pipe electrode 40mm boreburied directly in ground (earth pit not less than 2.25 meters deep below ground level) with top edge of the plate not less than 1.5 meter below normal ground level connected to galvanized iron strip 32x6mm as earthing lead by means of bolts, nuts, check nuts and washer of galvanized iron or steel all as shown in electrical plate No 3 of SSR Part-I connected to panel/pole/bus bar complete all as specified and testing on completion, including provision of earth wire protected by 40mm dia GI light grade protection pipe from test point to main board and 20mm GI medium grade watering pipe funnel, PCC earth pit and RCC cover charcoal, salt and GI wire including excavation and earth work etc complete all as specified and as directed. 100 Supply, errection,commisioning and testing in replacement ofLT panel pillar box cubical type ofcomprising size (Panel box size), with bus bar chamber having 4 wire 415 Volts, CPRI type tested factory made dust proof vermin proof for out door use made out of CRCA sheet 3.15 mm thick powder coated, machine pressed, both side opening with double door (front & rear) in two shalves with provision of rubber beadings and locking system, danger Notice board infront and rear sides including insulated aluminium bus bar of 1.6 times of main incomming MCCB capacity in Amp, 4 stripmounted on porcelain insulator, bus bar chamber shall be provided with inspection covers, each MCCB/ cubical switch shall have be independent opening , panel shall be mounted on angle iron frame andlegs made from angle of size 50x50x6mm , frame and legs duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer, legs grouted in PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) complete including all connections/control wiring incoming/out going with suitable size of copper conductor cable complete.Foundation is not less than 30 cm below ground level and not less than 45 cm above ground level, legs of panels will be grouted in centre of PCC foundation centre place will be open for connection of Under ground cables complete all as specified and as directed including provision of following :- 101 (i) MCCB 400 Amp Adjustable thermal setting 36 KA, FP, single frame, thermal magnetic trip (incoming) - 01 Nos. (ii) MCCB 125 Amp Adjustable thermal setting 35 KA, FP, single frame, thermal magnetic trip(Outgoing) - 04 Nos. (iii) MCB SPN 40 Amp(Outgoing) - 02 Nos.(iv) on load Changeover - FP 200Amp(Outgoing) - 01 No. (v) Digital Voltmeter with built inselector switch 0-500 volts -1 No.(vi) Digital Ampmeter with built inselector switch 0-250 Amps with Suitable CTs -1 No.(vii) LED indicating Lamps ( R,Y,B) one set-01 No. 102 All as per Serial Item No 45 here-in-before but with provision of following:-(i) MCCB 160 Amp Adjustable thermal setting 36 KA, FP, single frame, thermal magnetic trip (incoming) - 01 No. (ii) MCCB 125 Amp Adjustable thermal setting 35 KA, FP, single frame, thermal magnetic trip(Outgoing) - 05 Nos. (iii) MCB SPN 40 Amp(Outgoing) - 02 Nos. (iv) Digital Voltmeter with built inselector switch 0-500 volts -1 No.(v) Digital Ampmeter with built inselector switch 0-250 Amps with ratio 100:5 CTs -1 No.(vi) LED indicating Lamps ( R,Y,B) one set-01 No. 103 All as per Serial Item No 45 here-in-before but with provision of following:- (i) MCCB 200 Amp Adjustable thermal setting 36 KA, FP, single frame, thermal magnetic trip (incoming) - 01 No. (ii) MCCB 125 Amp Adjustable thermal setting 35 KA, FP, single frame, thermal magnetic trip(Outgoing) - 04 Nos. (iii) MCB SPN 40 Amp(Outgoing) - 02 Nos . (iv) on load Changeover - FP 200 Amp (Outgoing) - 01 No.(v) Digital Voltmeter with built inselector switch 0-500 volts -1 No.(vi) Digital Ampmeter with built inselector switch 0-250 Amps with ratio 100:5 CTs -1 No.(vii) LED indicating Lamps ( R,Y,B) one set-01 No. 104 All as per Serial Item No 45 here-in-before but with provision of following:-(i) MCCB 63 Amp Adjustable thermal setting 25 KA, FP, single frame, thermal magnetic trip (incoming) - 01 Nos (ii) MCB SPN 63 Amp(Outgoing) - 05 Nos (iii) On load Changeover - FP 63 Amp (Outgoing) - 01 Nos (iv) Digital Voltmeter with built inselector switch 0-500 volts -1 No(v) Digital Ampmeter with built inselector switch 0-250 Amps with Suitable CTs -1 No(vi) LED indicating Lamps ( R,Y,B) one set-01
Contract Date: Nov 04, 2025 Contract Value : 88.98 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 12
25.
Defence #8184022 AOC
Tender For Replacement Of Water Supply Pipe Line Inside Cantt 600000 Gallon Water Treatment Plant At 20 Camp Pump House Under Ge Ramgarh; 2 SCHEDULE A PART-I A (Building Work)Design (Hydraulically, architecturally, structurally and aesthetically) and construction of underground sump of 30000 gallon (UK) capacity including with permanent specification RCC M30 (Design Mix) excavation in all type of strata foundation concrete container walls, bottom lab, local sump & foundation for pump/pipes, top RCC roof slab with C manhole covers, all surfaces are plaster with WPC including epoxy paint inside (bottom & sides) including all pipeline connections, valves, MS ladder, ventilation shaft and testing of water tightness and hydraulic functioning complete and necessary internal water supply & electrical suplly. Arch drawing of sump and WTP (site plan) approved by CWE/GE 3 Sch A Part-I B (Water Treatment Plant)Design (Architecturally, hydraulically, aesthetically and structurally), construting, commissioning and testing of water treatment plant 600000 gallons complete all as specified and directed. 4 NOTE : The basic requrement of Water Treatment Plant is as under for guidline :Design (Architecturally, hydraulically, aesthetically and structurally), construting, commissioning and testing of conventional water treatment plant 600000 gallons including cost of providing and applying epoxy paint to inside surface of water retaining structure in contact with chlorine and providing anti termite treatment to entire structure below ground level, Mechanical and electrical components of various sub-works as specifiedin scope of work, Design Basis Report, elsewhere in tender : including necessary hydraulic testing, structural testing, equipment testing and trial run for 03 months etc. complete including all pumping machinery all as specified and directed by Engr-in-charge and as per latest technolony and govt & this dept policy for portable water treatment plant. Treated water parameters for drinking water is as per IS 10500 :2012(Second Revision). Raw water value is enclosed as appx A 5 Sch A Part-II (External Water supply)Lump sum price worked out by the contractor for ExternalWater Supply as listed in Schedule A Part-II against the lump sum price inserted by the MES. 6 Sch A Part-III(Road, Path and Culvert)Lump sum price worked out by the contractor for Road Path and Culvert as listed in Schedule A Part-IV against the lump sum price inserted by the MES. 7 Sch A Part-IV(Sewage Disposal)Lump sum price worked out by the contractor for Sewage Disposal as listed in Schedule A Part-V against the lump sum price inserted by the MES. 8 Sch A Part-V(Demolition & Dismantling)Lump sum price worked out by the contractor for Demolition & Dismantling as listed in Schedule A Part-VII against the lump sum priceinserted by the MES. 9 Sch A Part-VI(Site clearance, excavation & earth works)Lump sum price worked out by the contractor for Site clearance, excavation & earth works as listed in Schedule A Part-VII against the lump sum priceinserted by the MES. 10 Note for Srl No 2 to 9The percentage above / below the SSR -2020 (part-II) rates shall be derived from the amount quoted by the contractor against Srl No. 2 to 9by comparing it with the amount inserted / pre- priced by the department and the same shall be applicable for the items of respective schedule 11 Schedule A Part-VII (Miscellaneous works) 12 Sewage Disposal 13 Item No 01 : Soakage wells 1.20 M dia X 3.0 M effective depth, excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size 40 mm to 63 mm as specified and directed.(Drg No. BTD - 744) 14 Item No 02 : M&L for LDPE septic tank designed to carry sewage and sullage water, with upflow filter incoming media excavation in any type of soil, PCC 1:4:8 below foundation, etc with vent shaftof 10 users complete all as per manufacturer instructions. 15 External Water Supply 16 Item No 03 : Supply, Laying in trenches 150 mm nominal diaductile iron pressure pipe, for water mains centrifugally cast with spigot and socket ends (for push on joints), Class K-9 of standard length 5.5 mtr complete all as specified and as directed. Note- Rubber gasket joints (push on joints) shall be measured and paid separately. 17 Item No 04 : All as per item No 03 here-in-before but 200 mm dia 18 Item No 05 : All as per item No 03 here-in-before but 250 mm dia 19 Item No 06 : M & L for rubber gasket joints (push on joints) for spigot/ socket end ductile iron water mains/ductile iron specials complete for 150 mm nominal dia complete all as specified and as directed. 20 Item No 07 : All as per item No 06 here-in-before but 200mm dia 21 Item No 08 : All as per item No 06 here-in-before but 250mm dia 22 Item No 09 : Supply and fix DI special suitable for DI pipe class K-9 upto 300 mm dia complete all as specified and as directed. 23 Item No 10 : Construction of mesonary valve pit chamber with burnt brick (Sub class B) in cement mortor (1:6) and 10 mm thick plastering in CM1:4 and PCC (1:4:8) type D-2 in foundation bed or size internally climent on 1500 mm x 1500 mm x 1500 mm with 3 mm thick MS sheet cover with locking arrangement hinged with 40 x 40 x 5 mm angle iron frame embeded in PCC (1:3:6) type C-1 etc including painting with two coats of synthetic enamel paint over a coat of red oxide primer to all steel surfaces completed including earth work all as specified and directed. 24 Manning & Operation for 02 Years During Defect Liability Period: 25 Mate Fitter General Mechanic (FGM) (Semi-skilled) - 02 NO in each shift (total - 06 Nos FGM (Semi-skilled) 03 shifts) 26 Item No 11 : Manning & Operation for 1st year during DLP: Providing services of daily maintenance, manning & operation with fitter general mechanic mate FGM (Semi-skilled) to water supply installation located at 20 Camp Pump House consisting of centrifugal pumps, aeration fountain, floculator, clarifier, rapid sand filter, UG sump of cap 25000 gallon, chlorination system, OHT of cap 100000 gallon round the clock in Three shifts (Morning, Evening & Night), including sundays & holidays each shift of 08 hours starting from 0600 Hrsincluding daily checking and rectifying leakges and operating the raising, delivery, washout and overflow pipes, valves, pit chambers and operating pumping sets during supply with any minor repair required like replecement of gland, tightening of terminations, inspect motor vents and windings for dust/dirt build-up and clean accordingly, inspect starter/ contractor for arcing, lubricate the pump the motor bearing on regular intervals, oiling and greasing etc of equipments for smooth trouble free functioning all as directed by Engineer-in-Charge. 27 Note: (a) Duty o tradesmen in addition to above is to operate the installation & provide uninterrupted water supply to the stn and report to JE/AGE during breakdown/fault(b) The term Daily Operation includes Minor Maintenance like General Clearing, Cleaning of Machines, Equipments and Hourly Reading, Recording of Each Plant, Log Sheet)s) will be provided by the contractor to all equipments of pump house in standard proforma to make record in consultation with engineer-in-charge. (c) Protective clothing as per IS and safty instructions are to be provided by the contractor and will be continuously in use of the operator on duty. No extra payment shall be made to the contractor for the same (d) SHIFT DUTY (TIMINGS):- (I) MORNING SHIFT : 0600 to 1400 Hours, (ii) Evening Shift : 1400 Hours to 2200 Hours, (iii) Night Shift: 2200 HOurs to 0600 Hours. 28 DETAILS OF WATER SUPPLY INSTALLATION:-(a) Centrifugal pumping sets including connected starter - 02 Nos (b) Aeration fountain(c) Flocculator (d) Clarifier(e) Rapid sand filter (Min 02 Nos)(f) Chlorine dosing plant - 01 No (g) Control electrical panel boards of centrifugal pump sets(h)OHT of cap 100000 gallon 29 Note for ser Item No 11 (i) Operator / Technical / attendent of proper trade with ITI qualified having minimum 04 years of experience in their respective field. (ii) Contractor shall produce all qualification & experience certificates, photos and police verification to all operators / technician before commencement of this contract to engr-in-charge. After verification & satisfaction of engr-in-charge operator/ technician shall deployed to E&M installation. 30 (iii) Replacement of minor parts such as flare nuts, LT cable joints with suitable size lugs, pump glands etc are contractors responsibility complete all as specified by engineer-in-charge.(iv) It is the responsibility of AGE/JE to ensure that attendance register is maintained at all the installation duty signed kept on record and payment of trade men for the Nos of days present will only be made GE will responsible for payment of trade men in aadhar linked accountcontractor shall be provide proper dress to tradesmen as approved by Eng-in-charge and during duty hours all tradesmen shall be in proper uniform otherwise necessary recovery @ double the quoted rate for per day shall be made from his dues. 31 (v) In case the contractor does not operate any one of installation for a day or part thereof due to any reason whatsoever double of the quoted rate to eachday will be recovered.(vi) Leave of deployed person in inescapable cases shall be allowed on prior intimation but contractor on demand of engineer-in-charge, shall arrange alternate arrangment. Payment shall not be allowed for leave period.(vii) in no case wages of deployed persons shall be less than the minimum wages fixed by govt competent authority. It is mandatory requirement fdor contractor that payment of deployed person shall be made through cheque/ RTGS/Acceptable Electronic mode only proof of payment shall be submitted by contractor to engineer in charge monthaly basis or during claming on account of advance (RAR) / FB. 32 (viii) The Employees Provident Funds & Miscellaneous Provisions (EPF & MP) Act, 1952, shall be strictly adhered to by the contractor, social security to workers i.e. EPF, ESIC, Personal insurance (If applicable) on part of Employer shall be paid by contractor and accordingly, contractor/Bidder shall include all these factors in his quoted rate.(ix) statuatory levies/GST if applicable on part of contracts shall be paid by contractor and accordingly, contractor/ Bidder shall include all these factors in his quoted rate.(x) Deployed person shall report daily to JE/Engineer in charge or nominated officers by Accepting officer for their attendence & obtain instructions. An attendence register shall be maintained by contractor on site. 33 (xi) T&P = working Tools/plants, protective cloths, communication & conveyance arrangments shall be provided by contractor at his own cost.(xii) An uniform of blue shirt/jersy duly embossed MES OUTSOURCING SERVICES at back and name plate of the person on front left shall be provided by contractor to all workers at his own cost.(xiii) Documentation - Attendance registr & wages register, Daily work register as per the format provided by the Deptt. shall be prepared & maintained at his own cost. 34 (xiv) Contractor shall make security pass for all operators and maintain proper register duly signed by all concerned.(xv) If quoted rates are less than minium fair wages inclusive of GST, EPF, ESIC as applicable the bid shall be treated as non-bonafide and will be rejected. No objection/clain in this regard will be accepted (xvi) Scope of work shall include physical chemical and bacteriological analysis of water, samples to be collected each month by a rep of contractor and carefully taking the sample to Test Laboratory and handing over the sample and collection of test report in stipulated time period and submitting the repost to this office every month. 35 Item No 12 : Manning & Operation for 2nd year during DLP: Providing services of daily maintenance, manning & operation with fitter general mechanic mate FGM (Semi-skilled) to water supply installation located at 20 Camp Pump House consisting of centrifugal pumps, aeration fountain, floculator, clarifier, rapid sand filter, UG sump of cap 25000 gallon, chlorination system, OHT of cap 100000 gallon round the clock in Three shifts (Morning, Evening & Night), including sundays & holidays each shift of 08 hours starting from 0600 Hrs including daily checking and rectifying leakges and operating the raising, delivery, washout and overflow pipes, valves, pit chambers and operating pumping sets during supply with any minor repair required like replecement of gland, tightening of terminations, inspect motor vents and windings for dust/dirt build-up and clean accordingly, inspect starter/ contractor for arcing, lubricate the pump the motor bearing on regular intervals, oiling and greasing etc of equipments for smooth trouble free functioning all as directed by Engineer-in-Charge. 36 Note: (a) Duty o tradesmen in addition to above is to operate the installation & provide uninterrupted water supply to the stn and report to JE/AGE during breakdown/fault(b) The term Daily Operation includes Minor Maintenance like General Clearing, Cleaning of Machines, Equipments and Hourly Reading, Recording of Each Plant, Log Sheet)s) will be provided by the contractor to all equipments of pump house in standard proforma to make record in consultation with engineer-in-charge. (c) Protective clothing as per IS and safty instructions are to be provided by the contractor and will be continuously in use of the operator on duty. No extra payment shall be made to the contractor for the same (d) SHIFT DUTY (TIMINGS):- (I) MORNING SHIFT : 06 : 0600 Hours, (ii) Evening Shift : 1400 Hours to 2200 Hours, (iii) Night Shift: 2200 HOurs to 0600 Hours. 37 DETAILS OF WATER SUPPLY INSTALLATION:-(a) Centrifugal pumping sets including connected starter - 02 Nos (b) Aeration fountain(c) Flocculator (d) Clarifier(e) Rapid sand filter (Min 02 Nos)(f) Chlorine dosing plant - 01 No (g) Control electrical panel boards of centrifugal pump sets(h)OHT of cap 100000 gallon 38 Note for ser Item No 12 (i) Operator / Technical / attendent of proper trade with ITI qualified having minimum 04 years of experience in their respective field. (ii) Contractor shall produce all qualification & experience certificates, photos and police verification to all operators / technician before commencement of this contract to engr-in-charge. After verification & satisfaction of engr-in-charge operator/ technician shall deployed to E&M installation. 39 (iii) Replacement of minor parts such as flare nuts, LT cable joints with suitable size lugs, pump glands etc are contractors responsibility complete all as specified by engineer-in-charge.(iv) It is the responsibility of AGE/JE to ensure that attendance register is maintained at all the installation duty signed kept on record and payment of trade men for the Nos of days present will only be made GE will responsible for payment of trade men in aadhar linked accountcontractor shall be provide proper dress to tradesmen as approved by Eng-in-charge and during duty hours all tradesmen shall be in proper uniform otherwise necessary recovery @ double the quoted rate for per day shall be made from his dues. 40 (v) In case the contractor does not operate any one of installation for a day or part thereof due to any reason whatsoever double of the quoted rate to eachday will be recovered.(vi) Leave of deployed person in inescapable cases shall be allowed on prior intimation but contractor on demand of engineer-in-charge, shall arrange alternate arrangment. Payment shall not be allowed for leave period.(vii) in no case wages of deployed persons shall be less than the minimum wages fixed by govt competent authority. It is mandatory requirement fdor contractor that payment of deployed person shall be made through cheque/ RTGS/Acceptable Electronic mode only proof of payment shall be submitted by contractor to engineer in charge monthaly basis or during claming on account of advance (RAR) / FB. 41 (viii) The Employees Provident Funds & Miscellaneous Provisions (EPF & MP) Act, 1952, shall be strictly adhered to by the contractor, social security to workers i.e. EPF, ESIC, Personal insurance (If applicable) on part of Employer shall be paid by contractor and accordingly, contractor/Bidder shall include all these factors in his quoted rate.(ix) statuatory levies/GST if applicable on part of contracts shall be paid by contractor and accordingly, contractor/ Bidder shall include all these factors in his quoted rate.(x) Deployed person shall report daily to JE/Engineer in charge or nominated officers by Accepting officer for their attendence & obtain instructions. An attendence register shall be maintained by contractor on site. 42 (xi) T&P = working Tools/plants, protective cloths, communication & conveyance arrangments shall be provided by contractor at his own cost.(xii) An uniform of blue shirt/jersy duly embossed MES OUTSOURCING SERVICES at back and name plate of the person on front left shall be provided by contractor to all workers at his own cost.(xiii) Documentation - Attendance registr & wages register, Daily work register as per the format provided by the Deptt. shall be prepared & maintained at his own cost. 43 (xiv) Contractor shall make security pass for all operators and maintain proper register duly signed by all concerned.(xv) If quoted rates are less than minium fair wages inclusive of GST, EPF, ESIC as applicable the bid shall be treated as non-bonafide and will be rejected. No objection/clain in this regard will be accepted (xvi) Scope of work shall include physical chemical and bacteriological analysis of water, samples to be collected each month by a rep of contractor and carefully taking the sample to Test Laboratory and handing over the sample and collection of test report in stipulated time period and submitting the repost to this office every month. 44 Item No 13 : Manning & Operation for 3rd year (To commence from next day of comletion DLP): Providing services of daily maintenance, manning & operation with fitter general mechanic mate FGM (Semi-skilled) to water supply installation located at 20 Camp Pump House consisting of centrifugal pumps, aeration fountain, floculator, clarifier, rapid sand filter, UG sump of cap 25000 gallon, chlorination system, OHT of cap 100000 gallon round the clock in Three shifts (Morning, Evening & Night), including sundays & holidays each shift of 08 hours starting from 0600 Hrs including daily checking and rectifying leakges and operating the raising, delivery, washout and overflow pipes, valves, pit chambers and operating pumping sets during supply with any minor repair required like replecement of gland, tightening of terminations, inspect motor vents and windings for dust/dirt build-up and clean accordingly, inspect starter/ contractor for arcing, lubricate the pump the motor bearing on regular intervals, oiling and greasing etc of equipments for smooth trouble free functioning all as directed by Engineer-in-Charge. 45 Note: (a) Duty o tradesmen in addition to above is to operate the installation & provide uninterrupted water supply to the stn and report to JE/AGE during breakdown/fault(b) The term Daily Operation includes Minor Maintenance like General Clearing, Cleaning of Machines, Equipments and Hourly Reading, Recording of Each Plant, Log Sheet)s) will be provided by the contractor to all equipments of pump house in standard proforma to make record in consultation with engineer-in-charge. (c) Protective clothing as per IS and safty instructions are to be provided by the contractor and will be continuously in use of the operator on duty. No extra payment shall be made to the contractor for the same (d) SHIFT DUTY (TIMINGS):- (I) MORNING SHIFT : 06 : 0600 Hours, (ii) Evening Shift : 1400 Hours to 2200 Hours, (iii) Night Shift: 2200 HOurs to 0600 Hours. 46 DETAILS OF WATER SUPPLY INSTALLATION:-(a) Centrifugal pumping sets including connected starter - 02 Nos (b) Aeration fountain(c) Flocculator (d) Clarifier(e) Rapid sand filter (Min 02 Nos)(f) Chlorine dosing plant - 01 No (g) Control electrical panel boards of centrifugal pump sets(h)OHT of cap 100000 gallon 47 Note for ser Item No 13 (i) Operator / Technical / attendent of proper trade with ITI qualified having minimum 04 years of experience in their respective field. (ii) Contractor shall produce all qualification & experience certificates, photos and police verification to all operators / technician before commencement of this contract to engr-in-charge. After verification & satisfaction of engr-in-charge operator/ technician shall deployed to E&M installation. 48 (iii) Replacement of minor parts such as flare nuts, LT cable joints with suitable size lugs, pump glands etc are contractors responsibility complete all as specified by engineer-in-charge.(iv) It is the responsibility of AGE/JE to ensure that attendance register is maintained at all the installation duty signed kept on record and payment of trade men for the Nos of days present will only be made GE will responsible for payment of trade men in aadhar linked accountcontractor shall be provide proper dress to tradesmen as approved by Eng-in-charge and during duty hours all tradesmen shall be in proper uniform otherwise necessary recovery @ double the quoted rate for per day shall be made from his dues. 49 (v) In case the contractor does not operate any one of installation for a day or part thereof due to any reason whatsoever double of the quoted rate to eachday will be recovered.(vi) Leave of deployed person in inescapable cases shall be allowed on prior intimation but contractor on demand of engineer-in-charge, shall arrange alternate arrangment. Payment shall not be allowed for leave period.(vii) in no case wages of deployed persons shall be less than the minimum wages fixed by govt competent authority. It is mandatory requirement fdor contractor that payment of deployed person shall be made through cheque/ RTGS/Acceptable Electronic mode only proof of payment shall be submitted by contractor to engineer in charge monthaly basis or during claming on account of advance (RAR) / FB. 50 (viii) The Employees Provident Funds & Miscellaneous Provisions (EPF & MP) Act, 1952, shall be strictly adhered to by the contractor, social security to workers i.e. EPF, ESIC, Personal insurance (If applicable) on part of Employer shall be paid by contractor and accordingly, contractor/Bidder shall include all these factors in his quoted rate.(ix) statuatory levies/GST if applicable on part of contracts shall be paid by contractor and accordingly, contractor/ Bidder shall include all these factors in his quoted rate.(x) Deployed person shall report daily to JE/Engineer in charge or nominated officers by Accepting officer for their attendence & obtain instructions. An attendence register shall be maintained by contractor on site. 51 (xi) T&P = working Tools/plants, protective cloths, communication & conveyance arrangments shall be provided by contractor at his own cost.(xii) An uniform of blue shirt/jersy duly embossed MES OUTSOURCING SERVICES at back and name plate of the person on front left shall be provided by contractor to all workers at his own cost.(xiii) Documentation - Attendance registr & wages register, Daily work register as per the format provided by the Deptt. shall be prepared & maintained at his own cost. 52 (xiv) Contractor shall make security pass for all operators and maintain proper register duly signed by all concerned.(xv) If quoted rates are less than minium fair wages inclusive of GST, EPF, ESIC as applicable the bid shall be treated as non-bonafide and will be rejected. No objection/clain in this regard will be accepted (xvi) Scope of work shall include physical chemical and bacteriological analysis of water, samples to be collected each month by a rep of contractor and carefully taking the sample to Test Laboratory and handing over the sample and collection of test report in stipulated time period and submitting the repost to this office every month. 53 Item No 14 : Comprehensive maintenance, (To commence from next day Expiry of DLP) servicing and repairs of water treatment plant 600000 gallons alongwith cleaning of spray nozzles of aeration fountion, scrubbing of parshall flume so as to keep the flow surfaces clean of surface buildup or algae growth, deep cleaning the flash mixer by washing the attachment, dewatering the flocculator completely and cleaning its channels and removal of flocs deposit by any means, removal of sludge deposition in clarifier and depositing the sludge at a certain distance so as to avoid contamination to clear water, backwashing of rapid sand filters, cleaning of solution tanks for any deposition, ewatering the UG sump of capacity 2500 gallon and cleaning its interior surface for algae deposition if any, opening the valves and cleaning it and refixing in original state, cleaning of pipeline connetions and fixing the leakages if any all as directed by engineer- in - charge. 54 Item No 15 : Manning & Operation for 4th year (To commence from next day of comletion of item no.-13): Providing services of daily maintenance, manning & operation with fitter general mechanic mate FGM (Semi-skilled) to water supply installation located at 20 Camp Pump House consisting of centrifugal pumps, aeration fountain, floculator, clarifier, rapid sand filter, UG sump of cap 25000 gallon, chlorination system, OHT of cap 100000 gallon round the clock in Three shifts (Morning, Evening & Night), including sundays & holidays each shift of 08 hours starting from 0600 Hrs including daily checking and rectifying leakges and operating the raising, delivery, washout and overflow pipes, valves, pit chambers and operating pumping sets during supply with any minor repair required like replecement of gland, tightening of terminations, inspect motor vents and windings for dust/dirt build-up and clean accordingly, inspect starter/ contractor for arcing, lubricate the pump the motor bearing on regular intervals, oiling and greasing etc of equipments for smooth trouble free functioning all as directed by Engineer-in-Charge. 55 Note: (a) Duty o tradesmen in addition to above is to operate the installation & provide uninterrupted water supply to the stn and report to JE/AGE during breakdown/fault(b) The term Daily Operation includes Minor Maintenance like General Clearing, Cleaning of Machines, Equipments and Hourly Reading, Recording of Each Plant, Log Sheet)s) will be provided by the contractor to all equipments of pump house in standard proforma to make record in consultation with engineer-in-charge. (c) Protective clothing as per IS and safty instructions are to be provided by the contractor and will be continuously in use of the operator on duty. No extra payment shall be made to the contractor for the same (d) SHIFT DUTY (TIMINGS):- (I) MORNING SHIFT : 0600 Hours to 1400 Hours, (ii) Evening Shift : 1400 Hours to 2200 Hours, (iii) Night Shift: 2200 HOurs to 0600 Hours. 56 DETAILS OF WATER SUPPLY INSTALLATION:-(a) Centrifugal pumping sets including connected starter - 02 Nos (b) Aeration fountain(c) Flocculator (d) Clarifier(e) Rapid sand filter (Min 02 Nos)(f) Chlorine dosing plant - 01 No (g) Control electrical panel boards of centrifugal pump sets(h)OHT of cap 100000 gallon 57 Note for ser Item No 15 (i) Operator / Technical / attendent of proper trade with ITI qualified having minimum 04 years of experience in their respective field. (ii) Contractor shall produce all qualification & experience certificates, photos and police verification to all operators / technician before commencement of this contract to engr-in-charge. After verification & satisfaction of engr-in-charge operator/ technician shall deployed to E&M installation. 58 (iii) Replacement of minor parts such as flare nuts, LT cable joints with suitable size lugs, pump glands etc are contractors responsibility complete all as specified by engineer-in-charge.(iv) It is the responsibility of AGE/JE to ensure that attendance register is maintained at all the installation duty signed kept on record and payment of trade men for the Nos of days present will only be made GE will responsible for payment of trade men in aadhar linked accountcontractor shall be provide proper dress to tradesmen as approved by Eng-in-charge and during duty hours all tradesmen shall be in proper uniform otherwise necessary recovery @ double the quoted rate for per day shall be made from his dues. 59 (v) In case the contractor does not operate any one of installation for a day or part thereof due to any reason whatsoever double of the quoted rate to eachday will be recovered.(vi) Leave of deployed person in inescapable cases shall be allowed on prior intimation but contractor on demand of engineer-in-charge, shall arrange alternate arrangment. Payment shall not be allowed for leave period.(vii) in no case wages of deployed persons shall be less than the minimum wages fixed by govt competent authority. It is mandatory requirement fdor contractor that payment of deployed person shall be made through cheque/ RTGS/Acceptable Electronic mode only proof of payment shall be submitted by contractor to engineer in charge monthaly basis or during claming on account of advance (RAR) / FB. 60 (viii) The Employees Provident Funds & Miscellaneous Provisions (EPF & MP) Act, 1952, shall be strictly adhered to by the contractor, social security to workers i.e. EPF, ESIC, Personal insurance (If applicable) on part of Employer shall be paid by contractor and accordingly, contractor/Bidder shall include all these factors in his quoted rate.(ix) statuatory levies/GST if applicable on part of contracts shall be paid by contractor and accordingly, contractor/ Bidder shall include all these factors in his quoted rate.(x) Deployed person shall report daily to JE/Engineer in charge or nominated officers by Accepting officer for their attendence & obtain instructions. An attendence register shall be maintained by contractor on site. 61 (xi) T&P = working Tools/plants, protective cloths, communication & conveyance arrangments shall be provided by contractor at his own cost.(xii) An uniform of blue shirt/jersy duly embossed MES OUTSOURCING SERVICES at back and name plate of the person on front left shall be provided by contractor to all workers at his own cost.(xiii) Documentation - Attendance registr & wages register, Daily work register as per the format provided by the Deptt. shall be prepared & maintained at his own cost. 62 (xiv) Contractor shall make security pass for all operators and maintain proper register duly signed by all concerned.(xv) If quoted rates are less than minium fair wages inclusive of GST, EPF, ESIC as applicable the bid shall be treated as non-bonafide and will be rejected. No objection/clain in this regard will be accepted (xvi) Scope of work shall include physical chemical and bacteriological analysis of water, samples to be collected each month by a rep of contractor and carefully taking the sample to Test Laboratory and handing over the sample and collection of test report in stipulated time period and submitting the repost to this office every month. 63 Item No 16 : Comprehensive maintenance, (To commence from next day of comletion of item no -14) servicing and repairs of water treatment plant 600000 gallons alongwith cleaning of spray nozzles of aeration fountion, scrubbing of parshall flume so as to keep the flow surfaces clean of surface buildup or algae growth, deep cleaning the flash mixer by washing the attachment, dewatering the flocculator completely and cleaning its channels and removal of flocs deposit by any means, removal of sludge deposition in clarifier and depositing the sludge at a certain distance so as to avoid contamination to clear water, backwashing of rapid sand filters, cleaning of solution tanks for any deposition, ewatering the UG sump of capacity 2500 gallon and cleaning its interior surface for algae deposition if any, opening the valves and cleaning it and refixing in original state, cleaning of pipeline connetions and fixing the leakages if any all as directed by engineer- in - charge. 64 Item No 17 : Manning & Operation for 5th year (To commence from next day of comletion of item no. 15): Providing services of daily maintenance, manning & operation with fitter general mechanic mate FGM (Semi-skilled) to water supply installation located at 20 Camp Pump House consisting of centrifugal pumps, aeration fountain, floculator, clarifier, rapid sand filter, UG sump of cap 25000 gallon, chlorination system, OHT of cap 100000 gallon round the clock in Three shifts (Morning, Evening & Night), including sundays & holidays each shift of 08 hours starting from 0600 Hrs including daily checking and rectifying leakges and operating the raising, delivery, washout and overflow pipes, valves, pit chambers and operating pumping sets during supply with any minor repair required like replecement of gland, tightening of terminations, inspect motor vents and windings for dust/dirt build-up and clean accordingly, inspect starter/ contractor for arcing, lubricate the pump the motor bearing on regular intervals, oiling and greasing etc of equipments for smooth trouble free functioning all as directed by Engineer-in-Charge. 65 Note: (a) Duty o tradesmen in addition to above is to operate the installation & provide uninterrupted water supply to the stn and report to JE/AGE during breakdown/fault(b) The term Daily Operation includes Minor Maintenance like General Clearing, Cleaning of Machines, Equipments and Hourly Reading, Recording of Each Plant, Log Sheet)s) will be provided by the contractor to all equipments of pump house in standard proforma to make record in consultation with engineer-in-charge. (c) Protective clothing as per IS and safty instructions are to be provided by the contractor and will be continuously in use of the operator on duty. No extra payment shall be made to the contractor for the same (d) SHIFT DUTY (TIMINGS):- (I) MORNING SHIFT : 0600 Hours to 1400 Hours, (ii) Evening Shift : 1400 Hours to 2200 Hours, (iii) Night Shift: 2200 HOurs to 0600 Hours. 66 DETAILS OF WATER SUPPLY INSTALLATION:-(a) Centrifugal pumping sets including connected starter - 02 Nos (b) Aeration fountain(c) Flocculator (d) Clarifier(e) Rapid sand filter (Min 02 Nos)(f) Chlorine dosing plant - 01 No (g) Control electrical panel boards of centrifugal pump sets(h)OHT of cap 100000 gallon 67 Note for ser Item No 17 (i) Operator / Technical / attendent of proper trade with ITI qualified having minimum 04 years of experience in their respective field. (ii) Contractor shall produce all qualification & experience certificates, photos and police verification to all operators / technician before commencement of this contract to engr-in-charge. After verification & satisfaction of engr-in-charge operator/ technician shall deployed to E&M installation. 68 (iii) Replacement of minor parts such as flare nuts, LT cable joints with suitable size lugs, pump glands etc are contractors responsibility complete all as specified by engineer-in-charge.(iv) It is the responsibility of AGE/JE to ensure that attendance register is maintained at all the installation duty signed kept on record and payment of trade men for the Nos of days present will only be made GE will responsible for payment of trade men in aadhar linked accountcontractor shall be provide proper dress to tradesmen as approved by Eng-in-charge and during duty hours all tradesmen shall be in proper uniform otherwise necessary recovery @ double the quoted rate for per day shall be made from his dues. 69 (v) In case the contractor does not operate any one of installation for a day or part thereof due to any reason whatsoever double of the quoted rate to eachday will be recovered.(vi) Leave of deployed person in inescapable cases shall be allowed on prior intimation but contractor on demand of engineer-in-charge, shall arrange alternate arrangment. Payment shall not be allowed for leave period.(vii) in no case wages of deployed persons shall be less than the minimum wages fixed by govt competent authority. It is mandatory requirement fdor contractor that payment of deployed person shall be made through cheque/ RTGS/Acceptable Electronic mode only proof of payment shall be submitted by contractor to engineer in charge monthaly basis or during claming on account of advance (RAR) / FB. 70 (viii) The Employees Provident Funds & Miscellaneous Provisions (EPF & MP) Act, 1952, shall be strictly adhered to by the contractor, social security to workers i.e. EPF, ESIC, Personal insurance (If applicable) on part of Employer shall be paid by contractor and accordingly, contractor/Bidder shall include all these factors in his quoted rate.(ix) statuatory levies/GST if applicable on part of contracts shall be paid by contractor and accordingly, contractor/ Bidder shall include all these factors in his quoted rate.(x) Deployed person shall report daily to JE/Engineer in charge or nominated officers by Accepting officer for their attendence & obtain instructions. An attendence register shall be maintained by contractor on site. 71 (xi) T&P = working Tools/plants, protective cloths, communication & conveyance arrangments shall be provided by contractor at his own cost.(xii) An uniform of blue shirt/jersy duly embossed MES OUTSOURCING SERVICES at back and name plate of the person on front left shall be provided by contractor to all workers at his own cost.(xiii) Documentation - Attendance registr & wages register, Daily work register as per the format provided by the Deptt. shall be prepared & maintained at his own cost. 72 (xiv) Contractor shall make security pass for all operators and maintain proper register duly signed by all concerned.(xv) If quoted rates are less than minium fair wages inclusive of GST, EPF, ESIC as applicable the bid shall be treated as non-bonafide and will be rejected. No objection/clain in this regard will be accepted (xvi) Scope of work shall include physical chemical and bacteriological analysis of water, samples to be collected each month by a rep of contractor and carefully taking the sample to Test Laboratory and handing over the sample and collection of test report in stipulated time period and submitting the repost to this office every month. 73 Item No 18 : Comprehensive maintenance, servicing and repairs of water treatment plant 600000 gallons alongwith cleaning of spray nozzles of aeration fountion, scrubbing of parshall flume so as to keep the flow surfaces clean of surface buildup or algae growth, deep cleaning the flash mixer by washing the attachment, dewatering the flocculator completely and cleaning its channels and removal of flocs deposit by any means, removal of sludge deposition in clarifier and depositing the sludge at a certain distance so as to avoid contamination to clear water, backwashing of rapid sand filters, cleaning of solution tanks for any deposition, ewatering the UG sump of capacity 2500 gallon and cleaning its interior surface for algae deposition if any, opening the valves and cleaning it and refixing in original state, cleaning of pipeline connetions and fixing the leakages if any all as directed by engineer- in - charge. 74 Item No 19 : RCC hume pipe NP-2 1500 mm dia laid over 100 mm thick PCC type B-1, 1:2:4 over 100 mm thick PCC type E2 1:5:10, vertically. The top cover of valve pit chamber shall be covered with MS sheet 1.25 mm thick with MS Angle iron 40 x 40x 6 mm thick frame and MS angle iron 30 x 30 x 6 mm thick for shutter frame & flat iron 40 x 6 mm bracing with M.S. sheet. All MS item shall be painted with two coat o synthetic enamel paint over a coat of red oxide primer. 75 Item No 20 : MS pipe 40 mm dia (medium grade) @ 1.0 m spacing and 850 mm long) and MS pipe 25 mm dia (Medium grade) - 3 Row duly painted provided to coat of synthetic enamel paint over coat a red oxide primer, railing to be provided to every items/ Part of water treatment plant. 76 SCHEDULE A(Schedule of credit)Schedule of Credit Rs 994845.00 (Minus) inserted by the MES.(Note : Credit amount shall be deducted manually to arrive net bid amount)
Contract Date: Oct 31, 2025 Contract Value : 5.41 Crore
Statutory Bodies & Commissions/Committees No of Bidders 9
26.
