View Bid Results For Anti Rodent Work Tenders

We found 64 Bid Results related to anti rodent work tenders. You can find Contractor details who won anti rodent work tenders along with contract details in Bid awards announcements section.

Filters
Stage
50
8
6
Tender Publishing Platform
14
50
State / UT
17
10
9
8
6
5
4
4
4
3
2
2
2
1
1
1
1
1
Contract Value
16
13
21
14
Publish Date
0
0
0
0
0
Sector
13
16
9
7
7
6
5
3
3
3
2
1
1
1
Ownership
4
31
14
12
7
Within keyword
Active filters:
Showing 1–2 of 64 tenders matching your filters
1.
Public Administrative Department #11162234 AOC
Providing Fixing Various Equipments And Appliances, Cctv, Water Purifier Etc And Electrification Work In Zakir Hussain Hospital, Nmc-1 P / F Isi Mark Midget Type 3.0 Ltr Instant Type Water Heater Of Abs Plastic Body Kw, Heating Element 230 / 250 Volts 50 Cycle Ac Supply With Inlet And Outlet, Thermostatic Control And Thermal Cutoff With 3 Core Pvc Flexible Wire Leads Complete 2 P / F, Testing And Commissioning Of 1400 Va To 1600 Va Digital Pure Sine Wave Inverter Based On Insulated Gate Bipolar Transistor ( Igbt ) Technology Single Phase 230V, 50 Hz Complete As Per Specification No. Apinv ( Without Batteries ) 3 P / F Testing And Commissioning Of 2500 Va Digital Pure Sine Wave Inverter Based On Insulated Gate Bipolar Transistor ( Igbt ) Technology Single Phase 230V, 50 Hz Complete 4 P / F 12 V / 150Ah Battery With Battery Terminal Wire, Duly Charged Complete 5 P / F 12 V / 180Ah Battery With Battery Terminal Wire, Duly Charged Complete 6 P / F, Testing And Commissioning Split Type Variable Speed Inverter Technology Room Airconditioning Unit 1 Tr Having Iseer Minimum 4.50 Suitable To Operate On Capacity 250V, 50 Cycles, A.C. Supply Having 1 No. Of Air Handling Unit Hi-Wall Floor Mounting Type Complete With Refrigerant R410a / R32 And Copper Condenser At Position. 7 P / F Testing And Commissioning Split Type Variable Speed Inverter Technology Room Air Conditioning Unit 1.5 Tr Capacity Suitable To Operate On 250V, 50 Cycles, A.C.Supply Having 1 No Of Air Handling Unit Hiwall / Floor Mounting Type Complete. 8 P / F Testing And Commissioning Split Type Variable Speed Inverter Technology Room Air Conditioning Unit 2 Tr Capacity Suitable To Operate On 250V, 50 Cycles, A.C. Supply Having 1 No. Of Air Handling Unit Hi-Wall / Floor Mounting Type Complete 9 P / F Testing And Commissioning Of Etc Solar Water Heating System Without Heat Exchanger Type Of 500 Lpd Capacity Complete. 10 P / F Ultra Violet Storage Type Water Purifier ( Ro+Uv+Uf ) With Softener For Safe Drinking Water Consisting Of Uv Germicidal Tube Of 8W Capacity Choke Made Of Copper Wire And Two Indicator Lamps . 11 P / F 2 Mega Pixels Ip Dome Progressive Scan Image Sensor Camera With Awb / Agc / Blc Onvip 2.4 With Ip 66 Weather Proof Housing Supports Poe. 12 P / F 4 Channel Networking Video Recorder H. 264 .1080P, With One Vga & Hdmi Out, Resolution Ntc 1080P Pal 1080P Real Time Recording Sata Support Capacity 2Tb, 2Usb Port, Protocol- Tcp / Ip, Dhcp, Ddns, Upnp, Ntp & Smtp 13 P / F 8 Channel Networking Video Recorder H. 264 .1080P, With One Vga & Hdmi Out, Resolution Ntc 1080P Pal 1080P Real Time Recording Sata Support Capacity 4Tb, 2Usb Port, Protocol- Tcp / Ip, Dhcp, Ddns, Upnp, Ntp & Smtp 14 P / F 16 Channel Networking Video Recorder H. 264 .1080P, With One Vga & Hdmi Out, Resolution Ntc 1080P Pal 1080P Real Time Recording Sata Support Capacity 4Tb, 2Usb Port, Protocoltcp / Ip, Dhcp, Ddns, Upnp, Ntp & Smtp. 15 P / F Hard Disc Drive Of 4 Tb Capacity For Network Video Recorder 16 P / F 1Kva On Line Ups Pure Sine Wave With Standard Features, Along With Necessary Smf Batteries For 30 Mins. Battery Backup 17 P / F 2Kva On Line Ups Pure Sine Wave With Standard Features, Along With Necessary Smf Batteries For 30 Mins. Battery Backup 18 P / F 3Kva On Line Ups Pure Sine Wave With Standard Features, Along With Necessary Smf Batteries For 30 Mins. Battery Backup 19 P / F Testing And Commissioning 32 Hd Led Tv With 1366X768 Hd Ready- Great Picture Quality, 60 Hz : Standard Refresh Rate For Blur Free Picture Quality, Etc Complete 20 P / Laying Cat-6 Cable With Rodent Proof Suitable For Lan / Wan 21 P / F Testing Utp Connector ( Rj-45 ) 22 P / F And Configuring Broadband Router With All Accessories, On Provided Rack . 23 P / F And Configuring 8-Ports Managed Gigabit Switches Poe Smart Switch 24 P / F 6U Wall Mount Rack ( Dimension- Dxwxh – 450X550x367 Mm ) 25 P / Laying Hdmi Cable Low Voltage Grade As Per Specification As Per Specifications Having 5 Mtr Cord Length With Male / Female 19Pin Hdmi Connectors As Per Requirements Complete. . 26 P / F Testing And Commissioning Tata Sky Connection With 3 Month Recharge ( Tata Sky Connection 2100 / - + 3 Month Recharge ( Basic Marthi & Hindi Package ) 1050 / - 27 Recharge Of Set Top Box Connection ( Basic Marathi & Hindi Package ) 28 Recharge Of Broadband Connection 29 Making Plumbing Works On Terrace For 500 Lpd Solar Water Heating System Complete 30 Providing, Erecting Hand Dryer ( As Per Product Price Abs Hand Dryer ) 31 P / F Pvc Trunking ( Pvc Casing-N-Capping ) Of Size 25 Mm With Accessories On Wall / Ceiling . 32 Point Wiring In Pvc Trunking ( Casingcapping ) With ( 2+1E ) Copper Wire, Modular Type Switch, Earthing And Required Accessories 33 Point Wiring For Independent Plug In Pvc Trunking ( Casingcapping ) With ( 2+1E ) Frlsh Grade Copper Wire, Modular Type Switch, Earthing And Required Accessories . 34 P / F T8 Led 20W Tube Light Fitting ( 4 Feet ) With Aluminium Housing, Heat Sink, Integrated Hf Electronic Driver Complete . 35 P / F Centrifugal Mixer Domestic Type, Ss Container, Motor Suitable For 230 / 250 Volts Single Phase, 50 Cycles A.C. Supply Complete 36 P / F 3W, 230V Integral Type Led Lamp Suitable For B-22 / E-27 Base . 37 P / F 5W-7W, 230V Integral Type Led Lamp Suitable For B-22 / E-27 Base . 38 P / F Regular / Standard Model Ceiling Fan Complete Erected In Position 39 P / F Fan Clamp Of 30 X 5 Mm. M.S. Flat Of Required Length And 10 Mm. M.S. Bolt And Nuts Erected With Necessary Hook Of 10 Mm. M.S. Round Bar And Painted. 40 P / F ‘B’ Grade G.I. Pipe / M.S. Pipe Down Rod Duly Painted For Fan Complete Erected With Pvc Three Core Flexible Cable 1 Sq. Mm Copper Pvc Wire. 41 P / F Isi Mark Modular Type Electronic Step Regulator For Fan 42 Providing Aaa Batteries For Various Equipments As Required. 43 P / F Good Knight Machine For Mosquito Repellant Liquid. 44 P / F Refill For Good Knight Machine. 45 P / F Floor Cleaning Vaccum Cleaner Suitable For Operating On 240V / 50Hz Power Supply Complete. 46 P / F 3Kw Electrical Heater Coil With Anode, Thermostat, Auto Panel With Timer Etc Complete Suitable For 500 Ltr Solar Water Heating System Complete. 47 P / F Bracket Fan 400 Mm. Sweep A. C. 230 Volts 50 Cycles 1350 R.P.M. Oscillating Type, Plastic Or Metal Blades Chrome Plated Guard With Regulator And Moisture Proof Treatment To Winding And With ‘E’ Class Insulation 48 P / F 400Mm Pedestal Fan 230 Volts 50 Cycles Oscillating Type Complete With Guard Complete 49 Providing And Fixing 2 X 1.5Sq.Mm Mains With Copper Pvc Stranded / Solid Wire Complete 50 P / F 2 X 2.5Sq.Mm Mains With Copper Pvc Stranded / Solid Wire Complete 51 P / F 2 X 4Sq.Mm Mains With Copper Pvc Stranded / Solid Wire Complete 52 Providing And Fixing 2 X 6Sq.Mm Mains With Copper Pvc Stranded / Solid Wire Complete 53 P / F Isi Mark Modular Type Switch 6A 10A Duly Erected On Provided Plate And Box With Wiring Connections Complete 54 P / F Isi Mark Modular Type 3 Pin 6A Multi Sockets With Safety Shutter, Duly Erected On Provided Plate And Box With Wiring Connections Complete 55 P / F Isi Mark Modular Type 3 Pin 6 / 16A Multi Socket With Safety Shutter, Duly Erected On Provided Plate And Box With Wiring Connections Complete 56 P / F Isi Mark Modular Type Switch 16 / 20 A With Indicator, Duly Erected On Provided Plate And Box With Wiring Connections Complete 57 P / F Pvc Surface Modular Switch Box With Double Mounting Plate For 3 Modules Duly Erected 58 P / F Pvc Surface Modular Switch Box With Double Mounting Plate For 6 Modules Duly Erected 59 P / F Pvc Surface Modular Switch Box With Double Mounting & Front Plate For Modules Complete Duly Connected 60 P / F Pvc Surface Modular Switch Box With Double Mounting Plate For 12 Modules Duly Erected 61 P / F Double Pole Switch Surface Type / Flush Type 240V, 32A With Indicator Lamp & Fuse 62 Providing Fixing Marking Spmcb 6A To 32A, B- Series In Provided Distribution Board 63 Providing Fixing Marking Spmcb 40A To 63A C- Series In Provided Distribution Board 64 Providing Fixing Marking Dpmcb 6A To 32A, C- Series In Provided Distribution Board 65 Providing Fixing Marking Dpmcb 40A To 63A, C- Series In Provided Distribution Board 66 Providing Fixing Marking Tpmcb 6 A To 32A In Provided Distribution Board 67 Providing Fixing Marking Tpmcb 40A To 63A In Provided Distribution Board 68 Providing Fixing Marking Fpmcb 6 A To 32A In Provided Distribution Board 69 Providing Fixing Marking Fpmcb 40A To 63A In Provided Distribution Board 70 P / F Meter Box For Three Phase Energy Meter With Compartment For Mccb / Mcb Etc Complete. 71 Making Trench In Soft Soil For Laying Provided Cable . 72 P / F Single Door Refrigerator Domestic Type Of 270 Litres Storage Capacity, Suitable For Operation On 230 / 250 V, 50 Cycles Complete With Automatic Temperature Control Sealed Unit In Refrigeration System Complete. 73 P / F Two Option Coffee / Tea Vending Machine Operating On 50 Hz, 230 V Single Phase A.C. Supply. 74 P / F Three Option Vending Machine For Coffee / Tea Operating On 50 Hz, 230 V Single Phase A.C. Supply. 75 Providing Premix Of Tea / Coffee For Vending Machine Refillng. 76 P / F Single Door Refrigerator Domestic Type Of 215 Litres Storage Capacity, Suitable For Operation On 230 / 250 V, 50 Cycles Complete With Automatic Temperature Control Sealed Unit In Refrigeration System Complete. 77 Providing Evaporative Air Cooler 230 / 250 Volts, 50 Cycles, Normal Cooling Capacity Of 50 Cu.M Per Minute, With 12 Exhaust, Minimum 40 To 55 Litre Water Capacity Tank Complete. . 78 Providing Evaporative Air Cooler 230 / 250 Volts, 50 Cycles, Normal Cooling Capacity Of 60 To 70 Cu.M Per Minute With 15 Exhaust Fan, Minimum 68 Litre Water Capacity Tank Complete. . 79 Providing Evaporative 230 / 250 Volts, 50 Cycles, Normal Cooling Capacity Of 80 Cu.M Per Minute With 18 Exhaust Fan, Minimum 75 To 80 Litre Water Capacity Tank Complete. 80 Providing Basic Feature Mobile Set For Coordination Of Security And Building Coordinators / Ward Boys. 81 Making Plumbing Works For Fixing Instant Water Heater / Gryser / Water Purifier Using Various Aacessories Like Pipes, Valves, Tapes Etc Complete. 82 Making Plumbing Works For Fixing Storage Water Heater / Gryser Using Various Aacessories Like Pipes, Valves, Tapes Etc Complete. 83 P / Pasting Superior Quality Sun Control Film On Glass To Achieve Better Cooling Effect 84 P / Laying Telephone Black / Amba White Cadburybrown / Ruby Red / Ocean Brown Granite Stone Of 18 To 20 Mm Thick For Door Frame / Dado / Window Boxing Etc. On C.M. 1:6 Including Filling Joints With Polymer Base Filler Nosing / Moulding 85 Providing, Constructing Plinth For Substation Compound Required Excavation, Pcc In 1:2:4, 0.5Mtr Wide, 0.5Mtr Below And 0.5Mtr Above Ground In Cement Morter 1:6, Etc Complete As Per Rate Analysis. 86 P / F Fencing Of Section Having Size 2450 Mm In Height From Ground Level And 1200 Mm Width With Angle Iron Frame Work Complete 87 P / F Double Leaf Hinged Door Each 1500 Mm In Width X 1850 Mm In Height Using B Class, Gi Pipe With Angle Iron Supports, Chain Link Wire Meshcomplete 88 P / F 50 X 50 X 6Mm Angle Iron Corner Support 0.5M Away From Fence Support Fixed Etc. 89 P / F Gi Sheet 0.6 Mm ( 24 Swg ) To Be Used For Fabrication Of Boxes Panel Boards Etc. Including Cutting, Bending, Drilling, Welding, Riveting Etc. Complete . 90 P / F Marine Plywood 18 / 19 Mm Thick Fixed To Wall Or On Provided Panel Board With Necessary Materials Such As Screws, Wall Fasteners, Supports, Nut Bolts Etc. Complete. 91 Making Fabrication Work Using 16 Gauge Metal Sheet With Bending, Cutting, Drilling And Welding Complete . 92 Powder Coating In Siemens Gray Colour . 93 Making Iron Work For Fabrication With Bending, Cutting, Drilling And Welding Complete . 94 Providing And Applying Epoxy Paint With Anticorrosive Coating Etc Complete 95 Making Fabrication Work Using 16 Gauge Metal Sheet With Bending, Cutting, Drilling And Welding Complete . 96 Providing , Fixing And Erecting 6Mm Polycarbonate Multiwall Ultravoilet Protected Sheet For Roofing Over Fabricated Steel Structure As Per Detail Design, Including Fixing The Polycarbonate Sheet With Alluminium Angle & Flat Anodized & Dyed As Per Approved Shade Including All Water Proofing Materials, Nuts Bolts Hardware, Labour & Square Pipe, Angles, Fabrication Complete Including All Hardware Etc. As Required . ( Only Actual Area Of Polycarborted Sheet To Be Considered For Measurements ) 97 P / F Bracket For Set Top Box 98 Providing Stainless Steel Electric Kettle 99 P / F Co-Axial Copper Cable Low Voltage Grade Rg-11 100 P / F And Modifying Rfid / Coin System For Vending Machine Complete. 101 Providing Rfid Card / Coin For Vending Machine Complete. 102 Providing Hot Water / Tea / Coffee Storage Can Of 6 Litre Capacity. 103 P / F Water Cooler With Uv Water Purification System Complete Of 120 Lit Capacity Pss Storage Suitable Operating Input Voltage 240 V 50 Hz Power Supply Complete. 104 P / F Water Dispenser In Hot & Cold With Uv Water Purifier Suitable Operating Input Voltage 230V / 50Hz Power Supply Complete. 105 P / F Water Cooler With Ro + Uv Water Purification System Complete Of 120 Lit Capacity Pss Storage Suitable Operating Input Voltage 240 V 50 Hz Power Supply Complete. 106 P / F Water Dispenser In Hot & Cold With Ro + Uv Water Purifier Suitable Operating Input Voltage 230V / 50Hz Power Supply Complete. 107 P / F Insect Killer Suitable Operating Input Voltage 230V / 50Hz Power Supply Complete. 108 P / F Single Door Horizontal Chest Deep Freezer Of 200 Litres Capacity, Direct Cool Technology Suitable For Operation On 230 / 250 V, 50 Cycles Complete With Automatic Temperature Control Sealed Unit In Refrigeration System Complete. 109 Carrying Out Core Cutting Of Size 3 To 5 Dia X 1 Length In The C.C. / Rock / Stone Wall With The Help Of Pecialized Core Cutting Machine In Proper Manner And Finishing The Site As Original. 110 P / F H.D.P Container Syntex Or Alike One Piece Moulded Water Tank Made Out Of High Density Polythyler And Built Corrugated Complete. 111 P / F Iam 15V Oil Free Medium Pressure Air Compressor Reciprocating Vertical Type Water Cooled Non Lubricated With Suction Air Filter With Silencer Watercooled After Cooler With Moisture Separator V-Belt Drive Arrangement Complete. 112 P / F Cooling Tower 10 Tr 113 Making Foundation, Water And Air Pipe Line With Complete Power And Control Cabling Loading, Unloading Trasportation, 114 P / F Automatic Control Panel For Emergency Alarm System Complete. 115 P / F Copper Pipe Suitable For Refrigeration System Having Size 12 Mm Complete. 116 P / F Copper Pipe Suitable For Refrigeration System Having Size 16 Mm Complete. 117 P / F Elastomeric Nitrile Rubber / Foam Tube Type Sleeves For Over Coating And Insulating On Provided Copper Pipes Having Sizes 12 Mm 118 P / F Elastomeric Nitrile Rubber / Foam Tube Type Sleeves For Over Coating And Insulating On Provided Copper Pipes Having Sizes 16 Mm 119 P / F Rigid Pvc Pipe 20 Mm Dia.With Pvc Accessories For Drain 120 P / F Mains With Isi Mark Wp 2 X 6 Sq. Mm. 1100 V. Grade Aluminium Pvc Insulated And Pvc Sheathed Wires On G.I. Bearer Wire No. 8 Swg Complete 121 P / F Fully Automatic Line Voltage Stabilizer For Operation On Input Voltage 160 To 270V And Output Voltage 200 To 250V Rated For, Kva Maximum Load And With Voltmeter, Selector Switch, 6A / 16A Flush Type 3 Pin Socket For Output 122 P / F Fully Automatic Line Voltage Stabilizer For Operation On Input Voltage 160 To 270V And Output Voltage 200 To 250V Rated For, Kva Maximum Load And With Voltmeter, Selector Switch, 6A / 16A Flush Type 3 Pin Socket For Output 123 P / F Fully Automatic Line Voltage Stabilizer For Operation On Input Voltage 160 To 270V And Output Voltage 200 To 250V Rated For, 5 Kva Maximum Load And With Voltmeter, Selector Switch, 6A / 16A Flush Type 3 Pin Socket For Output 124 P / F Fully Automatic Line Voltage Stabilizer For Operation On Input Voltage 160 To 270V And Output Voltage 200 To 250V Rated For, 7.5 Kva Maximum Load And With Voltmeter, Selector Switch, 6A / 16A Flush Type 3 Pin Socket For Output 125 P / F Fully Automatic Line Voltage Stabilizer For Operation On Input Voltage 160 To 270V And Output Voltage 200 To 250V Rated For, 10 Kva Maximum Load And With Voltmeter, Selector Switch, 6A / 16A Flush Type 3 Pin Socket For Output 126 P / F Testing & Commissioning Approved Type Digital Key Telephone / Ip Telephone Instrument 127 P / F Testing & Commissioning Internet Protocol Digital Type Epabx For 10 Ip Extensions Complete. 128 P / F 8 Extension Card For Epabx System 129 P / F 16 Extension Card For Epabx System 130 P / F Testing & Commissioning Push Button Telephone Instrument Desk Top / Wall Mount With Caller Id Unit, Etc Complete . 131 P / F Commissioning Main Distribution Frame ( Mdf ) Box 50X50 Pairs 132 P / Laying Telephone Copper Cable 4 Pair With 0.5 Mm Dia. Laid In Provided Pvc Casing Capping / Conduit . 133 P / Laying Unarmoured Telephone Copper Cable 10 Pair With 0.5 Mm Dia. Laid In Provided Pvc Casing Capping / Conduit 134 P / Laying Lszh Armoured Multimode Optical Fibre Cable With 6 Fibres, With Core Dia 50 / 125 Lm Suitable For 1 Gbps Ethernet Distance At 850 Nm Of Wavelength, On Wall / Ceiling Or Laid In Provided Pipe / Trench 135 P / Laying Fr Grade, Pvc Armoured Multimode Armoured Multimode Optical Fibre Cable With 6 Fibres, With Core Dia 50 / 125 Lm Suitable For 1 Gbps Ethernet Distance At 850 Nm Of Wavelength, On Wall / Ceiling Or Laid In Provided Pipe / Trench 136 P / F Configuring 1-Port Mini-Gbic Sx Mutlimode Fibre Transceiver 137 Supplying, Erecting, Testing And Commissioning Amplifier 700 W For Public Address System Suitable To Operate On 230 Volts A.C. / 12 Volts D.C. Supply Complete. 138 P / F Testing And Commissioning Sound Column 30 Watts Complete. 139 P / F Testing And Commissioning Microphone Complete 140 P / F Testing And Commissioning Stand For Microphone Complete. 141 P / F Testing And Commissioning Of 2 Core Shielded Microphone Cable Complete 142 P / F Testing And Commissioning Of 1.5 Sq Mm Speaker Wire Complete. 143 P / F Digital Ammeter For Measuring Current 144 P / F Digital Voltmeter For Measuring Voltage 145 P / F Multifunction Meter 146 P / F Selector Switches For Voltmeter & Ammeter . 147 P / F Light Emitting Diode Type Indicator 148 P / F Moulded Case Circuit Breaker . A Up To 100A. B 200A. C 250 D 315 / 400A. E 600 / 630A. F 800A. 149 P / F Sp Moulded Case Circuit Breaker. A Up To 100A. B 200A. 150 P / F Busbar Chamber With Triple Pole Neutral Aluminium Bus Bar A 100A. B 200A. C 300A. D 400A. E 630A. F 800A. 151 Providing And Laying Aluminium Conductor 3.5 Core Xlpe / Pvc Armoured 1.1Kv Grade Cable A 25Sq.Mm B 35Sq.Mm C 50Sq.Mm D 70Sq.Mm E 95Sq.Mm F 120Sq.Mm G 150Sq.Mm H 185Sq.Mm I 240Sq.Mm J 300Sq.Mm K 400Sq.Mm 152 Providing And Laying Aluminium Conductor 4 Core Xlpe / Pvc Armoured 1.1Kv Grade Cable A 4Sq.Mm B 6Sq.Mm C 10Sq.Mm D 16Sq.Mm 153 Providing And Laying Aluminium Conductor 2 Core Xlpe / Pvc Armoured 1.1Kv Grade Cable A 4Sq.Mm B 6Sq.Mm C 10Sq.Mm 154 Providing And Laying Copper Conductor Core 2.5Sq.Mm Xlpe / Pvc 1.1Kv Grade Flexible Cable 155 Providing And Laying Copper Conductor Core 4Sq.Mm Xlpe / Pvc 1.1Kv Grade Flexible Cable 156 Providing And Laying Double Wall Corrugated Pipes ( Dwc ) Of Hdpe For Enclosing Cable Below Ground / Road Surface, To Required Depth Complete A 50 Mm B 75 Mm C 90 Mm D 120 Mm E 146 Mm F 160 Mm G 175 Mm H 200 Mm 157 P / F Heat Shrinkable Straight Through Joint Kit For 3 Core Etc Complete . A 70-120Sq.Mm B 150-185Sq.Mm C 240-400Sq.Mm 158 P / F Gi Strip Of Suitable Size 159 P / F M.S. Stand For Fire Bucket 160 P / F Wall Hook For Fire Bucket . 161 P / F G.I Fire Bucket 9Lit 162 P / F Instruction Chart 163 Pair Of Rubber Hand Gloves 164 Providing Standard First Aid Box With Necessary Antiseptic Cream, Medicine For Use On Wounds Due Burn, Crepe Bandage, Gauge Bandage, Medicated Ready To Use Bandage ( Band-Aid ) Adhesive Tape For Medicinal Use, Scissors, Anti-Septic Solution, Etc 165 P / F Fire Extenguisher Complete Erected With Necessary Clamp 166 P / F High Voltage Insulating Electromat Confirming To Is 15652 :2006 A Suitable For 3.3Kv. B Suitable For 11Kv. C Suitable For 33Kv. 167 Danger & Other Sign Board 168 Electrical Inspection, Compliance, Test Reports Of Earthing, Insulation Test Etc Complete. 169 P / F Analog Ammeter For Measuring Current 170 P / F Analog Voltmeter For Measuring Voltage 171 P / F Change Over Switches. A 63A. B 125A. C 200A. D 250A. E 315A. F 400A. G 630A. H 800A. I 1000A. 172 P / F C I Pipe Type Earthing Etc Complete. 173 Lt Panel, Changeover Panel, Distrubution Panel, Feeder Panel A Power Wiring Up To 63A Feeder Using Copper Wire, Lugs, Tie Saddle, Spiral Etc Complete. B Control Wiring For Metering Using Copper Wire, Ferrule, Lugs, Tie Saddle, Spiral Etc Complete. C Panel Accessories Such As Hardware, Gasket, Insulator, Backlite, Panel Knob, Panel Lock, Push Button With Indicators, Heavy Duty Connectors Earthing Arrangement, Etc Complete For Following Feeders I Up To 100A Ii 100A To 250A Iii 250A To 400A Iv 400A To 800A D Dismantling, Disconnecting Connections Of All Cables, Shifting Old Panel In Godown Etc Complete Of Following Capacity. I Up To 100A Ii 100A To 250A Iii 250A To 400A Iv 400A To 800A E Installation Of Panel At Desired Place Including Loading Unloading And Transportation Of Following Capacity I Up To 100A Ii 100A To 250A Iii 250A To 400A Iv 400A To 800A F Making New Terminations Of Main Incoming / Outgoing Cables, Etc Complete For Following Feeders. I Up To 100A Ii 100A To 250A Iii 250A To 400A Iv 400A To 800A G Interlocking, Forward / Reverse, Timing And Control Circuit / Star Delta Circuit Etc Control Wiring Using Copper Wire, Ferrule, Lugs, Tie Saddle, Spiral, Etc Complete For One Feeder. 174 Supplying Pedestal Fan 230 Volts 50 Cycles Oscillating Type Complete With Guard Complete A 400 Mm B 450 Mm C 600 Mm 175 Dismantalling Temporary Hangging Wires Accessories, Etc Complete. 176 P / F 3 Phase Heavy Duty Industrial Socket. 177 P / F 1 Phase Heavy Duty Industrial Socket. 178 Tracing Out Faults And Attending Various Breakdown A Tracing Out Fault And Attending Minor Breakdown In Wiring / Electrification Etc Complete B Tracing Out Fault And Attending Major Breakdown In Wiring / Electrification Etc Complete C Tracing Out Fault In Lt Cable / Cable Kit / Panel Removing The Connection Of Cable, Taking Insulation Test. After Fixing New Cable / Cable Kit, Making Termination Of The Cable Again Taking Insulation Test And Giving Satisfactory Test And Trials, Etc Complete. D Tracing Out Fault In Ht Cable / Cable Kit / Cubical, Removing The Connection Of Cable, Taking Insulation Test. After Fixing New Cable / Cable Kit, Making Termination Of The Cable Again Taking Insulation Test And Giving Satisfactory Test And Trials, Etc Complete. E Attendance, Checking And Assistance For Total Electrical System During General Body Meeting. 179 Providing And Spreading Stone Metal 25Mm Size For 100Mm Depth Above The Ground Level. 180 Hiring Charges For Supplying And Maintaining 230V, 50 Cycles Ac Generating Set With Its Accessories And Without Fuel, With Operator For All Shifts Complete With Continuous Running On Load / No Load As Per Requirements Complete With Self Certification A 25 To 30 Kva Capacity B 40 To 62.5 Kva Capacity C 125 Kva Capacity D 200 To 250 Kva Capacity E 400 Kva Capacity 181 Hiring Charges For Supplying And Maintaining 230V, 50 Cycles Ac Generating Set With Its Accessories And Without Fuel, Without Manpower Complete With Continuous Running On Load / No Load As Per Requirements Complete With Self Certification A 25 To 30 Kva Capacity B 40 To 62.5 Kva Capacity C 125 Kva Capacity D 200 To 250 Kva Capacity E 400 Kva Capacity 182 P / F L.T. Current Transformer Of Suitable Ratio 183 Supplying And Erecting Mini Feeder Pillar Triple Pole With 200A Mccb As Incomer And 2 Outgoing Circuits With Hrc Fuse Base And Cartridge Of 100A Consists Of Aluminium Bus Bar 500 V 200 A Complete Erected In 14 Gauge Crca Sheet Box With Supporting Angles, Self-Locks, Gasket And Slanting Top To Be Erected On Provided Foundation 184 Supplying And Erecting Mini Feeder Pillar Triple Pole With 300A Mccb As Incomer And 3 Outgoing Circuits With Hrc Fuse Base And Cartridge Of 100A Consists Of Aluminium Bus Bar 500V 300A Complete Erected In 14 Gauge Crca Sheet Box With Supporting Angles, Self-Locks, Gasket And Slanting Top To Be Erected On Provided Foundation 185 P / F Flood Light Led Fitting A 30-40W B 50W C 70 To 80W D 90 To 100W E 120W F 150W G 200W 186 P / F Street Light Led Fitting A 70 To 75W B 75 To 90 W C 100 W 187 Supplying And Erecting Street Light Wall Bracket Made From 40Mm. Dia ‘B’ Class G.I. Pipe Complete . 188 Supplying, Erecting, Testing And Commissioning Self Contained Water Cooler 230 / 250V 50 Cycles Nominal Cooling Capacity Of 40 Litres / Hr And Storage Capacity 80 Litres With Partially Stainless Steel Body Complete.. 189 Providing Multimeter Of Range 0-10-30- 100-1000 Amps And 0-300-600 Volts, Continuity Tester, Ac, Dc Voltage Tester. . 190 Providing Insulator Tester ( Megger ) Cranking Type Having Metal Body Of Range 100 Volts 1000 Ohms . 191 Providing Tong Tester ( Clip On Meter ) Of Range 0-10-30-100-1000 Amps And 0-300- 600 Volts . 192 Providing Non Contact Voltage Detector Of Range 0-600 Volts . 193 Screw Driver With Green Neon Bulb Line Tester 3.6 X 60 Mm . 194 Providing And Fixing Triple Pole And Neutral Surface / Flush Mounted Distribution Board ( Tpndb ) A Distribution Board 12 Way ( 5-4-4 ) B Distribution Board 24 Way ( 5-4-5 ) C Distribution Board 36 Way ( 5-4-6 ) D Distribution Board With Door 12 Way ( 5-4- 10 ) E Distribution Board With Door 24 Way ( 5-4- 11 ) F Distribution Board With Door 36 Way ( 5-4- 12 ) G Distribution Board ( Spndb ) One Way ( 5-4- 13 ) H Distribution Board 4 Way ( 5-4-14 ) I Distribution Board 8 Way ( 5-4-15 ) J Distribution Board With Door 4 Way ( 5-4- 17 ) K Distribution Board With Door 8 Way ( 5-4- 18 ) 195 Reconditioning, Shifting And Installation Of Transformer. A Inspection Of Distribution Transformer On Hv And Lv Side B Dismantling The Distribution Transformer Of From The Plinth / Foundation C Providing And Filling Transformer Oil D Painting Of Transformer Using Smoke Gray Paint Complete . E Providing And Rewinding Of Copper Material For Ht Coils F Heating Of Core And Winding, Including Removing Of Moisture Etc Complete G Providing Oil Arresting Sheet For Low Tension Side Of R Y B Studs, 5Mm Thick Properly Fitted In The Studs Of Transformer. H Providing Oil Arresting Sheet For Top Cover Of Oil Chamber, Lt Connection Box, Oil Tank Etc Parts , 5Mm Thick Properly Fitted In The Top Cover And Nut Bolts Of Transformer I Providing R Y B Stud Bushings Over The Oil Arresting Sheet On The Studs Of Transformer . J Reinsulation By High Quality Uniform Covering Throughout Of 11Kv Windings Using Accessories Complete K Reinsulation By High Quality Uniform Covering Throughout Of 415V Windings Using Accessories Complete L Repairing And Servicing Of Tap Changer Of Transformer M Transformer Oil Filtration N Changing Silica Jel Of Breather And Adding Breather Oil. O Loading, Unloading And Transportation Of Transformer. P Attendance, Engineering Charges For Connection Of Ht / Lt Cables And Giving Satisfactory Test & Trials Of Transformer Complete 196 Providing, Constructing 1.5 Mtr X 1.5 Mtr X 1.5 Mtr + 1 Mtr Underground Transformer Plinth As Per Rate Analysis. 197 Providing, Constructing 1.2 Mtr X 1.2 Mtr X 1.5 Mtr + 1 Mtr Underground Transformer Plinth As Per Rate Analysis. 198 Providing And Fixing Rolled Steel Joist ( Girder ) Pole 116X 100 Mm. ( 23 Kg / Meter ) 11Rmt With Provided Base Plate In Provided Foundation As Per Specifications . 199 Making Isolation Circuit Using Ab Switch D.O. Set For Single Pole & Converting The Cutpoint By Dismantling With Nessasary Material, Jumping, Earthing Along With Arrangement Of Shutdown Etc. Complete. 200 Providing C.C. Foundation Including Excavation For The Poles 60 X 60 X 1.5 Mtr Deep In 1:3:6 C.C. ( 45 X 45 X 45 ) Cm Height Plinth Duly Plastered And With Necessary Curing And Finishing In An Appr. Manner . 201 Providing And Fixing G.I. Stay Set For Poles, Including Loop Insulators At Inaccessible Height Complete 202 Providing And Fixing Ht Stay Wire 203 Providing And Fixing Approved Make, 11 Kv Lightening Arrestor With Necessory Accessories Etc Complete 204 Providing And Fixing Tension Porcelain Disc Type Insulator Suitable For 11 Kv Line Complete Erected With Suitable Hardware On Provided Cross Arms As Per Is. 205 Providing And Fixing Procelain Pin Type Insulator Suitable For 11 Kv Line, Complete Erected With Suitable Hardware On Provided Cross Arms. 206 Providing And Fixing A.C.S.R. Conductor Of Size - 6 / 1-4.09 Mm ( Raccon ) Complete Erected For Overhead Line With Striging Binding With Proper Size Of Alluminium Conductor For Binding And Suitable Size Of P.G. Clamps For Jumpering Etc. Complete 318 Kg / Km 207 Providing And Fixing A.C.S.R. Conductor Of Size - 6 / 1-4.72 Mm ( Dog ) Complete Erected For Overhead Line With Striging Binding With Proper Size Of Alluminium Conductor For Binding And Suitable Size Of P.G. Clamps For Jumpering Etc. Complete 394 Kg / Km 208 Providing And Fixing Air Break Switch Without Earth Switch 11Kv Outdoor Type Gang Operated Air Break, Triple Pole, 400A Switch Complete 209 Providing And Fixing Approved Make, 11 Kv Out Door Type Drop Out Fuse With Insulator Complete With Fuse Holders, Fuse Barrel With Metal Fitting, Fuse Element Mounted On M.S. Chanel With Working Curent Of 50 Amps Capacity Complete Erected On Provided Cross Arm. 210 Providing And Fixing Extra Thick Alkathene Pipe 10Mm Dia Erected To Enclose Bare Conductor Wires 211 Providing And Fixing Sundries Such As Earthing Powder, Danger Board Etc Accessories. 212 Providing M15 Grade Pcc Works For Plinth As Per Rate Analysis. 213 Designing, Providing, Fabricating, Installing Testing, Commissioning And Giving Satisfactory Tests Of Cubical Industrial Outdoor Type 2000A Lt Acb Changeover Panel As Per Detail Specifications, Making New Terminations Of Main Incoming And Outgoing Cables By Using Lugs Glands Etc Complete. 214 Repairing, Servicing Of 100Kva Dg Set A Providing And Filling Engine Oil 15W40 B Providing And Fixing Lub Oil Filter C Providing And Fixing Fuel Filter D Providing And Fixing Air Cleaner Inner E Providing And Fixing Air Cleaner Outer F Providing And Fixing V-Belt Set G Providing And Filling Radiator Coolant H Providing And Filling Radiator Cleaner 1Ltr Can I Dismantling Of Cylinder Heads, Turbo Charger, Refitting New Gasket, Checking All Allignments And Operation, Reffiting Assembly Again, Giving Test And Trial Complete. J Providing And Fixing Hose Pipe Set K Providing And Fixing Hose Clip Set L Providing And Fixing Fuel Pipe Set M Providing And Fixing O-Ring Set N Diesel Tank Cleaning O Servicing And Callibration Of Fip P Callibration Of Injector And Pressure Testing Q Servicing Of Charging Alternator R Servicing Of Starter Motor S Servicing Cleaning And Warnishing Of Main Alternator T Servicing, Overhaulling, Testing Of Avr, Epu Card, Relay Card, Etc Control Systems U Servicing And Overhaulling Of Turbo ( Dcarbonisation ) V Tappet Setting W Cleaning, Servicing Of Radiator And Refilling Coolant. 215 Repairing, Servicing Of Synchronization Panel By Updating Logic Software, Servicing Of Electronic Controller, Control Relays Terminations, Power And Control Wiring. Also Tightening Of Connections And Cleaning Of Panel Complete. 216 Servicing And Overhauling Of Ht Substation. A Servicing And Overhauling Of 4 Pole Ht Substation By Servicing Air Break Switch By Polishing Contacts, Applying Jelly To Contacts, Alignment Of Ab Switch, Servicing And Overhauling Of D.O. Set By Polishing Hansa And Punja, Applying Jelly To All Hansa And Punja, Changing Fuse Link Tightening Of Connections, Changing Hardware, Changing Acsr Jumper Links By Properly Lugging And Binding Using Alkathene Pipe. Ht Taping Of Connections, Checking Of Insulators, Insulation Test Of Total Installation And Earth Test Of Earthing Pits. B Servicing And Overhauling Of 2 Pole Ht Substation By Servicing Air Break Switch By Polishing Contacts, Applying Jelly To Contacts, Alignment Of Ab Switch, Servicing And Overhauling Of D.O. Set By Polishing Hansa And Punja, Applying Jelly To All Hansa And Punja, Changing Fuse Link Tightening Of Connections, Changing Hardware, Changing Acsr Jumper Links By Properly Lugging And Binding Using Alkathene Pipe. Ht Taping Of Connections, Checking Of Insulators, Insulation Test Of Total Installation And Earth Test Of Earthing Pits. 217 Servicing And Overhauling Of Transformer. Servicing And Overhauling Of Transformer By Changing R Y B Stud Bushing Of Ht, Lt Side, Oil Sheet For Low Tension Side Of Y B Studs, Top Cover Of Oil Chamber. Servicing Of Tap Changer, Taping Connections, Testing Of Oil Samples And Taking Insulation Test Of Transformer. Carrying Out Short Circuit, Open Circuit Test And Resistance Test Of Transformer. Changing Silica Jel Of Breather. Transportation, Attendance, Making Connection Of Ht And Lt Side As Well Giving Satisfactory Test And Trials Transformer. 218 Servicing Of Oltc By Checking Operating Mechanism, Alignment, Applying Jelly Various Parts, Checking Of Control Panel Operations And Replacement Of Provided Indicators, Switches, Control Fuses, Hardware, Insulator, Gasket, Polishing Contacts, Power And Control Wiring Using Appropriate Wire, Lugs, Tie, Saddle, Ferrules, Termination Of Incoming Outgoing Cables Required. Cleaning Of Panel, Tightening All Connections Etc Complete. 219 Servicing And Overhauling Of Amf Panel. Servicing Of Contactor, Terminations, Power And Control Wiring Using Appropriate Wire, Lugs, Tie, Saddle, Ferrules, Bus Bars, Changing Hardware Insulator, Gasket, Indicators, Push Buttons And Material Procured From Material List Like Voltmeter, Ammeter, Selector Switches, Termination Incoming Outgoing Cables As Required. Also Tightening Of Connections And Cleaning Of Panel Complete. A Up To 200A B 200A To 400A 220 Servicing And Overhauling Of Distribution Panels. Servicing , Repairing Of Distribution Panels By Checking Terminations, Power And Control Wiring Using Appropriate Wire, Lugs, Tie, Saddle, Ferrules, Bus Bars, Changing Hardware Insulator, Gasket, Provided Indicators, Voltmeter, Ammeter, Selector Switches Termination Of Incoming Outgoing Cables As Required. Cleaning Of Panel, Tightening Of All Connections Of Feeders Following Capacity. A Up To 32A B 32A To 63A C 63A To 100A D 100A To 150A E 150A To 200A F 200A To 250A G 250A To 400A H 400A To 630A I 630A To 800A J 800A To 1000A K 1000A To 1250A L 1250A To 1600A
Contract Date: May 25, 2026 Contract Value : 23.96 Lakh
Government Departments No of Bidders 3
Maharashtra View Result →
2.
Educational and Research Institute #10861389 AOC
Tender For Dg Power Supply To Guest House; 1 M.V. PVCA/XLPA CABLES: Supply, installation testing & commissioning of 1.1KV grade PVC/XLP insulated, inner sheath tapped, outer sheath PVC extruded, GI strip/armored, multi stranded/ Aluminum conductor power cable as per IS 1554 specifications, FRLS grade anti- rodent and anti-termite PVC (ST-2) outer sheathed cable, in ground at a depth of 900mm below ground level, sand bedding, laying of baked bricks on side and top, temporary reinstatement, back filling, dewatering, consolidation, disposal of excess earth within the radius of 500m and making good to the original finish etc. orfixed on wall/column/slab/in existing GI Cable trays/hume pipes/ trenches by 5mm thick GI spacer fixed/coach screws/anchor fasteners in brick/stone wall /column/slab with 2mm thick GI saddle, all fixing accessories etc. complete including painting of saddle /flat/angle iron etc. The space between two supports shall be generally 600mm Etc. all as per the instructions of Engineer-in-charge-IOP.The tinned copper earth wires to be laid along with the cables should be painted with two coats of black bituminous compound for earth wire in ground & Jointing of the earth wire shall be solder joints with tinned copper cable sockets & GI nuts & bolts.Note: Scope includes all types of masonry work required making good to its original finish of holes through wall, slopes etc. after laying of the cable. Make of cables: Finolex/Polycab/CCI or approved equivalent of the same. 2 01 no x 3 ½ core x 185 Sqmm Al. PVCA/XLPE cable and 01 nos. of 8 SWG tinned copper earth wire. (From Auditorium main panel to Proposed Change overpanelto be installed in feeder pillar panel room) 3 DISTRIBUTION BOARDS: Supply, Installation, testing & commissioning of following medium voltage (415V) TP&N/ SP & N distribution boards single door complete with necessary SFU, MCCB, MCBs, etc. suitable for wall mounting with M.S. frame work of 40x40x5mm angle mounting with M.S. enclosure fabricated out of 16SWG thick M.S. CRCA sheet with concealed hinged door, cam type locking arrangement, dust and vermin proof with IP-42 protection, Front operated front access, all live parts shall be shrouded, all bus bars shall be insulated with heat shrinkable sleeves, SMC/DMC shrouds and Bus bar supports shall be used etc. Suitable tinned copper bus bars have to be provided for all phases, neutral and earth connections both for incoming and outgoing connections.Cable end box, wire way box, including interconnections with appropriate size of PVC insulated copper conductor, phase barriers, earth of DB, enameled danger board, name plate, neoprene gasket for joints & door has to be provided. Necessary metal treatment, two coats of red oxide paint & Powder coated with color shade of RAL 7032. A suitable Bakelite sheet with necessary cutouts for knobs/ operating levers of MCB’s/ MCCB/ SFU etc is to be provided duly fixed on to the cabinet with nuts and bolts/ screws. The front door (MS sheet) should have the name of the DB in anodized aluminum plate. Phase distribution drawing etc. all as per drawings specifications etc. relevant IS & instruction of Engineer-in-charge (G.A. & fabrication drawing to be got approved before fabrication)Note: 1.MCB’s shall be minimum 10KA breaking capacity2. All tinned copper bus bars should be minimum of 200A rating or more than that as mentioned in the drawing.3. All SFU units should have to be provided with HRC fuses4. Make of SFU: L & T, Siemens, or approved equivalent of the same & make of MCB: Legrand or approved equivalent of the same.5. All feeders including the Incoming are to be provided with proper nomenclature in anodized Aluminium plates near the MCB, output terminals & on DB as per requirement/ as per instruction of EIC.6. All terminals inside the DB has to be provided with suitable copper lugs/sockets for connection.7. For the feeders above 125A rating output connection is to be made directly from the Bus bars and the output bus bars has to be extended suitably to the cable bay box for connection of the output cables.8. Suitable Tinned Copper Bus-bar has to be provided for the running earth in each DB.9. The DBs are to be fabricated in electrical panel fabrication shop approved by Institute of Physics. The DBs will be inspected by IOP EIC in 3 stages and for which it has to be informed accordingly. 4 Main Change over panel (Located in NISER panel room) The panel will be wall mounting type and will contain the following items:1. 630A, 04 pole Changeover Switch – 01 no.2. 400A TPN SFU with Fuse – 01 nos. (For incomer)3. 250A TPN SFU with Fuse – 01 no. (Outgoing)4. 125A TPN SFU with Fuse – 02 nos. (Outgoing)Note:1. The connection and placement of the above items is to be done as per the circuit diagram will be given by IOP. 2. All connections inside the panel is to be made by suitable copper bus bars of proper ratings.3. There should be sufficient length of Copper Bus Bar and end termination space for connection of the followingcables: Incomer- 1- 2x185Sqmm XLPE, Armored, 3 ½ Core cables (From Auditorium main Panel) Incomer -2 – existing 1x 185Sqmm XLPE, Armored, 3 ½ Core cables. (From Feeder Pillar Panel), to be disconnected from the Feeder Pillar panel and to be connected to the changeover panel within the scope of this job.Outgoing – 1 - 1x 185 Sqmm XLPE, Armored, 3 ½ Core cables (To Guest House) to be disconnected from the Feeder Pillar panel and to be connected to the changeover panel within the scope of this job.Outgoing – 2 – existing 2x35Sqmm XLPE, Armored, 3 ½ Core cables, (Street Light), to be disconnected from the Feeder Pillar panel and to be connected to the changeover panel within the scope of this job.Gland plates with required gland holes are to be provided on both sides of the box. The make ofChange over switch, TPN SFU should be of L&T/ Siemens or approved equivalent of the same 5 The panel will be wall mounting type and will contain the following items:1. 400A TPN SFU with Fuse – 01 nos. There should be sufficient length of Copper Bus Bar and end termination space for connection of the followingcables: Feeder-1- 04x185Sqmm cableFeeder-2-03x185Sqmm cableFeeder-3-02x185Sqmm cableGland plates with required gland holes are to be provided on both sides of the box. The make of TPN SFU should be of L&T/ Siemens or approved equivalent of the same 6 END TERMINATION OF ARMOURED & FLEXIBLE CABLES:End termination and connection of the following cables by crimping with supply of all jointing materials like tinned copper cable sockets, cable glands, gland earthing insulation tape, flux, duplicate interconnection between gland earthing strip and the nearest earthing bus terminals as per the drawing, specifications, Aluminum cable tag is to be provided with each end termination and all as per the instruction of the Engineer in charge. Make of lugs/sockets: Dowels/Jainson. 7 3 ½ core x 185 Sqmm Al. PVCA /XLPE cable 8 Rearrangement of the existing 09x185Sqmm cables in the trench of Auditorium main Panel to facilitate the end termination of those cables and laying of the above mentioned new cables. For the same job the following points has to be carried out within the scope of this job:1. It will be required to excavate the soil (Appx. 50 Cumtr.) outside panel room to facilitate the drawing of the existing 09 cables to outside and again reinserting the same into the trench along with the new cable.2. The total labour required for the same, the tools, and any other items required for this job is within the scope of this job.3.The excavation of soil has to be carried out with utmost care and slowly to avoid any type damage to the pile of cables lying under the soil at the same place.4. The existing 09 nos. of cables are to be re-laid inside the trench to be drawn on the wall (2mtr. Height) near auditorium panel providing suitable “C” type GI flat with GI clamps and to be connected to the three 400A TPNs mentioned in item no.2.5.5. Necessary cuttings in Chequered plates of the trench for cable entry/exit is included in the scope of this job.Bidders are advised to visit the site and access the quantum of job before quoting for the same.
Contract Date: Feb 24, 2026 Contract Value : 4.19 Lakh
Boards / Undertakings / PSU No of Bidders 4
3.
Defence #10832999 Price Bid
Tender For Additional / Alternator To Swimming Pool And Other Works Under Age B/R Iii At Chandimandir; 1 Dubbing out average 20mm thick on irregular faces of walls, exposed reinforced surfaces, in Cement and Sand mortar 1:4,including necessary scaffolding & safety arrangement for plaster upto & including 4 storey building complete all as specified. 2 Brick work using old size bricks, straight or curved on plan exceeding 6.00 metre mean radius built in cement mortar 1:6, complete all as specified and directed. 3 providing cement concrete type D2, 1:4:8 using 40 mm graded stone aggregate,as in foundations, filling and mass concrete etc., complete all as specified and as directed 4 100mm thick PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) as in sub base etc, finished even and rough complete all as specified and directed. 5 25mm thick PCC 1:2:4 type B-0 (using 12.5mm graded crushed stone aggregate) as in sub base finished fair and rough without using extra cement, complete all as specified and directed. 6 Coloured non skid porcelain tiles exterior grade 300x300x 8-10mm thick heavy duty (Endura from Johnson or equivalent) as in floor, set and jointed in neat slurry and pointed in coloured cement to match the colour of tiles over and including screed bed or bedding layer of 15mm thick in cement mortar 1:6, complete all as specified and directed 7 Glazed coloured ceramic tiles in vertical surface 300mm x 450mm x 7mm thick, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile, over and including 10mm thick rendering in cement mortar 1:4, complete all as specified and directed. 8 Granite (of any type) tiles 20mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing, including 15mm thick in cement mortar 1:6, complete all as specified and directed 9 Coloured vitrified ceramic tiles, 10mm thick (square/rectangular ) , area of each tiles exc 0.18 Sqm but n.exc 0.36 sqm, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile, over15mm thick screed bed in cement mortar 1:6, complete all as specified and directed. 10 20mm thick Granite work (of any type table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like in, set in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite compelte all as specified and directed. 11 Kota Stone Slab flooring, 18-20mm thick, best quality over and including cement screed bed 15mm thick in cement mortar 1:6, laid and jointed with grey cement slurry and pointed with grey cement mixed with pigment to match the shade of the slab including cutting, rubbing, grinding and polishing (Mirror finish) complete all as specified and directed. 12 Factory made machine pressed, pre polished, coloured chequered cement concrete tiles 250mm x 250mm x 20-22mm thick (with grey cement and no pigments), set, jointed and pointed in neat cement slurry with grey cement with pigment to match the colour of tiles, laid over and including 15mm thick screed bed in cement mortar 1:6, complete all as specified and directed. 13 Plain cement mortar 1:3:6 (type C-2 using 20mm graded aggregate), 75mm thick as in Plinth protection , finishing cement concrete even and smooth without using extra cement,all as specified.Note: 10mm construction joint will be provided and panel should not be more than 3metre in length and joint filled with filler bitumen and sand in ratio (1:3) 14 Two coats of oil bound distemper on wall surfaces over a coat of primer including preparation of new plastered surfaces complete all as specified and directed 15 Preparation of new plastered surfaces of walls and applying two coats of cement base paint, complete all as specified and directed. 16 Applying Two or more coats on new plastered surfaces of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paintof required shade (Company Depot Tinted) with silicon additives @ 1.43 liter/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm complete all as specified and directed. 17 Prepartion of new surface and applying two coat of premium acrylic emulsion weather proof exterior paint over a coat of primer complete all as specified and directed. 18 Rendering 15mm thick in Cement and Sand mortar 1:4 overfair faces of brick / concrete ,finished even and smooth without using extra cement, inclunding using water proofing compound complete all as specified.Note : WPC shall be measured and paid separately. 19 Taking down cement plaster from brick walls or concrete surfaces including raking out joints, hacking out for key, scrubbing down with water complete all as specified and directed and removing rubbish etc. complete all as specified and directed. 20 Rendering 15mm thickin Cement and Sand mortar 1:6 over brick or concrete surfaces finished even and fair without using extra cement complete, all as specified and directed. 21 PCC 1:3:6 type C-1 (using 20m graded crushed stone aggregate) as in roof padding, finished fair and even without using extra cement, complete all as specified and directed. 22 15mm thick (average thickness) rendering on roof surfaces inclduing flashings and junction of parapets etc finished even and fair in cement mortar 1:4 using water proofing compound as per manufacturers instruction after brushing cement slurry complete all as specified and directed 23 Supply only integral water proofing compound complete all as specified & directed. 24 3mm thick Atactic polypropylene polymer (APP) modified prefabricated water proofing membrane, based polymeric membrane minimum weighing 3kg/sqm andreinforced with polyester non woven fabric (weight not less than 150 gm/sqm) laid over a coat of bitumen primer @0.40L/Sqm by same membrane manufacturer of density 0.87 to 0.89 kg/L at 25° C temperature and viscosity 70 to 160 CPS. The membrane shall be laid using butane torch and sealing all joints etc after preparing the surface as per standard practice and as per manufacturer instructions and finished, complete all as specified & directed. 25 Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc. complete allas specified and directed. 26 Factory made steel window box type with side hung shutters including box type hinges and oneshop coat of red oxide primer, 125mm steel handle-02 Nos mild steel ISI marked tower bolt 125mm size (minimum 2 for each shutter) complete with glazing bars, dovetailed or welded fixed with and including MS flat of suitable size for fixing grills and guards bars etc , complete all as specified. 27 Sheet glass 4mm thick, ordinary quality and glazing with oil putty in square, area not exc 0.5 sq. mtr in each pane,complete all as specified and directed. 28 Pressed steel frames 125mm x 60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc,including filling of PCC 1:3:6 in hollow frame complete all as specified and directed. 29 35mm thick Plain framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressuretreated, all as specified and directed. 30 Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 45 x 70 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately). 31 Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of size 30mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer?In- Charge 32 Butt hinges 100mm size, of extruded aluminum alloy with galvanisedmild steel hinge pin, anodised, type C-21, complete all as specified and directed. 33 200 mm size aluminium anodised barrel tower bolt of extruded section complete all as specified and directed. 34 150 mm extruded aluminium handles cast typecomplete all as specified and directed. 35 Aluminum alloy, anodized, sliding door bolt 250mm long hasp , staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminum alloy and fixed complete all as specified and directed. 36 Factorymade fixed type steel ventilator with glazing bar compelte all as specified and directed. 37 Galvanised mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18 mm and fixed with stainless steel wire staples, complete all as specified and directed. 38 preparation of new wooden surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed. 39 Preparation of new steel surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint complete all as specified and directed. 40 Two coats of synthetic enameled paint on steel and iron surfaces over one coat of red oxide primer on surfaces over 10 cm width or girth including preparation of new surfaces complete all as specified & directed. 41 Two coats of synthetic enamel paint over priming coat onnew stone and concrete surfaces of any description not otherwise described over 10 cm width or girth including preparation of new surfaces complete all as specified 42 Hollow PVC Wall Lining consisting of 5mm thick Plain colour PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per specifications and drawing, complete all as specified and directed(Note : Colour/design and pattern shall be as decided by the GE) 43 Providing & fixing hangers of 6 mm dia. aluminium (upto 1200mm length), adjusting level fixed to roof slabs by means of ceiling cleats made out of G.I. flat of 40 x 3 mm size, 60mm long and expansion hold fasteners of 12.5mm dia, 40mm long with and including anodised aluminium snapgrid of size 605mm x 605mm, framed work for false ceiling with and including 4mm thick nonasbestos fibre cement building boardsfixed in aluminium framework with screws, complete all as specified and directed 44 Providing & fixing hangers of 6 mm dia. aluminium (upto 1200mm length), adjusting level fixed to roof slabs by means of ceiling cleats made out of G.I. flat of 40 x 3 mm size, 60mm long and expansion hold fasteners of 12.5mm dia, 40mm long with and including anodised aluminium snapgrid of size 605mm x 605mm, framed work for false ceiling with and including 4mm thick nonasbestos fibre cement building boardsfixed in aluminium framework with screws,fixed as in repair complete all as specified and directed 45 Rolled sections as in main and cross beams, hip and jack rafters,purlins where connectedto common rafters and running rails and guidesforsliding doors, fixedwithangle cleats or other connecting plates, conforming to Fe-290 Gde E165, all as specified and directed. 46 Mild steel framed work as in doors or gates of angles or other sections with gusset plates complete drilled for fixing of steel sheeting or other covering.Doors etc to be prepared for hanging or sliding with including hooks and hinges (excluding of covering steel sheeting) fastening, locking arrangement, etc conforming to Fe-410-O or Fe-310-O all as specified and directed. 47 Mild steel framed work as in doors or gates of angles or other sections with gusset plates complete drilled for fixing of steel sheeting or other covering.Doors etc to be prepared for hanging or sliding with including hooks and hinges (excluding of covering steel sheeting) fastening, locking arrangement, etc conforming to Fe-410-O or Fe-310-O including dismantling old iron all as specified and directed. 48 Mild Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240, complete all as specified & directed by Engineer-in-Charge 49 Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bendingspirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm complete all as specified and directed. 50 TMT bars for reinforcement, 6 to 8mm dia & over cut to length, bend to shape required, including cranking, bending spirally for hooping for columns hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified & directed by Engineer-in-Charge. 51 Pre-painted galvalume aluminium zinc (AZ-70) coating GI based corrugated steel sheeting 0.50 mm thick any colour having tensile strength 550 Mpa as in roof coverings/cladding to wall, fixed with self tapping screws etc , complete all as specified & directed by Engineer-in-charge. 52 Powder coated aluminium(minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge, including making good dismantled portion with PCC (1:2:4) type B-1 in CM 1:3 complete all as specified and directed. 53 5.00mm thick ordinary quality tinted glass,fixed to aluminum frame workin panels exc 0.5 Sqm in each pane, complete all as specified & directed. 54 Door closer hydraulically regulated aluminum (die cast) body, designation No 2, universal type, suitable for door shutters of 701mm to 850mmin width and of weight between 36 to 60 Kg,complete all as specified and directed. 55 Demolition of cement concrete (unreinforced) any description and in any position complete all as specified. 56 Demolition of stone slabs and tiles of any description or thicknessin floors laid, bedded and pointed in any mortar complete all as specified and directed. 57 Surface dressing n.exc 15cm deep in hard dense soil complete all as specified and directed 58 Hard core ofbroken stone or boulders of gauge of guage n.exc 63mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed. 59 Providing and laying 80mm thick factory made chamfered edge cement concrete paver block of M-30 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand; complete all as speciied and directed. 60 Cement concrete type B-0, 1:2:4 using (12.5 mm graded crushed stone aggregate) as in roof kerbs or mud stops, rounded or chamfered on edges in lintels upto 1.5m clear span, cills, steps, seismic and other similar bands, plinth courses, parapets and railings upto 60 cm in height, copings, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, including the use of forms or moulds with plain faces complete all as specified and directed. (Cement concrete item shall be reinforced, where ordered. Reinforcement shall be measured and paid separately). 61 Excavation in trenches in hard/dense soil not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth for foundation etc. or for shafts, wells cesspits, manholes, pier hole etc. and getting out, complete all as specified. 62 Returning filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm depth , complete all as specified and directed. 63 Removal of excavated material to distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point , complete all as specified and directed. 64 Reinforced cement concrete, 1:1½:3(nominal mix,type A-1, using 20mm graded crushed stone aggregate) as in beams, cantilevers , bressumers,lintels over 1.5m span, all as specified and directed . (reinforcement shall be measured and paid for separately). 65 Reinforced cement concrete, 1:1½:3(nominal mix,type A-1, using 20mm graded crushed stone aggregate) as in chajja and the like, complete all as specified and directed (reinforcement shall be measured and paid for separately). 66 Material and labour form work to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. for roughly finished flat surfaces of concrete, all as specified. 67 Form work to chullah hoods, chajjas and similar items including edges / sides and soffits of lintelsetc rough finished surface of concrete flat complete all as specified and directed. 68 Spreading and levelling in layers n exc. 25 cm thick and well ramming including watering as required complete, all as specified. 69 Dismantling floor hearth or wall tiling including cementmortar bedding (but not backing) removing serviveable tiles to store and rubbish off the premises complete all as specified and directed 70 Taking down shutter of any description exc 1 Sqm but n.exc 2 Sqm each complete all as specified and directed. 71 12mm thick toughned glassas in hinged doors, partitions automatic doors and similar work including cutting to shape, drilling holeswith necessary screws/ beading, rubber packing, L patch bottom and top, self closing patch etc,complete all as specified and directed.NOTE : Decoratiion/Design or unit name, emblem, crest over glass shutter will be approved by Engr-in-Charge before executionand the rates are inclusive of the same 72 Double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty complete all as specified and directed. 73 300 mm long stainless steel handle, fancy type , fixed to toughened glass, complete all as specified and directed. 74 Stainless steel lock for 10-12mm thick glass door, having knob inside with three keys, satin finish, complete all as specified and directed. 75 Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. complete all as specified and directed. 76 Material and labour forpoint wiring with approved colour code multi stranded copper conductor, PVC insulated and unsheathed FRLSH cable of size 1.5 Sqmm ,1100 volts grade, two run of single core cable for phase & neutral and one run of single coremulti stranded copper conductor, PVC insulated and unsheathed FRLSH cable of size 1.5 Sqmm ,1100 volts grade for earth continuity conductor to common earth and connected to earth dolly in and including new concealed PVC conduit terminated on and including new modular sunken box and suitable size of frame, cover for mounting switch, socket and regulator fixed on surface flush with wall , comprising ofOne light /bell/buzzer point controlled by one switch or one fan point controlled by one switch &fan regulator, complete all as specified and directed. Note : Unit rate is inclusive of making good the disturbed surfaces by provding by wall putty/POP after mason work and finshing to match the original and nothing extra shall be paid on this account.Note :Unit rate is inclusive of cutting chases in wall /foor/PCC and making good the disturbed surfaces to match the original and nothing extra shall be paid on this account. 77 All as per serial item 76 herein before but for socket outlet 3 pin 6Amps on same board complete all as specified and directed 78 All as per serial item 76 herein before but for socket outlet 3 pin 6 Amps on independentboard complete all as specified and directed 79 All as per serial item 76 herein before but One socket outlet three pin ,6/16 Amp, independent board, with 2.5 Sqmm (nominal area ) FRLSHcable & 2.5 Sqmm (nominal area) cable as earth continuity conductor 80 Switch modular type (ISI marked), single pole, one way 6 Amps, one module(ISI marked), complete all as specified & directed. 81 Switch modular type (ISI marked), single pole, one way 16 Amps, one module(ISI marked), complete all as specified & directed. 82 Socket shutters outlet 2/3 pin 6 Amp modular type multi purpose two module (ISI marked), complete all as specified & directed. 83 Socket shutters outlet 2 in 1 pin 6/16 Amp modular type multi purpose combined 2 module (ISI marked), complete all as specified & directed. 84 Modular switch type stepped fan regulator, single pole, 230 volt two module complete all as specified and directed. 85 Ceiling rose, PVC or polycarbonate of size 65mmx50mm three terminals (ISI marked) all as specifiedand directed by Engineer-in-charge. 86 Lamp holder, PVC/Polycarbonate type with back plate modular type fixed on wall suitable for batten fitting ,complete all as specified and directed. 87 LED lamp9 watts, B-22 type complete all as specified . 88 Disconnecting the power supplyand taking down carefully by unscrewing from boards fittings and fixtures such as DBs, Junction Box, Panels of any size complete with all MCCBs ,MCBs etcand removing from site, Complete all as specified and directed . 89 MCCB, 125 Amps, four pole, 3 phase , 16KA, 415 volt with adjustable thermal andmaganetic release, with proper thimble complete all as specified and directed 90 Vertical TPN distribution board double door flush mounting with provisions for MCCBs incomer upto 125 Amps & outgoing 4 way having IP 43 protection Complete all as specified and directed . 91 TPN distribution board double door flush mounting with provisions for MCB TPN 6 way, 415 volts having IP 43 protection Complete all as specified and directed . 92 MCB DB, IP 43 protection, powder coated double door with locking arrangement suitable for surface and flush mounting, 08 way SPN with 200 Amps busbar 240V completed all as specified and directed. 93 MCB, DP, 240 volt,32Amps, 10 KA , B series including connection with suitable size aluminium / copper lugs complete all as specified and directed 94 MCB, SP, 240 volt,40 to 63Amps, 10 KA , C series including connection with suitable size aluminium / copper lugs complete all as specified and directed 95 MCB SP , 240 volt, 6Amps to 32Amps, 10 KA , C series including connection with suitable size aluminium / copper lugs complete all as specified and directed 96 MCB , TPN/FP 40 to 100 Amp 415 volts, 16 KA , C series including connection with suitable size aluminium / copper lugs complete all as specified and directed 97 Single pole and neutral enclosure with a two pin and earth plug and socket complete with one SP 20 Amp MCB complete all as speicified and directed. 98 Ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) and provision of flexible copper cable 3 core from ceiling rose tofan complete all as specified and directed. 99 LED light fitting 1x9W/1X10W bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size,complete all as specified and directed. 100 LED lights fitting 1x 20W, 220V,AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose completecomplete all as specified and directed. 101 LED lights fitting 1x 20W, 220V,AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete fixed as in repair complete all as specified and directed. 102 LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size fixed as in repair complete all as specified and directed. 103 Exhaust fan energy efficient metallic blades heavy duty turbo force of size 300mm sweep, 1400 rpm, AC 230 volts complete with louvers shutters mounting on wall with holding down bolts, nuts, washerscomplete all as specified and directed. 104 Wall mounted fan PVC body, 400mm sweep, 230 volt , AC,quick start torque motor with copper winding complete all as specified and directed. 105 LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC surface type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size ncluding taking down any type ceiling fittingcomplee all as specified and directed. 106 LED flood light fitting 100 Watt 6500K outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrision resistantincluding thermal management in multiple optics complete with IP 65 protectioncomplete all as specified and directed. 107 Suface mounting back lit LED 1 x 4 tile in CRCA housing with full opel diffuser for soft & glare free distribution panel with surge protection complete including cutting hole of required size in POP/false ceiling making good disturbedincluding taking down any type ceiling fittingcomplee all as specified and directed. 108 Taking down carefully old copper or aluminium sub main wiring of any Nos of wiring and size with earth wire on wooden batten/ surface conduit/ casing- capping complete with its all accessories and making good disturbed surfaces of wall , floors etc complete all as specified and directed. 109 Sub main wiring with two singlecore FRLSH PVC insulated and unsheathed cable with copper conductor of size 6 Sqmm (nominal area), 1100 Volt grade(with approved colour coding as per IS) with and including continuous earth wire of size 6 Sqmm PVC insulated and unsheathed FRLSH multi stranded copper conductor 1100 volts grade , and connected to main board drawing throughPVC concealed conduit 25mm size(minimum size), cutting chases in walls for PVC concealed conduit and making good the disturbed surfacesby providing by wall putty/POP after mason work and finshing to match the original surfaces and nothing extra shall be paid on this account all as specified and directed.NOTE: (i)Two runs of cable, one run of earth wireshall be considered as one running metre(ii) colour code shall be Red for phase, Black for neutral and green for earth 110 Earthing complete with galvanized steel earth plate electrode 60cmx60cmx6.00mmburried directly in ground vertically to a depth not less than 2.25m below normal ground level, with top edge of the plate not less than 1.5m below normal ground level, earth plate surrounded by 15cm thick and packed alternate layers of charcoal dust and common salt, connected with and including earth lead of GI wire 4mm dia (8 SWG) by means of bolts, nuts, check nuts and washers of galvanized iron or thimbles and other end of the earth wire connected to main switch board and protected by galvanized iron pipe light grade 15mm dia bore including watering pipe of20mm dia, GI light grade (ISI marked) with funnel and wire mesh, including all necessary excavation and earth work, PCC chamber in plain cement concrete (1:3:6) type C-1 and pit cover of presast RCC with MS frame etc and all as shown in electrical plate No 3 of MES Sch Part-I (2009), complete including dismantling of old earthing, all as specified and directed. 111 Earthing complete with galvanized steel earth plate electrode 60cmx60cmx6.00mmburried directly in ground vertically to a depth not less than 2.25m below normal ground level, with top edge of the plate not less than 1.5m below normal ground level, earth plate surrounded by 15cm thick and packed alternate layers of charcoal dust and common salt, connected with and including earth lead of GI wire 4mm dia (8 SWG) by means of bolts, nuts, check nuts and washers of galvanized iron or thimbles and other end of the earth wire connected to main switch board and protected by galvanized iron pipe light grade 15mm dia bore including watering pipe of20mm dia, GI light grade (ISI marked) with funnel and wire mesh, including all necessary excavation and earth work, PCC chamber in plain cement concrete (1:3:6) type C-1 and pit cover of presast RCC with MS frame etc and all as shown in electrical plate No 3 of MES Sch Part-I (2009), completeall as specified and directed. 112 LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver,includinglamp bracket upto 1.5metre length as per suitable for fitting including clamp with impact and corrosion resistant including thermal management in multiple optics complete with IP 66 protection, including taking down old street lght complete all as specified and directed. 113 LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver,includinglamp bracket upto 1.5metre length as per suitable for fitting including clamp with impact and corrosion resistant including thermal management in multiple optics complete with IP 66 protection,complete all as specified and directed. 114 XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 25 sqmm, 3.5core, laid in trenches , sleeving through pipes of fixed on poles & wall or laid under floors inlcuding jointing with suitable size of alumunium lugs as specified and directed. 115 32mm outer dia, double walled corrugated (DWC) HDPE duct pipe conforming to IS 14930 Part-II with anti rodent and non flame propogating properties of approved colour with fittings for cable protection from approval make complete , all as specified and directed
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 2
4.
Housing Urban and Rular Development #10803700 Price Bid
E-Quotation No.5 For 2022-23 E Rate Quotation For Preparation Of Ssr For Various Item Which Is Mention In Notice , For Steel Structure / Tmt -Providing & Applyingduraclean- Wris An Organic Polymer For Conversion Of Unwanted Substrate ( Burr ) On Metal Surface Crystal Structure Modification To Remove Oxide By High Pressure Waterjet Cleaning / Grinding, Wire Brush, Washing Or Mopping Also Removing Loose Particles ( Using Other Mechanical / Manual Means ) . Measure The Burr On The Surface By Burr Measuring Gauge, If The Burr Is Above 25 Microns Repeat The Cleaning Till Burr Is Below 25 Microns. Apply Duracap Is A Unique One-Pack Cold Metalizing Process Consisting Of Blend Of Active Ceramic, Alumina And Modified Polymer. Duracap Forms A Dot Matrix Coating On The Surface, Which Gives Better Adhesion With Substrates. Apply 2 Coats With A Thickness Upto 40 Micron On Prepared Metal Surface. Duracap Ensures Good Corrosion Resistance, Its A Weldable Primer Also Work As A Uv Reflector Etc. As Per Manufacturers Specification ( Using Other Manual / Mechanical Means ) . After Primer Application Base Coat Is Done Which Is Named As Duraguard A 3 Pack System , This Is A Blend Of Water Miscible Epoxy Andgives Properties Like Ant Rodent, High Corrosion Resistance, Chemical Resistance As Well As High Abrasion & Impact Resistance Etc.As Per Manufacturers Specification ( Using Other Manual / Mechanical Means ) For Concrete Surface -Providing & Applying Impermeable, High Compressive Strength, Monolithic Application, Excellent Bond Strength, High Abrasion Resistance, Uv Resistance, Self-Curing, Non-Toxic Polymer Based Cementitious Mortar Named Aspoly Ironite Ceramic Cementitious ( Picc ) Of Dimple Chemicals & Services Pvt. Ltd. Which Consists Of Nicomix Series + 53 Grade Cement + Water For Resurfacing Of Concrete Surfaces To A Thickness Upto 10 Mm Or As Per Surface Conditions And Also Treatment Of Honey Combing Areas Etc. Cleaning Will Be Done By Remove All Loose Particles, Dust Particles Or Any Other Foreign Material / Particles Using Manual Or Mechanical Means. After That, Clean The Concrete Surface With Special Chemical Named As Steripure 10 Of Dimple Chemicals & Services Pvt. Ltd. For Removing Of Algae Fungi Followed By High Pressure Water Jet And Compressed Air Blower. Applybond Coat A Water Miscible Epoxy Named As Kelox R 101 + Kleox H 404 Of Dimple Chemicals & Services Pvt. Ltd. ( Using Manual / Mechanical Means ) Before Picc Application, It Ensure Strong Adhesion With Old Surface To New Picc Mortar. Complete As Per Specification Including Cost Of All Materials, Machinery, Labour, Scaffolding, Insurance Chargesas Directed By The Engineer In Charge. , Providing & Grouting By Polyceramic Cementitious Of Dimple Chemicals & Services Pvt. Ltd. Which Consists Of Nicgrout G 06 + 53 Grade Cement + Water As Per Requirementto Reduce The Porosityof Concrete / Masonry Structure And To Increase The Strength Of Structure Usinggrouting Pipes, Grouting M / C, Mixer Etc And All Relevant Safety With All Leads And Lifts, Material, Machinery, Labour, Scaffolding Etc. Complete As Per Specification And As Directed By Engineer-In-Charge. , Top Terrace Waterproofing -- Providing & Applying Impermeable, High Compressive Strength, Monolithic Application, Excellent Bond Strength, High Abrasion Resistance, Uv Resistance, Self-Curing, Non-Toxic Polymer Based Cementitious Waterproofing Mortar Named Aspoly Ironite Ceramic Cementitious ( Picc ) Of Dimple Chemicals & Services Pvt. Ltd. Which Consists Of Nicomix Series + 53 Grade Cement + Water For Waterproofing Of Concrete Surfaces Of Terrace To A Thickness Upto 5 Mm Or As Per Surface Conditions And Also Treatment Of Honey Combing Areas Etc. Cleaning Of Existing Terrace Surface Upto Mother Slab Will Be Done By Remove All Loose Particles, Dust Particles Or Any Other Foreign Material / Particles Using Manual Or Mechanical Means. After That, Clean The Concrete Surface With Special Chemical Named As Steripure 10 Of Dimple Chemicals & Services Pvt. Ltd. For Removing Of Algae Fungi Followed By High Pressure Water Jet And Compressed Air Blower. Applybond Coat A Water Miscible Epoxy Named As Kelox R 101 + Kelox H 404Of Dimple Chemicals & Services Pvt. Ltd. ( Using Manual / Mechanical Means ) Before Picc Application, It Ensure Strong Adhesion With Old Surface To New Picc Mortar. After Picc Apply A Poly Ceramic Cementitious Top Coat I.E Niccoat Pc + Kelmer A 60Of Dimple Chemicals & Services Pvt. Ltd After Finishing, After Top Coat Application, Pcc Will Be Done Up To 50 Mmthickness ( Or As Per Site Condition ) Of Desire Slope To Drain The Water And Kept Ponded For Continuous Period Of 3 Days To Detect Any Seepage / Leakage / Dampness If Any, The Surface Then Shall Be Cleared, Complete As Per Specification Including Cost Of All Materials, Machinery, Labour, Scaffolding, Insurance Chargesas Directed By The Engineer In Charge. , Providing & Applying Impermeable, High Compressive Strength, Monolithic Application, Excellent Bond Strength, High Abrasion Resistance, Uv Resistance, Self-Curing, Non-Toxic Polymer Based Cementitious Mortar Named Aspoly Ironite Ceramic Cementitious ( Picc ) Of Dimple Chemicals & Services Pvt. Ltd. Which Consists Of Nicomix Series + 53 Grade Cement + Water For Resurfacing Of Concrete Surfaces To A Thickness Upto 10 Mm Or As Per Surface Conditions Etc. Cleaning Will Be Done By Remove All Loose Particles, Dust Particles Or Any Other Foreign Material / Particles Using Manual Or Mechanical Means. After That, Clean The Concrete Surface With Special Chemical Named As Steripure 10 Of Dimple Chemicals & Services Pvt. Ltd. For Removing Of Algae Fungi Followed By High Pressure Water Jet And Compressed Air Blower. Applybond Coat A Water Miscible Epoxy Named As Kelox R 101 + Kelox H 404Of Dimple Chemicals & Services Pvt. Ltd. ( Using Manual / Mechanical Means ) Before Picc Application, After Picc Apply A Poly Ceramic Cementitious Top Coat I.E Niccoat Pc + Kelmer A 60 Of Dimple Chemicals & Services Pvt. Ltd After Finishing It Ensure Strong Adhesion With Old Surface To New Picc Mortar. Complete As Per Specification Including Cost Of All Materials, Machinery, Labour, Insurance Chargesas Directed By The Engineer In Charge. , Providing & Grouting By Polyceramic Cementitious Of Dimple Chemicals & Services Pvt. Ltd. Which Consists Of Nicgrout G 06 + 53 Grade Cement + Water As Per Requirementto Reduce The Porosityof Concrete / Masonry Structure And To Increase The Strength Of Structure Usinggrouting Pipes, Grouting M / C, Mixer Etc And All Relevant Safety With All Leads And Lifts, Material, Machinery, Labour, Scaffolding Etc. Complete As Per Specification And As Directed By Engineer-In-Charge. , Removal Of Vegetation / Plants:- Removal Of Vegetation & Plants By Its Roots From The Entire Surface Of Bridge With Manual Or Mechanical Means. After Removal Of Vegetation & Plants, Roots Shall Be Treated With Special Chemical I.E. Steripure Mbt 20 Of Dimple Chemicals & Services Pvt. Ltd. Top 50 Mm Shall Filled With High Strength Grout ( Nicgrout G 06Ofdimple Chemicals & Services Pvt. Ltd+ Cement 53 Grade ) Including Cost Of All Material, Machinery, Labour, Scaffolding, Etc.As Per Specification And As Directed By Engineer-In-Charge. , Providing & Applyingduraclean- Wris An Organic Polymer For Conversion Of Unwanted Substrate ( Burr ) On Metal Surface Crystal Structure Modification To Remove Oxide By High Pressure Waterjet Cleaning / Grinding, Wire Brush, Washing Or Mopping Also Removing Loose Particles ( Using Other Mechanical / Manual Means ) . Measure The Burr On The Surface By Burr Measuring Gauge, If The Burr Is Above 25 Microns Repeat The Cleaning Till Burr Is Below 25 Microns. Apply Duracap Is A Unique One-Pack Cold Metalizing Process Consisting Of Blend Of Active Ceramic, Alumina And Modified Polymer. Duracap Forms A Dot Matrix Coating On The Surface, Which Gives Better Adhesion With Substrates. Apply 2 Coats With A Thickness Upto 40 Micron On Prepared Metal Surface. Duracap Ensures Good Corrosion Resistance, Its A Weldable Primer Also Work As A Uv Reflector Etc. As Per Manufacturers Specification ( Using Other Manual / Mechanical Means ) . After Primer Application Base Coat Is Done Which Is Named As Duraguard A 3 Pack System , This Is A Blend Of Water Miscible Epoxy Andgives Properties Like Ant Rodent, High Corrosion Resistance, Chemical Resistance As Well As High Abrasion & Impact Resistance Etc.As Per Manufacturers Specification ( Using Other Manual / Mechanical Means ) Complete As Per Specification Including Cost Of All Materials, Machinery, Labour, Insurance Chargesas Directed By The Engineer In Charge. , Providing & Applying Impermeable, High Compressive Strength, Monolithic Application, Excellent Bond Strength, High Abrasion Resistance, Uv Resistance, Self-Curing, Non-Toxic Polymer Based Cementitious Mortar Named Aspoly Ironite Ceramic Cementitious ( Picc ) Of Dimple Chemicals & Services Pvt. Ltd. Which Consists Of Nicomix Series + 53 Grade Cement + Water For Resurfacing Of Concrete Surfaces To A Thickness Upto 10 Mm Or As Per Surface Conditions And Also Treatment Of Honey Combing Areas, Lift Jointsetc. Cleaning Will Be Done By Remove All Loose Particles, Dust Particles Or Any Other Foreign Material / Particles Using Manual Or Mechanical Means. After That, Clean The Concrete Surface With Special Chemical Named As Steripure 10 Of Dimple Chemicals & Services Pvt. Ltd. For Removing Of Algae Fungi Followed By High Pressure Water Jet And Compressed Air Blower. Applybond Coat A Water Miscible Epoxy Named As Kelox R 101 + Kelox H 404 Of Dimple Chemicals & Services Pvt. Ltd. ( Using Manual / Mechanical Means ) Before Picc Application, It Ensure Strong Adhesion With Old Surface To New Picc Mortar. Complete As Per Specification Including Cost Of All Materials, Machinery, Labour, Scaffolding, Insurance Chargesas Directed By The Engineer In Charge. , Providing & Applying Impermeable, High Compressive Strength, Monolithic Application, Excellent Bond Strength, Anti-Skid, High Abrasion Resistance, Uv Resistance, Self-Curing, Non-Toxic Polymer Based Cementitious Mortar Named Aspoly Ironite Ceramic Cementitious ( Picc ) Of Dimple Chemicals & Services Pvt. Ltd. Which Consists Of Nicomix Series + 53 Grade Cement + Water For Resurfacing Of Concrete Road Surfaces To A Thickness Upto 15 Mm Or As Per Surface Conditions And Also Treatment Of Pot Holes, Cracksetc. Cleaning Will Be Done By Remove All Loose Particles, Dust Particles Or Any Other Foreign Material / Particles Using Breaker, Wire Brush, High Pressure Water Jet, Compressed Air Jet ( Manual Or Mechanical Means ) . Applybond Coat A Water Miscible Epoxy Named As Keloxr 101 + Kelox H 404 Of Dimple Chemicals & Services Pvt. Ltd. ( Using Manual / Mechanical Means ) Before Picc Application, It Ensure Strong Adhesion With Old Surface To New Picc Mortar.Complete As Per Specification Including Cost Of All Materials, Machinery, Labour, Insurance Chargesas Directed By The Engineer In Charge. , Providing & Applying Impermeable, High Compressive Strength, Monolithic Application, Excellent Bond Strength, Anti-Skid, High Abrasion Resistance, Uv Resistance, Self-Curing, Non-Toxic Polymer Based Cementitious Mortar Named Aspoly Ironite Ceramic Cementitious ( Picc ) Of Dimple Chemicals & Services Pvt. Ltd. Which Consists Of Nicomix Series + 53 Grade Cement + Water For Resurfacing Of Concrete Surfaces To A Thickness Upto 25 Mm Or As Per Surface Conditions And Also Treatment Of Honey Combing Areas Etc. Cleaning Will Be Done By Remove All Loose Particles, Dust Particles Or Any Other Foreign Material / Particles Using Breaker, Wire Brush, High Pressure Water Jet, Compressed Air Jet ( Manual Or Mechanical Means ) . Applybond Coat A Water Miscible Epoxy Named As Keloxr 101 + Kelox H 404 Of Dimple Chemicals & Services Pvt. Ltd. ( Using Manual / Mechanical Means ) Before Picc Application, It Ensure Strong Adhesion With Old Surface To New Picc Mortar.Complete As Per Specification Including Cost Of All Materials, Machinery, Labour, Insurance Chargesas Directed By The Engineer In Charge. , Providing And Applying Poly Ironite Ceramic Cementitious ( Picc ) Ofdimple Chemicals & Services Pvt. Ltd Ensure Self Curing, High Abrasion Resistant, Non-Shrink, High Compressive Strength, Low Porosity, Uv Resistant Coating Mortar On Existing Well Gsb Of 100 Mm Thickness, Get Compacted Andlevelled , Cure The Surfacethen Applyingself Curing Coating Picc Mortarin Properation Of 1;1 ( Nicomix Series : Metal ) For 50 Mm Thickness After Stamp The Surface By Special Concrete Stamping Mould As Per Specified Texture And Colour Etc. Next Day Apply Finish Coat Of Kelmer A60 Of Dimple Chemical & Services Pvt. Ltd Complete With All Leads And Lifts, Material, Machinery, Labour Etc. Complete As Per Specification And As Directed By Engineer-In-Charge. ( Note- Gsb , Colour & Stamping Rates Not Included In This Ra ) , Masonry Bridge Repair Work:- Providing & Applying Impermeable, High Compressive Strength, Monolithic Application, Excellent Bond Strength, Anti-Skid, High Abrasion Resistance, Uv Resistance, Self-Curing, Non-Toxic Polymer Based Cementitious Mortar Named Aspoly Ironite Ceramic Cementitious ( Picc ) Of Dimple Chemicals & Services Pvt. Ltd. Which Consists Of Nicomix Series + 53 Grade Cement + Water For T-Pointing To A Depthupto 50 Mm Or As Per Surface Conditions And Raised On Stone Etc. Cleaning Will Be Done By Remove All Loose Particles, Dust Particles Or Any Other Foreign Material / Particles Using Manual Or Mechanical Means. After That, Clean The Joints With Special Chemical Named As Steripure 10 Of Dimple Chemicals & Services Pvt. Ltd. For Removing Of Algae Fungi Followed By High Pressure Water Jet And Compressed Air Blower. Applybond Coat A Water Miscible Epoxy Named As Kelox R 101 + Kelox H 404 Of Dimple Chemicals & Services Pvt. Ltd. ( Using Manual / Mechanical Means ) Before Picc Application, It Ensure Strong Adhesion With Old Surface To New Picc Mortar. Top Coat Will Be Done With Kelmer A 60 + Niccoat Pc On Picc To Seal The Surface And Reduce The Porosity Etc Complete As Per Specification Including Cost Of All Material, Machinery, Labour, Scaffolding, Transportation Etc. With All Leads And Lifts As Directed By The Engineer-In-Charge. , Providing & Grouting By Polyceramic Cementitious Of Dimple Chemicals & Services Pvt. Ltd. Which Consists Of Nicgrout G 06 + 53 Grade Cement + Water As Per Requirementto Reduce The Porosityof Concrete / Masonry Structure And To Increase The Strength Of Structure Usinggrouting Pipes, Grouting M / C, Mixer Etc And All Relevant Safety With All Leads And Lifts, Material, Machinery, Labour, Scaffolding Etc. Complete As Per Specification And As Directed By Engineer-In-Charge. , Removal Of Vegetation / Plants:- Removal Of Vegetation & Plants By Its Roots From The Entire Surface Of Bridge With Manual Or Mechanical Means. After Removal Of Vegetation & Plants, Roots Shall Be Treated With Special Chemical I.E. Steripure Mbt 20 Of Dimple Chemicals & Services Pvt. Ltd. Top 50 Mm Shall Filled With High Strength Grout ( Nicgrout G 06Ofdimple Chemicals & Services Pvt. Ltd+ Cement 53 Grade ) Including Cost Of All Material, Machinery, Labour, Scaffolding, Etc.As Per Specification And As Directed By Engineer-In-Charge. , Providing & Applyingduraclean- Wris An Organic Polymer For Conversion Of Unwanted Substrate ( Burr ) On Metal Surface Crystal Structure Modification To Remove Oxide By High Pressure Waterjet Cleaning / Grinding, Wire Brush, Washing Or Mopping Also Removing Loose Particles ( Using Other Mechanical / Manual Means ) . Measure The Burr On The Surface By Burr Measuring Gauge, If The Burr Is Above 25 Microns Repeat The Cleaning Till Burr Is Below 25 Microns. Apply Duracap Is A Unique One-Pack Cold Metalizing Process Consisting Of Blend Of Active Ceramic, Alumina And Modified Polymer. Duracap Forms A Dot Matrix Coating On The Surface, Which Gives Better Adhesion With Substrates. Apply 2 Coats With A Thickness Upto 40 Micron On Prepared Metal Surface. Duracap Ensures Good Corrosion Resistance, Its A Weldable Primer Also Work As A Uv Reflector Etc. As Per Manufacturers Specification ( Using Other Manual / Mechanical Means ) . Complete As Per Specification Including Cost Of All Materials, Machinery, Labour, Insurance Chargesas Directed By The Engineer In Charge. , Providing & Applying Impermeable, High Compressive Strength, Monolithic Application, Excellent Bond Strength, Anti-Skid, High Abrasion Resistance, Uv Resistance, Self-Curing, Non-Toxic Polymer Based Cementitious Mortar Named Aspoly Ironite Ceramic Cementitious ( Picc ) Of Dimple Chemicals & Services Pvt. Ltd. Which Consists Of Nicomix Series + 53 Grade Cement + Water For Filling Potholes For Concrete & Bitumen Roads To A Thickness Upto 75 Mm In A Ratio Of 1:1 ( Picc Mortar1 Part: Metal 6Mm 1Part ) Or As Per Surface Conditions And Also Treatment Of Honey Combing Areas Etc. Cleaning Will Be Done By Remove All Loose Particles, Dust Particles Or Any Other Foreign Material / Particles Using Breaker, Wire Brush, High Pressure Water Jet, Compressed Air Jet ( Manual Or Mechanical Means ) . Applybond Coat A Water Miscible Epoxy Named As Kelox R 101 + Kelox H 404Of Dimple Chemicals & Services Pvt. Ltd. ( Using Manual / Mechanical Means ) Before Picc Application, It Ensure Strong Adhesion With Old Surface To New Picc Mortar. Add Nikure 500 In To Above Morter For Normal Setting Of Dimple Chemicals & Services Pvt. Ltd. Complete As Per Specification Including Cost Of All Materials, Machinery, Labour, Insurance Chargesas Directed By The Engineer In Charge. , Providing & Applying Impermeable, High Compressive Strength, Monolithic Application, Excellent Bond Strength, Anti-Skid, High Abrasion Resistance, Uv Resistance, Self-Curing, Non-Toxic Polymer Based Cementitious Mortar Named Aspoly Ironite Ceramic Cementitious ( Picc ) Of Dimple Chemicals & Services Pvt. Ltd. Which Consists Of Nicomix Series + 53 Grade Cement + Water For Filling Potholes For Concrete & Bitumen Roads To A Thickness Upto 75 Mm Or As Per Surface Conditions And Also Treatment Of Honey Combing Areas Etc. Cleaning Will Be Done By Remove All Loose Particles, Dust Particles Or Any Other Foreign Material / Particles Using Breaker, Wire Brush, High Pressure Water Jet, Compressed Air Jet ( Manual Or Mechanical Means ) . Applybond Coat A Water Miscible Epoxy Named As Kelox R 101 + Kelox H 404Of Dimple Chemicals & Services Pvt. Ltd. ( Using Manual / Mechanical Means ) Before Picc Application, It Ensure Strong Adhesion With Old Surface To New Picc Mortar. Add Nikure 500 Of Dimple Chemicals & Services Pvt. Ltd. On Above Mortar Picc Will Be Ready To Traffic Load After 1 Hr Complete As Per Specification Including Cost Of All Materials, Machinery, Labour, Insurance Chargesas Directed By The Engineer In Charge. , Providing And Applying 30 Mm Thick Self Curing Ceramic Polymer Microconcrete Of Dimple Chemicals & Services Pvt. Ltd. Having Compressive Strength Above M30, Non Shrink, Impermeable, Filling Mortar In Cavities Like Beams, Column Etc. To Load Carrying R.C.C Member In One Or Two Layers ( Depending Upon The Site Condition ) On Cleaned Concrete Surface , Includinghoney Comb Area ( Using Manual / Mechanical Means ) . Mixingmortar Of Nicocil C80 And Fresh 53 Grade Cement With Required Water Cement Ratio For Desired Consistency And Applying And Finishing By Manual Trowelling , Curing After Curing Initial Setting Time Etc, As Per Manufacturers Specification Etc. Complete As Per Specification And As Directed By Engineer-In-Charge. , Providing And Applying Kelox R 101 ( Resin ) + Kelox H 404 ( Hardener ) A Water Miscible Epoxy Of Dimple Chemicals & Services Pvt. Ltd. For Bonding Old Concrete To New Picc Mortar, After Mixing Slowly In Predefined Ratio And Applying By Brush On The Surface. When It Is Tacky Then Apply The Picc Mortar Complete As Per Specification And As Directed By Engineer-In-Charge. , Providing & Applyingduraclean- Wr Of Dimple Chemicals & Services Pvt. Ltd. Is An Organic Polymer For Conversion Of Unwanted Substrate ( Burr ) On Metal Surface Crystal Structure Modification To Remove Oxide By High Pressure Waterjet Cleaning / Grinding, Wire Brush, Washing Or Mopping Also Removing Loose Particles ( Using Other Mechanical / Manual Means ) . Measure The Burr On The Surface By Burr Measuring Gauge, If The Burr Is Above 25 Microns Repeat The Cleaning Till Burr Is Below 25 Microns. Apply Duracap Of Dimple Chemicals & Services Pvt. Ltd. Is A Unique One-Pack Cold Metalizing Process Consisting Of Blend Of Active Ceramic, Alumina And Modified Polymer. Duracap Forms A Dot Matrix Coating On The Surface, Which Gives Better Adhesion With Substrates. Apply 2 Coats With A Thickness Upto 40 Micron On Prepared Metal Surface. Duracap Ensures Good Corrosion Resistance, Its A Weldable Primer Also Work As A Uv Reflector Etc. As Per Manufacturers Specification ( Using Other Manual / Mechanical Means ) . After Primer Application Base Coat Is Done Which Is Named As Duraguard A 3 Pack System Of Dimple Chemicals & Services Pvt. Ltd., This Is A Blend Of Water Miscible Epoxy Andgives Properties Like Ant Rodent, High Corrosion Resistance, Chemical Resistance As Well As High Abrasion & Impact Resistance Etc. Wrapping Will Be Done With Duramesh Of Dimple Chemicals & Services Pvt. Ltd. After 2 To 3 Hrs Of Wrapping Apply Final Coat Of Duraguard When Surface Is Tacky. This Coats Will Give The Thickness Approx. 350 Micron, As Per Manufacturers Specification ( Using Other Manual / Mechanical Means ) Complete As Per Specification Including Cost Of All Materials, Machinery, Labour, Insurance Chargesas Directed By The Engineer In Charge. , Providing & Applyingduraclean- Wr Of Dimple Chemicals & Services Pvt. Ltd. Is An Organic Polymer For Conversion Of Unwanted Substrate ( Burr ) On Metal Surface Crystal Structure Modification To Remove Oxide By High Pressure Waterjet Cleaning / Grinding, Wire Brush, Washing Or Mopping Also Removing Loose Particles ( Using Other Mechanical / Manual Means ) . Measure The Burr On The Surface By Burr Measuring Gauge, If The Burr Is Above 25 Microns Repeat The Cleaning Till Burr Is Below 25 Microns. Apply Duracap Of Dimple Chemicals & Services Pvt. Ltd. Is A Unique One-Pack Cold Metalizing Process Consisting Of Blend Of Active Ceramic, Alumina And Modified Polymer. Duracap Forms A Dot Matrix Coating On The Surface, Which Gives Better Adhesion With Substrates. Apply 2 Coats With A Thickness 40 Micron On Prepared Metal Surface. Duracap Ensures Good Corrosion Resistance, Its A Weldable Primer Also Work As A Uv Reflector Etc. As Per Manufacturers Specification ( Using Other Manual / Mechanical Means ) . After Primer Application Base Coating Is Done Which Is Named As Bituminous Epoxy Of Dimple Chemicals & Services Pvt. Ltd. A 2 Pack System, Kelox Rb5050 & Kelox Rh4040 This Is A Blend Of Rapid Setting Bitumen Emulsion And Water Miscible Epoxy I.E. Modified Epoxy Resin And Special Hardener. Wrapping Will Be Done With Duramesh Of Dimple Chemicals & Services Pvt. Ltd. Gives Properties Like Ant Rodent, High Corrosion Resistance, Chemical Resistance As Well As Abrasion & Impact Resistance Followed By Top Coat With Bituminous Epoxy. This Coating Gives Better Performance As Compare To Coatings Specified In Is 10221 . Apply 2 Coats With A Thickness 1Mm ( Bituminous Epoxy + Duramesh+ Bituminous Epoxy ) As Per Manufacturers Specification ( Using Other Manual / Mechanical Means ) Complete As Per Specification Including Cost Of All Materials, Machinery, Labour, Insurance Chargesas Directed By The Engineer In Charge. , Providing & Applyingduraclean- Wr Of Dimple Chemicals & Services Pvt. Ltd. Is An Organic Polymer For Conversion Of Unwanted Substrate ( Burr ) On Metal Surface Crystal Structure Modification To Remove Oxide By High Pressure Waterjet Cleaning / Grinding, Wire Brush, Washing Or Mopping Also Removing Loose Particles ( Using Other Mechanical / Manual Means ) . Measure The Burr On The Surface By Burr Measuring Gauge, If The Burr Is Above 25 Microns Repeat The Cleaning Till Burr Is Below 25 Microns. Apply Duracap Of Dimple Chemicals & Services Pvt. Ltd. Is A Unique One-Pack Cold Metalizing Process Consisting Of Blend Of Active Ceramic, Alumina And Modified Polymer. Duracap Forms A Dot Matrix Coating On The Surface, Which Gives Better Adhesion With Substrates. Apply 2 Coats With A Thickness 40 Micron On Prepared Metal Surface. Duracap Ensures Good Corrosion Resistance, Its A Weldable Primer Also Work As A Uv Reflector Etc. As Per Manufacturers Specification ( Using Other Manual / Mechanical Means ) After Primer Application Final Coating Is Done Which Is Named As Bituminous Epoxy Of Dimple Chemicals & Services Pvt. Ltd. A 2 Pack System Kelox Rb 5050 Kelox Rh 4040, This Is A Blend Of Rapid Setting Bitumen Emulsion And Water Miscible Epoxy I.E. Modified Epoxy Resin And Special Hardener. Apply 2 Coats With A Thickness Of 300 Micron On Prepared Metal Surface Etc. It Gives Properties Like Ant Rodent, High Corrosion Resistance, Chemical Resistance As Well As High Abrasion & Impact Resistance, Corrosion Protection Etc. As Per Manufacturers Specification ( Using Other Manual / Mechanical Means ) Complete As Per Specification Including Cost Of All Materials, Machinery, Labour, Insurance Chargesas Directed By The Engineer In Charge. , Providing & Applyingduraclean- Wr Of Dimple Chemicals & Services Pvt. Ltd. Is An Organic Polymer For Conversion Of Unwanted Substrate ( Burr ) On Metal Surface Crystal Structure Modification To Remove Oxide By High Pressure Waterjet Cleaning / Grinding, Wire Brush, Washing Or Mopping Also Removing Loose Particles ( Using Other Mechanical / Manual Means ) . Measure The Burr On The Surface By Burr Measuring Gauge, If The Burr Is Above 25 Microns Repeat The Cleaning Till Burr Is Below 25 Microns. Apply Duracap Of Dimple Chemicals & Services Pvt. Ltd. Is A Unique One-Pack Cold Metalizing Process Consisting Of Blend Of Active Ceramic, Alumina And Modified Polymer. Duracap Forms A Dot Matrix Coating On The Surface, Which Gives Better Adhesion With Substrates. Apply 2 Coats With A Thickness Upto 40 Micron On Prepared Metal Surface . Duracap Ensures Good Corrosion Resistance, Its A Weldable Primer Also Work As A Uv Reflector Etc. Also Reduces Frictional Resistance To Flow Of Water. As Per Manufacturers Specification ( Using Other Manual / Mechanical Means ) Complete As Per Specification Including Cost Of All Materials, Machinery, Labour, Insurance Chargesas Directed By The Engineer In Charge. , Water Proofing Of Swimming Pool -- Providing And Applying Impermeable, Monolithic Application, Uv Resistant, Self Curing, Non Toxic, High Compressive Strength, Non Shrink, Polymer Based Cementitious Waterproofing Mortar Named As Poly Ironite Ceramic Cementitious ( Picc ) Which Consists Of Nicomix Series + 53 Grade Cement + Water Of Dimple Chemicals & Services Pvt. Ltd.For Resurfacing The Concrete Surfaces Of Swimming Pool To A Thickness Upto 10 Mm Or As Per Surface Condition And Also Treatment Of Lift Joints And Honey Combing Areas, Potholes Etc. By Removing Loose Material, Dust Particles, Grout Slurry By Breaking It With Manual / Mechanical Means. Removing Of Existing Embedded M.S. Bar If Any, Cleaning The Lift Joints, Honey Combing Areas And Entire Surface With Special Chemical Named As Steripure 10 Of Dimple Chemicals & Services Pvt. Ltd. For Removal Of Algae - Fungi Followed With High Pressure Water Jet. Apply Bond Coat Named As Kelox R 101 + Kelox H 404Which Is Water Miscible Epoxy Of Dimple Chemicals & Services Pvt. Ltd. Before Picc Application For Suitable Bond Between Old Surface To New Picc Mortar And Then Do The Picc Application Providing With Top Coat Of Niccoat Pc + Kelmer A 60 Of Dimple Chemicals & Services Pvt. Ltd. After Finishing, Complete As Per Specification Including Materials, Machinery, Labour , Insurance Charges Transportation With All Leads And Lifts As Directed By The Engineer In Charge , Providing And Applying Durabond Of Dimple Chemicals & Services Pvt. Ltd. Is A Unique Blend Of Organic And Inorganic Materials Consisting Ceramic Ironite, Active Ceramic, Cement And Water Miscible Modified Epoxy. As This Contain Water Miscible Epoxy, Can Be Applied On Wet Surface With Better Bond Strength Between Old Concrete And Waterproofing Coating Material For External Surface Of Building. Crack Filling Will Be Done By Duraguardof Dimple Chemicals & Services Pvt. Ltd, Having Cold Weldling Properties Which Cn Stick Anything To Anything. Surface Cleaning Is Done To Remove Loose Material, Dust Particles By Breaking Using Manual And / Or Mechanical Means, Cleaning The Cracks, Small Potholes And Surface Preparation Will Be Done With Special Chemical Name Steripure 10Of Dimple Chemicals & Services Pvt. Ltd For Algae- Fungi Removal And Then Clean It With High Pressure Water Jet, Then Applying A Durabond Of 2 Coats A Special Type Of Coat Suitable To Bond Old To New Concrete Finishing, Complete As Per Specification Including Materials, Machinery, Labour, Scaffolding , Insurance Charges Transportation With All Leads And Lifts As Directed By The Engineer In Charge , Providing And Applying Duraclean Od Of Dimple Chemicals & Services Pvt. Ltd. Is An Organic Polymer For Emulsification & Dispersion Of Oil And Grease Spilled On Any Surface ( Concrete, Metal Or Water ) .Apply By Brush Or Spray On The Surface To Be Cleaned, Wait For About 5 – 10 Minutes, Wash The Surface With High Water Presure Jet.Repeat Process For Heavy Spillage And Surfaces Soaked In Oil Till It Is De-Oiled. Wait For 24 Hrs And See Whether The Penetrated Oil Comes Out To The Outer Surface, If Yes Then Repeat The Step 2-4. Complete As Per Specification Including Materials, Machinery, Labour, Insurance Charges Transportation With All Leads And Lifts As Directed By The Engineer In Charge , Water Proofing Of Water Tank -- Providing And Applying Impermeable, Uv Resistant, Self Curing, Non Toxic, High Strength, Non Shrink, Polymer Based Cementitious Waterproofing Mortar Named As Poly Ironite Ceramic Cementitious ( Picc ) Of Dimple Chemicals & Services Pvt. Ltd. Which Consists Of Nicomix Series + 53 Grade Cement + Water For Resurfacing Of Concrete Surfaces Of Water Tank To A Thickness Upto 5 Mm Or As Per Surface Conditions And Also Treatment Of Lift Joints And Honey Combing Areas, Potholes Etc. Is To Be Done With Picc By Removing Loose Material, Dust Particles, By Breaking Using Manual And / Or Mechanical Means, Removing Of Existing Embedded M.S. Bar If Any, Cleaning Of Lift Joints, Honey Combing Areas And Surface Is To Be Done Using Special Chemical Named Steripure 10 Of Dimple Chemicals & Services Pvt. Ltd. For Algae- Fungi Removal Followed By Compressed Water Jet. Apply Primer Coat Name Kelox R 101 + Kelox H 404 A Water Miscible Epoxy Of Dimple Chemicals And Services Pvt. Ltd. Before Picc Application. Kelox Is A Bonding Agent Between Old To New Concrete Mortar. Top Coat Will Be Done With Niccoat Pc + Kelmer A 60 Of Dimple Chemicals & Services Pvt. Ltd., Complete As Per Specification Including Materials, Machinery, Labour, Insurance Charges Transportation With All Leads And Lifts As Directed By The Engineer In Charge , Impermeable, Anti-Wear Coating On Concrete & Bitumen Road :- Providing And Applying Bituminous Epoxy Coating Of Dimple Chemicals & Services Pvt. Ltd. Having High Abrasion Resistant, Anti-Skid, Impermeable, Non Shrink, High Compressive Strength, For Concrete And Bitumen Road Coating Etc. Including Cleaning Of Concrete / Bitumen Road Surface By Wire Brush, Water Jet, Air Blower Etc. ( Using Other Mechanical / Manual Means ) To Remove Existing Loose Particles, Dirt Etc. Then Do Bituminous Coating By Taking Kelox Rb 5050 Of Dimple Chemicals & Services Pvt. Ltd.In A Clean Container & Add Kelox Rh 4040 Of Dimple Chemicals & Services Pvt. Ltd.In It, Apply This Mixture By Wiper On The Cleaned Surface.Top Coat Is Done Using Ready To Use Product I.E. Nicomix Butacoat Of Dimple Chemicals & Services Pvt. Ltd. , After Bituminous Epoxy Coating Immediately Sprinkle Nicomix Butacoat On Bituminous Epoxy Coating To Provide Impermeable, Antiwear & Antiskid Surface. After 10-15 Min, Use Roller On Top Coat I.E. On Nicomix Butacoatfor Compaction. After 6 Hours, Coated Surface Is Ready To Take The Load Of Traffic Movement, Complete With All Leads And Lifts, Material, Machinery, Labour Etc. Complete As Per Specification And As Directed By Engineer-In-Charge. , Providing And Applying Bituminous Epoxy Coating Of Dimple Chemicals & Services Pvt. Ltd. An Impermeable, Excellent Bonding With Old Surface, Non Shrink Repair Coating For Concrete Terrace & Etp Plants Includs & Steel Structurebituminous Coating By Taking Kelox Rb 5050 In A Clean Container & Add Kelox Rh 4040 In It, Stirr Well To Get Homogeneous Mixture, Apply This Mixture By Brush Type Wiper On The Cleaned Surface I, E Dust And Loose Partical Free, No Algae Fungi, Non Oily Surface, Corrosion Free Etc. Bituminious Epoxy Coating Is A Two Pack System Consist Of Kelox Rb 5050 Is A Blend Of Bitumen Emulsion With Epoxy Resin And Kelox H 404 Is A Modified Hardener.It Ensures Strong Adhesion With Any Substrate Like Concrete Road, Bituminous Road, Metal, Wood Etc. Complete With All Leads And Lifts, Material, Machinery, Labour Etc. Complete As Per Specification And As Directed By Engineer-In-Charge. , Providing& Applyinghigh Abrasive Resistant, Impermeable , High Strength, Non Shrink, Self Curing Poly Ironite Ceramic Cementatious ( Picc ) Of Dimple Chemical Services And Pvt Ltd, Which Consists Of Nicomix Series + 53 Grade Cement + Water I, E Piccmortar Mixing With Water Misible Epoxy I.E Kellox R 101 + Kelox H 404 Of Dimple Chemical Services And Pvt Ltdin The Ratio Of 80:20 ( Picc:Epoxy ) And Fill Thecracksfor 10 Mm Width & 10 Mm Depth With 1 Rmt Lengthon The Concrete Surface Ofroad, Industrial Floor Etc, Including Cleaning Of Cracks ( Using Manual / Mechanical Means ) , Power Tool Cleaning, Clean With Special Chemical Steripure 10 Of Dimple Chemical Services And Pvt Ltd For Alge Fungi Removal & Duraclean Od Of Dimple Chemical Services And Pvt Ltd For Oil Removalwith High Pressure Water Jet, Apply Bond Coat Of Water Misible Epoxy Of Keloxbefore Picc:Epoxy Application And Finishing, Complete As Per Specification Including Cost Of All Materials, Machinery, Labour, Insurance Charges Transportation With All Leads And Lifts And Any Other Incidental Charges As Directed By The Engineer In Charge. ( As Per Data Rate ) , Providing And Applying Duraclean Wr Of Dimple Chemicals & Services Pvt. Ltd. An Organic Polymer For Conversion Of Unwanted Substrate ( Burr ) On Metal Surface Crystal Structure Modification To Remove Oxide By Washing Or Mopping. Mesure Burr On The Surface, Spray Duraclean Wr On Surface To Be Cleaned, Wait For 5-10 Min And Then Wash It Off With High Pressure Water Jet. Again Mesure Burr On The Surface, Repeat The Process Till Burr Is Below 25 Micron Or 10% Of The Orignal Burr. Complete As Per Specification Including Materials, Machinery, Labour, Insurance Charges Transportation With All Leads And Lifts As Directed By The Engineer In Charge , Providing And Applying Clonon Of Dimple Chemicals & Services Pvt. Ltd. Clonon Is A Revolutionary Product Forbroad Spectrum Odour Remover.Clonon Contains A Proprietary Combination With Major Ingredilents Like Active Lodophor Solution, Benzalkonium Chloride Glutaraldhyde And Others, Clonon Product Main Features Of Odour Remover, No Added Fragrance , Debonds Nano Particles From Surface, Bacteria Killer, Quik Action, Non Toxic Chemicals, Ready To Use, No Stain And Residue , Does Not Contain Formaldehyde, Biodegradable Environmental Friendly.Complete As Per Specification Including Materials, Machinery, Labour, Insurance Charges Transportation With All Leads And Lifts As Directed By The Engineer In Charge , Providing And Laying In Situ Cement Concrete M -30 With Tremix Treatment For 200 Mm Thickness For Concrete Road With Uniform Sprinklingthe Nicocil R 90 Of Dimple Chemicals & Services Pvt. Ltd Using Travelfor Surface Hardening , High Abrasion Resistance And Low Porosity.Also Is Includinglaying Plastic Sheet For 125 Micron Thickness With Groove Cutting Of 4 Mm Wide And 20 Mm Deep With Necessary Refilling With Polysulphidesealant ( Pouring Grade ) Confirming To Bs : 5212 - 1989 Into Sawed Groove Widened At Top For Sealant Reservoir Of Specified Size And Shape As Per Detailed Drawing Including Fixing Polyethylene Foam Backer Rod Of Required Diameter ( Excluding Reinforcement ) With Coarsen And Fine Aggregate Using V.S.I.Qualityartificial Sand Etc. Complete As Per Specification Including Cost Of All Materials, Machinery, Labour, Insurance Charges As Directed By The Engineer In Charge. ( Note- Construction Of Concrete Road As Per Instruction Of Engineer-In-Charge Or Requirement, Rate Of Construction Not Included ) , Providing And Applying Steripure S 30 Of Dimple Chemicals & Services Pvt. Ltd. Is Antibacterial, Antifungal Water Base Solution To Remove Algae-Fungi From Concrete , Masonry , Metal, Stone, Tile , Wood, Paver Block And All Composite Material Surface. Spray Steripure S 30 ( Prepar Dillusion In 1 Part Steripuri S30 : 9 Part Water ) On Surface To Be Cleaned, Wait For 15 - 20 Mins Then Wash The Surface With High Pressure Water Jet. This Unique Product Kills The Roots Of Algae-Fungi Which Can Be Removed From Surface By High Pressure Water Jet Cleaning. Re-Growth Of Algae-Fungi Is Stopped Due To Removal Of Roots. Complete As Per Specification Including Materials, Machinery, Labour, Insurance Charges Transportation With All Leads And Lifts As Directed By The Engineer In Charge. , Providing And Laying Of Rumble Strip Usingplastirib 2K 2 Component Cold Plastic Road Marking Material In Single Monolithic Application To Create Rumble Strip Raised Section 15 Mm - 20 Mm High , 200 To 300 Mm Wide And Spaced About 1 Meter Centre To Centre Of Roughly 6 Numbers At One Location, Across The Entire Carriageway. Each Rumble Marking Shall Be Made Complete With Drop On Solid Plus Reflective Glass Beads @ 350 Gm / Sqm Spread Throughout The Surface Of Marking. The Finished Surface Shall Be Levelled, Uniform , Free From Straks And Holes Including Surface Cleaning And Cost Of All Materials Etc. Complete. As Per Irc 99, These Rumble Strips Shall Be Applied As Traffic Calming Measure. , Kerb Stone / Vertical Surface Painting With Reflective Paint, Make Grade 1 ( As Per Is 164 ) Water Based Acrylic Paint, Preferably Mechnical Application For One Coat Priming Coat And 1 Uniform Retro Reflective Finish Coat In Required Colour. Yellow Retroreflecive Coat Shall Be Bright Yellow During Night With Minimum Rl ( Dry ) > 375 Mcd / M2 / Lux White Retroreflective Coat Shall Be Bright White During Night With Minium Rl ( Dry ) > 450 Mcd / M2 / Lux .Cleaning Of The Surface Thoroughly By Removing Flakes, Dust Deposits, Vegetation Growth, Pasted Paper Etc., Using Coir / Coil Brush, So As To Enable The Application Of Respective Primer Etc. , Providing And Applying 2 Component Cold Plastic Night Glow Paint Rolled On Surfacing Material Solvent Free, High Build Two Pack Seamless, Tough, Skid Resistant, Material Which Has Property Of Attaining 600 Microns Thickness In Single Coat Application White ( Or As Required Colour ) Based On Glass And Colour Retaining Acralic Cross Linking Resin System For Coloured Road Surfacing Including Surface Cleaning And Cost Of All Material Etc. Complete. ( All Inclusive On Bitumen Or Concrete Surface ) Night Glow Paint Shall Preferably Be Roller Applied. After Glow Finish Surface Shall Provide Minimum Of 8 Hrs Glow After Fully Absorbing Ambient Light ( Visibile Light Or Uv Light ) For 15 - 30 Min. Cleaning Of The Surface Thoroughly By Removing Flakes, Dust Deposits, Vegetation Growth, Pasted Paper Etc., Using Coir / Coil Brush, So As To Enable The Application Of Respective Primer Etc. , Augmented Wet Reflective Dot ( Awrd ) Marking System On Awrd On - Bituminous Surface Component Cold Plastic Road Marking Primer Supply And Application Awrd Road Marking System With Minimum Of 50% Of The Intended Road Marking The Surface Area To Be Covered With Dots Of Thickness Of 5+1 Mm, Each Dot Having Dia. Of 25 + 5 Mm Using Plastidot 2K 2 Component Cold Plastic Road Marking Material And Solid Plus 100 Drop Of Glass Beads With Ri 1.6. Performance Parameters Shall Comply With Rl Dry > 800 Mcd / Sqm / Lux & Rl Wet > 250 Mcd / Sqm / Lux , Measured Using Zehntner Gmbh / Esylux / Delta Make Reflectometer In Case Of Concrete / Worn Out Bituminous Surfaces Application Of 2 Component Cold Plastic Road Marking Primer Is Mandatory. , Augmented Wet Reflective Dot ( Awrd ) Marking System On Awrd On- Concrete Surface With Application Of Special 2 Component Cold Plastic Road Marking Primer Supply And Application Awrd Road Marking System With Minimum Of 50% Of The Intended Road Marking The Surface Area To Be Covered With Dots Of Thickness Of 5+1 Mm, Each Dot Having Dia. Of 25 + 5 Mm Using Plastidot 2K 2 Component Cold Plastic Road Marking Material And Solid Plus 100 Drop Of Glass Beads With Ri 1.6. Performance Parameters Shall Comply With Rl Dry > 800 Mcd / Sqm / Lux & Rl Wet > 250 Mcd / Sqm / Lux , Measured Using Zehntner Gmbh / Esylux / Delta Make Reflectometer In Case Of Concrete / Worn Out Bituminous Surfaces Application Of 2 Component Cold Plastic Road Marking Primer Is Mandatory. , Supplying And Fixing Of High Performance Moulded Shank Raised Pavement Marker / Cats Eye Made Of Reinforced Polycarbonate And Weather Protected Ip > 68 Abs Moulded Body Having 2 Compartment Scratch And Abrasion-Proof Prismatic Polycarbonate Lens Capable Of Providing A Total Internal Reflection Of The Light Entering The Lens Face And Shall Support A Load Per Wheel ( Per Axle ) Of 20000 Kg And Per Axle 40000 Kg Tested In Accordance To Astm 4280D & En 1463-1 And En 1463-2 And Morth. The Dimensions Of The Pavement Marker Being 100 X 100 X 18 Mm And Weight 140Gm, Pin 55 Mm Depth Dia 13 Mm In Star Shape For Better Gripfixing Will Be By Drilling Holes On The Road For The Shank To Go Inside, Without Nails And Using Cold Plastic-Based Adhesive As Per Manufacturers Recommendation And Complete As Directed By The Engineer. The Contractor And Manufacturer Shall Submit A Minimum 1 Yr Installation Warranty And 2 Years Reflectivity Warranty For Satisfactory Field Performance. , Supplying And Fixing Of Solar Road Studs ( High Performance ) Polycarbonate Body, Pavement Surface Mounted Compliant Withen1463 Part 3 Havinguni-Direction Or Bi-Directional With Solar Powered Led Illumination And Reflective Panel Having 1 ) Dimensions 115 X 100 X 8.5 Mm 2 ) Marker Shall Support A Load Of 20 Ton Tested In Accordance To En 1463 . 3 ) Waterproof And Dust Protection Ip > 68 4 ) Weight 117 Gram 5 ) Fixing Using 2 Coponent Cold Plastic Based Adhesive / Butyl Tape Or As Reccomended By Manufacturer 6 ) Working Temperature: Up To 80 Deg. C 7 ) The Contractor And Manufacturer Shall Submit A Technical Warraty Of 1 Yr. , Providing And Fixing 8 Mm Tinted Tuffan Glass With Fitting Inaluminium Section Of Size 100 Mm X 763 Mm Also Including Door Glass With Ss Handle Of Size 1.2M Height And 50Mm O.D. And 30Mm I.D. And Ss Door Hinges Of Size 150Mm Height And 80Mm Width On One Face, Fitting Glass With Silicone Tube Including Scaffolding And Fitting Charges Etc. Complete & As Directed By Enginner Incharge , Providing Concrete Resurfacing System Of High Strength High Abrasion Resistant Deck Crs Base Coat And Deck Crs Top Coat Of Approved Color With Antiskid / Rough Texture And With Approved Stencil Pattern Following By Deck Sealer Final Coat, Including Providing Surface Preparation By Using Grinder Machine / Hand Grinders On Serrated / Slurried Concrete Surface To Expose Original Hard Concrete Surface And Washing Area Thoroughly Including Removal Of Nails Erc Complete. Surface Will Be Open To Traffic After 72 Hours Of Application Of Deck Crs. Deck Crs Consumption 3.8-4 Kg / Sqm , Providing Concrete Resurfacing System Of High Strength High Abrasion Resistant Deck Crs Base Coat And Deck Crs Top Coat Of Approved Color With Antiskid / Rough Texture Without Any Pattern ( Plain ) And Followed By Deck Sealer Final Coat, Including Providing Surface Preparation By Using Grinder Machine / Hand Grinders On Serrated / Slurried Concrete Surface To Expose Original Hard Concrete Surface And Washing Area Thoroughly Including Removal Of Nails Erc Complete. Surface Will Be Open To Traffic After 72 Hours Of Application Of Deck Crs. Deck Crs Consumption 3.8-4 Kg / Sqm , Providing And Fixing 50 Mm Thick Door Shutter Using 25 Block Board 10 Mm Ply On Either Side Of Block Board , 4 Mm Thick Veneer On One Side With Melamine Polish And 1 Mm Thick Laminate On Other Side , Ss Hinges ( Brass ) 125 Mm , Tower Bolt 380 Mm , Mortise Lock , Concealed Door Closer Including Necessary Teak Wood Bedding , Fevical , Screw & Labour For Fixing Etc Complete As Directed By Engineer In Charge , Providing And Fixing 50 Mm Thick Main Entrance Door Partly Panelled And Partly Glazed Door Using 25 Mm Block Board , 10 Mm Ply Garjan On Either Side , Teak Wood Beading Covered With On Side 4 Mm Thick Rich Veneer With Melamine Polish, Floor Spring , Concealed Lock , 1.2 M Handle Pair Of 25 Mm Dia , Glass Pannels Of 0.40 X 0.40 Including Necessary Fevicol , Nails Screw And Labour For Fixing Etc Complete , Providing And Fixing High Quality Inter Locking Concrete Cobble Stone Finish Pavers In Circular Form Having Area Of 1.218 Sqm ( Approximately 71 Or 74 Nos. In One Circle ) , Made By Using Rubber Moulds Of 60 Mm Thickness, Tested And Certified By Csir-Cbri Of Having Strength Of 500 Kg / Sqm. Pavers Should Have 10 Mm Face Layer In White Cement With Pigment Of Lanxess Or Tata Make And Base Mix In M40 Grade Concrete. The Pavers Should Be Made Available In Various Sizes To Make A Circle Of Approved Finish And Design Of Standard Make On A Bed Of Crushed Sand Of 25 To 30 Mm Thick Including Skirting Joints And Cleaning As Directed By Engineer Incharge Etc. Complete. Prior Approval Of Superintending Engineer Will Be Necessary . , Providing And Fixing Fiber Reinforced Cover To Inspection Chamber With Frame Of Fibrocast Or Equivalent Make Of Size600 Mm X 450 Mm Light Duty Withstand To Carry A Load Of 5.00 M.T. With 2 Years Warranty Issued From Company, Also Should Submit Test Report From Manufacturer Etc. Including All Labours, Accessories, Leads, Lifts And As Directed By Engineer In Charge. , Providing And Fixing Fiber Reinforced Cover To Inspection Chamber With Frame Of Fibrocast Or Equivalent Make Of Size 600 Mm X 450 Mm Medium Duty Withstand To Carry A Load Of 12.50 M.T. With 2 Years Warranty Issued From Company, Also Should Submit Test Report From Manufacturer Etc. Including All Labours, Accessories, Leads, Lifts And As Directed By Engineer In Charge. , Providing And Fixing Fiber Reinforced Cover To Inspection Chamber With Frame Of Fibrocast Or Equivalent Make Of Size 600 Mm X 450 Mm Heavy Duty Withstand To Carry A Load Of 25.00 M.T. With 2 Years Warranty Issued From Company, Also Should Submit Test Report From Manufacturer Etc. Including All Labours, Accessories, Leads, Lifts And As Directed By Engineer In Charge. , Providing And Fixing Fiber Reinforced Cover To Inspection Chamber With Frame Of Fibrocast Or Equivalent Make Of Size 900 X 600 Mm Light Duty Withstand To Carry A Load Of 5.00 M.T. With 2 Years Warranty Issued From Company, Also Should Submit Test Report From Manufacturer Etc. Including All Labours, Accessories, Leads, Lifts And As Directed By Engineer In Charge. , Providing And Fixing Fiber Reinforced Cover To Inspection Chamber With Frame Of Fibrocast Or Equivalent Make Of Size 900 X 600 Mm Medium Duty Withstand To Carry A Load Of 12.50 M.T. With 2 Years Warranty Issued From Company, Also Should Submit Test Report From Manufacturer Etc. Including All Labours, Accessories, Leads, Lifts And As Directed By Engineer In Charge. , Providing And Fixing Fiber Reinforced Cover To Inspection Chamber With Frame Of Fibrocast Or Equivalent Make Of Size 900 X 600 Mm Heavy Duty Withstand To Carry A Load Of 25.00 M.T. With 2 Years Warranty Issued From Company, Also Should Submit Test Report From Manufacturer Etc. Including All Labours, Accessories, Leads, Lifts And As Directed By Engineer In Charge. , Providing And Fixing Glass Bricks Of Size 190 Mm X 190 Mm X 80 Mm Fitted Inside Already Prepared Ss / Ms Fabrication Using Silicon Glass Sealant Before Placing Of Bricks And After Placing Of Bricks To Create A Bond Between Fabrication Material And Glass Bricks, Finishing The Surface By Filling The Gap Between Glass Bricks With White Cement Etc. Including Loading And Unloading Of The Material As Directed By Engineer In Charge. , Supply, Providing Manufacturing And Fixing Of Interchangeble Plates Of Assigned Designation Post And Room Of Office, Judges And Subordinate Of Organization Of Providing 5 Mm Blue Frp Sheet For Base Surface And 5 Mm Frp Sheet Laser Cutting Latter Of White Color With Measuring , Marking, Cutting, Finishing Also With Fixing Of Letter On Based Surface By A Solvent By Providing Latters Name In Required Language Style, Type Font Including Interchangeble System For Easily Changing Of Plates As Per The Requirement For Pleasent And Elegant Look With Screw And Grip As Per Requirement And Direction Etc Complete. ( Size-0.65M*0.35 ) . , Supply, Providing Manufacturing And Fixing Of Interchangeble Plates Of Assigned Designation Post And Room Of Office, Judges And Subordinate Of Organization Of Providing 5 Mm Blue Frp Sheet For Base Surface And 5 Mm Frp Sheet Laser Cutting Latter Of White Color With Measuring , Marking, Cutting, Finishing Also With Fixing Of Letter On Based Surface By A Solvent By Providing Latters Name In Required Language Style, Type Font Including Interchangeble System For Easily Changing Of Plates As Per The Requirement For Pleasent And Elegant Look With Screw And Grip As Per Requirement And Direction Etc Complete. ( Size-0.25M*0.35 ) . , Providing & Fixing Ester Resin Material 5Th Km Structure As Per Irc-08-1980 With Chopped Strand Mat 350 Micron Gsm With H2o2, Cobolt Octate ( 3% ) , With Pigment & All Required Allied Accessories Front & Back Side Bonded With Type Iv Retro Reflective Sheeting & Lettering Etc Complete. The Contractor Has To Provide Outerdoor Test Certificate Of Type Iv Reflective Sheeting From The Retro Reflective Manufacture. For Fixing Structure Excavation Of 0.75 X 0.75 X 0.45 Mtr. & Filling The Soil Inside The Bags & That Bags Filled In The Structure As Directed Engineer In-Charge Etc Complete , Providing & Fixing Ester Resin Material 1St Km Structure As Per Irc-08-1980 With Chopped Strand Mat 350 Micron Gsm With H2o2, Cobolt Octate ( 3% ) , With Pigment & All Required Allied Accessories Front & Back Side Bonded With Type Iv Retro Reflectivesheeting & Lettering Etc Complete. The Contractor Has To Provide Outerdoor Test Certificate Of Type Iv Reflective Sheeting From The Retro Reflective Manufacture. For Fixing Structure Excavation Of 0.75 X 0.75 X 0.45 Mtr. & Filling The Soil Inside The Bags & That Bags Filled In The Structure As Directed Engineer In-Charge Etc Complete , Providing & Fixing Ester Resin Material 200 Mtr Structure As Per Irc-26-1967 With Chopped Strand Mat 350 Micron Gsm With H2o2, Cobolt Octate ( 3% ) , With Pigment & All Required Allied Accessoriesfor Fixing Structure Excavation Of 0.60 X 0.60 X 0.45 Mtr. & Filling The Soil Inside The Bags & That Bags Filled In The Structure As Directed Engineer In-Charge Etc Complete , Milling Of Bituminous Pavement Upto Depth Of 50 Mm By Cold Milling Machine Including All Levelling And Slope Sensors, Self-Loading Of Milled Material By Discharge Conveyor Onto Transport Vehicle Including Lead Charges Of 10 Km As Directed By Engineer In Charge , Milling Of Bituminous Pavement Upto Depth Of 100 Mm By Cold Milling Machine Including All Levelling And Slope Sensors, Self-Loading Of Milled Material By Discharge Conveyor Onto Transport Vehicle Including Lead 10 Km As Directed By Engineer In Charge , Dismantling Of Rigid Concrete Pavement Upto Depth Of 50 Mm Using Cold Milling Machine Including All Levelling And Slope Sensors, Self-Loading Of Milled Material By Discharge Conveyor Onto Transport Vehicle Including Lead 10 Km As Directed By Engineer In Charge , Re-Texturing Of Rigid Concrete Pavement Upto Depth Of 20 Mm Using Cold Milling Machine With Fine Milling Drum Of Width 1.5M Or Above Including All Levelling And Slope Sensors, Self-Loading Of Milled Material By Discharge Conveyor Onto Transport Vehicle Including Lead 10 Km As Directed By Engineer In Charge , Providing And Fixing Stainless Steel ( Grade 304 ) Made Of Hollow Tubes, Channels, Plates Etc., Including Welding, Grinding, Buffing, Polishing And Making Curvature ( Wherever Required ) And Fitting The Same With Necessary Stainlesssteel Nuts And Bolts Complete, I / C Fixing The Railling With Necessary Accessories & Stainless Steel Dash Fasteners, Stainless Steel Bolts Etc., Of Required Size, On The Top Of The Floor Or The Side Of Waist Slab With Suitable Arrangement As Per Approval Of Engineer-In-Charge, ( For Payment Purpose Only Weight Of Stainless Steel Members Shall Be Considered Excluding Fixingh Accessories Such As Nuts, Bolts, Fasteners Etc. ) . , Providing Concrete Surfacing System With Deck Crs With Base Coat, Application Of Pattern In Stencil Followed By Top Coat And Sealer Including Surface Preparation Etc. Deck Crs Consumption About 4 Kg / Sqm As Per Manufacturers Specifications , Providing Concrete Surfacing System With Deck Crs With Base Coat Followed By Top Coat And Sealer Including Surface Preparation Etc. Deck Crs Consumption About 4 Kg / Sqm As Per Manufacturers Specifications , Providing And Fixing High Density Polypropylene Under Ground Water Tank Of Requiredsize With 5 Years Warranty Issued From Company, Also Shouldsubmit Test Report From Manufacturer Etc. Including All Labours, Accessories, Leads, Lifts And As Directed By Engineer In Charge ( From 1000 To 3000 Litre ) , Providing And Fixing High Density Polypropylene Under Ground Water Tank Of Requiredsize With 5 Years Warranty Issued From Company, Also Shouldsubmit Test Report From Manufacturer Etc. Including All Labours, Accessories, Leads, Lifts And As Directed By Engineer In Charge ( From 1000 To 3000 Litre ) , Providing And Fixingchevron Sign Boards In Rectangular Size Of 500X600 Mm Made Out Of ___Mm Aluminium Sheet Bonded With White Retro Reflective Sheeting Of Class B ( Type Iv High Intensity Micro-Prismatic Grade Sheeting -Hip ) Having Pressure Sensitive / Heat Activated Adhesive Retro Reflective Specified Background, Border And Back Side Retro Reflective Symbols, Letters, Numerals, Arrow As Per Irc 67-2012 Supported With Back Support Frame 25Mmx25mmx3mm, Duly Painted On Back Side With Grey Stove Enamel Paint And Supported On One No. Of M.S. Angle Iron Post Of 65Mmx65mmx6mm, 3.45 Mtr Long, Dully Painted With Flat Oil Paint Having Alternate Black And White Bands Of 25Cm Width Including G.I.Fixtures Etc. Fixing The Boards In M25 Grade Concrete Block Of Size 60Cm X 60Cm X 75Cm Including Transportation Etc. Complete.Class-B ( Type Iv High Intensity Micro Prismatic Grade Sheeting -Hip ) Shall Have 7 Years Writen Warranty From The Manufacturer Of The Retro Reflective Sheeting And Authorised Distributor / Converter Issued For Fiedl Performance Including The Screen Printed Area And Cut-Out Sheeting And Cut-Out From The Durable Transparent Overlay Film And This Warranty Certificate In Original & A Certified Copy Of 3 Year Outdoor Exposure Test Report From Third Party Test Lab For The Product Offered Shall Be Submitted By Contractor To Engineer Incharge. 500X600mmmade Out Of 3Mm Aluminium Composite Material With 0.25Mm Skin Thickness On Either Side , Providing And Fixing One Way Hazard Marker Sign Boards In Rectangular Size Of 300X900 Mm Made Out Of 4Mm Aluminium Sheet Bonded With White Retro Reflective Sheeting Of Class B ( Type Iv High Intensity Micro-Prismatic Grade Sheeting -Hip ) Having Pressure Sensitive / Heat Activated Adhesive Retro Reflective Specified Background, Border And Back Side Retro Reflective Symbols, Letters, Numerals, Arrow As Per Irc 67-2012 Supported With Back Support Frame 25Mmx25mmx3mm, Duly Painted On Back Side With Grey Stove Enamel Paint And Supported On One No. Of M.S. Angle Iron Post Of 65Mmx65mmx6mm, 1.8 Mtr Long, Dully Painted With Flat Oil Paint Having Alternate Black And White Bands Of 25Cm Width Including G.I.Fixtures Etc. Fixing The Boards In M25 Grade Concrete Block Of Size 60Cm X 60Cm X 75Cm Including Transportation Etc. Complete.Class-B ( Type Iv High Intensity Micro Prismatic Grade Sheeting -Hip ) Shall Have 7 Years Writen Warranty From The Manufacturer Of The Retro Reflective Sheeting And Authorised Distributor / Converter Issued For Fiedl Performance Including The Screen Printed Area And Cut-Out Sheeting And Cut-Out From The Durable Transparent Overlay Film And This Warranty Certificate In Original & A Certified Copy Of 3 Year Outdoor Exposure Test Report From Third Party Test Lab For The Product Offered Shall Be Submitted By Contractor To Engineer Incharge. 300X900mmmade Out Of 4Mm Aluminium Composite Material With 0.5Mm Skin Thickness On Either Side , Providing And Fixing Two Way Hazard Marker Sign Boards In Rectangular Size Of 450X900 Mm Made Out Of 4Mm Aluminium Sheet Bonded With White Retro Reflective Sheeting Of Class B ( Type Iv High Intensity Micro-Prismatic Grade Sheeting -Hip ) Having Pressure Sensitive / Heat Activated Adhesive Retro Reflective Specified Background, Border And Back Side Retro Reflective Symbols, Letters, Numerals, Arrow As Per Irc 67-2012 Supported With Back Support Frame 25Mmx25mmx3mm, Duly Painted On Back Side With Grey Stove Enamel Paint And Supported On One No. Of M.S. Angle Iron Post Of 65Mmx65mmx6mm, 1.8 Mtr Long, Dully Painted With Flat Oil Paint Having Alternate Black And White Bands Of 25Cm Width Including G.I.Fixtures Etc. Fixing The Boards In M25 Grade Concrete Block Of Size 60Cm X 60Cm X 75Cm Including Transportation Etc. Complete.Class-B ( Type Iv High Intensity Micro Prismatic Grade Sheeting -Hip ) Shall Have 7 Years Writen Warranty From The Manufacturer Of The Retro Reflective Sheeting And Authorised Distributor / Converter Issued For Fiedl Performance Including The Screen Printed Area And Cut-Out Sheeting And Cut-Out From The Durable Transparent Overlay Film And This Warranty Certificate In Original & A Certified Copy Of 3 Year Outdoor Exposure Test Report From Third Party Test Lab For The Product Offered Shall Be Submitted By Contractor To Engineer Incharge.450X900mmmade Out Of 4Mm Aluminium Composite Material With 0.5Mm Skin Thickness On Either Side , Providing And Fixing 8 Mm Tinted Tuffan Glass With Fitting Inaluminium Section Of Size 100 Mm X 763 Mm Also Including Door Glass With Ss Handle Of Size 1.2M Height And 50Mm O.D. And 30Mm I.D. And Ss Door Hinges Of Size 150Mm Height And 80Mm Width On One Face, Fitting Glass With Silicone Tube Including Scaffolding And Fitting Charges Etc. Complete & As Directed By Enginner Incharge , Encasement Of Columns And Beams By Placing 75 To 100 Mm Thick Free Flow High Strength Micro Concrete With Leak Proof Shuttering With All Equipments, Manpower Etc Complete , Providing And Applying Epoxy Mortar Epibond 11 In Areas Of Fixing Cracks, Charges For Repairing Of Full Depth Crack ( 30Mm Depth X 50Mm Width / Per Rmt ) On Pqc Pavement Using Cross Stitching Method As Per Specification Of Irc Sp : 83-2008. Making Chase Along Crack And Cleaning The Holes / Chase With Oil Free Compressed Air, Fixing Of Reinforcement In Holes Filled With Epoxy Resin In Enough Quantity For The Bar To Be Completely Coated When Inserted In The Hole, Chase Filling With Epoxy Epibond 11 ( 1:1:8 ) Resin+Hardner+Fine Sand As Per Manufacture Specification, Curing, Transportation, Required Machinery, Tool And Tackles Etc.Complete As Per Direction Of Eic. , Providing And Applying Volatile Corrosion Inhibiting Wax Powrthrow Ht Wax On Ht Lrpc Strands Before Embedment In Tendons, Lrpc Strands Of 12.7Mm & 15.2Mm , Tendon Duct Need To Be Lime Washed Prior To Insertion Of Lrpc Strands Coated With Wax. The Wax Must Be Hand Applied Using Gloves From The Pail Prior To Insertion On Strand In Duct. Powrthrow Ht Wax Is Bipolar In Nature Should Protect The Strand From Corrosion. As Per Jis Z 1535M Method Should Have Excellent Resistance To Corrosion Spots. And The Wax Should Show A Potential Change Of Minimum 120Mv As Per Corrosion Potential Test.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
Maharashtra View Result →
6.
