View Bid Results For Anchor Setting Tool Tenders

We found 230 Bid Results related to anchor setting tool tenders. You can find Contractor details who won anchor setting tool tenders along with contract details in Bid awards announcements section.

Filters
Stage
126
64
40
Tender Publishing Platform
15
215
State / UT
24
41
30
26
23
19
14
13
8
6
6
6
5
5
4
4
3
3
3
3
2
2
2
1
1
Contract Value
106
9
56
57
Publish Date
0
0
0
0
0
Sector
26
58
36
27
18
16
14
11
11
6
6
5
3
3
2
2
2
1
1
1
1
1
1
1
1
1
1
Ownership
5
117
41
37
31
4
Within keyword
Active filters:
Showing 1–5 of 230 tenders matching your filters
1.
Petroleum and Natural Gas #11322090 AOC
Bids Are invited for Custom Bid For Services - Construction Of Compressor Shed With Associated Civil And Electrical Works For Operation Of Two Nos Screw Type Air Compressor At Ihb Mithirohar Pumping Station In Gujarat - Earth Work In Excavation By Mechanical Means (Hydraulic Excavator)/ Manual Means Over Areas Including Dressing Of Sides And Ramming Of Bottoms Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soil, All Works Up To Any Lead And Lift, As Directed By The Engineer-In Charge : In All Kinds Of Soil. , Demolishing Cement Concrete Manually/ By Mechanical Means Including Disposal Of Material Within 50 Metres Lead As Per Direction Of The Engineer-In-Charge. [Notes: (1) Dismantling Shall Be Allowed During Day Shift Only & Prior Permission For The Same Shall Be Obtained. (2) Providing Of Necessary Covers/ Barricades Around The Work Area Shall Be Done Prior To Dismantling Operations.]Nominal Concrete 1:4:8 Or Leaner Mix. , Supplying & Fixing Welded Wire Mesh Door Made From Steel Wire Fabric Of Rectangular Mesh 75 X 25 Mm Size, Weight Not Less Than 7.75 Kg/Sqm Fixed On Angle Iron Frame By Welding, Fixing Of Holdfast, Hinges, Door Handles, Tower Bolts, Aldrops (2 Nos.), Wheels, Painting With Two Coats Of Synthetic Enamel Paint Of Over A Coat Of Red Oxide Zinc Chrome Primer, Excluding Frame Etc. Complete In All Respects Inclusive Of Cost Of All Labour, Materials, Tools, Tackles Etc. As Per Drawings, Specifications And Directions Of The Engineer-In-Charge. (Note: Angle Iron Frame Shall Be Paid Separately). , Providing And Laying In Position Cement Concrete Of Specified Grade Including The Cost Of Centering And Shuttering - All Work Up To Plinth Level : 1:4:8 (1 Cement : 4 Coarse Sand (Zone-Iii) : 8 Graded Stone Aggregate 40 Mm Nominal Size) , Providing And Laying In Position Ready Mixed Or Site Batched Design Mix Cementconcrete For Reinforced Cement Concrete Work;Using Coarse Aggregate And Fine Aggregate Derived From Natural Sources,Portland Pozzolana /Ordinary Portland/Portland Slag Cement,Admixtures In Recommended Proportions As Per Is:9103 To Accelerate /Retard Setting Of Concrete, To Improve Durability And Workability Without Impairing Strength;Including Pumping Of Concrete To Site Of Laying, The Cost Of Centering, Shuttering,Finishing, Curing,Carriage For All Leads,As Per Direction Of The Engineer-In-Charge,For The Following Grades Of Concrete.:Note: 1. Extra Cement Up To 10% Of The Minimum Specified Cement Content In Design Mix Shall Be Payable Separately. Incase The Cement Content In Design Mix Is More Than 110% Of The Specified Minimum Cement Content, The Contractor Shall Have Discretion To Either Re-Design The Mix Or Bearthe Cost Of Extracement. 2.Payment For Reinforcement Shall Be Made As Per Relevant Item Of Sor. ;All Works Upto Plinth Level ; Concrete Of M30 Grade With Minimum Cement Content Of 350 Kg /Cum , Supplying, Cutting,Bending, Hoisting,Placing In Position Withproper Pre-Castconcrete Block Coverand Binding By Pvc Coated (Extrusion Process) 18 Guage Swgwire, High Yield Strengthdeformed Bars Of Grade Fe500 Conforming To Is:1786 With Protectivefusion Epoxy Coating Asper Is:13620 For All R.C.C Works Including All Necessary Handling At All Heights And Depths Complete In All Respects As Per Specifications And Directions Of The Engineer-In-Charge. , Brick Work With Common Burnt Clay F.P.S. (Non Modular)Bricks Of Class Designation 7.5 Infoundation And Plinth In : Cement Mortar 1:6 (1Cement : 6 Coarse Sand) , 15 Mm Cement Plaster On The Rough Side Of Single Or Half Brickwall Of Mix : 1:6 (1 Cement : 6 Fine Sand) , 6 Mm Cement Plaster Of Mix 1:3 (1 Cement : 3 Fine Sand) , Supplying, Fabricating, Erecting, Placing And Fixing In Position M.S. Structural Works Using Rolled/ Built Up Sections For Truss, Claddings, Bracings, Purlins, Supporting Frames Made Of Joists, Tubes, Pipes, Channels, Angles, Plates, Flats, Bars Etc. Including Cutting To Required Size Welding Of Joints, Fixing Anchor Plates, Including Bolts, Theading, Nuts, Washers, Sleeves Etc. Including Preparation Of Detailed Fabrication Drawings & Submission To The Engineer-In-Charge For Approval Before Start Of Fabrication, Supplying & Applying Painting With Two Coats Of Epoxy Paint Epilux 155 High Build Enamel Over A Coat Of Epilux 610 Primer Of M/S Berger Or Any Other Approved Equivalent Make As Per Manufacturers Recommendation, Complete In All Respects Inclusive Of Cost Of All Labour, Materials, Tools, Tackles Etc. As Per Drawings, Specifications And Directions Of The Engineer-In-Charge. (Excluding The Cost Of Concrete Work). , Providing And Laying 52 Mm Thick Cement Concrete Flooring With Metallic Hardner, Under Layer Of 37 Mm Thick Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size) And Top Layer Of 15 Mm Thick Metallic Concrete Hardner Consis Ting Of Mix 1:2 (1 Cement : 2 Stone Aggregate 6 Mm Nominal Size) By Volume With Which Metallic Hardening Compound Such As Ironite No . 1 Of Ironite Co. Of India Ltd. Or Aproved Equivalent Mixed In The Ratio 4:1 (4 Parts Of Cement : 1 Part Of Metallic Floor Hardenin G Compound Of Approval Quality) By Weight, Inclusive Of Cost Of Finishing, Labour, Material, Equipment, Etc. As Per Specifications A Nd Directions Of The Engineer-In-Charge. , Supplying And Filling In Plinth With Sand Under Floors, Including Watering, Ramming, Consolidating And Dressing Complete. , Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level :1:3:6 (1 Cement : 3 Coarse Sand (Zone-Iii) : 6 Graded Stone Aggregate 40 Mm Nominal Size) , Supplying And Layingflat Brick Soling Infoundation Trench, Infloors, Garages, Sumps,Etc., With Bricks Of Classdesignation 50 Laid Toproper Slope, Level Andgrade Etc. Filling Of Thejoints With Sand Etc.Complete In All Respectsinclusive Of Cost Of Alllabour, Materials, Tools,Tackles Etc. As Perdrawings, Specificationsand Directions Of Theengineer-
Contract Date: Ref. Documents Contract Value : 24.99 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 5
2.
Power #11267487 Technical Bid
Tender for Rate Contract For Procurement Of Material In Respect Of Std Ganderbal For The Year 2026-27 Or Till Next Stage Contract Is Finalized , Procurement Of Material In Respect Of Std Ganderbal For The Year 2025-26 Or Till Next Stage Contract Is Finalized , 11 Kv Horn Gap Fuse Set 3 Phase 200A , 11Kv Link Rods For 11Kv Link Set 22 Feet Long With Insulating Bottom Grip Bamboo/Carbon Fibre , Gapless Surge Arrestor,9 Kv ,10 Ka ,La With Polymer Housing, Stn. Type , 11 Kv Isolator, Double Break,3-Pole, 600Amp, Horizontal Mounting Type, With Earth Switch Complete Including Clamps And Fittings , 11 Kv 3-Core Current Transformer 800-400/5-5A,( Metering, Protection, Differential Core) , 11 Kv 3-Core Current Transformer 750-375/5-5A,( Metering, Protection, Differential Core) , 11 Kv 3-Core Current Transformer 600-300/5-5 A, ( Metering, Protection, Differential Core) , 11 Kv 2-Core Current Transformer 600-300/5-5 A, ( Metering, Protection) , 11 Kv 2-Core Current Transformer 400-200/5-5 A, ( Metering, Protection) , 11 Kv 2-Core Current Transformer 100-50/5-5 A, ( Metering, Protection) , 11 Kv 2-Core Current Transformer 50-25/5-5 A, ( Metering, Protection) , 11 Kv 2-Core Current Transformer 20-10/5-5 A, ( Metering, Protection) , 11 Kv Potential Transformer 110V, Accuracy Class 0.5 , Tension Fittings For 0.1 Acsr Conductor 70Kn , Tension Fittings For 0.15 Acsr Conductor 70 Kn , Tension Fittings For 0.2 Acsr Conductor 120 Kn , 185 Sqmm, 3Core , 11 Kv Cable Kit Indoor Type(Make-3M/ Polycab/ Anchor/ Havells/ Gloster Or Equivalent) , 185 Sqmm, 3 Core ,11 Kv Cable Kit Outdoor Type(Make-3M/ Polycab/ Anchor/ Havells/ Gloster Or Equivalent) , 240 Sqmm, 3 Core,11 Kv Cable Kit Indoor Type(Make-3M/ Polycab/ Anchor/ Havells/ Gloster Or Equivalent) , 240 Sqmm, 3 Core,11 Kv Cable Kit Outdoor Type(Make-3M/ Polycab/ Anchor/ Havells/ Gloster Or Equivalent) , 300 Sqmm, 3 Core, 11 Kv Cable Kit Indoor Type(Make-3M/ Polycab/ Anchor/ Havells/ Gloster Or Equivalent) , 300 Sqmm, 3 Core 11 Kv Cable Kit Outdoor Type(Make-3M/ Polycab/ Anchor/ Havells/ Gloster Or Equivalent) , 400 Sqmm, 3 Core 11 Kv Cable Kit Indoor Type(Make-3M/ Polycab/ Anchor/ Havells/ Gloster Or Equivalent) , 400 Sqmm, 3 Core 11 Kv Cable Kit Outdoor Type(Make-3M/ Polycab/ Anchor/ Havells/ Gloster Or Equivalent) , 630 Sqmm, Single Core 11 Kv Cable Kit Indoor Type(Make-3M/ Polycab/ Anchor/ Havells/ Gloster Or Equivalent) , 630 Sqmm, Single Core 11 Kv Cable Kit Outdoor Type(Make-3M/ Polycab/ Anchor/ Havells/ Gloster Or Equivalent) , 185 Sqmm, 11 Kv 3 Core Xlpe Cable Armoured (Make-3M/ Polycab/ Anchor/ Havells/ Gloster) , 240 Sqmm, 11 Kv 3 Core Xlpe Cable Armoured (Make-3M/ Polycab/ Anchor/ Havells/ Gloster) , 300 Sqmm, 11 Kv 3 Core Xlpe Cable Armoured (Make-3M/ Polycab/ Anchor/ Havells/ Gloster) , 400 Sqmm, 11 Kv 3 Core Xlpe Cable Armoured (Make-3M/ Polycab/ Anchor/ Havells/ Gloster) , 120 Sqmm, 3 Core 33 Kv Cable Kit Outdoor Type(Make-3M/ Polycab/ Anchor/ Havells/ Gloster Or Equivalent) , 300 Sqmm, 3 Core 33 Kv Cable Kit Outdoor Type(Make-3M/ Polycab/ Anchor/ Havells/ Gloster Or Equivalent) , 400 Sqmm, 3 Core 33 Kv Cable Kit Outdoor Type(Make-3M/ Polycab/ Anchor/ Havells/ Gloster Or Equivalent) , 120 Sqmm, 33 Kv 3 Core Xlpe Cable(Make-3M/ Polycab/ Anchor/ Havells/ Gloster) , 300 Sqmm, 33 Kv 3 Core Xlpe Cable(Make-3M/ Polycab/ Anchor/ Havells/ Gloster) , 400 Sqmm, 33 Kv 3 Core Xlpe Cable(Make-3M/ Polycab/ Anchor/ Havells/ Gloster) , 11 Kv 630 Mm² Single Core Xlpe Cable Armoured, Frls (Make-3M/ Polycab/ Anchor/ Havells/ Gloster) , Tripping And Closing Coils Must Have Burden Between 250 To 350 Watts At 30V Dc With Housing , Tripping Coil Of 11Kv Alind Make Vcb , Tripping Coil Of 11 Kv Er/Vijai Make Vcb , Tripping Coil Of 11Kv Electric Field Make Vcb , Tripping Coil Of 11Kv Abb Make Vcb , Tripping Coil Of 11Kv Crompton Make Vcb , Tripping Coil Of 11Kv Stelmac Make Vcb , Tripping Coil Of 11Kv Sudhir/Schneider Make Vcb , Tripping Coil Of 11Kv Pascal Make Vcb , Closing Coil Of 11Kv Alind Make Vcb , Closing Coil Of 11 Kv Er/Vijai Make Vcb , Closing Coil Of 11Kv Electric Field Make Vcb , Closing Coil Of 11Kv Abb Make Vcb , Closing Coil Of 11Kv Crompton Make Vcb , Closing Coil Of 11Kv Stelmac Make Vcb , Closing Coil Of 11Kv Sudhir/Schneider Make Vcb , Closing Coil Of 11Kv Pascal Make Vcb , 33 Kv Link Set Heavy Duty- Post Type, 800A Complete , 33Kv Link Rods Fibre/Bamboo Oil Impregnated With Insulated Bottom Grip 30 Feet Long , 33Kv Polymeric Composite Disc Insulator 36Kv,Min Failing Load 70Kn, Lighting Impulse 170Kv Positive And 180Kv Negative, Creepage Distance 900Mm. , 33Kv Polymeric Composite Pin Insulator 36Kv, 10Kn, Lighting Impulse 170Kv Positive And 180Kv Negative, Creepage Distance 900Mm.Type A , 33Kv Polymeric Composite Pin Insulator 36Kv, 10Kn, Lighting Impulse 170Kv Positive And 180Kv Negative, Creepage Distance 900Mm.Type B For 0.2 Acsr Conductor , 30 Kv Lightening Arrestor Set, 10 Ka, Station Class, Zno, Polymer Gap Less (Set Consists Of 03 No.) With All Accessories Required For Installation. , 33 Kv Isolator Without Earthing Blade (36 Kv, 1250 A, Outdoor, 3 Poles, 25 Ka) Porcelain (Set Consist Of 03 Limb) With All Accessories Required For Installation , 33 Kv Isolator With Earthing Blade (36 Kv, 1250 A, Outdoor, 3 Poles, 25 Ka) Porcelain (Set Consist Of 03 Limb) With All Accessories Required For Installation , 33 Kv Current Transformer (33 Kv, 1Φ, Multi Ratio Multi Core, Outdoor) (1 No. Per Φ) 3-Core, 0.5 5P10, Ps-Class 3 Core- With All Accessories Required For Installation , 400-200/5-5 A (Metering, Protection And Differential Core ) , 250-125/5-5 A (Metering, Protection And Differential Core ) , 33 Kv Voltage Transformer (33 Kv/110 V, 1Φ, Multi-Core, Outdoor), (1No. Per Φ) With All Accessories Required For Installation , Tripping Coil Of 33 Kv Vcb With Metallic Housing (Crompton, Alind, Alstom, Bhel, Abb) , Closing Coil Of 33 Kv Vcb With Metallic Housing (Crompton, Alind, Alstom, Bhel, Abb, Stelmac Etc ) , 33 Kv Polymer Post Insulator 36Kv,170Kv Impulse, Creepage Distance 1224M , Earthing Complete (Spike Earthing Rod 20Mm,2.5 Mtr Long) , Galvanised Earthing Strips 50X6 Mm/ 25X3mm , Galvanised Nuts & Bolts Of Different Sizes And Sorts , Pg Clamps For 0.1 Acsr Conductor 400A Pressure Di-Cast , Pg Clamps For 0.15 Acsr Conductor 500A Pressure Di-Cast , Pg Clamps For 0.2 Acsr Conductor 630A Pressure Di-Cast , Prefabricated Galvanised Channel Iron/ Angle Iron Of Different Sorts As Required , Prefabricated Galvanised Flat Iron Of Sorts 50/25 8/6Mm Thick , Instrument, Tools And Other Equipments , Alumunium Ladder 2*20 (Double Ladder) 3 Mm Thick With Sliding Mechanism , Bamboo Ladder 25 Long , 12V/7Ah Led Handheld Searchlight (Andslite/Philipls/Microtech,Fos) , Tool Kit Of Suitable Size With Tools ( Stanley / Taparia/Jon/Jk/ Make) Comprising Of :- Double End Spanners With Increases Or Decreased Sized Ends And D/Ring Type Following Sizes And Numbers Spanners 6-0, 7-8, 9-9-10, 10-11, 11-12, 12-13, 14-15, 16-17, 18-19, 20-21, 20-22, 24-27, 25-28, 30-32, Complete Set Cushion Grip, Pipe Wrench 12 Inch 1 No. 24 Inch 1 No., 12 Adjustable Chrome Plated Wrench, 8 Combination Plier Line Man Plier, 8 Long Nose Plier Length Nose Plier, 9 Crimping Plier Set, 230Mm-, 7 Length Cutting Plier, Hex Key(Ln Key) Set 11Pc Metric (1.5, 2, 2.5, 3, 4, 5,5.5, 6, 8, 10Mm 12Mm), 27Pc-1/2 Sq. Dr 12Pt Socket Set ( Comprising Of ) 20 Pc :- 1/2 Drive 12 Point Sockets: 10,11,12,13,14,15,16,17,18,19,20,21,22,23,24,25,26,27,30,32Mm 6 Pc :- 1/2 Drive Accessories : 2 Pc Extension Bar: 5 And 10(125 And 250Mm) Universal Joint, 1 Pc :- Spark Plug Socket 6 Point 13/16, 1 Pc Sliding T-Bar 10(254Mm); 1 Pc Flip-Drive Rachet., 1/4 Torque Rench, 914Mm , 36 Inch Bolt Cutter (Taparia Make, 12 Hacksaw Frame With 12 No. Spare Blades, Steel Body Retactable Utility Knife With 12 No. Spare Knives, 12H 340Gms Ball Pien Hammer Wooden Handle, 16 900Gms Ball Pien Hammer Wooden Handle, 5 Mtr Measuring Tape, Cold Chesel 7/8 (22Mm), Centre Punch 8Mm (15/16 )X 115Mm(4 1/2 ), Good Quality Multi Meter ( Fluke, Motwane, Meggar Make ) Capable Of Measuring Current From Mili Amps To 400A, Voltage Ac-Dc Ranging From Milli Volts To 750 Volts Wired/Clamp On Type, Capacitance, Resistance Ranging From Mill Ohms To Mega Ohms, With Continuity And Diode Testing Options. 24 Magnetic Torpedo/ Beam Level (3Vails) 300Mm -1 No. & 600Mm -1No., Files Flat/Round Type 8-12 Inch Long, Srew Driver Set Comprising Of 12 No.S Long Shank Having Star/Flat Type Tips With Heavy Duty Tefon Grips , Hv Detectors For All Voltages. (With Fiber Rod Telescopic) , Pliers (Make-Taparia/Stanley) , 11 Kv Hand Gloves ( Make 3M/ Crystal) , Earth Resistivity Tester (0-1000 Ohms) (Make-Motwane/Megger/ Fluke/Markoni) With Auto-Manual Options , Digital Insulation Resistance Tester 5000V (Make-Sonel/Megger/ Fluke/Equivalent) , 10 Feet A Type Ladder , Portable Welding Set , Portable Blue Lamp(Gas) , Portable Blue Lamp (Kerosene) , Insulation Tester And Continuity Tester 2.5 Kv Withvarious Kits (Make- Fluke/ Megger/Equivalent) , Clamp Meter/ Multi Meter ( Fluke, Motwane, Meggar/Meeca Make ) Capable Of Measuring Current From Mili Amps To 400A, Voltage Ac-Dc Ranging From Milli Volts To 750 Volts Wired/Clamp On Type, Capacitance, Resistance Ranging From Mill Ohms To Mega Ohms, With Continuity And Diode Testing Options. , Heavy Duty Pulling & Lifting Machine 5 Mt , Control Relays With 3Oc+1Ef 2 Element Based Digital Of Following Make. , Mit- 114/104 (Er) Make. , Lnt M314a , Schneider , Simens 7Sr , Crompton 14C , Crompton 14Cn , Ashida 131A , Ashida 141 A/B , Ashida Adr241a , Ashida Adr242b , Abb Ref 615 , High Speed Master Relay With 12-63Vdc, 12-220 Vac Coil And 4 No+4Nc Driver Contacts , Battery Bank 30 V,100 Ah , Of 15 No. Cells Of 2 V Each, Sealed Maintenance Free Vrla Type,High Impact Polyprophelene Copolymer Container,Flame Retardant (Exide/Amaron/Shoto/Hbl Make) , Battery Bank 36 V, 150 Ah Ultra Low Maintenance Tubular Battery Bank Compromising Of 3 No. Batteries Each Of 12 Volt (Hbl/Exide/Amaron/Luminous) , Battery Charger 36V, 40/60A With Full Wave Power Diode/Scr Based Recetification And Ripple Filtration. Avr Based Semi Digital With Inbuilt Autotransformer/Variant And Auto Manual Mode Having Digtal Precision Type/ Measuring Instruments, Led Type Indication, Inbuilt Buzzer/ Hoter Alarm During Technical Snags. The Charger Operating Ranges Must Be From 110V To 260 Vac Input Without Attoring Dc Output Through Smps , 7.5 Kva Servo Stablizer Copper Wound With Input Voltage Range 90V To 260V , Distilled Water For Batteries , Power Diodes P-Type/ N-Type ( 40 To 100 A) With Heat Shink , Charger Coil 240/36V Ac , Avr Card Compatile With Existing Chargers , Dc Volt Meter ( 0-60V) , Dimmer/Variac 110V To 260Vac , Power Transformer Equipments , Winding Temperature Meters For 3.15/4/5/6.3/10 Mva For Various Makes Lv (Make-(Emco/Yoca/Excel) , Oil Temperature Meters For 3.15/4/5/6.3/10 Mva For Various Makes (Make-(Emco/Yoca/Excel) , Power Oil Conforming To Is:335 Standards , 33 Kv Bushing For 10 Mva Power Transformer , 33 Kv Bushing For 6.3 Mva Power Transformer , 33 Kv Bushing For 5/4/3.15 Mva Power Transformer , 33 Kv Bush Rods For 10 Mva Power Transformer , 33 Kv Bush Rods For 6.3 Mva Power Transformer , 33 Kv Bush Rods For 5/4/3.15 Mva Power Transformer , 11 Kv Bushing For 10 Mva Power Transformer , 11 Kv Bushing For 6.3 Mva Power Transformer , 11 Kv Bushing For 5/4/3.15 Mva Power Transformer , 11 Kv Bush Rods For 10 Mva Power Transformer , 11 Kv Bush Rods For 6.3 Mva Power Transformer , 11 Kv Bush Rods For 5/4/3.15 Mva Power Transformer , 11Kv Outdoor Breaker Bushing , Oil Sealing For 33/11Kv Bushing Suitable For 1.0/3.15/2.5/6.3/10Mva , Miscellanous Items , Aluminum Thimble 120 Sqmm 3Mm Thick , Aluminum Thimble 185 Sqmm 3Mm Thick , Aluminum Thimble 240 Sqmm 3Mm Thick , Aluminum Thimble 300 Sqmm 3Mm Thick , Aluminum Thimble 400 Sqmm 3Mm Thick , Aluminum Thimble 630 Sqmm 4Mm Thick , Flexible Insulated Copper Bus/ Braid , Copper Bus Bars 12 Mm Thick , Aluminum Bus Bars 12 Mm Thick , T-Clamps For 0.1 Acsr 400A Presure Di-Cast , T-Clamps For 0.15 Acsr 500A Presure Di-Cast , T-Clamps For 0.20 Acsr 630A Presure Di-Cast , Isolator Pad Clamps 630A Presure Di-Cast , Single Phase Water Pump Motor, Power: 1 Hp , Led Lamp 15 Watt, B-22 Type (Make-Syska/Havells/Wipro/Surya/Ce/Gm) , 50 Watt Led Street Light With Fitting Complete (Make-Syska/Havells/Wipro/Surya/Ce/Gm) Ip-67 , Automatic Voltage Stablizer 5 Kva Copper Wound , 1.5 Sqmm Multistranded Copper Wire (Make-Polycab/Anchor/Havells/Kei/Ce) , 2.5 Sqmm Multistranded Copper Wire (Make-Polycab/Anchor/Havells/Kei/Ce) , 4 Sqmm Multistranded Copper Wire (Make-Polycab/Anchor/Havells/Kei/Ce) , 16 annual periodical maintenance Top (Make-Anchor/Havells/Crompton/Equivalent) , 16 annual periodical maintenance Switch (Make-Anchor/Havells/Crompton/Equivalent) , 16 annual periodical maintenance Socket (Make-Anchor/Havells/Crompton/Equivalent) , 16 annual periodical maintenance Combine (Socket/Switch) (Make-Anchor/Havells/Crompton/Equivalent) , 16 annual periodical maintenance Extension Board With 5 Socket With Fuse And Switch (Make-Anchor/Havells/Crompton/Equivalent) , Pvc Flexible Pipe 1/2 Dia , Ppr Pipe 0.75 Dia , Ppr Pipe 0.5 Dia , Poly Propline Rope-20-30 Mm , Motorized Wood Cutter (58Cc 3.5Hpchain Saw With 22 Inch Cutter Bar Power Full Engine) , Pt Clamps , 33Kv La Clamps 6Mm Thick , Pad Clamps (Aluminuim /Bi Metalic 600A)Presure Di-Cost , Baby Insulators With Nuts & Bolts , 33Kv Ct Clamps ( Threaded And Band Type Cu Made) Tin Coated , Crimping Tool Xple Cable ( Hydraulic Type Upto 120 Sqmm To 630 Sqmm) , Korean Mink Blanket 220X240 Cm 4Kg Weight.Rate Be Quoted Per Kg , Pvc Insulated Copper Bus Bar (50 Mm X 12 Mm) Including Nuts And Bolts 1250A , 11 Kv Vacuum Interrupters (800A/600A) Suitable For Vijai, Er, S&S, Alind, Crompton, Electric Field, Abb, Stelmac, Pascal. Indoor/Outdoor Breakers. , 11 Kv Vacuum Interrupters (800A/600A) Suitable For L&T, Schneider, Sudhir Etc. , 11 Kv Vacuum Interrupters Housing Of Below Mentioned Make. , Vijai And Easun Reyrolle (Per Phase) , Alind (Assembly Upper Set/ Lower Set). , Abb/Electric Field/Crompton/S&S ( Per Phase) , Sudhir And Schneider (Per Phase) , Outdoor Type Pcvcb Upper And Lower Part(Per Phase) , 11 Kv Vcb Equipments Below (Make-Vijai/Alind/Schneider/Crompton/Siemens/Abb/Bhel/Pascal/ Electric Field/Ece/Mei/Alstom/Easun Reyrolle/S&S) , Voltmeter 11Kv/110V , Ampere Meter , Selector Switch- 16 Amps Vss/Ass , Led Panel Indicators , Push Button With 2No+2Nc , Master Tripping Relay With 4No+4Nc , Hrc Fuse With Base -16 Amps , Connecting Ribs , Auxilary Switch With 8No+8Nc Complete With Bracket And Lever , Auxilary Switch With 12No+12Nc Complete With Bracket Lever , Auxilary Relay -30 A , Trip Circuit Supervision Relay , Bell/Buzzer , Arching Chamber , Tripping Mechanism , Re-Setting Links , Operating Shaft , Shower Contact , Isolating Sockets , Brass Chamber , Lifting Rods , Rollers , Closing Shaft , Contact Bar , Aluminum Chamber , Spring Tension Rod , Gear Assembly , Bmr Mechanism Complete , 33 Kv C&R Panel Equipments (Make Vijai/Alind/Schneider/Crompton/Siemens/Abb/Bhel/Pascal/ Electric Field/Ece/Mei/Alstom/Easun Reyrolle/S&S) , Bucholz Relay , Winding Temperature Relay , Oil Temperature Relay , Tripping Relay , Alarm Relay , Master Tripping Relay With 4No+4Nc , Tnc Switch 25 Amp. , Energy Meter Of Secure Make With Latest Series Premier 500 Of 11Kv Level And 33Kv Level With 5A Secondary. 11Kv/110V-5A / 33Kv/110V-5A , Electronic Hooter , Ampere Meter With Selector Switch , Voltmeter With Selector Switch , Hrc Fuse With Base , Bell/Buzzer , 2.5 Mm² Control Cable Copper Armoured , 1.1 Kv Grade, Isi, Frls , 12 Core . , 8 Core , 6 Core , 4 Core , 2 Core , 33 Kv Vcb Equipments (Make : Electricfield/Crompton/Abb/Bhel/Sudhir/Pascal/Beeco Lawrie/Megawin) , 33 Kv Vacuum Interrupter 1250A , 33 Kv Porcelain Post Insulator (Msli 1200+) , Operating Rods , Tripping/Closing Coils , Motor Charging 240, 1Cb, 0.1 Kv , Gasket , Operating Shaft , Mechanism Housing , Gear Assembly , Vacuum/Gas Charging Valve , Input/Output Housing Terminal Pads Din Pail Mounted Type , Xlpe Lt Cable 3.5 Core, Armoured, Fire Resistant Of Sizes , 95 Sq.Mm , 120 Sq.Mm , 185 Sq.Mm , 240 Sq.Mm , 300 Sq.Mm , 400 Sq.Mm , 2Mva/1Mva/630Kva/400Kva/250Kva/100Kva ,33/0.433 Kv, 3-Phase Distribution Transformers Eqiments: , 1600 annual periodical maintenance 4P Acb Drawal Type , Breaking Capacity 50Ka With Enclosure , Mccb ‐ 630 Amps , 36 Ka, 4P With Box Ics=100% Icu At 415 (Ka Rms) , Mccb ‐ 400 Amps , 36 Ka, 4P With Box , Mccb ‐ 250 Amps , 36 Ka, 4P With Box , Mccb ‐ 160 Amps , 36 Ka, 4P With Box , Mccb ‐ 1200 Amps , 36 Ka, 4P With Box , 120 Mm² Xlpe Lt Cable 1 Core, Armoured, Frls , 240 Mm² Xlpe Lt Cable 1 Core, Armoured, Frls , 400 Mm² Xlpe Lt Cable 1 Core, Armoured, Frls , 630 Mm² Xlpe Lt Cable 1 Core, Armoured, Frls , 33/0.433 Kv Transformer Lv Bushing Suitable For 100Kva To 2 Mva: , 33/0.433 Kv Transformer Lv Bush Rods Suitable For 100Kva To 2 Mva: , Safety Equipments , Safety Helmets Make-3M/Akamgo/ Hilson) , 33Kv Hand Gloves (3M/Crystal/Honeywell/Meeco/Jyot) , Safety Shoes Valcanised Rubber Made (Make-Allen/ Hillson/ Gasoline/Liberty/Acme/Bata/Neosafe/Honetwell) , Safety Belts Shock Absorber Type (Make-3M/Neo) , Safety Glasses (Make-Stanley/ 3M / Allen) , Safety Jackets (Make-Allen/ Hillson/ Gasoline) , Rain Protective Suit Complete- Pant And Jacket Ip-67 Protected , Fire Extingiusher Co₂ Type Of 6.5 Kg Capacity For Control Room , Fire Extingiusher Abc/Dpc Type Of 9 Kg Capacity For Control Room , Refilling Of Empty/Expred Fireextinguishers , Rubber Mat 1Mx2m 19Mm Thick
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 5
Jammu And Kashmir View Result →
3.
Public Administrative Department #11258632 AOC
Tender For Providing And Fixing Of Spares For Ht, Lt, Apfc, Starters, Other Panels And Repairing Of Various Equipment And Electrical Installation For Gangapur Dam Pumping Station, Booster Pumping And Various Tp Of Nmc.-1 P/F digital ammeter for measuring current 2 P/F digital voltmeter for measuring voltage 3 P/F multifunction meter 4 P/F selector switches for voltmeter & ammeter 5 P/F light emitting diode type indicator 6 P/F switch disconnector fuse (SDF) a 100A. b 200A. c 300A. d 400A. e 630A. f 800A. 7 P/F moulded case circuit breaker (MCCB) a Up to 100A. b 200A. c 250A. d 315/400A. e 600 / 630A. f 800A. 8 P/F MCB a 6A to 32A b 40A to 63A. c P/F One way distribution board suitable for MCB 9 P/F Busbar chamber with triple pole neutral aluminium bus bar a 100A. b 200A. c 300A. d 400A. e 630A. f 800A. 10 P/F DOL starter a Up to 7.5HP. b Up to 10HP. 11 P/F street light bracket complete 12 P/F FRP box on pole/wall complete a 150mm x 125mm x 100mm, 2.7 mm thick b 250mm x 200mm x100 mm, 2.7 mm thick c 300mm x 200mm x125 mm, 2.7 mm thick 13 P/F LED 22W tube light fitting (4 feet) with aluminium housing, heat sink, integrated HF electronic driver complete 14 Providing and filling Transformer oil 15 Point wiring in PVC trunking (casing-capping) with (2+1E) copper wire, modular type switch, earthing and required accessories 16 Point wiring for independent plug in PVC trunking (casing capping) with (2+1E )FRLSH grade copper wire, modular type switch, earthing and required accessories 17 P/F mains with 2 X 2.5sq.mm 1.1KV grade copper PVC stranded/solid wire complete (2 core, 71+36(1 core earthing)=107/- ) 18 Supplying and erecting PVC trunking (PVC casingn- capping) of size 25mm with accessories on wall/ceiling 19 P/F half round 15cm dia RCC hume pipe with necessary back filling etc complete 20 Providing and spreading stone metal 25mm size for 100mm depth above the ground level. 21 P/F three phase heavy duty power capacitors in suitable banks with voltage rating 440V, 50Hz 22 Providing and laying Aluminium conductor 3.5 core XLPE/PVC armoured 1.1KV grade cable a 25sq.mm b 35sq.mm c 50sq.mm d 70sq.mm e 95sq.mm f 120sq.mm g 150sq.mm h 185sq.mm i 240sq.mm j 300sq.mm k 400sq.mm 23 Providing and laying Aluminium conductor 1 core XLPE/PVC armoured 1.1KV grade cable a 1 Core, 630sq.mm b 1 Core, 800sq.mm c 1 Core, 1000sq.mm 24 Providing and laying Aluminium conductor 4 core XLPE/PVC armoured 1.1KV grade cable a 4sq.mm b 6sq.mm c 10sq.mm d 16sq.mm 25 Providing and laying Aluminium conductor 2 core XLPE/PVC armoured 1.1KV grade cable a 4sq.mm b 6sq.mm c 10sq.mm 26 Providing and laying copper conductor 2.5sq.mm XLPE/PVC armoured 1.1KV grade cable a 2 Core, 2.5sq.mm b 3 Core, 2.5sq.mm 27 P/L flexible PVC sheathed submersible type copper cable. a 4 core 2.5 sq mm b 4 core 4 sq mm c 4 core 6 sq mm d 4 core 10 sq mm e 4 core 16 sq mm f 4 core 25 sq mm g 4 core 35 sq mm 28 Providing and laying Alu. conductor 3 core, XLPE /PVC 3.3KV armoured cable a 70sq.mm b 95sq.mm c 120sq.mm d 150sq.mm e 185sq.mm f 240sq.mm g 300sq.mm h 400sq.mm 29 P/F heat shrinkable outdoor termination kit for 3.3Kv (E) XLPE HT cable erected and connected to the supply with insulated sleeves,additional lugs & nut bolts for all core for 3 core cable with HT testing at site etc complete a 70-120sq.mm b 150-185sq.mm c 240-400sq.mm 30 P/F Heat shrinkable indoor termination kit for 3.3Kv (E) XLPE HT cable erected and connected to the supply with insulated sleeves,additional lugs & nut bolts for all core for 3 core cable with HT testing at site etc complete a 70-120sq.mm b 150-185sq.mm c 240-400sq.mm 31 P/F Heat shrinkable straight through joint kit for 3 core, 3.3Kv (E) XLPE HT cable etc complete a 70-120sq.mm b 150-185sq.mm c 240-400sq.mm 32 Providing and laying Aluminium conductor 3 core, XLPE/PVC 11KV armoured cable a 95sq.mm b 120sq.mm c 150sq.mm d 185sq.mm e 240sq.mm f 300sq.mm 33 P/F heat shrinkable outdoor termination kit for 11Kv (E) XLPE HT cable erected and connected to the supply with insulated sleeves,additional lugs & nut bolts for all core for 3 core cable with HT testing at site etc complete a 70-95sq.mm b 120-185sq.mm c 240-300sq.mm d 400sq.mm 34 P/F Heat shrinkable indoor termination kit for 11Kv (E) XLPE HT cable erected and connected to the supply with insulated sleeves,additional lugs & nut bolts for all core for 3 core cable with HT testing at site etc complete a 70-95sq.mm b 120-185sq.mm c 240-300sq.mm d 400sq.mm 35 P/F Heat shrinkable straight through joint kit for 3 core, 11Kv (E) XLPE HT cable etc complete a 70-95sq.mm b 120-185sq.mm c 240-400sq.mm 36 Providing and laying Alu. conductor 3 core, XLPE / PVC 33KV armoured cable a 95sq.mm b 120sq.mm c 150sq.mm d 185sq.mm e 240sq.mm f 300sq.mm 37 P/F heat shrinkable outdoor termination kit for 33Kv (E) XLPE HT cable erected and connected to the supply with insulated sleeves,additional lugs & nut bolts for all core for 3 core cable with HT testing at site etc complete a up to 70sq.mm b 95-150sq.mm c 185-240sq.mm d 300-400sq.mm 38 P/F Heat shrinkable indoor termination kit for 33Kv (E) XLPE HT cable erected and connected to the supply with insulated sleeves,additional lugs & nut bolts for all core for 3 core cable with HT testing at site etc complete a up to 70sq.mm b 95-150sq.mm c 185-240sq.mm d 300-400sq.mm 39 P/F Heat shrinkable straight through joint kit for 3 core, 33Kv (E) XLPE HT cable etc complete a up to 70sq.mm b 95-150sq.mm c 185-240sq.mm d 300-400sq.mm 40 P/F Heat shrinkable straight through joint kit for flexible PVC sheathed submersible type copper cable. a 4 core 2.5 sq mm b 4 core 4 sq mm c 4 core 6 sq mm d 4 core 10 sq mm e 4 core 16 sq mm f 4 core 25 sq mm g 4 core 35 sq mm 41 P/F HT capacitor suitable for 3.3KV in suitable banking 42 Making fabrication work using 16 gauge metal sheet with bending, cutting, drilling and welding complete 43 Powder coating in siemens gray colour 44 Making Iron work for fabrication with bending, cutting, drilling and welding complete 45 Epoxy painting on both side of approved colour shade of provided iron work 46 P/F GI strip of suitable size 47 P/F M.S. stand for fire bucket 48 P/F Wall hook for fire bucket 49 P/F G.I fire bucket 9Lit 50 P/F Instruction chart 51 Pair of rubber hand gloves 52 Supplying and erecting fire extenguisher 4.5Kg 53 P/F High voltage insulating Electromat confirming to IS 15652 :2006 a Suitable for 3.3KV. b Suitable for 11KV. c Suitable for 33KV. 54 Providing and laying double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete a 50 mm b 75 mm c 90 mm d 120 mm e 160 mm f 175 mm g 200 mm 55 P/F Flood light LED fitting for street light a 50W b 70W c 100W d 120W e 155W f 195W 56 P/F aluminium PVC unarmoured cable 2 X 6sq.mm of 1.1kv grade 57 P/F mini feeder pillar triple pole with 200A MCCB as incomer etc complete 58 P/F mini feeder pillar triple pole with 300A MCCB as incomer etc complete 59 P/F fencing of section having size 2450 mm in height from ground level and 1200 mm width with angle iron frame work complete 60 P/F double leaf hinged door each 1500 mm in width x 1850 mm in height using B class, GI pipe with angle iron supports, chain link wire meshcomplete 61 P/F 50 x 50 x 6mm angle iron corner support 0.5m away from fence support fixed etc. 62 Providing and fixing ultra violet storage type water purifier (RO+UV+UF) with softener for safe drinking water consisting of UV germicidal tube of 8W capacity choke made of copper wire and two indicator lamps 63 P/F analog Ammeter for measuring current 64 P/F analog Voltmeter for measuring voltage 65 Providing and laying XLPE armroured cable for 3.3KV with ISI mark 1 core 630 sq.mm. stranded aluminium wire in an approved manner. 66 P/F heat shrinkable outdoor termination kit for 3.3Kv (E) XLPE HT cable erected and connected the supply with insulated sleeves,additional lugs nut bolts for 1 x 630 sqmm cable with HT testing site etc complete 67 P/F programmable logic controller for Thyristor logic KPOPF – 406 – T. 68 P/F Injector module for Thyristor logic KPIPF 406 – T. 69 P/F Zero switching module for Thyristor logic KPZPF – 406 – T. 70 P/F current generator 440V, 50Hz, for final compensation of real time PFC after basic compensastion using programmable logic controller, relay module, ZCS control thyristor units with its software, hardware, power and control cabling etc complete. a Up to 42A b 42A to 56A c 70A to 105A. d 112A to 140A 71 P/F ROM-51 memory controller with accessories along with routine software program for Thyristor logic. 72 P/F ROM-51 memory controller with accessories along with routine software program for zero switching logic. 73 P/F voltage transformer with 11V, 18-0-18V, 22V, 8V secondary. 74 P/F output module for soft starter-KPOSS-306. 75 P/F proportional Integral card with operational amplifier KPISS-306. 76 P/F analog to Digital converter ATD-09. 77 P/F MCR-31 Main controller with accessories. 78 P/F 7-Segment common anode display controller DSP-79 with accessories. 79 P/F RAM-64 memory unit with accessories. 80 P/F ROM-SS-64 memory unit with accessories along with routine software program. 81 P/F ROM-SS-51 memory unit with accessories along with routine software program 82 P/F flat band cable set 26pin. 83 P/F flat band cable set 20pin. 84 P/F glass type relay O/E/N RL-24. 85 P/F 2A fuse box of EI for power supply (20Nos). 86 P/F 2A glass fuse base open type FBO. 87 P/F tertiary current transformer 88 P/F PLA relay 24D 1NO RDRL-24. 89 P/F SMPS ripple filter choke 5V DC, 1500mA. 90 P/F 24VDC, 10A Electromechanical relay PLA and snubber. 91 P/F voltage transformer with O/P 6.8V, 11.5V, 22.5V Delta to star. 92 P/F programmable logic controller module for contactor logic KPOPF – 406 – C. 93 P/F injector module for contactor logic KPIPF – 406 – C. 94 P/F relay module for contactor logic KPRLPF – 406 – C. 95 P/F ROM-51 memory controller with accessories along with routine software program for contactor logic. 96 P/F thyristor back to back connected suitable for following starters and Capacitor banks. a 75HP. b 120HP. c 215HP. d 300HP. e 10KVAR f 15KVAR g 20KVAR h 25KVAR i 30KVAR 97 P/F inductor suitable for following Capacitor banks. a 10KVAR b 15KVAR c 20KVAR d 25KVAR e 50KVAR 98 P/F electrical contactors. a 32A. b 40A. c 70A. d 110A. e 200A. f 300A. g 400A. h 650A 99 P/F main contact kit for power contactor. a 32A. b 40A. c 70A. d 110A. e 200A. f 300A. g 400A. h 650A 100 P/F HRC fuses. a 40A. b 50A. c 63A. d 100A. e 125A. f 160A. g 200A. h 250A. i 315A. j 400A. k 630A. l 800A. 101 P/F fuse bridges. a Up to 32A. b 63A. c 160A. d 250A. e 800A. 102 P/F change over switches. a 63A. b 125A. c 200A. d 250A. e 315A. f 400A. g 630A. h 800A. i 1000A. 103 P/F timers. a ET-100. b Star-Delta. 104 P/F FASD starter. a ML2 b ML3 c ML4 105 P/F energy efficient street light fitting using 36W CFL lamps complete. 106 P/F 11KV HT fusegear for fuse switch unit of CGLucy 107 Actuator control unit. a P/F forward / reverse contactor b P/F over load relay. c P/F contact kit 108 Providing and laying copper conductor 12 core 2.5sq.mm XLPE/PVC armoured 1.1KV grade cable 109 P/F electronic control unit suitable for up to 175HP, control Supply 240V AC, Power Suply 415V AC, with all test and trials complete. 110 P/F electronic control unit suitable for up to 300HP, control Supply 240V AC, Power Suply 415V AC, with all test and trials complete. 111 P/F limit Switch for gate 112 P/F 10 Turns Preset. 113 P/F panel accessories such as push button with indicators, NO/NC contact, emergency stop push button, copper lug for control cable, gasket, etc complete. 114 P/F C I pipe type earthing etc complete. 115 P/F 230V, 2 C/O panel mounted relay. 116 P/F single phasing preventer relay 117 P/F single phase, under voltage, over voltage protection relay. 118 P/F oil temperature sensing relay 119 P/F winding protection relay 120 P/F reverse rotation sensing relay 121 P/F Motor protection relay for LT motor 122 P/F Control transformer with protection circuit 123 P/F PVC type earthing chambers with accessories for earthing. 124 Power contactor coil LC-1F 330 125 P/F sequence controller 126 Providing, fixing termination box for submersible pump to ATS starter with bus bar, terminations etc complete 127 Providing and laying 95sq.mm copper conductor 1 core flexible PVC unarmoured 1.1KV grade cable 128 Energy meter panel a P/F Energy meter single phase 230V, 50Hz, 10A supply complete b P/F Energy meter 3 Phase, 4 wire, 50Hz, 100A supply complete c P/F L.T. Current transformer of suitable ratio d Making fabrication work using 16 gauge metal sheet with bending, cutting, drilling and welding complete e Powder coating in siemens gray colour f Control wiring using copper wire, ferrule, lugs, tie saddle, spiral etc complete. g Panel accessories such as hardware, gasket, insulator, panel knob, panel lock for each feeder complete . h Dismantling of old meter panel by disconnecting connections of all cables, etc complete i Installation of new meter panel by fixing meter box, making incoming and out going connection etc complete. 129 Starter Panel a P/F digital ammeter for measuring current b P/F digital voltmeter for measuring voltage c P/F selector switches for voltmeter & ammeter d P/F light emitting diode type indicator e P/F L.T. Current transformer of suitable ratio f Providing and fixing Main Incommer 63A moulded case circuit breaker g P/F 100A Busbar chamber with triple pole neutral aluminium bus bar h Making fabrication work using 16 gauge metal sheet with bending, cutting, drilling and welding complete i Making Iron work for fabrication with bending, cutting, drilling and welding complete j Powder coating in siemens gray colour k P/F DOL ML 1.5 starter l P/F FASD ML2 starter m P/F FASD ML3 starter n P/F FASD ML4 starter o P/F Over load relay. p Control wiring using copper wire, ferrule, lugs, tie saddle, spiral, etc complete. q Local/remote wiring using copper wire, ferrule, lugs, tie saddle, spiral, etc complete. r Panel accessories such as hardware, gasket, insulator, panel knob, panel lock, bus bar terminals, etc complete. s Dismantling of old starter panel by disconnecting connections of all cables, etc completet Installation of new starter panel by fixing starter panel, making incoming and out going connection etc complete. u Terminations main outgoing cables by using lugs glands etc complete. 130 LT Panel, Changeover Panel, Distrubution Panel, Feeder Panel a Power wiring up to 63A feeder using copper wire, lugs, tie saddle, spiral etc complete. b Control wiring for metering using copper wire, ferrule, lugs, tie saddle, spiral etc complete. c Panel accessories such as hardware, gasket, insulator, backlite, panel knob, panel lock, push button with indicators, heavy duty connectors earthing arrangement, etc complete for following feeders i Up to 100A ii 100A to 250A iii 250A to 400A iv 400A to 800A d Dismantling, disconnecting connections of all cables, shifting old panel in godown etc complete of following capacity. i Up to 100A ii 100A to 250A iii 250A to 400A iv 400A to 800A e Installation of panel at desired place including loading unloading and transportation of following capacity i Up to 100A ii 100A to 250A iii 250A to 400A iv 400A to 800A f Making new terminations of main incoming/outgoing cables, etc complete for following feeders. i Up to 100A ii 100A to 250A iii 250A to 400A iv 400A to 800A g Interlocking, forward/reverse, timing and control circuit/star delta circuit etc control wiring using copper wire, ferrule, lugs, tie saddle, spiral, etc complete for one feeder. 131 P/F 3 phase street light timer controller of 60 A per phase rating with in-built relay, timer, protections, display 132 Providing, fixing and testing of HT TOD meter of appropriate class with required accessories along with co ordnation with MSEDCL complete. 133 Providing, fixing and testing of LT TOD meter of appropriate class with required accessories along with co ordnation with MSEDCL complete. 134 P/F Motor protection circuit breaker 135 P/F 3 Phase heavy duty industrial socket. 136 P/F 1 Phase heavy duty industrial socket. 137 P/F and erecting 6mm Polycarbonate multiwall ultravoilet protected sheet for roofing over fabricated steel structure as per detail design, including fixing the Polycarbonate sheet with alluminium angle & Flat anodized & dyed as per approved shade including all water proofing materials, nuts bolts hardware, labour & square pipe, angles, fabrication complete including all hardware etc. as required . (only actual area of polycarborted sheet to be considered for measurements) 138 Making isolation circuit using AB switch / D.O. Set for single pole & converting the cutpoint by dismantling with nessasary material, jumping, earthing along with arrangement of shutdown etc. complete. 139 P/F diesel filling pump for filling diesel in dg sets from store tanks etc complete. 140 P/F meter box for single phase energy meter complete. 141 P/F meter box for three phase energy meter with compartment for mccb/mcb etc complete. 142 P/F of spares for DG control panel a Flush mounted panel meter three phase four wire for frequency etc. b 12V/80AH Battery c 12V/100AH Battery d 12V/150AH Battery e 12 V/180AH Battery f 12V/200AH Battery g Battery water h EPU unit i AVR j AMF Controller k Voltmeter DC l Ammeter DC m Push button n ESR D1 o 12V battery charger p 24V battery charger q Overload relay r Relay s Electronic Timer t Hooter u Connector 143 Reconditioning of transformer a Inspection of distribution transformer on HV and LV side b Dismantling the distribution Transformer from the plinth / foundation c Providing and filling Transformer oil d Painting of transformer using smoke gray paint complete e Providing and rewinding of copper material for HT coils f Heating of core and winding, including removing of moisture etc complete g Providing oil arresting sheet for low tension side of R Y B studs, 5mm thick properly fitted in the studs of transformer. h Providing oil arresting sheet for top cover of oil chamber, LT connection box, oil tank etc parts ,5mm thick properly fitted in the top cover and nut bolts of transformer i Providing R Y B stud bushings over the oil arresting sheet on the studs of transformer . j Reinsulation by high quality uniform covering throughout of 11KV windings using accessories complete k Reinsulation by high quality uniform covering throughout of 415V windings using accessories complete l Repairing and servicing of tap changer of transformer m Transformer oil filtration n Changing silica jel of breather and adding breather oil. o Loading, unloading and transportation of transformer. p Attendance, engineering charges for connection of HT/LT cables and giving satisfactory test & trials of transformer complete 144 P/F Analog input module AI 2xI, 4-wire transmitter (+/-20 mA /13 bits+sign, 4 mA to 20 mA/13 bits), standard 145 P/F Analog input module AI 4xI, 2wire- MU(4..20mA), standard 146 P/F Digital output module DO 8xDC24V/0.5A, supports isochrone mode 147 P/F Power module PM-E for electronic modules, 24 VDC, with diagnostics 148 P/F Digital input module DI 8xDC24V, supports isochrone mode 149 P/F IM151-8PN/DP central processing unit work memory 192KB; 0.06ms/1000 instructions; PROFINET connection; S7 communication (loadable FBs/FCs); PROFINET IO-Controller; supports RT/IRT; PROFINET interface and 3 ports; MRP; PROFINET CBA; PROFINET CBA-Proxy; transport protocol TCP/IP, 150 P/F Communication module with a serial interface (RS232, RS422 or RS485) and Modbus master log with 8 byte I/O interface 151 P/F Communication module with a serial interface (RS232, RS422 or RS485) and Modbus slave log with 8 byte I/O interface 152 P/F Programmable logic controller 1769 TW Digital input module 32 point. 153 P/F Programmable logic controller 1769 Analog input module 8C 0-10V 0-20 154 P/F Programmable logic controller 1769 Digital output module 32 point. 155 P/F Programmable logic controller 1769 Power unit. 156 P/F Programmable logic controller 1769 Compact I/O to DSl module. 157 P/F Programmable logic controller 1769CMPAC Logix processor ethernet 2MB 158 P/F Programmable logic controller 1969 Endcap right. 159 P/F Laser printer Spares for VCB 160 P/F closing coil assembly- 4VC49-110 161 P/F tripping coil assembly- 4VC49-106 162 P/F micro switch 163 P/F breaker auxiliary switch 164 P/F spring charging motor 165 P/F closing shaft with spring. 166 P/F tripping shaft with spring. 167 P/F charging handle assembly 168 P/F pinion gear assembly 169 P/F spur gear assembly 170 P/F bridge rectifier 171 P/F spring for tripping catch 172 P/F tripping catch assembly 173 P/F closing catch assembly 174 P/F driving rod assembly 175 P/F nut assembly 176 P/F cam shaft assembly 177 P/F vacuum interrupter Spares for VC 178 P/F closing coil assembly for VC 179 P/F tripping coil assembly for VC 180 P/F 2 Pole auxiliary switch 181 P/F micro switch 182 P/F bridge rectifier 183 P/F vacuum interrupter 184 P/F contact shroud assembly 185 P/F PDS assembly- 4VC19-0027/01 186 P/F shutter assembly- 3VB79-310/04 187 P/F 5 pole auxiliary switch- J309-022 HT Panel Spares 188 P/F moulded contact shrouds- 1VB79-0009/04 189 P/F shutter assembly- 3VB79-0087/02 190 P/F push button- green button with spring. 191 P/F push button- red button with spring. 192 P/F PDS assembly- with fixing nut bolt- 4VC19- 0027/03 193 P/F insulated stud assembly 194 P/F flexible jumper with fixing bolt- 3VC19-0009 195 P/F coupling 196 P/F bus conductor- upper- 4VC13-0002 197 P/F bus conductor- lower 198 P/F top cover for U barrier- 4VC19-0117/01 199 P/F 16 Pin plug with socket- 4VC46-0303 200 P/F PT fuse 201 P/F voltage transformer (PT) of suitable Ratio secondary 110VAC and suitable class: 202 P/F current transformer (CT) of suitable ratio secodary 5A and suitable class. 203 P/F TNC switch 204 P/F local remote switch 205 P/F PVC shroud- CT/PT/CR surg 206 P/F PVC shroud- 630A 207 P/F contact shroud for PT. 208 P/F rubber gasket for door 209 P/F bushing plate- VCB 210 P/F control fuse with assembly, 440V 211 P/F loose vacuum contactor [Electrically held] type JVE1-604. 212 P/F loose vacuum Contactor for soft starter MVC400D, 400Amp, 3.3KV, 2P, Control supply 220VDC, Solenoid type, with 3 economy resistance- CVC0004, 213 P/F electronic timer suitable in HT starter. 214 P/F Over current, Earth fault relay and short circuit protection relay and retrofitting if required. 215 P/F Under voltage/ Over voltage protection relay and retrofitting if required. 216 P/F Master trip relay and retrofitting if required. 217 P/F Trip circuit supervision relay and retrofitting required. 218 P/F auxillary relay for contact multification RE-300 Aux supply: 110V AC / DC 219 P/F auxiliary contactor for vaccum contactor operation 110VDC with resistor complete. 220 P/F limit switch for service & test position 2 Pole. 221 P/F tripping relay VAJH 3NO + 1NC, 110VDC 222 P/F selector switch for HT panel 223 P/F breaker operated switch 10 pole, 5NO + 5NC. 224 P/F power pack unit Input: 110V AC, Output: 110VDC 225 P/F On line UPS pure sine wave with standard features a 1KVA b 2KVA c 3KVA d 6KVA e 10KVA 226 P/F SMF battery a 12 V/17Ah -18Ah b 12 V/26Ah c 12 V/42Ah d 12 V/65Ah e 12 V/100Ah 227 P/F fixed resistor 1000 ohms. 228 P/F safety switch for VC HRC fuse P/F blow pole 1C/O 229 P/F connecting rods for safety switch 230 P/F safety switch for VC trunk Interlock 2 Pole NO + 1NC.231 P/F high voltage 3.6KV HBC fuse links for short circuit protection. 232 P/F and giving satisfactory test and trials of 3.3 KV 104Kvar Capacitor panel as per rate analysis. 233 P/F and giving satisfactory test and trials of 3.3 KV 208Kvar Capacitor panel as per rate analysis. 234 P/F MM30 type protection relay Machining and fabrication works for couplling of actuator and valve 235 P/F Universal joint 236 P/F Mounting bracket 237 P/F Flange 238 P/F Coupler 239 P/F Shaft coupler 240 P/F Additional shaft 241 P/F Fastener bolt, hardware, etc accessories 242 P/F 0.6mm GI sheet 243 P/F regular/ standard model Ceiling fan complete 244 P/F ISI mark modular type (two module) electronic step regulator for fan 245 P/F condenser 2.5 micro farad for ceiling fan 246 P/F anchor type fastener fan hook, with 2 nos. of 10 mm dia x 75 mm long with necessary materials for ceiling fan. 247 P/F fan clamp of 30 x 5 mm. M.S. flat of required length and 10 mm. M.S. bolt and nuts erected with necessary hook of 10 mm. M.S. round bar and painted. 248 P/F fan hook of 10 mm. M.S. round bar grouted in RCC slab 249 P/F ‘B’ grade G.I. pipe / M.S. pipe down rod duly painted for fan complete erected with PVC three core flexible cable 1 sq. mm copper PVC wire 250 P/F heavy duty exhaust Fan 251 Refilling of fire extinguisher of by dismantling from site to workshop for refilling which includes removing of existing powder and cleaning the cylinder, delivery pipe , nozzle internally and refilling new powder complete with reinstalling properly at site 252 Dismantalling old rusted perforated type cable tray.253 P/F hot dipped galvanized perforated type cable tray manufactured from 16 swg (1.6 mm thick) GI sheet of 100 mm width with necessary coupler plates and hardware in approved manner etc complete. 254 P/F, testing and commissioning split type variable speed Inverter technology room Air conditioning unit 1.5 TR capacity suitable to operate on 250V, 50 cycles, A.C.supply having 1 no of air handling unit hiwall / floor mounting type complete. 255 P/F, testing and commissioning split type variable speed inverter technology room Air conditioning unit 2 TR capacity suitable to operate on 250V, 50 cycles, A.C. supply having 1 no. of air handling unit hi-wall/ floor mounting type complete 256 P/Laying PVC insulated PVC round sheathed 2.5 sq.mm 3 core flexible multi stranded copper Industrial cable for voltage grade up to 1.1 kV 257 P/F copper pipe suitable for refrigeration system having size 12.7 mm complete. 258 P/F bracket for split type AC 259 P/F copper pipe suitable for refrigeration system having size 15.9 mm complete. 260 P/F Elastomeric Nitrile rubber / foam tube type sleeves for over coating and insulating on provided copper pipes having sizes 12 mm 261 P/F Elastomeric Nitrile rubber / foam tube type sleeves for over coating and insulating on provided copper pipes having sizes 16 mm 262 P/F rigid PVC pipe 20 mm dia.with PVC accessories for drain 263 Carrying out core cutting of size 3 to 5 dia x 15 length in the C.C./rock/stone wall with the help of specialized core cutting machine in proper manner and finishing the site as original. 264 Providing, Installation, Testing and commissioning of borewell type maintenance free chemical earthing comprising of Electrode of 80 mm diameter rod of Length 3m along with 25 kg Carbon based environment friendly back fill ground enhancing compound required to fill up the excavated earth with required quantity complete. 265 Providing, Installation, Testing and commissioning of borewell type maintenance free chemical earthing comprising of Electrode of 80 mm diameter rod of Length 1.5m along with 15 kg Carbon based environment friendly back fill ground enhancing compound required to fill up the excavated earth with required quantity complete. 266 Providing and making platform by making excavation for foundation, situ cement concrete of M-10, uncoursed rubble masonry of trap, rubble stone soling 15cm to 20dc thick including hand packing and compacting, situ cement concrete of M20 grade trap, steel bar rainforcement of various diameters for RCC work, sand faced plaster externally in cement mortar, etc complete 267 Providing hand drill Machine 268 Providing hand grinder 269 Providing Crimping tool up to 400sq.mm 270 Providing Insulator tester ( Megger ) cranking type having metal body of range 100 Volts 1000 Ohms 271 Providing fix spanner set 12 piece set 6 -32 mm 272 Providing Bi-hexagon Ring spanner 12 piece set 6 - 32 mm 273 Providing screw driver a Screw driver Engineering pattern 6 X 300 mm b Screw driver Engineering pattern 8 X 200 mm c Screw driver Engineering pattern 5 X 200 mm d Screw driver Engineering pattern 5 X 300 mm e Screw driver with green neon bulb line tester 3.6 X 60 mm 274 Providing Multimeter 275 Providing Tong Tester ( Clip on meter ) of range 0- 10-30-100-1000 Amps and 0-300-600 Volts 276 Providing Ball pen hammer with handle 800 gm 277 Providing Hack saw frame 300 mm size with heavy duty blade 278 Providing blower 279 Providing single phase welding machine 280 P/F fixing isolator suitable for 33KV capacity 281 Providing office regular with handle chair 282 Providing fabricated powder coated rack 283 Providing computer table 284 Providing 18 compartment steel clothes locker with powder coating, locking arrangement, etc complete. 285 Providing regular office wooden table 286 Providing wooden chair 287 Providing and fixing Openable Steel Storage of 750 x 450 x 2100Ht, with 4 adjustable shelves, Complete body & shutter made in 0.8mm thick & Top in 2mm thick CRCA, Shutter to be mounted with the help of cuphinges, and adjustable levelers, enitre storage in powder coated finish with 60 to 80 microns 288 Providing and fixing Openable Steel Storage of 750 x 450 x 1200Ht, with 2 adjustable shelves, Complete body & shutter made in 0.8 mm thick & Top in 2 mm thick CRCA, 2 Shutter to be mounted with the help of cup hinges, and 4 adjustable levelers, enitre storage in powder coated finish 289 Providing & Arrangemnt of High Back chair, Synchronized Mechanism with Multiple Locking, Armrest, Gaslift for Seat height adjustment, Standard 5-prong P/Nylon Base with Leatherite Upholstery 290 P/F disc type insulator suitable for 33 KV line complete erected with suitable Hardware on provided cross arms as per IS. 291 P/F pin type insulator suitable for 33 KV line, complete erected with suitable hardware on provided cross arms. 292 P/F G.I. stay set for poles, including loop insulators at inaccessible height complete with anchor plate 300 x 300 x 6 mm., straining screws, G.I. stay wire 7/8 SWG, G.I. stay rod 20 mm x 1.8 meter length and pole clamps duly erected in provided cement concrete foundation. 293 Providing and fixing Nut bolts and Sundries etc accessories 294 Making isolation circuit for all 3 phases and interlocking the same to provide 33KV output from 2 Nos of 33KV input feeders using accessories etc complete. 295 Dismantling the existing old 33KV circuits and all jumps, accessories, etc complete. 296 Providing and fixing safe shade ESE type lighting arrestor system complete with following details. a P/F safe shade ESE type lighting arrestor as per NFC17-102 (2011) UNE 211862011 standards, CPRI tested, area covered 107 Mtr, etc complete. b P/F GI mast 5mtr long wth base plate complete c P/F 6 Digit counter, etc complete d P/F accessories for lightning arrestor, etc complete. e P/F test link box etc complete. f Providing, laying and terminating single core 35sq.mm copper flexible cable for earthing 297 Providing and making overhead cablling works for clarifier bridge slipring a P/F slipring b Providing and laying copper conductor 1.5sq.mm X 4 core XLPE/PVC 1.1KV grade cable c P/F hardware, bobbin, anchor fastners, cork sheet etc accessories for slipring fixing works. d P/F GI wire of high purity of different sizes used for earthing. e P/F attachment to slipring for entering cable from top using GI pipes, coupling, flange, bend, by machining and threading the components so that cable will remain fix when clarifier is rotating. f Making arrangement using provided GI wire, bobbins to carry the provided cable overhead from filter to clarifier. g Making terminations for slipring main panel, clarifier panel, etc.Part B- Annual maintenance contract 1 Servicing and overhauling of APFC panels. A Servicing of APFC panel by making terminations of power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, tightening all connections, changing hardware, insulator, gasket, replacing provided blown fuses, fuse base, indicators and other parts as required in engineering manner for each bank complete as follows. a Control feeder for 1 to 5KVAR bank. b Control feeder for 5 to 10KVAR bank. c Control feeder for 10 to 20KVAR bank. d Control feeder for 20 to 30KVAR bank. e Control feeder for 30 to 50KVAR bank. B Servicing of main programmable logic controller injector module, ZCS module, by correcting dry solder, calibrations of three phase voltage, currents, all parameters, power supplies, tightening all connections, adjusting preset values to maintain unity power factor, checking transformer voltages, current ratios, checking of panel & cleaning of panel complete. 2 Servicing and overhauling of soft starters. Servicing of contactor by changing provided contact kits, coil, terminations, control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, voltmeter, ammeter, selector switches, servicing of analog card, digital card, display card, correcting dry solder, calibrations of three phase voltage, currents, all parameters, power supplies, adjusting preset values, checking transformer voltages, current ratios, termination of incoming outgoing cables as required. Also tightening of connections, cleaning of panel complete. a 70 to 90HP. b 90 to 120HP. c 120 to 150HP. d 150 to 215HP. e 215 to 300HP. f 300 to 1000HP 3 Servicing and overhauling of starters. Servicing of contactor by changing provided contact kits, coil, terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, push buttons, voltmeter, ammeter, selector switches checking oil level and top up, auto transformer links, termination of incoming outgoing cables as required. Also tightening of connections, setting of timers and cleaning of panel complete. a 3 to 7.5HP. b 7.5 to 12.5HP. c 12.5 to 20HP. d 20 to 30HP. e 30 to 50HP. f 50 to 70HP. g 70 to 90HP. h 90 to 120HP. i 120 to 150HP. j 150 to 215HP. k 215 to 300HP. 4 Servicing and overhauling of distribution panels. Servicing ,repairing of distribution panels by checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, provided indicators, voltmeter, ammeter, selector switches termination of incoming outgoing cables as required. Cleaning of panel, tightening of all connections of feeders of following capacity. a Up to 32A b 32A to 63A c 63A to 100A d 100A to 150A e 150A to 200A f 200A to 250A g 250A to 400A h 400A to 630A i 630A to 800A j 800A to 1000A k 1000A to 1250A l 1250A to 1600A 5 OCB to MCCB conversion. Dismantling output starter’s cable terminated to OCB, dismantling incoming and outgoing bus bar of OCB to main LT panel, dismantling OCB from main LT panel properly. Making iron frame for fitting of MCCB. Fitting of MCCB in main LT panel with proper hardware, covering the front open portion with 16SWG MS sheet with adjusting slot for MCCB handle. Terminating the R Y B connection of MCCB with main LT panel’s bus bar using appropriate rating of copper flexible cable and proper copper lugs. Reconnect the output’s starter cable to MCCB, taping all power connections, checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, voltmeter, ammeter, selector switches. Replacing indicators and other parts as required. Cleaning of panel, tightening of all connections. 6 Servicing and overhauling of actuator electrical control module. Servicing of actuator electrical control module by servicing of contactor by changing provided contact kits, coil, checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, voltmeter, ammeter, selector switches termination of incoming outgoing cables as required. Replacing blown fuses, fuse base, indicators and other parts as required. Cleaning of panel, tightening of all connections. 7 Callibrating all presets/sensor for gate/screen with open/close and electronic indication system. Checking control wiring for remote and local operation, adjusting limit switches with proper close and open, giving satisfactory test and trials of remote and local system etc complete. 8 Servicing and overhauling of alum mixer control module. Servicing of alum mixer module by servicing of SFU, servicing contactor by changing provided contact kits, coil, checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, voltmeter, ammeter, selector switches termination of incoming outgoing cables as required. Replacing blown fuses, fuse base, indicators and other parts as required. Cleaning of panel, tightening of all connections. 9 Servicing and overhauling of chlorine plant control module. Servicing of chlorine plant module by servicing of SFU, servicing contactor by changing provided contact kits, coil, checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, voltmeter, ammeter, selector switches termination of incoming outgoing cables as required. Replacing blown fuses, fuse base, indicators and other parts as required. Cleaning of panel, tightening of all connections. 10 Servicing and overhauling of clarifier control module. Servicing of clarifier module by servicing of breaker, servicing contactor by changing provided contact kits, coil, checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, voltmeter, ammeter, selector switches termination of incoming outgoing cables as required. Replacing blown fuses, fuse base, indicators and other parts as required. Cleaning of panel, tightening of all connections. 11 Servicing and overhauling of HT substation. a Servicing and overhauling of 4 pole structure, servicing air break switch by polishing contacts, applying jelly to contacts, alignment of AB switch, servicing and overhauling of D.O. set by polishing hansa and punja, applying jelly to all hansa and punja, changing fuse link tightening of connections, changing hardware, changing ACSR jumper links by properly lugging and binding using alkathene pipe. HT taping of connections, checking of insulators, insulation test of total installation and earth test of earthing pits. b Cleaning of substation area, painting of 4 pole structure , fencing and gate using aluminium paint and scraping old paint. Painting of transformers using AD gray paint and scraping old paint. 12 Servicing and overhauling of 33KV H.T. Substation at Gangapur Dam pumping station. a Servicing of air break switch by polishing contacts, applying jelly to contacts, alignment of AB switch, tightening connections, changing hardware, etc complete. b Painting of gantry structure for air break switch by cleaning all poles channels using aluminium paint 3 coats. c Servicing of D.O. set by polishing hansa and punja, applying jelly to hansa and punja, tightening connection, changing hardware and fuse wire, etc complete. d Painting of gantry structure for D.O set by cleaning all poles channels using aluminium paint 3 coats. e Servicing of PT by checking, lugging, tightening HT and earthing connections, checking, tightening secondary connections, measuring voltages at out put for main bus, bus-1 and bus-2. f Painting of gantry structure for main bus PT by cleaning all poles channels using aluminium paint 3 coats. g Painting of gantry structure for PT bus-1 and bus-2 by cleaning all poles channels using aluminium paint 3 coats. h Painting of PT for main bus, bus-1, bus-2 and MSEDCL by cleaning them and using smoke gray paint 3 coats. i Servicing of VCB by checking operating mechanism, alignment, applying jelly to various parts, control wiring, remote local operation, spring charging, insulation tests for main bus, bus-1 and bus-2. j Repairing servicing of control feeder panel for VCB/VC by checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, termination of incoming outgoing cables as required. Cleaning of panel, tightening of all connections etc complete. k Servicing of CT by checking, lugging, tightening HT and earthing connections, checking, tightening secondary connections, measuring currents at out put for main bus, bus-1, bus-2. l Painting of gantry structure for VCB and CT for main bus, bus-1 and bus2 by cleaning all poles channels using aluminium paint 3 coats. m Painting of VCB for main bus, bus-1 and bus-2 by cleaning them and using smoke gray paint 3 coats. n Painting of CT for main bus, bus-1, bus-2 and MSEDCL by cleaning them and using smoke gray paint 3 coats. o Painting of gantry structure for MSEDCL CTPT structure by cleaning all poles channels using aluminium paint 3 coats. p Painting of gantry structure for cut point by cleaning all poles channels using aluminium paint 3 coats. 16 Repairing of analog input module AI 2xI, 4-wire transmitter (+/-20 mA /13 bits+sign, 4 mA to mA/13 bits), standard 17 Repairing of analog input module AI 4xI, 2wire- MU(4..20mA), standard 18 Repairing of digital output module DO 8xDC24V/0.5A, supports isochrone mode 19 Repairing of power module PM-E for electronic modules, 24 VDC, with diagnostics 20 Repairing of digital input module DI 8xDC24V, supports isochrone mode 21 Repairing of IM151-8PN/DP central processing unit work memory 192KB; 0.06ms/1000 instructions; PROFINET connection; S7 communication (loadable FBs/FCs); PROFINET IO-Controller; supports RT/IRT; PROFINET interface and 3 ports; MRP; PROFINET CBA; PROFINET CBA-Proxy; transport protocol TCP/IP, 22 Repairing of Communication module with a serial interface (RS232, RS422 or RS485) and Modbus master log with 8 byte I/O interface 23 Repairing of Communication module with a serial interface (RS232, RS422 or RS485) and Modbus slave log with 8 byte I/O interface 24 Repairing of Programmable logic controller 1769 TW Digital input module 32 point. 25 Repairing of Programmable logic controller 1769 Analog input module 8C 0-10V 0-20 26 Repairing of Programmable logic controller 1769 Digital output module 32 point. 27 Repairing of Programmable logic controller 1769 Power unit. 28 Repairing of Programmable logic controller 1769 Compact I/O to DSl module. 29 Repairing of Programmable logic controller 1769CMPAC Logix processor ethernet 2MB 30 Repairing of Programmable logic controller 1969 Endcap right. 31 Inhouse Programmable logic controller software devlopment charges. 32 On site commissioning of hardware, testing the complete system, terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, termination of control cables as required. Cleaning of panel, tightening of all connections, etc complete. 33 Servicing and overhauling of programmable logic controller panels complete system. Servicing ,repairing of programmable logic controller panels by checking software routine, debugging software, analysing the ladder diagrams, checking hardware and relay module, terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, termination of control cables as required. Cleaning of panel, tightening of all connections, etc complete. 34 Repairing, servicing of electromagnetic flow meter a P/F main kit PCB b P/F single card c Panel weather proof including internal wiring and components d Service charges e Setting and callibration of flow meter 35 Reparing of On line UPS pure sine wave by dismanteling, trasportation and reinstalling after repairing complete. a 1KVA b 2KVA c 3KVA d 6KVA e 10KVA 36 Servicing of DG control panel by servicing of EPU unit, battery charger, setting of timer, making control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware procured from material list like voltmeter, ammeter, selector switches, connector, MCB, indicators, push buttons. Also tightening of connections and cleaning of panel complete. 37 Servicing and overhauling of battery charger panel Servicing and overhaulling of battery charger panel by checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, provided indicators, voltmeter, ammeter, selector switches termination of incoming outgoing cables as required. Cleaning of panel, tightening of all connections, cleaning of battery terminals, checking battery voltages, battery cable lugs, etc complete 38 Servicing of RO/UV/UF water purifier by changing/cleaning of carbon filter, pre filter, sedement filter candles, cleaning of water purifier etc complete. 39 Repairing in point wiring wiring for light fan instrument with ISI mark 2-1sq.mm, copper wire PVC insulated 1.1KV grade with necessary accessories as required complete. 40 Repairing in power point wiring with ISI mark 2-1.5 sq.mm, copper wire PVC insulated 1.1KV grade with necessary accessories as required complete. 41 Repairing of board with necessary accessories as required complete. 42 Installation of transformer with loading, unloading, transportation 43 Carrying out necessary tests before and after charging transformer upto full load to satisfaction by connecting earthing, incomming and outgoing cables etc complete. 44 Providing minor repairs to existing plumbing system. 45 Providing major repairs to existing plumbing system. 46 Tracing out fault in cable/cable kit/cubical, removing the connection of cable, taking insulation test. After fixing new cable/cable kit, making termination of the cable again taking insulation test and giving satisfactory test and trials, etc complete. 47 Dismantalling temporary hangging wires accessories, etc complete. 48 Chiselling of wall for laying cable / mains, clamping it properly and refilling the broken wall by using POP etc complete. 49 Repairing, servicing of synchronization panel by servicing of contactor by changing provided contact kits, coil, servicing of electronic controller, control relays terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, push buttons, voltmeter, ammeter, selector switches, termination of incoming outgoing cables as required. Also tightening of connections and cleaning of panel complete. 50 Annual Maintenance Contract for Power Genset includes routine check-up visits with following scope of work and all breakdown visits including spares and major repairs throughout the year. A 82.5KVA Gangapur Dam Pumping Station B 140KVA Shivaji Nagar WTP. C 250KVA Dwarka Pumping Station D 250KVA Gopalnagar Pumping Station E 400KVA Chehedi Pumping Station F 400KVA Nasikroad WTP. G 400KVA Gandhinagar WTP. H 400KVA Nilgiribag WTP. I 600KVA Panchavati WTP Scope of worka B check kit (oil filter set, fuel filter set) shall be changed as required. b Engine oil 15W40 suitable for genset shall be changed as required. c Air cleaner element shall be changed as required. d Coolant shall be filled and top up as required. e Checking temperature, removing leakages, checking battery voltage, battery charging voltage, output voltage, frequency, AVR, tappet setting for good performance of genset. f Routine checkup visits should be done monthly. g Apart from above scope of work all major works to be carried out including all spares of generator excluding panel, batteries as and when required through out the year except total engine failure, natural disaster like flood etc. 51 Transformer oil filtration 52 Making trench in soft soil for laying provided cable 53 Breaking bituminous/ concreate road by JCB/Tractor breaker complete. 54 Providing and casting in situ cement concrete M-15 / 1:2:4 of trap / granite / quartzite / gneiss metal, moulded or chamfered as per drawing or as directed for coping to plinth or parapet, including centering, form work, compacting, covering newly laid concrete by gunny bag, plastic or tarpaulin, roughening them if special finish is to be provided and curing and finishing if required etc. complete. (The cement mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Wooden planks / shuttering will not be allowed) 55 Providing and laying jointless a highly flexible elastometric coating for RCC / cementitious surface for terrace waterproofing on B.B. Coba / R.C.C, on perfectly clean surface (free from loose dust and foreign matter) application of 1st coat of Polydee- LM @ 700 gms/Square Metre and applying 2nd coat of Polydee-LM @ 700 gms/Square Metre and finishing complete. 56 Repairing, servicing of crane panel by servicing forward/reverse contactor. Checking control wiring, adjusting limit switches, giving satisfactory test and trials of control systems etc complete. 57 Dismantling, disconnecting connections of all cables of ATS starters as fer following details. a Up to 80 HP. b 80HP to 200HP c 200HP to 300HP. 58 Erection of ATS starter panel at desired place including loading unloading and transportation and grouting it properly, etc complete as fer following details a Up to 200 HP. b 200HP to 300HP. 59 Annual Electrical inspection, compliance, test reports of earthing, insulation test etc complete for substation. 60 Annual Maintenance Contract for surge arrestor includes routine checkup visits with following scope of work and all breakdown visits including all spares and major repairs throughout the year etc complete. a Checking of surge arrestor pnumatic system by checking valve, pressure gauge, level gauge, solenoid valve, servicing of surge arrestor tank component, giving test and trials of automatic functioning of magnetic level sensors, checking all pressure etc complete. b Checking of compressor piston ring, gasket, shaft, filter, oil seal, oil ring, discharge valve, inlet valve, oil filling/top up and giving satisfactory test & trials of compressor. i Compressor No-1 ii Compressor No-2 c Checking of control panel for surge arrestor unit by checking terminations, power and control wiring, lugs, tie, saddle, ferrules, bus bars, hardware insulator, gasket, indicators, voltmeter, ammeter, selector switches. Cleaning of panel, tightening of all connections etc complete. 61 Repairing servicing of VCB/VC by checking operating mechanism, alignment of contacts, applying jelly to various parts, tightening all connections, polishing contacts, checking auxiliary contacts, closing coils, terminal strips, VCB/VC operation, insulation tests and giving satisfactory test and trial complete. 62 Repairing servicing of control feeder panel for VCB/VC by checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, termination of incoming outgoing cables as required. Cleaning of panel, tightening of all connections etc complete. 63 Repairing servicing and attending breakdown of CG Lucy unit by checking operating mechanism, alignment of contacts, applying jelly to various parts, tightening all connections, polishing contacts, checking fuses, top up oil level, oil BDV test, CG Lucy operation, insulation tests and giving satisfactory test and trial complete. 64 Servicing of OLTC by checking operating mechanism, alignment, applying jelly to various parts, checking of control panel operations and replacement of provided indicators, switches, control fuses, hardware, insulator, gasket, polishing contacts, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, termination of incoming outgoing cables as required. Cleaning of panel, tightening of all connections etc complete.
Contract Date: Jun 10, 2026 Contract Value : 94.40 Lakh
Government Departments No of Bidders 3
Maharashtra View Result →
4.
Housing Urban and Rular Development #11132407 AOC
Electrical Repair and Renovation Works at Dewanhat BPHC,Cooch Behar.- 1 SUB-HEAD 1 : DismantlingCharges for dismantling the all existing fitting fixture, switch boards, DBs, Main switchs, wirings etc. 2 SUB-HEAD 2 : Main Switches & BusbarSupplying and fixing 415V Change over switch with SheetSteel enclosure on angle iron frame on wall with nuts bolts etc [ Make-Havells/L&T/Siemens ] 3 63A 4 Supplying & fixing sheet metal (16 SWG) Iron Clad Busbar chambers on angle iron frame on wall, incl. earthing attachment and painting as required – (As per Drawing no. 470 of PWD Specification Book – May 1991) 5 4 Bars 415 V, 100/125 A, Dimension ofCu. bars-4 Nos.x 15mm(Width)x3mm(thickness), Dimension ofSheet MetalBox 500 mm x 150 mm 6 SUB-HEAD 3--BDB,PDB,VTPN ETCSupplying and fixingdouble door Vertical TPN MCB Distribution board for Up to 160A MCCB incomer with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachmenMake - Legrand / L&T/ ABB / SIEMENS / Schneider ] 7 8 Way 8 Supplying and fixingdouble door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachmen 9 6 Way [Make - Legrand / L&T / ABB / SIEMENS / Schneider] 10 4 Way[ Make - Legrand/ L&T / ABB / SIEMENS / Schneider] 11 Supplying and fixing double door sheet steel (16SWG), powder coated cable end box forTPN DB horizontal/vertical enclosure with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish with nuts bolts etc incl. provision for earthing attachment 12 8 Way (vertical) 13 8 Way (horizontal) 14 S&F double-door SPN MCB Distribution Board with IP-42/43 protection,on wall. With the help of necessary fastening accessories[Make:Legrand/Equivalent Model of other approved brand as per direction of EIC.[Make: Legrand/Schneider/Siemens/Crabtree/ L&T] 15 (2+10) Way 16 (2+6) Way 17 Supplying and fixing 415 V Four Pole MCCB of Breaking capacity 25kA/35kA with fixed thermal and fixed magnetic / adjustable thermal and fixed magnetic setting in existing DBs / enclosure and necessary connection as per direction of EIC.[Make: Legrand/Schneider/Siemens/Crabtree/ L&T] 18 80A 19 Supplying and fixing240/415 VSP MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection as per direction of EIC.(Make: Legrand/Schneider/Siemens/Crabtree/ L&T] 20 6-32A 21 Supplying and fixing240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection as per direction of EIC.[Make: Legrand/Schneider/Siemens/Crabtree/ L&T] 22 63ATP 23 Supplying and fixing240/415 V , TP MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connectionas per direction of EIC[Make: Legrand/Schneider/Siemens/Crabtree/ L&T] 24 40A 25 Supplying and fixing 240/415V FP MCB Isolator on din rail of existing DBs and necessary connection as per direction of EIC. [Make:Legrand/Schneider/Siemens/Crabtree/ L&T) 26 63A 27 Supplying and fixing FP, 240/415 V MCB Isolator on din rail of existing DBs and necessary connection as per direction of EIC. [Make:Legrand/Schneider/Siemens/Crabtree/ L&T) 28 40A 29 Supplying and fixing 240/415 VDPMCB Isolator on din rail of existing DBs and necessary connection as per direction of EIC.[Make:Legrand/Schneider/Siemens/Crabtree/ L&T) 30 40A 31 SUB-HEAD 4--Supplying & Laying of CableSupply of2/4 Core XLPEInsulated & Sheathed Armoured stranded Aluminium Conductor cables for Working Voltage up to 1100 Volts of following sizes[Make Polycab / RR /KEI/ Havells/ Gloster as approved by E.I.C] 32 4 Core 25 Sq mm 33 4 Core 50 Sq mm 34 Laying of one No. cable above 35 sqmm andupto 185 sqmm in underground trench 460mm wide x 760mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per Mtr. including filling the space between the bricks and cable and also the trenchwith shifted soil, leveling up and restoring surface duly rammed 35 Laying of cable upto 3/4 core 25 sqmm on wall/surface incl. S & FMS saddles with earthing attachment in 10 SWG GI (Hot Dip)Wire, making holes etc. as necy. mending good damages and painting 36 Laying of cable from3/3½core 35 sqmm to 50 sqmm on wall/surface incl. S & FMS saddles with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making holes etc. as necy., mending good damages and painting 37 Laying of cable as below, after cutting floor/pavement/wall/ andmaking holes incl., embedding the cable at an average depth asbelow and mending good the damages to original finish incl.removing the rubbish 38 From 2.5 sqmm to 35 sqmm at an average depth of 75 mm in floor/pavement/wall etc. 39 Above 35 sqmm to 95 sqmm at an average depth of 100 mm in floor/pavement/ wall etc. 40 Supplying and fixing compression type gland complete with brassgland, brass ring & rubber ring for dust & moisture-proof entry ofXLPE/PVC armoured cables as below : 41 For 4 core 25 Sq mm 42 For 4 core 50 Sq mm 43 Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials : 44 For 4 core 25 Sq mm 45 For 4 core 50 Sq mm 46 SUB-HEAD 5--Distribution WiringDistribution wiring in 2 x 22/0.3 (1.5 sqmm) single core stranded FR PVC insulated & unsheathed copper wire (Polycab/Havells/Brand approved by EIC) in 20mm size PVC rigid conduit FR (Precision make,MMS), with 1x22/0.3 (1.5 sqmm) single core stranded FR PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Piano Key type switch fixed on MS CRC sheet metal (16 SWG) switch board cum JB on wall complete with 2 no. suitable size “Ph & N” copper bar incl. bakelite/Perspex (wall matching color) top cover 3 mm thick and incl. 175mmx100mmx65mm inspection box, making earthing attachment, painting the MS box and mending good the damages to original finis. 47 Average run 9 mtr 48 Distribution wiring in 1.1KV grade 2x22/0.3(1.5sqmm) single core stranded FR PVC insulated & unsheathed copper wire (approved make) partly in 20mm size PVC rigid conduit FR (Brand approved by EIC) [for horizontal run&above false ceiling portion only] and in19mm bore,3mm thick polythene pipe [for vertical run embedded in wall],with1x22/0.3 (1.5 sqmm) single core stranded FR PVC insulated & unsheathed copper wire forECC, to light/fan/call bell points with Piano Key type switch fixed on MS CRC sheet metal (16 SWG) switch board on wall complete with 2 no. “Ph &N”copper bar incl.bakelite/Perspex top cover 3mm thick and incl. 175x100x65mm inspection box, making earthing attachment, painting theMSbox andmending good the damages to original finish [PVCRigid Conduit only for horizontal run& above false ceiling and vertical run concealed] 49 Average run 9 mtr 50 Distribution wiring in 1.1 KV grade 22/0.3 (1.5 sqmm) single core stranded FR PVC insulated & unsheathed copper wire (Polycab/Havells/Brand approved by EIC) in 20mm size PVC rigid conduit FR (Precision make,MMS), with 1.1 KV grade 1 x 22/0.3 (1.5 sqmm) single core stranded FR PVC insulated & unsheathed copper wire as ECC, to 5A 3 pin flush type plug socket & Piano Key type switch fixed on MS CRC sheet metal (16 SWG) switch board cum JB on wall incl. bakelite/Perspex (wall matching color) top cover 3 mm thick and incl. painting the MS box and mending good the damages to original finish] 51 On Board 52 Cutting Channel of size (40 mm x 40 mm) on masonry wall by Electric operated cutting machine incl. supplying & fixing heavy gauge 19 mm, 3 mm thick Polythene pipe by means of anchoring chemical (Hilti/Sika) and GI U hooks of 8 SWG incl. supplying and drawing 18 SWG GI wire as Fish wire andmending good damages to original finish by using own tools and tackles [for vertical run embedded in wall ] 53 19 mm dia 3 mm thick polythene pipe without earth continuity wire 54 Supplying and fixing PVC Rigid Conduit FR [Precision Make] on wall, ceiling with saddles and other accessories as required and mending good damages to building works20 mm Size 55 25 mm Size 56 Supplying and Drawing 1.1 KV single core stranded FR PVC insulated & unsheathed single core stranded copper wire ((Polycab/Havells/KEI or Brand approved by EIC)) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required 57 3 x 22/0.3 (1.5 sqmm) 58 2 x 36/0.3 (2.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) as ECC. 59 2 x 56/0.3 (4 sqmm) + 1 x 36/0.3 (2.5 sqmm) as ECC. 60 2x84/0.3 (6 sqmm) + 1x56/0.3 (4 sqmm) as ECC 61 Distribution wiring in 1.1 KV single core stranded FR PVC insulated & unsheathed copper wire (Polycab/Havells/Brand approved by EIC) in 20mm size PVC rigid conduit FR (Precision make) incl. necy. fittings as required 62 2 x 22/0.3 (1.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) 63 2 x 36/0.3 (2.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) 64 2 x 56/0.3 (4 sqmm) + 1 x 36/0.3 (2.5 sqmm) 65 2x84/0.3 (6 sqmm) + 1x56/0.3 (4 sqmm) as ECC 66 Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. 67 1.5 sqmm 68 2.5sqmm. 69 4.0sqmm. 70 6.0sqmm. 71 SUB-HEAD 6 :Plug & SocketsSupply & Fixing Two nos.240 V, 6A, plug socket with separate Two nos. 6 A Piano key type switch (Anchor/Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F 150x100x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required. 72 Supply & Fixing 240 V, 20A, plug socket with separate 20 A Piano key type switch (Anchor/Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F 150x100x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required 73 Supply & Fixing 240 V, 3 nos. 6A, & 1 no. 20A plug socket with separate 3 nos. 6 A & 1 no. 20A Piano key type switch, indicator & 20A switch type SP MCB (Anchor/Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F 240x200x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required 74 Supply & Fixing Socket type fan regulator (Step type) (Anchor/Brand approved by EIC) on existing sheet metal switch board with bakelite/perspex top cover by screw after making housing for regulator knob by cutting bakelite/perspex top cover incl. making necy. connectionsetc. 75 Supplying & Fixing sheet metal inspection box (16 SWG) of the following sizes flushed in wall by housing the same after cutting brick wall incl. making earthing attachment, painting and mending good damages to building works 300 mm x 200 mm x 65 mm 76 Supply & Fixing bakelite / perspex top cover on existing switch board by Brass screws after making housing for switch by cutting bakelite / perspex cover and making necessary connections as required 77 SUB-HEAD 7---S & F OFLIGHT FITTINGSSupply and Delivery of 4 feet Industrial box typesingle LED tube fitting incl. Supply & Delivery of 1 no. 240V, 20 W LED Tube (Polycarbonate with heat sink) with glare free light distribution with CCT (5000K-6500K) having minimum luminous efficiency of 100 Lm/ Watt or better & 50,000 LED burning hours or more. [Make- Philips-Cat.No. TMC502 1xLED 22Wincluding LED tube T8 Cat. No 1200mm 18W865 T8 I-2100lm/ Crompton/ Wipro or manufacturer with own NABL accredited lab with valid test certificate] [LED lamps & accessories shall have BEE certification] 78 Supply and Delivery of 4 feet Industrial box type twin LED tube fitting incl. Supply & Delivery of 2 no. 240V, 20 W LED Tube (Polycarbonate with heat sink) with glare free light distribution with CCT (5000K-6500K) having minimum luminous efficiency of 105 Lm/ Watt or better & 50,000 LED burning hours or more. [Make- Philips-Cat.No. TMC502 2xLED 22W including LED tube T8 Cat. No 1200mm 18W865 T8 I-2100lm/ Crompton/ Wipro or manufacturer with own NABL accredited lab with valid test certificate] [LED lamps & accessories shall have BEE certification] 79 Fixing only single/twin florescent light fitting complete with all accessories Directly on wall/ceiling with HW block and suitablesize MS fastener, Ceiling plate, nipples etc. as required 80 Supply & Delivery of 240V,18 Watt recess mounted round LED downlight having following wattage, in white powder coated pressure die cast aluminium housing with glare free uniform illumination, suitable for 2 x 2 grid ceiling with CCT (5700K-6500K) having minimum luminous efficiency of 100 Lm/ Watt or better & 50,000 LED burning hours or more. [Make- Philips/ Crompton/ Wipro or manufacturer with own NABL accredited lab with valid test certificate] [LED lamps & accessories shall have BEE certification] 81 Supply & Delivery of 240V,36 Watt recess mounted 2x2 LED downlight having following wattage in white powder coated pressure die cast aluminium housing , with glare free uniform illumination, suitable for 2 x 2 grid ceiling with CCT (5700K-6500K) having minimum luminous efficiency of 100 Lm/ Watt or better & 50,000 LED burning hours or more. [Make- Philips/ Crompton/ Wipro or manufacturer with own NABL accredited lab with valid test certificate] [LED lamps & accessories shall have BEE certification] 82 SUB-HEAD 8---S & F OF FAN FITTINGSSupply & Delivery of 230V, 1-Ph, AC ceiling fan of follwing size incl. all accessories. 83 Sweep Size- 1400 mm (56), Wattage ≤ 60 Watt, R.PM ≤ 300, Air Delivery ≥ 250 C.M.M (Make:Orient PSPO NEWBREEZE Pearl Ivory or SUMMERCOOL Pearl Ivory/Usha-1star STRIKER/Crompton Riviera(Bianco) 84 Sweep Size- 1200 mm (48), Wattage ≤ 55 Watt, R.PM ≤ 350, Air Delivery ≥ 220 C.M.M (Make:Orient PSPO NEWBREEZE Pearl Ivory or SUMMERCOOL Pearl Ivory / crompton Riviera(Bianco)/UHSA 1-Star STRIKER) 85 Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc. incl. S&F connecting wire for down rod upto 30 cm incl. painting the rod with approved paint and making necessary connection as required by 2x1.5 sqmm flexible copper wire. 86 Supply & Delivery of 230V, 50Hz, 450 mm sweepheavy duty full metal body wall bracket fan having wattage ≤ 90 Watt, RPM ≤ 1325, Air Displacement (In CFM) ≥ 3550 complete with all accessories. (Make - Orient/Crompton/ EPC/Cinni) [BEE star rated] 87 Fixing only cabin fan on wall/ceiling by S&F rag bolts, nuts & washers (6 mm dia x 62 mm long) or as reqd. incl. S&F 24/0.20 PVC insulated flexible copper wire 0.5 mt. length 88 Supply & Delivery of 220V, Single Phase, 50 Hz A.C heavy duty exhaust fan of following sizes having complete metal body. (Make- EPC/ USHA/Orient CROMTON) [BEE star rated] 89 300 mm (12), 4 Blade, RPM ≤ 920 , Wattage ≤ 45 Watt, Sound level ≤ 46 dB, Air Displacement (In CFM) ≥ 750 90 230 mm (9), 4 Blade, RPM ≤ 1370 , Wattage ≤ 40 Watt, Sound level ≤ 49 dB, Air Displacement (In CFM) ≥ 440 91 Fixing only exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust of following diameter: 92 23 cm (9) 93 30 cm (12) 94 Fixing only louver shutter/cowl on wall with necy. bolts & nuts (6 mm dia x 62 mm long) For 23 cm (9) Exhaust fan 95 For 30 cm (12) Exhaust fan 96 SUB-HEAD 9 -- EARTHING INSTALLATIONEarthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire, with an average depth of 3.65 Mts. below the ground level (For soft Soil: By TATA-Medium GI pipe) 97 Excavation of soil for installation of Earth Electrode and filling & ramming. (Soft Soil) 98 Supplying & fixing earth busbar of galvanized(HotDip)MS flat 40mm x 6mmo nwall having clearance of 6mm from wall including providing drilled holes on the busbar complete with GI bolts,nuts, washers, spacing insulators etc. as required 99 Connecting the equipments body to earth busbar including S&F 20 mm x 3 mm galvanised (Hot Dip) MS flat on wall/floor with GI saddles as required and connection to equipments incl. drilling holes, with bolts, nuts, washers etc. 100 Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe 101 Connecting the equipments to earth busbar including S & F GI (Hot Dip) wire of size as below on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages No. 6 SWG 102 ADD GST @ 18.00% ON SUM OFAMOUNT Sl-01 to SL-53 i.e 18% on Rs. 815643.00 103 ADD Cess @ 1.00% ON SUM OFAMOUNT Sl-01 to SL 54 i.e @1% on Rs.962459.00
Contract Date: Sep 10, 2025 Contract Value : 8.54 Lakh
Government Departments No of Bidders 3
West Bengal View Result →
5.
Tourism #11101592 Price Bid
Tender for Civil Works , Clearing Grass And Removal Of Rubbish Upto A Distance Of 50 M Outside The Periphery Of The Area , Earthwork In Excavation By Mechanical Means (Hydraulic Excavator)/Manual Means Over Areas (Exceeding 30 Cm In Depth, 1.5 M In Width As Well As 10 Sq.M On Plan) Including Disposal Of Excavated Earth Lead Upto 50 M And Lift Upto 1.5M Disposed Earth To Be Leveled And Neatly Dressed Including Providing Barricading, Danger Lighting Guarding As Directed In A) All Kinds Of Soil , Earthwork In Excavation In Trenches For All Leads & Lifts In All Type Of Strata Comprising Of Any Type Of Materials Either In Full Or Part As The Case May Be Adopting Any Method/Methods As May Be Convenient As Permitted Excluding Blasting In All Conditions Such As Dry, Moist, Foul, Saturated, Submerged, Etc,. Including Dressing Of Sides, Planking & Strutting, Timbering ,Ramming Of Bottom ,Pumping And Bailing Out Water ,Barricading Danger Lighting Guarding, Getting Out Excavated Soil & Stacking As Directed By Engineer For All Leads & Lifts Etc. Complete , Refilling The Pipeline/Foundation Trenches Plinth Sides, Foundation Etc. With Available Excavated Earth In Layers Not Exceeding 20 Cm Depth Consolidating Each Layer Ramming And Watering Lead Upto 50 M And All Lifts And Disposal Of Surplus Earth As Directed By Engineer . , Rubble Packing With Hard Laterite Stone Under Floors Including Watering Ramming And Consolidating Etc. In Pipeline Trenches And Other Foundations Complete. , Laterite Masonry In Neatly Dressed Stones For 23 Cms Thick Masonry Walls In Cm. 1 : 5 (1 Cement : 5 Coarse Sand) In Foundation Upto Plinth Level , Laterite Masonry In Neatly Dressed Stones For 23 Cms Thick Masonry Walls In Cm. 1 : 5 (1 Cement : 5 Coarse Sand) In Foundation Upto Plinth Level For Laterite Masonry In All Sizes In Superstructure From Floor I Level Upto Floor V Level. , Providing & Laying Cement Concrete 1:2:4 (1 Cement: 2 Coarse Sand: 4 Graded Granitic Or Basaltic Stone Aggrt. 20 Mm. Nominal Size) Excluding Cost Of Centering, Shuttering And Finishing In:All Works Upto Plinth Level , Providing & Laying Cement Concrete 1:2:4 (1 Cement: 2 Coarse Sand: 4 Graded Granitic Or Basaltic Stone Aggrt. 20 Mm. Nominal Size) Excluding Cost Of Centering, Shuttering And Finishing In B) In Retaining Walls , Return Walls(Any Thk) Including Attached Pilasters, Columns, Piers, Abutments, Pillars, Posts, Struts, Buttresses, String Or Lacing Courses, Parapets, Coping Bed Blocks, Anchor Blocks, Plain Window Sills, Fillets Etc, Upto Floor Five Level. , Providing And Laying In Position (1:11/2:3) Reinforced Cement Conrete Excluding The Cost Of Centering, Shuttering, Finishing And Reinfrocement (1 Cement: 1½ Coarse Sand:3 Graded Stone Agg 20Mm Nominal Size) All Works Upto Plinth Level , Providing And Laying Upto Floor Five Level Cement Concrete 1:2:4 (1 Cement: 2 Coarse Sand: 4 Graded Granitic Or Basaltic Stone Aggregate 20 Mm Nominal Size) Including Smooth Finishing To Exposed Surfaces, With Cement Mortar 1:3 (1 Cement: 3 Fine Sand) Including Centering And Shuttering Etc.Moulding As In Cornices, Window Sills Etc. Exceeding 15 Cm In Girth. , Providing And Laying In Position Ready Mixed Concrete (Rmc) Manufactured In Fully Automatic Batching Plant And Transported To Site Of Work In Transit Mixer For A Lead Upto 10Kms Having Continious Agitated Mixer, Manufactured As Per Mix Design Of Specified Grade For Reinforced Cement Concrete Work Including Pumping Of R.M.C., From The Transit Mixer To The Site Of Laying, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement Including The Cost Of Admixtures In Recommended Porportions As Per Is : 9103 To Accelerate/Retard Setting Of Concrete, Improve Workability Without Imparing Strength And Durability As Per The Directions Of The Engineer-In-Charge. All Works Upto Floor V Level. M-25 Grade Of Concrete , Centering & Shuttering Including Strutting, Propping & Removal Of Forms For :Foundations, Footings, Bases For Columns , Centering & Shuttering Including Strutting, Propping & Removal Of Forms For :Vertical Surfaces Such As Retaing Walls, Return Walls, Partitions, Walls (Any Thickness) Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets And The Like , Centering & Shuttering Including Strutting, Propping & Removal Of Forms For :Columns, Piers, Pillars, Aburments, Posts And Struts (Square Rectangle Polygon In Plan) , Centering & Shuttering Including Strutting, Propping & Removal Of Forms For :Sides And Soffits Of Beams, Beam Haunchings, Cantilever, Girders, Bressumers And Lintels Plinth Beams Not Exceeding 1M In Depth , Centering & Shuttering Including Strutting, Propping & Removal Of Forms For :Suspended Floors, Roofs Landings, Shelves & Their Supports , Centering & Shuttering Including Strutting, Propping & Removal Of Forms For Sloping Or Battering Surface (Slabs, Beams, Louvers, Etc) Including Folded Plates. Cornices & Mouldings , Extra To Be Added For Additional Height In Centering, Shuttering Where Ever Required With Adequate Bracing, Propping Etc. Including Cost Of De- Shuttering And De-Centering At All Levels, Over A Height Of 3.5M, For Every Additional Height Of 1M Or Part Thereof. (Plan Area To Be Measured) Suspended Floors, Roofs, Landings, Beams And Balconies (Plan Area To Be Measured) , Providing Tmt Steel Reinforcement Bars Of (Sail, Tata. Vizag, Jsw Steel Ltd.) ) (Confirming To Is 1786 Of 1986) For Reinforced Cement Concrete Work (Conforming To I.S. 1786 Of 1986) Including Bending, Binding & Placing In Position In All The Floors Along With The Factory Made Precast Concrete Cover Blocks Of Specified Sizes Whose Compressive Strength Is Not Less Than That Of Surrounding Concrete In The Structural Member. , Steel Work In Built Up Tubular (Round, Square Or Rectangular Hollow Tubes Etc.) (Square Hollow Section (Shs) Is4923 /Rectangular Hollow Section (Rhs) Is4923/ Circular Hollow Section (Chs) Is1161 Closed Structural Steel Of (Sail, Tata. Vizag, Jsw ,Apollo Steel Ltd.) Make (Min Yeild Stress 310 Mpa)) Trusses Etc., Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer, Including Welding And Bolted With Special Shaped Washers Etc. Complete. , Providing Water Proofing Treatment Over The New Reinforced Cement Concrete Roofs Terrace Toilet By Spreading Cement Slurry Over The Reinforced Cement Concrete Slab And Laying Of 10Cms. Average Laterite Stone Ballast Coba With The Necessary Gradient For Easy Flow Of Rain Water And The Coba In Covered With Damp Proof Of Hindustan Water Proofing Co. Or Equivalent Jointless Water Proofing Plaster Of Mix 1:3 ( 1 Cement : 3 Find Sand), Finished Smooth With Wooden Trowel With False Marking Of 30 Cms Square. The Vertical Surface Of The Adjoining Walls Are To Be Treated Upto A Height Of 30Cms Including Rounding Of Junction (The Rate Includes For Complete Items Including Labour And Materials And Including Cost Of Initial Treatment Of Roof Slab As Follows. The Injunction Of Damp Proof Or Equivalent Compound With Cement Solution Will Be Given As And When Found Necessary For Filling Honey Comb, Cracks Etc. In The Reinforced Cement Concrete Slabs). Note: Cement Consumption 25 Kg/Sq.M. , Providing And Laying Flamed Finish Granite Stone Flooring In Required Design And Patterns, In Linear As Well As Curvilinear Portions Of The Building All Complete As Per The Architectural Drawings With 18 Mm Thick Stone Slab Over 20 Mm (Average) Thick Base Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) Laid And Jointed With Cement Slurry And Pointing With White Cement Slurry Admixed With Pigment Of Matching Shade Including Rubbing, Curing And Polishing Etc. All Complete As Specified And As Directed By The Engineer : Flamed Finish Granite Stone Slab. , Rounding Of Edges Of Marble Slab To Semi Circular Slope , Providing And Fixing 18 Mm Thick Gang Saw Cut, Mirror Polished, Premoulded And Prepolished, Machine Cut For Kitchen Platforms, Vanity Counters, Window Sills, Facias And Similar Locations Of Required Size, Approved Shade, Colour And Texture Laid Over 20 Mm Thick Base Cement Mortar 1:4 (1 Cement : 4 Coarse Sand), Joints Treated With White Cement, Mixed With Matching Pigment, Epoxy Touch Ups, Including Rubbing, Curing, Moulding And Polishing To Edges To Give High Gloss Finish Etc. Complete At All Levels. Granite Of Any Colour And Shade, Area Of Slab Over 0.50 Sqm. Jet Black , Supplying And Fixing Of Precast Reinforced Cement Concrete Slabs(Factory Made,The Factory Should Be Iso Certified And Registered Under Dirctorate Of Industries, Govt. Of India) At Site In Concrete Grade Of M-25 With 20 Mm Nominal Size Granitic Or Basaltic Aggregate, Consolidated By Means Of Mechanical Platform, Vibration Etc. With Lifting Hooks Of M.S. 10Mm Bars And Pvc Cups Including Cost Of Reincforcement, Certificate From Manufacturer Shall Be Produced Indicating Grade Of Concret And Minimum Content Of Steel In The Product Along With 5 Year Free Replacement Warranty In Case Of Breakage Complete And As Directed By Engineer -In -Charge. Size 600 X 500 X 75 Mm With Steel Reinforcement Not Less Than 2.25 Kg Per Unit , Providing And Laying Jet Black Mirror Polish Granite Flooring And Dado Over 20Mm Thick Base Of Cement Mortar 1:4 Laid Over And Jointed With Cement Slurry Including Rubbling Complete Granitic Slab (Jet Blck With Mirror Polish) 20 Mm Thick Add Q0% Wastage 1.00 , Providing And Laying Factory Made Shot Blasted Cement Concrete Interlocking Paver Block Of Minimum M35 Grade Made By Heavy Duty Block Making Machine With Strong Vibratory Compaction And Of Aprpoved Size And Design / Shape Laid In 50 Mm Thick Compacted Bed Of Coarse Sand, Filling The Joints With Coarse Sand, Etc. All Complete As Per The Direction Of Engineer.- In I, Wave, Rectangular, Square Etc. Shapes. The Products Should Comply To Is 15658:2006 And Manfucatured By Iso9001: 2008 Certified Plant. The Shot Blasting Should Be Done Using 0.4-0.5Mm Dia Steel Shots With A Speed Of 3200 Rpm. 60 Mm Thick In All Colours Except Grey (M35 Grade) , Kotah Stone Slab Flooring Over 20 Mm (Average) Thick Base Laid Over & Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab Including Rubbing & Complete With Base Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) A) 20 Mm Thick. , Providing And Fixing Colour Coated Galvulium Roofing Sheets Of 0.5Mm Thickness Including All The Accessories (Tata Make) But Excluding The Cost Of Purlins, Rafters, Trusses, Flashings Etc. Complete As Per The Directions Of The Engineer In Charge. , Add For Providing & Fixing Flashings -[Corners, Ridges, Valleys, Gable End & Trims] (Girth Upto610mm) Including All The Accessories Complete As Per The Directions Of The Engineer In Charge. , Providing And Fixing Prince Or Equivalent Make Pvc Swr Half Round Eaves Gutter With Bolts, Nuts And Flat Iron Brackets 40 X 3 Mm Size Complete.140 Mm Nominal Size , Extra For Providing Flat Iron Bracket 50 X 3 Mm Size Instead Of 40 X 3 Mm Size With Necessary Bolts Nuts, Washers Etc. For Fixing A.C. Gutters To Purlins. , Extra For Providing And Fixing Prince Or Equivalent Make Pvc Swr Short Stop Ends For Socketed Half Round Eaves Gutters. 140 Mm Nominal Size , Brick Work Using Common Burnt Building Bricks In Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) With Bricks Of Class Designation 40 Kg / Cm2 (Wire Cut Bricks) In Superstructure Upto Floor Five Level. , 18Mm Cement Plaster In Two Coats Under Layer 12Mm Thick Cement Plaster 1:5 ( 1 Cement : 5 Coarse Sand) And Top Layer 6Mm Thick With Cement Plaster 1: 3 (1 Cement : 3 Coarse Sand) Finished With Sponge. , Removing White Or Colour Wash By Scrapping, Sand Papering And Preparing Surface Smooth Including Necessary Repairs To Scratches Etc. Complete. , Forming & Finishing The 20 Mm Groove In Plastered Surface & Repair The Edges As Per Specifications And Directions Of The Engineer In Charge. , Painting Three Or More Coats With Acryllic Exterior Paint Of Approved Brand And Manufacture (Such As Weather Shield,Apex) Including Applying One Coat Of Cement Primer And One Coat Of Surface Treatment Etc. Complete. , Applying One Coat Of Cement Primer Of Approved Brand And Manufacture On Wall Surface. , Painting (Two Or More Coats) With Synthetic Enamel Paint Of Approved Brand And Manufacture In All Shade Or New Work Over And Under Coat Of Suitable Shade With Ordinary Paint Of Approved Brand And Manufacture To Give An Even Shade , Demolishing Laterite Stone Masonry In Cement Mortar Including Stacking Of Serviceable Material & Disposal Of Unserviceable Material Within 50 Mts. Lead. , Dismantling Steelwork In Built Up Sections In Angles, Tees, Flats And Channels Including All Gusset Plates Bolts, Nuts, Cutting Dismembering And Staking Within 50 Mts. Lead , Dismantling Doors, Windows And Clearestory Windows (Steel Or Wood) Shutters Including Chowkhats Architrave Holdfast Etc. Complete And Staking Within 50 Mt. Lead Of Area 3 Sq.M. And Below , Demolishing Cement Concrete 1:3:6 Or Richer Mix Including Disposal Of Material Within 50 M Lead , Taking Out Existing cement concrete Interlocking Paver Blocks From Footpath/ Central Verge, Includingremoval Of Rubbish Etc., Disposal Of Unserviceable Material To The Dumping Ground,For Which Payment Shall Be Made Separately And Stacking Of Serviceable Material Within 50 Metre Lead As Per Direction Of Engineer-In-Charg , Providing And Fixing Statues (Lion Statue 3D View) Made Up Of Pop Of Size 3.45Ft X 4Ft Including All Fitting Fixtures , Finish Should Be Similar To The Photo Features References,Concepts Of Historic Eras Including All Tools, Plants, Labour And Materials, Leads, Lifts Etc Complete. As Directed By Engineer-In-Charge. , Supplying & Planting Shrubs, Creepers, Ground Covers, As Listed Below As Per The Nursery Size (0.3 - 0.45 M Tall) Including Providing, Spreading Preparing Soil Mixture , Adding Fertilizers As Per Planting Schedule,Garden Earth, Manure And Cocopeat Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. Betel Nut Trees , Supplying & Planting Shrubs, Creepers, Ground Covers, As Listed Below As Per The Nursery Size (0.3 - 0.45 M Tall) Including Providing, Spreading Preparing Soil Mixture , Adding Fertilizers As Per Planting Schedule,Garden Earth, Manure And Cocopeat Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. Lawn Selection One , Supplying And Stacking Of Good Earth At Site Including Royalty And Carriage Upto 1 Km. (Earth Measured In Stacks Will Be Reduced By 20% For Payment). , Spreading Of Sludge, Dung Manure Or/And Good Earth In Required Thickness (Cost Of Sludge, Dung Manure Or/And Good Earth To Be Paid Separately). , Making Lawns Including Ploughing And Breaking Of Clod, Removal Of Rubbish, Dressing And Supplying Doobs Grass Roots And Planting At 15 Cm Apart, Including Supplying And Spreading Of Farm Yard Manure At Rate Of 0.18 Cum Per 100 Sqm. As Per Morth Specification 307 , Maintenance Of Lawns Or Turfing Of Slopes(Rough Grassing) For A Period Of One Year Including Watering Etc. As Per Morth Specification 307 , Providing, Installating And Commissioning Weather Proof, Shock Proof Arihant Or Equivalent Make Double annual rate contract Swing Using Galvanized Steel, Pure Polyester, Nylon, Natural Rubber & Finished With Metal Colours/Roto Colours/Frp Colours With Following Details Product Size: 3.2M X 1.5M,Play Area: 4.2M X 2.5M, Including Concrete Foundation, Holding Down Bolts, Grouting With Plain Cement Concrete Of Ratio (1:2:4) Etc Complete With One Year Warranty As Directed By Engineer-In-Charge. , Providing, Installating And Commissioning Weather Proof, Shock Proof Arihant Or Equivalent Make Double annual rate contract Swing Using Galvanized Steel, Pure Polyester, Nylon, Natural Rubber & Finished With Metal Colours/Roto Colours/Frp Colours With Following Details Product Size: 3.2M X 1.5M,Play Area: 4.2M X 2.5M, Including Concrete Foundation, Holding Down Bolts, Grouting With Plain Cement Concrete Of Ratio (1:2:4) Etc Complete With One Year Warranty As Directed By Engineer-In-Charge. , Electrical Works , Supply Of 4 Core Armoured Pvc Insulated, Pvc Sheathed Aluminium Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part Ii) With Latest Amendments Of Following Size. 4 Core 25 Sq.Mm , Supplying And Making Cable End Terminations With Brass Compression Gland And Copper Lugs For Following Sizes Of 4 Core Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade Complete As Required.4 X 25 Sq. Mm. , Supply Of 4 Core Armoured Pvc/Xlpe Insulated, Pvc Sheathed Aluminium Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size.4 Core 10 Sq.Mm , Supplying And Making Cable End Terminations With Brass Compression Gland And Copper Lugs For Folowing Sizes Of 4 Core Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade, Complete As Required.(4) 4 X 10 Sq. Mm. , Laying Of One Number Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Size Not Exceeding 25 Sq.Mm Direct In Ground Including Excavation In The Form Of A Trench As Per Cable Trench Drawing Provided By The Engineer-Incharge,Sand Cushioning With Screened Sand Bed Of 20Mm Thick , Protective Covering With Bricks Placed Lenghtwise On Top Of Cable All Over The Run And Backfilling The Excavated Earth Without Stones Or Hard Material And Making The Surface Proper With 15 Cm Crown On The Top Complete As Required. (B) In Rocky Strata , Supplying And Laying 25 Mm X 5 Mm Gi Strip In 40 Mm Dia Gi Pipe From Earth Electrode As Required , Supply Of 3 Core Armoured Pvc/Xlpe Insulated, Pvc Sheathed Aluminium Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size.3 Core 2.5 Sq.Mm , Earthing With Gi Earth Pipe 2 Mts Long 40 Mm Dia Medium Class With Isi Mark,Of Approved Brands, Including Accessories And Providing Masonry Enclosure With Ci/Rcc Cover Having Locking /Lifting Arrangement And Watering Pipe Etc. With Charcoal Or Coke And Salt) As Required As Per The Earthing Drawing Provided By The Engineer-Incharge.The Scope Of Work Includes The Following: A) Excavation Of Pit Of Size 1.0X1.0X 2.0 Mtrs(Min) And Disposal Of Excavated Soil. B) Class B Gi Pipe, 40Mm Diameter As Per Specifications. C) Charcoal/Salt As Per Specs. D) Refilling The Pit Of Size 1.0X1.0X 2.0 Mtrs(Min) With Soft Black Soil Of Minimum Resistivity I/C Transportation. E)Masonary Chamber With Proper Foundation, Cover Plate And Locking Arrangement. F) Testing Of Earth Value With Earth Megger And Certifications Of Its Value. Aluminium Tag With Embossed Earthing Value To Be Attached To The Pipe. G)Watering Arrangement.(A) In Rocky Strata , Extra For Using Salt And Charcoal For Pipe Earth Electrode As Required( 65 Kgs Of Charcoal And 5 Kgs Of Salt). , Supply Installation Testing and Commissioning of Outdoor Stand Mounted Feeder Pillar Made Up Of 16 Swg Crca Sheet With 32A Tpn Mcb Incomer, Single Dial Timer, 25A Cotactor For Automatic Switching Of Luminaries , Power Tool Control With 2 No. 9A Contactors And Raise Lower Push Button, Incoming 35 Sq.Mm And Outgoing 16 & 2.5Sq.Mm Terminals With Outgoing Mcbs 6 Nos. , Supply, Installation, Testing And Commissioning Of Architectural Designed Pole Of 3Mtr Height Post Top Pole Made Of Galvanised Iron Sections Of 114Mm & 60Mm Dia. This Architecturally Designed Pole Is Structurally Sound. Windspeed Considered In Design 50M/S, Is875:Part 3:1987•Material For Tubes Steel Of Grade Yst210.•Material For Base Plate Steel Of Grade E250 To Is2062; 2011. The Pole Will Be Provided With An Inbuilt Junction Box To Fix 32Amp Connectors & 6Amp Mcb Inside The Cut Window Of The Bottom Pipe The Inbuilt Box Should Have A Flush Door Of Suitable Size With Allenkey Locking On Bothside. The Decorative Pole Will Be Mounted On A Square Base Plate Of Size 200X200mm Having 10Mm Thickness. The Base Plate Shall Have 4 Hole Suitable For M16/450 Foundation Bolts Ensuring Firm Grouting In The Specially Designed Reinforced Cement Concrete Foundation. The Galvanized Zinc Coat Should Not Be Less Than 65+/ 10Microns. The Galvanised Pole Should Be Painted In 3Layer Coating (Coating Thickness Should Not Be Than 80Microns Minimum) In Which 1St Layer With Etch Primer, 2Nd Layer With Epoxy Zinc Primer & 3Rd Final Layer With Pu Paint With Overall 100 +/- 10 Microns. Including Foundation Bolts, Frp Connectors And Mcb Preferred Make:- Suncity,Reytek, Havells, Leksa, La Luminite, Dwarka Casting , K-Lite As Directed By The Engineer Incharge , Supply Installation Testing And Commissioning Of 40W Decorative Luminaire Made Of Spun Aluminium Body Withpressure Die-Cast Heat Management (Pdchm) And The Ip65 Opticalcompartment With High Power Led/S Is Comprised Of A Deep Drawnchemically Polished And Co-Extruded, Thermoformed Polycarbonate Protectorstabilized Agent Uv Rays Suitable For 50W Led. Fitting Shall Be Post Topmounting Type Fixture. System Wattage: 50W Led, Protection Class:Ip65,Driver Integral: Constant Current, Input Voltage: 230-240 Vac, Frequency:50-60Hz, Operating Voltage:1200- 277Vac, Operating Temperature: 0Deg To+50Deg C, Single Phase Ac Supply.● Light Source : Bridegelux, Ledlumens:6000Lm, Cri(Ra):80, Led Colour Temperature: 4000K, Lifespan:59,000 Hours,, ● Physical Body: Die Cast Aluminium Base, Bodyspun Aluminium, Diffuser: Convex Type Translucent / V Translucentpolycarbonate Glass, Mounting: Suitable For 48Mm Od Pipe, Finish: Powdercoated Black, ●Driver Power Factor:0.95, Thd:7.8%,Surge Protection:4Kv, Efficiency:87%. Fitting Should Have Inbuilt Driver With Efficiency 0.9And Having Surge Protection Device Of 4Kva And External Surge Protectiondevice Of 10Kva Make Philips. Leds Of Osram & Driver To Be Of Makephilips. Lm79-2019 Report To Be Provided.(Preferred Make:-:- Suncity,Reytek, Havells, Leksa, La Luminite, Dwarka Casting , K-Lite As Directed By The Engineer Incharge
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 4
6.
Housing Urban and Rular Development #11076972 AOC
Tender For Supply Installation Testing And Commissioning Of Dg Set For Ct Scan Department Allied electrical installation Work At Islampur Sd Hospital, Islampur, Uttar Dinajpur.- 1 Supply & Delivery at site on foundation incl Testing & commissioning of 125 KVA, 415V, 50Hz, 3Ø silent new DG Set incl. full tank HSD oil,comprising of Engine, alternator, separate AMF panel, Base frame, Fuel tank, Battery,CPCB IV+ complient Engine & Acoustic Enclosure having following specifications :- ( Conformance Standards -IS/IEC 60034-1,ISO 8528, ISO 3046, ISO 9001,) 2 Make: KOEL GREEN / Jackson - Cummins / Eicher / Mahindra / Catterpillar / Volvo penta 3 Engine Type: 4 stroke Diesel EngineRPM: 1500BHP: 156 or higherCanopy size (height w/o silencer ) in mm - 3950 x 1350 x 1425 or higherBore x Stroke: 107 mm x 124mmDuty: PRIMECooling: Liquid cooled with radiatorCylinder: 4 / 6 in lineCurrent - 174 amp 4 Aspiration: Turbo ChargedGovernor Type: ElectronicFuel Tank Capacity: 250 Ltrs or higherFuel consumption at 75% rated load with radiator or fan: 22 L/Hr or lessFuel consumption at 100% rated load with radiator or fan: 30 L/Hr or lessOverload Capacity: 10% over load for one hour for every 12 hours continuous running at full load or better. 5 Engine instrument Panel: Consisting of starting switch with key, Lube oil indicator, water temperature Indicator, RPM Indicator and Hour meter. 6 Safety Controls: Emergency Stop,Low lube oil pressure warning/shutdown, High engine water temp warning/ shutdown, sensor failure indicator, engine overspeed indicator, battery charging and low battery indicator. 7 Exhaust Silencer :Residential TypeExhaust pipe size- 4 inchExhaust temp- 488 °celsiusStarting System : 12V / 24V Starting system complete with starter motor, charging alternator with rectifier and cutout as per manufacturer standard. 8 Battery : Lead Acid, Low maintenance or SMF and confirming to relevant IS Specifications with LOW/HIGH Battery voltage and weak battery warning. 9 Alternator Make Koel Green /Stamford / Leroy somer / CG / Mahindra / GE 10 Rating: 415V, 3PH, 50Hz, 125 kVA, 1500 RPM having double layer stator winding & dynamically balanced RotorType : Brushless, self excited and self regulatedInsulation : Class HProtection: Screen Protected drip proof with min IP-23 Protection.RPM : 1500Voltage regulation:± 0.5%Winding Connection: Star with NeutralTotal Distortion factor: Less than 3%Total Harmonic distortion in O/P waveform: Less than 5% 11 AMF Panel ( CPRI APPROVED) :- 12 Cubical type floor mounted AMF Panel made from 14 SWG Sheet Steel, dust and vermin proof with locking features, duly pretreated, powder coated painted and aesthetically finish, suitable for controlling of 125 KVA DG set having following specifications:i) 200A AC 1 duty, FP power contactor and U/V release etc. - 2 Nos (Make: Legrand/Siemens /Schneider/ABB/L&T).ii) 200A, TP MCCB (Breaking Capacity: 50KA) with microprocessor based LSIG Protection.(Make: Legrand/Siemens /Schneider/ABB/L&T).iii) By-pass Changeover Switch of rated capacity.iv) On-delay timer for load change-over .v)Off-delay timer for engine shut offvi) Push button type engine ON/OFF Switch 13 vii) Battery Charger complete set with voltage regulator, booster selector switch, ON/OFF switch, voltmeter and ammeter for charging the battery from mains in addition to the battery charging alternator mentioned above.viii) Indicating Lamps: 05 No.s each indicating Mains ON, Load on Mains, Set Running, Load on Set and Battery Charger ON respectively.ix) A/V alarm for low lubricating oil pressure, high water temperature, start failure and DG over load.x) Mode Selector Switch for setting on AUTO/MANUAL/TEST.xi) Microprocessor based relay with composite meter for digital display of the following: 14 Generator Voltage/AC Mains VoltageGenerator current in all phasesFrequency and PF & EnergyIndication for alternator supplyRunning time indication : number of hours of operation, and service intervals and service due indications.The AMF Panel must be so designed to ensure trouble free performance and ensure switching over eklectrical load to DG within 15 Sec from the instant of mains failure. 15 Acoustic Enclosure: The DG Set should have integrated high quality acoustic enclosure at the manufacturing state itself as per CPCB-IV norms.Base frame : Common Iron channel fabricated base frame containing the engine and alternator mounted on AVM pads and having provision for lifting hook. 16 Terms & Conditions :- 17 (i) All materials, equipments & accessories must conform to relevant IS specifications. The DG Set to be supplied must be from the authorizedOEM of the respective Engine Manufacturer. 18 (ii)Necessary manufacturers test certificate for Diesel Engine, Alternator etc. Will have to submit in triplicate copy during delivery of the equipment. 19 (iii) Copy of Type Approval Certificate and Certificate of COP must be produced at the time of delivery issued from competent Authority (As per CPCB Norms). 20 (iv) Circuit Diagram for AMF Panel must be submitted from the Manufacturer/ OEM. 21 (v) The entire set must be warranted at least 15 months from the date of Delivery/12 months/ 5000 Hrs from the date of Commissioning whichever is earlier.However Engine & Alternator should be warranted of 2 years/5000 Hrs, whichever is earlier. 22 Supply of HSD Oil. 23 Supply of Lubricating Oil. 24 S & F exhaust pipe of 100 mm. dia MS black pipe (Thickness 4 mm) including connection with the existing silencer attached with the flexible coupler and S&F flange, nuts, bolts & washers etc. & necessary fixing materials etc. as required from DG set to nearest building (Horizontal Run) with suitable high temperature painting ( from DG sets to top of the building plus 3mtr or as per CPCB) for 125 KVA DG set as per direction of EIC. 25 S&F exhaust pipe of 150 mm. black pipe (thickness 4 mm.) including S&F flange, nuts, bolts & washers etc. as required from the nearest building wall to top of the building roof. (Vertical run) with suitable high temperature painting. 26 Making insulation by 2 glass wool including netting arrangement and covered with aluminium clading as per direction of the EIC. 27 a) 100 mm. dia exhaust pipe. 28 b) 150 mm dia exhaust pipe 29 c) Residential type silenser pipe 30 S & Erection of special type supporting arrangement for Exhaust pipe line with necessary foundation work as required as per site condition incl. S & F special type MS angle iron bracket/flat of required size as per OEM design with necessary nuts, bolts, welding arrangement etc. as required for the above exhahaust piping arrangement 31 S&F rain protection canopy made of GI sheet of 16 SWG. 32 S& delivery of 200 ltrs. Capacity heavy gauge MS sheet barrel. 33 Supply & delivery of best quality oil hand pump with 1 dia PVC flexible pipe (12 ft. approx.) 34 Supplying and fixing 415V, 250A,TPN on load front operated Changeover switch with Sheet Steel enclosure on angle iron frame on wall with nuts bolts etc.[D-2/3(a)] 35 Supplying & fixing medium gauge GI Pipe (ISI-Medium) Protection with necessary fittings and jointing metarials as required - 80mm dia 36 32 mm dia( for control cable) 37 Supply & Delivery of4 Core 120sqmm XLPEInsulated & Sheathed Armoured stranded Aluminium Conductor cables for Working Voltage up to 1100 Volts of following sizes [ Make Polycab / RR /KEI/ Havells as approved by E.I.C] 38 Laying of one No. cable above 35 sqmm andupto 185 sqmm in underground trench 460mm wide x 760mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per Mtr. including filling the space between the bricks and cable and also the trenchwith shifted soil, leveling up and restoring surface duly rammed.[F-2/1(b)] 39 Laying of cable above 3½ core 90 sqmm and upto 3½ core 150 sqmm on wall/surface including S & F MSclams with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making hole etc. as necy., mending good damages and painting 40 Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry ofXLPE/PVC armoured cables as below : 41 4Core 120 Sqmm. [F-4, 7/a] 42 Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials 43 4Core 120 Sqmm.[F-4, 7/a] 44 Supply & laying of 1.1 KV grade 12 core 2.5 sq.mm. PVC copper conductor control cable partly recessed and partly by shaddle on wall to interconnect DG set with AMF panel. 45 Supply & laying 1 x 50 sq. mm. single core flexible Al Armoured Cable in suitable size PVC pipe (reinforced) on wall / floor from neutral earth bus to DG set neutral point including both side socketing. 46 Excavation of soil for installation of Earth Electrode and filling & ramming. (For Soft Soil)[G-1/1(a)] 47 Earthing with 65 mm dia GI pipe (TATA-Medium)x 3.0 Mts.long and 1 No. 50 mm x 6 mm galvanized (Hot Dip) steel strip (4 Mts. long), 20 mm dia x 125 mm long galvanized bolt, double nuts, double washers including finishing both ends by making holes etc. and S & F 65 mm dia GI pipe (ISI-Medium) protection (3 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level to an average depth of 3.65 Mts(PWD-G1/2(d)) 48 Earthing with 50 mm dia ISI-Medium GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level. --- By ISI-Midium G.I Pipe 49 Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 50 mm x 6 mm on wall having clearance of 6 mm from wall includingproviding drilled holes on the busbar complete with GI bolts,nuts, washers, spacing insulators etc. as required.[G-2/4(c)] 50 Extra connecting the neutral of DG to earth electrode including S&F 50mmx6mm Galvanized(Hot Dip) steel strip on wall/floor with GI saddles & insulating the same by one layer of PVC strip over one layer of ampere tape. 51 Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe [G-2/3(a)] 52 Extra for treatment of soil by using salt & charcoal or coke for plate electrode. 53 Supply & fixing black PVC heat shrink sleeve for covering the 50 x 6 mm. GI flat. 54 Commissioning & testing of the Diesel Generator Set along with AMF panel with agencys own tools & tackles in presence of EIC. 55 Cutting RCC floor by special tools & tackles very carefully without any damaging and removing the shifted rubbish & levelling up and restoring the surface for 8 nos. earth-pit as per direction of EIC. 56 Supplying and fixing 4 way double door Horizontal TPN MCB Distribution board with IP-42/43 protection with 01 nos 415 V, 63A Four Pole MCB Isolator as incomer and 12 nos 240V, 16A-32A SP MCB of Breaking capacity 10kA & C characteristics on din rail ofDBs and necessary connection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment as to G.S. (Make: Seimens / ABB / L & T / Legrand)[D10/14, D5/6, D6/7] 57 Supply & Fixing, 250 V, 6-10A per way, 2+10 way SPN MCBDB with SS enclosure double-door with IP-42/43 protection with DP Isolators as Incoming & SPMCBs (C Curve, 10kA) as Outgoing, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire & Neutrallink & provision for earth attach for Enclosure (607712), 1 no 40A DP Isolator as Incoming, 10 nos 6-10A SPMCB as outgoing (Make: Seimens / ABB / L & T / Legrand) 58 Supply & Delivery of4 Core x 35sqmm XLPEInsulated & Sheathed Armoured stranded Aluminium Conductor cables for Working Voltage up to 1100 Volts of following sizes [ Make Polycab / RR /KEI/ Havells as approved by E.I.C] 59 Laying of cable from 3½ core 35 sqmm and upto 3½ core 50 sqmm on wall/surface including S & F MSclams with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making hole etc. as necy., mending good damages and painting 60 Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry ofXLPE/PVC armoured cables as below : 61 4Core 35 Sqmm. [F-4, 7/a] 62 Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials 63 4Core 35 Sqmm.[F-4, 7/a] 64 Distribution wiring in 1.1 KV single core stranded FR PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit FR (Precision make) incl. necy. fittings as required 65 2x84/0.3(6sqmm)+1x56/0.3(4sqmm) ECC. [E14:1(a)iv] 66 Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. 67 6sq mm.[F5:9(iii)] 68 4sq mm [F5:9(ii)] 69 Distn.wiringin 22/0.3 (1.5 sqmm) singlecorestrandedFR PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) in 19 mm bore, 3 mm thick polythen pipe (for horizontal & vertical run in wall andceling portion through prelaid polythen pipe) complete with all accessories embedded in wall to light/fan/call bell points with Piano key type switch (Anchor make) fixedon sheet metal (16 SWG) switch board with bakelite/perspex (wall matching colour) top cover (3 mm thick) flushed in wall incl. mending good damages to original finish.2x22/0.3 (Ph. & N) and 1x22/0.3 as ECC.avg run 9mtr[for substation wiring][E-10/3a(iv)] 70 Supply & Delivery of 230V, 1-Ph, AC ceiling fan of follwing size incl. safety wire , P2 capacitor and all accessories. (Make- Crompton / Usha / Orient/ Polar) [BEE star rated] -- Sweep Size- 1200 mm (48), Wattage ≤ 55 Watt, R.PM ≤ 350, Air Delivery ≥ 220 C.M.M 71 Fixing the above ceiling fan as per GS ( C-3/21a) 72 Supply & Fixing Socket type fan regulator (Step type) (Brand approved by EIC) on existing sheet metal switch board with bakelite/perspex top cover by screw after making housing for regulator knob by cutting bakelite/perspex top cover incl. making necy. connections etc.[E-10/3a(iv)] 73 Supply & Delivery of 220V, Single Phase, 50 Hz A.C heavy duty exhaust fan of following sizes having complete metal body. (Make- EPC/ USHA/Orient CROMTON) [BEE star rated]300 mm (12), 4 Blade, RPM ≤ 1420 , Wattage ≤ 82 Watt, Sound level ≤ 56 dB, Air Displacement (In CFM) ≥ 1120 74 Fixing only 12 inch exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust 75 Supply & Fixing Al louver shutter on wall with necy. bolts & nuts (6 mm dia x 62 mm long) -- 30 cm Exhaust fan (12) 76 Supply and Delivery of 4 feet Industrial box typesingle LED tube fitting incl. Supply & Delivery of 1 no. 240V, 20 W LED Tube (Polycarbonate with heat sink) with glare free light distribution with CCT (5000K-6500K) having minimum luminous efficiency of 100 Lm/ Watt or better & 50,000 LED burning hours or more. [Make- Philips/ Crompton/ Wipro or manufacturer with own NABL accredited lab with valid test certificate] [LED lamps & accessories shall have BEE certification] 77 Fixing only single/twin fluorescent light fitting suspended 25 cm below the ceilingwith 2 No. 20 mm dia EI conduit (14 SWG) supportsfixed with “U” type MS clamp whose both side fixed on ceiling with sutable size 4 nos. fastenerand other side connected with the conduit with suitable size of bolts and nuts incl. S&F EI conduit, “U” type (125mmx125mm) 6mm thick and 25mm with MS clamps and connecting the length of PVC insulated wire and mending good damages to original finish and painting etc. by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length. 78 Extra for suspension exceeding 25 cm with S&F additional 2 no. 20 mm dia EI conduit (14 SWG) supports & necy. PVC insulated wire and painting etc. as required by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length.
Contract Date: May 12, 2026 Contract Value : 20.92 Lakh
Government Departments No of Bidders 3
West Bengal View Result →
7.
Agriculture #10988522 Technical Bid
Tender for Earth Work In Excavation By Mechanical Means (Hydraulic Excavator )/ Manual Means In Foundation Trenches Or Drains (Not Exceeding 1.5 M In Width Or 10 Sqm On Plan) Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Taking Out The Excavated Soil And Depositing And Refilling Of Jhiri With Watering & Ramming And Disposal Of Surplus Excavated Soil As Directed With In A Lead Of 50 Meter. All Kinds Of Soils , Add Extra For Foundation/Trenches/Drains For Every Additional Lift Of 1.5 Mtr. Or Part Thereof In, All Kinds Of Soil , Supplying And Filling In Plinth With Blown Sand Under Floors Including Watering Ramming Consolidating And Dressing Complete Including Cost Of Sand. , Providing And Laying In Position Cement Concrete Including Curing, Compaction Etc. Complete In Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level. M10 Grade Nominal Mix 1: 3: 6 (1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20Mm Nominal Size). , Providing And Laying In Position Specified Grade Of Cement Concrete For All Reinforced Cement Concrete Structural Elements Upto Plinth Level Including Curing, Compaction, Finishing With Rendering In Cement Sand Mortar 1:3 (1 Cement: 3 Coarse Sand) And Making Good The Joints And Cost Of Plastizers( If Required) Excluding The Cost Of Centering, Shuttering And Reinforcement. M20 Grade Nominal Mix / Design Mix , Providing And Laying In Position Specified Grade Of Cement Concrete For Reinforced Cement Concrete Structural Elements Upto Floor Five Level Including Curing, Compaction, Finishing With Rendering In Cement Sand Mortar 1:3 (1 Cement: 3 Coarse Sand) And Making Good The Joints And Cost Of Plastizers (If Required ) Excluding The Cost Of Centering, Shuttering And Reinforcement For Walls (Any Thickness) Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc.M20 Grade Nominal Mix / Design Mix , Providing And Laying In Position Specified Grade Of Cement Concrete For Reinforced Cement Concrete Structural Elements Upto Floor Five Level Including Curing, Compaction, Finishing With Rendering In Cement Sand Mortar 1:3 (1 Cement: 3 Coarse Sand) And Making Good The Joints And Cost Of Plastizers( If Required) Excluding The Cost Of Centering, Shuttering And Reinforcement For Beams, Suspended Floors, Roofs, Griders Having Slopes Up To 15º, Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Windows Sills, Staircases And Spiral Staircases Etc.M20 Grade Nominal Mix / Design Mix , Centering And Shuttering With Plywood Or Steel Sheets Including Strutting, Propping Bracing Both Ways And Removal Of Formwork For Foundation , Footings, Strap Beam, Raft , Bases Of Columns Etc. , Centering & Shuttering With Plywood Or Steel Sheets Including Strutting, Propping Bracing Both Ways With Steel Props And Removal Of Formwork For Upto Floor Five Level For :Suspended Floors, Roofs, Landings, Staircases, Balconies, Girders, Cantilevers, Bands, Coping Bed Plates, Anchor Blocks, Sills, Chhajjas, Lintel, Beam, Plinth Beam Etc. , Centering & Shuttering With Plywood Or Steel Sheets Including Strutting, Propping Bracing Both Ways With Steel Props And Removal Of Formwork For Upto Floor Five Level For :Columns, Pillars, Posts And Struts Etc. , Providing And Fabricating Reinforcement For Reinforced Cement Concrete Work Including Straightening, Cutting, Bending, Placing In Position And Binding (Including Cost Of Binding Wire) All Complete Up To Floor Five Level. (Original Producers Who Manufacture Billet Directly From Iron Ores And Roll The Bilets To Produce Steel Conforming To Is:1786)Thermo-Mechanically Treated Bars (Conforming Of Relevent Is Code) , Add Extra For Providing Richer Mixes Respectively At All Floor Levels Providing M-25 Grade Concrete By Using Cement As Per Codal Provision Instead Of M-20 Grade Design Mix. , Random Rubble Stone Masonry For With Hard Stone In Foundation And Plinth In Cement Sand Mortar Above 30 Cm Thick Wall In:Cement Mortar 1:6 ( 1-Cement : 6-Sand). , Brick Work With Clay Flyash F.P.S. Brick (Is 13757- 1993 ) Of Class Designation 75 In Superstructure Above Plinth Level Upto Floor Five Level In : Cement Mortar 1 : 6 (1 Cement : 6 Coarse Sand) , Add Extra For Square Or Rectangular Pillars In Superstructre Brick Work Up To Five Storey Upto 45 Cm Length And Two Corners Are Free , Half Brick Work With Mechanised Autoclaved Flyash Lime Bricks Conforming To Is: 12894 :2002 Of Class Designation 75 In Superstructure Above Plinth Level Upto Floor V Level In. Cement Mortar 1 : 4 (1 Cement : 4 Coarse Sand) , Supplying And Fixing In Walls Machine Cut And Polished Stone Shelves, Tands And In Cm 1:3 With Machine Cut Edges : Kota Stone Minimum 30Mm Thick. , P & F 1St Qualityheavy Duty Vitrified Polished Digital Tiles On Floor, Skirting And Steps Etc.In Different Sizes (Thickness Minimum 10Mm) With Water Absortion Less Than Or Equal 0.08% And Conforming To Is 15622 Of Approved Make In All Colour And Shade, Laid With 20 Mm Thick Cm 1: 4 Including Grounting The Joints With White Cement And Matching Pigment Etc Complete.Size 600Mm X 600Mm , Providing And Fixing Granite Stone Slab Mirror Polished And Machine Edge Cut In Walls, Pillars, Steps, Shelves, Sills Counters, Floors Etc. Laid On 12Mm (Av.) Thick Base Of Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) Jointing With White Cement Mortar 1:2 (1White Cement : 2 Marble Dust) With Pigment To Match The Shade Of The Marble Slab Including Grinding, Rubbing And Polishing Complete. Jhunjhunu / Jalore (Red/Choclate/Black/Pink Colour) Above 3601 Cm2 Slabs , Extra For Providing Edge Moulding To 15-18Mm Thick Marble/ Granite/Kota Stone Counters, Vanities Etc. Including Machine Polishing To Edge To Give High Gloss Finish Etc. Complete As Per Design Approved By Engineer-In-Charge. Granite/Kota Stone Work Full Edge Moulding , Providing And Fixing 1St Quality Standard White, Grey, Ivory, Fume Red Brown, Light Green, Light Blue And Other Light Shades Glazed Tiles Confirming To Is : 13753 & Is :15622 Of Size 200Mm X 300Mm In Walls, Floors, Steps, Pillars Etc. Laid On A Bed Of Neat Cement Slurry Finished With Flush Pointing In The White Cement Mixed With Pigment To Match The Shade Of The Tile Complete (Excluding The Cost Of Cement Plaster On Walls And Pillar). , Providing And Fixing 1St Quality Mat Finished Ceremic Tile Size 300X300mm Confirming To Is : 13755 And Is : 15622 Colour Such As White, Grey, Ivory, Fume Red Brown, Light Green, Light Blue And Other Light Shades In Floors, Steps, Pillars Etc. Laid On A Bed Of Neat Cement Slurry Finished With Flush Pointing In The White Cement Mixed With Pigment To Match The Shade Of The Tile Complete (Including The Cost Of Cement Mortar Bed 1:4). , Extra For Using Size Above 200X300mm In Glazed Tiles And For Using 400Mm X 400Mm Mat Finished Tiles In Place Of 300Mm X 300Mm Size. Wall Tiles , Providing And Fixing External Grade Board Solid Core Single Leaf Flush Door Shutters Isi 2202-67 Marked Using Phenol Formal Dehyderesin In Glue Both Sides With Approved Steel Fittings Complete As Per Annexure A : 30 Mm Thick . Commercial Veneer Both Side , Extra For Providing External Lipping With 2Nd Class Teak Wood Battens 6 Mm Minimum Depth On All Edges Of Shutters (Over All Area Of Door Shutter To Be Measured) Over Item No. 8.13. , Providing And Fixing Pressed Steel Door Frames Confirming To Is 4351 Manufactured From Commercial Mild Steel Sheet Of 1.25 Mm Thickness Including Hinges Jamb, Lock Jamb, Bead And If Required Angle Threshold Of Mild Steel Angle Of Section 50X25mm, Or Base Ties Of 1.25Mm Pressed Mild Steel Welded Or Rigidly Fixed Together By Mechanical Means, Adjustable Lugs With Split End Tail To Each Jamb Including Steel Butt Hinges 2.5Mm Thick With Mortar Guards, Lock Strike-Plate And Shock Absorbers As Specified And Applying A Coat Of Approved Steel Primer After Pre-Treatment Of The Surface Including Filling With cement concrete 1:2:4(M15 Grade) Complete As Directed By Engineer-In-Chargeprofile C : , Providing And Fixing In Position Collapsible Steel Shutters With Vertical M.S. Channels 20 X 10 X 2Mm And Bracket With Flat Iron Diagonals 20 X 5Mm. Size With Top And Bottom Rail Of T-Iron 40 X 40 X 6Mm. With 40Mm Dia Steel Pulleys/Ball Bearing Complete With Bolts, Nuts Locking Arrangements Inside And Outside Stoppers, Handles Etc. As Per Specification Including Applying A Priming Coat Of Approved Steel Primer. (To Be Measured And Paid As Per Outer Dimension). , Providing And Fixing M.S. Sheet 1Mm Thick Single Leaf Door Shutter In Angle Iron Frame 35X35x5mm Suitabilly Diagonally Braced With 25X3mm Flat Iron Above And Below Lock Rail Of Size 50X5mm Beading Extra Including All Fittings, As Per Direction Of Engg. Incharge But Excluding Cost Of Chowkhats: Including Two Coats Of Anit-Corrosive Red Oxide Primer Paint , Providing And Fixing Steel Glazed Window Frame Made Out Of 80X40 Mm Hollow Sheet Section Of 16 Gauge Thickness, Joint Mitred Welded And Grinded Including Hold Fast Of Steel Lugs 13Mm X 3Mm And 15 Cm Long Embedded In C C Block 15 X 10 X 10 Cm Of 1:3:6 Nominal Concrete And Including Fixing Of Pivoted Hinges Of Superior Quality, Window Shutters Made Out Of 50 X 25.0 Mm Hollow Steel Section 15 Mm Paitam Of 18 Gauge Thickness, Joint Mitred And Grinded Including 10Mm X 10Mm Square Bars Welded To Frame For Paitam Fixing Float Glass 4Mm Thick Panes With Glazing Clips And Metal Sash Putty And Fixing Of Shutters Frames Peg Stay, U Shape Handle 100 Mm Long, Tower Bolts 100 Mm Long Of Steel Powder Coated Superior Quality Including Fixing And Jointing With Frame Hinges Priming Coat With Steel Primer Complete In All Respect As Per Direction Of Engineer-In -Charge , (A) Window Openable. , (B) Window Fixed. , Extra For Additional Shutter In Pipe Section Windows With Wire Gauge 14 Mesh X 24 Gauge , Providing And Fixing Square Bars Or Other Flat Welded To Window, Ventilatiors Etc. , Grading Roof For Water Proofing Treatment With Water Proffing Compound Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size) , Cement Concrete Flooring 1:2:4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate) Finished With A Floating Coat Of Neat Cement Including Cement Slurry, Making Of Lines Or Groove Etc Complete But Excluding The Cost Of Nosing Of Steps Etc. Complete. 75Mm Thick With 20Mm Thick Nominal Size Aggregate. , Chequerred Precast Cement Concrete Tiles 22 Mm Thick In Footpath & Courtyard Jointed With Neat Cement Slurry Mixed With Pigment To Match The Shade Of Tiles Including Rubbing And Cleaning Etc. Complete On 20 Mm Thick Bed Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) Dark Shade Using Ordinary Cement. , Providing And Fixing Of Double Leaf Steel Shutter For Cupboard, The Frame Is Made Of Pressed Steel Isi Section 80X25 Mmx 1.25 Mm Thick With 1.00 Mm Ms Sheet To Spot Welded Including Holdfasts Of 15X3mm, Ms Oxidized Fittings Such As Butt Hinges, Sliding Doors Bolts, Handles, Tower Bolts And Twin Peg Etc Complete Including Applying Priming Coat Of Approved Steel Primer Of Red Oxide Zinc Chromate And Spray Painting In Approved Shade With Deco Paint Of Approved Quality Complete As Per Direction Of Engineer In Charge , 6 Mm Thick Cement Plaster To Ceiling Of Mix 1:3 (1Cement : 3-Fine Sand) , Plaster On New Surface On Walls In Cement Sand Mortar 1:4 Including Racking Of Joints Etc. Complete Fine Finish :12Mm Thick . , Plaster On New Surface On Walls In Cement Sand Mortar 1:4 Including Racking Of Joints Etc. Complete Fine Finish : 20Mm Thick . , Providing And Applying White Cement Based Putty Over Plastered Surface To Prepare The Surface Even And Smooth Complete New Plastered Surface (Three Or More Coats) , Wall Painting With Plastic Emulsion Paint Of Approved Brand And Manufacture To Give An Even Shade Including All Scaffolding: Two Or More Coats On New Work Including Prepartion Of Base With Primer, Putty, Lippy Etc Complete In All Respect. , Finishing Walls With Acrylic Smooth Exterior Paint Of Required Shade Including All Scaffolding. New Work (Two Or More Coat Applied @ 1.67 Ltr/10 Sqm Over And Including Base Coat Of Water Proofing Cement Paint Applied @ 2.20 Kg/ 10 Sqm ). , Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture To Give An Even Shade : Two Or More Coats On New Work , Providing And Fixing Aluminum Work For Doors ,Windows, Ventilators And Partition With Extruded Built Up Standard Tubular / Appropriate Z Sections And Other Sections Of Approved Make Conforming To Is :733 And Is :1285, Fixed With Rawl Plugs And Screws Or With Fixing Clips ,Or With Expansion Hold Fasteners Including Necessary Filling Up Of Gap. At Junctions , At Top ,Bottom And Sides With Required Pvc/Neoprene Felt Etc. Aluminium Section Shall Be Smooth ,Rust Free, Straight ,Mitered And Jointed Mechanically Wherever Required Including Cleat Angle Aluminium Snap Beading For Glazing /Paneling , C.P. Brass/ Stainless Steel Screws Al. Tower Bolt & Al. Handle & Al. Aldrop Etc.,All Complete As Per Architectural Drawings And The Directions Of Engineer- In - Charge .(Glazing And Paneling To Be Paid For Separately).For Fixed Portion Powder Coating Aluminum ( Minimum Thickness Of Powder Coating 50 Micron) , Providing And Fixing Aluminum Work For Doors ,Windows, Ventilators And Partition With Extruded Built Up Standard Tubular / Appropriate Z Sections And Other Sections Of Approved Make Conforming To Is :733 And Is :1285, Fixed With Rawl Plugs And Screws Or With Fixing Clips ,Or With Expansion Hold Fasteners Including Necessary Filling Up Of Gap. At Junctions , At Top ,Bottom And Sides With Required Pvc/Neoprene Felt Etc. Aluminium Section Shall Be Smooth ,Rust Free, Straight ,Mitered And Jointed Mechanically Wherever Required Including Cleat Angle Aluminium Snap Beading For Glazing /Paneling , C.P. Brass/ Stainless Steel Screws Al. Tower Bolt & Al. Handle & Al. Aldrop Etc.,All Complete As Per Architectural Drawings And The Directions Of Engineer- In - Charge .(Glazing And Paneling To Be Paid For Separately).For Shutters Builtup Standard Tubular Sections Of Openable Doors ,Windows & Ventilators Including Providing & Fixing Hinges / Rollers Etc. And Making Provision For Fixing Of Fittings Wherever Required (Lockes Shall Be Paid For Separately). Powder Coating Aluminum ( Minimum Thickness Of Powder Coating 50 Micron) , Providing And Fixing Double Action Hydraulic Floor Spring Of Approved Brand And Manufacture Is : 6315 Marked, For Doors Including Cost Of Cutting Floors As Required, Embedding In Floors And Cover Plates With Brass Pivot And Single Piece M.S. With Stainless Steel Cover Plate , Providing And Fixing Glazing In Aluminium Door, Window ,Ventilator Shutters And Partitions Etc. With Pvs / Neoprene Gasket Etc. Complete As Per The Architectural Drawings And The Directions Of Engineer-In-Charge.(Cost Of Aluminium Snap Beading Shall Be Paid In Basic Item.)With Float Glass Panes Of 5.0 Mm Thickness ( Weight Not Less Than 13.50 Kg/Sqm) , Providing And Fixing Expanded Grill Made Of Aluminum As Per Design And Drawing Having Members Section Of Size 7.5Mm X 6.0Mm And Opening Of Size 102Mm X 99Mm To Aluminum Window/Vent With Required Screws, Y And H Aluminium Sec (As Per Drawing) At The Ends And Middle Joints Respectively Complete In All Respect As Per Direction Of Engineer In Charge.Powder Coating Aluminum ( Minimum Thickness Of Powder Coating 50 Micron) , Providing And Fixing 12 Mm Thick Prelaminated Three Layer Medium Density (Exterior Grade ) Particle Board Grade I, Type Ii Conforming To Is : 12823 Bonded Formaldehyde Synthetic Resin ,Of Approved Brand And Manufacture In Paneling Fixed In Aluminium Doors ,Windows Shutters And Partition Frames With C.P. Brass / Stainless Steel Screws Etc. Complete As Per Architectural Drawings And Direction Of Engineer-In-Charge.Pre-Laminated Particle Board With Decorative Lamination On One Side And Balancing Lamination On Other Side. , Providing And Fixing Curtain Rods Of 1.25 Mm Thick Chromium Plated Brass Plate, With Two Chromium Plated Brass Brackets Fixed With C.P. Brass Screws And Wooden Plugs, Etc., Wherever Necessary Complete: 20 Mm , Filling Available Excavated Earth (Excluding Rock) In Trenches, Plinth Side Of Foundation Etc. In Layers Not Exceeding 20 Cm. In Depth, Consolidating Each Deposited Layer By Ramming And Watering Including Lead Up To 50 Meter And With All Lift. , Carriage Of Earth Incloding Loading ,Unloading Without Stacking With Lea Of 5Km , Making Grooves As Per Design In Plaster 10Mm To 20Mm Wide. , Extra For Plastering Done On Moulding Cornices Or Architraves Including Neat Finish To Line And Level: In Two Coats , Providing & Fixing Uv Stabilised Fiberglass Reinforced Plastic Sheet Roofing Upto Any Pitch Including Fixing With Polymer Coated ‘J Or ‘L Hooks, Bolts & Nuts 8Mm Dia. G.I Plain/Bitumen Washers Complete But Excluding The Cost Of Purlins, Rafters, Trusses Etc. The Sheets Shall Be Manufactured Out Of 2400 Tex Panel Rovigs Incorporating Minimum 0.3% Ultra-Voilet Stabiliser In Resin System Under Approximately 2400 Psi And Hot Cured. They Shall Be Of Uniform Pigmentation And Thickness Without Air Pockets And Shall Confoim To Is 10192 And Is 12866.The Sheets Shall Be Opaque Or Translucent, Clear Or Pigmented, Textured Or Smooth As Specified.5.0Mm Thick (Wt. 8.4 Kg./Mtr. Sq.) , Providing Gola 75X75 Mm In Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand : 4 Stone Aggregate 10Mm And Down Gauge) Including Finishing With Cement Mortar 1:3 (1 Cement : 3 Fine Sand) As Per Standard Design : , Crazy Marble Stone Flooring 20Mm Thick Marble Stone With Black Or Of Specified Colour Topping Including Filling The Gaps With Cement Marble Chips Mix In Proportion Of 4 : 7 (4Cement : 7 White Black Or White Or Black Marble Chips) Size From 1Mm To 4Mm By Volume And Under Layer Of 25Mm Thick Cement Concrete [1:2:4, Graded Stone Aggregate 12.5Mm Nominal Size] Rubbing And Polishing And Cement Slurry Etc. Complete : In Ordinary Cement. , Extra In Marble/Other Flooring Work For Upto 50 Mm Wide Strip Of Green/White/ Jaisalmer Stone In Flooring Work As Per Direction Of Engineer In Charge , Providing & Fixing Precast Cement Concrete Coping 1 : 2 : 4 Mix 50Mm Thick Complete As Per Specification : , Renewing Glass Panes,With Putty And Nails Wherever Necessary Float Glass Panes Of Thickness 5 Mm , Filling Of Sunk Portion Of Roof With Earthen Pots Of Required Height Including Filling Voids With 1:3:6 Light Concrete, Using Brick Bats Complete Levelling And Dressing The Surface By 50Mm Thick Cement Concrete 1:2:4 As Per Specification. , Supply And Fixing In Cement Mortar Welded Hand Railing Made Out Of Ms Round Or Square Bars, Flats Etc. For Staircase Or Verandah As Per Design Complete In All Respect (Wooden Or Pvc Hand Railing To Be Paid Extra) With Priming Coat Of Red Oxide. , Extra For Providing D Type Pipe Head As Top Of Hand Railing , Providing And Fixing Almirah Lock (50 To 70 Mm Size )Of Approved Make Without Pair Of Handles For Door With Necessary Screws Etc Complete As Per Direction Of Engineer-In-Charge. , Providing And Fixing Stainless Steel Railing Made Of Hollow Tubes, Channels, Plates Etc., Including Welding, Grinding, Buffing, Polishing And Making Curvature (Wherever Required) And Fitting The Same With Necessary Stainless Steel Nuts And Bolts Complete, I/C Fixing The Railing With Necessary Accessories & Stainless Steel Dash Fasteners , Stainless Steel Bolts Etc., Of Required Size, On The Top Of The Floor Or The Side Of Waist Slab With Suitable Arrangement As Per Approval Of Engineer-In-Charge, (For Payment Purpose Only Weight Of Stainless Steel Members Shall Be Considered Excluding Fixing Accessories Such As Nuts, Bolts, Fasteners Etc.). Grade 304 , Lettering With Black Japan Paint Of Approved Brand And Manufacture. , Construction Of Granular Sub-Base By Providing Well Graded Material, Spreading In Uniform Layers With Tractor Mount Grader On Prepared Surface, Mixing By Mix In Place Method With Rotavator At Omc, And Compacting With Smooth Wheel Roller To Achieve The Desired Density, Complete As Per Morth Specification Clause 401..For Grading Iii Material , Construction Of Embankment With Approved Material Obtained From Borrow Pits With A Lift Upto 1.5 M, Transporting To Site, Spreading, Grading To Required Slope And Compacting To Meet Requirement Of Tables 300-1 And 300-2 With A Lead Upto 5.00Km As Per Morth Specification Clause 305.3 , Providing, Laying, Spreading And Compacting Graded Stone Aggregate To Wet Mix Macadam Specification Including Premixing The Material With Water At Omc In Mechanical Mixer (Pug Mill), Carriage Of Mixed Material By Tipper To Site, Laying In Uniform Layers In Sub-Base/Base Course On A Well Prepared Sub-Base And Compacting With Smooth Wheel Roller Of 80 To 100Kn Weight To Achieve The Desired Density Including Lighting, Barricading And Maintenance Of Diversion, Etc As Per Tables 400-12 & 400-13 And Morth Specification Clause 406.By Mechanical Means With All Lead , Providing And Laying Of Interlocking M-30 Grade Concrete Block Pavements Having Thickness 80 Mm As Per Drawings And As Per Is 15658:2006.And All Materials Shall Conform To Morth Specification Clause 602.With M-30 Grade 0.30 Mtr X 0.30 Mtr X 0.15 Mtr Edge Blockscategory B : Dentated Only Two Side Like I,Z,T Shape As Per Irc:Sp:63-2004 , Construction Of Tube-Well From Ground Levels And Upto 100 Meter Depth And Above To Accommodate Housing And Assembly Pipe Of Following Sizes In All Types Of Alluvium Strata By Percussion/ Rotary Drilling Method And With Gravel As Per Is:4097-1967 And Packing As Per Is:2800 (Part I -& Ii) 1979 As Amended Upto Date (The Work Includes The Cost Of Gravel & Its Primary Packing And Packing During Development, Lowering Of Housing & Strainer Assembly Pipes, With Supply And Wrapping Of Coir-Rope, Wherever Necessary, For Arresting Fine Sand Particles. The Work Will Not Include Cost Of Housing Pipe And Strainer Pipe Assembly And Development Work, But Work Would Be Completed After Obtaining Sand Free Water).200Mm Dia. Nominal Bore. , Construction Of Tube-Well Upto 100 Meter Depth And Above In All Type Of Rocks By Dth System And Over Burden, To Accommodate Casing Pipe Of Following Sizes In All Types Of Soils And Over Burden Including Lowering Of Casing Pipes, But Excluding Cost Of Casing Pipes As Per Is : 2800 (Part I & Ii) 1979 Specifications. The Work Would Be Completed After Obtaining Sand Free Water. The Tube Well Should Have A Throughout Bore As Per Nominal Dia Of Casing Pipe: 200Mm Dia. , Supply Of Strainer Pipes Made Of Erw M.S. Black Pipe Isi Mark Of Following Sizes At The Site Of Work Including Required Size Of Slotting As Per Is:8110-1985. 200Mm Normianl Bore , Supply Of Erw M.S. Black Casing Pipe Isi Marked Is:4270/ 1992) Of Grade Fe410 Of Following Sizes At Site Of Work. 200Mm Normianl Bore , Development Of Tube Well As Per Is Specification Using Suitable Compressor To Give Sand Free Water For Required Yield Of The Gravel Packed Tube Well. , S & F Tube Well Cover Of M.S.Sheet (6Mm Thick) With Nuts And Bolts Complete For Casing Size:200Mm Dia. , S & F M.S. Clamp, Set Of 50 ×6Mm Flat Iron With Nuts And Bolts Etc. For Holding The Riser Pipe Assembly Of Submersible Pump Set. , P & F Indian Type White Glazed Vitreous China 1St Quality W.C. Orissa Pan (Is :2556 Mark) With 100 Mm Vitreous China P Or S Trap Including Cutting And Making Good The Wall And Floor: Size 580X440mm. , P & F European Type White Glazed Vitreous China 1St Quality Double Syphonic W.C (Is :2556 Mark) With P Or S Trap Including Cutting And Making Good The Wall And Floor , P & F Water Closet Seat Covers With Brass Hinges Complete :Solid Pvc (Is 2548 Marked) Grade-I Black For Ewc. , P & F Low Level Flushing Cistern Of 10 Litres Capacity (Is : 2556 Mark) Of Approved Make With Complete Fittings C.I. Brackets Duly Painted, Brass Ball Cock With Ball (Is: 1703 Mark) Complete Including Cutting And Making Good The Wall: Pvc With Pvc Bend And Superior Internal Fittings As Per Is : 7231 . , P & F Flush Pipe Of Approved Make With Complete Fittings For High Level Flushing Cistern: Pvc Exposed (Heavy) 32Mm. , P & F Wvc Wash Basin (Ist Quality Is:2556 Mark) Of Approved Make With C.I. Brackets Duly Painted 1 No. 15 Mm C.P. Pillar Cock (Is:8934 Mark) & 32 Mm C.P. Brass Waste Coupling Of Approved Make, P.V.C Waste Pipe With Pvc Nut 32 Mm Complete Including Cutting & Making Good The Wall : , Size 580 Mm X 450 Mm , Size 630 Mm X 500 Mm Dia For Counter Top , P & F Bevelled Edge Mirror/Mirror With Teak Wood Lipping Around Of Special Glass Of Approved Make As Per Direction Of Engineer-In-Charge Complete With 6Mm Thick Commercial Ply Base Fixed To Wooden Screws & Washers. Size 600 X 450Mm X 4 Mm Thick , P & F Towel Rail Or Ring Of Approved Quality/Make: , C.P. Brass Towel Rail Elbow Type With Concealed Screws Size 450Mm (Heavy Duty). , P & F Grating Of Approved Quality/Make: , Stainless Steel Sheet Size 125Mm Dia. , P & F Liquid Soap Container With Brackets Complete Of Approved Make: , P & F Jet Spray For Water Closet With C.P. Copper Tube Flange Of Approved Make. , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes (Is 15778 : 2007 Code) Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings I/C Fixing The Pipe With Clamps At 1 Metre Spacing. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer In Charge. (Internal Work Exposed On Wall) , 20 Mm Nominal Outer Dia Pipes , 25 Mm Nominal Outer Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes (Is 15778 : 2007 Code) Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings I/C Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement And The Cost Of Cutting Chases And Making Good The Same Including Testing Of Joints Complete As Per Direction Of Engineer In Charge. (Concealed Work Including Cutting Chases And Making Good The Walls Etc.,) , 20 Mm Nominal Outer Dia Pipes , 25 Mm Nominal Outer Dia Pipes , Making Connection Of G.I. Distribution Branch With G.I. Main Including All Fitting. , Upto 25Mm Dia , P & F Bib Cock (Is : 8931 Mark), Superior Quality Of Approved Make: , C.P. Brass Bib Cock,15Mm Nominal Bore. , C.P. Brass Bib Cock Long Body, 15Mm Nominal Bore Weight Not Less Than 690 Gm , P & F Ball Cock (Is :1703 Mark) With Rod & P.V.C. Ball Complete : Brass Wt. Not Less Than 300 Gm,15Mm. , P & F Inlet Connection (Angle Valves) Superior Quality, Of Approved Make, For Wash Basin, Gyser Etc. C.P. Inlet Connection 15Mm.Brass (Is : 8931 Marked) , P & F 15 Mm. Dia Connection Pipe Of Approved Quality/Make : Pvc Pipe With C.P. Brass Nuts Upto Length 450Mm. , P & F Full-Way Valve (Is:778 Mark) Or Wheel Valve Of Approved Make : , Gun-Metal 15Mm Nominal Bore. , Gun-Metal 25Mm Nominal Bore. , P & F Pvc Storage Tank Isi Marked (Is : 12701) Indicating The Bis License No), Of Approved Make With Cover, 25Mm Dia 1M Long G.I. Over-Flow Pipe & 25 Cm. Long Wash Out Pipe With Plug & Socket, Including Making Connection Etc., Complete Of Approved Design: 1000 Litres Capacity , P&F Rigid Pvc Pipe (Is:4985 Mark) Class Ii/ (4 Kg. /Cm2.) Approved Quality /Make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant. 160 Mm Dia , P & F S.W. Master Trap (Inter-Cepting) A Grade (I.S.: 651 Marked) Of Approved Quality/Make 150Mm Dia , P&F Rigid Pvc Pipe (Is:4985 Mark) Class Ii/ (4 Kg. /Cm2.) Approved Quality /Make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant. 110 Mm Dia , P&F Rigid Pvc Pipe Fittings (Is: 4985 Mark) Of Approved Quality /Make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant: 110Mm Dia , Coupler (Socket) , Plain Tee , Bend 45 , Vent Cowel , Pipe Clip , Multi Floor Trap , Construction Of Manhole In All Type Of Soil Inner Size 90 X 60 Cm. 300 Mm Thick Masonry In Cm 1:6, 10 Cm. Thick Cement Concrete 1:5:10 In Foundation, 20 Mm Thick Inside Plaster In Cm 1:6, Finished With Floating Neat Cement, 50Mm Thick M-15 Grade cement concrete Flooring, Making Channels, 80Mm Thick Stone Slab Covering With 40Mm Thick M-15 Grade cement concrete Flooring, Cement Cover With Frame Of 450Mm Dia, Earthwork Etc. Complete As Per Design Including Disposal Of Surplus Earth Within 50 Mtr. Lead. Depth Up To 0.5 M , Construction Of Chamber In All Type Of Soil With 300 Mm Thick Masonry In Cm 1:6 M,10 Cm Thick cement concrete 1:5:10 In Foundation, 20Mm Thick Insider Plaster In Cm 1:6, Finished With Floating Neat Cement, 50Mm Thick M-15 Grade cement concrete Flooring , Earthwork Etc. Complete As Per Design Including Disposal Of Surplus Earth Within A Lead Of 50 Mtr. -Do- Size 600 X 450Mm Depth Upto 0.5 M Cement Cover With Frame. , Construction Of Septic Tank In All Types Of Soil With 40 Cm .Thick Masonry In Cm 1:6, 15 Cm Thick cement concrete Bed Of 1:5:10, M-15 Grade cement concrete Floor & Reinforced Cement Concrete Slab Covering With M15 Grade cement concrete Floor, 50 Mm Thick Stone Slab Partition Walls, 20 Mm Thick Plaster In Cm 1:6 Finished With Neat Floating Cement, 4 Nos Stone Foot Rests Of Approved Design ,Two No. 450 Mm Dia Each Ferro Cement Cover With Frame, Earth Work Etc. Complete As Per Approved Drawing Including Disposal Of Surplus Earth Within A Lead Of 50 Mtr:- Size 400 X140x150 Cm.(For 50 Users) With 115 Mm Thick Reinforced Cement Concrete (M-20) Slab With Tor Steel Reinforcement 10Mm Φ @15 Cm C/C Bothways Including Shuttering Complete In All Respect. , Construction Of Recharge Shaft In Filter Pit Including Earth Work Excavation , Lifting Excavted Earth With All Lift And 50 M Lead And Centering & Shuttering Evenever Required.Diameter 900 Mm , Supply & Fixing Pre-Cast Reinforced Cement Concrete Rinngs At The Mouth Of Recharge Shaft Of M20 Mix With 40 Mm Thicknessdiameter 900 Mm , Earth Work In Excavation By Mechanical Means (Hydraulic Excavator )/ Manual Means In Foundation Trenches Or Drains (Not Exceeding 1.5 M In Width Or 10 Sqm On Plan) Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Taking Out The Excavated Soil And Depositing And Refilling Of Jhiri With Watering & Ramming And Disposal Of Surplus Excavated Soil As Directed With In A Lead Of 50 Meter. All Kinds Of Soils , Add Extra For Foundation/Trenches/Drains For Every Additional Lift Of 1.5 Mtr. Or Part Thereof In All Kinds Of Soil , Providing And Laying In Position Cement Concrete Including Curing, Compaction Etc. Complete In Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level. M10 Grade Nominal Mix 1: 3: 6 (1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20Mm Nominal Size). , Random Rubble Stone Masonry For With Hard Stone In Foundation And Plinth In Cement Sand Mortar Above 30 Cm Thick Wall In:Cement Mortar 1:6 ( 1-Cement : 6-Sand). , Plaster On New Surface On Walls In Cement Sand Mortar 1:4 Including Racking Of Joints Etc. Complete Fine Finish :20Mm Thick . , Finishing With Neat Cement (Punning). , Providing And Laying In Position Specified Grade Of Cement Concrete For Reinforced Cement Concrete Structural Elements Upto Floor Five Level Including Curing, Compaction, Finishing With Rendering In Cement Sand Mortar 1:3 (1 Cement: 3 Coarse Sand) And Making Good The Joints And Cost Of Plastizers( If Required) Excluding The Cost Of Centering, Shuttering And Reinforcement For Beams, Suspended Floors, Roofs, Griders Having Slopes Up To 15º, Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Windows Sills, Staircases And Spiral Staircases Etc. M20 Grade Nominal Mix / Design Mix. , Add Extra For Providing Richer Mixes Respectively At All Floor Levels, Providing M-25 Grade Concrete By Using Min 410 Kg Of Cement Per Cum Instead Of M-20 Grade Design Mix. , Centering & Shuttering With Plywood Or Steel Sheets Including Strutting, Propping Bracing Both Ways With Steel Props And Removal Of Formwork For Upto Floor Five Level For : Suspended Floors, Roofs, Landings, Staircases, Balconies, Girders, Cantilevers, Bands, Coping Bed Plates, Anchor Blocks, Sills, Chhajjas, Lintel, Beam, Plinth Beam Etc. , Providing And Fabricating Reinforcement For Reinforced Cement Concrete Work Including Straightening, Cutting, Bending, Placing In Position And Binding (Including Cost Of Binding Wire) All Complete Up To Floor Five Level. Thermo-Mechanically Treated Bars (Conforming Of Relevent Is Code). , Cement Concrete Flooring 1:2:4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate) Finished With A Floating Coat Of Neat Cement Including Cement Slurry, Making Of Lines Or Groove Etc Complete But Excluding The Cost Of Nosing Of Steps Etc. Complete. 75Mm Thick With 20Mm Thick Nominal Size Aggregate. , Structural Steel Work Riveted, Bolted Or Welded In Built Up Sections, Trusses And Framed Work, Including Cutting, Hoisting (Height Upto 10 M) , Fixing In Position And Applying A Priming Coat Of Approved Steel Primer All Complete: , Inside Size 600X450mm Upto Depth Of 0.5M & 38Kg Ci Cover With Frame , 250Mm Dia Internal. , P&F Rigid Pvc Pipe (Is:4985 Mark) Class Ii(4 Kg. /Cm.) Approved Quality /Make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant, 160Mm Dia. , 250Mm Dia S.W. Pipe. , P & F 60 Cm. Wide M.S. Ladder In Open Well Made Of Flat Iron 32X5mm And 10Mm Dia Bars @ 200Mm C/C With Angle Iron Hold Fasts At Suitable Interval Complete As Per Drawing. , Construction Of Tube-Well From Ground Levels And Upto 100 Meter Depth And Above To Accommodate Housing And Assembly Pipe Of Following Sizes In All Types Of Alluvium Strata By Percussion/ Rotary Drilling Method And With Gravel As Per Is:4097-1967 And Packing As Per Is:2800 (Part I -& Ii) 1979 As Amended Upto Date (The Work Includes The Cost Of Gravel & Its Primary Packing And Packing During Development, Lowering Of Housing & Strainer Assembly Pipes, With Supply And Wrapping Of Coir-Rope, Wherever Necessary, For Arresting Fine Sand Particles. The Work Will Not Include Cost Of Housing Pipe And Strainer Pipe Assembly And Development Work, But Work Would Be Completed After Obtaining Sand Free Water).200Mm Nominal Bore , P & F G.I. Pipes (Internal Work) With G.I. Fittings (Is:1239-1992 Mark) & M.S. Clamps Including Cutting And Making Good The Walls And Floors : Exposed On Wall, 15 Mm Dia Nominal Bore. B - Class. , Supply Of Strainer Pipes Made Of Erw M.S. Black Pipe Isi Mark Of Following Sizes At The Site Of Work Including Required Size Of Slotting As Per Is:8110-1985. , Size 9 To 12 Mm , Size 3 To 5 Mm , Wiring Of Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Conductor 1.1 Kv Grade And 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Earth Conductor 1.1 Kv Grade (Is:694) In Recessed Isi Marked Mms ( Is:9537 P - Iii ) Virgin Material Pvc Conduit & Its Isi Marked (Is:3419-1988) Accessories, Round Tiles, 1.2 Mm Thick Hot Dipped Galvanized Modular Box With Earth Terminal, 10A Modular Switch,Modular Face Plate With Grid Plate, 3 Pin Ceiling Rose / Holder /3 Way Connector, Screws, Making Connections, Testing Etc. As Required. For Specification Of Copper Conductor, Phenolic Laminated Sheets & Electrical/ Wiring Accessories Refer Chapter E - 04, E - 05 & E - 07 For Additional Technical Parameters Of Product / Work Refer Annexure A Attached. , Short Point (Up To 3 Mtr.) , Medium Point (Up To 6 Mtr.) , Long Point (Up To 10 Mtr.) , Wiring Of Twin Control Light Point With 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Conductor 1.1 Kv Grade And 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Earth Conductor 1.1 Kv Grade (Is:694) In Recessed Isi Marked Mms ( Is:9537 P - Iii ) Pvc Conduit & Its Isi Marked (Is:3419-1988) Accessories, Round Tiles, 2 Nos Hot Dipped Galvanized M.S Modular Box Of 1.2 Mm Thick With Earth Terminal,2 Nos10 A Two Way Modular Switch, 3 Pin Ceiling Rose / Holder / 3 Way Connector ,Modular Face Plate With Grid Plate, Screws, Making Connections, Testing Etc. As Required. For Specification Of Copper Conductor, Phenolic Laminated Sheets & Electrical/ Wiring Accessories Refer Chapter E - 04, E - 05 & E - 07 For Additional Technical Parameters Of Product / Work Refer Annexure A Attached . , Medium Point (Up To 6 Mtr.) , Long Point (Up To 10 Mtr..) , Wiring Of 3/5 Pin 6 Amp. Light Plug Point With 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Conductor 1.1 Kv Grade And 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Earth Conductor 1.1 Kv Grade(Is:694) In Recessed Isi Marked Mms ( Is:9537 P - Iii ) Pvc Conduit & Its Isi Marked (Is:3419-1988)Accessories, Hot Dipped Galvanized Modular Box Of 1.2 Mm Thick With Earth Terminal, 10 A Modular Switch, 3/5 Pin 6 A Modular Socket, Modular Face Plate With Grid Plate, Screws, Making Connections, Testing Etc. As Required. For Specification Of Copper Conductor, Phenolic Laminated Sheets & Electrical/ Wiring Accessories Refer Chapter E - 04, E - 05 & E - 07 For Additional Technical Parameters Of Product / Work Refer Annexure A Attached. , On Board , Short Point (Up To 3 Mtr.) , Medium Point (Up To 6 Mtr.) , S&F Following Sizes (Dia.) Of Isi Marked Virgin Material Mms ( Is:9537 P - Iii ) Pvc Conduit Along With Isi Marked (Is:3419-1988) Accessories As Required In Recess Including Cutting The Wall, Covering Conduit And Making Good The Same As Required. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached . , 25 Mm , 32 Mm , Supplying And Drawing Fr Pvc Insulated & Unsheathed Flexible Copper Conductor As Per Pwd Specification For Electrical Works With Isi Marked (Is:694) And As Per Is 8130 : 2013 Of 1.1 Kv Grade . Wire Should Be Made From 99.90 % Purity Copper, Class 5 Stranding In Acc. To Is:8130/Iec 60228 For Lower Watt Loss , Oxygen Free For Less Chances Of Oxidization, Insulation Pvc Type A/C/D , Flame Retardant As Per Is 10810-53, Better Amperage Rating As Per Is:3961 Part 5, In Existing Surface Or Recessed Pvc/ Ms Conduit/Casing Capping Making Connections With Copper Lugs Of Suitable Size, Ferrules,Testing Etc. As Required. Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Wires. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached . , 2X 1.5 Sq.Mm , 2 X 2.5 Sq. Mm. + 1X1.5Sqmm , 2 X 4.0 Sq. Mm. + 1 X 2.5 Sq. Mm. , 4 X 10.0 Sq.Mm , 4 X 16.0 Sq.Mm , Supplying And Fixing Of Power Plug Point With Modular Accessories As Per Pwd Specification For Electrical Works, On Hot Dipped Galvanized Modular Box Of 1.2 Mm Thick With Earthing Terminal/Connector On Surface Or In Recessed With Suitable Size Of Modular Face Place With Grid Plate And Cover Plate Including Cost Of Isi Marked Modular 16 Amp. Switch (Is :3854) And 6/16 Amp. Socket Outlet (Is:1293) Making Connection , Testing , Etc. As Required. For Specification Of Wiring Accessories Refer Chapter E - 07 Related Item & For Additional Technical Parameters Of Product / Work Refer Annexure A Attached . , Providing & Fixing Of Wiring Accessories Oem Fabricated Following Size Gi Box Of 1.2 Mm Thick With Earthing Terminal And Adjustable Floating Clamp In Recess/ Surface Suitable For Modular Accessories As Required.All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached . , 1/2 Module , Providing & Fixing Of Following Size Mounting Grid Plates With Cover Plates Made From Fire Retardent Uv Established High Performance Engineering Plastic Suitable For All Universal Metal Boxes For Front Installation & Removal Direct Fit Type Complete In All Respect.All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached . , 1-2 Module , Providing & Fixing Of 240/415 V Ac Mcb With Positive Isolation Of 10 Ka Breaking Capacity (B/ C/D Tripping Characteristic As Per Type Of Load And Site Requirement) 4 Kv Impulse Withstand Voltage, Isi Marked Is 8828(1996) / Conforming To Iec 60898-1 2002, Iec 60947-2, Low Watt Losses, Trip Free Mechanisum , Energy Limiting Of Class 3 As Per Iec, Minimum Phase Termination Capacity Of 35Sq.Mm. , Conductor Line Load Reversibility , Ip 20 Contact Protection And Fitted In Existing Distribution Board/Sheets, Minimum Electrical Operation 20,000 Upto 20 A Rating And 10,000 Upto 63 A, 5000 For 80 A & Above Rating Including Making Connections, Testing Etc. As Required. Oem Shall Have Submit Nabl / Cpri / Erda Accrediated Lab Type Test Reports & All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached. , Single Pole Mcb (With B/C Curve Tripping Characteristics) , 6 A To 32 A Rating , Providing & Fixing Of Recessed/Surface Mounting Heavy Duty Horizontal Type Double Door ( Metal / Glazed )Distribution Board With Metal End Box Made Out From Galvanized Steel / Crca Sheet Not Less Then 1.2 Mm Thick Conforming To Is-8623-1 & 3 / Iec 61439- 1 & 3, Powder Painted Complete With Reversible Door (For Double Door Db Only )100 Amp. Insulated Copper Bus Bar/Shorting Link , Copper Neutral Link, Copper Earth Link , Color Coded Interconnecting Wire Set Of Suitable Rating And Din Bar,Masking Sheet, Making Internal Db Terminations With Copper Lugs, Ferrules, Detachable Gland Plate, Including Making Connections, Testing Etc. As Required. Oem Shall Have Submit Nabl / Cpri / Erda Accrediated Lab Type Test Reports & All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached . , Metal Door (Three Phase) Ik-09 And Ip-43 With Metal End Box , 6 Way , Providing & Fixing Of Recessed/Surface Mounting Heavy Duty Vertical Tpn Distribution Board With Metal End Box With Provision Of Incomer Suitable For Mcb / Rccb And Sp / Tp Mcb As Outgoing ,Made Out From Galvanized Steel / Crca Sheet Not Less Then 1.2 Mm Thick Conforming To Is-8623-1 & 3 / Iec 61439- 1 & 3. Powder Painted With Reversible Door (For Double Door Db Only ) Complete With Insulated 100 A Rating Copper Bus Bar, Neutral Bars With Shrouds, Earth Bar , Color Coded Interconnecting Wire Set Of Suitable Rating And Din Bar,Masking Sheet, Making Internal Db Terminations With Copper Lugs, Ferrules, Detachable Gland Plate, Including Making Connections, Testing Etc. As Required. Oem Shall Have Submit Nabl / Cpri / Erda Accrediated Lab Type Test Reports & All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Product / Work Refer Annexure A Attached . , Double Door Ik-09 & Ip-43 With Metal End Box , 6 Way(8+18) , Providing & Fixing Of 240/415 V Isolator Isi Marked Is:13947-Iii/Conforming To Iec 60947-3, Suitable For Ac22a Utilization Category, 4Kv Impulse Withstand Voltage, True Contact Indication, Red Colour Dolly / Lever Shall Have Single Mould Covering Over All Poles For Operation , Two Position Din Rail Mounting, Minimum Phase Termination Capacity Of 35Sq.Mm. Ip 20 Contact Protection And Fitted In Existing Distribution Board / Sheet Including Making Connections, Testing Etc. As Required. Oem Shall Have Submit Nabl / Cpri / Erda Accrediated Lab Type Test Reports & All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Product / Work Refer Annexure A Attached . , Four Pole Isolator , 80 A/ 100 A Rating , Triple Pole Isolator , 63A Rating , Providing & Fixing Of Following Modular Accessories As Per Pwd Specification For Electrical Works, Made Out Of Unbreakable And Fire Retardant Vergin Poly Carbonate With Brass Terminals And Captive Screws & Silver Alloy Contact Tip With Ip-20 Rating , Including All As Per Pre Approved By Engineer In Charge,Making Connections, Testing Etc. As Required. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached . , 25 Amp. 2 Module Motor Starter With On / Off Push Button , Blanking Plate , Providing & Fixing Of Modular Type 120 W Step Fan Regulator Duly Isi Marked (Is 11037:1984 ) With Cm/L No. Printed Made Out Of Unbreakable And Fire Retardant Vergin Poly Carbonate With Brass Terminals And Captive Screws & Silver Alloy Contact Tip With Ip-20 Rating , Including All As Per Pre Approved By Engineer In Charge,Making Connections, Testing Etc. As Required. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached . , 5 Step Fan Regulator 2 Module 360 Dgree Rotating , Providing & Fixing Of Modular Type Switch/ Bell Push Duly Isi Marked (Is :3854) With Cm/L No. Printed And Made Out Of Unbreakable And Fire Retardant Vergin Uv Stabilized Polycarbonate With Brass Terminals And Captive Screws & Silver Alloy Contact Tip With Ip-20 Rating ,Minimum Width Of Switch Toggle( Push Part ) Should Not Less Then 20Mm, Including All As Per Pre Approved By Engineer In Charge,Making Connections, Testing Etc. As Required. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached . , 10 A Bell Push , Providing & Fixing Of Ding Dong/Musical Chime Bell As Per Pwd Specification For Electrical Works, Including Making Connection Testing Etc. As Required.All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached . , Supply Installation Testing and Commissioning of 3 /4 Pole Current Limiting Moulded Case Circuit Breaker (Mccb) Made Of Flame Retardent & Heat Resistant Material Having Following Current Rating, Short Circuit Breaking Capacity At 440/415 V, 50 Hz; O/L & S/C Settings , Conforming To Is/Iec 60947 P -2 :2003 With Front Face And Centralised Adjustable, Trip Free Mechanisum, True Contact Position Indicator, Line Load Interchangeability, Designed For Both Horizontal & Vertical Mounting Without Any Adverse Effect On Electrical Performance, Suitable For Operation Upto 55 Degree And Without Derating Upto 40 Degree, Pollution Degree 3, Having Positive Isolation Capability, Push (Test) To Trip, Trip Time Less Then 10 Ms Under S/C Condition, Breaking Capacity Ics = 100% Icu. U Improvement =8 Kv, Rated Insulation Voltage 690 V. Provision For Uvr , Shunt Trip , Earth Fault Trip, Door Interlock, Pad Lock & Rotary Handle , Including Making Connections Etc. As Required.Oem Shall Have Submit Nabl / Cpri / Erda Accrediated Lab Type Test Certificate Before Execution All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached. , 3 Pole Mccb With Thermal Magnetic Release , Up To 100 annual periodical maintenance , 25 Ka, Adjustable O/L & Adjustable S/C Setting, , Providing & Laying P.V.C. / Xlpe Insulated & P.V.C. Sheathed Arrmoured Aluminium Cable Confirming To Is:1554 P-I / Is :7098 P - I Of 1.1 Kv With H4- Grade Electrolytic Aluminium Conductor Confirming To Is 8130 Of Purity 99.6 %, Round / Flat Strip Armouring Of Cables, Inner / Outer Sheath Confirming To Is:5831 In Existing Reinforced Cement Concrete / Hume / Stoneware / Pvc Pipe/ Open Duct/Cable Trench / Cable Tray(With Cable Tie) Including Testing Etc. As Required Of Following Size. Oem Must Have Its Own In House Nabl Accrediated Laboratory For Testing Procedure As Per Is:10810.For Additional Technical Parameters Of Product / Work Refer Annexure A Attached . , 35.0 Sq. Mm , 3.5 Core , Add Extra For Laying Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Direct In Ground Including Excavation Of Trench Of Size 75 Cm (Depth) X 35 Cm(Width) , With Procedure As Per Following Points:- (A) Make A River Sand Bed Of Height 125 Mm Along The Trench, (B) Lay The Cable In The Middle Of The Trench, (C) Provide River Sand Bed Of Height 125 Mm On Top Of The Cable, (D) Lay The Protective Common Burnt Clay F.P.S. Bricks Of Class Designation 75 / Sand Stone Slabs Of 50 Mm Thickness And 225 Mm Wide Just Above The Sand Bed Vertically Across The Cable ( Approx. 9 No. Bricks Per Mtr.), (E) Backfill The Excavated Soil Leaving 300 Mm From The Ground Level, (F)Lay The Cable Warning Tape And Again Back-Fill The Remaining Portion Of The Trench Upto The Ground Level And Compacting The Earth , Supplying And Making End Termination With Heavy Aluminium Lugs ( Pin / Ring Type ) Confirming To Is 8309 -1993 & Is 8337-1976 Duly Crimped With Crimping Tool, Pvc Tape Etc Of Following Size.All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached . , 35.0 Sq.Mm , P / L Of Double Wall Corrugated Hdpe Pipe Confirming To Is : 16205 P-24, Stiffness Class 750 N, Externally Corrugated And Having Smooth Surface Inside With Hdpe Coupler, Elbow, Tee At Required Depth Below The Ground For Laying Cable Of Following Nominal Outer Dia. Mfr Test Report From Nabl Accrediated Is To Be Submitted.(Excavation Of Earth & Back Filling With Compaction Is To Be Paid Extra)All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached . , 50 Mm , Labour Charges For Excavating Trenches Of Required Width For Pipes Dressing Of Sides, Ramming Of Bottoms, Depth Up To 1.5 Mtr. Including Taking Out The Excavated Soil, And Then Returning The Soil As Required In Layers Not Exceeding 20Cm In Depth Including Consolidating Each Deposited Layer By Ramming, Watering Etc. And Disposal Of Surplus Excavated Soil As Directed Within A Lead Of 50 Mtr.: , All Kind Of Soils , Providing & Fixing Of Bee Star Rated Copper Wounded Double Ball Bearing Capacitor Start, Aluminium Body & Metallic Blade Ceiling Fan Conforming To All The Performance Requirements Laid Down In Is 374:2019 Including All Amendments, As Applicable ; & Carry Bis Licensing (I.E. Isi Marking) With Down Rod Up To 80 Cm With Secondary Support Safety Cable ( Steel Rope) , Cotter Pin With 3 X 1.5 Sq.Mm Pvc Insulated Flexible Copper Conductor Making Connection Testing Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached . , 1200 Mm Sweep Bee 1 Star Rated (Service Value =4.0 To 4.5 ) , P & F 1.2Mm Thick M.S. Recessed Fan Box, Hexagonal/ Round Of Size 130 Mm Dia, Depth 75Mm, 12 Mm Dia Rod Fan Hook With 100 Mm Length Extended On Each Side . All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached. , Providing & Fixing Of Of Double Ball Bearing, Copper Wounded Capacitor Start Single Phase Metallic Blade Fresh Air Fan, In Existing Opening Including Cost Of Hardware , Flexible 3 Core Copper Conductor ,Making Connections, Testing Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached . , 300 Mm Sweep , P & F Of Gravity Louver Shutter Of Superior Quality Made Out Of Frame Of 18 Swg M.S. Sheet & Louvers Made From 24 Swg Ms Sheet With Enamel Paint Including Cost Of Nuts, Bolts, Etc As Reqd. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached . , Up To 380 Mm Size , Providing & Fixing Of Energy Efficient Direct Fit (Retrofit) Polycarbonate/ Glass Housing Smd Mid Power Led Tube Rod (With Integral Driver & Alumn. Heat Sink ), On Existing Fixture. System Lumen Efficacy ≥ 100 Lm/Watt Output, Internal Surge Protection Of 2.5 Kv ,Thd 20% ,P.F.≥0.95,Cri 80 , Life Time Of Minimum 35000 Burning Hours With , 70% Of Intial Lumen Maintaned Till Life Ends , Cct 3000°K / 4000°K / 5700°K /6000°K/6500°K (As Per Ansi Bin) , Maximum Power Consumption Should Not More Than The Specified Rating And Fixture Shall Be Of Bis Standard And Trade Mark Certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen Printing On Housing. Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Led Fixtures. (Lm79 & Lm80)Certificate / Report From Oem Shall Be Submitted. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached . , 1200Mm , Min. Lumens Output 2000 Lm Led Tube Rod With Polycarbonate Housing , Providing & Fixing Of Ip20, 2X2 Led Surface/ Recessed Mounting Mid Power Smd Type Led Light Fixture Not Less Than 50Mm Housing Depth Made From Crca Sheet Steel Housing, High Purity / Transmisivity Uv Stabilized Non -Yellowish Diffuser For Uniform Light Distribution. High Efficiency With 4 Kv Internal/External Surge Protection Bis Certified Isolated Driver Having Efficiency 85% , With Short & Open Circuit Protection (Integral With Light Fixture). System Lumen Efficacy Of ≥ 120 Lm/Watt ,Thd 10 % , P.F.≥0.95,Cri 80 , Life Time Of Minimum 50000 Burning Hours With , 70% Of Intial Lumen Maintaned Till Life Ends , Cct 3000°K / 4000°K / 5700°K /6000°K/6500°K (As Per Ansi Bin) , Maximum Power Consumption Should Not More Than The Specified Rating And Fixture Shall Be Of Bis Standard And Trade Mark Certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen Printing On Housing. , Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Led Fixtures. (Lm79 & Lm80) Certificate / Report From Oem Shall Be Submitted. All As Per Pre Approved By Engineer In Charge. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached . , Surface Moutning , Minimum Lumen Output 3600 Lm , Providing & Fixing Of Ip-20 Led Recessed / Surface Mounted, Round / Sqaure Smd Mid Power Led Downlight With Power Coated Die-Cast Aluminum Housing With Uv Stabilized Non Yellowish Diffuser With Bis Complience 2.5 Kv Surge Protected Isolated Driver, With Short & Open Circuit Protection, Having Efficiency 85% . System Lumen Efficacy Of ≥ 110 Lm / Watt, Thd 10 % , Pf.≥0.95, Cri 80, Life Time Of Minimum 50000 Burning Hours With , 70% Of Intial Lumen Maintaned Till Life Ends , Cct 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As Per Ansi Bin) , Maximum Power Consumption Should Not More Than The Specified Rating And Fixture Shall Be Of Bis Standard And Trade Mark Certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen Printing On Housing. , Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Led Fixtures. (Lm79 & Lm80) Certificate / Report From Oem Shall Be Submitted. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached . , Surface Mounting (With Extruded Alumn. Housing ) , Minimum Lumen Output 1300 Lm , Minimum Lumen Output 1950 Lm , Plate Earthing As Per Is:3043 With Hot Dipped G.I. Earth Plate Of Size 600Mm X 600Mm X 6.0Mm By Embodying 3 To 4 Mtr. Below The Ground Level With 20 Mm Dia. G.I. B Class Watering Pipe ,Including All Accessories Like Nut, Bolts, Reducer, Nipple, Wire Meshed Funnel, And Heavy Duty Weather Proof Poly-Propylene Earth Pit Chamber With Lockable Jam Free Lid Suitable For Safe Working Load 5000 Kg Or More Of Size Top Dia. 225 To 260 Mm, Bottom Dia 300 To 350 Mm. And Height 250 To 300 Mm. And Embodying The Pipe Complete With Alternate Layers Salt And Coke/ Charcoal, Testing Of Earth Resistance For Value Of 5 Ohms Or Less As Required & Must Record By Engineer In Charge During Site Visit And Ensure To Enter In Measurment Book.All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached . , Supply & Laying Following Size Earth Wire In Horizontal Or Vertical Run In Ground/Surface/Recess Including Riveting, Soldering, Saddles, Making Connection With Gi/Cu Purity Purity 95% Thimble Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached. , 8 Swg G.I. ( Hot Dipped ) Wire , Providing & Fixing Of Ik08, Ip 66 Protected Led Street Light Luminaire On Existing Bracket/Pole. Fixture Made Of Powder Coated Single Piece Pressure Die Cast Aluminum Material With Heat Dissipation Fins On Housing With Uv Stabilized Pc (Uv Stablization Report Submitted For Uv Cover ) /Toughened Glass Cover And Secondary Lens On Each Led & Should Be Smd Type Of 3 To 5 Watt Each . The System Efficacy =125 Lm/ Wt And Potted Driver & Has A Unique Bis R Number With Input Voltage Ac 120 To 270 V Ac With High Voltage Cutoff @=300 V Ac And Auto Resetting Safety , Power Factor 0.95 Driver Efficiency 85% ,Thd(I) 10% Humidity 10% To 90% Rh Working Temp -5C To 45C . Driver Current 750Ma. The Luminaire Shall Be Bis Certified And Trade Mark Certified. Life Expectancy Equal Or More Than 50000 Burning Hrs With Minimum 70% Lumen Maintened , Cri 70 And Cct 5700K +355K. Surge Protection Shall Be Min ≥ 4 Kv Internal And Min 10 Kv External Inside Driver Compartment. Driver Should Be Phase To Phase Protection Of 440 V For 4 Hrs. Manufactures Word Mark/Name Engraved/Embossing On Die Cast Housing To Allow Traceability/Authenticity. Fixture Shall Be As Per Is 10322 Complianced.Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Led Fixtures. (Lm79/Lm80) Certificate/ Report With Liable Warranty Of Product/Accessories From Oem Shall Be Submitted. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached . , Led Street Light Fixture With Minimum Lumen Output 12500 Lm , Providing & Fixing Of Street Light Bracket Made Out From Following Size Of B Class , Medium Class G.I. Pipe Confirming To Is : 1239 P - 1 ( 2004 ) With Heavy Duty Pole Clamp, Saddles Suitable Fastners Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached . , 32 Mm Dia. , Supply Installation Testing and Commissioning of Mnre Approved & Confirming To Is:12933 P-1,2,3 & 5 Flat Plate Collector Type Solar Hot Water System Having Collector With Zincalum Sheet Outer Body , Glass - Line / Titanium Enamel Coated Inner Tank With Metal Rust Proof Puf Insulated Body Including Electrical Back Up, Thermostat, Powder Coated / Hot Dipped Galvanized Ms Stand For Collector & Tank Etc. As Required. Of Following Capacity Complete In All Respect. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached . , 250 Litre/ Day , Supply , Installation, Testing And Comissioning Of Is:1475 Marked Self Contained Drinking Water Cooler With Hermetically Sealed Compressor,Non Cfc Refrigerent Suitable For Operation On 230V/1Ph/50Hz Ac Supply,Full Stainless Steel (Ss304)Body (0.8 Mm Thick) And Tank (0.5 Mm Thick) , Stainless Steel Water Tray,Minimum Two Nos Brass Chrome Plated Faucets And Suitable Drainage System Complete In All Respect With Required Height Ms Fabricated And Painted Angle Iron Frame ( Cost Of Frame To Be Paid Extra )Complete In All Respect Of The Following Capacity. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached . , Cooling Capacity 150 Ltr./Hr. And Storage Capacity 150 Ltrs , Supply, Fixing And Testing Of Following Capacity Iso Certified Company Made Wall Mounted Stabilizer Having Output Voltage Variation From 200 V To 250 V(+/-5%) With Input Voltage Variation From 170 V To 260 V, Time Delay Facility From 2 To 4 Minute And High Cutoff At 270 V With Providing Of 16 annual periodical maintenance /20 annual periodical maintenance Industrial Plug Top Making Connection Etc Complete In All Respect. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached . , 4 Kva , Making Hole In Stone Masonary/ Reinforced Cement Concrete Wall/ Reinforced Cement Concrete Slab With Core Cutter For Accomodating Refrigerant Pipe/ Drain Pipe/ Ms Pipe/ Cables Etc Of Following Dia , 50 Mm Dia Per Running Inch Length , Supply , Installation, Testing And Comissioning Of Inverter Type Air Cooled Hi Wall Split Type Air Conditioners With Latest Star Rating System As Per Bee Amended Upto Date Complete With Indoor Unit(Idu), Out Door Unit (Odu), Surface / Concealed Copper Refrigerant Piping With Insulation (Closed Cell Elastomeric Nitrile Rubber Tubular Pipe Section) Upto 3 Mtr (Idu To Odu), Copper Power Cable Upto 3.5 Mtr (Idu To Odu), R-32/R-410 Green Refrigerant, Wireless Remote Control, Suitable For Working Between 230V +/- 10% With Low & High Voltage Cutoff And 50 Hz , Single Phase Ac Supply Capable Of Performing Cooling, Dehumidification, Air Circulation Of Following Capacity With Scroll / Rotary Compressor. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached . , 1.5 Tr Iseer Not Less Then 3.8 , Supply Installation Testing and Commissioning of Monoblock Motor Pump Set Isi Marked (Is:9079-2002) With Tefc Motor, Motor Should Be Ie2 Class As Per Iec 60034-2-1: 2007, Iec 60034-30: 2008, & Is12615:2011. With Stainless Steel Impellor, Stainless Steel Shaft, Mechanical Seal, Single/Three Phase ( 240 - 440 V ) Permanent Split Capacitor Type (Psc), Fitted With Thermal Overload Protection, Including Cost Of Hardware Etc On Existing Platform Complete. Pump Shall Have Following Hp Rating, Phase, Head, Minimum Discharge Respectively Complete In All Respect. Oem Shall Have Submit Nabl / Cpri / Erda Accrediated Lab Type Test Certificate Before Execution. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached . , 2.0 Hp, 3-Ø, (6-27)Mtr, (425-100) Lpm , Supply Installation Testing and Commissioning of Contactor Oem Fabricated Dol/Star-Delta Starter Panel With Switchgear Selection As Per Type-2 Cordinatiom Chart And Made Out From 1.6 Mm Thick Powder Coated Crca Sheet, Enclosure Comprising Of Over Load Protection Relay, Short Circuit & Single Phasing Protection, Illuminated On / Off Push Buttons, Ammeter, Voltmeter, Indicating Lamps Etc. Suitable For Following Rating Motors Complete In All Respect. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached . , For Single Phase Submersible / Monoblock Pump , 2.0 Hp To 3.0 Hp (Dol Starter)
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 3
8.