Defence #8124169 AOC
Tender For Repair/Maintenance Of Ht Protection And Control System, Ht Distribution Network At Mathura Under Ge (East) Mathura.; 1 Disconnecting & taking out33KV HT VCB/SF6 Breaker of any description and any make of rating 400/630/1200Amp, dismantling / opening of the VCB for preventive maintenance / servicing / overhauling, taking out and removing unserviceable / defective parts includingcleaning & servicing, greasing, oiling of the parts etc and renewal of unserviceable parts with new one, re-assembling the VCB after overhauling / servicing and its testing complete and renewal of following unserviceable spare parts of make as approved by GE complete all as specified and directed.Notes :- (i) The quoted rate of contractor includes for fixing the serviceable parts in position and renewal of unserviceable parts with new parts.(ii) The new parts shall be measured and paid separately under appropriate item as supply only mentioned here-in-after(iii) Servicing to be carried out by service engineer of OEM. 2 Supply only Shunt trip coil 24-30 Volts DC suitable for 33KV VCB 3 Supply only Switch TNC (trip, neutral, close) 4 Supply and fixing after disconnected of electric supply to VCB and replace the unserviceable Over current and earth fault protection relay, Vx=24 -240 V AC/24-250 V DC,In=1A/5A(0,1In-40In), Ion=1 A/5A(0,01Ion-2Lon) complete all as specified and directed. Make:-Cat part No REL15002D Easergy P1 of Schneider/ABB/Siemes Note:- Fixing of protection relay shall be carried out through O.E.M of maanufacturers engineer/technician only . 5 Disconnecting & taking out11KV HT VCB of any description and any make of rating 400/630Amp, dismantling / opening of the VCB for preventive maintenance / servicing / overhauling, taking out and removing unserviceable / defective parts includingcleaning & servicing, greasing, oiling of the parts etc and renewal of unserviceable parts with new one, re-assembling the VCB after overhauling / servicing and its testing complete and renewal of following unserviceable spare parts of make as approved by GE complete all as specified and directed. Notes :- (i) The quoted rate of contractor includes for fixing the serviceable parts in position and renewal of unserviceable parts with new parts.(ii) The new parts shall be measured and paid separately under appropriate item as supply only mentioned here-in-after(iii) Servicing to be carried out by service engineer of OEM or authorised dealer 6 Supply only Vaccum bottle suitable for 630 Amp, 11KV HT VCB 7 Supply only Vaccum bottle suitable for 400 Amp, 11KV HT VCB 8 Supply only Fixed arcing contact assembly suitable for 630 Amp 11KV HT VCB 9 Supply only Moving arcing contact assembly suitable for 630 Amp 11KV HT VCB 10 Supply only Fixed arcing contact assembly suitable for 400 Amp 11KV HT VCB 11 Supply only Moving arcing contact assembly suitable for 400 Amp 11KV HT VCB 12 Supply only Shunt trip coil 24-30 Volts DC suitable for 11KV VCB 13 Supply only Spring charging motor 110-230 Volts AC 50 Hz suitable for 11KV VCB. 14 Supply only PVC spout assembly suitable for 11KV VCB/ Bus coupler 15 M&L for checking tripping of33/11KV circuit breakers through programming microprocessor based numerical relay/ IDMT over current and earth fault relays at plug setting intended in service by primary current injection in CT to ensure proper function of relays trip coil control circuit etc during fault condition complete all as specified and directed. 16 M&L for testing of over current & earth fault of programming microprocessor based numerical relay/ IDMT relays as pertime/currentcharacteristics by secondary injection test O/C 50%,75%, 100%, 200% & E/F20-80% plug setting and operating time at twicethe set valve &TMS 1 including well cleaning and de-carbonizing ofrelay contacts complete all as specified and directed. 17 Supplying, laying, testing and commissioning in repair, XLPE insulated, screened, PVC sheathed galvanised steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor ISI marked 11 KV grade (Earthed system) laid in trenches / on pole / in ducts or through sleeves of size 95 Sqmm 3 core complete all as specified and directed. 18 All as per item 6.0 above but cross sectional area of size 120 Sqmm 3 core 19 All as per item 6.0 above but cross sectional area of size 150 Sqmm 3 core 20 All as per item 6.0 above but cross sectional area of size 185 Sqmm 3 core 21 Material and labour for taking out HT underground cable of any size or type from excavated trenches, repairing the same as required at site and relaying the cable after repair at same or another locationcomplete all as specified and directed..Note (i)- Necessary excavation, earthwork, jointing materials will be measured and paid separately under relevant items of schedule. 22 Dismantling steel tubular poles of any size complete all as specified and directed. 23 Supply and erecting steel tubular swaged pole with cast iron base plate, finial taper plug, bolts, nuts & washers as per IS 2713 (Part-II) 1980 made out of mild steel tubing, type 410 SP-55 (11 metre long) including painting of poles with one coat of red oxide primer and two coat of aluminum paint (one coat before fixing and one coat of aluminum paint after fixing) over exposed surface and two coats of bituminous paint over embedded portion & the portion above coping shall be painted in alternative bands of black and yellow colour starting with white colour (each band of 30cm wide) by two coats of super enameled paint upto 1.5m height complete all as specified and directed. Note : Earth work and PCC shall be measured separately. 24 Excavation in trenches for laying under ground cable, erection of poles and stays in soft soil type not exceeding 1.5 meter wide and not exceeding 1.5 meter deep and getting out in soft / loose soil complete all as specified and directed. 25 Excavation in trenches for laying under ground cable, in PCC /Floor/Road/path etc not exceeding 1.5 meter wide and not exceeding 1.5 meter deep and getting out in hard / dense soilcomplete all as specified and directed. 26 Excavation in soft /loose soil in trenches not exceeding 1.5 mtr wide and exceeding 1.5 mtr in depth but not exceeding 3.0 mtr in depth and getting outgetting out in soft / loose soil complete all as specified and directed. 27 Returning, filling in including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified and directed. 28 Removing surplus excavated material to a distance not exceeding 50 meter above the starting point complete all as specified and directed. 29 M&L for Sand cushioning to under ground cable in trenches/existing cable trenches/ductsin layers of 8 cm deep before laying the cable and 15 cm deep after laying and stretching the cable complete all as specified and directed.Note :- Measurement shall be taken after gentling puning of sand (i.e 18 cm) 30 Supplying and laying un-reinforced precast concrete cable cover class HV type 1 withsize 300 mm x 180 mm x 40 mm complete all as specified and directed. 31 M&L for PCC 1:4:8 type D-2 using 40mm graded crushed stone aggregate as in foundation filling and mass concrete complete all as specified and directed. 32 M&L for PCC 1:3:6 type C-2 using 40mm gradedcrushed stone aggregate as in foundation complete all as specified and directed. 33 Material & labour for Repair and maintanance of 11 KV HT RMU indoor/outdoor type, each wayof RMU 630 Amp rating,SF6 breaker 5 way (Make:- C&S) from HT Panel after switching off electric supply. Removal of all the possiblemechanical/electrical /control system for proper functioning e.g. spring charge system, triping system,indication system, includingchecking the quality of insulating material, complete & refixing with faulty part replacedblowing out dust and applying the proper lubrication/ greasing and reassembling theincluding motorised operation andconnection to HT panel & filling of gas (if quantity is lesser than required) and make the RMU functional to the entire satisfactionand as directed bytheEngineer-in-charge. Note:- (i) check the leakage of SF6 gas fro RMU andSF6 gas charging will be measured separetely. (ii) Repairing/servicing shall be carried out through O.E.M of manufactures engineering/technician. (iii) Cost of small spare parts like gasket,O ring,nuts,bolts and lubrication/cleaning required for servicing of RMU is deemded to be included in the quotated rate. However cost of the major spare parts will be measured and paid separetaly under relevent items of schA.(iii) Job of repairing/servicing/calibrating/testing/setting of fault tripping and recommissioning has been considered for complete set of RMU as per location. 34 Supply only SF6 gas suitable for HT 11 KV RMU 35 Supply only saver mechanism ON/OFF operating complete with spring, fire stick, tripping coil system etc for RMU 36 Supply only actuator motor for operating mechanism charging motor ON/OFF for RMU and testing 37 Supply only self powered relay CG/14S suitable for RMU 38 Supply & testing of spring charging mechanism with motor for outdoor/indoor type, 11KV, RMU,operated on 230/110/24 voltsDC,with charging time less than 15 sec of approved rating complete all as specified and directed. 39 Material and labour for repairing /servicing of gang operating devices 11000 volts up to 400 Amps including cleaning, greasing all the moving parts and applying petroleum jelly at the contact points including dismantling and replacing all the unserviceable parts/ spares complete all as specified and directed.Note :- (i)The rate quoted against this item shall be deemed to include cost of petroleum jelly, renewal of worn out nuts, bolts & washers, binding wire and PG clamps etc complete as required for proper functioning of GOD switch.(ii)Cost of item required to be repalced for making GOD switch serviceable will be measured and paid under supply only under item No 23.01 & 23.02 here in after. 40 Supply only Moving contact blades copper alloy (Male contact). 41 Supply only Fixed contact jaw copper alloy (Female contact). 42 Dismantling unserviceable cross arms, clamps etc and removing from site complete all as specified and directed. 43 Material and labour for cross arms, bracings, supports, clamps, hooks and back plates fabricated from structural steel sections including nuts, bolts, washers welding, bending cold or hot drilling holes for bolts in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of aluminum paint complete all as specified and directed. 44 Dismantling insulators any type/ size from HT network complete all as specified and directed. 45 Supply and fixing in repair ofpintype insulator suitable for 11 KV, procelain vitreous white, brown or green of size 150 mm height and 150 mm dia, ISI marked including one galvanised steel spindle, two galvanised iron washers and one galvanised iron nut complete all as specified and directed. 46 Supply and fixing in repair of post top insulator of 11 KV grade suitable for air break switch/ drop out fuse assy with necessary nuts, bolts, washers complete all as specified and directed. 47 Supply and fixing in replacement lightning arrestor expulsion type complete with all fittings, transmission class discharge capacity 65 KA, 11000 volts complete all as specified and directed. 48 M&L for repair/ Maint/ servicing of33/11KV/ 400Amp GOD AB switch to made it proper functional by oiling/ greesing of mechanical operating mechanism and renewal of old rusted nuts/ bolts/ MS clamps/ handle and provide jelly between fixed and moving contacts complete all as specified and directed. 49 M&L for replacement of female contact / fixed contact Jaw suitable for 33KV GOD AB switch of rating 400 Amp complete all as specified and directed. 50 M&L for replacement of male contact/ moving contactblade suitable for 33KV GOD AB switch of rating 400 Amp complete all as specified and directed. 51 M&L for replacement of tinned copper flexible jumper suitable for 33KV GOD AB switch of rating 400Amp complete all as specified and directed. 52 M&L for replacement of MS jumper carrier suitable for 33KV GOD AB switch of rating 400Amp complete all as specified and directed. 53 M&L for replacement of back connector plate suitable for 33KV GOD AB switch of rating 400Amp complete all as specified and directed. 54 M&L for replacement of PG clamps suitable for 33KV bus bar over head conductor complete all as specified and directed. 55 Material and labour for insulating mat for electrical installations, ISI marked of IS:15652 and of size 2 mtr x 1 mtr x 20 mm suitable for 11 KV system complete all as specified and directed. 56 Material and labour for HT cable route indicators made out of PCC 1:2:4 type B1 duly rendered with plaster 10 mm thick of size 40 cm x 60 cm x 20 cm fixed & erected on PCC platform of size 40 cm x 40 cm x 10 cm grouted in ground duly painted on both sides with HT cable Route complete all as specified and directed. 57 Supply and fixing in replacement Lead acid battery 12volt 140AH complete all as specified and directed. 58 Supply and fixing in replacement tubular battery 12 volt 150 AH complete all as specified and directed. 59 Fault location of underground HT cable of any size or type with help of cable fault locator machine at site including removal of moisture content from the cable complete all as specified and directed.Note :- The machine for fault location will be arranged by the contractor in the quoted rates. However, necessary excavation, earthwork, jointing materials will be measured and paid separately under relevant items of schedule. 60 Disconnecting and taking down HTcable from HT pole/ transformer and cutting faulty end portion of the cable, dressing properly and making good end termination, outdoor type with and including suitable size of heatshrinkable new jointing kit 11000 volts grade and aluminum lugs duly crimped with crimping tool for the following sizes of HT cables:- 61 95 Sqmm 3 core. 62 120 Sqmm to 185 Sqmm 3 core. 63 Disconnecting and taking down HTcable from HT pole/ transformer/VCB/RMU and cutting faulty end portion of the cable, dressing properly and making good end termination, Indoor type with and including suitable size of heatshrinkable new jointing kit 11000 volts grade and aluminum lugs duly crimped with crimping tool for the following sizes of HT cables:- 64 95 Sqmm 3 core. 65 120 Sqmm to 185 Sqmm 3 core. 66 Supply and jointing HT cable with jointing kit for 11 KV (Earthed) grade cable for straight through heat shrinkable type joint with jointing material and accessories suitable for 3 core XLPE armoured aluminum conductor cable of following sizes of HT cables compele all as specified and directed.Note:- Excavation and earth work shall be measured and paid separetely. 67 95 Sqmm 3 core. 68 120 Sqmm to 185 Sqmm 3 core. 69 M&L for Relaying of Cable cover retrieved from excavation during relaying of cable complete all as specified and directed. 70 Material & labour for GlowSchematic diagram on flex sheet (size approx 150cmx75cm) made up of retroreflective material (blue colour)of schematic diagram and writing the letters/diagram on sign board in white compele all as specified and directed. 71 M&L for painting of steel tubular HT pole 11 mtr including cross arms, clamps, back plates etc in situ with one under coat and one finishing coat of aluminum paint after cleaning/ preparation of surfaces including making yellow and black strips 30 cm wide 5 Nos with two coats of synthetic enamel paint compele all as specified and directed. 72 All as per item No 47 above but for 2 pole structure including bracings. 73 All as per item No 47 above but for 4 pole structure including bracings. 74 Supply and fixing in replacement first aid box containing all first aid medicine/ointment/bandage etc as per standard practicecomplete all as specified and directed. 75 Supply and fixing precautionery/educational Rollup Chart(Electric shock treatment/First aid chart etc) of approx size 95x65cm printed on pvc sheet/photografic paper pipe mounted , thread for wall hanging,water proofcompele all as specified and directed. 76 M&L for copper earthing in replacement with copper earth plate electrode 90 cm X 60 cm X 3.15 mm buried directly in ground (earth pit not less than 3.0 mtr deep beliow ground level) with top edge of the plate not less than 2.25 mtrs below normal ground level,connecting to copper strip 20 X3 mm as earthing strip by means of bolts,nut check nut and washers protected with and including 40 mm dia medium grade GI pipe,necessary excavation and earth work,magnesium sulphate (80 Kg) ),charcoal (2 Qtl) and common salt (2 Qtl) filling,watering arrangement with 20 mm GI pipe medium grade including PCC pit with pre cast RCC (1:2:4) cover ,GI funnel with test point,testing (all as shown in electrical plate No 5 and commissioning compele all as specified and directed. Note:- On testing ,after completion ,if the earth resistance below 1 Ohms is not obtained ,earthing will rejuvenated at no extra cost till the desired earth resistance is obtined. 77 Preparation of old steel surfaces of any description over 10 cm width or girth, not otherwise described and M&L for applying one coats of synthetic enamel paint over a coat of zinc chromate primer compele all as specified and directed. 78 Supply and laying broken stone of gauge 45 mm over installation complete all as specified anddirected. 79 Supplying, installing, testing and commissioning OUT door type HT Bus bar chamber, suitable for 11KV,50 Hz AC Supplymade out of MS sheet of 3.15mm thickness for outer sheet and CPRI approved, factory made in an approved factory having seven tank treatment process for powder coating with thickness not less than 60 microns provided with suitable gasket to make it dust / vermin proofdouble door type including locking arrangement bus bar chamber enclosed completehaving legs 45 cms made out of 65X65X6 mm angle iron grouted on brick masonary plateform upto 30 cms. Brick masonaryplateform should be 60 cms above the ground level comprising the followings:- (a) 60 X10 sqmm sqmm cross section area conductive electrolyte grade copper bus bar of required length with heat shrinkable sleeves,duly colour coded.(b) Bakelite insulators having short circuit with stand capacity of 26.3 kilo Amp-01 (Set of three) Note:- (i) The panel shall be front operated with cable entry from bottom with cable glands. The fault with standing capacity shall be 25 KA. Earth bus shall be part of the main feeder pillar. (ii) Cost for construction of plateform for panel of brick masonary work in CM 1:6 withfoundation PCC 1:4:8 type D-2 including plaster work,PCC copping 1:2:4 (40 mm thick stone aggerate), deemed to be included in the item rate and no extra payment will be made. (iii)Danger Sign Board of 11000 KV should be enclosed on panel with red colour. 80 Dismantling air break gang operated switch vertical/ horizontal mounted including insulators and operating mechanism and removing the same from site compele all as specified and directed. 81 Material and labour for fixing air break gang operated switch outdoor type HT 11 KV triple pole mechanically operated mounted on HT insulators horizontal/ vertical type as existing at site including MS galvanised steel frame with operating mechanism worked from ground level including operating rod of size 32 mm dia GI medium grade for current rating of cap 200 Amps 11000 volts with locking arrangement, MS clamps, bolts, nuts and washers etc including two coats of aluminum paint over a coat of red oxide primer on MS work compele all as specified and directed. 82 Supply and fixing in replacement drop out fuse assy single pole 11 KV, 25 Amps rating complete with expulsion fuse element mounted on four/two pole structures including necessary nuts, bolts and washers compele all as specified and directed. 83 Supply and fixing in replacement battery charger 12/24volt with over charge protection suitable forlead acid battery upto 180AH capacity compele all as specified and directed. 84 S & F Danger Sign Board In Red Colour (Electric ) surface stcker type approx size 15x22cm complete all as specified and directed 85 Supply and fixing in replacement galvanised steel tube, light grade laid along the pole/ in trenches / underroad or floor of size 80 mm bore including removing the rusted old one compele all as specified and directed. 86 Supply and fixing in replacement galvanised steel tube, light grade laid along the pole/ in trenches / underroad or floor of size 100 mm bore including removing the rusted old one compele all as specified and directed. 87 Supply and fixing in replacement of MCCB enclosure metal box as per existing/Sample including bus bar for fixing of 4 pole MCCB of size 63 Amp to 160 Amp in Walls etc complete all as specified and directed. 88 Excavation in post hole (or similar hole) each n exc 0.5 cum,getting out,returning,filling in and ramming earth or broken rubble mixed with earth around,in layers not exceeding 25 cm in soft/loose soil compele all as specified and directed. 89 M&L for providing cement concrete type C2 1:3:6 using 40 mm graded crushed stone aggregate as in foundations,filling and mass concrete compele all as specified and directed. 90 Supply only chain link fencing made out of mild steel galvanised wire of any size all compele all as specified and directed. 91 Fixing only chain link fencing including line wires,any mesh,sizes and type to any type of strandards,rail,straining bolts etc including provision of binding wire complete all as specified and directed.Note:- (i) Supply only fencing will be measured and paid separately. (ii) Supply and fix mild steel nut bolt,line wire and flat will be measured and paid separately. 92 Supply and fix mild steel section finpost and struts for fencing including cutting top to shape as directed drilling hole notching for wire etc or flat iron fillet (for security wire mesh etc) including all necessary drilling bolting or riverting etc complete all as specified and directed. 93 Supply and fixing Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends,each screwed end to be fitted with washers and one hexagonal or square nut, n exc 5 cm long & dia of shank 11 to 15 mm compele all as specified and directed.
Contract Date: Oct 15, 2025 Contract Value : 29.61 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 3
Uttar Pradesh View Result →
27.