Civil Aviation #10546587 Price Bid
Tender For Provision Of Guard Lights At Tuticorin Airport; 1 SITC of FAA/ICAO/DGCA-CAR compliant LED based Runway Guard lightfor compliance as per ICAO/DGCA-CAR aviation visual aids requirements complete with LED lamp/s with integral driver, electronics suitable for operation along with existing 2.8-6.6 Amps current Circuit & CCRs , with all accessories and cable lead with plug ready for site installation on circular Housing box ,suitable for all weather operation, conforming to latest ICAO / CAR requirement as per specifications complete as required. 2 Supply of45 W, 6.6A/6.6A rating 5000V, 50 Hz Series Isolating Transformers encapsulated in black cross linked polychloroprene compound like TPE /TPR / TPV with primary and secondary connections suitable to be operated confirming to specification as required suitable for above mentioned LED runway Guard light fittings complete as per Technical Specifications. 3 SITC of CI Adaptor / collar box round type of outside dia 330mm of 150mm height made of 10 mm thick cast iron moulding all round except on top surface which is 15 mm thick cast iron moulding suitable to receive a light fitting base plate on the top. The CI collar shall have a clear opening of 220 mm at the top and bottom surface and 6 nos M-10 tapped holes at the centre of 260 mm at top and bottom to fix the collar including providing 6 nos. M-10 bolts (SS) and a base. The cost shall include necessary bitumen/concrete kerf/core cutting and concrete works for fixing the same and laying of connceting pipes. 4 Installation of CI Transformer housing box with a base concrete of 1:3:6 of size 630*630*100mm thick all round concrete of 1:2:4, 150mm thick top sloped with 1:2:4 cemeny concrete including excavation of existing Bituminous Road/Pavement/shoulder of the runway, disposal of material within 50 mtrs lead, providing and fixing 300mm long 1/2 dia B class GI pipe with check nut for drainage of water including excavation of side shoulder and refilling. The boxes are aligned in such way that the hole centres fall in straight line etc., complete as required. 5 Supply of 2C x 4 sq.mm., 600V Grade Flexible Copper Conductor, EPR insulated & CPE (Chlorinated Polyethylen, cross - linked, heavy duty) outer sheath (Black colour) Secondary cable for Airport lighting circuits conforming as specified in particular specification sizes as required. 6 Supply and installation of 2 pin secondary plug suitable for connection of isolation transformer and to light fixture complete as required 7 Supply of plug & receptacle of size 6 sqmm type I, class B connector & suitable for attachment with 5 KV grade XLPE insulated PE sheathed single core screened copper conductor cable as required. 8 Laying of one number of PVC insulated and PVC sheathed cable of 5KV grade of following size in the existing RCC/ HUME/ METAL/HDPE pipe as required. 9 Providing and Laying of 25 mm dia B class GI Pipe in Runway for runway guard light fittings. Job Involve kerf cutting and refiling the same with (fast grouting) cement concrecting complete with threading and alignment of pipe with transformer housing box as required. 10 Supply offollwing size5 KV Grade stranded Copper Conductor single core PVC insulated, PVC sheathed, unshielded, anti-termite and rodent treated, airport lightingcable generally confirming to IS 1554- Part-II 1981 with up to date amendments and as specified in particular specifications of the following sizes as required. 1 Core X 6 Sq mm. 11 SITC ofIndoor, Air cooled Type constant current regulator of Thyristor Controlled microprocessor based suitable for use on 230V+ 10% volts, 50/60 Hz, Input AC Supply with Output Power of 7.5 KW at 6.6 Amps with 5 Steps variation of Current Output suitable for local and Remote Control Operation with 24/48 VDC integral Control Supply complete with output current indicated on multifuction digital display, over current, over voltagte, earth fault protection and earth leakage meter, positive feed back indication equipments,complete with 5 KV grade current transformer and relays, contactors interconnection with multicore control cable junction box etc complete as per AAI specifications as required. (The CCR should be supplied with modules connecting to available NASU make ALCMS system at Tuticorin Airport) 12 Supplying and Laying of HDPE pipe of 63mm OD of PE 80 PN 6 ISI marked along with all accessories like socket, bend,couplers etc. confirming to IS 4984,complete with fitting and cutting, jointing etc. direct in ground at a depth of 0.8m below the ground level i/c excavation and refilling the trench but excluding sand cushioining and protective etc as required. 13 Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. 14 Supply of following size of XLPE insulated PVC sheathed Aluminium conductor armoured power cable of 1.1 KV grade conforming to IS-7098 Part-I amended upto date etc. complete as required. 2 core x 25 sq.mm 15 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2Cx 25 sqmm 16 Excavation for cable trenches in soft soil, depth upto 1.2 m including dressing of sides lift upto 1.5 m, getting out the excavated soil, refilling with excavated soil after laying of cable/ pipe/ for site requirement etc. and disposal of surplus excavated soil as directed, within a lead of 50 meters, without ramming and watering etc as required. 17 Providing and laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size). 18 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of upto 1.1KV grade of following size in the existing RCC/ HUME/ METAL pipe/ Masonary Duct as required. 19 Supply of following size of XLPE insulated PVC sheathed copper conductor armoured power cable of 1.1 KV grade conforming to IS-7098 Part-I amended upto date etc. complete as required. 12Cx 1.5 sqmm
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 7
7.
Housing Urban and Rular Development #10408476 Price Bid
Tender For Need Base Maintenance Work Including Supply And Delivery Of Electrical Emergency Maintenance Materials For Asansol District Hospital, Asansol, Paschim Bardhaman.- 1 Distribution wiring in 2 x 22/0.3 (1.5 sqmm) single corestranded FR PVC insulated & unsheathed copper wire(Brand approved by EIC) in 20mm size PVC rigid conduit FR(Precision make), with 1x22/0.3 (1.5 sqmm) single corestranded FR PVC insulated & unsheathed copper wire forECC, to light/fan/call bell points with Piano Key type switchfixed on MS CRC sheet metal (16 SWG) switch board cumJB on wall complete with 2 no. suitable size “Ph & N” copperbar incl. bakelite/Perspex (wall matching color) top cover 3mm thick and incl. 175mmx100mmx65mm inspection box,making earthing attachment, painting the MS box andmending good the damages to original finishi)Average run 8 mtr 2 Distribution wiring in 1.1 KV single core stranded FRPVC insulated & unsheathed copper wire (Brandapproved by EIC) in 20mm size PVC rigid conduit FR(Precision make) incl. necy. fittings as requiredi) 2 x 22/0.3 (1.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC 3 ii) 2 x 36/0.3 (2.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC 4 iii)2 x 56/0.3 (4 sqmm) + 1 x 36/0.3 (2.5 sqmm) ECC 5 Supply & Delivery 1.1KV grade LT Aluminium PVC/XLPE Armoured cable( Make- Havells/ polycab/ RR/ KEI ) as per choice of EIC. The cable shall conform to IS 7098/ Part I with anti termite and anti rodent features.i) 4 Core 16 sq.mm. 6 ii) 4 core 25 sq.mm 7 Laying of cable upto 3/4 core 25 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip)Wire, making holes etc. as necy. mending good damages andpainting 8 Laying of one No. cable upto 35 sqmm in underground trench 460mm wide x 760 mm average depth, with brick protection on thetop of the cable with 8 (eight) Nos. bricks per metre, includingfilling the space between the brick & cable and also the trenchwith shifted soil, leveling up and restoring surface duly rammed. 9 Supplying and fixing compression type gland complete with brassgland, brass ring & rubber ring for dust & moisture-proof entry ofXLPE/PVC armoured cables as below :i) 4 Core 16 sq.mm. 10 ii) 4 core 25 sq.mm 11 Finishing the end of following XLPE/PVC armoured cables bycrimping method incl. supplying and fixing solderless socket(Dowels make), tapes, anticorrosive paste & jointing materials :i) 4 Core 16 sq.mm. 12 ii) 4 core 25 sq.mm 13 Supply & Fixing 240 V, 4 nos. 6A, plug socket with separate 4nos. 6 A Piano key type switch, indicator & 16A switch type SP MCB (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F 240x200x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required 14 Supply & Fixing 240 V, 20A, plug socket with separate 20 A Piano key type switch (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F 150x100x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required. 15 Supply & Delivery of 36W,4ft long(Philips Make) Flouroscent tube light only. 16 Supply& Delivery of 36/ 40 watt Electronic ballast for fluorescent tube light. [Phillips: EBE SLIM 1x36 TLD 240 or equivalent make of Crompton/Havells ] 17 Supply& Delivery of 36/ 40 watt Electronic ballast for fluorescent tube light. [Phillips: EBE SLIM 2x36 TLD 240or equivalent make of Crompton/Havells] 18 Supply & Delivery only Single commercial TLED tube retrofit metal batten frame.i).Single Tube batten[PHILIPS-TMC-501-P-1XT-LED-P3241/Crompton/Havells].(With 2 Years Warranty) 19 Supply & Delivery only Single commercial TLED tube lamp PCB Body having minimum 100Lumen/Watt.i).Single Tube [PHILIPS master LED or Equivalent make of Crompton/Havells]. (With 2 Years Warranty) 20 Supply & Delivery only Single commercial TLED tube Holder for fixing in Tube Batten. (ApprovedMake,as per choice of EIC) 21 Supply of 240V LED Lamps of Philips make of the following Wattage & Type. i) 9Watt LED B22/E14/E27 lamp. (ApprovedMake,as per choice of EIC). (With Minimum 1 Years Warranty). 22 Supply & Delivery 250v, 2.25 mfd burst proof(P-2type ) fan Capacitor(ApprovedMake,as per choice of EIC) 23 Supply & Delivery of 240V,Step Type Electronics Fan regulator. (ApprovedMake,as per choice of EIC) 24 Supply & Delivery of 240V flushed type Socket of the following ampere rating. (ApprovedMake,as per choice of EIC)i)6A; Multi Socket for 5 Pin 25 ii)16A , Socket 3Pin 26 Supply & Delivery of 240V piano key type Switch of the following ampere rating & Type. (ApprovedMake,as per choice of EIC)i)6A; 1Way. 27 ii)16A; 1Way 28 ii)Supply & Delivery of 240V Moduler type Socket of the following ampere rating. (Anchor/Legrand or as per direction of EIC)16A , Socket 3Pin. 29 ii)Supply & Delivery of 240V Moduler type Switch of the following ampere rating & Type. (ApprovedMake,as per choice of EIC) 16A; 1Way. 30 Supply & Delivery of 20ASwitch Socket(SS) combination with Shutter & 4 fixing holes. (ApprovedMake,as per choice of EIC) 31 Supply & Delivery of 240 V ,20A single phase DOL Starter. (ApprovedMake,as per choice of EIC) 32 Supply & Delivery of 240 V ,21A single phase OLP3+ Starter(ApprovedMake,as per choice of EIC) 33 Supply & Delivery of Angle Holder for fixing Lamp.(ApprovedMake,as per choice of EIC) 34 Supplying and fixing 415V, TPN SFU with sheet steel enclosure on flat iron/angle iron frame on wall with nuts bolts etc incl. S & F 3 nos. DIN type HRC fuse as per rating.(Make-L&T/Siemens/Havells) 63A on flat iron frame. 35 100A on flat iron frame. 36 125A on flat iron frame. 37 Supplying & fixing sheet metal 415 V, 100/125 A(16 SWG) Iron Clad 4 bar copperBusbar chambers on angle iron frame on wall, incl. earthing attachment and painting as required – (As per Drawing no. 470 of PWD SpecificationBook – May 1991)Dimension ofCu. bars4 x 15x3mm[85mm long],Dimension of Sheet MetalBox-500x150mm. 38 Supplying and delivery of 250 volts, 50Hz,(12”) sweep 1420 R.P.M. heavy duty exhaust fan complete with all accessories after making hole on wall and mending good damages as per practicable incl. providing necessary CU wire for connection & S and F louver shutter ((ApprovedMake,as per choice of EIC)) as to Gs. i) Exhaust fan(12”) 39 Supplying and delivery of 250 volts, 50Hz,(9”) sweep 1420 R.P.M. heavy duty exhaust fan complete with all accessories after making hole on wall and mending good damages as per practicable incl. providing necessary CU wire for connection & S and F louver shutter (ApprovedMake,as per choice of EIC) as to Gs. ii)Exhaust fan(9”) (With 2 Years Warranty) 40 Supply of 48ceiling fanscomplete with all accessories like fan blade,canopy,capacitor etc Model / Cat No.( Make - USHA /Crompton Greaves/Havells ) as per direction of EICa.1200 mmSweep (With 2 Years Warranty) 41 Supply and delivery of 240V, 70W LED street light having IP-66 protection ,efficacy-minimum 120Lumen/watt,10KV SPD included.(Make-crompton model no-TRP-421-70-57-SL-LM-NBK or eqivalant make of Philips/Havells)(With 2 Years Warranty) 42 Supply and delivery of 240V, 150W LED street light having IP-66 protection,efficacy-minimum 110/120Lumen/watt,10KV SPD included.(Make-crompton model no-TRP-424-150-57-HL2-LM-NSG or eqivalant make of Philips/Havells)(With 2 Years Warranty) 43 Add GST @18% On total from item no 1 to 33. 44 Add LWC @1% On total from item no 1 to 34.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
West Bengal View Result →
8.
Public Administrative Department #10379186 Price Bid
Supply, Installation, Testing, Commissioning And Maintenance For Cctv Camera Surveillance System And Integrated Command Control ( Iccc ) Surveillance System For Palghar Muncipal Conucil Area 58 Cameras And 3 Year Amc ( Semi-Comprehensive Service And M , Supply, Installation, Testing, Commissioning And Maintenance For Cctv Camera Surveillance System Andintegrated Command Control ( Iccc ) Surveillance System For Palghar Muncipal Conucil Area 58 Cameras And 3 Year Amc ( Semi-Comprehensive Service And Maintenance Contract 3 Years ) . Palghar. , Supply, Installation, Testing & Commisioning Of 5Mp Bullet Camera Image Sensor 1 / 2.9 Progressive Scan Cmos Min. Illumination Color: 0.01 Lux @ ( F1.2, Agc On ) , 0.028 Lux @ ( F2.0, Agc On ) , 0 Lux With Ir Shutter Speed 1 / 3 S To 1 / 100, 000 S Slow Shutter Yes Day & Night Ir Cut Filter Digital Noise Reduction 3D Dnr Wdr 120Db 3-Axis Adjustment Pan: 0° To 360°, Tilt: 0° To 100°, Rotate: 0° To 360° Focal Length 2.8 / 4 / 6 / 8 Mm Aperture F2.0 Focus Fixed Fov 2.8 Mm, Horizontal Fov: 97°, Vertical Fov: 63°, Diagonal Fov: 120° 4 Mm, Horizontal Fov: 78°, Vertical Fov: 50°, Diagonal Fov: 97° 6 Mm, Horizontal Fov: 60°, Vertical Fov: 39°, Diag Onal Fov: 75° 8 Mm, Horizo Ntal Fov: 39.5°, Vertical Fov: 26°, Diagon Al Fov: 48° Lens Mount M12 Ir Range Min 50 M Wavelength 850Nm Video Compression Main Stream: H.265 / H.264 Sub-Stream: H.265 / H. 264 / Mjpeg Third Stream: H.265 / H.264 H.264 Type Main Profile / High Profile H.264+ Main Stream Supports H.265 Type Main Profile H.265+ Main Stream Supports Video Bit Rate 32 Kbps To 16 Mbps. Smart Event Line Crossing Detection, Intrusion Detection, Face Detection Basic Event Motion Detection, Video Tampering Alarm, Exception ( Network Disconnected, Ip Address Conflict, Illegal Login, Hdd Full, Hdd Error ) Linkage Method Trigger Recording: Memory Card, Network Storage, Pre-Record And Post-Record Trigger Captured Pictures Uploading: Ftp, Http, Nas, Email Trigger Notification: Http, Isapi, Email Region Of Interest Support 1 Fixed Region For Main Stream And Sub-Stream Max. Resolution, 25 Fps In All Resolution 30Fps ( 2560 × 1440, 1920 × 1080, 1280 ×720 ) Sub-Stream 50Hz: 25Fps ( 640 × 480, 640 × 360, 320 × 240 ) 60Hz: 30Fps ( 640 × 480, 640 × 360, 320 × 240 ) Third Stream 50Hz: 25Fps ( 1280 × 720, 640 × 360, 352 × 288 ) 60Hz: 30Fps ( 1280 × 720, 640 × 360, 352 × 240 ) Image Enhancement Blc / 3D Dnr / Hlc Image Setting Rotate Mode, Saturation, Brightness, Contrast, Sharpness, Agc, And White Balance Are Adjustable Byclient Software Or Web Browser Target Cropping No Day / Night Switch Day / Night / Auto / Schedule Network Storage Support Micro Sd / Sdhc / Sdxc Card ( 128G ) , Local Storage And Nas ( Nfs, Smb / Cifs ) , Anr Protocols Tcp / Ip, Udp, Icmp, Http, Https, Ftp, Dhcp, Dns, Ddns, Rtp, Rtsp, Rtcp, Pppoe, Ntp, Upnp, Smtp, Snmp, Igmp, 802.1X, Qos, Ipv6, Udp, Ssl / Tls General Function Anti-Flicker, Three Streams, Heartbeat, Mirror, Privacy Masks, Password Reset Via E-Mail, Pixel Counter, Http Listening Security Password Protection, Complicated Password, Https Encryption, 802.1X Authentication ( Eap-Tls 1.2, Eap-Leap, Eap-Md5 ) , Watermark, Ip Address Filter, Basic And Digest Authentication For Http / Https, Wsse And Digest Authentication For Onvif, Tls1.2Api Onvif ( Profile S, Profile G, Profile T ) , Isapi, Sdk Simultaneous Live View Up To 6 Channels User / Host Up To 32 Users 3 Levels: Video Output No Communication Interface 1 Rj45 10M / 100M Self-Adaptive Ethernet Port On-Board Storage Built-In Microsd / Sdhc / Sdxc Slot, Up To 128 Gb Svc H.264 And H.265 Encoding Support Reset Button Yes Operating Conditions -30 °C To +60 °C ( -22 °F To +140 °F ) , Humidity 95% Or Less ( Non-Condensing ) Power Supply 12 Vdc ± 25%, F 5.5Mm Coaxial Power Plug Poe ( 802.3Af, Class 3 ) Power Consumption And Current :12 Vdc, 0.6 A, Max. 7 W Poe: ( 802.3Af, 36 V To 57 V ) , 0.3 A To 0.2 A, Max. 8.5 W Max. 12 W Protection Level Ip67. Warranty Of 1 Year. , Supply, Installation, Testing & Commisioning.Of 5Mp Bullet Camera. Image Sensor-1 / 2.7 Cmos, Max. Resolution-2592 ( H ) × 1944 ( V ) , Rom-128 Mb, Ram-512 Mb, Scanning System Progressive Electronic Shutter Speed Auto / Manual 1 / 3 S–1 / 100, 000 S Min. Illumination 0.005 [email protected] ( Color, 30 Ire ) 0.0005 [email protected] ( B / W, 30 Ire ) 0 Lux ( Illuminator On ) S / N Ratio>56 Db Illumination Distance-60 M ( 196.85 Ft ) ( Ir Led ) Illuminator On / Off Control Auto;Manual Illuminator Number 4 ( Ir Led ) , Pan / Tilt / Rotation Range Pan: 0°–360° Tilt: 0°–75° Rotation: 0°–360° Lens Type Motorized Vari-Focal Lens Mount F14 Focal Length-2.7 Mm–13.5 Mm, Max. Aperture-F1.5 Field Of View H: 100°–30° V: 72° –23° D: 134° –38° Iris Control-Fixed Close Focus Dista Nce-0.8 M ( 2.62 Ft ) Dori Distance Lens Detect Observe Recognize Identify W 64.4 M ( 211.29 Ft ) 25.8 M ( 84.65 Ft ) 12.9 M ( 42.32 Ft ) 6.4 M ( 21.00 Ft ) T221.4 M ( 726.37 Ft ) 88.6 M ( 290.68 Ft ) 44.3 M ( 145.34 Ft ) 22.1 M ( 72.51 Ft ) Ivs ( Perimeter Protection ) Tripwire; Intrusion ( The Two Functions Support The Classification And Accurate Detection Of Vehicle And Human ) Smart Search-Work Together With Smart Nvr To Perform Refine Intelligent Search, Event Extraction And Merging To Event Videos.Video Compression 25 Fps In All Resolution Bit Rate Control Cbr / Vbr Video Bit Rate H.264: 3 Kbps–8192 Kbps H.265: 3Kbps–8192 Kbps Day / Night Auto ( Icr ) / Color / B / W Blc Yes Hlc Yes Wdr 120 Db Scene Self-Adaptation ( Ssa ) Yes White Balance Auto; Natural; Street L Outdoor; Manual; Regional Custom Gain Control Auto;Manual Noise Reduction 3D Dnr Motion Detection Off / On ( 4 Areas, Rectangular ) Region Of Interest ( Roi ) Yes ( 4 Areas ) Smart Illumination Yes Image Rotation 0° / 90° / 180° / 270° ( Support 90° / 270° With 1080P Resolution And Lower ) Mirror Yes Privacy Masking 4 Areas. Audio Compression G.711A; G.711Mu; Pcm; G.726 ( Only - Zas Supports ) . Alarm Event -Zas:No Sd Card; Sd Card Full; Sd Card Error; Network Disconnection; Ip Conflict; Illegal Access; Motion Detection; Video Tampering; Intrusion; Tripwire; Scene Changing; Audio Detection; Voltage Detection; Defocus Detection; External Alarm; Smd; Safety Exception-Zs:No Sd Card; Sd Card Full; Sd Card Error; Network Disconnection; Ip Conflict; Illegal Access; Motion Detection; Video Tampering; Intrusion; Tripwire; Scene Changing; Voltage Detection; Defocus Detection; Smd; Safety Exception. Network Port Rj-45 ( 10 / 100 Base-T ) Sdk And Api Yes Cyber Security Video Encryption; Firmware Encryption; Configuration Encry Ption; Digest; Wsse; Account Lockout; Security Logs; Ip / Mac Filtering; Generation And Importing Of X.509 Certific Ation; Syslog; Https; 802.1X; Trusted Boot; Trusted Exec Ution; Trusted Upgrade Network Protocol Ipv4; Ipv6; Http; Tcp; Udp; Arp; Rtp; Rtsp; Rtcp; Rtmp; Smtp; Ftp; Sftp; Dhcp; Dns; Ddns; Qos; Upnp; Ntp; Multicast; Icmp; Igmp; Nfs; Samba; Pppoe; Snmp Interoperability Onvif ( Profile S / Profile G / Profile T ) ; Cgi; P2p; Milestone; Genetec User / Host 20 ( Total Bandwidth: 64 M ) Storage Ftp; Sftp; Micro Sd Card ( Support Max. 256 Gb ) ; Nas Browser Ie Chrome, Firefox Management Software Smart Pss; Dss; Dmss Mobile Client-Ios; Android.Audio Input 1 Channel ( Rca Port ) ( Only - Zas Supports ) Audio Output 1 Channel ( Rca Port ) ( Only - Zas Supports ) Alarm Input 1 Channel In: 5 Ma 3–5 Vdc ( Only - Zas Supports ) Alarm Output 1 Channel Out: 300 Ma 12 Vdc ( Only - Zas Supports ) Power Supply 12 Vdc / Poe ( 802.3Af ) Power Consumption Basic: 3.3 W ( 12 Vdc ) ; 4.2 W ( Poe ) Max ( Wdr + Ir Intensity + Intelligence On ) : 7.8 W ( 12 Vdc ) ; 9.7 W ( Poe ) Environment Operating Temperature –30 °C To +60 °C ( –22 °F To +140 °F ) Operating Humidity =95% Storage Temperature–40 °C To +60 °C ( –40 °F To +140 °F ) Protection Ip67.Warranty Of 1 Year. , Supply & Installation Of Camera Housing For Outdoor Suitable For High Temperature Environment, Working Temperature- 20? ~ +60?, Humidity 95% Or Less ( Non-Condensing ) , Main: Aluminum Alloy Window: Glass, Dimension ( Mm ) -455.3×169.2×110, Protection Level-Ip67. , Supply & Installation Of Camera Bracket Mount With Bracket Type: Pan Tilt Brackets, Dimensions Mm: 190 X 200 X 500 Mm, Max Load Kg-50, Housing Material-Steel. , Supply, Installation, Testing & Commisioning. 4 X 100M Poe Ports, 1 X 1000M Rj45 Port, And 1 X 1000M Sfp Fiber Optical Port. Supports Ieee 802.3At / Af. Supports Ieee 802.3, Ieee 802.3U And Ieee 802.3X.Supports High Priority Ports. Supports 8-Core Power Supply. Up To 250 M Transmission Distance. Poe Port With 6 Kv Surge Protection.Supports Poe Output Power Management. 1000M Network Access.Wire-Speed Forwarding And Non-Blocking Design.Store-And-Forward Switching.Solid High-Strength Metal Shell.Power Supply Specification 100~240 Vac, 50 / 60 Hz, Max. 2.5 A. Warranty Of 1 Year. , Supplying And Laying Of Cat-6 Cable With Rodent Proof And Anti Termite Jacket Suitable For Networking As Per Specification No. Wg-Coc / Nc , Supplying And Laying Of Cat-6 Armoured Cable With Eccs Tape Suitable For Networking As Per Specification No. Wg-Coc / Nc , Supply, Installation, Testing & Commisioning. 128G 128Gb Microsd Cards For Surveillance 128 Gb Maximum Read Speed: 96 Mb / S Maximum Read Speed: 96 Mb / S Compatible With Microsdhc, Microsdxc, Microsdhc Uhs-I, And Microsdxc Uhs-I Host Devices. Warranty Of 1 Year. , Supply, Installation & Testing Of 6 U Outdoor Rack Item Type Technical Parameter Layout & Mounting One Compartment, Pole & Wall Mountable Equipment Installation Method 19” Standard Rack Door With One Front Door With Lock ( Support Padlock ) Material 1.Galvanized Steel;2.Single Wall, Thickness Of : 1.2Mm, Thickness Of Mounting Angles:1.5Mm Structure Assembled, Welded Constructions, Ingress Protection Ip65 Temperature Control Cooling Ac220v 90 Cfm Dual Fan.Lighting Led Lamp Ac230 V Or Dc 48V Led Lamp- Optional Temperature Temperature Working Temperature: -40°C ~ +55°C Storage Temperature: -50°C ~ + 70°C Transport Temperature: -50°C ~ +70°C Humidity Relative Humidity 5% ~ 100% Pressure Air Pressure 62Kpa ~ 101Kpa ( Similar To 0M ~ 5000M Altitude ) Radiation Intensity Solar Radiation Intensity 1124 × ( 1±5% ) W / M2 ) Warranty For 1 Year. , Supply, Installation, Testing & Commisioning. Media Converter, Auto-Negotiation Of Half-Duplex / Full-Duplex Transfer Mode Extends Fiber Distance Up To 15Km.1× 1000M Sc / Upc Port 1× 10 / 100 / 1000M Rj45 Port ( Auto Mdi / Mdix ) . Single-Mode Fiber, Utp Category 5, 5E Cable ( Maximum 100M ) Eia / Tia-568 100O Stp ( Maximum 100M ) .Operating Temperature: 0?~50? ( 32?~122? ) . Warranty Of 1 Year. , Supplying And Erecting Lszh Armoured Multimode Optical Fibre Cable With 12 Fibres, Core Dia 50 / 125 ?M ( Om3 ) , Suitable Up To 10 Gbps Ethernet Distance At 850 Nm Of Wavelength, On Wall / Ceiling Or Laid In Provided Pipe / Trench As Per Specification No. Wg-Coc / Ofc , Providing & Erecting 5 M High ( Clear Height ) Galvanised Octagonal Pole With Foundation Bolts Having Bottom Of 130 Mm A / F, Top 70 Mm A / F On Provided Foundation As Per Specification No. Oh-Pl / Opl. , Making M- 20 Grade Reinforced Cement Concrete Foundation By Considering The Safe Soil Bearing Capacity As 10 T / Sq.M At 1.5 M Depth Including Supply Of Steel, Concrete, Excavation, Fixing Provided Nut Bolts With The Help Of Template, Duly Plastered As Per Design Complete ( For 3 To 5M Octagonal / Conical Gi Pole ) . , Supply, Lnstallation, Testing & Commissioning Of Nvr Viewer Workstation ( Hp / Dell / Lenovo ) With Duel Monitor Support , With Nvr Viewer Software And License Operating System 12Th Gen Lntel Corerm I5- Processor Windows 10 Pro ( Windows 1 1 Pro License Included ) , English8 Gb, Ddr5, 256 Gb, M.22230, Pcle Nvme, Ssd, Class 35 Power Button; Hard Disk Drive Activity Light ;. Line Ln / Out 4. Universal Audio Jack S.Usb 3.2 Gen 2Type A With Power Share 6. Usb 3.2 Gen2x2 Type C ( 20Gb Data ) Back ( 35W ) : Knock-Out Slot For External Wireless Antenna ( Optional ) ; Optional Video Port ( Hdmi 2.0B1 Displayport 1.4A1 Vga / Usb Type-C With Displayport Alt Mode ) ; Usb 3.2 Type A Ports ( 2 - One With Power On ) ; Padlock Ring And Kensington Security Cable Slot ; Ethernet Rj-45 12. Usb 3.2 Gen 2 Type A Ports ( 2 ) ; Display Ports 1.A ( 1 ; Power Adapter Portback ( 65W ) : ; Knock-Out Slot For Wireless Antenna ; Optional Video Port ( Hdmi 2.0Bl Displayport 1.4A1 Vga / Usb Type-C With Displayport Alt Mode ) ; Usb 3.2 Gen 1 Type A With Smart Power On; Padlock Ring And Kensington Security-Cable Slot ; Ethernet Rj-45; Usb 3.2 Gen 2 Type A Ports ( Z ) ; Displayport 1.4 Ports ( 3 ) ; Power Adapter Port.Warranty Of 1 Year. , Supplying, Erecting, Testing And Commissioning Of 3Kva Capacity Online Pure Sine Wave With Backup Time Of ....... Hrs. Pwm & Igbt Based Ups With 0.8 To Unity Output Pf, Single Phase Input & 1 Phase Output Complete With All Protections As Per Specification No. Ap-Ups. Warranty Of 1 Year. , Supplying And Erecting 12 V / 65Ah Smf Battery With Battery Terminal Wire, Duly Charged Complete With 24 Months Warranty Complete. Warranty Of 1 Year. , Supply, Installation Testing And Commissioning Of Router - Cable Or Dsl Modem With Ethernet Port, 4 10 / 100 Lan Ports, 1 10 / 100 Wan Port, 2.4 Ghz To 2.497 Ghz, Wep 64 / 128-Bit Data Encryption, Wi-Fi Protected Access ( Wpa / Wpa2 ) , Wps, Network Address Translation ( Nat ) , Stateful Packet Inspection ( Spi ) , Mac Address Filtering, Url Filtering, Power, Internet Status, Wlan , Lan.Warranty Of 1 Year. , Supply, Installation, Testing & Commisioning. Uhd 4K Led Display 86 Interactive Panel With Resolution Of 3840 × 2160 ? Anti-Glare And Anti-Blocking Design To Ensure Smooth Interaction? Dual Systems Of Windows And Android Saving Cost And Easy To Use? Quick Response, At Most 20-Point Touch Control And Smooth Writing Experience? Dual Usb 3.0 Interfaces, And Data From Any Interface Can Be Read In Windows And Android System At The Same Time? Enable The Floating Ball By Gesture To Realize Writing, Erasing, Screenshoting And Freezing In Any Channel? Mirroring By Mobile Phone Or Tablet To Realize Remote Control And Flexible Teaching? Teaching Software Integrating Kinds Of Tools And Materials, Convenient Writing, Erasing, Recording, Preparing And Teaching ? Scan The Qr Code To Save The Teaching Notes ? All-In-One Design With Tempered Glass And Intelligent Temperature Control, Making It Environmental-Friendly And Safety-Guaranteed.Warranty Of 1 Year. , Supply Installation & Testing Ofvms, An Integrated Security Software, Is Designed To Meet Versatile Security Challenges In One Intuitive Platform: From Managing Individual Systems Such As Video Security, Access Control, Intrusion Alarm, Etc., To Collaborating Multiple Systems Under A Unified Architecture. While Protecting People And Property, It Makes Daily Operations More Efficient, And Helps Various Kinds Of Users Make Smarter Decisions. , Supply, Installation And Testing Of 10 Tb Surveillance Storage Hard Disk Drive -24R Surveillance Hdo Capacity - 8 Tb Interface Sata Iii 6 Gb / S Max Sustained Transfer Rate Od-210 Mbs Cache - 256 Mb Tamish Resistant Load / Unloadcycles-300 000 Power On Hours / Year 8760 Mean Tim Between Failures ( Mtbf ) - 1 Million Hours Operating Temperature - Ambient : 41 F / 5 C ( Min ) Drive Case : 158 F / 70 C ( Max ) Non Operating Temperature Ambient : 40 F / 10C ( Min ) . Warranty Of 1 Year. , Supply, Installation Testing And Commissioning Of 21 U Rack Rack Standard : Conforms To Din 41494 Or Equivalent Standardconstruction : Welded Or Ckd ( Knockdown ) Front Door : Lockable Double Toughened Glass Door Or Perforated Basic Frame : Steel Equipment Mounting : Din Standard 10Mm Sq. Slots / Direct M6 Tapmounting Angle : 19” Mounting Angles Made Of Formed Steelstandard Finish : Powder Coatedtop And Bottom Cover : Welded To Frame, Vented And Cable Entry / Exit Cut Outs From Top & Bottom Standard Mounting Option : Castor Wheels ( Front 2 Wheels With Break And Rear Without Break ) Or Levelers Standard Color : Grey Or Black Static Load : 500Kgs. Warranty Of 1 Year. , Supply, Installation Testing And Commissioning Of 8 Port Poe Later 2 Indoor Network Switches With 2 Sfp Port And Modules Complete As Required. 3 Years Defect Liability Period, All Necessary Maintenance, Transportation, Rack And Taxes.Warranty Of 1 Year. , Supply, Installation Testing And Commissioning Of Nvr For Video And Audio Ip Video Input 64-Ch Up To 12 Mp Resolution*: 32 Mp And 24 Mp Is Only Available For Channel 1 When Ultra Hd Resolution Mode Is Enabled. Incoming Bandwidth 320 Mbps Outgoing Bandwidth 256 Mbps Incoming Bandwidth ( Raid Mode ) 200 Mbps Outgoing Bandwidth ( Raid Mode ) 200 Mbps Hdmi 1 Output 4K ( 3840 × 2160 ) / 60Hz, 4K ( 3840 × 2160 ) / 30Hz, 1920 × 1080 / 60Hz, 1600 × 1200 / 60Hz, 1280 × 1024 / 60Hz, 1280 × 720 / 60Hz, 1024 × 768 / 60Hz Hdmi 2 Output 1920 × 1080 / 60Hz, 1280 × 1024 / 60Hz, 1280 × 720 / 60Hz, 1024 × 768 / 60Hzvga 1 Output 1920 × 1080 / 60Hz, 1280 × 1024 / 60Hz, 1280 × 720 / 60Hz, 1024 × 768 / 60Hz Vga 2 Output1920 × 1080 / 60Hz, 1280 × 1024 / 60Hz, 1280 × 720 / 60Hz, 1024 × 768 / 60Hz Video Output Mode Hdmi 1 And Vga 1 Provide Simultaneous Video Output, And Work As The Main Output;Hdmi 2 And Vga 2 Provide Simulta Neous Video Output, And Work As The Auxiliary Output Cvbs Output 1-Ch, Bnc ( 1.0 Vp-P, 75 O ) , Resolution: Pal: 704 × 576, Ntsc: 704 × 480 Audio Output2-Ch, Rca ( Linear, 1 K? ) Two-Way Audio1-Ch, Rca ( 2.0 Vp-P, 1 K?, Using The Audio Input ) Decoding Decoding Format H.265+ / H.265 / H.264+ / H.264 / Mpeg4 Recording Resolution 32 Mp / 24 Mp / 12 Mp / 8 Mp / 6 Mp / 5 Mp / 4 Mp / 3 P / 1080P / Uxga / 720P / Vga / 4Cif / Dcif / 2Cif / Cif / Qcif *: 32 Mp And 24 Mp Is Only Available For Channel 1 When Ultra Hd Resolution Mode Is Enabled. Synchronous Playback 16-Ch Decoding Capability 1-Ch@32 Mp ( 30 Fps ) / 2-Ch@12 Mp ( 20Fps ) / 4-Ch@8 Mp ( 25Fps ) / 8-Ch@4 Mp ( 30Fps ) / 16-Ch@1080P ( 30Fps ) Dual-Stream Recording Support Stream Type Video, Video & Audio Audio Compression. 711Ulaw / G.711Alaw / G.722 / G. 726 / Aac / Mp2l2 / Pcm Network Remote Connection 128 Network Protocoltcp / Ip, Dhcp, Ipv4, Ipv6, Dns, Ddns, Ntp, Rtsp, Sadp, Smtp, Snmp, Nfs, Iscsi, Isup, Upnp™, Http, Https Network Interface 2, Rj-45 10 / 100 / 1000 Mbps Self-Adaptive Ethernet Interface Raid Raid Type Raid0, Raid1, Raid5, Raid6, And Raid10 ( At Least 4 Tb For Each Hdd ) Auxiliary Interface Serial Interface 1 Rs-485 ( Full-Duplex ) , 1 Rs-232, 1 Keyboard, 10 Sata Interfaces Supporting Hot-Plug Esata 1 Esata Interface Capacity-Up To 10Tb Capacity For Each Disk. Alarm In / Out-16 / 4. Usb Interface Front Panel: 2 × Usb 2.0; Rear Panel: 1 × Usb 3.0 Power Supply-100 To 240 Vac, 50 To 60 Hz Consumption-30 W Working Temperature-10 °C To 55 °C ( 14 °F To 131 °F ) Working Humidity 10% To 90% Chassis 3U Weight-10 Kg ( 22 Lb ) .Warranty Of 1 Year. , Supplying, Installing And Testing Utp Connector ( Rj-45 ) As Per Specification No.Wg-Nas / Utpc. , Amc ( Semi-Comprehensive ) Forcamera Complete Solution From On Field Equipments To Command Control Setup For 2Nd Year Where Upto Rs.1000 Will Be Waived Off Or Bare By Agency.From Agency Twice Inspection Will Be Done In A Month And Camera Position And Working Status Of Camera Will Be Updated. ( Parts Includes In Semi Comprehensive Amc Are Camera, Poe Switch, Tv, Work Station, Memory Card, Nvr, Inverter & Batteries ) . , Amc ( Semi-Comprehensive ) Forcamera Complete Solution From On Field Equipments To Command Control Setup For 3Rd Year Where Upto Rs.1000 Will Be Waived Off Or Bare By Agency.From Agency Twice Inspection Will Be Done In A Month And Camera Positionand Working Status Of Camera Will Be Updated. ( Parts Includes In Semi Comprehensive Amc Are Camera, Poe Switch, Tv, Work Station, Memory Card, Nvr, Inverter & Batteries ) . , Amc ( Semi-Comprehensive ) Forcamera Complete Solution From On Field Equipments To Command Control Setup For 4Th Year Where Upto Rs.1000 Will Be Waived Off Or Bare By Agency. From Agency Twice Inspection Will Be Done In A Month And Camera Position And Working Status Of Camera Will Be Updated. ( Parts Includes In Semi Comprehensive Amc Are Camera, Poe Switch, Tv, Work Station, Memory Card, Nvr, Inverter & Batteries ) . , Add 4% Contigency Rs.
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 5
Maharashtra View Result →
9.
Civil Aviation #10292355 Price Bid
Tender For Miscellaneous Electrical Works At Datia Airport.; 1 Design, Supply, Installation, Testing and Commissioning of FAA compliant, indoor type Micro- processor based Constant Current Regulator(CCR) suitable for remote as well as local control operations with 5 position brightness control (6.6A maximum current corresponding to 100% brightness) on input voltage 230/415 V, 50 Hz., AC supply, provision for control supply with all switchgears, CCR protections, connection/ inter-connections etc. and confirming to tenders technical specifications complete as required.a) 4 KW, 6. 6A output current. 2 Supply of single core x 6 sq. mm sizes 5 KV grade PVC insulated & PVC sheathed, antitermite & anti- rodent,multi-strandedcopperconductorsinglecoreairfieldlightingcableconfirmingtoIS 1554 (Part II) with up to date amendments complete as required. 3 Supply of 4 core x 25 Sqmm. XLPE insulated PVC sheathed armoured aluminium conductor cable of 1.1 KV Grade confirming to IS:7098 (Part 1) with upto date amendment etc. complete as required. 4 Supply of 3 core x 16 Sqmm. XLPE insulated PVC sheathed armoured aluminium conductor cable of 1.1 KV Grade confirming to IS:7098 (Part 1) with upto date amendment etc. complete as required. 5 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.63 mm dia (OD-63 mm & ID-51 mm nominal) 6 Laying of one number PVC insulated and PVC sheathed/ XLPE power cable of 5 KV grade of 6 sqmm size in the existing RCC/GV/ DWC HUME/ METAL pipe etc. as required. 7 Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required. 8 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Up to 35 sqmm 9 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.Up to 35 sqmm 10 Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Up to 35 sqmm 11 Supply of 5 KV grade plug and receptacle ,suitable for field attachment with 5 KV grade PVC insulated, PVC sheathed single core 6 sq. mm copper conductor AGL cable complete etc. as required. 12 Making connections of 5 KV grade, 6 Sq. mm Copper conductor AFL cables withplug and receptacle connector i/c crimping & fixing, applying HT tape complete as required. 13 SITC of Mini Remote Control Desk havingprovision for control of PAPI both side landing T and windsock and 1 CCR spare i/c MIMIC display etc. complete as required. 14 Supply and fixing of 24 core X 1.5 Sq. mm Copper conductor armoured 1.1 KV grade XLPE insulated PVC Sheathed control cable as per IS 7098 Part-1 1988 as amended upto date as per site requirement. 15 Supply, Erection and termination CRCA sheet 3mm powder coated control cable end termination junction box to be mounted on wall 300mm X 200 mm X 500mm 16 Earthing with G. I. pipe 4.5 m long x 40 mm dia. (Drilling of 300 mm dia, 4.5 Mtr deep by using Borewell machine) including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. includingcharcoal or coke and salt complete as required. 17 Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. 18 Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections complete etc. as required. 19 Supplying and fixing following DB- Phase Segregated DB 12 Way Double Door 8 Incomer 4+4+4 Sub Incomer 12+12+12 Outgoing, of steel sheet for 415 volts on surface/ recess complete with loose wire box, terminal connectors for all incoming and outgoing circuits, duly prewired with suitable size FR PVC insulated copper conductor up to terminal blocks, tinned copper bus bar, neutral link, earth bar, din bar, detachable gland plate, interconnections, powder painted, IP54 including earthing etc. as required.(But without MCB/ RCCB/ Isolator) 20 Supplying and fixing distribution board of 12way double door SP, steel sheet for 230 volts on surface/ recess complete with loose wire box, terminal connectors for all incoming and outgoing circuits, duly prewired with suitable size FR PVC insulated copper conductor up to terminal blocks, including earthing etc. as required.(But without MCB/ RCCB/ Isolator) 21 Supplying and fixing 63 amps rating, 240/415 volts, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 A TPN MCB 22 Supplying and fixing 32 amps rating, 240/415 volts, C curve, Double Pole miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 23 Supplying and fixing following rating, two pole,230 volts, residual current circuit breaker (RCCB), having a sensitivity current30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 A 24 Supplying and fixing 6 amps rating, 240volts,10kA, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole 25 Supplying and fixing 16 amps rating, 240volts,10kA, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole 26 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C 27 Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. 28 Wiring for circuit/ sub main wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire 29 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 1 no. 5 pin 5/6 A & 1 no. twin 6/16 A modular socket outlet and 1 no. 5/6 A & 1 no. 15/16 A modular switch, connections etc. as required. 30 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 2 no. 5 pin 5/6 Amodular socket outlet and 2 no. 5/6 Amodular switch, connections etc. as required. 31 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 1 no. twin 6/16 A modular socket outlet and 1 no. 15/16 A modular switch, connections etc. as required. 32 Supply of energy efficient 5 star rated BLDC ceiling fan, 1200 mm sweep remote operated suitable for operation on 240V, 50Hz A.C. supply with down rod canopies etc. complete as required. (Maximum power consumption - 28W) 33 Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required. 34 Supply of energy efficient wall fan Hiflo Wave Plus 60W KD White Wall Fan Sweep: 400 mm suitable for operation on 240V, 50Hz A.C, complete as required. (Maximum power consumption - 60W) 35 Installation, testing and commissioning of wall mount fan, including wiring with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. complete as required. 36 Supply of 230 mm sweep metallic exhaust fan suitable for operation on 240V, 50Hz A.C. supply, 1400 rpm with all accessories including louvers, shutters etc. complete as required. 37 Installation of exhaust fan of size 230 mm sweep in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. 38 Supply of minimum 15 Watt recessed mounting LED downlight with minimum output 1500 lumens suitable for 140-270 V, AC, 50 HZ, PF>0.95, luminaire should have extruded aluminium / CRCA / Extended alloy housing. Luminaire should have proper thermal management, Min IP protection should be IP 20. Total power consumption of fitting (including driver loss) should not more than 110 % of rated capacity of LED Light fitting, complete with all accessories as required. 39 Supply of minimum 30 W LED recessed 2ft X 2ft luminaire with minimum output 3000 lumens suitable for 140-270 V, AC, 50 HZ, PF>0.95, luminaire should have extruded aluminium / CRCA / Extended alloy housing. Luminaire should have proper thermal management, Min IP protection should be IP 20. Total power consumption of fitting (including driver loss) should not more than 110 % of rated capacity of LED Light fitting, complete with all accessories as required. 40 Supply of minimun 40 W LED street light fitting with minimum output of 4400 lumens suitable for 140-270 V, AC, 50 HZ, PF>0.95, luminaire should have High pressure die cast Aluminium /Standard alloy housing. Luminaire should have Air vents in housing for proper thermal management, Min IP protection should be IP 65. Total power consumption of fitting (including driver loss) should not more than 110 % of rated capacity of LED Light fitting, complete with all accessories as required. 41 Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent / LED Fittings of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. 42 Supply, Installation, Testing & Commissioning of 2 Ton (5 Star) Inverter Split Air conditioning unit fittedwith rotary compressor alongwith indoor/outdoor units, gas R-410A or eco-friendly gassuitable to operate on 230V +/- 10%, 50 Hz, single phase AC power supply capable of performing the function as Dehumidification, air circulating and filtering complete with compressor, evaporators, air cooled copper condenser connected refrigerant piping (upto 10 feet) electrical wiring including MS stand suitable for outdoor unit with all accessories complete etc as required. 43 Supply, Installation, Testing & Commissioning of 1.5 Ton (5 Star) Inverter Split Air conditioning unit fittedwith rotary compressor alongwith indoor/outdoor units, gas R-410A or eco-friendly gassuitable to operate on 230V +/- 10%, 50 Hz, single phase AC power supply capable of performing the function as Dehumidification, air circulating and filtering complete with compressor, evaporators, air cooled copper condenserconnected refrigerant piping (upto 10 feet) electrical wiring including MS stand suitable for outdoor unit with all accessories complete etc as required. 44 SITC of Floor Standing RO Purifier Chiller & Dispenser having RO + UF + TDS Control with minimum Flow Rate 30L/hr and storage 20L Tank complete as required 45 SITC of 1.5kVA stand-alone solar power system having 3no. 530Wp monocrystalline solar panel,1no. 24V 1.5kVA solar inverter with MPPT feature, 2no. 150Ah solar tubular batteries, complete with DCDB box, earthing, Lightning arrestor installation and module mounting structure and associated all cabling complete etc. as required.Preferred make-TATA POWER or equivalent. 46 Supply of 3 core x 4 Sqmm. XLPE insulated PVC sheathed armoured copper conductor cable of 1.1 KV Grade confirming to IS:7098 (Part 1) with upto date amendment etc. complete as required. 47 Supply, Installation, Testing and Commissioning of following 5 H.P. 3 Phase 100 mm water cooled Borewell Submersible pump set- with associate accessories. 48 Supply, Installation, Testing and Commissioning of following 5 H.P. 3 Phase 6-10A DOL water cooled Borewell Submersible Pump Starter with associate accessories. 49 Supply, Installation, Testing and Commissioning of following sizes of CI butterfly valve conforming to API-594 with C.I. body, SS Disc, SS stem, EPDM seal, complete with companion flanges, bolts, nuts, washers & inserted rubber gasket complete as required 50 150 mm dia. 51 100 mm dia. 52 80 mm dia. 53 Supply, Installation, Testing and Commissioning of following sizes of C- class heavy duty Mild Steel pipes conforming toIS-1239/ IS-3589, including cutting, welding, nut-bolts, gasket, fitting viz. bends, tees, reducers, crosses, flanges etc. and fixing the pipes onwall / ceiling / beam / floor with suitable MS clamps / structural supports/PCC block and painting complete as required and as per enclosed specification. 54 150 mm dia. 55 100 mm dia. 56 80 mm dia. 57 Supply, Installation, Testing and Commissioning of MS structural support for Above ground piping and pump room manifold 58 Supply of fracture bed designed to provide firm, even support for patients with fractures. Bed to be made of mild steel with a powder-coated finish having features for allowing for changes in height and position and includes wheels for easy mobility within the hospital setting 59 Supply of healthcare semi fowler bedmade of mild steel with a powder-coated finish having feature to bend bed from mid. 60 Supply of suitable semi fowler 2 section mattress for healthcare bed with minimum 4inch thickness. The mattress to have non hygroscopic outer cover which is easy to clean such as artificial leather cover.
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 7
Madhya Pradesh View Result →
11.
Defence #9977989 AOC
Tender For Provision Of Guard Room With Allied Infrastructure Under Age B/R Iii At Chandi Mandir.; 1 Surface dressing n.exc 15cm deep in hard dense soil complete all as specified and directed 2 Excavation in trenches in hard/dense soil not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth for foundation etc. or for shafts, wells cesspits, manholes, pier hole etc. and getting out, complete all as specified. 3 Returning filling in including spreading, levelling, watering and well ramming in layers not exc.25cm thick each layer of soil all as specified. 4 Removal excavated soil to a distance exceeding 50 metrebut n.exc 250 metre and depositingwhere directed at a level not exceeding 1.5 metreabove the starting point complete all as specified & directed. 5 Excavation over areas in hard/dense soil not exceeding 1.50 metre in depth and getting out complete, all as specified. 6 providing cement concrete type D2, 1:4:8 using 40 mm graded stone aggregate,as in foundations, filling and mass concrete etc., complete all as specified and as directed 7 Reinforced cement concrete,type A-1, 1:1½:3(nominal mix), using 20mm graded crushed stone aggregate) as in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed 8 Reinforced cement concrete,type A-1, 1:1½:3(nominal mix), using 20mm graded crushed stone aggregate) as in Columns, pillars, piers, posts and struts complete all as specified and directed. 9 Reinforced cement concrete,type A-1, 1:1½:3(nominal mix), using 20mm graded crushed stone aggregate) as in Chajja and similar works, all as specified. Note: Reinforcement and form work shall be measured and paid separately 10 Reinforced cement concrete,type A-1, 1:1½:3(nominal mix), using 20mm graded crushed stone aggregate)as in Beams, cantilevers, bressummers, lintels over 1.5m span ,all as specified and directed. 11 Reinforced cement concrete type A-1, 1:1½:3(nominal mix, using 20mm graded crushed stone aggregate) as in slabs supported on walls, beams etc, shelves and the like complete all as specified and directed (reinforcement shall be measured and paid for separately). 12 Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter , all as specified and directed. 13 Formwork to sides of pillars, posts, struts, piers, columns and stanchionsrough finished surface of flat concrete complete all as specified and directed. 14 Form work to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. for roughly finished flat surfaces of concrete, all as specified. 15 Form work to soffits of suspended slabs such as roof slabs rough finished surface of concrete flat not exc 200mm thick complete all as specified and directed. 16 Form work to edges of concrete flats, treads, break in floors, window cills, concrete railings, openings in concrete walls, floor and roofs exc 20cm wide and side of RCC / PCC bends in walls , horizontal or sloping and similar work. 17 MS TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hoping for columns, hookingends and binding with mild steel wire (annealed ) not less than 0.9 mm dia or securing with clips completeall as specified and directed. 18 Mild steel TMT bars 6 to 8mm dia and over, cut to length, bent to shape required, including cranking, bendingspirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia. or securing with clips complete all as specified & directed.(Stirrups) 19 Brick work with sub class ‘B’ bricks, straight or curved on plan exc 6 metre mean radius built in cement mortar 1:6 complete all as specified & directed. 20 Brick work with sub class ‘B’ bricks, straight or curved on plan exc 6 metre mean radius built in cement mortar 1:4 complete all as specified & directed. 21 Brick work with sub class ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4 complete all as specified & directed. 22 Rendering 15mm thickin Cement and Sand mortar 1:4 over brick or concrete surfaces finished even and fair without using extra cement complete, all as specified and directed. 23 Rendering 15mm thickin Cement and Sand mortar 1:6 over brick or concrete surfaces finished even and fair without using extra cement complete, all as specified and directed. 24 Rendering 5mm thick in CM 1:3on fair faces of concrete/brick surfaces as in ceiling, chajja, facia or similar positions , finished fair and smooth complete all as specified and directed. 25 Earth filling under floor including spreading and levelling in in layers n.exc 25cm thick complete all as specified & directed. 26 Hard core ofbroken stone or boulders of gauge n.exc. 63mm, deposited, spread and leveled in layers n.exc. 15cm thick, watered and rammed to a true surface complete all as specified & directed. 27 75mm thick PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) as in sub base etc, finished even and rough complete all as specified and directed. 28 75mm thick plain cement concrete type C-2 1:3:6(Using 40mm graded crushed stone aggregates) as in plinth protection finished even and smooth without using extra cement complete all as specified and directed. 29 25mm thick PCC 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) as in flooring, finishedeven and faircomplete all as specified and directed. 30 Non skid ceramic coloured tiles7 to 8 mm thick area of each tile exc 0.18 sqm but not exceeding 0.38 sqm, in floors etc., set and jointed in neat cement slurry and pointed in white or Coloured cement to match over and including 15 mm thick screed bed in cement mortar 1:6, complete all as specified and directed. 31 Glazed ceramic coloured tiles of size 300mmx450mmx 7mm thick as in dado, set and jointed in neat cement slurry and grouted in white cement complete as on vertical surfaces over and including 10mm thick bedding layer in CM 1:4complete all as specified and directed. 32 20mm thick Granite work (of any type table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like, set in 20mm thick screed bed in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite compelte including moulding on front edgeall as specified and directed. 33 Supply only integral water proofing compound complete all as specified & directed. 34 Steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded including one coat of red oxide primer etc complete all as specified and directed. 35 Framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forget into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 290-0 or Fe 165-0,all as specified and directed. 36 Sheet glass 4mm thick, ordinary quality and glazing with oil putty in square, area not exc 0.5 sq. mtr in each pane,complete all as specified and directed. 37 Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of size 30mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-in- Charge 38 Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 45 x 70 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately). 39 Pressed steel frames 125mm x 60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc,including filling of PCC 1:3:6 in hollow frame complete all as specified and directed. 40 Factory made second class hard wood 35mm thick Plain framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressuretreated, all as specified and directed. 41 35mm thick of second class hard wood glazed and Skelton shutteropen rebated & prepared to receive glass, gauge etc (without sash bars), edges of framing plain chamfered or rounded, fitted with cut & mitred beads for securing glass etc.; Size of members of shutters as specified in SSR Part 1, Section 8, clause8.24 (a); supplied and fitted to chowkats complete all as specified and directed. 42 Stainless steel butt hinges, 100mm long fixed to steel chowkhats by welding, bolting, rivetingetc, complete all as specified & directed. 43 200 mm size aluminium , barrel tower bolt of extruded section and fixed complete all as specified and directed. 44 150 mm aluminium handles cast typecomplete all as specified and directed. 45 Supply and fixing aluminum alloy, anodized, sliding door bolt 250mm long hasp , staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminum alloy and fixed complete all as specified and directed. 46 Steel windows , ventilator fixed type with glazing bars, including one shop coat of red oxide zinc chrome primer, complete all as specified & directed. 47 Galvanised mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18 mm and fixed with stainless steel wire staples, complete all as specified and directed. 48 Preparation of new plastered surfaces of walls and applying two coats of oil bound distemper over a coat of primer complete all as specified and directed. 49 Preparation of new plastered surfaces of ceiling and applying two coats of oil bound distemper over a coat of primer complete all as specified and directed. 50 Preparation of new plastered surfaces of walls and applying two coats of cement base paint, complete all as specified and directed. 51 preparation of new wooden surfaces and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed. 52 Preparation of new steel surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint complete all as specified and directed. 53 RCC pipes class NP2200mm dia bore, with collars, ISI marked, jointed with cement mortar, laid in trenches and tested including fittings of same grade complete all as specified and directed. 54 Plain cement concrete type C-2, 1:3:6 using 40mm graded crushed stone aggregate as in bed to drain pipes including cradle of pipe after the pipes are laid and tested , complete all as specified and directed. 55 PVC(SWR) rain water pipe, 75mm bore, single socketed in any length with rubber ring joints, laid in trenches or in floors,complete all as specified and directed. 56 PVC(SWR) rain water pipe, 110mm bore, single socketed in any length with rubber ring joints, laid in trenches or in floors,complete all as specified and directed. 57 75mm bore PVC (SWR) bend any radius complete all as specified and directed. 58 110mm bore PVC (SWR) bend any radius complete all as specified and directed. 59 PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement complete all as specified and directed. 60 PVC (SWR) floor trap 100mm bore, plain with grating including jointing with solvent cement, complete all as specified and directed. 61 Steel water tubes, 15mm dia bore, medium grade, galvanized, with and including all fittings and fixed complete to walls ceiling or laid in floors, complete all as specified and directed. 62 Steel water tubes, 20mm dia bore, medium grade, galvanized, with and including all fittings and fixed complete to walls ceiling or laid in floors, complete all as specified and directed. 63 Cutting chases in brick walls, pinning in, making good to facings where required and pointing in cement mortar (1:3) to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc and cutting chases for concealed water tubing or concealed conduit wiring etc and making good, cutting not exceeding 10cm girth Complete all as specified and directed . 64 Vitreous china squatting pan orissa pattern,size 580 x 440 mm white, with integral foot rest including P or S trap, flush pipe (excluding flushing cistern) and making good to the floor complete all as specified & directed by Engineer-in-charge. 65 Vitreous China Wash down water closet (pedestal pattern) , white, with and including PVC seat cover, complete all as specified and directed. 66 PVC valve less syphonic action flushing type flushing cistern low level white with PVC in let ball valve, float and handle, 10 ltrs capacity and connection to pipes including 32mm dia PVC bend for squat pedastal pattern ,complete all as specified & directed. 67 Vitreous China wash basin, angle back, size 600x480mm white, excluding taps, waste, chain and plug and porcelain stopper butincluding brackets complete, all as specifiedand directed. 68 Bib tap, fancy typecast copper alloy, chromium plated, screwed down, high pressure with crutch or butterfly handle, screwed both and for iron pipe or for union,suitable for 15mm bore pipe, complete all as specified and directed. 69 Wall mixer, mix for mixing hot or cold water, chromium plated suitable for 15mm bore GI pipe or union,complete all as specified and directed. 70 Stainless steel grating 127mm complete all as specified and directed. 71 PVC connections 15 mm size with PTMT nuts of length 450 mm , complete all as specified and directed. 72 32mm dia PVC waste pipe with PTMT nut, complete all as specified and directed. 73 Towel rail 600mm long ofPTMT fixed with and including chromium plated brass screws and wooden / plastic cleats (minimum weight 190gms),complete all as specified and directed. 74 Soap dish of cast copper alloy, chromium plated (CP),complete all as specified and directed. 75 Chromium plated, fancy type shower rose with swivel joints 125mm dia with arm and fixing to steel pipe 15mm bore, complete all as specified and directed 76 Angular stop cock, fancy type, cast copper alloy chromium plated, screwed down,screwed both and for iron pipe or for union, suitable for 15mm bore pipe,complete all as specified and directed. 77 Stop valve, cast copper alloy, screwed down, high pressure with crutch or butterfly handle, screwed both and for iron pipe or for union, suitable for 15mm bore pipe, complete all as specified and directed. 78 health faucet (ABS body) mild steel chromiu plated for 15mm dia pipe with 1.25 metre long flexible tube and ABS wall hook incuding making connections and fixed in position,complete all as specified and directed. 79 Sheet glass shelf assembly consisting of 5.5mm thick sheet glass 12cm wide with CP bracket guard and railing 60cm long,complete all as specified and directed. 80 Toilet paper holder, stainless steel, chromium platedfixed in position, complete all as specified and directed. 81 1000 litres capacity rotational moulded polyethylene water storage tanks (Cylindrical vertical with closed top) double layered, screwable lid, hoisted and fixed in position, including tank nipple, float valve, ball valve 20mm PTMT, complete all as specified and directed. 82 Bevelled edge mirror size 600mm x 450 mm, 5mm thick of selected quality glass mounded on 5 mm thick PVC board fixed to wooden plugs with chromium plated brass screws and cup washer with aluminium channel of suitable section alround ,all as specified & directed. 83 Urinal spreader of PTMT any colour for fixing with 15 mm dia pipe. (Minimum weight 60gms) complte all as as specified and directed 84 Vitreous China Urinal, Half stall type, white and including flushing cistern, flush pipe and waste pipe,complete all as specified & directed 85 Precast concrete interlocking paver block, with grey cement and no pigment, design as approved, any shape and size conforming to IS 15658-2006 of 60 mm thickness, M-35 Grade, and including laid over 25mm thick sand cushioning,complete all as specified and directed 86 3mm thick Atactic polypropylene polymer (APP) based polymeric membrane minimum weighing 3kg/sqm andreinforced with polyester non woven fabric (weight not less than 150 gms/sqm) laid over a coat of oil bound bitumen primer @0.40L/Sqm by same membrane manufacturer of density 0.87 to 0.89 kg/L at 25° C temperature and viscosity 70 to 160 CPS. The membrane shall be laid using butane torch and sealing all joints etc having 75mm side lap joint and 100m end lap joint after preparing the surface as per standard practice and as per manufacturer instructions and finished with applying one coat of bituminous aluminium paint @100gm/sqm on top of membrane, complete all as specified & directed. 87 15mm thick rendering in Cement and Sand mortar 1:4 over roof slab and sunken portion finished even and fair mixed with water proofing compound, including dimantling of the existing roof slab / suken portion complete all as specified. (NOTE : WPC will be measrued and paid separately) 88 Point wiring with approved colour code multi stranded copper conductor, PVC insulated and unsheathed FRLSH cable of size 1.5 Sqmm ,1100 volts grade, two run of single core cable for phase & neutral and one run of single coremulti stranded copper conductor, PVC insulated and unsheathed FRLSH cable of size 1.5 Sqmm ,1100 volts grade for earth continuity conductor to common earth and connected to earth dolly in and including new concealed PVC conduit terminated on and including new modular sunken box and suitable size of frame, cover for mounting switch, socket and regulator fixed on surface flush with wall , comprising ofOne light /bell/buzzer point controlled by one switch or one fan point controlled by one switch &fan regulator, complete all as specified and directed. Note : Unit rate is inclusive of making good the disturbed surfaces by provding by wall putty/POP after mason work and finshing to match the original and nothing extra shall be paid on this account.Note :Unit rate is inclusive of cutting chases in wall /foor/PCC and making good the disturbed surfaces to match the original and nothing extra shall be paid on this account. 89 All as per serial item 88 herein before but for socket outlet 3 pin 5 Amps on same board complete all as specified and directed 90 All as per serial item 88 herein before but for socket outlet 3 pin 6 Amps on independentboard complete all as specified and directed 91 All as per serial item 88 herein before but One socket outlet three pin ,6/16 Amp, independent board, with 2.5 Sqmm (nominal area ) FRLSHcable & 2.5 Sqmm (nominal area ) cable as earth continuity conductor 92 Switch modular type (ISI marked), single pole, one way 6 Amps, one module(ISI marked), complete all as specified & directed. 93 Switch modular type (ISI marked), single pole, one way 16 Amps, one module(ISI marked), complete all as specified & directed. 94 Socket shutters outlet 2/3 pin 6 Amp modular type multi purpose two module (ISI marked), complete all as specified & directed. 95 Socket shutters outlet 2 in 1 pin 6/16 Amp modular type multi purpose combined 2 module (ISI marked), complete all as specified & directed. 96 Modular switch type stepped fan regulator, single pole, 230 volt two module complete all as specified and directed. 97 Ceiling rose, PVC or polycarbonate of size 65mmx50mm three terminals (ISI marked) all as specifiedand directed by Engineer-in-charge. 98 Lamp holder, PVC/Polycarbonate type with back plate modular type fixed on wall suitable for batten fitting ,complete all as specified and directed. 99 LED lamp9 watts, B-22 type complete all as specified . 100 MCB DB, IP 43 protection, powder coated double door with locking arrangement suitable for surface and flush mounting,04 way SPN with 200 Amps busbar 240V completed all as specified and directed. 101 MCB , TPN/FP 40 to 100 Amp 415 volts, 16 KA , C series including connection with suitable size aluminium / copper lugs complete all as specified and directed 102 MCB ,SP , 240 volt, 6Amps to 32Amps, 10 KA , C series including connection with suitable size aluminium / copper lugs complete all as specified and directed 103 Single pole and neutral enclosure with a two pin and earth plug and socket complete with 20 Amp MCB C series single pole complet all as specified and directed. 104 LED lights fitting 1x 20W, 220V,AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose completecomplete all as specified and directed. 105 LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable sizecomplete all as specified and directed. 106 LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver,includinglamp bracket upto 1.5metre length as per suitable for fitting including clamp with impact and corrosion resistant including thermal management in multiple optics complete with IP 66 protection,complete all as specified and directed. 107 Sub main wiring with two singlecore FRLSH PVC insulated and unsheathed cable with copper conductor of size 4 Sqmm (nominal area), 1100 Volt grade(with approved colour coding as per IS) with and including continuous earth wire of size 4 Sqmm PVC insulated and unsheathed FRLSH multi stranded copper conductor 1100 volts grade , and connected to main board drawing throughPVC concealed conduit 25mm size(minimum size), cutting chases in walls for PVC concealed conduit and making good the disturbed surfacesby providing by wall putty/POP after mason work and finshing to match the original surfaces and nothing extra shall be paid on this account all as specified and directed.NOTE : -(i)Two runs of cable, one run of earth wireshall be considered as one running metre(ii) Cutting chases and conduit will be measured and paid separtely(iii) colour code shall be Red for phase, Black for neutral and green for earth 108 Cutting chases in brick walls, pinning in, making good to facings where required and pointing in cement mortar (1:3) to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc and cutting chases for concealed water tubing or concealed conduit wiring etc and making good, cutting not exceeding 10cm girth Complete all as specified and directed . 109 25mm dia, rigid non metallic PVC concealed conduit, ISI marked, inclusive of all fittings (such as junction boxes, bends, elbows, tees, reducers, bell mouth tube ends) and all fixing accessories such as couplers lock nuts, saddless, pipe hooks etc for wiring, Complete all as specified and directed . 110 Exhaust fan, steel body AC single Phase. 230V of size 300mm sweep , 1400 rpm, heavy duty with, blades, and frame and louvers including grouting nuts, fastners and provision of flexible coper cable 3 core form ceiling rose to exhaust fan complete all as specified and directed. 111 Supply, installation, commissioning of water cooler partially stainless steel, electric driven single phase having approx storage and nominal cooling capacity 40/40 ltrs complete all as specified and directed. 112 Ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) and provision of flexible copper cable 3 core from ceiling rose tofan complete all as specified and directed. 113 Earthing complete with galvanized steel earth plate electrode 60cmx60cmx6.00mm thick, burried directly in ground vertically to a depth not less than 2.25m below normal ground level, with top edge of the plate not less than 1.5m below normal ground level, earth plate surrounded by 15cm thick and packed alternate layers of charcoal dust and common salt, connected with and including earth lead of GI wire 4mm dia (8 SWG) by means of bolts, nuts, check nuts and washers of galvanized iron or thimbles and other end of the earth wire connected to main switch board and protected by galvanized iron pipe light grade 15mm dia bore including watering pipe 20mm dia bore GI light grade (ISI marked) with funnel and wire mesh, including all necessary excavation and earth work, PCC chamber in plain cement concrete (1:3:6) type C-1 and pit cover of presast RCC with MS frame etc and all as shown in electrical plate No 3 of MES Sch Part-I (2009), complet, all as specified and directed. Note(s) :-(i) RCC pit cover shall be pre-cast of RCC (1:2:4) type B-1, 80mm thick reinforced with XPM not less than 4Kg/Sqm.(ii)PCC chamber shall be constructed 500 mm away from the edge of earth pit.(iii) Rate shall include earth lead and protection pipe of length 7.5m(iv)Earth resistance should be less than 3Ohm. In case the test results are not found below 3Ohm, complete earthing will be redone without any extra cost to Govt.(v) unit rate including protection pipe and GI wire 4.00mm dia from top to earth plate upto 7.5 meter 114 Electric water heater(vertical type geyser), capacity 25 litre, 2 KW BEE 5 Star rated AC single phase, including MS glass lined inner tank, glass coated heating element, high density PUF insulation, Anode rod protection, heavy duty fastner not less than 100mm with suitable size of nut & washer grouted in wall with complete mason work for proper mounting of geyser fastner bolts with all accessories such as safety valve, thermostat, NRV, connection piece etc. making necessary inlet / outlet water connection, testing on load complete all as specified and directed. 115 Supply and installation evaporative desert coolers (steel body) factory made 22/24 gauge PGI sheet of size100x70x60cm appx, front and side panels are made of same gauge with wood wool pad shaving nominal air flow capacity of 4000 cfm, or nearest size, having exhaust fan motor with copper winding of capacity 280 to 310 watt with 18” steel blade size, and submersible pump of capacity 1.5m head , and powder coated, with all fittings and fixtures as directed by Engr-in-Charge onsite complete all as specified and directed.”(Make-Champion or equivalent.) Note :- The rates are included of material and labour for Fabrication cooler stand size 60x70x80cm ( LxWxH) angle iron of 35x35 x 5mm as directed conforming to Fe-290Gde E-165, including cutting, welding, cross support in upperside and lower side with flat iron or angle iron of 35x35x5 etc, two coats synthetic enamelpaint over one coat redoxide primer, installed in location complete all as specified and directed. 116 32mm outer dia, double walled corrugated (DWC) HDPE duct pipe pipes of pressure rating 6 kgf/sq. cm conforming to IS 14930 Part-II with anti rodent and non flame propogating properties of approved colour with fittings for cable protection as approved by Engineer-in-charge complete , all as specified and directed 117 Supply and laying XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 16sqmm, 2 core, laid in trenches , sleeving through pipes of fixed on poles & wall or laid under floors inlcuding jointing with suitable size of alumunium lugs as specified and directed.
Contract Date: Feb 24, 2026 Contract Value : 23.03 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 2
13.
Educational and Research Institute #9817217 AOC
Tender For Electrical Works Of Sps & Sps Lab In Block-B At Iop, Bhubaneswar; 1 M.V. PVCA/XLPA CABLES: Supply, installation testing & commissioning of 1.1KV grade PVC/XLPE insulated, inner sheath tapped, outer sheath PVC extruded, GI strip/armored, multi stranded/ Aluminum conductor power cable as per IS 1554 specifications, FRLS grade anti-rodent and anti-termite PVC (ST-2) outer sheathed cable, in ground at a depth of 900mm below ground level, sand bedding, laying of baked bricks on side and top, temporary reinstatement, back filling, dewatering, consolidation, disposal of excess earth within the radius of 500m and making good to the original finish etc. orfixed on wall/column/slab/in existing GI Cable trays/hume pipes/ trenches by 5mm thick GI spacer fixed/coach screws/anchor fasteners in brick/stone wall /column/slab with 2mm thick GI saddle, all fixing accessories etc. complete including painting of saddle /flat/angle iron etc. The space between two supports shall be generally 600mm Etc. all as per the instructions of Engineer-in-charge-IOP.The tinned copper earth wires to be laid along with the cables should be painted with two coats of black bituminous compound for earth wire in ground & Jointing of the earth wire shall be solder joints with tinned copper cable sockets & GI nuts & bolts.Note: Scope includes all types of masonry work required making good to its original finish of holes through wall, slopes etc. after laying of the cable. Make of cables: Finolex/Polycab/CCI or approved equivalent of the same. 2 01 no x 3 ½ core x 185 Sqmm Al. PVCA/XLPE cable and 01 nos. of 8 SWG tinned copper earth wire. (From Block-B main panel room to UPS Incoming Panel)Holes in tiles provided on the walls is to be made of suitable size to draw the cables inside the Lab using the cutting machine and without damaging the tiles and aesthetic look of the room should be protected. 3 01 no x 4 core x 25 Sqmm Al. PVCA/XLPE cable and 01 nos. of 8 SWG tinned copper earth wire. (From 120KVA UPS output DB to Furnace Room (03 run-45+45+45) +XRD Lab-35+ Chemical lab-55 + PL Lab30+ Tool room-10)Holes in tiles provided on the walls is to be made of suitable size to draw the cables inside the Lab using the cutting machine and without damaging the tiles and aesthetic look of the room should be protected. 4 DISTRIBUTION BOARDS: Supply, Installation, testing & commissioning of following medium voltage (415V) TP&N/ SP & N distribution boards single door complete with necessary SFU, MCCB, MCBs, etc. suitable for wall mounting with M.S. frame work of 40x40x5mm angle mounting with M.S. enclosure fabricated out of 16SWG thick M.S. CRCA sheet with concealed hinged door, cam type locking arrangement, dust and vermin proof with IP-42 protection, Front operated front access, all live parts shall be shrouded, all bus bars shall be insulated with heat shrinkable sleeves, SMC/DMC shrouds and Bus bar supports shall be used etc. Suitable tinned copper bus bars have to be provided for all phases, neutral and earth connections both for incoming and outgoing connections.Cable end box, wire way box, including interconnections with appropriate size of PVC insulated copper conductor, phase barriers, earth of DB, enameled danger board, name plate, neoprene gasket for joints & door has to be provided. Necessary metal treatment, two coats of red oxide paint & Powder coated with color shade of RAL 7032. A suitable Bakelite sheet with necessary cutouts for knobs/ operating levers of MCB’s/ MCCB/ SFU etc is to be provided duly fixed on to the cabinet with nuts and bolts/ screws. The front door (MS sheet) should have the name of the DB in anodized aluminum plate. Phase distribution drawing etc. all as per drawings specifications etc. relevant IS & instruction of Engineer-in-charge (G.A. & fabrication drawing to be got approved before fabrication)Note: 1.MCB’s shall be minimum 10KA breaking capacity2. All tinned copper bus bars should be minimum of 200A rating or more than that as mentioned in the drawing.3. All SFU units should have to be provided with HRC fuses4. Make of SFU: L & T, Siemens, or approved equivalent of the same & make of MCB: Legrand or approved equivalent of the same.5. All feeders including the Incoming are to be provided with proper nomenclature in anodized Aluminium plates near the MCB, output terminals & on DB as per requirement/ as per instruction of EIC.6. All terminals inside the DB has to be provided with suitable copper lugs/sockets for connection.7. For the feeders above 125A rating output connection is to be made directly from the Bus bars and the output bus bars has to be extended suitably to the cable bay box for connection of the output cables.8. Suitable Copper Tinned Bus-bar has to be provided for the running earth in each DB.9. The DBs are to be fabricated in electrical panel fabrication shop approved by Institute of Physics. The DBs will be inspected by our EIC in 3 stages and for which it has to be informed accordingly. 5 Main Incoming DB (Located in UPS room). a) 250A TPN SFU for In-comer -01no.b) 200A TPN SFU for outgoing (120KVA UPS) -01noc) 100A TPN SFU for outgoing (Spare) – 01 no.d) 32A TPN MCB for outgoing (4TR cassette AC units) – 03 nos. e) 63A TPN MCB for outgoing (Spare) – 01 no.f) 32A DP MCB for (Tool room Sockets) – 01 no.a) 32A DP MCB for (Spare) – 01 no.b) 0-500V Voltmeter with 3 way & off selector Switch and HRC Fuse carrier with fuse – 01 setc) RYB LED type indicating lamps with HRC fuse protection – 01 set 6 120KVA UPS Output DB (Located in front of UPS Room): a) 200A TPN SFU with 160A Fuse for In-comer -01no.b) 125A TPN SFU for output (SPS).c) 125A TPN SFU with 100A Fuse for output (Furnace Room).d) 63A TPN SFU (Furnace Room +XRD Lab+ Chemical lab + PL Lab) – 04 nos. e) 32A TPN SFU (Tool room) – 01 nos.f) 32A DP MCB (SPS Room-02 + Tool Room-02) – 04 nos.g) 16A DP MCB (Scholar Room) – 01 no.h) 32A DP MCB for (spare) – 01 no. 7 Furnace Room UPS DB (Located in Furnace Room)a) 125A TPN SFU with 100A fuse for In-comer -01no.b) 63A DP MCB (10KW Furnace) – 01 no.c) 25A DP MCB (04KW Furnace) – 03 nos.a) 20A DP MCB (03x15A Socket) – 01no.b) 16A DP MCB (02KW Furnace) -01 no.c) 32A DP MCB (Spare) – 01 no. 8 Incoming TPN SFU (Located in Block-B main panel room) The panel will be wall mounting type and will contain the following items:1. 250A TPN SFU with Fuse – 01 nos.Note:There should be sufficient length of Copper Bus Bar and end termination space for connection of the followingcables: Incomer-1 - 1x 185Sqmm XLPE, Armored, 3 ½ Core cables (From Block-B main Panel room i.e. Normal supply) Outgoing–1 - 1x 185Sqmm XLPE, Armored, 3 ½ Core cables (To Normal DB SPS Lab) 9 END TERMINATION OF ARMOURED CABLES:End termination and connection of the following cables by crimping with supply of all jointing materials like tinned copper cable sockets, cable glands, gland earthing insulation tape, flux, duplicate interconnection between gland earthing strip and the nearest earthing bus terminals as per the drawing, specifications, Aluminum cable tag is to be provided with each end termination and all as per the instruction of the Engineer in charge. Make of lugs/sockets: Dowels/Jainson 10 3 ½ core x 185 Sqmm Al. PVCA /XLPE cable 11 04 Core x 25SqmmAl. PVCA /XLPE cable 12 FLEXIBLE CABLES/WIRES:Supply, installation, testing and commissioning of 1100V FRLS grade, ISI marked, PVC insulated multi stranded copper conductor (flexible) wires/cables. The wires/cables will be laid and fixed on the wall with suitable GI clamps (04 runs in one bunch)/ connected as per the instruction of the EIC.Note: Scope includes supply and to provide the binding tags wherever it is required to bind together more than one wires/cables being laid in the same line and supply, crimping of 70Sqmm Ring type copper socket (16nos.), connection of the same to the required terminal.Make: Preferably Polycab/ Finolex or approved equivalent of the same. 13 70 Sqmm x Single core FR, PVC insulated copper conductor flexible wire 14 Wiring in PVC Casing & Capping:Supply Installation, testing & commissioning of 1100V FRLS grade PVC insulated multi stranded copper conductor wires in suitable PVC casing & capping with double interlock, meeting with IB/IS specification. Arrangements to be made for holding the wires in position in trunk, on (Aluminum Plate running on wall of plywood partition)/Plywood partition/ceiling/ concrete or brick wall with counter sunk tinned brass wood screw fixed with nylon plug etc. complete with all accessories like right angle bend, outer inner bend, T-stopper, PVC clamps (preferable) suitable pull boxes/ junction boxes of suitable size as per the site condition wherever required & with necessary leads at both ends by approved copper lug, complete as per the instructions of Engineer-in charge.Note:1. Connection shall be done with crimped type tinned copper lugs and washers.2. Casing & Capping should be white & make: Precision/Hensel/Asian & circle IS 14927 marked or approved equivalent of the same.3. All PVC insulated copper conductor FRLS grade shall be ISI marked.4. Make of wires: Finolex/ Polycab or approved equivalent of the same.5. It may be required to draw multiple wires in single PVC casing capping as per requirement. 15 03 nos. of 10 Sqmm wire in PVC casing & capping. 16 03 nos. of 04Sqmm wire in PVC casing & capping. (SPS Room-160+Tool Room-49+Scholar Room-15+Furnace Lab-62+XRD-20+Chemical Lab-25+PL Lab-100) 17 EARTH STATION:Supply, installation, testing & commissioning of tinned copper plate electrode earth station, 2.5 mtr. below ground level conforming to latest IS specifications complete with all required materials like coke/charcoal, salt, brass, nut bolts & washers, watering arrangements (GI funnel), G.I. pipe-25mm (B class), Brick, masonry chamber with PCC base, heavy duty cast iron cover plates (300x300mm) and excavation in all types of soil in ground, refilling and removal of excess earth within a radius of 500mtr etc. as per instruction of EIC-IOP, drawing & specification.Note:1. Measurement of resistance of earth station and resistance of complete scheme of earthing shall be measured, recorded & got approved by EIC-IOP. 2. The copper plate should be of electrolytic grade.3. Two nos. of 25 x 6 mm tinned copper flat is to be bolted to the earth plate and to be brought up to the top of pit. 18 600 x 600 x 3.15 mm tinned copper plate electrode earth station 19 EARTHING CONNECTION:Supply, laying/fixing, testing & commissioning of tinned copper earth wire fixed to wall side of trench/slab/column/beam/shaft with thick GI spacers and GI saddles or in ground at 750mm below including excavation in ground with protective baked bricks, excavation in ground refilling and back filling of trench, interconnection of earth wire /strip with GI nut bolts and washers and solder jointing, painting with two coats of black bituminous compound for earth wire/strip in ground as per the specifications and as per the instruction of Engineer-in-charge. Jointing of the earth wire shall be solder joints with tinned copper cable sockets 20 25 x 6 mm tinned copper strip to be laid in ground 21 25 x 6 mm tinned copper strip to be fixed on wall.(Scope includes supply and fixing of the suitable insulator for fixing the copper earth strip on concrete/ brick/ stone wall one at a span of 0.5mtr.). 22 MCB BOX: Fabrication, supply, installation, Testing and commissioning on concrete/brick wall of local control MCB box/Enclosure made out of 16 SWG thick galvanized MS sheet with top cover also galvanized MS sheet duly fixed by SS screws. Necessary cut outs to be provided on the top cover for the operating lever of the MCB and suitable size gland holes at two ends has to be made for the MS conduits/ PVCA/XLPE Cables. Readymade Legrand or approved equivalent make MCB enclosure box also can be provided. MCB shall be minimum of 10 KA breaking capacity. All complete as per the instructions of Engineer-in-charge.Note: All MCB should be of Legrand or approved equivalent make. 23 MCB Enclosure with TPN MCB of 63A rating 24 MCB Enclosure with TPN MCB of 32A rating 25 MCB box with DP MCB of 63A rating 26 MCB box with DP MCB of 25A rating 27 MCB box with DP MCB of 16A rating 28 OUTLET SWITCH & SOCKET BOXES: Fabrication, supply, installation, Testing and commissioning on concrete/brick wall/ plywood partition of outlet switch boards made out of 16 SWG thick galvanized MS sheet with top cover 3mm thick Bakelite Hylam laminated sheet duly fixed by SS screws. Necessary wiring inside the board has to be carried out using 04Sqmm copper PVC insulated single core flexible wire. One suitable nut and bolt has to be provided on the side wall of the board for earth connection. All complete as per the instructions of Engineer-in-charge.Note: 1. All switches, sockets & Plug Top should be of Anchor make or approved equivalent.2. All wires to be used should be of Finolex/ L&T make.3. All MCB to be provided should be of Legrand make.3. All terminals of the wires to be connected inside the board should be provided with suitable copper lugs/ sockets.4. Sample of all materials is to be got approved from EIC, IOP before execution. 29 Switch & Socket box with 03no.s of 5 Amp, 250Volt, 5pin socket & 03 nos. of 6Amp Switch. 30 Switch & Socket box with 04no.s of 15 Amp, 250Volt, 06pin socket & 04 nos. of 15Amp Switch. 31 Supply, Installation, Testing & Commissioning of TPN MCB- 32A in the existing Distribution Board.
Contract Date: Mar 17, 2026 Contract Value : 9.19 Lakh
Boards / Undertakings / PSU No of Bidders 4
14.
Educational and Research Institute #9417004 Technical Bid
Supply Of Consumables/Non-Consumables For The Department Of Pharmacology. Consumables/Non-Consumables For The Department Of Pharmacology. , Chemicals , Acetylcholine Chloride (Ar Grade) , Ammonia (Ar Grade) , Ammonium Acetate (Lc-Ms Grade)Sigma , Ammonium Thiocyanate Acs Grade , Ammonium Thiocyanate Ar Grade , Ascomycin (Reference Standard Powder) Sigma , Atropine Sulphate (Ar Grade) , Benzoic Acid Sigma Acs Reagent, >99.5% (Sigma) , Bismuth Sub Nitrate (Ar Grade) , Bratton Marshall Reagent (Ar Grade) , Calcium Chloride (Ar Grade) Powder , Carbamazepine(Analytical Standard) Sigma , Chloroform Hplc (Ar Grade) , Cobalt Nitrate (Ar Grade) , Concentrated Hydrochloric Acid (Ar Grade) , Concentrated Nitric Acid (Ar Grade) , Cyclosporine A(Analytical Standard) Sigma , Dextrose (Ar Grade) Powder , Diazepam (Analytical Standard) (Sigma) , Diclofenac (Ar Grade) , Edta (Ar Grade) , Ethanol Absolute , Ferric Chloride (Ar Grade) , Ferric Nitrate (Ar Grade) , Formic Acidlc/Ms Grade (98- 100%) , Glacial Acetic Acid (Hplc Grade) , Isopropyl Alcohol (Hplc Grade) , Magnesium Chloride (Ar Grade) Powder , Mercurric Chloride (Lr Grade) , Morphine Sulphate (Pure Powder) , Ninhydrin (Ar Grade) , Orthophosphoric Acid (Ar Grade) , Papaverine Pure Powder (Ar Grade) , Phenobarbitone (Phenobarbital) (Reference Standard Powder) Sigma , Phenytoin (Reference Standard Powder) (Sigma) , Potassium Chloride (Ar Grade) , Potassium Dihydrogen Orthophosphate (Ar Grade) , Potassium Hydrogen Phosphate (Ar Grade) , Potassium Hydroxide (Ar Grade) , Potassium Iodide (Ar Grade) , Potassium Permanganate(Ar Grade) , Pottassium Dihydrogen Phosphate (Ar Grade) , Quality Controls For Estimating Carbamazepine In Human Serum Using Uplc , Quality Controls For Estimating Cyclosporine In Human Whole Blood Using Lc-Ms , Quality Controls For Estimating Phenobarbitone In Human Serum Using Uplc , Quality Controls For Estimating Phenytoin In Human Serum Using Uplc , Quality Controls For Estimating Tacrolimus In Human Whole Blood Using Lc-Ms , Quality Controls For Estimating Valproic Acid In Human Serum Using Lc-Ms , Sodium Bicarbonate (Ar Grade) , Sodium Chloride (Ar Grade) , Sodium Hydroxide Pellets (Ar Grade) , Sodium Nitrite (Ar Grade) , Sodium Salicylate Powder (Ar Grade) , Sodium Valproate/Valproic Acid Sodium (Reference Standard Powder) (Sigma) , Strychnine Pure Powder (Ar Grade) , Sulfamic Acid (Ar Grade) , Sulphuric Acid (Ar Grade) , Tacrolimus (Reference Standard Powder) (Sigma) , Trichloro Acetic Acid (Ar Grade) , Valproic Acid- D6 Solution (Sigma) , Zinc Sulphate Sigma , Solvents , Acetonitrile Hplc Grade , Acetonitrile Lcms Grade , Ethyl Acetate (Ar Grade) , Glycerine (Ar Grade) , Methanol (Ar Grade) , Methanol (Hplc Grade) , Methanol (Lcms Grade) , Plastic Wares , 15Ml Pp Conical Bottom Tube (Tarson) (Pack Of 20) , 50Ml Pp Conical Bottom Tube (Tarson) (Pack Of 10) , Centrifuge Tube Rack (Polypropylene) - 15Ml Capacity (Min. 30 Places) , Centrifuge Tube Rack (Polypropylene) - 50Ml Capacity (Min. 10 Places) , Centrifuge Tube Stand (15 Ml Capacity) (12X3 Holes, Aluminium) , Cuvetes (Plastics) 2Ml , Membrane Filter, Nylon 0.45?, 47Mm (Pack Of 100) , Micro Tips (200-1000?L) (White) (Pack Of 1000) , Microcentrifuge Tube (1.5 Ml) With Flip Cap, Sterile, Pp (Pack Of 500) (Preferred Make; Abdos/Tarson) , Microcentrifuge Tube (2 Ml) With Flip Cap, Sterile, Pp (Pack Of 500) (Preferred Make; Abdos/Tarson) , Microtips (0.2 - 10 Ul) (White).(Pack Of 1000) (Preferred Make; Abdos/Tarson) , Microtips (2 - 200 ?L) (White).(Pack Of 1000) (Preferred Make; Abdos/Tarson) , Nitrile Gloves (Purple, Size-Large) (Pack Of 100) , Nitrile Gloves (Purple, Size-Medium) (Pack Of 100) , Pasteur Pipette - Plastic, 3Ml Sterile (Pack Of 100) , Screw Capped Polypropylene 2 Ml Storage Vials (Pack Of 100) , Stir Bar, Magnetic Teflon Coated, Reusable (8 X 30Mm) , Storage Bottles, Graduated, Clear With Pp Screw Cap And Pp Pouring Ring (Blue), Autoclavable Upto 140°C, Size: 1000Ml (Borosilicate Glass) , Storage Bottles, Graduated, Clear With Pp Screw Cap And Pp Pouring Ring (Blue), Autoclavable Upto 140°C, Size: 100Ml (Borosilicate Glass) , Storage Bottles, Graduated, Clear With Pp Screw Cap And Pp Pouring Ring (Blue), Autoclavable Upto 140°C, Size: 250Ml (Borosilicate Glass) , Storage Bottles, Graduated, Clear With Pp Screw Cap And Pp Pouring Ring (Blue), Autoclavable Upto 140°C, Size: 500Ml (Borosilicate Glass) , Syringe 1 Ml (With 0.1 Ml Grading) (Pack Of 100) , Syringe Filters 0.2Micron,Nylon 13Mm (Pack Of 100) , Syringe Filters 0.2Micron,Nylon 25Mm (Pack Of 100) , Inserts- 150?L With Polyspring For Lcms Vials (Waters Cat No.Wat094171) Or Equivalent (Pack Of 100) , Inserts- 300?L With Polyspring For Lcms Vials (Waters Cat No.Wat094170)Or Equivalent(Pack Of 100) , Glass Wares , 5L Measuring Jar , Beaker - 1000Ml (Borosilicate Glass) , Beaker - 2000Ml (Borosilicate Glass) , Beaker - 500Ml (Borosilicate Glass) , Beakers Glass 100Ml (Borosilicate) , Bottles, Reagent, Graduated With Screw Cap And Pouring Ring (250Ml) , Capillary Tube For Retro Orbital Sampling , Conical Centrifuge Tube (Glass) 15Ml (Pack Of 100) , Conical Flask (Glass) 100Ml (Pack Of 50) , Conical Flask, Size: 250Ml With Stopper (Borosilicate Glass) , Glass Jar (Tlc) 1000Ml , Glass Pipettes (10 Ml) (Pack Of 20) , Glass Pipettes (5Ml) (Pack Of 20) , Glass Pipettes (2 Ml) (Pack Of 20) , Glass Pipettes (1 Ml) (Pack Of 20) , Glass Stirrer , Glass Tubes20ml , Measuring Cylinder (Glass)100Ml , Measuring Cylinder (Glass)250Ml , Mercury Thermometer, 0 - 100ºc , Petridish , Test Tubes (12Mm X 75Mm - 5Ml) (Pack Of 50) , Small Instruments And Equipments , Micropipette - 100-1000Ul - Specifications: Should Work On A Click-Stop Digital System, Are Easy To Calibrate And Maintain, And Easy To Disassemble For Autoclaving. Calibration Certificate Must Be Provided With Each Pipette. Accuracy (±) %: 0.9 To 0.6, Precision (±) %: 0.3 To 0.2, It Should Be Ce Mark. , Micropipette - 20-200Ul - Specifications: Should Work On A Click-Stop Digital System, Are Easy To Calibrate And Maintain, And Easy To Disassemble For Autoclaving. Calibration Certificate Must Be Provided With Each Pipette. Accuracy (±) %: 0.6 To 1, Precision (±) %: 2 To 0.3, It Should Be Ce Mark. , Micropipette - 2-20Ul - Specifications: Should Work On A Click-Stop Digital System, Are Easy To Calibrate And Maintain, And Easy To Disassemble For Autoclaving. Calibration Certificate Must Be Provided With Each Pipette. Accuracy (±) %: 0.6 To 1, Precision (±) %: 2 To 0.3, It Should Be Ce Mark. , Micropipette 0.1-0.5 - Specifications: Should Work On A Click-Stop Digital System, Are Easy To Calibrate And Maintain, And Easy To Disassemble For Autoclaving. Calibration Certificate Must Be Provided With Each Pipette. Accuracy (±) %: 0.9 To 0.6, Precision (±) %: 0.3 To 0.2, It Should Be Ce Mark. , Micropipette 1-10 - Specifications: Should Work On A Click-Stop Digital System, Are Easy To Calibrate And Maintain, And Easy To Disassemble For Autoclaving. Calibration Certificate Must Be Provided With Each Pipette. Accuracy (±) %: 0.6 To 1, Precision (±) %: 2 To 0.3, It Should Be Ce Mark. , Heavy Duty Digital Vortex Mixer Specifications: 1. Bench Top Systemsuitable For Vortexingmultiple 1.5 Ml/ 2 Ml Tubes Simultaneously (Upto 24 Tubes) 2. Should Have Both Touch/ Pulsemode And On Mode 3. Should Have Both Time And Speed Display 4. Speed Requirements: 300 -3500 Rpm (On Mode) 5. Duty Rating Should Be Continuous 6. Electrical Requirements: 230V, 0.13A, 30W 7. Ce Certification 8. Required Accesories Should Be Provided. 9. Warranty: One Year , Aerator -Specifications: Aquarium-Type Aerator With Long And Intact Tubing System Minimum 3 Metres. , Precision Balance Specifications:1)Dynamic Weighing Mode – Allows The User To Weigh Small Animals And Filters Out Animal Movements To Provide A Stable Weight Indication.2)Single Block Technology Strong Anti-Shacking For The Highest Stability And Accuracy. 3)Single Touch External Calibration.4)Back-Light Led For Easy Viewing.6)Repeatability- +/-1 G 7)Scale Interval- 1 G 8)Linearity-1 G 9)Maximum Weighing Capacity- Atleast 5 Kg ; Minimum - 0.5G 10)Operating Conditions - Temperature+10 To +30 °C 11) Readability- 1G12)Warranty- One Year , Benchtop Digital Ph Meterspecifications: 1)Digital Led Display. 2)Ph Range: 0.00 - 14.00 3)Resolution:0.014) Working Temperature - 5 To 60°C 5)Accuracy (Ph)+- 0.05 6)Calibration: Minimum 2 Points For Automatic7)Electrode Stand: Holds 3 Standard Size Electrodes, Hand Free Simplified Sampling, Plastic Swing Arm And Quick Vertical/Horizontal Adjustment.8)2-4 Channels For Ph Measurements 9)Electrode + Standard Buffer Solutions (Ph 4.0, 7.0, 10.01 *200 Ml For Each Bottle) 10) Should Have A Data Storage Facility 11)Automatic Buffer Recognition 12) Operating Temperature- 10 - 40 Degrees Celsius 13) Warranty- One Year , Nova -Pak C18 (2.1X 10Mm Cartridge) Waters , Uplc Column (Shimpack Giss) (C18, 1.9?) (2.1 X 100 Mm) With Guard Column , Column Xbridge C18, 3.5? (2.1X 100 Mm) With Guard Column , Pole Climbing Apparatusspecifications:1)The Experimental Chamber Should Have A Grid Floor And A Sliding Door With A Clear Perspex Front, An Electronic Buzzer, And A Chamber Light. 2)A Solid-State Stimulator With A Built-In Timer Provides Electrical Shocks Of 400 V, 2 Ma At A Frequency Of 5 Per Sec. The Duration Of The Stimulus Should Be Controlled Manually Also. 3)Digital On And Off Timer- 1 To 100 S. 4)Digital Experiment Timer- 1 To 1000 S. 5)Accessories- Excreta Tray 6)Certification- Ce Compliant; Pole Material - Bakelight , Centrifuge - Specifications: Maximum Speed Of 5200 Rpm. Microprocessor Controlled Material - Ms Powder Coated. Double Walled Light Weight Abs Lid. Fitted With Microprocessor Base 2 Lines 16 Characters Lcd Panel For 0-59 Minutes Countdown Timer, Digital Rpm Meter And Programmable Speed Controller. Supplied With Swing Out Head 8X15 Ml. , Eddy’S Hot Plate (Hot Plate Analgesiometer) Specifications: 1. Heating Surface Approx. 30 Cm Diameter With Perspex Chamber. With Lid2. Digital Display.3. Temperature Range: 5°C Above Ambient To 60°C (± 0.2° C) 4. Reaction Time(Seconds)- Digital Timer Resolution Of 0.1S5. Min 1 Year Warranty6. Should Be Iso Certified. , Actophotometerspecifications:1)4-Digit Counter With Digital Readout For Evaluation Of Spontaneous Activity In Small Animals.Six-Pair Photoelectric Activity Sensors 2) The Cage Should Be Provided With A Top Cover And A Sliding Tray At The Bottom To Clean The Excreta Of The Animals. 3)Four-Digit Counter (With Zero Reset Facility) And Six-Pair Photoelectric Activity Sensors. 4) Counting On/Off Switch For Operation Of 230 V 50 Hz.5)Electronic Activity Digital Counter With Start, Reset And Stop Functions. , Analgesiometer (Tail Flick)Specifications: 1)Type- Radiant Heat 2)Digital Time Display (Tail Flick Method) With Foot Switch And Different Lab Animal Restrainer Size Brass 3)Material-Mild Steel 4)Conforming To Standard-Ce, Gmp Certified Product. 5)Surface Temperature-Deg C- 2-60 6)The Remote Foot-Switch Controls The Test Start/Stop 7) Microprocessor-Based System Required With Pc Connectivity; The Instrument Should Automatically Detect The Withdrawal Latency To The Nearest 0.1 S, Dedicated Data Acquisition Software Package, Lid Open Sensor, And Precise Programmable Digital Control. 8)Voltage- 220/280 V. Automatic Cut Off Time; Lamp , Electro Convulsiometer Specifications: 1.Should Have A Range Of At Least 0 Ma To 250 Ma Of Digital Current Intensity. 2. Should Have A Range Of At Least 0.1 To 10S Of Digital Timer. 3. Should Be Provided With Two Corneal Electrodes Of Size Approximately 4Mm, 5Mm & 6Mm Each And Two Specially Insulated Ear Electrodes Suitable For Small Rodents.4. Should Be Supplied With Foot Switch. 5. 1 Year Warranty Should Be Provided. 6. Should Be Iso Certified. , Rota Rodspecifications: 1. Should Be Usable For Both Mice And Rat 2. Should Be At Least Three Compartment Model. 3.Should Have The Lane Width Which Can Be Easily Adjusted For Mice And Rat 4.Should Have Detection Of Fall By Plate Type Sensor.5. Should Have Individual Lane Timers In The Range Of 0-990 Seconds With Resolution Of At Least 0.1S 6. Should Have An Electronic Rotor Speed Adjustment With A Constant Speed In The Range Of 0.1-75 Rpm At Least. 7. Should Have Provision For Easy Replacement Of Rotor. 8. Should Have At Least 3 Different Modes- Normal Mode, 2 Different Acceleration Modes. 9. Should Also Have Reverse- Forward Direction Selection Mode. 10. Should Have The Lane Width Of At Least 50Mm For Mice And & 70Mm For Rat. 11. Should Have The Falling Height At Least 220Mm For Mice & 230 Mm For Rat. 12. Should Have Rotor Diameter Of At Least 30 Mm. 13. Parameters Recorded: Distance Travelled In Centimeters, Falling Rpm And Time Spent On Rod. 14. Should Be Provided With Password-Protected Software For Data Collection. 15. Should Have Touch Screen Display With Functions Such As Password Protected System,Cut-Off Time, Auto Experiment Number, Password Protected Delete Mode. 16. Software Should Have Provision For Entering Experiment Title, Comments, Graphical Presentation Of Data And Assignment Of Test Id To Compartment For Animal Groups. 17. Software Should Have Pc/Laptop Connectivity 18. Software With Transfer Of Data To Excel, Report Generation In Excel Or Pdf, & Calibration Report Generation Facility. 19. Should Have Software With Provision To Add Title, Comment, Graphical Presentation And Data Can Be Exported To Pc/Laptop. 20. Should Provide 5-Year Warranty With 5-Year Cmc , Metabolic Cage For Small Rodents Specifications: 1. Metabolic Cages Should Be Designed For Perfect Separation Between Faeces And Urine2. The Cage Should Have A Floor Area Of 400 Cm²3. Metabolic Cages Should Be Made Of Clear, Durable, Washable And Autoclavable Clean Methyl Methacrylate (Mma) Material For Observation Of Animals.4. Floor Net, Feeder Net And Feeder Should Be Made Of Ss305. 5. The Water Bottle Should Have A Silicon Seal To Avoid Leakage And The Capacity Should Be 100-150 Ml6. The System Should Be Supplied Along With The Pee-Flowing Stool Bulb For Perfect Separation Of Faeces And Urine 7. Cage Size Should Not Exceed ( W * D* H) 150*150*150 Mm 8. Overall Size Should Not Exceed ( W * D* H) 220*220*450 Mm , Water Bath Specifications: 1) Rectangular Water Bath Double Walled Construction, Size Inside (Inner Reservoir- Stainless Steel) 300X250x100 Mm. 2) Outer Body In Mild Steel With Glass Wool Insulation In Between, Supplied With Lid Having One Hole Of `12.5 Cm Diameter And 6 Holes Of 7.5 Cm Diameter. 3)Concentric Rings With Lids Are Provided On Holes. The Top Plate And Concentric Rings Of Stainless Steel, Temperature Range Ambient To 100 Deg C.4)Controlled By Capillary Thermostat. 5)Capacity 8 Litres6) 230 A.C. Single Phase. 7)Warranty- One Year , Vortex Mixer:Specifications: Within 3O K 1. Speed Range 500-3000 Rpm, Options To Vortex Different Sizes Of Tubes (2-15Ml) With Speed Controlling Knob. 2. Acceleration Time – 3 Sec 3. Orbit-2Mm. 4. Power Supply: External Power Supply Dc 12 V, 500Ma 5. To Be Supplied With A Dc Adapter If Not Built In.6. Operation- Touch/Continuous7. Working Condition: 4 To 60°C Ambient 8. Product Ce Certified.9. Warranty Of Machine-Minimum 1 Year. , Mini Spin Centrifuge, For Laboratory Ideal For Microfiltration And Quick Spin-Downs. Specifications: Main Unit: 1. Compact, Lightweight. Mini Centrifuge (Non-Refrigerated) For Speed Up To 14,500 Rpm 2. G Value Should Be More Than 14,100 3. Rpm/ Rcf Settings Adjustable As Required 4. Rotor Imbalance Detection 5. Digital Display Of Speed 6. Should Confirm To Ce Ivd & Iec 1010-2-020 Safety Regulations. 7. Certifications Should Be Substantiated With Documentary Proof 8. Timer From 15 Sec To 99 Minutes With Continuous Function 9. Separate Short Spin Button 10. Metal Rotor Housing. 11. Brushless Motor 12. Acceleration To Reach Max Speed In <15 Sec 13. Braking Time Max. Speed <15 Sec. 14. Power: 230 V/ 50-60 Hz Rotors & Adapters: 1. Fixed Angle Rotor Should Be At 45 Degree 2. Rpm/ Rcf As Mentioned Above 3. Rotors And Lids Ptfe Coated 4. Aerosol Tight 5. Stain Less Steel Rotor Lid With Knurled Nut 6. Lid Latch Motorized 7. Auto Opening Of The Lid After The Run. 8. Autoclavable Rotors & Lids (121O C, 20 Mins) Two Rotors: 1. 1St Rotor: Standard Rotor With Lid 2. Capacity: 12 X 2 Ml & 1.5 Ml Microcentrifuge Tubes 3. Adapters For 1St Rotor: Adaptors For 0.2, 0.4, 0.5Ml & 0.6 Ml Microtainer Tubes = 12 Nos. Each 1. 2Nd Rotor: Pcr Strip Rotor With Lid 2. Capacity: 2 X 8 Pcr Tube Strip 15. After Sale, Service Should Be Available Promptly. , Digital Magnetic Stirrer With Hot Plate Specifications:1.Temperature Range : Above Ambient To 160°C 2. Speed: 100-1500Rpm 3. Heating Coil : Strip Heater 4. Temperature Controller : Digital 5. Temperature Accuracy: +/-5°C. 6. Construction: Mild Steel With Powder Coated Body. 7. Stirring Capacity: 2 Ltrs. 8. Stirring Speed : 100 To 1500 Rpm 9. Control : Feedback Control 10. Rpm Indicator : Analogue 11. Working Condition: 4 To 60°C. 12.Input Voltage : 230V, 50Hz. A.C. Supply 13.Maximum Stirring Capacity Per Position 5000.0 14.Number Of Stirring Positions - 1 15.Calibration - Manual Calibration 16.Option -Digital , Dissection Set , Forceps(Toothed) Medium , Forceps(Untoothed) Medium , Frontal Writing Lever , Kymograph Drum Paper , Oral Gavage Needle Disposable , Restrainer For Rabbits Specifications:1. Fully Adjustable Acrylic Rabbit Restrainer 2. Highly Polished Edges To Prevent Chafing, Especially At The Neck. 3. Non-Slip Surface For Better Footing 4. Curved Back Butt Plate 5. Vertical Head Bars (Adjustable) 6. Stainless Steel Pin Offers Several Fine Adjustment Points For The Neck Plate. 7. Autoclavable 8. Non-Slip Base Pads , Restrainer For Ratsspecifications: 1. Perspex Cylinders Mounted On A Flat Black Perspex Base 2. Flat Bottom Restrainer (Head And Tail Adjustable Type) 3. Weight Range (Rat): 125 G To 250G 4. Size: 2.5 X 6 , Rubber Bulb(Slicon Rubbermedium 5Ml) , Rubber Bulb(Slicon Rubbermedium 10Ml) , Scissors (Ss) Medium , Test Tube Holderfor15ml Tubes Standard , Others , Aluminium Foil (30Cm X 9Mtr) , Argon Special Gas Cylinder Refilling(Purity 99.9995) 5.5 Grade , Butter Paper For Measuring Salts , Edta Tubes 3 Ml (Pack Of 50) , Filter Paper Sheet (Ordinary) (60 X 60 Cms) (Pack Of 100) , Filter Paper Sheets(For Thin Layer Chromatography) , Nitrogen Cylinder Refilling , Silica Gel - G (Fine Powder For Tlc) (Ar Grade) , Small Animal Surgery Kit , Rectified Spirit , Teepol , Tissue Paper Roll (White)
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 8
15.