Tourism #10977010 AOC
Tender for Cables, Earthings , Supply Of 4 Core Unarmoured Pvc/Xlpe Insulated, Pvc Sheathed Copper Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size.4 Core 1.5 Sq.Mm , Supply Of 4 Core Armoured Pvc/Xlpe Insulated, Pvc Sheathed Aluminium Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 4 Core 10 Sq.Mm , Supply Of 4 Core Armoured Pvc/Xlpe Insulated, Pvc Sheathed Aluminium Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 4 Core 25 Sq.Mm , Laying Of One Number Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Size Not Exceeding 25 Sq.Mm Direct In Ground Including Excavation In The Form Of A Trench As Per Cable Trench Drawing Provided By The Engineer-Incharge,Sand Cushioning With Screened Sand Bed Of 20Mm Thick , Protective Covering With Bricks Placed Breadth-Wise On Top Of Cable All Over The Run( The Brick Protection Shall Cover The Cable And Project Atleast 5 Cms Over The Sides Of The Cable) And Backfilling The Excavated Earth Without Stones Or Hard Material And Making The Surface Proper With 15 Cm Crown On The Top Complete As Required.(A) In Soily Strata , Supply Of 3 Core Unarmoured Pvc/Xlpe Insulated, Pvc Sheathed Copper Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 3 Core 1.5 Sq.Mm , Supply Of 3 Core Unarmoured Pvc/Xlpe Insulated, Pvc Sheathed Copper Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 3 Core 2.5 Sq.Mm , Laying Of One Number Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Size Not Exceeding 25 Sq.Mm On Surface, Etc. Complete As Required , Earthing With Gi Earth Pipe 2 Mts Long 40 Mm Dia Medium Class With Isi Mark,Of Approved Brands, Including Accessories And Providing Masonry Enclosure With Ci/Rcc Cover Having Locking /Lifting Arrangement And Watering Pipe Etc. With Charcoal Or Coke And Salt) As Required As Per The Earthing Drawing Provided By The Engineer-Incharge.The Scope Of Work Includes The Following: A) Excavation Of Pit Of Size 1.0X1.0X 2.0 Mtrs(Min) And Disposal Of Excavated Soil. B) Class B Gi Pipe, 40Mm Diameter As Per Specifications. C) Charcoal/Salt As Per Specs ( Paid Seperately). D) Refilling The Pit Of Size 1.0X1.0X 2.0 Mtrs(Min) With Soft Black Soil Of Minimum Resistivity I/C Transportation. E)Masonary Chamber With Proper Foundation, Cover Plate And Locking Arrangement. F) Testing Of Earth Value With Earth Megger And Certifications Of Its Value. Aluminium Tag With Embossed Earthing Value To Be Attached To The Pipe. G)Watering Arrangement(Plumbing Will Be Paid Seperately).(A) In Soily Strata , Extra For Using Salt And Charcoal For Pipe Earth Electrode As Required( 65 Kgs Of Charcoal And 5 Kgs Of Salt). , Supplying And Laying 25 Mm X 5 Mm Gi Strip In 40 Mm Dia Gi Pipe From Earth Electrode As Required , Supplying, Of Hdpe Pipes At Store Or Site Of Work Including Loading, Unloading, Stacking, Transit Insurance Etc. Complete Bearing Isi Mark &Conforming To Is: 4984-1995 & Made From Pe 100 Resin Class Iv (6 Kg/Cm2). Outer Dia. 90 In Mm , Foundations , Earthwork In Excavation By Mechanical Means (Hydraulic Excavator)/Manual Means In Foundation Pipeline Trenches Drain (Not Exceeding 1.5 M In Width Or 10 Sq.M. On Plan) Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soil As Directed Within A Lead Of 50 M. A) All Kinds Of Soil , Rubble Packing With Hard Laterite Stone Under Floors Including Watering Ramming And Consolidating Etc. In Pipeline Trenches And Other Foundations Complete. , Providing And Laying In Position Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand: 4 Graded Granitic Or Basaltic Stone Aggregate 40 M Nominal Size) Excluding Cost Of Centering, Shuttering And Finishing. All Works Upto Plinth Level , Centering & Shuttering Including Strutting, Propping & Removal Of Forms For :Foundations, Footings, Bases For Columns , Providing And Laying In Position Ready Mixed Concrete (Rmc) With Usage Of Ordinary Portland Cement Manufactured In Fully Automatic Batching Plant And Transported To Site Of Work In Transit Mixer For A Lead Upto 10Kms Having Continuous Agitated Mixer, Manufactured As Per Mix Design Of Specified Grade For Reinforced Cement Concrete Work Including Pumping Of R.M.C., From The Transit Mixer To The Site Of Laying, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement Including The Cost Of Admixtures In Recommended Porportions As Per Is : 9103 To Accelerate/Retard Setting Of Concrete, Improve Workability Without Imparing Strength And Durability As Per The Directions Of The Engineer-In-Charge. All Works Upto Floor V Levelm-20 Grade Of Concrete , Providing And Laying In Position Ready Mixed Concrete (Rmc) With Usage Of Ordinary Portland Cement Manufactured In Fully Automatic Batching Plant And Transported To Site Of Work In Transit Mixer For A Lead Upto 10Kms Having Continuous Agitated Mixer, Manufactured As Per Mix Design Of Specified Grade For Reinforced Cement Concrete Work Including Pumping Of R.M.C., From The Transit Mixer To The Site Of Laying, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement Including The Cost Of Admixtures In Recommended Porportions As Per Is : 9103 To Accelerate/Retard Setting Of Concrete, Improve Workability Without Imparing Strength And Durability As Per The Directions Of The Engineer-In-Charge. All Works Upto Floor V Levelm-25 Grade Of Concrete , Providing And Laying In Position Ready Mixed Concrete (Rmc) With Usage Of Ordinary Portland Cement Manufactured In Fully Automatic Batching Plant And Transported To Site Of Work In Transit Mixer For A Lead Upto 10Kms Having Continuous Agitated Mixer, Manufactured As Per Mix Design Of Specified Grade For Reinforced Cement Concrete Work Including Pumping Of R.M.C., From The Transit Mixer To The Site Of Laying, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement Including The Cost Of Admixtures In Recommended Porportions As Per Is : 9103 To Accelerate/Retard Setting Of Concrete, Improve Workability Without Imparing Strength And Durability As Per The Directions Of The Engineer-In-Charge. All Works Upto Floor V Levelm-30 Grade Of Concrete , Providing Tmt Steel Reinforcement Bars Of (Sail, Tata. Vizag, Jsw Steel Ltd.) ) (Confirming To Is 1786 Of 1986) For Reinforced Cement Concrete Work (Conforming To I.S. 1786 Of 1986) Including Bending, Binding & Placing In Position In All The Floors Along With The Factory Made Precast Concrete Cover Blocks Of Specified Sizes Whose Compressive Strength Is Not Less Than That Of Surrounding Concrete In The Structural Member. , Dbs, Mcbs, Terminations, Wiring/Lights , Supplying And Fixing Following Way Tpn Sheet Steel, Single Door, Verticle Type Mcb Distribution Board 415 V On Surface/ Recess Complete With Tinned Copper Busbar Neutral Busbar Earth Bar Dinnbar Detachable Gland Plate Interconnections Phosphotized And Powder Painted Including Earthing Etc. As Required ( But Without Mcb/Rccb/Isolator)Interconnection Between Incomer Mccb And Busbars Of Following Ways (But Without Mcbs As Required)(A) 4 Way (8+12), Single Door, Vertical Type, Cat A , Providing & Fixing G.I. Pipes Complete With G.I. Fittings & Clamps, Including Cutting And Making Good The Walls Etc. (Internal Work)25 Mm Nominal Bore , Supplying And Fixing 6 A To 32 A, C Series Mcb Suitable For Lighting And Other Loads Of Following Poles In The Existing Mcb Db Complete With Connections Testing And Commissioning Etc As Required.(A) Sp, Cat A , Supplying And Fixing 6 A To 32 A, C Series Mcb Suitable For Lighting And Other Loads Of Following Poles In The Existing Mcb Db Complete With Connections Testing And Commissioning Etc As Required.(E) Tpn, Cat A , Supplying And Making Cable End Terminations With Brass Compression Gland And Copper Lugs For Folowing Sizes Of 4 Core Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade, Complete As Required.(4) 4 X 10 Sq. Mm. , Wiring For Group Controlled Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable (With)In Recessed Pvc Conduit(Medium) And Earthing The Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate And Switch Box Including Connections But Excluding Modular Plate Etc. As Required (A) 5/6 A Switch Cat A , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate And Switch Box Including Connections But Excluding Modular Plate Etc. As Required (D) 3 Pin 5/6 A Socket Outlet Cat A , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate And Switch Box Including Connections But Excluding Modular Plate Etc. As Required B) 15/16 A Switch Cat A , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate And Switch Box Including Connections But Excluding Modular Plate Etc. As Required D) 6 Pin 15/16 A Socket Outlet Cat A , Supply And Erecting Of 48 Inch (1200Mm Sweep) Ceiling Fan, Double Ball Bearing Type, , Complete With All Accessories. , Supplying And Fixing Stepped Type Electronic Fan Regulator On The Existing Modular Plate Switch Box Including Connections But Excluding Modular Plate Etc. As Required , Supply And Erecting Fan Hook Box ( 100 Mm Diameter Or Equivalent Square Size, 75Mm Deep) Fabricated Out Of 16 Swg Sheet Steel With 10 M Round Bar Hook Bounded To Reinforced Cement Concrete Steel Upto 50 Mm Length Protruding On Each Side Of The Box, Including Painting With 2 Coats Of Red Oxide, Complete As Required. , Supplying & Erecting Led 20W Tube Light Fitting (4 Feet), 5700K, With Crca Housing, Heat Sink, With Industrial Grade Heavy Duty Driver Complete Havels Cat Stout Mini 1200Bs 40W Led 865 Make Philips / Wipro Cat No Ll24-541-Xxx-57-Cd (Including Lamp) , Supply, Installation , Testing And Commissioning Of 12W Uplighter Including Driver Of Ip 66 As Required As Directed By The Engineer Incharge Of Colour Output: Warm White Of Make: Atilite, Wipro, Transrail, Bmp. , Supply, Installation , Testing And Commissioning Of 15W Uplighter Including Driver Of Ip 66 As Required As Directed By The Engineer Incharge Of Colour Output: Warm White Of Make: Atilite, Wipro, Transrail, Bmp. , Supply, Installation , Testing And Commissioning Of Wall Washer Of 36W Including Driver Of Ip 66 As Required As Directed By The Engineer Incharge Of Colour Output: White Of Make: Atilite, Wipro, Transrail, Bmp. , Supply, Installation , Testing And Commissioning Of Wall Washer Of 20W Including Driver Of Ip 66 As Required As Directed By The Engineer Incharge Of Colour Output: White Of Make: Atilite, Wipro, Transrail, Bmp. , Supply, Installation , Testing And Commissioning Of 2 Mtr Corner Profile Of Ip 66 As Required As Directed By The Engineer Incharge Of Colour Output: Warm White Make: Atilite, Wipro, Transrail, Bmp. , Supply, Installation , Testing And Commissioning Of 1 Mtr Corner Profile Of Ip 66 As Required As Directed By The Engineer Incharge Of Colour Output: Warm White Make: Atilite, Wipro, Transrail, Bmp. , Supply, Installation , Testing And Commissioning Of Decorative Wall Fixtures Of 50W Of Ip 66 As Required As Directed By The Engineer Incharge Of Colour Output: Whitemake: Atilite, Wipro, Transrail, Bmp. , Supply And Fixing Of Junction Box Of Model Dk 1000G Of Size 130X180x77 Hensel Box As Required As Directed By The Engineer Incharge , Supply And Fixing Of Junction Box Of Model Wp 0402G Of Size 104X104x70 Hensel Box As Required As Directed By The Engineer Incharge. , Supply And Laying Of 14 Swg Copper Wire , Supply And Laying Of 25Mm Rigid Pvc Pipe Hms , Supply, Installation , Testing And Commissioning Of Outdoor Stand Mounted Feeder Pillar Ip66 Rated With 32A Tpn Mcb Incomer, Single Dial Timer, 25A Cotactor For Automatic Switching Of Luminaries .Of Make L &T/Schneider/Havells /Legrand, Incoming 10 Sq.Mm And Outgoing 2.5Sq.Mm Terminals With Outgoing Mcbs 6 Nos. The Panel Should Be Cpri Approved As Required As Directed By The Engineer Incharge. , Supply And Installation Of Driver Of 150W Make Meanwell, Philips As Directed By The Engineer Incharge , Supply Installation Testing and Commissioning of Decorative 3Mtr Height Post Top Gi Pole Made Up Of Aluminium With Pure Polyster Power Coating. Pole Dia Of 60Mm With Base Plate Of 200Mmx200mm. Having Halo Ring Design Fixture Of 50W. Ip66. With Inbuild Driver Of Philips Make. Input Surge Protection: 6Kv. Power Factor: 0.90. Cri: 80. Operating Voltage: 80-240V Ac, 50-80Hz. Make: Transrail, Wipro, Bmp. , Supply, Fixing, Testing And Commissioning Of 350W Led Flood Light Luminiare Ip 66 Optic Compartment, Pressure Die Cast Aluminium Housing, Control Gear Compartment, Frame With Toughened Glass With Luminious Efficacy 115 Lumen/W At Ta 25 Deg C.In Built Surge Protection Upto 10Kv As Required And Directed By Engineer Incharge. Make Transrail,Wipro, Atilite. , Supply, Fixing, Testing And Commissioning Of 50W Led Flood Light Luminiare Ip 66 Optic Compartment, Pressure Die Cast Aluminium Housing, Control Gear Compartment, Frame With Toughened Glass With Luminious Efficacy 115 Lumen/W At Ta 25 Deg C.In Built Surge Protection Upto 10Kv As Required And Directed By Engineer Incharge. Make Transrail,Wipro, Atilite. , Supply, Installation, Testing And Commisioning Of 20 Mtr High Mast System With Head Frame, Galvanized Lantern Carriage. Mast Shaft Shall Be In Two Sections, Hot Dip Galvanized And Suitable For 44(Mtr/Sec) Wind Velocity As Per Is 875, The Mast Shall Have An Integral Powertool Installed Inside The Base Compartment For Its Operation. It Shall Include Accessories For High Mast Including Steel Wire Rope 6 Mm Dia(7/19 Construction ), Trailing Cable (5 Core 2.5 Sq.Mm), Double Drum Winch, Connector, Integral Power Tool Motor, Manual Handle For Lowering And Rasing Mechanism, Junction, Box Etc. Complete As Required And Directed By Engineer Incharge. Make :- Transrail, repair renovation Ispat, Vakrangee, Valmount. Make :- Transrail, repair renovation Ispat, Vakrangee, Valmount. , Supply, Installation, Testing And Commisioning Of 12.5 M High Mast With Head Frame, Mast Shaft Shall Be In Two Sections, Hot Dip Galvanized (Avg Microns On Hm Shall Be 100 Microns Taking Into Consideration Of Coastal Beach Line) Suitable For Wind Speed 44M/Sec Wind Velocity As Per Is 875,Galvanized Luminaries Carriage Suitable To Install 6-8 Nos.Luminaries (350 W Fixtures) In Symmetrical Arrangement, The Mast Shall Have An Integral Powertool Installed Inside The Base Compartment For Its Operation, Lightning Finial Along With The Other Accessories Like Double Drum Winch, 6 Mm Diameter Ss Wire Rope,Trailing Cable (5 Core 2.5 Sq.Mm),, Connector, Integral Power Tool Motor, Manual Handle For Lowering And Rasing Mechanism, Junction, Box Etc. Complete As Required And Directed By Engineer Incharge. Make :- Transrail, repair renovation Ispat, Vakrangee, Valmount. , Supply Of 9M High Mast Shaft In Single Sections Suitable For Wind Speed 47M/Sec. With Head Frame, Luminaries Carriage Suitable To Install Upto 6 Nos. Luminaries In Symmetrical Arrangement, Lightning Finial,Along With Supply Of Accessories Required Such As Double Drum Winch, 5Mm Diameter Ss Wire Rope, Trailing Cable, Connector, Integral Power Tool Motor, Manual Handle, Junction Box Etc. (Supply Of Bottom Mcbs, Top Junction Box, Top Distribution Cable For Light Fixture And Cables From Panel To The Base Of The Mast Shall Not Be In Our Scope) Make: Transrail, repair renovation Ispat, Vakrangee, Valmount. , Supply, Installation, Testing And Commisioning Of Foundation Bolts For 20Mtr High Mast Manufactured From Special Steel Along With Nuts, Washers, Anchor Plate And Suitable Template Complete As Required And Directed By Engineer Incharge. Make :- Transrail, repair renovation Ispat, Vakrangee, Valmount. , Supply, Installation, Testing And Commisioning Of Foundation Bolts For 9Mtr And 12.5Mtr High Mast Manufactured From Special Steel Along With Nuts, Washers, Anchor Plate And Suitable Template Complete As Required And Directed By Engineer Incharge. Make :- Transrail, repair renovation Ispat, Vakrangee, Valmount. , Supply, Installation, Testing And Commisioning Of Of Single Dome Aviation Obstruction Light Complete As Required And Directed By Engineer Incharge. Make :- Transrail, repair renovation Ispat, Vakrangee, Valmount. , Supply Installation Testing and Commissioning of Outdoor Stand Mounted Feeder Pillar With 32A Tpn Mcb Incomer, Single Dial Timer, 25A Cotactor For Automatic Switching Of Luminaries , Power Tool Control With 2 No. 9A Contactors And Raise Lower Push Button, Incoming 35 Sq.Mm And Outgoing 16 & 2.5Sq.Mm Terminals With Outgoing Mcbs 6/8 Nos. With Meter Provision.
Contract Date: May 15, 2026 Contract Value : 4.09 Crore
Government Departments No of Bidders 3
9.
Power #10907633 AOC
Construction Of New Test Lab Building At 33/11 Kv Sub Centre, Fatehabad And Other Related Civil Works. - Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by Engineer-in- Charge: (DSR 2.1) All kinds of soil (DSR 2.1.1) 2 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and for all lift, as directed by Engineer-in-charge. (DSR 2.6) All kinds of soil (DSR 2.6.1) 3 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.(DSR 2.8) All kinds of soil. (DSR 2.8.1) 4 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 and for all lift. (DSR )(DSR 2.25) 5 Excavating, supplying, stacking and filling of local earth (excluding royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in foundation trenches, plinth, sides of foundation etc. complete for all lift. NSI Based on(DSR 2.25(a)) 6 Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials. (DSR 2.26) All kinds of soil (DSR 2.26.1) 7 Surface dressing of the ground including removing vegetation and in-equalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m. (DSR 2.28) All kinds of soil (DSR 2.28.1) 8 Excavating holes more than 0.10 cum & upto 0.5 cum including getting out the excavated soil, then returning the soil as required in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering etc, disposing of surplus excavated soil, as directed within a lead of 50 m and lift upto 1.5 m. (DSR 2.3) All kinds of soil (DSR 2.30.1) 9 Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared. (DSR )(DSR 2.31) 10 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : (DSR 4.1) 1:1½:3 (1 Cement: 1½ coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) (DSR 4.1.2) 11 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : (DSR 4.1) 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) (DSR 4.1.3) 12 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : (DSR 4.1) 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) (DSR 4.1.8) 13 Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing: (DSR 4.2) 1:1½:3 (1 cement : 1½ coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). (DSR 4.2.2) 14 Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing: (DSR 4.2) 1:2:4 (1 Cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) (DSR 4.2.3) 15 Centering and shuttering including strutting, propping etc. and removal of form work for : (DSR 4.3) Foundations, footings, bases for columns (DSR 4.3.1) 16 Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 12.5mm nominal size derived from natural sources) (DSR ) (DSR 4.10) 17 Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturers specification. (DSR )(DSR 4.12) 18 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : (DSR 5.1) 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) (DSR 5.1.2) 19 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : (DSR 5.2) 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) (DSR 5.2.2) 20 Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). (DSR )(DSR 5.3) 21 Centering and shuttering including strutting, propping etc. and removal of form for (DSR 5.9) Suspended floors, roofs, landings, balconies and access platform (DSR 5.9.3) 22 Centering and shuttering including strutting, propping etc. and removal of form for (DSR 5.9) Shelves (Cast in situ) (DSR 5.9.4) 23 Centering and shuttering including strutting, propping etc. and removal of form for (DSR 5.9) Lintels, beams, plinth beams, girders, bressumers and cantilevers (DSR 5.9.5) 24 Centering and shuttering including strutting, propping etc. and removal of form for (DSR 5.9) Columns, Pillars, Piers, Abutments, Posts and Struts (DSR 5.9.6) 25 Centering and shuttering including strutting, propping etc. and removal of form for (DSR 5.9) Stairs, (excluding landings) except spiral-staircases (DSR 5.9.7) 26 Centering and shuttering including strutting, propping etc. and removal of form for (DSR 5.9) Small lintels not exceeding 1.5 m clear span, moulding as in cornices, window sills, string courses, bands, copings, bed plates, anchor blocks and the like (DSR 5.9.15) 27 Centering and shuttering including strutting, propping etc. and removal of form for (DSR 5.9) Edges of slabs and breaks in floors and walls 5.9.16 Under 20 cm wide (DSR 5.9.16.1) 28 Centering and shuttering including strutting, propping etc. and removal of form for (DSR 5.9) Weather shade, Chajjas, corbels etc., including edges (DSR 5.9.19) 29 Providing, hoisting and fixing above plinth level up to floor five level precast reinforced cement concrete work in string courses, bands, copings, bed plates, anchor blocks, plain window sills and the like, including the cost of required centering, shuttering but , excluding cost of reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). (DSR )(DSR 5.12) 30 Providing, hoisting and fixing up to floor five level precast reinforced cement concrete in small lintels not exceeding 1.5m clear span up to floor five level, including the cost of required centering, shuttering but , excluding the cost of reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). (DSR )(DSR 5.13) 31 Providing, transporting, hoisting and fixing above plinth level up to floor five level precast reinforced cement concrete in lintels, beams and bressumers, including setting in cement mortar 1:3 (1 cement : 3 coarse sand), cost of required centering and shuttering but , excluding the cost of reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) (DSR )(DSR 5.15) 32 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level & above plinth level. (DSR 5.22) Thermo-Mechanically Treated bars of grade Fe-500D or more. (DSR 5.22.6)/ (DSR 5.22A.6) 33 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: (DSR 6.1) Cement mortar 1:4 (1 cement : 4 coarse sand) (DSR 6.1.1) 34 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: (DSR 6.1) Cement mortar 1:6 (1 cement : 6 coarse sand) (DSR 6.1.2) 35 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : (DSR 6.4) Cement mortar 1:4 (1 cement : 4 coarse sand) (DSR 6.4.1) 36 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : (DSR 6.4) Cement mortar 1:6 (1 cement : 6 coarse sand) (DSR 6.4.2) 37 Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. (DSR 6.13) Cement mortar 1:4 (1 cement :4 coarse sand) (DSR 6.13.2) 38 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels. (DSR 8.2) Raj Nagar Plain white marble/ Udaipur green marble/ Zebra black marble 8.2.1 Area of slab upto 0.50 sqm (DSR 8.2.1.1) 39 (DSR 8.2) Raj Nagar Plain white marble/ Udaipur green marble/ Zebra black marble 8.2.1 Area of slab over 0.50 sqm (DSR 8.2.1.2) 40 Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. (DSR 8.3) Granite work (DSR 8.3.2) 41 Extra for fixing marble /granite stone, over and above corresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive, including cleaning etc. complete. (DSR )(DSR 8.4) 42 Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. (DSR )(DSR 8.5) 43 Mirror polishing on marble work/Granite work/stone work where ever required to give high gloss finish complete. (DSR )(DSR 8.6) 44 Stone work (machine cut edges) for wall lining etc. (veneer work) upto 10 metre height, backing filled with a grout of average 12 mm thick cement mortar 1:3 (1 cement : 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade : (To be secured to the backing and the sides by means of cramps and pins which shall be paid for separately) : (DSR 8.14) Red sand stone - exposed face fine dressed with rough backing. 8.14.1 30 mm thick (DSR 8.14.1.5) 45 Providing and fixing plywood 4 mm thick, one side decorative veneer conforming to IS: 1328 (type-1), for plain lining / cladding with necessary screws, including priming coat on unexposed surface with : (DSR 8.28) Decorative veneer facings of approved manufacture (DSR 8.28.1) 46 Providing and fixing skirting with Pre-laminated (one side decorative and other side balancing lamination) flat pressed 3 layer or graded particle board (medium density) Grade I, Type II, IS :12823 marked, with necessary fixing arrangements and screws, including drilling necessary holes for rawl plugs etc. and priming coat on unexposed surface complete : (DSR 8.3) 18 mm thick (DSR 8.30.1) 47 Providing and fixing skirting with Pre-laminated (one side decorative and other side balancing lamination) flat pressed 3 layer or graded particle board (medium density) Grade I, Type II, IS :12823 marked, with necessary fixing arrangements and screws, including drilling necessary holes for rawl plugs etc. and priming coat on unexposed surface complete : (DSR 8.3) 25 mm thick (DSR 8.30.2) 48 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. (DSR )(DSR 8.31) 49 Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately). (DSR 9.1) Sal wood (DSR 9.1.2) 50 Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows, fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note:- Butt hingesand necessary screwsshall be paid separately) (DSR 9.5) Second class teak wood 9.5.1 35 mm thick shutters (DSR 9.5.1.1) 51 Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows, fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note:- Butt hingesand necessary screwsshall be paid separately) (DSR 9.5) Second class teak wood 9.5.1 30 mm thick shutters (DSR 9.5.1.2) 52 Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick : (DSR 9.7) Second class teak wood (DSR 9.7.1) 53 Providing and fixing glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes (weight not less than 10 kg per sqm) fixing with ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws. (DSR 9.9) Second class teak wood 9.9.1 35 mm thick (DSR 9.9.1.1) 54 Providing and fixing glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes (weight not less than 10 kg per sqm) fixing with ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws. (DSR 9.9) Second class teak wood 9.9.1 30 mm thick (DSR 9.9.1.2) 55 Extra for providing heavy sheet float glass panes instead of ordinary float glass in glazed doors, windows and clerestory window shutters. (Area of opening for glass panes excluding portion inside rebate shall be measured) (DSR 9.11) 5.0 mm thick(weight not less than 12.50 kg per sqm) instead of 4 mm thick(weight not less than 10 kg per sqm). (DSR 9.11.1) 56 Extra for providing frosted glass panes 4 mm thick (weight not less than 10 kg per sqm) instead of ordinary float glass panes 4 mm thick(weight not less than 10 kg per sqm) in doors, windows and clerestory window shutters. (Area of opening for glass panes excluding portion inside rebate shall be measured). (DSR )(DSR 9.12) 57 Extra for providing ISI marked Stainless Steel butt hinges instead of M.S. pressed butt hinges bright finished of required size with necessary screws. (Shutter area to be measured). (DSR )(DSR 9.14) 58 Providing and fixing 25 mm thick shutters for cup board etc. : (DSR 9.16) Panelled or panelled & glazed shutters : 9.16.1 Second class teak wood including ISI marked nickel plated bright finished M.S. piano hinges with necessary screws (DSR 9.16.1.2) 59 Providing and fixing 25 mm thick shutters for cup board etc. : (DSR 9.16) Glazed shutters : 9.16.2 Second class teak wood including ISI marked nickel plated bright finished M.S. piano hinges with necessary screws (DSR 9.16.2.2) 60 Providing and fixing flat pressed three layer particle or gradedplain wood board medium density exterior grade (Grade I) FPT-I, conforming and markedto frame, backing or studding with screws etc. complete (Frames, backing or studding to be paid separately): (DSR 9.17) 12 mm thick (DSR 9.17.1) 61 Providing and fixing flat pressed three layer particle or gradedplain wood board medium density exterior grade (Grade I) FPT-I, conforming and markedto frame, backing or studding with screws etc. complete (Frames, backing or studding to be paid separately): (DSR 9.17) 18 mm thick (DSR 9.17.2) 62 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: (DSR 9.21) 30 mm thick including ISI marked Stainless Steel butt hinges with necessary screws (DSR 9.21.2) 63 Providing and fixing wooden moulded beading to door and window frames with iron screws, plugs and priming coat on unexposed surface etc. complete : (DSR 9.4) Kiln seasoned and chemically treated hollock wood 9.40.2 50x12 mm (DSR 9.40.2.1) 64 Providing and fixing nickel plated M.S. pipe curtain rods with nickel plated brackets : (DSR 9.47) 25 mm dia (heavy type) (DSR 9.47.2) 65 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. (DSR 9.48) Fixed to steel windows by welding (DSR 9.48.1) 66 Providing and fixing ISI marked IS:1341 oxidised M.S. pressed butt hinges with necessary screws etc. complete. (Copper oxidised as per IS 1378) (DSR 9.57) 125x65x2.12 mm (DSR 9.57.1) 67 Providing and fixing ISI marked IS:1341 oxidised M.S. pressed butt hinges with necessary screws etc. complete. (Copper oxidised as per IS 1378) (DSR 9.57) 100x58x1.90 mm (DSR 9.57.2) 68 Providing and fixing ISI marked IS:1341 oxidised M.S. pressed butt hinges with necessary screws etc. complete. (Copper oxidised as per IS 1378) (DSR 9.57) 75x47x1.70 mm (DSR 9.57.3) 69 Providing and fixing ISI marked oxidised M.S. sliding door bolts with nuts and screws etc. complete (Copper oxidised as per IS 1378) (DSR 9.62) 250x16 mm (DSR 9.62.2) 70 Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete (Copper oxidised as per IS 1378) (DSR 9.63) 200x10 mm (DSR 9.63.2) 71 Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete (Copper oxidised as per IS 1378) (DSR 9.63) 150x10 mm (DSR 9.63.3) 72 Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete (Copper oxidised as per IS 1378) (DSR 9.66) 125 mm (DSR 9.66.1) 73 Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete (Copper oxidised as per IS 1378) (DSR 9.66) 100 mm (DSR 9.66.2) 74 Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete (Copper oxidised as per IS 1378) (DSR 9.66) 75 mm (DSR 9.66.3) 75 Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. (DSR )(DSR 10.1) 76 Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. (DSR 10.15) Fixing with carbon steel galvanised dash fastener of required dia and size (to be paid for separately) (DSR 10.15.2) 77 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. (DSR 10.16) Electric resistance or induction butt welded tubes (DSR 10.16.3) 78 Providing and fixing M.S. fan clamp type I or II of 16 mm dia M.S. bar, bent to shape with hooked ends in R.C.C. slabs or beams during laying, including painting the exposed portion of loop, all as per standard design complete. (DSR )(DSR 10.17) 79 Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing. (DSR )(DSR 10.18) 80 Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. (DSR 10.25) In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works (DSR 10.25.2) 81 Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). (DSR )(DSR 10.28) 82 Providing & fixing fly proof wire gauze to windows, clerestory windows & doors with M.S. Flat 15x3 mm and nuts & bolts complete. (DSR 10.29) Stainless steel (grade 304) wire gauze of 0.5 mm dia wire and 1.4 mm aperture on both sides (DSR 10.29.2) 83 Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : (DSR 10.3) 4.0 mm thick glass panes (DSR 10.30.1) 84 Dry brick on edge flooring in required pattern with bricks of class designation 7.5 on a bed of 12 mm mud mortar, including filling joints with Jamuna sand, with common burnt clay non modular bricks. (DSR )(DSR 11.2) 85 Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. (DSR 11.3) 40 mm thick with 20 mm nominal size stone aggregate (DSR 11.3.1) 86 Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : (DSR 11.26) 25 mm thick (DSR 11.26.1) 87 Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. (DSR )(DSR 11.27) 88 Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete. (DSR )(DSR 11.37) 89 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqmincluding grouting the joints with white cement and matching pigments etc., complete. (DSR 11.41) Size of Tile 600x600 mm (DSR 11.41.2) 90 Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge. (DSR 11.48) Size of Tile 600x600 mm (DSR 11.48.2) 91 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. (DSR 12.41) 110 mm diameter (DSR 12.41.2) 92 Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. (DSR 12.42) Coupler 12.42.1 75 mm (DSR 12.42.1.1) 93 Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. (DSR 12.42) Coupler 12.42.1 110 mm (DSR 12.42.1.2) 94 Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. (DSR 11.56) Polished Granite stone slab colour of Black, Cherry/Ruby Red or equivalent (DSR 11.56.1) 95 Providing & fixing at all heights, levels and locations Mill finish Aluminium alloy roofing sheets of alloyIS designation31500, temper Hx8 conforming to IS 737 and dimensions as per IS code 2676 with characteristics of good formability and corrosion resistance. The profile sheets shall be fixed to truss members in slope or required pitch or curvature with Hex cap headed self drilling/tapping Stainless steel screws M6, 50 mm long with 3 mm EPDM seal washer etc. all inclusive of labour, scaffolding, T&P and sundries etc. complete as per directions of the Engineer-In-Charge. (Cost of truss/frame work shall be paid separately). (DSR 12.64) 0.56 mm, Aluminium troughed profile with center to center pitch of 200 mm, depth of 32 mm, overall profile width1092 mm, cover width 1000mm. (DSR 12.64.1) 96 12 mm cement plaster of mix :CEMENT PLASTER (IN COARSE SAND) (DSR 13.4) 1:4 (1 cement: 4 coarse sand) (DSR 13.4.1) 97 12 mm cement plaster of mix :CEMENT PLASTER (IN COARSE SAND) (DSR 13.4) 1:6 (1 cement: 6 coarse sand) (DSR 13.4.2) 98 15 mm cement plaster on rough side of single or half brick wall of mix:CEMENT PLASTER (IN COARSE SAND) (DSR 13.5) 1:4 (1 cement: 4 coarse sand) (DSR 13.5.1) 99 15 mm cement plaster on rough side of single or half brick wall of mix:CEMENT PLASTER (IN COARSE SAND) (DSR 13.5) 1:6 (1 cement: 6 coarse sand) (DSR 13.5.2) 100 12 mm cement plaster finished with a floating coat of neat cement of mix : (DSR 13.7) 1:4 (1 cement: 4 fine sand) (DSR 13.7.2) 101 6 mm cement plaster of mix : (DSR 13.16) 1:3 (1 cement : 3 fine sand) (DSR 13.16.1) 102 Neat cement punning. (DSR )(DSR 13.18) 103 Pebble dash plaster upto 10 m height above ground level with a mixture of washed pebble or crushed stone 6 mm to 12.5 mm nominal size, dashed over and including fresh plaster in two layers under layer 12 mm cement plaster 1:4 (1 cement : 4 coarse sand) and top layer 10 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) mixed with 10% finely grounded hydrated lime by volume of cement. (DSR ) (DSR 13.20) 104 Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers. (DSR )(DSR 13.21) 105 Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour : (DSR 13.41) New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than50 gram/litre (DSR 13.41.1) 106 Finishing walls with Acrylic Smooth exterior paint of required shade : (DSR 13.46) New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) (DSR 13.46.1) 107 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. (DSR )(DSR 13.80) 108 Distempering with 1st quality acrylic distemper (ready mixed) having VOC (Volatile Organic Compound ) content less than 50 gram/ litre, of approved brand and manufacturerincluding applying additional coats wherever required to achieve even shade and colour(DSR 13.81) Old work (one or more coats) (DSR 13.81.1) 109 Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete (DSR )(DSR 13.88) 110 Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. (DSR )(DSR 13.91) 111 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : (DSR 13.99) One or more coats on old work (DSR 13.99.1) 112 Finishing walls with Acrylic Smooth exterior paint of required shade : (DSR 13.111) Old work (Two or more coat applied @ 1.67 ltr/ 10 sqm) on existing cement paint surface (DSR 13.111.1) 113 Finishing walls with Acrylic Smooth exterior paint of required shade : (DSR 13.111) Old work (One or more coat applied @ 0.90 ltr/10 sqm). (DSR 13.111.2) 114 Renewing glass panes, with putty and nails wherever necessary including racking out the old putty: (DSR 14.5) Float glass panes of nominal thickness 4 mm (weight not less than 10kg/sqm) (DSR 14.5.1) 115 Renewal of old putty of glass panes (length) (DSR )(DSR 14.9) 116 Disconnecting damaged overhead/terrace PVC water storage tankof any size from water supply line and removing from the terrace including shifting at ground level as per direction of Engineer-in-charge. (DSR )(DSR 14.79) 117 Providing & fixing White vitreous china water closet squatting pan (Indian type) along withS or P trap including dismantling of old WC seat and S or P trap at site complete with all operations including all necessary materials, labour and disposal of dismantled material i/c malba, all complete as per the direction of Engineer-in charge. (DSR 14.8) Orissa pattern W.C Pan of size 580x440 mm (DSR 14.80.2) 118 DismantlingW.C.Pan of all sizes including disposal of dismantled materials i/c malba all complete as per directions of Engineer-in-Charge. (DSR )(DSR 14.82) 119 Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. (DSR 15.2) Nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix) (DSR 15.2.2) 120 Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge. (DSR )(DSR 15.3) 121 Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. (DSR 15.7) In cement mortar (DSR 15.7.4) 122 Removing mortar from bricks and cleaning bricks including stacking within a lead of 50 m (stacks of cleaned bricks shall be measured): (DSR 15.8) From brick work in cement mortar (DSR 15.8.3) 123 Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : (DSR 15.12) Of area 3 sq. metres and below (DSR 15.12.1) 124 Dismantling steel work manually/ by mechanical means in built up sections without dismembering and stacking within 50 metres lead as per direction of Engineer-in-charge. (DSR )(DSR 15.19) 125 Demolishing dry brick pitching in floors, drains etc. including stacking of serviceable material and disposal of unserviceable material within 50 metres lead : (DSR )(DSR 15.24) 126 Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead of: (DSR 15.28) G.S. Sheet (DSR 15.28.1) 127 Dismantling of flushing cistern of all types (C.I./PVC/Vitrious China) including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead. (DSR )(DSR 15.52) 128 Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. (DSR )(DSR 15.56) 129 Demolishing R.C.C. work by mechanical means and stockpiling at designated locations and disposal of dismantled materials up to a lead of 1 kilometre, stacking serviceable and unserviceable material separately including cutting reinforcement bars. (DSR )(DSR 15.58) 130 Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. (DSR )(DSR 15.60) 131 Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 40 mm nominal size) in pavements, laid to required slope and camber in panels as required including consolidation finishing and tamping complete. (DSR )(DSR 16.42) 132 Extra for providing and mixing hardening compound of approved quality as per manufacturers specification in cement concrete. (DSR )(DSR 16.44) 133 Providing and fixing concertina coil fencing with punched tape concertina coil 600 mm dia 10 metre openable length ( total length 90 m), having 50 nos rounds per 6 metre length, upto 3 m height of wall with existing angle iron Y shaped placed 2.4m or 3.00 m apart and with 9 horizontal R.B.T. reinforced barbed wire, stud tied with G.I. staples and G.I. clips to retain horizontal, including necessary bolts or G.I. barbed wire tied to angle iron, all complete as per direction of Engineer-in-charge, with reinforced barbed tape(R.B.T.) / Spring core (2.5mm thick) wire of high tensile strength of 165 kg/ sq.mm with tape (0.52 mm thick) and weight 43.478 gm/ metre (cost of M.S. angle, C.C. blocks shall be paid separately) (DSR )(DSR 16.53) 134 Providing and laying 60mm thick faciory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge. (DSR )(DSR 16.68) 135 Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-in-charge. (DSR 16.7) Made of G.I. wire of dia 4 mm (DSR 16.70.1) 136 Providing and laying C.C. pavement of mix M-25 with ready mixed concrete from batching plant. The ready mixed concrete shall be laid and finished with screed board vibrator , vacuum dewatering process and finally finished by floating, brooming with wire brush etc. complete as per specifications and directions of Engineer-in-charge. (The panel shuttering work shall be paid for separately).(Note:- Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/ recoverable separately). (DSR )(DSR 16.75) 137 Deduct for using of M-20 grade concrete instead of M-25 grade concrete in C.C. pavement. (DSR )(DSR 16.76) 138 Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge. (DSR 16.78) With material conforming to Grade-II (size range 53 mm to 0.075 mm ) having CBR Value-25 (DSR 16.78.2) 139 Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed ofsand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. (DSR 16.91) 60mm thick cement concrete paver block of M-35 grade with approved colour, design & pattern. (DSR 16.91.1) 140 Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed ofsand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. (DSR 16.91) 80 mm thick C.C. paver block of M-35 grade with approved colour design and pattern. (DSR 16.91.2) 141 Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: (DSR 17.1) White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests (DSR 17.1.1) 142 Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:-(a)White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer (DSR )(DSR 17.7A) 143 Providing and fixing white vitreous china wash basin including making all connections but excluding the cost of fittings : (DSR 17.25) Flat back wash basin of size 550x400 mm (DSR 17.25.2) 144 Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. (DSR 17.28) Semi rigid pipe 17.28.1 32 mm dia (DSR 17.28.1.1) 145 Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. (DSR )(DSR 17.31) 146 Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour. (DSR 17.69) Waste coupling 31 mm dia of 79 mm length and 62mm breadth weighing not less than 45 gms (DSR 17.69.1) 147 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.(Concealed work, including cutting chases and making good the walls etc.) (DSR 18.8) 20 mm nominal dia Pipes (DSR 18.8.2) 148 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) (DSR 18.9) 25 mm nominal dia Pipes (DSR 18.9.3) 149 Providing and fixing brass bib cock of approved quality : (DSR 18.15) 20 mm nominal bore (DSR 18.15.2) 150 Providing and fixing brass stop cock of approved quality : (DSR 18.16) 20 mm nominal bore (DSR 18.16.2) 151 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : (DSR 18.17) 25 mm nominal bore (DSR 18.17.1) 152 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : (DSR 18.17) 20 mm nominal bore (DSR 18.17.1A) 153 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : (DSR 18.17) 32 mm nominal bore. (DSR 18.17.2) 154 Providing and fixing uplasticised PVC connection pipe with brass unions : (DSR 18.21) 30 cm length 18.21.1 20 mm nominal bore (DSR 18.21.1.2) 155 Providing and fixing uplasticised PVC connection pipe with brass unions : (DSR 18.21) 45 cm length 18.21.2 20 mm nominal bore (DSR 18.21.2.2) 156 Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. (DSR )(DSR 18.48) 157 Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms. (DSR )(DSR 18.65) 158 Dismantling of old S.W. pipes including breaking of joints and bed concrete stacking of useful materials near the site within 50 m lead and disposal of unserviceable materials into municipal dumps : (DSR 19.5) 100 mm diameter (DSR 19.5.1) 159 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fastenersto be paid for separately) : (DSR 21.1) For fixed portion 21.1.1 Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) (DSR 21.1.1.1) 160 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fastenersto be paid for separately) : (DSR 21.1) For fixed portion 21.1.1 Powder coated aluminium (minimum thickness of powder coating 50 micron) (DSR 21.1.1.2) 161 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fastenersto be paid for separately) : (DSR 21.1) For fixed portion 21.1.1 Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micron) (DSR 21.1.1.3) 162 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fastenersto be paid for separately) : (DSR 21.1) For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) 21.1.2 Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) (DSR 21.1.2.1) 163 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fastenersto be paid for separately) : (DSR 21.1) For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) 21.1.2 Powder coated aluminium (minimum thickness of powder coating 50 micron) (DSR 21.1.2.2) 164 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fastenersto be paid for separately) : (DSR 21.1) For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) 21.1.2 Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micron) (DSR 21.1.2.3) 165 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): (DSR 21.3) With float glass panes of 4.0 mm thickness (weight not less than 10kg/sqm) (DSR 21.3.1) 166 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): (DSR 21.3) With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm) (DSR 21.3.2) 167 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): (DSR 21.3) With float glass panes of 8 mm thickness (weight not less than 20 kg/sqm) (DSR 21.3.3) 168 Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge. (DSR 21.4) With stainless steel cover plate minimum 1.25 mm thickness (DSR 21.4.1) 169 Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge. (DSR 21.4) With brass cover plate minimum 1.25 mm thickness (DSR 21.4.2) 170 Providing and fixing powder coated aluminium work (minimum thickness of powder coating 50 micron) consisting of tee/ angle sections, of approved make conforming to IS : 733 in frames of false ceiling including aluminium angle cleats with necessary C.P. brass/ stainless steel sunk screws, aluminium perimeter angles fixed to wall with stainless steel rawl plugs @ 450 mm centre to centre and fixing the frame work to G.I. level adjusting hangers 6 mm dia. with necessary cadmium plated machine screws all complete as per approved architectural drawings and direction of the Engineer-in-charge (level adjusting hangers, ceiling cleats and expansion hold fasteners to be paid for separately). (DSR )(DSR 21.5) 171 Providing and fixing 6 mm dia. G.I. level adjusting hangers (upto 1200mm length), fixed to roof slabs by means of ceiling cleats made out of G.I. flat 40x3mm size 60 mm long and stainless steel expandable dash fastener of 12.5 mm dia and 50 mm long, complete as per direction of Engineer-in-charge. (DSR )(DSR 21.6) 172 Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double acting hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge (Door handle, lock and stopper etc.to be paid separately). (DSR )(DSR 21.18) 173 Wiring for light point/ fan point/ exhaust fan point/ call bell point with1.5 sq mm frls pvc insulated copper conductor single core cable in surface /recessed medium class pvc conduit , with modular switch ,modular plate, suitable GI box and earething the pint with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. (DSR E&M 1.10)Group A (DSR E&M 1.10.1) 174 Wiring for light/power plug with 2x4 sq. mm FRLS PVC insulatted copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. (DSR E&M 1.12) 175 Wiring for circuit/submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. (DSR E&M 1.14) 2x2.5sq. Mm + 1x2.5 sq. mm eartrh wire (DSR E&M 1.14.2) 176 Wiring for circuit/submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. (DSR E&M 1.14) 2x4sq. Mm + 1x4 sq. mm eartrh wire (DSR E&M 1.14.3) 177 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. (DSR E&M 1.21) 25mm (DSR E&M 1.21.2) 178 Supplying and fixing 6way, Double door, single pole and neutral, sheet steel, MCB distribution board, 240V, on Surface/recess,complete with tinned copper bus bar, heutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But with MCB/RCCB/Isolator) (DSR E&M 2022 2.3.1) 179 Supplying and fixing 5 amps to 32 amps rating,Single pole, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (DSR E&M 2022 2.10.1) 180 Supplying and fixing 63 amps, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.(DSR E&M 2022 2.12.2) 181 Earthing with G.I earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. (DSR E&M 2022 5.2) 182 Supply, Installation, Testing and Commissioning of 1200 mm sweep,BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required (DSR E&M 2022 19.1) 183 Concrete with 4cm gauge I class brick ballast, coarse sand (F.M. 1.8 to 2.5) and cement in proportion of 12:6:1 in foundations and under floors including supply of all materials, labour and tools and plants etc. required for proper completion. (CSI No.5.01 ) 184 Concrete work with 40 mm gauge brick ballast obtained from breaking brick bats (brick bats supplied by the department free of cost) in proportion of 12:6:1 as in CSI no. 5.01 including cost of all labour, materials, T&P etc required for proper completion of work. (CSI No. 5.20) 185 Brick work in foundation & plinth with old dismantled bricks (supplied by department free of cost) and coarse sand of F.M. 1.8 to 2.5 mortar in 1:6 including supply of all other materials, labour, removing mortar & cleaning of old & used bricks,T&P etc complete. (CSI No. 6.18) 186 Brick work in Super structure with old dismantled bricks (supplied by department free of cost) and coarse sand of F.M. 1.8 to 2.5 mortar in 1:6 including supply of all other materials, labour, removing mortar & cleaning of old & used bricks,T&P etc complete. (CSI No. 6.19) 187 S/F welded wire mesh size 75x25mm and rectangular made out of 10 SWG over M.S. angle frame with M.S. flat welded as required including cost of drilling holes, washer welding etc as required including cost of all material, labour and T&P etc. required for proper completion of work . exept cost of M.S angle and flat. (CSI No. 9.22) 188 Providing and laying SWR, PVC ( Finolex or equivalent ) pipe including cost of excavation, C.C etc including its jointing and connection, all materials, labour and T&P etc. required for proper completion of the work. (CSI No. 27.29 c) 110 mm dia 189 Supply and fixing of power plug with 15A/250 voltflushtype switch and 5 pin 15A/250V flush type universal socket in suitable M.S. box of 175mm x 100mm x 50mmsize with phenolic laminated bakelite sheet cover 3mm thick fixed with brass machine screw and cup washer. 2018 PWD 1139 190 Supply and fixing ofLED Tube Light batten fitting suitable for up to 1 X 22 watt LED tube light on surface complete in all respect. 2018 PWD 1413(A)CAT AA 191 S/F of LED Bulb 9Watt bajaj or equivalent make as approved sample and make as per direction of Engineer in charge (NSI) 192 S/F of 07 Watt LED bulb Syska or other equivalent make including cost of labour, T&P etc required for proper completion of the work (NSI) 193 Providing and lowering of 32 mm dia. uPVC column pipe Finolex/Ashirwad or equivalent make with column coupling socket etc. including cutting the pipe of required length, proper jointing the same including cost of all materials, labour, T&P etc required for proper completion of work.(NSI) 194 Supply and fixing support clamps for 32mm dia column pipes made out of MS flats, pairs of bolt-nuts etc complete with all material, labour, T&P. (CSI No. 19.24 e) 195 Supply & installation of electrical control panel of L&T / Havells or equivalent make for 1.5/2.00 pump set single phase submersible pump / pumpset containing contractor relay condenser. (CSI No. 19.31b) 196 Supply & Installation of 2.00 HP outlet 40mm dia. or more, Head 89/45, Discharge 2000/6000 LPH submersible pump of K.S.B/ CALAMA. or eqt. make including cost of labour, T&P and material required for completion of work. (CSI No. 19.32c) 197 Supply and fixing of 2.5 mm2 for pump above 1 HP and up to 3 HP submersible cable Havels or equivalent make, for submersible pump complete in all respect. (CSI No. 19.33b) 198 Supply & fixing of steel wire rope for submersible pump including cost of labour, T&P and material required for completion of work. (CSI No. 19.34) 199 Mild Steel or Iron work in heavy sizes such as trusses built up gates, door frames, record, racks roof work gates etc. wrought to required form including holes rivetting or welding where necessary and also fixing in proper position and alignment including cost when steel is to be provided by the department. (CSI No. 9.02) 200 Supply and fixing CP Nahani Trap India make of heavy approved quality complete with CI grating, including supply of all materials,labour and T&P etc. required for proper completion of the work. (CSI No. 27.21b) as above but for 100 mm.PVC trap. 201 Providing and fixing CI GRATING 100 mm dia including all materials, labour cartage T&P etc.required for proper completion of the work. (CSI No. 27.25) 202 Providing and fixing 15 mm thick Industrial tiles size 600 x 600 mm to of Johnson Endura Meteor or approved make and colour using in different sizes (thickness to be specified by the manufacturer) conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete(NSI) 203 Providing and fixing 12 mm thick Industrial tiles size 300 x 300 mm or more of Kajaria or approved make and colour using in different sizes (thickness to be specified by the manufacturer) conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete (NSI) 204 Water proofing treatment over Roof, wall, Chajjas, Balcony etc. with Engineer Plus 7 layer waterproofing system at leakage, seepage area consisting of Surface preparation roughening of surface, opening of cracks in V groove in size of 5 mm to 10 mm width, Back filling of cracks with SBR Latex, 2 layer Spraying Mixture of Aquasil-99 and Aquaprime-99 (Take 20 liter clean water+ 1 liter Engineer Plus Aquasil-99 + 2 liter. Engineer Plus Aquaprime-99 in proportion 20:1:2 This solution should not sprayed over more than 40 sqm area, 3rd Laying 90GSM fiber glass mesh with proper overlap, 4th coat of brushable mortar prepared with Engineer Plus Aquaprime-99, water & cement (Aquaprime -99 @ 0.45 kg per sqm, water @0.45 kg per sqm & cement @0.68 kg per sqm.) in the proportion of 1:1:1.5 by weight, After 4th coat allow the coating to air cure for minimum four hours, after 4 hours interval apply, 2 coat of Flexicoat-99 mixed with Water (Flexicoat-99 @0.33 kg/sqm, water @0.66 Kg per Sqm) in the proportion of 1:2 by weight in 4 hours interval. After 6th coat allow the coating to air cure for minimum 4 hours. After 4 hours interval apply, 7th coat of Engineer Plus smartcoat-99 (Smartcoat-99 @ 0.45 Ltr/sqm & water @ 1.35Ltr/sqm in the proportion of 1:3). The surface will dry within 2 hours and surface would be fully water proof and usable after a period of 24 hours and the final appearance of the coating will be gray/milky white. The rates are included the cost of all chemicals, labours, and Required T&P for Proper completion of Work.
Contract Date: Apr 29, 2026 Contract Value : 36.93 Lakh
Government Departments No of Bidders 3
Uttar Pradesh View Result →
10.
Housing Urban and Rular Development #10831693 Price Bid
Tender For Interior Furnishing Work For School At Vanakbara Bus Stop And School Near Vadlimata Temple At U.T. Of Diu-2 Round stage_ Music room Provide and install a 3000 mm in diameter and 300 mm high, circular stage supported by 50 x 50 mm thick teakwood supports, as per the sizes mentioned in the drawing. The top surface consists of a backing 19 mm thick BWR plywood (IS: 303 Grade of Century, Green Ply, Everest, or of equivalent make) and 12 mm thick teakwood planks finished with one coat of lacquer and two coats of matte/satin/glossy melamine polish as per the approved sample. The plywood and teakwood planks were fixed to the teakwood frames. The sides are covered with 12 mm thick BWP flexible plywood (Green Ply, Everest or of equivalent make) and 12 mm melamine-polished teakwood beading. Heavy-duty plastic moulded buffers are to be provided at the bottom of the approved wooden supports. All materials, including adhesives and hardware, must be approved by the consultant as per the detailed specifications in the drawing and as directed by the Engineer-in-Charge (EIC). All sizes as indicated in drawings. 3 Working table_CCTV roomProvide and install the working table, made of 19 mm thick BWR plywood (IS: 303 Grade of Century, Green Ply, Everest, or of equivalent make) on the tabletop and bottom supports, and 12 mm thick BWP plywood for drawers as per the sizes mentioned in the drawing. The tabletop surface to be finished with 1mm thick anti-scratch laminate, all the external surfaces to be finished with 1 mm thick laminate (Century, Green Lam, Royal Touché or of equivalent make), and internal surfaces and drawers to be finished with 0.8 mm thick off-white liner laminate (Century, Green Lam, Royal Touché or of equivalent make) as per the approved sample.All the edges will have 10 mm thick melamine-polished teakwood beading. The study table will include locks and drawer channels fixed with necessary hardware (Hettich, Hafele, Blum, Ozone, or of equivalent make).The drawer shutter will have recessed handles (details as per the drawing). Table will include cable management port and ventilation opening as specified in the drawing. All materials, including adhesives and hardware, must be approved by the consultant as per the detailed specifications in the drawing and as directed by the Engineer-in-Charge (EIC). All sizes as indicated in drawings. 4 Working table_Accounts room Provide and install the working table, made of 19 mm thick BWR plywood (IS: 303 Grade of Century, Green Ply, Everest, or of equivalent make) on the tabletop and bottom supports, and 12mm thick BWP plywood for drawers as per the sizes mentioned in the drawing. The tabletop surface to be finished with 1 mm thick anti-scratch laminate, all the external surfaces to be finished with 1 mm thick laminate (Century, Green Lam, Royal Touché or of equivalent make), and internal surfaces and drawers to be finished with 0.8 mm thick off-white liner laminate as per the approved sample. All the edges will have 10 mm thick melamine-polished teakwood beading. The study table will include locks and drawer channels fixed with necessary hardware (Hettich, Hafele, Blum, Ozone, or of equivalent make). The drawer shutter will have recessed handles (details as per the drawing). Table will include cable management port and ventilation opening as specified in the drawing.All materials, including adhesives and hardware, must be approved by the consultant as per the detailed specifications in the drawing and as directed by the Engineer-in-Charge (EIC). All sizes as indicated in drawings. 5 Working table–‘a’_Computer lab tableProvide and install the table, using 25 mm and 19 mm thick BWR plywood (IS: 303 Grade of Century, Green Ply, Everest, or of equivalent make) as per the sizes mentioned in the drawing. The tabletop consists of 25 mm thick plywood and 4 mm thick veneer (Century, Green Panel, Archid, Timex, or of equivalent make). The support structure consists of 19 mm thick plywood, vertical and horizontal teakwood supports. Heavy-duty plastic moulded buffers to be provided at the bottom of supports. All the external and internal surfaces to have 4 mm thick veneer (Century, Green Panel, Archid, Timex, or of equivalent make) with one coat of lacquer and approved melamine polish, while non-visible surfaces have one lacquer finish coat. All the edges will have melamine-polished teakwood beading. Table will include cable management port and ventilation opening as specified in the drawing. A sample must be approved before mass execution of the work. All materials, including adhesives and hardware, must be approved by the consultant as per the detailed specifications in the drawing and as directed by the Engineer-in-Charge (EIC). All sizes as indicated in drawings. 6 Working table–‘b’_Social science lab table / Science lab tableProvide and install the table, using 25 mm and 19 mm thick BWR plywood (IS: 303 Grade of Century, Green Ply, Everest, or of equivalent make) as per the sizes mentioned in the drawing. The tabletop consists of 25 mm thick plywood and 4 mm thick veneer (Century, Green Panel, Archid, Timex, or of equivalent make). The support structure consists of 19 mm thick plywood, vertical and horizontal teakwood supports. Heavy-duty plastic moulded buffers to be provided at the bottom of the wooden supports. Provide 75-125µm functional powder-coated (Asian, ICA, or equivalent make) MS- ‘L’ angle as per size mentioned in drawing, with horizontal teakwood frame to support tabletop. All the external and internal surfaces have a 4 mm thick veneer with one coat of lacquer and approved melamine polish, while non-visible surfaces have one lacquer finish coat. All the edges have melamine-polished teakwood beading. Table will include cable management port and ventilation opening as specified in the drawing. A sample must be approved before mass execution of the work. All materials, including adhesives and hardware, must be approved by the consultant as per the detailed specifications in the drawing and as directed by the Engineer-in-Charge (EIC). All sizes as indicated in drawings. 7 Working table– ‘c’_lab teacher’s table/lab discussion table/library discussion table Provide and install the table using 25 mm thick BWR plywood (IS: 303 Grade of Century, Green Ply, Everest, or of equivalent make) on the table top and 19 mm thick BWP Plywood as per the sizes mentioned in the drawing. The tabletop consists of 25 mm thick plywood and 4 mm thick veneer (Century, Green Panel, Archid, Timex, or of equivalent make). The support structure consists of 19 mm thick plywood, vertical and horizontal teakwood supports. Heavy-duty plastic moulded buffers to be provided at the bottom of the wooden supports. Provide 75-125µm functional powder-coated (Asian, ICA, or equivalent make) MS- ‘L’ angle as per size mentioned in drawing, with horizontal teakwood frame to support tabletop. All the external and internal surfaces have a 4mm thick veneer with one coat of lacquer and approved melamine polish. All the edges have melamine-polished teakwood beading. Table will include cable management port and ventilation opening as specified in the drawing. A sample must be approved before mass execution of the work. All materials, including adhesives and hardware, must be approved by the consultant as per the detailed specifications in the drawing and as directed by the Engineer-in-Charge (EIC). All sizes as indicated in drawings. 8 Working table–‘d’_Social science lab table / NCC roomProvide and install the table, using 25 mm and 19 mm thick BWR plywood (IS: 303 Grade of Century, Green Ply, Everest, or of equivalent make) as per the sizes mentioned in the drawing. The tabletop consists of 25 mm thick plywood and 4 mm thick veneer (Century, Green Panel, Archid, Timex, or of equivalent make). The support structure consists of 19 mm thick plywood, vertical and horizontal teakwood supports. Heavy-duty plastic moulded buffers to be provided at the bottom of supports. All the external and internal surfaces to have 4 mm thick veneer (Century, Green Panel, Archid, Timex, or of equivalent make) with one coat of lacquer and approved melamine polish, while non-visible surfaces have one lacquer finish coat. All the edges will have melamine-polished teakwood beading. Table will include cable management port and ventilation opening as specified in the drawing. A sample must be approved before mass execution of the work. All materials, including adhesives and hardware, must be approved by the consultant as per the detailed specifications in the drawing and as directed by the Engineer-in-Charge (EIC). All sizes as indicated in drawings. 9 Working table– ‘e’_Classroom teacher’s table / Staff room tableProvide and install the table using 25 mm and 19 mm thick BWR plywood (IS: 710 Grade of Century, Green Ply, Everest, or of equivalent make) as per the sizes mentioned in the drawing. The tabletop consists of 25 mm thick plywood and 4 mm thick veneer (Century, Green Panel, Archid, Timex, or of equivalent make). The support structure consists of 19 mm thick plywood, vertical and horizontal teakwood supports with one coat of lacquer and two coats of matt/satin/glossy finish melamine polish as approved by the architect, heavy-duty plastic moulded buffers to be provided at the bottom of supports. All the external and internal surfaces to have 4 mm thick veneer (Century, Green Panel, Archid, Timex, or of equivalent make) with approved melamine polish. Table will include cable management port and ventilation opening as specified in the drawing. All the edges will have melamine-polished teakwood beading. A sample must be approved before mass execution of the work. All materials, including adhesives and hardware, must be approved by the consultant as per the detailed specifications in the drawing and as directed by the Engineer-in-Charge (EIC). All sizes as indicated in drawings. 10 Working table– ‘f’_Instructor cabin table + Side storageProvide and install the table, using 25 mm and 19 mm thick BWR plywood (IS: 303 Grade of Century, Green Ply, Everest, or of equivalent make) as per the sizes mentioned in the drawing. The tabletop consists of 25 mm thick plywood and 4 mm thick veneer (Century, Green Panel, Archid, Timex, or of equivalent make). Supports and drawers to be made of 19 mm and 12 mm thick plywood. Heavy-duty plastic moulded buffers are to be provided at the bottom of the plywood, while the 45° niche drawer handle edge will have 2 mm PVC beading of Rehau polymers or an equivalent make with a similar shade of approved polish. All the external surfaces have 4 mm thick veneer with one coat of lacquer and approved melamine polish, while non-visible surfaces have one lacquer finish coat. All the internal surfaces of the drawers will have 0.8 mm thick off-white liner laminate as per the approved sample. All the edges have melamine-polished teakwood beading. Provide 75-125µm functional powder-coated (Asian, ICA, or equivalent make) MS- ‘L’ angle as per size mentioned in drawing, with horizontal surface of plywood to support the tabletop. The table includes cable management port and ventilation opening as specified in the drawing. A sample must be approved before mass execution of the work. All materials, including adhesives and hardware, must be approved by the consultant as per the detailed specifications in the drawing and as directed by the Engineer-in-Charge (EIC). All sizes as indicated in drawings. 11 Working table–‘g’_HM room table + Side storageProvide and install the table, using 25 mm and 19 mm thick BWR plywood (IS: 303 Grade of Century, Green Ply, Everest, or of equivalent make) as per the sizes mentioned in the drawing. The tabletop consists of 25 mm thick plywood and 4 mm thick veneer (Century, Green Panel, Archid, Timex, or of equivalent make). Supports and drawers to be made of 19 mm and 12 mm thick plywood. Heavy-duty plastic moulded buffers are to be provided at the bottom of the plywood, while the 45° niche drawer handle edge will have 2 mm PVC beading of Rehau polymers or an equivalent make with a similar shade of approved polish. All the external surfaces have 4 mm thick veneer with one coat of lacquer and approved melamine polish, while non-visible surfaces have one lacquer finish coat. All the internal surfaces of the drawers will have 0.8 mm thick off-white liner laminate as per the approved sample. All the edges have melamine-polished teakwood beading. Provide 75-125µm functional powder-coated (Asian, ICA, or equivalent make) MS- ‘L’ angle as per size mentioned in drawing, with horizontal surface of plywood to support the tabletop. The table includes cable management port and ventilation opening as specified in the drawing. A sample must be approved before mass execution of the work. All materials, including adhesives and hardware, must be approved by the consultant as per the detailed specifications in the drawing and as directed by the Engineer-in-Charge (EIC). All sizes as indicated in drawings. 12 Working table– ‘h’_Admin room workstationProvide and install the table using 25 mm and 19 mm thick BWR plywood (IS: 303 Grade of Century, Green Ply, Everest, or of equivalent make) as per the sizes mentioned in the drawing. The tabletop consists of 25 mm thick plywood and 4 mm thick veneer (Century, Green Panel, Archid, Timex, or of equivalent make). Supports and drawers to be made of 19 mm and 12 mm thick plywood. Heavy-duty plastic moulded buffers are to be provided at the bottom of plywood supports. All the external and surfaces have 4 mm thick veneer (Century, Green Panel, Archid, Timex, or of equivalent make) with one coat of lacquer and approved melamine polish. All the internal surfaces of the drawers will have 0.8 mm thick off-white liner laminate as per the approved sample. All the edges will have melamine-polished teakwood beading. The table includes cable management port and ventilation opening as specified in the drawing. A sample must be approved before mass execution of the work. All materials, including adhesives and hardware, must be approved by the consultant as per the detailed specifications in the drawing and as directed by the Engineer-in-Charge (EIC). All sizes as indicated in drawings. 13 Working table– ‘i’_Conference room tableProvide and install the table using 19 mm thick BWR plywood (IS: 303 Grade of Century, Green Ply, Everest, or of equivalent make), 25 x 25 mm MS box section, 5 mm thick MS plate, and an MS ‘C’ channel as per the sizes mentioned in the drawing. The tabletop consists of 19 mm thick plywood and 4 mm thick veneer (Century, Green Panel, Archid, Timex, or of equivalent make), with 10mm thick melamine-polished teakwood beading on edges. The table is supported by 75-125µm functional powder-coated MS box section frame MS base plate support as per detailed drawing. MS plate supports including 75 mm diameter MS pipe and heavy-duty plastic-moulded buffers to be provided at the bottom. All MS frame surfaces are covered with 12 mm thick plywood and 4mm thick veneer with one coat of lacquer and two coats of matte/satin/glossy finish melamine polish as approved by the architect. Provision for pop up switchboard, cable management port and ventilation opening is to be included as specified in the drawing. All materials, including adhesives and hardware, must be approved by the consultant as per the detailed specifications in the drawing and as directed by the Engineer-in-Charge (EIC). All sizes as indicated in drawings. 14 Faculty dining table Type-jProvide and install a table using 25mm thick BWP plywood (IS:710 Grade of Century, Green ply, Everest or of equivalent make) for the table top and 6mm thick BWP plywoodfor underside as per sizes mentioned in the drawing. Finish the tabletop with 4mm thick veneer (Century, Green panel, Archid, Timex or of equivalent make) and apply one coat of lacquer and two coats of matte/satin/glossy finish melamine polish as approved by the architect. All the edges will have 6mm melamine-polished teakwoodbeading. The table will be supported with vertical wooden members and wooden frame below the table top finished with melamine-polish. The buffer strips to be provided at the bottom of the wooden supports. A sample must be approved before mass execution of the work. All materials, including adhesives and hardware, must be approved by the consultant as per the detailed specifications in the drawing and as directed by the Engineer-in-Charge (EIC). All sizes as indicated in drawings. 15 Library reception tableProvide and install the ‘L’-shaped table using 19mm thick BWR plywood (IS: 303 Grade of Century, Green Ply, Everest, or of equivalent make) as per the sizes mentioned in the drawing. The lower and upper tabletop consists 19 mm thick plywood and 4 mm thick veneer (Century, Green Panel, Archid, Timex, or of equivalent make) with one coat of lacquer and two coats of matte/satin/glossy finish melamine polish as approved by the architect. Supports and drawers are to be made from 19mm and 12mm thick plywood. All the internal surfaces of the drawers will have 0.8 mm thick off-white liner laminate. The table includes 75 mm plywood skirting; 45° niche drawer handle with 2mm PVC beading of Rehau polymers or equivalent make with a shade similarto the approved polish. All the external surfaces have a 4 mm thick veneer with lacquer and approved melamine polish, while non-visible surfaces have one lacquer finish coat. All the edges have approved melamine-polished teakwood beading. The table includes cable management port and ventilation opening as specified in the drawing. All materials, including adhesives and hardware, must be approved by the consultant as per the detailed specifications in the drawing and as directed by the Engineer-in-Charge (EIC). All sizes as indicated in drawings. 16 Stackable table type- ‘a’Provide and assemble stackable table using 25 mm thick BWR plywood (IS: 303 Grade of Century, Green Ply, Everest, or of equivalent make), 8 mm thick MS plate, 15 x 15 mm MS SHS and teakwood as per the sizes and shapes mentioned in the drawing. Fabricate legs by bending and appropriate welding of MS plate and Box sections, finishing with grinding and sanding. Apply 75-125µm functional powder-coating for a durable and scratch-resistant finish. Include teakwood buffers at the bottom of the supports as per detail shown in the drawing and finish 25 mm thick plywood table top with 1 mm laminate (Century, Green Lam, Royal Touché, or of equivalent make), approved by the architect. Fix table top and legs as per detail drawing. Edges will have 10 mm thick melamine-polished teakwood beading. Rubber gaskets are provided at the table top base for stacking. A sample will have to be made for approval before mass execution of the work. All materials and hardware, must be approved by the consultant as per the detailed specifications in the drawing and as directed by the Engineer-in-Charge (EIC). All sizes as indicated in drawings. 17 Stackable table type- ‘b’Provide and assemble stackable table using 25 mm thick BWR plywood (IS: 303 Grade of Century, Green Ply, Everest, or of equivalent make), 8 mm thick MS plate, 15 x 15 mm MS SHS and teakwood as per the sizes and shapes mentioned in the drawing. Fabricate legs by bending and appropriate welding of MS plate and Box sections, finishing with grinding and sanding. Apply 75-125µm functional powder-coating for a durable and scratch-resistant finish. Include teakwood buffers at the bottom of the supports as per detail shown in the drawing and finish 25 mm thick plywood table top with 1 mm laminate (Century, Green Lam, Royal Touché, or of equivalent make), approved by the architect. Fix table top and legs as per detail drawing. Edges will have 10 mm thick melamine-polished teakwood beading. Rubber gaskets are provided at the table top base for stacking. A sample will have to be made for approval before mass execution of the work. All materials and hardware, must be approved by the consultant as per the detailed specifications in the drawing and as directed by the Engineer-in-Charge (EIC). All sizes as indicated in drawings. 18 Stackable table type- ‘c’Provide and assemble stackable table using 25 mm thick BWR plywood (IS: 303 Grade of Century, Green Ply, Everest, or of equivalent make), 8 mm thick MS plate, 15 x 15 mm MS SHS and teakwood as per the sizes and shapes mentioned in the drawing. Fabricate legs by bending and appropriate welding of MS plate and Box sections, finishing with grinding and sanding. Apply 75-125µm functional powder-coating for a durable and scratch-resistant finish. Include teakwood buffers at the bottom of the supports as per detail shown in the drawing and finish 25 mm thick plywood table top with 1 mm laminate (Century, Green Lam, Royal Touché, or of equivalent make), approved by the architect. Fix table top and legs as per detail drawing. Edges will have 10 mm thick melamine-polished teakwood beading. Rubber gaskets are provided at the table top base for stacking. A sample will have to be made for approval before mass execution of the work. All materials and hardware, must be approved by the consultant as per the detailed specifications in the drawing and as directed by the Engineer-in-Charge (EIC). All sizes as indicated in drawings. 19 Stackable table type- ‘d’Provide and assemble stackable table using 25 mm thick BWR plywood (IS: 303 Grade of Century, Green Ply, Everest, or of equivalent make), 8 mm thick MS plate, 15 x 15 mm MS SHS and teakwood as per the sizes and shapes mentioned in the drawing. Fabricate legs by bending and appropriate welding of MS plate and Box sections, finishing with grinding and sanding. Apply 75-125µm functional powder-coating for a durable and scratch-resistant finish. Include teakwood buffers at the bottom of the supports as per detail shown in the drawing and finish 25 mm thick plywood table top with 1 mm laminate (Century, Green Lam, Royal Touché, or of equivalent make), approved by the architect. Fix table top and legs as per detail drawing. Edges will have 10 mm thick melamine-polished teakwood beading. Rubber gaskets are provided at the table top base for stacking. A sample will have to be made for approval before mass execution of the work. All materials and hardware, must be approved by the consultant as per the detailed specifications in the drawing and as directed by the Engineer-in-Charge (EIC). All sizes as indicated in drawings. 20 Curved seating_ Music roomProvide and install curved and circular sitting furniture, as per sizes and shapes mentioned in the drawing, supported by teakwood frame supports. The top surface consists of a backing of 19 mm thick BWR plywood (IS: 303 Grade of Century, Green Ply, Everest, or equivalent make), covered with 75 mm foam. Sides will be covered with 25 mm thick foam on 12 mm thick BWP flexible plywood (Green Ply, Everest or of equivalent make). The top and sides is to be finished with the selected fabric. The lower edge of the sitting area will be framed with 6 mm thick plywood for fabric fixation. All materials, including adhesives and hardware, must be approved by the consultant according to the detailed specifications in the drawing and as directed by the Engineer-in-Charge (EIC). All sizes as indicated in drawings. 21 Circular seating_ Music roomProvide and install curved and circular sitting furniture, as per sizes and shapes mentioned in the drawing, supported by teakwood frame supports. The top surface consists of a backing of 19 mm thick BWR plywood (IS: 303 Grade of Century, Green Ply, Everest, or equivalent make), covered with 75 mm foam. Sides will be covered with 25 mm thick foam on12 mm thick BWP flexible plywood (Green Ply, Everest or of equivalent make). The top and sides is to be finished with the selected fabric. The lower edge of the sitting area will be framed with 6 mm thick plywood for fabric fixation. All materials, including adhesives and hardware, must be approved by the consultant according to the detailed specifications in the drawing and as directed by the Engineer-in-Charge (EIC). All sizes as indicated in drawings. 22 Seating outside computer labProvide and install column to column seating, supported by MS supports as per the detailed drawing. The top surface consists of teakwood planks fixed on 19 mm thick plywood BWR plywood (IS: 303 Grade of Century, Green Ply, Everest, or equivalent make), supported by four brackets fabricated from 8 mm MS plates, as per design. Additionally, one coat of lacquer and two coats of matte/satin/glossy finish melamine-polished teakwood planks and beading shall cover the MS supports with a seamless finish. All materials include adhesives and hardware must be approved by the consultant according to the detailed specifications in the drawing and as directed by the Engineer-in-Charge (EIC). All sizes as indicated in drawings. 23 Waiting area seating_ Admin roomProvide and install a wall-to-wall seat, supported by MS supports as per the detailed drawing. The top surface consists of teakwood planks fixed on 19 mm thick plywood BWR plywood (IS: 303 Grade of Century, Green Ply, Everest, or equivalent make), supported by 75-125µm functional powder-coated MS box sections and four brackets fabricated from 8 mm MS plates, as per design. Additionally, one coat of lacquer and two coats of matte/satin/glossy finish melamine-polished teakwood planks and beading shall cover the MS box sections with a seamless finish. All materials include adhesives and hardware must be approved by the consultant according to the detailed specifications in the drawing and as directed by the Engineer-in-Charge (EIC). All sizes as indicated in drawings. 24 Library racks type-‘a’ Provide and install a library rack using 8 mm and 19 mm thick BWR plywood (IS: 303 Grade of Century, Green Ply, Everest, or of equivalent make) as per the sizes mentioned in the drawing. All the external and internal surfaces have 4mm thick veneer with one coat of lacquer and two coats of matte/satin/glossy finish melamine polish as approved by the architect. All the edges have approved melamine-polished teakwood beading as per detailed drawing. The rack includes 75-125µm functional powder-coated MS name plates bolted onto shelves as per detailed drawing. A sample must be approved before mass execution of the work. All materials, including adhesives and hardware, must be approved by the consultant according to the detailed specifications in the drawing and as directed by the Engineer-in-Charge (EIC). All sizes as indicated in drawings. 25 Library racks type-‘b’Provide and install a library rack using 8 mm and 19 mm thick BWR plywood (IS: 303 Grade of Century, Green Ply, Everest, or of equivalent make) as per the sizes mentioned in the drawing. All the external and internal surfaces have 4mm thick veneer with one coat of lacquer and two coats of matt/satin/glossy finish melamine polish as approved by the architect. All the edges have approved melamine-polished teakwood beading as per detailed drawing. The rack includes 75-125µm functional powder-coated MS name plates bolted onto shelves as per detailed drawing. A sample must be approved before mass execution of the work. All materials, including adhesives and hardware, must be approved by the consultant according to the detailed specifications in the drawing and as directed by the Engineer-in-Charge (EIC). All sizes as indicated in drawings. 26 Type-c (single side racks)Provide and install a library rack using 8 mm and 19 mm thick BWR plywood (IS: 303 Grade of Century, Green Ply, Everest, or of equivalent make) as per the sizes mentioned in the drawing. All the external and internal surfaces have 4mm thick veneer with one coat of lacquer and two coats of matte/satin/glossy finish melamine polish as approved by the architect. All the edges have approved melamine-polished teakwood beading as per detailed drawing. The rack includes 75-125µm functional powder-coated MS name plates bolted onto shelves as per detailed drawing. A sample must be approved before mass execution of the work. All materials, including adhesives and hardware, must be approved by the consultant according to the detailed specifications in the drawing and as directed by the Engineer-in-Charge (EIC). All sizes as indicated in drawings. 27 Cupboard_Instructor’s cabin + seatProvide and install the Cupboard made of 19 mm thick BWR plywood (IS: 303 Grade of Century, Green Ply, Everest, or of equivalent make), with one coat of lacquer and two coats of matte/satin/glossy finish melamine-polished teakwood shutters and shelves according to the sizes mentioned in the drawing. The cupboard comprises two closed units separated by open shelves. The sides, bottom, shutter, and shelves are to be made of 12 mm, 19 mm and 25 mm thick plywood and back side to be made of 8 mm thick plywood. All the internal surfaces will have 0.8 mm thick off-white liner laminate and all the external surface will have 1mm thick laminate (Century, Green Lam, Royal Touché or of equivalent make), as approved by the architect. All the internal shelf edges will have 10 mm thick approved melamine-polished teakwood beading. The cupboard will include locks, stoppers, hinges, powder-coated MS pipe, drawer channels and magnet fixed with necessary hardware (Hettich, Hafele, Blum, Ozone, or of equivalent make). The shutter will have recessed handles and 8 mm Saint Gobain glass with flat edges to be fixed with a teakwood frame using silicon and teakwood beading as per the drawing. Additionally, a seating space as detailed in the drawing is featured at the back of the cupboard, assembled from 19 mm and 25 mm plywood (IS: 710 Grade of Century, Green Ply, Everest, or of equivalent make). This seating will be covered with 10 mm thick teakwood beading and 1 mm laminate (Century, Green Lam, Royal Touché or of equivalent make), as per selection. All materials, including adhesives and hardware, must be approved by the consultant as per the detailed specifications in the drawing and as directed by the Engineer-in-Charge (EIC).All sizes as indicated in drawings. 28 Cupboard _ CCTV roomProvide and install an ‘L’-shaped cupboard made of 19 mm thick BWR plywood (IS: 303 Grade of Century, Green Ply, Everest, or of equivalent make), with one coat of lacquer and two coats of matte/satin/glossy finish melamine-polished teakwood shutters and shelves according to the sizes mentioned in the drawing. The sides, bottom, shutter, and internal shelves are to be made of 12 mm, 19 mm, and 25 mm thick plywood and back side to be made of 8 mm thick plywood. All the internal surfaces will have 0.8 mm thick off-white liner laminate and all the external surfaces will have 1 mm thick laminate (Century, Green Lam, Royal Touché or of equivalent make), as approved by the architect. All the internal shelf edges will have 10 mm thick approved melamine-polished teakwood beading. The cupboard will include locks, stoppers, hinges, powder-coated MS pipe, drawer channels, and magnate fixed with necessary hardware (Hettich, Hafele, Blum, Ozone, or of equivalent make). The shutter will have recessed handles and 8 mm Saint Gobain glass with flat edges to be fixed with a teakwood frame using silicon and teakwood beading with location and size as per the drawing. All materials, including adhesives and hardware, must be approved by the consultant as per the detailed specifications in the drawing and as directed by the Engineer-in-Charge (EIC). All sizes as indicated in drawings. 29 Cupboard _ Accounts room Provide and install a cupboard, made of 19 mm thick BWR plywood (IS: 303 Grade of Century, Green Ply, Everest, or of equivalent make), with one coat of lacquer and two coats of matte/satin/glossy finish melamine-polished teakwood shutters and shelves according to the sizes mentioned in the drawing. The sides, bottom, shutter, and internal shelves are to be made of 12 mm, 19 mm and 25 mm thick plywood and the back side is to be made of 8 mm thick plywood. All the internal surfaces will have 0.8 mm thick off-white liner laminate and all the external surface will have 1 mm thick laminate (Century, Green Lam, Royal Touché, or of equivalent make), as approved by the architect. All the internal shelf edges will have 10 mm thick approved melamine-polished teakwood beading. The cupboard will include locks, stoppers, hinges, powder-coated MS pipe, drawer channels, and magnet fixed with necessary hardware (Hettich, Hafele, Blum, Ozone, or of equivalent make). The shutter will have recessed handles and 8 mm Saint Gobain glass with flat edges to be fixed with a teakwood frame using silicon and teakwood beading with location and size as per the drawing. All materials, including adhesives and hardware, must be approved by the consultant as per the detailed specifications in the drawing and as directed by the Engineer-in-Charge (EIC). All sizes as indicated in drawings. 30 Cupboard types_Sports RoomProvide and install a cupboard, made in three parts using 19 mm thick BWR plywood (IS: 303 Grade of Century, Green Ply, Everest, or of equivalent make), with one coat of lacquer and two coats of matt/satin/glossy finish melamine-polished teakwood shutters and shelves according to the sizes mentioned in the drawing. The sides, back, bottom, shutter, and internal shelves are to be made of 12 mm and 19 mm thick plywood. All the internal surfaces will have 0.8 mm thick liner laminate of VIR laminates (SF2001 off white), and the external surface will have 1 mm thick laminate (Century, Green Lam, Royal Touché, or of equivalent make), as approved by the architect. The lower shutter will have polished 4 mm thick veneer (Century, Green Panel, Archid, Timex, or of equivalent make), recessed handles, while the upper shutter includes 8 mm Saint Gobain glass with flat edges, fixed with a teakwood frame using silicon and teakwood beading as per detailed drawing. The center part of the cabinet includes drawer with veneer finish.All the internal shelf edges will have melamine-polished 10 mm thick teakwood beading. The cupboard will include locks, stoppers, hinges, powder-coated MS pipe, drawer channels, and magnate fixed with necessary hardware (Hettich, Hafele, Blum, Ozone, or of equivalent make). This also will include installing a writing board assembly, comprising a white board, niche for smart LCD and duster holder. All materials, including adhesives and hardware, must be approved by the consultant as per the detailed specifications in the drawing and as directed by the Engineer-in-Charge (EIC). 31 Cupboard types ‘a’_Admin roomProvide and install a cupboard, made with 19 mm thick BWR plywood (IS: 303 Grade of Century, Green Ply, Everest, or of equivalent make), with one coat of lacquer and two coats of matte/satin/glossy finish melamine-polished teakwood shutters and shelves according to the sizes mentioned in the drawing. The sides, back, bottom, shutter, and internal shelves are to be made of 12 mm and 19 mm thick plywood. All the internal surfaces will have 0.8 mm thick off-white liner laminate, and the external surface will have 1 mm thick laminate (Century, Green Lam, Royal Touché, or of equivalent make), as approved by the architect. The shutter will have 8 mm Saint Gobain glass with flat edges, fixed with a teakwood frame using silicon and teakwood beading as per detailed drawing.All the internal shelf edges will have 10 mm thick melamine-polished teakwood beading. The cupboard will include locks, stoppers, hinges, powder-coated MS pipe, drawer channels, and magnate fixed with necessary hardware (Hettich, Hafele, Blum, Ozone, or of equivalent make). All materials, including adhesives and hardware, must be approved by the consultant as per the detailed specifications in the drawing and as directed by the Engineer-in-Charge (EIC). All sizes as indicated in drawings. 32 Cupboard types ‘b’_Staff roomProvide and install a cupboard, made in two parts using 19 mm thick BWR plywood (IS: 710 Grade of Century, Green Ply, Everest, or of equivalent make), with one coat of lacquer and two coats of matt/satin/glossy finish melamine-polished teakwood shutters and shelves according to the sizes mentioned in the drawing. The sides, back, bottom, shutter, and internal shelves are to be made of 12 mm and 19 mm thick plywood. All the internal surfaces will have 0.8 mm thick off-white liner laminate, and the external surface will have 1 mm thick laminate (Century, Green Lam, Royal Touché, or of equivalent make), as approved by the architect. The lower shutter will have polished 4 mm thick veneer (Century, Green Panel, Archid, Timex, or of equivalent make), recessed handles, while the upper shutter includes 8 mm Saint Gobain glass with flat edges, fixed with a teakwood frame using silicon and teakwood beading as per detailed drawing.All the internal shelf edges will have 10 mm thick melamine-polished teakwood beading. The cupboard will include locks, stoppers, hinges, powder-coated MS pipe, drawer channels, and magnate fixed with necessary hardware (Hettich, Hafele, Blum, Ozone, or of equivalent make). All materials, including adhesives and hardware, must be approved by the consultant as per the detailed specifications in the drawing and as directed by the Engineer-in-Charge (EIC). All sizes as indicated in drawings. 33 Cupboard types ‘c’_Staff room / Atal Tinkering LabProvide and install a cupboard, made in two parts using 19 mm thick BWR plywood (IS: 710 Grade of Century, Green Ply, Everest, or of equivalent make), with one coat of lacquer and two coats of matt/satin/glossy finish melamine-polished teakwood shutters and shelves according to the sizes mentioned in the drawing. The sides, back, bottom, shutter, and internal shelves are to be made of 12 mm and 19 mm thick plywood. All the internal surfaces will have 0.8 mm thick liner laminate of VIR laminates (SF2001 off white), and the external surface will have 1 mm thick laminate (Century, Green Lam, Royal Touché, or of equivalent make), as approved by the architect. The lower shutter will have polished 4 mm thick veneer (Century, Green Panel, Archid, Timex, or of equivalent make), recessed handles, while the upper shutter includes 8 mm Saint Gobain glass with flat edges, fixed with a teakwood frame using silicon and teakwood beading as per detailed drawing.All the internal shelf edges will have melamine-polished 10 mm thick teakwood beading. The cupboard will include locks, stoppers, hinges, powder-coated MS pipe, drawer channels, and magnate fixed with necessary hardware (Hettich, Hafele, Blum, Ozone, or of equivalent make). All materials, including adhesives and hardware, must be approved by the consultant as per the detailed specifications in the drawing and as directed by the Engineer-in-Charge (EIC). All sizes as indicated in drawings. 34 Cupboard types ‘d’_LibraryProvide and install a cupboard using 19 mm thick BWR plywood (IS: 303 Grade of Century, Green Ply, Everest, or of equivalent make) and 12 mm thick plywood for shelves according to the sizes mentioned in the drawing. All the internal surfaces will have 0.8 mm thick off-white liner laminate, and the external surfaces will have 1 mm thick laminate (Century, Green Lam, Royal Touché, or of equivalent make), as approved by the architect. The shutters will be finished with one coat of lacquer and two coats of matte/satin/glossy finish melamine- polished 4 mm thick veneer (Century, Green Panel, Archid, Timex, or of equivalent make) and will have recessed handles as per detailed drawing. All the internal shelf edges will have 10 mm thick melamine-polished teakwood beading. The cupboard will include locks, stoppers, hinges, powder-coated MS pipe, drawer channels, and magnate fixed with necessary hardware (Hettich, Hafele, Blum, Ozone, or of equivalent make). All materials, including adhesives and hardware, must be approved by the consultant as per the detailed specifications in the drawing and as directed by the Engineer-in-Charge (EIC). All sizes as indicated in drawings. 35 Cupboard types ‘e’_Conference roomProvide and install a cupboard using 19 mm thick BWR plywood (IS: 303 Grade of Century, Green Ply, Everest, or of equivalent make) and 12 mm thick plywood for shelves according to the sizes mentioned in the drawing. All the internal surfaces will have 0.8 mm thick off-white liner laminate, and the external surfaces will have 1 mm thick laminate (Century, Green Lam, Royal Touché, or of equivalent make), as approved by the architect. The shutters will be finished with one coat of lacquer and two coats of matte/satin/glossy finish melamine- polished 4 mm thick veneer (Century, Green Panel, Archid, Timex, or of equivalent make) and will have recessed handles as per detailed drawing. All the internal shelf edges will have 10 mm thick melamine-polished teakwood beading. The cupboard will include locks, stoppers, hinges, powder-coated MS pipe, drawer channels, and magnate fixed with necessary hardware (Hettich, Hafele, Blum, Ozone, or of equivalent make). All materials, including adhesives and hardware, must be approved by the consultant as per the detailed specifications in the drawing and as directed by the Engineer-in-Charge (EIC). All sizes as indicated in drawings. 36 Cupboard types ‘f’_Conference roomProvide and install a cupboard using 19 mm thick BWR plywood (IS: 303 Grade of Century, Green Ply, Everest, or of equivalent make) and 12 mm thick plywood for shelves according to the sizes mentioned in the drawing. All the internal surfaces will have 0.8 mm thick off-white liner laminate, and the external surfaces will have 1 mm thick laminate (Century, Green Lam, Royal Touché, or of equivalent make), as approved by the architect. The shutters will be finished with one coat of lacquer and two coats of matte/satin/glossy finish melamine- polished 4 mm thick veneer (Century, Green Panel, Archid, Timex, or of equivalent make) and will have recessed handles as per detailed drawing. All the internal shelf edges will have 10 mm thick melamine-polished teakwood beading. The cupboard will include locks, stoppers, hinges, powder-coated MS pipe, drawer channels, and magnate fixed with necessary hardware (Hettich, Hafele, Blum, Ozone, or of equivalent make). All materials, including adhesives and hardware, must be approved by the consultant as per the detailed specifications in the drawing and as directed by the Engineer-in-Charge (EIC). All sizes as indicated in drawings. 37 Cupboard types ‘g’_Conference roomProvide and install a cupboard using 19 mm thick BWR plywood (IS: 303 Grade of Century, Green Ply, Everest, or of equivalent make) and 12 mm thick plywood for shelves according to the sizes mentioned in the drawing. All the internal surfaces will have 0.8 mm thick off-white liner laminate, and the external surfaces will have 1 mm thick laminate (Century, Green Lam, Royal Touché, or of equivalent make), as approved by the architect. The shutters will be finished with one coat of lacquer and two coats of matte/satin/glossy finish melamine- polished 4 mm thick veneer (Century, Green Panel, Archid, Timex, or of equivalent make) and will have recessed handles as per detailed drawing. All the internal shelf edges will have 10 mm thick melamine-polished teakwood beading. The cupboard will include locks, stoppers, hinges, powder-coated MS pipe, drawer channels, and magnate fixed with necessary hardware (Hettich, Hafele, Blum, Ozone, or of equivalent make). All materials, including adhesives and hardware, must be approved by the consultant as per the detailed specifications in the drawing and as directed by the Engineer-in-Charge (EIC). All sizes as indicated in drawings. 38 Cupboard types ‘h’_Conference roomProvide and install a cupboard using 19 mm thick BWR plywood (IS: 303 Grade of Century, Green Ply, Everest, or of equivalent make) and 12 mm thick plywood for shelves according to the sizes mentioned in the drawing. All the internal surfaces will have 0.8 mm thick off-white liner laminate, and the external surfaces will have 1 mm thick laminate (Century, Green Lam, Royal Touché, or of equivalent make), as approved by the architect. The shutters will be finished with one coat of lacquer and two coats of matte/satin/glossy finish melamine- polished 4 mm thick veneer (Century, Green Panel, Archid, Timex, or of equivalent make) and will have recessed handles as per detailed drawing. All the internal shelf edges will have 10 mm thick melamine-polished teakwood beading. The cupboard will include locks, stoppers, hinges, powder-coated MS pipe, drawer channels, and magnate fixed with necessary hardware (Hettich, Hafele, Blum, Ozone, or of equivalent make). All materials, including adhesives and hardware, must be approved by the consultant as per the detailed specifications in the drawing and as directed by the Engineer-in-Charge (EIC). All sizes as indicated in drawings. 39 Cupboard types ‘i’_Staff roomProvide and install a cupboard, made in two parts using 19 mm thick BWR plywood (IS: 303 Grade of Century, Green Ply, Everest, or of equivalent make), according to the sizes of shelves mentioned in the drawing, with teakwood shutters on top finished with one coat of lacquer and two coats of matte/satin/glossy melamine-polish, as approved by the architect. The sides, back, bottom, lower shutters, and internal shelves are to be made of 12 mm and 19 mm thick plywood, as mentioned in the drawings. All the internal surfaces will have 0.8 mm thick off-white liner laminate, and the external surface will have 1 mm thick laminate (Century, Green Lam, Royal Touché, or of equivalent make), as approved by the architect. The lower shutter will have polished 4 mm thick veneer (Century, Green Panel, Archid, Timex, or of equivalent make), recessed handles, while the upper shutter includes 8 mm Saint Gobain glass with flat edges, fixed with a teakwood frame using silicon and teakwood beading as per detailed drawing.All the internal shelf edges will have 10 mm thick melamine-polished teakwood beading. The cupboard will include locks, stoppers, hinges, powder-coated MS pipe, drawer channels, and magnet fixed with necessary hardware (Hettich, Hafele, Blum, Ozone, or of equivalent make). All materials, including adhesives and hardware, must be approved by the consultant as per the detailed specifications in the drawing and as directed by the Engineer-in-Charge (EIC). All sizes as indicated in drawings. 40 Cupboard types ‘j’_Admin roomProvide and install a cupboard, made in two parts using 19 mm thick BWR plywood (IS: 303 Grade of Century, Green Ply, Everest, or of equivalent make), with one coat of lacquer and two coats of matte/satin/glossy finish melamine-polished teakwood shutters and shelves according to the sizes mentioned in the drawing. The sides, back, bottom, shutter, and internal shelves are to be made of 12 mm and 19 mm thick plywood. All the internal surfaces will have 0.8 mm thick off-white liner laminate, and the external surface will have 1 mm thick laminate (Century, Green Lam, Royal Touché, or of equivalent make), as approved by the architect. The lower shutter will have polished 4 mm thick veneer (Century, Green Panel, Archid, Timex, or of equivalent make), recessed handles, while the upper shutter includes 8 mm Saint Gobain glass with flat edges, fixed with a teakwood frame using silicon and teakwood beading as per detailed drawing.All the internal shelf edges will have10 mm thick melamine-polished teakwood beading. The cupboard will include locks, stoppers, hinges, powder-coated MS pipe, drawer channels, and magnate fixed with necessary hardware (Hettich, Hafele, Blum, Ozone, or of equivalent make). All materials, including adhesives and hardware, must be approved by the consultant as per the detailed specifications in the drawing and as directed by the Engineer-in-Charge (EIC). All sizes as indicated in drawings. 41 Cupboard types ‘k’_Staff roomProvide and install a cupboard, made in two parts using 19 mm thick BWR plywood (IS: 303 Grade of Century, Green Ply, Everest, or of equivalent make), according to the sizes of shelves mentioned in the drawing, with teakwood shutters on top finished with one coat of lacquer and two coats of matte/satin/glossy melamine-polish, as approved by the architect. The sides, back, bottom, lower shutters, and internal shelves are to be made of 12 mm and 19 mm thick plywood, as mentioned in the drawings. All the internal surfaces will have 0.8 mm thick off-white liner laminate, and the external surface will have 1 mm thick laminate (Century, Green Lam, Royal Touché, or of equivalent make), as approved by the architect. The lower shutter will have polished 4 mm thick veneer (Century, Green Panel, Archid, Timex, or of equivalent make), recessed handles, while the upper shutter includes 8 mm Saint Gobain glass with flat edges, fixed with a teakwood frame using silicon and teakwood beading as per detailed drawing.All the internal shelf edges will have 10 mm thick melamine-polished teakwood beading. The cupboard will include locks, stoppers, hinges, powder-coated MS pipe, drawer channels, and magnet fixed with necessary hardware (Hettich, Hafele, Blum, Ozone, or of equivalent make). All materials, including adhesives and hardware, must be approved by the consultant as per the detailed specifications in the drawing and as directed by the Engineer-in-Charge (EIC). All sizes as indicated in drawings. 42 Cupboard types ‘l’_Admin roomProvide and install a cupboard using 19 mm thick BWR plywood (IS: 303 Grade of Century, Green Ply, Everest, or of equivalent make) and 12 mm thick plywood for shelves according to the sizes mentioned in the drawing. All the internal surfaces will have 0.8 mm thick off-white liner laminate, and the external surfaces will have 1 mm thick laminate (Century, Green Lam, Royal Touché, or of equivalent make), as approved by the architect. The shutters will be finished with one coat of lacquer and two coats of matte/satin/glossy finish melamine- polished 4 mm thick veneer (Century, Green Panel, Archid, Timex, or of equivalent make) and will have recessed handles as per detailed drawing. All the internal shelf edges will have 10 mm thick melamine-polished teakwood beading. The cupboard will include locks, stoppers, hinges, powder-coated MS pipe, drawer channels, and magnate fixed with necessary hardware (Hettich, Hafele, Blum, Ozone, or of equivalent make). All materials, including adhesives and hardware, must be approved by the consultant as per the detailed specifications in the drawing and as directed by the Engineer-in-Charge (EIC). All sizes as indicated in drawings. 43 Cupboard types ‘m’_Staff roomProvide and install a cupboard using 19 mm thick BWR plywood (IS: 303 Grade of Century, Green Ply, Everest, or of equivalent make) and 12 mm thick plywood for shelves according to the sizes mentioned in the drawing. All the internal surfaces will have 0.8 mm thick off-white liner laminate, and the external surfaces will have 1 mm thick laminate (Century, Green Lam, Royal Touché, or of equivalent make), as approved by the architect. The shutters will be finished with one coat of lacquer and two coats of matte/satin/glossy finish melamine- polished 4 mm thick veneer (Century, Green Panel, Archid, Timex, or of equivalent make) and will have recessed handles as per detailed drawing.All the internal shelf edges will have 10 mm thick melamine-polished teakwood beading. The cupboard will include locks, stoppers, hinges, powder-coated MS pipe, drawer channels, and magnate fixed with necessary hardware (Hettich, Hafele, Blum, Ozone, or of equivalent make). All materials, including adhesives and hardware, must be approved by the consultant as per the detailed specifications in the drawing and as directed by the Engineer-in-Charge (EIC). All sizes as indicated in drawings. 44 Kitchen / pantry / Toilet / Lab: Under the counter cabinet :Provide and install the under the counter cabinet, made of 19 mm thick and 12 mm thick BWR plywood (IS: 303 Grade of Century, Green Ply, Everest, or of equivalent make) as per the sizes mentioned in the drawing. The shutters and side supports are to be made with 19 mm thick plywood and 12 mm thick plywood to be used in the rear. All the external surfaces to have 1 mm thick laminate (Century, Green Lam, Royal Touché or equivalent make), as approved by the architect. All the internal surfaces to have 0.8 mm thick off-white laminate, as approved by the architect. The cabinet will include hinges and magnet fixed with necessary hardware (Hettich, Hafele, Blum, Ozone, or of equivalent make). The cabinet shutter will have bare aluminium finish profile handles of the approved make. A sample will have to be made for approval before mass execution of the work. All materials, including adhesives and hardware, must be approved by the consultant as per the detailed specifications in the drawing and as directed by the Engineer-in-Charge (EIC). All sizes as indicated in drawings. 45 Kitchen / pantry: Under the counter drawerProvide and install the under the counter drawer, made of 19 mm thick and 12 mm thick BWR plywood (IS: 303 Grade of Century, Green Ply, Everest, or equivalent make) as per the sizes mentioned in the drawing. The shutters are to be made with 19 mm thick plywood and 12 mm thick plywood to make the drawer boxes. All the external surfaces to have 1 mm thick laminate (Century, Green Lam, Royal Touché or of equivalent make) and all the internal surfaces and drawers to have 0.8 mm thick off-white laminate, as approved by the architect.The drawers will have channels fixed with necessary hardware (Hettich, Hafele, Blum, Ozone, or of equivalent make). Drawer shutters will have bare aluminium finish profile handles of the approved make. A sample will have to be made for approval before mass execution of the work. All materials, including adhesives and hardware, must be approved by the consultant as per the detailed specifications in the drawing and as directed by the Engineer-in-Charge (EIC). All sizes as indicated in drawings. 46 Writing Board (Type -a )Provide and install a writing board assembly, comprising a white board and green sliding board using 19 mm and 12 mm thick BWR plywood (IS: 303 Grade of Century, Green Ply, Everest, or of equivalent make) with teakwood framing and aluminium sliding channels as per the sizes mentioned in the drawing. The assembly includes 8 mm thick frosted glass (etched finish with grid lines) with two coats of green enamel paint, framed with 38 mm wide sliding aluminium sections and polished teakwood beading along all edges. Provide a fixed white magnetic board (Alkon or of equivalent make) according to the sizes mentioned in the drawing. Necessary heavy-duty hardware shall be used for securing the aluminium sliding assembly. All the external surfaces to have 1 mm thick laminate (Century, Green Lam, Royal Touché or of equivalent make) and all the teakwood polished with one coat of lacquer and two coats of matte/satin/glossy finish melamine-polish as approved by the architect. All the edges have approved 12mm thick melamine-polished teakwood beading as per detailed drawing. Additionally, fix the LCD TV as directed by the concerned department. The contractor shall package, transport, and install the LCD TVs, ensuring damage – free delivery. The scope encompasses timely completion, compliance with client instruction, a smart LCD stand on the back wall, chalk and duster holders, necessary studs, fasteners, and hardware. A sample will have to be made for approval before mass execution of the work. All materials, including adhesives and hardware, must be approved by the consultant as per the detailed specifications in the drawing and as directed by the Engineer-in-Charge (EIC). All sizes as indicated in drawings. 47 Writing Board (Type -b)Provide and install a writing board assembly, comprising a white board, niche for smart LCD and duster holder using 19 mm and 12 mm thick BWR plywood (IS: 303 Grade of Century, Green Ply, Everest, or of equivalent make) as per the sizes mentioned in the drawing. The assembly includes teakwood frame and 12 mm thick melamine-polished teakwood beading with white magnetic board (Alkon or of equivalent make) according to the sizes mentioned in the drawing. All the external surfaces to have 1 mm thick laminate (Century, Green Lam, Royal Touché or of equivalent make) and all the teakwood polished with one coat of lacquer and two coats of matte/satin/glossy finish melamine-polish as approved by the architect. Additionally, fix the LCD TV as directed by the concerned department. The contractor shall package, transport, and install the LCD TVs, ensuring damage – free delivery. The scope encompasses timely completion, compliance with client instruction, a smart LCD stand on the back wall, chalk and duster holders, necessary studs, fasteners, and hardware. A sample will have to be made for approval before mass execution of the work. All materials, including adhesives and hardware, must be approved by the consultant as per the detailed specifications in the drawing and as directed by the Engineer-in-Charge (EIC). All sizes as indicated in drawings. 48 Lectern/PodiumProvide and install a Lectern as per size mentioned in the drawing using 19 mm and 12 mm thick plywood (IS: 710 Grade of Century, Green Ply, Everest, or of equivalent make). The cabinet is divided horizontally into two parts. The cabinet is made with 12 mm thick plywood shutters. The external surface will have 1 mm thick laminate (Century, Green Lam, Royal Touché, or of equivalent make), approved by the architect, and internal surfaces of plywood are polished with one coat of lacquer. The longer shutters shall be provided with PVD/ZINC-coated SS D-shaped handles with mortice lock externally and tower bolt internally on the opposite shutter. The shorter shutters shall be given aluminium knobs. 75-125µm functional powder-coated MS SHS (size mentioned in drawing) is to be provided at the all the corners and in the center of the total height. Melamine-polished teakwood beading is to be provided as shown in drawing. Table will include cable management port and ventilation opening as specified in the drawing. A sample will have to be made for approval before mass execution of the work. All materials, including adhesives and hardware, must be approved by the consultant as per the detailed specifications in the drawing and as directed by the Engineer-in-Charge (EIC). All sizes as indicated in drawings. 49 Map Stand _Social science labAssemble a freestanding stand using 50 x 50 mm MS SHS, 5 mm thick MS plate and 5 mm thick solid bar as per the sizes mentioned in the drawing. Provide 600 mm wide support with rubber strips at the bottom fabricated with 50 x 50 mm MS SHS and 5 mm thick MS plate. Integrate 5 mm thick metal hooks, welded into the vertical supports of the stand as a map holder. Finish metal welds with grinding and sanding. Apply 75-125µm functional powder-coated for a durable and scratch-resistant finish. A sample will have to be made for approval before mass execution of the work. All materials and hardware, must be approved by the consultant as per the detailed specifications in the drawing and as directed by the Engineer-in-Charge (EIC). All sizes as indicated in drawings. 50 Stackable stool type-’a’ Provide and assemble stackable stool using 25 mm thick BWR plywood (IS: 303 Grade of Century, Green Ply, Everest, or of equivalent make), 8 mm thick MS plate, 15 x 15 mm MS SHS and teakwood as per the sizes and shapes mentioned in the drawing. Fabricate legs by bending and appropriate welding of MS plate and Box sections, finishing with grinding and sanding. Apply 75-125µm functional powder-coating for a durable and scratch-resistant finish. Include teakwood buffers at the bottom of the supports and 25 mm thick plywood seating with 1 mm laminate (Century, Green Lam, Royal Touché, or of equivalent make), approved by the architect. Fix seating top and legs as per detail drawing. Edges will have melamine-polished 10 mm thick teakwood beading. Rubber gaskets are provided at the seating base for stacking. A sample will have to be made for approval before mass execution of the work. All materials and hardware, must be approved by the consultant as per the detailed specifications in the drawing and as directed by the Engineer-in-Charge (EIC). All sizes as indicated in drawings. 51 Stackable stool type-’b’ Provide and assemble stackable stool using 25 mm thick BWR plywood (IS: 303 Grade of Century, Green Ply, Everest, or of equivalent make), 8 mm thick MS plate, 15 x 15 mm MS SHS and teakwood as per the sizes and shapes mentioned in the drawing. Fabricate legs by bending and appropriate welding of MS plate and Box sections, finishing with grinding and sanding. Apply 75-125µm functional powder-coating for a durable and scratch-resistant finish. Include teakwood buffers at the bottom of the supports, as per detail shown in the drawing and 25 mm thick plywood seating with 1 mm laminate (Century, Green Lam, Royal Touché, or of equivalent make), approved by the architect. Fix seating top and legs as per detail drawing. Edges will have melamine-polished 10 mm thick teakwood beading. Rubber gaskets are provided at the seating base for stacking. A sample will have to be made for approval before mass execution of the work. All materials and hardware, must be approved by the consultant as per the detailed specifications in the drawing and as directed by the Engineer-in-Charge (EIC). All sizes as indicated in drawings. 52 Chair type - 1Provide and install a rocking chair made of glass-reinforced concrete of approved make as per sizes mentioned in the drawing. The chair’s seating, hand rest and backrest shall be moulded in glass-reinforced concrete as one single entity, with pigment approved by the architect. The chair features rounded edges and sealed surfaces for outdoor durability. The support structure consists of an 18° bended MS plate with three coats of synthetic enamel paint of approved shade over a coat of zinc chromate primer, and MS base plate with rubber strips at the bottom as per the detailed drawing. MS plate supports include a compression spring for easy movement.A sample will have to be made for approval before mass execution of the work. All materials, including adhesives and hardware, must be approved by the consultant as per the detailed specifications in the drawing and as directed by the Engineer-in-Charge (EIC).All sizes as indicated in drawings.Colour to be approved by the Architect. 53 Chair type - 2 roviding and placing in position ergonomic medium back revolving office chair with AN-70 breathable mesh backrest, single-lock synchro tilt mechanism with tilt tension adjustment, and adjustable lumbar support. Chair to have one-way heightadjustable armrests made of polypropylene, a cushioned seat with high-density PU foam upholstered in fabric, and a sturdy nylon five-star base with twin-wheel castors for smooth mobility. Suitable for long working hours with optimal comfort and posture support. Finish and color as approved by the architect. Make: Featherlite Versa or approved equivalent 54 Chair type -3 Supplying and placing in position ergonomic high back executive mesh chair with integrated headrest, made with IS 20D breathable mesh for enhanced airflow and seating comfort. Chair shall have a multi-lock synchro tilt mechanism allowing multiple reclining positions, and one-way (height adjustable) polypropylene armrests. Seat to be upholstered with high-density PU foam and durable fabric. The base shall be a five-star black nylon structure with twin-wheel castors for smooth movement. Suitable for executive cabins or prolonged work use with ergonomic support. Finish and color as per architect approval. Make: Featherlite Liberate or approved equivalent 55 Chair type -4Supplying and placing ergonomically designed chairs suitable for library and laboratory use, with cushioned seat and back upholstered in durable fabric/leatherette for user comfort during prolonged sitting. Chair to have a strong powdercoated metal sledge base ensuring stability, low maintenance, and non-scratch movement on floor surfaces. Ideal for educational and institutional settings, with available color options including Black, White, Red, Orange, and Green (as approved by architect). Make: Featherlite Loop Cushion or approved equivalent 56 Chair type -5Supplying and placing in position ergonomically designed low back mesh office chair with AC-60 breathable mesh backrest and fabric upholstered high-density cushion seat. The chair shall be fitted with a centre tilt mechanism for basic recline functionality and fixed polypropylene armrests. Base to be made of durable nylon with twin-wheel castors for smooth mobility. Suitable for visitor seating, conference rooms, or short-duration workstations. Finish and color as approved by the architect. Make: Featherlite Smart or approved equivalent 57 Bed_Girls rest room area Provide and install a bed, made of 25 mm thick BWR plywood (IS: 303 Grade of Century, Green Ply, Everest, or of equivalent make) for the bed top, 19 mm thick for supports and 12 mm thick for the bed back according to the sizes mentioned in the drawing. The external surfaces will have the 1 mm thick laminate (Century, Green Lam, Royal Touché or of equivalent make) and all the internal surface will have 0.8 mm thick off-white liner laminate, as approved by the architect.. Edges will have 2 mm PVC beading of Rehau polymers or equivalent make with similar shade of approved laminate. A sample must be approved before mass execution of the work. All materials, including of adhesive and hardware must be approved by the consultant as per the detailed specifications in the drawing and as directed by the Engineer-in-Charge (EIC). All sizes as indicated in drawings. 58 Pre – Primary school sofaProvide and install rectangular sitting furniture, as per sizes and shapes mentioned in the drawing, supported by teakwood frame supports. The top surface consists of a backing of 19 mm thick BWR plywood (IS: 303 Grade of Century, Green Ply, Everest, or equivalent make), covered with 75 mm foam. Sides will be covered with 25 mm thick foam with rounded edges on 12 mm thick BWP plywood (Green Ply, Everest or of equivalent make). The top and sides is to be finished with the selected fabric. The lower edge of the sitting area will be framed with 6 mm thick plywood for fabric fixation. All materials, including adhesives and hardware, must be approved by the consultant according to the detailed specifications in the drawing and as directed by the Engineer-in-Charge (EIC). All sizes as indicated in drawings. 59 HM Room Sofa / Conference room sofaSEAT FOAM : The seat is made up of PU foam in Density 28 ±2 kg/cu.mtr with an additional top layer of supersoft PU foam in Density 32 ± 2 kg/cu, upholstered with fabric or leatherette.BACK FOAM : The back is made up of PU foam in Density 28 ± 2 kg/cu. mtr with two additional top layer of supersoft foam of density 32±2 kg/cu. mtr, upholstered with fabric or leatherette.UNDERSTRUCTRE : Understructure is made up of 1.2±0.1 cm. thick hot pressed plywood [moisture resistance & termite proof as per IS:303] & pinewood of cross sections devoid of major knots & surface defects. 6 nos. per seat & 3.8mm Dia zigzag spring assembly is mounted over understructure for cushioning purpose.LEG ASSEMBLY : It is a welded Assembly made in Stainless steel (grade SS 202) tube & plate with plastic endcap.Width (W): 206.0 CM. Depth (D): 90.5 CM. Height (H): 85.5 CM. Seat Height (SH): 45.0 CM.Approved make: Godrej, bonton, Geeken or as specified in the list of approved furniture manufacture in the tender documentColour to be approved by the Architect. 60 Student Desk Type - 1Providing, supplying and placing of Desk cum Bench N Seater. Its size shall be 1040x1060x625. Desk-Top Panel-All panels are made from 18mm thick Pre-laminated twin board (E1/P2 GRADE) with PVC edge banding on all sides. The panels have corners rounded for safety usageUnderstructure: All side metal frames and cross connectors are made from combination of 25.4 x1.2 mm thick(approx. 18 SWG) Round ERW tubes ,31.8 x 1.2 mm thick(approx. 18 SWG) Round ERW tubes and 28.6 x 1.2 mm thick(approx. 18 SWG) Round ERW tubes(As per IS:7138) which are welded together. The Welded structures and cross connectors are coated with min. 45 micron thickness of epoxy polyester coating. Back supports which are provided at the rear back are made of 50.8 x 25.4 x 1.2 mm thick(approx. 18 SWG) rectangular ERW tubes(As per IS:7138).The tubes are coated with min. 45 micron thickness of epoxy polyester coating. The storage shelves are made from 0.6 mm thick MS sheet(As per IS:513) fixed below the desk top panel and are coated with min. 45 micron thickness of epoxy polyester coating. Hooks are provided on the vertical side frames on both sides of the desk for hanging bags/bottles. They are made from 2 mm thick MS sheet(As per IS:513) and are coated with min. 45 micron thickness of epoxy polyester coating.The understructure is assembled using M6 trilobular screws(As per DIN 7500)with Zn blue plating.Compact Laminate seat and back panels are assembled using M6 Countersunk Trilobular screws(as per DIN 7500) with Zn Black Plating (As per IS 1573:1986) Spacers Are provided on th top of round tubes for wooden panels fixing. They are made of PP Glass filled (30%)Plastic Caps made of PP copolymer(3530 Grade) are also provided on the rear frames adding more aesthetic value to the product. M6 high tensile TVS make bolt(Class 8.8) with glasss filled nylon level adjustors are provided at the bottom of understructure to take care of unevenness in floor with height adjustment of approx 15mm.Approved make: Godrej, bonton or as specified in the list of approved furniture manufacture in the tender documentColour to be approved by the Architect. 61 Student Desk Type - 2Providing, supplying and placing of Desk cum Bench N Seater. Its size shall be 1140x1095x710.Desk-Top Panel-All panels are made from 18mm thick Pre-laminated twin board (E1/P2 GRADE) with PVC edge banding on all sides. The panels have corners rounded for safety usageUnderstructure: All side metal frames and cross connectors are made from combination of 25.4 x1.2 mm thick(approx. 18 SWG) Round ERW tubes ,31.8 x 1.2 mm thick (approx. 18 SWG) Round ERW tubes and 28.6 x 1.2 mm thick(approx. 18 SWG) Round ERW tubes(As per IS:7138) which are welded together. The Welded structures and cross connectors are coated with min. 45 micron thickness of epoxy polyester coating. Back supports which are provided at the rear back are made of 50.8 x 25.4 x 1.2 mm thick(approx. 18 SWG) rectangular ERW tubes(As per IS:7138).The tubes are coated with min. 45 micron thickness of epoxy polyester coating. The storage shelves are made from 0.6 mm thick MS sheet(As per IS:513) fixed below the desk top panel and are coated with min. 45 micron thickness of epoxy polyester coating. Hooks are provided on the vertical side frames on both sides of the desk for hanging bags/bottles. They are made from 2 mm thick MS sheet(As per IS:513) and are coated with min. 45 micron thickness of epoxy polyester coating.The understructure is assembled using M6 trilobular screws(As per DIN 7500)with Zn blue plating.Compact Laminate seat and back panels are assembled using M6 Countersunk Trilobular screws(as per DIN 7500) with Zn Black Plating (As per IS 1573:1986)Spacers Are provided on th top of round tubes for wooden panels fixing. They are made of PP Glass filled (30%)Plastic Caps made of PP copolymer(3530 Grade) are also provided on the rear frames adding more aesthetic value to the product.M6 high tensile TVS make bolt(Class 8.8) with glasss filled nylon level adjustors are provided at the bottom of understructure to take care of unevenness in floor with height adjustment of approx 15mm.Approved make: Godrej, bonton or as specified in the list of approved furniture manufacture in the tender documentColour to be approved by the Architect. 62 Student Desk Type - 3Providing, supplying and placing of Desk cum Bench N Seater. Its size shall be 1240 x 1130 x 760.Desk-Top Panel-All panels are made from 18mm thick Pre-laminated twin board (E1/P2 GRADE) with PVC edge banding on all sides. The panels have corners rounded for safety usageUnderstructure: All side metal frames and cross connectors are made from combination of 25.4 x1.2 mm thick(approx. 18 SWG) Round ERW tubes ,31.8 x 1.2 mm thick (approx. 18 SWG) Round ERW tubes and 28.6 x 1.2 mm thick (approx. 18 SWG) Round ERW tubes(As per IS:7138) which are welded together. The Welded structures and cross connectors are coated with min. 45 micron thickness of epoxy polyester coating. Back supports which are provided at the rear back are made of 50.8 x 25.4 x 1.2 mm thick (approx. 18 SWG) rectangular ERW tubes (As per IS:7138). The tubes are coated with min. 45 micron thickness of epoxy polyester coating. The storage shelves are made from 0.6 mm thick MS sheet(As per IS:513) fixed below the desk top panel and are coated with min. 45 micron thickness of epoxy polyester coating. Hooks are provided on the vertical side frames on both sides of the desk for hanging bags/bottles. They are made from 2 mm thick MS sheet(As per IS:513) and are coated with min. 45 micron thickness of epoxy polyester coating.The understructure is assembled using M6 trilobular screws(As per DIN 7500)with Zn blue plating.Compact Laminate seat and back panels are assembled using M6 Countersunk Trilobular screws(as per DIN 7500) with Zn Black Plating (As per IS 1573:1986)Spacers Are provided on the top of round tubes for wooden panels fixing. They are made of PP Glass filled (30%)Plastic Caps made of PP copolymer(3530 Grade) are also provided on the rear frames adding more aesthetic value to the product.M6 high tensile TVS make bolt(Class 8.8) with glass filled nylon level adjustors are provided at the bottom of understructure to take care of unevenness in floor with height adjustment of approx. 15mm.Approved make: Godrej, bonbon or as specified in the list of approved furniture manufacture in the tender documentColour to be approved by the Architect. 63 EPDM flooring Multicolour EPDM flooring for Pre school classroom. The interlocking tile to be 500 mm x 500 mm. The thickness of EPDM tile to be 25mm & tensile failure stress of 17MPa. Laying of tile with thin coat of water based adhesive. The sample to be approved by the Engineer in Charge (EIC). 64 RugProviding of the rug for HM rooms of the size 2000 x 3000 and placed as per the location provided by the architect. The rug should have vinyl rubber bottom. The sample to be approved by the architect. 65 Anti-Skid Door MatProviding of the door/rubber mat for boys/girls/handicap toilet placed as per the location provided by the architect. The mat should have anti-skid bottom. The sample to be approved by the architect 66 MDM Roll carpetHand woven reversible 100% natural cotton striped / roll carpet (Blue - Border, 600mm wide x 5m roll), washable, fade resistant, durable and easily foldable. 67 Carpet tile flooringProviding and laying Flotex floor covering (or approved equivalent), a high-performance textile flooring solution suitable for music rooms in schools. The flooring shall be made of dense nylon 6.6 fibers electrostatically flocked onto a waterproof PVC backing, offering excellent durability, acoustic absorption, slip resistance, and ease of maintenance. Flotex shall combine the resilience of a resilient floor with the comfort and acoustic benefits of a textile floor. The material shall be anti-microbial, allergy-friendly, stain-resistant, and suitable for high foot traffic educational areas. Flooring shall be laid with recommended adhesive on a properly prepared subfloor, ensuring neat joints and smooth finish. Color/Pattern: As per architect’s selection 68 Aluminium galvanized wooden finish ceilingProviding and fixing aluminium galvanized ceiling panels in 100mm / 150mm / 200mm width, with wood grain finish (teak/oak/walnut or approved), fixed on concealed GI/aluminium suspension system with all necessary accessories (trims, hangers, fasteners). Panels shall be pre-coated/powder-coated, rust-proof, and suitable for indoor ceiling applications. 69 Acoustic Wall panellingProvide and install acoustic panels as per approved design and sample by Architect. The panels shall feature fabric-wrapped high- density glass wool/wood wool/ combinations of foam and fabric/basophilic elements like cork and moss measuring 600 x 600/1200mm with a thickness of 25-50mm. Fixing of the panelling should be approved by the Engineer-in-Charge (EIC). 70 Ceiling panellingProvide and install medium-density fibreboard(MDF) acoustic panels for slab and wall applications. The perforated panels, manufactured from high-quality MDF with a density of 750-850 kg/cubic meter and thickness of 1 mm ( ½” to 1”), shall have a sound absorption coefficient of 0.5-0.8 and a noise reduction coefficient of 0.55 for a 3.12 sq.m area. The panels measure 190mm x 1190mm with 6mm perforation holes and shall be fixed using aluminium channels and hold clips. The sample must be approved by the Engineer-in-Charge (EIC). 71 Acoustic Baffle and cloud CeilingProvide Rockwool rigid baffles and clouds, manufactured from high-density rock wool, with specifications including: 1200 x 1200mm size, 40mm thickness and a Noise Reduction coefficient (NRC) of 0.9. The baffles and clouds shall be wrapped in a textured finish fabric, offering various colour and fabric options. Fixing shall be done using anchor bolts to secure the baffles to the slab and suspension system for the clouds. Fixing of the panelling should be approved by the Engineer-in-Charge (EIC). 72 Painting work on MS FabricationApply painting work on MS fabrication, including PU coating, touch-ups and surface rubbing to rectify poor finishes. This involves two or more coats of Deluxe Multi Surface Paint to achieve an even shade, applying two or more coats (@0.90 litter/10sqm) over a primer undercoat (@0.80 litter/10 sqm) to achieve an even shade on existing steel columns, following thorough surface cleaning, using materials from approved brands and manufacturers. 73 Roller BlindsProviding and fixing roller blinds with fabric of approved shade and design, mounted on heavy-dutyaluminum roller tube with powder-coated finish. The fabric shall be UV-resistant, dust-repellent, and fade-proof, suitable for interior applications,with smooth rolling action using a chain and clutch mechanism for manual operation. The blinds shall be fixed with appropriate MS/Aluminium brackets, end caps, and fittings for wall or ceiling mounting, as per site condition. Edges of the fabric shall be heat sealed or hemmed to prevent fraying.Material: Polyester fabric / Sunscreen / Blackout fabric (as specified)Color/Shade: As approved by architect 74 Dustbin Type - aProviding of the black finished stainless steel perforated open top waste bin of the size 175 x 250 for classroom, lab, toilets and girls rest room as per the location provided by the architect. The waste bin to be made of NON MAGNETIC SS 200 SERIES Thickness - 0.4 mm, Metallic Elegant look. The waste bin to have anti-slip base. The sample to be approved by the architect. The items shall be in working condition. Approved Make :IKEA, Mofna Industries pvt. ltd. 75 MirrorProviding and fixing bevelled edge mirror of required size and shape as per architectural drawings, made from 5mm thick high-quality float glass with polished bevelled edges (bevel width approx. 18–25mm). The mirror shall be fixed to the wall using concealed fixtures, stainless steel studs/spacers, or adhesive as per site condition, ensuring a secure and flush installation. All necessary fittings and supports shall be included in the scope. Approved Make: Saint-Gobain, Modiguard, or equivalent 76 Toilet paper holdersProviding and fixing wall-mounted toilet paper holder made of corrosion-resistant stainless steel with brushed/matte finish. The design shall be minimal and contemporary, suitable for modern toilet interiors. Holder to be fixed using concealed fasteners for a clean look. All necessary screws, wall plugs, and installation accessories to be included. Suitable for use in residential, commercial, or institutional toilets. Approved Make: IKEA (BROGRUND), Jaquar, Kohler, or equivalent 77 Soap Dispensers and dispenser holderProviding and fixing wall-mounted liquid soap dispenser complete with stainless steel holder, suitable for residential, commercial, or institutional toilets. The dispenser container shall be made of durable acrylic or frosted glass with a hand-operated pump mechanism. The holder shall be fabricated from corrosion-resistant stainless steel (SS 304 or equivalent) with a brushed finish, designed to securely support the dispenser. The unit shall be installed with concealed fasteners and shall include all necessary mounting hardware and accessories. Approved Make: Jaquar, Kohler, or equivalent 78 Wall clockProviding and fixing wall-mounted round analog clock of 380mm diameter (38 cm), with a clear, easy-toreaddial featuring bold hour and minute markings. The clock shall have a durable plastic frame and a front cover made of glass/acrylic,equipped with a silent quartz movement mechanism for smooth and noise-free operation. Battery-operated and suitable for classrooms,offices, or institutional spaces. Color and design as approved by architect. Approved Make: IKEA (Tagged model), Ajanta, or equivalent 79 Type - 1 SignagesSupply & fixing ONE 100mm in height Stainless Steel Cut-out (5mm Thick), displaying classroom number, name of room, etc., complete matter will be Laser Cut from natural SS with Matt Finish & Matt Lacquer, fitting directly on wall with 3M Double-Gum tape 80 Type - 2 SignageSupply & fixing reverseLit channel letter, displayingschool name as per your design in which letter will be 450mm in height, complete with all accessories i.e. 1.5” emboss Stainless Steel Matt Finish (0.8mm Thick) Letters with with Groove cut 25mm Thick Acrylic Letters assembled behind SS Letter, LED’s (Warm White or White), SMPS, L.T.Wire for inside Wiring etc. 81 Type - 3 SignageProviding and fixing of the evacuation diagram, made on acrylic sheet with eco-solvent print. The evacuation diagram to be of the size 297 x 210mm and made from 5mm thick acrylic sheet. The diagram to be printed on the sheet with the eco-solvent print. The diagram to be fixed on the surface with 3M adhesive tape as per the location provided by the architect. Diagram for printing in required format shall be provided by architect. 82 S.S. RailingProviding and fixing stainless steel (Grade 316) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in charge. (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) and as directed by EIC. The rate to include all scaffolding and hoisting charges. 83 100mm foam mattressProviding of the 100mm thick foam mattress of the size 850 x 1700 as per the location provided by the architect. The foam mattress to include the layer of PU foam, a layer of Resitec foam, a layer of double layered quilting foam and a layer of knitted fabric as the top most layer. The sample to be approved by the architect. Approved Make: Sleepwell or equivalent 84 Notice Board: Providing and fixing wall-mounted notice board of size 900mm × 600mm (3 feet × 2 feet), constructedwith 12mm thick soft board mounted on 6mm thick BWR Grade plywood conforming to IS:303 (Century Ply or equivalent). The board surfaceshall be covered with fabric/felt cloth in approved color for pin-up use. The notice board shall be enclosed in a polished hardwood frame andfitted with a hinged front-opening 4mm thick clear glass shutter, complete with brass/SS hinges, magnetic catch, and handle. Suitable forsecure display of notices in educational or institutional spaces. 85 Soft BoardProviding and fixing pin-up soft board of size 2400mm × 1200mm (8 feet × 4 feet), comprising 12mmthick soft board mounted on 6mm thick BWR Grade plywood of IS:303 Century Ply or equivalent. The board surface shall be covered withfabric/felt cloth in approved shade, suitable for classroom and lab use. The board shall be finished with an anodized aluminium frame withmitred corners, fixed flush to wall with concealed fasteners and necessary supports. 86 Smart TVSITC of 65 inch Smart Interactive display true 4K UltraHD (3,840 × 2,160) resolution for outstanding details and stunning visuals. It should be IPS Panel with 3mm-thick toughened glass for added protection against scratches or screen damage, Anti-Glare + Anti-Fingerprint + Antimicrobial. with Pen including all required wall mounting stand and all accessoriesIt must equip front bezel USB-A, USB-C ports for quick connection to USB keyboards/mice, memory drives and data, High-speed Wi-Fi 6 connection, Bluetooth 5.2, Dual RJ45 ports. Brightness 400 cd/m² or above. 20-point touch, 18W x 2 (Stereo), OS Android v13 or above, Speakers: 18W x 2 (Stereo), 32GB Internal memory + 4GB RAMPreloaded software like whiteboard, screen share, screen annotation and recording tools, centralized device management through Remote Manager Cloud or Windows software, Browser, App Store, Media Player. Screen lock, Dual Network Environment. OPS: Intel® i5 Processor Iris® Xe Graphics, 8GB RAM, 256 GB name SSD, 3 nos. USB 3.0 ports,1 HDMI port, 1 DP interface,1 Type-C port, Support dual channel memory, Wi-Fi IEEE 802.11. Windows 11 Pro Licence. ISO 27001 Certified. 3 years warranty of Samsung, LG Panasonic, DELTA 87 Movable Softboard: Suppling, fabricating and installing movable soft board with anodized aluminium frame and high density 12mm thick softboard surface finished with approved fabric of Red/blue/brown/white colour. The Board shall be mounted on smooth castor wheels with locking mechanism for stability ensuring durability and ease of mobility. Dimension 2400 x 1200 with precise fitting and smooth edge for safety. 88 Metal Box Kitchen StorageProviding and supplying grain storage container fabricated from galvanized iron (GI) sheet, suitable foruse in school kitchen store under the Mid-Day Meal scheme. The container shall be made from 22–24 gauge GI sheet, rust-resistant and foodsafe, with a capacity to hold up to 100 kg of food grains (such as rice or wheat). The container shall be of cylindrical or rectangular shape (as approved), with a tight-fitting hinged or lift-off lid to protect contents from moisture, pests, and contamination. All edges shall be folded or crimped for safety and strength. 89 Metal Box Kitchen StorageProviding and supplying grain storage container fabricated from galvanized iron (GI) sheet, suitable foruse in school kitchen store under the Mid-Day Meal scheme. The container shall be made from 22–24 gauge GI sheet, rust-resistant and foodsafe, with a capacity to hold up to 20 kg of food grains (such as rice or wheat). The container shall be of cylindrical or rectangular shape (as approved), with a tight-fitting hinged or lift-off lid to protect contents from moisture, pests, and contamination. All edges shall be folded or crimped for safety and strength. 90 MDM Storage RacksProviding and placing in position storage rack fabricated from mild steel (MS) sections, suitable for the store area of a school kitchen under the Mid-Day Meal scheme. The rack shall be free-standing, made with MS tubular vertical supports and horizontal bracing, and shelves fabricated from 24-gauge (approx. 0.6mm thick) MS sheet, fixed or adjustable as per site condition. The entire structure shall be degreased, pre-treated, and finished with oven-baked powder coating of minimum 50–60 microns in approved color. The rack shall have a minimum of four shelves, with sufficient load-bearing capacity to store grains, containers, and kitchen supplies. All edges shall be smooth and safe to handle.Material: Mild Steel frame with 24-gauge MS sheet shelvesFinish: Powder-coated (min. 50–60 microns) in approved shadeSize: As per drawing / approx. 5–6 height, 3–4 length, 18–24 depth 91 Dish RackProviding and fixing stainless steel dish rack made of SS 304 grade material, designed specifically for use in school kitchens for mid-day meal purposes. The rack shall be multi-tiered to accommodate large plates, glasses, and utensils, with proper drainage and a detachable drip tray to ensure hygiene. The design will include durable, corrosion-resistant stainless steel with smooth, easy-to-clean surfaces and rounded edges to prevent damage to the dishes. The rack shall be wall-mounted or free-standing based on the kitchen layout and shall include all necessary brackets, screws, and hardware for secure installation. 92 WoodProviding and supplying seasoned Indian Teak Wood of approved quality and grade (CP/MP or equivalent), free from warping, cracks, knots, or other defects, with uniform grain and texture. The wood shall be properly kiln/air dried with a moisture content not exceeding 12–14%, suitable for use in premium interior applications such as furniture, panelling, door frames, or customized joinery works. Rate to include loading, unloading, handling, and stacking at site. 93 Wall Table (VB_Bio) 7280L X 770D X 900HFloor Based Cabinet with Metal Skirting powder coated withpure epoxy of thickness 40-50 microns. Worktop is 19mm (+/- 2mm) thickJet Black Granite construction. Considered with 6 nos of 600mm wide 2 shutter 1 drawer units with 5nos of 600mm widemiddle leg space and 1 no of 600mm wide corner leg space. Master uprights, uprights and height adjustable reagent racks,8 nos of one way LPG gas valves and 5 nos of stools are considered inthe same table. 12 nos of 6 module plate with 24 nos of 6/16A switch and sockets also maintained in the layout. Approved make: Godrej or as specified in the list of approved furniture manufacture in the tender document Colour to be approved by the Architect. 94 Island Table (VB_Bio)4880L X 1540D X 900HFloor Based Cabinet with Metal Skirting powder coated withpure epoxy of thickness 40-50 microns.Worktop is 19mm (+/- 2mm) thickJet Black Granite construction.Considered with 8 nos of 600mm wide 2 shutter 1 drawer units with 6nos of 600mm widemiddle legspace and 2 no of 600mm wide Corner legspace. Master uprights, uprights and height adjustable reagent racks, 4 nos of two way lpg valves and8 nos of stools are considered inthe same table. 14 nos of 6 module plate with 28 nos of 6/16A switch and sockets also maintained in the layout. Approved make: Godrej or as specified in the list of approved furniture manufacture in the tender document Colour to be approved by the Architect. 95 Wall Table (VB_Bio)7280L X 770D X 900HFloor Based Cabinet with Metal Skirting powder coated withpure epoxy of thickness 40-50 microns.Worktop is 19mm (+/- 2mm) thickJet Black Granite construction. Considered with 6 nos of 600mm wide 2 shutter 1 drawer units with 5nos of 600mm widemiddle legspace and 1 no of 600mm wide Corner legspace. Master uprights, uprights and height adjustable reagent racks ,6nos of one way lpg gas valves and 6 nos of stools are considered inthe same table. 12 nos of 6 module plate with 24 nos of 6/16A switch and sockets also maintained in the layout. Approved make: Godrej or as specified in the list of approved furniture manufacture in the tender document Colour to be approved by the Architect. 96 MS Apparatus Storage Cabinet (VB_Bio)900W X560D X 2100HMS Apparatus Storage Cabinet with top cover plate. Approved make: Godrej or as specified in the list of approved furniture manufacture in the tender document Colour to be approved by the Architect. 97 Wall Table (VB_Physics)7280L X 770D X 900HFloor Based Cabinet with Metal Skirting powder coated withpure epoxy of thickness 40-50 microns.Worktop is 19mm (+/- 2mm) thickJet Black Granite construction.Considered with 6 nos of 600mm wide 2 shutter 1 drawer units with 5nos of 600mm widemiddle legspace and 1 no of 600mm wide Corner legspace. Master uprights, and electrical trunkings and 6 nos of stools are considered inthe same table. 17 nos of 6 module plate with 34 nos of 6/16A switch and sockets also maintained in the layout. Approved make: Godrej or as specified in the list of approved furniture manufacture in the tender document Colour to be approved by the Architect. 98 Island Table(VB_Physics)4880L X 1540D X 900HFloor Based Cabinet with Metal Skirting powder coated withpure epoxy of thickness 40-50 microns.Worktop is 19mm (+/- 2mm) thickJet Black Granite construction.Considered with 8 nos of 600mm wide 2 shutter 1 drawer units with 6nos of 600mm widemiddle legspace and 2 no of 600mm wide Corner legspace. Master uprights,electrical trunkings and8 nos of stools are considered inthe same table. 22 nos of 6 module plate with 44 nos of 6/16A switch and sockets also maintained in the layout. Approved make: Godrej or as specified in the list of approved furniture manufacture in the tender document Colour to be approved by the Architect. 99 Wall Table(VB_Physics)7280L X 770D X 900HFloor Based Cabinet with Metal Skirting powder coated withpure epoxy of thickness 40-50 microns. Worktop is 19mm (+/- 2mm) thickJet Black Granite construction. Considered with 6 nos of 600mm wide 2 shutter 1 drawer units with 5nos of 600mm widemiddle legspace and 1 no of 600mm wide Corner legspace. Master uprights, and electrical trunkings and 6 nos of stools are considered inthe same table. 17 nos of 6 module plate with 34 nos of 6/16A switch and sockets also maintained in the layout. Approved make: Godrej or as specified in the list of approved furniture manufacture in the tender document Colour to be approved by the Architect. 100 Full Height Acid/Corrosive Storage Cabinet(VB_Physics)1000 x 1500 x 486Full Height Acid/Corrosive Storage Cabinet (Resilience). Approved make: Godrej or as specified in the list of approved furniture manufacture in the tender document Colour to be approved by the Architect. 101 MS Apparatus Storage Cabinet(VB_Physics)900W X560D X 2100HMS Apparatus Storage Cabinet with top cover plate. Approved make: Godrej or as specified in the list of approved furniture manufacture in the tender document Colour to be approved by the Architect. 102 Wall Table(VB_Chemistry)7280L X 770D X 900HFloor Based Cabinet with Metal Skirting powder coated withpure epoxy of thickness 40-50 microns.Worktop is 19mm (+/- 2mm) thickJet Black Granite construction.Considered with 6 nos of 600mm wide 2 shutter 1 drawer units with 5nos of 600mm widemiddle legspace and 1 no of 600mm wide Corner legspace. Master uprights, uprights and height adjustable reagent racks, 6 nos of one way lpg gas valves and 5 nos of stools are considered inthe same table. 12 nos of 6 module plate with 24 nos of 6/16A switch and sockets also maintained in the layout. Approved make: Godrej or as specified in the list of approved furniture manufacture in the tender document Colour to be approved by the Architect. 103 Island Table (VB_Chemistry)4880L X 1540D X 900HFloor Based Cabinet with Metal Skirting powder coated withpure epoxy of thickness 40-50 microns.Worktop is 19mm (+/- 2mm) thickJet Black Granite construction.Considered with 8 nos of 600mm wide 2 shutter 1 drawer units with 6nos of 600mm widemiddle legspace and 2 no of 600mm wide Corner legspace. Master uprights, uprights and height adjustable reagent racks, 4 nos of two way lpg gas valves and8 nos of stools are considered inthe same table. 14 nos of 6 module plate with 28 nos of 6/16A switch and sockets also maintained in the layout. Approved make: Godrej or as specified in the list of approved furniture manufacture in the tender document Colour to be approved by the Architect. 104 Wall Table (VB_Chemistry)7280L X 770D X 900HFloor Based Cabinet with Metal Skirting powder coated withpure epoxy of thickness 40-50 microns.Worktop is 19mm (+/- 2mm) thickJet Black Granite construction.Considered with 6 nos of 600mm wide 2 shutter 1 drawer units with 5nos of 600mm widemiddle legspace and 1 no of 600mm wide Corner legspace. Master uprights, uprights and height adjustable reagent racks, 6 nos of one way lpg gas valves and 5 nos of stools are considered inthe same table. 12 nos of 6 module plate with 24 nos of 6/16A switch and sockets also maintained in the layout. Approved make: Godrej or as specified in the list of approved furniture manufacture in the tender document Colour to be approved by the Architect. 105 MS Apparatus Storage Cabinet(VB_Chemistry)900W X560D X 2100HMS Apparatus Storage Cabinet with top cover plate. Approved make: Godrej or as specified in the list of approved furniture manufacture in the tender document Colour to be approved by the Architect. 106 Wall Table (VD_Bio)6830L X 770D X 900HFloor Based Cabinet with Metal Skirting powder coated withpure epoxy of thickness 40-50 microns.Worktop is 19mm (+/- 2mm) thickJet Black Granite construction.Considered3 nos of 750mm wide 2 shutter sink unit including 3 no of PP sinks of size 560x355 with 3 water faucets, 2nos of 1500mm widemiddle legspace and 2 no of 750mm wide Corner legspace. Master uprights, uprights and height adjustable reagent racks, 4 nos of one way lpg gas valves and 6 nos of stools are considered inthe same table. 4 nos of 6 module plate with 8 nos of 6/16A switch and sockets also maintained in the layout. Approved make: Godrej or as specified in the list of approved furniture manufacture in the tender document Colour to be approved by the Architect. 107 Island Table (VD_Bio)4880L X 1540D X 900HFloor Based Cabinet with Metal Skirting powder coated withpure epoxy of thickness 40-50 microns.Worktop is 19mm (+/- 2mm) thickJet Black Granite construction.Considered with 4 nos of 750mm wide 2 shutter sink unit including 4 no of PP sink of size 560x355 with 4 water faucet, 2nos of 1500mm widemiddle legspace and 4 no of 750mm wide Corner legspace.Master uprights, uprights and height adjustable reagent racks, 3 nos of two way lpg gas valves and8 nos of stools are considered inthe same table,4 nos of 6 module plate with 8 nos of 6/16A switch and sockets also maintained in the layout. Approved make: Godrej or as specified in the list of approved furniture manufacture in the tender document Colour to be approved by the Architect. 108 Wall Table (VD_Bio) 6830L X 770D X 900HFloor Based Cabinet with Metal Skirting powder coated withpure epoxy of thickness 40-50 microns.Worktop is 19mm (+/- 2mm) thickJet Black Granite construction.Considered3 nos of 750mm wide 2 shutter sink unit including 3 no of PP sinks of size 560x355 with 3 water faucets, 2nos of 1500mm widemiddle legspace and 2 no of 750mm wide Corner legspace.Master uprights, uprights and height adjustable reagent racks, 4 nos of one way lpg gas valves and 6 nos of stools are considered inthe same table. 4 nos of 6 module plate with 8 nos of 6/16A switch and sockets also maintained in the layout. Approved make: Godrej or as specified in the list of approved furniture manufacture in the tender document Colour to be approved by the Architect. 109 MS Apparatus Storage Cabinet (VD_Bio)900W X560D X 2100HMS Apparatus Storage Cabinet with top cover plate. Approved make: Godrej or as specified in the list of approved furniture manufacture in the tender document Colour to be approved by the Architect. 110 Wall Table (VD_Physics)7280L X 770D X 900HFloor Based Cabinet with Metal Skirting powder coated withpure epoxy of thickness 40-50 microns.Worktop is 19mm (+/- 2mm) thickJet Black Granite construction. Considered with 6 nos of 600mm wide 2 shutter 1 drawer units with 5nos of 600mm widemiddle legspace and 1 no of 600mm wide Corner legspace. Master uprights, electrical trunkings and 6 nos of stools are considered inthe same table. 12 nos of 6 module plate with 24 nos of 6/16A switch and sockets also maintained in the layout. Approved make: Godrej or as specified in the list of approved furniture manufacture in the tender document Colour to be approved by the Architect. 111 Island Table(VD_Physics)4880L X 1540D X 900H Floor Based Cabinet with Metal Skirting powder coated withpure epoxy of thickness 40-50 microns.Worktop is 19mm (+/- 2mm) thickJet Black Granite construction. Considered with 8 nos of 600mm wide 2 shutter 1 drawer units with 6nos of 600mm widemiddle legspace and 2 no of 600mm wide Corner legspace. Master uprights,electrical trunkings and8 nos of stools are considered inthe same table. 22 nos of 6 module plate with 44 nos of 6/16A switch and sockets also maintained in the layout. Approved make: Godrej or as specified in the list of approved furniture manufacture in the tender document Colour to be approved by the Architect. 112 Wall Table(VD_Physics)7280L X 770D X 900HFloor Based Cabinet with Metal Skirting powder coated withpure epoxy of thickness 40-50 microns.Worktop is 19mm (+/- 2mm) thickJet Black Granite construction.Considered with 6 nos of 600mm wide 2 shutter 1 drawer units with 5nos of 600mm widemiddle legspace and 1 no of 600mm wide Corner legspace. Master uprights, electrical trunkings and 6 nos of stools are considered inthe same table. 12 nos of 6 module plate with 24 nos of 6/16A switch and sockets also maintained in the layout. Approved make: Godrej or as specified in the list of approved furniture manufacture in the tender document Colour to be approved by the Architect. 113 Full Height Acid/Corrosive Storage Cabinet(VD_Physics)1000 x 1500 x 486 Full Height Acid/Corrosive Storage Cabinet (Resilience). Approved make: Godrej or as specified in the list of approved furniture manufacture in the tender document Colour to be approved by the Architect. 114 MS Apparatus Storage Cabinet(VD_Physics)900W X560D X 2100HMS Apparatus Storage Cabinet with top cover plat. Approved make: Godrej or as specified in the list of approved furniture manufacture in the tender document Colour to be approved by the Architect. 115 Wall Table(VD_Chemistry)6830L X 770D X 900HFloor Based Cabinet with Metal Skirting powder coated withpure epoxy of thickness 40-50 microns.Worktop is 19mm (+/- 2mm) thickJet Black Granite construction.Considered3 nos of 750mm wide 2 shutter sink unit including 3 no of PP sinks of size 560x355 with 3 water faucets, 2nos of 1500mm widemiddle legspace and 2 no of 750mm wide Corner legspace. Master uprights, uprights and height adjustable reagent racks, 4 nos of one way lpg gas valves and 6 nos of stools are considered inthe same table. 4 nos of 6 module plate with 8 nos of 6/16A switch and sockets also maintained in the layout. Approved make: Godrej or as specified in the list of approved furniture manufacture in the tender document Colour to be approved by the Architect. 116 Island Table (VD_Chemistry)4880L X 1540D X 900HFloor Based Cabinet with Metal Skirting powder coated withpure epoxy of thickness 40-50 microns.Worktop is 19mm (+/- 2mm) thickJet Black Granite construction.Considered with 4 nos of 750mm wide 2 shutter sink unit including 4 no of PP sink of size 560x355 with 4 water faucet, 2nos of 1500mm widemiddle legspace and 4 no of 750mm wide Corner legspace.Master uprights, uprights and height adjustable reagent racks, 3 nos of two way lpg gas valves and8 nos of stools are considered inthe same table,4 nos of 6 module plate with 8 nos of 6/16A switch and sockets also maintained in the layout. Approved make: Godrej or as specified in the list of approved furniture manufacture in the tender document Colour to be approved by the Architect. 117 Wall Table (VD_Chemistry)6830L X 770D X 900HFloor Based Cabinet with Metal Skirting powder coated withpure epoxy of thickness 40-50 microns.Worktop is 19mm (+/- 2mm) thickJet Black Granite construction.Considered3 nos of 750mm wide 2 shutter sink unit including 3 no of PP sinks of size 560x355 with 3 water faucets, 2nos of 1500mm widemiddle legspace and 2 no of 750mm wide Corner legspace. Master uprights, uprights and height adjustable reagent racks, 4 nos of one way lpg gas valves and 6 nos of stools are considered inthe same table. 4 nos of 6 module plate with 8 nos of 6/16A switch and sockets also maintained in the layout. Approved make: Godrej or as specified in the list of approved furniture manufacture in the tender document Colour to be approved by the Architect. 118 MS Apparatus Storage Cabinet(VD_Chemistry)900W X560D X 2100HMS Apparatus Storage Cabinet with top cover plat.Approved make: Godrej or as specified in the list of approved furniture manufacture in the tender documentColour to be approved by the Architect. 119 Lab Stool/ Drg. Stool- Specification: Size:H:710, Seat:H:550, D:300,Under Structure:-Made up of MS cold rolled close annealed,18G tube. Topmade of 18mm thick pre-laminated particle board. Side edges covered with teak wood beading duly polished. All steel components are epoxy powder coated followed by seven tanks anti corrosion treatment of surface. Approved make: Godrej, bonbon or as specified in the list of approved furniture manufacture in the tender documentColour to be approved by the Architect. 120 Kesariyaji Green MarbleProviding and laying kesariyaji green marble, 18-20 mm thick machine cut and polished to a smooth finish. Marble laid over a 1:4 cement mortar bed with white cement slurry, ensuring proper alignments and vein continuity. Joints to be filled with matching epoxy joint. 121 Wooden Laminate FlooringSupply and instakkation of 8mm thick wooden laminate flooring with a screatch-resistant, anti slip surface and click-lock joint system. Incudes foam/felt underlayment for sounfproofing and moisture resistance, skirting, trims and post-installation cleaning.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 5
Daman And Diu View Result →
11.
Power #10775882 Price Bid
Rate Contract for procurement/Installation charges of various materials required for maintenance of 33/11 KV Receiving stations for upkeeping of power supply of Receiving stations under jurisdiction of STD Pulwama for the year 2025-26 or till next Rate Contract.- 1 Dismantalling of 2 11KV VCB Panel complete 3 33KV C&R Panel complete 4 33KV VCB / MOCB complete 5 Installation,testing and commissioningof Switchgear System complete(material to be provided by the department) 6 11KV VCB Panel complete 7 33KV C&R Panel complete 8 33KV VCBcomplete 9 Supply of 11 kV VCB Panel Board 12 kV, 1250A, 25 KA,(Incommer) as per Technical Specifications of REC Std 10 Supply of 11 kV VCB Panel Board 12 kV, 1250A, 25 KA,(Outgoing) as per Technical Specifications of REC Std 11 Supply of 33 kV VCB(36 kV, 1250A, 26.2 kA, Outdoor Type) as per Technical Specifications of REC Std 12 Supply of 33 kV C&R Panel with nemurical Relays with Differential Relay ( IEC 61850), Voltmeter, Ammeter, Annunciation Windows with annunciation relays, 3-phase Tri-vector meter -5 Amps, DLMS Compliant as per Technical Specifications of REC Std 13 Supply of 33 kV C&R Panel with nemurical Relays with out Differential Relay ( IEC 61850), Voltmeter, Ammeter, Annunciation Windows with annunciation relays, 3-phase Tri-vector meter -5 Amps, DLMS Compliant as per Technical Specifications of REC Std 14 Supply of fresh 11KV C.T by way of Replacement of Damaged/Burnt Out/low size 11 KV C.T of same ratio,type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for following 11KV VCB with ratio 800-400/5-5-5A, 600-300, 400-200, 100-50 15 Alsthommake 16 Easun Reyroll Make 17 Vijay Make 18 Sudhir Make 19 Electric Field 20 Crompton Greeves 21 Allind 22 ABB Make 23 Pascal Make 24 Hartek Make 25 Supply of 33KV Hand Gloves of Crystal or equivalent make conforming to IS: 4770, 13774 26 Installation,testing and commissioning of fresh 11KV C.T by way of Replacement of Damaged/Burnt Out 11 KV C.T of same ratio,type,make and class already installed in panel (material to be provided by the department) (for 11KV VCB panels) 27 Supply of 11KV P.T by way of Replacement of Damaged/Burnt Out 11 KV P.T of same ratio,type,make and class already installed in panel confirming to IEC 60044-1-2000 standards (for 11KV VCB panels) 28 Installation,testing and commissioning of fresh 11KV P.T by way of Replacement of Damaged/Burnt Out 11 KV P.T of same ratio,type,make and class already installed in panel (material to be provided by the department) (for 11KV VCB panel) 29 Providing offresh male contact (set of 06 Pcs) of following 11KV VCB by way of Replacement of Damaged/Burnt Outmale contact setof same composition,type,make and class already installed in 11KV VCB panel 30 Alsthommake 31 Easun Reyroll Make 32 Vijay Make 33 Sudhir Make 34 Electric Field 35 Crompton Greeves 36 Allind 37 ABB Make 38 Providing offresh male contact (set of 06 Pcs) of following 11KV VCB by way of Replacement of Damaged/Burnt Outmale contact setof same composition,type,make and class already installed in 11KV VCB panel 39 Alsthommake 40 Easun Reyroll Make 41 Vijay Make 42 Sudhir Make 43 Electric Field 44 Crompton Greeves 45 Allind 46 ABB Make 47 Providing of 11KV Vacuum Interruptor by way of Replacement of Damaged/Burnt Out 11KV Vacuum Interruptor of same composition,type,make as already installed in 11KV VCB panel (1250amps) of following make 48 Alsthommake 49 Easun Reyroll Make 50 Vijay Make 51 Sudhir Make 52 Electric Field 53 Crompton Greeves 54 Allind 55 ABB Make 56 Pascal Make 57 Hartek Make 58 Fixing of fresh 11KV Vacuum Interruptor by way of Replacement of Damaged/Burnt Out 11KV Vacuum Interruptor of same composition,type,make already installed in 11kv vcb panel (material to be provided by the department) 59 Supply of Numerical/Digital Relayby way of Replacement of Damaged/Burnt of same ratio(A.C &D.C),type,make and class already installed in panel.All relays shall conform to the requirements of IS:3231/IEC-60255 and IEC-61850 of (MIT113 ER / Ashida 141A) Operating Voltage 30-36Volts 60 Fixing , testing and commissioning of Numerical/Digital Relay (MIT113 / Ashida 141A) by way of Replacement of Damaged/Burnt of same ratio(A.C &D.C),type,make and class already installed in 11KV VCB panel.(material to be provieded by the department) 61 Supply of Panel Insulator (Supporting Insulator for Bus) for 11KV VCB panels like Easun Reyroll, Allind, Alsthom, Crompton Greeves, Electric field or the like 62 Rectification,Re-Alignment,setting right the electricalsection of 11KV Breakers(11KV VCB panel) 63 Rectification,Re-Alignment,setting right the mechnicalsection of 11KV Breakers(11KV VCB Panel) 64 Rectification,Re-Alignment,setting right the electrical section of 33KV C&R panel 65 Rectification,re-alignment,setting right the mechnical section of 33KV VCB 66 Rectification,re-alignment,setting right the mechnical section of 33KV MOCB 67 Replacement of damaged clamps (A.A) confirming to IS:617 standards (for 33KV VCB,33KV L.A,33KV Isolator) with fresh one complete. 68 Supply of Tripping/closing coils suitable for 11KV VCB Panels like Allind,Vijay,Crompton greeves,Easun Reyroll,Alasthom, Electricfield,Sudhir,ABB,L&T etc 69 Providing of clamps (Bi-Metallic) confirming to IS: 1285 standards ( for 33KV P.T Clamps,C.T clamps,Transformer Clamps(Both H.V & L.V Side),Pad Clamps) 70 Providing of 33KV Post Insulatorsby way of replacement of damaged one confirming to IEC 61109/92-93 with latest amendments (porceline type) 71 Supply of 33KV Polymeric Composite Pin Insulator 36KV,10KN,Lighting Impulse 170KV Positive & 180 KV Negative,Creepage distance 900mm sauitable for 0.15/0.2ACSR 72 Providing of 33K VCB Bushes complete assembly by way of replacement of damaged one confirming to IS:2099 standard (porceline type) 73 Providing of 33KV HV Bushes of power transformers complete assembly by way of replacement of damagedoneconfirming to IS:2099 standards (porceline type) 74 Providingof 11KV LV Bushes of transformers complete assembly by way of replacement of damaged one confirming to IS: 2099 standards (porceline type) 75 Supply of 33KV C.T(3-core)confirming to IEC:185 and IS:2705 (part-1 to 4) standardsof ratio 300-150/5-5-5A/ 250-125/5-5-5A)outdoor type 76 Fixing,installation,testing and commissioning of fresh 33KV CT (3-core) of different ratio confirming to IEC:185 and IS:2705 (part-1 to 4) standards by way of replacement of damaged one (material to be provided by the department) outdoor type 77 Supply of33KV P.Tof (110V/√3) confirming to IS:3156 (part-I to Part-III) outdoor type 78 Fixing,installation,testing and commissioning of fresh 33KV PT (110V/√3)confirming to IEC:185 and IS:2705 (part-1 to 4) standards by way of replacement of damaged one (material to be supplied by the department) outdoor type 79 Providing of 33KV isolator 800 Amps heavy duty confirming to IS:9921 / IEC-62271-102 standards 80 With earthing blade 81 Without earthing blade 82 Fixing,installation,testing and commissioning of fresh 33KV isolators 1250 Amps heavy duty confirming to IS:9921 / IEC-62271-102 standards (material to be supplied by the department) (with earthing blade / without earthing blade) 83 Providing of 33KV link set (610x50x6mm male copper balde and female part 200X50x3mm ) by way of replacement of damagedoneheavy duty 600amps. 84 Installation,Testing and commissioning of 33KV link set (610x50x6mm male copper balde and female part 200X50x3mm ) by way of replacement of damagedoneheavy duty 600amps. (material to be supplied by the department) 85 Providing of 11KV G.OSet 200 Amps (with earthing blade) heavy duty conforming to latest version of IS - 9921 (part-I to V) with earthing blade by way of replacement of damaged one 86 Installation,Testing and commissioning of 11KV G.OSet 200 Amps heavy duty conforming to latest version of IS - 9921 (part-I to V)(material to be supplied by the department) 87 Providing, fixing, installation, testing and commissioning of 11KV Isolators,800/630amps. conforming to IS 9921/IEC-129 standards 88 With earthing blade 89 Without earthing blade 90 Installation,Testing and commissioning of 11KV Isolators,800amps. conforming to IS 9921/IEC-129 standards (with earthing blade/without earthing blade )(material to be supplied by the department) 91 Providing, of 11KV link set (400x50x6mm male copper balde and female part 100X50x3mm ) by way of replacement of damagedoneheavy duty 600amps. 92 Installation,Testing and commissioning of 11KV link set (400x50x6mm male copper balde and female part 100X50x3mm ) by way of replacement of damagedoneheavy duty 600amps. (material to be supplied by the department) 93 Providing of 33KV Drop out setwith porcelaine insulatorby way of replacement of damaged one as per latest IS standard with latest amendments therof. 94 Installation,Testing and commissioning of 33KV D.O. set by way of replacement of damaged one as per latest IS standard with latest amendments therof.(material to be supplied by the department) 95 Providing of 33KV L.A. set (porcelaine type with clamps) by way of replacement of damaged one as per latest IS standard with latest amendments therof. 96 Installation,Testing and commissioning of 33KV L.A. set by way of replacement of damaged one as per latest IS standard with latest amendments therof. (material to be supplied by the department) 97 Oil Toping in 33/11 KV Power Transfromersand 33KV MOCBs /CT/PT (Transformer oil to be supplied by the department) 98 Providing of Winding Temperature meter by way of replacement of damaged one suitable for 33/11 KV, 10MVA/6.3MVA/5.0MVA Power Transformers 99 Providing of Oil Temperature meter by way of replacement of damaged one suitable for 33/11 KV , 10MVA/6.3MVA/5.0MVA Power Transformers 100 Providing ofinterrupting chambers (Housing Assembly)suitable for 11KVVCBof different make by way of replacement of damaged one 101 Crompton Greeves 102 S&S 103 Vijai 104 BHEL 105 Alasthom 106 Easun Rey roll 107 Electric Field 108 Installation ofinterrupting chambers (Housing Assembly)suitable for 11KVVCBof different make by way of replacement of damaged one 109 Providing of Arcing interrupting chamberssuitable for33 KVVCB panels of different make by way of replacement of damaged one 110 fixing of Arcing interrupting chamberssuitable for33 KVVCB panels of different make by way of replacement of damaged one 111 Supply of breather of stnadard quality for Power Transformers of different make 112 Providing ofspouts bushing suitable for 11KVVCB (Alasthom/Easun Reyroll/Vijay/Sudhir/Electric field/Crompton greeves/ ABB-Make equiv...) panel of different make by way of replacement of damaged one 113 Providing of Bush Rods suitable for 33/11KVPower Transformer (10MVA/6.3MA/5.0MVA) by way of replacement of damaged one 114 33KV side 115 11KV side 116 36V , 200AH Battery Bank (Comprising of 3 No batteries of 12 V each)conforming to IEC60896-21/22,Lead acid Type of Exide Make 117 Supply of automatic 36V,DC,15amp. (constant current constant voltage ) fully automatic battery charger float cum boost type 2KVA 118 Supply of 11KV (E) grade armoured ,3-core,Xlpe Power Cable (with stranded compact circular aluminium with extruded semi conducting compound,Xlpe insulated and overall PVC sheathed cable confirming to IS:7089 (Part-II)-1985 with the latest amendments by way of replacing the damaged cable of 11KV switchgear (havells or Glastor or finolex make) 119 630mm^²,3-core 120 400mm^²,3-core 121 300mm^²,3-core 122 240mm^²,3-core 123 185mm^²,3-core 124 150mm^²,3-core 125 Laying,Testing,commissioning of 11KV (E) grade armoured ,3-core,Xlpe Power Cable (with stranded compact circular aluminium with extruded semi conducting compound,Xlpe insulated and overall PVC sheathed cable confirming to IS:7089 (Part-II)-1985 with the latest amendments by way of replacing the damaged cable of 11KV switchgear(material to be supplied by the department) 126 630mm^²,3-core 127 400mm^²,3-core 128 300mm^²,3-core 129 240mm^²,3-core 130 185mm^²,3-core 131 150mm^²,3-core 132 120mm^²,3-core 133 Supply of 11KV (E) grade armoured ,1-core,Xlpe Power Cable (with stranded compact circular aluminium with extruded semi conducting compound,Xlpe insulated and overall PVC sheathed cable confirming to IS:7089 (Part-II)-1985 with the latest amendments by way of replacing the damaged cable of 11KV switchgear (havells or Glastor or finolex make) 134 630mm^²,1-core 135 400mm^²,1-core 136 300mm^²,1-core 137 240sqmm, 1-core 138 185mm^²,1-core 139 150mm^²,1-core 140 120mm^²,1-core 141 Laying,Testing,commissioning of 11KV (E) grade armoured ,1-core,Xlpe Power Cable (with stranded compact circular aluminium with extruded semi conducting compound,Xlpe insulated and overall PVC sheathed cable confirming to IS:7089 (Part-II)-1985 with the latest amendments by way of replacing the damaged cable of 11KV switchgear(material to be supplied by the department) 142 630mm^²,1-core 143 400mm^²,1-core 144 300mm^²,1-core 145 240mm^²,1-core 146 185mm^²,1-core 147 150mm^²,1-core 148 120mm^²,1-core 149 Supply of 2.5 sqmm Control cable armored , copper conductor sheathedPVC insulated multi colour voltage grade 1.1 KV conforming to IS:1554(Part 1),IS 8130,IS ;5831 (Havells or Gloster or finolex make ) 150 2 core 151 4 core 152 6 core 153 8 core 154 12 core 155 Supply of 11KV ,3 core heat shrinkablestraight through jointing cable kit(outdoor Type) suitable for already installed 11KV Xlpe Power Cable confirming to IS:13573/1993with latest ammendments if any (3M or RAYCHEM make) 156 630mm^²,3-core 157 400mm^²,3-core 158 300mm^²,3-core 159 240mm^²,3-core 160 185mm^²,3-core 161 150mm^²,3-core 162 120mm^²,3-core 163 Supply of 11KV cable 3 core terminationkits (Indoor/ outdoor Type)3M or Raychem 164 630mm^²,3-core 165 400mm^²,3-core 166 300mm^²,3-core 167 240mm^²,3-core 168 185mm^²,3-core 169 150mm^²,3-core 170 120mm^²,3-core 171 Installation,Testing and commissioning of 11KV cable Jointing/ terminationkits (indoor Type)(material to be provided by the department) 172 630mm^²,3-core 173 400mm^²,3-core 174 300mm^²,3-core 175 240mm^²,3-core 176 185mm^²,3-core 177 150mm^²,3-core 178 120mm^²,3-core 179 Supply of 11KV ,1 core heat shrinkablestraight through jointing cable kit(outdoor Type) suitable for already installed 11KV Xlpe Power Cable confirming to IS:13573/1993with latest ammendments if any (3M or RAYCHEM make) 180 630mm^²,1-core 181 400mm^²,1-core 182 300mm^²,1-core 183 240mm^²,1-core 184 185mm^²,1-core 185 150mm^²,1-core 186 120mm^²,1-core 187 Supply, of 11KV cable 1 core terminationkits (Indoor/ outdoor Type)3M or Raychem 188 630mm^²,1-core 189 400mm^²,1-core 190 300mm^²,1-core 191 240mm^²,1-core 192 185mm^²,1-core 193 150mm^²,1-core 194 120mm^²,1-core 195 Installation,Testing and commissioning of 11KV cable jointing/ terminationkits (indoor Type)(material to be provided by the department) 196 630mm^²,1-core 197 400mm^²,1-core 198 300mm^²,1-core 199 240mm^²,1-core 200 185mm^²,1-core 201 150mm^²,1-core 202 120mm^²,1-core 203 Dragging(upto Avg. lead 50 mtrs.)and rotation (if required) of 33/11KV Power Transformer (Complete Job) 204 10 MVA 205 6.3 MVA 206 5.0/4.0/3.15 MVA 207 Loading of Power Transformer to the sub station bed / plateform (Complete Job) 208 10 MVA 209 6.3 MVA 210 5.0/4.0/3.15 MVA 211 Unloading of Power Transformer fromthe sub station bed / plateform (Complete Job) 212 10 MVA 213 6.3 MVA 214 5.0/4.0/3.15 MVA 215 Carriage of Power Transformer upto 20KM fromsource to destinantion 216 10 MVA 217 6.3 MVA 218 5.0/4.0/3.15 MVA 219 Carriageof Power Transformer (10/6.3/5/4/3.15 MVA) beyond 20KM 220 Unloading of material which are to be handled with care like 33KV CT / 33KV PT etcincluding manual carriage from dumping site upto proper stacking 221 Loading of of material which are to be handled with care like 33KV CT / 33KV PTetc including manual carriagestacking site upto loading 222 Manual Carriage of materials like 33KV CT / 33KV PT 33KV C&R panel , 33KV VCB panel , 11KV VCB panel etc 223 Upto first 100mtr lead 224 For every additional 50mtr or part there off 225 Unloading of bulky material which are to be handled with care like 33KV C&R panel , 33KV VCB panel , 11KV VCB panel etc including manual carriage from dumping site upto proper stacking 226 Supply ofGears for 11KV VCB of different make(Big) 227 Supply ofGears for 11KV VCB of different make(Small) 228 Supply ofDC Delco Motor for 33 KV VCB 229 Supply ofDC Delco Motor for 11 KV VCB 230 Supply of Breaker Mechanism of reputed make 231 Loading of bulky material which are to be handled with care like 33KV C&R panel , 33KV VCB panel , 11KV VCB panel etc including manual carriagestacking site upto loading 232 Supply ,installation,testing and commissioning of copper Bus Bar (50x8mm) tin coated with duly heat shrinked insulated 233 Repairing /Replacement of 11KV VCBs 234 Tripping Mechanism 235 Modification of Mechanism 236 Re-setting links 237 Replacement of operating shaft 238 Shower contact 239 Isolating Sockets 240 Closing mechanism (replacement) 241 High Tension spring 242 Tripping shaft 243 Rollers 244 Latch assembly 245 Overhauling of 11KV VCB 246 Deco spray painitng 247 Installation,Testing and commissioning of Power Transformer of capcity (3.15/4 MVA/5MVA/6.3 MVA/10MVA) complete job including all neceesary testing at site 248 Dismanteling of Power Transformer of capcity (3.15MVA /4 MVA /5MVA /6.3MVA /10MVA) complete job 249 Supply of 33KV, Single coreAluminium, round wire Armoured XLPE Cable , FRLS One spare cable 250 185sqmm 251 240sqmm 252 300sqmm 253 400sqmm 254 630sqmm 255 Laying,testing and commissioningof 33KV, Single coreAluminium, round wire armoured XLPE Cable , FRLS One spare cable 256 185sqmm 257 240sqmm 258 300sqmm 259 400sqmm 260 630sqmm 261 Providing of Cable Termination Kits (indoor/outdoor) for 33KV Grade single core cable of size 262 185sqmm 263 240sqmm 264 300sqmm 265 400sqmm 266 630sqmm 267 Laying,testing & commissioning of Cable Termination Kits (indoor/outdoor) for 33KV Grade single core cable of size 268 185sqmm 269 240sqmm 270 300sqmm 271 400sqmm 272 630sqmm 273 Supply of Buchhloz relay for 33/ 11 KV transformer protection(10MVA / 6.3 MVA) as per IS 3637:1966 274 Supply of G.I Bolt full threadof sorts of dia 3/4’’ and 1/2 “ with washers and nuts of different sorts and sizes 275 Supply of G I Wire (8 SWG) as per IS standard with latest amendments 276 Supply of Guy wire(7/14) SWG as per IS standard with latest amendments 277 Supply of Digital Protection Relay non-communicableModel Type -141A(Ashida -Make), 3 O/C + 1 E/F , auxilairy voltage 0-30Vconfirming to ISO 9001:2008 standards. 278 Supply of progammable numerical relay with communication protocol IEC618503 O/C + 1 E/F with SCADA compatible relay VAMP57 (IEM) protection,relay type V57F3ABA1ACA, (Schneider make)having ports dual RJ45 with 10 digital inputs and 6 digital outputs, auxiliary voltage =30V minimum, frequency = 50hz, rated phase current In=5A, rated residual current Io=5A, Rated auxiliary voltage (Uaux)=30 DC 279 Supply of Push type ON-OFF switches suitable for 33/11kV Pannel boardmake BHEL,Crompton Greeves, Alsthom, ABB, New Electric Field, Sudhir or the like 280 Supply of Trip solenoids voltage operated coil (D.C 30-36V) complete encased suitable for11KV VCB Panels Allind / Vijay / Easun reyroll / Alasthom / Crompron Greeves / New Electric Field / Schneider / BHEL/Pascal/ABB make 281 Supply of 11kV Lightnening Arrestor station Type (Poreclaineinsulators) 282 Supply of HT Tape Roll as per IS standard with latest amendments 283 Supply of indication lamps suitable for 33/11kV Pannel board make BHEL,Crompton Greeves, Alsthom, ABB, New Electric Field, Sudhir etc 284 Supply of Monoplast Tape as per IS standard with latest amendments 285 Supply of LT insulation tape as per IS standard with latest amendments 286 Supply of master trip relay 24-50 V suitable for 11KV VCB Switch gear panels of Allind / Vijay / Easun reyroll / Alasthom / Crompron Greeves / New Electric Field / Schneider / BHEL/Pascal/ABB and like make 287 Supply of Auxiliary switch suitable for 11KV VCB panels like Beeco lawrie, Easun reyroll,Allind,Vijay,Alsthom,Crompron greeves Electricfield /Pascal/ABB 288 Supply of selector switch suitable for 11KV VCB Panels like Beeco lawrie, Easun reyroll,Allind,Vijay,Alsthom,Crompron greeves Electricfield /Pascal/ABB 289 Supply of aluminium thimbles of different sizes (185sqmm/240sqmm/300sqmm/400sqmm) of 3D or Dowells make 290 Supply of ampere meter (digital type) suitable for 11KV VCB panels 291 Supply ofVoltmeter(digital type) suitable for 11KV VCB panels 292 Supply of old sarees 293 Supply of welding electrodes as per IS standard with latest amendments 294 Supply of Petrolium jelly as per IS standard 295 Earthing Complete by G I Pipe 40mm or G I Rod 20mm 2.5 Mtr long through G I Strip as per REC Standard 296 Galvanised Stay set with 50X8mm Stay Clamps,Guy Insulator,Anchor Plat(300X300X8)mm,Nuts/Bolts ,Turn Buckle,1.8 Mt long 20mm Dia Sold GS Stay rod & 7/4.0mm Dia GI Std wire complete 297 Porceline 70 KN Disc Insulator 298 Porceline 45 KN Disc Insulator 299 Porceline 33KV Insulators (10 KN) 300 33KV G.I Pins with all accessories weighing 2700 gms 301 Fabricated Galvanised V -type Channel Iron X-arm,6-10 Long Ch Iron,Channel Iron Top,Angle Iron Belts, Clamps & Flat braces etc as per REC Standard for 33/11KV Lines. 302 33KV Polymeric Composite Pin Insulator 36KV,10KN,Lighting Impulse 170KV Positive & 180 KV Negative,Creepage distance 900mm sauitable for 0.1ACSR 303 33 KV Polymeric Composite Disc Insulator 36KV,Min failing load 70KN,Lighting Impulse 170KV Positive & 180 KV Negative,Creepage distance 900mm suitable for 0.05/0.1 ACSR Conductor 304 33 KV Polymeric Composite Disc Insulator 36KV,Min failing load 70KN,Lighting Impulse 170KV Positive & 180 KV Negative,Creepage distance 900mm suitable for 0.15/0.2 ACSR Conductor 305 P G Clamps for 200/150/100mm Sq ACSR 306 Supply of LED Yard lights 50 watts of philips/Havells 307 Supply of LT Aluminium cable of 10sqmm single core as per ISIS-7098 (Part-1) -1988 with latest amendments 308 Supply ofLED lamps 9 watt of philips/Havells make 309 Supply of LED Search light handled torch,3W (with built-in,rechargeable 4.5 Ah SMF battery),lighting range of upto 600meters 310 Filling of CO2 type Fire Extinguishers of 6.8Kg capacity 311 Supply of digital earth resistance tester having range from 0-2000 ohm (complete with operating manuals and drawings) 312 Supply of Safety Belt of class A & P harness including waist belt and a pole strap with a special type of freely moving buckle complete conforming toI.S.3521-1999 313 Supply of fire bucket with handle of 10 litre capacity duly painted as per standard 314 Supply of Safety Helmet conforming to ISO: 3873, IS 2925 : 1984 315 Supply of Electrical insulated CheckeredRubber Matting 25mm thick (1mtrX2mtr) conforming to IS 15652:2006, EC 61111 316 Supply of Meggar 5KVA battery operated (complete with operating manuals and drawings) 317 Supply of Pully Machine (complete with manuals) 318 5 Ton 319 10 Ton 320 Supply of Chain Pully Block (complete with manuals) 321 5 Ton 322 10 Ton 323 Supply of CO2 type Fire Extinguishers of 6.8Kg capacity fitted with trolley, delivery hose horn, wheel type release value etc (complete) 324 Supply of ABC Type Fire Extinguishers of 6.8Kg capacity fitted with pipes nozzles and all accessories 325 Supply of motor for spring charge suitable for 33/11kV switchgear make BHEL,Crompton Greeves, Alsthom, ABB, New Electric Field, Sudhir or the like 326 Supply of manually operated crimping tool of 3D or dowels make 327 Supply of aluminium ladder 40ft long, folded type (5-6mm thick) with rope and pully complete 328 Supply of 50sqmm welding cable of standard make(ISI marked) 329 Supply of heavy duty welding holder (500-1000A) as per IS standard with latest amendments 330 Supply of welding gloves as per IS standard with latest amendments (ISI marked) 331 Supply of heavy duty355-3.0X25(4mm) Cutting Blade (14’’)as per IS standard with latest amendments (Bosch make) 332 Supply of fibre type measuring tape (30m) of Topline or equivalent make(ISI marked) 333 Supply of heavy duty gas cutter as per IS standard with latest amendments of Kakkar or equivalent make. (ISI marked) 334 Supply of heavy duty gas gauge as per IS standard with latest amendments of Kakkar or equivalent make. (ISI marked) 335 Supply of 150mm,6’’ angle grinder of Hitachi or equivalent make(ISI marked) 336 Supply of 150mm,6’’ heavy duty cutting wheel blade of Bosch or equivalent make (ISI marked) 337 Supply of 3-phase Tri vector energy meter suitable for 11kV Panels / 33KV C&R panels make BHEL,Crompton Greeves, Alsthom, ABB, New Electric Field, Sudhir etc 338 Supply of Panel Bush for 11KV VCB panels like Easun Reyroll, Allind, Alsthom, Crompton Greeves, New Electric Field,ABB 339 Supply of Breaker Bush for 11KV VCB panels like Easun Reyroll, Allind, Alsthom, Crompton Greeves, New Electric Field,ABB 340 Supply of TNC/Local-Remote switch suitable for 11KV VCB panels like Easun Reyroll, Allind, Alsthom, Crompton Greeves,ABB, New Electric Field 341 Supply ofHeat Shrinkable cable Termination kits of 3M or Raychem make (outdoor Type) suitable for 33KV 3- core,Xlpe power cables 342 630sqmm 343 400sqmm 344 300sqmm 345 Laying,installation,testing ofHeat Shrinkable cable Termination kits of 3M or Raychem make (outdoor Type) suitable for 33KV 3- core,Xlpe power cables 346 Supply of standard quality Silica jel for various Capacity 33/11kV power transformers 347 Supply of tool kit as per IS standard with latest amendments 348 Providing and fixing of yard lights of 50watt along with 2.5sqmm 1 core PVC cable of 50mtrs and one MCB 6/16Amp. 349 Supply of Portable HEAVY DUTY ARC welding machines alongwith all accessories of standard Make 350 Supply of BDV Testing machines of standard Make 351 Supply of BDV woodcutter of standard Make 352 Supply of Conductor cutter of standard Make suitable for 0.2 ACSR Conductor 353 Supply of haevu duty Hydraulic crimping tool (40-400mm) of standard make 354 Providing of 3 Phase Turn ratio Meter of Reputed make 355 Providing of widing Resistance Meter of Reputed make 356 Proding of Gyser Element of reputed make as per requirement 357 Providing ond fixing of heavy duty fans along with Stand for forced cooling of Power Transformers 358 Proving of Limit Switch for VCBs of different Make 359 Proving of Antipumping Relays for VCBs of different Make 360 Proving of Announciator for VCB/ C & R Panel of different Make 361 4 Window 362 8 Window 363 Proving of Buzzer/Hooter (24-48V) for VCB/ C & R Panel of different Make 364 Proving of HRC fused 6A/10A for VCB/ C & R Panel of different Make 365 Proving of AVT fused 1A for 11KV/110V PT for replacement of damaged one 366 Supply and Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer’s specifications including appropriate priming coat, preparation of surface etc complete, on steel work including Channel iron, Angle iron, chainlink fencing and ST poles.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 9
Jammu And Kashmir View Result →
12.