Defence #7963199 AOC
Tender For Upgradation Of Electrical Sub Stn Under Ge Nagrota.; 1 Supply, Erection, Testing and Commissioning of 11 KV, 630A, 21KA for 3sec, SF6 insulated chamber with one LBS + 2 VCBs, manual spring charged, outdoor type, Right side extensible RMU type, tested in line with latest IEC standards. The RMU shall be suitable for operations at a height up to 1000 meters above sea level and at 40 degree ambient temperature without any derating. The switchgear and busbar shall all be contained in a stainless steel enclosure filled with SF6 at 0.3 bar (300 hPa) relative pressure. The RMU tank shall provide full insulation, making the switchgear insensitive to the environment with degrees of protection of IP67. The switchgear operating mechanism shall have an IP2X protection and cable chamber shall have IP3X. Over all IP protectionshall be IP55.Accidental overpressure due to an internal arc is limited by the opening of the safety valve, at the bottom of the metal enclosure, away from the operator. An operator situated in front, lateral (A-FLR 21KA – 1sec, downwards exhaust,for tank as well as cable compartment) of the RMU switchboard during an internal fault will not be exposed to the effects of arcing. Internal Arc Type Test Report for IAC AFL R21 KA for 1 sec for both tank & cable box should have been for minimum 3 way / 3 Function RMU. Plug in type of extensibility must be provided and coupling busbar should not be exposed to air to avoid oxidation of busbars. Extension of cubicle should only require 450mm to handle and the gap between the coupled RMU’s must be within 10mm. All operations shall be from front of the RMU, including access to cable bushings. Cable bushings along the sides or the rear of the RMU are not acceptable. 2 11kV, 3 Way Ring Main Units one LBS +2 VCB + Bus metering panel Each of the above Ring Main Unit shall comprise of the followings:(i). Load Break Switch (LBS) (one No each comprising of the following:(a) 11 KV, 630A, 21KA for 3sec manual spring charged mechanism, Load break switch; with built in line side manual earth switch. Earthing should be completed within 2 operations only(i.e 1. Main switch - OFF, 2 Earth switch - ON). LBS shall have 3 positions, open or disconnected, closed & earthed, and will be constructed in such a way that interlocking prevents unauthorized operations. For earth switch, manual opening and closing will be driven by a fast-acting /snap action mechanism, independent of operator action. LBS and earth switch shall have a min of 1000 (M1) mechanical operations and 5 No closing operations at rated SC current. LBS should have 100 electrical operations at rated current -01 No(b) Position indicator through clear front mimic in line with IEC 62271-103 - 01 No(c) Live cable indicator with indications (Voltage Presence Indicator) at the front and three inlets provision to check the synchronization of phases. VPI should be of same make as that of RMU -01 No(d) Cable box with termination bushing suitable for upto 2 RUN 3Cx300 Sq mm, XLPE cable -01 No(e) Fault passage indicator (FPI) with in-built Overcurrent, Short Circuit and earth fault indicationFPI should have external indication. -01 NoFPI should act as communicable ammeter as it shall support sharing load data with FRTU. FPI should be of same make as that of RMU. -01 No(f) Cable Boots suitable for actual cable size -01 No(g) Auxiliary switch : LBS - 2 NO +2 NC, Earth switch - 1 NO + 1 NC -01 No(h) Mechanicaloperation counter -01 No 3 (ii). Vacuum circuit breaker (VCB) (Two No each comprising of the following:(a) 11 KV, 630A,21KA for 3sec manual spring charged VCB with spring assisted mechanism and series trip coil; with built in manual line side three position disconnector cum earth switch.Earthing should be completed within 2 operations only(i.e 1. Main switch - OFF, 2. Earth switch - ON). Vacuum interrupter should be of same make as that of RMU. The circuit breakers shall have 2 positions: open or disconnected and closed. A separate and independent 3 position earthing switch and disconnector shall be fitted to open and earth the cables in such way that interlocks prevent all unauthorized operations. An independent mechanism shall be fitted for the 3 positions earthing switch and disconnector. Circuit breaker shall have a min of 2000 mechanical and 2000 electrical operations at rated current and 50 nos of operations at rated short circuit current. Disconnectorand earthswitch shall have a min of 1000 (M1) mechanical operations. The earthing switch shall be fitted with its own operating mechanism and manual closing shall be driven by a fast-acting mechanism, independent of operator action. 01 No(b) Position indicator through clear front mimic in line with IEC 62271-103 -01 No(c) Self powered relay with O/C , E/F protection. Relay should have a front USB port for laptop interface , LCD display ,10 event records, 5 fault records with time stamp, min 2 setting group and keypad for setting parameters for the relay. Relay should be of same make as that of RMU -01 No(d) Suitable CT ratio **/1 A, Class 1 / 5P10 , 2.5VA for protection.MFM for outgoing breaker with modbus RS485 -01 Set(e) Live cable indicator with indications (Voltage Presence Indicator) at the front and three inlets provision to check the synchronization of phases.VPI should be of same make as that of RMU -01 No(f) Cable box with termination bushing suitable for upto 2 RUN 3Cx300 Sq mm, XLPE cable including suitable touch proof termination kit -01 Set 4 (g) Cable Boots suitable for actual cable size -01 Set(h) Mechanical operation counter -01 No(j) Emergency trip push button -01 No(iii). Air Insulated Bus Connected Unit comprising the following(a) Air Insulated enclosure with necessary bus connection-01 No(b) 11KV/rt3/110V/rt3; 50VA class 0.5. Single phase bus PT for metering -03 No(iv). Accessories(a) Antireflex operating handle -01 No(b) Manometer with remote contact -01 NoNote:- RMU shall be mounted on PCC foundation/platform as per site requirement. The cost of PCC foundation is deemed to be included in the unit rate quoted by the bidder. The PCC platform shall be constructed as directed by GE. 5 Supply,laying, testing and commissioning HT 11 KV Volts grade overhead Arial Bunch Conductor of size 3 core x 95 sqmm + 1 core x 70 sqmm having phase conductor of stranded compacted circular aluminium, Conductor screen of extruded semi conducting compound, XLPE insulated, Insulation screen of semi conducting compound, overall Metalic screen of copper type, extruded PVC type ST2 sheathed, twisted armoured bare aluminium alloy messenger conductor generally as per IS-7098/P-2on steel tubular pole complete all as specified and directed.Note:- All the accessories like hooks, clamps etc; required for hanging of the ABC cable shall be included in the quoted rate by the bidder. 6 Steel tubular swaged pole, type 410 SP-55, 11 metre long, complete with mild steel base plate 6mm thick of size 300mm x 300mm, finial taper plug, bolts, nuts, washers and screws, including drilling of holes of required size and nuts for hanging of cable, painting with two coats of aluminium paint over a coat of red oxideand two coats of black bituminous paint for portion embedded in concrete, painting five black and white bands at lower portion of pole each of 300 mm height at 300mm spacing complete all as specified and directed. 7 Supply, laying, testing and commissioning aluminium conductor, HT,XLPE insulated,PVC inner sheathed, GI strip or wire armoured and overall PVC sheathed ,heavy duty 11000 volts (E) grade in trenches/on surface of wall/ in GI pipe including dressing and clamping the cable with MS Zinc Passivated clamps and fixing suitable thimbles/lugs including cable glands of suitable size etc of cross-sectional area 95 Sqmm, 3 core complete all as specified and directed . 8 Earth work in excavation by mechanical means Hydraulic excavator)/ in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out in any type of soil (the excavated soil) anddisposal of surplus excavated soil, within a lead of 50m complete all as specified and directed. 9 Plain Cement concrete 1:3:6 type D-2 (using 40mm graded crushed stone aggregate), as in foundations, filling and mass concrete, complete all as specified and directed. 10 Cable jointing kitfor 11 KV (earthed) grade cable for outdoor termination heat shrinkable type joint, complete with and including jointing material and accessories suitable for XLPE armoured aluminium cable of size 50 sqmm to 95 sqmm, 3 corewith and including connecting single thimbles etc; complete all as specified and directed. 11 Plain Cement concrete 1:2:4 type B-1 (using 20mm-graded crushed stone aggregate),as in coping and benching including weathering, slightly rounded or chamfered angles and throating including necessary formwork and finishing the exposed surfaces, complete all as specified and directed 12 Earthing complete with galvanized steel earth plate electrode 600mm x 600mm x 6.0mm thick buried directly in ground ( earth pit not less than 2.25 mtr below normal ground level ) with top edge plate not less than 1.5 metre below normal ground level connected to galvanized earth strip of size 32x6mmas earthing lead by means of bolts, nuts, chuck nuts and washers of galvanized iron earth lead with 15 cm thick alternate layers of charcoal dust & common slat including PCC pit in PCC 1:2:4 type B-1, RCC covermade out of cement concrete 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) reinforced with TMT steel bars 8 mm dia @150 mm c/c both ways with suitable handle andangle iron (40 x 40 x 5) mm frame, GI medium grade watering pipe 20 mm bore and funnel with wire mesh, light grade protection pipe 40mm bore up to main board complete all as shown on electrical plate No 3 of MES Sch 2009 (Part-I) and testing on completion complete all as specified and directed. Note: - On testing after completion of earthing, if desired earth resistance is not obtained, the earthing will be re-done by the contractor at his own risk & cost to the entire satisfaction. 13 Dismantling PCC, steel poles/struts, any size complete all as directed. 14 Dismantling cross-arms of M.S. channel or angle sections etc; complete all as directed. 15 Dismantling insulators any type, any size, complete all as directed. 16 Dismantling of ACSR or AAC conductors, complete all as specified and directed. 17 Dismantling stay assembly complete all as directed. 18 Dismantling Gang operating devices any type any size complete all as directed. 19 Dismantling Earthing any type, any size complete all as directed. 20 Dismantling lighting arrestor any type, any size complete all as directed. 21 Deduction to be made from BOQfor Sch A Part -II (Schedule of credit) Amount of Rs. 1,19,000.00 during AOC.Note: Tenderers shall not quote for this schedule.
Contract Date: Sep 17, 2025 Contract Value : 1.79 Crore
Statutory Bodies & Commissions/Committees No of Bidders 14
Jammu And Kashmir View Result →
28.
Defence #7917151 AOC
Tender For Repair/Maint Of God, Lightening Arrester, Vcbs, Ht Cable, Ht Oh Conductor And Allied Works Under Age E/M Of Ge Satwari; 1 Switch air break gang operated triple pole mechanically operated from ground level, mounted on insulators and steel frame (15 insulator type) outdoor type suitable for vertical installation single break provided with locking arrangement consisting of MS channel, HT post top porceleneinsulator with drop out fuses operating Rod 20m dia GI pipe medium grade confirming to IS:1818 of 1972 and current rating 200 Amp and voltage 11 KVcomplete all as specified and as directed. 2 Switch air break gang operated triple pole mechanically operated from ground level, mounted on insulators and steel frame (15 insulator type) outdoor type suitable for vertical installation single break provided with locking arrangement consisting of MS channel, HT post top porceleneinsulator with drop out fuses operating Rod 20m dia GI pipe medium grade confirming to IS:1818 of 1972 and current rating 400 Amp and voltage 11 KVcomplete all as specified and as directed. 3 Replacement of 12 KV lightning arrestor station class 30 KA complete all as specified and as directed. 4 Replacement of 12 KV lightning arrestor station class 65 KA complete all as specified and as directed. 5 Front of HT panels, under GOD etc Rubber mats of size 1mtr x 2mtr x 2.5mm thickness 11 KVcomplete all as specified and as directed. 6 Anti climbing device, spikes type, fabricated out of MS bars (round, square or flat) including nuts, bolts, washers and welding in two halves made to shapeto suit the cross section of the poles, spike welded to flat iron, including on primer coat, one under coat and two finishing coats of silver aluminium paint including preparation of surfacescomplete all as specified and as directed. 7 Pin/post insulator HT 11KV complete with all fittings and size 150mm height, 150mm dia for 11000 volts grade complete all as specified and as directed. 8 Male contact (moving contact blade) as per sample approved by GE suitable for 11 KV 400 Amp rating GOD including cable lead/wires, thimbles and connected itemsetc,complete all as specified and as directed. 9 Female contact as per sample approved by GE(fixed contact jaw) suitable for 11 KV 400 Amp rating GOD including cable lead/wires, thimbles and connected items etc, complete all as specified and as directed. 10 Tinned copper flexible jumper suitable for 11 KV 400 Amp rating GOD, complete all as specified and as directed. 11 Demolition of Cement concrete (unreinforced) in Poles/ four pole/two pole/HT& LT pole/panel/approach path to sub station (below or above ground level) and removing all the demolished material outside cantt areacomplete all as specified and as directed. 12 Danger notice plate of 1.6mm thick MS sheet vitreous enamelled white with letters, figures and conventional skull and bones in signal Red colour and inclusive fixed with MS flat clamps 25x3mm 2 Nos, nuts, bolts for LT 440 volt of size 20x15cmcomplete all as specified and as directed. 13 All as per description ser item No 12 above here-in-before but for HT 11000 Volt 25x20cm in size complete all as specified and as directed. 14 Earthing complete with galvanised steel earth plate 600 x 600 x 6mm buried directly in ground vertically to a depth not less than 2.25 mtr below normal ground level with top edge of the earth plate at a depth not less than 1.5 mtr below ground level connected to and including GI strip 25x4mm by means of nuts, bolts, washers etc made of and connected to test point and earth dolly as all shown in electrical plate No.3 of SSR Part-I 2009 and specified or indicated including excavation and earth work in any type of soil PCC (1:3:6) type C1 in chamber, pre cast RCC slab 50mm thick in cement concrete (1:2:4) type B1, reinforced with welded steel wire fabric or XPM jali (weight not less than 4.00 kg/Sqm with cast iron frame, funnel, with wire mesh, 20mm bore medium grade GI watering pipe, lugs, 15mm bore medium grade GI protection pipe, test point etc complete all as specified and as directed.d. (Length of GI earth strip & Protection pipe is up to 7.5 RM including) Note: - If soil required in earthing shall be provided by contractor without any extra cost.No extra amount shall be given to contractor for extra earthing soil. 15 Earthing complete with galvanised steel earth plate 600 x 600 x 6mm buried directly in ground vertically to a depth not less than 2.25 mtr below normal ground level with top edge of the earth plate at a depth not less than 1.5 mtr below ground level connected to and including GI wireof size 4 mm by means of nuts, bolts, washers etc made of and connected to test point and earth dolly as all shown in electrical plate No.3 of SSR Part-I 2009 and specified or indicated including excavation and earth work in any type of soil PCC (1:3:6) type C1 in chamber, pre cast RCC slab 50mm thick in cement concrete (1:2:4) type B1, reinforced with welded steel wire fabric or XPM jali (weight not less than 4.00 kg/Sqm with cast iron frame, funnel, with wire mesh, 20mm bore medium grade GI watering pipe, lugs, 15mm bore medium grade GI protection pipe, test point etc complete all as specified and as directed. Note: - If soil required in earthing shall be provided by contractor without any extra cost.No extra amount shall be given to contractor for extra earthing soil. 16 GI Strip of size 25 x 4 mm along the wall, floor, ceilingetc complete all as specified and as directed. 17 Pin/post insulator HT 33KV complete with all fittingscomplete all as specified and as directed. 18 Cross Arms, bracings, supports, clamps, Angle etc fabricated from steel including nuts, bolts, washers, welding, bending, drilling holes for bolts in any shape or size as directed inclusive of one primer coat, one under coat and one finishing coat of aluminium paint incl Dismantling complete all as specified and as directed. 19 Chain link MS Galvanised fencing of 4 mm dia wire of size 150 mm x 100 mm cold dip fixed to angle frame and flat iron with suitable nuts and bolts any size or type complete all as specified and as directed. 20 Plain cement concrete 1:4:8 type D-2 using 40mm graded crushed stone aggregate as in foundation of poles etc complete all as specified and as directed. 21 Plain cement concrete 1:2:4 type B-1 using 20mm graded crushed stone aggregate as in coping of poles/Transformer plinth etc including necessary form work complete all as specified and as directed. 22 Surfaceexcavation not exceding 30 cm deep in soil soft/loose andaveraging 15 cm deepand gettingoutgreen vegetation, roots, bushes,etc surrounding of2 / 4 / 6polestructure / substations / Panels complete all as specified and as directed. 23 Rendering 15 mm thick in cement mortar 1:4 on brick wall surface or concrete surface finished even and fair without using extra cement upto any heightcomplete all as specified and as directed. 24 Dismantling concrete poles/ struts, any size complete all as specified and as directed. 25 Dismantling insulators any type, any size complete all as specified and as directed. 26 Errection Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts and screws as specified type 410 SP-55 (11 metres long) complete all as specified and as directed. 27 Excavation in trenches in any type of soil not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth for taking out of unserviceble/laying new LT under ground cable complete all as specified and as directed. 28 Returning filling in, approved soft/loosesoil, including spreading , levelling, watering and well ramming in layers each not exceeding 25cm in soft/loose soil complete all as specified and as directed. 29 Removing excavated material (surplus soil) to a distance not exceeding 50 mtrs and depositing where directed at a level not exc 1.5 m above the starting point all as specified and directed. 30 Aluminium conductor, steel reinforced wisel/fereet for making bus bar on pole streching including taking down complete all as specified and as directed. 31 Servicing of HT 11KV indoor VCB panel and breakers of any make with mechanism comprising of the following:-(a) Decarburizing/cleaning complete 11kV HT Bus bar chamber with electrical connections, complete bus bar from the bus bar chamber , Cleaning with CTs and ensure proper decarburizing up to proper megger value, refixing the same after applying Backtol Red solution to the bus bar insulator and checking all the connections, tightening the nuts, bolts complete including replacement of defective rusted bolts and nuts complete all as specified and as directed.(b) Servicing of spring loaded operating mechanism.(c) Servicing of spring charging motor.(d) Checking and servicing of gearbox, auxiliary switches, spring, limit switch etc complete.(e) Checking and repairing electrical and mechanical operations(f) Lubrication all moving parts with petroleum jelly and cleaning all bushing insulators with CTC (g) Tightening of all mechanical connections of mechanism(h) Proper Tightening all LV connection of VCB.After completion of above items HT 11 KV supply will be restored as per disconnecing order and testing, complete all as specified and as directed. 32 Collecting necessary required data & peak load details from IED of any type/Make from 11kV HT panel , Transformer/Feeder full load details during peak hours. Relay Setting Calculations & Co-Ordination Study. Unit Protection Setting of Transformers. Feeder wise settings has to be furnished & Report with Firm Recommendations to be submitted , Down Stream Power distribution (Complete 11 KV system) overall co-ordinations of time need to be achieved. Disconnecting IED of any type/Make from 11kV HT panel, cleaning the contacts , IED configuration , Calibration & Testing of all the measuring & protection elements at site. Testing of all the trip functions of the relays after final current settings by simulating fault current by CT secondary injection test set , rectification of defects in control wiring for proper tripping of CB during actual system fault conduction through relay & Tripping coil incomplete all as specified and as directed. 33 Unserviceable Spring charging motor for ExistingHT 11 KV VCB Panel as per existing make and modelcomplete all as specified and as directed. 34 Unserviceablebreaker charging spring of Existing HT 11 KV Breaker as per existing make and modelcomplete all as specified and as directed. 35 Unserviceablemaster trip relay for HT 11 kv existing Make Ashida/ABB/Schneiderand L & Tcomplete all as specified and as directed. 36 Unserviceableover current and earth fault relay HT 11 kv as per existing make and modelcomplete all as specified and as directed. 37 UnserviceableLED Indication Lamps HT 11 kv as per existing make and modelcomplete all as specified and as directed. 38 Outdoor type cable end termination jointing kit heat shrinkable complete with all accessories and jointing materials suitable mounting onangle iron for 3 core 240 SqmmXLPE HT cable (kit shall be not older than 3 months from the date of manufacture)complete all as specified and as directed. 39 Outdoor type cable end termination jointing kit heat shrinkable complete with all accessories and jointing materials suitable mounting on channel/angle iron for 3 core 95 SqmmXLPE HT cable (kit shall be not older than 3 months from the date of manufacture)complete all as specified and as directed. 40 Digital Voltmeter for HT 11 KV as per existing make and modelcomplete all as specified and as directed. 41 Disconnecting only HT 11 KV Supply from HT 11 KV VCB panel and restore HT 11 KV supply after repair, servicing of HT panel,complete all as specified and as directed. 42 Preparation of old painted surfaces steel/iron of structure of any description 11 KV Sub Station for 11/0.433 KV incomer line complete (one incoming 4 pole/2 pole structure with cross arms and one way 11 KV line structure with 11 KV structure to complwte) with two coats of aluminium paint including preparation of the existing surface,complete all as specified and as directed. 43 Maintenance of 33 KV indoor control and relay panel andchecking wiring from outdoor VCB to indoor control panel, tightening of loose connections, U/S indicator with holder, thimble and incl replacement of unserviceable wiring/part including testing, calibration and checking of tripping system of 33 KV control panel through all protective relays installed on each C&R panel including testing and adjust/ repair the alarm circuit as per time current characteristics by primary injuction test at 60%, 75%, 100% plug including well cleaning and decarbonizing of relay contacts complete all as specified and as directed. 44 Overhauling and servicing of 33 KV VCBincluding repair and setting of operating mechanism parts, spring charging material mechanism, well cleaning with petrol and CRC-226 andincl replacing unserviceable parts/ accessories, oiling/ greasing of moving parts, dismantling, checking and well cleaning of pole insulator, checking of vaccum, interupters well cleaning mechanism links fibre reinforced plastic frame around the vaccum interupters including routine and periodical testcomplete all as specified and as directed. Note:- Spare parts required to make VCB functional replaced wih SCADA compatible parts/ accessories will be measured and paid separately under respective items. 45 Supply, installation,testing and commisioning in replacement of 33 KV, outdoor PT, Oil cooled 33KV/110 Voltcomplete all as specified and as directed. 46 Supply, installation,testing and commisioning in replacement of 33 KV outdoor CT oil cooled 200/100/5+5 complete all as specified and as directed. 47 Material and labour for spreading of crushed stone aggregate of nominal size not more than 40mm from the bay/yard manually without damaging any equipments, cable or parts of the 33 KV Grid bays, spreading & levelling of finished gravel uniformaly in layers not exceediong 15 cm thickto true surfacecomplete all as specified and as directed. 48 Cutting and removing grass, vegetation bushes etc from inside boundary wall and outsite boundary wall of 33/11 KV Sub Stn, around 33 KV towersand removing all rubbish to a distance not exceeding 50 mcomplete all as specified and as directed. 49 Servicing & RepairstoAir-break switch (isolator) off load, rotating type, 33 KV, 800 Amps to 1250 Amps capacity, with proper alignment of isolator rotatingblades, with fixed contact jaws, arcing horns, applying petrolium jelly to moving mechanism, cleaning and lubricatingto isolator gear box assembly,tightening all nuts, bolts and clamps of jumpers etc, repairing to isolator gear box assembly and making in proper serviceable condition for smooth functioning, testing and commissioningon loadcomplete all as specified and as directed. 50 Male/moving contact/ rotating blade of HDE copper silver platedofAir Brake, off load isolator switch, rotating type, 33 KV, 1250/800 Amps capacitywith all fixing nuts, bolts etccomplete all as specified and as directed. 51 FixedContacts,madeof HDE copper,silver plated, of Air Brake, off load isolator switch, rotating type,33 KV, 1250/800 Amps capacitywith all fixing nuts, bolts etc.complete all as specified and as directed. 52 Terminal pad for Air Brake, off load isolator switch, rotating type, 33 KV, 1250/800 Amps capacity complete all as specified and as directed. 53 Lightining arrester expulsion type ( set of three as per existing make/model/capacity to be fixed on existing structure) complete with all fitting, transmission class, discharge capacity 65 kilo amps suitable for 33000 volts incl taking down old one etccomplete all as specified and as directed. 54 PVC insulated PVC sheathed cable galvanized steel strip or wire armoured electric control cables (Heavy duty) with stranded Copper conductor of size 2.5 sq mm 10 core 1100 Volts gradecomplete all as specified and as directed. 55 All as per description Srl item No. 54 above but 2.5 sqmm 6 core copper conductor complete all as specified and as directed. 56 Vacuum interrupter suitable for1250 amps, 11 KV HT VCB existing sample complete all as specified and as directed. 57 Dry river sand as cable cushioning 15cm thick layer before laying and 8cm thick over cable after laying the cable in trenchcomplete all as specified and as directed..Note :Measurement shall be taken after punning down. 58 Un-reinforced precast concrete cable cover, class HV, type 1, flat size 300mmx 180mm x 40mm complete all as specified and as directed. 59 Supplying, laying, jointing testing and connecting in replacement , XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured,electric power cable (heavy duty) with multistranded aluminum conductors, 11 KV (E)grade, of size 240 Sq mm, 3 core, laid in trenchescomplete all as specified and as directed. 60 Supplying, laying, jointing testing and connecting in replacement , XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured,electric power cable (heavy duty) with multistranded aluminum conductors, 11 KV (E)grade, of size 95 Sq mm, 3 core, laid in trenchescomplete all as specified and as directed. 61 Cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable ofsize 95 Sqmm incl taking down of existingcomplete all as specified and as directed. 62 Cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable ofsize 240 Sqmm incl taking down of existing complete all as specified and as directed.
Contract Date: Sep 08, 2025 Contract Value : 30.89 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 8
Jammu And Kashmir View Result →
29.
Communications and Information Technology  #7889414 AOC
Bids Are invited for Attending Emergency Break Down Of Ht Services - Attending Emergency Break Down Of Ht Services/Mv Panels Such As Indoor/Outdoor Type Transformer Substation, Transformer Interchange, Acb Breakdowns, Ht Kits, Ab Switches, Correction Of Low Pf By Checking Capacitor Panel Etc.,By Identifying The Fault, Isolating/ Rectifying/ Bypass The Fault, Restoration Of Permanent/ Temporary Supply Including Meggering And Checking Of 11Kv Insulators, Ct/Pt, Transformers, Ht Cable And Structure With 5000/2500 Volts Insulation Tester, Cleaning Of Hg Fuse, Arcing Rods, Providing New Hg Fuses Etc., Complete As Reqd. , Reconditioning Of Ht Panel - Reconditioning Of Ht Panel By Spray Paintingincluding Cleaning Of Rust In Busbar And Cable Chambers, Cleaning Of Ht Spouts With Ctc, Providing Heating Processor Remove Moisture,Applying Of 2 Coats Synthetic Enamel Paint In Bus Bar Chamber, Cable Chamber And Out Side Of Total Ht Panel, Providing New Hardware For All Covers, Closing Of Any Extra Holes In Cable Chambers As Reqrd., , Filtration Of Transformer Oil - Filtration Of Transformer Oil For 160/250/315 /400 Kva Indoor/Outdoor Transformer At Site Till The Dielectric Strength Of Oil Reaches To 40 Kv And Holds For 1 Minute Including Such As Removal Of All Suspended Particles Like Dust, Rust, Scales, Colloidal Carbon Oxidation Sludge Etc., Degassing And Dehumidification Of Transformer Oil Under Vacuum. Circulation Of Heated Oil And Filling Of Treated Oil In Transformer Tank. De-Acidification By Evaporation And Absorption Method And Including Transportation Offiltering Machine, Providing Test Certificate Etc., As Required. , Arresting Of Transformer Oil Leakage - Arresting Of Transformer Oil Leakage From Lt Side Of 160/250 Kva Transformer Including Disconnection Of Htjumpers, Removing Of 2 Nos Lt Cables, Removing Of Top Cover Of Transformer, Replacing Of 6 Mm Thick Gaskets And Oil Seals At 16Mm Brass Bushings, Refixing The Top Cover And Lt Cables Etc., As Req. , Top Up Of Tran
Contract Date: Ref. Documents Contract Value : 21.13 Lakh
Government Departments No of Bidders 1
30.