Science and Technology #9416314 Technical Bid
Provision Of Axle Counter For Rusty Rail And Siding Tracks In Balance Yard Of Bab-Agd Section Of Jhansi Division. , Installation, Testingandcommissioningofmultisectiondigitalaxlecounter(Msdac)Completesystemasper Rdso Specification Ino.Rdso/Spn/176/2013 Version 3 With Latest Amendments Or Latest. Suitable For Commissioning Of Yard/Auto Section / Dual Detection (Dctc/Aftc With Msdac) . Msdac Should Have Facility To Reset Track Sections. Design Of Axle Counter Circuit Indoor Installation Testing And Commissioning Of Multi Section Digital Axle Counter (Per Unit), Note-1:1.Ifanyhousingisrequiredtokeepoutdoorequipment,Ithastobesuppliedwiththe Equipmentwithnoextracost (Mushroom Box Will Be Supplied By Cel And The Installation Will Be Done By Vendor. If Any Additional Qty Of Mushroom Box I.E. More Than 107 Nos. Is Required Then The Cost Of Supply & Installation For The Same Will Be Borne By Vendor).2.Maintenancefreeearthing(Supplyandinstallation)Fortrack Device/Mushroomhousingetctobedonebythecontractorifrequiredbysystemdesign.Noextra Cost/Paymentwillbemadebythisrailway:3.Automaticresettingfacilitiesthroughhardware /Software For Auto Resetting To Be |Provided By Contractor By His Own Materials For This No Extra Cost /Paymentwillbemadeby Cel.4.Msdacsystemnetworkingtobedonewithcentralcontrol Room.E1 Channel/Media Will Be Provided By Railway For This Purposefromnearestrailwaystation.5.Allotherhardwareliketpr,Extracardtomakedualdp, Modem,Ethernetswitchesetcifrequiredforcommissioningandfinaltracksectionpickupwillbe Supplied By Contractor, No Extra Payment Will Be Made By This Cel. 6 Separate Evaluator For Up And Down Line To Be Provided At Station/Rh As Decided By Railway Site Engineer. For The Communicationbetweenevaluatortoevaluator(Rhtostation)Quad/Ofclink(Darkfiber)Willbe Provided By Railway. Any Other Networking Equipment If Required Will Be Supplied By Contractor At No Extracost.7.Manualresettingthroughresetbox&Lvboxatstationtobeprovidedasper Requirement.Thedpconfiguration/Tracksectionmayvaryaspersite Note : Testingandcommissioning Will Be Done By Oem , Supplyofdoublewalledcorrugated(Dwc)Pipe/Ductwithassociatedcollarsetc.As Perrdsospecificationno.Rdso/Spn/204/2011Ver.1.1Amdt.1Orlatestanti-Rodent&Anti-Oxidant And Non Flame Propagating Type In 6 Meters Straight Length And Of Size 120 Mm Outer Dia,& 103.5 Mminnerdia.(Themanufacturers,Suppliersmustproducevalidislicenseandshouldbecertified Under Iso 9000 And Shall Submit Copy Of Certificate). One Couple With Suitable Rubber O-Ring Should Be Supplied With Every 6 Mtr Of Pipe Length.(The Total Quantity Of Above Items Is Equal To No. Of Pipes Supplied.) Dwc Pipe Shall Be Marked At Every 1 Mtr Length In Such A Way That Manufacturers Name, Vendor Name And Year Of Manufacture Can Be Easily Identified. (Inspection Agency:-Consignee). , Supplyofapparatuscase/Locationboxfullasperrdsodrg.No.Rdso/S-11500Or Latest, With E Type Lock And Key Ward No. 42, . The Key And Handle Should Be Supplied At The Rate Of One No. Per Four Apparatus Cases. The E Type Key Lock Is As Per Rdso Spec. Irs;S-30/64 Or Latest, Rdso Drg. No.Sa 3376/M Or Latest And Key Is As Per Drg. No. 3377/M Or Latest. (Inspection Agency:- Consignee). , Supplyofapparatuscase/Locationboxhalfasperrdsodrg.No.Rdso/S-11507Or Latest, With E Type Lock And Key Ward No. 42, . The Key And Handle Should Be Supplied At The Rate Of One No. Per Four Apparatus Cases. The E Type Key Lock Is As Per Rdso Drg. No.Sa 3376/M Or Latest And Key Is As Per Drg. No. 3377/M Or Latest. Note: This Item Includes The Supply Of 2 Nos E Type Lock Fitted On Both Doors, Along With Two Keys. (Inspection Agency:-Consignee). , Supply Of Phenolic Laminated Sheet, Resin Bonded, Grade P3 In Standard Size Of 1220 X 1220 X 10 Mm As Per Spec. No Is 2036 Of 1995 Or Latest. Test Report Of Manufacture To Be Supplied. (Inspection Agency:-Consignee). , Supply Of Dc-Dc Converter As Per Spec No. Irs:S- 96/2000 Or With Latest Amendment / Specification Rating 24Vdc, 10A Suitable For (Make- Statcon). (Inspection Agency:-Rdso). , Supply Of 1 X 10 Sqmm (Red/Black/Green) Multi Strand Pvc Insulated Copper Flexible Power Wire, And Test Parameters As Per Rdso Specn.No.Irs:S-76/89(Amnd.3) Or Latest. Colour Of The Wire Which Is Required Will Be Specified By The Engineer Incharge. (Inspection Agency:-Consignee). , Supplyofdisconnectterminalblockforfourconductorswithscrewingcage/Clamp Type, Sliding Switch Disconnect, As Per Rdso Spec.No. Rdso/ Spn/189/2004 Ver. 3.0 Or Latest, For Each Conductor Size Up To 2.5 Sq. Mm, Equivalent Of M6 Terminals. Each Terminal Block Equipped With Two Markers,Ontopandbottom,Anendplate,Twoendclampsandadequatelengthofrailsforfitting Terminal Blocks. (Inspection Agency:-Rdso). , Supplyofaraterminalblock,Madeofpbt,Asperrdsospec.No.Irs:S-75/2006 (Rev.2) Or Latest And As Per Drawing. No. Sa- 23741A (Alt.-4) Or Latest.(Inspection Agency:-Rdso). , Supply Of Cartridge Fuse Block, Made Of Pbt, As Per Rdso Spec. No. Irs: S-75/2006 (Rev.2) Or Latest And As Per Drawing. No. Sa- 23748 (Alt.-4) Or Latest. (Inspection Agency:- Rdso). , Supply Of Non Deteriorating Type, Round Head Type, Low Voltage Cartridge Fuse As Per Spec No Irs: S-78/2006 With Latest Amendments, 10A Rating Capacity. (Inspection Agency:-Rdso). , Supplyandinstallationofearthelectrodeasperstandardpracticeand Asperncr Drawing No. S&T/Const/6.4/97. It Includes Supply Of Gi Pipe Of 3M Length. It Includes Connecting The Earth Electrode To The Equipments Which Are Required To Be Earthed Including Digging Of Earth Pit 3 Mtr Deep And Fixing Earth Electrode Pipe, Casting Of Cement Concrete Enclosure With Cover (Cover As Perncrdrawingno.S&T/Const/6.3/97).Itincludesinstallation Of7strandgiwiresasearthlead Wires, Supported On Ms Flat Size 5Mm X 40 Mm, Soldering And Nut Bolt Both, One End Of Both Earth Lead Wire And Ms Flat To Earth Electrode And Other End To Location Boxes, Block Equipments, Power Equipments,Cablesheath,Signalsetc.Aspersiterequirementandasperinstructionsgivenby Engineer Incharge. (Inspection Agency:- Consignee). , Supply & Installation Of Rfid Based Electronic Cable Route Marker For S&T/Power Cable, Which Can Be Buried At A Depth Range 1.5 Meter. Make -Stanlay/3M (Model:1420 Xid) Or Similar. This Item Includes The Gps Marking Of Rfid Marker With The Help Of Rfid Locator Or App Based System. (Inspection Agency:-Consignee). , Supplyofcableroutetracerwithgpsenable10watttransmitter,Rechargeable Batterypackandmaincharger,Directconnectionlead10meterextensioncablewithallother Accessories. Make- Radiodetection/Stanley/3M Or Better. (Inspection Agency:-Consignee). , Supply Of Portable Maintenance Service Terminal For Installation, Testing And Maintenance Of All Networking Parameters, As Per Technical Specification. Make-Hp/Dell Or Superior. (Inspection Agency:-Consignee). , Supply,Installation&Commissioningof40lphcapacitydistilledwaterplant(De Mineralizer Plant) As Per Following Specification: 1) Stage-1: Reverse Osmosis Based Pre-Treatment 2) Stage-2:Indianresinorsimilar3)Outputtreatedwaterperhourwillbe40ltrs(+/-10%)Andis Suitable For 2V 80Ah & 300Ah Batteries 4) Output Treated Water Per Hour To Be Between 6.0 To 8.0 Ph Value 5) 18 Pp Filters And 12 Carbon Filters For Free Filtration Are To Be Supplied Along With The System. Warranty Period Shall Be 12 Months Minimum From The Date Of Commissioning Or 18 Months From The Dateofsupplywhicheverisearlier,Materialshallbesuppliedalongwithawarrantycertificate. Installation Is To Be Done At Different Specified Locations In Jhansi Division. Accepted Make- Supertronics/Paramount(Nrdm40) Or Equivalent. (Inspection Agency:-Consignee). , Installation And Wiring Of Dc-Dc Converter For Item No. 7 Of Sch A .(Make- Statcon Or Similar) . , Laying Of S&T Cables Of Various Cores/ Pairs/ Quads In Trenches/ Gi Pipes/ Rcc Pipes/ Dwc Pipes Etc. As Per The Site Requirement And As Per Approved Cable Route Plan. This Also Includes Layingofcablesintrackcrossings&Roadcrossings.(Cableswillbemeggeredbeforeandafterits Laying By Contractor Under Supervision Of Railway Representative And He Will Submit The Meggering Report Of Each Testing). Length Of The Cable Laid Includes The Length Of The Cable Coiled For Termination Purposes. , Digging Of 1.20 Meter Deep And 0.3 Meter Wide Trenches Including Clearing Of Roots Of Trees And Bushes And Temporary Obstruction On The Selected Route And Cable Route Plan. It Includes Covering Of Cable Laid In Trench By Loose Soil For A Layer Of 50 Mm Thickness Approximately. Note:- In Case Where Digging Of Trench Up To 1.20 Meter Depth And 0.3 Meter Width Is Not Possible Or Bigger Sizetrenchisrequiredtolaymorecablesorloosesoil/Muckisencountered,Thedepthcanbe Reduced/Increasedasperdirectionsoftheengineer-In-Chargeoftheworks,Thepaymentwillbe Decreased/Increased Proportionate To The Depth & Width Of Excavation Compared To 1.20 Meter Deep And 0.3 Meter Wide In All Type Of Soft Soils Including Soft Rock. , Digging Of 1.20 Meter Deep And 0.3- Meter -Wide Trenches Including Clearing Of Roots Of Treesandbushesandtemporaryobstructionontheselectedrouteandcablerouteplan.Itincludes Covering Of Cable Laid In Trench By Loose Soil For A Layer Of 50 Mm Thickness Approximately. Note: In Case Where Digging Of Trench Up To 1.20 Meter Depth And 0.3 Meter Width Is Not Possible Or Bigger Size Trench Is Required To Lay More Cables Or Rocky Soil Is Encountered, The Depth Can Be Reduced / Increased As Per Directions Of The Engineer-In-Charge Of The Works, The Payment Will Be Decreased/Increased Proportionate To The Depth & Width Of Excavation Compared To 1.20 Meter Deep And 0.3 Meter Wide In Rocky Soils. , Cross Trench For Identification Of The Route Of Existing Signaling And Telecom Cables. , Horizontal Direction Drilling (Hdd)/Trenchless Digging/Machine Drilling Without Damage To Surface Road /Track For Laying/Insertion Of Hdpe/Gi/Dwc Pipe. The Bore Shall Be Done At The Depth Of Minimum1400mmfromthegroundlevel.Thegroundlevelshallbeconsideredignoringthebank Heightofthebankoftheroad.Note:-Dwc/Hdpe/Gipipesupplyisnotcoveredunderthisitem. Contactor Shall Provide All Material Required For Work And Adequate Nos. Of Labours For Proper Laying Of Cables Into The Bore. Cable Shall Be Laid Cautiously So That It Should Not Get Damage Due To Rough Handling & Pressure On Cable. , Horizontal Boring/Manual Moling Without Damage To Surface Road /Track For Laying/Insertionofdwc/Gi/Hdpepipe.Theboreshallbedoneatthedepthofminimum1400mm From The Ground Level. The Ground Level Shall Be Considered Ignoring The Bank Height Of The Bank Of The Road. Note:- Dwc/Hdpe/Gi Pipe Supply Is Not Covered Under This Item. Contactor Shall Provide All Materialrequiredforworkandadequatenos.Oflaboursforproperlayingofcablesintothebore. Cable Shall Be Laid Cautiously So That It Should Not Get Damage Due To Rough Handling & Pressure On Cable. Payment Of Boring Shall Be Made Only After Dwc/Hdpe/Gi Pipe Is Laid In The Bore. , Cement Concrete Work For Miscellaneous, Unscheduled Items In Ratio 1:3:6 Of Cement, Coarse, Sand And Aggregate Item Includes Excavation, Ramming Of Cc By Using Vibrator, Curing And Plastering With Cement And Sand Mixture In Ratio1:4 (Aggregate Will Not Exceed Beyond 3.8Cm).The Aggregate Cement And Sand Will Be Supplied By Contractor. , Cutting Of All Types Of Platforms/Road Crossing And Trenching And Excavation To A Width Anddepthof300mmx300mm,Layingofdwc/Hdpe/Gipipeinthetrenchandrefillingand Concretingitafterwardsasperoriginalcondition.Inhardrockygroundarea,Cableswillbelaid Normally On Layer Of Soft Earth Of 0.05 Mtrs Thickness Previously Deposited At Bottom Of The Trench. The Cutting To Be Filled And Finished With Cement/Concrete, As Per The Rdso Drawing No. Sdo/ Cable Laying/008, Issued Vide Rdso Document No. Rdso/Si/G/2010 Version 1.1 Dated 04.02.2014 Or Latest. , Placingofdwc/Rccpipesalongwithcollarsintrenchesatplacesoftrackandroad Crossings, Platform Cuttings Etc. Also For Straight Cable Laying (Cable Laying Is Covered Separately). , Laying And Fixing Of Medium Class Gi Pipes 100 Mm Dia (4.5 Mm Thickness) As Per Is 1239 ( Part 1) 2004 Or Latest With Coupling On Culverts/Bridges, Perforated At A Distance Of 20 Cm Or Less With 10 Mm Dial Hole, Or At Any Other Locations As Decided By Site Engineer.The Gi Pipe Is To Be Filledwithchatteredcompound.Itincludessupplyofallmaterialrequiredforfixingarrangement. Contractor Will Also Supply Flexible/Corrugated Hdpe Pipe At The End Of Gi Pipe To Protect The Cables Fromsharpedgesandsuddenbends.Thelayingandfixingtobedoneasperrdsodrawingsno. Sdo/Cablelaying/011Andsdo/Cablelaying/012Issuedviderdsodocumentno.Rdso/Si/G/2010 Version 1.1 Dated 04.02.2014, Or Latest , Earthing Connection And Soldering Of Cable Armour. (Unit:Per Cable=Per Conductor) , Terminationofoutdoorcables(Maincables/Tailcables)At/Ara/Disconnecttype Terminalsprovidedinapparatuscases,Cableterminationrackinrelayroom,Stationbuilding, Generatorroometc.Theitemincludesdressingofcablesandwireswithdressingthreadsasper Standard Practice. All Material Required For This Item Will Be Supplied By Contractor. The Outdoor Cable Shallbeterminatedinrelayroom,Ipsroom,Asmroometc.Undersupervisionandinstructions Issued By Engr. Incharge Of The Work. , Fixingofara(M-6)Terminals/Screwlessconnectors/Modulardisconnectterminal Blocks And Fuse Blocks On Phenolic Laminated Sheets And Fixing By Stainless Steel/Brass Nuts & Bolts. This Includes Provision Of Two Additional Holes On The Board On Either Side For Cable Conductor Entry. Theworkshallbecarriedoutaperinstructionsofrailwayengineerincharge.(Supplyofallabove Materials Has Been Covered Separately). , Lettering And Numbering Of All S&T Gears Like Signals, Loc. Boxes, Pt. Machines, Tljbs, Block Joints Etc. Each Item To Be Taken As One Unit. , Cable Insertion In Old Locations /Station Relay Room /Cable Pit Etc As Per Site Engineer And Filling With Sand And Plastering The Same. Note: All The Sundry Material Except That To Be Supplied By Railways Will Be Supplied By The Contractor. , Drawingofwiringcircuitina-3Sizesheetinautocad.(02Setsphotocopy&01Set Tracing With Soft Copy) . , Preparation & Submission Of Cable Route Plan Of Main & Tail Cables , Cable Cordage Plan, Locationparticulars,Ctrackparticulars,Meggeringreport,Earthresistanceparticulars,Traction Bonding Diagram And Any Other Drawing / Particulars Required In Auto Cad In Minimum A3 Size Each Sheetshouldhaveablockforsignatureofrailwayofficialsaswellasblockforsignaturethefirm, Where Signature Of Shall Be Put Up By The Authorized Signatory Of The Firms. The Name Of The Work As Begivenbytherailwayshallwrittenoneverysheetundertheworkcolumn.Onecompetesetof Tracings And Four Sets Of Copies Of Complete Above Detailed Particulars / Drawing Along With One Cd To Be Supplied By The Contractor In Thick Plastic Folders. , Development And Preparation Of Sip, Swrd/Gwrd/Swr Etc Based On Existing Sip/Esp.(For Station/Lc Upto 4 Lines) [Job=Per Stn/Lc , Excavation,Casting,Curingoffoundationandinstallationanderectionofapparatus Case Full (Apparatus Case Foundation As Per Ncr Latest Practice) With Contractors Own Frame, Cement And Other Material In The Ra Tio 1:3:6. E Type Lock To Be Supplied And Installed With Apparatus Case. This Includes Filling Of Location Foundations With River Bed Sand And Plastering On Top With A Mixture Of 1:4 Of Cement And Sand. It Covers Fixing Of Lamp Holder, Switch And Lamp Etc. In Apparatus Case. , Excavation,Casting,Curingoffoundationandinstallationanderectionofapparatus Case Half (Apparatus Case Foundation As Per Ncr Latest Practice) With Contractors Own Frame, Cement And Other Material In The Ra Tio 1:3:6.E Type Lock To Be Supplied And Installed With Apparatus Case. This Includes Filling Of Location Foundations With River Bed Sand And Plastering On Top With A Mixture Of 1:4 Of Cement And Sand. It Covers Fixing Of Lamp Holder, Switch And Lamp Etc. In Apparatus Case. , Fabrication And Fixing Of Phenolic Laminated Sheet Of Grade P3, Minimum 10 Mm Thick, Asperapparatuscasediagram/Plan,Inlocationboxbyprovidingallfixtureslikeara/Disconnect Terminals, Fuse Blocks, Fuses, Relays On Square Bars Etc. Including Fixing Of Pvc Coated String Rods At The Back Side For Cable Support With Contractors Own Material Like Iron Angle, Nuts, Bolts Etc. The Iron Angle For Fixing Shall Be Minimum 3 Mm Thick. This Also Includes Fixing Of Teak Wood Shelf Minimum 25 Mmthickforholdingtrackcircuitequipments.Theworkshallbedoneasperinstructionsofrly Engineer At Site. (Apparatus Case Full) , Fabrication And Fixing Of Phenolic Laminated Sheet Of Grade P3, Minimum 10 Mm Thick, Asperapparatuscasediagram/Plan,Inlocationboxbyprovidingallfixtureslikeara/Disconnect Terminals, Fuse Blocks, Fuses, Relays On Square Bars Etc. Including Fixing Of Pvc Coated String Rods At The Back Side For Cable Support With Contractors Own Material Like Iron Angle, Nuts, Bolts Etc. The Iron Angle For Fixing Shall Be Minimum 3 Mm Thick. This Also Includes Fixing Of Teak Wood Shelf Minimum 25 Mmthickforholdingtrackcircuitequipments.Theworkshallbedoneasperinstructionsofrly Engineer At Site. (Apparatus Case Half) , Paintingoftwocoatsofenamelpaintoveronecoatofredoxideprimerafter Scrappingandcleaningofthesurface.Painttobeofreputedmakeasian/Dulux/Bergerorsimilar. App. Cases Inside And Outside To Be Done By Silver Colour. (Apparatus Case Full) , Paintingoftwocoatsofenamelpaintoveronecoatofredoxideprimerafter Scrappingandcleaningofthesurface.Painttobeofreputedmakeasian/Dulux/Bergerorsimilar. Apparatus Cases Inside And Outside To Be Done By Silver Colour. (Apparatus Case Half)
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Uttar Pradesh View Result →
16.
Power #9336524 Technical Bid
RATE CONTRACT FOR UPKEEP / MAINTENANCE OF EXISTING 33/11 kV RECEIVING STATIONS ALONG WITH THEIR 33 kV LINES AND FABRICATION & HANDLING OF MATERIAL OF DIVISIONAL STORE UNDER THE JURISDICTION OF SUB-TRANSMISSION DIVISION-I, JPDCL, JAMMU FOR THE YEAR2025-26- 1 Erection of 16 mtr long Steel Tubular Pole with planting depth of 1/6 th of the height of the pole including digging of pits, disposal of extra earth, collection of boulders and filling back. 2 Erection of 13 mtr long Steel Tubular Pole with planting depth of 1/6 th of the height of the pole including digging of pits, disposal of extra earth, collection of boulders and filling back. 3 Erection of 11 mtr long Steel Tubular Pole with planting depth of 1/6 th of the height of the pole including digging of pits, disposal of extra earth, collection of boulders and filling back. 4 Erection of 9 mtr long Steel Tubular Pole with planting depth of 1/6 th of the height of the pole including digging of pits, disposal of extra earth, collection of boulders and filling back. 5 Erection of 13 mtr long PCC Pole with planting depth of 1/6 th of the height of the pole including digging of pits, disposal of extra earth, collection of boulders and filling back. 6 Erection of 11 mtr long PCC Pole with planting depth of 1/6 th of the height of the pole including digging of pits, disposal of extra earth, collection of boulders and filling back. 7 Erection of 9 mtr long PCC Pole with planting depth of 1/6 th of the height of the pole including digging of pits, disposal of extra earth, collection of boulders and filling back. 8 Painting of 16 mtr long Steel Tubular Poleincluding fixtures with one coat of red-oxide and two coats of silver(aluminium) paint 9 Painting of 13 mtr long Steel Tubular Poleincluding fixtures with one coat of red-oxide and two coats of silver(aluminium) paint 10 Painting of 11 mtr long Steel Tubular Poleincluding fixtures with one coat of red-oxide and two coats of silver(aluminium) paint 11 Painting of 09 mtr long Steel Tubular Poleincluding fixtures with one coat of red-oxide and two coats of silver(aluminium) paint 12 Cement Bottoming (U/G,A/G) in 1:3:6 mix including excavation and form work, (16/13/11/9 Mtr Long Poles (Complete Job) 13 Fixing of Galvanisedspiral Earthing of SWG No. 8,G.I wire of 115 turns confirming to REC-J1 construction standard, (J1) 14 Fixing of 66/33KV Galvanised Guy Set (Guy wire, Guy Rods, Turn Buckle plate ,Guy Insulators) confirming to IS 2141 / 1979 or the latest version thereof including digging of pits & refilling 15 Collection of Snapped ACSR Cond. and Re-stringing, tensioning , binding of ACSR Conductor, (100mm2 ACSR Conductor) 16 Collection of Snapped ACSR Cond. and Re-stringing, tensioning , binding of ACSR Conductor, (150mm2 ACSR Conductor) 17 Collection of Snapped ACSR Cond. and Re-stringing, tensioning , binding of ACSR Conductor, (200mm2 ACSR Conductor) 18 Dismantling of Steel Tubular Pole including carriage up to dumping site, (16 mtr. Long ) up to distance of 50 mtr 19 Dismantling of Steel Tubular Pole including carriage up to dumping site, (13 mtr. Long ) up to distance of 50 mtr 20 Dismantling of Steel Tubular Pole including carriage up to dumping site, (11 mtr. Long )up to distance of 50 mtr 21 Dismantling of PCC Pole including carriage up to dumping site, (11 mtr. Long )up to distance of 50 mtr 22 Dismantling of Steel Tubular Pole including carriage up to dumping site, (9 mtr. Long )up to distance of 50 mtr 23 Dismantling of PCC Pole including carriage up to dumping site, (9 mtr. Long )up to distance of 50 mtr 24 Dismantling of Three/Four pole structure, opening of channels, crossarms, angles(Complete Job.) 25 Dismantling of Two pole structure, opening of channels, crossarms, angles (Complete Job.) 26 Straightening of tilted Steel Tubular Pole (16 mtr. Long ) 27 Straightening of tilted Steel Tubular Pole (13 mtr. Long ) 28 Straighteningof tilted Steel Tubular Pole(11 mtr. Long ) 29 Straighteningof tilted PCC Pole(11 mtr. Long ) 30 Straighteningof tilted Steel Tubular Pole(9 mtr. Long ) 31 Straighteningof tilted PCC Pole(9 mtr. Long ) 32 Unloading of Steel Tubular Pole including carriage up to dumping site, (16 mtr. Long )up to distance of 50 mtr 33 Unloading of Steel Tubular Pole including carriage up to dumping site, (13 mtr. Long )up to distance of 50 mtr 34 Unloading of Steel Tubular Pole including carriage up to dumping site, (11 mtr. Long ) 35 Unloading of Steel Tubular Pole including carriage up to dumping site, (9 mtr. Long ) up to distance of 50 mtr 36 Loading of Steel Tubular Poles including carriage up to dumping site, (16 mtr. Long ) 37 Loading of Steel Tubular Poles including carriage up to dumping site, (13 mtr. Long ) 38 Loading of Steel Tubular Poles including carriage up to dumping site, (11 mtr. Long ) 39 Loading of Steel Tubular Poles including carriage up to dumping site, (9 mtr. Long ) 40 Extra carriage from dumping site, (16 mtr. Long )up to site of work Its 100 mtr 41 Extra carriage from dumping site, (13 mtr. Long )up to site of work Ist 100 mtr 42 Extra carriage from dumping site, (11 mtr. Long )up to site of work Ist 100 mtr 43 Extra carriage from dumping site, (9 mtr. Long )up to site of work Ist 100 mtr 44 Extra carriage of 9 Mtr PCC Pole beyond 100mtrs for every 50Mtr or part thereof in plain areas 45 Extra carriage of 11 Mtr PCC Polebeyond 100mtrs for every 50Mtr or part thereof in plain areas 46 Extra carriage of 9 Mtr PCC Pole beyond 100mtrs for every 50Mtr or part thereof in semi hillyareas 47 Extra carriage of 11 Mtr PCC Pole beyond 100mtrs for every 50Mtr or part thereof in semi hilly areas 48 Unloading of Steel of Sorts , (Steel) 49 Loading of Steel of Sorts , (Steel) 50 Unloadingof Conductor Reels, (100mm²/150mm²/200mm² ACSR Conductor)at site 51 Loadingof Conductor Reels, (100mm²/150mm²/200mm² ACSR Conductor) at site 52 Fixing of 33 kVDiscInsulator (70 KN)2008 standards, (Porcelain ) 53 Fixing of 33 kV Disc fitting (70 KN) 2008 standards, (Polymer) 54 Fixing of 33 kV Insulators (10 KN) standards, (Porcelain ) 55 Fixing of33 kV Pin Insulators (10 KN) suitable for 100/150/200mm² ACSR Conductor. 56 Replacement/Fixing of 33 kVTension fittings (Socket & Ball type or T&C Type) for ACSR 57 Replacement/Fixing of 33 kV Tension fittings (Socket & Ball type or T&C Type) for ACSR 150m² 58 Replacement/Fixing of 33 kVTension fittings (Socket & Ball type or T&C Type) for ACSR 200m² 59 Straighteningof X-arms of different sizes (100x50x50x6 mm channel Iron,50x50x6mm Angle Iron ) duly painted with one coat of red-oxide and two coats of silver paint fixing with different sizes and sorts of nuts,bolts and washers, (Channel Iron X-arms, Angle Iron-X-arms, Pole Tops) 60 Straighteningof angle ironof different sizes (65x65x6 mm channel Iron,50x50x6mm Angle Iron 61 Repair and re-erection of Cradle for guard netting with GI wire 8 No including wire binding, cutting /bending of GI Wireas per REC standards 62 Branch cutting of 33 kV lines 63 Removing of wild climbers/vegetation around 33 kv Poles 64 Removing of wild climbers/vegetation around 33 kV Tower 65 Removing of wild climbers from top of 33 kV Lines. 66 Removing of wild climbers from Peak, cage, cross arm of 33 kV old tower Line 67 Patrolling of 33 kV Line(Routine/Under fault) 68 Tightening of loose guys 69 Dismantling & re-erection of damaged guys including digging of pit & refilling the same 70 Replacement of damaged Disc insulator in tension string 71 Replacement of cross arms of sizes 100x50x6 72 Replacement of angle iron of sizes (65x65x6, 50x50x6) 73 Replacement of Pin insulator on Four/Three/Double Pole Structure 74 Replacement of Pin insulator on Single Pole Structure 75 Replacement of Worn-out/Damaged Jumper of 33 kV Towerlines 76 Replacement of Disc Insulator, Suspension Fitting of 633 kV Towerlines 77 Replacement of worn-out/Loose/Damaged Jumper of 33 kV lines (sets of3 Nos) 78 Local earthing of 33 kV Lines by way of using discharge/earth rods at faulty site to avoid accident due to any induction while working on Line. 79 Tightening / restringing of loose ACSR Dog 100 mm2 80 Tightening / restringing of loose ACSR Wolf 150 mm2 81 Tightening / restringing of loose ACSR Panther200 mm2 82 Dismantling & Re-erection of ACSR Dog 100mm2 including collection of dismantled conductor , making of small bundles and its carriage 83 Dismantling & Re-erection of ACSR Wolf 150mm2 including collection of dismantled conductor , making of small bundles and its carriage 84 Dismantling & Re-erection of ACSR panther 200mm2 including collection of dismantled conductor , making of small bundles and its carriage 85 Dismantling of stay sets complete 86 33 KV VCB Repairs & Renovationby way of a) Setting of Mechanical Assembly / Replacement of damaged spring / Repair of locking & charging system 87 b) Replacement of Tripping Coil/Closing coil 88 c) Replacement of Damaged Vacuum Interrupter 89 d) Replacement ofBushing including Clamps 90 33 kV C&R Panel: Replacement of different equipmentsa) Ammeter, Volt Meter Indication , Lamps, Fuses, Trip Close Switch ,Selector SwitchIdentification of Panel Wiring Faults & its rectification 91 b) Replacement of Different Relays - MITNumerical Relay / Electro-mechanical relay / Master Trip Relay/ Differential Relay/Auxiliary Relay etc. 92 Installation, Testing, commissioning of 66-33 kV Control Relay Panels (Complete Job) 93 Complete testing of Relays Setting of Testing Kit, Interconnection between various points of panel with respect tosecondary injection key on various current taps, recording the observation thereof. All modifications necessary to achieve desired results. 94 Control Cable Replacement of damagedControl Cables of all typesincluding binding with PVC Belts/ Binding Wire, Peeling of insulation and fixing of proper size thimble connecting the cable after identification of each core to both ends i.e. Panel to CTs / panel toPTs /panel to Breaker and Making functional of 33 KV Outdoor Breakers, Protection , Alarms, Annunciation (complete Job) 95 Upkeep of earthing of aux. transformer 96 Upkeep of earthing of Power transformer 97 Upkeep of earthing of 33/11 kV LA 98 Providing of extra earthing for improvement purpose (complete job) 99 Upkeep of earth mat of out door yard 100 Replacement of damaged earth mesh in Sub-Station as per approved Map & Design. 101 Excavation of trenches of 0.6 Mtr Depth and 2.0 Mtr wide mtr in normal soil / hard soil 102 Repairing / Laying of MS Flat and MS Rod in deep excavated trench and welding of MS Flat & MS Rod with Mesh. 103 Repairing of Earthing with Spikes of MS Rod 20mm, 3 Mtr in Length as per REC Drawing 104 33/11 KV Power Transformera) Opening of Transformer Tank Top Cover to prevent oil leakage from top(if required to facilitate maintenance of transformer after removing the required accessories), ,Draining/ Re-Filling of required Oil, Change of gaskets of valves/ radiators/ Buchholzs relay radiators valves of power transformer of capacity: 3.15 MVA to 10 MVA 105 b) Replacement of silica gel 106 c) General Inspection by through inspection of each individual parts, Ratio test by applying voltage on HV Side and measuring LV Voltage on various Tap Positions, checking of Buchholz relay, Surge relay conservator, sensors, measurement of 1R-Value dialectic strength of oil, cleaning of Power Transformer etc 107 d) Replacement of any one of the following i.e. temperature indicators, gas operated Buchholzs relay, oil temperature indicator, winding temperature indicator etc 108 e) Preventing of leakage by changing main gaskets after removing the old gasket, Replacement of HV/LV Busing & Bush Rod,Ring and Rubber Washers (complete job to prevent leakages) 109 f) Cleaning of Scale deposited over the body and radiators of the power transformer with thinner/ detergent and de-rusting in perfect manner.(routine work) 110 g) Cleaning of LV/HV bushings of Power Transformer(routine work) 111 h) Replacement of Bus Bars ofPower Transformer 112 i) Replacement of LV/HV clamps of Power Transformer 113 Oil Topping of Power Transformer 10 MVA 114 Oil Topping of Power Transformer 4 MVA to 6.3 MVA 115 Oil Topping of Power Transformer 3.15 MVA 116 Recording of IR values of transformers 117 Installation, Testing and Commissing of Power Transformer 66-33/11 KV Installation of LV/HV Bus Bars with proper care, of transformer for any leakagecommissioning of Power of Transformers by applying low voltageapproximately equal to impedance voltage on HV Side and short circuiting the LV terminals, Energizing the transformer by applying required primary voltage to it & keeping the transformer on no load to observe the behaviour of transformer, setting on 25% of the load on the transformer for a period of at test 6 hours and observation of oil including temperature, increase the transformer is fully loaded and topping of oil.a) 10 MVA 118 b) 6.3 MVA 119 c) upto 5 MVA 120 Checking and tightening of Jumpers, Droppers in 66/33 KV Outdoor Yard 121 Replacement of T/PG clamps 122 Replacement of Disc insulators including its hardware. 123 33 KV LA & 11 KV Stn. Type LAReplacement of 66 KV,33 KV & 11 KV Lightening Arrestor including jumpering and earth connecting in all respect. a) 66 KV LA 124 b) 33 KV LA 125 b) 11 KV LA 126 Separate pipe Earthing / G.I Rod earthingas per REC Drawing J.2 127 Replacement of pipe earthing / Rod earthing with new one 128 Installation, testing and Commissioning, replacement of 66 KV Isolators 129 Installation, testing and Commissioning,replacement of 33 KV Isolators 130 Replacement of11 KV Isolators 131 Repair & Renovationof 66/33 KV and 11 KV isolators including setting right its alignment for proper operation, lubrication/greasing of jaws, bearings operatings handle etc(complete job) 132 Replacement of worn-out/heated Pad clamp/Isolator clamps of 66/33/11 kV Isolator by way of dismantling. Drilling of holes on new and fixing (complete job) 133 Repair & Renovationof Isolator Jaws 66/33 KV and 11 KV isolators.(complete job) 134 Replacement of post insulator / tendon pipes/ operating box by way of dimentalling, necessary fabrication where ever required for proper operation of 66/33/11 kv Isolators. 135 33 KV CTsInstallation, testing and Commissioning of 33 kV CTs ( of all ratios )Complete Job 136 33 KV CTsRepairs & Renovation of 33 KV CTs by way of replacing shorting strips, connecting rod, transformer oil, damaged insulator (CTs of all ratios) 137 Replacement of 33 KV Outdoor Type CT of different ratio and dismantling of damaged CT(CTs of all ratios) 138 Oil Topping of 66/33 kV CT & PT by way of opening of top cover and refixing with new gaskets if necessary and preventing of oil leakages if any.(complete job) 139 66-33 kV PTsInstallation, testing and Commissioning of 66-33 kV PTs (complete job) 140 66 kV PTsReplacement of 66 KV Outdoor Type PT and dismantling of damaged PT, dragging to installation/loading site, lifting from ground to steel structure. 141 33 kV PTsReplacement of 66 KV Outdoor Type PT and dismantling of damaged PT, dragging to installation/loading site, lifting from ground to steel structure 142 Cleaning of porcelain bushing, tightening ofPT/CT clamps, derusting & painting of body of 33 kV PTs & CTs 143 Tightening of nuts & bolts, replacement of oval thread bolts, chipping by way of welding to the bolts after tightening in a single bay 144 Painting with mix red oxide paint two coats of approved make on steel works after cleaning with wire brush/ sand paper 145 Painting of steel structure erected in outdoor yard with aluminium paint two coats with approved brand andfixture to given an even surface 146 Battery Banka) Repair & maintenance of battery set including maintaining specific gravity, electrolyte level, cleaning, checking, tightening of battery terminals in all respects it includes measuring voltage of each battery. 147 b) Tightening of all nut and bolts, replacement of damaged battery cells 148 c) Installation, testing and Commissioning of Battery Bank (complete Job) 149 Battery ChargerRepair/Renovation battery charger for proper functioning by way of replacement of rectifier unit, Ammeter, Voltmeter, MCB,Cooling fan, LED indications, buzzer alarms for OV/UV etc (Complete Job) 150 Repair and maintenance of DC Board, identification of fault in respect of cableand its replacement, replacement of damaged MCCB, Kit Kat, Bus Bar & other allied job. 151 Repair and maintenance of AC Board, identification of fault in respect of cableand its replacement, replacement of damaged MCCB, Kit Kat, Bus Bar & other allied job. 152 Installation, testing and Commissioning of Battery Charger (complete Job) 153 Deweeding of vegetation in outdoor yardRemoving of stone metal, deweeding of unwanted vegetation, spreading of stone metal collected earlier for removal of vegetation, levelling the area with existing stone metal 154 Providing of additional stone metal and its carriage and laying in outdoor yard, this including breaking of stones complete job. 155 Cleaning of Control Room, removing dirt & dust from the panels, walls, cleaning of fixtures (for one bank) 156 Painting of internal/external walls and roof by approved brand of oil based distemper 157 Painting of door and window panels of control room by approved brand of paint 158 Repairs & Renovation of 11 KV VCB,by way of replacement of a) Grid-spout assembly 159 b)Replacement of damaged CTs of different ratio Testing the CT with the help of primary injection set fixing in pannel, fixing the secondary connection after assessing the load (complete job) 160 c)Thorough checking of control wiring circuits, replacement of damaged wire if any, replacement of terminal plates, tripping circuits, close/ trip switch, ammeter switch, replacement of voltmeter & ammeter . 161 d) Replacement of 11 KV damaged PT 162 e) Replacement of blown fuses, checking the PT terminal with respect of 11 KV bus bar complete job. 163 f) Replacement of Trip/Close coil 164 g) Replacement of Trivector meter on 11/33/66 kV Panels 165 Installation, testing and Commissioning , replacement of LT cabele 166 11 KV Power Cables / 33 KV Power cables/66 KV Power cablesa) Identification of damaged portion of cable, tracing of cable, remove cable from trench, carriage and laying of cable(complete job) including cleaning of cable trenches. 167 b) Replacement of damaged cable of sizes 168 Replacementof termination kits of different sizes, connecting the cable with panel and outgoing structures after crimping of lugs fixing with nuts and bolts, checking of earth point, connecting the earthing point of cable with existing earthing system a) 11 KV Indoor Termination Kit (1-Phase/ 3 phase) 169 b) 11 KV Outdoor Termination Kit (1-Phase/ 3 phase) 170 c) 33 KV Indoor Termination Kit (Single Phase) 171 d) 33 KV Outdoor Termination Kit (Three Phase) 172 e) 33 KV Indoor Termination Kit (Three Phase) 173 f) 33 KV Outdoor Termination Kit (Single Phase) 174 Improvement of earthing system in control room by way of replacement of earthing risers from earthing point to panel / checking of all welding points/ re-welding of lose connection, laying of fresh / additional earth-mat strip to improve the existing earthing system (Complete one Panel set) 175 Checking of IR values 176 De-watering of receiving station to avoid water logging. 177 Repairing of electrical circuits for improvement of control room immunination, power points etc (Complete Job) 178 Installation, Testing, commissiing for replacement of Aux. Transformer at receiving station 179 On site repairing of aux transformer for missing phase, LT strip, LT bush rod, LT bush cup, HT bush rod etc (Complete job) 180 Transport charges for carriage of T&P, men & material on urgent basis during power breakdown and restoration of system. (auto carrier) aditional 1km @ 90/per km 181 Replacement of out door yard lights including wiring system and fixing oflamps on fixtures. 182 Marking of equipments, sign boards by way of painting/fixing of PVC plates for demarcation of different equipment to avoid mishandling. 183 Replacement/repair/fixing of ceiling fans at Receiving station. 184 Replacement/repair/fixing of cooling fans on radiators of power transformer to avoid heating. 185 Flash in 66KV,33 KV & 11 KV Panels due to overloading moisture, Cleaning of carbonized panel by petrol / cotton cloth, replacement of damaged / worn-out lugs, post insulator, Bakelite sheet, arcing chamber panel heaters etc. 186 Repair of plaster of thickness 12 mm to 20 mm in patches of areas 2.5 sqm meters and under including cutting the patch in proper shape and preparing and plastering the surface of the walls complete incl. disposal of rubbish to the dumping ground within 50 M leada) with Cement mortar 1:4 (1 cement : 4 fine / coarse sand) 187 Cutting of large tree branches falling over 33/11 lines and coming into the corridor to avoid damages/ faults/conductor snapping. 188 Cleaning of cable duct, removing of duct covers and placing back after cleaning the duct including disposal of rubbish up to 50 Mtr lead 189 Replacing sand store slabs in roofing, laid incement mortar 1:4 (1 cement : 4 coarse sand) including necessary repairs and cement painting with same mortar complete, including disposal of rubbish to dumping ground within 50 Meters of lead 190 Dismantling doors, windows and clerestory windows (steel or wood) shutter including chow khats, holdfast etc. Complete and stacking with 50 Mtr lead 191 Providing and fixing T-iron frames for doors, windows and ventilators of mild steel T-sections, joints mitred and welded, including fixing of necessary but hinges and screws and applying a priming coat of approved steel primer (CC 1:3:6) 192 Demolishing cement concrete manually / by mechanical means including disposal of material within 50 Mtr 193 Cement concrete 1:2:4 (1 Cement : 2 Coarse Sand : 4 graded Stone aggregate)62 mm thick 194 Roof top treatment to prevent water leakage of control room 195 Repairing of receiving station mesh fencing / Chain link mesh fencing height upto 8ft 196 Watering of earth pits 197 Cleaning/washing of solar panels & batteries 198 Cleaning of ACDC,DBDC Board, RTCC, Charger, Battery Bank, Solar batteries, other alike small equipments (complete Job) 199 Cleaning of 33 kV CRP using vacuum cleaner from inside with proper care, from outside with thinner/varnish and making 33 kV CRP Vermic Proof. 200 Cleaning of 11 kV Panel using vacuum cleaner from inside with proper care, from outside with thinner/varnish and making it Vermic Proof to avoid rodent faults. 201 New 33 KV Line Fabrication , erection and painting of 15 Mtr long 33 KV Self supporting tower structure for crossing of road 202 Laying of foundation for 33 KV self supporting Tower Structure 15 Mrs. long including setting of stubs complete job 203 Erection of Channel cross arm of size 100X50X 6mm ,10 feet long and above including fixing of MS flat iron clamps with required size of bolts including punching of bolts complete 204 Erection of Channel cross arm of size 100X50X 6mm up to 09 feet long including fixing of ms flat clamps with required size of bolts including punching of bolts complete 205 Erection of Angle Iron Braces of size 65X65X6 mm,fixing with double clamp of MS Flat including punching of bolts of Ist level to level 3rd in cross section typeabove up to 14longcomplete 206 Erection of Angle Iron Braces of size 65X65X6 mm along with belts of same size ,fixing with double clamp of MS Flat including punching of bolts of Ist level to level 3rd in cross section type 6 and above upto 10longcomplete 207 Erection of Angle Iron belts of size 50X50X 6 mm along with belts of same size ,fixing with double clamp of MS Flat including punching of bolts of Ist level to level 3rd in cross section type upto 10 long 208 Erection of Angle Ironof size 65X65X6 mmfixing with double clamp of MS Flat including punching of bolts of Ist level to level 3rd in crossection typeabove11 long complete for guardnetting. 209 Flat iron ties 50x6 mm size 1 feet long along with fixing with cross arms 210 Erection of 33 KV Disc insulator (polymer type )with tension fittings including punching of locking pinscomplete 211 Erection of 33 KV Pin insulator with pins3 nos on top of cross arm including fixing of MS Flat Ties to rest it on , punching of base bolt /locking pin complete 212 Erection of Guy rodincluding digging of pit , Disposal of excavated soil ,refilling of excavated pits in layers of stone boulders and fine soil including fixing , adjusting properly Turn Buckle, Anchor Plate and staining screw complete 213 Carriage at site , un-bundling , Laying and stringing of ACSR DOG Conductor including making of small bundles of conductor as per site requirement, cutting in required span lengths complete (AS PER REC STANDARD) 214 Erection of anti climbing Devices at ST pole along with fixing /cutting /bending of Barbed wire, fixing with clamps 215 Erection of Danger plates 216 Route /temp path clearance by way of cleaning bushes and vegetation & making temp. pathcutting & filling for carriage of line material ( 400 mx1mx0.2m)= 80 cum 217 Watch and ward of the material and T&P round the clock i.e. 3 shifts, Rate of 1 Lab for 1 Shift 218 Route clearance for corridor of 5 m 219 Installation, testing and Commissioningof 3.15 MVA , 33/11KV Power Transformer (new work) 220 Installation, testing and Commissioning of 5 MVA& 6.3 MVA , 33/11 KV Power Transformer 221 Installation, testing and Commissioningof 10 MVA , 33/11KV Power Transformer 222 Installation, testing and Commissioning of 11kV Panel Borad with VCB Incomer(one no.) 223 Installation, testing and Commissioning of 11kV Panel Borad with VCB outgoing(one no.) 224 Setting of stubs with templates after positioning and leveling of templates excluding cost of foundations 225 Handling and Fabrication of Material in Divisional Store, Fabrication of Angle iron braces/belts /guard netting angles,fencing posts etc from angle iron of sizes 226 Fabrication of guy rods complete including turn buckle, staining screw, anchor plate, thereading of guys and staining screw 227 Fabrication of channel cross arms of sorts from MS channel of sizes , Making holes as per requirement,Punching of members and numbering on each member,Grinding of sharp edges and uneven surface of memebers and painting of members with red oxide paint. 228 Fabrication of ties, clampsfrom MS flat ( suitable for 9 mts, 11mts, and 13mts poles) 229 Fabrication of earthing plates , cable duct coversfrom MS plate as per REC drawings 230 Fabrication of earthing spikes from MS Tor steel of sorts as per REC drawings 231 Fabrication of ST poles by way of drilling of extra holes 232 Fabrication of foundation boltsfrom MS Tor steel of sorts including threading as per REC drawings 233 Fabrication of earthing pipe from GI pipe and welding of earthing plateas per REC drawings 234 Fabrication of column structures, beam structure, isolator structures,LA ,CT,PT and PI Structures as per REC drawings 235 Shifting of channel/Angle /Flat iron at and average distance of 50mtr from unloading site to site of stacking and stacked properly. 236 Shifting of channel/Angle /Flat iron/fabricated material at and average distance of 50mtr for making space for other store material and its stacking . 237 Unloading of ST poles 9mtr in divisional store 238 Unloading of ST poles 11mtrin divisional store 239 Unloading of ST poles 13mtrin divisional store 240 Unloading of ST poles 16mtrin divisional store 241 Unloading of PCC Poles 9/8 mtr . in divisional store 242 Unloading of PCC Poles 11 mtrin divisional store 243 Unloading of PCC Poles 13 mtr in divisional store 244 Dragging/shifting of PCC/ST Pole at and average istance upto 50 mtr for stacking to accesible place for loading/unloading purpose and its satacking 245 Unloading of ACSR Conductor dogin divisional store 246 Unloading of ACSR Conductor wolfin divisional store 247 Unloading of ACSR Conductor pantherin divisional store 248 Shifting of Old/New ACSR Conductor at and average distance of 50mtr for unloading site to site of stacking and stacked properlyand also for making space for other store material and its stacking .. 249 Unloading of 11KV VCB pannels (1+3) 250 Unloading of 11KV VCB pannels (1+4) . 251 Unloading of 11KV VCB pannels (1+5) . 252 Unloading of 11KV VCB pannels OK/Damage(1no) . 253 Unloading ofAC Board/DC Board/Battery bank/ Battery charger 254 Unloading of 33 VCB /C&R Pannel . 255 Shifting/ draggingof 11/33/66kv panel at an average distance of 50mtr for making space for other store material and its stacking also for making space for other store material and its stacking . 256 Unloading of XLPE Cable 120/185 mm² . 257 Unloading of XLPE Cable 240/300 mm² . 258 Unloading of XLPE Cable 400/630 mm² . 259 Shifting of XLPE Cable all sizes at an average distance of 50mtr from unloading site to site of stacking and stacked properly also for making space for other store material and its stacking ... 260 Unloading of 66/33/11 KV Cable kits of different sizes 261 Shifting of 66/33/11 Cable kits of all sizes at an average distance of 50mtr from unloading site to site of stacking and stacked properly also for making space for other store material and its stacking ... 262 Unloading of Guy/GI wire/Barbed wire including carriage towards stacking site and stacked porperly. 263 Unloading of Power Transformer 3.15/4 MVA New/damage . 264 Unloading of Power Transformer 5/6.3MVA New/damage . 265 Unloading of Power Transformer 10 MVA New/damage . 266 Unloading of 11KV New/damage DistributionTransformer. 267 Dragging of 3.15/4 MVA New/damage Transformer at an average distance upto 50 mtr for stacking to accesible place for loading/unloading purpose and its satacking 268 Dragging of 5/6.3 MVA New/damageTransformer at an average distance upto 50 mtr for stacking to accesible place for loading/unloading purpose and its satacking 269 Dragging of 10 MVA New/damage Transformer at an average distance upto 50 mtr for stacking to accesible place for loading/unloading purpose and its satacking 270 Dragging of 11kv Transformer at an average distance upto 50 mtr for stacking to accesible place for loading/unloading purpose and its satacking 271 Unloading ofTransformer oil Barrels. 272 Dragging ofTransformer oil old/ new barrel at an average distance upto 50 mtr for stacking to accesible place for loading/unloading purpose and its satacking also for making space for other store material and its stacking .. 273 Unloading ofMS Angle, MS Channel, MS flate ,tar steel 274 Unloading of hardware items such as nuts and bolts , clamps of sorts, washers,welding rods,old sarees,chain link mesh,pipe etc . 275 Shifting ofhardware items such as nuts and bolts , clamps of sorts, washers,welding rods,old sarees,chain link mesh,pipe etc at an average distance of 50mtr for making space for other store material and its stacking . 276 Unloading of 33/11 KV Dics insulators. 277 Unloading of 33 KV Dics fittings 278 Shiftingof 33/11KV disc insulator at an average distance upto 50 mtr for stacking to accesible place for loading/unloading purpose and its satackingalso for making space for other store material and its stacking .. . 279 Unloading of 33/11 KV Pin insulators/Guy insulator /G.I Pin. 280 Shiftingof 33/11KV pin insulator /guy/G.I Pinsat an average distance upto 50 mtr for stacking to accesible place for loading/unloading purpose and also for making space for other store material and its stacking. 281 Unloading of Cement. 282 Shiftingofcement/cement block at an average distance upto 50 mtr for stacking to accesible place for loading/unloading purpose and also for making space for other store material and its stacking ... 283 Unloading of 33 KV CT/PTUnit . 284 Shifting of 33 KV CT/PT at an average distance of 50mtr for making space for other store material and its stacking . 285 Unloading of 11 KV CT/PTUnit includingcarriage towards stacking site and stacked porperly. 286 Shiftingof 11 KV CT/PTat an average distance upto 50 mtr for stacking to accesible place for loading/unloading purpose and also for making space for other store material and its stacking .. 287 Unloading of 33 KV Isolators. 288 Shiftingof 33KV Issolatorsat an average distance upto 50 mtr for stacking to accesible place for loading/unloading purpose and its satackingand also for making space for other store material and its stacking . . 289 Unloading of 33/66 KV LAs. 290 Shiftingof 33/66KV LAsat an average distance upto 50 mtr for stacking to accesible place for loading/unloading purpose and also for making space for other store material and its stacking . 291 Unloading of 11 KV LAs/GO/HG/issolator . 292 Shiftingof 11 KV LAs/GO/HG/issolator at an average distance upto 50 mtr for stacking to accesible place for loading/unloading purpose and also for making space for other store material and its stacking .. 293 Unloading of PVC Cable /Control cable of different sizeincludingcarriage towards stacking site and stacked porperly. 294 Unloading of AL Paint /Red oxide paint/ Black paintincludingcarriage towards stacking site and stacked porperly. 295 Unloading of T&P Items like Drilling machine,chainPully ,Pully lifting machine ,Hand drill machine,AL ladder,welding set,tool kit,crimping tooletc 296 Unloading of Testing equipments like Meggar, Earth resitivitytester , Oil testing machine,Search Light, Turn ratio meter , multimeter etc . 297 Unloading of Safetyequipments like Safety belts, Safety shoes, Fire Extinguisher,Hand gloves, Yard lights , LED Bulbs , Rubber mat , etc 298 Shiftingof T&P /Testing / Safetyequipments at an average distance upto 50 mtr for stacking to accesible place for loading/unloading purpose and also for making space for other store material and its stacking .. 299 Unloading of Filter plant heavy duty 300 Shiftingof Filter plantat an average distance upto 50 mtr for stacking to accesible place for loading/unloading purpose and also for making space for other store material and its stacking . 301 Loading of PCC Poles 9/8 mtr 302 Loading of PCC Poles 11 mtr 303 Loading of PCC Poles 13 mtr 304 Loading of ST poles 9mtr 305 Loading of ST poles 11mtr 306 Loading of ST poles 13mtr 307 Loading of ST poles 16mtr 308 Loading of ACSR Conductor dog 309 Loading of ACSR Conductor wolf 310 Loading of ACSR Conductor panther 311 Loading of Cement 312 Loading of 11 KV VCB 1+3 Pannels 313 Loading of 11 KV VCB 1+4 Pannels 314 Loading of 11 KV VCB 1+5 Pannels 315 Loading of 11 KV VCB 1 Pannel OK/Damage 316 Loading of AC Board/ DC Board/Battery charger /Battery bank 317 Loading of 33KV VCB 318 Loading of 33KV C&R Pannels 319 Loading of XLPE Cable 120/185 mm² 320 Loading of XLPE Cable 240/300mm² 321 Loading of XLPE Cable 400/630 mm² 322 Loading of Cable kits of different sizes 323 Loading of Guy/GI wire/Barber wire 324 Loading of Power Transformer 3.15/4.0 MVA 325 Loading of Power Transformer 5.0/6.3 MVA 326 Loading of Power Transformer 10 MVA 327 Loading of 11 KV DistributionTransformer 328 Loading of Transformer Oil barrels 329 Loading of MS Angle iron braces, MS channel cross arms, Guy rod, Earthing spikes, MS Flate 330 Loading of hardware items such as nuts and bolts, clamps of sorts,washers,welding rods,old sarees,chain link mesh,pipe 331 Loading of 33 /11KV Disc insulator 332 Loading of 33 KV Disc fitting 333 Loading of 33/11 KV Pin insulator /Guy insulator /G.I Pin 334 Loading of 33 KV isolator 335 Loading of 33 KV LA 336 Loading of 11KV Isolators 337 Loading of PVC Cable /Control cable of different size includingcarriage from stacked site. 338 Loading ofAL Paint /Red oxide paint/ Black paint 339 Loading ofFilter plant heavy duty 340 Carriageof Fabrication column structures, beam structure, isolator structures,LA ,CT,PT and PI Structures etc towards stacking site and stacked properly 341 Loading ofFabrication column structures, beam structure, isolator structures,LA ,CT,PT and PI Structures etcincludingcarriage from stacked site. 342 Loading of 33 KV CT/PT units 343 Loading of 11 KV CT/PT units 344 Loading of T&P Items like Drilling machine,chainPully ,Pully lifting machine, Hand drill machine,AL ladder,welding set,tool kit,crimping tooletc units 345 Loading of Testing equipments like Meggar, Earth resitivitytester , Oil testing machine,Search Light, Turn ratio meter , multimeter etc units 346 Loading of Safetyequipments like Safety belts, Safety shoes, Fire Extinguisher,Hand gloves, Yard lights , LED Bulbs , Rubber mat , etcunits 347 Shifting of allied materials for making space for porper stacking of material 348 Carriageof Fabrication material from fabrication site towardsstacking site and proper stacking of material. 349 Repair of store shed by way of replacement of damaged CGI sheets, repair of CGI sheets by way of welding, replacememt of hooks, nuts and bolts, tightening of nuts bolts and hooks and welding . 350 Collection andcarriage of T&P items to working site and back crriage of T&P after job 351 Sorting of material by way of weighing / measuring and inspection of material and then carriage from weighing / measuring and inspection site to site of fabrication 352 painting of store shed with red oxide/Al paint single coat 353 Checking/Measuring/ Inspection/Meggering ofXLPE Cable/Control cable by way of unreal and after work agian rereelingon drum 354 Checking/Measuring/ Inspection ofACSR Conductorby way of unreal and after work agian rereelingon drum 355 Complete testing/ispection of pannels including relay testing , interconnection,charging polarity etc during issue/receipt/verification. 356 Prototype errection of Gantry /Beam/CT/PT/Isolator sturcture 357 Dismentling of ACSR Dog Conductor 358 Dismentling of ACSR Wolf Conductor 359 Dismentling of ACSR Panther Conductor 360 Dismentling of 3.15 MVA, 33/11 KV Power Transformer including dismentling of Cables, Radietors, drainage of Oil and filling in empty Barrels 361 Dismentling of 6.3 MVA, 33/11 KV Power Transformer including dismentling of Cables, Radietors, drainage of Oil and filling in empty Barrels 362 Dismentling of 10 MVA, 33/11 KV Power Transformer including dismentling of Cables, Radietors, drainage of Oil and filling in empty Barrels 363 Dismentling of 11 KV Panel Board with VCB (Incommer) 364 Dismentling of 11 KV Panel Board with VCB (Outgoing) 365 Installation of SMPS & CMR on Smart Meters 366 Installation/Replacement of Smart Meters
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 32
Jammu And Kashmir View Result →
17.
Public Administrative Department #9286614 Technical Bid
Expression Of Interest For Preparing Estimate For Establishment Of Cctv Surveillance System At Various Areas Of Saoner City- 1 Establishment Of Cctv Surveillance System At Various Areas Of Saoner City 2 1. Supplying, Erecting, Testing & Commissioning Of 1000Va Line Interactive Ups.Power Rating: 1000Va / 600W, Voltage: 230 Vac ± 10% ( Battery Mode ) , Frequency Range: 50 / 60 Hz ± 1 Hz, Waveform ( Batt. Mode ) : Simulated Sinewave, Receptacle: India Socket X 4, Battery Type & Number: 12V / 7 Ah X 2, Recharge Time: 4 ~ 6 Hours To 90%, Cold Start: Yes, Indicator: Led, Communication Interfaces: Usb Port X 1, Operating Temperature: 0 ~ 40ºc, Altitude: 0 ~ 1000M, Relative Humidity: 0 ~ 90% ( Non-Condensing ) , Audible Noise: < 40 Db, Safety: Bis. 3 2. Supplying, Erecting, Testing & Commissioning Of 8 Port Network Poe Switch.10 / 100 / 1000 Base-T, Poe Smart Switch Plus 1 Sfp Erected In Provided Rack Compliant With Ieee 802.3 Standards Complete. 4 3. Supplying And Fixing 6U Hybrid Ip66 Outdoor Mount Server Rack With Pole Mount Bracket ( Dimension-Dxwxh - 500X550x350 Mm ) As Per Specification No. Wg-Nas / Rak. 5 4. Supplying And Installing Outdoor Cat 6 Cable Fr Pvc Sheathed Aluminum Foiled Wrapped Over Alltinned Copper Braided Hdpe Insulated Copper Cat-6 Stp Cable Suitable For Networking Compliant With Ansi / Tia-568.2-D Standards In Provided Conduit / Casing-N-Capping As Per Specification Eccs Tape Armouring, Suitablewith Electro Magnetic Interference, High-Speed Transmission Of Data Such As Analog, Digital, Voice Or Video Signals, Features Uv Resistant Jacket With Mechanical Anti Rodent, Double Sheath Material, Follows International Standards Ansi / Tia-568-C.2 Standards And Iso / Iec 11801, Supports Gigabit Ethernet ( 1000 Base-T ) . 6 5. Supplying, Erecting, Testing & Commissioning Of 32Ch 4K Uhd Ai H.265+ Nvr User Interface: Graphic User Interface ( Gui ) Operating System: Embedded Linuxoperation Mode: Preview, Record, Playback, Backup, Network.Password Security: Multi-Level User Management.Onvif: Support.Video Input: 32Ch 5M / 16Ch4k / 16Ch1080p.Hdmi Output: Supports 2 ( Max: 4K ) .Vga Output: Supports 1 ( Max: 1080P ) .Audio Input: 1 Ch Audio Output:1 Ch, Rca Connector.Display: 1 / 4 / 6 / 8 / 9 / 10 / 13 / 16 / 25 / 32 Optional.Video Standard: Pal / Ntsc.Video Compression: H.265Ai / H.265+ / H.265 / H.264+ / H.264.Intelligent Functions: Trip Wire, Face Detection, Vehicle Detection, Ip Based Pa System, Line Draw.Video Encoding Resolution: 12Mp; 8Mp; 5Mp; 4Mp; 3Mp; 1080Psynchronous Playback 8Chvideo Frame Rate: Pal: 1-25 Fps Ntsc: 1-30Fpsvideo Bit Rate: 1536Kbps-3072Kbpsstream Type: Video & Audio / Videoaudio Compression G.711Arecording Mode: Always / Schedule / Alarm / Recording / Motion Detection Recording.Video Search: Time / Channel / Eventdisplay: Zoom Live Playback & Mobileaudio Bit Rate: 8—32Kbps, Dual-Stream Supportsmobile Monitoring Application For Android And Iphonerecording Resolution 32 Ch Realtime Recording.Hdd Port: 8 Sata Hdd Maximum Capacity: 12Tb For Each Sata Connector.Voice Talk Support, 1Ch Bnc Line In / 1Ch Rca Audio Out.Record Mode Audio & Video Recording Simultaneouslyremote Control Supportsnetwork Protocol Supports Ie / Pppoe / Ddnsincoming Bandwidth: 288Mbps Outgoing Bandwidth: 288Mbpsnetwork 2 Rj45 : 10M / 100M / 1000Musb Connector : 2 X Usb2.0 1 X Usb3.0Firmware Update Support Usb Update / Network Updatealarm Input 16, Alarm Output 4Intelligent Ai Feature Vehicle Detectionpower Supply Atxoperation Temperature -10?--+55?Operation Humidity 10%--90%Certifications Ce, Fcc, Rohs, Bis 7 6. Supplying, Erecting, Testing & Commissioning Of 5Mp H.265+ Ir Bullet Network Camera 80 Meter.Image Sensor 1 / 2.5 5 Megapixel Sony Cmosimage Pixels Max: 2592 X 1944 Pixels ( 5.0 Mega Pixels ) Min. Illumination 0.01Lux @ ( F1.2, Agc On ) , 0Lux With Irday / Night Auto ( Icr ) / Color / Black & Whitewdr =120Dbir Led Yesir Distance80 Meterslens Mount 12.0Mm Fixed Lensnetwork Interface 10 / 100 Mbps Rj45 Connectornetwork Protocol Http, Tcp, Arp, Rtsp, Rtp, Udp, Rtcp, Smtp, Ftp, Dhcp, Dns, Ddns, Pppoe, Ipv4 / V6, Snmp, Qos, Upnp, Ntpelectronic Shutter Speed Manual / Auto ( 1 / 25 ~ 1 / 100000 S ) Ddns Service Free Ddnsonvif Protocol Supportsvideo Encoding H.265+, H.265 And H.264Video Bitrate 128Kbps ~ 8Mbpsvideo Streams Main Stream : 2592 X 1944; Sub Stream 1: 720 X 576; Audio Input Yes 1 Channelaudio Output Yes 1 Channelaudio Bitrate 64Kbps ( G.711 ) / 16Kpbs ( G.726 ) Image Setup Mirror Image / Reverse / Color Settingsalarmmotion Detection, Human Detection, Video Loss, Ipc Alarmai ( Artificial Intelligence ) Vehicle Detection, Face Detection, Active Deterrence, Line Crossingoperation Temperature -10°C ~ +55°Coperation Humidity 0% ~ 90%Power Supply Dc12v / 2Amperespoe Poe ( Ieee802.3Af ) Power Consumption =3.5W ( Without Ir ) Material Metal Body / Abs Housingip Rating Ip67rj45 Connectorweatherproof Rj45 Connectorir Schedule Function Availablecertifications Ce, Fcc, Rohs & Bis 8 7. Supplying, Erecting, Testing & Commissioning Of 5Mp H.265+ Ir Varifocal Bullet Network Camera 30 Meter.Image Sensor 1 / 2.7“ Progressive Scan Cmosimage Pixels 2592 X 1944 Pixels ( 5.0 Mp ) Minimum Illumination Color: [email protected]; B / W: [email protected], Day / Night Auto ( Icr ) / Color / Black & White Wdr ( Wide Dynamic Range ) =140Dbir Led 4 Pcs High Power Led Array Ir Distance 30 ~ 100 Meters, Shutter Type Manual / Auto Shutter Speed 1 / 25S ~ 1 / 100000S Lens Mount 2.8Mm~12.0 / 6.0Mm~22.0Mm / 5~50Mmmotorized Auto-Focus Lenssd Card Supported ( Max: 512 Gb ) Network Interface 10 / 100 Mbps Rj45 Connectornetwork Protocol : Http, Tcp, Arp, Rtsp, Rtp, Udp, Rtcp, Smtp, Ftp, Dhcp, Dns, Ddns, Pppoe, Ipv4 / V6, Snmp, Qos, Upnp, Ntpvideo Encoding H.265Ai / H.265+ / H.265 / H.264+ / H.264Video Bitrate 128Kbps ~ 8Mbpsvideo Streams Triple Stream Video Stream Resolution Max : 2592 X 1944; 2304 X 1296; 1920 X1080; 720 X 576; 25 / 30 Fpsdigital Zoom Supported ( Max: 16X ) Audio Input Yes; 1Ch; 2Vp-P 1K?, Audio Output Yes; 1Ch; 16?Audio Compression G.711Aimage Setup Mirror Image / Reverse / Color Settingsalarm Yes, Intelligent Ai Feature Face Detection, Vehicle Detection, Human Detection, Active Deterrence, Line Crossing, Trip Wireoperation Temperature -10°C ~ +65°Coperation Humidity 0% ~ 90%Power Supply Dc12v, Poe ( Ieee802.3Af ) ( Class 0 ) Power Consumption =3.6W Without Ir; =8W With Irmultiple Browsers Supports ( Chrome, Mozilla, Edge, Opera ) Housing Material Aluminum + Absingress Protection Ip67certifications Ce, Fcc, Rohs, Bis. 9 8. Supplying, Erecting, Testing & Commissioning Of 5Mp 44X H.265+ Network Speed Dome Ptz Camera.Image Sensor 1 / 2.7 5Mp Progressive Scan Cmoslens 4.5Mm ~ 165Mm ( 44X Optical Zoom ) Iris Auto / Manual ; F1.6 ~ F4.8Shutter Auto / Manualshutter Time 1 / 2S ~ 1 / 20000Sminimum Illumination Color: 0.1 Lux B / W: 0.01 Lux ( Ir On: 0.0 Lux ) S / N Ratio = 50Dbday / Night Mode Ir-Cut Filter With Auto Switch ( Icr ) Ir Distance 300 Metersvideo Compression H.265+, H.265 & H.264Video Resolution 2592 X 1944 Pixels ( Max ) Video Streaming Triple Streams Osd Up To 8 Osdsprivacy Mask Up To 8 Areasdigital Zoom Supportsnetwork Protocols L2tp, Ipv4, Igmp, Icmp, Arp, Tcp, Udp, Dhcp, Pppoe, Rtp, Rtsp, Qos, Ntp, Ftp, Http, Snmp, Sipcompliance Onvifpan Range 360° Endlesspan Speed 0.02° / S~120° / Stilt Range -15° ~ +90° ( Auto-Reverse ) Tilt Speed 0.1° / S~160° / Sauto Flip Pan: 180°; Tilt: 93°A.I ( Artificial Intelligence ) Face Detection, Vehicle Detection, Line Crossing, Active Deterrencepresets 220 Presetsdwell Time 1S ~ 60S Selectable Guard Tours Minimum 3 Toursguard Points Min: 16 Points Per Tourpark Time 1 ~ 60 Minutesnetwork 10M / 100M Base-Tx Ethernetlocal Storage Micro Sd Card Upto 256Gbdigital Defog Availableworking Temperature -40°C ~ +65°Cworking Humidity =90% Rh ( Non Condensing ) Ingress Protection Ip67lightning Protection Transient Voltage 6000Vcertifications Ce, Fcc, Rohs & Bis 10 9. Supplying, Erecting, Testing & Commissioning Of 6Mp H.265+ Ir Dome Network Camera 50 Mtr.Image Sensor: 1 / 2.7“Progressive Scan Cmosimage Pixels: 3072 X 2048 Pixels ( 6.0Mp ) Minimum Illumination Colour: [email protected]; B / W: [email protected] / Night Auto ( Icr ) / Colour / Black & Whitewdr ( Wide Dynamic Range ) : =140Dbir Led: 24 Pcs Smd Ir Ledir Distance: 50 Metersshutter Type Manual: / Autoshutter Speed: 1 / 25S ~ 1 / 100000S Lens Mount: 2.8Mm~12.0 / 6.0Mm~22.0Mm / 5~50Mm Motorized Auto-Focus Lenssd Card: Supported ( Up To 512 Gb ) Network Interface: 10 / 100 Mbps Rj45 Connectornetwork Protocol: Http, Tcp, Arp, Rtsp, Rtp, Udp, Rtcp, Smtp, Ftp, Dhcp, Dns, Ddns, Pppoe, Ipv4 / V6, Snmp, Qos, Upnp, Ntpvideo Encoding: H.265Ai / H.265+ / H.265 / H.264+ / H.264Video Bitrate: 128Kbps ~ 8Mbpsvideo Streams: Triple Streamvideo Stream Resolution: Max: 3072 X 2048; 2592 X 1944; 1920 X 1080; 720 X 576; 25 / 30 Fpsdigital Zoom: Supported ( Max: 16X ) Audio Input: Yes; 1Ch; 2Vp-P 1K? Impedance Audio Output: Yes; 1Ch; 16? Impedanceaudio Compression: G.711A ( Optional ) Image Setup: Mirror Image / Reverse / Colour Settingsalarm: Yesintelligent Ai Feature: Face Detection, Vehicle Detection, Human Detection, Active Deterrence, Line Crossing, Trip Wireoperation Temperature: -10°C ~ +65°Coperation Humidity: 0% ~ 90%Power Supply: Dc12v, Poe ( Ieee802.3Af ) ( Class 0 ) Power Consumption: =3.6W Without Ir; =8W With Irmultiple Browsers: Supports ( Chrome, Mozilla, Edge, Opera ) Housing Material: Aluminiumingress Protection: Ip67certifications: Ce, Fcc, Rohs, Bis. 11 10. Supplying & Erecting 55 Professional Led Display With 1920 *1080 ( Full Hd ) Display, Suitable For 32 / 64 Channel Nvr And Following Features, Brightness: Minimum 500 Cd / M2contrast Ratio: Minimum 1000:1 Viewing Angle: 178 / 178 Deg.Response Time: Maximum 8 Ms, Inputs: Hdmi, Vga, Bnc, Usb, Audio In, Built-In Speakers Maximum 10 W, Suitable To Operate On 100-240 V 50 Hz Ac Supply And 24 / 7 Duty Cycle Duly Erected On Wall Or Table Top With Standard Accessories Like Wall Mount Stand And Wiring Connections Etc. Complete As Per Specifications. 12 11. Supplying & Erecting 4 Tb Internal Surveillance Hdd.Suitable For Sata Port Of Nvr, Interface Transfer Rate 6 Gb / S, Maximum Sustained Transfer Rate 150Mb / Sec To 180Mb / S. Drive Bay Supported 08+, Cameras Supported Up To 64, Cache ( Mb ) 64, Load / Unload Cycle -3000000, Work Load Rating Per Year 180Tb, Mtbf 1000000 Hrs. Https. Rohs, Ul, Ce Certified, Duly Erected In Position In Provided Nvr As Per Specification. 13 12. Supplying, Erecting, Testing & Commissioning Of Server With Video Management Software.The Unified Video Management Software ( Vms ) Shall Be Ip-Enabled Security & Safety Software Solution. The Vms Shall Support Industry Standard For The Interface Of Ip-Based Physical Security Products, Onvif And Shall Be Based On A Server / Client Model. The Vms Shall Be Based On A True Open Architecture That Shall Allow For Use Of Non-Proprietary Workstation And Server Hardware, Non-Proprietary Network Infrastructure And Non- Proprietary Storage. The Vms Shall Offer A Complete And Scalable Video Surveillance Solution Which Allows Cameras To Be Added On A Unit-By-Unit Basis. All Software And Firmware Upgrades Shall Be Free Of Charge During The Warranty Period. The Vms Should Support Multiple Recording Server Should Be Expandable To Unlimited Number Of Cameras Should Have Scalable Distributed Network Architecture Supporting Multiple Recording Servers Per Management Server. Vms Shall Be Open To Any Ip And Analog Cameras Integration. It Should Support Windows Operating System On Server Machine. The Vms Shall Consist Of A Role-Based Architecture; Roles Can Be Moved From One Server To Another Without Disturbing The Regular Operations. It Should Support Video Wall And Multiple Monitor Support For Scalable Video Display Of Large Number Of Cameras. ( 64 Cameras X 4 Screen ) It Should Support Four Plex Mode Via Live View, Recording And Playback Simultaneously. It Should Support E-Maps Showing Real Time Device Alarms With Option To View Live Or Recorded Video It Should Support Recording Of All Video Streams Supplied From Ip Cameras / Encoders. The Same Shall Be Digitally Encoded In Mpeg-4, Mpeg-2, Mjpeg, H.264 Or Compression Formats And Can Be Recorded Simultaneously In Real Time. It Should Support Recording Of All Video Streams Supplied From Ip Cameras / Encoders. The Same Shall Be Digitally Encoded In Mpeg-4, Mpeg-2, Mjpeg, H.264 Or Compression Formats And Can Be Recorded Simultaneously In Real Time. Vms Features The Software Should Have The Following Features Supported: Should Allow Configuration All Functionalities Of The Camera Once The Same Is Connected To The Software. Should Allow The Configuration Of The Following Camera Parameters As Mentioned Below: Discovery On Ip Network And Set Ip Address, Frame Rate, Resolution, Motion Detection Within Camera Or Server Based, Bit Rate, Key Frame Interval, Digital I / O, Audio Inputs / Outputs, Facilitate Update Of Camera Or Encoder Thru The Vms The Vms Shall Allow Independent Configuration Of Each Camera And It Shall Also Have A Configuration Tool To Copy A Specific Or All Configuration On Other Cameras. 14 13. Ip Based Public Address System With Existing Cctvweather Proof Horn Type Speaker ( 15 Watt ) Housing: Special Plastic / Die Cast Aluminium / Polyester Resin Armoured With Fibreglass / Equivalent Industrial Grade Material. Ingress Protection: Ip65 Rated Power: 15-Watt Frequency Range: 370Hz To 7000Hz Dispersion-6Db-: 140° / 40° 1 Khz / 4Khz. Indoor Speaker ( 10 Watt ) Housing: Special Plastic Ingress Protection: Ip32 Rated Power: 10-Watt Effective Frequency Range: 100 To 20000Hz. Zone Station Wireless Microphone Hands-Free, Wall Mounted / Desk Top, Dual Direct. • Location Indoor / Outdoor • Mounting Desk / Wall Mounted • Protection Corrosion Resistant & Pilfer Proof. • Protection Class Ip65 • Body Heavy Duty Grp. • Microphone Type Gooseneck ( >400Mm ) . • Volume Control Via Keypad. • Body Moulded Polyurethane • Operating Voltage 24 V Dc Distance 2Km ( Max. ) • Loudspeaker Output Yes. 15 14. Supplying And Erecting Lszh Armoured Multimode Optical Fiber Cable. With 6 Fibers, Core Dia 50 / 125 Μm ( Om4 ) , Suitable Upto 10 Gbps, Compliant To Iec 60793 / Iec 60794 Standards, On Wall / Ceiling Or Laid In Provided Pipe / Trench As Per Specification 16 15. Supplying And Installing 6 Port Single Mode Fiber Adapter Panel Suitable For Fc, Lc, Sc, St Adapters With Ss Plate Complete. 17 16. Supplying And Fixing 24 Ports Liu. Light Guide Unloaded Interconnect Unit, Wall Mounted Type, With Adapter Panel For Termination Of Optical Fiber Cables On Wall In Provided U Rack Complete As Per Specification 18 17. Supplying And Fixing Ip66 Abs Enclosure. For Fiber Splicing With Raised Hinged Splice Trays To House Upto 48 Fibers With Multiple Gland Entry Points Including Heat Shrink Splice Protectors Complete. 19 18. Supplying And Fixing 3 M Utp Patch Cord. 24 Awg Multi Stranded, Utp Patch Cord Of Enhanced Cat 6A Type, Compliant Ansi / Tia-568.2-D Standards In Position As Per Specification. 20 19. Supplying And Fixing Cat 6A 24 Port Patch Panel With Keystone Jacks Compliant With Ansi / Tia / Eia 568.C.2 & Iso / Iec 11810 Complete As Per Specification. 21 20. Supplying And Fixing 42U Floor Mount Server Rack ( Dimension-Dxwxh –800X1000x2070 Mm ) As Per Specification. 22 21. Supplying, Fixing And Configuring Media Converter.1000 Base-T To 1000 Base-Sx ( Sc ) Single Media Converter For Transmission Distance Upto 10 Km With Led Indication Complete As Per Specification. 23 22. Supplying, Fixing, And Configuring 10G Base -Lr ( Sfp+ ) Sm Transceiver Compliant With Ieee 802.3 Standards Erected In Provided Rack Complete. 24 23. Supplying And Installing Single Mode Simplex Pigtail With Sc / Lc Splicing Complete. 25 24. Supplying And Plugging 3 M Fiber Patch Cord Lc-Lc Mm ( 50 ) Om4 Lszh Duplex, Compliant To Iec 60793 / Iec 60794 Standards, Complete As Per Specification. 26 25. Supplying And Fixing Poe Adaptor To Provide Dc Supply To Ethernet Devices As Per Specification. 27 26. Supplying, Fixing, And Configuring Of 24 Port Layer 3 Switch. 20 ( 1G-Rj45 ) Ports + 4 Combo 1G Ports + 4 10G ( Sfp+ ) Ports, Layer 3 Switch, 6Kv Surge Protection On Ethernet Port And Console Port For Management & Support Ospf, Bgp, Mpls, Policy Based Routing Compliant With Ieee 802.3 Standards Erected In Provided Rack Complete. 28 27. Providing & Erecting 6 M High Pole. ( Clear Height ) Galvanised Octagonal Pole With Foundation Bolts Having Bottom Of 130 Mm A / F, Top 70 Mm A / F On Provided Foundation As Per Specification. 29 28. Supply, Installing, And Testing Of Maintenance Free Earthing.Comprising Of Electrode Of 17.2 Mm Diameter Low Carbon Steel With 250 Micron Molecular Copper Bonded Earthing Rod Of Length 3M Along With Carbon Based Environment Friendly Back Fill Ground Enhancing Compound Required To Fill Up The Excavated Earth With Required Quantity ( Min. 125Kg ) Complete, And Recording The Results Specification. 30 29. Supplying, Erecting, Testing & Commissioning Of 3 Kva Capacityon Line Pure Sine Wave, Pwm, Igbt Based Ups With 0.8 To Unity Output Pf , Single Phase Input & 1 Phase Output Complete With All Protections As Per Specification ( Without Batteries ) . 31 30. Supplying And Erecting 12 V / 65Ah Smf Battery With Battery Terminal Wire, Duly Charged Complete With 24 Months Warranty Complete. 32 31. Supplying And Fixing Power Distribution Unit For Networking Rack Comprises Of 6 / 16A ( 6 Nos. Sockets ) , 16A Modular Mcb, Appropriate Rating, Enclosed In Black Powder Coated Metal With Necessary Arrangement For Fixing Complete. 33 32. Supplying, Erecting & Terminating 25 M Hdmi Cord Low Voltage Grade Minimum 4K Compliant To Be Laid In Provided Conduits With Male / Female 19Pin Hdmi Connectors Complete. 34 33. Supplying, Installing And Testing Utp Connector ( Rj-45 ) As Per Specification. 35 34. Supplying, Fixing, And Configuring Broadband Router With All Accessories On Provided Rack. 36 35. Making Trench In Hard Murum / Tar Road Having 0.9M Depth And Minimum 0.3M Width For Laying Provided Cables Of Voltage Range 3.3Kv To 11Kv Complete As Per Specification. 37 36. Ptz Joystick Cintroller Support Onvif 2.4, Back-End Ptz Is Not Limited By Manufacturers, Easily Achieve Cruise, Pattern Scan And Etc. Plug And Play Without Any Setting, Automatically Add And Distribute Ip Address Support 3D Control, Support 1-64 Level Speed Limit Function , Precise Positioning, Control Agility Improve Operation Speed &Channel Switching Speed Support English Osd Menu, Support 5 Inch Led, Hd Lcd Screen, Control Equipment, Real Time Images Display Support Unlimited Number Of Dome Cameras Insert Support Usb & Hdmi Output, Automatic Matrix Switch Function Support H.265 Decoding, High Compatibility Increase Rocker Vector Control And Control Of The Speed Of The Platform According To The Amplitude Of The Rocker The Key Is Change To The Big And Soft Key , And The Feeling Is More Comfortable. 38 37. Supplying And Laying Of Hdpe Pipe.50 Mm Outside Dia. Double Wall Corrugated Pipes ( Dwc ) Of Hdpe For Enclosing Cable Below Ground / Road Surface, Complete.
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 3
Maharashtra View Result →
19.
Power #9158096 Technical Bid
Rate Contract For Upkeep / Maintenance Of 66-33 / 11 Kv Receiving Stations Along With Their 66 / 33 Kv Lines And Fabrication & Handling Of Material Of Divisional Store Under The Jurisdiction Of Sub Transmission Division, Jpdcl, Kathua For The Year 2022-23 Or Till The Next Contract.- 1 Erection Of 16 Mtr Long Steel Tubular Pole With Planting Depth Of 1 / 6 Th Of The Height Of The Pole Including Digging Of Pits, Disposal Of Extra Earth, Collection Of Boulders And Filling Back. 2 Erection Of 13 Mtr Long Steel Tubular Pole With Planting Depth Of 1 / 6 Th Of The Height Of The Pole Including Digging Of Pits, Disposal Of Extra Earth, Collection Of Boulders And Filling Back. 3 Erection Of 11 Mtr Long Steel Tubular Pole With Planting Depth Of 1 / 6 Th Of The Height Of The Pole Including Digging Of Pits, Disposal Of Extra Earth, Collection Of Boulders And Filling Back. 4 Erection Of 11 Mtr Long Pcc Pole With Planting Depth Of 1 / 6 Th Of The Height Of The Pole Including Digging Of Pits, Disposal Of Extra Earth, Collection Of Boulders And Filling Back. 5 Erection Of 9 Mtr Long Steel Tubular Pole With Planting Depth Of 1 / 6 Th Of The Height Of The Pole Including Digging Of Pits, Disposal Of Extra Earth, Collection Of Boulders And Filling Back. 6 Erection Of 9 Mtr Long Pcc Pole With Planting Depth Of 1 / 6 Th Of The Height Of The Pole Including Digging Of Pits, Disposal Of Extra Earth, Collection Of Boulders And Filling Back. 7 Painting Of 16 Mtr Long Steel Tubular Poleincluding Fixtures With One Coat Of Red-Oxide And Two Coats Of Silver ( Aluminium ) Paint 8 Painting Of 13 Mtr Long Steel Tubular Poleincluding Fixtures With One Coat Of Red-Oxide And Two Coats Of Silver ( Aluminium ) Paint 9 Painting Of 11 Mtr Long Steel Tubular Poleincluding Fixtures With One Coat Of Red-Oxide And Two Coats Of Silver ( Aluminium ) Paint 10 Painting Of 09 Mtr Long Steel Tubular Poleincluding Fixtures With One Coat Of Red-Oxide And Two Coats Of Silver ( Aluminium ) Paint 11 Cement Bottoming In 1:2:4 Mix Including Excavation And Form Work As Per Rec Standards. ( 16 / 13 / 11 / 9 Mtr Long Poles ( Complete Job ) 12 Fixing Of Galvanisedspiral Earthing Of Swg No. 8, G.I Wire Of 115 Turns Confirming To Rec-J1 Construction Standard, ( J1 ) 13 Fixing Of 66 / 33Kv Galvanised Guy Set ( Guy Wire, Guy Rods, Turn Buckle Plate , Guy Insulators ) Confirming To Is 2141 / 1979 Or The Latest Version Thereof Including Digging Of Pits & Refilling 14 Collection Of Snapped Acsr Cond. And Re-Stringing, Tensioning , Binding Of Acsr Conductor, ( 100Mm2 Acsr Conductor ) 15 Collection Of Snapped Acsr Cond. And Re-Stringing, Tensioning , Binding Of Acsr Conductor, ( 150Mm2 Acsr Conductor ) 16 Collection Of Snapped Acsr Cond. And Re-Stringing, Tensioning , Binding Of Acsr Conductor, ( 200Mm2 Acsr Conductor ) 17 Dismantling Of Steel Tubular Pole Including Carriage Up To Dumping Site, ( 16 Mtr. Long ) Up To Distance Of 50 Mtr 18 Dismantling Of Steel Tubular Pole Including Carriage Up To Dumping Site, ( 13 Mtr. Long ) Up To Distance Of 50 Mtr 19 Dismantling Of Steel Tubular Pole Including Carriage Up To Dumping Site, ( 11 Mtr. Long ) Up To Distance Of 50 Mtr 20 Dismantling Of Pcc Pole Including Carriage Up To Dumping Site, ( 11 Mtr. Long ) Up To Distance Of 50 Mtr 21 Dismantling Of Steel Tubular Pole Including Carriage Up To Dumping Site, ( 9 Mtr. Long ) Up To Distance Of 50 Mtr 22 Dismantling Of Pcc Pole Including Carriage Up To Dumping Site, ( 9 Mtr. Long ) Up To Distance Of 50 Mtr 23 Dismantling Of Three / Four Pole Structure, Opening Of Channels, Crossarms, Angles ( Complete Job. ) 24 Dismantling Of Two Pole Structure, Opening Of Channels, Crossarms, Angles ( Complete Job. ) 25 Straightening Of Tilted Steel Tubular Pole ( 16 Mtr. Long ) 26 Straightening Of Tilted Steel Tubular Pole ( 13 Mtr. Long ) 27 Straighteningof Tilted Steel Tubular Pole ( 11 Mtr. Long ) 28 Straighteningof Tilted Pcc Pole ( 11 Mtr. Long ) 29 Straighteningof Tilted Steel Tubular Pole ( 9 Mtr. Long ) 30 Straighteningof Tilted Pcc Pole ( 9 Mtr. Long ) 31 Unloading Of Steel Tubular Pole Including Carriage Up To Dumping Site, ( 16 Mtr. Long ) Up To Distance Of 50 Mtr 32 Unloading Of Steel Tubular Pole Including Carriage Up To Dumping Site, ( 13 Mtr. Long ) Up To Distance Of 50 Mtr 33 Unloading Of Steel Tubular Pole Including Carriage Up To Dumping Site, ( 11 Mtr. Long ) 34 Unloading Of Steel Tubular Pole Including Carriage Up To Dumping Site, ( 9 Mtr. Long ) Up To Distance Of 50 Mtr 35 Loading Of Steel Tubular Poles Including Carriage Up To Dumping Site, ( 16 Mtr. Long ) 36 Loading Of Steel Tubular Poles Including Carriage Up To Dumping Site, ( 13 Mtr. Long ) 37 Loading Of Steel Tubular Poles Including Carriage Up To Dumping Site, ( 11 Mtr. Long ) 38 Loading Of Steel Tubular Poles Including Carriage Up To Dumping Site, ( 9 Mtr. Long ) 39 Extra Carriage From Dumping Site, ( 16 Mtr. Long ) Up To Site Of Work 1St 100 Mtr 40 Extra Carriage From Dumping Site, ( 13 Mtr. Long ) Up To Site Of Work Ist 100 Mtr 41 Extra Carriage From Dumping Site, ( 11 Mtr. Long ) Up To Site Of Work Ist 100 Mtr 42 Extra Carriage From Dumping Site, ( 9 Mtr. Long ) Up To Site Of Work Ist 100 Mtr 43 Unloading Of Steel Of Sorts , ( Steel ) 44 Loading Of Steel Of Sorts , ( Steel ) 45 Unloadingof Conductor Reels, ( 100Mm² / 150Mm² / 200Mm² Acsr Conductor ) 46 Loadingof Conductor Reels, ( 100Mm² / 150Mm² / 200Mm² Acsr Conductor ) 47 Fixing Of 66-33 Kvdiscinsulator ( 70 Kn ) 2008 Standards, ( Porcelain ) 48 Fixing Of 66-33 Kv Disc Fitting ( 70 Kn ) 2008 Standards, ( Polymer ) 49 Fixing Of 66-33 Kv Insulators ( 10 Kn ) Standards, ( Porcelain ) 50 Fixing Of 66-33 Kv Pin Insulators ( 10 Kn ) Suitable For 100 / 150 / 200Mm² Acsr Conductor. 51 Replacement / Fixing Of 66-33 Kvtension Fittings ( Socket & Ball Type Or T&C Type ) For Acsr 52 Replacement / Fixing Of 66-33 Kv Tension Fittings ( Socket & Ball Type Or T&C Type ) For Acsr 150M² 53 Replacement / Fixing Of 66-33 Kv Tension Fittings ( Socket & Ball Type Or T&C Type ) For Acsr 200M² 54 Straighteningof X-Arms Of Different Sizes ( 100X50x50x6 Mm Channel Iron, 50X50x6mm Angle Iron ) Duly Painted With One Coat Of Red-Oxide And Two Coats Of Silver Paint Fixing With Different Sizes And Sorts Of Nuts, Bolts And Washers, ( Channel Iron X-Arms, Angle Iron-X-Arms, Pole Tops ) 55 Straighteningof Angle Ironof Different Sizes ( 65X65x6 Mm Channel Iron, 50X50x6mm Angle Iron 56 Repair And Re-Erection Of Cradle For Guard Netting With Gi Wire 8No Including Wire Binding, Cutting / Bending Of Gi Wireas Per Rec Standards 57 Branch Cutting, 66- 33 Kv Lines 58 Removing Of Wild Climbers / Vegetation Around 66 / 33 Kv Poles 59 Removing Of Wild Climbers / Vegetation Around 66 / 33 Kv Tower 60 Removing Of Wild Climbers From Top Of 66-33 Kv Lines. 61 Removing Of Wild Climbers From Peak, Cage, Cross Arm Of 66-33 Kv Old Tower Line 62 Patrolling Of 66 / 33 Kv Line ( Routine / Under Fault ) 63 Tightening Of Loose Guys 64 Dismantling & Re-Erection Of Damaged Guys Including Digging Of Pit & Refilling The Same 65 Replacement Of Damaged Disc Insulator In Tension String 66 Replacement Of Cross Arms Of Sizes 100X50x6 67 Replacement Of Angle Iron Of Sizes ( 65X65x6, 50X50x6 ) 68 Replacement Of Pin Insulator On Four / Three / Double Pole Structure 69 Replacement Of Pin Insulator On Single Pole Structure 70 Replacement Of Worn-Out / Damaged Jumper Of 66-33 Kv Towerlines 71 Replacement Of Disc Insulator, Suspension Fitting Of 66-33 Kv Towerlines 72 Replacement Of Worn-Out / Loose / Damaged Jumper Of 66-33 Kv Lines ( Sets Of3 Nos ) 73 Local Earthing Of 66 / 33 Kv Lines By Way Of Using Discharge / Earth Rods At Faulty Site To Avoid Accident Due To Any Induction While Working On Line. 74 Tightening / Restringing Of Loose Acsr Dog 100 Mm2 75 Tightening / Restringing Of Loose Acsr Wolf 150 Mm2 76 Tightening / Restringing Of Loose Acsr Panther200 Mm2 77 Dismantling & Re-Erection Of Acsr Dog 100Mm2 Including Collection Of Dismantled Conductor , Making Of Small Bundles And Its Carriage 78 Dismantling & Re-Erection Of Acsr Wolf 150Mm2 Including Collection Of Dismantled Conductor , Making Of Small Bundles And Its Carriage 79 Dismantling & Re-Erection Of Acsr Panther 200Mm2 Including Collection Of Dismantled Conductor , Making Of Small Bundles And Its Carriage 80 Dismantling Of Stay Sets Complete 81 Upkeep / Maintenance Of 66-33 / 11 Kv Receiving Sub Stations A ) Routine Maintenance Of 66 Kv Outdoor Sf6 By Way Of Tightening Of Loose Nuts And Bolts, Greasing / Lubrication Of Movable Parts, Checking The Movable Alignment Of Different Phases, Cleaning Of Insulating Chambers, Etc 82 33 Kv Vcb Repairs & Renovationby Way Of B ) Setting Of Mechanical Assembly / Replacement Of Damaged Spring / Repair Of Locking & Charging System 83 C ) Replacement Of Tripping Coil / Closing Coil 84 D ) Replacement Of Damaged Vacuum Interrupter 85 E ) Replacement Ofbushing Including Clamps 86 66 Kv C&R Panel: Replacement Of Different EquipmentSa ) Ammeter, Volt Meter Indication , Lamps, Fuses, Trip Close Switch , Selector Switchidentification Of Panel Wiring Faults & Its Rectification 87 33 Kv C&R Panel: Replacement Of Different EquipmentSa ) Ammeter, Volt Meter Indication , Lamps, Fuses, Trip Close Switch , Selector Switchidentification Of Panel Wiring Faults & Its Rectification 88 B ) Replacement Of Different Relays - Mitnumerical Relay / Electro-Mechanical Relay / Master Trip Relay / Differential Relay / Auxiliary Relay Etc. 89 Installation, Testing, Commissioning Of 66-33 Kv Control Relay Panels ( Complete Job ) 90 Complete Testing Of Relays Setting Of Testing Kit, Interconnection Between Various Points Of Panel With Respect Tosecondary Injection Key On Various Current Taps, Recording The Observation Thereof. All Modifications Necessary To Achieve Desired Results. 91 Control Cable Replacement Of Damagedcontrol Cables Of All Typesincluding Binding With Pvc Belts / Binding Wire, Peeling Of Insulation And Fixing Of Proper Size Thimble Connecting The Cable After Identification Of Each Core To Both Ends I.E. Panel To Cts / Panel Topts / Panel To Breaker And Making Functional Of 33 Kv Outdoor Breakers, Protection , Alarms, Annunciation ( Complete Job ) 92 Upkeep Of Earthing Of Aux. Transformer 93 Upkeep Of Earthing Of Power Transformer 94 Upkeep Of Earthing Of 66 / 33 / 11 Kv La 95 Providing Of Extra Earthing For Improvement Purpose ( Complete Job ) 96 Upkeep Of Earth Mat Of Out Door Yard 97 Replacement Of Damaged Earth Mesh In Sub-Station As Per Approved Map & Design. 98 Excavation Of Trenches Of 0.6 Mtr Depth And 2.0 Mtr Wide Mtr In Normal Soil / Hard Soil 99 Repairing / Laying Of Ms Flat And Ms Rod In Deep Excavated Trench And Welding Of Ms Flat & Ms Rod With Mesh. 100 Repairing Of Earthing With Spikes Of Ms Rod 20Mm, 3 Mtr In Length As Per Rec Drawing 101 66-33 / 11 Kv Power Transformera ) Opening Of Transformer Tank Top Cover To Prevent Oil Leakage From Top ( If Required To Facilitate Maintenance Of Transformer After Removing The Required Accessories ) , , Draining / Re-Filling Of Required Oil, Change Of Gaskets Of Valves / Radiators / BuchholzS Relay Radiators Valves Of Power Transformer Of Capacity: 3.15 Mva To 20 Mva 102 B ) Replacement Of Silica Gel 103 C ) General Inspection By Through Inspection Of Each Individual Parts, Ratio Test By Applying Voltage On Hv Side And Measuring Lv Voltage On Various Tap Positions, Checking Of Buchholz Relay, Surge Relay Conservator, Sensors, Measurement Of 1R-Value Dialectic Strength Of Oil, Cleaning Of Power Transformer Etc 104 D ) Replacement Of Any One Of The Following I.E. Temperature Indicators, Gas Operated BuchholzS Relay, Oil Temperature Indicator, Winding Temperature Indicator Etc 105 E ) Preventing Of Leakage By Changing Main Gaskets After Removing The Old Gasket, Replacement Of Hv / Lv Busing & Bush Rod, Ring And Rubber Washers ( Complete Job To Prevent Leakages ) 106 F ) Cleaning Of Scale Deposited Over The Body And Radiators Of The Power Transformer With Thinner / Detergent And De-Rusting In Perfect Manner. ( Routine Work ) 107 G ) Cleaning Of Lv / Hv Bushings Of Power Transformer ( Routine Work ) 108 H ) Replacement Of Bus Bars Ofpower Transformer 109 I ) Replacement Of Lv / Hv Clamps Of Power Transformer 110 Oil Topping Of Power Transformer 10 Mva To 20 Mva 111 Oil Topping Of Power Transformer 4 Mva To 6.3 Mva 112 Oil Topping Of Power Transformer 3.15 Mva 113 Recording Of Ir Values Of Transformers 114 Installation, Testing And Commissing Of Power Transformer 66-33 / 11 Kv Installation Of Lv / Hv Bus Bars With Proper Care, Of Transformer For Any Leakagecommissioning Of Power Of Transformers By Applying Low Voltageapproximately Equal To Impedance Voltage On Hv Side And Short Circuiting The Lv Terminals, Energizing The Transformer By Applying Required Primary Voltage To It & Keeping The Transformer On No Load To Observe The Behaviour Of Transformer, Setting On 25% Of The Load On The Transformer For A Period Of At Test 6 Hours And Observation Of Oil Including Temperature, Increase The Transformer Is Fully Loaded And Topping Of Oil.A ) 20 Mva 115 B ) 10 Mva 116 C ) 6.3 Mva 117 D ) Upto 5 Mva 118 Checking And Tightening Of Jumpers, Droppers In 66 / 33 Kv Outdoor Yard 119 Replacement Of T / Pg Clamps 120 Replacement Of Disc Insulators Including Its Hardware. 121 66 / 33 Kv La & 11 Kv Stn. Type Lareplacement Of 66 Kv, 33 Kv & 11 Kv Lightening Arrestor Including Jumpering And Earth Connecting In All Respect. A ) 66 Kv La 122 B ) 33 Kv La 123 B ) 11 Kv La 124 Separate Pipe Earthing / G.I Rod Earthingas Per Rec Drawing 125 Replacement Of Pipe Earthing / Rod Earthing With New One 126 Installation, Testing And Commissioning, Replacement Of 66 Kv Isolators 127 Installation, Testing And Commissioning, Replacement Of 33 Kv Isolators 128 Replacement Of11 Kv Isolators 129 Repair & Renovationof 66 / 33 Kv And 11 Kv Isolators Including Setting Right Its Alignment For Proper Operation, Lubrication / Greasing Of Jaws, Bearings OperatingS Handle Etc ( Complete Job ) 130 Replacement Of Worn-Out / Heated Pad Clamp / Isolator Clamps Of 66 / 33 / 11 Kv Isolator By Way Of Dismantling. Drilling Of Holes On New And Fixing ( Complete Job ) 131 Repair & Renovationof Isolator Jaws 66 / 33 Kv And 11 Kv Isolators. ( Complete Job ) 132 Replacement Of Post Insulator / Tendon Pipes / Operating Box By Way Of Dimentalling, Necessary Fabrication Where Ever Required For Proper Operation Of 66 / 33 / 11 Kv Isolators. 133 66-33 Kv Ctsinstallation, Testing And Commissioning Of 66-33 Kv Cts ( Of All Ratios ) Complete Job 134 66-33 Kv Ctsrepairs & Renovation Of 66 / 33 Kv Cts By Way Of Replacing Shorting Strips, Connecting Rod, Transformer Oil, Damaged Insulator ( CtS Of All Ratios ) 135 Replacement Of 66 Kv Outdoor Type Ct Of Different Ratio And Dismantling Of Damaged Ct ( CtS Of All Ratios ) 136 Replacement Of 33 Kv Outdoor Type Ct Of Different Ratio And Dismantling Of Damaged Ct ( CtS Of All Ratios ) 137 Oil Topping Of 66 / 33 Kv Ct & Pt By Way Of Opening Of Top Cover And Refixing With New Gaskets If Necessary And Preventing Of Oil Leakages If Any. ( Complete Job ) 138 66-33 Kv Ptsinstallation, Testing And Commissioning Of 66-33 Kv Pts ( Complete Job ) 139 66 Kv Ptsreplacement Of 66 Kv Outdoor Type Pt And Dismantling Of Damaged Pt, Dragging To Installation / Loading Site, Lifting From Ground To Steel Structure. 140 33 Kv Ptsreplacement Of 66 Kv Outdoor Type Pt And Dismantling Of Damaged Pt, Dragging To Installation / Loading Site, Lifting From Ground To Steel Structure 141 66 Kv Post Insulatorreplacement Of 66 Kv Post Insulatorand Dismantling Of Damaged Pi, Dragging To Installation / Loading Site, Lifting From Ground To Steel Structure. 142 33 Kv Post Insulatorreplacement Of 33 Kv Post Insulatorand Dismantling Of Damaged Pi, Dragging To Installation / Loading Site, Lifting From Ground To Steel Structure. 143 Cleaning Of Porcelain Bushing, Tightening Ofpt / Ct Clamps, Derusting & Painting Of Body Of 66 / 33 Kv Pts & Cts 144 Tightening Of Nuts & Bolts, Replacement Of Oval Thread Bolts, Chipping By Way Of Welding To The Bolts After Tightening In A Single Bay 145 Painting With Mix Red Oxide Paint Two Coats Of Approved Make On Steel Works After Cleaning With Wire Brush / Sand Paper 146 Painting Of Steel Structure Erected In Outdoor Yard With Aluminium Paint Two Coats With Approved Brand Andfixture To Given An Even Surface 147 Battery Banka ) Repair & Maintenance Of Battery Set Including Maintaining Specific Gravity, Electrolyte Level, Cleaning, Checking, Tightening Of Battery Terminals In All Respects It Includes Measuring Voltage Of Each Battery. 148 B ) Tightening Of All Nut And Bolts, Replacement Of Damaged Battery Cells 149 C ) Installation, Testing And Commissioning Of Battery Bank ( Complete Job ) 150 Battery Chargerrepair / Renovation Battery Charger For Proper Functioning By Way Of Replacement Of Rectifier Unit, Ammeter, Voltmeter, Mcb, Cooling Fan, Led Indications, Buzzer Alarms For Ov / Uv Etc ( Complete Job ) 151 Repair And Maintenance Of Dc Board, Identification Of Fault In Respect Of Cableand Its Replacement, Replacement Of Damaged Mccb, Kit Kat, Bus Bar & Other Allied Job. 152 Repair And Maintenance Of Ac Board, Identification Of Fault In Respect Of Cableand Its Replacement, Replacement Of Damaged Mccb, Kit Kat, Bus Bar & Other Allied Job. 153 Installation, Testing And Commissioning Of Battery Charger ( Complete Job ) 154 Deweeding Of Vegetation In Outdoor Yardremoving Of Stone Metal, Deweeding Of Unwanted Vegetation, Spreading Of Stone Metal Collected Earlier For Removal Of Vegetation, Levelling The Area With Existing Stone Metal 155 Providing Of Additional Stone Metal And Its Carriage And Laying In Outdoor Yard, This Including Breaking Of Stones Complete Job. 156 Cleaning Of Control Room, Removing Dirt & Dust From The Panels, Walls, Cleaning Of Fixtures ( For One Bank ) 157 Painting Of Internal / External Walls And Roof By Approved Brand Of Oil Based Distemper 158 Painting Of Door And Window Panels Of Control Room By Approved Brand Of Paint 159 Repairs & Renovation Of 11 Kv Vcb, By Way Of Replacement Of A ) Grid-Spout Assembly 160 B ) Replacement Of Damaged Cts Of Different Ratio Testing The Ct With The Help Of Primary Injection Set Fixing In Pannel, Fixing The Secondary Connection After Assessing The Load ( Complete Job ) 161 C ) Thorough Checking Of Control Wiring Circuits, Replacement Of Damaged Wire If Any, Replacement Of Terminal Plates, Tripping Circuits, Close / Trip Switch, Ammeter Switch, Replacement Of Voltmeter & Ammeter . 162 D ) Replacement Of 11 Kv Damaged Pt 163 E ) Replacement Of Blown Fuses, Checking The Pt Terminal With Respect Of 11 Kv Bus Bar Complete Job. 164 F ) Replacement Of Trip / Close Coil 165 G ) Replacement Of Trivector Meter On 11 / 33 / 66 Kv Panels 166 Installation, Testing And Commissioning , Replacement Of Lt Cabele 167 11 Kv Power Cables / 33 Kv Power Cables / 66 Kv Power Cablesa ) Identification Of Damaged Portion Of Cable, Tracing Of Cable, Remove Cable From Trench, Carriage And Laying Of Cable ( Complete Job ) Including Cleaning Of Cable Trenches. 168 B ) Replacement Of Damaged Cable Of Sizes 169 Replacementof Termination Kits Of Different Sizes, Connecting The Cable With Panel And Outgoing Structures After Crimping Of Lugs Fixing With Nuts And Bolts, Checking Of Earth Point, Connecting The Earthing Point Of Cable With Existing Earthing System A ) 11 Kv Indoor Termination Kit ( 1-Phase / 3 Phase ) 170 B ) 11 Kv Outdoor Termination Kit ( 1-Phase / 3 Phase ) 171 C ) 33 Kv Indoor Termination Kit ( Single Phase ) 172 D ) 33 Kv Outdoor Termination Kit ( Three Phase ) 173 E ) 33 Kv Indoor Termination Kit ( Three Phase ) 174 F ) 33 Kv Outdoor Termination Kit ( Single Phase ) 175 G ) 66 Kv Indoor Termination Kit ( Single Phase ) 176 H ) 66 Kv Outdoor Termination Kit ( Single Phase ) 177 Improvement Of Earthing System In Control Room By Way Of Replacement Of Earthing Risers From Earthing Point To Panel / Checking Of All Welding Points / Re-Welding Of Lose Connection, Laying Of Fresh / Additional Earth-Mat Strip To Improve The Existing Earthing System ( Complete One Panel Set ) 178 Checking Of Ir Values 179 De-Watering Of Receiving Station To Avoid Water Logging. 180 Repairing Of Electrical Circuits For Improvement Of Control Room Immunination, Power Points Etc ( Complete Job ) 181 Installation, Testing, Commissiing For Replacement Of Aux. Transformer At Receiving Station 182 On Site Repairing Of Aux Transformer For Missing Phase, Lt Strip, Lt Bush Rod, Lt Bush Cup, Ht Bush Rod Etc ( Complete Job ) 183 Transport Charges For Carriage Of T&P, Men & Material On Urgent Basis During Power Breakdown And Restoration Of System. ( Auto Carrier ) Aditional 1Km @ 90 / Per Km 184 Replacement Of Out Door Yard Lights Including Wiring System And Fixing Oflamps On Fixtures. 185 Marking Of EquipmentS, Sign Boards By Way Of Painting / Fixing Of Pvc Plates For Demarcation Of Different Equipment To Avoid Mishandling. 186 Replacement / Repair / Fixing Of Ceiling Fans At Receiving Station. 187 Replacement / Repair / Fixing Of Cooling Fans On Radiators Of Power Transformer To Avoid Heating. 188 Flash In 66Kv, 33 Kv & 11 Kv Panels Due To Overloading Moisture, Cleaning Of Carbonized Panel By Petrol / Cotton Cloth, Replacement Of Damaged / Worn-Out Lugs, Post Insulator, Bakelite Sheet, Arcing Chamber Panel Heaters Etc. 189 Repair Of Plaster Of Thickness 12 Mm To 20 Mm In Patches Of Areas 2.5 Sqm Meters And Under Including Cutting The Patch In Proper Shape And Preparing And Plastering The Surface Of The Walls Complete Incl. Disposal Of Rubbish To The Dumping Ground Within 50 M Leada ) With Cement Mortar 1:4 ( 1 Cement : 4 Fine / Coarse Sand ) 190 Cutting Of Large Tree Branches Falling Over 66 / 33 Lines And Coming Into The Corridor To Avoid Damages / Faults / Conductor Snapping. 191 Cleaning Of Cable Duct, Removing Of Duct Covers And Placing Back After Cleaning The Duct Including Disposal Of Rubbish Up To 50 Mtr Lead 192 Replacing Sand Store Slabs In Roofing, Laid Incement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) Including Necessary Repairs And Cement Painting With Same Mortar Complete, Including Disposal Of Rubbish To Dumping Ground Within 50 Meters Of Lead 193 Dismantling Doors, Windows And Clerestory Windows ( Steel Or Wood ) Shutter Including Chow Khats, Holdfast Etc. Complete And Stacking With 50 Mtr Lead 194 Providing And Fixing T-Iron Frames For Doors, Windows And Ventilators Of Mild Steel T-Sections, Joints Mitred And Welded, Including Fixing Of Necessary But Hinges And Screws And Applying A Priming Coat Of Approved Steel Primer ( Cc 1:3:6 ) 195 Demolishing Cement Concrete Manually / By Mechanical Means Including Disposal Of Material Within 50 Mtr 196 Cement Concrete 1:2:4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate ) 62 Mm Thick 197 Roof Top Treatment To Prevent Water Leakage Of Control Room 198 Repairing Of Receiving Station Mesh Fencing / Chain Link Mesh Fencing Height Upto 8Ft 199 Watering Of Earth Pits 200 Cleaning Of Acdc, Dbdc Board, Rtcc, Charger, Battery Bank, Solar Batteries, Other Alike Small Equipments ( Complete Job ) 201 Cleaning Of 66 / 33 Kv Crp Using Vacuum Cleaner From Inside With Proper Care, From Outside With Thinner / Varnish And Making 66 / 33 Kv Crp Vermic Proof. 202 Cleaning Of 11 Kv Panel Using Vacuum Cleaner From Inside With Proper Care, From Outside With Thinner / Varnish And Making It Vermic Proof To Avoid Rodent Faults. 203 Erection Of Channel Cross Arm Of Size 100X50x 6Mm , 10 Feet Long And Above Including Fixing Of Ms Flat Iron Clamps With Required Size Of Bolts Including Punching Of Bolts Complete 204 Erection Of Channel Cross Arm Of Size 100X50x 6Mm Up To 09 Feet Long Including Fixing Of Ms Flat Clamps With Required Size Of Bolts Including Punching Of Bolts Complete 205 Erection Of Angle Iron Braces Of Size 65X65x6 Mm, Fixing With Double Clamp Of Ms Flat Including Punching Of Bolts Of Ist Level To Level 3Rd In Cross Section Typeabove Up To 14Longcomplete 206 Erection Of Angle Iron Braces Of Size 65X65x6 Mm Along With Belts Of Same Size , Fixing With Double Clamp Of Ms Flat Including Punching Of Bolts Of Ist Level To Level 3Rd In Cross Section Type 6 And Above Upto 10Longcomplete 207 Erection Of Angle Iron Belts Of Size 50X50x 6 Mm Along With Belts Of Same Size , Fixing With Double Clamp Of Ms Flat Including Punching Of Bolts Of Ist Level To Level 3Rd In Cross Section Type Upto 10 Long 208 Erection Of Angle Ironof Size 65X65x6 Mmfixing With Double Clamp Of Ms Flat Including Punching Of Bolts Of Ist Level To Level 3Rd In Crossection Typeabove11 Long Complete For Guardnetting. 209 Flat Iron Ties 50X6 Mm Size 1 Feet Long Along With Fixing With Cross Arms 210 Erection Of 66 Kv Disc Insulator ( Polymer Type ) With Tension Fittings Including Punching Of Locking Pinscomplete 211 Erection Of 33 Kv Disc Insulator ( Polymer Type ) With Tension Fittings Including Punching Of Locking Pinscomplete 212 Erection Of 66 Kv Pin Insulator With Pins3 Nos On Top Of Cross Arm Including Fixing Of Ms Flat Ties To Rest It On , Punching Of Base Bolt / Locking Pin Complete 213 Erection Of 33 Kv Pin Insulator With Pins3 Nos On Top Of Cross Arm Including Fixing Of Ms Flat Ties To Rest It On , Punching Of Base Bolt / Locking Pin Complete 214 Erection Of Guy Rodincluding Digging Of Pit , Disposal Of Excavated Soil , Refilling Of Excavated Pits In Layers Of Stone Boulders And Fine Soil Including Fixing , Adjusting Properly Turn Buckle, Anchor Plate And Staining Screw Complete 215 Carriage At Site , Un-Bundling , Laying And Stringing Of Acsr Dog Conductor Including Making Of Small Bundles Of Conductor As Per Site Requirement, Cutting In Required Span Lengths Complete ( As Per Rec Standard ) 216 Erection Of Anti Climbing Devices At St Pole Along With Fixing / Cutting / Bending Of Barbed Wire, Fixing With Clamps 217 Erection Of Danger Plates 218 Route / Temp Path Clearance By Way Of Cleaning Bushes And Vegetation & Making Temp. Pathcutting & Filling For Carriage Of Line Material ( 400 Mx1mx0.2M ) = 80 Cum 219 Watch And Ward Of The Material And T&P Round The Clock I.E. 3 Shifts, Rate Of 1 Lab For 1 Shift 220 Route Clearance For Corridor Of 5 M 221 Installation, Testing And Commissioning Of 11Kv Panel Board With Vcb Incomer ( One No. ) 222 Installation, Testing And Commissioning Of 11Kv Panel Board With Vcb Outgoing ( One No. ) 223 Setting Of Stubs With Templates After Positioning And Leveling Of Templates Excluding Cost Of Foundations 224 Handling And Fabrication Of Material In Divisional Store, Fabrication Of Angle Iron Braces / Belts / Guard Netting Angles, Fencing Posts Etc From Angle Iron Of Sizes 225 Fabrication Of Guy Rods Complete Including Turn Buckle, Staining Screw, Anchor Plate, Thereading Of Guys And Staining Screw 226 Fabrication Of Channel Cross Arms Of Sorts From Ms Channel Of Sizes , Making Holes As Per Requirement, Punching Of Members And Numbering On Each Member, Grinding Of Sharp Edges And Uneven Surface Of Memebers And Painting Of Members With Red Oxide Paint. 227 Fabrication Of Ties, Clampsfrom Ms Flat ( Suitable For 9 Mts, 11Mts, 13Mts & 16 Mts Poles ) 228 Fabrication Of Earthing Plates , Cable Duct Coversfrom Ms Plate As Per Rec Drawings 229 Fabrication Of Earthing Spikes From Ms Tor Steel Of Sorts As Per Rec Drawings 230 Fabrication Of St Poles By Way Of Drilling Of Extra Holes 231 Fabrication Of Foundation Boltsfrom Ms Tor Steel Of Sorts Including Threading As Per Rec Drawings 232 Fabrication Of Earthing Pipe From Gi Pipe And Welding Of Earthing Plateas Per Rec Drawings 233 Fabrication Of Column Structures, Beam Structure, Isolator Structures, La , Ct, Pt And Pi Structures As Per Rec Drawings 234 Shifting Of Channel / Angle / Flat Iron At And Average Distance Of 50Mtr From Unloading Site To Site Of Stacking And Stacked Properly. 235 Shifting Of Channel / Angle / Flat Iron / Fabricated Material At And Average Distance Of 50Mtr For Making Space For Other Store Material And Its Stacking . 236 Unloading Of Pcc Poles 9 / 8 Mts . 237 Unloading Of Pcc Poles 11 Mts . 238 Unloading Of Pcc Poles 13 Mts . 239 Dragging / Shifting Of Pcc / St Pole At And Average Istance Upto 50 Mtr For Stacking To Accesible Place For Loading / Unloading Purpose And Its Satacking 240 Shifting Of Old / New Acsr Conductor At And Average Distance Of 50Mtr For Unloading Site To Site Of Stacking And Stacked Properlyand Also For Making Space For Other Store Material And Its Stacking .. 241 Unloading Of 11Kv Vcb Pannels ( 1+3 ) 242 Unloading Of 11Kv Vcb Pannels ( 1+4 ) . 243 Unloading Of 11Kv Vcb Pannels ( 1+5 ) . 244 Unloading Of 11Kv Vcb Pannels Ok / Damaged ( 1No ) . 245 Unloading Ofac Board / Dc Board / Battery Bank / Battery Charger 246 Unloading Of 33 / 66 Kv Vcb / C&R Pannel . 247 Shifting / Draggingof 11 / 33 / 66Kv Panel At An Average Distance Of 50Mtr For Making Space For Other Store Material And Its Stacking Also For Making Space For Other Store Material And Its Stacking . 248 Unloading Of Xlpe Cable 120 / 185 Mm² . 249 Unloading Of Xlpe Cable 240 / 300 Mm² . 250 Unloading Of Xlpe Cable 400 / 630 Mm² . 251 Shifting Of Xlpe Cable All Sizes At An Average Distance Of 50Mtr From Unloading Site To Site Of Stacking And Stacked Properly Also For Making Space For Other Store Material And Its Stacking ... 252 Unloading Of 66 / 33 / 11 Kv Cable Kits Of Different Sizes 253 Shifting Of 66 / 33 / 11 Cable Kits Of All Sizes At An Average Distance Of 50Mtr From Unloading Site To Site Of Stacking And Stacked Properly Also For Making Space For Other Store Material And Its Stacking ... 254 Unloading Of Guy / Gi Wire / Barbed Wire Including Carriage Towards Stacking Site And Stacked Porperly. 255 Unloading Of 11Kv New / Damaged Distributiontransformer. 256 Dragging Of 11Kv Transformer At An Average Distance Upto 50 Mtr For Stacking To Accesible Place For Loading / Unloading Purpose And Its Satacking 257 Unloading Oftransformer Oil Barrels. 258 Dragging Oftransformer Oil Old / New Barrel At An Average Distance Upto 50 Mtr For Stacking To Accesible Place For Loading / Unloading Purpose And Its Satacking Also For Making Space For Other Store Material And Its Stacking .. 259 Unloading Ofms Angle, Ms Channel, Ms Flate , Tar Steel 260 Unloading Of Hardware Items Such As Nuts And Bolts , Clamps Of Sorts, Washers, Welding Rods, Old Sarees, Chain Link Mesh, Pipe Etc . 261 Shifting Ofhardware Items Such As Nuts And Bolts , Clamps Of Sorts, Washers, Welding Rods, Old Sarees, Chain Link Mesh, Pipe Etc At An Average Distance Of 50Mtr For Making Space For Other Store Material And Its Stacking . 262 Unloading Of 33 / 11 Kv Disc Insulators. 263 Unloading Of 33 Kv Disc Fittings 264 Shiftingof 33 / 11Kv Disc Insulator At An Average Distance Upto 50 Mtr For Stacking To Accesible Place For Loading / Unloading Purpose And Its Satackingalso For Making Space For Other Store Material And Its Stacking .. . 265 Unloading Of 33 / 11 Kv Pin Insulators / Guy Insulator / G.I Pin. 266 Shiftingof 33 / 11Kv Pin Insulator / Guy / G.I Pinsat An Average Distance Upto 50 Mtr For Stacking To Accesible Place For Loading / Unloading Purpose And Also For Making Space For Other Store Material And Its Stacking. 267 Unloading Of Cement. 268 Shiftingofcement / Cement Block At An Average Distance Upto 50 Mtr For Stacking To Accesible Place For Loading / Unloading Purpose And Also For Making Space For Other Store Material And Its Stacking ... 269 Unloading Of 33 Kv Ct / Ptunit . 270 Shifting Of 33 Kv Ct / Pt At An Average Distance Of 50Mtr For Making Space For Other Store Material And Its Stacking . 271 Unloading Of 11 Kv Ct / Ptunit Includingcarriage Towards Stacking Site And Stacked Porperly. 272 Shiftingof 11 Kv Ct / Ptat An Average Distance Upto 50 Mtr For Stacking To Accesible Place For Loading / Unloading Purpose And Also For Making Space For Other Store Material And Its Stacking .. 273 Unloading Of 33 Kv Isolators. 274 Shiftingof 33Kv Issolatorsat An Average Distance Upto 50 Mtr For Stacking To Accesible Place For Loading / Unloading Purpose And Its Satackingand Also For Making Space For Other Store Material And Its Stacking . . 275 Unloading Of 33 / 66 Kv Las. 276 Shiftingof 33 / 66Kv Lasat An Average Distance Upto 50 Mtr For Stacking To Accesible Place For Loading / Unloading Purpose And Also For Making Space For Other Store Material And Its Stacking . 277 Unloading Of 11 Kv Las / Go / Hg / Issolator . 278 Shiftingof 11 Kv Las / Go / Hg / Issolator At An Average Distance Upto 50 Mtr For Stacking To Accesible Place For Loading / Unloading Purpose And Also For Making Space For Other Store Material And Its Stacking .. 279 Unloading Of Pvc Cable / Control Cable Of Different Sizeincludingcarriage Towards Stacking Site And Stacked Porperly. 280 Unloading Of Al Paint / Red Oxide Paint / Black Paintincludingcarriage Towards Stacking Site And Stacked Porperly. 281 Unloading Of 66Kvct / Pt / Isolator . 282 Shiftingof 66 Kv Ct / Pt / Isolator At An Average Distance Upto 50 Mtr For Stacking To Accesible Place For Loading / Unloading Purpose And Also For Making Space For Other Store Material And Its Stacking .. 283 Unloading Of T&P Items Like Drilling Machine, Chainpully , Pully Lifting Machine , Hand Drill Machine, Al Ladder, Welding Set, Tool Kit, Crimping Tooletc 284 Dismantling Of Old 11Kv Isolator Including Allied Equipments 285 Installation Of 11Kv Isolators 286 Shiftingof T&P / Testing / Safetyequipments At An Average Distance Upto 50 Mtr For Stacking To Accesible Place For Loading / Unloading Purpose And Also For Making Space For Other Store Material And Its Stacking .. 287 Unloading Of Filter Plant Heavy Duty 288 Shiftingof Filter Plantat An Average Distance Upto 50 Mtr For Stacking To Accesible Place For Loading / Unloading Purpose And Also For Making Space For Other Store Material And Its Stacking . 289 Loading Of Pcc Poles 9 / 8 Mtr 290 Loading Of Pcc Poles 11 Mtr 291 Loading Of Pcc Poles 13 Mtr 292 Loading Of Cement 293 Loading Of 11 Kv Vcb 1+3 Pannels 294 Loading Of 11 Kv Vcb 1+4 Pannels 295 Loading Of 11 Kv Vcb 1+5 Pannels 296 Loading Of 11 Kv Vcb 1 Pannel Ok / Damage 297 Loading Of Ac Board / Dc Board / Battery Charger / Battery Bank 298 Loading Of 33Kv Vcb 299 Loading Of 33Kv C&R Pannels 300 Loading Of Xlpe Cable 120 / 185 Mm² 301 Loading Of Xlpe Cable 240 / 300Mm² 302 Loading Of Xlpe Cable 400 / 630 Mm² 303 Loading Of Cable Kits Of Different Sizes 304 Loading Of Guy / Gi Wire / Barber Wire 305 Loading Of 11 Kv Distributiontransformer 306 Loading Of Transformer Oil Barrels 307 Loading Of Ms Angle Iron Braces, Ms Channel Cross Arms, Guy Rod, Earthing Spikes, Ms Flate 308 Loading Of Hardware Items Such As Nuts And Bolts, Clamps Of Sorts, Washers, Welding Rods, Old Sarees, Chain Link Mesh, Pipe 309 Loading Of 33 / 11Kv Disc Insulator 310 Loading Of 33 Kv Disc Fitting 311 Loading Of 33 / 11 Kv Pin Insulator / Guy Insulator / G.I Pin 312 Loading Of 33 Kv Isolator 313 Loading Of 33 Kv La 314 Loading Of 11Kv Isolators 315 Loading Of Pvc Cable / Control Cable Of Different Size Includingcarriage From Stacked Site. 316 Loading Ofal Paint / Red Oxide Paint / Black Paint 317 Loading Of66kvct / Pt / Isolator 318 Loading Of66kvc&R Pannel 319 Loading Of66kv Vcb Breaker Sf6 320 Loading Of66kv La 321 Loading Offilter Plant Heavy Duty 322 Carriageof Fabrication Column Structures, Beam Structure, Isolator Structures, La , Ct, Pt And Pi Structures Etc Towards Stacking Site And Stacked Properly 323 Loading Offabrication Column Structures, Beam Structure, Isolator Structures, La , Ct, Pt And Pi Structures Etcincludingcarriage From Stacked Site. 324 Loading Of 33 Kv Ct / Pt Units 325 Loading Of 11 Kv Ct / Pt Units 326 Loading Of T&P Items Like Drilling Machine, Chainpully , Pully Lifting Machine , Hand Drill Machine, Al Ladder, Welding Set, Tool Kit, Crimping Tooletc Units 327 Loading Of Testing Equipments Like Meggar, Earth Resitivitytester , Oil Testing Machine, Search Light, Turn Ratio Meter , Multimeter Etc Units 328 Loading Of Safetyequipments Like Safety Belts, Safety Shoes, Fire Extinguisher, Hand Gloves, Yard Lights , Led Bulbs , Rubber Mat , Etcunits 329 Shifting Of Allied Materials For Making Space For Porper Stacking Of Material 330 Carriageof Fabrication Material From Fabrication Site Towardsstacking Site And Proper Stacking Of Material. 331 Repair Of Store Shed By Way Of Replacement Of Damaged Cgi Sheets, Repair Of Cgi Sheets By Way Of Welding, Replacememt Of Hooks, Nuts And Bolts, Tightening Of Nuts Bolts And Hooks And Welding . 332 Collection Andcarriage Of T&P Items To Working Site And Back Crriage Of T&P After Job 333 Replacement Of Damaged Glass Panes 334 Replacement Of Damaged 66 / 33Kv PiS 335 Checking / Measuring / Inspection / Meggering Ofxlpe Cable / Control Cable By Way Of Unreal And After Work Agian Rereelingon Drum 336 Checking / Measuring / Inspection Ofacsr Conductorby Way Of Unreal And After Work Agian Re-Reelingon Drum 337 Complete Testing / Inspection Of Pannels Including Relay Testing , Interconnection, Charging Polarity Etc During Issue / Receipt / Verification. 338 Prototype Erection Of Gantry / Beam / Ct / Pt / Isolator Sturcture 339 Charges For Providing Highly Skilled Electrician / Fitter / Welder / Mason / Painter 340 Charges For Providingskilled Electrician / Fitter / Welder / Mason / Painter 341 Charges For Providingunskilled Labour
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 8
Jammu And Kashmir View Result →
Contract Date: Ref. Documents Contract Value : 4.94 Lakh
Boards / Undertakings / PSU No of Bidders 4
West Bengal View Result →
21.