Youth Affairs and Sports and Culture #10721205 Price Bid
Rate For First-Aid & Consumables Items 2025 , Item Wise Boq 15.0 Boq_Ver3.0 Item Wise Normal Inr Only Inr Select, Excess (+), Less (-) Tender Inviting Authority: Director Sports And Youth Welfare, T.T. Nagar Stadium Bhiopal Name Of Work: Rate For First-Aid & Consumables Items 2025 Contract No: Name Of The Bidder/ Bidding Firm / Company : Price Schedule (Domestic Tenders - Rates Are To Given In Rupees (Inr) Only) (This Boq Template Must Not Be Modified/Replaced By The Bidder And The Same Should Be Uploaded After Filling The Relevant Columns, Else The Bidder Is Liable To Be Rejected For This Tender. Bidders Are Allowed To Enter The Bidder Name And Values Only ) Number # Text # Text # Number # Text # Number Number Text Text # Number # Text# Text # Number # Number Number Number Number Text Text Number Number Number Number Text Text Number Number Number Number Text Text Number Number Number Number Text Text Number Number Number Number Text Text Number Number Number # Number # Text Text Number # Number # Date Number # Number # Text # Sl. No. Product Name & Specification Item Code / Make Quantity Units Estimated Rate In Rs. P Addition / Deduction Addition / Deduction Values Currency Convertion Against Each Item Quoted Currency In Inr / Other Currency Basic Rate In Figures To Be Entered By The Bidder In Rs. P Excise Duty Amount In Inr Rs. P Gst Amount In Inr Rs. P Freight Charges ( Unloading & Stacking) In Rs. P Any Other Taxes In Rs. P Any Other Duties/Levies In Rs. P Less For Cenvat Credit,If Any Respect Of Supplies Under Full Excise Duty Category Name Of Manufacturer/ Brand Total Amount Without Taxes In Rs. P Total Amount With Taxes Col (14) = Sum (8) To (13) In Rs. P Total Amount In Words , Firstaid & Consumables , Arm Sling , Shoulder Immobilization Sling , Shoulder Support With Movement Limitation , Clavicle Support , Adjustable Abduction Shoulder Support , 15-Degree Abduction Shoulder Support , 45-Degree Abduction Shoulder Support , Elastic Elbow Support , Elbow Support With Silicone Pads , Elastic Elbow Support With Pads , Epicondylitis Elbow Strap , Elbow Mobilization Orthosis , Wrist And Forearm Immobilization Support , Wrist Support , Carpal Tunnel Wrist Support , Thumb Support , Soft Cervical Support , Cervical Immobilization Collar , Posture Correction T-Shirt , Back Orthosis For Vertebral Extension , Taylor Brace For Hyperkyphosis , 4-Point Spinal Hyperextension Brace , Flexible 4-Point Spinal Hyperextension Brace , Abdominal Support Bandage , Basic Lumbar Stabilizing Support , Economical Lumbar Support , Lumbar Support With Massage Pad , Lumbar Stabilizing Support , Lumbar Orthosis With Tension Straps , Adjustable Lumbar Stabilizing Support , Sacroiliac Stabilizing Brace , Maternity Support Belt , Hip Joint Orthosis (Hip) , Hip Joint Orthosis (Thigh) , Elastic Knee Support - Basic , Elastic Knee Support - Top Silicone Band , Elastic Knee Support - Steel Spiral , Elastic Knee Support - Open Patella , Patella Support Knee Brace , Elastic Knee Support With Patellar Ring , Patellar Tendon Support , Patellar Lateralization Knee Support , Patellar Tendon Pain Relief Knee Brace , Physiological Knee Orthosis , Short Functional Knee Brace , Long Rigid Knee Brace (4-Point) , Short Knee Brace With Rom Limit , Short Functional Knee Brace , Rigid Acl Brace With Hinges , Rigid Acl Brace With Hinges - Comfort , Dynamic Pcl Knee Brace , 4-Point Acl/Pcl Knee Brace , Hyperextension Knee Brace , Lightweight Oa Knee Brace , Oa Knee Brace With Wrap , Soft Oa Knee Brace With Rom , 4-Point Oa Knee Brace , Pcl Immobilisation Brace , Universal Knee Immobilizer , Compression Ankle Support , Silicone Ankle Support , Elastic Ankle Support With Strap , Achilles Tendon Support With Silicone Pad , Elastic Achilles Tendon Support , Foam-Gel Ankle Brace , Lace-Up Ankle Brace , Adjustable Ankle-Foot Drop Brace , Standard Walker Boot , Rom Adjustable Walker Boot , Fixed Walker Boot , Pneumatic Air Walker Boot , Silicone Foot Support - Heel Soft , Silicone Foot Support - Insole , Toe Spreader , Forefoot Cushion , Performance Elbow Support , Performance Lumbar Support , Performance Knee Support For Soft Tissue Compression , Sporty Ankle Support , Shoulder Immobilization Brace - Kidz , Knee Immobilization Brace - Kidz , Wrist Immobilization Brace - Kidz , Ankle Foot Immobilization Brace - Kidz , Ankle Orthosis For Stabilisation - Kidz , Orthopedic Insole - Sport , Orthopedic Insole - Comfort , Orthopedic Insole - Comfort Pro , Orthopedic Insole - Carbon , Anti-Embolism Calf Stocking , Anti-Embolism Thigh Stocking , Anti-Embolism Thigh Stocking With Waist Attachment , Surgical Compression Calf Stocking White , Surgical Compression Thigh Stocking White , Surgical Compression Calf Stocking Brown , Surgical Compression Thigh Stocking Brown , High Compression Calf Stocking White , High Compression Thigh Stocking White , High Compression Calf Stocking Brown , High Compression Thigh Stocking Brown , Adjustable Lower Leg Compression Wrap , Adjustable Ankle Foot Compression Wrap , Premium Adjustable Lower Leg Compression Wrap , Premium Adjustable Upper Leg Compression Wrap , Adjustable Arm Compression Sleeve , Adjustable Hand Compression Wrap , Waist To Mid-Thigh Compression Garment , Breast To Ankle Compression Garment , Breast To Knee Compression Garment , Breast To Mid-Thigh Compression Garment , Waist To Thigh Compression Garment , Breast To Thigh Compression Garment , Compression Belt , Compression Bra , Digital Wrist Blood Pressure Monitor , Digital Upper Arm Blood Pressure Monitor , Digital Upper Arm Blood Pressure Monitor (Bluetooth) , Digital Upper Arm Blood Pressure Monitor On Arm (No Hose/Cable) , Digital Upper Arm Blood Pressure Monitor With Ecg Function , Glucometer With Strips , Body Composition Monitor , Bmi Scale , Ankle Tens , Knee And Elbow Tens , Digital Tens/Ems Unit , Digital Tens/Ems Device With Heat , Menstrual Relax , Foot Massager , Footbath Massager , Facial Sauna , Clinical Thermometer , Ear Thermometer , Non-Contact Thermometer , Hearing Amplifier , Heated Under Blanket , Electric Blanket , Back & Neck Heating Pad , Steam Vapouriser , Nebulizer , Ir Lamp - 100W , Ir Lamp - 150W , Ir Lamp - 300W , Ir Lamp Replacement Bulb - 100 W , Ir Lamp Replacement Bulb - 150 W , Air Purifier - 26Msq , Air Purifier - 54Msq , Air Purifier - 106Msq , Yoga Strech Mat - With Vibration & Heat , Infrared Massager , Physio Gun , Pulse Oximeter , Analogue Weighing Scale , Digital Weighing Scale , Hypervolt Go 2 , Hypervolt 2 Pro , Hypervolt 2 , Normatec 3 Leg Package - Standard , Normatec Premier , Normatec Go , Normatec 3 Hip Attachment , Normatec Arm Attachment , Vyper 3 Eu , Hypersphere Mini Black , Hypersphere Black , Venom 2 Back , Venom 2 Leg , Venom Go , Venom 2 Right Shoulder , Venom 2 Left Shoulder , Venom Pod Shoulder Right , Venom Pod Shoulder Left , Heated Hypervolt Head Attachment , Hypervolt Charger Head Eu/Usa/India , Hypervolt Head Attachments , Hypervolt Case , Hypervolt Go 2 Charging Dock , Hypervolt 2 Charging Dock , Hypervolt 2 Pro Charging Dock , Hypervolt Eva Case Black One Size , Venom Go Case , Venom Go Refill Pack , Normatec Carry Case , Hyperice Carry Case (Normatec) , Pulse Carry Case Black One Size (Normatec) , Normatec 3 Backpack , Theragun Elite , Theragun Prime Plus , Theragun Pro Plus , Theragun Relief , Theragun Sense , Theragun Mini , Theragun Mini 2.0 , Theraface Pro , Therabody Recoverytherm Cube , Therabody Hot And Cold Knee , Achedaway Mini Scraper , Achedaway Heated Muscle Scra , Achedaway Cupper , Achedaway Cupper Duo , Compex Sp 5.0 , Compex Sp 8.0 , Game Ready Grpro 2.1 , Mueller Revive™ M4 , Mueller Revive™ M2 , Portable Heat, Cold, Contrast & Compression Therapy Machine (Mueller Therm X) , Mueller Therm X Garments Each , Clx Loop Red , Clx Loop Green , Clx Loop Blue , Clx Loop Black , Clx Loop Silver , Clx Loop Gold , Resistance Loop 12” - Red , Resistance Loop 12” - Green , Resistance Loop 12” - Blue , Resistance Band – Very Light – 1.5 Mtr (Yellow) , Resistance Band – Light – 1.5 Mtr (Red) , Resistance Band – Medium – 1.5 Mtr (Green) , Resistance Band – Heavy – 1.5 Mtr (Blue) , Resistance Band – Extra Heavy – 1.5 Mtr (Black) , Resistance Band – Super Heavy – 1.5 Mtr (Silver) , Resistance Band – Maximum Resistance – 1.5 Mtr (Gold) , Active Recovery Kit Eu/La Beginner , Active Recovery Kit Eu/La Adv , Resistance Band – Very Light – 5.7 Mtr (Yellow) , Resistance Band – Light – 5.7 Mtr (Red) , Resistance Band – Medium – 5.7 Mtr (Green) , Resistance Band – Heavy – 5.7 Mtr (Blue) , Resistance Band – Extra Heavy – 5.7 Mtr (Black) , Resistance Band – Super Heavy – 5.7 Mtr (Silver) , Resistance Band – Maximum Resistance – 5.7 Mtr (Gold) , Yellow Tubing Thera-Band 25Ft , Red/Medium Thera-Band Tubing 25Ft Disp Box , Green/Hvy Thera-Band Tubing 25Ft Disp Box , Blue/Ext Hvy Thera-Band Tubing 25Ft Disp Box , Black/Special Hvy Thera-Band Tubing 25Ft Disp Box , Silver/Super Hvy Thera-Band Tubing 25Ft Disp Box , Yellow Tubing 100 Ft , Red Tubing 100 Ft , Green Tubing 100 Ft , Blue Tubing 100 Ft , Black Tubing 100 Ft , Silver Tubing 100 Ft , Yellow Tubing W/Soft Handle , Red Tubing With Soft Handle , Green Tubing With Soft Handle , Blue Tubing With Soft Handle , Black Tubing With Soft Handle , Silver Tubing With Soft Handle , Resistance Tubes Light Retail , Resistance Tubes Heavy Retail , Red Tubing Loop W/Padded Cuff , Green Tubing Loop W/Padded Cuff , Blue Tubing Loop W/Padded Cuff , Black Tubing Loop W/Padded Cuff , Rehab And Wellness Station , Door Anchor , Accessories Kit , Assist Strap , Sports Handle , Exercise Handle , 18/45Cm Yellow Exercise Ball , 22/55Cm Red Exercise Ball , 26/65Cm Green Exercise Ball , 30/75Cm Blue Exercise Ball , 33/85Cm Silver Exercise Ball , Pro Series Gym Ball Yellow , Pro Series Gym Ball Red , Pro Series Gym Ball Green , Pro Series Gym Ball Blue , Mini Ball Yellow , Silver Stability Disc 13” , Blue Stability Trainer , Green Stability Trainer , Black Stability Trainer Inflate , Rocker Board , Wobble Board , Flexbar-Yellow , Flexbar-Red , Flexbar-Green , Flexbar-Blue , Finger Flexion Exercise Disc Red , Finger Flexion Exercise Disc Green , Finger Flexion Exercise Disc Blue , Finger Flexion Exercise Disc Black , Finger Flexion Xtrainer Assorted Disc Pack , Yellow Hand Exerciser Ball , Red Hand Exerciser Ball , Green Hand Exerciser Ball , Blue Hand Exerciser Ball , Black Hand Exerciser Ball , Tan Soft Weight Ball (0.5Kg) , Yellow Soft Weight Ball (1Kg) , Red Soft Weight Ball (1.5Kg) , Green Soft Weight Ball (2Kg) , Blue Soft Weight Ball (2.5Kg) , Black Soft Weight Ball (3Kg) , Red Ankle Weight - 1 Kg Pair (0.5Kg Each) , Green Ankle Weight - 1.4 Kg Pair (0.7Kg Each) , Blue Ankle Weights - 2.2 Kg Pair (1.1Kg Each) , Shoulder Pulley , Stretch Strap , High Resistance Band Light And Medium (Color: Orange And Green) , High Resistance Band Medium And Heavy (Color: Green And Blue) , High Resistance Band Heavy And X Heavy (Color: Blue And Purple) , Digi-Flex Hand Exercisers - Tan, Xx-Light - Finger (0.75 Lbs) / Hand (2.5 Lbs) , Digi-Flex Hand Exercisers - Yellow, X-Light - Finger (1.5 Lbs) / Hand (5.0 Lbs) , Digi-Flex Hand Exercisers - Red, Light - Finger (3.0 Lbs) / Hand (10.0 Lbs) , Digi-Flex Hand Exercisers - Green, Medium - Finger (5.0 Lbs) / Hand (16.0 Lbs) , Digi-Flex Hand Exercisers - Blue, Heavy - Finger (7.0 Lbs) / Hand (23.0 Lbs) , Digi-Flex Hand Exercisers - Black, X-Heavy - Finger (9.0 Lbs) / Hand (31.0 Lbs) , Digi-Flex Hand Exercisers - Silver, Xx-Heavy - Finger (11.0 Lbs) / Hand (38.0 Lbs) , Digi-Flex Hand Exercisers - Gold, Xxx-Heavy - Finger (13.0 Lbs) / Hand (45.0 Lbs) , Digi-Flex Hand Exercisers - Set Of 5 (Yellow, Red, Green, Blue, Black), No Rack , Digi-Flex Hand Exercisers - Set Of 5 (Yellow, Red, Green, Blue, Black), With Metal Rack , Digi-Flex Hand Exercisers - Set Of 8 (Tan, Yellow, Red, Green, Blue, Black, Silver, Gold), No Rack , Digi-Flex Hand Exercisers - Set Of 8 (Tan, Yellow, Red, Green, Blue, Black, Silver, Gold), With Metal Rack , Mvp Balance System, 10-Ball Set (2 Each Yellow - Black), No Rack , Plastic Adjustable Multi Slant And Calf Stretcher Board , Finger Weights, Multicolor, Set Of 10 , Wobble Ball, 18 , Pronation/Supination Wrist Exercise Wheel , Gel-Hand Exercise Balls - 6-Piece Set (Tan Through Black) , 360 Stick Vibration Exerciser , Inflatable Exercise Sensi-Ball - Orange - 22 (55 Cm) , Inflatable Exercise Sensi-Ball - Green - 26 (65 Cm) , Inflatable Exercise Sensi-Ball - Red - 30 (75 Cm) , Inflatable Exercise Sensi-Ball - Blue - 34 (85 Cm) , Inflatable Exercise Sensi-Ball - Red - 39 (95 Cm) , Inflatable Exercise Saddle Roll (Peanut Gym Ball) - Yellow - 16 Dia X 35 L (40 Cm Dia X 90 Cm L) , Inflatable Exercise Saddle Roll (Peanut Gym Ball) - Orange - 20 Dia X 39 L (50 Cm Dia X 100 Cm L) , Inflatable Exercise Saddle Roll (Peanut Gym Ball) - Green - 24 Dia X 43 L (60 Cm Dia X 110 Cm L) , Inflatable Exercise Saddle Roll (Peanut Gym Ball) - Red - 28 Dia X 47 L (70 Cm Dia X 120 Cm L) , Inflatable Exercise Saddle Roll (Peanut Gym Ball) - Blue - 32 Dia X 51 L (80 Cm Dia X 130 Cm L) , Inflatable Exercise Sensi-Saddle Rolls - Yellow - 16 Dia X 35 L (40 Cm Dia Cm X 90 Cm L) , Inflatable Exercise Sensi-Saddle Rolls - Orange - 20 Dia X 39 L (50 Cm Dia X 100 Cm L) , Inflatable Exercise Sensi-Saddle Rolls - Green - 24 Dia X 43 L (60 Cm Dia X 110 Cm L) , Inflatable Exercise Straight Rolls - Yellow - 16 Dia X 35 L (40 Cm Dia X 90 Cm L) , Inflatable Exercise Straight Rolls - Orange - 20 Dia X 43 L (50 Cm Dia X 100 Cm L) , Inflatable Exercise Straight Rolls - Green - 24 Dia X 53 L (60 Cm Dia X 110 Cm L) , Donut Ball - Yellow - 18 Dia X 10 H (45 Cm Dia X 25 Cm H) , Donut Ball - Orange - 22 Dia X 12 H (55 Cm Dia X 30 Cm H) , Donut Ball - Green - 26 Dia X 14 H (65 Cm Dia X 35 Cm H) , Donut Ball - Red - 30 Dia X 16 H (75 Cm Dia X 40 Cm H) , Donut Ball - Blue - 34 Dia X 18 (85 Cm Dia X 45 Cm H) , Theraputty Standard Exercise Putty, 6 Piece Set (Tan, Yellow, Red, Green, Blue, Black), 4 Oz , Val-U-Putty Exercise Putty, 6 Piece Set, 1 Lb. , Power-Web - 14 - Level 1 - Tan , Power-Web - 14 - Level 2 - Yellow , Power-Web - 14 - Level 3 - Red , Power-Web - 14 - Level 4 - Green , Power-Web - 14 - Level 5 - Blue , Power-Web - 14 - Level 6 - Black , Power-Web Combo - 14 - Level 1 & 3 - Tan/Red , Power-Web Combo - 14 - Level 2 & 4 - Yellow/Green , Power-Web Combo - 14 - Level 3 & 5 - Red/Blue , Power-Web Combo - 14 - Level 4 & 6 - Green/Black , Power-Web Jr - 7 - Level 2 - Yellow Junior , Power-Web Jr - 7 - Level 3 - Orange Junior , Power-Web Jr - 7 - Level 3 - Red Junior , Power-Web Jr - 7 - Level 4 - Green Junior , Double Massage Ball 8Cm*16Cm , Spiky Massage Ball 6Cm , Spiky Massage Ball 7Cm , Spiky Massage Ball 8Cm , Spiky Massage Ball 9Cm , Spiky Massage Ball 10Cm , Lacrosse Foot Massager Ball - 60Mm , Lacrosse Foot Massager Ball - Peanut Roller Plain 15Cm , Lacrosse Foot Massager Ball - Peanut Roller Spiky 15Cm , Acupressure Hemisphere Massage Ball - 8Cm , 8 Hand Pump , Manual Compression Therapy Wrap Knee , Manual Compression Therapy Wrap Elbow , Manual Compression Therapy Wrap Ankle , Manual Compression Therapy Wrap Wrist , Rigid Ankle Immobilization Walker Long , Rigid Ankle Immobilization Walker Short , Semi-Rigid Ankle Immobilization Walker Long , Semi-Rigid Ankle Immobilization Walker Short , Bunion Correction Splint , Instant Hot Pack, Disposable - 5 X 7 Case Of 24 , Instant Hot Pack, Disposable - 4.5 X 9 Case Of 24 , Instant Hot Pack, Disposable - 6 X 9 Case Of 24 , Instant Cold Pack, Disposable (5.5 X 7) , Reusa/Eu/Australiable Hot/Cold Gel Pack (14Cm X 18 Cm) , Reusa/Eu/Australiable Hot/Cold Gel Pack With Adjustable Brace , Reusa/Eu/Australiable Hot/Cold Foot Ice Pack Hot Cold Therapy , Cotton Crepe Bandage 6 Cm X 4 Mtr , Cotton Crepe Bandage 8 Cm X 4 Mtr , Cotton Crepe Bandage 10 Cm X 4 Mtr , Cotton Crepe Bandage 15 Cm X 4 Mtr , Iv Cannula Fixator 4.5 Cm X 6 Cm , Plaster Of Paris Bandage 7.5 Cm X 2.7 Mtr , Plaster Of Paris Bandage 10 Cm X 2.7 Mtr , Plaster Of Paris Bandage 15 Cm X 2.7 Mtr , Plaster Of Paris Slab 10 Cm X 60 Cm , Plaster Of Paris Slab 15 Cm X 75 Cm , Plaster Of Paris Slab 15 Cm X 100 Cm , Cast Padding 10 Cm X 3 M , Cast Padding 15 Cm X 3 M , Adhesive Hospital Tube 2.5 Cm X 8 M , Adhesive Hospital Tube 5 Cm X 8 M , Adhesive Hospital Tube 7.5 Cm X 8 M , Adhesive Hospital Tube 10 Cm X 8 M , Adhesive Hospital Tube Classic 2.5 Cm X 9 M , Adhesive Hospital Tube Classic 5 Cm X 9 M , Adhesive Hospital Tube Classic 7.5 Cm X 9 M , Adhesive Hospital Tube Classic 10 Cm X 9 M , Adhesive Tape Spool 1.25 Cm X 1 M X 1 Spool , Adhesive Tape Spool 2.5 Cm X 1 M X 1 Spool , Adhesive Tape Spool 2.5 Cm X 5 M X 1 Spool , Adhesive Tape Spool 5 Cm X 5 M X 1 Spool , Adhesive Tape Spool 7.5 Cm X 5 M X 1 Spool , Adhesive Tape Spool 10 Cm X 5 M X 1 Spool , Microporus Hypoallergenic Non Woven Tape 1.25 Cm X 9 Mtr , Microporus Hypoallergenic Non Woven Tape 2.5 Cm X 9 Mtr , Microporus Hypoallergenic Non Woven Tape 5 Cm X 9 Mtr , Microporus Hypoallergenic Non Woven Tape 7.5 Cm X 9 Mtr , Microporus Hypoallergenic Non Woven Tape 10 Cm X 9 Mtr , Gamjee Roll Non Sterile 10 Cm X 2.7 M , Gamjee Roll Non Sterile 15 Cm X 2.7 M , Medicated Dressing (Band-Aid Strips) Regular 70 Mm X 19 Mm - Box(100Pcs) , Medicated Dressing (Band-Aid Strips) Wash Proof 70 Mm X 19 Mm - Box(100 Pcs) , Medicated Dressing (Band-Aid) Spot 22Mm - Box(200 Pcs) , Belladonna Plaster 17 Cm X 11 Cm , Capsicum Plaster 17 Cm X 11 Cm , Corn Cap 22 Mm X 70 Mm X 4S , Gauze Swab T-17 - 5 Cm X 5 Cm X 8 Ply , Gauze Swab T-17 - 7.5 Cm X 7.5 Cm X 8 Ply , Gauze Swab T-17 - 10 Cm X 10 Cm X 8 Ply , Paraffin Gauze Dresssing 10 Cm X 10 Cm X 1S , Paraffin Gauze Dresssing 10 Cm X 10 Cm X 10S , Paraffin Gauze Dresssing 10 Cm X 10 Cm X 20S Tin , Paraffin Gauze Dresssing 10 Cm X 30 Cm X 1S , Chlorhexidine Gauze Dresssing 10 Cm X 10 Cm X 1S , Chlorhexidine Gauze Dresssing 10 Cm X 10 Cm X 10S , Chlorhexidine Gauze Dresssing 10 Cm X 30 Cm X 1S , Combine Dressing 10 Cm X 10 Cm X 1S , Combine Dressing 10 Cm X 20 Cm X 1S , X-Ray Detectable Abdominal Pad 25 Cm X 25 Cm X 8 Ply , X-Ray Detectable Abdominal Pad 25 Cm X 40 Cm X 8 Ply , X-Ray Detectable Abdominal Pad 25 Cm X 25 Cm X 12 Ply , X-Ray Detectable Abdominal Pad 30 Cm X 30 Cm X 10 Ply , X-Ray Detectable Abdominal Pad 30 Cm X 30 Cm X 12 Ply , Plaster Of Paris Bandage 7.5 Cm X 2.7 Mtr , Plaster Of Paris Bandage 10 Cm X 2.7 Mtr , Plaster Of Paris Bandage 15 Cm X 2.7 Mtr , Kinesiology Tape , Elastic Adhesive Bandage 8 Cm X 1 Mtr , Elastic Adhesive Bandage 8 Cm X 2/3 Mtr , Elastic Adhesive Bandage 8 Cm X 4/6 Mtr - Tin , Elastic Adhesive Bandage 10 Cm X 1 Mtr , Elastic Adhesive Bandage 10 Cm X 2/3 Mtr , Elastic Adhesive Bandage 10 Cm X 4/6 Mtr-Tin , Rigid Athletic Tape 1 X 15 Yd , Rigid Athletic Tape 1.5 X 15 Yd , Rigid Athletic Tape 2 X 15 Yd , Premium Rigid Athletic Tape 1.5 X 15 Yd , Premium Rigid Athletic Tape 2 X 15 Yd , Rigid Strapping Tape 1 X 15 Yd - Brown , Rigid Strapping Tape 1 X 15 Yd - White , Rigid Strapping Tape 1.5 X 15 Yd - Brown , Rigid Strapping Tape 1.5 X 15 Yd - White , Rigid Strapping Tape 2 X 15 Yd , Economy Rigid Athletic Tape 1.5 X 15 Yd , Porous Rigid Athletic Tape 1.5 X 15 Yd , Zinc Oxide Rigid Athletic Tape 1 X 10.9 Yd , Zinc Oxide Rigid Athletic Tape 1.5 X 10.9 Yd , Zinc Oxide Rigid Athletic Tape 2 X 10.9 Yd , Rigid Cohesive Bandage 1.5 X 15 Yd , Elastic Strapping Tape 1.5 X 7.5 Yd , Lightweight Elastic Adhesive Bandage 1.5 X 7.5 Yd , Lightweight Elastic Adhesive Bandage 2 X 5 Yd , Lightweight Elastic Adhesive Bandage 2 X 7.5 Yd , Lightweight Elastic Adhesive Bandage 3 X 5 Yd , Lightweight Elastic Adhesive Bandage 3 X 7.5 Yd , Elastic Adhesive Sports Tape 2 X 7.5 Yd , Elastic Adhesive Sports Tape 3 X 7.5 Yd , High-Strength Elastic Adhesive Bandage 1 X 5 Yd , High-Strength Elastic Adhesive Bandage 2 X 5 Yd , High-Strength Elastic Adhesive Bandage 3 X 5 Yd , Elastic Adhesive Bandage 2 X 5 Yd , Elastic Adhesive Bandage 3 X 5 Yd , Elastic Adhesive Bandage 4 X 5 Yd , Cohesive Elastic Bandage 1 X 6Yd , Cohesive Elastic Bandage 2 X 6Yd , Cohesive Elastic Bandage 3 X 6Yd , Cohesive Elastic Bandage 4 X 6Yd , Cohesive Elastic Bandage 6 X 6Yd , Cohesive Compression Bandage , Cohesive Stretch Wound Compression Tape 2 X 5 Yd , Cohesive Compression Bandage 3 X 5 Yd , Plantar Fasciitis Support Tape | Reg - 7 Applications , Finger Protection Tape , Foam Underwrap Tape , Prewrap - Underwrap Paper , Adhesive Abrasion Protection Tape Roll 2 X 10 Yd , Adhesive Abrasion Protection Tape Roll 4 X 10 Yd , Adhesive Abrasion Protection Tape Roll 6 X 10 Yd , Dynamic Tape , Fixomull , Foam Padding With Adhesive , Silicon Gel Sheet , Moleskin Padding Roll - 24 X 4 5/8 , Latex-Free Moleskin - 1 X 5 Yd , Latex-Free Moleskin - 2 X 5 Yd , Silicone Scar Tape Roll - 1.6 X 60 , Medical Silicone Tape - 2Cm X 1.5Mtr , Mouthguard W/O Strap , Mouthguard With Strap , Ice Bag 9 , Cotton Roll Pack Small , Cotton Roll Pack Big , Cotton Bandage 4” , Cotton Bandage 6” , Band Aid Strips Box(100Pc) , Tape Adherant Spray , Tape Remover Spray , Skin On Skin Spenco 200Pc , Adhesive Felt Pad 5 Cm X 5 Cm (Pck Of 5) , Adhesive Felt Pad 10 Cm X 10 Cm (Pck Of 5) , Precut Adhesive Felt Pad 5 X 5 Cm With 2.5 Cm Diameter Hole (Pck Of 5) , Precut Adhesive Felt Pad 10 X 10 Cm With 4 Cm Diameter Hole (Pck Of 5) , Precut Adhesive Felt Pad 10 X 10 Cm With 5.5 Cm Diameter Hole (Pck Of 5) , Generic Scissiors – 6 Ss , Generic Scissiors – 8 Non Stick , Angled Taping Scissiors – Standard - Ss , Angled Taping Scissiors – Standard - Non Stick , Angled Taping Scissiors – Premium - Ss , Angled Taping Scissiors – Premium - Non Stick , Angled Bandage Scissors , Kinesiology Scissors , Volini Spray 60Ml , Volini Gel 30Gm , Drez Spray 40Gm , Neck & Back Pain Relief Patches Heat Wraps - 10 Count , Vicks Vaporub Chest Rub & Balm - 50Gm , Mistress Spray , Relispray Nitron Cool Spray , Deep Freeze Spray , Deep Freeze Gel , Deep Heat Spray , Deep Heat Gel , Sweatblock Antiperspirant Lotion For Hands & Feet – 50Ml , Sweat Block Antiperspirant Gel For Face – 50G , Magnesium Oil Spray , Fitogal Horse Balsam , Betadine Solution 100Ml , Betadine Oinment 20 Gm , Silverex Ionic Gel/ Soframycin - 20Gm , Sevlon Liquid 100Ml , Dettol Antiseptic Liquid - 250 Ml , Mycoderm Antiseptic Powder - 150 Gm , Instant Bleeding Stopper Powder , Steri-Strip - 6 Mm X 100 Mm, Pack Of 10 , Silicone Foam Wound Dressing 10X10cm – Sterile, Waterproof, Pack Of 5 , Spirit (Isopropyl Alcohol 99.9% Pure) - 300 Ml , Hand Sanitizer Gel - 55 Ml , Hand Sanitizer Liquid - 500 Ml , Alco Swab Alcohol Gauze Box - 100Pc , Hand Sanitizer Dispenser - 2 L , Hand Sanitizer Dispenser - 1 L , Germ Protection Wet Wipes Pack , Wet Wipes , Ultra Sound Gel - 250 Ml , Ultra Sound Gel - 5 Ltr. , Massage Cream Naqi 500Ml , Massage Cream Uk Sports , Olivia Massage Cream , Blue Nitrile Examination Gloves Box - 100Pcs , Latex Medical Examination Hand Gloves Box - 100 Pcs , Pre-Sterilized Surgical Skin Marker Set - 10Pcs , Disposable Mask Pack - 25 Pcs , Disposable Shoe Cover - 100 Pairs , Pocket Cpr Mask/Cpr Kit , Disposable Bedsheet Non-Woven Fabric (White, 35X72inch, 30 Gsm) - 100 Pcs , Tissue Paper Napkin , Toilet Tissue Roll , Reusable Non-Woven Kitchen Towels Roll , Tissue Paper Roll , Tissue Paper Napkins Pull Box , Face Tissue Box , Cloth Napkin - 45Cm X 45 Cm , Hand Towel , Body Towel , Microfiber Cleaning Cloth , Reusable Zip Lock Storage Bags - 45 Count (15 Each - S, M, L) , Eco-Friendly Garbage Bags - 1 Roll (15 Bags, 24 X 32) , Wheel Chair - Basic , Wheel Chair - Heavy Duty Steel , Wheel Chair - Premium , Powered Wheel Chair - Basic , Powered Wheel Chair - Premium , Walking Stick , Walking Stick - L Type , Walking Stick - Folding , Walking Stick - Quadripod , Walking Stick - Tripod , Elbow Crutch - Adjustable , Axillary Crutch (Pair) , Walker - Basic , Walker - Premium , Walker - Front Wheels , Hernia Belt , Stockinette 10Mtr - 5Cm , Stockinette 10Mtr - 7.5Cm , Stockinette 10Mtr - 10Cm , Stockinette 10Mtr - 12.5Cm , Stockinette 10Mtr - 15Cm , Compression Sleeve - Arm , Compression Sleeve - Calf And Shin , Compression Sleeve - Thigh , Air Mattress , Finger Cot Splint , Thumb Spika , Scortal Support , Silicone Heel Gel Sleeve Pair , Soft Gel Finger Tube (Length 6 X Diameter-0.59) , Heel & Lace Pads Box - 2000 Pcs , Silicone Foot Arch Support , Sitting Wedge , Analogue Upper Arm Blood Pressure Monitor , Oconnor Tweezer Dexterity Test By Oconnor , Distance Measuring Laser Tool – 150M , Distance Measuring Laser Tool – 100M , Distance Measuring Laser Tool – 50M , Kestrel Pocket Wind Meter , Babinski Reflex Hammer , Lactate Testing Kit , Lactate Test Strips - 25 , Moist Pack Set (4Pcs) , Reusa/Eu/Australiable Hot And Cold Ice Gel Pack With Adjustable Strap , Hydrocollator Unit , Cupping Set , Mini Pedal Exerciser With Resistance Adjustment & Digital Display , 40 Foldable Trampoline Rebounder , 45” Trampoline Rebounder With Adjustable Handle , 50 Trampoline Rebounder With Adjustable Handle , Jumping Trampoline With Enclosure Net - 16 Ft. , Exercise Gym Ball Base With Resistance Band Handle , Portable Hand Pump , Portable Foot Pump , Balance Pods , Sport Balance Trainer , Exercise Balance Pad , Hot And Cold Eyes Mask , Cool Eyes , Adjustable Aerobic Stepper , Mulligan Mobilization Belt , Peripheral Drop , Chiropractic Adjusting Tool - Standard , Chiropractic Adjusting Tool - Expert , Chiropractic Adjusting Tool - Pro Select , Vicks Inhaler , Candid Dusting Powder - 250 Gm , Candid Activ Talc - 100 Gm , Disposable Manual Shaving Razor - 10 Pcs Pack , Coagulant Spray , Battery 1.5V Aa , Battery 1.5V Aaa , Battery 9V , Torch Light , Emergency Rechargeable Led Lantern , Hair Dryer , Mosquito Bat , Hit Spray Flying Insect Killer , Room Spray , Velcro Straps Set (Small, Medium, Large) , Whistles With Lanyard , Compass For Directions , Silicone Ice Tray , Olive Oil – 1L , Olive Oil – 5L , Paraffin Wax (Slab) – 1 Kg , Paraffin Wax (Pellets) – 500Gm , Podiatry Kit , Oxygen Concentrator - 5Lpm , Portable Oxygen Can Pack - 6L With Mask, Tube & Elastic Strap , Yoga Mat 4Mm , Yoga Mat 6Mm , Yoga Mat 8Mm , Yoga Mat 10Mm , Gym Mat - 6 Mm - 36”X75” , Foam Roller (12) , Foam Roller (18) - Plain , Foam Roller (18) - Textured , Foam Roller (36) , Foam Roller Half Round (36) , Foot Roller Green Apac , Green Roller Massager , Portable Roller Massager , Yoga Belt / Strap - White , Yoga Block / Bricks Eva - Big 6 X 9 X 3 , Yoga Block / Bricks - Small 4 X 9 X 3 , Wooden Massager Stick - 10 Beads , Wooden Massager Stick - 20 Beads , Peanut Shaped Massage Ball , Wooden Body Massager With Accu Wheels , Wooden 6 Ball Pain Relife Roller , 4 Wheel Wooden Soft Roller , Acupressure Wooden Ball , Acupressure Wooden Roller - Big , Acupressure Wooden Roller - Small , Kansya Wand Wooden Massager Jimmy - Big Bronze , Kansya Wand Wooden Massager Jimmy - Small Bronze , Bolster , Acupressure Beak Roller - Wooden , Acupressure Beak Roller - Plastic , Acupressure Mat Block - Wooden , Acupressure Mat Block - Super With Copper , Acupuncture Needles With Tube 13Mm , Acupuncture Needles With Tube 25Mm , Acupuncture Needles With Tube 40Mm , Acupuncture Needles With Tube 50Mm , Acupuncture Needles With Tube 60Mm , Acupuncture Needles With Tube 75Mm , Acupuncture Needles With Tube 100Mm , Acupuncture Needles With Tube 125Mm , Foam Plyometric Box (20 X 24 X 30) , Foam Plyometric Box Set Of 4 (6, 12, 18, 24) , Wooden Plyometric Box S (12 X 14 X 16) , Wooden Plyometric Box M (16 X 20 X 24) , Wooden Plyometric Box L (20 X 24 X 30) , Wobble Board For Standing Anti-Fatigue Foam Pad , Wobble Wooden Balance Board - Circular , Rocker Wooden Balance Board - Rectangular - 180* , Rocker Wooden Balance Board - Rectangular - 360* , Balance Board Trainer Wooden - Skate , Interlocking Exercise Foam Mats -120Sqft (30Tile) , Rubber Tile 20 X 20 X 10Mm , Rubber Tile 20 X 20 X 20Mm , Exercise Mat - 25Mm X 75Cm X 180Cm , Gym Mat - 50Mm X 90Cm X 180Cm , Combat Mat - 55Mm X 2 Mtr X 1 Mtr , Crash Mat - 18 X 6’ X 4’ , Dumbbell Vinyl - 0.5 Kg , Dumbbell Vinyl - 1 Kg , Dumbbell Vinyl - 1.5 Kg , Dumbbell Vinyl - 2 Kg , Dumbbell Vinyl - 3 Kg , Dumbbell Vinyl - 4 Kg , Dumbbell Vinyl - 5 Kg , Dumbbell Vinyl - 7.5 Kg , Dumbbell Vinyl - 10 Kg , Medicine Ball - 1Kg , Medicine Ball - 2Kg , Medicine Ball - 3Kg , Medicine Ball - 4Kg , Medicine Ball - 5Kg , Medicine Ball - 6Kg , Medicine Ball - 7Kg , Medicine Ball - 8Kg , Medicine Ball - 9Kg , Medicine Ball - 10Kg , Weight Cuff - 0.5 Kg , Weight Cuff - 1 Kg , Weight Cuff - 1.5 Kg , Weight Cuff - 2 Kg , Weight Cuff - 3 Kg , Weight Cuff - 4 Kg , Weight Cuff - 5 Kg , Rack For 6 Dumbbell Vinyls , Rack For 6 Medicine Balls , Adjustable Kettlebell With 6 Plates (5 Lbs Each) , Kettlebell Rack - 49?X19?X40? - Capacity 350Kg , Kettlebell - 2 Kg , Kettlebell - 4 Kg , Kettlebell - 6 Kg , Kettlebell - 8 Kg , Kettlebell - 12 Kg , Kettlebell - 16 Kg , Kettlebell - 20 Kg , Kettlebell - 24 Kg , Kettlebell - 28 Kg , Kettlebell - 32 Kg , Kettlebell - 40 Kg , Index Knobber W/ Cone , Index Knobber W/ Cap , Index Knobber W/ Ball , Index Knobber Pressure Tool Set (Wood) , Index Knobber Ii , Knobble , Knobble Ii , Jacknobber , Jacknobber Ii , Backnobber , Backnobber Ii , Vibrassager , Palmassager , Orbitmassager , Intraoral Tmj Trigger Point Release Tool , Hip Wrap With Hot/Cold Therapy And Trigger Point Massage , Knee Joint Model With Flexible Ligaments , Hip Joint Model With Ligaments , Shoulder Joint Model With Ligaments , Foot Joint Model With Ligaments , Hand Joint Model With Ligaments , Human Joint Models Set Of 5 - (Knee, Hip, Shoulder, Foot, Hand) , Elbow Joint Model With Ligaments , Human Spine Model With Pelvis, Nerves & Stand – Flexible With Herniated Disc , Ice Box - 4.5L , Ice Box - 26L , Ice Box - 28L , Ice Box - 45L , Ice Box - 49L , Ice Box - 52L , Ice Box - 66L , Ice Box - 10L Bag , Ice Box - 47L With Wheels , Ice Box - 56L With Wheels , Ice Box - 61L With Wheels , Ice Box - 94L With Wheels , Compact Ppe Waist Pack , Athletic Trainer Waist Pack , Modular Storage Pack , Sideline Sling Response Bag , Large Modular Storage Pack , Medical Utility Bag , Emergency Response Medical Bag , Athletic Trainer Briefcase , Compact Medical Supply Bag , Medium Medical Supply Bag , Athletic Trainer Shoulder Bag , Premium Medical Supply Bag , Versatile Medical Response Bag , Customizable Large Medical Bag , Large Multi-Use Roller Bag , Medical Device Roller Bag , Large Medical Supply Bag , Extra-Large Medical Supply Bag , Mat - Foldable Ruler , Functional Hop Test And Jump Assessment Mat – 600Cm × 20Cm , Functional Movement & Balance Assessment Mat – Sebt, Ybt, Ckcue, Wblt, Squat & Lunge Testing Tool , Hand Evaluation - 3-Piece Set - Features Lite 200 Lb Hydraulic Hand Dynamometer & 50 Lb Hpg , Hand Evaluation - 7-Piece Set - Features Lite 200 Lb Hydraulic Hand Dynamometer & 30 Lb Mpg , Hand Evaluation - 3-Piece Set - Features Standard 200 Lb Hydraulic Hand Dynamometer & 50 Lb Hpg , Hand Evaluation - 3-Piece Set - Features Hires, Large Head, Hand Evaluation Set (Dyna, Pinch, Gonio) , Hand Evaluation - 7-Piece Set - Features Digital Lcd Er 300 Lb Hydraulic Hand Dynamometer & 60 Lb Mpg , Wrist Evaluation - 4-Piece Set - Features 500 Lb , Hand Evaluation - 3-Piece Set - Features Hd 200 Lb Hydraulic Hand Dynamometer & 50 Lb Hpg , Hand Evaluation - 7-Piece Set - Features Hd 200 Lb Hydraulic Hand Dynamometer & 30 Lb Mpg , Hand Evaluation - 8-Piece Set - Sensory Evaluators (Baseline/Touch-Test) , Hand Evaluation - 8-Piece Set - Features Lite 200 Lb Hydraulic Hand Dynamometer & 50 Lb Hpg , Hand Evaluation - 8-Piece Set - Features Hd 200 Lb Hydraulic Hand Dynamometer & 50 Lb Hpg , Hand Evaluation - 8-Piece Set - Features Standard 200 Lb Hydraulic Hand Dynamometer & 50 Lb Hpg , Hand Evaluation - 8-Piece Set - Sensory Evaluators , Pinch Gauge - Mechanical - Blue - 30 Lb Capacity , Pinch Gauge - Mechanical - Red - 60 Lb Capacity , Pinch Gauge - Mechanical - Gold - 2 Lb Capacity , Pinch Gauge - Mechanical - Silver - 10 Lb Capacity , Hand Dynamometer - Hd - 200 Lb Capacity , Pinch Gauge - Hydraulic - Hd - 50 Lb Capacity , Pinch Gauge - Hydraulic - Lite - 50 Lb Capacity , Pinch Gauge - Hydraulic - Hires Gauge - Er 100 Lb , Pinch Gauge - Hydraulic - Standard - 50 Lb Capacity , Pinch Gauge - Hydraulic - Digital Lcd Gauge - Er , Pinch Gauge - Hydraulic - 100 Lb Analog Output , Pinch Gauge - Hydraulic - Hires Gauge - 50 Lb , Hand Dynamometer - Standard - 200 Lb Capacity , Hand Dynamometer - Lite - 200 Lb Capacity , Hand Dynamometer - Hires Gauge - 200 Lb , Hand Dynamometer - Hires Gauge - Er 300 Lb , Hand Dynamometer - Digital Lcd Gauge - Er 300 Lb , Hand Dynamometer - 300 Lb Analog Output Signal, , Wrist Dynamometer - Analog 500 Lb Capacity, With Knob Grip & Mount Bracket , Wrist Dynamometer - Digital Lcd 500 Lb Capacity, With Knob Grip & Mount Bracket , Hand Dynamometer - Accessory - Case Only For Standard And Digital Gauge , Hand Dynamometer - Accessory - Case Only For , Wrist Dynamometer - Accessory - Knob Grip Handle , Wrist Dynamometer - Accessory - Shovel Handle , Wrist Dynamometer - Accessory - Lever Handle , Wrist Dynamometer - Accessory - Rod Handle , Wrist Dynamometer - Accessory - Mounting Bracket For Tabletop Or Wall , Wrist Dynamometer - 500 Lb Capacity Analog Output Signal, No Gauge , Hand Dynamometer - Standard 200 Lb Capacity - Reverse Gauge Exercise/Feedback Model , Pinch Gauge - Hydraulic - Standard - 50 Lb Capacity - Reverse Facing Gauge , Smedley Spring Dynamometer, Adult, 220 Lb. , Smedley Spring Dynamometer, Child, 110 Lb. , Smedley Digital Hand Dynamometer , Dynamometer - Pneumatic Squeeze Bulb - 30 Psi Capacity, No Reset , Dynamometer - Pneumatic Squeeze Bulb - 30 Psi Capacity, With Reset , Dynamometer - Pneumatic Squeeze Bulb - 15 Psi Capacity, No Reset , Dynamometer - Pneumatic Squeeze Bulb - 15 Psi Capacity, With Reset , Dynamometer - Pneumatic 3-Bulb Combo Kit - 30 Psi Capacity, With Reset , Manual Muscle Tester - Mechanical - Includes 3 Push, 2 Pull Attachments - 2.2 Lb Capacity , Manual Muscle Tester - Mechanical - Includes 3 Push, 2 Pull Attachments - 5 Lb Capacity , Manual Muscle Tester - Mechanical - Includes 3 Push, 2 Pull Attachments - 10 Lb Capacity , Manual Muscle Tester - Mechanical - Includes 3 Push, 2 Pull Attachments - 60 Lb Capacity , Manual Muscle Tester - Mechanical - Includes 3 Push, 2 Pull Attachments - 22 Lb Capacity , Manual Muscle Tester - Electronic - Includes 3 Push, 2 Pull Attachments - 50 Lb Capacity , Manual Muscle Tester - Electronic - Includes 3 Push, 2 Pull Attachments - 100 Lb Capacity , Manual Muscle Tester - Electronic - Includes 3 Push, 2 Pull Attachments - 250 Lb Capacity , Manual Muscle Tester - Electronic - Includes 3 Push, 2 Pull Attachments - 500 Lb Capacity , Gauge Tester With Push-Pull Dynamometer , Manual Muscle Tester - Accessory - Small Curved Push Pad , Manual Muscle Tester - Accessory - Straight Push Pad , Manual Muscle Tester - Accessory - Large Curved Push Pad , Manual Muscle Tester - Accessory - Small Flat Circular Push Tip , Manual Muscle Tester - Accessory - Small Pull Hook , Manual Muscle Tester - Accessory - Medium Pull Hook , Manual Muscle Tester - Accessory - Threaded Oval Spring Hook , Manual Muscle Tester - Accessory - Single Grip Handle , Manual Muscle Tester - Hydraulic - Includes 3 Push, 2 Pull Attachments - Digital Lcd Gauge - 500 Lb Capacity , Manual Muscle Tester - Hydraulic - Includes 3 Push, 2 Pull Attachments - Analog Gauge - 500 Lb Capacity , Manual Muscle Tester - Accessory - Dual Grip Handle (Also For Wrist , Manual Muscle Tester - Hydraulic - Includes 3 Push, 2 Pull Attachments - Analog Gauge - 50 Lb Capacity , Manual Muscle Tester - Hydraulic - Includes 3 Push, 2 Pull Attachments - Analog Gauge - 100 Lb Capacity , Manual Muscle Tester - Hydraulic - Includes 3 Push, 2 Pull Attachments - Analog Gauge - 250 Lb Capacity , Manual Muscle Tester - Hydraulic - Includes 3 Push, 2 Pull Attachments - Digital Lcd Gauge - 50 Lb Capacity , Manual Muscle Tester - Hydraulic - Includes 3 Push, 2 Pull Attachments - Digital Lcd Gauge - 100 Lb Capacity , Manual Muscle Tester - Hydraulic - Includes 3 Push, 2 Pull Attachments - Digital Lcd Gauge - 250 Lb Capacity , Back-Leg-Chest Dynamometer - Standard Platform - 660 Lb Capacity , Back-Leg-Chest Dynamometer - Standard Platform - 330 Lb Capacity , Back-Leg-Chest Dynamometer - Standard Platform - 165 Lb Capacity , Back-Leg-Chest Dynamometer - Oversize Platform - 660 Lb Capacity , Back-Leg-Chest & Manual Muscle Tester Accessory - Standard Lifting , Back-Leg-Chest & Manual Muscle Tester Accessory - Oversize Lifting , Cable Tensiometer - 660 Lb Capacity , Cable Tensiometer - 330 Lb Capacity , Cable Tensiometer - 165 Lb Capacity , Manual Muscle Tester - Accessory - Single Grip , Manual Muscle Tester - Accessory - Ankle Cuff , Manual Muscle Tester - Accessory - Thigh Cuff , Manual Muscle Tester - Accessory - Wrist Cuff , Manual Muscle Tester - Accessory - Shoulder Harness , Back-Leg-Chest Dynamometers Accessory - Lifting Chain, 1 Foot Length , Back-Leg-Chest & Manual Muscle Tester Accessory - Snap Oval For Lifting Platform , Back-Leg-Chest & Manual Muscle Tester Accessory - Threaded Oval For Manual Muscle Tester Connection , Manual Muscle Tester - Accessory - 7-Piece Pack With 3 Push And 4 Pull Accessories , Electronic Pinch Gauge , Pinch Gauge - Hydraulic - 5-Level Pinch Clinic Mode - 50 Lb Capacity , Pinch Gauge - Hydraulic - 5-Level Pinch Feedback Mode - 50 Lb Capacity , Wrist Inclinometer , Hydraulic Hand Dynamometer To Manual Muscle Tester Combo - Push Attachments Only , Hydraulic Hand Dynamometer To Manual Muscle Tester Combo - Dual Handle Only , Hydraulic Hand Dynamometer To Manual Muscle Tester Combo - Lite Hydraulic Hand Dynamometer With Push , Hydraulic Hand Dynamometer To Manual Muscle Tester Combo - Standard Hydraulic Hand Dynamometer With Push , Hydraulic Hand Dynamometer To Manual Muscle Tester Combo - Hd Hydraulic Hand Dynamometer With Push , Hydraulic Hand Dynamometer To Manual Muscle Tester Combo - Lite Hydraulic Hand Dynamometer With Push Attachments And Dual Handle , Hydraulic Hand Dynamometer To Manual Muscle Tester Combo - Standard Hydraulic Hand Dynamometer With Push Attachments And Dual Handle , Hydraulic Hand Dynamometer To Manual Muscle Tester Combo - Hd Hydraulic Hand Dynamometer With Push Attachments And Dual Handle , Wall Growth Chart , Plastic Goniometer - 360 Degree Head - 12 Inch , Plastic Goniometer - 360 Degree Head - 8 Inch , Plastic Goniometer - 360 Degree Head - 6 Inch , Plastic Goniometer - Pocket Style - 180 Degree , Plastic Goniometer - Rulongmeter Style - 360 Degree Head - 6 Inch Arms , Finger Goniometer - Metal - Standard - 6 Inch , Finger Goniometer - Metal - Deluxe - 6 Inch , Plastic Goniometer - Finger - Flexion To Hyper- , Finger Goniometer - Plastic - 1-Finger Design - 6 , Finger Goniometer - Metal - Small - 3.5 Inch , Finger Goniometer - Metal - 1-Finger Design - 6 Inch , Metal Goniometer - 180 Degree Range - 18 Inch , Plastic Absolute+Axis Goniometer - 360 Degree Head - 12 Inch Arms , Plastic Absolute+Axis - Attachment Only For 12 Inch , Metal Absolute+Axis Goniometer - Digital 180 Degree Range, 9 Inch Arms , Plastic Goniometer - 6-Piece Set , Hi-Res Measuring Set (1 Ea: 8, 12 360 Goniometer, 6 Pocket Goniometer, 60 Tape) , X-Ray Radiopaque Goniometer - 180 Degree Range - , X-Ray Radiopaque Goniometer - 180 Degree Range - , X-Ray Radiopaque Goniometer - 180 Degree Range - , Metal Goniometer - 180 Degree Range - 8 Inch Legs , Metal Goniometer - 180 Degree Range - 14 Inch , Metal Goniometer - 180 Degree Range - 6 Inch Legs - , Metal Goniometer - 6-Piece Set , Digital Plastic 360 Degree 10 Inch Goniometer , Metal Goniometer - 360 Degree Range - 14 Inch , Gravity Inclinometer , Bubble Inclinometer , Digital Inclinometer , Functional Finger Motion Gauge , Universal Inclinometer With Clip , Universal Inclinometer With Headband , Large Joint Protractor , Posture Evaluation - 2-Piece Set - Evaluator And , Posture Evaluator , Posture Grid , Posture Evaluation - 3-Piece Set - Protractor, , Sit N Reach Trunk Flexibility Box , Sit N Reach Trunk Flexibility Box - Deluxe , Body Level , Scoliosis Meter - Metal , Isom Measurement Chart , Adjustable Wall Goniometer , Scoliosis Meter - Plastic Economy , Medical Skinfold Caliper , Economy Plastic Skinfold Caliper , Skinfold Caliper - Accessory - Calibration Block Only , Economy Plastic Skinfold Caliper, Slim-Guide Style , Medical Skinfold Caliper - Deluxe Dual-Sided Model , Hand-Held Body Fat Monitor (Metric Only) , Hand-Held Body Fat Analyzer - Palm-Size - Baseline , Credit-Card Style Body Fat Analyzer , Acuangle Adjustable-Feet Inclinometer , Scale - Body Fat Scale , Measurement Tape With Gulick Attachment, 60 Inch , Measurement Tape With Gulick Attachment, 72 Inch , Measurement Tape With Gulick Attachment, 120 , Measurement Tape With Hands-Free Attachment, , Measurement Tape, 60 Inch , Measurement Tape, 72 Inch , Measurement Tape, 120 Inch , Finger Circumference Gauge, 6 Inch Maximum , Finger Circumference Gauge, 15 Cm Maximum , Finger Circumference Gauge, 6 Inch / 15 Cm , Multi-Filament Pen, 4 Monofilament Sizes , Monofilament - Retracting Filament - 1 Gram , Monofilament - Retracting Filament - 10 Gram , Monofilament - Retracting Filament - 100 Gram , Monofilament - Retracting Filament - 3-Piece Set (1,10 And 100 Gram) , Folding Monofilament, 1 Gram , Folding Monofilament, 10 Gram , Folding Monofilament, 100 Gram , Folding Monofilament, 3-Piece Set (1, 10, 100) , Dolorimeter - 2 Pound Capacity , Dolorimeter - 5 Pound Capacity , Dolorimeter - 22 Pound Capacity , Dolorimeter - 60 Pound Capacity , Dolorimeter - 10 Pound Capacity , Cleanwheel Sterile Disposable Neurological , Cleanwheel Non-Sterile Disposable Neurological , Aesthesiometer - Plastic - 2-Point Discriminator , Aesthesiometer - Plastic - 2-Point Discriminator , Aesthesiometer - Stainless Steel - 2-Point , 2-Point Disk-Criminator, 2 Disk Set, Metal Tips , 2-Point Discrim-A-Gon, 2 Disk Set, Plastic Tips , Multi-Setting Two-Point Discriminator , Tactile Monofilament - Protective Case - 2 , Tactile Monofilament - Protective Case - 6 , Tactile Monofilament - Protective Case - 24 , Tactile Monofilament - 2-Piece Set - Normal - 2.83, , Tactile Monofilament - 5-Piece Set - Hand - 2.83, 3.61, 4.31, 4.56, 6.65 Gram , Tactile Monofilament - 6-Piece Set - Foot - 2.83, 3.61, 4.31, 4.56, 5.07, 6.65 Gram , Tactile Monofilament - 20-Piece Set - Complete , Tactile Monofilament - 2-Piece Set - Protective Sensation - 4.56, 5.07 Gram , Tactile Monofilament - Leap Program - Disposable - 5.07 - 10 Gram - Single Unit , Tactile Monofilament - Ada Program - Disposable - 5.07 - 10 Gram - Single Unit , Windmill Type Spirometer , Accessory - 100 Plastic Mouthpieces , Accessory - 500 Paper Mouthpieces , Accessory - 1000 Paper Mouthpieces , Accessory - 250 Paper Mouthpieces , Fold-Up Monofilament, Evaluator Hand Set With Case (Set Of 5: 2.83, 3.61, 4.31, 4.56, 6.65) , Fold-Up Monofilament, Evaluator Foot Set With Case (Set Of 6: 2.83, 3.61, 4.31, 4.56, 5.07, 6.65) , Fold-Up Monofilament, Evaluator Set With Case (Set Of 20: 1.65 Through 6.65) , Fold-Up Monofilament, Normal Limit Set , Fold-Up Monofilament, Protective Sensation (Set) , Fingertip Pulse Oximeter, Standard , Fingertip Pulse Oximeter, Deluxe , Fingertip Pulse Oximeter, Pediatric , Fingertip Pulse Oximeter, Taa Compliant , Lite Pedometer, Step Only, Includes Strap , Standard Pedometer, Step, Distance & Calorie , Deluxe Pedometer, Step, Distance, Calorie, Activity Time, Includes Strap , Bims Digital 5-Position Grip Dynamometer, Clinic , Bims Digital 5-Position Grip Dynamometer, Deluxe , Bims Digital 5-Position Pinch Dynamometer, Clinic , Bims Digital 5-Position Pinch Dynamometer, Deluxe , Bims Digital 5-Position Dynamometer, 3-Piece Hand Evaluation Set, Clinic Model , Bims Digital 5-Position Dynamometer, 3-Piece Hand Evaluation Set, Deluxe Model , Bims Digital 5-Position Dynamometer, 3-Piece Hand Evaluation Set, Functional Model , Hand Dynamometer - 300 Lb Dial Gauge And Analog , Pinch Gauge - Hydraulic - 50 Lb Dial Gauge And Analog Output Signal , Wrist Dynamometer - 500 Lb Capacity Dial Gauge & Analog Output Signal , 24-Hour Combination Stopwatch/Clock , Wristwatch Blood Pressure And Pulse Monitor , Electronic Blood Pressure Monitor , 9 Hole Pegboard , Volumetric Measuring Device - Hand Set, 3X5x9 Inch , Volumetric Measuring Device - Arm Set, 7X7x30 Inch , Volumetric Measuring Device - Foot Set, 5X13x9 Inch , Volumetric Measuring Device - Forearm Set, 6X6x24 , Volumetric Measuring Device - Partial Leg Set , Volumetric Measuring Device - Large Partial Leg Set, 8X13x16 Inch Cavity , Pinch Gauge - Hydraulic - 5-Level Pinch - Additional , Plastic Goniometer - Hires 360 Degree Head - 12 , Plastic Goniometer - Hires 360 Degree Head - 8 , Plastic Goniometer - Hires 360 Degree Head - 6 , Plastic Goniometer - Pocket Style - Hires 180 Degree Head - 6 Inch Arms , Plastic Goniometer - Rulongmeter Style - Hires 360 Degree Head - 6 Inch Arms , Plastic Goniometer - Finger - Hires Flexion To Hyper- , Plastic Absolute+Axis Goniometer - Hires 360 Degree Head - 12 Inch Arms , Plastic Goniometer - Hires 6-Piece Set , Xtender Hires 360 Isom Goniometer , Tactile Monofilament - Ada/Leap/Lops - Disposable W/Sleeve - 5.07 - 10 Gram - 1 Ea. , Monitor Exercise Feedback Device , Digital Timer , Whey Gold - 100% Whey Protein Isolate - 30G Protein Per Serving - 1Kg , Whey Gold - 100% Whey Protein Isolate - 30G Protein Per Serving - 2Kg , Whey Gold - 100% Whey Protein Isolate - 30G Protein Per Serving - 4Kg , Whey Protein - Ultra Premium Whey Blend - 25G Protein Per Serving & 5.5G Bcaa - 1Kg , Whey Protein - Ultra Premium Whey Blend - 25G Protein Per Serving & 5.5G Bcaa - 1.8Kg , Whey Protein - Ultra Premium Whey Blend - 25G Protein Per Serving & 5.5G Bcaa - 2Kg , Whey Protein - Ultra Premium Whey Blend - 25G Protein Per Serving & 5.5G Bcaa - 4Kg , Biozyme Iso Zero Low Carb - 27G Protein Per Serving - 1Kg , Biozyme Iso Zero Low Carb - 27G Protein Per Serving - 2Kg , Biozyme Iso Zero Low Carb - 27G Protein Per Serving - 4Kg , Biozyme Performance Whey- 25G Protein Per Sachet - Box Of (5 X 36Gm Sachet) , Biozyme Performance Whey - 25G Protein Per Serving - 1Kg , Biozyme Performance Whey - 25G Protein Per Serving - 2Kg , Biozyme Performance Whey - 25G Protein Per Serving - 4Kg , Biozyme Whey Protein - 25G Protein Per Serving - 1Kg , Biozyme Whey Protein - 25G Protein Per Serving - 2Kg , Biozyme Whey Protein - 25G Protein Per Serving - 4Kg , Biozyme Gold - 26G Protein Per Serving - 1Kg , Biozyme Gold - 26G Protein Per Serving - 2Kg , Biozyme Whey Pr - 30G Protein Per Serving - 1Kg , Biozyme Whey Pr - 30G Protein Per Serving - 2Kg , Fuel One - Lean Muscle Mass - 24G Protein Per Serving - No Maltodextrin - 1Kg , Fuel One - Lean Muscle Mass - 24G Protein Per Serving - No Maltodextrin - 2Kg , Raw Whey Protein 80% - 24G Protein Per Serving - 1Kg , Raw Whey Protein 80% - 24G Protein Per Serving - 2Kg , Raw Whey Protein 80% - 24G Protein Per Serving - 4Kg , Whey Performance - 24G Protein Per Serving - 13 Rich Vitamins - 1Kg , Whey Performance - 24G Protein Per Serving - 13 Rich Vitamins - 2Kg , Whey Performance - 24G Protein Per Serving - 13 Rich Vitamins - 4Kg , 100% Micellar Casein - 24G Protein Per Serving, 5.6G Bcaa - 1Kg , 100% Micellar Casein - 24G Protein Per Serving, 5.6G Bcaa - 2Kg , Whey Energy - 24G Protein Per Serving, No Added Sugar - 1Kg , Whey Energy - 24G Protein Per Serving, No Added Sugar - 2Kg , Biozyme Clear Whey Isolate - 20G Protein Per Serving - 540Gm , 20G Protein Bar - Pack Of 6 , 10G Protein Bar - Pack Of 6 , High Protein Gold Gainer - 27G Protein Per Serving, Mass Gainer, No Added Sugar - 1Kg , High Protein Gold Gainer - 27G Protein Per Serving, Mass Gainer, No Added Sugar - 3Kg , High Protein Gold Gainer - 27G Protein Per Serving, Mass Gainer, No Added Sugar - 5Kg , Weight Gainer - 12G Protein Per Serving, Combination Of Proteins, Carbohydrates And Fats - 1Kg , Weight Gainer - 12G Protein Per Serving, Combination Of Proteins, Carbohydrates And Fats - 2Kg , Weight Gainer - 12G Protein Per Serving, Combination Of Proteins, Carbohydrates And Fats - 3Kg , Weight Gainer - 12G Protein Per Serving, Combination Of Proteins, Carbohydrates And Fats - 5Kg , Carb Blend - 72G Carbs Per Serving, Balanced Glycogen - 3Kg , Bulk Gainer - 17.6G Protein Per Serving, 27 Vitamins And Minerals - 1Kg , Bulk Gainer - 17.6G Protein Per Serving, 27 Vitamins And Minerals - 3Kg , Bulk Gainer - 17.6G Protein Per Serving, 27 Vitamins And Minerals - 5Kg , Mass Gainer Xxl - 18G Protein Per Serving - 1Kg , Mass Gainer Xxl - 18G Protein Per Serving - 2Kg , Mass Gainer Xxl - 18G Protein Per Serving - 3Kg , Mass Gainer Xxl - 18G Protein Per Serving - 5Kg , Super Gainer Black - 12G Protein Per Serving, Digestion & Testo Blend - 1Kg , Super Gainer Black - 12G Protein Per Serving, Digestion & Testo Blend - 2Kg , Super Gainer Black - 12G Protein Per Serving, Digestion & Testo Blend - 3Kg , Super Gainer Black - 12G Protein Per Serving, Digestion & Testo Blend - 5Kg , Fuel One Max Gainer - 1Kg , Fuel One Max Gainer - 3Kg , Biozyme 5 In 1 Multivitamin - 90 Tabs , Testo Surge Black - 60 Tabs , Testo Surge Black - 90 Tabs , Mb-Vite Daily Multivitamin - 30 Tabs , Mb-Vite Daily Multivitamin - 60 Tabs , Mb-Vite Daily Multivitamin - 90 Tabs , Mb-Vite Daily Multivitamin - 120 Tabs , Fish Oil (1000 Mg) - 30 Capsules , Fish Oil (1000 Mg) - 60 Capsules , Fish Oil (1000 Mg) - 90 Capsules , Fish Oil (1000 Mg) - 120 Capsules , Fish Oil (1000 Mg) - 180 Capsules , Fish Oil Gold - 3X Strength - 60 Capsules , Strongher Women Multivitamin - 60 Tabs , Zma - 60 Tabs , L-Arginine - 90 Capsules , Wrathx Pump - 300Gm , Pre Workout Wrathx - 340Gm , Pre Workout Wrathx - 510Gm , Pre Workout 200 Extreme - 3000Mg L-Citrulline, 2000Mg Beta Alanine - 100Gm , Pre Workout 200 Extreme - 3000Mg L-Citrulline, 2000Mg Beta Alanine - 200Gm , Pre Workout Crea Xtreme - 200Gm , Pre-Workout Ripped - 250Gm , Pre Workout Alter Ego - 250Gm , Pre -Workout 200 - 100Gm , Bcaa 2:1:1 Ratio 5000Mg Power - Box Of (7Gm X 28 Sachets) , Bcaa Pro - 240Gm , Bcaa Pro - 250Gm , Bcaa Pro - 450Gm , Bcaa Pro - 500Gm , Bcaa Gold - 450Gm , Creatine Monohydrate - 100Gm , Creatine Monohydrate - 250Gm , Creatine Monohydrate - 280Gm , Creatine Monohydrate - 400Gm , Creapro - 100Gm , Creapro - 250Gm , Citrulline Malate - 100Gm , Eaa 8000 - 340Gm , Eaa 6000 - 250Gm , One Sports Hydra 8 - Rehydration Formula - 5 Electrolytes, Bcaas, Vitamin C And Zinc - 15Tabs , One Sports Hydra 8 - Rehydration Formula - 5 Electrolytes, Bcaas, Vitamin C And Zinc - 20Tabs , One Sports Hydra 8 - Rehydration Formula - 5 Electrolytes, Bcaas, Vitamin C And Zinc - 60Tabs , Sports Energy Gel - 500 Mg Electrolytes, 75 Mg Caffeine, 85 Kcal - 35Gm - Pack Of 5 , Energy Bars - 200Kcal - Pack Of 6 X 40G , L-Glutamine - 5G Of Glutamine Per Serving - 250Gm , Hydr8 Isotonic - Instant Energy Boost, Rapid Rehydration, Faster Recovery - 1Kg , Liquid L-Carnitine - Boosts Cellular Energy, Fat Metabolism & Weight Management - 300Ml , Liquid L-Carnitine - Boosts Cellular Energy, Fat Metabolism & Weight Management - 450Ml , Liquid Carnitine Pro - Triple The Strength, Enhanced Fat Metabolism - 450Ml , Mb Fat Burner Pro - Convert Fat Into Energy, Suppresses Appetite, Boosts Natural Weight Loss - 60 Tablet , Cla 1000 Fat Burner (Conjugated Linoleic Acid Soft Gelatin Capsules) - 90 Capsules , L-Carnitine L-Tartrate - 30 Capsules , L-Carnitine L-Tartrate - 60 Capsules , L-Carnitine L-Tartrate - 90 Capsules , Biozyme Shred - 90 Capsules , Bottle Pro, 2 L , Cyclone Shaker, 700 Ml , Stainless Steel Shaker, 750 Ml , Insulated Steel Bottle, 1 L , Mens Multivitamin – 30 Tablets , Mens Multivitamin – 60 Tablets , Womens Multivitamin – 30 Tablets , Womens Multivitamin – 60 Tablets , Essential Multivitamin – 30 Tablets , Odourless Wild Fish Oil 1500Mg – 40 Capsules , Odourless Wild Fish Oil 1500Mg – 60 Capsules , Odourless Wild Fish Oil 1500Mg – 90 Capsules , Odourless Wild Fish Oil 1500Mg – 200 Capsules , Odourless 4X Strength Wild Fish Oil 1800Mg – 60 Capsules , Odourless Wild Fish Oil 1000Mg – 150 Soft Capsules , Odourless Wild Fish Oil 1000Mg – 200 Soft Capsules , Clinical Strength Deep Sea Krill Oil – 30 Capsules , Collagen+ Hyaluronic Acid – 30 Tablets , Collagen Glow Powder – 90G Oral Powder , Vegan Collagen Builder – 30 Tablets , Biotin+ – 30 Tablets , Biotin+ – 60 Tablets , Glutathione+ – 30 Soft Capsules , High Strength Cranberry – 30 Capsules , Iron – 30 Tablets , Mens Endurance Boost – 30 Tablets , Magnesium – 60 Tablets , High Strength Magnesium Glycinate & Citrate – 90G Oral Powder , Magnesium, Calcium + D3 – 60 Tablets , Vitamin D – 90 Tablets , Vegan Calcium + Vitamin D – 60 Tablets , Calcium + Vitamin D – 90 Tablets , Heart Health – 30 Soft Capsules , Co Enzyme Q10 – 50 Capsules , Joint Repair – 60 Tablets , Glucosamine Sulfate+ – 60 Tablets , Liver Detox – 30 Tablets , Liver Detox – 60 Tablets , High Strength Milk Thistle – 30 Tablets , Lutein & Zeaxanthin Eye Health+ – 30 Tablets , Metabolism+ – 60 Tablets , Immunity Booster+ – 30 Tablets , Probiotic+ Prebiotic Gummies – 30 Gummies , Plant Protein – 500G , Ultra Omega-3 (Epa 525Mg & Dha 400Mg) – 30 Tablets , Ultra Omega-3 (Epa 525Mg & Dha 400Mg) – 90 Tablets , Advanced Multivitamin For Sports, Unflavoured – 30 Tablets , Advanced Multivitamin For Sports, Unflavoured – 90 Tablets , Shilajit With 80+ Trace Minerals – 10G , Shilajit With 80+ Trace Minerals – 20G , T Boost, Unflavoured – 60 Tablets , T Boost, Unflavoured – 120 Tablets , Multivit Men, Unflavoured – 30 Tablets , Multivit Men, Unflavoured – 90 Tablets , Advanced Multivitamin For Women, Unflavoured – 30 Tablets , Advanced Multivitamin For Women, Unflavoured – 90 Tablets , Liver Detox With Silybin Milk Thistle Extract – 75 Tablets , Glutathione + Nutroxsun, Unflavoured – 30 Tablets , Joint Ease With 1500Mg Of Glucosamine & 1200Mg Of Chondroitin – 90 Tablets , Vegan Omega 3 6 9 – 90 Softgels , Advance Calcium Vitamin D3 & K2mk7, Unflavoured – 90 Tablets , Ashwagandha With 600 Mg Of Ksm-66 – 60 Capsule , Aceclofenac (100Mg) + Paracetamol (325Mg) – Strip Of 15 Tablets , Aceclofenac (100Mg) + Paracetamol (325Mg) + Serratiopeptidase (10Mg) – Strip Of 10 Tablets , Amoxycillin – Strip Of 10 Tablets , Azithromycin – Strip Of 5 Tablets , Olopatadine 0.2% – Eye Drop 5Ml , Ivermectin (6Mg) + Albendazole (400Mg) – Strip Of 1 Tablets , Cefexime – Strip Of 10 Tablets , Cetirizine (5Mg) + Paracetamol (325Mg) + Phenylephrine (10Mg) – Strip Of 10 Tablets , Chloramphenicol – Strip Of 10 Capsule , Trypsin Chymotrypsin (100000Au) – Strip Of 20 Tablet , Chlorzoxazone (500Mg) + Diclofenac (50Mg) + Paracetamol (325Mg) – Strip Of 10 Tablet , Cholecalciferol-60000Iu – Strip Of 4 Capsule , Ondansetron (4Mg) – Strip Of 10 Tablet , Elemental Iron (100 Mg) + Folic Acid (1.5 Mg) – Strip Of 10 Tablet , Camphor-25Mg + Chlorothymol-5Mg + Eucalyptol-125Mg + Menthol-55Mg + Terpineol-120Mg – Strip Of 15 Capsule , Levocetirizine (5Mg) + Montelukast (10Mg) – Strip Of 15 Tablets , Levocetirizine (5Mg) – Strip Of 10 Tablet , Levocetirizine (10Mg) – Strip Of 10 Tablet , Ammonium Chloride-138Mg + Diphenhydramine-14.08Mg + Sodium Citrate-57.03Mg – Syrup 100Ml , Alpha Lipoic Acid-100Mg + Folic Acid-1.5Mg + Mecobalamin-1500Mcg + Pyridoxine Hydrochloride-3Mg – Strip Of 10 Capsule , Metronidazole – Strip Of 10 Tablet , Cholecalciferol-1000Iu + Magnesium-250Mg – Strip Of 10 Tablet , Moxifloxacin-0.5%W/V – Eye Drop 5Ml , Loteprednol Etabonate (0.5% W/V) + Moxifloxacin (0.5% W/V) – Eye Drop 5Ml , Calcium Pantothenate (50 Mg) + Cyanocobalamin (15 Mcg) + Nicotinamide (45 Mg) + Riboflavine (10 Mg) + Thiamine Mononitrate (10 Mg) + Vitamin B6 / Pyridoxine (3 Mg) – Strip Of 30 Tablets , Ofloxacin (200Mg) + Ornidazole (500Mg) – Strip Of 10 Tablet , Pantoprazole – Strip Of 15 Tablets , Paracetamol – Strip Of 10 Tablet , Piroxicam (20Mg) – Strip Of 10 Tablet , Carboxymethylcellulose-0.5%W/V – Eye Drop 10Ml , Diclofenac (50Mg) – Strip Of 10 Tablet , Diclofenac (50Mg) + Paracetamol (325Mg) – Strip Of 10 Tablet , Dicyclomine (20Mg) + Paracetamol (325Mg) – Strip Of 10 Tablet , Vitamin D3 / Cholecalciferol(60000.0 Iu) – Strip Of 12 Capsule Total In Figures 0.0 0.0 Inr Zero Only 4.0 Construction Of Chamber For 100Mm Sluice Plates Item5 10.0 Nos Quoted Rate In Figures Select % 0.0 0.0 Zero Only Quoted Rate In Words Inr Zero Only
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 1
Madhya Pradesh View Result →
13.
Educational and Research Institute #10575911 Price Bid
Supply Of Coronary Engiography Kit And Its Related Consumables , Group A: Coronary Angiography ( Items Used In Cath Lab ) , ( A ) Angio Guidewire Hydrophylic 0.035 / 0.023 – J / 0.032 J-Tip 150 Cm - Us Fda And Japan Pmda And Dcgi Approved ( B ) Angio Guidewire Hydrophylic 0.035 / 0.023 – J / 0.032 J-Tip 260 Cm - Us Fda And Japan Pmda And Dcgi Approved , Angio Guidewire 0.035 – J / 0.032 J-Tip 150 Cm Translumina Or Equivalent , Angio. Cath. Al1 / Al2 / Al3 – 5F, 6F , Angio. Cath. Ar1 / Ar2 / Ar3 – 5F, 6F , Angio. Cath. Jl -3.0 / 3.5 / 4.0 / 4.5 / 5.0 ( 5F & 6F ) , Angio. Cath. Jr. 3.0 / 3.5 / 4.0 ( 5F & 6F ) , Angio. Cath. Pigtail 4F / 5F / 6F , Ima - 6F / 7F , Multipurpose6f, 7F , Peadiatric Input Sheath 4F / 5F , ( A ) Radial Sheath 5F / 6F- Us Fda And Japan Pmda And Dcgi Approved ( B ) Femoral Sheath 5F / 6F-U Us Fda And Japan Pmda And Dcgi Approved , Two Locking Mechanism ( A ) Snap On / Click Off ( B ) Rotating Type. Have Unique Intro Cross Cut Valve Which Maintain Uncompromised Hemostasis To Avoid Bleeding.Radial Sheath 5F / 6F Or Equivalent , Tiger 5F / 6Fcatheter- Us Fda And Japan Pmda And Dcgi Approved , Tiger 5F / 6F Catheter Equivalent Tig 2 Inner Diameter To 0.050 With Maximum Pressure Upto 1200 Psi. , Angiographic Catheter – Tig Curve Comprised Of A Two-Layer Construction, Double Braided Stainless-Steel Two-Ply Mesh Sandwiched Between Layers Of Polyurethane And Polyamide Elastomers. •Must Have 32 Strands Of Stainless-Steel Braid. •Must Have The Shaft Inner Layer And Outer Layer Contain Barium Sulphate. •Must Have Anti-Kinking Protector Sleeve, With Non-Braided Tip Shaft ( Distal -2 Cm ) . •Trans Radial Catheter Must Have Shapes Designed To Cannulate Left And Right Coronary Arteries Tig, Tig Ii, Jacky, Sarah. •Must Be Available In 4F, 5F, 6F Sizes •Must Have Inner Diameter Of 4F = 1.03Mm, 5F= 1.20Mm, 6F = 1.30Mm •Usfda And Pmda –Approved , Dye ( Non-Ionic Contrast Agent 100Ml It Should Be Us Fda / Ce & Dcgi Approvediohexol As Salt Name With 350 Mg / Ml Concentration , Iodixanol As A Salt Name 320Mg / Ml With Plastic Bottle With Hanger 100Ml Pack , ( A ) Femoral Sheath 5F / 6F / 7F / 8F / 9F / 10F / 11F / ( B ) Femoral Long Sheath 30 To 50 Cm , Unilock Syringe 10 Ml , Iv Cannula ( 18, 20, 22 G ) , Disposable Ecg Electrodes For Adults- Us Fda / Ce & Dcgi Approved • Adult Diaphoretic Foam Electrodes. • Should Be Pre-Gelled, Peel And Stick Electrode With Excellent Adhesion • Should Have No Residue Once Removed Should Conform To Or Exceed The Highest Industrial Standard For Ecg Electrodes, Quality Certification From Authorized Agencies To Be Provided , Cd – R Media With Atleast 700 Mb Storage And Atleast 52X Recordable Speed Dvd , Pressure Monitoring Line 200Cm , Manifold ( Two Port ) ( Right On ) , High Pressure Line - 200 Cm , Dvd , Docking Wire , Swan Ganz Catheter - Ce Approved - 6F / 7F Us Fda / Ce And Dcgi Approved , Gadoteric Acid 10 Mlvial With Usfda Approved , Gadotericacid20 Ml Vials With Usfda Approved , Radial Artery Haemostasis Device- ( T.R. Band ) Consists Of Two Balloon Specially Designed For Spot Compression Of The Radial Puncture Site. Must Have Belt Magic Tape For Fast Application •Must Have Curved Support Plate. Must Have Green Positioning Marker. •Must Be Available In 2 Sizes – 24Cm And 29Cm Usfda+Pmda Approved• , Special Slender Sheath ( Gss ) Must Have Unique Thin Wall Technology Reducing The Outer Diameter By 1• Fr Size Whilst Maintaining The One Size Lager Inner Diameter. Must Have 7Fr Sheath With Outer Diameter Of 2.8Mm, 6Fr With Od Of• 2.46 Mm & 5Fr With Od Of 2.13Mm. Hydrophilic M Coating With 20 / 21G Surflash Needle And Tif Tip• Technology Which Provide Optimal Tapering Design. Usfda / Pmda Approved• , Group B: ( Consumable For Ptca ) , ( A ) Judkins Guiding Catheter ( Jr Jl & Pigtail Ebu, Routine And Sidehole Catheterxb, Xbr ( Terumo, Cordis, Meditronic, Boston Scientific, Translumina ) Or Equivalent Qualityus Fda / Ce & Dcgi Approved • 4 French / 5 French / 6 French / 7 French / 8French Size Left And Right Judkins Catheters In Various Standard Curves And Lengths. , Special Guiding Catheter – Ikari Curve •Must Have Ikari Curve For Radial Route. •Must Have Stainless Steel Flat Wire Braid •High Strength Wired Braided Catheter With Inner Layer Of Ptfe With Fluoropolymer. •Must Have Zone Technology - Five Zone Each Fabricated From A Material Of Different Stiffness. •Must Have Larger Lumen.6Fr Id - .071 •Usfda / Pmda Approved , Ptca Inflation Device – Us Fda Approved , Nih Catheter Us Fda / Ce & Dcgi Approved • 4 French / 5 French / 6 French / 7 French / 8French In Various Standard Curves And Lengths. , Cournard Guidingcatheter Us Fda / Ce & Dcgi Approved • 4 French / 5 French / 6 French / 7 French / 8French In Various Standard Curves And Lengths. , Double Lumen Thrombo-Aspiration Catheter , ·Swan Ganz Catheter , Vascular Closure Device With Bio Absorbable Pga Suture That Provide A Secure Seal, , Bioabsorbable Collagen Designed To Conform To The Arteriotomy For Confident Closure, And Low Profile Bioabsorbable Anchor ( 50:50 Blend Glycolideandlactidepolyer ) To Fit Closely Against Arterial Wall Leaving Blood Flow Undistributed While Maintaining Vessel Diameter. Againt . , Ptca Inflation Device- Us Fda / Ce & Dcgi Approved • Efficient Locking System To Maintain High Pressure • Rapid Inflation And Deflation • Clear Barrel For Easy Visualization Of De-Bubbling • Luminescent Analog Pressure Gauge ( Up To 30 Atm ) • Ergomatric And Use Friendly Hand Held Design. , ( A ) ( Haemostatic Y-Connector ) For Ptca – Push Mechanism - Us Fda / Ce & Dcgi Approved • Should Accommodate Virtually All Interventional Devices • Luer Connector At The Guiding Catheter End • Rotating Adapter At The Guiding Catheter End • Should Have Bleed Back Safety Mechanism • Stepwise Control For Open, Semi-Open And Closed Position ( B ) Ptca Y Connector 400 Kpa Leak-Proof Seal From Proprietary Designed Valve, *7F-9F Compatible Lumen Allowing Delivery Of Wide Range Of Devices And Torque And Introducer Fit 0.014-0.021 Guide Wire. , Hydrophilic Guidewire With Mcoat Technology Tapered Tip, Single Nitinol Core Alloy, Tungsten-Infused Polyurethane Jacket • Hydrophilic Polymer Coat. •One Piece Construction & Radiopaque Polyurethane Jacket. •Must Be Available In Standard And Stiff. •Must Be Available In .035, .032, .038, .025, .018 Diameter And 260 Cm Length - Straight / Angled / 1.5 Mm J Shape •Usfda And Pmda Approved , ( A ) Baby J Wire With 1.5Mm J Tip – 180 Cm And •Baby J Curve Must Have Radius Of 1.5 Mm. •Super Elastic Nitinol Alloy, M Coat Hydrophilic Coat, •One Piece Construction For 1:1 Torque & Radiopaque Polyurethane Jacket. •Must Have Tungsten-Infused Polyurethane Jacket. •Usfda And Pmda Approved ( B ) Baby J Wire With 1.5Mm J Tip – 260 Cm And •Baby J Curve Must Have Radius Of 1.5 Mm. •Super Elastic Nitinol Alloy, M Coat Hydrophilic Coat, •One Piece Construction For 1:1 Torque & Radiopaque Polyurethane Jacket. •Must Have Tungsten-Infused Polyurethane Jacket. •Usfda And Pmda Approved , .014” One Piece Core Workhorse Wire With Jointless Spring Coil With Sion Technology Having Composit Core With Actone Inside Length 28Cm Tip Load 0.7 Gm 180 Cm Length Tip Radiopacity 3 Cm , .014” One Piece Core Workhorse Wire With Jointless Spring Coil With Sion Technology Having Composit Core With Actone Inside Length 20Cm Tip Load 0.5 Gm 180 Cm Length Tip Radiopacity 3 Cm , .014” On E Piece Core Workhorse Wire With Jointless Spring Coil With Sion Technology Having Composit Core With Actone Inside Length 22Cm Polymer Sleee Length With Slip Coat Coating Over The Polymer Sleeve Tip Load 0.8 Gm 180 Cm Length Tip Radiopacity 3 Cm , .014” On E Piece Core Workhorse Wire With Jointless Spring Coil 22 Cm Polymer Sleev Length With Slip Coat Coating Over The Polymer Sleeve Tip Load 1Gm 180 Cm Length Tip Radiopacity 3 Cm , Extra Support 0.014Wire; 0.7 Gf Tip Load Tip Radio Opacity 4 Cm 180 Cm Length Ptfe Coating Over The Shaft Silicone Coating Ovr Spring Coil , .014 One Piece Core Workhorse Wire With Jointless Spring Coil With Polymer Jacket With Sion Technology Having Comosit Core With Actone Inside Length 28 Cm With Tip Load 0.8 Gm 180 Cm Length Tip Radiopacity 3 Cm , .014 One Piece Core Workhorse Wire With Jointless Spring Coil With Polymer Jacket With Sion Technology Having Comosit Core With Actone Inside Length Tip Radiopacity 3 Cmwith Tip Load 0.5 Gm , .014 One Piece Core Workhorse Wire With Jointless Spring Coil With Tapering To .009” 0.8Gf Of Tip Load; 16 Cm Plymer Sleeve Length With Slip Coat Coating Over The Polymer Sleeve, 190 Cm Length Tip Radiopacity 16 Cm , .014 One Piece Core Cto Wire With Jointless Spring Coil Ptfe Coating Over The Shaft, Tip Load 3G, Tip Load 3G, 4.6 G And 12G, 180 Cm Length With Tip Radiopacity 11 Cm , One Piece Core Wire With Jointless Spring Coil With Slip Coat Coating Over The Spring Coil Tapering To .009” Tip Load 9G 180 Cm Length Tip Radiopacity 20 Cm , One Piece Core Wire With Jointless Spring Coil With Slip Coat Coating Over The Spring Coil Tapering To .009” Tip Load 12G 180 Cm Length Tip Radiopacity 20 Cm , One Piece Core Wire With Jointless Spring Coil With Slip Coat Coating Over The Spring Coil Tapering To .008” Tip Load 20G 180 Cm Length Tip Radiopacity 17 Cm , .010” One Piece Core Wire With Joint Less Spring Coil Length 15 Cm Cone Tip With A Tip Load Of 3.5 Gm 190 Cm Length Tip Radiopacity 15 Cm , Ptca Guide Wire – Core Material Elastinite Nitinol For Excellent Flexibility And Durability, Shaping Ribbon For Excellent Shape Retention And Atraumatic Tip Load Less Than 0.65 Gm With Regular Length, Regular Shaft Support And Floppy Tipus Fda / Ce & Dcgi Approved , Ptca Guide Wire-Durasteel Stainless Steel For Durability And Excellent Torque Control, Full Polymer Jacket, Core To Tip Design For Precise Steering And Tip Control, Various Tip Loads 0.8 Gm To 1.2 Gm For Complex Anatomies, Hydrophilic Coating For Longer Lasting Lubricity. Us Fda / Ce & Dcgi Approved , Ptca Guide Wire – Exchange Length Us Fda / Ce & Dcgi Approve , Ptca Guide Wire-Durasteel Stainless Steel For Durability And Excellent Torque Control, Full Polymer Jacket, Core To Tip Design For Precise Steering And Tip Control, Various Tip Loads 1.5 Gm To 4.1.Gm For Complex Anatomies, Hydrophilic Coating For Longer Lasting Lubricity. Us Fda / Ce & Dcgi Approved , Ptca Guide Wire – Hydrophilic Coated, Exchange Length Us Fda / Ce & Dcgi Approved , Ns Ptca Wire Floppy. Extra Floppy Intermediate & Hypercoat Including Cto Wires .014Diameter Ptca Wires With Directly Jointed Sus And Nitinol Shaft Through Duocore Technology For Superior Torque Transmission Available In Various Tip Loads- Us Fda And Japan Pmda And Dcgi Approved , Extra Floppy Ptca Guide Wire – 2 Mm Silicon Coated Distal Tip, 0.014” Diameter And 180 / 300 Cm Length •Must Have Platinum Coil At Distal Tip. Balance Of Hydrophilic And Hydrophobic Coating •Must Have Directly Jointed Sus And Nitinol Shaft Through Duocoretechnology And Silicon Coated Joint. •Must Have Ptfe Coating From 25 To 180 Cm Length. & Mucus Coat Hydrophilic Coating Up To 248 Mm •Should Have 0.6-Gram Force Tip Loads •Usfda+Pmda , Floppy Tip Ptca Guide Wire – 2 Mm Silicon Coated Distal Tip, 0.014” Diameter And 180 Cm Length. •Must Have Platinum Coil At Distal Tip. Balance Of Hydrophilic And Hydrophobic Coating •Must Have Directly Jointed Sus And Nitinol Shaft Through Duocoretechnology And Silicon Coated Joint. •Must Have M Coat Hydrophilic Coating Up To 248 Mm, & Ptfe Coating From 25 To 180 Cm Length. •Should Have 1 Gram Force Tip Loads •Usfda+Pmda , Hypercoat Ptca Guide Wire With 9.7-Gram Force Rail Support– Mucus Coated Hydrophilic Distal Tip, 0.014” Diameter And 180 / 300 Cm Length •Must Have Platinum Coil At Distal Tip. 14 Mm Tip Shape Length. •Must Have Directly Jointed Sus And Nitinol Shaft Through Duocoretechnology And Silicon Coated Joint. •Must Have M Coat Hydrophilic Coating Up To 250 Mm & Ptfe Coating From 25 To 180 Cm Length. •Should Have 1-Gram Fore Tip Load •Usfda+Pmda , Cto Stiff Ptca Guide Wire - 3.6-Gram Force Tip Load – 2 Mm Silicon Coated Distal Tip, 0.014” Diameter And 180 Cm Length. •Must Have Platinum Coil At Distal Tip. Balance Of Hydrophilic And Hydrophobic Coating •Must Have Directly Jointed Sus And Nitinol Shaft Through Duocoretechnology And Silicon Coated Joint. •Must Have M Coat Hydrophilic Coating Up To 248 Mm & Ptfe Coating From 25 To 180 Cm Length. •Should Have 3.6-Gram Fore Tip Load •Usfda+Pmda , Micro Catheter To Be Used For Cto Fine Cross Antegrade And Retrograde Apporch. -Us Fda / Ce & Dcgi Approved , Aspiration Thrombectomy Catheter • Available In Size 6F, 7F Both, Must Have Entry Profile 0.019 Inches • Must Have 1.30 Mm Square Suction Area • Braided Polyamide Elastomer Shaft, Stainless Steel Wire Braiding And Guide Wire Type Stylet, • 6.0Mm Tip Length For Making Aspiration Inlet To Come Closer To The Target Thrombus And 10Cm-Length Depth. • Must Have Distal 40 Cm Hydrophilic Coating. • Pmda And Dcgi Approved , Cto Indicatedsemi-Complaint Balloon With Slim Seal Technology On Distal Tip With Lesion Entry Profile Of 0.017, Crossing Profile Of 0.021 And Single Flexible Tungsten Marker Available In Unique Diameter Of 1.2Mm With Variety Of Lengthsus Fda / Ce & Dcgi Approved , Ptca Balloon ( Non-Compliant ) -Us Fda / Ce & Dcgi Approved • Quote Both Monorail ( Rapid Exchange ) And Otw Balloons • Available In All Sizes From 2 - 4.0 Mm, Variable Lengths Should Have A Very High Rated Burst Pressure , Ptca Balloon Ultra Lowentry Profile Balloon With 0.016 Entry Profile, Thin Marker Of 25Micro Milimeter And Core Wire Shaft For Batter Pushabilty With Widerange From 1Mm To 4Mm Diameter. , Ptca Balloon Semi Compliant Cto Balloon With Ultra Low Entry Profile With 0.40Mm Or 0.016 And Entry Profile From 1.25*10 To 2.25*10 Remains Same For Crossablity Even With Higher Diameter Balloon. , Ptca Balloon Semi Compliant Balloon With Entry Profile Of0.40Mm Or 0.016 Or Execellentcrossablity ( A ) Sirolimus Drug Eluting Balloon With Nano Carriers Ce Marked ( B ) Drug Coated Balloon - Drug Coated Balloon With 2 ?G / Mm2 Dose Of Paclitaxel With Polysorbate& Sorbitol As Carrier Which Will Deliver An Optimal, Therapeutic Drug Dose To The Target Vessel Wall After A Minimum 30 Second Inflation Time. Available In Sizes- 035 Guidewire Compatible – 120 Cm Shaft - 4Mm -6Mm Dia, Lengthupto 150Mm, 035 Guidewire Compatible – 75Cm Shaft – 5Mm – 12 Mm Dia, Length 60Mm, 014 Guidewire Compatible – 150 Cm Shaft – 2Mm To 3.5Mm Dia, Length 120 Mm , High Pressure Ptca Dilatation Catheter With Small Entry Profile Of 0.43Mm And Small Balloon Profile Of 0.034” With Special Silicon Coating On Balloon To Avoid Mellon Seed Effect. • Small Distal Shaft Profile Of 2.5-2.6Mm To Allow Kbt In 6Fr Large Lumen Guiding Catheter. , Lesion Entry Profile - 0.016 / Nominal Pressure - 12 Bars / Rbp - 22 Bars / Impeccable Tip / Hydrophilic Coated / Non-Compliant Balloon / Prime Shaft , Dual Layer / Rbp 35 Bars / Abp 45 Bars / Strictly Non-Compliant , Ptca Balloon ( Semi Compliant ) – ( Usfda Approved ) Monorail, Bi Segment Inner Lumen Shaft, Monorail Catheter, Z Glide Coating, Proximal Shaft – 2.6Fr, Distal Shaft – 2.3 Fr, Balloon Material Opti Leap, Delivery System Working Length 143 Cm Size 1.2, 1.5, 1.2 Push, 1.5 Push, 2-4Mm Dia X 8, 12, 15, 20, 30 Lengths , ( A ) Ptca Balloon ( Non Compliant ) – ( Usfda Approved ) Bi Segment Inner Lumen Shaft, Monorail Catheter, Z Glide Coating, Proximal Shaft – 2.6Fr, Distal Shaft – 2.3 Fr, Balloon Material Opti Leap, Delivery System Working Length 143 Cm Size - 2-6Mm Dia X 6, 8, 12, 15, 20, 30 Lengths ( A ) High Pressure Non-Compliant Balloon With Innovative Triple Layer Balloon Technology With High Pressure Resistance Of 22 Atm. Must Have Elastomer Outer Layer, Middle Layer Of Polyamide And Inner • Most Layer Of Elastomer. Must Have Nominal Pressure Of 12Atm And Rbp Of 22Atm. •Shorter Thin Distal Tip Of 2.9Mm With Low Entry Profile Of 0.43 Mm. Must Have Hydrophilic Mucus Coating Must Have 3.0 Mm Short Taper Balloon Shoulder& Must Have 0.8Mm Shorter And 25?M Thinner Radiopaque Marker For Lower Crossing Profile.Must Have 2.6 French Stainless Steel Core Wire Structured Shaft•& Stainlesssteel Stylet In Mid Shaft. Must Have Hypotube Without Ptfe Coating. Must Have Three Pleats Re-Wrappable Structure. Pmda+Ce Approved• , Cto Balloon With Ultra – Ultra Low Entry Profile Of 0.016 Must Have Hydrophilic Mucus Coating. •Should Have Smallest Diameter 1.00Mm And 5Mm Length. •Must Have 0.8Mm Shorter And 25?M Thinner Radiopaque Marker For Lower Crossing Profile. •Must Have Flexible Tip With Short Balloon Bonding Part Of 0.4Mm. •Nominal Pressure Of 06 Atm And Rbp Of 14 Atm •Must Have 2.4 To 2.7 French Tapered Stainless Steel Core Wire Structured Shaft. •Must Have Three Pleats Re-Wrappable Structure. •Pmda+Ce Approved , Dual Layer / Rbp 35 Bars / Strictly Non-Compliant ( Only 10% Growth ) / Andfor Super High Pressure Ptca, A Manometer Of 55 Atm , Cto Nc Balloon Diameter 0.85 Mm Entry Profile .016 Rbp 21 Hydrophilic Single Proximal Marker. , Dedicated Dual Lumen Micro Catheter For Side Branch Access , Thrombus Aspiration Catheter With Removable Core Wire And 30Cm Hydrophilic Coating From The Tip; Available In 6F And 7F , Semi-Complaint Ptca Balloon With Smallest Entry Profile Of 0.0157, Tapered Balloon Shape, Unique Tri-Fold Wrapping Technology, Tr2 Hydrophilic Coating; Available In Lowest Profile 1 Mm Diameter, Longer Shaft Length Of 146Cm. , Non-Compliant Ptca Balloon With Highest Rbp Up To 22 Atm; Tapered Balloon Tip To 4Mm With Lowest Shoulder Angle To 32 Deg; Available In Lowest Profile 1.5Mm Diameter, Longer Shaft Length Of 146Cm. , Special Ptca Balloon ( Non-Compliant ) For Post Dilation. Must Have Diameter Starting From 1.75 Mm-5.0 Mm. Balloon Material Must Be Nylon For Controlled Compliance. Quote Both Monorail ( Rapid Exchange ) Balloon. Ce Approved , Cutting Balloon For Ptca Having Microsurgical Atherotomes ( Blades ) - Us Fda / Ce & Dcgi Approved • Monorail ( Rapid Exchange ) And Over-The-Wire ( Otw ) Balloons Available In The Sizes And Lengths , Wire Based Scoring Balloon Cathethr. Us Fda / Ce & Dcgi Approved • Available In The Sizes And Lengths Monorail ( Rapid Exchange ) , Everolimus Eluting Stent. Cobalt Chromium With 60 Microns Strut Thickness. Hydrophilic Coating On 3 Mm Balloon Shaft. Biodegradable Coating Only On Abluminal Side. , Sirolimus Eluting Stent. Cobalt Chromium With 60 Microns Strut Thickness. Hydrophilic Coating On 3 Mm Balloon Shaft. Biodegradable Coating Only On Abluminal Side. , High Pressure Semi Complaint Ptca Balloon Must Have Low Entry Tip Profile Equal To Or Less Than 0.016 Should Have Nominal Pressure 6 Atm Or Above And Rbp Above 14 Atmmust Be Available In Diameter 1.0 Mm Along With Other Size Matrix Starts From Diameter 1.75 Mm To 4 Mm Quote Both Monorail And Otw Balloonus Fda / Ce & Dcgi Approved , Special Ptca Balloon ( Non Complaint ) For Post Dilations Must Have Diameter Strating From 1.75 Mm To 5.0 Mm Balloon Material Must Be Nylon For Controlled Compliance. Quote Both Monorail And Otw Balloonus Fda / Ce & Dcgi Approved , Semi Complaint Balloon - Thin Multi-Layer Balloon, Tri Fold Balloon Design For Good Rewrap, Semi-Complaint Coronary Balloon With Laser Bond Technology On Distal Tip With Crossing Profile Of 0.021”, Tip Entry Profile Of 0.017”, Nominal Pressure Of 8Atm And Rbp Of 14Atm Available In Diameter 1.20-4.00Mm And Lengths 6Mm -30Mmus Fda / Ce & Dcgi Approved , Non-Complaint Coronary Balloon With Tri-Fold Layers And Tip Entry Profile Of 0.018” With Nominal Pressure Of 12Atm And Rbp Of 18Atm. Excellent Flexibility And Tight Rewrap With Flat Compliance For Excellent Stent Apposition, Available In Diameter 2.0-4.5Mm And Lengths In 8Mm-25Mmus Fda / Ce & Dcgi Approved , Workhorse Guidewire With Triple Spring 304V Stainless Steel With Niti Distal Core And Cold Working Rotary Swagging Tip Available In Tiploads Between 0.6-0.8Gm And Lengths ( 190 / 300Cm ) Us Fda / Ce & Dcgi Approved , Semi-Complaint Coronary Balloon With Slim Seal Technology On Distal Tip With Crossing Profile Of 0.021”, Lesion Entry Profile Of 0.017” And Microglide Coating Available In Diameter 2.25-5.00Mm And Lengths 6-30Mmus Fda / Ce & Dcgi Approved , Special Ptca Balloon Non-Complaint Coronary Balloon With Multilayer Crossflex Balloon Technology And Round Tip With Lesion Entry Profile Of 0.018” Available In Diameter 1.5Mm-5Mm And Lengths In 6Mm-25Mm With Skive Technology On Mid Shaft Of Dilatation Catheterus Fda / Ce & Dcgi Approved , Workhorse Guidewire With Durasteel Core, Responsease Core Grind Technology With Hydrophilic Coating And 1Cm Uncoated Distal Tip For Tactile Feedback Available In Multiple Variants With Same Tipload Of 0.9Gmus Fda / Ce & Dcgi Approved , Workhorse Guidewire With Triple Spring 304V Stainless Steel With Niti Distal Core And Cold Working Rotary Swagging Tip Available In Tiploads Between 0.6-0.8Gm And Lengths ( 190 / 300Cm ) .Us Fda / Ce & Dcgi Approved , Cto Indicated Penetration Guide Wire For Antegrade Wire Escalation ( Awe ) Technique With Unique Micro Textured Tip For Cap Engagement And Tapered Tip For High Penetration Powers. Tip Load 11 To 14 Gm Penetration Power – Above 160 Kg / In2us Fda / Ce & Dcgi Approved , Tuohy Borst ( Haemostatic Y-Connector ) For Ptca Push Pull Mechanism – Us Fda , Amplatz Wire – Ptee Coated – ( Regular Length ) .035 Large Stainless Steel ( Ss ) Core With Ss Flat Wire Coils Gradual Taper With Core To Tip Support And Flexibility For Atraumatic Navigation Through Fortuous Anatomy 150 Cm And 180 Cm Usfda Approved , Group C: Stents , Stainless Steel Coronary Stents, Premounted On Balloon – Us Fda / Ce & Dcgi Approved • Monorail ( Rapid Exchange ) And Over-The-Wire ( Otw ) • Available In The Sizes And Lengths , Stainless Steel Coronary Stents, Premounted On Balloon –Us Fda / Ce & Dcgi Approved • Monorail ( Rapid Exchange ) And Over-The-Wire ( Otw ) • Available In The Sizes And Lengths , Cobalt Chromium Coronary Stents, Premounted On Balloon – Us Fda / Ce & Dcgi Approved • Monorail ( Rapid Exchange ) And Over-The-Wire ( Otw ) • Available In The Sizes And Lengths , Cobalt Chromium Coronary Stents, Premounted On Balloon – Us Fda / Ce & Dcgi Approved • Monorail ( Rapid Exchange ) And Over-The-Wire ( Otw ) • Available In The Sizes And Lengths , Covered Coronary Stents – Us Fda / Ce & Dcgi Approved • Monorail ( Rapid Exchange ) And Over-The-Wire ( Otw ) Both • Available In The Sizes And Lengths • Covered Graft Stent For Dissectedartery , Stainless Steel Renal Stents, Premounted On Balloon – Us Fda / Ce & Dcgi Approved • Monorail ( Rapid Exchange ) And Over-The-Wire ( Otw ) • Available In The Sizes And Lengths , Zotarolimus Eluting Stent - Us Fda / Ce & Dcgi Approved , Abluminally Coated Sirolimus Eluting Thin Struts Microporus Chromium Cobalt Stent With Bio Absorbable-Polymer Matrix, Where Balloon Is Also Coated With Sirolimusus Fda / Ce & Dcgi Approved , Abluminally Coated Sirolimus Eluting Thin Struts Microporus Stain Less Steel Stent With Bio Absorbable-Polymer Matrix, Where Balloon Is Also Coated With Sirolimusus Fda / Ce & Dcgi Approved , Sirolimus Eluting Stent Cobalt Chromium With Diameter Of 2Mm To 4.5Mm With Length Of 8Mm To 48Mm With Biogradable Polymer.Us Fda / Ce & Dcgi Approved , Biolimus Eluting Stent - Us Fda / Ce & Dcgi Approved , Tacrolimus Eluting Stent - Us Fda / Ce & Dcgi Approved , Drug Eluting Biodegradable Polymer & Shellac Resign Top Coatus Fda / Ce & Dcgi Approved , Everolimus Eluting Chromium Cobalt Multi Link Drug Eluting Stent -Us Fda / Ce & Dcgi Approved , Everolimus Eluting Chromium Cobalt Multi Link 48Mm Drug Eluting Stent -Us Fda / Ce & Dcgi Approved , Everolimus Eluting Platinum Chromium Stent Bio Absorvbale Polymer Stentus Fda / Ce & Dcgi Approved , Sirolimus Eluting Stent Cobalt Chromiumwith 2 Links & 8 Crownswith Diameter Of 2Mm To 4.5Mm With Length Of 8Mm To 38Mm With Biogradable Polymer And Gradient Coating.Us Fda / Ce & Dcgi Approved , Biodegradable Polymer / Microporous Surface / Sirolimus Drug & Shellac Resign / Abluminal Coating / Temperature Control Device-Tag Alertus Fda / Ce & Dcgi Approved , Dual Drug Polymer Free Stent / Plat Form-Cobalt Cromium / Probucol Drug Instead Of Polymer / Microporous Surface / Abluminal Coating / Shellac Resin / Strut Thickness 79Micron , Sirolimus Coated Drug Stent On Cobalt Chromium - Ce / Us Fda And Dcgi Approved , Silicon Carbide And Sirolimus Drug Eluting Stent – Ce / Us Fda And Dcgi Approved , C.P. Stent Covered , C.P. Stent Uncovered , Drug Eluting Platinum Chromium Coronary Stents, Premounted On Balloon – Us Fda / Ce & Dcgi Approved • Monorail ( Rapid Exchange ) And Over-The-Wire ( Otw ) Available In The Sizes And Lengths , Sirolimus Eluting Cobalt-Chromium Stent With Abluminal Gradient Coating - ( L-605 Co-Cr Alloy ) ( Should Not Have Drug & Polymer Coating On Joints & Bends ) . 2 Links – 8 Crown Design •Bioresorbable Polymer Of Plcl ( Poly Lactic Acid + Poly Capro Lactone Pcl ) With Degradation Time Of 3-4 Months. Should Have Bioinspired Open Cell In Phase Design. •Low Concentration Of Sirolimus ( 0.8Ug / Mmsq ) . •Minimum Tip Entry Profile Of 0.42Mm •Pmda+Ce Approved , Sirolimus Eluting Cobalt-Chromium Stent With Abluminal Gradient Coating - ( L-605 Co-Cr Alloy ) ( Should Not Have Drug & Polymer Coating On Joints & Bends ) . 2 Links – 8 Crown Design •Bioresorbable Polymer Of Plcl ( Poly Lactic Acid + Poly Capro Lactone Pcl ) With Degradation Time Of 3-4 Months. Should Have Bioinspired Open Cell In Phase Design. •Low Concentration Of Sirolimus ( 0.8Ug / Mmsq ) . •Minimum Tip Entry Profile Of 0.42Mm Should Have Gradiant Coating •Pmda+Ce Approved , Polymer Free Evrolimus Eluting Stent Coronary Stent Withco-Cr Platform Havingmicroporous Surface, Abluminal Coating And Shellac Resin Withdiameters Of 2.0 Mm To 4.0 Mm Of Varying Length. Entry Profile 0.016 , Biodegradable Polymer Sirolimus Eluting Coronary Stentwith Stainless- Steel Platform Havingmicroporous Surface, Abluminal Coating And Shellac Resin Withdiameters Of 2.0 Mm To 4.0 Mm Of Varying Length. , Polymer Free Sirolimus Eluting Coronary Stent With Co-Cr Platform Having Microporous Surface, Abluminal Coating And Shellac Resin Withdiameters Of 2.0 Mm To 4.0 Mm Of Varying Length. Entry Profile 0.016 , Biodegradable Polymer Sirolimus Eluting Coronary Stentwith Co-Cr Platform Havingmicroporous Surface, Abluminal Coating And Shellac Resin Withstrut Thickness 68?M ( Sv ) , 79?M ( Mv ) . , Biodegradable Polymer Sirolimus Eluting Coronary Stentwith Stainless- Steel Platform Havingmicroporous Surface, Abluminal Coating And Shellac Resin With Temperature Control Device - Tag Alert , Biodegradable Polymer Sirolimus Eluting Coronary Stentwith Co-Cr Platform Havingmicroporous Surface, Abluminal Coating And Shellac Resin Withs Strut Thickness 68?M ( Sv ) , 79?M ( Mv ) . , New Generation Des Providing Synergywith Biodegradable Polymer With Microporous Surface. Sirolimus Drug And Cobalt Chromium Surface. , Sirolimus Eluting Stent With Biodegradable Polymer. Distal 3 Mm Tip Should Be Hydrophilic Coated. Strut Thickness Should Be 60Microns. , Everolimus Eluting Stent With Biodegradable Polymer. Distal 3 Mm Tip Should Be Hydrophilic Coated. Strut Thickness Should Be 60Microns , Balloon Expandable Pulmonary Artery Stents – Us Fda / Ce & Dcgi Approved • Approved For Pediatric / Adult Use • Available In Various Sizes , Ivc Stents Self Expendable - Us Fda / Ce & Dcgi Approved • Approved For Pediatric / Adult Use • Available In Various Sizes , Everolimus Eluting Chromium Cobalt Multi Link Platform Drug Eluting Stent With True Center Tip For Peak Performance In Complex Leasions -Us Fda / Ce & Dcgi Approved , Sirolimus Bioresorbable Vascular Scaffold Stent Systemus Fda / Ce & Dcgi Approved , Ultrathin Strut 50 Micron Cobalt Chromium Everlimus Eluting Coronary Stents , Group D: Consumable For Peripheral Stenting , Distal Embolic Protection Device - Carotid / Svg • ( One Size For All Carotids ) • Eccentric Filter With Nitinol Loop For360 Degree Wall Apposition • Rx .014 6F Sheath Compatible • 190 Cm Extra Supportwire • Uniform Micro Pore Size Of 110 Micron Pore Size With 1Mm Pore Free Zone • Non-Thrombogenic Nylon Membrane With Hydrophilic Coating • Should Allow Optimal Filtration In Vessels 3– 5.5 Mm Size •Usfda Approved , Balloon Expandable Stent - Renal • Should Be Low Profile, 6F Guide And 0.018 Wire Compatible, Monorail System • Should Have High Consistent Radial Strength, High Flexibility, Enhanced Radiopacity • Should Have Architecture Which Offers Excellent Lumen Coverage And Conformability • Should Have Increased Support And Radial Strength At Proximal End For Ostial Lesion • Stent Should Be Premounted On Semi Compliant Balloon Catheter • Stent Dia 4-7Mm, Length 15 & 19, Cathter Length 90 & 150 Cm. • Should Have Crimping Technology Which Ensures No Stent Slippage From Balloon , Balloon Expandable Stent - Large Diameter • Should Have High Consistent Radial Strength, High Flexibility, Enhanced Radiopacity • Should Have Architecture Which Offers Excellent Lumen Coverage And Conformability • Should Have Low Foreshortening, Low Recoil. • Stent Should Be Premounted On Non Compliant Balloon Catheter To Avoid Dogboning And Proper Scafolding • Should Have Dual Lumen Catheter Design For Faster Deflation • Stent Dia 5-10Mm, Length 27, 37, 57, Cathter Length 135 Cm. • Should Have Crimping Technology Which Ensures No Stent Slippage From Balloon , Self Expanding Stent For Carotid Artery Stenting • Self Expandingelgilloy Stent With Closed Cell Design • Monorail, 0.014 Wire & 6F Sheath Compatible • Reconstrainable Braided Stent • Shaft Length 135Cm • Dia : 6-9 Mm , Peripheral Self Expandable Stent • Should Be Laser Cut Self Expandingnitinol Stent With Proximal And Distal Markers • Should Have Hybrid Cell Design Which Promotes A Balance Of Radial Strength And Flexibility • Stent Struts To Be Electropolished To Avoid Micro Fracture Through Micro Cracks On The Stent Struts • Should Have Controlled Release / Deployment Mechanism To Ensure Precise Placement And Low Foreshortening • Dia 6 - 14 Mm , Length -20, 40, 60 , 80 , 100 , 120 • Should Be 6F Sheath And 0.035 Wire Compatible Across Sent Size Matrix , Peripheral Self Expanding Drug Eluting Stent • Paclitaxel Eluting Self-Expanding Stent With A Polymer That Releases Paclitaxel Over 12 Months With Lowest Dose Density Of 0.167 ?G / Mm2 For Sfa And Ppa. • Triaxial Delivery System • Hybridcell Architecture With Open & Close Celldesisn • Easy Deployment With Thumbwheel & Pull Grip • 6F Sheath Compatibility • Dia - 6 & 7 Mm • Length -40, 60, 80 , 100, 120 Mm • Us Fda Approved • Laser Cut Nitinol Stentdedicatedly Designedfor Sfa & Popliteal • Trixial Delivery System , Hybrid Cell Architecture, • 6F Sheath Compatibility • Dia5, 6, 7 , 8 Mm , Length -40, 60, 80, 100, 120Mm , 150 Mm • Easy Deployment With Thumbwheel & Pull Grip , Inflation Device To Have High Presure Range Upto 26 Atm To Have High Pressure Stopcock Preventing Leakage During High Pressure Inflation 20Cc Volume Holding , Balloons - Nc Workhorse ( 0.035 Wire ) Should Be Non-Compliant / Semi Compliant. Rbp Of 20 - 24 Atm ( 3-8Mm Balloon ) , 14-18 Atm ( 9-12Mm Balloon ) , Should Have High Rated Burst Pressure With Scratch / Puncture Resistant Nybax Material Dual Lumen Shaft With Balloon Laser Bonded And Short Atraumatic Tapered Tip Should Have Lubricious Medi-Glide Coating On Balloon Material Should Have Good Re-Wrap And Low Tip Profile Should Be 5F ( 3-7Mm Balloon ) / 6F ( 8-10Mm Balloon ) / 7F ( 12Mm Balloon ) Sheath And 0.035 Wire Compatible Should Have Min Lesion Entry Profile Of 0.040 ( 1.016Mm ) Should Have Choice Of Long Balloon Lengths 20Mm To 200Mm , Carotid / Renal Angioplasty Balloon • Rx 018 Carotid / Renal Balloon • 018 Guide Wire Compatible • 4F Sheath Compatible To 4 To 7 Mm Diameter With 20Mm Length • Usable Catheter Length 135Cm For All Sizes . • Usfda Approved , Paclitaxel Coated Drug Eluting Balloon For Btk Paclitaxel Coating Should Be 2Ug / Mm2 Should Have Citrus Ester Exipentwith Hydrophobic Coating For Mininising Drug Loss Must Be Compatible With 0.018 -Inch Wire Loading Tool Should Be Avialbale Must Be Compatible With 4 Fr Sheath Balloon Length Should Be 20Mm – 200Mm Dia -2-4 Mm , Paclitaxel Coated Drug Eluting Balloon For Iliac & Sfa Paclitaxel Coating Should Be 2Ug / Mm2 Should Have Citrus Ester Exipentwith Hydrophobic Coating For Mininising Drug Loss Must Be Compatible With 0.018 -Inch Wire Loading Tool Should Be Avialbale Must Be Compatible With 4 Fr Sheath Balloon Length Should Be 20Mm – 200Mm Dia -4-7 Mm , Balloons - 0.018 / 0.014 Wire Compatible Should Be 4F / 5F Sheath And 0.018 / 0.014 Wire Compatible With Choice Of Otw / Monorail Delivery System Should Be Non-Compliant / Semi Compliant Should Have High Rated Burst Pressure With Scratch / Puncture Resistant Pebax Material Should Have Lowest Tip Entry Profile Of Not More Than 0.022 And Good 5 Fold Re-Wrap Design Should Have Bioslide Hydrophilic Coating On Balloon Material Should Have Large Working Range Should Have Excellent Coulum Support With Balloon Laser Bonded And Short Atraumatic Tapered Tip Should Have Full Length Tapered Core Wire For Enhancdpushability And Kink Resistance Should Have Balloon Lengths Starting From 20 Mm- 150 Mm And Balloon Diameter From 3Mm To 10Mm , Balloon - 0.014 Wire Compatible For Btk Procedure With An Ultra-Low Lesion Entry Profile ( 0.017” / 0.43 Mm ) And Best-In-Class Crossing Profile ( 0.030” / 0.76 Mm ) With Deflation Times Of Less Than 10 Seconds*** And Balloon Lengths Up To 220 Mm Balloon Dia From 1.5 Mm To 4Mm With 4 F Sheath Compatibility Across Sizes. Monorail / Over The Wire. , Balloons - Large Diameter For Vessel Diameters Of 12Mm And Above Should Be Non-Compliant And Have Low Deflation Time Balloon Material Should Be Lubriciously Coated With Scratch / Puncture Resistant Balloon Material Min. Sheath Compatibility Of 7F. , Peripheral Cutting Balloon Should Have Choice Of Diameter Range From 5Mm To 8Mm Should Have Micro Surgical Blades ( Atherotome ) On Non Compliant Balloon Only Bigger Diameter Cutting Balloons ( 5 - 8Mm ) With 2Cm Atherotome Should Be 0.018 Wire Compatible With Otw Delivery System Exposed Atherotome Height To Be Not More Than 0.005 , Occlusion Balloon Should Be Soft Compliant Balloon Material With Radiopaque Markers At Both Distal And Proximal End Of Balloon Should Be 14F / 16F Sheath And 0.035 / 0.038 Wire Compatible With Balloon Diameter Of 20Mm, 27Mm, 33Mm And 40 Mm , Guidewires - 0.018 / 0.014 Should Have Glidex Hydrophilic Distal Coating For Negotiating Tortous Anatomy And Colateral Approach. Should Be Available In Both 0.018 And 0.014. Should Provide Excellent Support Like A 0.035 In A 0.018 / 0.014 Wire Single Piece Core Design To Have Better Steerability, Pushability And Torque Transmission , Amplatz Super Stiff Wires - 0.035, 0.038 Should Have Stiff Core, Super Stiff Wire Body, Atraumatic Tip With Gradual Distal Core Taper Should Have Ptfe / Teflon Coating For Reduced Friction During Catheter Tracking. Should Support Catheter Exchange Should Have Flat Coiled Outer Wire Construction For Larger Inner Core And Hence Greater Support , Hydrophilic Marker Wire - 0.035 Should Have Single Piece Core With Radiopaque Polyurethane Jacket And Glidex Coated Hydrophilic Coating 4 Distal Paltinum Magic Markers Spaced At 1Cm For Improved Visualization Single Piece Core Design To Have Better Steerability, Pushability And Torque Transmission , Cto Wire 0.014 0.014 Weighted Tip Cto Guide Wire With Stainless Steel Core Hydrophilic & Hydrophobic Coating Tip Load-12Gm , 18 Gm , 25 Gm , 30 Gm Us Fda Approved Wire Lengths - 190 Cm & 300Cm , Cto Wire 0.018 0.018 Weighted Tip Cto Guide Wire With Stainless Steel Core Hydrophilic & Hydrophobic Coating Tip Load-12Gm , 18 Gm , 25 Gm , 30 Gm Us Fda Approved Wire Lengths - 190 Cm & 300Cm , 0.014 Peripheral Wire Stainless Steel Core Wire Hydrophilic & Hydrophobic Coating Tip Load-3Gm & 6 Gm Us Fda Approved Wire Lengths - 190 Cm & 300Cm , 0.018 Peripheral Wire 0.018 Guide Wire With Stainless Steel Core Hydrophilic & Hydrophobic Coating Tip Load- 7.6 Gm , 6.5 Gm Us Fda Approved Wire Lengths -150 Cm , 200 Cm & 300Cm , Backup Meir Wire - 0.035 • Should Have Extra Stiff Shaft To Support Aaa Device • Should Have Very Flexible And Soft Distal Tip To Avoid Aortic Perforation / Vessel Trauma • Should Have Radiopaque Tip For Excellent Visibility, Ptfe Coated Proximal Shaft For Frictionless Advancement • Sholud Have Choice Of J And C Tip Shape With 185Cm And 260 / 300Cm , Guide Catheters - 6F, 7F, 8F Choice Of 16 Tip Shapes Amongst Indusry Standard Shapes In 55Cm And 90Cm Should Have Excellent Backup Support And Shape Retention Tungsten Atraumatic, Radiopaque Soft Tip Should Have Round Double Wire Braided Construction For Better Torque, Large Inner Lumen With Soft Tapered Tip Ptfe Inner Liner ( For Smooth Passage Of Devices ) And Polyether-Ester Polymer Outer Coating ( For Shape Retention ) , Support Catheter Catheter For Crossing Chronic Total Occlusions In Peripheral Arteries- Fda / Ce Mark Approved Various Sizes , 0.014 , 0.018, 0.035 , Micro Punture Set Accustick Ii Introducer ( 4F Coaxial Dilator / 6F Sheath With Ro ) With Locking Stiffening Cannula Anddiagnosticneedle With Stylet 21G + 0.038 J -Tip And 0.018 Nitinol Wire , Detachable Coil 0.018 Interlock Detachable Platinum Fibered Coil For Peripheral Use , 0.018 Assorted Sizes .Dia 3Mm -14 Mm . Assorted Lengths , Detachable Coil 0.035 Interlock Detachable Platinum Fibered Coil For Peripheral Use , 0.035 Assorted Sizes Dia 3Mm- 20 Mm, Assorted Lengths , Pushablevortx 18 Coil Pushable 0.018 System Platinum Vortx Coils 3 To 6 Mm In Diameter Of Assorted Length , Pushable18 Coil Pushable Platinum 0.018 System Coils, 3-6 Mm Diameter Of Assorted Lenghts , Pushablevortx 35 Coil Pushable Platinum Vortx0.035 System Coils Upto 3 To 9 Mm In Diameter Of Assorted Lenghts , Pushable35 Coil Pushable Platinum 0.035 System Coils Upto 3 To 9 Mm In Diameter Of Assorted Lenghts , Pva Particle Polyvinyl Alcohol Particles 350-500 Microns , Pva Particle Polyvinyl Alcohol Particles 500-700 Microns , Pva Particle Polyvinyl Alcohol Particles 150-250 Microns , Pva Particle Polyvinyl Alcohol Particles 45-150 Microns , Drug Eluting Beads D C Bead - Loadable Hydrogel Microspheres That Are Biocompatible, Hydrophilic, Non-Resorbable, And Precisely Calibrated And Approved For Loading With Doxorubicin And Irinotecan, Available In Size Range Of 70Um - 700Um. , Torquable Pre Shaped Superselectivemicrocatheter Torquablemicrocatheter For Peripheral Embolization, Made Of Nitinolhypotube And Hydrophilictip. Id 0.021 With Different Shapes. ( Bern, J, Swan & Strait ) , Microcatheter For Peripheral Embolization Stainless Steel Braided Microcatheter With Hydrophilic Coating For Peripheral Coil Embolization. Id 0.021 Manually Shapeable Tip , Hi-Flow Microcatheter For Peripheral Embolization Fiber Braided High Flow Microcatheter Od 2.8Fr / Id 0.027 Permiting 710 Micron Pva Particle & 5520 Kpi Burst Pressure. Dmso & Alcohol Compatible , Torquablesuperselectivemicrocatheter With Guidewire Torquablemicrocathetermede Of Nitinolhypotube With Hydrophilic Shapable Tip. Id 0.021 With 0.014 Manually Shapable&Reshapable Tip Wire Guide For Superselective Peripheral Embolization , Hi-Flow Microcatheter For Peripheral Embolization With Guide Wire Fiber Braided High Flow Microcatheter Od 2.8Fr / Id 0.027 Permiting 710 Micron Pva Particle & 5520 Kpi Burst Pressure With Hydrophilic Shapable Tip. Id 0.021 With 0.016 High Torque Control Dimond Cut Nitinolhypotube, Shapable Tip Micro Wire. Dmso & Alcohol Compatible , Peripheral Imaging Ivus Catheter 0.018 Peripheral Imaging Catheter ( Ivus ) With 30 Mhz Frequency To Image Large Peripheral Vessels , Pharmaco Mechanical Thrombolysisdevice / Catheter Pharmaco Mechanical Thrombolysisdevice / Catheterwith Active Infusion Ofthromblytic Agentand Aspiration Suctionin Same Catheter .Dia -4F , 6F , 8F , Power Pulse Kit Angiojet Ultra Power Pulse Kit , Group E: Items For Bmv Procedure And Pulmonary Valve Dilation , Brocken Brough Needle ( Transeptal ) , L.A. Wire, Stylet, Ruler, Syringe, Streching Tube ( Balloon Kit ) , Baloon Size 20-30 Mm Innoue , Baloon Size 20-30 Mmaccura , Baloon Size 20-30 Mm Sym / Equivalent , Mullen Sheath , Baloon Shaper , Septal Dilator , Exchange Length Terumo Wire , Tyshak Balloon ( 9-12 ) , Tyshak Balloon Compatible Extra Stiff Wire ( 021 & 025 ) , Valver Balloon , Balloon ( Innoue ) With Accessories ( Brocken Brough Needle ( Transeptal ) , L.A. Wire, Stylet, Ruler, Syringe, Streching Tube ( Balloon Kit ) , Mullen Sheath, Baloon Shaper, Septal Dilator, Exchange Length Terumo Wire ) , Balloon ( Accura With Accessories ) ( Brocken Brough Needle ( Transeptal ) , L.A. Wire, Stylet, Ruler, Syringe, Streching Tube ( Balloon Kit ) , Mullen Sheath, Baloon Shaper, Septal Dilator, Exchange Length Terumo Wire ) , Balloon For Pulmonary Valve Dilation , Group F , ( A ) Asd Closure Devices With Delivery System – Us Fda / Ce & Dcgi Approved • Approved For Pediatric / Adult Use • Device Made Of Biologically Inert Material • Self-Centering, Detachable Device With Delivery Cable • Available In All The Sizes ( 6 Mm – 40 Mm ) ( B ) Titanium Nitride Coated Asd Closure Device With Delivery System -Approved For Pediatric / Adult Use -Device Made Up Of Biologically Inert Material -Available In All Sizes ( 06Mm To 42Mm ) -Titanium Nitride ( Tin ) Coating Should Be There To Prevent Nickel Leaching. -Should Come With Compatible Delivery System , Asd Closure Devices Without Delivery System – Us Fda / Ce & Dcgi Approved • Approved For Pediatric / Adult Use • Device Made Of Biologically Inert Material • Self-Centering, Detachable Device With Delivery Cable • Available In All The Sizes ( 6 Mm – 40 Mm ) , Delivery Sheath For Asd Closure Device – Us Fda / Ce & Dcgi Approved • Compatible With The Device Approved In Item No. 1, 2 , ( A ) Left Atrial Appensage Closure Device Us Fda / Ce & Dcgi Approved ( B ) • Titanium Nitride Coated Left Atrial Apendage Closure Device: • Us Fda / Ce & Dcgi Approved • -Should Be Able To Close Single Lobed And Multiple Lobed Appendages. • -Low Profile • -Should Be Compatible To All The Laa Anatomy • Titanium Nitride Coated Vsd Closure Device With Delivery System • -Approved For Pediatric / Adult Use • -Device Made Up Of Biologically Inert Material • -Available In All Sizes ( 06Mm To 24Mm ) • -Titanium Nitride ( Tin ) Coating Should Be There To Prevent Nickel Leaching. ( C ) -Should Come With Compatible Delivery System , Sizing Balloon For Device Closure – Circular Shape Us Fda / Ce & Dcgi Approved , Sizing Balloon For Device Closure – Oval Shaped - Us Fda / Ce & Dcgi Approved , Sizing Plate For Device Closure- Us Fda / Ce & Dcgi Approved , Delivery Cable For Asd / Vsd / Pda Devices - Us Fda / Ce & Dcgi Approved , Retrievers For Asd / Vsd / Pda Devices - Us Fda / Ce & Dcgi Approved , Seath For Retrival Of Devices - Us Fda / Ce & Dcgi Approved , ( A ) Vsd Closure Devices With Delivery System – Us Fda / Ce & Dcgi Approved • Approved For Pediatric / Adult Use • Device Made Of Biologically Inert Material • Self-Centering, Detachable Device With Delivery Cable • Available In All The Sizes ( 6 Mm – 40 Mm ) ( B ) Titanium Nitride Coated Vsd Closure Device With Delivery System -Approved For Pediatric / Adult Use -Device Made Up Of Biologically Inert Material -Available In All Sizes ( 06Mm To 24Mm ) -Titanium Nitride ( Tin ) Coating Should Be There To Prevent Nickel Leaching. -Should Come With Compatible Delivery System , ( A ) Pda Closure Devices With Delivery System – Us Fda / Ce & Dcgi Approved • Approved For Pediatric / Adult Use • Device Made Of Biologically Inert Material • Self-Centering, Detachable Device With Delivery Cable • Available In All The Sizes ( B ) Titanium Nitride Coated Pda Closure Device With Delivery System -Approved For Pediatric / Adult Use -Device Made Up Of Biologically Inert Material -Available In All Sizes ( 03-05Mm To 20-22Mm ) -Titanium Nitride ( Tin ) Coating Should Be There To Prevent Nickel Leaching. -Should Come With Compatible Delivery System , Pda Closure Devices Without Delivery System – Us Fda / Ce & Dcgi Approved , Embolisation Coils ( 0.018 Inch ) - Us Fda / Ce & Dcgi Approved • Sizes Ranging From 2 X 2 To 15 X 15 , Embolisation Coils ( 0.035 Inch ) - Us Fda / Ce & Dcgi Approved • Sizes Ranging From 2 X 2 To 15 X 15 , Embolisation Coils ( 0.052 Inch ) - Us Fda / Ce & Dcgi Approved • Sizes Ranging From 2 X 2 To 15 X 15 , Embolisation Plugs And Foam , Introducer System For Laa Closure With The Double Angulation Of 45° & 30° Containing I ) Delivery Sheath With Back Bleed Prevention Hemostatic Valve And Side Port, Ii ) Dilator, Iii ) Delivery Cable, Iv ) Loader. 8 / 9 / 10Fr. , Multifunctional Occluder -For Occlusion Of Muscular Vsd, Perimembranous Vsd, Rsov, Apex Window & Av Fistula - Should Be Low Profile ( 4F-6F ) -Should Come With Aelongatable Waist And Can Be Used In Retrograde And Antegrade Approach. , Self-Expandablenitinol Stent With Radial Force Fixation, E Ptfe Dual Membrane Coating For ( Excellent Biocompatibility And Durability Andno Suture On The Main Body To Prevent Pin Hole Leakage ) . Spine – Connecting Bar – ( Gives Axial Support , - Avoids Shortening ) . Size Od - 20Mm To 44Mm; Length - 80Mm, 100Mm, 120Mm, 140Mm 160Mm And 200Mm. Tapering - 4 / 6 / 8Mm , Specifically Designed For Endovascular To Exclusion Abdominal Aortic Aneurysm. A Self-Expandable Nitinol Stent With Eptfe Dual Membrane Coating. No Suture On The Main Body To Prevent Pin Hole Leakage. Od - 22Mm To 34Mm, Length - 120Mm Main Body , Iliac Stent Graft Endovascular Stent Graft Device For The Treatment Iliac Aneurysm Or Dissection. With Proximal Bare Spring Configuration. It Should Be An Extension To Aaa Graft System. Od - 10Mm To 18Mm Length - 60Mm To 120Mm , Peripheral Snare With Tungesten Loop Coated With Titanium Nitride ( 5Mm To 35Mm ) Having A Nitinol Shaft With The Length Of 120Cm. Type - Goose Neck. , Coronary Snare Withtungsten Loop Coated With Titanium Nitride ( 4Mm & 7Mm ) Having Nitinol Shaft With The Length Of 200Cm. Type - Goose Neck , Steerable Sheath With Deflectable Tip ( 90-180 Degree ) Size Available Upto - 5 / 6 / 7 / 8 / 9 / 10 / 12 / 14Fr. In 80Cm 90Cm Length , Aui Stent Graft System Specifically Designed For Treatment Of Endovascular Abdominal Aortic Aneurysm. A Self-Expandable Nitinol Stent With Eptfe Dual Membrane Coating With Connecting Spine Bar For Flexibility & Offers Axial Supportpreventing Foreshortening Of Stent. , Group G: Miscellaneous Item , Intravascular Retriever – Snare ( ‘Amplatz Gooseneck’ Type ) - Us Fda / Ce & Dcgi Approved Snare Kit Should Include • A Snare And Its Compatible Sheath • Should Have Nitinol Shaft • Should Have 90 Degree Preformed Snare Loop • Variable Sizes Of Loop ( 5-35 Mm ) , Sheaths For Intravascular Snares - Us Fda / Ce & Dcgi Approved , Vertebral Catheter - Us Fda / Ce & Dcgi Approved • In Various Standard Lengths And Curves , Coeliac Axis Catheter - Us Fda / Ce & Dcgi Approved • In Various Standard Lengths And Curves / Cobra Catheter , Shepherd’S Hook Catheter- Us Fda / Ce & Dcgi Approved • In Various Standard Lengths And Curves , Microcatheter ( Coiled Stainless Steel Construction ) - Us Fda / Ce & Dcgi Approved • In Various Standard Lengths And Curves • 2-3.8 F Size • .010-.022 Inch Wire Compatible • With Radio-Opaque Marker At Tip , High Pressure Angioplasty Balloon For Peripheral Vascular Use – Us Fda / Ce & Dcgi Approved • Should Have Rated Burst Pressure = 14 Atmosphere • Should Have Hydrophilic Coating • Should Be Available In Various Outer Diameters And Balloon Lengths And Various Shaft Lengths , Peripheral Stent Balloon Expandable ( Otw / Rx ) – Us Fda / Ce & Dcgi Approved • Should Be 0.035” Compatible • Should Be Made Of Cobalt Chromium • Should Be Quoted Either In Open Cell Or Closed Cell Design • Should Be Available In Various Balloon Ods • Should Have Balloon / Stent Lengths Available • Should Have A Shaft Lengths Of 75-135 Cm , Self-Expanding Peripheral Stent – Us Fda / Ce & Dcgi Approved • Should Be 0.014 / 0.018” Compatible • Should Over The Wire • Should Be Made Of Nitinol • Should Have The Least Lesion Crossing Profile For All Stent Diameters • Should Be Available In Various Stent Diameters Of 6-10 Mm • Should Be Available In Various Stent Lengths > 60 Mm • Should Have A Shaft Lengths Of At Least 110 Cm , Ivc Filter – Us Fda / Ce & Dcgi Approved , Ivus Catheter Compatible With System In Cath Lab Of Pbm Hospital Bikaner ( Boston Scientific ) , Ffr Catheter Compatible With St. Jude System , Rota Burr ( All Size ) , Rota Wire , Rotapro Pre Connected Exchangable Burr Catheter ( Rota Advancer And Burr ) - Us Fda Approved ( Compatible With Rotapro Machine ) . , Ivl Cathetar , Iabp Cathetar And Accessories , Bib ( Balloon In Balloon ) Type Balloons For Coarctation Dilatation-Us Fda& Ce And Dcgi Approved • Monorail ( Rapid Exchange ) And Over-The-Wire ( Otw ) Balloons Available In The Sizes And Lengths , Z Med Type Balloon For Aortic Coactation – Us Fda / Ce And Dcgi Approved • 5 To 20 Cm Diameter In All Sizes Otw / Rapid Exchange, Compatible With 0.014” / 0.035” And 0.038” Wire , ( A ) Impella Hemodynamic Support Catheter2.5 ( B ) Impella Hemodynamic Support Catheter5 ( C ) Impella Hemodynamic Support Cathetercp ( D ) Impella Hemodynamic Support Catheterrp , Acist Ivus Catheter • With Dual Frequency 40 / 60 Mhz In Single Catheter • Single Catheter For Both Coronary And Peripheral • Lubricious Hydrophilic Coating Supports Faster Pullback Speed Up To 10 Mm / Sec For Minimizing Ischemic Risk • With Novel Offset To Design, Variflex Imaging Window. , Savvy Sensor Guided Tavi Wire Single Wire Working As A Guide Wire, For Hemodynamic Measurement And For Rapid Lv Pacing , Optowire A Hybrid Nitinol / Stainless Steel Pressure Sensing Guided Wire Powered By Fidela • Patented Optical Pressure Sensor Mounted Proximal To 3 Cm Long Radioopaque • Measure Physiologic Indices Including •Ffr & Diastolic Pressure Radio ( Dpr ) • Wire With Diameter Of .014 And Length Of 180 Cm • Operating Pressure Of -30 To + 300 Mmhg , Consumables For Tavi ( A ) Balloon Expandable With All Required Accessories ( B ) Self Expandable With All Required Assessories , Fine Cross Micro Catheter ( Braided & Coil Construction Must Have Along With Distal Hydrophilic Coating ) To Be Used For Cto Antegrade And Retrograde Approach , Guide Extansion Catheter Us Fda Approved , Group H: Pace Maker , Vvirpacemaker Us Fda / Ce & Dcgi Approved Permanent Pacemakers With All Leads And Accessories With Life Time Warranty Mri Compatible 3 Tesla , Vvirpacemaker Us Fda / Ce & Dcgi Approved Digital Multi-Programmable Pacemaker.Mode: Single Chamber: Vvir / Aair. With Beat To Beat Auto Capture And Proven Longevity Of >9.5 Years With 100% Pacing Of Ra / Rv @2.5Volts. Digital High Sampling Rate Of P / R Wave And Automated Ventricular Rate Stabilization During Af. With 6F Compatible Passive-Fixation Tined Lead Or Screw In Lead & Lead Introducer & Dual Rate Responsive Sensors With Life Time Warranty. Mri Compatible 3 Tesla , Vdd / Vddr Pacemaker Us Fda / Ce & Dcgi Approved Permanent Pacemakers With All Leads And Accessories With Life Time Warranty Mri Compatible 3 Tesla , Dddr Pacemaker Us Fda / Ce & Dcgi Approved Permanent Pacemakers With All Leads And Accessories With Life Time Warranty Mri Compatible 3 Tesla , Dddr Pacemaker Us Fda / Ce & Dcgi Approved Digital Multi-Programmable Pacemaker Mode: Dual Chamber: Dddr. With Features Of Automatic Threshold Check, Auto Adjusting Of Av Delay ( Extendable Upto 400 Ms ) , And Automatic Intrinsic Activity Search. With Beat To Beat Auto Capture And Proven Longevity Of >10 Years With 100% Pacing Of Ra & Rv At 2.5 Volts. With 6F Compatible Passive-Fixation Tined Leads Or Screw In Leads & Lead Introducers & Dual Rate Responsive Sensors With Life Time Warranty. Mri Compatible 3 Tesla , Dddr Pacemaker Us Fda / Ce & Dcgi Approved Permanent Pacemakers For Physiological Pacing ( His Bundle And Left Bundle Pacing ) With All Leads And Accessories With Life Time Warranty Mri Compatible 3 Tesla , ( A ) Physiological Pacing Lead ( His Bundle And Left Bundle Pacing ) & All Accessories 3Tmri Compitableus Fda / Ce & Dcgi Approved ( B ) Lumenless Lead Fda Approved Lead For His Bundle Pacing And Lbbap , Dddr Pacemaker Us Fda / Ce & Dcgi Approved Digital Multi-Programmable Pacemaker Mode: Dual Chamber: Dddr. With Features Of Automatic Threshold Check, Auto Adjusting Of Av Delay ( Extendable Upto 400 Ms ) , And Automatic Intrinsic Activity Search. With Beat To Beat Auto Capture, With 6F Compatible Passive-Fixation Tined Leads Or Screw In Leads & Lead Introducers & Dual Rate Responsive Sensors With Life Time Warranty. Mri Compatible 3 Tesla , Aicd Single Chamber Pacemaker With All Leads Us Fda / Ce & Dcgi Approved, Icd With All Leads And All Accessories • Single Chamber • All Basic Programmable Parameters • Must Be Mr Conditional. • Must Have Facility Of Atp Befor Charging For Defibrillation • All Basic Programmable Parameters With Shock Reduction Technology Comprising Of Svt, T-Wave, Rv-Noise Discrimination Features. • Must Have Facility Of Rf / Distance Telemetry Programming • Rv Lead Must Be 9F Of Less In Size And Have Proven Performance Of 5 Years. • Lead Should Be Steroid Eluting And Df-1 & Df-4 Compatible • Mri Compatible 3 Tesla • Warranty Shoud Not Be Less Than 10 Years , Aicd Dual Chamber Pacemaker With All Leads Us Fda / Ce & Dcgi Approved, Icd With All Leads And All Accessories • Dual Chamber • All Basic Programmable Parameters • Must Be Mr Conditional • Must Have Acility Of Atp Befor Charging For Defibrillation • All Basic Programmable Parameters With Shock Reduction Technology Comprising Of Svt, T-Wave, Rv-Noise Discrimination Features. • Must Have Facility Of Rf / Distance Telemetry Programming • Rv Lead Most Be 9F Or Less In Size And Have Proven Performance Of 5 Years • Must Have Algorithm Of Automatic Conversion From Aair To Dddr And Vice Versa ( For Minimize Ventricular Pacing ) • Must Have Algorithm For Management Of Neuro Cardiogenic Syncope • Must Have Automatic Threshold Management For Patient Safety. • Mri Compatible 3 Tesla • Warranty Shoud Not Be Less Than 8 Years , Biventricular Pacemaker With All Accessories And Leads Us Fda / Ce & Dcgi Approved, Biventricular Pacemaker With Atrial, Rv, Lv Leads And All Accessories Required During Imlantation • Must Have Separate Programmable Rv, Lv Lead Amplitude, Pulse Width And Vv Delay • Must Have Facility For Egm Based Optimization Of Av, Pv And Vv Delays • Must Have Quadripolar Lead For Lv Pacing • Must Have Fluid Monitoring System • Must Have Facility For Active Fixation Of Lv Lead In C S ( Either Screwing Ordeployable Lobes With Anchor Mechanism ) • Must Have Mri Compatible • Company Must Quote Only The Latest Model Of Devices Commercially Available • Mri Compatible 3 Tesla , Combo Device ( Crt-D ) With Quadripolar Lv Lead And Df-1 Rv Lead Must Be 3T Full Body Mri Conditional Must Have Atleast 17 Pacing Vectors In Lv Lead Must Have Rate Responsive Feature With Mv Sensor Must Have Battery Capacity Of More Than 1.8 Ampere Hour Warranty Of Atleast 6 ( 4+2 ) Years , Biventricular Pacemaker + Icd With All Leads Us Fda / Ce & Dcgi Approved, Biventricular Pacemaker + Icd ( Combo Device ) With Atrial, Rv, Lv Leads And All Accessories Required During Imlantation • Must Have All Basic Programmable Parameters • Must Have Quadripolar Lead For Lv Pacing • Facility Of Atp During Charging For Defibrillation • Must Have Fluid Monitoring System • Must Have Separate Programmable Rv, Lv Lead Amplitude, Pulse Width And Vv Delay. • Must Have Algorithm For Af Suppression With Programmable Automatic Mode Switch Basal Rate. • Must Have Facility For Automatic Lv Only And B / V Pacing And Automatic Av, Vv Delay • The Size Of Atrial And Rv Lead Must Be Df-4 Compatible And Lv Lead Quadripolar • Must Have Mri Compatible • Company Must Quote Only The Latest Model Of Devices Commercially Available. • Mri Compatible 3 Tesla , Remote Monitoring Device With International Roaming • Must Have Automatic Hands Free Transmission For Patients • Must Have Physician Friendly Colour Coded Urgency Settings • Must Be Compatible With Standard Internet Settings • Interrogation Capabilities Should Be Compatible With In Office Follow Up • Alert Notification Should Be Available As Text Messages On Mobile • Direct Presence Of Parent Company In India ( Not Only Through The Distributors ) And Company Must Provide Its Trained Technical Person For Each Implantation Whenever Required And For Follow Up Programming When It Is Required • Company Must Provide At Least One Programmer Exclusively To The Cardiology Dept • Company Must Quote Only The Latest Model Of Devices Commercially Available , Implantable Loop Recorder • Must Be Able To Detect Asytole, Brady-Arrhythmia And Vt / Fvt • Must Have The Storage Capacity Of >45 Minutes • Must Have Dynamic Sensing Threshold For R Wave Sensing Along With Noise Reversion • Must Have A Patient Tool For Symptomatic Recording • Must Have At Least 35 Months Of Longevity • Must Be Compatible With Remote Monitoring Device • Direct Presence Of Parent Company In India ( Not Only Through The Distributors ) And Company Must Provide Its Trained Technical Person For Each Implantation Whenever Required And For Follow Up Programming When It Is Required • Company Must Provide At Least One Programmer Exclusively To The Cardiology Dept • Company Must Quote Only The Latest Model Of Devices Commercially Available , Implantable Loop Recorder For Af Detection • Must Be Able To Detect Asystole, Brady-Arrhythmia And Vt / Fvt And At / Af • Must Have The Storage Capacity Of >45 Minutes • Must Have Dynamic Sensing Threshold For R Wave Sensing Along With Noise Reversion • Must Have A Patient Tool For Symptomatic Recording Along With Alerts • Must Be Able To Give Af Burden Reports To Monitor The Progress Of Chronic Af Patients • Must Have At Least 35 Months Of Longevity • Must Be Compatible With Remote Monitoring Device • Direct Presence Of Parent Company In India ( Not Only Through The Distributors ) And Company Must Provide Its Trained Technical Person For Each Implantation Whenever Required And For Follow Up Programming When It Is Required • Company Must Provide At Least One Programmer Exclusively To The Cardiology Dept • Company Must Quote Only The Latest Model Of Devices Commercially Available , Mobile Cardiac Telementry System For Arrhythmia Diagnosis • Must Have 7 Days Rhythm Monitoring With Active Life • Must Collect Ecgs Automatically For • Bradycardia And Tachycardia • Pause / Asystole • Atrial Fibrillation • Vt / Vf , Us Fda / Ce & Dcgi Approved, Biventricular Pacemaker + Icd ( Combo Device ) Without Lead , Us Fda / Ce & Dcgi Approved, Biventricular Pacemaker ( Crt ) Without Lead , Us Fda / Ce & Dcgi Approved, Aicd Dual Chamber Pacemaker Without Lead , Us Fda / Ce & Dcgi Approved, Aicd Single Chamber Pacemaker Without Lead , Us Fda / Ce & Dcgi Approved Dddr Permanent Pacemakers Without Lead , Us Fda / Ce & Dcgi Approved Vdd / Vddr Permanent Pacemakers Without Leads , Us Fda / Ce & Dcgi Approved Ddd Permanent Pacemakers Without Lead , Us Fda / Ce & Dcgi Approvedvvi Permanent Pacemakers Without Lead , Us Fda / Ce & Dcgi Approved Vvir Permanent Pacemakers Without Leads , Atrial Lead&All Accessories For Biventricular Pacemaker ( Crt ) , Us Fda / Ce & Dcgi Approved , Rv Leadall &Accessories For Biventricular Pacemaker ( Crt ) , Us Fda / Ce & Dcgi Approved , Lv Leadall &Accessories For Biventricular Pacemaker ( Crt ) , Us Fda / Ce & Dcgi Approved , Atrial Leadfor Biventricular Pacemaker + Icd ( Combo Device ) With All Accessories Required During Imlantation Us Fda / Ce & Dcgi Approved , Rv Leadfor Biventricular Pacemaker + Icd ( Combo Device ) With All Accessories Required During Imlantation Us Fda / Ce & Dcgi Approved , Lv Leadfor Biventricular Pacemaker + Icd ( Combo Device ) With All Accessories Required During Imlantation Us Fda / Ce & Dcgi Approved , Rv Lead For Aicd Single Chamber, Us Fda / Ce & Dcgi Approved , Pacing Leads For Aicd Dual Chamber, Us Fda / Ce & Dcgi Approved , Atrial Leadpacing Lead For Dddr Permanent Pacemakers Us Fda / Ce & Dcgi Approved , Ventricular Leadpacing Lead For Dddr Permanent Pacemakers Us Fda / Ce & Dcgi Approved , Atrial Leadpacing Lead For Dddpermanent Pacemakers Us Fda / Ce & Dcgi Approved , Ventricular Leadpacing Lead For Dddpermanent Pacemakers Us Fda / Ce & Dcgi Approved , Pacing Leads For Vdd / Vddr Pacemakers Us Fda / Ce & Dcgi Approved , Pacing Leads For Vvi / Vvir Pacemakersus Fda / Ce & Dcgi Approved , Epicardial Lead For Pacemakersus Fda / Ce & Dcgi Approved , Temporary Pacing Leads - Us Fda / Ce & Dcgi Approved 1. Should Be Us Fda & Dcgi Approved 2. Should Have 10 Cm Depth Markers To Enhance Placement. 3. Should Have Smooth, Polyurethane Hemocompatible Coating. 4. Should Have Clearly Marked Terminals. 5. Should Have Shrouded 2 Mm Pin Connector Leads. 6. Should Have Stainless Steel Centre Conductor And Stainless Steel Electrodes. 7. It Should Have Solid Core Enables User To Customize The Curve. 8. Should Have Optimal Torque Control For Challenging Anatomy , Temporary Pacing Leads: Balloon Floatable – Us Fda / Ce & Dcgi Approved 1. Should Be Us Fda & Dcgi Approved 2. Should Be Latex Balloon Tipped, Flow Guided For Stable Insertion. 3. Should Have 10 Cm Depth Markers To Enhance Placement. 4. Should Have Smooth, Polyurethane Hemocompatible Coating. 5. Should Have Clearly Marked Terminals. 6. Should Have Shrouded 2 Mm Pin Connector Leads. 7. Should Have Platinum Electrodes 8. It Should Have Flexible Tip Design For Delicate Placement. , Temporary Pacing Leads With Stylet - Us Fda / Ce & Dcgi Approved , Pulse Generator ( Temporary ) , Lead Extraction System Of Different Variety , Vvi / Vvir Leadless Pacemaker With All Accessories Us Fda Approved / 7Years Warranty Permanent Leadless Pacing Capsule Providing Vvi / Vvir Pacing The Weight Of The Device Should Be Less Than 2Gms And Volume Less Than 1 Cc Must Be Mri Conditional Pacemaker For Full Body Scan - 1.5T & 3T Must Have Ventricular Capture Management Should Have The Ability To Transmit Data Through Remote Moniter. , Vdd Leadless Pacemaker With All Accessories Us Fda Approved / 7 Years Warranty Permanent Leadless Pacing Capsule Providing Vvi / Vvir / Vdd Pacing The Weight Of The Device Should Be Less Than 2Gms And Volume Less Than 1 Cc Must Be Mri Conditional Pacemaker For Full Body Scan - 1.5T & 3T Must Have Ventricular Capture Management Should Have The Ability To Transmit Data Through Remote Moniter , Subcutaneous Icd 3Tesla Mri Compitable , Group I Diagnostic Ep Catheters , Deflect. Decaduapolar ( 20 Poles ) For A Flutter ---- All Diameters , Deflectable Decapolar ( 10 ) ( Pulm. Vein ) --- All Diameters , Defectable Decaduapolar ( 20 ) ( Pulm. Vein ) --- All Diameters , 2F Multipolar ( > Ten Electrodes ) For Mapping Through Coronary Vasculature , Basket Catheter With Accessory , Crista Catheter With Accessory , Other Special Ep Catheters , Pacing Catheter With Angiogrophic Capability • Variable Sizes • Bipolar Or Quadripolar With Appropriate Cable • Cvp Monitoring & Angiographic Facility , Pediatric Use : All The Above Catheters, Sheaths Etc For Pediatric Use. • Implying Smaller French Size Like 4F, 5F, With Certification For Use In Children , Pentapolar Diagnostic Catheter – Fixed Curve Catheter Material – Woven Electrode – Stainless Steel, Platinum, Paladium Quality Approval – - Us Fda / Ce & Dcgi Approved , Octapolar Diagnostic Catheter – Fixed Curve Catheter Material – Woven Electrode – Stainless Steel, Platinum, Paladium Quality Approval –- Us Fda / Ce & Dcgi Approved , 16 Pole Diagnostic Catheter – Fixed Curve Catheter Material – Woven Electrode – Stainless Steel, Platinum, Paladium Quality Approval – - Us Fda / Ce & Dcgi Approved , 20 Pole Diagnostic Catheter – Fixed Curve Catheter Material – Woven Electrode – Stainless Steel, Platinum, Paladium Quality Approval – - Us Fda / Ce & Dcgi Approved , 24 Pole Diagnostic Catheter – Fixed Curve Catheter Material – Woven Electrode – Stainless Steel, Platinum, Paladium Quality Approval – - Us Fda / Ce & Dcgi Approved , Bi-Directional Steerable Catheters Handle- Thumb Wheel Or Push Pull Automatic Curve Lock Mechanism Electrode – Stainless Steel, Platinum, Paladium Quality Approval – - Us Fda / Ce & Dcgi Approved , Atrial Mapping Catheters Electrode – Stainless Steel, Platinum, Paladium Quality Approval – - Us Fda / Ce & Dcgi Approved , Dual Curve Rf Ablation Catheter Bi-Directional Steerable Electrode – Stainless Steel, Platinum, Paladium Quality Approval – - Us Fda / Ce & Dcgi Approved , Reusable Defibrillation / Transcutaneous Pacing Patches ( Suitable For Equipment In Cath Lab, Ct2, Ct3, Ct6 ) , Disposable Defibrillation / Transcutaneous Pacing Patches ( Suitable For Equipment In Cath Lab, Ct2, Ct3, Ct6 ) , Defibrillation / Transcutaneous Pacing Patches For Use In Infants And Children , Cryo Catheters ( And Accessories ) For Ablation Of Arrhythmias In Children And Adults , Intracardiac Ultrasound / Echo Catheter For Guiding Rfa Compatible With The Existing Echo Machine At Pbm Hospital, Bikaner ( Quote All Prices Of The Catheters And Accessories ) , Disposable Electrocautery Patches For Rfa , Reusable Electrocautery Patches For Rfa , Magnetic Based Patches For Electro-Anatomical Mapping For Used With Ensite Precision Mapping System. , Velocity Array Catheter , Cool Pump Cable / Tubing Set , Sheaths Used In Ep Study And Rfa Sro Sl, Azulix , Bidirectional Sensor Enabled Contact Force Catheter Compatibable With Ensite Precision System With Assorted Curve. , Irrigated Bidirectional 16 Electrode High Density Sensor Enable Mapping Catheter Compatible With Ensite Precision System , Irrigated Bidirectional Ablation Catheter For 3D Mapping With Flexible Tip And Laser Cut Technology Compatible With Ensite Mapping System. , Irrigated Bidirectional Ablation Catheter For 3D Mapping With Flexible Tip And Laser Cuttechnology Compatible With Ensite Mapping System
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 10
14.
Power #10555136 Price Bid
Supply Of Various Electrical Items, Tool Kit Items, Fire Extinguishers, Electrical Insulated Checkered Rubber Matting For Dts, Main Lt Distribution Panels, Outdoor Dist Panels, Sub Dist Panel And Dg Sets At New Civil Sectt, Sgr Under Capex 2023-24 Supply Of Various Electrical Items, Tool Kit Items, Fire Extinguishers, Electrical Insulated Checkered Rubber Matting For Dts, Main Lt Distribution Panels, Outdoor Dist Panels, Sub Dist Panel And Dg Sets At New Civil Sectt, Sgr Under- Pddss2324100143 , Supply Of Bihexaganol 1/2 Inch Square Drive Socket Set,S-14Mxl (Taparia Make) 22 Sockets+5 Accessories Size:(8,9,10,11,12,13,14,15,16,17,18,19,20,21,22,23,24,25,26,27,28,29,30,31,32, Accessories 1753,1763,1773,1733,1715) , Supply Of Ring Spanner Set Of 12 Pc (Steel) Conforming To Is 2029-1998 (Taparia Product No. 1812) 12 Pcs Set Of Ring Spanners 6Mm To 32Mm Double Sided Box End Wrench (Pack Of 12) Size : (6-7)Mm,(8-9)Mm,(10-11)Mm,(12-13)Mm,(14-15)Mm,(16-17)Mm,(18-19)Mm,(20-22)Mm,(21-23)Mm,(24-27)Mm,(25-28)Mm,(30-32)Mm , Supply Of Double End Spanner Set Of 12 Pc (Double Sided Open End Wrench)(Material :Chrome Vanadium)Conforming To Is 2028-2004 (Taparia- Product No. Dep-12) Size 6X7,8X9,10X11,12X13,14X15,16X17,18X19,20X22 ,21X23,24X27,25X28, 30X32 , Supply Ofadjustable Wrench Spanner (1173-S-12)Inch Single Sided Open Wrench With Soft Grip- Chrome Plated (Taparia) , Supply Oflineman Pliers(Taparia 1621-8/1621-8N) , Supply Ofscrew Driver Set (Taparia) Product No. 831 Taparia Screwdriver Set With Neon Bulb-831/ Magnetic Tip ( 3.5 X 0.5, 4.3 X 0.6, 6 X 0.8, Philips No. 1, Philips No. 2, Poker Round, Poker Sq., Wooden Screw Type) , Supply Of Line Testers Yellow Product No. 813 Taparia , Supply Of Line Testers Yellow Product No. 816 Taparia , Supply Of 1000A Clamp Meter Ac/Dc Multifunction Clamp Meter Jaw Size: 60Mm : Ac/Dc Up To 1000A (Motwane Make) , Supply Of 630 Hydraulic Crimping Tool Alongwith Hexagonal Type Dies Dies H-50 To H-630 (11 Sets) (Jainson Tejas Tejas 630 With Foot Pump) Heavy Duty Hydraulic With Two Stage Setting Of High And Low Pressure For Quick Output . Compression Force 25 Metric Tonnes. Maximun Stroke 22 Mm. Operating Pressure 700 Kg/Sqcm Capacity : 50 Sqmm To 630 Sqmm , Supply Of Earth Resistance Meter (Clamp On Type) Modelfluke 1630-2 Fc , Supply Of Electrical Insulated Checkered Rubber Matting 3.3Kv 3Mm Thick(1Mtr X 2Mtr) Conforming To Is 15652:2006 Iec 61111 , Supply Of Abc Portable Dry Powder Fire Extinguishers 4 Kg , Supply Ofbox Type Socket Switch (Ss) Combined, 6 / 16A, 240V (Anchor/Ssk Or Equivalent Make) , Supply Of Multi Strand Heat Retardant & Flame Retardant, Single-Core, Pvc-Insulated, Copper Wire. 1.5 Sqmm (Polycab/Havells/ Imperial/Equivalent) (Coil=90 Mtr) , Supply Of Multi Strand Heat Retardant & Flame Retardant, Single-Core, Pvc-Insulated, Copper Wire. 2.5 Sqmm (Polycab/Havells/ Imperial/Equivalent) (Coil=90 Mtr) , Supply Of Multi Strand Heat Retardant & Flame Retardant, Single-Core, Pvc-Insulated, Copper Wire. 4 Sqmm (Polycab/Havells/ Imperial/Equivalent)(Coil=90 Mtr) , Supply Of 6 A, 3 Pin Top (Anchor Or Equivalent Make) , Supplyand Fixing Of3/4 Pvc Tape Isi Mark , Supply Of Coolant For Dg Set(Cummins/Volvoline/Shell Or Equivalent) , Supply Of M Oil For Dg Set(Viscosity 15 W-40 , Supply Of Led Lamps, Pin-Type 20W , Providing/Submission Of Geo-Tagged Coloured Photographs Of Subjected Work On A4 Sized Photopaper (4 Pic Per Page)
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Jammu And Kashmir View Result →
15.
Health and Family Welfare #10551414 Price Bid
Tender For Electrification Work In Phc Building At Palasani District Jodhpur - Electrical BSR 2022 Rajasthan) Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)inrecessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit & itsISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thickHot Dipped Galvanized Modular Box with earth terminal, 10A Modular switch,Modular face plate with grid plate, 3 pin ceiling rose / Holder /3 way connector, screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR. Short point (up to 3 mtr.) 2 Short point (up to 3 mtr.) 3 Medium point (up to 6 mtr.) 4 Long point(up to 10 mtr.) 5 Wiring of twin control light point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)in recessed ISI markedMMS ( IS:9537 P - III ) PVC conduit & its ISI marked (IS:3419-1988) accessories, round tiles, 2 Nos Hot Dipped Galvanized M.S Modularbox of 1.2 mm thickwith earth terminal,2 Nos10 A two way Modular switch, 3 pin ceiling rose / holder / 3 way connector ,Modular face plate with grid plate,screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR 6 Medium point (up to 6 mtr.) 7 Long point(up to 10 mtr.) 8 Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal sizeFR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) inrecessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & its ISI marked (IS:3419-1988)accessories, Hot Dipped GalvanizedModular box of 1.2 mm thick with earth terminal, 10 A modularswitch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR 9 On board 10 Supplying and fixing of power plug point with Modular accessories as per PWD specification for electrical Works, on hot dipped galvanized modular box of 1.2 mm thick with earthing terminal/connector on surface or in recessed with suitable size of modular face place with grid plate and cover plate including cost ofISI marked modular 16 amp. Switch (IS :3854) and 6/16 amp. socket outlet (IS:1293) making connection , testing , etc. as required. For specification ofWiring accessories refer ChapterE - 07related item & For additional technical parameters of product / work refer Annexure A attached with this BSR 11 Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 forlower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5,in existingsurface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure A attached with this BSR 12 3x 1.5 sq.mm 13 2 x 2.5 sq. mm. + 1x1.5sqmm 14 2 x 4.0 sq. mm. + 1 x 2.5 sq. mm. 15 4 x 10.0 sq.mm 16 4 x 6.0 sq.mm 17 1 x 2.5 sq.mm 18 Providing & Fixing of Recessed/surface mounting heavy duty horizontal type Double Door ( Metal / Glazed )Distribution board with Metal end box made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3, powder painted complete with reversible door (for double door DB only )100 amp. insulated copper bus bar/shorting link , copper neutral link, copper earth link , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, Ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 19 Metal door (Three phase) Per phase isolation, Horizontal IK-09 and IP-43 with Metal end box 20 6Way(Incomer 8,Sub Incomer2+2+2) 21 Metal door (single phase) IK-09 and IP-43 with Metal end box 22 16 Way (16+2) 23 Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load andsite requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting ofclass 3 as per IEC,minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted inexisting distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above ratingincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 24 Single pole MCB (With B/C curve tripping Characteristics) 25 6 A to 32 A rating 26 Four pole MCB (With B/C curve tripping Characteristics) 27 40 A rating 28 Double pole MCB(With B/C curve tripping Characteristics) 29 6 A to 32 A rating 30 S&F following sizes (dia.) of ISI marked virgin material MMS ( IS:9537 P - III ) PVC conduit along withISI marked (IS:3419-1988) accessories as requiredinrecessincludingcutting the wall, covering conduit and making good the same as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 31 20 mm 32 25 mm 33 P & F phenolic laminated sheet 2.0 mm thick of following size . Including screws, cup washer as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 34 75 mm dia 35 Providing & Fixing of modular type 120 W Step Fan regulator duly ISI marked (IS 11037:1984 ) with CM/L no. printedmade out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating ,includingall as per pre approved by Engineer in charge,making connections, testing etc. as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 36 5 step fan regulator 2 Module 360 dgree rotating 37 P & F 1.2mm thickM.S. Recessed fan box, hexagonal/ round of size 130 mm dia, depth 75mm,12 mm dia rod fan hook with 100 mmlength extended on each side . All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure A attached with this BSR 38 Providing & Fixing of Heavy duty capacitor start, copper woundDouble ball bearing900/1400 RPM single phaseExhaustfan conforming to IS:2312 ISI marked in existing opening including making connections testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 39 300 mm sweep(900/1400 RPM) 40 Providing & Fixing of IP20 SMD Mid Power LED batten type integrated light fixture made from Powder coated Extruded aluminiumhousing with in built driver, System lumen efficacy ≥ 110 lm/Watt output, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, CRI >80 , life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , Maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 41 1170mm(+/-10%) LED batten with min. lumen output 2200 lm 42 Providing & Fixing ofBEEStar rated copper wounded double ball bearing capacitor start, aluminium body & Metallicblade ceilingfanConforming to all the performance requirements laid down in IS 374:2019 including all amendments, as applicable ; & Carry BIS licensing (i.e. ISI marking) with down rod up to 80 cm with secondary support safety cable ( steel rope) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 43 1200 mm Sweep BEE 1 Star rated (service value >=4.0 to < 4.5 ) 44 Providing & Fixing ofof Double ball bearing, copper wounded capacitor startsingle phase metallicblade fresh air fan, in existing opening including cost of hardware , flexible 3 core copper conductor ,making connections, testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 45 225 mm sweep 46 Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed ArrmouredAluminiumcable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV withH4- Grade electrolyticaluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) includingtesting etc. as required of following size. OEM must have its own in house NABL accrediated Laboratory for testing procedure as per IS:10810.For additional technical parameters of product / work refer Annexure A attached with this BSR 47 25.0 Sq. mm 48 3.5 core 49 6.0 Sq. mm 50 2 core 51 Add Extra for Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV gradedirect in ground including excavation of trench of size 75 cm (Depth) x 35 cm(Width) ,with procedure as per followingpoints:- (a) Make a river sand bed of height 125 mm along the trench,(b) Lay the cable in the middle of the trench,(c) Provide river sand bed of height 125 mm on top of the cable, (d) Lay the protective Common burnt clay F.P.S. Bricks of Class designation 75 / Sand stone slabs of 50 mm thicknessand 225 mm widejust above the sand bed vertically across the cable ( Approx. 9 no. Bricks per Mtr.), (e) Backfill the excavated soil leaving 300 mm from the Ground level, (f)Lay the Cable warning tape and again back-fill the remaining portion of the trench upto the ground level and compacting the earth 52 Add Extra in item no. 11.1 to 11.4 for Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. 53 Up to 35 Sq.mm fixed with 25 mm x 2 mm thick suitable length red oxide and enamel painted MS clamp and base, pvc rawl plug and screws of sufficient size with spacing 0.6 Mtr. Between Clamps. 54 Supplyandinstallationofhigh tensile low carbon steel rod molecularly bonded with 99.9 % Copperthickness (250 microns) andconfirming toUL 467, IS/IEC 62561-2of following size and length and as per point mentioned (a), (b), [c), (d), (e) below :- 55 (a) Bore a hole of dia. 100 mm of required length, Place the rod in the centre of Hole 56 (b)filled with anti corrosiveconductivecompounds with the permanent sealings at both the ends, CPRI/ ERDAtested with RMS capacity of minimum 30 KA for withstanding 1 second .To ensure the moisture content and electrical conductivity, 25 kg for 2000 mm & 50 Kgs for 3000mm of resistance lowering earth enhancement material shall be used as a backfill compound. The compound shall be tested form NABL acredeated labfor lowresistivity ( less than 0.12 Ohm - meter ) & high conductivity in nature with carbon as a major contentas per referance of IS 3043-1987,IEEE 80-2013 (clause 14.5d) , IEEE 837 & IER 1956 with latest amendemnts 57 © Connect the rod with copper Strip/Conductor/Wire with suitable clamp made from tinned copper and SS 304 Bolt 58 (d) Place Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height250 to 300 mm. 59 (d)Testing of earth resistance for value of 5 ohms or lessas required & must record by engineer in charge during site visit and ensure to enter in measurment book. 60 (e) Test certificatesfor confirming above standards from OEM is mandatory. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 61 17.2 mm thick and 3 Mtr. Long 62 Supply & Laying following size earth wire in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles,making connection with GI/Cu purity purity >95%thimble etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 63 8 SWG G.I. ( Hot Dipped) Wire 64 Providing & Fixing of IK08, IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminummaterial with heat dissipation fins on housing with UV stabilized PC (UV stablization report submitted for UV cover ) /Toughened Glass coverand secondary lens on each LED & should be SMD type of 3 to 5 watt each . The System efficacy >=125 lm/ wt and potted driver& has a unique BIS R number withInput Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety , Power Factor >0.95 driverEfficiency >85%,THD(I) <10%Humidity 10% to 90% RH Working Temp -5C to 45C .driver current <750mA. The luminaireshall be BIS certified and Trade mark certified. Life ExpectancyEqual or more than 50000 burning hrs with Minimum 70% lumen maintened , CRI >70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external inside driver compartment. driver should be Phase to phase protection of 440 V for 4 Hrs.Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities forLED fixtures.(LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 65 LED Street Light fixture with Minimum lumen output 2450 lm 66 Providing & Fixing of Street light bracket made out from following size of B class , Medium class G.I. Pipe confirming to IS : 1239 P - 1 ( 2004 ) with heavy duty pole clamp, Saddles suitable fastners etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 67 25 mm Dia. 68 SITC of3 /4pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant materialhaving following current rating, short circuitbreaking capacityat 440/415 V, 50 Hz; O/L & S/C settings , conforming to IS/IEC 60947 P -2 :2003 with frontface and centralised adjustable, trip free mechanisum, true contact position indicator,line load interchangeability,designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree,pollution degree 3, having positive isolation capability, push(test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% Icu. U imp =8 KV, rated insulation voltage690 V.provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connectionsetc. as required.OEM shall have submitNABL / CPRI / ERDA accrediated lab type test certificate before execution All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 69 4 pole MCCB With Thermal Magnetic release 70 up to 100 Amp , 25 kA, adjustable O/L & adjustable S/C setting, 71 160 Amp , 25 kA, adjustable O/L & adjustable S/C setting, 72 Providing & Fixing of ding dong/musical chime bell as per PWD specification for electrical Works, including making connection testing etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 73 P&F metal clad / Plastic industrial plug top & socket unit with pin and sleeve type contact on porcelain/ bakelite base in Recessed/surface mounting heavy duty Enclosure made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3. powder painted (without MCB) including making connections, testing etc.as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 74 32 amp, 5 pin + scrapping Earth, 8 Module 75 Providing & Fixing of ISO certified company made on load change over switch, front handle operated, four pole 415 V as per PWD specificationfor electrical Works conforming to IS/lEC 60947-3 : 1999 including connections , testing etc. as required .in the following rating.Appropriate type test certificate / OEM test report shall be submitted .All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 76 Open execution type 77 63 A 78 Supply , Installation, Testing and Comissioning ofInverter type Air Cooled Hi Wall split type Air conditioners with latest star rating system as per BEE amended upto date complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU), R-32/R-410 Green Refrigerant, wireless Remote control, suitable for working between 230V +/- 10% with low & high voltage cutoff and50 hz , single phaseACsupply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 79 1.5 TR ISEER not less then 3.8 80 2.0 TR ISEER not less then 3.8 81 Providing & Fixing of IS : 4985 - 2000 Class -4 (10 Kgf / Sqcm) UPVC drain water piping withfittings (IS:7834 & 10Kgf/sqcm) like elbow, socket, Tee, solvent cement jointing,support with MS hanger on ceiling or recessed in wallwith chasing & plastering with 6 mmthickclosedcellelastomeric nitrile rubberinsulation including leakage testing etc. as required of following Nominal sizes. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 82 25 mm 83 Supply & fixing MS powder coated stand suitable for 1.0/1.5/ 2.0 Tr outdoor type of Split AC.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 84 Making hole in stone masonary/ RCC wall/ RCC slab with core cutter for accomodating refrigerant pipe/ drain pipe/ MS pipe/ cables etc of following dia 85 150 mm dia per running inch length 86 Supply, Fixing and testing of following capacity ISO certified company made wall mounted stabilizer having output voltage variation from 200 V to 250 V(+/-5%) with input voltage variation from 170 V to 260 V, time delay facility from 2 to 4 minute and high cutoff at 270 V with providing of 16 Amp /20 Amp Industrialplug top making connection etc complete in all respect.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 87 4 kVA 88 5 kVA 89 Providing & Fixing of IP-20 LED Recessed / Surface Mounted, Round / SqaureSMD Mid Power LED Downlight with power coated die-cast aluminum housingwith UV Stabilized non yellowish Diffuser withBIS complience 2.5 KV surge protected Isolated driver, with Short & Open circuit protection, having efficiency > 85% . System Lumen efficacy of ≥ 110 lm / watt, THD < 10 % , Pf.≥0.95, CRI >80,life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. 90 OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 91 Surface Mounting (with extruded alumn. Housing ) 92 Minimum lumen output 1950 lm 93 SITC of Monoblock motor pump set ISI marked (IS:9079-2002) with TEFC motor, motor should be IE2 class as per IEC 60034-2-1: 2007, IEC 60034-30: 2008,& IS12615:2011. with Stainless steel Impellor, Stainless steel shaft, Mechanical seal, Single/Three phase ( 240 - 440 V ) permanent split capacitor type (PSC), fitted with thermal overload protection, Including cost of hardware etc on existing platform complete. Pump shall have following HP Rating, phase, Head, minimum Discharge respectively complete in all respect. OEM shall have submitNABL / CPRI / ERDA accrediatedlab type test certificate before execution. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 94 1.0 HP, 1-Ø, (10-120)Mtr, (30-12) LPM 95 Supply & Fixing of Dry Powder Agent (as per IS 4308:2019), ABC typeFire Extinguisher (Stored Pressure type) conforming to IS:15683:2018 , Powder coated Internal & External Surface Deep drawn cylinder body of Mild Steel CR2 grade conforming to IS: 513, Squeeze grip Forged brass release valve with Inbuilt safety release device, Diaphragm Type, 0 to 28 bar range pressure gauge, 450 mm long EPDM discharge tube, QR code for Product Traceability including Fixing on wall with suitable Anchor Fasteners as required of following capacity. Test Certificates of all the Parameters along with Hydro test & Burst test (For Cylinder Body) Certificatefrom OEM / External NABL Accrediated Lab is to be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 96 4 kg 97 Providing & Fixing of Vertical(BEE 5 star rated) / Horizontal( BEE 3 star rated) storage water heater with outer casing made of Engineering Plastic sheet (Upto 25 Ltr) / Metal rust proof Body (35 & 50 Ltr), Glass - line / Titanium Enamel coated Pressure Pump Compatible 8 bar pressure Inner tank, Glass Line Coated , mineral filled heating element, stem type, snap actionadjustable thermostat , Dual indicating lampsInjected PUF insulation, Multi Function Valve etc. as required held in position with 2/4 no. 10/12 mm anchor Fastener, duly wired with 3 core 2.5/4.0 Sqmm PVC insulated & sheathed copper conductor and 16 A/25A three pin plug top with Portable Residual Current Device ( PRCD ) , including making inlet, outlet Flexible alloyconnection, testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 98 15 Ltr. 99 Supplying and drawing PE Insulated & PVC Sheathed unarmoured telephone cable with 0.5 mm dia. Solid Annealed electrolytic grade bare Copper Conductor as per IS: 8130/84 &confirming to TEC specification GR / WIR/06-03 March 2002in existingsurface or recessed conduit/casing capping. including ferruling on each pair for Identification etc. as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 100 2 pair 101 P & F Krone module with base framein the recess / surface made out of 1.2 mm thicksheet steel box, front openable, having locking arrangements duly powder painted,including dressing, ferrulingandpunchingof telephone cable with krone tool etc. as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 102 10 Pairs 103 Providing & Fixing of following modular accessories as per PWD specification for electrical Works,made out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating , includingall as per pre approved by Engineer in charge,making connections, testing etc. as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 104 RJ-11 telephone jack singleline 105 Supply, Drawing and Testing of 4 pair, 23 AWG Solid Bare Copper wire insulated with PVC, UTP (Unshielded Twisted Pair), Category 6, Class E, 100 Ohm Impedance, Indoor Cable as per latest ammendments of ANSI/TIA/EIA-568 , The copper conductors should be balanced twisted in pairs, seperated by a cross-member fluted pair divider & protected byPVC Jacket. Certified performance in a 4-connector configuration upto 100 Mtrs channel requirements & transmission frequencies up to 250 Mhz. in existing MS/PVC Conduits/casing capping including making connections to Information outlets and Patch Panels with jack &ferruling at both ends for identification with necessary tools for punching, stripping, crimping and testing etc as required complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 106 Supply and Installation of unsheilded/360 degree sheilded Information outlets made of high impact plastic body with ABS, FR Grade halogen free material with provision for protection against dust in jack, suitable for Cat 6/6A application complying to latest ammendments, According. to Cat. 6/6A channel, It should support channel as well as components requirements of Cat.6/6A standards at frequencies of up to 250 to 500 Mhz. Cat 6/6A unshielded/shielded Jack should be suitable to terminate 4 pair, 23/24 AWG solid/stranded wire diameters, using 100 Ohm unshielded/shielded balance twisted pair cable, the jack should have tooless/impact termination on reliable copper tin plated Insulation displacement contact, with easy lock mechanism, It supports IEC 60603-7-4 and complied with ANSI/TIA/EIA 568 C.2 standard. jack should be RJ11,RJ12 & RJ45 compatible. Should support Ethernet 1.2 Gb/s ATM,Digital video and broadband/baseband analog video, Voice over internet protocal (VOIP) Specifications in existing modular/MS Boxes along with necessory connections as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 107 Cat 6, Un-sheilded Information Outlet 108 Supply & fixing of square Faceplate for Flush / Surface Mount Information Outlets Single/Dual or Quad Aperture ,material should bePC+ABS body, Suitable for RJ45 unshielded/shielded connection modules. Should match with I. O. OEM. Dimensions should be 86mm X 86mm as required complete in all respect.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 109 Single Aperture 110 Supply & Installation of IP-20 & IK-08 , UL ListedWall mounted Double Section Communication enclosure (Rack) made from powder coated (60 to 80 Micron) CRCA sheet, front sturdy sheet steel frame folded from one piece and welded with minimum 5mm toughened glass door,Vertical Mounting Rail 1.6 MM with UMarking , with All round protective channel on the door aperture, lock integrated on front door, top and bottom cover with cable entry provision with gland plates, integrated side walls, 2 pair of 19 angles with wall mounting provision on wall. Accessories like: 1 No of 19 1U Horizontal Cable manager, 1 No of 90 cfm 230V AC Fan with 1 mts long cable, mounting hardware , 1 No of 19 1U, mountable socket strips with 5 nos of 5A universal sockets with 2 mts long power chord for supplying power to switches, fans etc along with earth continuity kit, indicator, moulded power supply cable. fixing on wall with Suitable Anchor fastneretc as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 111 6 U Rack with Width 600 mm &Depth 400 mm + 100 mm 112 Supply, Installation, Testing and Comissioning of Rack mounted 19 1U, Cat6 24 Port loaded, 1.5-1.6 MM CRS chasis, powder coated, sheet steel, made of plastic (ABS), Modular Patch Panelswith Rear Cable management system and mounting hardware to mount the patch panel. Should have port identification numbers printed/engraved on front of the panel. Etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 113 Modular Patch Panel Loaded with Cat -6 I/O 114 Supply , Installation, Testing and Comissioning ofUnmanaged Switch Plug-and-play - easy setup with no configuration or no software needed, following Port fast ethernet - 8 port 10/100 MBPS auto-negotiation RJ45 ports,IEEE 802.3x flow control ,supports auto-MDI/MDIX, eliminating the need for crossover cables including making connection etc as required complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 115 24 Port 116 Providing & Fixing of IP20, 2x2 LED Surface/ Recessedmounting Mid power SMD type LED Light fixture not less than 50mm housing depth made from CRCA sheet steel housing, high purity / transmisivity UV stabilized Non -yellowish diffuser for uniform light distribution. High efficiency with 4 KV internal/external surge protection BIS certified isolated driver having efficiency > 85% , with Short & Open circuit protection(Integral with light fixture). System lumen efficacy of ≥ 120 lm/Watt ,THD < 10 % , p.f.≥0.95,CRI >80 ,life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. 117 OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted.All as per pre approved by Engineer in charge. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 118 Recessed Mounting 119 Minimum lumen output 4200 lm 120 Supply , Installation and Testing of 4 pair, 100 Ohm impedance, Cat 6/6A /Class E/Ea patch cords should be constructed of minimum 23/24 AWG, stranded bare Copper cable with FRPVC/LSZH Jacket, with an enhanced performance by factory moulded RJ45 connectors with strain relief boots as per ANSI/TIA/EIA 568-C.2 suitable for Cat 6/6A application complying to latest ammendments Category 6/6A Standards, According. to TIA568C.2, ISO/IEC 11801, EN 50173, IEC 60603-7-51, EN 60603-7, IEEE 802.3an minimum requirement for 1G BASE-T to 10G BASE-T performance. Patch cords shall be straight thru cable compatible with both T568-A and T568-B wiring schemes, should support IEEE 802.3af / IEEE 802.3at for POE applications, Minimum 750 to 1000 mating cycles in plug contacts for long durability, Should support Ethernet 10GBASE-T, 1.2 Gb/s ATM, Token ring 4/16, Digital video and broadband/baseband analog video, Voice over internet protocal (VOIP).All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 121 Cat 6, U/UTP (Unscreened/Un-sheilded Twisted Pair) Patch Cord 122 1 Mtr 123 Supplying and making one end termination with Nickel plated heavy duty brass single compression gland (as per IS 12943-1990)) SIBG type consisting of Check Nut, Gland Body, Metal Washer(3 Nos.), Outer Seal Rubber Ring,Compression Nut,heavy duty aluminium lugs (as per IS 8309 -1993) duly crimped with crimping tool, PVC tape as perIS 8337-1976offollowing size ofPVC insulated & PVC sheathed/ XLPE aluminium conductor cable of 1100 volt grade as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 124 3.5 x 25.0 sq.mm 125 Supply, installation, testing and comissioning ofinterconnectingcopperrefrigerant pipingof DHE Grade C12200- ASTM B68, B75, chemical composition of copper %- 99.0 Min and Phosphorus %- 0.015 to 0.040 . For Annealed copper tube :- Tensile strength = 210 Mpa wih elongation % = 40 Min . Ink MarkBrand Printing on Hard Tubes should be present. duly insulated with tubular elastomeric nitrile rubber FM/UL approved with high water vapor diffusion resistance and low thermal conductivity should be certified Class O in Fire Propagationas per BS 476 Part 6 including chase cutting andfilling with mortar, Slotted channel supports mounted on 10 mm threaded rod at suitable spacing the exposed piping shall be wrapped with glass woven cloth and lag coating for vapour barrier and weather protection. Joints shall be covered with nitrile rubber tape of 3 mm thick complete as required of following sizes. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 126 12.7 mm O.D., wall thinkness ≥ 0.8mm (insulation – 13 mm thick) 127 6.4 mm O.D., wall thinkness ≥ 0.8mm (insulation – 13 mm thick) 128 Supply , Installation, Testing and Comissioning of IS:1475 marked self contained drinking water cooler withhermeticallysealed compressor,non CFC refrigerent suitable for operation on 230V/1pH/50Hz AC supply,Full stainless steel (SS304)body (0.8 mm thick)and tank (0.5 mm thick) , stainless steel water tray,minimum two nosBrass Chrome plated faucets and suitable drainage system complete in all respect with requiredheight MS fabricated and Painted Angle iron frame( Cost of frame to be paid Extra )complete in all respect of the following capacity.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 129 cooling capacity 150 Ltr./Hr. and storage capacity 150 Ltrs 130 Providing and fixing welded mesh/expanded metal mesh 25 mmx 25 mm x 3mm in frame work, flat iron beading 20x3mm including top cross laps inside and out sides welding, iron bolts, crews, clips etc. including two coat of red oxide and two coat of enamel paint or more requiredcomplete with frame work with 50 X 50 X 6mm angle iron post 30 cm in ground embeded in cement concrete 1:3:6 (30X30X45cm) at corner and every three mtr including painting with one coat of primer and two coat of enamel paint work will be done as per direction of engineer incharge of sizecomplete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 131 SITC of IP-42 and general construction confirming to IS:8623 : 1993, wall/ free standing floor mounted dust and vermin proof compartmentalisedcubical panel as specifications andOther parameters requiredas per point (a) ,(b), (c),(d), (e), (f), (g), (h) as below:- 132 (a)Thickness of CRCA sheet shallbe 2.0 mm,cable alley compartments having concealed hinged type doors with key type lock with / withoutdetachable extension type structure. Removable 3 mm. thick sheet steel gland plates with appropriate size of knockouts for cables shall be provided 133 (b)complete panel shall undergo a process of degreasing, Water rinsing, Activation, derusting,pickling in acid bath, phosphatising & shall be subjected to nine tank process and then Powder coated with approved shade of minimum 70 microns on both side of panel.The panel having PE foam/ Neoprene rubber gasket of not less than 3mm thickness ,required hardware , concealed hinged door with key type locking arrangement for equipment/switchgear earthed with 2.5 sq.mm braided copper wire. 134 [c)Interconnection between bus bar and switchgears /cable shall be rigidly supported and made out by flexible copper wires (up to 63 amp ) and by solid bus bar(>63 amp ) . control wiring will be carried out with 1.5 Sq.mm, Earth wire with 2.5 Sq.mm and CT with 2.5 sq.mm flexible copper wire only.All joints / interconnections of copper bus bar shall be dully tinned . Clearance between main bus bar and risers / metal parts shall be at least 10 mm additional to width of bus bar Bus bar is insulated by Heat Shrinkable sleeves . Earth and Neutral bus bar shall be half of the size of phase bus bar. ( Cost of Bus bar/ Flexible wire for Interconnection between Main busbar and Switchgearis to be Paid Extra ) 135 (d)Wiring between components within switchgear and Incoming / outgoing cableshall be done through the terminal block only. Direct connection shall not be permitted. Each terminal block shall be one piece moulded, barrier type, 650 volt grade, complete with washers, heads, studs with two nuts and identification strips and shall have adequate continuous current rating. For tap-offs, adjacent terminals with shorting strips shall be used. 10% Spare terminal blocks shall be provided. Wire identification on marking strip shall correspond to the designation of the wiring diagrams. All wire terminals on the equipment shall also be marked with designation corresponding to those of the wiring diagram. 136 (e)All wiring shall be enclosed in plastic channels and neatly bunched and closed in metering chamber, Wiring between terminals of various devices shall be ‘point to point’ (no wire splitting or tee connections) with wires neatly trucked along the back of the panels, adequately supported to prevent sagging. 137 (f)Floor mounted panel shall be mounted on Base frame of ISMCchannel size 100 x 50 x 5 mm( to be paid Extra ) 138 (g) Tests: The insulation resistance (with 1000 V Megger) and High voltage Power frequency test (by applying a voltage of 2.5KV for one minute) shall be measured between phases, between phase and neutral and between phase and earth. both before and after high voltage power frequency test. The insulation resistance shall not be less than three megaohm. CT Secondary current injection test shall also be carried out. 139 (h) only outer surface area on all sides shall be measured & panel to be fabricated only from CPRI approved fabricator only (CPRI Test certificates to be submitted)All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 140 Providing & Fixing of BIS approvedCurrent Transformeras per PWD specification for electrical Works ,ISI marked as perIS 2705-1992/ conforming to IEC 60044-1, with secondary terminalof CT shall be brought out suitable to a terminal block which shall be easier accessible for testing and terminal connection , with all necessary support in existing panel including connection etc. as requiredCurrent transformer Ring Type Tape Wound/Resin Cast Wound as per IS 16227 with, Accuracy Cl, CT ratio and burden as specified. ISF<=5, Cu cross section of secondary wire 1.5sqmm (minimum), including all necessary support in existing panel including connection etc. as required . All as per pre approved by Engineer in charge.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 141 Ring type tape wound CT 142 C T Class 1, Ratio 200/5 to 300/5, Burden 10 VA 143 Providing & Fixing of110/220 V, unibody LED Indicatinglamp IEC 60947with integral circuit, IP 65 above panel &IP 20 terminal block, Approx. body dia for panel not less then 20 mm, length min. 50mm, front LED cover dia min.29 mm, contact material phospher bronze for Led, PCB contacts shall be ofbrass (tin plated), impulsedielectric tested for 2.5 KV, Rated insulation resistance shall be 100 M ohm at 500VDCincluding connection etc. as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 144 Red/yellow/Green colour 145 Supplying and fixing of Aluminium (IEC 60105 ISO 209-1,2) / Copper (IEC 60028) bus bar by means of SMC / DMC type insulatorwith standard short circuit withstand capacity, high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable PVC sleeves. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 146 Electrolytic grade Aluminium bus bar 6010 grade 147 Providing & Fixing of 240/415 V factory fitted RCBO with overload, short-circuit and earth leakage protectionwith ISI marked (IS12640-2)/ conforming to IEC 61009-1, breaking capacity 10 KA,provision for pad lock, min. Electrical operation 10,000 upto 63 A rating , minimum phase termination capacity of 35sq.mm. , IP 20 contact protection with existing distribution board / sheetincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 148 Two pole 100/300mA sensitivity 149 40 A rating
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
16.
Health and Family Welfare #10551411 Price Bid
Tender For Electrification Work In Phc Building At Rajlani District Jodhpur - 1 (Electrical BSR 2022 Rajasthan) Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)inrecessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit & itsISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thickHot Dipped Galvanized Modular Box with earth terminal, 10A Modular switch,Modular face plate with grid plate, 3 pin ceiling rose / Holder /3 way connector, screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR. Short point (up to 3 mtr.) 2 Short point (up to 3 mtr.) 3 Medium point (up to 6 mtr.) 4 Long point(up to 10 mtr.) 5 Wiring of twin control light point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)in recessed ISI markedMMS ( IS:9537 P - III ) PVC conduit & its ISI marked (IS:3419-1988) accessories, round tiles, 2 Nos Hot Dipped Galvanized M.S Modularbox of 1.2 mm thickwith earth terminal,2 Nos10 A two way Modular switch, 3 pin ceiling rose / holder / 3 way connector ,Modular face plate with grid plate,screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR 6 Medium point (up to 6 mtr.) 7 Long point(up to 10 mtr.) 8 Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal sizeFR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) inrecessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & its ISI marked (IS:3419-1988)accessories, Hot Dipped GalvanizedModular box of 1.2 mm thick with earth terminal, 10 A modularswitch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR 9 On board 10 Supplying and fixing of power plug point with Modular accessories as per PWD specification for electrical Works, on hot dipped galvanized modular box of 1.2 mm thick with earthing terminal/connector on surface or in recessed with suitable size of modular face place with grid plate and cover plate including cost ofISI marked modular 16 amp. Switch (IS :3854) and 6/16 amp. socket outlet (IS:1293) making connection , testing , etc. as required. For specification ofWiring accessories refer ChapterE - 07related item & For additional technical parameters of product / work refer Annexure A attached with this BSR 11 Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 forlower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5,in existingsurface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure A attached with this BSR 12 3x 1.5 sq.mm 13 2 x 2.5 sq. mm. + 1x1.5sqmm 14 2 x 4.0 sq. mm. + 1 x 2.5 sq. mm. 15 4 x 10.0 sq.mm 16 4 x 6.0 sq.mm 17 1 x 2.5 sq.mm 18 Providing & Fixing of Recessed/surface mounting heavy duty horizontal type Double Door ( Metal / Glazed )Distribution board with Metal end box made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3, powder painted complete with reversible door (for double door DB only )100 amp. insulated copper bus bar/shorting link , copper neutral link, copper earth link , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, Ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 19 Metal door (Three phase) Per phase isolation, Horizontal IK-09 and IP-43 with Metal end box 20 6Way(Incomer 8,Sub Incomer2+2+2) 21 Metal door (single phase) IK-09 and IP-43 with Metal end box 22 16 Way (16+2) 23 Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load andsite requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting ofclass 3 as per IEC,minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted inexisting distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above ratingincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 24 Single pole MCB (With B/C curve tripping Characteristics) 25 6 A to 32 A rating 26 Four pole MCB (With B/C curve tripping Characteristics) 27 40 A rating 28 Double pole MCB(With B/C curve tripping Characteristics) 29 6 A to 32 A rating 30 S&F following sizes (dia.) of ISI marked virgin material MMS ( IS:9537 P - III ) PVC conduit along withISI marked (IS:3419-1988) accessories as requiredinrecessincludingcutting the wall, covering conduit and making good the same as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 31 20 mm 32 25 mm 33 P & F phenolic laminated sheet 2.0 mm thick of following size . Including screws, cup washer as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 34 75 mm dia 35 Providing & Fixing of modular type 120 W Step Fan regulator duly ISI marked (IS 11037:1984 ) with CM/L no. printedmade out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating ,includingall as per pre approved by Engineer in charge,making connections, testing etc. as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 36 5 step fan regulator 2 Module 360 dgree rotating 37 P & F 1.2mm thickM.S. Recessed fan box, hexagonal/ round of size 130 mm dia, depth 75mm,12 mm dia rod fan hook with 100 mmlength extended on each side . All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure A attached with this BSR 38 Providing & Fixing of Heavy duty capacitor start, copper woundDouble ball bearing900/1400 RPM single phaseExhaustfan conforming to IS:2312 ISI marked in existing opening including making connections testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 39 300 mm sweep(900/1400 RPM) 40 Providing & Fixing of IP20 SMD Mid Power LED batten type integrated light fixture made from Powder coated Extruded aluminiumhousing with in built driver, System lumen efficacy ≥ 110 lm/Watt output, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, CRI >80 , life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , Maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 41 1170mm(+/-10%) LED batten with min. lumen output 2200 lm 42 Providing & Fixing ofBEEStar rated copper wounded double ball bearing capacitor start, aluminium body & Metallicblade ceilingfanConforming to all the performance requirements laid down in IS 374:2019 including all amendments, as applicable ; & Carry BIS licensing (i.e. ISI marking) with down rod up to 80 cm with secondary support safety cable ( steel rope) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 43 1200 mm Sweep BEE 1 Star rated (service value >=4.0 to < 4.5 ) 44 Providing & Fixing ofof Double ball bearing, copper wounded capacitor startsingle phase metallicblade fresh air fan, in existing opening including cost of hardware , flexible 3 core copper conductor ,making connections, testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 45 225 mm sweep 46 Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed ArrmouredAluminiumcable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV withH4- Grade electrolyticaluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) includingtesting etc. as required of following size. OEM must have its own in house NABL accrediated Laboratory for testing procedure as per IS:10810.For additional technical parameters of product / work refer Annexure A attached with this BSR 47 25.0 Sq. mm 48 3.5 core 49 6.0 Sq. mm 50 2 core 51 Add Extra for Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV gradedirect in ground including excavation of trench of size 75 cm (Depth) x 35 cm(Width) ,with procedure as per followingpoints:- (a) Make a river sand bed of height 125 mm along the trench,(b) Lay the cable in the middle of the trench,(c) Provide river sand bed of height 125 mm on top of the cable, (d) Lay the protective Common burnt clay F.P.S. Bricks of Class designation 75 / Sand stone slabs of 50 mm thicknessand 225 mm widejust above the sand bed vertically across the cable ( Approx. 9 no. Bricks per Mtr.), (e) Backfill the excavated soil leaving 300 mm from the Ground level, (f)Lay the Cable warning tape and again back-fill the remaining portion of the trench upto the ground level and compacting the earth 52 Add Extra in item no. 11.1 to 11.4 for Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. 53 Up to 35 Sq.mm fixed with 25 mm x 2 mm thick suitable length red oxide and enamel painted MS clamp and base, pvc rawl plug and screws of sufficient size with spacing 0.6 Mtr. Between Clamps. 54 Supplyandinstallationofhigh tensile low carbon steel rod molecularly bonded with 99.9 % Copperthickness (250 microns) andconfirming toUL 467, IS/IEC 62561-2of following size and length and as per point mentioned (a), (b), [c), (d), (e) below :- 55 (a) Bore a hole of dia. 100 mm of required length, Place the rod in the centre of Hole 56 (b)filled with anti corrosiveconductivecompounds with the permanent sealings at both the ends, CPRI/ ERDAtested with RMS capacity of minimum 30 KA for withstanding 1 second .To ensure the moisture content and electrical conductivity, 25 kg for 2000 mm & 50 Kgs for 3000mm of resistance lowering earth enhancement material shall be used as a backfill compound. The compound shall be tested form NABL acredeated labfor lowresistivity ( less than 0.12 Ohm - meter ) & high conductivity in nature with carbon as a major contentas per referance of IS 3043-1987,IEEE 80-2013 (clause 14.5d) , IEEE 837 & IER 1956 with latest amendemnts 57 © Connect the rod with copper Strip/Conductor/Wire with suitable clamp made from tinned copper and SS 304 Bolt 58 (d) Place Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height250 to 300 mm. 59 (d)Testing of earth resistance for value of 5 ohms or lessas required & must record by engineer in charge during site visit and ensure to enter in measurment book. 60 (e) Test certificatesfor confirming above standards from OEM is mandatory. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 61 17.2 mm thick and 3 Mtr. Long 62 Supply & Laying following size earth wire in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles,making connection with GI/Cu purity purity >95%thimble etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 63 8 SWG G.I. ( Hot Dipped) Wire 64 Providing & Fixing of IK08, IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminummaterial with heat dissipation fins on housing with UV stabilized PC (UV stablization report submitted for UV cover ) /Toughened Glass coverand secondary lens on each LED & should be SMD type of 3 to 5 watt each . The System efficacy >=125 lm/ wt and potted driver& has a unique BIS R number withInput Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety , Power Factor >0.95 driverEfficiency >85%,THD(I) <10%Humidity 10% to 90% RH Working Temp -5C to 45C .driver current <750mA. The luminaireshall be BIS certified and Trade mark certified. Life ExpectancyEqual or more than 50000 burning hrs with Minimum 70% lumen maintened , CRI >70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external inside driver compartment. driver should be Phase to phase protection of 440 V for 4 Hrs.Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities forLED fixtures.(LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 65 LED Street Light fixture with Minimum lumen output 2450 lm 66 Providing & Fixing of Street light bracket made out from following size of B class , Medium class G.I. Pipe confirming to IS : 1239 P - 1 ( 2004 ) with heavy duty pole clamp, Saddles suitable fastners etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 67 25 mm Dia. 68 SITC of3 /4pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant materialhaving following current rating, short circuitbreaking capacityat 440/415 V, 50 Hz; O/L & S/C settings , conforming to IS/IEC 60947 P -2 :2003 with frontface and centralised adjustable, trip free mechanisum, true contact position indicator,line load interchangeability,designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree,pollution degree 3, having positive isolation capability, push(test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% Icu. U imp =8 KV, rated insulation voltage690 V.provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connectionsetc. as required.OEM shall have submitNABL / CPRI / ERDA accrediated lab type test certificate before execution All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 69 4 pole MCCB With Thermal Magnetic release 70 up to 100 Amp , 25 kA, adjustable O/L & adjustable S/C setting, 71 160 Amp , 25 kA, adjustable O/L & adjustable S/C setting, 72 Providing & Fixing of ding dong/musical chime bell as per PWD specification for electrical Works, including making connection testing etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 73 P&F metal clad / Plastic industrial plug top & socket unit with pin and sleeve type contact on porcelain/ bakelite base in Recessed/surface mounting heavy duty Enclosure made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3. powder painted (without MCB) including making connections, testing etc.as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 74 32 amp, 5 pin + scrapping Earth, 8 Module 75 Providing & Fixing of ISO certified company made on load change over switch, front handle operated, four pole 415 V as per PWD specificationfor electrical Works conforming to IS/lEC 60947-3 : 1999 including connections , testing etc. as required .in the following rating.Appropriate type test certificate / OEM test report shall be submitted .All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 76 Open execution type 77 63 A 78 Supply , Installation, Testing and Comissioning ofInverter type Air Cooled Hi Wall split type Air conditioners with latest star rating system as per BEE amended upto date complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU), R-32/R-410 Green Refrigerant, wireless Remote control, suitable for working between 230V +/- 10% with low & high voltage cutoff and50 hz , single phaseACsupply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 79 1.5 TR ISEER not less then 3.8 80 2.0 TR ISEER not less then 3.8 81 Providing & Fixing of IS : 4985 - 2000 Class -4 (10 Kgf / Sqcm) UPVC drain water piping withfittings (IS:7834 & 10Kgf/sqcm) like elbow, socket, Tee, solvent cement jointing,support with MS hanger on ceiling or recessed in wallwith chasing & plastering with 6 mmthickclosedcellelastomeric nitrile rubberinsulation including leakage testing etc. as required of following Nominal sizes. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 82 25 mm 83 Supply & fixing MS powder coated stand suitable for 1.0/1.5/ 2.0 Tr outdoor type of Split AC.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 84 Making hole in stone masonary/ RCC wall/ RCC slab with core cutter for accomodating refrigerant pipe/ drain pipe/ MS pipe/ cables etc of following dia 85 150 mm dia per running inch length 86 Supply, Fixing and testing of following capacity ISO certified company made wall mounted stabilizer having output voltage variation from 200 V to 250 V(+/-5%) with input voltage variation from 170 V to 260 V, time delay facility from 2 to 4 minute and high cutoff at 270 V with providing of 16 Amp /20 Amp Industrialplug top making connection etc complete in all respect.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 87 4 kVA 88 5 kVA 89 Providing & Fixing of IP-20 LED Recessed / Surface Mounted, Round / SqaureSMD Mid Power LED Downlight with power coated die-cast aluminum housingwith UV Stabilized non yellowish Diffuser withBIS complience 2.5 KV surge protected Isolated driver, with Short & Open circuit protection, having efficiency > 85% . System Lumen efficacy of ≥ 110 lm / watt, THD < 10 % , Pf.≥0.95, CRI >80,life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. 90 OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 91 Surface Mounting (with extruded alumn. Housing ) 92 Minimum lumen output 1950 lm 93 SITC of Monoblock motor pump set ISI marked (IS:9079-2002) with TEFC motor, motor should be IE2 class as per IEC 60034-2-1: 2007, IEC 60034-30: 2008,& IS12615:2011. with Stainless steel Impellor, Stainless steel shaft, Mechanical seal, Single/Three phase ( 240 - 440 V ) permanent split capacitor type (PSC), fitted with thermal overload protection, Including cost of hardware etc on existing platform complete. Pump shall have following HP Rating, phase, Head, minimum Discharge respectively complete in all respect. OEM shall have submitNABL / CPRI / ERDA accrediatedlab type test certificate before execution. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 94 1.0 HP, 1-Ø, (10-120)Mtr, (30-12) LPM 95 Supply & Fixing of Dry Powder Agent (as per IS 4308:2019), ABC typeFire Extinguisher (Stored Pressure type) conforming to IS:15683:2018 , Powder coated Internal & External Surface Deep drawn cylinder body of Mild Steel CR2 grade conforming to IS: 513, Squeeze grip Forged brass release valve with Inbuilt safety release device, Diaphragm Type, 0 to 28 bar range pressure gauge, 450 mm long EPDM discharge tube, QR code for Product Traceability including Fixing on wall with suitable Anchor Fasteners as required of following capacity. Test Certificates of all the Parameters along with Hydro test & Burst test (For Cylinder Body) Certificatefrom OEM / External NABL Accrediated Lab is to be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 96 4 kg 97 Providing & Fixing of Vertical(BEE 5 star rated) / Horizontal( BEE 3 star rated) storage water heater with outer casing made of Engineering Plastic sheet (Upto 25 Ltr) / Metal rust proof Body (35 & 50 Ltr), Glass - line / Titanium Enamel coated Pressure Pump Compatible 8 bar pressure Inner tank, Glass Line Coated , mineral filled heating element, stem type, snap actionadjustable thermostat , Dual indicating lampsInjected PUF insulation, Multi Function Valve etc. as required held in position with 2/4 no. 10/12 mm anchor Fastener, duly wired with 3 core 2.5/4.0 Sqmm PVC insulated & sheathed copper conductor and 16 A/25A three pin plug top with Portable Residual Current Device ( PRCD ) , including making inlet, outlet Flexible alloyconnection, testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 98 15 Ltr. 99 Supplying and drawing PE Insulated & PVC Sheathed unarmoured telephone cable with 0.5 mm dia. Solid Annealed electrolytic grade bare Copper Conductor as per IS: 8130/84 &confirming to TEC specification GR / WIR/06-03 March 2002in existingsurface or recessed conduit/casing capping. including ferruling on each pair for Identification etc. as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 100 2 pair 101 P & F Krone module with base framein the recess / surface made out of 1.2 mm thicksheet steel box, front openable, having locking arrangements duly powder painted,including dressing, ferrulingandpunchingof telephone cable with krone tool etc. as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 102 10 Pairs 103 Providing & Fixing of following modular accessories as per PWD specification for electrical Works,made out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating , includingall as per pre approved by Engineer in charge,making connections, testing etc. as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 104 RJ-11 telephone jack singleline 105 Supply, Drawing and Testing of 4 pair, 23 AWG Solid Bare Copper wire insulated with PVC, UTP (Unshielded Twisted Pair), Category 6, Class E, 100 Ohm Impedance, Indoor Cable as per latest ammendments of ANSI/TIA/EIA-568 , The copper conductors should be balanced twisted in pairs, seperated by a cross-member fluted pair divider & protected byPVC Jacket. Certified performance in a 4-connector configuration upto 100 Mtrs channel requirements & transmission frequencies up to 250 Mhz. in existing MS/PVC Conduits/casing capping including making connections to Information outlets and Patch Panels with jack &ferruling at both ends for identification with necessary tools for punching, stripping, crimping and testing etc as required complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 106 Supply and Installation of unsheilded/360 degree sheilded Information outlets made of high impact plastic body with ABS, FR Grade halogen free material with provision for protection against dust in jack, suitable for Cat 6/6A application complying to latest ammendments, According. to Cat. 6/6A channel, It should support channel as well as components requirements of Cat.6/6A standards at frequencies of up to 250 to 500 Mhz. Cat 6/6A unshielded/shielded Jack should be suitable to terminate 4 pair, 23/24 AWG solid/stranded wire diameters, using 100 Ohm unshielded/shielded balance twisted pair cable, the jack should have tooless/impact termination on reliable copper tin plated Insulation displacement contact, with easy lock mechanism, It supports IEC 60603-7-4 and complied with ANSI/TIA/EIA 568 C.2 standard. jack should be RJ11,RJ12 & RJ45 compatible. Should support Ethernet 1.2 Gb/s ATM,Digital video and broadband/baseband analog video, Voice over internet protocal (VOIP) Specifications in existing modular/MS Boxes along with necessory connections as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 107 Cat 6, Un-sheilded Information Outlet 108 Supply & fixing of square Faceplate for Flush / Surface Mount Information Outlets Single/Dual or Quad Aperture ,material should bePC+ABS body, Suitable for RJ45 unshielded/shielded connection modules. Should match with I. O. OEM. Dimensions should be 86mm X 86mm as required complete in all respect.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 109 Single Aperture 110 Supply & Installation of IP-20 & IK-08 , UL ListedWall mounted Double Section Communication enclosure (Rack) made from powder coated (60 to 80 Micron) CRCA sheet, front sturdy sheet steel frame folded from one piece and welded with minimum 5mm toughened glass door,Vertical Mounting Rail 1.6 MM with UMarking , with All round protective channel on the door aperture, lock integrated on front door, top and bottom cover with cable entry provision with gland plates, integrated side walls, 2 pair of 19 angles with wall mounting provision on wall. Accessories like: 1 No of 19 1U Horizontal Cable manager, 1 No of 90 cfm 230V AC Fan with 1 mts long cable, mounting hardware , 1 No of 19 1U, mountable socket strips with 5 nos of 5A universal sockets with 2 mts long power chord for supplying power to switches, fans etc along with earth continuity kit, indicator, moulded power supply cable. fixing on wall with Suitable Anchor fastneretc as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 111 6 U Rack with Width 600 mm &Depth 400 mm + 100 mm 112 Supply, Installation, Testing and Comissioning of Rack mounted 19 1U, Cat6 24 Port loaded, 1.5-1.6 MM CRS chasis, powder coated, sheet steel, made of plastic (ABS), Modular Patch Panelswith Rear Cable management system and mounting hardware to mount the patch panel. Should have port identification numbers printed/engraved on front of the panel. Etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 113 Modular Patch Panel Loaded with Cat -6 I/O 114 Supply , Installation, Testing and Comissioning ofUnmanaged Switch Plug-and-play - easy setup with no configuration or no software needed, following Port fast ethernet - 8 port 10/100 MBPS auto-negotiation RJ45 ports,IEEE 802.3x flow control ,supports auto-MDI/MDIX, eliminating the need for crossover cables including making connection etc as required complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 115 24 Port 116 Providing & Fixing of IP20, 2x2 LED Surface/ Recessedmounting Mid power SMD type LED Light fixture not less than 50mm housing depth made from CRCA sheet steel housing, high purity / transmisivity UV stabilized Non -yellowish diffuser for uniform light distribution. High efficiency with 4 KV internal/external surge protection BIS certified isolated driver having efficiency > 85% , with Short & Open circuit protection(Integral with light fixture). System lumen efficacy of ≥ 120 lm/Watt ,THD < 10 % , p.f.≥0.95,CRI >80 ,life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. 117 OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted.All as per pre approved by Engineer in charge. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 118 Recessed Mounting 119 Minimum lumen output 4200 lm 120 Supply , Installation and Testing of 4 pair, 100 Ohm impedance, Cat 6/6A /Class E/Ea patch cords should be constructed of minimum 23/24 AWG, stranded bare Copper cable with FRPVC/LSZH Jacket, with an enhanced performance by factory moulded RJ45 connectors with strain relief boots as per ANSI/TIA/EIA 568-C.2 suitable for Cat 6/6A application complying to latest ammendments Category 6/6A Standards, According. to TIA568C.2, ISO/IEC 11801, EN 50173, IEC 60603-7-51, EN 60603-7, IEEE 802.3an minimum requirement for 1G BASE-T to 10G BASE-T performance. Patch cords shall be straight thru cable compatible with both T568-A and T568-B wiring schemes, should support IEEE 802.3af / IEEE 802.3at for POE applications, Minimum 750 to 1000 mating cycles in plug contacts for long durability, Should support Ethernet 10GBASE-T, 1.2 Gb/s ATM, Token ring 4/16, Digital video and broadband/baseband analog video, Voice over internet protocal (VOIP).All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 121 Cat 6, U/UTP (Unscreened/Un-sheilded Twisted Pair) Patch Cord 122 1 Mtr 123 Supplying and making one end termination with Nickel plated heavy duty brass single compression gland (as per IS 12943-1990)) SIBG type consisting of Check Nut, Gland Body, Metal Washer(3 Nos.), Outer Seal Rubber Ring,Compression Nut,heavy duty aluminium lugs (as per IS 8309 -1993) duly crimped with crimping tool, PVC tape as perIS 8337-1976offollowing size ofPVC insulated & PVC sheathed/ XLPE aluminium conductor cable of 1100 volt grade as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 124 3.5 x 25.0 sq.mm 125 Supply, installation, testing and comissioning ofinterconnectingcopperrefrigerant pipingof DHE Grade C12200- ASTM B68, B75, chemical composition of copper %- 99.0 Min and Phosphorus %- 0.015 to 0.040 . For Annealed copper tube :- Tensile strength = 210 Mpa wih elongation % = 40 Min . Ink MarkBrand Printing on Hard Tubes should be present. duly insulated with tubular elastomeric nitrile rubber FM/UL approved with high water vapor diffusion resistance and low thermal conductivity should be certified Class O in Fire Propagationas per BS 476 Part 6 including chase cutting andfilling with mortar, Slotted channel supports mounted on 10 mm threaded rod at suitable spacing the exposed piping shall be wrapped with glass woven cloth and lag coating for vapour barrier and weather protection. Joints shall be covered with nitrile rubber tape of 3 mm thick complete as required of following sizes. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 126 12.7 mm O.D., wall thinkness ≥ 0.8mm (insulation – 13 mm thick) 127 6.4 mm O.D., wall thinkness ≥ 0.8mm (insulation – 13 mm thick) 128 Supply , Installation, Testing and Comissioning of IS:1475 marked self contained drinking water cooler withhermeticallysealed compressor,non CFC refrigerent suitable for operation on 230V/1pH/50Hz AC supply,Full stainless steel (SS304)body (0.8 mm thick)and tank (0.5 mm thick) , stainless steel water tray,minimum two nosBrass Chrome plated faucets and suitable drainage system complete in all respect with requiredheight MS fabricated and Painted Angle iron frame( Cost of frame to be paid Extra )complete in all respect of the following capacity.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 129 cooling capacity 150 Ltr./Hr. and storage capacity 150 Ltrs 130 Providing and fixing welded mesh/expanded metal mesh 25 mmx 25 mm x 3mm in frame work, flat iron beading 20x3mm including top cross laps inside and out sides welding, iron bolts, crews, clips etc. including two coat of red oxide and two coat of enamel paint or more requiredcomplete with frame work with 50 X 50 X 6mm angle iron post 30 cm in ground embeded in cement concrete 1:3:6 (30X30X45cm) at corner and every three mtr including painting with one coat of primer and two coat of enamel paint work will be done as per direction of engineer incharge of sizecomplete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 131 SITC of IP-42 and general construction confirming to IS:8623 : 1993, wall/ free standing floor mounted dust and vermin proof compartmentalisedcubical panel as specifications andOther parameters requiredas per point (a) ,(b), (c),(d), (e), (f), (g), (h) as below:- 132 (a)Thickness of CRCA sheet shallbe 2.0 mm,cable alley compartments having concealed hinged type doors with key type lock with / withoutdetachable extension type structure. Removable 3 mm. thick sheet steel gland plates with appropriate size of knockouts for cables shall be provided 133 (b)complete panel shall undergo a process of degreasing, Water rinsing, Activation, derusting,pickling in acid bath, phosphatising & shall be subjected to nine tank process and then Powder coated with approved shade of minimum 70 microns on both side of panel.The panel having PE foam/ Neoprene rubber gasket of not less than 3mm thickness ,required hardware , concealed hinged door with key type locking arrangement for equipment/switchgear earthed with 2.5 sq.mm braided copper wire. 134 [c)Interconnection between bus bar and switchgears /cable shall be rigidly supported and made out by flexible copper wires (up to 63 amp ) and by solid bus bar(>63 amp ) . control wiring will be carried out with 1.5 Sq.mm, Earth wire with 2.5 Sq.mm and CT with 2.5 sq.mm flexible copper wire only.All joints / interconnections of copper bus bar shall be dully tinned . Clearance between main bus bar and risers / metal parts shall be at least 10 mm additional to width of bus bar Bus bar is insulated by Heat Shrinkable sleeves . Earth and Neutral bus bar shall be half of the size of phase bus bar. ( Cost of Bus bar/ Flexible wire for Interconnection between Main busbar and Switchgearis to be Paid Extra ) 135 (d)Wiring between components within switchgear and Incoming / outgoing cableshall be done through the terminal block only. Direct connection shall not be permitted. Each terminal block shall be one piece moulded, barrier type, 650 volt grade, complete with washers, heads, studs with two nuts and identification strips and shall have adequate continuous current rating. For tap-offs, adjacent terminals with shorting strips shall be used. 10% Spare terminal blocks shall be provided. Wire identification on marking strip shall correspond to the designation of the wiring diagrams. All wire terminals on the equipment shall also be marked with designation corresponding to those of the wiring diagram. 136 (e)All wiring shall be enclosed in plastic channels and neatly bunched and closed in metering chamber, Wiring between terminals of various devices shall be ‘point to point’ (no wire splitting or tee connections) with wires neatly trucked along the back of the panels, adequately supported to prevent sagging. 137 (f)Floor mounted panel shall be mounted on Base frame of ISMCchannel size 100 x 50 x 5 mm( to be paid Extra ) 138 (g) Tests: The insulation resistance (with 1000 V Megger) and High voltage Power frequency test (by applying a voltage of 2.5KV for one minute) shall be measured between phases, between phase and neutral and between phase and earth. both before and after high voltage power frequency test. The insulation resistance shall not be less than three megaohm. CT Secondary current injection test shall also be carried out. 139 (h) only outer surface area on all sides shall be measured & panel to be fabricated only from CPRI approved fabricator only (CPRI Test certificates to be submitted)All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 140 Providing & Fixing of BIS approvedCurrent Transformeras per PWD specification for electrical Works ,ISI marked as perIS 2705-1992/ conforming to IEC 60044-1, with secondary terminalof CT shall be brought out suitable to a terminal block which shall be easier accessible for testing and terminal connection , with all necessary support in existing panel including connection etc. as requiredCurrent transformer Ring Type Tape Wound/Resin Cast Wound as per IS 16227 with, Accuracy Cl, CT ratio and burden as specified. ISF<=5, Cu cross section of secondary wire 1.5sqmm (minimum), including all necessary support in existing panel including connection etc. as required . All as per pre approved by Engineer in charge.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 141 Ring type tape wound CT 142 C T Class 1, Ratio 200/5 to 300/5, Burden 10 VA 143 Providing & Fixing of110/220 V, unibody LED Indicatinglamp IEC 60947with integral circuit, IP 65 above panel &IP 20 terminal block, Approx. body dia for panel not less then 20 mm, length min. 50mm, front LED cover dia min.29 mm, contact material phospher bronze for Led, PCB contacts shall be ofbrass (tin plated), impulsedielectric tested for 2.5 KV, Rated insulation resistance shall be 100 M ohm at 500VDCincluding connection etc. as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 144 Red/yellow/Green colour 145 Supplying and fixing of Aluminium (IEC 60105 ISO 209-1,2) / Copper (IEC 60028) bus bar by means of SMC / DMC type insulatorwith standard short circuit withstand capacity, high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable PVC sleeves. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 146 Electrolytic grade Aluminium bus bar 6010 grade 147 Providing & Fixing of 240/415 V factory fitted RCBO with overload, short-circuit and earth leakage protectionwith ISI marked (IS12640-2)/ conforming to IEC 61009-1, breaking capacity 10 KA,provision for pad lock, min. Electrical operation 10,000 upto 63 A rating , minimum phase termination capacity of 35sq.mm. , IP 20 contact protection with existing distribution board / sheetincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 148 Two pole 100/300mA sensitivity 149 40 A rating
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
17.
Health and Family Welfare #10551402 Price Bid
Tender For Electrification Work In Bphu And Bphl At Chc Setrawa Block Dechu District Phalodi - 1 (Electrical BSR 2022 Rajasthan) Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)inrecessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit & itsISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thickHot Dipped Galvanized Modular Box with earth terminal, 10A Modular switch,Modular face plate with grid plate, 3 pin ceiling rose / Holder /3 way connector, screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR. Short point (up to 3 mtr.) 2 Short point (up to 3 mtr.) 3 Medium point (up to 6 mtr.) 4 Long point(up to 10 mtr.) 5 Wiring of twin control light point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)in recessed ISI markedMMS ( IS:9537 P - III ) PVC conduit & its ISI marked (IS:3419-1988) accessories, round tiles, 2 Nos Hot Dipped Galvanized M.S Modularbox of 1.2 mm thickwith earth terminal,2 Nos10 A two way Modular switch, 3 pin ceiling rose / holder / 3 way connector ,Modular face plate with grid plate,screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR 6 Medium point (up to 6 mtr.) 7 Long point(up to 10 mtr.) 8 Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal sizeFR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) inrecessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & its ISI marked (IS:3419-1988)accessories, Hot Dipped GalvanizedModular box of 1.2 mm thick with earth terminal, 10 A modularswitch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR 9 On board 10 S&F following sizes (dia.) of ISI marked virgin material MMS ( IS:9537 P - III ) PVC conduit along withISI marked (IS:3419-1988) accessories as requiredinrecessincludingcutting the wall, covering conduit and making good the same as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 11 20 mm 12 25 mm 13 32 mm 14 Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 forlower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5,in existingsurface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure A attached with this BSR 15 2 x 2.5 sq. mm. + 1x1.5sqmm 16 1 x 4.0 sq.mm 17 2 x 4.0 sq. mm. + 1 x 2.5 sq. mm. 18 4 x 6.0 sq.mm 19 4 x 10.0 sq.mm 20 P & F 1.2 mm thickG. I. / M .S. Sheet boxes duly finished with two coats of red oxide and with earthing terminal of following sizes (nominal size) in recessed/surface as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 21 1.2 mm thickG Iboxes 22 100mm x 100mm x 60mm 23 P & F paper phenolic resin bondedlaminates confirming to IS : 2036 -1995 for boxes/ frames including making holes for switches etc, with brass screws, washers/ zinc platednut and bolts as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 24 3.0 mm thick 25 P & F phenolic laminated sheet 2.0 mm thick of following size . Including screws, cup washer as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 26 75 mm dia 27 P & F 1.2mm thickM.S. Recessed fan box, hexagonal/ round of size 130 mm dia, depth 75mm,12 mm dia rod fan hook with 100 mmlength extended on each side . All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure A attached with this BSR 28 Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load andsite requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting ofclass 3 as per IEC,minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted inexisting distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above ratingincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 29 Single pole MCB (With B/C curve tripping Characteristics) 30 6 A to 32 A rating 31 Four pole MCB (With B/C curve tripping Characteristics) 32 50/63 A rating 33 Providing & Fixing of Recessed/surface mounting heavy duty horizontal type Double Door ( Metal / Glazed )Distribution board with Metal end box made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3, powder painted complete with reversible door (for double door DB only )100 amp. insulated copper bus bar/shorting link , copper neutral link, copper earth link , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, Ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 34 Metal door (Three phase) IK-09 and IP-43with Metal end box 35 8 Way 36 Providing & Fixing of Recessed/surface mounting heavy duty Vertical TPN Distribution board with Metal end box with provision of incomer suitable for 3/4 pole MCCB and SP / TP MCB as outgoing ,made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3. powder painted with reversible door (for double door DB only ) complete with insulated 160 (upto 160 A Incomer) / 250 Amp. copper bus bar, neutral bars with shrouds, earth bar , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure A attached with this BSR 37 Double door IP-43 & IK-09 with Provision of Incomer MCCB 100/ 125 A Rating with Metal end box 38 4 Way 39 Providing & Fixing ofISI marked (IS:371) 6 amp surface type 3 pin ceiling rose with CM/L no. printed and made out from industrial grade Polycarbonate or fire resistant ABS material, brass terminal & captive screws including making connection testing etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 40 Providing & Fixing of ISI marked (IS:1258) batten/angle lampholder with CM/L no. printed and made out from industrial grade Polycarbonate or fire resistant ABS material, brass terminal & captive screwsincluding making connection testing etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 41 P & F of Industrial plug and socket conforming to IEC 60309-1/2 made out of self extinguishing engineering polymer / polyamide, nickel plated brass sleeve and pins, socket with shutter including making connection etc as reqd. For additional technical parameters of product / work refer Annexure A attached with this BSR 42 IP -67 Surface/Wall mounted socket 43 32 A 3 pin(2P+E) 44 Providing & Fixing of modular type 120 W Step Fan regulator duly ISI marked (IS 11037:1984 ) with CM/L no. printedmade out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating ,includingall as per pre approved by Engineer in charge,making connections, testing etc. as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 45 5 step fan regulator 2 Module 360 dgree rotating 46 SITC of3 /4pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant materialhaving following current rating, short circuitbreaking capacityat 440/415 V, 50 Hz; O/L & S/C settings , conforming to IS/IEC 60947 P -2 :2003 with frontface and centralised adjustable, trip free mechanisum, true contact position indicator,line load interchangeability,designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree,pollution degree 3, having positive isolation capability, push(test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% Icu. U imp =8 KV, rated insulation voltage690 V.provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connectionsetc. as required.OEM shall have submitNABL / CPRI / ERDA accrediated lab type test certificate before execution All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 47 4 pole MCCB With Thermal Magnetic release 48 125 Amp , 25 kA, adjustable O/L & adjustable S/C setting, 49 Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed ArrmouredAluminiumcable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV withH4- Grade electrolyticaluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) includingtesting etc. as required of following size. OEM must have its own in house NABL accrediated Laboratory for testing procedure as per IS:10810.For additional technical parameters of product / work refer Annexure A attached with this BSR 50 50.0 Sq. mm 51 3.5 core 52 Supplyandinstallationofhigh tensile low carbon steel rod molecularly bonded with 99.9 % Copperthickness (250 microns) andconfirming toUL 467, IS/IEC 62561-2of following size and length and as per point mentioned (a), (b), [c), (d), (e) below :- 53 (a) Bore a hole of dia. 100 mm of required length, Place the rod in the centre of Hole 54 (b)filled with anti corrosiveconductivecompounds with the permanent sealings at both the ends, CPRI/ ERDAtested with RMS capacity of minimum 30 KA for withstanding 1 second .To ensure the moisture content and electrical conductivity, 25 kg for 2000 mm & 50 Kgs for 3000mm of resistance lowering earth enhancement material shall be used as a backfill compound. The compound shall be tested form NABL acredeated labfor lowresistivity ( less than 0.12 Ohm - meter ) & high conductivity in nature with carbon as a major contentas per referance of IS 3043-1987,IEEE 80-2013 (clause 14.5d) , IEEE 837 & IER 1956 with latest amendemnts 55 © Connect the rod with copper Strip/Conductor/Wire with suitable clamp made from tinned copper and SS 304 Bolt 56 (d) Place Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height250 to 300 mm. 57 (d)Testing of earth resistance for value of 5 ohms or lessas required & must record by engineer in charge during site visit and ensure to enter in measurment book. 58 (e) Test certificatesfor confirming above standards from OEM is mandatory. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 59 17.2 mm thick and 3 Mtr. Long 60 Supply & Laying following size earth stripin horizontal or vertical run in surface by means of Earth strip DMC Insulatorincluding riveting/ soldering/ welding, Jointing shall be done by overlapping and with 2 set of Brass (for Cu strip) / GI (for GI Strip) nut bolt & spring washer spaced at 50cm making connection etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 61 25mm x 3mm Alum. Strip 62 Providing & Fixing ofBEEStar rated copper wounded double ball bearing capacitor start, aluminium body & Metallicblade ceilingfanConforming to all the performance requirements laid down in IS 374:2019 including all amendments, as applicable ; & Carry BIS licensing (i.e. ISI marking) with down rod up to 80 cm with secondary support safety cable ( steel rope) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 63 1200 mm Sweep BEE 2 Star rated (service value >=4.5 to < 5 ) 64 Providing & Fixing of Heavy duty capacitor start, copper woundDouble ball bearing900/1400 RPM single phaseExhaustfan conforming to IS:2312 ISI marked in existing opening including making connections testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 65 300 mm sweep(900/1400 RPM) 66 380 mm sweep(900/1400 RPM) 67 P & F of Gravity Louver shutter of superior quality made out of frame of18 swg M.S. sheet & Louvers made from 24 swg MS Sheetwith enamel paint including cost of nuts, bolts, etc as reqd.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 68 Up to 380 mm size 69 Providing & Fixing of energy efficient direct fit (Retrofit)Polycarbonate/ GlasshousingSMD Mid Power LED tube rod(with integral driver & alumn. heat sink ), on existing fixture.system lumen efficacy ≥ 100 lm/Watt output, internal surge protection of 2.5 KV ,THD < 20% ,p.f.≥0.95,CRI >80 , life time of minimum35000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80)certificate / Report from OEM shall be submitted.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 70 1200mm , Min. Lumens output 2000 lmLED Tube rod with Polycarbonate Housing 71 Providing & Fixing of IP-20 LED Recessed / Surface Mounted, Round / SqaureSMD Mid Power LED Downlight with power coated die-cast aluminum housingwith UV Stabilized non yellowish Diffuser withBIS complience 2.5 KV surge protected Isolated driver, with Short & Open circuit protection, having efficiency > 85% . System Lumen efficacy of ≥ 110 lm / watt, THD < 10 % , Pf.≥0.95, CRI >80,life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. 72 OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 73 Surface Mounting (with extruded alumn. Housing ) 74 Minimum lumen output 2400 lm 75 Providing & Fixing of IK08, IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminummaterial with heat dissipation fins on housing with UV stabilized PC (UV stablization report submitted for UV cover ) /Toughened Glass coverand secondary lens on each LED & should be SMD type of 3 to 5 watt each . The System efficacy >=125 lm/ wt and potted driver& has a unique BIS R number withInput Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety , Power Factor >0.95 driverEfficiency >85%,THD(I) <10%Humidity 10% to 90% RH Working Temp -5C to 45C .driver current <750mA. The luminaireshall be BIS certified and Trade mark certified. Life ExpectancyEqual or more than 50000 burning hrs with Minimum 70% lumen maintened , CRI >70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external inside driver compartment. driver should be Phase to phase protection of 440 V for 4 Hrs.Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities forLED fixtures.(LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 76 LED Street Light fixture with Minimum lumen output 8700 lm 77 Providing & Fixing of Street light bracket made out from following size of B class , Medium class G.I. Pipe confirming to IS : 1239 P - 1 ( 2004 ) with heavy duty pole clamp, Saddles suitable fastners etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 78 32 mm Dia. 79 Supply, Drawing and Testing of 4 pair, 23 AWG Solid Bare Copper wire insulated with PVC, UTP (Unshielded Twisted Pair), Category 6, Class E, 100 Ohm Impedance, Indoor Cable as per latest ammendments of ANSI/TIA/EIA-568 , The copper conductors should be balanced twisted in pairs, seperated by a cross-member fluted pair divider & protected byPVC Jacket. Certified performance in a 4-connector configuration upto 100 Mtrs channel requirements & transmission frequencies up to 250 Mhz. in existing MS/PVC Conduits/casing capping including making connections to Information outlets and Patch Panels with jack &ferruling at both ends for identification with necessary tools for punching, stripping, crimping and testing etc as required complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 80 Supply and Installation of unsheilded/360 degree sheilded Information outlets made of high impact plastic body with ABS, FR Grade halogen free material with provision for protection against dust in jack, suitable for Cat 6/6A application complying to latest ammendments, According. to Cat. 6/6A channel, It should support channel as well as components requirements of Cat.6/6A standards at frequencies of up to 250 to 500 Mhz. Cat 6/6A unshielded/shielded Jack should be suitable to terminate 4 pair, 23/24 AWG solid/stranded wire diameters, using 100 Ohm unshielded/shielded balance twisted pair cable, the jack should have tooless/impact termination on reliable copper tin plated Insulation displacement contact, with easy lock mechanism, It supports IEC 60603-7-4 and complied with ANSI/TIA/EIA 568 C.2 standard. jack should be RJ11,RJ12 & RJ45 compatible. Should support Ethernet 1.2 Gb/s ATM,Digital video and broadband/baseband analog video, Voice over internet protocal (VOIP) Specifications in existing modular/MS Boxes along with necessory connections as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 81 Cat 6, Un-sheilded Information Outlet 82 Supply & fixing of square Faceplate for Flush / Surface Mount Information Outlets Single/Dual or Quad Aperture ,material should bePC+ABS body, Suitable for RJ45 unshielded/shielded connection modules. Should match with I. O. OEM. Dimensions should be 86mm X 86mm as required complete in all respect.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 83 Single Aperture 84 Supply , Installation and Testing of 4 pair, 100 Ohm impedance, Cat 6/6A /Class E/Ea patch cords should be constructed of minimum 23/24 AWG, stranded bare Copper cable with FRPVC/LSZH Jacket, with an enhanced performance by factory moulded RJ45 connectors with strain relief boots as per ANSI/TIA/EIA 568-C.2 suitable for Cat 6/6A application complying to latest ammendments Category 6/6A Standards, According. to TIA568C.2, ISO/IEC 11801, EN 50173, IEC 60603-7-51, EN 60603-7, IEEE 802.3an minimum requirement for 1G BASE-T to 10G BASE-T performance. Patch cords shall be straight thru cable compatible with both T568-A and T568-B wiring schemes, should support IEEE 802.3af / IEEE 802.3at for POE applications, Minimum 750 to 1000 mating cycles in plug contacts for long durability, Should support Ethernet 10GBASE-T, 1.2 Gb/s ATM, Token ring 4/16, Digital video and broadband/baseband analog video, Voice over internet protocal (VOIP).All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 85 Cat 6, U/UTP (Unscreened/Un-sheilded Twisted Pair) Patch Cord 86 2 Mtr 87 Supply, Installation, OTDR Testing & Fusion Splicing of Fiber Multimode Pigtail (50/125 µm) made of glass fiber optic,should be fitted at one end with any one type of single ST/E-2000/SC/LC/MT-RJ/PC type connector in acc., as per latest ammendments of TIA/EIA 569Standard Specification as per requirments complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 88 Supply, Installation, & Testing of 19 1U Rack Mounted/ surface mounted aluminum/ CRCA 1.2mm powder coated, Singlemode glass Fiber Optic Cable Patch panel/LIU loaded with flangless/screwable duplex adapters for ST/E-2000/SC/LC/MT-RJ/PC type, It should have easy removable Top plate with push buttons, there should be a splice tray installed in the Patch panel/LIU which can handle the fiber cores, splice tray should be PC+ABS material, it should include accessories like mounting hardware, gormetts, heat shrink tubes/sleevs, screws, nuts to install the panel for rack/wallmount applications as per requirment complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 89 12 Ports 90 Supply , Installation, Testing and Comissioning ofManaged Layer-2 Intelligent 10/100 Ethernet Switch providing 24 x 10/100/1000 MBPS Giga Ethernet ports / with min 2 SFP Giga Ports (provision for Fiber Giga connectivity) with related LAN Base Software including making connections etc as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 91 Supply , Installation, Testing and Comissioning ofInverter type Air Cooled Hi Wall split type Air conditioners with latest star rating system as per BEE amended upto date complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU), R-32/R-410 Green Refrigerant, wireless Remote control, suitable for working between 230V +/- 10% with low & high voltage cutoff and50 hz , single phaseACsupply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 92 1.5 TR ISEER not less then 3.8 93 Supply, Fixing and testing of following capacity ISO certified company made wall mounted stabilizer having output voltage variation from 200 V to 250 V(+/-5%) with input voltage variation from 170 V to 260 V, time delay facility from 2 to 4 minute and high cutoff at 270 V with providing of 16 Amp /20 Amp Industrialplug top making connection etc complete in all respect.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 94 4 kVA 95 Making hole in stone masonary/ RCC wall/ RCC slab with core cutter for accomodating refrigerant pipe/ drain pipe/ MS pipe/ cables etc of following dia 96 100 mm dia per running inch length 97 Providing & Fixing of IS : 4985 - 2000 Class -4 (10 Kgf / Sqcm) UPVC drain water piping withfittings (IS:7834 & 10Kgf/sqcm) like elbow, socket, Tee, solvent cement jointing,support with MS hanger on ceiling or recessed in wallwith chasing & plastering with 6 mmthickclosedcellelastomeric nitrile rubberinsulation including leakage testing etc. as required of following Nominal sizes. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 98 20 mm 99 Supply & fixing MS powder coated stand suitable for 1.0/1.5/ 2.0 Tr outdoor type of Split AC.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 100 Supply & Fixing of Dry Powder Agent (as per IS 4308:2019), ABC typeFire Extinguisher (Stored Pressure type) conforming to IS:15683:2018 , Powder coated Internal & External Surface Deep drawn cylinder body of Mild Steel CR2 grade conforming to IS: 513, Squeeze grip Forged brass release valve with Inbuilt safety release device, Diaphragm Type, 0 to 28 bar range pressure gauge, 450 mm long EPDM discharge tube, QR code for Product Traceability including Fixing on wall with suitable Anchor Fasteners as required of following capacity. Test Certificates of all the Parameters along with Hydro test & Burst test (For Cylinder Body) Certificatefrom OEM / External NABL Accrediated Lab is to be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 101 4 kg
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 1
18.