Defence #7822859 AOC
Tender For Provision Of Fd Electrification At New Malari Under Ge 871; Supplying, design, loading, unloading, installing, testing and commissioning indoor type floor mountedstep down transformer 11000/433 volts (at no load) capacity 250 KVA, AC 3 phase 50 HZ double copper wound oil immerged naturallycooled with external cooling tube core type delta connected on primary side (HV) and star connected on secondary side (LV) in accordance with vector symbol DYn-11 (Vector group) with neutral brought out on secondry side (LV side) and having tapping at 2.5% interval from -7.5% to + 7.5% on HV side having facility to be changed voltage by means of hand operated off load tap changing gear. The maximum temperature rise should not exceed 50 degree celsius in oil and 55 degree celsius in HV/LV winding from ambiant temp when measured by resistance method after continious full load run in ambient temp of 40 degree celcius. The transformer shall confirm IS : 1180 and latest relavent IS and ECBC marked and shall comprise of the following:-(a) One cable box on HV side (primary side) with 3 Nos porcelain bushing with arcing horn suitable for 11 KV complete with bushing copper rods, nuts and washers.(b) One cable box on LT side (secondry side) consisting of four nos percelain bushing with copper rods, complete with nuts and washers with two nos cables glands, suitable for incoming/outgoing of 3 1/2 core 630 Sqmm LT 1100 volt grade XLPE insulated & PVC Sheathed armoured heavy duty cable including glands, joint and jointing materials complete.(c) Oil conservator with filter type drain valve and oil level indicator gauge.(d) De-hydrating breather (TRANSPARENT TYPE) with first fill dehyrating agent (silica gel)(e) Explosive vent.(f) Thermometer pocket with temperature indicator on tank cover.(g) Two earthing terminals on tank cover to facilitate fixing of 32x6mm galvanised iron earth strip for earthing of neutral & body. 2 (h) Rating plate and terminal marking plate.(i) Oil drain filter valve.(j) Lifting lugs.(k) Oil filling hole with cap/plug with connecting plate complete.(l) Air release valve.(m) Four plain solid cost steel detachable rollers.(n) Extra bushing for neutral, outside the LT cable box for providing independent earthing for neutral.(o) First filling of new and unused transformer oilIS-335/93 (fourth revision) marked filtered and tested for not less than 50 KV dielectricstrength at 2.5 mm air gap between testing electrodes.(p) Brick work foundation suitable for 250 KVA Step down transformer,having 100 mm PCC on top type C1 (1:3:6) at top and PCC B2 (1:4:8) at bottom complete all as directed at site.Note :-(i) Certificate of dielectric strength will be provided by contractor after initial filling of oil. 3 Excavation in trenches not exceeding 1.5 m wide and exceeding 1.5 min depthfor , erection of poles and not exceeding 3 m in depth and getting out in hard/dense soil complete all as specified and directed. 4 Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 min depthfor laying of cables, erection of poles, struts/stays, leveling of yard etc not exceeding 10 Sqm on plan and not exceeding 1.5 m in depth and getting out in hard/dense soil complete all as specified and directed.. 5 Material and labour for sand cushioning to underground cable screened un-washed river sand and punning for cushioning to cable complete all as specified and directed. 6 M&L sub-class B bricks, well burnt, laid breadth wise along the length for cable laid in trenches over sand cushion laid for UG Cable protection, complete all as specified and as directed. 7 Returning, filling in, including spreading, levelling watering and well ramming in layers n.exc 25 cm in soft/loose soil complete all as specified and directed. 8 Removing of excavated soilnot exc. 50 M and depositing where directed at a level n. exc 1.5 M above the startingpoints complete all as specified and directed. 9 Material and labour for Plain Cement concrete (1:3:6) type C -2 using 40 mm graded stone aggregate for foundation of poleplateform of transformeretc complete all as specified and directed. 10 Material and labour for Plain Cement concrete (1:4:8) type B-2using 40 mm graded stone aggregatefor bed of poles, complete all as specified and directed. 11 Material and labour Cement concrete (1:2:4) type C -1 using 20 mm graded stone aggregatefor pedestal of poles/copping including necessary frame work ,fair finishing to exposed surfaces using extra cement complete form, complete all as specified and directed. 12 Supply and fix Voltage stabilizer for automatic operation, three phase, naturally oil cooled, Outdoor type & designed for input variation between 300 V to 480 V with output voltage stabilized at 415 with accuracy ± 2.5% and speed of correction 8 Volts per second and of capacity 250 KVA including following.(i) By Pass facilitry in case of emergency (ii) Auto mannual selector switch(iii) Push button switch markedraise and down to control output voltage .(iv) screw driver adjustment to set the voltage to exact specified level.(v) Voltage meter with six way selector switch to indicate either input or output voltage.(vi) first fill of oil with oil level indicator.(vii) Lifting hook and moving wheel. 13 Supply and fix switch air break gang operated triple pole mechanically operated mounted on HT insulator (12 insulators),Non ferrous knife & steelframe with operating mechanism including spring loaded mechanismset of three working from ground level ,consisting of GI pipe of adequate length including locking arrangement with godrej lock of current rating 200 amps for 11000 volts complete all as specified and directed. 14 Supply and lay in trenches or passing through pipe/fixed to wall/pole and duct cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cable (heavy duty) 1100 Volt grade ISI marked confirming to IS 7098 Pt-I with stranded aluminium conductor of size 6 Sq mm 2 Core complete all as specified and directed. 15 Supply and lay in trenches or passing through pipe/fixed to wall/pole and duct cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cable (heavy duty) 1100 Volt grade ISI marked confirming to IS 7098 Pt-I with stranded aluminium conductor of size 10 Sq mm 2 Core complete all as specified and directed. 16 Supply and lay in trenches or passing through pipe/fixed to wall/pole and duct cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cable (heavy duty) 1100 Volt grade ISI marked confirming to IS 7098 Pt-I with stranded aluminium conductor of size 16 Sq mm 2 Core complete all as specified and directed. 17 Supply and lay in trenches or passing through pipe/fixed to wall/pole and duct cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cable (heavy duty) 1100 Volt grade ISI marked confirming to IS 7098 Pt-I with stranded aluminium conductor of size 25 Sq mm 3.5 Core complete all as specified and directed. 18 Supply and lay in trenches or passing through pipe/fixed to wall/pole and duct cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cable (heavy duty) 1100 Volt grade ISI Marked confirming to IS 7098 part-I with stranded aluminium conductor of size 35 Sq mm 3.5 Core complete all as specified and directed. 19 Supply and lay in trenches or passing through pipe/fixed to wall/pole and duct cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cable (heavy duty) 1100 Volt grade ISI marked confirming to IS 7098 pat-I with stranded aluminium conductor of size 50 Sq mm 3.5 Core complete all as specified and directed. 20 Supply and lay in trenches or passing through pipe/fixed to wall/pole and duct cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cable (heavy duty) 1100 Volt grade ISI marked confirming to IS 7098 pat-I with stranded aluminium conductor of size 70 Sq mm 3.5 Core complete all as specified and directed. 21 Supply and lay in trenches or passing through pipe/fixed to wall/pole and duct cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cable (heavy duty) 1100 Volt grade ISI marked confirming to IS 7098 pat-I with stranded aluminium conductor of size 185 Sq mm 3.5 Core complete all as specified and directed. 22 Supply and lay in trenches or passing through pipe/fixed to wall/pole and duct cable XLPE insulated screened triple enameled PVC bedded,screened with earthedsemi conducting compound in combination with copper tape,inner sheath or pvc tapegalvanized steel strip or wire armoured, confirming to IS-7098 part-II electric power cable (heavy duty) 11000 Volts grade with stranded aluminium conductor of size 95 Sq mm 3 Core complete all as specified and directed. 23 Material and labour for galvanised steel tubing light gradeof size 40 mm NB for protection of cable/earth continuity conductor fixed to poles/walls/roof or laid in floors, road crossing/in ducts fixed with clamps, bolts, nuts and washers etc complete all as specified and directed. 24 Material and labour for galvanised steel tubing light gradeof size 50 mm NB for protection of cable/earth continuity conductor fixed to poles/walls/roof or laid in floors, road crossing/in ducts fixed with clamps, bolts, nuts and washers etc complete all as specified and directed. 25 Material and labour for galvanised steel tubing light gradeof size 80 mm NB for protection of cable/earth continuity conductor fixed to poles/walls/roof or laid in floors, road crossing/in ducts fixed with clamps, bolts, nuts and washers etc complete all as specified and directed. 26 Supply and fix cable jointing kit for 11KV (earthed) grade cable for outdoortermination heatshrink type with jointing material and accessories suitable for 3 core XLPE armoured Al conductor of size 95 Sqmm connecting and testing complete all as specified and directed. 27 Supply and fixing of Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts and screws as specified type 410 SP-55 (11.0 metres long) complete all as specified and directed. 28 Material and labour for steel structure, cross arms bracing supports ,clamps, back plates of any type, section incl. nuts, bolts, washers, welding ,bending cold or hot in any size and shape all as directed Includingtwo coats of aluminiumpaints over a coat of red oxide primerincl preparation of surface all complete all as specified and directed. 29 M&L for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required of size 32x6 mm galvanised iron strip complete all as specified and directed. 30 M&L for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required of size 20x3 mm copper strip complete all as specified and directed. 31 M&L for Anti climbing device, Spikes type fabricated out of MS Bars(round/Squre) or flat including nuts,bolts washers,welding in halves made to shape to suit the cross section of the poles clamped and properly secured complete all as specified and directed. 32 S & F Danger Notice Board of 1.6 mm thick mild steel sheet, vitreous enamelled white,with letters, figures and conventional skull and bones in signal red colour incl name of Feeder and fixed with MS clamp bolts and nuts of approved size, for HT 25 x 20 cm size complete all as specified and directed. 33 M&L for earthing in replacement complete with Copperearth plate electrode 600 x 600 x 3.15mm thick directly burried in the ground (Earth pit not less than 2.25 m deep below ground level) with top edge of earth plate not less than 1.50M below the normal ground level, Copper strip of size 20x3mmfrom earth plate/ electrode to test point (upto max distance of 7.50M is included in unit rate) and connected to earth plate & earth test point by means of bolts, nuts, check nuts andwashers of galvanised iron or steel, 15mm bore GI pipe light grade including necessary fittings for protection of earthing wire, watering pipe 20mm bore GI medium grade, concrete chamber in PCC (1:4:8) type D-2 using 40 mm grade aggregate, coping shall be in PCC (1:3:6) type C-1 using 20 mm grade aggregate and internal surfaces of concrete chamber shall be renderd 12mm thick plaster in CM (1:4), funnel with wire mesh of 22 gauge (0.63 mm) 8 mesh per linear incl 50mm thick cover of RCC (1:2:4) type B-1 using 20mm grade stone aggregate reinforced with 8mm MS deformed bar @ 75 mm C/C both ways, char coal dust and common salt all as shown in electrical plate No. 3 of SSR Part-I (2009) includingall necessary excavation & earth work and removal of surplus soil to a distance n. exc 50M andconnection from DB to earth electrode with same GI wire alongwith protection pipe and testing on completion complete all as specified and directed. 34 M&L for earthing in replacement complete with galvansided steel earth plate electrode 600 x 600 x 6.0mm thick directly burried in the ground (Earth pit not less than 2.25 m deep below ground level) with top edge of earth plate not less than 1.50M below the normal ground level, GI wire 4.0mm dia from earth plate/ electrode to test point (upto max distance of 7.50M is included in unit rate) and connected to earth plate & earth test point by means of bolts, nuts, check nuts andwashers of galvanised iron or steel, 15mm bore GI pipe light grade including necessary fittings for protection of earthing wire, watering pipe 20mm bore GI medium grade, concrete chamber in PCC (1:4:8) type D-2 using 40 mm grade aggregate, coping shall be in PCC (1:3:6) type C-1 using 20 mm grade aggregate and internal surfaces of concrete chamber shall be renderd 12mm thick plaster in CM (1:4), funnel with wire mesh of 22 gauge (0.63 mm) 8 mesh per linear incl 50mm thick cover of RCC (1:2:4) type B-1 using 20mm grade stone aggregate reinforced with 8mm MS deformed bar @ 75 mm C/C both ways, char coal dust and common salt all as shown in electrical plate No. 3 of SSR Part-I (2009) includingall necessary excavation & earth work and removal of surplus soil to a distance n. exc 50M andconnection from DB to earth electrode with same GI wire alongwith protection pipe and testing on completion complete all as specified and directed. 35 M&L for earthing in replacement complete with Galvanised iron earth plate electrode 600 x 600 x 6mm thick directly burried in the ground (Earth pit not less than 2.25 m deep below ground level) with top edge of earth plate not less than 1.50M below the normal ground level, GI strip of size 32x6mmfrom earth plate/ electrode to test point (upto max distance of 7.50M is included in unit rate) and connected to earth plate & earth test point by means of bolts, nuts, check nuts andwashers of galvanised iron or steel, 15mm bore GI pipe light grade including necessary fittings for protection of earthing wire, watering pipe 20mm bore GI medium grade, concrete chamber in PCC (1:4:8) type D-2 using 40 mm grade aggregate, coping shall be in PCC (1:3:6) type C-1 using 20 mm grade aggregate and internal surfaces of concrete chamber shall be renderd 12mm thick plaster in CM (1:4), funnel with wire mesh of 22 gauge (0.63 mm) 8 mesh per linear incl 50mm thick cover of RCC (1:2:4) type B-1 using 20mm grade stone aggregate reinforced with 8mm MS deformed bar @ 75 mm C/C both ways, char coal dust and common salt all as shown in electrical plate No. 3 of SSR Part-I (2009) includingall necessary excavation & earth work and removal of surplus soil to a distance n. exc 50M andconnection from DB to earth electrode with same GI wire alongwith protection pipe and testing on completion complete all as specified and directed. 36 Supply,install,testing and commissioning of LT Panel board of to accomodate under mentioned items, CPRI approvedoutdoor type, floor mounted, factory made suitable for 415 volt, 3 PH, 4 wire, 50 HZ, AC supply system having bus bars chamber with copperbus bars duly insulated by insulation of RYB colour 630 Amps rating mounted on porcelain insulators .The panels shall be factorymade, double door, made out of 3.15 mm thick MS sheettotally enclosed dust, vermin and rust prooffront operated, front and rear opening with locking arrangement fixed with MSangle iron frame of size 50X50X5 mm duly embedded in PCC platform and duly powder coated with 7 tank process with colour as directed including internal wiring with multistranded copper conductor cable of suitable sizeincllugs and cable gland to incoming and outgoing cable all as directed at site and comprising of the following:Note : Bottom portion of the panel should be at minimum height of .75 Mtr from the ground level.(i) MCCB 4 pole 400 Amps 50 kA - 01 Nos(ii) MCCB 4 pole 160 Amps 25 kA - 05 Nos(iii) MCCB 4 pole 100 Amps 25 kA - 01Nos (iv) MCCB 4 pole 63 Amps 25 kA - 02Nos (v) MCB TP - 32 Amp -01 Nos(vi) Digital timer switch -01 Nos (vii) Multifunctional VAF meter, PF meter - 1 No (viii) RYB Neon indicating lamp -1 set for each outgoing and incoming (ix) MS work incl angle iron frame and PCC work Space for mounting of additional MCB In future. 37 Supply,install,testing and commissioning of LT Panel board of to accomodate under mentioned items ,CPRI approved ,outdoor type, floor mounted, factory made suitable for 415 volt, 3 PH, 4 wire, 50 HZ, AC supply systemhaving bus bars chamber with aluminium bus bars duly insulated by insulation of RYB colour 200 Amps rating mounted on porcelain insulators .The panels shall be factorymade, double door, made out of 3.15 mm thick MS sheettotally enclosed dust, vermin and rust prooffront operated, front and rear opening with locking arrangement fixed with MSangle iron frame of size 50X50X5 mm duly embedded in PCC platform and duly powder coated with 7 tank process with colour as directed including internal wiring with multistranded copper conductor cable of suitable sizeincllugs and cable gland to incoming and outgoing cable all as directed at site and comprising of the following:Note : Bottom portion of the panel should be at minimum height of 0.75 Mtr from the ground level.(i) MCCB 4 pole 63 Amps 25 kA - 01 Nos(ii) MCB 2 pole 25Amps 10 kA - 12 Nos (iii) Multifunctional VAF meter, PF meter - 1 No (iv) RYB Neon indicating lamp -1 set (v) MS work incl angle iron frame and PCC work(vi) Space for mounting of additional MCB In future.(vii) Internal wiring including copper lugs 38 Supply,install,testing and commissioning of LT Panel board of to accomodate under mentioned items, CPRI approved outdoor type, floor mounted, factory made suitable for 415 volt, 3 PH, 4 wire, 50 HZ, AC supply system having bus bars chamber with aluminium bus bars duly insulated by insulation of RYB colour 200 Amps rating mounted on porcelain insulators .The panels shall be factorymade, double door, made out of 3.15 mm thick MS sheettotally enclosed dust, vermin and rust prooffront operated, front and rear opening with locking arrangement fixed with MSangle iron frame of size 50X50X5 mm duly embedded in PCC platform and duly powder coated with 7 tank process with colour as directed including internal wiring with multistranded copper conductor cable of suitable sizeincllugs and cable gland to incoming and outgoing cable all as directed at site and comprising of the following:Note : Bottom portion of the panel should be at minimum height of 0.75 Mtr from the ground level.(i) MCCB 4 pole 63 Amps 16 kA - 01Nos (ii) MCB 2 pole 32Amps 10 kA - 04 Nos (iii) MCB 2 pole 25Amps 10 kA - 01 Nos (iv) Multifunctional VAF meter, PF meter - 1 No (v) RYB Neon indicating lamp -1 set for each outgoing and incoming (vi) MS work incl angle iron frame and PCC work(vii) Space for mounting of additional MCB In future.(viii) Internal wiring including copper lugs 39 Supply,install,testing and commissioning of LT Panel board of to accomodate under mentioned items, CPRI Approved outdoor type, floor mounted, factory made suitable for 415 volt, 3 PH, 4 wire, 50 HZ, AC supply system having bus bars chamber with aluminium bus bars duly insulated by insulation of RYB colour 200 Amps rating mounted on porcelain insulators .The panels shall be factorymade, double door, made out of 3.15 mm thick MS sheettotally enclosed dust, vermin and rust prooffront operated, front and rear opening with locking arrangement fixed with MSangle iron frame of size 50X50X5 mm duly embedded in PCC platform and duly powder coated with 7 tank process with colour as directed including internal wiring with multistranded copper conductor cable of suitable sizeincllugs and cable gland to incoming and outgoing cable all as directed at site and comprising of the following:Note : Bottom portion of the panel should be at minimum height of 0.75 Mtr from the ground level.(i) MCCB 4 pole 100 Amps 25 kA - 01 Nos(ii) MCB 2 pole 25Amps 10 kA - 04 Nos (iii) MCB 2 pole 20Amps 10 kA - 2 Nos (iv) MCCB 4 pole 63Amps 10 kA - 01 Nos (v) Multifunctional VAF meter, PF meter - 1 No (vi) RYB Neon indicating lamp -1 set for each outgoing and incoming (vii) MS work incl angle iron frame and PCC work(viii) Space for mounting of additional MCB In future.(ix) Internal wiring including copper lugs 40 Supply,install,testing and commissioning of Bus bar chamber of to accomodate under mentioned items,CPRI approved outdoor type, floor mounted, factory made suitable for 415 volt, 3 PH, 4 wire, 50 HZ, AC supply system having bus bars chamber with aluminium bus bars duly insulated by insulation of RYB colour 200 Amps rating mounted on porcelain insulators having outgoin min 06 Nos.The panels shall be factorymade, double door, made out of 3.15 mm thick MS sheettotally enclosed dust, vermin and rust prooffront operated, front and rear opening with locking arrangement fixed with MSangle iron frame of size 50X50X5 mm duly embedded in PCC platform and duly powder coated with 7 tank process with colour as directed including internal wiring with multistranded copper conductor cable of suitable sizeincllugs and cable gland to incoming and outgoing cable all as directed at site and comprising of the following:Note : Bottom portion of the panel should be at minimum height of 0.75 Mtr from the ground level.(i) MCCB 4 pole 63 Amps 16 kA - 01 Nos(ii) Aluminium bus bar with provision of 06 nos of outgoing separately for RYB and N (iii) Multifunctional VAF meter, PF meter - 1 No (iv) RYB Neon indicating lamp -1 set for each outgoing and incoming (v) MS work incl angle iron frame and PCC work(vi) Space for mounting of additional MCB In future.(vii) Internal wiring including copper lugs 41 Supply,install,testing and commissioning of LT Panel board ofto accomodate under mentioned items,CPRI approved outdoor type, floor mounted, factory made suitable for 415 volt, 3 PH, 4 wire, 50 HZ, AC supply system having bus bars chamber with aluminium bus bars duly insulated by insulation of RYB colour 400 Amps rating mounted on porcelain insulators .The panels shall be factorymade, double door, made out of 3.15 mm thick MS sheettotally enclosed dust, vermin and rust prooffront operated, front and rear opening with locking arrangement fixed with MSangle iron frame of size 50X50X5 mm duly embedded in PCC platform and duly powder coated with 7 tank process with colour as directed including internal wiring with multistranded copper conductor cable of suitable sizeincllugs and cable gland to incoming and outgoing cable all as directed at site and comprising of the following:Note : Bottom portion of the panel should be at minimum height of 0.75 Mtr from the ground level.(i) MCCB 4 pole 160 Amps 25 kA - 01 Nos(ii) MCCB 4 pole 63 Amps 25 kA - 02 Nos(iii) MCCB 4 pole 32Amps 10 kA - 02 Nos(iv) MCCB 4 pole 63Amps 16 kA - 01 Nos (v) On load change over switch of capacity 160 amp 4P-01 nos (vi) Multifunctional VAF meter, PF meter - 1 No (vii)RYB Neon indicating lamp -1 set for each outgoing and incoming (viii) MS work incl angle iron frame and PCC work(ix)Space for mounting of additional MCB In future.(x)Internal wiring including copper lugs 42 S&F HT lightening arrestor expulson type complete with all fittings transmission class discharge capacity 65 kilo amp suitable for 11 kv complete all as specified and directed. 43 Supply and fix Pin type porcelain vitreous whiteinsulator 11000 volt grade 150 mm in height and 150 mm dia including galvanised mild steel strap of size 31x3mm , 12 mm dia insulators bolts, washers and nuts complete all as specified. 44 Supply and fix disctype insulator , vitreous porcelain whitebrown or green , over all dimension 140 mm high 240 mm dia and clearance of hole 25.5 mm complete all as specified. 45 Material and labour forACSR conductor straightening properlyon insulators and binding with aluminum taps /binding wire /conductor jumper etc complete ofsize 6/1x2.59mm (Weasel) .
Contract Date: Aug 18, 2025 Contract Value : 47.35 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 2
Uttar Pradesh View Result →
Uttar Pradesh View Result →
34.
Banking and Finance #7766667 AOC
Tender For Upgradation Work At Industrial Area Rangwasa, Dist. Indore - Construction of 12 Meter wide CC road - Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300mm, removel of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned up to a lead of 1000 metres including removel and disposal of top organic soil not exceeding 150 mm in thickness if required and as per relevant clauses of section-200 (B) In area of Light jungle For 12 mtr wde road Hectare 0.47 22,918.00 3.3 Excavation for roadwork in soil with hydraulic excavator including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross sections, and transporting to the embankment location with all lifts and lead upto 1000m as per relevent clauses of section-300 of specification. Road i/c Footpath CuM 1872.00 55.00 3.4 Excavation in Ordinary Rock using Hydraulic Excavator and Tippers with disposal upto 1000 metres.Excavation for roadway in ordinary rock with hydraulic excavator including cutting and loading in tippers, transporting to embankment site with in all lifts and lead upto 1000 m, trimming bottom and side slopes in accordance with requirements of lines, grades and cross sections as per relevent clauses of section-300 of specification CuM 1872.00 75.00 3.5 Excavation in Hard Rock with disposal upto 1000 metres Excavation for roadway in hard rock with rock breakers i/c breaking rock or by drilling, blasting and breaking, trimming of bottom and side slopes in accordance with requirements of lines, grades and cross sections, loading and disposal of cut road with all lifts and leads upto 1000 metres and as per relevent clauses of section-300 of specification. CuM 1404.00 203.00 3.13 Embankment Construction with Material Obtained from Borrow Pits Construction of embankment with approved material having CBR>7 obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacting to meet requirement of table 300-1, 300-2 and as per relevent clauses of section300. Embankment/ Sub grade CuM 2340.00 2340.00 155 4.12 Crusher Run Macadam Sub Base/Base Course Providing crushed stone aggregate, depositing on a prepared surface by hauling vehicles, spreading and mixing with a motor grader, watering and compacting with a vibratory roller to clause 410 to form a layer of subbase/Base in accordance to Table No. 400-14, 400-15 and as per clause of section 407 of specifications. (i) For 53 mm maximum size Carriageway CuM 386.10 1,145.00 6.1 Dry lean cement concrete Sub-base Construction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 150 kg/ cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant, transported to site, laid with a paver with electronic sensor, compacting with 8-10 tonnes vibratory roller, finishing and curing as per clause 601 of specification complete in all respect. NAME OF WORK : UPGRADATION WORK OF I/A RANGWASA , INDORE BILL OF QUANTITIES Construction of 12 Meter wide CC road 1 2 3 Sr. No. MP PWD Road & Bridge SOR 2022, MPPWD Building Description of Item Unit Qty Rate 5 6 7 4 Road 12M ROW Sr. No. MP PWD Road & Bridge SOR 2022, MPPWD Building Description of Item Unit Qty Rate Carriageway Cum 234.00 2,767.00 6.3 Cement Concrete Pavement Construction of un-reinforced, dowel jointed, plain cement concrete pavement M-40 grade concrete over a prepared sub base with cement, coarse and fine aggregate conforming to IS 383, maximum size of coarse aggregate not exceeding 25 mm, mixed in a batching and mixing plant as per approved mix design, transported to site, laid with a fixed form or slip form paver, spread, compacted and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separation membrane, sealant primer, joint sealant, debonding strip, admixtures as approved,curing compound, finishing to lines and grades as per drawing as per IRC 15 2011 and as per relevant clauses of section 602 of specifications complete but excluding cost of steel in dowel bar and tie rods etc. Carriageway Cum 643.50 6,103.00 9 6.8 Add extra in Item No.6.3, 6.4, 6.6 & 6.10 above for the cost of steel in dowel bar and tie rod including craddle, laps etc. complete required as per design. 6.8.1 Mild Steel dowel bars 32mm Dia @ 300 C/c Carriageway MT 5.25 3% extra for junction 0.16 Total MT 5.40 63587.00 6.8.2 Tie Bar 12 mm Dia @ 600 C/c Carriageway MT 0.37 Total MT 0.37 68297.00 8.25 Road Marking with Hot Applied Thermoplastic Compound with Reflectorising Glass Beeds on Concrete surface. Providing and applying (Cleaning of concrete surface and after applying Concrete primer) thermoplastic compound having composition of binder (Regin) minimum 18 %, titanium dioxide minimum 10 % and intermixed glass beed, minimum 30% of brand like Asian, Burger or equivalent make of 2.5 mm thick including drop down reflectorizing, glass beeds @ 250 gms per sqm area thickness of 2.5 mm is exclusive of surface applied glass beeds as per IRC:35 along with concrete primer. The finished surface to be level, uniform and free from streaks and holes, all complete as per clause 803 of specifications. Note:- The guarantee of Thermoplastic should be minimum 3 Years. sqm 97.50 636.00 11 8.19 Supplying and installation road delineators (road way indicators). as per MORT&H Clause 806. The structure shall be made in roll forming process having height of 80-100 cm above the ground level, width not less than 100 mm and shall extend not more than 300mm below the ground while being installed, buried or pressed in to the ground in confirmation with IRC:79: 1981, are as directed by the by. the Engineer painted black with powder coat of minimum 40 microns thickness for protection against corrosion, on top of which Type XI retro reflective sheeting shall be pasted on both sides complying to IRC:79:1981. The delineator should consist of minimum retro reflective unit exposed area of 330 cm2 white color, full cube corner micro prismatic non-metallic retro reflective sheeting on each side conforming with IRC 67:2012 and meeting the coefficient of retro reflection values as per ASTM D 4956 Type XI label specification. The delineator shall have grooves across thelength to make the reflective sheets vandal- proof. each 5.00 990.00 7 8 9a 9b 10 Road 12M ROW Sr. No. MP PWD Road & Bridge SOR 2022, MPPWD Building Description of Item Unit Qty Rate 8.30 Retro- reflectorised Traffic signs Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign board as per IRC 67-2012 made of high intensity Micro-Prismatic Grade Sheeting (Type IV) vide IRC: 67:2012 clause 6.7.3.2 and clause 801.3.3 of MoRT &H fixed over Aluminum composite material sheet with thermoplastic core of Low density polyethylene (LDPE) between two thick skins/sheets of aluminum with overall thickness of 4mm and aluminum skin of thickness 0.3 on both side, the ACM shall conform to Table 6.1 of IRC:67:2012 and Table 800-1 of MoRT &H specification and High Intensity Micro Prismatic Grade Sheeting shall conform to Table 6.6 of IRC:67:2012 and Table 800-3 of MoRT &H specification of in the clause IRC 6.8 of the IRC 67-2012 and clause 801.3.7 of MORTH message legend numerical letter etc. and borders shall be screen printed on high intensity micro prismatic sheeting shall conform to clause 801.3.7 with digital printing ink or of cutout from transparent durable overlay or cutout from the same type of reflecting sheeting for cautionary/ mandatory/ signs, supported on MS sign post of size 75mm x75mm x 6mm of 3.60 meter over all length and fix to ground by means of properly designed foundation of dimension 450x450x600mm with M20 grade concrete. The ACM sheet shall be fixed to the post with four minimum four number breakaway bolts. & supported with a back support frame of 25mmx25mmx3mm angle. 7 years warranty for Retro Reflection Sheeting to be provided from the original sheeting manufacture as per clause 6.9 of IRC: 67:2012 & a certified copy for three years for outdoor exposure report from an independent test lab as per clause 6.7 of IRC: 67:2012 for the product offered shall be submitted by the contractor.Note:- Manufacture name and date of manufacture is to be printed (Embossed) at the backside of the board. i) 90 cm equilateral triangle each 2.00 4,184.00 13 8.7 Direction and Place Identification signs upto 0.9 sqm size board. Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign board as per IRC 67-2012 made of high intensity Micro-Prismatic Grade Sheeting (Type IV) vide IRC: 67:2012 clause 6.7.3.2 and clause 801.3.3 of MoRT&H fixed over Aluminum composite material sheet with thermoplastic core of Low density polyethylene (LDPE) between two thick skins/sheets of aluminum with overall thickness of 4mm and aluminum skin of thickness 0.3 on both side, the ACM shall conform to Table 6.1 of IRC:67:2012 and Table 800-1 of MoRT&H specification and High Intensity Micro Prismatic Grade Sheeting shall conform to Table 6.6 of IRC:67:2012 and Table 800-3 of MoRT&H specification of in the clause IRC 6.8 of the IRC 67-2012 and clause 801.3.7 of MORTH message legend numerical letter etc. and borders shall be screen printed on high intensity micro prismatic sheeting shall conform to clause 801.3.7 sqm 1.80 6,479.00 with digital printing ink or of cutout from transparent durable overlay or cutout from the same type of reflecting sheeting for cautionary/ mandatory/ signs, supported on MS sign post of size 75mm x75mm x 6mm of 3.60 meter over all length and fix to ground by means of properly designed foundation of dimension 450x450x600mm with M20 grade concrete. The ACM sheet shall be fixed to the post with four minimum four number breakaway bolts. & supported with a back support frame of 25mm x 25 mm x 3mm angle. 7 years warranty for Retro Reflection Sheeting to be provided from the original sheeting manufacture as per clause 6.9 of IRC: 67:2012 & a certified copy for three years for outdoor exposure report from an independent test lab as per clause 6.7 of IRC: 67:2012 for the product offered shall be submitted by the contractor. Note:- Manufacture name and date of manufacture is to be printed (Embossed) at the backside of the board. 