Defence #8519198 AOC
Tender For Provision Of Roof Top Solar Plant Totaling 250 Kw At Certain Building At Mhow Under Ge M Inf School Mhow; 1 Design, supply,installing, testing and commissioning of grid connected Solar PV plant of 50 KW AC side with 60 KWp DC side capacity to be installed on roof top including ballasted type module mounting structure, solar grade DC copper cable upto inverter, array junction boxes, MCconnectors,AC combination boxes, AC distribution board , junction / combiner boxes (including the module junction box, string junction box and main junction box equipped with appropriate functioning safety including fuses,SPD , grounding etc.) with necessary piping system, valves, foundation/staging work, as conditions for Solar Panel comprising of following sub components/sub systems and installation accessories complete including having following features complete all as specified and as directed in the technical specification of tender document and meeting the specifications as given subsequently in Annexures & as directed in scope of work and technical specification. 2 Note-(i) Items from 1(I) to 1(V) shall be considered as one item of Solar PV plant and cost of these items are deemed to be included in the above Item No.- 1.(ii) Contractor will do the site recce, shadow analysis and submit the following duly vetted by NISE/IIT/NIT/Govt Research Centre :(a) Shadow analysis report (b) Design /drawings of mould mounting structure(c) Single line diagram of strings etc.(d) IEC/ Certifications(e) Inverter Configuration(f) Layout of lightning protection/earthings (g) Grid interconnection 3 I (A) Solar PV Module(i) Solar modules not less than 500 watts each as per detail technical specifications mentioned as under: (ii) Modules should have efficiency of not less than 20% and the fill factor should be above 75% with cell and module both manufactured in INDIA. Make : Waaree / Vikram/Jackson/Emvee/Adani Solar/ Tata Power Solars Ltd/Havells/ Neosol/ Satvik Green / Rhaine Solar(DCR Modules) (iii) Voltage at Pmax - 41.98 V minimum for 144 Cells (iv) Current at Pmax - minimum 12.99A for 144 cells (v) Open circuit voltage - 49.97V minimum for 144 Cells(vi) Short cicuit current-minimum 13.74 Amps (vii) Maximum system voltage (Volts)- 1500 VDC (viii) Type of solar PV cell- Mono PERC creystalline silcon (ix) Suitability - For grid connected system (x) Module output -MC electronics plug (Male and female) (xi) Certification- The PV modules must conform to the latest edition of any of the following IEC/equivalent BIS Standards for PV module design qualification and type, approved as per IEC61215/BIS14286 (xii) In addition, the modules must conform to IEC 61730 Part 1(A1+A2+A11)-requirements for construction & Part 2(+A1)-requirements for testing, for safety qualification (xiii) The modules must conform to IEC 61701 , IEC 62716 ,62804 PID resistant (xiv) Latest STC report should be provided from any MNRE authorized test lab , report should not be 3 months old from the date of tender (xv) Application Class - A (xvi) Safety Class-A(xvii) Fire rating Class - C (xviii) All above electrical parameter measured - Standard test condition ofirradiance of 1000 W/m², AM 1.5 and cell temperature of 25° C(xix) Supply and installation of modules and installation is to be done as per the design and SLD attaches in the Technical specification (xx) Solar module shall be inspected and tested at a factory in India in the presence of an officer detailed by the Accepting Officer before despatch to the execution site. 4 (xxi) Material Warranty: (i) The contractor should warrant the Solar Module(s) to be free from the defects and / or failures specified below for a period not less than 10 (ten) years from the date of completion of work. He will obtain similar warranty from the original manufacturer and will submit the same to the GE (MIS) Mhow. However contractor will be responsible for the enforcement of warranty which shall include (a) Defects and / or failures due to manufacturing (b) Defects and / or failures due to quality of materials (c) Non conformity to specifications due to faulty manufacturing and / or inspection processes.(xxii) Performance Warranty: PV modules must be warranted by the contractor for output peak wattage, which should not be lessthan 90% at the end of 10 years and 80% at the end of 25 years. He will obtain similar warranty from the original manufacturer and will submit the same to the department. However contractor will be responsible for the enforcement of warranty. If Module(s) fail(s) to exhibit such power output in prescribed time span, thecontractor / manufacturer will be bound to either deliver additional PV Module(s) to replace themissing power output with no change in area of site used or replace the PV Module (s) without claim of no extra cost at the sole discretion of GE (MIS) Mhow. An amount as detailed in Particular Specifications here-in-after shall be held against as security deposit. 5 II) Module Mounting Structure(i) Supply and Installation and comissioningof Ballast type solar module mounting structure (ii) Material : Mild steel structure, Hot Dip Galvanised of 80 micron thick/Aluminium 6063-T6 as per ASTM, corrosion resistant. Galvanization shall conform to IS-2629, 4759 & 4736 as applicable.The fasteners shall be stainless steel to fix with the modules and with pre fabricated PCC Bricks. The contractor shall submit the design, length, section, detailed layout etc. of the structure. (iii) Minimum Module ground clearance should be 100 mm. (iv) The structure should be capable of withstanding a wind load of 180 km/hr after installation of pre fabricated PCC blocks of required size. (v) PCC blocksshould comply with IS 2185-1 (2005) (vi) The tilt angle is kept at 8-10 degree or as per site requirement , module orientation is landscape type. IS 875: Part 3 - 2015 for the design loads for Buildings and structures- Wind Loads (vii) The array structure shall be grounded properly using maintenance free earthing kit(viii)All fasteners are to be used of SS304. (ix)The mounting structures of solar PV modules, electrical works and overall workmanship of the grid solarpower plant up to inverter must be warranted for a period minimum 05 (Five) years.If all the items fails to conform to this warranty, the contractor/ manufacturer will repair or replace the items at their own expenses. 6 (III) Power Conditioning Unit (On grid Inverters) :-(i) Supply and Installation and comissioningof Solar Grid Connected inverter of capacity not less than 50 KW, 3 phase, 440 Volt, AC operated, 50 Hz,outoor typewith following features completeall as technical specis as specified and directed in the Anexure-2Make : Delta/ABB/SMA/Polycab/Huawei/Solis/ Sungrow (ii) The Power Grid should have the following salient features :- (iii) The PCU / inverters should be tested from the MNRE approved test centres / NABL / BIS / IEC accredited testing-calibration laboratories. (iv)The charge controller (if any) / MPPT units environmental testing should qualify IEC 60068-2 (1, 2, 14, 30) / Equivalent BIS standard. The junction boxes / enclosures should be IP 65 (for out door) / IP 54 (indoor) and as per IEC 529 specifications. (v) Built-in meter and data logger to monitor plant performance through external computer shall be provided.(vi) The power conditioning units / inverters should comply with applicable IEC / equivalent BIS standard for efficiency measurements and environmental tests as per standard codes IEC 61683 / IS 61683 and IEC 60068-2 (1,2,14,30) / Equivalent BIS Standard (vii) Economical requirements:- (a) Maximum efficiency >98%. (b) Opti trace MPP tracking for best MPP tracking efficiency. (c) Active temperature management with Opti cool. (d) Bluetooth communication. 7 (viii) Simple requirements:-(i) Three Phase Grid feed-in.(ii) Cable connection without tools.(iii) DC plug-in system.(A)50 KW INVERTER (1 No.):-(1) Input (DC) (i) Maximum input DC power - 66.5 KWp (ii) Maximum Input voltage- 1000V(iii) Operating voltage range - 200 V - 1000 V (v) Max. input current-40A/30A/30A(vi) No. of DC Inputs - 4/3/3 (vii)Start up Input Voltage - 350 Volts (2) Output (AC) (i) Max. Output power - 50 KW(ii) Nominal power -50 kW(iii) Maximum output Current- 80 A (iv) Nominal output Voltage-400V (v) Operating voltage range -310 Vac-480 Vac (vi) Power factor (Adjustable)-0.8 ind -0.8 Cap (vii) Output frequency-50 HZ ± 5 HZ (viii) Harmonic distortion, current < 3 %(3) Efficiency:-(i) Peak Efficiency- 98.50%, (ii) Euro Efficiency- 98.30 %,(4) Environmental limits :- (i)Degree of protection -IP65(ii) Operating temperature --20⁰ C to +50⁰ C (iii)Maximum altitudue (above sea level) - <4000m(iv) User interface and communications-LCD Display(v) Communication Port:RS 485 (vi) DC switch -DC relays (5) Protection & Monitoring:- (i) Ground fault monitoring (ii) Anti islanding (iii) Grid monitoring (iv) DC reverse polarity (v) AC and DC short circuit and over current(vi) Over current/ over voltage and over temperature 8 (IV) SOLAR DC CABLES(i) Supply laying and testing Solar DC copper cables multi stranded conductor, XLPE or XLPO insulted, IR/UV protected conforming to TUV 2 PfG 1169/08.2007 as per the technical specification mention in Annexure - 3 of size not less than 4 sqmm and maximum voltage drop shall be limited to 2%. The solar cable shall be laid for interconnecttion of PV modules, PV modules to DC DB andDC DB to inverter. Make :Polycab/ KEI/ Apar Cables/ Seichem/ Leoni Cables (ii) Shall meet IEC 60227/IS 694, IEC60502/IS 1554 standard Temp range: -10*C to +80*C Voltage rating 660/1000V (ii) Shall meet IEC 60227/IS 694, IEC60502/IS 1554 standard Temp range: -10*C to +80*C Voltage rating 660/1000V (iii) Solar cable shall be as perspecification TUV 2 PfG 1169/08.2007 (iv) Cable installation shall be as per IS 1255(v) The size of each type of DC cable selected shall be based on minimum voltage drop however; the maximum drop shall be limited to 2%. (vi) All cables and conduit pipes shall be clamped to the rooftop, walls and ceilings with thermoplastic clamps at intervals not exceeding 50 cm. The DC cable size shall be minimum of 4.0 mm2 copper,Solar cable shall be aesthetically tied to Module Mounting Stucture using UV resistant cable ties suitable for out door application. 9 (V) DC DISTRIBUTION BOARD(i) Supply andinstallation of DCDB for 50 KW plant as per the specification mention inAnnexure -4. (ii) The DC distribution box shall be of the thermos-Plastic with UL 94 for fire safety and SS fasteners IP65 DIN-rail maintaining type .(iii) DC surge protection devise (SPD), class 2 as per IEC 60364-5-53 (iv) The fuses IEC/ equivalent BIS standard should comply with applicable IEC/ equivalent BIS standard for general safety requirements for connectors, switches, circuit breakers, low-voltage switch gear as per standard codes IS/IEC 60947 (Part 1, 2 & 3), EN 50521 . (v) Number of DC SPD with specification : 1000 VDC , Up :1.9kv , Imax :40 KA , Ucpv : 585 V DC , Iscpv : 2000 A in DCDB should beEQUIVALENT TO No. of MPPTs in Inverter, number of I/P and O/P in DCDB should be equal to number of string inputs in the inverter (vi) Each string should have DC fuse with specification , I - 15 Amp , 1000 Vdc with DC fuse Holder as per specification 1000 vdc , 30 a ,100ka SCCR as per IEC 60269-2-1,60947-3 , IP 20 on its positive side Note : The number of inputs and outputs in DC DB should be equal to No. of string inputs in Inverter. 10 (VI) AC DISTRIBUTION BOARD :- Supply and installation and testing of ACDBs for 50 KWroof top solar power plant including following components:- (i) AC circuit breaker, 4-pole AC surge protection devise (SPD), class2 as per IEC 60364-5-53 ,ACSPD with specification for 3 phase and 1 neutral ,Uc :335V Ac , Up : 1.5 KV , In : 20 KA , Imax : 40 KA (ii) Each ACDB should be having MFM with Accuracy class 0.5 , panel meter compatible with RS 485 communication compatiblewith remote monitoringsystem . (iii) The panel shall be duly wired with suitable size of 1.1kV, PVC insulated cable and terminals shall be brought out for cable connections. 10% spare terminals subjected to minimum one of each rating shall be provided on each distribution switchgear. (iv) 240 V, 15 A, 3 pin industrial socket-outlet with ON/OFF switch shall be provided in each panel (v) The fuses (AC/DC) should comply with applicable IEC/ equivalent BIS standard for general safety requirements for connectors, switches, circuit breakers, low-voltage switch gear as per standard codes IS/IEC 60947(Part 1, 2 & 3), EN 50521 ,IEC 61439-1 IEC 61439 -2 (vi) IEC 62052-11 for Electricity metering equipment (A.C.) - General requirements, tests and testconditions - Part 11: Metering equipment. (a) ACDB 1 IN with 1 Out with SPD, MFM , Indiactors,Circuit Breaker ,15 Amp socket ,IP65( suitable for 50 KW AC output) (b) MCCB 4 Pole 125 Amp, 415 V, Breaking capacity -36 kA with extended rotary handle - 1 No. (vii) ESE type Lightning aresstor to protect the all the roof installed with solar moduleswith counter, mounting structure and Accessories. 5 mtr Height (As per NFC 17 102) suitable for 50 m protection radius all as specified and directed - 1 No. Make: True Power/ Erico/ JMV/ Remedies. Note : (i) Lightning protection should be provided as per IEC 6205 /IS 2309 standard.(ii) To reduce the over voltage to a safe level before it reaches the PV or other sub-system components as per NFC 17 - 102 (viii) Supply and installation of maintenace free chemical earthing using electrode of size 50mm bore x 3 m longcopper bonded and connected with 25X4mm GI strip complete with excavation, earth work, cast iron cover with back fill compound (Chemical/ Back fill compound gel for earthing enhancement -50Kg) complete as specified and directed. - 4 SetsMake : Erico/ Remedies Earthing System/True Power or equivalent Note: (i) IR Value should be less than 1.(ii) Copper stip of size 32mmX6mm including installation 7.5 m (Copper purity not less than 99%) 11 (a) The photovoltaic modules, BOS and other components of power plant requires adequateearthing for protecting against any serious faults as guided by IEC 60364. (b) Each set of chemical earthing to be provided for PV modules & MMS, PCU/Inverter & DCDB, ACDB and Lightning arrestor separately with GI strip of size of 25 x 4 mm. (c) The earthing system shall be designed, in accordance with IS: 3043-1987 and IEEE 80, IndianElectricity Rules, Codes of practice and regulations(IX) M&L for earth continuity conductor or main GI earthing strip 25x4 mm fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required galvanised complete all as specified and directed. (X) Supply, laying andtesting XLPE insulated, PVC sheathed single or multi-core flexible copper conductor cable of size 3.5 core 35 sqmm with UV-stabilized outer sheath ,650/100 volts conforming toIS 7098 part - 1/1988 from Inverter to ACDB. Notes : (i) All cable/wires are to be routed in a GI cabletray and suitably tagged and marked with proper manner by good quality ferule or by other means so that the cable easily identified. Solar cables shall be aesthetically tied to Module Mounting Structure using UV resistant cable-ties suitable for outdoor application. (ii) The total voltage drops on the cable segments from the solar grid inverter to the building distribution board shall not exceed 3.0%(XI) Supply, laying andtesting XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 3.5 core 50 sq. mm (from 50 KW ACDB to LT panel) fixing with suitable clamps on floors/ walls/ roof top all as specified and directed. (XII) Supply and Installation of CPVC pipe as per IS 15778,ASTM D1784, ASTM D2846 specification and standards with water outlet at every 5 meter of Solar module cleaning system , CPVC pipe with 50 mm diawater piping laid through out the solar module array installation with 40 mm outlet fitted with long handle ball valve, one UNION at every 20 running meter to be fitted for easy service and installation complete all as specified and directed.Note : Cleaning of solar panels is required twice a week. 12 Design, supply, installing, testing and commissioning of grid connected Solar PV plant of 40 KW AC side with 48 KWp DC side capacityto be installed on roof topincluding ballasted type module mounting structure, solar grade DC copper cable upto inverter, array junction boxes, MCconnectors,AC combination boxes, AC distribution board , junction / combiner boxes (including the module junction box, string junction box and main junction box equipped with appropriate functioning safety including fuses,SPD , grounding etc.) with necessary piping system, valves, foundation/staging work, as conditions for Solar Panel comprising of following sub components/sub systems and installation accessories complete including having following features complete all as specified and as directed in the technical specification of tender document and meeting the specifications as given subsequently in Annexures & as directed in scope of work and technical specification. 13 Note- (i) Items from 2(I) to 2 (XII) shall be considered as one item of Solar PV plant and cost of these items are deemed to be included in the above Item No.- 2. (ii) Contractor will do the site recce, shadow analysis and submit the following duly vetted by NISE/IIT/NIT/Govt Research Centre :(a) Shadow analysis report(b) Design/drawing of module mounting structure(c) Single line diagrm of strings etc.(d) IEC/BIS Certifications(e) Inverter Configuration (f) Layout of lightning protection/earthings(g) Grid interconnection 14 (I) (A) Solar PV Module : (i) Solar modules not less than 500 watts each as per detail technical specifications mentioned as under:(ii) Modules should have efficiency of not less than 20% and the fill factor should be above 75% with cell and module both manufactured in INDIA. Make : Waaree / Vikram/Jackson/Emvee/Adani Solar/ Tata Power Solars Ltd/Havells/ Neosol/ Satvik Green / Rhaine Solar or equivalent (DCR Modules)(iii) Voltage at Pmax - 41.98 V minimum for144 Cells (iv) Current at Pmax - minimum 12.99A for 144 cells (v) Open circuit voltage - 49.97 V minimum for 144 Cells(vi) Short cicuit current-minimum 13.74 Amps (vii) Maximum system voltage (Volts)- 1500 VDC(viii) Type of solar PV cell- Mono PERC crystalline sillicon (ix) Suitability - For grid connected system(x) Module output -MC electronics plug (Male and female) (xi) Certification- The PV modules must conform to the latest edition of any of the following IEC/equivalent BIS Standards for PV module design qualification and type, approved as per IEC61215/BIS14286 (xii) In addition, the modules must conform to IEC 61730 Part 1(A1+A2+A11)-requirements for construction & Part 2(+A1)-requirements for testing, for safety qualification (xiii) The modules must conform to IEC 61701 , IEC 62716 ,62804 PID resistant(xiv) Latest STC report should be provided from any MNRE authorized test lab , report should not be 3 months old from the date of tender (xv) Application Class - A (xvi) Safety Class-A (xvii) Fire rating Class - C (xviii) All above electrical parameter measured - Standard test condition ofirradiance of 1000 W/m², AM 1.5 and cell temperature of 25° C(xix) Supply and installation of modules and installation is to be done as per the design and SLD attaches in the Technical specification (xx) Solar module shall be inspected and tested at a factory in India in the presence of an officer detailed by the Accepting Officer before despatch to the execution site 15 (xx) Solar module shall be inspected and tested at a factory in India in the presence of an officer detailed by the Accepting Officer before despatch to the execution site. (xxi) Material Warranty:(i) The contractor should warrant the Solar Module(s) to be free from the defects and / or failures specified below for a period not less than 10 (ten) years from the date of completion of work. He will obtain similar warranty from the original manufacturer and will submit the same to the GE (MIS) Mhow. However contractor will be responsible for the enforcement of warranty which shall include (a) Defects and / or failures due to manufacturing (b) Defects and / or failures due to quality of materials (c) Non conformity to specifications due to faulty manufacturing and / or inspection processes. (xxii) Performance Warranty: PV modules must be warranted by the contractor for output peak wattage, which should not be lessthan 90% at the end of 10 years and 80% at the end of 25 years. He will obtain similar warranty from the original manufacturer and will submit the same to the department. However contractor will be responsible for the enforcement of warranty. If Module(s) fail(s) to exhibit such power output in prescribed time span, thecontractor / manufacturer will be bound to either deliver additional PV Module(s) to replace themissing power output with no change in area of site used or replace the PV Module(s) without claim of no extra cost at the sole discretion of GE (MIS) Mhow. An amount as detailed in Particular Specifications here-in-after shall be held against as security deposit. 16 II) Module Mounting Structure(i) Supply and Installation and comissioningof Ballast type solar module mounting structure Make : Jackson/Ganges International (ii) Material : Mild steel structure, Hot Dip Galvanised of 80 micron thick/ Aluminium 6063-T6 as per ASTM, corrosion resistant. Galvanization shall conform to IS-2629, 4759 & 4736 as applicable.The fasteners shall be stainless steel to fix with the modules and with pre fabricated PCC Bricks. The contractor shall submit the design, length, section, detailed layout etc. of the structure.(iii) Minimum Module ground clearance should be 300 mm.(iv) The structure should be capable of withstanding a wind load of 180 km/hr after installation of pre fabricated PCC blocks of required size.(v) PCC blocksshould comply with IS 2185-1 (2005).(vi) The tilt angle is kept at 12 degree , module orientation is landscape type. IS 875: Part 3 - 2015 for the design loads for Buildings and structures- Wind Loads.(vii) The array structure shall be grounded properly using maintenance free earthing kit.(viii) All fasteners are to be used of SS304. (ix) The mounting structures of solar PV modules, electrical works and overall workmanship of the grid solarpower plant up to inverter must be warranted for a period minimum 05 (Five) years as detailed in Particular Specifications.If all the items fails to conform to this warranty, the contractor/ manufacturer will repair or replace the items at their own expenses. 17 III) Power Conditioning Unit (On grid Inverters):- (i) Supply and Installation and comissioningof Solar Grid Connected inverter of capacity not less than 40 KW, 3 phase, 440 Volt, AC operated, 50 Hz,outoor typewith following features completeall as technical specis as specified and directed in the Anexure-2Make : Delta/ABB/SMA/Polycab/Huawei/Havells/ Solis/ Sungrow or equivalent. (ii) The Power Grid should have the following salient features:- (iii) The PCU / inverters should be tested from the MNRE approved test centres / NABL / BIS / IEC accredited testing-calibration laboratories.(iv)The charge controller (if any) / MPPT units environmental testing should qualify IEC 60068-2 (1, 2, 14, 30) / Equivalent BIS standard. The junction boxes / enclosures should be IP 65 (for out door) / IP 54 (indoor) and as per IEC 529 specifications.(v) Built-in meter and data logger to monitor plant performance through external computer shall be provided.(vi) The power conditioning units / inverters should comply with applicable IEC / equivalent BIS standard for efficiency measurements and environmental tests as per standard codes IEC 61683 / IS 61683 and IEC 60068-2 (1,2,14,30) / Equivalent BIS Standard. (vii) Economical requirements:- (i) Maximum efficiency >98%. (ii) Opti trace MPP tracking for best MPP tracking efficiency.(iii) Active temperature management with Opti cool. (iv) Bluetooth communication. (viii) Simple requirements:-(i) Three Phase Grid feed-in.(ii) Cable connection without tools.(iii) DC plug-in system.(A)40 KW INVERTER (1 No.):-(1) Input (DC) (i) Maximum input DC power - 60 KWp (ii) Maximum Input voltage- 1100V(iii) Operating voltage range - 180 V - 1000 V (v) Max. input current-40A/40A/40A(vi) No. of DC Inputs - 8 (vii)Start up Input Voltage - 200 Volts (2) Output (AC) (i) Max. Output power - 40 KW(ii) Nominal power -40 kW(iii) Maximum output Current- 66 A (iv) Nominal output Voltage-400V (v) Operating voltage range -310 Vac-480 Vac (vi) Power factor (Adjustable)-0.8 ind -0.8 Cap (vii) Output frequency-50 HZ ± 5 HZ (viii) Harmonic distortion, current < 3 %(3) Efficiency:-(i) Peak Efficiency- 98.80%, (ii) Euro Efficiency- 98.20 %, 18 IV) SOLAR DC CABLES (i) Supply laying and testing Solar DC copper cables multi stranded conductor, XLPE or XLPO insulted, IR/UV protected conforming to TUV 2 PfG 1169/08.2007 as per the technical specification mention in Annexure - 3 of size not less than 4 sqmm and maximum voltage drop shall be limited to 2%. The solar cable shall be laid for interconnecttion of PV modules, PV modules to DC DB andDC DB to inverter. Make :Polycab/ KEI/ Apar Cables/ Seichem/ Leoni Cables. (ii) Shall meet IEC 60227/IS 694, IEC60502/IS 1554 standard Temp range: -10*C to +80*C Voltage rating 660/1000V. (iii) Solar cable shall be as perspecification TUV 2 PfG 1169/08.2007.(iv) Cable installation shall be as per IS 1255. (v) The size of each type of DC cable selected shall be based on minimum voltage drop however; the maximum drop shall be limited to 2%. (vi) All cables and conduit pipes shall be clamped to the rooftop, walls and ceilings with thermoplastic clamps at intervals not exceeding 50 cm. The DC cable size shall be minimum of 4.0 mm2 copper,Solar cable shall be aesthetically tied to Module Mounting Stucture using UV resistant cable ties suitable for out door application.(V) DC DISTRIBUTION BOARD (i) Supply andinstallation of DCDB for 40 KW plant as per the specifications mentioned below: (ii) The DC distribution box shall be of the thermos-Plastic with UL 94 for fire safety and SS fasteners IP65 DIN-rail maintaining type . (iii) DC surge protection devise (SPD), class 2 as per IEC 60364-5-53. (iv) The fuses IEC/ equivalent BIS standard should comply with applicable IEC/ equivalent BIS standard for general safety requirements for connectors, switches, circuit breakers, low-voltage switch gear as per standard codes IS/IEC 60947 (Part 1, 2 & 3), EN 50521 . (v) Number of DC SPD with specification : 1000 VDC , Up :1.9kv , Imax :40 KA , Ucpv : 585 V DC , Iscpv : 2000 A in DCDB should beEQUIVALENT TO No. of MPPTs in Inverter, number of I/P and O/P in DCDB should be equal to number of string inputs in the inverter (vi) Each string should have DC fuse with specification , I - 15 Amp , 1000 Vdc with DC fuse Holder as per specification 1000 vdc , 30 a ,100ka SCCR as per IEC 60269-2-1,60947-3 , IP 20 on its positive sideNote : The number of inputs and outputs in DC DB should be equal to No. of string inputs in Inverter. 19 VI) AC DISTRIBUTION BOARDSupply and installation and testing of ACDBs for 30 KWroof top solar power plant including following components: (i) AC circuit breaker, 4-pole AC surge protection devise (SPD), class2 as per IEC 60364-5-53 ,ACSPD with specification for 3 phase and 1 neutral ,Uc :335V Ac , Up : 1.5 KV , In : 20 KA , Imax : 40 KA (ii) Each ACDB should be having MFM with Accuracy class 0.5 , panel meter compatible with RS 485 communication compatiblewith remote monitoringsystem .(iii) The panel shall be duly wired with suitable size of 1.1kV, PVC insulated cable and terminals shall be brought out for cable connections. 10% spare terminals subjected to minimum one of each rating shall be provided on each distribution switchgear. (iv) 240 V, 15 A, 3 pin industrial socket-outlet with ON/OFF switch shall be provided in each panel (v) The fuses (AC/DC) should comply with applicable IEC/ equivalent BIS standard for general safety requirements for connectors, switches, circuit breakers, low-voltage switch gear as per standard codes IS/IEC 60947(Part 1, 2 & 3), EN 50521 ,IEC 61439-1 IEC 61439 -2(vi) IEC 62052-11 for Electricity metering equipment (A.C.) - General requirements, tests and testconditions - Part 11: Metering equipment. (a) ACDB 1 IN with 1 OUTwith SPD, MFM , Indiactors,Circuit Breaker ,15 Amp socket ,IP65( suitable for 40 KW AC output) (b) MCCB 4 Pole 100 Amp, 415 V, Breaking capacity -36 kA with extended rotary handle - 1 No. (VII) ESE type Lightning aresstor to protect the all the roof installed with solar moduleswith counter, mounting structure and Accessories. 5 mtr Height (As per NFC 17 102) suitable for 50 m protection radius all as specified and directed - 1 No.Make: True Power/ Erico/ JMV/ Remedies. Note : (i) Lightning protection should be provided as per IEC 6205 /IS 2309 standard. (ii) To reduce the over voltage to a safe level before it reaches the PV or other sub-system components as per NFC 17 - 102 20 (VIII) Supply and installation of maintenace free chemical earthing using electrode of size 50mm bore x 3 m longcopper bonded and connected with 25X4mm GI strip complete with excavation, earth work, cast iron cover with back fill compound (Chemical/ Back fill compound gel for earthing enhancement -50Kg) complete as specified and directed. - 4SetsMake : Erico/ Remedies Earthing System/True Power or equivalent Note: (i) IR Value should be less than 1.(ii) Copper stip of size 32mmX6mm including installation 7.5 m (Copper purity not less than 99%) .The photovoltaic modules, BOS and other components of power plant requires adequateearthing for protecting against any serious faults as guided by IEC 60364. (ii) Each set of chemical earthing to be provided for PV modules & MMS, PCU/Inverter & DCDB, ACDB and Lightning arrestor separately with GI strip of size of 25 x 4 mm.”.The earthing system shall be designed, in accordance with IS: 3043-1987 and IEEE 80, IndianElectricity Rules, Codes of practice and regulations(IX) M&L for earth continuity conductor or main GI earthing strip 25x4 mm fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required galvanised complete all as specified and directed. (X) Supply, laying andtesting XLPE insulated, PVC sheathed single or multi-core flexible copper conductor cable of size 4 core 25 sqmm (from inverter to ACDB) with UV-stabilized outer sheath ,650/100 volts conforming toIS 7098 part - 1/1988 of following sizes : Notes : (i) All cable/wires are to be routed in a GI cabletray and suitably tagged and marked with proper manner by good quality ferule or by other means so that the cable easily identified. Solar cables shall be aesthetically tied to Module Mounting Structure using UV resistant cable-ties suitable for outdoor application.(ii) The total voltage drops on the cable segments from the solar grid inverter to the building distribution board shall not exceed 3.0%(XI) Supply, laying andtesting XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 3.5 core 50 sq. mm (from 40 KW ACDB to LT panel) fixing with suitable clamps on floors/ walls/ roof top all as specified and directed. (XII) Supply and Installation of CPVC pipe as per IS 15778,ASTM D1784, ASTM D2846 specification and standards with water outlet at every 5 meter of Solar module cleaning system , CPVC pipe with 50 mm diawater piping laid through out the solar module array installation with 40 mm outlet fitted with long handle ball valve, one UNION at every 20 running meter to be fitted for easy service and installation complete all as specified and directed.Note : Cleaning of solar panels is required twice a week. 21 Design,supply,installing, testing and commissioning of grid connected Solar PV plant of 30 KW AC side with 36 KWp DC side capacityto be installed on roof topincluding ballasted type module mounting structure, solar grade DC copper cable upto inverter, array junction boxes, MCconnectors,AC combination boxes, AC distribution board , junction / combiner boxes (including the module junction box, string junction box and main junction box equipped with appropriate functioning safety including fuses,SPD , grounding etc.) with necessary foundation/staging work, as conditions for Solar Panel comprising of following sub components/sub systems and installation accessories complete including having following features complete all as specified and as directed in scope of work and Particular specification. 22 Note- (i) Items from 3(I) to 3(XII) shall be considered as one item of Solar PV plant and cost of these items are deemed to be included in the above Item No.- 3. (ii) Contractor will do the site recce, shadow analysis and submit the following duly vetted by NISE/IIT/NIT/Govt Research Centre :(a) Shadow analysis report(b) Design/drawing of module mounting structure(c) Single line diagrm of strings etc.(d) IEC/BIS Certifications(e) Inverter Configuration (f) Layout of lightning protection/earthings(g) Grid interconnection 23 (A) Solar PV Module : (i) Solar modules not less than 500 watts each as per detail technical specifications mentioned as under:(ii) Modules should have efficiency of not less than 20% and the fill factor should be above 75% with cell and module both manufactured in INDIA. Make : Waaree / Vikram/Jackson/Emvee/Adani Solar/ Tata Power Solars Ltd/Havells/ Neosol/ Satvik Green / Rhaine Solar or equivalent (DCR Modules)(iii) Voltage at Pmax - 41.98 V minimum for144 Cells (iv) Current at Pmax - minimum 12.99A for 144 cells (v) Open circuit voltage - 49.97 V minimum for 144 Cells(vi)Short cicuit current-minimum 13.74 Amps (vii) Maximum system voltage (Volts)- 1500 VDC (viii) Type of solar PV cell- Mono PERC crystalline sillicon (ix) Suitability - For grid connected system(x) Module output -MC electronics plug (Male and female) (xi) Certification- The PV modules must conform to the latest edition of any of the following IEC/equivalent BIS Standards for PV module design qualification and type, approved as per IEC61215/BIS14286 (xii) In addition, the modules must conform to IEC 61730 Part 1(A1+A2+A11)-requirements for construction & Part 2(+A1)-requirements for testing, for safety qualification (xiii) The modules must conform to IEC 61701 , IEC 62716 ,62804 PID resistant(xiv) Latest STC report should be provided from any MNRE authorized test lab , report should not be 3 months old from the date of tender (xv) Application Class - A (xvi) Safety Class-A (xvii) Fire rating Class - C (xviii) All above electrical parameter measured - Standard test condition ofirradiance of 1000 W/m², AM 1.5 and cell temperature of 25° C(xix) Supply and installation of modules and installation is to be done as per the design and SLD attaches in the Technical specification (xx) Solar module shall be inspected and tested at a factory in India in the presence of an officer detailed by the Accepting Officer before despatch to the execution site. 24 (xxi) Material Warranty:(i) The contractor should warrant the Solar Module(s) to be free from the defects and / or failures specified below for a period not less than 10 (ten) years from the date of completion of work. He will obtain similar warranty from the original manufacturer and will submit the same to the GE (MIS) Mhow. However contractor will be responsible for the enforcement of warranty which shall include (a) Defects and / or failures due to manufacturing (b) Defects and / or failures due to quality of materials (c) Non conformity to specifications due to faulty manufacturing and / or inspection processes.(xxii) Performance Warranty: PV modules must be warranted by the contractor for output peak wattage, which should not be lessthan 90% at the end of 10 years and 80% at the end of 25 years. He will obtain similar warranty from the original manufacturer and will submit the same to the department. However contractor will be responsible for the enforcement of warranty. If Module(s) fail(s) to exhibit such power output in prescribed time span, thecontractor / manufacturer will be bound to either deliver additional PV Module(s) to replace themissing power output with no change in area of site used or replace the PV Module(s) without claim of no extra cost at the sole discretion of GE (MIS) Mhow. An amount as detailed in Particular Specifications here-in-after shall be held against as security deposit. 25 (II) Module Mounting Structure (i) Supply and Installation and comissioningof Ballast type solar module mounting structure Make : Jackson/Ganges International (ii) Material : Mild steel structure, Hot Dip Galvanised of 80 micron thick/ Aluminium 6063-T6 as per ASTM, corrosion resistant. Galvanization shall conform to IS-2629, 4759 & 4736 as applicable.The fasteners shall be stainless steel to fix with the modules and with pre fabricated PCC Bricks. The contractor shall submit the design, length, section, detailed layout etc. of the structure. (iii) Minimum Module ground clearance should be 300 mm.(iv) The structure should be capable of withstanding a wind load of 180 km/hr after installation of pre fabricated PCC blocks of required size. (v) PCC blocksshould comply with IS 2185-1 (2005)(vi) The tilt angle is kept at 12 degree , module orientation is landscape type. IS 875: Part 3 - 2015 for the design loads for Buildings and structures- Wind Loads (vii) The array structure shall be grounded properly using maintenance free earthing kit (viii) All fasteners are to be used of SS304. (ix) The mounting structures of solar PV modules, electrical works and overall workmanship of the grid solarpower plant up to inverter must be warranted for a period minimum 05 (Five) years as detailed in Particular Specifications.If all the items fails to conform to this warranty, the contractor/ manufacturer will repair or replace the items at their own expenses. 26 (III) Power Conditioning Unit (On grid Inverters) :-(i) Supply and Installation and comissioningof Solar Grid Connected inverter of capacity not less than 30 KW, 3 phase, 440 Volt, AC operated, 50 Hz,outoor typewith following features completeall as technical specis as specified and directed in the Anexure-2Make : Delta/ABB/SMA/Polycab/Huawei/Havells/ Solis/ Sungrow or equivalent (ii)The Power Grid should have the following salient features:-(iii) The PCU / inverters should be tested from the MNRE approved test centres / NABL / BIS / IEC accredited testing-calibration laboratories. (iv)The charge controller (if any) / MPPT units environmental testing should qualify IEC 60068-2 (1, 2, 14, 30) / Equivalent BIS standard. The junction boxes / enclosures should be IP 65 (for out door) / IP 54 (indoor) and as per IEC 529 specifications. (v) Built-in meter and data logger to monitor plant performance through external computer shall be provided.(vi) The power conditioning units / inverters should comply with applicable IEC / equivalent BIS standard for efficiency measurements and environmental tests as per standard codes IEC 61683 / IS 61683 and IEC 60068-2 (1,2,14,30) / Equivalent BIS Standard 27 (vii) Economical requirements:- (i) Maximum efficiency >98%.(ii) Opti trace MPP tracking for best MPP tracking efficiency. (iii) Active temperature management with Opti cool. (iv) Bluetooth communication. (viii) Simple requirements:-(i) Three Phase Grid feed-in.(ii) Cable connection without tools.(iii) DC plug-in system.(A)30 KW INVERTER (1 No.):-(1) Input (DC) (i) Maximum input DC power - 45 KWp (ii) Maximum Input voltage- 1100V(iii) Operating voltage range - 180 V - 1000 V (v) Max. input current-40A/40A/40A(vi) No. of DC Inputs - 6 (vii)Start up Input Voltage - 200 Volts (2) Output (AC) (i) Max. Output power – 34 VA(ii) Nominal power -30 KW(iii) Maximum output Current- 51.5 A (iv) Nominal output Voltage-400V (v) Operating voltage range -310 Vac-480 Vac (vi) Power factor (Adjustable)-0.8 ind -0.8 Cap (vii) Output frequency-50 HZ ± 5 HZ (viii) Harmonic distortion, current < 3 %(3) Efficiency:-(i) Peak Efficiency- 98.60%, (ii) Euro Efficiency- 98.20 %, 28 (IV) SOLAR DC CABLES(i) Supply laying and testing Solar DC copper cables multi stranded conductor, XLPE or XLPO insulted, IR/UV protected conforming to TUV 2 PfG 1169/08.2007 as per the technical specification mention in Annexure - 3 of size not less than 4 sqmm and maximum voltage drop shall be limited to 2%. The solar cable shall be laid for interconnecttion of PV modules, PV modules to DC DB andDC DB to inverter. Make :Polycab/ KEI/ Apar Cables/ Seichem/ Leoni Cables (ii) Shall meet IEC 60227/IS 694, IEC60502/IS 1554 standard Temp range: -10*C to +80*C Voltage rating 660/1000V (iii) Solar cable shall be as perspecification TUV 2 PfG 1169/08.2007 (iv) Cable installation shall be as per IS 1255 (v) The size of each type of DC cable selected shall be based on minimum voltage drop however; the maximum drop shall be limited to 2%.(vi) All cables and conduit pipes shall be clamped to the rooftop, walls and ceilings with thermoplastic clamps at intervals not exceeding 50 cm. The DC cable size shall be minimum of 4.0 mm2 copper,Solar cable shall be aesthetically tied to Module Mounting Stucture using UV resistant cable ties suitable for out door application. 29 (V) DC DISTRIBUTION BOARD(i) Supply andinstallation of DCDB for 30 KW plant as per the specification mention inAnnexure -4. (ii) The DC distribution box shall be of the thermos-Plastic with UL 94 for fire safety and SS fasteners IP65 DIN-rail maintaining type .(iii) DC surge protection devise (SPD), class 2 as per IEC 60364-5-53 (iv) The fuses IEC/ equivalent BIS standard should comply with applicable IEC/ equivalent BIS standard for general safety requirements for connectors, switches, circuit breakers, low-voltage switch gear as per standard codes IS/IEC 60947 (Part 1, 2 & 3), EN 50521 . (v) Number of DC SPD with specification : 1000 VDC , Up :1.9kv , Imax :40 KA , Ucpv : 585 V DC , Iscpv : 2000 A in DCDB should beEQUIVALENT TO No. of MPPTs in Inverter, number of I/P and O/P in DCDB should be equal to number of string inputs in the inverter (vi) Each string should have DC fuse with specification , I - 15 Amp , 1000 Vdc with DC fuse Holder as per specification 1000 vdc , 30 a ,100ka SCCR as per IEC 60269-2-1,60947-3 , IP 20 on its positive side . Note : The number of inputs and outputs in DC DB should be equal to No. of string inputs in Inverter. 30 (VI) AC DISTRIBUTION BOARD :- Supply and installation and testing of ACDBs for 30 KWroof top solar power plant including following components:- (i) AC circuit breaker, 4-pole AC surge protection devise (SPD), class2 as per IEC 60364-5-53 ,ACSPD with specification for 3 phase and 1 neutral ,Uc :335V Ac , Up : 1.5 KV , In : 20 KA , Imax : 40 KA (ii) Each ACDB should be having MFM with Accuracy class 0.5 , panel meter compatible with RS 485 communication compatiblewith remote monitoringsystem . (iii) The panel shall be duly wired with suitable size of 1.1kV, PVC insulated cable and terminals shall be brought out for cable connections. 10% spare terminals subjected to minimum one of each rating shall be provided on each distribution switchgear. (iv) 240 V, 15 A, 3 pin industrial socket-outlet with ON/OFF switch shall be provided in each panel (v)The fuses (AC/DC) should comply with applicable IEC/ equivalent BIS standard for general safety requirements for connectors, switches, circuit breakers, low-voltage switch gear as per standard codes IS/IEC 60947(Part 1, 2 & 3), EN 50521 ,IEC 61439-1 IEC 61439 -2 (vi)IEC 62052-11 for Electricity metering equipment (A.C.) - General requirements, tests and testconditions - Part 11: Metering equipment. (a) ACDB 1 IN with 1 OUT with SPD, MFM , Indiactors,Circuit Breaker ,15 Amp socket ,IP65(suitable for 30 KW AC output) (b) MCCB 4 Pole 63 Amp, 415 V, Breaking capacity -36 kA with extended rotary handle - 1 No. 31 (VII) ESE type Lightning aresstor to protect the all the roof installed with solar moduleswith counter, mounting structure and Accessories. 5 mtr Height (As per NFC 17 102) suitable for 50 m protection radius all as specified and directed - 1 No.Make: True Power/ Erico/ JMV/ Remedies.Note : (i) Lightning protection should be provided as per IEC 6205 /IS 2309 standard.(ii) To reduce the over voltage to a safe level before it reaches the PV or other sub-system components as per NFC 17 - 102 32 (VIII) Supply and installation of maintenace free chemical earthing using electrode of size 50mm bore x 3 m longcopper bonded and connected with 25X4mm GI strip complete with excavation, earth work, cast iron cover with back fill compound (Chemical/ Back fill compound gel for earthing enhancement -50Kg) complete as specified and directed. - 3 SetsMake : Erico/ Remedies Earthing System/True Power or equivalent Note: (i) IR Value should be less than 1.(ii) Copper stip of size 32mmX6mm including installation 7.5 m (Copper purity not less than 99%) (a)The photovoltaic modules, BOS and other components of power plant requires adequateearthing for protecting against any serious faults as guided by IEC 60364. (b) Each set of chemical earthing to be provided for PV modules & MMS, PCU/Inverter & DCDB, ACDB and Lightning arrestor separately with GI strip of size of 25 x 4 mm. (c) The earthing system shall be designed, in accordance with IS: 3043-1987 and IEEE 80, IndianElectricity Rules, Codes of practice and regulations 33 (IX) M&L for earth continuity conductor or main GI earthing strip 25x4 mm fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required galvanised complete all as specified and directed. 34 (X) Supply, laying andtesting XLPE insulated, PVC sheathed single or multi-core flexible copper conductor cable of size 4 core 16 sqmm (From inverter to ACDB) with UV-stabilized outer sheath ,650/100 volts conforming toIS 7098 part - 1/1988 of following sizes : Notes : (i) All cable/wires are to be routed in a GI cabletray and suitably tagged and marked with proper manner by good quality ferule or by other means so that the cable easily identified. Solar cables shall be aesthetically tied to Module Mounting Structure using UV resistant cable-ties suitable for outdoor application.(ii) The total voltage drops on the cable segments from the solar grid inverter to the building distribution board shall not exceed 3.0% 35 (XI) Supply, laying andtesting XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 3.5 core 50 sq. mm (from 50 KW ACDB to LT panel) fixing with suitable clamps on floors/ walls/ roof top all as specified and directed.(XII) Supply and Installation of CPVC pipe as per IS 15778,ASTM D1784, ASTM D2846 specification and standards with water outlet at every 5 meter of Solar module cleaning system , CPVC pipe with 50 mm diawater piping laid through out the solar module array installation with 40 mm outlet fitted with long handle ball valve, one UNION at every 20 running meter to be fitted for easy service and installation complete all as specified and directed.Note : Cleaning of solar panels is required twice a week. 36 Note for Item No. 1,2 & 3:-1.Monthly visit by technician for regular maintenance inclusive ofincluding cleaning of solar panels, periodical checks and maintenance as recommended by OEM including ensuring serviceability of the plant i.e. solar panels, inverters, DCDB, ACDB etc. including submittingmonthly/quarterly power generation reports to the department and other maintenance schedules as per OEM of monthly, quarterly, half-yearly and yearly basis and to monitor the system efficacy and attending any complaint on call within 48 hours is deemed to be included in the cost of Item No.-1 for which scope is as under:2. Repair/replacement of solar modules, mechanical structure of solar module, electrical work and overall workmanship of grid solar power plant upto inverter is already covered under material and performance warranty3. The contractor shall be responsible for approval from MPEB for electrical parameters after connection with grid.4. The thermal imaging of PV Panelsshould be taken once a year for checking its health including hot spots.5. The shut down duration of Inverter should be monitored and recorded and analyzed.6. Maintaining the visit and event logbook.A note of any event that has occurred due to which the Solar system has underperformed or had stopped shall be made in the log book.The corrective action taken and equipment or parts replaced as authorised by MES shall also be noted in the event book. (i) Solar Panel MaintenanceThe Solar array (a number of solar panels connected together) is often thought to be maintenance free.However, occasional maintenance i.e once in fortnight and inspection of the solar array must be performed to ensure the optimal use of the solar panels.This can be done by keeping the surface (glass) area of the module clean from any excess dirt. Each panel shallbe washed, cleaned with water and sponge properly fortnightly.If the module has thick dirt or grime and bird droppings, which are harder to remove with plain water and sponge then washing soap / other chemical as per OEM guidelines shall be used. 37 (ii) Notes 1. Metal brush will not be used to clean solar panel surface.2. A visual inspection of the modules will also be done during cleaningto check for defects in the modules such as cracks, chips, de-lamination, fogged glazing, water leaks and discoloration.If any obvious defects are found,the location shall be noted in the system logbook, so that they can be monitored in the future in case further deterioration affects the modules output.3. The condition of the array mounting frame will also be checked by supervisor cum tradesman. Items to observe shall include the array mounting bolts (e.g.bolt rusting) andensure that the frame and modules are firmly secured.The junction boxes shall also be checked to ensure that the wires are not chewed by rodents or insects.(iii) Wiring and connectionsWiring installations shall be checked for any cracks, breaks or deterioration in the insulation/conduits.Inspect panel boxes to ensure that they have not become a home for rodents and insects.Also inspect connections for any corrosion and/or burning.Switches should not spark when turned on or off.The following sections of conduit and wiring should be checked for any signs of damage:-Solar panels to the DCDB, DCDB to the Inverter, Inverter to the ACDB, If any damage is found, the same shall be repaired/replaced .All ground wires shall be checked to ensure that they are not broken.Note : (i) Contractor shall submit the shadow analysis of roofs considered, design/ drawings of roof top solar including all components to the accepting officer duly vetted by NISE/IIT/NIT.(ii)Contractor shall submit the technical details, IEC certificates of PV modules, inverter, DCDB/ACDB.(iii)Design structural drawings of module mounting structure alongwith design calculations shall be submited by the contractor duly vetted from NIT / IIT / Govt Research Institute. The cost of same shall be deemed to be included in this item
Contract Date: Dec 30, 2025 Contract Value : 1.27 Crore
Statutory Bodies & Commissions/Committees No of Bidders 6
Madhya Pradesh View Result →
22.
Public Administrative Department #8485802 AOC
Up-Gradation Of Safety Works At Bmc Headquarters, Mumbai-5MP AI Dome CameraImage Sensor: 1/2.8 Sony CMOS progressive sensor | Day/Night Operation: Yes with IR Cut Filter | Minimum Illumination: Color: 0.5 lux; B/W 0 Lux with IR | Lens: 2.7~13.5mm ±2mm Motorized Varifocal, auto Focus,| Electronic Shutter: 1/7.5~1/13000 with preferred shutter control | Digital Slow Shutter (DSS): 1/7~1/30 (NTSC); 1/7~1/25 (PAL) | White Balance: Auto/Manual | Automatic Gain Control (AGC): Auto | Noise Reduction: 3D | Image Resolution: 2592 x 1944 | Compression: H.265 / H.264 / MJPEG | Frame Rate and Bit Rate: 30 fps with WDR, Controllable bit rate, frame rate and Maximum Bit rate | Video Streams: Triple streaming, individually configurable streams. Two of the streams configurable at H.265, full resolution, full frame rate | Smart Compression: Smart GOP | Rate Control: CBR, VBR, MJPEG | Motion Detection: Yes, built-in with multiple configurable areas in the video stream | Image Enhancement: Built-in WDR, HLC, BLC | Wide Dynamic Range: 120 dB | IR: 40 Meter (Built-in or External) IR | Alarm & Audio Connectors: 1 Input & 1 Output for Alarm & Audio Interface | Analytics: Video Motion Detection, Tampering detection, Object counting, Line crossing, Zone object counting, Zone intrusion, Loitering, wrong way detection, Object Left, Object Remove; Alarms can trigger email or SMS notification; The VA is Edge based | Event Actions: FTP, HTTP, Email notification, Edge Storage, Alarm Output, Text Overlay | Edge Storage: microSDXC up to 256 Gb | Protocols: TCP/IP, IPv4, IPv6, UDP, DHCP, RTP, RTSP, NTP, FTP, UPnP, HTTP, HTTPS, SSL, SMTP, DDNS, 802.1x, Bonjour/Zero Config, ONVIF S, G, T, M | Text Overlay: Date & time, and a customer-specific text, camera name etc. | Security: IP address filtering, HTTPS encrypted data transmission, IEEE 802.1X, Digest Authentication | Firmware Upgrade: The firmware upgrade must be done through web interface; The firmware must be available free of cost | Interface: RJ45, 100 Base TX | Enclosure: IP66/IP67, IK10; The camera and housing must be of same make | Power Requirements: PoE IEEE 802.3af, Class 3, DC12V | Operating Temperature: -20°C (-4°F) to +50°C (122°F) | Operating Humidity: 10% to 90% RH (non-condensing) | Certification: UL, CE, FCC, BIS, NDAA Compliant |Mount: Wall Mount / Pole Mount | Compatibility: ONVIF Profile S, G, T, M |Certification required STQC , BIS, FCC, CE, NDAA, |Make- Hanwah,pelco, axis ,i-Pro,Bosch. 2 5MP AI Bullet CameraImage Sensor: 1/2.8 Sony CMOS progressive sensor | Day/Night Operation: Yes with IR Cut Filter | Minimum Illumination: Color: 0.5 lux; B/W 0 Lux with IR | Lens: 2.7~13.5mm ±2mm Motorized Varifocal, auto Focus,| Electronic Shutter: 1/7.5~1/13000 with preferred shutter control | Digital Slow Shutter (DSS): 1/7~1/30 (NTSC); 1/7~1/25 (PAL) | White Balance: Auto/Manual | Automatic Gain Control (AGC): Auto | Noise Reduction: 3D | Image Resolution: 2592 x 1944 | Compression: H.265 / H.264 / MJPEG | Frame Rate and Bit Rate: 30 fps with WDR, Controllable bit rate, frame rate and Maximum Bit rate | Video Streams: Triple streaming, individually configurable streams. Two of the streams configurable at H.265, full resolution, full frame rate | Smart Compression: Smart GOP | Rate Control: CBR, VBR, MJPEG | Motion Detection: Yes, built-in with multiple configurable areas in the video stream | Image Enhancement: Built-in WDR, HLC, BLC | Wide Dynamic Range: 120 dB | IR: 40 Meter (Built-in or External) IR | Alarm & Audio Connectors: 1 Input & 1 Output for Alarm & Audio Interface | Analytics: Video Motion Detection, Tampering detection, Object counting, Line crossing, Zone object counting, Zone intrusion, Loitering, wrong way detection, Object Left, Object Remove; Alarms can trigger email or SMS notification; The VA is Edge based | Event Actions: FTP, HTTP, Email notification, Edge Storage, Alarm Output, Text Overlay | Edge Storage: microSDXC up to 256 Gb | Protocols: TCP/IP, IPv4, IPv6, UDP, DHCP, RTP, RTSP, NTP, FTP, UPnP, HTTP, HTTPS, SSL, SMTP, DDNS, 802.1x, Bonjour/Zero Config, ONVIF S, G, T, M | Text Overlay: Date & time, and a customer-specific text, camera name etc. | Security: IP address filtering, HTTPS encrypted data transmission, IEEE 802.1X, Digest Authentication | Firmware Upgrade: The firmware upgrade must be done through web interface; The firmware must be available free of cost | Interface: RJ45, 100 Base TX | Enclosure: IP66/IP67, IK10; The camera and housing must be of same make | Power Requirements: PoE IEEE 802.3af, Class 3, DC12V | Operating Temperature: -20°C (-4°F) to +50°C (122°F) | Operating Humidity: 10% to 90% RH (non-condensing) | Certification: UL, CE, FCC, BIS, NDAA Compliant |Mount: Wall Mount / Pole Mount | Compatibility: ONVIF Profile S, G, T, M |Certification required STQC , BIS, FCC, CE, NDAA, |Make- Hanwah,pelco, axis ,i-Pro,Bosch. 3 Supply, Installation, Testing & Commissioning of IP PTZ cameraParameter Specification: Image Sensor – 1/2.8 CMOS; Effective Pixels – 1920(H) x 1080(V), 2 Megapixels Minimum; S/N Ratio – More than 55dB; Minimum Illumination – Colour: 0.05Lux @ F1.6; 0Lux @ F1.6 (IR on); Focal Length – 32x Optical Zoom, 16x Digital Zoom; White Balance – Auto, ATW, Indoor, Outdoor, Manual; Focus Control – Auto / Manual; AGC Control – Auto / Manual; Back Light Compensation – BLC / HLC / WDR (120dB); Pan Travel – 0°360° endless; Pan Speed – 0.1° ~ 300°/sec; Tilt Travel – -15° ~ 90° auto flip 180°; Tilt Speed – 0.1° ~ 200°/sec; Manual Speed – Pan: 0.1° ~ 300°/s; Tilt: 0.1° ~ 200°/s; Presets – 300; Day/Night IR Cut Filter – Auto (ICR) / Color / B/W; Video Compression – H.265 / H.264 / MJPEG; Video Streaming – Main stream: 1080P/720P/1.3M (125/30fps); Sub stream2: 1080P/1.3M/720P/D1/CIF (1~25/30fps); Networking – RJ-45 (10/100Base-T); Protocols – IPv4/IPv6, HTTP, HTTPS, SSL, TCP/IP, UDP, UPnP, ICMP, IGMP, SNMP, RTSP, RTP, SMTP, NTP, DHCP, DNS, PPPOE, DDNS, FTP, IP Filter, QoS, 802.1x, ONVIF, PSIA, CGI; Alarm – 2 In / 1 Out; Operating Temperature – -40ºC ~ 70ºC; Weatherproof Standard – IP66; Power Source – AC 24V / 3A (±10%), PoE+ (802.3at); Power Consumption – 13W (normal), 23W (IR on); Memory – Up to 128GB; Certification – STQC/NDAA/UL/GDPR/NIST/TPM/ISO 27032/Indian Govt; OEM Make – Pelco /Vicon/Hanwha/Axis/Bosch. 4 4K AI Bullet CameraImage Sensor: 1/2” progressive scan RGB CMOS | Day/Night Operation: Yes with IR Cut Filter | Minimum Illumination: Colour: 0.5 lux; B/W: 0 Lux with IR | Lens:7–210 mm (+/-7mm), IR corrected, Megapixel, Motorized Zoom, Auto Focus | Electronic Shutter: 1/7.5 to 1/15000 sec | Image Resolution: 3840x2160 | Compression: H.264, H.265 | Frame Rate & Bit Rate: 30 fps with WDR, controllable bit rate and frame rate | Video Streams: 4 streams, individually configurable, H.265, full resolution and full frame rate | Motion Detection: Built-in with multiple configurable areas | Defog: Built-in | Electronic Image Stabilization: Built-in | Image Enhancement: Built-in WDR, HLC, BLC, Barrel/Lens Distortion | Wide Dynamic Range: Up to 120dB | IR: 70 meters (Built-in or External) | Alarm & Audio Connectors: 1 Input & 1 Output | Analytics: Intrusion, Line Crossing, Unattended Object, Missing Object, Slip & Fall Detection, Vehicle Subtypes (Car, Pickup Truck, Large Truck, Van, Bicycle, Motorcycle, Bus), People, Crowd Size & Growth | Event Actions: FTP, HTTP, Email Notification, PTZ Preset, Edge Storage, Alarm Output, Text Overlay | Edge Storage: 256 GB or Above | Protocols: IPv4, IPv6, TCP/IP, UDP/IP, RTP (UDP/TCP), RTCP, RTSP, NTP, HTTP, HTTPS, SSL/TLS, DHCP, FTP, SMTP, ICMP, IGMP, SNMPv1/v2c/v3 (MIB-2), ARP, DNS, DDNS, QoS, LLDP, CDP, SRTP (TCP/UDP Unicast), MQTT | Text Overlay: Date & Time, Custom Text, Camera Name, Graphic Image | Security: HTTPS (SSL), Digest Login, IP Filtering, User Access Log, 802.1X (EAP-TLS, EAP-LEAP), ETSI EN 303 645, Secure Element (FIPS 140-3 Level 3, CC EAL6+), Secure Boot, Firmware Forgery Verification, Brute-force Prevention | Firmware Upgrade: Web-based, Free of Cost | Interface: RJ-45, 100Base-TX | Memory: 2GB RAM, 512MB Flash | Enclosure: IP66/IP67, IK10, NEMA 4X | Power Requirement: PoE | Operating Temperature: 0°C to 55°C | Operating Humidity: Max 90% RH | Certification: UL, CE, FCC, BIS, ROHS, EMC, NDAA Compliant | Safety: UL 62368-1, CAN/CSA C22.2 NO. 62368-1, IEC/EN 62471 | Environment: IEC/EN 63000, IEC/EN 60529 IP66/IP67, IEC/EN 62262 IK10, NEMA-TS2 (2.2.7.2–8, 2.2.8, 2.2.9), NEMA 250 Type 4X | API: Interface for integration with 3rd party analytics and public domain applications | Mount: Wall Mount / Pole Mount | Compatibility: ONVIF Profile S, G, T, M |Certification required STQC , BIS, FCC, CE, NDAA, |Make- Hanwah,pelco, axis ,i-Pro,Bosch. 5 Supply of ANPR license with Processing Unit with Central Control Software 6 Installation&Commissioning of ANPR licensewithProcessingUnit with Central Control Software 7 Face Recognition System System Type: AI-based Face Recognition system for real-time and recorded video analytics | Applications: Security & surveillance, access control, people management, process automation, and business intelligence | Facial Detection: Detects faces with a minimum of 10 pixels IOD (Interocular Distance) | Facial Recognition: Recognizes faces from 24 pixels IOD (50 pixels recommended) | Recognition Accuracy: ≥ 90% | Identification Speed: ≤ 0.1 seconds within a database of 1 million entries | Processing Capacity: Capable of handling up to 600 fps in 1080p HD video | Demographics Detection: Supports gender and age detection | Custom Lists: Unlimited list creation (e.g., White List, Black List, VIP List) | Real-Time Alerts: Alerts generated based on list match in real-time | Supported Operating Systems: Windows 10 and later; Windows Server 2016 and later | Platform Architecture: 64-bit (x64) | Hardware Acceleration: Intel OpenVINO/ NVIDIA TensorRT supported | Database Support: Compatible with MySQL, PostgreSQL, MS SQL, and Oracle | Input Stream Protocols: RTSP, HTTP, HTTPS, ONVIF | Video File Formats: MKV, MP4, ASF, AVI, MJPEG | Supported Codecs: MPEG-4, MJPEG, H.264, H.265 | Output Formats: JSON, XML, CSV, PDF | User Access Control: Role-based access via Active Directory / LDAP integration | Data Security: Encryption of all communication packages | Centralized Management: Central dashboard for analytics and system control | Business Logic Builder: Enables creation of custom workflows and logic | Notification System: Real-time notification and event triggering based on defined conditions | Event Statistics: Dashboard with hourly, daily, weekly, and monthly analytics | BI Tool Integration: Integration with Microsoft Power BI, Google Data Studio, etc. | Language Support: Multi-language user interface supported 8 Server For Facial RecognitionsystemProcessor (CPU) Intel Xeon Silver/Gold Series, minimum 12 cores, scalable architecture | Memory (RAM) 32 GB DDR5 ECC Registered RAM (RDIMM), expandable up to 128 GB or higher | Primary Storage (SSD) 240 GBSSD, 2.5 or| Operating System Microsoft Windows Server 2019 or newer, 64-bit, OEM Licensed | Graphics Processing Unit (GPU) NVIDIA RTX 4070 or server-grade GPU (e.g., NVIDIA A4000) | Power Supply Unit (PSU) Minimum 750W High-Efficiency Redundant PSU, 80 Plus Gold or Platinum Certified | Chassis / Form Factor Rackmount (2U/4U) or Tower Server Chassis with optimized airflow and expansion | Network Interface Dual/Quad-port Gigabit Ethernet (RJ45)| Cooling System Enterprise-grade cooling with redundant fans or liquid cooling as required | Certifications RoHS, CE, FCC, Microsoft Windows Server Certification, OEM Compliance Certificate |Make / OEM: HP/Dell 9 FIBRE OPTIC CABLE 10 SITC of 8TB Storage (HDD) 11 Supply, Installation, Testing & Commissioning 42 U Rack with Require IPDU and Rack mount KVM Switch with 17 Integrated Display 12 SITC of 9 inch Rack 13 Light Interface Unit (LIU) 14 SC connector per core 15 SITC of Sc-SC Duplex fibre patch cord SM 9/125 - 3mtr 16 Category 6 Shielded Outdoor CableCable Type: Category 6 (Cat 6), Armoured with steel wire or corrugated steel tape, U/UTP, F/UTP, or SF/UTP (as per requirement), Solid Bare Copper (23 AWG) | Conductor and Insulation: Conductor Diameter 0.56 mm to 0.58 mm, 99.99% Pure Bare Copper, Insulation Material: High-Density Polyethylene (HDPE), 4 twisted pairs |Shielding & Armouring: Shielding F/UTP or SF/UTP, Armor: Galvanized Steel Wire or Corrugated Steel Tape, Protection: Anti-rodent and anti-termite, Drain Wire: Tinned copper (in shielded cables) |Outer Sheath: UV-resistant, flame-retardant Polyethylene or LSZH, Colour: Black (standard for outdoor use), Outer Diameter: Approx. 10–12 mm, Marking: Sequential length marking at every 1 meter |Performance Standards: Compliance with ANSI/TIA-568.2-D, ISO/IEC 11801, EN 50173, RoHS, Application: 10/100/1000 Base-T Ethernet, PoE/PoE+, CCTV over IP | Environmental Specifications: Operating Temp: -20°C to +75°C, Storage Temp: -40°C to +75°C, UV Resistance: Yes, Water Resistance: Water-blocking gel or dry tape (optional), Installation: Direct burial, duct, or conduit |Certifications Required: UL / ETL / CE, OEM Test Report, RoHS, Factory Test Certificate |Make / OEM: CommScope / Belden / R&M / AMP / Digisol 17 SITC of 24 Port CAT-6 UTP Jack panel with cable manager 18 3 Feet Patch Chord 19 Supply, Installation, Testing & commissioning of 42inches LED monitor, Full HD Resolution, Backlight LED, Brightness : 400 NITS min., Contrast : 1200 : 1 or better., Power supply : 230 ±10%, 50 Hz. 20 24 Port +4 10G SFP+ Fibre Optic Switch 21 Supply, Installation, Testing & Commissioning of 24 Port 1G switch 22 SITC of Single Mode 1G SFP - 10KM Module with installation 23 Supply, intsallationof Operator terminal Intel Processor basedPCwith i7 processor,1TBHDD,16 GB RAM, 20.5 inch LED Monitor,4GBgraphiccard with NVIDA facility,with the Licencse copy of operating System, Microsoft office. With 256 GB SSD. 24 Recording Server for VMS Software support up to 70 CCTV Camera (5MP)Form Factor 2U Rack Server | Processor Intel Xeon Silver 4310, 2.1GHz, 12C/24T, 10.4GT/s, 18MB Cache, Turbo, Hyper-Threading, 120W, DDR4-2666 | Memory 32GB RDIMM DDR4, 2666 MT/s, ECC, up to 16 DIMM slots | Storage Chassis 3.5 with up to 8 Hot-Swap Hard Drives | RAID Controller PERC H755 RAID Controller | Power Supply Dual Hot-Plug Redundant PSU (1+1), 800W, Mixed Mode | Additional Features Redundant power, high availability design, scalable memory and storage capacity| Operating System Microsoft Windows Server 2019 or newer, 64-bit, OEM Licensed|Make / OEM: HP/Dell 25 Supply of VMS software camera License for ENTERPRISE Master server system: Make. Hanwah,pelco, axis ,i-Pro,Bosch and Network Optix. 26 VMS Maintenance and support services per year 27 Splicing of OFC Cable (Per pair) 28 Supply, Installation, testing, commissioning, performance demonstration of 2 KVA UPS true online with 1 phase input, 1 phase output with back up batteries for 2 Hours backup along with rack & connectors. 29 1st category Cu armoured cables FRLS outer sheathed- 4C x 2.5 Sq.mm 30 IP 42 Wall/column Mounted distribution board with one Nos of DP 16/32A MCB as incomer and 2 Noss 6A/10A SP MCB as outgoing (8 way SPN DB) 31 Clean Agent Fire Extinguisher 32 Rebate of old Cameras / DVRs along with cables and accessories. 33 CSMC 5% for 2nd year after completing 1 year DLP 34 CSMC 5% for 3rdyear 35 CSMC 5% for 4thyear 36 CSMC 5% for 5thyear
Contract Date: Dec 24, 2025 Contract Value : 4.27 Crore
Local Bodies No of Bidders 3
Maharashtra View Result →
23.
Civil Aviation #8476555 AOC
Tender For Supply, Installation, Testing And Commissioning Of Turn Pad Lights And Guard Lights At Lilabari Airport; 1 Supply of FAA Certified Inset type LED Uni Directional Runway TurnPad medium intensity light fitting (Green) for aviation visual aids requirements complete with shallow base and matching body of the fitting, inner body of the fitting, inner body and outer cover made of die cast aluminium complete with LED lamp with integral driver and electronics suitable for 6.6 Amps current with connected heat resistant accessories, prism assembly, optical assembly, O ring seal, pressure relief test plug, hardware, lenses and all standard accessories and ready for site installation as per sepcifications complete as required. 2 Supply of high intensity Elevated Runway guard light with two flashing light fixtures with black independent visors, 6.6A Current driven input power supply, LED lamps/module , flashing rates 45-50 Per Minute, frangible support, high strength base plate for runway guard light to resist wind speed (300 mph) gaskets, SS hardware etc conforming to latest ICAO / CAR requirement as per specifications complete as required. 3 Supply of1 x 16 Sq.mm size5 KV grade Airfield Lighting Cable copper conductor XLPE insulated, PVC sheathed, unshielded, anti-termite and rodent treated, UGairfield lighting cable generally confirming to IS:7098 (Part-II) with up to date amendments and particular specifications of the following sizes as required: 4 Supply of following sizes 5 KV grade dry type plug and receptacleprimary connector kit with field attachment and suitable for 5 KV grade single core copper conductor,XLPE insulated PE outer sheathed unshielded cable,. complete as required and confirming to the technical specification. (a) 16 sq mm 5 Supply of 1.1 KV grade EPR insulated PCP/TPE sheathed secondary lead airfield lighting cable of size 2 x 2.5 Sq.mm having multistranded tinned copper conductor and colour coded core for connecting between isolation transformer and Inset light fitting complete as required. 6 Supplyoffollowing size Anti Rodent Fire Retardant Permanently lubricated HDPE (High density polyethylene) pipe along with necessaryaccessories complete as required and as per the technical specificationsetc. complete as required.OD 63 mm 7 Supply of following rating 5000V, 50 Hz series Isolating Transformers encapsulated in polyester resin, finally moulded in neoprene type rubber and with primary and secondary connections conforming to specification as required.15 Watts 20/6.6 Amps 8 Supply of following rating 5000V, 50 Hz series Isolating Transformers encapsulated in polyester resin, finally moulded in neoprene type rubber and with primary and secondary connections conforming to specification as required.65 Watts 6.6/6.6 Amps 9 Supply of CI isolating transformer housing box, water tight round type, metal container of outside size 330mm, height 450mm made of 10 mm thick cast iron moulding all round, except the top surface, which is 15 mm thick, cast iron moulding suitable to receive a light fitting base plate on the top and underground housing associated with transformerpower cable and having a clear hole centre at one side surface centre 75mm above bottom surface suitable to receive two no. of 63 mm dia B class GI pipe / HDPEand one no of 15 mm dia B class GI pipe with check nuts as required .The box should have two SS earth bolts of M10 x 30mm tapped inside near the hole (4 away from the hole centre) and having a drain hole at the bottom suitably tapped to receive 15mm dia B class GI pipe and having clear opening of 220mm at thetop surface and 6 nos M10 tapped hole at the hole centre 260mm to receive fitting base plate and bolts, check nuts etc. as required as per the drawings.TRIPLE HOLE (02 nos 63 mm dia & 01 no 15 mm dia) 10 Installation, Testing and Commissioning of inset type turn pad centre line light fitting in the runway with core cutting,setting i/c providing sealing material and other accessoriesinter connections etc., as required for commissioning. 11 Installation, testing and commissioning of Elevated type Runway guard lights by providing suitable cement concrete foundation as per manufacturer recommendation/as per direction of E-I-C, installing transformer, lens, lamps gasket,nut bolts, lens holding clamp and other accessories i/c alignment, connection, earth connection etc. as complete as required. 12 Layingoffollowing dia high density polyethylene (HDPE ) pipe, complete with accessories. in the soil for GLF work up to 750 mm deep connecting both/one end to existing chamber/CC collar, including excavation and back filling & making good the same as per site requirement .OD 63 mm 13 Laying ofhigh density polyethylene HDPE pipe of OD 63 mmcomplete with accessories. in the shoulder/runway/taxiway of Concrete/bitumen surfacei/c machine cutting of runway/taxiway/shoulder surface ofwidth up to110 mm and up to 200 mm deep, and taking the excavated material out of the area within a lead up to2 kms and refilling & making good the same by Cement Concrete ( 1:2:4 ) as per the site requirement. 14 Laying of one numberPVC insulated and PVC sheathed/ XLPE power cable of 5 KV/1.1KVgrade of up to 35 sq.mm in the existing RCC/HUME/STONE WARE/METAL/DWC/HDPE pipe as required. 15 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV/5 KVgrade of up to 35 sqmm size in the existing masonry open duct as required 16 Laying and fixing of one number PVC insulated and PVCsheathed / XLPE power cable of 1.1 KV/5kV grade of size up to 35 sqmm (clamped with 1mm thick saddle)on cable tray/surface as required 17 Excavation of the cable trenches in hard rock not exceeding 1.5 meter in width, and lift up to 1.5 meter, including getting out the excavated soil and disposal of excavated soil as directed within a lead of 50 meter. 18 Providing and laying in position cement concrete 1:2:4 (1cement : 2 coarse sand : 4 graded stone aggregate 20 mmnominal size) as per direction of E-I-C. 19 Making field connection of 5 KV grade 6/16 sq.mm single core copper conductor,XLPE insulated PE outer sheathed unshielded cable with dry type plug & receptacle of i/c crimping & fixing, applying HT tape , etc as well as checking continuity with the existing ckts etc. complete as required as per EIC 20 Installation of round type transformer housing box with base concrete of 1:3:6 of size 630 x 630 x 100 mm thick all around concrete of 1:2:4, 150mm thick top slopped with 1:2:4 cement concrete including providing and fixing 10 long 1/2 dia B class GI pipe with check nuts for drainage of water including excavation and refilling, aligning the boxes in straight line etc complete as required. 21 Modification of Existing ALCMS System including Integration of new CCRS/GLF facilities with existing ALCMS installed at ATC tower, CCR hall including modification of mimic diagram complete as per directions of engineer-In-Charge. 22 Providing and laying of 15 mm dia B class GI pipeincluding groove cutting, threading and alignment of pipe with transformer housing box, inset fittings, providing check nuts and couplings etc as required on the runway and disposal of excavated materials within a lead of 50 meter. 23 Provision of Micro concrete plaster on existing groove cut portion above the GI pipe/damaged portion in the tarmac runway and finishing as per directions of E-I-C. 24 Making field connections by crimping 2 X 2.5 sq.mm. (two pin) plug and receptacle assembly with the existing 2X2.5 sqmm secondary lead cable including filling with gap with water sealant material applying water proof tape, over which PVC tape etc., one side of the secondary lead for connecting to isolation transformer and receptacle assembly on other side for connecting to light fitting as required. 25 Supply and fixing of 10mm thick MS dummy plate of 330 mm dia having 6No X M-10 holes along the circumferential of 260mm dia suitable to install on existing transformer housing box including providing and fixing of rubber gasket and SS bolts, nuts, washers etc., as required. 26 Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. 27 Providing and fixing 6 SWG dia G.l. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ sub main wiring/ cable as required.
Contract Date: Oct 07, 2025 Contract Value : 1.79 Crore
Boards / Undertakings / PSU No of Bidders 3
24.