Health and Family Welfare #10416328 Price Bid
Tender For supply of Ct Simulator , 4D Ct Simulator As Per The Specification Except The Following , One Set Of 3 External Static Laser System , Laser Qa Tool , Laser Printer Duplex A4 , Laser Printer Duplex A3 , Single Head Pressure Injector With 100 Syringes , Water Bath / Oven , Full System Ups , Lead Apron With Thyriod Gurad , Lead Glove , Gonad Shield , Additional Workstation As Per Spec (Not Taken For Evaluation) , Dry Imager (Not Taken For Evaluation) , 15.3 Demolishing R.C.C. Work Manually / By Mechanical Means Including Stacking Of Steel Bars And Disposal Of Unserviceable Material With In 50 Metres Lead As Per Direction Of Engineer -In-Charge. , 15.7.4 Demolishing Brick Work Manually / By Mechanical Means Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Metres Lead As Per Direction Of Engineer-In-Charge.In Cement Mortar , 15.12.1 Dismantling Doors, Windows And Clerestory Windows (Steel Or Wood ) Shutter Including Chowkhats, Architrave, Holdfasts Etc. Complete And Stacking Within 50 Metres Lead:Of Area 3 Sq. Metres And Below , 15.12.2Dismantling Doors, Windows And Clerestory Windows (Steel Or Wood ) Shutter Including Chowkhats, Architrave, Holdfasts Etc. Complete And Stacking Within 50 Metres Lead: Of Area Beyond 3 Sq. Metre , 15.23.1Dismantling Tile Work In Floors And Roofs Laid In Cement Mortar Including Stacking Material Within 50 Metres Lead.For Thickness Of Tiles 10 Mm To 25 Mm , 15.57 Dismantling Aluminium / Gypsum Partitions, Doors, Windows, Fixed Glazing And False Ceiling Including Disposal Of Unserviceable Surplus Material And Stacking Of Serviceable Material With In 50 Metres Lead As Directed By Engineer - In-Charge , 2.34.1Supplying Chemical Emulsion In Sealed Containers Including Delivery As Specified.Chlorpyriphos / Lindane Emulsifiable Concentrate Of 20% , 2.35.1.1Diluting And Injecting Chemical Emulsion For Post -Constructional Anti-Termite Treatment (Excluding The Cost Of Chemical Emulsion):Along External Wall Where The Apron Is Not Provided Using Chemical Emulsion @ 7.5 Litres / Sqm Of The Vertical Surface Of The Substructure To A Depth Of 300Mm Including Excavation Channel Along The Wall & Rodding Etc. Complete: With Chlorpyriphos /Lindane E.C. 20% With 1% Concentration , 24.2Providing And Fixing Double Scaffolding System (Cup Lock Type ) On The Exterior Side Of Building/Structure, Upto 25 Metre Height, Above Ground Level, Including Additional Rows Of Scaffolding In Stepped Manner As Per Requirement Of Site, Made With 40 Mm Dia M.S. Tube, Placed 1.5 Metre Centre To Centre, Horizontal & Vertical Tubes Joint With Cup & Lock System With M.S. Tubes, M.S. Tube Chakkus, M.S. Clamps And Staircase System In The Scaffolding For Working Platform Etc. And Maintaining It In A Serviceable Condition For Execution Of Work Of Cleaning And / Or Pointing And / Or Applying Chemical And Removing It Thereafter. The Scaffolding System Shall Be Stiffened With Bracings, Runners, Connecting With The Building Etc, Wherever Required, If Feasible, For Inspection Of Work At Required Locations With Essential Safety Features For The Workmen Etc., Complete As Per Directions And Approval Of Engineer-In-Charge. Note: - ( 1) The Evaluational Area Of The Scaffolding Shall Be Measured For Payment Purpose, (2) The Payment Will Be Made Once Only For Execution Of All Items Of Such Works. , 15.60 Disposal Of Building Rubbish/ Malba/ Similar Unserviceable, Dismantled Or Waste Materials By Mechanical Means, Including Loading, Transporting, Unloading To Approved Municipal Dumping Ground Or As Approved By Engineer-In-Charge, Beyond 50 M Initial Lead, For All Leads Including All Lifts Involved , 50.2.25.1 Filling With Contractors Own Earth ( Excluding Rock) In Trenches, Plinth, Sides Of Foundations Etc. In Layers Not Exceeding 20 Cm In Depth, Consolidating Each Deposited Layer By Ramming And Watering, Lead Up To 50 M And Lift Up To 1.5 M As Per Direction Of Site Engineer-In-Charge , 50.4.1.1 Providing And Laying In Position Cement Concrete 1:2:4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 12.5 Mm Nominal Size) Up To Floor Five Level Excluding The Cost Of Centering, Shuttering, Finishing For Leveling Coarse Of Floor And Roof Etc. , 50.5.5Reinforced Cement Concrete Work In Arches, Archribs, Domes, Vaults, Shells, Folded Plate And Roof Having Slope More Than 15 Degree Up To Floor Five Level Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement With 1:1.5:3 ( 1 Cement : 1.5 Coarse Sand: 3 Graded Stone Aggregate 20 Mm Nominal Size). , 50.5.33.2 Providing And Laying In Position Machine Batched And Machine Mixed Design Mix M-20 Grade Cement Concrete For Reinforced Cement Concrete Work, Using Cement Content As Per Approved Design Mix, Including Pumping Of Concrete To Site Of Laying But Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement, Including Admixtures In Recommended Proportions As Per Is: 9103 To Accelerate, Retard Setting Of Concrete, Improve Workability Without Impairing Strength And Durability As Per Direction Of Engineer-In-Charge. Note:- Cement Content Considered In This Item Is @ 330 Kg/Cum. Excess Or Less Cement Used As Per Design Mix Is Payable Or Recoverable Separately. All Work Above Plinth Level Upto Floor V Level , 5.22.1 Steel Reinforcement For R.C.C Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Upto Plinth Levelmild Steel And Medium Tensile Steel Bars , 5.9.3 Centering And Shuttering Including Strutting, Etc. And Removal Of Form For: Suspended Floors, Roofs, Landings, Balconies And Access Platform , 2.1.1 Earth Work In Surface Excavation Not Exceeding 30 Cm In Depth But Exceeding 1.5M In Width As Well As 10 Sqm On Plan Including Disposal Of Excavated Earth Up To 50 M And Lift Up To 1.5 M, Disposed Soil To Be Levelled And Neatly Dressed:All Kinds Of Soil , 6.26.2Brick Work With Common Burnt Clay Selected F.P.S (Non Modular ) Bricks Of Class Designation 7.5 In Exposed Brick Work Including Making Horizontal And Vertical Grooves 10 Mm Wide 12 Mm Deep Complete In Cement Mortar 1:6 ( 1 Cement : 6 Coarse Sand)Above Plinth Level And Upto Floor V Level , 50.6.1.2Solid Block Masonry Using Pre Cast Solid Blocks (Factory Made) Of Size 40X20x20cm Or Nearest Available Size Confirming To Is 2185 Part I Of 1979 For Super Structure Up To Floor Two Level Thickness 20Cm And Above In: Cm 1:6 ( 1 Cement: 6 Coarse Sand) Etc Complete. , 50.6.1.8 Solid Block Masonry Using Pre Cast Solid Blocks (Factory Made) Of Size 40X20x15cm Or Nearest Available Size Confirming To Is 2185 Part I Of 1979 For Super Structure Up To Floor Two Level With Thickness 15Cm In: Cm 1:6 ( 1 Cement : 6 Coarse Sand Etc Complete , 50.6.3.2 Solid Block Masonry Using Pre Cast Solid Blocks (Factory Made) Of Size 40X20x10 Cm Or Nearest Available Size Confirming To Is 2185 Part I Of 1979 For Super Structure Up To Floor Two Level For 10 Cm Thick Wall In : Cm 1:6 ( 1 Cement : 6 Coarse Sand) Including Cost Of Scaffolding Complete , 13.1.1Cement Plaster12 Mmof Mix: 1:4 ( 1 Cement : 4 Fine Sand) , 13.7.1Cement Plaster 12 Mmfinished With A Floating Coat Of Neat Cement Of Mix: 1:3 ( 1 Cement : 3 Fine Sand) , 11.37Providing And Laying Ceramic Glazed Floor Tiles Of Size 300X300 Mm (Thickness To Be Specified By The Manufacturer), Of 1St Quality Conforming To Is : 15622, Of Approved Make, In Colours Such As White, Ivory, Grey, Fume Red Brown, Laid On 20 Mm Thick Cement Mortar 1:4 (1 Cement : 4 Coarse Sand), Including Pointing The Joints With White Cement And Matching Pigment Etc., Complete. , 11.41.2 Providing And Laying Vitrified Floor Tiles In Different Sizes (Thickness To Be Specified By The Manufacturer) With Water Absorption Less Than 0.08% And Conforming To Is : 15622, Of Approved Make, In All Colours And Shades, Laid On 20 Mm Thick Cement Mortar 1:4(1 Cement : 4 Coarse Sand), Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete. Size Of Tile 600 X 600 Mm. , 11.41.3 Providing And Laying Vitrified Floor Tiles In Different Sizes (Thickness To Be Specified By The Manufacturer) With Water Absorption Less Than 0.08% And Conforming To Is : 15622, Of Approved Make, In All Colours And Shades, Laid On 20 Mm Thick Cement Mortar 1:4(1 Cement : 4 Coarse Sand), Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete.Size Of Tile 800X 800 Mm , Od31976/2023_2024Providing And Fixing First Quality Vitrified Wall Tiles Conforming To Is: 15622 (Thickness To Be Specified By The Manufacturer), Of Approved Make, In All Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Engineer-In-Charge, In Skirting, Risers Of Steps And Dados, Over 12 Mm Thick Bed Of Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) And Jointing With Grey Cement Slurry @ 3.3Kg Per Sqm, Including Pointing In White Cement Mixed With Pigment Of Matching Shade Complete. , 11.48.2 Grouting The Joints Of Flooring Tiles Having Joints Of 3 Mm Width, Using Epoxy Grout Mix 0.70 Kg Of Organic Coated Filler Of Desired Shade (0.10 Kg Of Hardener And 0.20 Kg Of Resin Per Kg). Including Filling /Grouting And Finishing Complete As Per Direction Of Engineer-In-Charge. Size Of Tile 600X600 Mm , 11.48.3Grouting The Joints Of Flooring Tiles Having Joints Of 3 Mm Width, Using Epoxy Grout Mix 0.70 Kg Of Organic Coated Filler Of Desired Shade (0.10 Kg Of Hardener And 0.20 Kg Of Resin Per Kg). Including Filling /Grouting And Finishing Complete As Per Direction Of Engineer-In-Charge.Size Of Tile 800X800mm , 11.55.1 Providing And Laying Flamed Finish Granite Stone Flooring In Required Design And Patterns, In Linear As Well As Curvilinear Portions Of The Building All Complete As Per The Architectural Drawings With 18 Mm Thick Stone Slab Over 20 Mm (Average) Thick Base Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) Laid And Jointed With Cement Slurry And Pointing With White Cement Slurry Admixed With Pigment Of Matching Shade Including Rubbing, Curing And Polishing Etc. All Complete As Specified And As Directed By The Engineer-In-Charge :Flamed Finish Granite Stone Slab Jet Black, Cherry Red, Elite Brown, Cat Eye Or Equivalent. , 50.9.1.1Providing Wood Work In Frames Of Doors, Windows, Clerestory Windows And Other Frames, Wrought Framed And Fixed In Position With Hold Fast Lugs Or With Dash Fasteners Of Required Dia & Length (Hold Fast Lugs Or Dash Fastener Shall Be Paid For Separately), Using Good Quality Anjili Wood /Jack Wood , 50.9.2.1Providing And Fixing Paneled And Glazed Shutters For Doors, Windows And Clerestory Windows, 35 Mm Thick Shutters Including Isi Marked M.S. Pressed Butt Hinges Bright Finished Of Required Size With Necessary Screws, Excluding Panelling Which Will Be Paid For Separately, All Complete As Per Direction Of Engineerin - Charge. Using Anjili/ Jack Wood , 21.1.1.2 Providing And Fixing Aluminium Work For Doors, Windows, Ventilators And Partitions With Extruded Built Up Standard Tubular Sections/ Appropriate Z Sections And Other Sections Of Approved Make Conforming To Is : 733 And Is: 1285, Fixing With Dash Fasteners Of Required Dia And Size, Including Necessary Filling Up The Gaps At Junctions, I.E. At Top, Bottom And Sides With Required Epdm Rubber/ Neoprene Gasket Etc. Aluminium Sections Shall Be Smooth, Rust Free, Straight, Mitred And Jointed Mechanically Wherever Required Including Cleat Angle, Aluminnium Snap Beading For Glazing /Paneling, C.P. Brass/ Stainless Steel Screws, All Complete As Per Architectural Drawings And The Directions Of Engineer-In-Charge.(Glazing, Paneling And Dash Fasteners To Be Paid For Separately): For Fixed Portionpowder Coated Aluminium (Minimum Thickness Of Powder Coating 50 Micron) , 21.1.2.2 For Shutters Of Doors, Windows & Ventilators Including Providing And Fixing Hinges / Pivots And Making Provision For Fixing Of Fittings Wherever Required Including The Cost Of Epdm Rubber/ Neoprene Gasket Required (Fittings Shall Be Paid For Separately) Powder Coated Aluminium (Minimum Thickness Of Powder Coating 50 Micron) , Providing And Fixing 12 Mm Thick Prelaminated Particle Board Flat Pressed Three Layer Or Graded Wood Particle Board Conforming To Is : 12823 Grade I Type Ii, In Panelling Fixed In Aluminum Doors, Windows Shutters And Partition Frames With C.P. Brass / Stainless Steel Screws Etc. Complete As Per Architectural Drawings And Directions Of Engineer - In- Charge.Pre- Laminated Particle Board With Decorative Lamination On Both Sides , Od31977/2023_2024 Supplying And Fixing Flush Door Shutter, Shutter Of Required Size, Thickness 30Mm Thick, Finished With 1 Mm Laminate Of Approved Shade With 9 X 16 Clear Glass Vision Panels As Per Design Including Necessary Hinges , Od31978/2023_2024 Frosted Film - Supply And Installation Of 3M Make Frosted Film Pattern Throughout All The Internal Glass Panels Wherever Required Of Approx. 1.5 M Height As Per The Approved Pattern. , Od31979/2023_2024 Providing And Fixing Extruded Section Body Tubular Type Universal Hydraulic Door Closer(Having Brand Logo With Is: 3564, Embossed On The Body, Door Weight Upto 36 Kg To 80 Kg And Door Width From 701 Mm To 1000 Mm), With Double Speed Adjustment With Necessary Accessories And Screws Etc. Complete , Od31980/2023_2024 Providing And Fixing 4.00 Mm Thick Acp Sheet For Cupboard Including All Cost, Conveyance, Labour Charges Etc Complete , 21.3.1 Providing And Fixing Glazing In Aluminium Door, Window, Ventilator Shutters And Partitions Etc. With Epdm Rubber / Neoprene Gasket Etc. Complete As Per The Architectural Drawings And The Directions Of Engineer - In -Charge. ( Cost Of Aluminium Snap Beading Shall Be Paid In Basic Item): With Float Glass Panes Of 4.0 Mm Thickness , 12.45.2 Providing And Fixing False Ceiling At All Height Including Providing And Fixing Of Frame Work Made Of Special Sections, Power Pressed From M.S. Sheets And Galvanized With Zinc Coating Of 120 Gms/ Sqm (Both Side Inclusive) As Per Is : 277 And Consisting Of Angle Cleats Of Size 25 Mm Wide X 1.6 Mm Thick With Flanges Of 27 Mm And 37 Mm, At 1200 Mm Centre To Centre, One Flange Fixed To The Ceiling With Dash Fastener 12.5 Mm Dia X 50 Mm Long With 6 Mm Dia Bolts, Other Flange Of Cleat Fixed To The Angle Hangers Of 25X10x0.50 Mm Of Required Length With Nuts & Bolts Of Required Size And Other End Of Angle Hanger Fixed With Intermediate G.I. Channels 45X15x0.9 Mm Running At The Spacing Of 1200 Mm Centre To Centre, To Which The Ceiling Section 0.5 Mm Thick Bottom Wedge Of 80 Mm With Tapered Flanges Of 26 Mm Each Having Lips Of 10.5 Mm, At 450 Mm Centre To Centre, Shall Be Fixed In A Direction Perpendicular To G.I. Intermediate Channel With Connecting Clips Made Out Of 2.64 Mm Dia X 230 Mm Long G.I. Wire At Every Junction, Including Fixing Perimeter Channels 0.5 Mm Thick 27 Mm High Having Flanges Of 20 Mm And 30 Mm Long, The Perimeter Of Ceiling Fixed To Wall/Partition With The Help Of Rawl Plugs At 450 Mm Centre, With 25 Mm Long Dry Wall Screws @ 230 Mm Interval, Including Fixing Of Gypsum Board To Ceiling Section And Perimeter Channel With The Help Of Dry Wall Screws Of Size 3.5X25 Mm At 230 Mm C/C, Including Jointing And Finishing To A Flush Finish Of Tapered And Square Edges Of The Board With Recommended Jointing Compound, Jointing Tapes, Finishing With Jointing Compound In 3 Layers Covering Upto 150 Mm On Both Sides Of Joint And Two Coats Of Primer Suitable For Board, All As Per Manufacturers Specification And Also Including The Cost Of Making Openings For Light Fittings, Grills, Diffusers, Cutouts Made With Frame Of Perimeter Channels Suitably Fixed, All Complete As Per Drawings, Specification And Direction Of The Engineer In Charge But Excluding The Cost Of Painting With: 12.5 Mm Thick Tapered Edge Gypsum Fire Resistant Board Conforming To Is; 2095-Part I , 12.54.1 Providing And Fixing Gi Clip In Metal Ceiling System Of 600X600 Mm Module Which Includes Providing And Fixing C Wall Angle Of Size 20X30x20 Mm Made Of 0.5 Mm Thick Pre Painted Steel Along The Perimeter Of The Room With Help Of Nylon Sleeves And Wooden Screws At 300 Mm Center To Centre, Suspending The Main C Carrier Of Size 10X38x10 Mm Made Of G.I Steel 0.7 Mm Thick From The Soffit With Help Of Soffit Cleat 37X27x25x1.6 Mm, Rawl Plugs Of Sixe38x12 Mm And C Carrier Suspension Clip And Main Carrier Bracket At 1000 Mm C/C. Inverted Triangle Shaped Spring Tee Having Height Of 24 Mm And Width Of 34 Mm Made Of Gi Steel 0.45 Mm Thick Is Then Fixed To The Main C Carrier And In Direction Perpendicular To It At 600 Mm Centers With Help Of Suspension Brackets. Wherever The Main C Carrier And Spring T Have To Join, C Carrier And Spring T Connectors Have To Be Used. All Sections To Be Galvanized @ 120 Gms/Sqm (Both Side Inclusive), Fixing With Clip In Tiles Into Spring T With :Gi Metal Ceiling Clip In Plain Beveled Edge Global White Color Tiles Of Size 600X600 And 0.5Mm Thick With 25 Mm Height, ,Made Of G.I Sheet Having Galvanizing Of 100 Gms/ Sqm (Both Sides Inclusive) And Electro Statically Polyester Powder Coated Of Thickness 60 Microns (Minimum), Including Factory Painted After Bending . , 12.58.1 Providing And Fixing Tiled False Ceiling Of Approved Materials Of Size 595X595 Mm In True Horizontal Level, Suspended On Interlocking Metal Grid Of Hot Dipped Galvanized Steel Sections (Galvanized @ 120 Grams/ Sqm, Both Side Inclusive) Consisting Of Main T Runner With Suitably Spaced Joints To Get Required Length And Of Size 24X38 Mm Made From 0.30 Mm Thick (Minimum) Sheet, Spaced At 1200 Mm Center To Center And Cross T Of Size 24X25 Mm Made Of 0.30 Mm Thick (Minimum) Sheet, 1200 Mm Long Space Between Main T At 600 Mm Center To Center To Form A Grid Of 1200X600 Mm And Secondary Cross T Of Length 600 Mm And Size 24X25 Mm Made Of 0.30 Mm Thick (Minimum) Sheet To Be Interlocked At Middle Of The 1200X600 Mm Panel To Form Grids Of 600X600 Mm And Wall Angle Of Size 24X24x0.3 Mm And Laying False Ceiling Tiles Of Approved Texture In The Grid Including, Required Cutting/Making, Opening Of Services Like Diffusers, Grills, Light Fittings, Fixtures, Smoke Detectors Etc. Main T Runners To Be Suspended From Ceiling Using Gi Slotted Cleats Of Size 27 X 37 X 25 X 1.6 Mm Fixed To Ceiling With 12.5 Mm Dia And 50 Mm Long Dash Fasteners, 4 Mm Gi Adjustable Rods With Galvanized Butterfly Level Clips Of Size 85 X 30 X 0.8 Mm Spaced At 1200 Mm Center To Center Along Main T, Bottom Exposed Width Of 24 Mm Of All T-Sections Shall Be Pre-Painted With Polyester Paint, All Complete For All Heights As Per Specifications, Drawings And As Directed By Engineer-In-Charge. 8Mm Thick Fully Perforated Calcium Silicate Board Made With Calcareous & Siliceous Materials Reinforced With Cellulose Fiber Manufactured Through Autoclaving Process To Give Stable Crystalline Structure With Minimum Compressive Strength 225 Kg/ Sq. Cm, Bending Strength 100 Kg/Sq. Cm, Of Size 595X595 Mm, Having Perforation Of Dia, 10 Mm With Minimum Perforated Area 18% With Non Woven Tissue On The Back Side, Having An Nrc (Noise Reduction Coefficient) Of 0.85, With 50 Mm Thick Rockwool Of 48 Kg/Cum Backing. , 21.4.2Providing And Fixing Double Action Hydraulic Floor Spring Of Approved Brand And Manufacture Conforming To Is: 6315, Having Brand Logo Embossed On The Body / Plate With Double Spring Mechanism And Door Weight Upto 125 Kg, For Doors Including Cost Of Cutting Floors, Embeding In Floors As Required And Making Good The Same Matching To The Existing Floor Finishing And Cover Plates With Brass Pivot And Single Piece M.S. Sheet Outer Box With Slide Plate Etc. Complete As Per The Direction Of Engineer -In- Charge.With Brass Cover Plate Minimum 1.25 Mm Thickness , 21.13 Providing And Fixing 100 Mm Brass Locks ( Best Make Of Approved Quality ) For Aluminium Doors Including Necessary Cutting And Making Good Etc. Complete , 50.9.11.1Providing And Fixing Thomson Multi Wood Board Or Equivalent Make Paneling 12 Mm Thick, To Frame, Backing Or Studding With Screws Etc. Complete ( Frames, Backing Or Studding To Be Paid Separately) As Per The Direction Of Site Engineer-In-Charge. , 50.9.12.1 Providing And Fixing Thomson Multi Wood Board Or Equivalent Make, In Shelves With Screws And Fittings Wherever Required, Edges To Be Painted With Polyurethane Primer (Fittings To Be Paid Separately) As Per The Direction Of Site Engineer-In-Charge. , 13.61.1 Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture To Give An Even Shade:Two Or More Coats On New Work , 13.69.1 Polishing On Wood Work With Ready Mixed Wax Polish Of Approved Brand And Manufacture: New Work , 13.80Providing And Applying White Cement Based Putty Of Average Thickness 1 Mm, Of Approved Brand And Manufacturer, Over The Plastered Wall Surface To Prepare The Surface Even And Smooth Complete. , 13.83.2Wall Painting With Premium Acrylic Emulsion Paint Of Interior Grade, Having Voc (Volatile Including Applying Additional Coats Wherever Required To Achieve Even Shade And Colour.Two Coats , 13.47.1Finishing Walls With Premium Acrylic Smooth Exterior Paint With Silicone Additives Of Required Shade:New Work (Two Or More Coats Applied @ 1.43 Ltr/ 10 Sqm Over And Including Priming Coat Of Exterior Primer Applied @ 2.20 Kg/ 10 Sqm) , 10.16.3 Steel Work In Built Up Tubular (Round, Square Or Rectangular Hollow Tubes Etc.) Trusses Etc., Including Cutting, Hoisting, Fixing Position And Applying A Priming Coat Of Approved Steel Primer, Including Welding And Bolted With Special Shaped Washers Etc. Complete.Electric Resistance Or Induction Butt Welded Tubes , Od31981/2023_2024Roofing Sheet With Sandwich Puf Roof Panel With 0.40 Mm Or Nearest Size Pre Painted Galvalume Sheet At Top & Bottom , 30 Mm Or Nearest Size Puf Sheet At Middle Portion , Necessary Overlap At Ends Including Self Screws, Cyclone Washer Etc. Complete , Od31982/2023_2024 Wall Cladding With Sandwich Puf Wall Panel With 0.40 Mm Or Nearest Pre Painted Galvalume Sheet At Top &Bottom , 30 Mm Or Nearest Puf Sheet At Middle Portion , Necessary Overlap At Ends Including Self Screws, Cyclone Washer Etc. Complete. , Od31983/2023_2024 Providing At All Heights, Levels And Locations 0.45 Mm Thick Galvalume Sheet Of Alloy 31500/31000/40800, Conforming To Is 1254, Is 737, Is 2676. The Sheet Shall Be Fixed Using Self Drilling/Self Tapping Ss Screws Of Size 5.5X65 Mm With Epdm Seal Complete Upto Required Pitch In Horizontal, Vertical Or Curved Surfaces I/C Cutting To Size And Shape Where Required As Per The Direction Of Engineer-In-Charge. The Rate Shall Be Inclusive Of All Screws, Seal, Ridge, Labour, Scaffolding, Machinery For Fixing And Approved Sealant Where Required Etc. But Excluding The Cost Of Purlins, Rafters And Trusses. , 17.2.2 Providing And Fixing White Vitreous China Pedestal Type Water Closet (European Type W.C. Pan) With Seat And Lid, 10 Litre Low Level White P.V.C. Flushing Cistern, Including Flush Pipe, With Manually Controlled Device (Handle Lever), Conforming To Is : 7231, With All Fittings And Fixtures Complete, Including Cutting And Making Good The Walls And Floors Wherever Required: W.C. Pan With Isi Marked Black Solid Plastic Seat And Lid , 17.7.1 Providing And Fixing Wash Basin With C.I. Brackets, 15 Mm C.P. Brass Pillar Taps, 32 Mm C.P. Brass Waste Of Standard Pattern, Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls Wherever Require: White Vitreous China Wash Basin Size 630X450 Mm With A Pair Of 15 Mm C.P. Brass Pillar Taps , 50.17.1.2 Supplying And Fixing Cp Towel Rod 45Cm Or Nearest Available Length Including Cost Of Materials And Labour Charges Etc Complete As Per The Direction Of Site Engineer-In-Charge , 50.17.1.5Supplying And Fixing Cp Health Faucet Superior Quality ( Jagur Or Equvalent Make ) Including Cost Of Materials And Labour Charges Etc Complete As Per The Direction Of Site Engineer-In-Charge. , 50.17.1.1 Supplying And Fixing Stainless Steel Soap Dish Including Cost Of Materials And Labour Charges Etc Complete As Per The Direction Of Site Engineer-In-Charge. , 17.31 Providing And Fixing 600X450 Mm Beveled Edge Mirror Of Superior Glass (Of Approved Quality) Complete With 6 Mm Thick Hard Board Ground Fixed To Wooden Cleats With C.P. Brass Screws And Washers Complete. , Od33878/2023_2024 Supplying And Fixing Stainless Steel Mirror Finished H Type Handles Including Material Cost, Conveyance And Fixing Charges Etc Complete. , 50.18.7.1.1 Providing And Fixing Pvc Pipes, Fittings Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer-In-Charge 15Mm Dia 12Kgf/Cm2 -Internal Work- Exposed On Wall , 50.18.7.4.1Providing And Fixing Pvc Pipes, Fittings Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer-In-Charge 32 Mm Dia 10Kgf/Cm2- Internal Work - Exposed On Wall , 50.18.8.1.1 Providing And Fixing Pvc Pipes, Fittings Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer- In- Charge. Concealed Work, Including Cutting Chases And Making Good The Wall Etc. 15 Mm Pipe 12 Kgf/ Cm2 , 50.18.8.4.1Providing And Fixing Pvc Pipes, Fittings Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer-In-Charge. Concealed Work, Including Cutting Chases And Making Good The Wall Etc. 32 Mm Pipe 10Kgf/Cm2 , 50.18.8.9.1Providing And Fixing Pvc Pipes, Fittings Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer-In-Charge. Concealed Work, Including Cutting Chased And Making Good The Wall Etc. 110 Mm Pipe 6Kgf/Cm2 , 50.18.9.8.2 Providing And Fixing Pvc Pipes Includings Of Pipes With One Step Pvc Solvent Cement, Trenching And Refilling & Testing Of Joints Complete As Per Direction Of Engineer In Charge. 75 Mm Dia 4 Kgf/Cm2 , Od31984/2023_2024 Providing And Fixing 24 Mm Thick Factory Made Pvc Door Shutters Made Of Styles And Rails Of A Pvc Hollow Section Of Size 59 X 24 Mm And Wall Thickness 2 Mm With Inbuilt Edging On Both Sides. The Styles And Rails Mitered And Joint At The Corners By Means Of M.S. Galvanized/Plastic Brackets Of Size 75 X 220 Mm Having Wall Thickness 1.0 Mm And Stainless Steel Screws. The Styles Of The Shutter Reinforced By Fixing Galvanized M.S. Tube Of Size 20 X 20 Mm And 1 Mm Wall Thickness. The Lock Rail Made Up Of H Section, A Pvc Hollow Section Of Size 100 X 24 Mm And 2 Mm Wall Thickness,Fixed To The Shutter Styles By Means Of Plastic/Galvanized M.S. U Cleats. The Shutter Frame Filled With A Pvc Multi-Chambered Single Panel Of Size Not Less Than 620 Mm, Having Over All Thickness Of 20 Mm And 1 Mm Wall Thickness. The Panels Filled Vertically And Tie Bar At Two Places By Fixing Horizontally 6 Mm Galvanized M.S. Rod And Fastened With Nuts And Washers, Complete As Per Manufacturers Specification And Direction Of Engineer-In-Charge( For W.C. And Bathroom Door Shutter). , Od31985/2023_2024 Supplying And Fixing Name Board Of Various Sizes Using Foam Sheet Board Including Lettering As Per The Direction Of Departmental Officers Including Cost, Conveyance And Fixing Charges Etc Complete. 45X14cm Size , Od31986/2023_2024 Supplying And Fixing The Name Board Of Size 80 X 30 Using Acp Board With Acrylic Lettering Including Cost, Conveyance And Labour Charges For Lettering And Fixing Etc Complete , Od31987/2023_2024 Supplying And Fixing Inaugration Board Using Granite Slab Including Lettering As Per Direction Of Departmental Officers Including Cost Of Granite, Lettering And Fixing Charges Etc Complete. Size: 100X84cm , Supplying And Fixing Skylight Of Size 1.2Mx 1.8M With Designed Acrylic Sheet Including 4 Numbers Led Tube As Per The Direction Of Engineer In Charge , Od31989/2023_2024 Computer Chair The Medium Back Adjustable Revolving Chair Made With Mesh Back Within Built Handle In The Nylon Finish, The Back Is Designed Extra Lumber Support. The Seat Have Provided Seat Cover In Pp Made With 12Mm Hot Pressed Ply And Pu Moylded Foam. The Tilting Mechanism Should Be Synchro-Tilt Mechanism As Per International Ergonomics Standards Any Position Locking. The Base And Pin Wheels Are Made In The Nylon. 120Mm H Gas Lift Should Be Provided With Tower Bellow , Od31990/2023_2024 High Back Chair Made With Feather Foam Seat & Mesh Back With Lumber Support. , The Gas Lift Mechanism Should Be Tested As Per Bifmastandards. The Pedestal Should Be Five Legged Injection Mouldedin Black 30% Glass –Filled Nylon And Fitted With 5 Nos Twin Wheel Castors. The Castors Of The Chairs Should Be Glass Filled, It Should Have Synchro Any Anglelocking Arrangement , Od31991/2023_2024Providing And Fixing Trap Doors For Access To The Areas Above False Ceiling. The Trap Door Shall Have An External Frame Made Of Powder Coated Aluminium Channel On Which The Shutter Is Hinged. Shutter Shall Be Made 3 Mm Thick Acp Sheet Shutter External Frame Of Shutter Made Of Powder Coated Aluminium Channel. Concealed Heavy Duty Hinges Shall Be Used To Mount The Shutters And Locking Shall Be Provided. The Shutter Shall Be Moulded In Level With The False Ceiling Forming A Groove All Around. Sufficient Number Of Hinges And Locks Shall Be Provided To Avoid Sagging Of The Shutter. Key Also Shall Be Supplied. No Extra Rate Shall Be Provided For Suspenders Or Frame Works All Round For Linking The Trap Door To Gyp Board /Any Other False Ceiling. The Rate Including All Labour Charges ,Material Charges Ect Complete. , Od33559/2023_2024 Supplying And Laying Polyster , Washable And Stainfree Cloth(Bio-Active Fabric Washable Germfree-Suitable For Icu Room) Curtain System With Maximum Curtain Cloth Height 230Cm (Top 30 Cm White Colour Net And 200Cm Light Blue Colour As Per Approval) Stitching With Stifiner Tape,Pleats,Ironing And Laying In Icu Room Around Each Bed Using Pvc Runner With Hooks&Stopper For Hanging/Sliding Etc. As Per The Direction Of Engineer In Charge Including Conveyance To Site , Laying In Line And Level , Sealing All Cuttings In False Ceiling With Powder Coated Ms Cup ,All Leads And Lifts Including All Labour Charges Etc. Complete.(Unpleated Length Of The Cloth Maesurement Will Be Considered For Payment Also The Bottom And Top Foldings Will Not Be Considered In Cloth Measuremnet)/Supplying And Fixing Powder Coated 20Mm Dia. Gi Round Tube Hanging Support Of Required Length (App. Length 1.10M) One End Fixing From Slab By Using 6Mm Dia. Expansion Bolt At A Distance Not More Than 2 M, C/C Down End Fixed To Powder Coated Aluminium Channel Frame 45X20mm X1mm Thick Section By Using Ss Screw As Per The Direction Of Engineer In Charge Including Conveyance To Site, Laying In Line And Level ,Sealing All Gaps In False Ceiling Due To Hanging Supports ,All Leads And Lifts, Including All Labour Charges Etc. Complete. , Od33560/2023_2024 Providing And Fixing Vertical Blinds As Per The Direction Of Engineer In Charge , Furniture& Other Works: Lead Lined Door Shutters: 2Mm Lead Lined Door Shutterswithsolid Cored(30Mm) Lead(2Mm) Lined Flush Door Side Hung Two Rebated Shutters With Plywood(6Mm) & Laminated (1Mm) On Both Sides And All Accessories ( Ss Hinges (4 Nos), Tower Bolt , Ss Handles Etc..) , Lead Lined Door Frames: Lead(2Mm) Lined Flush Door Side Hung Single Shutter With Plywood(6Mm) &Laminated (1Mm) On Both Sides And All Accessories(Lead Sheet Should Overlap Door Frame & Wall )Includingproviding Wood Work In Frames Of Doors And Fixed In Position With Hold Fast Lugs Or With Dash Fasteners Of Required Dia & Length , Using Good Quality Anjili Wood /Jack Wood (Frame Size 12 Cm X 8 Cm) , Wood Frame For Fixing Lead Glass (Lead Sheet Should Overlap Door Frame & Wall ) , Steel Cupboard (Godrej) For Storage 6Ft Tall 3 Feet Width , Providing And Fixing 2.0Mm Th. Vinyl Floor With Rubber Based Adhesive Over Clean And Smooth Surface Including Finishing By Rolling A Light Roller All Complete. , Wiring For Twin Control Light Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Medium Class Pvc Conduit, 2 Way Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm. Frls Pvc Insulated Copper Conductor Single Core Cable Etc As Required. , Supplying And Fixing Call Bell/ Buzzer Suitable For Single Phase, 230 Volts, Complete As Required. , Wiring For Group Controlled (Looped) Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point ( Without Independent Switch Etc.) With 1.5 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface/ Recessed Pvc Conduit, And Earthing The Point With 1.5 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. Group B , Wiring For Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Medium Class Pvc Conduit, With Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm. Frls Pvc Insulated Copper Conductor Single Core Cable Etc As Required. Group C , Wiring For Circuit/ Submain Wiring Along With Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Medium Class Pvc Conduit As Required 2X1.5 Sq.Mm + 1X1.5 Sq.Mm Earth Wire , Wiring For Circuit/ Submain Wiring Along With Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Medium Class Pvc Conduit As Required 2X 2.5 Sq. Mm + 1 X 2.5Sq. Mm Earth Wire , Wiring For Circuit/ Submain Wiring Along With Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Medium Class Pvc Conduit As Required 2 X 4 Sq. Mm + 1 X 4Sq. Mm Earth Wire , Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel/ Pvc Conduit As Required.4 X 6 Sq. Mmm , Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel/ Pvc Conduit As Required. 3 X 1.5 Sq.Mm , Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel/ Pvc Conduit As Required.3 X 2.5Sq. Mmm , Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel/ Pvc Conduit As Required. 3 X 4 Sq. Mmm , Supplying And Drawing Following Pair 0.5 Mm Dia Frls Pvc Insulated Annealed Copper Conductor,Unarmored Telephone Cable In The Existing Surface/ Recessed Steel/ Pvc Conduit As Required.2 Pairs , Supplying And Drawing Co-Axial Tv Cable Rg-6 Grade, 0.7 Mm Solid Copper Conductor Pe Insulated, Shielded With Fine Tinned Copper Braid And Protected With Pvc Sheath In The Existing Surface/ Recessed Steel/ Pvc Conduit As Required. , Supplying And Fixing Of Following Sizes Of Medium Class Pvc Conduit Along With Accessories In Surface/ Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required.20Mm , Supplying And Fixing Of Following Sizes Of Medium Class Pvc Conduit Along With Accessories In Surface/ Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required.25Mm , Supplying And Drawn Of Utp 4 Pair Cat 6 Lan Cable In The Existing Surface/Recessed Steel/Pvc Conduit As Required1 Run Of Cable , Cat 6 Rj 45 Computer Jack Modular Socket Outlet , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required.5/6 Amp Switch , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. 2 Way 5/6 Amp Switch , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required.15/16 Amp Switch , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required.3 Pin 5/6 Amp Socket Outlet , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required.6 Pin 15/16 Amp Socket Outlet , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. Telephone Socket Outlet , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. Tv Antenna Socket Outlet , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required.Bell Push , Supplying And Fixing Modular Blanking Plate On The Existing Modular Plate & Switch Box Excluding Modular Plate As Required. , Supplying And Fixing Following Size/ Modules, Gi Box Along With Modular Base & Cover Plate For Modular Switches In Recess Etc As Required. 1 Or 2 Module (75Mmx75mm) , Supplying And Fixing Following Size/ Modules, Gi Box Along With Modular Base & Cover Plate For Modular Switches In Recess Etc As Required. 3 Module (100Mmx75mm) , Supplying And Fixing Following Size/ Modules, Gi Box Along With Modular Base & Cover Plate For Modular Switches In Recess Etc As Required. 6 Module (200Mmx75mm) , Supplying And Fixing Following Size/ Modules, Gi Box Along With Modular Base & Cover Plate For Modular Switches In Recess Etc As Required. 8 Module (125Mmx125mm) , Supplying And Fixing Call Bell/ Buzzer Suitable For Single Phase, 230 Volts, Complete As Required. , Extra For Fixing The Louvers/ Shutters Complete With Frame For An Exhaust Fan Of All Sizes , Charges For Cutting Holes Suitable For Accommodating Exhaust Fans Up To 305Mm Sweep Including Plastering Color Washing Etc. As Required. , Installation Of Exhaust Fan In The Existing Opening, Including Making Good The Damage Connection Testing, Commissioning Etc. As Required.Upto 450 Mm Sweep , Supply Of 300/305 Mm Sweep Light Duty Exhaust Fan In Metal Frame Working On230 Va/C , Supply And Installation Of Sheet Steel, Phosphatised And Painted, Dust And Vermin Proof Enclosure Of Mcb Db Including Copper /Brass Bus Bar, Neutral Link, Earth Bus And Din Rail Suitable For Fixing Mcb/ Isolator Etc. Fixed On Wall Using Suitable Anchor Bolts Or Fixed In Recess Including Cutting Hole On The Wall, Making Good The Damages, Color Washing Etc. As Required4 Way (8+12) - Three Phase Double Cover (Ip 42/43) , Supply And Installation Of Sheet Steel, Phosphatised And Painted, Dust And Vermin Proof Enclosure Of Mcb Db Including Copper /Brass Bus Bar, Neutral Link, Earth Bus And Din Rail Suitable For Fixing Mcb/ Isolator Etc. Fixed On Wall Using Suitable Anchor Bolts Or Fixed In Recess Including Cutting Hole On The Wall, Making Good The Damages, Color Washing Etc. As Required6 Way (8+18) - Three Phase Double Cover (Ip 42/43) , Supply And Installation Of Sheet Steel, Phosphatised And Painted, Dust And Vermin Proof Enclosure Of Mcb Db Including Copper /Brass Bus Bar, Neutral Link, Earth Bus And Din Rail Suitable For Fixing Mcb/ Isolator Etc. Fixed On Wall Using Suitable Anchor Bolts Or Fixed In Recess Including Cutting Hole On The Wall, Making Good The Damages, Color Washing Etc. As Required 4 Way (8+12) - Double Cover Tpn Vertical Db With Provision For Fixing Mccb As Incomer And Sp/ Tp Mcb As Outgoing (Ip 42/43) , Supply And Installation Of Sheet Steel, Phosphatised And Painted, Dust And Vermin Proof Enclosure Of Mcb Db Including Copper /Brass Bus Bar, Neutral Link, Earth Bus And Din Rail Suitable For Fixing Mcb/ Isolator Etc. Fixed On Wall Using Suitable Anchor Bolts Or Fixed In Recess Including Cutting Hole On The Wall, Making Good The Damages, Color Washing Etc. As Required 6 Way (8 + 18) - Double Cover Tpn Vertical Db With Provision For Fixing Mccb As Incomer And Sp/ Tp Mcb As Outgoing (Ip 42/43) , Supplying And Fixing Following Way Prewired Sp&N Mcb Distribution Board Of Steel Sheet For 240 Volts On Surface/ Recess Complete With Loose Wire Box, Terminal Connectors For All Incoming And Outgoing Circuits, Duly Prewired With Suitable Size Fr Pvc Insulated Copper Conductor Up To Terminal Blocks, Tinned Copper Bus Bar, Neutral Link, Earth Bar, Din Bar, Detachable Gland Plate, Interconnections, Powder Painted Including Earthing Etc. As Required. (But Without Mcb/ Rccb/Isolator)2+12 Way, Double Door , Supplying And Fixing Following Rating, Double Pole, 240 Volts, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 40 Amps , Supplying And Fixing Following Rating, Double Pole, (Single Phase And Neutral), 240 V, Residual Current Circuit Breaker (Rccb), Having A Sensitivity Current 30 Ma In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.40 Amps , Supplying And Fixing Following Rating, Four Pole, (Three Phaseand Neutral), 415 V, Residual Current Circuit Breaker (Rccb), Having A Sensitivity Current 30 Ma In The Existing Mcb Dbcomplete With Connections, Testing And Commissioning Etc. Asrequired. 63 A Rating, 4 Pole, 30 Ma Rccb , Supplying And Fixing Following Rating, Four Pole, (Three Phase And Neutral), 415 V, Residual Current Circuit Breaker (Rccb), Having A Sensitivity Current 30 Ma In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.40 A Rating, 4 Pole, 30 Ma Rccb , Supplying And Fixing Following Rating, Four Pole, 415 Volts, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 40 Amps , Supplying And Fixing Following Rating, Four Pole, 415 Volts, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 63 Amps , Supplying And Fixing 5 Amps To 32 Amps Rating, 240/415 Volts, C Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. Single Pole , Supplying And Fixing Following Rating, Three Pole, Mcb63 A Rating, 3 Pole, Mcb , Supplying And Fixing Following Rating, Three Pole, Mcb 40 A Rating, 3 Pole, Mcb , Providing And Fixing Following Rating And Breaking Capacity And Pole Mccb With Thermomagnetic Release And Terminal Spreaders In Existing Cubicle Panel Board Including Drilling Holes In Cubicle Panel, Making Connections, Etc. As Required100 Amp, 30 Ka 4 Pole , Providing And Fixing Following Rating And Breaking Capacity And Pole Mccb With Thermomagnetic Release And Terminal Spreaders In Existing Cubicle Panel Board Including Drilling Holes In Cubicle Panel, Making Connections, Etc. As Required125amp, 36Ka , Supply, Conveyance And Fixing The Following Types & Current Rated Control Gears & Switchgears Conforming To Is 13947 Suitable For 440 V, 50 Hz, Ac Supply In The Existing Panel Assembly As Required. 16A -100A, 35/36 Ka (Ics=100%Icu), 4 Pole, Current Limiting Type Mccb With Microprocessor Based Release With Overload Setting Of 50 - 100% Having Adjustable Ol & Sc , Laying And Fixing Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Following Size On Cable Tray As Required. Above 35 Sq. Mm And Upto 95 Sq. Mm (Clamped With 25X3mm Ms Flat Clamp) , Supply, Laying And Clamping Of 1 No. Pvc Insulated And Pvc Sheathed Armored Aluminum Power Cable, 1.1 Kv Grade Of The Following Sizes Using Clamps Noted Along With The Cables, Spacing Of Clamps Not Exceeding 60Cms, Making Good The Damages, Color Washing Etc. As Required.4 Core 185 Sq Mm , Supply, Laying And Clamping Of 1 No. Pvc Insulated And Pvc Sheathed Armored Aluminum Power Cable, 1.1 Kv Grade Of The Following Sizes Using Clamps Noted Along With The Cables, Spacing Of Clamps Not Exceeding 60Cms, Making Good The Damages, Color Washing Etc. As Required. 4 Core 240 Sq Mm , Supply, Laying And Clamping Of 1 No. Pvc Insulated And Pvc Sheathed Armored Copper Power Cable, 1.1 Kv Grade Of The Following Sizes Using Clamps Noted Along With The Cables, Spacing Of Clamps Not Exceeding 60Cms, Making Good The Damages, Color Washing Etc. As Required. 3.5 Core 25 Sq Mm With Factory Made Clamp , Supply, Laying And Clamping Of 1 No. Pvc Insulated And Pvc Sheathed Armored Copper Power Cable, 1.1 Kv Grade Of The Following Sizes Using Clamps Noted Along With The Cables, Spacing Of Clamps Not Exceeding 60Cms, Making Good The Damages, Color Washing Etc. As Required. 3.5 Core 50 Sq Mm With Factory Made Clamp , Supply, Laying And Clamping Of 1 No. Pvc Insulated And Pvc Sheathed Armored Copper Power Cable, 1.1 Kv Grade Of The Following Sizes Using Clamps Noted Along With The Cables, Spacing Of Clamps Not Exceeding 60Cms, Making Good The Damages, Color Washing Etc. As Required. 4 Core 10 Sq Mm With Factory Made Clamp , Supply, Laying And Clamping Of 1 No. Pvc Insulated And Pvc Sheathed Armored Copper Power Cable, 1.1 Kv Grade Of The Following Sizes Using Clamps Noted Along With The Cables, Spacing Of Clamps Not Exceeding 60Cms, Making Good The Damages, Color Washing Etc. As Required.4 Core 16 Sq Mm With Factory Made Clamp , Supply & Laying Of One No. Pvc Insulated And Pvc Sheathed Armored Copper Power Cable Of 1.1 Kv Grade Of The Following Sizes In The Existing Masonry Open Duct As Required.3.5 Core 95 Sq Mm , Supply, Laying And Clamping Of 1 No. Pvc Insulated And Pvc Sheathed Armored Copper Power Cable, 1.1 Kv Grade Of The Following Sizes Using Clamps Noted Along With The Cables, Spacing Of Clamps Not Exceeding 60Cms, Making Good The Damages, Color Washing Etc. As Required. 3.5 Core 95 Sq Mm , Supply, Laying And Clamping Of 1 No. Pvc Insulated And Pvc Sheathed Armored Copper Power Cable, 1.1 Kv Grade Of The Following Sizes Using Clamps Noted Along With The Cables, Spacing Of Clamps Not Exceeding 60Cms, Making Good The Damages, Color Washing Etc. As Required.4 Core 70 Sq Mm , Supply & Laying Of One No. Pvc Insulated And Pvc Sheathed Armoured Aluminum Power Cable Of 1.1 Kv Grade Of The Following Sizes In The Existing Masonry Open Duct As Required.3.5 Core 70 Sq Mm , Supplying And Installing Following Size Of Perforated Painted With Powder Coating Ms Cable Trays With Perforation Not More Than 17.5%, In Convenient Sections, Joined With Connectors, Suspended From The Ceiling With Ms Suspenders Including Bolts & Nuts, Painting Suspenders Etc As Required.225Mm Width X 50Mm Depth X 1.6Mm Thickness , Supplying And Installing Following Size Of Perforated Painted With Powder Coating Ms Cable Trays Bends With Perforation Not More Than 17.5%,, Joined With Connectors, Suspended From The Ceiling With Ms Suspenders Including Bolts & Nuts, Painting Suspenders Etcas Required 225 Mm Width X50 Mm Depth X 1.6 Mm Thickness , Supplying Siemens / Tropodur Type Nickel Plated Double Compression Brass Cable Gland For Pvc Insulated And Pvc Sheathed Armoured Aluminium/ Copper Conductor Cable 1.1 Kv Grade, And Making End Termination Suitable For 2/ 3/ 3½/ 4 Core Cable Of The Following Sizes As Required. 50 Sqmm , Supplying And Making End Termination With Brass Compression Gland And Aluminum Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminum Conductor Cable Of 1.1 Kv Grade As Required. 3 1/2X 70 Sq. Mm (38Mm) , Supplying And Making End Termination With Brass Compression Gland And Aluminum Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminum Conductor Cable Of 1.1 Kv Grade As Required.3 1/2X 95 Sq. Mm (45Mm) , Supplying And Making End Termination With Brass Compression Gland And Aluminum Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminum Conductor Cable Of 1.1 Kv Grade As Required.3 1/2X 185 Sq. Mm (57Mm) , Supplying And Making End Termination With Brass Compression Gland And Aluminum Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminum Conductor Cable Of 1.1 Kv Grade As Required.3 1/2X 240 Sq. Mm (62Mm) , Supplying And Making End Termination With Brass Compression Gland And Aluminum Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminum Conductor Cable Of 1.1 Kv Grade As Required.4 X 10 Sq. Mm (25Mm) , Supplying And Making End Termination With Brass Compression Gland And Aluminum Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminum Conductor Cable Of 1.1 Kv Grade As Required.4 X 16 Sq. Mm (28Mm) , Supplying And Making End Termination With Brass Compression Gland And Aluminum Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminum Conductor Cable Of 1.1 Kv Grade As Required. 4 X 25 Sq. Mm (28Mm) , Supplying And Making End Termination With Brass Compression Gland And Aluminum Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminum Conductor Cable Of 1.1 Kv Grade As Required. 4 X 50 Sq. Mm (35Mm) , Supplying Siemens / Tropodur Type Nickel Plated Double Compression Brass Cable Gland For Pvc Insulated And Pvc Sheathed Armoured Aluminium/ Copper Conductor Cable 1.1 Kv Grade, And Making End Termination Suitable For 2/ 3/ 3½/ 4 Core Cable Of The Following Sizes As Required. 16 Sq.M , Supplying Siemens / Tropodur Type Nickel Plated Double Compression Brass Cable Gland For Pvc Insulated And Pvc Sheathed Armoured Aluminium/ Copper Conductor Cable 1.1 Kv Grade, And Making End Termination Suitable For 2/ 3/ 3½/ 4 Core Cable Of The Following Sizes As Required.25 Sqmm , Supplying Siemens / Tropodur Type Nickel Plated Double Compression Brass Cable Gland For Pvc Insulated And Pvc Sheathed Armoured Aluminium/ Copper Conductor Cable 1.1 Kv Grade, And Making End Termination Suitable For 2/ 3/ 3½/ 4 Core Cable Of The Following Sizes As Required.10 Sqmm , Supplying Siemens / Tropodur Type Nickel Plated Double Compression Brass Cable Gland For Pvc Insulated And Pvc Sheathed Armoured Aluminium/ Copper Conductor Cable 1.1 Kv Grade, And Making End Termination Suitable For 2/ 3/ 3½/ 4 Core Cable Of The Following Sizes As Required. 35 Sqmm , Supply Of Superior Quality Copper Tubular Cable Socket And Making Core Termination Of Cables Of The Following Sizes Including Crimping Etc. As Required. 50 Sqmm , Supply Of Superior Quality Copper Tubular Cable Socket And Making Core Termination Of Cables Of The Following Sizes Including Crimping Etc. As Required. 35 Sqmm , Supply Of Superior Quality Copper Tubular Cable Socket And Making Core Termination Of Cables Of The Following Sizes Including Crimping Etc. As Required.25 Sqmm , Supply Of Superior Quality Copper Tubular Cable Socket And Making Core Termination Of Cables Of The Following Sizes Including Crimping Etc. As Required.16 Sq.M , Supply Of Superior Quality Copper Tubular Cable Socket And Making Core Termination Of Cables Of The Following Sizes Including Crimping Etc. As Required.10 Sqmm , Supplying And Providing Earth Clamps For Siemens/ Tropodur Type Cable Glands Of Suitable Length And Other Dimensions Noted Along With Each Size Of Glands For The Following Sizes Of Cables As Required.25Sq - 95Sq Mm With 20 Mm Wide X 1.20 Mm Thick Clip , Supplying And Providing Earth Clamps For Siemens/ Tropodur Type Cable Glands Of Suitable Length And Other Dimensions Noted Along With Each Size Of Glands For The Following Sizes Of Cables As Required. 4Sqmm-16 Sq Mm With 12 Mm Wide X 1 Mm Thick Clip , Supply And Drawing Bare Earthing Conductors Of The Following Sizes Along With Wiring/ Cables And Giving Connection As Required2.65 Mm Copper Conductor (12 Swg) , Supply And Drawing Bare Earthing Conductors Of The Following Sizes Along With Wiring/ Cables And Giving Connection As Required3.15 Mm Copper Conductor ( 10 Swg) , Supply And Drawing Bare Earthing Conductors Of The Following Sizes Along With Wiring/ Cables And Giving Connection As Required4.00 Mm Copper Conductor ( 8 Swg) , Supply Of Superior Quality Copper Earth Socket For The Following Size Of Earth Conductor Including Crimping Etc. As Required.2.65 Mm (12 Swg) , Supply Of Superior Quality Copper Earth Socket For The Following Size Of Earth Conductor Including Crimping Etc. As Required. 3.15 Mm (10 Swg) , Supply Of Superior Quality Copper Earth Socket For The Following Size Of Earth Conductor Including Crimping Etc. As Required. 4.00 Mm (8 Swg) , Earthing With Copper Earth Plate 600 Mm X 600 Mm X 3 Mm Thick Including Accessories, And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Of 2.7 Meter Long Etc. With Charcoal/ Coke And Salt As Required. , Supply And Clamping The Following Size Of Strips On Surface Of Wall/ Parapet/ Existing Cable Tray Using Clamps Fabricated From 20 X 3 Mm Gi Flat Duly Painted Or Heavy Duty Gi Spacer Saddles Spacing Of Clamps Not Exceeding 1 M, Making Good The Damages, Color Washing Etc. As Required (For Horizontal Run) 25 X 3 Mm Copper Strip , Supplying, Threading, Laying And Jointing Of The Following Sizes Of B Class Gi Pipe With All Required Accessories In Ground In Trench As Protective Covering To Earth Leads40mm Dia , Supplying And Laying 25 Mm X 5 Mm Copper Strip At 0.50 Meter Below Ground As Strip Earth Electrode, Including Connection/ Terminating With Nut, Bolt, Spring, Washer Etc. As Required. (Jointing Shall Be Done By Overlapping And With 2 Sets Of Brass Nut Bolt & Spring Washer Spaced At 50Mm) , Providing And Fixing 25 Mm X 5 Mm Copper Strip On Surface Or In Recess For Connections Etc. As Required. , Supply And Drawing Bare Earthing Conductors Of The Following Sizes Along With Wiring/ Cables And Giving Connection As Required2.00 Mm Copper Conductor ( 14 Swg) , Supply Conveyance, Installation, Testing And Commissioning The Light Fittings Of Following Types Made From Crca Sheet 0.5Mm Thickness With All Accessories And Lamps Directly On Wall And Giving Connections With 16/0.20 Mm 3 Core Pvc Insulated And Sheathed Round Copper Conductor Flex Wire Or Extending The Original Wiring And Giving Connections As Required 1200 Mm 1X20w Led Lamp With Box Type Fixture , Supply & Installation Of Light Fittings On Tw Round Block
Supply, Conveyance Installation Testing And Commissioning The Light Fittings Of Following Types Made Of Crca With 0.5Mm Thickness Complete With All Accessories And Lamps Etc. Directly On Wall Or Ceiling With Pvc Round Block Neatly Painted To Suit The Fitting And Giving Connection With Required Length Of 16/0.20Mm 3 Core Copper Conductor Flex Wire Conforming To Relevant Iss And Giving Connections As Required.1200Mm 1X20w Led Lamp With Box Type Fixture , Recess Mounted Led Luminaire With Full Diffuser Type Upto 36 W (Max), 2X2 Led, Cool White, 5700K, White Powder Coated Crca Housing, Wipro Crco10r038hp57gl1 Or Bajaj Bzrsql 36W Gzi Cw Or Equivalent , Frame For Fixing Recess Mounted Led 2X2 Ft Luminaire 608 Mm X 608 Mm , Recess Mounted Circular Led Retrofit Downlighter, 15W, Powder Coated White Finish, Bpslr 15W Wh Bajaj Or Equivalent , Supplying And Fixing Of 6 / 7 W Pin Type Led Bulb In The Existing Angle Batten Etc As Required (Philips, Wipro Or Similar Superior Make) , Sitc Of 400Mm Sweep Meduim Duty Wall Fans With Metallic Vanes (Make: M/S Almonard/ Crompton/Bajaj Or Equivalent) , Abc Powder Type Fire Extinguisher With Nabl Approval, Fights Class A, B, C And Electrically Started Fires. , Fire Extinguisher Carbon Di-Oxide Type With Nabl Approval , Charges For Dismantling The Existing Electrical Installations Complete Making Good The Damages Of The Wall And Conveying The Dismantled Materials To Store Etc As Required. , Numbering Of Ceiling Fan / Exhaust Fan/ Fluorescent Fittings As Required. , Copper Pipe With Superlon Insulation For Suction And Discharge , Pvc Drain Pipe With Proper Insulation , Weather Proof 3 Core Copper Wire For Indoor To Outdoor Connecting Cable (Size As Per The Requirement Of Ac Manufacturer) , Core Cutting Charges Including Making The Surface Finished With Plastering And Painting, Making Good And Finishing With Matching Surface After Housing Pipe Etc. , Supporting Stand For Fixing Outdoor Unit(Powder Coated) , 4 Kva Voltage Stabilizer Wall Mount Type With Time Delay, High& Low Voltage& Thermal Overload Protection, Input Voltage: 170-220V, Output Voltage : 200-240V, High Voltage Cut Off : 240V, Efficiency: >95%, Frequency : 50Hz, V Guard Vg 500 Or Equivalent , Supply, Conveyance Testing And Commissioning Of 2 Ton 5 Star Inverter Type, Split Ac Unit With Copper Tube Cooling Coils, 5 Star Rating Bluestar/Lg(Dual Inverter Type)/Voltas/Mitsubishi Or Superior Superior Brands, Cooling Capacity 6000 Kw/Hr With Rotary/Scroll Type Compressors. With Microprocessor Controlled Code Less Remote, Cfm Above 500/450, Led/Lcd Display , Supply, Conveyance Testing And Commissioning Of 1 Ton 5 Star Inverter Type, Split Ac Unit With Copper Tube Cooling Coils, 5 Star Rating Bluestar/Lg(Dual Inverter Type)/Voltas/Mitsubishi Or Superior Brands, Cooling Capacity 3000 Kw/Hr With Rotary /Scroll Type Compressors. With Microprocessor Controlled Code Less Remote, Cfm Above 500/450, Led/Lcd Display , Sitc Of 19 Mm Thick Nitrile Rubber For Under Deckinsulation , Charges For Cutting Holes Suitable For Accommodating The Supply Ducts Including Plastering, Color Washing Etc. As Required. , Outdoor Unit Stand With Ribbed Rubber Pads , Electrical Cabling Between Indoor And Outdoor Units, With Required Size Cables/Wires(Havells/Rr Kabel/V-Guard Frls Wires) , Supply, Installation, Testing And Commissioning Upvc Drain Pipe 6Kg/Sq.Cmof Suitable Dia Connecting The Drain Pan Of The Indoor Units To Nearest Drain Point, With 12Mm Thick Closed Cell Elastomeric Insulation As Per Specification , Motorized Volume Control Damper For Individual Operation Of Ductable Split Air Conditioners , Supply And Fixing Of Canvas Connection And Ribbed Rubber Pads As Vibration Isolators , Providing And Fixing Of Thermal Insulation Lining With 13Mm Thick Nitrile Rubber Closed Cell Type With Adhesive, On Supply Duct. , Providing And Fixing Of Acoustic Duct Lining With 10Mm Thick Nitrile Rubber Open Cell Type Inside The Ducts , Supply, Installation, Testing And Commissioning Of Powder Coated Extruded Aluminum Continuous Grilles 150Mm High For Return Air As Per Spec , Supply, Installation, Testing And Commissioning Of Powder Coated Extruded Aluminimum Continuous Grilles 150 Mm High For Supply Air With Aluminum Damper As Per Spec , Supply, Installation, Testing And Commissioning Of Volume Control Duct Damper Made Of Extruded Aluminum For Ducts/Collars To Be Provided With Suitable Links, Lebers And Quadrants For Manual Control Of Volume Of Air Flow And For Proper Balancing Of The Air Distribution In The Main Duct Complete With Neoprene Rubber Gaskets, Nuts, Bolts, Screws Linkages, Flanges Etc., As Per Specifications. , Supply, Installation, Testing And Commissioning Of Gss Sheet Metal Ducting For Air Distribution Network From Indoor Unit As Per Ducting Specifications Complete With Angle Flanges ,Supports, Gi Rods , Anchor Bolts ,Gi Nuts And Bolts, Pvc/ Rubber Gaskets Complete With All Fittings , Bends, Transformations, Vanes, Splitter Dampers, Inspection Doors, Plenums, Channels, Rods, Anchor Bolts, Etc To Roof /Truss As Per Is 655. The Job Includes Entire Air Distribution Network And Sizing Of Ducts Also. Thickness: 24G , Supply, Installation, Testing And Commissioning Of Gss Sheet Metal Ducting For Air Distribution Network From Indoor Unit As Per Ducting Specifications Complete With Angle Flanges ,Supports, Gi Rods , Anchor Bolts ,Gi Nuts And Bolts, Pvc/ Rubber Gaskets Complete With All Fittings , Bends, Transformations, Vanes, Splitter Dampers, Inspection Doors, Plenums, Channels, Rods, Anchor Bolts, Etc To Roof /Truss As Per Is 655. The Job Includes Entire Air Distribution Network And Sizing Of Ducts Also. Thickness: 22G , Supply, Installation, Testing And Commissioning (Sitc) Of 8.75 Tr X 2 Nos Or Higher Capacity Air Cooled Ductable Split Air Conditioner With Ceiling Suspended Idu And All Standard Fittings, Idu Ss Drain Pan, As Per Specifications Complete With Suitable Capacity Drive Motor, Air Cooled Condenser With All Accessories, Hermetically Sealed Scroll Compressor, Electronic Microprocessor Pendant Controller With Digital Display, First Charge Refrigerant Gas, Vibration Isolator Pads, Structural Supports For Fixing Idu/Odu As Shown In The Drawing, Safety Devices Including Thermal Protector, Pressure Relief Valve , Over Load Relays Single Phase Preventer Etc, Power Wiring(Max 3M From Isolator) And Control Cabling(Indoor To Outdoor),Thermostat Wiring, High-Low Pressure Cut Out,Suitable For Three Phase 440V Supply Etc Complete As Required , Supply And Providing Copper Earth Bus In The Panel Board , Supply Of Lt Switch Board Cubicle Type, Made Out Of 2 Mm Thick Crca Sheet, Totally Enclosed, Ip42, Free Standing, Wall/Floor Mounting, Dust And Vermin Proof, Powder Coated, Indoor, Compartmentalized, Suitable For Operation On 3 Phase And Neutral , 415 V, 50Hz Ac System With Bus-Bars Extendable On Both Sides, Including All The Necessary Internal Wiring , Suitable Spreader Etc. The Panel Shall Be Fabricated From A Firm Having Cpri Certification With Test Certificates For Similar Panel(Required For Short Circuit Rating, Temperature Rise And Ip Classification) And With Following Switchgears, Metering Instruments And Accessories Etc. Complete As Required As Per Drawing & Specification. Ryb Indicating Lamps Led Type 4A Sp Mcb (0-500)V Class 1 With 90 Deg Defl. Scale (0-200)A Class 1 With 90 Deg Defl. Scale, Voltmeter Selector Switch 200/5 A 5 Va Class .5S Cts On/Off Indication Lamp, Digital Multi-Function Meter To Read V,A.Hz,Pf,Kwh, Incomer 200A Fp Molded Case Circuit Breaker With Thermal Release With Ol And Sc Protection Neutral Link (Ics =100%Icu= 25Ka) -1 Nos Out Goings 160 A Fp Molded Case Circuit Breaker With Thermal Release With Ol And Sc Protection Neutral Link (Ics =100%Icu= 25Ka) - 1 Nos 125 A Fp Molded Case Circuit Breaker With Thermal Release With Ol And Sc Protection Neutral Link (Ics =100%Icu= 25Ka) - 2 Nos 100 A Fp Molded Case Circuit Breaker With Thermal Release With Ol And Sc Protection Neutral Link (Ics =100%Icu= 25Ka) - 2 Nos.The Panel Shall Be Top Entry/Exit And Suitable For Termination Of Cable System As Per Sld And Technical Specifications.Pn Busbar Chamber With Copper Busbar. , Supply Of Lt Switch Board Cubicle Type, Made Out Of 2 Mm Thick Crca Sheet, Totally Enclosed, Ip42, Free Standing, Wall/Floor Mounting, Dust And Vermin Proof, Powder Coated, Indoor, Compartmentalized, Suitable For Operation On 3 Phase And Neutral , 415 V, 50Hz Ac System With Bus-Bars Extendable On Both Sides, Including All The Necessary Internal Wiring , Suitable Spreader Etc. The Panel Shall Be Fabricated From A Firm Having Cpri Certification With Test Certificates For Similar Panel(Required For Short Circuit Rating, Temperature Rise And Ip Classification) And With Following Switch Gears, Metering Instruments And Accessories Etc. Complete As Required As Per Drawing & Specification. Ryb Indicating Lamps Led Type Digital Multi-Function Meter To Read V,A.Hz,Pf,Kwh Incomer 160A Fp Molded Case Circuit Breaker With Thermal Release With Ol And Sc Protection Neutral Link (Ics =100%Icu= 25Ka) -1 Nos 160A Copper Tpn Busbar Chamber With Copper Busbar. Out Goings 125A Fp Molded Case Circuit Breaker With Thermal Release With Ol And Sc Protection Neutral Link (Ics =100%Icu= 25Ka) - 1 Nos %Icu= 25Ka) - 2 Nos 63A Fp Mccb - 3 Nos The Panel Shall Be Top Entry/Exit And Suitable For Termination Of Cable System As Per Sld And Technical Specification. , Supply, Conveyance And Fixing The Following Types & Current Rated Control Gears & Switchgears Conforming To Is 13947 Suitable For 440 V, 50 Hz, Ac Supply In The Panel Assembly Made Out Of 1.6Mm Crca Powder Coated Sheet As Required. 320A/400A, 50/55 Ka (Ics=100%Icu), 4 Pole, Current Limiting Type Mccb With Microprocessor Based Release With Overload Setting Of 50 - 100% Having Adjustable Ol & Sc , Suitable De- Humidifier Units : Extraction At Least 35 Litres/Day, Compresor : Rotary, Air Flow : At Least 220M3/Hr, Reputed Brand, Input 230Vac , Charges For Obtaining Electrical Inspectorates Approval Including Scheme Apporval And Final Approval And Regularizing With Kseb , 24-Port Gigabit Manageable Smart Network Switch With 2 Sfps. Rack Mountable , Patch Panel - 24-Port Patch Panel With Cable Tray. Rack Mountable , 4U Rack- Wall Mountable Including 4X 6Amp Power Distribution Box , Supply Of Branded 1Mtr Patch Cords With Cat 6 Cable. , Supply Of Branded 2Mtr Patch Cords With Cat 6 Cable. , Supply Of Branded 3Mtr Patch Cords With Cat 6 Cable. , Supply Of Lt Switch Board Cubicle Type, Made Out Of 2 Mm Thick Crca Sheet, Totally Enclosed, Ip42, Free Standing, Wall/Floor Mounting, Dust And Vermin Proof, Powder Coated, Indoor, Compartmentalised, Suitable For Operation On 3 Phase And Neutral , 415 V, 50Hz Ac System With Busbars Extendable On Both Sides, Including All The Necessary Internal Wiring , Suitable Spreader Etc. The Panel Shall Be Fabricated From A Firm Having Cpri Certification With Test Certificates For Similar Panel(Required For Short Circuit Rating, Temperature Rise And Ip Classification) And With Following Switchgears, Metering Instruments And Accessories Etc. Complete As Required As Per Drawing & Specification. Ryb Indicating Lamps Led Type 4A Sp Mcb (0-500)V Class 1 With 90 Deg Defl. Scale. (0-200)A Class 1 With 90 Deg Defl. Scale Voltmeter Selector Switch 200/5 A 5 Va Class .5S Cts On/Off Indication Lamp Digital Multifunction Meter To Read V,A.Hz,Pf,Kwh Surge Protection Device (Type1+2) Incomer 400A Fp Molded Case Circuit Breaker With Micro Processor Based Release With Ol And Sc Protection Neutral Link (Ics =100%Icu= 25Ka) -1 Nos 200A Copper Tpn Busbar Chamber With Copper Busbar Out Goings 250A Fp Molded Case Circuit Breaker With Micro Processor Based Release With Ol And Sc Protection Neutral Link (Ics =100%Icu= 25Ka) -1 Nos 160A Fp Molded Case Circuit Breaker With Micro Processor Based Release With Ol And Sc Protection Neutral Link (Ics =100%Icu= 25Ka) -1 Nos 100 A Fp Mccb Isolator-2Nos 63 A Fp Mccb Isolator-2Nos The Panel Shall Be Top Entry/Exit And Suitable For Termination Of Cable System As Per Sld And Technical Specification (Not Taken For Evaluation) , Supply Of Lt Switch Board Cubicle Type, Made Out Of 2 Mm Thick Crca Sheet, Totally Enclosed, Ip42, Free Standing, Wall/Floor Mounting, Dust And Vermin Proof, Powder Coated, Indoor, Compartmentalized, Suitable For Operation On 3 Phase And Neutral , 415 V, 50Hz Ac System With Bus-Bars Extendable On Both Sides, Including All The Necessary Internal Wiring , Suitable Spreader Etc. The Panel Shall Be Fabricated From A Firm Having Cpri Certification With Test Certificates For Similar Panel(Required For Short Circuit Rating, Temperature Rise And Ip Classification) And With Following Switchgears, Metering Instruments And Accessories Etc. Complete As Required As Per Drawing & Specification. 4A Sp Mcb (0-500)V Class 1 With 90 Deg Defl. Scale. (0-200)A Class 1 With 90 Deg Defl. Scale, Voltmeter Selector Switch 200/5 A 5 Va Class .5S Cts On/Off Indication Lamp, Digital Multi-Function Meter To Read V,A.Hz,Pf,Kwh Incomer 250A Fp Molded Case Circuit Breaker With Thermal Release With Ol And Sc Protection Neutral Link (Ics =100%Icu= 25Ka) -1 Nos 250A Copper Tpn Busbar Chamber With Copper Busbar. Out Goings 200 A Fp Molded Case Circuit Breaker With Thermal Release With Ol And Sc Protection Neutral Link (Ics =100%Icu= 25Ka) - 1 Nos 125 A Fp Molded Case Circuit Breaker With Thermal Release With Ol And Sc Protection Neutral Link (Ics =100%Icu= 25Ka) - 1 Nos. 100 A Fp Molded Case Circuit Breaker With Thermal Release With Ol And Sc Protection Neutral Link (Ics =100%Icu= 25Ka) - 2 Nos. 63 A Fp Molded Case Circuit Breaker - 2 Nos.The Panel Shall Be Top Entry/Exit And Suitable For Termination Of Cable System As Per Sld And Technical Specification (Not Taken For Evaluation) , Supply, Installation, Testing And Commissioning (Sitc) Of 11 Tr X 2 Nos Or Higher Capacity Air Cooled Ductable Split Air Conditioner With Ceiling Suspended Idu And All Standard Fittings, Idu Ss Drain Pan, As Per Specifications Complete With Suitable Capacity Drive Motor, Air Cooled Condenser With All Accessories, Hermetically Sealed Scroll Compressor, Electronic Microprocessor Pendant Controller With Digital Display, First Charge Refrigerant Gas, Vibration Isolator Pads, Structural Supports For Fixing Idu/Odu As Shown In The Drawing, Safety Devices Including Thermal Protector, Pressure Relief Valve , Over Load Relays Single Phase Preventer Etc, Power Wiring(Max 3M From Isolator) And Control Cabling(Indoor To Outdoor),Thermostat Wiring, High-Low Pressure Cut Out,Suitable For Three Phase 440V Supply Etc Complete As Required (Not Taken For Evaluation)
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 1
19.
Heavy Industries and Public Enterprises #10390733 AOC
Vertical Extension & Other Development Works at Academic Block Annex-2 Palayad Campus, Kannur University, Kannur, Kerala under PM-USHA scheme- 1 Civil work -General Structural work 2 Chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual Chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of Engineer-In-Charge25 mm average thickness 3 Cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per direction of Engineer-In-Charge.Bars upto 12 mm diameter 4 Demolishing R.C.C. work manually / by mechanical means including stacking of steel bars and disposal of unserviceable material with in 50 metres lead as per direction of Engineer -in-Charge. 5 Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge.In cement mortar 6 Core Cutting of RCC slabs(12cm Maxi.thickness) by using mechanical core cutting equipment of required diameter of the pipe in full depth etc to the satisfaction of engineer in charge including all cost and conveyance materials and labours charge etc complete (dia 80-200mm) 7 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil 8 Extra for cutting reinforcement bars manually/ by mechanical means in R.C.C. or R.B. work ( Payment shall be made on the cross sectional area of R.C.C. or R.B work) as per direction of Engineer-in-charge. 9 Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil. and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within alead of 50 m:Pipes, cables etc. exceeding 80 mm dia but not exceeding 300 mm dia 10 Excavation work by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50 m.Ordinary rock 11 Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. 12 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size) 13 Providing and laying cement concrete in retaining walls, return walls, walls ( any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts,buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor, etc. up to floor five level, excluding the cost of centering, shuttering and finishing:1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) 14 Making plinth protection 50 mm thick of cement concrete 1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75 mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the top smooth. 15 Providing and laying in position machine batched and machine mixed design mix M- 25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to siteof laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work above plinth level upto floor V level 16 Extra for providing richer mixes at all floor levels. Note:- Excess/less cement over the specified cement content used is payable/ recoverable separately.Providing M-30 grade concrete instead of M-25 grade BMC/RMC. (Note:- Cement content considered in M-30 is @ 340 kg/cum). 17 Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. 18 Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform 19 Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers 20 Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts 21 Centering and shuttering including strutting, etc. and removal of form for:Stairs, (excluding landings ) except spiral - staircases) 22 Centering and shuttering including strutting, etc. and removal of form for:Weather shade, Chajjas, corbels etc., including edges 23 Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders, bressumers and cantilevers with water proof ply 12 mm thick. 24 Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo - Mechanically Treated bars of grade Fe-500D or more 25 Block work & Finishing Work 26 Laterate masonry with neatly dressed laterate stone of size 40x20x15cm or nearest size in cement mortar 1:6 for super structure above plinth level up to floor two level including all cost of materials, labour charges etc. 27 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) 28 6 mm cement plaster of mix:1:3 ( 1 cement : 3 fine sand) 29 Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer 30 12 mm cement plaster finished with a floating coat of neat cement of mix:1:3 ( 1 cement : 3 fine sand) 31 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 32 Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile including applying additional coats wherever required to achieve even shade and colour.Two coats 33 Finishing walls with Acrylic Smooth exterior paint of required shade:New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) 34 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work 35 Add for plaster drip course / groove in plastered surface or moulding to R.C.C. projections. 36 Teracotta Clay Jali work, For Building work, minimum 7.5 cm thick as per approved design and pattern of Engineer in charge in super structure above plinth level upto floor V level with cement mortar 1:4 (1 cement : 4 coarse sand) with neat finish, polishing work all complete. 37 Providing and fixing partition upto ceiling height consisting of G.I. frame and required board, including providing and fixing of frame work made of special section power pressed/ roll form G.I. sheet with Zinc coating of 120 gms/ (both side inclusive), consisting of floor and ceiling channel 50 mm wide having equal flanges of 32 mm and 0.50 mm thick, fixed to the floor and ceiling at the spacing of 610 mm centre to centre with dash fastener of 12.5 mm dia meter 50 mm length or suitable anchor fastener or metal screws with nylon plugs and the studs 48 mm wide having one flange of 34 mm and other flange 36 mm and 0.50 mm thick fixed vertically within flanges of floor and ceiling channel and placed at a spacing of 610 mm centre to centre by 6 mm dia bolts and nuts, including fixing of studs along both ends of partition fixed flush to wallwith suitable anchor fastener or metal screws with nylon plugs at spacing of 450 mm centre to centre, and fixing of boards to both side of frame work by 25 mm long dry wall screws on studs, floor and ceiling channels at the spacing of 300 mm centre to centre.The boards are to be fixed to the frame work with joints staggered to avoid through cracks, M.S. fixing channelof 99 mm width (0.9 mm thick having two flanges of 9.5 mm each) to be provided at the horizontal joints of two boards, fixed to the studs using metal to metal flat head screws, including jointing and finishing to a flush finish with recommended jointing compound, jointing tape, angle beads at corners (25 mm x 25 mm x0.5 mm), joint finisher and two coats of primer suitable for board as per manufactures specification and direction of engineer in charge all complete.75 mm overall thickness partition with 12.5 mm thick double skin fire rated Glass Reinforced Gypsum (GRG),plaster board conforming to IS : 2095 : (part 3) 1996 (Board with BIS Certification marks) 38 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions,i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately):For fixed portionPowder coated aluminium (minimum thickness of powder coating 50 micron) 39 For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately)Powder coated aluminium (minimum thickness of powder coating 50 micron) 40 Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS : 12823 Grade I Type II, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of Engineer - in- Charge.Pre- laminated particle board with decorative lamination on both sides 41 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness 42 Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete:125 mm 43 Providing and fixing bright finished 100 mm mortice lock with 6 levers without pair of handles of approved quality for aluminium door, with necessary screws etc complete as per direction of Engineer- in- charge. 44 Providing and fixing aluminium tower bolts, ISI marked, anodised(anodic coating not less than grade AC 10 as per : 1868), transparent or dyed to required colour or shade, with necessary screws complete:300x10 mm 45 Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. 46 Joinery 47 Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross- section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminated shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2 mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame. 48 Providing and fixing to existing door frames.30 mm thick Fiberglass Reinforced Plastic (F.R.P) flush door shutter in different plain and wood finish made with fire retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate all around, with suitable wooden blocks inside at required places for fixing of fittings and polyurethane foam (PUF) / Polystyrene foam to be used all filler material throughout the hollow panel, casted monoolithically with testing parameters of F.R.P. laminate conforming to table - 3 of IS : 14856, complete as per direction of Engineer- in-charge. 49 Providing and fixing factory made uPVC white colour casement/casement cum fixedglazedwindowscomprisingofuPVCmulti-chamberedframe,sashand mullion(whereeverrequired)extrudedprofilesduly reinforcedwith1.60+/- 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriatedimension,EPDMgasket,stainlesssteel(SS304grade)friction hinges, zinc alloy (white powder coated) casement handles, G.I fasteners 100 x 8 mmsizeforfixingframetofinishedwall,plasticpackers,plasticcapsand necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardwares and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately)Note: For uPVC frame, sash and mullion extruded profilesminus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable.Casement window double panels with S.S. friction hinges (350 x 19 x 1.9 mm) made of (big series) frame 67 x 60 mm & sash / mullion 67 x 80 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead/ double glazing bead of appropriate dimension. (Area of window above 1.50 sqm). 50 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5.50 mm thickness 51 Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately), using good quality Anjili wood /jack wood 52 Providing and fixing paneled and glazed shutters for doors, windows and clerestory windows, 35 mm thick shutters including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineerin - charge using Anjili/ Jack wood 53 Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to openings/ wooden frames with rawl plugs screws etc 54 Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embeddings in cement concrete block 30x10x15 cm 1:3:6 mix ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) 55 Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete:250x10 mm 56 Providing and fixing CP Brass Handle 450mm in all types of doors with the necessary fittings and arrangements all complete. 57 Providingand fixing chromium plated brass handles with necessary screws etc. complete:200 mm 58 Providing and fixing bright finished 100 mm mortice lock with 6 levers without pair of handles of approved quality, with necessary screws etc complete as per direction of Engineer- in- charge. 59 French spirit polishing:Two or more coats on new works including a coat of wood filler 60 Providing and fixing 1 mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer.Using flats 30x6 mm for diagonal braces and central cross piece 61 Fire Metal door. Material Specifications: Frame : GI 1.60 mm, Shutter : GI 1.20 mm, Shutter Width / Active Shutter Width : 808.00 mm, Frame Profile: 143.00 mm X 57.00 mm, Frame Profile type : Normal, Frame Rebate : Double, Door type : Single leaf door, Infill Material : Honey Comb, Vision Panel Active: 200 mmX300 mm. 8nos Ball bearing butt hinge, BB3090F, SS304, of size 100 x 75 x 3mm with screws in SSS , 1no Euro profile half cylinder 3005, 42mm Key x Blank, Silver satin finish , 2no Surface door closer TS73, size EN2/3/4, with standard arm, Silver finish, 1no Clear glass, 6mm of size 200 x 300mm, 2 nos concealed flush bolt, Mortise sash lock with lever handle on side and panic lever on other side. The door should have a minimum fire rating of 2hrs . Wall Opening Size 1800X2250 mm. 62 Fire Metal door. Material Specifications: Frame : GI 1.60 mm, Shutter : GI 1.20 mm, Shutter Width / Active Shutter Width : 808.00 mm, Frame Profile: 143.00 mm X 57.00 mm, Frame Profile type : Normal, Frame Rebate : Double, Door type : Single leaf door, Infill Material : Honey Comb, Vision Panel Active: 200 mmX300 mm. 8nos Ball bearing butt hinge, BB3090F, SS304, of size 100 x 75 x 3mm with screws in SSS , 1no Euro profile half cylinder 3005, 42mm Key x Blank, Silver satin finish , 2no Surface door closer TS73, size EN2/3/4, with standard arm, Silver finish, 1no Clear glass, 6mm of size 200 x 300mm, 2 nos concealed flush bolt, Mortise sash lock with lever handle on side and panic lever on other side. The door should have a minimum fire rating of 2hrs . Wall Opening Size 1000X2200 mm. 63 Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge ( Door handle, lock and stopper etc to be paid separately) 64 Providing and fixing SS H handle having min 45 cm length in toughed glass door including all necessary screws etc. complete. 65 Providing and fixing of glass door SS Patch Lock with out handle in toughened glass door including all necessary screws etc. complete 66 Fixing 12 mm thick frameless toughened glass partition of approved brand and manufacture, including top & bottom fixing arrangement and making necessary holes etc. for fixing required fittings, all complete as per direction of Engineer-in- charge. 67 Providing and fixing 3M Fasara frosted etching film of thickness 25 microns self- adhesive of approved colour, shade, and quality with cutting as per approved design and pattern, including cleaning of glass and making surface smooth for fixing of film to the surface, all completed as per the direction of the engineer in charge. 68 Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.80x1.25 mm M.S. laths with 1.25 mm thick top cover 69 Providing and fixing ball bearing for rolling shutters. 70 Sanitary and CP Fittings 71 Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm Sand Cast Iron P or S trap, 10 litter low level white P.V.C.flushing cistern, including flush pipe, manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever require:White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests 72 Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:W.C. pan with ISI marked white solid plastic seat and lid 73 Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm or 340x410x265 mm sizes respectively. 74 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Flat back wash basin size 450x300 mm with single 15 mm C.P. brass pillar tap 75 Providing and fixing ceramic urinal partitions of standard size as per direction of Engineer-in Charge and of approved shade 76 Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.15 mm nominal bore 77 Providing and fixing uplasticised PVC connectionpipe with brass unions: 30 cm length15 mm nominal bore 78 Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet:150 mm diameter 79 Providing and fixing C.P brass stop cock ( concealed) of standard design and of approved make conforming to IS: 893115 mm nominal bore 80 Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS: 893115 mm nominal bore 81 Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required:Kitchen sink without drain board610x510 mm bowl depth 200 mm 82 Providing and fixing white vitreous china laboratory sink with C.I brackets, C.P. brass chain with rubber plug 40 mm C.P brass waste and 40 mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required:Size 600x450x200 mm 83 Supplying and fixing CP Towel rod 45cm or nearest available length including cost of materials and labour charges etc complete as per the direction of site Engineer-in- charge. 84 Supplying and fixing CP Health faucet good quality including cost of materials and labour charges etc. complete as per the direction of site engineer-in-charge. 85 Flexible pipe32 mm dia 86 Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with C.P. brass screws and washers complete. 87 Supplying and fixing PVC Floor Trap 100mmx75mm size without Jali including cutting open, boring through RCC slabs and making good the damages. 88 Providing and fixing SS grating of approved quality and colour. Rectangular type with openable lid150 mm nominal size square 100 mm diameter of the inner hinged grating. 89 Providing and fixing disabled friendly bathroom kit with all accessories including wash closet with soft close seat cover and cistern with twin flush setting, wash basin of min dimensions 510mm x 400mm with all necessary fittings including Angle cock, Connection pipe, waste pipe, Spatula Lever basin mixer, Wall mounted 600mm long, Wall mounted grab bar 600 mm long and wall mounted hinged rail 750 x 750, Health Faucet with angle cock. Recommended Makes : CERA , Hindware, Jaguar or equivalent . 90 Plumbing 91 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge.Internal work - Exposed on wall32 mm nominal outer dia pipes 92 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge.Internal work - Exposed on wall40 mm nominal outer dia pipes 93 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge.Internal work - Exposed on wall50 mm nominal outer dia pipes 94 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes& fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge.Concealed work, including cutting chases and making good the wall etc.20 mm nominal outer dia pipes 95 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes& fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge.Concealed work, including cutting chases and making good the wall etc.25 mm nominal outer dia pipes 96 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :32 mm nominal bore 97 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :40 mm nominal bore 98 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :50 mm nominal bore 99 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :25 mm nominal bore 100 Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 32 mm dia 10Kgf/cm2- Internal work - Exposed on wall 101 Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 50 mm dia 10 Kfg/cm - Internal work- Exposed on wall 102 Providing and fixing PVC pipes including fixing the pipe with clamps/ clip at 1.00 m spacing . This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 63 mm dia 6 Kgf/cm2 - External work - Exposed on wall 103 Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 63 mm dia Elbow 104 Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes including jointing with PVC solvent cement - 63x63x63 mm dia Tee 105 Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 63x50 mm dia Reducer 106 Supplying and fixing PVC Floor Trap 100mmx75mm size without Jali including cutting open, boring through RCC slabs and making good the damages. 107 Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge.Concealed work, including cutting chases and making good the wall etc. 32 mm pipe 6Kgf/cm2 108 Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge.Concealed work, including cutting chases and making good the wall etc. 40 mm pipe 6Kgf/cm2 109 Providing and fixing PVC pipes including fixing the pipe with clamps/clips at 1.00 m spacing. This included jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 75 mm dia 6Kgf/cm2 - External work- Exposed on wall 110 Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 75 mm dia Bend 111 Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 75x75x75 mm dia Door Tee 112 Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 75 mm dia Vent cowl 113 Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement -75 mm dia End cap 114 Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement -75 mm dia 45 degree Elbow 115 Providing and fixing PVC pipes including fixing the pipe with clamps/ clips/ at 1.00 m spacing . This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 110 mm dia 6 Kgf/cm2 - External work- Exposed on wall 116 Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement- 110 mm dia Bend 117 Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110x110x110 mm dia Door tee 118 Providing and fixing PVC moulded fittings /accessories for Rigid PVC pipes, including jointing with PVC solvent cement -110 mm dia Vent cowl 119 Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement -110 mm dia End Cap 120 Providing and fixing PVC moulded fittings / accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110 mm dia 45 degree Elbow 121 Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110x75 mm dia Reducer 122 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :80 mm nominal bore 123 Providing and placing on terrace (at all floor levels) polyethylene water storage tank:ISI 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 124 Yard Plumbing 125 Providing and fixing PVC pipes includings jointing of pipes with one step pvc solvent cement, trenching , refilling & testing of joints complete as per direction of Engineer in Charge. 150 mm dia 6 Kgf/cm2 126 Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes,including jointing with PVC solvent cement - 110 mm dia Socket/ coupling 127 Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand) with R.C.C. top with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix ( 1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size,) inside plastering 12 mm thick with cement mortar 1:3 ( 1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) finished with a floating coat of neat cement complete as per standard design:Inside size 120x90 cm and 90 cm deep including C.I. cover with frame ( medium duty ) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg ( weight of cover 58 kg and weight of frame 58 kg):With common burnt clay F.P.S ( non modular) bricks of class designation 7.5 128 Providing and fixing on wall face unplasticised- PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion Single pushfit Coupler110 mm 129 Providing and fixing on wall face unplasticised- PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansionBend 87.50110 mm bend 130 Tile and Granite work 131 Providing and laying Matt Finished vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 1200 x 600 mm. 132 Providing and laying Matt finished Vitrified tiles indifferent sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, ofapproved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 1200x600 mm 133 Providing and laying Anti Skid matt vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600 x 600 mm. 134 Providing and laying premium vitrified bathroom wall tile in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete. 135 Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg). including filling /grouting and finishing complete as per direction of Engineer-in-charge.Size of Tile 600x600 mm 136 Marble work gang saw cut (polished and machine cut) of thickness 18 mm for wall lining ( veneer work), backing filled with a grout of 12 mm thick average in cement mortar 1:3 ( 1 cement : 3 coarse sand), including pointing with white cement mortar 1:2 ( 1 white cement : 2 marble dust) with an admixture of pigment to match the marble shade ( To be secured to the backing by means of cramps, which shall be paid for separately).Area of slab over 0.50 sqm 137 Providing and fixing 18 mm thick gang saw cut, mirror, polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 ( 1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Granite of any colour and shade. Area of slab over 0.50 sqm 138 Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent. 139 Providing edge moulding to 18 mm thick marble stone counters, vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer -in-Charge.Granite work 140 Extra for providing opening or required size & shape for wash basin/kitchen sink in kitchen platform, vanity counter and similar location in marble/granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. 141 Providing and laying tactile tile (for vision impaired persons as per standards) of size 300x300x9.8mm having with water absorption less than 0.5% and conforming to IS: 15622 of approved make in all colours and shades in for outdoor floors such as footpath, court yard, multi modals location etc., laid on 20mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as per direction of Engineer-in-Charge. 142 Providing and fixing 12 mm thick gang saw cut, mat /rough finished granite, machine cut for steps, ramps or inclined plate form with raking and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 ( 1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. 143 Structural steel 144 Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) 145 Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. 146 Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. 147 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes 148 Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05%), total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 149 False ceiling 150 Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/ sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37 mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50 mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25 mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5x25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound, jointing tapes, finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturers specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with:12.5 mm thick tapered edge gypsum moisture resistant board 151 Providing and fixing tiled false ceiling of approved materials of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections (galvanized @ 120 grams per sqm, both side inclusive) consisting of main T runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200mm center to center and cross T of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main T at 600 mm center to center to form a grid of 1200x600 mm and secondary cross T of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main T runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x 1.6 mm fixed to ceiling with 12.5mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85x 30x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T- sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer -in-charge.12.5 mm thick square edge PVC Laminated Gypsum Tile size 595x595 mm made of Gypsum plasterboard , manufactured from natural gypsum as per IS 2095 part I and laminated with white 0.16 mm thick fire retardant PVC film on the face side and 12 micron metalized polyster on the back side with all edges sealed with the face side PVC film which goes around and wraps the edges and is bonded to the edges and the back side metalized polyster film so as to make the tile a completely sealed unit. 152 Rainwater Harvesting ,Fire Tank,Septic Tank 153 Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.Ordinary rock 154 Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.Ordinary or hard rock 155 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. 156 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size) 157 Providing and laying in position machine batched and machine mixed design mix M- 25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to siteof laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work upto plinth level 158 Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more 159 Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels/ subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineerin-charge. The product performance shall carry guarantee for 10 years against any leakage.For vertical surface two coats @0.70 kg per sqm 160 Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels/ subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineerin-charge. The product performance shall carry guarantee for 10 years against any leakage.For horizontal surface one coat @1.10 kg per sqm. 161 Supplying and fixing C.I with frame for manholes: 600mm x 600mm ( heavy duty) the weight of the cover and frame shall not be less than 208 kg 162 Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of Joints complete as per direction of engineer in charge.110 mm dia 6Kgf/cm2 163 Providing and placing on terrace (at all floor levels) Stainless Steel 304as per IS 5522:1992 of capacity 5000 Litreswith suitable fixing arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 164 Providing and fixing of Fire Rated door 1200x2100mm- Hollow metal fire doors at all levels from ISO 9001-2015 certified Manufacturer. Fire door should be as per NFPA 80 and NFPA 252. All fire doors should be tested at UL for 120 minutes and should pass both UL10B and UL10C. Doors shall be made from pressed galvanized steel confirming to IS277 as per following specification.Frame:Door frame shall be single rebate grooved profile of size 125 x 55 mm made out of 1.6 mm (16 gauge) minimum thick galvanized steel sheet. Frames shall be mitered and field assembled with self-tabs. Frames to have in build grooved sealing system and shall be site fitted with fire rated EPDM gasket as standard. All provision should be mortised, drilled and tapped for receiving appropriate ANSI UL labeled hardware. Frames should be provided with back plate bracket and anchor fasteners for installation on a finished plastered masonry wall opening. Frames shall be filled with fire rated puff and the gaps shall be sealed with silicon sealant.Shutter: Door leaf shall be 46 mm thick fully flush double skin door without vision lite. Door leaf shall be manufactured from 1.2 mm (18 gauge) minimum thick galvanized steel sheet.The infill material shall be resin bonded honeycomb core. All doors should be factory prepped for receiving appropriate hardware and provided with necessary reinforcement for hinges, locks, and door closers as per ANSI standard. For pair of doors integrated astragals has to be provided on the meeting stile for both active and inactive leaf.Door and frames shall be finished Pure Polyester Powder coated and shall have passed minimum 500 hours of salt spray test.Vision glass: The glass shall be 5mm clear fire rated glass of equal rating and not exceeding size of 114 sq. inches.Door Hardware: Stainless steel Ball bearing Hinges 3 Nos, Minimum 90Kg hydraulic surface applied rack and pinion door closers, Mortice Sash Lock with cylinder. One Side Handle and Other Side with 2 point Panic Bar. 165 Road Work 166 Construction of granular sub- base by Providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, Carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in- Charge.With Material conforming to Grade - I ( size range 75 mm to 0.075 mm) having CBR Value- 30 167 Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge.80 mm thick C.C. paver block of M-30 grade with approved color design and pattern. 168 Water proofing 169 Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg /sqm mixed with water proofing cement compound @ 0.126 kg/ sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. 170 Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying : a) after surface preparation, first layer of slurry of cement @ 0.488 kg/ sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. laying second layer of fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm. c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/ sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around. d) fourth and final layer of brick tilling with cement mortar (which will be paid for separately. For the purpose of measurement the entire treated surface will be measured) 171 Landscaping 172 Supplying of Flowering Shrubs (Heliconiya st. Vincent red, Ixora bush, Cana durf etc..) 173 Plantation of Trees, Shrubs, and Hedge at site i/c watering and removalof unsaverieable material?s as per direction of officer in charge (including cast of plant & water )Cost of plantation per trees plants (for 100 nos.=427.45/100) 174 Providing and Laying Landscaping of outdoor area with buffalo grass and small plants with all necessary levelling and filling as required. 175 Signage 176 Providing and fixing in position the signage board made out of 3 mm opaque PVC foam board of computerised cut, PVC non reflective self adhesive vinyl painted foam board of required size and colour. 177 Providing and fixing non lit Signages made of CNC Cut Stainless Steel projected letters and fixing it at site with all necessary fitting arrangements and accessories as per the design and requirement on instructions of the engineer in charge. 178 Furniture 179 Two tiered reagent racks (MS with powder coating) with granite top of 150 mm depth for side workbenches. The two tier should be placed at a minimum spacing of 300 mm. The item should be in compliance with IS 4209 (2013), NABL etc. The Length should be customized as per lab workbench and vertical posts must be placed at appropriate spacing. 180 Supply and Installation of Sink Module with SinkEach sink module should have a minimum dimension of 900 mm (L) x 900 mm (W) x 900 mm (H) and made of MS as per IS 1730 shall be designed with a single cabinet (with 2 shutter, SS304 hinges for easy and noiseless opening and closing mechanism). This module should include a sink made of 5 mm thick polypropylene with black color body. Minimum Dimension of the sink: 450 mm (L) x 600 mm (W). Sink should include PVC tap connection-15mm diameter (Goose neck type), grating etc. The sink module shall be portable and provided with 18mm thick granite table top (with cut out for providing sink). Item to be inclusive of all necessary fitting arrangement.The item should be in compliance with IS 4209 (2013), NABL, WHO etc. 181 Supplying and Fixing of Lab work Table with Granite Top supported over 18mm thick marine plywood , frame work with with GI members with Heavy Duty Levelers, minimum dimension of 2000mm L x 750 mm D 182 Supplying and Fixing of Lab work Table with Granite Top supported over 18mm thick marine plywood , frame work with with GI members with Heavy Duty Levelers, minimum dimension of 2000mm L x 890mm D 183 Supply, Installation, Testing and Commissioning of Eye wash with Brass inject mould with epoxy powder coated body with auto released Valve and cup shaped water dispenser with min 1/2 HP power pressure booster pump 184 Counter Height Stools :Supply and erection of counter height stools ( bar stools ) of following specifications : Revolving adjustable Chrome plated steel body chairs with resistance to the corrosion. Cushion Seat with Lift mechanism for Adjustment of height. Minimum height 750mm before expansion. Medium Back rest and arm rest. Item shall be of reputed make. 185 Office Chair: Non-revolving executive chair with fixed armrest providing natural resting for arms. Seat with PU cutted foam backed fabric, back rest with mesh type fabric, Upholstery: Heavy duty rubber backed fabric in BLACK ( Size -55x60 cm) 186 Executive Chair: Medium back ergonomic chair with five nos. star shaped Nylon base. Castor: 50mm diameter nylon twin wheel, gas lift height adjustment, back angle adjustment , Fixed armrest providing natural resting for arms. Seat with PU coated foam backed fabric, back rest with mesh type fabric, upholstery: Heavy duty rubber backed fabric in BLACK 187 Revolving Chair: Medium back ergonomic chair with five nos. star shaped Nylon base. Castor: 50mm diameter nylon twin wheel, gas lift height adjustment, back angle adjustment , Fixed armrest providing natural resting for arms. Seat with PU coated foam backed fabric, back rest with mesh type fabric, upholstery: Heavy duty rubber backed fabric in BLACK 188 Cabinet/Wardrobe: Providing and fixing Cabinet/Wardrobe unit with 18 mm thick Multi wood board with one side decorative and other side balancing lamination. cupboard shutters edge to be sealed with PVC edge bending tape 2.00 mm thick of approved brand including ISI marked nickel plated bright finishing M.S. piano hinges conforming to IS:3818 marked with fixing chromium plated brass 50 mm cupboard or wardrobe knobs, special quality chromium plated brass cupboard locks with six levers of approved quality including necessary screws etc. complete. Depth of shelves to be 300-600mm and shelves to be fix with proper support and bracket holders. as per layout drawing approved by Engineer in charge. Make laminate: Greenlam/ Merino / Century. Only front elevation will be measured. 189 Supply and erection of Airport type 3 seater waiting chair with powder coated chromium finish having minimum dimensions 1675mm length X 710mm width X 775mm total height and 400mm seat height . Seat: High quality cold rolled 1.2mm thick steel perforated sheet pressed and welded to form the shape. Arm & Leg: High quality 1.2mm thick MS Tube / Sheet . Cross bar: High quality cold rolled 2mm thick steel sheet pressed and welded to form the shape. 190 Table of size Min 2300x600mm Made of minimum 18mm BWR ISI (303 Grade) plywood (Century, Greenply, Fineply or equivalent). On top and all sides with 1mm thick hot press (3M or Henkel) laminates (Brand MERINO, Associates or equivalent) of approved colour and pattern as per the design. The table is provided with 1 drawer, 1 Storage, 1 key board locks, handles, mini fix, dowels and screws. Exposed edges to be finished with 0.8 mm edge band as per specified colour. 191 Supply of wooden table with one drawer and Cupboard unit made of hard wood varnishing/painting all complete. Size: 1200x600x750mm 192 Providing & supply of Conference Table with executive chair of 13 Pax with the following specifications.Table top size :3600 x 1200mm. Table Tops –made of 25mm thick MDF with waterfall top edges finished in PVC Membrane using unique wrap around technology for better aesthetics & long lasting use. Under structure – Legs made of 25 mm thick standard Black matt colour post formed panels interconnected with 18mm thick standard Black matt colour pre-laminated modesty panels, with height adjustable levelers to take care of uneven floors. Wire Management & Concealed wire management to take care of basic wiring requirements both horizontally & vertically. For closed configurations, liftable top cover, made of 12mm MDF finished in PVC Membrane, is provided to access the horizontal wire carrier. Vertical wire management is through flexible vertical wire manager, popup grommet with power & RJ45 Socket. Designed for Flexibility through modular Construction, PVC Membrane Finish Tops for seamless surface, Post formed Legs for safe use, Provision for easy wire management, Upgradeable / reconfigurable for future needs. 13 Nos Revolving adjustable type Medium height Back Office Chair with arm rest with back tilt and swivel mechanism constructed out of mild steel and high quality plastic. 193 Supply of wooded Chairs with armrest of Hard Wood Plank Seat and Reaper Back. 194 Supply of Wooden Bench and Desk made up of Mahagani of minimum size - Bench Size :1 83x30X46cm Desk Size :183x41x75 cm 195 Supply and installation of steel podium made of SS304 with min dimensions 500mm X 450 mm X 1200mm and having a sloped top surface, and having a decorative/ plain front face all made of SS 304 as per the design and approvals of the architect/ Engineer - In - Charge 196 Wiring-General Electrical work 197 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C 198 Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. 199 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 2x1.5 sq.mm + 1x1.5 sq.mm earth wire 200 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire 201 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 2 X 4 sq. mm + 1 X 4 sq. mm earth wire 202 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 2 X 6 Sq.mm + 1 x 6 sq.mm earth wire 203 Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C 204 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 2 X 10 sq. mm + 1 X 6 sq. mm earth wire 205 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 2 X 16 sq. mm + 1 X 6 sq. mm earth wire 206 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 4 X 4 sq. mm + 2 X 4 sq. mm earth wire 207 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 4 X 10 sq. mm + 2 X 6 sq. mm earth wire 208 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 4 X 16 sq. mm + 2 X 6 sq. mm earth wire 209 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required. 20 mm 210 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm 211 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required. 32 mm 212 Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor,unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. 2 Pair 213 Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required. 214 Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. 215 Fixtures 216 Supply and Fixing suitable size modular GI box with cover in front on and providing and fixing 1 no RJ 45 including connections as required. 217 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings). 218 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. 219 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.Telephone socket outlet 220 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm) 221 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.TV antenna socket outlet 222 Supply and Installation of surface/recess mounted LED 2x2 luminaire with CRCA housing suitable with fully diffused diffuser for general lighting. The luminaire should have CRI > 80 and CCT of both 6500K/5700K, Cool White Light. The luminaire shall be compliant with IP20 and IK02 classification. Luminaire shall be designed to emit at least 3700 nominal lumens and efficacy of atleast 105 lumen/watt and Minimum system wattage of 36 Watts. The luminaire shall be designed so as to ensure lumen depreciation of up to 30% over 50k burning hours. The electronic driver used shall have a power factor >0.95 and THD. Make-Philips, Crompton, Wipro or equivalent 223 Supply, conveyance and Installation of compact, 2 feet,10-15W,LED tube light with high lumen giving soft glare free light including all required mounting accessories, frames complete. (Philips/WIPRO/Havells or equivalent) 224 Supply, Installation of surface mounted LED Tubelight. The luminaire should have CRI > 80 and CCT of both 6500K/5700K. The luminaire shall be compliant with IP20 and IK02 classification. Luminaire shall be designed to emit at least 3600 nominal lumens and efficacy of atleast 105 lumen/watt and Minimum system wattage of 30 Watts. The luminaire shall be designed so as to ensure lumen depreciation of up to 30% over 25k burning hours. The electronic driver used shall have a power factor >0.95 and THD. Make - Philips, Crompton, Wipro, Havells 225 Supply, Installation of surface/recess mounted LED Round/Square luminaire with CRCA housing suitable with fully diffused diffuser for general lighting in office areas. The luminaire should have CRI > 80 and CCT of both 6500K/5700K. The luminaire shall be compliant with IP20 and IK02 classification. Luminaire shall be designed to emit at least 3600 nominal lumens and efficacy of atleast 110 lumen/watt and Minimum system wattage of 10 -15 Watts. The luminaire shall be designed so as to ensure lumen depreciation of up to 30% over 50k burning hours. The electronic driver used shall have a power factor >0.95 and THD. Make-Philips, Crompton, Wipro 226 Supply, conveyance and Installation of compact 10-15W LED Bulkhead Light giving soft glare free, Cool White light & complete with electronic driver including all required mounting accessories, frames, complete ( Make: Philips/WIPRO/Havells or equivalent) 227 Supply, Installation, Testing and Commissioning of 1400 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, ashers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. Make: Atomberg/Havells/ Orient Electric/ Crompton or equivalent 228 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, ashers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. Make: Atomberg/Havells/ Orient Electric/ Crompton or equivalent 229 Supplying, conveyance and Installation of 150-250 mm sweep,1350 rpm, 3 - 5 blade BLDC Exhaust Fan including frames and all mounting accessories complete.Recommended Make: Atomberg Efficio/Crompton Brisk Air 230 Supplying, conveyance and Installation of BLDC Type Wall Fan having 3 blade, 400 mm sweep, Speed 1350 rpm, Air Delivery 70 CMM minimum, Wall Mount Fan including frames and all mounting accessories complete. Recommended Make: Atomberg Renesa/V-Guard ENVIRO WF BLDC/Havells Platina 231 Supply, Installation, Testing and Commissioning of 450 mm sweep, 900 rpm heavy duty exhaust fan with louver in existing opening including making good the hole to suite the size of above fan complete with connections using 3 core 1.5sqmm multi core pvc sheathed copper conductor cable etc as required. 232 SITC of skirting light fitting with white LED 3 module along with suitable size modular metal box with inner and outer plates with all accessories. 233 Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providng and fixing 2 Nos. 3 pin 5/6 A modular socket outlets and 2 Nos. 5/6 A modular switches, connection etc. as required. (For light plugs to be used in non residential buildings). 234 Supplying & fixing suitable size Gl box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, C curve including connections, painting etc. as required. lCD 235 Supply and installation of 2 Nos. 4 ft MS powder-coated hanging rods for tube lights, including supply and laying of 1.5 sqmm copper PVC insulated FRLS wire (3 runs: Phase, Neutral, Earth), necessary hardware (ceiling clamps, saddles, junction box, connectors), complete mounting, terminations, testing, and labour charges — complete in all respects. 236 Network and CCTV System 237 Supply of 16 ports Network Switch, Rack-mountable 10/100/1000 Mbps, Switching capacity 35.7 Mbps Features: Flow control, Layer 2 switching, auto-negotiation, auto- uplink (auto MDI/MDI-X), Weighted Round Robin (WRR) queuing, Quality of Service (QoS) Power: AC 120/230 V (50/60 Hz) complete. Make D-Link/TP Link/Cisco or equivalent 238 Supply Installation Testing and Commissioning of 32 channel embedded Linux NVR (Network Video Recorder), must connect 32 channel IP cameras, Should support min 2 SATA HDD and each should support Min 2TB and must record video simultaneously, (Recording Type: Continuous, Motion Detection, Alarm, Smart Event, Event Motion Detection, Alarm, Smart Event), Video Compression H.265(HEVC)/H.264+/H.264, 2 Year Warranty, Image quality should be maintained throughout the warranty period. Make: CP Plus/Hikivision/Dahua or equivalent 239 Network Switch for CCTV. 16 Port PoE Switch 1000BASE-T Copper Ethernet PoE+ connections, 10M/100M/1G RJ-45 copper ports, 1000BASE-X Fiber SFP ports, 16 port Auto sensing 10/100/1000 Mbps PoE, minimum CPU memory 512 MB with 2 SFP/combo ports, Energy Efficient Ethernet (IEEE 802.3az) Make: CP Plus/Netgear or equivalent 240 Supply, Conveyance and Installing of 2MP IP Dome/Bullet Camera having Progressive Scan True Day and Night Colour IR Camera having effective pixel of 2 MP, Video frame rate of 2MP @30FPS, Minimum illumination of 0.01 [email protected], 0 lux@IR On, 20 M IR Range, 24 IR LED, AWB, AGC, BLC, 2D Noise reduction, with 3.6mm board lense, 12 VDC, PoE IP67 rated weatherproof performance. 1 year warranty. Make: Bosch/CP Plus/Honeywell or equivalent 241 Supply and fixing of 6U wall mounting rack with supply and fixing of mounting brackets for support Lockable Front Door and Detachable Side Doors, Cable Manager and PDU of 4 or 6 sockets including cooling fan with accessories complete 242 Supply Installation Testing & Commissioning of 16 Port Loaded Cat 6 - U/UTP Modular Toolless Patch Panel having a metal structure enabling them to be durably fixed to the uprights of the 19 chassis. Include rear cable manager to hold cables without need for cable ties. The termination of I/0s shall be without any manual crimping tools. 243 Supply and fixing of 4U wall mounting rack with supply and fixing of mounting brackets for support Lockable Front Door and Detachable Side Doors, Cable Manager and PDU of 4 or 6 sockets including cooling fan with accessories complete. 244 Supply and connecting 2 meter long CAT6 cable Patch cord having RJ45 connectors crimped at both ends, to the existing outlets as required. Make: D-Link/TP-Link or equivalent 245 Supply and Installation of LED Color display of minimum 32 inch screen, complete, UHD display Make: LG/Samsung/Panasonic or equivalent. 246 Supplying and drawn of UTP 4 pair CAT 6 LAN cable in the existing surface/recessed steel/PVC conduit as required1 run of Cable 247 Supply, Installation and Integration of Dual Band WiFi Access Point on false ceiling along with accessories, having Fast Wireless Speed, simultaneous 2.4GHz 300Mbps and 5GHz, 867Mbps Dual Band connections for 1.2Gbps of total available bandwidth, Superior Coverage of Four Fixed External antennas provide stable wireless connections and optimal coverage, App Control, Interface of 1× 10/100 Mbps WAN Port and 4× 10/100 Mbps LAN Ports having Working Modes (Router Mode / Access Point Mode). Make: TP-Link/Netgear/DLink or equivalent 248 UPS 249 Supply, Installation, Testing and Commissioning of True on-line Double Conversion 10 KVA UPS system with 3:3 Crest Factor Three Phase Input Three Phase Output. Inversion shall be Microprocessor controlled with instantaneous sine wave Control using IGBT. UPS shall have standard display features, alarms, safeties, etc Input Voltage range : a) Phase – Three Phase with ground b)Voltage range 190 VAC – 470 VAC c)Input Frequency :50/60 Hz d)Power Factor : 0.95 or above e)THD : less than 5% with full load Bypass f) Voltage Range – 200VAC – 240 VAC ) Frequency range – 45-55 Hz/55-65 Hz Output Voltage Range h)Voltage Range – 200VAC – 240 VAC i)Frequency range – 50/60 Hz j)Voltage distortion – linear load <= 2% k)Voltage distortion – nonlinear load <= 5% l)Output waveform – pure sinewave m) Crest Factor – 3:1 Minimum Back up time : Continuous 30 Minutes at full load Rectifier shall be Full wave Type (Shall fully meet the specified input power requirements) Battery Type: Sealed Lead Acid Maintenance Free DC Voltage : 96V DC System, Battery Nos and capacity shall be designed for optimum storage space. Installation &Commissioning Required Breakers also needs to be provided in input and output side for the UPS. Make: Liebert Vertiv/APC by Schneider/Numeric by Legrand 250 Cable Trays 251 Supplying and installing following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.375 mm width X 50 mm depth X 2.0 mm thickness 252 Supplying and installing following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.150 mm width X 50 mm depth X 1.6 mm thickness 253 Fan Clamp 254 Providing and fixing 16 mm S.S. Fan clamps of standard shape and size in existing R.C.C. slab, including cutting chase, anchoring clamp to reinforcement bar, including cleaning, refilling, making good the chase with matching concrete, plastering and painting the exposed portion of the clamps complete. 255 DB and Switchgear 256 Supply and installation ofsheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - three phase double cover (IP 42/43) 257 Supply and installation ofsheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - double cover TPN vertical DB with provision for fixing MCCB as incomer and SP/ TP MCB as outgoing (IP 42/43) 258 Supply and installation ofsheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required6 way (8+12) - double cover TPN vertical DB with provision for fixing MCCB as incomer and SP/ TP MCB as outgoing (IP 42/43) 259 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator6 way, Double door 260 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole 261 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole and netural 262 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Double pole 263 Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps 264 Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps 265 Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps 266 Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps 267 Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps 268 Supplying and fixing TP sheet steel enclosure on surface/ recess along with 16/25/32amps 415 volts C curve TP MCB complete with connections, testing and commissioning etc. as required. 269 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole 270 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole and neutral 271 Earthing and Lightning Arrestor 272 Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re- filling etc. as required. 273 Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required. 274 Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required. 275 Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. 276 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. 277 Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm) 278 Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 nos. of G.I. bolts, nuts, chuck nuts and spring washers etc. complete as required. 279 Laying copper/ G.I. tape 32 mm X 6 mm from earth electrode directly in ground as required. 280 Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube,having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required. 281 Jointing copper / G.I. tape (with another copper/ G I tape, base of the finial or any other metallic object) by riveting / nut bolting/ sweating and soldering etc as required. 282 Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For horizontal run) 283 Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For vertical run) 284 Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required4.75 mm copper conductor (6 SWG) 285 Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.4.00 mm (8 SWG) 286 Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.4.75 mm (6 SWG) 287 Street Lights 288 Supply Conveyance, installation, testing and commissioning of 36/40W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer) 289 Supply, fabrication, conveyance and fixing the following sizes of B class GI pipe bent to shape / cut and welded to shape and fixing the same to wall / parapet using clamps as noted along with each size, painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer, making good the damages, colour washing etc as required.32 mm dia with HG company fabricated clamps 290 Water Purifier 291 Supply and Installation of Water Purifier having Multi-Stage Filtration: RO (Reverse Osmosis), UV (Ultraviolet), UF (Ultrafiltration), Storage Capacity: 7-9 Liters, Purification Features: RO: Removes dissolved impurities, heavy metals, and salts.UV: Kills bacteria, viruses, and other microorganisms. UF: Filters out fine particles and microorganisms. Mineral Booster: Adds essential minerals to enhance water taste.TDS Controller: Adjusts Total Dissolved Solids for taste preference. ActiveCopper: Infuses copper ions into the water for added health benefits.Aqua Taste Booster: Enhances the taste and maintains optimum pH level. In-Tank UV Disinfection: Keeps stored water pure.Smart Display/Indicators: Alerts for filter change, UV fail, water level, and service needs. Super Fine Sediment Filter: Removes fine and coarse particulate impurities. Water Level Indicator: Monitors the purified water level in the storage tank. Make: Aquaguard Aura 7L/ Bluestar Aristo 7L/Kent Grand Plus ZWW 9-Litre/ LG 8L 292 LT Cabling and Termination 293 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.2 core 6 sq mm with factory made clamp 294 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 35 sq mm with factory made clamp 295 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 10 sq mm with factory made clamp 296 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 16 sq mm with factory made clamp 297 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 25 sq mm with factory made clamp 298 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 240 sq mm 299 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 240 sq. mm (62mm) 300 Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.3.5 core 400 sq mm 301 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 400 sq. mm (82mm) 302 LT Panels 303 Fabrication, Supply, Installation, Testing & Commissioning of floor mounted, cubical type, dust & vermin proof, powder coated of approved shade Electrical panel fabricated out of sheet steel not less than 2.0 mm thick. Wherever necessary, such sheet steel members shall be stiffened by angle iron frame work. General construction shall employ the principle of compartmentalization and segregation for each circuit. Unless otherwise approved, incomer and bus section panels or sections shall be separate and independent and shall not be mixed with sections required for feeders. Each section of the rear accessible type panel shall have hinged access doors at the rear. Overall height of the panel shall not exceed 2.4 meters. Operating levers, handle etc. of highest unit shall not be higher than 1.7 meters. Multi-tier mounting of feeder is permissible. The general arrangement for multi-tier construction shall be such that the horizontal tiers formed present a pleasing and aesthetic look. Cable entries for various feeders shall be either from top or bottom. Through cable alleys located in between two circuit sections, either in the rear or in the front of the panel. All cable terminations shall be through gland plates. There shall be separate gland plate for each cable entry so that there will not be dislocation of already wired circuits when new feeders are added. Cable entry plates shall therefore be sectionalized. The construction shall include necessary cable supports for clamping the cable in the cable alley or rear cable chamber. The bus bars shall be of aluminium of high conductivity electrolytic quality and of adequate section. All bus bars and connections shall be suitably sleeved / insulated in approved manner. All voltmeters and ammeters shall befl ush mounted of size minimum 96 mm conforming to class 1.5 of IS 1248 for accuracy. All voltmeters shall be protected with MCB. On all the incomers of M.V panels, ON/OFF indicating LED lamps shall be provided and shall be suitable for operation on AC supply. Phase indicating LED lamps shall be associated with necessary ON/OFF toggle switch. All small wiring for Controls, Indication etc. shall be with suitable FRLS/ HFFR (halogen free fire retardant) copper conductor cables. Identification ferrules shall be used at both ends of the wires. The panel shall comprise of incomers, outgoing feeders and bus coupler as specified. The entire switch panel shall be cubical type generally conforming to IS 8623:1993 for factory assembled switch board. All incoming AIR CIRCUIT BREAKER/ MCCB shall have suitable adjustable tripping current and the time delay settings. The entire panel shall have a common earth bar of size as specified with two terminals for earth connections. The panel shall be suitable for operation on 415V, 3 phase, 50 Hz AC supply with enclosure protection class IP-42 as required.Incomer : 400A 3kA 4 Pole MCCB - 1no Ics = 100% Icu rating Digital Voltmeter 0- 500V with selector switch & Digital ammeter (0-400A) with selector switch and CTs etc. LED type RYB phase indication lamps, ON, OFF, Trip indication lamps, set of aluminium bus bar 400A. Out going : 250A ,50kA 4 Pole MCCB - 2no Ics = 100% Icu, (with Hylam sheet & warning signages as required) Switch gear make should as per approved make list. Panel shall meet all necessary specifications as per local electrical body/Inspectorate norms. 304 Lift panel- Fabrication, Supply, Installation, Testing & Commissioning of floor mounted, cubical type, dust & vermin proof, powder coated of approved shade Electrical panel fabricated out of sheet steel not less than 2.0 mm thick. Wherever necessary, such sheet steel members shall be stiffened by angle iron frame work.General construction shall employ the principle of compartmentalization and segregation for each circuit. Unless otherwise approved, incomer and bus section panels or sections shall be separate and independent and shall not be mixed with sections required for feeders. Each section of the rear accessible type panel shall have hinged access doors at the rear. Overall height of the panel shall not exceed 2.4 meters. Operating levers, handle etc. of highest unit shall not be higher than 1.7 meters. Multi-tier mounting of feeder is permissible. The general arrangement for multi-tier construction shall be such that the horizontal tiers formed present a pleasing and aesthetic look. Cable entries for various feeders shall be either from top or bottom. Through cable alleys located in between two circuit sections, either in the rear or in the front of the panel. All cable terminations shall be through gland plates. There shall be separate gland plate for each cable entry so that there will not be dislocation of already wired circuits when new feeders are added. Cable entry plates shall therefore be sectionalized. The construction shall include necessary cable supports for clamping the cable in the cable alley or rear cable chamber. The bus bars shall be of aluminium of high conductivity electrolytic quality and of adequate section. All bus bars and connections shall be suitably sleeved / insulated in approved manner. All voltmeters and ammeters shall be fl ush mounted of size minimum 96 mm conforming to class 1.5 of IS 1248 for accuracy. All voltmeters shall be protected with MCB. On all the incomers of M.V panels, ON/OFF indicating LED lamps shall be provided and shall be suitable for operation on AC supply. Phase indicating LED lamps shall be associated with necessary ON/OFF toggle switch. All small wiring for Controls, Indication etc. shall be with suitable FRLS/ HFFR (halogen free fire retardant) copper conductor cables. Identification ferrules shall be used at both ends of the wires. The panel shall comprise of incomers, outgoing feeders and bus coupler as specified. The entire switch panel shall be cubical type generally conforming to IS 8623:1993 for factory assembled switch board. All incoming AIR CIRCUIT BREAKER/ MCCB shall have suitable adjustable tripping current and the time delay settings. The entire panel shall have a common earth bar of size as specified with two terminals for earth connections. The panel shall be suitable for operation on 415V, 3 phase, 50 Hz AC supply with enclosure protection class IP-42 as required.Incomer : 1) 63A 36kA 4 Pole MCCB - 1no Ics = 100% Icu rating, THERMAL MANGNETIC RELEASEDigital Voltmeter 0-500V with selector switch & Digital ammeter (0-63A) with selector switch and CTs etc. LED type RYB phase indication lamps, ON, OFF, Trip indication lamps, set of aluminium bus bar 63A. Out going : 1) 40A ,16-25kA TP MCB - 6 no Ics = 100% Icu, (with Hylam sheet & warning signages as required) Switch gear make should as per approved make list.Panel shall meet all necessary specifications as per local electrical body/Inspectorate norms. 305 Sub Panel- Fabrication, Supply, Installation, Testing & Commissioning of floor mounted, cubical type, dust & vermin proof, powder coated of approved shade Electrical panel fabricated out of sheet steel not less than 2.0 mm thick. Wherever necessary, such sheet steel members shall be stiffened by angle iron frame work.General construction shall employ the principle of compartmentalization and segregation for each circuit. Unless otherwise approved, incomer and bus section panels or sections shall be separate and independent and shall not be mixed with sections required for feeders. Each section of the rear accessible type panel shall have hinged access doors at the rear. Overall height of the panel shall not exceed 2.4 meters. Operating levers, handle etc. of highest unit shall not be higher than 1.7 meters. Multi-tier mounting of feeder is permissible. The general arrangement for multi-tier construction shall be such that the horizontal tiers formed present a pleasing and aesthetic look. Cable entries for various feeders shall be either from top or bottom. Through cable alleys located in between two circuit sections, either in the rear or in the front of the panel. All cable terminations shall be through gland plates. There shall be separate gland plate for each cable entry so that there will not be dislocation of already wired circuits when new feeders are added. Cable entry plates shall therefore be sectionalized. The construction shall include necessary cable supports for clamping the cable in the cable alley or rear cable chamber. The bus bars shall be of aluminium of high conductivity electrolytic quality and of adequate section. All bus bars and connections shall be suitably sleeved / insulated in approved manner. All voltmeters and ammeters shall be fl ush mounted of size minimum 96 mm conforming to class 1.5 of IS 1248 for accuracy. All voltmeters shall be protected with MCB. On all the incomers of M.V panels, ON/OFF indicating LED lamps shall be provided and shall be suitable for operation on AC supply. Phase indicating LED lamps shall be associated with necessary ON/OFF toggle switch. All small wiring for Controls, Indication etc. shall be with suitable FRLS/ HFFR (halogen free fire retardant) copper conductor cables. Identification ferrules shall be used at both ends of the wires. The panel shall comprise of incomers, outgoing feeders and bus coupler as specified. The entire switch panel shall be cubical type generally conforming to IS 8623:1993 for factory assembled switch board. All incoming AIR CIRCUIT BREAKER/ MCCB shall have suitable adjustable tripping current and the time delay settings. The entire panel shall have a common earth bar of size as specified with two terminals for earth connections. The panel shall be suitable for operation on 415V, 3 phase, 50 Hz AC supply with enclosure protection class IP-42 as required. Incomer : 1) 63A 36kA 4 Pole MCCB - 1no Ics = 100% Icu rating, THERMAL MANGNETIC RELEASEDigital Voltmeter 0-500V with selector switch &Digital ammeter (0-63A) with selector switch and CTs etc. LED type RYB phase indication lamps, ON, OFF, Trip indication lamps, set of aluminium bus bar 63A. Out going : 1) 32A ,16-25kA 4 Pole MCCB - 4 no Ics = 100% Icu, (with Hylam sheet & warning signages as required) Switch gear make should as per approved make list. Panel shall meet all necessary specifications as per local electrical body/Inspectorate norms. 306 SSB2- Fabrication, Supply, Installation, Testing & Commissioning of floor mounted, cubical type, dust & vermin proof, powder coated of approved shade Electrical panel fabricated out of sheet steel not less than 2.0 mm thick. Wherever necessary, such sheet steel members shall be stiffened by angle iron frame work.General construction shall employ the principle of compartmentalization and segregation for each circuit. Unless otherwise approved, incomer and bus section panels or sections shall be separate and independent and shall not be mixed with sections required for feeders. Each section of the rear accessible type panel shall have hinged access doors at the rear. Overall height of the panel shall not exceed 2.4 meters. Operating levers, handle etc. of highest unit shall not be higher than 1.7 meters. Multi-tier mounting of feeder is permissible. The general arrangement for multi-tier construction shall be such that the horizontal tiers formed present a pleasing and aesthetic look. Cable entries for various feeders shall be either from top or bottom. Through cable alleys located in between two circuit sections, either in the rear or in the front of the panel. All cable terminations shall be through gland plates. There shall be separate gland plate for each cable entry so that there will not be dislocation of already wired circuits when new feeders are added. Cable entry plates shall therefore be sectionalized. The construction shall include necessary cable supports for clamping the cable in the cable alley or rear cable chamber. The bus bars shall be of aluminium of high conductivity electrolytic quality and of adequate section. All bus bars and connections shall be suitably sleeved / insulated in approved manner. All voltmeters and ammeters shall be fl ush mounted of size minimum 96 mm conforming to class 1.5 of IS 1248 for accuracy. All voltmeters shall be protected with MCB. On all the incomers of M.V panels, ON/OFF indicating LED lamps shall be provided and shall be suitable for operation on AC supply. Phase indicating LED lamps shall be associated with necessary ON/OFF toggle switch. All small wiring for Controls, Indication etc. shall be with suitable FRLS/ HFFR (halogen free fire retardant) copper conductor cables. Identification ferrules shall be used at both ends of the wires. The panel shall comprise of incomers, outgoing feeders and bus coupler as specified. The entire switch panel shall be cubical type generally conforming to IS 8623:1993 for factory assembled switch board. All incoming AIR CIRCUIT BREAKER/ MCCB shall have suitable adjustable tripping current and the time delay settings. The entire panel shall have a common earth bar of size as specified with two terminals for earth connections. The panel shall be suitable for operation on 415V, 3 phase, 50 Hz AC supply with enclosure protection class IP-42 as required.Incomer : 1) 250A 36kA 4 Pole MCCB - 1no Ics = 100% Icu rating, THERMAL MANGNETIC RELEASEDigital Voltmeter 0-500V with selector switch & Digital ammeter (0-250A) with selector switch and CTs etc. LED type RYB phase indication lamps, ON, OFF, Trip indication lamps, set of aluminium bus bar 250A. Out going : 1) 63A ,16-25kA 4 Pole MCCB - 8 no Ics = 100% Icu, (with Hylam sheet & warning signages as required) Switch gear make should as per approved make list. Panel shall meet all necessary specifications as per local electrical body/Inspectorate norms. 307 Transformer 308 Supply , Installation, Testing and commissioning of 500 kVA outdoor unitized substation with an 11kV/433V dry-type cast resin transformer and a 630A VCB typically includes a compact prefabricated design conforming to IEC62271-202 standards, offering IP53/IP23 protection, and featuring compartmentalized construction to prevent accidental entry into energized areas. The substation is designed to withstand electrical impulses, thermal, and dynamic stresses, ensuring reliable and robust performance with low power loss and noise levels. The installation involves placing the substation on a prepared concrete plinth, connecting high-tension (HT) and low-tension (LT) cables, and ensuring proper earthing and safety measures. The commissioning process includes testing the transformer, switchgear, and protection systems to verify operational integrity. Make: Unipower/Intrans/Voltamp 309 MSB and APFC Panel 310 Supplying, installation, testing & commissioning of cubical type MAIN SWITCH BOARD suitable for 415 V, 3 Phase, 4 Wire 50 Hz AC supply system having front surface area 6 sq.mtr (Approx.) fabricated in compartmentalized design from CRCA sheet steel of 2 mm thick for frame work and covers, 3 mm thick for gland, plates i/c cleaning & finishing complete with 7 tank process for powder coating in approved shade, having 630 Amp capacity extensible type TPN aluminium alloy bus bars of height conductivity, DMC / SMC bus bars of high conductivity, DMC/ SMC bus bar supports, with short circuit withstand capacity of 31 MVA for 1 Sec., bottom base channel of MS section not less than 100 mm x 50 mm x 5 mm thick, fabrication shall be done in transportable sections, entire panel shall have a common copper earth bar of size 25 mm x 5 mm at the rear with 2 Nos. earth stud, solid connections from main bus bar to switch gears with required size of Al. bus bars and control wiring with sq. mm. PVC insulated copper conductor S/C cable, cable alleys, cable gland plates in two half, i/c providing following switch gears :- Interlocking:Electrical through advance contacts in MCCB/ ACB’s (incomers & bus couplers) and mechanical (castel key) interlocking should be provided to ensure that only one supply is available at a time on each section of bus and to eliminate any possibility of accidentally approaching two supplies at one bus section.Interlocking b(I) Incoming : 2 Nos 800 Amps (DG and MAINS) each four pole ACB of fault breaking capacity 50 KA (Ics=Icu upto 433 V manually operated, fitted with interlocked door, automatic safety shutters, mechanical ON/OFF and service/test/isolated position indicators and frame earthing contact, conforming to IS 1397- 2 : 1993 as amended up-to-date complete with following accessories for each MCCB(a) Independent manual spring closing mechanism- 1 No.(b) Microprocessor release (EMI & EMC certified) for over current, earth fault & short circuit protection- 1 set.(c) Digital* type Voltmeter (0-500 V), with selector switch & back up HRC fuses/MCBs-1 set. (d) Digital* type Ammeter (0-.600 Amp), with selector switch and one set of 3 nos. CT’s of ratio. 800/5A Class I accuracy and 15 VA burden- 1set. (Ratio to be fi lled up).(e) 3 Nos. Phase indication LED lamps with 2 Amp back up HRC fuse, breaker ‘ON’ indicating light with 2 A HRC fuse, test terminal block set, fuses, circuits as per standard practice, auxiliary contacts for positive interlocking of the breakers as required.(f) Shunt trip coil 220 V A.C. (II) Bus Bars :TPN aluminium bus bars of minimum of 800 Amps capacity with heat shrinkable coloured sleeves and i/c DMC/SMC bus bar cross section, size supports & their spacing etc. for withstanding fault level of 31 MVA for 1 Sec (II) Outgoing :(1) (a) 4 Nos. 250 Amp 4 Pole MCCB (Ics = 35 kA upto 433 V) (b) CT’s of ratio 250/5 Amps Nos. (c) Digital* type ammeter (0- 400 Ap) with selector switch set. (2) (a) 1 Nos. 200 Amp4 Pole MCCB for (Ics = 35 kA upto 433 V) (b) CT’s of ratio 200/5 Amps set (c) Digital* type ammeter (0- 250 Amp) with selector switch set. (3) 3 Nos 160 Amp 4 Pole MCCB (Ics = 35 kA upto 433 V) (b) CT’s of ratio 160/5 Amps set (c) Digital* type ammeter (0- 200 Amp) with selector switch set. The switchgears/measuring instruments shall be as per the Choice of the Engineer in charge. The panel shall be mounted on required structural steel supports and frames for mounting, the price quoted shall be inclusive of the same. The panel shall have suitable provision for connecting to the incoming cables of 3R x 400 sqmm XLPE Aluminium cables and shall be provided with necessary earth leakage relays as per the Inspectorate Norms. The panel shall be as per the IS standards and shall conform to all norms of EB/Inspectorate/CEA. Make of Switchgear : ABB/L & T/Schneider Electric/Siemens/Legrand 311 Design, Manufacture, Supply, Installation, Testing and Commissioning of Automatic Power correction Panel having Incomer: 250A, TPN MCCB, Digital Multifunction meter for V,A,F,PF With CTs CL:1 with RYB Indication lamps-1 Set 250A Aluminium bus bar with heat shrinkable insulation sleeves-1 set, Intelligent power factor controller with control MCBs etc. complete The panel shall comprise of suitable combination of capacitor banks upto a total of 100 kVAR and shall be designed as per the standards of Electrical Inspectorate/CEA. 312 DG and AMF Panel 313 Supply, Installing, Testing and Commissioning of & Silent Type& Diesel Generating set having CPCB IV+ acoustic enclosure having Prime Power Rating of 500 KVA, 415 volts at 1500 RPM, 0.8 lagging power factor at 415 V suitable for 50 Hz, 3 phase system & for 0.85 Load Factor and consisting of the followings: Diesel engine radiator cooled, electric start, of suitable BHP at 1500 RPM suitable for above output of alternator capable of taking 10% over loading for one hour after 12 hours of continuous operation. The engine will be fitted complete with all the required accessories. Engine mounted Instrument Panel fitted with and having digital display and necessary indication coupled to Synchronous alternator rated at 500 KVA, 415 volts at 1500 RPM, 3 phase 50 Hz, AC supply with 0.8 lagging power factor. Both the engine and alternator shall be mounted on suitable base frame made of MS channel with necessary reinforcement which shall be installed on suitable cement concrete foundation and vibration isolation arrangement as per recommendations of manufacturer. Daily service fuel tank of 440-460 litres capacity fabricated out of 3 mm thick M.S. sheet complete with all standard accessories and fuel piping between fuel tank and diesel engine with MS class ‘C’ pipes of suitable dia. Complete with valves, level indications & accessories as required as per specifications. Dry exhaust manifold with hospital exhaust silencer and catalytic convertor. 12V/24V DC starting system comprising of starter motors: voltage regulator and arrangement for initial excitation complete with suitable nos. of batteries (lead acid type) as required as per specifications. Acoustic and weather proof enclosure with arrangement for fresh air intake for cooling of the engine & alternator, extraction, discharging hot air in to the atmosphere as per specifications. 314 Design, Fabricating, Supply, Installing, Testing & Commissioning of automatic mains failure control including auto by-pass panel, suitable for 500 KVA silent type DG set complete with relays, timers, set of CTs for metering & protection and energy analyser to indicate currents, phase and line voltages, frequency, power factor, KWH, KVARH & provision for overload, short circuit, restricted earth fault, under frequency, control cabling from AMF panel to diesel engine and elsewhere if required, all complete and inter locking including the following: (a) 1 Nos. 630 Amp., 50 kA (Ics=100%Icu), 4 pole, current limiting type MCCB with microprocessor based release with overload setting of 50-100% having adjustable OL & SC. Set at 350A (b) Auto/Manual/Test/Off selector switch (c) 2 Nos. over voltage relay, 2 Nos. reverse power relay and 2 Nos. under voltage relay. (d) 3 Sets of current transformers 15 P 10 accuracy for protection and 15 VA class-I for metering(e) Energy analyser unit to indicate current voltage frequency power factor and KWH(f) Indicating lamps for load on mains and load on set(g) Fuse for instruments(h) Battery charger, complete with transformer/ rectifi er, D.C. voltmeter and ammeter, selector switch for trickle, off and boost and current adjustment.(i) Main supply failure monitor(j) Supply failure timer(k) Restoration timer(l) Control unit with three impulse automatic engine start/stop and failure to start lockout.(m) Impulse counter with locking and reset facility.(n) ON/OFF/Control circuit switch with indicator(o) Audio/Video annunciation for(i) High water temperature(ii) Low lubricating oil pressure(iii) Engine over speed(iv) Engine fails to start(v) Full load/maximum load warning. AMF Panel shall be connected to Main Switch Board incomer with necessary interlocking arrangement to prevent simultaneous switching on of power supplies. All integration between Main Switchboard and AMF Panel is under contractor scope. 315 HT Cable 316 Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium powercable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).3 core 300 sq mm 317 Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required:300 sq. mm 318 Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :300 sq. mm 319 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Above 120 sq. mm and upto 400 sq. mm 320 Air Conditioning Works 321 Supply, Installation, testing and commissioning of 3 x 3 Cassette type Air Conditioner of following capacity and specifications: Consisting of ceiling-mounted type room unit (fan coil) with cordless remote control and one number outdoor condensing unit comprising of energy-efficient suitable rotary compressor for operation on single-phase, 230 V, 50Hz supply, fixing the outdoor unit on a raised platform as per manufacturers recommendation, with R-32/R-410A or equivalent refrigerant and fixing of room (fan coil) unit on ceiling, standard 5 m distance refrigerant copper piping with 13mm nitrile rubber insulation, providing and making interconnection between room & condenser as per site conditions, comprising of 1 dia drain PVC pipe with insulation up to 5 m, canvas connections, full electrical cabling from power plug near indoor unit and to outdoor unit, ODU MS stand, first charge refrigerant gas, suitable stabilizer etc complete as required. (Make: Voltas, Blue Star, Daikin, Hitachi, Carrier or equivalent). Minimum 2 TR 3 Star rated (inverter type AC) as per BEE 322 Supplying additional copper piping of required size and connecting the same to the available piping and extension of the same through 100mm PVC duct inside false ceiling. 323 Electrical Dismantling Works 324 Dismantling of existing outdoor transformer and handing over to client as required by stacking the same within the campus premises, including accessories complete as per direction of engineer-in-charge 325 Dismantling of existing DG set 100 kVA, AMF panel etc and handing over to client as required by stacking the same within the campus premises, including accessories complete as per direction of engineer-in-charge 326 Electrical Works- Fire 327 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured copper power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 70 sq mm 328 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.2 core 6 sq mm with factory made clamp 329 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 16 sq mm with factory made clamp 330 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 35 sq mm with factory made clamp 331 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 6 sq. mm (19mm) 332 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 35 sq. mm (32mm) 333 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 70 sq. mm (38mm) 334 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm) 335 Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. 336 Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required4.00 mm copper conductor ( 8 SWG) 337 Supply of superior quality copper tubular cable socket and making core termination of cables of the following sizes including crimping etc. as required.10 sq mm 338 First Aid Hose reel &Wet Riser system 339 Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required.a.20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585b.20 mm nominal internal dia gun metal globe valve & nozzle. c.Drum and brackets for fixing the equipmets on wall.d.Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket.30 m 340 Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required100 mm dia 341 Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required :2 way-100 mm dia M.S. Pipe 342 Supply and fixing of Air release valve SS body of 25 mm dia (UL Listed). 343 Supply, installation, Testing and Commissioning of Lever operated Ball valves made of Cast iron conforms to IS 5312, at required locations.25 mm dia Make : Kartar/ Atom 344 Supplying and fixing orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required. 345 Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required :Stainless Steel (Grade 304) 346 Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required :Stainless Steel (Grade 304) 347 Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required :Single headed Stainless steel 348 Hose Box - Supply, Installation, Testing and Commissioning of Hose Box -Double door - (cabinet) to accommodate Two pieces of 63 mm dia fire hose along with one pair of 63 mm dia male & female couplings and one branch pipe. The cabinet is made of MS sheet, painted in approved red colour with glass fronted hinged doors and lock &key (UL Listed). 349 Supply and Installation of Fire Brigade Draw-out Collecting head of CI Body having gunmetal 63mm dia instantaneous male draw out confirming to IS:903 suitable to fit on 100mm dia pipe with necessary flanges, rubber gasket, nut & bolts and other items. 350 Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :100mm dia 351 Fire extinguishers 352 Supply &installation of ISI ABC type fire extinguisher of 4 kgs. Make SAFEX/ MINIMAX / CEASEFIRE or equivalent(UL Listed) 353 Supply &installation of CO2 type fire extinguisher of 4.5 kgs. Make SAFEX / MINIMAX / CEASEFIRE or equivalent 354 Supply & installation of water mist type fire extinguisher of 9 liters. Make SAFEX / MINIMAX / CEASEFIRE or equivalent 355 Supplying & Installing of Clean agent based automatic modular fire extinguisher (ceiling mounted) suitable for A,B,C class fires & electrical fires, Capacity- 5Kg 356 Supplying & Installing of Mechanical Foam (Stored Pressure) Type fire extinguisher of 9L capacity with mounting clamp. ISI approved. Make : SAFEX/MINIMAX/CEASEFIRE or equivalent 357 Fire Pumps & Fire Panel 358 Electric driven Main Fire Pump: Supplying, installation, testing and commissioning of Electric driven Main Fire Pump suitable for automatic operation and consisting of following, complete in all respects, as required : (a) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520. (b) Suitable HP Squirrel cage induction motor, TEFC, synchronous speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz, AC supply with IP 55 protection for enclosure, horizontal foot mounted type with Class-F insulation, conforming to IS-325. (c) M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) Suitable cement concrete foundation duly plastered with anti vibration pads.1620 lpm at 56 m Head 359 Supplying, installation, testing and commissioning of diesel engine driven main fire pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Diesel Driven Pump)Horizontal type, multistage, centrifugal pump of cast of iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520.Suitable HP, 1500 RPM water cooled with radiator, diesel engine conforming to relevant IS standard complete with auto starting mechanism, 12 /24 volts electric starting equipment, diesel tank, exhaust pipe extended upto 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications, painted with post office red colour etc. as required.M.S fabricated, common base plate, coupling, coupling guard, foundation bolts etc. as required.Suitable cement concrete foundation duly plastered and with anti vibration pads. 1620 lpm at 56 m Head 360 Supplying, installation, testing and commissioning of electric driven pressurisation pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Jockey Pump)a.Horizontal type, multistage, centrifugal pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS : 1520.b. Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase 50 Hz AC supply with IP 55 class of protection for enclosure, horizontal foot mounted type with Class-F insulation, conforming to IS : 325.c. M.S.fabricated Common base plate, coupling, coupling guard, foundation bolts etc. As required.d. Suitable cement concrete foundation duly plastered and with anti vibration pads. 180 lpm at 56 m Head 361 Fabrication, supply, Installation testing & commissioning of Electrical control panel of cubical construction, floor mounted type, fabricated out of 2mm thick CRCA sheet, compartmentalised with hinged lockable doors, dust and vermin proof, powder coated of approved shade after 7 tank treatment process, cable alley, inter-connection with suitable size copper conductor cable/solid copper strip, having switchgears and accessories, mountings and internal wiring, earth terminals, numbering etc. complete in all respect, suitable for main fire pump, pressurisation pump & diesel pump set complete as per CPWD specification with following in coming and Outgoings, suitable for operation on 415V, 3 phase, 50Hz Ac Supply with enclosure protection class IP 42 as required :INCOMING 250A, 50kA 4 Pole MCCB, Ics=100% Icu rating Digital Voltmeter 0-500V with selector switch Digital Ammeter (0-250 A) with selector switch & CTs etc. LED type RYB phase indicating lamps, ON, OFF, trip indicating lamps Set of Copper Bus Bar 300A OUTGOING (Note : All outgoing feeders for pumps should have digital Ammeter with selector switches, and LED type ON, OFF, trip indicating lamps)Main Fire Pump125 A, 50kA TPN MCCB, Ics=100% Icu, with fully automatic Star/Delta starter suitable for 60 HP pump with overload protection, current sensing type single phase preventor complete with all accessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation.Jockey Pump63 A, 50kA TPN MCCB, Ics=100% Icu, with suitable HP fully automatic Star/Delta starter with overload protection, current sensing type single phase preventor complete with all accessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation.DIESEL ENGINE CONTROLControl for diesel engine comprising - Automatic/Manual selector switch & 3 attempts starting device, timers and relays as required, push buttons, start/stop in manual mode Indicating lamp for high/ Low Lub. Oil pressure, High Water Temp and Engine on indication Battery charger suitable for 12V/24 V DC with boost and trickle selector switch, 0-30 V DC volt meter, and 0- 20 A DC Ammeter All standard relays and accessories for automatic operation of diesel engine System Controller.Designing, Supply, Installation, Testing and commissioning of system controller to control operation of main electric fire pump, diesel pump, Pressurization pump, Terrace pump in sequence as per specification consisting of relays, timers. Sensors, annunciation window for fault indication, complete as per specification 362 Supplying & Installation of suitable flexible coupling/connection to fix at the suction and deliverys side of the fire pumps.dia 150mm 363 Supplying & Installation of suitable flexible coupling/connection to fix at the suction and deliverys side of the fire pumps.dia 80mm 364 Supply and Installation of 12V DC, 200Ah maintenace free battery suitable for Diesel Engine driven fire pump operation with required connect cable set, battery stand. 365 Supplying & Installation of suitable flexible coupling/connection to fix at the suction and deliverys side of the fire pumps.dia 100mm 366 Signages 367 Supply and fixing in position Exit Signages photo luminescent type with indication arrows and letters Exit/Fire Exit/ Staircase/FIRE/Fire Station/Fire Fighting Equipment/Fire Duct/ Fire Extinguisher/ Floor/Fire Command Centre/Fire Pump Room/ No Smoking / Danger/ Call point / Sounder Identification Numbers (Ground/ 1st/2nd)/ In case of the fire do not use lift, use stairs and other mandatory signages recommended by Fire Departments having dimension 30 cm x 15 cm complete inculding fixing mechanism. 368 Supplying and Installing in position the signages approved by Kerala state fire service - of minimum size 1ft x 1.5ft made out of PVC rigid sheet 3mm thick with computer cut PVC non- reflective self adhesive imported vinyl painted on the front of PVC rigid sheet complete with wall mounting arrangements with mirror screws. with lettering- ASSEMBLY AREA 369 Signboards: Supply and Installation of Fire Escape Plan with fire fighting equipment location, exit in A3 Foam sheet with plastic lamination with necessory accessories to fix it on wall. 370 Supply and fixing in position & Fire Order& signage in suitable size made of high quality PVC foam sheet with photo luminescent lamination to make it glow automatically in the dark, with suitable arrangement to fix it on wall. 371 Supplying & fixing in position Assembly Point sigange in suitable size on aluminium composite panel with suitable stand to fix it on open area outside building. Assembly Point 372 Terrace pump 373 Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump)a.Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical confirming to IS : 1520b. Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horiziontal foot mounted type with Class-F insulation, conforming to IS-325.c. M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required.d. Suitable cement concrete foundation duly plastered and with anti vibration pads. 450 lpm at 35 m Head 374 Design, Supply, Installation, Testing, and Commissioning of an Automatic Terrace Fire Pump Panel, including:- IP54-rated enclosure with powder-coated CRCA sheet steel.- 32A 16kA MCCB, 15 HP-rated pump 3P contactor, overload relay, and pressure switch for automatic pump operation.- Auto/Manual selector switch, START/STOP push buttons, hooter, timer, and protection features (dry-run, phase failure, etc.).- Indicators (Power ON, Pump Running, Fault, Low Pressure), meters (Voltmeter, Ammeter with selector switches).- Copper wiring, termination, and provision for cable glands.- Installation, onsite calibration, and full functional testing for pressure-based automation. 375 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 16 sq mm with factory made clamp 376 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm) 377 Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required100 mm dia 378 Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :100mm dia 379 Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange.100mm dia 380 Pressure Guage-Supply, Installation, Testing and Commissioning of pressure guage, 4 & dial, 0 - 200 psi range 3/8 BSP weather proof with stainless steel internals, siphon tube including fittings etc (UL Listed). Make: H Guru/Pointer 381 Supply, installation, Testing and Commissioning of Lever operated Ball valves made of Cast iron conforms to IS 5312, at required locations (UL Listed).20 mm dia Make : Kartar/ Atom 382 Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required4.00 mm copper conductor ( 8 SWG) 383 Supply of superior quality copper tubular cable socket and making core termination of cables of the following sizes including crimping etc. as required.10 sq mm 384 Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required 385 Above Ground Piping 386 Providing, laying, testing & commissioning of C class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :100 mm dia 387 Providing, laying, testing & commissioning of C class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :25 mm dia 388 Providing, laying, testing & commissioning of C class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :80 mm dia 389 Providing, laying, testing & commissioning of C class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :250 mm dia (wall thickness 6.3 mm) 390 Providing, laying, testing & commissioning of C class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :150 mm dia 391 Providing, laying, testing & commissioning of C class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :200 mm dia (wall thickness 6.3 mm) 392 Supply and Installation of 80mm dia M.S. &C& Class Diesel Engine exhaust pipe duly insulated with 50mm thick Glass wool with 1mm thick aluminium sheet cladding with bellows, flexible joint, necessary support, making hole in brick wall for pipe installation.Pipe dia 80mm 393 Underground piping 394 Supply, Installation, Testing and Commissioning of MS C class ERW pipes with ISI Mark complete including cutting and jointing as per the requirements of standards, welding using high quality welding electrodes for pipe. supporting the pipes using Channels or Angles or structures at required intervals as specified for fire fighting work. Piping shall have one coat of anticorrossive zinc chromate industrial primer and two coats of IS approved colour code. All pipes are with ISI mark (IS 1239/3589)Pipes of required dimensions (length and dia) need to fabricated by the vendor by cutting/welding pipes of standard dimensions. length of each type( pipe diameter) should be fixed by the vendor after visiting the site and factory building. The pipe shall be laid direct in ground (75 cm below ground level) including excavation and refilling the trench and covering with 3 mm tar sheet. Pipe size 150 mm. Make - TATA / JINDAL 395 Supply, Installation, Testing and Commissioning of MS C class ERW pipes with ISI Mark complete including cutting and jointing as per the requirements of standards, welding using high quality welding electrodes for pipe. supporting the pipes using Channels or Angles or structures at required intervals as specified for fire fighting work. Piping shall have one coat of anticorrossive zinc chromate industrial primer and two coats of IS approved colour code. All pipes are with ISI mark (IS 1239/3589)Pipes of required dimensions (length and dia) need to fabricated by the vendor by cutting/welding pipes of standard dimensions. length of each type( pipe diameter) should be fixed by the vendor after visiting the site and factory building. The pipe shall be laid direct in ground (75 cm below ground level) including excavation and refilling the trench and covering with 3 mm tar sheet. Pipe size 200 mm. Make - TATA / JINDAL 396 Supply, Installation, Testing and Commissioning of MS C class ERW pipes with ISI Mark complete including cutting and jointing as per the requirements of standards, welding using high quality welding electrodes for pipe. supporting the pipes using Channels or Angles or structures at required intervals as specified for fire fighting work. Piping shall have one coat of anticorrossive zinc chromate industrial primer and two coats of IS approved colour code. All pipes are with ISI mark (IS 1239/3589)Pipes of required dimensions (length and dia) need to fabricated by the vendor by cutting/welding pipes of standard dimensions. length of each type( pipe diameter) should be fixed by the vendor after visiting the site and factory building. The pipe shall be laid direct in ground (1m below ground level) including excavation and refilling the trench and covering with 3 mm tar sheet. Pipe size 100 mm. Make - TATA / JINDAL 397 Valves, measuring devices & switches 398 Supplying, fixing, testing & commissioning of double flanged sluice valve of rating PN 1.6 with non rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 780 of following sizes as required:200mm dia 399 Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required80 mm dia 400 Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required100 mm dia 401 Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required150 mm dia 402 Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :80mm dia 403 Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :150mm dia 404 Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange.150mm dia 405 Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and painting with synthetic enamel paint of approved shade as required. 406 Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required 407 Pressure Gauge-Supply, Installation, Testing and Commissioning of pressure gauge, 4 dial, 0 - 200 psi range 3/8 BSP weather proof with stainless steel internals, siphon tube including fittings etc (UL Listed). Make: H Guru/Pointer 408 Supply and fixing of Air release valve Brass body of 25 mm dia (UL Listed) following IS standards, with required pressure rated. 409 Supply, installation, Testing and Commissioning of Lever operated Ball valves made of Cast iron conforms to IS 5312, at required locations.25 mm dia Make : Kartar/ Atom 410 Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :100mm dia 411 MOEFA system, Automatic Detection & Fire Alarm System 412 Supplying, installing, testing and commissioning approved make Microprocessor based Multi-loop, Networkable Addressable Fire Alarm Control Panel with minimum 600 characters LCD display, 4000 trouble events including1000 alarm log history events, Self Programmable alphanumeric keypad for programming. The panel should be equipped with sufficient numbers of loops considering 20% spare capacity in each loop and shall be extendable upto 10 Loops. Each loop shall have a capacity of minimum 125 detectors & 125 other devices exculding 20% spare. The panel shall work in degrade mode in case of CPU failure, Products not having this feature may offer Redundant CPU. Four access levels, flash EPROM, 240 volts AC power supply, automatic battery charger, 24 volts sealed lead acid batteries sufficient for 24 hours normal working and 30 mins in alarm condition with the charging capacity of 200AH. The panel shall be capable of self programing without any dependancy on dongle or programming software. Quoted rate shall include supply of necessary software & hardware for progamming the panel with all necessary licence. Panel shall have Modbus over IP protocol for future integration with BMS. However, for present arrangement FA system will be standalone with 24x7 monitoring. The panel shall be capable of connecting to the cloud platform/solution. Complied to meet UL864, 10th Edition 6 Loop Networkable Addressable Fire Alarm Control Panel(Make: Honeywell or Equivalent) 413 Supplying, installation, testing & commissioning of addressable fire control module complete as required. 414 Supplying, installation, testing & commissioning of addressable manual call point complete as required. 415 Supplying, installation, testing & commissioning of addressable horn cum strobe complete as required. 416 Supplying, installation, testing & commissioning of intelligent analog addressable photothermal detector complete with mounting base complete as required. 417 Supplying, installation, testing & commissioning of fault isolator complete with base as required. 418 Supplying, Installation, testing & commissioning of external power supply unit provides regulated and filtered 24 VDC power for hooter operation.Battery backup with built in charging. 419 CABLING & WIRING Supplying & laying of 2x1.5 sq mm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required. 420 Miscellaneous 421 Preparation of initial and final drawings, submission to Panchayath, Municipality, KSEB, Electrical Inspectorate, Kerala Water Authority, State Pollution Control board, Fire Department, Factories and Boilers and other agencies if any for getting approval, sanction and No Objection Certificate for building permit and completion from Fire Department and other department. Quoted rate shall be excluding statutory fee (All statutory fees shall be borne by Client-actual statutory fees shall be reimbursed on submission of original bill/challans from authorities).
Contract Date: Jul 17, 2025 Contract Value : 11.48 Crore
Boards / Undertakings / PSU No of Bidders 1
20.
Power #10383050 Price Bid
Tender For Annual Civil & Electrical M&R Work for Residential Building Situated At 20-Clive Road Hydel Colony, Prayagraj - Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. for all kinds of soil. 2 Supplying and filling in plinth withsand under floors, including watering, ramming, consolidating and dressing complete. 3 Surface dressing of the ground including removing vegetation and in-equalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m. for all kinds of soil. 4 Excavating, supplying, stacking and filling of local earth by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in foundation trenches, plinth, sides of foundation etc. complete for all lift. 5 Providing and laying in position cement concrete of grade 1:1½:3 (1 Cement: 1½ coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) excluding the cost of centering and shuttering - All work up to plinth level : 6 Providing and laying in position cement concrete of grade1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) excluding the cost of centering and shuttering - All work up to plinth level : 7 Providing and laying in position cement concrete of grade 1:5:10 (1 cement : 5 fine sand derived from natural sources : 10 graded stone aggregate 40 mm nominal size derived from natural sources) excluding the cost of centering and shuttering - All work up to plinth level : 8 Providing and laying cement concrete 1:1½:3 (1 Cement: 1½ coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) in kerbs, steps and the like at or near ground level excluding the cost of centering, shuttering and finishing. 9 Providing and fixing up to floor five level precast cement concrete 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20mm nominal size derived from natural sources) string or lacing courses, copings, bed plates, anchor blocks, plain window sills, shelves, louvers, steps, stair cases, etc., including hoisting and setting in position with cement mortar 1:3 (1 Cement : 3 coarse sand), cost of required Centering complete. 10 Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 12.5mm nominal size derived from natural sources) 11 Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturers specification. 12 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. 13 Providing and laying in positiongrade 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 14 Providing and laying in positiongrade 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 15 Reinforced cement concrete 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 16 Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). 17 Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete 18 Centering and shuttering including strutting, propping etc. and removal of form for Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. 19 Centering and shuttering including strutting, propping etc. and removal of form forSuspended floors, roofs, landings, balconies and access platform 20 Centering and shuttering including strutting, propping etc. and removal of form for Shelves (Cast in situ) 21 Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers 22 Centering and shuttering including strutting, propping etc. and removal of form for Columns, Pillars, Piers, Abutments, Posts and Struts 23 Centering and shuttering including strutting, propping etc. and removal of form for Stairs, (excluding landings) except spiral-staircases 24 Centering and shuttering including strutting, propping etc. and removal of form for Spiral staircases (including landing) 25 Centering and shuttering including strutting, propping etc. and removal of form for Small lintels not exceeding 1.5 m clear span, moulding as in cornices, window sills, string courses, bands, copings, bed plates, anchor blocks and the like 26 Centering and shuttering including strutting, propping etc. and removal of form for Small surfaces such as cantilever ends, brackets and ends of steps, caps and bases to pilasters and columns and the like 27 Centering and shuttering including strutting, propping etc. and removal of form for Weather shade, Chajjas, corbels etc., including edges 28 Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platform with water proof ply 12 mm thick 29 Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers with water proof ply 12 mm thick 30 Mild steel and Medium Tensile steel bars for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. 31 Mild steel and Medium Tensile steel bars for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. 32 Smooth finishing of the exposed surface of R.C.C. work with 6 mm thick cement mortar 1:3 (1 Cement : 3 fine sand). 33 Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections. 34 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in Cement mortar 1:6 (1 cement : 6 coarse sand) 35 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) 36 Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundations and plinth in cement mortar 1:4 (1 cement : 4 coarse sand) 37 Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. Cement mortar 1:4 (1 cement :4 coarse sand) 38 Providing and fixing 18 mm thick Granite stone slab of colour black, Cherry/Ruby red gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels (Area of slab over 0.50 sqm) 39 Providing edge moulding to 18 mm thick Granite workcounters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. 40 Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. 41 Providing and fixing plywood 4 mm thick, one side decorative veneer conforming to IS: 1328 (type-1), for plain lining / cladding with necessary screws, including priming coat on unexposed surface with : 42 Providing and fixing 4mm thick coir veneer board, ISI marked IS : 14842, plain lining with necessary screws, priming coat on unexposed surface etc., complete. 43 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 44 Providing Second class teak wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately). 45 Providing and fixing 2nd class teak wood size 50x12 mm moulded beading to door and window frames with iron screws, plugs and priming coat on unexposed surface etc. complete : 46 Providing and fixing Second class teak wood panelled or panelled and glazed 30 mm thick shutters for doors, windows and clerestory windows, fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note:- Butt hingesand necessary screwsshall be paid separately) 47 Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. 48 Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISi, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete. 49 Providing and fixing30mm thick glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes (weight not less than 10 kg per sqm) fixing with ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws.(Kiln seasoned and chemically treated hollock wood) 50 Providing and fixing35mm thick glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes (weight not less than 10 kg per sqm) fixing with ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws.(Kiln seasoned selected planks of sheesham wood) 51 Providing and fixing30mm thick glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes (weight not less than 10 kg per sqm) fixing with ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws.(Kiln seasoned selected planks of sheesham wood) 52 Providing and fixing30mm thick Panelled or panelled & glazed shutters for cup board using 4 mm thick float glass panes (weight not less than 10 kg per sqm) fixing with ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws.(Second class teak wood including ISI marked anodised aluminium butt hinges with necessary screws) 53 Providing and fixing ISI marked 35mm thick flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters ( including ISI marked Stainless Steel butt hinges with necessary screws) 54 Providing and fixing ISI marked 30mm thick flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters ( including ISI marked Stainless Steel butt hinges with necessary screws) 55 Providing and fixing ISI marked 35mm thick flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters ( including ISI marked Stainless Steel butt hinges with necessary screws) 56 Extra for Providing and fixing flush doors with On one side only decorative veneering instead of non decorative ISI marked flush door shutters conforming to IS: 2202 (Part I) 57 Providing and fixing 12mm dia chromium plated brass curtain rod having wall thickness of 1.25mm with two chromium plated brass brackets fixed with C.P. brass screws andPVC sleeves etc., wherever necessary complete : 58 Providing and fixing 20mm dia chromium plated brass curtain rod having wall thickness of 1.25mm with two chromium plated brass brackets fixed with C.P. brass screws andPVC sleeves etc., wherever necessary complete : 59 Providing and fixing 25mm dia chromium plated brass curtain rod having wall thickness of 1.25mm with two chromium plated brass brackets fixed with C.P. brass screws andPVC sleeves etc., wherever necessary complete : 60 Providing and fixing 20mm dia (heavy type) nickel plated M.S. pipe curtain rods with nickel plated brackets : 61 Providing and fixing 25mm dia (heavy type) nickel plated M.S. pipe curtain rods with nickel plated brackets : 62 Providing and fixing hard drawn steel wire fabric 75x25 mm mesh of weight not less than 7.75 Kg per sqm to window frames etc. including 62x19 mm beading of second class teak wood and priming coat with approved steel primer all complete. 63 Providing and fixing 125x65x2.12 mm ISI marked IS:1341 oxidised M.S. pressed butt hinges with necessary screws etc. complete. (Copper oxidised as per IS 1378) 64 Providing and fixing 100x58x1.90 mmISI marked IS:1341 oxidised M.S. pressed butt hinges with necessary screws etc. complete. (Copper oxidised as per IS 1378) 65 Providing and fixing 75x47x1.70 mmISI marked IS:1341 oxidised M.S. pressed butt hinges with necessary screws etc. complete. (Copper oxidised as per IS 1378) 66 Providing and fixing 50x37x1.50 mmISI marked IS:1341 oxidised M.S. pressed butt hinges with necessary screws etc. complete. (Copper oxidised as per IS 1378) 67 Providing and fixing 150 mm ISI marked oxidised M.S. single acting spring hinges with necessary screws etc. complete (Copper oxidised as per IS 1378) 68 Providing and fixing 125 mm ISI marked oxidised M.S. single acting spring hinges with necessary screws etc. complete (Copper oxidised as per IS 1378) 69 Providing and fixing 100 mm ISI marked oxidised M.S. single acting spring hinges with necessary screws etc. complete (Copper oxidised as per IS 1378) 70 Providing and fixing 250x16 mm ISI marked oxidised M.S. sliding door bolts with nuts and screws etc. complete (Copper oxidised as per IS 1378) 71 Providing and 250x10 mm fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete (Copper oxidised as per IS 1378) 72 Providing and 200x10 mm fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete (Copper oxidised as per IS 1378) 73 Providing and 150x10 mm fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete (Copper oxidised as per IS 1378) 74 Providing and 100x10 mm fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete (Copper oxidised as per IS 1378) 75 Providing and fixing ISI marked 85x42 mm oxidised M.S. pull bolt lock conforming to IS : 7534 with necessary screws bolts, nut and washers etc. complete (Copper oxidised as per IS 1378). 76 Providing and fixing 125 mm ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete (Copper oxidised as per IS 1378) 77 Providing and fixing 100 mm ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete (Copper oxidised as per IS 1378) 78 Providing and fixing 75 mm ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete (Copper oxidised as per IS 1378) 79 Providing and fixing 150 mm oxidised M.S. hasp and staple (safety type) conforming to IS : 363 with necessary screws etc. complete (Copper oxidised as per IS 1378) 80 Providing and fixing 115 mm oxidised M.S. hasp and staple (safety type) conforming to IS : 363 with necessary screws etc. complete (Copper oxidised as per IS 1378) 81 Providing and fixing 90 mm oxidised M.S. hasp and staple (safety type) conforming to IS : 363 with necessary screws etc. complete (Copper oxidised as per IS 1378) 82 Providing and fixing 300 mm (weighing not less than 330 grams) oxidised M.S. casement stays (straight peg type) with necessary screws etc. complete (Copper oxidised as per IS 1378) 83 Providing and fixing 125mm special quality bright finished brass handles with screws for cupboard or ward robe locks with four levers of approved quality including necessary screws etc. complete. 84 Providing and fixing 100mm special quality bright finished brass handles with screws for cupboard or ward robe locks with four levers of approved quality including necessary screws etc. complete. 85 Providing and fixing 75mm special quality bright finished brass handles with screws for cupboard or ward robe locks with four levers of approved quality including necessary screws etc. complete. 86 Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete. 87 Providing and fixing Triple strip vertical type magnetic catcher of approved quality in cupboard / ward robe shutters, including fixing with necessary screws etc. complete. 88 Providing and fixing Double strip (horizontal type) magnetic catcher of approved quality in cupboard / ward robe shutters, including fixing with necessary screws etc. complete. 89 Providing and fixing factory made uPVC door frame made of uPVC extruded sections having an overall dimension as below (tolerance ±1mm),with wall thickness 2.0 mm (± 0.2 mm), corners of the door frame to be Jointed with galvanized brackets and stainless steel screws, joints mitred and Plastic welded. The hinge side vertical of the frames reinforced by galvanized M.S. tube of size 19 X 19 mm and 1mm (± 0.1 mm) wall thickness and 3 nos. stainless steel hinges fixed to the frame complete as per manufacturer’s specification and direction of Engineer- in-charge (Extruded section profile size 48x40 mm) 90 Providing and fixing factory made uPVC door frame made of uPVC extruded sections having an overall dimension as below (tolerance ±1mm),with wall thickness 2.0 mm (± 0.2 mm), corners of the door frame to be Jointed with galvanized brackets and stainless steel screws, joints mitred and Plastic welded. The hinge side vertical of the frames reinforced by galvanized M.S. tube of size 19 X 19 mm and 1mm (± 0.1 mm) wall thickness and 3 nos. stainless steel hinges fixed to the frame complete as per manufacturer’s specification and direction of Engineer- in-charge (Extruded section profile size 42x50 mm) 91 Providing and fixing 12 mm thick Fire retardant plywood conforming to IS: 5509 panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick. 92 Providing and fixing cup board shutters 25 mm thick, with Pre-laminated flat pressed three layer particle board or graded wood particle board IS: 12823 marked, exterior grade (Grade l Type ll), having one side decorative lamination and other side balancing lamination, including IInd class teak wood lipping of 25 mm wide x12 mm thick with necessary screws and bright finished stainless steel piano hinges, complete as per direction of the Engineer-in-Charge 93 Providing and fixing aluminum U beading of required size to Pre-laminated/flush door shutter, including fixing etc. complete as per direction of Engineer-in-charge. 94 Providing and fixing casement handle made of zinc alloyed (white powder coated) for uPVC casement window with necessary screws etc. complete. 95 Providing and fixing zinc alloyed (white powder coated) touch lock for uPVC sliding window with necessary screws etc. complete. 96 Providing and fixing steel roller for uPVC sliding window with necessary screws etc. complete. 97 Providing and fixing steel roller for uPVC sliding door with necessary screws etc. complete. 98 Providing and fixing steel (white power coated) crescent lock for uPVC sliding window/ door with necessary screws etc. complete. 99 Providing and fixing 18mm thick both sides Pre-laminated cement bonded wood particle board as per IS : 15786:2008 of approved brand and shade with suitable full threaded steel screws etc. in partitions, boxes, shelves, racks and cupboard, kitchen cabinet under kitchen counter etc. all complete as per direction of Engineer-in-charge (Note: Fittings to be paid separately). 100 Providing and fixing 6mm thick both sides Pre-laminated cement bonded wood particle board as per IS : 15786:2008 of approved brand and shade with suitable full threaded steel screws etc. on the backing of racks, drawer, cupboard, kitchen cabinet under kitchen counter etc. all complete as per direction of Engineer-in-charge. 101 Providing and fixing cupboard shutter with 19mm thick one side decorative and other side balancing lamination factory pressed BWP grade marine ply as per IS 710 of approved brand including 2mm thick PVC edge banding tape with hot glue by edge bending machine etc. with auto closing spring loaded hinges (hydraulic type) etc. complete as per direction of Engineer-in-charge.(Payment of providing and fixing auto closing hinges shall be paid separately) 102 Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. 103 Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer. 104 Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer.(Using M.S. angels 40x40x6 mm for diagonal braces) 105 Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). 106 Providing and fixing angle iron frames for doors, windows and ventilators of mild steel Angle sections of size 35x35x5 mm, joints mitred and welded by angle iron 35x35x5 mm or 35x 5 mm flat pieces to the existing T-iron frame or to the wall with dash fastener,including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer, all complete as per the direction of Engineer-In-charge. 107 Brick on edge flooring with bricks of class designation 7.5 on a bed of 12 mm cement mortar with 1:6 (1cement : 6 coarse sand) including filling the joints with same mortar, with common burnt clay non modular bricks: 108 Dry brick on edge flooring in required pattern with bricks of class designation 7.5 on a bed of 12 mm mud mortar, including filling joints with Jamuna sand, with common burnt clay non modular bricks. 109 40 mm thick with 20 mm nominal size stone aggregate Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. 110 18 mm thick Cement plaster skirting up to 30 cm height, with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement. 111 Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete. 112 Cement concrete pavement with 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete. 113 25 mm thick Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 114 Deduct for not using 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand) bedding in laying of floor tiles and jointing with grey cement slurry @ 3.3 kg/ sqm. 115 Fixing glazed/ Ceramic/ Vitrified floor tiles with cement based high polymer modified quick-set tile adhesive (Water based) conforming to IS: 15477, in average 3mm thickness. 116 Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. 117 Providing and fixing 1st quality ceramic glazed floor tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. 118 Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sq.m including pointing the joints with white cement and matching pigments etc., complete. 119 Providing and laying vitrified floor tiles Size 600x600 mm(thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqmincluding grouting the joints with white cement and matching pigments etc., complete. 120 Providing 1 mm thick with zinc coating not less than 275 gm/ m² corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 121 Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. 122 Providing & fixing 0.56 mm, Aluminium Color coated troughed profile with center to center pitch of 200 mm, depth of 32 mm, overall profile width1092 mm, cover width 1000mm at all heights, levels and locations colour finish Aluminium alloy roofing sheets of alloyIS designation31500, temper Hx8 conforming to IS 737 and dimensions as per IS code 2676 with characteristics of good formability and corrosion resistance. The profile sheets shall be fixed to truss members in slope or required pitch or curvature with Hex cap headed self drilling/tapping Stainless steel screws M6, 50 mm long with 3 mm EPDM seal washer etc. all inclusive of labour, scaffolding, T&P and sundries etc. complete as per directions of the Engineer-In-Charge. (Cost of truss/frame work shall be paid separately). 123 Providing and fixing Precoated/mill finish aluminium Ridges plain (500- 600mm) of Pre-coated colour or mill finishAluminium Roofing Accessories in 0.71 mm thickness ,Alloy 31500 (IS designation) [Aluminium Alloy (AA) 3004 (ISO designation)]For color, coating shall be 5-7 microns epoxy primer on both sides of the sheet and polyester top coat 15-18 microns, using self drilling/tapping SS screws of size 6 x 50mm with 3mm thick EPDM seal and SS plain washer complete : 124 Providing 10 mm thick plaster of Paris (gypsum anhydrous) Flat surfaces ceiling up to a height of 5 m above floor level, over first class kail wood strips 25x6 mm with 10 mm gap in between and reinforced with rabbit wire mesh fixed to wooden frame (frame work to be paid separately): 125 12.5 mm thick fully Perforated Gypsum Board tile made from plasterboard having glass fibre conforming to IS: 2095 part I, of size 595x595 mm, having perforation of 9.7x9.7 mm at 19.4 mm c/c with center borders of 48 mm and the side borders of 30 mm, backed with non woven tissue on the back side, having an NRC (Noise Reduction Coefficient) of 0.79, with 50 mm resin bonded glass wool backing. 126 12 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) 127 12 mm cement plaster of mix :1:6 (1 cement: 6 fine sand) 128 12 mm cement plaster finished with a floating coat of neat cement of mix : 1:3 (1 cement: 3 fine sand) 129 12 mm cement plaster finished with a floating coat of neat cement of mix : 1:4 (1 cement: 4 fine sand) 130 6 mm cement plaster of mix : 1:3 (1 cement : 3 fine sand) 131 Neat cement punning. 132 Distempering with 1st quality acrylic distemper (ready mixed) New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than50 gram/litre of approved manufacturer and of required shade and colour all complete to achieve even shade and colour : 133 Finishing walls for New work (Two or more coats applied @ 3.84 kg/10 sqm) with water proofing cement paint of required shade : 134 Finishing walls for New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) with Acrylic Smooth exterior paint of required shade : 135 Finishing walls for New work (Two or more coats applied @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm. with ready mixed Premium acrylic emulsion paint (Company Depot Tinted) having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shadewith silicon additives. 136 With ready mixed aluminium primer of approved brand and manufacture on resinous wood and plywood 137 With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works 138 With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel work (second coat) 139 Painting (two or more coats) on 100mm diameter rain water, soil waste and vent pipes and fittings with synthetic enamel paint of approved brand and manufacture and required colour over a priming coat of approved steel primer on new work. 140 Painting (two or more coats) on 150mm diameter rain water, soil waste and vent pipes and fittings with synthetic enamel paint of approved brand and manufacture and required colour over a priming coat of approved steel primer on new work. 141 Painting Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : 142 Polishing on New wood work with ready mixed wax polish of approved brand and manufacture : 143 Lettering with black Japan paint of approved brand and manufacture 144 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 145 Distempering for Old work (one or more coats) with 1st quality acrylic distemper (ready mixed) having VOC (Volatile Organic Compound ) content less than 50 gram/ litre, of approved brand and manufacturerincluding applying additional coats wherever required to achieve even shade and colour 146 Applying priming coats with water thinnable cement primer on wall surface having VOC content less than 50 grams/litre of approved brand and manufacture. 147 6 mm plaster on cement concrete or reinforced cement concrete work with white cement based polymer modified self curing mortar of approved make as per the direction of Engineer-In-Charge. 148 Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete 149 Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. 150 Polishing on Old wood work with ready made wax polish of approved brand and manufacture : 151 Painting (one or more coats) with black Japan paint of approved brand and manufacture to give an even shade. 152 Finishing walls for Old work (Two or more coat applied @ 1.67 ltr/ 10 sqm) on existing cement paint surface with Acrylic Smooth exterior paint of required shade : 153 Repairs to plaster of thickness 12 mm to 20 mm With cement mortar 1:4 (1 cement : 4 fine sand) in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge. 154 Fixing Door chowkhats in existing opening including embedding chowkhats in floors or walls cutting masonry for holdfasts, embedding hold fasts in cement concrete blocks of size 15 x 10 x 10 cm with cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size), painting two coats of approved wood preservative to sides of chowkhats and making good the damages to walls and floors as required complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge. 155 Fixing chowkhat in existing opening in brick/ RCC wall with dash fasteners/Chemical fasteners of appropriate size (3 nos on Each vertical member of door chowkhat and 2 nos on Each vertical member of window chowkhats), including Cost of dash fasteners/ chemical fastener. 156 Making the opening For door/ window/ clerestory window in brick masonry including dismantling in floor or walls by cutting masonry and making good the damages to walls, flooring and jambs complete, to match existing surface i/c disposal of mulba/ rubbish to the nearest municipal dumping ground, all complete as per direction of Engineer-in-Charge. 157 Renewing Float glass panes of nominal thickness 4 mm (weight not less than 10kg/sqm) with putty and nails wherever necessary including racking out the old putty: 158 Renewing Float glass panes of nominal thickness 5 mm (weight not less than 12.5kg/sqm) with putty and nails wherever necessary including racking out the old putty: 159 Renewal of old putty of glass panes (length) 160 Refixing old glass panes with putty and nails 161 Fixing old glass panes with wooden fillets (excluding cost of fillets) 162 Renewing bottom rail and/or top runner of collapsible gate including making good all damages and applying priming coat of zinc chromate yellow primer of approved brand and manufacturer. 163 Pumping out water caused by springs, tidal or river seepage, broken water mains or drains and the like. 164 Providing and fixing 20 mm diameter. brass curtain rods ofwall thickness 1.25 mm with two brass brackets fixed with brass screws and wooden plugs etc. wherever necessary complete. 165 Repair to plaster of thickness 12mm to 20 mm in patches of area 2.5 sqm and under, including cutting the patch in proper shape, raking out joints and preparing plastering the wall surface with white cement based polymer modifiedself curing mortar, including disposal of rubbish, all completeas per the direction of Engineer-In-Charge. 166 Cleaning and desilting of gully trap chamber, including removal of rubbish mixed with earth etc. and disposal of same, all as per the direction of Engineer-in-charge. 167 Disconnecting damaged overhead/terrace PVC water storage tankof any size from water supply line and removing from the terrace including shifting at ground level as per direction of Engineer-in-charge. 168 Providing & fixing Orissa pattern W.C Pan of size 580x440 mm White vitreous china water closet squatting pan (Indian type) along withS or P trap including dismantling of old WC seat and S or P trap at site complete with all operations including all necessary materials, labour and disposal of dismantled material i/c malba, all complete as per the direction of Engineer-in charge. 169 DismantlingW.C.Pan of all sizes including disposal of dismantled materials i/c malba all complete as per directions of Engineer-in-Charge. 170 Dismantling 15 to 40 mm dia G.I. pipe including stacking of dismantled pipes (within 50 Metres lead) as per direction of Engineer-in-Charge.(a) Internal Work- Exposed on wall 171 Taking out existing wooden door shutter, repair by cutting, painting etc. and refixing of repaired door shutters to existing door frames, including replacement of hinges with screws, etc. as required, all complete as per the direction of the Engineer-in-charge. 172 Demolishing lime concrete manually/ by mechanical means and disposal of material within 50 Metres lead as per direction of Engineer- in-charge. 173 Demolishing Nominal cementconcrete 1:3:6 or richer mix (i/c equivalent design mix manually/ by mechanical means including disposal of material within 50 Metres lead as per direction of Engineer - in - charge. 174 Demolishing Nominal cementconcrete 1:4:8 or leaner mix (i/c equivalent design mix manually/ by mechanical means including disposal of material within 50 Metres lead as per direction of Engineer - in - charge. 175 Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 Metres lead as per direction of Engineer - in- charge. 176 Demolishing brick work in cement mortar manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 Metres lead as per direction of Engineer-in-charge. 177 Removing mortar from bricks in From brick work in cement mortar and cleaning bricks including stacking within a lead of 50 m (stacks of cleaned bricks shall be measured): 178 Dismantling doors, windows and clerestory windows (steel or wood) shutter Of area 3 sq. Metres and below including chowkhats, architrave, holdfasts etc. complete and stacking within 50 Metres lead : 179 Dismantling doors, windows and clerestory windows (steel or wood) shutter Of area beyond 3 sq. Metres including chowkhats, architrave, holdfasts etc. complete and stacking within 50 Metres lead : 180 Taking out doors, windows and clerestory window shutters (steel or wood) Of area 3 sq. Metres and belowincluding stacking within 50 Metres lead : 181 Taking out doors, windows and clerestory window shutters (steel or wood) Of area beyond 3 sq. Metres including stacking within 50 Metres lead : 182 Dismantling For thickness of tiles 10 mm to 25 mmwork in floors and roofs laid in cement mortar including stacking material within 50 Metres lead. 183 Dismantling For thickness of tiles above 25 mm and up to 40 mmwork in floors and roofs laid in cement mortar including stacking material within 50 Metres lead. 184 Demolishing dry brick pitching in floors, drains etc. including stacking of serviceable material and disposal of unserviceable material within 50 Metres lead : 185 Dismantling G.S. Sheetroofingincludingridges,hips,valleysandguttersetc., and stacking the material within 50 Metres lead of: 186 Dismantling Asbestos Cement sheetroofingincludingridges,hips,valleysandguttersetc., and stacking the material within 50 Metres lead of: 187 Dismantling tiled roofing with battens, boarding etc. complete includingstackingofserviceablematerialanddisposalofunserviceable material within 50 Metres lead. 188 Dismantlingbarbedwireorflexiblewireropeinfencingincludingmaking rolls and stacking within 50 Metres lead. 189 Dismantling40 mm thick precast concrete orstone slabsin walls, partition walls etc. including stacking within 50 Metres lead : 190 Dismantling40 mm to 75mmthick precast concrete orstone slabsin walls, partition walls etc. including stacking within 50 Metres lead : 191 Dismantling cement asbestos or other hard board ceiling or partition wallsincludingstackingofserviceablematerialsanddisposalof unserviceable materials within 50 Metres lead. 192 Dismantling of flushing cistern of all types(C.I./PVC/Vitrious China) includingstackingofusefulmaterialsnearthesiteanddisposalofunserviceable materials within 50 Metres lead. 193 Dismantling old plaster or skirting raking out joints and cleaning the surfaceforplasterincludingdisposalofrubbishtothedumping ground within 50 Metres lead. 194 Dismantlingaluminium/Gypsumpartitions,doors,windows,fixed glazing and false ceiling including disposal of unserviceable material andstackingofserviceablematerialwithin50metersleadas directed by Engineer-in-charge. 195 Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping groundorasapprovedbyEngineer-in-charge,beyond50minitial lead, for all leads including all lifts involved. 196 Cuttingroadandmakinggoodthesameincludingsupplyofextra quantities of materials i.e. aggregate, moorum screening, red bajri and labour (required.bituminous portion) 197 Paintingroadsurfacemarking for New work (Two or more coats) withadequatenosofcoatstogive uniform finish with ready mixed road marking paint conforming to IS : 164, on bituminous surface in white/yellow shade, including cleaning thesurfaceofalldirt,scales,oil,greaseandforeignmaterialetc. complete. 198 Paintingroadsurfacemarking for Old work (One or more coats) withadequatenosofcoatstogive uniform finish with ready mixed road marking paint conforming to IS : 164, on bituminous surface in white/yellow shade, including cleaning thesurfaceofalldirt,scales,oil,greaseandforeignmaterialetc. complete. 199 Taking out existing CC interlocking paver blocks from footpath/ central verge,includingremovalofrubbishetc.,disposalofunserviceable materialtothedumpingground,forwhichpaymentshallbemade separately and stackingof serviceable materialwithin 50Metre lead as per direction of Engineer-in-Charge. 200 Layingoldcementcocreteinterlockingpaverblocksofanydesign/ shapelaidinrequiredline,level,curvature,colourandpatternover and including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer- in-charge. (Old CC paver blocks shall be supplied by the department free of cost). 201 Providing and laying 80mmthickC.C.paverblockofM-35gradewith approved colour design and pattern.factory made chamfered edge Cement Concrete paverblocksinfootpath,parks,lawns,drivewaysorlighttraffic parkingetc,ofrequiredstrength,thickness&size/shape,madeby tablevibratorymethodusingPUmould,laidinrequiredcolour& patternover50mmthickcompactedbedof sand,compactingand properembedding/layingofinterlockingpaverblocksintothesand beddinglayerthroughvibratorycompactionbyusingplatevibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. completeall as per direction of Engineer-in-Charge. 202 Providing andfixingWhiteVitreouschinaOrissapatternW.C.panofsize 580x440 mm with integral type foot rests waterclosetsquatting pan(Indian typeW.C. pan)with100mmsandcastIronPorStrap,10litrelowlevel whiteP.V.C.flushingcistern,includingflushpipe,withmanually controlleddevice(handlelever)conformingtoIS:7231,withall fittingsandfixturescomplete,includingcuttingandmakinggood the walls and floors wherever required: 203 Providing and fixing W.C. pan with ISI marked white solid plastic seat and lid white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard makeandmosquitoproofcouplingofapprovedmunicipaldesign complete,includingpaintingoffittingsandbrackets,cuttingand making good the walls and floors wherever required : 204 Providingandfixing Oneurinalbasinwith5litrewhiteP.V.C.automaticflushing cistern whitevitreouschinaflatbackorwallcorner typelippedfronturinalbasinof430x260x350mmand 340x410x265 mm sizes respectively with automatic flushing cistern withstandardflushpipeandC.P.brassspreaderswithbrass unions and G.I clamps complete, including painting of fittings and brackets,cuttingandmakinggoodthewallsandfloorswhereverrequired : 205 ProvidingandfixingWhiteVitreousChinaWashbasinsize550x400mm with a pair of 15 mm C.P. brass pillar taps washbasinwithC.I.brackets,15mmC.P. brasspillartaps,32mmC.P.brasswasteofstandardpattern, including painting of fittings and brackets, cutting and making good the walls wherever require: 206 Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brasssingleholebasinmixerofapprovedqualityandmake, including painting of fittings and brackets, cutting and making goodthe walls wherever required:- (a)White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer 207 Providingandfixingwhitevitreouschinapedestalforwashbasin completelyrecessedatthebackforthereceptionofpipesand fittings. 208 Providing and fixing 610x510 mm bowl depth 200 mm Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required (Kitchen sink without drain board) 209 Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 Metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge. 210 Providing and fixing 10 litre capacity - White P.V.C. low level flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete. 211 Providing and fixing 10 litre (full flush) capacity-white controlled flush, low level cistern made of vitreous china with all fittings complete. 212 Providing and fixing G.I. inlet connection for flush pipe connecting with W.C. pan. 213 Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. 214 Providing and fixing15 mm nominal dia CP Brass Single lever telephonic wall mixer of quality & make as approved by Engineer in charge. 215 Providingandfixing 32mm diaFlexible pipe P.V.C.wastepipeforsinkorwashbasin including P.V.C. waste fittings complete. 216 Providing and fixing 100 mm sand cast Iron grating for gully trap. 217 Providingandfixinginposition25mmdiametermosquitoproofcoupling of approved municipal design. 218 Providing and fixing 600x450 mm beveled edge mirror of superior glass(ofapprovedquality)completewith6mmthickhardboard ground fixed to wooden cleats with C.P. brass screws and washerscomplete. 219 Providing andfixing Circular shape 450 mm dia mirrorofsuperiorglass(ofapprovedquality)andofrequiredshapeandsizewithplasticmouldedframeof approved make and shade with 6 mm thick hard board backing : 220 Providing andfixing 600x120x5 mmglass shelfwith edges round off, supported on anodised aluminium angle frame with C.P. brass bracketsandguardrailcompletefixedwith40mmlongscrews, rawl plugs etc., complete. 221 Providing and fixing C.P. brass toilet paper holder : 222 Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. 223 Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms. 224 Providing and fixing PTMT 450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm, weighing not less than 170 gms complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 225 Providing and fixing PTMT 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 226 Providing and fixing PTMT shelf 440 mm long, 124 mm width and 36 mm height of approved quality and colour, weighing not less than 300 gms. 227 Providing and fixing PTMT 15 mm Urinal spreader size 95x69x100 mm with 1/2 BSP thread and shapes, weighing not less than 60 gms. 228 Providing and fixing 15 mm nominal dia Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. (Internal work - Exposed on wall) 229 Providing and fixing 20 mm nominal dia Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. (Internal work - Exposed on wall) 230 Providing and fixing 25 mm nominal dia Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. (Internal work - Exposed on wall) 231 Providing and fixing 15 mm nominal dia Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.(Concealed work) 232 Providing and fixing 20 mm nominal dia Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.(Concealed work) 233 Providing and fixing 25 mm nominal dia Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.(Concealed work) 234 Providing and fixing 15 mm nominal dia Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) 235 Providing and fixing 20 mm nominal dia Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) 236 Providing and fixing 25mm nominal dia Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) 237 Providing and fixing 32mm nominal dia Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) 238 Providing and fixing 40mm nominal dia Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) 239 Providing and fixing 50mm nominal dia Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) 240 Providing and fixing 15 mm dia nominal bore G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc.(Internal work - Exposed on wall) 241 Providing and fixing 20 mm dia nominal bore G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc.(Internal work - Exposed on wall) 242 Providing and fixing 25 mm dia nominal bore G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc.(Internal work - Exposed on wall) 243 Providing and fixing 15 mm dia nominal bore G.I. pipes complete with G.I. fittings including trenching and refilling etc.(External work) 244 Providing and fixing 20 mm dia nominal bore G.I. pipes complete with G.I. fittings including trenching and refilling etc.(External work) 245 Providing and fixing 25 mm dia nominal bore G.I. pipes complete with G.I. fittings including trenching and refilling etc.(External work) 246 Providing and fixing 32 mm dia nominal bore G.I. pipes complete with G.I. fittings including trenching and refilling etc.(External work) 247 Providing and fixing 40 mm dia nominal bore G.I. pipes complete with G.I. fittings including trenching and refilling etc.(External work) 248 Providing and fixing 50 mm dia nominal bore G.I. pipes complete with G.I. fittings including trenching and refilling etc.(External work) 249 Providing and fixing 25 mm nominal bore gun metal gate valve with C.I. wheel of approved quality (screwed end) : 250 Providing and fixing 20 mm nominal bore gun metal gate valve with C.I. wheel of approved quality (screwed end) : 251 Providing and fixing 32 mm nominal bore gun metal gate valve with C.I. wheel of approved quality (screwed end) : 252 Providing and fixing 15 mm nominal bore ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 253 Providing and fixing 20 mm nominal bore ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 254 Providing and fixing 15mm norminal bore 45 cm length uplasticised PVC connection pipe with brass unions : 255 Providing and fixing 20mm norminal bore 45 cm length uplasticised PVC connection pipe with brass unions : 256 Providing and fixing 100 mm diameter C.P. brass shower rose with 15 or 20 mm inlet : 257 Providing and fixing 150 mm diameter C.P. brass shower rose with 15 or 20 mm inlet : 258 Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 259 Providing and fixing 15 mm nominal bore C.P. brass bib cock of approved quality conforming to IS:8931 : 260 Providing and fixing 15 mm nominal bore C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms. 261 Providing and fixing 15 mm nominal bore C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 262 Providing and fixing 15mm nominal bore C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 263 Providing and fixing C.P. Brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of Engineer-in-charge. 264 Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof. 265 Providing and fixing Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fastenersto be paid for separately) :(For fixed portion) 266 Providing and fixing Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fastenersto be paid for separately) :(For fixed portion) 267 Providing and fixing glazing With float glass panes of 4.0 mm thickness (weight not less than 10kg/sqm) in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): 268 Providing and fixing glazing With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm)in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): 269 Providing and fixing glazing With float glass panes of 8 mm thickness (weight not less than 20 kg/sqm)in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): 270 Providing and fixing With stainless steel cover plate minimum 1.25 mm thicknessdouble action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge. 271 Providing and fixing With brass cover plate minimum 1.25 mm thicknessdouble action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge. 272 Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying :(a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours.(b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. (The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.) 273 Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying:(a) after surface preparation, first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm.(b) laying second layer of Fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm.(c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around.(d) fourth and final layer of brick tiling with cement mortar (which will be paid for separately. (For the purpose of measurement the entire treated surface will be measured.) 274 Providing & Applying polymer modified, flexible cementatious negative side waterproofing coating with elastic waterproofing polymers on interior wall plaster surface in three coats @14.35 kg /10 sqm. one coat of self priming of cementatious waterproofing polymer(dilution with water in the ratio of 1:1) and two coats of cementatious waterproofing polymer(dilution with water in the ratio of 3:1 ) after scrapping and properly cleaning the surface to remove pre-existing paint film & loose particles till plaster is visible, complete in all respect as per the direction of Engineer-in-Charge. 275 Providing and applying of swellable type water stop tape, 19mm x 25mm thick in linear meter (expansive nature) for construction joints treatment of RCC structure such as raft slab, retaining walls, water storage tank and at the junctions of raft slab with the retaining walls etc.. After cleaning the surface, one coat of required primer for swellable water stop tape shall be applied throughout the length of the joint @3.78 litre per 240 running meter. Over the primed surface swellable type water stop tape shall be placed. The work shall be carried out all complete as per specification and the direction of the Engineer-In-Charge. The product performance shall carry guarantee for 10 years against any leakage. 276 Providing and fixing With15mmthick fullyperforatedsquare/buttedgelightweightcalcium silicate panels/ tiles in position wall panelling at all heights with integral densified calcium silicatepanels/tilesofsize595x595mm,havingNRC(NoiseReductioncoefficient)of0.50 (minimum) as per IS 8225:1987, Light reflectance of 85% (minimum). Non combustible as per BS:476 (part-4), fire performance as per BS:476 (part 6 &7), humidity resistanceof 100%,thermalconductivity<0.043W/mK asperASTM518:1991, comprising of a frame made from especially fabricated galvanised mild steel sheet 0.50 mmthickpressedsection(galvanizing@120gramspersqmincludingbothsides) i.e.vertical studs of size 48 x 34 x 36 mm are placed at 600mm center to center in a floor andceilingchannel sectionofsize50x32mfixedtothefloorandsoffitat600mm centersusing12mmdia,50mmlongwedgetypeexpandedzincalloy dashfastnerwith 10mm bolt. This same channel is then to be fixed in horiziontal direction at 600mm center to center so as to form a grid of 600mm x 600mm. Glasswool of 50mm thickness is then to be inserted in the slots and finallycalcium silicate non combustible panels/tiles are to bescrew fixed withselftapping panheadnickel coatedmild steelscrewsofsize13x3.2mmon tothisgridleavingan evengroove of1 mm betweenthepanels. The joints betweenthepanelsaretobedulyjointedandfinishedusingrecommendedjointing calcium silicate based compound and fiber joint tape roll 50mm wide(90 Metre )roll and twocoatsofprimersuitableforpanellingaspermanufacturersspecificationasper direction of Engineer-in-Charge all complete. 277 Providing and fixing With 16 mm thick beveled tegular mineral fibre false ceiling tile (NRC 0.55 to 0.6 mineral fibre false ceiling tiles at all heights of size 595X595mm of approved texture, design and pattern. The tiles should have Humidity Resistance (RH) of 99%,LightReflectance≥85%,ThermalConductivityk=0.052-0.057w/mK,Fire Performance as per (BS 476 pt - 6 &7)in true horizontal level suspended on interlocking T- Grid of hot dipped all round galvanized iron section of 0.33 mmthick (galvanized @120 gsm)comprisingofmainTrunnersof15x32mmoflength3000mm,crossTofsize 15x32mm of length 1200 mm and secondary intermediate cross T of size 15x32 mm of length600mm toform gridmoduleofsize 600x600mm suspendedfrom ceiling using galvanizedmildsteelitem(galvanised@80gsm)50mmlong8mmouterdiameterM-6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and L- shapeleveladjusterofsize85x25x2mm,spacedat1200mmcentretocentrealong main‘T’.Thesystemshouldrestonperipherywalls/partitionswiththehelpofGI perimeter wall angle of size24x24X3000 mm made of 0.40 mm thicksheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wallS.S. screws. The exposed bottom portion of all T-sections used in false ceiling support system shall be pre-painted with polyester baked paint, for all heights. The work shall be carriedoutasperspecifications,drawingsandasperdirectionsoftheengineer-in- charge. 278 Providingandfixingharddrawnsteelwirefabricofsize75x25mmmeshorother suitable size wire mesh to be fixed & firmly anchored to the concrete surface by means of L shaped mild steel shear key welded with existing reinforcement including the cost of materials, labour, tool & plants as approved by Engineer-in-charge. 279 FillingofjointsbetweenRCCplinthbeam/floorslabandwallpanelofexternalwalls, toilet / bath room / wet areas walls on all floor and parapet wall over roof slab, stair case headroomatthetimeoferectionofGFRGpanelswithGroutRW/equivalentsealant compound after the erection of panelbeforethe infill of concrete in panel cavities and fine finish. This applies for all horizontal and vertical joints between GFRG wall and slab panels. 280 WaterproofingtreatmentofVerticaljoints(ofexternalsideandinternalside)between doorframe,window&ventilatorframes(onallfoursides)ofouterwalloverthe Zycosil/equivalent & Zycoprime/equivalent solution already applied (before the installation of door / window / ventilator frames in position) and fine finish with Grout RW/equivalent. 281 WaterproofingtreatmentofRCCsunshadewith Zycosil/equivalentwaterproofing Solution(1litreofZycosil/equivalent&20litresofwaterstirredfirst&2litresof Zycoprime/equivalent addedandstirred (total23litres))till itmeetsthesaturationlevel and testing as per RILEM or bywater drops test in which water drops do not absorb but drops remain or rolls. 282 In-filling / sealing of joint between RCC lintel cum sunshade and wall (on external side) in all floors by pushing in Grout RW/equivalentin paste form and coving 20 mm x 20 mm after applying a coat of Zycosil/equivalent & zycoprime/equivalent solution before cement plastering of top, bottom and sides of RCC sunshade. 283 Concreteworkwith40mmgaugebrickballastobtainedfrombreaking brick bats (brick bats supplied by the department free of cost) in proportion of 12:6:1 as in CSI no. 5.01 includingcost of all labour, materials, T&P etc required for proper completion of work. 284 Brickworkinfoundation&plinthwitholddismantled bricks(suppliedby departmentfreeofcost)andcoarsesand mortarin1:6includingsupply ofallothermaterials,labour,removingmortar&cleaningofold&usedbricks,T&P etc complete. 285 Supply and filling brick bat in soak pit including all labour,material and T&Petc complete. (for 01 soak pit) 286 Supplying & fixing 24 gauge annodized aluminium sheet of approved qualityincludingcutting,wastageandfixingthesameoverthewooden door shutters with nails with all material, labour and T&P 287 Providingandfixinginplaceafullheightstoragecabinet450mmdeep made with19 mm thick ISI marked plyborad, allinterior surfaces to finishedwithpastingof0.8mmthickmicaandallexteriorsurfacestobe finshed with pasting of 1 mm thick mica of texture and colour as approved byEngineerinChargeincludingalllabour,T&P,otheritemslike(butnot limitedto)fevicol,nailsscrews,higes,sliders,doorhandles,multipurpose lockofgodrejorequivalentrateetc.requiredforpropercompletionof works, to be measured interms of front area only. 288 ProvidingandfixingfullheightPartitionwith02NOS12mmthickISI marked ply board, all surfaces to finished withf 1 mm thick mica of texture andcolourasapprovedbyEngineerinChargeandfixedinpolishedteak woodincludingalllabour,T&P,otheritemslike (butnot limitedto) fevicol, nailsscrews,hinges,sliders,doorhandles,multipurposelockofgodrejor equivalent rate etc. required for proper completion of works, to be measured interms of front area only 289 Providingandfixing12mmthickframelesstoughenedglassdoorshutter ofapprovedbrandandmanufacture,includingprovidingandfixingtop& bottom pivot & double acting hydraulic floor spring type fixing arrangement ,Doorhandle,lockandstopperetcandmakingnecessaryholesetc.for fixingrequireddoorfittings,allcompleteasperdirectionofEngineer-in- charge 290 Supply and fixing 6mm thick polycarbonate multiwall sheet ,fixing in position with J or U bolts 10 mm. dia with G.I. Limpet & bitumen washers including supply of all materials, labour,wastage. and T&P etc. required for proper completion of the work. 291 Providing (12x15) mm section groove in plasterincluding all material, labour andT&P etc. required for proper completion of the work.CSI No.11.16 292 2.5 cm thick 1:1.5:3 plain cement concrete floor with cement, approved coarse sand & 2cm graded approved stone ballast laid in panels finished with 3mm floating coat of neat cement or cement and marble dust in ratio of 5:1 as specified and removing any overlapping mortar at the joints of the panels if any and giving them a uniform finish including supply of all materials, labour and T&P etc, required for proper completion of the work. without base CCCSI No.12.26 293 4.0 cm thick 1:1.5:3 plain cement concrete floor with cement, approved coarse sand & 2cm graded approved stone ballast laid in panels finished with 3mm floating coat of neat cement or cement and marble dust in ratio of 5:1 as specified and removing any overlapping mortar at the joints of the panels if any and giving them a uniform finish including supply of all materials, labour and T&P etc, required for proper completion of the work. without base CC CSI No. 12.28 294 Dismantling ofdry B.O.E. Floor and proper stacking of dismantled bricks as per direction of E/C. up to 60 m lead. 295 Dismantling and re-laying of dry B.O.E. floor including cost of all labour and T&P required forproper completion of work.(labour rates only) 296 Cleaning panes of glass with spirit of caustic soda including supply of all materials,labour and T&P etc.required for proper completion of the work. 297 Cleaning of septic tank including disposal of waste out side the UPPCL area as per direction of the Engineer-in-charge including cost of all labour,T&P etc.required for proper completion of the work. 298 Cleaning and opening of chocked W.C./ bath / kithchen pipe line including opening and refixing of chamber cover including washing etc. complete.(Analysis based on NBO - 11 25.020. 299 S/laying chicken mesh of (20 mm.)hexagonal heavy quality over roofs of joints of roof as per direction of the Engineer - in - charge. 300 Cleaning of existing pipe line of different dia. ranging from 4 to 2 dia. including digging trenches and refilling, opening of pipes, cleaning of pipes, cutting, threading, if required fixing and including making good the road, wall etc as directed by the engineer I/C. 301 Cleaning of existing water pipe line of different dia up to 2 dia including digging trenches and refilling,opening and cleaning of pipes,cutting,threading,if required fixing and including making good the road and wall etc. as directed by the Engineer in charge. 302 Cleaning of R.C.C. over head tank up to capacity of one lac. Liters and chlorinating with blEaching power mixed to water as per direction of Engineer - in - charge complete. 303 Supply and mixing bleaching powder in over head tank as required or as directed by Engineer - in - charge. 304 Attending to petty maintenance service like plumbingservice,welder service, mansion service and carpenter servicerequired as below. (Job attending by one no. Plumber/welder/mason /carpenter with oneno. helper per hour or part of an hour.) 305 Cleaning and sweeping of roof of residence as and when requiredincluding uprooting of rank vegetation and disposal of thegarbage upto 50 M. 306 Providing and fixing of 150 mm dia PVC pipeof 6 Kg/sqcmwith special such as Tee, bend, socket, elbow etc including supply of all labour,material,T & P etc complete required for proper completion of work. 307 Providing and laying 75 mm Dia. SWR, PVC ( Finolex or equivalent ) pipe including cost of excavation, C.C etc including its jointing and connection, all materials, labour and T&P etc. required for proper completion of the work. 308 Providing and laying 90 mm Dia. SWR, PVC ( Finolex or equivalent ) pipe including cost of excavation, C.C etc including its jointing and connection, all materials, labour and T&P etc. required for proper completion of the work. 309 Providing and laying 110 mm Dia. SWR, PVC ( Finolex or equivalent ) pipe including cost of excavation, C.C etc including its jointing and connection, all materials, labour and T&P etc. required for proper completion of the work. 310 Making arrangement for sweeping, cleaning of road, lanes in back of houses,collecting refuse of bushes & unwanted plants, vegetations etc. & disposal of all rubbish, materials industbins inside the colony area with engaging atleast one number of sweepers including all labour, T&P,etc.required for completion of work as directed by E/I. 311 Making arrangement for sweeping, cleaning of EE,ECD(D), Georgetown ,Prayagraj office rooms, cleaning of dustbin, toilets , dusting of almirahs,tables etc. using phenyle,dusting cloth etc. and disposal of waste outside office premise in municipal dustbinswith engaging sufficient number ofsweepersincluding all labour, T&P,etc.required for completion of work as directed by E/I.(NSI)(consumable items as phenyle,dusting cloth ,brooms etc shall be provided by the department free of cost.) 312 Cleaning of main drain or width more than 300mm including disposal of waste refuses studge out side the boards ara including washing and cleaning by clean water completely as per direction of the E/I. including cost of all labour, T&P etc. required for completion of the work. (CSINo.20.14) 313 Cleaning of main drain or width less than 300mm including disposal of waste refuses studge out side the boards ara including washing and cleaning by clean water completely as per direction of the E/I. including cost of all labour, T&P etc. required for completion of the work. (CSINo.20.15) NSI Sl. No.63 314 Operation of tube well daily by a suitable experienced operator continously or in different intervals as per program as per program fixed by Engineer-in-charge including opening and closing of valves,changing of fuse wire etc. As requrird for proper running of Tube well. (NSI) 315 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required..Group C 316 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 3 pin 5/6 amp socket outlet 317 Supplying and fixing of 20 mm of medium class PVC conduit along with accessories in surface/recess including junction box, cutting the wall and making good the same in case of recessed conduit as required. 318 Supplying and fixing of 25 mm of medium class PVC conduit along with accessories in surface/recess including junction box,cutting the wall and making good the same in case of recessed conduit as required. 319 Wiring for circuit/ submain wiring with 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 320 Wiring for circuit/ submain wiring with 2 X 4 sq. mm + 1 X 4 sq. mm earth wire of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 321 Wiring for circuit/ submain wiring with2 X 6 sq. mm + 1 X 6 sq. mm earth wire of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 322 Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required . 323 Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required. 324 Supplying and fixing 5 amps to 32 amps rating,Single pole, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 325 Supplying and fixing 63 amps, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 326 Supplying and fixing 40 amps, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 327 Supplying and fixing 4 way (4 + 12), Double door, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 328 Supplying and fixing of 4 way (4 + 12), Double door surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 329 Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. 330 Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required. 1 or 2 Module (75mmX75mm) 331 Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm) 332 Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required. 4 Module (125mmX75mm) 333 Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required. 6 Module (200mmX75mm) 334 Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required. 8 Module (125mmX125mm) 335 Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required. 12 Module (200mmX150mm) 336 Supplying and drawing following 3 x 2.5 sq. mm sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 337 Supplying and drawing following 3 x 4 sq. mm sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.(DSR E&M 2022 1.17.21) 338 Rewinding of burnt ceiling fan with approved copper wire including cost of all materials, labour and T&P etc. complete (Burnt wirewill not be taken back.) 339 Greasing of ceiling fan after cleaning the bearing and shaft withoil / petrol and its testing. 340 Supply and fixing of LED Tube Light batten fitting suitable for up to 1 X 22 watt LED tube light on surface complete in all respect.(CSI No. 28.41) 341 Supply of 9 watt LED Bulb make Philips, Syska, Bajaj etc or its equivalent as directed by E/I. 342 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min, 350 RPM (tolerance as per IS: 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.(DSR E&M 2022 19.1) 343 Supply and Fixing of 5 blade Exhaust fan ventile air dx 225 mm of Havellsor equivalent make including all material, T&P etc required for proper completion of work as approved by engineer in charge.(CSI No. 28.38) 344 Supply and Fixing of 3 blade wall fan ofHavells platina 400 mm or equivalent including all material, T&Petc required for proper completion of work as approved by engineer in charge.(CSI No. 28.37)
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Uttar Pradesh View Result →
21.