6.15 Providing and laying of a reinforced cement concrete pipe NP4 pipes for service ducts below cement concrete pavement (i) (i) 300 mm dia meter 12.00 713.00 12 14 Bituminous concrete Sr. No. SOR Item No. Particulars Unit Quantity Rate (Rs.) 1 5.2 Providing and applying tack coat with catonic bitumen emulsion using emulsion pressure distributor on the prepared bituminous/granular surface cleaned with mechanical broom and as per relevant clauses of section-503 of specifications ii 0.30 kg per sqm (dry & hungry bituminous surfaces /granular surfaces treated with primer) 1500.00 Sqm 1500.00 16 2 5.6 Bituminous Concrete Providing and laying bituminous concrete using crushed aggregates of specified grading, premixed with bituminous binder @ 5.4 to 5.6 % by weight of total mix of mix and filler, transporting the hot mix to work site, laying with a Electronic Sensor paver finisher with sensor control to the required grade, level and alignment, rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per clause 507 of specification. b Using Drum Mix Plant of appropriate capacity v for Grading-II ( 30-45 mm thickness ) Bitumen Content minimum 5.4% with 60/70 bitumen(VG-30) 60.00 Cum 60.00 9482 3 8.25 Road Marking with Hot Applied Thermoplastic Compound with Reflectorising Glass Beeds on Bituminous surface. Providing and applying (Cleaning of Bituminous surface) thermoplastic compound having composition of binder (Regin) minimum 18 %, titanium dioxide minimum 10 % and intermixed glass beed, minimum 30% of brand like Asian, Burger or equivalent make of 2.5 mm thick including drop down reflectorizing, glass beeds @ 250 gms per sqm area thickness of 2.5 mm is exclusive of surface applied glass beeds as per IRC:35.The finished surface to be level, uniform and free from streaks and holes, all complete as per clause 803 of specifications. Note:- The guarantee of Thermoplastic should be minimum 3 Years. . Edge 50.00 Center 12.50 Sqm 62.50 636 4 8.3P45 Retro- reflectorised Traffic signs Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign board as per IRC 67-2012 made of high intensity MicroPrismatic Grade Sheeting (Type IV) vide IRC: 67:2012 clause 6.7.3.2 and clause 801.3.3 of MoRT &H fixed over Aluminum composite material sheet with thermoplastic core of Low density polyethylene (LDPE) between two thick skins/sheets of aluminum with overall thickness of 4mm and aluminum skin of thickness 0.3 on both side, the ACM shall conform to Table 6.1 of IRC:67:2012 and Table 800-1 of MoRT &H specification and High Intensity Micro Prismatic Grade Sheeting shall conform to Table 6.6 of IRC:67:2012 and Table 800-3 of MoRT &H specification of in the clause IRC 6.8 of the IRC 67-2012 and clause 801.3.7 of MORTH message legend numerical letter etc. and borders shall be screen printed on high intensity micro prismatic sheeting shall conform to clause 801.3.7 with digital printing ink or of cutout from transparent durable overlay or cutout from the same type of reflecting sheeting for cautionary/ mandatory/ signs, supported on MS sign post of size 75mm x75mm x 6mm of 3.60 meter over all length and fix to ground by means of properly designed foundation of dimension 450x450x600mm with M20 grade concrete. The ACM sheet shall be fixed to the post with four minimum four number breakaway bolts. & supported with a back support frame of 25mmx25mmx3mm angle. 7 years warranty for Retro Reflection Sheeting to be provided from the original sheeting manufacture as per clause 6.9 of IRC: 67:2012 & a certified copy for three years for outdoor exposure report from an independent test lab as per clause 6.7 of IRC: 67:2012 for the product offered shall be submitted by the contractor. Note:- Manufacture name and date of manufacture is to be printed (Embossed) at the backside of the board. ii 60 cm equilateral triangle Each 5.00 3011 Bituminous Concrete laying over CC Road MPPWD SOR ROAD & BRIDGE WORKS in force from 25-03-2022 Restoration of 1.2 Meter wide dismantaling of CC road for services Construction of Embankment with Material Deposited from Roadway Cutting Construction of embankment with approved materials CBR>7 deposited at site from roadway cutting and excavation from drain and foundation of other structures graded and compacted to meet requirement of table 300-1, 300-2 and as per relevent clauses of section-300. CuM 450.00 Total 450.00 60 3.13 Embankment Construction with Material Obtained from Borrow Pits Construction of embankment with approved material having CBR>7 obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacting to meet requirement of table 300-1, 300-2 and as per relevent clauses of section-300. Embankment/ Sub grade CuM 0.00 155 4.12 Crusher Run Macadam Sub Base/Base Course Providing crushed stone aggregate, depositing on a prepared surface by hauling vehicles, spreading and mixing with a motor grader, watering and compacting with a vibratory roller to clause 410 to form a layer of sub-base/Base in accordance to Table No. 400-14, 400-15 and as per clause of section 407 of specifications. (i) For 53 mm maximum size Carriageway CuM 30.00 1,145.00 6.1 Dry lean cement concrete Sub-base Construction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 150 kg/ cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant, transported to site, laid with a paver with electronic sensor, compacting with 8-10 tonnes vibratory roller, finishing and curing as per clause 601 of specification complete in all respect. Carriageway Cum 30.00 2,767.00 6.3 Cement Concrete Pavement Construction of un-reinforced, dowel jointed, plain cement concrete pavement M-40 grade concrete over a prepared sub base with cement, coarse and fine aggregate conforming to IS 383, maximum size of coarse aggregate not exceeding 25 mm, mixed in a batching and mixing plant as per approved mix design, transported to site, laid with a fixed form or slip form paver, spread, compacted and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separation membrane, sealant primer, joint sealant, debonding strip, admixtures as approved,curing compound, finishing to lines and grades as per drawing as per IRC 15 2011 and as per relevant clauses of section 602 of specifications complete but excluding cost of steel in dowel bar and tie rods etc. Carriageway Cum 90.00 6,103.00 6 6.8 Add extra in Item No.6.3, 6.4, 6.6 & 6.10 above for the cost of steel in dowel bar and tie rod including craddle, laps etc. complete required as per design. 6.8.1 Mild Steel dowel bars 32mm Dia @300 C/c Total MT 0.89 63587.00 6.8.2 Tie Bar 12 mm Dia @ 600 C/c Total MT 0.42 68297.00 Rate Restoration of 1.2 Meter wide dismantaling of CC road for services Sr. No. MP PWD Road & Bridge SOR 2022 Description of Item Unit Qty 6b 1 2 3 4 5 6a Storm Water Network Sl No PHE SOR2023 Item No PARTICULAR UNIT QUANTITY RATE 1 15.6 Earth work in excavation for foundation, trenches for pipes/ cables, drains or in well excavation etc. by mechanical means/ manual means (exceeding 30cm in depth.) including ramming of bottom, dressing of sides disposal of excavated earth including of all lift and lead upto 50m. Disposed earth to be levelled and neatly dressed. 15.6.1 All kinds of soil. pipe line (450 , 600 mm dia) 1600.00 Brick Masonry Chamber @ 20m c/c(450mm dia pipe) 270.00 cum 1870.00 209.00 2 15.6 Earth work in excavation for foundation, trenches for pipes/ cables, drains or in well excavation etc. by mechanical means/ manual means (exceeding 30cm in depth.) including ramming of bottom, dressing of sides disposal of excavated earth including of all lift and lead upto 50m. Disposed earth to be levelled and neatly dressed. 15.6.3 Ordinary rock or soft rock with or without blasting pipe line (450 , 600 mm dia) 1600.00 Brick Masonry Chamber @ 20m c/c(450mm dia pipe) 270.00 cum 1870.00 270.00 3 15.6 Earth work in excavation for foundation, trenches for pipes/ cables, drains or in well excavation etc. by mechanical means/ manual means (exceeding 30cm in depth.) including ramming of bottom, dressing of sides disposal of excavated earth including of all lift and lead upto 50m. Disposed earth to be levelled and neatly dressed. 15.6.4 Hard rock (requiring blasting) pipe line (450 , 600 mm dia) 800.00 Brick Masonry Chamber @ 20m c/c(450mm dia pipe) 168.75 cum 968.75 491.00 4 15.13 Supplying & filling moorum for pipe bedding or over the pipe (including supply of moorum). pipe line (450 , 600 mm dia) 720.00 cum 720.00 649.00 5 28.3 Providing and Laying non-pressure (NP3) RCC socket & spigot pipes with rubber gasket joint including testing of joints. 28.3.6 pipe line 450 mm dia Mtr 2500.00 2512.00 28.3.7 pipe line 600 mm dia Mtr 2500.00 3297.00 CONSTRUCTION OF STORM WATER NETWORK CONSTRUCTION OF STORM WATER NETWORK 29.7 Constructing Brick Masonry Manhole in Cement Mortar 1 :4 (1 cement : 4 fine sand) R.C.C. top slab 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1cement : 3 fine sand) finished with a floating coat of neat cement and making channels in CC 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) including finishing the channel to shape, curing etc. (Excavation foot rest and external cement plaster shall be paid for separately) 29.8 Manhole for property (House) connection 29.8.1 Inside size 60x60 cm and 90 cm deep manhole with fixing of ISI marked pre cast RCC manhole cover & frame i/c transportation etc. 600x600 mm size heavy duty. Nos 200.00 8777.00 7 15.37 Steel work in welded built-up section/ framed work, including cutting hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. 15.37.2 In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works Kg 300.00 101.00 8 4.5 Providing and laying in position including testing following PVC bends suitable for 6, 8 and 10 Kg/Sq. cm. pressure pipes. 4.5.6 200 mm dia Clear Water Transmission Main from Narmada Tapping to Sump & Pumping main from Sump to OHT Earth work in excavation for foundation, trenches for pipes/ cables, drains or in well excavation etc. by mechanical means/ manual means (exceeding 30cm in depth.) including ramming of bottom, dressing of sides disposal of excavated earth including of all lift and lead upto 50m. Disposed earth to be levelled and neatly dressed. 15.6.1 All kinds of soil. 200 mm Dia Cum 818 Sub total 818 209 2 15.6 Earth work in excavation for foundation, trenches for pipes/ cables, drains or in well excavation etc. by mechanical means/ manual means (exceeding 30cm in depth.) including ramming of bottom, dressing of sides disposal of excavated earth including of all lift and lead upto 50m. Disposed earth to be levelled and neatly dressed. 15.6.3 Ordinary rock or soft rock with or without blasting 200 mm Dia Cum 818 Sub total 818 270 3 15.6 Earth work in excavation for foundation, trenches for pipes/ cables, drains or in well excavation etc. by mechanical means/ manual means (exceeding 30cm in depth.) including ramming of bottom, dressing of sides disposal of excavated earth including of all lift and lead upto 50m. Disposed earth to be levelled and neatly dressed. 15.6.4 Hard rock (requiring blasting) 200 mm Dia Cum 921 Sub total 921 491 4 15.13 Supplying & filling moorum for pipe bedding or over the pipe (including supply of moorum). 10 cm will be depth of moorum bedding 200 mm Dia Cum 204.60 Sub total 204.60 649 5 1.3 Providing, laying and jointing including testing following socket & spigot centrifugally cast (Spun) Ductile Iron pressure pipes with inside cement mortar lining (class K-9) conforming to IS 8329/2000 with suitable Rubber Gasket (Push on) joints as per IS:5382/85 200 mm Dia RMT 3300 3202.00 6 14.1 Labour for cutting following Ductile iron pipes of any type and class. per cut 1 295.00 14.1.6 300 mm dia 7 1.11 Providing and Laying including testing Ductile Iron Double Socket 90° Bends conforming to IS:9523/2000 having dimension as per table 15 of IS:9523/2000 in the following nominal diameter/sizes with external bitumen coating and internal cement mortar lining. 1.11.3 200 mm dia No 2 5048.00 8 1.13 Providing and Laying Ductile Iron Double Socket 90° Bends conforming to IS-9523/2000 having dimension as per table 15 of IS9523/2000 in the following nominal diameter/sizes with external bitumen coating and internal cement mortar lining. 1.13.3 200 mm dia No. 7 4698.00 9 1.15 Providing and Laying including testing Ductile Iron Double Socket 45° Bends conforming to IS- 9523/2000 having dimension as per table 16 of IS- 9523/2000 in the following nominal diameter/sizes with external bitumen coating and internal cement mortar lining. 1.15.4 200 mm dia No. 6 3416.00 Measurement & Abstract Sheet Clear Water Transmission Main from Narmada Tapping to Sump & Pumping main from Sump to OHT Clear Water Transmission Main from Narmada Tapping to Sump and OHT Sr. No. MP PHE SOR 2023 Description of Item Unit Qty Rate 10 1.17 Providing and Laying including testing Ductile Iron Double Socket 22.5° Bends conforming to IS- 9523/2000 having dimension as per table 17 of IS- 9523/2000 in the following nominal diameter/sizes with external bitumen coating and internal cement mortar lining. 1.17.4 200 mm dia No. 5 2786.00 11 1.19 Providing and Laying including testing Ductile Iron Double Socket 11.25° bends conforming to IS-9523/2000 having dimension as per table 18 of IS- 9523/2000 in the following nominal diameter/ sizes with external bitumen coating and internal cement mortar lining. 200 mm dia No. 5 2643.00 12 1.41 Providing & fixing of following Ductile iron double flanged sluice valves as per IS :14846-2000 fitted with cap including jointing & testing with cost of jointing material such as bolts, nuts, rubber insertions etc. all complete.P.N 1.6 200 mm dia No 6 34084 13 8.65(a) Providing & fixing following cast iron double flanged single door reflux (non return) valves including jointing & testing with cost of jointing material such as bolts, nuts and rubber insertion all complete as per IS :5312 (Part I) P.N 1.0 8.65(a).6 200 mm dia No 1 12345 14 1.50 Providing & fixing following ductile iron single chamber triple function temper proof air valves, small orifice with screwed end as per IS:14845- 2000 including jointing & testing with cost of jointing material and rubber insertion all complete as per IS:13095-1991.PN1.0 1.50.1 50 mm dia No 6 9630 15 15.66 Construction of Brick masonry valve chamber with 20 cm thick wall in 1:6 C.M. with 12mm thick 1:4 Cement Plaster and base course 10 cm. thick in M-15. Inside Dimensions 110x80x100cm M-20 RCC chamber cover size 130x120cmx10cm including cost of materials, labour, finished with floating coat of neat cement etc. complete. For Air Valve+ Sluice Valve No 13 9345 16 1.21 Providing and Laying including testing Ductile Iron All socket Tees conforming to IS-9523/2000 having dimension as per table 21 of IS9523/2000 in the following nominal diameter/sizes with external bitumen coating and internal cement mortar lining with finishing as per clause 13 of IS-9523/2000. No 1.21.7 200 mm x 100 mm Dia 2 3985 17 15.11 Filling available excavated earth in trenches, plinth sides of foundation in layers not exceeding 20cm. in depth including consolidation of each layer by ramming watering, lead up to 50m and lift up to 1.5m in all kinds of soils Excavated Quantity Cum 2558 Deductions Pipe volume Cum 9.85 Chamber Cum 10.5 For Concrete Cum 0.0 For murum bedding Cum 204.60 Total Filling Quantity Cum 2332.52 47 Clear Water Transmission Main from Narmada Tapping to Sump and OHT Sr. No. MP PHE SOR 2023 Description of Item Unit Qty Rate 18 13.3 Electromagnetic Bulk Flow Meters Supply of Electromagnetic full bore meter complete as per specification including transportation to site, storage, safety, installation, testing, commissioning, making connections with existing pipe line, including excavation at site, cuts in the existing pipe system, dewatering and reinstating the same after completion of installation as per specification and drawings including all taxes. Accuracy of meter + 0.3% of measured value, Flange connection as per AWWA & IS, Liner:Hard Rubber, Fully welded sensor housing complying to IP 68 standard, Electrodes SS 316, Sensor housing SS 304, Cable gland 1/2 NPT, Sensor housing fully welded SS 304 housing with protective Polyurethane paint, Flow Transmitter/ Converter: Microprocessor based, modular design display 2 line back lit LCD for indication of actual flow rate, forward, reverse, sum totalizer, Perfection category: IP 65 Output: One current output (4-20 mA) one scalable pulse output 13.3.6 200 mm dia Distribution Network from OHT - Earth work in excavation for foundation, trenches for pipes/ cables, drains or in well excavation etc. by mechanical means/ manual means (exceeding 30cm in depth.) including ramming of bottom, dressing of sides disposal of excavated earth including of all lift and lead upto 50m. Disposed earth to be levelled and neatly dressed. 15.6.1 All kinds of soil. 100 mm dia DI K-7 pipes Cum 5782 Sub total 5782 209 5 1.1 Providing, laying and jointing including testing following socket & spigot centrifugally cast (Spun) Ductile Iron pressure pipes with inside cement mortar lining (class K-7) conforming to IS 8329/2000 with suitable Rubber Gasket (Push on) joints as per IS:5382/85 100 mm dia DI K-7 pipes RMT 5900 1500.00 6 1.11 Providing and Laying Ductile iron Mechanical joint collar with follower glands conforming to IS-9523/2000 having dimension as per table 24 of IS-9523/2000 in the following nominal diameter/sizes with external bitumen and internal cement mortar lining 1.11.1 For 100 mm dia DI K-7 pipes Each 10 1527.00 7 1.13 Providing and Laying Ductile Iron Double Socket 90° Bends conforming to IS-9523/2000 having dimension as per table 15 of IS9523/2000 in the following nominal diameter/sizes with external bitumen coating and internal cement mortar lining. 1.13.1 For 100 mm dia DI K-7 pipes Each 10 1527.00 8 1.15 Providing and Laying including testing Ductile Iron Double Socket 45° Bends conforming to IS- 9523/2000 having dimension as per table 16 of IS- 9523/2000 in the following nominal diameter/sizes with external bitumen coating and internal cement mortar lining. 1.15.1 100 mm diameter Each 13 1316.00 9 1.17 Providing and Laying including testing Ductile Iron Double Socket 22.5° Bends conforming to IS9523/2000 having dimension as per table 17 of IS9523/2000 in the following nominal diameter/sizes with external bitumen coating and internal cement mortar lining. 1.17.1 100 mm diameter Each 13 1232.00 Distribution Network from OHT WATER SUPPLY | DISTRIBUTION NETWORK FROM OHT Sr. No. MP PHE SOR 2023 Description of Item Unit Qty Rate 10 1.21 Providing and Laying including testing Ductile Iron All socket Tees conforming to IS-9523/2000 having dimension as per table 21 of IS-9523/2000 in the following nominal diameter/sizes with external bitumen coating and internal cement mortar lining with finishing as per clause 13 of IS9523/2000. 150mm x 150mm dia 1.21.1 100 mm x 100 mm Each 10 2104.00 11 1.41 Providing & fixing of following Ductile iron double flanged sluice valves as per IS :14846-2000 fitted with cap including jointing & testing with cost of jointing material such as bolts, nuts, rubber insertions etc. all complete. P.N 1.1 1.41.2 100 mm diameter Each 8 11519 12 1.5 Providing & fixing following ductile iron single chamber triple function temper proof air valves, small orifice with screwed end as per IS:14845-2000 including jointing & testing with cost of jointing material and rubber insertion all complete as per IS:13095-1991.PN1.0 50 mm diameter No 10 9630 13 15.66 Construction of Brick masonry valve chamber with 20 cm thick wall in 1:6 C.M. with 12mm thick 1:4Cement Plaster and base course 10 cm. thick in M-15. Inside Dimensions 110x80x100cm M-20 RCC chamber cover size 130x120cmx10cm including cost of materials, labour, finished with floating coat of neat cement etc. complete. For Air Valve+ Sluice Valve No 8 9345 14 15.11 Filling available excavated earth in trenches, plinth sides of foundation in layers not exceeding 20cm. in depth including consolidation of each layer by ramming watering, lead up to 50m and lift up to 1.5m in all kinds of soils Excavated Quantity Cum 5782 47 WATER SUPPLY | DISTRIBUTION NETWORK FROM OHT Sr. No. MP PHE SOR 2023 Description of Item Unit Qty Rate 15 13.3 Electromagnetic Bulk Flow Meters Supply of Electromagnetic full bore meter complete as per specification including transportation to site, storage, safety, installation, testing, commissioning, making connections with existing pipe line, including excavation at site, cuts in the existing pipe system, dewatering and reinstating the same after completion of installation as per specification and drawings including all taxes. Accuracy of meter + 0.3% of measured value, Flange connection as per AWWA & IS, Liner:Hard Rubber, Fully welded sensor housing complying to IP 68 standard, Electrodes SS 316, Sensor housing SS 304, Cable gland 1/2 NPT, Sensor housing fully welded SS 304 housing with protective Polyurethane paint, Flow Transmitter/ Converter: Microprocessor based, modular design display 2 line back lit LCD for indication of actual flow rate, forward, reverse, sum totalizer, Perfection category: IP 65 Output: One current output (4-20 mA) one scalable pulse output Clear Water Sump - Design, drawing, construction, testing and commissioning of R.C.C. GSR/Sump well of following capacities with all necessary fitting and accessories as mentioned in the relevant chapter of USOR, IS codes and departmental circulars Complete turn key job for following capacities: Over Head Tank Design, drawing, construction, testing and commissioning of RCC Elevated Service Reservoir/ Over Head Tank (ESR/OHT) with all necessary fitting as mentioned in relevant chapter of USOR, IS code and departmental guidelines. Complete turn key job for following capacities with 9/12/15 meterstaging height from GL:- 18.3 15 Mtr. Staging 18.3.15 400 Kilo Litres Each 2 14.17 Providing and installation of automatic water level indicator for supervisory control cum auto on/off of motor pump assembly inclusive of control panel, 500 mtr long 2 core, 4 pair cable for small rural water supply scheme, having source within 500mtr as per approved specification and as directed by Engineer in charge. In case of lesser length of cable, equivalent amount @ Rs 12 /-per meter of short length will be deducted from above rate) Effluent Network Dismantling Of Existing Structures like Culverts, Bridges ,Retaining Wall and Other Structures ComprisingOf Masonary,Cement Concrete, wood work , Steel Work, Including T&P and Scaffolding, whereever necessary, Sorting The dismantled Material, Desposal Of Unserviceable Materialand Stacking The Serviceable Material With All Lifts and LeadsOf 1000metres C Prestressed/ Reinforced Cement Concrete Grade M-25& Above cum 105 1170.00 2 PHE USOR 2023 15.6 Earth work in excavation for foundation, trenches for pipes/ cables, drains or in well excavation etc. by mechanical means/ manual means (exceeding 30cm in depth.) including ramming of bottom, dressing of sides disposal of excavated earth including of all lift and lead upto 50m. Disposed earth to be levelled and neatly dressed. 15.6.1 All kinds of soil. For Pipe Cum 3150 for manhole chambers Cum 420 Sub total 3570 209 3 15.6 Earth work in excavation for foundation, trenches for pipes/ cables, drains or in well excavation etc. by mechanical means/ manual means (exceeding 30cm in depth.) including ramming of bottom, dressing of sides disposal of excavated earth including of all lift and lead upto 50m. Disposed earth to be levelled and neatly dressed. 15.6.3 Ordinary rock or soft rock with or without blasting For RCC Pipe Cum 6615 for manhole chambers Cum 1260 Sub total 7875 270 4 15.6 Earth work in excavation for foundation, trenches for pipes/ cables, drains or in well excavation etc. by mechanical means/ manual means (exceeding 30cm in depth.) including ramming of bottom, dressing of sides disposal of excavated earth including of all lift and lead upto 50m. Disposed earth to be levelled and neatly dressed. 15.6.5 Hard rock (requiring chiseling where blasting prohibited) For Pipe Cum 2205 for manhole chambers Cum 420 2625 722 5 15.13 Supply & Filling with moorum for pipe bedding or over the pipe including supply of moorum 300 mm Dia, RCC NP3 Cum 441.00 Sub Total 441.00 643 6 28.3 Providing and Laying non-pressure (NP3) RCC socket & spigot pipes with rubber gasket joint including testing of joints. 28.3.3 300 mm RMT 6300 1123.00 Effluent Network EFFLUENT NETWORK Sr. No. SOR Details Description of Item Unit Qty Rate 29.13 Constructing Brick Masonry Circular Man Hole 900 mm internal dia at bottom & 560 mm dia at top in cement Mortar 1:4 (1 cement: 4 fine sand), inside Cement plaster 12 mm thick with cement mortar 1:3 (1 cement : 3 fine sand) finished with a floating coat of neat cement, foundation concrete 20 cm thick in 1:3:6 ( 1 cement : 3 fine sand : 6 graded stone aggregate 40 mm nominal size ) and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement etc. all complete. 29.13.1 For one Manhole 900mm deep with fixing of 560 mm dia ISI marked reinforcement cement concrete cover & frame heavy duty including transportation etc. in cement concrete 1:2:4 all complete. ( Excavation, foot rests & cement plaster at the external surface shall be paid for separately) Each 50 12020.00 7a 29.13.2 Add extra for depth 0.90 to 1.65 mtr. each 15 4808.00 8 29.12 Constructing Brick Masonry Circular Man Hole 1200 mm internal dia at bottom & 560 mm dia at top in cement Mortar 1:4 (1 cement: 4 fine sand), inside Cement plaster 12 mm thick with cement mortar 1:3 (1 cement : 3 fine sand) finished with a floating coat of neat cement, foundation concrete 20 cm thick in 1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size ) and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement etc. all complete. 29.12.1 For one manhole upto 1650 mm deep with fixing of 560 mm dia ISI marked reinforcement cement concrete cover & frame heavy duty including transportation etc. in cement concrete 1:2:4 all complete. ( Excavation, foot rests & cement plaster at the external surface shall be paid for separately) Each 100 17593.00 29.12.2 Add extra for depth1.65 mtr. to 2.3m each 30 7037.00 29.10 Constructing Brick Masonry Circular Man Hole 1500 mm internal dia at bottom & 560 mm dia at top in cement Mortar 1:4 (1 cement: 4 fine sand), inside Cement plaster 12 mm thick with cement mortar 1:3 (1 cement : 3 fine sand) finished with a floating coat of neat cement, foundation concrete 20 cm thick in 1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size ) and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cementetc. all complete. 29.10.1 For one manhole upto 2650 mm deep with fixing of 560 mm dia ISI marked reinforcement cement concrete cover & frame heavy duty including transportation etc. in cement concrete 1:2:4 all complete. ( Excavation, foot rests & cement plaster at the external surface shall be paid for separately) Each 60 27395.00 29.11 Extra for depth for circular manholes over item 15.4 29.11.1 Depth 2.65m to 4.25 m each 18 12258.00 29.14 Providing MS foot rests i/c fixing in manhole with 20x20x10cm CC blocks of 1:3:6 (1 cement:3 coarse sand : 6 graded stone aggregate 20mm nominal size ) 29.14.2 With 20mm round bar foot rest each 640 249.00 7 9 10 11 EFFLUENT NETWORK Sr. No. SOR Details Description of Item Unit Qty Rate 12 15.11 Filling available excavated earth in trenches, plinth sides of foundation in layers not exceeding 20cm. in depth including consolidation of each layer by ramming watering, lead up to 50m and lift up to 1.5m in all kinds of soils RECYCLED (TREATED ) WATER DISTRIBUTION FROM STP TO CONSUMER Earth work in excavation for foundation, trenches for pipes/ cables, drains or in well excavation etc. by mechanical means/ manual means (exceeding 30cm in depth.) including ramming of bottom,dressing of sides disposal of excavated earth including of all lift and lead upto 50m. Disposed earth to be levelled and neatly dressed. Cum 15.6.3 Ordinary rock or soft rock with or without blasting 110 mm ∅ HDPE PE-100 6 Kg/cm Cum 1491.00 1491.00 270.00 15.6.5 Hard rock (requiring chiseling where blasting prohibited) 110 mm ∅ HDPE PE-100 6 Kg/cm Cum 127.80 127.80 722.00 Cum 2 16.10 (a) Filling available excavated earth in trenches, plinth sides of foundation in layers not exceeding 20cm. In depth including consolidation of each layer by ramming watering, lead up to 50m and lift up to 1.5m in all kinds of soils Total Excavation 1618.80 110 mm ∅ HDPE PE-100 6 Kg/cm Cu. M. -56.99 Deduct Pipe Volume 1561.81 37.00 3 2.1 Providing, laying, Jointing & field testing of PE pipes made from 100% virgin material (Earlier know as hight Density Polyethylene pipes, PE 100) conforming to IS 4984/ 14151/12786/ 13488 with necessary jointing material like mechanical connector or jointing pipes by heating the ends of pipes with the help of Teflon coated electric mirror/ heater to the required temperature and then mechanically pressing the ends together against each other, to form a monolithic & leak proof joint by thermosetting process. It may be required to be done with Jacks/Hydraulic Jacks/But fusion machine. (50mm & above fusion jointed & below 50mm mechanical jointed) 10Kg/sq.cm 2.1.6 110 mm ∅ HDPE PE-100 Rm 6000.00 493.00 4 2.2 Providing and laying including testing Bend90ْ conforming to IS specifications. 2.2.6 110 mm ∅ HDPE PE-100 Each 8.00 383.00 5 2.3 Providing and laying Bend 45’ confirming to IS specification 2.3.4 110 mm ∅ HDPE PE-100 Each 8.00 455.00 6 2.4 Providing and laying Equal Tee confirming to IS specification 2.4.4 110 mm ∅ HDPE PE-100 Each 5.00 571.00 RECYCLED (TREATED ) WATER DISTRIBUTION FROM STP TO CONSUMER S. No. MP PHE 2023 Particulars Unit RECYCLE WATER NETWORK Qty. Rate S. No. MP PHE 2023 Particulars Unit 7 2.5 Providing and laying Pipe end confirming to IS specification. Pressure 2.5.4 110 mm ∅ HDPE PE-100 Each 2.00 232.00 8 2.7 Providing butt fusion welded joint/ jointing by heating to the ends with the help of Teflon coated electric mirror/heater ends together etc. by thermosetting process to PE- 100 pipe and specials. (6kg, 8kg, 10kg) (50mm & above fusion jointed & below 50mm mechanical jointed) including testing. 2.7.4 110 mm ∅ HDPE PE-100 Each 5.00 164.00 9 8.62 Providing & fixing of following Cast iron double flanged sluice valves as per I.S.:14846-2000 fitted with cast iron cap including jointing & testing with cost of jointing material such as bolts, nuts, rubber insertions etc. all complete PN-1.0 8.62.4 100mm ∅ Each 5.00 5097.00 10 8.67 Providing & fixing following cast iron butterfly valves including jointing & testing with cost of jointing material such as bolts,nuts and rubber insertion all complete as per IS :13095- 1991 CLASS PN-1.0 8.67.4 100 mm Each 3.00 3217.00 11 15.66 Construction of Brick masonry valve chamber with 20 cm thick wall in 1:6 C.M. with 12mm thick 1:4 Cement Plaster and base course 10 cm. thick in M-15. Inside Dimensions 110x80x100cm M-20 RCC chamber cover size 130x120cmx10cm including cost of materials, labour, finished with floating coat of neat cement etc. complete. Each 13.00 9345.00 15.32 Providing & laying mechanically mixed R.C.C. excluding centering & shuttering and reinforcement in foundation/plinth (20mm graded metal) 15.32.1 1:1.5:3 (M 20) CUM 72.00 5916.00 13 16.25(a) Providing and placing in position cold twisted steel and hot rolled deformed steel reinforcement for R.C.C. work i/c cutting, bending, binding etc. complete i/c cost of binding wire and wastage. Sub Structure Kg 432.00 68.00 12 OHT Sr. No. MP PHE SOR 2023 Description of Item Unit Qty Rate 1 18 Design, drawing, construction, testing and commissioning of RCC Elevated Service Reservoir/ Over Head Tank (ESR/OHT) with all necessary fitting as mentioned in relevant chapter of USOR, IS code and departmental guidelines. Complete turn key job for following capacities with 9/12/15 meterstaging height from GL:- 18.3 15 Mtr. Staging 18.3.3 100 Kilo Litres Each 2 14.17 Providing and installation of automatic water level indicator for supervisory control cum auto on/off of motor pump assembly inclusive of control panel, 500 mtr long 2 core, 4 pair cable for small rural water supply scheme, having source within 500mtr as per approved specification and as directed by Engineer in charge. In case of lesser length of cable, equivalent amount @ Rs 12 /-per meter of short length will be deducted from above rate) Each 1 18000 Over Head Tank DISMANTLING WORKS Dismantling of Cement Concrete Pavement Dismantling of cement concrete pavement by mechanical means using pneumatic tools, breaking to pieces not exceeding 0.02 cum in volume and stock piling Serviceable material at designated locations and disposal of unserviceable materials up to a lead of 1000 metres, CUM 100.00 1,283.00 2 2.1 Cutting of Trees, including Cutting of Trunks, Branches and Removal Cutting of trees, including cutting of trunks/branches in suitable size removal of stumps/roots, and stacking of serviceable material with all lifts and up to a lead of 1000 mtrs and filling earth in the depression/pit.. i Girth from 300 mm to 600 mm No 10.00 244.00 3 2.13 Removal of Telephone / Electric Poles and Lines Removal of telephone / Electric poles including excavation and dismantling of foundation concrete and lines under the supervision of concerned department, disposal with all lifts and up to a lead of 1000 metres and stacking the serviceable and unserviceable material separately. Each 10.00 168.00 4 2.3 Dismantling of Structures Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood, steel, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead upto 1000 metres. (i) Lime /Cement Concrete B Cement Concrete Grade M-15 & M-20 Cum 75.00 425.00 (ii) Dismantling Brick / Tile work B In cement mortar Cum 270.00 282.00 15.13 Taking out existing CC interlocking paver blocks from Sqm 750.00 31 11.43.3 UADD BUILDING SOR 2021(AMM ENDMENT) Laying old cement concrete interlocking paver blocks of anydesign/shape laid in required line, level, curvature, colour and pattern over and including 50mm thick compacted bed of sand, filling the joints with sand including cost of paint, eie all complete as per the direction of Engineer-in-charge. Sqm 750.00 142 DISMANTLING WORKS Horticulture S.No SOR Description Unit Quantity Rate 1 MPPWD Building SOR2024 28.1 Trenching in ordinary soil up to a depth of 60cm including removal and stacking of serviceable materials and then disposing of by spreading and neatly levelling with in a lead of 50m and making up the trenched area to proper levels by filling with earth or earth mixed with sludge or/and manure before and after flooding trench with water (excluding cost of imported earth, sludge or manure). Cum 150 186 2 MPPWD Building SOR2024 28.2 Supplying and stacking of good earth at site including royalty and carriage up to 1 km (earth measured in stacks will be reduced by 20% for payment). Cum 30 511 3 MPPWD Building SOR2024 28.3 Supplying and stacking sludge at site including royalty and carriage up to 1 km (sludge measured in stacks will be reduced by 8% for payment). Cum 3 643 4 MPPWD Building SOR2024 28.9 Mixing earth and sludge or manure in proportion specified or directed. Cum 3 11 5 MPPWD Building SOR2024 28.8 Spreading of sludge, dump manure or/and good earth in required thickness (Cost of sludge, dump manure or/ and good earth to be paid separately). cum 3 16 6 MPPWD Building SOR 2024 28.15 Providing and planting different variety of plants of approved quality and sizes as mentioned including making pits of required size at site, refilled with B.C. Soil mixture manuring and pesticide etc. complete (to be paid separately) including watering and 90 days maintenance from the date of final bill as per direction of Engineer-in-Charge complete in all respect (B.C. Mixture paid separately) 7 MPPWD Building SOR 2024 28.15.1 Bahunia Tomentosa, Beloperone Species, Caselpinnia Pulcherima, Bird of Paradise, Callandra Emarginata, Callandra Hybrida, Cassia Bi flora, Cassia Laevigata, Cestrum Nocturnum, Dombeya Mastersii, Euphorbia Caracasana, Euphorbia Pulcherima, Excorea bi color, Excorea tri color, Ficuas Blackii, Ficus Reginold, Ficus Panda, Gardenia, Gulphinia, Jasminoides, Hamelia Pattens, Heliconia, Hibiscus Rosasinensis, Hibiscus Verigated, Hibiscus Viceroy, Jatropha Multifida, Largestomia Indica, Malpighia Coccigera, Murraya Exotica, Murraya Koeniggi, Murraya Sambucum, Mussaenda Erythrophylla, Nerium Oleander, Nyctanthus Arbortristis, Plumbego Capensis, Putranjeeva Roxburghii, Tabernaemontana Coronaria, Tabernaemontana Divaricata, Tecoma Gaudi Chaudi, Tecoma Stans, Thevetia Nerifolia, Thuja Compacta and equivalent plants Nos 232.00 80.00 8 MPPWD Building SOR 2024 28.15 Providing and planting different variety of plants of approved quality and sizes as mentioned including making pits of required size at site, refilled with B.C. Soil mixture manuring and pesticide etc. complete (to be paid separately) including watering and 90 days maintenance from the date of final bill as per direction of Engineer-in-Charge complete in all respect (B.C. Mixture paid separately). Horticulture Bahunia Tomentosa, Beloperone Species, Caselpinnia Pulcherima, Bird of Paradise, Callandra Emarginata, Callandra Hybrida, Cassia Bi flora, Cassia Laevigata, Cestrum Nocturnum, Dombeya Mastersii, Euphorbia Caracasana, Euphorbia Pulcherima, Excorea bi color, Excorea tri color, Ficuas Blackii, Ficus Reginold, Ficus Panda, Gardenia, Gulphinia, Jasminoides, Hamelia Pattens, Heliconia, Hibiscus Rosasinensis, Hibiscus Verigated, Hibiscus Viceroy, Jatropha Multifida, Largestomia Indica, Malpighia Coccigera, Murraya Exotica, Murraya Koeniggi, Murraya Sambucum, Mussaenda Erythrophylla, Nerium Oleander, Nyctanthus Arbortristis, Plumbego Capensis, Putranjeeva Roxburghii, Tabernaemontana Coronaria, Tabernaemontana Divaricata, Tecoma Gaudi Chaudi, Tecoma Stans, Thevetia Nerifolia, Thuja Compacta and equivalent plants. EACH 2000 80.00 8b MPPWD Building SOR 2024 28.15.5 Alpinia Verigated, Alternanthera species, Aspyragus Myerri, Aspyragus Springenii, Aspidistra, Canna (regular, Dwarf), Chlorodendron Inermii, Chlorophytum (Green), Chlorophytum verigated, Coffea Chinensis, Dianella Verigated, Durranta (Goldiana, Green, Verigated), Euphorbia Milli hybrid, Ipomea (Golden leaves), Iresine herbstii, Juniper Prostata, Juniper Africana, Ophiopogon plant, Ophiopogon jaburan, Portulacaria Afra (jade Plant), Schefflera Green, Schefflera verigated, Setcreasea Purpurea, Syngonium (Butterfly) species, Syngonium miniature, Syngonium Dwarf, Syngonium variegated, Tradescantia, Wadelia Trilobata, Zebrina Tradescantia, Pendanas, Spider Lily Black, Spider Lily verigated, Aclypha (Red, Green,Mini), Lantana (Red, Yellow, Purple, White, verigated), Haemalia Mini and similar plants. 