Petroleum and Natural Gas #8436902 AOC
Annual Rate Contract For Civil And Other Miscellaneous Maintenance Works At Wrpl Beawar And Sendra Station=10 NRECIV0001: Cleaning mosaic floor with Carborundum block stone, oxalic acid and caustic soda for all heights of all patches, spots a nd polishing with Mansion polish with all tools, tackles, consumables, materials & labour all complete. 20 NRECIV0002: Through cleaning of paved and unpaved areas, roads, road side berms, broming removal of scraps and other unwanted left o ver materials including removal of chockage in the drains, removal of chockage from the road side / pave or unpaved area side drains and disposal of the rubbish etc. to the nearest garbage bin or as directly by Engineer-in-charge including laboures, broom, trolley and other consumables etc.complete. 30 NRECIV0003: Cleaning the tiles, lavatory, flooring, urinals etc. by removing stains etc. by using Vim powder / cleaning powder / ISI grade black phenyle / while phenyle / Acid /Naptha balls / Coir brushes / wire brushes / Finit in required proportion to make the a rea clean and free from all dust, dirt and stains etc. including cost of all labour and materials complete. (Only floor area shall b e measured). 40 NRECIV0004: Mopping of floors of offices, toilets, control rooms, electrical sub station etc. with soap solution or phenyle water wi th wet cloth after sweeping the floor with phooll broom, removing cob-webs with all tools, tackles, labour & materials etc. complete as per directions of Engineer -in-charge including cleaning of ventilator glass panes from both the sides upto any height with clea ning powder,paint remover as per requirement all labour, material etc.complete. 50 NRECIV0005: Carrying out miscellaneous activities related to general maintenance like daily dusting the furnitures, walls shelves, c leaning the carpets, sofas, Cleaning and sweeping the stair case, passages, backyard, verandah, garrages, removal of cow webs, with all labours, tools & tackles complete including supervising charges. (Unit EA shall mean carrying out above activities for 8 hrs. a day). 60 NRECIV0006: Removing stains, paints, washing & cleaning the window & ventilator glass panes from both the sides upto any height with cleaning powder, paint remover as per requirement all labour, materials etc. complete.: Glass pane not exceeding 1.00 sq.m in area 70 NRECIV0007: Removing stains, paints, washing & cleaning the window & ventilator glass panes from both the sides upto any height with cleaning powder, paint remover as per requirement all labour, materials etc. complete.: Glass pane exceeding 1.00 sq.m in area 80 NRECIV0008: Collection of Kitchen waste, dry waste & toxic waste in offices and colony from all Residential & Public Buildings, Exec utive Hostel, Staff Hostel, Canteen, Guest House, Club etc. The workmen shall collect the waste from each house & Public Buildings, segregate the waste into biodegradable & non bio-degradeable waste and finally dispose themseparately at designated place (Dumping Yard/ Pit) on daily basis as per requirement, with trained workmen, with all labour, tools, tackles, safety & protective clothes etc . complete as per direction of Engineer-in-charge. All consumables required including manpower, tools & tackles, PPEs, uniform to wo rkmen, etc. are to be supplied by Contractor without any extra cost and performing work as per item decription and direction of Engi neer-in-Charge as well as instructions in Special Condition of Contract if any. Payment of Paddle Rickshaw (thela) will be made sepe rately. The unit MONTH (MON) shall mean per house/building per month 90 NRECIV0009: Cleaning and desilting of drains, side slopes in or under water or above water level and along drain both sides upto 1.0 metre width including removal of grass, bushes, vegetation, debris, sludge and any other unwanted material and disposal of the same at places as directed by Engineer-in-Charge within owners premises including all labour, materials, tools, tackles, transportation for all lead and lifts as directed.: Cross section of drain upto 2.0 sqm. 100 NRECIV0010: Cleaning and desilting of drains, side slopes in or under water or above water level and along drain both sides upto 1.0 metre width including removal of grass, bushes, vegetation, debris, sludge and any other unwanted material and disposal of the same at places as directed by Engineer-in-Charge within owners premises including all labour, materials, tools, tackles, transportation for all lead and lifts as directed.: Cross section of drain above 2.0 sqm. and upto 4.0 sqm. 110 NRECIV0011: Cleaning and desilting of drains, side slopes in or under water or above water level and along drain both sides upto 1.0 metre width including removal of grass, bushes, vegetation, debris, sludge and any other unwanted material and disposal of the same at places as directed by Engineer-in-Charge within owners premises including all labour, materials, tools, tackles, transportation for all lead and lifts as directed.: Cross section of drain above 4.0 sqm. and upto 10.0 sqm. 120 NRECIV0012: Cleaning and desilting of drains, side slopes in or under water or above water level and along drain both sides upto 1.0 metre width including removal of grass, bushes, vegetation, debris, sludge and any other unwanted material and disposal of the same at places as directed by Engineer-in-Charge within owners premises including all labour, materials, tools, tackles, transportation for all lead and lifts as directed.: Cross section of drain above 10.0 sqm and upto 15.0 sqm. 130 NRECIV0013: Labour charges for cleaning and dechoking of the nahani trap, gully trap and inspection chambers alongwith the CI and S W pipe connection of house drainage including flushing, removal of sludge muck outside all labour, tools etc. complete. The contract or has to clean the line from Nahani trap upto inspection chamber or vice-versa complete. 140 NRECIV0014: Cleaning and removing choking from existing rain water pipe including removing the shoe or grating if necessary & fixin g the same without damaging & fitting of specials all labour etc.complete. Up to 5 mtr. Height 150 NRECIV0015: Cleaning of manholes and removal of chokage in sanitary sewer or CRWS manholes and its allied connection by rodding, st eaming, watering manually or by any applied means, making necessary connection of hoses etc. all as per direction of Engineer-in-Cha rge including plugging and dewatering of manholes removal of muck, sludge, floating materials etc. and disposing, the same to dumping pi t within owners premises as directed with all buckets, ropes, wooden plugs, tools, tackles, consumables, safety equipment pumps, ho ses, operative labour etc. complete.: Manholes of depth upto 2.0 M 160 NRECIV0016: Cleaning of manholes and removal of chokage in sanitary sewer or CRWS manholes and its allied connection by rodding, st eaming, watering manually or by any applied means, making necessary connection of hoses etc. all as per direction of Engineer-in-Cha rge including plugging and dewatering of manholes removal of muck, sludge, floating materials etc. and disposing, the same to dumping pi t within owners premises as directed with all buckets, ropes, wooden plugs, tools, tackles, consumables, safety equipment pumps, ho ses, operative labour etc. complete.: Manholes of depth beyond 2.0 M but upto 3.0M 170 NRECIV0017: Cleaning of manholes and removal of chokage in sanitary sewer or CRWS manholes and its allied connection by rodding, st eaming, watering manually or by any applied means, making necessary connection of hoses etc. all as per direction of Engineer-in-Cha rge including plugging and dewatering of manholes removal of muck, sludge, floating materials etc. and disposing, the same to dumping pi t within owners premises as directed with all buckets, ropes, wooden plugs, tools, tackles, consumables, safety equipment pumps, ho ses, operative labour etc. complete.: Manholes of depth beyond 3.0M 180 NRECIV0018: Cleaning of manholes and removal of chokage in OWS manholes and its allied connection by rodding, steaming, watering man ually or by any applied means, making necessary connection of hoses etc. all as per direction of Engineer-in-Charge including pluggi ng and dewatering of manholes, removal of muck, sludge, floating materials etc. and disposing, the same to dumping pit within owner s premises as directed with all buckets, ropes, wooden plugs, tools, tackles, consumables, safety equipment pumps, hoses, operative labour etc. complete.: Manholes of depth upto 2.0 M 190 NRECIV0019: Cleaning of manholes and removal of chokage in OWS manholes and its allied connection by rodding, steaming, watering man ually or by any applied means, making necessary connection of hoses etc. all as per direction of Engineer-in-Charge including pluggi ng and dewatering of manholes, removal of muck, sludge, floating materials etc. and disposing, the same to dumping pit within owner s premises as directed with all buckets, ropes, wooden plugs, tools, tackles, consumables, safety equipment pumps, hoses, operative labour etc. complete.: Manholes of depth beyond 2.0 M but upto 3.0M 200 NRECIV0020: Cleaning of manholes and removal of chokage in OWS manholes and its allied connection by rodding, steaming, watering man ually or by any applied means, making necessary connection of hoses etc. all as per direction of Engineer-in-Charge including pluggi ng and dewatering of manholes, removal of muck, sludge, floating materials etc. and disposing, the same to dumping pit within owner s premises as directed with all buckets, ropes, wooden plugs, tools, tackles, consumables, safety equipment pumps, hoses, operative labour etc. complete.: Manholes of depth beyond 3.0M 210 NRECIV0021: Cleaning dechoking and flushing inspection chambers and connected drain lines with drain cleaning rods, bamboos, compres sed air, steaming etc. removal of oily muck outside the chamber completed upto 100M lead. The item includes transportation of all ma chinery and plants, all labour, tools etc. complete, taking all necessary safety precautions as specified. Water at one point shall be supplied free of cost, hire charges for compressed air shall be paid separately if required. 220 NRECIV0022: Cleaning, dechoking and flushing 100mm/ 50mm SW and sewer line by removing muck, cleaning etc. with bamboo strips or sew er cleaning rods etc. as directed (section between two chambers) all complete including cleaning of two manholes as per direction of the Engineer-in-Charge. 230 NRECIV0025: Material handling and carriage of any material including (but not limited to) rubbish, debris, earth, sludge, manure, ce ment, sand, furniture, plants, etc. by mechanically driven transport for following leads or part thereof including loading, unloadin g and stacking all complete as per the direction of Engineer-in-Charge (Rates will be applicable to net quantities after deduction o f 20 percent for voids): Upto a lead of 1 km 240 NRECIV0026: Material handling and carriage of any material including (but not limited to) rubbish, debris, earth, sludge, manure, ce ment, sand, furniture, plants, etc. by mechanically driven transport for following leads or part thereof including loading, unloadin g and stacking all complete as per the direction of Engineer-in-Charge (Rates will be applicable to net quantities after deduction o f 20 percent for voids): Lead beyond 1 km but upto 2 km 250 NRECIV0027: Material handling and carriage of any material including (but not limited to) rubbish, debris, earth, sludge, manure, ce ment, sand, furniture, plants, etc. by mechanically driven transport for following leads or part thereof including loading, unloadin g and stacking all complete as per the direction of Engineer-in-Charge (Rates will be applicable to net quantities after deduction o f 20 percent for voids): Lead beyond 2 km but upto 3 km 260 NRECIV0028: Material handling and carriage of any material including (but not limited to) rubbish, debris, earth, sludge, manure, ce ment, sand, furniture, plants, etc. by manual labor / manually driven transport for following leads or part thereof including loadin g, unloading and stacking all complete as per the direction of Engineer-in-Charge (Rates will be applicable to net quantities after deduction of 20 percent for voids): Upto a lead of 50 m. 270 NRECIV0029: Material handling and carriage of any material including (but not limited to) rubbish, debris, earth, sludge, manure, ce ment, sand, furniture, plants, etc. by manual labor / manually driven transport for following leads or part thereof including loadin g, unloading and stacking all complete as per the direction of Engineer-in-Charge (Rates will be applicable to net quantities after deduction of 20 percent for voids): Every additional leads of 50 m or part thereof beyond 1st 50 m upto 9 such additional leads. 280 NRECIV0030: Supply of tractor with trailer on hire charges for 08 hours per day including rendering the services of 4 labourers driv er, fuel and other consumables, tools, tackles etc. for transportation of rubbish/ waste materials complete as per directions of Eng ineer-in-Charge.(8 hours working period of one tractor is considered as one tractor day). Unit EACH (EA) stands for tractor days. 290 NRECIV0031: Edging with common burnt clay F.P.S. (non modular) bricks of class designation 7.5, laid dry length wise, including requ ired excavation, refilling, consolidating with hand packing and spreading surplus earth neatly within a lead of 50m. 300 NRECIV0038: Providing comprehensive pest control services to the building, sheds, cable trenches, drains and other facilities of th e establishment, to control the nuisance of various pests including (but not limited to) rodents, snakes, lizards, beehives, cockroa ches, mosquitoes, Red and Black ants, crawling pests, house flies, fruit flies, etc. Job includes placing / injecting rodenticide ba its, glue trays, snake repellent and other chemicals, insecticides, Fogging/fumigation, Removal of bee hives below ground (in trench es upto depth of 1m) and above ground (up to height of 15m), complete with all labours, materials, tools, and tackles, equipments, c onsumables etc complete. Periodicity of scheduled pest control activities shall be monthly, while ad hoc requirement shall be as and when required as directed by EIC whose decision shall be final. Area of measurement for pest control application shall be designate d by EIC. Rate is For (PER SQM PER MONTH) 310 NRECIV0039: Lifting, shifting, loading, unloading on of heavy equipment / material etc etc with the help of hydra/crane etc (Min 12T ) including all accessories like belt, sling etc as per directions of EIC/ Site- Engineer. (Unit EA shall mean carrying out abov e activities for 8 hrs. a day). 320 NRECIV0040: Hire and running charges of loader. (Unit EA shall mean carrying out above activities for 8 hrs. a day). 330 PJEALU2634: Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubul ar sections/ appropriate Z sections and other sections of approved make conforming to IS:733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM ru bber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever require d including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per arc hitectural drawings and the directions of the Engineer-in-Charge. [Note: Glazing, paneling and dash fasteners to be paid for separat ely] : 340 PJEALU2636: Anodised Aluminium (Anodised transparent or dyed to required shade according to IS:1868, Minimum anodic coating of Grade AC-15) 350 PJEALU2637: Powder coated aluminium (Minimum thickness of powder coating 50 micron) 360 PJEALU2638: Polyester powder coated aluminium (Minimum thickness of polyester powder coating 50 micron) 370 PJEALU2639: For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixi ng of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required. [Note: Fittings shall be paid for sepa rately] : 380 PJEALU2640: Anodised Aluminium (Anodised transparent or dyed to required shade according to IS:1868, Minimum anodic coating of Grade AC-15) 390 PJEALU2641: Powder coated aluminium (Minimum thickness of powder coating 50 micron) 400 PJEALU2642: Polyester powder coated aluminium (Minimum thickness of polyester powder coating 50 micron) 410 PJEALU2650: Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS:6315, havin g brand logo embossed on the body/ plate with double spring mechanism and door weight up to 125 Kg, for doors, including cost of cut ting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per directions of the Engineer-in-Charge. : 420 PJEALU2651: With stainless steel cover plate minimum 1.25 mm thickness 430 PJEALU2652: With brass cover plate minimum 1.25 mm thickness 440 PJEALU2685: Filling the gap in between Aluminium/ Stone/ Wood frame and adjacent RCC/ Brick/ Stone/ Wood/ Ceramic/ Gypsum work by pr oviding weather/ structural non-sag elastomeric PU sealant over backer rod of approved quality as per architectural drawings and dir ections of the Engineer-in-Charge complete, complying to ASTM C920, DIN 18540-F & ISO 11600 : 450 PJEALU2686: Up to 5 mm depth and 5 mm width 460 PJEALU2687: Up to 10 mm depth and 10 mm width 470 PJEALU2688: Up to 20 mm depth and 20 mm width 480 PJEALU2689: Providing and fixing, on fixed glazing/ doors/ window panes, sun control film HP NATURAL 35 SAFETY COMBINATION FILM-4Mi l of M/s. GARWARE or approved equivalent make and shade, all complete as per manufacturers specification and as per directions of the Engineer-in-Charge. 490 PJECLA0192: Marble work gang saw cut (polished and machine cut) Raj Nagar Plain white marble/ Udaipur green marble/ Zebra black marb le of thickness 18 mm for wall lining (veneer work), backing filled with a grout of average 12 mm thick in cement mortar 1:3 (1 ceme nt : 3 coarse sand), including pointing with white cement mortar 1:2 (1 white cement : 2 marble dust) with an admixture of pigment t o match the marble shade [Note: To be secured to the backing by means of cramps, which shall be paid for separately] : 500 PJECLA0193: Area of slab up to 0.50 sqm 510 PJECLA0194: Area of slab over 0.50 sqm 520 PJECLA0195: Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut Raj Nagar Plain white marble/ Udaipur green marble/ Zebra black marble for kitchen platforms, vanity counters, window sills, facias and similar loca tions of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels : 530 PJECLA0196: Area of slab up to 0.50 sqm 540 PJECLA0197: Area of slab over 0.50 sqm 550 PJECLA0198: Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut Granite stone sl ab of colour black, Cherry/Ruby red for kitchen platforms, vanity counters, window sills, facias and similar locations of required s ize, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with जोधर्पुर matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels : 560 PJECLA0199: Area of slab up to 0.50 sqm 570 PJECLA0200: Area of slab over 0.50 sqm 580 PJECLA0201: Providing edge moulding to 18 mm thick Marble/ Granite stone counters, Vanities etc., including machine polishing to edg e to give high gloss finish etc. complete as per design approved by the Engineer-in-Charge : 590 PJECLA0202: Marble work 600 PJECLA0203: Granite work 610 PJECLA0206: Mirror polishing on Marble work/ Granite work/ Stone work wherever required to give high gloss finish complete. 620 PJECLA0220: Providing and fixing machine cut, mirror/ eggshell polished Italian Marble stone slab (Perlato, Rosso verona, Fire Red o r Dark Emperadore etc.) of 18 mm thickness for wall lining (veneer work) including dado, skirting, risers of steps etc., in required design and pattern wherever required, stones of different finished surface texture, on 12 mm (average) thick cement mortar 1:3 (1 c ement : 3 coarse sand) laid and jointed with white cement slurry @ 3.3 Kg/sq.m. including pointing with white cement slurry admixed with pigment of matching shade, including rubbing, curing, polishing etc. all complete as per Architectural drawings, and as directe d by the Engineer-in-Charge : 630 PJECLA0221: Extra for stone work for wall lining on exterior walls of height more than 10 m from ground level for every additional h eight of 3 m or part thereof. 640 PJECLA0222: TILE WORK IN CLADDING : 650 PJECLA0223: Providing and fixing first quality ceramic glazed wall tiles conforming to IS:15622 (thickness to be specified by the ma nufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by the Engineer-i n-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 Kg/sq.m., including pointing in white cement mixed with pigment of matching shade complete. 660 PJECON0069: CEMENT CONCRETE (CAST IN-SITU) : 670 PJECON0070: Providing and laying in position cement concrete of specified grade at all depths including ramming & shuttering etc. c omplete in all respects inclusive of cost of all labour, materials, tools, tackles etc. as per drawings, specifications and directio n of Site Engineer: 680 PJECON0071: 1:1.5:3 [1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal siz e derived from natural sources] 690 PJECON0072: 1:2:4 [1 cement : 2 coarse sand (Zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size de rived from natural sources] 700 PJECON0074: 1:3:6 [1 cement : 3 coarse sand (Zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size de rived from natural sources] 710 PJECON0078: Providing and laying damp-proof course 50 mm thick with cement concrete 1:2:4 [1 cement : 2 coarse sand (Zone-III) deriv ed from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources] laid to proper level & line incl uding providing shuttering & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7 Kg per sq uare metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil etc. complete in all respects inclusive of cost of all labour, materials, tools, tackles etc. as per drawings, specifications a nd direction of Site Engineer. 720 PJECON0080: Making plinth protection 50 mm thick of cement concrete 1:3:6 [1 cement : 3 coarse sand derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources] over 75 mm thick bed of dry brick ballast 40 mm nominal siz e, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth, etc. complete in all respects inclusive of cost of all labour, materials, tools, tackles etc. as per drawings, specificatio ns and directions of the Engineer-in-Charge. 730 PJECON0082: Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manuf acturers specification. [Note: Unit KG shall mean PER BAG OF 50 KG OF CEMENT]. 740 PJECON0085: Providing and laying cement concrete in kerbs, steps and the like at or near ground level excluding the cost of centerin g, shuttering and finishing: 1:1.5:3 [1 cement: 1.5 coarse sand (Zone-III) derived from natural sources : 3 graded stone aggregate 2 0 mm nominal size derived from natural sources] 750 PJECON0087: Providing and fixing up to floor five level precast cement concrete string or lacing courses, copings, bed plates, ancho r blocks, plain window sills, shelves, louvers, steps, stair cases, etc. including hoisting and setting in position with cement mort ar 1:3 (1 cement : 3 coarse sand), cost of required centering complete: 1:1.5:3 [1 cement : 1.5 coarse sand (Zone-III) derived from natural sources : 3 graded stone aggregate 20mm nominal size derived from natural sources] 760 PJECON0088: Providing and fixing at or near ground level precast cement concrete in kerbs, edgings etc. as per approved pattern and setting in position with cement mortar 1:3 (1 Cement : 3 coarse sand), including the cost of required centering, shuttering complete : 1:1.5:3 [1 cement: 1.5 coarse sand (Zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources] 770 PJEDIS1159: Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per th e directions of Engineer-in-Charge. [Notes: (1) Dismantling shall be allowed during day shift only & prior permission for the same s hall be obtained. (2) Providing of necessary covers/ barricades around the work area shall be done prior to dismantling operations] : 780 PJEDIS1160: Nominal concrete 1:3:6 or richer mix (including equivalent design mix) 790 PJEDIS1161: Nominal concrete 1:4:8 or leaner mix (including equivalent design mix) 800 PJEDIS1162: Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable mat erial within 50 metres lead as per the directions of Engineer-in-Charge. [Notes: (1) Dismantling shall be allowed during day shift o nly & prior permission for the same shall be obtained. (2) Providing of necessary covers/ barricades around the work area shall be d one prior to dismantling operations. (3) Cutting of all reinforcement shall be done using hack saw or chiesel or any other method as approved by the Engineer-in-Charge] 810 PJEDIS1163: Demolishing R.B. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable mate rial within 50 metres lead as per the directions of Engineer-in-Charge. [Notes: (1) Dismantling shall be allowed during day shift only & prior permission for the same shall be obtained. (2) Providing of n ecessary covers/ barricades around the work area shall be done prior to dismantling operations] 820 PJEDIS1164: Extra for cutting reinforcement bars manually/ by mechanical means in R.C.C. or R.B. work as per direction of the Engine er-in-Charge. [Notes: (1) Cutting of all reinforcement shall be done using hack saw or chiesel or any other method as approved by th e Engineer-in-Charge. (2) Payment shall be made on the cross sectional area of R.C.C. or R.B. work] 830 PJEDIS1165: Extra for scrapping, cleaning and straightening reinforcement from R.C.C. or R.B. work. 840 PJEDIS1166: Demolishing brick work in cement mortar manually or by mechanical means including stacking of serviceable material and d isposal of unserviceable material within 50 metres lead as per the directions of Engineer-in-Charge. [Notes: (1) Dismantling shall b e allowed during day shift only & prior permission for the same shall be obtained. (2) Providing of necessary covers/ barricades aro und the work area shall be done prior to dismantling operations] 850 PJEDIS1168: Demolishing stone rubble masonry in cement mortar manually/ by mechanical means including stacking of serviceable materi al and disposal of unserviceable material within 50 metres lead as per the directions of Engineer-in-Charge. 860 PJEDIS1171: Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc . complete and stacking within 50 metres lead : 870 PJEDIS1172: Of area 3.0 sq. metres and below 880 PJEDIS1173: Of area beyond 3.0 sq. metres 890 PJEDIS1177: Dismantling steel work in single sections including dismembering and stacking within 50 metres lead in : 900 PJEDIS1178: Rolled Steel Joists 910 PJEDIS1179: Channels, angles, tees and flats 920 PJEDIS1181: Dismantling steel work manually/ by mechanical means in built up sections without dismembering and stacking within 50 me tres lead as per direction of Engineer-in-charge. [Notes: (1) Dismantling shall be allowed during day shift only & prior permission for the same shall be obtained. (2) Providing of necessary covers/ barricades around the work area shall be done prior to dismantlin g operations. (3) Cutting of steel shall be done using hack saw or chiesel or any other method as approved by the Engineer-in-Charge .] 930 PJEDIS1185: Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead : 940 PJEDIS1186: For thickness of tiles 10 mm to 25 mm 950 PJEDIS1187: For thickness of tiles above 25 mm and up to 40 mm 960 PJEDIS1188: Demolishing dry brick pitching in floors, drains etc. including stacking serviceable material and disposal of unservicea ble material within 50 metres lead. 970 PJEDIS1190: Demolishing brick tile covering in terracing including stacking of serviceable material and disposal of unserviceable ma terial within 50 metres lead. 980 PJEDIS1191: Demolishing mud phaska in terracing and disposal of material within 50 metres lead. 990 PJEDIS1192: Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead of : 1000 PJEDIS1193: G.S. Sheet 1010 PJEDIS1194: Asbestos Sheet 1020 PJEDIS1198: Dismantling barbed wire or flexible wire rope in fencing including making rolls and stacking within 50 metres lead. 1030 PJEDIS1200: Dismantling precast concrete or stone slabs in walls, partition walls etc. including stacking within 50 metres lead : 1040 PJEDIS1201: Thickness up to 40 mm 1050 PJEDIS1202: Thickness above 40 mm up to 75 mm 1060 PJEDIS1204: Dismantling C.I. or asbestos rain water pipe with fittings and clamps including stacking the material within 50 metres l ead : 1070 PJEDIS1205: 75 to 80 mm dia pipe 1080 PJEDIS1206: 100 mm dia pipe 1090 PJEDIS1207: 150 mm dia pipe 1100 PJEDIS1208: Dismantling manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable mater ial within 50 metres lead as per the directions of Engineer-in-Charge. [Notes: (1) Dismantling shall be allowed during day shift onl y & prior permission for the same shall be obtained. (2) Providing of necessary covers/ barricades around the work area shall be don e prior to dismantling operations.(3) Adequate safety precautions shall also be taken care before commencement of any activity] : 1110 PJEDIS1209: Water Bound Macadam Road 1120 PJEDIS1210: Bituminous Road 1130 PJEDIS1211: Dismantling G.I. pipes (external work) including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means including stacking of pipes within 50 metres lead as per the directions of Engineer-in-Charge : 1140 PJEDIS1212: 15 mm to 40 mm nominal bore 1150 PJEDIS1213: Above 40 mm nominal bore 1160 PJEDIS1214: Dismantling C.I. pipes including excavation and refilling trenches after taking out the pipes, manually/ by mechanical m eans breaking lead caulked joints, melting of lead and making into blocks including stacking of pipes & lead at site within 50 metre lead as per the directions of Engineer-in-Charge : 1170 PJEDIS1215: Up to 150 mm diameter 1180 PJEDIS1216: Above 150 mm dia up to 300 mm dia 1190 PJEDIS1217: Above 300 mm diameter 1200 PJEDIS1221: Dismantling asbestos cement pressure pipes including excavation and refilling trenches after taking out the pipes manual ly/ by mechanical means and stacking the pipes within 50 metres lead as per the directions of Engineer-in-Charge : 1210 PJEDIS1222: Up to 150 mm diameter 1220 PJEDIS1223: Above 150 mm diameter 1230 PJEDIS1224: Taking out C.I. cover with frame from R.C.C. top slab of manholes of various sizes including demolishing of R.C.C. work manually/ by mechanical means and stacking of useful materials near the site and disposal of unserviceable materials within 50 metre s lead as per the directions of Engineer-in-Charge. 1240 PJEDIS1228: Dismantling of flushing cistern of all types (C.I./ PVC/ Vitrious China) including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead. 1250 PJEDIS1232: Dismantling of spindle fire hydrant including stacking of useful materials within 50 metres lead. 1260 PJEDIS1233: Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. 1270 PJEDIS1234: Dismantling aluminium/ gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unservic eable surplus material and stacking of serviceable material with in 50 meters lead as directed by the Engineer-in-Charge. 1280 PJEDIS1237: Disposal of building rubbish/ malba/ similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by the Engineer-in-Charge, beyond 50 m initial lead, for all leads including all lifts involved. 1290 PJEDRA2505: Supplying and fixing C.I. cover 300x300 mm without frame for gully trap (standard pattern) the weight of cover to be not less than 4.5 Kg 1300 PJEDRA2506: Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality : 1310 PJEDRA2507: Light Duty-2.5 : 1320 PJEDRA2508: Rectangular shape 600x450 mm internal dimensions 1330 PJEDRA2509: Square shape 450 mm internal dimensions 1340 PJEDRA2510: Circular shape 450 mm internal diameter 1350 PJEDRA2511: Medium Duty-10 : 1360 PJEDRA2512: Square shape 450 mm internal dimensions 1370 PJEDRA2513: Circular shape 500 mm internal diameter 1380 PJEDRA2514: Heavy Duty-20 : 1390 PJEDRA2515: Circular shape 560 mm internal diameter 1400 PJEDRA2516: Extra Heavy Duty-35 : 1410 PJEDRA2517: Circular shape 560 mm internal diameter 1420 PJEDRA2518: Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both si des with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement and making necessary channels fo r the drain etc. complete : 1430 PJEDRA2519: For pipes 100 to 250 mm diameter 1440 PJEDRA2520: For pipes 250 to 300 mm diameter 1450 PJEDRA2521: For pipes 350 to 450 mm diameter 1460 PJEDRA2550: Providing and fixing self cleaning S.C.I. heavy quality Floor/ Nahani trap with 100mm diameter inlet and 100mm diameter outlet, 125mm C.P. brass grating (heavy type) with or without vent arm including cost of cutting and making good the walls and floor s, jointing with lead caulked joints, connecting with waste water pipe etc. complete in all respects inclusive of cost of all materi als, labour, tools, tackles etc. as per drawings, specifications and directions of the Engineer-in-Charge. 1470 PJEDRA2551: Providing and fixing 32mm diameter (Nominal Bore) brass ball valve of approved quality complete with high pressure coppe r floats, complete in all respects inclusive of cost of all materials, labour, tools, tackles, etc. complete as per specifications a nd directions of the Engineer-in-Charge. 1480 PJEDRA2553: Construction of second class brick masonary open surface drain (Size: 200mm wide & 200mm average depth) in cement mortar 1:4 laid over a bed of 150mm thick cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) i ncluding making haunches and providing 15mm thick cement plaster in CM 1:4 (1 cement : 4 coarse sand) with a floating coat of neat c ement inside and its top and exposed surfaces, including excavatioin, disposal of the surplus earth up to any lead and lift as per s tandard design and drawing, complete in all respects inclusive of cost of all labour, materials, carriages, excavation and refilling , curing etc., as per specifications and directions of the Engineer-in-Charge. 1490 PJEDRA2588: Pumping out water caused by springs, tidal or river seepage, broken water mains or drains and the like. [Note: Unit KL shall mean KILO LITRE] 1500 PJEDRA2589: Cleaning and desilting of gully trap chamber, including removal of rubbish mixed with earth etc. and disposal of same, a ll as per the directions of Engineer-in-Charge. 1510 PJEDRA2590: Cleaning of chocked sewer line by diesel running vehicle mounting hydraulic operated high pressure suction cum jetting s ewer cleaning machine fitted with pump having 4000 litres suction capacity and 6000 litres water jetting tank capacity including ski lled operator, supervising engineer etc. for cleaning and partial desilting of manholes and dechocking of sewer lines. Dechocking an d flushing of sewer line from one manhole to another by high pressure jetting system of 2200 PSI for sewer line from 150 mm dia up t o 300 mm dia for all depth. 1520 PJEEAR0002: Earth work in surface excavation (not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan) i n all kinds of soil including getting out and disposal of excavated earth up to all lead and lift, as directed by the Engineer-in-Ch arge. 1530 PJEEAR0004: Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas including trimming of sides of the trenches, dressing, ramming and levelling the bottom of the trenches correct to level, grade etc. including filling in sid es of foundation trenches, plinth etc. with the excavated earth available and/or depositing the excess earth within station area l imits, in layers not exceeding 20 cms. thick, consolidating each deposited layer by ramming, watering, dressing to level and grade , complete in all respects inclusive of cost of all labour, materials, tools, tackles etc. as per drawings, specifications and direc tion of Site Engineer. 1540 PJEEAR0005: In all kinds of soil 1550 PJEEAR0006: In Ordinary rock 1560 PJEEAR0009: Supplying and filling selected earth/ moorum (excluding black cotton soil) from Contractors own borrow areas including royalty, with all leads and lifts in trenches, plinth, sides of foundation etc. including watering, compacting in layers not exceed ing 20cm thickness, complete in all respects inclusive of cost of all labour, materials, tools, tackles etc. as per drawings, specif ications and direction of Site Engineer. 1570 PJEEAR0011: Supplying and filling coarse sand under floors, in foundations and plinth including cost-of sand, royalty, transportatio n, loading , unloading, spreading in layers not exceeding 20 cm., watering, ramming, compacting, dressing and levelling etc. compl ete in all respects inclusive of cost of all labour, materials, tools, tackles etc. as per drawings, specifications and direction of Site Engineer. 1580 PJEEAR0013: Supplying all labour, materials, tools, chemicals, spray pumps etc. for making pre-constructional anti-termite treatment & creating a continuous chemical barrier under & all round the column pits, wall trenches, top surface of plinth filling, junction of wall & floor, along the exterior perimeter of the building, complete in all respects inclusive of cost of all labour, materials, tools, tackles etc. as per drawings, specifications and direction of Site Engineer. [Note: Total plinth area of the building shall be measured for payment]. 1590 PJEEAR0014: Supplying chemical emulsion (Chlorpyriphos/ Lindane emulsifiable concentrate of 20%) in sealed containers including deli very as specified. 1600 PJEEAR0015: Diluting and injecting chemical emulsion (Chlorpyriphos/ Lindane E.C. 20% with 1% concentration) for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : 1610 PJEEAR0016: Along external wall where the apron is not provided using chemical emulsion @ 7.5 litres/ sqm of the vertical surface of the substructure to a depth of 300 mm including excavation channel along the wall & rodding etc. complete : 1620 PJEEAR0017: Along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc. : 1630 PJEEAR0020: Treatment at points of contact of wood work by chemical emulsion Chlorpyriphos/ Lindane (in oil or kerosene based soluti on) @ 0.5 litres per hole by drilling 6 mm dia holes at downward angle of 45 degree at 150 mm centre to centre and sealing the same : 1640 PJEEAR0021: Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measu red at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared. 1650 PJEEAR0022: Clearing grass and removal of the rubbish up to a distance of 50 m outside the periphery of the area cleared. 1660 PJEEAR0023: Felling trees of the girth (measured at a height of 1 m above ground level), including cutting of trunks and branches, r emoving the roots and stacking of serviceable material and disposal of unserviceable material : 1670 PJEEAR0024: Beyond 30 cm girth upto and including 60 cm girth 1680 PJEEAR0025: Beyond 60 cm girth upto and including 120 cm girth 1690 PJEEAR0026: Beyond 120 cm girth upto and including 240 cm girth 1700 PJEEAR0027: Above 240 cm girth 1710 PJEEAR0028: Disposal of moorum/ building rubbish/ malba/ similar unserviceable, dismantled or waste material by mechanical transport including loading, transporting, unloading to designated location/ approved municiple dumping ground for lead up to 10 Km and for a ll lifts, complete as per directions of the Engineer-in-Charge. [Note: This item shall also be applicable in urban areas having dire ctions for restricted hours for movement/ plying of load carrying motor vehicles of 3.5 cum or more.] 1720 PJEEAR0030: Excavating trenches by mechinical / manual means of required width in all kinds of soil for pipes, cables, etc. includin g excavation for sockets, and dressing of sides, ramming of bottoms, for all depth, including getting out the excavated soil, and th en returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil, all work up to any lead & lift as directed by the Engineer-in-Charge : 1730 PJEEAR0031: Pipes, cables etc. not exceeding 80 mm dia. 1740 PJEEAR0032: Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia 1750 PJEEAR0033: Pipes, cables etc. exceeding 300 mm dia but not exceeding 600 mm 1760 PJEEAR0034: Excavating trenches of required width in ordinary rock for pipes, cables, etc. including excavation for sockets, getting out the excavated materials, returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. , stacking servicable materials for measurements and disposal of unservicable materials, all work up to any lead & lift as directed by the Engineer-in-Charge : 1770 PJEEAR0035: Trench depth upto 1.5m : 1780 PJEEAR0036: Pipes, cables etc. not exceeding 80 mm dia 1790 PJEEAR0037: Pipes, cables etc. exceeding 80 mm dia but not exceeding 300 mm dia 1800 PJEEAR0038: Pipes, cables exceeding 300 mm dia but not exceeding 600 mm dia 1810 PJEEAR0039: Trench depth exceeding 1.5 m but not exceeding 3 m: 1820 PJEEAR0040: Pipes, cables etc. exceeding 80 mm dia but not exceeding 300 mm dia 1830 PJEEAR0041: Pipes, cables exceeding 300 mm dia but not exceeding 600 mm dia 1840 PJEEAR0042: Trench depth exceeding 3 m but not exceeding 4.5 m: 1850 PJEEAR0043: Pipes, cables exceeding 300 mm dia but not exceeding 600 mm dia 1860 PJEEAR0066: Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceedin g 20 cm in depth, consolidating each deposited layer by ramming and watering, all works up to any lead and lift 1870 PJEFIN0898: CEMENT PLASTER (IN FINE SAND) : 1880 PJEFIN0899: 12 mm cement plaster of mix : 1890 PJEFIN0900: 1:4 (1 cement : 4 fine sand) 1900 PJEFIN0901: 1:6 (1 cement : 6 fine sand) 1910 PJEFIN0905: 20 mm cement plaster of mix : 1920 PJEFIN0906: 1:4 (1 cement : 4 fine sand) 1930 PJEFIN0907: 1:6 (1 cement : 6 fine sand) 1940 PJEFIN0908: CEMENT PLASTER (IN COARSE SAND) : 1950 PJEFIN0909: 12 mm cement plaster of mix : 1960 PJEFIN0910: 1:4 (1 cement : 4 coarse sand) 1970 PJEFIN0911: 1:6 (1 cement : 6 coarse sand) 1980 PJEFIN0915: 20 mm cement plaster of mix : 1990 PJEFIN0916: 1:4 (1 cement : 4 coarse sand) 2000 PJEFIN0917: 1:6 (1 cement : 6 coarse sand) 2010 PJEFIN0918: CEMENT PLASTER WITH A FLOATING COAT OF NEAT CEMENT 2020 PJEFIN0919: 12 mm cement plaster finished with a floating coat of neat cement of mix : 2030 PJEFIN0920: 1:3 (1 cement : 3 fine sand) 2040 PJEFIN0921: 1:4 (1 cement : 4 fine sand) 2050 PJEFIN0925: Cement plaster 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement : 2060 PJEFIN0926: 12 mm cement plaster 2070 PJEFIN0927: 20 mm cement plaster 2080 PJEFIN0942: Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufactu rers [Note: Unit BAG shall mean PER BAG OF 50 KG CEMENT USED IN THE MIX). 2090 PJEFIN0943: Extra for plastering exterior walls of height more than 10 m from ground level for every additional height of 3 m or par t thereof. 2100 PJEFIN0944: Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and s mooth complete. 2110 PJEFIN0945: Providing & fixing galvanized chicken wire net 20 Gauge, 20 mm mesh size in plastering work at the junction of RCC Colum ns/ Beams brickwork as directed by the Engineer-in-Charge. 2120 PJEFIN0963: Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved ma nufacturer and of required shade and colour all complete to achieve even shade and colour :New work (two or more coats) over and inc luding water thinnable priming coat with cement primer having VOC content less than 50 gram/litre 2130 PJEFIN0964: EXTERIOR FINISHING : 2140 PJEFIN0965: Finishing walls with water proofing cement paint of required shade : New work (Two or more coats applied @ 3.84 Kg/10 sq m) 2150 PJEFIN0966: Finishing walls with textured exterior paint of required shade New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm 2160 PJEFIN0967: Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.9 kg/10 sqm) 2170 PJEFIN0968: Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade : New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.9 kg/10 sqm) 2180 PJEFIN0969: Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifica tions : 2190 PJEFIN0970: Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of Special primer applied @ 0.75 ltr/10 sqm 2200 PJEFIN0971: Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/10 sqm of approved brand and manufacture. 2210 PJEFIN0972: Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm ov er an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture. 2220 PJEFIN0973: Finishing walls with ready mixed Premium acrylic emulsion paint (Company Depot Tinted) having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade with silicon ad ditives: New work (Two or more coats applied @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm. 2230 PJEFIN0974: Applying priming coat : 2240 PJEFIN0975: With ready mixed aluminium primer of approved brand and manufacture on resinous wood and plywood 2250 PJEFIN0976: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works 2260 PJEFIN0977: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel work (second coat) 2270 PJEFIN0978: Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturers specification s including appropriate priming coat, preparation of surface, etc. complete : 2280 PJEFIN0979: On steel work 2290 PJEFIN0980: On concrete work 2300 PJEFIN0981: Painting (two or more coats) on rain water, soil, waste and vent pipes and fittings with black anticorrosive bitumastic paint of approved brand and manufacture, over and including a priming of ready mixed zinc chromate yellow primer on new work : 2310 PJEFIN0982: 75 mm diameter pipes 2320 PJEFIN0983: 100 mm diameter pipes 2330 PJEFIN0984: 150 mm diameter pipes 2340 PJEFIN0985: Painting with oil type wood preservative of approved brand and manufacture : New work (two or more coats) 2350 PJEFIN0986: Providing and applying two coats of fire retardant paint on cleaned wood/ ply surface @ 3.5 sqm per litre per coat inclu ding preparation of base surface as per recommendations of manufacturer to make the surface fire retardant. 2360 PJEFIN0987: Coal tarring two coats on new work using 0.16 Litre and 0.12 Litre coal tar per sqm in the first coat and second coat re spectively. 2370 PJEFIN0988: Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work 2380 PJEFIN0989: Painting with aluminium paint of approved brand and manufacture to give an even shade : Two or more coats on new work 2390 PJEFIN0990: Painting with black anti-corrosive bitumastic paint of approved brand and manufacture to give an even shade : Two or mor e coats on new work 2400 PJEFIN0991: Varnishing with varnish of approved brand and manufacture : 2410 PJEFIN0992: Two or more coats of glue sizing with copal varnish over an under coat of flatting varnish 2420 PJEFIN0993: Two or more coats glue sizing with spar varnish or an under coat of flatting varnish 2430 PJEFIN0996: Lettering with black Japan paint of approved brand and manufacture. [Note: Unit EA shall mean PER LETTER PER CM HEIGH T]. 2440 PJEFIN0997: Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 2450 PJEFIN0998: Distempering with 1st quality acrylic distemper, having VOC (Volatile Organic Compound) content less than 50 grams/ litr e, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour : Old work (one or more coats) 2460 PJEFIN0999: Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour : 2470 PJEFIN1000: One coat 2480 PJEFIN1001: Two coats 2490 PJEFIN1002: Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour : 2500 PJEFIN1003: One coat 2510 PJEFIN1004: Two coats 2520 PJEFIN1005: Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content : 2530 PJEFIN1006: With ready mixed pink or grey primer on wood work (hard and soft wood) having VOC content less than 50 grams/ litre. 2540 PJEFIN1007: With water thinnable cement primer on wall surface having VOC content less than 50 grams/ litre. 2550 PJEFIN1008: Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repair s to scratches etc. complete. 2560 PJEFIN1009: Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. 2570 PJEFIN1010: Painting (one or more coats) on rain water, soil, waste and vent pipes and fittings with black anticorrosive bitumastic paint of approved brand and manufacture on old work : 2580 PJEFIN1011: 75 mm diameter pipes 2590 PJEFIN1012: 100 mm diameter pipes 2600 PJEFIN1013: 150 mm diameter pipes 2610 PJEFIN1014: Painting (one or more coats) on rain water, soil, waste and vent pipes and fittings with synthetic enamel paint of appro ved brand and manufacture and required colour on old work : 2620 PJEFIN1015: 75 mm diameter pipes 2630 PJEFIN1016: 100 mm diameter pipes 2640 PJEFIN1017: 150 mm diameter pipes 2650 PJEFIN1018: Painting with oil type wood preservative of approved brand and manufacture : Old work (one or more coats) 2660 PJEFIN1019: Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : One or more coats on old work 2670 PJEFIN1020: Painting with aluminium paint of approved brand and manufacture to give an even shade : One or more coats on old work 2680 PJEFIN1021: Painting with black anti-corrosive bitumastic paint of approved brand and manufacture to give an even shade : One or mor e coats on old work 2690 PJEFIN1022: French spirit polishing : One or more coats on old work 2700 PJEFIN1023: Polishing on wood work with ready made wax polish of approved brand and manufacture : Old work 2710 PJEFIN1024: Re-lettering with black Japan paint of approved brand and manufacture. [Note: Unit EA shall mean PER LETTER PER CM HE IGHT]. 2720 PJEFIN1025: Painting (one or more coats) with black Japan paint of approved brand and manufacture to give an even shade. 2730 PJEFIN1026: Finishing walls with water proofing cement paint of required shade : 2740 PJEFIN1027: Old work (one or more coats applied @ 2.20 kg/10 sqm) over priming coat of primer applied @ 0.80 litrs/10 sqm complete i ncluding cost of Priming coat. 2750 PJEFIN1028: Old work (one or more coats applied @ 2.20 kg/10 sqm) complete. 2760 PJEFIN1029: Finishing walls with textured exterior paint of required shade 2770 PJEFIN1030: Old work (Two or more coats on existing cement paint surface applied @ 3.28 ltr/10 sqm. 2780 PJEFIN1031: Old work (One or more coats) applied @ 1.82 ltr/10 sqm. 2790 PJEFIN1032: Finishing walls with Acrylic Smooth exterior paint of required shade : 2800 PJEFIN1033: Old work (Two or more coat applied @ 1.67 ltr/10 sqm) on existing cement paint surface. 2810 PJEFIN1034: Old work (One or more coat applied @ 0.90 ltr/10 sqm) 2820 PJEFIN1035: Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade : 2830 PJEFIN1036: Old work (Two or more coats applied @ 1.43 ltr/ 10 sqm) over existing cement paint surface. 2840 PJEFIN1037: Old work (one or more coats applied @ 0.83 ltr/10 sqm) 2850 PJEFIN1038: Varnishing with varnish of approved brand and manufacture : 2860 PJEFIN1039: One or more coats with copal varnish 2870 PJEFIN1040: One or more coats with spar varnish 2880 PJEFIN1041: Melamine polishing on wood work (one or more coat). 2890 PJEFIN1042: Varnishing with flatting varnish of approved brand and manufacture one or more coats on old work. 2900 PJEFIN1043: Providing Plaster of Paris coating on ceiling as per approved design complete in all respects inclusive of cost of all l abour, materials, tools, tackles etc. as per specifications and directions of the Engineer-in-Charge. 2910 PJEFLO0706: FLOORING : 2920 PJEFLO0707: Brick on edge flooring with bricks of class designation 7.5 on bed of 12 mm cement mortar, including filling the joint s with same mortar, with common burnt clay non modular bricks : 2930 PJEFLO0708: 1:4 (1 cement : 4 coarse sand) 2940 PJEFLO0709: 1:6 (1 cement : 6 coarse sand) 2950 PJEFLO0710: Dry brick on edge flooring in required pattern with bricks of class designation 7.5 on a bed of 12 mm mud mortar, includ ing filling joints with sand, with common burnt clay non modular bricks. 2960 PJEFLO0711: Supplying and laying flat brick soling in foundation trench, in floors, garages, sumps, etc., with bricks of class desig nation 50 laid to proper slope, level and grade etc. filling of the joints with sand etc. complete in all respects inclusive of cost of all labour, materials, tools, tackles etc. as per drawings, specifications and directions of the Engineer-in-Charge. 2970 PJEFLO0712: Providing and laying cement concrete flooring 25 mm thick of mix 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggreg ates 12.5 mm nominal thickness), laid monolithically over base of concrete in panels at all locations and heights including treads o f steps, nosing, landing slab etc. and finished with a floating coat of neat cement @ 2.20 Kg of cement per sqm of flooring, supplyi ng and fixing 1.5 mm thick aluminium strips for full depth, chequering in floor finish if required, rounding, sloping, curing, finis hing, preparation of slab, steps, etc., complete in all respects inclusive of cost of all labour, materials, tools, tackles etc. as per drawings, specifications and directions of the Engineer-in-Charge. [Note: Payment for base concrete shall be made under relevant item]. 2980 PJEFLO0713: 40 mm thick cement concrete Flooring with P.C.C. of grade mix 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of step s etc. complete : 2990 PJEFLO0714: Providing and laying 52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener c onsisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume, hardening compound mixed @ 2 li tre per 50 kg of cement or as per manufacturers specifications. This includes cost of cement slurry, but excluding the cost of nosi ng of steps etc. complete. 3000 PJEFLO0715: 62 mm thick cement concrete flooring with concrete hardener topping, under layer 50 mm thick cement concrete 1:2:4 (1 ce ment : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 ( 1 cement hardener mix : 2 graded stone aggregate, 6mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cemen t or as per manufacture’s specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. comple te. 3010 PJEFLO0716: Providing and laying 52 mm thick cement concrete flooring with metallic hardner topping, under layer of 40 mm thick ceme nt concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer of 12 mm thick metallic con crete hardner consisting of mix 1:2 (1 cement : 2 stone aggregate 6 mm nominal size) by volume with which metallic hardening compoun d such as IRONITE NO. 1 of IRONITE CO. OF INDIA LTD. or aproved equivalent mixed in the ratio 4:1 (4 parts of cement : 1 part of met allic floor hardening compound of approval quality) by weight, inclusive of cost of finishing, labour, material, equipment, etc. as per specifications and directions of the Engineer-in-Charge. 3020 PJEFLO0722: TILE FLOORING : 3030 PJEFLO0723: Chequered precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement : 4 coarse sand) : 3040 PJEFLO0724: Light shade pigment using white cement 3050 PJEFLO0725: Medium shade pigment using 50% white cement 50% Grey cement 3060 PJEFLO0726: Dark shade pigment using ordinary cement 3070 PJEFLO0727: Ordinary cement without any pigment 3080 PJEFLO0728: Providing and fixing 10 mm thick acid and/or alkali resistant tiles of approved make & colour using acid and/or alkali r esisting mortar bedding and filling joints with acid and/or alkali resisting cement as per IS:4457, all complete as per specifcation s and directions of the Engineer-in-Charge : 3090 PJEFLO0729: In flooring on a bed of 10 mm thick mortar 1:4 (1 acid and/or alkali resistant cement : 4 coarse sand) : 3100 PJEFLO0730: In dado/ skirting on 12 mm thick mortar 1:4 (1 acid and/or alkali resistant cement : 4 coarse sand) : 3110 PJEFLO0731: MARBLE STONE FLOORING : 3120 PJEFLO0732: Marble stone flooring with 18 mm thick marble stone, as per sample of marble approved by the Engineer-in-Charge, over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with grey cement slurry, including rubbing and polishing complete with : 3130 PJEFLO0733: Makrana White Second Quality 3140 PJEFLO0734: Raj Nagar Plain 3150 PJEFLO0735: Agaria White 3160 PJEFLO0736: Black Zebra 3170 PJEFLO0737: Udaipur Green Marble 3180 PJEFLO0738: Pink Plain Marble 3190 PJEFLO0742: Providing and laying machine cut, mirror polished, 18 mm thick Italian Marble Stone slab (Perlato, Rosso verona, Fire Re d or Dark Emperadore, etc.) flooring laid in required pattern in linear portion of the building all complete as per architectural dr awings, with 18 mm thick stone slab laid over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jo inted with white cement slurry @ 4.4 Kg/sq.m., including pointing with white cement slurry admixed with pigment to match the marble shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. 3200 PJEFLO0743: Providing and laying machine cut, mirror polished Marble stone flooring, in required design (Simple geometrical, abstrac t etc.) and in patterns in combination with Italian marble stone slabs (Perlato, Rosso verona, Fire Red or Dark Emperadore, etc.) of different colours, shades and finished surface texture etc., in linear portions of the building, all complete as per the architectu ral drawings, with 18 mm thick stone slab laid over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with white cement slurry @ 4.4 Kg/sq.m. including pointing with white cement slurry admixed with pigment to match the ma rble shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge : 3210 PJEFLO0744: Providing and laying natural Rajnagar White Marble tile strips 50 mm wide in flooring/ stairs laid over 20 mm thick ceme nt mortar 1:3 (1 cement : 3 coarse sand) including grouting the joints with white cement and matching pigment shade, cutting etc. as per manufacturers recommendation complete in all respects inclusive of cost of all labour, materials, tools, tackles etc. as per d rawings, specifications and directions of the Engineer-in-Charge. (Minimum length of strip shall be 600 mm). 3220 PJEFLO0745: GRANITE STONE FLOORING : 3230 PJEFLO0746: Providing and laying flamed finish Granite stone slab (Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent) floori ng in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointe d with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and poli shing etc. all complete as specified and as directed by the Engineer-in-Charge. 3240 PJEFLO0747: Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear p ortions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base o f cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed wit h pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer- in-Charge. 3250 PJEFLO0748: Polished Granite stone slab of colour Black, Cherry/Ruby Red or equivalent 3260 PJEFLO0749: Polished Granite stone slab of all colour and texture except Black, Cherry/Ruby Red 3270 PJEFLO0750: Providing and laying natural granite stone tile strips 50 mm wide in flooring of approved shade laid over 20 mm thick ce ment mortar 1:4 (1 cement : 4 coarse sand) including grouting the joints with white cement and matching pigment shade, cutting etc. as per manufacturers recommendation complete in all respects inclusive of cost of all labour, materials, tools, tackles etc. as per drawings, specifications and directions of the Engineer-in-Charge. (Minimum length of strip shall be 600 mm). 3280 PJEFLO0761: VITRIFIED FLOOR TILES : 3290 PJEFLO0762: Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the Manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved make, in all colours and shades, laid on 20 mm thick cement mort ar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 Kg/sq.m. including grouting the joints with white cement a nd matching pigments etc., complete : 3300 PJEFLO0763: Size of Tile 500x500 mm 3310 PJEFLO0764: Size of Tile 600x600 mm 3320 PJEFLO0765: Size of Tile 800x800 mm 3330 PJEFLO0766: Size of Tile 1000x1000 mm 3340 PJEFLO0767: Providing and laying Vitrified tiles in floor with different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS:15477, in average 6 mm thickness, includin g grouting of joints. [Note: Payment for grouting of joints shall be made separately] : 3350 PJEFLO0768: Size of Tile 500x500 mm 3360 PJEFLO0769: Size of Tile 600x600 mm 3370 PJEFLO0770: Size of Tile 800x800 mm 3380 PJEFLO0771: Size of Tile 1000x1000 mm 3390 PJEFLO0772: Providing and laying Double Charge Vitrified Tiles (polished finish) of specified sizes (thickness to be specified by th e Manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacture, in all colours an d shades, laid on 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 Kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only. L aying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, levelling system and rubber mallet for placing the tiles gently and easily : 3400 PJEFLO0773: Size of Tile 600 x 600 mm 3410 PJEFLO0774: Size of Tile 600 x 1200 mm 3420 PJEFLO0775: Size of Tile 800 x 800 mm 3430 PJEFLO0776: Size of Tile 800 x 1600 mm 3440 PJEFLO0777: Size of Tile 1000 x 1000 mm 3450 PJEFLO0778: Providing and laying Glazed Vitrified Tiles (polished finish) of specified sizes (thickness to be specified by the Manuf acturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacture, in all colours and shade s, laid on 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 Kg/sqm including groutin g the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only. Laying o f tiles will be done with the notch trowel, plier, wedge, clips of required thickness, levelling system and rubber mallet for placin g the tiles gently and easily : 3460 PJEFLO0779: Size of Tile 600 x 600 mm 3470 PJEFLO0780: Size of Tile 600 x 1200 mm 3480 PJEFLO0781: Size of Tile 800 x 800 mm 3490 PJEFLO0782: Size of Tile 800 x 1200 mm 3500 PJEFLO0783: Size of Tile 1200 x 1200 mm 3510 PJEFLO0784: Providing and laying Glazed Vitrified Tiles (Matt/ Antiskid finish) of specified sizes (thickness to be specified by the Manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacture, in all colours and shades, laid on 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 Kg/sqm including g routing the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only. La ying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, levelling system and rubber mallet for placing the tiles gently and easily : 3520 PJEFLO0785: Size of Tile 600 x 600 mm 3530 PJEFLO0786: Size of Tile 600 x 1200 mm 3540 PJEFLO0787: Size of Tile 800 x 800 mm 3550 PJEFLO0788: Size of Tile 800 x 1200 mm 3560 PJEFLO0789: Size of Tile 1200 x 1200 mm 3570 PJEFLO0790: Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorpti on less than 0.08 % and conforming to IS:15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm th ick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 Kg/sq.m. including grouting the joint with white cement & matching pigments etc. complete : 3580 PJEFLO0791: Size of Tile 500x500 mm 3590 PJEFLO0792: Size of Tile 600x600 mm 3600 PJEFLO0793: Size of Tile 800x800 mm 3610 PJEFLO0794: Size of Tile 1000x1000 mm 3620 PJEGEN2809: GENERAL WORKS : 3630 PJEGEN2816: Supply, installation, testing & commissioning of Turbo Roof Air Ventilators of Fan Size- 24 inch (neck/ throat dia.), Ve ntilator Diameter- 30 inch, Ventilator Base (FRP)- standard width 1.8m x dome height 750mm, Opening for ventilation dome- 860mm x 68 0mm x 608mm, thickness 2mm etc. complete in all respects and as per specifications and directions of the Engineer-in-Charge. 3640 PJEGEN2821: Providing and erecting 2.0 metre high temporary barricading at site; each panel of size 2.5m x 2.0m made of 40x40x6mm an gle iron or 50x50x3mm hollow MS tube posts/ horizontal members/ bracings covered with 1.63mm thick MS Sheet. The steel shall be fixe d with 30x5mm MS flat by suitable welding/ riveting. The panels shall be made so that gap of 50cm above the ground is available maki ng overall height as 2.5m. MS channel ISLC75 @ 5.70 kg/m, 50cm long shall be provided at the bottom having oval shaped holes of size 50x25mm at both ends with 50cm long MS angle 40x40x6mm bracing. Suitable arrangement shall be made to fix the barricading to avoid from overturning by providing 250mm long expansion fasteners at both ends. The work shall be executed as per drawing/ direction of E ngineer-in-Charge which includes writing and painting, arrangement for traffic diversion such as traffic signals during construction at site for day and night, glow lamps, reflective signs, marking, flags, caution tape as directed by the Engineer-in-Charge. The ba rricading provided shall be retained in position at site continuously including shifting of barricading from one location to another location as many times as required during the execution of the entire work till its completion. Rate include its maintenance for da mages, painting, all incidentals, labour materials, equipments and works required to execute the job. The barricading shall not be r emoved without prior approval of the Engineer-in-Charge. [Note: One time payment shall be made for providing barricading from start of work till completion of work including shifting. The barricading provided shall remain to be the property of the contractor on co mpletion of the work]. 3650 PJEGEN2824: Providing and laying Non-Woven Geo Textile Mat NW 300 made from high quality polypropylene fibres having mass of 300 gra ms/ SQ.M of GAYATRI or approved equivalent make inclusive of cost of all labour, materials, tools, tackles etc. as per manufacturer s recommendations and directions of the Engineer-in-Charge. 3660 PJEHOR2827: HORTICULTURE & LANDSCAPING : 3670 PJEHOR2828: Supplying and stacking of good earth at site including royalty and carriage up to any lead complete. [Note: Volume of ea rth measured in stacks will be reduced by 20% for payment]. 3680 PJEHOR2829: Supplying and stacking sludge at site including royalty and carriage up to any lead complete. [Note: Volume of sludge me asured in stacks will be reduced by 8% for payment]. 3690 PJEHOR2830: Supplying and stacking of well decayed cattle manure at site including royalty and carriage up to any lead complete. [No te: Volume of cattle manure measured in stacks will reduced by 8% for payment]. 3700 PJEHOR2835: Mixing earth and sludge or manure in the required proportion specified or directed by the Engineer-In-Charge. 3710 PJEHOR2836: Spreading of sludge, dump manure and/or good earth in required thickness including removal of debris/ un-wanted material , consolidation, dressing, levelling and watering etc. complete as per directions of the Engineer-in-Charge. [Note: Cost of sludge, dump manure and/or good earth shall be paid separately under relevant item of SOR]. 3720 PJEHOR2837: Filling mixture of earth and sludge or manure in the desired proportion in trenches, flooding with water and leveling. [ Note: Cost of supplying earth and sludge or manure and mixing shall be paid separately under relevant items of SOR]. 3730 PJEHOR2838: Trenching in ordinary soil up to a depth of 60 cm including removal and stacking of serviceable materials and then dispo sing of surplus soil, by spreading and neatly levelling within a lead of 50 m and making up the trenched area to proper levels by fi lling with earth or earth mixed with sludge or/ and manure before and after flooding trench with water. [Note: The rate is excluding cost of imported earth, sludge or manure]. 3740 PJEHOR2839: Rough dressing the trenched ground including breaking clods. 3750 PJEHOR2840: Flooding the ground with water including making kiaries and dismantling the same. 3760 PJEHOR2841: Uprooting weeds from the trenched area after 10 to 15 days of its flooding with water including disposal of uprooted veg etation. 3770 PJEHOR2844: Uprooting rank vegetation and weeds by digging the area to a depth of 60 cm, removing all weeds and other growth with ro ots by forking repeatedly, breaking clods, rough dressing, flooding with water, uprooting fresh growths after 10 to 15 days and then fine dressing for planting new grass, including disposal of all rubbish with all leads and lifts. 3780 PJEHOR2845: Preparation of beds for hedging and shrubbery by excavating 60 cm deep and trenching the excavated base to a further dep th of 30 cm, refilling the excavated earth after breaking clods and mixing with sludge or manure in the ratio of 8:1 (8 parts of sta cked volume of earth after reduction by 20% : one part of stacked volume of sludge or manure after reduction by 8%), flooding with w ater, filling with earth if necessary, watering and finally fine dressing, leveling etc. including stacking and disposal of material s declared unserviceable and surplus earth by spreading and leveling as directed, within a lead of 50 m, lift up to 1.5 m complete. [Note: Cost of sludge, manure or extra earth shall be paid for separately under relevant item of SOR]. 3790 PJEHOR2846: Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts. [Note: Cost of m anure, sludge or extra good earth if needed shall be paid separately under relevant item of SOR]. 3800 PJEHOR2847: Holes 1.2 m diameter and 1.2 m deep 3810 PJEHOR2848: Holes 90 cm diameter and 90 cm deep 3820 PJEHOR2849: Holes 60 cm diameter and 60 cm deep 3830 PJEHOR2850: Holes 45 cm diameter and 45 cm deep 3840 PJEHOR2851: Supplying & Stacking of Selection No.1/ Doob Grass at site fresh & free from weeds having proper roots in green includin g loading, unloading, carriage and all taxes paid etc. complete as per directions of the Engineer-in-Charge. 3850 PJEHOR2852: Grassing with selection No. 1/ Doob grass including watering and maintenance of the lawn for 30 days or more till the gr ass forms a thick lawn, free from weeds and fit for mowing including supply and filling of good earth, if required during maintenanc e period. [Note: The grass and good earth shall be paid for separately under relevant item of SOR] : 3860 PJEHOR2853: In rows 5 cm apart in both directions 3870 PJEHOR2854: With grass Turf 3880 PJEHOR2855: Providing and laying Neelgiri/ Mexican grass turf with earth 50mm to 60mm thickness of existing ground prepared with pro per level and ramming with tools wooden (Dhurmos) and than rolling the surface with light roller make the surface smoothen and light waterning with sprinkler and maintenance for 30 days or more till the grass establish properly, complete as per direction of the En gineer-in-Charge. 3890 PJEHOR2856: Providing & laying Selection No. 1 grass turf with earth 50mm to 60mm thickness of existing ground prepared with proper level and ramming with required tools wooden and than rolling the surface with light roller make the surface smoothen and light wate ring the same maintenance for 30 days or more till the grass establish properly, complete as per direction of the Engineer-in-Charge . 3900 PJEHOR2857: Plantation of Trees, Shrubs and Hedges at site including watering and removal of unserviceable materials as per directio n of the Engineer-in-Charge (excluding cost of plant & water): 3910 PJEHOR2858: Tree Plant 3920 PJEHOR2859: Shrub Plant 3930 PJEHOR2860: Hedge Plant/ Ground Cover 3940 PJEHOR2861: Supply and planting sapling (not less than 45 cm in height and 60 cm centre to centre) of Casurina, Labrum, Gulmohar, As hokas, Bottle Palm, Bougenvilla, Hibiscus, Roses or other approved type of variety of plants, watering & maintenance for 30 days min imum complete in all respects inclusive of cost of all materials, labour, tools, tackles etc. as per specifications and directions o f the Engineer-in-Charge. 3950 PJEHOR2862: Providing Circular Cement Concrete pots of specified size, cast with cement concrete of nominal mix 1:2:4 (1 cement: 2 c oarse sand: 4 graded stone aggregate 6 mm nominal size), reinforced with 7 Nos (3 Nos horizontal & 4 Nos vertical “U“ shape) M.S. wi res of 3.5 mm dia as per design, including required form work, finishing with cement punning on exposed surface, curing for specifie d period and stacking in required rows & height, all complete as per direction of the Engineer-in-Charge. 3960 PJEHOR2863: Top inside diameter 35 cm, outer bottom diameter 25 cm, total height 35 cm with wall thickness of 25.4 mm 3970 PJEHOR2864: Top inside diameter 30 cm, outer bottom diameter 20 cm, total height 30 cm with wall thickness of 25.4 mm 3980 PJEHOR2873: Filling of the Polythene bags by mixture of good earth and manure in the ratio of 2:1 (2 part of Good Earth and 1 part o f the Manure) and placing the same at appropriate place including supply & providing Polythene bags, all complete as per direction o f the Engineer-in-Charge. [Note:The Good Earth & Manure shall be paid separately under relevant item of SOR]. 3990 PJEHOR2874: Polythene bags size 12.5 cm diameter & 17.5 cm height 4000 PJEHOR2890: Edging with common burnt clay F.P.S (non modular) bricks of class designation 7.5, laid dry length wise including requir ed excavation, refilling, consolidating with hand packing and spreading surplus earth neatly within any lead. 4010 PJEHOR2894: Providing & fixing of White River (Stone) Pebbles size of 2 to 2.50 dia in natural colour at site of work including lo ading, unloading, carriage and all taxes paid etc.and as per directions of the Engineer-in-Charge. 4020 PJEHOR2895: Providing and fixing of TUFLEX Garden Fencing Hexagonal Net or approved equivalent of green colour (Weight 510 (+/-8%) g rams/SQ.M) in width of 60 cm with bamboo of 90 cm length. The bamboo should be painted with green colour paint of approved brand and manufacture (two or more coats) and fixed 30 cm below ground level and 60 cm above ground level at a distance of 1.50 metres. The n et and bamboo should be binded with 2 mm G.I. wire at three places properly as per directions of the Engineer-in-Charge. 4030 PJEHOR2896: MAINTENANCE WORKS 4040 PJEHOR2897: Renovating lawns including weeding, cheeling the grass, forking the ground, top dressing with sludge or manure, mixing t he same with forked soil, watering and maintaining the lawn for 30 days or more till the grass forms a thick lawn free from weeds an d fit for mowing and disposal of rubbish as directed, including supplying good earth if needed but excluding the cost of sludge or m anure. [Note: The good earth shall be paid for separately under relevant item of SOR]. 4050 PJEHOR2898: Cutting of hedge/ edge including removing of cut material, cleaning, hoeing of hedge/ edge, bed watering, manuring and a pplying insecticides and fungicides etc. (excluding the cost of all materials) complete as per directions of the Engineer-in-Charge. [Note: Unit SQM shall mean PER SQM PER MONTH.] 4060 PJEHOR2899: Cutting of designer hedge/ edge including removing of cut material, cleaning, hoeing of hedge/ edge, bed watering, manur ing and applying insecticides and fungicides etc. (excluding the cost of materials) complete as per directions of the Engineer-in-Ch arge. [Note: Unit SQM shall mean PER SQM PER MONTH.] 4070 PJEHOR2903: Pruning, trimming, shaping of trees/ shrubs (height 15 feet above) and removal of cut materials up to 50m lead inclusi ve of all labour, T&P, materials etc. complete as per direction of the Engineer-in-Charge. [Note: Unit EA shall mean PER TREE]. 4080 PJEHOR2904: Providing and watering of Horticulture features i.e. lawn, tree, shrubs, hedge/ edge, ground cover etc. with irrigation water at the site of work. Watering shall be done through water tanker having 5000 litre capacity with one labour for watering inclu ding cost of water, filling of tanker, watering at site with all leads and lifts as per direction of the Engineer-in-Charge. [Note: Unit EA shall mean PER TRIP]. 4090 PJEHOR2905: Anti-termite treatment of trees by digging holes 30 cm deep & 4 cm dia, 6 to 7 holes around the tree using chemical emul sion (Chlorpyriphos 20% EC in the ratio of 1% concentration) at the rate of 1.5 liter per hole in two time or more application to ge t the trees free from termite infection, complete as per directions of the Engineer-in-Charge. [Note: Unit EA shall mean EACH TRE E]. 4100 PJEHOR2908: Cleaning and Sweeping of Lawn/ Garden area and keep it neat & clean by mechanized method/ manually, removimg litter, deb ris, picking of leaves, papers, plastic bottles etc. including disposal of collected waste in dustbin/ designated place, as per dire ction of the Engineer-in-Charge. [Note: All T&P, materials/ articles shall be provided by the Contractor]. 4110 PJEHOR2909: Removal of garden waste by TATA 407 or equivalent capacity vehicle including loading/ unloading, carriage up to 1.0 Km l ead & disposal at designated place etc. complete as per direction of the Engineer-in-Charge. [Note: Unit EA shall mean PER TRIP] . 4120 PJEMAS0143: MASONRY WORK : 4130 PJEMAS0144: Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in : 4140 PJEMAS0145: Cement mortar 1:4 (1 cement : 4 coarse sand) 4150 PJEMAS0146: Cement mortar 1:6 (1 cement : 6 coarse sand) 4160 PJEMAS0147: Brick work with common burnt clay modular bricks of class designation 7.5 in foundation and plinth in : 4170 PJEMAS0148: Cement mortar 1:4 (1 cement : 4 coarse sand) 4180 PJEMAS0149: Cement Mortar 1:6 (1 cement : 6 coarse sand) 4190 PJEMAS0150: Brick work with common burnt clay F.P.S. (non-modular) bricks of class designation 7.5 in superstructure above plinth le vel up to floor V level in all shapes and sizes in : 4200 PJEMAS0151: Cement mortar 1:4 (1 cement : 4 coarse sand) 4210 PJEMAS0152: Cement mortar 1:6 (1 cement : 6 coarse sand) 4220 PJERAI2738: Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required th ickness, for all leads & lifts, all complete as per directions of the Engineer-in-Charge. 4230 PJERAI2739: Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing lay er of boulders, in required thickness, for all leads & lifts, all complete as per directions of the Engineer-in-Charge. 4240 PJERAI2740: Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per directions of the Engineer-in-Charge. 4250 PJERAI2742: Providing and fixing factory made precast RCC perforated drain covers, having concrete of strength not less than M-25, o f size 1000x450x50 mm, reinforced with 8 mm dia four nos longitudinal & 9 nos. cross sectional T.M.T. hoop bars, including providing 50 mm dia perforations @ 100 to 125 mm c/c, including providing edge binding with M.S. flats of size 50 mm x 1.6 mm complete, all a s per directions of the Engineer-in-Charge. 4260 PJEREI0090: RCC (CAST IN-SITU) : 4270 PJEREI0091: Providing and laying structural reinforced cement concrete work (1:1.5:3) conforming to IS:456 (1 cement : 1.5 coarse sa nd : 3 graded stone aggregate 20 mm nominal size) at all heights and depth for construction of foundations, beams, columns, stairca ses, chajja,lintels, balconies, shelves, plain window sills, roof slabs, facia, canopies, fins, porch, water tank etc. including pro viding centering, shuttering, staging, scaffolding, form work etc compacting with mechanical vibrator, curing etc. complete in all respects inclusive of cost of all labour, materials, tools, tackles etc. as per drawings, specifications and direction of Site Engin eer. (Payment for Reinforcement shall be made as per relevant item of SOR). 4280 PJEREI0092: a) All work up to plinth level 4290 PJEREI0093: b) In superstructure at all floors up to floor five level, 4300 PJEREI0106: Steel reinforcement for R.C.C. workincluding initial straightening of coiled/uncoiled bars, removal of loose rust, cutti ng, bending to correct size & shape, binding with 18 gauge G.I. wire at each intersection and placing at any position, at any height and depth complete in all respects inclusive of cost of all labour, materials, tools, tackles etc. as per drawings, specifications and direction of Site Engineer. : Thermo-Mechanically Treated bars of grade Fe-500 D or more 4310 PJEREP1046: Repair to plaster of thickness 12 mm to 20 mm in patches of area up to 2.5 SQM including cutting the patch in proper sha pe, raking out joints, preparing and plastering the wall surface etc. complete, including disposal of rubbish at unobjectionable are a outside Ownders premises, all complete as per directions of the Engineer-in-Charge : 4320 PJEREP1047: With cement mortar 1:4 (1 cement : 4 fine sand) 4330 PJEREP1048: With cement mortar 1:4 (1 cement : 4 coarse sand) 4340 PJEREP1103: Providing and fixing double scaffolding system (cup lock type) on the exterior side, up to seven story height made with 40 mm dia M.S. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube ch allies, M.S. clamps and M.S. staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condi tion for the required duration as approved and removing it thereafter. The scaffolding system shall be stiffened with bracings, runn ers, connection with the building etc wherever required for inspection of work at required locations with essential safety features for the workmen etc. complete as per directions and approval of the Engineer-in-Charge. The elevational area of the scaffolding shal l be measured for payment purpose. The payment will be made once irrespective of duration of scaffolding. [Note: This item to be use d for maintenance work judicially, necessary deduction for scaffolding in the existing item to be done] 4350 PJEREP1108: Cutting holes of required size in brick masonry wall for fixing of exhaust fan including providing and fixing 300 mm dia PVC pipe conforming BIS-12818 and making good the same etc. complete as per the directions of Engineer-in-Charge. 4360 PJEREP1109: Dismantling W.C. Pan of all sizes including disposal of dismantled materials including malba all complete as per the dir ections of Engineer-in-Charge. 4370 PJEREP1113: Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer, 3 mm thick water proofing me mbrane, black finished reinforced with glass fibre matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufactured of density at 25°C, 0.87-0.89 kg/litre and viscocity 70-160 cps. Over the primer coat the layer o f membrane shall be laid using butane torch and sealing all joints etc., and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under : (a) Joint strength in longitudinal and transverse direction at 23°C as 350/3 00 N/5 cm. (b) Tear strength in longitudinal and transverse direction as 60/80N. (c) Softening point of membrane not less than 150°C . (d) Cold flexibility shall be up to -2°C when tested in accordance with ASTM, D-5147. The laying of membrane shall be got done thr ough the authorised applicator of the manufacturer of membrane. 4380 PJEREP1114: Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer, 3 mm thick water proofing me mbrane, black finished reinforced with non-woven polyester matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 l itre/sqm by the same membrane manufacture of density at 25°C, 0.87-0.89 kg/ litre and viscocity 70-160 cps. Over the primer coat the layer of membrane shall be laid using Butane Torch and sealing all joints etc, and preparing the surface complete. The vital physic al and chemical parameters of the membrane shall be as under : (a) Joint strength in longitudinal and transverse direction at 23°C a s 650/450N/5cm. (b) Tear strength in longitudinal and transverse direction as 300/250N. (c) Softening point of membrane not less tha n 150°C. (d) Cold flexibility shall be up to -2°C when tested in accordance with ASTM, D-5147. The laying of membrane shall be got d one through the authorised applicator of the manufacturer of membrane. 4390 PJEREP1115: Extra for covering top of membrane with Geotextile, 120 GSM non woven, 100% polyester of thickness 1 to 1.25 mm bonded t o the membrane with intermittent touch by heating the membrane by Butane Torch as per manufactures recommendation. 4400 PJEREP1116: STRUCTURAL REPAIR WORKS : 4410 PJEREP1117: Chipping of unsound/ weak concrete material from slabs, beams, columns etc. with manual Chisel and/or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning t he exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as p er directions of the Engineer-in-Charge : 4420 PJEREP1118: 75 mm average thickness 4430 PJEREP1119: 50 mm average thickness 4440 PJEREP1120: 25 mm average thickness 4450 PJEREP1121: Cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkali ne chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per directions of the Engineer-in-Charge : 4460 PJEREP1122: Bars up to 12 mm diameter 4470 PJEREP1123: Bars above 12 mm diameter 4480 PJEREP1124: Providing and applying anticorrosive treatment to exposed structural reinforcement with two coats of IPNET RB or equival ent with time interval of minimum 8-10 hours between each coat after the application of two coats of alkaline rust converting primer . The application shall be done by brush after cleaning existing reinforecement with wire/ rotary wire brush to make the surface fre e from loose material, dirt etc. and thoroughly washing with water and allowing it to dry inclusive of all materials, labour, equipm ent, etc. complete as per specifications and directions of the Engineer-in-Charge. The application of anticorrosive treatment shall be strictly as per technical specifications and directions of the Engineer-in-Charge. [Note: Unit M shall mean RUNNING METRE. Th e running metre of rebars shall be measured for payment purpose]. 4490 PJEREP1125: Drilling suitable holes in reinforced or plain cement concrete with power driven drill machine to a minimum depth of 100 mm up to 200 mm in RCC beams, lintels, columns and slabs to introduce steel bars for sunshades/ balconies including fixing the stee l bars in position using epoxy resin anchor grout of approved make but excluding the cost of reinforcement, all complete as per dire ctions of the Engineer-in-Charge : Up to and including 12 mm diameter 4500 PJEREP1126: Providing, mixing and applying bonding coat of approved adhesive on chipped portion of RCC as per specifications and dir ections of the Engineer-in-Charge complete in all respect : 4510 PJEREP1127: SBR Polymer (@ 10% of cement weight) modified cementitious bond coat @ 2.2 kg cement per sqm of surface area mixed with specified proportion of approved polymer. 4520 PJEREP1128: Epoxy bonding adhesive having coverage 2.20 sqm/kg of approved make. 4530 PJEREP1129: Providing, mixing and applying SBR polymer (of approved make) modified cement mortar in proportion of 1:4 (1 cement: 4 g raded coarse sand with polymer minimum 2% by wt. of cement used) as per specifications and directions of the Engineer-in-Charge. [No te: Measurement and Payment- The pre-measurement of thickness shall be done just after the surface preparation is completed and paym ent under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by soundi ng/ tapping with a blunt metal instrument and/or the 75 mm size cube crushing strength at the end of 28 days to be not less than 30 N/sq.mm] : 4540 PJEREP1130: 12 mm average thickness. 4550 PJEREP1131: 25 mm average thickness in 2 layers. 4560 PJEREP1132: 50 mm average thickness in 3 layers. 4570 PJEREP1140: Providing and injecting approved grout in proportion recommended by the manufacturer into cracks/ honey-comb area of con crete/ masonry by suitable gun/ pump at required pressure including cutting of nipples after curing etc. complete as per directions of the Engineer-in-Charge. [Note: The payment shall be made on the basis of actual weight of approved grout injected] : 4580 PJEREP1141: Stirrer mixed Acrylic Polymer of approved make (@ 2% of weight of cement used) modified cement slurry made with non shri nk compound in Concrete/ RCC work. 4590 PJEREP1142: Stirrer mixed SBR Polymer (of approved make) modified cement slurry made with Shrinkage Compensating Cement in Concrete/ RCC work. 4600 PJEREP1143: Epoxy injection grout in Concrete/ RCC work of approved make. 4610 PJEROA1249: Laying, spreading and compacting stone aggregate of specified sizes to WBM specifications in uniform thickness, hand pic king, rolling with 3 wheeled road/ vibratory roller 8-10 tonne capacity in stages to proper grade and camber, applying and brooming requisite type of screening/ binding material to fill up interstices of coarse aggregate, watering and compacting to the required de nsity. 4620 PJEROA1250: SURFACE DRESSING : 4630 PJEROA1251: Surface dressing on new surface with paving bitumen of grade VG-10 of approved quality using 2.25 Kg of bitumen per sqm with 1.65 cum of stone chippings 13.2 mm nominal size per 100 sqm of road surface, including consolidation with road roller of 6 to 8 tonne capacity etc. complete. 4640 PJEROA1252: Surface dressing on new surface in two coats with bitumen of grade VG-10 of approved quality using 1.8 kg of bitumen per sqm with 1.5 cum of stone chippings 13.2 mm nominal size per 100 sqm of road surface for first coat and 1.1 kg. of bitumen per sqm with 1.00 cu. metre of stone chippings 11.2 mm nominal size per 100 sqm of road surface for second coat, including consolidation of each coat separately with road roller of 6 to 8 tonne capacity etc. complete. 4650 PJEROA1253: Surface dressing on old surface with hot bitumen of grade VG-10 of approved quality using 1.95 kg of bitumen per sqm wit h 1.50 cum of stone chippings 11.2 mm nominal size per 100 sqm of road surface, including consolidation with road roller of 6 to 8 t onne capacity, etc. complete. 4660 PJEROA1254: Surface dressing one coat on new surface with bitumen of specified grade at a rate of 1.95 Kg/sqm of surface area with 1 .5 cum of stone chippings 13.2 mm nominal size per 100 sqm of road surface, including consolidation with road roller of 6 to 8 tonne capacity, etc. complete :Using Bitumen Emulsion (Minimum 50% bitumen content- RS grade conforming to IS:8887) 4670 PJEROA1255: Surface dressing one coat on old surface with bitumen of specified grade at the rate of 1.22 kg/ sqm of surface area wit h 1.10 cum of stone chippings 11.2 mm nominal size per 100 sqm of road surface, including consolidation with road roller of 6 to 8 t onne capacity etc. complete : Using Bitumen Emulsion (Minimum 50% bitumen content- RS grade conforming to IS:8887) 4680 PJEROA1285: SEAL COAT : 4690 PJEROA1286: Providing and laying seal coat of premixed fine aggregate (passing 2.36 mm and retained on 180 micron sieve) with bitume n using 128 kg of bitumen of grade VG-10 bitumen per cum of fine aggregate and 0.60 cum of fine aggregate per 100 sqm of road surfac e, including rolling and finishing with road roller all complete. [Note: This item to be operated only with the prior approval of th e Engineer-in-Charge]. 4700 PJEROA1298: PAINTING AREA / RUNWAY MARKING : 4710 PJEROA1299: Painting road surface marking with adequate nos of coats to give uniform finish with ready mixed road marking paint conf orming to IS:164, on bituminous surface in white/ yellow shade, including cleaning the surface of all dirt, scales, oil, grease and foreign material etc. complete 4720 PJEROA1300: New work (Two or more coats) 4730 PJEROA1301: Old work (One or more coats) 4740 PJEROA1309: Providing and fixing Glow Studs of size 100x20 mm made of heavy duty body shall be moulded ASA (Acrylic styrene Acrylore trite) or HIP (High impact polystyrene) or ABS having electronically welded micro-prismatic lens with abrasion resistant coating as approved by the Engineer-in-Charge. The glow stud shall support a load of 13635 kg tested in accordance with ASTM D4280. The slope o f retro-reflective surface shall be 35 (+/-5) degress to base. The reflective panels on both sides with at least 12 cm of reflective area up each side. The luminance intensity should be as per the specification and shall be tested as described in ASTM I: 809 as re commended in BS: 873 (Part-4):1973. The studs shall be fixed to the Road surface using the adhesive conforming to IS, as per procedu re recommended by the manufacturer complete and as per directions of the Engineer-in-Charge. 4750 PJEROA1315: Providing and applying 2.5 mm thick road marking strips (retro-reflective) of specified shade/ colour using hot thermopl astic material by fully/ semi automatic thermoplastic paint applicator machine fitted with profile shoe, glass beads dispenser, prop ane tank heater and profile shoe heater, driven by experienced operator on road surface including cost of material, labour, T&P, cle aning the road surface of all dirt, seals, oil, grease and foreign material etc. complete as per directions of the Engineer-in-Charg e and accordance with applicable specifications. 4760 PJEROA1359: Taking out existing kerb stones of all types from footpath/ central verge, including removal of mortar etc., disposal of unserviceable material to the dumping ground, for which payment shall be made separately and stacking of serviceable material withi n 50 metre lead as per directions of the Engineer-in-Charge. 4770 PJEROA1360: Taking out existing CC interlocking paver blocks from footpath/ central verge, including removal of rubbish etc., dispos al of unserviceable material to the dumping ground, for which payment shall be made separately and stacking of serviceable material within 50 metre lead as per directions of the Engineer-in-Charge. 4780 PJEROA1361: Laying old cement cocrete interlocking paver blocks of any design/ shape laid in required line, level, curvature, colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the directions of the Engineer-in-Charge. [Note: Old CC paver blocks shall be supplied by the department free of cost]. 4790 PJEROA1362: Laying at or near ground level old kerb stones of all types in position to the required line, level and curvature, joint ed with cement mortar 1:3 (1 cement : 3 coarse sand), including making joints with or without grooves (thickness of joints, except a t sharp curve, shall not be more than 5 mm), including making drainage opening wherever required etc. complete as per directions of the Engineer-in-Charge. [Notes: (1) Length of finished kerb edging shall be measured for payment. (2) Old kerb stones shall be suppl ied by the department free of cost.] 4800 PJEROO0824: THERMAL INSULATION: 4810 PJEROO0825: Providing and fixing thermal insulation of ceiling (under deck insulation) with Resin Bonded Fibre glass wool conforming to IS:8183, density 24 kg/cu.m., 50mm thick, wrapped in 200G Virgin Polythene bags, fixed to ceiling with metallic cleats (50x50x3 mm) @ 60 cm and wire mesh of 12.5 mm x 24 gauge wire mesh, for top most ceiling of building. 4820 PJEROO0826: Providing and fixing thermal insulation with Resin Bonded Fibre glass wool conforming to IS:8183, Density 16 Kg/cu.m., 5 0 mm thick, wrapped in 200G Virgin Polythene bags placed over existing false ceiling and held in position by criss-crossing G.I. wir e. 4830 PJEROO0827: Providing and fixing thermal insulation with Resin Bonded Fibre glass wool conforming to IS:8183 having density 24 Kg/cu .m., 50 mm thick, wrapped in 200G Virgin Polythene Bags fixed to wall with screw, rawl plug & washers and held in position by criss crossing G.I. wire etc. complete as per directions of the Engineer-in-Charge. 4840 PJEROO0828: Providing and fixing thermal insulation of ceiling (under deck insulation) with Resin Bonded Rockwool conforming to IS:8 183, density 48 Kg/cu.m., 50 mm thick, wrapped in 200G Virgin Polythene bags fixed to ceiling with metallic cleats (50x50x3 mm) @ 60 cm and wire mesh of 12.5 mm x 24 Gauge wire mesh, for top most ceiling of building. 4850 PJEROO0872: FALSE CEILING : 4860 PJEROO0873: Providing and fixing tiled false ceiling of specified materials size 595x595 mm in true horizontal level, suspended o n inter locking metal grid of hot dipped galvanized steel sections (galvanized @ 120 grams/sq.m., both side inclusive) consisting of main T runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, sp aced at 1200 mm center to center and cross T of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between m ain T at 600 mm center to center to form a grid of 1200x600 mm and secondary cross T of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of siz e 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/ making, opening for servi like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main T runners to be suspended from ceiling using G.I. slotted cleats of size 27x37x25x1.6 mm fixed to ceiling with 12.5 mm dia. and 50 mm long dash fasteners, 4 mm G.I. adjustable rods w ith galvanised butterfly level clips size 85x30x0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings a nd as directed by the Engineer-in-Charge : 4870 PJEROO0874: G.I. Metal Ceiling Lay in plain Tegular edge Global white color tiles of size 595x595 mm, and 0.5 mm thick with 8 mm dro p; made of G. sheet having galvanizing of 100 gms/sq.m. (both sides inclusive) and electro-statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending. 4880 PJEROO0875: G.I. Metal Ceiling Lay in perforated Tegular edge global white color tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made G.I. sheet having galvanizing of 100 gms/sq.m. (both sides inclusive) and 20% perforation area with 1.8 mm dia. holes and having NRC (Noise Reduction Coefficient) of 0.5, electro-statically polyester powder coated thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fiber acoustical fleece. 4890 PJEROO0876: 12.5 mm thick square edge PVC Laminated Gypsum Tile of size 595x595 mm, made of Gypsum plasterboard, manufactured from n atural gypsum as per IS:2095 (Part-1) and laminated with white 0.16 mm thick fire retardant PVC film on the face side and 12 micron metalized polyester on the back side with all edges sealed with the face side PVC film which goes around and wraps the edges and is bonded to the edges and the back side metalized polyester film so as to make the tile a completely sealed unit. 4900 PJEROO0877: 12.5 mm thick fully Perforated Gypsum Board tile made from plasterboard having glass fibre conforming to IS:2095 (Part-1 ), of size 595x595 mm, having perforation of 9.7x9.7 mm at 19.4 mm center to center with center borders of 48 mm and the side border s of 30 mm, backed with non woven tissue on the back side, having an NRC (Noise Reduction Coefficient) of 0.79, with 50 mm resin bon ded glass wool backing. 4910 PJESAN1368: SANITARY INSTALLATIONS : 4920 PJESAN1369: Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 l itre low level white P.V.C. dual flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming t o IS:7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : White vitreous china orissa pattern W.C. pan of size 580x440 mm with integral type foot rests 4930 PJESAN1370: Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litr e low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS:72 31, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : 4940 PJESAN1371: W.C. pan with ISI marked white solid plastic seat and lid. 4950 PJESAN1373: Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low lev el white vitreous china dual flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangemen t with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings a nd brackets, cutting and making good the walls and floors wherever required : 4960 PJESAN1374: W.C. pan with ISI marked white solid plastic seat and lid 4970 PJESAN1376: Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass union s and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever requir ed : 4980 PJESAN1377: One urinal basin with 5 litre white P.V.C. automatic flushing cistern 4990 PJESAN1378: Range of two urinal basins with 5 litre white P.V.C. automatic flushing cistern 5000 PJESAN1379: Range of three urinal basins with 10litre white P.V.C. automatic flushing cistern 5010 PJESAN1391: Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pat tern, including painting of fittings and brackets, cutting and making good the walls wherever require : 5020 PJESAN1392: White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps 5030 PJESAN1407: Providing and fixing Stainless Steel A ISI 304(18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : 5040 PJESAN1408: Kitchen sink with drain board : 5050 PJESAN1409: 510x1040 mm bowl depth 250 mm 5060 PJESAN1410: 510x1040 mm bowl depth 225 mm 5070 PJESAN1411: 510x1040 mm bowl depth 200 mm 5080 PJESAN1412: 510x1040 mm bowl depth 178 mm 5090 PJESAN1457: Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete : 5100 PJESAN1466: Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick har d board ground fixed to wooden cleats with C.P. brass screws and washers complete. 5110 PJESAN1473: Providing and fixing toilet paper holder : 5120 PJESAN1474: C.P. Brass 5130 PJESAN1665: Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour : 5140 PJESAN1666: Waste coupling 31 mm dia of 79 mm length and 62 mm breadth weighing not less than 45 gms. 5150 PJESAN1667: Waste coupling 38 mm dia of 83 mm length and 77 mm breadth, weighing not less than 60 gms. 5160 PJESAN1668: Providing and fixing PTMT Bottle Trap for Wash basin and sink : 5170 PJESAN1669: Bottle trap 31 mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of th e waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 gms. 5180 PJESAN1670: Bottle trap 38 mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of th e waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 263 gms. 5190 PJESAN1671: Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. 5200 PJESAN1672: Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wal l face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms. 5210 PJESAN1673: Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed f ittings arrangement of approved quality and colour : 5220 PJESAN1674: 450 mm long towel rail with total length of 495 mm, 78 mm width and effective height of 88 mm, weighing not less than 17 0 gms. 5230 PJESAN1675: 600 mm long towel rail with total length of 645 mm, 78 mm width and effective height of 88 mm, weighing not less than 19 0 gms. 5240 PJESTE0618: Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts, lock ing arrangement, stoppers, handles, including applying a priming coat of approved steel primer. 5250 PJESTE0619: Providing and fixing 1 mm thick M.S. sheet sliding-shutters, with frame and diagonal braces of 40x40x6 mm angle iron, 3 mm M.S. gusset plates at the junctions and corners, 25 mm dia pulley, 40x40x6 mm angle and T- iron guide at the top and bottom respe ctively, including applying a priming coat of approved steel primer. 5260 PJESTE0623: Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through t heir entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing n ecessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS:4454 (Part-1) and M.S. top cover of required thickness for rolling shutters : 5270 PJESTE0624: 80 x 1.25 mm M.S. laths with 1.25 mm thick top cover 5280 PJESTE0627: Providing and fixing ball bearing for rolling shutters. 5290 PJESTE0628: Extra for providing mechanical device chain and crank operation for operating rolling shutters : 5300 PJESTE0629: Exceeding 10.00 sq.m. and up to 16.80 sq.m. in the area 5310 PJESTE0630: Exceeding 16.80 sq.m. in area 5320 PJESTE0664: Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase rail ing and similar works, including applying priming coat of approved steel primer : 5330 PJESTE0665: M.S. Tube 5340 PJESTE0666: E.R.W. Tubes 5350 PJESTE0667: G.I. Pipes 5360 PJESTE0674: Providing and fixing Stainless Steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc. , of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of the Engineer-in-C harge. [Note: For payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nu ts, bolts, fasteners etc.] 5370 PJESTE0675: Providing & fixing fly proof wire gauze to windows, clerestory windows & doors with M.S. Flat 15x3 mm and nuts & bolts c omplete : 5380 PJESTE0676: Galvanised M.S. wire gauze with 0.63 mm dia wire and 1.4 mm aperture on both sides. 5390 PJESTE0677: Stainless Steel (Grade 304) wire gauze of 0.5 mm dia wire and 1.4 mm aperture on both sides. 5400 PJESTE0687: Supplying, fitting and fixing hot dip galvinised barbed line wire through holes in fencing posts (already made in the bo dy of the post), tightening and fixing the wire in tight condition with straining bolts (straining bolts at end post) including the cost of cutting and lapping joints, making holes, straining bolts, galvanised staples, binding wires etc. complete in all respects i nclusive of cost of all labour, materials, tools, tackles etc. as per drawings, specifications and directions of the Engineer-in-Cha rge. 5410 PJESTE0690: Supplying and placing in position 5.0 mm thick steel chequered plates over cable ducts, valve pits etc. including provis ion for lifting arrangements complete in all respects inclusive of cost of all labour, materials, tools, tackles etc. as per drawing s, specifications and directions of the Engineer-in-Charge. 5420 PJESTE0691: Supplying & fixing Pigeon Protection net of mesh 15 mm x 15 mm & Gauge SW14 in sheds including specials required for bol ting with tie members of truss, painted with two coats of synthetic enamel paint of over a coat of red oxide zinc chrome primer comp lete in all respects inclusive of cost of all labour, materials, tools, tackles etc. as per drawings, specifications and direction o f the Engineer-in-Charge. 5430 PJESTE0698: G.I. Barbed Wire Fencing with angle iron post placed at required distance embedded in cement concrete blocks, every 15th post, last but one end post and corner post shall be strutted on both sides and end post on one side only and provided with horizon tal lines and two diagonals interwoven with horizontal wires, of barbed wire weighing 9.38 Kg/100 m (minimum), between the two posts fitted and fixed with G.I. staples, turn buckles etc. complete. [Notes: (1) Cost of posts, struts, earth work and concrete work to be paid for separately. (2) Payment to be made per metre cost of total length of barbed wire used]. 5440 PJESTE0704: Supplying, fitting and fixing punched tape concertina spiral coil of 50 turns per coil having core wire of 2.6 mm diamet er made of high carbon spring steel of high tensile strength as per IS:4454 (Part-I, Grade-II) having minimum galvanising coating th ickness equivalent to 230 grams per square metre and low carbon steel strip of 0.5 mm thickness having a series of barbes punched al l along the length on both sides of the strip at regular interval as per IS:513, DD quality having minimum galvanising coating thick ness of 12 microns. Hardness of tape should be between 137-180 VPN (Victor Penetration Number). The coil should be clipped sufficien tly at regular intervals. The coil should not be stretched for more than 6.0 m length and the minimum diameter of the coil in the cl osed condition should not be less than 600 mm complete in all respects inclusive of cost of all labour, materials, tools, tackles et c. as per drawings, specifications and directions of the Engineer-in-Charge. 5450 PJESTE0705: Providing and fixing concertina coil fencing with punched tape concertina coil 600 mm dia 10 metre openable length (tota l length 90 m), having 50 nos rounds per 6 metre length, up to 3 m height of wall with existing angle iron Y shaped placed 2.4 m o r 3.00 m apart and with 9 horizontal R.B.T. reinforced barbed wire, stud tied with G.I. staples and G.I. clips to retain horizontal, including necessary bolts or G.I. barbed wire tied to angle iron, all complete as per the directions of Engineer-in-Charge, with re inforced barbed tape (R.B.T.) / Spring core (2.5 mm thick) wire of high tensile strength of 165 kg/ sq.mm with tape (0.52 mm thick) and weight 43.478 gm/ metre. [Note: Cost of M.S. angle, C.C. blocks shall be paid separately]. 5460 PJESTO0175: STONE WORK : 5470 PJESTO0176: RANDOM RUBBLE MASONRY : 5480 PJESTO0177: Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cem ent : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with : 5490 PJESTO0178: Cement mortar 1:6 (1 cement : 6 coarse sand) 5500 PJESTO0179: Random rubble masonry with hard stone in superstructure above plinth level and upto floor five level, including leveling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) at window sills, ceiling l evel and the like. 5510 PJESTO0180: Cement mortar 1:6 (1 cement : 6 coarse sand) 5520 PJEWAT1698: WATER SUPPLY : 5530 PJEWAT1699: CPVC PIPES : 5540 PJEWAT1700: Internal Work - Exposed on wall: Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stabil ity for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per directi ons of the Engineer-in-Charge : 5550 PJEWAT1701: 15 mm nominal outer dia pipes 5560 PJEWAT1702: 20 mm nominal outer dia pipes 5570 PJEWAT1703: 25 mm nominal outer dia pipes 5580 PJEWAT1704: 32 mm nominal outer dia pipes 5590 PJEWAT1705: 40 mm nominal outer dia pipes 5600 PJEWAT1706: 50 mm nominal outer dia pipes 5610 PJEWAT1707: Internal Work - Concealed in wall: Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stab ility for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spa cing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good th e same including testing of joints complete as per directions of the Engineer-in-Charge : 5620 PJEWAT1708: 15 mm nominal dia pipes 5630 PJEWAT1709: 20 mm nominal dia pipes 5640 PJEWAT1710: 25 mm nominal dia pipes 5650 PJEWAT1711: 32 mm nominal dia pipes 5660 PJEWAT1712: External Work: Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solve nt cement, trenching, refilling & testing of joints complete as per directions of the Engineer-in-Charge : 5670 PJEWAT1713: 15 mm nominal dia pipes 5680 PJEWAT1714: 20 mm nominal dia pipes 5690 PJEWAT1715: 25 mm nominal dia pipes 5700 PJEWAT1716: 32 mm nominal dia pipes 5710 PJEWAT1717: 40 mm nominal dia pipes 5720 PJEWAT1718: 50 mm nominal dia pipes 5730 PJEWAT1719: 65 mm nominal dia pipes 5740 PJEWAT1720: 80 mm nominal dia pipes 5750 PJEWAT1721: 100 mm nominal dia pipes 5760 PJEWAT1722: 150 mm nominal dia pipes 5770 PJEWAT1723: G.I. PIPES : 5780 PJEWAT1724: Internal Work - Exposed on Wall: Providing and fixing G.I. pipes complete with G.I. fittings and clamps, including cutti ng and making good the walls etc. : 5790 PJEWAT1725: 15 mm dia nominal bore 5800 PJEWAT1726: 20 mm dia nominal bore 5810 PJEWAT1727: 25 mm dia nominal bore 5820 PJEWAT1728: 32 mm dia nominal bore 5830 PJEWAT1729: 40 mm dia nominal bore 5840 PJEWAT1730: 50 mm dia nominal bore 5850 PJEWAT1731: Internal Work - Concealed in wall: Providing and fixing G.I. Pipes complete with G.I. fittings and clamps, including mak ing good the walls etc. concealed pipe, including painting with anti-corrosive bitumastic paint, cutting chases and making good the wall : 5860 PJEWAT1732: 15 mm dia nominal bore 5870 PJEWAT1733: 20 mm dia nominal bore 5880 PJEWAT1734: External Work: Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. : 5890 PJEWAT1735: 15 mm dia nominal bore 5900 PJEWAT1736: 20 mm dia nominal bore 5910 PJEWAT1737: 25 mm dia nominal bore 5920 PJEWAT1738: 32 mm dia nominal bore 5930 PJEWAT1739: 40 mm dia nominal bore 5940 PJEWAT1740: 50 mm dia nominal bore 5950 PJEWAT1741: 65 mm dia nominal bore 5960 PJEWAT1742: 80 mm dia nominal bore 5970 PJEWAT1743: Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including c utting and threading the pipe etc. complete : 5980 PJEWAT1744: 25 to 40 mm nominal bore 5990 PJEWAT1745: 50 to 80 mm nominal bore 6000 PJEWAT1746: Fixing water meter and stop cock in G.I. pipe line including cutting and threading the pipe and making long screws etc. complete. [Note: Cost of water meter and stop cock to be paid separately]. 6010 PJEWAT1799: BRASS FITTINGS : 6020 PJEWAT1800: Providing and fixing brass bib cock of approved quality : 6030 PJEWAT1801: 15 mm nominal bore 6040 PJEWAT1802: 20 mm nominal bore 6050 PJEWAT1803: Providing and fixing brass stop cock of approved quality : 6060 PJEWAT1804: 15 mm nominal bore 6070 PJEWAT1805: 20 mm nominal bore 6080 PJEWAT1806: Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 6090 PJEWAT1807: 20 mm nominal bore 6100 PJEWAT1808: 25 mm nominal bore 6110 PJEWAT1809: 32 mm nominal bore 6120 PJEWAT1810: 40 mm nominal bore 6130 PJEWAT1811: 50 mm nominal bore 6140 PJEWAT1812: 65 mm nominal bore 6150 PJEWAT1813: 80 mm nominal bore 6160 PJEWAT1971: C.P. BRASS FITTINGS : 6170 PJEWAT1972: Providing and fixing C.P. brass bib cock of approved quality conforming to IS-8931 : 15 mm nominal bore 6180 PJEWAT1973: Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms : 15 mm nominal bore 6190 PJEWAT1974: Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms : 15 mm nominal bore 6200 PJEWAT1975: Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS-8931 : 15 mm nominal bore 6210 PJEWAT1976: Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS-8931 : 15 mm nominal bore 6220 PJEWAT1977: Providing and fixing C.P. Brass extension nipple (size 15mm x 50mm) of approved make and quality as per directions of th e Engineer-in-Charge. 6230 PJEWAT1978: Providing and fixing following C.P. Brass central hole wash basin mixer with copper pipe/ pipes and brass nuts of size 1 5mm, etc. complete including cutting & making good the walls wherever required complete in all respects as per specifications and di rections of the Engineer-in-Charge : 6240 PJEWAT1979: C.P. central hole wash basin mixer (Ref. Make: JAQUAR, Model: Cat. No.-7171 Queens or approved equivalent) with 2 nos. x 10mm diameter & 450mm long copper pipes. 6250 PJEWAT1980: C.P. central hole wash basin mixer (Ref. Make: JAQUAR, Model: Cat. No.-167 or approved equivalent) with 1 no. x 10mm dia meter & 450mm long copper pipe. 6260 PJEWAT2382: Disinfecting C.I. water mains by flushing with water containing bleaching powder @ 0.5 gms per litre of water and cleani ng the same with fresh water, operation to be repeated three times including getting the sample of water from the disinfected main t ested in the municipal laboratory : 6270 PJEWAT2383: 80 mm diameter C.I. pipe. [Note: Unit M shall mean PER 100 METRE] 6280 PJEWAT2384: 100 mm diameter C.I. pipe. [Note: Unit M shall mean PER 100 METRE] 6290 PJEWAT2385: 125 mm diameter C.I. pipe. [Note: Unit M shall mean PER 100 METRE] 6300 PJEWAT2434: Cleaning of terrace/ loft water storage tank (inside surface area) up to 2000 litre capacity at all heights with coconut brushes, duster etc., removal of silt, rubbish from the tank and cleaning the tank with fresh water disinfecting with bleaching pow der @ 0.5gm per litre capacity of tank, including marking the date of cleaning on the side of tank body with the help of stencil and paint and disposing of malba, all complete as per the directions of Engineer-in-Charge. [Note: The old date already written on tank should be removed with paint remover or black paint and if date is not written with the stencil or old date is not removed deductio n will be made @ Rs. 0.10 per litre if during cleaning any G.I. fittings or ball cock is damaged that is to be repaired by the Contr actor at his own cost and nothing extra will be paid on this account]. 6310 PJEWAT2435: Cleaning of underground sump, Over Head R.C.C. Tank (independent staging) including disposal of slit and rubbish, all as per direction of Engineer-in-Charge. The cleaning shall consist following operations: (1) Tank shall be emptied of water by pumping & bottom shall be cleaned of slit and other deposits. (2) Entire surface area of the sump shall then scrubbed thoroughly with wir e brush etc. and pressure washed with water. (3) Chlorination of RCC internal surface by liquid chlorine. (4) The treated surface sh all be dried using air jetting and all loose particles shall be removal from the surface. (5) Finally the surface shall be treated w ith ultra-violet radiation etc. as per direction of the Engineer-in-Charge. 6320 PJEWAT2436: Disconnecting damaged overhead/ terrace PVC water storage tank of any size from water supply line and removing from th e terrace including shifting at ground level as per the directions of Engineer-in-Charge. 6330 PJEWOO0237: Providing and fixing panelled or panelled & glazed shutters 35 mm thick for doors, windows and clerestory windows fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per directions of the Engineer-in-Charge. [Note: Butt hinges and necessary screws shall be paid separately under relevant item of SOR] : 6340 PJEWOO0238: Second class teak wood 6350 PJEWOO0239: Kiln seasoned and chemically treated hollock wood 6360 PJEWOO0240: Kiln seasoned selected planks of sheesham wood 6370 PJEWOO0241: Providing and fixing panelled or panelled & glazed shutters 30 mm thick for doors, windows and clerestory windows fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per directions of the Engineer-in-Charge. [Note: Butt hinges and necessary screws shall be paid separately under relevant item of SOR] : 6380 PJEWOO0242: Second class teak wood 6390 PJEWOO0243: Kiln seasoned and chemically treated hollock wood 6400 PJEWOO0244: Kiln seasoned selected planks of sheesham wood 6410 PJEWOO0245: Providing and fixing 35 mm thick factory made laminated veneer lumber door shutter conforming to IS:14616 and TADS 15:20 01 (Part B), fixing with butt hinges of required size with necessary screws, all complete as per directions of the Engineer-in-Charg e and panelling with panels of: [Note: Butt hinges and necessary screws shall be paid separately] : 6420 PJEWOO0246: 12 mm thick plain grade-1, medium density flat pressed three layer particle board FPT-I or graded wood particle board FP T-I, IS:3087 marked, bonded with BWP type synthetic resin adhesive as per IS:848 : 6430 PJEWOO0247: 12 mm thick pre-laminated particle board (decorative lamination on both sides) grade -1, medium density flat pressed, th ree layer particle board FPT-I or graded wood particle board FPT-I, conforming to IS:3087, bonded with BWP type synthetic resin adhe sive as per IS : 848 and pre-laminated conforming to IS:12823, Grade 1, Type-II marked. 6440 PJEWOO0248: 12 mm thick one side Pre-laminated particle board (decorative lamination on one side and other sides balancing laminatio n) grade-1, medium density flat pressed, three layer particle board FPT-I or graded wood particle board FPT-1 conforming to IS:3087 bonded with BWP type synthetic resin adhesive as per IS:848 and pre-laminated conforming to IS:12823, Grade-1, Type-II marked. 6450 PJEWOO0249: Providing and fixing panelling or panelling & glazing for panelled or panelled & glazed shutters (25 mm to 40 mm thick s hutters) for doors, windows and clerestory windows [Note: Area of opening for Panel inserts/ Glass panes excluding portion inside gr ooves or rebates shall be measured for payment] : 6460 PJEWOO0250: Second class teak wood 6470 PJEWOO0251: Kiln seasoned and chemically treated hollock wood 6480 PJEWOO0252: Float Glass Panes - 4.0 mm thick (weight not less than 10 Kg/SQM) 6490 PJEWOO0253: Float Glass Panes - 5.5 mm thick (weigth not less than 12.5 Kg/SQM) 6500 PJEWOO0254: Fly proof Stainless Steel (Grade 304) wire gauge with 0.5 mm dia. wire and 1.4 mm wide aperture with matching wood beadi ng 6510 PJEWOO0255: 12 mm thick Exterior Grade-I MDF Board conforming to IS:14587, pre-laminated with decorative lamination on both side 6520 PJEWOO0256: 12 mm thick Marine plywood conforming to IS:710 6530 PJEWOO0257: 12 mm thick Fire retardant plywood conforming to IS:5509 6540 PJEWOO0258: Providing and fixing 35mm thick glazed shutters for doors, windows and clerestory windows using 4.0 mm thick float glass panes, including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws : 6550 PJEWOO0259: Second class teak wood 6560 PJEWOO0260: Kiln seasoned and chemically treated hollock wood 6570 PJEWOO0261: Kiln seasoned selected planks of sheesham wood : 6580 PJEWOO0291: Providing and fixing ISI marked flush door shutters conforming to IS:2202 (Part I) non-decorative type, core of block bo ard construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands a nd face veneers on both faces of shutters : 6590 PJEWOO0292: 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws 6600 PJEWOO0293: 30 mm thick including ISI marked Stainless Steel butt hinges with necessary screws 6610 PJEWOO0294: 25 mm thick (for cupboard) including ISI marked nickel plated bright finished M.S. piano hinges with necessary screws 6620 PJEWOO0295: Extra for providing and fixing flush doors with decorative veneering instead of non decorative ISI marked flush door shu tters conforming to IS:2202 (Part-I) : On one side only 6630 PJEWOO0296: Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (ov er all area of door shutter to be measured). 6640 PJEWOO0297: Extra for providing vision panel not exceeding 0.1 sqm in all type of flush doors. [Notes: (1) Cost of glass excluded. ( 2) Overall area of door shutter to be measured] : 6650 PJEWOO0298: Rectangular or square 6660 PJEWOO0299: Circular 6670 PJEWOO0300: Extra for cutting rebate in flush door shutters. [Note: Total area of the shutter to be measured]. 6680 PJEWOO0301: Providing and fixing wire gauge shutters using stainless steel grade 304 wire gauge with wire of dia 0.5 mm and average width of aperture 1.4 mm in both directions for doors, windows and clerestory windows with necessary screws : 6690 PJEWOO0302: 35 mm thick shutters with ISI marked M.S. pressed butt hinges bright finished of required size : 6700 PJEWOO0303: Second class teak wood 6710 PJEWOO0304: Kiln seasoned and chemically treated hollock wood 6720 PJEWOO0305: Kiln seasoned selected class of sheesham wood 6730 PJEWOO0328: Providing and fixing chromium plated brass curtain rods having wall thickness of 1.25 mm with two chromium plated brass brackets fixed with C.P. brass screws and PVC sleeves etc., wherever necessary complete : 6740 PJEWOO0329: 12 mm dia. 6750 PJEWOO0330: 20 mm dia. 6760 PJEWOO0331: 25 mm dia. 6770 PJEWPF2691: WATERPROOFING : 6780 PJEWPF2692: Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen and the like consisting of : (a) First course of applying cement slurry @ 4.4 Kg/sqm mixed with water proofing compound conforming to IS:2645 in recommended proportions including rounding off junction of vertical and horizontal surface. (b) Second course of 20 m m cement plaster 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface. (c) Third course of applying blown or residual bitumen applied hot at 1.7 Kg/ sqm of ar ea. (d) Fourth course of 400 micron thick PVC sheet. [Note: Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 Kg/sqm]. 6790 PJEWPF2698: Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing ceme nt compound consisting of applying : (a) After surface preparation, first layer of slurry of cement @ 0.488 Kg/sqm mixed with water proofing cement compound @ 0.253 Kg/sqm. (b) Laying second layer of fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm. (c) Third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 K g/sqm mixed with water proofing cement compound @ 0.670 Kg/sqm and coarse sand @ 1.289 Kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around. (d) Fourth and final layer of brick tiling with cement mortar (which will be paid for separately). For the pu rpose of measurement the entire treated surface will be measured. 6800 PJEWPF2699: Grading roof for water proofing treatment with : 6810 PJEWPF2700: Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) 6820 PJEWPF2701: Cement mortar 1:3 (1 cement : 3 coarse sand) 6830 PJEWPF2702: Cement mortar 1:4 (1 cement : 4 coarse sand) 6840 PJEWPF2703: Providing and applying fibre reinforced elastomeric liquid water proofing membrane with resilient acrylic polymers havin g Sun Reflectivity Index (SRI) of 105 on top of concrete roof in three coats @ 10.76 litre/10 sqm. One coat of self-priming of elast omeric waterproofing liquid (dilution with water in the ratio of 3:1) and two coats of undiluted elastomeric waterproofing liquid ( dry film thickness of complete application/ system not less than 500 microns). The operation shall be carried out after scrapping an d properly cleaning the surface to remove loose particles with wire brushes, complete in all respect as per directions of the Engine er-in-Charge. 6850 PJEWPF2704: Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC struc tures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels/ su bway and bridge deck etc., prepared by mixing in the ratio of 5:2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3:1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative ( internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrost atic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and directions of the Engineer-in-Charge. The product performance shall carry guaranteed for 10 years against any leakage : 6860 PJEWPF2705: For vertical surface two coats @ 0.70 kg per sqm per coat 6870 PJEWPF2706: For horizontal surface one coat @ 1.10 kg per sqm 6880 PJEWPF2707: Providing and applying polymer modified, flexible cementatious negative side waterproofing coating with elastic waterpro ofing polymers on interior wall plaster surface in three coats @ 14.35 Kg/10 sqm. One coat of self priming of cementatious waterproo fing polymer (dilution with water in the ratio of 1:1) and two coats of cementatious waterproofing polymer (dilution with water in t he ratio of 3:1 ) after scrapping and properly cleaning the surface to remove pre-existing paint film & loose particles till plaster is visible, complete in all respect as per 10 NRECIV0002: Through cleaning of paved and unpaved areas, roads, road side berms, broming removal of scraps and other unwanted left o ver materials including removal of chockage in the drains, removal of chockage from the road side / pave or unpaved area side drains and disposal of the rubbish etc. to the nearest garbage bin or as directly by Engineer-in-charge including laboures, broom, trolley and other consumables etc.complete. 20 NRECIV0003Cleaning the tiles, lavatory, flooring, urinals etc. by removing stains etc. by using Vim powder / cleaning powder / ISI g rade black phenyle / while phenyle / Acid /Naptha balls / Coir brushes / wire brushes Finit in required proportion to make the are a clean and free from all dust, dirt and stains etc. including cost of all labour and materials complete. (Only floor area shall be measured). 30 NRECIV0004Mopping of floors of offices, toilets, control rooms, electrical sub station etc. with soap solution or phenyle water with wet cloth after sweeping the floor with phooll broom, removing cob-webs with all tools, tackles, labour & materials etc. complete a s per directions of Engineer -in-charge including cleaning of ventilator glass panes from both the sides upto any height with cleani ng powder,paint remover as per requirement all labour, material etc.complete. 40 NRECIV0005Carrying out miscellaneous activities related to general maintenance like daily dusting the furnitures, walls shelves, cle aning the carpets, sofas, Cleaning and sweeping the stair case, passages, backyard, verandah, garrages, removal of cow webs, with al l labours, tools & tackles complete including supervising charges. (Unit EA shall mean carrying out above activities for 8 hrs. a day). 50 NRECIV0008Collection of Kitchen waste, dry waste & toxic waste in offices and colony from all Residential & Public Buildings, Execut ive Hostel, Staff Hostel, Canteen, Guest House, Club etc. The workmen shall collect the waste from each house & Public Buildings, se gregate the waste into biodegradable & non bio-degradeable waste and finally dispose them separately at designated place (Dumping Ya rd/ Pit) on daily basis as per requirement, with trained workmen, with all labour, tools, tackles, safety & protective clothes etc. complete as per direction of Engineer-in-charge. All consumables required including manpower, tools & tackles, PPEs, uniform to work men, etc. are to be supplied by Contractor without any extra cost and performing work as per item decription and direction of Engine er-in-Charge as well as instructions in Special Condition of Contract if any. Payment of Paddle Rickshaw (thela) will be made sepera tely. The unit MONTH (MON) shall mean per house/building per month 60 PJEDRA2588Pumping out water caused by springs, tidal or river seepage, broken water mains or drains and the like. [Note: Unit KL s hall mean KILO LITRE] 70 PJEHOR2828Supplying and stacking of good earth at site including royalty and carriage up to any lead complete. [Note: Volume of eart h measured in stacks will be reduced by 20% for payment]. 80 PJEHOR2830Supplying and stacking of well decayed cattle manure at site including royalty and carriage up to any lead complete. [Note : Volume of cattle manure measured in stacks will reduced by 8% for payment]. 90 PJEHOR2835Mixing earth and sludge or manure in the required proportion specified or directed by the Engineer-In-Charge. 100 PJEHOR2836Spreading of sludge, dump manure and/or good earth in required thickness including removal of debris/ un-wanted material, consolidation, dressing, levelling and watering etc. complete as per directions of the Engineer-in-Charge. [Note: Cost of sludge, du mp manure and/or good earth shall be paid separately under relevant item of SOR]. 110 PJEHOR2861Supply and planting sapling (not less than 45 cm in height and 60 cm centre to centre) of Casurina, Labrum, Gulmohar, Asho kas, Bottle Palm, Bougenvilla, Hibiscus, Roses or other approved type of variety of plants, watering & maintenance for 30 days minim um complete in all respects inclusive of cost of all materials, labour, tools, tackles etc. as per specifications and directions of the Engineer-in-Charge. 120 PJEHOR2898Cutting of hedge/ edge including removing of cut material, cleaning, hoeing of hedge/ edge, bed watering, manuring and app lying insecticides and fungicides etc. (excluding the cost of all materials) complete as per directions of the Engineer-in-Charge. [ Note: Unit SQM shall mean PER SQM PER MONTH.] 130 PJEHOR2903Pruning, trimming, shaping of trees/ shrubs (height 15 feet & above) and removal of cut materials up to 50m lead inclusive of all labour, T&P, materials etc. complete as per direction of the Engineer-in-Charge. [Note: Unit EA shall mean PER TREE]. 140 PJEHOR2904Providing and watering of Horticulture features i.e. lawn, tree, shrubs, hedge/ edge, ground cover etc. with irrigation wa ter at the site of work. Watering shall be done through water tanker having 5000 litre capacity with one labour for watering includi ng cost of water, filling of tanker, watering at site with all leads and lifts as per direction of the Engineer-in-Charge. [Note: Un it EA shall mean PER TRIP]. 150 PJEHOR2908Cleaning and Sweeping of Lawn/ Garden area and keep it neat & clean by mechanized method/ manually, removimg litter, debri s, picking of leaves, papers, plastic bottles etc. including disposal of collected waste in dustbin/ designated place, as per direct ion of the Engineer-in-Charge. [Note: All T&P, materials/ articles shall be provided by the Contractor]. 160 PJEHOR2909Removal of garden waste by TATA 407 or equivalent capacity vehicle including loading/ unloading, carriage up to 1.0 Km lea d & disposal at designated place etc. complete as per direction of the Engineer-in-Charge. [Note: Unit EA shall mean PER TRIP]. 170 PJEWAT2434Cleaning of terrace/ loft water storage tank (inside surface area) up to 2000 litre capacity at all heights with coconut b rushes, duster etc., removal of silt, rubbish from the tank and cleaning the tank with fresh water disinfecting with bleaching powde r @ 0.5gm per litre capaci ty of tank, including marking the date of cleaning on the side of tank body with the help of stencil and p aint and disposing of malba, all complete as per the directions of Engineer-in-Charge. [Note: The old date already written on tank s hould be removed with paint remover or black paint and if date is not written with the stencil or old date is not removed deduction will be made @ Rs. 0.10 per litre if during cleaning any G.I. fittings or ball cock is damaged that is to be repaired by the Contrac tor at his own cost and nothing extra will be paid on this account].
Contract Date: Dec 16, 2025 Contract Value : 38.05 Lakh
Boards / Undertakings / PSU No of Bidders 10
25.
Housing Urban and Rular Development #8419105 AOC
Tender For Dhule Industrial Area Interior Work Of Newly Constructed Office Building With Internal Electrification. - Providing and fixing in position Gypsum board false ceiling with 12.5mm thick Gypsum boards,screwed/fixed to the under structure of suspended G.I. Grid constructed and suspended from the main ceiling consisting of ceiling sections of size 25 x 50 mm maximum center to center distance of 600 milimetre perimeter channel and intermediate channels at maximum center to center distance 1200 milimetre galvanized grid should be fixed to reinforced cement concrete slab. The gypsum board should be fixed to galvanized iron grid with necessary screws. The boards should be taped and filled from underside to give smooth, seamless ceiling. The rate should include necessary additional ceiling sections and intermediate channels. Additional intermediate channels should be fixed to strap hangers for additional support to prevent strapping at every 1200 milimetre item to be completed in all respect including necessary sleeves for ducts finishing of joints cut outs, painting including labour, material, lifts etc. all complete. 2 Providing and Fixing Soft Fibre Acoustical Suspended Ceiling System with Optra (Bevelled Tegular) Edge Tiles of size 15mm Exposed Grid. The tiles should have Humidity Resistance (RH) of 95%, NRC 0.9 - 1.0, Light Reflectance ?85%, Colour White, Fire Performance UK Class 0 / Class 1 (BS 476 pt - 6 &7) in module size of 600 x 600 x 15mm , suitable for Green Building application, with Recycled content of 66% GW and 74% RW. The tile shall be laid on precoated G.I channel 32 with 15 mm wide T - section flanges colour white having rotary stitching on all T sections i.e. the Main Runner, 1200 mm and 600 mm Cross Tees with a web height of 32 mm and a load carrying capacity of 7 Kilograms/M2 with a minimum pull out strength of 100 Kilograms. The T Sections have a Galvanizing of 90 grams per M2 and need to be installed with Suspension system The Tile and Grid system used together should carry a 10 year warranty. products approved as per GRIHA and BS 476 etc. complete. 3 Providing and supplying Armstrong ‘Optra Acoustical Wall Panelling’ with square edges made of fibre glass substrate 25mm thick and wrapped on the front side with an acoustically transparent and fire-resistant fabric with an option of colours as per the choice of the Architect/ Person in-charge of size 2100x600 or 600x600 mm providing a minimum sound absorption level of 0.90 NRC to be affixed to wall using Wall panel impalers supplied by M/s Armstrong Industries India Pvt. Ltd and construction adhesives as per the instructions laid down by the manufacturer. (Rates excluding GST) 4 Providing and fixing Wooden rafter or ceiling at all height including providing and fixing of aluminium frame work and rafter made up of ply using 9/12/19 mm with complete hardware fitting etc complete as per direction of Engineer - in - charge (Laminate Finish) (Rates excluding GST) 5 Providing and fixing Carpet Tile of CCIL make, shade and pattern and of the following specification: Loop pile carpet tile,of size 500 mm x 500 mm with Tufted… (Rates excluding GST) 6 Providing and Fixing in position Aluminium Frame work for Partitions, paneling, boxing, soffits with vertical members at not more than 600 mm centers & horizontal members not more than 600 mm centers.with L patti joint , Complete including necessary aditional supports, bracing runner etc. complete. Item to be completed in all respects as per drawings & instructions from Engineer - In - Charge. (Rates excluding GST) Size 50 X 50 X 1.62 mm 7 Size 50 X 25 X 1.62 mm 8 Providing & Fixing in position on existing frame work including all materials, labour etc complete. Item to be completed in all respects as per drawings & instructions from Engineer - In - Charge. (Rates excluding GST) 6 mm thk Marine plywood 9 9 mm thk Marine plywood 10 12 mm thk Marine plywood 11 19 mm thk Marine plywood 12 9 mm thk Decorative MDF panelling 13 Providing and fixing 3mm - 4mm thick group matching Decorative Veneer of approved quality and make, of required size and width as per site condition including surface preparation pasting with approved adhesive and finishing it evenly to get flat surface. The cost of openings for switches, AC Facia, any other cutout etc. shall be included in the rates quoted. complete as per detail drawing & directions by Architect. No extra payment will be made towards providing any pattern .The item includes finishing the surface with 3 or more coats of melamine polish as per the direction by Architect. (Rates excluding GST) 14 Providing and fixing 1.5 MM thick group matching Laminate of approved quality and make, of required size and width as per site condition including surface preparation pasting with approved adhesive and finishing it evenly to get flat surface. The cost of openings for switches, AC Facia, any other cutout etc. shall be included in the rates quoted. complete as per detail drawing & directions by Architect. No extra payment will be made towards providing any pattern .(Basic Rate for laminate: Rs.55 per sft.) (Rates excluding GST) 15 Providing & fixing Trap Doors made out of required framework, 19mm thk plywood finished with material 1.5 mm thk laminate from outside and 1mm thk laminate from inside. Site modification as per requirement has to be undertaken without any extra cost. (Rates excluding GST) 16 35mm thk Flush Door both side Laminate - Providing & fixing 35mm thk. Phenol bonded Flush door or Partly Glazed finish with 1.5mm thk. Laminate on both sides as per approved pattern. All edges should finish with teak wood lipping with melamine polish. All complete as per instructions & approval of EIC. Note: The rate of all doors shall include all hardware such as door handles, hinges, door closures/floor spring, dead lock, PVC door buffer, door stopper, latches etc. as required. (Rates excluding GST) 17 Storages Providing & fixing in position 460 mm deep storage / Wardrobe unit along with partitions etc with 1) sides, top, bottom shelves made out of 19mm marine plywood for all inside surfaces 2)6 mm thk. marine ply backing panels 3) Shutters made out of 19 mm thick block board finish with material & 6mm thk teakwood leaping with egde moulding of approved profile if any shall be provided in all exposed ply edge surfaces& be finished with melamine polish.4) Finish 1mm thk laminate inside & 1.5mm thk laminate out side, hardwares such as heavy duty hinges, brass body locks (Ebco make) with extra large group key of approved quality, magnetic ball catchers, handles, towerbolt etc. All exposed woodwork to be finished with 3 coats of melamine polish & all internal surface finished with 1 mm thk laminate. The exposed surfaces shall be finished with 1.5 mm thk. laminate of approved shade & colour. All as per detailed drgs and instructions of EIC / Architect (Rates excluding GST) 18 Assistant Table (size 1500 x Number 900 x 750 mm) side table (size 1100 x 450 x 700 mm) in Laminate... Providing & arranging in position desk units in 19mm thk. Marine plywood including side unit, drawer unit, tea tray, pencil tray, pullout tray, footrest. All drawers to be in plywood with 19 mm in front & 12mm thk in rear & sides & bottom in 6 mm thk. Plywood Internal surfaces to be Laminate. Table tops, drawer unit fronts & sides to be finished as per drawings. The front modesty panel etc shall be finished as per drawings & instructions of the EIC / Consultant all complete. All trays in writing desks, side units to have concealed stoppers. All pencil trays shall have small compartments for keeping miscellaneous stationaries. All beadings, mouldings & exposed woodwork to be in teak wood. Foot rest shall be made out of 19 mm plywood frame work with 6 mm top & shall be finished with matching Laminate. (Rates excluding GST 19 Reception Table (2000 X 600 X Number 975)... Providing and fixing in position Reception Table of approved shape made out of 19 mm thick marine grade plywood fixed on intermediate 19mm thick marine grade plywood verticals at certain interval (as shown in the drawings) with necessary wooden members & S.S.studs with glass top finished with approved Laminate finish on all exposed surfaces. .Also including cost of all necessary wooden beading / mouldings finished with melamine polish. Rate should be including cost of hardware of approved make. complete as per detail drawing, as specified and as directed by Architect. For Reception Counter - Two pedestal with 4 nos of drawer & one keyboard tray is required. (Rates excluding GST) 20 Conference Table (size 8600 x 2000 x 750 mm)... Providing & fixing in position Meeting Room Table of approved shape shown in drawing. Table top made out of 19*19mm & 50*38mm TW frame work with both side 6mm thk marine plywood in two layers finished with approved veneer. Apron made out of 50*50 mm TW frame work with both side 9 mm thk marine plywood finished with approved veneer. Edge of Table finished with 50*50 mm TW moulding with melamine polish. Footrest & skirting made out of 19 mm thk marine plywood finished with approved veneer. Edge of footrest finished with 25 mm thk wooden half round moulding with melamine polish. 50*50 mm wooden connecting members. (Size as per enclosed drawing) Rate including cost of wooden beadings, mouldings, inlays, etc. Top should be finished with approved veneer. Sides finished with approved veneer & melamine polish complete as per detail drawing, as specified & as directed by Architect. (Rates excluding GST) 21 Dining Table Size 900 x 900 x 750 mm ht... Providing & arranging in position Dining tables made out of Laminate top and stand with proper joinery & hardware as per drawing. the top finished with bevelled edges. Item to be completed in all respect as per drawing & instructions from Engineer-incharge (Rates excluding GST) 22 CENTER-TABLE... CENTER -TABLE - Providing & arranging in position centre tables made out of TW members 40X 75 mm with proper joinert & hardware as per drawing. The top finished with 12mm thk tinted glass with bevelled edges. Item to be completed in all respect as per drawing & instruction from E.I.C. of given size & shape (Rates excluding GST) 23 CORNER-TABLE... Square/circular corner Table - Providing & arranging in position centre tables made out of TW members 40X 75 mm with proper joint & hardware as per drawing. The top finished with 12mm thk tinted glass with bevelled edges. Item tobe completed in all respect as per drawing & instruction from E.I.C. of given size & shape (Rates excluding GST) 24 Modular workstations consist of low ht. partition screen, work tops, Pedastal unit ,filing stoarges( only in few cases), key board tray & CPU trolley as specification mentioned below.The profiles of the Aluminium partition frame should be as per the attached sheet and the as per the weight per Rmt mentioned on the sheet.. Work top - 25 mm hk. Pre laminated particle board cut to size & shape as per design & drawings. Edges to be fixed with 2mm thk PVC edge binding of approved make & matching to laminate. Key board tray & CPU Trolley - Each work station shall have PVC moulded key board tray & M. S. powder coated CPU Trolley with castors. Pedastal unit - 3 drawer pedastal unit of overall size 450 deep X 450 wide X 725 ht made out of 18 / 16 mm prelaminated board for caracus & 12 mm prelaminated board for drawers. Top drawer to be on roller slides and two lower drawers to be of 3 extension ball bearing slides. Partition screen: 60mm thick to have one cable channel along main spine, MFC (Melamine Finish Chipboard) on both side upto table top ,each workstation with one tackable board and white board. Screen in front of the table to have frosted glass panel above table top. (Rates excluding GST) 25 EXECUTIVE cabin table (size 2750 x 1200 x 750 mm) side table (size 1500 x 600 x 700 mm) in Veener.. Providing & arranging in position desk units in 19mm thk. Marine plywood including side unit, drawer unit, tea tray, pencil tray, pullout tray, footrest. All drawers to be in plywood with 19 mm in front & 12mm thk in rear & sides & bottom in 6 mm thk. Plywood Internal surfaces to be veneer with melamine polish. Table tops, drawer unit fronts & sides to be finished as per drawings. The front modesty panel etc shall be finished as per drawings & instructions of the EIC / Consultant all complete. All trays in writing desks, side units to have concealed stoppers. All pencil trays shall have small compartments for keeping miscellaneous stationaries. All beadings, mouldings & exposed woodwork to be in teak wood. Foot rest shall be made out of 19 mm plywood frame work with 6 mm top & shall be finished with matching veneer all molding shall be finish in 3 coats of melamine polish. All the tables shall have keyboard drawers to accommodate keyboards & mouse wherever necessary as per drawing. Rate include of all hardware, like hinges, drawer channel, handles, lock etc. drawings & also shall include CPU unit as shown in the drawings approved by Engineer-in-charge/Architect. No seperate payment shall be made for this. Tables all exposed surface finished with a approved veneer in approved pattern as per drawings. All exposed surface of side unit to be finished with an approved veneer. Providing & fixing in position side unit made out of 19 mm thk. Marine ply, with shelves, drawers, shutters etc. as per drawings, finished with approved veneer from outside & French polish from inside. Item to be completed in all respects as per drawing & instructions from EIC. The item shall include a set of drawer & openable shutters, as per the drawing & details. All shelves, openable shutters, drawer box, drawer front etc. shall be made out of 19 mm thick plywood. Drawer sides shall be in 12 mm thk Plywood. Drawer bottom shall be in 6 mm thk. Plywood. All exposed surfaces to be finished With veneer of approved shade & make. All complete 26 Staff Chair..Providing and placing in requireed position Godrej make Bravo Visitor Back 9U12RX 1 or equivalnet approved make the seat and back are made up of 1.2 cm. thick hot-pressed plywood, upholstered with fabric upholstery covers and moulded Polyurethane foam. The back foam is designed with contoured lumbar support for extra comfort. The seat has extra thick foam on front edge to give comfort to popliteal area. BACK SIZE: 47.5 cm. (W) x 58.0cm. (H) SEAT SIZE:47.0 cm. (W) x 48.0 cm. (D with the Polyurethane foam is moulded with density = 45 +/-2 kg/m3 and Hardness = 20 +/- 2 on Hampden machine at 25% compression. TWIN WHEEL CASTORS: The twin wheel castors are injection moulded in 30% Glass Filled black Nylon.complete as per manufacture specifications and as per instruction of Engineer in charge. (Rates excluding GST) 27 Providing and placing in requireed position Godrej make Kareena Visitor Back or equivalnet approved make the seat and back are made up of 1.2 cm. thick hot pressed plywood, upholstered with fabric upholstery covers and moulded Polyurethane foam. The back foam is designed with contoured lumbar support for extra comfort. The seat has extra thick foam on front edge to give comfort to popliteal area. BACK SIZE: 47.5 cm. (W) x 58.0cm. (H) SEAT SIZE:47.0 cm. (W) x 48.0 cm. (D with the Polyurethane foam is moulded with density = 45 +/-2 kg/m3 and Hardness = 20 +/- 2 on Hampden machine at 25% compression. TWIN WHEEL CASTORS: The twin wheel castors are injection moulded in 30% Glass Filled black Nylon. complete as per manufacture specifications and as per instruction of Engineer in charge (Rates excluding GST) 28 Providing and placing in requireed position Godrej or equivalent make Halo Mid Back Chair Model PCh- 9200R or approved equiivalant chair of size size 50.0cm W X 49.5cm (H) with 75.o cm (D) including necessary approved type and colour fabric complete as per manufacture specifications and as per instruction of Engineer in charge. (Rates excluding GST) 29 Providing & Arrangemnt of High Back, Synchronized Mechanism with Multiple Locking, Adjustable Armrest, Gaslift for Seat height adjustment, Standard 5-prong P/Nylon Base with Leatherite Upholstery 30 Providing & Arrangemnt of MId Back, Normal Syncro Mechanism , Fixed Armrest , Gaslift for Seat height adjustment, Standard 5-prong/Nylon Base with Leather Upholstery 31 Providing & supplying multi seater sofas with teakwood internal frame out of size min. 70x40mm as mentioned in drawing with necessary spring/ rubberised coir/ 32 density polyurethene foam/100% latex rubber foam of appropriate quality & thickness as shown in the drawing with melamine polish on all exposed wooden surface. 75mm thk. for seat & 50mm thk for back. 25mm polyurethene in it to give required shape. The rate to include upholstry material of approved velvet (fabric) on outer side & on the inner side white cloth of approved qulaity shade etc. The contractor shall use appropriate size of frame work instead of mentioned to achieve desired shape & comfort as shown. All as per instructions of Engineer-incharge. (Rates excluding GST) a) Single Seater Sofa 32 b) Three Seater Sofa 33 c) Two Seater Sofa 34 palmet / Jamblining (upto 250mm wide).. Providing & fixing in position jamb lining of 19mm thk. plywood & finished as below with wooden moulding, exposed surfaces polished with 3 coats of melamine polish. All complete as per drawing & instructions of Engineer-incharge (Rates excluding GST) 35 Providing and fixing in position 12mm thick Soft Board paneling on partition surface including fabric cover, wood beading finished with melamine polish of approved shade etc. complete as per detail drawing, as specified and as directed by Architect/Enginner In Charge.. (Rates excluding GST) 36 Dust Bin (300mm Dia).. Providing & arranging in position dust bins out of perforated (min Size 350 mm dia x 400 mm Height). Item to completed in all respect as per drg & directions. (Rates excluding GST) 37 Roller Blinds..Providing and fixing Collinear Window Sahdings from Livin in 3/2 vane size having headrail and bottom rail made of aluminium alloy extruded profile, powder coated and provided in standard natural white color. The rolling tube should made up of aluminium alloy from extruded profile of Ø34 mm. The headrail dimensions should be in the range of: H 58mm x 72mm for the larger headrail. The cassette should conseal the working mechanisme rotary-- clutch that raises, lowers and tilts the shade contains and protects shading fabric when fully raised. All plastic parts are in white color. Operation options: endless cord loop. Installation to be done by quick release brackets (wall or ceiling). The fabric of this Silhouette Window Shadings should be anti static polyester vanes which have facings between 2 sheers layers (50mm wide) to reduce glare. Sheer layers made of white 100% knit polyester & the selection of colors, textures and opacities from the Livin collection as specified by the architect. The shading to be opearted by Esayrise mechanism with a continous cord loop operating option. The FABRIC shall be constructed from spun - bonded 100% polyester fibre, having Greenguard certified and recommended for sensitive areas like clean room condition and laboratories.all complete as per instructions of Engineer - in - charge. (Rates excluding GST) 38 Providing, fixing, applying by Company Trained Technicians, premium Wall Covering (Wall Fabric / Paper), as per details in attached specifications, or as per detailed specifications and colours attached, or approved equivalent, of approved colour, texture and design, including base and sub-base preparation (on top of existing P.O.P surface), all complete, in a neat and workman like manner, as per directions of Engineer-In-Charge. (Rates excluding GST) 39 Providing & fixing Artificate like Artifical Plant, Picture Artificial plants 40 Picture frame 41 providing and fixing approved Black Out Curtain to be fixed & commissioned as per manufacturers specification the work to be completed as per satisfaction and approved of EIC (Rates excluding GST) 42 Providing and applying plastic emulsion paint of approved quality, colour and shade to new surface in three coats including scaffolding, preparing the surface. (excluding primer coat) etc. complete. 43 Providing and fixing in position 12 mm thick Toughened Fully Clear Glass Door by using various glass patch fittings to be fixed with necessary fittings on the ceiling duly finished without giving any load on the false ceiling by using necessary hardware what ever necessary and required numbers to complete the job in all respect. Rate including cost of door with approval hardware such as patch fitting lock, handle, Floor Spring of approved make. Contractor is advised to submit working drawing with details patch fitting, sizes of glass panels etc and take approvals of consultants before execution of works. complete as per detail drawing, as specified and as directed by Architect. (Rates excluding GST) 44 Providing & fixing glazed partition made out of 8 mm thk clear glass with designs pattern as shown in drawing. Glass should fixed with required size of wooden beading which finished with 3 coats of melamine polish. Rate including cost of glass edge machine polishing in between 2 glass edges touching together (if required) complete all as per the drawing, details & specification & to the satisfaction of Engineer-in-charge. (Rates excluding GST) 45 Providing and applying plaster / wall punning with plaster of paris ( with plaster of paris material) in 10 to 13 millimeter thickness to previously plastered surface / or on newly brick surface ( Excluding rough cast plaster ) in all position including preparing and Finishing the surface scaffolding etc.complete. 46 Forssted 3m film.. Providing & fixing in position approved make colour & shade frost film on glass complete as per direction of manufacturer & instruction of Engineer - in - Charge. (Rates excluding GST) 47 Providing and fixing Indian teak wood joists and girders in timber floors of single, double or framed type including scaffolding if necessary, and one coat of primer etc. complete. 48 Providing and fixing shutter to wall cupboard made from 19 mm thick Teak particle board with approved coloured laminated face 1.5 mm thick bonded with phenol formaldehyde synthetic resin B.W.P. grade including lipping beading iron oxidised fixtures and fastening and oil primer coat etc. complete. (Excluding cupboard frame). 49 Concealing of Conduits (WG-MA/CC) Supplying & erecting HMS PVC conduit 20mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification no. WG-MA/CC. 50 Supplying & erecting HMS PVC conduit 25mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification no. WG-MA/CC. 51 Supplying & erecting HMS PVC conduit 32mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification no. WG-MA/CC. 52 Point Wiring (WG-PW) Point wiring for light/bell concealed type in min 20 mm HMS PVC conduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification no. WG-PW/CW 53 Point wiring for ceiling fan concealed type in min 20 mm HMS PVC conduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification no. WG-PW/CW 54 Point wiring for independent plug in minimum 20 mm HMS PVC conduit with 1.5 sq.mm (2+1E ) FRLSH grade copper wire, modular type switch, earthing and required accessories as per specification no. WG-PW/SW 55 Wiring for plug on board with switch socket surface/concealed type, copper wiring and earthing and with modular accessories as per specification no. WG-PW/CW 56 Modular switches and Accessories Supplying and erecting modular type switch 16/20 A with indicator on provided plate and box with wiring connections complete. 57 Supplying and erecting modular type 3 pin 6/16A multi socket with safety shutter on provided plate and box with wiring connections complete. 58 Supplying and erecting modular type T.V. socket single outlet on provided plate and box with wiring connections complete. 59 Supplying and erecting modular type telephone socket two gang with safety shutter on provided plate and box with wiring connections complete. 60 Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 1 module duly flushed to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. 61 Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 3 module duly flushed to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. 62 MAINS CIRCUIT WIRING- Providing and laying of following PVC Supplying and erecting PVC insulated PVC round sheathed FR 1 sq.mm (32 no. x 0.20mm dia.) 3 core flexible multi stranded copper industrial cable for voltage grade up to 1.1 kV 63 Supplying and erecting PVC insulated PVC round sheathed FR 1.5 sq.mm (30 no. x 0.25mm dia.) 3 core flexible multi stranded copper industrial cable for voltage grade up to 1.1 kV 64 Supplying and erecting PVC insulated PVC round sheathed FR 2.5 sq.mm (50 no. x 0.25mm dia.) 3 core flexible multi stranded copper industrial cable for voltage grade up to 1.1 kV 65 Supplying and erecting PVC insulated PVC round sheathed FR 4 sq.mm (56 no. x 0.30mm dia.) 3 core flexible multi stranded copper industrial cable for voltage grade up to 1.1 kV 66 Indoor LED Fittings (FG-IDF/LED) Supplying and erecting LED square / circular Max. 14 W down lighter / Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 1500 Lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs at L70B50 including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with minimum 2 years warranty as per specification No. FG-IDF/LED. 67 Supplying and erecting LED square / circular Max. 18 W down lighter / Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 2000 Lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs at L70B0 including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with minimum 2 years warranty as per specification No. FG-IDF/LED. 68 Supplying and erecting LED Panel Light (600mm X 600mm) Max. 30 W having CRCA powder coated housing, polystyrene diffuser having system lumens output of Min. 3600 Lumens, min. efficacy of 120 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs at L70B50 including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with minimum 2 years warranty as per specification No. FG-IDF/LED. 69 Supplying and erecting anodized aluminium light LED fitting (4 feet) Max. 22W with high transitivity diffuser with system lumens output of Min.2200 lumens , min. efficacy of 100 lumen/W, CRI>80, CCT upto 6000K, Beam Angle of 110 deg., Ripple<5%, THD<20%, p.f. >0.95, operating range of 200-270V, surge protection of 2 kV, Life class of 50,000 Hrs at L70B50 including driver with end caps on provided PVC Block/wooded board with minimum 2 years warranty as per specification No. FG-IDF/LED. 70 Decorative Outdoor Fittings (FG-ODF) Supplying and erecting Gate / garden light fitting with 300mm dia. glass bowl suitable for upto 12W LED Lamp on provided pipe as per specification No. FG-ODF/GLT. 71 Supplying & erecting integral post top lantern fixtures (light house type) suitable upto LED 18 W Lamp consisting of combination of spun aluminium canopy & clear acrylic top cover, cast aluminium pole cap on provided pole/ bracket as per specification no. FG-ODF/PTL. 72 Accessories for Indoor Fittings (FG-AS) Supplying and erecting luminous / modular type call bell indicator with plastic body, heavy duty coil and indicator lamp working on 230V A.C. supply with resetting arrangement complete erected on double wooden / sunmica board. 73 Supplying and erecting electronic type cordless call bell erected on T.W. board having portable bell push working on 9V D.C. battery and (effective range upto 45 meter) bell on 250 V A.C. supply. 74 Accessories for Outdoor Fittings (FG-BKT) Supplying and erecting Street light bracket made from 25 mm. dia ‘B’ class G.I. Pipe, 0.6 m in length along with pole cap of 300 mm length and 80 mm dia duly welded with provided leads as per specification no. FG-BKT/BPC. 75 Cable Tray (CB-CT) Providing & erecting hot dipped galvanised perforated type cable tray manufactured from 16 SWG GI sheet of 150 mm width & 75 mm height complete with necessary coupler plates & hardware. 76 Providing & erecting hot dipped galvanised perforated type cable tray manufactured from 16 SWG GI sheet of 300 mm width & 75 mm height complete with necessary coupler plates & hardware. 77 LT Cables (Copper) (CB-LT/CU) Supplying, erecting & terminating FR XLPE insulated, galvanised steel wire armoured (round) cable 1100 V, 3 core 2.5 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU 78 Supplying, erecting & terminating FR XLPE insulated, galvanised steel wire armoured (round) cable 1100 V, 4 core 4 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU 79 Supplying, erecting & terminating FR XLPE insulated, galvanised steel wire armoured (round) cable 1100 V, 4 core 6 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU 80 Energy Devices (APFC Panel) (CP-ED/APFC) Supplying, erecting, testing & commisioning 100 kVAr, 440 V, 3 phase, 50 Hz., APFC Panel with contactor logic with intelligent microprocessor relay, consisting of 2,3,5,10,20.20,20,20 or suitable steps of APP/MPP type capacitor units with detuned (harmonic filter) reactors of suitable rating, APFC panel shall be compliance to IEC 61439 and power quality IEC 61921 standard as per specification no. CP-ED/APFC. 81 LT - MCBs/ MCB Change Over Switch (SW-MCB) Supplying, erecting & marking SP MCB 6A to 32A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-MCB 82 Supplying, erecting & marking SP MCB 6A to 32A, B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-MCB 83 Supplying, erecting & marking DP MCB 6 A to 32 A, B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-MCB 84 Supplying, erecting & marking TP MCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-MCB 85 Supplying, erecting & marking FP MCB 6A to 32A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-MCB 86 Supplying, erecting and marking 4 pole isolator only switch version of miniature circuit breakers of 40A in provided distribution board. 87 LT - MCBDBs (SW-MCBDB) Supplying & erecting triple pole and neutral distribution board (TPNDB), SP/TP MCBs total 4 ways/12 Poles, with door, 1.2mm thickness surface/flush mounted, IP 43 Protection on provided iron/GI frame (vertical busbar type) as per specification no. SW-MCBDB. 88 Supplying & erecting triple pole and neutral distribution board (TPNDB), SP/TP MCBs total 8 ways/24 poles, with door, 1.2mm thickness surface/flush mounted, IP 43 Protection on provided iron/GI frame (vertical busbar type) as per specification no. SW-MCBDB. 89 Supplying & erecting triple pole and neutral distribution board (TPNDB), SP/TP MCBs total 12 ways/36 poles, with door, 1.2mm thickness surface/flush mounted, IP 43 Protection on provided iron/GI frame (vertical busbar type) as per specification no. SW-MCBDB 90 Supplying and erecting single pole and neutral distribution board (SPNDB), with 2 ways for incoming and 2 ways (2 poles) for outgoing SP MCBs, with door, 1.2mm thickness surface/flush mounted, IP 43 Protection on provided iron/GI frame as per specification no. SW-MCBDB 91 Supplying and erecting single pole and neutral distribution board (SPNDB), with 2 ways for incoming and 4 ways (4 poles) for outgoing SP MCBs, with door, 1.2mm thickness surface/flush mounted, IP 43 Protection on provided iron/GI frame as per specification no. SW-MCBDB 92 Supplying and erecting single pole and neutral distribution board (SPNDB), with 2 ways for incoming and 10 ways (10 poles) for outgoing SP MCBs, with door, 1.2mm thickness surface/flush mounted, IP 43 Protection provided on iron/GI frame as per specification no. SW-MCBDB 93 Fans (FG-FN) Providing and erecting air circulator 600 mm. sweep oscillating type, wall mounting 1440 RPM without speed regulator, overheat protection unit, totally enclosed, flame proof motor suitable for 230/250 volts single phase, 50 cycles A.C. supply, core lead wire and with moisture proof treatment to winding and with ‘E’ class insulation. 94 Supplying and erecting exhaust fan heavy duty 230 V, A.C. 50 cycles 375/380 mm. 900 RPM complete erected in position as per specification no. FG-FN/EXF 95 Supplying and erecting Energy Saving BLDC Ceiling fan 230 V A.C. 50 cycles 1200 mm, Max. Energy Consumption of 28W having service ratio (CMM/W) of Min. 8 , PF>0.9, THD<10% with IR remote control, Temperature Rise of Max. 40 deg.C, having external mounted control PCB completely erected in position as per specification no. FG-FN/CF 96 Air Conditioners (AP-AC) Supplying, installing, testing & commissioning split type variable speed inverter technology with minimum 3 to 1 convertible mode for compressor, room air conditioning unit 2.1TR to 2.3TR capacity having ISEER minimum 3.8 to maximum 4.39 suitable to operate on 250V, 50 Hz, A.C. supply having 1 no of air handling unit hi-wall/floor mounting type complete with refrigerant R32 having copper condenser, minimum 2.5PM filter, self diagnosis feature, stabilizer free operation & temperature display on indoor unit, noise level maximum 50dBA at position as per specification no. AP-AC/ SAC 97 Water Coolers & Refrigerators (AP-WC) Supplying, erecting, testing and commissioning self contained water cooler 230/250 V 50 cycles nominal cooling capacity of 80 litres per hour and storage capacity 120 litres with partially stainless steel body as per specification no. AP-WCR/WC 98 Water Purifiers (AP-WPF) 99 Supplying and erecting ultra violet storage type water purifier ( RO+UV+UF) with softener for safe drinking water consisting of UV germicidal tube of 8W capacity choke made of copper wire and two indicator lamps with output of purified water minimum 0.33 litre/min with activated carbon filter and softener operating on 230 V single phase A.C. supply with UV fail & filter change indication system .(for TDS more than 200) Rooftop ON grid solar systems (ESD-RT-ONG) 100 Supplying, installing, testing and commissioning of 25 kWp ON-GRID Solar pV System / Plant consisting Solar PV Poly Crystalline Panel (335 Wp X 75 Nos.) and Solar ON-GRID Inverter of similar capacity (THD<3%) with interconnecting wires / cables up to solar ON GRID inverter, proper base plate, canopy box to house Inverter and necessary accessories i.e. ACDB/ DCDB , MCB etc. wiring up to solar Inverter in casing and capping, display board, sign board, two distinct earthing, lightning arrester, liasoning charges, remote monitoring system with maintaining card / chip for 5 years including net charges for RMS System, complete upto net meter installation and export to the grid with 5 year ON-SITE warranty and 5 Years fully comprehensive maintenance contract as per Specification no. ESD-RT-ONG. 101 Concealing of Conduits (WG-MA/CC) Supplying & erecting HMS PVC conduit 25mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification no. WG-MA/CC. 102 Supplying & laying HMS PVC conduit 25mm dia with necessary accessories in RCC work/false ceiling/false flooring as per specification no. WG-MA/CC. 103 Telephone, Audio and Video Wiring (WG-TW/TW) 104 Supplying, erecting & terminating 2 pair telephone copper cable 0.5 mm dia. with high density polyethylene insulation, polyester taped, nylon rip cord & grey colour sheathed with FR PVC, confirming to ITD specification S/WS 113C laid in provided PVC casing-n-capping/conduit as per specification no. WG-TW 105 Supplying, erecting & terminating 20 pair telephone copper cable 0.5 mm dia. with high density polyethylene insulation, polyester taped, nylon rip cord & grey colour sheathed with FR PVC, confirming to ITD specification S/WS 113C laid in provided PVC casing-n-capping/conduit as per specification no. WG-TW 106 Telephone Accessories (WG-TW/TA) Supplying, erecting & commissioning MDF Box 50x50 pairs made from min. 1.5mm thick MS sheet as per specification no. WG-TA 107 Supplying, erecting & commissioning 50 pairs FR junction box with moulded plastic enclosure as per specification no. WG-TA 108 Supplying, installing, testing & commissioning digital (hybrid) type EPABX of 6 x 32 universal extensions suitable upto 96 extensions compliant to IEC 61000, EN 60950, CISPR 22, IS:9000 part 2/section 4 having LAN/WAN port, USB port, RS232 port as per specification complete as per specification no. WG-TA 109 Supplying, installing, testing & commissioning push button telephone instrument desk top/wall mount with caller ID & speaker unit as per specification complete. 110 Supplying, installing, testing & commissioning IP telephone instrument as per specification complete. 111 Modular switches and Accessories Supplying and erecting modular type telephone socket one gang with safety shutter on provided plate and box with wiring connections complete. 112 Supplying and erecting modular type telephone socket two gang with safety shutter on provided plate and box with wiring connections complete. Supplying and erecting modular type computer Jack RJ 45 with safety shutter, on provided plate and box with wiring connections complete. 113 Supplying and erecting modular type blanking plate two module, on provided plate & box. 114 Supplying and erecting PVC Surface modular switch box with double mounting plate for 2 module complete. 115 Cable Tray (CB-CT) 116 Providing & erecting hot dipped galvanised ladder type cable tray manufactured from 16 SWG GI sheet of 300 mm width & 100 mm height with required standard accessories. 117 ELV Cabling (WG-ELVC) Supplying and installing FR PVC sheathed HDPE insulated copper cat-6 cable with rodent proof and anti termite jacket suitable for networking compliant with ANSI/TIA-568.2-D standards in provided conduit/ casing-n capping as per specification no. WG-ELVC/NC 118 Supplying and installing FR PVC sheathed HDPE insulated copper cat-6 armoured cable suitable for networking compliant with ANSI/TIA-568.2-D standards as per specification no. WG-ELVC/NC 119 Supplying and erecting 24 fibers LSZH armoured multimode optical fiber cable with , core dia 50/125 µm (OM3), suitable upto 10 GBPS, compliant to IEC 60793/IEC 60794 standards, on wall/ ceiling or laid in provided pipe/trench as per specification no. WG-ELVC/OFC 120 Supplying and fixing 3 m 24 AWG multi stranded UTP patch cord with RJ-45 factory crimped connector of cat 6 type compliant ANSI/TIA-568.2-D standards in position as per specification no.WG-ELVC/PC 121 Supplying and installing LSZH sheathed HDPE insulated copper cat-6A cable suitable for networking compliant with ANSI/TIA-568.2-D standards in provided conduit/casing-n-capping as per specification no. WG-ELVC/NC Networking Accessories (WG-NAS) 122 Supplying, installing and testing UTP connector (RJ-45) as per specification no. WG-NAS/UTPC. 123 Supplying and fixing Cat 6, 24 port patch panel with keystone jacks compliant with ANSI/TIA/EIA 568.C.2 & ISO/IEC 11810 complete as per specification no. WG-NAS/PP 124 Supplying and fixing 24 ports light guide unloaded interconnect unit, rack mounted type, with adapter panel for termination of optical fiber cables in provided U rack complete as per specification no. WG-NAS/ LIU 125 Supplying and fixing 6U wall mount rack (Dimension-DxWxH – 500x550x347 mm) as per specification no. WG-NAS/RAK 126 Networking Components (WG- NWC) 127 Supplying, fixing, and configuring 8-ports managed gigabit, layer-2 switch, 10/100/1000 base-T, PoE smart switch plus 2 SFP erected in provided rack compliant with IEEE 802.3 standards complete. 128 Supplying, fixing, and configuring 24 ports, PoE switch compliant with IEEE 802.3 standards with min. 193W PoE capacity with 4GE SFP uplink in provided rack as per specification no. WG-NWC/ENS 129 Supplying, fixing, and configuring broadband router with all accessories on provided rack 130 Supply, Installation, Testing & Commissioning of 2MP, IP Camera, 1/2.8 type CMOS image sensor, fixed lens 2.8 / 3.6 mm, H.265 / H.264 & MJPEG triple-stream encoding, 25/30fps@1080P (1920 ×1080), Max IR LEDs length 30 m, IP66 rated, Fixed Dome Camera. CCTV camera - IP - Dome - Cpplus / Hikvision make 20mtr - 2.8 / 3.6mm lens 131 Supply, Installation, Testing & Commissioning of 2MP, IP Camera, 1/2.8 type CMOS image sensor, fixed lens 3.6 mm / 4 mm, H.265 / H.264 & MJPEG triple-stream encoding, Max. IR LEDs length 30 m , IP66 rated, 25/30fps@1080P (1920 ×1080), Support ICR for day time and night time operation, Fixed Lens Bullet Camera. CCTV camera - IP - Bullet - Cpplus / Hikvision make 30mtr - 2.8 / 3.6mm lens 132 Supply, installation, testing and commissioning of UL Listed Network Video Recording System (in multiple of 32 channels) should be capable of recording 32 cameras at D1 resolution @ 25 FPS for 100% recording for 30 days. Required HDD for the same to be considered. CCTV NVR 32 channel - Cpplus / Hikvision make + 8TB HDD - Toshiba / WD make Supply , Laying , Testing & Commissioning of 42” LED Display with necessary connectors , inter linking cords etc. complete as required. 133 Supply, Installation, Testing & Commissioning of Cat-6 patchcord-1Meter long. Supply, Installation, Testing & Commissioning of Jack panel 24 port fully loaded. 134 IO Box + Plate + RJ45 jack. 135 PVC box 5*5
Contract Date: Dec 12, 2025 Contract Value : 4.08 Crore
Government Departments No of Bidders 6
Maharashtra View Result →
26.