Public Administrative Department #10363312 Price Bid
Tender For Construction Of New Office Building Of Municipal Board Nawa - CIVIL WORKSClearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth upto 30 cm measured at a height of 1 m above ground level and removal of rubbish upto a distance of 50 m outside the periphery of the area cleared. 2 Earth work in excavation by mechanical means (Hydraulic Excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sum on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including taking out the excavated soil and depositing and refilling of jhiri with watering & ramming and disposal of surplus excavated soil as directed with in a lead of 50 meter.All kinds of soils 3 Add extra for foundation/trenches/drains for every additional lift of 1.5 Mtr. or part thereof inAll kinds of soil 4 Supplying and Filling in plinth with blown sand under floors including watering ramming consolidating and dressing complete including cost of sand. 5 Supplying chemical emulsionin sealed containers including delivery as specified. Chlorpyriphos/Lindane emulsifiable concentrate of 20% 6 Diluting and injection Chloropyrifos Emulsifiable concentrate 20% with 1% concentration for PRE-CONSTRUCTIONAL Anti termite treatment as per IS 6313 part III as amended from time to time and creating a continuous chemical barrier under and around the column pits, wall trenches, basement excavation, top surface of plinth filling, junction of wall and floor along the external perimeter of building expansion joints, over the top surface of consolidated earth of which aproch is to be laid surrounding of pipes and conduits etc. complete as per specification (Plinth floor area only shall be measured for payment and excluding the cost of chemical emulsion) . 7 Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - M10 grade Nominal Mix 1: 3: 6 (1 cement : 3 coarse sand : 6 graded stoneaggregate 20mm nominal size). (UNDER FLOOR) 8 Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size). (FLOOR UNDER FOOTING AND FOUNDATIONS 9 Providing and laying in position specified grade ofcement concrete forall RCC structural elements upto plinth level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcement. M25 grade Design Mix by usingmin 410 kg of cement per Cum . 10 Providing and laying in position specified grade ofcement concrete for RCC structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers (if required ) excluding the cost of centering, shuttering and reinforcementfor Walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. M25 grade Design Mix by usingmin 410 kg of cement per Cum . 11 Providing and laying in position specified grade ofcement concrete for RCC structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcementfor Beams, suspended floors, roofs, griders having slopes up to 15º, landings, balconies, shelves, chajjas, lintels, bands, plain windows sills, staircases and spiral staircases etc. M20 grade Nominal Mix / Design Mix 12 Providing and laying in position Ready mix concrete manufactured in fullyautomatic Batching Plant andtransported to site intransit mixer for having continous agitated mixer, manufactured as per approved mix design of specified grade of RCC work including pumping of R.M.C. from transit mixer to site of laying , exculding the cost of centering, shuttering and reinforcement with all lead and lift including cost of admixtures in recommended portion as per IS 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer in charge.All works upto floor V floor. Design Mix by usingM-25 grade concrete by using min 410 kg of cement per Cum 13 Centering and Shuttering with plywood or steel sheets including strutting, propping bracing both ways and removal of formwork for foundation , footings,strap beam, raft , bases of columns etc. 14 Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel propsand removal of formwork for upto floor five level for : Walls (any thickness) including attached pilasters,buttressesplinthandstring course. 15 Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel propsand removal of formwork for upto floor five level for :Suspended floors, roofs, landings, staircases, balconies, girders, cantilevers, bands, coping bed plates,anchorblocks,sills,chhajjas,lintel,beam, plinth beam etc. 16 Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel propsand removal of formwork for upto floor five level for :Columns, pillars, posts and struts etc. 17 Add extra for additional height in centring, shutteringwhere ever required with adequate bracing, propping etc. including cost of de-shuttering and decentring at alllevels, over a height of 3.5 m, for every additional height of 1 metre or part thereof (Plan are is to be measured) 18 Providing and fabricating reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor five level.(Original producers who manufacture billet directly from iron ores and roll the bilets to produce steel conforming to IS:1786) Thermo-mechanically Treated bars (Conforming of relevent IS code) 19 Providing and fixing stainless steel railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). Grade 304 20 Steel work in built up tubular trusses including cutting, hoisting ( height upto 10 m) fixing in position and applying a priming coat of approved steel primer, welded and bolted including special shaped washers etc. complete.Hot finished welded type tubes. 21 Random Rubble stone masonry for with hard stone in foundation and plinth in Cement Sand mortar above 30 CM thick wall in: Cement Mortar 1:6 ( 1-Cement : 6-Sand). 22 Brick work with F.P.S. bricks of class designation 75 in superstructure above plinth level upto floor V level in all shapes and sizes in : Cement mortar 1 : 6 (1 cement : 6 coarse sand) 23 Half Brick work with mechanised autoclaved flyash lime bricks conforming to IS: 12894 :2002 of class designation 75 in superstructure above plinth level upto floor V level in. Cement mortar 1 : 6 (1 cement : 6 coarse sand) 24 Add extra providingand placing in position 2 Nos. ,6mm Ø M.S. barat every thirdcourse of half brick masonry 25 Providing and fixing Stone jali 40mm thick Red/Pink sand stone throughoutin cement mortar 1:3 (1 cement : 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment, matching the stone shade, jali patterns to be cut square to jali slab without any chamfers etc: 26 Plaster on new surface on walls in cement sand mortar 1:4 including rackingofjointsetc. complete fine finish : 20mm thick . 27 6 mm thick cement plaster to ceiling of mix1:3 (1cement : 3-fine sand) 28 Providing and applying white cement based puttyover plastered surface to prepare the surface even and smooth completeNew Plastered Surface (three or more coats) 29 Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade including all scaffolding:Two or more coats on new work including prepartion of base with primer, putty, lippy etc complete in all respect 30 Finishing walls with textured exterior paint of required shade as per approved colour complete as per manufacturers specificationsincluding primer coat and protecting coat including scaffolding and safety provisionTrowel Finish av. thickness 1500 to 2000 microns. 31 Painting with synthetic enamel paint of approved brand and manufacture togive an even shade :Two or more coats on new work 32 Making of drip course (Tapka) in cement sand mortar 1:6 width upto 40 mmand 10 mm thick as per approved design 33 Making grooves as per design in plaster 10mm to 20mm wide. 34 P & F 1st quality Heavy Duty Vitrified Double Charged tiles on floor, skirting and steps etc.in different sizes (thickness minimum 10mm) with water absortion less than or equal 0.08% and conforming to IS 15622 of approved make in all colour and shade, laid with 20 mm thick CM 1: 4 including grounting the joints with white cement and matching pigment etc complete.Size 600X600mm 35 size600 mm X 1200mm 36 P & F 1st quality Heavy Duty Vitrified glazed MAT tiles on floor, skirting and steps etc.in different sizes (thickness minimum 10mm) with water absortion less than or equal 0.08% and conforming to IS 15622 of approved make in all colour and shade, laid with 20 mm thick CM 1: 4 including grounting the joints with white cement and matching pigment etc complete. size600 mm X 600 mm 37 Providing and fixing 1st quality standard white, grey, ivory, fume red brown, light green, light blue and other light shades glazed tiles confirming to IS : 13753 & IS :15622 of size 200mm x 300mm in walls, floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (excluding the cost of cement plaster on walls and pillar). 38 Extraforusingsize above 200x300mm in glazed tiles and for using 400mm x 400mm MAT finishedtiles in place of 300mm x 300mm size. 39 Kota stone slab flooring 25 mm thick over 20 mm (average) thickbase laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing completewith base of cement mortar 1 : 4 (1 cement : 4 coarse sand) For area of each slab from 2001 to 5000 Sq.Cm 40 Kota stone slabs 25 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete For area of each slab upto 2001Sqcm 41 Extra for pre finished nosing in treads of steps of Kota stone/ sand stone slab. 42 Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard jointed with neat cement slurry mixed with pigment to match the shade of tiles includingrubbing and cleaning etc. complete on 20 mm thick bed of cement mortar 1:4 (1 cement : 4 coarse sand) Medium shade using approximately 50% white cement and 50% ordinary cement. 43 Providing and fixing Granite stone slab mirror polished and machine edge cut in walls, pillars, steps, Shelves, Sills Counters, Floors etc. laid on 12mm (Av.) thick base of cement mortar 1:3 (1 cement : 3 coarse sand) jointing with white cement mortar 1:2 (1white cement : 2 marble dust) with pigment to match the shade of the marble slab including grinding, rubbing and polishing complete.South Red1501 Cm2 to 3600 Cm2 Tiles 44 Extra for providing edge moulding to 15-18mm thick marble/ Granite/Kota stone counters, Vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge.Granite/Kota Stone Work Full Edge moulding 45 Extra for fixing marble /granite stone over and above corresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive including cleaning etc. complete 46 Extra for providing opening of required size & shape for wash basins/ kitchen sink in kitchen platform, vanity counters and similar location in marble/Granite/stone work including necessary holes for pillar taps etc. including rubbing and polishing of cut edges etc. complete 47 Providing and fixing 1st quality standard Marble printed/ Granite Shade or Light/dark shad glazed tiles confirming to IS : 13753 & IS :15622 of size 300mm x 600mm in walls, floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (excluding the cost of cement plaster on walls and pillar). 48 Providing and fixing wall panelling using soft wood frame of size 50x25mm @600 mm c/c in both directions duly treated with anti-termite treatment making grooves painting of grooves specification and drawing using : ISI 9 mm teak ply one side BWR 49 Providing and fixing pressed steel door frames confirming to IS 4351 manufactured from commercial mild steel sheet of 1.25 mm thickness including hinges jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25mm, or base ties of 1.25mm pressed mild steel welded or rigidly fixed together by mechanical means, adjustable lugs with split end tail to each jamb including steel butt hinges 2.5mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applyinga coat of approved steel primer after pre-treatment of the surface including filling with CC 1:2:4(M15 grade) complete as directed by Engineer-in-charge : Profile E 50 Providing and fixing external grade board solid core single leaf flush door shutters ISI 2202-67 marked using Phenol formal dehyderesinin glue both sides with approved steel fittings complete as per annexure A: 35 mm thick . Commercial Veneer both side 51 Extra for providing external lipping with 2ndclass teak wood battens 6 mm minimum depth on all edges of shutters (over all area of door shutter to be measured) Over item no. 8.13. 52 Providing & Fixing mica of approved make for inner/outer side of shutters with fevicol & nails completeas per approved by engineer in charge. 0.8mm thick mica 53 Providing and fixing M.S. sheet 1mm thicksingle leaf door shutter in angle iron frame 35x35x5mm suitabilly diagonally braced with 25x3mm flat iron above and below lock rail of size 50x5mm beading extra including all fittings, as per direction of Engg. incharge but excluding cost of chowkhats: including two coats of anit-corrosive red oxide primer paint 54 Providing and fixing fully panelled /partly panelleddouble leaf shutters frame for windows and ventilators as per approved design and drawings with approved steel fittings as per Annexure ‘A’ and width of styles, bottom and top rails 75mm including intermediate rails 50mm wide, beading of 25mm x 15mm size on both faces : 35 mm thickGhana wood grade I 55 Providing and fixing bright finished Mortice lock of approved make Godrej or equivalent withpair ofCP handles for doors with necessary screws etc complete (Best make of approved quality) as per direction of Engineer-in-charge. 56 Providing and fixing of uPVC casement fixed windows or ventilators manufactured in ISO 9001:2000 & 14001:2004 certified company. Frame : Made from the Extruded uPVC Window Profile Section of size 60 x 60mm having outer wall thickness of 2.25mm (+/- 0.2mm) and 3 box multi-chamber construction, White in finish, duly reinforced with 1.2mm thick G/J/U/O TYPE GI section. All the four corners shall be mitered cut & thermal welded so as to form window frame. Frame shall be milled with drain and air equalizer hole in order to be water tight and for drainage of acCumulated water, if any, to outer side. Fix Mullion made of 76 x 60mm uPVC Profile Section with steel reinforcement shall be provided in windows as per the requirement. Frame shall have ‘O’ type EPDM gasket fitted in in-built groove of frame profile for proper air & sound insulation of the shutter. Glazing bead of size 34 x 20mm with ‘K’ & ‘O’ type inner and outer EPDM weather seal gaskets alongwith 5mm thick ISI make plain float glass.All welding joints of frame and shutter shall be cleaned and milled with the CNC mechanism to provide uniform grooved finish on all visible joints. Hardware : Installation at Site : Complete window is to be installed on site with 10 x 100mm fastners with white cap in existing pre-finished wall cut-out cemented to glass level plane at all height & width and silicon glue is applied to fill up the crevices between wall and window frame. Complete in all respect as per the drawing and specifications and direction of engineer-in-charge. (Insert 6mm tougend glass) 57 Providing and fixing of uPVC Sliding windows: Frame Made from the Extruded uPVC Window Profile Section of size 106w x 50h mm having outer wall thickness of 2.5mm (+/- 0.2mm) and 3 box multi-chamber construction, White in finish, duly reinforced with 1.2 mm thick GI section. Frame shall have three track configuration, two for sliding of window shutter and one for mosquito mesh shutter. Vertical member of frame which bears the sliding shutter load shall have aluminium rail/track for smooth sliding of shutter rollers. All the four corners shall be mitered cut & thermal welded so as to form window frame. Frame shall be milled with drain and air equalizer hole in order to be water tight and for drainage of accumulated water, if any, to outer side.Shutter : The shutter of sliding window shall be made of 39w x 69h mm Extruded 3 box multi- chamber uPVC Window Profile Section of white colour having outer wall thickness of 2.5mm (+/- 0.2mm) provided with reinforcement of 1.5mm thick GI section duly mitered cut & thermal welded at all corners and fitted with uPVC glazing bead of size 22 x 20 mm with inner and outer co-extruded EPDM/TPE-Eweather seal gaskets alongwith 6mm thick ISI make plain float glass. Mesh shuttershall be made of 39w x 69h mm Extruded 3 box multi-chamberUPVC Window profile section of white colour having outer wall thickness of 2.5mm (+/- 0.2mm) provided with reinforcement of 1.5 mm thick GI section duly mitered cut & thermal welded at all corners and fitted with nylon/polymer mesh and rollers/pully. (Insert 6mm tougend glass) 58 Providing and fixingaluminum workfor doors ,windows, ventilators and partition with extruded built up standard tubular / appropriate Z sections and other sections of approved make conforming to IS :733 and IS :1285,fixed with rawl plugs and screws or with fixing clips ,or with expansion hold fasteners including necessary filling up of gap. at junctions , at top ,bottom and sides with required PVC/neoprene felt etc. Aluminium section shall be smooth ,rust free, straight ,mitered and jointed mechanically wherever required including cleat angle Aluminium snap beading for glazing /paneling , C.P. brass/ stainless steel screws Al. Tower bolt & Al. handle & Al. Aldrop etc.,all complete as per architectural drawings and thedirections of Engineer- in – charge .(Glazing and paneling to be paid for separately). For fixed portionPowder coating aluminum( minimum thickness of powder coating 50 micron) 59 Providing and fixing glazing in aluminium door, window ,ventilator shutters and partitions etc. with PVS / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge.(Cost of aluminium snap beading shall be paid in basicitem.)With float glass panes of 8 mm thickness 60 Providing and fixing 12 mm thick prelaminated three layer medium density (exterior grade ) particle board Grade I, Type II conforming to IS : 12823 bonded formaldehyde synthetic resin ,of approved brand and manufacture in paneling fixed in aluminium doors ,windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and direction of engineer-in-charge.Pre-laminatedparticleboardwithdecorativelaminationononesideandbalancinglaminationonotherside. 61 Grading roof for water proofing treatment withwater proffing compoundCement mortar 1:3 (1 cement : 3 coarse sand) 62 Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10mm and down gauge) including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : 63 Making khurras 450 x 450mm with average minimum thickness 50mm cement concrete 1 : 2:4 over P.V.C. Sheet 1 Mtr. x 1 Mtr. x 40micron finished with 12mm cement plaster 1 : 3 and one coat of neat cement, rounding edges and making and finishing the out let complete. 64 Providing & laying broken glazed titles on roof ( broken glazed tilesnot less than 9 Kg/Sqm) on top of hot bitumen @ 1.7 Kg/Sqm. (1.40 Kg ofVG-40 (30/40 )grade and 0.30 Kg/Sqm. OfVG-10 (80/100) grade) and joints filled with cement mortar 1 :2 (1 cement:2 marble dust mixed with water proofing compund all complete as per direction of Engineer-in-charge. 65 Providing and fixing glass strips in joints of terrazo/ cement concrete floors. 40mm wide and 4mm thick 66 Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying :a) first layer of slurry of cement @ 0.488 kg/sqm mixed with water proffing cement compound @0.253 kg//sqm .This layer will be allowed to air cure for 4 hours. b) Second layer of slurryof cement @ 0.242 kg/sqm mixed with water proffing cement compound @ 0.126 kg/sqm This layer will be allowed to air cure for4 hours followed by water curing for 48 hours. The rates includes preparation of surface treatment & sealing of all joints ,corners,junction with polymer mixed slurry. 67 Providing&fixingprecastcementconcretecoping1:2:4mix50mmthickcompleteas per specification : 68 Providing & fixing UV stabilised fiberglass reinforced plastic sheet roofing upto any pitch including fixing with polymer coated ‘J’ or ‘L’ hooks, bolts & nuts 8mm dia. G.I plain/bitumen washers complete but excluding the cost of purlins, rafters, trusses etc. The sheets shall be manufactured out of 2400 TEX panel rovigs incorporating minimum 0.3% Ultra-voilet stabiliser in resin system under approximately 2400 psi and hot cured. They shall be of uniform pigmentation and thickness without air pockets and shall confoim to IS 10192 and IS 12866.The sheets shall be opaque or translucent, clear or pigmented, textured or smooth as specified. 5.0mm thick (Wt. 8.4 Kg./Mtr. Sq.) 69 Providing & fixing 12 mm thick tegular edge Glass Fibre Reinforced Gypsum False ceiling tiles of size 595 x 595 mm in true horizontal level suspended on inter locking metal grid of hot dipped galvanised steel sections ( galvanized @ 170 gsm/Sqm.) consisting of main “T” runner with suitably spaced joints to get required length and of size 24x38mm made from 0.30mm thick (minimum) sheet spaced at 1200mm center to center and cross “T” of size 24x25mm made of 0.30mm thick (minimum) sheet, 1200mm long spaced between main “T” at 600mm center to center to form a grid of 1200x600 mm and secondary cross “T” of length 600mm and size 24x25mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600mm panel to form grids of 600x600mm and wall angle of size 21x21x0.30 mm and laying false ceiling tiles of approved texture in the grid including, wherever, required, cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main “T” runners to be suspended from ceiling using GI slotted cleats fixed to ceiling with 6 mm dia and 50mm long dash fasteners, 4mm GI adjustable rods with galvanised level clips spaced at 1200mm center to center along main T, bottom exposed width of 24mm of all T-sections shall be pre-painted with polyester paint, all complete at all heights as per 70 Providing and fixing 12.5 mm thick tapered edge gypsum board conforming to IS 2095- Part I at all height false ceiling including providing and fixing of frame work made of special sections power pressed from M.S. sheet and galvanised in accordance with zinc coating of grade 350 as per IS : 277 and consisting of angle cleats of size 25mm wide x 1.6mm thick with flanges of 22mm and 37mm at 1200mm centre to centre one flange fixed to the ceiling with dash fastener 12.5mm diax40mm long with 6mm dia bolts to the angle hangers of 25x25x0.55mm of required length, and other end of angle hanger being fixed with nut and bolts to G.I. channels 45x15x0.9mm running at the rate of 1200mm centre to centre to which the ceiling section 0.5mm thick bottom wedge of 80mm with tapered flanges of 26mm each having clips of 10.5mm at 450mm centre to centre shall be fixed in a direction perpendicular to G.I. channel with connecting clips made out of 2.64mm diax230mm long G.I. wire at every junction including fixing the gypsum board with ceiling section and perimeter channels 0.5mm thick 27mm high having flanges of 20mm and 30mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450mm centre to centre with 25mm long drive-all screws @ 230mm interval including jointing and fixing to a flush finish of tapered and square edges of the board with recommended filler, jointing tapes, finisher and two coats of primer suitable for board as per manufactures specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed all complete as per drawing and specification and direction of the Engineer in Charge but excluding the cost of painting. 71 P & F European type white glazed vitreous china 1st quality W.C pan (IS : 2556 Mark) with P or S trap including cutting and making good the wall and floor 72 P & F water closet Seat Covers with brass hinges complete :Solid PVC (ISI marked) grade-I White for EWC. 73 P & F White Vitreous China Double Syphonic European W.C. (I.S:2556Mark) with mounted W.V.C. flushing cistern of (IS : 2556 Mark) of 10 litre capacity complete with all necessary internal fittings including cutting and making good the wall and floor. 74 P & F Indian type white glazed vitreous china 1st quality W.C. orissa pan (IS :2556 Mark) with 100 mm vitreous china P or S trap including cutting and making good the wall and floor: (Size 580x440 mm.) 75 P & F Low level Flushing Cistern of 10 litres capacity (IS : 2556 mark) of approved make with complete fittings C.I. brackets duly painted, brass ball cock with ball (IS: 1703 mark) complete including cutting and making good the wall: :PVC with PVCbend as per IS : 7231 . 76 P & F WVC Wash basin (Ist quality IS:2556 Mark) of approved make with C.I. brackets duly painted 1 No. 15 mm C.P. Pillar cock (IS:8934 Mark) & 32 mm C.P. brass waste coupling of approved make, P.V.C Waste pipe with PVC nut 32 mm complete including cutting & making good the wall : Size 630 mm x 500 mm dia for counter top 77 P & F Bevelled edge Mirror/mirror with teak wood lipping around of special glass of approved make as per direction of Engineer-in-charge complete with 6mm thick commercial ply base fixed to wooden screws & washers. Size 600 x 450mm x 4 mm thick 78 Stainless Steel Sheet size 125mm dia. Heavy Quality of approved make 79 P & F Liquid Soap Container with brackets complete of approved make: C.P. brass 80 P & F Jet spray for water closet with C.P. Copper Tube flange of approved make. 81 P & F G.I. pipes (Internal Work) with G.I. Fittings excluding union (IS:1239 Mark) & MS clamps including cutting and making good the walls and floors:15 mm dia nominal boreB Class 82 25 mm dia nominal boreB Class 83 P & F G.I. Pipes (External Work) with G.I. fittings excluding union (IS : 1239 Mark) including trenching & refilling earth etc.15 mm dia nominal boreA Class 84 25 mm dia nominal boreA Class 85 50 mm dia nominal boreA Class 86 Concealed pipe in wall including painting with anticorrosive bitumen paint 15 mm dia nominal boreB Class 87 P & F Bib Cock (IS : 8931 Mark), Superior quality of approved make: C.P. Brass bib cock,15mm nominal bore. 88 P & F Stop Cock(IS :8931 Mark),superior quality & ofapproved make: Brass 400 gm. 15mm nominal bore. 89 P & F Ball Cock (IS :1703 Mark) with Rod& P.V.C. Ball complete : Brass wt.Not less than 400 gm, 20mm. 90 P & F Inlet Connection (Angle Valves) Superior quality, of approved make, for Wash basin, Gyser etc.C.P. Inlet connection 15mm.Brass (IS : 8931 marked) 91 P & F Full-way Valve (IS:778 Mark) or wheel valve of approved make :Gun-metal 15mm nominal bore. 92 Gun-metal 25mm nominal bore. 93 Gun-metal 50mm nominal bore. 94 P & F Gun-metal Non-return Valve or Check Valve (IS :Make) of approved make, superior quality:50mm nominal bore. Horizontal 95 P & F PVC Storage Tank ISI Marked (IS : 12701) indicating theBIS license No),of approved make with cover, 25mm dia 1M long G.I. over-flow pipe & 25 Cm. long wash out pipe with plug & socket, including making connection etc., complete of approved desig1000 Lt. Capacity 96 500Lt Capacity 97 Hoisting Charges for each floor :For ITEMS 2.26.1 TO 2.26.4 98 For ITEMS 2.26.5 TO 2.26.8 99 P&F rigid PVC Pipe (IS:4985 mark) class II/ (4 Kg. /Cm2.) approved quality /makeincluding joining the pipe with solvent cement rubber ring and lubricant110mm dia 100 160mm dia 101 P&FrigidPVCpipefittings(IS:4985mark)ofapprovedquality/makeincludingjoining the pipe with solvent cement rubber ring and lubricantCoupler (socket)75mm dia 102 110mm dia 103 160 mm dia 104 Reducer 110 X 75 mm110mm dia 105 160 mm dia 106 Plain Tee75mm dia 107 110mm dia 108 160 mm dia 109 Door Y110mm dia 110 160 mm dia 111 Bend 45110mm dia 112 160 mm dia 113 Bend 87 .5110mm dia 114 160 mm dia 115 Door Bend (Top Side110mm dia 116 Vent Cowel110mm dia 117 P- Trap110mm dia 118 Gully trap110mm dia 119 Construction of manhole in all type of soil inner size 90 X 60 Cm. 300 mm thick masonry in CM 1:6, 10 Cm. thick cement concrete 1:5:10 in foundation, 20 mm thick inside plaster in CM 1:6, finished with floating neat cement, 50mm thick M-15 grade C.C. flooring, making channels, 80mm thick stone slab covering with 40mm thick M-15 grade C.C. flooring, Cement cover with frame of 450mm dia, earthwork etc. complete as per design including disposal of surplus earth within 50 mtr. lead.Depth up to 0.5 M 120 Construction of Man hole, in all types of soil, inner size 1.5 x 1.2 M, with 450mm thick masonry in CM 1:6, 10 Cm. thick cement concrete 1:5:10 in foundation, 20mm thick inside plaster in CM 1:6, finished with floating neat cement, 50 mm thick M-15 grade C.C. flooring making channels, 80 mm thick stone slab covering with 40 mm thick M-15 grade C.C.flooring, Ferro Cement cover with frame of 450mm dia, earthwork etc. complete including disposal of surplus earth within 50 mtr. lead as per design :Depth up to 1.5 M 121 Construction of chamber in all type of soil with 300 mm thick masonry in CM 1:6 m 10 cm thick C.C. 1:5:10 in foundation, 20mm thick insider plaster in Cm 1:6, finished with floating neat cement, 50mm thick M-15 grade C.C. flooring , earthwork etc. complete as per design including disposal of surplus earth within a lead of 50 mtr. Inside size 450 x 450mm depth upto0.5 M Cement cover with frame 122 Construction of septic Tank in all types of soil with 40 Cm .thick masonry in CM 1:6, 15 Cm thick C.C bed of 1:5:10, M-15 grade C.C flooring & over stone slab covering ,80 mm thick slab ,jointing of slab in CM 1:3. Ralthal, Kharanja,50 mm thick stone partition walls, 20 mm thick plaster in CM 1:6 finished with neat floating cement, 4 Nos C.I foot rests of approved design ,two No. 450 mm dia each Ferro cementcover with frame, earth work etc. complete as per approved drawing including disposal of surplus earth within a lead of 50 mtr:- Size 400 x140x150 cm.(for 50 users) 123 Providing and Fixing Unplasticized Poly Vinyl Chloride (UPVC) SWR Pipes Type B for sciland waste discharge system (IS:13592 : 1992 Marked) of approved quality /make75 mm dia 124 110 mm dia 125 Providing and Fixing Unplasticized Poly Vinyl Chloride (UPVC) SWR Pipes fittings type B for sciland waste discharge system (IS:13592 : 1992 Marked) of approved quality /makeCoupler75mm dia 126 110mm dia 127 Bend 87.5 Dg.75mm dia 128 110mm dia 129 Bend 45 Dg.75mm dia 130 110mm dia 131 Door Bend 87.5 Dg.75mm dia 132 110mm dia 133 Single Y75mm dia 134 110mm dia 135 Socket Plug75mm dia 136 110mm dia 137 Pipe Clip75mm dia 138 110mm dia 139 Nahani trap with jali 4110mm dia 140 Vent Cowel 110mm dia 141 P & F W.V.C. (IS: 2556 Mark) Squatting Urinal of standard make complete. Including cutting & making good the floor:Size 450x350mm 142 P & F lst quality WVC Urinal (IS:2556 mark) with 25mm dia G.I. waste pipe, dome waste couplings, concealed iron brackets or screws etc complete.Flat Back (small) size 456x355x265mm. 143 Construction of soakage well in all type of soil with 300 mm thick dry masonry, top and bottom 300 mm course in CM 1:6, 80mm thick stone slab, jointing of slab in CM 1 : 3, Ralthal, Kharanja, 40 mm thick M-15 grade C.C flooring , earthwork complete as per approved drawing including disposal of earth within a lead of 50 mtr.:Size 240 Cm. dia outside & 240 Cm. depth 144 Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth upto 30 cm measured at a height of 1 m above ground level and removal of rubbish upto a distance of 50 m outside the periphery of the area cleared. 145 Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30cm in depth. 1.5m in width as well as 10 Sqm on plan) including disposal ofexcavated earth, lead upto 50m andlift upto 1.5 m , disposed earth to be levelled and neatly dressed : All kinds of soil 146 Supplying and Filling in plinth with blown sand under floors including watering ramming consolidating and dressing complete including cost of sand. 147 Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level. :M10 grade Nominal Mix 1: 3: 6 (1 cement : 3 coarse sand : 6 graded stoneaggregate 40mm nominal size). 148 Providing laying, spreading and compacting specified graded crushed stone in sub-base course including premixing the material at OMC in wet mix plant, carriage of mixed material, laying in uniform layers with motor grader, F.E.loader on a prepared surface and compacting with vibratory compactorto achieve the desired density including all material, labour, mach-nery, lighting barricading and maintenance of diversion complete.[MoRTH specification Clause 401] includiong with all lead 149 Providing and laying at or near ground level factory made kerb stone of M-25 grade cement in position to the required line, level and curvature jointed with cement mortar 1:3 (1 cement : 3 coarse sand ) including making joints with without grooves (thickness of joints except at sharp curve shall not to more than 5mm) including making drainage opening wherever required complete including painting etc. as per direction of Engineer-incharge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineerin- charge). 150 M-40,80mm thick to be used in medium- traffic ( Medium traffic is defined as a daily traffic of 150-450 commercial vehicles exceeding 30 KN laden weight, or an equivalent of 0.5 to 2.0 MSA for a design life of 20 years.) like city streets, small and medium market roads, low volume roads, utility cuts on arterial roads, etc Category A Denated units to key into each other on four faces zigzagshape as per IRC SP 63:2004 151 Construction oftubewell up to 100m depth and above to accomodate housing and assembly pipe in all types of alluvium strata by rotay drilling method with code of practice for construction and testing of tubewells (IS:2800 (Part-II) : 1991 and IS:2800 (Part-II) :1979 both amended up to date) with supply of bail plug if necessary.The work will not include cost of housing pipe and strainer pipe assembly cost, gravel and development work. Work would be deemedcompleted only after obtaining sound free water during pumping.200 mm nominal bore 152 Diameter 900 mm+C159Construction of Recharge Shaft in filter pit including Earth work Excavation , lifting excavted earth with all lift and 50 m lead and centering & shuttering evenever required. 153 Supply & fixing Pre-cast RCC Rinngs at the mouth of recharge shaft of M20 mix with40 mm thicknessDiameter 900 mm 154 Supply & lowering air line of 25mm dia, G.I. pipe B class having perforation 3 to 5mm size all arrow of G.I. pipe in Zig-Zag fashion & making air vent at top including the cost of Tee-Nipples, Elbow, Socket etc. 155 Supply and lowering vent air pipe 63mm dia rigid PVC pipe(IS 4985) mark class II (4kg per cm2 ) with required all necessary fittings including perforation of 3 to 5 mm size all around the pipe at a distance of 180 to 220mm in zig zag fashion and making air vent at top complete as per direction of Engineer incharge. 156 Supply & lying River-gravels of following sizes in recharge shaft, filter pit after screening & washing from kachha shift without deduction of voids Size 9 to 12 mm 157 Size 3 to 5 mm 158 Supply & laying of clean, clear sharp river sand of size 1 to 2mm coarse, without deduction of voids. 159 Supply of strainer pipes made of ERW M.S. black pipe ISI mark of following sizes at the site of work including required size of slotting as per IS:8110-1985. 200 mm Nominal Bore. 160 Supply and Fixing of Big steel Almirah overall size of916mm (W )x486mm (D )x1980 mm(H) with weldedconstruction. It should have the shelf thickness of 0.7mm, Back thickness of 0.8mm, Door thickness of 0.8mm (high y eld strength) and all other components shall have a thickness of 0.9mm. The Almirah should have a Mazak handle and Three way locking mechanism with Shooting Bolts.It should have a height wise adjustable shelf mounting .Itshould also have a M10 Screw type Leveller with Hex plastic base. The finishing shall include Epoxy powder coated. Plenty of colour options and shelving options shall be available ISimarka brand (Godrej or equivalent) as per approved colour, shape,design,type by engineer in charge. 161 Supply and Fixing of small steelAlmirah overall size of 760mm (W )x455mm (D )x1325 mm(H)with welded construction. It should have the shelf thickness of 0.7 mm, Back thickness of 0.8mm, Door thickness of 0.8mm (high yield strength) and all other components shall have a thickness of 0.9mm. The Almirah should have a 2 Mazak handle and Three way locking mechanism with Shooting Bolts.It should have a height wise adjustable shelf mounting.It should also have a M10 Screw type Leveller with Hex plastic base. The finishing shall include Epoxy powder coated.Plenty of colour options and shelving options shall be available ISimarka brand (Godrej or equivalent) as per approved colour, shape, 162 Providing and supplying Canning Chair of size 455mm X 580mm X880mm. IIshould have wooden canning support at back and bottom supported by steel frame 3 2mm thick,powder coated round pipe with full armwooden handles onsides and other fittings as per direction of enaineer in charae. 163 Providing and supplying Canning Chair of size 455mm X 580mm X880mm. IIshould have wooden canning 4 support at back and bottom supported by steel frame2mm thick,powder coated round pipe without woodenhandles as per approved colour, shape,design,type by 164 Providing and supplying Officer high back Chair, The seat and back are made up of 1.2 cm thick hot pressed plywood, upholstered with fabric and moulded Polyurethane foam with PVC lipping all around.The back foam is designed with contoured lumbar support for extra comfort. BACK SIZE:65.0cm.(W) X 71.0cm.(H) SEAT SIZE:65.0cm. (W) X 65.0cm.(D) andreinforced with M.S. insert. The armrests are scratch and weather resistant. The armrests are fitted to the seat with seaUarmrest connecting strip assembly made of steel.The center pivot mechanism Is designed with the followingfeatures:360 revolving type.Tilt tension 5 adjustment. Upright locking.The pneumatic height adjustment has an adjustment stroke of 12.5 cm..The pedestal Is made of HR steel and fitted with 5 nos.twin wheel castors (castor wheeldia. 5.0cm.). The pedestal is covered with a P.P moulded cladding for modem and aesthetic looks.The pedestal is 65.0 cm. pitch-centre dla.(75.0 cm with castors). The twin wheelcastors are injection moulded In 30% Glass Filled black Nylon, as per approved colour, shape,design,type by engineer In charge. 165 Providing & Supplying table or size 1500mmx900mmx750mm, Top should be nnished with 18mm MDF Bos:d post formed Both side with 0.6mm laminate of approved make & design & with appropriate balancer on the bottom or the top. All verticals supportsincluding Modestypanel should be of 18mm prelaminated MDF Board with 2drawers & 16 Swing door per approved design.The drawers to beprovided with ai:proved handles and fixed on Telescope channels.AppropriateEdge Bendings to be provided where necessary with PVC beading 2mm thick to be provided. Footrest to be provided with 1Bmm MDF prelaminated board of the same color code.P&F PVC wire managers capslo be provided on the table top, as approved colour,shape, design,type by engineer In Charge 166 Providing & Supplying side table of size 900mmx450mmx750mm. Top should be finished with 18mm MDF Bos:d post formed with 0.6mmlaminate oras same as the Table,approved make & design & with appropriate balancer on the bottom or the topAllvert icals supportspanel should be of 1Bmm prelaminated MDF Board. Having 2Drawers & 1Swing7 door CPU unit. Keyboard tray, with mouse rest to beprovided.Appropriate Edge Bendings to be provided where necessary with PVC beading 2mm thick to be provided as per design.The drawers to be provided with approved handles and fixed on Telescope channels.P&F PVC wire managers caps to be provided on the table top, as per approved colour, shape,design, 167 Providing and $Upplylng table of size 1200mmX 750mmX750mm high as per design. The table top should be finished with 0.6mm thick laminated postrorming on 18mm thick MDF board.The 3 drawer unit (provided withlocking mechanlsm)and all other8 exposed vertical supports should be finished with steel members or approvedshade,colour and make.Appropriate moulding/edge bindingto be provided where necessary with PVC beading 2mm thick lo be provided as per approved colour, shape,design, 168 Providing & Supplying Computer table of size 900mmx450mmx750mm.Top should be finished with 18mm MDF Bos:d post formed with 0.6mmlaminate or as same as the Table,approved make & design & withappropriate balancer on the bottom or the topAllverticals supports panel should be of 1Smm 16.00 Each 12100.00 1g3500.oo prelaminated MDF Board. CPU uni Keyboard tray,with mouse restlo be provided.Appropriate EdgeBendlngs to be provided where necessary with PVC beading 2mm thck to be provided as per approved 169 Providing & Supplying depository/cashcabinet made up of CRCA steel with external size or 5g1 x 460 x 460 mm,2 nos of lockable drawers and single door cabinet fitted 3.00 Each 22848.00 68544.00with 6 leverlock system 1vith completein all respect. (approx weight 160 kg to 180 kg) as per approved 170 Book Case - 4 Door Book Case shall have the configuration or 914mm(W)x320mm(D)x1742mm(H). The unique design provides the right rigidity to the Top hinged doors ,which shall faci itate easy use.The Book Case shall be made fromprime quality steel. It shall have a Rigid Knock Down Conslructlon.The TopPannel, Back Pannel and Side Pannel are made from 0.7mm high yield CRCA andother components from O.Smm CRCA. Each door shall have a 6 Lever Cam Lock with Comrron Key. 3mm thick glass should beused in each door for clear inside vision whih shall besecured Ina metalframe through a rubber gasket.11 Scissor Mechanism should be providedin each door for 20.00 Each 17248.00 344960.00receding Inside the top or every compartment andItshall ensure parallel and smooth movement. Each door should be provided with plastic side end caps as handle which Is easy to grip.Each compartment shall have a storage shelf with good capacity. The 4 Door Book Case shall have 18mm PLB Top straight edge with PVC lipping.The Hn shlngshall Include Epoxy powder coated.Complete work as per the as per approved colour,shape,design,type by engineer in charge. 171 150 cm high fencing of precast R.C. posts of 15cmx15cm tapered to 10x10cm at top placed at every 3m apart 30cm in ground embedded in cement concrete 1:3:6 (30x30x45cm) corner and every tenth posts to be strutted with same R.C. posts provided with 6 horizontal lines and two diagonals of black barbed wire between the two posts fitted and fixed with G.I. staples including earth work in excavation etc. complete 172 FIRE FIGTHING WORKProviding, Fixing, Jointing, Testing & Commissioning of Heavy duty MS C class (Heavy) pipes conforming to IS 3589 / 1239 part-I for hydrant and sprinkler applicationsincluding cutting, screwing, welding etc. & forged steel fittings like elbows, tees, tapers, reducer, gaskets etc. fixing the pipe on the wall/ceiling with suitable clamps, hanger and nuts bolts including cutting hole and chase in brick or RCC walls/ slab and making good the same. complete with painting of one coats of Red Oxide and two or more coats of synthetic enamel paint of requiredshade complete as required. (Pipe to be tested @ 10Kgf/Sqcm for 2 Hrs.). All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 150 mm dia 173 100mm dia 174 80mm dia 175 50mm dia 176 40mm dia 177 32mm dia 178 25mm dia 179 Supplying and fixing first -Aid Fire hose reel Drum wall mounted swinging type with MS construction powder painted in post office Red, conforming to IS 884-1985 with upto date amendments, complete with the following as required.(A) Thermoplastic / Rubber Hose(B)20 mmdia UL, FM Bronze / SS nozzle with 5mm orifice (C)Drum and brackets for fixing the equipments on wall.(D) Connections from riser with 20/25 mm dia Brass/GM gate valves with screwed end and conforming to IS:778 Class-1through Forged steel Screwed Union & M.S. pipe. Etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . With 30 m x 20 mm High Pressure Braided Rubber Hose as per IS:5132 - 1969and Bursting pressure 42 Kg/sqcm 180 Supplying and fixing of SS 304 Single / Double headed oblique pattern hydrant landing valve (internal/external) with 75 / 100 mm dia flanged inlet & 63 mm dia instantaneous type female outlet coupling with cast iron wheel complete with ABS cap and chain and all accessories as per IS:5290-93 (Type-A) in cluding matching flange (14 mm thick),nuts, bolts, washers, gaskets,etc as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . Single Headed with 75 mm Dia. Flanged Inlet 181 Supplying and fixing of flexible hose made with 100% polyester, black EPDM internal rubber lining with External coat of synthetic elastomer (IS:636, type-A)63 mm dia, 15 mtr. Long RRL hose pipe with instanteneous type 63 mm dia SS-304male and female couplings(IS:903) duly bound and riveted to hose pipes with copper rivets and SS wire etc. as required.Appropriate Test Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. 182 Supplying & fixing SS-304 Short Branch Pipeconforming to IS: 903:93 fitted with 20mm (nominal internal diameter)bore nozzle, for projecting water in form of solid jet. The Branch shall have 63mm Male Instantaneous Inlet, suitable for use with 63 mm size Fire fighting hoses. H.P. tested to 21 kgf/cm² for 2.5 minutes. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 183 Supplying and fixing of 750 mm x 600 mm x 250 mm Outdoor application Fire Hose Cabinet made of 1.6 mm thick MS sheetDuly powder coated in red color externally and white internally with 6 mm thick glazeddoors with Expanded Metal 2 mm thick Jali including necessary locking arrangement suitable to accommodate 2 Nos 15 Mtr. Long RRL Hose and 1 No. branch pipe on Existing Wall / Angle Iron Frame as required. (Cost of MS structure for mounting Frame is to be Paid Extra) All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 184 Providing and fixing of Fire / Electrical Shaft Door made frompowder coated (50 Micron) aluminiumpartialy glazed with 6 mm thick glass and Partialy/ Fully Louvered with Outer frame of AluminiumSection of Size 100 mm x 45 mm x 1.5 mmand Shutters Top, Middle & sideSection of Size 82 mm x 45 mm x 1.5 mm, Bottom Section of Size 110 mm x 45 mm x 1.5 mmComplete with Hinges, Tower bolt, Handle, Aldrop, Locking Arrangement including dash fasteners of required dia and size, necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. as per drawings and the directions of Engineer-in-charge. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 185 Supplying, Installation, Testing & Commissioning ofElectrical Driven fire fighting duty Terrace pump as per TAC andIS 12469-1988., Factory assembledin Pump make OEMsuitable for automatic operation and consisting of following details given asA, B, C, D, E, F, G and H.(A) Horizontal End suction Centrifugal Back pull type pump complete for delivery of below mentioned discharge and Head(B) Material of construction : Pump Casing - Cast Iron, Impellor- Bronze, Shaft - SS 410, Packing - Mechanical Seal(C) Squirrel cage induction motor (IE-3 Class) suitable for 3 phase, 415 V, 50 HZ, Ac supply , Class -F Insulation, Synchronous speed not Exceeding 3000 RPM, T.E.F.C confirming to IP:55 , of required HP suitable for the above pump ,along with flexible (Love Joy type) coupling , coupling guard complete in all respect .(D)Common bed plate fabricated frommild steel channel for installation of pump and Motor including anti vibration pads.(E) The Hydrostatic tests (2 times of design operating head or 1.5 times the shut off head whichever is higher) and performance tests (to determine developed head, Pump BHP and efficiency v/s Flow) of pumps along with trip test shall be carried out at manufacturer’s works in Virtual / Physical presence of Department’s representatives.(F) Physical & Chemical Test reports of i) Pump casing (ii) Impeller (iii) Shaft (iv) Shaft sleeveand Dynamic Balance certificate is to be submitted by OEM(G) Suitable size Reinforced cementconcreat (M-30) foundation with foundation bolt, Nozing Angle of size 40mm x40mm x5 mm ( Cost of RCC Foundation to be paid Extra )(H) Weather proof hood fabricated from 5mm thick UV stablised FRP sheet supported by 50 mm x 50 mm x 5 mm Angle Iron fram above pumpset to protect it from weather All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR 450 LPM with 35 mtr head 186 Supplying and fixing Inlet Breeching Connection of CI body with Gun Metal male instantaneous inlet couplings with Inbuilt NRV, Drainage Connection with 50 mm Brass gate valvecomplete with PVC blank cap and chain as required for 150mm dia Outlet with 1 no. Matching Flange (Minimum 16 mm thick), nuts, bolts, washers, gaskets,etc as required of following Ways. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 4 Way 187 SITC of installation control valve of cast iron body and brass/bronze working parts comprising of water motor alarm, bronze seat clapper, and clapper arm, hydraulically driven mechanical gong bell to sound continous alarm when the wet riser/Sprinkler system activates, pressure gauges, emergency releases, strainer, pressure switch, cock valve complete with drain valve and bypass, test control box, ball valves, with 2 no. Matching Flanges (Minimum 16 mm thick), nuts, bolts, washers, gaskets,etc as required of following sizes.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 150mm dia 188 Supplying and Fixing of PN 16 Cast Iron Dual Plate Wafer Type Check Valve / Non return valve with SS / Bronze flap complete with 2 no. Matching Flanges (Minimum 16 mm thick), nuts, bolts, washers, gaskets,etc as required of following sizes. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 80 mm dia 189 100 mm dia 190 150 mm dia 191 200 mm dia 192 Supplying and Fixing of PN 1.6Butterfly Valve (Wafer Type) with S.G Iron Disc and confirming to IS:13095 complete with 2 no. Matching Flanges (Minimum 16 mm thick), nuts, bolts, washers, gaskets,etc as required of following sizes. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 150 mm dia 193 100 mm dia 194 80 mm dia 195 Supply & Fixing of Dry Powder Agent (as per IS 4308:2019), ABC typeFire Extinguisher (Stored Pressure type) conforming to IS:15683:2018 , Powder coated Internal & External Surface Deep drawn cylinder body of Mild Steel CR2 grade conforming to IS: 513, Squeeze grip Forged brass release valve with Inbuilt safety release device, Diaphragm Type, 0 to 28 bar range pressure gauge, 450 mm long EPDM discharge tube, QR code for Product Traceability including Fixing on wall with suitable Anchor Fasteners as required of following capacity. Test Certificates of all the Parameters along with Hydro test & Burst test (For Cylinder Body) Certificatefrom OEM / External NABL Accrediated Lab is to be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 6 kg 196 Supply & Fixing of CO2 type Fire Extinguisher conforming to IS:15683:2018, charged with CO2 gas (purity 99.7% conforming to IS 15222), Powder coated Internal & External Surface Manganese steel ISI marked as per IS 7285 cylinder body , Wheel type Forged brass release valve ISI Marked as per IS 3224 with Inbuilt safety release device ((Fusible plug and Rupture Disc Type), 1.0 Mtr. Metal wire braided hose having minimum bursting pressure of 140 Kgf/cm2, Horn with metallic thread connection, QR code for Product Traceability,including Fixing on wall with suitable Anchor Fasteners as required of following capacity. Test Certificates of all the Parameters along with Hydro test & Burst test (For Cylinder Body) Certificatefrom OEM / External NABL Accrediated Lab is to be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSRCapacity 4.5 Kg. 197 Supplying and Fixing ofGalvanized Mild Steel fire bucket Confirming to IS: 2546 : 1974 with one coat of primer and two coat of enamel paint of approved shade on Angle Iron ( 50 x 50 x 5 mm) Stand of Size 800 x 1240 x 400 mm with MS 22 SWG Galvanized Canopy, 4 Hooks for Bucketsincludingassociated civil works etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 198 SITC of UL 10th edition / EN54 / VDS certified Addessable Manual Call point (MCP) with LED/ FIRE Indication Etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 199 SITC of UL 10th edition / EN54 / VDS certified Addressable sounder with strobe light,Loop Powered / Direct powered from FACP with sound level 90 dB and programmablefrom the panel etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 200 SITC ofResponse Indicatorfor indicating the activation of the Remotely located Detector for Conventional type detectors as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 201 SITC of EN / LPCB/ UL listed / approved conventional automatic fire Alarm Rate of Rise cum fixed temperature thermister typeHeat Detectors , 12 / 24 volt D.C., visual alarm indicator (LEDs) Blink - green in stand by and Steady - red in alarm complete in all respectswith baseas required.including the cost of all accessories Etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 202 SITC of EN / LPCB/ UL listed / approved conventional automatic fire Alarm Optical/Photoelectric type smoke detectorsof photo-optic sensing chamber, 12 / 24 volt D.C., visual alarm indicator (LEDs) Blink - green in stand by and Steady - red in alarm complete in all respectswith baseas required.including the cost of all accessories Etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 203 Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 forlower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5,in existingsurface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure A attached with this BSR2 x 1.5 sq.mm 204 3x 1.5 sq.mm 205 Supplying and drawing PE Insulated & PVC Sheathed unarmoured telephone cable with 0.5 mm dia. Solid Annealed electrolytic grade bare Copper Conductor as per IS: 8130/84 &confirming to TEC specification GR / WIR/06-03 March 2002in existingsurface or recessed conduit/casing capping. including ferruling on each pair for Identification etc. as required. For additional technical parameters of product / work refer Annexure A attached with this BSR4 Pair 206 2 Pair 207 Supplying and fixingof CE certified and UL listed GI wire mesh cable tray made from spot welded steel wirehot dipped galvanised between 60 and 80 microns of zinc as per BS 729including horizontal and vertical bends, reducers, tees, cross members and other OEM made accessories like wall clamp, hold down clamps, Earthing terminal, brackets as required, and duly suspended from the ceiling with electro-zinc coated TF rods,etc. as required of following sizesAll as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR .500 mm x 100 mm x 6 mm 208 300 mm x 100 mm x 6 mm 209 SITC of UL 10th edition / EN54 / VDS certifiedActive Repeater Panel for Fire Alarm System with inbuilt networking port (both RS485 & Ethernet),Serial port for printer,two supervisory inputs,two position key switch and USB port for programming. The Repeater Panel shall allow users to acknowledge, reset,silence, program, view hisory events.etc (All functions similar to main panel)The user interface of the repeater panel shall be same as the Main Controller with menu driven user interface with smart search.including the cost of all accessories Etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 210 SITC of PA system Operator Console of following wattage to be installed withConventionalfire alarm systemcomplete with following capacity , channel mixing amplifier , 1 no cardioids goose neck microphone , 1 no professional grade cassette deck/ CD Player , 16 zone floor selector console ,equipment rack complete in all respects. PA system shall be coupled to the Fire Alarm System. Etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 1x 240 Watt 211 SITC 6 watt Speakermounted in M S sheet box with perforated front mesh for PA and Emergency System. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 212 Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)inrecessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit & itsISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thickHot Dipped Galvanized Modular Box with earth terminal, 10A Modular switch,Modular face plate with grid plate, 3 pin ceiling rose / Holder /3 way connector, screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSRMedium point (up to 6 mtr.) 213 Wiring of twin control light point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)in recessed ISI markedMMS ( IS:9537 P - III ) PVC conduit & its ISI marked (IS:3419-1988) accessories, round tiles, 2 Nos Hot Dipped Galvanized M.S Modularbox of 1.2 mm thickwith earth terminal,2 Nos10 A two way Modular switch, 3 pin ceiling rose / holder / 3 way connector ,Modular face plate with grid plate,screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSRLong point (up to 10 mtr.) 214 Long point(up to 10 mtr.) 215 Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal sizeFR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) inrecessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & its ISI marked (IS:3419-1988)accessories, Hot Dipped GalvanizedModular box of 1.2 mm thick with earth terminal, 10 A modularswitch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSRMedium point (up to 6 mtr.) 216 Long point(up to 10 mtr..) 217 Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 forlower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5,in existingsurface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure A attached with this BSR3x 1.5 sq.mm 218 3x 2.5 sq.mm 219 2 x 4.0 sq. mm. + 1 x 2.5 sq. mm. 220 2 x 6.0 sq. mm. + 1 x 4.0 sq. mm. 221 2 x 6.0 sq. mm. 222 4 x 10.0 sq.mm 223 4 x 16.0 sq.mm 224 P & F 1.2mm thickM.S. Recessed fan box, hexagonal/ round of size 130 mm dia, depth 75mm,12 mm dia rod fan hook with 100 mmlength extended on each side . All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure A attached with this BSR 225 Providing & Fixing ofBEEStar rated copper wounded double ball bearing capacitor start, aluminium body & Metallicblade ceilingfanConforming to all the performance requirements laid down in IS 374:2019 including all amendments, as applicable ; & Carry BIS licensing (i.e. ISI marking) with down rod up to 80 cm with secondary support safety cable ( steel rope) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .1200 mm Sweep BEE 1 Star rated (service value >=4.0 to < 4.5 ) 226 Providing & Fixing ofof BLDC Technologyventilating fans , single phase with PVC impeller, ABS body, Double Ball bearing, automatic back lower shutterincluding making connection, testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .250 mm sweep with Min. Air delivery 1150 cmh, 1300 RPM 227 Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load andsite requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting ofclass 3 as per IEC,minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted inexisting distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above ratingincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSRSingle pole MCB (With B/C curve tripping Characteristics) 6 A to 32 A rating 228 Double pole MCB(With B/C curve tripping Characteristics) 6 A to 32 A rating 229 Three pole MCB (With B/C curve tripping Characteristics) 6 A to 32 A rating 230 50/63 A rating 231 100 A rating 232 Four pole MCB (With B/C curve tripping Characteristics) 6 A to 32 A rating 233 50/63 A rating 234 Providing & Fixing of 240/415 V Residual current circuit breaker (RCCB) conforming to (IS:12640-1)/ IEC 61008 -1 , rated 4 KV impulse withstand voltage truly current operated and shall operate on CBCT mechanisum, provision for pad lock,min. operation 10,000 upto 63 A rating and5000 for 100 Aratingand minimum phase termination capacity of 35 sq.mm. rigid wire, IP 20 contact protection with existing distribution board / sheetincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSRTwo pole 30 mA sensitivity6A-32 A rating 235 40 A rating 236 Providing & Fixing of Recessed/surface mounting heavy duty horizontal type Double Door ( Metal / Glazed )Distribution board with Metal end box made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3, powder painted complete with reversible door (for double door DB only )100 amp. insulated copper bus bar/shorting link , copper neutral link, copper earth link , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, Ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSRGlazed door (single phase) IK-09 and IP-43 with Metal end box8 Way (8+2) 237 Metal door (Three phase) Per phase isolation, Horizontal IK-09 and IP-43 with Metal end box6Way(Incomer 8,Sub Incomer2+2+2) 238 Providing & Fixing of Recessed/surface mounting heavy duty Vertical TPN Distribution board with Metal end box withprovision of incomer suitable for MCB / RCCB and SP / TP MCB as outgoing ,made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3. powder painted with reversible door (for double door DB only ) complete with insulated 100 A rating copper bus bar, neutral bars with shrouds, earth bar , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure A attached with this BSR6 Way(8+18) 239 Supplying and fixing of power plug point with Modular accessories as per PWD specification for electrical Works, on hot dipped galvanized modular box of 1.2 mm thick with earthing terminal/connector on surface or in recessed with suitable size of modular face place with grid plate and cover plate including cost ofISI marked modular 16 amp. Switch (IS :3854) and 6/16 amp. socket outlet (IS:1293) making connection , testing , etc. as required. For specification ofWiring accessories refer ChapterE - 07related item & For additional technical parameters of product / work refer Annexure A attached with this BSR 240 Providing & Fixing of modular type switch/ bell push duly ISI marked (IS :3854) with CM/L no. printed and made out of unbreakable and fire retardant vergin UV Stabilized Polycarbonatewith brass terminals and captive screws & silver alloy contact tipwith IP-20 rating ,minimum width ofswitch toggle( PUSH PART ) should not less then 20mm,includingall as per pre approved by Engineer in charge,making connections, testing etc. as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 25 Amp.2 Moduleswitch With LedIndicator 241 Providing & Fixing of modular type lockable feature socket dulymade out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating , includingall as per pre approved by Engineer in charge,making connections, testing etc. as required. For additional technical parameters of product / work refer Annexure A attached with this BSR25 Amp. 2 Module Socket 242 Providing & Fixing of following modular accessories as per PWD specification for electrical Works,made out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating , includingall as per pre approved by Engineer in charge,making connections, testing etc. as required.For additional technical parameters of product / work refer Annexure A attached with this BSRRJ-11 telephone jack Double line 243 RJ-45, Cat 6 computer jack with shutter 244 Providing & Fixing offollowing size mounting grid plates with cover plates made from fire retardent UV established high performance engineering plastic suitable for all universal metal boxes for front installation & removal direct fit type complete in all respect.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .1 Module 245 4 Module 246 Providing & Fixing of modular type 120 W Step Fan regulator duly ISI marked (IS 11037:1984 ) with CM/L no. printedmade out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating ,includingall as per pre approved by Engineer in charge,making connections, testing etc. as required.For additional technical parameters of product / work refer Annexure A attached with this BSR5 step fan regulator 2 Module 360 dgree rotating 247 Plate Earthingas per IS:3043 with Hot dipped G.I. Earth plate of size 600mm x 600mm x 6.0mm by embodying3 to 4 mtr. below the ground level with 20mm dia. G.I. B class watering Pipe ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height250 to 300 mm. and embodying the pipecomplete with alternate layers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or lessas required & must record by engineer in charge during site visit and ensure to enter in measurment book.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 248 Supply & Laying following size earth stripin horizontal or vertical run in surface by means of Earth strip DMC Insulatorincluding riveting/ soldering/ welding, Jointing shall be done by overlapping and with 2 set of Brass (for Cu strip) / GI (for GI Strip) nut bolt & spring washer spaced at 50cm making connection etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 25mm x 6mm G.I. ( Hot Dipped) Strip 249 Supply & Laying following size B class , Medium class G.I. Pipe confirming to IS : 1239 P - 1 ( 2004 ) with accessories like bend, socket etc.for laying earth conductor/ strip / cable in ground/ surface/ recess as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 40 mm dia. 250 Providing & Fixing of IP20 SMD Mid Power LED batten type integrated light fixture made from Powder coated Extruded aluminiumhousing with in built driver, System lumen efficacy ≥ 110 lm/Watt output, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, CRI >80 , life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , Maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .1170mm(+/-10%) LED batten with min. lumen output 2200 lm 251 570mm (+/-10%) batten with min. lumen output 1000 lm 252 Providing & Fixing of IP20, 2x2 LED Surface/ Recessedmounting Mid power SMD type LED Light fixture not less than 50mm housing depth made from CRCA sheet steel housing, high purity / transmisivity UV stabilized Non -yellowish diffuser for uniform light distribution. High efficiency with 4 KV internal/external surge protection BIS certified isolated driver having efficiency > 85% , with Short & Open circuit protection(Integral with light fixture). System lumen efficacy of ≥ 120 lm/Watt ,THD < 10 % , p.f.≥0.95,CRI >80 ,life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted.All as per pre approved by Engineer in charge. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .Minimum lumen output 3600 lm 253 Providing & Fixing of IP-20 LED Recessed / Surface Mounted, Round / SqaureSMD Mid Power LED Downlight with power coated die-cast aluminum housingwith UV Stabilized non yellowish Diffuser withBIS complience 2.5 KV surge protected Isolated driver, with Short & Open circuit protection, having efficiency > 85% . System Lumen efficacy of ≥ 110 lm / watt, THD < 10 % , Pf.≥0.95, CRI >80,life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing.OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .Minimumlumen output 650 lm 254 Minimum lumen output 1950 lm 255 Supply, Drawing and Testing of 4 pair, 23 AWG Solid Bare Copper wire insulated with PVC, UTP (Unshielded Twisted Pair), Category 6, Class E, 100 Ohm Impedance, Indoor Cable as per latest ammendments of ANSI/TIA/EIA-568 , The copper conductors should be balanced twisted in pairs, seperated by a cross-member fluted pair divider & protected byPVC Jacket. Certified performance in a 4-connector configuration upto 100 Mtrs channel requirements & transmission frequencies up to 250 Mhz. in existing MS/PVC Conduits/casing capping including making connections to Information outlets and Patch Panels with jack &ferruling at both ends for identification with necessary tools for punching, stripping, crimping and testing etc as required complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 256 Supplying and drawing PE Insulated & PVC Sheathed unarmoured telephone cable with 0.5 mm dia. Solid Annealed electrolytic grade bare Copper Conductor as per IS: 8130/84 &confirming to TEC specification GR / WIR/06-03 March 2002in existingsurface or recessed conduit/casing capping. including ferruling on each pair for Identification etc. as required. For additional technical parameters of product / work refer Annexure A attached with this BSR2 pair 257 Supply and Laying of PE Insulated, PVC Inner Sheathed, armoured & PVC Sheathed Telephone Cable. with 0.5 mm thick Solid Annealed Bare Copper Conductor as per IS: 8130/84 telephone cable confirming to TEC specificationsGR/WIR 06/03, Mar.-2002 in existing pipe / open trench / Cable tray / on surface including making necessary connection, testing etc. as required of size. For additional technical parameters of product / work refer Annexure A attached with this BSR50 pair 258 S&F following sizes (dia.) of ISI marked virgin material MMS ( IS:9537 P - III ) PVC conduit along withISI marked (IS:3419-1988) accessories as requiredinrecessincludingcutting the wall, covering conduit and making good the same as required. For additional technical parameters of product / work refer Annexure A attached with this BSR25 mm 259 Supplying and fixing of ISO Certified company made Krone module with base frameas per PWD specification for electrical Works, in the recess / surface made out of 16 SWG sheet steel box, front openable, having locking arrangements duly powder painted., including dressing, ferrulingandpunchingof telephone cable with krone tool etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .50 Pairs 260 CCTV SURVEILLANCE WORKSupply, Installation, Testing and Comissioning of Rack mounted 19 1U, Cat6 24 Port loaded, 1.5-1.6 MM CRS chasis, powder coated, sheet steel, made of plastic (ABS), Modular Patch Panelswith Rear Cable management system and mounting hardware to mount the patch panel. Should have port identification numbers printed/engraved on front of the panel. Etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . Modular Patch Panel Loaded with Cat -6A I/O 261 Supply, Drawing and Testing of 4 pair, 23 AWG Solid Bare Copper wire insulated with PVC, UTP (Unshielded Twisted Pair), Category 6, Class E, 100 Ohm Impedance, Indoor Cable as per latest ammendments of ANSI/TIA/EIA-568 , The copper conductors should be balanced twisted in pairs, seperated by a cross-member fluted pair divider & protected byPVC Jacket. Certified performance in a 4-connector configuration upto 100 Mtrs channel requirements & transmission frequencies up to 250 Mhz. in existing MS/PVC Conduits/casing capping including making connections to Information outlets and Patch Panels with jack &ferruling at both ends for identification with necessary tools for punching, stripping, crimping and testing etc as required complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 262 Supply and Installation of unsheilded/360 degree sheilded Information outlets made of high impact plastic body with ABS, FR Grade halogen free material with provision for protection against dust in jack, suitable for Cat 6/6A application complying to latest ammendments, According. to Cat. 6/6A channel, It should support channel as well as components requirements of Cat.6/6A standards at frequencies of up to 250 to 500 Mhz. Cat 6/6A unshielded/shielded Jack should be suitable to terminate 4 pair, 23/24 AWG solid/stranded wire diameters, using 100 Ohm unshielded/shielded balance twisted pair cable, the jack should have tooless/impact termination on reliable copper tin plated Insulation displacement contact, with easy lock mechanism, It supports IEC 60603-7-4 and complied with ANSI/TIA/EIA 568 C.2 standard. jack should be RJ11,RJ12 & RJ45 compatible. Should support Ethernet 1.2 Gb/s ATM,Digital video and broadband/baseband analog video, Voice over internet protocal (VOIP) Specifications in existing modular/MS Boxes along with necessory connections as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . Cat 6A, Sheilded Information Outlet 263 Supply & fixing of square Faceplate for Flush / Surface Mount Information Outlets Single/Dual or Quad Aperture ,material should bePC+ABS body, Suitable for RJ45 unshielded/shielded connection modules. Should match with I. O. OEM. Dimensions should be 86mm X 86mm as required complete in all respect.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . Single Aperture 264 Supply, Installation, Testing and Comissioning of Rack mounted 19 1U, Cat6 24 Port loaded, 1.5-1.6 MM CRS chasis, powder coated, sheet steel, made of plastic (ABS), Modular Patch Panelswith Rear Cable management system and mounting hardware to mount the patch panel. Should have port identification numbers printed/engraved on front of the panel. Etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . Modular Patch Panel Loaded with Cat -6A I/O 265 Supply & Installation of IP-20 & IK-08 , UL ListedWall mounted Double Section Communication enclosure (Rack) made from powder coated (60 to 80 Micron) CRCA sheet, front sturdy sheet steel frame folded from one piece and welded with minimum 5mm toughened glass door,Vertical Mounting Rail 1.6 MM with UMarking , with All round protective channel on the door aperture, lock integrated on front door, top and bottom cover with cable entry provision with gland plates, integrated side walls, 2 pair of 19 angles with wall mounting provision on wall. Accessories like: 1 No of 19 1U Horizontal Cable manager, 1 No of 90 cfm 230V AC Fan with 1 mts long cable, mounting hardware , 1 No of 19 1U, mountable socket strips with 5 nos of 5A universal sockets with 2 mts long power chord for supplying power to switches, fans etc along with earth continuity kit, indicator, moulded power supply cable. fixing on wall with Suitable Anchor fastneretc as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 9 U Rackwith Width 600 mm & Depth 400 mm + 100 mm 266 Supply , Installation, Testing and Comissioning of Managed Layer-2 Intelligent PoE Giga Ethernet Switch providing 24 x 10/100/1000 MBPSPoE Giga Ethernet ports and with min 4 SFP Giga Ports (provision for Fiber Giga connectivity) with provision of minimum Stacking of 06 Switches with minimum 370 Watt PoE Power Budget with related LAN Base Software including making connections etc as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 267 SITC of 2 MP IR Fixed Dome Network Camera -1/2.7″ Progressive Scan CMOS, 1920 × 1080 at 25fps, 2.8 mm Fixed lens, 0.002Lux at F1.4, 0 Lux with IR on, ICR, ONVIF (PROFILE S, PROFILE G, PROFILE T), support H.265, H.264, MJPEG, 120db WDR, 3D Digital Noise Reduction, Three individually configurable stream, 12 VDC & PoE, IR range: 40m, Support on-board storage up to 256 GB (SD card not included), IP67, Edge Analytics- Line crossing detection, Intrusion detection, Motion detection, Video tampering, UL, CE, FCC certified. 268 Supply Installation testing and commissioning of 32 Ch Network Video Recorder- Connect Up to 64 IP Cameras, Up to 12 Megapixels Resolution, HDMI1/VGA1 and HDMI2/VGA2 outputs provided, atleast one HDMI output with 4K (3840 × 2160), atleast one VGA output with 2K (2560 × 1440) resolution, Support H.265/MJPEG, Supports N+1 hot spare system, Supports RAID0, RAID1, RAID5, RAID6 and RAID10, Supports HDD hot swap, Incoming Bandwidth 320 Mbps, 8 SATA Hard Disks, 1 × eSATA interface, ANR Technology, 8 SATA interfaces for 8 HDDs and capacity of each HDD upto 10 TB, Front panel: 2 × USB 2.0; Rear panel: 1 × USB 3.0, Alarm I/O 16/4, RS-232, RS-485, 2 RJ-45 10 /100/1000 Mbps self-adaptive Ethernet interface,Multiple network monitoring: Web viewer, CE, FCC, UL certified. with 30 days backup capacity asrequired. 269 SITC of professional PC alongwith printer and other accessories as required having minimum i7 processor, 8 GB graphic card 1 Tb SSD as per requirement. 270 SITC of 42 inch full HD professional LED display for CCTV monitoring. 271 External Electrical WorkS I T C of star ratedAluminium wound distribution Transformerof following rating 11/0.433KV Delta-Star Connected, Vector Group Dyn 11,ONAN Cooled & as per BEE star - 1 & BIS approved as per IS 2026- 1977 & lossesas defined as per 2014 (Fourth Revision) Level-1 . including standardaccessories like conservator, silica gel breather, radiator, fins, HT cable box & LT cable boxes, temperature rise in winding/oil 35-40 degree C upto 200 KVA & 40-45 degree C for above 200 KVA, ISI marked drain valve, Dial type Temperature gauge, first filling of transformer oil as per IS :335-1953, Epoxy based paint,including carrying of pre-commission Testing & Charging of Transformer complete in all respect .The Transformer shall be subjected to routine factory tests (as per IS:2026 and IS:1180) including testing from CTLof discombefore charging of transformer & complete installaion must be certified from Electrical Inspectorate office as per Indian Electricity rule, (CTL testing charges and Electrical Inspection charges shall be reimbursed by the department to the contractor). All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 100 KVA 272 SITC of PLC Based Auto main failure (AMF) Panel fabricated from CRCA sheet steel 2 mmThick , Powder coated finish , Engine Start & Stopcommands, control Relays , Ammeter & Voltmeterwith selector switches, Control & 2 nos 4 pole Power Contactors with 2 no. of required size 4 pole MCCB, Timers, Electronic Hooter ,Visual & Alarm indication for faults, UPS, operator interface panel complete in all respect suitable for following capacity DG sets: Appropriate Test Certificate/ report of product/accessories from OEM/Panel Manufecturer shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .20 to 40 KVA 273 Supply & fabrication steel structure with MS channel / angle / joist / ISMB / sheet etc. including welding, rivetting, cutting, nut & bolt , one coat of primer & two coat of enamel paint etc. as requiredcomplete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 274 Providing & Laying XLPE insulated three core ArmouredAluminiumcable for working voltage 11 K.V.(E) confirming IS :7098 P - 2withH4- Grade electrolyticaluminium conductor confirming to IS: 8130 class-2 of purity >99.6 %, Insulation Screening: Extruded Semiconducting Compound followed by helically wrapped Copper Tape, round / flat strip armouring of cables , Inner / outer sheath PVC type ST-2 confirming to IS:5831in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray includingtesting etc. as required of following size. OEM must have its own in house NABL accrediated Laboratory for testing procedure as per IS:10810 All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR .3 core 150.0 Sq.mm 275 MAIN LT PANELSITC of IP-42 and general construction confirming to IS:8623 : 1993, wall/ free standing floor mounted dust and vermin proof compartmentalisedcubical panel as specifications andOther parameters requiredas per point (a) ,(b), (c),(d), (e), (f), (g), (h) as below:-(a)Thickness of CRCA sheet shallbe 2.0 mm,cable alley compartments having concealed hinged type doors with key type lock with / withoutdetachable extension type structure. Removable 3 mm. thick sheet steel gland plates with appropriate size of knockouts for cables shall be provided(b)complete panel shall undergo a process of degreasing, Water rinsing, Activation, derusting,pickling in acid bath, phosphatising & shall be subjected to nine tank process and then Powder coated with approved shade of minimum 70 microns on both side of panel.The panel having PE foam/ Neoprene rubber gasket of not less than 3mm thickness ,required hardware , concealed hinged door with key type locking arrangement for equipment/switchgear earthed with 2.5 sq.mm braided copper wire.[c)Interconnection between bus bar and switchgears /cable shall be rigidly supported and made out by flexible copper wires (up to 63 amp ) and by solid bus bar(>63 amp ) . control wiring will be carried out with 1.5 Sq.mm, Earth wire with 2.5 Sq.mm and CT with 2.5 sq.mm flexible copper wire only.All joints / interconnections of copper bus bar shall be dully tinned . Clearance between main bus bar and risers / metal parts shall be at least 10 mm additional to width of bus bar Bus bar is insulated by Heat Shrinkable sleeves . Earth and Neutral bus bar shall be half of the size of phase bus bar. ( Cost of Bus bar/ Flexible wire for Interconnection between Main busbar and Switchgearis to be Paid Extra )(d)Wiring between components within switchgear and Incoming / outgoing cableshall be done through the terminal block only. Direct connection shall not be permitted. Each terminal block shall be one piece moulded, barrier type, 650 volt grade, complete with washers, heads, studs with two nuts and identification strips and shall have adequate continuous current rating. For tap-offs, adjacent terminals with shorting strips shall be used. 10% Spare terminal blocks shall be provided. Wire identification on marking strip shall correspond to the designation of the wiring diagrams. All wire terminals on the equipment shall also be marked with designation corresponding to those of the wiring diagram. (e)All wiring shall be enclosed in plastic channels and neatly bunched and closed in metering chamber, Wiring between terminals of various devices shall be ‘point to point’ (no wire splitting or tee connections) with wires neatly trucked along the back of the panels, adequately supported to prevent sagging.(f)Floor mounted panel shall be mounted on Base frame of ISMCchannel size 100 x 50 x 5 mm( to be paid Extra )(g) Tests: The insulation resistance (with 1000 V Megger) and High voltage Power frequency test (by applying a voltage of 2.5KV for one minute) shall be measured between phases, between phase and neutral and between phase and earth. both before and after high voltage power frequency test. The insulation resistance shall not be less than three megaohm. CT Secondary current injection test shall also be carried out.(h) only outer surface area on all sides shall be measured & panel to be fabricated only from CPRI approved fabricator only (CPRI Test certificates to be submitted)All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 276 SITC of3 /4pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant materialhaving following current rating, short circuitbreaking capacityat 440/415 V, 50 Hz; O/L & S/C settings , conforming to IS/IEC 60947 P -2 :2003 with frontface and centralised adjustable, trip free mechanisum, true contact position indicator,line load interchangeability,designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree,pollution degree 3, having positive isolation capability, push(test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% Icu. U imp =8 KV, rated insulation voltage690 V.provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connectionsetc. as required.OEM shall have submitNABL / CPRI / ERDA accrediated lab type test certificate before execution All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR4 pole MCCB With Thermal Magnetic release160 Amp , 25 kA, adjustable O/L & adjustable S/C setting, 277 up to 100 Amp , 10 kA, fixed O/L & fixed S/C setting 278 Supply and fixing of following accessories for Moulded case circuit breaker (MCCB)compatible to main MCCB OEM as per PWD specification for electrical Works, conforming to IS/IEC 60947 P - 2 :2003 including making connection etc complete in all respect. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test certificate before execution.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR .Shunt Trip Release 279 Under Voltage Release 280 Extended Rotary Handle 281 Auxiliary contact 282 Spreaders for 250A, 4 Pole MCCB 283 Spreaders upto 125A, 3 Pole MCCB 284 Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load andsite requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting ofclass 3 as per IEC,minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted inexisting distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above ratingincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSRSingle pole MCB (With B/C curve tripping Characteristics) 0.5 A to 5 A rating 285 Providing & Fixing of ISO certified company made Four Pole By pass Change Over Switch conforming to IS:13947(Part 3) : IEC:60947-3-1 and IEC:60947-6-1, Open execution type in the following ratings.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR .100 A 286 Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load andsite requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting ofclass 3 as per IEC,minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted inexisting distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above ratingincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSRSingle pole MCB (With B/C curve tripping Characteristics) 0.5 A to 5 A rating 287 Double pole MCB(With B/C curve tripping Characteristics) 6 A to 32 A rating 288 Four pole MCB (With B/C curve tripping Characteristics) 6 A to 32 A rating 289 50/63 A rating
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 2
22.
Health and Family Welfare #10363172 Price Bid
Tender For Electrification Work In Phc Building At Khetasar Block Osian District Jodhpur; 1 (Electrical BSR 2022 Rajasthan) Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)inrecessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit & itsISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thickHot Dipped Galvanized Modular Box with earth terminal, 10A Modular switch,Modular face plate with grid plate, 3 pin ceiling rose / Holder /3 way connector, screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR. Short point (up to 3 mtr.) 2 Short point (up to 3 mtr.) 3 Medium point (up to 6 mtr.) 4 Long point(up to 10 mtr.) 5 Wiring of twin control light point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)in recessed ISI markedMMS ( IS:9537 P - III ) PVC conduit & its ISI marked (IS:3419-1988) accessories, round tiles, 2 Nos Hot Dipped Galvanized M.S Modularbox of 1.2 mm thickwith earth terminal,2 Nos10 A two way Modular switch, 3 pin ceiling rose / holder / 3 way connector ,Modular face plate with grid plate,screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR 6 Medium point (up to 6 mtr.) 7 Long point(up to 10 mtr.) 8 Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal sizeFR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) inrecessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & its ISI marked (IS:3419-1988)accessories, Hot Dipped GalvanizedModular box of 1.2 mm thick with earth terminal, 10 A modularswitch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR 9 On board 10 Supplying and fixing of power plug point with Modular accessories as per PWD specification for electrical Works, on hot dipped galvanized modular box of 1.2 mm thick with earthing terminal/connector on surface or in recessed with suitable size of modular face place with grid plate and cover plate including cost ofISI marked modular 16 amp. Switch (IS :3854) and 6/16 amp. socket outlet (IS:1293) making connection , testing , etc. as required. For specification ofWiring accessories refer ChapterE - 07related item & For additional technical parameters of product / work refer Annexure A attached with this BSR 11 Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 forlower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5,in existingsurface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure A attached with this BSR 12 3x 1.5 sq.mm 13 2 x 2.5 sq. mm. + 1x1.5sqmm 14 2 x 4.0 sq. mm. + 1 x 2.5 sq. mm. 15 4 x 10.0 sq.mm 16 4 x 6.0 sq.mm 17 1 x 2.5 sq.mm 18 Providing & Fixing of Recessed/surface mounting heavy duty horizontal type Double Door ( Metal / Glazed )Distribution board with Metal end box made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3, powder painted complete with reversible door (for double door DB only )100 amp. insulated copper bus bar/shorting link , copper neutral link, copper earth link , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, Ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 19 Metal door (Three phase) Per phase isolation, Horizontal IK-09 and IP-43 with Metal end box 20 6Way(Incomer 8,Sub Incomer2+2+2) 21 Metal door (single phase) IK-09 and IP-43 with Metal end box 22 16 Way (16+2) 23 Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load andsite requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting ofclass 3 as per IEC,minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted inexisting distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above ratingincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 24 Single pole MCB (With B/C curve tripping Characteristics) 25 6 A to 32 A rating 26 Four pole MCB (With B/C curve tripping Characteristics) 27 40 A rating 28 Double pole MCB(With B/C curve tripping Characteristics) 29 6 A to 32 A rating 30 S&F following sizes (dia.) of ISI marked virgin material MMS ( IS:9537 P - III ) PVC conduit along withISI marked (IS:3419-1988) accessories as requiredinrecessincludingcutting the wall, covering conduit and making good the same as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 31 20 mm 32 25 mm 33 P & F phenolic laminated sheet 2.0 mm thick of following size . Including screws, cup washer as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 34 75 mm dia 35 Providing & Fixing of modular type 120 W Step Fan regulator duly ISI marked (IS 11037:1984 ) with CM/L no. printedmade out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating ,includingall as per pre approved by Engineer in charge,making connections, testing etc. as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 36 5 step fan regulator 2 Module 360 dgree rotating 37 P & F 1.2mm thickM.S. Recessed fan box, hexagonal/ round of size 130 mm dia, depth 75mm,12 mm dia rod fan hook with 100 mmlength extended on each side . All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure A attached with this BSR 38 Providing & Fixing of Heavy duty capacitor start, copper woundDouble ball bearing900/1400 RPM single phaseExhaustfan conforming to IS:2312 ISI marked in existing opening including making connections testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 39 300 mm sweep(900/1400 RPM) 40 Providing & Fixing of IP20 SMD Mid Power LED batten type integrated light fixture made from Powder coated Extruded aluminiumhousing with in built driver, System lumen efficacy ≥ 110 lm/Watt output, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, CRI >80 , life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , Maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 41 1170mm(+/-10%) LED batten with min. lumen output 2200 lm 42 Providing & Fixing ofBEEStar rated copper wounded double ball bearing capacitor start, aluminium body & Metallicblade ceilingfanConforming to all the performance requirements laid down in IS 374:2019 including all amendments, as applicable ; & Carry BIS licensing (i.e. ISI marking) with down rod up to 80 cm with secondary support safety cable ( steel rope) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 43 1200 mm Sweep BEE 1 Star rated (service value >=4.0 to < 4.5 ) 44 Providing & Fixing ofof Double ball bearing, copper wounded capacitor startsingle phase metallicblade fresh air fan, in existing opening including cost of hardware , flexible 3 core copper conductor ,making connections, testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 45 225 mm sweep 46 Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed ArrmouredAluminiumcable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV withH4- Grade electrolyticaluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) includingtesting etc. as required of following size. OEM must have its own in house NABL accrediated Laboratory for testing procedure as per IS:10810.For additional technical parameters of product / work refer Annexure A attached with this BSR 47 25.0 Sq. mm 48 3.5 core 49 6.0 Sq. mm 50 2 core 51 Add Extra for Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV gradedirect in ground including excavation of trench of size 75 cm (Depth) x 35 cm(Width) ,with procedure as per followingpoints:- (a) Make a river sand bed of height 125 mm along the trench,(b) Lay the cable in the middle of the trench,(c) Provide river sand bed of height 125 mm on top of the cable, (d) Lay the protective Common burnt clay F.P.S. Bricks of Class designation 75 / Sand stone slabs of 50 mm thicknessand 225 mm widejust above the sand bed vertically across the cable ( Approx. 9 no. Bricks per Mtr.), (e) Backfill the excavated soil leaving 300 mm from the Ground level, (f)Lay the Cable warning tape and again back-fill the remaining portion of the trench upto the ground level and compacting the earth 52 Add Extra in item no. 11.1 to 11.4 for Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. 53 Up to 35 Sq.mm fixed with 25 mm x 2 mm thick suitable length red oxide and enamel painted MS clamp and base, pvc rawl plug and screws of sufficient size with spacing 0.6 Mtr. Between Clamps. 54 Supplyandinstallationofhigh tensile low carbon steel rod molecularly bonded with 99.9 % Copperthickness (250 microns) andconfirming toUL 467, IS/IEC 62561-2of following size and length and as per point mentioned (a), (b), [c), (d), (e) below :- 55 (a) Bore a hole of dia. 100 mm of required length, Place the rod in the centre of Hole 56 (b)filled with anti corrosiveconductivecompounds with the permanent sealings at both the ends, CPRI/ ERDAtested with RMS capacity of minimum 30 KA for withstanding 1 second .To ensure the moisture content and electrical conductivity, 25 kg for 2000 mm & 50 Kgs for 3000mm of resistance lowering earth enhancement material shall be used as a backfill compound. The compound shall be tested form NABL acredeated labfor lowresistivity ( less than 0.12 Ohm - meter ) & high conductivity in nature with carbon as a major contentas per referance of IS 3043-1987,IEEE 80-2013 (clause 14.5d) , IEEE 837 & IER 1956 with latest amendemnts 57 © Connect the rod with copper Strip/Conductor/Wire with suitable clamp made from tinned copper and SS 304 Bolt 58 (d) Place Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height250 to 300 mm. 59 (d)Testing of earth resistance for value of 5 ohms or lessas required & must record by engineer in charge during site visit and ensure to enter in measurment book. 60 (e) Test certificatesfor confirming above standards from OEM is mandatory. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 61 17.2 mm thick and 3 Mtr. Long 62 Supply & Laying following size earth wire in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles,making connection with GI/Cu purity purity >95%thimble etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 63 8 SWG G.I. ( Hot Dipped) Wire 64 Providing & Fixing of IK08, IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminummaterial with heat dissipation fins on housing with UV stabilized PC (UV stablization report submitted for UV cover ) /Toughened Glass coverand secondary lens on each LED & should be SMD type of 3 to 5 watt each . The System efficacy >=125 lm/ wt and potted driver& has a unique BIS R number withInput Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety , Power Factor >0.95 driverEfficiency >85%,THD(I) <10%Humidity 10% to 90% RH Working Temp -5C to 45C .driver current <750mA. The luminaireshall be BIS certified and Trade mark certified. Life ExpectancyEqual or more than 50000 burning hrs with Minimum 70% lumen maintened , CRI >70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external inside driver compartment. driver should be Phase to phase protection of 440 V for 4 Hrs.Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities forLED fixtures.(LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 65 LED Street Light fixture with Minimum lumen output 2450 lm 66 Providing & Fixing of Street light bracket made out from following size of B class , Medium class G.I. Pipe confirming to IS : 1239 P - 1 ( 2004 ) with heavy duty pole clamp, Saddles suitable fastners etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 67 25 mm Dia. 68 SITC of3 /4pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant materialhaving following current rating, short circuitbreaking capacityat 440/415 V, 50 Hz; O/L & S/C settings , conforming to IS/IEC 60947 P -2 :2003 with frontface and centralised adjustable, trip free mechanisum, true contact position indicator,line load interchangeability,designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree,pollution degree 3, having positive isolation capability, push(test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% Icu. U imp =8 KV, rated insulation voltage690 V.provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connectionsetc. as required.OEM shall have submitNABL / CPRI / ERDA accrediated lab type test certificate before execution All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 69 4 pole MCCB With Thermal Magnetic release 70 up to 100 Amp , 25 kA, adjustable O/L & adjustable S/C setting, 71 160 Amp , 25 kA, adjustable O/L & adjustable S/C setting, 72 Providing & Fixing of ding dong/musical chime bell as per PWD specification for electrical Works, including making connection testing etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 73 P&F metal clad / Plastic industrial plug top & socket unit with pin and sleeve type contact on porcelain/ bakelite base in Recessed/surface mounting heavy duty Enclosure made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3. powder painted (without MCB) including making connections, testing etc.as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 74 32 amp, 5 pin + scrapping Earth, 8 Module 75 Providing & Fixing of ISO certified company made on load change over switch, front handle operated, four pole 415 V as per PWD specificationfor electrical Works conforming to IS/lEC 60947-3 : 1999 including connections , testing etc. as required .in the following rating.Appropriate type test certificate / OEM test report shall be submitted .All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 76 Open execution type 77 63 A 78 Supply , Installation, Testing and Comissioning ofInverter type Air Cooled Hi Wall split type Air conditioners with latest star rating system as per BEE amended upto date complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU), R-32/R-410 Green Refrigerant, wireless Remote control, suitable for working between 230V +/- 10% with low & high voltage cutoff and50 hz , single phaseACsupply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 79 1.5 TR ISEER not less then 3.8 80 2.0 TR ISEER not less then 3.8 81 Providing & Fixing of IS : 4985 - 2000 Class -4 (10 Kgf / Sqcm) UPVC drain water piping withfittings (IS:7834 & 10Kgf/sqcm) like elbow, socket, Tee, solvent cement jointing,support with MS hanger on ceiling or recessed in wallwith chasing & plastering with 6 mmthickclosedcellelastomeric nitrile rubberinsulation including leakage testing etc. as required of following Nominal sizes. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 82 25 mm 83 Supply & fixing MS powder coated stand suitable for 1.0/1.5/ 2.0 Tr outdoor type of Split AC.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 84 Making hole in stone masonary/ RCC wall/ RCC slab with core cutter for accomodating refrigerant pipe/ drain pipe/ MS pipe/ cables etc of following dia 85 150 mm dia per running inch length 86 Supply, Fixing and testing of following capacity ISO certified company made wall mounted stabilizer having output voltage variation from 200 V to 250 V(+/-5%) with input voltage variation from 170 V to 260 V, time delay facility from 2 to 4 minute and high cutoff at 270 V with providing of 16 Amp /20 Amp Industrialplug top making connection etc complete in all respect.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 87 4 kVA 88 5 kVA 89 Providing & Fixing of IP-20 LED Recessed / Surface Mounted, Round / SqaureSMD Mid Power LED Downlight with power coated die-cast aluminum housingwith UV Stabilized non yellowish Diffuser withBIS complience 2.5 KV surge protected Isolated driver, with Short & Open circuit protection, having efficiency > 85% . System Lumen efficacy of ≥ 110 lm / watt, THD < 10 % , Pf.≥0.95, CRI >80,life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. 90 OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 91 Surface Mounting (with extruded alumn. Housing ) 92 Minimum lumen output 1950 lm 93 SITC of Monoblock motor pump set ISI marked (IS:9079-2002) with TEFC motor, motor should be IE2 class as per IEC 60034-2-1: 2007, IEC 60034-30: 2008,& IS12615:2011. with Stainless steel Impellor, Stainless steel shaft, Mechanical seal, Single/Three phase ( 240 - 440 V ) permanent split capacitor type (PSC), fitted with thermal overload protection, Including cost of hardware etc on existing platform complete. Pump shall have following HP Rating, phase, Head, minimum Discharge respectively complete in all respect. OEM shall have submitNABL / CPRI / ERDA accrediatedlab type test certificate before execution. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 94 1.0 HP, 1-Ø, (10-120)Mtr, (30-12) LPM 95 Supply & Fixing of Dry Powder Agent (as per IS 4308:2019), ABC typeFire Extinguisher (Stored Pressure type) conforming to IS:15683:2018 , Powder coated Internal & External Surface Deep drawn cylinder body of Mild Steel CR2 grade conforming to IS: 513, Squeeze grip Forged brass release valve with Inbuilt safety release device, Diaphragm Type, 0 to 28 bar range pressure gauge, 450 mm long EPDM discharge tube, QR code for Product Traceability including Fixing on wall with suitable Anchor Fasteners as required of following capacity. Test Certificates of all the Parameters along with Hydro test & Burst test (For Cylinder Body) Certificatefrom OEM / External NABL Accrediated Lab is to be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 96 4 kg 97 Providing & Fixing of Vertical(BEE 5 star rated) / Horizontal( BEE 3 star rated) storage water heater with outer casing made of Engineering Plastic sheet (Upto 25 Ltr) / Metal rust proof Body (35 & 50 Ltr), Glass - line / Titanium Enamel coated Pressure Pump Compatible 8 bar pressure Inner tank, Glass Line Coated , mineral filled heating element, stem type, snap actionadjustable thermostat , Dual indicating lampsInjected PUF insulation, Multi Function Valve etc. as required held in position with 2/4 no. 10/12 mm anchor Fastener, duly wired with 3 core 2.5/4.0 Sqmm PVC insulated & sheathed copper conductor and 16 A/25A three pin plug top with Portable Residual Current Device ( PRCD ) , including making inlet, outlet Flexible alloyconnection, testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 98 15 Ltr. 99 Supplying and drawing PE Insulated & PVC Sheathed unarmoured telephone cable with 0.5 mm dia. Solid Annealed electrolytic grade bare Copper Conductor as per IS: 8130/84 &confirming to TEC specification GR / WIR/06-03 March 2002in existingsurface or recessed conduit/casing capping. including ferruling on each pair for Identification etc. as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 100 2 pair 101 P & F Krone module with base framein the recess / surface made out of 1.2 mm thicksheet steel box, front openable, having locking arrangements duly powder painted,including dressing, ferrulingandpunchingof telephone cable with krone tool etc. as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 102 10 Pairs 103 Providing & Fixing of following modular accessories as per PWD specification for electrical Works,made out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating , includingall as per pre approved by Engineer in charge,making connections, testing etc. as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 104 RJ-11 telephone jack singleline 105 Supply, Drawing and Testing of 4 pair, 23 AWG Solid Bare Copper wire insulated with PVC, UTP (Unshielded Twisted Pair), Category 6, Class E, 100 Ohm Impedance, Indoor Cable as per latest ammendments of ANSI/TIA/EIA-568 , The copper conductors should be balanced twisted in pairs, seperated by a cross-member fluted pair divider & protected byPVC Jacket. Certified performance in a 4-connector configuration upto 100 Mtrs channel requirements & transmission frequencies up to 250 Mhz. in existing MS/PVC Conduits/casing capping including making connections to Information outlets and Patch Panels with jack &ferruling at both ends for identification with necessary tools for punching, stripping, crimping and testing etc as required complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 106 Supply and Installation of unsheilded/360 degree sheilded Information outlets made of high impact plastic body with ABS, FR Grade halogen free material with provision for protection against dust in jack, suitable for Cat 6/6A application complying to latest ammendments, According. to Cat. 6/6A channel, It should support channel as well as components requirements of Cat.6/6A standards at frequencies of up to 250 to 500 Mhz. Cat 6/6A unshielded/shielded Jack should be suitable to terminate 4 pair, 23/24 AWG solid/stranded wire diameters, using 100 Ohm unshielded/shielded balance twisted pair cable, the jack should have tooless/impact termination on reliable copper tin plated Insulation displacement contact, with easy lock mechanism, It supports IEC 60603-7-4 and complied with ANSI/TIA/EIA 568 C.2 standard. jack should be RJ11,RJ12 & RJ45 compatible. Should support Ethernet 1.2 Gb/s ATM,Digital video and broadband/baseband analog video, Voice over internet protocal (VOIP) Specifications in existing modular/MS Boxes along with necessory connections as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 107 Cat 6, Un-sheilded Information Outlet 108 Supply & fixing of square Faceplate for Flush / Surface Mount Information Outlets Single/Dual or Quad Aperture ,material should bePC+ABS body, Suitable for RJ45 unshielded/shielded connection modules. Should match with I. O. OEM. Dimensions should be 86mm X 86mm as required complete in all respect.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 109 Single Aperture 110 Supply & Installation of IP-20 & IK-08 , UL ListedWall mounted Double Section Communication enclosure (Rack) made from powder coated (60 to 80 Micron) CRCA sheet, front sturdy sheet steel frame folded from one piece and welded with minimum 5mm toughened glass door,Vertical Mounting Rail 1.6 MM with UMarking , with All round protective channel on the door aperture, lock integrated on front door, top and bottom cover with cable entry provision with gland plates, integrated side walls, 2 pair of 19 angles with wall mounting provision on wall. Accessories like: 1 No of 19 1U Horizontal Cable manager, 1 No of 90 cfm 230V AC Fan with 1 mts long cable, mounting hardware , 1 No of 19 1U, mountable socket strips with 5 nos of 5A universal sockets with 2 mts long power chord for supplying power to switches, fans etc along with earth continuity kit, indicator, moulded power supply cable. fixing on wall with Suitable Anchor fastneretc as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 111 6 U Rack with Width 600 mm &Depth 400 mm + 100 mm 112 Supply, Installation, Testing and Comissioning of Rack mounted 19 1U, Cat6 24 Port loaded, 1.5-1.6 MM CRS chasis, powder coated, sheet steel, made of plastic (ABS), Modular Patch Panelswith Rear Cable management system and mounting hardware to mount the patch panel. Should have port identification numbers printed/engraved on front of the panel. Etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 113 Modular Patch Panel Loaded with Cat -6 I/O 114 Supply , Installation, Testing and Comissioning ofUnmanaged Switch Plug-and-play - easy setup with no configuration or no software needed, following Port fast ethernet - 8 port 10/100 MBPS auto-negotiation RJ45 ports,IEEE 802.3x flow control ,supports auto-MDI/MDIX, eliminating the need for crossover cables including making connection etc as required complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 115 24 Port 116 Providing & Fixing of IP20, 2x2 LED Surface/ Recessedmounting Mid power SMD type LED Light fixture not less than 50mm housing depth made from CRCA sheet steel housing, high purity / transmisivity UV stabilized Non -yellowish diffuser for uniform light distribution. High efficiency with 4 KV internal/external surge protection BIS certified isolated driver having efficiency > 85% , with Short & Open circuit protection(Integral with light fixture). System lumen efficacy of ≥ 120 lm/Watt ,THD < 10 % , p.f.≥0.95,CRI >80 ,life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. 117 OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted.All as per pre approved by Engineer in charge. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 118 Recessed Mounting 119 Minimum lumen output 4200 lm 120 Supply , Installation and Testing of 4 pair, 100 Ohm impedance, Cat 6/6A /Class E/Ea patch cords should be constructed of minimum 23/24 AWG, stranded bare Copper cable with FRPVC/LSZH Jacket, with an enhanced performance by factory moulded RJ45 connectors with strain relief boots as per ANSI/TIA/EIA 568-C.2 suitable for Cat 6/6A application complying to latest ammendments Category 6/6A Standards, According. to TIA568C.2, ISO/IEC 11801, EN 50173, IEC 60603-7-51, EN 60603-7, IEEE 802.3an minimum requirement for 1G BASE-T to 10G BASE-T performance. Patch cords shall be straight thru cable compatible with both T568-A and T568-B wiring schemes, should support IEEE 802.3af / IEEE 802.3at for POE applications, Minimum 750 to 1000 mating cycles in plug contacts for long durability, Should support Ethernet 10GBASE-T, 1.2 Gb/s ATM, Token ring 4/16, Digital video and broadband/baseband analog video, Voice over internet protocal (VOIP).All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 121 Cat 6, U/UTP (Unscreened/Un-sheilded Twisted Pair) Patch Cord 122 1 Mtr 123 Supplying and making one end termination with Nickel plated heavy duty brass single compression gland (as per IS 12943-1990)) SIBG type consisting of Check Nut, Gland Body, Metal Washer(3 Nos.), Outer Seal Rubber Ring,Compression Nut,heavy duty aluminium lugs (as per IS 8309 -1993) duly crimped with crimping tool, PVC tape as perIS 8337-1976offollowing size ofPVC insulated & PVC sheathed/ XLPE aluminium conductor cable of 1100 volt grade as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 124 3.5 x 25.0 sq.mm 125 Supply, installation, testing and comissioning ofinterconnectingcopperrefrigerant pipingof DHE Grade C12200- ASTM B68, B75, chemical composition of copper %- 99.0 Min and Phosphorus %- 0.015 to 0.040 . For Annealed copper tube :- Tensile strength = 210 Mpa wih elongation % = 40 Min . Ink MarkBrand Printing on Hard Tubes should be present. duly insulated with tubular elastomeric nitrile rubber FM/UL approved with high water vapor diffusion resistance and low thermal conductivity should be certified Class O in Fire Propagationas per BS 476 Part 6 including chase cutting andfilling with mortar, Slotted channel supports mounted on 10 mm threaded rod at suitable spacing the exposed piping shall be wrapped with glass woven cloth and lag coating for vapour barrier and weather protection. Joints shall be covered with nitrile rubber tape of 3 mm thick complete as required of following sizes. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 126 12.7 mm O.D., wall thinkness ≥ 0.8mm (insulation – 13 mm thick) 127 6.4 mm O.D., wall thinkness ≥ 0.8mm (insulation – 13 mm thick) 128 Supply , Installation, Testing and Comissioning of IS:1475 marked self contained drinking water cooler withhermeticallysealed compressor,non CFC refrigerent suitable for operation on 230V/1pH/50Hz AC supply,Full stainless steel (SS304)body (0.8 mm thick)and tank (0.5 mm thick) , stainless steel water tray,minimum two nosBrass Chrome plated faucets and suitable drainage system complete in all respect with requiredheight MS fabricated and Painted Angle iron frame( Cost of frame to be paid Extra )complete in all respect of the following capacity.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 129 cooling capacity 150 Ltr./Hr. and storage capacity 150 Ltrs 130 Providing and fixing welded mesh/expanded metal mesh 25 mmx 25 mm x 3mm in frame work, flat iron beading 20x3mm including top cross laps inside and out sides welding, iron bolts, crews, clips etc. including two coat of red oxide and two coat of enamel paint or more requiredcomplete with frame work with 50 X 50 X 6mm angle iron post 30 cm in ground embeded in cement concrete 1:3:6 (30X30X45cm) at corner and every three mtr including painting with one coat of primer and two coat of enamel paint work will be done as per direction of engineer incharge of sizecomplete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 131 SITC of IP-42 and general construction confirming to IS:8623 : 1993, wall/ free standing floor mounted dust and vermin proof compartmentalisedcubical panel as specifications andOther parameters requiredas per point (a) ,(b), (c),(d), (e), (f), (g), (h) as below:- 132 (a)Thickness of CRCA sheet shallbe 2.0 mm,cable alley compartments having concealed hinged type doors with key type lock with / withoutdetachable extension type structure. Removable 3 mm. thick sheet steel gland plates with appropriate size of knockouts for cables shall be provided 133 (b)complete panel shall undergo a process of degreasing, Water rinsing, Activation, derusting,pickling in acid bath, phosphatising & shall be subjected to nine tank process and then Powder coated with approved shade of minimum 70 microns on both side of panel.The panel having PE foam/ Neoprene rubber gasket of not less than 3mm thickness ,required hardware , concealed hinged door with key type locking arrangement for equipment/switchgear earthed with 2.5 sq.mm braided copper wire. 134 [c)Interconnection between bus bar and switchgears /cable shall be rigidly supported and made out by flexible copper wires (up to 63 amp ) and by solid bus bar(>63 amp ) . control wiring will be carried out with 1.5 Sq.mm, Earth wire with 2.5 Sq.mm and CT with 2.5 sq.mm flexible copper wire only.All joints / interconnections of copper bus bar shall be dully tinned . Clearance between main bus bar and risers / metal parts shall be at least 10 mm additional to width of bus bar Bus bar is insulated by Heat Shrinkable sleeves . Earth and Neutral bus bar shall be half of the size of phase bus bar. ( Cost of Bus bar/ Flexible wire for Interconnection between Main busbar and Switchgearis to be Paid Extra ) 135 (d)Wiring between components within switchgear and Incoming / outgoing cableshall be done through the terminal block only. Direct connection shall not be permitted. Each terminal block shall be one piece moulded, barrier type, 650 volt grade, complete with washers, heads, studs with two nuts and identification strips and shall have adequate continuous current rating. For tap-offs, adjacent terminals with shorting strips shall be used. 10% Spare terminal blocks shall be provided. Wire identification on marking strip shall correspond to the designation of the wiring diagrams. All wire terminals on the equipment shall also be marked with designation corresponding to those of the wiring diagram. 136 (e)All wiring shall be enclosed in plastic channels and neatly bunched and closed in metering chamber, Wiring between terminals of various devices shall be ‘point to point’ (no wire splitting or tee connections) with wires neatly trucked along the back of the panels, adequately supported to prevent sagging. 137 (f)Floor mounted panel shall be mounted on Base frame of ISMCchannel size 100 x 50 x 5 mm( to be paid Extra ) 138 (g) Tests: The insulation resistance (with 1000 V Megger) and High voltage Power frequency test (by applying a voltage of 2.5KV for one minute) shall be measured between phases, between phase and neutral and between phase and earth. both before and after high voltage power frequency test. The insulation resistance shall not be less than three megaohm. CT Secondary current injection test shall also be carried out. 139 (h) only outer surface area on all sides shall be measured & panel to be fabricated only from CPRI approved fabricator only (CPRI Test certificates to be submitted)All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 140 Providing & Fixing of BIS approvedCurrent Transformeras per PWD specification for electrical Works ,ISI marked as perIS 2705-1992/ conforming to IEC 60044-1, with secondary terminalof CT shall be brought out suitable to a terminal block which shall be easier accessible for testing and terminal connection , with all necessary support in existing panel including connection etc. as requiredCurrent transformer Ring Type Tape Wound/Resin Cast Wound as per IS 16227 with, Accuracy Cl, CT ratio and burden as specified. ISF<=5, Cu cross section of secondary wire 1.5sqmm (minimum), including all necessary support in existing panel including connection etc. as required . All as per pre approved by Engineer in charge.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 141 Ring type tape wound CT 142 C T Class 1, Ratio 200/5 to 300/5, Burden 10 VA 143 Providing & Fixing of110/220 V, unibody LED Indicatinglamp IEC 60947with integral circuit, IP 65 above panel &IP 20 terminal block, Approx. body dia for panel not less then 20 mm, length min. 50mm, front LED cover dia min.29 mm, contact material phospher bronze for Led, PCB contacts shall be ofbrass (tin plated), impulsedielectric tested for 2.5 KV, Rated insulation resistance shall be 100 M ohm at 500VDCincluding connection etc. as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 144 Red/yellow/Green colour 145 Supplying and fixing of Aluminium (IEC 60105 ISO 209-1,2) / Copper (IEC 60028) bus bar by means of SMC / DMC type insulatorwith standard short circuit withstand capacity, high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable PVC sleeves. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 146 Electrolytic grade Aluminium bus bar 6010 grade 147 Providing & Fixing of 240/415 V factory fitted RCBO with overload, short-circuit and earth leakage protectionwith ISI marked (IS12640-2)/ conforming to IEC 61009-1, breaking capacity 10 KA,provision for pad lock, min. Electrical operation 10,000 upto 63 A rating , minimum phase termination capacity of 35sq.mm. , IP 20 contact protection with existing distribution board / sheetincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 148 Two pole 100/300mA sensitivity 149 40 A rating
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 1
23.
Housing Urban and Rular Development #10350279 Price Bid
Tender For Construction Of Labour Ward In Hostpitalgangashahar - Bikaner ( Electricalwork ) Construction Of Labour Ward In Hostpital Gangashahar - Bikaner ( Electricalwork ) - 1 Note:-Please read Annexure A for each Items if not uploaded in e tender, see on pwdraj website.Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit & its ISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thick Hot Dipped Galvanized Modular Box with earth terminal, 10A Modular switch,Modular face plate with grid plate, 3 pin ceiling rose / Holder /3 way connector, screws, making connections, testing etc. as required. For specification of copper Conductor, Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR 2 Short point (up to 3 mtr.) 3 Medium point (up to 6 mtr.) 4 Long point(up to 10 mtr.) 5 Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & its ISI marked (IS:3419-1988)accessories, Hot Dipped Galvanized Modular box of 1.2 mm thick with earth terminal, 10 A modular switch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required. For specification of copper Conductor, Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR 6 On board 7 S&F following sizes (dia.) of ISI marked virgin material MMS ( IS:9537 P - III ) PVC conduit along with ISI marked (IS:3419-1988) accessories with own OEM CM/L No. as required in recess including cutting the wall, covering conduit and making good the same as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 8 20 mm 9 25 mm 10 32 mm 11 Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from 99.90 % purity copper, class 2 stranding in acc. to IS:8130/IEC 60228 for lower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5, in existing surface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure A attached with this BSR 12 1 x 1.5 sq.mm 13 2 x 2.5 sq. mm. + 1x1.5sqmm 14 2 x 4.0 sq. mm. + 1 x 2.5 sq. mm. 15 1 x 6.0 sq.mm 16 4 x 16.0 sq.mm 17 Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load andsite requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting ofclass 3 as per IEC,minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted inexisting distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above ratingincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 18 Single pole MCB (With B/C curve tripping Characteristics) 19 6 A to 32 A rating 20 Four pole MCB (With B/C curve tripping Characteristics) 21 50/63 A rating 22 Providing & Fixing of Recessed/surface mounting heavy duty horizontal type Double Door ( Metal / Glazed )Distribution board with Metal end box made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3, powder painted complete with reversible door (for double door DB only )100 amp. insulated copper bus bar/shorting link , copper neutral link, copper earth link , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, Ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 23 Metal door (Three phase) IK-09 and IP-43with Metal end box 24 6 Way 25 Providing & Fixing ofISI marked (IS:1293) 16 ampunbreakable 3 pin plug top having lamp indicator with CM/L no. printed and made out from industrial grade Polycarbonate or fire resistant ABS material, brass terminal including making connection testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 26 Providing & Fixing of modular type switch/ bell push duly ISI marked (IS :3854) with CM/L no. printed and made out of unbreakable and fire retardant vergin UV Stabilized Polycarbonate with brass terminals and captive screws & silver alloy contact tip with IP-2rating ,minimum width of switch toggle( PUSH PART ) should not less then 20mm, including all as per pre approved by Engineer in charge,making connections, testing etc. as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 27 25 Amp.2 Moduleswitch With LedIndicator 28 Providing & Fixing of modular type lockable feature socket dulymade out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating , includingall as per pre approved by Engineer in charge,making connections, testing etc. as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 29 25 Amp. 2 Module Socket 30 Providing & Fixing of modular type 100/120W Step Fan regulator duly ISI marked (IS 11037:1984 ) with CM/L no. printed made out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tip with IP-2rating , including all as per pre approved by Engineer in charge,making connections, testing etc. as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 31 5 step fan regulator 2 Module 32 Providing & Fixing of following modular accessories as per PWD specification for electrical Works,made out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating , includingall as per pre approved by Engineer in charge,making connections, testing etc. as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 33 Blanking plate 34 Modular MCB 6 A to 32 ASP 35 Providing & Fixing of following size mounting grid plates with cover plates made from fire retardent UV established high performance engineering plastic suitable for all universal metal boxes for front installation & removal direct fit type complete in all respect.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR 36 1/2 Module 37 3 Module 38 Providing & Fixing ofWiring Accessories OEM fabricated following size GI box of 1.2 mm thick with earthing terminal and adjustable floating clamp in recess/ surface suitable for modular accessories as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 39 1-2 Module 40 3 Module 41 Providing and fixing of power plug point with non modular accessories as per PWD specification for electrical Works withGalvanized box of 1.2 mm thickwith earth terminal with suitable size phenolic laminated sheet (IS : 2036 -1995) cover including cost of 16 amp. Switch (IS :3854) and 3/6 pin 16 amp. socket outletmaking connection , testing , etc. as required. . For specification ofWiring accessories refer ChapterE - 07 related item &For additional technical parameters of product / work refer Annexure A attached with this BSR 42 Supplying and fixing of power plug point with Modular accessories as per PWD specification for electrical Works, on hot dipped galvanized modular box of 1.2 mm thick with earthing terminal/connector on surface or in recessed with suitable size of modular face place with grid plate and cover plate including cost ofISI marked modular 16 amp. Switch (IS :3854) and 6/16 amp. socket outlet (IS:1293) making connection , testing , etc. as required. For specification ofWiring accessories refer ChapterE - 07related item & For additional technical parameters of product / work refer Annexure A attached with this BSR 43 SITC of IP-42 and general construction confirming to IS:8623 : 1993, wall/ free standing floor mounted dust and vermin proof compartmentalisedcubical panel as specifications andOther parameters requiredas per point (a) ,(b), (c),(d), (e), (f), (g), (h) as below:- 44 (a)Thickness of CRCA sheet shallbe 2.0 mm,cable alley compartments having concealed hinged type doors with key type lock with / withoutdetachable extension type structure. Removable 3 mm. thick sheet steel gland plates with appropriate size of knockouts for cables shall be provided 45 (b)complete panel shall undergo a process of degreasing, Water rinsing, Activation, derusting,pickling in acid bath, phosphatising & shall be subjected to nine tank process and then Powder coated with approved shade of minimum 70 microns on both side of panel.The panel having PE foam/ Neoprene rubber gasket of not less than 3mm thickness ,required hardware , concealed hinged door with key type locking arrangement for equipment/switchgear earthed with 2.5 sq.mm braided copper wire. 46 [c)Interconnection between bus bar and switchgears /cable shall be rigidly supported and made out by flexible copper wires (up to 63 amp ) and by solid bus bar(>63 amp ) . control wiring will be carried out with 1.5 Sq.mm, Earth wire with 2.5 Sq.mm and CT with 2.5 sq.mm flexible copper wire only.All joints / interconnections of copper bus bar shall be dully tinned . Clearance between main bus bar and risers / metal parts shall be at least 10 mm additional to width of bus bar Bus bar is insulated by Heat Shrinkable sleeves . Earth and Neutral bus bar shall be half of the size of phase bus bar. ( Cost of Bus bar/ Flexible wire for Interconnection between Main busbar and Switchgearis to be Paid Extra ) 47 (d)Wiring between components within switchgear and Incoming / outgoing cableshall be done through the terminal block only. Direct connection shall not be permitted. Each terminal block shall be one piece moulded, barrier type, 650 volt grade, complete with washers, heads, studs with two nuts and identification strips and shall have adequate continuous current rating. For tap-offs, adjacent terminals with shorting strips shall be used. 10% Spare terminal blocks shall be provided. Wire identification on marking strip shall correspond to the designation of the wiring diagrams. All wire terminals on the equipment shall also be marked with designation corresponding to those of the wiring diagram. 48 (e)All wiring shall be enclosed in plastic channels and neatly bunched and closed in metering chamber, Wiring between terminals of various devices shall be ‘point to point’ (no wire splitting or tee connections) with wires neatly trucked along the back of the panels, adequately supported to prevent sagging. 49 (f)Floor mounted panel shall be mounted on Base frame of ISMCchannel size 100 x 50 x 5 mm( to be paid Extra ) 50 (g) Tests: The insulation resistance (with 1000 V Megger) and High voltage Power frequency test (by applying a voltage of 2.5KV for one minute) shall be measured between phases, between phase and neutral and between phase and earth. both before and after high voltage power frequency test. The insulation resistance shall not be less than three megaohm. CT Secondary current injection test shall also be carried out. 51 (h) only outer surface area on all sides shall be measured & panel to be fabricated only from CPRI approved fabricator only (CPRI Test certificates to be submitted)All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 52 Supplying and fixing of Aluminium (IEC 60105 ISO 209-1,2) / Copper (IEC 60028) bus bar by means of SMC / DMC type insulatorwith standard short circuit withstand capacity, high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable PVC sleeves. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 53 Electrolytic grade (Cu-ETP) Tin Coated annealed copper bus bars IACS 100% grade 54 Providing & Fixing of110/220 V, unibody LED Indicatinglamp IEC 60947with integral circuit, IP 65 above panel &IP 20 terminal block, Approx. body dia for panel not less then 20 mm, length min. 50mm, front LED cover dia min.29 mm, contact material phospher bronze for Led, PCB contacts shall be ofbrass (tin plated), impulsedielectric tested for 2.5 KV, Rated insulation resistance shall be 100 M ohm at 500VDCincluding connection etc. as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 55 Blue / white Colour 56 SITC of3 /4pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant materialhaving following current rating, short circuitbreaking capacityat 440/415 V, 50 Hz; O/L & S/C settings , conforming to IS/IEC 60947 P -2 :2003 with frontface and centralised adjustable, trip free mechanisum, true contact position indicator,line load interchangeability,designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree,pollution degree 3, having positive isolation capability, push(test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% Icu. U imp =8 KV, rated insulation voltage690 V.provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connectionsetc. as required.OEM shall have submitNABL / CPRI / ERDA accrediated lab type test certificate before execution All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 57 4 pole MCCB With Thermal Magnetic release 58 up to 100 Amp , 25 kA, adjustable O/L & adjustable S/C setting, 59 200 Amp , 25 kA, adjustable O/L & adjustable S/C setting, 60 250 Amp , 35 kA, adjustable O/L & adjustable S/C setting, 61 400 Amp , 35 kA, adjustable O/L & adjustable S/C setting, 62 Providing & Fixing of IK08 and IP-30 Recessed/surface mounting heavy duty Enclosuresuitable for mounting 3 / 4 pole MCCB, Inbuilt neutral linkmade out from Galvanized steel / CRCA sheet not less then 1.2 mm thickconforming to IS-8623-1 & 3 /IEC 61439- 1 & 3. powder painted complete with din railmaking internal DBterminations,detachable gland plate, including making connections, testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 63 Suitable to accommodate up to 70 sqmm 3.5 core Al arm. Cable 64 Providing & Fixing of ISO certified company made on load change over switch, front handle operated, four pole 415 V as per PWD specificationfor electrical Works conforming to IS/lEC 60947-3 : 1999 including connections , testing etc. as required .in the following rating.Appropriate type test certificate / OEM test report shall be submitted .All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 65 Open execution type 66 400 A 67 Providing & Fixing of ISO certified company made bus bar chamber housed in sheet metal box as per PWD specification for electrical Works Confirming to IEC-60439/ IS-8623 & IEC-60529/ IS-2147 made out from 1.6 mm thick powder coated CRCA sheet,degree of protection IP-31 front openable bus bar made out of aluminium or wrought aluminium alloy suitable for 200 amp. Capacity, bus barfixed on porcelain/DMC insulators at approved spacingincluding making connections etc. as required. Appropriate type test certificate / OEM test report shall be submitted .All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 68 450 mm long , 4 strip 69 Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Un-Arrmoured Aluminium cable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV with H4- Grade electrolytic aluminium conductor confirming to IS 8130 of purity >99.6 %, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray (with cable tie) including testing etc. as required of following size. OEM must have its own in house NABL accrediated Laboratory for testing procedure as per IS:10810. For additional technical parameters of product / work refer Annexure A attached with this BSR 70 95.0 Sq. mm 71 3.5 core 72 Add Extra in item no. 11.1 to 11.4 for Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. 73 Up to 35 Sq.mm fixed with 25 mm x 2 mm thick suitable length red oxide and enamel painted MS clamp and base, pvc rawl plug and screws of sufficient size with spacing 0.6 Mtr. Between Clamps. 74 Supplying and makingend termination with heavy aluminiumlugs ( Pin / ring type )confirming to IS 8309 -1993 & IS 8337-1976 duly crimped with crimping tool, PVC tape etc of following size.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 75 50.0 Sq.mm 76 95.0 Sq.mm 77 Supply, Fabricating & installing following sizes of perforated Powder coated MS cable tray with perforation not more then 17.5% in convenient section including horizontal and vertical bends, reducers tees,cross members and other accessories as required and duly suspended from the ceiling with GI suspenders including GI bolts & nuts , fastners, supports etc. as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 78 300mm x 50mm x 1.6mm 79 P / L of Double wall corrugated HDPE pipe confirming to IS : 16205 P-24, Stiffness Class750 N,Externally corrugated and having smooth surface insidewith HDPE Coupler, Elbow, Teeat required Depth below the ground for laying cable of followingNominal Outer dia.MFR Test reportfrom NABL accrediated is to be submitted.(Excavation of Earth& Back filling with compaction is to be Paid Extra)All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 80 63mm 81 Supply and installation of high tensile low carbon steel rod molecularly bonded with 99.9 % Copper thickness (250 microns) and confirming to UL 467, IS/IEC 62561-2 of following size and length and as per point mentioned (a), (b), [c), (d), (e) below :- (a) Bore a hole of dia. 100 mm of required length, Place the rod in the centre of Hole (b) filled with anti corrosive conductive compounds with the permanent sealings at both the ends, CPRI/ ERDA tested with RMS capacity of minimum 30 KA for withstanding 1 second .To ensure the moisture content and electrical conductivity, 25 kg for 2000 mm & 50 Kgs for 3000mm of resistance lowering earth enhancement material shall be used as a backfill compound. The compound shall be tested form NABL acredeated lab for low resistivity ( less than 0.12 Ohm - meter ) & high conductivity in nature with carbon as a major content as per referance of IS 3043-1987,IEEE 80-2013 (clause 14.5d) , IEEE 837 & IER 1956 with latest amendemnts © Connect the rod with copper Strip/Conductor/Wire with suitable clamp made from tinned copper and SS 304 Bolt (d) Place Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height 250 to 300 mm. (d) Testing of earth resistance for value of 5 ohms or less as required & must record by engineer in charge during site visit and ensure to enter in measurment book. (e) Test certificates for confirming above standards from OEM is mandatory. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR 82 17.2 mm thick and 3 Mtr. Long 83 Supply & Laying following size earth strip in horizontal or vertical run in surface by means of Earth strip DMC Insulator including riveting/ soldering/ welding, Jointing shall be done by overlapping and with 2 set of Brass (for Cu strip) / GI (for GI Strip) nut bolt & spring washer spaced at 50cm making connection etc. as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR 84 32mm x6mm G.I. ( Hot Dipped) Strip 85 Supply & Laying following size earth wire in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles, making connection with GI/Cu thimble etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR 86 10 SWG G.I. ( Hot Dipped) Wire 87 Supply & Fixing of phenolic laminated boardof 6.4 mm thick forfresh air fan/exhaust fan up to size of 300 mm onexisting window frame including cost of board, cutting of hole , Nut bolts etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 88 Providing & Fixing of BEE Star rated copper wounded double ball bearing capacitor start, aluminium body & Metallic blade ceiling fan Conforming to all the performance requirements laid down in IS 374:2019 including all amendments, as applicable ; & Carry BIS licensing (i.e. ISI marking) with down rod up to 80 cm with secondary support safety cable ( steel rope) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR 89 1200 mm Sweep BEE 1 Star rated (service value >=4.0 to < 4.5 ) 90 P & F 1.2mm thickM.S. Recessed fan box, hexagonal/ round of size 130 mm dia, depth 75mm,12 mm dia rod fan hook with 100 mmlength extended on each side complete with minimum weight of 750 gm. All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure A attached with this BSR 91 Providing & Fixing ofof Double ball bearing, copper wounded capacitor startsingle phase metallicblade fresh air fan, in existing opening including cost of hardware , flexible 3 core copper conductor ,making connections, testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 92 225 mm sweep 93 300 mm sweep 94 Providing & Fixing ofextra down rod of 15 mm dia . ERW (Electrical resistance welded ) of 1.6mm nominal thick medium duty steelpipe including cutting, threading, drilling, fixing quarter pin etc as reqd.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 95 P & F of Gravity Louver shutter of superior quality made out of frame of18 swg M.S. sheet & Louvers made from 24 swg MS Sheetwith enamel paint including cost of nuts, bolts, etc as reqd.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 96 Up to 380 mm size 97 Providing & Fixing of Vertical(BEE 5 star rated) / Horizontal( BEE 3 star rated) storage water heater with outer casing made of Engineering Plastic sheet (Upto 25 Ltr) / Metal rust proof Body (35 & 50 Ltr), Glass - line / Titanium Enamel coated Pressure Pump Compatible 8 bar pressure Inner tank, Glass Line Coated , mineral filled heating element, stem type, snap actionadjustable thermostat , Dual indicating lampsInjected PUF insulation, Multi Function Valve etc. as required held in position with 2/4 no. 10/12 mm anchor Fastener, duly wired with 3 core 2.5/4.0 Sqmm PVC insulated & sheathed copper conductor and 16 A/25A three pin plug top with Portable Residual Current Device ( PRCD ) , including making inlet, outlet Flexible alloyconnection, testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 98 25 Ltr. 99 Providing & Fixing of IP-20 LED Recessed / Surface Mounted, Round / Sqaure SMD Mid Power LED Downlight with power coated die-cast aluminum housing with UV Stabilized non yellowish Diffuser with BIS complience 2.5 KV surge protected Isolated driver, with Short & Open circuit protection, having efficiency > 85% . System Lumen efficacy of ≥ 110 lm / watt, THD < 10 % , Pf.≥0.95, CRI >80, life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR 100 Recessed Mounting 101 Minimum lumen output 1300 lm 12 W 102 Minimum lumen output 1950 lm 18 W 103 Providing & Fixing of IP20, 2x2 LED Surface/ Recessedmounting Mid power SMD type LED Light fixture not less than 50mm housing depth made from CRCA sheet steel housing, high purity / transmisivity UV stabilized Non -yellowish diffuser for uniform light distribution. High efficiency with 4 KV internal/external surge protection BIS certified isolated driver having efficiency > 85% , with Short & Open circuit protection(Integral with light fixture). System lumen efficacy of ≥ 120 lm/Watt ,THD < 10 % , p.f.≥0.95,CRI >80 ,life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. 104 OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted.All as per pre approved by Engineer in charge. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 105 Recessed Mounting 106 Minimum lumen output 4200 lm 36W 107 Supply & Fixing of Dry Powder Agent (as per IS 4308:2019), ABC typeFire Extinguisher (Stored Pressure type) conforming to IS:15683:2018 , Powder coated Internal & External Surface Deep drawn cylinder body of Mild Steel CR2 grade conforming to IS: 513, Squeeze grip Forged brass release valve with Inbuilt safety release device, Diaphragm Type, 0 to 28 bar range pressure gauge, 450 mm long EPDM discharge tube, QR code for Product Traceability including Fixing on wall with suitable Anchor Fasteners as required of following capacity. Test Certificates of all the Parameters along with Hydro test & Burst test (For Cylinder Body) Certificatefrom OEM / External NABL Accrediated Lab is to be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 108 4 kg
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
24.
Public Administrative Department #10348518 Price Bid
Tender For Maintenance Of Rajkot Circle Office Building Rajkot For Year 2025-26; 1 Execution of work under following items 2 Laying & fixing of conduit, cutting, glueing/jointing, fixing saddles/spacers, making good wall/ceiling penetrations, testing continuity and final inspection — per meter (includes testing) as per instruction of engineer in-charge. (complete SITC) 3 Removing dry/oil bound distemper and waterproof paint by scrapping, sand papering & preparing surface smooth (Interior walls – long & partition walls). 4 Supply of PVC conduit pipes (ISI marked, BEC / AKG / Precision / Pressfit / Steel Craft) and fittings (elbows, couplers, bends, boxes) — per meter. Material shall be of approved brand or equivalent approved by Engineer-in-Charge. (complete SITC) 5 Applying one coat of ready-mixed red-oxide zinc chromate primer on steel/galvanized iron work (surface prep by wire-brushing included). 6 Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 m lead (for 10–25 mm thick tiles) 7 Removal of existing tiles and excavation of protruding tree roots, filling void with compacted sand/aggregate and repairing base with cement mortar. 8 Exterior painting for boundary wall with synthetic enamel paint of approved brand to give even shade. 9 Consumables & minor items per point: screws, PVC clips, tapes, cable ties, sealing compounds, short patch cords, final cleaning 10 Silver painting over existing partitions (aluminium paint) to give even shade. 11 Spray painting over existing almirahs (steel work) with deluxe multi-surface paint; two coats @ 0.9 L/10 sqm over undercoat of primer @ 0.8 L/10 sqm. 12 Waterproof cement paint above dado (2.1 m to 2.5 m height) + Acrylic emulsion on ceiling incl. edges 13 Interior walls finishing with deluxe multi-surface waterproof paint system using primer as per manufacturer’s specification (two or more coats). 14 Finishing walls with water proof cement paint (two coats) of approved brand and shade. 15 Finishing with epoxy paint (two or more coats) on steel work (over primer) for window grills and MS gates, including surface prep and scaffolding. 16 Supply, Fixing & wiring: mounting plate, connection to point wiring, ferruling, testing & cleaning (per unit) (Labour and testing included) 17 Providing and fixing CPVC distribution pipe (20/25 mm dia) for outlet and internal distribution: Supply and fix CPVC pipe with fittings (tees, elbows, bends, reducers, clamps) from rooftop tanks to toilet blocks, wash basins & taps; include wall drilling, sealing, testing, flushing, and making good disturbed surfaces with cement mortar; pressure tested to 10 kg/cm². Material should be of approved brand by engineer in-charge. 18 P&F CPVC pipe 20/25 mm dia (supply) — ISI/approved CPVC pipe, per meter supply -inclusive of all fittings such as elbows, tees, unions, couplers, sockets, angle valves, stop valves, bib taps, outlet taps (chrome plated), pipe support and all fittings complete 19 Applying 12 mm cement plaster (single coat) on both faces of partition up to 3.5 m height, including hacking/keys where required, on walls, partition walls etc as per direction of engineer in-charge 20 Supply and fixing Coat / robe hooks (SS) — 2 nos. 21 Supply and fixing of switches & sockets (Anchor Roma / Legrand Myrius / Schneider Livia / GM / Havells Crabtree), with modular plates and mounting boxes. Material shall be of approved brand or equivalent approved by Engineer-in-Charge. 22 Installation: Conduit routing, pulling & laying of wires, fixing boxes, switch & socket fixing, terminations, ferruling, earthing connection at point; including testing & commissioning of points (insulation/continuity) 23 Supply and fixing of Coat hooks / robe hooks (stainless) — supply & fixing of 2-hook stainless robe/coat hook set. - Two hooks per door/near entrance; SS finish; fixing with screws & plugs. 24 Supply and fixing of CPVC pipe 32 mm dia (supply) — ISI/approved CPVC pipe, per meter supply - inclusive of all fittings such as elbows, tees, unions, couplers, sockets, angle valves, stop valves, bib taps, outlet taps (chrome plated), pipe support and all fittings complete 25 Providing and fixing CPVC supply pipe (32 mm dia) for inlet lines: Concealed / open fixing on walls, floors or ceilings with CPVC fittings (elbows, tees, unions, reducers, bends, clamps, supports @1.5 m intervals), testing for leakage at 10 kg/cm² and flushing complete. Lines connect UG tank → booster pump → 500 L & 2000 L tanks and other locations as required. Material should be of approved brand by engineer in-charge. 26 Main circuit connection from DB to sub-circuit — Supplying and laying 3-core × 2.5 sq.mm FRLS copper wire in 25 mm PVC heavy-duty conduit (ISI-marked), with saddles and fittings, from main DB to lighting/exhaust/hand dryer circuit - inlcusive of Earthing & continuity connection — Providing 2-core × 2.5 sq.mm green FRLS copper wire from DB to all metallic fixtures (fans, lights, hand dryer), complete with earthing links, screws, and testing for continuity as per IS:3043. 27 Polymer-modified cementitious waterproof coating over floor and 300 mm skirting as per direction of engineer in-charge 28 Repair of loose plaster, cracks, and honeycombs: Raking out weak mortar and repairing surface defects with cement mortar 1:3 (1 cement : 3 coarse sand); applying bonding coat and finishing smooth; curing for minimum 48 hours. (including arrangement for water) 29 Repairs to plaster 12–20 mm thick in patches under 2.5 sqm using 1:4 mortar, cutting, raking joints and finishing smooth. 30 Suction & Delivery GI/HDPE Pipe with Fittings (50 mm dia): Supply, cutting, threading, jointing, laying and supporting suction (≈10 m) & delivery (≈15 m) pipes from UG tank to rising main including bends, elbows, reducers, flanges, painting with red oxide primer and two coats enamel. Material should be of approved brand by engineer in-charge. 31 Fixing, connection to point wiring, testing, commissioning, leveling and final cleaning per unit (complete installation and testing as per instruction of engineer in-charge) 32 Towel rail / ring (stainless steel) — supply & fixing of SS towel rail / ring (chrome finish), heavy duty brackets and plugs. - SS 304 finish; mounting on tile with rubber grommet. 33 Supply of materials for point wiring — FRLS PVC insulated copper wire (Finolex / Polycab / RR Kabel / Havells / KEI), rigid PVC conduit & accessories (BEC / AKG / Precision / Pressfit), modular switch plates (Anchor / Schneider / Legrand / GM). Material shall be of approved brand/make from above list or equivalent as approved by Engineer-in-Charge. 34 Fixing, point wiring, balancing, testing & commissioning per fan (Installation & commissioning included) 35 SS dustbin (pedal / lid) — supply & fixing — stainless steel (SS 304), 12–15 L capacity, wall bracket or floor standing. - One dustbin per cluster; provide anti-corrosion polish & mounting. 36 Construction of Brick wall of 230 mm thick — providing & laying F.P.S. bricks in cement mortar up to 3.5 m height, as per directions of engineer in-charge 37 Glazed ceramic wall tiles up to 2.1 m height — supply & fixing in 1:4 cement mortar, pointing as per direction of engineer in-charge 38 Anti-skid ceramic floor tiles 300×300 mm — supply & fixing in 20 mm CM 1:4, jointing & grouting; . - (Tiles as per approved makes (Kajaria / Somany / Nitco / Johnson / Asian or equivalent as approved by engineer-incharge). Adhesive, joints & cutting included. 39 Point wiring for lighting/exhaust/hand dryer (6 points) — PVC conduit, FRLS Cu wire, modular switches, ceiling rose, termination, testing. 40 False ceiling — suspended grid (GI channels / hangers) with 595×595 mm PVC ceiling panels or equivalent PVC/GI panels, complete with edge trims and cut-outs for fixtures. For area ≈ 5.0 m². Approved makes: Armstrong / Gyproc / USG Boral (ceiling systems) or approved PVC panel. - Includes hangers, wires, screws, grilles & fixing; drop ~300 mm. 41 Relaying new tiles using 40% old tiles — double charge vitrified polished finish (600×600 mm). 42 Glass replacement in windows with 5 mm float glass panes, including removal of damaged panes, cleaning rebates, fixing with putty/clips and finishing. 43 Supply and fixing of LED fixtures (36W) (Philips / Wipro / Havells / Bajaj / Crompton) including drivers, mounting brackets and wiring accessories — per unit. Material shall be of approved brand or equivalent approved by Engineer-in-Charge. 44 Silicone sealant, making good & final cleaning (LS) — sealant at all junctions, touch-up paint, final cleaning & disinfection prior to handover. - Includes consumables and labour for final handover. 45 Disposal of silt, debris, and foreign matter: Collection, loading, and removal of all dirt, silt, sludge, and waste materials from tank and surroundings within 50 m lead as directed by Engineer-in-Charge. (includes loading/unloading labour, and tools) 46 Final washing, drying, and refilling for test: Rinsing with clean water twice, drying for 6 hours, and refilling tank partially to check for leakage or seepage. (include water and labour) 47 SS dustbin (small) + grab rail / grab bar (stainless steel) supply & fixing (accessibility requirement). - SS 304 48 Soap dispenser (wall mounted, stainless / ABS pump) — supply & fixing, refillable type, anti-vandal. - Installed at basin height; includes adhesive & screws, sealing. 49 Disinfection using bleaching powder solution: Preparing and applying fresh solution (0.5 g/litre concentration) of bleaching powder (30% available chlorine); brushing and spraying entire surface uniformly as per instuction of engineer in-charge 50 Pressure Gauge Assembly & Accessories: Bourdon-type 0–10 kg/cm² with isolation valve mounted on delivery line, including brass fittings, air-release valve (15 mm), reducers and testing. The material should be IS:3624 compliant. 51 Supply of 1200 mm ceiling fan (Bajaj / Usha / Crompton / Havells / Orient) with accessories (downrod upto 3 m length wherever required, canopy, capacitor) — per fan - Material shall be of approved brand or equivalent approved by Engineer-in-Charge. 52 Pumping out stagnated water and sludge removal: Dewatering the underground tank (approx. 5m × 3m × 2.5m) using 3–5 HP portable submersible pump; bailing out accumulated water, sludge, and silt; manual scooping of residues and transferring to containers for safe disposal within 50 m. (Includes dewatering pump operation and labour.) 53 Installation: wiring from distribution, fixing isolator & point, earthing, testing & commissioning per AC point (includes switchgear mounting) (final testing to be done) 54 Mirror (600×450 mm) supply & fixing — bevelled or framed as approved. - Mirror fixed to wall with concealed hangers & silicone seal. 55 Soap dispenser + towel ring + toilet roll holder — supply & fixing; chrome plated brass/ABS as approved. - Includes adhesives, screws & wall plugs. 56 Grab rails / handrail & signage / coat hook — additional small fittings & SS hardware. 57 aluminium ventilators — 3 no. powder-coated aluminium louvre ventilators (400×400 mm) with insect mesh; including frames, SS hinges, locksets & sealing. 58 Electrical wiring & lighting installation — Supply, installation and wiring of 6 nos. light / exhaust / switch points including modular switches, MCB protection, PVC concealed conduit (20 mm), copper FRLS wire (1.5 sq.mm), ceiling rose, junction box, and accessories. 59 LED light fittings — Supply & fixing of 3 nos. LED ceiling lights 18 W, surface / recess mounted type, with necessary wiring and testing. Approved makes: Havells / Crompton / Philips / Bajaj / Wipro. includes fixing accessories, ceiling cutting, and finishing. 60 Commissioning verification (included within installation): continuity, polarity, insulation tests; corrective adjustments and handing over (per DB) 61 Granite counter for basins (3 nos) — supply & fixing of granite top (approx. 1.8 m length × 0.5 m width total area ≈0.9 m²) with cutouts for 3 basins, edge polishing, pedestal support & fixing. 62 Scaffolding, lighting, safety & PPE for confined space: Providing ladder, safety harness, safety rope, blower fan for ventilation, hand gloves, boots, masks, and site supervision for labour working inside tank. 63 Exhaust fan installation — Supply, fixing and connection of 2 nos. 200 mm dia exhaust fans with louvre and PVC frame, including 1.5 sq.mm wire, 2-pole MCB, and mounting. Approved makes: Crompton / Havells / Bajaj / Almonard / Usha. Includes making opening in wall / false ceiling and making good. 64 Installation: excavation for earthing pit, supply & compaction of back-fill, connection to main earthing conductor, testing (earth resistance), backfilling & reinstatement ( includes labour, testing & reinstatement) 65 Supply of isolator, modular accessories, switches, enclosure/housing & associated materials per AC point (all standard materials required per AC power point and as per instructions of engineer in-charge) - Material shall be of approved brand or equivalent approved by Engineer-in-Charge. 66 Tools, consumables: Supply and use of wire brushes, buckets, cleaning agents, safety gear, and minor hand tools. 67 Cold water supply distribution — Supply & fixing CPVC pipes (32/25 mm main + 20 mm branches), fittings, tees, unions, clamps & supports up to fixtures; includes angle valves (brass) and bib taps. Approved makes: Astral / Finolex / Supreme / Havmor (pipes & fittings), Jaquar / Cera (valves). - Includes joints, supports, wall chases & making good. Pressure test to 10 kg/cm². 68 Providing and fixing factory-made solid-core PVC doors suitable for toilet applications, comprising 30 mm thick PVC shutters made from multi-chambered extruded rigid PVC sections with integral stiles and rails, filled with solid PVC core, termite-proof, moisture-resistant, and fire-retardant, including smooth matt/semi-gloss finish in approved shade. The door frame shall be of PVC hollow sections 50×47×2 mm, mitre-jointed and solvent-welded, fixed in position with stainless steel screws, fasteners, and polymer sealant. Shutters shall be hung on three stainless steel (SS 304) hinges, fitted with SS mortice lock with two keys, tower bolt, rubber gasket/edge seal, door stopper, and necessary hardware. All joints shall be solvent welded, sealed watertight, and finished smooth. Size - 0.75 m × 2.00 m (clear opening) with outward swing and 20 mm bottom clearance from finished floor level. 69 Ventilation & lighting — Supply & fixing of 1 no. exhaust fan (200–250 mm), 1 no. LED ceiling light (18 W), wiring from nearest DB up to 5 m including modular switch & connection. Approved makes: Crompton / Havells / Philips / Bajaj or equivalent make. - Includes mounting, short conduit & testing. 70 Providing & fixing glazed wooden doors / shutters (30 mm thick wood) with 4 mm float glass panes, ISI MS pressed butt hinges & fittings, polished finish. 71 Provision & fixing of factory-made PVC door (30 mm thick solid-core) — supply, frame, SS hinges (3 nos.), mortice lockset with 2 keys, tower bolt, rubber gasket/seal, setting & making good. Standard size assumed 900×2100 mm. 72 Urinal partitions — supply & fixing (granite / high-density PVC panel) — panel size each 0.60 m × 1.20 m = 0.72 sqm; supply, template cutting, SS clamp supports, edge polishing, grout/sealant, and fixing in masonry opening. Qty = 5 nos (total 3.6 sqm). Approved: granite local / Bharat / Johnson or PVC from approved make. 73 Cleaning internal surfaces with wire and coconut brushes: thorough scrubbing and cleaning of walls, ceiling, and floor surfaces to remove algae, scales, and microbial growth; washing with clean water under pressure; collecting and removing sludge. (Complete surface cleaning up to 4–5 m tank depth). 74 Valves & Fittings Set: Includes 1 no. 50 mm NRV, 2 nos. 50 mm gate valves, 1 no. 50 mm foot valve with strainer, and all gaskets, nuts, bolts & washers; installation and testing complete as per IS:778 & IS:13095. 75 Main Entry Door (PVC solid core, 30 mm thick) with SS hinges, lockset, tower bolt, rubber seal, aluminium threshold – size 1.0×2.1 m complete with frame of approved brand and direction of engineer in-charge. - All doors shall be installed true to plumb, tested for smooth operation, and properly sealed to prevent ingress of moisture. Approved makes: Syntex / Wintech / Greenply / Rajshri or equivalent as approved by Engineer-in-Charge. 76 Supply of earthing materials per set: opper plate 600×600×3 mm (IS 3043) / Copper strip 25×3 mm (Havells / Ravin / CCI / Polycab / JEF), GI pipe for electrode, salt/charcoal back-fill, GI clamp, copper conductor to DB etc. (all materials required for earthing set complete and brand as approved by Engineer in-charge) 77 CP fittings, valves & accessories — bib cocks, angle valves, bottle traps, stop cocks, etc. (supply & fixing, leak test). 78 Supply, installation & connection of PVC Water Storage Tank (500 L): ISI-marked rotational moulded tank (Sintex/Plasto or approved), cylindrical vertical type with closed top; inlet, outlet, overflow & drain arrangements with ball valve; mounted on steel/concrete pedestal; connected to SA’s chamber toilet via 25 mm CPVC pipe; testing & disinfection complete. Material shall be of approved brand/make from above list or equivalent as approved by Engineer-in-Charge. 79 Minor Civil & Finishing Works: Includes repairing of disturbed plaster, floor making, cutting & sealing pipe openings, applying waterproof sealant at pipe entries, touch-up paint and cleanup of site along with Testing, Commissioning & Trial Run: Includes hydraulic testing of suction and delivery line, electrical testing for insulation resistance, earthing continuity, 48-hour trial run with load, demonstration to departmental staff, and submission of test report and warranty documents (minimum 1-year) 80 Foundation & Base Plate: MS base frame (10 mm thick) with foundation bolts and vibration pads, anchored on RCC pedestal (1.2 m × 0.6 m × 0.3 m), including painting and finishing around base. 81 Installation of DBs: Mounting on wall/stand, internal connections, earthing, MCB ferruling, interconnection to main incomer cable and proper labeling; testing for tightness and operation, labeling and dressing (including functional checks) 82 Sub-MCB protection & labeling — Supply, fixing & wiring of 6-way SPN MCB box (sheet steel, IP-65, powder-coated) with 32A incomer MCB and 6 outgoing circuits (6A–10A rating). Includes ferruling, labeling, and load marking. Approved makes: Legrand / Schneider / Siemens / Havells / L&T. (including plaster and paint patch work repair) 83 Sub-DB / MCB box & final connection — 6-way SPN with 32A incomer, ferruling, labelling & earthing. 84 Soil & waste discharge and septic tie-in — UPVC/SWR soil pipe 110 mm from pan to septic tank including inspection chamber connection, excavation (small), bedding, socket joints, gradient formation, backfill & making good. (Includes connection to existing septic tank / inspection chamber and leak test.) 85 CP fittings, valves, and accessories – including bib cocks, angle valves, stop cocks, health faucets, bottle traps, wall flange, and all required brass fittings. Approved makes: Jaquar / Kohler / Hindware / Parryware. (Complete with fixing, polishing, sealing and leak testing of all joints.) 86 Control Switch & Protection Panel: Wall-mounted IP-55 rated control box with ON/OFF selector, indicator lamps, thermal overload relay, voltmeter, ammeter, digital hour meter, and labeling. Material should be of approved brand by engineer in-charge. 87 Electrical Cabling & Panel Connection: Supply and lay 3-core × 6 sq.mm Cu flexible cable from nearest panel to starter, with MCB (32 A), DOL/Star-Delta starter, glands, lugs & terminations; approx. 15 m. Includes cable, switchgear, and terminations 88 Supply of DB enclosures and components — powder-coated metallic SPN/TPN type (MDS / Legrand / L&T / Schneider / Siemens), with neutral link, earth bar, incoming MCCB/MCB and outgoing MCBs (10 kA, C-curve). Material shall be of approved make as above or equivalent approved by Engineer-in-Charge. 89 Urinals with partitions – 5 nos. (wall hung type, vitreous china, with CP spreader, flush valve, waste pipe, trap and divider partitions in granite or FRP). Approved makes: Parryware / Hindware / Kohler / Jaquar / Cera. (Includes fixing with CP screws, sealant, flushing connections and making good.) 90 Basins with CP single lever mixer & bottle traps — 3 nos (counter / pedestal as required); supply & fixing. 91 Wash basins with CP fittings – 3 nos. (pedestal/half pedestal type with single lever pillar cock, bottle trap, waste coupling, brackets and all accessories). Approved makes: Jaquar / Kohler / Parryware / Hindware / Cera. (Includes water supply and waste connection, proper leveling, testing and polishing of granite counter if applicable.) 92 Providing & fixing MS rungs (20 mm dia) in underground RCC water tank at 300 mm c/c (approx. 9 rungs) and providing RCC manhole cover (M20) 1.2 m² × 100 mm thick with MS frame, hinges, locking arrangement, finishing and all incidental works, testing & curing 93 Hand dryer installation — Supply & fixing of 1 no. automatic hand dryer (1200–1600 W, IP44 rated) complete with wall plug, electrical connection and testing. Approved makes: Dyson / Crompton / Bobrick / Mitsubishi / Havells. (Includes switch plate, MCB, testing & demonstration.) 94 Laying, termination, testing & commissioning of above power cable with necessary accessories, GI saddles, trenching/ducting, tagging & identification, complete. (4 runs × 25 m = 100 Rmt) 95 Supply, installation & connection of PVC Water Storage Tank (2000 L): ISI-marked triple-layer with all fittings (inlet, outlet, overflow, drain cock, valves & supports), plumbing connections to staff toilets, testing and disinfection complete as per manufacturer’s recommendations and Engineer-in-Charge. Material shall be of approved brand/make from above list or equivalent as approved by Engineer-in-Charge. 96 Re-fabrication of main gate (raising height from 1.2 m to 2.1 m; width 3.75 m) including welding, repairs, alignment, priming & painting and supply/fixing of necessary fittings, complete (measured as one job). 97 Supply & fixing of sanitary fixtures (EWC dual-flush + WC seat, 1 urinal) — vitreous china, wall/floor mounted as applicable; includes seat, cistern, flush fittings, urinal trap. Approved makes: Parryware / Hindware / Cera / Jaquar / Kohler. - Supply, transport, setting, sealing & testing; warranty documents. 98 Supply of power cables (AL / Cu) (Polycab / KEI / Havells / Finolex / RR Kabel) & accessories (copper/aluminium cable, glands, lugs, saddles) — supply portion includes Supply of 1.1 kV grade 3½-core 25 sq mm aluminium armoured PVC insulated power cable with glands, lugs & saddles, complete. (4 runs × 25 m = 100 Rmt)- Material shall be of approved brand or equivalent approved by Engineer-in-Charge. 99 SITC of Centrifugal Monoblock Pump (4–5 HP, 3-phase): ISI-marked horizontal end-suction type; delivery head 45–55 m; discharge 300–400 LPM; CI body, bronze impeller, SS shaft, mechanical seal, flanged connections. Make: Kirloskar / Crompton / KSB / Texmo / Lubi. Material shall be of approved brand/make from above list or equivalent as approved by Engineer-in-Charge.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 5
25.
Defence #10335809 Price Bid
Tender For Supply And Construction Of Op Wks Asset Semi Ug Fdc; 1 Construction Material 1.01 Cement 43 Grade OPC packed in HDPE bag each 50 kg wt Conform to IS 8112-1989 (Make: Birla Gold/Ambuja/ Ultratech/ACC /JK/ Dalmia). 1.02 Coarse Sand free from vegetation 1.03 Coarse aggregate 20mm graded 1.04 Coarse aggregate 40mm graded 1.05 Coarse Aggregate 63-90 mm graded 1.06 Admixture.(Make Pedilite/Fevicol/Quick Fix) 1.07 AAC Blocks of size 600x200x150mm (Make:Brikolite/NCL/Nucon) 1.08 AAC Blocks of size 600x100x150mm (Make:Brikolite/NCL/Nucon) 1.09 Quick setting Compound (Make:- Pidilite/Fevicol/Quick Fix) 1.1 Mild Steel Bars of size 8 mm dia Conform to IS 432 (Part 1) 1982 (TMT Bar) (Make- TATA/ SAIL/ JSW ) 1.11 Mild Steel Bars of size 10mm dia Conform to IS 432 (Part 1) 1982 (TMT Bar) (Make- TATA/ SAIL/ JSW ) 1.12 Mild Steel Bars of size 12mm dia Conform to IS 432 (Part 1) 1982 (TMT Bar) (Make- TATA/ SAIL/ JSW ) 1.13 Mild Steel Bars of size 16 mm dia Conform to IS 432 (Part 1) 1982 (TMT Bar) (Make- TATA/ SAIL/ JSW ) 1.14 Mild Steel Bars of size 20 mm dia Conform to IS 432 (Part 1) 1982 (TMT Bar) (Make- TATA/ SAIL/ JSW ) 1.15 MS Binding wire : Make (TATA/ SAIL/ JSW) 1.16 Wooden plank for shuttering II class wood of size 3.0 x0.3 x0.026 m 1.17 Wooden Scantling various size 1.18 Steel props of size 2 mtr long, 80 mm dia, adjustable up to 4 mtr height and as directed 1.19 Water Proofing Compound Conform to IS 2645-2003. Make : Pidilite/ Dr Fixit/Fevicol 1.2 Birla white wall care putty (water resistant white cement) ( Make : Berger/Asian/Nerolac) 1.21 Oil bound distemper (washable Quality) of proprietary brand of ( Make : Berger/Asian/Nerolac) 1.22 Acrylic emulsion paint 1.23 Synthetic enamelied paint any colour as directed conforming to IS 5-2004 ( Make : Berger/Asian/Nerolac) 1.24 Painting brush 4 (ISI Marked) 1.25 Nails various sizes 1.26 Steel door frame of angle iron 65x65x6mm and shutter 2 mm thick including all fittings overall size 1.00x2.00x2.10mtr double shutter (Make: TATA /SAIL/JSW) 1.27 Aluminium door with frame of section weight not less than 1.5kg/per RM and shutter cosisting of 5mm thick glass of size 1500 mm x 2100 double shutter incl all fittings and as directed. (Make: Jindal/Hindalco ) 1.28 Aluminium door with frame of section weight not less than 1.5kg/per RM and shutter cosisting of 5mm thick glass of size 1200 mm x 2100 double shutter incl all fittings and as directed. (Make: Jindal/Hindalco ) 1.29 Aluminium window with frame of section weight not less than 1.5kg/per RM and shutter 5mm thick of size 1200 mm x 900 double shutter incl all fittings and as directed. (Make: Jindal/Hindalco 1.30 Aluminium ventilator three track frame of section weight not less than 1.5kg/per RM and of size 1200 mm x 600 fixed type with glass (4mm thick) and 0.45mm dia SS wire mesh incl all fittings and as directed. (Make: Jindal/Hindalco 1.31 Factory made solid panel PVC door shutter 800 x 2100 mm 30 mm thick (style) consisting of frame 30 mm thick (style) consisting of frame rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing and incl Solid PVC Door Frame of size 50mm x47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per Drawing. Door shall be include of 2 nos 150 mm Al handles,2 nos 150 mm tower bolt, 01 No Sliding door bolt and 03 Nos 100 mm Al butt hinges 1.32 Kota Stone of size 600 mm x 600 mm for floor and skirting thickness between 20 to 22 mm thick 1.33 Non skid Ceramic tiles of size 300mmx300mm on the floor. Minimum thickness shall be between 6-8 mm tiles of Make: Johnson/ Kajaria/ Orient (1st quality) conforming to IS : 15622-2006) 1.34 Glazed ceramic tiles of size 300x450 mm thickness between 7 to 8 mm Make: Johnson/ Kajaria/ Orient (1st quality) conforming to IS : 15622-2006) 1.35 White cement conform to IS-8042/1989 (Make : ACC/ Birla White/ Ambuja). 1.36 APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm) land on primed surface by forced application complete all as specified. 1.37 Priming surfaces and applying bitumen as a primer in base of APP membrane 1.38 Acoustic panels in using in a wall and celings with using a grid for sound absorbing fabric wrapped boards designed to control echo and reverberation in a room. 2 MS frame work for roof trusses, purlin, rafter and MS plate etc all as directed (Make : TATA/SAIL/JSW) :- 2.01 (a) MS RHS of size 122X61X4.5 2.02 (b) MS RHS of size 80X40X3.2 2.03 (c) MS RHS of size 63.5x38x3.65mm 2.04 (d) MS RHS of size 90X40x3.20 2.05 (e) MS RHS of size 50x 25.4x3.25 mm 2.06 (f) MS FI 50x 6 mm th 2.07 (g) MS Plate of size 8mm thick 2.08 (h) MS Plate of size 6mm thick 2.09 MS Nuts and bolts of length 100mm fully thread suitable for 10 mm dia nuts including two numbers of washers and 25mm of shank and two nos of washers 3 mm thick complete all as directed. 2.1 Pre painted galvatume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick an colour having a tensile strength 550 Mpa of size 10x3. (Make-Uniix/Jindal mectec or Eqv Brand ) 2.11 Pre painted galvatume aluminium zinc coating GI based plain steel sheet 0.50 mm thick an colour having a tensile strength 550 Mpa(Make-Uniix/Jindal mectec or Eqv Brand) 2.12 Self taping steel screw half thread with rawl plug of 1 1/2 size (ISI Marked) (100 Nos/Pkt) 3 Construction Mtrl For Retaining Wall (72.00 Mtr) + 8x3Mtr x 4Mtr = 09 Nos. 3.01 Cement 43 Grade OPC packed in HDPE bag each 50 kg wt Conform to IS 8112-1989 (Make: Birla Gold/Ambuja/ Ultratech/ACC/JK/Dalmia). 3.02 Coarse Sand free from vegetation 3.03 Coarse aggregate 40mm graded 3.04 Stone Boulder 9 to 12 3.05 PVC Pipe 75 mm dia 3 Mtr Long Make:Prince/Finolex/Supreme or Eqvlt 4 Construction Mtrl For Toe Wall (60.00 Mtr) + 8x2 Mtr x 2 Mtr Ht = 7.50 Nos. 4.01 Cement 43 Grade OPC packed in HDPE bag each 50 kg wt Conform to IS 8112-1989 (Make: Birla Gold/Ambuja/ Ultratech/ACC/JK/Dalmia). 4.02 Coarse Sand free from vegetation 4.03 Coarse aggregate 40mm graded 4.04 Stone Boulder 9 to 12 4.05 PVC Pipe 75 mm dia 3 Mtr Long Make:Prince/Finolex/Supreme or Eqvlt 5 B/R Items 5.01 Water Storage tank triple layer 1000 Ltrs confirming to IS 12701-1996 (Make : Sintex /Ultrapure Aqua /Polywell) 5.02 Fabrication from Structural steel section for staging of water storage tank made of capacity 500/1000 ltrs made out of MS angle iron frame of size 50 x 50 x 6mm thick with height of 4.0 mtr above ground level and 0.6 mtr below ground level embeded in PCC 1:2:4 of 20mm graded agg below the ground level. The inner bracing of staging should be fixed with 40 X 40 x 5mm MS angle iron fixed with suitable size MS plate of 3mm thick and at top of the staging 1.2m x 1.2m x 3mm for placing the PVC tank and anchored with MS angle iron frame of size 25 x 25 x 5 mm thick with ht of 0.80 mtr from the bottom of Base plate of tank incl ladder complete with two coats of metal painting over one coat of primer (Make of angle iron : TATA/SAIL/JSW) 5.03 WC European type model 2008 EWC and combi flush PVC flushing cistern of 10 Ltr capacity. Make:- Cera or equivalent models in Hindware / Parryware 5.04 IWC of vitreous china squatting Pan Orissa pattern of size 580mmx440mm, dark coloured with P or S trap (Make: Parryware/Hindware/Cera complete in all respects. 5.05 Looking Mirror of selected quality frameless of size 600X450x5mm (Make : Prayag/Saint Gobain/ Modigaurd) 5.06 Chromium plated Toilet Paper Holder with flap (Make:-Ess Ess/Jaquar/ Johnson Suisse) 5.07 Brass Chromium plated towel Rail 600 mm Long 20 mm dia with cloth hooks min 04 Nos (Make:-Ess Ess/Prayag/ Johnson Suisse) 5.08 Chromium plated Piller cock swan neck with aerator and butter fly handle weight not less then 450 gm (Make:-Ess Ess/Prayag/ Johnson Suisse) 5.09 Stop Cock angular type Chromium plated Brass 15 mm weight not less then 330 gm (Make:-Ess Ess/Prayag/ Johnson Suisse) 5.1 Stop Cock T Type Chromium plated Brass 15 mm weight not less then 330 gm (Make:-Ess Ess/Prayag/ Johnson Suisse) 5.11 Brass Chromium plated Shower rose 100 mm dia with bend (Make:-Ess Ess/Prayag/ Johnson Suisse) 5.12 Bib Cock long spout brass chromium plated 15 mm weight not less then 330 gm (Make:-Ess Ess/Prayag/ Johnson Suisse) 5.13 Health faucet set chromium plated brass length of flexible pipe not less than 1.2 mtr (Make:-Ess Ess/Prayag/ Johnson Suisse) 5.14 PVC Connection 45 cm long 15 mm (Make:-Supreme/Johnson Suisse/Famingo). 5.15 Peg set of six fitted with galvanised screws along the internal surface of the walls in the rooms (Make:-Ess Ess/Prayag/ Johnson Suisse) 5.16 Corner Sheet Glass Shelf with two shelf assembly consisting of 5.5mm thick sheet glass shelf with cromium plated brass bracket guard and railing.( Make-Supreme/Neelkamal/Prayag) 5.17 Soap Dish SS, flat back complete with screw (Make:-Ess Ess/Prayag/ Johnson Suisse) 5.18 PPR Pipe 32 mm dia (Make:- SFMC/Finolex/Supreme) 5.19 PPR Socket 32 mm (Make:- SFMC/Finolex/Supreme) 5.2 PPR Elbow 90 degree 32 mm (Make:- SFMC/Finolex/Supreme) 5.21 PPR Reducer T 32-20-32 mm dia (Make : SFMC/Finolex/Supreme) 5.22 PPR Plain T 32 mm (Make:- SFMC/Finolex/Supreme) 5.23 PPR Union 32 mm (Make:- SFMC/Finolex/Supreme) 5.24 Tank Connector 32 mm (Make:- SFMC/Finolex/Supreme) 5.25 PVC Wall Clamp 32 MM (Make:- SFMC/Finolex/Supreme) 5.26 Gate Valve 32 mm (Make:- SFMC/Finolex/Supreme) 5.27 PPR Pipe 20 mm Dia (Make : SFMC/FINOLEX/SUPREME) 5.28 PPR Elbow 20 mm (Make:- SFMC/Finolex/Supreme) 5.29 PPR Female thread Elbow 90 degree 20 mm dia (Make : SFMC/FINOLEX/SUPREME) 5.3 PPR female thread T 20 mm dia (Make:- SFMC/Finolex/Supreme) 5.31 PVC wall clamp 20 mm dia (Make : SFMC/FINOLEX/SUPREME) 5.32 Float Valve 20 mm (Make:- SFMC/Finolex/Supreme) 5.33 M Seal 150 GM Pkt (Make:- Pidilite/Fevicol/M Seal) 5.34 Taflon Tape Roll (ISI Marked) (Make :- Supreme/Omega/Asbestos) 5.35 Solvent Cement 150 GM Tube (Make:- Finolex/Fit Well/Jindal) 5.36 PVC Waste Pipe 32 mm and 1m long (Make:-Supreme/Johnson Suisse/Famingo). 5.37 Chromium plated Waste coupling 32 mm dia (Make:-Supreme/Johnson Suisse /Famingo). 5.38 CP grating 100 mm dia (Make:-Ess Ess/Prayag/ Johnson Suisse) 5.39 PVC Pipe 110 mm dia 3 mtr long (Make :- Prince/Finolex/Supreme ) 5.4 PVC Socket 110 mm dia (Make :- Prince/Finolex/Supreme ) 5.41 PVC Bend110 mm dia(Make :- Prince/Finolex/Supreme ) 5.42 S Trap vitreous china (Make :- Hindware / Parryware/Cera ) 5.43 PVC Pipe 75 mm dia each 3 mtr length (Make :Prince/Finolex/Supreme ) 5.44 PVC Socket 75 mm dia (Make :- Prince/Finolex/Supreme ) 5.45 PVC Bend 75 mm dia (Make :- Prince/Finolex/Supreme ) 5.46 Curtain Arrangement Drapery and rod made of 25 mm dia and 1600 mm long, pre coated MS pipe with fancy type ends. Suitable fixing arrangement for the curtain rod, shall be made and supplied to hold the curtain rods alongwith fixing arrangement complete. (ISI Marked) 5.47 PVC Air Pipe 32 mm dia (Make : SFMC/Finolex/Supreme) 5.48 White Cement confirming to IS 8042/1989 (Make: ACC/Birla White /Ambuja 5.49 Vitreous china Wash hand basin white of size 450mmx300mm with vitreous china pedestal of suitable size . Make:- Cera or equivalent model No 1009 /Hindware/Parryware. 5.5 PPR Reducer Elbow 32mm x 20mm dia (Make : SFMC/FINOLEX/SUPREME) 5.51 Brass CP Wall Mixer for mixing hot and cold water screwed down for PPR pipe of dia 20mm (Make : Cera / Hindware / Parryware) 5.52 Brass CP Jet water spray for EWC. (Make- Ess Ess/PRAYAG/JOHNSON SUISSE) 5.53 Vitreous China urinals, full stall type (back or corner wall type), complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe. (Exclusive of fixing supply pipe to flushing cistern complete all as specified and directed. 5.54 Plastic dustbin of capacity 40 ltrs (Make : NEELKAMAL/CELLO/SUPREME) 6 Constr Mtrl for Drain & Sump 6.01 Cement OPC 43 Grade packed in HDPE bag each 50 Kg wt conforming to IS 8112 - 1989 (Make:-Birla Gold/Ambuja/ Ultratech/ACC/JK/ Dalmia) 6.02 Coarse sand free from vegetation 6.03 Coarse Aggregate 20mm graded 6.04 Coarse Aggregate 40mm graded 6.05 Hardcore 63 to 90mm 6.06 AAC Blocks 600x200x150 6.07 Mild Steel Bars of size 10mm dia conforming to IS 432 (Part I) 1982 (Make : TATA / SAIL /JSW) 6.08 Three phase 1.2 HP Monoblock pump 430 Volt complete with and incl 3 Mtr length required size flexible suction pipe, foot valve and connected accessories complete all as specified and directed (incl tasting x comminssining) 7 Septic Tank = 02 Nos Construction Material 7.01 Cement 43 Grade OPC packed in HDPE bag each 50 kg wt Conform to IS 8112-1989 (Make: Birla Gold/Ambuja/ Ultratech/ACC /JK/ Dalmia). 7.02 Coarse Sand free from vegetation 7.03 Coarse aggregate 20mm graded 7.04 Coarse aggregate 40mm graded 7.05 Bricks sub class B 7.06 Quick setting Compound (Make:- Pidilite/Fevicol/Quick Fix) 7.07 Mild Steel Bars of size 8 mm dia Conform to IS 432 (Part 1) 1982 (TMT Bar) (Make- TATA/ SAIL/ JSW ) 7.08 Mild Steel Bars of size 10mm dia Conform to IS 432 (Part 1) 1982 (TMT Bar) (Make- TATA/ SAIL/ JSW ) 7.09 MS Binding wire : Make (TATA/ SAIL/ JSW) 7.1 Wooden plank for shuttering II class wood of size 3.0 x0.3 x0.026 m 7.11 Wooden Scantling various size 7.12 Steel props of size 2 mtr long, 80 mm dia, adjustable up to 4 mtr height and as directed 7.13 Water Proofing Compound Conform to IS 2645-2003. Make : Pidilite/ Dr Fixit/Fevicol 7.14 PVC Pipe 110 mm dia 3 mtr long (Make :- Prince/Finolex/Supreme ) 7.15 PVC Socket 110 mm (Make :- Prince/Finolex/Supreme ) 7.16 PVC T 110 mm dia (Make :- Prince/Finolex/ Supreme ) 8 Soak Well = 02 Nos 8.01 Cement 43 Grade OPC packed in HDPE bag each 50 kg wt Conform to IS 8112-1989 (Make: Birla Gold/Ambuja/ Ultratech/ACC /JK/ Dalmia). 8.02 Coarse Sand free from vegetation 8.03 Coarse aggregate 20mm graded 8.04 Coarse aggregate 40mm graded 8.05 Bricks sub class B 8.06 Brick Bats 8.07 Quick setting Compound (Make:- Pidilite/Fevicol/Quick Fix) 8.08 Mild Steel Bars of size 8 mm dia Conform to IS 432 (Part 1) 1982 (TMT Bar) (Make- TATA/ SAIL/ JSW ) 8.09 Mild Steel Bars of size 5 mm dia Conform to IS 432 (Part 1) 1982 (TMT Bar) (Make- TATA/ SAIL/ JSW ) 8.1 Mild Steel Bars of size 10mm dia Conform to IS 432 (Part 1) 1982 (TMT Bar) (Make- TATA/ SAIL/ JSW ) 8.11 MS Binding wire : Make (TATA/ SAIL/ JSW) 8.12 Coarse Aggregate 63-90 mm graded 8.13 Cast iron Manhole covers exc 5 Kg weight each on soakage well grade FG 150 all as specified and directed. 8.14 PVC Pipe 75 mm dia 3 mtr long (Make :- Prince/Finolex/Supreme ) 8.15 PVC Cowl 75 mm dia (Make : PRINCE/FINOLEX/SUPREME) 8.16 MS Binding Wire 9 E&M Items 9.01 Distribution box 8 way double door SPN 240 volts copper bus bar and neutral link earthing stud Conform to IS-13032 & IS – 8623 double door type. (Make : Havells/ Legrand/L&T). 9.02 MCB SPN 240 Volts 32 Amps (Make : Havells/L&T/Standard). 9.03 MCB SP 240 Volts 6 to 32 Amps (Make : Havells/L&T/Standard). 9.04 PVC tape 19mm wide 5m long (Make Steel grip/ Anchor/ Kinjal). 9.05 Cable PVC insulated electric cable(heavy duty) 1100 volts grade multi standerd copper conductor of size 1.5 sqmm single core (FRLSH) conforming to IS 1554(part -1) 1988 (Make : Havells /Finolex/ Paragon). 9.06 Cable PVC insulated electric cable(heavy duty) 1100 volts grade multi standerd copper conductor of size 2.5 sqmm single core (FRLSH) conforming to IS 1554(part -1) 1988 (Make : Havells /Finolex/ Paragon). 9.07 Cable PVC insulated electric cable(heavy duty) 1100 volts grade multi standerd copper conductor of size 4 sqmm single core (FRLSH) conforming to IS 1554(part -1) 1988 (Make : Havells /Finolex/ Paragon). 9.08 PVC conduit pipe 25mm dia Medium Grade(Make: Presto/ Polycab/ Finolex). 9.09 PVC conduit pipe 19mm dia Medium Grade (Snow white) (Make: Presto/ Polycab/ Finolex). 9.1 Switch Modular type 5A 230V flush type one way (Snow white) (Make-Legrand/ABB/Havells Crab Tree). 9.11 LED Tube light fittings rechargeable 18/20 W 230V box type 4 feet with CRCA body Pre coated white and Prewired for LED tube complete.(Make:Havells/Bajaj/ Philips/Crompton). 9.12 Screw 6x19mm ISI Marked (200 screw per pkt). 9.13 PVC Modular switch board 3 way complete with and incl sunken box, cover plate with frame. Make-Legrand/ABB/Havells Crab Tree. 9.14 PVC Modular switch board 4 way complete with and incl sunken box, cover plate with frame. Make-Legrand/ABB/Havells Crab Tree. 9.15 PVC Modular switch board 6 way complete with and incl sunken box, cover plate with frame. Make-Legrand/ABB/Havells Crab Tree. 9.16 PVC Modular switch board 8 way complete with and incl sunken box, cover plate with frame. Make-Legrand/ABB/Havells Crab Tree. 9.17 PVC switch board (Snow white) of size 8x10 for main switch/ DB Make : Supreme/ Polycab/ Finolex. 9.18 Switch Modular type 15A 230V flush type one way (Snow white) (Make-Legrand/ABB/Havells Crab Tree). 9.19 Socket Modular type 15A 230V flush type one way (Snow white) (Make-Legrand/ABB/Havells Crab Tree). 9.2 Socket Modular type 5A 230V flush type one way (Snow white) (Make-Legrand/ABB/Havells Crab Tree). 9.21 Cable XLPE insulated aluminium conductor, 1100V grade heavy duty UG Cable of size 25 Sqmm 4 core (Make Havells/ Finolex/ Plaza). 9.22 Ceiling rose three terminal (Snow white) (Make-Anchor/ SSK/ CONA). 9.23 LED Flood light fittings high pressure die cast aluminium 50 watt with including nuts and Bolts complete. Make-Havells/Bajaj/ Philips/ Crompton). 9.24 PVC flexible wire copper conductor multi strandard 0.0016/76 (Make - Havells/ Finolex/Plaza). 9.25 PVC flexible conduit pipe 19 mm dia Make : Supreme/ Finolex /Polycab. 9.26 PVC round/ square block Make : Supreme/ Finolex /Polycab. 9.27 Plastic body fresh air fan with louvers shutter of 200mm sweep model brisk air of Crompton Greaves or equivalent models in Havells/ Bajaj/ Khaitan. 9.28 Fire exitingusher of 1Kg capacity of dry powder type Conform to IS-13849 alongwith accessories (Make-Cease Fire/Omex/Alfa Fire). 9.29 PVC L bend and T junction joint for PVC casing and capping Conform to IS-3419 (Part-III) Make : Supreme/ Polycab/ Finolex. 9.3 Distribution box TPN 4 way double door with 200 Amp copper bus bar and neutral link earthing stud. (Make : Havells/ Legrand/L&T). 9.31 Isolator TPN 430 Volts 63 Amps (Make : Havells/L&T/Standard). 9.32 Cable PVC insulated electric cable(heavy duty) 1100 volts grade multi standerd copper conductor of size 10 sqmm single core (FRLS) conforming to IS 1554(part -1) 1988 (Make : Havells /Finolex/ Paragon). 9.33 MCCB TPN 100 Amp 25KA 430 volts complete with and incl sheet steel enclosure complete. (Make Legrand, L&T, Havells). 9.34 PVC Modular Blanking Plate 1 way. Make-Legrand/ABB/Havells Crab Tree. 9.35 Surface/ceiling mounted LED fitting 12/16 Watt compete with all accessories. Make: Havells/Philips/Crompton. 9.36 Aluminium Hydrolic Pop up boxe 3M for installation on desk or Floor for the use of cable management complete with all accessories. (Make Legrand, L&T, Havells) 9.37 LED ceiling light 36 watt complete with all accessories. Make: Havells/Philips/Crompton or of equivallent. 9.38 Wall mounted Fan 300mm sweep 230Volt prewired complete. Make: Havells/Bajaj/Crompton or of equivalent. 9.39 Supply, Installing, testing and commissioning of Heavy duty industrial grade Dehumidifer 0.2 Ton (15 LPD) single phase 230 Volt with all connected accessories with following specifications:- Type: vertical, Frame: GI section profile, Panel: Heavy Guage single skin/SS, Compressor: Auto shutoff, Colour: Bi-colour powder coated/mat, Ambient temperature: 5-50 degree Cente grade, Back suction front throw for larger area coverage one touch humidity setting and display, Temparature disply, inbuilt auto Defrost, inbuilt compressor protection, inbuilt Fuse and MCB prote, the unit is fully mobile, works independently without attendant, Compressor: Low power emerson complete all as directed. Make DUEX Industries system of series DEW-POINT or of equivalent. Note: (i) Contractor shall be take approval of the acceptance officer before procurement. 10 Earthing Items 10.01 Earthing Plate 600x600x6mm GI steel suitable for GI strip fittings, drilled with two nos holes for 6 mm dia near one side. 10.02 CI earth pit cover of size 300x300x6mm with angle iron of size 20x20x3mm thick with MS frame. 10.03 Funnel fitted with 20mm dia GI Pipe 1.5m long Make: Jindal/ Tata/ Kalinga. 10.04 GI Wire 4mm dia for earthing. 10.05 Charcoal. 10.06 Salt normal. 10.07 Air terminal single pointed aluminium rod 12mm dia and 300mm long. 10.08 Testing point terminal block made of gun metal & phosphorus bronze size 75x75x25mm drilled and screwed including 3 Nos 8mm dia 25mm long hexagonal head screw. 10.09 Aluminium strips 25x3mm . 10.1 Galvanised iron strip 32x6mm . 10.11 Funnel fitted with 20mm dia GI Pipe 1.5m long Make: Jindal/ Tata/ Kalinga. 10.12 Earthing Plate 600x600x6mm GI steel suitable for GI strip fittings, drilled with two nos holes for 6 mm dia near one side. 10.13 CI earth pit cover of size 300x300x6mm with angle of size 20x20x3mm thick with MS frame. 10.14 Insulating PVC block 75x75x30 mm with insulating clamp nut & bolt Make Presto/ Polycab/ Finolex. 10.15 GI pipe 40mm dia light grade (Make: Jindal/Tata/Kalinga) 10.16 Semi integrated Solar LED Street light set comprising of Solar LED light IP-65, 43W of min 4300 Lumens, 36Ah Lithium Battery, 165 Watt Solar panel, single arm Hexognal pole 6 Mtr long 70 mm dia at top and 135mm dia at bottom with 220x220x12mm base plate, complete with 1.5 sq mm 3 core multistranded copper conductor cable, foundation bolt, Solar Structure and all other connected aceessories. Make: Havells/Philips/Crompton/Bajaj or of equivalent. 10.17 Cement 43 Grade OPC packed in HDPE bag each 50 Kg wt conform to IS 8112 -1989 (Make : Birla Gold/Ambuja/Ultratech /JK /Dalmia/ACC 10.18 Coarse sand free from vegetation 10.19 Coarse aggregate 20mm graded 10.2 Supply, installation, testing and commissioning of 125 KVA, 03 phase 415 volts AC, 50 Hz, at 0.8 pf (laging) Four cylinder Silent Diesel run Genr Set as per CPCB-IV norms, Out door Service type comprising of Engine, with minium 150 BHP at 1500 RPM, coupled with alternator of same make mounted on a common base frame complete with and incl free standing floor mounted metal clad cubical type AMF control Panel (the thickness of sheet steel shall not be less than 1.6 mm for cold rolled steel and base plate shall not be less than 2 mm thickness), Fuel tank 230-300 Ltrs, 12 V Battery & leads as per OEM, Silencer-Residential, AVM pads, First fill of lube oil, Acoustic enclosure, sound proof canopy, self starter, cold start kit, standard set of tools and spares for maintence 24 Months and first fill of engine oil complete with all connected accessories (MCCB/MCB/Contactor/SMPS based Battery charger/internal wiring/Cable glands and lugs etc, with features for automatic shutdown in the event of a circular failure condition arising from low oil pressure, high coolant temperature, over speed etc & microprocessor based genset with the following under mentioned features & all as specified & as directed:- (a) Alphanumeric LCD display with LED backlight. (b) Operator interface (c) Suitable to provide a record of most recent fault conditions & fault history. (d) Complete alternator data viz, voltage ph-ph, ph-neutral, KVA, frequency etc.(e) Complete engine data viz, starting battery voltage, engine temp, engine running hours, engine oil pressure etc. (f) Control including provn of service adjustment & calibration of DG control functions. (A) GENR SET SPECIFICATIONS: PRIME MOVER RATING : 125 KVA/100KW. NO OF PHASES : 03. POWER FACTOR : 0.8 (LAG). (B) ENGINE SPECIFICATIONS: COOLING : WATER COOLED WITH RADIATOR AND FAN. ASPIRATION : TURBO-CHARGED-AFTER COOLED. RPM : 1500. GOVERNOR: ELECTRONIC TYPE. (C) ALTERNATOR SPECIFICATIONS: VOLTAGE: 415, RPM/FREQUENCY : 1500/50 HZ ENCLOSURE : IP 23, VOLTAGE REGULATION (MAX) : +/- 1% INSULATION CLASS : H CLASS.(D) Engine, Alternator,Battery and controller should be of same make. (E) Make: KIRLOSKAR/CUMMINS/VOLVO PENTA/MAHINDRA (Engine, Alternator and controller should be of same make).NOTE : 1) Anything missed out in the technical specifications but technically required for efficient working of DG set is deemed to be included in the quoted rates.2) The quoted rates for Genr Set shall be deemed to be inclusive of cold start kit, standard set of tools and spares for maintence 18 Months and first fill of engine oil & final successful acceptance test.3) The quoted rate shall be deemed to be inclusive of 12 hrs test run at site as specified in presence of rep of Accepting Officer, all testing arrangements/equipments resistive load including POL shall be made available by the contractor.4. Waranty : 24 Months from the date of commissioning/installing 10.21 MCB SPN 240 Volts 32 Amps (Make : Havells/ L&T/ Standard). 10.22 MCB SP 6 to 32 Amps (Make : Havells/ L&T/ Standard). 10.23 PVC tape 19mm wide 5 m long (Make : Steelgrip/Anchor/Kinjal). 10.24 On load Change over switch within sheet steel enclosure 300 Amps.4 pole. TPN confirming to IS 13947 (Part 3 ) 2607 (Make:- Hsvells/Standard/L&T) 10.25 Cable PVC insulated electric cables (heavy duty)1100 volts grade multi standerd copper conductor of size 1.5 sqmm single core (FRLS) confirming to IS 1554 (Part-I) 1988 complete with and incl PVC flexible conduit 15mm complete as directed by accepting officer (Make : Havells /Finolex/ Polycab). 10.26 Cable PVC insulated electric cables (heavy duty)1100 volts grade multi standerd copper conductor of size 1.5 sqmm single core (FRLS) confirming to IS 1554 (Part-I) 1988 complete with and incl PVC flexible conduit 15mm complete as directed by accepting officer (Make : Havells /Finolex/ Polycab). 10.27 Cable XLPE insualted screened PVC bedded, galvanised steel strip or wire armored electric power cable (heavy duty) 1100 volts grade with multi stranded aluminum conductor of size 150 Sqmm 3.5 core , FRLS, confirming to IS 7098 (part-1) 1998 (Make: Havens /Finolex /Polycab) 10.28 Switch Piano 5 Amp 230 Volts Flush type one way (snow white) (Make : Anchor/ SSK/Cona). 10.29 Switch socket combination (Snow white) multipurpose 2 in 1, 15A. 230V (Make- Anchor/ SSK/Cona) 10.3 LED Tube light fittings 18/20W 230V box type 4 feet with CRCA body Pre coated white and Prewired for LED tube complete (Make : Havells/Bajaj /Philips/ Crompton). 10.31 Screw full thread 6 x 19 mm ISI Marked, 200 Nos Pkt. 10.32 PVC switch board (snow white) size 7”x4” for sockets and switches (Make : Supreme/ Polycab/ Finolex). 10.33 Ceiling Rose three terminal (snow white) (Make : Anchor/ SSK/CONA). 10.34 PVC Round/Square Block (Make:- Polycab/Supreme/ Finolex). 10.35 Distribution box 4 way, double door SPN 240 volts copper bus bar and natural link earthing stud confirming to IS -13032 & IS-8623 double door type (Make: Havells/Legrand/L&T) 10.36 Service cable PVC insulated aluminium conductor, 1100 volt grade Heavy duty served with inner sheathing of PVC tap and overall PVC sheathed in service connection 06 Sqmm 2 core (Make : Havells/ Finolex/ Plaza). 11 EARTHING ITEMS 11.01 Earthing Plate 600x600x6mm GI steel suitable for GI strip fittings, drilled with two nos holes for 6 mm dia near one side. 11.02 CI earth pit cover of size 300x300x6mm with angle iron of size 20x20x3mm thick with MS frame. 11.03 Funnel fitted with 20mm dia GI Pipe 1.5m long Make Jindal/ Tata/ Kalinga) 11.04 Galvanized Iron strip 32 x 6mm 11.05 Charcoal 11.06 Salt Normal 12 CONSTR MTRL OF EARTHING PIT 12.01 Cement 43 Grade OPC packed in HDPE bag each 50 kg wt Conform to IS 8112-1989 (Make: Birla Gold/Ambuja/ Ultratech/ACC /JK/ Dalmia). 12.02 Coarse Sand free from vegetation 12.03 Coarse aggregate 20mm graded 12.04 Coarse aggregate 40mm graded 13 Gen Set with plinth & Shed 13.01 Cement 43 Grade OPC packed in HDPE bag each 50 kg wt Conforming to IS 8112-1989 (Make : Birla Gold/Ambuja/Ultratech/ ACC/JK/Dalmia) 13.02 Coarse Sand free from vegitation 13.03 Coarse aggregate 20mm graded 13.04 Coarse aggregate 40mm graded 13.05 Hard Core 40 to 63 mm graded 13.06 Stone for RR Masonary less than 6 13.07 Pre painted galvatume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick an colour having a tensile strength 550 Mpa of size 08x3. (Make-Uniix/Jindal mectec or Eqv Brand ) 13.08 MS Pipe med grade 50mm dia confirming to IS 1611-1998 : JINDAL/TATA/SAIL 13.09 Painting Brush 4 (ISI Marked) 13.1 Anti corrosive red oxide zinc chromate primer confirming to IS 5-2004 (Make : Berger/Asian/Nerolac) 13.11 Synthetic paint enamelled OG confirming to IS 5-2004 (Make: Beger/ Asian) 13.12 Thinner 13.13 Self driving scrw for PPGI sheet (100 Nos/Pkt) 13.14 Iron welding rod confirming to IS 814-2002 (ISI Marked) 3.15mm thick. (100 Nos/Pkt) 14 HARDSTANDING 400 SQM 14.01 Cement 43 Grade OPC packed in HDPE bag each 50 kg wt Conform to IS 8112-1989 (Make: Birla Gold/Ambuja/ Ultratech/ACC/JK/Dalmia/equivalent). 14.02 Coarse Sand free from vegetation 14.03 Coarse aggregate 20mm graded 14.04 Coarse aggregate 40mm graded 14.05 Hard core 40-63mm 14.06 80 mm thick coloured Interlocking precast paver block I shape and size confirming to IS 15658- 2006, grade M-40 of size 250mmx125mmx80mm 14.07 Wooden Scantling various sizes 14.08 Wooden planks for shuttering IInd class wood of size 3.0 x 0.30 x 0.026m 14.09 Road Delineator (type-fixed) Material-ABS, Shape-Ellipsoidal. Ht-751-800mm and base body 80mm diameter of Make-3M Dauk Eye/Mayur industries Pvt. Ltd/Metro Safety India Pvt Ltd or of equivalent Make. 15 Fire Alarm System 15.01 Individual standalone plastic body smoke alarm with adequate provision for fixing on wall / ceiling / roof. The unit to have sensor capable of covering area >40m2 and actuating an inbuilt alarm with loudness minimum 80 DB. Smoke alarm be powered by 9 Volt lithium batteries with an arrangement to test the battery and indicator to warn for low battery, including supply two Nos of battery.Make :- Fire End/AFO/Safe Guard) 15.02 Individual standalone plastic body heat alarm with adequate provision for fixing on wall / ceiling / roof. The unit to have sensor capable of detecting fixed temperature of 58oC and actuating an inbuilt alarm powered by 9 Volt lithium batteries with an arrangement to test the battery and indicator to warn for low battery, including supply two No of battery. (Make :- Fire End/AFO/Safe Guard) 15.03 Fire ball extinguisher of 1.3 Kg wt with suitable provision for wall mounting and capable of self activating on contact with flames. The unit to be maintenance free, non toxic, environment friendlye, and suitable for all type of fires. (Make :- AFO/Kanex/Fire Stop/Elide/Fire End/Safe Guard or equivalant) => Limited
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 11
Arunachal Pradesh View Result →
26.
Drinking Water Supply and Sanitation #10286025 Price Bid
Fixing Of Rate Contract For Repairs / Replacement To Electrical Equipment Installed At Different Wsss Of Phe Mechanical Sub-Division Shopian ( District Pulwama And Shopian ) For The Financial Year 2022-23- 1 Mechanical Transportation, Loading, Unloading And Handling Of Various Items Such As Pump Parts, Motors, Starters, Voltage Stabilizers, Coil Assemblies, Welding Tools & Plant, Etc. Using Appropriate Means Of Transport As Under: 2 Private Car, Auto-Rickshaw Or Similar With 1.0 Km Lead 3 Extra Per Kilometer For Lead >1.0 Kms Upto 5.0 Kms 4 Extra Per Kilometer For Lead >5.0 Kms Upto 10.0 Kms 5 Extra Per Kilometer For Lead >10.0 Kms Upto 20.0 Kms 6 Extra Per Kilometer For Lead >20.0 Kms Upto 30.0 Kms 7 Extra Per Kilometer For Lead >30.0 Kms Upto 50.0 Kms 8 Extra Per Kilometer For Lead >50.0 Kms Upto 70.0 Kms 9 Load Carrier Auto, Mini Van Or Similar With 1.0 Km Lead 10 Extra Per Kilometer For Lead >1.0 Kms Upto 5.0 Kms 11 Extra Per Kilometer For Lead >5.0 Kms Upto 10.0 Kms 12 Extra Per Kilometer For Lead >10.0 Kms Upto 20.0 Kms 13 Extra Per Kilometer For Lead >20.0 Kms Upto 30.0 Kms 14 Extra Per Kilometer For Lead >30.0 Kms Upto 50.0 Kms 15 Extra Per Kilometer For Lead >50.0 Kms Upto 70.0 Kms 16 Mini Truck Like Tata Mobile, Bolero Camper Or Similar With 1.0 Km Lead 17 Extra Per Kilometer For Lead >1.0 Kms Upto 5.0 Kms 18 Extra Per Kilometer For Lead >5.0 Kms Upto 10.0 Kms 19 Extra Per Kilometer For Lead >10.0 Kms Upto 20.0 Kms 20 Extra Per Kilometer For Lead >20.0 Kms Upto 30.0 Kms 21 Extra Per Kilometer For Lead >30.0 Kms Upto 50.0 Kms 22 Extra Per Kilometer For Lead >50.0 Kms Upto 70.0 Kms 23 Dismantling Of 415V 3-Ph Voltage Stabilizer By Way Of Opening Of Top Lid, Disassembling Of Voltage Regulator, Removing Of All Incoming And Outgoing Connections, Taking Out Of Damaged Copper Legs After Removal Of Core, Etc. The Job Includes Draining Out Of T. Oil And Its Safe Placement For Further Refilling. 24 Upto 50 Kva 25 >50 Upto 100Kva 26 >100Kva Upto 250 Kva 27 Assembling Of All Parts Of 3-Ph Voltage Stabilizer, Connecting Of Leads Of All Incoming And Outgoing Connections And Refilling Of Old Drained Out Of T. Oil 28 Upto 50 Kva 29 >50 Upto 100Kva 30 >100Kva Upto 250 Kva 31 Greater Than 250 Kva 32 Isolating And Disconnecting Of All Incoming And Outgoing Leads From Autotransformer Starter. Draining Out Transformer Oil From The Oil Tank And Collecting In A Suitable Vessel. Taking Out The Damaged Autotransformer Coil Assembly From Oil Tank. 33 >60 Upto 200 Hp 34 Providing Of Transformer Oil Conforming To Is 335 ( Preferred Make: Power Oil / Indian Oil Servo / Hpcl ) 35 Filtration Of Existing / Reclaimed T-Oil At Suitable Temperature ( Inclusive Of All Logistics And Charges For Filtration Plant, Etc ) ( Process Loss Maximum Of 5% Allowed ) 36 Rewinding Burnt / Damaged Windings Of Voltage Stabilizer Coil Assembly ( Comprising Of Three Limbs ) Using Superior Quality Copper Wire Of Proper Gauge As Per Requirement With Superior Insulation. ( Note: The Unserviceable Scrap Copper Generated Shall Be Property Of The Firm And Is Taken Into Account For Estimation Of Rates ) . 37 10Kva Rating 38 25Kva Rating 39 30Kva Rating 40 40Kva Rating 41 50Kva Rating 42 75Kva Rating 43 100Kva Rating 44 150Kva Rating 45 175Kva Rating 46 200Kva Rating 47 Removing Of Damagedplate Type Voltage Regulator Switch From 3 Phase , 415 ±15 % Volt Voltage Stabilizer And Providing And Fitting Of New Plate Type Voltage Regulator Switch Having Copper Contact Points With 6 Steps. The Job Includes Cost On Account Of Skilled / Semi-Skilled Labour Required For Work 48 10Kva Rating 49 25Kva Rating 50 30Kva Rating 51 40Kva Rating 52 50Kva Rating 53 75Kva Rating 54 100Kva Rating 55 150Kva Rating 56 175Kva Rating 57 200Kva Rating 58 Providing And Replacement Of Copper Contact Points On Regulator Plate 59 Impregnation / Heat Treatment Ofwinding Assembly Of 3 Phase, 415 ±15 % Volt Voltage Stabilizerby Way Of Keeping It In An Electric Oven For About 24 Hours And At Approperate Temperature. 60 10Kva Rating 61 25Kva Rating 62 30Kva Rating 63 40Kva Rating 64 50Kva Rating 65 75Kva Rating 66 100Kva Rating 67 150Kva Rating 68 175Kva Rating 69 200Kva Rating 70 Removing Of Damaged Copper Connection Terminal Bolt With Washer And Nut From3 Phase , 415 ±15 % Volt Voltage Stabilizer And Providing And Fitting Of New Copper Connection Terminal Bolt With Nut And Washer. 71 10Kva Rating 72 25Kva Rating 73 30Kva Rating 74 40Kva Rating 75 50Kva Rating 76 75Kva Rating 77 100Kva Rating 78 150Kva Rating 79 175Kva Rating 80 200Kva Rating 81 Hiring Of Portable Welding Set / Soldering Equipment Etc. Excluding Power Charges 82 Arresting Of Leakage In, 3 Phase , 415 ±15 % Volt Voltage Stabilizer Tank Along With Radiator Fins / Tubesby Way Of Soldering / Welding At The Cracked Spot ( Average Length Of Spot = 1 Inch ) 83 Providing And Fitting Of New Mug After Removing Old Damaged Mug Starter. 84 Mug 6, 6-10 Amp Relay 85 Mug 6, 9-14 Amp Relay 86 Mug 10, 13-21 Amp Relay 87 Mug 10, 20-32 Amp Relay 88 Mug 10, 28-42 Amp Relay 89 Mug 15, 11-18 Amp Relay 90 Mug 15, 13-22 Amp Relay 91 Mug 20, 9-14 Amp Relay 92 Mug 20H, 20-32 Amp Relay 93 Mug 20H, 28-42 Amp Relay 94 Mug 30, 20-33 Amp Relay 95 Mug 30, 30-50 Amp Relay 96 Mug 40, 30-50 Amp Relay 97 Mug 40, 36-60 Amp Relay 98 Mug 50, 36-50 Amp Relay 99 Mug 50, 45-75 Amp Relay 100 Mug 75, 45-75 Amp Relay 101 Mug 75, 66-110 Amp Relay 102 Poviding And Fitting Of 3-Pole Contactor Assemblyfor Mug - Submersible Starters 103 L&T, Mu1 104 L&T, Mu1h 105 L&T, Mu2 106 L&T, Mu3 107 L&T, Mk1 108 L&T, Ml2w 109 L&T, Ml3w 110 L&T, Ml4 W 111 L&T, Ml6w 112 Providing And Fitting Of Contactor Kit Set Tomug Submersible Starter 113 L&T, Mu1 114 L&T, U1h 115 L&T, Mu2 116 L&T, Mu3 117 Providing And Fitting Of Relay For Fasd , Mug Submersible Starters 118 Mk1 11-18 119 Mk1 13-22 120 Mu1 121 Mu2 9-14 A 122 Mu2 13-21 A 123 Mu2 15-25 A 124 Mu220-32 A 125 Mu2 24-38 A 126 Mu2 28-42 A 127 Mn5 20-33 128 Mn5 30-50 129 Mn5 36-60 130 Mn5 45-75 131 Mn5 66-110 132 Providing And Fitting Ofsingle Phase Preventer Of Mug Submersible Staters. 133 L&T, Sz5 134 L&T, Sdz5 135 Providing And Fitting Of Terminal Block 136 30 A-5Way 137 60 A-3 Way 138 100 A-3 Way 139 125 A-3Way 140 Indicating Lamps For Mug Starters 141 Indicating Lamp Red 415 V 142 Indicating Lamp Greeen 415 V 143 Spare Lamp, Mr-G Controller 144 Rocker Switch For Mug Starter 145 Rocker Switch ( For Mu-G6 To Mu-G20 ) 146 Rocker Switch ( For Mu-G30 To Mu-G75 ) 147 Voltage Selector Switch 148 Volt-Ammeter For Mug Starter 149 Volt-Ammeter 500V 30A 150 Volt-Ammeter 500V 60A 151 Volt-Ammeter 500V 0-75A 152 Volt-Ammeter 500V 0-100A 153 Volt-Ammeter 500V 0-125A 154 30A Ammeter Spare For Mr-G Controller 155 Volt Ammeter ( 30A, 300V Ac ) For 3-30 Sec Or 12-20 Sec. 156 Electronic Star -Delta Timer For Mug Starters 157 Electronic Star -Delta Timer Type St100, 160 - 500V, For 3-30 Sec Or 12-20 Sec. 158 Providing And Fitting Of Mu Coil 240 / 360 / 415 V To Mug Submersible Starter 159 Providing And Fitting Of Mu1 / Mu1h / Mu2 / Mu3 Contact Bridge 160 Providing And Fitting Of Mu1 / Mu2 Relay Extention Nob To Mug Submersible Starter 161 Providing And Fitting Of Mu1 / M, U1h / Mu2 / Mu3housing To Mug Submersible Starter 162 Providing And Fitting Of Mu1 Single Moving Contact To Mug Submersible Starter 163 Providing And Fitting Of Mu1h Single Moving Contact To Mug Submersible Starter 164 Providing And Fitting Of Mu2 Single Moving Contact To Mug Submersible Starter 165 Providing And Fitting Of Mu3 Single Moving Contact To Mug Submersible Starter 166 Electronic Star -Delta 167 Providing And Fitting Of New Mccb Thermal Release Type 168 100 A25 Ka 3 Pole 169 100 A36 Ka 4 Pole 170 160 A50 Ka 3 Pole 171 160 A50 Ka 4 Pole 172 200 A50ka 3 Pole 173 200 A50ka 4 Pole 174 250 A50ka 4 Pole 175 400 A50ka 4 Pole 176 630 A50ka 4 Pole 177 Providing And Fitting Of 3-Pole Contactor ( Ac-3 Duty ) With Specified Coil Voltage: 178 L&T Ml 2 179 L&T Ml 3 180 L&T Ml 4 181 L&T Ml 6 182 L&T Ml 12 183 L&T Mnx 50 184 L&T Mnx 70 185 L&T Mnx 80 186 L&T Mnx 95 187 L&T Mnx 110 188 L&T Mnx 140 189 L&T Mnx 185 190 L&T Mnx 225 191 L&T Mnx 250 192 Providing And Fitting Of New Coil With Specified Coil Voltage For Contactors As Under: 193 9A To 45A Ac-3 Rating ( Siemens 3Tf / L&T Type Mo / Schneider ) 194 L&T Ml 2 / 3 195 L&T Ml 4 / 6 196 L&T Ml 10 / 12 197 L&T Mnx 50 / 60 / 70 198 L&T Mnx 80 / 95 / 110 199 L&T Mnx 140 / 185 / 225 200 Providing And Fitting Of New Contact Kit Set For Contactors 201 32A Ac-3 Rating ( Siemens 3Tf / L&T Type Mo / Schneider ) 202 L&T Ml 2 203 L&T Ml 3 204 L&T Ml 4 205 L&T Ml 6 206 L&T Ml 10 207 Providing And Fitting Of Auxillary / Control Relay ( L&T Mx0 Or Similar ) For Ac Control 208 Providing And Fitting Of Auxillary / Control Relay ( L&T Mn0 Or Similar ) For Dc Control 209 Providing And Fitting Of ( 1No+1Nc ) Side Mounting Auxillary Contact Block ( For L&T / Schneider Electric Make Contactors ) . 210 Providing And Fitting Of Front Mounting Auxillary Contact Block Having 04 Contacts ( All Combinations ) ( For L&T / Schneider Electric / Siemens Make Contactors ) 211 Providing And Fitting Of 96X96 Flush Mounting 3-Phase Led Ammeter / Voltmeter Of Class 1 Accuracy ( Make: L&T / Schneider / Rishabh / Ae ) 212 Providing And Fitting Of Flush Type Analog Moving Iron Ac Meter As Under: ( Make: Rishabh / Ae / C&S / Bch ) 213 48X48mm 500V Voltmeter 214 96X96mm 500V Voltmeter 215 144X144mm 500V Voltmeter 216 96X96mm Ammeter ( 5A Ct Operated ) 217 Providing And Fitting Of Flush Type Frequency Meter With Range 45-55Hz: ( Make: Rishabh / Ae / L&T / Schneider / Bch ) 218 Providing And Fitting Of Led Phase Indicator With Surge Protection ( L&T / Teknic / Abb / Bch / Schneider Or Any Other Reputed Make ) 219 Providing And Fitting 3 Phase, 3 / 4 Wire Adjustable Under & Over Voltage Monitoring Relay ( Minilec Vct D2 Or Equivalent ) 220 Providing, Fitting And Setting Of 415V Auto Reset Single Phase Preventor ( L&T / Minilec / Bch Or Equivalent Make ) 221 50V Or Less Unbalance & 1 C / Odin Mounted 222 50V Or Less Unbalance & 1 C / Opanel Wall Mounted 223 70V Or Less Unbalance & 2 C / Odin Mounted 224 Providing And Fitting Of 32A Dp Switch ( Anchor / Ssk Or Any Other Reputed Make ) 225 Providing Of Hrc Fuses ( 2A - 32A ) Ratings 226 Providing And Fitting Of Fuse Holders For Fuses Upto 32A Rating 227 Providing And Fixing Pvc Panel Trunking With Cover 228 15X15mm 229 25X25mm 230 Providing And Fitting Of Terminal Block 100A - 3 Way 231 Providing And Crimping Of Various Aluminium Tube Lugs ( Dowells / Action / Or Any Other Reputed Make ) With Tapping, Insulation As Under: 232 16 Sq. Mm 233 25 Sq. Mm 234 35 Sq. Mm 235 50 Sq. Mm 236 70 Sq. Mm 237 95 Sq. Mm 238 120 Sq. Mm 239 150 Sq. Mm 240 185 Sq. Mm 241 Providing And Crimping Of Various Copper Tube Lugs ( Dowells / Action / Or Any Other Reputed Make ) With Tapping, Insulation As Under: 242 16 Sq. Mm 243 25 Sq. Mm 244 35 Sq. Mm 245 50 Sq. Mm 246 70 Sq. Mm 247 95 Sq. Mm 248 120 Sq. Mm 249 150 Sq. Mm 250 185 Sq. Mm 251 Providing, Fitting Of Submersible Cable Of Below Mentioned Specifications 252 6 Sqmm 253 10 Sqmm 254 16 Sqmm 255 25 Sqmm 256 35 Sqmm 257 Providing And Fitting Ofpvc Iinsulated Copper Cable As Per Is 694-Along With Thimbling As Per Requirments 258 Size:16 Sq.Mm1 Core Lt 1.1Kv 259 Size:25 Sq.Mm1 Core Lt 1.1Kv 260 Size:35 Sq.Mm1 Core Lt 1.1Kv 261 Size:50 Sq.Mm1 Core Lt 1.1Kv 262 Size:70 Sq.Mm1 Core Lt 1.1Kv 263 Size:95 Sq.Mm1 Core Lt 1.1Kv 264 Providing And Fitting Of 2 Core, 3 Core, 3.5-Core, Xlpe, 1.1Kv And 11Kv Grade Armoured Aluminum Cable Of Various Sizes Conforming To Is: 7098 Part 1St As Service Line From The Ht Transformer To Control Panel Including Necessary Thimbling, Crimping, Taping Etc. 265 10 Sq Mm, 2 Core Lt 1.1 Kv 266 35 Sq Mm, 3 Core Lt 1.1 Kv 267 35 Sq Mm, 3.5 Core Lt 1.1 Kv 268 50 Sq Mm, 3.5 Core Lt 1.1 Kv 269 70 Sq Mm, 3.5 Core Lt 1.1 Kv 270 95 Sq Mm, 3.5 Core Lt 1.1 Kv 271 120 Sq Mm, Single Core Lt 1.1 Kv 272 Providing And Fitting Of New 4-Pole, 415 V Manually Operated On Load Change Over Switch In Open Execution The Job Includes Extraction Of Existing Ones 273 63 A 274 100 A 275 125 A 276 160 A 277 200 A 278 250 A 279 315 A 280 400 A 281 630 A 282 Providing And Fitting Of New 4-Pole, 415 V Manually Operated On Load Change Over Switchfitted In Sheet Metal Enclusure Duly Power Painted, Vermin Proof With Side Operating Handle The Job Includes Extraction Of Existing Ones 283 63 A 284 100 A 285 125 A 286 160 A 287 200 A 288 250 A 289 315 A 290 400 A 291 630 A 292 Providing And Fitting Of New 4-Pole, 415 V Manually Operated Off Load Change Over Switchfitted In Sheet Metal Enclusure Duly Power Painted, Vermin Proof With Side Operating Handle The Job Includes Extraction Of Existing Ones 293 63 A 294 100 A 295 125 A 296 160 A 297 200 A 298 250 A 299 315 A 300 400 A 301 630 A 302 Providing And Fitting Of Pvc Insulated 1100V Flexible Copper Cable ( Frls ) For Electrical Installations As Under ( Preferred Makes: Finolex / Anchor / L&T / Havells / Kei / Polycab ) 303 1.0 Sqmm 304 1.5 Sqmm 305 2.5 Sqmm 306 4.0 Sqmm 307 6.0 Sqmm 308 10.0 Sqmm 309 16.0 Sqmm 310 2X1.5 Sqmm 311 2X2.5 Sqmm 312 2X6 Sqmm ( Aluminium Unarmoured ) 313 Providing And Installation Of Spn Sheet Steel Enclosed Distribution Boxes - Single Door ( Make: L&T / Legrand / Hager / Havells / Benlo ) 314 4 Way 315 8 Way 316 12 Way 317 16 Way 318 Providing And Installation Of ‘B’ Series Mcb 240V, 50Hz, 10Ka Suitable For Lighting And Other Domestic Loads ( Preferred Make: L&T / Legrand / Hager / Havells / Schneider ) 319 6-32A Sp 320 40A Sp 321 6-32A Dp 322 40A Dp 323 100A 4P Isolator 324 Providing And Installation Of Change Over Switches Of Metal Enclosure 240V 50Hz ( Preferred Make: Anchor / Ssk / Havells / L&T ) 325 2-Pole 16A 415V 326 2-Pole 32A 415V 327 4-Pole 32A 415V 328 Providing And Installation Of Busbar Chamber 3-Ph 4 Bar Heavy Duty Copper Strips With Rating As Under ( Preferred Make: Havells / Ssk / L&T ) 329 63A 415V 330 100A 415V 331 200A 415V 332 Supplying And Laying 25Mm X 5Mm G.I Strip At 0.50 Metre Below Ground As Strip Earth Electrode, Including Connection / Terminating With G.I. Nut, Bolt, Spring, Washer Etc. As Required. 333 Providing And Fixing 6 Swg Dia G.I. Wire On Surface Or In Recess For Loop Earthing Along With Existing Surface / Recessed Conduit / Submain Wiring / Cable As Required. 334 Providing And Fixing 25 Mm X 5 Mm G.I. Strip On Surface Or In Recess With Gi Saddles And Allied Fittings For Connections Etc. As Required. 335 Credit Value For Scrap Copper 336 Hiring Charges Of Skilled Electrician ( For Fiiting Of Various Substation Itemsetc ) : 337 Hiring Charges Of Labourer For Support Of Electrician.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 6
Jammu And Kashmir View Result →
27.