100 KVA TRANSFORMER WITH DP STRUCTURE ITEM BASED ON MPPWD S0R 2024 1 37.9 Supply and laying 25mm X 5mm G.I. strip at 0.5 metre below ground level as strip earth electrode including jointing etc. as required. Metre 30 130 2 37.17 Providing and fixing 4.0mm (8 SWG) dia G.I. wire on surface or in recessed for loop earthing as required Metre 10 30 3 37.40 Supply and erection of approved make safe earthing electrode consisting pipe-in- pipe technology as per IS 3043-1987 made of corrosion free G.I. pipes with constant ohmic value surrounded by highly conductive compound with high charge dissipation suitable for effective and maintenance free earthing in earth pit of minimum bore dia. 150mm size, as mentioned below : 37.40.2 With 3 metre G.I. pipes having outer pipe dia of 50mm having 80-200 micron galvanizing, Inner pipe dia. of 25mm having 200-250 Micron galvanizing, connection terminal dia. of 12mm in nominal soil with 50 kg (two bag) back filling bentonite compound UL listed and confirm to relevant International/Indian standards around electrode upto ground level. Each 6 13140 7 41.12 Supplying & installing G.I. pipe for protection of underground cable fixed on wall/support/in trench/fixed between two rigid existing support of wall/beam for erection of ceiling Fan/down rod for stiff pendent for light luminaries /fan/protective for earthing, lightening conductor down strip/overhead service line/for submersible cable or centrifugal pump for water supply with necessary iron clamp coupler, bend, tee, elbow, nuts and bolts etc. complete in an approved manner as required to complete excluding cost of excavation/dismantling & other finished masonry Item complete. 41.12.1 For B class pipe ISI marked (IS-1161-68) 41.12.1.6 50.00mm Metre 30 550 42.70 Supplying, installing, testing and commissioning of 11/0.4 KV 3 Phase 50 cycle oil immersed, naturally cooled, outdoor type transformer connected delta on H.T. side and star on L.T. side, dehydrating silica gel breather on eye level, rating and diagram plate, two earthing terminal, lifting lugs, oil level gauge, drain valve with plug, temperature not exceeding 50ºC on load, oil filling hole with plug, four unidirectional roller, arcing horns, explosion vent, terminal arrangement bushing on H.V. side and cable box on LV side, first filling of oil upto desired level and transformer installing on existing structure with all required materials arrangement as required ISI marked & as per IS specification, hand operated off load tap changer switch above 100 KVA, oil conservator with drain valve, plug 63 KVA and above. 42.70.3 Aluminium wound 42.70.3.3 100 KVA Each 1 348160 100 KVA TRANSFORMER WITH DP STRUCTURE S. No. Sub Item No. Description of Item Unit Qty Rate (in Rs) 100 KVA TRANSFORMER WITH DP STRUCTURE S. No. Sub Item No. Description of Item Unit Qty Rate (in Rs) 42.2 Supply of support for overhead line RS joist of I.S. standard including drilling of required hole etc. complete as required. 42.2.6 H - Beam 152x152mm, Std weight 37.1 Kg/Mtr Mtr. 104 2843 42.58 Supplying and erection of single piece nonlinear resistor type lighting arrestor (set of 3 nos) for 3 wire, 11KV overhead lines/sub-station with rated voltage of 9KV (rms) with a nominal discharge current rating of 5 KA and complete with galvanized clamping arrangement, G.I. bolts, nuts, washer etc. as required. Set 1 3832 42.63 Supplying installing, testing & commissioning D.O. fuse assembly with brass part contact for 33 or 11/0.4 KV DP Structure set of 3 Nos. with fuse barrel i/c required fuse element & other materials as per specification on existing D.P. structure as required. 42.63.1 11KV Set 1 4721 42.44 Supplying and erection of 11KV porcelain pin insulator complete with long steel head G.I. pin, nut, washer etc. as required. Each 12 375 42.45 Supplying and erection of 11KV porcelain disc insulator for 11KV overhead lines with galvanized insulator fittings, ball and socket type, and complete with galvanized strain clamp, bolts, nuts washer etc. as required Each 6 750 17 29.27 Supply, fixing, testing & commissioning wall/floor mounted LT panel primer coated with powder coated paint & provided with required gasket for dust/vermin proof with degree of protection IP42 suitable for 415Volt 3 phase, 50 Hz, 4 wire system fabricated out of CRCA sheet upto 2 mm thick (1.6 mm for doors) duly compartmentalized for incomer, bus section, outgoings, cable alleys & CT, PT Ampere Metre, Volt Metre, selector switches, frequency Metre, phase indicating lamp, Energy Metre complete including cost of busbar supports, detachable cable gland plates, 2 earthing terminals, internal wiring & fixing of separately supplied MCBs, MCCBs, ACB, panel mounted changeover switch/SFUs, etc. as required but excluding cost of busbar strips, Ampere Metre, Volt Metre, selector switch as per approved design & specification kg. 250 397 18 29.28 Supply and fixing of LT panel accessories of approved make in existing LT panel including connections etc. as required as per specification. 29.28.6 Aluminium bus bar strips with PVC sleeves kg 25 284 29.28.6 LED lamp indicator Each 3 255 20 42.68 Supply, laying and fixing of G.I. earth coil of 4mm dia G.I. wire having 120 turns of nearly 50mm dia. and 3 mt. long tail in existing pit duly earthed with pole etc complete as required as per specification. Each 5 293 21 42.69 Supplying and fixing 33/11/0.4 KV enamel coated danger board size 200x250mm with clamp on existing HT/LT structure/poles. Each 1 205 100 KVA TRANSFORMER WITH DP STRUCTURE S. No. Sub Item No. Description of Item Unit Qty Rate (in Rs) 42.5 Supplying and drawing all aluminium alloy conductor (AAAC) of approved make conforming to IS 398-1979 Pt. IV, including binding at existing insulator, jointing, jumpering, tearing off, connecting etc. as required including clearing of obstacles (if any) 42.5.4 AAAC 0.1 sq inch (100 sq.mm Al. EQ.)- (Dog) Km. 0.5 104339 27.1 Supply of ISI marked and approved make of moulded case circuit breaker (MCCB) suitable for 3 phase,3 pole, 50 Hz, 415 Volts, AC supply with respective interrupting capacity (KA) at 415 Volts cited against their range standard conforming to IS – 8828 27.1.10 MCCB 36kA current rating, 3P -315Amp &adjustable: 80% -100% thermal Each 1 23636 27.1.4 MCCB 25kA current rating, 3P -125Amp & 80% -100% adjustable Each 3 9953 41.1 Supply of XLPE insulated power cable (conforming IS-7098 Part-I) 1100 Volt grade, 1 core/2 core/3½ core/4 core ISI marked with alu. stranded /solid conductor 41.1.1 Unarmoured 1 core 41.1.1.5 70 sq. mm. Metre 12 143 42.42 Supply, fabrication and erection of angle/channel/flat iron fitting for overhead line & sub-station etc such as D bracket, cross arms, top clamp, V cross arms, back/support clamp or other similar work etc. including nut bolts of required size, making holes, fabrication, welding, cutting, etc. and painting with one coat of red oxide paint & two coat of aluminium paint as required as per specification. Kg 250 105 42.116 Supply, installation, testing & commissioning of LT trivector energy meter, DLMS compliant category-A (for substation/feeder metering) , 3 phase 4 wire, 440 Volts, 5 Amp, accuracy class 0.5S with GSM(GPRS compatible) modem suitable for required C.T. 5A duly tested from electricity board with uPVC box . Each 1 14882 41.7 Supplying and fixing crimping type alum. lugs as per I.S.S. specification suitable for following size of cable with alu./copper solid/stranded conductor evenly crimped with high/pressure tool and connected to switch gear/bus/M.C.C.B./M.C.B. etc. as required complete. 41.7.5 70 sq. mm Each 6 35 42.78 Supply of hand gloves 11KV tested Set 1 1077 42.81 Supply of fiber D.O operating rod for 11/33KV tested Each 1 3854 42.82 Supply of first aid box complete with medicine & bandage as per specification. Each 1 1646 42.83 Supply of shock instruction chart duly framed with glass, as reqd. Each 1 537 ROAD LIGHTING WORK S. N. MPPWD SOR 2024 Description Unit Quantity Rate 1 27.8 Supply of ISI marked and accepted standard of miniature circuit breaker (MCB) of C series with short circuit indication, suitable for 240/415 Volts,50 Cycle, 10 kA/15 kA Value AC supply conforming to IS : 8828 : 1996, IEC : 60898 :2002 & 60947-2 but without enclosures : A 27.8.1 SINGLE POLE (SP) B 27.8.1.2 6 Amp to 32 Amp Rating 10 kA Each 120 263 2 28.4 Fixing of MCB /MCCB/ Isolator in sheet steel enclosure as required as per accepted practice, including mounting on busbar and cable connection etc. complete (Labour only ) 28.4.1 MCB / Isolator SP/DP Each 120 22 3 29.6 Supplying and fixing of multi core round HRFR / FR PVC insulated copper (flexible) conductor & PVC sheathed cables 1100 Volts as per IS:694-1990 of approved make A 29.6.3 ( 30 /0.25 mm ) Three core 1.5 sq.mm. Metre 2200 50 4 31.27 Supply & Fixing of Decorative LED Street Light of 1 to 3 watt with each , system lumens output with Efficacy>=135Im/W(@6500k), Its body made of Die cast aluminium using pressure die-casting process. Hole for coupling on pipes dia 60 mm. for lateral installation. Silicon gasket enusures the IP protection. IP Rating - IP66. Power LED Module with high efficacy LEDs on single Printed Circuit Board with metal core plate. Colour Rendering Index: Ra > 70. Electronic Power Supply for LED Module, which offers Protection against Short Circuit, Over- Voltage & OverCurrent. with in-built surge protection upto 4kv (an additional surge protection device of 10kV also provided in-built the fixture). PF>0.95 and THD<10%. Lens cover in PC (IK09). Estimated LED Lifetime is L70 @ 1,00,000 hours minimum. LM79-80 report from LED manufaturer should be submitted. Safety test report as per IEC 60598-2- 3;IEC 60598-1 / IS 10322 IEC 61347 i/c connection wire . testing etc-Supporting Test Report from NABL approved lab, with 5 year on site warranty. A 31.27.3 80/90W color temp 3000-6500k as required Each 110 14113 5 37.35.2 Providing and fixing earthing arrangement with 38.1mm dia2.5 metre long galvanized iron pipe electrode including packing of charcoal powder and salt as per specification watering pipe 19mm dia G.I. Connection, cover plate having locking arrangement on the top etc. complete with refilling the pit as required, including excavation of earth pit in soil / soft rock Each 20 3670 6 37.16 Providing and fixing 25mm X 4mm G.I. strip on surface or in recessed/concealed for connection etc. as required. Metre 30 130 7 42.68 Supply, laying and fixing of G.I. earth coil of 4mm dia G.I.wire having 120 turns of nearly 50mm dia. and 3 mt. Long tail in existing pit duly earthed with pole etc complete as required as per specification. Each 110 293 8 41.14 Supplying and installing Double wall corrugated pipes of HDPE ( IS 14930 Part II - marked ) for cable laid under ground with necessary material and at required depth upto 90cm. below road/ground surface, including excavation in all type soil & rock, back filling with excavated aterial, ramming and making the surface good. A 41.14.1 50.00mm outside dia. Metre 3700 133 9 41.1 Supply of XLPE Insulated power cable (confirming IS-7098 Part-I ) 1100 Volt grade, 1 core /2 core /3½ core/4 core ISI MARKED with Alu. Stranded /solid conductor 41.1.10 4 CORE ARMOURED A 41.1.10.3 16 Sq.mm Metre 3700 218 41.1.8 3½ CORE ARMOURED B 41.1.8.3 50 Sq.mm Metre 500 373 10 41.5 Supplying and fixing heavy duty cable gland for P.V.C. insulated armoured cable with brass washer, Rubber ring complete erected with cable and lead connection etc. as per specification complete A 41.5.1.3 Gland size 28mm for 3/4 X16 Sq.mm Each 246 138 B 41.5.1.4 Gland size 32 mm for 2/3, 3½, 4 x 25 sq.mm OR 2/3, 3½ x 35 sq. mm or 2/3/3½ x50 sq. mm. Each 10 158 11 41.6 Supplying and fixing ferrules as per IS - specification suitable for following size of cable for circuit identification including connection as required complete A 41.6.3 16.000 Sq mm Each 984 4 ROAD LIGHTINNG WORK 50.00 Sq.mm Each 40 11 12 41.7 Supplying and fixing cramping type Alum. lugs as per I.S.S. Specification suitable for following size of cable with Alu. /Copper solid/stranded conductor evently cramped with high/pressure tool and connected to switch gear/Bus/M.C.C.B./ M.C.B. etc. as required complete A 41.7.1 6 Sq.mm to 16.000 Sq mm Each 984 8 B 41.7.4 50 Sq.mm Each 40 22 13 41.15 Laying of one number armoured / unarmoured power cable 1.1kV grade of size not exceeding 25 Sq.mm direct in ground including excavation in all soil / murrum / soft rock, sand cushioining, protective covering and refilling the pit etc. as required. Metre 3700 230 14 41.15.7 Laying of one number armoured / unarmoured power cable 1:1 kV grade of size not exceeding 25 Sq.mm in the existing RCC Hume/Stone ware/G.I. pipe / DWC Pipe on surface in existing trench as required Metre 3700 28 15 41.15.32 Laying of one number armoured / unarmoured cable1.1kV grade of size exceeding 25 Sq.mm but not exceeding 120 Sq.mm on surface in existing trench etc.as required. Metre 500 33 16 42.98 Providing and erection of hot dipped galvanized octagonal poles in single section made from 3mm thick sheet having lockable weather proof flush door junction box, suitable size & type of foundation bolts 4 nos. J type (EN8 grade) complete, erected in an approved manner on provided foundation. A 42.98.7 9 meter height, 155 X 70mm A/F, 250x250x16mm base plate having weight 87 kg ± 3%, 4 nos. X 24 x 750mm bolt having weight 12 kg ± 3%. Each 110 15447 17 42.107 Providing and fixing of sword canopy type double arm GI bracket upto 2 Mtr. Long for 70mm A/F top octagonal pole Each 0 1573 18 42.100 Providing and fixing of sword canopy type single arm GI bracket upto 2 Mtr. Long for 70mm A/F top octagonal pole Each 110 1658 19 42.111 Designing and construction of footing foundation for octagonal pole of desired size including excavation in soil/soft rock, base concrete M-7.5 (1:4:8), 15mm thick and pedestal of RCC M-20 (1:1.5:3), required tor steel reinforcement for required size from base concrete, shuttering, curing etc. with existing foundation bolts complete as per specifications in an approved manner as per manufacturer drawing or engineer-incharge. P. Cum 26.73 6770 TOTAL FOR SOR ITEMS NON SOR ITEMS Supply of street light control panel for operating street light including MCCB contractors and others necessary items as per specification compelete dully painted with all norms at indutrial area for Textile park Jaora A) contractor- 40 Amp L & T B) Mccb-100 Amp L&T/ CG C) MCCB- 63 Amp Acio-Mefa D) Timer Standarad E) Cut out 100Amp F) Connecting Strip G) Bus Bar Installation of street light control Panel including excavation refilling with C:C 1:3:6 foundation and connection with required lugs existing pole/ MPEB Pole 21 NON SOR Each 5 75000 ETP Sl No Description Unit Rate Quantity A Survey , Investigation Design, Construction, Supply, Erection, Testing Commissioning of proposed Effluent Treatment Plant of Capacity 250 KLD expandable upto 500 KLD based on MBR process with 100% ZLD concept as per norms of CPBC/MOEF/MPPCB including one no Intermediate Effluent pumping stations along with complete infrastructure, campus boundary, campus development , utilities, inhouse laboratories, all necessary Civil, Piping, Mechanical, DG set and Electrical & Instrumentation works complete including 3 months trial run and Five Years Operation &Maintenance of complete facility after successful commissioning on turnkey basis. Plant shall be fully automated. (Rates to be quoted including consultancy cost of all necessrry permissions as mentioned in bid document, Operation & maintenanace and cost with all material & Manpower etc. Complete.) Lumsum 50000000 1 EFFLUENT TREATMENT PLANT(MBR PROCESS) -250 KLD EXPANDABLE UPTO 500 KLD ON ZLD CONCEPT
Contract Date: Aug 07, 2025 Contract Value : 11.15 Crore
Government Departments No of Bidders 5
Madhya Pradesh View Result →
35.
Defence #6918347 AOC
Tender For Preventive Maintenance And Repair Of Ht Installations At Af Stn Digaru (3Rd Call)- 1 Supply, joining and testing in repairs cable jointing kit for 11 KV (Earthed ) grade cable for outdoor termination, heat shrink type joint complete with and including jointing materials and accessories suitable for 11 KV XLPE insulated armoured aluminium cable of size 95 Sqmm 3 core, complete all as specified and as directed. 2 Supply, joining and testing in repairs cable jointing kit for 11 KV (Earthed ) grade cable for outdoor termination, heat shrink type joint complete with and including jointing materials and accessories suitable for 11 KV XLPE insulated armoured aluminium cable of size 185 Sqmm 3 core, complete all as specified and as directed. 3 Supply, joining and testing in repairs cable straight though cable jointing kit (Heat shrinkable type) for 11 KV (Earthed) grade cable complete with and including materials and including accessories suitable 3 core XLPE armoured aluminium conductor cable of size 95 Sqmm 3 core and including provision of aluminium thimbles, complete all as specified and as directed. 4 Supply, joining and testing in repairs cable jointing kit for 11 KV (Earthed ) grade cable for indoor termination, heat shrink type joint complete with and including jointing materials and accessories suitable for 11 KV XLPE insulated armoured aluminium cable of size 95 Sqmm 3 core, complete all as specified and as directed. 5 Supply, joining and testing in repairs cable jointing kit for 11 KV (Earthed ) grade cable for indoor termination, heat shrink type joint complete with and including jointing materials and accessories suitable for 11 KV XLPE insulated armoured aluminium cable of size 185 Sqmm 3 core, complete all as specified and as directed. 6 Supply and fixing GI tubing light grade 80mm bore for protection of cable, under road crossing, across drain, along electric pole or floor/ wall etc, complete including taking out existing pipe, complete all as specified and directed. 7 Boring/Drilling (horizontally) manually not exceeding 2mm deep in soli below existing roadsuitable for passing GI/MStubing of 80 to 200 mm bore, complete all as specified and directed. 8 Supply,laying testing cable XLPE insulated, screened PVC bedded, galvanised steel strip or wire armoured electric power cables (heavy duty) with aluminium conductor 11000 volts grade (Earthed) of size 95 sqmm 3 core including taking down old unsv complete all as specified and directed.Note 1:- Excavation and earth work, sand cushioning, protection covers protection pipes and jointing kits including jointing materials shall be measured and paid for separately. 9 Supply,laying testing cable XLPE insulated, screened PVC bedded, galvanised steel strip or wire armoured electric power cables (heavy duty) with aluminium conductor 11000 volts grade (Earthed) of size 185 sqmm 3 core including taking down old unsv complete all as specified and directed.Note:-HT Cable laying in existing trench at 33 KV MRS, Hence excavation and earth Work has not been required at existing in place of 33 KV MRS. 10 Inspecting, Servicing, testing and calibration of 33 KV SF 6/ VCB Breaker with control relay Panel as recommrnded by OEM by deploying expert inspector cum engineer and helper of authorised associates of M/s Cromptom Greaves Company.(a) Properly clean the VCB with a CRC-226 & ensure proper lubrication in VCB (Electrical contact cleaner).(b) Removal of old grease & regreasing the same with recommened grease.(c) Check condition of SIC contacts, alignment jaw contacts proper tightening of harware, proper closing of all poles together.(d) Check & adjust gap between hyleum sheet and side plate.(e) Cheks pressure of all circlips.(f)(i) Check IR between Phase-Phase (VCB closed condition). (ii) Phase-Earth (VCB closed condition). (iii) Phase -Earth (VCB in open condition).(g) Any faulty spares/parts to be replaced with new one.Note:-Necssary certificate of clabration to be submitted by the contractor. 11 Supply and fixing of Neumerical Relay for OC/EF, 110V DC for 33 KV/11 KV CR panel as recommended by OEM by deploying expert inspector cum engineer and helper of authorised associates dealer complete all aspecified and directed.Cat part No: TCS CG114S 12 Supply and ficing of Spring charging AC Motor for indoor 11/33 KV CR/VCB Panel as per existing in place recommended by OEM by deploying expert inspector cum engineer and helper of authorised associates dealer complete all aspecified and directed.DELCO 13 Supply and fixing of Digital Multifunction Meter for 11/33 KV CR/VCB Panel as per existing in place recommended by OEM by deploying expert inspector cum engineer and helper of authorised associatesdealer complete all aspecified and directed.Make: Secure Elite 445 14 Supply and fixing of Digital Voltmeter/Ammeter for 11/33 KV CR/VCB Panel as per eixsting in place recommended by OEM by deploying expert inspector cum engineer and helper of authorised associates dealer complete all aspecified and directed.Make secure 15 Supply and fixing of LED Indicator bulb for 11-33 KV CR/VCB panel as per existing in place of any color i.e Red, Yellow, Blue, Green and white recommended by OEM by deploying expert insector cum engineer and helper of authorised associated dealer completeall aspecified and directed. Make 2 JVS Semeplorp 16 Supply & fix in repair porcelain vitreous HT 11 KV bushings with brass studs suitable for out door distribution transformers of capacity 63 KVA-300 after removing the old u/s studs/bushings and draining out the transformer oil from the top level up to conservator of the transformer and removing the top cover of the carefully and refixing and refilling the oil complete all as specified and as directed. 17 All same as Per item No 16.00 here in before but LT bushings.Note:-For item No 16.00 and 17.00 The Transformer Repair/Servicing works shall be carried out only by engaging specialized and experienced technicians. The rate shall be included making necessary arrangements to remove the oil in the conservator in safe drums and refilling after the repair works. 18 Excavation in trenches in soft/loose soil not exceeding 1.5 metre wide and not exceeding 1.5m in depth for laying of HT under ground cables. Complete all as specified and directed. 19 Returning filling in, including spreading, watering and well ramming in layers not exc 25 cm thick in layer, complete all as specified directed. 20 Removal of surplus soil to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point, complete all as specified and directed. 21 M&L for sand conshionig to trenches existing cable trenches for cushioing of HT underground cable including spreading levelling well ramming in lavers not exceeding 25CM in thickness complete all as specified and directed. 22 Supply and laying un-reinforced precast concrete cable cover laid flat dry laid perpendicular to the length of under ground cable in trenches for cable protection complete of class HV type 1 flat of size 300MM x 180mm x 40mm complete all specified and directed by Engineer in Charge. 23 S&F in repair, 11 KV, 200 Amps, outdoor, tilting type, gang operated, air break off laid disconnecting switch, triple pole, each consists of galvanized channel base HT insulator, non - ferrous knife and spring loaded contacts, arcing horn of adequate section of break magnetizing current of the transformer, horizontal GI pipe of adequate length for phase separation and for operation from ground level and operating handle, complete with locking arrangement on both ON and OFF position, all ferrous parts shall be hot dipped galvanized and non ferrous parts to withstand weather suitable for vertical mounting and conforming to IS 1818-1961, complete all as specified and as directed. 24 S&F in repair lightening arrester, non-linear metal oxide type, complete with and including all fittings, transmission/ distribution class, discharge capacity 65 Kilo amps suitable for 11 KV, outdoor type and also including necessary connection fittings all as per IS-3070 Part-III and IEC 1994, complete all as specified and as directed. 25 S&F in repair, for HT drop out fuse unit suitable for 200 A capacity, 11KV, (Two post insulators per pole) with and including HT barrel fuse with holder and also including necessary connection ACSR conductors, complete all as specified and directed. 26 Dismantling of Over head aluminium conductor steel reinforced, complete all as specified and directed. 27 M&L for Over head aluminium conductor steel reinforced of size as per existing for making connections to CTs, PTs, GODs and Droup out fuses, complete all as specified and directed. 28 Dismantling of cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, complete all as specified and directed. 29 M&L for cross arms, bracing, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of preparation of exposed surfaces, application of one coat of red oxide primer and thereafter 2 coats of alluminiuam paint, complete all as specified and directed. 30 S&F Pin type, procelain, vitreous, white, brown or green insulator including one galvnished mild steel spindle, two galvanised iron washers and one galvanied iron nut, 150mm dia, for 11 KV grade including taking down, complete all as specified and directed. 31 M&L for cement concrete type B2(1:2:4) (using 40mm graded stone aggrgate) for pole foundation and copeing including provision of necessary form work, complete all as specified and directed. 32 M&L Hardcore of gauge n.exc 63mm with broken stone or boulders, deposited, spread and levelled in layers n.exc 15cm thick, watered and rammed to a true surface. 33 Surface dressing in hard / dense soil / aggregate not execeeding 15Cmdeep and clearing all the grass weeds etc in the 2/4 pole structures GODs and various unmanned No of sub station and including other E/M installation as directed after removing and spreading back the aggreagated by doing twice a month upto the completion of CA in each sub station and E/M installation as directed by Engr-in-Charge. 34 Material and labour for Danger notice plate 1.6 mm thick mild steel vitreous enameled white with letters, figures and conventional skull and bones in signal red colour and fixed with MS clamps bolts and nut etc.Complete of size 25 x 20 cm for HT 11000 volts complete all as specified and as directed incl. taking out old UNSV notice plate. 35 Material and labour for Danger notice plate 1.6 mm thick mild steel vitreous enameled white with letters, figures and conventional skull and bones in signal red colour and fixed with MS clamps bolts and nut etc.Complete of size 25 x 15 cm for LT 11000 volts complete all as specified and as directed incl. taking out old UNSV notice plate. 36 Material and labour for Anti Climbing device spikes type fabricated out of MS Bars (Round Square and flat) including nuts, bolts, washers and welding in two halves made to shape to suite the cross section of the pole complete all as specified and directed. 37 M & L for HT Cable route indicator with a welded / riveted disc of 4 inch dia and engraved with cable with cable route marker made out of angle iron 40 x 40 x 4 mm thick dug in ground with in and incl PCC 1:3:6 type C1 using 20mm graded aggregated at approx distance 100 mtr including necessary earth work complete all as specified and directed by Engr-in-Charge. 38 M&L earthing complete with galvanised steel earth plate electrode of size 600 x 600 x 6 mm thick buried directly in ground in vertical position (earth pit not less than 2.25 m deep below the normal ground level) with top edge of the earth plate not less than 1.5m below normal ground level, connected to galvanised earth lead of GI strip 32x6 mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel, all as shown in electrical plate No. 3 connected to earthing test point and including dismantling complete all as specified and directed. Note :- The unit rate shall also include for earth work in any type of soil, PCC 1:3:6 type C1 chamber, RCC 1:1.5:3, type A1 cover slab, 50mm thick reinforced with 8mm dia TMT bar @ 140mm C/C both ways, 10mm dia plain bar lifting handle embedded in cover slab, 20 mm bore medium grade GI watering pipe, 15mm bore GI light grade earth lead protection pipe, funnel, wire mesh, copper lugs, charcoal and common salt in alternate layer etc. 39 M&L earthing complete with copper earth plate electrode of size 600 x 600 x 3.15 mm thick buried directly in ground in vertical position (earth pit not less than 2.25 m deep below the normal ground level) with top edge of the earth plate not less than 1.5m below normal ground level, connected to copper earth lead of size 20x3 mm by means of bolts, nuts, check nuts and washers of copper, all as shown in electrical plate No. 3 connected to earthing test point and including dismantling complete all as specified and directed. Note :- The unit rate shall also include for earth work in any type of soil, PCC 1:3:6 type C1 chamber, RCC 1:1.5:3, type A1 cover slab, 50mm thick reinforced with 8mm dia TMT bar @ 140mm C/C both ways, 10mm dia plain bar lifting handle embedded in cover slab, 20 mm bore medium grade GI watering pipe, 15mm bore GI light grade earth lead protection pipe, funnel, wire mesh, copper lugs, charcoal and common salt in alternate layer etc. 40 Supply only transformer Oil conforming to IS-335 (make : POWER OIL/HP/BP/SAVITA TRANSOL) for toping up/oil change of Transformers of any capacity at different locations, complete all as specified and as directed.Note :- (i) The dielectric strenght of the transformer oil shall not be less than 55KV in 2.5mm gap electrode. (ii) Quoted rate shall also be deemed to include for testing of transformer oil from CPRI/ Govt approved lab as per relevant IS and submission of necessary test reports. 41 Vaccume dihydration with hot filteration plant of old transformer oil at different locations, after filteration, Di electric strength shall not be less than 55 KV in 2.5mm gap electrode, complete all as specified and as directed. The contractor shall submit necessary Test Report for Di electric strength before dehyderation as well as after dehyderatin from CPRI/ Govt. approved Lab as per relevant IS. The contractors quoted rates shall also be declared to include for this element. Note :- Transformer Oil after dehyderatin shall be measured and considered for the payment under the above item. 42 M&L for spray painting of 2.5 MVA capacity power transformers applyying one coat of synthetic enamel paint including preparing the old painted surfaces by removing the paint flakings from the transformer body surfaces complete all specified and as directed. 43 Material and labour for painting of Transformers outer body of capacity 100 to 150 KVA including cleaning / preparing the old painted surface before spray paint existing colour of transformer all as specified and directed. 44 Cutting / trimming of tree branches in close proximity to over head lines to maintain a clearance of 1.5 meters from the over head line to nearby trees complete all as specified and as directed.Note:-Only effected length of over head conductor (length of only one conductor for the effected area) shall be measured as per running meter for payment purpose. 45 S & F silica gel of superior qualityof 6 to 12mm grade, blue in coloure, complete all as specified and directed. 46 Material and labour for painting of 11m steel pole with cross Arms, Clamp of any length and shape for HT overhead line with two coat of aluminium paint including prepration of the existing surface including marking pole numbers in a 15cm dia yellow circle & marking three black & two yellow bands width 30 Cm by fluorescent paint, from bottom of pole to 1.5 Mtr height, complete all as specified and directed. 47 S & F for Current Transformer (CT) of cap 11KV Range 300-150/5-5A indoor complete all as specified and directed suitable for CG Panel
Contract Date: Mar 04, 2025 Contract Value : 15.78 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 3
37.