Defence #8319124 AOC
Tender For Provision Of Blast Pens, Taxi Track And Allied Infrastructure At Tanda.; 1 Sch A Part-I(Building Work):-This Schedule is not Pre-Priced by MES and the Pre-Priced rate indicated as Rs. 0.00 under col.5 signifies this fact only. 2 Construction of block of RCC Blast Pen (Single type) complete all as shown on drawings and as specified. 3 Construction of block of RCC Blast Pen (Twin type) complete all as shown on drawings and as specified. 4 TotalAmount of Sch A Part - II (Site Clearance Work) 5 TotalAmount of Sch A Part - III (Internal Electric Supply Work) 6 TotalAmount of Sch A Part - IV (Protective Work) 7 TotalAmount of Sch A Part - V (Area Drainageand Pusa Grass Work) 8 TotalAmount of Sch A Part -VI (Road, Path and CulvertWork) 9 TotalAmount of Sch A Part - VII (External Electric Supply) 10 TotalAmount of Sch A Part - VIII (Fire Fighting System Work) 11 TotalAmount of Sch A Part - IX (PQC Taxi Track and Blast Pens Work) 12 Sch A Part - X (Misc Items of work) Note : This Schedule is not Pre-Priced by MES and the Pre-Priced rate indicated as Rs. 0.00 under col.5 signifies this fact only. 13 Good earthfor filling obtained from out side MoD Land to site including spreading, levelling in layer not exceeding 30cm, ramming and consolidation complete all as specified and directed. 14 Supply only elevated type omni-directionaltaxiway light fixture (10W, 2 cd) complete, blue lens, connected secondary lead including supply of LED lamps, and other standard accessories etc., complete all as specified and directed. 15 Supply only 6 Sqmm single core 5 KV grade PVC insulated & PVC sheathed, antitermite & anti-rodent, multi-stranded copper conductor,airfield lighting cable confirming to IS 1554 (Part-II), complete all as specified and as directed. 16 Supply only 4 sqmm 2 core PVC insulated PVC sheathed, AFL secondary lead made out of unarmoured copper conductor 1100V grade cable for connection to airfield light fixtures, complete all as specified and as directed. 17 Supply only 15 W, 5KV, 50 Hz individual lamp series type Isolating transformer encapsulated in TPR/TPE with primary and secondary connection leads complete, complete all as specified and directed. 18 Supply only 5 KV grade ESNA connector and suitable for field attachment with 5KV grade PVC insulated, PVC sheathed single core 6 sqmm copper conductor cable, complete all as specified and directed. 19 Supply only MS housing box of single chamber as per specification and drawing of size 330 mm x 330mm x 450 mm (H), 10 mm thick with 220 mm dia clear opening on top surface for installation of AGL fittings, complete all as specified and directed. 20 Supply only M.S. dummy plate of 10 mm thickness with rubber gasket suitable for installation on the existing transformer CI housing box of 330mm dia with 6 No holes suitable to receive & supply suitable M10 x 30/40 SS bolts, plain washer etc; complete all as specified and directed. 21 Supply only50mm dia, HDPE pipe as per IS:4984:2016, material Grade:PE 80, PN 10, complete all as specified and directed. 22 6 SWG dia G.I. wire along with UG cable in direct Ground/Trench/ HDPE/GI Pipe etc complete complete all as specified and directed. 23 Providing and laying earth connections, from earth electrode with 6 SWG dia, G.I wire in 15 mm dia G.I pipe from earth electrode, complete all as specified and directed. 24 Supply only 1 sqmm bare copper conductor for earthing of light fittings, complete all as specified and directed. 25 Installation of MS housing boxes with a base PCC 1:3:6, type C-I using 20mm graded crushed stone aggregate of size (330 x 330 x 450)mm all round PCC 1:2:4, type B-I using 20mm graded crushed stone aggregate 150mm thick , the top sloped with 1:2:4, type B-1, using 20mm graded crushed stone aggregate including providing and fixing 300 mm long 15 mm dia. medium grade GI pipe with check nut for drainage of water including excavation and earthwork etc; complete all as specified and directed. 26 Installation of elevated type runway light fixture including installation of isolating transformer, complete all as specified and directed. 27 50mm dia HDPE pipe in the soil by excavation up to 80 cm and refilling the earthwork and make good including coupling, splicing, jointing of pipe etc complete as required. 28 PVC insulated and PVC sheathed/XLPE power cable of 1.1KV to 5KV grade 35 sqmm in the existing RCC/GI/HUME/METAL/HDPE pipe etc. complete all as specified and as directed. 29 Supply, Installation, Testing, Commissioning ofGuidance signage board (IP 65 protection) complying ICAO standard of various sizes fabricated from anodized aluminium profile structure & 2mm thick aluminium sheet, 4mm thick long life imported non-specular surface polycarbonate signage sheet, symbols of sign shall be made of self-adhesive 3m film applied on face of polycarbonate sheet and all reflector sheet for light reflection if required. Board shall be illuminated with linear LEDs & driver(s) including all other accessories, suitable converter to operate on 2.8 Amp to 6.6 Amp AC constant current as incoming supply, mounting legs with breakable coupling & base frame, secondary leads, providing cement concrete foundation of suitable size & depth for each unit, providing pedestal up to 1.5 mtr all around the signage with PCC 1:2:4, type B-1, using 20mm graded crushed stone aggregate of 150 mm thick & finish with neat cement plaster including supply and installation of suitable single capacity/ wattage electronic converters etc complete as required, complete all as specified and as directed. 30 Cutting of surface with kerf cutting machine of suitable size & depth for laying of GI/HDPE pipe/connecting lead in bituminous/PQC area of runway including kerfing, chiselling, cleaning and refilling the groove with suitable PCC and sealant material as required and making good including primer etc; complete all as specified and as directed. 31 Communication cable PVC insulated copper conductorunarmoured cable, 1100 volts conforming to IS:7098 of size 1.5 sqmm 8 core, complete all as directed 32 Brick masonry valve pit of size 900mm x 900mm x 900mm (internal dimensions) including excavation and earthwork in any type of soil, plastering all wall surfaces internally and flush pointing to brickwork externally as the work proceeds complete including angle iron 50x50x6mm frame, MS sheet cover 3.15mm thick with 12mm dia handle, locking arrangement and painting with two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer, complete all as specified and as shown on drawings. 33 Cutting the existing MS Pipe line upto 150 mm dia bore by necessary welding or any other means complete for branch connection including provision of tee of required size. Complete all as directed. 34 Copper wound transformer 11 KV/433 Volts, 3 phase 50 Hz, 500 KVA capacity, outdoor type, with off load tap changing arrangement on HT side to vary secondary voltage upto 7.5% in step (+ or -) 2.5% including suitable cable entry boxes both on HT to receive 95 Sqmm 3 core XLPE cable and on low voltage side to accommodate XLPE cable of suitable size complete in all respect with standard accessories and fitment, confirming to IS:1180- 2014, Part-I . Primary side Delta and secondary side Star. The sailent feature of transformer shall be as follows:-(a) Transformer shall be oil immerse, naturally self cooled copper wound, winding core type MS radiator cooled tank complete with first fill of transformer oil plus 5% spare oil as per IS:335 of 1980 with cooling system. The temperature of oil shall not rise more than 50 degree centigrade to amient temp and 55 degree centigrade of winding. Transformer shall be painted with two coat of epoxy paint as per IS-632. 35 (b) Transformer shall be provided with the followings:-(i) Rating and diagram plate.(ii) Earthing terminals 2 Nos.(iii) Lifting lugs.(iv) Thermometer pocket.(v) Air release hole with plug.(vi) Tap changer with locking provision.(vii) Oil temperature indicator. 36 Construction of brick masonary platform 3m x 2.5m x 1.2m with XPM fencing with weight not less than 4kg/Sqm and angle iron 50x50x6mm for support gate with locking arrangement, PCC 1:2:4 type B-1, using 20mm graded crushed stone aggregate as in floor including excavation and earth work complete, platform white washing, Painting of fencing and frame work complete all as specified and as shown on drawings. 37 DWC HDPE pipe 50mm inner dia (double wall corrugated) confirming to IS: 14930 (part-II) alongwith necessary snap fit coupler for interconnection suitable for HT/LT cable complete all as specified and directed. 38 Supply, Install, testing and commissioning LT distribution board (Outdoor Type) suitable size, CPRI Approved factory made, Single door, Cubical type, Compartmentalized design, back door, openable, fabricated out of 3.15 mm thick CRCA steel sheet, weather / dust/ vermin proof, suitable spaced totally enclosed in chamber, earthing arrangement, locking arrangement with one no lock with duplicate key duly painted with powder coated paint having danger notice boards and earthing terminals on both sides and including providing the following items incl connection of all incoming and outgoing cables using suitable size lugs and glands, Spreader terminal set, control wiring, panel to be mounted on cable trench if required with base channels as required and suitable foundation of panel with PCC 1:2:4complete in all respect all as specified & directed by Engineer-in-charge including comprising of following items:- 39 (i) 4 No Aluminium Busbars of high conductivity, 3 No for phase (R,Y,B) rating 1500 amp and 1No for neutral rating 1500 Amp, Mounted on DMC support with heat shrink sleeve - 1 Set.(ii) ACB 4 Pole, 415 V, with Thermal Magnetic Release (Manual Fixed type) of capacity 1000 Amp– 1 No (incoming)(iii) On load changeover switch 1000 Amp, 4 Pole - 01 No(iv) MCCB 4P 400 Amps 50 KA 415 V 50 Hz - 2 No (for Panel No 1 & 2)(v) MCCB 4P 250 Amps 50 KA 415 V 50 Hz - 1 No (for Panel No 3)(vi) Multifunction meter, three phase, digital type, with parameters like voltage, ampere, frequency, PF etc, and with suitable rated CT’s complete including selector switch for three phase etc (vii) Indication Lamp (R,Y,B), LED Type, With toggle switches – 1 Set of Three 40 Supply, Install, Testing and commissioning LT distribution board (Indoor Type, Flame Proof) suitable size, CPRI Approved factory made, Single door, Cubical type, Compartmentalized design, back door, openable, fabricated out of 3.15 mm thick CRCA steel sheet, weather / dust/ vermin proof, suitable spaced totally enclosed in chamber, earthing arrangement, locking arrangement with one no lock with duplicate key duly painted with powder coated paint having danger notice boards and earthing terminals on both sides and including providing the following items incl connection of all incoming and outgoing cables using suitable size lugs and glands, Spreader terminal set, control wiring, panel to be mounted on cable trench if required with base channels as required and suitable foundation of panel with PCC 1:2:4complete in all respect all as specified & directed by Engineer-in-charge including comprising of following items :- 41 (i) 4 Nos Aluminium Busbars of high conductivity, 3 Nos for phase (R,Y,B) rating 300 amp and 1No for neutral rating 300 Amp, Mounted on DMC support with heat shrink sleeve - 1 Set.(ii) MCCB 4P 163 Amps 36 KA 415 V 50 Hz – 1 No (incoming)(iii) MCCB 4P 63 Amps 25 KA 415 v 50 Hz - 2 No(for Industrial socket)(iv) 3 Phase and Neutral Industrial Plug and Socket 63 Amps - 02 No (v) Single Phase and Neutral Industrial Plug and Socket 32 Amps - 01 No (vi) MCB SPN 63 Amps 10 KA 220 V 50 Hz - 1 Nos(Single Phase Industrial Socket)(vii) Multifunction meter, three phase, digital type, with parameters like voltage, ampere, frequency, PF etc, and with suitable rated CT’s complete including selector switch for three phase etc (viii) Indication Lamp (R,Y,B), LED Type, With toggle switches – 1 Set of Three 42 Supply, Install, Testing and commissioning LT distribution board (Outdoor Type) suitable size, CPRI Approved factory made, Single door, Cubical type, Compartmentalized design, back door, openable, fabricated out of 3 mm thick CRCA steel sheet, weather / dust/ vermin proof, suitable spaced totally enclosed in chamber, earthing arrangement, locking arrangement with one no lock with duplicate key duly painted with powder coated paint having danger notice boards and earthing terminals on both sides and including providing the following items incl connection of all incoming and outgoing cables using suitable size lugs and glands, spreader terminal set, control wiring, panel to be mounted on cable trench if required with base channels as required and suitable foundation of panel with PCC 1:2:4complete in all respect all as specified & directed by Engineer-in-charge including comprising of following items :- 43 (i) 4 Nos Aluminium Busbars of high conductivity, 3 Nos for phase (R,Y,B) rating 200 amp and 1No for neutral rating 200 Amp, Mounted on DMC support with heat shrink sleeve - 1 Set.(ii) MCCB 4P 100 Amps 36 KA 415 V 50 Hz – 1 No (incoming)(iii) MCCB 4P 63 Amps 25 KA 415 v 50 Hz - 1 No(for Industrial socket)(iv) 3 Phase and Neutral Industrial Plug and Socket 63 Amps - 01 Nos (v) Multifunction meter, three phase, digital type, with parameters like voltage, ampere, frequency, PF etc, and with suitable rated CT’s complete including selector switch for three phase etc (vi) Indication Lamp (R,Y,B), LED Type, With toggle switches – 1 Set of Three 44 Hangar Aviation light fitting single top LED type colour red suitable to 230V AC flameproof cum weather proof with IP66 degree of protection, red colour including all necessary fixing arrangement complete all as directed. 45 Supply, installation, testing and commissioning of minimum 500 KVA0.8 PF of corresponding400 KW diesel engine driven Generating set with alternator out put Voltage 415 Volts +/- 1% at set value of 415 V at a frequency 50HZ +/- 0.5% with suitable standard control panel, allmounted in acoustic enclosure with AMF panel as per manufacturers design and specification as per latest approved CPCB-04 norms confirming to thedetailed specifications appended below:-(I)ENGINE (a) General: Suitable four stroke compressed ignition, radiator water cooled, Turbocharged aspiration, continuous duty with 10% overload capacity for any one hour in 12 hours running, 50°C intake air temperature, CPCB-04 approved Engine developing power to generate Minimum 400 KW at alternator operation at 1500 RPM coupled to alternator mounted on Channel Iron base frame with in built removable fuel tank of capacity not less than 12 Hrs consumption capacity at 75%load or more as per manufactures recommendation. The prime mover provided should be as per IS specifications having engine overload protection.(b) Air intake system :Should comprise of dry type intake air filter mounted on engine, one in number vacuum indicator mounted on intake piping. 46 (c ) Exhaust System: Should comprise of one exhaust manifold, dry type, mounted on engine, one exhaust silencer which should be positioned in such a way that the exhaust gas is not sucked by the fan on the radiator, thereby affecting the cooling system. The silencer should cater to the noise level tolerance prescribed in the relevant BS/IS. The silencer should be provided with flapsit will open only when the generator is running. The complete exhaust system shall be properly supported so that entire lot of the exhaust system shall not fall on the DG Set.(d) Fuel System: Should comprise of disposal type element fuel filter, pressure type fuel pump mounted on engine, non return check valve in fuel supply and drain lines, wire braided hose between filter and pump, fuel system with suitable capacity full authority electronic engine electronic governor and engine mounted actuator. The fuel tank must have proper locking arrangement with level indicator and to be integrated with base frame. 47 (e) Cooling System: Should comprise of radiator designed and tested for 50o C ambient temperature with 7 PSI pressure cap mounted on base rail. The thermostat installed in the engine coolant outlet, fresh water pump mounted on engine, fan and fan hub mounted on engine. A reservoir of 50% of radiator capacity to replenish coolant by gravity (as and when required) is also to be provided.(f) Lubricating System: Should comprise of lubricating oil sump mounted on engine, gear driven lub oil pump mounted on engine, lubricating oil cooler-fresh water cooled integral with engine cool out circuit mounted on engine, oil filter lubricating with cap and lubricating oil dip stick for oil level check mounted on engine. The system should be capable of feeding lube oil to the main end& large end bearings, cam shaft, valve rocker gear and all moving parts. 48 (g) Starting System: Should comprise of suitable voltage DC electrical self starter mounted on engine, with suitablemaintenance free batteries -2 Nos 2 Nos. 25 Plate, 180 Amps, 12 Volts Battery with one set of connecting leads of 75 sq mm Size Copper Cable to be mounted in trays (having rubber insulation) on the main frame or the capacity as per specification of manufacturer. It should have the provision to charge the battery from external sources during static condition and while running of the generator.(h)AC Generator:The generator shall be horizontal and foot mounted, minimum 500 KVA, 415 Volts, 3 phase, 4 wire, 0.8 PF, 50 HZ, separately excited, self regulated, brushless AC generator, suitable for an ambient temperature of 50° C with IP-23 enclosure class H insulation and temperature rise limited to class H as per following technical details(i) Type : Brush less AC Generators(ii) Output rating minimum : 500 KVA at 0.8 lagging(iii) Output Voltage: 415 ± 1% under all loading conditions.(iv) Output frequency : 50Hz ±0.5% up to 0.8 lagging.(v) No of Phases: 3 phase with 01 Neutral (4 wire)(vi) Mounting : Horizontal foot mounted. 49 (vii) Enclosure :Minimum IP-23 / Drip proof and screen protected.(viii) Automatic voltage regulator.(ix) Class of insulation-H.(x) AREP exciatation system. (j) BASE FRAME: MS Chanel fabricated frame of suitable size rigedly weldedas recommended by the manufacturer shouldbe suitable to mount the engine, alternator, radiator and anti-vibration pads.(k) CONTROL PANEL: (i) Shall be indoor type manufactured with 14/16 guage CRCA sheet and is powder coated for weather-proof and long lasting finish consisting of microprocessor power command controller, Aluminium busbars with suitable capacity with incoming/outgoing terminals, indicating lamps for Load ON and Set Running, instrument fuses duly wired and ferruled, MCCB of suitable rating with overload and short circuit protections etc. complete all as specified and directed. 50 (ii) Standard Auto Mains Failure panel suitable to activate the DG set automatically on power failure shall be provided with necessary accessories like switchgears, meters and other accessories. The panel shall be designed for manual operation if required.The control panel shall consist of all the controls of the alternator as required and recommended by standard codes of practice and shall be originally manufactured along with the alternator, floor mounted, cubical type with LT switch board and complete with internal wiring. Suitable arrangement shall be made for joining incoming cable and for connecting the bus duct on the outgoing side. This shall be dust/ vermin proof.(l) AMF PANEL: Sheet steel enclosed cubical typepanel, LT 415 Volts 3 phase 50 Hz, made out of 3.15 mm thick CRCA sheet for body & 2 mm thick for partitions ,consisting of suitable rated contactors, 1 set TPN bus links from incoming and outgoing cable termination, AMF Relay, Volt meter, diameter with selector switches, Multifunctional Energy meter, Generator protection relay of L&T make, CTs and 3 Phase indicating lamps, timers etc all as per latest engineering practices. 51 Note :- The cost of control cables from engine Control panel to AMF panel shall be deemed to be included in the cost quoted.(m) Accessories :-(i)01 No standard mechanical and electrical tool box.(ii) Internal covered tube lights.(n) Acoustic Enclosure:-Specially designed to meet CPCB norms 75dBA @ 1 mtr at 75% load under free field conditions. The Acoustic enclosure is made of CRCA sheets and a structural/sheet metal base with high quality noise absorbent and fire-retardant grade acoustic insulation material (P.U.Foam) complying to IS 8183 with two point lifting handles(o)Internal Lighting: Tube lights with protective mesh around it to be fitted inside the container for proper illumination.(p) Doors :The enclosure will be provided with suitable doors on the side and rear to enter the enclosure during operation and maintenance.All doors will be provided with lock and handles for opening/ closing the doors, retainers for holding the panel door. 52 (q) Painting SchemeSuperlative fade resistant paint can last longer in through whether conditions(r) Lifting/ Transportation arrangements :-Container with suitable corners will be provided to lift the DG set along with container.(s) Trials:-Trials on site should be given as per load tests prescribed and all functional trials should be shown.(t) Material and Labour for making PCC Foundation of DG set size as per manufacture recommendation. 53 Earthing complete with galvanized steel earth plate electrode 600mm x 600mm x 6.0mm thick buried directly in ground ( earth pit not less than 2.25 mtr below normal ground level ) with top edge plate not less than 1.5 metre below normal ground level connected to galvanized earth strip of size 32x6mmas earthing lead by means of bolts, nuts, chuck nuts and washers of galvanized iron earth lead with 15 cm thick alternate layers of charcoal dust & common slat including PCC pit in PCC 1:2:4 type B-1, RCC covermade out of cement concrete 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) reinforced with TMT steel bars 8 mm dia @150 mm c/c both ways with suitable handle andangle iron 40 x 40 x 5 mm frame, GI medium grade watering pipe 20 mm bore and funnel with wire mesh light grade protection pipe 40mm bore up to main board complete as shown on electrical plate No 3 of MES Sch 2009 (Part-I) and testing on completion complete all as specified and directed by the Engineer-in-Charge. Note: - On testing after completion of earthing, if desired earth resistance is not obtained, the earthing will be re-done by the contractor at his own risk & cost to the entire satisfaction. 54 Earthing complete with galvanized steel earth plate electrode600x600x6mm buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of earth plate not less than 1.5m below normal ground level connected with galvanized iron earth lead wire 4mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel complete with 15mm dia GI light grade protection pipe, 20mm dia GI medium grade watering pipe with funnel including charcoal, dust, salt, PCC M-15 type B1 in pit with angle iron (25x25x3)mm frame work with precast RCC 1:2:4 type B-1 cover reinforced with 8mm dia TMT bars @ 150mm C/C both ways and 12mm dia MS fabricated handle, test point etc. in and including light grade GI protection pipe 20mm bore up to 7.5m length for drawing in earth lead wire, all as shown in electric plate No. 3 of SSR Part-I complete with necessary earth work in any type of soil, removal of soil to a distance not exc. 50m, testing on completion complete all as specified and directed.Note:- On testing after completion of earthing, if desired earth resistance is not obtained, the earthing will be re-done by the contractor at his own risk & cost to the entire satisfaction. 55 LED flood light, 120 watt, 230 V, AC outdoor, type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver, lamp and complete fittingand fixturecomplete all as specified and directed. 56 Soil stabilization of 500mm (compacted thickness) in layers, each layer shall not be less than 100mm thick and not more than 200mm thick (compacted thickness) sub grade soil by uniform mixing of cement OPC 43 grade @ 2% by weight of soil as per mix design. Mix design shall also contain recommended quality control tests with their frequency. Relevant provisions of IRC : SP 89-2010will be applicable for process and quality control. Exact quantity of cement shall be arrived after trials on ground to achieve the required CBR /K value duly approved with mechanical means, adding required water, spreading material in layers and blending using mechanical rotovator, rolling and compaction with 80-100 KN static weight, power vibrating roller complete all as specified.Note: Cement shall be measured and paid separately as supply only. 57 Preparing surfaces and applying two coats of road marking paint (water based) on pavement surfaces as in centre line marking, edge marking, threshold marking, touch down marking (Plan-Alpha) and all other marking for runway aprons, taxiways etc; complete all as specified and directed. 58 Grassing with Pusa selection No. 1 type grass including watering and maintenance of berm lawn till completion weeds and fit for moving including fine dressing of ground in requred level and flooding with water and the component mentioned should include termite treatement of dibbled area chemical fertilizers and vermi compost/green magic etc; complete all as specified and directed. 59 Point wiring with FRLSH insulated unsheathed multistranded copper conductor single core cable, 1100 volts grade (ISI marked) of size 1.5 sqmm drawing into concealed stove enamelled steel conduit, 1.6mm thick not less than 25mm dia (ISI marked) concealed in RCC wall for flameproof light point controlled by one switch including provision of 1.5 sqmm FRLSH insulated unsheathed copper conductor cable, multistranded single core as earth wire to common earth & connecting to flameproof switch or CI sunk box making the distributed surface to match the existing specification complete all as specified and as directed. 60 Flame proof, weather proof distribution board, 8 way with and including 06 Nos flame proof SP MCB 6-16 Amps and 1 No. flame proof MCB SPN 32 Amp alongwith weather proof cover of DB, complete all as specified and directed. 61 Submain wiring with the size of 2x 6.00 sqmm + 1x 6.00 sqmm earth wire of FRLSH, smoke free, non toxic, non corrosive insulated stranded copper conductor with UNILAY constructionsingle core cable 1100 Volts grade ISI marked TEC and FIA approved and drawing in concealed / surface / recessed in ERW steel conduitjunction with all accessories , wiring complete forswitches, socket,etc complete. Note:- Rates forsteel conduit and any type ofjunction,Elbows, Tees, Bends, and any type of jointing / fixing accessories such as coupler locknuts, Saddle / Pipe hookes etc is deemed to be included in quoted rate.Note: Two run of 6 Sqmm single core copper conductor cable and one run of 6 Sqmm single core copper conductor cable as earth continuity and one run of ERW steel conduit shall be measured as one unit. 62 DWC pipe (double wall corrugated) confirming to IS: 14930 (part-II) alongwith necessary snap fit coupler for interconnection suitable for HT/LT cable (110mm/90mm as diameter) all spedified and directed.
Contract Date: Nov 25, 2025 Contract Value : 51.33 Crore
Statutory Bodies & Commissions/Committees No of Bidders 5
Jammu And Kashmir View Result →
27.
Housing Urban and Rular Development #8133185 AOC
Tender For General- Smart Class Room - Brennen College Balance Work - supply installation testing and commissioning Of Electronics Items For Smart Class Room At Brennan College, Thalassery, Kannur- General Electronics Work-1 Supply and Installation of Smart class Room. 1.001 OD44161/2025-2026:Supply and installation 19 inch 17U Floor mounted Audio rack with 600 mm depth and having front glass door and rear Ms doors, 1 set of vertical Power Distribution Box with min 6 nos. of 5A, 3- pin AC sockets, and 2 Nos. of cooling fan including the cost of Horizontal cable manager. (Approved Make: HCL,Netrack,President, Valrack) 1.002 OD37580/2025-2026:SITC of Medium Wattage (80W) PA AMPLIFIERS having 80W RMS at 10% THD, Output Regulation; less 2 dB, no load to full load at 1kHz, Input Channels; 3 x Mic 1.0mV/4.7kOhm, 1 x Aux 100mV/470 k Ohm, Frequency Response;65-15,000Hz ±3dB, Signal to Noise Ratio; 60dB, Tone Controls; Bass: plus or minus 8dB at 100Hz, Treble: plus or minus 8dB at 10kHz, Speaker Outputs; 4/8/16 Ohm 70V and 100V, Digital Player; MP3 Player with USB, SD and MMC Card Reader, Bluetooth and FM, Power Supply ; AC: 220-240V 50/60Hz, DC: 12V (12V Car Battery), (Approved make: Ahuja SSB-80DFM, Studio master) 1.003 OD38655/2025-2026:Supply and installation of 30W PA wall speakers with mounting bracket and all hardware accessories having Rated Power taps :30W/20W/15W/10W 8Ohm on 100V, Frequency Response :75Hz-20KHz , Sound pressure level : 87dB (Approved Model : AHUJA ASX 312BT/ Studio master ) 1.004 OD29179/2025-2026:Supply of Professional PA microphone having frequency response 50 Hz to 18000 Hz, Impedance 300 ohm, sensitivity 2.5mV/Pascal, with professional type XLR connector and 10 Meters shielded Mic. Cable with 3 year warranty (Approved Model :Ahuja PRO+3200/ Studio master) 1.005 OD29177/2025-2026:Supply of Duet UHF Wireless Microphone having 50-16,000Hz frequency response, individual XLR channel, display for frequency response and two transmitters(microphones)used at the same time with 3year warranty.(Approved Model: Ahuja AWM 700 UHL/ Studiomaster XR 40HL) 1.006 OD29169/2025-2026:Supply and Installation of Wireless Presenter having the following features, batteries operated, Connectivity Type wireless, Wireless Type and 802.11a etc., USB Hardware Platform, Included Components , Wireless Presenter TXD/RXD, 2 AAA batteries, Carrying case, Quick-start guide. Durable to long last and have warranty for 3 years. (Approved: Logitech, Canon) 1.007 OD29168/2025-2026:Supply and Installation: Projector Ceiling Mount including mounting hardware and accessories, 3ft (l .5ft length extendable up to 3 ft.), Universal type compatible with all projector brands and models, Pole Material - Aluminum, Mounting Bracket and Legs made of Cold roll steel powder coated- white, capable of fixing on all type of Roofing; 1.008 OD29182/2025-2026:Supply and fixing of face plate on the wall/wooden rack having HDMI port and providing connection from Projector to face plate through PVC conduit for HDMI connection . (Approved make : Logic, MX, Honeywell) 1.009 OD29170/2025-2026:Supply and Installation of HDMI Cable (5 mtr) P/N: 1.4/2 V high speed HDMI cable with 4K Gold plated connectors that must be corrosion resistant, HDMI male to male connectors, non-slip and non-screw connectors, should be able to withstand minimum pull force, Conductors 28 AWG copper wire, PVC Jacket, shielding level triple and shielding type Aluminum-Mylar, Dust cap on both ends, supports 1080P video resolution, supports 0.2GB bandwidth and ROHS compliance; Warranty: 3 year onsite. (Approved Make: Honeywell, Logic) 1.01 OD29173/2025-2026:Supply and Installation of HDMI Cable (15 mtr) P/N: 1.4/2 V high speed HDMI cable with 4K Gold plated connectors that must be corrosion resistant, HDMI male to male connectors, non-slip and non-screw connectors, should be able to withstand minimum pull force, Conductors 28 AWG copper wire, PVC Jacket, shielding level triple and shielding type Aluminum-Mylar, Dust cap on both ends, supports 1080P video resolution, supports 0.2GB bandwidth and ROHS compliance; Warranty: 3 year onsite.(Approved make: Honeywell, Logic) 1.011 OD47040/2025-2026:Supply and installation of good quality 5meter AUX cable with suitable connectors at both end 1.012 OD66379/2025-2026:Supply and Installation of multimedia Projector with WiFi having the following minimum specifications 1. Method of Projection : 3LCD /DLP 2. Brightness :3500 ANSI Lumens 3. Contrast Ratio :16000:1 4. Resolution : Full HD 1080p, 1920 x 1080 5. Aspect Ratio : 16:9 6. Throw Ratio : 1.22 - 1.47 7. Interfaces : USB 2.0 Type A, USB 2.0 Type B, Wireless LAN 802.11 b/g/n built-in, VGA in, HDMI in (2x), Composite in 8. Warranty : 3 years onsite (Approved Make: Epson EB- FHO6, Benq,Casio ) 1.013 OD39861/2025-2026:Supply and Installation of good quality 6ftx4ft wall mountable motorized projector screen with necessary wall mounting accessories as per the site conditions. (Approved make: Suvira, Logic, Liberty) 1.014 OD29175/2025-2026:Supply and Installation of good quality 8 x6 feet Motorised Projector Screen with necessary wall mounting accessories (Approved make: Suvira, Logic, Liberty) 1.015 OD29174/2025-2026:Supply and drawing of 2 X 1.5 Sq.mm 650/1100 V grade PVC insulated stranded copper conductor conforming to IS694 part-I 1990 through the conduit including the cost of accessories ( Havells, finolex, V guard) 1.016 1.21.2:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm 1.017 1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm 1.018 OD29171/2025-2026: Supply of Premium Quality Three Pin Universal Multi Plug Extension Board with Individual Switch and Safety Shutter, surge Protector etc having LED Indicator and operates on 230VAC 50Hz capable to carrying 16A current. The given Component must contain three core cord having 3-meter (1.5sq-pvc coated) in length and made up of universal socket consisting of 4 Way Outlets, each carrying 6A minimal flow rate, durable to long last. 1.019 OD56394/2025-2026:Supply and installation of 1.0KVA Line Interactive UPS with 2 Nos of 12V/7Ah Inbuilt battery and having 3 year warranty . Approved Make:-Numeric, Microtek, Hykon, Delta 1.02 OD29185/2025-2026:LS provision for the dismantling of unwanted cables, conduits, cords connectivity during the execution of false ceiling of smart classes and fixing of projectors Including all charges like making up other system connectivity like Computer network, Audio network mesh and hazards sticker etc owing to the changes made when the class rooms are subjected to modification. The Vendor/Bidder must be fetching all the live data and photos of existing hardware and firmware including dedicated live IP/PA if necessary before the execution of Civil activities like, dismantling, repositioning or any other activities which are related to the given task. Organized the workplace and trash out all the junks after the completion of the same. 1.021 OD29181/2025-2026:LS provision for minor electrification including proper connection from UPS to Projector and other equipment, items such as three phase socket, circuit breaker (dual pole for output), appropriate stranding class of cables and conduit etc. need to be procured if necessary and it should be as per the norms of PWD. Note:- Make sure the proper working of newly structured LAN and other items 2 Supply and Installation of LAN 2.001 OD44032/2025-2026:Supply and installation good quality 6U wall mountable Network Rack with 500 mm depth and having front glass door and rear Ms doors, fitted with 1 set of Horizontal cable manager, 1 set of ISI standard Power Distribution Unit, with min 6 nos. of 6A, 3-pin AC sockets, and 2No. of cooling fan. Approved Make:HCL,Netrack,President, Valrack 2.002 OD39898/2025-2026:SSupply and Installation of Rack Mountable, Smart Managed, 10/100/1000 Mbps, 24 port All PoE Giga Ethernet Switch with 2 Nos. of SFP port, and having min. 190W power handing capacity, in the existing 19 inch Rack (Approved Make:-Netgear / Cisco/Juniper/HP) 2.003 OD39902/2025-2026:Supply and fixing of UL Certified 24 port patch panel fully loaded with Enhanced CAT-6 Modular type as per EIA/TIA-TSB 40A specification for interconnecting servers and clients, including termination charges. (Approved Make: Systimax, Molex, Panduit, R and M ) 2.004 OD29186/2025-2026:Supply, laying, certification and documentation of 4 pair UTP LSZH Flame Retardant CAT-6 Data Cables through the PVC Conduit, It should have 23AWG solid copper wire, PE Insulated casing, Two colored insulated conductors twisted together to form a pair, Cable can be offered UV resistance, hydrocarbon resistance, oil resistance, anti-rodent and anti-termite properties etc, IEC and EN based standardization for Flame Retardance, Halogen Free, No Corrosive Gas and minimum Smoke Emission etc, (Approved Make: Actassi, Systimax, Molex, Panduit, R and M, Commscope ) 1 run of Cable 2.005 1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm 2.006 1.21.2:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm 2.007 OD29201/2025-2026:Supply and providing 1Mtr CAT-6 Giga UTP LSZH patch cord. (Approved Make: Actassi, Belden,, Molex, Panduit, R and M ) 2.008 OD29203/2025-2026:Supply and providing LSZH 2Mtr CAT-6 Giga UTP patch cord . (Approved Make: Actassi, Belden,, Molex, Panduit, R and M ) 2.009 OD29200/2025-2026:Supply and providing 3Mtr CAT-6 Giga UTP patch cord . (Approved Make: Actassi, Belden,, Molex, Panduit, R and M ) 2.01 OD29190/2025-2026:Supply and installation of Optical fiber tray ,Fiber Optic patch cord and splicing of the existing fiber. 2.011 OD47051/2025-2026:Supply, laying, and commissioning of Optical Fiber Cable containing 6 core, 9/125?m, OS2 Type optical fibres in water blocked loose tube, taped, corrugated steel tape armoured (STA) LSZH outer sheathed jelly filled single mode optical fiber cable with LSZH Outer Jacket, anti-Rodent, anti-termite and conforming to the standards, ISO/IEC 11801, ISO/IEC 60332-1, RoHS. ( Approved make: Molex /Delton / Commscope) 2.012 OD56401/2025-2026:Supply and providing 3 mtr full duplex Fiber Optics Patchcord .(Approved Make: Actassi, Belden, Commscope, Molex, Panduit ) 2.013 OD29196/2025-2026:Supply and Laying of 14SWG insulated Steel wire for supporting the Optical Fibre Cable supplied. 2.014 90.12.10.2:Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation50/38 mm or nearest size 2.015 OD47083/2025-2026:Supply and fixing of OFC route marker for identifying under ground optical fiber cable with an interval of minimum 10meter 2.016 OD29193/2025-2026:Supply and fixing CAT-6 information outlet for 1000 Mbps with spring shutter front access for connecting nodes on with concealed mounting box consisting of MS cable store. Preferred Make: Actassi, Belden, Comscope, molex or any other leading brand having mirror features with Compatibility CC. 2.017 OD29195/2025-2026:SITC of wall mountable Wifi access point with a coverage of minimum 100 meters or more,which supports 80 wifi client devices or more,frequency bands:2.4GHz and 5GHz,Wifi standards: IEEE 802.11a/b/g/n/ac,2 Dual band internal antennas, 1.17Gbps or above aggregate wireless throughput, 1x Gigabit and 3x 100Mbit wireline speed. (Approved Make:Grandstream/Netgear/Aruba ) 2.018 OD29194/2025-2026:Supply and installation of Single mode Duplex Gigabit Media Converter to convert 1000BASE-SX fiber to 1000Base-T copper media or vice versa. Designed under IEEE802.3ab 1000Base-T and IEEE802.3z 1000Base-SX standards. (Approved Model: Syrotek/Dlink ) 2.019 OD44057/2025-2026:Supply and installation of 1.0KVA Line Interactive UPS with 2 Nos of 12V/7Ah Inbuilt battery and having 3 year warranty . Approved Make:-Numeric, Microtek, Hykon 2.02 OD29187/2025-2026:Supply and Installation of necessary Electrical accessories for the distribution of mains Power to Rack in structured way, including necessary Sockets, Switches, Electrical PVC boxes etc. and all other accessaries as per the site condition. 2.021 OD29188/2025-2026:Termination of cables in the existing patch panel, testing each and every node point and making permanent labeling at the I/O and on the switch
Contract Date: Oct 19, 2025 Contract Value : 15.26 Lakh
Government Departments No of Bidders 5
28.
Housing Urban and Rular Development #8109900 AOC
DEPOSIT-Melady BP-CCTV at MRF-Supply and Installation of CCTV at MRF center, Meerod Hill, Melady Block Panchayat-General Electronics Work- 1 CCTV 2 OD143657/2025-2026:Supply and installation of 16CH 4K NVR with Max. 384 Mbps incoming/ recording/ outgoing bandwidth, H.265, H.264+, H.264 codec decoding, AI by Recorder: 2-channel face detection or recognition/ 4-channel perimeter protection/ 8-channel SMD Plus, Support 2 SATA HDDs (minimum 10TB Each), 1 x 10/100/1000 Mbps Ethernet port, 2 x USB Ports (1 USB 3.0), HDMI (3840 x 2160)/ VGA (1920 x 1080) Heterogeneous video output, Resolution: 32 MP; 24 MP to QCIF, Protocols: HTTP, HTTPS, TCP/IP, IPv4, UDP, NTP, DHCP, DNS, SMTP, UPnP, DDNS, Alarm Server, Multicast, P2P, Auto Registration, ONVIF (Profile S, T, G) etc. Preferred Make: CP-PLUS or equivalent 3 OD144444/2025-2026:Supply and Installation of 10-Port L2 Gigabit Smart PoE Managed Switch having 8 x 10/100/1000 BASE-T PoE ports, 2 x Gigabit SFP ports, 65 W PoE budget, L2+ Static Routing, Switching Capacity: 20 Gbps, Packet Buffer Memory: 4.1 Mbit, Flash Memory: 32 MB including all accessories Preferred Make: D-Link DGS-1210-10P or equivalent 4 OD143653/2025-2026:Supply and Installation of STQC certified 2MP Dual Light Vandal Dome/Bullet camera Camera having Image Sensor: 1/2.7 inch 2MP PS CMOS Image Sensor (0.9407 Centimeters), Effective Pixels: 1920 x 1080, Minimum Illumination: 0.001 lux @ F1.4 (Color, 30 IRE), 0.0001 lux @ F1.4 (B/W, 30 IRE), 0 lux (IR on), 3.6 mm fixed Lens, video Compression: H.265+, H.265, H.264, Day/Night (ICR), Warm Light Range of 30 m, IR Range of 50 m, Compensation: BLC/HLC/ WDR (120 dB) Bit Rate : H.265: 3 kbps 6144 kbps, H.264: 8 kbps-6144 kbps , Ethernet: RJ-45 (10/100 Base-T), Audio Compression: G.711a, G.711Mu, G.726, PCM, including all accessories. Preferred Make: CP PLUS or equivalent 5 OD287420/2024-2025:Supply and installation of UL listed, ETL verified 1U , 24 port Rack mountable Enhanced Modular type unloaded Patch Panel with rear cable organizer made of cold rolled steel, powder coated, front labelling Facility and suitable for RJ 45 CAT 6/CAT6A Keystones and labelling as required. Preferred make: Molex, Honeywell, Commscope, Norden 6 OD140071/2025-2026:Supply, termination, testing, and commissioning of UL Listed, ETL verified CAT 6 Keystone Jack with dust protection, suitable for 22- 24 AWG bare copper conductor, Minimum 500 insertion cycles and 100 reterminations, as per TIA/EIA 568-B colour code conforming to the standards ANSI/TIA-568.2-D , ISO/IEC 11801, IEEE 802.3, ISO/IEC 60332-1,and RoHS Complaint. Preferred make: Molex, Honeywell, Comscope Norden 7 OD287421/2024-2025:Supply, installation, testing, and commissioning of UL Listed, ETL verified 0.5 meter CAT 6 UTP Patch Cord having LSZH jacket, 24 AWG bare copper conductor UTP 4 pair both end factory Crimped with modular male plugs with minimum 500 insertion cycles terminiated as per TIA/EIA 568-B colour code conforming to the standards ANSI/TIA-568.2 , ISO/IEC 11801, IEEE 802.3, ISO/IEC 60332-1,and RoHS Complaint. Preferred Make: Molex, Honeywell, Commscope, Norden. 8 OD143540/2025-2026:Supply and installation of 32 inch Smart LED Display with 16:9 aspect ratio, 2 x HDMI inputs, USB, Resolution: 1920 x 1080, etc. supplied with all necessary accessories including wall mounting kit. Preferred Make:LG 32SR50F-W, Panasonic, Samsung, Sony. 9 OD287408/2024-2025:Supply and installation of 10TB HDD. Preferred Make: Seagate, WD, Toshiba 10 OD287412/2024-2025:Supply and Installation of wireless mouse. Preferred Make: Dell, Hp, Lenovo, Logitech 11 OD288635/2024-2025:Supply and fixing of 19 inch 6U wall mountable rack with Front Glass door, topand bottom cable entries, Rating: IP20, IK08, double fan provision, depth 500mm all mounting hardware including Horizontal Cable organizer suitable for 19 inch Rack, 2U standard, 230V 6A Inlet Plug type Indian Round Pin socket 6 Nos-1.5 m, Power Distribution Unit, 8A Fuse, Air circulation module 90CFM. Preferred Make: D-Link, Netrack, Valrack or equivalent 12 OD140072/2025-2026:Supply and installation of Screw-In type Outdoor Square Junction Box for CCTV Cameras fixation with Ingress Protection Code of IP65/67 having 4 Inch x 4 Inch x 2.4 Inch or in adequate size of Waterproof Polyvinyl Chloride with all its Cable Gland and screws. 13 OD140073/2025-2026:Supply and installation of IP66 all-weather standard metal built camera casing supplied with all necessary accessories. 14 OD143545/2025-2026:Supply and installation of BIS/CE certified 1KVA line interactive UPS with 120-300 Vac input voltage range, 2 x 7 AH inbuilt battery, Overload, discharge, overcharge protection etc. Supplied with all necessary accessories. Preferred Make:APC, Numeric, Microtek or equivalent 15 OD143549/2025-2026:Supplying and fixing of 6 amps rating, 240/415 volts single power socketwith necessary power cables as required for above saidnetwork/CCTV rack. 16 OD144902/2025-2026:Supply and laying of 5 m HDMI cable v2.0 with ethernet, 3D/4K @ 60 Hz, Ultra HD Resolution,18 Gbps transmission speed, High-Speed, Compatible with all HDMI Devices. Preferred make: MX, Honeywell, Logic or equivalent 17 Cabling 18 OD288632/2024-2025:Supply, drawing. testing and commissioning of UL certified and ETL verified 23 AWG bare copper conductor UTP 4 pair Unarmoured CAT 6 cable with HDPE Insulation Material and LSZH Outer Jacket, conforming to thestandards ANSI/TIA-568. 2-D, ISO/IEC 11801, IEEE 802.3, ISO/IEC 60332-1,ISO/IEC 61034-2,ISO/IEC 61754-2,Colour Code as per TIA/EIA 568-B, RoHS Compliant,transmission performance tested up to 500 MHz or better and Insertion Loss/ Attenuation: 33 dB/100m or better at 250 MHzin the existing conduit as required. Preferred Make: Molex, Honeywell, CommScope, Norden 19 OD288634/2024-2025:Supply, drawing. testing and commissioning of UL certified and ETL verified 23 AWG bare copper conductor UTP 4 pair Outdoor Unarmoured CAT 6 Anti-Rodent, Anti-Termite cable with HDPE Insulation Material UV Resistant and LSZH Outer Jacket ,conforming to the standards ANSI/TIA-568-C.2, ISO/IEC 11801, IEEE 802.3, ISO/IEC 60332-1, ISO/IEC 61034-2,ISO/IEC 61754-2,Colour Code Per TIA/EIA 568-B,RoHS Compliant transmission performance tested up to 250 MHz or better and Insertion Loss/ Attenuation:33 dB/100m or better at 250 MHz in the existing conduit as required. Preferred Make: Molex, Honeywell, CommScope, Norden 20 OD139982/2025-2026:Supplying and fixing of following sizes of medium class PVC conduit, BIS certified,along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm 21 OD139981/2025-2026:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm 22 90.12.10.2:Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation50/38 mm or nearest size
Contract Date: Sep 24, 2025 Contract Value : 2.37 Lakh
Government Departments No of Bidders 3
30.
Defence #8071191 AOC
Tender For Addn /Altn To Room No 39, 40, 65 & 66 At Chandimandir; 1 Powder coated aluminium door frame ofhollow section 100x40mm and including aluminium glazed shutters stiles 95x45mm & having grooves for bush beading and top rail of hollow section 80x45mm .Lock rail of hallow section 115x45mm and bottom rail of hallow section 125x45mm with aluminium butt hinges of size 125mm, aluminium anodised handle 200mm long and aluminium floor door stopper, hydraulic door closer mortise lock 65mm,4 leavers and aluminium and glazing with selected quality tinted glass 4.8mm thick and rubber beading and aluminium beading and PVC bush beading complete all as specified and directed(Note- Thickness of aluminium section not less than 1.58mm and offrs designation / Room Name printed in glass). 2 Fabrication powder coated aluminium air tight sliding type window with AI box frame 65 x35x2 mm shutter with bottom and top rails of section 45x45x2 with 5mm thick selected quality tinted glass pan inclding rebated fixing builder hard ware and fitting springs, glazing clips rubber packing for air locking, anodised AI snap beading screw etc for fixing glass pane in frame shutters cover selected quality glass 5mm thick rubber packing including aluminium grill size of 75x75 mm cast type with aluminium beading, gasket etc complete and stailess steel wire mesh complete all as specified and directed. 3 10mm thick toughned glassglass as in hinged doors, partitions automatic doors and similar work including cutting to shape, drilling holes required,complete all as specified and directed. 4 Double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty , complete all as specified and directed. 5 D type 150mm powder coatedaluminium handle for aluminum door, complete all as specified and directed. 6 Solid 14mm thick wood polymer composite louvers wall paneling (size 192mm x 2900mm x 14mm) fixed to walls with necessary clip, screw / adhesive complete all as specified and directed.NOTE : The wall paneling has to be in conformity with the existing wall paneling at site. Bidders ae requestd to visit the site before quoting their bid. 7 2mm thik PVC sheet fillet/ angle / beading of width 35mm for making frame for wall paneling inclusive of fixing on to wall to make PVC frame as per specification and drawing, complete all as specified and directed at site. 8 Demolition of brickwork built in cement mortar or cement lime mortar, including all quoins, arches, pillars etc but excluding ashlar facings, dressed stone work and precast concrete articles complete all as specified and directed 9 Brick work using old size bricks, straight or curved on plan exceeding 6.00 metre mean radius built in cement mortar 1:6, complete all as specified and directed. 10 Rendering 10mm thick in Cement and Sand mortar 1:6 over brick or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed. 11 Preparation of old plastered surfaces of walls and applying two coats of oil bound distemper overand including a coat of primer complete all as specified and directed. 12 Preparation of new plastered surfaces of walls and applying two coats of oil bound distemper overand including a coat of primer, including 2mm thick (Average) wall care putty and sand papering complete all as specified and directed. 13 Anodised aluminium snap grid frame work for false ceiling including Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long including dismantling ceiling board complete all as specified 14 4mm Non asbestos fibre cement building boards fixed or laid/ inserted to timber/GI/Aluminium framework with screws complete all as specified and as directed. 15 Dismantling floor hearth or wall tiling including cementmortar bedding (but not backing) complete all as specified and directed 16 Coloured vitrified ceramic tiles, light shade,8-10mm thick (square ) , area of each tiles n.exc 0.36 sqm, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile, over15mm thick screed bed in cement mortar 1:6,complete all as specified and directed. 17 All as per serial item No 16 hereinbefore but on skirting / vertical surfaces laid over and including 10mm rendering in cement mortar 1:4, compelte all as specified and directed 18 Taking down chowkats or frame not exc. 1.5 Sqm with shutters, without taking off shutters from the frame,complete all as specified and directed. 19 Taking down chowkats or frame exc. 1.5 Sqm and n exc 4 Square metre with shutters, without taking off shutters from the frame,complete all as specified and directed. 20 Taking down carefully aluminum/copper point wiring on & including hard wood battens, surface conduit and board/blocks etc or through conduits for light , socketor power point ,fan point complete incl fitting such as switches ,sockets, ceiling rose , holder socket, light fitting, regulators and making good disturbed surfaces of wall, floor , ceiling etc and removing materials (other than those for which credit has been given by the contractor) to the MES stores yard for keeping in safe custody complete 21 Material and labour forpoint wiring with approved colour code multi stranded copper conductor, PVC insulated and unsheathed FRLSH cable of size 1.5 Sqmm ,1100 volts grade, two run of single core cable for phase & neutral and one run of single coremulti stranded copper conductor, PVC insulated and unsheathed FRLSH cable of size 1.5 Sqmm ,1100 volts grade for earth continuity conductor to common earth and connected to earth dolly in and including new concealed PVC conduit terminated on and including new modular sunken box and suitable size of frame, cover for mounting switch, socket and regulator fixed on surface flush with wall , comprising ofOne light /bell/buzzer point controlled by one switch or one fan point controlled by one switch &fan regulator, complete all as specified and directed. Note : Unit rate is inclusive of making good the disturbed surfaces by provding by wall putty/POP after mason work and finshing to match the original and nothing extra shall be paid on this account. 22 All as per serial item 21 herein before but for socket outlet 3 pin 5 Amps on same board complete all as specified and directed 23 All as per serial item 21 herein before but for socket outlet 3 pin 6 Amps on independentboard complete all as specified and directed 24 All as per serial item 21 herein before but One socket outlet three pin ,6/16 Amp, independent board, with 2.5 Sqmm (nominal area ) FRLSHcable & 2.5 Sqmm (nominal area ) cable as earth continuity conductor 25 Switch modular type (ISI marked), single pole, one way 6 Amps, one module(ISI marked), complete all as specified & directed. 26 Switch modular type (ISI marked), single pole, one way 16 Amps, one module(ISI marked), complete all as specified & directed. 27 Socket shutters outlet 2/3 pin 6 Amp modular type multi purpose two module (ISI marked), complete all as specified & directed. 28 Socket shutters outlet 2 in 1 pin 6/16 Amp modular type multi purpose combined 2 module (ISI marked), complete all as specified & directed. 29 Ceiling rose, PVC or polycarbonate of size 65mmx50mm three terminals (ISI marked) all as specifiedand directed by Engineer-in-charge. 30 Modular switch type stepped fan regulator, single pole, 230 volt two module complete all as specified and directed. 31 Lamp holder, PVC/Polycarbonate type with back plate modular type fixed on wall suitable for batten fitting ,complete all as specified and directed. 32 LED lamp9 watts, B-22 type complete all as specified . 33 Disconnecting the power supplyand taking down carefully by unscrewing from boards fittings and fixtures such as DBs, Junction Box, Panels of any size complete with all MCCBs ,MCBs etcand removing from site, Complete all as specified and directed . 34 MCCB, 125 Amps, four pole, 3 phase , 36KA, 415 volt with adjustable thermal andmaganetic release, with proper thimble complete all as specified and directed 35 Vertical TPN distribution board double door flush mounting with provisions for MCCBs incomer upto 125 Amps & outgoing 4 way having IP 43 protection Complete all as specified and directed . 36 MCB DB, IP 43 protection, powder coated double door with locking arrangement suitable for surface and flush mounting, 12 way SPN with 200 Amps busbar 240V completed all as specified and directed. 37 MCB DB, IP 43 protection, powder coated double door with locking arrangement suitable for surface and flush mounting, 08 way SPN with 200 Amps busbar 240V completed all as specified and directed. 38 Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole 20 Amp MCB complete all as speicified and directed. 39 MCB, SPN, 240 volt,40 to 63 Amps, 10 KA , C series including connection with suitable size aluminium / copper lugs complete all as specified and directed 40 SPN 32 Amp rating 240V, 10KA C curve miniature circuit breaker (MCB) of single pole and current carrying capacity in the MCB DB complete with connection testing and commissioning compelte all as specified and directed. 41 MCB, SP, 240 volt,40 Amps, 10 KA , B series including connection with suitable size aluminium / copper lugs complete all as specified and directed 42 MCB ,SP, 240 volt, 6 Amps to 32 Amps, 10 KA , C series including connection with suitable size aluminium / copper lugs complete all as specified and directed 43 32 Amp RCBOsfor earth leakage protection, overload & short circuit protection double pole 30mA complete all as specified and directed. 44 Surge protection device AC 2 Pole 20 to 40kA complete all as specified and directed. 45 LED lights fitting 1x 20W, 220V,AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. 46 LED panel recess mounted ultra slim 2x2 - 36 wattsultra slim (cool day) ceiling light, aluminum extruded housing with milky diffuser, heat exchanger unit, LED driver, surge protection complete suitable for perfect lighting cutting hole of required size in POP/false ceiling making good disturbed including taking down any type ceiling fittingcomplee all as specified and directed. 47 Taking down carefully old copper or aluminium sub main wiring of any Nos of wiring and size with earth wire on wooden batten/ surface conduit/ casing- capping complete with its all accessories and making good disturbed surfaces of wall , floors etc complete all as specified and directed. 48 Sub main wiring with two singlecore FRLSH PVC insulated and unsheathed cable with copper conductor of size 4 Sqmm (nominal area), 1100 Volt grade(with approved colour coding as per IS) with and including continuous earth wire of size 4 Sqmm PVC insulated and unsheathed FRLSH multi stranded copper conductor 1100 volts grade , and connected to main board drawing throughPVC concealed conduit 25mm size(minimum size), cutting chases in walls for PVC concealed conduit and making good the disturbed surfacesby providing by wall putty/POP after mason work and finshing to match the original surfaces and nothing extra shall be paid on this account all as specified and directed. 49 Sub main wiring with two singlecore FRLSH PVC insulated and unsheathed cable with copper conductor of size 10 Sqmm (nominal area), 1100 Volt grade(with approved colour coding as per IS) with and including continuous earth wire of size 10 Sqmm PVC insulated and unsheathed FRLSH multi stranded copper conductor 1100 volts grade , and connected to main board drawing throughPVC concealed conduit 25mm size(minimum size), cutting chases in walls for PVC concealed conduit and making good the disturbed surfacesby providing by wall putty/POP after mason work and finshing to match the original surfaces and nothing extra shall be paid on this account all as specified and directed.NOTE FOR SERIAL ITEM NO 34, 35 & 36:(i)Two runs of cable, one run of earth wireshall be considered as one running metre(ii) colour code shall be Red for phase, Black for neutral and green for earth 50 Supply and fixing sub main wiring with Four singlecore FRLSH PVC insulated and unsheathed cable with copper conductor of size 10 Sqmm (nominal area), 1100 Volt grade(with approved colour coding as per IS) with and including continuous earth wire of size 10 Sqmm PVC insulated and unsheathed FRLSH multi stranded copper conductor 1100 volts grade , and connected to main board drawing throughPVC concealed conduit 25mm size(minimum size), cutting chases in walls for PVC concealed conduit and making good the disturbed surfacesby providing by wall putty/POP after mason work and finshing to match the original surfaces and nothing extra shall be paid on this account all as specified and directed.Note : (i)Four runs of cable, one run of earth wireshall be considered as one running metre(ii) colour code shall be Red for phase, Black for neutral and green for earth 51 Cutting chases in brick walls, pinning in, making good to facings where required and pointing in cement mortar (1:3) to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc and cutting chases for concealed water tubing or concealed conduit wiring etc and making good, cutting not exceeding 10cm girth Complete all as specified and directed . 52 25mm dia, rigid non metallic PVC concealed conduit, ISI marked, inclusive of all fittings (such as junction boxes, bends, elbows, tees, reducers, bell mouth tube ends) and all fixing accessories such as couplers lock nuts, saddless, pipe hooks etc for wiring, fixed as in repair Complete all as specified and directed . 53 32mm dia, rigid non metallic PVC concealed conduit, ISI marked, inclusive of all fittings (such as junction boxes, bends, elbows, tees, reducers, bell mouth tube ends) and all fixing accessories such as couplers lock nuts, saddless, pipe hooks etc for wiring, fixed as in repair Complete all as specified and directed . 54 Round shape 12 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size, fixed as in repair complete all as specified and directed. 55 Exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 300mmand provision of flexible copper cable 3 core from ceiling rose to exhaust fan complete all as specified and directed. 56 Wall mounted fan PVC body, 400mm sweep, 230 volt , AC,quick start torque motor with copper winding complete all as specified and directed. 57 Supply Installation, commissioning & testing LT Panel indoor type made out of 3.15mm thick steel and angel iron supports complete factor made plinth mounted, cubical type, dust and vermin proof, front back and sides openable duly provided with bus bar chamber, cables entry chamber, cabinets of suitable size for housing MCCBs metering cabinet for fixing voltmeter, ammeter and indicators lamp and painted with two coats of synthetic enamel paint (Powder coated )over one coat of red oxide primer and using copper bus bar of 250 Amps rating for phase and half of the rating of neutral duly fixed with suitable insulators and nuts and bolts comprising of the following incoming and outgoing feeder control complete all as specified and directed.(A) INCOMING :-(a)MCCB 250 Amps, 4 Pole, 35 KA -01 Nos(b)Voltmeter digital type 0 to 500 volts with selector switch – 01 No(c) Ampere Meter digital type 0 to 100 front operated Amp with selector switch – 01 No(d)Change over switch off load type 4 pole, 250 Amp – 01 No(B)OUTGOING(a)MCCB 200 Amps 4 pole 35 KA- 01 No(b)MCCB TPN, 25 KA, 160 Amp -01 No(c)MCB SPN 40 amp – 01 No 58 Earthing complete with galvanized steel earth plate electrode 60cmx60cmx6.00mm thick, burried directly in ground vertically to a depth not less than 2.25m below normal ground level, with top edge of the plate not less than 1.5m below normal ground level, earth plate surrounded by 15cm thick and packed alternate layers of charcoal dust and common salt, connected with and including earth lead of GI wire 4mm dia (8 SWG) by means of bolts, nuts, check nuts and washers of galvanized iron or thimbles and other end of the earth wire connected to main switch board and protected by galvanized iron pipe light grade 15mm dia bore including watering pipe 20mm dia bore GI light grade (ISI marked) with funnel and wire mesh, including all necessary excavation and earth work, PCC chamber in plain cement concrete (1:3:6) type C-1 and pit cover of presast RCC with MS frame etc and all as shown in electrical plate No 3 of MES Sch Part-I (2009), complete including dismantling of old earthing, all as specified and directed. Note(s) :-(i) RCC pit cover shall be pre-cast of RCC (1:2:4) type B-1, 80mm thick reinforced with XPM not less than 4Kg/Sqm.(ii)PCC chamber shall be constructed 500 mm away from the edge of earth pit.(iii) Rate shall include earth lead and protection pipe of length 7.5m(iv)Earth resistance should be less than 3Ohm. In case the test results are not found below 3Ohm, complete earthing will be redone without any extra cost to Govt.(v) unit rate including protection pipe and GI wire 4.00mm dia from top to earth plate upto 7.5 meter 59 Earthing complete with galvanized steel earth plate electrode 60cmx60cmx6.00mm thick, burried directly in ground vertically to a depth not less than 2.25m below normal ground level, with top edge of the plate not less than 1.5m below normal ground level, earth plate surrounded by 15cm thick and packed alternate layers of charcoal dust and common salt, connected with and including galvanised iron strip 25 x 4mm by means of bolts, nuts, check nuts and washers of galvanized iron or thimbles and other end of the earth wire connected to main switch board and protected by galvanized iron pipe light grade 15mm dia bore including watering pipe 20mm dia bore GI light grade (ISI marked) with funnel and wire mesh, including all necessary excavation and earth work, PCC chamber in plain cement concrete (1:3:6) type C-1 and pit cover of presast RCC with MS frame etc and all as shown in electrical plate No 3 of MES Sch Part-I (2009), complete including dismantling of old earthing, all as specified and directed. Note(s) :-(i) RCC pit cover shall be pre-cast of RCC (1:2:4) type B-1, 80mm thick reinforced with XPM not less than 4Kg/Sqm.(ii)PCC chamber shall be constructed 500 mm away from the edge of earth pit.(iii) Rate shall include earth lead and protection pipe of length 7.5m(iv)Earth resistance should be less than 3Ohm. In case the test results are not found below 3Ohm, complete earthing will be redone without any extra cost to Govt.(v)unit rate including protection pipe and GI strip 32x 6mm from top to earth plate upto 7.5 meter 60 50mm outer dia, double walled corrugated (DWC) HDPE duct pipe pipes of pressure rating 6 kgf/sq. cm conforming to IS 14930 Part-II with anti rodent and non flame propogating properties of approved colour with fittings for cable protection, make as approved by Engineer-in-charge completeall as specified and directed 61 Supply and laying XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 50 sqmm, 3.5 core, laid in trenches , sleeving through pipes of fixed on poles & wall or laid under floors inlcuding jointing with suitable size of alumunium lugs as specified, including taking down old unserviceable cable compelte all as specified and directed. 62 Supplying, installing and commissioning of split type air conditionerwith coolingfunction EER 3.2 of capacity 2TR, 05 star rated with cordless remote control unit and in built air ioniser, plasma filter for better indoor air quality, suitable for wall mounted, single phase, 230/250 volt AC including breaking necessary hole in wall for fixing indoor and outdoor unit and making good to disturbed surfaces with cement mortar to match with existing finishes after commissioning,PVC pipe medium duty 25 mm dia for draining out condensed water,all as required including necessary electric connections, complete all as specified and directed.Note :- (i) Quoted rates shall deem to include the cost ofdrain pipe, copper tubing of requisite length and 4 sqmm multi standard copper cable, brackets, etc.(ii)Installation and commissioning to be done through OEM / itsauthorised service centre / agency. 63 Supply and installed voltage stabilizer automatic digital display type, single phase naturally air cooled indoor type & designed for input variation between 170V to 250 Volt with output voltage stabilized at 230 Volt +/- 2.5% of capacity 5.0 KVA complete all as specified and directed.
Contract Date: Sep 18, 2025 Contract Value : 16.17 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 2
31.
Housing Urban and Rular Development #8019461 AOC
DEPOSIT-Muttil GP-CCTV -Supply and Installation of CCTV (modified) at Public places in Muttil Grama Panchayat, Wayanad-General Electronics Work-CCTV 2 OD100734/2025-2026:Supply and installation of STQC certified 4MP IP IR varifocal Bullet camera with 1/2.7 inch 4MP PS CMOS Image Sensor, Minimum Illumination: 0.001 lux @F1.4 (Color, 30 IRE), 0.0001 lux @F1.4 (B/W, 30 IRE), 0 lux (IR on), Auto/Manual 1/3 s-1/100000 s Shutter Speed, 2.7-13.5 mm Lens, IR Range of 60 m, H.265, H.264+, H.264, H.264H, H.264B, MJPEG (Only supported by sub stream), Quad Stream, Video Compression, 4MP (2688 x 1520) @1-25/30fps, 4MP (2560 x 1440) @1-25/30fps, up to CIF Resolution,Audio compression: G.711a, G.711Mu, G.726, Built-in Mic, Protocol: SFTP, IPv6, IPv4, DNS, RTCP, NTP, RTP, HTTP, HTTPS, SNMP V1/ V2/ V3, TCP/IP, PPPoE, NFS,UDP, ICMP, SSL, DHCP, SMTP, RTSPS, ONVIF (Profile S, G, T), unicast, multicast. AES 256-bit Encryption, Configuration encryption, trusted execution, Digest, security logs, WSSE, account lockout, syslog, video encryption, IP/MAC filtering, HTTPS, trusted upgrade, trusted boot, IP67 and IK10, Basic: 2 W (12 VDC); 2.6 W (PoE) Max. (H.265+ intelligence on + WDR + illuminator on): 6.1 W (12 VDC); 7.2 W (PoE) Power Consumption, etc. Preferred make: CP PLUS or equivalent 3 OD100784/2025-2026:Supply and installation of 16CH NVR with Max. 384 Mbps incoming/ recording/ outgoing bandwidth, H.265/ Smart H.264+/ H.264/ MJPEG codec decoding, AI by Recorder: 2-channel face detection or recognition/ 4-channel perimeter protection/ 8-channel SMD Plus, Support 2 SATA HDDs (minimum 10TB Each), 1 x 10/100/1000 Mbps Ethernet port, 2 x USB Ports (1 USB 3.0), HDMI/VGA simultaneous video output, 32 MP; 24 MP up to QCIF, etc. Preferred Make: CP-PLUS or equivalent 4 OD58249/2025-2026:Supply and installation of wireless mouse for NVR. Preferred Make: Dell, HP, Lenovo, Logitech 5 OD120712/2025-2026:Supply and installation of 6TB HDD. Preferred Make: Seagate, WD, Toshiba 6 OD122776/2025-2026: Supply and installation of 32 inchSmart LED Display with 16:9 aspect ratio, 2 x HDMI inputs, USB, etc. supplied with all necessary accessories including wall mounting kit and HDMI cable. Preferred Make: LG 32SR50F-W, Panasonic, Samsung, Sony or equivalent 7 OD100815/2025-2026:Supply and installation of L2 managed gigabit Ethernet switch with 8 x 10/100/1000 BASE-T PoE ports, 2 x SFP ports, 65 W PoE budget, 20 Gbps Switch Capacity, etc. supplied with all necessary accessories. Preferred Make: D-Link or equivalent 8 OD58247/2025-2026:Supply and installation of Mild Steel/GI Round pole for fixing CCTV cameras with 100 mm diameter, 3.6 mm thickness, 4mheight, suitable size base plate and fixing bolts, etc. supplied with all necessary accessories 9 11.1.1:Erection of RCC/ PCC pole of following length in brick ballast and ramming the foundation, finishing with 150mm thick cement concrete (1:3:6) layer on top with including excavation and refilling etc as required.Above 4.5 metre and upto 6.5 metre 10 OD58264/2025-2026:Supply and installation of outdoor weatherproof and water proof Heavy Duty CCTV Camera Housing for outdoor camera 11 OD58261/2025-2026:Supply and installation of Galvanized Steel Folded 19 inch 6UIP56/66 outdoor rack with DIN Std. 10 mm Sq. Slots, Pure Polyester Powder Coating, Conforms to DIN 41494 and IEC 60529 Equivalent Standards, etc. supplied with all necessary accessories including PDU andpole mounting kit. 12 2.13.1:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps 13 2.14.1:Supplying and fixing following rating, double pole, (single phase and neutral),240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 25 amps 14 OD58253/2025-2026:Supply and installation of Weather proof 250 mm x 200 mm x 105 mm SMC Meter Box with Concealed metal hinges, Mounting screws, etc. supplied with all necessary accessories including pole mounting kit. Preferred make: Sintex GSMB-2520 or equivalent 15 90.16.1.10:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.25 mm GI conductor (10 SWG) 16 OD58258/2025-2026: Supply and providing ISI pipe earthing as per IS 3043 CI/GI earth pipe with required filling charcoal around the earth pipe up to a distance of 15 cm, filling the rest of the portion with excavated soil, including watering and ramming, providing brick work (20 mm) necessary at the top in 1:6 cement mortar providing cast iron gully trap with GI covering at the top 17 OD58250/2025-2026:Supply and fixing of UL certified 19 inch 9U Rack with Front Glass door and lock and all mounting hardware including Horizontal Cable organizer suitable for 19 inch Rack, 2U standard, 230V 6A Inlet Plug type Indian Round Pin 6 Nos, Power Distribution Unit, 8A Fuse, ,Air circulation module 90CFM. Preferred Make: D-Link, Netrack, Valrack 18 OD58246/2025-2026:Providing GPON connection at each pole with suitable ONT and fiber termination box etc. as required including installation connection and service charges for one year 19 OD58256/2025-2026:Supply, installation, testing, and commissioning of UL Listed, ETL verified 0.5 meter CAT 6 UTP Patch Cord having LSZH jacket, 24 AWG bare copper conductor UTP 4 pair both end factory Crimped with modular male plugs with minimum 500 insertion cycles terminiated as per TIA/EIA 568-B colour code conforming to the standards ANSI/TIA-568.2 , ISO/IEC 11801, IEEE 802.3, ISO/IEC 60332-1,and RoHS Complaint. Preferred Make: Molex, Honeywell, Commscope, Norden 20 OD58255/2025-2026:Supply and installation of 1 KVA offline UPS with 2 x 7 Ah Battery. Preferred Make: Hykon, Numeric 21 OD58263/2025-2026:Supply, installation, testing, and commissioning of UL Listed, ETL verified 2 meter CAT 6 UTP Patch Cord having LSZH jacket, 24 AWG bare copper conductor UTP 4 pair both end factory Crimped with modular male plugs with minimum 500 insertion cycles terminiated as per TIA/EIA 568-B colour code conforming to the standards ANSI/TIA-568.2 , ISO/IEC 11801, IEEE 802.3, ISO/IEC 60332-1,and RoHS Complaint .Preferred Make: Molex,Honeywell, Commscope,Norden 22 OD58252/2025-2026:Supply, drawing. testing and commissioning of UL certified and ETL verified 23 AWG bare copper conductor UTP 4 pair unarmoured Out Door Anti-Rodent, anti-termite CAT 6A cable with HDPE Insulation Material and LSZH Outer Jacket conforming to the standards ANSI/TIA-568-C.2, ISO/IEC 11801, IEEE 802.3, ISO/IEC 60332-1, ISO/IEC 61034-2,ISO/IEC 61754-2, IEC 61156-5, Colour Code Per TIA/EIA 568-B,RoHS Compliant transmission performance tested upto 500 MHz or better and Insertion Loss/ Attenuation: 50 dB/100m or better at 500 MHz in the existing conduit as required 23 1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm 24 OD126741/2025-2026:Splicing charges including necessary equipment and labour for obtaining error- free fiber joints and splicing box as required for the project.
Contract Date: Sep 16, 2025 Contract Value : 7.11 Lakh
Government Departments No of Bidders 2
32.
Housing Urban and Rular Development #7948353 AOC
Special Repair Of Landscaping Work At Haryana Bhawan New Delhi. (New Automation Irrigation System) , Supply,Hdpe Pipes Is 4984 :2016 And Compression Push Fit Type Fittings Including Make Godavari, Finolex , Duraline, Jain. Supply,Fixing & Commissioning Of Hdpe Pipe Isi 63Mm Od-Pe 100 Pn 6 (N.S). , Supply,Fixing & Commissioning Of Hdpe Pipe Isi 50Mm Od- Pe 100 Pn 6 (N.S). , Supply,Fixing & Commissioning Of Astm Upvc Pipe 1.5 Sch-40 Make Ashirvad /Astral (N.S). , Supply,Fixing & Commissioning Of Astm Upvc Pipe 3/4 Sch-40 Make Ashirvad /Astral (N.S). , Supply,Fixing & Commissioning Of Pop Up Spray Heads 1/2 Inlet And Radius Ranging From 3-5 M With Interchangeable Nozzles And All Accessories Complete As Per Bis Standards And Setting Flow Rate As Directed With Pop Up Having Moulded Wiper Seal Moulded Into Cap. Make: Rain Bird / K-Rain/ Nelson(Hsr :- 26.71.3). , Supply, Fixing & Commissioning Of Lope Emitting Pipe 16 Mm; Class 2 (0.3 M X 1 To 4 Lph),Anti-Rodent, Complete With All Accessories As Per Bis Standard Specifications Make:Rainbird / Metzer / Eurodrip / Godavari. (Hsr 26.69.4) , Supply,Fixing & Commissioning Of Pvc Ballvalves 1 - Make Astore/Ashirwad/Gf (N.S). , Supply,Fixing & Commissioning Ofpvc Ballvalves 1.5 - Make Astore/Ashirwad/Gf (N.S). , Supply,Fixing & Commissioning Of 12 Rectangular Valve Box With Cover Make: Rain Bird /Dwc / Cepex (N.S). , Supply,Fixing & Commissioning Of 1.5 Solenoid Globevalves With Fabric Reinforced Diaphramand Rugged Pvc Construction,Compatible And Slow Closing To Prevent Water Hammer,Pressure Rating Upto 10.4Bar And,Max Water Temp. Upto 42Degree Centigrade, With 24Ac Solenoid,Current Rating 0.41A @60Hz,Coil Resistance 30Ohm With Provision To Attachprs-Dial Make: Rain Bird / Bermad / Toro (N.S). , Supply,Fixing & Commissioning Of 1 Solenoid Globevalves With Fabric Reinforced Diaphram And Rugged Pvc Construction,Compatible And Slow Closing To Prevent Water Hammer,Pressure Rating Upto 10.4Bar And Max Water Temp. Upto 42Degree Centigrade, With 24Ac Solenoid,Current Rating 0.41A @60Hz,Coil Resistance 30Ohm With Provision To Attachprs-Dial Make: Rain Bird / Bermad / Toro (N.S). , Supply,Fixing & Commissioning Of, Installing And Commissioning Of Direct Burial Connector For Cable Joint Make: Paige / 3M / Rain Bird (N.S). , Supply,Fixing & Commissioning Of 18 Awg Cablewith High Molecular Weight Polyethelene And Applications Upto 600Volts , Temperature Upto -55 To+ 60 Deg Centigrade ,Soft Drawnbarecoppermeetingastm B3, Tensile Strenth 1400Psi For Two Way Communication Betwee Nsolenoid Valvel And Controller Make: Rain Bird / Paige (N.S). , Supply,Fixing & Commissioning Ofcondiut Pipe For Cable Ducting 25Mm Make Polypack Or Equivalent (N.S). , Supply,Fixing & Commissioning Of6 Station Module For Automation Controller Make- Rainbird (N.S). , Excavating Trenches Of Required Width For Pipes, Cables, Etc Including Excavation For Sockets, And Dressing Of Sides, Ramming Of Bottoms, Depth Up To 1.5 M, Including Getting Out The Excavated Soil, And Then Returning The Soil As Required, In Layers Not Exceeding 20 Cm In Depth, Including Consolidating Each Deposited Layer By Ramming, Watering, Etc. And Disposing Of Surplus Excavated Soil As Directed, Within A Lead Of 50 M (Hsr 4.16) Pipes, Cables Etc, Not Exceeding 80 Metre Mm Dia (Hsr 4.16.1.1). , Demolishing Cement Concrete Manually/ By Mechanical Means Including Disposal Of Material Within 50 Metres Lead As Per Direction Of Engineer - In - Charge. (Hsr 5.23) Nominal Concrete 1 :2:4 Or Leaner Mix (I/C Equivalent Cum Design Mix) (Hsr 5.23.2).
Contract Date: Sep 15, 2025 Contract Value : 5.66 Lakh
Government Departments No of Bidders 3
33.
Housing Urban and Rular Development #7928535 AOC
tender for Upgradation Of Different Electrical Installation Work In Different Govt. And Hospital Buildings Under Katwa Electrical Sub-Division, Pwd As And When Required In Fy25-26. Emergent Nature Ei Work Within Katwa. - 1 Dismantling the existing electrical installation as per requirement by Cos own tools, tackles & manpower maintaining normalcy as far as possible and depositing the dismantalled damaged materials to the Sectional Store of PWD and mending good the damages upto the satisfaction of Authority / PWD by deputed oneElectrician and one helper for ½days. 2 Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, on wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment (2+8 Way) [D9/13](Make: LEGRAND/SIEMENS/CRABTREE/ SCHNIDER/ABB) 3 Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection [D-6/7](Make: Legrand/ Schneider/ Siemens/Crabtree/ABB) SP(6-32A) For Outgoing 4 TP(63A) For Outgoing 5 Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection. (D-5/6), (Make:Legrand/Schneider/Siemens/Crabtree/ABB)DP(40A) For Incoming 6 Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded FR PVC insulated & unsheathed copper wire (approved make) partly in 20mm size PVC rigid conduit FR (Make:-Polycab/ Havells/RR Kabel/Gloster) [for horizontal run & above false ceiling portion only] and in 19mm bore, 3mm thick polythene pipe [for vertical run embedded in wall], with 1x22/0.3 (1.5 sqmm) single core stranded FR PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Piano Key type switch fixed on MS CRC sheet metal (16 SWG) switch board on wall complete with 2 no. “Ph & N” copper bar incl. bakelite/ Perspex top cover 3 mm thick and incl. 175x100x65mm inspection box, making earthing attachment, painting the MS box and mending good the damages to original finish [PVC Rigid Conduit only for horizontal run & above false ceiling and vertical run concealed] -- 2x22/0.3 (Ph. & N) and 1x22/0.3 as ECC [E-16/6]Average run 8 mtr 7 Average run 10 mtr 8 Distribution wiring in 1.1 KV grade 22/0.3 (1.5 sqmm) single core stranded FR PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit FR (Precision make), with 1.1 KV grade 1 x 22/0.3 (1.5 sqmm) single core stranded FR PVC insulated & unsheathed copper wire as ECC, to 5A 3 pin flush type plug socket & Piano Key type switch fixed on MS CRC sheet metal (16 SWG) switch board cum JB on wall incl. bakelite/Perspex (wall matching color) top cover 3 mm thick and incl. painting the MS box and mending good the damages to original finish -- 2x22/0.3 (Ph. & N) and 1x22/0.3 as ECC [E-15/4]On Board 9 Supply & Fixing 240 V, 20A, plug socket with separate 20 A Piano key type switch (Anchor) on sheet metal switch board embedded in wall incl. S & F 150x100x65mm MS (16SWG) switch board (Box should be CRC punch type and RO Primer Coated Painted) and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required.[E-6/22] 10 Supply & Fixing 240 V, 2 nos. 6A Socket with separate 2 nos. 6 A Piano key type switch (Mk. Anchor) on sheet metal switch board embedded in wall incl. S & F 175 x 100 x 65mm MS (16SWG) switch board with Ph, N, E Bar and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required. [E3/10,E5/14 & 15] 11 Supply & Fixing 240 V, 3 nos. 6A, & 1 no. 20A plug socket with separate 3 nos. 6 A & 1 no. 20A Piano key type switch, indicator & 20A switch type SP MCB (Mk. Anchor) on sheet metal switch board embedded in wall incl. S & F 40x200x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required. (E7/26) 12 Supply & Fixing 240 V, 20 A Piano key type Socket (Mk.Anchor) on sheet metal switch board incl. S & F 100x100x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required. (E6/17b) 13 Supply & Fixing 240 V, 25 A, Modular type starter (Mk. Anchor Roma / Legrand Myrius / North West) with 25A Modular switch type DP MCB (C Curve) and 4 Module GI Modular type switch board with 4 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. (E19/17) 14 Supply & Fixing 240 V,25 A, 3 pin Moduler plug top with indicator (Make:-Anchor roma/Legrand/ Cabtree) & necy. Connections. E-17/5.b 15 Supply and delivery of Single LED Fitting (Roboust Industrial Type suitable for surface, wall & conduit mounting, 22SWG Powder Coated, Screwed Down Cover) with all accessories and 1 no. PC Body LED Tube (1 X 20/18Watt, 230VAC, 50hZ, 2100 Lm, Colour Temp. 6500K, THD<10%, bult in 2.5KV SPD) (Mk, Philips, Fitting Cat No. TMC 502P 1xT-LED 22W P3242, Lamp Cat No. Mas LED Tube 18W 2100 Lm 865 T8 (VE) / eqv. CGL / Jaquar ) 16 Supply and delivery of Double LED Fitting (Roboust Industrial Type suitable for surface, wall & conduit mounting, 22SWG Powder Coated, Screwed Down Cover) with all accessories and 2 no. PC Body LED Tube (2 X 20/18Watt, 230VAC, 50hZ, 2100 Lm, Colour Temp. 6500K, THD<10%, bult in 2.5KV SPD) (Mk, Philips, Fitting Cat No. TMC 502P 1xT-LED 22W P3242, Lamp Cat No. Mas LED Tube 18W 2100 Lm 865 T8 (VE) / eqv. CGL / Jaquar ) 17 Fixing only single/twin fluorescent light fitting complete with all accessories directly on wall/ceiling with supplied clamps with LED tube lights on HW block or plates, nipples etc. as required as per direction of the EIC. (C2/14c) 18 Fixing only single/twin fluorescent light fitting suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports fixed with “L” type MS clamp whose one side fixed on ceiling with sutable size 4 nos. fastener and other side connected with the conduit with suitable size of bolts and nuts incl. S&F EI conduit, “L” type (125mmx125mm) 6mm thick and 25mm with MS clamps and connecting the length of PVC insulated wire and mending good damages to original finish and painting etc. by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length.[C-2/17] 19 Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc. incl. S&F connecting wire for down rod upto 30 cm incl. painting the rod with approved paint and making necessary connection as required by 2x1.5 sqmm flexible copper wire.[C-3/21a] 20 Supply & Fixing Socket type fan regulator (Step type) (Mk.Anchor) on existing sheet metal switch board with bakelite/perspex top cover by screw after making housing for regulator knob by cutting bakelite/perspex top cover incl. making necy. connections etc. (E6/18) 21 Supplying & Fixing MS fan clam of two piece type for RC ceiling as per approved specification, fabricated from 40 mm x 9 mm MS flatincluding making good damages to building roof with satisfactory finishing and painting – (As per Drawing no. 475 of PWD Specification Book – May 1991)[D-14/29] 22 Supplying and fixing PVC Rigid Conduit FR [Precision MMS Make] on wall, ceiling with saddles and other accessories as required and mending good damages to building works (E16/7)20 mm Size 23 25 mm Size 24 Supplying and Drawing 1.1 KV single core stranded FR PVC insulated & unsheathed single core stranded copper wire of the following sizes in the prelaid polythene pipe / casing and by the prelaid GI fish wire and making necy. connection as required (Mk. RR Kable, Havells/Polycab/Gloster).E-92x84/0.3 (6 sqmm) + 1x56/0.3 (4 sqmm) as ECC 25 2x36/0.3 (2.5 sqmm) + 1x22/0.3 (1.5 sqmm) as ECC 26 2x56/0.3 (4 sqmm) + 1x36/0.3 (2.5 sqmm) as ECC 27 2x22/0.3 (1.5 sqmm) + 1x22/0.3 (1.5 sqmm) as ECC 28 Finishing of the PVC insulatedCopper wire ends by socketting with pin/ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. (F-5/9)6 sqmm 29 4 sqmm 30 S&F AC / Street light Timer DB (Water Proof) concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment and febricated with following items as per instructions ofEIC i) 240V, 6-32 A SPMCB of breaking capacity 10KA & C Charecteristic-01 noii) 240V 6-32 A DP MCB Isolator on din rail- 01 No.iii) 240V , 2Pole Power Contractor (rating above 20 Amp) with accessories- 01 noiv) Astronomical / Digital timer switch-01nov) Toggle switch for manual/auto operation- 01no. vi)Double door 2+8 Way SPNDB- 01Novii)Necessary connection by 1.5/2.5/4sq.mm copper wire.[Make : Siemens/ Legrand/ L&T] 31 Earthingwith50mmdiaGI pipe 3.64mm thick x3.04Mts. long and 1x4 SWGGI(HotDip) wire (4Mts. long),13mm dia x80mm long GI bolts,double nuts,double washers incl. S& F15mmdiaGIpipeprotection(1Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65Mts. below the ground level as below: By ISI-Medium GI pipe [G-1/2a] 32 Excavation of soil for installation of Earth Electrode and filling & ramming For Soft Soil [G-1/1a] 33 Supplying & fixing earth busbar of galvanized(HotDip) MSflat 25mmx6mm on wall having clearance of 6mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required.[G-2/4a] 34 Connecting the equipments to earth busbar including S&F GI (HotDip) wire of size as below on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages Solid GI wire No. 8 SWG [G-2/5] 35 Supply & Delivery 1.1 KV grade LT Aluminium PVC/XLPE Armoured cable ( Make-Polycab /RR Kabel/Havells/Gloster) as per direction of EIC. The cable shall conform to IS 7098/ Part I with anti termite and anti rodent features.2.0 Core 10 sq.mm. 36 4.0 Core 16 sq.mm. 37 4.0 core 35 sq.mm 38 4.0 core 95 sq.mm 39 Laying of cable upto 3/4 core 25 sqmm on wall/surface incl. S & FMS saddles with earthing attachment in 10 SWG GI (Hot Dip)Wire, making holes etc. as necy. mending good damages and painting--F-1/2.b 40 Laying of cable from 3/3½ core 35 sqmm to 50 sqmm onwall/surface incl. S & F MS saddles with earthing attachment in 2x 10 SWG GI (Hot Dip) Wire, making holes etc. as necy., mendinggood damages and painting---F-1/2.c 41 Laying of cable above 3½ core 50 sqmm and upto 3½ core 90sqmm on wall/surface including S & F MS clams with earthingattachment in 2 x 10 SWG GI (Hot Dip) Wire, making hole etc. asnecy., mending good damages and painting...F-1/2.d 42 Laying of one No. cable above 35 sqmm and upto 185 sgmm in underground trench 460mm wide x 76Omm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per Mtr. including filling the space between the bricks and cable and also the trenchwith shifted soil, leveling up and restoring surface duly rammed.---F-2/1.a 43 Straigh through Jointing of cable of different size by compound jointing kit including S&F ferrul, tapes and jointing materials (Jointing Kit Mk. Recam)---F-6/10i) 3½/ 4 core 25-35 sqmm cable 44 i) 3½/ 4 core 16-25 sqmm cable 45 i) 3½/ 4 core 95 sqmm cable 46 Supplying and fixing compression type gland complete with brass gland, |brass ring & rubber ring for dust & moisture-proof entry (Mk. Dowels) of XLPE/PVC armoured cables as below:---F-4/7.ci) 4 Core 16 sq.mm. 47 ii) 4 core 35 sq.mm 48 iii) 4 core 70 Sq.mm 49 iv) 4 Core 95 Sq.mm 50 Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make). |tapes, anticorrosive paste & jointing materials. --F-5/8.bi) 4 Core 16 sq.mm. 51 i) 4core 35 sq.mm 52 iii)4core 70 sq.mm 53 iv) 4 core 95 Sq.mm 54 Supplying & fixing medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing metarials as required. (F6/11) (For fixing over wal on building. pipe must be provided with necessary MS Clamp)---F-6/11a. 65 mm dia 55 b. 50 mm dia 56 c.40 mm dia 57 Supply & delivery of 9W led lamp. Make- Philips/Wipro/Crompton 58 Supply & delivery of 2.5 mfd fan capacitor( Make-Tibcon/Universal) 59 Analog timer switch- 01no (L&T) 60 S&D of 230 V. 9 dia Heavy duty exhaust fan with blades & others accessories. (E.P.C. / Orient/ Crompton make as per direction) 61 S&D of 230 V. 12 dia Heavy duty exhaust fan with blades & others accessories. (E.P.C. / Orient/ Crompton make as per direction) 62 Supplying & Fixing GI Modular Switch Board of the following sizes complete with three no. suitable size Copper bar with holes (for Ph, N & E) fixed on bakelite/Hard Rubber insulator over the MS welded chairs incl. top cover flushed in wall for housing the board after cutting the brick wall incl. makingearthing attachment, painting and mending good damages to building works6 Module 63 8 Module 64 Rates to be quoted will be inclusive of all the taxes incl. GST.No other additional charges will be applicable in addition to the quoted rates.
Contract Date: Sep 10, 2025 Contract Value : 3.40 Lakh
Government Departments No of Bidders 4
West Bengal View Result →
34.
Housing Urban and Rular Development #7710578 AOC
DEPOSIT-Govt.Law College-Supply and Installation of CCTV at Govt.Law College ,Kozhikode-General Electronics Work- 1 CCTV 2 OD2842/2025-2026:Supply and installation of 64 CH NVR Supported Compression Technique: H.264,H.265, Recording Speed for all channels (fps):upto 50, Maximum Recording Resolution supported: 4K (3840 × 2160)Smart Codec support, 4HDD bays with maximum 18TB each-Internal Storage Expandable upto (TB):80, Redundancy Option: RAID 0,RAID 1,RAID 5,RAID 6,RAID 10, Internal Hard Drive Interface: SATA II,ONVIF Profile S, 10/100/1000 Mbps Ethernet (RJ-45):2, Number of USB Ports:3, Number of PoE Ports:2 , 4 HDMI Ports,Audio Two-way Communication,Live Play Back-Storage and Play back of the connected camera at up to 12MP resolution,Alarm Input/Out:16in/1out. UL LISTED TO UL/CSA 62368-1,CE(EN 62368-1), Comply with UKCA and RCM, RoHS, etc. supplied with all necessary accessories.Preferred Make: Honeywell I-HPNVR-464 or equivalent. 3 OD1551/2025-2026:Supply and installation of 4MP Fixeddome camera with Smart IR, IR Range: Up to 30M , Up to 2560x1440@30fps , Built-In Mic , H.265+/H.265/H.264 , Image Sensor 1/2.7” CMOS , Signal System PAL/NTSC , Min. Illumination Color: 0.002Lux@ (F2.0, ACG ON), B/W: 0Lux with IR , Shutter Time : 1s to 1/100,000s , Day & Night Dual IR Cut Filter with Auto Switch , Lens Type Fixed , Focus 2.8mm , Protection : IP66&IP67, Lightning protection, surge protection , Power Consumption MAX: 6W (12V) MAX: 8W (PoE) , Operating Conditions -30OC ~ 60OC, 0 ~ 95% RH , Power Supply : DC 12V±25%, PoE (802.3af), etc. supplied with all necessary accessories. Preferred Make: Honeywell I-HIE4PI-EL or equivalent. 4 OD1550/2025-2026:Supply, installation and commissioning of 4MP IP Bullet camera resolution Up to 2560x1440@30fps; H.265+/ H.265/H.264 ;Lens 4mm;Image Sensor1/2.8 inch CMOS; Min. illumination Color: [email protected]; Smart IR, IR Range: Up to 50M; Built-In Mic; Video Frame Rate:32Kbps~6Mbps,Max. Image Resolution:1920 x 1080,Support tripwire and perimeter ; WDR 100dB; Surge and Lighting Protection; Smart Defog; Operating Conditions -30°~60°, 0~95% RH;POE, IP67. Preferred Make: Honeywell I-HIB4PI-EL or equivalent 5 OD196963/2024-2025:Supply and installation of 8TB HDD. Preferred Make: Seagate, WD, Toshiba 6 OD196958/2024-2025:Supply and installation of 43 inch Television suitable for working 24x7,LED backlight LCD screen, Wi-Fi, Bluetooth, HDMI inputs, etc. supplied with all necessary accessories including wall mounting kit and HDMI cable. Preferred Make: LG, Panasonic, Samsung, Sony 7 OD4471/2025-2026:Supply and installation of 10m HDMI cable supporting Full HD resolution, with suitable connectors on both end as required, data rate 10 Gbps or better 8 OD197162/2024-2025:Supply and Installation of wireless mouse 9 OD823/2025-2026:Supply and installation ofBIS/CE certified Line Interactive UPS with Load Capacity of 660Watts / 1100VA, Automatic Voltage Regulator (AVR) with Wide Input Voltage Range 145-290V,2x7.2AhCold Start Function, Off-mode battery charging with high voltage protection, Output Voltage: 230V AC±10%, 50 Hz±1%, Backup time : 15-20 minutes at battery full charge condition including all necessary accessories 10 Networking 11 OD2843/2025-2026:Supply and installation of 26-Port Gigabit Ethernet Smart Managed Pro PoE Switch with 24 x PoE+ @ 380W, 2 x 1G SFP, Desktop/Rack mountable switch. Data Link Protocol: IEEE 802.3, Ethernet, SNMP, Gigabit Ethernet. remote/cloud manageable and provides a total PoE budget of 380W for wireless networks IP surveillance and video-over-IP deployments. Preffered Make:GS724TPP or equivalent 12 OD258989/2024-2025:Supply, install and commissioning of 8 port L2 smart managed gigabit switch with 8 x 10/100/1000BASE-T ports, 2 SFP ports,etc. supplied with all necessary accessories.Prefered make: DGS-1210-10 13 OD314901/2024-2025:Supply and installation of 10-Port Gigabit Smart Managed PoE Switch with 8 x 10/100/1000BASE-T PoE ports , 2 x Gigabit SFP ports and 65W PoE budget ,20 Gbps switching capacity,14.88 Mpps forwarding capacity. Preferred Make: D Link- DGS-1210-10P Prefered Make:DLink-DGS-1210P 14 OD188254/2024-2025:Supply and installation of UL listed, ETL verified 1U , 24 port Rack mountable Enhanced Modular type unloaded Patch Panel with rear cable organizer made of cold rolled steel, powder coated, front labelling Facility and suitable for RJ 45 CAT 6/CAT6A Keystones and labelling as required. Preferred make: Molex, Honeywell, Commscope,Norden 15 OD188258/2024-2025:Supply, termination, testing, and commissioning of UL Listed, ETL verified CAT 6 Keystone Jack with dust protection, suitable for 22- 24 AWG bare copper conductor,Minimum 500 insertion cycles and 100 reterminations, as per TIA/EIA 568-B colour code conforming to the standards ANSI/TIA-568.2-D , ISO/IEC 11801, IEEE 802.3, ISO/IEC 60332-1,and RoHS Complaint. Preferred make: Molex, Honeywell, Commscope Norden. 16 OD188640/2024-2025:Supply, installation, testing, and commissioning of UL Listed, ETL verified 0.5 meter CAT 6 UTP Patch Cord having LSZH jacket, 24 AWG bare copper conductor UTP 4 pair both end factory Crimped with modular male plugs with minimum 500 insertion cycles terminiated as per TIA/EIA 568-B colour code conforming to the standards ANSI/TIA-568.2 , ISO/IEC 11801, IEEE 802.3, ISO/IEC 60332-1,and RoHS Complaint. Preferred Make: Molex, Honeywell, Commscope, Norden 17 OD258985/2024-2025:Supply, installation, testing and commissioning of Unloaded 1U Rack mountable LIU Supporting 24SC/48LC with splice tray, cable manager and with sufficient blanking plug to cover unused slots.Preferred Make: Commscope, Honeywell, Legrand, Molex. 18 OD188636/2024-2025:Supply, installation, testing and commissioning of 1m Duplex UPC/APC SC/LC Fiber pig tail confirming to LS0H IEC 61034-1 & 2, IEC-60332-1, IEC60754-1 & 2, ISO/IEC 11801-1:2017, ANSI/TIA/ EIA 568.3-D,ANSI/TIA/EIA-492 standards for terminating fiber in LIU/SFP module. Preferred Make: Commscope, Honeywell, Legrand, Molex 19 OD188639/2024-2025:Supply, installation, testing and commissioning of duplex UPC/APC SC/LC Flange Mount connector with insertion loss 0.02dB or better, RoHS compliant and suitable for existing LIU.Preferred Make: Commscope, Honeywell, Legrand, Molex 20 OD188646/2024-2025:Supply and installation of SFP transceiver module suitable for above switch. Preferred make: D-Link DEM-310GT or equivalent 21 OD188638/2024-2025:Supply, installation, testing and commissioning of 1m Duplex UPC/APC UPC/APC SC/LC Fiber patch cord confirming to LS0H, IEC 61034-1 & 2, IEC-60332-1, IEC60754-1 & 2, ISO/IEC 11801-1:2017, ANSI/TIA/ EIA 568.3-D,ANSI/TIA/EIA-492, RoHS standards and suitable for existing SFP module. Preferred Make: Commscope, Honeywell, Legrand, Molex 22 OD189377/2024-2025:Supply and fixing of UL certified 19 inch 12U Rack with Front Glass door and lock and all mounting hardware including Horizontal Cable organizer suitable for 19 inch Rack,2U standard ,230V 6A Inlet Plug type Indian Round Pin 6 Nos , Power Distribution Unit ,8A Fuse, ,Air circulation module 90CFM. Preferred Make: D-Link or Netrack or Valrack or equivalent. 23 OD188644/2024-2025:Supply and fixing of UL certified 19 inch 9U Rack with Front Glass door and lock and all mounting hardware including Horizontal Cable organizer suitable for 19 inch Rack,2U standard ,230V 6A Inlet Plug type Indian Round Pin 6 Nos , Power Distribution Unit ,8A Fuse, ,Air circulation module 90CFM. Preferred Make: D-Link or Netrack or Valrack or equivalent. 24 OD188645/2024-2025:Supply and fixing of UL certified 19 inch 6U Rack with Front Glass door and lockand all mounting hardware including Horizontal Cable organizer suitable for 19 inchRack, 2U standard, 230V 6A Inlet Plug type Indian Round Pin 6 Nos, PowerDistribution Unit, 8A Fuse, Air circulation module 90CFM. Preferred Make: D link ,Netrack, Valrack or equivalent 25 Cabling 26 OD188647/2024-2025:Supply, drawing. testing and commissioning of UL certified and ETL verified 23 AWG bare copper conductor UTP 4 pair Unarmoured CAT 6 cable with HDPE Insulation Material and LSZH Outer Jacket, conforming to thestandards ANSI/TIA-568.2-D, ISO/IEC 11801, IEEE 802.3, ISO/IEC 60332-1,ISO/IEC 61034-2,ISO/IEC 61754-2,Colour Code as per TIA/EIA 568-B, RoHS Compliant,transmission performance tested upto 500 MHz or better and Insertion Loss/ Attenuation: 33 dB/100m or better at 250 MHzin the existing conduit as required 27 1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm 28 1.21.2:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm 29 OD188649/2024-2025:Supply, laying, and commissioning of 6 Core Optical Fiber Cable OS2 9/125μm, Optical fibres in water blocked loose tube corrugated steel tape armoured (STA) Anti-Rodent, Anti-termite, UV Resistant and conforming to the standards, ISO/IEC 11801, Minimum Crush Resistance 2000N/10 CM, RoHS. Preferred Make: Commscope, Honeywell, Molex 30 14.1:Excavation for foundation in soft soil including dressing of sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 metres. 31 14.15.1:Supplying and laying of following size owe HOPE pipe .lSI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required.63 mm· dia (OD-63 mm & ID-51 mm nominal)
Contract Date: Aug 07, 2025 Contract Value : 11.84 Lakh
Government Departments No of Bidders 7
35.
Housing Urban and Rular Development #7611452 AOC
Integrated Facility Management Services at New Town Business Club & The Club Banquet (Gr. Floor of Pride Hotel) at Action Area – I, New Town, Kolkata (for02 years)- Facility Manager for heading the entire facility team of Office as Single point of contact & overall in charge of FM On- site Operations. 2 Helper of Technician Service (Plumber) Semi skilled 3 Fireman with sufficient Experience (Skilled) 4 Cleaner/ Sweeper (Housekeeping staff) 5 Assistant ( Supervisor Housekeeping) 6 Helper (Ball Boy for Tennis Court) 7 Utility Workers /Attendants for Gymnasium, change room, games room, guest room, office etc. (unskilled) 8 Assistant Supervisor (Security Supervisor for supervision of premises safety & Security works (Semi skilled). 9 SecurityGuards (unskilled) 10 Associated Services 11 Supplying high quality housekeeping cleaning agents / Toiletries / chemicals & appropriate tools/equipment’s to maintain highest level of hygiene & sanitation by killing micro organisms & reducing the organism load on toilet / wash area floors and for removal of organic material & suspended grease or oil from other surfaces as per list furnished in the tender doc & direction of EIC. 12 Integrated Pest Control Services like Spraying for adult mosquito on wall of ground floor and basement, Fogging / ULV spraying at ground floor and basement in the eveningagainst adult mosquito, Indoor residual treatment with spray against cockroach etc.and treatment against cockroach, Rodent baiting at ground floor, basement and lobby as required, Anti larval spraying. (Including Services Required As & When - Rodent Control & Anti Larva Treatment).Twice every month. 13 Garbage Disposal on daily basis from all the floors to centralized waste storage area including canteen, auditorium, external area to the designated place for collection by the authority. The garbage bins are to be disinfected every alternate day. 14 Facade Cleaningincluding providing all basic accessories, equipment needed for personal safety of the cleaner and to carry out the facade cleaning. All equipments will be arranged by the agencylike cherry pick cart and other machines to reach the elevated heights (apportioned on monthly cost basis ).(Twice every month.) 15 Charges for underground reservoir ( once in every quarter) & Over Head tank cleaningOverhead 15000 lts (5000X3) and underground 455000 lts ( 6 tanks) using Sodium Hypochlorite & UV. (apportioned on monthly cost basis ). 16 AddG.S.T. @ 18% from Serial 01 to 10.05 17 Add Labour Welfare Cess @ 1% Serial 01 to 11
Contract Date: Jul 17, 2025 Contract Value : Ref. Document
Local Bodies No of Bidders 3
West Bengal View Result →
36.
Housing Urban and Rular Development #7595063 AOC
DEPOSIT-Govt. Medical College-Manathavadi-CCTV-Supply and Installation of CCTV at Govt. Medical College-Manathavadi-General Electronics Work- 1 CCTV 2 OD270026/2024-2025:Supply and installation of 4MP Fixed Starlight IR Bullet/Dome Camera, Focus: 4mm (2.8 mm for Dome), Smart IR Range: Up to 30 m, Built-in Mic, SD Card Slot, Reset Button , 120dB WDR , H.265+/H.265/H.264 , Up to 2592x1520 @25fps , Image Sensor 1/2.8 inch CMOS , Signal System PAL/NTSC , Min. Illumination Color: 0.002Lux@ (F1.6, ACG ON), B/W: 0Lux with IR , Shutter Time : 1s to 1/100,000s , Day and Night: Dual IR Cut Filter with Auto Switch , Aperture F1.6, Fixed , Wavelength 850nm , Video Bit Rate : 32Kbps~6Mbps , Audio Compression G.711/G.711U/ADPCM , Audio Bit Rate 8K~48Kbps , Main Stream PAL: 25fps (2592x1520, to 1280x720) NTSC: 25fps (2592x1520, 2560x1440), 30fps (2304x1296, 1920x1080, 1280x720) , Sub Stream PAL: 25fps (704x576, to 352x288) NTSC: 30fps (704x480, to 352x240) , Image Enhancement:BLC/3D DNR/HLC , OSD : 16x16, 32x32, 48x48, 64x64, adaptable size, Letters Such as Week, Date, Time, Total 3 Regions , Privacy Mask 4 regions , Smart Defog , Alarm Trigger : Motion Detection, Mask Alarm, IP Address Conflict , Video Analytics : Tripwire, Perimeter , ANR : Auto store video in SD card when NVR disconnected, and upload video to NVR when resumed connection , Protocols : TCP/IP, HTTP, FTP, DHCP, DNS, DDNS, MULTICAST, IPV4, NTP, UDP, Telnet , ONVIF (PROFILE S/T/G) , Communication Interface : 1 RJ45 10M/ 100M self adaptive Ethernet port , Audio I/O : Mic in , Reset Button , Built-in MicroSD card slot, up to 512 GB , Protection : IP67, Lightning protection, surge protection and voltage transient protection , Power Consumption MAX: 6W (12V) MAX: 7W (PoE) , Power Supply DC 12V +/- 25%, PoE (802.3af) ; Preferred Make : Honeywell I-HIB4PI-LS/I-HIE4PI-LS or equivalent 3 OD270025/2024-2025:Supply and installation of project series Network Video Recorder, support 64 Channel, Should support Resolution:- greater than equal to 12 MP IP Camera, Network Bandwidth incoming 640 Mbps and outgoing 640 Mbps for access, support for H.265+/H.265/H.264 encoding format streaming access and decoding output, Recording play back quality: 16 ch play back simultaneously, Recording resolution up to 12MP, Recording mode: support manual, Auto, Motion detection, Alarm, trigger record mode,Operation way: Mouse, local Login: Username and password, Recording storage: Local HDD, network, Video output: HDMI/VGA/TV, Support min. 8 SATA HDDs , Each port supports min. 18TB HDD(Enterprise class),support-RAID0, RAID1, RAID5, RAID6, RAID10,Support dual Gigabit Ethernet ports, Supports 4 HDMI outputs with a maximum of 4K HD output, Alarm Input/out:16 in /4 out ,Audio:1 in / 1 out ,Supports intelligently Supports intelligent analytics such as facial detection, Pedestrian Detection, human detection, vehicle detection, Licence plate recognition, perimeter intrusion, and line crossing statistics ,product must comply with NDAA compliance, Non Black Listed Declaration , Own Mac Address Declaration , Onvif Membership Declaration, Certification: BIS,CE,FCC,ROHS ,ISO:9001;Preferred make: Honeywell I-HPNVR-864 or equivalent 4 OD266903/2024-2025:Supply and installation of project series Network Video Recorder, support 32 Channel,Should support Resolution:- greater than equal to 12 MP IP Camera, Network Bandwidth incoming 320 Mbps and outgoing 320 Mbps for access, support for H.265+/H.265/H.264encoding format streaming access and decoding output, , Recording play back quality: 16 ch play back simultaneously, Recording resolution up to 12MP, Recording mode: support manual, Auto, Motion detection, Alarm, trigger record mode,Operation way: Mouse, local Login: Username and password, Recording storage: Local HDD, network,Video output: HDMI/VGA/TV, , Support min. 4 SATA HDDs , Each port supports min. 12TB HDD, Support dual Gigabit Ethernet ports, Supports 2 HDMI outputs with a maximum of 4K HD output, Alarm Input/out:16 in /1 out ,Audio:1 in / 1 out ,Voice command: Home Device: Google Assistant, Amazon Alexa, Supports intelligent analy Supports intelligent analytics such as facial recognition, human detection, vehicle detection, Licence plate recognition, perimeter intrusion, and line crossing statistics, product must comply with NDAA compliance, Non Black Listed Declaration , Own Mac Address Declaration , Onvif Membership Declaration, Certification: BIS, CE, FCC,ROHS ,ISO 9001:20015; Preferred make: Honeywell I-HPNVR-432 or equivalent 5 OD266257/2024-2025:Supply and installation of 10TB HDD. Preferred Make: Seagate, WD, Toshiba 6 OD262539/2024-2025:Supply and installation of 43 inch or above 4k Television suitable for working 24x7, WiFi, Bluetooth, 2 HDMI inputs, etc. supplied with all necessary accessories including wall mounting kit . Preferred Make: LG UR801C, Panasonic, Samsung, Sony. 7 OD262542/2024-2025:Supply and installation of wireless mouse for NVR. Preferred Make: Dell,HP,Lenovo,Logitech 8 OD265380/2024-2025:Supply and installation of high speed HDMI cable with 5 meter length, Supports 4K@60MHz, 2160p, 1080p and 3D and Audio Return, 60 Megabytes Per Second Data Transfer Rate, etc. Preferred Make: MX or equivalent 9 Networking 10 OD263199/2024-2025:Supply, install and commissioning of 8 port L2 smart managed gigabit switch with 8 x 10/100/1000 BASE-T ports, 2 x SFP ports, etc. supplied with all necessary accessories. Preferred make: D-Link /Netgear or equivalent 11 OD262735/2024-2025:Supply and Installation of 16 port Unmanageable PoE switch with16 10/100/1000 Mbps gigabit ethernet ports, 2 SFP port, 150watts available PoE, Flow control for protection against data loss, Port 1-8 can support up to 250m, etc. supplied with 19 inch Rack mounting brackets. Preferred Make: D-Link DGS- DGS-F1018P or equivalent. Supply and Installation of 16 port Unmanageable PoE switch with16 10/100/1000 Mbps gigabit ethernet ports, 2 SFP port, 150watts available PoE, Flow control for protection against data loss, Port 1-8 can support up to 250m, etc. supplied with 19 inch Rack mounting brackets. Preferred Make: D-Link /Netgear or equivalent 12 OD262555/2024-2025: Supply, Installation, Testing and Commissioning of10 port 10/100/1000Mbps Switch with 8 x10/100/1000 BASE-TPoEports, 2 x 10/100/1000 BASE-T Uplink ports with 20 Gbps switching capacity,96 W Power Budget supplied with all necessary accessories. PreferredMake: D-Link DES-F1010P-E or equivalent 13 OD265359/2024-2025:Supply and installation of SFP transceiver module with speed: 1.25 Gbps, Duplex LC connector suitable for above switch. Preferred make:D-Link /Netgear or equivalent 14 OD262574/2024-2025:Supply and fixing of UL certified 19 inch 6U Rack with Front Glass door and lock and all mounting hardware including Horizontal Cable organizer suitable for 19 inch Rack, 2U standard, 230V 6A Inlet Plug type Indian Round Pin 6 Nos, Power Distribution Unit, 8A Fuse, ,Air circulation module 90CFM. Preferred Make: D-Link, Netrack, Valrack 15 OD265348/2024-2025:Supply and fixing of UL certified 19 inch 9U Rack with Front Glass door and lock and all mounting hardware including Horizontal Cable organizer suitable for 19 inch Rack, 2U standard, 230V 6A Inlet Plug type Indian Round Pin 6 Nos, Power Distribution Unit, 8A Fuse, ,Air circulation module 90CFM. Preferred Make: D-Link, Netrack, Valrack 16 OD265346/2024-2025:Supply and installation of UL listed, ETL verified 1U , 24 port Rack mountable Enhanced Modular type unloaded Patch Panel with rear cable organizer made of cold rolled steel, powder coated, front labelling Facility and suitable for RJ 45 CAT 6/CAT6A Keystones and labelling as required. Preferred make: Molex, Honeywell, Commscope,Norden 17 OD265349/2024-2025:Supply, termination, testing, and commissioning of UL Listed, ETL verified CAT 6 Keystone Jack with dust protection, suitable for 22- 24 AWG bare copper conductor,Minimum 500 insertion cycles and 100 reterminations, as per TIA/EIA 568-B colour code conforming to the standards ANSI/TIA-568.2-D , ISO/IEC 11801, IEEE 802.3, ISO/IEC 60332-1,and RoHS Complaint. Preferred make: Molex, Honeywell, Commscope Norden 18 OD265350/2024-2025:Supply, installation, testing, and commissioning of UL Listed, ETL verified 0.5 meter CAT 6 UTP Patch Cord having LSZH jacket, 24 AWG bare copper conductor UTP 4 pair both end factory Crimped with modular male plugs with minimum 500 insertion cycles terminiated as per TIA/EIA 568-B colour code conforming to the standards ANSI/TIA-568.2 , ISO/IEC 11801, IEEE 802.3, ISO/IEC 60332-1,and RoHS Complaint. Preferred Make: Molex, Honeywell, Commscope, Norden 19 OD265351/2024-2025:Supply, installation, testing and commissioning of Unloaded 1U Rack mountable LIU Supporting 16SC/32LC with splice tray, cable manager and with sufficient blanking plug to cover unused slots.Preferred Make: Commscope, Honeywell, Legrand, Molex 20 OD265353/2024-2025:Supply, installation, testing and commissioning ofduplex UPC/APC SC/LC Flange Mount connector with insertion loss 0.02dB or better, RoHS compliant and suitable for existing LIU.Preferred Make: Commscope, Honeywell, Legrand, Molex 21 OD265352/2024-2025:Supply, installation, testing and commissioning of 1m Duplex UPC/APC SC/LC Fiber pig tail confirming to LS0H IEC 61034-1 & 2, IEC-60332-1, IEC60754-1 & 2, ISO/IEC 11801-1:2017, ANSI/TIA/ EIA 568.3-D,ANSI/TIA/EIA-492 standards for terminating fiber in LIU/SFP module. Preferred Make: Commscope, Honeywell, Legrand, Molex 22 OD265354/2024-2025:Supply, installation, testing and commissioning of 1m Duplex UPC/APC UPC/APC SC/LC Fiber patch cord confirming to LS0H, IEC 61034-1 & 2, IEC-60332-1, IEC60754-1 & 2, ISO/IEC 11801-1:2017, ANSI/TIA/ EIA 568.3-D,ANSI/TIA/EIA-492, RoHS standards and suitable for existing SFP module. Preferred Make: Commscope, Honeywell, Legrand, Molex 23 UPS 24 OD265449/2024-2025:Supply and installation of 1KVA with BIS/CE certified IGBT based online UPS with 2 numbers of 12v, 7Ah batteries including all necessary accessories. Preferred Make: Hykon,Luminous,Microtek,Zenster 25 Cabling 26 OD27147/2025-2026:Supply, drawing. testing and commissioning of UL certified and ETL verified 23 AWG bare copper conductor UTP 4 pair Unarmoured CAT 6 cable with HDPE Insulation Material and LSZH Outer Jacket, conforming to the standards ANSI/TIA-568.2-D, ISO/IEC 11801, IEEE 802.3, ISO/IEC 60332-1,ISO/IEC 61034-2,ISO/IEC 61754-2,Colour Code as per TIA/EIA 568-B, RoHS Compliant, transmission performance tested up to 500 MHz or better and Insertion Loss/ Attenuation: 33 dB/100m or better at 250 MHz in the existing surface/recessed steel/PVC conduit as required 2 run of Cable. Preferred Make: Commscope, Honeywell, Molex. 27 OD27166/2025-2026:Supply, drawing. testing and commissioning of UL certified and ETL verified 23 AWG bare copper conductor UTP 4 pair Unarmoured CAT 6 cable with HDPE Insulation Material and LSZH Outer Jacket, conforming to the standards ANSI/TIA-568.2-D, ISO/IEC 11801, IEEE 802.3, ISO/IEC 60332-1,ISO/IEC 61034-2,ISO/IEC 61754-2,Colour Code as per TIA/EIA 568-B, RoHS Compliant, transmission performance tested up to 500 MHz or better and Insertion Loss/ Attenuation: 33 dB/100m or better at 250 MHz in the existing surface/recessed steel/PVC conduit as required 1 run of Cable. Preferred Make: Commscope, Honeywell, Molex 28 OD265382/2024-2025:Supply, laying, and commissioning of Optical Fiber Cable containing 6 core, 9/125μm, OS2 Type outdoor metal free, jel free single mode optical fiber cable , HDPE UV stabilized outer sheath, anti-Rodent, anti-termite and conforming to the standards ISO/IEC 11801, RoHS. 29 1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm 30 1.21.2:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm 31 14.15.1:Supplying and laying of following size owe HOPE pipe .lSI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required.63 mm· dia (OD-63 mm & ID-51 mm nominal) 32 14.1:Excavation for foundation in soft soil including dressing of sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 metres.
Contract Date: Jul 14, 2025 Contract Value : 14.33 Lakh
Government Departments No of Bidders 6
37.