Drinking Water Supply and Sanitation #10286010 Price Bid
Fixing Of Rate Contract For Repairs / Replacement To Electrical Equipment Installed At Different Wsss Of Phe Mechanical Sub-Division Bijbehara ( District Anantnag And Kulgam ) For The Financial Year 2022-23- 1 Mechanical Transportation, Loading, Unloading And Handling Of Various Items Such As Pump Parts, Motors, Starters, Voltage Stabilizers, Coil Assemblies, Welding Tools & Plant, Etc. Using Appropriate Means Of Transport As Under: 2 Private Car, Auto-Rickshaw Or Similar With 1.0 Km Lead 3 Extra Per Kilometer For Lead >1.0 Kms Upto 5.0 Kms 4 Extra Per Kilometer For Lead >5.0 Kms Upto 10.0 Kms 5 Extra Per Kilometer For Lead >10.0 Kms Upto 20.0 Kms 6 Extra Per Kilometer For Lead >20.0 Kms Upto 30.0 Kms 7 Extra Per Kilometer For Lead >30.0 Kms Upto 50.0 Kms 8 Extra Per Kilometer For Lead >50.0 Kms Upto 70.0 Kms 9 Load Carrier Auto, Mini Van Or Similar With 1.0 Km Lead 10 Extra Per Kilometer For Lead >1.0 Kms Upto 5.0 Kms 11 Extra Per Kilometer For Lead >5.0 Kms Upto 10.0 Kms 12 Extra Per Kilometer For Lead >10.0 Kms Upto 20.0 Kms 13 Extra Per Kilometer For Lead >20.0 Kms Upto 30.0 Kms 14 Extra Per Kilometer For Lead >30.0 Kms Upto 50.0 Kms 15 Extra Per Kilometer For Lead >50.0 Kms Upto 70.0 Kms 16 Mini Truck Like Tata Mobile, Bolero Camper Or Similar With 1.0 Km Lead 17 Extra Per Kilometer For Lead >1.0 Kms Upto 5.0 Kms 18 Extra Per Kilometer For Lead >5.0 Kms Upto 10.0 Kms 19 Extra Per Kilometer For Lead >10.0 Kms Upto 20.0 Kms 20 Extra Per Kilometer For Lead >20.0 Kms Upto 30.0 Kms 21 Extra Per Kilometer For Lead >30.0 Kms Upto 50.0 Kms 22 Extra Per Kilometer For Lead >50.0 Kms Upto 70.0 Kms 23 Dismantling Of 415V 3-Ph Voltage Stabilizer By Way Of Opening Of Top Lid, Disassembling Of Voltage Regulator, Removing Of All Incoming And Outgoing Connections, Taking Out Of Damaged Copper Legs After Removal Of Core, Etc. The Job Includes Draining Out Of T. Oil And Its Safe Placement For Further Refilling. 24 Upto 50 Kva 25 >50 Upto 100Kva 26 >100Kva Upto 250 Kva 27 Assembling Of All Parts Of 3-Ph Voltage Stabilizer, Connecting Of Leads Of All Incoming And Outgoing Connections And Refilling Of Old Drained Out Of T. Oil 28 Upto 50 Kva 29 >50 Upto 100Kva 30 >100Kva Upto 250 Kva 31 Greater Than 250 Kva 32 Isolating And Disconnecting Of All Incoming And Outgoing Leads From Autotransformer Starter. Draining Out Transformer Oil From The Oil Tank And Collecting In A Suitable Vessel. Taking Out The Damaged Autotransformer Coil Assembly From Oil Tank. 33 >60 Upto 200 Hp 34 Providing Of Transformer Oil Conforming To Is 335 ( Preferred Make: Power Oil / Indian Oil Servo / Hpcl ) 35 Filtration Of Existing / Reclaimed T-Oil At Suitable Temperature ( Inclusive Of All Logistics And Charges For Filtration Plant, Etc ) ( Process Loss Maximum Of 5% Allowed ) 36 Rewinding Burnt / Damaged Windings Of Voltage Stabilizer Coil Assembly ( Comprising Of Three Limbs ) Using Superior Quality Copper Wire Of Proper Gauge As Per Requirement With Superior Insulation. ( Note: The Unserviceable Scrap Copper Generated Shall Be Property Of The Firm And Is Taken Into Account For Estimation Of Rates ) . 37 10Kva Rating 38 30Kva Rating 39 50Kva Rating 40 75Kva Rating 41 100Kva Rating 42 150Kva Rating 43 175Kva Rating 44 200Kva Rating 45 250Kva Rating 46 Removing Of Damagedplate Type Voltage Regulator Switch From 3 Phase , 415 ±15 % Volt Voltage Stabilizer And Providing And Fitting Of New Plate Type Voltage Regulator Switch Having Copper Contact Points With 6 Steps. The Job Includes Cost On Account Of Skilled / Semi-Skilled Labour Required For Work 47 10Kva Rating 48 30Kva Rating 49 50Kva Rating 50 75Kva Rating 51 100Kva Rating 52 150Kva Rating 53 175Kva Rating 54 200Kva Rating 55 250Kva Rating 56 Providing And Replacement Of Copper Contact Points On Regulator Plate 57 Impregnation / Heat Treatment Ofwinding Assembly Of 3 Phase, 415 ±15 % Volt Voltage Stabilizerby Way Of Keeping It In An Electric Oven For About 24 Hours And At Approperate Temperature. 58 10Kva Rating 59 30Kva Rating 60 50Kva Rating 61 75Kva Rating 62 100Kva Rating 63 150Kva Rating 64 175Kva Rating 65 200Kva Rating 66 250Kva Rating 67 Removing Of Damaged Copper Connection Terminal Bolt With Washer And Nut From3 Phase , 415 ±15 % Volt Voltage Stabilizer And Providing And Fitting Of New Copper Connection Terminal Bolt With Nut And Washer. 68 10Kva Rating 69 30Kva Rating 70 50Kva Rating 71 75Kva Rating 72 100Kva Rating 73 150Kva Rating 74 175Kva Rating 75 200Kva Rating 76 250Kva Rating 77 500Kva Rating 78 Hiring Of Portable Welding Set / Soldering Equipment Etc. Excluding Power Charges 79 Arresting Of Leakage In, 3 Phase , 415 ±15 % Volt Voltage Stabilizer Tank Along With Radiator Fins / Tubesby Way Of Soldering / Welding At The Cracked Spot ( Average Length Of Spot = 1 Inch ) 80 Providing And Fitting Of New Mug After Removing Old Damaged Mug Starter. 81 Mug 6, 6-10 Amp Relay 82 Mug 6, 9-14 Amp Relay 83 Mug 10, 13-21 Amp Relay 84 Mug 10, 20-32 Amp Relay 85 Mug 10, 28-42 Amp Relay 86 Mug 15, 11-18 Amp Relay 87 Mug 15, 13-22 Amp Relay 88 Mug 20, 9-14 Amp Relay 89 Mug 20H, 20-32 Amp Relay 90 Mug 20H, 28-42 Amp Relay 91 Mug 30, 20-33 Amp Relay 92 Mug 30, 30-50 Amp Relay 93 Mug 40, 30-50 Amp Relay 94 Mug 40, 36-60 Amp Relay 95 Mug 50, 36-50 Amp Relay 96 Mug 50, 45-75 Amp Relay 97 Mug 75, 45-75 Amp Relay 98 Mug 75, 66-110 Amp Relay 99 Poviding And Fitting Of 3-Pole Contactor Assemblyfor Mug - Submersible Starters 100 L&T, Mu1 101 L&T, Mu1h 102 L&T, Mu2 103 L&T, Mu3 104 L&T, Mk1 105 L&T, Ml2w 106 L&T, Ml3w 107 L&T, Ml4 W 108 L&T, Ml6w 109 Providing And Fitting Of Contactor Kit Set Tomug Submersible Starter 110 L&T, Mu1 111 L&T, U1h 112 L&T, Mu2 113 L&T, Mu3 114 Providing And Fitting Of Relay For Fasd , Mug Submersible Starters 115 Mk1 11-18 116 Mk1 13-22 117 Mu1 118 Mu2 9-14 A 119 Mu2 13-21 A 120 Mu2 15-25 A 121 Mu220-32 A 122 Mu2 24-38 A 123 Mu2 28-42 A 124 Mn5 20-33 125 Mn5 30-50 126 Mn5 36-60 127 Mn5 45-75 128 Mn5 66-110 129 Providing And Fitting Ofsingle Phase Preventer Of Mug Submersible Staters. 130 L&T, Sz5 131 L&T, Sdz5 132 Providing And Fitting Of Terminal Block 133 30 A-5Way 134 60 A-3 Way 135 100 A-3 Way 136 125 A-3Way 137 Indicating Lamps For Mug Starters 138 Indicating Lamp Red 415 V 139 Indicating Lamp Greeen 415 V 140 Spare Lamp, Mr-G Controller 141 Rocker Switch For Mug Starter 142 Rocker Switch ( For Mu-G6 To Mu-G20 ) 143 Rocker Switch ( For Mu-G30 To Mu-G75 ) 144 Voltage Selector Switch 145 Volt-Ammeter For Mug Starter 146 Volt-Ammeter 500V 30A 147 Volt-Ammeter 500V 60A 148 Volt-Ammeter 500V 0-75A 149 Volt-Ammeter 500V 0-100A 150 Volt-Ammeter 500V 0-125A 151 30A Ammeter Spare For Mr-G Controller 152 Volt Ammeter ( 30A, 300V Ac ) For 3-30 Sec Or 12-20 Sec. 153 Electronic Star -Delta Timer For Mug Starters 154 Electronic Star -Delta Timer Type St100, 160 - 500V, For 3-30 Sec Or 12-20 Sec. 155 Providing And Fitting Of Mu Coil 240 / 360 / 415 V To Mug Submersible Starter 156 Providing And Fitting Of Mu1 / Mu1h / Mu2 / Mu3 Contact Bridge 157 Providing And Fitting Of Mu1 / Mu2 Relay Extention Nob To Mug Submersible Starter 158 Providing And Fitting Of Mu1 / M, U1h / Mu2 / Mu3housing To Mug Submersible Starter 159 Providing And Fitting Of Mu1 Single Moving Contact To Mug Submersible Starter 160 Providing And Fitting Of Mu1h Single Moving Contact To Mug Submersible Starter 161 Providing And Fitting Of Mu2 Single Moving Contact To Mug Submersible Starter 162 Providing And Fitting Of Mu3 Single Moving Contact To Mug Submersible Starter 163 Electronic Star -Delta 164 Providing And Fitting Of New Mccb Thermal Release Type 165 100 A25 Ka 3 Pole 166 100 A36 Ka 4 Pole 167 160 A50 Ka 3 Pole 168 160 A50 Ka 4 Pole 169 200 A50ka 3 Pole 170 200 A50ka 4 Pole 171 250 A50ka 4 Pole 172 400 A50ka 4 Pole 173 630 A50ka 4 Pole 174 Providing And Fitting Of 3-Pole Contactor ( Ac-3 Duty ) With Specified Coil Voltage: 175 L&T Ml 2 176 L&T Ml 3 177 L&T Ml 4 178 L&T Ml 6 179 L&T Ml 12 180 L&T Mnx 50 181 L&T Mnx 70 182 L&T Mnx 80 183 L&T Mnx 95 184 L&T Mnx 110 185 L&T Mnx 140 186 L&T Mnx 185 187 L&T Mnx 225 188 L&T Mnx 250 189 Providing And Fitting Of New Coil With Specified Coil Voltage For Contactors As Under: 190 9A To 45A Ac-3 Rating ( Siemens 3Tf / L&T Type Mo / Schneider ) 191 L&T Ml 2 / 3 192 L&T Ml 4 / 6 193 L&T Ml 10 / 12 194 L&T Mnx 50 / 60 / 70 195 L&T Mnx 80 / 95 / 110 196 L&T Mnx 140 / 185 / 225 197 Providing And Fitting Of New Contact Kit Set For Contactors 198 32A Ac-3 Rating ( Siemens 3Tf / L&T Type Mo / Schneider ) 199 L&T Ml 2 200 L&T Ml 3 201 L&T Ml 4 202 L&T Ml 6 203 L&T Ml 10 204 Providing And Fitting Of Auxillary / Control Relay ( L&T Mx0 Or Similar ) For Ac Control 205 Providing And Fitting Of Auxillary / Control Relay ( L&T Mn0 Or Similar ) For Dc Control 206 Providing And Fitting Of ( 1No+1Nc ) Side Mounting Auxillary Contact Block ( For L&T / Schneider Electric Make Contactors ) . 207 Providing And Fitting Of Front Mounting Auxillary Contact Block Having 04 Contacts ( All Combinations ) ( For L&T / Schneider Electric / Siemens Make Contactors ) 208 Providing And Fitting Of 96X96 Flush Mounting 3-Phase Led Ammeter / Voltmeter Of Class 1 Accuracy ( Make: L&T / Schneider / Rishabh / Ae ) 209 Providing And Fitting Of Flush Type Analog Moving Iron Ac Meter As Under: ( Make: Rishabh / Ae / C&S / Bch ) 210 48X48mm 500V Voltmeter 211 96X96mm 500V Voltmeter 212 144X144mm 500V Voltmeter 213 96X96mm Ammeter ( 5A Ct Operated ) 214 Providing And Fitting Of Flush Type Frequency Meter With Range 45-55Hz: ( Make: Rishabh / Ae / L&T / Schneider / Bch ) 215 Providing And Fitting Of Led Phase Indicator With Surge Protection ( L&T / Teknic / Abb / Bch / Schneider Or Any Other Reputed Make ) 216 Providing And Fitting 3 Phase, 3 / 4 Wire Adjustable Under & Over Voltage Monitoring Relay ( Minilec Vct D2 Or Equivalent ) 217 Providing, Fitting And Setting Of 415V Auto Reset Single Phase Preventor ( L&T / Minilec / Bch Or Equivalent Make ) 218 50V Or Less Unbalance & 1 C / Odin Mounted 219 50V Or Less Unbalance & 1 C / Opanel Wall Mounted 220 70V Or Less Unbalance & 2 C / Odin Mounted 221 Providing And Fitting Of 32A Dp Switch ( Anchor / Ssk Or Any Other Reputed Make ) 222 Providing Of Hrc Fuses ( 2A - 32A ) Ratings 223 Providing And Fitting Of Fuse Holders For Fuses Upto 32A Rating 224 Providing And Fixing Pvc Panel Trunking With Cover 225 15X15mm 226 25X25mm 227 Providing And Fitting Of Terminal Block 100A - 3 Way 228 Providing And Crimping Of Various Aluminium Tube Lugs ( Dowells / Action / Or Any Other Reputed Make ) With Tapping, Insulation As Under: 229 16 Sq. Mm 230 25 Sq. Mm 231 35 Sq. Mm 232 50 Sq. Mm 233 70 Sq. Mm 234 95 Sq. Mm 235 120 Sq. Mm 236 150 Sq. Mm 237 185 Sq. Mm 238 Providing And Crimping Of Various Copper Tube Lugs ( Dowells / Action / Or Any Other Reputed Make ) With Tapping, Insulation As Under: 239 16 Sq. Mm 240 25 Sq. Mm 241 35 Sq. Mm 242 50 Sq. Mm 243 70 Sq. Mm 244 95 Sq. Mm 245 120 Sq. Mm 246 150 Sq. Mm 247 185 Sq. Mm 248 Providing, Fitting Of Submersible Cable Of Below Mentioned Specifications 249 6 Sqmm 250 10 Sqmm 251 16 Sqmm 252 25 Sqmm 253 35 Sqmm 254 Providing And Fitting Ofpvc Iinsulated Copper Cable As Per Is 694-Along With Thimbling As Per Requirments 255 Size:16 Sq.Mm1 Core Lt 1.1Kv 256 Size:25 Sq.Mm1 Core Lt 1.1Kv 257 Size:35 Sq.Mm1 Core Lt 1.1Kv 258 Size:50 Sq.Mm1 Core Lt 1.1Kv 259 Size:70 Sq.Mm1 Core Lt 1.1Kv 260 Size:95 Sq.Mm1 Core Lt 1.1Kv 261 Providing And Fitting Of 2 Core, 3 Core, 3.5-Core, Xlpe, 1.1Kv And 11Kv Grade Armoured Aluminum Cable Of Various Sizes Conforming To Is: 7098 Part 1St As Service Line From The Ht Transformer To Control Panel Including Necessary Thimbling, Crimping, Taping Etc. 262 10 Sq Mm, 2 Core Lt 1.1 Kv 263 35 Sq Mm, 3 Core Lt 1.1 Kv 264 35 Sq Mm, 3.5 Core Lt 1.1 Kv 265 50 Sq Mm, 3.5 Core Lt 1.1 Kv 266 70 Sq Mm, 3.5 Core Lt 1.1 Kv 267 95 Sq Mm, 3.5 Core Lt 1.1 Kv 268 120 Sq Mm, Single Core Lt 1.1 Kv 269 Providing And Fitting Of New 4-Pole, 415 V Manually Operated On Load Change Over Switch In Open Execution The Job Includes Extraction Of Existing Ones 270 63 A 271 100 A 272 125 A 273 160 A 274 200 A 275 250 A 276 315 A 277 400 A 278 630 A 279 Providing And Fitting Of New 4-Pole, 415 V Manually Operated On Load Change Over Switchfitted In Sheet Metal Enclusure Duly Power Painted, Vermin Proof With Side Operating Handle The Job Includes Extraction Of Existing Ones 280 63 A 281 100 A 282 125 A 283 160 A 284 200 A 285 250 A 286 315 A 287 400 A 288 630 A 289 Providing And Fitting Of New 4-Pole, 415 V Manually Operated Off Load Change Over Switchfitted In Sheet Metal Enclusure Duly Power Painted, Vermin Proof With Side Operating Handle The Job Includes Extraction Of Existing Ones 290 63 A 291 100 A 292 125 A 293 160 A 294 200 A 295 250 A 296 315 A 297 400 A 298 630 A 299 Providing And Fitting Of Pvc Insulated 1100V Flexible Copper Cable ( Frls ) For Electrical Installations As Under ( Preferred Makes: Finolex / Anchor / L&T / Havells / Kei / Polycab ) 300 1.0 Sqmm 301 1.5 Sqmm 302 2.5 Sqmm 303 4.0 Sqmm 304 6.0 Sqmm 305 10.0 Sqmm 306 16.0 Sqmm 307 2X1.5 Sqmm 308 2X2.5 Sqmm 309 2X6 Sqmm ( Aluminium Unarmoured ) 310 Providing And Installation Of Spn Sheet Steel Enclosed Distribution Boxes - Single Door ( Make: L&T / Legrand / Hager / Havells / Benlo ) 311 4 Way 312 8 Way 313 12 Way 314 16 Way 315 Providing And Installation Of ‘B’ Series Mcb 240V, 50Hz, 10Ka Suitable For Lighting And Other Domestic Loads ( Preferred Make: L&T / Legrand / Hager / Havells / Schneider ) 316 6-32A Sp 317 40A Sp 318 6-32A Dp 319 40A Dp 320 100A 4P Isolator 321 Providing And Installation Of Change Over Switches Of Metal Enclosure 240V 50Hz ( Preferred Make: Anchor / Ssk / Havells / L&T ) 322 2-Pole 16A 415V 323 2-Pole 32A 415V 324 4-Pole 32A 415V 325 Providing And Installation Of Busbar Chamber 3-Ph 4 Bar Heavy Duty Copper Strips With Rating As Under ( Preferred Make: Havells / Ssk / L&T ) 326 63A 415V 327 100A 415V 328 200A 415V 329 Supplying And Laying 25Mm X 5Mm G.I Strip At 0.50 Metre Below Ground As Strip Earth Electrode, Including Connection / Terminating With G.I. Nut, Bolt, Spring, Washer Etc. As Required. 330 Providing And Fixing 6 Swg Dia G.I. Wire On Surface Or In Recess For Loop Earthing Along With Existing Surface / Recessed Conduit / Submain Wiring / Cable As Required. 331 Providing And Fixing 25 Mm X 5 Mm G.I. Strip On Surface Or In Recess With Gi Saddles And Allied Fittings For Connections Etc. As Required. 332 Credit Value For Scrap Copper 333 Hiring Charges Of Skilled Electrician ( For Fiiting Of Various Substation Itemsetc ) : 334 Hiring Charges Of Labourer For Support Of Electrician.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
Jammu And Kashmir View Result →
28.
Drinking Water Supply and Sanitation #10284437 Price Bid
Fixing Of Rate Contract For Repairs / Replacement To Electrical Equipment Installed At Different Wsss Of Phe Mechanical Sub-Division Bijbehara ( District Anantnag And Kulgam ) For The Financial Year 2023-24- 1 Mechanical Transportation, Loading, Unloading And Handling Of Various Items Such As Pump Parts, Motors, Starters, Voltage Stabilizers, Coil Assemblies, Welding Tools & Plant, Etc. Using Appropriate Means Of Transport As Under: 2 Private Car, Auto-Rickshaw Or Similar With 1.0 Km Lead 3 Extra Per Kilometer For Lead >1.0 Kms Upto 5.0 Kms 4 Extra Per Kilometer For Lead >5.0 Kms Upto 10.0 Kms 5 Extra Per Kilometer For Lead >10.0 Kms Upto 20.0 Kms 6 Extra Per Kilometer For Lead >20.0 Kms Upto 30.0 Kms 7 Load Carrier Auto, Mini Van Or Similar With 1.0 Km Lead 8 Extra Per Kilometer For Lead >1.0 Kms Upto 5.0 Kms 9 Extra Per Kilometer For Lead >5.0 Kms Upto 10.0 Kms 10 Extra Per Kilometer For Lead >10.0 Kms Upto 20.0 Kms 11 Extra Per Kilometer For Lead >20.0 Kms Upto 30.0 Kms 12 Mini Truck Like Tata Mobile, Bolero Camper Or Similar With 1.0 Km Lead 13 Extra Per Kilometer For Lead >1.0 Kms Upto 5.0 Kms 14 Extra Per Kilometer For Lead >5.0 Kms Upto 10.0 Kms 15 Extra Per Kilometer For Lead >10.0 Kms Upto 20.0 Kms 16 Extra Per Kilometer For Lead >20.0 Kms Upto 30.0 Kms 17 Voltage Stabilizersdismantling Of 415V 3-Ph Voltage Stabilizer By Way Of Opening Of Top Lid, Disassembling Of Voltage Regulator, Removing Of All Incoming And Outgoing Connections, Taking Out Of Damaged Copper Legs After Removal Of Core, Etc. The Job Includes Draining Out Of T. Oil And Its Safe Placement For Further Refilling. 18 Upto 50 Kva 19 >50 Upto 100Kva 20 >100Kva Upto 250 Kva 21 Greater Than 250 Kva 22 Assembling Of All Parts Of 3-Ph Voltage Stabilizer, Connecting Of Leads Of All Incoming And Outgoing Connections And Refilling Of Old Drained Out Of T. Oil 23 Upto 50 Kva 24 >50 Upto 100Kva 25 >100Kva Upto 250 Kva 26 Greater Than 250 Kva 27 Isolating And Disconnecting Of All Incoming And Outgoing Leads From Autotransformer Starter. Draining Out Transformer Oil From The Oil Tank And Collecting In A Suitable Vessel. Taking Out The Damaged Autotransformer Coil Assembly From Oil Tank. 28 >60 Upto 200 Hp 29 Providing Of Transformer Oil Conforming To Is 335 ( Preferred Make: Power Oil / Indian Oil Servo / Hpcl ) 30 Filtration Of Existing / Reclaimed T-Oil At Suitable Temperature ( Inclusive Of All Logistics And Charges For Filtration Plant, Etc ) ( Process Loss Maximum Of 5% Allowed ) 31 Rewinding Burnt / Damaged Windings Of Voltage Stabilizer Coil Assembly ( Comprising Of Three Limbs ) Using Superior Quality Copper Wire Of Proper Gauge As Per Requirement With Superior Insulation. ( Note: The Unserviceable Scrap Copper Generated Shall Be Property Of The Firm And Is Taken Into Account For Estimation Of Rates ) . 32 10Kva Rating 33 30Kva Rating 34 50Kva Rating 35 75Kva Rating 36 100Kva Rating 37 150Kva Rating 38 175Kva Rating 39 200Kva Rating 40 250Kva Rating 41 Removing Of Damagedplate Type Voltage Regulator Switch From 3 Phase , 415 ±15 % Volt Voltage Stabilizer And Providing And Fitting Of New Plate Type Voltage Regulator Switch Having Copper Contact Points With 6 Steps. The Job Includes Cost On Account Of Skilled / Semi-Skilled Labour Required For Work 42 10Kva Rating 43 30Kva Rating 44 50Kva Rating 45 75Kva Rating 46 100Kva Rating 47 150Kva Rating 48 175Kva Rating 49 200Kva Rating 50 250Kva Rating 51 Impregnation / Heat Treatment Ofwinding Assembly Of 3 Phase, 415 ±15 % Volt Voltage Stabilizerby Way Of Keeping It In An Electric Oven For About 24 Hours And At Approperate Temperature. 52 10Kva Rating 53 30Kva Rating 54 50Kva Rating 55 75Kva Rating 56 100Kva Rating 57 150Kva Rating 58 175Kva Rating 59 200Kva Rating 60 250Kva Rating 61 Removing Of Damaged Copper Connection Terminal Bolt With Washer And Nut From3 Phase, 415 ±15 % Volt Voltage Stabilizer And Providing And Fitting Of New Copper Connection Terminal Bolt With Nut And Washer. 62 10Kva Rating 63 30Kva Rating 64 50Kva Rating 65 75Kva Rating 66 100Kva Rating 67 150Kva Rating 68 175Kva Rating 69 200Kva Rating 70 250Kva Rating 71 500Kva Rating 72 Hiring Of Portable Welding Set / Soldering Equipment Etc. Excluding Power Charges 73 Arresting Of Leakage In, 3 Phase , 415 ±15 % Volt Voltage Stabilizer Tank Along With Radiator Fins / Tubesby Way Of Soldering / Welding At The Cracked Spot ( Average Length Of Spot = 1 Inch ) 74 Providing And Replacement Of Copper Contact Points On Regulator Plate 75 Providing And Fitting Of Lv Copper Terminal Connectors With Allied Insulation _ ( For Finished Weight Of The Connector ) 76 Starterisolating And Disconnecting Of All Incoming And Outgoing Leads From Autotransformer Starter. Draining Out Transformer Oil From The Oil Tank And Collecting In A Suitable Vessel. Taking Out The Damaged Autotransformer Coil Assembly From Oil Tank. 77 Upto 60 Hp Rating 78 >60 Upto 200 Hp 79 >200 Hp Upto 350 Hp 80 Greater Than 350 Hp 81 Fitting Of Autotransformer Coil Assembly In The Starter Oil Tank, Filling Of T.Oil In The Tank, Connecting All Leads And Load Testing Of The Starter. 82 Upto 60 Hp Rating 83 >60 Upto 200 Hp 84 >200 Hp Upto 350 Hp 85 Greater Than 350 Hp 86 Contactorsproviding And Fitting Of 3-Pole Contactor ( Ac-3 Duty ) With Specified Coil Voltage: 87 L&T Ml 1.5 88 L&T Ml 2 89 L&T Ml 3 90 L&T Ml 4 91 L&T Ml 6 92 L&T Ml 12 93 L&T Mnx 50 94 L&T Mnx 70 95 L&T Mnx 80 96 L&T Mnx 95 97 L&T Mnx 110 98 L&T Mnx 140 99 L&T Mnx 185 100 L&T Mnx 225 101 L&T Mnx 250 102 Mk1 103 Mk2 104 Mu1 105 Mu1h 106 Mu2 107 Mu3 108 Ml2w 109 Ml3w 110 Ml4w 111 Ml6w 112 Schneider Electric Lc1f265 ( Without Coil ) 113 Schneider Electric Lc1f330 ( Without Coil ) 114 Schneider Electric Lc1f400 ( Without Coil ) 115 Schneider Electric Lc1f630 ( Without Coil ) 116 32A Ac-3 Rating ( Siemens 3Tf / L&T Type Mo / Schneider ) 117 45A Ac-3 Rating With 2No + 2Nc Auxillary Contacts ( Siemens 3Tf / L&T Type Mo / Schneider ) 118 Providing And Fitting Of New Ac Coil With Specified Coil Voltage For Contactors: 119 9A To 45A Ac-3 Rating ( Siemens 3Tf / Equivalent ) 120 L&T Ml 2 / 3 121 L&T Ml 4 / 6 122 L&T Ml 10 / 12 123 L&T Mnx 50 / 70 / 80 124 L&T Mnx 95 / 110 / 140 125 L&T Mnx 185 / 225 / 250 126 L&T Mnx 300 / 400 127 L&T Mnx 550 / 650 128 Schneider Electric Lc1f185 / Lc1f225 129 Schneider Electric Lc1f265 / Lc1f330 130 Schneider Electric Lc1f400 131 Schneider Electric Lc1f630 132 Providing And Fitting Of New Contact Kit Set For Contactors 133 32A Ac-3 Rating ( Siemens 3Tf / Equivalent ) 134 L&T Ml 2 135 L&T Ml 3 136 L&T Ml 4 137 L&T Ml 6 138 L&T Ml 10 139 L&T Ml 12 140 Providing And Fitting Of Auxillary Contactors / Control Relay 141 L&T Mx0 Having 04 Contacts ( All Combinations ) For Ac Control 142 L&T Mx0 Having 04 Contacts ( All Combinations ) For Dc Control 143 L&T Ml ( 1No+1Nc ) Side Mounting Auxillary Contact Block 144 L&T Mnx / Mcx Front Mounting Type Having 04 Contacts ( All Combinations ) 145 Timing Relaysproviding, Fitting And Setting Up Of Single Range Auto Reset Synchronous On Delay Timer ( L&T Or Equivalent Make ) 146 Providing, Fitting And Setting Of Electropneumatic Timing Relay With Timing Range Upto 60S; Coil Voltage 415V Ac ( Bch Or Equivalent Make ) . 147 ( 2No + 2Nc ) Double Block; On Delay 148 ( 2No + 2Nc ) Double Block; On & Off Delay 149 Providing And Fitting Of Spares For Electropneumatic Timing Relay ( Bch Make Or Equivalent ) 150 ( 2No + 2Nc ) Contact Block 151 Magnetic Coil 415V Ac 152 Magnet Frame Assembly Without Coil 153 Providing, Fitting And Setting Of Din Mounted Electronic Timer ( L&T Gic Or Equivalent Make ) 154 Star Delta ( Range From 3S - 120S ) 240V Ac 155 Star Delta ( Range From 3S - 30S ) 240 - 415V Ac 156 On Delay ( 0.3S - 30Hrs ) 240V Ac 157 Thermal Overload Relayproviding, Fitting And Setting Of Thermal Overload Relay Of Specified Relay Range ( Make: L&T Mn2 ) 158 Relay Range In Between 0.2A To 15A 159 14-23A 160 20-33A 161 24-40A 162 Providing, Fitting And Setting Of Thermal Overload Relay Of Specified Relay Range ( Make: L&T Mn5 ) 163 20-33A 164 30-50A 165 36-60A 166 45-75A 167 66-110A 168 Providing, Fitting And Setting Of Thermal Overload Relay Of Specified Relay Range 169 L&T Ml1 ( Relay Range In Between 0.15A To 16A ) 170 L&T Ml2 / 3 ( Relay Ranges In Between 9A To 42A ) 171 Miscellaneous 172 Providing And Fitting Of Bakelite Connection Plate Minimum 10Mm Thick As Per Given Size For Autotransformer With Holes For Connection Studs Drilled At Requisite Spots 173 Complete Servicing Of Control Wiring Of Ats Including Checking, Tightening Of Connections, Tapping And Insulation As Per Requirement. 174 Complete Replacement Of Suitable Copper Control Wiring Of Ats Including Cable Ties, Connections, Tapping And Insulation As Per Requirement. 175 Oil Immersed Starter Sparesproviding And Replacement Of Operating Coil For Oil Immersed Semi-Automatic Starter, Upto 40Hp 176 Providing And Fitting Of Heavy Duty Contact Kit Set For Semi-Automatic / Fully Automatic Sd Oil Immersed Starters ( Set Of 03 Moving And 06 Stationary Contacts ) , Upto 40 Hp 177 Spares For Oil Immersed Manual Starters 178 Fixed Finger Contact 179 Moving Tip Contact 180 No Volt Coil 181 Moving Drum Contact ( Starters Upto 40Hp ) 182 Moving Drum Contact ( Starters > 40Hp ) 183 Base Plate Bakelite / Dmc ( Starters Upto 40Hp ) 184 Base Plate Bakelite / Dmc ( Starters > 40Hp ) 185 Steam Carrier Assembly ( Starters Upto 40Hp ) 186 Steam Carrier Assembly ( Starters > 40Hp ) 187 Sequence Shaft ( Starters Upto 40Hp ) 188 Sequence Shaft ( Starters > 40Hp ) 189 Bakelite Tube For Sequence Shaft ( Starters Upto 40Hp ) 190 Bakelite Tube For Sequence Shaft ( Starters > 40Hp ) 191 Trip Rod Assembly ( Starters Upto 40Hp ) 192 Trip Rod Assembly ( Starters > 40Hp ) 193 Lock Lever 194 Cam Assembly 195 Oil Dashpot Assembly 196 Overload Coil ( Set Of 03 Nos. ) Upto 20Hp 197 Overload Coil ( Set Of 03 Nos. ) 30- 40Hp 198 Overload Coil ( Set Of 03 Nos. ) 50- 60Hp 199 Overload Coil ( Set Of 03 Nos. ) 70- 80Hp 200 Overload Coil ( Set Of 03 Nos. ) 90- 100Hp 201 L&T Mu-G Submersible Pump Controller Sparesvolt-Ammeter 500V, 202 Electronic Star-Delta Timer 3-30S 203 Providing And Fitting Of Terminal Block 204 60A - 3 Way 205 100A - 3 Way 206 Single Phase Preventing Relay Sz5 Type 207 Single Phase Preventing Relay Sdz5 Type 208 Providing, Fitting And Setting Of Thermal Overload Relay Of Specified Relay Range ( Make: L&T ) 209 Mk1 ( All Ranges ) 210 Mu1 ( All Ranges ) 211 Mu2 Relays Of Following Ranges 212 6 -10 A, 9 - 14A 213 13 - 21A 214 15 - 25A 215 20 - 32A 216 24 - 38A 217 28 - 42A 218 Providing And Fitting Of Standard Operating Coil For Following Contactors 219 Mk1 / Mk2 220 Mu1 / Mu2 / Mu3 221 Providing And Fitting Of Contact Bridge Without Contact Of Following Contactors 222 Mk1 / Mk2 223 Mu1 / Mu2 / Mu3 224 Providing And Fitting Of Single Moving Contact Of Following Contactors 225 Mk1 226 Mk2 227 Mu1 228 Mu2 229 Mu3 230 Indicating Lamps 231 Rocker Switch 232 Rocker Switch ( Mug-G6 To Mug G20 ) 233 Rocker Switch ( Mug-G30 To Mug G75 ) 234 Voltage Selector Switch 235 30A Ammeter Spare For Mr-G Controller 236 Volt Ammeter ( 30A, 300V Ac ) For 3-30 Sec Or 12-20 Sec. 237 Electronic Star -Delta Timer For Mug Starters 238 Electronic Star -Delta Timer Type St100, 160 - 500V, For 3-30 Sec Or 12-20 Sec. 239 Providing And Fitting Of Mu Coil 240 / 360 / 415 V To Mug Submersible Starter 240 Providing And Fitting Of Mu1 / Mu1h / Mu2 / Mu3 Contact Bridge 241 Providing And Fitting Of Mu1 / Mu2 Relay Extension Job To Mug Submersible Starter 242 Providing And Fitting Of Mu1 / M, U1h / Mu2 / Mu3housing To Mug Submersible Starter 243 Providingand Fitting Of New Mug After Removing Old Damaged Ones 244 Mug 6, 6-10 Amp Relay 245 Mug 6, 9-14 Amp Relay 246 Mug 10, 13-21 Amp Relay 247 Mug 10, 20-32 Amp Relay 248 Mug 10, 28-42 Amp Relay 249 Mug 15, 11-18 Amp Relay 250 Mug 15, 13-22 Amp Relay 251 Mug 20, 9-14 Amp Relay 252 Mug 20H, 20-32 Amp Relay 253 Mug 20H, 28-42 Amp Relay 254 Mug 30, 20-33 Amp Relay 255 Mug 30, 30-50 Amp Relay 256 Mug 40, 30-50 Amp Relay 257 Mug 40, 36-60 Amp Relay 258 Mug 50, 36-50 Amp Relay 259 Mug 50, 45-75 Amp Relay 260 Mug 75, 45-75 Amp Relay 261 Mug 75, 66-110 Amp Relay 262 Mccbproviding And Fitting Of 3-Pole 415V Mccb With Thermal Magnetic Release Having 36Ka Breaking Capacity ( Ics= 100% Icu ) ( Make: L&T D-Sine Or Equivalent ) Having Max. Of Thermal Release Range As Under: 263 Upto And Including 100A ( Ics= 50% Icu ) 264 125A 265 160A 266 200A 267 250A 268 400A 269 Providing And Fitting Of 3-Pole 415V Mccb With Thermal Magnetic Release Having 50Ka Breaking Capacity Ics = 100% Icu ( Make: L&T D-Sine Or Equivalent ) Having Max. Of Thermal Release Range As Under: 270 125A 271 160A 272 200A 273 250A 274 400A 275 630A 276 Providing Of Set Of Spreader Terminals For Above 3-Pole Mccbs 277 100A 278 125A 279 250A 280 400A 281 630A 282 Providing And Fitting Of 4-Pole 415V Mccb With Thermal Magnetic Release Having 50Ka Breaking Capacity Ics = 100% Icu ( Make: L&T D-Sine Or Similar ) Having Max. Of Thermal Release Range As Under: 283 125A 284 160A 285 200A 286 250A 287 400A 288 630A 289 Spares For Acb ( L&T C-Power ) Providing And Fitting Of Pole Assembly For Draw Out Type Acb ( L&T C-Power ) 290 Upto 1250A 291 2000A 292 Providing And Fitting Of Arc Chute ( 440V ) For Acb ( L&T C-Power ) 293 Upto 1250A 294 1600 - 2000A 295 Providing And Fitting Of Jaw Contact For Acb ( L&T C-Power ) 296 630-1000A 297 1250A 298 1600A / 2000A 299 Providing And Fitting Of Fixed Arcing Contact For Acb ( L&T C-Power ) 300 800- 1600A 301 2000A 302 Providing And Fitting Of Moving Arcing Contact For Acb ( L&T C-Power ) 303 800- 2000A 304 Providing And Fitting Of Shunt Release For Acb ( L&T C-Power ) 305 Providing And Fitting Of Under Voltage Release For Acb ( L&T C-Power ) 306 Providing And Fitting Of Moving Arcing Contact For Acb ( L&T C-Power ) 307 Providing And Fitting Of Terminal Adaptor For Draw Out L&T C-Power Acb Of Ratings As Under: 308 Upto 800 - 1250A 309 1600 - 2000A 310 Providing And Fitting Of Thermal-Magnetic Release ( Type Dn1 ) For L&T C-Power Acb 311 Providing And Fitting Of Ct For Dn1 Type L&T C-Power Acb 312 800 / 1000A 313 1250 / 1600A 314 2000A 315 Providing And Fitting Of Main Spring For 3-Pole Acb ( L&T C-Power ) 316 800- 1600A 317 2000A 318 Providing Of Racking Handle For Draw-Out Type Acbs ( L&T C-Power ) Rating Upto 2000A 319 Providing And Replacement Of Spring Charging Motor ( Ac / Dc ) 320 Providing And Replacement Of Motor Limit Switch 321 Instrumentation And Panel Accessoriesproviding And Fitting Of 96X96 Flush Mounting 3-Phase Led Ammeter / Voltmeter Of Class 1 Accuracy ( Make: L&T / Schneider / Rishabh / Ae ) 322 Providing And Fitting Of Flush Type Analog Moving Iron Ac Meter As Under: ( Make: Rishabh / Ae / C&S / Bch ) 323 48X48mm 500V Voltmeter 324 96X96mm 500V Voltmeter 325 144X144mm 500V Voltmeter 326 96X96mm Ammeter ( 5A Ct Operated ) 327 Providing And Fitting Of Flush Type Frequency Meter With Range 45-55Hz: ( Make: Rishabh / Ae / L&T / Schneider / Bch ) 328 Providing And Fitting Of 10A Line Current Ammeter Selector Switch With Off ( Make: L&T / Rishabh / Ae / Teknic ) 329 Providing And Fitting Of 10A Voltmeter Selector Switch With Off ( Make: L&T / Rishabh / Ae / Teknic ) 330 Providing And Fitting Of Tape Insulated Ring Type Metering Current Transformers ( Ae / Rishabh / Crompton / Kilburn ) As Under: 331 100 / 5A Or 150 / 5A - Class 1 - Burden 5Va 332 200 / 5A - Class 1 - Burden 10Va 333 400 / 5A - Class 1 - Burden 15Va 334 600 / 5A - Class 1 - Burden 15Va 335 800 / 5A - Class 1 - Burden 15Va 336 1000 / 5A - Class 1 - Burden 15Va 337 2000 / 5A - Class 1 - Burden 15Va 338 Extra For 1A Secondary Upto 600 / 1A Over Corresponding Rate 339 Providing And Fitting Of Analog Vac Hour Meter ( Make: L&T Or Equivalent Make ) 340 Din Mounting Type 341 Flush Mounting Type 342 Providing And Fitting Of Flush Or Projecting Head Push Button With Contact Block ( L&T / Teknic / Abb / Bch / Schneider Or Any Other Reputed Make ) 343 Providing And Fitting Of Led Phase Indicator With Surge Protection ( L&T / Teknic / Abb / Bch / Schneider Or Any Other Reputed Make ) 344 Providing And Fitting 3 Phase, 3 / 4 Wire Adjustable Under & Over Voltage Monitoring Relay ( Minilec Vct D2 Or Equivalent ) 345 Providing, Fitting And Setting Of 415V Auto Reset Single Phase Preventor ( L&T / Minilec / Bch Or Equivalent Make ) 346 50V Or Less Unbalance & 1 C / Odin Mounted 347 50V Or Less Unbalance & 1 C / Opanel Wall Mounted 348 70V Or Less Unbalance & 2 C / Odin Mounted 349 Providing And Fitting Of 32A Dp Switch ( Anchor / Ssk Or Any Other Reputed Make ) 350 Providing Of Hrc Fuses ( 2A - 32A ) Ratings 351 Providing And Fitting Of Fuse Holders For Fuses Upto 32A Rating 352 Providing And Fixing Upvc Panel Trunking With Cover 353 15X15mm 354 25X25mm 355 Terminals / Lugsproviding And Crimping Of Various Aluminium Tube Lugs ( Dowells / Action / Or Any Other Reputed Make ) With Tapping, Insulation As Under: 356 16 Sq. Mm 357 25 Sq. Mm 358 35 Sq. Mm 359 50 Sq. Mm 360 70 Sq. Mm 361 95 Sq. Mm 362 120 Sq. Mm 363 150 Sq. Mm 364 185 Sq. Mm 365 225 Sq. Mm 366 240 Sq. Mm 367 300 Sq. Mm 368 Providing And Crimping Of Various Copper Tube Lugs ( Dowells / Action / Or Any Other Reputed Make ) With Tapping, Insulation As Under: 369 16 Sq. Mm 370 25 Sq. Mm 371 35 Sq. Mm 372 50 Sq. Mm 373 70 Sq. Mm 374 95 Sq. Mm 375 120 Sq. Mm 376 150 Sq. Mm 377 185 Sq. Mm 378 225 Sq. Mm 379 240 Sq. Mm 380 300 Sq. Mm 381 Cablesproviding And Fitting Of Pvc Insulated 1100V Flat 3-Core Industrial Copper Cable For Submersible Pump Motors ( Preferred Makes: Finolex / L&T / Havells / Kei / Polycab ) 382 1.5 Sqmm 383 2.5 Sqmm 384 4.0 Sqmm 385 6.0 Sqmm 386 10.0 Sqmm 387 16.0 Sqmm 388 25.0 Sqmm 389 35.0 Sqmm 390 Providing And Fitting Of Xlpe Insulated, 1100V Single Core Armoured Industrial Copper Cable As Under ( Preferred Make: Finolex / Gloster / Havells / Kei / Polycab ) 391 16.0 Sqmm 392 25 Sqmm 393 35 Sqmm 394 50 Sqmm 395 70 Sqmm 396 95 Sqmm 397 120 Sqmm 398 150 Sqmm 399 185 Sqmm 400 240 Sqmm 401 300 Sqmm 402 400 Sqmm 403 Providing And Fitting Of Xlpe Insulated, 1100V Single Core Industrial Armoured Aluminium Cable As Under ( Preferred Make: Finolex / Gloster / Havells / Kei / Polycab ) 404 16 Sqmm 405 25 Sqmm 406 35 Sqmm 407 50 Sqmm 408 70 Sqmm 409 95 Sqmm 410 120 Sqmm 411 150 Sqmm 412 185 Sqmm 413 240 Sqmm 414 300 Sqmm 415 Providing And Fitting Of Xlpe Insulated, 1100V 3.5-Core Industrial Armoured Aluminium Cable As Per Is 7098 ( Preferred Make: Finolex / Gloster / Havells / Kei / Polycab ) 416 25 Sqmm 417 35 Sqmm 418 50 Sqmm 419 70 Sqmm 420 95 Sqmm 421 120 Sqmm 422 150 Sqmm 423 185 Sqmm 424 240 Sqmm 425 300 Sqmm 426 Wiringproviding And Fitting Of Pvc Insulated 1100V Flexible Copper Cable ( Frls ) For Electrical Installations As Under ( Preferred Makes: Finolex / Anchor / L&T / Havells / Kei / Polycab ) 427 1.0 Sqmm 428 1.5 Sqmm 429 2.5 Sqmm 430 4.0 Sqmm 431 6.0 Sqmm 432 10.0 Sqmm 433 16.0 Sqmm 434 2X1.5 Sqmm 435 2X2.5 Sqmm 436 2X6 Sqmm ( Aluminium Unarmoured ) 437 Conduits 438 Providing And Fixing 25Mm Pvc Round Conduit ( Medium ) With Allied Pvc Fittings 439 Providing And Fixing Upvc Trunking 25X16mm With Allied Fittings 440 Providing And Fixing Polypropylene Corrugated Flexible Conduit 441 25Mm 442 32Mm 443 Providing And Fitting Perforated Ms Cable Trays Including Horizontal And Vertical Bends, Reducers, Tees, Cross Members And Other Accessories As Required And Duly Suspended From The Ceiling With Ms Suspenders Or Fixing On Cantilever Supports And Including Painting Etc As Required. 444 100 X 50 X 1.6Mm 445 150 X 50 X 1.6Mm 446 Electrical Fitingsproviding And Fitting Of Various Electrical Fittings As Under ( Preferred Makes: Anchor / Ssk / Havells ) 447 Switch-6A-Sp-1Way, 240V, 50 Hz, Ac. 448 Switch-6A-Sp-2Way, 240V, 50 Hz, Ac. 449 Cord Switches:- Providing And Fitting Of Cord Switch-6A-Sp-1Way, 240V, 50 Hz, Ac / Hanging Bell Push. 450 Bell Push 240V, 50 Hz, Ac. 451 6A Socket:- Providing And Fitting Of6a-2 / 3 Pin-Universal Socket, 240V, 50 Hz, Ac. 452 Neon Indicator 453 Mini Telephone Jack 454 Fan Regulator ( Mini ) With Rotary Step 455 Fan Regulator ( Deluxe ) With Rotary Step 456 Shuttered-3 Pin Socket And Switch ( Box / Recessed ) - 20A-Sp-1 Way, 230V 50 Hz, Ac. 457 Plug Top 15 / 16A 3 Pin ( Isi Marked ) 458 32A Tp Switch 415V With Neon 459 32A Dp Switch 240V With Neon 460 Surface Mounting Box For Switches As Follows: 461 1 Gang Box 462 2 Gang Box 463 3 Gang Box 464 4 Gang Box 465 5 Gang Box 466 6 Gang Box 467 7 Gang Box 468 4 Gang Box ( Double Domestic ) 469 Providing, Fixing, Testing Of 6A Ceiling Rose 470 Providing And Installation Of Pendant / Angle / Batten Holders 6A 240V 471 Providing And Installation Of Spn Sheet Steel Enclosed Distribution Boxes - Single Door ( Make: L&T / Legrand / Hager / Havells / Benlo ) 472 4 Way 473 8 Way 474 12 Way 475 16 Way 476 Providing And Installation Of ‘B’ Series Mcb 240V, 50Hz, 10Ka Suitable For Lighting And Other Domestic Loads ( Preferred Make: L&T / Legrand / Hager / Havells / Schneider ) 477 6-32A Sp 478 40A Sp 479 6-32A Dp 480 40A Dp 481 100A 4P Isolator 482 Providing And Installation Of Change Over Switches Of Metal Enclosure 240V 50Hz ( Preferred Make: Anchor / Ssk / Havells / L&T ) 483 2-Pole 16A 415V 484 2-Pole 32A 415V 485 4-Pole 32A 415V 486 4-Pole 63A 415V 487 4-Pole 100A 415V 488 Providing And Installation Of Busbar Chamber 3-Ph 4 Bar Heavy Duty Copper Strips With Rating As Under ( Preferred Make: Havells / Ssk / L&T ) 489 63A 415V 490 100A 415V 491 200A 415V 492 Manpower 493 Hiring Charges Of Electrician ( For Troubleshooting / Revamping Of Existing Electrical Fitting, Etc. Exclusive Of Specified Works ) : 494 Hiring Charges Of Labourer For Support Of Electrician 495 Excavating Trenches Of Required Width For Pipes, Cables, Etc In All Kinds Of Soil Including Excavation For Sockets And Dressing Of Sides, Ramming Of Bottoms, Depth Upto 1.5 M, Including Getting Out The Excavated Soil, And Then Returning The Soil As Required, In Layers Not Exceeding 20 Cm In Depth, Including Consolidating Each Deposited Layer By Ramming, Watering, Etc. And Disposing Of Surplus Excavated Soil As Directed, Within A Lead Of 50 M 496 Pipes, Cables Etc, Not Exceeding 80 Mm Dia. 497 Pipes, Cables Etc. Exceeding 80 Mm Dia. But Not Exceeding 300 Mm Dia 498 Pipes, Cables Etc. Exceeding 300 Mm Dia But Not Exceeding 600 Mm Dia 499 Pipes, Cables Etc. Exceeding 600 Mm Dia But Not Exceeding 1200 Mm Dia 500 Extra For Excavating Trenches For Pipes, Cables Etc. In All Kinds Of Soil For Depth Exceeding 1.5 M, But Not Exceeding 3M. ( Rate Is Over Corresponding Basic Item For Depth Upto 1.5 Metre ) . 501 Extra For Excavating Trenches For Pipes, Cables, Etc, In All Kinds Of Soil For Depth Exceeding 3 M In Depth, But Not Exceeding 4.5 M. ( Rate Is Over Corresponding Basic Item For Depth Upto 1.5 Metre. )
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 5
Jammu And Kashmir View Result →
29.
Drinking Water Supply and Sanitation #10284422 Price Bid
Fixing Of Rate Contract For Repairs/Replacement To Electrical Equipment Installed At Different Wsss Of Phe Mechanical Sub-Division Pampore (District Pulwama) For The Financial Year 2023-24- 1 Mechanical transportation, loading, unloading and handling of various items such as pump parts, motors, starters, voltage stabilizers, coil assemblies, welding tools & plant, etc. using appropriate means of transport as under: 2 Private car, auto-rickshaw or similar with 1.0 km lead 3 Extra per kilometer for lead >1.0 kms upto 5.0 kms 4 Extra per kilometer for lead >5.0 kms upto 10.0 kms 5 Extra per kilometer for lead >10.0 kms upto 20.0 kms 6 Extra per kilometer for lead >20.0 kms upto 30.0 kms 7 Load carrier auto, mini van or similar with 1.0 km lead 8 Extra per kilometer for lead >1.0 kms upto 5.0 kms 9 Extra per kilometer for lead >5.0 kms upto 10.0 kms 10 Extra per kilometer for lead >10.0 kms upto 20.0 kms 11 Extra per kilometer for lead >20.0 kms upto 30.0 kms 12 Mini truck like Tata mobile, Bolero Camper or similar with 1.0 km lead 13 Extra per kilometer for lead >1.0 kms upto 5.0 kms 14 Extra per kilometer for lead >5.0 kms upto 10.0 kms 15 Extra per kilometer for lead >10.0 kms upto 20.0 kms 16 Extra per kilometer for lead >20.0 kms upto 30.0 kms 17 VOLTAGE STABILIZERSDismantling of 415V 3-ph Voltage Stabilizer by way of opening of top lid, disassembling of voltage regulator, removing of all incoming and outgoing connections, taking out of damaged copper legs after removal of core, etc. The job includes draining out of T. Oil and its safe placement for further refilling. 18 upto 50 kVA 19 >50 upto 100kVA 20 >100kVA upto 250 kVA 21 Greater than 250 kVA 22 Assembling of all parts of 3-ph Voltage Stabilizer, connecting of leads of all incoming and outgoing connections and refilling of old drained out of T. Oil 23 upto 50 kVA 24 >50 upto 100kVA 25 >100kVA upto 250 kVA 26 Greater than 250 kVA 27 Isolating and disconnecting of all incoming and outgoing leads from autotransformer starter. Draining out transformer oil from the oil tank and collecting in a suitable vessel. Taking out the damaged autotransformer coil assembly from oil tank. 28 >60 upto 200 HP 29 Providing of transformer oil conforming to IS 335 (Preferred make: Power oil/ Indian Oil Servo/ HPCL) 30 Filtration of existing/ reclaimed T-oil at suitable temperature (inclusive of all logistics and charges for filtration plant, etc)(Process loss maximum of 5% allowed) 31 Rewinding burnt/ damaged windings of voltage stabilizer coil assembly (comprising of three limbs) using superior quality copper wire of proper gauge as per requirement with superior insulation. (Note: The unserviceable scrap copper generated shall be property of the firm and is taken into account for estimation of rates). 32 10kVA rating 33 30kVA rating 34 50kVA rating 35 75kVA rating 36 100kVA rating 37 150kVA rating 38 175kVA rating 39 200kVA rating 40 250kVA rating 41 Removing of damagedplate type voltage regulator switch from 3 phase , 415 ±15 % Volt voltage stabilizer and providing and fitting of new plate type voltage regulator switch having copper contact points with 6 steps. the job includes cost on account of skilled/semi-skilled labour required for work 42 10kVA rating 43 30kVA rating 44 50kVA rating 45 75kVA rating 46 100kVA rating 47 150kVA rating 48 175kVA rating 49 200kVA rating 50 250kVA rating 51 Impregnation/heat treatment ofwinding assembly of 3 phase, 415 ±15 % Volt voltage stabilizerby way of keeping it in an electric oven for about 24 hours and at approperate temperature. 52 10kVA rating 53 30kVA rating 54 50kVA rating 55 75kVA rating 56 100kVA rating 57 150kVA rating 58 175kVA rating 59 200kVA rating 60 250kVA rating 61 Removing of damaged copper connection terminal bolt with washer and nut from3 phase, 415 ±15 % Volt voltage stabilizer and providing and fitting of new copper connection terminal bolt with nut and washer. 62 10kVA rating 63 30kVA rating 64 50kVA rating 65 75kVA rating 66 100kVA rating 67 150kVA rating 68 175kVA rating 69 200kVA rating 70 250kVA rating 71 500kVA rating 72 Hiring of portable welding set /soldering equipment etc. excluding power charges 73 Arresting of leakage in, 3 phase , 415 ±15 % Volt voltage stabilizer tank along with radiator fins/tubesby way of soldering/ welding at the cracked spot (average length of spot = 1 inch) 74 Providing and replacement of copper contact points on regulator plate 75 Providing and Fitting of LV copper terminal connectors with allied insulation _ (for finished weight of the connector) 76 STARTERIsolating and disconnecting of all incoming and outgoing leads from autotransformer starter. Draining out transformer oil from the oil tank and collecting in a suitable vessel. Taking out the damaged autotransformer coil assembly from oil tank. 77 upto 60 HP rating 78 >60 upto 200 HP 79 >200 HP upto 350 HP 80 greater than 350 HP 81 Fitting of autotransformer coil assembly in the starter oil tank, filling of t.oil in the tank, connecting all leads and load testing of the starter. 82 upto 60 HP rating 83 >60 upto 200 HP 84 >200 HP upto 350 HP 85 greater than 350 HP 86 CONTACTORSProviding and fitting of 3-pole contactor (AC-3 duty) with specified coil voltage: 87 L&T ML 1.5 88 L&T ML 2 89 L&T ML 3 90 L&T ML 4 91 L&T ML 6 92 L&T ML 12 93 L&T MNX 50 94 L&T MNX 70 95 L&T MNX 80 96 L&T MNX 95 97 L&T MNX 110 98 L&T MNX 140 99 L&T MNX 185 100 L&T MNX 225 101 L&T MNX 250 102 MK1 103 MK2 104 MU1 105 MU1H 106 MU2 107 MU3 108 ML2W 109 ML3W 110 ML4W 111 ML6W 112 Schneider Electric LC1F265 (without coil) 113 Schneider Electric LC1F330 (without coil) 114 Schneider Electric LC1F400 (without coil) 115 Schneider Electric LC1F630 (without coil) 116 32A AC-3 rating (Siemens 3TF/ L&T Type MO/ Schneider) 117 45A AC-3 rating with 2NO + 2NC auxillary contacts (Siemens 3TF/ L&T Type MO/ Schneider) 118 Providing and fitting of new AC coil with specified coil voltage for contactors: 119 9A to 45A AC-3 rating (Siemens 3TF/ equivalent) 120 L&T ML 2/ 3 121 L&T ML 4/ 6 122 L&T ML 10/ 12 123 L&T MNX 50/ 70/ 80 124 L&T MNX 95/ 110/ 140 125 L&T MNX 185/ 225/ 250 126 L&T MNX 300/ 400 127 L&T MNX 550/ 650 128 Schneider Electric LC1F185/ LC1F225 129 Schneider Electric LC1F265/ LC1F330 130 Schneider Electric LC1F400 131 Schneider Electric LC1F630 132 Providing and fitting of new Contact kit set for contactors 133 32A AC-3 rating (Siemens 3TF/equivalent) 134 L&T ML 2 135 L&T ML 3 136 L&T ML 4 137 L&T ML 6 138 L&T ML 10 139 L&T ML 12 140 Providing and fitting of auxillary contactors/ control relay 141 L&T MX0 having 04 contacts (all combinations) for AC control 142 L&T MX0 having 04 contacts (all combinations) for DC control 143 L&T ML (1NO+1NC) side mounting auxillary contact block 144 L&T MNX/MCX front mounting type having 04 contacts (all combinations) 145 TIMING RELAYSProviding, fitting and setting up of single range auto reset synchronous ON delay timer (L&T or equivalent make) 146 Providing, fitting and setting of electropneumatic timing relay with timing range upto 60s; coil voltage 415V AC (BCH or equivalent make) . 147 (2NO + 2NC) double block; ON delay 148 (2NO + 2NC) double block; ON & OFF delay 149 Providing and fitting of spares for electropneumatic timing relay (BCH make or equivalent) 150 (2NO + 2NC) contact block 151 Magnetic coil 415V AC 152 Magnet frame assembly without coil 153 Providing, fitting and setting of DIN mounted electronic Timer (L&T GIC or equivalent make) 154 Star Delta (range from 3s - 120s)240V AC 155 Star Delta (range from 3s - 30s)240 - 415V AC 156 ON delay (0.3s - 30hrs) 240V AC 157 THERMAL OVERLOAD RELAYProviding, fitting and setting of thermal overload relay of specified relay range(Make: L&T MN2) 158 Relay range in between 0.2A to 15A 159 14-23A 160 20-33A 161 24-40A 162 Providing, fitting and setting of thermal overload relay of specified relay range(Make: L&T MN5) 163 20-33A 164 30-50A 165 36-60A 166 45-75A 167 66-110A 168 Providing, fitting and setting of thermal overload relay of specified relay range 169 L&T ML1 (Relay range in between 0.15A to 16A) 170 L&T ML2/3 (Relay ranges in between 9A to 42A) 171 MISCELLANEOUS 172 Providing and fitting of bakelite connection plate minimum 10mm thick as per given size for autotransformer with holes for connection studs drilled at requisite spots 173 Complete servicing of control wiring of ATS including checking, tightening of connections, tapping and insulation as per requirement. 174 Complete replacement of suitable copper control wiring of ATS including cable ties, connections, tapping and insulation as per requirement. 175 OIL IMMERSED STARTER SPARESProviding and replacement of operating coil for oil immersed semi-automatic starter, upto 40HP 176 Providing and fitting of heavy duty contact kit set for semi-automatic/ fully automatic SD oil immersed starters (set of 03 moving and 06 stationary contacts), upto 40 HP 177 Spares for oil immersed manual starters 178 Fixed finger contact 179 Moving tip contact 180 No volt coil 181 Moving drum contact (starters upto 40HP) 182 Moving drum contact (starters > 40HP) 183 Base plate Bakelite/ DMC (starters upto 40HP) 184 Base plate Bakelite/ DMC (starters > 40HP) 185 Steam carrier assembly (starters upto 40HP) 186 Steam carrier assembly (starters > 40HP) 187 Sequence shaft (starters upto 40HP) 188 Sequence shaft (starters > 40HP) 189 Bakelite tube for Sequence shaft (starters upto 40HP) 190 Bakelite tube for Sequence shaft (starters > 40HP) 191 Trip rod assembly (starters upto 40HP) 192 Trip rod assembly (starters > 40HP) 193 Lock lever 194 Cam assembly 195 Oil dashpot assembly 196 Overload coil (set of 03 nos.) upto 20HP 197 Overload coil (set of 03 nos.) 30- 40HP 198 Overload coil (set of 03 nos.) 50- 60HP 199 Overload coil (set of 03 nos.) 70- 80HP 200 Overload coil (set of 03 nos.) 90- 100HP 201 L&T MU-G SUBMERSIBLE PUMP CONTROLLER SPARESVolt-Ammeter 500V, 202 Electronic Star-Delta Timer 3-30s 203 Providing and fitting of Terminal Block 204 60A - 3 way 205 100A - 3 way 206 Single phase preventing relay Sz5 type 207 Single phase preventing relay SDz5 type 208 Providing, fitting and setting of thermal overload relay of specified relay range(Make: L&T) 209 MK1 (all ranges) 210 MU1 (all ranges) 211 MU2 relays of following ranges 212 6 -10 A, 9 - 14A 213 13 - 21A 214 15 - 25A 215 20 - 32A 216 24 - 38A 217 28 - 42A 218 Providing and fitting of standard operating coil for following contactors 219 MK1/ MK2 220 MU1/ MU2/ MU3 221 Providing and fitting of contact bridge without contact of following contactors 222 MK1/ MK2 223 MU1/ MU2/ MU3 224 Providing and fitting of single moving contact of following contactors 225 MK1 226 MK2 227 MU1 228 MU2 229 MU3 230 Indicating lamps 231 Rocker switch 232 Rocker switch (MUG-G6 to MUG G20) 233 Rocker switch (MUG-G30 to MUG G75) 234 Voltage Selector switch 235 30A Ammeter Spare for MR-G Controller 236 Volt Ammeter (30A, 300V AC) for 3-30 sec or 12-20 sec. 237 Electronic star -Delta timer for MUG Starters 238 Electronic star -Delta timer type ST100, 160 - 500V, for 3-30 sec or 12-20 sec. 239 Providing and fitting of MU Coil 240/360/415 V to MUG submersible Starter 240 Providing and fitting of MU1/MU1H/MU2/MU3 contact bridge 241 Providing and fitting of MU1/MU2 Relay extension job to MUG submersible starter 242 Providing and fitting of MU1/M,U1H/MU2/MU3housing To MUG submersible starter 243 MCCBProviding and fitting of 3-pole 415V MCCB with thermal magnetic release having 36kA breaking capacity (Ics= 100% Icu) (Make: L&T d-sine or equivalent) having max. of thermal release range as under: 244 upto and including 100A (Ics= 50% Icu) 245 125A 246 160A 247 200A 248 250A 249 400A 250 Providing and fitting of 3-pole 415V MCCB with thermal magnetic release having 50kA breaking capacity Ics = 100% Icu (Make: L&T d-sine or equivalent) Having max. of thermal release range as under: 251 125A 252 160A 253 200A 254 250A 255 Providing of set of spreader terminals for above 3-pole MCCBs 256 100A 257 125A 258 250A 259 400A 260 630A 261 Providing and fitting of 4-pole 415V MCCB with thermal magnetic release having 50kA breaking capacity Ics = 100% Icu (Make: L&T d-sine or similar) Having max. of thermal release range as under: 262 125A 263 160A 264 200A 265 250A 266 SPARES FOR ACB (L&T C-POWER)Providing and fitting of pole assembly for draw out type ACB (L&T C-power) 267 upto 1250A 268 2000A 269 Providing and fitting of Arc Chute (440V) for ACB (L&T C-power) 270 upto 1250A 271 1600 - 2000A 272 Providing and fitting of Jaw contact for ACB (L&T C-power) 273 630-1000A 274 1250A 275 1600A/ 2000A 276 Providing and fitting of Fixed arcing contact for ACB (L&T C-power) 277 800- 1600A 278 2000A 279 Providing and fitting of Moving arcing contact for ACB (L&T C-power) 280 800- 2000A 281 Providing and fitting of Shunt release for ACB (L&T C-power) 282 Providing and fitting of Under Voltage Release for ACB (L&T C-power) 283 Providing and fitting of Moving arcing contact for ACB (L&T C-power) 284 Providing and fitting of Terminal Adaptor for Draw out L&T C-POWER ACB of ratings as under: 285 upto 800 - 1250A 286 1600 - 2000A 287 Providing and fitting of thermal-Magnetic Release (type DN1) for L&T C-power ACB 288 Providing and fitting of CT for DN1 type L&T C-power ACB 289 800/ 1000A 290 1250/ 1600A 291 2000A 292 Providing and fitting of main spring for 3-pole ACB (L&T C-power) 293 800- 1600A 294 2000A 295 Providing of racking handle for draw-out type ACBs (L&T C-power) rating upto 2000A 296 Providing and replacement of spring charging motor (AC/ DC) 297 Providing and replacement of motor limit switch 298 INSTRUMENTATION AND PANEL ACCESSORIESProviding and fitting of 96x96 flush mounting 3-phase LED ammeter/ voltmeter of Class 1 accuracy (Make: L&T/ Schneider/ Rishabh/ AE) 299 Providing and fitting of flush type analog moving iron AC meter as under:(Make: Rishabh/ AE/ C&S/ BCH) 300 48x48mm 500V voltmeter 301 96x96mm 500V voltmeter 302 144x144mm 500V voltmeter 303 96x96mm ammeter (5A CT operated) 304 Providing and fitting of flush type frequency meter with range 45-55Hz:(Make: Rishabh/ AE/ L&T/ Schneider/ BCH) 305 Providing and fitting of 10A line current ammeter selector switch with OFF (Make: L&T/Rishabh/ AE/ Teknic) 306 Providing and fitting of 10A voltmeter selector switch with OFF(Make: L&T/ Rishabh/ AE/ Teknic) 307 Providing and fitting of tape insulated ring type metering current transformers (AE/ Rishabh/ Crompton/ Kilburn) as under: 308 100/5A or 150/5A - Class 1 - Burden 5VA 309 200/5A - Class 1 - Burden 10VA 310 400/5A - Class 1 - Burden 15VA 311 600/5A - Class 1 - Burden 15VA 312 800/5A - Class 1 - Burden 15VA 313 1000/5A - Class 1 - Burden 15VA 314 2000/5A - Class 1 - Burden 15VA 315 Extra for 1A secondary upto 600/1A over corresponding rate 316 Providing and fitting of analog VAC hour meter(Make: L&T or equivalent make) 317 DIN mounting type 318 Flush mounting type 319 Providing and fitting of flush or projecting head push button with contact block (L&T/ Teknic/ ABB/ BCH/ Schneider or any other reputed make) 320 Providing and fitting of LED phase indicator with surge protection (L&T/ Teknic/ ABB/ BCH/ Schneider or any other reputed make) 321 Providing and fitting 3 Phase, 3/4 Wire adjustable Under & Over Voltage monitoring relay (Minilec VCT D2 or equivalent) 322 Providing, fitting and setting of 415V auto reset single phase preventor (L&T/ Minilec/ BCH or equivalent make) 323 50V or less unbalance & 1 C/ODIN mounted 324 50V or less unbalance & 1 C/OPanel wall mounted 325 70V or less unbalance & 2 C/ODIN mounted 326 Providing and fitting of 32A DP switch (Anchor/ SSK or any other reputed make) 327 Providing of HRC fuses (2A - 32A) ratings 328 Providing and fitting of Fuse holders for fuses upto 32A rating 329 Providing and fixing uPVC panel trunking with cover 330 15x15mm 331 25x25mm 332 TERMINALS/LUGSProviding and crimping of various aluminium tube lugs (Dowells/ Action/ or any other reputed make) with tapping, insulation as under: 333 16 sq. mm 334 25 sq. mm 335 35 sq. mm 336 50 sq. mm 337 70 sq. mm 338 95 sq. mm 339 120 sq. mm 340 150 sq. mm 341 185 sq. mm 342 225 sq. mm 343 240 sq. mm 344 300 sq. mm 345 Providing and crimping of various copper tube lugs (Dowells/ Action/ or any other reputed make) with tapping, insulation as under: 346 16 sq. mm 347 25 sq. mm 348 35 sq. mm 349 50 sq. mm 350 70 sq. mm 351 95 sq. mm 352 120 sq. mm 353 150 sq. mm 354 185 sq. mm 355 225 sq. mm 356 240 sq. mm 357 300 sq. mm 358 CABLESProviding and fitting of PVC insulated 1100V flat 3-core industrial copper cable for submersible pump motors (Preferred makes: Finolex/ L&T/ Havells/ KEI/ Polycab) 359 1.5 sqmm 360 2.5 sqmm 361 4.0 sqmm 362 6.0 sqmm 363 10.0 sqmm 364 16.0 sqmm 365 25.0 sqmm 366 35.0 sqmm 367 Providing and fitting of XLPE insulated, 1100V single core armoured industrial copper cable as under (Preferred make: Finolex/ Gloster/ Havells/ KEI/ Polycab) 368 16.0 sqmm 369 25 sqmm 370 35 sqmm 371 50 sqmm 372 70 sqmm 373 95 sqmm 374 120 sqmm 375 150 sqmm 376 185 sqmm 377 240 sqmm 378 300 sqmm 379 400 sqmm 380 Providing and fitting of XLPE insulated, 1100V single core industrial armoured aluminium cable as under (Preferred make: Finolex/ Gloster/ Havells/ KEI/ Polycab) 381 16 sqmm 382 25 sqmm 383 35 sqmm 384 50 sqmm 385 70 sqmm 386 95 sqmm 387 120 sqmm 388 150 sqmm 389 185 sqmm 390 240 sqmm 391 300 sqmm 392 Providing and fitting of XLPE insulated, 1100V 3.5-core industrial armoured aluminium cable as per IS 7098 (Preferred make: Finolex/ Gloster/ Havells/ KEI/ Polycab) 393 25 sqmm 394 35 sqmm 395 50 sqmm 396 70 sqmm 397 95 sqmm 398 120 sqmm 399 150 sqmm 400 185 sqmm 401 240 sqmm 402 300 sqmm 403 Providing and installation of SPN sheet steel enclosed Distribution boxes - Single door (Make: L&T/ Legrand/ Hager/ Havells/ Benlo) 404 4 way 405 8 way 406 12 way 407 16 way 408 Providing and installation of ‘B’ Series MCB 240V, 50Hz, 10kA Suitable for lighting and other domestic loads (Preferred Make: L&T/ Legrand/ Hager/ Havells/ Schneider) 409 6-32A SP 410 40A SP 411 6-32A DP 412 40A DP 413 100A 4P isolator 414 Providing and installation of Change over switches of metal enclosure 240v 50Hz (Preferred make: Anchor/ SSK/ Havells/ L&T) 415 2-pole 16A 415V 416 2-pole 32A 415V 417 4-pole 32A 415V 418 4-pole 63A 415V 419 4-pole 100A 415V 420 Providing and installation of Busbar chamber 3-ph 4 bar heavy duty copper strips with rating as under(Preferred make: Havells/ SSK/ L&T) 421 63A 415V 422 100A 415V 423 200A 415V 424 MANPOWER 425 Hiring charges of Electrician (for troubleshooting/ revamping of existing electrical fitting, etc. exclusive of specified works): 426 Hiring charges of Labourer for support of electrician 427 Excavating trenches of required width for pipes, cables, etc in all kinds of soil including excavation for sockets and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m 428 Pipes, cables etc, not exceeding 80 mm dia. 429 Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia 430 Pipes, cables etc. exceeding 300 mm dia but not exceeding 600 mm dia 431 Pipes, cables etc. exceeding 600 mm dia but not exceeding 1200 mm dia 432 Extra for excavating trenches for pipes, cables etc. in all kinds of soil for depth exceeding 1.5 m, but not exceeding 3m. (Rate is over corresponding basic item for depth upto 1.5 metre). 433 Extra for excavating trenches for pipes, cables, etc, in all kinds of soil for depth exceeding 3 m in depth, but not exceeding 4.5 m. (Rate is over corresponding basic item for depth upto 1.5 metre.)
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 5
Jammu And Kashmir View Result →
30.
Health and Family Welfare #10284420 Price Bid
Fixing Of Rate Contract For Repairs / Replacement To Electrical Equipment Installed At Different Wsss Of Phe Mechanical Sub-Division Qazigund ( District Anantnag And Kulgam ) For The Financial Year 2023-24- 1 Mechanical Transportation, Loading, Unloading And Handling Of Various Items Such As Pump Parts, Motors, Starters, Voltage Stabilizers, Coil Assemblies, Welding Tools & Plant, Etc. Using Appropriate Means Of Transport As Under: 2 Private Car, Auto-Rickshaw Or Similar With 1.0 Km Lead 3 Extra Per Kilometer For Lead >1.0 Kms Upto 5.0 Kms 4 Extra Per Kilometer For Lead >5.0 Kms Upto 10.0 Kms 5 Extra Per Kilometer For Lead >10.0 Kms Upto 20.0 Kms 6 Extra Per Kilometer For Lead >20.0 Kms Upto 30.0 Kms 7 Load Carrier Auto, Mini Van Or Similar With 1.0 Km Lead 8 Extra Per Kilometer For Lead >1.0 Kms Upto 5.0 Kms 9 Extra Per Kilometer For Lead >5.0 Kms Upto 10.0 Kms 10 Extra Per Kilometer For Lead >10.0 Kms Upto 20.0 Kms 11 Extra Per Kilometer For Lead >20.0 Kms Upto 30.0 Kms 12 Mini Truck Like Tata Mobile, Bolero Camper Or Similar With 1.0 Km Lead 13 Extra Per Kilometer For Lead >1.0 Kms Upto 5.0 Kms 14 Extra Per Kilometer For Lead >5.0 Kms Upto 10.0 Kms 15 Extra Per Kilometer For Lead >10.0 Kms Upto 20.0 Kms 16 Extra Per Kilometer For Lead >20.0 Kms Upto 30.0 Kms 17 Voltage Stabilizersdismantling Of 415V 3-Ph Voltage Stabilizer By Way Of Opening Of Top Lid, Disassembling Of Voltage Regulator, Removing Of All Incoming And Outgoing Connections, Taking Out Of Damaged Copper Legs After Removal Of Core, Etc. The Job Includes Draining Out Of T. Oil And Its Safe Placement For Further Refilling. 18 Upto 50 Kva 19 >50 Upto 100Kva 20 >100Kva Upto 250 Kva 21 Greater Than 250 Kva 22 Assembling Of All Parts Of 3-Ph Voltage Stabilizer, Connecting Of Leads Of All Incoming And Outgoing Connections And Refilling Of Old Drained Out Of T. Oil 23 Upto 50 Kva 24 >50 Upto 100Kva 25 >100Kva Upto 250 Kva 26 Greater Than 250 Kva 27 Isolating And Disconnecting Of All Incoming And Outgoing Leads From Autotransformer Starter. Draining Out Transformer Oil From The Oil Tank And Collecting In A Suitable Vessel. Taking Out The Damaged Autotransformer Coil Assembly From Oil Tank. 28 >60 Upto 200 Hp 29 Providing Of Transformer Oil Conforming To Is 335 ( Preferred Make: Power Oil / Indian Oil Servo / Hpcl ) 30 Filtration Of Existing / Reclaimed T-Oil At Suitable Temperature ( Inclusive Of All Logistics And Charges For Filtration Plant, Etc ) ( Process Loss Maximum Of 5% Allowed ) 31 Rewinding Burnt / Damaged Windings Of Voltage Stabilizer Coil Assembly ( Comprising Of Three Limbs ) Using Superior Quality Copper Wire Of Proper Gauge As Per Requirement With Superior Insulation. ( Note: The Unserviceable Scrap Copper Generated Shall Be Property Of The Firm And Is Taken Into Account For Estimation Of Rates ) . 32 10Kva Rating 33 30Kva Rating 34 50Kva Rating 35 75Kva Rating 36 100Kva Rating 37 150Kva Rating 38 175Kva Rating 39 200Kva Rating 40 250Kva Rating 41 Removing Of Damagedplate Type Voltage Regulator Switch From 3 Phase , 415 ±15 % Volt Voltage Stabilizer And Providing And Fitting Of New Plate Type Voltage Regulator Switch Having Copper Contact Points With 6 Steps. The Job Includes Cost On Account Of Skilled / Semi-Skilled Labour Required For Work 42 10Kva Rating 43 30Kva Rating 44 50Kva Rating 45 75Kva Rating 46 100Kva Rating 47 150Kva Rating 48 175Kva Rating 49 200Kva Rating 50 250Kva Rating 51 Impregnation / Heat Treatment Ofwinding Assembly Of 3 Phase, 415 ±15 % Volt Voltage Stabilizerby Way Of Keeping It In An Electric Oven For About 24 Hours And At Approperate Temperature. 52 10Kva Rating 53 30Kva Rating 54 50Kva Rating 55 75Kva Rating 56 100Kva Rating 57 150Kva Rating 58 175Kva Rating 59 200Kva Rating 60 250Kva Rating 61 Removing Of Damaged Copper Connection Terminal Bolt With Washer And Nut From3 Phase, 415 ±15 % Volt Voltage Stabilizer And Providing And Fitting Of New Copper Connection Terminal Bolt With Nut And Washer. 62 10Kva Rating 63 30Kva Rating 64 50Kva Rating 65 75Kva Rating 66 100Kva Rating 67 150Kva Rating 68 175Kva Rating 69 200Kva Rating 70 250Kva Rating 71 500Kva Rating 72 Hiring Of Portable Welding Set / Soldering Equipment Etc. Excluding Power Charges 73 Arresting Of Leakage In, 3 Phase , 415 ±15 % Volt Voltage Stabilizer Tank Along With Radiator Fins / Tubesby Way Of Soldering / Welding At The Cracked Spot ( Average Length Of Spot = 1 Inch ) 74 Providing And Replacement Of Copper Contact Points On Regulator Plate 75 Providing And Fitting Of Lv Copper Terminal Connectors With Allied Insulation _ ( For Finished Weight Of The Connector ) 76 Starterisolating And Disconnecting Of All Incoming And Outgoing Leads From Autotransformer Starter. Draining Out Transformer Oil From The Oil Tank And Collecting In A Suitable Vessel. Taking Out The Damaged Autotransformer Coil Assembly From Oil Tank. 77 Upto 60 Hp Rating 78 >60 Upto 200 Hp 79 >200 Hp Upto 350 Hp 80 Greater Than 350 Hp 81 Fitting Of Autotransformer Coil Assembly In The Starter Oil Tank, Filling Of T.Oil In The Tank, Connecting All Leads And Load Testing Of The Starter. 82 Upto 60 Hp Rating 83 >60 Upto 200 Hp 84 >200 Hp Upto 350 Hp 85 Greater Than 350 Hp 86 Contactorsproviding And Fitting Of 3-Pole Contactor ( Ac-3 Duty ) With Specified Coil Voltage: 87 L&T Ml 1.5 88 L&T Ml 2 89 L&T Ml 3 90 L&T Ml 4 91 L&T Ml 6 92 L&T Ml 12 93 L&T Mnx 50 94 L&T Mnx 70 95 L&T Mnx 80 96 L&T Mnx 95 97 L&T Mnx 110 98 L&T Mnx 140 99 L&T Mnx 185 100 L&T Mnx 225 101 L&T Mnx 250 102 Mk1 103 Mk2 104 Mu1 105 Mu1h 106 Mu2 107 Mu3 108 Ml2w 109 Ml3w 110 Ml4w 111 Ml6w 112 Schneider Electric Lc1f265 ( Without Coil ) 113 Schneider Electric Lc1f330 ( Without Coil ) 114 Schneider Electric Lc1f400 ( Without Coil ) 115 Schneider Electric Lc1f630 ( Without Coil ) 116 32A Ac-3 Rating ( Siemens 3Tf / L&T Type Mo / Schneider ) 117 45A Ac-3 Rating With 2No + 2Nc Auxillary Contacts ( Siemens 3Tf / L&T Type Mo / Schneider ) 118 Providing And Fitting Of New Ac Coil With Specified Coil Voltage For Contactors: 119 9A To 45A Ac-3 Rating ( Siemens 3Tf / Equivalent ) 120 L&T Ml 2 / 3 121 L&T Ml 4 / 6 122 L&T Ml 10 / 12 123 L&T Mnx 50 / 70 / 80 124 L&T Mnx 95 / 110 / 140 125 L&T Mnx 185 / 225 / 250 126 L&T Mnx 300 / 400 127 L&T Mnx 550 / 650 128 Schneider Electric Lc1f185 / Lc1f225 129 Schneider Electric Lc1f265 / Lc1f330 130 Schneider Electric Lc1f400 131 Schneider Electric Lc1f630 132 Providing And Fitting Of New Contact Kit Set For Contactors 133 32A Ac-3 Rating ( Siemens 3Tf / Equivalent ) 134 L&T Ml 2 135 L&T Ml 3 136 L&T Ml 4 137 L&T Ml 6 138 L&T Ml 10 139 L&T Ml 12 140 Providing And Fitting Of Auxillary Contactors / Control Relay 141 L&T Mx0 Having 04 Contacts ( All Combinations ) For Ac Control 142 L&T Mx0 Having 04 Contacts ( All Combinations ) For Dc Control 143 L&T Ml ( 1No+1Nc ) Side Mounting Auxillary Contact Block 144 L&T Mnx / Mcx Front Mounting Type Having 04 Contacts ( All Combinations ) 145 Timing Relaysproviding, Fitting And Setting Up Of Single Range Auto Reset Synchronous On Delay Timer ( L&T Or Equivalent Make ) 146 Providing, Fitting And Setting Of Electropneumatic Timing Relay With Timing Range Upto 60S; Coil Voltage 415V Ac ( Bch Or Equivalent Make ) . 147 ( 2No + 2Nc ) Double Block; On Delay 148 ( 2No + 2Nc ) Double Block; On & Off Delay 149 Providing And Fitting Of Spares For Electropneumatic Timing Relay ( Bch Make Or Equivalent ) 150 ( 2No + 2Nc ) Contact Block 151 Magnetic Coil 415V Ac 152 Magnet Frame Assembly Without Coil 153 Providing, Fitting And Setting Of Din Mounted Electronic Timer ( L&T Gic Or Equivalent Make ) 154 Star Delta ( Range From 3S - 120S ) 240V Ac 155 Star Delta ( Range From 3S - 30S ) 240 - 415V Ac 156 On Delay ( 0.3S - 30Hrs ) 240V Ac 157 Thermal Overload Relayproviding, Fitting And Setting Of Thermal Overload Relay Of Specified Relay Range ( Make: L&T Mn2 ) 158 Relay Range In Between 0.2A To 15A 159 14-23A 160 20-33A 161 24-40A 162 Providing, Fitting And Setting Of Thermal Overload Relay Of Specified Relay Range ( Make: L&T Mn5 ) 163 20-33A 164 30-50A 165 36-60A 166 45-75A 167 66-110A 168 Providing, Fitting And Setting Of Thermal Overload Relay Of Specified Relay Range 169 L&T Ml1 ( Relay Range In Between 0.15A To 16A ) 170 L&T Ml2 / 3 ( Relay Ranges In Between 9A To 42A ) 171 Miscellaneous 172 Providing And Fitting Of Bakelite Connection Plate Minimum 10Mm Thick As Per Given Size For Autotransformer With Holes For Connection Studs Drilled At Requisite Spots 173 Complete Servicing Of Control Wiring Of Ats Including Checking, Tightening Of Connections, Tapping And Insulation As Per Requirement. 174 Complete Replacement Of Suitable Copper Control Wiring Of Ats Including Cable Ties, Connections, Tapping And Insulation As Per Requirement. 175 Oil Immersed Starter Sparesproviding And Replacement Of Operating Coil For Oil Immersed Semi-Automatic Starter, Upto 40Hp 176 Providing And Fitting Of Heavy Duty Contact Kit Set For Semi-Automatic / Fully Automatic Sd Oil Immersed Starters ( Set Of 03 Moving And 06 Stationary Contacts ) , Upto 40 Hp 177 Spares For Oil Immersed Manual Starters 178 Fixed Finger Contact 179 Moving Tip Contact 180 No Volt Coil 181 Moving Drum Contact ( Starters Upto 40Hp ) 182 Moving Drum Contact ( Starters > 40Hp ) 183 Base Plate Bakelite / Dmc ( Starters Upto 40Hp ) 184 Base Plate Bakelite / Dmc ( Starters > 40Hp ) 185 Steam Carrier Assembly ( Starters Upto 40Hp ) 186 Steam Carrier Assembly ( Starters > 40Hp ) 187 Sequence Shaft ( Starters Upto 40Hp ) 188 Sequence Shaft ( Starters > 40Hp ) 189 Bakelite Tube For Sequence Shaft ( Starters Upto 40Hp ) 190 Bakelite Tube For Sequence Shaft ( Starters > 40Hp ) 191 Trip Rod Assembly ( Starters Upto 40Hp ) 192 Trip Rod Assembly ( Starters > 40Hp ) 193 Lock Lever 194 Cam Assembly 195 Oil Dashpot Assembly 196 Overload Coil ( Set Of 03 Nos. ) Upto 20Hp 197 Overload Coil ( Set Of 03 Nos. ) 30- 40Hp 198 Overload Coil ( Set Of 03 Nos. ) 50- 60Hp 199 Overload Coil ( Set Of 03 Nos. ) 70- 80Hp 200 Overload Coil ( Set Of 03 Nos. ) 90- 100Hp 201 L&T Mu-G Submersible Pump Controller Sparesvolt-Ammeter 500V, 202 Electronic Star-Delta Timer 3-30S 203 Providing And Fitting Of Terminal Block 204 60A - 3 Way 205 100A - 3 Way 206 Single Phase Preventing Relay Sz5 Type 207 Single Phase Preventing Relay Sdz5 Type 208 Providing, Fitting And Setting Of Thermal Overload Relay Of Specified Relay Range ( Make: L&T ) 209 Mk1 ( All Ranges ) 210 Mu1 ( All Ranges ) 211 Mu2 Relays Of Following Ranges 212 6 -10 A, 9 - 14A 213 13 - 21A 214 15 - 25A 215 20 - 32A 216 24 - 38A 217 28 - 42A 218 Providing And Fitting Of Standard Operating Coil For Following Contactors 219 Mk1 / Mk2 220 Mu1 / Mu2 / Mu3 221 Providing And Fitting Of Contact Bridge Without Contact Of Following Contactors 222 Mk1 / Mk2 223 Mu1 / Mu2 / Mu3 224 Providing And Fitting Of Single Moving Contact Of Following Contactors 225 Mk1 226 Mk2 227 Mu1 228 Mu2 229 Mu3 230 Indicating Lamps 231 Rocker Switch 232 Rocker Switch ( Mug-G6 To Mug G20 ) 233 Rocker Switch ( Mug-G30 To Mug G75 ) 234 Voltage Selector Switch 235 30A Ammeter Spare For Mr-G Controller 236 Volt Ammeter ( 30A, 300V Ac ) For 3-30 Sec Or 12-20 Sec. 237 Electronic Star -Delta Timer For Mug Starters 238 Electronic Star -Delta Timer Type St100, 160 - 500V, For 3-30 Sec Or 12-20 Sec. 239 Providing And Fitting Of Mu Coil 240 / 360 / 415 V To Mug Submersible Starter 240 Providing And Fitting Of Mu1 / Mu1h / Mu2 / Mu3 Contact Bridge 241 Providing And Fitting Of Mu1 / Mu2 Relay Extension Job To Mug Submersible Starter 242 Providing And Fitting Of Mu1 / M, U1h / Mu2 / Mu3housing To Mug Submersible Starter 243 Providingand Fitting Of New Mug After Removing Old Damaged Ones 244 Mug 6, 6-10 Amp Relay 245 Mug 6, 9-14 Amp Relay 246 Mug 10, 13-21 Amp Relay 247 Mug 10, 20-32 Amp Relay 248 Mug 10, 28-42 Amp Relay 249 Mug 15, 11-18 Amp Relay 250 Mug 15, 13-22 Amp Relay 251 Mug 20, 9-14 Amp Relay 252 Mug 20H, 20-32 Amp Relay 253 Mug 20H, 28-42 Amp Relay 254 Mug 30, 20-33 Amp Relay 255 Mug 30, 30-50 Amp Relay 256 Mug 40, 30-50 Amp Relay 257 Mug 40, 36-60 Amp Relay 258 Mug 50, 36-50 Amp Relay 259 Mug 50, 45-75 Amp Relay 260 Mug 75, 45-75 Amp Relay 261 Mug 75, 66-110 Amp Relay 262 Mccbproviding And Fitting Of 3-Pole 415V Mccb With Thermal Magnetic Release Having 36Ka Breaking Capacity ( Ics= 100% Icu ) ( Make: L&T D-Sine Or Equivalent ) Having Max. Of Thermal Release Range As Under: 263 Upto And Including 100A ( Ics= 50% Icu ) 264 125A 265 160A 266 200A 267 250A 268 400A 269 Providing And Fitting Of 3-Pole 415V Mccb With Thermal Magnetic Release Having 50Ka Breaking Capacity Ics = 100% Icu ( Make: L&T D-Sine Or Equivalent ) Having Max. Of Thermal Release Range As Under: 270 125A 271 160A 272 200A 273 250A 274 400A 275 630A 276 Providing Of Set Of Spreader Terminals For Above 3-Pole Mccbs 277 100A 278 125A 279 250A 280 400A 281 630A 282 Providing And Fitting Of 4-Pole 415V Mccb With Thermal Magnetic Release Having 50Ka Breaking Capacity Ics = 100% Icu ( Make: L&T D-Sine Or Similar ) Having Max. Of Thermal Release Range As Under: 283 125A 284 160A 285 200A 286 250A 287 400A 288 630A 289 Spares For Acb ( L&T C-Power ) Providing And Fitting Of Pole Assembly For Draw Out Type Acb ( L&T C-Power ) 290 Upto 1250A 291 2000A 292 Providing And Fitting Of Arc Chute ( 440V ) For Acb ( L&T C-Power ) 293 Upto 1250A 294 1600 - 2000A 295 Providing And Fitting Of Jaw Contact For Acb ( L&T C-Power ) 296 630-1000A 297 1250A 298 1600A / 2000A 299 Providing And Fitting Of Fixed Arcing Contact For Acb ( L&T C-Power ) 300 800- 1600A 301 2000A 302 Providing And Fitting Of Moving Arcing Contact For Acb ( L&T C-Power ) 303 800- 2000A 304 Providing And Fitting Of Shunt Release For Acb ( L&T C-Power ) 305 Providing And Fitting Of Under Voltage Release For Acb ( L&T C-Power ) 306 Providing And Fitting Of Moving Arcing Contact For Acb ( L&T C-Power ) 307 Providing And Fitting Of Terminal Adaptor For Draw Out L&T C-Power Acb Of Ratings As Under: 308 Upto 800 - 1250A 309 1600 - 2000A 310 Providing And Fitting Of Thermal-Magnetic Release ( Type Dn1 ) For L&T C-Power Acb 311 Providing And Fitting Of Ct For Dn1 Type L&T C-Power Acb 312 800 / 1000A 313 1250 / 1600A 314 2000A 315 Providing And Fitting Of Main Spring For 3-Pole Acb ( L&T C-Power ) 316 800- 1600A 317 2000A 318 Providing Of Racking Handle For Draw-Out Type Acbs ( L&T C-Power ) Rating Upto 2000A 319 Providing And Replacement Of Spring Charging Motor ( Ac / Dc ) 320 Providing And Replacement Of Motor Limit Switch 321 Instrumentation And Panel Accessoriesproviding And Fitting Of 96X96 Flush Mounting 3-Phase Led Ammeter / Voltmeter Of Class 1 Accuracy ( Make: L&T / Schneider / Rishabh / Ae ) 322 Providing And Fitting Of Flush Type Analog Moving Iron Ac Meter As Under: ( Make: Rishabh / Ae / C&S / Bch ) 323 48X48mm 500V Voltmeter 324 96X96mm 500V Voltmeter 325 144X144mm 500V Voltmeter 326 96X96mm Ammeter ( 5A Ct Operated ) 327 Providing And Fitting Of Flush Type Frequency Meter With Range 45-55Hz: ( Make: Rishabh / Ae / L&T / Schneider / Bch ) 328 Providing And Fitting Of 10A Line Current Ammeter Selector Switch With Off ( Make: L&T / Rishabh / Ae / Teknic ) 329 Providing And Fitting Of 10A Voltmeter Selector Switch With Off ( Make: L&T / Rishabh / Ae / Teknic ) 330 Providing And Fitting Of Tape Insulated Ring Type Metering Current Transformers ( Ae / Rishabh / Crompton / Kilburn ) As Under: 331 100 / 5A Or 150 / 5A - Class 1 - Burden 5Va 332 200 / 5A - Class 1 - Burden 10Va 333 400 / 5A - Class 1 - Burden 15Va 334 600 / 5A - Class 1 - Burden 15Va 335 800 / 5A - Class 1 - Burden 15Va 336 1000 / 5A - Class 1 - Burden 15Va 337 2000 / 5A - Class 1 - Burden 15Va 338 Extra For 1A Secondary Upto 600 / 1A Over Corresponding Rate 339 Providing And Fitting Of Analog Vac Hour Meter ( Make: L&T Or Equivalent Make ) 340 Din Mounting Type 341 Flush Mounting Type 342 Providing And Fitting Of Flush Or Projecting Head Push Button With Contact Block ( L&T / Teknic / Abb / Bch / Schneider Or Any Other Reputed Make ) 343 Providing And Fitting Of Led Phase Indicator With Surge Protection ( L&T / Teknic / Abb / Bch / Schneider Or Any Other Reputed Make ) 344 Providing And Fitting 3 Phase, 3 / 4 Wire Adjustable Under & Over Voltage Monitoring Relay ( Minilec Vct D2 Or Equivalent ) 345 Providing, Fitting And Setting Of 415V Auto Reset Single Phase Preventor ( L&T / Minilec / Bch Or Equivalent Make ) 346 50V Or Less Unbalance & 1 C / Odin Mounted 347 50V Or Less Unbalance & 1 C / Opanel Wall Mounted 348 70V Or Less Unbalance & 2 C / Odin Mounted 349 Providing And Fitting Of 32A Dp Switch ( Anchor / Ssk Or Any Other Reputed Make ) 350 Providing Of Hrc Fuses ( 2A - 32A ) Ratings 351 Providing And Fitting Of Fuse Holders For Fuses Upto 32A Rating 352 Providing And Fixing Upvc Panel Trunking With Cover 353 15X15mm 354 25X25mm 355 Terminals / Lugsproviding And Crimping Of Various Aluminium Tube Lugs ( Dowells / Action / Or Any Other Reputed Make ) With Tapping, Insulation As Under: 356 16 Sq. Mm 357 25 Sq. Mm 358 35 Sq. Mm 359 50 Sq. Mm 360 70 Sq. Mm 361 95 Sq. Mm 362 120 Sq. Mm 363 150 Sq. Mm 364 185 Sq. Mm 365 225 Sq. Mm 366 240 Sq. Mm 367 300 Sq. Mm 368 Providing And Crimping Of Various Copper Tube Lugs ( Dowells / Action / Or Any Other Reputed Make ) With Tapping, Insulation As Under: 369 16 Sq. Mm 370 25 Sq. Mm 371 35 Sq. Mm 372 50 Sq. Mm 373 70 Sq. Mm 374 95 Sq. Mm 375 120 Sq. Mm 376 150 Sq. Mm 377 185 Sq. Mm 378 225 Sq. Mm 379 240 Sq. Mm 380 300 Sq. Mm 381 Cablesproviding And Fitting Of Pvc Insulated 1100V Flat 3-Core Industrial Copper Cable For Submersible Pump Motors ( Preferred Makes: Finolex / L&T / Havells / Kei / Polycab ) 382 1.5 Sqmm 383 2.5 Sqmm 384 4.0 Sqmm 385 6.0 Sqmm 386 10.0 Sqmm 387 16.0 Sqmm 388 25.0 Sqmm 389 35.0 Sqmm 390 Providing And Fitting Of Xlpe Insulated, 1100V Single Core Armoured Industrial Copper Cable As Under ( Preferred Make: Finolex / Gloster / Havells / Kei / Polycab ) 391 16.0 Sqmm 392 25 Sqmm 393 35 Sqmm 394 50 Sqmm 395 70 Sqmm 396 95 Sqmm 397 120 Sqmm 398 150 Sqmm 399 185 Sqmm 400 240 Sqmm 401 300 Sqmm 402 400 Sqmm 403 Providing And Fitting Of Xlpe Insulated, 1100V Single Core Industrial Armoured Aluminium Cable As Under ( Preferred Make: Finolex / Gloster / Havells / Kei / Polycab ) 404 16 Sqmm 405 25 Sqmm 406 35 Sqmm 407 50 Sqmm 408 70 Sqmm 409 95 Sqmm 410 120 Sqmm 411 150 Sqmm 412 185 Sqmm 413 240 Sqmm 414 300 Sqmm 415 Providing And Fitting Of Xlpe Insulated, 1100V 3.5-Core Industrial Armoured Aluminium Cable As Per Is 7098 ( Preferred Make: Finolex / Gloster / Havells / Kei / Polycab ) 416 25 Sqmm 417 35 Sqmm 418 50 Sqmm 419 70 Sqmm 420 95 Sqmm 421 120 Sqmm 422 150 Sqmm 423 185 Sqmm 424 240 Sqmm 425 300 Sqmm 426 Wiringproviding And Fitting Of Pvc Insulated 1100V Flexible Copper Cable ( Frls ) For Electrical Installations As Under ( Preferred Makes: Finolex / Anchor / L&T / Havells / Kei / Polycab ) 427 1.0 Sqmm 428 1.5 Sqmm 429 2.5 Sqmm 430 4.0 Sqmm 431 6.0 Sqmm 432 10.0 Sqmm 433 16.0 Sqmm 434 2X1.5 Sqmm 435 2X2.5 Sqmm 436 2X6 Sqmm ( Aluminium Unarmoured ) 437 Conduits 438 Providing And Fixing 25Mm Pvc Round Conduit ( Medium ) With Allied Pvc Fittings 439 Providing And Fixing Upvc Trunking 25X16mm With Allied Fittings 440 Providing And Fixing Polypropylene Corrugated Flexible Conduit 441 25Mm 442 32Mm 443 Providing And Fitting Perforated Ms Cable Trays Including Horizontal And Vertical Bends, Reducers, Tees, Cross Members And Other Accessories As Required And Duly Suspended From The Ceiling With Ms Suspenders Or Fixing On Cantilever Supports And Including Painting Etc As Required. 444 100 X 50 X 1.6Mm 445 150 X 50 X 1.6Mm 446 Electrical Fitingsproviding And Fitting Of Various Electrical Fittings As Under ( Preferred Makes: Anchor / Ssk / Havells ) 447 Switch-6A-Sp-1Way, 240V, 50 Hz, Ac. 448 Switch-6A-Sp-2Way, 240V, 50 Hz, Ac. 449 Cord Switches:- Providing And Fitting Of Cord Switch-6A-Sp-1Way, 240V, 50 Hz, Ac / Hanging Bell Push. 450 Bell Push 240V, 50 Hz, Ac. 451 6A Socket:- Providing And Fitting Of6a-2 / 3 Pin-Universal Socket, 240V, 50 Hz, Ac. 452 Neon Indicator 453 Mini Telephone Jack 454 Fan Regulator ( Mini ) With Rotary Step 455 Fan Regulator ( Deluxe ) With Rotary Step 456 Shuttered-3 Pin Socket And Switch ( Box / Recessed ) - 20A-Sp-1 Way, 230V 50 Hz, Ac. 457 Plug Top 15 / 16A 3 Pin ( Isi Marked ) 458 32A Tp Switch 415V With Neon 459 32A Dp Switch 240V With Neon 460 Surface Mounting Box For Switches As Follows: 461 1 Gang Box 462 2 Gang Box 463 3 Gang Box 464 4 Gang Box 465 5 Gang Box 466 6 Gang Box 467 7 Gang Box 468 4 Gang Box ( Double Domestic ) 469 Providing, Fixing, Testing Of 6A Ceiling Rose 470 Providing And Installation Of Pendant / Angle / Batten Holders 6A 240V 471 Providing And Installation Of Spn Sheet Steel Enclosed Distribution Boxes - Single Door ( Make: L&T / Legrand / Hager / Havells / Benlo ) 472 4 Way 473 8 Way 474 12 Way 475 16 Way 476 Providing And Installation Of ‘B’ Series Mcb 240V, 50Hz, 10Ka Suitable For Lighting And Other Domestic Loads ( Preferred Make: L&T / Legrand / Hager / Havells / Schneider ) 477 6-32A Sp 478 40A Sp 479 6-32A Dp 480 40A Dp 481 100A 4P Isolator 482 Providing And Installation Of Change Over Switches Of Metal Enclosure 240V 50Hz ( Preferred Make: Anchor / Ssk / Havells / L&T ) 483 2-Pole 16A 415V 484 2-Pole 32A 415V 485 4-Pole 32A 415V 486 4-Pole 63A 415V 487 4-Pole 100A 415V 488 Providing And Installation Of Busbar Chamber 3-Ph 4 Bar Heavy Duty Copper Strips With Rating As Under ( Preferred Make: Havells / Ssk / L&T ) 489 63A 415V 490 100A 415V 491 200A 415V 492 Manpower 493 Hiring Charges Of Electrician ( For Troubleshooting / Revamping Of Existing Electrical Fitting, Etc. Exclusive Of Specified Works ) : 494 Hiring Charges Of Labourer For Support Of Electrician 495 Excavating Trenches Of Required Width For Pipes, Cables, Etc In All Kinds Of Soil Including Excavation For Sockets And Dressing Of Sides, Ramming Of Bottoms, Depth Upto 1.5 M, Including Getting Out The Excavated Soil, And Then Returning The Soil As Required, In Layers Not Exceeding 20 Cm In Depth, Including Consolidating Each Deposited Layer By Ramming, Watering, Etc. And Disposing Of Surplus Excavated Soil As Directed, Within A Lead Of 50 M 496 Pipes, Cables Etc, Not Exceeding 80 Mm Dia. 497 Pipes, Cables Etc. Exceeding 80 Mm Dia. But Not Exceeding 300 Mm Dia 498 Pipes, Cables Etc. Exceeding 300 Mm Dia But Not Exceeding 600 Mm Dia 499 Pipes, Cables Etc. Exceeding 600 Mm Dia But Not Exceeding 1200 Mm Dia 500 Extra For Excavating Trenches For Pipes, Cables Etc. In All Kinds Of Soil For Depth Exceeding 1.5 M, But Not Exceeding 3M. ( Rate Is Over Corresponding Basic Item For Depth Upto 1.5 Metre ) . 501 Extra For Excavating Trenches For Pipes, Cables, Etc, In All Kinds Of Soil For Depth Exceeding 3 M In Depth, But Not Exceeding 4.5 M. ( Rate Is Over Corresponding Basic Item For Depth Upto 1.5 Metre. )
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 4
Jammu And Kashmir View Result →
31.
Drinking Water Supply and Sanitation #10284418 Price Bid
Fixing Of Rate Contract For Repairs/ Replacement To Electrical Equipment Installed At Different Wsss Of Phe Mechanical Sub-Division Shopian (District Pulwama And Shopian) For The Financial Year 2023-24- 1 Mechanical transportation, loading, unloading and handling of various items such as pump parts, motors, starters, voltage stabilizers, coil assemblies, welding tools & plant, etc. using appropriate means of transport as under: 2 Private car, auto-rickshaw or similar with 1.0 km lead 3 Extra per kilometer for lead >1.0 kms upto 5.0 kms 4 Extra per kilometer for lead >5.0 kms upto 10.0 kms 5 Extra per kilometer for lead >10.0 kms upto 20.0 kms 6 Extra per kilometer for lead >20.0 kms upto 30.0 kms 7 Load carrier auto, mini van or similar with 1.0 km lead 8 Extra per kilometer for lead >1.0 kms upto 5.0 kms 9 Extra per kilometer for lead >5.0 kms upto 10.0 kms 10 Extra per kilometer for lead >10.0 kms upto 20.0 kms 11 Extra per kilometer for lead >20.0 kms upto 30.0 kms 12 Mini truck like Tata mobile, Bolero Camper or similar with 1.0 km lead 13 Extra per kilometer for lead >1.0 kms upto 5.0 kms 14 Extra per kilometer for lead >5.0 kms upto 10.0 kms 15 Extra per kilometer for lead >10.0 kms upto 20.0 kms 16 Extra per kilometer for lead >20.0 kms upto 30.0 kms 17 VOLTAGE STABILIZERSDismantling of 415V 3-ph Voltage Stabilizer by way of opening of top lid, disassembling of voltage regulator, removing of all incoming and outgoing connections, taking out of damaged copper legs after removal of core, etc. The job includes draining out of T. Oil and its safe placement for further refilling. 18 upto 50 kVA 19 >50 upto 100kVA 20 >100kVA upto 250 kVA 21 Greater than 250 kVA 22 Assembling of all parts of 3-ph Voltage Stabilizer, connecting of leads of all incoming and outgoing connections and refilling of old drained out of T. Oil 23 upto 50 kVA 24 >50 upto 100kVA 25 >100kVA upto 250 kVA 26 Greater than 250 kVA 27 Isolating and disconnecting of all incoming and outgoing leads from autotransformer starter. Draining out transformer oil from the oil tank and collecting in a suitable vessel. Taking out the damaged autotransformer coil assembly from oil tank. 28 >60 upto 200 HP 29 Providing of transformer oil conforming to IS 335 (Preferred make: Power oil/ Indian Oil Servo/ HPCL) 30 Filtration of existing/ reclaimed T-oil at suitable temperature (inclusive of all logistics and charges for filtration plant, etc)(Process loss maximum of 5% allowed) 31 Rewinding burnt/ damaged windings of voltage stabilizer coil assembly (comprising of three limbs) using superior quality copper wire of proper gauge as per requirement with superior insulation. (Note: The unserviceable scrap copper generated shall be property of the firm and is taken into account for estimation of rates). 32 10kVA rating 33 30kVA rating 34 50kVA rating 35 75kVA rating 36 100kVA rating 37 150kVA rating 38 175kVA rating 39 200kVA rating 40 250kVA rating 41 Removing of damagedplate type voltage regulator switch from 3 phase , 415 ±15 % Volt voltage stabilizer and providing and fitting of new plate type voltage regulator switch having copper contact points with 6 steps. the job includes cost on account of skilled/semi-skilled labour required for work 42 10kVA rating 43 30kVA rating 44 50kVA rating 45 75kVA rating 46 100kVA rating 47 150kVA rating 48 175kVA rating 49 200kVA rating 50 250kVA rating 51 Impregnation/heat treatment ofwinding assembly of 3 phase, 415 ±15 % Volt voltage stabilizerby way of keeping it in an electric oven for about 24 hours and at approperate temperature. 52 10kVA rating 53 30kVA rating 54 50kVA rating 55 75kVA rating 56 100kVA rating 57 150kVA rating 58 175kVA rating 59 200kVA rating 60 250kVA rating 61 Removing of damaged copper connection terminal bolt with washer and nut from3 phase, 415 ±15 % Volt voltage stabilizer and providing and fitting of new copper connection terminal bolt with nut and washer. 62 10kVA rating 63 30kVA rating 64 50kVA rating 65 75kVA rating 66 100kVA rating 67 150kVA rating 68 175kVA rating 69 200kVA rating 70 250kVA rating 71 500kVA rating 72 Hiring of portable welding set /soldering equipment etc. excluding power charges 73 Arresting of leakage in, 3 phase , 415 ±15 % Volt voltage stabilizer tank along with radiator fins/tubesby way of soldering/ welding at the cracked spot (average length of spot = 1 inch) 74 Providing and replacement of copper contact points on regulator plate 75 Providing and Fitting of LV copper terminal connectors with allied insulation _ (for finished weight of the connector) 76 STARTERIsolating and disconnecting of all incoming and outgoing leads from autotransformer starter. Draining out transformer oil from the oil tank and collecting in a suitable vessel. Taking out the damaged autotransformer coil assembly from oil tank. 77 upto 60 HP rating 78 >60 upto 200 HP 79 >200 HP upto 350 HP 80 greater than 350 HP 81 Fitting of autotransformer coil assembly in the starter oil tank, filling of t.oil in the tank, connecting all leads and load testing of the starter. 82 upto 60 HP rating 83 >60 upto 200 HP 84 >200 HP upto 350 HP 85 greater than 350 HP 86 CONTACTORSProviding and fitting of 3-pole contactor (AC-3 duty) with specified coil voltage: 87 L&T ML 1.5 88 L&T ML 2 89 L&T ML 3 90 L&T ML 4 91 L&T ML 6 92 L&T ML 12 93 L&T MNX 50 94 L&T MNX 70 95 L&T MNX 80 96 L&T MNX 95 97 L&T MNX 110 98 L&T MNX 140 99 L&T MNX 185 100 L&T MNX 225 101 L&T MNX 250 102 MK1 103 MK2 104 MU1 105 MU1H 106 MU2 107 MU3 108 ML2W 109 ML3W 110 ML4W 111 ML6W 112 Schneider Electric LC1F265 (without coil) 113 Schneider Electric LC1F330 (without coil) 114 Schneider Electric LC1F400 (without coil) 115 Schneider Electric LC1F630 (without coil) 116 32A AC-3 rating (Siemens 3TF/ L&T Type MO/ Schneider) 117 45A AC-3 rating with 2NO + 2NC auxillary contacts (Siemens 3TF/ L&T Type MO/ Schneider) 118 Providing and fitting of new AC coil with specified coil voltage for contactors: 119 9A to 45A AC-3 rating (Siemens 3TF/ equivalent) 120 L&T ML 2/ 3 121 L&T ML 4/ 6 122 L&T ML 10/ 12 123 L&T MNX 50/ 70/ 80 124 L&T MNX 95/ 110/ 140 125 L&T MNX 185/ 225/ 250 126 L&T MNX 300/ 400 127 L&T MNX 550/ 650 128 Schneider Electric LC1F185/ LC1F225 129 Schneider Electric LC1F265/ LC1F330 130 Schneider Electric LC1F400 131 Schneider Electric LC1F630 132 Providing and fitting of new Contact kit set for contactors 133 32A AC-3 rating (Siemens 3TF/equivalent) 134 L&T ML 2 135 L&T ML 3 136 L&T ML 4 137 L&T ML 6 138 L&T ML 10 139 L&T ML 12 140 Providing and fitting of auxillary contactors/ control relay 141 L&T MX0 having 04 contacts (all combinations) for AC control 142 L&T MX0 having 04 contacts (all combinations) for DC control 143 L&T ML (1NO+1NC) side mounting auxillary contact block 144 L&T MNX/MCX front mounting type having 04 contacts (all combinations) 145 TIMING RELAYSProviding, fitting and setting up of single range auto reset synchronous ON delay timer (L&T or equivalent make) 146 Providing, fitting and setting of electropneumatic timing relay with timing range upto 60s; coil voltage 415V AC (BCH or equivalent make) . 147 (2NO + 2NC) double block; ON delay 148 (2NO + 2NC) double block; ON & OFF delay 149 Providing and fitting of spares for electropneumatic timing relay (BCH make or equivalent) 150 (2NO + 2NC) contact block 151 Magnetic coil 415V AC 152 Magnet frame assembly without coil 153 Providing, fitting and setting of DIN mounted electronic Timer (L&T GIC or equivalent make) 154 Star Delta (range from 3s - 120s)240V AC 155 Star Delta (range from 3s - 30s)240 - 415V AC 156 ON delay (0.3s - 30hrs) 240V AC 157 THERMAL OVERLOAD RELAYProviding, fitting and setting of thermal overload relay of specified relay range(Make: L&T MN2) 158 Relay range in between 0.2A to 15A 159 14-23A 160 20-33A 161 24-40A 162 Providing, fitting and setting of thermal overload relay of specified relay range(Make: L&T MN5) 163 20-33A 164 30-50A 165 36-60A 166 45-75A 167 66-110A 168 Providing, fitting and setting of thermal overload relay of specified relay range 169 L&T ML1 (Relay range in between 0.15A to 16A) 170 L&T ML2/3 (Relay ranges in between 9A to 42A) 171 MISCELLANEOUS 172 Providing and fitting of bakelite connection plate minimum 10mm thick as per given size for autotransformer with holes for connection studs drilled at requisite spots 173 Complete servicing of control wiring of ATS including checking, tightening of connections, tapping and insulation as per requirement. 174 Complete replacement of suitable copper control wiring of ATS including cable ties, connections, tapping and insulation as per requirement. 175 OIL IMMERSED STARTER SPARESProviding and replacement of operating coil for oil immersed semi-automatic starter, upto 40HP 176 Providing and fitting of heavy duty contact kit set for semi-automatic/ fully automatic SD oil immersed starters (set of 03 moving and 06 stationary contacts), upto 40 HP 177 Spares for oil immersed manual starters 178 Fixed finger contact 179 Moving tip contact 180 No volt coil 181 Moving drum contact (starters upto 40HP) 182 Moving drum contact (starters > 40HP) 183 Base plate Bakelite/ DMC (starters upto 40HP) 184 Base plate Bakelite/ DMC (starters > 40HP) 185 Steam carrier assembly (starters upto 40HP) 186 Steam carrier assembly (starters > 40HP) 187 Sequence shaft (starters upto 40HP) 188 Sequence shaft (starters > 40HP) 189 Bakelite tube for Sequence shaft (starters upto 40HP) 190 Bakelite tube for Sequence shaft (starters > 40HP) 191 Trip rod assembly (starters upto 40HP) 192 Trip rod assembly (starters > 40HP) 193 Lock lever 194 Cam assembly 195 Oil dashpot assembly 196 Overload coil (set of 03 nos.) upto 20HP 197 Overload coil (set of 03 nos.) 30- 40HP 198 Overload coil (set of 03 nos.) 50- 60HP 199 Overload coil (set of 03 nos.) 70- 80HP 200 Overload coil (set of 03 nos.) 90- 100HP 201 L&T MU-G SUBMERSIBLE PUMP CONTROLLER SPARESVolt-Ammeter 500V, 202 Electronic Star-Delta Timer 3-30s 203 Providing and fitting of Terminal Block 204 60A - 3 way 205 100A - 3 way 206 Single phase preventing relay Sz5 type 207 Single phase preventing relay SDz5 type 208 Providing, fitting and setting of thermal overload relay of specified relay range(Make: L&T) 209 MK1 (all ranges) 210 MU1 (all ranges) 211 MU2 relays of following ranges 212 6 -10 A, 9 - 14A 213 13 - 21A 214 15 - 25A 215 20 - 32A 216 24 - 38A 217 28 - 42A 218 Providing and fitting of standard operating coil for following contactors 219 MK1/ MK2 220 MU1/ MU2/ MU3 221 Providing and fitting of contact bridge without contact of following contactors 222 MK1/ MK2 223 MU1/ MU2/ MU3 224 Providing and fitting of single moving contact of following contactors 225 MK1 226 MK2 227 MU1 228 MU2 229 MU3 230 Indicating lamps 231 Rocker switch 232 Rocker switch (MUG-G6 to MUG G20) 233 Rocker switch (MUG-G30 to MUG G75) 234 Voltage Selector switch 235 30A Ammeter Spare for MR-G Controller 236 Volt Ammeter (30A, 300V AC) for 3-30 sec or 12-20 sec. 237 Electronic star -Delta timer for MUG Starters 238 Electronic star -Delta timer type ST100, 160 - 500V, for 3-30 sec or 12-20 sec. 239 Providing and fitting of MU Coil 240/360/415 V to MUG submersible Starter 240 Providing and fitting of MU1/MU1H/MU2/MU3 contact bridge 241 Providing and fitting of MU1/MU2 Relay extension job to MUG submersible starter 242 Providing and fitting of MU1/M,U1H/MU2/MU3housing To MUG submersible starter 243 Providingand fitting of New MUG after removing old damaged ones 244 MUG 6, 6-10 Amp relay 245 MUG 6, 9-14 Amp relay 246 MUG 10, 13-21 Amp relay 247 MUG 10, 20-32 Amp relay 248 MUG 10, 28-42 Amp relay 249 MUG 15, 11-18 Amp relay 250 MUG 15, 13-22 Amp relay 251 MUG 20, 9-14 Amp relay 252 MUG 20H, 20-32 Amp relay 253 MUG 20H, 28-42 Amp relay 254 MUG 30, 20-33 Amp relay 255 MUG 30, 30-50 Amp relay 256 MUG 40, 30-50 Amp relay 257 MUG 40, 36-60 Amp relay 258 MUG 50,36-50 Amp relay 259 MUG 50, 45-75 Amp relay 260 MUG 75, 45-75 Amp relay 261 MUG 75, 66-110 Amp relay 262 MCCBProviding and fitting of 3-pole 415V MCCB with thermal magnetic release having 36kA breaking capacity (Ics= 100% Icu) (Make: L&T d-sine or equivalent) having max. of thermal release range as under: 263 upto and including 100A (Ics= 50% Icu) 264 125A 265 160A 266 200A 267 250A 268 400A 269 Providing and fitting of 3-pole 415V MCCB with thermal magnetic release having 50kA breaking capacity Ics = 100% Icu (Make: L&T d-sine or equivalent) Having max. of thermal release range as under: 270 125A 271 160A 272 200A 273 250A 274 400A 275 630A 276 Providing of set of spreader terminals for above 3-pole MCCBs 277 100A 278 125A 279 250A 280 400A 281 630A 282 Providing and fitting of 4-pole 415V MCCB with thermal magnetic release having 50kA breaking capacity Ics = 100% Icu (Make: L&T d-sine or similar) Having max. of thermal release range as under: 283 125A 284 160A 285 200A 286 250A 287 400A 288 630A 289 SPARES FOR ACB (L&T C-POWER)Providing and fitting of pole assembly for draw out type ACB (L&T C-power) 290 upto 1250A 291 2000A 292 Providing and fitting of Arc Chute (440V) for ACB (L&T C-power) 293 upto 1250A 294 1600 - 2000A 295 Providing and fitting of Jaw contact for ACB (L&T C-power) 296 630-1000A 297 1250A 298 1600A/ 2000A 299 Providing and fitting of Fixed arcing contact for ACB (L&T C-power) 300 800- 1600A 301 2000A 302 Providing and fitting of Moving arcing contact for ACB (L&T C-power) 303 800- 2000A 304 Providing and fitting of Shunt release for ACB (L&T C-power) 305 Providing and fitting of Under Voltage Release for ACB (L&T C-power) 306 Providing and fitting of Moving arcing contact for ACB (L&T C-power) 307 Providing and fitting of Terminal Adaptor for Draw out L&T C-POWER ACB of ratings as under: 308 upto 800 - 1250A 309 1600 - 2000A 310 Providing and fitting of thermal-Magnetic Release (type DN1) for L&T C-power ACB 311 Providing and fitting of CT for DN1 type L&T C-power ACB 312 800/ 1000A 313 1250/ 1600A 314 2000A 315 Providing and fitting of main spring for 3-pole ACB (L&T C-power) 316 800- 1600A 317 2000A 318 Providing of racking handle for draw-out type ACBs (L&T C-power) rating upto 2000A 319 Providing and replacement of spring charging motor (AC/ DC) 320 Providing and replacement of motor limit switch 321 INSTRUMENTATION AND PANEL ACCESSORIESProviding and fitting of 96x96 flush mounting 3-phase LED ammeter/ voltmeter of Class 1 accuracy (Make: L&T/ Schneider/ Rishabh/ AE) 322 Providing and fitting of flush type analog moving iron AC meter as under:(Make: Rishabh/ AE/ C&S/ BCH) 323 48x48mm 500V voltmeter 324 96x96mm 500V voltmeter 325 144x144mm 500V voltmeter 326 96x96mm ammeter (5A CT operated) 327 Providing and fitting of flush type frequency meter with range 45-55Hz:(Make: Rishabh/ AE/ L&T/ Schneider/ BCH) 328 Providing and fitting of 10A line current ammeter selector switch with OFF (Make: L&T/Rishabh/ AE/ Teknic) 329 Providing and fitting of 10A voltmeter selector switch with OFF(Make: L&T/ Rishabh/ AE/ Teknic) 330 Providing and fitting of tape insulated ring type metering current transformers (AE/ Rishabh/ Crompton/ Kilburn) as under: 331 100/5A or 150/5A - Class 1 - Burden 5VA 332 200/5A - Class 1 - Burden 10VA 333 400/5A - Class 1 - Burden 15VA 334 600/5A - Class 1 - Burden 15VA 335 800/5A - Class 1 - Burden 15VA 336 1000/5A - Class 1 - Burden 15VA 337 2000/5A - Class 1 - Burden 15VA 338 Extra for 1A secondary upto 600/1A over corresponding rate 339 Providing and fitting of analog VAC hour meter(Make: L&T or equivalent make) 340 DIN mounting type 341 Flush mounting type 342 Providing and fitting of flush or projecting head push button with contact block (L&T/ Teknic/ ABB/ BCH/ Schneider or any other reputed make) 343 Providing and fitting of LED phase indicator with surge protection (L&T/ Teknic/ ABB/ BCH/ Schneider or any other reputed make) 344 Providing and fitting 3 Phase, 3/4 Wire adjustable Under & Over Voltage monitoring relay (Minilec VCT D2 or equivalent) 345 Providing, fitting and setting of 415V auto reset single phase preventor (L&T/ Minilec/ BCH or equivalent make) 346 50V or less unbalance & 1 C/ODIN mounted 347 50V or less unbalance & 1 C/OPanel wall mounted 348 70V or less unbalance & 2 C/ODIN mounted 349 Providing and fitting of 32A DP switch (Anchor/ SSK or any other reputed make) 350 Providing of HRC fuses (2A - 32A) ratings 351 Providing and fitting of Fuse holders for fuses upto 32A rating 352 Providing and fixing uPVC panel trunking with cover 353 15x15mm 354 25x25mm 355 TERMINALS/LUGSProviding and crimping of various aluminium tube lugs (Dowells/ Action/ or any other reputed make) with tapping, insulation as under: 356 16 sq. mm 357 25 sq. mm 358 35 sq. mm 359 50 sq. mm 360 70 sq. mm 361 95 sq. mm 362 120 sq. mm 363 150 sq. mm 364 185 sq. mm 365 225 sq. mm 366 240 sq. mm 367 300 sq. mm 368 Providing and crimping of various copper tube lugs (Dowells/ Action/ or any other reputed make) with tapping, insulation as under: 369 16 sq. mm 370 25 sq. mm 371 35 sq. mm 372 50 sq. mm 373 70 sq. mm 374 95 sq. mm 375 120 sq. mm 376 150 sq. mm 377 185 sq. mm 378 225 sq. mm 379 240 sq. mm 380 300 sq. mm 381 CABLESProviding and fitting of PVC insulated 1100V flat 3-core industrial copper cable for submersible pump motors (Preferred makes: Finolex/ L&T/ Havells/ KEI/ Polycab) 382 1.5 sqmm 383 2.5 sqmm 384 4.0 sqmm 385 6.0 sqmm 386 10.0 sqmm 387 16.0 sqmm 388 25.0 sqmm 389 35.0 sqmm 390 Providing and fitting of XLPE insulated, 1100V single core armoured industrial copper cable as under (Preferred make: Finolex/ Gloster/ Havells/ KEI/ Polycab) 391 16.0 sqmm 392 25 sqmm 393 35 sqmm 394 50 sqmm 395 70 sqmm 396 95 sqmm 397 120 sqmm 398 150 sqmm 399 185 sqmm 400 240 sqmm 401 300 sqmm 402 400 sqmm 403 Providing and fitting of XLPE insulated, 1100V single core industrial armoured aluminium cable as under (Preferred make: Finolex/ Gloster/ Havells/ KEI/ Polycab) 404 16 sqmm 405 25 sqmm 406 35 sqmm 407 50 sqmm 408 70 sqmm 409 95 sqmm 410 120 sqmm 411 150 sqmm 412 185 sqmm 413 240 sqmm 414 300 sqmm 415 Providing and fitting of XLPE insulated, 1100V 3.5-core industrial armoured aluminium cable as per IS 7098 (Preferred make: Finolex/ Gloster/ Havells/ KEI/ Polycab) 416 25 sqmm 417 35 sqmm 418 50 sqmm 419 70 sqmm 420 95 sqmm 421 120 sqmm 422 150 sqmm 423 185 sqmm 424 240 sqmm 425 300 sqmm 426 WIRINGProviding and fitting of PVC insulated 1100V flexible copper cable (FRLS) for electrical installations as under (Preferred makes: Finolex/ Anchor/ L&T/ Havells/ KEI/ Polycab) 427 1.0 sqmm 428 1.5 sqmm 429 2.5 sqmm 430 4.0 sqmm 431 6.0 sqmm 432 10.0 sqmm 433 16.0 sqmm 434 2x1.5 sqmm 435 2x2.5 sqmm 436 2x6 sqmm (Aluminium unarmoured) 437 CONDUITS 438 Providing and fixing 25mm PVC round conduit (medium) with allied PVC fittings 439 Providing and fixing uPVC trunking 25x16mm with allied fittings 440 Providing and fixing Polypropylene Corrugated flexible conduit 441 25mm 442 32mm 443 Providing and fitting perforated MS cable trays including horizontal and vertical bends, reducers, tees, cross members and other accessories as required and duly suspended from the ceiling with MS suspenders or fixing on cantilever supports and including painting etc as required. 444 100 x 50 x 1.6mm 445 150 x 50 x 1.6mm 446 ELECTRICAL FITINGSProviding and fitting of various electrical fittings as under(Preferred makes: Anchor/ SSK/ Havells) 447 Switch-6A-SP-1way, 240V, 50 Hz, AC. 448 Switch-6A-SP-2way, 240V, 50 Hz, AC. 449 Cord Switches:- Providing and fitting of cord switch-6A-SP-1way, 240V, 50 Hz, AC/ hanging bell push. 450 Bell push 240V, 50 Hz, AC. 451 6A Socket:- Providing and fitting of6A-2/3 pin-universal socket, 240V, 50 Hz, AC. 452 Neon indicator 453 Mini telephone jack 454 Fan regulator (Mini) with rotary step 455 Fan regulator (Deluxe) with rotary step 456 Shuttered-3 pin socket and switch (box/ recessed) - 20A-SP-1 way, 230V 50 HZ, AC. 457 Plug Top 15/16A 3 Pin (ISI Marked) 458 32A TP switch 415V with neon 459 32A DP switch 240V with neon 460 Surface mounting box for switches as follows: 461 1 Gang box 462 2 Gang box 463 3 Gang box 464 4 Gang box 465 5 Gang box 466 6 Gang box 467 7 Gang box 468 4 Gang box (double domestic) 469 Providing, Fixing, Testing of 6A ceiling rose 470 Providing and installation of Pendant/ angle/ batten holders 6A 240V 471 Providing and installation of SPN sheet steel enclosed Distribution boxes - Single door (Make: L&T/ Legrand/ Hager/ Havells/ Benlo) 472 4 way 473 8 way 474 12 way 475 16 way 476 Providing and installation of ‘B’ Series MCB 240V, 50Hz, 10kA Suitable for lighting and other domestic loads (Preferred Make: L&T/ Legrand/ Hager/ Havells/ Schneider) 477 6-32A SP 478 40A SP 479 6-32A DP 480 40A DP 481 100A 4P isolator 482 Providing and installation of Change over switches of metal enclosure 240v 50Hz (Preferred make: Anchor/ SSK/ Havells/ L&T) 483 2-pole 16A 415V 484 2-pole 32A 415V 485 4-pole 32A 415V 486 4-pole 63A 415V 487 4-pole 100A 415V 488 Providing and installation of Busbar chamber 3-ph 4 bar heavy duty copper strips with rating as under(Preferred make: Havells/ SSK/ L&T) 489 63A 415V 490 100A 415V 491 200A 415V 492 MANPOWER 493 Hiring charges of Electrician (for troubleshooting/ revamping of existing electrical fitting, etc. exclusive of specified works): 494 Hiring charges of Labourer for support of electrician 495 Excavating trenches of required width for pipes, cables, etc in all kinds of soil including excavation for sockets and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m 496 Pipes, cables etc, not exceeding 80 mm dia. 497 Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia 498 Pipes, cables etc. exceeding 300 mm dia but not exceeding 600 mm dia 499 Pipes, cables etc. exceeding 600 mm dia but not exceeding 1200 mm dia 500 Extra for excavating trenches for pipes, cables etc. in all kinds of soil for depth exceeding 1.5 m, but not exceeding 3m. (Rate is over corresponding basic item for depth upto 1.5 metre). 501 Extra for excavating trenches for pipes, cables, etc, in all kinds of soil for depth exceeding 3 m in depth, but not exceeding 4.5 m. (Rate is over corresponding basic item for depth upto 1.5 metre.)
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 6
Jammu And Kashmir View Result →
32.
Drinking Water Supply and Sanitation #10279059 Price Bid
Tender For Rehabilitation Improvement And Basic Facility Of Parbati Dam District Dholpur. - 5.1.2Excavation including loading, unloading, disposal and dressing of excavated earth within initial lead of 50m and lift up to 1.5m including dressing of excavated area and dewatering wherever required complete in all respect Hard / dense soil 2 Dismantling doors, windows and clear story windows (steel or wood) shutters including chowhats, architrave and holdfastsetc. Complete and stacking 50 m lead of area 3 square meter and below 3 Drilling more than 48 mm but upto 76 mm dia, holes in over burden hard soil compacted earth, morrum etc. for consolidation / curtain grouting in stages by percussion drilling including cost of drilling equipment, compressed air, water etc. complete and re-drilling in the hole through set grout if required. From 5 to 10 m depth 4 Providing and fixing welded mesh/expanded metal mesh in frame work, flat iron beading 20x3mm including top cross laps inside and out sides welding, iron bolts, crews, clips etc. complete (excluding frame work) of size.Welded mesh 50 x 50mm x 16 gauge 5 Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from 99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 for lower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5, in existing surface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure A attached with this BSR 6 Providing & Fixing of of Double ball bearing, copper wounded capacitor start single phase metallic blade fresh air fan, in existing opening including cost of hardware , flexible 3 core copper conductor ,making connections, testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . WITH 225 mm sweep 7 SITC of Monoblock motor pump set ISI marked (IS:9079-2002) with TEFC motor, motor should be IE2 class as per IEC 60034-2-1: 2007, IEC 60034-30: 2008, & IS12615:2011. withStainless steel Impellor, Stainless steel shaft, Mechanical seal, Single/Three phase ( 240 - 440 V ) permanent split capacitor type (PSC), fitted with thermal overload protection, Including cost of hardware etc on existing platform complete. Pump shall have following HP Rating, phase, Head, minimum Discharge respectively complete in all respect. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test certificate before execution. All as per pre approved by Engineer in charge. For additional technical parameters of products/work , refer Annexure A attached with this BSR . 0.5 HP, 1-Ø, (3 - 18)Mtr, (100-26) LPM 8 Supply , Installation, Testing and Comissioning of Inverter type Air Cooled Hi Wall split type Air conditioners with latest star rating system as per BEE amended upto date complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU), R-32/R-410 Green Refrigerant, wireless Remote control, suitable for working between 230V +/- 10% with low & high voltage cutoff and 50 hz , single phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 1.5 TR ISEER not less then 3.8 9 Random rubble stone masonry (using R. R. stones where 75 % stones to be not less than 15 cm in size in any direction and weighing not less than 23 kg.) for Superstructureincluding curing all leads of all construction materials including curing etc. complete. in cement sand mortar 1:4 10 Add extra over item No. 18 (b) for compaction in restricted area nearby structure or flanks by hand rammers or by pneumatic tampers. 11 Drilling more than 48 mm but upto 76 mm dia, holes in over burden hard soil compacted earth, morrum etc. for consolidation / curtain grouting in stages by percussion drilling including cost of drilling equipment, compressed air, water etc. complete and re-drilling in the hole through set grout if required. From 10 to 15 m depth 12 Water Bound Macadam (Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with vibratory roller 8-10 tonnes in stages to proper grade and camber, applying and brooming requisite type of screening/ binding Materials to fill up the interstices of coarse aggregate, watering and compacting to the required density.)By Mechanical Means: Grading- I (Using Screening Crushable type such as Moorum or Gravel)Using Screening Crushable type such as Moorum or Gravel 13 11.5.4Drilling more than 48 mm but upto 76 mm dia, holes in over burden hard soil compacted earth, morrum etc. for consolidation / curtain grouting in stages by percussion drilling including cost of drilling equipment, compressed air, water etc. complete and re-drilling in the hole through set grout if required. From 15 to 20 m depth 14 Prime coat (Providing and applying primer coat with bitumen emulsion on prepared surface of granular Base including clearing of road surface and spraying primer at the rate of 0.60kg/sqm using mechanical means 15 Drilling more than 48 mm but upto 76 mm dia, holes in over burden hard soil compacted earth, morrum etc. for consolidation / curtain grouting in stages by percussion drilling including cost of drilling equipment, compressed air, water etc. complete and re-drilling in the hole through set grout if required. From 20 to 25 m depth 16 Tack coat Providing and applying tack coat with bitumen emulsion using emulsion pressure distributor at the rate of 0.20 kg per sqm on the prepared bituminous/granular surface cleaned with mechanical broom 17 Drilling more than 48 mm but upto 76 mm dia, holes in over burden hard soil compacted earth, morrum etc. for consolidation / curtain grouting in stages by percussion drilling including cost of drilling equipment, compressed air, water etc. complete and re-drilling in the hole through set grout if required. Beyond 25 m depth 18 Open - Graded Premix Surfacing (Providing, laying and rolling of open - graded premix surfacing of 20 mm thickness composed of 13.2 mm to 5.6 mm aggregates either using penetration grade bitumen or cut-back or emulsion to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a smooth wheeled roller 8- 10 tonne capacity, finished to required level and grades.)(I)a Case - I: Mechanical method using Penetration grade Bitumen and HMP of appropriate capacity not less than 75 tonnes/hour .Using VG-30 binder 19 Drilling more than 48 mm but upto 76 mm dia, holes in all types of rock or artificial hard material like concrete or masonry for consolidation/ curtain grouting in stages by percussion drilling including cost of drilling equipment, compressed air, water etc. complete and re-drilling in the hole through set grout if required.Up to 5 m. depth 20 Providing and laying premix seal coat using hot mix plant and paver finisher with aggregates of 6.7mm size defined as 100% passing through 11.20mm sieve and retained on 2.36mm sieve with 0.09 cum per 10 Sqm and 4.5%bitumen including preparation and transportation of mix, spreading, laying and rolling etc. complete in all respect including cost of binder.(ii) Bitumen grade VG30 @ 4.50% 21 Drilling more than 48 mm but upto 76 mm dia, holes in all types of rock or artificial hard material like concrete or masonry for consolidation/ curtain grouting in stages by percussion drilling including cost of drilling equipment, compressed air, water etc. complete and re-drilling in the hole through set grout if required.From 5 to 10 m depth 22 dismantling roofs with care including stacking of serviceable material and disposal of unservicable material within 50m lead for lime terrace 23 Supplying and lowering into holes and fixing of casing pipes of suitable diameter to enable drilling of minimum 48 mm dia grout holes. 24 dismantling stone slab roofing over wooden karries or RCC battens ( dismantling karries and battens to be paid for separately) including stacking of servicable material and disposal of unservicable material within 50 m lead 25 11.7Washing and open flushing of drilled holes by alternate jet of air and water under pressure prior to pressure washing and flushing or grout after stage grouting including cost ofequipment, compressed air and etc. complete. 26 Dismanling old plaster or skirting , raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 m lead 27 11.8Normal pressure washing of drilled hole in stages in approved pattern for cleaning of clay, soil and other filler materials from the seams and joints in the foundation rock by establishing connections under pressure with air & water including cost of equipment, accessories compressed air, water, labour, admixtures if any required etc. complete as per specification. 28 Dismantling flooring with care including stacking of servicable material and disposal of unservicable material within 50 m lead for: cement concrete flooring 29 5.16.1Earth work in rough (borrow area) excavation for embankments in hard soil, morrum or highly weathered strata dry or moist, including laying in 20 cm layers (before compaction) and breaking of clods, sorting of grass, pebbles etc. and dressing when compacted by vibro compactor, vibro sheep foot roller, sheep foot roller/pneumatic tyred roller to obtain dry density of at least 98% of Standard Proctor s density with initial lift of 1.5m (Excluding charges for compaction and watering) including loading and un-loading wherever required complete in all respect.With initial lead of 250 m 30 Supply and fixing of steel doors, with frame of hollow metal pressed section 105×60 mm as per I.S.I 1.25mm thick with double sheet shutter 1.00 mm thick M.S. sheet tospot welded and embossed with rib type design on both sides, front side vertical and back side horizontal and spot welded including hold fasts of (15×3mm), M.S. oxidized fittings such as butt hinges sliding door bolts, handles, tower bolts etc. complete in all respect as per drawing and specifications including applying priming coat of approvedsteel primer 31 11.10Conducting water intake test in test holes under pressure for determining permeability before or after grouting including cost of equipment and water etc. complete 32 Earth work in excavation in foundation trenches or drains including dressing of sides & ramming of bottoms , lift up to 1.5 m including taking out the excavated soil & depositing & refilling of jhiri with watering & ramming and disposal of surplus excavated soil as directed within lead of 50 m : all kind of soils 33 11.9Grouting of drilled holes minimum 35 mm dia with or without packers with cement/ clay and or chemicals (in the form of slurry with water) in prescribed ratio till refusal including cost of grouting equipment, compressed air and water etc. complete but excluding cost of cement, clay and chemicals (only dry weight of ingredients excluding chemicals to be considered ) with a working pressure upto 15 kg/Cm2 (Dry cement consumption) 34 Providing and laying in position cement concrete including curing, compaction etc.complete in specified grade excluding the cost of centering and shuttering - all work up to plinth level: M10 grade nominal mix (with graded stone aggregate 20mm nominal size (P.C.C. in foundation) 35 16.33Exploratory vertical drilling of bore holes 150 mm dia through all kind of soils with the adequate / suitable equipments, tools and tackles for depths mesured below existing ground level including mobilization, setting up boring rig, shifting of rig from 1 bore hole to another and demobilization of the same 36 Random Rubble Stone masonry for superstructure above plinth level one storey height above 30 cm thick walls in: cement sand mortar 1:6 37 16.32.3Boring NX dia (54.7 mm dia), hole with diamond coring bits including taking out of core and arranging etc. core in proper order in core boxes including cost of core boxes. as per relevant I.S. code of practice. These rates are including Mobilization & demobilization of Rig. In sand stone and harder variety of lime stone 38 Filling available excavated earth ( excluding rock) in trenches ,plinth side of foundation etc. in layer not exceeding 20 cm. in depth , consolidating each deposited layer by ramming amd watering including lead up to 50 m and with all lift 39 5.1.3Excavation including loading, unloading, disposal and dressing of excavated earth within initial lead of 50m and lift up to 1.5m including dressing of excavated area and dewatering wherever required complete in all respect Hard soil mixed with Kankar / boulders, Morrum 40 Brick masonry in foundation and plinth with bricks of class designation 75 in: cement mortar (1:6) (1 cement : 6 coarse sand) , add extra for superstructure upto third storey 41 10.1.1Side shuttering including propping etc. complete (to achieve finish F 2 for :Block joints of foundation stilling basins buckets, aprons etc. (non -suspended horizontally laid massconcrete) 42 Providing and laying in position specified grade of cement concrete for RCC structural element upto floor three level including curing , compaction, finishing with rendering in cement sand mortar 1:3 (1 cement : 3 coarse sand) and making good the joints excluding the cost of shuttering , centering and reinforcement for: Beams, suspended floors, roofs, girders having slopes up to 15degree, landings, balconies, shelves, chajjas, lintels, bands, plain windows sills, staircase and spiral staircases : M20 grade nominal mix/design mix Desc/Location Nos L B H 43 9.8.3Providing and Laying in position of Cement concrete Nominal mix (1:3:6) including leads of all construction materials, curing, compaction and finishing with rendering in cement sand mortar 1:3 (1 cement : 3 coarse sand) and making good the joints excluding the cost of centering, shuttering and reinforcement. Well graded crusher broken stone aggregate of maximum size upto 40 mm 44 centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways and removal of formwork for foundation in basements rafts, footings, straps beams, bases of column etc up to plinth level 45 9.6.4Providing and Laying in position of Cement concrete Nominal mix (1:1.5:3) including leads of all construction materials, curing, compaction and finishing with rendering in cement sand mortar 1:3 (1 cement : 3 coarse sand) and making good the joints excluding the cost of centering, shuttering and reinforcement. Well graded crusher broken stone aggregate of maximum size upto; 20 mm 46 P/F steel reinforcement for RCC work including cutting bending placing in position and binding complete including cost of binding wire in foundation raft footing step beams base of columns etc. upto floor three level .: Hot rolled deformed bar (IS : 1139) 47 7.1.2Random rubble stone masonry (using R. R. stones where 75 % stones to be not less than 15 cm in size in any direction and weighing not less than 23 kg.) for foundation including curing with all leads of all construction materials including curing etc. complete. In cement sand mortar 1:4 48 PLASTER (Ceiling) 6 mm thick. Cement plaster to ceiling of mix 1:3 (1 cement : 3 fine sand) 49 8.13.2Flush or ruled pointing on stone masonry including racking of joints and curing etc. complete including all leads of all construction materials in mortar ratio. In Cement sandmortar 1:4 50 PLASTER (Internal) Plaster on new surface on wall in cement sand mortar 1:6 including ranking of joints etc. complete fine finished 20 mm thick. 51 5.9.1Extra charges for disposal of excavated/re-handled material in required profile laid in uniform layers and given side slopes well dressed having layer thickness including loading and un-loading wherever required with cost of dewatering wherever required complete in all respectNot exceeding 15cm 52 Painting with enamel paint of approvd brand and manufacture to give an even shade : Two or more coats on new work 53 18.17.2Providing and laying cement concrete coping in (1:2:4) with maximum size of crusher broken aggregate upto 20 mm including shuttering etc. with all leads of material complete in all respect in thickness of: 50 mm 54 Granding for roof water profing treatment with cement motor 1:4 (1 cement : 4 coarse sand) 2 inch thick 55 18.28.1.2Providing, laying and fixing in position RCC spun or hume pipe with collars (ISI 458- 2003) in required size packed in gasket for hume or spun yarn & neatly finished with rich grout of cement mortar 1:3 perfectly air tight including testing of joints. 150mm NP3 56 Polished Blue kota stone flooring Skerting, Laid over 20 mm thick base of cement mortar 1:4 and jointed with Grey cement Slurry to match of the Shade of the Slab including rubbing and polishing complete for area of each slab from 2001 to 5000 sq. cm. 25 mm thick slab 57 11.19Reaming, redrilling and pressure jet flushing of foundation holes of NX size, in the drainage gallery of dam, using diamond drill bit of suitable size, diamond reamer shell with using hydraulically operated rotary core drilling equipments, rods of suitable length to specified depth, fixing PVC pipes with caps, including cost of materials, hire charges of equipments, fuel, labour with all leads and lift etc. complete as directed by Engineer in Charge 58 Providing brick kharanja in cement sand mortar 1:4 in square pattren over roof of ground floor (75 mm to 100 mm thick avarage) Add for if cement mortar 1 : 4 is used instead of lime sand mortar 1 : 2. 59 18.50Cleaning drainage gallery, adits, instrumentation galleries etc. by scrubbing/ brushing including chiseling and removing leached lime deposit and disposing off all the waste materialoutside adits in specified location as directed etc., complete with all leads and lifts. 60 Plaster on new surface on walls in cement sand mortar 1:4 including raking of joints etc. complete fine finish 20 mm thick Add extra over item No. 12.7 to 12.10 for water proofing compound if used @ 2% of the cement by weight. 61 9.8.4Providing and Laying in position of Cement concrete Nominal mix (1:3:6) including leads of all construction materials, curing, compaction and finishing with rendering in cement sandmortar 1:3 (1 cement : 3 coarse sand) and making good the joints excluding the cost of centering, shuttering and reinforcement. Well graded crusher broken stone aggregate of maximum size upto 20 mm 62 Stone slab roofing on ground floor with fine grained stone slab from approved quarry including filling of joints of parapet and slab on both sides in cement sand mortar 1:4 ralthal, stone kharanja, lime terracing 90 mm avarage thickness [as per JAIPUR PRACTICE] with ceiling pointing in cement sand mortar 1:3 per specification for span:above 3.00 metre and upto 3.30 metre. 63 10.1.3Side shuttering including propping etc. complete (to achieve finish F 2 for :Retaining wall, counterfort, abutment, wing walls up stream or down- stream slope facings of dams and open faces of construction joints etc. 64 Providing and fixing T-iron frame for doors windwos and ventilators of mild steel tee-setions, joints mitred and welded with 15x3 mm lugs embedded in cement concrete blocks 15x10x10 cm of 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 200 mm nominal size) or with wooden plugs and screws or rawl plugs and screws or with fixing clips or with bolts and nuts as required including fixing of necessary butts hinges and screws and applying a priming coat of approved quality 65 10.9.2.2Supplying of M.S. reionforcement including labour charges for bending binding and placing in position all reinforcement as per drawing including cost of binding wire and all leadsand lifts using. Tor or ribbed bars (IS :1786-1985) 66 window:Providing and fixing Ms sheet double leaf doors shutter in angle iron frame 35x35x5 mm suitabilly digonally braced with 25x3 mm flat iron above and below lock rail of size 50x5 mm beading extra including all fittings, as per direction of engineer incharge. M.S. Sheet 20 SWG 67 10.9.1Labour charges for steel reinforcement including bending, binding, and placing in position all reinforcement as per drawing including cost of binding wire and all leads and lifts. 68 Doors:-Providing and fixing M.S. sheet 1 mm thick double leaf door shutter in angle iron frame 35x35x5 mm siutabilly diagonally braced with 25x3 mm flat iron above and below lock rail of size 50x5 mm beading extra including all fittings, as per direction of Engg. incharge but excluding cost of chokhats: including two coats of anit-corrosive red oxide primer paint. M.S. Sheet 22 SWG 69 10.10.2Extra labour charges for RCC due to obstruction in laying and placing the reinforced cement concrete due to reinforcement. Columns, slabs, cantilevers projections staircases, lintels, beams, chajjas, Retaining walls, piers, abutments, galleries, arch covers, bed plates, sluice capstan bases etc. 70 Supplying & fixing fixed wire Gauge of 14 mesh X 24 Gauge to the Metal frame of rolled section by metal beading 20X3 with suitable screw at not exceeding 150 mm distance 71 5.8.1Re-handling of excavated material including loading unloading and dressing within initial lead of 50 m and lift of 1.5m with cost of de-watering wherever required and all applicabletaxes and levies etc. complete in all respect Earth / Soil 72 Providing and fixing square bars or other flat welded to window ventilators etc. 10mm x 10mm 73 5.18.2.2(ii)Compaction of earth or highly weathered strataBy mechanical equipment such as sheep foot roller/ pneumatic tyred roller/vibro compactor / vibro sheep foot compactor required as per site condition to obtain dry density of. at least 98% of Standard Proctor s density 74 Polished blue kota stone flooring skirting laid over 20mm thick base of C.M. 1:4 and jointd with grey cement slurry to match the shade of the slab including rubbing & polishing complete: for area of each slab from 901 to 2000 sqcm (a) 25mm thick slab 75 5.9.2Extra charges for disposal of excavated/re-handled material in required profile laid in uniform layers and given side slopes well dressed having layer thickness including loading and un-loading wherever required with cost of dewatering wherever required complete in all respect Not exceeding 20cm 76 Providing & fixing steel gate grating and grills made of angles, tees, square bars or other flats black pipe with holdfast and fitting complete as per design and drawing including cutting welding and fabrication with priming coat of red oxide. 77 5.10.1Beyond initial lead of 50 m & upto 250 m 78 Finishing wall with water proofing cement paint of approved brand & manufracture and of required shade to give an even shade including all scafolding new work (three or more coats) 79 5.30Supplying and laying sand of grade as per design requirement in required profile including all lead & lifts.This item is to be used only for laying filter / inverted filter 80 White washing with lime to give in even shade including all scaffolding on new work (three or more coats). 81 5.31.2Supplying and laying aggregate in layers and profile as specified including all leads & lifts.This item is to be used only for laying filter / inverted filterBroken ballast 20 to 40 mm size 82 P & F rigid PVC pipe (IS 4985 Mark) Class 2nd / (4 kg / sqcm) approved quality / Make including jointing the pipe with solvant cement rubber ring and lubricant 110 mm dia. 83 11.14Prepration of old masonry surfaces before laying of further masonry or concrete over it by cleaning the surface and mortar joints with brushing and raking finally, washing by compressed air & water under pressure 84 PVC bend 110 mm 85 37 mm thick shotcrete by wet mix process, applied with compressed air gun after chipping of defective concrete / masonry, racking the joints, cleaning of surface thoroughly with wet sand blasting after fixing of 9 gauge good quality rust free welded mesh of size 50 mm x 50 mm in TWO layers with anchors / clamps. After racking the joints clean the surface thoroughy by wet sand blasting, anchor the first layer of welded mesh in position and apply 15 mm cement concrete (1:2:1) by pressure gun and after hardening of first layer, anchor second layer of welded wire mesh, apply 22 mm thick cement concrete complete in all respect. Cement concrete comprising of cement, sand, coarse aggregate, water and quick setting compound in the proportion 1:2:1, sand and coarse aggregate conforming to IS 383 and table no. 1 of IS;9012 respectively. 86 Pointing on stone masonry in lime sand mortar 1:2 (1 lime putty : 2 sand) : Raised and cut pointing 87 11.18Add extra over item No. 16 &17 for each subsequent height 3.00 m or part there-of above initial lift of 5 m from ground level (upward or downward) 88 P & F unplasticized poly choride (UPVC) SWR pipe fitting type B for sciland waste discharge system ( IS : 13592: 1992 marked) of approved quality / make 110mm dia 89 12.30.3Providing Rubber seals as per IS:11855 for Dam sluice, canal, barrage, stop dam etc. gates of required size and type and specifications with testing, including all lead and lifts, packing & forwarding charges for all components etc. complete. Rubber seal musical note type 100mmx44mm x14mm (44mm Bulb) Tefloncladded 90 P&F Indian type white glazed vitreous china Ist quality W.C. orissa pan (IS : 2556 mark) with 100 mm vitreous china P or S trap including cutting and making good the wall and floor : size530x410 mm 91 12.40Labour charges for removal of existing wornout/damaged bottom and side rubber seal of Stop Log Gate of Dam by cutting bolts with gas cutter, providing holes in new rubber sealinsertion of sleevs and fixing over gates with nut blots, washer ect including cost of gas (LPG and Oxygen) cylinder etc complete 92 P & F WVC wash basin (Ist quality, I.S. : 2556 mark) of approved make with C.I. brackets duly painted, 1 No. 15 mm C.P. pillar cock (IS : 8934 mark) & 32 mm C.P. brass waste coupling of approved make. 25 mm G.I. waste pipe complete including cutting & making good the wall : Size 450 mm x 300 mm 93 12.38Labour charges for removal of existing wornout/damaged bottom rubber seal of crest Radial Gates, Vertical Gates and Intake Service Well Gates of Dam by cutting bolts with gas cutter, providing holes in new rubber seal insertion of sleevs and fixing over gates with nut blots, washer ect including cost of gas (LPG and Oxygen) cylinder etc complete. 94 P & F G.I pipes (internal work) with G.I. fittings (IS:1239 mark) & MS clamps including cutting and making good the walls and floors : Exposed on wall A (i) 15 mm dia nominal bore 95 5.28.1Watering of earth including cost of carriage of water when source of water is up to 1 Km 96 Painting with enamel paint of approvd brand and manufacture to give an even shade : One or more coats on old work 97 12.39Labour charges for removal of existing wornout/damaged side rubber seal of crest Radial Gates, Vertical Gates and Intake Service Well Gates of Dam by cutting bolts with gas cutter,providing holes in new rubber seal insertion of sleevs and fixing over gates with nut blots, washer ect including cost of gas (LPG and Oxygen) cylinder etc complete 98 P & F PVC storage tank (IS : 12701 marked indicating the BIS license No), of approved make with cover, 25 mm dia 1M long G.I. over flow pipe & 25 cm. long wash out pipe with plug & socket, including making connection etc., complete of approved design : 300 litre capacity. 99 12.31.2Painting of Spillway gates, sluice gates, canal gates (both vertical or radial),stop log gates, exposed embedded parts and all un machined ferrous surface (hoist cylinders, cylinder heads, hydraulic piping, pipe fittings, bonnet covers), exposed to water as per IS 14177,for which surface preparation by blast cleaning of class B primer coat (one coat) of inorganic zinc silicate (preferably airless spray)or alternatively, two coats of zinc rich rimer(containing not less than 85% zinc on dry film) to give dry film thickness of 70 5 micron and finish coat (two coats) of solvent less coal tar epoxy paint using airless spray to provide dry film thickness of 150 5 micron per coats. Thus, total dry film thickness of all the coats, including primer coating, should not be less than 350 microns, this will be include expenses on mobilisation and demobilisation of equipments. For maintenance painting the surface preparation shall be done by appropriate hand and power tool cleaning, prior to hand power tool cleaning. Any heavy layer of rust should be removed by chipping visible oil, grease, dirt and other foreign material be cleaned using solvents like clean mineral spirits, xylol or white gasoline. After hand and power tool cleaning the surface should be cleaned of loose dust and debris and/or blast cleaned as laid down in para 7.0 of IS code 14177. After the surface preparation the primer and finishing coats shall be carried out as provided above for painting etc. complete.Beyond 1.5m height 100 P & F stop cock (IS : 8931 mark), superior quality & of approved make : brass 400 gm. 15 mm nominal bore 101 12.31.2Painting of Spillway gates, sluice gates, canal gates (both vertical or radial),stop log gates, exposed embedded parts and all un machined ferrous surface (hoist cylinders, cylinder heads, hydraulic piping, pipe fittings, bonnet covers), exposed to water as per IS 14177,for which surface preparation by blast cleaning of class B primer coat (one coat) of inorganic zinc silicate (preferably airless spray)or alternatively, two coats of zinc rich rimer(containing not less than 85% zinc on dry film) to give dry film thickness of 70 5 micron and finish coat (two coats) of solvent less coal tar epoxy paint using airless spray to provide dry film thickness of 150 5 micron per coats. Thus, total dry film thickness of all the coats, including primer coating, should not be less than 350 microns, this will be include expenses on mobilisation and demobilisation of equipments. For maintenance painting the surface preparation shall be done by appropriate hand and power tool cleaning, prior to hand power tool cleaning. Any heavy layer of rust should be removed by chipping visible oil, grease, dirt and other foreign material be cleaned using solvents like clean mineral spirits, xylol or white gasoline. After hand and power tool cleaning the surface should be cleaned of loose dust and debris and/or blast cleaned as laid down in para 7.0 of IS code 14177. After the surface preparation the primer and finishing coats shall be carried out as provided above for painting etc. complete.upto1.5m height 102 P & F looking mirrors with P.V.C. frame of approved (Atul, Modi Guard , Saint Gobin or equivalent) size 500 x 400 mm 103 18.13Painting distance mark stone and lettering with light blue white or yellow un-washable paint including cost of material 104 P & F flush cock/flush valve (IS 9758 mark) for WC of approved quality make : CP brass half-turn exposed 25 mm nominal bore. 105 12.37Oiling and greasing of Crest radial gates,Vertical Gates and Intake Service well Gates of Dam including all charges of man and material complete, which include cleaning of wire rope with petrol / diesel and applying Cardium compound to wire ropes, oiling & greasing etc complete as per direction of Engineer-in-Charge 106 Construction of chamber in all type of soil with 300 mm thick masonry in CM 1:6 m 10 cm thick C.C. 1:5:10 in foundation, 20 mm thick insider plaster in cm 1:6 , finished with floating neat cement, 50 mm thick M-15 grade C.C. flooring, earth work etc. complete as per design including disposal of surplus earth with in a lead of 50 mtr. inside size 300 x 300 mm depth up to 0.5 m cement cover with frame. 107 12.4Design, Drawing, fabrication, supply, erection, testing and commissioning of Vertical lift sliding type gate with frame consisting of skin plate, sealing frame, stiffeners, horizontal and vertical girders, guide, stainless steel flat/Brass flat, rivets,wedges, lifting rods etc., with all accessories as per relevant IS code including frame & gate complete set for Canal Cross, Escape, Head regulator /Tank head regulator includingcost of all materials, machinery, labour, cutting, aligning, welding, finishing, cleaning, seal fixing, tools and tackles etc., applying two coat of zinc rich epoxy primer to give dry film thickness of 70 5 microns and finish coat (two coats) of solvent less coal tarepoxy paint using airless spray to provide dry film thickness of 150 5 microns per coat thus total dry film thickness of all coats, including primer coating, should not be less than 350 microns., complete as per specifications and approved drawings with all lead and lifts, including packing & forwarding, transportation charges for structural steel components and other materials. 108 Construction of soakage well in all types of soil of approved drawing, top 90 cm. Portion in 450 mm thick masonry with cm 1:6, 80 mm thick stone slab covering, jointing of slab in cm 1:3, Ralthal, Kharanja 40 mm thick M-15 grade C.C. flooring, earth work etc. complete including disposal of surplus earth with in a lead of 50 mtr. inner dia 90 cm & 10 to 12 mtr deep 109 11.13Preparation of surface of existing concrete surface/ masonry in lime mortar/ cement mortar including removal of organic deposit by washing with etching compound and use of wet sand blasting and final washing the surface with air and water jet including cost of all material and equipment required for the work complete. 110 Providing and fixing 1st quality MAT finished ceremic tile size 300x300mm comfirming to IS : 13753 colour such as white, grey, ivory, fume red brown, light green, light blue and other lightshades in floors, steps, pillars etc. laid on a bed of neat cement slurry including nicely finished joints using water proof joint filler powder (Untile or Roffe make) and finishing with flushpointing in white cement mixed with pigment to match the shade of tile complete (including the cost of cement mortar bed 1:4) Category-A : Kajaria, Jhonson, Somani make 111 12.52.1.11Providind of Rubber Seals as per IS 11855 for dams, sliuce, canals, barrage ,stop log gates etc of required size and type and specifications with testing , including all lead andlifts, packing and forwording charges for all components etc. complete in all respectRubber Seal Musical Knot, Solid Bulb type of Size 75mm 35mm x 10 mm 112 Add extra over item No 7.6.1 and 7.6.2 for using 400x400mm size MAT finished tiles inplace of 300x300mm size 113 12.52.1.9Providind of Rubber Seals as per IS 11855 for dams, sliuce, canals, barrage ,stop log gates etc of required size and type and specifications with testing , including all lead andlifts, packing and forwording charges for all components etc. complete in all respectRubber Seal Musical Knot, Solid Bulb with brass clading type of Size 100mm 45mm x 15 mm 114 Providing & fixing steel glazed doors, windows and ventilators with shutters of standred rolled steel section joint mitred and welded with steel 13x3mm lugs 10 Cm. long embedded in cement concrete blocks 15x10x10 Cm. of 1:2:4 (1-Cement:2-coarse sand:4-graded stone aggregate 20 mm nominal size) or with wooden plugs and screws or rawl plugs and screws orwith fixing clips or with bolts and nuts as required, including providing and fixing of plain glass panes 4mm thick with copper glazing clips and special metal-sash putty of approved make, or metal beading with screws complete including priming coat of approved steel primer, excluding the cost of metal beading and other fittings except necessary hinges of pivots steel handles and peg stay etc. as required. doors 115 12.49.2Oiling, Greasing work of gate parts like Headstock, Headstock parts, Roller Assembly, Operating Rod, Sealing Frame, Guide Tee with all Labor tools and tackles etc. and Materialfor vertical lift sliding type/ fix wheel gates excluding cardium compund and gear oil For gate size above 1 Sqm to 10 Sqm 116 Providing & fixing steel glazed doors, windows and ventilators with shutters of standred rolled steel section joint mitred and welded with steel 13x3mm lugs 10 Cm. long embedded incement concrete blocks 15x10x10 Cm. of 1:2:4 (1-Cement:2-coarse sand:4-graded stone aggregate 20 mm nominal size) or with wooden plugs and screws or rawl plugs and screws orwith fixing clips or with bolts and nuts as required, including providing and fixing of plain glass panes 4mm thick with copper glazing clips and special metal-sash putty of approved make, ormetal beading with screws complete including priming coat of approved steel primer, excluding the cost of metal beading and other fittings except necessary hinges of pivots steelhandles and peg stay etc. as required.windows sidehung(openable) 117 5.33Supplying and laying quarry spalls properly graded but not more than 10cm in size with spreading in required profile including all leads & lifts 118 Distempering with oil bound washable distemperr of approved brand and manufacture to give an even shade including all scaffolding : old work (one oe more coats) including scrapping surface and necessary repairs (a) colour change 119 12.36Operation of vertical / radial gates, hoist operation, stop log gates, Gantry Crane, mono rail etc. at Dams for all seasons round the clock whenever required, as per direction of Engineer in-Charge, by providing sk illed & semi skilled staff well conversant with the work of operation of gates as well as meet out all types maintenance & repair work of gates whenever required in any emergency during operation of the gates including deployment of Chowkidar at gate section of the Dam 120 Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade including all scaffolding : New work (two or more coats) over and includingscrapping and priming coat with cement primer 121 5.2.2Excavation including loading unloading disposal and dressing of excavated rock within initial lead of 50m and lift upto 1.5m in dry or moist including dressing of excavated area, dewatering wherever required complete in all respect.Hard rock not requiring blasting 122 P & F bib cock (IS : 8931 mark), superior quality of approved make : Brass 400 grm, 15 mm nominal bore 123 18.1.2Cutting & clearance of jungle, bushes, shrubs Ankra/Ipomoea, Juliflora typna etc. on canal and bunds in dry/moist/slushy conditions including disposal as per instructions of the Engineer-in-charge. Cost of wood has been deducted from rates and thus will be property of contractor after cutting. Thick 124 P&F sand cast iron (S.C.I.) Pipe (IS:1729 mark) of approved make in wall in floor with MS holder bat clamps in 10X10X10 cm. M15 grade concrete block joints filled with CM 1:4 with spun yard including cutting holes and making good the wall.150mm dia. 125 17.5.2Demolishing stone rubble masonry including stacking of usable material and disposal of unuseable material within 50 meters lead inclusive of de-watering wherever required.In cement mortar 126 P&F SCI fittings (IS1729mark) in CM 1:4 spun yarn150mm w/o door Bend 127 5.2.3Excavation including loading unloading disposal and dressing of excavated rock within initial lead of 50m and lift upto 1.5m in dry or moist including dressing of excavated area, dewatering wherever required complete in all respect.Phylite & other hard rock requiring nominal blasting 128 spray painting with flat wall paint of approved brand and manufacture to give an even shade : two oe more coats on new work including priming coat of distemper primer of approved brandand manufacture 129 11.2.1Drilling 35 mm.to 48 mm. Dia holes in all types of rock or artificial hard material like concrete or masonary for consolidation/ curtain grouting in stages by percussion drillingincluding cost of drilling equipment, compressed air, water etc. complete & re-drilling in the hole through set grout, if required.Up to 5 m. depth 130 S&F following sizes (dia.) of ISI marked ( IS:9537 P - II ) rigid steel conduit with wall thickness according to IS Specified along with ISI marked (IS:14768 P-II 2003) accessories in recessed using saddles, clamps, fasteners, pvc bushes, check nuts, as required including cutting jhiris in the wall and making good the same as required. For additional technical parameters of product / work refer Annexure A attached with this BSR. dia 50mm 131 11.2.2Drilling 35 mm.to 48 mm. Dia holes in all types of rock or artificial hard material like concrete or masonary for consolidation/ curtain grouting in stages by percussion drilling including cost of drilling equipment, compressed air, water etc. complete & re-drilling in the hole through set grout, if required.From 5 to 10 m depth 132 S&Providing & Fixing of ISO certified company made off load change over switch four pole/two pole, 230/ 415 V ,side handle operated conforming to IS:13947 P-III in sheet steelenclosure complete with connections with lugs, testing etc. as required in the following rating: All as per pre approved by Engineer in charge. For additional technical parameters ofproducts/ work , refer Annexure A attached with this BSR . 32 A, Four poleF following sizes (dia.) of ISI marked ( IS:9537 P - II ) rigid steel conduit with wall thickness according toIS Specified along with ISI marked (IS:14768 P-II 2003) accessories in recessed using saddles, clamps, fasteners, pvc bushes, check nuts, as required including cutting jhiris in the wall and making good the same as required. For additional technical parameters of product / work refer Annexure A attached with this BSR. dia 50mm 133 2.9.2Cement OPC (in bags) 50 Kg in weight. As per IS 1489 and IS 8112 (excluding cost ofempty begs). 134 S&PP & F paper phenolic resin bonded laminates confirming to IS : 2036 - 1995 for boxes/ frames including making holes for switches etc, with brass screws, washers/ zinc plated nutand bolts as required. For additional technical parameters of product / work refer Annexure A attached with this BSRroviding & Fixing of ISO certified company made off load change overswitch four pole/two pole, 230/ 415 V ,side handle operated conforming to IS:13947 P-III in sheet steel enclosure complete with connections with lugs, testing etc. as required in thefollowing rating: All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 32 A, Four poleFfollowing sizes (dia.) of ISI marked ( IS:9537 P - II ) rigid steel conduit with wall thickness according to IS Specified along with ISI marked (IS:14768 P-II 2003) accessories in recessed using saddles, clamps, fasteners, pvc bushes, check nuts, as required including cutting jhiris in the wall and making good the same as required. For additional technical parameters of product / work refer Annexure A attached with this BSR. dia 50mm 6.4 mmthick 135 10.2Centering and shuttering for slabs, beams, lintels Columns, trough with or without caps and base including propping and remove 136 P & F paper phenolic resin bonded laminates confirming to IS : 2036 - 1995 for boxes/frames including making holes for switches etc, with brass screws, washers/ zinc plated nut and bolts as required. For additional technical parameters of product / work refer Annexure Aattached with this BSR 9 mm thick 137 11.1.1.1Drilling holes of 35 mm diameter for anchor rods.Upto 1.50 m. depth 138 Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity(B/ C/D tripping characteristic as per type of load and site requirement) 4 KV impulsewithstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting of class 3 as per IEC, minimumphase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted in existing distribution board/sheets, minimum electrical operation20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above rating including makingconnections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in charge. Foradditional technical parameters of product / work refer Annexure A attached with this BSR (a) 6 Amp to 32 Amp rating 139 5.35.3Supplying stone, spall and laying R. R. stone pitching, hammer dressed with packing ofvoids from small stones including all lead & lifts, in required profile of 23 cm thickness ( 5 % thickness tolerance) 140 Providing corrugated G.I. Sheet roofing fixed with G.I.J. or L hooks bolts and nuts 8mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead and including a coat of approved steel primer and two coat of approved paint on over lapping of sheet complete (upto a pitch of 60o) & excluding the cost of purlins rafters and truses, for class of sheets :1.60mm thick 141 11.1.2Labour charges for Fixing of anchor bars in neat cement grout including cost of cement and curing etc. complete 142 Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load and site requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contactprotection and fitted in existing distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above rating including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDAaccrediated lab type test reports & All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR Triple pole MCB 50/63 A rating 143 11.1.3Supply of Tor steel anchor bars of required diameter, length and shape at site of work complete. 144 Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load and site requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contactprotection and fitted in existing distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above rating including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR (c) Double pole MCBS of 50 AMP to 63 AMP 145 12.7Design, Drawing, fabrication, supply, erection, testing and commissioning of Adequate capacity manually operated rope drum hoist according to relevant IS code, consisting ofhoist platform bridge, rope drums, connecting shaft, gear system unit, pulleys, wire rope, Gate position indicator, manual operation system, etc. complete, with all accessories for operating gates including cost of all materials, machinery, labour, cutting, aligning, anchoring, welding, finishing, cleaning, greasing, oil filling, tools and tackles, applying two coats of zinc chromate red oxide primer and three coats of approved synthetic enamel paint etc., complete as per specifications and approved drawings, including packing & forwarding, transportation charges for all materials. 146 Providing & Fixing of Recessed/surface mounting heavy duty horizontal type Double Door (Metal / Glazed )Distribution board with Metal end box made out from Galvanized steel /CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3, powder painted complete with reversible door (for double door DB only )100 amp. insulated copper bus bar/shorting link , copper neutral link, copper earth link , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, Ferrules, detachable gland plate, including makingconnections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 4 way Metal door (single phase) 147 12.1.1Design, drawing, fabrication, supply, erection, testing and commissioning of Embedded parts consisting of sill beams, vertical tracks, vertical seal tracks, sealing frame, guide tracks/rails, wall plates, seal seats, anchors, anchor girders, yoke girders, tie flats, trunnion supports, rope and pulley supports etc. and any required necessary item, with all accessories as per relevant IS code, for all type radial gates/ Vertical lift fix wheel type sluice and Canal gates/Stop log gates including cost of all materials, machinery, labour, cutting,aligning, anchoring, welding, finishing, cleaning, tools and tackles, applying two coat of zinc rich epoxy primer to give dry film thickness of 70 5 microns and finish coat (two coats) of solvent less coal tar epoxy paint using airless spray to provide dry film thicknessof 150 5 microns per coat thus total dry film thickness of all coats, including primer coating, should not be less than 350 microns., including packing & forwarding, transportation charges complete item, as per specifications and approved drawings 148 Providing & Fixing of Recessed/surface mounting heavy duty horizontal type Double Door (metal / Glazed )Distributio board with Metal end box made out from Galvanized steel /CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3, powder painted complete with reversible door (for double door DB only )100 amp. insulated copper bus bar/shorting link , copper neutral link, copper earth link , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, Ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in charge. Foradditional technical parameters of product / work refer Annexure A attached with this BSR 12 way Metal door (single phase) 149 18.49Under water videography of dam body & its appertunance i.e gates, under sluice, emergency gate grooves clearly showing location defect area or area of interest indicatingcondition from all possible angles and special focus on damaged portions complete in all respects upto the satisfaction of Engineer in charge. The work also includes supply of three sets of video in digital form and a depth wise report prepared in hard copy 150 Providing & fixing in position frame made out of MS angle (riveted or welded) finished with two coat of red oxide and enamel paint of following size as required 38*38*6 mm 151 12.8.1Design, Drawing, fabrication, supply, erection, testing and commissioning of Adequate capacity manually operated screw type hoist according to relevant IS code, consisting of supporting structure, platform bridge etc., operating handle, gate positionindicator, plumber block, couplings with all required accessories for operating Head/cross/escape regulator gate including cost of all materials, machinery, labour, tools and tackeles, cutting, aligning, anchoring, welding, finishing, cleaning, greasing, oiling, applying two coats of zinc chromate red oxide primer and three coats of approved synthetic enamel paint etc., complete as per specifications and approved drawings with all lead and lifts,including packing & forwarding, transportation charges for structural steel components and other materials. 152 Providing & Fixing of energy efficient direct fit (Retrofit) Polycarbonate/ Glass housing SMD Mid Power LED tube rod (with integral driver & alumn. heat sink ), on existing fixture. systemlumen efficacy ≥ 100 lm/Watt output, internal surge protection of 2.5 KV ,THD < 20% ,p.f.≥0. 95,CRI >80 , life time of minimum 35000 Burning Hours with , 70% of intial Lumen maintanedtill life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80)certificate / Report from OEM shall besubmitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR .600mm , Min. Lumens output 1800 lm LED Tube rod with Polycarbonate Housing 153 5.15.1.1Earth work in excavation in foundation, trenches etc. including dressing of sides and ramming of bottoms, including getting out the excavated material, refilling after laying pipe/foundation and disposal of surplus excavated material at a lead upto 50m suitable site as per direction of Engineer for following depths, below natural ground / Road top level. In all typessoils/ saturated soil such as morrum, sand, sandy silt, clay, black cotton soil, kankar, etc. Depth upto 1.5 m 154 Providing & Fixing of 240/415 V factory fitted RCBO with overload, short-circuit and earth leakage protection with ISI marked (IS12640-2)/ conforming to IEC 61009-1, breaking capacity 10 KA, provision for pad lock, min. Electrical operation 10,000 upto 63 A rating ,minimum phase termination capacity of 35sq.mm. , IP 20 contact protection with existing distribution board / sheet including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR Four pole 100/300 mA sensitivity 40 A rating 155 7.1.3Random rubble stone masonry (using R. R. stones where 75 % stones to be not less than 15 cm in size in any direction and weighing not less than 23 kg.) for foundation includingcuring with all leads of all construction materials including curing etc. complete. In cement sand mortar 1:5 156 Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of1.1 kV grade . Wire should be made from 99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 for lower watt loss , oxygen free for less chances of oxidization, insulationPVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5, in existing surface or recessed PVC/ MS conduit/casing capping making connectionswith Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parametersof product / work refer Annexure A attached with this BSR 1 *2.5 sq.mm 157 9.3.1Providing and Laying in position of Cement concrete Design mix M-25 including leads of all construction materials, plasticizers (if required), curing, compaction and finishing withrendering in cement sand mortar 1:3 ( 1 cement : 3 coarse sand) and making good the joints excluding the cost of centering, shuttering and reinforcement. Well graded crusher brokenstone aggregate of maximum size upto;(For mix design Cement content considered 420 kg/ cum of concrete) 150 mm 158 Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from 99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 for lower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5, in existing surface or recessed PVC/ MS conduit/casing capping making connectionswith Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own inhouse NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure A attached with this BSR 1*6.00 sq.mm 159 7.10.2Brick masonry (using well burnt clay bricks of size 230 x 110 x 70 mm, class designation 75 as per specification) up to plinth including all leads of all construction materialsincluding curing etc. complete. In cement sand mortar 1:4 160 Supply and erection of GI stay set confirming to pattern-1 of BS:16/1974 and as per latest Discom Specifications complete with stay rod with anchor plate fitted with cast iron crosshead and steel bow, in cement concrete 1:3:6 including excavation of pit-re-filling etc complete as reqd. All as per pre approved by Engineer in charge.For additional technicalparameters of product / work refer Annexure A attached with this BSR. Stay set of dia 16mm,1.8m long stay rod and anchor plate 300 x 300 x 4.0 mm 161 5.26Threading / turfing of grass on slopes of bunds etc. in rows 15 cm centre to centre in each direction including Ploughing, levelling, breaking of clods, and removal of stones etc. ifrequired including maintenance for 30 days or more till the grass develops fully with all leads and lifts complete 162 Add extra over item No. 10.25 for providing and fixing CGI sheets in curved roofing 163 8.2.1Plaster in cement sand mortar 1:4 including racking of joints, smooth finishing & curing etc. complete including all leads of all construction materials of thickness: 20 mm 164 Supply and fixing of LT porcelain pin insulator as per IS 1445-1997 and as per Discomsstandard specifications,suitable for working voltage 1100 volts including all accessories like MS Forged GI LT Pin confirming to IS:7935/1975 (latest amended) Nut, Bolt etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure A attached with this BSR 100 mm x 70 mm 165 10.1.110.1 Supply, installation, testing and commissioning of MNRE approved Grid tied Solar Panels with inverter, meter, cable etc. suitable for Rooftop installation as well as Utility ScaleSolar Power Projects with 25 years of Linear Generation warranty. Work includes designing of solar panel area and MS frame and foundation on ground/roof of Pump house or CWR,showing arrangement of panel in available space, installation of PV module on MS frame as per approved design and drawings. Mounting structure shall be suitably designed towithstand wind velocity up to 150km/hr.Grid Tie Transformer less inverters, Multiple independent MPPTs, Peak efficiency of more than 98%. Connect up to multiple strings PV arrays, Easy & fast connection, Built-in stringlevelmonitoring, IP65 protection level, Wi-Fi / internet based remote monitoring with 5 years warranty. All cabling up to panel and metre, earthing etc. required accessories and taxes are inclusive.The work shall be executed as per detailed technical specifications, approved drawing and direction of Engineer in Charge Note: There shall be 5 year service warranty for panel, inverter, meter, cable etc. andsuitable provision shall be included in tender document.10.1.1 Solar panels up to 10 KW at a single location. 166 Supplying and drawing overhead steel core Aluminium conductor (ACSR) ISI marked(IS 398 part II-1996) on existing cross arms through insulator with all necessary T&P required including binding and twisting etc. complete in all respect as required. All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure Attached with this BSR 30 Sqmm of (6+1) 2.59mm (Weasel) 167 16.12Hire charges of DGPS instrument with operator and staff for bench mark shifting, topography survey, command area survey, canal survey, dam survey etc. and collection ofdata, plotting the details and preparing digital map of area in layers, and developing contours where ever required as directed by engineer in charge; including supply of detailed drawingsin appropriate scale in soft copy & three sets of Hard copy complete in all respect. These rates are including all types of taxes applicable 168 Providing & Fixing of 6 amp. Combined flush type non modular socket and switch set as per PWD specification for electrical Works,made out from industrial grade Polycarbonate or fireresistant ABS material including cutting hole in tile and making connection testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parametersof products/ work , refer Annexure A attached with this BSR 169 16.14.1.3Transfer of Dam / Canal alignment from sajra map to the ground and taking Levels by Auto level or DGPS, develo ping L-section and X-section and submitting in hard copy threesets and soft copy in Auto Cad format, using layer system, showing all features. (Total length of L-section and X-section to be measured for payment) L-section of Dam/ Canal (ii) InPlain area - Levels for L-section to be taken at interval 30 meter. 170 Providing & Fixing of IP 20 box made out from 1.2mm thick CRCA sheet steel with depth of minimun 30 mm and finished with powder coating and suitable for mounting LED tubeincluding side covers, holders , internal wiring to illuminate the single sided connection LED tube. ( Without tube). All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . Suitable for 2 LED Tube shape fixture for single rod 171 16.14.2.3Transfer of Dam / Canal alignment from sajra map to the ground and taking Levels by Auto level or DGPS, developing L-section and X-section and submitting in hard copy threesets and soft copy in Auto Cad format, using layer system, showing all features. (Total length of L-section and X-section to be measured for payment) X-section of Dam/ Canal(Total length of X-section shall be measured) (ii) In Plain area - Levels for X-section be taken at interval 5meter 172 Plate Earthing as per IS:3043 with copper Earth plate of purity >95% of size 600mm x 600mm x 3.0mm by embodying 3 mtr. below the ground level with 20 mm dia. G.I. B classwatering Pipe ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lidsuitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height 250 to 300 mm. and embodying the pipe complete with alternatelayers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or less as required & must record by engineer in charge during site visit and ensure to enter inmeasurment book. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 173 16.10Grid survey at interval of 30 x 30 meter to conduct submergence survey with TS / DGPSinstrument and prepare 0.50 m interval contour plan and superimposing over khasra map including all ancillary works as described in specifications and conditions of contract. Note: Khasra map will be provided by Department Marking of existing FRL, MWL, MDDL contours and dam alignment. Prepare area-elevation and storage -elevation curves andtables. 174 Providing & Fixing of energy efficient direct fit (Retrofit) Polycarbonate/ Glass housing SMD Mid Power LED tube rod (with integral driver & alumn. heat sink ), on existing fixture. system lumen efficacy ≥ 100 lm/Watt output, internal surge protection of 2.5 KV ,THD < 20% ,p.f.≥0. 95,CRI >80 , life time of minimum 35000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80)certificate / Report from OEM shall besubmitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR .1200mm , Min. Lumens output 2000 lm LED Tube rod with Polycarbonate Housing 175 16.6.1Digitization of Jamabandi and providing excel sheet to the department Note: Jamabandi Register will be provided by Department 176 SITC of Radiator Cooled and Turbo charged Silent DG Set (As per latest CPCB emission norms) having specifications as per A, B, C, D, E, F,G,H & I 62.5 KVA at 0.8 pf 415V 50Hz 3-ǿ 177 16.6.2Digitization of Khasra map with details in layers and providing soft copy (acad file) Note: Khasra map will be provided by Department 178 SITC of PLC Based Auto main failure (AMF) Panel fabricated from CRCA sheet steel 2 mmThick , Powder coated finish , Engine Start & Stop commands, control Relays , Ammeter& Voltmeter with selector switches, Control & 2 nos 4 pole Power Contactors with 2 no. of required size 4 pole MCCB, Timers, Electronic Hooter ,Visual & Alarm indication for faults,UPS, operator interface panel complete in all respect suitable for following capacity DG sets: Appropriate Test Certificate/ report of product/accessories from OEM/Panel Manufecturershall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ wo rk , refer Annexure A attached with this BSR . 50 to 82.5 kva 179 5.10.4Add extra for each subsequent lead of 1 km or part there of beyond 5 Km 180 Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq. mmnominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS: 694) in recessed ISI marked ( IS:9537 P - II ) rigid steel conduit & its ISI marked (IS:14768P-II 2003) accessories, round tiles,Hot Dipped Galvanized Modular Box of 1.2 mm thick with earth terminal, 10A Modular switch,3 pin ceiling rose / holder / 3 way connector ,Modular faceplate with grid plate, pvc bushes, check nuts, screws, making connections, testing etc. as required. For specification of copper Conductor, Phenolic Laminated sheets & Electrical/Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR i- shortpoint (upto 3 Mtr) 181 Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq. mmnominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS: 694) in recessed ISI marked ( IS:9537 P - II ) rigid steel conduit & its ISI marked (IS:14768P-II 2003) accessories, round tiles,Hot Dipped Galvanized Modular Box of 1.2 mm thick with earth terminal, 10A Modular switch,3 pin ceiling rose / holder / 3 way connector ,Modular faceplate with grid plate, pvc bushes, check nuts, screws, making connections, testing etc. as required. For specification of copper Conductor, Phenolic Laminated sheets & Electrical/Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR ii - Medium point (upto 6 Mtr) 182 11.5.1Drilling more than 48 mm but upto 76 mm dia, holes in over burden hard soil compacted earth, morrum etc. for consolidation / curtain grouting in stages by percussion drilling including cost of drilling equipment, compressed air, water etc. complete and re-drilling in the hole through set grout if required.Up to 5 m. depth 183 Structural steel work riveted or bolted in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete above plinth level upto 4.5 mtr height.In flats, tees, angles and channels. 184 Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq. mmnominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS: 694) in recessed ISI marked ( IS:9537 P - II ) rigid steel conduit & its ISI marked (IS:14768P-II 2003) accessories, round tiles,Hot Dipped Galvanized Modular Box of 1.2 mm thick with earth terminal, 10A Modular switch,3 pin ceiling rose / holder / 3 way connector ,Modular faceplate with grid plate, pvc bushes, check nuts, screws, making connections, testing etc. as required. For specification of copper Conductor, Phenolic Laminated sheets & Electrical/Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR iii - Long point (upto 10 Mtr) 185 Rewiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVCinsulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit & its ISI marked (IS:3419-1988)accessories, 1.2 mm thick MS box with earth terminal of required size, 6 A switch, 3/5 pin 6 A socket, 3.0 mm thick ISI marked (IS:2036-1995) phenolic laminated sheet, Al.alloy /Cadmium plated iron/ brass screws, cup washers, making connections, testing etc. as required. For specification of copper Conductor, Phenolic Laminated sheets & Electrical/Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR :on board 186 Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity(B/ C/D tripping characteristic as per type of load and site requirement) 4 KV impulsewithstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2,low watt losses, trip free mechanisum , energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted in existing distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above rating including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 40A rating 187 P & F 1.2mm thick M.S. Recessed fan box, hexagonal/ round of size 130 mm dia, depth 75mm, 12 mm dia rod fanhook with 100 mm length extended on each side . All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 188 Providing & Fixing of BEE Star rated copper wounded double ball bearing capacitor start, aluminium body & Metallic blade ceiling fan Conforming to all the performance requirementslaid down in IS 374:2019 including all amendments, as applicable ; & Carry BIS licensing (i.e. ISI marking) with down rod up to 80 cm with secondary support safety cable ( steel rope) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. All as per pre approved by Engineer in charge. For additionaltechnical parameters of products/ work , refer Annexure A attached with this BSR . 1200 mm Sweep BEE 1 Star rated (service value >=4.0 to < 4.5 ) 189 Providing & Fixing of IS 11037:1984 marked non modular socket size flush type 180 watt rotary minimum 5 step fan regulator with CM/L no. printed and made out from industrial gradePolycarbonate or fire resistant ABS material including making connection testing etc. as required.All as per pre approved by Engineer in charge. For additional technical parametersof products/ work , refer Annexure A attached with this BSR . 190 Providing & Fixing of IP 20 box made out from 1.2mm thick CRCA sheet steel with depth of minimun 30 mm and finished with powder coating and suitable for mounting LED tubeincluding side covers, holders , internal wiring to illuminate the single sided connection LED tube. ( Without tube). All as per pre approved by Engineer in charge. For additional technicalparameters of products/ work , refer Annexure A attached with this BSR 191 Providing & Fixing of energy efficient /energy saving IP 20 LED direct retrofit Bulb in existing holder or fixture as required with system lumen efficacy ≥100 lm/Watt output ,pf 0.95 , CRI>70, minimum life time of minimum 25000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) certificate / Report from OEM shall be submitted. All as per pre approved by engineer in charge . for additional technical parameters of product/ work, refer Annexure A attacheded with this BSR. 9 watt 192 P & F paper phenolic resin bonded laminates confirming to IS : 2036 - 1995 for boxes/ frames including making holes for switches etc, with brass screws, washers/ zinc plated nutand bolts as required. For additional technical parameters of product / work refer Annexure A attached with this BSR : 4.8 mm thick 193 Providing & Fixing of ISI marked (IS:1258) batten/angle lamp holder with CM/L no. printed and made out from industrial grade Polycarbonate or fire resistant ABS material, brassterminal & captive screwsincluding making connection testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work ,refer Annexure A attached with this BSR 194 providing of 18mm wire rope galvanised 6x36 construction IWRC (steel core) RHOL (right hand ordinary lay) & tensile strength of 1960 N/mm confirming to IS :2266/89 195 Chair type 7 {Revolving chair medium back, support backrest symmetrical lumber support, back cover mesh fabric) (inclusive all taxes) 196 Dressing of earth work in surface excavation including cutting and filling upto 30cm depth including disposal of excavated earth upto 50m and lift upto 1.5 m. 197 Providing laying, spreading and compacting stone aggregates of specific sizes as per Table 400-7 to Water Bound Macadam specification including spreading in uniform thickness; handpacking, rolling with power roller 8-10 tonnes, in stages to proper grade and camber, applying and brooming requisite type of screening (Table 400-8) binding materials to fill up theinterstices of coarse aggregates, watering (with water browser) and compacting to required density, making necessary earthen bund to protect edges as per clause 404 of MoRT&Hspecification including all material, labour, machinery, lighting, guarding and maintenance of diversion complete : Crusher broken Grade II (63-45 mm) 198 Providing and laying lean cement concrete 1:4:8 in Sub- base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 150 kg/ cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in concrete mixer, laid manualy, compacted with surface vibrator, finishing and curing complete as per clause 601, 112 of MoRT&H specificationincluding all material, labour, machinery, lighting, guarding and maintenance of diversion 199 Chair type 4 {chair type with arms,frame type 4 legs,castors without (inclusive of all taxes)} 200 Providing and laying un-reinforced, dowel jointed, plain cement concrete mix With Concrete Mixer & vibrator pavement over a prepared sub base with 43 grade cement , coarse and fineaggregate conforming to IS: 383, maximum size of coarse aggregate not exceeding 25 mm, mixed as per approved mix design, laid, spread, compacted and finished in a continuousoperation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separation membrane, sealant primer, joint sealant, debonding strip, admixtures (if required) as approved, curing compound, finishing to lines and grades complete as per drawing and as per clause 602, 112 of MoRT&H specification including all material, labour,machinery, lighting, guarding and maintenance of diversion. PCC M-25 201 Providing & Fixing of IK07 IP-66 protected high power LED flood light system with Pressure diecast aluminium housing LM6/ ADC12 material , toughened glass diffuser with suitable lenses on LED to achieve various beam angles, 240 volt, 50Hz, of high power LED lamps . Integrated driver must be potted & has a unique BIS R number shall be high efficiency having efficiency more than 85 % and in compliance to BIS certified and T.C. certificate. The System level Luminaire efficacy >=120 lm/ wt with High Power LEDs is to be used . LED driver Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety . Input Frequency 50Hz±3%, Power Factor >0.95 ,driver Efficiency >85% , THD(I) <10% , driver current <1000mA shown in LM79 report. driver should be Phase to phase protection of 440 V for 4 Hrs. Electrical Connector Must be rovided, Surge Protection Min >=4KV internal and 10KV external, System life of 30000 Burning hours with 70% of Initial Lumens maintained, color Rendering Index >70 and CCT 5700K ±355K. Driver current <1000mA shown in LM79 report. Manufactures Word Mark/Name Engraved/Embossing/Screen printing on die cast housing to allow raceability/authenticity. Fixture shall be IS 10322 Complianced. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures . (LM79/LM80) certificate/report with liable warranty of product/accessories from OEM shall be submitted . All as per approved by Engineer In charge . for additional technical parameters of products/works . High Power LED Flood 202 Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing and staircase railing including applying a priming coat of approved steel primer. M.S tube 203 Octagonal MS Poles made of S-355JO grade steel sheet , folded lengthwise to obtained Octagonal shape, having single longitudinal seam weld and hot dipped galvanised internally & externally in accordance with IS 2629. 4 meter 204 Supply, Erection and Fixing of hot dipped galvanised M.S. Overhang (48.3 X 3.25 mm) with cap (400 x 88.9 / 114.3 x 3.25 mm) over the existing poles. All as per pre approved byEngineer in charge. For additional technical parameters of products/ work . Double arm overhang 205 providing of 24 mm wire rope galvanised 6x36 construction IWRC (steel core) RHOL (right hand ordinary lay) & tensile strength of 1960 N/mm confirming to IS :2266/89 206 Supply installation testing & Commissioning of ISO certified company made high mast lighting system (as per PLG 07 of ILP UK techinical report no 7 of ILE UK /IS:875 Part-1 –2015//BSEN10025/and IS:2062 )consisting of totally hot dip galvanised by single dipped method high mast, lantern carriage suitable for up to 12 nos luminaries with welded arm (excluding luminares), mast head frame assembly with full cover, including 1 No. LED 15 Watts aviation obstruction lights, double drum type self sustaining winch, inte gral power tool accesible from door with padlocking arrangement ( winch motor with control circuit) hot dipped galvanised heavy duty pipe lightening finial, S.S. ropes (AISI 316, 7 / 19 costruction ), EPR insulated PCP sheathed trailing cable, including outdoor type control panel for auto on / off, reverse / forward motor operation and CC foundation of M - 25 grade complete as required as per IS 456/IS 2911. The mast is constructed from mild steel plates (as per IS 5986 Gr. 510 ) cut and folded to form a polygonal section, telescopic jointed and welding as per BS 5135. ( See table P - 03 for specs.) OEM must have type test certificate for wind tunnel test for high mast fixtures , complete in all respect .All asper pre approved by Engineer in charge ,for additional technical parameters of products/work. 16.0 Mtr HM(in 2section) 207 Labour charge for removing old wire ropes and fixing of new wire ropes with all accessories and T&P etc complete 208 oiling & greasing of gantry crane on Parbati Dam Which includes complete Removal of all old worn out & broken down parts, cables, connections etc complete checking of all copper wiring, all wiring & connections control panel , all switches etc complete with all material , labout, T&P and lead and lift complete in all respect 209 Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/ 10 sqm of approvedbrand or manufacture 210 Providing and fixing of precast concrete interlocking tiles of desired shape of M 30 grade manufactured from fully computerized automatic stationery hydraulic vibrio pressed machine and fully computerized automatic batching plant of class A1/A2 as per BS 6717:2001. The CC interlocking paving blocks be laid on average 50mm. thick bed of coarse sand and the joint is to be filled with fine sand. Laying procedure on compacted sub-base as defined. Complete job is to be executed as per the instruction of Engineer in charge. The rates to be inclusive of all lead & Lifts etc. complete as per specifications. Tensile splitting strength, abrasion and braking load etc. as per BS 6717:2001, Grey cement. : 80mm thick 211 Table type 3 (storage provided one side,length of table top-1200 mm, depth of table top-600 mm) 212 Providing sofa set(Frame covering fully upholstered, Total No of seats in sofa set -4, covering material for seat and back rest-leatherite) 213 Table type 5 (seating capacity - 8 seater, width in mm -1200, Length in mm - 2400mm, shape of table top Rectangular , height in mm - 750 mm ) (inclusive all taxes)
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
33.