Defence #5500285 AOC
Provn Of 100 Kva Distribution Transformer And Allied Works For Simulator Building At Mil Stn Jaisalmer; Supply and Installation, testing and commissioing of outdoor type step down transformer 100 KVA, 11/0.433 KV, 3 Phase 50 Hz, ONAN Cooled Oil Immersed Copper woundcomplete with oil tank including first fill of ISI marked insulating oil up to top level, oil level indicater, breather with Silica gel, lifting hooks, drain valve, air vent valve, tackel wheel with channel and lockingarrangement to put on the plinth withexternalcooling tubes, Core type, delta connected on primary side (HV) and star connected on secondary side LV) in accodance with vector symbol DYN-11 (vector Group-4) with neutral brought out on secondary side (LV Side) OFF load tap Changer with mannual voltage regulation 0.433 KV in suitable steps/position on HVside to give output of 0.433 KV on LVside and provision of following accessories and connecting with electrical system, earthing etc. including all jointing materials,all as per IS 1180-2014 and energyefficiency level-II including filling of trasformer oil having confirming to IS : 335-1993 of dyelectric strength more than 50KV complete all as specified and directed by Engr-in-charge and shall comprise of the followingaccessories as per manufactures direction:- (a) 03 Nos porclain HT bushings with brass/gun metal bushingrods complete with nut and washers on primary(HV) side with arcing horn.(b)4 Nos porcelain bushings with brass/gun metal bushing rods complete with nut and washers on secondary(LV) side suitable for XLPE LT Cable (c)Oil conservator with filter typedrain valve and oillevel gauge oil filter hole with caps/plugs and breather assemby. 2 Item No. 1.00 Contd .....(d)De-hydrating breather with first fill dehydration agent (Silica gel).(e)Explosive vent. (f) Thermometer pocket on tank cover.(g) One No 100MM dia, dial type thermameter, vapour pressure type having range 0-120 degree celsius with metal guard having minimum perimeter reading temperature indicator with resistingdevice for transformer.(h) Two earthing terminals to be provided diagonally on either side of transformer body to facilitate fixing of 50x6 mm galvanised iron earth strip for body earthing.(j)Name plate and terminal marking .(k)Oil drain filter valve.(l)Lifting lugs.(m)Oil filling hole with cap/plug with conservative tank. (n)Four plain solid cast steel detachable rockters.(o)Provision of 2 Nos danger boards 250/200 mm size made out of 1.6 mm thick plate, viterous enamele white, with letters figures of voltageand conventional skall and benes insignal redcolours on frant side.The rear side of the plate also beenamelled. (p)Any other fittings/accessories so as to confirm the whole transformer to 1180 : 2014.(q)Off load changer of range (+) 7.5% to (-) 7.5% instep of 2.5% each, 7 steps. 3 Supply, Install, Testing & Commissioning self supporting outdoortype totally enclosed LT Panel board of suitable size, IP-65, compartmentalised design, dust and varmin proof of size 1000x900x600mmsuitable for 440 Volt 3 phase 4 wire system made out of 3.0mm thick CRCA sheet and built upon rigid frame work having front and rear hinged doors with neoprence rubber gasket including danger plate, earthing strip point and, ventilation louvers at the rear side, bottom detachable gland plate complete with suitable size of Zinc/Cromium plated and nuts, bolts ;and washers etc. The pannel shall be painted with two coats of red oxide primer and final finish of synthetic enmelledgray paint andincomming/outgoing cable holes at the bottom.The Panelshall be emmbeded with 50 x 5 mm MS Angle Iron frame and 30 cm above the normal ground level complete with PCC foundation (1:2:4 )type B2complete all as specified and directed by Engr-in-charge. Note: All Internal connection of MCCB from BUS Barmade By using Aluminium busbar of rated Capacity (a) Aluminium bas bar 400 amps - 04 Nos, supported with suitable size of heavy duty PVC stand lock with suitable sizeof brass nut, bolts and washer with heat shrinkable PVC sleeving.The bar shall be colour coded (red, yellow and blue) for three phases and black for neutral. (b) MCCB 250 amps, 415 volt, 35 KA Breaking capacity 4 pole duly connected to bus bar As in coming -01 Nos (From TR to Panel).OUTGOING :- (c) MCCB 160 amps, 415 volt, 36 KA Breaking capacity 4 pole duly connected to bus bar As in coming -03 Nos (d) Digital VAF Meter (e) LED Indicating lamp (set of three) - 01 Set.(f) Internal control wiring with 1100 volt grade 1.5 Sq.mm stranded copper cable as per colour coding for all connections with suitable size lugs as required and as specified. 4 Supply, Install, Testing & Commissioning self supporting outdoortype totally enclosed LT Panel board of suitable size, IP-65, compartmentalised design, dust and varmin proof ofsize1000x900x600mm suitable for 440 Volt 3 phase 4 wire system made out of 3.0mm thick CRCA sheet and built upon rigid frame work having front and rear hinged doors with neoprence rubber gasket including danger plate, earthing strip point and, ventilation louvers at the rear side, bottom detachable gland plate complete with suitable size of Zinc/Cromium plated and nuts, bolts ;and washers etc. The pannel shall be painted with two coats of red oxide primer and final finish of synthetic enmelledgray paint andincomming/outgoing cable holes at the bottom.The Panelshall be emmbeded with 50 x 5 mm MS Angle Iron frame and 30 cm above the normal ground level complete with PCC foundation (1:2:4 )type B2complete all as specified and directed by Engr-in-charge. Note: All Internal connection of MCCB from BUS Barmade By using Aluminium busbar of rated Capacity.(a) Aluminium bas bar 300 amps - 04 Nos, supported with suitable size of heavy duty PVC stand lock with suitable sizeof brass nut, bolts and washer with heat shrinkable PVC sleeving.The bar shall be colour coded (red, yellow and blue) for three phases and black for neutral.(b) MCCB 125 amps, 415 volt, 25 KA Breaking capacity 4 pole duly connected to bus bar As in coming -01 Nos (incoming (c) Change Over 200 Amps -01(d) MCCB 100 amps, 415 volt, 25 KA Breaking capacity 4 pole duly connected to bus bar-02 Nos (Outgoing). (e)Digital VAF Meter(f)LED Indicating lamp (set of three) - 01 Set. (g) Internal control wiring with 1100 volt grade 1.5 Sq.mm stranded copper cable as per colour coding for all connections with suitable size lugs as required and as specified. 5 M&L for switch air break gang operated triple pole mechanically operated,mounted on HT insulator (12 insulator type vertical type) and MS galvanised steel frame withn operated mechanism worked from ground level including operating rod for current rating up to 200 Amps 11000 volts complete with locking arrangement MS clamps,bolts and nuts and washers etc also including drop out explusion type of fuse barrels of required capacity to suit load at site including two coats of red oxide primer on MS work complete all as specified and directed by Engr-in-charge. Note :- Channel, cross arms, bracings etc shall be measured and paid separately 6 S&F lightning arrestor HT 11 KV 10 KA station class complete all as specified and directed by Engr-in-charge. 7 Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 11000 Volts grade with stranded aluminium conductor of size 95 sq mm 3 core complete all as specified and directed by Engr-in-charge. 8 Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 120 sq mm 3.5 core complete all as specified and directed by Engr-in-charge. 9 All as per item No. 7.00 here-in-before but size 35 Sqmm 3.5 core 10 All as per item No. 7.00 here-in-before but size 50 Sqmm 3.5 core 11 M&L for cutting the existing bituminous road / hard standing to size not exceeding 45cm wide and depth not less than 45cm for passing of UG cable through GI pipe and making good the disturbed surface filled with excavated material and top 200mm depth with plain cement concrete 1:3:6, type C1 using 20mm graded aggregate complete all as specified and directed by Engineer-in-Charge. 12 M&L for GI pipe light grade of dia 50 mm laying in road and along with poles for cable protection complete all as specified and directed by Engr-in-charge. 13 All as per item No. 11.00 here-in-before but size 80mm dia 14 M&L for bore earthing not less than 250 mm dia 16 feet deep filled with black soil up to 7 feet from bottom complete with galvanized iron pipe40 mm bore medium grade 3 meter long tapers at bottom & provided 12 mm holes (staggered) at 75 mm centre to centre up to 2.5 meter of length from bottom , burried directly in ground filled with 45 cm alternate layer of chemical magnisium sulphate, charcoal & salt up to ground levl connected to galvanized iron strip 32 x 6mm as earthing lead by means of bolt and nut, check nuts and washer of galvanized iron or steel including brazing workand 40mm dia light grade pipe for earth lead protection and testing on completion complete all as specified and directed by Engr-in-charge. 15 M&L for earthing complete with CPRI tested 50mm dia, pure copper earth electrode pipe of length 3000mm, pipe in copper strip Technology with NABL tested, RoHS compliant earth enhancement compound 50 Kg in each bore hole in tripod configuration (three numbers of 50mm dia pure copper electrode pipe) interconnectedwith copper strip of size 20x3.00 mm and connected by means of exothermic brazing & porected by GI pipe light grade 32mm bore andPCC (1:3:6) type C1 earth chamber & cast iron earth pit cover 300x300x3mm connecting to test point & testing on ground complete includingexcavation, earth work, boring in any type of soil strata & cleaning of site complete all as specified and directed.Note :- (i) Cost of copper strip 20x3.00 mm and 32mm dia GI pipe light grade required for interconnection of three numbers of pure copper 50mm dia earth electrode is deemed to be included in unit quoted rates.Copper strip of suitable size from earth pit to test point/equipment shall be measured and paid seperatel.(ii) Cost of earth work, boring, PCC earth pit, CI cover, testing of earth after completion, connecting and commissioning is deemed to be included in unit quoted rates. (iii) Marking & painting of earth pit with iron plate of suitable size is deemed to be included in unit quoted rates 16 Note Item No. 14.00 Contd…. (iv) The boring will take place for 3 meter depth & 350mm dia for three numbers of pure copper earth electrode pipe to form tripod configuration.Earth enhance compound to be filled around the earth electrode in 100mm dia in 3 layers of 1 mtr each by means of PVC pipe of 100mm dia as casing/formwork.The remaining volume of bore shall be filled with clay soil (available from vicinity) in 3 layers of 1 mtr each.The PVC pipe to be removed sinultaneously.The cost of all this is deemed to be included in the quoted rate. (v) Minimum distance between each earthing is not less than 3 running meter. (vi) Testing of earthing shall be conducted and result should be less than 1.00 Ohms 17 M&Lfor copper strip 20x3.15 mm with saddles and fixing screws etc. for roof conductors and down conductors above ground complete all as specified and directed by Engineer-in-Charge. 18 Supply, Installation, Testing and Commissioning of voltage stabilizer Auto/Manual operation three phase AC 50 HZ naturally oil cooled on load steapless indoor type and designed for input variation between 340V to 460V with output voltage stabilized at 415 volt with accuracy + 2.5% and speed of correction 8 volt per second and of capacity 100 KVA, rolling contact brentford type, suitable for balance/unbalanced load including filling of transformer oil conforming to IS-335/latest edition and consisting of manufacture standard fittings/fixtures complete all as specified and directed by Engineer-in-Charge. 19 S&F Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and including applying one primer coat, one under coat and one finishing coat of paint complete all as specified and directed by Engineer-in-Charge. 20 M&L Aluminium conductor, steel reinforced complete all as specified and directed by Engineer-in-Charge. 21 Supply, Jointing and testing outdoor type cable termination heat shrinkable joint kit 11 KV Unearthed grade suitable for size 50 Sqmm to 95 Sqmm 3 core 11 KV under ground XLPE cable complete all as specified and directed by Engineer-in-Charge. 22 Supply, Jointing and testing indoor type cable termination heat shrinkable joint kit 11 KV Unearthed grade suitable for size 95 Sqmm 3 core 11 KV under ground XLPE cablecomplete all as specified and directed by Engineer-in-Charge. 23 S&F Distribution board sheet metal enclosure double door, factory made , fixed flush with wall inside the niches for mounting MCBs, 240 VOLTS WITH 200 Amps rated bus bar with front openable cover , Single pole and netural , 12 way consumer unitcomplete all as specified and directed by Engineer-in-Charge. 24 S & F Distribution board, VTPN, 4 way, vertical type, double door, 415 volts as per IP -43 with provision for DPX 100 MCCB as incommer and SP/TP MCB as outgoing and electrically connecting up complete all as specified and directed by Engineer-in-Charge.Make :- Indoasian Cat No.811888 or equivalent make and model as approved by GE. 25 Supply and fix MCCBs,100 Amps, 25 KA, 4 pole with adjustable thermal & magnetic settings complete all as specified and directed by Engineer-in-Charge.Make : Legrand Cat part No 420055 or equivalent make and model as approved by GE. 26 S&FMCB TPN 63 Amp, 16KA braking capacity230/240 volt ACcomplete all as specified and directed by Engineer-in-Charge. 27 S&F MCBs SP, C curve, 6-32 amps, 10 KA, 240 volts complete all as specified and directed by Engineer-in-Charge. 28 S &F MCB SPN, C curve, 32 amps, 10 KA, 240 volts complete all as specified and directed by Engineer-in-Charge. Make : Legrand Cat No Cat No 408617 or equivalent make and model as approved by GE. 29 M&L for submain wiring with approved colour code/as per IS (Red,black & green for single phase) circuit with two single core PVC insulated cable with multistranded copper conductor of nominal cross sectional area of 6.00 Sqmm (FRLS) for phase and neutralin conduit pipe size 20 mm or aboveincluding one run of PVC insulated multistrandedcopper conductor nominal cross sectinal area of 6.00 Sqmm (FRLS) of continous earth wire green in colour complete all as specified and directed by Engineer-in-Charge.Note :- Two runsof 6.00 Sqmm cable & one run of 6.00 Sqmm cable as earth wire and one run of conduit shall be measured and paid as one unit length 30 M&L for submain wiring with approved colour code/as per IS (Red,black & green for single phase) circuit with two single core PVC insulated cable with multistranded copper conductor of nominal cross sectional area of 10.00 Sqmm (FRLS) for phase and neutralin conduit pipe size 20 mm or aboveincluding one run of PVC insulated multistrandedcopper conductor nominal cross sectinal area of 10.00 Sqmm (FRLS) of continous earth wire green in colour complete all as specified and directed by Engineer-in-Charge.Note :- Two runsof 10.00 Sqmm cable & one run of 10.00 Sqmm cable as earth wire and one run of conduit shall be measured and paid as one unit length 31 M&L for submain wiring with approved colour code/as per IS (Red,blue & yellowfor threephase)conduitcircuit with one black colour single core PVC insulated cable with multistranded copper conductor of nominal cross sectional area of 10.00 Sqmm (FRLS) for neutral in conduit pipe size 25 mm or above including onerun of PVC insulated multistrandedcopper conductor nominal cross sectinal area of 10.00 Sqmm (FRLS) of continous earth wire green in colour complete all as specified and directed by Engineer-in-Charge.Note :- four runs of 10.00 Sqmm cable & tworun of 10.00 Sqmm cable as earth wire and one run of conduit shall be measured and paid as one unit length 32 M&L for bore earthing not less than 250 mm dia 16 feet deep filled with black soil up to 7 feet from bottom complete with galvanized iron pipe40 mm bore medium grade 3 meter long tapers at bottom & provided 12 mm holes (staggered) at 75 mm centre to centre up to 2.5 meter of length from bottom , burried directly in ground filled with 45 cm alternate layer of chemical magnisium sulphate, charcoal & salt up to ground levl connected to galvanized iron wire 4mm dia as earthing lead up to Panel /DB BOX as per site requirement by means of bolt and nut, check nuts and washer of galvanized iron or steel including brazing workand 40mm dia light grade pipe for earth lead protection including test point terminalcover the earhing hole by PCC chamber and GI coverand testing on completion complete all as specified and directed by Engineer-in-Charge. 33 Excavating in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, laying of cable/pipe etc or for shafts, wells, cesspits, manholes, pier holes etc not exceeding 10 Sqm on plan and getting out in soft/ disintegrated rock complete all as specified and directed by Engineer-in-Charge. 34 Returning, filling in including spreading, leveling, watering and well ramming excavated soft/disintegrated rockin layers complete all as specified and directed by Engineer-in-Charge. 35 Removing excavated materials (Soft/Disintegrated rock)to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed by Engineer-in-Charge. 36 M&L for sand cushioning to under ground cable using sand and gently punning to cushioning to cable complete all as specified and directed by Engineer-in-Charge. 37 Supply & laying 40 to 50mm thick roughly hammer dressed Jodhpur stone patti cable cover 25cm to 30cm wide and n. exc 60cm long each laid dry abutting with each other with maximum gap between adjacent slabs n. exc 10mm complete all as specified and directed by Engineer-in-Charge.
Contract Date: Dec 23, 2024 Contract Value : 23.96 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 7
38.
Defence #3745419 AOC
Tender For Provision Of Vehicle Repair Shed Under Ge 862 Ews; 2 Construction of block of Veh repair shed, complete all as specified and shown in drawings. 3 TotalAmount of Sch A Part - II (Site Clearance) 4 TotalAmount of Sch A -III (Internal Water Supply) 5 TotalAmount of Sch A -IV (Internal Electric Supply) 6 TotalAmount of Sch A -V (Plumbing Work) 7 TotalAmount of Sch A -VI (Area Drainage Work) 8 TotalAmount of Sch A Part -VII (Sewage Disposal Work) 9 TotalAmount of Sch A Part -VIII (Road, Path and Culvert) 10 TotalAmount of Sch A Part -IX (External Water Supply) 11 TotalAmount of Sch A Part -X (External Electric Supply) 12 TotalAmount of Sch A Part -XI (Retaining Wall) 13 TotalAmount of Sch A Part XII (Ramp and Washing Platform Work) 14 Sch A Part - XIII (Misc Items of Work) Note : This Schedule is not Pre-Priced by MES and the Pre-Priced rate indicated as Rs. 0.00 under col.5 signifies this fact only. 15 Construction of 30 user conventional LLDPE septic tank, design to carry sewage and sullage water, excavation in any type of soil PCC (1:4:8) below foundation, vent shaft, connection etc, complete all as specified and directed. 16 Construction of Soakage well (Brick construction) of size 2.4 mtr dia 3.00 mtr deep including excavation & earth work in any type of soil, PCC 1:3:6 type C-2 (using 40mm graded crushed stone aggregate) as in foundation, walls with brick masonry with top ring of M-25 (Design mix) concrete including intercepting chamber and screen chamber and solid brick work in cement mortar 1:4, RCC cover slab in M-25 (Design mix) concrete, filling with brick bats, interconnecting pipe of RCC/DWC complete all as specified and shown on drawing. 17 Supply, installation and testing of hi wall split units indoor/outdoor complete with cordless remote control unit and with in built heating and cooling arrangement and digital inverter twin rotary of capacity 2 TR, 3 star rated including copper tubing/pipes of suitable size and cable etc; complete all as specified and as directed. 18 Supply, installation and testing of hi wall split units indoor/outdoor complete with cordless remote control unit and with in built heating and cooling arrangement and digital inverter twin rotary of capacity 1.5 TR, 3 star rated including copper tubing/pipes of suitable size and cable etc; complete all as specified and as directed. 19 Voltage stabilizer for automatic operation, single phase naturally air cooled indoor wall mounted type & designed for input variation between 160 volts to 280 volts with output stabilized voltage at 230 volts with accuracy of ± 2.5% and of capacity 5 KVA, complete all as specified and directed. 20 Voltage stabilizer for automatic operation, single phase naturally air cooled indoor wall mounted type & designed for input variation between 160 volts to 280 volts with output stabilized voltage at 230 volts with accuracy of ± 2.5% and of capacity 4 KVA, complete all as specified and directed. 21 Sub main wiring with two run of single core FRLSHPVC insulated unsheathed 1100 volts grade cable with stranded copper conductor of size 4 Sqmm drawing through and includingconcealed rigid non metallic PVC conduit medium grade (ISI marked) 20mm dia or above as required including one single core FRLSH PVC insulated unsheathed 1100 volts grade cable with stranded copper conductor of size 4 sqmmas earth continuity conductorconnected to commen earth and earth dolly complete all as specified and directed. 22 Modular AC MCB box protected socket PVC plastic base 3 module including module MCB 20 Amps complete all as specified and directed. 23 FRP looping box of size (325x320x150)mm with connector and comprising of MCB SP 6 Amps, ISI marked, 240V complete with and including providing GI clamps , nuts etc suitable for fixing on PCC pole/wall/steel tubular pole etc complete all as specified and directed.Make: National/Sintex. 24 GI bracket pipe of size 40mm dia medium grade of 1.2mtr long, bent to shape,suitable for street light fitting and making the one end of GI pipe bracket suitable for fixing of street light fittings of any type and the GI bracket pipe shall be fixed on wall /pole, steel/PCC surfaces by providing suitable MS iron 25x4 mm clamps 2 Nos of length as required at site to the bracket pipe and painting to MS clamps and fixing with necessary suitable nuts, bolts & washers, complete all as specified and directed. 25 Copper conductor cable,1.5 Sqmm, 3 core,PVC insulated, FRLSH sheathed flexible, multistranded, ISI marked, 1100 Volts grade including necessaryconnection and testing, complete all as specified and directed. 26 Supply, installation, testing and commissioning of totally enclosed LT electric panel outdoor type IP-65/66fabricated out of 3.15mm thick CRCA, CPRI approved sheet dust and vermin proof powder coated double door type independent cabin including locking arrangement for each MCCB, bus bar chamber with inner shell, thickness of panel 2.0mm complete suitable for operating on 415 volt 50 Hz AC supply internally wired with copper conductor/strip of adequate size from main incoming MCCB to bus bar and bus bar to outgoing MCCBs, LT panel having legs 45cm made out of 65x65x6mm angle iron grouted on brick masonry platform upto 30cm. Brick masonry platform should be 60cm above the ground level, comprising the following:-(a) MCCB 250 Amps, FP, 36 KA, 415 volts, 50Hz -01 No (Incoming)(b) MCCB 125 Amps, FP, 16 KA, 415 volts 50Hz -02 Nos (Outcoming)(c) MCB 63 Amps, SPN, 10 KA, 230 volts 50Hz -02 Nos(d) Digital voltmeter, with VSS -01 set , Digital, Ammeter, with CTs, & ASS-01 set (e) LED phase indication lamps RYB -01 set (f) Aluminium bus bar TPN 400 Amps rating -01 set 27 Earthing complete with galvanised steel earth plate electrode 600mmx600mmx6mm thick buried directed in ground (earth plate not less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.5m below normal ground level) connected to and including galvanised strip 32x6mm by means of bolts, nuts, check nuts and washers of galvanised iron including PCC 1:2:4 in pit, angle iron 25x25x3mm frame work with precast RCC 1:2:4 cover reinforced with 8mm dia TMT bars @ 150mm C/C both ways and 12 mm dia MS fabricated handle, mediumgrade GI watering pipe 20mm bore with funnel, wire mesh and light grade GI protection pipe 40mm bore upto 7.5m length for drawing in earth lead wire, salt, charcoal, etc. Including excavation and earth work in any type of soil, removal of surplus soil to a distance not exc. 50m complete all as shown in electrical plate No 3 of MES schedule 2009 (Pt-I) and connected to main control board all as specified or indicated including testing on completion, complete all as specified and as directed. 28 Point wiring complete with 1.5 sqmm PVC insulated, FRLSHtype, unsheathed, multistranded, flexible copper conductor cable 1.5 Sqmm 1100 volts grade, drawn through and including concealed PVC conduit, medium grade of size 25mm or above as required at site with all accessories such as tee, corner, overlaping connector etc; on surface walls, roots and ceiling etc; including modular steel terminal boxes of required size alongwith modular white cover plate with frame for mounting modular switches, socket, fan regulators etc; and including 1.5 Sqmm PVC insulated, multistranded, unsheathed (greed colour), FRLSH type single core, copper conductor cable as earth continuity conductor and connecting to common earth dolly for one light point controlled by one switch, complete all as specified and directed 29 All as per Srl Item No. 27 hereinabove but for one 3 pin 6 amps socket outlet point controlled by one 6 amps switch on independent board. 30 All as per Srl Item No. 27 hereinabove but for one 3 pin 6 amps socket point controlled by one 6 amps switch on same board. 31 All as per srl item No. 27here-in-before but one light point controlled by 2 way 6 amps switch. 32 All as per Srl item No.27 hereinbefore, but point wiring with 2.5 sqmm copper conductor cable and earth conductor of size 2.5 sqmm copper conductor cablefor one 6 pin 16/6 amps socket outlet point controlled by one 16 amps switchon independent board complete all as specified and directed. 33 Point wiring complete with 1.5 sqmm PVC insulated, FRLSHtype, unsheathed, multistranded, flexible copper conductor cable 1.5 Sqmm 1100 volts grade drawn through and including concealed stove enamelled steel conduit of size 20mm or above as required at site with all accessories such as tee, corner, overlaping connector etc; on surface walls, roots and ceiling etc; including modular steel boxes of required size alongwith modular white cover plate with frame for mounting modular switches and including 1.5 Sqmm PVC insulated, multistranded, unsheathed (greed colour), FRLSH type single core, copper conductor cable as earth continuity conductor and connecting to common earth dolly for flame proof fittings point controlled by one switch, complete all as specified and directed. 34 LED 70W high bay light energy saving, environment friendly & robust IP 65 protected LED midway with PDC housing suitable for ceiling (surface /suspended) mount & available wide beam optics, including connecting up with three core flexible copper conductor cable of suitable size from ceiling roseand overall sheathed flexible copper conductor cable of size 0.75 sqmm 3 core, complete all as specified and directed. 35 LED lights fitting 1x20W, 220V. AC type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose and overall sheathed flexible copper conductor cable of size 0.75 sqmm 3 core, complete all as specified and directed. 36 CRCA box type LED lights fitting including 2x20W LED tube polycarbonate, 220V. AC type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose and overall sheathed flexible copper conductor cable of size 0.75 sqmm 3 core, complete all as specified and directed. 37 Factory made sheet metal enclosure, double door, 415 volts, AC, TPN vertical distribution board 12 way painted with epoxy based powder coated suitable for mounting MCCB as incomer of rating upto 250 Amps, FP, rating upto 36 KA and MCB SP/TP as outgoing and complete with including 200 Amps rated copper busbar, neutral bar, each bar, connecting cable links with and including top bottom removable gland plate with IP 43 protection, completeall as specified and directed. Note:- MCCB/MCBs will be measured separately. 38 MCBTP 40 Amps, 10 KA, 415 Volts C series complete all as specified and directed. 39 MCCBFP adjustable type, 250 Amps, 36 KA, 415 Volts complete all as specified and directed. 40 Sub main wiring with two run of single core FRLSHPVC insulated unsheathed 1100 volts grade cable with stranded copper conductor of size 6 Sqmm drawing through and includingconcealed rigid non metallic PVC conduit medium grade (ISI marked) 20mm dia or above as required including one single core FRLSH PVC insulated unsheathed 1100 volts grade cable with stranded copper conductor of size 6.0 sqmmas earth continuity conductorconnected to commen earth and earth dolly complete all as specified and directed. 41 Sub main wiring with two run of single core FRLSHPVC insulated unsheathed 1100 volts grade cable with stranded copper conductor of size 2.5 Sqmm drawing through and includingconcealed rigid non metallic PVC conduit medium grade ISI marked 20mm dia or above as required including one single core FRLSH PVC insulated unsheathed 1100 volts grade cable with stranded copper conductor of size 2.5 sqmmas earth continuity conductorconnected to commen earth and earth dolly complete all as specified and directed. 42 Sub main wiring with two run of single core FRLSHPVC insulated unsheathed 1100 volts grade cable with stranded copper conductor of size 4 Sqmm drawing through and includingconcealed rigid non metallic PVC conduit medium grade ISI marked 20mm dia or above required including one single core FRLSH PVC insulated unsheathed 1100 volts grade cable with stranded copper conductor of size 4 sqmmas earth continuity conductorconnected to commen earth and earth dolly complete all as specified and directed. 43 Sub main wiring with four run of single core FRLSHPVC insulated unsheathed 1100 volts grade cable with stranded copper conductor of size 10 Sqmm drawing through and includingconcealed rigid non metallic PVC conduit medium grade ISI marked 20mm dia including one single core FRLSH PVC insulated unsheathed 1100 volts grade cable with stranded copper conductor of size 10 sqmmas earth continuity conductorconnected to commen earth and earth dolly complete all as specified and directed. 44 Earthing complete with steel earth plate electrode 60 cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 metres below normal ground level, connecting to the Galvanised iron earth wire 4.0mmdia by means of bolts, nuts, check nuts and washers of galvanised iron and steel earthwire protected by provision of GI Medium grade pipe 15 mm bore including provision of concrete pit made from PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) with 17mmthick cover of RCC (1:2:4) reinforced with XPM (weight not less than 4 Kg/Sqm) and frame of angle iron 25x3mm with lugs 02 No and with 6 mm dia MS bar handle made to shape GI medium grade 20 mm bore pipe for watering perforated at bottom, 1.75 metere long placed on top edge of earth plate, common salt and charcoal fittings, test point made out of 17 mm x 8 mm FI with fixing arrangement, funnel wire mesh and earth work in hard / dense soil, returning filling in and removal of surplus soil to a distance notexceeding 50m all as per electrical plate No 5 of SSR Part- I connected to earth test point complete all as specified and directed or indicated including testing on completion. 45 Supply, installation, testing and commissioning outdoor step down transformer 11000/433 Volts (at no load), AC 4 wire, 3 phase, 50 HZ of capacity 160 KVA, core type double copper wound, oil immersed, naturally cooled, oil natural, air natural (ONAN) with external cooling fans, delta connected on primary side (HV) and star connected on secondary side (LV) in accordance with vector symbal, DYN 11 (Vector group) with neutral brought out on secondary side (LV) and having tapping at 2.5% to 7.5% HV side to be changed by means of hand operated off load tap change gear, impedance@ 4.5% and losses at 50% load and full load and full load are 670 W and 1950 W respectively. The maximum temperature rise should not exceed 45 degree celsius in oil and 55 degree celsius in HV/LV winding when measured by resistance method after continuous full load run on an ambient temperature of 40 degree celsius. The transformer shall be IS: 1180-2014 Part-I (level-II) marked and shall comprises of the following:(a) 3 Nos porcelain bushing with arcing horn on HV side suitable for 11 KV complete with bushing, copper rods, nuts and washers.(b) One cable box on LT side (secondary side) consisting of four Nos. porcelain bushing with copper rod, complete with nuts and washers with 02 Nos. cable gland suitable for reception/taking out XLPE insulated heavy duly armoured cable including gland, joint and jointing material completed.(c) Oil conservator with filter type drain valve and oil level guage.(d) De-hydrating with first fill dehydrating agent (silica gel) 46 (e) Explosive vent.(f) Thermometer pocket on tank cover.(g) One No. 100mm dia, dial type thermometer, vapours pressure type, having range 0-120 degree, celsius with metal guard having maximumperimeter reading temperature indicator with resisting device transformer.(h) Two earthing terminals on tank cover to facilitate fixing of 32x6mm galvanized in earth strip for earthing of neutral & body.(j) Rating plate and terminal making plate.(k) Oil level gauge.(l) Oil drain/filter valve.(m) Lifting lugs.(n) Oil filling hole with cap/plug with connecting plate complete.(o) Air release valve plug.(p) Four plain solid cast steel detachable rollers.(q) Extra bushing for neutral, outside the LT cable box for providing independent earthing for neutral.(r) First filling of new and unused transformer oil conforming to IS-35/93 (fourth revision) marked (Make - savita/power oil or make as approved by the GE) filtered and tested up to 60 KV dielectric strength at 2.5mm air gap between testing.Note: Certificate of dielectric strength shall be submitted by the contractor after filling the oil. 47 Ceiling fan complete with three blades, down rod, electronic regulator and accessories, 230V, 1400mm sweep with brushless DC(BLDC) motor, 5 star rated including modular fan regulator, 120 watt, 2 module complete all as specified and directed. 48 Air circulator fan, 230 volts, single phase, oscillating 600mm sweep suitable for wall mounting with 3 speed low noise motor with strong air throw 12 cubic per feet high RPM 1400 vertical adjustment with corded electric, complete all as specified and directed 49 Construction of PCC platform for transformer of size 3.5m x3m and 1.2m high from ground level with brick construction walls and steps, PCC 1:5:10 type E-2 using 40mm graded crushed stone aggregate in foundation, brick work in CM 1:4, 10mm thick rendering in cement mortar (1:4), 50mm thick PCC 1:2:4 type B-1 using 20mm graded crushed stone aggregate in flooring and 40mm thick PCC on steps, painting to fencing with two coats of synthetic enamel paint over a coat of red oxide primer, including duly surrounded with XPM fencingcomplete with 40mm x 5mm angle iron post including MS gate made out of 40mm x 5mm angle iron & 12mm dia steel bar, fixed on PCC gate pillars complete with and including sliding bolts, locking arrangements, hinges and all accessories complete all as specified and as shown on drawings. 50 Deduction to be made from BOQfor Sch A Part-XIV (Schedule of credit) Amount of Rs.2,500.00 during AOC.Note: Tenderers shall not quote for this schedule.
Contract Date: Nov 30, 2024 Contract Value : 3.39 Crore
Statutory Bodies & Commissions/Committees No of Bidders 3
Jammu And Kashmir View Result →
39.