Law and Justice #7562623 AOC
Tender For supply installation testing and commissioning Of Additional Work Of Cctv System At Eklavya Model Residential School, Mukut Manipur, Bankura At Bcwtd Office, Nutanchati, Bankura- 1 SITC ofGigabit switch, Ethernet, 8 Port +Switch to be operated on 200-240VAC, 50 Hz Supply, , having minimum technical specification : a) 8 x 10/100/1000 Base-T host ports with minimum PoE budget 120Watt(minimum). b) 2x 1GE SFP ports and field replaceable SFP module of same rating. c)Minimum switching capacity of 20Gbps. d)Applicable Standards:IEEE 802.1p: CoS prioritization , IEEE 802.1Q: VLAN tagging,IEEE 802.1v, IEEE 802.3ad, IEEE 802.1X: Port Access Control,Spanning Tree Protocol,Multiple instances of Spanning Tree Protocol (MSTP), IEEE 802.1w: Rapid reconfiguration of Spanning Tree Protocol, IEEE 802.3ad: Link Aggregation Control Protocol. j)Operating Temperature- upto 45degree C. (Make: WBOX/D-Link/TP-Link/Netgear). 2 SITC of Workstation PC for remote monitoring Core i5/i7 processor 12th Generation 16/32GB DDR-3 or 4 RAM 2GB dedicated ATI-Radeon Graphics Card,512 GB SSD for Windows 11 Professional Operating System (Licensed version) and booting,1TB SATA-III HDD X 2 nos for VMS application. Make: Lenevo/Dell/HP or reputated. 3 SITC of Multi Mode Media Converter OFC to CAT6-RS232- RS485 com mode with patch cord. Make: D-Link/TP Link/Netgear or Reputated. 4 SITC of Networking Horizontal Cable, 1000Base-T (Gigabit Ethernet), 100Base-T (Fast Ethernet), 10BaseT (Ethernet),1-250 MHz (Minimum), Category 6, 4-Pair, U/UTP, 23 AWG solid bare copper conductors with FEP Insulation, polyester separator, LSZHOUTER sheath COVER as to standard of ISO/IEC 11801Ed. 2.0, EN 50173-1 with Accessories. make:3C3/Legrand/D-Link/Finolex/Wbox. 5 Supply and laying ofHDMI cable 5mtr.Make - MX/ ATEN/ Finolex or reputated. 6 SITC of UPS Offline 1 KVA with 30 min battery back up.Make: Vertib/APC/DELTA/Microtek 7 SITC of WALL mounted Cross Connect Equipments 2U x 500 x 500 Rack - Front Glass Door with Cam Lock. Make:Netrack/Valrack/D-Link/APW. 8 SITC of OFC pigtail and Joint BOX. Make: Reputated. 9 SITC of Alluminium wire. Make: Local Reputated 10 SITC of VMS software for remote Display 11 SITC OFSingle Mode ( 6 Core), Uni Tube, anti rodent, ELECTRO CROMIUM COROGATED STEEL TAPE ARMOURED, 6 Fiber, 50/125 Micron, type OS2; AS/ACIF S008; AS/NZS 3080,ITU-T REC G 652D,AS/NZS 3080; IEC 60332-1; suitable for use in direct burial, outdoor ducts and backbone cabling; Corrugated Steel Tape Armour -Thickness > 0.125mm; Loose tube material : Single PBTP Loose tube filled with water blocking Thixotropic gel; Jacket material: UV Stabilised Polyethylene (HDPE); Operating Temperature : -10 Degree C to +70 Degree C; Tensile Strength : 1000N; Crush Resistance : 2000N/10cm. Make (3C3/Molex/D-Link/Finolex).
Contract Date: Jul 04, 2025 Contract Value : 9.38 Lakh
Local Bodies No of Bidders 3
West Bengal View Result →
38.
Housing Urban and Rular Development #7310921 AOC
Tender For Modernization Work Of Veer Bahadur Singh Planetarium, Gorakhpur. (Part A And C) - EARTH WORK 2 Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil (D.S.R. No-2.8.1/2023) 3 Filling available excavated earth (excluding rock) in trenches, plinth,sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. (D.S.R. No-2.25/2023) 4 Construction of embankment with approved materials deposited at site from roadway cutting and excavation from drain and foundation of other structures graded and compacted to meet requirement (AR) (lead upto 10km) (Morth Based) 5 CONCRETE WORK 6 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : (D.S.R. No-4.1/2023) 7 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size) (D.S.R. No-4.1.8/2023) 8 REINFORCED CONCRETE WORK 9 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : (D.S.R. No-5.1/2023) 10 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size). (D.S.R. No-5.1.2/2023) 11 Centering and shuttering including strutting, propping etc. and removal of form for all heights :(D.S.R. No-5.9/2023) 12 Foundations, footings, bases of columns, etc. for mass concrete (D.S.R. No-5.9.1/2023) 13 Lintels, beams, plinth beams, girders, bressumers and cantilevers (D.S.R. No-5.9.5/2023) 14 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. (D.S.R. No-5.22/2023) 15 Thermo-Mechanically Treated bars of grade Fe-500D or more (D.S.R. No-5.22.6/2023) 16 Brick work with common burnt Clay F.P.S (non modular ) brick of class designation 7.5 in foundation and plinth in: (D.S.R. No-6.1/2023) 17 Cement mortar 1:4 (1 cement : 4 coarse sand) (D.S.R. No-6.1.1/2023) 18 MILD STEEL AND IRON WORK 19 Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.10.25.1 In stringers, treads, landings etc. of stair cases, including use of chequered plate wherever required, all complete (D.S.R. No-10.25.1/2023) 20 In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works (D.S.R. No-10.25.2/2023) 21 Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. (D.S.R. No-10.1/2023) 22 Structural steel work riveted, bolted or welded in built up sections,trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. (D.S.R. No-10.2/2023) 23 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete, (D.S.R. No-10.16/2023) 24 Hot finihed seamless type tubes(Taken 40kg per sqm weight)boundry grill (D.S.R. No-10.16.2/2023) 25 FLOORINGWORK 26 Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete.11.3.1 40 mm thick with 20 mm nominal size stone aggregate. (D.S.R. No-11.3/2023) 27 Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm thickgallaries (D.S.R. No-11.26/2023) 28 FINISHING 29 12 mm cement plaster of mix :1:4 (1 cement: 4 coarse sand) (D.S.R. No-13.4.1/2023) 30 Finshing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufactures specifications: (D.S.R. No-13.48.1/2023) 31 Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of special primer applied @ 0.75 ltr/10 sqm 32 Painting steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture. (D.S.R. No-13.4.3/2023) 33 DEMOLITION 34 Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in-charge.(D.S.R. No-15.3/2023) 35 Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. 15.7.4 In cement mortar(D.S.R. No-15.7.4/2023) 36 Dismantling stone slab flooring laid in cement mortar including stacking of serviceable material and disposal of unserviceable material within 50 metres lead. (D.S.R. No-15.25/2023) 37 Dismantling old plaster or skriting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 meters lead. (D.S.R. No-15.56/2023) 38 Stone work (machine cut edges) for wall lining etc. (veneer work) upto 10 metre height, backing filled with a grout of average 12 mm thick cement mortar 1:3 (1 cement: 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement: 2 stone dust) with an admixture of pigment matching the stone shade: (To be secured to the backing and the sides by means of cramps and pins which shall be paid for separately):(D.S.R. No-8.14/2023) 39 40 mm thick white sand stone - Exposed face machine cut and table rubbed with rough backing. (D.S.R. No-8.14.2.4/2023) 40 Providing and fixing cramps of required size & shape in RCC/CC/Brick masonry backing with cement mortar 1:2 (1 cement 2 coarse sand), including drilling necessary hole in stones and embedding the cramp in the hole (fastener to be paid separately). (D.S.R. No-8.7/2023) 41 Gunmetal cramps(2081/0.36)= 5780.55 say 5780.00 (D.S.R. No-8.7.1/2023) 42 Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete (D.S.R. No-8.8/2023) 43 Fastner with threaded dia 10mm (D.S.R. No-8.8.1.2/2023) 44 ELECTRICAL WORK 45 SUB-Head SH:- I (Wiring) Wiringforlightpoint/fanpoint/exhaust fanpoint/callbellpointwith1.5sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copperconductorsinglecorecableetcas required. (D.S.R. No-1.3) 46 (a) GroupC (D.S.R. No-1.3.3) 47 (b) GroupB (D.S.R. No-1.3.2) 48 (c) GroupA (D.S.R. No-1.3.1) 49 Wiring for twin control light point with 1.5 sq.mm FR PVC insulated copper conductor singlecorecableinsurface/recessedsteel conduit,2waymodularswitch,modular plate ,suitable GI box and earthing the point with1.5sq.mm.FR PVCinsulatedcopper conductor single core cable etc as required. (D.S.R. No-1.4) 50 Wiringforgroupcontrolled(looped)light point/fanpoint/exhaustfanpoint/callbell point (without independent switch etc.) with 1.5sq.mmFRLSPVCinsulatedcopper conductor single core cable in surface/ recessed steel conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copperconductorsinglecorecableetc.as required. (D.S.R. No-1.54) 51 GroupC (D.S.R. No-1.54.3) 52 Wiring for light/ powerplug with 2X4 sq. mm FRLS PVC insulated copper conductor singlecorecableinsurface/recessedsteel conduitalongwith1No4sq.mmFRLS PVC insulated copper conductor single core cable for loop earthing as required. (D.S.R. No-1.5) 53 Wiring for light/ powerplug with 4X4 sq. mm FRLS PVC insulated copper conductor singlecorecableinsurface/recessedsteel conduitalongwith2Nos4sq.mmFRLS PVC insulated copper conductor single core cable for loop earthing as required. (D.S.R. No-1.6) 54 Wiring for circuit/ submain wiring alongwithearthwirewiththefollowing sizes of FRLS PVC insulatedcopper conductor, single core cable in surface/ recessed steel conduit as required (D.S.R. No-1.7) 55 (a) 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire (D.S.R. No-1.7.1) 56 (b) 2 X 6 sq. mm + 1 X 6 sq. mm earth wire (D.S.R. No-1.7.4) 57 (c) 4 X 6 sq. mm + 2 X 6 sq. mm earth wire (D.S.R. No-1.7.9) 58 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/ PVC conduit as required. (D.S.R. No-1.17) 59 (a) 6 x 1.5 sq. mm (D.S.R. No-1.17.6) 60 (b) 9 x 1.5 sq. mm(D.S.R. No-1.17.9) 61 Supplyinganddrawingfollowingpair0.5 sqmmFRLSPVCinsulatedcopper conductor,unarmoredtelephonecablein theexistingsurface/recessedsteel/PVC conduit as required.(D.S.R. No-1.18) 62 2 Pair (D.S.R. No-1.18.2) 63 Supplyinganddrawingco-axialTVcable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required. (D.S.R. No-1.19) 64 Supplyingandfixingoffollowingsizes of steel conduit along with accessories in surface/recess including painting in case of surfaceconduit,orcuttingthewalland makinggoodthesameincaseofrecessed conduit as required. (D.S.R. No-1.20) 65 25mm (D.S.R. No-1.20.2) 66 Supplyingandfixingfollowingsize/ modules, GI box alongwith modular base & coverplateformodularswitchesinrecess etc as required. (D.S.R. No-1.27) 67 (a )2 Module (75mmX75mm) (D.S.R. No-1.27.2) 68 (b) 6 Module (200mmX75mm) (D.S.R. No-1.27.4) 69 (c )12 Module (200mm X 150mm) (D.S.R. No-1.27.6) 70 Supplying and fixing followingmodular switch/ socket on the existing modular plate &switchboxincludingconnectionsbut excluding modular plate etc. as required. (D.S.R. No-1.24) 71 5/6 amps switch (D.S.R. No-1.24.1) 72 3 pin 5/6 amp socket outlet (D.S.R. No-1.24.4) 73 Telephone socket outlet (D.S.R. No-1.24.6) 74 TV antenna socket outlet (D.S.R. No-1.24.7) 75 LAN socket outlet Cat 6-UTP- 1 Module (MR) 76 SupplyingandfixingsuitablesizeGIbox withmodularplaeandcoverinfronton surfaceorinrecess,includingproviding andfixing3pin5/6ampsmodularsocket outletand5/6amps modularswitch, connection,paintingetc.asrequired.(For light plug) (D.S.R. No-1.31) 77 SupplyingandfixingsuitablesizeGIbox withmodularplaeandcoverinfronton surfaceorinrecess,includingproviding and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection, painting etc. as required. (D.S.R. No-1.32) 78 Supplying&fixingtwoModuleGIbox wihmodularplateandcoverinfronton surface or in recess including providing and fixing 16 A modular socket outlet and 16 A modular SP MCB, C curve in one or two ModuleGIboxwihmodularplateand cover, including connections, painting etc. as required. (MR) 79 Supplyingandfixingtwomodulestepped type electronic fan regulator on the existing modular plate switch box including connectionsbutexcludingmodular plate etc. as required (D.S.R. No-1.25) 80 Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed steel/ PVC conduit as required. (D.S.R. No-1.53) 81 1 run of cable(D.S.R. No-1.53.1) 82 2 run of cable(D.S.R. No-1.53.2) 83 3 run of cable(D.S.R. No-1.53.3) 84 Sub-Head-II (Fitting & Accessories) 85 Supplying and fixing call bell/ buzzer suitableforD.C./A.C.singlephase,230 volts,completeasrequired.(suitablefor fixing in 2 Module box)(D.S.R. No-1.38) 86 Supply InstallatitonTesting and Commissioning of energy efficient direct fit (Retrofit)Polycarbonate/Glasshousing SMDMidPower20WattLEDtuberod (withintegraldriver& alumn. heatsink), onexisting fixture. systemlumenefficacy ≥100 lm/Watt output, internalsurge protectionof2.5KV,THD<20% ,p.f.≥0.95,CRI>80 , life time of minimum 35000BurningHourswith,70%ofintial Lumenmaintanedtilllifeends , CCT 3000°K /4000°K/ 5700°K/6000°K/6500°K (As per ANSI Bin), maximumpowerconsumptionshouldnot morethanthespecifiedratingandFixture (MR) 87 1200mm,Min.Lumensoutput2000lm LED Tube rod with Polycarbonate Housing 88 Supply InstallatitonTesting and CommissioningofIP20boxmadeout from1.2mmthickCRCAsheetsteelwith depth of minimun 30 mm and finished with powdercoating and suitable formounting LED tube including side overs, holders , internal wiring to illuminate the single sided connection LED tube. ( Without tube).(MR) 89 Suitable for 4 LED Tube shape fixturefor single rod 90 Supply,installation,testingand commissioningofheavyduty, 230Volts, single phase AC supply 300mm dia exhaust fanWITH900RPMdoubleballbearing, withenegyefficentmotor,louver/shutter, birdscreenincludingallaccessoriesand with 3 core flexible wire complete as required,intheextingopening,including making the hole to suit the size of the above fan,makinggoodthei/cfixingof louver/shutter etc.as required. (MR) 91 Supplying and fixing of 250mm sweep decorativeFreshairfanwithall accessories suitable for operation single phase 230 volt 50 cycle per second per sec. ACsupply etc.as required. inthe existing opening, includingmakingthe holetosuit the size of the above fan, making good the damage, connection, testing, commissioning earthing etc. as required. (MR) 92 Supply InstallatitonTesting and Commissioning of 1200mm sweepceiling fancapacitor type with double ball bearing complete with capacitor , suitable down rod , canopies , shackles, three number Al.blade & suitable for operation on 230 volt 50 Hz single phase AC supply i/c wiring the down rod of standard length (upto 30cm) with 1.5 sq.mm FR PVC insulated copper conductor singlecorecablei/cprovidingandfixing laminated sheet cover 3mm thick on the fan box etc as reqd. (Minimum Service Value 4.00 and above) (MR) 93 Supply InstallatitonTesting and Commissioning of IP-20 12 Watt LED Recessed / Surface Mounted, Round / Sqaure SMDMidPowerLEDDownlight withpowercoateddie-castaluminum housing with UV Stabilized non yellowish Diffuser with BIS complience 2.5KV surgeprotectedIsolateddriver,withShort & Open circuit protection, having efficiency > 85% . System Lumenefficacy of ≥ 110 lm / watt, THD < 10 % , Pf.≥0.95, CRI>80,lifetimeofminimum50000 Burning Hours with , 70% of intial Lumen maintanedtilllifeends,CCT3000°K/ 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption shouldnotmorethanthespecifiedrating andFixtureshallbeof BISstandardand trade mark certificate ( T.C.). (MR) 94 Minimum lumen output 1300 lm (AR) 95 Supply InstallatitonTesting and CommissioningofIP-20LEDRecessed/ SurfaceMounted,Round/SqaureSMD MidPower18WattLED Downlightwith powercoateddie-castaluminumhousing withUV Stabilized nonyellowishDiffuser with BIS complience 2.5 KV surge protected Isolated driver, with Short & Open circuit protection, having efficiency > 85% . System Lumen efficacy of ≥ 110 lm / watt, THD < 10 % , Pf.≥0.95, CRI >80,life timeofminimum50000BurningHours with,70%ofintialLumenmaintanedtill life ends, CCT 3000°K / 4000°K/5700°K/6000°K/6500°K (As per ANSI Bin), maximumpowerconsumptionshouldnot morethanthespecifiedratingandFixture shallbeof BISstandardand trademark certificate ( T.C.). (MR) 96 Minimum lumen output 1950 lm 97 Supply InstallatitonTesting and Commissioning ofIP65IK08rated Integrated SMD Mid power LED bulk head typelightfixturemadefromPressureDie Cast AL housing suitable with integral driver, system lumen efficacy ≥100 lm/Watt output,THD<10%,p.f.≥0.95,CRI>80, life time of minimum 50000 Burning Hourswith ,70%ofintialLumen maintanedtilllifeends,CCT3000°K/ 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption shouldnotmorethanthespecifiedrating andFixtureshallbeof BISstandardand trademarkcertificate(T.C.).surge protection 4 KV.(MR) 98 Supplying installation testing and commissioning of Surface / Wall mounted LED Batten (10w LED mirror light) fitting systemlumensoutputnotlessthan 100,PowerFactor≥0.90,CRI>80,THD 10%,CCT5500-6600K(asrequired) extrudedAluminiumhousingprovidedfor efficient head dissipation with polycarbonatediffuser& integrated electronicdriverwithallaccessorieswith 1.5sqmm.,PVCinsulated,FRLScopper conductor, single core cable etc. as required & as per make & models in enclosed list of approved makes as required. (MR) 99 Supplying & fixing decorative wall bracket fitting made of poly carbonate with vitreous enamelledglass glob fixed on wall i/c1No.Retrofit10wattLEDlamp& connections,testing&commissioningetc complete as reqd. (MR) 100 Supplying installation testing and commissioningof400mmsweep,50W, 1370RPM,Wallfansuitablefor single phase 230 Volts 50 Hz AC supplyi/c testing, commissioning etc as required. (MR) 101 Sub Head-III (MCBs,MCB DBs, & Energy Meter) 102 Supplyingandfixingfollowingway, horizontal type three pole and neutral, sheet steel,MCBdistributionboard,415V,on surface/recess,completewithtinned copperbusbar,neutralbusbar,earthbar, dinbar,interconnections,powderpainted includingearthingetc.asrequired. (But without MCB/RCCB/Isolator)(D.S.R. No-2.4) 103 8way (4 +24),Double door(ForType V Qtr.) (D.S.R. No-2.4.3) 104 Supplyingandfixingoffollowingways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel,dustprotected,dulypowderpainted, inclusiveof200ampstinnedcopperbus bar, common neutral link, earth bar, din bar formountingMCBs(butwithoutMCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) (D.S.R. No-2.5) 105 12 way (4 + 36), Double door (For School) (D.S.R. No-2.5.3) 106 Supplying and fixing following way, single poleandneutral,sheetsteel,MCB distribution board, 240 V, on surface/ recess,complete with tinned copper bus bar, neutral bus bar, earth bar,din bar, interconnections,powderpaintedincluding earthing etc. as required. (But without MCB/RCCB/Isolator) (D.S.R. No-2.3) 107 16way,Doubledoor(ForType-II&III Qtrs and light DB) (D.S.R. No-2.3.4) 108 SupplyingandfixingDPsheetsteel enclosure on surface/recess along with 25/32 A, 240 V “C” curve DP MCB complete with connections, testing and commissioningetc.asrequired.(ForStair Case Lights)(D.S.R. No-2.16) 109 Supplying and fixing following rating, four pole, 415 volts, MCB in the existing MCB DB complete withconnections, testing and commissioning etc. as required. 63 amps (MR) 110 Supplyingandfixing5ampsto32amps rating, 240 volts, C series, miniature circuit breaker suitable for inductive load of followingpolesintheexistingMCBDB complete with connections, testing and commissioning etc. as required.(D.S.R. No-2.10) 111 Single pole (D.S.R. No-2.10.1) 112 Double pole (D.S.R. No-2.10.3) 113 Supplying and fixing Cable End Box (Loosewirebox)(IP43)suitablefor following single pole andneutral, sheet steel,MCBdistributionboard,240V,on surface/recess,completewithtestingand commissioning etc. as required. (D.S.R. No-2.23) 114 For 14 way, Double door SPN MCBDB (D.S.R. No-2.23.4) 115 Supplying and fixing Cable End Box (Loosewirebox)(IP43)suitablefor following triple pole and neutral, sheet steel,MCBdistributionboard,415V,on surface/recess,completewithtestingand commissioning etc. as equired. (D.S.R. No-2.24) 116 For 8 way, Double door TPN MCBDB (D.S.R. No-2.24.3) 117 Supplying and fixing following rating, four pole, 415 volts, MCCB in the existing VerticalTPNDBcompletewith connections, testing and commissioning etc. as required. (D.S.R. No-2.2) 118 3 pole MCCB, 100A, 16KA (D.S.R. No-2.2.1) 119 Supplying and fixing Cable End Box (Loose Wire Box) suitable for triple pole and neutral, sheet steel, Vertical MCB distribution board, 415 Volts, on surface/recess, complete with testing and commissioning etc. as required. (D.S.R. No-2.25) 120 Supply & Erracetion of factory fabricated & wired metal clad dust and vermin proof floor mounting, M.S. Channel Base with bottom and top cable entreis Electrical control panel with TPN MCCBs (Four Pole 36 KA with thermal magnatic release) Switches Complete and instrument chamber etc.complete in all respects. The instrument chamber shall be separate and shall comprise of flush type digital metering system for phase to phase voltage and single phase voltage, current and other parameters(KVA,P.F,KW etc) in each phase with touch type selector switches for different readings, instrument fuses, current transformer etc. The panel board shall have suitable capacity electrolytic alumininum busbars as per IS8623 or above istulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/BMC support with deteachable side covers and shall be suitable for extension on the sides. The MCCBs shall be complete with suitable cable end boxes, compression glands and indicating lamp on incoming etc.The Job includes the grounting of the board as per directions of Engineer-in charge. All out goings of 100 Amp and above shall have an Ammeter. The panel board shall be fabricated with CRCA sheet with a minimum thickness of 1.6mm/2mm. Cubicle type switch board shall be of cat A & B Only. 121 Incoming 122 100 Amp MCCB-1 N0 123 Outgoning 124 63 Amp. MCCB-2 Nos. 125 Cat. A Pannel Cubicle Type 126 Cat. B Pannel Cubicle Type (S.I.No-811 (a) 127 32 Amp. MCCB-3 Nos. 128 Cat. A Pannel Cubicle Type 129 Cat. B Pannel Cubicle Type (S.I.No-811 (b) 130 SH IV( Meter Board & Panel ) 131 Distribution panel for School Building (Non-essential panel) 132 Supplying, installation, testing and commissioning of Indoor floor mounted modular,sectionalised,compartmentalized, dust&verminproof,extendabletypeMV cubiclepanelhaving 300mmdeepof suitable size notless then2.87sqmm fabricatedfrom CRCAsteelof2mm thick forframe work, enclosure and doors, 3 mm thick forgland plates withstiffeners wherever required i/c mounting base frame consistofMSchannelofsize100x50x6 mm,havingvibration freestructure chemically treated with seventankprocess beforepaintingforsurfacetreatmentand powder coated, with 4 nos. electrolytic gradehigh conductivity Aluminium busbar extensible type, DMC/SMC busbar supports, suitable for 3 phase 415 V 50 HZ ACsupplyi/callconnectionand interconnectionsinpanelboardwiththe suitablesizeFRLScopperwired/ALbus bars and 2 Nos. 25x5 mm copper earth bus bar through out the width of panel i/c earthing studs and detachable individual gland plate for each cable and having individualcompartmentforswitchgeari/c providing and fixing the following switchgearmounted thereoncomplete with connections & testing etc. as required. (Providing of connectors of required size insuitable quantity as per requirement.) 133 Note:-(i)Panelsizeindicatedisnominal.The actual sizeshall beasperthedrawing approved by the Department.(ii) All screws, nut bolts and earth stud are tobeusedofstainlesssteelonly.(iii) Panel have protection for Over Voltage and Under Voltage 134 All the MCCBs shall be Ics= 100% Icu 135 (II) INCOMING 136 a)250 Amps 36 KA FP MCCB with Ics= 100%Icu=36KA having thermal magnatic releases forO/L and S/C protection having extendablerotary handle, Spreader links, Aux. trip contact block, DigitalVAFmeterwithallrequired accesseries, LED indication lamp for R,Y & B, 2 Amp 10KA control MCB andtoggle switch with each MCCBi/c suitable size & capacity CTs as per requirement. 137 (III) OUTGOING 138 100 Amps FP MCCB with Ics= 100% Icu=30KAhavingthermalmagnaticreleases for O/L and S/Cprotection having extendable rotary handle, Spreader links for each MCCB 139 32 Amps TPN MCB (D.S.R. No-2.10.5) 140 DP MCB (32 amp) (D.S.R. No-2.10.3) 141 Danger notice plate (D.S.R. No-2.21) 142 Distribution panel for School Building(Essential panel) 143 Supplying, installation, testing and commissioning of Indoor floor mounted modular,sectionalised,compartmentalized, dust&verminproof,extendabletypeMV cubicle panel having 300 mm deep of suitable size fabricated from CRCA steel of2mmthickforframework,enclosure and doors, 3 mm thick for gland plates with stiffenerswhereverrequiredi/cmounting baseframeconsistofMSchannelofsize 100x50x6 mm, having vibration free structure chemically treated with seven tank process before paintingforsurface treatmentandpowdercoated,with4nos. electrolyticgradehighconductivity Aluminiumbusbar extensible type, DMC/SMCbusbarsupports,suitablefor3 phase415V50HZACsupplyi/call connectionandinterconnectionsinpanelboardwiththesuitablesizewiredcabble busbarsasperISand2Nos.25x5mm 144 copperearthbus bar throughout the width ofpaneli/cearthingstudsanddetachable individualglandplateforeachcableand havingindividualcompartmentforswitch gear i/c providing and fixing the following switchgearmounted thereoncomplete with connections & testing etc. as required. (Providing of connectors of required size in suitable quantity as per requirement.) 145 All the MCCBs shall be Ics= 100% Icu 146 (I) BUS BARS 147 4strip aluminium bus bars of minimum of 400 Amps, 16 KA for1 Sec. capacity with heat shrinkable coloured sleeves and includingDMC/SMCbusbarssupportsat requiredintervalscompleteforcross section, size supports at their spacing etc. for with standing fault level of 25 MVA for 1 Sec. The size of bus bar shall be provided considering the current densityof aluminium bus bar 1.0 Amp. /Sqmm. 148 Note:-(i)Panelsizeindicatedisnominal.The actual sizeshall beasperthedrawing approved by the Department.(ii) All screws, nut bolts and earth stud are tobeusedofstainlesssteelonly.(iii) Panel have protection for Over Voltage and Under Voltage 149 All the MCCBs shall be Ics= 100% Icu 150 (II) INCOMING 151 160Amps16KAFPMCCBwithIcs= 100%Icu=16KA having thermal magnatic releases forO/L and S/C protection having extendablerotary handle, Spreader links, Aux. trip contact block, DigitalVAFmeterwithallrequired accesseries, LED indication lamp for R,Y & B, 2 Amp 10KA control MCB andtoggle switch with each MCCB i/c suitable size & capacity CTs as per requirement 152 (III) OUTGOING 153 63 Amps FP MCCB withIcs= 100% Icu = 16KA having thermal magnatic releases for O/L and S/Cprotection having extendable rotary handle, Spreader links for each MCCB 154 32 Amps TPN MCB (D.S.R. No-2.10.5) 155 DP MCB (32 amp) (D.S.R. No-2.10.3) 156 Danger notice plate (D.S.R. No-2.21) 157 SH: V (Safety Equipment) 158 SITCofCarbonDioxide(CO2)gastype fireextinguisherof4.5Kg.capacitywith initialchargei/cdischargehoseandhorn, squeeze grip,release valve, locking arrangement,bracketwithtwoscrewand sleevei/cfixingonwall as required.(Fire extinguishershallbeoftype55BandISI marked confirming to IS: 15683) (MR) 159 Supplying&fixingofpowdertypefire extinguisher (stored pressur type confirmingtoIS:15683:2006)6Kg. capacitywithinitialrefillofISImarked ABCpowercompletedwithsqueezegrip, release valve, discharge pipe, pressure gauge,lockingsafetyclip,mounting bracketetc.i/cfixingonwallasrequired. (Fire extinguisher shall be ofMAP 90, type 3A, 55B) (MR) 160 Providing& fixingdangernotice plates madeofmildsteelatleast2mmthick& vitreousenameledwhiteonbothsides& withinscriptionsinsignalredcolouron front side as required. 161 Medium Voltage - Size 200mm x 150mm (D.S.R. No-2.21) 162 High Voltage- Size 250mm x 200mm (D.S.R. No-2.22) 163 Supply and fixing safety instruction chart in word duly framed with 5mm thick glass as required (Approx. Front area 1.20 Sq. Mtr.) (MR) 164 Providing of set of 4 Nos. 9.5 Litre capacity GI bucket painted in post office red colour with prior coat of red-oxide paint and writtenwithwhitepaintFIREand mounted on MSangle iron frame with bracketofappropriatesize&capacityi/c (MR) 165 filling sand etc. 166 Providing First Aid box as approved by St. John Ambulance Brigade/Indian Red Cross conforming to IS 2217-1963 (MR) 167 Supplyandfixingshocktreatmentchart dulymounted on a wooden frame with 5mm thickglass as required.(approximate front area 1.20 Sq. Mtr.) (MR) 168 Providing of rubber mat 1 mtr wide and 12 mmthicktowithstand3.3KVdielectric strength as per IS 5424 :1969 (MR) 169 Key board of size 30 cm x 30 cm made of iron dully painted and locking arrangement. (MR) 170 Rubber Gloves11KVgradeasper IS 4770-68 (MR) 171 SH:- VI (EARTHING) 172 Earthing with copper earth plate 600 mm X 600mmX3mmthickincluding accessories,andprovidingmasonry enclosurewithcoverplatehavinglocking arrangement and watering pipe of 2.7 metre long etc. (but without charcoal/ coke and salt ) asrequired. (D.S.R. No-5.5) 173 Providing and fixing 25 mm X 5mm copperstripin40mmdiaG.Ipipefrom earthelectrodeincludingconnectionwith brassnutbolt,spring,washerexcavation and re-filling etc. as required. (D.S.R. No-5.10) 174 Providing and fixing 25 mm X 5mm copperstriponsurfaceorinrecessfor connections etc. as required. (D.S.R. No-5.14) 175 Providingandfixing25 mmX 5mmG.I. stripin40mmdiaG.I.pipefromearth electrode including connection with G.I. nut, bolt, spring, washer excavation and re- filling etc. as required. (D.S.R. No-5.11) 176 Providingandfixing25 mmX 5mmG.I. strip on surface or in recess for connections etc. as required. (D.S.R. No-5.15) 177 Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required (D.S.R. No-5.2) 178 Providing and fixing 6 SWG dia G.I. wire on surface or in recessnfor loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. (D.S.R. No-5.18) 179 SH:- VII ( Lightening arrestor ) 180 Providing and fixing of lightning conductor finial,madeof25mmdia300mmlong, G.I.tube,havingsingleprongat top,with 85mmdia6mmthickG.I.baseplate including holes etc. complete as required. (D.S.R. No-6.2) 181 Jointingcopper/G.I.tape(withanother copper/GItape,baseofthefinialorany other metallic object) byriveting / nut bolting/ sweating and soldering etc as required. (D.S.R. No-6.4) 182 Providing and fixing G.I. tape 20 mmX 3 mm thick on parapet orsurface of wall for lightningconductorcompleteas required.(For horizontal run) (D.S.R. No-6.7) 183 Providing and fixing G.I. tape 20 mmX 3 mm thick on parapet orsurface of wall for lightningconductorcompleteas required.(For vertical run) (D.S.R. No-6.7) 184 a)63Amp.25KA4PoleMCCBwith thermal magnetic release and Extended Rotatory handle- 1 No.(Incomer) 185 b)DigitalMultifunctionLEDmeterclass 1.0, 96 Sqmm - 1 No. 186 c) Set of 3 Phase LED indicating Lamp - 1 Set 187 d) 63 Amp. TPN MCB=3 Nos. 188 e) 32 Amp. DP MCB=2 Nos. 189 f)DOLstartersuitableforupto10.0HP pump(ratingupto40A)completewith Motorprotectionrelayhavinginbuiltover load,earthfault,lockedrotorandsingle phasing protection feature complete with all accessoriesandinternalwiringwith minimum 2.5 Sqmm PVC insulated copper conductorwire required foroperation, selectorswtichforlocal/remote, auto/manual/OFF operation Attempt startingdevice,timersandrelaysas required, pushbuttons for start/stop in manual mode, 3 phase LED indication lamps with individual Toggle switch, Pump ON/OFFLEDindication,ControlMCB etc. = 2 Nos. (MR) 190 Providing, laying, testing & commissioning of C class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittingslikeelbows,tees,flanges,tapers, nutsbolts,gaskets etc.andfixingthe pipe onthewall/ceilingwithsuitable clamp/support frame and painting with two ormore coats of synthetic enamelpaintof required shade complete as required (D.S.R. No-18.7) 191 32 mm (D.S.R. No-18.7.2) 192 65 mm (D.S.R. No-18.7.5) 193 80 mm (D.S.R. No-18.7.6) 194 Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 ratingwithbronze/gunmetalseatdulyISI marked complete with nuts, bolts, washers, gasketsconformingtoIS13095of following sizes as required 195 65 mm dia (D.S.R. No-18.11.3) 196 80 mm dia (D.S.R. No-18.11.4) 197 Providing,installation,testingand commissioning of stainless steelY-strainer fabricatedoutof1.6mmthickstainless steel, Grade304, sheet with3mm dia holes with stainless steel flange. 80 mm dia (D.S.R. No-18.15.1) 198 Providing,installation,testingand commissioningofnon-returnvalveof following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required 80mm dia (D.S.R. No-18.14.4) 199 Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mmdiawithcastironwheelISImarked conforming toIS 5290 (Type -A) with blank Gunmetal/StainlessSteelcapandchainas required : (D.S.R. No-18.9) 200 Single headed Stainless steel (D.S.R. No-18.9.2) 201 Supplying and fixing 63 mm dia, 15 m long RRLhosepipewith63mmdiamaleand female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required : (D.S.R. No-18.16) 202 Stainless Steel (Grade 304) (D.S.R. No-18.16.2) 203 Supplying&fixing63mmdiagunmetal short branch pipewith 20mmnominal internal diameter size nozzle conforming to IS903suitableforinstantaneous connectiontointerconnecthosepipe coupling asrequired : (D.S.R. No-18.18) 204 Stainless Steel (Grade 304) (D.S.R. No-18.18.2) 205 Supplyingandfixingfirst-aidHoseReel with MS construction spray painted in post officered,conformingtoIS884complete with the followingasrequired. 20mm nominalinternaldiawaterhose thermoplastic (Textile reinforced) type -2 as perIS:1258520 mm nominalinternaldia gun metal globe valve & nozzle. Drum and bracketsforfixingtheequipmetsonwall. Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket 30m (D.S.R. No-18.17.1) 206 Supplyingandfixingoffirebrigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MSpipeconnectionconformingtoIS 904 as required 207 2 way-100 mm dia M.S. Pipe (D.S.R. No-18.19.1) 208 Supplying and fixing air vessel made of 250 mm dia, 8mm thick MS sheet, 1200 mm in heightwithairreleasevalveontopand flanged connectionto riser,drain arrangementwith25mmdiagunmetal wheel valve with required accessories, pressuregaugeandpaintingwithsynthetic enamel paint of approved shade as required. (D.S.R. No-18.20) 209 Providing&fixingofpressureswitchin M.S. pipe line including connectionetc. as required. (D.S.R. No-18.22) 210 Providingandfixinginpositionthe industrialtypepressuregaugeswithgun metal / brass valves complete as required. (D.S.R. No-16.8) 211 ELECTRICAL WORK - SUB- STATION 212 H. T. SYSTEM630KVA 11/0.433KV CSS 213 Supply, receiving, storing, inspection, handling, assembling, installation in correct aligned position,effecting proper connections, testing and commissioning of Outdoor type package type substation with continuous rating DYn11 Copper Wounded VCC-Cast Resin Dry Type Transformer with Off load tap links of +5% to - 5% @2.5% with WTI scanner. Class of Insulation: H, Temperature rise limits of 115 deg.C. Impedance of 5%(Subject to IS Tol.) with WTI scanner. MAKES- ABB/SIEMENS/GE (AR) 214 D.G. SET-1 320KVA-D.G. SET, Supply, installation, testing & commissioning of 3- phase, 415 volt, 1500 RPM, 50 HZ, Diesel generator set with prime rating capacity of 320KVA at 0.8 pf lagging diesel engine alternator set mounted on common base frame in outdoor type acoustic enclosure,battery, batter charger, return fuel cooler, anti vibration mounting pads including residential silencer, engine alternator,safeties with accessories as per specification complete as required. Diesel engine shall conform to IS:10000 and alternator shall be self excited complete with AVR to IS:4722. (AR) 215 D.G. SET-1 200KVA-D.G. SET, Supply, installation, testing & commissioning of 3- phase, 415 volt, 1500 RPM, 50 HZ, Diesel generator set with prime rating capacity of 200KVA at 0.8 pf lagging diesel engine alternator set mounted on common base frame in outdoor type acoustic enclosure,battery, batter charger, return fuel cooler, anti vibration mounting pads including residential silencer, engine alternator,safeties with accessories as per specification complete as required. Diesel engine shall conform to IS:10000 and alternator shall be self excited complete with AVR to (AR) 216 MAIN SUBSTATION-1 L.T PANEL : Design, Manufacturing, Supply, Commissioning & Testing of Main L.T. Panel Cum DG Synchronizing Panel -D.G. Set shall have AMF,LoadManagement,Synchronization facility through PCC Controller / Synchronizing Relay/PLCandalltheD.G.setchangeover facilitywithgridpower. Thepanel willbe totallyenclosedtypewith,freestanding,floor mounted,indoorduty,dust&verminproof,, front operated, electrical panel fabricated from 2 mmthickM.S.Sheet asperspecifications& drawing laid in this document and will be complete with the main and auxiliary bus bars, multimeter,indicationlamps,CTs,protection MCB, interconnection wiring, earth bus and will bepowder coated finish with 50 micron thickness.The panel shall be as per IEC439 (TTA).System Integrator of ABB(ArTu), Schneider(Prisma), Siemens(Sivako n).Authorizedcertificateandagreementcopy withOEMtobesubmitwhiledrawing approvals through contractor. (AR) 217 500KVAR CAPACITOR PANEL 218 INCOMING 219 1 Nos. 800 Amp TP MDO ACB 50KA (The release should be compatible with Bluetooth) Make : ABB(Emax)/Siemens(3WL)/Schneider(Masterp act NW 6E) (AR) 220 BUSBARS 221 1 Nos. 1000 Amp TPN busbars of aluminiumalloy as per SLD. 222 OUTGOING 223 12 stepped Automatic Power Factor Correctionrelay (APFC relay). 224 MAKES- ABB, EPCOS,SCHNIDER 225 HT CABLE-11KV(E)Supply of 3core standered aluminium conductor XLPE insulated PVC bedded, galvanised flat steel strip armoured cable CONFORMING TO IS 7098 (PART- 2) 2011 11KV grade at a depth of 900mm below ground level over a cushion of 100mm thick fine river sand all around and protected with well burnt bricks on sides and on top put across. The armoring of cable shall be properly connected with earth conductor by clamps etc. 120 sq.mm 3 core (PWD- 506a (F)) 226 supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 1 kV grade as required. 120 sq. mm (AR) 227 supplying and making Outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 kV grade as required. 120 sq. mm (AR) 228 Supply and burring of safe earthing electrode T-39Zn-zinccoated,length3000mm,outerdia 76.3mm x 3.2mm inner pipe 42.4mm x 2.6mm, terminal dia 12mm, coating 80-100 micron filledwithcrystallineconductivemixture (CCM)havinganticorrosiveandconductive property with 50 KGs activated soil (BFC) capable of reducing the soil resistivity with good mixtureofretainingcapacityalongwith30sq.cm C.I. frame with hinged curved and (S.I.No-726D) 229 Supply and laying of 25mmX3mm GI strip from earth electrode directly in the ground as required complete in all respect. (S.I.No-716) 230 Supplyandlayingof1800mmx 900mmx 12mm thick chequered rubber matting of testedquality. (S.I.No-1136) 231 Supply of3.5core and 4 core 1.1 KV LT power cable with solid/stranded compacted aluminium conductor, XLPE insulated colour coaded, Laid up, PVC inner shethed armoured with single layer of galvenized round wire or flat strip and over all ST-2 Grade PVC shethed conforming to IS 7098 (part-1) and ISI marked. 3.5 X 400 sq. mm (PWD 2018 (501T)) 232 As above but for 3.5 X 240 sq. mm (PWD 2018 (501R)) 233 As above but for 3.5 X 120 sq. mm (PWD 2018 (501O)) 234 As above but for 3.5 X 70 sq. mm (PWD 2018 (501M) 235 Supply and fixing of brass nickle plated compression gland for PVC insulated and armoured served shethed, underground cable including rubber ring etc. complete in all respect.The armouring of the cable shall be properly connected with the earth as per 236 As above but for 3.5 X 240 sq. mm (PWD 2018 (503R)) 237 As above but for 3.5 X 120 sq. mm (PWD 2018 (503O)) 238 As above but for 3.5 X 70 sq. mm (PWD 2018 (503M) 239 Supply and fixing of plain or pin type copper tin plated cable socket (lug) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-incharge. 240 As above but for 3.5 X 240 sq. mm (PWD 2018 (504M)) 241 As above but for 3.5 X 120 sq. mm (PWD 2018 (504J)) 242 As above but for 3.5 X 70 sq. mm (PWD 2018 (504H)) 243 Bus-Bar Box Stand Alone Outdoor Type 630A (AR) 244 Bus-Bar Box Stand Alone Outdoor Type 400A (AR) 245 Supplying&fixingstandardshocktreatment chartsinEnglish&Hindidulyframedandcovered with glass. (S.I.No-1134) 246 Providing and fixing H.T. danger notice plate of 250 mm X 200 mm, made of mild steel, at least2mmthick,andvitreousenameledwhiteon bothsides,andwithinscriptioninsinglered colour on front side as required. (DSRNO-2.22) 247 Supplyand erection of ISI marked portable fire extinguishers, wall mounted type, wall brackets completeinallrespects,includingfixingon walls as per the direction of engineer-in-charge (Make:Minimax/RealValue/Firex/Safex).CO2 gas type 6.5 kg cap (S.I.No-1132A) 248 S/F of 410 S.P-.55 ISI & ISO certified S.T. pole 11 meter long grouted with 1:3:6 C.C. in brick ballast includingexcavationbackfillingetc. complete with all labour material T&P including plinth30cmaboveG.L.etc.completeinall respect. (S.I.No-613) 249 S/Concreting of Support (0.268cu.m/pole) (PO 2017 PA) 250 S/Paintingofpolewith2coatofAsianAl paint over one coat of red oxide including cleaning of dust vermin & making good complete in all respect. As per direction of E/I(S.I.No-634) 251 Making suitable earthing ofpole with 2.5mlong 20mmdia G.I. rod with 7/16 SWG G.I. wire as perUPPCLcompleteinallmaterial,labour T&P required for proper completion of work 252 Building Distribution Panel I/C-400 Amp. TPN-1 No 200 Amp.TPN-1Nos, 100 Amp.TPN-2Nos. & 63 mp.TPN-1Nos. (SPO 2017 PA) 253 SERVOKON make 630 KVA, 360 - 460 /400 Volts, 3 Phase, Balanced Type, Oil Immersed, Indoor, Rolling contact type (Linear Technology) Servo Stabilizer including First Filling of Fresh Oil and Standard Fittings & Accessories With Bypass Switch. 254 HIGH MAST & LUMINARIES WORK 255 16M HIGH MAST 256 16 Mtr High Mast totally Hot Dip Galvanized and suitable for wind velocity as per IS:875 Part 3,1987. latest version high mast lighting system along with headVframe, steel wire rope, 4 mm dia, single drum winch, galvanized lantern carriage suitable for 8 luminaire & its CGVboxes & lighting finial, integral type high powered reversible power tool for raising and lowering of latern carriage, gear box coupled with winch & torque limiter, foundation bolt of special steel with nuts, washer, anchor platesVtemplate LED beam flood light luminaire 200 watt, shallow foundation considering of safe soil bearing capacity at site as 10 T/sq mtr, at 2 mtr Depth twin dome aviation obstruction light, heavy gauge hot dipped galvanized lighting finals, feeder panel comprising main incoming switch MCBS, Time switch, contactor, reversing starter and protective system etc. as required and (A.R.) 257 Supply & Erection of 7 mtr Long Octagonal pole with Standard double arm bracket (1 mtr long) made up of 48.3mm dia G.I.pipe bracket suitable for road way LED Luminiares fitting as per attached specification with suitable foundation of cement,concrete 1:3:6 (1 cement:3 coarse sand:6 graded stone aggregate 40mm nominal size) foundation including excavation & refilling. dressing up of the plinth etc including 2 nos 60 watt LED fitting, MCB, Flexible pipe, flexible copper wire, socket etc as required (A.R.) 258 Supply and laying of Double walled Corrugated(DWC) pipes for underground power cable protection with IS:14930 Part-II mark on duly printed at every one meter interval along with the socket/coupler andT joint with IP 67 protection for coupling where ever required.The DWC pipe shall be rodent proof and fire resistant and size of Outer dia 90 mm and Inner dia 76 mm and Excavation of cable trench of 110 cm depth and 30 cm wide, in all kinds of soil and its refilling with the same excavated soft soi (A.R.) 259 Supply and burring of safe earthing electrode T-39Zn-zinccoated,length3000mm,outerdia 76.3mm x 3.2mm inner pipe 42.4mm x 2.6mm, terminal dia 12mm, coating 80-100 micron filledwithcrystallineconductivemixture (CCM)havinganticorrosiveandconductive property with 50 KGs activated soil (BFC) capable of reducing the soil resistivity with good mixtureofretainingcapacityalongwith 30sq.cmC.I.framewithhingedcurvedand masonryhousing. (For electrode terminal to switch board, cost of 25X3 GI strip will be extra Make: As proved in UPPWD and CPRI (S.I.No-726 D) 260 Supply and laying of 25mmX3mm GI strip from earth electrode directly in the ground as required complete in all respect. (S.I.No-716) 261 Automatic Light Panel 40A With Astronomical Switch(PWD SOR ELECT.807H/2018) 262 Supply of3.5core and 4 core 1.1 KV LT power cable with solid/stranded compacted aluminium conductor, XLPE insulated colour coaded, Laid up, PVC inner shethed armoured with single layer of galvenized round wire or flat strip and over all ST-2 Grade PVC shethed conforming to IS 7098 (part-1) and ISI marked. 4 X 16Sqmm (S.I.No-501(i) 263 Supply and fixing of brass nickle plated compression gland for PVC insulated and armoured served shethed, underground cable including rubber ring etc. complete in all respect.The armouring of the cable shall be properly connected with the earth as per direction of Engineer-Incharge. (S.I.No-503A(i) 264 Supply and fixing of plain or pin type copper tin plated cable socket (lug) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-incharge. 16Sqmm (S.I.No-504(D) 265 Planetarium, Auditorium, 3D Cinema & confrence Room 266 Supply, Providing, Fixing of Theatre seating Pop-up Theatre Chair made of Steel structure with pop-up mechanism to be auto fold if not needed, Providing P.P seat & back outer using seat and back P.U mould of high density covered with approved shade fabric cushioning foam should be of 30-32 density, HWD-16inchx16inchx16inch, , chair leg made of 2 mm thick M.S seat. All metal component powder coated with 40-50 microns. Embossed leg is providing for stability & strength of mounting pedestal of leg made of 14-gauge M.S sheet & embossed for heaving strength. The pedestal is to be fixed on floor with 100 mm length split hollow anchor/ fastener by inserting 4 mm dia M.S rod to split out the tails of anchor & griping hardly on the floor. armrest should be made of PVC/Plastic to carry Glass/bottle. Chair shall be for extra ergonomically comfort. Support spring and torsion spring shall be of grade 4454 1981 grade 2. Seat & back cushioned with molded no sagging polyurethane molded foam of special grade: - thickness (1) cushion-130 to 150 mm (2) backrest-80 to 100 mm. Fabric made of heavy duty & best quality cotton -jute mix with minimum synthetic material to give the desired finish. Color should be pre-approved by Engineer-in-charge 267 Supplying, Fitting and Fixing of wall paneling (one side) with 10 mm thick beveled edge polyester fiber board panel over supporting wood framing consisting 2” x 1.5” C.P Teak wood as horizontal members at 600 mm C/C (Max) Gap between wall and 10mm thick polyester wool insulation (25mm thick) whose specification is given below. Shade and texture of Polyester fiber board wall paneling should be got approved by the competent authority. Polyester wool insulation(a)Thickness 25mm,(b)Density 20kg/m3(c)Thermal Conductivity 0.034 w/m.k(d)Acoustic insulation with NRC 0.80(e)Fire retardant(f)Non-toxic and itching free(g)Temperature range 15 to 120 Degree CPolyester Fiber Board Panel(a)Size of each panel- 600 mm x 600 mm(b)Surface finish- Matt (c)Density- 200kg/m3(d)Thickness- 10mm(e)NRC 0.80(f)Fire Rating Euro Class B and ASTM E-84-08Thermal Condectivity-0.030 w/m.k 268 Suppling, laying and fixing of graphic loop pile carpet over an underlay of 6mm foam with adhesive over floor area as detail given bellow:Construction-Graphic loop pile Fibre 100% BCF Olefin Pile weight-550g/m2 ±5%Pile height -4-5 mmBacking-Action BackMake- 269 (PART - B) AUDITORIUM 270 Providing & fixing in position, heavy duty fully upholstered Auditorium chairs 520 mm c to c classroom type. Height of back should be less than 1030 mm with plastic protective cover on back and bottom having teak wood handles. Back to back distance is 1000mm. The auditorium chairs should be of following specifications 1. Powder Coated Heavy duty MS Stand. 2. Individually moulded , ergonomically designed seat and back cushions. 3.Moulded Polyurethane Foam cushion. PU foam density 48 – 52 kgs/cu.mtr 4. Moulded Polyurethane Foam manufactured in certified ISO 9001 facility to ensure consistency in density for longevity .5.Upholstered in Foam laminated stretch sandwich Fabric for clean finish and soft comfortable feel as per the colour & pattern selected by the client.6.Seat and Back should have moulded synthetic protective cover. 7. Wooden or PU armrest 65mm x 20mm - 330mm long . 8.Mounted using Anchor fasteners. 271 Supplying, Fitting and Fixing of wall paneling (one side) with 10 mm thick beveled edge polyester fiber board panel over supporting wood framing consisting 2” x 1.5” C.P Teak wood as horizontal members at 600 mm C/C (Max) Gap between wall and 10mm thick polyester wool insulation (25mm thick) whose specification is given below. Shade and texture of Polyester fiber board wall paneling should be got approved by the competent authority. Polyester wool insulation(a)Thickness 25mm,(b)Density 20kg/m3(c)Thermal Conductivity 0.034 w/m.k(d)Acoustic insulation with NRC 0.80(e)Fire retardant(f)Non-toxic and itching free(g)Temperature range 15 to 120 Degree CPolyester Fiber Board Panel(a)Size of each panel- 600 mm x 600 mm(b)Surface finish- Matt (c)Density- 200kg/m3(d)Thickness- 10mm(e)NRC 0.80(f)Fire Rating Euro Class B and ASTM E-84-08Thermal Condectivity-0.030 w/m.k 272 Suppling, laying and fixing of graphic loop pile carpet over an underlay of 6mm foam with adhesive over floor area as detail given bellow: Construction-Graphic loop pile Fibre 100% BCF Olefin Pile weight-550g/m2 ±5% Pile height -4-5 mm Backing-Action Bac kMake- 273 LCD Projector with screen 274 Sound System 275 Computer 276 Furniture (Other then theatre chair) Podium table (4), Podium(2), stage chair (10) 277 (PART - C) CONFERENCE ROOM 278 Supplying, Fitting and Fixing of wall paneling (one side) with 10 mm thick beveled edge polyester fiber board panel over supporting wood framing consisting 2” x 1.5” C.P Teak wood as horizontal members at 600 mm C/C (Max) Gap between wall and 10mm thick polyester wool insulation (25mm thick) whose specification is given below. Shade and texture of Polyester fiber board wall paneling should be got approved by the competent authority. Polyester wool insulation(a)Thickness 25mm,(b)Density 20kg/m3(c)Thermal Conductivity 0.034 w/m.k(d)Acoustic insulation with NRC 0.80(e)Fire retardant(f)Non-toxic and itching free(g)Temperature range 15 to 120 Degree CPolyester Fiber Board Panel(a)Size of each panel- 600 mm x 600 mm(b)Surface finish- Matt (c)Density- 200kg/m3(d)Thickness- 10mm(e)NRC 0.80(f)Fire Rating Euro Class B and ASTM E-84-08Thermal Condectivity-0.030 w/m.k 279 Suppling, laying and fixing of graphic loop pile carpet over an underlay of 6mm foam with adhesive over floor area as detail given bellow:Construction-Graphic loop pile Fibre 100% BCF OlefinPile weight-550g/m2 ±5%Pile height -4-5 mmBacking-Action BackMake- 280 LCD Projector with screen 281 Conference Sound system (26 Seats) 282 Computer 283 A/V Console 284 Furniture (Other then theatre chair) Conference table (1),chairs(50) 285 (PART - D) 3D CINEMA 286 3D Projector with screen 287 Sound System /3D i-Glass Set/ System 288 Computer 289 HVAC Work 290 Hi-side Equipment 291 VRV/VRF units : 292 Supply, Installation, testing & Commissioningof modular type Variable Refrigerant Flow/ Variable Refrigerant Volume aircooled Outdoor units suitable for cooling and heating, having all hermetically sealed inverter type Scroll Compressor(s), minimum two compressors for above 16HP ODU, microprocessor based Controller, top discharge type condensing unit(s), with R407c/R410a/EQUIVALENT Refrigerant, vibration isolators, with suitable foundation etc. complete as required. The unit shall deliver the rated capacity at 40°C Celcius Ambient Conditions and work even at 56°C ambient temperature without tripping. The unit shall be suitable to work on 380V - 460V , 3Phase, 50Hz AC power supply. The unit shall be filled with first charge of the refrigerant and ready for use as required.- The Outdoors shall be be having 34 Liters suction accumlators. The COP at AHRI conditions shall not be less than 3.9- IEER not less than 6.8 .Unit shall include support stand with two coat of enmel panint as per specification. Offered ODU model shall be with highest possible COP by OEM IncludeLifting, shifting, assemblling &positioning of the equipment comprising of the following and complete as per specification/drawingsand as directed by Engineer In Charge 293 Outdoor Units 294 112 HP (28X4) 295 36 HP (24+12) 296 42 HP (28+14) 297 42 HP (28+14) 298 36 HP (24+12) 299 VRF/VRV INDOOR AC UNIT 300 DUCTABLE UNITS 301 Supply, installation, testing and commissioning of following minimum capacity and external static pressure VRF/VRV ceiling mounted ductable type Indoor unit equipped with washable synthetic media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, corded remote control, outer cabinet, vibration isolators, drain pan, other necessary supports etc., suitable for operation on single phase AC supply 230 V ± 10%, 50 Hz complete as required. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature. 302 22 TR 8800 cfm, Floor mounted ducted unit with Pre filter 303 8 TR 3200 cfm, Ceiling supended mounted ducted unit Pre filter 304 6 TR 2400 cfm, Ceiling supended mounted ducted unit Pre filter 305 VRF/VRV INDOOR AC UNIT (CASSETTES UNITS): 306 Supply,installation,testing and commissioning of following minimum capacity 4-way flowCassette Type Indoor ceiling mounted unit equipped with synthetic washable media prefilter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX Copper coil,electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration isolation, cordless remote control etc., suitable for operation on single phase 230V±10%, 50 Hz AC supply, complete, as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will beat air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature. 307 Capacity:- 4.0 Tr 308 Capacity:- 3.2 Tr 309 Capacity:- 2.8 Tr 310 Capacity:- 2.3 Tr 311 Capacity:- 1.5 Tr (Compact type) 312 Centralised Remote Controller 313 Supply, Installation, testing & Commissioning PC compatible Centralised Remote Controller (CRC) for the Entire Indoor and Outdoor Equipment Configuration for Above systems. CRC shall be compatible on BACnet over IP / Modbus BMS protocol. As per specification/drawingsand as directed by Engineer In Charge. The Controller shall be capable of setting timers for units to turn on/off every defined duration for Working Stand-by systems. 314 Cordless remote 315 Corded Remote 316 Y Joints 317 Supply, installation, testing & commissioning pair of Ref Nut/Y-joints brass for indoor and outdoor units of suitable size as per requirement. As per specification/drawingsand as directed by Engineer In Charge. 318 Installation, Testing and Commissioning of VRV indoor and outdoor unit including Supporting 319 A-Outdoor Units 320 B-Lifting, Shifting and positioning of ODU and ducted units 321 C-Supply and Installation of Iron stand for ODU 322 Supply,installation,testing and commissioning including vaccumization and nitrogen testing of following nominal sizes of soft /hard drawn copper refrigerant piping for VRF /VRV system , complete with fittings , with suitable adjustable ring type hanger supports,jointing/brazingincludingaccessories,insulated withXLPE/class-O closed cell elastomeric nitrile rubber tubular sleeves sections of specified thickness as a given below for suction and liquid lines , all accessories as per specifications etc as required . 323 6.4mmdia(OD)(Softdrawn) with19mmthick insulation 324 9.5mmdia(OD)(Softdrawn)with19mmthick insulation 325 12.7mmdia(OD)(Softdrawn)with 19mm thick insulation 326 15.86mmdia(OD)(Softdrawn)with 19mm thick insulation 327 19mmdia(OD)(Harddrawn)with 19mmthick insulation 328 22.2mmdia(OD)(Harddrawn)with 19mm thick insulation 329 28.5mmdia(OD)(Harddrawn)with 19mmthick insulation 330 31.8mmdia(OD)(Harddrawn)with 19mmthick insulation 331 34.9mmdia(OD)(Harddrawn)with 19mmthick insulation 332 38.1mmdia(OD)(Harddrawn)with 19mmthick insulation 333 41.27mmdia(OD)(Harddrawn)with19mmthick insulation 334 44.45mmdia(OD)(Harddrawn) with19mmthick insulation 335 53.97mmdia(OD)(Harddrawn)with19mmthick insulation 336 SupplyfixingWiringforcircuit/submainwiringalongwithearthwirewiththe followingsizesof FRLS PVC insulatedcopperconductor, single core cable in surface/ recessed medium class 20 mm dia FRLS PVC conduit complete with all accessories, supports as required. 337 2 X 1.0 sqmm with 20 mm dia pvc conduit 338 Supply,installation,testingandcommissioningofG.I rectangular ductwork complete with supports, elbows ampers/splitters/vanes/ hangers/supports /rubbe gaskets and ancialliary items as per approved drawings and specifications of thefollowing sheet thickness.: 339 18 Guage (G.I Duct) 340 20 Guage (G.I Duct) 341 22 Guage (G.I Duct) 342 24 Guage (G.I Duct) 343 Duct Insulation 344 Supplying and fixing of following thickness duly laminated aluminumfoilof matfinishclosedcellNitrilerubber(ClassO) insulation on existing duct after applying suitable adhesive for Nitrilerubber.Thejointsshallbesealedwith50mm wideand3 mmthickselfadhesivenitrilerubbertapeinsulationcompleteas per specifications and as required. 19 mm thickness 345 Duct Accoustic Lining : 346 Supplyandfixingofacousticliningofsupplyairductandplenum with25mm thickresinbondedglasswoolhavingdensityof32 kg/m³, with 25 mm X 25 mm GI section of 1.25 mm thick, at 600 mmcentretocentrecoveredwithReinforcedPlastic tissuepaper and 0.5 mm thick perforated aluminum sheet fixed to inside surface ofductswithcadmiumplatednuts,bolts,stickpins,CPRX compound etc. complete as required and as per specifications. 347 Grilles/Diffusers/Louvers/VCDs/FDs : 348 Supplying & fixing of powder coated extruded aluminiumReturnAirGrills withlouversbutwithoutvolumecontrol dampers complete as required. 349 Supplying, fixing testing commissioning of supply air diffusers of powder coated aluminium with aluminium volume control dampers with anti smudge ring & removable core. 350 Supplying, fixing testing commissioning of Return air diffusers of powder coated aluminium without volume control dampers with anti smudge ring & removable core. 351 Supply,installation,testingandcommissioningofVolumecontrol ductdamper completewithneoprenerubbergaskets, nuts, bolts, screws linkages, flanges etc, as per specifications. 352 Supplying,Fixing,testingandcommissioningoffiredampersin supplyair duct/mainbranchandreturn airpathasandwhere requiredofrequiredsizesi/c controlwiring,thedampershallbe motorizedandspringreturnsoastoclosethe damperinthe eventofpowerfailureautomaticallyandopenthesameincase of power being restored. The spring return action shall be inbuiltmechanismand notexternallymounted.Thedamper shall also be closed in the event of fire signal complete as required and as per specifications. 353 Fire Damper 354 Actuator 355 Drain Piping : 356 Supply,installation,testingandcommissioningofofCPVCpipeshavingthermal stability for condesate water including wrapping of 9mm thick class 0 nitrile rubber insulationwithsuitableadhesivewith all CPVCplainandbrassthreadedfittings including the pipes with clamps 1metre spacing.This including jointing of pipes with onestepCPVCsolventcementandtestingofjointscompleteasperdrgand specifications 357 50 mm dia 358 40 mm dia 359 32 mm dia 360 Supplying and installing following size of perforated Hot DippedGalvanised Ironcabletray(Galvanisationthicknessnot lessthan50microns)withperforation notmorethan17.5%,in convenientsections,joinedwithbends,reducerandallaccessories connectors, suspended from theceilingwithG.I.suspendersincludingG.I.bolts&nuts etc. as required. 361 100 mm width X50 mm depth X1.6 mm Thickness 362 150 mm width X50 mm depth X1.6 mm Thickness 363 300 mm width X50 mm depth X1.6 mm Thickness 364 Control Panelfor VRV/VRF Units : 365 Supply, installation, testing and commissioning of alised floor/wall mounted type made of 2 mm thick steel sheet duly painted for outdoor uses IP65 Protection complete as per thespecifications and drawing and as detailed below : 366 1 no. 630 Amps TPN MCCB incomer with KWH 367 meter, phase indicating lamps with control fuse & toggle switch, voltmeter and selector switch, 368 ammeter with CTs and selector switch 369 1 set 630 Amps triple pole with neutral Al. Bus Bars duly sleeved 370 8 no of 63 Amps MCCB outgoing for VRV OD units 371 4 no of 40 Amps MCCB outgoing for VRV OD units 372 Cable 373 Supply, laying, testing and commissioning of following sizes of XLPE insulated PVC sheathed aluminium/ copper conductor armoured / unarmoured cable of 1.1 KV grade on existing cable tray / surface including saddles, clamps etc. complete as required & approved by the Engineer In Charge. (Tagging to be provided with aluminium strips on both the ends as approved). 374 4 Core 16 Sqmm. Copper . Armd 375 4 Core 10 Sqmm. Copper. Armd 376 4 Core 4 Sqmm. Copper. Armd 377 3 Core 2.5 Sqmm. Copper unarmd 378 Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required 379 SOLAR GRID SYSTEM (25 KW) 380 Supply, Installation, Testing and Commissioning of ongrid Solar Photovoltaic Power Plant conforming to MNRE specifications as amended, consisting of Mono/Poly Crystalline silicon solar cells, net metering facility, necessary protections, earthingmounted on Aluminium/GI structure of suitable strength with followincomponents complete as required:a) Solar Photovoltaic Module of capacity 330 Wp or above, manufactured in India, conforming to IS 14286/IEC 61215, IS/IEC 61730-Part-1, IS/IEC 61730-Part-2. SolaPhotovoltaic Module conversion efficiency shall not be less than 16.5%. PV modules used in solar power plants/ systems must be warranted for their output peak watcapacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years. b) Power Conditioning Unit (PCU) of 350-800 V DC Input voltage range and 400 AC, three phase, 4 wire, 50Hz +/- 2.5 Hz, output voltage suitable to generate AC Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 degree C. The PCU shall adjust the voltage and frequency level to suit the Grid Voltage Frequency. c) Data Monitoring System complete with accessories. d) Fixing of Array junction box & Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable along with glands, lugand other accessories etc. as required. e) Lightning and surge voltage protection. f) Connections & Interconnections by supplying & fixing required size XLPinsulated copper conductor 1.1 kV grade armoured power and control cables between solar modules, main power cable to grid supply PCU unit along witsupplying & fixing of necessary channel/conduit lugs and other accessories etc. as required. 381 Site Campus (PA System) 382 Public announcement system (outdoor & Indoor) 383 JBL AWC82 (All -Weather 8 Compact 2-way Coaxial Loudspeaker)(117199.00 -25% = 87899.25) 384 Crown Xli 3500 (Two- channel Power Amplifier) (165182.00 -25% = 123886.50) 385 Harman DBX DriveRack VENU360 (Loudspeaker Management System) (151388.00 -25% = 113541.00) 386 Audio Technica 49QL (Gooseneck Microphone) + AT86685 (Microphone Base Stand)(27494.00 -25% = 20620.50) 387 1.5 mm Amoured Speaker Cable 388 CCTV & surveillance 389 64 Channel Nvr CPPLUS/Dahuaa 390 C.C.T.V 2 MP IP Camera out Door 391 CCTV 2 MP IP Camera Indoor 392 16 Channel Port POE D. Link/Giga 393 4 U Rack with PDU 394 15 U Rack with PDU 395 Dlink Gigabyte switch 16 channel 396 HDD 8 TB 397 PVC Box 398 Wireless Mouse 399 Cat 6 Cable 305 m length 400 Rj 45 connector 401 LED TV 32 inch 402 Cable AC electric 403 HDMI cable 404 Instalation charge 405 Fire Fighting systems 406 Supply &erection of ISImarked portable fire extinguishers, wall mounted type, wall brackets complete in all respect as per standard item with al accessories,delivery hose&nozzle whereever required, includingfixingonwallsasper the directions of E/I. (MAKE:-CEASE FIRE) 407 CO2 gas type 4.5 kg Capacity (IS:2878) 408 D.C.P. type 5 KG. capacity (ABC) 409 ABC Trolley 25 kg Capacity. 410 ABC Type ceilling Mounted 5 KG. capacity. 411 Supply, erection and testing of ISI markedM.S. pipes (Class C - heavy duty) and specials etc, (as per 1S:1239) for above ground laying for hydrants and sprinkler system including transportation of materials upto the worksite, cutting the pipes to required length, edge preperation, welding, fixing / erection of pipes including specials i.e. bends, tees, reducers, flanges, expansion joints wherever required, washers, nuts, bolts etc. in proper position including all supports at maximum 3 meter spacing by 3 mm thick G.I. hangers / clamps / Tie rod supports with G.I. nuts, bolts, anchor fastner and washer for hydrant / sprinkler piping, jointing by welding, aligning the pipe line, painting with two primer coat by zinc chromate primer and two coats of syntheticenamelfireredcolour, providing tapping for pressure gauges and forother instruments etc. Hydrostatic testing of system as specified, flushing & cleaning bywater etc. complete as perdrawings &direction ofthe Engineer-in-charge.The quotedrates shall also include for making holes in masonry / RCC slab, wail, chases in wall, providing sleeves in RCC wall & slabs with puddle flanges whereever required & making good the same by sealing the opening to original conditions. 412 upto 40mm dia. pipe threaded forged fittings and threaded joints shall be provided and for 50mm dia & above pipes welded joints with MS / malleable iron fittings shall be used.(MAKE : Jindal (Hissar) / Bharat / Indian Tube / Prakash) 413 80 NB 414 100 NB 415 Supply, laying & jointing of IS! marked Mild Steel pipes (class C - heavy duty) (as per IS: 1239) including all fittings i.e. reducer, elbows, tees, flanges, washers, nuts, boltsetc. below ground including transportation of all materials to work site, earth work in excavation in all kinds of soil upto 1.50 meter depth, edge preparation, Jointing by welding, laying the pipes in trenches in proper alignment, providing 150 mm thick fine sand layer above pipe, back filling the trenches in layers of 20 cms, consolidation of each deposited layer, watering, ramming, disposal of surplus earth within a lead of 200 m and as directed, hydrostatic testing of the complete pipe work, providing 1:2:4 concrete thrust blocks of suitable size at all bends, tees and junctions with form works, completing the work in all respect as per drawings & direction of the E/I. 416 The rates will include providing and laying 4 mm thick Pypkote tar based polymeric corrosion arotection tape over two coat of zinc chromate orimer as per manufacturers specs, as directed andasper!S:10221.(MAKE : Jindal (Hissar) / Bharat / Indian Tube Co / Prakash) 150 NB 417 Supply & installation of ISI marked single headed 63 mm dia. gunmetal / Stainless steel Hydrant Valve, 80 mm dia flanged inlet with 63 mm female instantaneous outlet confirming to IS : 5290 on the fire wet riser/down comer, including making 80 NB pipe connection with riser along with 100 mm dia dial pressure gauge of calibration 0-15 kg/sq cm, fixing the landing valves in proper positions, including supply of nuts, bolts, gaskets, caps, chains etc. testing the hydrant and completing the work in all respect as per directions of the Engineer in-charge. (MAKE : Firex / Safex / Minimax / Newage) 418 Supply, fixing in position, testing ISI marked cast iron double flanged sluice valves as per IS: 14846-2000, (PN 1.6 mPa) with SS stem, bolts, nuts, 3 mm thick rubber gaskets including transporting to worksite, Complete as per drawings & directions o! the Engineer-in-charge.(MAKE : Kirloskar /Venus / IVC / Zaloto / Audco). 150MMNB 419 Supply & fixing in position iSl marked cast iron double flanged butterfly valves (PN 1.6 MPa) as per IS:130g5, with disc, shaft, seating rings, internal fastening, nuts, bolts including transporting to worksite, 3 mm thick rubber gaskets etc. including testing, Complete as per drawings & directions of the Engineer-in-charge.(MAKE : Kirloskar /Venus / IVC / SKS / Zaloto / Audco). 100MMNB 420 Supply & fixing in position ISl marked cast iron double flanged dual plate type Non Return Valves (PN 1.6 Mpa) as per IS : 5312, part - I, including transportation to worksite, supply & fixing SS nuts, SS bolts, 3 mm thick rubber gaskets, complete with testing as per direction of the Engineer - in -charge.(MAKE : Kirloskar /Venus / IVC / Zaloto/ Audco). 100 NB 421 Supply, fixing, testing & commissioning of 20 mm bore and 30 meter long hose (high pressure rubber braided hose pipe as per IS:444) and hose reel suitable for 10 kg/sqcm operating pressure for first aid fire fighting conforming to IS : 884, with 180° full swing drum, fixing brackets, shut off gun metal / Stainless steel nozzle, 40 mm dia. hand fever operated isolating ball valve, connecting directly from the riser through 40 mm dia. G.l.pipe with sockets, elbows, nipples etc. including - providing operating instructions on a metal plate and fixing it near hose reel. The system shall be complete in all respects as per drawings and directions of Engineer-in-charge. (MAKE : Dunlop / Goodyear / Newage) 422 Providing gun metal/Stainless steel ISl marked 63 mm. dia. male Instantaneous pattern short branch pipes & 20 mm dia. Nozzle as per IS : 903, suitable for 10 kg/sqcm operating pressure and suitable for interconnections to hose pipe coupling as required. (MAKE : Minimax/Firex/Safex/Newaae) 423 Providing ISI marked RRL (IS : 636, type-A) fire hose pipe 15 meter long and 63 mm dia with ISI marked (IS : 903) gun metal / Stainless steel mate and female coupling bound and rivetted to hose pipes with copper rivets and copper wire complete as required. (MAKE:Jayshree / Newage) 424 Providing & fixing 100 mm dia dial pressure gauge complete in all respects. 425 Supply & installation of cast iron body 2 way 63 mm dia male instantaneous inlet coupling complete with cap and chain for fire brigade connection conforming to IS : 904 and making connection with fire fighting pipe or under ground water tank, completing the work in all respect as per the directions of the Engineer-in-charge. (MAKE: Firex / Safex / Minimax / Newage) 426 Providing and fixing weather proof standard fire hose cabinet (900 mm x 600 mm x 450 mm) outdoor type made of not less than 14 SWG MS sheet having glassed hinged door (5 mm thick clear glass) including necessary locking arrangement with handle for housing hydrant valve, two nos.15 meter long fire hose pipes, branch pipe as required as per drawings, including brackets for mounting accessories, painting (one coat primer and two coat of fire red colour). The cabinet shall be mounted on self standing mounted type MS Angle iron frame as required. The words FIRE HOSE to be painted on the box. 427 Constructing brick masonary chamber 90 x 90 x 120 cm inside with FPS brick work in cement mortar 1:5(1 cement: 5 fine sand) for sluice valve with S.F.R.C. cover and frame (heavy duty HD-20 grade designation), 560 mm internal diameter confirming to IS:12592, total weight of cover and frame to be not less than 182 Kg in cement concrete 1:2:4 and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) necessary excavation, foundation concrete 1:5:10 (1 cement: 5 fine sand : 10 graded stone aggregate 40 mm nominal size) & inside plastering with cement mortar 1:4 (1 cement: 4 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design . 428 Supply & Fixing automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump). (a) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical confirming to IS: 1520. (b) Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horizontal foot mounted type with Class-F insulation, conforming to IS-325. (c) M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required.(d) Suitable cement concrete foundation duly plastered and with anti vibration pads. 900 lpm at 35 m Head 429 Providing and fixing danger notice plate of 200 mm X 150 mm made of mild steei at least 2 mm thick vitreous enamelled, white on both sides and with inscription in signal red colour on front side as required. PWD Miscellaneous Item. 430 providing and fixing of shock treatment chart written in English and Hindi both properly framed and glass covered as required. 431 Providingand layingof ISImarked Aluminium conductor, XLPE insulated, armoured, served, sheathed Cable 1100 V grade with terminal joints by palm or pin type cable sockets (lugs), insulating with tapes, double compression type brass and nickle plated compression glands. On surface, the cable run shall be on MS cable trey or fixed on M.S. clampsetc. of suitablesizeor asdirectedby engineer-in- charge, complete in all respects, in ground the cable shall be laid at a depth of 750 mm from ground Level including a cushion of 75 mm thick. Fine river sand alround, duly protected by bricks on sides and top including excavation and back filling of soil or laid in RCC hume pipe as calledfor. The armouring shall be property connected with the earth conductor by clamps etc. PWD Shedule. 16 sqmm 4 core. 432 Providing, fixing, testing and commissioning of manual call points break glass type housed in 16 SWG sheet steel housing in surface/ recess including making connections with wires complete in all respects and as per specifications. The manual call point should have an indicator, which should blink in stand by condition. 433 Providing, fixing, testing and commissioning of electronic hooters (hooters shall also be able to work as public address system sounders) housed in 16 SWG sheet steel housing suitable for wall / ceiling and surface / recess mounting including making connections with wires complete in all respects and as per specifications. 434 Providing, fixing, testing and commissioning of fire alarm main control and indicating panel, solid state modular card type to monitor all local/zonal control panels on each floor or directly detectors as per the case, puiser, timer for dual stage alarm facility complete with indicators, floor selector switches, stand by SMF battery, battery charger, battery box, connections to building automation system / Fire fighting pump panel etc. including Public Address System complete in all respect and as per specifications and requirements. The panel shall have facility of automatic dialling to 5 telephone numbers in case of alarm. The main control panel should give a distinct visual signal of the isolation of zone from the local indication panel. If all the zones at the local panel are isolated or if the fuse of the LCP gets blown, it should result in an open circuit fault indication at the Main Panel. 12 Zone main control panel. 435 Supply and laying of ISI marked Copper conductor PVCinsulated cable as per IS 1554 PVC sheathed 1100 volts grade.On surface the cable run shall be fixed by Gl clamps etc. of suitable size or on existing cable tray complete in all respect.The armouring of the cable shall be properly connectedwiththe earth conductor including fixing of palm or pin type copper tin plated cable socket (lug) to the cable leads, insulating with tape and makingconnections complete in all respect including supply of clamps, lugs, tape etc. complete upto the satisfaction of E/I. 2x1.5 sq mm armoured 436 Providing, fixing, testing and commissioning of wall / ceiling mounted 240 Volts AC 5 W CFL type illuminated EXIT signs,150 x 400 mm having self glowing letters on its front white sheet with embossed asFIRE EXIT including the cost of builtin rechargeable batteries and battery charger suitable for 30 minute operation complete as required. 437 Providing and fixing SS strainer fabricated out of 1.6 mm thick stainless sheet with 3 mm dia holes with SS flange at the suction pipes of fire pumps. 100 mm dia 438 (a) Optical/Photoelectric type Heat detectors as per IS : 11360 -1985 of photo-optic sensing chamber, 12/24 volt D.C., twin visual alarm indicator Blink in stand by and Steady in alarm (LEDs) complete in all respectswith baseas required. 439 Supply, installation and testing of cylindrical type flanged air vessel tank, 450 mm dia, 2 m long and of 10 mm thick M.S., common for a set of fire pumps including flanged connection, suitable supporting legs etc. The air vessel tank shall be provided with 25 mm dia air release valve, stop cock, safety valve, pressure gauge, 25 mm dia drain valve, suitable pressure switches to operate main and jockey pumps, tested to min 20 KG/cm2 complete including painting with synthetic enamel paint of approved shade with all accessories as per direction of the E/I. 440 Wi-Fi & Communication 441 Wi-fi & Communication System 442 Architectural lights 443 Supply and fixing of 20 Watt LED COB Down light Round cast aluminum body. 444 Supply and fixing of 6 watt landscape/spot light. 445 Supply and fixing 5 watt of profile lights 446 Supply and fixing of 18 watt urban decorative garden LED Bollards light 447 Supply and fixing of 36 watt LED surface mounting panel 600x600mm False ceiling Light. 448 Astronomy & Indian Space Programme Gallery 449 Wall Panelling structure- 600 mm x 600mm horizontal and vertical grid frame made of 50mm x 50mm pine wood battons, upto height 2500mm.6MM water proof ply/acp sheet fixed and nailed with appropriate glue or adhesive. 450 Astronomy & Indian Space Programme themed panels made of laminated, digitally printed, 3D effects and pasted on structure 451 Astronomy & Indian Space Programme themed flooring made of linoleum, aluminium grid automobiles flooring, acrylic flooring as required with theme 452 Illuminated signage, illustrations, and information panels made of led, 3D graphics,and traslite 453 LCD/LED screens monitor 42 and 55 total 454 3D LCD laser projector for projection Mapping aligned and intigration with software and central server 455 Server
Contract Date: May 03, 2025 Contract Value : 11.02 Crore
Local Bodies No of Bidders 2
Uttar Pradesh View Result →
39.
Housing Urban and Rular Development #7276283 AOC
Tender For DEPOSIT-Special Sub Jail, Vythiri-CCTV-Supply and Installation of CCTV at Special Sub Jail, Vythiri, Wayanad-General Electronics Work - CCTV 2 OD223555/2024-2025:Supply, Installation, Testing, and Commissioning of Enterprise Class/ Project series Network (IP) Bullet/Dome type Fixed lens Camera having following specification:- Sensor:-1/2.8 inch CMOS progressive scan or better, Resolution:-5 MP, Lens: 2.8 mm, Fixed Iris, F2.0, No. of streams:-Dual or triple stream, Min. Illumination required: - 0.007 Lux / F2.0 (Color,30 IRE), 0 Lux / F2.0 (IR ON) or better , Electronic Shutter Speed- 1/8 ~ 1/32,000,WDR:-120dB True WDR or better and should support HLC, BLC features, Inbuilt Video Analytics : People Counter, Multi Loitering, Intrusion, Tampering, Smart Motion Detection (SMD), Motion Detection; Event Type:- Video motion detection, Alarm input, Recording notification, Tampering, Event Linkage:- Event notification using digital output, Email and Micro SD card, MAX 4.08 W Power Consumption, Should have Smart IR LEDs with min 40m IR distance, Should support Min 256 GB SD card. Should have IP 66/IP 67 and IK10 certification, Alarm: 1 In and 1out, Audio Compression G.711 u-law / G.726; Power:-DC12V, PoE (IEEE 802.3af) (Class 0), Certifications: UL, CE, FCC and RoHS compliant. The cameras should have ONVIF Profile S/G/T compatibility, Security :- User account and password protection, HTTPS, IP Filter, Digest authentication, TLS1.2 only, Stream encryption, AES128 / 256, SSH / Telnet closed, PCI-DSS compliance, Preferred Make: Honeywell HC35W45R3/HC35WB5R3 or equivalent 3 OD223648/2024-2025:Supply, Installation, Testing, and Commissioning of Enterprise Class/ Project series Network (IP) Bullet/Dome type (Varifocal) Camera having following specification:- Sensor:-1/2.8 inch CMOS progressive scan or better, Resolution:-5 MP ,Lens: 2.7-13.5 mm, DC-Iris,F1.6-F3.3, MFZ or better, No. of streams:-Dual or triple stream,Min. Illumination required: - 0.005 Lux / F1.6 (Color, 30 IRE), 0 Lux /F1.6 (IR ON) or better ,Electronic Shutter Speed- 1/8 ~ 1/32,000 , WDR:-120dB True WDR or better and should support HLC, BLCfeatures, Inbuilt Video Analytics : People Counter, Multi Loitering, Intrusion, Tampering, Smart Motion Detection (SMD), Motion Detection; Event Type:- Video motion detection, Alarm input, Recording notification, Tampering, Event Linkage:- Event notification using digital output, Email and Micro SD card, MAX 6 W Power Consumption, Should have Smart IR LEDs with min 50m IR distance, Should support Min 256 GB SD card. Should have IP 66/IP 67 and IK10 certification, Alarm: 1 In and 1out, Audio Compression G.711 u-law / G.726; Power:-DC12V, PoE (IEEE 802.3af) (Class 0), Certifications: UL, CE, FCC and RoHS compliant. The cameras should have ONVIF Profile S/G/T compatibility, Security: User account and password protection, HTTPS, IP Filter, Digest authentication, TLS1.2 only, Stream encryption, AES128 / 256, SSH / Telnet closed, PCI-DSS compliance, Preferred Make: Honeywell HC35W45R2/HC35WB5R2 or equivalent 4 OD223670/2024-2025:Supply and installation of 32CH NVR with Up to 8 MP (4 K) Ultra HD (UHD) resolution live view and playback, Internal Storage:- 4 (3.5 inch) HDD slots with max 10TB capacity on each, Onvif Compliance: Onvif Profile S, Recording:- H.265 HEVC smart codec/ H.264 Compression, Up to 3840 x 2160 Resolution, 30 fps frame rate, Continuous, Manual, Even recording mode, Main stream: 8 Mbps Sub stream: 4 Mbps Max Pre-Event Recording Buffer Size, 30 s (Max. 60 s) Post-Event Recording Interval, Support main stream and sub stream simultaneous recording, video detection and alarms:- Camera: Camera alarm in, (Smart) motion detection, Video loss, Camera tamper, Intrusion, Multi loitering, Crowd detection System: NVR alarm in/out, Disk failure, Disk full, IP address conflict, Network disconnect, Intrusion, Video recording, Push message to App, Pop up message to monitor, Send email, Buzzer, FTP, PTZ-Preset, Full screen, Camera alarm out, System alarm out, Alarm Input 6, Alarm output 2, 10/100/1000Mbps Ethernet (RJ-45) x 2 Ethernet ports, Edge, Chrome, Firefox, Safari Browsers supported, Certifications: UL, CE, FCC and RoHS compliant, Search Mode :-Time search, Event Search, Video clip, Playback Function:- Regular (play, pause, stop), Play backwards, Next frame, Go back 30 seconds, Go forward 30 seconds, Speed control, Timeline, Timeline scale, Digital zoom, Audio, Snapshot, Back up, Decoding:- H.265/H.264: 3840 X 2160 @ 30 fps (1-CH), 2560 x1920 @ 120 fps (4-CH),1920 X 1080 @ 270 fps (9-CH), 720 X 576 @ 960 fps (32-CH), 3840 x 2160, 1920 x 1080, 1280 x 1024, 1024 x 768 Resolution. Preferred Make: Honeywell HN35320400N or equivalent 5 OD222613/2024-2025:Supply and installation of 10TB HDD suitable for above NVR. Preferred Make: Seagate, WD,Toshiba 6 OD225280/2024-2025:Supply and installation of 43 inch or above 4K Television suitable for working 24x7, WiFi, Bluetooth, 2 HDMI inputs, etc. supplied with all necessary accessories including wall mounting kit . Preferred Make: LG UR801C, Panasonic, Samsung, Sony. 7 OD222616/2024-2025:Supply and installation of wireless mouse kit . Preferred make: Dell, HP, Logitech 8 OD225444/2024-2025:Supply and installation of 3m HDMI cable supporting Full HD resolution, with suitable connectors on both end as required, data rate 10 Gbps or better. Preferred Make: MX MX-4049A or equivalent. 9 OD222618/2024-2025:Supply ,installation Testing and Commissioning of 10-Port Gigabit Managed Switch with 8 x 10/100/1000 BASE -T ports and 2 x SFP ports, Switching capacity: 20 Gbps, Certifications: CE, FCC, UL etc. supplied with all necessary accessories . Preferred Make: D-Link DGS-1210-10 or equivalent 10 OD222614/2024-2025:Supply and Installation of 24 port Rack mountable Smart managed Ethernet Switch with 24 x 10/100/1000BASE-T PoE ports 4 x Gigabit RJ45/SFP Combo ports having 193 W PoE budget, Min 56 Gbpsbandwidth, Min 8K MAC Address table size, should support IEEE 802.1D Spanning TreeProtocol, 100 VLAN Support, VLAN tagging, Port based VLAN, IGMP Snooping , DHCP Client support etc. Certifications: CE, FCC, UL . Preferred Model: D-Link DGS-1210-28P or equivalent 11 OD225298/2024-2025:Supply and installation of UL listed, ETL verified 1U , 24 port Rack mountable Enhanced Modular type unloaded Patch Panel with rear cable organizer made of cold rolled steel, powder coated, front labelling Facility and suitable for RJ 45 CAT 6/CAT6A Keystones and labelling as required. Preferred make: Molex, Honeywell, Commscope,Norden 12 OD225300/2024-2025:Supply, termination, testing, and commissioning of UL Listed, ETL verified CAT 6 Keystone Jack with dust protection, suitable for 22- 24 AWG bare copper conductor,Minimum 500 insertion cycles and 100 reterminations, as per TIA/EIA 568-B colour code conforming to the standards ANSI/TIA-568.2-D , ISO/IEC 11801, IEEE 802.3, ISO/IEC 60332-1,and RoHS Complaint. Preferred make: Molex, Honeywell, Commscope Norden 13 OD222619/2024-2025:Supply, installation, testing, and commissioning of UL Listed, ETL verified 0.5 meter CAT 6 UTP Patch Cordhaving LSZHjacket,24 AWG bare copper conductor UTP 4 pairboth end factory Crimped with modular male plugs with minimum 500 insertion cycles terminiated as per TIA/EIA 568-B colour codeconforming tothe standards ANSI/TIA-568.2 , ISO/IEC 11801, IEEE 802.3, ISO/IEC 60332-1,and RoHS Complaint. Preferred Make: Molex, Commscope, Honeywell, Norden 14 OD225317/2024-2025:Supply and fixing of UL certified 19 inch 6U Rack with Front Glass door and lock and all mounting hardware including Horizontal Cable organizer suitable for 19 inch Rack, 2U standard, 230V 6A Inlet Plug type Indian Round Pin 6 Nos, Power Distribution Unit, 8A Fuse, ,Air circulation module 90CFM. Preferred Make: D-Link, Netrack, Valrack 15 OD222615/2024-2025:Supply and installation of weather proof and water proof 4x4square PVC Junction box for camera. 16 OD222608/2024-2025:Supply and installation of Custom made wall mountableCamera Cage to protect cameras from vandalism as well as accidental damage ,constructed of tough, 9-guage steel wire that is coated with corrosion resistant white polyester ,with necessary accessories. 17 OD222611/2024-2025:Supply and Installation ofBIS Certified 2KVADouble Conversion on line UPS withbuilt in Isolation Transformerhaving the following minimum specifications, 1. Output: 220 V +/-10 %, 50 Hz sine wave 2.Input: 140V to 260V, 50Hz single phase 3. Rating : 5KVA 4. Efficiency : 80% or Higher 5.Protection : Over load, Short circuit, Battery reverse polarity, input voltage below or above the specifiedrange, over discharge and over charge of battery 6. Battery Bank: 2880 VAH with TubularBatteries and stand. Necessary minor electrical works should be carried out by the contractor .Preferred make: Hykon, Numeric or equivalent with Exide or Amaron batteries 18 Cabling 19 OD222622/2024-2025:Supply, drawing. testing and commissioning of UL certified and ETL verified 23 AWG bare copper conductor UTP 4 pair Unarmoured CAT 6 cable with HDPE Insulation Material and LSZH Outer Jacket, conforming to thestandards ANSI/TIA-568.2-D, ISO/IEC 11801, IEEE 802.3, ISO/IEC 60332-1,ISO/IEC 61034-2,ISO/IEC 61754-2,Colour Code as per TIA/EIA 568-B, RoHS Compliant,transmission performance tested upto 500 MHz or better and Insertion Loss/ Attenuation: 33 dB/100m or better at 250 MHzin the existing conduit as required.Preferred make: Molex, Honeywell, Commscope,Norden 20 OD222621/2024-2025:Supply, drawing. testing and commissioning of UL certified and ETL verified23 AWG bare copper conductor UTP 4 pair unarmoured Out DoorAnti-Rodent, anti-termite CAT 6 cablewith HDPE Insulation Material and LSZH Outer Jacketconforming to the standards ANSI/TIA-568-C.2, ISO/IEC 11801, IEEE 802.3, ISO/IEC 60332-1, ISO/IEC 61034-2,ISO/IEC 61754-2,Colour Code Per TIA/EIA 568-B,RoHS Compliant transmission performance tested upto 250 MHz or better and Insertion Loss/ Attenuation:33 dB/100m or better at 250 MHz in the existing conduit as required.Preferred Make: Molex Honeywell,Norden,Commscope 21 1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm 22 1.21.2:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm 23 90.12.12.2:Supply & laying of DWC pipe in ordinary soil 1.2 m below ground level including excavation50/38 mm or nearest size 24 1.17.3:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm
Contract Date: Mar 18, 2025 Contract Value : 7.86 Lakh
Government Departments No of Bidders 1
42.
Petroleum and Natural Gas #5701000 AOC
Bids Are Invited For Efh - Providing Er Vehicle With Driver Mahindra Pick-Up 24X7 For Routine And Break Down Maint.Works At Site..All Details As Per Tech. Doc. , Running Km Of Erv Km Per Month Rates Shall Be Paid On The Basis Of Actual Running Kms.- All Details As Per Technical Spec. , Hiring Of Motor Cycle For Pipe Line Patrolling With Gps Enabled Mobile Devices For Monitoring And..All Details As Per Technical Doc. , Running Km Of Motor Cycle Km Per Month Rates Shall Be Paid On The Basis Of Actual Running Kms.- All Details As Per Technical Spec. , Hiring Of Jcb As Per Site Requirement- All Details As Per Technical Spec. , Hiring Of Hydra - 5 Mt Capacity- All Details As Per Technical Spec. , Hiring Of Hydra - 10 Mt Capacity.- All Details As Per Technical Spec. , Hiring Of Crane - 20 Mt Capacity For - All Details As Per Technical Spec. , Hiring Of Ladder Up To 25 Feets - All Details As Per Technical Spec. , Hiring Of Diesel Generator Set - 15 Kva- All Details As Per Technical Spec. , Hiring Of Dewatering Pump - All Details As Per Technical Spec. , Hiring Of Concrete Rock Breaker - All Details As Per Technical Spec. , Hiring Of Compressor For Flushing And Testing Up To 100 Cfm- All Details As Per Technical Spec. , Hiring Of Tractor And Trolley- All Details As Per Technical Spec. , Pe Fittings For Size Above 63 Mm- All Details As Per Technical Spec. , Pe Fittings For Size Equal To Or Lower Than 63 Mm- All Details As Per Technical Spec. , Pe Valves For Size Higher Than 63 Mm - All Details As Per Technical Spec. , Pe Valves For Size 63 Mm Or Lower- All Details As Per Technical Spec. , Gi Pipes Of Size 0.5 Inch To 1.5 Inch- All Details As Per Technical Spec. , Copper Tube- All Details As Per Technical Spec. , Gi Fittings Of Various Sizes From 0.5 Inch To 1.5 Inch- All Details As Per Technical Spec. , Ss 316 Anaconda- All Details As Per Technical Spec. , Blind Meter Adaptor- Gi Temporary Disconnetion Of Dom. Customers- All Details As Per Technical Spec. , Meter Adapter Brass For G1.6, G-6, G-10, G-16, G-25 Meters- All Details As Per Technical Spec. , Isolation Ball Valve Of Size 1.5 Inch- All Details As Per Technical Spec. , Isolation Ball Valve Of Size 0.75 Inch To 1 Inch- All Details As Per Technical Spec. , Isolation Ball Valve Of Size 0.5 Inch- All Details As Per Technical Spec. , Appliance Valve Of Size 0.25 Inch To 0.5 Inch- All Details As Per Technical Spec. , Ss 316 Tubes Of Size 0.75 Inch And 0.5 Inch - All Details As Per Technical Spec. , Ss Fittings Of Size 0.75 Inch And 0.5 Inch- All Details As Per Technical Spec. , 2 Way And 3 Way Ss Ball Valves Of Size 0.75 Inch And 0.5 Inch- All Details As Per Technical Spec. , 12 Inch Dia. 300 Class- All Details As Per Technical Spec. , 10 Inch Dia. 300 Class- All Details As Per Technical Spec. , 8 Inch Dia. 300 Class- All Details As Per Technical Spec. , 6 Inchdia. 300 Class- All Details As Per Technical Spec. , 4 Inch Dia. 300 Class- All Details As Per Technical Spec. , 4 Inch Dia. 600 Class - All Details As Per Technical Spec. , Supply And Application Of Liquid Epoxy Paint Powercrete R95 - All Details As Per Technical Spec. , 6 Inch Dia. 300 Class- All Details As Per Technical Spec. , 4 Inch Dia.300 Class- All Details As Per Technical Spec. , 12 Inch Dia.- All Details As Per Technical Spec. , 10 Inch Dia.- All Details As Per Technical Spec. , 8 Inch Dia.- All Details As Per Technical Spec. , 6 Inch Dia.- All Details As Per Technical Spec. , 4 Inch Dia.- All Details As Per Technical Spec. , Mdpe Pipe Line Repairing Including Excavation, Leakage Arrest, Jointing And Restoration Of Any Dia Up-To 63 Mm.. All Details As Per Technical Doc. , Mdpe Pipe Line Repairing Including Excavation, Leakage Arrest, Jointing And Restoration Of Any Dia Above 63 Mm ..All Details As Per Technical Doc. , Laying Of Pipe Line Upto 63 Mm Dia By Any Method As Per Instruction Of Eic- All Details As Per Technical Spec. , Laying Of Pipe Line Above 63 Mm Dia By Any Method Without Casing As Per Instruction Of Eic- All Details As Per Technical Spec. , Laying Of Pipe Line Above 63 Mm Dia By Any Method With Casing As Per Instruction Of Eic- All Details As Per Technical Spec. , Laying Of Pipe Line Of Size Upto 63 Mm Dia. By Any Method With Or Without Casing- All Details As Per Technical Spec. , Laying Of Pipe Line Of Size 90 And 125 Mm Dia. By Any Method With Or Without Casing- All Details As Per Technical Spec. , Replacement Of Old Transition Fittings Wirh New Transition Fitting - All Details As Per Technical Spec. , Temporary Disconnection Of Mdpe Service Pipe Line For Existing User- All Details As Per Technical Spec. , Construction Of Pedestal - 300Mm X 300 Mm X 300 Mm- All Details As Per Technical Spec. , Sand Filling In All Type Of Sleeves - 2.5 Nb X 300 Mm - All Details As Per Technical Spec. , Supply Of Reinforced Rubber Hose With Clamps - Upto 1.00 Mtr- All Details As Per Technical Spec. , Supply Of Reinforced Rubber Hose With Clamps - More Than 1.00 Mtr And Upto 1.50 Mtrall Details As Per Technical Spec. , Shifting And Installations Of Drs - Dcu Skids For Weight Upto 5 Tonnes- All Details As Per Technical Spec. , Supply And Installation Of New Canopy Over Air Compressor- All Details As Per Technical Spec. , Cascade Inspection - Maintenance As Per Oem Guidelinesall Details As Per Technical Spec. , Painting Of Piping And Structure - Electrical Pole - Crash Barrier- All Details As Per Technical Spec. , Painting Of Wire Mesh - Fencing- All Details As Per Technical Spec. , Installation Of Ss -304 - 304L - 316 - 316L Tubing Including Bending, Testing And Commissioning With Consumable Such As Teflon Tap Etc For 0.5 Inch..All Details As Per Tech. Doc. , Installation Of Ss-304 - 304L - 316 - 316L Tubing Including Bending, Testing And All Details As Per Tech. Doc. , Supply And Installation Of Warning Tape - Anti- Rodent Tape As Per Owner Spec.- All Details As Per Anti- Rodent Tape As Per Owner Spec.- All Details As Per Technical Spec. , Rcc Route Marker- All Details As Per Technical Spec. , Pole Marker With Foundation- All Details As Per Technical Spec. , Plate Marker- All Details As Per Technical Spec. , Scrapping Of Moss, Blister Etc.Thoroughly From Surface Of Walls With Scrapper - Wire Brush Complete In All Respects..All Details As Per Technical Doc. , Removing Loose Scales, Blisters Etc From Old Painted Steel Or Wooden Surface By Scrapping With Wire Brush Thoroughly..All Details As Per Technical Doc. , Two Coats Including Priming Coat- All Details As Per Technical Spec. , Surface Dressing And Grading Of The Ground Including Removing Vegetation And Leveling The Undulations Up To The Depth Of 15 Cms..All Details As Per Technical Doc. , Housekeeping Works At Cgs - Ms - Drs - Dcu Etc. Including Maintenance Of Grass, Cutting, Trimming, Removing Grass, Dusting , Cleaning Area..All Details As Per Tech. Doc. , 1-3-6 1 Cement-3 Sand- 6 Stone Aggregate 20 Mm Nominal Size.- All Details As Per Technical Spec. , 1-2-4 1 Cement-2 Sand-4 Stone Aggregate 20 Mm Nominal Size.- All Details As Per Technical Spec. , 1-1.5-3 1 Cement- 1.5 Coarse Sand Zone-Iii- 3 Graded Stone Aggregate 20 Mm Nominal Size..All Details As Per Tech. Doc. , 1-2-4 1 Cement-2 Sand- 4 Stone Aggregate 20 Mm Nom. In Foundation And Plinth Excluding Form Work And The Cost Of Reinforcement Bars.. All Details As Per Technical Spec. , In 1- 4 Cement Sand Mortar 1 Cement - 4 Medium Coarse Sand - All Details As Per Technical Spec. , Providing Brick On Edge Flooring With 2Nd Class Brick In Cm 1-4 1 Cement - 4 Sand Including Preparation.. All Details As Per Technical Doc. , C.M. 1-4 1 Cement - 4 Sand- All Details As Per Technical Spec. , Providing And Placing In Position 125 Mm Thick Factory Made Machine Batched And Machine Mixed Precast Rcc Rectangular..All Details As Per Technical Doc. , Supply, Fabrication And Installation Of Steel Work Welded In Built Up Sections - Framed Work, Including Cutting..All Details As Per Technical Doc. , Surface Preparation, Supply And Painting Steel Work With Deluxe Multi Surface Paint To Give An Even Shade. Two Or More Coat Applied At 0.90 Ltr Per10 Sqm..All Details As Per Tech. Doc. , Supplying, Fabricating, Erecting, Placing And Fixing In Position Structural Steel Work Riveted.. All Details As Per Technical Doc. , Providing And Applying 2.5 Mm Thick Road Marking Strips Retro-Reflective Of Specified Shade - Colour Using Hot Thermoplastic..All Details As Per Tech. Doc. , Suppy Of Steel Reinforcement For R.C.C. Work Including Straightening, Cutting, Bending, Placing In Position And Binding All..All Details As Per Tech. Doc. , Excavation In All Types Of Rock Hard - Ordinary -Excavation Work In Rock All Types - Hard - Ordinary By Mechanical..All Details As Per Tech. Doc. , Backfilling, Compaction, Leveling Of Excavated Pit - Trecnch-Backfilling Of The Excavated Pit - Trench By Hydraulic Means Jcb - Manual Means..All Details As Per Tech. Doc. , Supply, Installation Of 6A Dp Mcb In Panels For Use With All Material And Labour As Per Spec.S..All Details As Per Tech. Doc. , Supply, Installation Of 10A Dp Mcb In Panels For Use With All Material And Labour As Per Spec.S..All Details As Per Tech. Doc. , Supply, Installation Of 16A Tpand N Mcb In Panels For Use With All Material And Labour As Per Spec.S..All Details As Per Tech. Doc. , Supply, Installation Of 32A, 4P, Mccb In Panels For Use With All Material And Labour As Per Spec.S..All Details As Per Tech. Doc. , Supply, Laying, Termination, Testing And Commissioning, Restoration Of 1.1Kv, 3Cx 4 Sqmm Al Cable , Xlpe..All Details As Per Tech. Doc. , Supply, Installation, Testing And Commissioning Of Wiring For Light Point With 2.5 Sq. Mm Frls Pvc..All Details As Per Tech. Doc. , Supply, Installation, Testing And Commissioning Of Double Compressed Brass Cable Glands Commissioning Of Double Compressed Brass Cable Glands Flp Gland As Per Requirement Of Sizes Upto 1 Inch- All Details As Per Technical Speci , Supply, Installation, Testing And Commissioning Of Double Compressed Brass Cable Glands Flp Gland As Per Requirement Of Sizes Upto2 Inchall Details As Per Technical Specif , Supply, Installation, Testing And Commissioning Of Area Light Fixtures Flp 110 W Led..All Details As Per Tech. Doc. , Measurement, Testing And Maintenance Of Complete Earth Pit And Grid Resistance On Half Yearly Basis..All Details As Per Tech. Doc. , Supply, Installation And Testing Of Indication Lamp Of Electrical Panels- All Details As Per Technical Spec. , Supply, Installation, Testing, Commissioning Of 6 - 16A, 230 Volt Ac, 5 Pin Switch Socket Assembly..All Details As Per Tech. Doc. , Jointing - Splicing Of Optical Fiber Cable 24 Fibers Including Supply Of Optical Splice Closer With Electronic Marker.- All Details As Per Technical Spec. , Dry Chemical Powder- All Details As Per Technical Spec. , 4.5 Kg Co2 Cylinder- All Details As Per Technical Spec. , 6.8 Kg Co2 Cylinder- All Details As Per Technical Spec. , 10 Kg Dcp Cylinder- All Details As Per Technical Spec. , 75 Kg Dcp Cylinder- All Details As Per Technical Spec. , Rubber Washer For Extinguisher- All Details As Per Technical Spec. , Co2 Safety Valves 155Kgf - Cm2- All Details As Per Technical Spec. , Co2 Safety Pins- All Details As Per Technical Spec. , Isi Marked Discharge Pipe With Horn For 6.5 Kg And 6.8Kg Co2exitinguishers.- All Details As Per Technical Spec. , Rubber Gasket Of Dcp Main Cap- All Details As Per Technical Spec. , Dcp Main Cap Gun Metal Cp- All Details As Per Technical Spec. , Dcp Plunger Pin With Spring- All Details As Per Technical Spec. , Dcp Plunger Top- All Details As Per Technical Spec. , Squeezing Grip Plastic Nozzle- All Details As Per Technical Spec. , Dcp Cylinder Discharge Pipe Of Sufficient Length For 10 Kg Capacity Fire Extinguisher- All Details As Per Technical Spec. , Dcp Cylinder Discharge Pipe Of Sufficient Length For 75 Kg Capacity Fire Extinguisher- All Details As Per Technical Spec. , Spray - Brush Painting Of Fire Bucket Stand With Its Bucket 4-6 Bucketincluding Letter - Number Writing.- All Details As Per Technical Spec. , Spray Painiting Of Fire Extinguishers Of All Sizes Includingletter - Number Writing.- All Details As Per Technical Spec. , Air Filling In Cylinders Of Breathing Apparatus With Transportation- All Details As Per Technical Spec. , Hydraulic Testing Of Co2 Cylinders 2 To 4.5Kg Per Cm2- All Details As Per Technical Spec. , Hydraulic Testing Of Co2 Cylinders 6.8Kg Percm2- All Details As Per Technical Spec. , Hydraulic Testing Of Dcp Cylinders Of All Sizes- All Details As Per Technical Spec. , Supply, Installation, Testing And Commissioning Of Hand Operated Siren Of Range 500M- All Details As Per Technical Spec. , Temperature Gauge With Thermowell Of Range 0 To 60 Deg.C As Per The Technical Data Sheet Attached In Technical Tender. - All Details As Per Technical Spec. , Mechanical - Electrical Technician - Skilled- All Details As Per Technical Spec. , Pe Technician - Skilled- All Details As Per Technical Spec. , Plumber Skilled- All Details As Per Technical Spec. , Helpers Un-Skilled- All Details As Per Technical Spec. , Hse Officer - Highly Skilled- All Details As Per Technical Spec. , Patrolling Man - Skilled- All Details As Per Technical Spec. , Front Desk Executive - Skilled- All Details As Per Technical Spec. , Semi Skilled - Cost Includes Uniform - Ppes - Welfare Charges And Other Expenses - All Details As Per Technical Spec. , Un Skilled Labour - Cost Includes Uniform - Ppes - Welfare Charges And Other Expenses- All Details As Per Technical Spec. , Skilled Labour- All Details As Per Technical Spec. , Providing Additional Manpower On Hourly Rates And When Required And Instructed By Eic On Need Basis. - All When Required And Instructed By Eic On Need Basis. - All Details As Per Technical Spec. Total Quantity : 269103
Contract Date: Ref. Documents Contract Value : 3.25 Crore
Statutory Bodies & Commissions/Committees No of Bidders 7
Uttar Pradesh View Result →
43.
Petroleum and Natural Gas #5659875 AOC
Bids Are Invited For Operation And Maintenance Services With Erv In Bijnour Ga , Bijnor - Providing Er Vehicle With Driver Mahindra Pick-Uptatapick-Up- Equivalent 24X7 For Routine And Break Down Maintenance Works At Sit..All Details As Per Technical Specification , Running Km Of Erv Km Per Month Rates Shall Be Paid On The Basis Of Actual Running Kms...All Details As Per Technical Specification , Hiring Of Motor Cycle For Pipe Line Patrolling With Gps Enabled Mobile Devices For Monitoring And Surveillance And Safety Of Hpcls Pipelines..All Details As Per Technical Specification , Running Km Of Motor Cycle Km Per Month Rates Shall Be Paid On The Basis Of Actual Running Kms...All Details As Per Technical Specification , Hiring Of Jcb As Per Site Requirement..All Details As Per Technical Specification , Hiring Of Hydra - 5 Mt Capacity..All Details As Per Technical Specification , Hiring Of Hydra - 10 Mt Capacity...All Details As Per Technical Specification , Hiring Of Crane - 20 Mt Capacity For ..All Details As Per Technical Specification , Hiring Of Ladder Up To 25 Feets ..All Details As Per Technical Specification , Hiring Of Diesel Generator Set - 15 Kva..All Details As Per Technical Specification , Hiring Of Dewatering Pump ..All Details As Per Technical Specification , Hiring Of Concrete - Rock Breaker ..All Details As Per Technical Specification , Hiring Of Compressor For Flushing And Testing Up To 100 Cfm..All Details As Per Technical Specification , Hiring Of Tractor And Trolley..All Details As Per Technical Specification , Pe Fittings For Size Above 63 Mm..All Details As Per Technical Specification , Pe Fittings For Size Equal To Or Lower Than 63 Mm..All Details As Per Technical Specification , Pe Valves For Size Higher Than 63 Mm ..All Details As Per Technical Specification , Pe Valves For Size 63 Mm Or Lower..All Details As Per Technical Specification , Gi Pipes Of Size 0.5 Inch To 1.5 Inch..All Details As Per Technical Specification , Copper Tube..All Details As Per Technical Specification , Gi Fittings Of Various Sizes From 0.5 Inch To 1.5 Inch..All Details As Per Technical Specification , Ss 316 Anaconda..All Details As Per Technical Specification , Blind Meter Adaptor- Gi Temporary Disconnetion Of Dom. Customers..All Details As Per Technical Specification , Meter Adapter - Brass For G1.6, G-6, G-10, G16, G-25 Meters..All Details As Per Technical Specification , Isolation Ball Valve Of Size 1.5 Inch..All Details As Per Technical Specification , Isolation Ball Valve Of Size 0.75 Inch To 1 Inch..All Details As Per Technical Specification , Isolation Ball Valve Of Size 0.5 Inch..All Details As Per Technical Specification , Appliance Valve Of Size 0.25 Inch To 0.5 Inch..All Details As Per Technical Specification , Ss 316 Tubes Of Size 0.75 Inch And 0.5 Inch ..All Details As Per Technical Specification , Ss Fittings Of Size 0.75 Inch And 0.5 Inch..All Details As Per Technical Specification , 2 Way And 3 Way Ss Ball Valves Of Size 0.75 Inch And 0.5 Inch..All Details As Per Technical Specification , 12 Inch Dia. 300 Class - Supply Of Steel Pipeline Leak Clamp..All Details As Per Technical Specification , 10 Inch Dia. 300 Class - Supply Of Steel Pipeline Leak Clamp..All Details As Per Technical Specification , 8 Inch Dia. 300 Class - Supply Of Steel Pipeline Leak Clamp..All Details As Per Technical Specification , 6 Inchdia. 300 Class - Supply Of Steel Pipeline Leak Clamp..All Details As Per Technical Specification , 4 Inch Dia. 300 Class - Supply Of Steel Pipeline Leak Clamp..All Details As Per Technical Specification , 4 Inch Dia. 600 Class - Supply Of Steel Pipeline Leak Clamp..All Details As Per Technical Specification , Supply And Application Of Liquid Epoxy Paint Powercrete R95 Along With Applicator Pad Kit..All Details As Per Technical Specification , 12 Dia. 300 Class - Fitting And Welding Of Sleeve-..All Details As Per Technical Specification , 10 Dia. 300 Class - Fitting And Welding Of Sleeve-..All Details As Per Technical Specification , 8 Dia. 300 Class - Fitting And Welding Of Sleeve-..All Details As Per Technical Specification , 6 Dia. 300 Class - Fitting And Welding Of Sleeve-..All Details As Per Technical Specification , 4 Dia.300 Class - Fitting And Welding Of Sleeve-..All Details As Per Technical Specification , 12 Inch Dia. Fixing Of Leak Clamp..All Details As Per Technical Specification , 10 Inch Dia. Fixing Of Leak Clamp..All Details As Per Technical Specification , 8 Inch Dia. Fixing Of Leak Clamp..All Details As Per Technical Specification , 6 Inch Dia. Fixing Of Leak Clamp..All Details As Per Technical Specification , 4 Inch Dia. Fixing Of Leak Clamp..All Details As Per Technical Specification , Mdpe Pipe Line Repairing Including Excavation, Leakage Arrest, Jointing And Restoration Of Any Dia Up-To 63 Mm And Below Including Supply A..All Details As Per Technical Specification , Mdpe Pipe Line Repairing Including Excavation, Leakage Arrest, Jointing And Restoration Of Any Dia Above 63 Mm Including Supply And Installa..All Details As Per Technical Specification , Laying Of Pipe Line Upto 63 Mm Dia By Any Method As Per Instruction Of Eic..All Details As Per Technical Specification , Laying Of Pipe Line Above 63 Mm Dia By Any Method Without Casing As Per Instruction Of Eic..All Details As Per Technical Specification , Laying Of Pipe Line Above 63 Mm Dia By Any Method With Casing As Per Instruction Of Eic..All Details As Per Technical Specification , Laying Of Pipe Line Of Size Upto 63 Mm Dia. By Any Method With Or Without Casing..All Details As Per Technical Specification , Laying Of Pipe Line Of Size 90 And 125 Mm Dia. By Any Method With Or Without Casing..All Details As Per Technical Specification , Replacement Of Old Transition Fittings Wirh New Transition Fitting ..All Details As Per Technical Specification , Temporary Disconnection Of Mdpe Service Pipe Line For Existing User..All Disconnection Of Mdpe Service Pipe Line For Existing User..All Details As Per Technical Specification , Construction Of Pedestal - 300Mm X 300 Mm X 300 Mm..All Details As Per Technical Specification , Sand Filling In All Type Of Sleeves - 2.5 Nb X 300 Mm ..All Details As Per Technical Specification , Supply Of Reinforced Rubber Hose With Clamps - Upto 1.00 Mtr..All Details As Per Technical Specification , Supply Of Reinforced Rubber Hose With Clamps - More Than 1.00 Mtr And Upto 1.50 Mtr..All Details As Per Technical Specification , Shifting And Installations Of Drs-Dcu Skids For Weight Upto 5 Tonnes..All Details As Per Technical Specification , Supply And Installation Of New Canopy Over Air Compressor..All Details As Per Technical Specification , Cascade Inspectionmaintenance As Per Oem Guidelines..All Details As Per Technical Specification , Painting Of Piping And Structure - Electrical Pole - Crash Barrier..All Details As Per Technical Specification , Painting Of Wire Mesh - Fencing..All Details As Per Technical Specification , Installation Of Ss -304-304L-316- 316L Tubing Including Bending, Testing And Commissioning With Consumable Such As Teflon Tap Etc For 0.5 I..All Details As Per Technical Specification , Installation Of Ss-304-304L316-316L Tubing Including Bending, Testing And Commissioning With Consumable Such As Teflon Tap Etc For 0.75 I..All Details As Per Technical Specification , Supply And Installation Of Warning Tape - Anti- Rodent Tape As Per Owner Specification..All Details As Per Technical Specification , Rcc Route Marker..All Details As Per Technical Specification , Pole Marker With Foundation..All Details As Per Technical Specification , Plate Marker..All Details As Per Technical Specification , Scrapping Of Moss, Blister Etc.Thoroughly From Surface Of Walls With Scrapper- Wire Brush Complete In All Respects As Per Specifications And ..All Details As Per Technical Specification , Removing Loose Scales, Blisters Etc From Old Painted Steel Or Wooden Surface By Scrapping With Wire Brush Thoroughly And Smoothening The Surf..All Details As Per Technical Specification , Two Coats Including Priming Coat..All Details As Per Technical Specification , Surface Dressing And Grading Of The Ground Including Removing Vegetation And Leveling The Undulations Up To The Depth Of 15 Cms Cutting Andf..All Details As Per Technical Specification , Housekeeping Works At Cgs -Ms-Drs-Dcu Etc. Including Maintenance Of Grass, Cutting, Trimming, Removing Grass, Dusting , Cleaning Area, Veget..All Details As Per Technical Specification , 1-3-6 1 Cement-3 Sand- 6 Stone Aggregate 20 Mm Nominal Size...All Details As Per Technical Specification , 1-2-4 1 Cement-2 Sand-4 Stone Aggregate 20 Mm Nominal Size...All Details As Per Technical Specification , 1-1.5-3 1 Cement- 1.5 Coarse Sand Zone-Iii- 3 Graded Stone Aggregate 20 Mm Nominal Size In Foundation And Plinth Excluding Form Work And The..All Details As Per Technical Specification , 1-2-4 1 Cement-2 Sand- 4 Stone Aggregate 20 Mm Nom. In Foundation And Plinth Excluding Form Work And The Cost Of Reinforcement Bars...All Details As Per Technical Specification , In 1-4 Cement Sand Mortar 1 Cement - 4 Medium Coarse Sand ..All Details As Per Technical Specification , Providing Brick On Edge Flooring With 2Nd Class Brick In Cm 1-4 1 Cement - 4 Sand Including Preparation Of Base Including Filling The Join..All Details As Per Technical Specification , C.M. 1-4 1 Cement - 4 Sand..All Details As Per Technical Specification , Providing And Placing In Position 125 Mm Thick Factory Made Machine Batched And Machine Mixed Precast Rcc Rectangular Covers On Trenches Of ..All Details As Per Technical Specification , Supply, Fabrication And Installation Of Steel Work Welded In Built Up Sections- Framed Work, Including Cutting, Hoisting, Fixing In Position..All Details As Per Technical Specification , Fixing In Position..All Details As Per Technical Specification , Surface Preparation, Supply And Painting Steel Work With Deluxe Multi Surface Paint To Give An Even Shade. Two Or More Coat Applied At 0.90..All Details As Per Technical Specification , Supplying, Fabricating, Erecting, Placing And Fixing In Position Structural Steel Work Riveted, Bolted Or Welded In Built Up Sections, Truss..All Details As Per Technical Specification , Providing And Applying 2.5 Mm Thick Road Marking Strips Retro-Reflective Of Specified Shade- Colour Using Hot Thermoplastic Material By Full..All Details As Per Technical Specification , Suppy Of Steel Reinforcement For R.C.C. Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Upto Pl..All Details As Per Technical Specification , Excavation In All Types Of Rock Hard - Ordinary -Excavation Work In Rock All Types - Hard - Ordinary By Mechanical Means Hydraulic - Pneumat..All Details As Per Technical Specification , Backfilling, Compaction, Leveling Of Excavated Pit - Trecnchbackfilling Of The Excavated Pit-Trench By Hydraulic Means Jcb-Manual Means, So..All Details As Per Technical Specification , Supply, Installation Of 6A Dp Mcb In Panels For Use With All Material And Labour As Per Specifications, Drawings And Instruction Of Enginee..All Details As Per Technical Specification , Supply, Installation Of 10A Dp Mcb In Panels For Use With All Material And Labour As Per Specifications, Drawings And Instruction Of Engine..All Details As Per Technical Specification , Supply, Installation Of 16A Tpand N Mcb In Panels For Use With All Material And Labour As Per Specifications, Drawings And Instruction Of E..All Details As Per Technical Specification , Supply, Installation Of 32A, 4P, Mccb In Panels For Use With All Material And Labour As Per Specifications, Drawings And Instruction Of Engin..All Details As Per Technical Specification , Supply, Laying, Termination, Testing And Commissioning, Restoration Of 1.1Kv, 3Cx 4 Sqmm Al Cable , Xlpe Insulated, Armoured, For Power Cabl..All Details As Per Technical Specification , Supply, Installation, Testing And Commissioning Of Wiring For Light Point With 2.5 Sq. Mm Frls Pvc Insulated Copper Conductor Three Core Ca..All Details As Per Technical Specification , Supply, Installation, Testing And Commissioning Of Double Compressed Brass Cable Glands Flp Gland As Per Requirement Of Sizes Upto 1 Inch..All Details As Per Technical Specification , Supply, Installation, Testing And Commissioning Of Double Compressed Brass Cable Glands Flp Gland As Per Requirement Of Sizes Upto2 Inch..All Details As Per Technical Specification , Supply, Installation, Testing And Commissioning Of Area Light Fixtures Flp 110 W Led Well Glass Fixtures For Mounted On Light Pole, St..All Details As Per Technical Specification , Measurement, Testing And Maintenance Of Complete Earth Pit And Grid Resistance On Half Yearly Basis With Name Plate Including Supply And Ere..All Details As Per Technical Specification , Supply, Installation And Testing Of Indication Lamp Of Electrical Panels..All Details As Per Technical Specification , Supply, Installation, Testing, Commissioning Of 6-16A, 230 Volt Ac, 5 Pin Switch Socket Assembly For Indoor Use With All Material And Labou..All Details As Per Technical Specification , Jointing - Splicing Of Optical Fiber Cable 24 Fibers Including Supply Of Optical Splice Closer With Electronic Marker...All Details As Per Technical Specification , Dry Chemical Powder..All Details As Per Technical Specification , 4.5 Kg Co2 Cylinder..All Details As Per Technical Specification , 6.8 Kg Co2 Cylinder..All Details As Per Technical Specification , 10 Kg Dcp Cylinder..All Details As Per Technical Specification , 75 Kg Dcp Cylinder..All Details As Per Technical Specification , Rubber Washer For Extinguisher..All D Specification , Rubber Washer For Extinguisher..All Details As Per Technical Specification , Co2 Safety Valves 155Kgfcm2..All Details As Per Technical Specification , Co2 Safety Pins..All Details As Per Technical Specification , Isi Marked Discharge Pipe With Horn For 6.5 Kg And 6.8Kg Co2exitinguishers...All Details As Per Technical Specification , Rubber Gasket Of Dcp Main Cap..All Details As Per Technical Specification , Dcp Main Cap Gun Metal Cp..All Details As Per Technical Specification , Dcp Plunger Pin With Spring..All Details As Per Technical Specification , Dcp Plunger Top..All Details As Per Technical Specification , Squeezing Grip Plastic Nozzle..All Details As Per Technical Specification , Dcp Cylinder Discharge Pipe Of Sufficient Length For 10 Kg Capacity Fire Extinguisher..All Details As Per Technical Specification , Dcp Cylinder Discharge Pipe Of Sufficient Length For 75 Kg Capacity Fire Extinguisher..All Details As Per Technical Specification , Spray-Brush Painting Of Fire Bucket Stand With Its Bucket 4-6 Bucketincluding Letter-Number Writing...All Details As Per Technical Specification , Spray Painiting Of Fire Extinguishers Of All Sizes Includingletternumber Writing...All Details As Per Technical Specification , Air Filling In Cylinders Of Breathing Apparatus With Transportation..All Details As Per Technical Specification , Hydraulic Testing Of Co2 Cylinders 2 To 4.5Kg-Cm2..All Details As Per Technical Specification , Hydraulic Testing Of Co2 Cylinders 6.8Kg-Cm2..All Details As Per Technical Specification , Hydraulic Testing Of Dcp Cylinders Of All Sizes..All Details As Per Technical Specification , Supply, Installation, Testing And Commissioning Of Hand Operated Siren Of Range 500M..All Details As Per Technical Specification , Temperature Gauge With Thermowell Of Range 0 To 60 Deg.C As Per The Technical Data Sheet Attached In Technical Tender. ..All Details As Per Technical Specification , Mechanical - Electrical Technician - Skilled..All Details As Per Technical Specification , Pe Technician - Skilled..All Details As Per Technical Specification , Plumber - Skilled..All Details As Per Technical Specification , Helpers - Skilled..All Details As Per Technical Specification , Hse Officer - Skilled..All Details As Per Technical Specification , Patrolling Man - Skilled..All Details As Per Technical Specification , Front Desk Executive - Skilled..All Details As Per Technical Specification , Semi Skilled - Cost Includes Uniform - Ppes- Welfare Charges And Other Expenses..All Details As Per Technical Specification , Un Skilled Labour - Cost Includes Uniform - Ppes- Welfare Charges And Other Expenses..All Details As Per Technical Specification , Skilled Labour..All Details As Per Technical Specification , Providing Additional Manpower On Hourly Rates And When Required And Instructed By Eic On Need Basis. ..All Details As Per Technical Specification Total Quantity : 111963
Contract Date: Ref. Documents Contract Value : 2.40 Crore
Statutory Bodies & Commissions/Committees No of Bidders 8
Uttar Pradesh View Result →
44.