Health and Family Welfare #10276803 Price Bid
Tender For Electrification Work At Construction Of Chc Building At Jhinjhiyali District Jaisalmer - Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)inrecessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit & itsISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thickHot Dipped Galvanized Modular Box with earth terminal, 10A Modular switch,Modular face plate with grid plate, 3 pin ceiling rose / Holder /3 way connector, screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR 2 Short point (up to 3 mtr.) 3 Medium point (up to 6 mtr.) 4 Long point(up to 10 mtr.) 5 Wiring of twin control light point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)in recessed ISI markedMMS ( IS:9537 P - III ) PVC conduit & its ISI marked (IS:3419-1988) accessories, round tiles, 2 Nos Hot Dipped Galvanized M.S Modularbox of 1.2 mm thickwith earth terminal,2 Nos10 A two way Modular switch, 3 pin ceiling rose / holder / 3 way connector ,Modular face plate with grid plate,screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR 6 Medium point (up to 6 mtr.) 7 Long point(up to 10 mtr.) 8 Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal sizeFR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) inrecessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & its ISI marked (IS:3419-1988)accessories, Hot Dipped GalvanizedModular box of 1.2 mm thick with earth terminal, 10 A modularswitch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR 9 On board 10 Supplying and fixing of power plug point with Modular accessories as per PWD specification for electrical Works, on hot dipped galvanized modular box of 1.2 mm thick with earthing terminal/connector on surface or in recessed with suitable size of modular face place with grid plate and cover plate including cost ofISI marked modular 16 amp. Switch (IS :3854) and 6/16 amp. socket outlet (IS:1293) making connection , testing , etc. as required. For specification ofWiring accessories refer ChapterE - 07related item & For additional technical parameters of product / work refer Annexure A attached with this BSR 11 S&F following sizes (dia.) of ISI marked virgin material MMS ( IS:9537 P - III ) PVC conduit along withISI marked (IS:3419-1988) accessories as requiredinrecessincludingcutting the wall, covering conduit and making good the same as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 12 20 mm 13 25 mm 14 32 mm 15 Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 forlower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5,in existingsurface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure A attached with this BSR 16 1 x 1.5 sq.mm 17 2 x 2.5 sq. mm. + 1x1.5sqmm 18 2 x 4.0 sq. mm. + 1 x 2.5 sq. mm. 19 2 x 6.0 sq. mm. + 1 x 2.5 sq. mm. 20 1 x 4.0 sq.mm 21 4 x 6.0 sq.mm 22 4 x 10.0 sq.mm 23 Providing & Fixing of ISI marked surface type buzzer (IS:2268-1994) with CM/L no. printed including making connection testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 24 P & F phenolic laminated sheet 2.0 mm thick of following size . Including screws, cup washer as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 25 75 mm dia 26 P & F 1.2mm thickM.S. Recessed fan box, hexagonal/ round of size 130 mm dia, depth 75mm,12 mm dia rod fan hook with 100 mmlength extended on each side . All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure A attached with this BSR 27 Providing & Fixing of modular type 120 W Step Fan regulator duly ISI marked (IS 11037:1984 ) with CM/L no. printedmade out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating ,includingall as per pre approved by Engineer in charge,making connections, testing etc. as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 28 5 step fan regulator 2 Module 360 dgree rotating 29 Providing & Fixing of following modular accessories as per PWD specification for electrical Works,made out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating , includingall as per pre approved by Engineer in charge,making connections, testing etc. as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 30 Blanking plate 31 25 Amp. 2 Module Motor Starter with on / off Push button 32 Providing & Fixing of modular type lockable feature socket dulymade out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating , includingall as per pre approved by Engineer in charge,making connections, testing etc. as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 33 25 Amp. 2 Module Socket 34 Providing & Fixing ofextra down rod of 15 mm dia . ERW (Electrical resistance welded ) of 1.6mm nominal thick medium duty steelpipe including cutting, threading, drilling, fixing quarter pin etc as reqd.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 35 P & F of Gravity Louver shutter of superior quality made out of frame of18 swg M.S. sheet & Louvers made from 24 swg MS Sheetwith enamel paint including cost of nuts, bolts, etc as reqd.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 36 Up to 380 mm size 37 Supplying and drawing PE Insulated & PVC Sheathed unarmoured telephone cable with 0.5 mm dia. Solid Annealed electrolytic grade bare Copper Conductor as per IS: 8130/84 &confirming to TEC specification GR / WIR/06-03 March 2002in existingsurface or recessed conduit/casing capping. including ferruling on each pair for Identification etc. as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 38 3 pair 39 5 pair 40 50 pair 41 20 pair 42 P & F Krone module with base framein the recess / surface made out of 1.2 mm thicksheet steel box, front openable, having locking arrangements duly powder painted,including dressing, ferrulingandpunchingof telephone cable with krone tool etc. as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 43 20 Pairs 44 50 Pairs 45 P & F 1.2 mm thickG. I. / M .S. Sheet boxes duly finished with two coats of red oxide and with earthing terminal of following sizes (nominal size) in recessed/surface as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 46 1.2 mm thickM. S. Sheet boxes 47 175mm x 100mm x 60mm 48 P & F paper phenolic resin bondedlaminates confirming to IS : 2036 -1995 for boxes/ frames including making holes for switches etc, with brass screws, washers/ zinc platednut and bolts as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 49 3.0 mm thick 50 Providing & Fixing of flush typenon modular single line telephone jackmade out fromindustrial grade Polycarbonate or fire resistant ABS material, including making connection testing etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 51 Supply, Drawing and Testing of 4 pair, 23 AWG Solid Bare Copper wire insulated with PVC, UTP (Unshielded Twisted Pair), Category 6, Class E, 100 Ohm Impedance, Indoor Cable as per latest ammendments of ANSI/TIA/EIA-568 , The copper conductors should be balanced twisted in pairs, seperated by a cross-member fluted pair divider & protected byPVC Jacket. Certified performance in a 4-connector configuration upto 100 Mtrs channel requirements & transmission frequencies up to 250 Mhz. in existing MS/PVC Conduits/casing capping including making connections to Information outlets and Patch Panels with jack &ferruling at both ends for identification with necessary tools for punching, stripping, crimping and testing etc as required complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 52 Supply and Installation of unsheilded/360 degree sheilded Information outlets made of high impact plastic body with ABS, FR Grade halogen free material with provision for protection against dust in jack, suitable for Cat 6/6A application complying to latest ammendments, According. to Cat. 6/6A channel, It should support channel as well as components requirements of Cat.6/6A standards at frequencies of up to 250 to 500 Mhz. Cat 6/6A unshielded/shielded Jack should be suitable to terminate 4 pair, 23/24 AWG solid/stranded wire diameters, using 100 Ohm unshielded/shielded balance twisted pair cable, the jack should have tooless/impact termination on reliable copper tin plated Insulation displacement contact, with easy lock mechanism, It supports IEC 60603-7-4 and complied with ANSI/TIA/EIA 568 C.2 standard. jack should be RJ11,RJ12 & RJ45 compatible. Should support Ethernet 1.2 Gb/s ATM,Digital video and broadband/baseband analog video, Voice over internet protocal (VOIP) Specifications in existing modular/MS Boxes along with necessory connections as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 53 Cat 6, Un-sheilded Information Outlet 54 Supply & fixing of square Faceplate for Flush / Surface Mount Information Outlets Single/Dual or Quad Aperture ,material should bePC+ABS body, Suitable for RJ45 unshielded/shielded connection modules. Should match with I. O. OEM. Dimensions should be 86mm X 86mm as required complete in all respect.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 55 Single Aperture 56 Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load andsite requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting ofclass 3 as per IEC,minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted inexisting distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above ratingincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 57 Single pole MCB (With B/C curve tripping Characteristics) 58 6 A to 32 A rating 59 Triple pole MCB(With B/C curve trippingCharacteristics) 60 6 A to 32 A rating 61 50/63 A rating 62 Four pole MCB (With B/C curve tripping Characteristics) 63 6 A to 32 A rating 64 50/63 A rating 65 Providing & Fixing of Recessed/surface mounting heavy duty horizontal type Double Door ( Metal / Glazed )Distribution board with Metal end box made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3, powder painted complete with reversible door (for double door DB only )100 amp. insulated copper bus bar/shorting link , copper neutral link, copper earth link , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, Ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 66 Metal door (Three phase) Per phase isolation, Horizontal IK-09 and IP-43 with Metal end box 67 6Way(Incomer 8,Sub Incomer2+2+2) 68 8Way(Incomer 8,Sub Incomer2+2+2) 69 Providing & Fixing of 240/415 V Residual current circuit breaker (RCCB) conforming to (IS:12640-1)/ IEC 61008 -1 , rated 4 KV impulse withstand voltage truly current operated and shall operate on CBCT mechanisum, provision for pad lock,min. operation 10,000 upto 63 A rating and5000 for 100 Aratingand minimum phase termination capacity of 35 sq.mm. rigid wire, IP 20 contact protection with existing distribution board / sheetincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 70 Two pole 100/300mA sensitivity 71 63 A rating 72 Providing & Fixing of Recessed/surface mounting heavy duty Vertical TPN Distribution board with Metal end box with provision of incomer suitable for 3/4 pole MCCB and SP / TP MCB as outgoing ,made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3. powder painted with reversible door (for double door DB only ) complete with insulated 160 (upto 160 A Incomer) / 250 Amp. copper bus bar, neutral bars with shrouds, earth bar , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure A attached with this BSR 73 Double door IP-43 & IK-09 with Provision of Incomer MCCB 160 A Rating with Metal end box 74 6 Way 75 Supplyandinstallationofhigh tensile low carbon steel rod molecularly bonded with 99.9 % Copperthickness (250 microns) andconfirming toUL 467, IS/IEC 62561-2of following size and length and as per point mentioned (a), (b), [c), (d), (e) below :- 76 (a) Bore a hole of dia. 100 mm of required length, Place the rod in the centre of Hole 77 (b)filled with anti corrosiveconductivecompounds with the permanent sealings at both the ends, CPRI/ ERDAtested with RMS capacity of minimum 30 KA for withstanding 1 second .To ensure the moisture content and electrical conductivity, 25 kg for 2000 mm & 50 Kgs for 3000mm of resistance lowering earth enhancement material shall be used as a backfill compound. The compound shall be tested form NABL acredeated labfor lowresistivity ( less than 0.12 Ohm - meter ) & high conductivity in nature with carbon as a major contentas per referance of IS 3043-1987,IEEE 80-2013 (clause 14.5d) , IEEE 837 & IER 1956 with latest amendemnts 78 © Connect the rod with copper Strip/Conductor/Wire with suitable clamp made from tinned copper and SS 304 Bolt 79 (d) Place Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height250 to 300 mm. 80 (d)Testing of earth resistance for value of 5 ohms or lessas required & must record by engineer in charge during site visit and ensure to enter in measurment book. 81 (e) Test certificatesfor confirming above standards from OEM is mandatory. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 82 17.2 mm thick and 3 Mtr. Long 83 Plate Earthing as per IS:3043 withcopper Earth plate of purity >95% of size 600mm x 600mm x 3.0mm by embodying3 mtr. below the ground level with 20mm dia. G.I. B class watering Pipe ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height250 to 300 mm. and embodying the pipecomplete with alternate layers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or lessas required & must record by engineer in charge during site visit and ensure to enter in measurment book. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 84 Supply & Laying following size earth stripin horizontal or vertical run in surface by means of Earth strip DMC Insulatorincluding riveting/ soldering/ welding, Jointing shall be done by overlapping and with 2 set of Brass (for Cu strip) / GI (for GI Strip) nut bolt & spring washer spaced at 50cm making connection etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 85 25mm x 3mm copper strip 86 25mm x 3mm G.I. ( Hot Dipped) Strip 87 Providing & Fixing ofBEEStar rated copper wounded double ball bearing capacitor start, aluminium body & Metallicblade ceilingfanConforming to all the performance requirements laid down in IS 374:2019 including all amendments, as applicable ; & Carry BIS licensing (i.e. ISI marking) with down rod up to 80 cm with secondary support safety cable ( steel rope) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 88 1200 mm Sweep BEE 1 Star rated (service value >=4.0 to < 4.5 ) 89 Providing & Fixing of Heavy duty capacitor start, copper woundDouble ball bearing900/1400 RPM single phaseExhaustfan conforming to IS:2312 ISI marked in existing opening including making connections testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 90 300 mm sweep(900/1400 RPM) 91 Providing & Fixing ofof Double ball bearing, copper wounded capacitor startsingle phase metallicblade fresh air fan, in existing opening including cost of hardware , flexible 3 core copper conductor ,making connections, testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 92 225 mm sweep 93 Providing & Fixing of 450 mm SweepOscillating type Wall mounting / Pedestal typefans with Three speed, ON andOFF position, Sintered Iron bush oil impregnated,with metal front and back 120 or moreribs guard; Three no. Aluminiumblades, minimum Air delivery 100 Cum. / Minute , Minimum Service Value 1.11 Cum./min/watt, noise level should be <= 75 dB, power consumption <= 120 watts, motor protection through thermal overload protection device, including fixing with anchor bolts, making connection testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 94 Wall mounting type with Adjustable Vertical Angle 95 Providing & Fixing of IP20 SMD Mid Power LED batten type integrated light fixture made from Powder coated Extruded aluminiumhousing with in built driver, System lumen efficacy ≥ 110 lm/Watt output, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, CRI >80 , life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , Maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 96 1170mm(+/-10%) LED batten with min. lumen output 2200 lm 97 Providing & Fixing of IP20, 2x2 LED Surface/ Recessedmounting Mid power SMD type LED Light fixture not less than 50mm housing depth made from CRCA sheet steel housing, high purity / transmisivity UV stabilized Non -yellowish diffuser for uniform light distribution. High efficiency with 4 KV internal/external surge protection BIS certified isolated driver having efficiency > 85% , with Short & Open circuit protection(Integral with light fixture). System lumen efficacy of ≥ 120 lm/Watt ,THD < 10 % , p.f.≥0.95,CRI >80 ,life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. 98 OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted.All as per pre approved by Engineer in charge. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 99 Surface Moutning 100 Minimum lumen output 3600 lm 101 Providing & Fixing of IP-20 LED Recessed / Surface Mounted, Round / SqaureSMD Mid Power LED Downlight with power coated die-cast aluminum housingwith UV Stabilized non yellowish Diffuser withBIS complience 2.5 KV surge protected Isolated driver, with Short & Open circuit protection, having efficiency > 85% . System Lumen efficacy of ≥ 110 lm / watt, THD < 10 % , Pf.≥0.95, CRI >80,life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. 102 OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 103 Surface Mounting (with extruded alumn. Housing ) 104 Minimum lumen output 1950 lm 105 Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed ArrmouredAluminiumcable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV withH4- Grade electrolyticaluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) includingtesting etc. as required of following size. OEM must have its own in house NABL accrediated Laboratory for testing procedure as per IS:10810.For additional technical parameters of product / work refer Annexure A attached with this BSR 106 6.0 Sq. mm 107 4 core 108 10.0 Sq. mm 109 4 core 110 16.0 Sq. mm 111 4 core 112 25.0 Sq. mm 113 3.5 core 114 50.0 Sq. mm 115 3.5 core 116 70.0 Sq. mm 117 3.5 core 118 Supplying and making one end termination with Nickel plated heavy duty brass single compression gland (as per IS 12943-1990)) SIBG type consisting of Check Nut, Gland Body, Metal Washer(3 Nos.), Outer Seal Rubber Ring,Compression Nut,heavy duty aluminium lugs (as per IS 8309 -1993) duly crimped with crimping tool, PVC tape as perIS 8337-1976offollowing size ofPVC insulated & PVC sheathed/ XLPE aluminium conductor cable of 1100 volt grade as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 119 4 x 6.0 sq.mm 120 4 x 10.0 sq.mm 121 4 x 16.0 sq.mm 122 3.5 x 70.0 sq.mm 123 3.5 x 50.0 sq.mm 124 SITC of IP-42 and general construction confirming to IS:8623 : 1993, wall/ free standing floor mounted dust and vermin proof compartmentalisedcubical panel as specifications andOther parameters requiredas per point (a) ,(b), (c),(d), (e), (f), (g), (h) as below:- 125 (a)Thickness of CRCA sheet shallbe 2.0 mm,cable alley compartments having concealed hinged type doors with key type lock with / withoutdetachable extension type structure. Removable 3 mm. thick sheet steel gland plates with appropriate size of knockouts for cables shall be provided 126 (b)complete panel shall undergo a process of degreasing, Water rinsing, Activation, derusting,pickling in acid bath, phosphatising & shall be subjected to nine tank process and then Powder coated with approved shade of minimum 70 microns on both side of panel.The panel having PE foam/ Neoprene rubber gasket of not less than 3mm thickness ,required hardware , concealed hinged door with key type locking arrangement for equipment/switchgear earthed with 2.5 sq.mm braided copper wire. 127 [c)Interconnection between bus bar and switchgears /cable shall be rigidly supported and made out by flexible copper wires (up to 63 amp ) and by solid bus bar(>63 amp ) . control wiring will be carried out with 1.5 Sq.mm, Earth wire with 2.5 Sq.mm and CT with 2.5 sq.mm flexible copper wire only.All joints / interconnections of copper bus bar shall be dully tinned . Clearance between main bus bar and risers / metal parts shall be at least 10 mm additional to width of bus bar Bus bar is insulated by Heat Shrinkable sleeves . Earth and Neutral bus bar shall be half of the size of phase bus bar. ( Cost of Bus bar/ Flexible wire for Interconnection between Main busbar and Switchgearis to be Paid Extra ) 128 (d)Wiring between components within switchgear and Incoming / outgoing cableshall be done through the terminal block only. Direct connection shall not be permitted. Each terminal block shall be one piece moulded, barrier type, 650 volt grade, complete with washers, heads, studs with two nuts and identification strips and shall have adequate continuous current rating. For tap-offs, adjacent terminals with shorting strips shall be used. 10% Spare terminal blocks shall be provided. Wire identification on marking strip shall correspond to the designation of the wiring diagrams. All wire terminals on the equipment shall also be marked with designation corresponding to those of the wiring diagram. 129 (e)All wiring shall be enclosed in plastic channels and neatly bunched and closed in metering chamber, Wiring between terminals of various devices shall be ‘point to point’ (no wire splitting or tee connections) with wires neatly trucked along the back of the panels, adequately supported to prevent sagging. 130 (f)Floor mounted panel shall be mounted on Base frame of ISMCchannel size 100 x 50 x 5 mm( to be paid Extra ) 131 (g) Tests: The insulation resistance (with 1000 V Megger) and High voltage Power frequency test (by applying a voltage of 2.5KV for one minute) shall be measured between phases, between phase and neutral and between phase and earth. both before and after high voltage power frequency test. The insulation resistance shall not be less than three megaohm. CT Secondary current injection test shall also be carried out. 132 (h) only outer surface area on all sides shall be measured & panel to be fabricated only from CPRI approved fabricator only (CPRI Test certificates to be submitted)All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 133 Supplying and fixing of Aluminium (IEC 60105 ISO 209-1,2) / Copper (IEC 60028) bus bar by means of SMC / DMC type insulatorwith standard short circuit withstand capacity, high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable PVC sleeves. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 134 Electrolytic grade Aluminium bus bar 6010 grade 135 Providing & Fixing of IS: 13875 & IEC :61326 confirming LED Digital type(up to 500) V range Volt meter / Direct- Ammeter /CT oertated ammeter/ Frequency meter / KWH meter / Multi Function Meter / Power analyzer of class 1 accuracyas per IS : 1248 of size 96mm x 96 mm including making connection by PVC insulated copper conductor with PVC sleeves / channel etc. as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 136 Three phase Ammeterwith Inbuilt Selector Switch 137 Three phase Voltmeter with Inbuilt Selector Switch 138 Providing & Fixing of BIS approvedCurrent Transformeras per PWD specification for electrical Works ,ISI marked as perIS 2705-1992/ conforming to IEC 60044-1, with secondary terminalof CT shall be brought out suitable to a terminal block which shall be easier accessible for testing and terminal connection , with all necessary support in existing panel including connection etc. as requiredCurrent transformer Ring Type Tape Wound/Resin Cast Wound as per IS 16227 with, Accuracy Cl, CT ratio and burden as specified. ISF<=5, Cu cross section of secondary wire 1.5sqmm (minimum), including all necessary support in existing panel including connection etc. as required . All as per pre approved by Engineer in charge.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 139 Ring type tape wound CT 140 C T Class 1, Ratio upto 150/5, Burden 5 VA 141 C T Class 1, Ratio 200/5 to 300/5, Burden 10 VA 142 Providing & Fixing of110/220 V, unibody LED Indicatinglamp IEC 60947with integral circuit, IP 65 above panel &IP 20 terminal block, Approx. body dia for panel not less then 20 mm, length min. 50mm, front LED cover dia min.29 mm, contact material phospher bronze for Led, PCB contacts shall be ofbrass (tin plated), impulsedielectric tested for 2.5 KV, Rated insulation resistance shall be 100 M ohm at 500VDCincluding connection etc. as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 143 Red/yellow/Green colour 144 Providing & Fixing of Electricalinsulating rubber matts as per PWD specification for electrical Works, ISI marked confirming to IS: 15652 /2006with one sideanti skid abberation marks and pasting the mat with synthetic rubber adhesive as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 145 11 KV,Class B 2.5 mm thick with proof voltage 22 KV AC (rms) and Break Down Voltage45 KV AC (rms) 146 Providing & Fixing of self healing IP20 MPP type shunt capacitor (banks) conforming to IS:13340-41 /IEC :831-1&2 OR IEC : 60831-1& 2 in existing panel or parallel with load terminals , the capacitor shall be fitted with discharge resistors, pressure sensitive disconnector ( PSD ) and shall have dissipation factor less than 0.0025 at 50 Hz, Operating loss less than 0.30 Watt per KVAR. Min over current capacity 1.8 times rated current & peak inrush current min. 300 times of rated current, llife expectancy greater than 100000hrs(temp class - 25 D)in 440 V/480 V Capacitor and for 525 V should life expectancy minimum 1,65,000 hrs (temp class - 25 D)including making connections, testing etc. as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 147 Heavy dutyThree phase 480 V, 50 Hzcylindrical type capacitor (Bank) 148 Providing & Fixing of IP54 microprocessor based 3 CT’s for all 3 phasesensing compensationpower factor correction relay Size 139mm x 139 mm, Operating Voltage 415/440 V, IEC / EN 61000-6-(2&4)having 3 CT sensing, sensitivity up to 50 milli amp secondary current , self analysing auto c/k setting according to targeted power factor setting, the relay shall havedigit display unit for display of real power factor, targeted power factor, lag/lead capacitor switching status, alarm output for under current, over current, insufficient compensation, communication interface with RS 485,indication of switching on units, auto/manual status, and shall have over load protection, no volt release , having multi parameter like KW, KVA, KVAR, RMS Value, step switching time 2 sec to 1800 sec. Lead & Lag parameters, metering facility and3 no. Class- 0.5 Cast ResinCT ( refer CT specs in this chapter )for sensing the relay including making coonection with 1.5 Sq.mm copper wire etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 149 6 to 8 stage 150 Providing & Fixing of440 Volt 3 pole capacitor(AC 6 B ) duty contactor with 3 no. early make and post break auxiliary contacts in series with quick discharge damping resistors/ reactors to limit the inrush current as per PWD specification for electrical Works,IS/IEC 60947-4-1 : 2000, insulation voltage 1000V, impulse withstand voltage 8 KV,Din rail mounting type including making connections, testing etc. as required. suitable for following capacity capacitor bank.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 151 up to 6 KVAR 152 10 KVAR 153 SITC of3 /4pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant materialhaving following current rating, short circuitbreaking capacityat 440/415 V, 50 Hz; O/L & S/C settings , conforming to IS/IEC 60947 P -2 :2003 with frontface and centralised adjustable, trip free mechanisum, true contact position indicator,line load interchangeability,designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree,pollution degree 3, having positive isolation capability, push(test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% Icu. U imp =8 KV, rated insulation voltage690 V.provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connectionsetc. as required.OEM shall have submitNABL / CPRI / ERDA accrediated lab type test certificate before execution All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 154 3 pole MCCB With Thermal Magnetic release 155 up to 100 Amp , 25 kA, adjustable O/L & adjustable S/C setting, 156 SITC of3 /4pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant materialhaving following current rating, short circuitbreaking capacityat 440/415 V, 50 Hz; O/L & S/C settings , conforming to IS/IEC 60947 P -2 :2003 with frontface and centralised adjustable, trip free mechanisum, true contact position indicator,line load interchangeability,designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree,pollution degree 3, having positive isolation capability, push(test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% Icu. U imp =8 KV, rated insulation voltage690 V.provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connectionsetc. as required.OEM shall have submitNABL / CPRI / ERDA accrediated lab type test certificate before execution All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 157 4 pole MCCB With Thermal Magnetic release 158 up to 100 Amp , 25 kA, adjustable O/L & adjustable S/C setting, 159 160 Amp , 25 kA, adjustable O/L & adjustable S/C setting, 160 250 Amp , 35 kA, adjustable O/L & adjustable S/C setting, 161 Providing & Fixing of IK08, IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminummaterial with heat dissipation fins on housing with UV stabilized PC (UV stablization report submitted for UV cover ) /Toughened Glass coverand secondary lens on each LED & should be SMD type of 3 to 5 watt each . The System efficacy >=125 lm/ wt and potted driver& has a unique BIS R number withInput Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety , Power Factor >0.95 driverEfficiency >85%,THD(I) <10%Humidity 10% to 90% RH Working Temp -5C to 45C .driver current <750mA. The luminaireshall be BIS certified and Trade mark certified. Life ExpectancyEqual or more than 50000 burning hrs with Minimum 70% lumen maintened , CRI >70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external inside driver compartment. driver should be Phase to phase protection of 440 V for 4 Hrs.Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities forLED fixtures.(LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 162 LED Street Light fixture with Minimum lumen output 3700 lm 163 LED Street Light fixture with Minimum lumen output 8700 lm 164 Providing & Fixing of Street light bracket made out from following size of B class , Medium class G.I. Pipe confirming to IS : 1239 P - 1 ( 2004 ) with heavy duty pole clamp, Saddles suitable fastners etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 165 SITC of Single Stage, water cooled, High Speed (2880 RPM), Horizontal, Centrifugal, Openwell Submersible pumps set pre filled with coolent water and fitted with mechanical seal - T/C Vs T/C, Thrust bearing shall be ofcarbon + S.S.The stator body of single phase pumpshall be of SS and rest of all shall be of cast iron. All casting parts should be cathod electro deposition (CED) coated and other construction material should be confirming to IS : 14220: 2018 . The overall performance of pump shall confirm to BEE energy efficiency level of 3 star. Valid BEE certificate from OEM must be submitted for the same. Motor should be IE2 class as per IEC 60034-2-1: 2007, IEC 60034-30: 2008,& IS12615:2011, including making connection etc as required complete in all respect. OEM shall have submitNABL / CPRI / ERDA accrediatedlab type test certificate before execution. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 166 1.5 HP, 1-Ø, (18 -26) Mtr, (126 - 78) LPM 167 Supply & fixing of GI pipes confirming to IS : 1239 P - 1 ( 2004 ) with flanges duly screwed & welded including rubber washer, nuts & bolts of 8mm dia complete in all respect.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 168 B class 50mm dia 169 SITC of ContactorOEM Fabricated DOL/Star-Delta Starter panel with switchgear selection as per Type-2 Cordinatiom Chart andmade out from 1.6 mm thick powder coated CRCA sheet, enclosure comprising of over load protection relay, short circuit & single phasing protection, Illuminated ON / OFFpush buttons,ammeter, voltmeter, indicating lamps etc.suitable for following rating motors complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 170 For Three phase Submersible / Mono block pump 171 3.0 HP to 5.0 HP ( Star / Delta starter ) 172 P/Laying ISI marked P.V.C. insulated submersible cable confirming to(IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from99.90 % purity copper, stranding in acc. to IS:8130/IEC 60228 forlower watt loss , oxygen freefor less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5,existing pipe / open trench / Cable tray / on surface including making connection etc. as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 173 6.0 Sq.mm 3 core flat / Round 174 Supply, Fabricating & installing following sizes of perforated Hot dipped Galvanized iron cable tray ( Galvanized thickness not less then 50 microns) with perforation not more then 17.5% in convenient section including horizontal and vertical bends, reducers tees,cross members and other accessories as required and duly suspended from the ceiling with GI suspenders including GI bolts & nuts , fastners, supports etc. as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 175 150mm x 50mm x 1.6mm 176 P & F in position frame made out of M.S. angle (riveted or welded) finished with two coats of red oxide and two coats enamel paint including cutting, welding, holes etc.of following sizes as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 177 50mm x 50mm x 6mm 178 35mm x 35mm x 5mm 179 Providing & Fixing ofCam operated rotary (Auto/manual) switches on existing panel with 2 way and off position using high grade engineering materialto international standards with cam assemblyinsulation of glass filled polyamide with high tracking index. For reliable and stable electrical and mechanical endurance double butt contacts with silver bi-metal on copper should provided . contact assembly is of operating temp range -25 degree C to 55 degree C, frequency upto 10 KHz. switch life under std. op. conditions shall be mechanically minimum 50000 operations @300 cycles/ hour and electrically 10,000 operations at 100% rated duty for 100 cycles/ hour including making connection etc.as required . All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 180 10 AMP 181 32 AMP 182 Providing & Fixing of ISO certified company made on load change over switch, front handle operated, four pole 415 V as per PWD specificationfor electrical Works conforming to IS/lEC 60947-3 : 1999 including connections , testing etc. as required .in the following rating.Appropriate type test certificate / OEM test report shall be submitted .All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 183 Open execution type 184 125 A 185 Supply and erection ofGalvanized Iron pole with galvanizing done in single dipping (Average coating thickness Minimum 65 Microns) continuously tapered poles having Octagonal / Circular cross-sections designed to withstand the maximum wind speed as per IS 875, The pole shaft shall be made from sheet steel (HT Steel Conforming to grade S355JO) and confirming to BSEN 10025 and shall be continuously tapered with single longitudinal welding. There shall not be any circumferential welding. The welding of pole shaft shall be done by Submerged Arc Welding (SAW) process. pole shafts shall be provided with the rigid flange plate of suitable thickness (Fe 410 conforming to IS 226 / IS 2062) with provision for fixing 4 no. foundation bolts, This base plate shall be fillet welded to the pole shaft at two locations i.e. from inside and outside.The octagonal Poles shall have lockable door of approximate 500 mm length at the elevation of 500 mm from the Base plate with bakelite sheet having 6A SP MCB and 16 sqmm stud type connector ( 4 nos) inside the pole at door opening for cable connection of following length and dimension as per table P-01 with base plate and foundation bolt on the Existing cement concrete foundation.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 186 Poles with Octagonal Cross Section 187 7 Mtr. 188 Providing and fixing of IP 65 protected Polycarbonate / Polysterene fuse box moulded with inside knock outs of following size with hinged cover, transparent window,PU gasket, locking arrangement, duly holded with 2 nos. pole clamps of 20 mm x 3 mm flat with nut and bolts, The box shall be provided with Din rail, 4 / 8 way 10.0 / 16.0sq.mm heavy duty connector, earth terminal,complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 189 160 mm X 225 mm X 100 mm 190 Providing and fixing welded mesh/expanded metal mesh 25 mmx 25 mm x 3mm in frame work, flat iron beading 20x3mm including top cross laps inside and out sides welding, iron bolts, crews, clips etc. including two coat of red oxide and two coat of enamel paint or more requiredcomplete with frame work with 50 X 50 X 6mm angle iron post 30 cm in ground embeded in cement concrete 1:3:6 (30X30X45cm) at corner and every three mtr including painting with one coat of primer and two coat of enamel paint work will be done as per direction of engineer incharge of sizecomplete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 191 Providing & Fixing offollowing size mounting grid plates with cover plates made from fire retardent UV established high performance engineering plastic suitable for all universal metal boxes for front installation & removal direct fit type complete in all respect.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 192 1/2 Module 193 3 Module 194 Providing & Fixing ofWiring Accessories OEM fabricated following size GI box of 1.2 mm thick with earthing terminal and adjustable floating clamp in recess/ surface suitable for modular accessories as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 195 1-2 Module 196 3 Module 197 Providing & Fixing of Vertical(BEE 5 star rated) / Horizontal( BEE 3 star rated) storage water heater with outer casing made of Engineering Plastic sheet (Upto 25 Ltr) / Metal rust proof Body (35 & 50 Ltr), Glass - line / Titanium Enamel coated Pressure Pump Compatible 8 bar pressure Inner tank, Glass Line Coated , mineral filled heating element, stem type, snap actionadjustable thermostat , Dual indicating lampsInjected PUF insulation, Multi Function Valve etc. as required held in position with 2/4 no. 10/12 mm anchor Fastener, duly wired with 3 core 2.5/4.0 Sqmm PVC insulated & sheathed copper conductor and 16 A/25A three pin plug top with Portable Residual Current Device ( PRCD ) , including making inlet, outlet Flexible alloyconnection, testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 198 15 Ltr. 199 Supply and Fixing of Pole OEM fabricated hot dipped galvanised M.S. Overhang (48.3 X 3.25 mm) with cap (400 x 88.9 / 114.3 x 3.25 mm) over the existing poles. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 200 Single arm overhang 201 SITC of Radiator Cooled and Turbo charged Silent DG Set (As per latest CPCB emissionnorms) havingspecifications as per A, B, C, D, E, F,G,H & I 202 A) 1500 RPM Diesel Engine conforming to BS:649/5514 of suitable BHP(up to 82.5 kVA 6 cylinder or Below required, 125 kVA & Above ratings 6 cylinder or aboverequired ) capable of taking 10% over loading for one hour after 12 hours of continuous operation.,Dry exhaust mainfold with Hospital grade silencer and catalytic convertor(isolated from main DG chamber),up to 3 M exhaust piping (with LRB insulation & Alum. cladding ) as required . 203 B)AC Brush less SPDP Alternator conform to BS 5000 (part 99) or IS/IEC 60034-1. . Alternator shall be self regulated with standard Alternator Protection( Over voltage , over speed & under voltage, under speed warning & shutdown).Engine & Alternator mounted on a common base Frame & coupled through a flexible coupling or close coupled 204 C) CPCB / ARAI approved Standard canopy with Weatherproof, powdercoated Accoustic enclosure for DG set for sound attenuation fabricated from 1.6 mm CRCA sheet steel (structure) with sidewall fabricated from 1.6 mm CRCA sheet & filled with glasswool (96Kg/m3) / Foam. as per IS8183 the doors of 28/40/50/85mm thick as perrating and fabricated from 1.6mm CRCA sheet packed with accoustic material, All doors/opening are sealed with neoprene /EPDNgaskets. The DG Set has Inbuilt / External in fuel tank to run 6 to 8 Hrs as per OEM standard, with protection and tripping of DG set against temperature of more than 50 degree centigrade. 205 D) Electronic / Mechanical governor, Manual & electric Start ,Batteries with battry charger,Engine instruments panel,AVM pads All controls for operation of DG set are from outside the enclosure with DG control panel having Microprocessor based Genset monitoring like Running Hour, RPM, Low Lube Oil tripping & control system, Panel mounted MCCB/ACB of suitable rating, Ammeter, Voltmeter, PF meter, frequency meter, KWH meter,digital fuel display meter, Ind.lamps etc. mounted inside enclosure , visible and accessible from outside. The enclosure should be suitable for following capacity DG sets and alternator. Noise level shall be less than 75 dB at a distance of 1 Mtrs. duly certified by authorised agency etc. complete in all respect of following capacity : 206 E) (i) Accoustic glass wool wall thickness should not be less then 40mm and not less then 20mm PU foam upto rating 100 KVA. (ii).Accoustic glass wool wall thickness should not be less then 65mm and not less then 50mm PU foam upto rating 250 KVA. (iii)Accoustic glass wool wall thickness should not be less then 100mm forrating above 250 KVA. 207 F) First filling of the fuel tank shall be done by contractor and the prevailing fuel cost at that time shall be reimbursed to the contactor by department. 208 G) Servicing Contract of DG Set from OEMs Authorised Service Dealer as per OEM guidelines during the DLP period shall be done by contractor including all consumables, actual charges shall be reimbursed to the contractor by End User Department. 209 H) Manufacturer / OEM must have its authorized service dealer in Rajasthan. Which can provide service within 6 Hours of compalint registration. 210 I) DG set will be offered for Inspection and Testing at Manufacturers Works in presence of Departmental Engineers. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 211 50 KVA at 0.8 pf 415V 50Hz 3-ǿ 212 SITC of PLC Based Auto main failure (AMF) Panel fabricated from CRCA sheet steel 2 mmThick , Powder coated finish , Engine Start & Stopcommands, control Relays , Ammeter & Voltmeterwith selector switches, Control & 2 nos 4 pole Power Contactors with 2 no. of required size 4 pole MCCB, Timers, Electronic Hooter ,Visual & Alarm indication for faults, UPS, operator interface panel complete in all respect suitable for following capacity DG sets: Appropriate Test Certificate/ report of product/accessories from OEM/Panel Manufecturer shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 213 50 to 82.5 KVA 214 Supply & Laying following size earth wire in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles,making connection with GI/Cu purity purity >95%thimble etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 215 8 SWG copper Wire 216 Providing, Fixing, Jointing, Testing & Commissioning of Medium duty MS B class pipes conforming to IS 3589 / 1239 part-I for DG Exhaust applications (beyond 1.5 Mtr. length)includingcutting,welding etc & fittings like elbows,flanges, tapers, reducer, gaskets etc. fixing the pipe on the wall/ceiling with suitable clamps, hanger and nuts bolts . including the cost of thermal insulation with 50 mm thick layers of LRB rock wool as per IS : 8183-1993 (64 kg/m3 density) & 26 SWG aluminium sheet claddings etc complete as required complete in all respect.(Cost of Steel Structure for Exhaust pipe will be paid Extra). All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 217 125 mm dia 218 P & F of Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height250 to 300 mm.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 219 Supply, installation, testing & commissioning of following size & Material air termination rods confirming to IEC/EN 62561 with suitable OEM recommendedmounting arrangement on parapet wall all as per standard , complete as required. the test report accredited by third party accreditation body like VDE/ ILAC/ DAkkS/ UL/ NABL is to be submitted.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annex ure A attached with this BSR . 220 1500 mm long, 10 mm Dia. Aluminium / AlMgSi 221 Supply & Fixing Air-termination rod clamps for connecting air-termination rods with one or two conductors. Material of clamp Al, with clamping range of air-termination rod 10 / 16 mm and Clamping range of conductor Rd 2x 8-10 mm, & Complied as per Standard EN 62561-1, tested to carry from 100KA (10/350μs) lightning current the test report accredited by third party accreditation body like VDE/ILAC/ DAkkS/ UL/ NABL is to be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annex ure A attached with this BSR . 222 Supply and Fixing of stainless steel clamp for holding 8mm dia. conductor on Parapet Wall / Side Fl 20 mm, Height- 20 mm & Complied as per Standard EN 62561-4. With accessories SS Screw and Gitty etc. as required. the test report accredited by third party accreditation body like VDE/ILAC/ DAkkS/ UL/ NABL is to be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annex ure A attached with this BSR . 223 Supply & LayingofAluminum / SS / AlMgSi Round Conductor confirming to IEC/EN 62561 etc. as required. the test report accredited by third party accreditation body like VDE/ILAC/ DAkkS/ UL/ NABL is to be submitted. ( Supporting Clamps to be paid Extra )All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annex ure A attached with this BSR . 224 8 mm Dia. Aluminium conductor 225 Supply and Fixing of Test Joint (Folding Clamp) made of SS,suitable to connect 8mm round conductor with25 mm x 6 mm GI strip etc. as required. the test report accredited by third party accreditation body likeVDE/ILAC/ DAkkS/ UL/ NABL is to be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annex ure A attached with this BSR . 226 Supply, Installation, & Testing of 19 1U Rack Mounted/ surface mounted aluminum/ CRCA 1.2mm powder coated, Singlemode glass Fiber Optic Cable Patch panel/LIU loaded with flangless/screwable duplex adapters for ST/E-2000/SC/LC/MT-RJ/PC type, It should have easy removable Top plate with push buttons, there should be a splice tray installed in the Patch panel/LIU which can handle the fiber cores, splice tray should be PC+ABS material, it should include accessories like mounting hardware, gormetts, heat shrink tubes/sleevs, screws, nuts to install the panel for rack/wallmount applications as per requirment complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 227 24 Ports 228 Supply , Installation and Testing of 4 pair, 100 Ohm impedance, Cat 6/6A /Class E/Ea patch cords should be constructed of minimum 23/24 AWG, stranded bare Copper cable with FRPVC/LSZH Jacket, with an enhanced performance by factory moulded RJ45 connectors with strain relief boots as per ANSI/TIA/EIA 568-C.2 suitable for Cat 6/6A application complying to latest ammendments Category 6/6A Standards, According. to TIA568C.2, ISO/IEC 11801, EN 50173, IEC 60603-7-51, EN 60603-7, IEEE 802.3an minimum requirement for 1G BASE-T to 10G BASE-T performance. Patch cords shall be straight thru cable compatible with both T568-A and T568-B wiring schemes, should support IEEE 802.3af / IEEE 802.3at for POE applications, Minimum 750 to 1000 mating cycles in plug contacts for long durability, Should support Ethernet 10GBASE-T, 1.2 Gb/s ATM, Token ring 4/16, Digital video and broadband/baseband analog video, Voice over internet protocal (VOIP).All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 229 Cat 6, U/UTP (Unscreened/Un-sheilded Twisted Pair) Patch Cord 230 1 Mtr 231 Supply & Installation of IP-20 & IK-08 , UL ListedWall mounted Double Section Communication enclosure (Rack) made from powder coated (60 to 80 Micron) CRCA sheet, front sturdy sheet steel frame folded from one piece and welded with minimum 5mm toughened glass door,Vertical Mounting Rail 1.6 MM with UMarking , with All round protective channel on the door aperture, lock integrated on front door, top and bottom cover with cable entry provision with gland plates, integrated side walls, 2 pair of 19 angles with wall mounting provision on wall. Accessories like: 1 No of 19 1U Horizontal Cable manager, 1 No of 90 cfm 230V AC Fan with 1 mts long cable, mounting hardware , 1 No of 19 1U, mountable socket strips with 5 nos of 5A universal sockets with 2 mts long power chord for supplying power to switches, fans etc along with earth continuity kit, indicator, moulded power supply cable. fixing on wall with Suitable Anchor fastneretc as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 232 9 U Rackwith Width 600 mm & Depth 400 mm + 100 mm 233 Supply , Installation, Testing and Comissioning ofManaged Layer-2 Intelligent 10/100 Ethernet Switch providing 24 x 10/100/1000 MBPS Giga Ethernet ports / with min 2 SFP Giga Ports (provision for Fiber Giga connectivity) with related LAN Base Software including making connections etc as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 234 Supply , Installation, Testing and Comissioning ofInverter type Air Cooled Hi Wall split type Air conditioners with latest star rating system as per BEE amended upto date complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU), R-32/R-410 Green Refrigerant, wireless Remote control, suitable for working between 230V +/- 10% with low & high voltage cutoff and50 hz , single phaseACsupply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 235 1.5 TR ISEER not less then 3.8 236 2.0 TR ISEER not less then 3.8 237 Supply & fixing MS powder coated stand suitable for 1.0/1.5/ 2.0 Tr outdoor type of Split AC.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 238 Supply, Fixing and testing of following capacity ISO certified company made wall mounted stabilizer having output voltage variation from 200 V to 250 V(+/-5%) with input voltage variation from 170 V to 260 V, time delay facility from 2 to 4 minute and high cutoff at 270 V with providing of 16 Amp /20 Amp Industrialplug top making connection etc complete in all respect.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 239 4 kVA 240 5 kVA 241 Providing & Fixing of IS : 4985 - 2000 Class -4 (10 Kgf / Sqcm) UPVC drain water piping withfittings (IS:7834 & 10Kgf/sqcm) like elbow, socket, Tee, solvent cement jointing,support with MS hanger on ceiling or recessed in wallwith chasing & plastering with 6 mmthickclosedcellelastomeric nitrile rubberinsulation including leakage testing etc. as required of following Nominal sizes. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 242 25 mm 243 SITC of Interconnecting refrigerantcopper pipe forsplit/Ductable/ Casseette AC of DHE Grade C12200- ASTM B68, B75, chemical composition of copper %- 99.0 Min and Phosphorus %- 0.015 to 0.040 . For Annealed copper tube :- Tensile strength = 210 Mpa wih elongation % = 40 Min . Ink MarkBrand Printing on Hard Tubes should be present. Piping between each set of indoor & outdoor units of different sizesas per OEM requirement & specifications including class O Nitrile rubber sleeves, chase cutting, supports, making good the same with sand cement plaster etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 244 Supplying and drawing flexible / stranded bare copper conductor, PVC / XLPE insulated, overall aluminium mylar tape shielded ATC drain wire and outer PVC sheathed industrial Instrumentation (shielded)cables voltage grade 300/500 V as per BS /EN 50288-7 in existingsurface or recessed PVC/ MS conduit/casing capping/ Cable tray / Open Duct making connections, testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for cables. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 245 Armoured 246 4 core x 2.5 Sq.mm 247 Supply , Installation, Testing and Comissioning of IS:1475 marked self contained drinking water cooler withhermeticallysealed compressor,non CFC refrigerent suitable for operation on 230V/1pH/50Hz AC supply,Full stainless steel (SS304)body (0.8 mm thick)and tank (0.5 mm thick) , stainless steel water tray,minimum two nosBrass Chrome plated faucets and suitable drainage system complete in all respect with requiredheight MS fabricated and Painted Angle iron frame( Cost of frame to be paid Extra )complete in all respect of the following capacity.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 248 cooling capacity 150 Ltr./Hr. and storage capacity 150 Ltrs 249 Supply & Fixing of Dry Powder Agent (as per IS 4308:2019), ABC typeFire Extinguisher (Stored Pressure type) conforming to IS:15683:2018 , Powder coated Internal & External Surface Deep drawn cylinder body of Mild Steel CR2 grade conforming to IS: 513, Squeeze grip Forged brass release valve with Inbuilt safety release device, Diaphragm Type, 0 to 28 bar range pressure gauge, 450 mm long EPDM discharge tube, QR code for Product Traceability including Fixing on wall with suitable Anchor Fasteners as required of following capacity. Test Certificates of all the Parameters along with Hydro test & Burst test (For Cylinder Body) Certificatefrom OEM / External NABL Accrediated Lab is to be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 250 4 kg 251 Supply & Fixing of CO2 type Fire Extinguisher conforming to IS:15683:2018, charged with CO2 gas (purity 99.7% conforming to IS 15222), Powder coated Internal & External Surface Manganese steel ISI marked as per IS 7285 cylinder body , Wheel type Forged brass release valve ISI Marked as per IS 3224 with Inbuilt safety release device ((Fusible plug and Rupture Disc Type), 1.0 Mtr. Metal wire braided hose having minimum bursting pressure of 140 Kgf/cm2, Horn with metallic thread connection, QR code for Product Traceability,including Fixing on wall with suitable Anchor Fasteners as required of following capacity. Test Certificates of all the Parameters along with Hydro test & Burst test (For Cylinder Body) Certificatefrom OEM / External NABL Accrediated Lab is to be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 252 Capacity 4.5 Kg.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
34.
Drinking Water Supply and Sanitation #10236715 Price Bid
Augmentation Cum Reorganization Of Aapni Yojana Phase I Churu Bisau Feeder Water Supply Project Including 10 Years O And M District Churu.- 1 Part A : Cost Estimate For Pipeline Works 2 Earth Work In Excavation By Mechanical Means ( Hydraulic Excavator ) / Manual Means In Foundation Trenches Or Drains ( Not Exceeding 1.5 M In Width Or 10 Sqm On Plan ) Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Taking Out The Excavated Soil And Depositing And Refilling Of Jhiri With Watering & Ramming And Disposal Of Surplus Excavated Soil As Directed With In A Lead Of 50 Meter.All Kinds Of Soils 3 75 Mm Dia 4 90 Mm Dia 5 110 Mm Dia 6 125 Mm Dia 7 140 Mm Dia 8 160 Mm Dia 9 180 Mm Dia 10 200 Mm Dia 11 225 Mm Dia 12 100 Mm Dia 13 150 Mm Dia 14 200 Mm Dia 15 250 Mm Dia 16 300 Mm Dia 17 Providing, Lowering, Laying In Trenches, Aligning, Fixing In Position And Jointing Ductile Iron ( Di ) Isi Marked K-7 Grade S&S Pipes As Per 15:8329-2000 ( Amended Upto Date ) , With Internal Cement Mortar Lining Suitable For Potable Water With Rubber Ring ( Epdm ) Joints As Per Is: 5382- 1985 Including All Taxes ( Central And Local ) , Transportation And Freight Charges, Inspection Charges, Loading / I.I Unloading Charges, Including Cost Of Labour And Material, Specials ( Tee, Bend Etc. ) Satisfactory Hydraulic Testing, Disinfection Etc. Complete As Per Technical Specifications And Direction Of Engineer-In Charge. ( Excluding Earth Work ) Note : Providing And Fixing Of All Requisite Specials As Per Drawing, Design And Layout Are Inclusive In Rm Measurement Of The Item And Shall Not Be Paid Separately. 18 100 Mm Dia 19 150 Mm Dia 20 200 Mm Dia 21 250 Mm Dia 22 300 Mm Dia 23 Providing, Lowering, Laying In Trenches, Aligning, Fixing In Position And Jointing Ductile Iron ( Di ) Isi Marked K-9 Grade S&S Pipes As Per 15:8329-2000 ( Amended Upto Date ) , With Internal Cement Mortar Lining Suitable For Potable Water With Rubber Ring ( Epdm ) Joints As Per Is: 5382- 1985 Including All Taxes ( Central And Local ) , Transportation And Freight Charges, Inspection Charges, Loading / I.I Unloading Charges, Including Cost Of Labour And Material, Specials ( Tee, Bend Etc. ) Satisfactory Hydraulic Testing, Disinfection Etc. Complete As Per Technical Specifications And Direction Of Engineer-In Charge. ( Excluding Earth Work ) Note : Providing And Fixing Of All Requisite Specials As Per Drawing, Design And Layout Are Inclusive In Rm Measurement Of The Item And Shall Not Be Paid Separately. 24 150 Mm Dia 25 Providing, Lowering, Laying And Jointing In Trenches, Standard Lengths Hdpe Pe- 80 Pn-6 Isi Marked Pipes As Per Is-4984:1995 ( Ammended Upto Date ) With Neccessary Jointing Material Like Mechanical Connectors, I.E. Thread / Insert Joint / Quick Release Coupler Joint / Compression Fitting Joint Or Flanged Joint And Specials Jointing Pipe By Butt Fusion / Electro Fusion Welding Method, Including All Taxes, Transportation And Freight Charges, Inspection Charges, Loading / Unloading Charges, Stacking Of Pipes, Including Cost Of Labour And Material, Specials ( Tee, Bends Etc. ) , Satisfactory Hydraulic Testing, Disinfection Etc. Complete As Per Technical Specifications And Direction Of Engineer-In-Charge Of Following Class And Diameter. ( Excluding Earthwork ) 26 75 Mm Dia 27 90 Mm Dia 28 110 Mm Dia 29 125 Mm Dia 30 140 Mm Dia 31 160 Mm Dia 32 180 Mm Dia 33 200 Mm Dia 34 225 Mm Dia 35 Providing, Lowering, Aligning, Fixing In Position And Jointing In Pipe Line, Combination Air Release Valve Kinetic Type With Single Chamber Housed Double Orifice And Have 3 Functions, Large Air Exhaust, Small Air Venting And Large Air Intake During Vacuum Of Pipeline Of Approved Makes Of Following Pressure Rating And Dia And As Per Following Specifications:Governing Standard - Awwa C512 , Body And Bonnet Of Ductile Cast Iron Of Grade Ggg40 / Ggg50 As Per Din 1693 Or Gr Sg-400 / 12 As Per Is 1865, Float & Internal Trim: Aisi 304 Stainless Steel, Seat Ring & Gasket - Epdm / Nbrdrilled As Per Is:1538. Electrostatic Epoxy Powder ( Ep-P ) / Fusion Bonded Epoxy ( Non-Toxic & Suitable For Drinking Water ) Coated With Minimum Thickness Of 250 Micron Applied On Body & Coverinside And Outside Fasteners - Cs / Galvanised Steel , Outlet Of Big Orifice Will Have A Screen To Prevent Tamper Of Float, Big Orifice Size Should Be Equal Or Larger Than The Inlet Flange Bore, For Fully Comply With Awwa C512. ) , Valve Including All Material, Labour, Testing And Commissioning As Per Technical Specifications And As Per Direction Of Engineer In Charge.Note: Rates Are Exclusive Of Connecting Tee, Pipe Piece And Earth Work. 36 50 Mm Dia 37 Construction Of Air Valve Pillar For Fixing Of Air Valves 38 Providing, Lowering, Aligning, Fixing In Position In Pipe Line At Work Site, Di D / F Resilient Seated ( Soft Seated ) Sluice Valves ( Gate Valves ) , Vacuum Tight ( Bubble Tight ) , Straight And Pocket Less Body Passage Of Approved Make Of Following Class & Dia Complete Confirming To Bs-En-1171 / Awwa C-509 And Of Following Specifications: Body & Bonnet Of Ductile Cast Iron Of Grade Ggg40 / Ggg50 As Per Din 1693 Or Gr Sg-400 / 12 As Per Is 1865 Or Equivalent Grade As Per Is :3896-Part2-1985 And Subsequent Revisions, Wedge Of Same Material As Body & Shall Vulcanisedrubber Lined With Epdm ( Food Grade Quality ) And Seals Of Nbr Face To Face Dimensions As Per Bs 5163-89 / Is 14846 / 2000 ( Amended Up To Date ) / Din 3202 F4, Stem / Spindle Of Ss ( Aisi 316 Or Equivalent ) Electrostatic Epoxy Powder ( Ep-P ) / Fusion Bond Epoxy ( Non-Toxic- Suitable For Drinking Water ) Coated With Minimum Thickness Of 250 Microns Inside And Outside, Drilled As Per Is 1538. Nut-Bolt Confirming To Is:1363 And Is: 1367 ( Galvanised Steel ) Insersion Rubber Of Black Epdm 6Mm Thick. Suitablesupport Structure As Per Directions Of Eic, Sluice Valves Including All Jointing & Jointing Material, Labour, Testing And Commissioning Along With Pipe Line As Per Technical Specifications And As Per Direction Of Engineer-In-Charge. Note: Rates Are Exclusive Of Tail Piece / Dismantling Joints And Earth Work.Manually Operated Resilient Seated Sluice Valves Of Class Pn 1.0 / 1.6 39 100 Mm Dia 40 150 Mm Dia 41 200 Mm Dia 42 Providing, Lowering, Aligning, Fixingin Positionin Pipeline, Cid / Fsluicevalvesof Approved Make Of Following Pressure Rating & Dia Complete, Confirming To Is:14846 ( Amended Up To Date ) And Of Following Specifications: Body, Bonnet, Wedge, Gland, Thrust Plate, Cap & Hand Wheel Of Grey Cast Iron Of Is:210 / Fg200stem - Ss 304 , Body Seat Ring, Wedge Facing Ring & Bushes - Ltb2 / Ss, Face To Face Dimensions As Per Is 14846 / 2000 ( Amended Up To Date ) , All Exposed Machined Ferrous Surfaces Shall Be Painted With One Coat Of Aluminium Red Oxide Primer Conforming To Is:5660 And Two Coats Of Black Japan Paint Conforming Totype B Of Is 341Or Paint Conforming To Is9862 Or Is2932 ( Non-Toxic- Suitable For Drinking Water ) Applied Inside And Outside, Flanges Drilled As Per Is 1538.Nut-Bolt Confirming To Is:1363 And Is: 1367 / Cs / Galvanised Steel.Insersion Rubber Of Black Epdm 6Mm Thick . Suitablesupport Structure As Per Directions Of Eic. Sluice Valves Including All Jointing & Jointing Material, Labour, Testing And Commissioning Along With Pipe Line As Per Technical Specifications And As Per Direction Of Engineer-In-Charge. Manually Operated Ci Sluice Valves Of Class Pn 1.0 Note: Rates Are Exclusive Of Tail Piece / Dismantling Joints And Earth Work. 43 80 Mm Dia 44 100 Mm Dia 45 125 Mm Dia 46 150 Mm Dia 47 200 Mm Dia 48 250 Mm Dia 49 300 Mm Dia 50 Cosntruction Of Valve Chamber For Sluice Valves, Flow Control Valve And Butterfly Valve As Per Approved Drawing And Specifications To The Satisfaction Of Engineer-In-Charge 51 Type - A ( 80 Mm To 100 Mm Dia ) 52 Type - B ( 125 Mm To 200 Mm Dia ) 53 Type - C ( 250 Mm To 350 Mm Dia ) 54 Construction Of Village Transfer Chamber As Per Approved Design, Drawing & Specification Given For Material Of Construction And Completion Of All Works Of Installation Of Sluice Valves, D.Joints, C.I. Pipes, Specials ( Excluding Supply ) Etc. Complete In All Respect To Achieve The Work As Given In The Scope Of Work. 55 Providing, Lowering, Laying, Aligning, Fixing In Position And Jointing Ci Dismantling Joint ( Suitable For Sluice Valves Etc. ) As Per Is Specifications Complete Of The Following Sizes Including All Jointing Material, Cost Of All Labour, Testing And Commissioning As Per Technical Specifications And As Per Direction Of Engineer. 56 100 Mm Dia 57 150 Mm Dia 58 200 Mm Dia 59 250 Mm Dia 60 300 Mm Dia 61 Construction And Commissioning Of Rcc Intze Type Over Head Service Reservoir Of Following Capacity And Staging As Per The Scope Of Work And Technical Specifications, Consisting Of The Following Main Activities: - 62 A ) Topographic Survey, Preparation Of Site Contour Plan, Conducting Sbc Testand Its Approval From Departmentbefore Construction. Submission And Approval Of Concrete Mix Design And Water Quality Test Report For Water To Be Used In Construction. B ) Excavation In All Types Of Soil, Pcc Below Foundation, All Rcc Work, Plinth Protection All Around The Structure Including All Material, Labour, Shuttering, Scaffolding Etc.C ) Ohsr Shall Be Provided With Adequate Plinth Protection All Around The Structure In A Width Starting From Edge Of Structure At Gl And Extending At Least Up To 1.0M Beyond The Edge Of Outer Most Projection Of Ohsr.The Plinth Protection Shall Consist Of 150Mm Thick Pcc In M-15 Grade Concrete Laid Over 150Mm Thick Layer Of Compacted Soil.D ) Providing And Applying Two Coats Of Food Grade Epoxy Paint On The Inside Surface On The Top Dome, Edge Beam And 600 Mm Height Of The Vertical Wall.E ) Conducting Successfully Hydro Test And Water Tightness Test As Per I.S. Code.F ) Providing And Applying Three Coats Of Anti-Carbonation Paint On The Top Surface Of The Top Dome.G ) Providing And Applying Three Coats Of Cement-Based Paint On The External Surface Of The Container, Balcony, Cone Wall, Columns & Beams Etc..H ) Providing And Fixing Ss-304 Ventilator, Ss 304 Manhole Frame And Cover And Ss-304 Ladder From Top Dome / Slab To Bottom Dome / Slab Inside Container. I ) Providing And Fixing Of Ms Section Ladder From The Last Landing To Balcony Having Railing All Around It And Ms Ladder With Safety Cage From Balcony To Top Dome / Slab.J ) Providing And Fixing Water Level Indicator ( Float Type ) . 63 K ) Providing And Fixing Of Hand Railing All Around The Balcony, Top Dome And Staircase Consisting Of 25Mm Diameter Class-B Gi Pipe In Two Rows And 1000 Mm High, 50X50x6mm Angle Iron Vertical Post At A Maximum Spacing Of 1500Mm Centres.L ) All Ms Parts To Be Painted With Two Coats Of The Enamel Paint Over The Primer Coat Of Red Oxide.M ) Providing And Fixing Of 150Mm Wide Pvc Water Bar For The Construction Joints In The Container ( Vertical Wall & Cone Wall ) .N ) Providing One Aluminium Portable Ladder Of Appropriate Length To Access First Landing ( 3.5 To 4.5M Above Gl ) From Ground.O ) Lighting Arrestor Consisting Of Providing And Fixing Of 2 Nos.Of Chemical Earthing And Connecting It To The Conical Cover Of Ss Ventilator With Two Separate Gi Strips Of 50Mmx3mm.P ) Ci / Di Puddle Collar Shall Be Fixed In The Bottom Dome / Slab For Connecting Inlet, Outlet, Overflow And Washout Pipe Of The Reservoir.Q ) Painting The Name Of The Scheme And Other Details On The Reservoir, And Any Other Work Related To Structure As Per The Directions Of Engineer-In- Charge, Technical Specification And Scope Of Work.R ) Inlet, Outlet, Overflow, Washout Pipes And Valves Are Not Included In This Work, Provision For The Same Shall Be Taken Separately. 64 Rates For Rcc Ohsr, Sbc 10 T / Sqm, Seismic Zone-Ii & Staging 18 M 65 100 Kl 66 150 Kl 67 Rates For Rcc Ohsr, Sbc 10 T / Sqm, Seismic Zone-Ii & Staging 20 M 68 100 Kl Each ( 100 X 2 Nos. ) 69 200 Kl Each ( 200 Kl X 3 Nos. ) 70 Providing And Fixing Double Flanged Isi Marked Di Class K-9 Pipes As Per Is:8329-2000 ( Amended Up To Date ) , As Vertical Pipes For Rcc Reservoirs Including Specials Required Such As Duck Foot Bend, Bend, Tee Etc. Providing Clamps At Every 3 Mtr, Jointing Materials Such As Nuts, Bolt, Rubber Packing, Hydraulic Testing Etc. Complete In All Respect Up To And From Valve Chamber As Per Direction Of Eic, Technical Specification And Scope Of Work. 71 100 Mm Dia 72 150 Mm Dia 73 200 Mm Dia 74 Construction Of Boundary Wall Of Brick / Stone Masonary As Per Enclosed Ga Drawing, Scope Of Work And Technical Specifications Complete Work In All Respect. Brief Details Of Boundary Wall Parameter Is As Below:1. Depth Of Foundation- 900 Mm.2. Pcc In M-10, Width -900 Mm And Thickness 100 Mm, 3. Section Of Foundation Above Pcc W-600 Mm, D-450Mm, W- 450Mm, D-450 Mm.4. Superstructure Work: Stone Masonary W-300, Height-1650 Mm, / Brick Work W-230 Mm, Height- 1650 Mm.5. Cement Mortar Pointing On Stone Masonary And Cement Mortar Plaster 20 Mm Thick On Brick Masonary In Cm 1:6.6. Expansion Joint Shall Be On Every 30 Mtr.7. On Top Of Wall There Shall Be Cc Coping 75 Mm Thick ( 1:2:4 ) Shall Be Provided.8. Pillar For Main Gate 350X350 Mm In Size Is Part Of Boundary Wall.9. Cement Paint Of Approved Colour In 3 Coat Shall Be Done. 75 Providing And Fixing Steel, Gate, Grating And Grills Made Of Angles, Tees, Square Bars, Flats Or Black Pipe With Hold Fast And Fitting Complete As Per Design And Drawing Including Cutting Welding And Fabrication With Priming Coat Of Red Oxide And Two Coat Of Enamal Paints. 76 Dismantling Of Cement Concrete Pavement For Pipe Lineand Chambers By Mechanical Means Using Pneumatic Tools, Cutting The Peripheral Edge By Cc Cutter, Breaking To Pieces Not Exceeding 0.02 Cum In Volume And Stock Piling At Designated Locations And Disposal Of Dismantled Materials Up To A Lead Of 1000 Meters. Measurement For Dismantled Trench To Be Madeas Per Standard Trench Width Specified In Tender Document And No Extra Payment Shallbe Made For Trench Width More Than Specified, Re-Handling Of Material / Earth To Complete The Tasks As Per Technical Specification And Scope Of Work. 77 Providing And Laying In Position Cement Concrete M10 Grade Nominal Mix 1:4:8 ( 1 Cement : 4Coarse Sand : 8 Graded Stone Aggregate 40 Mm Nominal Size ) In Base Course Complete Including All Material, Labour, Machinery, Lighting, Guarding For Road Restoration Work In Trenches Of Pipe Line And Chamber Work. Measurement For Cc Work To Be Madeas Per Standard Trench Width Specified In Tender Document And No Extra Payment Shall Be Made Be Made For Trench Width More Than Specified, Complete Work As Per Technical Specification And Scope Of Work. 78 Providing And Laying In Position Cement Concrete In Specified Grade Over Prepared Base Course Complete Including Finishing, Curing, All Material, Labour, Machinery, Lighting, Guarding For Road Restoration Work In Trenches Of Pipe Line And Chamber Work. Measurement For Cc Work To Be Madeas Per Standard Trench Width Specified In Tender Document And No Extra Payment Shall Be Made Be Made For Trench Width More Than Specified, Complete Work As Per Technical Specification And Scope Of Work. M20 Grade Nominal Mix1: 1.5: 3 ( 1 Cement : 1.5 Coarse Sand : 3 Graded Stone Aggregate 20Mm Nominal Size ) . 79 Dismantling Of Flexible Pavement For Pipe Lineand Chambers By Mechanical Means Using Pneumatic Tools, Breaking To Pieces Not Exceeding 0.02 Cum In Volume And Stock Piling At Designated Locations And Disposal Of Dismantled Materials Up To A Lead Of 1000 Meters. Measurement For Dismantled Trench To Be Madeas Per Standard Trench Width Specified In Tender Document And No Extra Payment Shall Be Madefor Trench Width More Than Specified, Re-Handling Of Material / Earth To Complete The Tasks Per Technical Specification And Scope Of Work. 80 Bituminous Courses 81 Granular Courses 82 Provision For Restroration Of Bitumen Road After Laying & Jointing Pipe Line As Per Direction Of Engineer In Charge 83 Provision Forrestoration Of Wbm Road Cutting As Per Specifications. 84 Total Length Of Canal Corssing During Laying Of Pipe At Various Locations 85 Providing Service Connection As Per Technical Specification And Standard Drawing As Per Relevant Is Code ( Ammended Up To Date ) From All Kind Of Water Mains Up To Consumer Meter / Premises ( Complete Job ) . This Job Includes Digging Out Suitable Size Of Pits And Trench For Laying Service Line In All Kinds Of Soil Including Demolishing Of Cement Concrete, Wbm, Black Top Etc. Of All Thickness; Cutting Of Cc Road / Jhiri By Using A Concrete Cutter Machine; Depositing And Refilling Of Pit & Jhiri Watering And Ramming / Compacting In Layers And Disposal Of Surplus Excavated Soilas Directed With In A Lead Of 50 Meter; Providing And Fixing Of All Fitting Duty Approved In Accordance With Iso / Dtr 9080 As Per Specification For Portable Water Including Approved Make Of Ms / Pvc Clamp With Saddle Piece, Gunmetal Ferrule 4.0 Mm ( Isi Make ) , Valve ( Is: 778 ) And Specials With Mdpe Pipe Pe 80 Pn 12.5 As Per Iso 4424 Below Ground Level And P&F Gi Pipe 15 Mm Dia Class B ( Isi Mark ) Above Ground Level In The Premises For Fixing Tap ( Max. Length2.0 Mtr. ) , P&F A 15 Mm Bib Cork With Foam Flow Chrome Plated With Complete Brass Body Including Brass Handle Having Good Quality With Wt 300 To 325 Gm, Including Accessories With Flushing , Cleaning, Disinfecting And Testing Of Pipeline Complete Required For Making Of Service Connection Complete In All Respect Including Labour Charges. In Addition To The Ferrule, An Orrifice Of 4.0Mm Dia Should Also Be Provided In The Service Line At The Entry Pointy Of ConsumerS Property In Such A Way That It Should Be Accessible For Inspection To Vwsc, Phed And Any Other Authority Which Woyld Like To Inspect As And When Required. The Service Line Should Be Laid Atleast 45 Cm Below Ground Level, Except In Case Of Concrete / Bituminous Raods Where Minimum Depth Shall Be 20Cm. For Details Specifications Of Mdpe Pipes Please Refer Technical Specifications Of Bid Document. General Specifications Of Mdpe Pipes Shall Be As Under: The Raw Material Shall Be Virging Pe 80 Blue Compound And Comply With The Requirement Of Iso / Directive Of Testing Material : 9080 With Minimum Required Strength Of 8 Kg / Sq.Cm. ; The Raw Material Shall Be Food Grade Quality ; Ressure Rating Shall Be 12.5 Bar ; The Pipes Shall Bear Iso Marking 86 Removing& Re-Fixing Of Precast Concrete Interlocking Blocks By Manual, Stacking Of Serviciable & Non Serviceable Material Separately. Disposal Of Dismantled Material Lead Up To 50 Mtr. The C.C. Interlocking Paving Blocks Be Laid On Average 25 Mm Thick Bed Of Coarse Sand And The Joints To Be Filled With Fine Sand. Laying Procedure On Compacted Sub Base As Defined. Complete Job Is To Be Executed As Per The Directions Of Engineer In Charge. The Rates To Be Inclusive Of Fixing Of Minimum 70 Percent Reusable Precast Concrete Interlockingblock And Cost Of Required New Precast Concrete Interlocking Block Against Damaged, Including Alllead And Lift As Per Technical Specifications. ( Interlocking Blockmanufactured By Fully Computerized Automatic Stationery Hydraulic Vibro Pressed Machine & Full Computerized Automatic Batching Plant Of Class A-1 As Per Bs:6717-2001. Tensile Splitting Strength And Breaking Load As Per Bs: 6717-2001Colour: Grey Cement Natural Colour. Variation In Dimension : Less Than 1.6 Mm Variation In Thickness: Less Than 3.2 Mm ) 80 Mm Thick 87 Add Extra Over Item No 1.21 & 1.22 For Providing20 Mm Pe80 Pn 16 As Per Iso 4427 Mdpe Pipe Including Excavation, Providing, Laying & Jointing Of Service Line Above 5.00 Mtr. 88 Supply Laying And Pushing Of Ms Casing Pipe Of Specified Thickness Approved By Concerned Department Authority By Trenchless Method Adopting Any Suitable Technology Below Ground At Required Depth Under Running Traffic Condition As Per Highway / Railway Standard Including Carrying Out Survey Work At The Job Site For Determining Underground Cable Trenches Like Telephone, Cable, Water & Sanitary Lines And Resistivity Test For Finding The Soil Strata Using Necessary Equipments For Completion Of Works, Mobilizing Of Machineries And Specialized Crew At The Job Site Complete In All Respect, Including Excavation Of Driven Pit And Exit Pit ( Up To 3 Meter Depth ) With Proper Protection At These Sites With Shoring Sheets And Ismb. Providing Ms Cutting Edges For Front Shield And Constructing Thrust Bed At Designated Level. Necessary Dewatering And Providing Concrete Foundation At The Base Of The Driven Pit, Pvc / Rubber Saddle As Per The Requirement Of Highway / Railway Authority, Crane For Handing Of Pipe And Any Other Machinery, Tools, And Tackles Required, Construction Of Temporary Works As Per Design, Drawing And Method As Per Approved Byauthority Specification And The Direction Of The Engineer.Apply Corrosion, Resistant, Protection On Inside And Outside Of Casing Pipeas Per Technical Specification. 89 300 Mm Dia 8 Mm Thick Casing Pipe With Protective Coating. 90 Part B : Pump House & Cwr 91 Fabrication, Supply Of Flanged / Plain Ended Ms Pipe Made From Ms Sheet Strips Of Relevant Is Specification Of Approved Thickness By Welding, Lowering, Laying, Aligning, Fixing In Position At All Level / Depths In Trenches Complete Excluding Flanged Jointing Wherever ( Required ) Including All Material, Labour, Testing And Commissioning Along With Pipe Line As Per Technical Specifications And As Per Direction Of Engineer. 92 Ms Pipe Upto 600 Mm Dia ( With Minimum 5Mm Thickness Sheet 93 Ms Pipe Above 600Mm Dia ( With Minimum 6.3Mm Thickness Sheet ) 94 Providing, Lowering, Aligning, Fixing In Position In Pipe Line At Work Site, Di D / F Resilient Seated ( Soft Seated ) Sluice Valves ( Gate Valves ) , Vacuum Tight ( Bubble Tight ) , Straight And Pocket Less Body Passage Of Approved Make Of Following Class & Dia Complete Confirming To Bs-En-1171 / Awwa C-509 And Of Following Specifications: Body & Bonnet Of Ductile Cast Iron Of Grade Ggg40 / Ggg50 As Per Din 1693 Or Gr Sg-400 / 12 As Per Is 1865 Or Equivalent Grade As Per Is :3896-Part2-1985 And Subsequent Revisions, Wedge Of Same Material As Body & Shall Vulcanisedrubber Lined With Epdm ( Food Grade Quality ) And Seals Of Nbr Face To Face Dimensions As Per Bs 5163-89 / Is 14846 / 2000 ( Amended Up To Date ) / Din 3202 F4, Stem / Spindle Of Ss ( Aisi 316 Or Equivalent ) Electrostatic Epoxy Powder ( Ep-P ) / Fusion Bond Epoxy ( Non-Toxic- Suitable For Drinking Water ) Coated With Minimum Thickness Of 250 Microns Inside And Outside, Drilled As Per Is 1538. Nut-Bolt Confirming To Is:1363 And Is: 1367 ( Galvanised Steel ) Insersion Rubber Of Black Epdm 6Mm Thick. Suitablesupport Structure As Per Directions Of Eic, Sluice Valves Including All Jointing & Jointing Material, Labour, Testing And Commissioning Along With Pipe Line As Per Technical Specifications And As Per Direction Of Engineer-In-Charge. Note: Rates Are Exclusive Of Tail Piece / Dismantling Joints And Earth Work.Manually Operated Resilient Seated Sluice Valves Of Class Pn 1.0 / 1.6 95 100 Mm Dia 96 125 Mm Dia 97 150Mm Dia 98 200 Mm Dia 99 250 Mm Dia 100 300 Mm Dia 101 450 Mm Dia 102 500 Mm Dia 103 600 Mm Dia 104 700 Mm Dia 105 900 Mm Dia 106 Providing, Lowering, Laying, Aligning, Fixing In Position And Jointing Ci Dismantling Joint ( Suitable For Sluice Valves Etc. ) As Per Is Specifications Complete Of The Following Sizes Including All Jointing Material, Cost Of All Labour, Testing And Commissioning As Per Technical Specifications And As Per Direction Of Engineer. 107 100 Mm Dia 108 125 Mm Dia 109 150 Mm Dia 110 200 Mm Dia 111 250 Mm Dia 112 300 Mm Dia 113 450 Mm Dia 114 500 Mm Dia 115 600 Mm Dia 116 900 Mm Dia 117 1000 Mm Dia 118 Cosntruction Of Valve Chamber For Sluice And Butterfly Valves As Per Approved Drawing And Specifications To The Satisfaction Of Engineer-In-Charge 119 Valve Chamber ( 80 Mm To 100 Mm Dia ) 120 Valve Chamber ( 500 To 600 Mm ) 121 Providing, Lowering, Aligning, Fixing In Position In Pipe Line, Di D / F Resilient Seated ( Soft Seated ) Short Body Pattern Type Double Eccentric Butterfly Valves Of Approved Make Of Following Class & Dia Complete Confirming To Bs En 593 / Bs 5155 / Is 13095 / 1991 Amendedup To Date And Of Following Specifications: Body, Disc And End Cover Of Ductile Cast Iron Of Grade Ggg40 / Ggg50 As Per Din 1693 Or Gr Sg-400 / 12 As Per Is 1865 Or Equivalent Grade As Per Is :3896-Part2-1985 And Subsequent Revisions, Face To Face Dimensions As Per Din 3202 F4 / Is 13095Drilled As Per Is:1538. Electrostatic Epoxy Powder ( Ep-P ) / Fusion Bonded Epoxy ( Non-Toxic & Suitable For Drinking Water ) Coated With Minimum Thickness Of 250 Micron Applied On Both Body And Disc Inside And Outside. Disc Seal Ring Of Epdm / Neoprene ( Food Grade Quality ) And Disc Seal Retaining Ring Of Ss / Cs. Shaft Of Ss- Aisi- 304 / 316 & Shaft Bearings-Bronze / Ptet Or Teflon With Epdm / Nbr O Ring Seal, Nut-Bolt Confirming To Is:1363 And Is: 1367 ( Galvanised Steel ) Insersion Rubber Of Black Epdm 6Mm Thick. Suitablesupport Structure As Per Directions Of Eic Including Jointing & Jointing Material, Labour, Testing And Commissioning Along With Pipeline As Per Technical Specification & As Per Direction Of Engineer-In-Charge.Class Pn 1.6, Motorised Operatednote: Rates Are Exclusive Of Tail Piece / Dismantling Joints And Earth Work. 122 100 Mm Dia 123 150 Mm Dia 124 250 Mm Dia 125 450 Mm Dia 126 500 Mm Dia 127 600 Mm Dia 128 Providing, Lowering, Laying, Aligning, Fixing In Position And Jointing In Pipe Line, Di Dual Plate Check Valves Of Pn 1.6 Rating Of Following Dia ( Including Jointing And Jointing Material ) , Including All Material, Labour, Testing And Commissioning As Per Technical Specifications And As Per Direction Of Engineer. 129 100 Mm Dia 130 125 Mm Dia 131 150 Mm Dia 132 250 Mm Dia 133 450 Mm Dia 134 500 Mm Dia 135 Providing, Lowering, Laying, Aligning, Fixing In Position And Jointing In Pipe Line, Di Dual Plate Check Valves Of Pn 1.0 Rating Of Following Dia ( Including Jointing And Jointing Material ) , Including All Material, Labour, Testing And Commissioning As Per Technical Specificationsand As Per Direction Of Engineer. 136 600 Mm Dia 137 Providing And Fixingat Site With Necessary Packing, Horizontal Centrifugal Split Casting Pumps With 4 Poleinduction Motor As Per Is 12615: 2011 Or Amended Up To Date , Ci Casing And Casing Ring, Ss 316 Impeller, Ss 410 Shaft And Shaft Sleeve, Coupling Guard, Common Base Plate, Foundation Bolts, Cement Concrete Foundation Etc. Complete With All Respect As Per The Specification And Scope Of Work And Direction Of Engineer In Charge Of Following Range Of Duty Conditions.Note: Duty Condition Of Required Pump Shall Also Be Mentioned In Boq 138 295.08 Lps, 59 M Head 139 295.08 Lps, 80 M Head 140 274.12 Lps, 61 M Head 141 Providing And Fixingat Site With Necessary Packing, Horizontal Centrifugal Split Casting Pumps With 4 Poleinduction Motor As Per Is 12615: 2011 Or Amended Up To Date , Ci Casing And Casing Ring, Ss 316 Impeller, Ss 410 Shaft And Shaft Sleeve, Coupling Guard, Common Base Plate, Foundation Bolts, Cement Concrete Foundation Etc. Complete With All Respect As Per The Specification And Scope Of Work And Direction Of Engineer In Charge Of Following Range Of Duty Conditions.Note: Duty Condition Of Required Pump Shall Also Be Mentioned In Boq. 142 25.79 Lps, 70 M Head 143 26.83 Lps, 75 M Head 144 15.14 Lps, 79 M Head 145 Providing, Installation, Testing And Commissioning Of Centrifugal Monoblock Pump Set Conforming To Is 9079 Operating At Sync. Speed 2900 Rpm With Requisite Moc Impeller, Priming Funnel, Cock, Suitable Flanges At Suction And Delivery Side. Pump Shall Have Common Shaft For Pump And Motor. Motor Shall Be Suitable For Working On 415 V ± 10%, 3 Ph, 50 Hz A.C. Supply. Motor Shall Be Tefc Type And Pump Set Shall Be Suitable For Working At Various Discharge And Head Requirements As Per Scope Of Work. Pump Shall Be Erected Onc.C. Foundation / Cross Channels / Rsj Frame Block With Suitable Foundation Bolts Grouted In C.C. Foundation Block Etc. Complete In All Respect As Perspecification, Scope Of Work And Direction Of Engineer In Charge Of Following Power Rating, Suitable For Prescribed Duty Conditions Mentioned In Td. 146 19.31 Lps, 41M Head 147 20.62 Lps, 54 M Head 148 9.93 Lps, 78 M Head 149 26.15 Lps, 44 M Head 150 18.46 Lps, 62 M Head 151 9.39 Lps, 73 M Head 152 Supplying, Erecting, Testing & Commissioning Of Electrically Operated Travelling Crane ( Eot ) .Main Girder & End Carriage Fabricated From Rollled Steel Section, Gear Box For All Motion, Electro Magnetic Friction Disc Type Brakes, All Safety Limit Switches, Lt Wheels En 9, Double Flanged 4No, With Sq. Cage Motor Of Adequate Rating ( Kw ) , Duly Painted Mechanical Cleaning And One Coat Of Primer And Two Coat Of Synthetic Paint And As Per The Direction Of The Engineer. 153 Span 7 M 6 Mtr. Lift 154 Providing, Lowering, Aligning, Fixing In Position In Pipe Line, Ci D / F Sluice Valves Of Approved Make Of Following Pressure Rating & Dia Complete, Confirming To Is:14846 ( Amended Up To Date ) And Of Following Specifications: Body, Bonnet, Wedge, Gland, Thrust Plate, Cap & Hand Wheel Of Grey Cast Iron Of Is:210 / Fg200 Stem - Ss 304 , Body Seat Ring, Wedge Facing Ring & Bushes - Ltb2 / Ss , Face To Face Dimensions As Per Is 14846 / 2000 ( Amended Up To Date ) , All Exposed Machined Ferrous Surfaces Shall Be Painted With One Coat Of Aluminium Red Oxide Primer Conforming To Is:5660 And Two Coats Of Black Japan Paint Conforming Totype B Of Is 341Or Paint Conforming To Is9862 Or Is2932 ( Non-Toxicsuitable For Drinking Water ) Applied Inside And Outside, Flanges Drilled As Per Is 1538.Nut-Bolt Confirming To Is:1363 And Is: 1367 / Cs / Galvanised Steel.Insersion Rubber Of Black Epdm 6Mm Thick . Suitable Support Structure As Per Directions Of Eic. Sluice Valves Including All Jointing & Jointing Material, Labour, Testing And Commissioning Along With Pipe Line As Per Technical Specifications And As Per Direction Of Engineer-Incharge.Note: Rates Are Exclusive Of Tail Piece / Dismantling Joints And Earth Work.Manually Operated Ci Sluice Valve Of Class Pn-1.0 155 100 Mm Dia 156 600 Mm Dia 157 Providing And Fixing Double Flanged Isi Marked Di Class K-9 Pipes As Per Is:8329-2000 ( Amended Up To Date ) , As Vertical Pipes For Rcc Reservoirs Including Specials Required Such As Duck Foot Bend, Bend, Tee Etc. Providing Clamps At Every 3 Mtr, Jointing Materials Such As Nuts, Bolt, Rubber Packing, Hydraulic Testing Etc. Complete In All Respect Up To And From Valve Chamber As Per Direction Of Eic, Technical Specification And Scope Of Work. 158 100 Mm Dia 159 600 Mm Dia 160 700 Mm Dia 161 Design & Construction Of Clear Water Reservoirs Of Required Capacity At Following Places, Including Its Piping, Fittings, Etc Complete In All Respect As Per The Scope Of Work & Specifications Given In The Tender Document At The Following Places & Sizes . 162 Tps / Cps Bhaleri 163 Design, Manufacturing And Supply Of Batch Type Electro Chlorinator Of Capacity As Per Requirement Of Site 164 Part : C Repair Works 165 Repair Of Valves From Karamsana To Bhaleri 166 Providing, Lowering, Aligning, Fixing In Position And Jointing In Pipe Line, Di Body Flanged End Tamper Proofkinetic Air Valve Of Approved Makes Of Following Pressure Rating And Dia And As Per Following Specifications: Governing Standard - Awwa C512 / Is:14845:2000 ( Amended Up To Date ) Body, High Pressure Cover , Low Pressure Cover, Cowl Andjoint Support Ring - Ductile Cast Iron Of Grade Ggg40 / Ggg50 As Per Din 1693 Or Gr Sg-400 / 12 As Per Is 1865, Float- Lp Ball & Hp Ball : Aisi 304 Stainless Steel, Seat Ring & Gasket - Epdm / Nbr , Hp Orifice & Hp Orifice Plug : Bronze / Ss , Bush: Bronze , Flanges As Per Is / Bs, Drilled As Per Is:1538. Electrostatic Epoxy Powder ( Ep-P ) / Fusion Bonded Epoxy ( Non-Toxic & Suitable For Drinking Water ) Coated With Minimum Thickness Of 250 Micron Applied On Body & Coverinside And Outside .Fasteners - Cs / Galvanised Steel, Outlet Of Big Orifice Will Have A Screen To Prevent Tamper Of Float, With Di Metal Seated D / F Non Rising Stem. Sluice Valves As Per ( Is: 14846 Amendedupto Date ) Pn 1.6 Ratings. Valves Including All Material, Labour, Testing And Commissioning As Per Technical Specifications And As Per Direction Of Engineer In Charge. Note: Rates Are Exclusive Of Connecting Tee, Pipe Piece And Earth Work. ( Class Pn 1.6 ) 167 150 Mm Dia 168 200 Mm Dia 169 Providing, Lowering, Aligning, Fixing In Position In Pipe Line At Work Site, Di D / F Resilient Seated ( Soft Seated ) Sluice Valves ( Gate Valves ) , Vacuum Tight ( Bubble Tight ) , Straight And Pocket Less Body Passage Of Approved Make Of Following Class & Dia Complete Confirming To Bs-En-1171 / Awwa C-509 And Of Following Specifications: Body & Bonnet Of Ductile Cast Iron Of Grade Ggg40 / Ggg50 As Per Din 1693 Or Gr Sg-400 / 12 As Per Is 1865 Or Equivalent Grade As Per Is :3896-Part2-1985 And Subsequent Revisions, Wedge Of Same Material As Body & Shall Vulcanisedrubber Lined With Epdm ( Food Grade Quality ) And Seals Of Nbr Face To Face Dimensions As Per Bs 5163-89 / Is 14846 / 2000 ( Amended Up To Date ) / Din 3202 F4, Stem / Spindle Of Ss ( Aisi 316 Or Equivalent ) Electrostatic Epoxy Powder ( Ep-P ) / Fusion Bond Epoxy ( Non-Toxic- Suitable For Drinking Water ) Coated With Minimum Thickness Of 250 Microns Inside And Outside, Drilled As Per Is 1538. Nut-Bolt Confirming To Is:1363 And Is: 1367 ( Galvanised Steel ) Insersion Rubber Of Black Epdm 6Mm Thick. Suitablesupport Structure As Per Directions Of Eic, Sluice Valves Including All Jointing & Jointing Material, Labour, Testing And Commissioning Along With Pipe Line As Per Technical Specifications And As Per Direction Of Engineer-In-Charge. Note: Rates Are Exclusive Of Tail Piece / Dismantling Joints And Earth Work. 170 Manually Operated Resilient Seated Sluice Valves Of Class Pn 1.0 / 1.6Sectional Valves 171 150 Mm Dia 172 200 Mm Dia 173 900 Mm Dia With Gear 174 Providing, Lowering, Aligning, Fixing In Position And Jointing Ms Dismantling Joint Fabricated Steel ( Suitable For Sluice Valves Etc. ) As Per Is Specificationscompleteofthefollowingsizesincludingall Jointing Material, Costofalllabour, Testingandcommissioningand As Per Technical Specifications And Direction Of Engineer In-Charge. Class Pn 1.0 / 1.6 175 900 Mm Dia 176 Construction Of Valve Chamber As Per Approved Drawing And Specification Of Engineer In Charge 177 Type G Size Up To 800Mm To 900 Mm 178 Major Repair Of Pmc Office Building, Residential Buildings At Pmc Campus, All Work Civil, Electric, Water Supply, Road, Drainage Cleaning, Horticulture, Etc. Complete 179 Earth Work In Excavation By Mechanical Means ( Hydraulic Excavator ) / Manual Means In Foundation Trenches Or Drains ( Not Exceeding 1.5 M In Width Or 10 Sqm On Plan ) Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Taking Out The Excavated Soil And Depositing And Refilling Of Jhiri With Watering & Ramming And Disposal Of Surplus Excavated Soil As Directed With In A Lead Of 50 Meter.All Kinds Of Soils 180 Random Rubble Stone Masonary For Foundation And Plinth In Cement Sand Mortar Above 30 Cm. Thick Wall In : 181 Cement Mortar 1:6 ( 1-Cement:6-Sand ) . 182 Brick Work With F.P.S. Bricks Of Class Designation 75 Infoundation And Plinth In: 183 Cement Mortar 1:6 ( 1-Cement:6-Coarse Sand ) . 184 Repair To Brick Masonary In Cement Sand Mortar With Taking Out Of Deceayed From Wall And Replaceing With New Briks.Cement Sand Mortar 1:6. With New Brick. 185 Repairs To Plaster Of Thickness 12Mm To 20Mm In Patches Of Area 2.5 Sq. Metres And Under Including Cutting The Patch In Proper Shape, Raking Out Joints And Preparing And Plastering The Surface Of The Walls Complete Including Disposal Of Rubbish To The Dumping Ground Within 50 M Lead : With Cement Mortar 1 :4 ( 1 Cement : 4 Fine Sand ) 186 Repair To Stone Masonary In Cement Sand Mortar 1:6 With Old And New Stone. 187 Cutting Jhiri Above 75Mmx75mm And Below 150X150 Mm Etc. And Making Good. 188 Scraping Old Surface And Redoing Lime Loi Or Sandla. 189 Renewing Glass Panes, With Puty And Nails Wherever Necessary: 190 5.5 Mm Thick Plain Glass Panes. 191 Renewing Glass Panes With Wooden Fillets Wherever Necessary: 192 5.5 Mm Thick Plain Glass Panes. 193 Providing And Fixing 16 Mm M.S. Fan Clamps Of Standard Shape And Size In R.C.C. Slab / Stone Slab Roofing Including Cutting Chase And Making Good And Painting Exposed Portion Of The Clamps Complete: 194 In Existing Roof. 195 Guniting Damaged R.C.C. Slab, Beams And Columns For Strengthening With Cement Sand Mortar 1:2 ( 1-Cement:2-Sand ) Including Preparing The Surface, Making V Shaped Joints, Cleaning The Reinforcement Bars With Jet Of Potable Water And Drying With Compressed Air, Including Cost Of Centering And Shuttering And Finishing To Match The Existing Surface Etc. Complete, Including Provided M.S. Welded Mesh To Gauge 25 Mm X 25 Mm Framing With Average Thickness Of 25 Mm. 196 Chopping Loose And Cracked Concrete To Required Depth, Cleaning The Exposed Surface Of Steel And Concrete With Wire Brush And Sand Blasting, Clening With A Jet Of Water / Air As Necessary And Getting It Dried With Compressed Air Including All Scaffolding: 197 Depth 50 Mm To 75 Mm. 198 Depth 75 Mm To 100 Mm. 199 Repairofdoor, Windowshuttersincludingcostofmaterialandlabourforchangeofdamaged : 200 Style / Rail Of Teak Wood 30Mm Thick / Aluminium Section 201 4Wide 202 6 Wide 203 Panel By 204 Shuttering Ply - 9Mm Thick ( Commercial ) 205 Wire Gauge 14 Mesh X 24 Gauge 206 Plain Glass Panes 4Mm Thick 207 Aldrop Of Mild Steel 208 12 Long X12mm Dia 209 8 Long X 10Mm Dia 210 Stopper Of Aluminium With 211 Single Rubber Gutka 212 Double Rubber Gutka 213 Door Springs Of Mild Steel 214 Steel Hinges 215 For Wooden Chowkhat 3 Size. 216 For Wooden Chowkhat 4 Size 217 For Stone Chowkhat , 4Size 218 Mild Steel Tower Bolt 6 Long 219 Steel Locking Bolt 220 Steel Handle 6 Size 221 Providing And Laying In Position Cement Concrete Including Curing Compaction Etc. Of Specified Grade Excluding The Cost Of Centering And Shuttering =All Up To Plinth Level 222 M15 Grade Nominal Mix 1: 2: 4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stoneaggregate 20Mm Nominal Size ) . 223 M10 Grade Nominal Mix 1: 3: 6 ( 1 Cement : 3 Coarse Sand : 6 Graded Stoneaggregate 20Mm Nominal Size ) . 224 Making Plinth Protection 50Mm Thick Of Cement Concrete 1:3:6 ( 1 Cement : 3 Coarse Sand : 6 Graded Stone Aggre -Gate 20 Mm Nominal Size ) Over 75Mm Bed Of Dry Brick Ballast 40Mm Nominal Size Well Rammed And Consolidated And Grouted With Fine Sand Including Finishing The Top Smooth. 225 Providing And Laying In Position Specified Grade Ofcement Concrete For Rcc Structural Elements Upto Floor Five Level Including Curing, Compaction, Finishing With Rendering In Cement Sand Mortar 1:3 ( 1 Cement: 3 Coarse Sand ) And Making Good The Joints And Cost Of Plastizers ( If Required ) Excluding The Cost Of Centering, Shuttering And Reinforcementfor Walls ( Any Thickness ) Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc. M20 Grade Nominal Mix / Design Mix 226 Centering & Shuttering With Plywood Or Steel Sheets Including Strutting, Propping Bracing Both Ways With Steel Propsand Removal Of Formwork For Upto Floor Five Level For : 227 Suspended Floors, Roofs, Landings, Staircases, Balconies, Girders, Cantilevers, Bands , Coping, Bed Plates, Anchor Blocks, Sills, Chhajjas Lintel, Beam Etc. 228 Providing And Fabricating Reinforcement For R.C.C. Work Including Straightening, Cutting, Bending, Placing In Position And Binding ( Including Cost Of Binding Wire ) All Complete Up To Floor Five Level. 229 Hot Rolled Deformed Bars ( Is : 1139 ) . 230 Plaster On New Surface On Walls In Cement Sand Mortar 1:6 Including Racking Of Joint Etc. Complete Fine Finished: 231 20 Mm Thick. 232 Providing And Fixing Expanded Metal Mesh Of Size 20X60 Mm And Strands 3.5 Mm Vide 1.6 Mm Thick Weighing 3.64 Kg. Per Sqm. For Encasing Ofrolledsteel Sections In Beams, Columns And Grillages Excluding Cost Of Hangers. 233 Brick Work With F.P.S. Bricks Of Class Designation 75 In Superstructure Above Plinth Level Upto Floor V Level In All Shapes And Sizes In : 234 Cement Mortar 1:6 ( 1-Cement:6-Coarse Sand ) . 235 Half Brick Masonry In Superstructure , Above Plinth Level Upto Floor Fivelevelusing F.P.S. Bricks Of Designation 75 236 Cement Mortar 1:4 ( 1-Cement:4-Coarse Sand ) . 237 Brick Work In Partition In Super Structure Upto Five Storey 7Cm. Thick ( Brick On Edges ) Using F.P.S. Bricksof Class Designation 75 In : 238 Cement Mortar 1:4 ( 1-Cement:4-Coarse Sand ) . 239 Supplying And Fixing Machine Cut And Polished Stone Shelves, Tands And Sills In Cm 1:3 With Machine Cut Edges: 240 Sand Or Other Approved Stone 25 Mm Thick. 241 Sand Or Other Approved Stone 35 Mm Thick. 242 Sand Or Other Approved Stone 50 Mm Thick. 243 Kota Stone 25 To 30 Mm Thick. 244 Providing And Fixing Granite Stone Slab Mirror Polished And Machine Edge Cut In Walls, Pillars, Steps, Shelves, Sills, Counters. Floors Etc. Laid On 12Mm ( Av. ) Thick Base Of Cement Mortar 1:3 Jointing With White Cement Mortar 1:2 ( 1 White Cement: 2 Marble Dust ) With Pigment To Match The Shade Of The Marble Slab Complete Including Grinding, Rubbing And Polishing Of: 245 Jhunjhunu / Jalore ( Red / Choclate Colour ) 246 Above 3601 Cm2 Slabs 247 Providing And Laying Vitrified Floor Tiles In Different Sizes ( Thickness To Be Specified By The Manufacturer ) With Water Absorption’S Less Than 0.08% And Conforming To Is : 15622 Of Approved Make In All Colours And Shades, Laid On 20Mm Thick Cement Mortar 1:4 ( 1 Cement: 4 Coarse Sand ) Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete. 248 Size Of Tile 60X60 Cm 249 Providing And Fixing Ist Quality Ceramic Glazed Wall Tiles Conforming To Is : 15622 ( Thickness To Be Specified By The Manufacture ) Of Approved Make In All Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Engineer In Charge In Skiriting, Risers Of Steps And Dados Over 12 Mm Thick Bed Of Cement Mortar 1:3 ( 1 Cement : 3 Coarse Sand ) And Jointing With Grey Cement Slurry @ 3.3 Kg Per Sqm Including Pointing In White Mixed With Pigment Of Matching Shade Complete. 250 Category - I : Kajariya, Jhonson, Orient, Somani Make Etc. 251 Providing & Fixing In Cement Sand Mortar 1:4 Single Paitam ( Rebated ) Stone Doors Windows And Ventilator Frames Of Approved Quarry : 252 Size 100X75mm. 253 Size 125X100mm. 254 Providing And Fixing In Cm 1:4 Double Paitam ( Rebated ) Stone Door Window And Ventilator Frames Of Approved Quarry : 255 Size 125 X 100Mm. 256 Providing And Fixing External Grade Board Solid Core Single Leaf Flush Door Shutters Isi 2202-67 Marked Using Phenol Formal, Dehydreresin In Glue Both Sides With Approved Steel Fittings Complete As Per Annexure ‘A’ 257 30 Mm Thick Shutter 258 Commercial Veneer Both Side 259 Decorative Teakveneer One Side 260 Providing And Fixing Fully Paneled Double Leaf Shutter For Doors As Per Approved Design And Drawing With Approved Ordinary C.P. / Oxidized Steel Fittings As Per Annexure – A’ And Width Of Styles & Top Rails Of 100Mm And Lock Rails Width Of 150Mm And Bottom Rails Of 200Mm Width Including Teak Wood Beading Of Size 19Mmx12mm On Both Faces Complete : 261 30 Mm Thick Ghana Teak Wood Grade - I 262 Wire Gauge 24 Gauge 14 Mesh Of Is Designation 85 Gauge Wires Of Dia 0.56 Mm Panels 263 Demolishing Cement Concrete Including Disposal Of Material Within 50 Meter Lead : 264 1:3:6 Or Richer Mix. 265 Demolishing Of R.C.C. Work Including Stacking Of Steel Bars And Disposal Of Unserviceab Le Material Within 50 Meters Lead. 266 Demolishingbrickwork Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Meters Lead. 267 In Cement Mortar. 268 Structural Steel Work In Single Section Fixed With Or Without Connecting Plate Including Cutting, Hoisting ( Height Upto 10 M ) , Fixing In Position And Applying A Priming Coat Of Approved Steel Primer All Complete. 269 Providing And Fixing T-Iron Frames For Doors, Windows And Ventilators Of Mild Steel Tee-Sections, Joints Mitred And Welded With 15X3 Mm Lugs 10 Cm. Long Embedded In Cement Concrete Blocks 15X10x10 Cm. Of 1:2:4 ( 1-Cement:2-Coarse Sand:4-Graded Stone Aggregate 20 Mm Nominal Size ) Or With Wooden Plugs And Screws Or Rawl Plugs And Screws Or With Fixing Clips Or With Bolts And Nuts As Required Including Fixing Of Necessary Butt Hinges And Screws And Applying A Priming Coat Of Approved Steel Primer. 270 Providing And Fixing Steel Gate Grating And Grills Made Of Angles, Tees, Square Bars Or Other Flats Black Pipe With Holdfast And Fittings Complete As Per Design And Drawing Including Cutting Welding And Fabrication With Priming Coat Of Red Oxide. 271 Providing & Fixing Ms Sheet Single Leaf Door Shutters In Angle Iron Frame 35X35x5 Mm Suitablly Diagonally Braced With 25X3mm Flat Ironabove And Below Lock Rail Of Size 50X5 Mm Beading Extra Includingall Fittings, As Per Direction Of Engg. Incharge But Excluding Coes Of Chokhats Including Two Coats Of Anti Corrastie Red Oxide Primer Panit. 272 Ms Sheet 18 Swg 273 Providing & Fixing Steel Glazed Doors, Windows And Ventilators With Shutters Of Standred Rolled Steel Section Joint Mitred And Welded With Steel 13X3mm Lugs 10 Cm. Long Embedded In Cement Concrete Blocks 15X10x10 Cm. Of 1:2:4 ( 1-Cement:2-Coarse Sand:4-Graded Stone Aggregate 20 Mm Nominal Size ) Or With Wooden Plugs And Screws Or Rawl Plugs And Screws Or With Fixing Clips Or With Bolts And Nuts As Required, Including Providing And Fixing Of Plain Glass Panes 4Mm Thick With Copper Glazing Clips And Special Metal-Sash Putty Of Approved Make, Or Metal Beading With Screws Complete Including Priming Coat Of Approved Steel Primer, Excluding The Cost Of Metal Beading And Other Fittings Except Necessary Hinges Of Pivots Steel Handles And Peg Stay Etc. As Required. 274 Patially Fixed And Partially Openable Fixed Area Not Exceed 33% 275 Supplying And Fixing Fixed Wire Gauge To The Metal Frame Of Rolled Section By Metal Beading 20X3mm With Suitable Screw At Not Exceeding 150 Mm Distance. 276 14 Mesh X 24 Gauge 277 Providing And Fixing 20 Mm Thick Precast Terrazo Tiles Of Approved Make, With Marble Chips Of Size Upto 6Mm Laid Over Roof With Neat Cement Slurry Mixed With Pigment To Match The Shade Of The Tiles, Including Cutting , Grinding Rubbing With Machinecomplete On 20 Mm Thick Bed Of Cement Sand Mortar 1 : 4. 278 Removing White Or Colour Wash By Scrapping And Sand Papering And Preparing The Surface Smooth Including Necessary Repairs To Scratches By Sandal / Loi. ( Only For Colour Changing Only ) . 279 Distempering With Dry Distemper Of Approved Brand And Shade ( Two Or More Coats ) And Of Required Shade On New Work, Over And Including, Priming Coat Of Whiting To Give An Even Shade Including All Scaffolding. 280 Providing & Fixing 12 Mm Thick Tegular Edge Glass Fibre Reinforced Gypsum False Ceiling Tiles Of Size 595 X 595 Mm In True Horizontal Level Suspended On Inter Locking Metal Grid Of Hot Dipped Galvanised Steel Sections ( Galvanized @ 170 Gsm / Sqm. ) Consisting Of Main “T” Runner With Suitably Spaced Joints To Get Required Length And Of Size 24X38mm Made From 0.30Mm Thick ( Minimum ) Sheet Spaced At 1200Mm Center To Center And Cross “T” Of Size 24X25mm Made Of 0.30Mm Thick ( Minimum ) Sheet, 1200Mm Long Spaced Between Main “T” At 600Mm Center To Center To Form A Grid Of 1200X600 Mm And Secondary Cross “T” Of Length 600Mm And Size 24X25mm Made Of 0.30 Mm Thick ( Minimum ) Sheet To Be Interlocked At Middle Of The 1200X600mm Panel To Form Grids Of 600X600mm And Wall Angle Of Size 21X21x0.30 Mm And Laying False Ceiling Tiles Of Approved Texture In The Grid Including, Wherever, Required, Cutting / Making, Opening For Services Like Diffusers, Grills, Light Fittings, Fixtures, Smoke Detectors Etc. Main “T” Runners To Be Suspended From Ceiling Using Gi Slotted Cleats Fixed To Ceiling With 6 Mm Dia And 50Mm Long Dash Fasteners, 4Mm Gi Adjustable Rods With Galvanised Level Clips Spaced At 1200Mm Center To Center Along Main T, Bottom Exposed Width Of 24Mm Of All T-Sections Shall Be Pre-Painted With Polyester Paint, All Complete At All Heights As Per Specifications Drawings And As Directed By Engineer-In-Charge. 281 Finishing Wall With Water Proofing Cement Paint Of Approved Brand And Manufacture And Or Required Shade To Give An Even Shade Including All Scaffolding: 282 New Work ( Two Or More Coats Applied @ 3.84 Kg / 10 Sqm ) . 283 Old Work ( One Or More Coats ) . 284 Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture Togive An Even Shade : 285 Two Or More Coats On New Work. 286 One Or More Coats On Old Work. 287 Kota Stone Slab Flooring 25 Mm Thick Over 20 Mm ( Average ) Thickbase Laid Over And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab Including Rubbing And Polishing Completewith Base Of Cement Mortar 1 : 4 ( 1 Cement : 4 Coarse Sand ) 288 For Area Of Each Slab Up To 900 Sq. Cm 289 For Area Of Each Slab Up To 901 To 2000Sq. Cm 25 Mm Thick Slab. 290 Providing And Laying In Position Cement Concrete Including Curing Compaction Etc. Of Specified Grade Excluding The Cost Of Centering And Shuttering =All Up To Plinth Level 291 M15 Grade Nominal Mix 1: 2: 4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stoneaggregate 20Mm Nominal Size ) . 292 Add 10 % For Water Supply And Sainatry Works 293 Add 10 % For Electric Works 294 Horticulture 295 Cutting Of Trees, Including Cutting Of Trunks, Branches And Removal Of Stumps, Roots, Stacking Of Serviceable Material With All Lifts And Up To A Lead Of 1000 Mtrs And Earth Filling In The Depression / Pit To Required Compaction As Per Mort&H Specification Clause 201. ( Measurment Of Girth To Be Done At Height Of 1 M Above Ground Level ) 296 Girth From 300 Mm To 600 Mm 297 Clearing Grass And Removal Of Rubbish ( Maximum 150Mm ) By Manual Means And Disposal At A Lead Of 50 Metres As Per Mort&H Specification Clause 201. 298 Supply Of Dry Manure Including Loading Unloading, Transportation & Stacking At Site. 299 From Yard Manure ( Organic ) 300 Compost 301 Goat Dungmanure 302 Supply & Stacking Good Earth At Site Complete Including Loading Unloading & Transporation Etc. 303 Supply Of Insecticides & Pesticides At Store In Dust / Liquid Form Complete 304 Methly Prathion 2% 305 Supply Of Different Varities Of Tree / Shrubs / Climbers According To Height And Age Of The Plant At Site Including Loading / Unloading & Transportation Etc. Complete: 306 Different Flowing Plants 900 Mm To 1500 Mm 307 Different Varrities Of Shrubs 600 Mm To 900 Mm 308 Different Varrities Of Climbers 900 Mm To 1500 Mm 309 Laying Of Lawns Including Ploughing Levelling Breaking Of Clods Manuring & Removal Of Stones Etc. ( Cost Of Manure Of Extra Good Earth To Be Paid Seperatley ) Maintenance Of Lawns For 30 Days Of More Till The Grass Forms A Thick Lawns Free From Weeds & Fit For Mowing In The Duration Of Planting If Lawn Die Some Where The Contractor Will Replant It At His Own Cost. 310 In Rows 7.5 Cms. Apart In Either Direction 311 Renovating Lawns Including Weeding Cheeling The Grass Forking The Ground Top Dressing With Manure. Mixing The Same With Forked Soil Watering Maintaing The Lawns For 30 Days Or More Till Grass Forms A Thick Lawns Free From Weeds & Fit For Mowing & Disposal Of Rubbish As Directed. 312 Road And Drainage Work 313 Providing, Laying, Spreading And Compacting Of Granular Sub-Base By Providing Close Graded Material ( Table 400-1 ) , Spreading In Uniform Layers With Motor Grader On Prepared Surface, Mixing By Mix In Place Method With Rotavator At Omc, And Compacting With Vibratory Roller To Achieve The Desired Density, Complete As Per Mort&H Specification Clause - 401 Including All Material, Labour, Machinery, Lighting, Guarding And Maintenance Of Diversion. 314 Grading - Ii Material 315 Providing Laying, Spreading And Compacting Stone Aggregates Of Specific Sizes As Per Table 400-7 To Water Bound Macadam Specification Including Spreading In Uniform Thickness; Hand Packing, Rolling With Power Roller 8-10 Tonnes, In Stages To Proper Grade And Camber, Applying And Brooming Requisite Type Of Screening ( Table 400-8 ) Binding Materials To Fill Up The Interstices Of Coarse Aggregates, Watering ( With Water Browser ) And Compacting To Required Density, Making Necessary Earthen Bund To Protect Edges As Per Clause 404 Of Mort&H Specification Including All Material, Labour, Machinery, Lighting, Guarding And Maintenance Of Diversion Complete 316 Crusher Broken -Grade-Ii ( 63-45Mm ) 317 Providing And Applying Primer Coat Over Prepared Surface Of Granular Base With Bitumen Emulsion As Per Is : 8887 And Approved Quality @ 0.6 Kg / Sqm With The Help Of Spray Set Fitted On Bitumen Container ( Boiler ) After Cleaning The Surface Including Removing Of Binding Material And Other Foreign Matter With Wire Brushes And Small Picks, Sweeping With Brooms Or Soft Brushes And Finally Dusting With Old Gunny Bags And Compressed Air To Receive Bituminous Treatment Complete As Per Clause 502 Of Mort&H Specification Including All Material, Labour, Machinery, Lighting, Guarding And Maintenance Of Diversion. 318 Providing And Laying Open Graded Premix Carpet 20Mm Thick ( Compacted ) , On Prepared Surface In A Single Course As Wearing Course, Composed Of Specified Graded Crushed Stone Aggregate As Per Table 500-23, Premixed With Bituminous Binder @ 14.60 Kg / 10Sqm ( Including Cost Of Anti-Stripping Compound Wherever Required ) , Including Loading Of Material With F.E. Loader, Hot Mixing Of Stone Aggregate And Bitumen In Computerised Hot Mix Plant, Transporting The Mixed Material By Tippers To Paver And Laying With Paver Finisher Fitted With Electronic Sensor Control To The Required Level And Grade, Compacting Smooth Wheeled Roller 8-10 Tonne Capacity And Finishing To Required Level To Achieve The Desired Density As Per Clause 511 Of Mort&H Specification Including All Material, Labour, Machinery, Lighting, Guarding And Maintenance Of Diversion But Excluding Cost Of Tack Coat / Seal Coat. 319 With Bitumen Vg-Grade 30 320 Providing And Applying Premixed Seal Coat Type B Comprising Of Thin Application Of Fine Aggregate 0.06 Cum / 10 Sqm Premix With Bitumen Binder @ 6.8 Kg / 10 Sqm ( Including Cost Of Anti-Stripping Compound Wherever Required ) Laying With Paver Finisher With Electronic Sensor Control And Rolling With Power Roller 8-10 Tonne Complete As Per Clause 513 Of Mort&H Specification Including All Material, Labour, Machinery, Lighting, Guarding And Maintenance Of Diversion. 321 With Bitumen Vg-Grade 30 322 Earth Work In Excavation By Mechanical Means ( Hydraulic Excavator ) / Manual Means In Foundation Trenches Or Drains ( Not Exceeding 1.5 M In Width Or 10 Sqm On Plan ) Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Taking Out The Excavated Soil And Depositing And Refilling Of Jhiri With Watering & Ramming And Disposal Of Surplus Excavated Soil As Directed With In A Lead Of 50 Meter.All Kinds Of Soils 323 Random Rubble Stone Masonary For Foundation And Plinth In Cement Sand Mortar Above 30 Cm. Thick Wall In : 324 Cement Mortar 1:6 ( 1-Cement:6-Sand ) . 325 Brick Work With F.P.S. Bricks Of Class Designation 75 Infoundation And Plinth In: 326 Cement Mortar 1:6 ( 1-Cement:6-Coarse Sand ) . 327 Providing And Laying Reinforced Cement Concrete Pipe Np4 / Prestrssed Concrete Pipe For Culverts Including Jointing Ends And Fixing Collar With Cement Mortar 1:2 Complete As Per Clause 1000 & 2900 Of Mort&H Specification Including All Material, Labour Form Work, Machinery. 328 200 Mm Internal Diameter 329 Providing And Fixing Of Reinforced Ferro-Cement Drain Covers Designed For A Class Loading Duly Marked On Cover With Adequate Steel Reinforcement Having Thickness 75Mm To 150Mm Anti Corrosive Bitumen Painted M.S. Plate , Rim And M.S. Lifting Hooks, Admixtures Like Plasticizer, Bond Improving Compound, Shrinkage, Resistance Compound, Abrasion Resistant Complete As Per Approved Design Etc 330 Standard Size 600X800mm ( 75Mm Thick ) For Span 300 To 450Mm 331 Providing And Laying Lean Cement Concrete 1:4:8 In Sub- Base Over A Prepared Sub-Grade With Coarse And Fine Aggregate Conforming To Is: 383, The Size Of Coarse Aggregate Not Exceeding 25 Mm, Aggregate Cement Ratio Not To Exceed 15:1, Aggregate Gradation After Blending To Be As Per Table 600-1, Cement Content Not To Be Less Than 150 Kg / Cum, Optimum Moisture Content To Be Determined During Trial Length Construction, Concrete Strength Not To Be Less Than 10 Mpa At 7 Days, Mixed In A Batching Plant, Transported To Site, Laid With A Paver With Electronic Sensor, Compacting With 8-10 Tonnes Vibratory Roller, Finishing And Curing Complete As Per Clause 601, 112 Of Mort&H Specification Including All Material, Labour, Machinery, Lighting, Guarding And Maintenance Of Diversion 332 Providing And Laying Un-Reinforced, Plain Cement Concrete Mix With Concrete Mixer & Vibrator Pavement Over A Prepared Sub Base With 43 Grade Cement , Coarse And Fine Aggregate Conforming To Is: 383, Maximum Size Of Coarse Aggregate Not Exceeding 25 Mm, Mixed As Per Approved Mix Design, Laid, Spread, Compacted And Finished In A Continuous Operation Including Provision Of Contraction, Expansion, Construction And Longitudinal Joints Etc Including All Material, Labour, Machinery, Lighting, Guarding And Maintenance Of Diversion. 333 Pcc M-30 334 Campus Lighting 335 Supply And Erection Of Octagonal Pole Of Following Length And Dimension As Per Table-3 With Base Plate On The Cement Concrete Foundation Of M-15 / M-20 Grade ( 1:1.5:3 ) With The Help Of Anchor Bolts Of Grade 6.8 ( Is 1367 P Iii ) . The Pole Shall Be Made Of S-355Jo Grade Steel Sheet , Folded Lengthwise To Obtained Octagonal Shape, Having Single Longitudinal Seam Weld And Hot Dipped Galvanised Internally & Externally In Accordance With Is 2629. The Pole Shall Have A Weatherproof Flush Door And Locking Arrangements. The Complete Work Shall Be Supervised And Certified By The Manufacturers For Satisfactory Supply, Erection, Testing And Commissioning. 336 7 Mtr 337 Supply, Erection And Fixing Of Hot Dipped Galvanised Overhang ( 60 X 3.25 Mm ) With Cap ( 250 X 137.9 X 4.05 Mm ) Over The Existing Poles 338 Single Arm Overhang 339 P & F Of Ip 65 / 67 Protected Led Flood Light System With Aluminium Housing, 3 X 1W, 220V, 50Hz Led Lamps With Dynamic Color Changing Capability Available In Quick Connecting Cable Coupled With Various Mounting Accessories. Ability To Create 16.7 Million Uniform, Smooth And Brilliant Colors Without Revealing Any Lamp Image. Available In 5 Colors – Amber, Green, Blue, Red And White. 340 Providing & Laying Xlpe Insulated / P.V.C. Sheathed Cable Of 1.1 Kv Grade With Aluminium Conductor Armoured Of Is:7098-I / 1554-1 Approved Makein Ground As Per Is:1255 Including Excavation Of 30Cmx75cm Size Trench, 25 Cm Thick Underlayer Ofsand, Second Class Bricks Covering, Refilling Earth, Compaction Of Earth, Making Necessary Connection, Testing Etc. As Required Of Size 341 10.0 Sq.Mm2 Cor 342 Add 5% Over Head 343 Repair Of Pump House Building At Churu, Bhaleri Like Repair Of Plaster, Floor, Roof, Doors, Windows, Colour Washing, Painting Etc. 344 Earth Work In Excavation By Mechanical Means ( Hydraulic Excavator ) / Manual Means In Foundation Trenches Or Drains ( Not Exceeding 1.5 M In Width Or 10 Sqm On Plan ) Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Taking Out The Excavated Soil And Depositing And Refilling Of Jhiri With Watering & Ramming And Disposal Of Surplus Excavated Soil As Directed With In A Lead Of 50 Meter.All Kinds Of Soils 345 Random Rubble Stone Masonary For Foundation And Plinth In Cement Sand Mortar Above 30 Cm. Thick Wall In : 346 Cement Mortar 1:6 ( 1-Cement:6-Sand ) . 347 Brick Work With F.P.S. Bricks Of Class Designation 75 Infoundation And Plinth In: 348 Cement Mortar 1:6 ( 1-Cement:6-Coarse Sand ) . 349 Brick Work With F.P.S. Bricks Of Class Designation 75 In Superstructure Above Plinth Level Upto Floor V Level In All Shapes And Sizes In : 350 Cement Mortar 1:6 ( 1-Cement:6-Coarse Sand ) . 351 Repairs To Plaster Of Thickness 12Mm To 20Mm In Patches Of Area 2.5 Sq. Metres And Under Including Cutting The Patch In Proper Shape, Raking Out Joints And Preparing And Plastering The Surface Of The Walls Complete Including Disposal Of Rubbish To The Dumping Ground Within 50 M Lead : With Cement Mortar 1 :4 ( 1 Cement : 4 Fine Sand ) 352 Scraping Old Surface And Redoing Lime Loi Or Sandla. 353 Patch Repair To Cement Concrete Floor Including Digging Out Old Floor In Regular Shape And Removal Of Rubbish Curing Etc. Complete In All Respects. 354 Renewing Glass Panes, With Puty And Nails Wherever Necessary: 355 5.5 Mm Thick Plain Glass Panes. 356 Providing And Fixing 16 Mm M.S. Fan Clamps Of Standard Shape And Size In R.C.C. Slab / Stone Slab Roofing Including Cutting Chase And Making Good And Painting Exposed Portion Of The Clamps Complete: 357 In Existing Roof. 358 Chopping Loose And Cracked Concrete To Required Depth, Cleaning The Exposed Surface Of Steel And Concrete With Wire Brush And Sand Blasting, Clening With A Jet Of Water / Air As Necessary And Getting It Dried With Compressed Air Including All Scaffolding: 359 Depth 50 Mm To 75 Mm. 360 Depth 75 Mm To 100 Mm. 361 Repairofdoor, Windowshuttersincludingcostofmaterialandlabourforchangeofdamaged : 362 Style / Rail Of Teak Wood 30Mm Thick / Aluminium Section 363 4Wide 364 6 Wide 365 Panel By 366 Shuttering Ply - 9Mm Thick ( Commercial ) 367 Wire Gauge 14 Mesh X 24 Gauge 368 Plain Glass Panes 4Mm Thick 369 Aldrop Of Mild Steel 370 12 Long X12mm Dia 371 8 Long X 10Mm Dia 372 Stopper Of Aluminium With 373 Single Rubber Gutka 374 Double Rubber Gutka 375 Door Springs Of Mild Steel 376 Steel Hinges 377 For Wooden Chowkhat 3 Size. 378 For Wooden Chowkhat 4 Size 379 For Stone Chowkhat , 4Size 380 Mild Steel Tower Bolt 6 Long 381 Steel Locking Bolt 382 Steel Handle 6 Size 383 Providing And Laying In Position Cement Concrete Including Curing Compaction Etc. Of Specified Grade Excluding The Cost Of Centering And Shuttering =All Up To Plinth Level 384 M15 Grade Nominal Mix 1: 2: 4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stoneaggregate 20Mm Nominal Size ) . 385 M10 Grade Nominal Mix 1: 3: 6 ( 1 Cement : 3 Coarse Sand : 6 Graded Stoneaggregate 20Mm Nominal Size ) . 386 Making Plinth Protection 50Mm Thick Of Cement Concrete 1:3:6 ( 1 Cement : 3 Coarse Sand : 6 Graded Stone Aggre -Gate 20 Mm Nominal Size ) Over 75Mm Bed Of Dry Brick Ballast 40Mm Nominal Size Well Rammed And Consolidated And Grouted With Fine Sand Including Finishing The Top Smooth. 387 Providing And Laying In Position Specified Grade Ofcement Concrete For Rcc Structural Elements Upto Floor Five Level Including Curing, Compaction, Finishing With Rendering In Cement Sand Mortar 1:3 ( 1 Cement: 3 Coarse Sand ) And Making Good The Joints And Cost Of Plastizers ( If Required ) Excluding The Cost Of Centering, Shuttering And Reinforcementfor Walls ( Any Thickness ) Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc. M20 Grade Nominal Mix / Design Mix 388 Centering & Shuttering With Plywood Or Steel Sheets Including Strutting, Propping Bracing Both Ways With Steel Propsand Removal Of Formwork For Upto Floor Five Level For : 389 Suspended Floors, Roofs, Landings, Staircases, Balconies, Girders, Cantilevers, Bands , Coping, Bed Plates, Anchor Blocks, Sills, Chhajjas Lintel, Beam Etc. 390 Providing And Fabricating Reinforcement For R.C.C. Work Including Straightening, Cutting, Bending, Placing In Position And Binding ( Including Cost Of Binding Wire ) All Complete Up To Floor Five Level. 391 Hot Rolled Deformed Bars ( Is : 1139 ) . 392 Plaster On New Surface On Walls In Cement Sand Mortar 1:6 Including Racking Of Joint Etc. Complete Fine Finished: 393 20 Mm Thick. 394 Brick Work With F.P.S. Bricks Of Class Designation 75 In Superstructure Above Plinth Level Upto Floor V Level In All Shapes And Sizes In : 395 Cement Mortar 1:6 ( 1-Cement:6-Coarse Sand ) . 396 Half Brick Masonry In Superstructure , Above Plinth Level Upto Floor Fivelevelusing F.P.S. Bricks Of Designation 75 397 Cement Mortar 1:4 ( 1-Cement:4-Coarse Sand ) . 398 Providing And Fixing Ist Quality Ceramic Glazed Wall Tiles Conforming To Is : 15622 ( Thickness To Be Specified By The Manufacture ) Of Approved Make In All Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Engineer In Charge In Skiriting, Risers Of Steps And Dados Over 12 Mm Thick Bed Of Cement Mortar 1:3 ( 1 Cement : 3 Coarse Sand ) And Jointing With Grey Cement Slurry @ 3.3 Kg Per Sqm Including Pointing In White Mixed With Pigment Of Matching Shade Complete. 399 Category - I : Kajariya, Jhonson, Orient, Somani Make Etc. 400 Providing And Fixing External Grade Board Solid Core Single Leaf Flush Door Shutters Isi 2202-67 Marked Using Phenol Formal, Dehydreresin In Glue Both Sides With Approved Steel Fittings Complete As Per Annexure ‘A’ 401 30 Mm Thick Shutter 402 Commercial Veneer Both Side 403 Providing And Fixing Fully Paneled Double Leaf Shutter For Doors As Per Approved Design And Drawing With Approved Ordinary C.P. / Oxidized Steel Fittings As Per Annexure – A’ And Width Of Styles & Top Rails Of 100Mm And Lock Rails Width Of 150Mm And Bottom Rails Of 200Mm Width Including Teak Wood Beading Of Size 19Mmx12mm On Both Faces Complete : 404 30 Mm Thick Ghana Teak Wood Grade - I 405 Wire Gauge 24 Gauge 14 Mesh Of Is Designation 85 Gauge Wires Of Dia 0.56 Mm Panels 406 Demolishing Cement Concrete Including Disposal Of Material Within 50 Meter Lead : 407 1:3:6 Or Richer Mix. 408 Demolishing Of R.C.C. Work Including Stacking Of Steel Bars And Disposal Of Unserviceab Le Material Within 50 Meters Lead. 409 Providing And Fixing Steel Gate Grating And Grills Made Of Angles, Tees, Square Bars Or Other Flats Black Pipe With Holdfast And Fittings Complete As Per Design And Drawing Including Cutting Welding And Fabrication With Priming Coat Of Red Oxide. 410 Providing & Fixing Ms Sheet Single Leaf Door Shutters In Angle Iron Frame 35X35x5 Mm Suitablly Diagonally Braced With 25X3mm Flat Ironabove And Below Lock Rail Of Size 50X5 Mm Beading Extra Includingall Fittings, As Per Direction Of Engg. Incharge But Excluding Coes Of Chokhats Including Two Coats Of Anti Corrastie Red Oxide Primer Panit. 411 Ms Sheet 18 Swg 412 Providing & Fixing Steel Glazed Doors, Windows And Ventilators With Shutters Of Standred Rolled Steel Section Joint Mitred And Welded With Steel 13X3mm Lugs 10 Cm. Long Embedded In Cement Concrete Blocks 15X10x10 Cm. Of 1:2:4 ( 1-Cement:2-Coarse Sand:4-Graded Stone Aggregate 20 Mm Nominal Size ) Or With Wooden Plugs And Screws Or Rawl Plugs And Screws Or With Fixing Clips Or With Bolts And Nuts As Required, Including Providing And Fixing Of Plain Glass Panes 4Mm Thick With Copper Glazing Clips And Special Metal-Sash Putty Of Approved Make, Or Metal Beading With Screws Complete Including Priming Coat Of Approved Steel Primer, Excluding The Cost Of Metal Beading And Other Fittings Except Necessary Hinges Of Pivots Steel Handles And Peg Stay Etc. As Required. 413 Patially Fixed And Partially Openable Fixed Area Not Exceed 33% 414 Supplying And Fixing Fixed Wire Gauge To The Metal Frame Of Rolled Section By Metal Beading 20X3mm With Suitable Screw At Not Exceeding 150 Mm Distance. 415 14 Mesh X 24 Gauge 416 Providing And Fixing 20 Mm Thick Precast Terrazo Tiles Of Approved Make, With Marble Chips Of Size Upto 6Mm Laid Over Roof With Neat Cement Slurry Mixed With Pigment To Match The Shade Of The Tiles, Including Cutting , Grinding Rubbing With Machinecomplete On 20 Mm Thick Bed Of Cement Sand Mortar 1 : 4. 417 Removing White Or Colour Wash By Scrapping And Sand Papering And Preparing The Surface Smooth Including Necessary Repairs To Scratches By Sandal / Loi. ( Only For Colour Changing Only ) . 418 Distempering With Dry Distemper Of Approved Brand And Shade ( Two Or More Coats ) And Of Required Shade On New Work, Over And Including, Priming Coat Of Whiting To Give An Even Shade Including All Scaffolding. 419 Finishing Wall With Water Proofing Cement Paint Of Approved Brand And Manufacture And Or Required Shade To Give An Even Shade Including All Scaffolding: 420 New Work ( Two Or More Coats Applied @ 3.84 Kg / 10 Sqm ) . 421 Old Work ( One Or More Coats ) . 422 Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture Togive An Even Shade : 423 Two Or More Coats On New Work. 424 One Or More Coats On Old Work. 425 Cement Concrete Flooring 1:2:4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate ) Finished With A Floating Coat Of Neat Cement Including Cement Slurry, Making Of Lines Or Groove Etc Complete But Excluding The Cost Of Nosing Of Steps Etc. Complete. 426 40 Mm Thick With 20 Mm Thick Nominal Size Aggregate. 427 75 Mm Thick With 20 Mm Thick Nominal Size Aggregate. 428 Kota Stone Slab Flooring 25 Mm Thick Over 20 Mm ( Average ) Thickbase Laid Over And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab Including Rubbing And Polishing Completewith Base Of Cement Mortar 1 : 4 ( 1 Cement : 4 Coarse Sand ) 429 For Area Of Each Slab Up To 900 Sq. Cm 430 For Area Of Each Slab Up To 901 To 2000Sq. Cm 25 Mm Thick Slab. 431 Providing And Laying In Position Cement Concrete Including Curing Compaction Etc. Of Specified Grade Excluding The Cost Of Centering And Shuttering =All Up To Plinth Level 432 M15 Grade Nominal Mix 1: 2: 4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stoneaggregate 20Mm Nominal Size ) . 433 Add 5 % For Water Supply And Sainatry Works 434 Add 10 % For Electric Works 435 Horticulture 436 Cutting Of Trees, Including Cutting Of Trunks, Branches And Removal Of Stumps, Roots, Stacking Of Serviceable Material With All Lifts And Up To A Lead Of 1000 Mtrs And Earth Filling In The Depression / Pit To Required Compaction As Per Mort&H Specification Clause 201. ( Measurment Of Girth To Be Done At Height Of 1 M Above Ground Level ) 437 Girth From 300 Mm To 600 Mm 438 Clearing Grass And Removal Of Rubbish ( Maximum 150Mm ) By Manual Means And Disposal At A Lead Of 50 Metres As Per Mort&H Specification Clause 201. 439 Supply Of Dry Manure Including Loading Unloading, Transportation & Stacking At Site. 440 From Yard Manure ( Organic ) 441 Compost 442 Goat Dungmanure 443 Supply & Stacking Good Earth At Site Complete Including Loading Unloading & Transporation Etc. 444 Supply Of Insecticides & Pesticides At Store In Dust / Liquid Form Complete 445 Methly Prathion 2% 446 Supply Of Different Varities Of Tree / Shrubs / Climbers According To Height And Age Of The Plant At Site Including Loading / Unloading & Transportation Etc. Complete: 447 Different Flowing Plants 900 Mm To 1500 Mm 448 Different Varrities Of Shrubs 600 Mm To 900 Mm 449 Different Varrities Of Climbers 900 Mm To 1500 Mm 450 Laying Of Lawns Including Ploughing Levelling Breaking Of Clods Manuring & Removal Of Stones Etc. ( Cost Of Manure Of Extra Good Earth To Be Paid Seperatley ) Maintenance Of Lawns For 30 Days Of More Till The Grass Forms A Thick Lawns Free From Weeds & Fit For Mowing In The Duration Of Planting If Lawn Die Some Where The Contractor Will Replant It At His Own Cost. 451 In Rows 7.5 Cms. Apart In Either Direction 452 Renovating Lawns Including Weeding Cheeling The Grass Forking The Ground Top Dressing With Manure. Mixing The Same With Forked Soil Watering Maintaing The Lawns For 30 Days Or More Till Grass Forms A Thick Lawns Free From Weeds & Fit For Mowing & Disposal Of Rubbish As Directed. 453 Road And Drainage Work 454 Providing, Laying, Spreading And Compacting Of Granular Sub-Base By Providing Close Graded Material ( Table 400-1 ) , Spreading In Uniform Layers With Motor Grader On Prepared Surface, Mixing By Mix In Place Method With Rotavator At Omc, And Compacting With Vibratory Roller To Achieve The Desired Density, Complete As Per Mort&H Specification Clause - 401 Including All Material, Labour, Machinery, Lighting, Guarding And Maintenance Of Diversion. 455 Grading - Ii Material 456 Providing Laying, Spreading And Compacting Stone Aggregates Of Specific Sizes As Per Table 400-7 To Water Bound Macadam Specification Including Spreading In Uniform Thickness; Hand Packing, Rolling With Power Roller 8-10 Tonnes, In Stages To Proper Grade And Camber, Applying And Brooming Requisite Type Of Screening ( Table 400-8 ) Binding Materials To Fill Up The Interstices Of Coarse Aggregates, Watering ( With Water Browser ) And Compacting To Required Density, Making Necessary Earthen Bund To Protect Edges As Per Clause 404 Of Mort&H Specification Including All Material, Labour, Machinery, Lighting, Guarding And Maintenance Of Diversion Complete 457 Crusher Broken -Grade-Ii ( 63-45Mm ) 458 Providing And Applying Primer Coat Over Prepared Surface Of Granular Base With Bitumen Emulsion As Per Is : 8887 And Approved Quality @ 0.6 Kg / Sqm With The Help Of Spray Set Fitted On Bitumen Container ( Boiler ) After Cleaning The Surface Including Removing Of Binding Material And Other Foreign Matter With Wire Brushes And Small Picks, Sweeping With Brooms Or Soft Brushes And Finally Dusting With Old Gunny Bags And Compressed Air To Receive Bituminous Treatment Complete As Per Clause 502 Of Mort&H Specification Including All Material, Labour, Machinery, Lighting, Guarding And Maintenance Of Diversion. 459 Providing And Laying Open Graded Premix Carpet 20Mm Thick ( Compacted ) , On Prepared Surface In A Single Course As Wearing Course, Composed Of Specified Graded Crushed Stone Aggregate As Per Table 500-23, Premixed With Bituminous Binder @ 14.60 Kg / 10Sqm ( Including Cost Of Anti-Stripping Compound Wherever Required ) , Including Loading Of Material With F.E. Loader, Hot Mixing Of Stone Aggregate And Bitumen In Computerised Hot Mix Plant, Transporting The Mixed Material By Tippers To Paver And Laying With Paver Finisher Fitted With Electronic Sensor Control To The Required Level And Grade, Compacting Smooth Wheeled Roller 8-10 Tonne Capacity And Finishing To Required Level To Achieve The Desired Density As Per Clause 511 Of Mort&H Specification Including All Material, Labour, Machinery, Lighting, Guarding And Maintenance Of Diversion But Excluding Cost Of Tack Coat / Seal Coat. 460 With Bitumen Vg-Grade 30 461 Providing And Applying Premixed Seal Coat Type B Comprising Of Thin Application Of Fine Aggregate 0.06 Cum / 10 Sqm Premix With Bitumen Binder @ 6.8 Kg / 10 Sqm ( Including Cost Of Anti-Stripping Compound Wherever Required ) Laying With Paver Finisher With Electronic Sensor Control And Rolling With Power Roller 8-10 Tonne Complete As Per Clause 513 Of Mort&H Specification Including All Material, Labour, Machinery, Lighting, Guarding And Maintenance Of Diversion. 462 With Bitumen Vg-Grade 30 463 Earth Work In Excavation By Mechanical Means ( Hydraulic Excavator ) / Manual Means In Foundation Trenches Or Drains ( Not Exceeding 1.5 M In Width Or 10 Sqm On Plan ) Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Taking Out The Excavated Soil And Depositing And Refilling Of Jhiri With Watering & Ramming And Disposal Of Surplus Excavated Soil As Directed With In A Lead Of 50 Meter.All Kinds Of Soils 464 Random Rubble Stone Masonary For Foundation And Plinth In Cement Sand Mortar Above 30 Cm. Thick Wall In : 465 Cement Mortar 1:6 ( 1-Cement:6-Sand ) . 466 Brick Work With F.P.S. Bricks Of Class Designation 75 Infoundation And Plinth In: 467 Cement Mortar 1:6 ( 1-Cement:6-Coarse Sand ) . 468 Providing And Laying Reinforced Cement Concrete Pipe Np4 / Prestrssed Concrete Pipe For Culverts Including Jointing Ends And Fixing Collar With Cement Mortar 1:2 Complete As Per Clause 1000 & 2900 Of Mort&H Specification Including All Material, Labour Form Work, Machinery. 469 200 Mm Internal Diameter 470 Providing And Fixing Of Reinforced Ferro-Cement Drain Covers Designed For A Class Loading Duly Marked On Cover With Adequate Steel Reinforcement Having Thickness 75Mm To 150Mm Anti Corrosive Bitumen Painted M.S. Plate , Rim And M.S. Lifting Hooks, Admixtures Like Plasticizer, Bond Improving Compound, Shrinkage, Resistance Compound, Abrasion Resistant Complete As Per Approved Design Etc 471 Standard Size 600X800mm ( 75Mm Thick ) For Span 300 To 450Mm 472 Campus Lighting 473 Supply And Erection Of Octagonal Pole Of Following Length And Dimension As Per Table-3 With Base Plate On The Cement Concrete Foundation Of M-15 / M-20 Grade ( 1:1.5:3 ) With The Help Of Anchor Bolts Of Grade 6.8 ( Is 1367 P Iii ) . The Pole Shall Be Made Of S-355Jo Grade Steel Sheet , Folded Lengthwise To Obtained Octagonal Shape, Having Single Longitudinal Seam Weld And Hot Dipped Galvanised Internally & Externally In Accordance With Is 2629. The Pole Shall Have A Weatherproof Flush Door And Locking Arrangements. The Complete Work Shall Be Supervised And Certified By The Manufacturers For Satisfactory Supply, Erection, Testing And Commissioning. 474 7 Mtr 475 Supply, Erection And Fixing Of Hot Dipped Galvanised Overhang ( 60 X 3.25 Mm ) With Cap ( 250 X 137.9 X 4.05 Mm ) Over The Existing Poles 476 Single Arm Overhang 477 P & F Of Ip 65 / 67 Protected Led Flood Light System With Aluminium Housing, 3 X 1W, 220V, 50Hz Led Lamps With Dynamic Color Changing Capability Available In Quick Connecting Cable Coupled With Various Mounting Accessories. Ability To Create 16.7 Million Uniform, Smooth And Brilliant Colors Without Revealing Any Lamp Image. Available In 5 Colors – Amber, Green, Blue, Red And White. 478 Providing & Laying Xlpe Insulated / P.V.C. Sheathed Cable Of 1.1 Kv Grade With Aluminium Conductor Armoured Of Is:7098-I / 1554-1 Approved Makein Ground As Per Is:1255 Including Excavation Of 30Cmx75cm Size Trench, 25 Cm Thick Underlayer Ofsand, Second Class Bricks Covering, Refilling Earth, Compaction Of Earth, Making Necessary Connection, Testing Etc. As Required Of Size 479 10.0 Sq.Mm2 Cor 480 Repair Of Residantialbuilding At Churu, Bhaleri, Like Repair Of Plaster, Floor, Roof, Doors, Windows, Color Washing, Painting Etc. 481 Repair To Brick Masonary In Cement Sand Mortar With Taking Out Of Deceayed From Wall And Replaceing With New Briks.Cement Sand Mortar 1:6. With New Brick. 482 Repairs To Plaster Of Thickness 12Mm To 20Mm In Patches Of Area 2.5 Sq. Metres And Under Including Cutting The Patch In Proper Shape, Raking Out Joints And Preparing And Plastering The Surface Of The Walls Complete Including Disposal Of Rubbish To The Dumping Ground Within 50 M Lead : With Cement Mortar 1 :4 ( 1 Cement : 4 Fine Sand ) 483 Repair To Stone Masonary In Cement Sand Mortar 1:6 With Old And New Stone. 484 Cutting Jhiri Above 75Mmx75mm And Below 150X150 Mm Etc. And Making Good. 485 Scraping Old Surface And Redoing Lime Loi Or Sandla. 486 Renewing Glass Panes, With Puty And Nails Wherever Necessary: 487 5.5 Mm Thick Plain Glass Panes. 488 Renewing Glass Panes With Wooden Fillets Wherever Necessary: 489 5.5 Mm Thick Plain Glass Panes. 490 Providing And Fixing 16 Mm M.S. Fan Clamps Of Standard Shape And Size In R.C.C. Slab / Stone Slab Roofing Including Cutting Chase And Making Good And Painting Exposed Portion Of The Clamps Complete: 491 In Existing Roof. 492 Guniting Damaged R.C.C. Slab, Beams And Columns For Strengthening With Cement Sand Mortar 1:2 ( 1-Cement:2-Sand ) Including Preparing The Surface, Making V Shaped Joints, Cleaning The Reinforcement Bars With Jet Of Potable Water And Drying With Compressed Air, Including Cost Of Centering And Shuttering And Finishing To Match The Existing Surface Etc. Complete, Including Provided M.S. Welded Mesh To Gauge 25 Mm X 25 Mm Framing With Average Thickness Of 25 Mm. 493 Chopping Loose And Cracked Concrete To Required Depth, Cleaning The Exposed Surface Of Steel And Concrete With Wire Brush And Sand Blasting, Clening With A Jet Of Water / Air As Necessary And Getting It Dried With Compressed Air Including All Scaffolding: 494 Depth 50 Mm To 75 Mm. 495 Depth 75 Mm To 100 Mm. 496 Repairofdoor, Windowshuttersincludingcostofmaterialandlabourforchangeofdamaged : 497 Style / Rail Of Teak Wood 30Mm Thick / Aluminium Section 498 4Wide 499 6 Wide 500 Panel By 501 Shuttering Ply - 9Mm Thick ( Commercial ) 502 Wire Gauge 14 Mesh X 24 Gauge 503 Plain Glass Panes 4Mm Thick 504 Aldrop Of Mild Steel 505 12 Long X12mm Dia 506 8 Long X 10Mm Dia 507 Stopper Of Aluminium With 508 Single Rubber Gutka 509 Double Rubber Gutka 510 Door Springs Of Mild Steel 511 Steel Hinges 512 For Wooden Chowkhat 3 Size. 513 For Wooden Chowkhat 4 Size 514 For Stone Chowkhat , 4Size 515 Mild Steel Tower Bolt 6 Long 516 Steel Locking Bolt 517 Steel Handle 6 Size 518 Providing And Laying In Position Cement Concrete Including Curing Compaction Etc. Of Specified Grade Excluding The Cost Of Centering And Shuttering =All Up To Plinth Level 519 M15 Grade Nominal Mix 1: 2: 4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stoneaggregate 20Mm Nominal Size ) . 520 M10 Grade Nominal Mix 1: 3: 6 ( 1 Cement : 3 Coarse Sand : 6 Graded Stoneaggregate 20Mm Nominal Size ) . 521 Making Plinth Protection 50Mm Thick Of Cement Concrete 1:3:6 ( 1 Cement : 3 Coarse Sand : 6 Graded Stone Aggre -Gate 20 Mm Nominal Size ) Over 75Mm Bed Of Dry Brick Ballast 40Mm Nominal Size Well Rammed And Consolidated And Grouted With Fine Sand Including Finishing The Top Smooth. 522 Plaster On New Surface On Walls In Cement Sand Mortar 1:6 Including Racking Of Joint Etc. Complete Fine Finished: 523 20 Mm Thick. 524 Providing And Fixing Expanded Metal Mesh Of Size 20X60 Mm And Strands 3.5 Mm Vide 1.6 Mm Thick Weighing 3.64 Kg. Per Sqm. For Encasing Ofrolledsteel Sections In Beams, Columns And Grillages Excluding Cost Of Hangers. 525 Brick Work With F.P.S. Bricks Of Class Designation 75 In Superstructure Above Plinth Level Upto Floor V Level In All Shapes And Sizes In : 526 Cement Mortar 1:6 ( 1-Cement:6-Coarse Sand ) . 527 Half Brick Masonry In Superstructure , Above Plinth Level Upto Floor Fivelevelusing F.P.S. Bricks Of Designation 75 528 Cement Mortar 1:4 ( 1-Cement:4-Coarse Sand ) . 529 Brick Work In Partition In Super Structure Upto Five Storey 7Cm. Thick ( Brick On Edges ) Using F.P.S. Bricksof Class Designation 75 In : 530 Cement Mortar 1:4 ( 1-Cement:4-Coarse Sand ) . 531 Supplying And Fixing Machine Cut And Polished Stone Shelves, Tands And Sills In Cm 1:3 With Machine Cut Edges: 532 Kota Stone 25 To 30 Mm Thick. 533 Providing And Fixing Granite Stone Slab Mirror Polished And Machine Edge Cut In Walls, Pillars, Steps, Shelves, Sills, Counters. Floors Etc. Laid On 12Mm ( Av. ) Thick Base Of Cement Mortar 1:3 Jointing With White Cement Mortar 1:2 ( 1 White Cement: 2 Marble Dust ) With Pigment To Match The Shade Of The Marble Slab Complete Including Grinding, Rubbing And Polishing Of: 534 Jhunjhunu / Jalore ( Red / Choclate Colour ) 535 Above 3601 Cm2 Slabs 536 Providing And Laying Vitrified Floor Tiles In Different Sizes ( Thickness To Be Specified By The Manufacturer ) With Water Absorption’S Less Than 0.08% And Conforming To Is : 15622 Of Approved Make In All Colours And Shades, Laid On 20Mm Thick Cement Mortar 1:4 ( 1 Cement: 4 Coarse Sand ) Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete. 537 Size Of Tile 60X60 Cm 538 Providing And Fixing Ist Quality Ceramic Glazed Wall Tiles Conforming To Is : 15622 ( Thickness To Be Specified By The Manufacture ) Of Approved Make In All Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Engineer In Charge In Skiriting, Risers Of Steps And Dados Over 12 Mm Thick Bed Of Cement Mortar 1:3 ( 1 Cement : 3 Coarse Sand ) And Jointing With Grey Cement Slurry @ 3.3 Kg Per Sqm Including Pointing In White Mixed With Pigment Of Matching Shade Complete. 539 Category - I : Kajariya, Jhonson, Orient, Somani Make Etc. 540 Providing & Fixing In Cement Sand Mortar 1:4 Single Paitam ( Rebated ) Stone Doors Windows And Ventilator Frames Of Approved Quarry : 541 Size 100X75mm. 542 Size 125X100mm. 543 Providing And Fixing In Cm 1:4 Double Paitam ( Rebated ) Stone Door Window And Ventilator Frames Of Approved Quarry : 544 Size 125 X 100Mm. 545 Providing And Fixing External Grade Board Solid Core Single Leaf Flush Door Shutters Isi 2202-67 Marked Using Phenol Formal, Dehydreresin In Glue Both Sides With Approved Steel Fittings Complete As Per Annexure ‘A’ 546 30 Mm Thick Shutter 547 Commercial Veneer Both Side 548 Decorative Teakveneer One Side 549 Providing And Fixing Fully Paneled Double Leaf Shutter For Doors As Per Approved Design And Drawing With Approved Ordinary C.P. / Oxidized Steel Fittings As Per Annexure – A’ And Width Of Styles & Top Rails Of 100Mm And Lock Rails Width Of 150Mm And Bottom Rails Of 200Mm Width Including Teak Wood Beading Of Size 19Mmx12mm On Both Faces Complete : 550 30 Mm Thick Ghana Teak Wood Grade - I 551 Wire Gauge 24 Gauge 14 Mesh Of Is Designation 85 Gauge Wires Of Dia 0.56 Mm Panels 552 Demolishing Cement Concrete Including Disposal Of Material Within 50 Meter Lead : 553 1:3:6 Or Richer Mix. 554 Demolishing Of R.C.C. Work Including Stacking Of Steel Bars And Disposal Of Unserviceab Le Material Within 50 Meters Lead. 555 Demolishingbrickwork Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Meters Lead. 556 In Cement Mortar. 557 Providing And Fixing T-Iron Frames For Doors, Windows And Ventilators Of Mild Steel Tee-Sections, Joints Mitred And Welded With 15X3 Mm Lugs 10 Cm. Long Embedded In Cement Concrete Blocks 15X10x10 Cm. Of 1:2:4 ( 1-Cement:2-Coarse Sand:4-Graded Stone Aggregate 20 Mm Nominal Size ) Or With Wooden Plugs And Screws Or Rawl Plugs And Screws Or With Fixing Clips Or With Bolts And Nuts As Required Including Fixing Of Necessary Butt Hinges And Screws And Applying A Priming Coat Of Approved Steel Primer. 558 Providing And Fixing Steel Gate Grating And Grills Made Of Angles, Tees, Square Bars Or Other Flats Black Pipe With Holdfast And Fittings Complete As Per Design And Drawing Including Cutting Welding And Fabrication With Priming Coat Of Red Oxide. 559 Providing & Fixing Ms Sheet Single Leaf Door Shutters In Angle Iron Frame 35X35x5 Mm Suitablly Diagonally Braced With 25X3mm Flat Ironabove And Below Lock Rail Of Size 50X5 Mm Beading Extra Includingall Fittings, As Per Direction Of Engg. Incharge But Excluding Coes Of Chokhats Including Two Coats Of Anti Corrastie Red Oxide Primer Panit. 560 Ms Sheet 18 Swg 561 Providing & Fixing Steel Glazed Doors, Windows And Ventilators With Shutters Of Standred Rolled Steel Section Joint Mitred And Welded With Steel 13X3mm Lugs 10 Cm. Long Embedded In Cement Concrete Blocks 15X10x10 Cm. Of 1:2:4 ( 1-Cement:2-Coarse Sand:4-Graded Stone Aggregate 20 Mm Nominal Size ) Or With Wooden Plugs And Screws Or Rawl Plugs And Screws Or With Fixing Clips Or With Bolts And Nuts As Required, Including Providing And Fixing Of Plain Glass Panes 4Mm Thick With Copper Glazing Clips And Special Metal-Sash Putty Of Approved Make, Or Metal Beading With Screws Complete Including Priming Coat Of Approved Steel Primer, Excluding The Cost Of Metal Beading And Other Fittings Except Necessary Hinges Of Pivots Steel Handles And Peg Stay Etc. As Required. 562 Patially Fixed And Partially Openable Fixed Area Not Exceed 33% 563 Supplying And Fixing Fixed Wire Gauge To The Metal Frame Of Rolled Section By Metal Beading 20X3mm With Suitable Screw At Not Exceeding 150 Mm Distance. 564 14 Mesh X 24 Gauge 565 Providing And Fixing 20 Mm Thick Precast Terrazo Tiles Of Approved Make, With Marble Chips Of Size Upto 6Mm Laid Over Roof With Neat Cement Slurry Mixed With Pigment To Match The Shade Of The Tiles, Including Cutting , Grinding Rubbing With Machinecomplete On 20 Mm Thick Bed Of Cement Sand Mortar 1 : 4. 566 Removing White Or Colour Wash By Scrapping And Sand Papering And Preparing The Surface Smooth Including Necessary Repairs To Scratches By Sandal / Loi. ( Only For Colour Changing Only ) . 567 Distempering With Dry Distemper Of Approved Brand And Shade ( Two Or More Coats ) And Of Required Shade On New Work, Over And Including, Priming Coat Of Whiting To Give An Even Shade Including All Scaffolding. 568 Finishing Wall With Water Proofing Cement Paint Of Approved Brand And Manufacture And Or Required Shade To Give An Even Shade Including All Scaffolding: 569 New Work ( Two Or More Coats Applied @ 3.84 Kg / 10 Sqm ) . 570 Old Work ( One Or More Coats ) . 571 Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture Togive An Even Shade : 572 Two Or More Coats On New Work. 573 One Or More Coats On Old Work. 574 Kota Stone Slab Flooring 25 Mm Thick Over 20 Mm ( Average ) Thickbase Laid Over And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab Including Rubbing And Polishing Completewith Base Of Cement Mortar 1 : 4 ( 1 Cement : 4 Coarse Sand ) 575 For Area Of Each Slab Up To 900 Sq. Cm 576 Providing And Laying In Position Cement Concrete Including Curing Compaction Etc. Of Specified Grade Excluding The Cost Of Centering And Shuttering =All Up To Plinth Level 577 M15 Grade Nominal Mix 1: 2: 4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stoneaggregate 20Mm Nominal Size ) . 578 Add 10 % For Water Supply And Sainatry Works 579 Add 10 % For Electric Works 580 Repair Of Boundry Wall At Pmc, Bhaleri, Including Provinf Fixing Of Borbed Wire Fancing Repair Of Gates Et. 581 Earth Work In Excavation By Mechanical Means ( Hydraulic Excavator ) / Manual Means In Foundation Trenches Or Drains ( Not Exceeding 1.5 M In Width Or 10 Sqm On Plan ) Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Taking Out The Excavated Soil And Depositing And Refilling Of Jhiri With Watering & Ramming And Disposal Of Surplus Excavated Soil As Directed With In A Lead Of 50 Meter.All Kinds Of Soils 582 Random Rubble Stone Masonary For Foundation And Plinth In Cement Sand Mortar Above 30 Cm. Thick Wall In : 583 Cement Mortar 1:6 ( 1-Cement:6-Sand ) . 584 Repairs To Plaster Of Thickness 12Mm To 20Mm In Patches Of Area 2.5 Sq. Metres And Under Including Cutting The Patch In Proper Shape, Raking Out Joints And Preparing And Plastering The Surface Of The Walls Complete Including Disposal Of Rubbish To The Dumping Ground Within 50 M Lead : With Cement Mortar 1 :4 ( 1 Cement : 4 Fine Sand ) 585 Repair To Stone Masonary In Cement Sand Mortar 1:6 With Old And New Stone. 586 Cutting Jhiri Above 75Mmx75mm And Below 150X150 Mm Etc. And Making Good. 587 Providing And Laying In Position Cement Concrete Including Curing Compaction Etc. Of Specified Grade Excluding The Cost Of Centering And Shuttering =All Up To Plinth Level 588 M15 Grade Nominal Mix 1: 2: 4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stoneaggregate 20Mm Nominal Size ) . 589 Providing And Laying In Position Specified Grade Ofcement Concrete For Rcc Structural Elements Upto Floor Five Level Including Curing, Compaction, Finishing With Rendering In Cement Sand Mortar 1:3 ( 1 Cement: 3 Coarse Sand ) And Making Good The Joints And Cost Of Plastizers ( If Required ) Excluding The Cost Of Centering, Shuttering And Reinforcementfor Walls ( Any Thickness ) Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc. M20 Grade Nominal Mix / Design Mix 590 Centering & Shuttering With Plywood Or Steel Sheets Including Strutting, Propping Bracing Both Ways With Steel Propsand Removal Of Formwork For Upto Floor Five Level For : 591 Columns, Pillars, Posts And Struts Etc. 592 Providing And Fabricating Reinforcement For R.C.C. Work Including Straightening, Cutting, Bending, Placing In Position And Binding ( Including Cost Of Binding Wire ) All Complete Up To Floor Five Level. 593 Hot Rolled Deformed Bars ( Is : 1139 ) . 594 Plaster On New Surface On Walls In Cement Sand Mortar 1:6 Including Racking Of Joint Etc. Complete Fine Finished: 595 20 Mm Thick. 596 Brick Work With F.P.S. Bricks Of Class Designation 75 In Superstructure Above Plinth Level Upto Floor V Level In All Shapes And Sizes In : 597 Cement Mortar 1:6 ( 1-Cement:6-Coarse Sand ) . 598 Structural Steel Work In Single Section Fixed With Or Without Connecting Plate Including Cutting, Hoisting ( Height Upto 10 M ) , Fixing In Position And Applying A Priming Coat Of Approved Steel Primer All Complete. 599 Providing And Fixing Steel Gate Grating And Grills Made Of Angles, Tees, Square Bars Or Other Flats Black Pipe With Holdfast And Fittings Complete As Per Design And Drawing Including Cutting Welding And Fabrication With Priming Coat Of Red Oxide. 600 Removing White Or Colour Wash By Scrapping And Sand Papering And Preparing The Surface Smooth Including Necessary Repairs To Scratches By Sandal / Loi. ( Only For Colour Changing Only ) . 601 Finishing Wall With Water Proofing Cement Paint Of Approved Brand And Manufacture And Or Required Shade To Give An Even Shade Including All Scaffolding: 602 Old Work ( One Or More Coats ) . 603 Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture Togive An Even Shade : 604 Two Or More Coats On New Work. 605 One Or More Coats On Old Work. 606 Part : E Electrical Works 607 33 Kvring Main Unit Consisting Of 2 Lbs At Incoming & 2 VcbSoutgoing As Per Requirements And Specifications. 608 Stranded Compact Circular Aluminium Conductor, Conductor Screened With Extruded Semi Conducting Compound, Xlpe Insulated, Insulation Screened With Copper Tape, Cores Laid Up, Inner Sheath Of Pe Type, Galvanised Steel Flat Strip Armoured And Overall Pvc Sheathed Cable Confirming To Is 7098 / Ii / 85 With Latest Amendments Of 33 Kv ( Ue ) 609 3Cx300 Mm2 610 Providing & Making Heat Shrinkable Type Indoor / Outdoor / Straight Through Terminations / Joint Kit Of Approved Make Suitable For Xlpe Insulated 33 Kv Cable, With Required Components, Prepration Of Cable Ends, Testing Etc. 611 3 Core 240 / 300 / 400 Sq.Mm 612 Outdoor 613 Indoor 614 Sitc Of Floor Mounted Pmcc ( Indoor, Dust Proff Ip-4X Front Operated With 2 Mm Thick Sheet Metal Compartmentalised ) With All Accessible Parts, Head Shrinkable Sleeves, Smc / Dmc Bus Bar Supports, Padlocking Facility On Outgoing Feeders Etc. 615 Lv Capacitor With Apfc Panel 616 Sitc Of Microprocessor Based Intelligent Power Factor Correction Relay Having Sensitivity Up To 50 Milli Amp Secondary Current And Following Way, Self Analysing Auto C / K Setting According To Targeted Power Factor Setting, The Relay Shall Have Minimum Three Digit Display Unit For Display Of Real Power Factor, Targeted Power Factor, Lag / Lead Capacitor Switching Status, Alarm Output For Under Current, Over Current, Insufficient Compensation, Indication Of Switching On Units, Auto / Manual Status, And 6 To 14 Stage - Sensitivity Upto 50 Milli Amp. 617 Sitc Of Self Healing Mpp / Mp Type Shunt Capacitor ( Banks ) Conforming To Is:13340-41 / Iec :831-1&2 In Existing Panel Or Parallel With Load Terminals , The Capacitor Shall Be Fitted With Discharge Resistors, Pressure Sensitive Disconnector ( Psd ) And Shall Have Dissipation Factor Less Than 0.0025 At 50 Hz And Total Wattage Loss Less Than 0.5 Watt Per Kvar. Including Making Connections With Suitable Capacity Conductors / Cables Testing As Required.Heavy Duty Three Phase 440 V , 50 Hz Capacitor ( Bank ) 618 P / Laying Xlpe Insulated / P.V.C. Sheathed Cable Of 1.1 Kv Grade With Aluminium Conductor Armoured Of Is:7098-I / 1554-1 Approved Make In Ground As Per Is:1255 Including Excavation Of 30Cmx75cm Size Trench, 25 Cm Thick Under Layer Of Sand, Iind Class Bricks Covering, Refilling Earth, Compaction Of Earth, Making Necessary Connection, Testing Etc. As Required Of Size. 619 3 / Cx6 Sq Mm 620 3 / Cx10 Sq Mm 621 3 / Cx16 Sq Mm 622 3 / Cx25 Sq Mm 623 3 / Cx240 Sq Mm 624 Supplying And Making One End Termination With Heavy Duty Double Compression Brass Gland Sibg Type, Aluminium Lugs Duly Crimped With Crimping Tool, Pvc Tape Etc For Following Size Of Armoured Pvc Insulated & Pvc Sheathed / Xlpe Aluminium Conductor Cable Of 1100 Volt Grade As Required Of Size. 625 3 / Cx6 Sq Mm 626 3 / Cx10 Sq Mm 627 3 / Cx16 Sq Mm 628 3 / Cx25 Sq Mm 629 3 / Cx240 Sq Mm 630 Providing & Laying Xlpe / Pvc Pvc Insulated & Pvc Sheathed Armoured Control Cable Of 1.1 Kv Grade With Copper Conductor As Per Is 1275 Including Escavation Of 30Cmx 75 Cm Size Trench 25 Cm Thick Under Layer Of Sand And Lind Class Of Bricks Covering 631 3C X 2.5 Sq.Mm 632 5Cx1.5 Sq Mm 633 14Cx1.5 Sq Mm 634 Supply & Makingone End Termination With Heavy Duty Single Compression Brass Gland Sibg Type, Copper Lugs Duly Crimped With Crimping Tool, Pvc Tape Etc For Following Size Of Arrmoud Pvc Insulated And Pvc Sheated / Xlpe Almunium Cunductor Cable Of 1100 Volt Grad As Required Size. 635 3C X 2.5 Sq.Mm 636 5C X 2.5 Sq.Mm 637 14 C X 2.5 Sq.Mm 638 Supply, Fabricating & Installing Following Sizes Of Perforated Cable Trays Including Horizontal And Vertical Bends, Reducers Tees, Cross Members And Other Accessories As Required And Duly Suspended From The Ceiling With Suspenders And Including Painting As Required. 639 600Mm X 50Mm X 2.0Mm 640 150Mm X 50Mm X 1.6Mm 641 Supply, Installation, Testing And Commissioning Of Copper Wound Transformers 33 / 0.433 Kv, Three Phase, 50 Hz, Dyn 11, Onan Type , Standard Accessories With Off Load Tap Changer ( +5% To -10% In Steps Of 2.5% ) , Winding / Top --- Temperature Rise Of 45°C / 40°Cfirst Fill Oil, Having Permissible Total Loss Values Not Exceeding 7.5% Of The Maximum Total Loss Values For 11 Kv As Per Energy Efficiency Level - 2 At Basic Insulation Level Conferming To Iss 2026 ( Part- I To Part - Ii ) , Latest Ammended And Is 1180 Part-I : 2014. Transformers Described As Above And As Per The Following Continuous Rating 642 400 Kva 643 1250 Kva 644 1600 Kva 645 S.I.T.C. Of Bus Duct Arrangement In Convenient Sections Complete With Enclouser Of Crca Sheet Steel Of Minimum 2 Mm Thickness, Aluminium Bus Bar And Earth Bus For Use On 3 Phase, 4 Wire, 415 Volts, A.C. Supply With Degree Of Protection Ip-42 For The Following Current Carrying Capacity, Including Jointing Of Sections, Copper Flexible Joints. Expansion Joints, Bends, And Earthing With 2 Runs Of Alum. Strips Etc. As Required 646 1 Straight Run With 2 Earth Bus 3200 Amp 647 Bend 3200 Amp 648 Copper Flexible Tpn 3200 Amp 649 Supply Installation Testing & Commissioning Of Local Push Button Stations 650 Maintenance Free Gel Earthing With Pipe In Pipe / Strip In Pipe Technology Filled With Anti Corrosive Conductive Compound ( Cpri Tested ) Below The Ground In 150 -200 Mm Dia Earth Pit And Surrounding Filled With Required Mineral Filling Compound ( Mfc Should Have Hygroscopic Proper Ty To Retain The Moisture For Long Time To Create Low Resistance Zone ) And C.C. Finished Chamber Covered With Hinge Type With Locking Arrangement C.I Cover. C.I. Frame Of Size 300Mm X300mm Complete Testing Of Earth Resistance As Required Of Following Sizes With Pipe In Pipe Technology ( Inner Pipe Dia / Outer Pipe Dia ) 80 -100 Micron G.I. Coating Of The Size G.I. Pipe 3000 Mm Long , 80 / 40 Mm , Terminal 14 Mm G.I. Strip 651 S & Laying Following Size Earth Wire / Strip In Horizontal Or Vertical Run In Ground / Surface / Recess Including Riveting, Soldering, Saddles, Making Connection Etc. As Required. 652 50Mm X 6Mm G.I. Strip 653 25Mm X 6Mm G.I. Strip 654 25Mm X 3Mm G.I. Strip 655 10 Swg G.I. Wire 656 P & F Lightning Conductor Final Made Out Of 25 Mm Dia., 300 Mm Long Copper Tube Having Single Prong At Top With 85 Mm Dia., 3 Mm Thick Copper Base Plate Including Holes Etc. Complete As Required. 657 Part : F Instrumentation & Scada 658 Sitc Of Ultrasonic Level Transmitter Suitable For Measuring Water Level In Reservoir, Normal Powered 24Vdc, Type Of Transmitter: Two Wire ( 4-20 Ma ) , Cable Entry:1 / 2 Npt ( F ) , Sensor Material: Pp, Slip-On Flange: 2 ½” Flange, Material Of Construction For Slip-On Flange: Pp, Output 4~20Ma, Hart Compatible, Accuracy + / _ 0.2 % As Per Detailed Technical Specification, Scope Of Work And Direction Of Engineer In Charge. Measuring Range 0.0 To 6.0 Mtr 659 Providing, Installation, Testing And Commissioning Of Diaphragm Type Pressure Gauges Dial Size 150 Mm Glycerin Filled Shatterproof Glass, Over Range Protection: 125% Of Maximum Pressure, Material Of Sensor And Other Wetted Parts: Ss Type 316, Housing Material: Die Cast Aluminum 660 Providing, Installation, Testing And Commissioning Of Pressure Transmitter For Water Application: Range: 0-10 Bar / Power Supply: 24 V Dc / Output: 4-20 Ma With Hart / Diaphragm: Ss316l / Process Connection: 1 / 2 Npt ( M ) / Accuracy: 0.15% Protection: Ip671 / 2 M ( Npt ) 661 Sitc Of D / F Full Bore Type Electromagnetic Flow Meter Of Approved Make Of Following Dia And Specifications Complete: Media : Water ( Raw / Chlorinated ) , Pressure : Up To 1.5Mpa, Process Temp: - 50 Deg C, Flow / Meter Tube : Ss 304, Electrode : Ss Aisi 316L / Hastelloy C276 / Tantalum, Lining Material : Hard Rubber / Neoprene / Poly-Urethane ( Pu ) , Flange : Ss / Cs, Flange Standard & Rating : Ansi 150, Coil Housing : Ss Aisi 304 / Carbon Steel / Die Cast Aluminium, With Anticorrosive Paint & Provide Completely Sealed ( Leak Proof ) Construction As Per Requirement Of Iec 60529, Accuracy : ± 0.5 % M.V.- Velocity 0.3 To 10 M / S, Transmitter / Signal Convertor Enclosure : Die Cast Aluminium, Power Supply : 80-240 V Ac - 50Hz, Output 1 : 4-20 Ma, Output 2: Pulse, Communication Output : Rs 485 / Heart, Display Type : Lcd / Led Display, Cable Entry : M20 X 1.5, Provision Of Ram / Prom To Store Calibration And Configuration Parametersand Totalizer Value During Power Failure, Protection Category- Ip 68 For Sensor ( Flow Tube ) And Ip 67 For Transmitter / Convertor, Including Surge Arrester, If Required, And All Materials Required For Making Connection With Existing Pipeline Including Cutting The Existing Pipeline Etc. Complete In All Respect As Per Technical Specification And As Per Direction Of Engineer In-Charge.Note: Rates Are Exclusive Of Tail Piece / Dismantling Joints And Earth Work. 662 150 Mm Dia 663 200 Mm Dia 664 250 Mm Dia 665 400 Mm Dia 666 900 Mm Dia 667 Sitc Of Bulk Flow Meter With Removable Mechanism Class B Confirming To Iso:4064:2005 / Is: 2373Of Approved Make Of Following Dia Sized Pipelines And Specifications Complete:Media : Water ( Clear ) , Temp. 50 Deg., Pr. Rating: Pn16, Protection Type: Ip- 68, Body Material : Is-210 Gr. Fg-200, Accuracy Class :Class B ( ±2 % @ Nominal Flow Rate ) , Magnetic Drive, Dry Dial, Epoxy Powder Coated, Pulse Out Put Option, Anti-Magnetic Protection Including All Materials And Making Connection With Existing Pipeline Required For Bulk Flow Meter Including Cutting The Existing Pipeline Etc. Complete In All Respect As Per Technical Specification And As Per Direction Of Engineer In-Charge.Note: Rates Are Exclusive Of Tail Piece / Dismantling Joints And Earth Work. 668 Bfm 100 Mm 669 Bfm 150 Mm 670 Bfm 250 Mm 671 Sitc Of Rtu Complete With Di, Do, Ai And Modbus Communication Ports And Power Supply ( 24 V, Dc ) 672 Providing And Laying Stranded / Flexible Annealed Bare Copper Conductor , Xlpe / Pvc Insulated 2 Pair 1.5 Sqmm Suitably Laid Up Together Overall Polyester Taped Al ( Mylar Tape Wrapped ) Along With Atc Drain Wire Overall Pvc Sheathed ( St-1 ) Overall Screened Triad Armoured Instrumentation Cables Generally Confirming To Pas 5308- Part-2-2009 673 Providing & Laying Xlpe / Pvc Pvc Insulated & Pvc Sheathed Armoured Control Cable Of 1.1 Kv Grade With Copper Conductor As Per Is 1275 Including Escavation Of 30Cmx 75 Cm Size Trench 25 Cm Thick Under Layer Of Sand And Lind Class Of Bricks Coveringsize 3C X 2.5 Sq.Mm 674 Supply, Installation, Testing And Commissioning Of Mnre Approved Off Grid Solar Panels For Running Of Motor Pumps With 25 Years Of Linear Generation Warranty, Work Includes Designing Of Solar Panel Area And Ms Frame And Foundation On Ground / Roof Of Pump House Or Cwr, Showing Arrangement Of Panel In Available Space, Installation Of Pv Module On Ms Frame As Per Approved Design And Drawings. Mounting Structure Shall Be Suitably Design To Withstand Wind Velocity Up To 150Km / Hr. The Work Shall Be Executed As Per Detailed Technical Specifications, Approved Drawing And Direction Of Engineer In Charge. Note: There Shallbe5 Year Service Warranty For Solar Panel And Mounting Structure Andsuitable Provision Shall Be Included In Tender Document ( Each Of .5 Kw ) 675 P&F Of Gsm / Gprs Based Data Transmitter Device Forwater Meter Compitable To Scada System. 676 Supply, Installation, Testing, Commissioning Of Plc / Scadasystem Including All Hardwares, Softwares, All Accessorings For Thefollowingpump Houses As Per System Configuration Alongwith Scada For Master Control Centre For Monitering The Water Supply. As Per Scope And Specificationscomplete In All Respect. Ans As Per Direction Of Eic At The Following Locations. 677 Cps Bhalari 678 Supply, Installation, Testing, Commissioning Of Master Control Room Including All Plc / Scadasystem, Hardwares, Softwares, All Accessorings For Thefollowingpump Houses As Per System Configuration Alongwith Scada For Master Control Centre For Monitering The Water Supply. As Per Scope And Specificationscomplete In All Respect. Ans As Per Direction Of Eic At The Following Locations.Churu 679 Part G : Operation & Maintainance & 680 Cost Of Operation And Maintenance Of The System For 10 Years After Defect Liability Period Of One Year @ 6.0%On Above Items Excluding Villages Inrta Systemand As Per Scope Of Work & Specification 681 Operation And Maintenance Charges 1St Year 682 Operation And Maintenance Charges 2Nd Year 683 Operation And Maintenance Charges 3Rd Year 684 Operation And Maintenance Charges 4Th Year 685 Operation And Maintenance Charges 5Th Year 686 Operation And Maintenance Charges 6Th Year 687 Operation And Maintenance Charges 7Th Year 688 Operation And Maintenance Charges 8Th Year 689 Operation And Maintenance Charges 9Th Year 690 Operation And Maintenance Charges 10 Th Year 691 Part H : Dismantling Of Old Pump Sets 692 Cost For Dismantling Of Old Pump Sets, Electrical Panels And Intrumentation Etc And Depositing In Depatmental Stores As Per Direction Of E.I.C. 693 Tps Karamsana 694 Ir-4 695 Cps / Tps Bhaleri 696 Cps / Tps Churu
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
35.
Housing Urban and Rular Development #10235078 Price Bid
Tender For New Construction Of Cheriyan Nagar Library Chennai; 1 DISMANTALING WORKS 2 Dismantling etc., all complete 3 Brick / Stone Masonry in lime mortar walls 4 Dismantling RCC by manual / by using deploying machineries 5 Doors and Windows including removal of frames, hinges and fastenings 6 CIVIL WORK 7 Earth work excavation for foundation in Hard stiff clay, stiff black cotton, hard red earth, shales murram, gravel,stoney earth and earth mixed with small size bouldersand Sand, silt or other loose soil, wet sand,or silt not under water, light black cotton soil, sandy loam ordinary soil and to full depth as may be directed except in hardrockrequiring blasting inclusive of shoring shuttering and baling out water and cleaning and levelling the site etc.,complete SS.20B 10 cum 8 Carting away surplus excavated earth available with in the campus is to be carted to a lead of within 40 KM from site. The rate shall include loading into the tipper/ lorry transporting and unloading, leveling and the earth scooped by bulldozers grading etc.,complete with all respects complying with relevant standard specification, as directed by the Departmental Officers. Rate to include materials, loading, unloading, transportation, plant and machinery, hire and fuel charges for tools and plants and other incidental charges, royalties, seignorage and taking statutory approvals as necessary to carry out the work as complete with all respects complying with relevant standard specification, as directed by the Engineer-in-charge. 9 Supplying and filling in foundation andbasement with Crushed Stone Sand (M- Sand) in layers of not more than 15cm thick well rammed watered and compacted etc., complete complying with standard specification. 10 Supplying and filling in foundation, basement, etc with filling Gravel inwellrammed and consolidated etc. complete complying with standard specification and as directed by the departmental officers. 11 Plain Cement Concrete 1:4:8 (one part of cement, four part of Crushed Stone Sand (M- Sand) and eight part of coarse aggregates) using 40mm size ISS HBG metal including cost and conveyance of all materials to site and including for the mixing, laying and labour charges and all incidential charges such as water providing etc., complete as per standard specification 12 Providing pre-constructional Antitermite treatment including cost of chemicals labour as per standard specifications for preparing the area for treatment by spraying chemicals and other incidental charges etc.. complete. The rates should be for antitermite treatment from the plinth beam and brick masonry with super structure in contact with the back fill earth and at the junction of the walls.The top surface of filled earth for flooring and the soil along with the perimeter of the building by making holes with the crow bar and poured 5% termicide “Chloripyrifos” and sprayingthe same termicide solution on the wooden frames and treating the other periphery of buildings etc., complete in all respects as per IS 6313 (part II) / 1981 and as directed by the departmental officers. 13 Supplying and erecting centering for sides and soffits including supports and strutting up to 3.30 m height with all cross bracing for plane surfaces as detailed below, using mild steel sheets of 90 X 60 cm 10 gauge stiffened with MS angle of 25 X 25 X 3mm for boarding, laid over adjustable span & jacks and supported by 50mm dia pipes for general pipes scaffolding systems @ a spacing of 1.20m c/c and vertical connected at a height of 2.0m c/c including C & U clamps and base receiver cup at bottom for connecting pipes etc and removable systems etc.,Rate to include all materials, labour charges, wastages ,placing, transportation, lead & lifts, tools & plants, fuels, fixing in position at all levels, heights, masking tape in sheet joints, consumables, etc. as complete with all respects complying with relevant standard specification, as directed by theClient / Engineer-in-charge. 14 For Column footing, plinth / grade beam, bed blocks, template surfaces, steps, piers, raft slab / beams and such other members 15 for plane surfaces such as rectangular or square rcc columns, sunshades, topand bottom slab of rcc boxing, etc. 16 Plane surfaces such as RCC floor slab, roof slab, beams, lintels, bed blocks, landing slab, waist slab, portico slab / beams and such other members 17 Providing and Laying M 30 Design Mix for all reinforced cement concrete with minimum cement content conform to IS 456-2000 using ordinary Portland cement of grade 53 from approved manufacturer, manufactured sand, 20 mm and down graded size coarse aggregates, necessary approved admixtures as per requirement. works for Raft, Grade beam, Shear wall, RCC walls, Lift walls, Plinth beams, Column, footings, Grade slab, Roof slab & beam, Curved slab, beam, Column drops, Pergola, Staircase waist and landing slab lintel, Sunshades, parapet Cum drops, Steps, canopy, window boxing slab, Loft, fins facia Planter box binders basement retaining wall, machine foundation, elevation features and other similar structures etc..excluding necessary centering, shuttering and reinforcement which shall be measured and paid separately under relevant items. 18 For FoundationandBasement 19 For Ground Floor 20 For First Floor 21 For Second Floor 22 Supplying, fabricating and fixing in position of steelFe 550 grade Reinforcement for all RCC work with Thermo Mechanically Treated Bars (TMT) conforming to IS 1786 of latest version according to drawings and binding the reinforcement with 18 gauge double fold GI binding wire and providing Concrete / PVC cover blocks to maintain the cover as required.Rate to include all bending, tying grills, placing, transportation, lead & lifts, tools & plants, fuels, all materials, labour charges, wastages , laying at all levels, fixing in position, cost of cover blocks, etc. as complete with all respects complying with relevant standard specification, as directed by the Engineer-in-charge. 23 Supply and constructing Fly ash Brick (230 x 110 x 75mm) masonry in Cement Mortar 1:5 (One cement and Five M sand) in foundations, basement and superstructure usingFly ash Bricks of size 230x110x75mm etc. Rate to include all materials, labour charges, wastagesfor working at all levels with necessary lead and lifts, transportation charges, loading, unloading, scaffolding, staging, curing, fuel, consumables as complete with all respects complying with relevant standard specification and as directed by theClient / Engineer-in-charge. 24 For Ground Floor 25 For First Floor 26 For Second Floor 27 Providing two legged scaffolding using 15 cm dia casuarinas post of 4 M over all length (3 M Height + 0.5 M Projection + 0.5 M into the Ground) the distance between the two rows being 1.25 M and the spacing of posts being 2.0 M in both the rows with two horizontal posts with 0.5 M. Overlap on either side and braces at 2.0 M Center to center including longitudinal and transverse middle braces to step up and providing a platform with country wood planks of 40 mm thick and 1 M width, etc. in a complete from using coil and nails. 28 Upto 3 M Height 29 3 m to 5.5 m Height 30 5.5 m to 7.5 m Height 31 7.5 m to 10 m Height 32 10 m to 12.5 m Height 33 Plastering 10 mm thick for ceiling including slabs, beams and column drops and staircase waist slab, sunshade, drops, chajjas etc..with Cement Mortar 1:3 (1 of cement : 3 of P sand) according to the specification. The rate including cost of all materials, labour charges, wastages, necessary lead and lifts, working at all levels, transportaion charges, loading, unloading, preparation of surface, ncessary haccking in RCC surface, scaffolding, stagging, providing drip bands, moulds to any size and shape as shown in drawings tools and plants, fuel, curing,cleaning, consumables etc as complete with all respects complying with relevant standard specification and as directed by the Engineer-in-charge. 34 Plastering 15 mm thick for external surfaces with Cement Mortar 1:5 (1 of cement : 5 of P sand) with water proofing compound of “CICO No.1 or equivalent“ as per Manufacturers Specification with sponge finish (washed sand finish) all complete as per specification and as directed. The rate includingcost of all materials, labour charges, wastages, necessary lead and lifts, working at all levels, transportaion charges, loading, unloading, preparation of surface, ncessary haccking in RCC surface, scaffolding, stagging, providing drip bands, moulds, grooves to any size and shape as shown in drawings tools and plants, fuel, curing,cleaning, consumables etc as complete with all respects complying with relevant standard specification and as directed by the Engineer-in-charge. 35 Plastering of 12 mm thick for Internal walls with cement mortar 1:5 (1 of cement : 5 of fine river sand)according to specifications. Rate shall include for providing GI chicken mesh of nominal thickness at the junctions of masonry and concrete works to a width of 100 to 125mm including tying in position with suitable clamps/screws. Rate including all materials, labour charges, wastages with necessary lead and lifts, working at all levels, transportation charges, loading, unloading, preparation of surface, necessary hacking in RCC surface, scaffolding, stagging, tools and plants, fuel, curing,cleaning, consumables etc as complete with all respects complying with relevant standard specification and as directed by the Engineer-in-charge. 36 Painting the new plastered walls with two coats for Interior Plastic Emulsion paint approved quality and colour over a priming coat, with two coats of wall putty including thorough scrapping, clean removal of dirt, etc complete and including necessary plaster of paris, putty, wherever required etc, complete as per standard specification. 37 Painting two coats for Exterior surface with approved Exterior Plastic Emulsion paint approved quality and colour over a priming coat, including thorough scrapping, clean removal of dirt, etc complete and including necessary plaster of paris, putty, wherever required etc, complete as per standard specification. 38 UPVC Window Specification:Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Windows of casement type (open) from the profile the size of outer frame 60mm x 58mm and shutter profile are reinforcement with GI/1mm 125GSM and 100% corrosion free, the profiles are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with over all the edges of frame and shutter the shutter will be provided with Espag multi power point locks and also it operates as handle. The corners and joints should be welded and cleaned. Radiations free pin headed plain or brown colour glass 4mm thick should be provided to the shutter and it should not allow leakage of water even at most ranging storms and should have key lockable action, security protective hinges, strong locking systems and as per size for arresting noise and energy loss. The connecting mechanism between sash and outer frame that enables opening of the window. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The window should be got approved from the Executive Engineer before use on work 39 UPVC VentilatorSpecification: Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Louvered Ventilators of from the profilethe size of outer frame 60mm x 58mm and shutter profile size of 60 x 78mm both profiles arereinforcedwith GI/1mm 125GSM and 100% corrosion free, the profile are multi chamberedsections with wall thick of2mm.The EPDM rubber (black colour) covered with all over the edges of frame and shutter.The corners and joints should be welded and cleaned.Radiations pin headed glass 4mm thick should be provided in the louvers.The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames.The ventilator should be got approved from the Executive Engineer before use on work 40 Supply and fixing of M.S Grills with Doors and Windows with one coat of Red oxide with Primer including all costs such as welding,grinding and fabrication charges, cost and conveyance of all materials to site etc,complete as per standard specification. 41 Painting the new Iron work with two coats of Ready Mixed Enamel Paint of aproved quality and colour over the existing priming coatincluding the cost all materials etc.,complete, in all floors and as directed by the Departmntal Officers. 42 Providing and fixing Vertical blinds , quality of approved make fabric made of 100% polyester woven fabric thickness 0.40mm with virtually maintenance free having plastic bottom chain thickness of chain-0.50mm and diameter-3mm, Plastic with metal bottom and suitable coating on exterior, including all fixtures and fittings complete in all respect as per design/color/shade including requisite installation brackets etc as required for installation at site with anchoring arrangements complete. 43 Supply and laying with best quality the following materials of Ruby Red, Raw Silk Granite Slabs (Super Fine Polished with Machine Cut Edges) of sizes 4’x2’ and above 18mm to 20mm thick Thick including cuttingand edge polishing to be set in CM 1:3 (1 of cement : 3 of manufactured sand) 20 mm thick including finishing the joints with white cement slurry, cutting, edge chamfering to approved shape and polishing rough, medium, nice and tin-oxide polish.Rate including all materials, labour charges, wastages, necessary lead and lifts, working at all levels, transportaion charges, loading, unloading, preparation of surface, ncessary haccking in RCC surface, cutting to required shape, edging, tools and plants, fuel, curing,cleaning, acid wash over finished surface, protection with Gypsum / Poplayeroverplastic sheet and removing the same before handing over as complete with all respects complying with relevant standard specification and as directed by the Engineer-in-charge. 44 Supply and laying with best quality the following materials of Sinthetic Grey, Paradise and similar varieties Granite Slabs Granite Tiles - (Superfine Polished with Machine Cut Edges) of size 2’0” x 1’0” and above 10mm Thick including cuttingand edge polishing to be set in CM 1:3 (1 of cement : 3 of manufactured sand) 20 mm thick including finishing the joints with white cement slurry, cutting, edge chamfering to approved shape and polishing rough, medium, nice and tin-oxide polish.Rate including all materials, labour charges, wastages, necessary lead and lifts, working at all levels, transportaion charges, loading, unloading, preparation of surface, ncessary haccking in RCC surface, cutting to required shape, edging, tools and plants, fuel, curing,cleaning, acid wash over finished surface, protection with Gypsum / Poplayeroverplastic sheet and removing the same before handing over as complete with all respects complying with relevant standard specification and as directed by the Engineer-in-charge. 45 Nosing for Granite Slab-Single Nosing 46 Grooving the Granite Slab 47 Paving the floor with Double charged Vitrified tiles of approved quality and colour of size 600x600x8mm thick of approved make, quality and colour in all floors over a base layer of cement mortar 1:3 (One part of Cement and Three part of Plastering Sand (P- Sand)), 20mm thick and laid straight alignment and pointed neatly with colour cement at the rate of 0.40kg/m2 laid without any air gap in the tiles neatly and fixing in position as per standard specifications and as directed by the departmental officer.The colour & quality of tiles should be got approved by Executive Engineer before use on work 48 Paving the floor with design Antiskirt Ceramic tiles (colour and shade as directed) of size 305 mm x 305 mm x 6 mm in all floors over a base layer of cement mortar 1:3 (One part of Cement and Three part of Plastering Sand (P- Sand)), 20mm thick laid in-situ and pointed with same coloured cement. 49 Supplying and fixing Dadooing the wall with ceramic tiles of approved quality, colour and design joint free of size 600x300x10mm thick of approved make, in all floors over a base layer of cement mortar 1:2 (one cement: Two sand) 10mm thick and laid straight alignment and pointed neatly with colour cement at the rate of 0.40 kg/m2 laid without any air gap in the tiles neatly and fixing in position as per standard specifications. The rate including cost of all materials, labour charges, wastages, necessary lead and lifts, working at all levels, transportaion charges, loading, unloading,the same before handing over as complete with all respects complying with relevant standard specification and as directed by the Engineer-in-charge. 50 Supplying and filling the sunken slab area by BRICK-BATCOBA by adding CICO NO:1 of approved equivalent admixture including applying two coats not less than 2 mm thick of TAPECRETE- Acrylic Polymer Based Naterproof Coating, over the final coat of cement plaster 12 mm thick with cement sand mortar 1:3 mixed with water proofing compound like CICO No.1 at the rate specified in the manufacturers specification after entire completion of laying pipes, sanitary fittings etc Rate including all mater aaod and lifts, working materials, labour charges wastages with necessary lead and at all levels, protecting the laid pipes and sanitary fittings, finishing the surface smooth to receive the top coat of water proofing application etc. as complete with all respects complying with relevant standard specificatior and as directed by the Client/ Engineer-in Charge 51 Including applying two coats not less than 2 nm thick of TAPECRETE- Acrylic Polymer Based Waterproof Coating, over the plastered surface as including final coat of cement plaster 12 mm thick with cement sand mortar 1:3 mixed with approved water proofing compound like CICO No. 1 or approved equivalent conforming to IS 2645 at the rate specified by the manufacturer over coated surfacepreparation of surface, finishing, curing etc. all complete at all levels as per manufacturers specifications and as directed. 52 Waterproofing: Providing and Applying CFTRI approvedtwo component flexible polymer modified acryliccementitious waterproofing coating with a mix ratio of(5 Liquid :7 Powder) to the RCC surface of the UGT/OHT tankapplied @ 2.2kg/m2 in 2 coats to achieve1.2mm DFT, having Elongation at break >120% asper ASTM D 412, Tensile strength >1N/ mm2 as per ASTM D 412, Adhesion strength: 0.80N/mm2 as per ASTM D 4541, crack bridging upto 2mm as per ASTM C 836. The finished cost to include surface preparation, making coving of 50 mm X 50mm at all right anglesof wall Junction with Polymer Repair Mortar and lay 45 gsm glass fibre mesh over the angle fillet when the first coat in still wet, treatment of cracks completelyas per specification. Followed by applying 15 mm thick dimensionally stable fibrous reinforced cementitious structural grade dual shrinkage Polymer Mortar on as protective plastering @ 29kg/m2. The material having Compressive strength of 38 MPa at 28 days as per EN 12190, Adhesive Bond Test, >1.5 Mpa as per EN1542, followed by Water curing by sprinkling water for 3 times a day for 5- 7 days. Followed by applyingtwo component, water-based food grade epoxy resin coating on inside surface of Potable water tank having anti algae, antifungal, Non-toxic, hygiene cum damp-proof coating Certified by CFTRI as per 21 CFR 175 – 300 of US – FDA, having mixing Ratio (Base: Hardener: Water) – 1:1:1 to be applied @ 0.35 Kg/m2 in 2 coats. Ensure that this coating is applied over the protective plaster. The Waterproofing material shall have Specific Gravity: 1.2, Water vapor permeance: 244.48 g/m2/24 hrs, as per IS 7809/Pt 2/1977, Adhesion strength: 2 N/mm2 as per ASTM D 4541: 02. The finished cost to include surface preparation completely as per specification 53 Finishing the top of roof with one course of Solar Reflective ceramic tiles of size 305 mm x 305 mm x 7 mm of approved quality in Cement Mortar 1:3 (One part of Cement and Three part of Plastering Sand (P- Sand)), 12 mm thick mixed with water proofing compound conforming to ISS at 2% by weight of cement used and the joints pointed neatly to full depth of tiles with the same cement mortar mixed with red oxide and water proofing compound including curing etc., complete 54 Supplying And Fixing Rubber Moulded Interlocking Paver Blocks Against Available Edge Restraints 83 mm Thick of Approved Design And Pattern of Strength 40 N/Sq.m. 10 mm Iss Metal With Minimum Cement Content As Applicable To M 40 Grade Concrete As Per Is-456-2000 Manufactures By Mechanical Or Hydraulic Machine Using Vibro- Compaction Process And Laid Over 50 mm Thick Laying Course (Bedding) Crushed Stone Sand (M Sand) Well Compacted By Plate Compactor With A Joint Width of 2 mm To 5 mm Including Filling of All Joints With Crushed Stone Sand (M Sand) And Compacting The Paved Surface With Plate Compactor Two Or Three Times Until All The Unit-To- Unit Joints Are Completely Filled With Crushed Stone Sand (M Sand) And Trimming The Edges Neatly Including All Labour Charges And Plate Compactor Charges Etc. Complete(Cost Inclusive of Crushed Stone Sand (M Sand)) 55 Supplying and fabricating of MS structural steel supports for various applications using channels, MS angle iron, bolts, nuts, anchor bolts etc., required for the work, cut to the size, bent to shape, welding, grouting etc., complete. Supports shall be powder coated with required colour for different system as mentioned above. 56 Providing Teak wood wrought and put up for frames of doors, windows and ventilators and any other similar joinery works including cost of country wood scantlings and labour charges for manufacturing the frames and fixing hold fasts and fixing in position etc. for all lengths as per architect designs. 57 Best Indian Teak Wood Panelled door in double shutters with frames 100x75mm at side,verticals and top. The shutters shall beof 40mm thick with moulded panels in 20mm thick planks,6Nos.of iron hold fasts fixed in c.c.1:2:4 6Nos.of butt hinges 125mm long including wind appliances, furniture,iron fittings,1No.of iron padlock 15cm long for locking arrangements and fixing inposition,etc.,complete.(ISI STD) 58 Varnishing the new wood work one coat with best shellac and with fine best varnish of approved quality varnish of teak wood natural finish including preparation of surfaces with sand papering in patty priming etc., complete complying with standard specification and as directed by the Departmental officers. 59 Solid PVC Door Shutters using 19 Gauge 19mm MS square tubes for styles and outer frames. 15mm MS square tubes for top, lock and bottom rails. The steel tubes shall be covered with 5mm thick solid PVC Sheets. Shutter using 5mm thick solid PVC Sheets for panelling shall rigidly fixed in position including necessary furniture and fittings. The over all size of styles shall be 50mm x 30mm. The over all size of top rail, lock rail and bottom rail shall be 75mm x 30mm. The over all size of frames shall be 50mm x 45mm with suitable rabate for housing the shutter 60 Best Indian Teak Wood panelled door shutter for single leaf door. The shutter shall be 40mm thick with moulded panels in 20mm thick planks inclusive of 3 Nos.butt hinges 125mm long,furniture iron fittings,1No.of jappened hooks and eyes 200mm long and 6mm thick and iron pad lock 15cm long including fixing inposition,etc.,complete 61 FALSE CEILING WITH GYPSUM PLAIN TILES Providing and fixing true horizontal level false ceiling using SAINT -GOBAINGYPROC or Equivalent make with 24 mm Grid system using hot dipped galvanised Steel Section, exposed surface chemically cleaned caping prefinished in backed polyestar paint wall angle of size 24mmX24mm used in the periphery of the ceiling fixed to the wall partition R.C. Column bandwalls with the help of screws Column bandwalls with the help of screws at 600mmc/c. Main runner of size 32X24mm suspended at1200mm c/cmax by using securely fixed to the structural soffit of R.C.C. slab by using 6mm Nylon Rawl plug at every 1200mm (Max) and 1200mm long Cross Tee of size 24X24mm to interlocked between Mainrunner at 600mm c/c (max) to form a grid of 1200mmX600mm. 600mm long Cross Tee of size 24X24mm is inserted to form a grid of 600mmX600mm and finally tiles laying 62 Art work as per the direction of department official, over Oil Painting with first class quality and approved colour including a priming coat with thorough scrapping clean removal of dirt., etc., complete and including necessary plaster of paris, putty, etc., wherever required (Relevent ISI STD), including putty works. 63 Supplying and Fixing of English Stainless Steel Letters of 25cm (10”)size and approved colour. The colour treatment process is achieved with MRF colour coat and then the processed coloured layer is set into the kiln for the heat treatment process for the following sizes 64 Supplying and Fixing of Tamil Stainless Steel Letters of 25cm (10”)size and approved colour. The colour treatment process is achieved with MRF colour coat and then the processed coloured layer is set into the kiln for the heat treatment process for the following sizes 65 upplying and Fixing ofEmblem (15”) Stainless Steel size and approved colour. The colour treatment process is achieved with MRF colour coat and then the processed coloured layer is set into the kiln for the heat treatment process for the following sizes 66 Supply and fixing of Pre-fabricated Structural Steel, coated galvalume ROOFING SHEET of 0.5mm thickness with SMP coating with colour bond XRW coating, having minimum of 550 Mpa yield strength, Coating 150 GSM as per ASTM 792 or equivalent standard. The structural roofing Panel shall have 1020 mm effective width, nominal 30 mm crest height at nominal 250 mm centre to centre pitch with the embossment (share grove) on top & side of ribs for better composite action including Flashing for joints, and all incidental charges. 67 Supplying and erecting in position LIGHT DUTYSTEEL TRUSSES as per the drawing.The materials and design of the trusses should confirm to the relevant Indian Standard specification.The trusses shall be procured only from reputed manufactures oftrusses with prior approval of the Buildings Engineer and a certificate to the effect from the reputed manufacturers shall also be furnished with design.The rate quoted shall include the cost oftrusses.Base-plate with holding down bolts and nuts to RCC or Masonry works, roof purlins, rafters, purlin sleeves, the members fixing accessories etc., painting one coat of red-oxide paint and erecting in position etc., complete as directed during execution. The contractor shall also arrange to provide grouting for holding down bolts embeding the end purlins, to the gable wall wherever necessary etc.,The roof sheeting shall project 0.762m from the eves purlins. 68 Providing Wall Panelling using one side teak wood sheet with melamine polishing with following specification. The frame using aluminium tubular section of size 50mm x 25mm x 2mm thick fixing horizontally and vertically in position with wall at interval of 0.60m in both diretions, fixing water proof plywood of 12mm thick over the aluminium frame work with necessary screws. One side teak wood sheet of 3.5mm thick will be fixed over the plywood using fevical and finishing with melamine polishing and the rate inclusive of conveyance to site and labour charges and as directed by the Departmental Officers. The design pattern, water proof plywood, OST sheet and other materials to be used shall be got approved by the Executive Engineer concerned before use on work etc., complete. 69 Providing, supplying, and fixing factory-manufactured pre-fabricated insulated roofing panels made of PUF (Polyurethane Foam) sandwiched between two metal skins, comprising pre-painted galvanized iron (PPGI) sheets of 0.5 mm thickness on both sides with 40 mm to 50 mm thick CFC-free polyurethane foam core of minimum density 40 kg/m³, having tongue and groove jointing with cam-locking arrangement for weather-tight sealing. Panels shall have minimum overall R-value of 6.5 and thermal conductivity not more than 0.022 W/m·K. Roofing to be supported over structural purlins/trusses using self-drilling screws with EPDM washers, sealants, fasteners, ridge covers, and flashing, complete. Rate includes supply, transport, hoisting, cutting to size, edge finishing, foam taping at joints, sealing, labour, tools, scaffolding, and all incidentals for a fully finished, insulated, and weatherproof roofing system as per manufacturer’s specification and as directed by the Engineer-in-Charge. 70 Brick Wall Cladding Nuvocotto Edge Cut Wall Tiles Natural Red finish in size 230mm x 76mm x 15mm 71 Brick JalliNuvocotto Camp Jallie Natural Red finish in size 200mm x 200mm x 60mm 72 Supply and fixing of stored pressure ABC (Mono Ammonium Phospate) Powder Type Fire Extinguisher of 6 kg. capacity as per IS:15683 with pressure gauge, discharge hose & control nozzle, wall mounting bracket, safety clip etc., including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary etc, complete as per standard specification and as directed by the Departmental Officers. Make: EXCELLENT / SAFETY FIRST / EQUIVALENT 73 Supplying of plastic Potted plants Anthurium size of dia 12 inch including loading and unloading charges, transportation, etc as directed by the site in-charge 74 Supplying of plastic Potted plants Bogainvillea size of dia 12 inch including loading and unloading charges, transportation, etc as directed by the site in-charge 75 Supplying of plastic Potted plants Ficus ponda size of dia 12 inch including loading and unloading charges, transportation, etc as directed by the site in-charge 76 Providing & laying spreading & Compacting graded stone aggeragate of size 45mm to 22.4mm, 22.4mm to 2.36mm & 2.36mm to 75 microns to Wet Mix Macadam (WMM) specification including premixing the material with water at OMC in Mechanical mix plant carriage of mixed material by tipper to site, laying in uniform layers with paver in Sub base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density, rate including the cost & conveyence of all materials, labour charges for spreading, watering, rammed & consolidation and other tools & plants employed for the work etc., all complete and as directed by the departmental officers as per MORTH specification 406 IV Revision 77 Supplying and filling with M-Sand well watered rammed, and consolidated complying with relevant standard specifications etc., complete and as directed by the departmental officers. 78 ProvidingandlayingofBlackGraniteCobbleStoneflooringof approvedmake,inallcoloursandshades,laidon20mmthick cementmortar1:4(1cement:4coarsesand),jointingwithgrey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc., complete. 79 SupplyingandlayingGrassPaverblock M40grade Providingand layingof 63mm thickhighstrengthtypeconformingIS15658- 2006ofrubberizedinterlockingpaverlockinsizeofminimum compressivestrengthof40N/mm2inuniformshapeofapproved maketobelaidinflurringbonepatternwithsandcushionbelow theuniformshapofapproved nonskittingsurfaceinthetopand therateincludinglevellingthebasepreparationof paversassub base,sandcushion150mmthicklaying outofpavementcutthe piecestofixtheedgevibringthepavers,sweepingtranporting loadingunloadingoflayingpaverblockasperstandard specification,. 80 PLUMBING 81 Supplying and fixing in position White / Colour Glazed Model Floor Mounted European Water Closet of best quality and approved make with 100mm “P” or “S” trap connecting with CI pipe of 100mm dia / PVC pipe of 110mm dia, double flapped rigid PVC black seat and seat cover with CP brass hinges including cost of white cement, cement for packing, spun yarn, teak wood plugs, brass screws, etc., including supplying and fixing 10 litres capacity PVC / 12.5 litres capacity porcelin low level flushing tank with a pair of CI brackets, etc., complete with all fittings, such as, 15mm brass ball valve with polythene float with brass handle, unioncoupling connected by means of 40mm white PVC flush hand using indian adopter joint including all internal fittings, such as, 15mm bras connections, 15mm GM wheel valve, 15mm brass nipple (2 Nos.), 15mm nylon connection, TW plugs, screws and also giving necessary connection to the PVC pipe and painting the CI brackets with 2 coats of approved paint over one coat of red oxide primer, dismantling the masonry and re-doing the dismantled masonry to original condition, etc., complete complying with standard specifications. (The EWC and flushing tank with all accessories should be got approved by the Executive Engineer before use on works) Floor Fitting. 82 Supplying and fixing Stainless Steel Health Faucetwith all the accessories etc, 83 Supply and fixing White without PedastalWash Hand Basin of size 550mm x 400mm with all accessories such as Cast Iron Brackets, 32mm dia CP Waste Coupling, Rubber Plug and Chain, 32mm dia B Class GI Waste Pipe, 15mm dia GM Wheel Valve, 15mm dia Nylon Connection, 15mm dia Brass Nipples,15mm CP Pillar Tap etc (The wash basin should be got approved by Executive Engineer before use on works). 84 Providing and fixing C.P. Angle stop cock of approved quality conformingto IS:8931 :15mm nominal bore 85 Providing and fixing Brass Chromium Plated Towel Rail 60cm long and20mm dia with Brackets etc,. 86 Providing and fixing Brass Chromium Plated Soap Tray of size 150mm x 100mm 87 Providing, fixing and testing of PVC soil, waste and vent pipe confirming to IS 13592 of SWR quality 6 kg / sq.cm pressure rated 10mm, including all fittings, like Bends, Tees, Elbows, Collars, junction, inspection doors, cowls, offsets, access pipes, jointing with rubber ring / solvent cementfollowed by application of leak proof adhesive like FRP paste, fixed to wall with properly fabricated MS bracket of suitable size, GI U clamps with bolts, nuts and GI washers complete, for soil and waste pipe lines. 88 75 DIA 89 110 DIA 90 Providing, fixing and testing of PVC waste pipe of agricultural sereis conforming to IS 4985 including all fittings like tees, elbows, bends, collars, coupling, etc jointing with solvent cement followed by application of leak proof adhesive like FRP paste laid on floors inside the toilets to the required slope including making necessary bores in walls / foundations / concrete slab as applicable, making good the bores with CM 1:3 or cement concrete as applicable, curing etc., complete. 91 40 DIA 92 Providing, fixing and testing of PVC floor- trap 110 dia with necessory of multitrap connection (heavy duty hinged type) with brass CP frame & cover (100 mm x 75 mm). Trap of 100 mm dia inlet and 75 mm dia outlet fixed on a bed of cement concrete etc.complete. (The frame and grating shall be approved by Architects) 93 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water Providing, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.(Concealed On Wall) 94 20MM DIA 95 25MM DIA 96 Providing and fixing gun metal gate valve with C.I. wheel of approvedquality (screwed end) : 97 25mm dia Cost of gate valve 98 32mm dia Cost of gate valve 99 Providing, installation, testing and commissioning approved make CIY-type Strainer conforming to IS standardwithnecessary companion flanges, neoprene gaskets(10Kg/sq.cm. pressure rating) nuts and bolts including all the accessories to complete the work as per the specifications. 100 32 mm nominal bore 101 Providing, fixing and testing of PVC soil, waste and vent pipe confirming to IS 13592 of SWR quality 6 kg / sq.cm pressure rated 10mm, including all fittings, like Bends, Tees, Elbows, Collars, junction, inspection doors, cowls, offsets, access pipes, jointing with rubber ring / solvent cementfollowed by application of leak proof adhesive like FRP paste, fixed to wall with properly fabricated MS bracket of suitable size, GI U clamps with bolts, nuts and GI washers complete, for soil and waste pipe lines.(Pipes Runningin the Shaft & below ground level) 102 75 DIA 103 110 DIA 104 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water Providing, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.(Pipes Runningin the Shaft & below ground level) 105 25MM DIA 106 32MM DIA 107 Providinging and fixing in position PVC Vent cowls of following dia of best approved quality conforming to BIS, etc., complete complying with standard specifications.(The PVC cowl should be got approved by the Executive Engineer before use on works). 108 75MM DIA 109 110MM DIA 110 Providing and fixing GI. puddle flanges (IS; 1239) fabricated out of 6 mmthick M.S. plate of size 300 x 300mm plusdia of pipe of 750mm long pipe pieces fixed to RCC wall of water tanks. Including painting with two coats of primer complete as required. The entire fitting shall be hot dipped galvanized.(Rate As per Quotation) 111 32 mm dia 112 40 mm dia 113 50 mm dia 114 65 mm dia 115 Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design:(Rate As per Quotation) 116 Constructing in site of Inspection chambers comprising burnt brick/solid block masonry walls of 230 mm thk., built in CM 1:4 over M-15 CC bed of thickness 100 mm ,Heavy duty RCC precast cover (SFRC), benching in CC M-15, internalfaces plastered smooth in CM1:4, 15mm thick and outside Rough Plastered with CM 1:6, 15mm thick including necessary earth work excavation returning and refilling and disposing surplus soil as directed by the Engineer in charge. 600x600 mm size internal and depth will 450mm to 1200mm & 900x800 mm size internal and depth will 450mm to 1200mm. (Rate As per Quotation) 117 600x600 118 Making of core cutting in RC slab of maximum 150mm thick of following diameter. 119 a) 150 mm dia 120 b) 125 mm dia 121 Providing and fixing MS slotted angle iron brackets, hangers, MS grip bilts,universal clamps with thereaded rod,supports with necessary drilling holes to suit the insertion of pipe clamps, deburring etc., as per detailed drawing for supporting soil, waste and rain water pipes and water Providing pipes in shafts with suitable MS clamps, bolts, anchor bolts, nuts and washers fixed on shaft walls/outer walls etc., The quoted rate shall include with the cost of brackets galvanizing with zinc alloy of 0.08 mm thick conformed to IS 1239 etc., complete as directed by the employer. 122 Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality.(600x600mm) 123 Providinging, installing, fixing, jointing, testing and commissioning of PVC Storm water pipe confirming to IS 13592 of SWR quality 4 kg / sq.cm pressure rated 10mm, including all fittings, like Bends, Tees, Elbows, Collars, junction, inspection doors, cowls, offsets, access pipes, jointing with rubber ring / solvent cementfollowed by application of leak proof adhesive like FRP paste,The quoted rate shall include necessary earth work, fittings,pipe to be laid below ground level in trenches upto required depth, dewatering, jointing of pipes, water testing and setting,refilling, and making good the same complete as required. 124 110 DIA 125 Providing, fixing and testing of Terrace Rain water outlet (110dia) with all the accessories etc,. 126 INTERIOR 127 BOOK SHELF 1 - 2100 x 400 x 2100 Carcass are 16mm MR Ply with 0.72mm Backer Laminate on both Sides, Shutters are 16mm MR ply with One Side 0.72mm Backer Laminate & Front side 1mm Matt Finish with 2mm PVC Edge Band finish. 128 MAGAZINE HOLDER - 600 x 250 x 1200 Carcass are 16mm MR Ply with 0.72mm Backer Laminate on both Sides, Shutters are 16mm MR ply with One Side 0.72mm Backer Laminate & Front side 1mm Matt Finish with 2mm PVC Edge Band finish. 129 DISPLAY UNIT AT RECEPTION - 1200 x 300 x 600 Carcass are 16mm MR Ply with 0.72mm Backer Laminate on both Sides, Shutters are 16mm MR ply with One Side 0.72mm Backer Laminate & Front side 1mm Matt Finish with 2mm PVC Edge Band finish. 130 LEDGE 5000 x600 x 750 Panels are 16mm MR ply with 1mm Matt Finish on both sides with 2mm PVC Edge Band finish mounted to the wall. 131 4SEATERLEARNINGCENTRETABLE-2000mmx1000mmx750mm -TABLE TOP: 25mm pre laminated particle board with 2mm PVC edge banding. MS 120 LEGS: Pillar are made out of heavy duty CNC cut & bend section of 120 degree which is engineer designed, E250 grate of 2.5mm thick 132 6SEATERLEARNINGCENTRETABLE-2400mmx1000mmx 750mm -TABLE TOP: 25mm pre laminated particle board with 2mm PVC edge banding. MS 120 LEGS: Pillar are made out of heavy duty CNC cut & bend section of 120 degree which is engineer designed, E250 grate of 2.5mm thic 133 READING CHAIR - Lounge Chair Uphostered in EPU Leather. Sleek Four Star Fixed Base With Revolving Function In Warm White Powder Coated Finish. Three Dimensional Lumbar Support Design. Model number SCML-SF30.1. Bosses Cabin or equivalent. 134 ROLLINGCHAIRS-Medium back chair with metal grey back frame, metal grey adjustable PU armrest (4D), moulded foam seat with metal grey shell, STG drive-by-wire mechanism with 4 position locking, polished aluminum alloy five-star base with metal grey PU castors. Model number CHT66SW. Bosses Cabin or equivalent. 135 SINGLESTUDYCHAIR:Multi-Purpose Chair Upholstered In Water Based PU Leather. Cushioned Seat and White Ash Solid Wood Legs. Model number SCMF-XCB33 - Latte Brown. Bosses Cabin or equivalent. 136 LOCKER & FOOTWEAR STORAGE- – 1950x375x470mmPLU main 2 DR numeric lock with envelop slot – 1950x375x470mm. Godrej interio or equivalent. 137 RECEPTIONDESK-1800mmx650mmx 1050mm- Reception Table In Matt White and Oak Laminate. IncludesStorage Cabinet and WireManagement Grommet OnDesk. Top Model number 28ROB003(BCRMB-OB 03). Bosses cabin or equivalent. 138 Seamlessly shift from warm, cozy tones to cool, vibrant whites (also known as tunable white or human-centric lighting) is an advanced JS3 Serial LED Connecting System LED lighting technology that allows users to adjust the color temperature of the light output — from warm to cool — to suit mood, time of day, or functional needs.LED Type: OSRAM SMD 3030Iceil™ Supply of OSRAM 24V LED Module Color Temperature: 2700K to 10000K with Iceil IP67 Drivers CRI: ≥90 – Delivers natural, true-to-life color accuracyMounting: High-performance aluminum rigid PCB– Ensures excellent thermal management and long lifespanConfiguration:– Each block features 4 high-quality LEDs– Optimized light spacing for shadow-free illumination– Viewing Angle: PMMA lens Ultra-wide 160° beam spreadDimmable: No Compatibility:DALI, Tuya Smart App, Alexa, & Google Home. Touch Panel, and RF Remote control optionsPower Consumption:– Only 4-6W per sq.ft– Energy-efficient yet high-lumen outputLighting Quality:– Uniform light diffusion across the stretch ceiling– Suitable for both translucent and printed membrane typesIceil™ Power Supply: Wide Input Range 100-305AC (Class I), Surge Protection with 6KV/4KV, Working temp. -20~ +45°C 20% ~ 90%RH, Metal case IP67, Power factor <0.98LED and Power Supply Warranty: 5 Years or 50,000 Hours (whichever comes first)Certifications: CE & RoHS Certified – environmentally safe and globally compliant Installation of pre-supplied LED lighting fixtures, associated drivers, and control systems, including all necessary mounting, wiring, terminations, and system integration by qualified technicians.The scope includes:Installation of LEDs as per lighting layoutMounting and secure placement of LED drivers and control gear in accessible locationsElectrical connections between LEDs, drivers, and controllers using appropriate cablingTesting of each circuit and commissioning of the full lighting setupRate Includes: Skilled labor, tools, basic fasteners, and all on-site installation efforts.. 139 Iceil™ supplies exclusively premium-grade of European Standard PVC Thermo-Stretchable Membrane, complying with BS1-D0 as per EN 13501-1 and Class A as per ASTM E84-2024 fire safety standards. The membrane is precision-cut to the required shape and size, with perimeter edges high-frequency welded with harpoon inserts. Installation is carried out using a durable aluminium profile framing system, ensuring a seamless, secure, and aesthetic ceiling solutionThickness 0.18 mmWeight 250–300 gsm ± 2%Light Transmission Up to 75% (for translucent type)Width Up to 5 meters (seamless); larger areas joined with invisible seamsStretching Method Thermal installation at ~50–60°C using hot air gas blower Fire Rating BS1-D0, as per EN 13501-1, ASTM E84-2024 Class A Explanation: B = Very limited contribution to fire, s1 = Little or No Smoke Production, d0 = No flaming droplets or particles Moisture Resistance 100% Moisture-proofUV Resistance Yes – does not yellow or degrade indoorsEnvironmental ROHS compliant, Phthalate-free, UL Certified - Tri-O-cresyl phosphate < 50mg per kgCertification Manufactured in ISO 9001:2015 certified factoryWarranty 10 Years (under standard indoor conditions) Installation of pre-supplied Stretch Ceiling System, including site preparation, profile fixing, membrane stretching, and finishing using specialized tools and skilled labor.The scope includesFixing of aluminum/PVC perimeter profiles as per approved ceiling layoutHeating and stretching of the pre-cut stretch ceiling membrane on-siteAlignment, tensioning, and seamless fitting of membrane onto the installed profilesIntegration of cutouts for lighting, sprinklers, air conditioning vents, speakers, etc.Final finishing, cleaning, and handover of installed ceiling areaRate Includes: Skilled labor, installation tools, on-site execution, and necessary accessories for completing the installation of the stretch ceiling. 140 The Iceil Wooden Box is built from durable MR/BWP-grade plywood, featuring a 12mm back board, 18mm vertical sides (150mm height), and dual 8mm flexible plywood layers for curved designs. The 150mm depth accommodates lighting and structural needs.Finish Options: White emulsion or PU-coated interior, or white reflective laminate; exterior customizable per client.Mounting: Reinforced corners, cross supports (wood/MS) every 2 ft, fixed with dash fasteners, threaded rods, or MS supports.Stretch Ceiling Compatibility: Suits Iceil’s PVC Harpoon Profile System with aluminium profiles for welded membranes.Lighting Integration: Base for rigid block LEDs with ventilation slots for heat dissipation. 141 Wall paper 142 Carpet Flooring 143 160A LT Metering Panel - Supply, Installation, Testing and Commissioning of CPRI approved make of panel, cubicle type, Free standing, Wall mounted, single front,14 SWG CRCA sheet steel, enclosed separate compartment for each feeder, front operated, Powder coated, indoor type dust and vermin proof, hinged lockable doors, complete with electrolytic grade copper bus bars,internal wiring, colour coding, ferrules, Panel mounting MS Channels, fasteners, etc., including all associated control wiring. The Breakerof 160A TPN MCCB and 1set of 160/5A CT with TNEB Metering provision and 1nos of 160/5A CT for APFCR . (Rate as per Quotation) 144 Supply and Erection of electrical panels Boards 145 Fabrication, Supply, Erection, Testing and Commissioning of whether proof CRCA sheet steelmade up of 2mm powder coatedMCCB Indoor Type Three Phase Changer Over panel of size (H 2100 X L 2000 X D 300 ) mm with suitable to accommodate 100A 4 pole Three phase Change Over Switch-1No. as incomer for EB Source and as incomer for DG Source, 6nos of 63A 4Pole MCCBs and 4nos of 32A 4Pole MCCBs compartment as O/G supply with the provisions to accommodate Busbar chamber and cable chamber with size of 25x6mm copper busbar 4 runs having three phase Multifunction meter with line indicators and with all necessary accessories with all other connected works etc. The panel made up of 16/18 SWG CRCA sheet steel comprising of 4 sections with separate sheet steel weatherproof and shock proof safety insulation system conforming to IE Rules with IP protection, and with the panel should be painting by powder coating finishing etc.,as complete and making good of the panel with neat finishing. (Switch make : L & T / ABB) panel should be earthing confirming ISI specifications. The panel should be erected on Anchor fastners, bolts and nuts for mounting the Indoor Panel as directed by engineer-in charge/department superior engineers. Including Bus bar support, Cost ofWeldding charges for mounting the panel, Rotary Handle, Spreader Terminal, Multifunction Meter digital type / MFM 5010 LED meter CI 0.5S 146 Fabrication, Supply, Erection, Testing and Commissioning of whether proof CRCA sheet steelmade up of 2mm powder coatedMCCB Indoor Type 50 kVAR panel of size (H 1800 X L 1800 X D 300 ) mm with suitable to accommodate Incomer 1 Nos 63A 4Pole MCCB, 7nos of 25A 4Pole MCCBs with 7% 1-10 kVAR Capacitor banks in compartment as O/G supply with the provisions to accommodate Busbar chamber and cable chamber with size of 25x6mm copper busbar 4 runs having three phase Multifunction meter with line indicators and with all necessary accessories with all other connected works etc. The panel made up of 16/18 SWG CRCA sheet steel comprising of 4 sections with separate sheet steel weatherproof and shock proof safety insulation system conforming to IE Rules with IP protection, and with the panel should be painting by powder coating finishing etc.,as complete and making good of the panel with neat finishing. (Switch make : L & T / ABB) panel should be earthing confirming ISI specifications. The panel should be erected on Anchor fastners, bolts and nuts for mounting the Indoor Panel as directed by engineer-in charge/department superior engineers. Including Bus bar support, Cost ofWeldding charges for mounting the panel, Rotary Handle, Spreader Terminal, Multifunction Meter digital type / MFM 5010 LED meter CI 0.5S 147 VERTICAL THREE PHASE MCB DISTRIBUTION BOARD WITH MCB : Supply and fixingof4way verticalTPMCBsheetsteel Industrial Type TP MCB DB with IP54 Protection of surface type fitted with bus bars and neutral links with1 No. of 63A FP MCB as Incoming and 4 Nos.of32A,10KA Triple Pole MCB in Flush with wall and making good of the concealed portion with earth connection.( Industrial Type TPMCB DB with IP54 Protections) 148 Supply and fixing of 7 segment8 way63A TPN MCB sheet steel distribution board (Higher end) with metal / acrylic doorcover flush type /surface type fitted with busbars and neutral links with single / three phase MCB outgoings and separate 4 way provision for accommodating one no. 4 pole incoming 63 A TPN MCB, 10kA, / Isolator and another separate 4 way for accommodating one no. 63 Amps, 30 mA, 4 pole ELCB / RCD (totally 8 ways in one segment) and 24 nos 6-32 A, 10kA, SP MCB / Isolators ( totally 24 nos.) for outgoing in 3 segments with label holder and provision for taking up cable for size not less than 35 sq.mm. withthe following in flush with wall with earth connection only. 149 Supply and fixing of 65 mm dia. (2 -1/2) GI pipe (class B) of 6 metre length with 300mm x 300mm x 6mm MS base plate duly welded at the bottom with concreting with construction of masonry pedestal with suitable SMC box with door arrangement to house 6A SP MCB switch, 2/4 way connector on suitable hylem sheet and supply and fixing of 90W LED Streetlight fitting with LED (Higher end) with 1 metre 32mm dia. GI pipe (class B) Complete with suitable MS clamps for LED street light fitting and SMC box with PVC unsheathed copper leads from SMC box to fitting and with painting of suitable colour 150 Supply and Fixing of24W Ceiling Lightwith PVC unsheathed copper leads from terminals to the fitting.(Make : Philips/Crompton/Havelles ) 151 Supply and Fixing of11W Bulk Head Lightwith PVC unsheathed copper leads from terminals to the fitting.(Make : Philips/Crompton/Havelles ) 152 Supply of surface-mounted 24W LED wall lights to the ideal solution for a variety of indoor lighting applications. Direct illumination of the wall and surrounding surface, as well as accent lighting for vertical structures. Featuring an aesthetically pleasing, robust construction, these lights are built to withstand all weather conditions, ensuring long-lasting performance and durability • Luminaire body made of extruded aluminium alloy (grade 6063) with die cast aluminium components and non corrosive SS fasteners • Non yellowing UV stabilized translucent polycarbonate diffuser • Luminaire integrated with 24W LED • Die-cast aluminium mounting base for easy installation onto the wall • Surface mounting on wall using hardware after connecting to the power supply • IP : 65, IK : 08 • Cable entries for through-wiring of mains supply cable • Integral constant current power supply • CRI ( Ra) : >80 • Prewired with LED driver and suitable for operating on 240V, 50Hz single phase ac supply • Available CCT : 2700K, 3000K, 4000K, 5700K. Driver Power Supply : Integral, Input Voltage : 230-240Vac, Frequency : 50-60 Hz, Power Factor : ≥0.95, THD : <10%, Surge Protection : 4KV, Efficiency : >85%, Symmetrical Light Distribution.Product Finish options: Pure polyester powder coated RAL 9004 Signal black, RAL 9007 Grey aluminium, RAL 7016 Anthracite grey, Graphite grey. CE & BIS Certified. Inhouse NABL accredited lab. Brand Name : Philips, Product SKU : 919215850004 153 Supply of LED Linear Pendant luminaire is a versatile solution for projects that demand high quality of the lighting system and high visual comfort. With its modular design, the Revo-L can be used as an individual fixture or as a combination of luminaires put together in continuous lines • Luminaire made of extruded aluminium for better thermal management • polycarbonate diffuser for optimum optical performance, • Hexa-cell (Matte Black) secondary reflector • Suitable for surface and suspended mounting • Supplied with standard suspension kit (1metre).• Cable entries for through-wiring of mains supply cable • Integral power supply • Suitable for operation on 240V,50Hz single phase ac supply• Driver Power Supply : Integral, Power Factor : >0.90, THD : <10%, Surge Protection : 4KV-6KV, Efficiency : >85%, IP 44 Rating.• Dimension: 1188 x 36 x 75, 2365 x 36 x 75, 3540 x 36 x 75.• Wattage Options : Upto 40W, Upto 80W, Upto 120W.• Mounting: Pendant Mounting, Pendant Mounting, Pendant Mounting, Surface Mounting, Surface Mounting, Surface Mounting • Product Finish options: Pure polyester powder coated, RAL 9004 Signal black, RAL 9007 Grey aluminium, RAL 9016 Traffic White • CE & BIS Certified • Inhouse NABL accredited lab. Philips SP170P LED25S-6500 PSU W5L113 OD WH Smartbright Linear 154 Supply of Input power : 8W LED Bollard luminaire designed for surface mounted. Symmetrical light distribution. Luminaire madeof extruded aluminium alloy (grade 6063), die-cast aluminium of high corrosion resistance and non corrosive stainless steel fasteners. Translucent polycarbonate diffuser. Pressure die cast aluminium mounting plate Ø100.5mm x 4mm thick with 2 elongated holes 15 x 10 to suit M8 bolts at PCD55 for surface mounting on floor. The base plate have a cable entry hole of 70 x 24 mm dia at the center. Single cable entrance via PG7 cable gland. Protection class IP65. Mechanical resistance IK08. Pure polyester powder coated RAL 9004 Signal black, RAL9007 Grey aluminium, RAL 7016 Anthracite grey, Graphite grey. Available colour temperature 2700K / 3000K / 4000K / 5700K. Colour rendering index (CRI)>80. K-Lite LED module with expected service life of at least 60,000 operating hours. Prewired with LED driver and suitable for operating on 240V, 50Hz single phase ac supply. Driver efficiency >80%, Power factor >0.9, THD <10%, Surge protection 2.5KV. Luminaire dimension : 106mm diameter x 565mm height. CE & BIS Certified. Foundation Bolt - 2 Nos of M8 Foundation J Bolt Length 150mm, 2 Nos of (Spring Washers, Plain Washers and Nuts) for each BoltInhouse NABL accredited lab. PHILIPS Bollard BCP100 LED 10W PSU GR L 750mm Solar Light 155 Supply of LED Linear Lighting to suit ceiling / wall is a slim and elegantly designed fixture, suited for varied applications offers a uniform, glareless and soft lighting.Al. Profile Housing Dimension: 1000 x 17 x 8, 2000 x 17 x 8Mounting: Surface Mounting, Product Finish: Anodized Aluminum• Luminaire made of extruded aluminium for better thermal management • PC clear / semi clear matte diffuser for excellent diffused lighting experience throughout the life of the fixture • Designed for mounting on ceiling / wall • Cable entries for through-wiring of mains supply cable • To be used with LED strip & power supply unit of suitable rating. Brand Philips Profile Shine 240 LEDs/m LED Strip | 3000K Warm White | High Brightness Linear Strip for Cove, False Ceiling, Architectural, Ambient Lighting 156 Supply of 24V 2835 Flexible LED Strip, 12W/m, Non-Integral, CCT: 2700K, 4000K, 6500KDimension: 5m / Roll, IP : 67, Brand Name : K-Lite, Code : 7289 or equivalent 157 24V Power supply, IP 67 Rated SMPS suitable for 24V LED Strip lights. Wattage: 150W, 24V Series Waterproof IP67 Power Supply24Vdc 6.25 Amps 150W Power unitDimension: 313 x 43 x 34IP : 67,Brand Name : K-Lite, Code : 8198 or equivalent 158 Supply and fixing of Fans and Air Circulator 159 Supply and fixing of 1200mm (48) sweep AC ceiling fan 5 star rated complete ( Higher end)with 2 module 100W fan step regulator (Higher end)with 2.5 metre down rod with fan clamp, and wiring to the near by point with 1.5 sqmm FRLS , PVC insulated copper wires, including necessaryaccessories and hardwares as required. (SD -563) 160 Supply and fixing of 600mm wall mounting Air circulator and wiring to the near by point with 1.5 sqmm FRLS , PVC insulated copper wires, including necessaryaccessories and hardwares as required. (SD -563) 161 Supply and fixing of 300mm(12)sweep (Heavy duty) AC Exhaust fan complete with necessary wall opening and making good of the wall and wiring to the near by point with 1.5 sqmm FRLS PVC insulated copper wires including necessaryaccessories and hardwares as required. 162 Supply and fixing oflouvers shutter arrangements for 300mm(12)sweep (Heavy duty) AC Exhaust fan complete 163 Supply and laying of following XLPE armoured LTUG cable in a trench/Tray with suitable cable tie tag etc as required. 164 Supply and Laying of 3 1/2 x 50 sq.mm. PVC Al.Armoured LTUG cable in suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good. 165 Supply and Laying of 4C x 16 sq.mm. PVC AL. Armoured LTUG cable in suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good.Main Panel to DB 166 Supply and Laying of 3C x 2.5 sq.mm. PVC Cu. Armoured LTUG cable in suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make goodMain Panel / DB to Street Lights 167 Supplying & Laying 120mm/103.5mm HDPE Pipe as per requirements including excavation & refilling. 168 Supply and fixing of double compression brass cable gland for following Aluminium conductorXLPE insulatedarmoured cable of 1100 V grade with earth connection. 169 Supply and fixing of brass cable gland for3 1/2 Cx 50 Sq.mm PVC LTUGAl. Armoured cable with earth connection 170 Supply and fixing of brass cable gland suitable for4C x 16 PVC Al. Armoured LTUG cable with earth connection. 171 Supply and fixing of brass cable gland for 3C x 2.5 sqmm COPPER cableLTUG cablewith earth connection. 172 Supply and providing cable end termination of the following sizePVC LTUG aluminium armoured cable with necessary aluminium cable sockets by crimping etc with electrical connection complete (copper sockets for copper cables and Alu. Sockets for alum. Cable) 173 Supply and providing cable end termination of3 1/2Corex 50Sq.mm PVC LTUG Al. Armoured cable with necessary aluminium cable sockets by crimping etc., with electrical connection complete. 174 Supply and providing cable end termination of 4 C x 16sq.mm PVC LTUG Al. Armoured cable with necessary aluminium cable sockets by crimping with electrical connection complete. 175 Supply and providing cable end termination of 3C X 2.5 SqmmPVC LTUGCopper cable with necessary copper cable sockets by crimping etc, with electrical connection complete. 176 Wiring with 2 x1.5 sq.mm. (22/0.3) PVC insulated single core unsheathed copper conductor of 1100 V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessories with suitable Module GI switch box in flush with wall with 1 no. 6A one way module switch and 1 no. 6A 3/2 pin module socket with module front plate with continuous earth wire connection by 2.5 sq.mm. PVC insulated SC unsheathed copper wire and making good of the concealed portion with painting of suitable colour for concealed PVC pipe Plug point ( 8 points / Coil) Higher End (SD-375) 177 Wiring with 2 x 4 sq.mm. (56/0.3) PVC insulated single core unsheathed copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with PVC accessories with suitable Module GI switch box in flush with wall with 1 no. 16A one way module switch and 1 no. 16A 3/2 pin module socket with module front plate with continuous earth wire connection of 14 SWG TC wire and making good of the concealed portion with painting of suitable colour for Concealed PVC pipe power Plug point ( 8 points / Coil)Higher End (SD-385) 178 Supply and fixing of 25A Flushtype Wall Socket 25A DPMCB complete set for ACPlug inflush with wall with earth connection (For AC Plug) 179 Supply and Run of 2 of 4 sq.mm. (56/0.3) PVC insulated SC unsheathed copper conductor of 1100 V grade in suitable PVC rigidpipe Concealed inwall and ceiling with continuous earth wire connection by 2.5 sq.mm. PVC insulated SC unsheathed copperwire and making good of the concealed portion withsuitable colour. ( SD 430 ) 180 Supply and Run of 2 Run x 2.5 sqmm and 1R of 1.5sq sqmm PVC insulated SC unsheathed Cu.Conductor of 1100V Grade in suitable Pvc conduit pipe onconcealed wall and ceiling with continuous earth wire connection with painting of suitable colour. 181 Earthing as per the ISI specification with an earth electrode of 2.10 metre Class B GI pipe of dia not less than 50mm and 2 mtr long earth electrode of low carbon steel rod with 100 micron bonding and 25 kgs of carbon based environment friendly backfill compound and suitable clamp andwithcopper earth plate of size 125mm x 50mm x 6mm with necessary funnelling arrangements with necessary masonry work and with 38mm RCC cover slab for the brick masonrySD-233 182 Supply and Run of 1 of No.8 SWG copper wire in suitable PVC rigid pipe on wall / floor / ground for earth connection 183 Supply and Run of 1 of25.6.25 mm Al. Flat on wall / floor / ground for earth connection. 184 Supply and Run of 1 of25.6.25 mm Cu. Flat on wall / floor / ground for earth connection. 185 Supply, Installation, Testing and commissioning of 40 channel NVR with 4TB HDD * 4nos, Up to 40-ch 8 MP IP cameras can be connected, Connectable to the third-party network cameras Compression and Recording, H.265+ compression effectively reduces the storage space by up to 75%, Full channel recording at up to 12MP resolution HD Video Output  HDMI1/VGA1 outputs provided  HDMI1 Video output ) resolution Storage and Playback, Up to 4SATA interfaces and 1 eSATA interface for HDD connection, Support upto 6TB capacity for each HDD, Smart search for efficient playback.(Make: Hikvision/Dahua/Panasonic) 186 Supply of 8MP, Internet Protocol fixed BULLET CAMERA with following specification:●1/2.5 Progressive Scan CMOS, ● 3840 × 2160 @15 fps,2.8/4 mm fixed lens,01 lux @ (F1.2, AGC ON), 0.028 lux @(F2.0, AGC ON), 0 lux with IR, H.265+, H.265, H.264+, H.264, 2 Behaviour analyses ( Line crossing detection, intrusion detection)● Face Detection ● 120dB WDR, ● BLC/3D DNR/ROI, IP67 complied●On-board Storage -Built-in micro SD/SDHC/SDXC card slot, up to 128 GB,● Shutter Speed 1/3 s to 1/100,000 s, ● 3-Axis Adjustment Pan: 0° to 360°, tilt: 0° to 100°, ● rotate: 0° to 360°, 2.8 mm, ● horizontal FOV: 102°, vertical FOV: 53°, diagonal FOV: 124°, ●Lens Mount M12 ● IR Range I5: up to 50 m, ● Image Settings Rotate mode, saturation, brightness, contrast, sharpness adjustable by client software or web browser, ● Power Consumption and Current-12 VDC, 0.7 A, max. 7.5W PoE: (802.3af, 36V to 57V), 0.3 A to 0.2 A, max. 9W● Camera out fitted with metal housing so as to prevent the lens from damages during physical abuse.All including suitable camera stand and accessories. (Make: Dahua/Panasonic) 187 Supply, Installation, Testing & Commissioning of IP Network TDN Low-Light IR Dome Each Cameras, 1/2.8 CMOS,4 MP 2592 x1520 or better , triple stream, Min. Illumination required 0.005 Lux/F2.0 (Color,30IRE), 0 Lux/F2.0 (IR ON), 140dB True WDR, triple stream,3 to 12 mm, F1.4 to 2.8 , MFZ, Backlight Compensation, Highlight Compensation 3DNR, Privacy Mask, Internal/External Smart IR LEDs with up to 50m IR distance, H.265& |MJPEG, Inbuilt Video Analytics: Smart Motion Detection, Intrusion Detection, People Counting, Multiloitering, Face Detection, Line Crossing, Missing Object detection, [Unattended Object Detection. THe camera shall have inbuilt cyber security FIPS Chipset.Audio Stream Full Duplex, 1TB SD card support, IP 67 & IK10, Alarm: 1 In & 1out, PoE, H.265 High Profile and MJPEG, PoE Class . Certifications: ONVIF Profile S,G,T & M compliant, NDAA 889 UL, CE, EN, FCC & RoHS compliant and with all accessories and as per detailed tender specifications. 188 Supply, Installation, Testing and Commissioning of 32 smart LED TV with following specifications a) Full HD 1920 x1080 (4K monitor) b) IPS panel c) Slim back light LED module d) 900 PMI e) Triple XD engine f) Dynamic scanning g) ANRh) True colour generatori) 8modes of picture j) picture wizardIII k) Real cinema 24P l) HDMI -3nos m) USB -3nos n) Built in LAN o) Magic remotep) Dimension 1242 x 724 x 55.1min(37). (Make: Sony/ LG /Samsung). 189 Supply and Clamping of CAT 6 armoured cable in suitable PVCPipe 1 thick on wall / ceiling with connected PVC accessories with clamps, saddles etc., complete. (Between ethernet switch to camera and radio modem)i. Application : Primary (Campus), Secondary (Riser), Tertiary(Horizontal)IEEE 802.3 : 10Base-T; 100Base-T; 1000Base-TIEEE 802.5 16 MB; ISDN; TPDDI; ATMii. Standards: ISO/IEC 11801 2nd ed.; IEC 61156-5 2nd EN 50173-1; EN 50288-6-1,EIA/TIA 568C.2, RoHS Compliant.Fire Rating: PVC : IEC 60332-1.iii. Conductor - Bare Copper Wireiv. Insulation - Polyethylenev. Twisting - 2 Cores to the pair vi. Cable lay up - 4 Core to the pair It has diameter of (23 AWG) 0.550 ± 0.015.Insulation : Polyethylene.GI wire of size is 0.90 ± 0.030mm. 190 Fixing and Termination of CAT 6 Cable RJ 45Jack Single Point( Point to Point ) Crimping, Testing and arrangement charges. 191 Supply and fixing of POE 24 port switch10/ 100 / 1000 Base -T / 2 x 1000Base-FX / 20Gbps bandwidth / IEEE803.af/at compliant PoE+ / RJ45 supports auto MDI/MDI-X function / Auto negotiation speed, half/full-duplex / Store and forward / Max packet size: 10kbytes / Wide range power design (12~56VDC) / Operating temperature (-40 ̊C ~ +75 ̊C) / Reverse polarity protection / Resettable fuse to protect against overcurrent / IP-40 protection / EFT protection for power line. 192 Supply and Fixing of Rack with Accessories -Higher end 12 U Rack with LNS unit and fan extra for the above rack. 193 Supply and Installation for 2KVA UPS with Battery, Single Phase UPS (Single Phase In & Single Phase Out) Capacity - System with Battery - 2Hours back up 194 PA SYSTEMS 195 Supply,installation, testing and commissioning of 30W High efficiency ABS horn loudspeaker with weather protectin IP 65Max Power : 45 W, Rated power, 30 Watts, Power tapping, 30/15/7.5W-Effective frequency range (-10 db) (-380 Hz to 5 kHz) - SPL at rated power (1 khz) 126 dB- Self extinguishing acc. to UL 94 VO - IP 65 acc. to IEC 60529, safety acc. to EN 60065. (Make - BOSCH) 196 Supply, installaion, testing and commissioning of 240W mixer amplifier with following features : inbuilt bluetooth for audio streaming, sports audio playback from USB pen drive, 4 microphone/line inputs, plus music source input, insert features to use as a pre/power amplifier, Optional 2 tone chime generation for input 1 technical specifications - Frequency response 80 Hz to 18 kHx (+1/-3 dB W - 10 dB ref. rated output) - Distortion <1% @ rated output power, 1 kHz bass control Max +/- 8 dB Treble control max +/- 8 dB. (Make - BOSCH) 197 Supply, installation, testing and commissioning of Goose Mic 198 Supply and installation ofHandheld microphone with a dynamic transducer element that shall be designed for high speech intelligivility. It should have a rugged enclosure is both stylish and easy to use in a wide range of public and sound reinforcement applications. Polar Pattern unidirectional, frequency range 80 hZ to 12 kHz, Sensitivity 1.7mV/Pa +/- dB, Rate out impedance 600 Ohms. (Make BOSCH) (Market rate) 199 Supply and laying of FRLS PVC insulated 2 core 1.5 sq.mm. Armoured Copper Cable on ceiling / wall using fixing accessories like screws, plug, clamps, etc., asper standard methods and as directed by the Departmental Officers. 200 Supply and Installation for 2KVA UPS with Battery, Single Phase UPS (Single Phase In & Single Phase Out) Capacity - System with Battery - 2Hours back up 201 Supply and erection, testing and commissioning of 2.0 TR (6000K.cal/hr) ABS Split type Air conditioner (3 star rating)confirming to IS : 1391(part-2) 1992 with Admt No.1 fitted withhermetically sealed air compressor operating on refrigerant R-410A suitable for wall mounting for operation on 230V 50 HZsingle phase AC supply inverter technology with capable of thefollowing performinga) Coolingb) Dehumidifyingc) Air circulatingd) Filteringe) Refrigerant pipe lines – 6 mtr lengthThe installation works for the above split type AC units includethe following1. Mounting / fitting indoor and outdoor units at theirrespective locations2. Laying refrigerant pipe line of required length notexceeding 6 meters distance & connecting both units afterdrilling hole/holes in the wall is required, thickness of the coppertubing shall not be less than 0.7 mm3. Installing the section pipe with expanded polythene foamtubing4. Laying drain pipe to throw out the condensate water beingformed within indoor unit5. Leak testing the entire system unit6. Charging refrigerant gas in the unit7. Suitable electrical wiring with to be provided with 2.5sq.mm PVC insulated copper wire between indoor and outdoorunit upto 6 meter length and upto switch within 3 meters oflocation of indoor unit. (Like (Carrier / Voltas / Blue Star /Equivalent) as directed by the department officers 202 Supply and fixing of 5 KVA slim and wall mounting (V Guardmake ) double booster voltage stabilizer for operation on 170-230V 50Hz single phase AC supply capable for 2 TR split ACwith necessary inter connection and earth connection as directedby the departmental officers. 203 LANDSCAPE 204 Supplying of plastic Potted plants Anthurium size of dia 12 inch including loading and unloading charges, transportation, etc as directed by the site in-charge 205 Supplying of plastic Potted plants Bogainvillea size of dia 12 inch including loading and unloading charges, transportation, etc as directed by the site in-charge 206 Supplying of plastic Potted plants Ficus ponda size of dia 12 inch including loading and unloading charges, transportation, etc as directed by the site in-charge 207 Providing & laying spreading & Compacting graded stone aggeragate of size 45mm to 22.4mm, 22.4mm to 2.36mm & 2.36mm to 75 microns to Wet Mix Macadam (WMM) specification including premixing the material with water at OMC in Mechanical mix plant carriage of mixed material by tipper to site, laying in uniform layers with paver in Sub base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density, rate including the cost & conveyence of all materials, labour charges for spreading, watering, rammed & consolidation and other tools & plants employed for the work etc., all complete and as directed by the departmental officers as per MORTH specification 406 IV Revision 208 Supplying and filling with M-Sand well watered rammed, and consolidated complying with relevant standard specifications etc., complete and as directed by the departmental officers. 209 ProvidingandlayingofBlackGraniteCobbleStoneflooringof approvedmake,inallcoloursandshades,laidon20mmthick cementmortar1:4(1cement:4coarsesand),jointingwithgrey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc., complete. 210 SupplyingandlayingGrassPaverblock M40grade Providingand layingof 63mm thickhighstrengthtypeconformingIS15658- 2006ofrubberizedinterlockingpaverlockinsizeofminimum compressivestrengthof40N/mm2inuniformshapeofapproved maketobelaidinflurringbonepatternwithsandcushionbelow theuniformshapofapproved nonskittingsurfaceinthetopand therateincludinglevellingthebasepreparationof paversassub base,sandcushion150mmthicklaying outofpavementcutthe piecestofixtheedgevibringthepavers,sweepingtranporting loadingunloadingoflayingpaverblockasperstandard specification,.