Defence #3745383 AOC
Tender For Repair/Maintenance Of Ht Under Ground Cables, God, 11Kv Ht Oh Lines, 2 Pole/4 Pole Structure And Connected Items At Various Substations At Yol Cantt- 1 Excavation in trenches, not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exceeding 10 Sqm on plan and not exceeding 1.5 mtr in depth and getting out inhard/dense soil, complete all as specified and directed. 2 All as per Srl Item No 1.00 above but depth exceeding 1.5 mtr and notexceeding 3.0 mtr. 3 Returning filling in (soil) including spreading, levelling, watering and well ramming in layers n.exc 25cms thick in any type of soil complete all as specified and directed. 4 Removing excavated materials/ soils, not exceeding 50mtrs and depositing where directed at a level not exceeding 1.50mtrs, complete all as specified and directed. 5 PCC 1:4:8 (nominal mix) type D-2(using 40mm graded crushed stone aggregates) as in foundation filling and mass concretecomplete all as specified and directed. 6 Plain cement concrete 1:2:4 ( nominal mix ) type B-1 (using20 mm graded crushed stone aggregates) as inin lintels upto 1.5m clear span, cills, steps; seismic and othersimilar ands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height,copings, kneelers, apex stones, bed plates, kerbs , water troughs and the like including weathering, slightly rounded or chamfered angles and throating,includingnecessary formwork where required complete all as specified and directed. 7 Sand cushioning to protection of underground cables, laid 8 Cm before laying and 15 Cm after laying of cable, and punned to form an overall layer of 18 Cms thick, complete all as specified and directed Note: Punned thickness shall be measured. 8 Sub class ‘B brick, old size, brick covering laid dry, flat, transversally along the length of cable on sand cushioning, with width equal to the length of the brick including taking out old bricks, complete all as specified and directed. 9 Supply and fixing of Male Contact / moving contact blade with arching horn having brass contacts suitable for 11 KVGOD, including galvanised iron bolts, nuts and washers for fixing on post insulator or any other indicated situationall as required at site or directed by Engr In charge. Make: Jaipuria brothers/Rashtriya/BHEL 10 Supply and fixing of Female contact spring loaded having brass contacts suitable for 11 KV GOD, including galvanised iron bolts, nuts and washers for fixing on post insulator or any other indicated situationall as required at site or directed by Engr In charge. Make : Jaipuria brothers/Rashtriya/BHEL 11 Mild steel galvanised iron tubing light grade for cable protection as in road crossing, along poles, walls, floors, drain of 80mm size fixed with MS clamps, nuts and bolts as required includingcutting of road or hardstandingby manual complete all as specified and directed. 12 Supply, jointing, fixing or passing through pipe, trenches or ducts, commissioning and testingXLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured,electric power cables (Heavy duty) with aluminium conductor, 11000 Volts grade, cross sectional area 95Sqmm, 3 core, suitable for 11 KV earthed system confirming to IS 7098 Part-2 for insulation and for conductors Class 2 to IS 8130-84, in trenches, floors, ducts passing through pipe for road crossing etc,including connecting & testing and disconnecting and taking down of old unserviceable HT cable complete all as specified and directed.(Note : Excavation, earth work, brick protection, sand cushioning and GI pipe etc shall be measured &paid for separately). 13 Supply, jointing, fixing or passing through pipe, trenches or ducts, commissioning and testingXLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured,electric power cables (Heavy duty) with aluminium conductor, 11000 Volts grade, cross sectional area 120Sqmm, 3 core, suitable for 11 KV earthed system confirming to IS 7098 Part-2 for insulation and for conductors Class 2 to IS 8130-84, in trenches, floors, ducts passing through pipe for road crossing etc,including connecting & testing and disconnecting and taking down of old unserviceable HT cable complete all as specified and directed.(Note : Excavation, earth work, brick protection, sand cushioning and GI pipe etc shall be measured &paid for separately). 14 Material and labour for detection of any type of fault in HT underground Line (laid in soil at plane area or forest area) with the help of Cable fault locator machine. Cable fault locator with carring vehicle will be brought by the cable fault detection agencies. faulty cable will be trace out by the agencies by meggering HT cable. 15 Renewal of cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination, heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm with suitable clamps made out of flat iron 50X6mm including nuts, bolts and washers, complete all as specified. 16 Renewal of cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination, heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm with suitable clamps made out of flat iron 50X6mm including nuts, bolts and washers, complete all as specified. 17 Renewal of cable jointing kit for 11 KV (Earthed) grade cable for straight through, heat shrinkable type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm, complete all as specified. 18 Renewal of pin type insulator porcelain, vitreous, white/brown or green including one galvanized mild steel spindle, two galvanized iron washers and one galvanized iron nut, 150mm dia and 150mm height for working pressure 11000 volts grade includng taking down existing insulators and removing from site,complete all as specified. 19 Supply, installation, testing and commissioning gang operated air break off load connecting switch HT, 11KV, tripple pole, each plate consisting galvanised steel base, verticle type mounted on 15 Nos post insulators and steel frame, non ferrous knife and spring loaded contacts, arcing horns complete with dropout fuse element assembly, operating rod of GI pipe, medium grade, 20 mm dia (without joint) of suitable size and locking arrangement, connections, mild steel frame with PG clamps and sleeves etc required for current rating 200 amps capacity including taking down unservicable GOD of any type, shape& size with steel frame and removing from site all as specified and directed. 20 Steel tubular swaged poles complete with base plate 8mm thick welded with pole, finial taper plug, bolt, nut and screws as specified type 410 SP-55 (11m long) including one coat of red-oxide zinc chrome primer and two coats of aluminium paint on surfaces exposed to view and making 30cm wide strips (total 5 Nos) with yellow and black paint alternately on external surface above PCC benching including numbering with black paint and painting with bituminous paint internally complete and externally for portion embedded in PCC including dismantling of old type of poles any length, complete all as specified and directed. Note:- Earth work & excavation and PCC shall be measured and paid under respective Items of BOQ. 21 Structural steel work as in cross arms, bracings, supports, clamp and back plate fabricated from steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed by Engineer-in-Charge and applying two coats of aluminium paint over one coat of red oxide zinc chrome primer including preparation of surfaces and dismantling old structural steel work in cross arms and stacking at site, complete all as specified & directed. 22 Renewal of disc type insulator, porcelain, vitreous 145mm high and 255mm dia ball and socket type, white, brown or green, Two-in-series assembly for tension with tension clamps for conductors working pressure 11000 Volts complete all as specified and directed. 23 Cleaning of installation area from inside and outside by removing the vegetation, cleaning the fungus formation and nearby growth of wild vegetation, bushes to a distance of 50 metres completeall as specified and directed. 24 Cutting of roadfor laying of cable through pipe and making good the disturbed surface by using cement concrete 1:2:4 type B-0, using 12.50graded crushed stone aggregate as required complete all as directed. 25 Cable route indicator made out of 2 mm thick mild steel sheet of size 20 cms X 15 cms duly coated with two coats of black paint over a coat of red oxide primer duly written the size of LT/ HT cable in white paint and welded to equal angle of size 30X30X3mm, 45 cms long and errected in ground in such a way that it is 15 cms above ground level and 30 cms below ground level. The portion below ground level should be embedded in plain cement concrete M-15, type B-I, using 20 mm graded crushed stone aggregate of size 15 cms X 20 cms X 45 cms all as specified & directed. Note:- Cost of PCC and earth work & excavation shall be deemed to be included in unit rate quoted by contractor. 26 Handle suitable for GOD operation, fixed in repair, complete all as specified. 27 Unbinding from insulators ACSR conductor any size of HT over head line for repairs, restretching of ACSR conductor to achieve proper sag and rewinding to the insulators using aluminium/ GI wire all as required at site or directed. Note:- Distance between two poles irrespective of distance and no of lengths of conductor shall be considered as a single span. 28 M & L in replacement for Earth continuity conductor or main earthing lead fixed to walls on batten or recess or chases or buried in ground or drawn in conduit/pipes or fixed to poles or any other indicated situation for loop earthing etc as required 4mm dia galvanised iron wire all as specified. 29 Dismantling and taking down old UNSV HT Bus bar panel , Supply , installation ,testing & commissioning of totally enclosed modular type weldless bolted type form 1A feeder pillar outdoor( HT Bus bar panel ) IP55 fabricated out of 3.15 mm thick CRCA sheet dust and vermin proof powder coated including locking arrangement bus bar chamber enclosed complete suitable for operation on 11000 volts 50 Hz AC supply having legs 50cms made out of 50x50x6 mm angle iron grouted on brick masonary platform upto 30 cms height. Brick masonary platform should be 60 cms above the ground level comprising the following : (a) 50x10 sqmm cross section area conductive electrolyte grade 3 nos copper bus bar of length of 500 Amps with heat shrinkable sleeve duly colour coded. (b) Bakelite insulators having short circuit withstand capacity of 26.3 KA -01(Set of three) Note : (i) The Panel should be front operated with cable entry from the bottom with cable glands. The fault withstand capacity shall be 50 KA. Earth bus shall be part of the main feeder pillar . (ii) Width of feeder pillar box shall not be less than the 120 cm. (iii) Cost for construction of platform for panel of brick masonary work in CM 1:6 with foundation 1:4:8 type D2 including plaster work , PCC Coping 1:2:4 (40 cm thick stone aggregate ), deemed to be included in the item rate, No Extra payment will be made. 30 Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25 metre deep below normal ground level) with top edge of plate not less than 1.5 metre below ground level, connecting to galvanised iron wire 4.0mm dia (as earth lead wire), by means of bolt, nuts, check nuts and washer of galvanised and earth wire protected by provision of galvanised iron pipe light grade, 15mm bore including provn of concrete pit in PCC (1:2:4), type B-I using 20mm graded crushed stone aggregates with 40mm thick precast cover of size 550 mm X 550 mm X 75 mm of RCC (1:2:4), type B-I, reinforced with XPM (weight not less than 4 kg/ Sqm) and frame of angle iron 25x25x3mm with lugs 2 Nos and with 6mm dia mild steel bar handle made to shape, galvanised iron medium grade 20mm bore pipe for watering perforated at bottom 1.75 metre long placed on top edge of earth plate, common salt and charcoal filling, test point made out of phosphorous bronze with fixingarrangement, funnel, wire mesh and including earth work in any type of soil, returning filling in and removal of surplus soil to a distance not exceeding 50 metre, all as per electricalplate No. 3 of SSR 2009 Part-I and connection to earth test point all as specified and testing on completion. 31 Deduct Credit Amount as per Schedule of credit as details given on Srl Page No 22 of tender doucments.
Contract Date: Nov 14, 2024 Contract Value : 10.81 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 5
Himachal Pradesh View Result →
40.
Power #3319057 AOC
Erection Of Equipments, Transformer, Bus Stringing, Cable Laying Etc In Connection With The 2Nd Phase Renovation And Capacity Enhancement Of 110Kv Ais Substation Perumbavoor- 1 Erection Of 1 No. 110 / 66Kv Ct / Pt / Cvt / Cc / 220Kv Nct On The Already Erected Structure Of Above 1.5M Height After Opening Of Crates At The Place Of Storage, Leading To Site Carefully Keeping At Vertically Not Allowing Tilting From Vertical Position More Than The Specified Angles, Keeping Lines And Levels As Per The Direction Of The Departmental Officers, Including All Labour Charges, Hire Charges Of Tools& Tackles Etc. 2 Conveying To The Erection Site And Erecting Carefully 1 No. 33Kv Ct / Pt / 110Kv Nct On The Already Erected Structure After Opening Of Crates At The Place Of Storage Leading To Site Carefully Keeping At Vertically Not Allowing Tilting From Vertical Position More Than The Specified Angles, Keeping Lines And Levels As Per The Direction Of The Departmental Officers, Including All Labour Charges, Hire Charges Of Tools& Tackles Etc. 3 Erection Of 1 No. 11Kv Ct / Pt / 11Kv Nct On The Already Erected Structure After Opening Of Crates At The Place Of Storage Leading To Site Carefully Keeping At Vertically Not Allowing Tilting From Vertical Position More Than The Specified Angles, Keeping Lines And Levels As Per The Direction Of The Departmental Officers. 4 Erection Of 1 No. 110 / 66Kv La / Post Insulator On The Already Erected Structure After Opening Of Crates At The Place Of Storage Leading To Site Carefully, Keeping Lines And Levels As Per The Direction Of The Departmental Officers 5 Erection Of 1 No. 33Kv La / Post Insulator On The Already Erected Structure After Opening Of Crates At The Place Of Storage Leading To Site Carefully, Keeping Lines And Levels As Per The Direction Of The Departmental Officers. 6 Erection Of 1 No. 11Kv La ( Station Type ) / 11Kv Post Insulator On The Already Erected Structure After Opening Of Crates At The Place Of Storage Leading To Site Carefully, Keeping Lines And Levels As Per The Direction Of The Departmental Officers. 7 Unpacking Carefully And Leading One Set Of 3 Pole Eht110kv Circuit Breaker From The Place Of Storage, Including Support Structure , Mechanism Box Compressor, Pipe Lines Etc. To Site , Cleaning And Erecting On Foundation Using Suitable Lifting Tools, After Disassembling Necessary Parts If Required, To Lines And Levels And Assembling All The Parts , Connecting Mechanism Etc. In Complete Shape And Making Ready For Commissioning As Per The Direction Of Departmental Officers. 8 Erection Of One Set 110Kv Bus Isolator On The Already Erected Structure Including Opening Crates And Conveyance Of All Accessories From The Place Of Storage To The Place Of Erection To Lines And Levels, Erection Of Mechanism Box , Checking Operation And Aligning Properly, Including Cutting, Welding Etc.Complete As Per The Direction Of Departmental Officers. 9 Uncoiling, Paving Out, Stringing And Fixing Of Bus Bar Using Acsr Kundah / Moose Single Conductor For One Phase Of 66 / 110Kv Bus Of Span Up To 30M By Cutting The Conductor To Sufficient Length, Crimping Using Compressor / Bolting The Two Ends, Washing, Cleaning And Drying The Insulator Discs, Fixing The Conductors To The Yard Structure With Sufficient Tension Using String Of Insulators And Hardware Complete. At Both Ends, Fixing Of Arcing Hornes Including Transportation Of Materials From The Stockyard To The Site Under The Supervision And Direction Of Department Staff At Site. ( All Materials Will Be Supplied Departmentally At Free Of Cost ) . 10 Uncoiling, Paving Out, Stringing And Fixing Of Bus Bar Using Acsr Kundah / Moose Double Conductor For One Phase Of 110Kv Bus Of Span Up To 35M By Cutting The Conductor To Sufficient Length, Crimping Using Compressor / Bolting The Four Ends, Washing, Cleaning And Drying The Insulator Discs, Fixing The Conductors To The 110Kv Yard Structure With Sufficient Tension Using String Of Double / Single Tension Insulators And HardwareS Complete. At Four Ends, Fixing Of Arcing Hornesat Both Ends, Fixing Of Spacers Between Two Conductors At Regular Intervals As Specified By The Dept. Staff At Site, Including Transportation Of Materials From The Stockyard To The Site Under The Supervision And Direction Of Department Staff At Site. ( All Materials Will Be Supplied Departmentally At Free Of Cost ) . 11 Stringing And Fixing Earth Wire Of Size 7 / 9, 7 / 10 Or 7 / 3.15 Between Top Of The Columns And To Terminal Tower At 33 / 66 / 110 / 220Kv Substations With Compressed / Bolted Ends At Proper Tension Including Uncoiling And Cutting Of Conductor , Jumpering, Giving Earth Bond Connections By Drawing The End Of The Conductor Through The Columns, Jointing Where Ever Necessary Providing Back Stays At The Time Of Stringing Etc. As Per The Direction Of The Departmental Officers. 12 Providinginterconnection Between Equipments Using Acsr Moose / Kundah / Wolfsingle Conductor At Both Ends With Compressed / Bolted Ends Including Uncoiling And Cutting Of Conductor As Per The Direction Of Departmental Officers. 13 Providing Droppers And Connecting To Lines / Equipments Or Jumper Between Two Buses Without Suspension Insulators Using Acsr Moose / Kundah / Wolfsingle Conductor At Both Ends With Compressed / Bolted Ends Including Uncoiling And Cutting Of Conductor As Per The Direction Of Departmental Officers. ( For One Phase ) 14 Providing Interconnection Between Equipments Using Acsr Moose / Kundah / Wolfdouble Conductor At Both Ends With Compressed / Bolted Ends , Fixing Spacers At Regular Intervals As Directed, Including Uncoiling And Cutting Of Conductor As Per The Direction Of Departmental Officers. ( For One Phase ) 15 Providing Droppers And Connecting To Lines / Equipments Or Jumper Between Two Buses Without Suspension Insulators Using Acsr Moose / Kundah / Wolfdouble Conductor At Both Ends With Compressed / Bolted Ends , Fixing Spacers At Regular Intervals As Directed, Including Uncoiling And Cutting Of Conductor As Per The Direction Of Departmental Officers. ( For One Phase ) 16 Providing Droppers And Connecting To Lines / Equipments Or Jumper Between Two Buses With Necessary Suspension Insulators For 33Kv / 66Kv / 110Kv / 220Kv Using Acsr Moose / Kundah / Wolfsingle Conductor At Both Ends With Compressed / Bolted Ends Including Uncoiling And Cutting Of Conductor As Per The Direction Of Departmental Officers. ( For One Phase ) 17 Laying Of Departmentally Supplied Gi Strip / Copper Strip Of Suitable Sizeincluding Cleaning And Neatly Bending Of Strips , Cutting, Removing Of Metal / Earth In The Yard And Burying Earth Strip To The Required Depth Re-Doing The Yard Metalling As Per The Direction Of The Departmental Officers. 18 Welding One End Of The Bended Gi Strip Of Size 50X6mm With The Riser Of The Already Laid Earth Mat, Welding 150Mm In Length, 6Mm Thick On Both Sides & End Of The Strip & Other End Of The Strip With Yard Structure At 2 Points 50Mm Apart Each Welding Points Having 50Mm Length And 6Mm Thick On Both Sides & End Of The Strip Including The Charges For Connecting The Strip With Structure Using Bolted Joints As Per The Directions Of The Department Officers. Charges Includes Hire Charges Of Dc Arc Welding Set, Current Charges, Cost Of Low Hydrogen Content Dc Arc Welding Electrodes ( No.E7018 ) Cost Of Anti Corrosive Paint Etc. Complete. 19 Welding Overlapping Joints Of 50X6mm Gi Strip With 50Mm Long, 6Mm Thick Welding On All Three Sides After Doing 2 Nos. Bolted Joints At The Centre As Specified After Cleaning The Surface. Charges Includes Hire Charges Of Dc Arc Welding Set, Current Charges, Cost Of Low Hydrogen Content Dc Arc Welding Electrodes ( No.E7018 ) Cost Of Anti Corrosive Paint Etc. Complete. 20 Welding One End Of The Bended Gi Strip Of Size 50X6mm With The Riser Of The Already Laid Earth Mat, Welding Length Of 150Mm In Length, 6Mm Thick On Both Sides & End Of The Strip And Connecting Other End With Nuts & Bolts If Required As Per The Directions Of The Department Officers. Charges Includes Hire Charges Of Dc Arc Welding Set, Current Charges, Cost Of Low Hydrogen Content Dc Arc Welding Electrodes ( No.E7018 ) Cost Of Anti Corrosive Paint Etc. Complete. 21 Welding One End Of The Bended Gi Strip Of Size 50X6mm With The Structure With A Welding Length Of 50Mm In Length, 6Mm Thick On Both Sides & End Of The Strip And Connecting Other End With Nuts & Bolts If Requiredincluding Hire Charges Of Dc Arc Welding Set, Current Charges, Cost Of Low Hydrogen Content Dc Arc Welding Electrodes ( No.E7018 ) Cost Of Anti Corrosive Paint Etc. Complete. 22 Unpacking The Transformer / Feeder C&R Panels, 110V Battery Charger, Oltc Cubicle Lt Panel At The Place Of Storage Transporting To The Place Of Erection And Erecting After Providing Foundation Bolt Keeping To Lines And Levels As Per The Direction Of Departmental Officers. 23 Fixing Departmentally Supplied Marshalling Kiosk In The Existing Pt / Ct Structure By Making Suitable Fixing Arrangements Including Cutting , Welding, Drilling Holes Etc As Required. 24 Uncoiling 20 / 19 Core 2.5Sqmm, 12 Core 4 Sqmm Control Cable ( Armoured Or Un Armoured ) From Cable Drums Cutting To Required Length And Laying Through Trench / Pipe / Cable Tray Grouping The Same Neatly Using Cable Tie And Carefullyincluding For Providing Loop Wherever Necessary And Providing Cable Marker At Both Ends Of Cable As Per Direction Of Departmental Staff At Site. 25 Uncoiling 12 / 7 / 6 Core 2.5 Sq Mm Control Cable ( Armoured And Un Armoured ) From Cable Drums And Cutting To Required Length And Laying Through Trench / Pipe / Cable Tray Grouping The Same Neatly Using Cable Tie And Carefullyincluding For Providing Loops Wherever Necessary And Cable Marker, At Both Ends Of Cable As Per Direction Of Departmental Staff At Site. 26 Uncoiling 4 / 2 Core 2.5Sqmm Control Cable ( Armored Or Unarmored ) From Cable Drums And Cutting To Required Length And Laying Through Trench / Pipe / Cable Tray Neatly And Carefully Including For Providing Loops Wherever Necessaryand Cable Marker At Both Ends Of Cable As Per Direction Of Departmental Staff At Site. 27 Uncoiling 5 / 4 / 3 / 2 Core 4Sqmm Control Cable ( Armoured Or Un Armoured ) From Cable Drums And Laying Through Trench / Pipe / Cable Tray Neatly And Carefully Including For Providing Loops Wherever Necessaryand Cable Marker At Both Ends Of Cable As Per Direction Of Departmental Staff At Site. 28 Fixing All Type Of Terminal Connecting Strip With Terminal Connectors In The Marshalling Box Or Panel Boardwherever Necessary ( Terminal Connecting Strip Will Be Supplied Departmentally ) Charges Includes For Providing Necessary Suitable Hole Etc Complete As Per Direction Of Departmental Staff At Site. 29 Termination Of Cables In Panel By Using Cable Glands Of Fixing The Cable Rigidly By Any Means As Per Direction Of Departmental Staff At Site Charges Include For Providing Necessary Suitable Hole In The Gland Plate Etc. For 20 / 19 Core 2.5Sqmm Cable / 12 Core 4 Sqmm Cable ( Using Gland Of Size 28-32Mm ) 30 12 / 7 / 6 Core 2.5 Sqmm Cable ( Using Gland Of Size 25Mm ) 31 4 / 2 Core 2.5 Sq Mm Cable / 4 / 2 Core 4 Sq Mm Cable ( Using Gland Of Size 16-22Mm ) 32 Doing Termination Of All Sizes Of Pvc Insulated Copper Control Cable 2.5Mm², Pealing, Providing Number And Letter Ferrules In The Wire, Stripping Ends, Crimping With Suitable Lugs And Connecting To The Terminals In The Panel Board And Marshalling Kiosk Etc., Neatly And Carefully Including Cost Of Copper Sockets And Ferrules As Per The Direction Of Departmental Officers At Site. 33 Doing Termination Of All Sizes Of Pvc Insulated Copper Control Cable 4.0 Mm², Pealing, Providing Number And Letter Ferrules In The Wire, Stripping Ends, Crimping With Suitable Lugs And Connecting To The Terminals In The Panel Board And Marshalling Kiosk Etc., Using Cable Tieand Cable Tie Neatly And Carefully Including Cost Of Copper Sockets And Ferrules As Per The Direction Of Departmental Officers At Site. 34 Supplying Aluminium Cable Tags Punching Number And Alphabets Up To 7 Digits And Binding To Cable Using Copper Wire Including Cost Of All Materials As Per The Direction Of Board Officials At Site. 35 Making Of Cable Clamps Using 25X 3 Mmgi Strip ( Hot Dipped ) As Per No Of Cablesin Cable Tray Cutting And Holing To Required Length And For Fixing As Per The Direction Of Departmental Officers At Site Including Supply Of Suitable Nut And Bolts. 36 Doing Out Door / Indoor Cable Termination Of 1X500 Mm2 11Kv Xlpe Cable Very Carefully Observing Directions Of Manufactures And Departmental Staff Including Crimping Of Socket 37 Laying 1 X 500 Sq Mm Xlpe Cables In Trench Including Drawing Through Pipes Wherever Necessary. 38 Mounting One 1X500 Mm2 Xlpe Out Door Cable Termination Of Structures Very Carefully Without Causing Any Damaged To The Drilling Holes Wherever Necessary As Directed By The Departmental Officers 39 Laying Lt / Dc Cables In Trench Including Drawing Through Pipes Wherever Necessary. 40 Glanding Lt / Dc Cable Of Various Sizes After Removing Insulation, Armour Etc. And Making Necessary Holes On Gland Plates Numbering Cable Etc. Complete Including Supply Of Gland Numbering Plate Etc. 41 Fabrication Of Structures For Erecting Equipments. The Gi & Ms Angles Will Be Supplied Departmentally 42 Drilling Holes In Yard Structure 43 Cutting Of Steel Angle In Yard Structure Erection 44 Welding Charge For Welding On Iron Parts Using Arc Welding As Per Standards 45 Erection Of Yard Structures And Assembling Of Columns And Beams Using Bolt And Nut Including Punching Of Holes. 46 Assembling The 10 / 12.5 / 25 Mva, 110 / 11 Or 66 / 11Kv Transformer With All Accessories In Complete Shape And Filling Oil If Required Including Arresting The Movement Of The Transformer By Locking As Per The Direction Of The Departmental Officers. 47 Covering The Transformer With Tarpaulin Using Ropes, Bamboos Etc. 48 Turning And Shifting 6000 L / H Capacity Transformer Oil Filtering Plant Or Wheel Mounded 10000 / 15000 Litre. Oil Tank With All Accessories For A Distance Of 20Mto Road, Towingthe Machine With Department Lorry By The Use Of D-Shackle And Iron Ropes , Accompanying The Lorry Including Supervision Through Out The Journey Especially In Turnings To Avoid Falling Of Plant. Remove The Machine From The Lorry And Drags Up To 10M For Safe Storage Where Ever Required. 49 Loading The Empty Oil Tank Of Capacity 10000 / 15000 Ltr. From The Place Of Its Storage Using Wooden Blocks, Lever Etc. And Moving The Tank To A Distance Of 10M From Switch Yard Then Loading The Same To The Dept. Vehicle Using Chain Pulley Etc. Carefully Tying The Tank In Vehicle Accompanying The Vehicle, Removing Ties Andunloading The Tank Carefully By The Use Of Wooden Blocks Rails, Chain Pulley Etc. Again Moving The Tank To A Distance Of 50M, For Safe Storage. 50 Hot Oil Circulation After Draining Oil From Transformer, Evacuating The Transformer By Using Vacuum Pump After Providing Lt Connection To The Pump , Connecting The Hose To Transformer, Operating Carefully And Continuously For Attaining Sufficient Vacuum And Keeping In Vacuum For 24 Hours And Operating Filter Unit Carefully And Continuously For 24 Hours Except Halt Due To Poor Voltage And Trouble In Filter Plant Etc Complete As Per The Direction Of Dept. Officers. 51 Supplying, Laying And Jointing 160 Mm Nominal Dia Pvc Pipes ( 6 Kgf / Cm² ) And Specials Such As Tees, Bends, Elbows, And Check Nuts, Etc. Including Refilling The Trenches, Etc. ( For Providing Control Cable Connections ) 52 Replacing All Gasket With The Departmentally Supplied Gaskets After Removing Old Gaskets Including Supplying Of Materials Required Such As Sand Paper, Glue, New Teflon Washers For Cooling FinS Air Nuts, Acrolithic Sheet For Oil Gauge Etc. Including Cleaning Of All Accessories Which Are Dismantled. 53 Overhauling Of Oltc Of 110 / 33, 110 / 11, 66 / 33 Or 66 / 11Kv Transformers By Lifting Diverter Switch After Draining Oil Inside The Oltc Chamber , Cleaning The Contacts, Removing Sledges From The Tank, Refilling The Chamber With New Oil Supplied By The Board. 54 Loading Ofpower Transformers Of Weight 20T To 30T, Carefully And Safely By Jacking Upinch By Inch Using Rails Sleepers Etc. And Placing On The Tractor Trailer Safely, Positioning Correctly And Fastening With Steel Ropes Tightening Using Turn Buckles Etc. With Out Causing Damage To Transformer And Accessories As Per The Direction Of The Departmental Officer Observing All Safety Precautions And Make It Ready For Transporting ( Distance To Be Specified ) . 55 Turning The Transformer Of Weight 20T To 30T, Up To 90 Degree Using Required Tools Safely And Taking All Precautions As Per The Directions Of The Departmental Officers ( Only If It Is Absolutely Necessary And Where Departmental Crane Is Not Available ) 56 Unloadingthe Power Transformers Of Weight 20T To 30T, Carefully And Safely Inch By Inch Inserting Railsand Trawling To The Platform Made With Sleepers And Thus Lowering Very Carefully Inch By Inch For Placing On The Rail Track And Hoisting To The Plinth With Out Causing Damage To Transformer And Accessories As Per The Direction Of The Departmental Officer Observing All Safety Precautions. 57 Pulling The Power Transformers Of Weight 20T To 30T, On The Rail Track, Travelling For A Distance Up To 30M, Using Sleepers, Rails, Jacking, Pulling And Keeping Ready For Placing On The Correct Plinth As Per The Direction Of Departmental Officers At Site, Safely Without Damaging Any Equipments And Observing All Safety Precautions. 58 Loading To The Department Lorry The Accessories Of 10 / 12.5 / 20 Mva Transformer Such As Bushings With Proper Package, Coolers, Conservator Tank, Connecting Pipes, Bolt And Nuts, Wheels, Rollers, Fans, Driving Mechanism, Cooler Control Box And Oil Drums Etc. Safely Fastening Them Properly, Accompanying The Vehiclewith Transformer From 110Kv Substation Angamaly / Any Other Place To 110Kv Substation Perumbavoor And Unloading And Stacking In Convenient Place, Taking All Safety Precautions As Per The Direction Of Departmental Officers. 59 Oil Draining Using 5000Lph Capacity Oil Filtering Plant After Placing The Filtering Plant In A Suitable Place Near To The Transformer And Empty Tank. Operating The Plant And Filling The Old Oil In To Empty Oil Barrel And Shifting The Same To A Distance Up To 50M For Safe Storage From A10 / 12.5 / 20 Mva110 Or 66 / 11Kv Transformer. 60 Dismantling The Accessories Of Transformer Such As Eht And Ht Bushings, Conservator Tank, Connecting Pipes, Bucholtz Relay, Radiator Etc. Using The Required Tools And Leading The Same For Safe Storage Of 20Mva Transformer. 61 Re-Assembling Of All Accessories Like Hv & Lv Bushings, Conservator Tank, All Pipelines, Cooling Fins Valves And Relays Etc Of 20Mva Transformer. 62 Filling The Oil In To 10000-15000 Ltr. Capacity Tank After Bringing The New Oil Barrel From Its Place Of Storage And Circulating The Same To Obtain The Necessary Value. 63 Connecting Vacuum Pump And Creating Vacuum Pressure Up To -760 Hg / Mm And Keeping The Same For 24 Hours And Monitor The Same After Leading The Plant To Yard Including Connecting Equalising Connection For Oltc. 64 Filling The Filtered Oil Into The Main And Oltc Tank Then Conducting Hot Oil Circulation Till To Obtain A Satisfactory Value Of Megger And Bdv For The Oilincluding Collecting Of Sample And Taking Bdv In Each Interval, Taking Megger Reading Etc. And After Filtering Provide The Breather. 65 Laying 3 X 300 Sq Mm 33Kv Xlpe Cables In Trench Including Drawing Through Pipes Wherever Necessary. 66 Doing Out Door / Indoor Cable Termination Of 3X300 Mm233kv Xlpe Cable Very Carefully Observing Directions Of Manufactures And Departmental Staff Including Crimping Of Socket. 67 Mounting One 3X300 Mm2 Xlpe Out Door Cable Termination Of Structures Very Carefully Without Causing Any Damaged To The Drilling Holes Wherever Necessary As Directed By The Departmental Officers
Contract Date: Mar 15, 2024 Contract Value : 12.66 Lakh
Boards / Undertakings / PSU No of Bidders 3
TenderDetail
Loading tenders