Defence #5650504 AOC
Bids Are Invited For Procurement and Installation of Items for Integrated Communication Network Project - Firewall Appliance , Security Subscription License for 3 years , 10 G Short range Transceivers , 1G Short range Transceivers , Log and Reporting Solution Appliance , License for Log Reporting , Anti Virus 25 endpoints , Anti Virus Server , Domain Controller Server , 24 Port SFP Switch, Cat 6 UTP Cable, 12 Core Single Mode Optical Fibre Cable , Installation and Commissioning - Hardware 1 The Firewall must be hardware appliance with ASIC based Security Processing Processors 2 Should support 12 or more gigabit RJ45 interfaces and 8 or more 1G SFP slots 3 Should have 4 no of 10G SFP+ slots or more 4 Should have 1 console port (RJ45) and 1 or more Number of USB ports 5 Should have internal dual power supply from day one Firewall Performance 6 Should have Firewall throughputs of minimum 20 Gbps or more 7 IPSec VPN throughput should be 10 Gbps or more 8 NGFW throughput should be 3.5 Gbps with enterprise mix traffic real world traffic 9 Threat protection throughput should be 3 Gbps with enterprise mix traffic real world traffic 10 Must support at least 3,000,000 or more concurrent connections 11 Must support at least 250,000 or more new sessions per second processing. 12 Should Support Virtualization (ie Virtual Systems / Virtual Domains). Should be having 10 or more virtual system license from day one Firewall Features 13 Should support both “bridge mode” or transparent mode” apart from the standard NAT mode 14 Should provide NAT functionality, including PAT. Should support NAT 66, NAT 64, Static NAT IPv4 to IPv6 and vice versa and IPv6-IPv4 tunneling or dual stack. 15 Should support IPv4 & IPv6 policies 16 Should have provision to create secure zones / DMZ (ie Multi‐ Zone support) 17 Should support the standards based Multi‐Link aggregation technology (IEEE 802.3ad) to achieve higher bandwidth. 18 Should support VLAN tagging (IEEE 802.1q) in NAT/Route mode 19 Should support Static routing and Dynamic Routing (RIP, OSPF & BGP) 20 Should support Active‐Active/ Clustering as well as Active‐ Passive redundancy. 21 Should support ISP Load balancing/ Link Sharing and Failover 22 Should have SD-WAN feature to choose better link for continuing to achieve a high level of application availability and predictable performance. 23 Proposed Appliance should support native SD WAN features and Necessary licenses, if required, need to be provisioned from day 1. 24 Should support multi-path intelligence based on link quality criteria 25 Should support link performance check based on packet loss, latency & jitter 26 Should support configuring multiple SLA rules 27 Should support application specific rules based on SLA strategy 28 Should support high performance deep packet inspection for application identification and control Authentication 29 Should support User‐Group based Authentication (Identity based Firewalling) & Scheduling 30 Should support authentication servers – RADIUS, LDAP & Active Directory 31 Support for RSA Secure ID or other Token based Products. Should have 2 tokens included for enabling MFA for admin logins VPN 32 Should support protocols such as DES & 3DES, MD5, SHA‐1, SHA‐256 authentication, Diffie‐ Hellman Group 1, Group 2, Group 5, Group 14, Internet Key Exchange (IKE) v1 as well as IKE v2 algorithm, The new encryption standard AES 128, 192 & 256 33 Should support minimum 200 IPSec Site-to-Site and 500 no of IPSec Site-to- Client VPN tunnels. 34 Should have integrated SSL VPN with license for 500 concurrent SSL VPN users from day one 35 Support for Client based VPN is mandatory and support for SSL Web VPN is preferable. 36 Should support Windows, Linux and MAC OS for SSL‐VPN 37 Should support NAT within IPSec/SSL VPN tunnels 38 Should support Stateful failover for both Firewall and VPN sessions. IPS 39 Should have a built‐in Signature and Anomaly based IPS engine on the same unit 40 Should have protection for 10000+ signatures 41 Able to prevent denial of service and distributed Denial of Service attacks. 42 Supports user‐defined signatures (i.e., Custom Signatures) with Regular Expressions. Application Control 43 Should have Application control feature with 3000 or more application signatures 44 Should perform Traffic Shaping based on applications 45 Should control popular IM/P2P, proxy applications regardless of port/protocol Gateway Antivirus 46 The appliance should facilitate embedded anti-virus/ anti-malware support 47 Gateway AV/ Anti-malware should be supported for real‐time detection of viruses and malicious code for HTTP, HTTPS, FTP, SMTP, SMTPS, POP3 and IMAP protocols 48 should also include Botnet filtering and detecting and preventing Botnet command and control traffic 49 Should have configurable policy options. Possible to select traffic to scan for viruses Web Filtering 50 The appliance should facilitate embedded Web Content and URL Filtering feature 51 Web content and URL filtering solution should work independently without the need to integrate with External proxy server. 52 URL database should have 200 million or more URLs under more than 70 categories 53 Should be able to block different categories/sites based on User Authentication. Management, Log & Reporting 54 Firewall should support management through GUI (Web-based) or CLI. 55 Firewall should support logging to multiple syslog servers. 56 Log & Reporting should be a dedicated solution out of the Firewall 57 The log & reporting platform must have a storage of 2 TB 58 The solution should provide comprehensive security event logging, reporting Support 59 OEM should be present in India from at least 3 years and should be proposed with 24x7x365 days TAC support, RMA, software updates and subscription update support. The NGFW should be proposed with 3 years subscription licenses for NGFW, NGIPS, Anti Virus , Anti Spyware, Threat Protection, URL Filtering, as mentioned above from day 1. 60 Bidder has to take care of Installation, commissioning of the NGFW. Bidder has to provide training to the team on NGFW 48 should also include Botnet filtering and detecting and preventing Botnet command and control traffic 49 Should have configurable policy options. Possible to select traffic to scan for viruses Web Filtering 50 The appliance should facilitate embedded Web Content and URL Filtering feature 51 Web content and URL filtering solution should work independently without the need to integrate with External proxy server. 52 URL database should have 200 million or more URLs under more than 70 categories 53 Should be able to block different categories/sites based on User Authentication. Management, Log & Reporting (Log & Reporting Solution Appliance) 54 Firewall should support management through GUI (Web-based) or CLI. 55 Firewall should support logging to multiple syslog servers. 56 Log & Reporting should be a dedicated solution out of the Firewall 57 The log & reporting platform must have a storage of 2 TB 58 The solution should provide comprehensive security event logging, reporting Support. (Licence for Log & Reporting Appliance) 59 OEM should be present in India from at least 3 years and should be proposed with 24x7x365 days TAC support, RMA, software updates and subscription update support. The NGFW should be proposed with 3 years subscription licenses for NGFW, NGIPS, Anti Virus , Anti Spyware, Threat Protection, URL Filtering, as mentioned above from day 1. 60 Bidder has to take care of Installation, commissioning of the NGFW. Bidder has to provide training to the team on NGFW 10G/1G Short Range Tranceivers 61 Protocol Standard 10G/1G Base-SR 62 IEEE Standard 802.3ae 63 Module Type SFP+ 64 Data Link Rate for Ethernet 10G/1G Gbps 65 Transmission Range 300m 66 Operating Temperature 0°C to 70°C Anti-virus Server 67 Chassis: 1U Rack Mountable 68 CPU : One or two numbers of 4th Generation Intel® Xeon® Scalable Processor 16 Cores. 69 Chipset : Intel® C741 Chipset 70 Memory : 32DIMM slots. 32 GB DIMMS scalable upto 8.0 TB using DDR5 Registered DIMM (RDIMM) operating at 4800 MT/s 71 Bus Slots : Server should support upto eight PCI-Express 5.0 x16 slots. Additional two x8 or higher PCIe 5.0 slots 72 BOOT optimized storage : 4 x 2TB SAS HDD RAID 0,1,5 74 HDD Bays : Upto 30 SFF SAS/SATA/SSD/NVMe or Upto 16 LFF SAS/SATA/SSD or Upto 36 1T EDSFF or 18 2T EDSFF (FUTURE) 75 Controller : Server should support one of the below controllers, must support Mixed Mode which combines RAID and HBA mode operation simultaneously : Embedded / PCIe based x16 RAID controller with 8GB Flash backed write cache, supporting RAID 0, 1, 5, 6, 10, 50, 60. Must support mix-and-match SAS, SATA, and NVMe drives to the same controller. Controller must support 6G SATA, 12G SAS, 16G NVMe. or Embedded / PCIe based x16 RAID controller supporting RAID 0, 1, 10. Must support mix-and-match SAS, SATA, and NVMe drives to the same controller. Controller must support 6G SATA, 12G SAS, 16G NVMe. or Embedded / PCIe based RAID controller with 4GB Flash backed write cache supporting RAID 0, 1, 5, 6, 10, 50, 60 s Must support mix-and-match SAS, SATA, and NVMe drives to the same controller. Controller must support 6G SATA, 12G SAS, 16G NVMe. Above mentioned controller must support following : 1. Hardware root of trust and secure encryption and decryption of critical drive data 2. Online Capacity Expansion (OCE) 3. Configurable stripe size up to 1 MB 4. Global and dedicated Hot Spare with Revertible Hot 5. Instant Secure Erase 6. Migrate RAID/Stripe Size 7. Modifying Cache Write Policy 8. Move Logical Drive 9. Re-enable Failed Logical Drive or PCIe based x32 RAID controller with 8GB Flash backed write cache, supporting RAID 0, 1, 5, 6, 10, 50, 60, 1T, 10T supporting up to 32 direct-connected storage devices (SAS/SATA/NVMe). Must support mix-and-match SAS, SATA, and NVMe drives to the same controller. Controller must support 6G SATA, 24G SAS, 16G NVMe. Controller must support following : 1. Expand Logical Drive 2. Instant Secure Erase 3. Migrate RAID/Stripe Size 4. Modifying Cache Write Policy 5. Move Logical Drive 6. Re-enable Failed Logical Drive 76 Networking features : Server should support below networking cards: 1. 1Gb 4-port network adaptors 2. 10Gb 2-port Ethernet adaptor 3. 10GBaseT 2-port Ethernet adaptor 4. 10/25Gb 2-port SFP28 Ethernet adaptor 5. 10/25Gb 4-port SFP28 Ethernet adaptor 6. 100Gb 2-port QSFP28 Ethernet 7. 100Gb 1-port QSFP56 Ethernet 8. 100Gb 2-port QSFP56 Ethernet 9. 200Gb QSFP56 Ethernet Infiniband Options: 100Gb or 200Gb Single or Dual port Adapter 77 Interfaces : Serial - 1 (Optional) USB support with Up to 5 total: 1 front, 2 rear, 2 internal. 1GbE Dedicated management port 78 Power Supply : Should support hot plug redundant low halogen power supplies with minimum 94% efficiency 79 Fans : Redundant hot-plug system fans 80 Industry Standard Compliance : ACPI 6.3 Compliant PCIe 5.0 Compliant WOL Support Microsoft® Logo certifications PXE Support Energy Star SMBIOS 3.2 UEFI 2.7 Redfish API IPMI 2.0 Secure Digital 4.0 Advanced Encryption Standard (AES) Triple Data Encrytion Standard (3DES) SNMP v3 TLS 1.2 DMTF Systems Management Architecture for Server Hardware Command Line Protocol (SMASH CLP) Active Directory v1.0 ASHRAE A3/A4 81 System Security: UEFI Secure Boot and Secure Start support Tamper-free updates - components digitally signed and verified Immutable Silicon Root of Trust Ability to rollback firmware FIPS 140-2 validation Secure erase of NAND/User data Common Criteria certification TPM (Trusted Platform Module) 1.2 option Configurable for PCI DSS compliance TPM (Trusted Platform Module) 2.0 option Advanced Encryption Standard (AES) and Triple Data Encryption Standard (3DES) on browser Bezel Locking Kit option Support for Commercial National Security Algorithms (CNSA) Chassis Intrusion detection option Secure Recovery - recover critical firmware to known good state on detection of compromised firmware 82 Operating Systems and Virtualization Software Support : Windows Server. Red Hat Enterprise Linux (RHEL) SUSE Linux Enterprise Server (SLES) VMware ESXi. Canonical Ubuntu Oracle Linux and Oracle VM Citrix 83 Provisioning : 1. Should support tool to provision server using RESTful API to discover and deploy servers at scale 2, Provision one to many servers using own scripts to discover and deploy with Scripting Tool (STK) for Windows and Linux or Scripting Tools for Windows PowerShell 84 Firmware security : 1. For firmware security, system should support remote management chip creating a fingerprint in the silicon, preventing servers from booting up unless the firmware matches the fingerprint. This feature should be immutable 2. Should maintain repository for firmware and drivers recipes to aid rollback or patching of compromised firmware. Should also store Factory Recovery recipe preloaded to rollback to factory tested secured firmware 85 Embedded Remote Management and firmware security : 1. System remote management should support browser based graphical remote console along with Virtual Power button, remote boot using USB/CD/DVD Drive. It should be capable of offering upgrade of software and patches from a remote client using Media/image/folder; It should support server power capping and historical reporting and should have support for multifactor authentication 2. Server should have dedicated 1Gbps remote management port 3. Server should have storage space earmarked to be used as a repository for firmware, drivers and software components. The components can be organized in to install sets and can be used to rollback/patch faulty firmware 4. Server should support agentless management using the out-of-band remote management port 5. The server should support monitoring and recording changes in the server hardware and system configuration. It assists in diagnosing problems and delivering rapid resolution when system failures occur 6. Two factor Authentication 7. Local or Directory-based user accounts with Role based access control 8. Remote console sharing upto 6 users simultaneously during pre-OS and OS runtime operation, Console replay - Console Replay captures and stores for replay the console video during a servers last major fault or boot sequence. Microsoft Terminal Services Integration, 128 bit SSL encryption and Secure Shell Version 2 support.Should provide support for AES and 3DES on browser.Should provide remote firmware update functionality.Should provide support for Java free graphical remote console. 9. Should support managing multiple servers as one via Group Power Control Group Power Capping Group Firmware Update Group Configuration Group Virtual Media and Encrypted Virtual Media Group License Activation 10. Should support RESTful API integration 11. System should support embedded remote support to transmit hardware events directly to OEM or an authorized partner for automated phone home support 12. Server should have security dashboard : displaying the status of important security features, the Overall Security Status for the system, and the current configuration for the Security State and Server Configuration Lock features. 13. One-button Secure Erase designed to decommission/repurpose servers 14. NVMe wear level display 15. Workload Performance Advisor - Provides server tuning recommendations to improve server performance 86 Server Management : Software should support dashboard view to quickly scan the managed resources to assess the overall health of the data center. It should provide an at-a-glance visual health summary of the resources user is authorized to view. 87 The Dashboard minimum should display a health summary of the following: • Server Profiles • Server Hardware • Appliance alerts 88 The Systems Management software should provide Role-based access control 89 Zero Touch Provisioning (ZTP) using SSDP with remote access 90 Management software should support integration with popular virtualization platform management software like Vmware vCenter & vRealize Operations, and Microsoft System Center & Admin Center 91 Should help provide proactive notification of actual or impending component failure alerts on critical components like CPU, Memory and HDD. 92 Should provide an online portal that can be accesible from anywhere. The portal should provide one stop, online access to the product, support information and provide information to track warranties, support contrats and status. The Portal should also provide a personalised dashboard to monitor device heath, hardware events, contract and warranty status. Should provide a visual status of individual devices and device groups. The Portal should be available on premise (at our location - console based) or off premise (in the cloud). 93 Should help to proactively identify out-of-date BIOS, drivers, and Server Management agents and enable the remote update of system software/firmware components. 94 Should have dashboard for firmware baselines while performing minimum required firmware checks and highlighting out-of-compliance devices for updates with the selected firmware baseline 95 The Server Management Software should be of the same brand as of the server supplier. 96 Cloud Enabled Monitoring and Management : 1. Secure connection from customer sites to HPE cloud service 2. Unified Identity & Access Management 3. Manages and controls servers regardless of physical location 4. Subscription-based entitlement 5. Efficient Device Onboarding 6. Firmware Update Awareness with Intelligent delta-only based updates 7. Set Group firmware Baseline and Compliance monitoring and notification 8. Group based firmware management that can be scheduled or on-demand 9. Remote Site management with low bandwidth/high latency network connectivity 10. Role-based access and views for managed customer environments 11. GUI and Rest APIs for core features Anti-Virus 97 The solution must utilize Client Server architecture where Central Endpoint Management Console can be used for creating and distributing policies. Central Endpoint Management Console should be able to create, manage and monitor all the endpoints across the organization centrally. Central Endpoint Management Server should utilize On-Premise architecture and no SaaS / Cloud model. 98 The solution should support All-in-One Centralized Management — deploy, manage and monitor Clients on-premise or off-premise. Management Server console also should help to provide real-time control and visibility into endpoints when they are either on or off corporate networks. 99 Solution should support integration and synchronization with Microsoft Active Directory (AD) 100 Solution should support installing and managing agents on Microsoft Windows 10 / 11 & Windows Server 2012+, Mac OS 11+ 101 Solution should support Endpoint Protection features of Anti-Malware, Anti-Exploit, Web Filter, Application Firewall, Vulnerability Assessment and Management, Software Inventory Management and USB Control . 102 Solution should be able to Block Access to Malicious Websites, Scan Compressed Files, Scan Network Files, Scan Removable Media on Insertion, Scan Email attachments. 103 Solution should support easy creation of security profiles with customizable features such as Antimalware, Exploit Prevention, Application Firewall, Web Filter, USB Control etc. applied to specific set of devices or for all devices. 104 The management server should support creation of Custom Installer Packages with included Security Profiles to help simplify deployment and management of endpoints from a single console. 105 Custom Installer Package should be available from web-link of Management Console in MSI / EXE / DMG packages. 106 The centralized management console should be web-based and should support Role Based Access (RBAC). 107 Solution must offer comprehensive client/server security by protecting enterprise networks from Viruses, Trojans, Worms, Network Viruses, Spyware and Rootkits. 108 Solution must provide real-time on-access scanning for file systems to prevent or stop malicious code execution. 109 The proposed solution should provide tamper protection to prevent end-users or malicious actors from disabling the endpoint protection software. 110 Tamper protection should support configurable password in case emergency override is required. 111 The proposed system shall be able to querie a real time database of over 50 million+ rated websites categorized into 70+ unique content categories. 112 Should support Endpoint Quarantine to quickly disconnect a compromised endpoint from the network and stop it from infecting other assets. 113 Solution should be able to detect and prevent communication patterns used by Bots like information about botnet family. 114 Solution should be able to block traffic between infected host and remote C&C operator but at the same time allow traffic to legitimate destinations. 115 The solution should detect and prevent various exploit techniques providing protection against memory-based attacks. 116 Solution should monitor behaviour of applications like Web Browsers (IE, Chrome, Firefox, Opera), Java/Flash plug-ins, Microsoft Office applications, and PDF reader as part of anti-exploit feature. 117 Endpoint solution should have vulnerability scanning feature to check for known vulnerabilities in the endpoints. 118 The solution must support creation of exclusions / exceptions from Central Console and pushing them to the endpoints. It should not require creation of exclusions on individual endpoints. 119 The solution must be provided for 50 endpoint licenses including software updates, upgrades and technical support for 3 years. 120 Bidder has to take care of Installation, commissioning of the End point Agents. Bidder has to provide training to the team. Domain Controller Server 121 Chassis : 1U Rack Mountable 123 CPU : One or two numbers of 4th Generation Intel® Xeon® Scalable Processor 16 Cores. 124 Chipset : Intel® C741 Chipset 125 Memory : 32DIMM slots. 64 GB DIMMS scalable upto 8.0 TB using DDR5 Registered DIMM (RDIMM) operating at 4800 MT/s 126 Bus Slots : Server should support upto eight PCI-Express 5.0 x16 slots. Additional two x8 or higher PCIe 5.0 slots 127 BOOT optimized storage : 4 x 2TB SAS HDD RAID 0,1,5 128 HDD Bays : Upto 30 SFF SAS/SATA/SSD/NVMe or Upto 16 LFF SAS/SATA/SSD or Upto 36 1T EDSFF or 18 2T EDSFF (FUTURE) 129 Controller : Server should support one of the below controllers, must support Mixed Mode which combines RAID and HBA mode operation simultaneously : Embedded / PCIe based x16 RAID controller with 8GB Flash backed write cache, supporting RAID 0, 1, 5, 6, 10, 50, 60. Must support mix-and-match SAS, SATA, and NVMe drives to the same controller. Controller must support 6G SATA, 12G SAS, 16G NVMe. or Embedded / PCIe based x16 RAID controller supporting RAID 0, 1, 10. Must support mix-and-match SAS, SATA, and NVMe drives to the same controller. Controller must support 6G SATA, 12G SAS, 16G NVMe. or Embedded / PCIe based RAID controller with 4GB Flash backed write cache supporting RAID 0, 1, 5, 6, 10, 50, 60 s Must support mix-and-match SAS, SATA, and NVMe drives to the same controller. Controller must support 6G SATA, 12G SAS, 16G NVMe. Above mentioned controller must support following : 1. Hardware root of trust and secure encryption and decryption of critical drive data 2. Online Capacity Expansion (OCE) 3. Configurable stripe size up to 1 MB 4. Global and dedicated Hot Spare with Revertible Hot 5. Instant Secure Erase 6. Migrate RAID/Stripe Size 7. Modifying Cache Write Policy 8. Move Logical Drive 9. Re-enable Failed Logical Drive or PCIe based x32 RAID controller with 8GB Flash backed write cache, supporting RAID 0, 1, 5, 6, 10, 50, 60, 1T, 10T supporting up to 32 direct-connected storage devices (SAS/SATA/NVMe). Must support mix-and-match SAS, SATA, and NVMe drives to the same controller. Controller must support 6G SATA, 24G SAS, 16G NVMe. Controller must support following : 1. Expand Logical Drive 2. Instant Secure Erase 3. Migrate RAID/Stripe Size 4. Modifying Cache Write Policy 5. Move Logical Drive 6. Re-enable Failed Logical Drive 130 Networking features : Server should support below networking cards: 1. 1Gb 4-port network adaptors 2. 10Gb 2-port Ethernet adaptor 3. 10GBaseT 2-port Ethernet adaptor 4. 10/25Gb 2-port SFP28 Ethernet adaptor 5. 10/25Gb 4-port SFP28 Ethernet adaptor 6. 100Gb 2-port QSFP28 Ethernet 7. 100Gb 1-port QSFP56 Ethernet 8. 100Gb 2-port QSFP56 Ethernet 9. 200Gb QSFP56 Ethernet Infiniband Options: 100Gb or 200Gb Single or Dual port Adapter 131 Interfaces : Serial - 1 (Optional) USB support with Up to 5 total: 1 front, 2 rear, 2 internal. 1GbE Dedicated management port 132 Power Supply : Should support hot plug redundant low halogen power supplies with minimum 94% efficiency 133 Fans : Redundant hot-plug system fans 134 Industry Standard Compliance : ACPI 6.3 Compliant PCIe 5.0 Compliant WOL Support Microsoft® Logo certifications PXE Support Energy Star SMBIOS 3.2 UEFI 2.7 Redfish API IPMI 2.0 Secure Digital 4.0 Advanced Encryption Standard (AES) Triple Data Encrytion Standard (3DES) SNMP v3 TLS 1.2 DMTF Systems Management Architecture for Server Hardware Command Line Protocol (SMASH CLP) Active Directory v1.0 ASHRAE A3/A4 135 System Security : UEFI Secure Boot and Secure Start support Tamper-free updates - components digitally signed and verified Immutable Silicon Root of Trust Ability to rollback firmware FIPS 140-2 validation Secure erase of NAND/User data Common Criteria certification TPM (Trusted Platform Module) 1.2 option Configurable for PCI DSS compliance TPM (Trusted Platform Module) 2.0 option Advanced Encryption Standard (AES) and Triple Data Encryption Standard (3DES) on browser Bezel Locking Kit option Support for Commercial National Security Algorithms (CNSA) Chassis Intrusion detection option Secure Recovery - recover critical firmware to known good state on detection of compromised firmware 136 Operating Systems and Virtualization Software Support : Windows Server. Red Hat Enterprise Linux (RHEL) SUSE Linux Enterprise Server (SLES) VMware ESXi. Canonical Ubuntu Oracle Linux and Oracle VM Citrix 137 Provisioning : 1. Should support tool to provision server using RESTful API to discover and deploy servers at scale 2, Provision one to many servers using own scripts to discover and deploy with Scripting Tool (STK) for Windows and Linux or Scripting Tools for Windows PowerShell 138 Firmware security : 1. For firmware security, system should support remote management chip creating a fingerprint in the silicon, preventing servers from booting up unless the firmware matches the fingerprint. This feature should be immutable 2. Should maintain repository for firmware and drivers recipes to aid rollback or patching of compromised firmware. Should also store Factory Recovery recipe preloaded to rollback to factory tested secured firmware 139 Embedded Remote Management and firmware security : 1. System remote management should support browser based graphical remote console along with Virtual Power button, remote boot using USB/CD/DVD Drive. It should be capable of offering upgrade of software and patches from a remote client using Media/image/folder; It should support server power capping and historical reporting and should have support for multifactor authentication 2. Server should have dedicated 1Gbps remote management port 3. Server should have storage space earmarked to be used as a repository for firmware, drivers and software components. The components can be organized in to install sets and can be used to rollback/patch faulty firmware 4. Server should support agentless management using the out-of-band remote management port 5. The server should support monitoring and recording changes in the server hardware and system configuration. It assists in diagnosing problems and delivering rapid resolution when system failures occur 6. Two factor Authentication 7. Local or Directory-based user accounts with Role based access control 8. Remote console sharing upto 6 users simultaneously during pre-OS and OS runtime operation, Console replay - Console Replay captures and stores for replay the console video during a servers last major fault or boot sequence. Microsoft Terminal Services Integration, 128 bit SSL encryption and Secure Shell Version 2 support.Should provide support for AES and 3DES on browser.Should provide remote firmware update functionality.Should provide support for Java free graphical remote console. 9. Should support managing multiple servers as one via Group Power Control Group Power Capping Group Firmware Update Group Configuration Group Virtual Media and Encrypted Virtual Media Group License Activation 10. Should support RESTful API integration 11. System should support embedded remote support to transmit hardware events directly to OEM or an authorized partner for automated phone home support 12. Server should have security dashboard : displaying the status of important security features, the Overall Security Status for the system, and the current configuration for the Security State and Server Configuration Lock features. 13. One-button Secure Erase designed to decommission/repurpose servers 14. NVMe wear level display 15. Workload Performance Advisor - Provides server tuning recommendations to improve server performance 140 Server Management : Software should support dashboard view to quickly scan the managed resources to assess the overall health of the data center. It should provide an at-a-glance visual health summary of the resources user is authorized to view. 141 The Dashboard minimum should display a health summary of the following: • Server Profiles • Server Hardware • Appliance alerts 143 The Systems Management software should provide Role-based access control 144 Zero Touch Provisioning (ZTP) using SSDP with remote access 145 Management software should support integration with popular virtualization platform management software like Vmware vCenter & vRealize Operations, and Microsoft System Center & Admin Center 146 Should help provide proactive notification of actual or impending component failure alerts on critical components like CPU, Memory and HDD. 147 Should provide an online portal that can be accesible from anywhere. The portal should provide one stop, online access to the product, support information and provide information to track warranties, support contrats and status. The Portal should also provide a personalised dashboard to monitor device heath, hardware events, contract and warranty status. Should provide a visual status of individual devices and device groups. The Portal should be available on premise (at our location - console based) or off premise (in the cloud). 148 Should help to proactively identify out-of-date BIOS, drivers, and Server Management agents and enable the remote update of system software/firmware components. 149 Should have dashboard for firmware baselines while performing minimum required firmware checks and highlighting out-of-compliance devices for updates with the selected firmware baseline 150 The Server Management Software should be of the same brand as of the server supplier. 160 Cloud Enabled Monitoring and Management : 1. Secure connection from customer sites to HPE cloud service 2. Unified Identity & Access Management 3. Manages and controls servers regardless of physical location 4. Subscription-based entitlement 5. Efficient Device Onboarding 6. Firmware Update Awareness with Intelligent delta-only based updates 7. Set Group firmware Baseline and Compliance monitoring and notification 8. Group based firmware management that can be scheduled or on-demand 9. Remote Site management with low bandwidth/high latency network connectivity 10. Role-based access and views for managed customer environments 11. GUI and Rest APIs for core features 24 PORT SFP SWITCH 161 The switch should have minimum 24 x ports 10/100/1000 BASE-T ports and 4 x 1/10 SFP ports. 162 The switch should have 128 Gbps of Switching Capacity 163 Switch shall have minimum 512MB SDRAM, 256MB flash and 1.5MB Packet buffer size 164 The Switch should support 8000 MAC address 165 Switch shall support Dual stack (IPv4 and IPv6) transitions, MLD snooping, IPv6 ACL/QoS 166 The Switch should support Uni-directional Link Detection (UDLD) or equivalent feature 167 Switch should support IEEE 802.1Q VLANs with 4096 VLANs simultaneously, GVRP 168 The Switch should support Zero-Touch Provisioning (ZTP) or equivalent technology support. 169 Switch shall support sFlow/ Netflow or equivalent 170 The Switch should have support Rapid Per-VLAN Spanning Tree (RPVST+)/PVRST+, RSTP, MSTP 171 The Switch should have support for Static IP routing 172 Switch shall have support for CLI, GUI, SSHv2, SSL and SNMP v3 173 Proposed switches, transceivers and wireless equipment should from same OEM for interoperability and ease of management. 174 3 -year NBD support should be provided directly from OEM Cat 6 UTP Cable 175 23 AWG Annealed bare solid copper, CAT-6 UTP Cable 176 PAIRS Color code: Blue / White-Blue, Orange / White-Orange Green / White-Green, Brown / White – Brown 177 Type Of Conductors: 4 pair 23 AWG Conductors and star separator. 178 Cable Pull Tension Thread & FR Grade PVC 179 Jacket : Fire Retardant PVC 180 Frequency : Characterized to 600 MHz 181 Standard length: 305 Mtrs (1000 ft.) 182 Outer Sheath Colour : Blue 183 Standards: UL Listed, ETL Tested & Verified 184 Gigabit Requirements’: Should meet or exceed Gigabit Ethernet requirements at 100 Mtrs. 185 Insulation : Polyethylene 186 Star Separator should be provided for the 4 Pairs 187 Jacket : Flame Retardant PVC 188 Performance Characteristics- Category 6 EIA/TIA 568.C.2 189 ETL Verified up to 400 MHz 190 ROHS Complaint 191 25 years Warranty 12 Core Single Mode Optical Fibre Cable 192 Optical fibres in water blocked loose tube, taped, corrugated steel tape armoured (STA) polyethylene (HDPE) outer sheathed embedded with two steel wires on the periphery. The cables are with UV Stabilized PE Jacket and protected from Rodent attacks. 193 Fiber Type: Complying to ISO/IEC 11801, EN50173, ANSI/TIA 568-C.3, Telcordia GR-20; suitable for use in indoor / outdoor ducts, direct burial and backbone cabling. 194 Construction type : Single Mode, 9/125 micron primary coated buffers, OS2 (IEC 60793-2-50, B1.3 and ITU T G652.d). Shall be manufactured using Vapor Axial Deposition technology. 195 No of fibres: 3.0/2.0 mm nominal OD/ID 196 Fibre colour sequence : 12 Blue, Orange, Green, Brown, Slate (Grey), White, Red, Black, Yellow, Violet, Pink, Aqua 197 Water Blocking 198 Core Wrapping : Thixotropic Gel (Tube) Petroleum Jelly (Interstices) 199 Armouring: Polyethylene Terephthalate Corrugated Steel Tape Armour (ECCS Tape) 200 Peripheral Strength Member Thickness > 0.125mm 201 Ripcord : Two Steel wires (0.9 mm dia) 202 Standards : The cable should be anti-termite and antirodent. 203 Complying to ISO/IEC 11801 2nd Edition, type OS1/OS2; AS/ACIF S008; AS/NZS 3080 ; TIA/EIA 568.C.3; IEC-60793-1, 60793-2 204 Mechanical characteristics : EN50173, ANSI/TIA 568-C.3, Telcordia GR-20; suitable for use in indoor / outdoor ducts, direct burial and backbone cabling 205 Mass (Nominal): 9.0 MM8 0 kg/km 206 Cable length2 km ± 10% 207 Max. Bending Radius (during installation) 20 X Overall diameter 208 Max. Bending Radius (during full load): 10 X Overall diameter 209 Max. Tensile Strength-Short Term1500N 210 Max. Crush Resistance-Short Term: 2000N/10 cm 211 Operating Temperature range-40°C ±70°C 212 Optical characteristics Core Diameter @ 1310nm 213 RoHS Complaint Total Quantity : 3543
Contract Date: Ref. Documents Contract Value : 88.53 Lakh
Government Departments No of Bidders 3
45.
Petroleum and Natural Gas #5628918 AOC
Bids Are Invited For Supply Of Kitchen Equipments Attachment Holding Rack , Dough Kneeding Machine , Marble Top Spreader Table , Chapati Plate With Puffer , Chapati Dumping Table-Mobile , Mobile Glass Rack Trolley 4 Tier , Water Cooler With Ro And Complete Filter Setup , 4Gn Pan Hot With Netural Bain Marie And Sneeze Guard , Work Counter , Multi Juicer , Blender With Sound Enclosure With Accessories , Sandwich Griller , Two Door Refrigerator With Top Freezer , Induction Plate , Conveyor Toast Machine , Soiled Dish Drop Off Table Two Sink And Garbage Chute , Mobile Garbage Can Wheeled , Pre- Rinse Spray Unit With Faucet , Water Geyser Capacity Instant 25L , Hood Type Dish Washing Machine With Accessories , Clean Dish Landing Table With Under Storage , Plate Basket Rack For Dishwasher Machine , Glass Basket Rack For Dishwasher Machine , Cutlary Basket Rack For Dishwasher Machine , Flushing Hose Unit 12M , Mobile Clean Dish Rack , 4Gn Pan Hot With 1 Netural Bain Marie And Sneeze Guard , Blender With Sound Enclosure , Work Counter With 2Under Storage , Double Plate Warmer-100 Plates 800 Watts , Soiled Dish Drop Off Table With Two Sink And Garbage Chute , Water Geyser Insta Heat Of Minimum 25L Capacity , Blower With All Electrical Accessories Including Switch, Starter And Db Box , Gi Ducting For Exhaust Hood With All Accessories For Clamping,Fixing And Supports , Dampers , Canves With Mesh T-304 For Rodent Protection , Ms Stand With Anti Vibration Pad 2 77 Total Quantity : 4207
Contract Date: Ref. Documents Contract Value : 58.58 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 9
46.
Petroleum and Natural Gas #5544323 AOC
Bids Are Invited For Providing Er Vehicle With Driver Mahindra Pick-Uptatapick-Up- Equivalent 24X7 For Routine And .., - All Details As Per Technical Doc. , Running Km Of Erv Km Per Month Rates Shall Be Paid On The Basis Of Actual Running Kms.- All Details As Per Technical Document..., - All Details As Per Technical Doc. , Hiring Of Motor Cycle For Pipe Line Patrolling With Gps Enabled Mobile Devices For Monitoring And Surveillance And Safety Of Hpcls Pipelines- Installations Etc.., - All Details As Per Technical Doc. , Running Km Of Motor Cycle Km Per Month Rates Shall Be Paid On The Basis Of Actual Running Kms.- All Details As Per Technical Document..., - All Details As Per Technical Doc. , Hiring Of Jcb As Per Site Requirement- All Details As Per Technical Document..., - All Details As Per Technical Doc. , Hiring Of Hydra - 5 Mt Capacity- All Details As Per Technical Document..., - All Details As Per Technical Doc. , Hiring Of Hydra - 10 Mt Capacity.- All Details As Per Technical Document..., - All Details As Per Technical Doc. , Hiring Of Crane - 20 Mt Capacity For - All Details As Per Technical Document..., - All Details As Per Technical Doc. , Hiring Of Ladder Up To 25 Feets - All Details As Per Technical Document..., - All Details As Per Technical Doc. , Hiring Of Diesel Generator Set - 15 Kva- All Details As Per Technical Document..., - All Details As Per Technical Doc. , Hiring Of Dewatering Pump - All Details As Per Technical Document..., - All Details As Per Technical Doc. , Hiring Of Concrete - Rock Breaker - All Details As Per Technical Document..., - All Details As Per Technical Doc. , Hiring Of Compressor For Flushing And Testing Up To 100 Cfm- All Details As Per Technical Document..., - All Details As Per Technical Doc. , Hiring Of Tractor And Trolley- All Details As Per Technical Document..., - All Details As Per Technical Doc. , Pe Fittings For Size Above 63 Mm- All Details As Per Technical Document..., - All Details As Per Technical Doc. , Pe Fittings For Size Equal To Or Lower Than 63 Mm- All Details As Per Technical Document..., - All Details As Per Technical Doc. , Pe Valves For Size Higher Than 63 Mm - All Details As Per Technical Document..., - All Details As Per Technical Doc. , Pe Valves For Size 63 Mm Or Lower- All Details As Per Technical Document..., - All Details As Per Technical Doc. , Gi Pipes Of Size 1-2 Inch To 1.5 Inch- All Details As Per Technical Document..., - All Details As Per Technical Doc. , Copper Tube- All Details As Per Technical Document..., - All Details As Per Technical Doc. , Gi Fittings Of Various Sizes From 1-2 Inch To 1.5 Inch- All Details As Per Technical Document..., - All Details As Per Technical Doc. , Ss 316 Anaconda- All Details As Per Technical Document..., - All Details As Per Technical Doc. , Blind Meter Adaptor- Gi Temporary Disconnetion Of Dom. Customers- All Details As Per Technical Document..., - All Details As Per Technical Doc. , Meter Adapter - Brass For G1.6, G-6, G-10, G-16, G-25 Meters- All Details As Per Technical Document..., - All Details As Per Technical Doc. , Isolation Ball Valve Of Size 1.5 Inch- All Details As Per Technical Document..., - All Details As Per Technical Doc. , Isolation Ball Valve Of Size 3-4 Inch To 1 Inch- All Details As Per Technical Document..., - All Details As Per Technical Doc. , Isolation Ball Valve Of Size 1-2 Inch- All Details As Per Technical Document..., - All Details As Per Technical Doc. , Appliance Valve Of Size 1-4 Inch To 1-2 Inch- All Details As Per Technical Document..., - All Details As Per Technical Doc. , Ss 316 Tubes Of Size 3-4 Inch And 1-2 Inch - All Details As Per Technical Document..., - All Details As Per Technical Doc. , Ss Fittings Of Size 3-4 Inch And 1-2 Inch- All Details As Per Technical Document..., - All Details As Per Technical Doc. , 2 Way And 3 Way Ss Ball Valves Of Size 3-4 Inch And 1-2 Inchall Details As Per Technical Document..., - All Details As Per Technical Doc. , 12 Inch Dia. 300 Class- All Details As Per Technical Document..., - All Details As Per Technical Doc. , 10 Inch Dia. 300 Class- All Details As Per Technical Document..., - All Details As Per Technical Doc. , 8 Inch Dia. 300 Class- All Details As Per Technical Document..., - All Details As Per Technical Doc. , 6 Inchdia. 300 Class- All Details As Per Technical Document..., - All Details As Per Technical Doc. , 4 Inch Dia. 300 Class- All Details As Per Technical Document..., - All Details As Per Technical Doc. , 4 Inch Dia. 600 Class- All Details As Per Technical Document..., - All Details As Per Technical Doc. , Supply And Application Of Liquid Epoxy Paint Powercrete R95 Along With Applicator Pad Kit- All Details As Per Technical Document..., - All Details As Per Technical Doc. , 6 Inch Dia. 300 Class- All Details As Per Technical Document..., - All Details As Per Technical Doc. , 4 Inch Dia.300 Class- All Details As Per Technical Document..., - All Details As Per Technical Doc. , 12 Inch Dia.- All Details As Per Technical Document..., - All Details As Per Technical Doc. , 10 Inch Dia.- All Details As Per Technical Document..., - All Details As Per Technical Doc. , 8 Inch Dia.- All Details As Per Technical Document..., - All Details As Per Technical Doc. , 6 Inch Dia.- All Details As Per Technical Document..., - All Details As Per Technical Doc. , 4 Inch Dia.- All Details As Per Technical Document..., - All Details As Per Technical Doc. , Mdpe Pipe Line Repairing Including Excavation, Leakage Arrest, Jointing And Restoration Of Any Dia Up-To 63 Mm And Below Including Supply And Installation Of A.., - All Details As Per Technical Doc. , Mdpe Pipe Line Repairing Including Excavation, Leakage Arrest, Jointing And Restoration Of Any Dia Above 63 Mm Including Supply And Installation Of All Fittings.., - All Details As Per Technical Doc. , Laying Of Pipe Line Upto 63 Mm Dia By Any Method As Per Instruction Of Eic- All Details As Per Technical Document..., - All Details As Eic- All Details As Per Technical Document..., - All Details As Per Technical Doc. , Laying Of Pipe Line Above 63 Mm Dia By Any Method Without Casing As Per Instruction Of Eic- All Details As Per Technical Document..., - All Details As Per Technical Doc. , Laying Of Pipe Line Above 63 Mm Dia By Any Method With Casing As Per Instruction Of Eic- All Details As Per Technical Document..., - All Details As Per Technical Doc. , Laying Of Pipe Line Of Size Upto 63 Mm Dia. By Any Method With Or Without Casing- All Details As Per Technical Document..., - All Details As Per Technical Doc. , Laying Of Pipe Line Of Size 90 And 125 Mm Dia. By Any Method With Or Without Casing- All Details As Per Technical Document..., - All Details As Per Technical Doc. , Replacement Of Old Transition Fittings Wirh New Transition Fitting - All Details As Per Technical Document..., - All Details As Per Technical Doc. , Temporary Disconnection Of Mdpe Service Pipe Line For Existing User- All Details As Per Technical Document..., - All Details As Per Technical Doc. , Construction Of Pedestal - 300Mm X 300 Mm X 300 Mm- All Details As Per Technical Document..., - All Details As Per Technical Doc. , Sand Filling In All Type Of Sleeves - 2.5 Nb X 300 Mm - All Details As Per Technical Document..., - All Details As Per Technical Doc. , Supply Of Reinforced Rubber Hose With Clamps - Upto 1.00 Mtr- All Details As Per Technical Document..., - All Details As Per Technical Doc. , Supply Of Reinforced Rubber Hose With Clamps - More Than 1.00 Mtr And Upto 1.50 Mtr- All Details As Per Technical Document..., - All Details As Per Technical Doc. , Shifting And Installations Of Drs-Dcu Skids For Weight Upto 5 Tonnes- All Details As Per Technical Document..., - All Details As Per Technical Doc. , Supply And Installation Of New Canopy Over Air Compressor- All Details As Per Technical Document..., - All Details As Per Technical Doc. , Cascade Inspection-Maintenance As Per Oem Guidelines- All Details As Per Technical Document..., - All Details As Per Technical Doc. , Painting Of Piping And Structure - Electrical Pole - Crash Barrier- All Details As Per Technical Document..., - All Details As Per Technical Doc. , Painting Of Wire Mesh - Fencing- All Details As Per Technical Document..., - All Details As Per Technical Doc. , Installation Of Ss -304-304L-316-316L Tubing Including Bending, Testing And Commissioning With Consumable Such As Teflon Tap Etc For 1-2 Inch- All Details As P.., - All Details As Per Technical Doc. , Installation Of Ss304-304L-316-316L Tubing Including Bending, Testing And Commissioning With Consumable Such As Teflon Tap Etc For 3-4 Inch.- All Details As P.., - All Details As Per Technical Doc. , Supply And Installation Of Warning Tape - Anti- Rodent Tape As Per Owner Specification- All Details As Per Technical Document..., - All Details As Per Technical Doc. , Rcc Route Marker- All Details As Per Technical Document..., - All Details As Per Technical Doc. , Pole Marker With Foundation- All Details As Per Technical Document..., - All Details As Per Technical Doc. , Plate Marker- All Details As Per Technical Document..., - All Details As Per Technical Doc. , Scrapping Of Moss, Blister Etc.Thoroughly From Surface Of Walls With Scrapper- Wire Brush Complete In All Respects As Per Specifications And Directions Of Engine.., - All Details As Per Technical Doc. , Removing Loose Scales, Blisters Etc From Old Painted Steel Or Wooden Surface By Scrapping With Wire Brush Thoroughly And Smoothening The Surface To Make It Suita.., - All Details As Per Technical Doc. , Two Coats Including Priming Coat- All Details As Per Technical Document..., - All Details As Per Technical Doc. , Surface Dressing And Grading Of The Ground Including Removing Vegetation And Leveling The Undulations Up To The Depth Of 15 Cms Cutting Andfilling Up To 15Cm, R.., - All Details As Per Technical Doc. , Housekeeping Works At Cgs -Ms-Drs-Dcu Technical Doc. , Housekeeping Works At Cgs -Ms-Drs-Dcu Etc. Including Maintenance Of Grass, Cutting, Trimming, Removing Grass, Dusting , Cleaning Area, Vegetation Including Labo.., - All Details As Per Technical Doc. , 1-3-6 1 Cement-3 Sand- 6 Stone Aggregate 20 Mm Nominal Size.- All Details As Per Technical Document..., - All Details As Per Technical Doc. , 1-2-4 1 Cement-2 Sand-4 Stone Aggregate 20 Mm Nominal Size.- All Details As Per Technical Document..., - All Details As Per Technical Doc. , 1-1.5-3 1 Cement- 1.5 Coarse Sand Zone-Iii- 3 Graded Stone Aggregate 20 Mm Nominal Size In Foundation And Plinth Excluding Form Work And The Cost Of Reinforceme.., - All Details As Per Technical Doc. , 1-2-4 1 Cement-2 Sand- 4 Stone Aggregate 20 Mm Nom. In Foundation And Plinth Excluding Form Work And The Cost Of Reinforcement Bars.- All Details As Per Technic.., - All Details As Per Technical Doc. , In 1-4 Cement Sand Mortar 1 Cement - 4 Medium Coarse Sand - All Details As Per Technical Document..., - All Details As Per Technical Doc. , Providing Brick On Edge Flooring With 2Nd Class Brick In Cm 1-4 1 Cement - 4 Sand Including Preparation Of Base Including Filling The Joints With Cement Morta.., - All Details As Per Technical Doc. , C.M. 1-4 1 Cement - 4 Sand- All Details As Per Technical Document..., - All Details As Per Technical Doc. , Providing And Placing In Position 125 Mm Thick Factory Made Machine Batched And Machine Mixed Precast Rcc Rectangular Covers On Trenches Of Various Sizes, Of M-.., - All Details As Per Technical Doc. , Supply, Fabrication And Installation Of Steel Work Welded In Built Up Sections- Framed Work, Including Cutting, Hoisting, Fixing In Position And Applying A Prim.., - All Details As Per Technical Doc. , Surface Preparation, Supply And Painting Steel Work With Deluxe Multi Surface Paint To Give An Even Shade.. - All Details As Per Technical Doc. , Supplying, Fabricating, Erecting, Placing And Fixing In Position Structural Steel Work Riveted .., - All Details As Per Technical Doc. , Providing And Applying 2.5 Mm Thick Road Marking Strips Retro-Reflective Of Specified Shade- Colour Using Hot Thermoplastic Material By Fully- Semi Automatic Th.., - All Details As Per Technical Doc. , Suppy Of Steel Reinforcement For R.C.C. Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Upto Plinth Level.Thermo-Me.., - All Details As Per Technical Doc. , Excavation In All Types Of Rock Hard - Ordinary -Excavation Work In Rock All Types - Hard - Ordinary By Mechanical Means Hydraulic - Pneumatic Excavator And Han.., - All Details As Per Technical Doc. , Backfilling, Compaction, Leveling Of Excavated Pit - Trecnchbackfilling Of The Excavated Pit-Trench By Hydraulic Means Jcb-Manual Means, Soil Excluding Rock Re.., - All Details As Per Technical Doc. , Supply, Installation Of 6A Dp Mcb In Panels For Use With All Material And Labour As Per Specifications, Drawings And Instruction Of Engineer-Incharge. Work T.., - All Details As Per Technical Doc. , Supply, Installation Of 10A Dp Mcb In Panels For Use With All Material And Labour As Per Specifications, Drawings And Instruction Of Engineer-In-Charge. Work .., - All Details As Per Technical Doc. , Supply, Installation Of 16A Tpand N Mcb In Panels For Use With All Material And Labour As Per Specifications, Drawings And Instruction Of Engineer-In-Charge. .., - All Details As Per Technical Doc. , Supply, Installation Of 32A, 4P, Mccb In Panels For Use With All Material And Labour As Per Specifications, Drawings And Instruction Of Engineerin-Charge. Work.., - All Details As Per Technical Doc. , Supply, Laying, Termination, Testing And Commissioning, Restoration Of 1.1Kv, 3Cx 4 Sqmm Al Cable , Xlpe Insulated, Armoured, For Power Cable, Pvc Sheathed, Frl.., - All Details Armoured, For Power Cable, Pvc Sheathed, Frl.., - All Details As Per Technical Doc. , Supply, Installation, Testing And Commissioning Of Wiring For Light Point With 2.5 Sq. Mm Frls Pvc Insulated Copper Conductor Three Core Cable-Wire In Surface-.., - All Details As Per Technical Doc. , Supply, Installation, Testing And Commissioning Of Double Compressed Brass Cable Glands Flp Gland As Per Requirement Of Sizes Upto 1 Inch- All Details As Per .., - All Details As Per Technical Doc. , Supply, Installation, Testing And Commissioning Of Double Compressed Brass Cable Glands Flp Gland As Per Requirement Of Sizes Upto2 Inchall Details As Per T.., - All Details As Per Technical Doc. , Supply, Installation, Testing And Commissioning Of Area Light Fixtures Flp 110 W Led Well Glass Fixtures For Mounted On Light Pole, Street Industrial Ligh.., - All Details As Per Technical Doc. , Measurement, Testing And Maintenance Of Complete Earth Pit And Grid Resistance On Half Yearly Basis With Name Plate Including Supply And Erection For Damaged G.., - All Details As Per Technical Doc. , Measurement, Testing And Maintenance Of Complete Earth Pit And Grid Resistance On Half Yearly Basis With Name Plate Including Supply And Erection For Damaged C.., - All Details As Per Technical Doc. , Supply, Installation And Testing Of Indication Lamp Of Electrical Panels- All Details As Per Technical Document..., - All Details As Per Technical Doc. , Supply, Installation, Testing, Commissioning Of 6-16A, 230 Volt Ac, 5 Pin Switch Socket Assembly For Indoor Use With All Material And Labour As Per Specificati.., - All Details As Per Technical Doc. , Jointing - Splicing Of Optical Fiber Cable 24 Fibers Including Supply Of Optical Splice Closer With Electronic Marker.- All Details As Per Technical Document..., - All Details As Per Technical Doc. , Dry Chemical Powder- All Details As Per Technical Document..., - All Details As Per Technical Doc. , 4.5 Kg Co2 Cylinder- All Details As Per Technical Document..., - All Details As Per Technical Doc. , 6.8 Kg Co2 Cylinder- All Details As Per Technical Document..., - All Details As Per Technical Doc. , 10 Kg Dcp Cylinder- All Details As Per Technical Document..., - All Details As Per Technical Doc. , 75 Kg Dcp Cylinder- All Details As Per Technical Document..., - All Details As Per Technical Doc. , Rubber Washer For Extinguisher- All Details As Per Technical Document..., - All Details As Per Technical Doc. , Co2 Safety Valves 155Kgf-Cm2- All Details As Per Technical Document..., - All Details As Per Technical Doc. , Co2 Safety Pins- All Details As Per Technical Document..., - All Details As Per Technical Doc. , Isi Marked Discharge Pipe With Horn For 6.5 Kg And 6.8Kg Co2exitinguishers.- All Details As Per Technical Document..., - All Details As Per Technical Doc. , Rubber Gasket Of Dcp Main Cap- All Details As Per Technical Document..., - All Details As Per Technical Doc. , Dcp Main Cap Gun Metal Cp- All Details As Per Technical Document..., - All Details As Per Technical Doc. , Dcp Plunger Pin With Spring- All Details As Per Technical Document..., - All Details As Per Technical Doc. , Dcp Plunger Top- All Details As Per Technical Document..., - All Details As Per Technical Doc. , Squeezing Grip Plastic Nozzle- All Details As Per Technical Document..., - All Details As Per Technical Doc. , Dcp Cylinder Discharge Pipe Of Sufficient Length For 10 Kg Capacity Fire Extinguisher- All Details As Per Technical Document..., - All Details As Per Technical Doc. , Dcp Cylinder Discharge Pipe Of Sufficient Length For 75 Kg Capacity Fire Extinguisher- All Details As Per Technical Document..., - All Details As Per Technical Doc. , Spray-Brush Painting Of Fire Bucket Stand With Its Bucket 4-6 Bucketincluding Letternumber Writing.- All Details As Per Technical Document..., - All Details As Per Technical Doc. , Spray Painiting Of Fire Extinguishers Of All Sizes Includingletter-Number Writing.- Extinguishers Of All Sizes Includingletter-Number Writing.- All Details As Per Technical Document..., - All Details As Per Technical Doc. , Air Filling In Cylinders Of Breathing Apparatus With Transportation- All Details As Per Technical Document..., - All Details As Per Technical Doc. , Hydraulic Testing Of Co2 Cylinders 2 To 4.5Kg-Cm2- All Details As Per Technical Document..., - All Details As Per Technical Doc. , Hydraulic Testing Of Co2 Cylinders 6.8Kg-Cm2- All Details As Per Technical Document..., - All Details As Per Technical Doc. , Hydraulic Testing Of Dcp Cylinders Of All Sizes- All Details As Per Technical Document..., - All Details As Per Technical Doc. , Supply, Installation, Testing And Commissioning Of Hand Operated Siren Of Range 500M- All Details As Per Technical Document..., - All Details As Per Technical Doc. , Temperature Gauge With Thermowell Of Range 0 To 60 Deg.C As Per The Technical Data Sheet Attached In Technical Tender. - All Details As Per Technical Document..., - All Details As Per Technical Doc. , Mechanical - Electrical Technician - Skilledall Details As Per Technical Document..., - All Details As Per Technical Doc. , Pe Technician - Skilled- All Details As Per Technical Document..., - All Details As Per Technical Doc. , Plumber - Skilled- All Details As Per Technical Document..., - All Details As Per Technical Doc. , Helpers Un-Skilled- All Details As Per Technical Document..., - All Details As Per Technical Doc. , Hse Officer - Highly Skilled- All Details As Per Technical Document..., - All Details As Per Technical Doc. , Patrolling Man - Skilled- All Details As Per Technical Document..., - All Details As Per Technical Doc. , Front Desk Executive - Skilled- All Details As Per Technical Document..., - All Details As Per Technical Doc. , Semi Skilled - Cost Includes Uniform - Ppes- Welfare Charges And Other Expenses- All Details As Per Technical Document..., - All Details As Per Technical Doc. , Un Skilled Labour - Cost Includes Uniform - Ppe S- Welfare Charges And Other Expenses- All Details As Per Technical Document..., - All Details As Per Technical Doc. , Skilled Labour- All Details As Per Technical Document..., - All Details As Per Technical Doc. , Providing Additional Manpower On Hourly Rates And When Required And Instructed By Eic On Need Basis. - All Details As Per Technical Document..., - All Details As Per Technical Doc. Total Quantity : 261956
Contract Date: Ref. Documents Contract Value : 3.00 Crore
Statutory Bodies & Commissions/Committees No of Bidders 8
Uttar Pradesh View Result →
47.
Housing Urban and Rular Development #5085969 AOC
Setting Up Of Real Time Data Acquisition System, Hydro Modelling Flood Control Room At Ezhilagam And Flood Monitoring Centres For Water Resources Department Headquarters At Chepauk And Four Collectorates Setting Up Of Real Time Data Acquisition System, Hydro Modelling Flood Control Room At Ezhilagam And Flood Monitoring Centres For Water Resources Department Headquarters At Chepauk And Four Collectorates , I Field Equipment Arg Locations With Gprs / Gsm- 63 Locations , Arg Sensor With Required Accessories And Mounting Setup As Per Technical Specification No: 8.1, 8.6.1, 8.8.1 , Soil Moisture Probe With Required Accessories And Mounting Setup As Per Technical Specification No: 8.2, 8.6.1, 8.8.1 , Civil Works As Per The Drawing No: Cfm-Arg , Installation, Testing And Commissioning , Arg Locations With Gprs / Gsm And Vsat- 23 Locations , Arg Sensor With Required Accessories And Mounting Setup As Per Technical Specification No: 8.1, 8.6.1 8.6.2, 8.8.1 , Soil Moisture Probe With Required Accessories And Mounting Setup As Per Technical Specification No: 8.2, 8.6.1 8.6.2, 8.8.1 , Civil Works As Per The Drawing No: Cfm-Arg , Installation, Testing And Commissioning , Aws Locations With Gprs / Gsm- 2 Locations , Aws With Gsm / Gprs Mode Of Transmission As Per Technical Specification No: 8.4, 8.6.2, 8.8.2 , Civil Works As Per The Drawing No: Cfm-Aws , Installation, Testing And Commissioning , Aws Locations With Gprs / Gsm And Vsat- 6 Locations , Aws With Gsm / Gprs And Vsat Mode Of Transmission As Per Technical Specification No: 8.4 &8.6.1, 8.6.2, 8.8.2 , Civil Works As Per The Drawing No: Cfm-Aws , Installation, Testing And Commissioning , Awlr ( Se ) Locations With Gprs / Gsm In Existing Gauge Well- In 76 Waterbody Locations , Awlr With Shaft Encoder Based Sensor With Required Accessories And Mounting Setup - Data Logger With Min. 2 Sensor Connectivity As Per Technical Specification No: 8.3.1, 8.6.1, 8.8.1 , Civil Works As Per The Drawing Nos In Annexure – Drawings And Technical Specification No:7 , Installation, Testing And Commissioning , Awlr ( Se ) Locations With Gprs / Gsm, Vsat In Existing Gauge Well- In 2 Waterbody Location , Awlr With Shaft Encoder Based Sensor With Required Accessories And Mounting Setup - Data Logger With Min. 2 Sensor Connectivity, As Per Technical Specification No: 8.3.1, 8.6.2, 8.8.1 , Civil Works As Per The Drawing Numbers In Annexure- Drawings And Technical Specification No:7 , Installation, Testing And Commissioning , Awlr ( Se ) Locations With Gprs / Gsm In New Gauge Well- In11 Waterbody Locations , Awlr With Shaft Encoder Based Sensor With Required Accessories And Mounting Setup - Data Logger With Min. 2 Sensor Connectivity As Per Technical Specification No: 8.3.1, 8.6.1, 8.8.1 , Civil Works For New Gauge Well As Per The Drawing Nos In Annexure – Drawings And Technical Specification No:7 , Installation, Testing And Commissioning , Awlr ( R ) Locations With Gprs / Gsm, New Frame And Radar Based System- In 7 Waterbody Locations , Awlr With Radar Based Sensor With Required Accessories And Mounting Setup - Data Logger With Min. 2 Sensor Connectivity, As Per Technical Specification No: 8.3.2, 8.6.1, 8.8.1 , Required Civil Works For New Frame Structure, As Per The Drawing Nos In Annexure – Drawings And Technical Specification No:7 , Installation, Testing And Commissioning , Awlr ( R ) Locations With Gprs / Gsm, In New Frame And Radar Based System- In 16 Waterway Locations , Awlr With Radar Based Sensor With Required Accessories And Mounting Setup - Data Logger With Min. 2 Sensor Connectivity, As Per Technical Specification No: 8.3.2, 8.6.1, 8.8.1 , Civil Works For New Frame Structure As Per The Drawing Nos In Annexure – Drawings And Technical Specification No:7 , Installation, Testing And Commissioning , Awlr ( R ) Locations With Gprs / Gsm, Vsat, New Frame And Radar Based System- In 12 Waterway Locations , Awlr With Radar Based Sensor With Required Accessories And Mounting Setup - Data Logger With Min. 2 Sensor Connectivity, As Per Technical Specification No: 8.3.2, 8.6.2, 8.8.1 , Civil Works For New Frame / Box Structure As Per The Drawing Nos In Annexure – Drawings And Technical Specification No:7 , Installation, Testing And Commissioning , Awlr ( Se ) Locations With Gprs / Gsm Innew Gauge Well- In 4 Waterway Locations , Awlr With Shaft Encoder Based Sensor With Required Accessories And Mounting Setup - Data Logger With Min. 2 Sensor Connectivity As Per Technical Specification No: 8.3.1, 8.6.1, 8.8.1 , Civil Works ( New Gauge Well ) As Per The Drawing Nos In Annexure – Drawings And Technical Specification No:7 , Installation, Testing And Commissioning , Awlr ( Se ) Locations With Gprs / Gsm, Vsat In New Gauge Well- In 1 Waterway Locations , Awlr With Shaft Encoder Based Sensor With Required Accessories And Mounting Setup - Data Logger With Min. 2 Sensor Connectivity, As Per Technical Specification No: 8.3.1, 8.6.2, 8.8.1 , Civil Works For New Gauge Well, As Per The Drawing Nos In Annexure – Drawings And Technical Specification No:7 , Installation, Testing And Commissioning , Awlr ( R ) , Aws, Gate Sensor Locations With Gprs / Gsm, Vsat ( 1 No. ) - Chembarambakkam Lake , Awlr With Radar Based Sensor With Required Accessories And Mounting Setup - Data Logger With Min. 2 Sensor Connectivity, As Per Technical Specification No: 8.3.2, 8.6.2 & 8.8.2 , Aws With Sensors As Per Technical Specification - Data Logger With Min. 8 Sensor Connectivity As Per Technical Specification No: 8.4, 8.6.2 & 8.8.2 , Gate Sensors ( 24Nos ) With Required Accessories And Mounting Setup - Data Logger With Min. 24 Sensor Connectivity 8.5, 8.6.2 & 8.8.2 , Cctv Camera With Inbuilt Ir Illuminator With Required Accessories And Mounting Setup , Civil Works For Aws , Awlr And Gate Sensors Including Mounting Frame As Per The Drawing Nos In Annexure – Drawings And Technical Specification No:7 , Installation, Testing And Commissioning , Awlr ( R ) , Aws, Gate Sensor Locations With Gprs / Gsm, Vsat ( 1 No. ) - Poondi Lake , Awlr With Radar Based Sensor With Required Accessories And Mounting Setup - Data Logger Included With Gate Sensory As Per Technical Specification No: 8.3.2, 8.6.2 & 8.8.2 , Aws With Sensors As Per Technical Specification - Data Logger With Min. 8 Sensor Connectivity As Per Technical Specification No: 8.4, 8.6.2 & 8.8.2 , Gate Sensors ( 16Nos ) With Required Accessories And Mounting Setup - Data Logger With Min. 18 ( Iincl 2 For Awlr ) Sensor Connectivity As Per Technical Specification No: 8.5, 8.6.2 & 8.8.2 , Cctv Camera With Inbuilt Ir Illuminator With Required Accessories And Mounting Setup , Civil Works For Aws , Awlr And Gate Sensors Including Mounting Frame As Per The Drawing Nos In Annexure – Drawings And Technical Specification No:7 , Installation, Testing And Commissioning , Awlr ( R ) , Aws, Gate Sensor Locations With Gprs / Gsm, Vsat ( 1 No. ) - Redhills Lake , Awlr With Radar Based Sensor With Required Accessories And Mounting Setup - Data Logger With Gate Sensor Connectivity As Per Technical Specification No: 8.3.2, 8.6.1& 8.8.2 , Aws With Sensors As Per Technical Specification - Data Logger With Min. 8 Sensor Connectivity As Per Technical Specification No: 8.4, 8.6.2 & 8.8.2 , Gate Sensors ( 2Nos ) With Required Accessories And Mounting Setup - Data Logger With Min.4 Sensor Connectivity As Per Technical Specification No: 8.5, 8.6.2 & 8.8.2 , Cctv Camera With Inbuilt Ir Illuminator With Required Accessories And Mounting Setup , Civil Works For Aws , Awlr And Gate Sensors Including Mounting Frame As Per The Drawing Nos In Annexure – Drawings And Technical Specification No:7 , Installation, Testing And Commissioning , Awlr ( R ) , Aws, Gate Sensor Locations With Gprs / Gsm, Vsat ( 1 No. ) - Thervoy Lake , Awlr With Radar Based Sensor With Required Accessories And Mounting Setup - Data Logger With Min. 2 Sensor Connectivity As Per Technical Specification No: 8.3.2, 8.6.1& 8.8.2 , Aws With Sensors As Per Technical Specification - Data Logger With Min. 8 Sensor Connectivity As Per Technical Specification No: 8.4, 8.6.2 & 8.8.2 , Cctv Camera With Inbuilt Ir Illuminator With Required Accessories And Mounting Setup , Civil Works For Aws And Awlr Including Mounting Frames As Per The Drawing Nos In Annexure – Drawings And Technical Specification No:7 , Installation, Testing And Commissioning , Awlr ( R ) , Aws Location With Gprs / Gsm, Vsat ( 1 No. ) - Cholavaram Lake , Awlr With Radar Based Sensor With Required Accessories And Mounting Setup - Data Logger With Min. 2 Sensor Connectivity As Per Technical Specification No: 8.3.2, 8.6.2, 8.8.2 , Aws With Sensors As Per Technical Specification - Data Logger With Min. 8 Sensor Connectivity As Per Technical Specification No: 8.4, 8.6.2 & 8.8.2 , Cctv Camera With Inbuilt Ir Illuminator With Required Accessories And Mounting Setup , Civil Works For Aws And Awlr Including Mounting Frames As Per The Drawing Nos In Annexure – Drawings And Technical Specification No:7 , Installation, Testing And Commissioning , Awlr ( R ) , Gs Location With Gprs / Gsm - Nandhambakkam Check Dam , Awlr With Radar Based Sensor With Required Accessories And Mounting Setup - Data Logger With Min. 2 Sensor Connectivity As Per Technical Specification No: 8.3.2, 8.6.1 & 8.8.1 , Gate Sensors ( 14Nos ) With Required Accessories And Mounting Setup - Data Logger With Min. 16 Sensor Connectivity As Per Technical Specification No: 8.5, 8.6.1, 8.8.2 , Cctv Camera With Inbuilt Ir Illuminator With Required Accessories And Mounting Setup , Civil Works For Awlr And Gate Sensors Including Mounting Frames As Per The Drawing Nos In Annexure – Drawings And Technical Specification No:7 , Installation, Testing And Commissioning , Awlr ( R ) Location With Gprs / Gsm -Feeder Canal Regulator And Kp-Tk Canal Regulator ( 2 Sites ) , Awlr Withradar Based Sensors ( 2 Nos ) With Required Accessories And Mounting Setup - Data Logger With Min. 2 Sensor Connectivity ( 1 No ) As Per Technical Specification No: 8.3.2, 8.6.1& 8.8.1 , Awlr With Radar Based Sensor ( 1 No ) With Required Accessories And Mounting Setup - Data Logger With Min. 2 Sensor Connectivity ( 1 No ) As Per Technical Specification No: 8.3.2, 8.6.1, 8.8.1 , Civil Works For Awlr Including Mounting Frames As Per The Drawing Nos In Annexure – Drawings And Technical Specification No:7 , Installation, Testing And Commissioning , Awlr ( R ) , Gs Location With Gprs / Gsm, Vsat ( 3 Nos. ) - Kesavaram Anicut And Two Downstream Bridges ( Three Sites ) , Awlr With Radar Based Sensor With Required Accessories And Mounting Setup - Data Logger With Min. 2 Sensor Connectivity As Per Technical Specification No: 8.3.2, 8.6.2 & 8.8.1 , Gate Sensors ( 16Nos ) With Required Accessories And Mounting Setup – One Data Logger With Min. 18 Sensor Connectivity As Per Technical Specification No: 8.5, 8.6.2 & 8.8.2 , Civil Works For Awlr Including Mounting Frames As Per The Drawing Nos In Annexure – Drawings And Technical Specification No:7 , Installation, Testing And Commissioning , Awlr Location With Gprs / Gsm - Araniar Anicut , Awlr Withradar Based Sensors ( 2 Nos ) With Required Accessories And Mounting Setup - Data Logger With Min. 2 Sensor Connectivity ( 1 No ) As Per Technical Specification No: 8.3.2, 8.6.1, 8.8.1 , Awlr With Radar Based Sensor ( 1 No ) With Required Accessories And Mounting Setup - Data Logger With Min. 2 Sensor Connectivity ( 1 No ) As Per Technical Specification No: 8.3.2, 8.6.1, 8.8.1 , Civil Works For Awlr Including Mounting Frames As Per The Drawing Nos In Annexure – Drawings And Technical Specification No:7 , Installation, Testing And Commissioning , Awlr ( Se ) Aws, Gs Location With Gprs / Gsm, Vsat In New Gauge Well ( 1 No. ) - Korattur Anicut , Awlr With Shaft Encoder Based Sensor With Required Accessories And Mounting Setup - Data Logger With Min. 2 Sensor Connectivity – Right Bank As Per Technical Specification No: 8.3.1, 8.6.2 & 8.8.1 , Aws With Sensors As Per Technical Specification - Data Logger With Min. 8 Sensor Connectivity – Right Bank As Per Technical Specification No: 8.4, 8.6.2 & 8.8.2 , Gate Sensors ( 4 Nos ) With Required Accessories And Mounting Setup – One Data Logger With Min. 4 Sensor Connectivity – Right Bank As Per Technical Specification No: 8.5, 8.6.2 & 8.8.2 , Gate Sensors ( 4 Nos ) With Required Accessories And Mounting Setup – One Data Logger With Min. 4 Sensor Connectivity - Left Bank As Per Technical Specification No: 8.5, 8.6.2 & 8.8.2 , Civil Works For New Full Gauge Well And Frame Structures For Awlr As Per The Drawing Nos In Annexure – Drawings And Technical Specification No:7 , Installation, Testing And Commissioning , Awlr ( R ) Location With Gprs / Gsm , Vsat ( 1 No. ) - Vallur Anicut , Awlr With Radar Based Sensor With Required Accessories And Mounting Setup - Data Logger With Min. 2 Sensor Connectivity As Per Technical Specification No: 8.3.2, 8.6.2 & 8.8.1 , Civil Works For New Full Gauge Well And Frame Structures For Awlr As Per The Drawing Nos In Annexure – Drawings And Technical Specification No:7 , Installation, Testing And Commissioning , Plank Type ( Gauge Plate ) Water Level Recorders Including Levelling And Fixing On Existing Permanent Structures , Adcp, Float, Gps, Laptop Inclusive Of All Accessories As Per Thetechncial Specification No: 10.1 , Electromagnetic Current Meters Inclusive Of All Accessories As Per Thetechncial Specification No: 10.2 , Ii Control Room ( Hmcr, Ndrc, Fmc ) Equipment A Hydro Modelling Control Room ( Hmcr ) 1 Location -It Components Servers , 4 Cpu Blade Server ( For Hydro Modelling ) With Required License Operating On Microsoft Windows Including Os And Virtualization Software Cost As Per The Technical Specification No:9.5.1 , 2 Processor Blade Server ( For Database ) Operating On Redhat Linuxincluding Os Cost As Per The Technical Specification No:9.5.2 , 2 Processor Blade Server ( For Hosting Web Dss Application, Gis Server, Email Server And Sms Server ) With Required License Operating On Microsoft Windows Including Os And Virtualization Software Cost As Per The Technical Specification No:9.5.2 , Integratedblade Chassis To House All The Blade Servers , Storage And Network As Per The Technical Specification No:9.5.3 , Software , Backup Software- Should Support Full Vm Back And Granular Restore As Per The Technical Specification No:9.13 , Enterprise Management System With License As Per The Technical Specification No:9.8 , Postgresql On Redhat Linux As Per The Technical Specification No:9.15 ( Notional ) , Rtdas Field Equipment System Software At Data Centre As Per Oem Supplier’S Standards , Mike Suite Of Software For Hydro Modelling. Perpetual And Network License With Dongle. ( All Inclusive For 5 Years ) For Mike Hydro Rainfall Runoff, Mike Flood, Mike Hydro River ( Da ) , Mike 21, Mike +, Mike Operation ( All In Latest Version ) , Customization And Integration With 3Rd Party Systems And The Existing System , Gateways , Sms Package For The Department Users For The Entire Project Duration , Sms Package For The Public ( Required During Oct - Dec Every Year ) , E-Mail Gateway , Gis System [ Geoserve For Web Dss And 3 Q-Gis Desktop And 2 Arcgis Pro ( Latest Version ) With Spatial Analyst ] License , Routers , Datacentre Core Router Networked To All Equipment Using Gpon As Per Technical Specification No:9.1 , Firewalls , Internet And Dc Firewall ( Ngfw ) As Per The Technical Specification No:9.4 , Web Application Firewall As Per The Technical Specification No:9.3 , Anti-Advance Persistent Threat As Per The Technical Specification No:9.2 , Epabx + 20 Digital Phones As Per The Technical Specification No: Section – 9.11 , Vsat Components ( Antenna, Support Structure, Vsat Modem / Router ) As Per The Technical Specification No: Section – 9.19 , Ssl Certificates - Wildcard License With Unlimited Sub Domain Support , Installation, Testing & Commissioning Of Hydro Modelling Control Room ( Hmcr ) – It Components , Connectivity , Internet Leased Line Connectivity For Hydro Modelling Control Room With 100 Mbps 1:1 Bandwidth ( 1+1 ) – Installation , Internet Leased Line Connectivity For Hydro Modelling Control Room To Disaster Recovery On Cloud And Hydro Modelling Control Room To Nearline Dr & Fmc With 100Mbps 1:1 Bandwidth ( 1+1 ) - Installation , Satellite Poolbandwidthcharges Annual Recurring Forback Haulcommunication Between Service Provider Hub And Hydro Modelling Control Room @128 Kbps – Installation , Any Other Items Not Specified Above, But Required For The Completeness Of The Objective Of The Hmcr. ( Specify ) , Hydro Modelling Control Room – 1 Location-Non- It Components , Video Wall Solution - 70 In A 3X2arrangementwith Videowall Management Solution As Per The Technical Specification No:9.17 , 70 Led Display Panels As Per The Technical Specification No:9.18 , Computers , Workstations For Hydro Modelling As Per The Technical Specification No:9.9.1 , Desktops – Control Room As Per The Technical Specification No:9.9.2 , Desktops – Adminas Per The Technical Specification No:9.9.3 , Printers , Network Colour Laser Printers ( A3 Size ) As Per The Technical Specification No:9.10.1 , Network Multifunction Printer ( A4 ) As Per The Technical Specification No:9.10.2 , Sat Phone As Per The Technical Specification No:9.12 , Civil Works Including Site Preparation, Fire Rated False Partition, Civil Partition, Floor Tile, False Ceiling, False Flooring, Floor Strengthening, Doors And Painting Works, Plumbing, Etc Complete As Per The Drawing Nos In Annexure – Drawings And Technical Specification No:- 6, 9, 11 , Electrical Cabling, Panels, Db, Earthing, & Necessary Illumination Devices And Fixtures As Per Technical Specification No: 11 , Ip Based Cctv Surveillance System As Per Technical Specification No:11.16 , Fire Alarm System As Per Technical Specification No:11.12 , Fire Suppression System - Gas Based For Sever, Electrical, Ups & Battery Room As Per Technical Specification No:11.10 , Fire Suppression System- Sprinkler Based For All The Other Area As Per Technical Specification No:11.10 , Aspirating Smoke Detection System As Per Technical Specification No:11.13 , Public Address System As Per Technical Specification No:11.17 , Water Leak Detection System As Per Technical Specification No:11.9 , Rodent Repellent System As Per Technical Specification No:11.15 , Access Control System - Biometric And Card Reader With Required Number Of Access Cards As Per Technical Specification No:11.14 , Comfort Ac For All The Other Rooms As Per Technical Specification No:11.11 , Precision Ac For Server Room As Per Technical Specification No:11.11 , Integrated Building Management System Software , Ups Of Adequate Capacity, 80 Kva Minimum, With 30 Min Power Backup For It Components As Per Technical Specification No:9.16 , Ups Of Adequate Capacity, 30 Kva Minimum, With 30 Min Power Backup For Non-It Components As Per Technical Specification No:9.16 , Diesel Genset Of Adequate Capacity. Minimum 250 Kva, With Automatic Transfer, Shelter And Exhaust Setup As Per Technical Specifications No. 11.18 , Networking Cost ( Passive Components Including Cat6 Cables, Ofc, Cat6 & Fiber Patch Cords, Liu, Rj45 Jack Panels Etc. ) , Furniture , Command Centre Desks ( 4 Seater ) As Per Technical Specification No:11.2 , Sys Admin Desks ( 4 Seater ) As Per Technical Specification No:11.2 , Server Storage Desk As Per Technical Specification No:11.2 , Modelling Workstation Desks As Per Technical Specification No:11.2 , Office Desks, Storage Units As Per Technical Specification No:11.2 , Conference Table ( 16 -Seater Arrangement ) As Per Technical Specification No:11.2 , Ergonomic Chairs – Work As Per Technical Specification No:11.2 , Ergonomic Chairs – Waiting As Per Technical Specification No:11.2 , Installation, Testing & Commissioning Of Hydro Modelling Control Room – Non It Components , Any Other Items Not Specified Above, But Required For The Completeness Of The Objective Of The Hmcr. ( Specify ) , Disaster Recovery ( Dr ) On Cloud , Infrastructure As A Service ( Virtual Machines ) Cost For All The Applications And Database ( Hydro Modelling, Web Dss, Mobile App Sever , Gis Server , Postgresql ) For Five Years , Cloud Storage Primary Storage ( Unified ) With Usable Space 50 Tb For All The Applications And Sensor Data Extendable To 200 Tb. 2 Tb Of Standard Storage + Rest Archive Storagefor Five Years As Per The Technical Specifications – Section 9C , Postgresql On Redhat Linux , Rtdas Field Equipment System Software , Customization And Integration With 3Rd Party Systems And The Existing System , Mobile App ( Crowd Sourcing ) Server , Gis System [ Geoserve For Web Dss And 3 Q-Gis Desktop ] License , Ssl Certificates- Wildcard License With Unlimited Sub Domain Support , Installation, Testing & Commissioning Disaster Recovery ( Dr ) On Cloud , Internet Leased Line Connectivity For Disaster Recovery On Cloud To Hydro Modelling Control Room And Disaster Recovery On Cloudto Nearline Disaster Recovery & Fmc With 100 Mbps 1:1 Bandwidth – Installation , Any Other Items Not Specified Above, But Required For The Completeness Of The Objective Of The Dr On Cloud. ( Specify ) , D. Nearline Dr Centre & Fmc At Wrd Hq -1 No ( It - Component ) Servers , 2 Processor Blade Server ( For Database ) Operating On Redhat Linux Including Os And Virtualization Software Cost As Per The Technical Specification No:9.5.2 , 2 Processor Blade Server ( For Hosting Web Dss Application, Gis Server, Email Serverand Sms Server ) With Required Licenseoperating On Microsoft Windowsincluding Os Costas Per The Technical Specification No:9.5.2 , Integratedblade Chassis To House All The Blade Servers , Storage And Network As Per The Technical Specification No:9.5.3 , Software , Backup Software- Should Support Full Vm Back And Granular Restore As Per The Technical Specification No:9.13 , Enterprise Management System With License As Per The Technical Specification No:9.8 , Postgresql On Redhat Linux As Per The Technical Specification No:9.15 , Rtdas Field Equipment System Software , Mike Suite Of Software For Hydro Modelling. Network License With Dongle. ( All-Inclusive For 5 Years At 3 Months Per Year ) For Mike Hydro Rainfall Runoff, Mike Flood, Mike Hydro River ( Da ) , Mike 21, Mike +, Mike Operation. ( All In Latest Version ) . , Customization And Integration With 3Rd Party Systems And The Existing System , Gis System [ Geoserve For Web Dss And 3 Q-Gis Desktop And 2 Arc Gis Pro With Spatial Analyst ] License , Routers , Datacentre Internet Router As Per The Technical Specification No: 9.1 , Firewalls , Internet And Dc Firewall ( Ngfw ) As Per The Technical Specification No:9.4 , Web Application Firewall As Per The Technical Specification No:9.3 , Anti-Advance Persistent Threat As Per The Technical Specification No:9.2 , Epabx + 20 Digital Phones As Per The Technical Specification No:9.11 , Vsat Components ( Antenna, Support Structure, Vsat Modem / Router ) As Per The Technical Specification No: 9.19 , Ssl Certificates- Wildcard License With Unlimited Sub Domain Support , Installation, Testing & Commissioning , Connectivity , Internet Leased Line Connectivity For Ndrc With 100 Mbps 1:1 Bandwidth ( 1+1 ) – Installation , Internet Leased Line Connectivity For Ndrc To Disaster Recovery On Cloud And Ndrc To Hmcr With 100 Mbps 1:1 Bandwidth ( 1+1 ) – Installation , Satellite Poolbandwidthcharges Annual Recurring Forbackhaulcommunication Between Service Provider Hub And Ndrc @ 128 Kbps – Installation , Any Other Items Not Specified Above, But Required For The Completeness Of The Objective Of The Ndrc. ( Specify ) , Nearline Dr Centre & Fmc At Wrd Hq -1 No ( Non-It ) , Video Wall Solution - 70In A 3 X 2Arrangementwith Videowall Management Solution As Per Technical Specification No:9.17 , 70 Led Displays As Per The Technical Specification No:9.18 , Computers , Workstations For Hydro Modelling As Per Technical Specification No:9.9.1 , Desktops – Control Room As Per Technical Specification No:9.9.2 , Desktops – Adminas Per Technical Specification No:9.9.3 , Printers , Network Colour Laser Printers ( A3 Size ) As Per Technical Specification No:9.10.1 , Network Multifunction Printer ( A4 ) As Per Technical Specification No:9.10.2 , Sat Phone As Per Technical Specification No:9.12 , Civil Works Including Site Preparation, Fire Rated False Partition, Civil Partition, Floor Tile, False Ceiling, False Flooring, Floor Strengthening, Doors And Painting Works, Plumbing, Etc Complete As Per The Drawing Nos In Annexure – Drawings And Technical Specification No:6, 9, 11 , Electrical Cabling, Panels, Db, Earthing, & Necessary Illumination Devices And Fixtures As Per Technical Specification No:11 , Ip Based Cctv Surveillance System As Per Technical Specification No:11.16 , Fire Alarm System As Per Technical Specification No:11.12 , Fire Suppression System - Gas Based For Sever, Electrical, Ups & Battery Room As Per Technical Specification No:11.10 , Fire Suppression System- Sprinkler Based For All The Other Area As Per Technical Specification No:11.10 , Aspirating Smoke Detection System As Per Technical Specification No:11.13 , Public Address System As Per The Technical Specification No: 11.17 , Water Leak Detection System As Per Technical Specification No:11.9 , Rodent Repellent System As Per Technical Specification No:11.15 , Access Control System - Biometric And Card Reader With Required Number Of Access Cards As Per Technical Specification No:11.14 , Comfort Ac For All The Other Rooms As Per Technical Specification No:11.11 , Precision Ac For Server Roomas Per Technical Specification No:11.11 , Integrated Building Management System Software , Ups Of Adequate Capacity, Minimum 80Kva With 30 Min Power Backup For It Componentsas Per Technical Specification No:9.16 , Ups Of Adequate Capacity, Minimum 30Kva With 30 Min Power Backup For Non-It Components As Per Technical Specification No:9.16 , Diesel Genset Of Adequate Capacity, Minimum 125 Kva, With Amf Panels, Shelter And Exhaust Setup As Per Technical Specifications No. 11.18 , Networking Cost ( Passive Components Including Cat6 Cables, Ofc, Cat6 & Fiber Patch Cords, Liu, Rj45 Jack Panels Etc. ) , Furniture , Command Centre Workstation Desks As Per Technical Specification No:11.2 , Office / Modelling Desks As Per Technical Specification No:11.2 , Conference Table ( 10 -Seater Arrangement ) As Per Technical Specification No:11.2 , Ergonomic Chairs As Per Technical Specification No:11.2 , Installation, Testing & Commissioning , Any Other Items Not Specified Above, But Required For The Completeness Of The Objective Of The Ndrc. ( Specify ) , Flood Monitoring Centres ( Fmc ) ( 4 Nos ) In Tiruvallur, Kancheepuram, Chengalpattu, Ranipet ( It & Non It ) , Router As Per Technical Specification No:9.1 , Video Wall Solution - 70 In A 2 X 2 Arrangement With Videowall Management Solution As Per Technical Specification No:9.17 , Computers , Desktop- Control Roomas Per Technical Specification No:9.9.2 , Desktop- Admin Computers As Per Technical Specification No:9.9.3 , Phones , Ip Phone As Per Technical Specification No: 9.11 , Sat Phone As Per Technical Specification No:9.12 , Printers , Network Colour Laser Printers ( A3 Size ) As Per Technical Specification No:9.10.1 , Network Multifunction Printer ( A4 Size ) As Per Technical Specification No:9.10.2 , Passive Cabling Including Cat6 Cables, Patch Panels, Patch Cords Etc. As Per Technical Specification No:11.8 , Ups With Adequate Capacity, Minimum 15 Kva With 30 Minutes Battery Backup And Isolation Transformer As Per Technical Specification No:9.16 , Civil Works Including Site Preparation, Fire Rated False Partition, Civil Partition, Floor Tile, False Ceiling, False Flooring, Floor Strengthening, Doors And Painting Works, Plumbing, Etc Complete As Per The Drawing Nos In Annexure – Drawings And Technical Specification No:6, 9, 11 , Electrical Panel, Db, Cable Trays, Earthing, Light Fixtures, Cabling Including Industrial Sockets And Related Accessories For Racks And Workstation As Per Technical Specification No:11 , Comfort Ac For Control Room As Per Technical Specification No:11.11 , Diesel Genset Of Adequate Capacity, Minimum 50 Kva, Including Required Foundation And Exhaust System , Ip Based Cctv Surveillance System As Per Technical Specification No:11.16 , Fire Alarm System As Per Technical Specification No:11.12 , Portable Fire Suppression System As Per Technical Specification No:11.10 , Access Control System – Card Based As Per Technical Specification No:11.14 , Furniture , Command Centre Workstation Desks ( 3 Seater ) As Per Technical Specification No:11.2 , Office Desks As Per Technical Specification No:11.2 , Conference Table ( 10 -Seater Arrangement ) As Per Technical Specification No:11.2 , Ergonomic Chairs – Work As Per Technical Specification No:11.2 , Ergonomic Chairs – Waiting As Per Technical Specification No:11.2 , Installation, Testing & Commissioning , Internet Leased Line Connectivity For Flood Monitoring Centres ( Fmc ) With 100 Mbps 1:1 Bandwidth ( 1+1 ) – Installation , Any Other Items Not Specified Above, But Required For The Completeness Of The Objective Of The Fmc. ( Specify ) , Other Cost , Training / Capacity Building To Nodal Department’S Officers In Day To Day Operation Of The Hydro Modelling Control Room, Nearline Disaster Recovery Centre And Flood Monitoring Centres For Flood Forecasting And Disaster Management Tasks. , Environmental Management Measures As Required
Contract Date: Jan 30, 2024 Contract Value : 76.38 Crore
Government Departments No of Bidders 4
48.
Educational and Research Institute #4633762 AOC
Bids Are Invited For Custom Bid For Services - Manpower House Keeping, Female Matron, Mess Helper, Jsa, Security Personals Through Outsourcing - Scope Of Work For Cook 1. Menu Planning: Collaborating With The Head Chef Or Kitchen Manager To Plan Menus According To Budget, Dietary Restrictions, And Seasonal Availability Of Ingredients. 2. Food Preparation: Preparing Ingredients For Cooking, Including Washing, Peeling, Chopping, And Marinating. Following Recipes Accurately To Ensure Consistency In Flavor And Presentation. 3. Cooking: Cooking And Baking A Variety Of Dishes, Including Appetizers, Main Courses, Desserts, And Snacks, Using Various Cooking Methods Such As Grilling, Frying, Roasting, And Baking. 4. Quality Control: Monitoring Food Quality During All Stages Of Preparation, Ensuring That Food Safety Standards Are Met, And Maintaining Cleanliness And Hygiene In The Kitchen. 5. Portion Control: Ensuring Portion Sizes Are Consistent And Adhering To Portion Control Guidelines To Minimize Waste And Maximize Profitability. 6. Team Collaboration: Working Collaboratively With Other Kitchen Staff Members To Ensure Smooth Operation Of The Kitchen And Timely Service Of Meals. 7. Adaptability: Being Able To Adapt To Changes In The Menu, Kitchen Procedures, Or Special Dietary Requirements. 8. Cleaning And Maintenance: Cleaning And Sanitizing Kitchen Equipment, Utensils, And Work Areas According To Established Protocols. Assisting With General Kitchen Maintenance Tasks As Needed. 9. Training And Development: Participating In Training Sessions To Enhance Culinary Skills And Staying Updated On Food Safety Regulations And Industry Trends. 10.Shift Management: Adhering To Assigned Work Schedules, Arriving Punctually For Shifts, And Completing Assigned Tasks Within The Specified Time Frame, Scope Of Work Of Clerical Work 1. Daily Office Work And Day To Day Operation In The Office Under The Supervision Of Higher Authority. 2. Maintain The Data, Files And Documents Of The Office In The Prescribed System And Accurate Place. 3. Maintain An Attendance Register Of All Officials As Directed By The Competent Authority And Their Leaves Records. 4. Diarising The Letters / Communications / E-Mail And Files Received. 5. Distribution Of Above To Concerned Officials After The Same Has Been Seen And Marked By The Authorities Concerned And Noting The Same In The Diary Register. 6. Assisting The Os / Udc In Typing Of Routine Letters, Notes, Etc. 7. Filing Letters In Respective Files And Docketing / Cross Referencing Them For Submission To Os / Udc / Higher Authorities. 8. Dispatch Of Mails / Letters After Recording The Details In The Despatch Register. 9. Submission Of Routine Reports And Returns. 10. Assist In Miscellaneous Office Functions. 10. He May Be Asked To Maintain Records. 11. He Can Be Given The Tasks To Type All Officials Letter In English And Hindi. 12. He May Be Asked To Send Emails, Receive Or Check E-Mails And Report To The Officer. 13. Regular Ldc Can Also Be Given Some Other Tasks Such As Taking Attendance, Printing Of Multiple Documents And Submitted To Particular Office Or Officer. 14. Ldc Is Also Required To Prepare Reports Sometimes. 15. Ensuring That The Store Is Kept Clean And Organized. 16. Must Be Organized And Punctual. 17. Well-Presented And Professional. 18. Prior Experience In The Field, Preferably In Store Management, Would Be Advantageous. 19. Excellent Verbal And Written Communication Skills. 20. Take Delivery Of All Incoming Materials And Reconcile With Purchase Orders. 21. Track, Document, And Resolve Any Discrepancies On Received Orders. 22. Ensure Accuracy Of The Facilitys Inventory System By Updating Records Of Physical Inventory Totals, Receipts, Adjustments, And Returns. 23. Manage Inventory / Supplies And Ensure They Are Within The Established Minimum And Maximum Levels. 24. Keep Up-To-Date Records Of Receipts, Records, And Withdrawals From The Stockroom. 25. Manage Supplier Relations And Database As Well As Maintain High Ethical Relationships Both Internally And Externally. 26. Create Purchase Orders And Utilize Purchasing Card To Perform Low-Value Procurement Activities, Scope Of Work Of Security Guards 1. The Company / Agency Shall Provide Security Personnel To The Vidyalaya Deploying Full Safe Security Measures, Providing Early Warning, And Mobilizing Troubleshooting Elements. The Items Or Situations That Have To Be Covered By Security Services Of The Company Are Enumerated Below:- A. Adhere To The Standard Operating Procedure [ Sops ) Given By The Authorities Of Nvs, If Any, Which May Be Modified From Time To Time. B. Protection Of Property And Personnel [ Faculty, Staff, Students, Official Visitors And Residents ] Of The Vidyalaya Against Wilful Harm; The Houses, Play Grounds, Buildings Etc All Within The Boundary Of Jnv Campus. C. Protection Of Property, Cash Documents And Personnel Of The Vidyalaya As And When So Specified. D. Protect Property / Cash / Documents / Equipment Of Vidyalaya Against Burglary [ Where Loss Is Due To Entry After Breaking Any Entry Lock / Door / Window / Grill. D. Regulate Access Control At Gates, Prevent Misuse Of Jnv Grounds And Facilities By Outsiders, Neighbouring Villages, Prevent Trespassing, Unauthorized Parking, Unauthorised Construction, Squatting In The Vidyalaya Campus By Unauthorised Persons. E. Prevent Loss On Account Of Lapse In The Security Services. . Assisting Fire Fighting Operations With Provided Equipment. F. Prevent Trespass In Specified Areas / Offices In The Vidyalaya. G. Regulate Parking Of Vehicles In Designated Areas Of The Vidyalaya. H. Provide Security During Official, Social And Religious Functions Inside The Jnv Campus. I. The Agency Shall Be Responsible For Opening / Closing Of The Dormitories And Academic Blocks As Necessitated / Directed By The Principal On Working And Closed Days, J. The Agency Shall Maintain Records Of Inward And Outward Movement Of Persons ( I.E. Jnv Employees, Guests And Visitors ) , Material And Vehicles Etc, With Proper Check On The Same As Per Instructions Of The Principal From Time To Time. All The Vehicles Should Be Physically Checked Thoroughly On Entry / Exit. K. The Security Personnel Deployed Shall Take Regular Rounds Of The Premises To Maintain Vigil And Alertness. L. Conduct Security Audits / Surveys / Investigations / Consultancies As Per Requirements. O. Conduct Periodical Training Of Security Guards Of Its Own. M. Carry Out Any Other Job Assigned By The Principal In The Interest Of Security Of The Vidyalaya, Scope Of Work Of Housekeeping 1. Housekeeping Work Should Undertake That They Will Perform Sweeping, Cleaning And Gardening Work Of The Academic Building, Hostels, Office, Mess Area, Store Rooms And Other Building / Areas Within Its Premises At Least Twice Or Need Basis In A Day. 2. Sweeping, And Cleaning Of The Entire Area And Surroundings Of The Campus And Collection Of All Waste Materials / Garbage And Disposal Of The Same As Per Instructions Of The Jnvs Authorities. 3. Cleaning Of The Floor Area With Wet Floor Dusters And Detergent / Disinfectants Etc. Regularly As Directed By The Authority. 4. Sanitization Of Dormitories, School Building, Mess, Office And Other Buildings As Directed By The Jnvs Authorities. 5. Cutting Of Bushes And Grasses Inside And Surroundings The Campus. 6. Spraying Of Flit / Anti Termite Treatment & Rodent Control Etc. Are To Be Made Regularly And Whenever Necessary For Keeping The Hostels, Mess, Classrooms, Office Etc. Free From Mosquitoes, Flies, Termite / Pests / Rats Etc. 7. Cleaning And Washing Of Toilets, Bathrooms And Urinals Using Deodorants, Detergent, Phenyls And Disinfectants Twice A Day And On Need Basis As Directed By The Jnvs Authorities. 8. Sweeping And Cleaning Of Sewer Line, Sewer Chambers Within And Surroundings The Vidyalaya Campus. 9. Sweeping And Cleaning Of Open Areas, Passage, Lawns, Within And Surroundings The Vidyalaya Campus. 10. Regular Dusting / Cleaning Of Rooms & Office Furniture ( Table And Chair ) And Equipments I.E. Fans, Electrical Fittings, Window Panes And Glass Cleaning, Telephones, Book Cases, Filing Cabinets, Amirahs And Doors And Removal Of Cobwebs Academic Building, Hostels, Office, Mess Area, Store Rooms And Other Building / Areas Every Day Or As Directed By The Competent Authority. 11. Gardening And Watering To Plants. 12. Engaged Personnel Will Behave In Decent Manners With Students And Staff Of The Vidyalaya 13. In Case Of Any Emergency, The Engaged Personnel Will Have To Inform The Principal / Vice- Principal / Os Immediately And Service Provider / Outsource Agency Also. 14. Other Works And Duties Assigned By The Jnv Authority, Scope Of Work Of Mess Helper 1. He Will Assist Cook. 2. He Will Look After The Mess Related To All Assigned Work During Duty Hours. 3. He Will Ensure Upkeep Of The Mess Premises I.E. Cleanliness Of The Mess And Surroundings Of The Mess Premises On Duty. 4. He Will Look After Mess Cleaning. 5. He Will Do The Work Of Cutting Vegetables And Preparation Of Roti. 6. He Will Work Under Cook And Supervision Of A Catering Assistant. 7. He Will Maintain Cordial Relations Between Students And All Senior Staff. 8. He Will Keep Himself Clean And Will Wear A Uniform All The Time. 9. He Should Demonstrate Sound Knowledge Of Proper Food Handling Procedures And Remove Expired Or Spoiled Ingredients From The Refrigerator, Freezer, And Stockroom. 10. He Should Be Able To Follow All Food Health And Safety Regulations And Display Exceptional Organizational Skills To Ensure The Timely Completion Of Kitchen Duties. 11. Preparing Meal Ingredients For The Cook, Which Includes Washing, Peeling, Cutting, And Slicing Ingredients. 12. Assisting Kitchen Staff To Unload Food Supplies From Delivery Trucks. 13. Properly Washing And Drying All Dishes, Utensils, Cooking Instruments And Cutting Boards. 14. Neatly Putting Away All Utensils, Cooking Instruments, Dishes, And Cutting Boards In Their Respective Places. 15. Removing Garbage, Replacing Garbage Bags, And Washing Garbage Cans. 16. Mopping And Sweeping The Kitchen Areas As Required. 17. Storing Ingredients And Food Items According To Food Safety Standards, Matron Scope Of Work Of Matron 1. She Will Stay In The Girl Dormitory During The Day When The Girls Are Away To Attend Classes And Other Curricular Activities. 2. She Will Take Care Of Girls Like A Foster Mother. 3. She Will Sleep With The Girls In The Dormitory During The Night. 4. She Will Ensure Unkeep Of The House Le, Cleanliness Of The Dorms, Toilets And Bathrooms And Surrounding With The Active Participation Of The Girls And The Sweeper On Duty. 4. She Will Check The Entry Of Any Man Or Unauthorized Persons In The House. 5. She Will Attend Any Girl Who Comes Back To The House During Class Activities And Knows Her Reason And Also Record It With Time. 6. She Will Liaison Between Ailing Girls And The Staff Nurse And If Need Be She Will Report Any Problem To The House Mistress And / Or The Principal. She Will Help The Calling Girls To Take Timely Medicines And Proper Diet As Prescribed By The Staff Nurse / Medical Officer. 7. She Will Provide Personal Care To The Ailing Girls To Comfort Them. 8. She Will Help Girls In Managing Their Natural Growth. 9. She Will See That All Girls Go To Classes And Other Activities In Time. 10. She Will Periodically Check The Furniture And Cots Etc., Particularly Those Items Made Of Steel And If Any Item Is Found Damaged Which Could Hurt A Child, She Will Bring It To The Notice Of The House Mistrsss / Principal For Its Repair / Replacement. 11. She Will Report Any Damaged Electrical Wiring / Fitting In The House To The House Mistress. 12. She Will Take Care Of Proper Water Supply In The House. 13. She Will Assist The House Mistress In Taking Overall Care Of The Girls To The Extent Possible. 14. She Will Maintain Very Cordial And Affectionate Interaction With The Girls From Time To Time To Know Their Personal Needs And Problems, If Any, And Counsel Them To Overcome Them. 15. She Will Lock The House In The Night And During Day Time When The Girls Are In The Class Or For Activities And Keep Keys With Her. 16. She Will Be A Keen Observer To Notice If Any Girl Students Are Upset Emotionally Or Subjected To Depression Etc, And Bring It To The Notice Of The House Mistress / Principal. 17. Any Other Work Related To Looking After The Girls In The House As Assigned By The Principal, Job Description For Personnel Engaging For Housekeeping 1 ) Outsourcing Agency Offering Personnel For Housekeeping Work Should Undertake That They Will Perform Sweeping, Cleaning And Gardening Work Of The Academic Building, Hostels, Office, Mess Area, Store Rooms And Other Building / Areas Within Its Premises At Least Twice Or Need Basis In A Day. 2 ) Sweeping And Cleaning Of Entire Area And Surroundings Of The Campus And Collection Of All Waste Materials / Garbage And Disposal Of The Same As Per Instructions Of The Jnvs Authorities. 3 ) Cleaning Of The Floor Area With Wet Floor Dusters And Detergent / Disinfectants Etc. Regularly As Directed By The Authority. 4 ) Sanitization Of Dormitories, School Building, Mess, Office And Other Building As Directed By The Jnvs Authorities. 5 ) Cutting Of Bushes And Grasses Inside And Surroundings The Campus. 6 ) Spraying Of Flit / Anti Termite Treatment & Rodent Control Etc. Are To Be Made Regularly And Whenever Necessary For Keeping The Hostels, Mess, Classrooms, Office Etc. Free From Mosquitoes, Flies, Termite / Pests / Rats Etc. 7 ) Cleaning And Washing Of Toilets, Bathrooms And Urinals Using Deodorants, Detergent, Phenyls And Disinfectants Twice A Day And On Need Basis As Directed By The Jnvs Authorities. 8 ) Sweeping And Cleaning Of Sewer Line, Sewer Chambers Within And Surroundings The Vidyalaya Campus. 9 ) Sweeping And Cleaning Of Open Areas, Passage, Lawns, Within And Surroundings The Vidyalaya Campus. 10 ) Regular Dusting / Cleaning Of Rooms & Office Furniture ( Table And Chair ) And Equipments I.E. Fans, Electrical Fittings, Window Panes And Glass Cleaning, Telephones, Book Cases, Filing Cabinets, Amirahs And Doors And Removal Of Cobwebs Academic Building, Hostels, Office, Mess Area, Store Rooms And Other Building / Areas Every Day Or As Directed By The Competent Authority. 11 ) Gardening And Watering To Plants. 12 ) Engaged Personnel Will Behave In Decent Manners With Students And Staff Of The Vidyalaya 13 ) In Case Of Any Emergency, The Engaged Personnel Will Have To Inform To The Principal / Viceprincipal / Os Immediately And Service Provider / Outsource Agency Also. 14 ) Other Works And Duties Assigned By The Jnv Authority, Scope Of Work Of Care Taker 1. He Will Assist House Master And Ahm. 2. He Will Look After The Boys’ Dormitory During The Assigned Duty Hours. 3. He Will Ensure Unkeep Of The House, I.E. Cleanliness Of The Dormitories, Toilets And Bathrooms And Surroundings With The Active Participation Of The Boys And The Sweeper On Duty. 4. He Will Check The Entry Of Any Man Or Unauthorized Person In The House. 5. He Will Attend Any Boy Who Comes Back To The House During Class Activities Hours And Know From Him Reason And Also Record It With Time.. 6. He Will Liaison Between Ailing Boys And The Staff Nurse And He Will Inform It To The House Master And / Or The Principal. 7. He Will Help The Ailing Boys For Taking Timely Their Medicines And Proper Diet As Prescribed By The Staff Nurse / Medical Officer. 8. He Will Provide Personal Nursing Care To The Ailing Boys And Comfort Them. 9. He Will See That All Boys Go To Classes And Other Activities In Time. 10. He Will Periodically Check The Furniture And Cots Etc. Particularly Those Items Made Of Ms Sheet And If Any Item Found Damaged, Which Could Hurt A Child, He Will Bring It To The Notice Of The House Master / Principal For Its Repair / Replacement. 11. He Will See That There Is No Damaged Electrical Wiring / Fitting In The House. 12. He Will Take Care Of Proper Water Supply In The House. 13. He Will Assist House Master In Taking Overall Care Of The Boys To The Extent Possible. 14. He Will Have Very Cordial And Affectionate Interaction With The Boys From Time To Time To Know To Their Personal Needs And Problems If Any And Help Them Overcome Them. 15. He Will Lock The House In The Night And During Day Time When The Boys Are In The Class Or For Activities And Keep Keys With Him. 16. He Will Be Keen Observer To Notice If Any Boy Student Is Upset Emotionally Or Subjected To Depression Etc. And Bring It To The Notice Of The House Master / Principal. 17. The Principal Will Assign The Duty Of The Boys Dormitories As Mentioned Above To Chowkidar-Cumsweeper And Chowkidar In Such A Way That They Look After The Assigned Work Round The Clock. 18. A Register Regarding Change Of The Shift Duty Of This Staff And Proper Handing / Taking Over The Charge After Completion Of The Shift Duty / Before Start Of Shift Duty Shall Be Maintained. 19. Any Other Work Mainly Related To Looking After The Boys In The House As Assigned By The Principal, Matron Scope Of Work Of Matron 1. She Will Take Care Of Girls Like A Foster Mother. 2. She Will Stay In The Girl Dormitory During Day When The Girls Are Away To Attend Classes And Other Cocurricular Activities. 3. She Will Sleep With The Girls In The Dormitory During The Night. 4. She Will Ensure Unkeep Of The House I.E., Cleanliness Of The Dorms, Toilets And Bathrooms And Surrounding With The Active Participation Of The Girls And The Sweeper On Duty. 5. She Will Check The Entry Of Any Man Or Unauthorized Persons In The House. 6. She Will Attend Any Girl Who Comes Back To The House During Class Activities House And Know From Her Reason And Also Record It With Time. 7. She Will Liaison Between Ailing Girls And The Staff Nurse And If Need Be She Will Report Any Problem To The House Mistress And / Or The Principal. 8. She Will Help The Ailing Girls For Taking Timely Medicines And Proper Diet As Prescribed By The Staff Nurse / Medical Officer. 9. She Will Provide Personal Care To The Ailing Girls To Comfort Them. 10. She Will Help Girls In Managing Their Natural Growth. 11. She Will See That All Girls Go To Classes And Other Activities In Time. 12. She Will Periodically Check The Furniture And Cots Etc., Particularly Those Items Made Of Steel And If Any Item Is Found Damaged Which Could Hurt A Child, She Will Bring It To The Notice Of The House Mistrsss / Principal For Its Repair / Replacement. 13. She Will Report Any Damaged Electrical Wiring / Fitting In The House To The House Mistress. 14. She Will Take Care Of Proper Water Supply In The House. 15. She Will Assist House Mistress In Taking Overall Care Of The Girls To The Extent Possible. 16. She Will Maintain Very Cordial And Affectionate Interaction With The Girls From Time To Time To Know Their Personal Needs And Problems, If Any, And Counsel Them To Overcome Them. 17. She Will Lock The House In The Night And During Day Time When The Girls Are In The Class Or For Activities And Keep Keys With Her. 18. She Will Be Keen Observer To Notice If Any Girl Students Are Upset Emotionally Or Subjected To Depression Etc. And Bring It To The Notice Of The House Mistress / Principal. 19. Any Other Work Related To Looking After The Girls In The House As Assigned By The Principal, Scope Of Work Of Mess Helper 1. He Will Assist To Cook. 2. He Will Look After The Mess Related All Assigned Work During Duty Hours. 3. He Will Ensure Unkeep Of The Mess Premises I.E. Cleanliness Of The Mess And Surroundings Of The Mess Premises On Duty. 4. He Will Look After Mess Cleaning. 5. He Will Do The Work Of Cutting Vegetables And Preparation Of Roti. 6. He Will Work Under Cook And Supervision Of Catering Assistant. 7. He Will Maintain Cordial Relation Between Students And All Senior Staff. 8. He Will Keep Himself Clean And Will Wear Uniform All The Time. 9. He Should Demonstrate Sound Knowledge Of Proper Food Handling Procedures And Remove Expired Or Spoiled Ingredients From The Refrigerator, Freezer, And Stockroom. 10. He Should Be Able To Follow All Food Health And Safety Regulations And Display Exceptional Organizational Skills To Ensure The Timely Completion Of Kitchen Duties. 11. Preparing Meal Ingredients For The Cook, Which Includes Washing, Peeling, Cutting, And Slicing Ingredients. 12. Assisting Kitchen Staff To Unload Food Supplies From Delivery Trucks. 13. Properly Washing And Drying All Dishes, Utensils, Cooking Instruments And Cutting Boards. 14. Neatly Putting Away All Utensils, Cooking Instruments, Dishes, And Cutting Boards In Their Respective Places. 15. Removing Garbage, Replacing Garbage Bags, And Washing Garbage Cans. 16. Mopping And Sweeping The Kitchen Areas As Required. 17. Storing Ingredients And Food Items According To Food Safety Standards.---- Total Quantity :
Contract Date: Ref. Documents Contract Value : 80.27 Lakh
Government Departments No of Bidders 5
49.
Educational and Research Institute #4407571 AOC
Bids Are Invited For Custom Bid For Services - for manpower outsourcing agency - Security Guard (Without Arm) House Keeping Matron Caretaker Assistant Cook Helper- CLERICAL WORK 1. Daily office work and day to day operation in the office under the supervision of higher authority. 2. Maintain the data, files and documents of the office in the prescribed system and accurate place. 3. Maintain an attendance register of all officials as directed by the competent authority and their leaves records. 4. Diarising the letters/communications/e-mail and files received. 5. Distribution of above to concerned officials after the same has been seen and marked by the authorities concerned and noting the same in the Diary register. 6. Assisting the OS/UDC in typing of routine letters, notes, etc. 7. Filing letters in respective files and docketing/ cross referencing them for submission to OS/UDC/Higher authorities. 8. Dispatch of mails/letters after recording the details in the Despatch Register. 9. Submission of routine reports and returns. 10. Assist in miscellaneous office functions. 10. He may be asked to maintain records. 11. He can be given the tasks to type all officials letter in English and Hindi. 12. He may be asked to send emails, receive or check e-mails and report to the officer. 13. Regular LDC can also be given some other tasks such as Taking Attendance, Printing of Multiple Documents and submitted to Particular Office or Officer. 14. LDC is also required to Prepare Reports sometimes. 15. Ensuring that the store is kept clean and organized. 16. Must be organized and punctual. 17. Well-presented and professional. 18. Prior experience in the field, preferably in store management, would be advantageous. 19. Excellent verbal and written communication skills. 20. Take delivery of all incoming materials and reconcile with purchase orders. 21. Track, document, and resolve any discrepancies on received orders. 22. Ensure accuracy of the facilitys inventory system by updating records of physical inventory totals, receipts, adjustments, and returns. 23. Manage inventory/supplies and ensure they are within the established minimum and maximum levels. 24. Keep up-to-date records of receipts, records, and withdrawals from the stockroom. 25. Manage supplier relations and database as well as maintain high ethical relationships both internally and externally. 26. Create purchase orders and utilize purchasing card to perform low-value procurement activities. - SCOPE OF WORK OF SECURITY GUARDS 1. The Company/Agency shall provide security personnel to the Vidyalaya deploying full safe Security measures, providing early warning, and mobilizing troubleshooting elements. The items or situations that have to be covered by security services of the company are enumerated below:- a. Adhere to the Standard Operating Procedure [SOPs) given by the authorities of NVS, if any, which may be modified from time to time. b. Protection of property and personnel [faculty, staff, students, official visitors and residents] of the vidyalaya against wilful harm; the Houses, Play grounds, buildings etc all within the boundary of JNV campus. c. Protection of property, cash documents and personnel of the Vidyalaya as and when so specified. d. Protect property/cash/documents/equipment of vidyalaya against burglary [where loss is due to entry after breaking any entry lock/door/window/grill. d. Regulate access control at gates, prevent misuse of JNV grounds and facilities by outsiders, neighbouring villages, prevent trespassing, unauthorized parking, unauthorised construction, squatting in the Vidyalaya campus by unauthorised persons. e. Prevent loss on account of lapse in the security services. . Assisting fire fighting operations with provided equipment. f. Prevent trespass in specified areas/offices in the Vidyalaya. g. Regulate parking of vehicles in designated areas of the Vidyalaya. h. Provide security during official, social and religious functions inside the JNV Campus. i. The agency shall be responsible for opening/closing of the dormitories and academic blocks as necessitated/directed by the Principal on working and closed days, j. The Agency shall maintain records of inward and outward movement of persons (i.e. JNV Employees, guests and visitors), material and vehicles etc, with proper check on the same as per Instructions of the Principal from time to time. All the vehicles should be physically checked thoroughly on Entry/Exit. k. The security personnel deployed shall take regular rounds of the premises to maintain vigil and alertness. l. Conduct security audits/surveys/investigations/consultancies as per requirements. o. Conduct periodical training of security guards of its own. m. Carry out any other job assigned by the Principal in the interest of Security of the Vidyalaya.- SCOPE OF WORK OF HOUSEKEEPING 1. Housekeeping work should undertake that they will perform sweeping, cleaning and gardening work of the Academic Building, Hostels, Office, Mess area, store rooms and other building/areas within its premises at least twice or need basis in a day. 2. Sweeping, and cleaning of the entire area and surroundings of the campus and collection of all waste materials/garbage and disposal of the same as per instructions of the JNVs authorities. 3. Cleaning of the floor area with wet floor dusters and detergent/ disinfectants etc. regularly as directed by the authority. 4. Sanitization of dormitories, school building, Mess, Office and other buildings as directed by the JNVs authorities. 5. Cutting of bushes and grasses inside and surroundings the campus. 6. Spraying of flit/anti termite treatment & rodent control etc. are to be made regularly and whenever necessary for keeping the hostels, mess, classrooms, Office etc. free from mosquitoes, flies, termite/pests/rats etc. 7. Cleaning and washing of toilets, bathrooms and urinals using deodorants, detergent, Phenyls and disinfectants twice a day and on need basis as directed by the JNVs authorities. 8. Sweeping and cleaning of Sewer line, sewer chambers within and surroundings the Vidyalaya campus. 9. Sweeping and cleaning of open areas, passage, lawns, within and surroundings the Vidyalaya campus. 10. Regular dusting/cleaning of rooms & office furniture (Table and chair) and equipments i.e. Fans, electrical fittings, window panes and glass cleaning, telephones, book cases, filing cabinets, Amirahs and doors and removal of cobwebs Academic Building, Hostels, Office, Mess area, store rooms and other building/areas every day or as directed by the competent authority. 11. Gardening and watering to plants. 12. Engaged personnel will behave in decent manners with students and staff of the Vidyalaya 13. In case of any emergency, the engaged personnel will have to inform the Principal/Vice- Principal/OS immediately and Service Provider/Outsource Agency also. 14. Other works and duties assigned by the JNV Authority- SCOPE OF WORK OF MESS HELPER 1. He will assist Cook. 2. He will look after the mess related to all assigned work during duty hours. 3. He will ensure upkeep of the mess premises i.e. cleanliness of the mess and surroundings of the mess premises on duty. 4. He will look after Mess Cleaning. 5. He will do the work of cutting vegetables and preparation of roti. 6. He will work under Cook and supervision of a Catering assistant. 7. He will maintain cordial relations between students and all senior staff. 8. He will keep himself Clean and will wear a uniform all the time. 9. He should demonstrate sound knowledge of proper food handling procedures and remove expired or spoiled ingredients from the refrigerator, freezer, and stockroom. 10. He should be able to follow all food health and safety regulations and display exceptional organizational skills to ensure the timely completion of kitchen duties. 11. Preparing meal ingredients for the cook, which includes washing, peeling, cutting, and slicing ingredients. 12. Assisting kitchen staff to unload food supplies from delivery trucks. 13. Properly washing and drying all dishes, utensils, cooking instruments and cutting boards. 14. Neatly putting away all utensils, cooking instruments, dishes, and cutting boards in their respective places. 15. Removing garbage, replacing garbage bags, and washing garbage cans. 16. Mopping and sweeping the kitchen areas as required. 17. Storing ingredients and food items according to food safety standards. MATRON SCOPE OF WORK OF MATRON 1. She will stay in the girl dormitory during the day when the girls are away to attend classes and other curricular activities. 2. She will take care of girls like a foster mother. 3. She will sleep with the girls in the dormitory during the night. 4. She will ensure unkeep of the house Le, cleanliness of the dorms, toilets and bathrooms and surrounding with the active participation of the girls and the sweeper on duty. 4. She will check the entry of any man or unauthorized persons in the house. 5. She will attend any girl who comes back to the house during class activities and knows her reason and also record it with time. 6. She will liaison between ailing girls and the Staff Nurse and if need be she will report any problem to the house mistress and/or the Principal. She will help the calling girls to take timely medicines and proper diet as prescribed by the staff nurse/medical officer. 7. She will provide personal care to the ailing girls to comfort them. 8. She will help girls in managing their natural growth. 9. She will see that all girls go to classes and other activities in time. 10. She will periodically check the furniture and cots etc., particularly those items made of steel and if any item is found damaged which could hurt a child, she will bring it to the notice of the house mistrsss/Principal for its repair/replacement. 11. She will report any damaged electrical wiring/fitting in the house to the House Mistress. 12. She will take care of proper water supply in the house. 13. She will assist the house mistress in taking overall care of the girls to the extent possible. 14. She will maintain very cordial and affectionate interaction with the girls from time to time to know their personal needs and problems, if any, and counsel them to overcome them. 15. She will lock the house in the night and during day time when the girls are in the class or for activities and keep keys with her. 16. She will be a keen observer to notice if any girl students are upset emotionally or subjected to depression etc, and bring it to the notice of the House Mistress/Principal. 17. Any other work related to looking after the girls in the house as assigned by the Principal Total Quantity :
Contract Date: Ref. Documents Contract Value : 52.75 Lakh
Government Departments No of Bidders 3
TenderDetail
Loading tenders