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 3
36.
Housing Urban and Rular Development #10204751 Price Bid
Tender For Lake Front Development At Porur Chennai.; 1 CIVIL WORKS 2 Earth work excavation for foundation in all soils and sub-soils and to full depth as may be directed except in rock requiring blasting inclusive of shoring shuttering, bailing out water wherever necessary and depositing the surplus earth within the compound in places shown by thedepartmental officers with an initial lead of 10 mts and initial lift of 2 mts. and clearing and levelling the site, etc., complete complying with standard specification. 3 Earth work open excavation in all soils and sub-soils and to full depth as may be directed except in rock requiring blasting inclusive of shoring shuttering, bailing out water wherever necessary and depositing the excavated earth with a lead of 10 mts. within the compound in places shown by the departmental officers and clearing and levelling the site, etc., complete complying with standard specification. 4 Clearing Scrub Jungle, etc., complete complying with standard specification and as directed by the departmental officers. 5 Installation of Vertical Bored cast in situ RCC piles of 300 mm diameter and M-30 grade of concrete in all types of soils, using Standardised Concrete Mix of following grade, with sulphate resistant Cement or OPC/PPC, etc and Crushed Stone Sand and 20mm and down graded HBGS jelly coarse aggregate. The rate includes cost for placing of reinforcement cage in bore hole in correct position, cost of boring to the required depth with Bentonite solution with temprory casing of required length, conveyance of RMC to site and pouring concrete using Tremine pipes, conveyance of all materials to the site including all tools and plants, shifting the plants and equipments from one point to another, excavtion of mud pits for circulation of Bentonite soultion, closing the mud pits to original level and mud removal with initial lead and lift but including dismantling the concrete above the cut off level etc complete as directed by the departmental officers including socketing. The reinforcement cage should be welded properly for lifting. The concrete cubes to be tested as per IS 456-2000. Acceptance criteria by clause 16.1. Frequency of testing as per 15.2.2. Testing to be conducted at both the ends at site as well as RMC plant. Pile driving depth should be decided by the departmental officers at site. The length of pile for payment shall be measured from top of shoe to the bottom of the pile cap. (Cost of Reinforcement provided for Pile and Welding charges shall be measured and Paid separately) 6 Installation of Vertical Bored cast in situ RCC piles of 380 mm diameter and M-30 grade of concrete in all types of soils, using Standardised Concrete Mix of following grade, with sulphate resistant Cement or OPC/PPC, etc and Crushed Stone Sand and 20mm and down graded HBGS jelly coarse aggregate. The rate includes cost for placing of reinforcement cage in bore hole in correct position, cost of boring to the required depth with Bentonite solution with temprory casing of required length, conveyance of RMC to site and pouring concrete using Tremine pipes, conveyance of all materials to the site including all tools and plants, shifting the plants and equipments from one point to another, excavtion of mud pits for circulation of Bentonite soultion, closing the mud pits to original level and mud removal with initial lead and lift but including dismantling the concrete above the cut off level etc complete as directed by the departmental officers including socketing. The reinforcement cage should be welded properly for lifting. The concrete cubes to be tested as per IS 456-2000. Acceptance criteria by clause 16.1. Frequency of testing as per 15.2.2. Testing to be conducted at both the ends at site as well as RMC plant. Pile driving depth should be decided by the departmental officers at site. The length of pile for payment shall be measured from top of shoe to the bottom of the pile cap. (Cost of Reinforcement provided for Pile and Welding charges shall be measured and Paid separately) 7 Installation of Vertical Bored cast in situ RCC piles of 450 mm diameter and M-30 grade of concrete in all types of soils, using Standardised Concrete Mix of following grade, with sulphate resistant Cement or OPC/PPC, etc and Crushed Stone Sand and 20mm and down graded HBGS jelly coarse aggregate. The rate includes cost for placing of reinforcement cage in bore hole in correct position, cost of boring to the required depth with Bentonite solution with temprory casing of required length, conveyance of RMC to site and pouring concrete using Tremine pipes, conveyance of all materials to the site including all tools and plants, shifting the plants and equipments from one point to another, excavtion of mud pits for circulation of Bentonite soultion, closing the mud pits to original level and mud removal with initial lead and lift but including dismantling the concrete above the cut off level etc complete as directed by the departmental officers including socketing. The reinforcement cage should be welded properly for lifting. The concrete cubes to be tested as per IS 456-2000. Acceptance criteria by clause 16.1. Frequency of testing as per 15.2.2. Testing to be conducted at both the ends at site as well as RMC plant. Pile driving depth should be decided by the departmental officers at site. The length of pile for payment shall be measured from top of shoe to the bottom of the pile cap. (Cost of Reinforcement provided for Pile and Welding charges shall be measured and Paid separately) 8 Refilling with excavated earth in layers of not more than 15 cm thick well rammed, watered and consolidated etc. complete complying with standard specification. 9 Supplying and filling with earth up to 10 Km for foundation and basement, etc., including watering and consolidating, etc., complete complying with standard specifications and as directed by the engineer-in-charge 10 Supplying and filling in foundation, basement, etc with Stone Dust in layers of not more than 15 cm thick well watered, rammed and consolidated etc. complete complying with standard specification and as directed by the departmental officers. 11 Supplying and filling in foundation, basement, etc with Crushed Stone sand filling in layers of not more than 15 cm thick well watered, rammed and consolidated etc. complete complying with standard specification and as directed by the departmental officers. 12 Plain Cement Concrete 1:4:8 (one part of cement, four part of Crushed Stone Sand (M- Sand) and eight part of coarse aggregates) using 40mm size ISS HBG metal including cost and conveyance of all materials to site and including for the mixing, laying and labour charges and all incidential charges such as water providing etc., complete as per standard specification 13 Plain Cement Concrete 1:2:4 (one part of cement, two part of Crushed Stone Sand (M- Sand) and four part of coarse aggregates) using 40mm size ISS HBG metal including cost and conveyance of all materials to site and including for the mixing, laying and labour charges and all incidential charges such as water providing etc., complete as per standard specification 14 Construction of Granular sub-base of required compacted thickness by providing laying, spreading and compacting of Close graded Material conforming to Grading V of Table 400-1 of MORTH clause 401,mixing in a Wet Mix Plant of 200 tonne capacity at OMC, carriage of mixed material to work site, spreading in uniform layers with motor grader on prepared surface and compacting with vibratory roller 8-10 tonne to achieve the desired density of 98% including protection of edges of GSB layer, cost of all materials, labour, hire charges of machinery, lighting, guarding, barricading, maintenance of diversion road, loading & unloading, all lead and lift etc., to achieve minimum CBR value of 30%(Compacted Thickness) in accordance with MORT&H technical specification clause No. 401 and with all other incidental charges and as per the direction of the Engineer-In-Charge of work. 15 Damp proof course with Cement Mortar 1:4 (One Cement and Four sand) 12mm thick mixed with best approved quality water proofing compound conforming to Indian Standard specification as specified by the departmental officers at 2% by weight of cement used and finishing, curing etc. complete complying with standard specification. 16 Providing Anti-termite treatment to soil adjecent and under building foundation, plinth periphery of the building by application of chemicals of IS 63613 part I to IV in stages to suit the progress of work consist as per the detailed specification as below.Including breaking of termite mounds, making holes with crow bar, closing the holes after the treatment and including cost of chemicals, labour charges, transport and storing etc., complete and as directed by the departmental officers. 17 Random Rubble masonry in Cement Mortar (1:3) etc., Complete complying with standard specification and as directed by the Departmental Officers 18 Supplying and erecting steel centering including necessary supports for plane surfaces for Reinforced Cement Concrete works such as column footings, column pedestals, plinth beams, grade beams, staircase steps, etc. which require only nominal strutting using mild steel sheets of size 90cm x 60cm and 10 BG stiffened with welded mild steel angles of size 25mm x 25mm x 3 mm for boarding, laid over silver oakjoists of size 10cm x 6.5cm spaced at about 75cm centre to centre or at suitable intervals etc. complete in all floors complying with standard specifcation. (Payment for centering shall be given after the concrete is laid). 19 Supplying and erecting centering for sides and soffits including necessary supports and strutting upto 3.29 M height for plane surfaces as detailed below in all floors with all cross bracings using Mild Steel sheets of size 90 x 60 cm and 10 BG stiffened with welded Mild Steel angle of size 25mm x 25mm x 3 mm for boarding laid over silver oak joists of size 10cm x 6.50 cm spaced at abote 90 cm centre to centre and supported by casurina props of 10cm to 13 cm dia spaced at not more than 75 cm centre to centre etc. complete complying with the standard specificaiton. (Payment for centering shall be given after the concrete is laid). 20 For plane surfaces such as RCC floor slab, roof slab, beams, lintels, bed blocks, landing slab, waist slab, portico slabs and beams, etc. 21 For plane surfaces such asrectangular or square RCC columns, sunshades, top and bottom slab of RCC boxing, etc. 22 For plane surfaces such as vertical slab, side slabs of boxing, vertical drops, facia, vertical wall, etc. 23 Centering for curved surfaces of all RCC items of work 24 Providing additional strutting to centering of RCC slabs of plain surface for every additional 1.0 metre height or part there of but not less than 30 cm, over the initial 3.00 metre height from floor level using casurina props of 10cm to 13cm dia including cross bracing etc., complete complying with standard specification and as directed by the department officers. 25 Providing and laying in position, Standardised Concrete Mix M-25 Grade in accordance with IS:456-2000, using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement content of 350 kg/mᶾ and maximum water cement ratio of 0.50, including admixture (plasticiser / super plasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability with about (5.0 cu.m.) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 cu.m.) 5156 kg. of 10-12mm machine crushed stone jelly and with about (4.79 cu.m.) 7670 kg. of sand, but excluding cost of reinforcement grill and fabricating charges, centering and shuttering and also including laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc., complete complying with standard specification and as directed by the departmental officers.The coarse and fine aggregates to be used should comply with the requirements of IS Standards.(No separate payment will be made by the Department for the excess usage of materials). 26 Foundation and Basement 27 For Ground Floor 28 For First Floor 29 Providing and laying in position, Standardised Concrete Mix M-30 Grade in accordance with IS:456-2000, using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement content of 400 kg/mᶾ and maximum water cement ratio of 0.45, including admixture (plasticiser / super plasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability with about (5.0 cu.m.) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 cu.m.) 5156 kg. of 10-12mm machine crushed stone jelly and with about (4.79 cu.m.) 7670 kg. of sand, but excluding cost of reinforcement grill and fabricating charges, centering and shuttering and also including laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc., complete complying with standard specification and as directed by the departmental officers.The coarse and fine aggregates to be used should comply with the requirements of IS Standards.(No separate payment will be made by the Department for the excess usage of materials). 30 Foundation and Basement 31 Supplying, fabricating and placing in position Mild Steel / Ribbed Tor Steel reinforcement grills of all variety like HYSD/CTD/TMTand all grade like Fe 500, Fe550D, Fe 500 D etc., for all RCC works as per design given including cost of steel reinforcement and G.I. binding wire, wastage etc. complete complying with standard specification and as directed by the departmental officers.(Contractor has to make his own arrangements for the supply of steel reinforcement and binding wire) 32 Brick work in Cement Mortar 1:3 using best quality of Second Class Ground Moulded Chamber Burnt Bricks 9 x 4-3/8 x 2-3/4 for foundation and basement including curing, etc., complete complying with standard specifiction. 33 For foundation & basement 34 In Ground floor 35 In First floor 36 Brick partition walls of 11.50cm thickness using best quality II Class Ground Chamber Burnt Bricks of size 9 x 4-3/8 x 2-3/4 in Cement Mortar 1:3 (One Cement and Three Sand) using hoop iron reinforcement if found necessary including curing etc. complete and as directed by the departmental officers. (Hoop iron reinforcement will be measured and paid for separately). 37 Ground floor 38 Weathering course in brick jelly lime concrete using broken brick jelly of size 20mm uniform gauge in pure slaked lime (no sand to be used) to the proportion of brick jelly to lime being 32:12.5 by volume and laid over the RCC roof slab in a single layer of required slope and finished by beating the concrete with wooden beaters of approved pattern, keeping the surface constantly wet by sprinkling lime jaggery water, etc., complete as per standard specification and as directed by the deparmental officers. 39 Inner Plastering with Cement Mortar 1:5 (One cement and Five sand), 12mm thick in all floors including curing etc. complete complying with standard specification and as directed by the departmental officers. 40 Outer Plastering with Cement Mortar 1:4 (One cement and Four sand), 20mm thick in all floors including curing etc. complete complying with standard specification and as directed by the departmental officers. 41 Special ceiling plastering and finishing the exposed surface of all RCC items of work such as slabs, beams, sunshades, facia, canopy slab, staircase waist slab, landing slab etc., with Cement Mortar 1:3 (One Cement and Three Sand) 10mm thick including hacking the surfaces, providing cement mortar nosing, beading for sunshades, staircases, steps, landing slabs and curing, etc., in all floors complying with standard specification and as directed by the departmental officers. 42 Providing Polymer Coating (Water Proof Coating) for sunken portion of toilet with following specification and the surface shall be cleaned to remove all dust, foregin, matters lose materials or any other deposits of contamination by rubbing with wire brush.Slurry: Dry blend and polymer liquid blend shall be mixed into the desired ratio as per recommendation of the supplier. The mix shall be stirred thoroughly until no bubbles remain in the mix. Any lumps found in mix shall be removed.Apply first coat of polymer modified cementitious slurry by brush on wet cleaned surface. After drying, second coat shall be applied on the first coat as directed by the departmental officers etc. The rate inclusive of cost of materials and labour, etc., complete. 43 White washing two coats with freshly burnt white shell lime in all floors including cost of lime, blue powder fevicol type gum, brushes, scaffolding charges, etc., complete complying with standard specification and as directed. 44 Supplying and painting the walls with two coats of wall putty as instructed by the departmental officers including preparation of surface curing, etc., complete in all floors complying with standard specifications and as directed by the departmental officers. (The wall putty shall be got approved by the Executive Engineer before use of work). 45 Painting newly plastered wall surface with two coats of ready mixed plastic emulsion paint of first class quality and of approved colour over a priming coat including thorough scrapping, clean removal of dirt, and including necessary plaster of paris putty, wherever required etc., complete complying with standard specification. Interior painting 46 Painting two coats of newly plastered wall surface with ready mixed Exterior emulsion paint of first class quality and of approved colour over a priming coat including thorough scrapping, clean removal of dirt, and including necessary plaster of paris putty, wherever required etc., complete complying with standard specification. 47 Painting new wood work with two finishing coats of synthetic enamel ready mixed paint of approved quality and colour over one coat priming coat in all floors including the cost of primer etc., complete complying with standard specification. (The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.) 48 Painting new iron works such as steel doors, windows, ventilators, window bars, balustrades etc., with two coats of best approved first quality and colour of synthetic enamel paint over the existing red oxide priming coat in all floors excluding cost of priming coat etc., complete complying with standard specification. (The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.) 49 Finishing the top of roof with one course of machine pressed tiles of size 230mm x 230mm x 20mm of approved quality set in Cement Mortar 1:3 (One Cement and Three Sand) 12mm thick mixed with water proofing compound conforming to ISS at 2% by weight of cement used and the joints pointed neatly to full depth of tiles with the same cement mortar mixed with red oxide and water proofing compound including curing etc., complete complying with standard specification and as directed by the departmental officers. 50 Flooring with first quality design ceramic tiles of all colours of size 305 x 305 x 6 mm laid over 20 mm thick cement mortar 1:3 (One Cement and Three Sand)base mortar over the existing slab / floor including cutting the tiles to the required size with special cutter wherever necessary, laying in position and pointing with white cement mixed with colouring pigment at the rate of 0.3 Kg. / sq.m. etc., complete complying with standard specification.(The make and brand of the tiles should be got approved by Executive Engineer before use on works) 51 Paving the floor with best quality Double Charged Vetrified Tiles of size 600 x 600 x 8mm of approved colour, shade and quality laid in cement mortar 1:3 (one cement and three M-sand) 20mm thick in all floors and the top pointed with the white cement mixed same colour pigments etc., complete complying with standard specification.(The make and brand of the tiles should be Johnson / Kajaria / Somany / Nitco / RAK which has to be got approved by Executive Engineer before use on works). 52 Providing And Fixing Machine Dressed Grey Granite Slab All Sides Machine Cut of Size 0.60 M X 0.60 M Size And 50 mm Thick Granite Slabs For Platform(Pavement) Including Cost And Conveyance ofGranite From Available Source Including Labour Charges For Fixing the Slab In Position To The LineLevel And GradientIncludingPointing With cm.1:3 And All Other Incidental Charges Etc.Complete 53 Paving the floor with best approved quality fine polished Granite Stone Slabs of size 1200 x 600 of 18 / 20mm thick of Synthetic Grey, Paradise andsimilar varieties with machine cut edges laid over a cement mortar bed of 20mm thick using cement mortar 1:3 (One cement and three sand) fixing the slabs with required cement slurry and laid in true right angles with minimum possible width of joints and pointing the joints with white cement mixed with mathcing colouring pigments etc., The granite stone slabs and other materials to be used shall be got approved by the Executive Engineer concerned before use on work, etc., complete as per standard speicification. 54 Paving the floor with Cement based Hydraulically pressed Anti skid tiles (pattern design) - 20 mm thick (Required shape and design) of 20mm thick of approved quality and colour laid in Cement Mortar 1:3 (One Cement and Three sand) 20mm thick and pointed with white cement mixed with colouring pigment at the rate of 0.40 Kg. / sq.m., curing, etc., complete complying with standard specification and as directed by the departmental officers.(The make and brand of the tiles should be got approved by Executive Engineer before use on works). 55 Dadooing walls with Colour designed digital print ceramic tiles, with borders, with size of 300mm x 450mm x 8mm and above set in Cement Mortar 1:2 (One Cement and Two M-sand)10mm thick and pointing the joints with white cement mixed with colouring pigments at the rate of 0.40 Kg. / sq.m. nbatly in all floors, curing, etc,,complying with standard specification and as directed by the departmental officers. (The make and brand of the tiles should be like Johnson / Kajaria / Somany / Nitco / RAK or Equivalent which has to be got approved by Executive Engineer before use on works). 56 Manufacturing, Supplying and Fixing of Stainless Steel Hand rails for staircase using 50mm dia 304L Grade Stainless Steel pipe of 1.60mm thick at required locations to a height of 900mm from finished floor level welded to 38mm dia Stainless Steel pipe post of 1.00mm thick as vertical at 900mm centre with 2 Nos. of 25mm dia intermediate horizontal stainless steel pipe of 1.60mm thick in between.The vertical pipe has to be welded to the 100 X 100 X 6mm MS base plate encased in the base concrete.The rate is inclusive of the charges for cutting, bending, welding, grinding, polishing, conveyance, electrical charges, etc. complete 57 Nosing the granite slab - single nosing as directed by the engineer-in-charge 58 Grooving the granite slab as directed by the engineer-in-charge 59 Manufacturing, supply & fixing of precast kerb stone of size 400mmx259mmx200mm thick made of M 20 grade of concrete rectangular in shape with one corner chamfered by 100 mm x 100 mm as per approved design i/c cost of all material, labour and curing etc., complete. as per IRC 5758 - 1984. 60 Supplying and laying hydraulic pressed monolithic natural grey colour cement concrete inter locking paver block of 63mm thick, in cement concrete 1:2:4 (one cement, two sand, four aggregate) using difference design and with stand for pressure of 150 - 200 kg/m2 over the existing sand cushion by using earth rambers and also vibratting the concrete blocks often laying using plate vibrators etc, complete as directed by the departmental officers. 61 Supplying and fixing of M.S.grill of approved design for grill gate, grill work to doors and windows openings ramp etc., using necessary mild steel flats for inner and outer members which should be fixed on edges including priming coat of best approved quality red oxide primer etc., complete complying with standard specification. 62 UPVC Window Specification:Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Windows of casement type (open) from the profile the size of outer frame 60mm x 58mm and shutter profile are reinforcement with GI/1mm 125GSM and 100% corrosion free, the profiles are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with over all the edges of frame and shutter the shutter will be provided with Espag multi power point locks and also it operates as handle.The corners and joints should be welded and cleaned.Radiations free pin headed plain or brown colour glass 4mm thick should be provided to the shutter and it should not allow leakage of water even at most ranging storms and should have key lockable action, security protective hinges, strong lockingsystems and as per size for arresting noise and energy loss.The connecting mechanism between sash and outer frame that enables opening of the window.The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames.The window should be got approved from the Executive Engineer before use on work 63 Providing UPVC (Un-Plasticized Polyvinyl Chloride) Door: Providing and fixing casement doors fabricated from un-plasticized polyvinyl chloride (uPVC) sections. Profiles: The profiles should be three chamber system which provides high insulation properties with outer frame 60mm x 55mm with an outer wall thickness of 2.4mm. The window unit should be designed with all corner joints mitred and fusion welded. Windows should be steel reinforced with 25 x 24 x 25mm steel reinforcement with a thickness of 1mm to have dimensional stability. The sash should be of 60 x 102mm. The mullion should be of 60 x 74mm.The profiles should have co-extruded seals. Hardware: All the hardware like friction stays, handles should be screwed with self tapping screws. The handles, locks should be designed so that they cannot be released from outside. Glazing: The window system should be glazed with 5mm plain float glass / 6mm bison lam Installation: The profiles should be cut to length and welded 45 degrees. The window should be designed such that the water drainage does not pass through the reinforcement chamber.The window system should be fixed directly to the plastered brick wall using self expanding nylon plug and driving ms electroplated screws into plug. 64 ABS DOOR Specification:Providing and fixing of ABS (Acrolynitrile Butadiene Styrene) Door using factory made plain FPVC (Foamed Polyvinyl Chloride) door frame of the size 105 x 40mm with a wall thickness of 10mm made out of extruded rigid FPVC profile mitre joined with 10 Nos. of 50mm long screw.The door frame shall be fixed to the wall by using 80mm long screws through the frame with the help of PVC fasteners to be provided for each vertical member, stiffeners of (‘U’ Channel of size 29 x 9 x 1mm, 150mm long) 3 Nos. at hinge point, frame reinforcement of (‘U’ GI Channel of size 46 x 22 x 0.06mm), bottom tie rod of (‘U’ GI Channel size of 15 x 15 x 1mm), the ABS Shutter of 35mm thick factory made plain pre-laminated.ABS (Acrolynitrile Butadiene Styrene) door shutter moulded in different designs, consisting of all round Frame made out of water proof solid foam PVC bar of size 20x32mm, reinforced by 32 x 32mm - 2 Nos. for vertical made out of LVL (Laminated Veneer Lumber), core material of 32mm thick high density craft paper honey comb board, sandwiched on both sides with pre-laminated ABS sheet thickness of 1.5mm.PVC edge banding of size 0.45mm on the vertical sides.Hardware made out of ball bearingbutterfly hinges - 3 Nos. for each shutter and ISI make SS round lock complete, including cost of Materials, conveyance and all other incidental charges and labour charges for fixing the Door neatly etc., complete complying with the standard specification. The door shutter and frame should be got approved from the Executive Engineer before use on workPlain Pre-laminated Door 65 Fabrication supply and fixing in position of aluminium natural colour matt finish louvered ventilator in all floors made with extruded aluminium section of following size with necessary accessories such as rubber beading, best quality of handle including supplying and fixing of 4 mm thick plain glass including cost of all materials, labour power consumption required for fabrication drilling holes in RCC column/floor slab/ masonry wall wherever necessary with power drills to the required extent and making good to the original condition after fixing etc., and as directed by the departmental officers etc. complete.The aluminium frames to be anodised under electrically controlled condition in accordance with ISI 1868/ 1962 specification for an average anodic film thickness of not less 15 microns and all the materials should be got approved by the Executive Engineer before use on work. Outer frame alround section of size 62x38x2mm @ 1.174 kg/ m vertical louvered section of size 60x30x4mm @ 1.27 kg/m and aluminium clips of size 19.05x10.27/11.05x1.20mm @ 0.169 kg/m. 66 Supplying, fabricating, erecting structural steel work for roofing welded or bolted type using MS channels, angles, plates and round bars etc. conforming to IS specification including primer coating and enamal painting as per Design given by the departmental officers etc, complete as per standard specification 67 Roofing with best quality prelaminated Polycarbonate Sheet 6mm thick of approved colour design and quality including cost of self tapping screws between washer and cutting the sheet to required slope if found necessary during execution of work, including charges for machine etc., complete, as directed by the engineer-in-charge 68 Supplying and fixing of Exterior WPC louvered panel for cladding and roofing works with material specifications: Material - WPC, Size - 2900 x 200 mm, Design exterior decorative panel, Color - Brown, Usage/Application for all kinds of exterior work, Thickness - 26mm, Core Filling - Fly Ash, Packaging Type - fully packed, etc., complete as directed by the engineer-in-charge 69 Supplying and Fixing ofCNC cut perforated Enclosure for EB transformer and EB pillar Boxes by using CNCMS Sheet (2mm thick), doorhinged with vertical support of80X40 mm TubularPost including horizontal Support and Stiffener (40 x40 x2mm)for MS sheet including Powder coating ofall structural members and labor for fitting , welding andtransportation of thematerial from thefactory to Site as directed by the engineer - in charge. 70 Providing and fixing of Aluminium Composite Panel (ACP) 4 sided having 50 x 25 x 1.50mm frame work vertical and horizontals out of specially designed extruded sections withstand wind pressure of 180 Kg/sq.m and fabricated fixed at all level elevation and heights.The extruded section cutting and fixing required space extruded section shall be of 6063 and alloy of BSH 9 confirming T is – 63400 rate shall included to fix the main frame with necessary clamps, fasteners, bolt nuts etc.The main frame of extruded section shall be of 22843 & 22739 (H9) grade conforming to BS 4174 (or) IS 8147.Rate shall included 4mm thick ACP sheet (0.25 + 3.5 + 0.25) alstrong or equivalent fixing with spacer tape and the ACP sheet bounded with special type structural sealant of dow corning 789 or equivalent in dust free conditions the gaps between ACP sheet to be filed with whether sealant and backer rod or 12mm foam sheet to ensure water and air tightness in all complete complying with standard specification as directed by the departmental officer 71 Refixing of damaged cement concrete solid block masonry in CC 1:3:6 (One of cement, three of sand and six of course aggregate) using 6mm and below HBG stone jelly with compressive strength of 50 kg/cm2 in cement mortar 1:5 (one of cement and five of sand ) including curing and neat finish etc., complete complying with standard specification and as directed by the departmental officers at site of work 72 Supplying and fixing of cement concrete solid block masonry by using solid blocks of size 400x200x150mm confirming to IS 2145-1965 made in CC 1:3:6 (One of cement, three of sand and six of course aggregate) using 6mm and below HBG stone jelly with compressive strength of 50 kg/cm2 in cement mortar 1:5 (one of cement and five of sand ) including curing and neat finish etc., complete complying with standard specification and as directed by the departmental officers at site of work. 73 Supplying and providing chain link fence with RCC posts.The RCC postswill be of 2.5m c/c and of 2.75mheight.The post will be 100mm square at top and 150mm square at bottom 2.15m height above ground level and 0.60m below ground level, in R.C.C 1:1.5:3mix using 12 to 20mm gauge stone jelly with necessary reinforcement moulding work and rendering smooth with cement at 15kg/cu.m etc., complete and fixed in c.c. foundation in 1:4:8 using 40mm size stone jelly. The foundation is of size 45x45x90 with sand filling 15cm height. The fencing will be of chain link 75mm size, 10 gauge. The height of fence is 2.0m after leaving 75mm gap from ground level including fixing the fence with the posts using G.I binding wire, etc. complet.ISI STD 74 Supplying and fixing Country wood scantlings for door, windows, joints, rafters, etc., or any other works using country wood scantlings in following lengh and complete it in all floors including labour charges for the manufacture of frames as per standard specification. 75 Country wood scantlings below 4m in length 76 Providing two legged Scaffolding using 15cm dia casurina post of 4m over all length (3m height + 0.5m Projection + 0.5m into the ground) the distance between the two rows being 1.25 and the spacing of posts being 2.0m in both the rows with two horizontal posts with 0.5m. Overlap on either side and braces at 2.0m centre to centre including longitudinal and transvers middle braces to step up and providing a platform with country wood planks of 40mm thick and 1m width, etc. in acomplete from using coil and nails - 1RM 77 For Initial height of 3.00 metre 78 For every additional height of 2.5 m above initial height of 3 m 79 Supply and fixing of 3-seater metal garden swing chair with canopy of material and specifications: Seating capacity - 3 seater swing, Material- metal, Appearance - modern with canopy, Cushion - Included, Usage/Application - balcony, garden, lounge, etc., Cushion material - polyster, etc., complete, as directed by the engineer-in-charge 80 Supplying,erectingandFixingprecast reinforcementbench with back rest. Bench shall consist of 2 nos. L shaped bases support in natural cement color of thickness 100mm, back height 1000mm, front height 450mm, base width 620mm and 5Nos Reinforced Concrete planks in red colorandsizeof 1500x100x50mm and 1no. reinforcedconcrete plank of 150x200x50mm: manufactured by using M-30 grade concrete & reinforced suitably: all parts to be joined with galvanized nuts and bolts of suitable size. 81 Supply & placing of FRP heavy duty three compartment Dustbin of size 1200 x 450 x 900 mm with top cover 82 Supply & placing of light weight concrete Dustbin of size 450 dia x 900 mm with top cover 83 Supply and placing of Monkey DustbinFRP – 2 Layers to a height of 3½ and width of 2½ 84 WATER SUPPLY AND SANITARY WORKS 85 Supplying and fixing in position best approved of BIS quality 110 mm dia PVC rain water down fall pipes having a pressure of 4 kg. / sq.cm including cost of necessry PVC shoe, PVC bend, cast iron gratings of required diameter and special clamps, brass screws, nails, etc., and fixing of cast iron gratings at junction of parapet and the RCC roof slab including finishing neatly etc., complete. The rate shall be inclusive of cast of removable cast iron grating. The PVC pipe shall be fixed in wall with special type of U clamp at the centre of the pipe line in addition to those for more than 3.0 metre pipe length, etc., complete complying with standard specification. 86 Supply and providingPriming Tank made up of PVC, Make: SINTEX / EQUIVALENT 87 Internal water supply - Supplying, laying and jointing PVC pipes (having working pressure 10 kg. / sq.cm) of approved quality and best variety conforming to BIS of the following dia including cutting, threading and fixing PVC specials using PVC adhesives (but excluding cost of such specials) and fixing into wall with teak wood plugs, PVC clamps and screws making holes on the wall (or) drilling holes in the roof and making good the dismantled portion to original condition with necessary brick work / cement concrete and plastering neatly wherever necessary with necessary scaffolding charges, etc., complete complying with standard specifications.The PVC pipes shall be got approved by Executive Engineer before use on works. 88 For laying PVC pipes of dia 32mm 89 External Water Supply - Supplying, laying and jointing PVC pipes (having working pressure 10 kg. / sq.cm) of approved quality and best variety conforming to BIS of the following dia including cutting, threading and fixing PVC specials using PVC adhesives (but excluding cost of such specials) and fixing into wall with teak wood plugs, PVC clamps and screws making holes on the wall (or) drilling holes in the roof and making good the dismantled portion to original condition with necessary brick work / cement concrete and plastering neatly wherever necessary with necessary scaffolding charges upto 4 metre height above ground level, etc., complete complying with standard specifications.The PVC pipes shall be got approved by Executive Engineer before use on works. 90 Above Ground Level 91 For laying PVC pipes of dia 40mm 92 Below ground level 93 For laying PVC pipes of dia 50mm 94 For laying PVC pipes of dia 40mm 95 For laying PVC pipes of dia 25mm 96 Supplying, laying and jointing CPVC pipes of approved quality and best variety conforming to BIS of the following dia including cutting, threading and fixing CPVC specials using CPVC adhesives (but excluding cost of such specials) and fixing into wall with teak wood plugs, PVC clamps and screws making holes on the wall (or) drilling holes in the roof and making good the dismantled portion to original condition with necessary brick work / cement concrete and plastering neatly wherever necessary with necessary scaffolding charges upto etc., complete complying with standard specifications.The CPVC pipes shall be got approved by Executive Engineer before use on works.(Above Ground Level) (Internal Water supply) 97 Above Ground Level 98 For laying CPVC pipes of dia 32 mm 99 For laying CPVC pipes of dia 25 mm 100 Supplying and fixing in position first quality and approved variety of Gun metal Gate Valve / Wheel Valve with BIS make of the following dia including cost of shellac, thread balls, etc., complete complying with standard specifications (for both internal and external water supply arrangements).The valves to be used on work shall be got approved by the Executive Engineer before use on work. 101 Gate valve 102 Fixing Gun Metal Gate Valve of 25 mm 103 Fixing Gun Metal Gate Valve of 40 mm 104 Wheel valve 105 Fixing Gun Metal Wheel Valve of dia 25 mm 106 Fixing Gun Metal Wheel Valve of dia 40 mm 107 Providing, fixing, Testing & Commissioning of PVC Ball valve with quarter turn including all necessary fittings & accessories complete. PIMTAS / AQVASTAR make 50 mm ( 2 ) 108 Providing, fixing, Testing & Commissioning of PVC Ball valve with quarter turn including all necessary fittings & accessories complete. PIMTAS / AQVASTAR make 40 mm ( 1.5 ) 109 Providing, fixing, Testing & Commissioning of PVC Ball valve with quarter turn including all necessary fittings & accessories complete. PIMTAS / AQVASTAR make 25 mm (1.00”) 110 Supplying and fixing in position 15mm dia brass CP Pillar tap (heavy duty) of approved make conforming to BIS specifications and quality including cost of shellac, thread, etc., complete complying with standard specification and including cutting and threading wherever necessary.(Taps should be got approved by the Executive Engineer before use on the works). 111 Supplying and fixing in position Health faucet of approved make conforming to BIS specifications and quality including cost of shellac, thread, etc., complete complying with standard specification and including cutting and threading wherever necessary.(Taps should be got approved by the Executive Engineer before use on the works). 112 Supplying and fixing in position best quality and approved make Indian made white / colour glazed earthernware wash hand basin of size 550 x 400mm (with pedestal / without pedestal) with a pair of cast iron brackets, including cost 15mm dia brass CP pillar tap, 32mm dia B class GI waste pipe with rubber plug and chain, 15mm dia GM wheel valve, 15mm brass nipple, 15mm dia nylone connection, 32mm dia CP brass waste coupling including fixing of wash basin using CI brackets on to the wall in position with TW plugs and screws, rubber washers, white lead and giving necessary water supply connection and painting the brackets with two coat of painting over a priming coat of anti-corrosive paint including testing for leakages etc., complete complying with standard specification and as directed by the departmental officers. (The wash hand basin and specials should be got approved by the Executive Engineer before use on works). 113 White Glazed Wash Hand Basin 114 With Pedestal 115 Supplying and fixing in position Indian make bevelled edge mirror of approved quality and brand PVC / Fibre Glass framed 600 x 450 x 5.5mm thick mirror, shelf type with hard board backing of approved colour fixed with brass screws, rawl plug, etc., complete complying with standard specification. (The mirror should be got approved by the Executive Engineer before use on woks). 116 Supplying and fixing approved best quality brass CP towel rail 600mm long and 20mm dia with brackets of same materials including cost of teak wood plugs and CP screws, etc., complete complying with standard specifications. (The tower rail should be got approved by Executive Engineer before use on works). 117 Supplying and fixing best approved best quality brass CP soap tray of size 150 x 150mm including cost of teak wood plugs, brass screws, etc., complete complying with standard specifications.(The soap tray should be got approved by Executive Engineer before use on works). 118 Supplying and fixing in position best quality PVC soil / waste pipes of various dia having 6 kg / sq.cm. pressure BIS mark and providing leak proof joints using PVC adhesives including fixing to the wall with special PVC / MS clamp, teak wood plugs, brass screws, etc., and making connection to all sanitary fittings, dismantling masonry / RCC works wherever found necessary and making the good dismantled portion to the original condition, including testing for any leakages, etc., complete complying with standard specifications.(The PVC pipes should be got approved by the Executive Engineer before use on works). The rate for earth work excavation will be measured and paid separately in the cases where the pipe lines are proposed to laid below ground level. 119 For laying PVC pipes of dia 110 mm 120 Supplying and fixing in position PVC cowls of 110 mm dia of best approved quality conforming to BIS, etc., complete complying with standard specifications.(The PVC cowl should be got approved by the Executive Engineer before use on works). 121 Supplying and fixing in positon Indian Water Closet (Oriya type) of size 580 x 440mm white glazed earthern ware of approved quality and brand with P or S trap conforming to BIS with sand cushion and forming flooring alround the closet using 40mm broken brick jelly in lime concrete 1:2:5 (One lime, Two sand and Five brick jelly) 100mm thick and finishing the top to the required slope and including giving necessary connection to CI soil pipes (including the cost of 100mm dia CI pipe for a length of 600mm) by dismantling brick masonry wall / reinforced cement concrete roof / floor slab and making good the dismantled portion to the original condition with leakages etc., complete complying with standard specifications and as directed by the departmental officers.(The water closet should be got approved by the Executive Engineer before use on works). 122 Supplying and fixing in position white / colour glazed European Water Closet of best quality and approved make with 100 mm P or S trap connecting with CI pipe of 100mm dia / PVC pipe of 110mm dia, double flapped rigid PVC black seat and seat cover with CP brass hinges including cost of white cement, cement for packing, spun yarn, teak wood plugs, brass screws, etc., including supplying and fixing 10 litres capacity PVC / 12.5 litres capacity porcelin low level flushing tank with a pair of CI brackets, etc., complete with all fittings such as 15mm brass ball valve with polythene float with brass handle, union, coupling connected by means of 40mm white PVC flush hand using Indian adopter joint including all internal fittings such as 15mm brass connections, 15mm GM wheel valve, 15mm brass nipple (2 Nos.), 15mm nylon connection, TW plugs, screws and also giving necessary connection to the PVC pipe including cost of 600mm length of 110mm dia PVC pipe and painting the CI brackets with 2 coats of approved paint over one coat of red oxide primer, dismantling the masonry and re-doing the dismantled masonry to original condition etc. complete complying with standard specifications.(The EWC and flushing tank wiht all accessories should be got approved by the Executive Enginer before use on works). 123 White glazed European Water Closet with 10 litre capacity PVC flushing tank fixed on to wall 124 Supply and fixing in position of best Indian make white glazed earthernware lipped mouth flat back urinal of best quality and approved make of size 430mm x 260mm x 350mm with GI pipe, 32mm dia bell mouth PVC connection and waste pipe, 15mm dia GI pipe of required length, 15mm dia GM wheel valve, 15mm dia brass nipple 2 Nos., and fixing the urinals in position with necessary TW plugs, clamps, screws, etc., including dismantling masnory and re-doing the same to the original condition, etc., including painting the pipe with two coats of best quality approved synthetic enamel paint over one coat of red oxide primer and checked without any leakage etc. complete complying with standard specifications and as directed by the departmental officers.(The urinal should be got approved by the Executive Engineer before use on works.) 125 Supplying and fixing position CI Nahani Trap / Floor Trap of the following sizes with best stainless steel gratings of approved brand and quality, fixed over a bed of brick jelly lime concrete 1:2:5 (One part of lime, two part of sand and five part of 40mm gauge brick jelly) and finished with Cement Mortar 1:3 (One Cement, Three sand) including dismantling masonry works wherever found necessary and making good the dismantled portions to the original condition and giving connection to the CI / PVC pipes, etc., complete complying with standard specification. (The Nahani Trap should be got approved by the Executive Engineer before use on works).Nahani Trap of size 100 x 75mm with stainless steel gratings 126 Supplying and fixing in position 150 x 100mm P or S stoneware gully trap A grade with CI double gratings of size 150 x 150mm and 230 x 230mm at bottom and top respectively with necessary earth work excavation laid over a bed of brick jelly cement concrete 1:3:6 (One cement, Three sand and Six broken brick jelly) 150mm thick using 40mm size broken brick jelly including necessary brick work and plastering including dismantling masonry wherever necessary and re-doing the damaged portions to the original conditions using cement concrete 1:3:6 using 20mm stone jelly for fixing the gully trap and giving connections to stoneware sewer line etc., complete complying with standard specifications. [Earth work excavation, brick work, plastering shall be measured and paid separately]. The stoneware gully trap should be got approved by the Executive Engineer before use on works. 127 Supplying and fixing single phase 1 HP Monoblock pumpset as per I.S.I. specification on suitable pedestal with foundation bolt and nut including labour. Supply and fixing of starter and main switch suitable for 1 HP pumpset on suitable angle iron frame work with necessary labour including panel board.Supply and fixing 1 No. foot valve 1 for the 1 HP Mono block pumpset supply and run of 4 of 10 sq.mm. in PVC pipe with 14 SWG TC wire etc., complete. 128 Construction of Inspection chamber of size (clear 0.60x0.60x1.00) with necessary earth work excavation, sand filling, CC 1:5:10, brick work in CM 1:5, plastering in CM 1:5 12mm thick, Plastering in CM: 1:3 20mm thick, Precast slab 50mm thick, fabrication etc. complete as directed by the engineer-in-charge 129 Providing rain water recharging collection pit having a size of 900mm dia to a total height of 1200mm is 150mm above ground level and 1050mm below ground level with necessary augar bore of300mm dia to a depth of 3000mm from bottom level of collection pit and filled with 20mm HBG stone jelly inside of augar bore. The sides of collection pit provided with RCC Well ring of inner size of 900mm x 300mm x 50mm with 6mm reinforcement on both directionat 200 mm c/c using RCC 1:1/2:3 (one cement, one and half sand and three HBG jelly). The top of collection pit is finished with 50mm thick cover slab, The collection pit is filled with course river sand at top, 20mm HBG stone jelly at middle and 40mm HBG stone jelly at bottom of a depth of 300mm, 450mm and 450mm respectively. The rate is including the cost of RCC well ring and filling materials, RCC cover slab, drilling hole and labour charges for erecting the well ring etc.,and as directed by the departmental officers. 130 Supply, Fixing & commissioning of Pop up spray RD 1804 SAM PRS Series Spray bodies with high efficiency HE VAN Nozzle capable of covering radius of 0.9-4.6m at 1.0 - 2.1 Bars, pressure with Matched precipitation rate, tactile click and DU >0.7. Triple Blade Wiper Seal precisely balances flushing, flow- by and debris protection to optimize performance and durability at pop up and retraction. Precision-controlled flushing at pop-up and retraction clears debris, ensuring positive stem retraction in all soil types. Unique debris pockets hold grit in place, removing it from circulation and preventing long-term damage. Parts resistant to corrosion in treated recycled water containing chlorine. Pop spray body shall with stand upto 6.9 bar. Built-in Seal-A-Matic™ (SAM) check valve. Traps water in lateral pipes in elevation changes of up to 14 feet (4.2 m). PRS Maintains constant outlet pressure at 30 psi or 45 psi at varying inlet pressures. etc., RD1804- SAM PRS-HE VAN incl installation charges 131 Supply of large capacity Disc filter 25 M³ / Hr including installation charges. (brands like Rain Bird or equivalent) 132 Flexible polyethelene irrigation pipe 16 mm dia / 2.5 / 1.1 - 1.4 mm CL - II. Netafim including installation charges. 133 Supply of endcap, nipple, start nipple, rubber grommet 16 mm dia. Netafim including installation charges. 134 Supply of Pressure compensated dripper with 2 / 4 / 8 LPH outlet flow. Rain Bird / Netafim make including installation charges 135 Supply of Micro sprinkler of half & full circle with 55 LPH output flow with necessary micro tube & stake. Rain Bird / JISL make including installation charges. 136 BOREWELL 137 Drilling of 12 dia vertical borewell so as to have a finished size of 6 dia borewell in boulder area to any required depth as decided by the TWAD Board Officers including Transportation from one place to anothr place with in Tamilnadu State by direct or reverse rotary mud circulation method using Contractors rig tools, fuel, labourers etc 138 Drilling of Borewells anywhere in Tamilnadu including transportation from one place to another with in Tamilnadu in alluvial soil sedimentary strata of clay and sand stone shale pebbles boulders etc. By first taking a pilot bore of 140 mm/150mm dia and then enlarging to required dia direct or reverse rotary mud circulation method using rotary rigs, fuel, labour and drilling bentonite and water required for drilling at site ( Site will be shown by the TWAD Board Officers) including construction of mud pit 139 Drilling of 140/150 mm pilot bore - Upto 60 m Depth ending below ground level 140 Drilling of 140/150 mm pilot bore - From 60 m upto 90 m Depth ending from ground level 141 Drilling of 140/150 mm pilot bore - From 90 m upto 120 m Depth ending from ground level 142 Reaming 300 mm dia pilot bore to 400mm/ 450mm dia bore as directed by the TWAD Board Officer. 143 Upto 60 m depth ending below ground level 144 Reaming 140/150 mm dia pilot bore to 300mm dia bore as directed by the TWAD Board Officer. 145 Upto 60 m depth ending below ground level 146 From 60 m depth and upto 90 mt depth ending below ground level 147 From 90 m upto 120 mt depth ending below ground level 148 Supply and laying following dia PVC casing pipe with excise duty as per IS 12818 / 2010 149 200mm dia CS 150 150mm dia RS 151 Labour charges for inserting PVC casing pipes assembly (with slots or without slots) in the drilled hole including jointing the pipes with PVC couplers with cement paste etc., complete, supply and packing the annular space with pebbles of size and quality as approved by the Executive Engineer of Departmental officers. 152 200mm dia CS 153 150mm dia RS 154 Supplying and filling with river pebbles in annular space between bore and PVC pipe up to hard rock 155 Charges for developing the borewell with air compressor of 300 CFM capacity (Minimum 8 Hours) including ransportation labour and fuel charges for compressor as directed by TWAD Board Officers and conducting yieldtest by V notch method. 156 Supply ,erection and testing & commisioning of 3HP submersible pumpset in the to suit 200mm borewell of capacity of 4800 LPH @ 265Ft, max. total head of 280 Ft pumps fitted with bronze impellers and having delivery size of 40mm - 430V along with 3mts cable and manufactures standard control panel which is mandatory and as directed by the officer incharge and other required supporting items like SS hose nipple, nylon rope, clamps, bolt and nuts,GI nipple, 50mm dia HDPE hose of required length etc completed and as directed by the officer incharge. 157 Supplying and fixing single phase 5 HP Monoblock pumpset as per I.S.I. specification on suitable pedestal with foundation bolt and nut including labour. Supply and fixing of starter and main switch suitable for 5 HP pumpset on suitable angle iron frame work with necessary labour including panel board.Supply and fixing 1 No. foot valve 2 for the 5 HP Mono block pumpset supply and run of 4 of 10 sq.mm. in PVC pipe with 14 SWG TC wire etc., complete. 158 LANDSCAPING WORK 159 Supply & stacking of red earth at site to the departmental guage for pre-measurements which is of light textured, crystalline, porous and friable and not of generally acidic or neutral but not of alkaline and should be fertile, including seignior age charges, cost of transportation, loading, unloading, stacking and inclusive of all taxes etc., complete. 160 Supply of well decomposed Farm yard Manure in a powdery form, devoid of soil sand, stones, plastics and other materials, highly nutrient and which supports plant growth. 161 Supply and stacking of pit sand / earth filling sand at site to the departmental gauge for pre measurements obtained from sand deposits and should clean without solid particles 162 Mixing charges of Red soil, sand and manure uniformly (1:1:1) for Preparation of soil mixture (excluding material cost) 163 Spreading of red soil, gravel or sand including watering and rolling which hand roller for every 75 mm thickness - including hire charges of roller 164 Preparation of Mounds of various size and shape by availlable excavated/ Supplied earth in layers not exceeding 20 cm in depth, breaking clods, watering of each layer, dressing etc., lead upto 50 meter and lift upto 1.5 m complete as per direction of Officer - in - charge 165 Planting of Lilly - Hymenocallis Lilly (Spider liiy) shrub variety of height 30-45 cm in polythene bag of size 6x7 inch including loading and unloading charges, transportation, stacking of saplings at site, earth work excavation of required size, planting of sapling, refilling of excavated earth etc as directed by the site in-charge 166 Planting of Plumaria Dwarf ornamental foliage Specimen plant variety of height 105- 120 cm in polythene bag of size 16x16 inch including loading and unloading charges, transportation, stacking of saplings at site, earth work excavation of required size, planting of sapling, refilling of excavated earth etc as directed by the site in-charge. 167 Planting of Duranta new gold Plant ornamental foliage shrub variety of height 30-45 cm in polythene bag of size 6x7 inch including loading and unloading charges, transportation, stacking of saplings at site, earth work excavation of required size, planting of sapling, refilling of excavated earth etc as directed by the site in-charge. 168 Supplying and Planting of Peltophorum tree sapling of height 240 – 300 cm in polythene bag of size 20x21 inch including supporting stack of 5 cm dia casurina pole of 10 feet height, including loading and unloading charges, transportation, stacking of saplings at site, earth work excavation of required size, planting of sapling, refilling of excavated earth etc as directed by the site in-charge. 169 Planting of Bougainvillea Specimen plant variety of height 105-120 cm in polythene bag of size 16x16 inch including loading and unloading charges, transportation, stacking of saplings at site, earth work excavation of required size, planting of sapling, refilling of excavated earth etc as directed by the site in-charge. 170 Supplying and Planting of Picharidia palms variety of height 180-210 cm in polythene bag of size 16x16 inch including supporting stack of 5cm dia casurina pole of 10 height, including loading and unloading charges, transportation, stacking of saplings at site, earth work excavation of required size, planting of sapling, refilling of excavated earth etc as directed by the site in-charge. 171 Supplying and Planting of Roystonea regia (Royal palms) palm variety of height 180-210 cm in polythene bag of size 16x16 inch including supporting stack of 5 cm dia casurina pole of 10 feet height, including loading and unloading charges, transportation, stacking of saplings at site, earth work excavation of required size, planting of sapling, refilling of excavated earth etc as directed by the site in-charge. 172 Supplying and Planting of Pungam tree sapling of height 240 –300 cm in polythene bag of size 20x21 inch including supporting stack of 5 cm dia casurina pole of 10 feet height, including loading and unloading charges, transportation, stacking of saplings at site, earth work excavation of required size, planting of sapling, refilling of excavated earth etc as directed by the site in-charge 173 Supplying and Planting of Bauhinia purpurea tree sapling of height 240 – 300 cm in polythene bag of size 20x21 inch including supporting stack of 5 cm dia casurina pole of 10 feet height, including loading and unloading charges, transportation, stacking of saplings at site, earth work excavation of required size, planting of sapling, refilling of excavated earth etc as directed bythe site in-charge. 174 Supplying and Planting of Spathodea campanulata tree sapling of height 240 – 300 cm in polythene bag of size 20x21 inch including supporting stack of 5 cm dia casurina pole of 10 feet height, including loading and unloading charges, transportation, stacking of saplings at site, earth work excavation of required size, planting of sapling, refilling of excavated earth etc as directed by the site in charge. 175 Supplying and Planting of Cane Bamboo tree sapling of height 300 - 360 cm in polythene bag of size 15x16 inch including loading and unloading charges, transportation, stacking of saplings at site, earth work excavation of required size, planting of sapling, refilling of excavated earth etc as directed by the site in-charge 176 Planting of G2 grass including loading and unloading charges, transportation, stacking of saplings at site, earth work excavation of required size, planting of sapling, refilling of excavated earth etc as directed by the site in-charge. 177 CHILDREN PARK AND GYM EQUIPMENTS 178 Supply and fixing of Straight Slide - 7ftLength 450cm ( 15ft ) x Width 75cm ( 2.5ft ) x Height 210cm ( 7ft ) Slide Material : Polyethylene Slide. Slide Length : 21cm ( 7ft ), Slide platform height : 120cm ( 4ft ), Base platform size : 2ft x 2ft, Platform base : Aluminium Checkered Sheet. Center Post : 114mm OD Galvanized post, Side Post : 50mm (2) OD Galvanized post, Powder coating : Electrostatic pp coating on metal parts. Area Required : Length 600cm ( 20ft ) x Width 150cm ( 5ft ) Playing age group : 3 - 10 yrs. Children capacity : 1Specification of Material:1. All Metal posts are made of Galvanized pipes with elecrostatic powder coated.2. Play components are made of Linear low density polyethylene (LLDPE ) ,UV protected, Heat resister, smooth finished with elegent designs. 3. All fastners closed with polyethylene caps for children protection. 179 Supply and fixing of Park Spiral Slide Junior (FRP)Size: L10.5 x W6 x H7Safe Area Size: L20.5 x W5 x H11.5Material specifications:Ladder : Galvanished ‘B’ Class pipe Sliding chute 9ft BED LEG :Galvanished ‘C’ Class pipeFRP thickness 4mm. (Reinforced Polymers in 5 Layers) 450 CSM Matt, 600 Roving Mat, Isotolic gel coat with PU pigment.ISI Make pipe and MS Angle and Flat with high thicknessHigh quality NTN Ball BearingHigh quality Glossy paint with primer 180 Supply and fixing of Cross Swing - 3 Seater Length 390cm ( 13ft ) x Width 120cm ( 4ft ) x Height 225cm ( 7.5ft ) Swing Seat material : LLDPE seats fitted with Stainless steel hooks. Swing Chain : PU coated coated galvanized chain Imported. Swinging Hook : Heavy duty Aluminium pressed with sealed bearing. Swing post : 114mm ( 4.5 ) OD G.I post of wall thickness 2mm, Centre post : 114mm ( 4.5 )OD G.I post of wall thickness 2mm, Playing age group : 3 - 12yrs. Children capacity : 3Specification of Material:1. All Metal posts are made of Galvanized pipes with elecrostatic powder coated.2. Play components are made of Linear low density polyethylene (LLDPE ) ,UV protected, Heat resister, smooth finished with elegent designs. 3. Swing chain made of PU coated chain , Seat made of LLDPE ( Polyethylene), Swing hooks made of Aluminium with sealed bearings.4. All fastners closed with polyethylene caps for children protection. 181 Supply and fixing of Seesaw - SingleLength 210cm ( 7ft ) x Width 90cm ( 3ft ) x Height 60cm ( 2ft )Seesaw seat material : LLDPE - Polyethylene. Qty : 2Nos.Seesaw center & side post : 89mm ( 3.5 ) OD Galvanized post,Seesaw handle post : 32mm ( 1.2 ) OD Galvanized post,Seesaw post top cap : Heavy duty Aluminium,Powder coating : Electrostatic pp coating on metal parts.Area Required : Length 300cm ( 10ft ) x Width 210cm ( 7ft )Playing age group : 3 - 10yrs.Children capacity : 2Specification of Material:1. All Metal posts are made of Galvanized pipes with elecrostatic powder coated.2. Play components are made of Linear low density polyethylene (LLDPE ) ,UV protected, Heat resister, smooth finished with elegent designs. 3. All fastners closed with polyethylene caps for children protection. 182 Supply and fixing of Park Seesaw 4 Seater (FRP Seat)Size: L8.75 x W5 x H3 Safe Area Size: L11.75 x W8 x H6 Material specifications:Frame : 1 ½” Galvanished ‘B’ Class pipeSee saw Rail :2” Galvanished ‘C’ Class pipeSeat : FRP Seat with 450 CSM Mat 3 Layers bonding. Isotolic gel coat with UV pigment.Painting with PU coating seatISI Make pipe and MS Angle and Flat with high thicknessHigh quality NTN Ball Bearing 183 Supply and fixing of Merry go round - 6 Seater Diameter 180cm ( 6ft ) x Height 75cm ( 2.5ft )Galvanized 50mm dia pipe used for outer ring.Heavy duty Tapper roller bearing setting on the base for smooth rotation.Powder coating : Electrostatic pp coating on metal parts.Area Required : Length 240cm ( 8ft ) x Width 240cm ( 8ft )Galvanized semi circle seats - 2Nos with side saftey handles.Playing age group : 3 - 12yrs.Children capacity : 6Specification of Material:1. All Metal posts are made of Galvanized pipes with elecrostatic powder coated.2. Play components are made of Linear low density polyethylene (LLDPE ) ,UV protected, Heat resister, smooth finished with elegent designs. 3. All fastners closed with polyethylene caps for children protection. 184 Supply and fixing of Spring Rider - Dinasour Polyethylene Dinasour design attached with 22mm heavy duty coil springs mounted on 10mm Base plate. Metal part powder coated. Safe area - 6ft x 6ft. Playing age group : 3 - 10yrs. Children capacity : 2 Specification of Material:1. All Metal posts are made of Galvanized pipes with elecrostatic powder coated.2. Play components are made of Linear low density polyethylene (LLDPE ) ,UV protected, Heat resister, smooth finished with elegent designs. 3. All fastners closed with polyethylene caps for children protection. 185 Supply and fixing of Park Loop RungSize: L10 x W2 x H7.5Safe Area Size: L13 x W5 x H10Material specifications:Post-Galvanished ‘B’ Class pipeTop rail-Galvanished ‘C’ Class pipeSprings –Galvanished ‘C’ Class pipe.Painting with PU coating ISI Make pipe and MS Angle and Flat with high thicknessHigh quality NTN Ball BearingHigh quality FRP Materials with U~V resistance pigments and ISO Resign and 600 GSM Mat 186 Supply and fixing of Park Flat RotorSize: L5 x W5 x H3.25’ Safe Area Size: L8 x W8 x H6.25Material specifications:Pipes - 1’’GI pipe, 3/4”GI pipe, 3”GI pipe, 2.5mm thick, B class paint: PU coatingISI Make pipe and MS Angle and Flat with high thicknessHigh quality NTN Ball BearingHigh quality FRP Materials with U~V resistance pigments and ISO Resign and 600 GSM Mat 187 Supply and fixing of Park Arch Swing 2 Seater (FRP)Size: L10 x W3 x H6.75Safe Area Size: L13 x W6 x H10Material specifications:ARC-Frame : 2.5mm thickness Galvanished ‘B’ Class pipe Top Rail : 2” Galvanished ‘C’ Class pipe with 4.5mm thickSeats : RubberChain : 8mm Stainless Steel Chain (Grade-304)Painting with PU coating ISI Make pipe and MS Angle and Flat with high thicknessHigh quality NTN Ball BearingHigh quality FRP Materials with U~V resistance pigments and ISO Resign and 600 GSM Mat 188 Supply and fixing of Air Walker Single personSize: L3.75 x W1.25 x H5 Safe Area Size: L6.75 x W4.25 x H8Material specifications:Main Post made of 4 Inch Pipe and other main pipes 1-1/2 inch Pipes. 3 mm thickness pipes (1680 x 515 x 1780 mm) 4 mm pipe Double coat Powder coating, Heavy duty Branded sealed Ball bearing, for long lasting life. Steel Foot rest / Foot Paddle for long lasting life. 189 Supply and fixing of Chest Press - Single PersonSize: L7.5 x W2.5 x H6Safe Area Size: L10.5 x W5.5 x H9Material specifications:Main Post made of 4 Inch Pipe and other main pipes 1-1/2 inch Pipes. 3 mm thickness pipes. Double coated Powder coating, Heavy duty Branded sealed Ball bearing, Steel & foot rest / Foot Paddle for long lasting life 190 Supply and fixing of Leg Press - Dual PersonDimension : L 120cm ( 4ft ) x W 45cm ( 1.5ft ) x H 130cm ( 4.3ft ) Material : Galvanized Steel. Fastners : Stainless steel 304 grade with Polycaped. Post top Cap : High density Aluminium. Handle grips : HD Rubber coated. Twister Base : Polyethylene. Bearing setting for smooth rotation. Main Post Size : 115mm / 4.5 OD G.I post of wall thickness 3mm. Handle Post Size : 32mm / 1.25 OD G.I post of wall thickness 3mm. Powder coating : 80 micron Akzo nobel electrostatic coated. Area Required : Length 180cm ( 6ft ) x Width 180cm ( 6ft )All Metal posts are made of Galvanized pipes with elecrostatic powder coated. 191 Supply and fixing of Push Up / Pull BarSize: L3.5 x W3.5 x H6.5Safe Area Size: L6.5 x W6.5 x H9.5Material specifications:Main Post made of 4 Inch Pipe and other main pipes 1-1/2 inch Pipes. 3 mm thickness pipes Double coat Powder coating, Heavy duty Branded sealed Ball bearing, for long lasting life. Steel Foot rest / Foot Paddle for long lasting life. 192 Supply and fixing of Shoulder Wheel - Single PersonSize: L2 x W2.5 x H6.25Safe Area Size: 4 x 5.5 x 9.25Material specifications:4mm pipe thick Main Post made of 4 Inch Pipe and other main pipes 1-1/2 inch Pipes. 3 mm thickness pipes Double coat Powder coating, Heavy duty Branded sealed Ball bearing, for long lasting life. 193 Supply and fixing of Excer CycleProduct Dimension : L 85cm ( 2.8ft ) x W 83cm ( 2.7ft ) x H 182cm ( 6.1ft ) Material : Galvanized Steel. Fastners : Stainless steel 304 grade with Polycaped. Post top Cap : High density Aluminium. Rotating Knobs : Polyethylene. Bearing setting for smooth rotation. Main Post Size : 115mm / 4.5 OD G.I post of wall thickness 3mm. Handle Post Size : 32mm / 1.25 OD G.I post of wall thickness 3mm. Powder coating : 80 micron Akzo nobel electrostatic coated. Area Required : Length 180cm ( 6ft ) x Width 180cm ( 6ft )All Metal posts are made of Galvanized pipes with elecrostatic powder coated. 194 Supply and fixing of Lat Pull Down - Single personDimension : L 100cm ( 3.3ft ) x W 75cm ( 2.5ft ) x H 180cm ( 6ft ) Material : Galvanized Steel. Fastners : Stainless steel 304 grade with Polycaped. Post top Cap : High density Aluminium. Handle grips : HD Rubber coated. Seat & Back rest : Polyethylene. Bearing setting for smooth rotation. Main Post Size : 115mm / 4.5 OD G.I post of wall thickness 3mm. Handle Post Size : 50mm / 2 OD G.I post of wall thickness 3mm. Powder coating : 80 micron Akzo nobel electrostatic coated. Area Required : Length 180cm ( 6ft ) x Width 180cm ( 6ft )All Metal posts are made of Galvanized pipes with elecrostatic powder coated. 195 Supply and fixing of Sit Up BoardDimension : L 142cm ( 4.7ft ) x W 112cm ( 3.7ft ) x H 63cm ( 2.1ft ) Material : Galvanized Steel. Fastners : Stainless steel 304 grade with Polycaped. Post top Cap : High density Aluminium. Base material : 25mm OD Galvanized Oval pipes. Post Size : 115mm / 4.5 OD G.I post of wall thickness 3mm. Post Size : 45mm / 1.5 OD G.I post of wall thickness 3mm. Powder coating : 80 micron Akzo nobel electrostatic coated. Area Required : Length 240cm ( 8ft ) x Width 240cm ( 8ft )All Metal posts are made of Galvanized pipes with elecrostatic powder coated. 196 KIOSK 197 ACP KioskSupply of Kiosk: MS Tube Frame Covered with ACP Panel Size: 3m x 2m Bottom: Bison Board 1” Thick Front: Large Door with Double Piston Left Side: Access Window Right Side: Main Door With Lock Top: ACP Sheet (Puff Panel) Table: 7.5Ft x 1.5’ Width 1no Accessories: Fan 1No, Tube light 2Nos, Switch Box 1No, MCP 1No, Exhaust Fan 1No, Wash Basin 1No, Vinyl Flooring, LED Name Board with Logo, Menu Card 198 ELECTRICAL WORKS 199 LT CT TNEB METER BOX: Supply, Installation, testing and commissioning of compartmentalised LT 3Phase, TNEB Metering box of outdoor weather proof type with MS mounting stand, Test Terminal Blocks, Internal control wiring etc., as per local TNEB standards. The box suitable for 3phase 100A service connection made up of with hylem sheet of size 2feet x 1-1/2feet of 6mm thickness with necessary bolts and nuts supports and supply and fixing of3Nos.100A fuse units (500V),1No.neutral link,copper earth flat of size1x1/4 with interconnection of EB meter tofuse units by 16 Sq.mm PVC insulated copper wire with suitable necessary connection with earth connection complete. 200 Supply and fixing of 125A TPN Isolator in sheet steel enclosure with double breakon suitable angle iron frame work with MS cable entry boxes with earth connection only. 201 MAIN LT PANEL: Supply, Installation, testing and commissioning of 3Phase, 415Volts, Main LT Panel board of Indoor, Cubicle floor mounting type made out of 2mm thick CRCA Sheet with powder coated finishing, MS base frame, double internal earthing arrangements, 125Amps, rating TPN Copper busbars with interconnection busbar, etc., comprising of the followings:EB Incomer :1 No. 125Amps, 25kA, 4Pole, Thermal magnetic MCCB with Ext.RHOMMetering : 1 Set of RYB LED Indication lamps1 No. of Multifunction Meter with RS 4851 Set of Current Tranformers (125/5A, Cl-1), 1 No. 125/5A CT for APFCR1 Set of Control MCBs Outgoings: 7 Nos. 63Amps, TP+N MCCB 2 Nos. 32Amps, TP+N MCCB3 Nos. 25Amps, DP MCB[Size:2400mm (L) x 350mm (D) x 2000mm(H)] 202 APFCR PANEL - 25KVAR: Supply, Installation, testing and commissioning of 3Phase, 415Volts, 25KVAR rating APFCR (Capacitor) Panel board of Indoor, Cubicle floor / wall mounting type made out of 2mm thick CRCA Sheet with powder coated finishing, MS base /wall frame, double internal earthing arrangements, 63Amps, rating TPN Copper busbars with interconnection busbar, etc., (1 x 10KVAR + 2 x 5KVAR + 1 x 3KVAR + 1 x 2KVAR) 203 12WAY Outdoor Lighting DB - 1 to 5: Supply, Installation, testing and commissioning of Outdoor weather proof type 3Phase Outdoor Lighting DB comprising of 1 No. 63Amps, TP+N, MCCB with Extended RHOM as incomer with RYB LED Phase indication lamps, 3Phase 63Amps, 4Pole Timer internal control wiring, etc., Outgoings: 11 Nos. 16A-32Amps, 4P MCBs &3 Nos. 20Amps, DP MCBs including Copper busbar connections, interconnection cables, cable entry provisions, floor mounting frame (600mm to 900mm), etc., 204 SLDB-1 to 4 and ELV UPS DB: Supply and fixing of 12 way single pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1no. 32A DP MCBswitch as incoming and 10 nos. 6A to 32A SP MCB as outgoing in flush with wallwith earth connection only.Higher End 205 Pump room DB - 1 & 2: Supply and fixing of 8 way Vertical Triple pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1 no. 63A 4P MCB switch as incoming and 5 nos. 32A 3P MCB, 9 nos. 6A to 32A SP MCB as outgoing on wall with earth connection only. Higher End 206 SupplyandLayingof31/2 Corex120 sq.mm.PVCarmouredLTUGcablein suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good. 207 SupplyandLayingof31/2 Corex70 sq.mm.PVCarmouredLTUGcablein suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good 208 SupplyandLayingof31/2 Corex50 sq.mm.PVCarmouredLTUGcablein suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good. 209 SupplyandLayingof31/2 Corex95 sq.mm.PVCarmouredLTUGcablein suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good. 210 SupplyandLayingof31/2 Corex25 sq.mm.PVCarmouredLTUGcablein suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good. 211 Supply and Clamping of 2 core x 10 Sq.mm PVC armoured LTUGaluminium cable on post or on wall MS-clamps, saddles, plugs, screws etc., complete including transport charges of UG cable. 212 Supply and fixing of brass cable gland for 2 x 10 sq.mm. PVC armoured LTUG cable with earth connection 213 Supply and fixing of brass cable gland for 3-1/2 x 25 sq.mm. PVC armoured LTUG cable with earth connection 214 Supply and providing cable end termination of 3-1/2 x 25 sq.mm. PVC LTUG aluminium armoured cable with necessary aluminium cable sockets by crimping etc with electrical connection complete 215 Supply and fixing of brass cable gland for 3-1/2 x 50 sq.mm. PVC armoured LTUG cable with earth connection 216 Supply and providing cable end termination of 3-1/2 x 50 sq.mm. PVC LTUG aluminium armoured cable with necessary aluminium cable sockets by crimping etc with electrical connection complete 217 Supply and fixing of brass cable gland for 3-1/2 x 70 sq.mm. PVC armoured LTUG cable with earth connection 218 Supply and providing cable end termination of 3-1/2 x 70 sq.mm. PVC LTUG aluminium armoured cable with necessary aluminium cable sockets by crimping etc with electrical connection complete 219 Supply and fixing of brass cable gland for 3-1/2 x 95 sq.mm. PVC armoured LTUG cable with earth connection 220 Supply and providing cable end termination of 3-1/2 x 95 sq.mm. PVC LTUG aluminium armoured cable with necessary aluminium cable sockets by crimping etc with electrical connection complete 221 Supply and fixing of brass cable gland for 3-1/2 x 120 sq.mm. PVC armoured LTUG cable with earth connection 222 Supply and providing cable end termination of 3-1/2 x 120 sq.mm. PVC LTUG aluminium armoured cable with necessary aluminium cable sockets by crimping etc with electrical connection complete 223 Supply and erection of GIHotDip/PowderCoated16SWGPerforated type CableTraywith 300mm width and 50mm height with all the fixing accessories 224 Supply and Run of 2 of 2.5 sq.mm.PVC insulated SC unsheathed FRLS copper conductor of 1100 V grade in suitable gauge MS conduit pipe Concealed inwall and ceiling with continuous earth wire connection of 2.5 sq mm copperwire and making good of the concealed portion 225 Supply and Run of 2 of 6 sq.mm.PVC insulated SC unsheathed FRLS copper conductor of 1100 V grade in suitable gauge MS conduit pipe concealed inwall and ceiling with continuous earth wire connection of 6 sq mm copperwire with painting of suitable colour. 226 Supply andrunof2 of4 sq.mm. PVC insulatedSC unsheathedFRLS copperconductorof1100V gradeinsuitable heavy gauge MS conduit pipe concealed in wall and ceiling with continuous earth wire connection by 4 sq.mm copper wire and making good of the concealed portion wiith suitable colour 227 Supply and fixing of 1 no.6A two module 5 pin socket , 1 no.6A one module switch with module cover plate (plastic) onsuitable module concealedBox (GI ) in flush with wall with connections. Higher End 228 Supply and fixing of 2nos.6A two module 5 pin socket , 2 nos.6A one module switch with module cover plate (plastic) onsuitable module concealedBox (GI ) in flush with wall with connections. Higher End 229 Supply and fixing of 1 no.6/16A two modulesocket , 1 no.16A one module switch with module cover plate (plastic) onsuitable module concealedBox (GI ) in flush with wall with connections. Higher End 230 Wiring with 2 x1.5 sq.mm. PVC insulated single core unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with PVC accessories with Module GI switch box in flush with wall with 6A one way module switch with module front plate with continuous earth wire connection of 1.5 sq.mm copper wire and making good of the concealed portion with suitable colour for Concealed PVC Light point / fan point (for electronic regulator) (6 points / Coil) Higher End (Primary) 231 Supply and fixing of 18W LEDRound type Recessedfitting with LED (Higher end) on false Ceiling from ceilingwith PVC unsheathed copper leads from terminals to the fitting. 232 Supply and erection of 20Watts, 4 Feet LED Fitting with LED (Higher end) end cap, PVC unsheathed copper leads from terminals to the fitting and fixing accessories 233 Supply and fixing of 60Watts All-in-One (AIO) Model Solar Street Light with 6000mm Height pole with base plate and all the fixing accessoriesThe cost is inclusive of civil foundation works including anchor fasteners,etc., as per site requirements 234 Supply and fixing of 3W RGB Light fitting (IP67) Inground fixture with PVC unsheathed copper leads from terminals to the fitting and to complete necessary accessories and etc to complete the work. KLITE:4092 - symmetrical Inground 235 Supply and fixing of spike light 6W fitting on floor with PVC unsheathed copper leads from terminals to the fitting and to complete necessary accessories and etc to complete the work. KL-Trioscope - 7052 236 Supply of One No of 9.5 mtr. Street Lamp Post With 2.7 mtr Arch Double Bracket, 1 No. of 4 Core SMC Fuse Box With Hot Dip Zinc Galvanising 237 Cost of Erection & Materials Required For 9.5 mtr Street Lamp Pole With Brackets Conventional Foundation(Material Ratio - 1:1.5:3) 238 Supply and fixing of 300mm (12) sweep(Heavy Duty) AC exhaust fan complete with necessary wall opening and making good of the wall . 239 Supply and fixing of MS / Fibre Louvers Shutters arrangements for 300mm ACExhaust Fan (M-1346) 240 Supply and fixing of 1200mm (48) sweep AC ceiling fan 5 star ratedcomplete ( Higher end)with 2 module 100W fan step regulator (Higher end)with 1 metre down rod with fan clamp with side plates and cross arm of size 450mm (18) 241 Supply and fixing of Maintenance Free earthing with Copper rod of 17.2 mm dia and 3m length including all the civil works 242 Supply and run of 25mm x 3mm tinned copper flat with necessary clamps / supports on wall / floor / ground for earth connection 243 Supply and Run of1 of No.8 SWG copper wire for earth connection 244 Supply and Run of1 of No.8 SWG copper wire in suitable PVC rigid pipeon wall / floor / ground for earth connection 245 Supply of 2mx1mRubberMatsuitablefor11KVinstallation confirming to IS 246 Supply of First Aid Box complete with all First Aid Medicines 247 Supply and fixing of Shock Treatment chart with Glass frame(in English & Local Language) 248 Supply and fixing ofMetallic Danger Board as required by the Electrical Authorities (415Volts & 230Volts) 249 Supply and Installation for 2KVA, UPS (Single Phase Input & Single Phase Output) Capacity with 2Hourse Battery back up, battery stand and interconenction cables. 250 Supply and fixing of 40Amps, 30mA DP RCCB in a suitable sheet steel enclosure and necessary fixing accessories (Higher end) 251 CCTV SYSTEM 252 Supply, Installation, Testing and commissioning of 32 channel 8 SATA NVR, with 10TB Hard Disk Drive 2 nos, New logical and visualized GUI design Dual-OS design to ensure high reliability of system running, ANR technology to enhance the storage reliability when the network is disconnected,Configurable normal or hot spare working mode to constitute an N+1 hot spare system Video Input and Transmission, Connectable to the third-party network cameras Compression and Recording, H.265+ compression effectively reduces the storage space by upto 75%, Full channel recording at up to 12MP resolution HD Video Output  HDMI1 / VGA1 outputs provided  HDMI1 Video output at up to 4K ( 3840 × 2160 ) resolution Storage and Playback, Upto 16 SATA interfaces and 1 eSATA interface for HDD connection, Support upto 10TB capacity for each HDD, Smart search for efficient playback. and smart playback to improve the playback efficiency, Supports VCA search for fire/ship/temperature/temperature difference detection triggered video files, POS information overlay on live view and playback, POS triggered recording and alarm Network & Ethernet Access  Hik-Connect for easy network management, 2 Gigabit Ethernet network interfaces. 253 Supply of 4MP, Internet Protocol fixed BULLET CAMERA (OUTDOOR) with following specification:a) 1/2.5 Progressive Scan CMOS, b) 3840 × 2160 @15 fps,2.8/4 mm fixed lens,01 lux @ (F1.2, AGC ON), 0.028 lux @(F2.0, AGC ON), 0 lux with IR, H.265+, H.265, H.264+, H.264, 2 Behavior analyses ( Line crossing detection, intrusion detection)c) Face Detection d) 120dB WDR, e) BLC/3D DNR/ROI, IP67 compliedff) On-board Storage -Built-in micro SD/SDHC/SDXC card slot, up to 128 GB,g) Shutter Speed 1/3 s to 1/100,000 s, h) 3-Axis Adjustment Pan: 0° to 360°, tilt: 0° to 100°, i) rotate: 0° to 360°, 2.8 mm, j) horizontal FOV: 102°, vertical FOV: 53°, diagonal FOV: 124°, k) Lens Mount M12 & IR Range I5: up to 50 m, l) Image Settings Rotate mode, saturation, brightness, contrast, sharpness adjustable by client software or web browser, m) Power Consumption and Current-12 VDC, 0.7 A, max. 7.5W PoE: (802.3af, 36V to 57V), 0.3 A to 0.2 A, max. 9Wn) Camera out fitted with metal housing so as to prevent the lens from damages during physical abuse. with Camera Stand. 254 Supply of 8MP, Internet Protocol fixed BULLET CAMERA with following specification:●1/2.5 Progressive Scan CMOS, ● 3840 × 2160 @15 fps,2.8/4 mm fixed lens,01 lux @ (F1.2, AGC ON), 0.028 lux @(F2.0, AGC ON), 0 lux with IR, H.265+, H.265, H.264+, H.264, 2 Behavior analyses ( Line crossing detection, intrusion detection)● Face Detection ● 120dB WDR, ● BLC/3D DNR/ROI, IP67 complied●On-board Storage -Built-in micro SD/SDHC/SDXC card slot, up to 128 GB,● Shutter Speed 1/3 s to 1/100,000 s, ● 3-Axis Adjustment Pan: 0° to 360°, tilt: 0° to 100°, ● rotate: 0° to 360°, 2.8 mm, ● horizontal FOV: 102°, vertical FOV: 53°, diagonal FOV: 124°, ●Lens Mount M12 ● IR Range I5: up to 50 m, ● Image Settings Rotate mode, saturation, brightness, contrast, sharpness adjustable by client software or web browser, ● Power Consumption and Current-12 VDC, 0.7 A, max. 7.5W PoE: (802.3af, 36V to 57V), 0.3 A to 0.2 A, max. 9W● Camera out fitted with metal housing so as to prevent the lens from damages during physical abuse with suitable Stand. 255 Supply, Installation, Testing and Commissioning of 55 smart LED TV with following specifications a) Resolution: Ultra HD (4K) 3840 x 2160b) IPS panel c) Slim back light LED module d) 900 PMI e) Triple XD engine f) Dynamic scanning g) ANRh) True colour generatori) 8modes of picture j) picture wizardIII k) Real cinema 24P l) HDMI -3nos m) USB -2nos n) Built in LAN o) Magic remote 256 Supply and Clamping of CAT 6 unarmoured cable in suitable PVCPipe 1 thick on wall / ceiling with connected PVC accessories with clamps, saddles etc., complete. (Between ethernet switch to camera and radio modem)i. Application : Primary (Campus), Secondary (Riser), Tertiary(Horizontal)IEEE 802.3 : 10Base-T; 100Base-T; 1000Base-TIEEE 802.5 16 MB; ISDN; TPDDI; ATMii. Standards: ISO/IEC 11801 2nd ed.; IEC 61156-5 2nd EN 50173-1; EN 50288-6-1,EIA/TIA 568C.2, RoHS Compliant.Fire Rating: PVC : IEC 60332-1.iii. Conductor - Bare Copper Wireiv. Insulation - Polyethylene v. Twisting - 2 Cores to the pair vi. Cable lay up - 4 Core to the pair It has diameter of (23 AWG) 0.550 ± 0.015.Insulation : Polyethylene.GI wire of size is 0.90 ± 0.030mm. 257 Supply and laying of armoured, Multimode, Thermoplastic Tape Inner Sheathed, PVC type sheathed 6 core Optical Fibre Cable withunique fiber excess length control method provides the cable with excellent mechanical and environmental properties and Cable - 2 Embedded FRP provides tensile strength & Anti-buckling properties. It is processed with Filling jelly - Thixotropic jelly to prevent Water ingress in loose tube. 258 Supply and Termination of Optical Fibre Cable Single Point ( Point to Point ) Splicing and arrangement charges. 259 Supply and fixing of POE 8port switch10/ 100 / 1000 Base -T / 2 x 1000Base-FX / 20Gbps bandwidth / IEEE803.af/at compliant PoE+ / RJ45 supports auto MDI/MDI-X function / Auto negotiation speed, half/full-duplex / Store and forward / Max packet size: 10kbytes / Wide range power design (12~56VDC) / Operating temperature (-40 ̊C ~ +75 ̊C) / Reverse polarity protection / Resettable fuse to protect against overcurrent / IP-40 protection / EFT protection for power line. 260 Supply and Fixing of Rack with Accessories -Higher end6U Rack with fan extra for the above rack. (speaker/data/cctv) 261 Supply and fixing of POE 24 port switch10/ 100 / 1000 Base -T / 2 x 1000Base-FX / 20Gbps bandwidth / IEEE803.af/at compliant PoE+ / RJ45 supports auto MDI/MDI-X function / Auto negotiation speed, half/full-duplex / Store and forward / Max packet size: 10kbytes / Wide range power design (12~56VDC) / Operating temperature (-40 ̊C ~ +75 ̊C) / Reverse polarity protection / Resettable fuse to protect against overcurrent / IP-40 protection / EFT protection for power line. 262 Supply, Fixing and Termination of CAT 6 Cable RJ 45Jack Single Point ( Point to Point ) Crimping, Testing and arrangement charges. 263 Supply and fixing of outdoor 4X6PVC box with 102mmX77mmX102mm with all fixing accessories. 264 Supply and Erection of 6mtrLengthpole with base plate of size 300x300x12mm as per IS-875 with following specification. Pole Outter dia -76.10mm x 3.65mm Thick x 6 meter with foundation Charges.The Pole Should be hot dip Galvanized confirming to BESN ISO-1461 with thickness of 65 Micron 265 PA SYSTEM 266 Supply, Installation,Testing & commisioning of 30 watts 2 way high efficiency, high fidelity, long throw IP65 weather proof P.A Music Horn WALL / COLUMN speaker. It combines the high efficiency of horn with wide frequency response.Music horn is weather protected and UV protected ABS plastic housing combines with the feature of easy poertap selection on a terminal strip with a two core cable.It has impedence of 250/500/1k/2k ohm with frequency response of 120-16000 hertz. 267 Supply, Installation,Testing & commisioning of 480 watts P.A Booster Amplifier with the output power of 1350 watts maximum, 500watt rms at 10% Thyristor harmonic distortion(THD), 850watt RMS at 5% THD, 800 wattsRMS at 2% THD and the power supply AC voltage ranging from 220-240 volt, 50/60 hertz. with the DC input of 48 volt and 1000watts has tone controls of Bass=+- 10 db at 100 hz weighing 42kg with the speaker output of2Q,4Q.70volt&100volt has power consumption of 1600VA AC &12A DC and 100db output regulation at 1khz no load to full load ratio. The signal to noise ratio is 60db with the imnput channels of 0.8mv/4.7kq,3*Aux 100mv/50kq.The frequency response of 50-15000hz+-3db. 268 Supply, Erection,testing & Commisioning of custom built table top 4 zone micro processor based 1 way announcement console cinsisting of teleline preamplifier , 1 x priority module , 12 zone selector module , all call switch module , tone oscilator modulefor fire evacation, press to talk switch module,goose neck microphone ,24v dc rectifier module, power supply uit , all call relay module etc as required.(Delegate unit) 269 Supply and Fixing of Rack with Accessories -Higher end6U Rack with fan extra for the above rack. (speaker/data/cctv) 270 Supply, run, testing and commissioning of2Core x 1.5sq sqmm PVC insulated Armoured Speaker Cable in suitable 25mm dia Pvc Rigid pipe concealed on wall and ceiling with continuous earth wire connection with painting of suitable colour.
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 3
37.
Housing Urban and Rular Development #10200585 Price Bid
Tender For Construction Of New Muthalvar Padaippagam At Bhakthavachalam Park, Chennai; 1 Civil Works 2 Dismantling removing the existing Reinforced Cement Concrete work etc., by using required mechinaries includingdisposal of unserviceable material, labour charges, as per direction of Engineer in charge. 3 Dismantling removing the existing Brick work etc., by using required mechinaries includingdisposal of unserviceable material, labour charges, as per direction of Engineer in charge. 4 Removing the existing ventilators,doors and windows including removal of frames ,hinges and fastenings arefully and stacking the same at site etc., complete. 5 Dismantling Floor finish and daddoing walls in cement mortar with mosaic tiles/glazed tiles/cuddapah slabs. 6 Carting away the surplus earth and debris to a lead of 5kgm.including Loading, unloading and dumping in the Corporation Land as directed during the execution. 7 Dismantling removing the existing closet, fitting, pipes, etc as per site., by using required mechinaries includingdisposal of unserviceable material, labour charges, as per direction of Engineer in charge. 8 Civil Works 9 Providing and constructing cast in situ hydraulic bored piles of specified diameter in M30 grade concrete using blended cement - slag cement with minimum cement content of 400kg/m³in accordance with the structural engineers drawings and directions, but exculding reinforcement including cost of mobalization of all necessary plants, equipments like piling rigs, temporary casing of appropriate length forsetting out cardinal points and the removal of the same, boring in overburden, using bentonite mud circulation technique or any other method dulythrough all strata upto the foundation level of piles etc., complete all as approved by the departmental engineer. Further include dewatering, placing concrete by tremie pipe method, disposal of bored material outside the site. Including Chipping carefully cut off portion of piles as required without any damage to the piles and dressing the top and removing all the debris away from the site with out any extra cost as directed including the cost of all tools, plants, conveyance, all labour, lead and lift required etc .,Conducting standard penetration test to identify the refusal strata for atleast 1 pile in group and atleast 25% of piles, comparing with refusal strata as indentified in soil report and providing socketting into refusal strata by 1.00mt or into hard rock by 100% dia of the pile. (Length of pile for payment shall be measured up to bottom of pile cap). 10 Boring or chiselling through any obstacles, boulders, weathered rock, etc. Upto founding level of piles for seating resting or socketting of files. The rate quoted shall include demobilising the site with all plants, equipment, piling rigs, necessary personnel brought for piling work, including removal and transportation of debrise away as directed, cleaning and reinstating site to original condition as acceptable by the Architect on completion of piling work. 11 450 mm Dia 12 Carrying out initial working pile load test on specified dia piles as specified in IS:291 1 (Part 4). Includes all plant, equipment, machinery. Instruments, measuring devices, platforms and kentledge pile caps etc., dismantling and carting away entire setup, excavation and dewatering etc., all complete 13 Earth work excavation for all foundations in all type of soils and sub soils to the required depth for Footings, plinth / grade beams, etc,. by mechinaries including manual excavation for the following type of soil / rock as per detailed specification. As per SS 20B as hard rock requiring blasting inclusive of shoring strutting and baling out water wherever necessary and including refilling 0 to 2.0m depth consolidation depositing the surplus earth in places shown clearing and leveling the site with an initial lead of 10 metre and lifts as specified hereunder etc., complete in all respects complying with relevant standard specification and as directed by the departmental officers. 14 Supplying and filling of Gravel / Good Earth by lorry in Foundation basement filling and site filling with approved materials excavation from approved quarries and compacted to meet requirement of table 300-1, 300-2 of MORTH, in layers not exceeding 300 mm loose thickness, spreading, breaking clods, removal of roots and other organic materials to the required line, grade and cross-section including watering, spreading by Dozer, grading by motor grader and consolidation by vibratory road roller with desired field density not less than 95% of maximum dry density ,including all lead,lift, loading, unloading, all labour, hire charges of all machineries, Transportation, etc., complete in accordance with MORTH technical specification clause No. 305 and with all other incidental charges and as per the direction of the Engineer-In-Charge. 15 Providing Pre construction Anti termite treatment for the building including all chemicals as per standard specifications. Labour charges for preparing the areas for treatment spraying chemicals and other incidential charges etc., complete. The rate shall be inclusive ofgiving anti-termite treatment to the building for the following four stages including breaking the termite mounds making holes with crow bars at an intervel of 12to a depth of 8 in the periphery of building and pouring chemicals etc., complete as per ISI 6313-1981 and. The antitermite chemicals used should have 0.5% concentration with 3L solution for the entire operation etc. as directed by the Engineer incharge and including cost of chemicals labour transportion etc., 16 Stage:1 Spraying Anti-termite treatement chemicals solution for the foundation before laying the foundation concrete bottom and sides of the foundation. 17 Stage:2 Spraying anti-termite chemicals solution to the grade beams level spraying has to be done for the grade beams brick masonry in the superstructure in contact with back fill earth. 18 Stage:3 Spraying anti-termite chemicals solution on sand for the flooring before laying the flooring concrete. The treatment has to be carried out on the sand filling the basement after leveling operation is over. 19 Stage:4 Spraying anti-termite chemicals solution around the building outside of the building by making crow bar holes at an intervel of 12 to a depth of 8 around the building before laying the plinth projection.This holes has to be be closed after the treatment. 20 Supplying and Filling withM-sand in floor and others sub structures for 150mm thick and well watered, rammed and consolidated by power compacter. The rate includes the cost of river sand, compacting with mechanical compactors, labour charges for leveling, loading & Unloading and Transportation charges etc., complete and as per the standard specification. 21 Construction of Wet Mix Macadam 150mm compacted thickness in two layers by providing , laying , Paving , and compactingofaggregate gradation satisfying to Table 400-13 of MORTH and satisfying the physical paraeteres as per MORTH Table 400-12, mixing in a Wet Mix Plant of 200 tonne capacity at OMC , carriage of mied material to work site and laid in sensorpavers to the required line and grade as per the drawing and compacted with vibratory roller of 8-10 tonne to achieve the desired density of 98% of Maximum dry density and as per the direction of the Engineer-In-Charge of work. 22 Providing and laying plain cement concrete 1 : 4 : 8 ratio of(1 cement , 4 sand and8 graded stone aggregate 40mm nominal size) in foundation and basement for 100mm thick including dewatering wherever necessary and consolidation etc. The rate includes the cost of materials, labour charges, lifting charges, loading & Unloading and Transportation etc., complete and as per the standard specification. 23 Supplying and erecting centering for sides and soffits including supports and strutting up to 3.30 m height with all cross bracing for plane surfaces as detailed below, using mild steel sheets of 90 X 60 cm 10 gauge stiffened with MS angle of 25 X 25 X 3mm for boarding, laid over adjustable span & jacks and supported by 50mm dia pipes for general pipes scaffolding systems @ a spacing of 1.20m c/c and vertical connected at a height of 2.0m c/c including C & U clamps and base receiver cup at bottom for connecting pipes etc and removable systems etc., the rate including cost of all materials, labour charges, wastages, placing, transportation, lead & lifts, tools & plants, fuels, fixing in position at all levels, heights, masking tape in sheet joints, consumables, etc. as complete with all respects complying with relevant standard specification, as directed by the Engineer-in-charge. 24 For column footing plinth beam , pile cap staircase steps, piers raft beam raft slab etc., 25 For Plain surfaces such as RCC slab, Beam, Bed Block, waist slab, landing slab, lintel etc., 26 For square or rectangular column, boxing, sunshade etc., 27 Providing and Laying M 30 Standardised concrete Mix for all reinforced cement concrete with minimum cement content conform to IS 456-2000 using ordinary Portland cement of grade 53 from approved manufacturer, manufactured sand, 20 mm and down graded size coarse aggregates, necessary approved admixtures as per requirement. works for Footings, Grade beam, retainning wall drain wall & raft , Plinth beams, Column, Grade slab, Roof slab & beam, Column drops, Pergola, Staircase waist and landing slab lintel, Sunshades, parapet Cum drops, Steps, canopy, window boxing slab, Loft, fins facia Planter box, machine foundation, elevation features and other similar structures etc..excluding necessary centering, shuttering and reinforcement which shall be measured and paid separately under relevant items. in-charge The rate including cost of all designing the mix, batching plant, mechanical mixing, transporting and placing at all levels, leads, lifts, tools & plants, fuels, all materials, labour charges, wastages , laying, pumping the concrete to all levels, providing sleeves / openings in RCC slabs, compaction by vibrator, gunny bags for curing etc. as complete with all respects complying with relevant standard specification, as directed by theEngineer-in-charge 28 Basement 29 GF 30 FF 31 Terrace 32 Supplying, fabricating and fixing in position of steelFe 550 grade Reinforcement for all RCC work with Thermo Mechanically Treated Bars (TMT) conforming to IS 1786 of latest version according to drawings and binding the reinforcement with 18 gauge double fold GI binding wire and providing Concrete cover blocks to maintain the cover as required. The rate including cost of all materials, bending, tying grills, placing, transportation, lead & lifts, tools & plants, fuels, all materials, labour charges, wastages , laying at all levels, fixing in position, cost of cover blocks and GI binding wires etc. as complete with all respects complying with relevant standard specification, as directed by the Engineer-in-charge. 33 Brick work in cement mortar 1:6(one cement and four sand) using fly ash bricks of size 230mmx110mmx70mm for foundation and super structure as per detailed specifications and as directed by the departmental officers 34 Ground Floor 35 First Floor 36 Terrace 37 Brick partition walls of 11.50cm thickness using best quality Fly ashbricks of size 9 x 4-3/8 x 2-3/4(230x115x76) in Cement Mortar 1:3 (One Cement and Three Sand) using hoop iron reinforcement if found necessary including curing etc. complete and as directed by the departmental officers. (Hoop iron reinforcement will be measured and paid for separately) 38 Plastering 10 mm thick for ceiling including slabs, beams and column drops and staircase waist slab, sunshade, drops, chajjas etc.. with cement Mortar 1:3 (1 of Cement : 3 ofP sand) according to the specification. The Rate including Cost of all materials, labour charges, wastages, necessary lead and lifts, working at all levels, transportaion charges, loading, unloading, preparation of surface, ncessary haccking in RCC surface, scaffolding, stagging, providing drip bands, moulds to any size and shape as shown in drawings tools and plants, fuel, curing,cleaning, consumables etc as complete with all respects complying with relevant standard specification and as directed by the Engineer-in-charge. 39 Plastering of 12 mm thick for Internal walls with cement mortar 1:4 (1 of cement : 4 of fine P.sand)according to specifications. Rate shall include for providing GI mesh of nominal thickness at the junctions of masonry and concrete works to a width of 100 to 125mm including tying in position with suitable clamps/screws. Rate including all materials, labour charges, wastages with necessary lead and lifts, working at all levels, transportaion charges, loading, unloading, preparation of surface, ncessary haccking in RCC surface, scaffolding, stagging, tools and plants, fuel, curing,cleaning, consumables etc as complete with all respects complying with relevant standard specification and as directed by the Engineer-in-charge. 40 Plastering 12 mm thick for external surfaces with cement mortar 1:4 ratio (1 of cement : 4 of fine P.sand) including water proofing compound of “CICO No.1 or equivalent“ as per Manufacturers Specification with sponge finish (washed sand finish) all complete as per specification and as directed.Rate including all materials, labour charges, wastages, necessary lead and lifts, working at all levels, transportaion charges, loading, unloading, preparation of surface, ncessary haccking in RCC surface, scaffolding, stagging, providing drip bands, moulds, grooves to any size and shape as shown in drawings tools and plants, fuel, curing,cleaning, consumables etc as complete with all respects complying with relevant standard specification and as directed by theEngineer-in-charge. 41 Supply and painting oftwo coats of Plastic emulsion paint of approved shade and colour over one coat of DCP Primer including one coat of Acrylic Wall Putty with DCP Primer.Rate including all brush, roller, ladder, scrapping, washing, materials, labour charges, wastages , cleaning, necessary lead and lifts, scaffolding, stagging, working at all levels, elevations,transportaion charges, loading, unloading, curing, sanding, touchup putty, surface thoroughly cleaned and wetted before painting as complete with all respects complying with relevant standard specification and as directed by theClient / Engineer-in-charge.(Internal surface) 42 Supplying and painting of2 coats of weather proof exterior emulsion with high sheen, anti algal properties over one coat wall exterior primer of approved quality and shade etc., complete.Rate including all brush, ladder, scrapping, washing, materials, labour charges, wastages , cleaning, necessary lead and lifts, scaffolding, stagging, working at all levels, elevations,transportaion charges, loading, unloading, curing, sanding, touchup putty, surface thoroughly cleaned and wetted before painting as complete with all respects complying with relevant standard specification and as directed by the Engineer-in-charge. 43 Manufacturing, Supplying and Fixing of Stainless Steel Hand rails for staircase using 50mm dia 304L Grade Stainless Steel pipe of 1.60mm thick at required locations to a height of 900mm from finished floor level welded to 38mm dia Stainless Steel pipe post of 1.00mm thick as vertical at 900mm centre with 2 Nos. of 25mm dia intermediate horizontal stainless steel pipe of 1.60mm thick in between. The vertical pipe has to be welded to the 100 X 100 X 6mm MS base plate encased in the base concrete. The rate is inclusive of the charges for cutting, bending, welding, grinding, polishing, conveyance, electrical charges, etc. complete (M-0652) 44 Supplying and filling the sunken slabarea byBRICK-BATCOBA by adding CICO NO:1 or approved equivalent admixture including applying two coats not less than 2 mm thick of TAPECRETE- AcrylicPolymer Based Waterproof Coating, over the final coat of cement plaster 12 mm thick with cement sand mortar 1:3 mixed with water proofing compound like CICO No.1 at the rate specified in the manufacturers specification after entire completion of laying pipes, sanitary fittings etc.Rate including all materials, labour charges, wastages with necessary lead and lifts, working at all levels, protecting the laid pipes and sanitary fittings, finishing the surface smooth to receive the top coat of water proofing application etc. as complete with all respects complying with relevant standard specification and as directed by theClient / Engineer-in-charge. 45 i) Includingapplying two coats not less than 2 mm thick of TAPECRETE- AcrylicPolymer Based Waterproof Coating, over the plastered surface as including final coat of cement plaster 12 mm thick with cement sand mortar 1:3 mixed with approved water proofing compound like CICO No.1 or approved equivalent conforming to IS 2645 at the rate specified by the manufacturer over coated surfacepreparation of surface, finishing, curing etc. all complete at all levels as per manufacturers specifications and as directed. 46 Supplying and laying of Ceramic tiles of size 305 x 305 x 6mm for flooring approved make and quality with plain/colourwith base mortor in CM 1:3, 10mm thick and pointing with white cement by adding suitable colour pigments including finishing, jointing and polishing with neat finish etc., complete. The rate including cost of all materials, labour charges, wastages, necessary lead and lifts, working at all levels, transportaion charges, loading, unloading,the same before handing over as complete with all respects complying with relevant standard specification and as directed by the Engineer-in-charge. 47 Supplying and fixing Dadooing the wall with ceramic tiles of approved quality, colour and design joint free of size 600x300x10mm thick of approved make, in all floors over a base layer of cement mortar 1:2 (one cement: Two sand) 10mm thick and laid straight alignment and pointed neatly with colour cement at the rate of 0.40 kg/m2 laid without any air gap in the tiles neatly and fixing in position as per standard specifications. The rate including cost of all materials, labour charges, wastages, necessary lead and lifts, working at all levels, transportaion charges, loading, unloading,the same before handing over as complete with all respects complying with relevant standard specification and as directed by the Engineer-in-charge. 48 Providing and laying factory-manufactured linoleum flooring in the form of Rolls in the size of 12192mm of length and 1981mm of wide with 2mm thickness which laying above in the vertified tiles using the adhesive the flooring shall be laid over a smooth, level subfloor using manufacturer-recommended adhesives, complete in all respectsRoll flooring shall be laid with butt joints; edges shall be cold-welded or heat-welded for seamless joints.Apply a coat of linoleum polish or sealant after laying (if uncoated variant is used). Proper rolling to remove air pockets and ensure bonding the rate is inclusive of all necessary material, labour, transportation etc asper standards. 49 Finshing the top of roof with one course of machine pressed tiles of size 230mm x 230mm x 20mm of approved quality set in cement Mortar 1:3 (one cement and threee sand ) 12mm thick mixed with water proofing compound conforming ti ISS at 2% by weight of cement used and the joints pointed neatly to full depth of tiles with the same cement mortar mixed withred oxide and water proofing compound including curing et,. complete complying with standard specification and as directed by the departmental officers 50 Providing Polymer Coating (Water Proof Coating) for sunken portion of toilet with following specification and the surface shall be cleaned to remove all dust, foregin, matters lose materials or any other deposits of contamination by rubbing with wire brush. Slurry: Dry blend and polymer liquid blend shall be mixed into the desired ratio as per recommendation of the supplier. The mix shall be stirred thoroughly until no bubbles remain in the mix. Any lumps found in mix shall be removed. Apply first coat of polymer modified cementitious slurry by brush on wet cleaned surface. After drying, second coat shall be applied on the first coat as directed by the departmental officers etc. The rate inclusive of cost of materials and labour, etc., complete. 51 Supply and laying with best quality the following materials of Machine Polished granite slab not less than 18 mm thick (Jet Balck) including cutting for wash basin and edge polishing to be set in CM 1:4 (1 of cement : 4 of manufactured sand) 20 mm thick including finishing the joints with white cement slurry, cutting, edge chamfering to approved shape and polishing rough, medium, nice and tin-oxide polish. The rate including cost of all materials, labour charges, wastages, necessary lead and lifts working at all levels, transportaion charges, loading & unloading, preparation of surface, ncessary haccking in RCC surface, cutting to required shape, edging, tools and plants, fuel, curing,cleaning, acid wash over finished surface, protection with Gypsum / Poplayeroverplastic sheet and removing the same before handing over as complete with all respects complying with relevant standard specification and as directed by the Engineer-in-charge 52 Supplying and fixing plywood partition with Teakwood frames of75x50mm size and with 3mm thick commercial plywood fixedwith screws and nails including fixing in position with 4Nos of iron hold fasts 50x6x230mm size etc.,complete.(ISI STD) 53 Supply & fixing of Tamilnadu Logo & Symbols as per design & Elevation. 54 Flooring with Joint free double charged vitrified tiles of approved quality, colour and design joint free of size 600 x 600 x 8mm thick of approved make, quality and colour in all floors over a base layer of cement mortar 1:3 (one cement three sand) 20mm thick and laid straight alignment and pointed neatly with colour cement at the rate of 0.40 kg/m2 laid without any air gap in the tiles neatly and fixing in position as per standard specifications and as directed by the departmental officers. Rate including all materials, labour charges, wastages, necessary lead and lifts, working at all levels, transportaion charges, loading, unloading,the same before handing over as complete with all respects complying with relevant standard specification and as directed by theClient / Engineer-in-charge. 55 Supplying and fixing UPVC windows of casement type Open from the profile the size of outer frame 60mm x58mm and shutter profileare reinforcement withGI/1mm125GSM and 100% Corrosion free,the profiles are multi Chambered sections with wall thick of 2mm. TheEPDM rubber covered with over all the edges of frame and shutter the shutter .will be provided with Espag multi power point locks and also it operates with Handle. The Corners and joint should bewelded and cleaned. Radiations free pin headed plain or brown colour glass 4mm thk should be provided to the shutter and it should not allow leakege of water even at most ranging storms and should have key lockable action, security protective hinges , strong locking system and as per size for arresting noise and energyloss. The connecting mechanism between sash and windowshould be fixed to the wall with 100% packing with screws and silicon Packing all roundthe frames. The window should be got approved from the Executive Engineer before use on work. 56 Providing of 35mm thick factory made pre-laminated ABS(Acrolynitrile Butadiene Styrene) Door Shutter moulded indifferent designs, consisting of all round frame made out of water proof solid foam PVC bar of size 20 x32mm, reinforcedby 32 x 32mm - 2 Nos., for vertical made out of LVL(Laminated Veneer Lumber), core material of 32mm thickhigh density craft paper honey comb board, sandwiched onboth sides with pre-laminated ABS sheet thickness of 1.5mm.PVC edge banding of size 0.45mm on the vertical sides.Hardware made out of steel coated butterfly hinges - 3 Nos.,for each shutter and ISI make SS round lock complete forfinished item of work, complete complying with the standardspecification. The door shutter and frame should be gotapproved from the Executive Engineer before use on work. 57 FRP Door Sutter with FRP Door Frames along with vision panel (as per drawing) made out of FRP Sheets of 3mm thick of over all size 65mm x 50mm with rebate suitably reinforced using MS Angle / Flats, cost of holdfasts and Solid Core FRP Shutter Panel of 5mm thick and hollow core frames of 3m wall thickness for styles and rails etc., of sizes specified by Engineers. 58 Supplying and fixing UPVC Louvered Ventilators of from the profile the size of outer frame 60mm x58mm and shutter profile size of 60mm x 78mm both profile are reinforcement withGI/1mm125GSM and 100% Corrosion free,the profiles are multi Chambered sections with wall thick of 2mm.The EPDM rubber covered with over all the edges of frame and shutter . The Corners and joint should bewelded and cleaned. Radiations free pin headed plain or brown colour glass 4mm thk should be providedin the Louvers.The window should be fixed tothe wall with 100% packing with screws and silicon packing all round the frames.The Ventilator should be got approved from the Executive Engineer before useon work. 59 FALSE CEILING WITH GYPSUM PLAIN TILES (600x600)Providing and fixing true horizontal level false ceiling using SAINT - GOBAIN GYPROC or Equivalent make with 24 mm Grid system using hot dipped galvanised Steel Section, exposed surface chemically cleaned caping prefinished in backed polyestar paint wall angle of size 24mmX24mm used in the periphery of the ceiling fixed to the wall partition R.C. Column bandwalls with the help of screws at 600mmc/c. Main runner of size 32X24mm suspended at 1200mm c/c max by using securely fixed to the structural soffit of R.C.C. slab by using 6mm Nylon Rawl plug at every 1200mm(Max) and 1200mm long Cross Tee of size 24X24mm to interlocked between Mainrunner at 600mm c/c (max) to form a grid of 1200mmX600mm. 600mm long Cross Tee of size 24X24mm is inserted to form a grid of 600mmX600mm and finally tiles laying with 12mm Gypsum plain Tiles as per stansdards 60 Providing & fixing of Brick Cladding in elevation as per drawing. The rate is inclusive of all necessary material , labour, transportation etc complete as per standards. 61 Supplying and Fixing of aluminium Dye Cast Letters of approved size and colour treatment processis achieved with MRF colour coat and then the processed coloured layer is set into the kiln for the heat treatment process for the following sizes aluminium Dye Cast Letters 6 Size. Tamil Stainless Steel Letters 25CM 62 Supplying and fixing M.S.Grill gate of required size in two shutters with necessary iron members, gun metal cups and wheels 75mm dia. with fittings locking arrangements,etc., complete,including painting a priming coat of approved primer,etc., complete (The design of gate furnished is subject to alteration during execution.) 63 Supplying and Painting the wall with Texture Finish Paint including thorough scraping, clean removal of dirt, Primer. The rate includes cost of materials, brushes, sand paper, rollers, plaster of parries, putty wherever required and neat finishing etc., complete complying with standard specification and as directed by the Departmental Officer (the colour and quality should be got approved by the Executive Engineer before use) 64 GYPBOARD DOUBLE SKIN PARTITIONProviding and fixing of Gypsum Dry wall Double skin partition of 75 mm thick using SAINT - GOBAIN GYPROC or Equivalent make and the partition shall be of one layers of tapered edge 12.5mm thk Gyp board screw fixed with dry wall screw of 25mm at 300mm c/c to either side of 48mm studs. GI steel sections to be placed at 610 mm c/c in 50mm floor and ceiling channel 0.55mm thick having equal flanges of 32mm made of GI steel with joints staggered to avoid leakage through joints. Finally square and tapered edges of the boards are to be finished so as to have a flush look which includes filling and finishing with jointing compound, joint paper and 2 coats of Drywall top Coat suitable for Gypsum upto primer level.As per India Gypsum Specs.Note: Angle Bead to be used at external angles to get straight line finish & protection from normal impacts. 65 Providing and laying water proofing treatment to vertical and surfaces for sunken portion of depressed portions of W.C., and the like consisting of :i) 1st course of applying cement slurry @ 4.4 Kg/sqm mixed with water proofing compound conforming to IS 2645 in recommended proportions including rounding off junction of vertical and horizontal surface. ii) 2nd course of 20mm cement plaster 1:2 (1 Cement : 2 Coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface. iii) 3rd course of applying blown or residual bitumen applied hot at 1.7Kg per sqm of area. iv) 4th course of 400 micron thick PVC Sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 Kg/sqm) 66 PLUMBING WORKS 67 Supply,erection and testing & commisioning of 3HP Submersible pumpset in the capacity of 6000 LPH @ 300Ft, max. total head of 350 Ft pumps fitted with bronze impellers and having delivery size of 40mm - 430V along with 3mts cable and manufactures standard control panel which is mandatory and as directed by the officer incharge.( Sump to OHT transfer pump) 68 Labour charges for the erection of submersible pumpset in borewell/openwell including fixingand jointing submersible cable with proper clamps upto the starter to required depth and also fixing of riser pipes to the required depth valves erection clamps, pressure gauges upto the exterior wall of pump room and erection of panel board consisting of TPICN switches starter, Voltmeter, Ammeter, three pilot (indicating) lamps capacitor single phasing preventor, water level guard and laying and jointing the cables and twin earthing as per IE rules etc., complete and testing the pumpset and trail run for 10 days. 69 Drilling of 6 dia vertical borewell so as to have a finished size of 6 dia borewell in boulder area to any required depth as decided by theincluding Transportation from one place to anothr place with in Tamilnadu State by direct or reverse rotary mud circulation method using Contractors rig tools, fuel, labourers, bentonite mud and water required for drilling at the site shown by the TWAD Officers including construction of mud pit etc. using only calyx rigs. 70 300mm 71 Charges for developing the borewell with air compressor of 300 CFM capacity (Minimum 8 Hours) including transportation labour and fuel charges for compressor as directed by TWAD Board Officers and conducting yield test by V notch method. 72 Supply and laying following dia PVC casing pipe with excise duty as per IS 12818 / 1992 73 200mm dia CS ( plain pipe) 74 150mm dia CS ( plain pipe) 75 Labour charges for inserting PVC casing pipes assembly (with slots or without slots) in the drilled hole including jointing the pipes with PVC couplers with cement paste etc., complete, supply and packing the annular space with pebbles of size and quality as approved by the Executive Engineer of Departmental officers. 76 200mm dia CS ( plain pipe) 77 150mm dia CS ( plain pipe) 78 Supply and fixing in position whiteEuropean Water Closet of approved make with low level concealed flushing tank 10 litre capacity of best quality and approved make with 100mm P or S trap with double flapped rigid PVC seat cover with CP brass hinges etc. complete complying with standard specification and as directedby the Departmental officers (The EWC should be got approved by the Executive Engineer before use on works.URINAL WITH FIXING ACCESSORIES SET, SIZE - URS-WHT- 13253N 79 Supplying and fixing Wash Hand Basin of size 550 x 400mm with all accessories such as cast Iron Brackets, 32 mm Dia C.P. Waste coupling, Rubber plug and Chain, 32 mm dia B Class G.I. Waste pipe, 15 mm Dia G.M Wheel valve; 15 mm Dia Nylon connection, 15 mm Dia Brass, wast couplingNipples, 15 mm C.P. Pillar tap etc.,including fixing the wash hand basin in the wall in position with a pair of C.I. brackets with teak wood plugs and screws and giving necessary water supply connection and as directed by the Department officers.(TheWash basin should be got approved by the Executive Engineer before use on works. 80 Supplying and fixing of CP Two Way Bib Cock with Health Faucet ,wall hook & one metre longflexibletubeincludingcuttingandmakinggoodthe wallswherever requiredetc complete.complyingwithstandardspecificationandas directedbytheDepartmentofficers.Thequalityandmakeofhealth faucet should be got approvedby Concern department Engineer before use on work. 81 Supplying and fixing the best quality approved make of SS heavy duty long body Tap including cutting and making good walls wherever required etc.complete,complying with standerd specification and as directed by the department officers. The quality and make of angular stop cock should be got approved by concern department engineer before use on work. 82 Supplying and fixing in position Mirror of size 600x450mm of approved quality and brand with necessary plastic back PVC frame with bottom stand using brass screws rawl plugs for fixing etc complete complying with standard specification and as directed by the Departmental officers.The colour of frame and quality of mirror should be got approved by the Executive Engineer before use on work 83 Supplying,installing,testing and commissioning of approved make CONCEALED STOP COCK for toilet including neccesary accessories etc,complete,works include making require size curout in wall,and fixing the control box property,redoing the same etc,complete the quality and make of concealed stop cock should be got approved by concern department Engineer before use on work. 84 Supplying and fixing CP angle cock with wall flange including cutting and making good the walls wherever required etc., complete complyingwithstandardspecificationandas directedbythe Engineer Incharge before use on work. 85 Supplying and fixing in position best quality PVC soil / waste pipes of various dia having 6 kg ,10 kg /sq.cm. pressure BIS mark and providing leak proof joints using PVC adhesives including fixing to the wall with special PVC / MS clamp, teak wood plugs, brass screws, etc., and making connection to all sanitary fittings, dismantling masonry / RCC works wherever found necessary and making the good dismantled portion to the original condition, including testing for any leakages, etc., complete complying with standard specifications.(The PVC pipes should be got approved by the Executive Engineer before use on works). 86 160mm Dia 6kg 87 110mm Dia 6kg 88 75mm Dia 6kg 89 50mm dia 6kg 90 Supplying andfixingPVC cowl of following size to vertical Soil/Waste pipes above terrace level. The rate including cost of all materials, labour charges and transportation etc. completed as directed by Engineer-in-Charge. 91 110mm dia 92 Supplying & fixing in position PVC Nahini / Floor trap of size 100x75mm including stainless steel gratings of approved brand & quality, fixed over a bed of brick jelly limeconcrete 1:2:5 ( One part of lime, two parts of sand & five parts of 40 mm size brick jelly ) & finished with cement mortar 1:3 ( One cement & three sand ) includingdismantling masonry works wherever found necessary & making good the damaged portions to the original condition & giving connections to the cast iron pipes etc., complete, complying with standard specification. (The PVC Nahini / Floor trap should be got approved by the Executive Engineer before use on works ). 93 Constructing solid block masonry manhole various size of deep in cement mortar 1:3( 1 Cement: 4 coarse sand ) R.C.C. Raft & top slab with cement concrete 1:2:4, plain cement concrete 1:4:8 mixfor base course (1 cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size )above that 150 mm thick RCC M25 raft slab inculding reinforcement 10mm dia 150mm c/c bothways. Plastering inside walls with 12 mm thick cement mortar 1:3 (1 cement : 3 coarse sand ) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size ), finished with a floatingcoat of neat cement ,supplying and fixing SFRC manhole cover with farame , PVC foot rest as per detailed drawing etc the quoted rate shall also necessary excavation and back filling etc complete.complete as per standard design : (the chamber and cover should be got approved by the Executive Engineer before use on works) 94 Manhole 600 x 600 mm internal size ( Depth up to 1000mm) 95 Supplying, laying and jointing CPVC pipes SDR 11(having working pressure 10 kg. / sq.cm) of approved quality and best variety conforming to BIS of the following dia including cutting, threading and fixing CPVC specials using CPVC adhesivesand fixing into wall with teak wood plugs, CPVC clamps and screws making holes on the wall (or) drilling holes in the roof and making good the dismantled portion to original condition with necessary brick work / cement concrete and plastering neatly wherever necessary with necessary scaffolding charges upto 4 metre height above ground level, etc., complete complying with standard specifications.The CPVC pipes shall be got approved by Executive Engineer before use on works.Internal & Vertical 96 a) 20 mm dia 97 b) 25 mm dia 98 c) 32 mm dia 99 Supplying and fixing manhole cover with frame as per approved make ,cover weight and being size mentioned below and specified size in the drawing etc., including painting with two coats of anticorrosive paint over a coat of primer etc., fixing locking arrangements, fixing Man-hole over, grouting the anchors with CC 1:2:4 (one cement,two fine aggregate and four coarse aggregate), as complete in all respects complying with relevant standard specifications and as directed by theClient / Engineer-in-charge.Size:600x600mm 100 Supply & fixing of Bottle trap as per standards. BOTTLE TRAP (WITH INTERNAL PARTITION) 32 - ALD-CHR- 769L300X190 101 LANDSCAPING WORKS 102 Planting of Ixora hybrid foliage shrub variety of height 30-45 cm in polythene bag of size 6x8 inchincluding loading and unloading charges, transportation, stacking of saplings at site, earth work excavation of required size, planting of sapling, refilling of excavated earth etc as directed by the site in-charge. 103 Planting of Ficus black ornamentalfoliage shrub varietyof height 30-45 cm in polythene bag of size 6x8 inch including loading and unloading charges, transportation,stacking of saplings at site, earth work excavation ofrequired size, planting of sapling, refilling of excavated earth etc as directed by the site in-charge. 104 Planting of Jasmine Plant foliage shrub varietyof height 30-45 cm in polythene bag of size 6x8 inch including loading and unloading charges, transportation,stacking of saplings at site, earth work excavation ofrequired size, planting of sapling, refilling of excavated earth etc as directed by the site in-charge. 105 Planting of Travellers palm ornamental foliage Specimen plantvarietyof height 105-120 cm in polythene bag of size 16x16 inch including loading and unloading charges, transportation,stacking of saplings at site, earth work excavation ofrequired size, planting of sapling, refilling of excavated earth etc as directed by the site in-charge. 106 FURNITURE WORKS 107 Linear type Workstation (1000mm(W) X 600mm(D) X 750+300mm(H)) as per below specificationTable Top: - Made of 25mm Thick E1 Grade Pre-Laminated Particle Board with 2mm PVC Edge Banding.Main Screen : -8mm Sandwitch Glass finishes of Sizes 1050x300mm htUnderstructure: - MS Square Leg cross-section of size 50 x 50mm is Made of Mild Steel 1.6mm thick CRCA Powder coated.MS Powder Coated horizontal Beams supported below the table top of Size 50*25mm. Rectangular Tube made of 1.6mm thick CRCA Powder coated.Raceways : -Vertical Raceways - 120 MM HT MS Powder Raceways Considered below the Table top With Intermediated legs considered for Wire Provision.Without Middle Cover.Wire Manager: - Wire Manager Hole considered. 108 Storage (Open Shelf) 1200mm 300mm 2100mmIs made 25mm top & all other panel 17 mm thick in prelam particle board finished in Laminate of approved shape, equal shutter 2mm thick edge banding finished. This also includes providing and fixing of hardware like locks, handles, spring loaded hinges etc 109 Supply of Chairs 110 ASPIRE MB (BLACK)* Black Backrest frame, Polished aluminum connected* Mesh back, Seat and headrest fabric* Height adjustable lumbar support with PU surface* Tiltable backrest (can be tiltable when locked inupright position)* 4D adjustable armrest with PU pads* Mould foam with plastic seat upholstery* Mechanism, with seat slide.* Chrome gaslift* Polished aluminum base with plastic cover,* 60mm nylon castors 111 * Versa Medium Back Mesh Chair* AN -70 Mesh* Single Lock Synchro Mechanism* Adjustable Lumbar Support* One Way Adjustable Armrests ( Height)* Nylon Base* Fabric Upholstered Cushion Seat 112 Meeting Room TableTable Top: -Made of 25mm Thick E1 Grade Pre-Laminated Particle Board with PVC Edge Banding,Understructure: - MS Leg 50mm 50mm is Made of Mild Steel 1.6mm thick CRCA Powder coated.MS Powder Coated horizontal Beams supported below the table top of Size 50*25mm.Raceways : Horizontal RacewaysMS Powder Raceways Considered below the Table top With Intermediated legs considered for Wire Provision.Wire Manager:- Flip Cover Considered. 113 Meeting Room Table (2400mm 800mm 750mm) 114 Cabin Main Table with Side Storage (Main Table 1500mm 750mm 750mm / Side Storage 1200mm 450mm 750mm)Side Storage 1200mm 450mm 750mmTable Top: Main and Side Table Made of 25mm Thick E1 Grade Single Top PLPB with 2mm PVC Edge Banding,Understructure: MS Square 50mm Steel 1.6mm thick CRCA Powder coated.MS Powder Coated horizontal Beams supported below the table top of Size 50mm x 25mm.Flip Cover : Flip Cover 400*143mm Made of AluminiumWire Manager: Wire Box with Socket Plate and Vertebra considered for wiringModesty : Front & Side PLPB Modesty Panel . 115 Librarian TableMain Table 1100mm 440mm 750mm 116 3 Seater Sofa with Table 117 INTERACTS-902 (Leatherette)3 SeaterSize : 1810 (W) x 720 (D) X 740 (H)Made off : the sofa is made of fine quality leatherrite (3s = 8.0 mtr,2s = 6.8 mtr, 1s= 5.3 mtr), the structure is made from silver wood& pine wood, 32 & 40 density foam is used which is covered withroll poly filling for giving comfort and extra softness to sofa. Extra(kangaro company)Legs : are made of stainless steel.Color : Black 118 ELECTRICAL 119 TNEB METER BOX 120 Supply andfixng of TNEB meter board suitable for 3phase100A service connection made up of suitable angle iron frame work of size 2feet x 1-1/2 feet using angle iron of size1-1/2x1-1/2x1/4rigidly fixed on wall covered with hylem sheet of size 2 feet x 1-1/2 feet of 12mm thickness with necessary bolts and nuts supports and supply and fixing of 3Nos.100A fuse units (500V), 1No .neutral link,copper earth flat of size1x1/4with inter connection of EB meter to fuse units by 16 Sq.mm PVC insulated copper wire with earth connection complete. 121 M.S. Enclosure (IP65): Supply, Erection , Testing and commissioning of the followingtype M.S. powder coated enclosure for housing the Meteringing service, whch should be made outof16SWG enclosure with provision for cable entry, with Outdoorapplication IP65 as specified Protection, fixed on the wall/Floor withall accessories, pedestal frame with concrete grouting or suitable to fix at concrete plinth etc. 122 MAIN Panels 123 MAIN Panels:Supply, Installation, testing and commissioning of 3Phase, 415Volts, Main LT Panel board of Indoor, Cubicle floor mounting type made out of14 SWG CRCA sheet steel with powder coated finishing, MS base frame, double internal earthing arrangements, 100Amps, rating TPN Copper busbars and Earth bar with interconnection busbar, etc., comprising of the followings:EB Incomer :1 No. 100Amps, 25kA, 4Pole, Thermal magnetic MCCB with Ext.RHOMDG Incomer: 1 No. 100Amps, 25kA, 4Pole, Thermal magnetic MCCB with Ext.RHOMCommon C/O Incomer: 1 No. 100Amps, 4Pole Automatic Changeover Switch with EB ON and DG ON LED Indication lampsMetering : 2 Set of RYB LED Indication lamps2 Nos. of Multifunction Meter with RS 4852 Set of Current Tranformers (200/5A, Cl-1), 1 No. 200/5A CT for APFCR2 Set of Control MCB and Electrical Interlocking between EB & DG Incomers Outgoings: 3 Nos. 63A, 25kA, TP+N, TM MCCB with Ext. RHOM (APFCR &AC)4Nos. 32A, 25kA, TP+N, TM MCCB with Ext. RHOM (Lighting & Spare),6Nos 32A DB MCB inclding all labour Charges And Transports Charges. 124 APFC PANEL: Supply, installation, testing and commissioning of 25 KVAR Automatic power factor correction panel ( APFC ) with 8 steps of capacitor switching cubicle type, free standing, Powder coated, 14 SWG CRCA sheet steel,enclosed separate compartment for each capacitor, front operated, indoor type dust and vermin proof, hinged, lockable doors, electrolytic grade aluminium bus bars, with SMC /DMC insulator supports, Digital volt meter, Ammeter with selector switch, 8 stage Digital Automatic power factor correction,( APFC ), Auto / Manual selector switch, cluster LED typeindicators, in the incomer,complete with electrolytic grade aluminium bus bars, MPP type Power capacitors, with 5 KVAR x 3 no. 3 KVAR x 2 nos. 2 KVAR x 1 nos. 1 KVAR x 2no. Contactors, MCCB’s, start, stop, push buttons, internal wiring, colour coding, ferrules, cable gland plates, Aluminium earth bus for the entire length of the panel with bonding to earth and painting,Panel mounting MS Channels, fasteners, etc., including all associated control wiring and interlocking circuitry, Main panel sensing CT interconnecting wiring etc., all inclusive. 125 Supply, Installation, testing and commissioning of 1 x 58.5KVA, Silent type Diesel Generator Set with AMF Panel complete with suitable size Acoustic enclosure CPCB IV and BIS. Diesel Engine suitable for Generator application, developing 1500RPM with an overloading capacity of 10% for one hour in any 12 continuous hours operation generally confirms to BS:5514, directly coupled to 58.5KVA at 0.8 Power factor, 415V, 3Phase , 4wires, 50cycles per second self excited, self regulated, with brushless excitation, Alternator generally confirms to BS:5000/IS:4722. DG set shall be complete with radiator, residential type silencer, electronic governor, cable termination box, MS mounting frame, fuel piping, diesel day tank, 24VDC Battery, Battery mounting frame, oil level indicator with gauge board, andall other accessories as per standard specifications.Diesel Generator set shall be mounted on cushy foot or similar type of vibration Isolators. The cost of Exhaust pipe shall be included in this item with Sutable concrete Base at M30 Grade. The DG Set shall be suitable for auto-mains failure startand auto / manualoperations.The DG Should be supplied with Auto-Start-Stop Control panel with suitable rating switchgear 126 DISTRIBUTION BOARDS 127 Supply and fixing of 12 way single pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1no. 32A DP MCBswitch as incoming and 10 nos. 6A to 32A SP MCB as outgoing in flush with wallwith earth connection only.Higher End 128 Supply and fixing of 4 way Horizontal Triple pole and neutral MCB sheet steel enclosure distribution boardwith double door (metal) with 1 no. 32A 4P MCB switch as incoming and 12 nos. 6A to 32A SP MCB asoutgoing in flush with wall with earth connection only. Higher End 129 Supply and fixing of 7 segment 4 way TPN MCB sheet steel distribution board (Higher end) with metal / acrylic door cover flush type /surface type fitted with busbars and neutral links with single / three phase MCB outgoings and seperate 4 way provision for accomodating one no. 4 pole incoming MCB / Isolator and another seperate 4 way provision for accomodating one no. 4 pole ELCB / RCD (totally 8 ways in one segment) (3x 4 ways in each segment) and seperate provision for MCB / Isolators ( totally 12 nos.) for sub incomers in 3 segments with lable holder and provison for taking up cable for size not less than 35 sq.mm.with the following in flush with wall with earth connection only. i. 63A 4P MCB - 1 no.ii. 63A 4P 30MA RCCB/ELCB - 1 no.iii. 63A DP MCB Isolator -3 nos.iv. 6A to 32A SP MCB - 12 nos., 130 Supply and Laying of 3 1/2x 70 sq.mm. PVC armoured LTUG cablein suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good. 131 Supply and fixing of brass cable gland for 3-1/2 x 70 sq.mm. PVC armoured LTUG cable with earth connection. 132 Supply and providing cable end termination of 3-1/2 x 70 sq.mm. PVC LTUG aluminium armoured cable with necessary aluminium cable sockets by crimping etc with electrical connection complete. 133 Run of Mains 134 Supply and Run of 4 of 10 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection of 10 sq.mm copper wire and making good of the concealed position. 135 Supply and Run of 2 of 4 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with continuous earth wire connection by 4 sq.mm. PVC insulated SC unsheathed FRLS copper wire and making good of the concealed portion. 136 Supply and Run of 2 of 10 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection of 10 sq.mm copper wire and making good of the concealed position. 137 Supply and Run of 2 of 2.5 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with continuous earth wire connection of 2.5 sq.mm copper wire and making good of the concealed portion. 138 Point Wiring 139 Wiring with 2 x1.5 sq.mm. PVC insulated single core unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with PVC accessories with Module GI switch box in flush with wall with 6A one way module switch with module front plate with continuous earth wire connection of 1.5 sq.mm copper wire and making good of the concealed portion with suitable colour for Concealed PVC Light point / fan point (for electronic regulator) Higher End Primary Point. 140 Wiring with 2 x1.5 sq.mm. PVC insulated single core unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with PVC accessories with continuous earth wire connection of 1.5 sq.mm copper wire and making good of the concealed portion with suitable colour for Concealed PVC Light point / fan point (for electronic regulator)Higher EndSecondary Point. 141 Switch & Sockets 142 Supply and fixing of 1 no.6A two module 5 pin socket , 1 no.6A one module switch with module cover plate (plastic) onsuitable module concealedBox (GI ) in flush with wall with connections. Higher End 143 Supply and fixing of 2nos.6A two module 5 pin socket , 2 nos.6A one module switch with module cover plate (plastic) onsuitable module concealedBox (GI ) in flush with wall with connections. Higher End 144 Supply and fixing of 1 no.6/16A two modulesocket , 1 no.16A one module switch with module cover plate (plastic) on Suitable module concealedBox (GI ) in flush with wall with connections. Higher End 145 Supply and fixing of 20A Flush type Wall Socket 32A DP MCB complete set for AC Plug in flush with wall with earth connection (For AC Plug) 146 Air Condition 147 Supply & Instalation of Air-Conditioner with Copper Coil 2.0 TR Split Type AC Unit - 5 Star Rated, 5 KVA capacity Automatic Voltage Stabilizer with time delay relay, 5/8” and 3/8” copper pipe (Extra beyond 3 metres supplied with AC unit), Inculding MS stand for fixing outdoor unit. 148 Supply and fixing of Copper Refrigerant Piping of 3/8 dia and 5/8with Pipeline nitrle rubber insulation with 50mm PVC water drain pipe line with Non Adhesive Cotton Roll insulation and 3 core Power cable from indoor to Outdoor unit. 149 Supply and fixing of 450mm (18) Wall mounting 5 star rated complete (Higher end) with necessary accessories and hardwares as required. 150 Supply and fixing of 300mm (12) sweep(Heavy Duty) AC exhaust fan complete with necessary wall opening and making good of the wall . 151 Supply and fixing of louvers shutters arrangements for 300mm (12) sweep AC exhaust fan 152 Supply and fixing of 24W LED 2x2 square type Recessedfitting with LED (Higher end) on false Ceiling with suitable hanging support from ceilingwith PVC unsheathed copper leads from terminals to the fitting 153 Supply and fixing of 18W LEDRound type Recessedfitting with LED (Higher end) on false Ceiling from ceilingwith PVC unsheathed copper leads from terminals to the fitting. 154 Supply, installation, testing and commissioning of36 W, 900mm diaCircular LED pendantlight fitting, made out of CRCA powder coated body, aluminium reflectors,poly methyl meth acrylate (PMMA) diffuser, glare free light, suitable for recessed mounting including electronic drivers, day light colour LED lamps, inter connecting wiring including accessories all inclusive. KL 3232 155 Supply and fixing of28Watts GATE FIXTURE FITTINGwith cool day light suitable for wall / roof sheet mounting, made outCRCA powder coated body,IP65 aluminium reflectors,poly methyl meth acrylate (PMMA) diffuser, glare free light, including electronic drivers, day light colour LED lamps, inter connecting wiring with suitable fixing clams, hooks as required including accessories all inclusive.(Klite/Millenium/Bajaj Equivalent) 156 Supply and fixing of 8W Light fitting (IP67) Inground fixture with PVC unsheathed copper leads from terminals to the fitting and to complete necessary accessories and etc to complete the work. (Klite/Millenium/Bajaj Equivalent) 157 Supply and fixing of MIRROR Light 20W LED Batten 158 Supply and erection of Canon Digital Photocopier (Xerox) Machine IR-3300 / 3235Type of Product : Laser Multi functionalCore Functions: Print, Copy, Scan & SendFirst Copy Time:3.9 SecMultiple Copies :1 to 999 SheetsPrint Speed :45ppmThe laser beams engrave the image or text that you have sent to print on the surface of the drum. When using a copier this process is done using light, the light scans the page required for printing and converts it into an image 159 Supply and erection ofAll-in-one Desktop of HP 27-cb1456in Core i5 (8GB DDR4 /Windows 11 Home/27 Inch Screen/27-cb1456in) with 600VA UPS, Keyboard, Mouse,27 inches, 11th Gen Intel Core i5-1235U6 x 1.8 GHz (Turbo Speed upto 4.2 GHz) Cores Hexa Core, 12 Threads, 18 MB Cache, UHD Graphics 730 Graphics, 8 GB DDR4 RAM Smallest and 512 GB SSD.Ethernet (LAN), HDMI, Multi Card Reader,WiFi, Bluetooth v5.03 x USB 3.0, 1 x USB Type-C and Inbuilt Microphone 160 PRINTER: Supply, installation, testing and commissioning of HP Smart Tank 790 WiFi All-in-One Printer Duplexer with ADF and Magic Touch Panel Inkjet Colour printer, print speed 11-20 sheets with multiple features like print, scan, copy, fax, multi-port connectivity (Hi-speed USB 2.0, Wifi, Bluetooth LE , 1 USB Host, LAN) , 2.4/5G dual band Wi-Fi, Wi-Fi Direct, mobile printing capability, etc 161 Supply, installation, testing and commissioning of Long Range Wifi Device of following Specification: Networking Interface: (1) GbE RJ45 PortPower Method: PoE+, Pasive poE(48V) Max TX power: 2.4 GHzAntenna gain: 2.4 GHzMounting: Wall or Ceiling MountingWifi Satndards : 802.11a/b/gWireless security: WPA-PSK, WPA- Enterprises(WPA/WPA2/WPA3)VLAN: 802.1Q Concurrent Clients: 300+ 162 CCTV 163 Supply, Installation, Testing and commissioning of 16 channel 2 SATA NVR, with 6TB Hard Disk Drive 2 nos, New logical and visualized GUI design Dual-OS design to ensure high reliability of system running, ANR technology to enhance the storage reliability when the network is disconnected,Configurable normal or hot spare working mode to constitute an N+1 hot spare system Video Input and Transmission, Connectable to the third-party network cameras Compression and Recording, H.265+ compression effectively reduces the storage space by upto 75%, Full channel recording at up to 12MP resolution HD Video Output  HDMI1 / VGA1 outputs provided  HDMI1 Video output at up to 4K ( 3840 × 2160 ) resolution Storage and Playback, Upto 16 SATA interfaces and 1 eSATA interface for HDD connection, Support upto 10TB capacity for each HDD, Smart search for efficient playback. and smart playback to improve the playback efficiency, Supports VCA search for fire/ship/temperature/temperature difference detection triggered video files, POS information overlay on live view and playback, POS triggered recording and alarm Network & Ethernet Access  Hik-Connect for easy network management, 2 Gigabit Ethernet network interfaces. (Make : Hikvision / Dahua / Sony. 164 Supply of 4MP, Internet Protocol fixed BULLET CAMERA/DOME CAMERA (INDOOR & OUTDOOR)with following specification:●1/2.5 Progressive Scan CMOS, ● 3840 × 2160 @15 fps,2.8/4 mm fixed lens,01 lux @ (F1.2, AGC ON), 0.028 lux @(F2.0, AGC ON), 0 lux with IR, H.265+, H.265, H.264+, H.264, 2 Behaviour analyses ( Line crossing detection, intrusion detection)● Face Detection ● 120dB WDR, ● BLC/3D DNR/ROI, IP67 complied●On-board Storage -Built-in micro SD/SDHC/SDXC card slot, up to 128 GB,● Shutter Speed 1/3 s to 1/100,000 s, ● 3-Axis Adjustment Pan: 0° to 360°, tilt: 0° to 100°, ● rotate: 0° to 360°, 2.8 mm, ● horizontal FOV: 102°, vertical FOV: 53°, diagonal FOV: 124°, ●Lens Mount M12 ● IR Range I5: up to 50 m, ● Image Settings Rotate mode, saturation, brightness, contrast, sharpness adjustable by client software or web browser, ● Power Consumption and Current-12 VDC, 0.7 A, max. 7.5W PoE: (802.3af, 36V to 57V), 0.3 A to 0.2 A, max. 9W● Camera out fitted with metal housing so as to prevent the lens from damages during physical abuse. with Camera Stand and camera fixed connecting box. (Make: Dahua/Panasonic) 165 Supply, Installation, Testing and Commissioning of 32 smart LED TV with following specifications a) Full HD 1920 x1080 (4K monitor) b) IPS panel c) Slim back light LED module d) 900 PMI e) Triple XD engine f) Dynamic scanning g) ANRh) True colour generatori) 8modes of picture j) picture wizardIII k) Real cinema 24P l) HDMI -3nos m) USB -3nos n) Built in LAN (Make: Sony/ LG /Samsung). 166 Supply and Clamping of CAT 6 unarmoured cable in suitable PVCPipe 1 thick on wall / ceiling with connected PVC accessories with clamps, saddles etc., complete. (Between ethernet switch to camera and radio modem)i. Application : Primary (Campus), Secondary (Riser), Tertiary(Horizontal)IEEE 802.3 : 10Base-T; 100Base-T; 1000Base-TIEEE 802.5 16 MB; ISDN; TPDDI; ATMii. Standards: ISO/IEC 11801 2nd ed.; IEC 61156-5 2nd EN 50173-1; EN 50288-6-1,EIA/TIA 568C.2, RoHS Compliant. ii)Fire Rating: PVC : IEC 60332-1.iii. Conductor - Bare Copper Wireiv. Insulation - Polyethylene v. Twisting - 2 Cores to the pair vi. Cable lay up - 4 Core to the pair It has diameter of (23 AWG) 0.550 ± 0.015.Insulation : Polyethylene.GI wire of size is 0.90 ± 0.030mm. 167 Supply and Fixing of Rack with Accessories -Higher end9U Rack with fan extra for the above rack. (Amp/NVR/POE) 168 Supply and Fixing of Rack with Accessories -Higher end4U Rack with fan extra for the above rack. (speaker/data/cctv) 169 Supply and fixing of POE 24 port switch10/ 100 / 1000 Base -T / 2 x 1000Base-FX / 20Gbps bandwidth / IEEE803.af/at compliant PoE+ / RJ45 supports auto MDI/MDI-X function / Auto negotiation speed, half/full-duplex / Store and forward / Max packet size: 10kbytes / Wide range power design (12~56VDC) / Operating temperature (-40 ̊C ~ +75 ̊C) / Reverse polarity protection / Resettable fuse to protect against overcurrent / IP-40 protection / EFT protection for power line. (Make: DLINK,NETGEAR/ TPLINK) 170 Supply and fixing of POE 8 port switch with two uplink port, 10/ 100 / 1000 Base -T / 2 x 1000Base-FX / 20Gbps bandwidth / IEEE803.af/at compliant PoE+ / RJ45 supports auto MDI/MDI-X function / Auto negotiation speed, half/full-duplex / Store and forward / Max packet size: 10kbytes / Wide range power design (12~56VDC) / Operating temperature (-40 ̊C ~ +75 ̊C) / Reverse polarity protection / Resettable fuse to protect against overcurrent / IP-40 protection / EFT protection for power line. (Make: DLINK,NETGEAR/ TPLINK) 171 Supply and fixing of outdoor4X6PVC box with 102mm x 77mm x 102mm with all fixing accessories. 172 Supply, Fixing and Termination of CAT 6 Cable RJ 45Jack Single Point ( Point to Point ) Crimping, Testing and arrangement charges. 173 Supply and Installation for 1KVA UPS with Battery, Single Phase UPS (Single Phase In & Single Phase Out) Capacity - System with Battery - 2 Hours back up and battery stand . 174 Supply, Erection of 6mLengthpole with base plate of size 300x300x12mm as per IS-875 with following specification. Pole Outter dia -76.10mm x 3.65mm Thick x 6 meter with foundation Charges. 175 VOICE & DATA 176 Supply, Fixing and Termination ofRJ 11 Single Point ( Point to Point) Crimping, Testing and arrangement charges. 177 Supply & Installation of CAT 6 PVC Module Box I/o socket & face plate single socket Erection and arrangement chargers (Higher end) 178 Supply and fixingofLAN Network Switches Un-Managed 10/100/1000 - 24 Port and 24 Port Patch Panel- Unloaded erection and arrangement chargers. 179 Supply, runing, testing and commissioning of2 Pair Unarmoured 0.5mm Telephone cable in suitable Pvc Rigid pipe concealed on wall and ceiling with continuous earth wire connection with painting of suitable colour. 180 PA SYSTEM 181 Supply, Installation,Testing & commisioning of 15W Wall Speaker 2 way high efficiency, high fidelity, long throw IP65 weather proof P.A Music Horn speaker. It combines the high efficiency of horn with wide frequency response.Music horn is weather protected and UV protected ABS plastic housing combines with the feature of easy poertap selection on a terminal strip with a two core cable.It has impedence of 250/500/1k/2k ohm with frequency response of 120-16000 hertz. (Make:AhujaAMH402T/Bosch or its equivalent) 182 Supply, Installation,Testing & commisioning of 120 watts P.A Mixer Amplifier with the output power of 120 watts maximum 160watt rms at 10% Thyristor harmonic distortion(THD), 850watt RMS at 5% THD, 800 wattsRMS at 2% THD and the power supply AC voltage ranging from 220-240 volt, 50/60 hertz. with the DC input of 48 volt and 1000watts has tone controls of Bass=+- 10 db at 100 hz weighing 42kg with the speaker output of2Q,4Q.70volt&100volt has power consumption of 1600VA AC &12A DC and 100db output regulation at 1khz no load to full load ratio. The signal to noise ratio is 60db with the imnput channels of 0.8mv/4.7kq,3*Aux 100mv/50kq.The frequency response of 50-15000hz+-3db.(Make:Ahuja SSA 10000/Bosch) 183 Supply, runing, testing and commissioning of2Core x 1.5sq sqmm PVC insulated un Armoured Speaker Cable in suitable 20mm dia Pvc Rigid pipe concealed on wall and ceiling with continuous earth wire connection with painting of suitable colour. 184 Earthing 185 Earthing as per the ISI specification with an earth electrode of 2.10 metre Class B GI pipe of dia not less than 40mm withcopperearthplateofsize125mmx50mmx6mmwithnecessaryfunnellingarrangementswithnecessary masonry work and with 38mm RCC cover slab for the brick masonry 186 Supply and erection of 17.2mm, 3mtr long, Copper Bonded earth rod with backfill compound, including civil worksof base PCC for chamber andheavy duty Chambercover,, heavy duty chamber cover, etc., as per IS 3043 standards 187 Supply and run of 25mm x 3mm tinned copper flat with necessary clamps / supports on wall / floor / ground for earth connection 188 Supply and Run of1 of No.8 SWG copper wire for earth connection 189 Supply and Run of1 of No.8 SWG copper wire in suitable PVC rigid pipeon wall / floor / ground for earth connection 190 Supply of 2mx1mRubberMatsuitablefor11KVinstallation confirming to IS(5 Nos) 191 Supply of First Aid Box complete with all First Aid Medicines 192 Supply and fixing of Shock Treatment chart with Glass frame 193 Supply and fixing of4 Nos. Fire Buckets made out of 40 x 40 x 6mm MS Angle 194 Supply and fixing of Fire Extinguishers Co2, 4.5Kg confirming to TAC norms 195 Supply and fixing of Metallic Danger Board as required by the Electrical Authorities 196 METAL SIGNAGE BOARDS: Supply and fixing of metal signages for the following:1. Mudhalvar Padaipagam text in Tamil of size 20 x 15with backlit LED placed over the base, fabricated using stainless steel sheet of minimum 16G thickness brush finish of required size and colour as required. 197 LOGO SIGNAGE BOARD 198 LOGO SIGNAGE BOARDS: Supply and fixing of acrylic signages for the following:1. Mudhalvar Padaipagam logo of size 2 x 22. CMDA logo of size 2 x 33. Directorate of Public Libraries logo of size 3 diawith backlit LED placed over the sun board base, SIDE EDGES(4): 5mm transparent white acrylic sheet with laser cut & 4inches manual raising all around with details. ACRYLIC SHEETS & ITS TECHNICAL PARAMETERS:Front: a. 5mm Imported (Mitsubishi/equivalent) acrylic cutting on laser cutting machine.b. Flexi bond make 25mm Sun board for the back of the logo.
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 2
38.
Communications and Information Technology  #10196917 Price Bid
Tender For Day To Day Maintenance To Bsnl Buildings In Jalandhar Ssa For Theyear 2024-25; 1 Providing and laying cement concrete in retaining walls, return walls,walls (any thickness) including attached pilasters, columns, piers,abutments, pillars, posts, struts, buttresses, string or lacing courses,parapets, coping, bed blocks, anchor blocks, plain window sills, fillets,sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing 2 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) 3 Brick work with common burnt clay F.P.S. (non modular) bricks of classdesignation 7.5 in superstructure above plinth level up to floor V level inall shapes and sizes in : 4 Cement mortar 1:6 (1 cement : 6 coarse sand) 5 Providing and fixing 6mm thick commercial plywood of ISI marked and BWR grade of approved make in counters,cupboards etc. i/c cost of fevicol,nails complete in all respect as per direction of Engineer-in-Charge. 6 Providing and fixing 12 mm thick commercial plywood of ISI marked and BWR grade of approved make in counters,cupboards etc. i/c cost of fevicol,nails complete in all respect as per direction of Engineer-in-Charge. 7 Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws excluding, panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. 8 Red/Yellow Mirandi wood 9 35 mm thick shutters 10 Providing and fixing glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws. 11 Red/Yellow Mirandi wood 12 30 mm thick 13 Providing and fixing wire gauge shutters using galvanized M.S. wire gauge of average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm, for doors, windows and clerestory windows with hinges and necessary screws: 14 Red/Yellow Mirandi wood 15 30 mm thick 16 Providing and fixing 6mm thick Bekelite Sheet of ISI marked of approved make in counters,cupboards etc. i/c cost of rubber,fevicol,nails complete in all respect as per direction of Engineer-in-Charge. 17 Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 gradedstone aggregate) finished with a floating coat of neat cement, includingcement slurry, but excluding the cost of nosing of steps etc. complete 18 40 mm thick with 20 mm nominal size stone aggregate 19 Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), includingfinishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : 20 In 75x75 mm deep chase 21 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with sealring conforming to IS : 5382, leaving 10 mm gap for thermal expansion,(i) Single socketed pipes. 22 110 mm diameter 23 White washing with lime to give an even shade : 24 Old work (one or more coats) 25 Distempering with 1st quality acrylic distemper (ready made) havingVOC content less than 50 gm per ltr. of approved manufacturer and of required shade and colour complete. as per manufacturer’s specification. 26 One or more coats on old work 27 Finishing walls with water proofing cement paint of required shade 28 Old work (one or more coats @ 2.20 kg/10 sqm) complete 29 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : 30 One or more coats on old work. 31 Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq. meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground within 50 metres lead : 32 With cement mortar 1:4 (1 cement : 4 fine sand). 33 Renewing glass panes, with wooden fillets wherever necessary: 34 Float glass panes of nominal thickness 4 mm (weight not less than 10kg/sqm) 35 Renewing glass panes, with putty and nails wherever necessary including racking out the old putty: 36 Float glass panes of nominal thickness 4 mm (weight not less than 10kg/sqm) 37 Re-grading terracing of mud phaska covered with tiles or brick, in cement by dismantling tiles or bricks, removing mud plaster, preparing the surface of mud phaska to proper slope, relaying mud plaster gobri leaping and tiles or bricks, grouted in cement mortar 1:3 (1 cement : 3 fine sand) including replacing unserviceable tiles or bricks with new ones and disposal of unserviceable material to the dumping ground (the cost of the new tiles or brick excluded) within 50 metres lead. 38 Flush pointing with cement mortar 1:3 (1 cement : 3 fine sand) mixed with 2% of integral water proofing compound by weight of cement for flat tile bricks on top of mud phaska : 39 With F.P.S. brick tiles 40 Repair to leaking G.I.water supply pipe line by dismantling the G.I. pipe, replacing the GI pipe and fittings where required and restoring the water supply upto 15 metre height all complete as per direction of the Engineer-in-Charge.( GI pipes and fittings shall be paid for separetely). 41 Re-setting of existingaluminum door/window shutters , tightening of cleats etc. refixing of pivots or aluminium hinges or rubber gasket/floor spring/door fittingswherever required including steel screws etc. all complete 42 Repair to floor trap/P-trap etc. with neat cement slurry including mixing of water proofing solution to prevent leakage as per the direction of Engineer-in-Charge. 43 Removal of Plants like Pipal Plant etc. from the roofs,shafts and from other parts of the Building at all heights and removing its roots,And pouring solution of Chlorpyriphos E.C 20% in the root of plants and making good the same complete as per direction of Engineer-in-Charge(Girth not exceeding 10 cm) 44 Repairs to existing steel rolling shutters by dismantling the shutter,setting it right by removal of dents, tensioning of coil springs, greasing of side guides,straighting of main shafts etc. and refixing the shutters at its proper position and ensuring free operation of shutter all complete as per the directions of Engineer-in-Charge. 45 Water proofing Coating ontile terracing under solar panels placed at roofby using Sika Latex SBR or equivalentwith Cement sand mortar in ratio (1:1:2:2 = Sika Latex® SBR :Water : Cement : Fine sand)as per direction of Engineer-in-Charge with following procedure: Thoroughly pre-wet the prepared substrate. Keep the surface wet and do not allow to dry.Before application remove excess water e.g. with a clean sponge. The surface shall appear a dark matt appearance without glistening and surface pores and pits shall not contain water. Prepare the waterproofing coating as indicated above. Using a stiff clean brush spreadthe coating vigorously onto the substrate,forming a thin layerAfter 2 to 6 hours, apply the second coat in crosswise direction to first coat. 46 Disconnecting damaged overhead/terrace PVC water storage tank of any size from water supply line and removing from the terraceincluding shifting at ground level as per direction of Engineer-in- charge. 47 Taking out existing wooden door shutter, repair by cutting, painting etc. and refixing of repaired door shutters to existing door frames, including replacement of hinges with screws, etc. as required, all complete as per the direction of the Engineer-in-charge. 48 Terracecleaning including removal of rank vegetations,grass etc. and cleaning of connecting khurra and rodding of RWP to ensure smooth flow of rain water and disposalof rubbish upto 50m lead all complete as per direction of Engineer-in-Charge. 49 Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all loads including all lifts involved. 50 Providing the Plumbing services with Semi skilled fitter for attending day to day complaints on urgent basis like repair of water supply equipments and sanittary installations in the BSNL Compounds within Jalandhar and also attend the BSNL Civil Division Jalandhar office for cleaning, mopping the office, carrying office files etc.all as per the direction of E-I-C.The agency shall provide all necessary tools and plants,ladder and scaffolding wherever required including Mobile Phone and instructions to the worker for attending the complaints.(Nothing extra shall be paid on this account.The materials/fittings required shall be paid for separately). The services for payment are for one month i.e. Per Job Per Month. 51 Extra for providing plumbing services in the item No. 31 above foroutside the Jalandhar city i.e. in the BSNL buildings under the Jalandhar Business Area. 52 Providing the Carpenterservices with skilled Carpenter for attending day to day complaints on urgent basis like repair of doors,windows and chowkhats in the BSNL Compounds within Jalandhar Business Area as per the direction of E-I-C.The agency shall provide all necessary tools and plants,ladder and scaffolding wherever required including Mobile Phone and instructions to the worker for attending the complaints.(Nothing extra shall be paid on this account.The materials/fittings required shall be paid for separately). The services for payment are for one Day ie Per Job Per Day 53 Providing Beldar to assist Plumber / Carpenterfor attending day to day complaints in the BSNL Compounds within Jalandhar Business Area as per the direction of E-I-C. The services for payment are for one Day ie Per Job Per Day 54 Cleaning of chocked sewer line by diesel running vehicle mounting hydraulic operated high pressure suction cum jetting sewer cleaning machine fitted with pump having 4000 litres suction capacity and 6000 litres water jetting tank capacity including skilled operator,supervising engineer etc. for cleaning and partial desilting of manholes and dechocking of sewer lines. Dechocking and flushing of sewerline from one manhole to another by high pressure jetting system of 2200 PSI for sewer line from 150mm dia upto 300mm 55 Cleaning and desilting of gully trap chamber, including removal of rubbish mixed with earth etc. and disposal of same, all as per thedirection of Engineer-in-charge. 56 Cleaning of Manholes including taking out the sludge,rubbish and other forgien materials for smooth and free flow of sewage water all complete as per the direwction of E-I-C. 57 Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. 58 Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) 59 Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.. 60 In cement mortar 61 Providing and fixing white vitreous china water closet squatting pan (Indian type) 62 Orissa pattern W.C. pan of size 580x440 mm 63 Providing and fixing white vitreous china pedestal type (European type/ wash down type) water closet pan. 64 Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 65 Supplying the following items as and when required as per approved brand and approved manufacturer( ISI marked) complete as perdirection of Engineer-In-Charge. 66 P.V.C. low level Flushing Cistern10 litre capacity (In all colours as per direction of EIC) 67 White Plastic seat (solid) with lid, C.P. brass hinges and rubber buffers 68 Vitreous china flat back wash basin550 x 400mm 69 Flexible (coil shaped) PVC waste pipe for sink and washbasin 32 mm dia with length upto 700mm i/c PVC waste fittings. 70 Rectangular shape 453x357 mm Mirror with Plastic moulded frame 71 Brass face/spindlefor C.P. brass pillar cocks/ bib cocks/stop cocks etc. 72 CP stainless jali grating 73 100mm dia 74 Hydraulic door closer tubular type Aluminium section body 75 Aluminium hanging floor door stopper with twin rubber & stopper 76 Brass bib-cock 15 mm dia 77 Brass stop-cock 15 mm dia 78 CP bass bib cock confirm to IS:8931 79 15mm nominal bore 80 CP brass long body bib cock confirm to IS:8931 81 15mm nominal bore 82 CP brass angle valve confirm to IS:8931 83 15mm nominal bore 84 Ball valve (brass) of approved quality, High or low pressure, with plastic floats- 15 mm nomonal bore 85 Uplasticised PVC connection pipe with brass unions 86 45 cm length 87 15mm nominal bore 88 CP spray jet for european wc pan,15mm nominal bore 89 CP brass pillar cock (Heavy type) confirm to IS:8931 90 15mm nominal bore 91 G.I. pipes of Jindal/ Surya Prakash make for water supply 92 15mm dia nominal bore 93 20mm dia nominial bore 94 CPVC pipes of approved make for water supply including accessories. 95 25mm dia nominal bore 96 20mm dia nominial bore 97 PTMT bib cock 98 15mm nominal bore 99 PTMT stop cock 100 15mm nominal bore 101 PTMT pillar cock 102 15mm nominal bore 103 PTMT grating circular type 104 100mm nominal bore 105 PVC tank cover for all sizes of PVC tank 106 Aluminium Tower Bolts 107 200 x 10mm 108 150 x 10mm 109 Aluminium Handles 110 100mm 111 75mm 112 Aluminium Sliding Door bolts 113 200 x 16mm 114 4mm thick plywood BWP( commercial ) 115 Mild steel wire guage (galvanised) aperture 1.4 mm and 0.50 mm dia wire 116 PVC handle & ball cock for cistern with washer 117 Syphon set complete for PVC Cistern 118 20mmPTMT ball cock weight not less than 198gms with plastic ball 119 25mmPTMT ball cock weight not less than 440gms with plastic ball 120 Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg., for doors, including cost of cutting floors ,embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge. 121 With stainless steel cover plate minimum 1.25 mm thickness. 122 Providing and fixing Brass 100mm mortice latch and lock with 6 levers without pair of handles (best make of approved quality) for aluminium doors including necessary cutting and making good etc.complete. 123 Credit for old dismantled/unserviceable material: - 124 Brass bib cock/stop cock/ball valves/CP bibcock/CP stop cock,C.P angle cock,CP pillar cock,CP shower rose,brassgate valves, CP ring,CP brass towel rail etc. of all dia 125 Floor door spring machines 126 G.I. pipe 15mm nominal bore 127 G.I. pipe 20mm nominal bore 128 Hydraulic door closer
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
39.
Housing Urban and Rular Development #10191469 AOC
Furnishing Work Of Classrooms, Library And Laboratory, Equipments And Miscellaneous Work For The New University Campus Of Binod Bihari Mahato Koyalanchal University, Dhanbad- 1 Supplying Metal Exhaust Fan 300 mm Sweep-Supplying, erecting and testing of approved make 300 mm sweep Exhaust Fan heavy duty with mounting frame, blades AC 230-250 complete connection and including frame bolt/ Anchor hole fastners etc, complete finished of a as required. 2 Wall Demolition- Dismantling pucca brick or lime work including stacking serviceable materials in countable stacks within 15M. Lead and disposal of unserviceable materials with all leads all complete as per direction of E/I. 3 Taking down chaukhats in windows including stacking serviceable materials within 15M,. Lead and disposal of unserviceable materials with all leads all complete as per direction of E/I. 4 Taking down chaukhats in doors including stacking serviceable materials within 15M,. Lead and disposal of unserviceable materials with all leads all complete as per direction of E/I. 5 Taking sown chaukhats in windows including stacking serviceable materials within 15M,. Lead and disposal of unserviceable materials with all leads all complete as per direction of E/I. 6 Supplying, fitting and fixing 35mm thick solid core type decorative single leaf flush door shutter with both sides decorative veneered with black board core bended with high quality phenol formal dehydes synthetic resine of standard make with Aluminium fittings such as hinges, towerbolts, handle, cleat and sand blocks and taxes all complete as per building specification and direction of E/I. 7 Door Frame- Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge. Profile C - Fixing with adjustable lugs with split end tail to each jamb 8 Providing designation 125 mm thick reinforced designation 75A brick work in CM (1:4) in superstructure with approved quality of clean coarse sand of F.M. 2 to 25 including the cost of screening, carriage of materials, scaffolding , raking out joints to 15mm depth, curing, taxes and royalty (but excluding the cost of reinforcement) all complete as per building specification and direction of E/I. 9 Extra for providing and placing in position 2 Nos 6mm dia. M.S. barsat every third course of half brick masonry. 10 Providing 12mm cement plaster (1:6) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I. 11 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 12 Providing two coats of plastic emulsion paint of approved shade and make over a coat of cement primer over new surface including preparing plastered surface by rubbing smooth with pumice stone or fine sand paper, applying putty wherever required, scaffolding washing of floor and taxes all complete as per building specification and direction of E/I. 13 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size,approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement,mixed with matching pigment, epoxy touch ups, including rubbing, curing,moulding and polishing to edges to give high gloss finish etc. complete at all levels.-Granite stone slab colour black, Cherry/Ruby red-Area of slab over 0.50 sqm 14 Sink- Supplying fitting and fixing white glazed fires clay sink of approved make with overflow arrangements supported on C.I. Or R.S. Painted bracket 40mm. Dia C.P. Brass waste with C.P. Brass chain and rubber plug 40mm dia P.V.C. Waste pipe about 750mm long with brass coupling at one endand 15mm C.I. body brass spindle bib cock of approved quality of weight not less than 450grams including cutting wall and making good the same etc. all complete as per specification and direction of E/I. Size-600 mm x 450 mm x 250 mm ) 15 FULL HEIGHT WOODEN PARTITION WITH PARTLY GLAZING- Providing and fixing partitions made of 50 mm x 50 mm pine wood / 2nd class teak wood @ 600 mm c/c both ways with the help of Fasteners/Screws etc. to achieve desired strength. Providing & fixing Comm. grade 12 mm thick commercial Pty board on the frame on both the faces i/c exposed side edges of Frame & 1.0mm thk Laminate on both outer faces and exposed side edges of ply as per the directions. Partition shall also be provided with 8 mm thick clear float glass of approved size with Polished Edges of approved brands in Wooden Partition Openings as required, fixed from all four sides from both ways inside partition openings with 10mm.tk. T.W. beadings/12 mm thick MDF Board Lipping/D-Buttons of design as per approval and direction at site. Etching / Etching Film (50 Microns) is to be provided as per approved pattern on 8 mm thick clear float glass. All wooden exposed surfaces shall be melamine polished in approved shade and texture finished as per the directions and satisfaction of Engineer In charge, compelete.This work will 16 Frosted glass sheet of nominal thickness 4 mm- Providing and pasting frosted film on glass work including all materials tools, plants and labour complete as per the directions of the Engineer-in-charge. 17 Supply & laying of PVC insulated and sheathed 1.1 kv grade twin twisted 1.5 sqmm cu flexible wire for speaker. 18 Providing & installation 1.5 Tr. 5 Star split A.C (Inverter Type) I91391-part-1 19 Copper refregerant pipe-Providing & installation Copper Tube of size 5/8 for split ac unit 1/1.5/2/3 tr capacity including nitride rubber insulation 20 Providing & installation 5 KVA wall mounted automatic voltage stablizer from range 140 V to 280V 21 Providing & installation Drain Pipe for AC 22 Non Schedule 23 * PROVIDING AND SUPPLYING MODERN DESIGN RECEPTION DESK IN ENGINEERED WOOD MAKE THE PRODUCTS UTILE AND A DELIGHT.TIMELESS DESIGN THAT ELEVATES YOUR OFFICE SPACE STRUCTURE OF SPACIOUS RECEPTION DESK,TABLETOP OFFERS YOU A GENEROUS LOOK FOR WORK SURFACE USE PREMIUM QUALITY MATERIALS OVER ALL SIZE IS 1800 MM(L)X 600 MM(D)X 750 MM(H) WHICH GIVE MORE SURFACE AREA FOR WORK ,TABLE TOP MADE OF25MM THICK ALSO TABLE TOP BASED ON SIDE PANELS MADE 18MM THICK PRELAMINATED PARTICLE BOARD OF GRADE II TYPE III OF IS 12823/LATEST. * COMBINATION CONSTRUCTION OF RECEPTION DESK ABOVE TABLE TOP 18 MM THICK COUNTER TOP TO TABLE TOP HEIGHT IS @ 300MM ,OVERALL RECEPTION DESK HEIGHT IS @ 1050MM WITH COUNTER TOP,TABLE TOP MADE 25 MM THICK PRELAM PARTICLE BOARD WORK SURFACE WITH THE EXPOSED EDGES SHALL BE FINISHED WITH 2MM THICK PVC EDGE BINDING TAPE OF MATCHING COLOUR AND SHADE FIXED WITH HOT MELT GLUE.ALONG WITH 18MM THK ADDITIONAL MODESTY PANEL SIZE IS 1350 MM (L) X 700 MM (H) MADE BY EXCLUSIVE FROSTY WHITE COLOUR WITH EPIC DESIGN & LOOK.1 MOBILEPEDESTAL (2 DRAWERS + 1 FILING CABINET )SIZE IS 450 MM(L)X 450 MM(D)X 725 MM(H) IN PROVIDED WITH CENTRAL LOCKS FOR SECURITY AND HANDLES ARE PROVIDED FOR EASY OF OPENING & PEDESTALS MOVE ON NYLON CASTORS. * THREE LAYER PRELAMINATED PARTICLES BOARD(WOOD PRODUCT) OF GRADE II TYPE III OF IS 12823/LATEST 24 PROVIDING AND SUPPLYING * MEDIUM BACK 360° DEGRE REVOLVING CHAIR * ALL OVER SIZE IS : 580MM(L)X 670MM(D)X1110MM(H) ,*THE CHAIR MADE OF FULL UPHOLSTERY IN BLACK COLOUR .IT WILL COMES IN MATTE FINSIH IN CONTEMPORARY STYLE .DETAILS :* ARMS : AMREST IS HAVING TWO ADJUSTMENT HEIGHTS (UP & DOWN) .* USE OF PLY: 12 MM THICK HOT PRESSED BWR PLYWOOD(IS GRADE - 303 FOR SEAT AND BACK) .* SEAT: 40 ± 2 MM THICK POLYURETHANE FOAM WITH DENSITY 32 (±3) KG PER CU METER FOR BEST QUALITY CUSHIONING IN SEAT , * BACK : 40 ± 2 MM THICK POLYURETHANE FOAM WITH DENSITY 32 (±3) KG PER CU METER FOR BEST QUALITY CUSHIONING IN BACK . BACKREST SUPPORT FOAM DESIGN BASED ON SYMMETRICAL LUMBAR SUPPORT* MECHANISM : SINGLE LOCKING MECHANISM. SEAT MAXIMUM HEIGHT IS 580MM & MINIMUM HEIGHT IS 480MM & BACK HEIGHT FROM FLOOR MAXIMUM HEIGHT IS 1110MM & MINIMUM HEIGHT IS1010MM* GAS LIFT 100 MM TELESCOPIC HAUDRAULIC * BASE : 650MM NYLON BASE WITH SMOOTH CASTORS . 25 PROVIDING AND SUPPLYING 3 Seater Public Place Seating Chair of mildsteel with arm and backrest WITHOUT CUSHION,THREE SEATERTYPE WAITING AREA CHAIR - MATERIAL : STAINLESS STEEL SIZE 1820MM(L)X 690MM(D)X 790MM(H) COLOUR : SILVER/WEIGTH OF PRODUCT : 34 KG APPROX,* SUPPLYING AND PLACING IN POSITION OF A STAINLESS STEEL VISITOR BENCH OF SIZE IS 1820MM(L)X 690MM(D)X 790MM(H). THE COMPLETE STAINLESS STEEL BENCH HAS SEAT & BACK SINGLE SECTION. PER SEAT LENGTH IS @ 520 MM &SEATING HEIGHT IS @ 430 MM FROM GROUND . OWING TO THE SMOOTH FINISH, DURABILITY AND TENSILE STRENGTH BEAM STAINLESS STEEL MADE BY 1.6MM THICK.SEAT IS MADE BY 1.2MM THICK STAINLESS STEEL BORDER WITH CHROME PLATING FOR EVERY SEAT & BACK ; STAINLESS STEEL HANDLES CHROME PLATED & DIE PRESSED LEGS AT THE END OF CHAIRS.GROSS WEIGHT OF REGULAR 3-SEATER WILL BE 34 KG.THE STEEL GRADE 202 HIGH YIELD STRENGTH AS PER IS:513 & IS:304 GRADE. 26 Supplying of Portrait/Landscape Not applicable Fabric Pin Up Notice Boards(Fabric Pin Up Notice Boards 3 X 6 FT GREEN),Specification-Width of Board in mm:900 mm,Colour(Front/ Display layer):Green,Height of Board in mm:1800mm,Rear panel material of Board:Laminated sheet,Overall pinability depth ofBoard in mm:9 millimeter,Core material thickness inmm:9 millimeter 27 PROVIDING AND SUPPLYING COLLEGE DESK TOMKINS MATERIAL : PRELAMINATED PARTICLE BOARD WITH M.S BASE UNIT SIZE : 590 MM(L) X 1090 MM(D) X 830 MM(H) PER SEAT SIZE- 590 MM X 375 MM X 450 MM/ONE SEATER DESK SIZE :1090 MM(L) X830 MM(H) COLOUR : AVAILABLE ON REQUEST/FINISH : EPOXY POLYESTER ,* PROVIDING & SUPPLYING TWO SEATER COLLEGE DESK TOMKINS COMBINATION OF THREE ROWS FIRST , MIDDLE AND LAST SCRATCHPROOF EASY WIPE TOP / DURABLE ,STRONG & SAFE,UNDERSTRACTURE MADE OF MAIN FRAME MDE OF CRCA POWDER COATED IS GRAD:304 M.S BLACK POWDER COATED TO THE THICKNESS 50-60 MICRONS(+/-5 MICRON) EPOXY POLYESTER COATING.* TABLE TOP & MODESTY PANNEL MADE IN 18MM THICK PRELAMINATED PARTICAL BOARD OF GRADE II TYPE III OF IS 12823/LATEST WITH MACHINE PRESSED EXPOSED EDGES SHALL BE FINISHED WITH 2MM THICK EDGE BINDING TAPE OF MATCHING COLOUR AND SHADE FIXEDDULY PASTED WITH THE ASSISTANCE OF EDGE BANDING MACHINE AT 200 DEGREE CELSIUS.CHAIR WITH GAS LIFT ,A). BACK FRAME: 1.2MM COLD ROLLED STEEL/B). BACK BOARD: 10MM PLYWOOD, NO CUSHION C). SEAT BOARD: 15MM PLYWOOD, NO CUSHION/D). TIP-UP SYSTEM: SPRING MECHANISM E). 2. LEG: COLD-ROLLED STEEL, FIXING ON THE FLOOR BY SCREWS, 80 X 35 X 1.5MM THICK OVAL TUBE, BLACK POWDER SPRAYING.* THREE LAYER PRELAMINATED PARTICLES BOARD ( WOOD PRODUCT ) OF GRADE II TYPE III OF IS 12823/LATEST 28 Supplying of Material & Subtype Engineered Wood Table Top Material Engineered Wood Finish Matte Colour & Colour Family Brown - Classic Walnut Dimension (W)550mm X (D)550mm X (H)1200mm Size Compact Assembly Type Knock Down (Obelisk), 29 Suppling of Writing Board ( 4x10 Non-Magnetic) of material Top Surface materials (Used for white boardsurface)-Porcelain,Top surface material thickness -0.7 mm to 0.8 mm,Frame material -Anodized extruded aluminum alloy hollow section conforming to IS 733 (With latest amendment),Frame wall thickness-1.2 mm,Frame section front -20 mm,Frame section side -16 mm,Core material-MDF board grade-I conforming to IS 12406 (with latest amendment),Core material thickness -9 mm as per Department incharge 30 Supplying of 14 SEATER U -* PROVIDING & SUPPLYING U - SHAPE MODERN DESIGN CONFERENCE TABLE & IN BETWEEN U SHAPE TABLE TOP LENGTH IS @ 8850 MM, TABLETOP OFFERS YOU A GENEROUS WORKSPACE,DESK PRIMARY WORK SURFACE USE PREMIUM QUALITY MATERIALS OVER ALL SIZE IS 8850 MM(L)X 600MM(D)X 750MM(H) TABLE TOP MADE OF 36MM THICK WHICH GIVE MORE SURFACE AREA FOR WORK ,MACHINE MADE MODULAR FURNITURE MADE PRELAMINATED PARTICLE BOARD OF GRADE II TYPE III OF IS 12823/LATEST, * CONSTRUCTION PROVISION OF CONFERENCE TABLETOP SUPPORTED WITH 18MM THICK SIDE PANNELS IN BROWN-BLACK OAK COLOUR MADE BY PRELAMINATED PARTICLE BOARD AND BELOW THE TOP 18MM THICK PRELAM PARTICLE BOARD MODESTY PANEL.OUR WORK SURFACE FURNITURE IS FINISHED WITH EXPOSED EDGES SHALL BE FINISHED WITH 2MM THICK EDGE BINDING TAPE OF MATCHING COLOUR AND SHADE,FIXED WITH HOT MELT GLUE. * THREE LAYER PRELAMINATED PARTICLES BOARD(WOOD PRODUCT) OF GRADE II TYPE III OF IS 12823/LATEST, 31 Supplying of * HIGH BACK 360° DEGRE REVOLVING CHAIR SKU : MARVEL/HB/ECO ,* ALL OVER SIZE IS : 595MM(L)X 670MM(D)X1380MM(H) ,*THE CHAIR MADE OF FULL MESH IN BLACK COLOUR .IT WILL COMES IN MATTE FINSIH ABOUT STYLE TYPE IS MODREN.DETAILS :* * ARMS : FIXED PP ARMSREST .* USE OF PLY: 12 MM THICK HOT PRESSED BWR PLYWOOD(IS GRADE - 303 FOR SEAT).* SEAT: 40 ± 2 MM THICK POLYURETHANE FOAM WITH DENSITY 32 (±3) KG PER CU METER FOR BEST QUALITY CUSHIONING IN SEAT , * BACK :FRAME OF DESIGN SHALLBE CURVEDMADE OF TWO PIECES INJECTION MOULDED FRAME COVER WITH MESH .BACKREST SUPPORTADJUSTABLE LUMBAR SUPPORT* MECHANISM : SINGLE LOCKING MECHANISM . * ONLY SEAT SIZE IS 670MM(L)X 595MM(D)X470-570MM(H) , SEAT MAXIMUM HEIGHT IS 570MM & MINIMUM HEIGHT IS 470MM & BACK MAX HEIGHT IS @ 1380MM .* GAS LIFT 100 MM TELESCOPIC HAUDRAULIC * BASE : NYLON BASE IS 620MM PITCH CENTER DIA (660MM WITH CASTORS) . 32 Supplying ofMEDIUM BACK 360° DEGRE REVOLVING CHAIR * ALL OVER SIZE IS : 595MM(L)X 670MM(D)X1125MM(H) ,*THE CHAIR MADE OF FULL MESH IN BLACK COLOUR .IT WILL COMES IN MATTE FINSIH ABOUT STYLE TYPE IS MODREN.DETAILS :* * ARMS : FIXED PP ARMSREST .* USE OF PLY: 12 MM THICK HOT PRESSED BWR PLYWOOD(IS GRADE - 303 FOR SEAT).* SEAT: 40 ± 2 MM THICK POLYURETHANE FOAM WITH DENSITY 32 (±3) KG PER CU METER FOR BEST QUALITY CUSHIONING IN SEAT , * BACK :FRAME OF DESIGN SHALLBE CURVEDMADE OF TWO PIECES INJECTION MOULDED FRAME COVER WITH MESH .BACKREST SUPPORTADJUSTABLE LUMBAR SUPPORT* MECHANISM : SINGLE LOCKING MECHANISM .* ONLY SEAT SIZE IS 670MM(L)X 595MM(D)X470-570MM(H) ,SEAT MAXIMUM HEIGHT IS 570MM & MINIMUM HEIGHT IS 470MM & BACK MAX HEIGHT IS @ 1125MM .* GAS LIFT 100 MM TELESCOPIC HAUDRAULIC * BASE : NYLON BASE IS 620MM PITCH CENTER DIA (660MM WITH CASTORS) . 33 Supplying of Tte Mild Steel Pipe of diameter 19 mm and wall thickness 16gauge. Classroom Chairs, tte,Thickness-2mm to 45mm,Material-Mild Steel Weight-Depends upon the size,Outside Diameter-0.80 Inch to 36 Inch 34 Supplying of 1-Bay Sprocket Chain Drive Mechanism MobileStorage Compactors,Material-Mild Steel Product Type-1 Bay,Height -7 ft,Storage Capacity-50-80 kg Usage/Application office, Home, Hospital, Store Room, Warehouse 35 Supplying of -- Movable File StorageSystem (Compactor) 1-Bay Mechnized Drive Type(COMPACTOR 2 ( 04 BODY)) 36 Supplying of Methodex MS1-6MCMETHODEX(Methodex MS1-6MC),Accutec Mobile Storage System,Material SS,Usage/Application-Warehouse Height-8-10 Feet,No of Layers-5 37 Supplying of : METAL STORAGE OF SIZE 900MM(L)X 450MM(D)X 1980MM(H) BODY MADE OUT IN 22 GAGUE(0.8MM) & DOOR 19 GAGUE(1 MM) CRCA SHEET. 4 ADJUSTABLE SHELVE IN 22 GAGUE(0.8MM) & PEDESTAL 18 GAGUE 1.2 MM CRCA SHEET. HAVING FOUR SHELVES MAKING FIVE COMPARTMENT, UNIFORMLY DISTRIBUTED LOAD CAPACITY OF EACH SHELF SHALL BE 60 KG MAXIMUM,FITTED WITH MS BODY LOCK & HANDLE. FINISHING WITH EPOXY POLYESTER POWDER COATED TO THE THICKNESS 50-60 MICRONS(+/-5 MICRON)IN COLOR GREY-LIGHT GREY. 38 Supplying of : PREMIUM SUITESDIRECTOR TABLE STRUCTURE OF L-SHAPED DESK . PRIMARY WORK SURFACE OVER ALL SIZE IS 2400MM(L)X 2330MM(D)X 770MM(H) 45MM THICK TABLE TOP MADE OF PRELAMINATED PARTICLE BOARD WORK SURFACE WITH RICH CHERRY FINISH SAME MATCHING EDGE BANDING MADE OF SAME RED CHERRY P.U POLISH.MODESTY IS DESIGNED WITH LEATHER PATCH.SIDE PANNEL IS MADE OF 36MM THICK . * PROVISION OF SIDE UNIT OF SIZE IS 1200MM(L)X 595MM(D)X 770MM(H) ,(COMBINATION CONSTRUCTION ON TABLE TOP WIRE MANAGEMENT 2 HOLE WITH SS GROOMENT & 1 HOLE WITH PVC GROOMENT ON TOP SIDE UNIT. BELOW TABLE TOP ONE KEYBOARD TRAY,IN SIDE UNIT BELOW THE TOP 1 KEY BOARD TRAY,1 OPEN BOX FILE ,1 DRAWER + 1 OPEANABLE DOOR SHELVE. * FIXED PEDESTAL OF SIZE450MM(L)X 400MM(D)X 690MM(H) , HAVING 3 EQUAL DRAWERS IN PROVIDED WITH CETNRAL LOCK FOR SECURITY AND HANDLES ARE PROVIDED FOR EASY OF OPENING. OVERALL CONSTRUCTION OF PEDESTAL IS 18 MM ALONG WITH FECIA OF DRAWERS. * ALL THE MDF BORAD ARE IS-14587-1998 WITH CONFIRM TO DIN 68861.ISO 9001- 2015 QUALITY CERTIFICATION CONFIRMING TO ASTM D 4499 STANDARDS FOR VISCOSITY AND THERMAL STABILITY . 39 Supplying of* HIGH BACK 360° DEGRE REVOLVING CHAIR * ALL OVER SIZE IS : 590MM(L)X 505MM(D)X1280MM(H) , *THE CHAIR MADE OF FULL LEATHERETTE IN BLACK COLOUR . IT WILL COMES IN MATTE BLACK FINISH FINSIH IN CONTEMPORARY STYLE . DETAILS :* ARMS :CHROMEFINISH ARMS WITH PU PADDING . * USE OF PLY: 12 MM THICK HOT PRESSED BWR PLYWOOD(IS GRADE - 303 FOR SEAT AND BACK) . * SEAT: 40 ± 2 MM THICK POLYURETHANE FOAM WITH DENSITY 32 (±3) KG PER CU METER FOR BEST QUALITY CUSHIONING IN SEAT , * BACK : 40 ± 2 MM THICK POLYURETHANE FOAM WITH DENSITY 32 (±3) KG PER CU METER FOR BEST QUALITY CUSHIONING IN BACK . BACKREST SUPPORT FOAM DESIGN BASED ON SYMMETRICAL LUMBAR SUPPORT * MECHANISM : KNEE TILT MECHANISM . * ONLY SEAT SIZE IS 505MM(L)X 505MM(D)X610MM(H) & THE BACK SIZE IS 590MM(L)X 710MM(H) SEAT MAXIMUM HEIGHT IS 610MM & MINIMUM HEIGHT IS 510MM & BACK HEIGHT FROM FLOOR MAXIMUM HEIGHT IS 1280MM & MINIMUM HEIGHT IS1180MM * GAS LIFT 100 MM TELESCOPIC HAUDRAULIC * BASE : 650 MM CHROME BASE WITH SMOOTH CASTORS . 40 Supplying of* FIX CANTILEVER CHAIR * ALL OVER SIZE IS : 570MM(L)X 500MM(D)X940MM(H) , *THE CHAIR MADE OF FULL LEATHERETTE IN BLACK COLOUR . IT WILL COMES IN MATTE FINSIH IN CONTEMPORARY STYLE . DETAILS : * ARMS : PADDED ARMREST. * USE OF PLY: SEAT & BACK PLYWOOD MADE OF 12 MM HOT PRESSED. * SEAT: 40 ± 2 MM THICK POLYURETHANE FOAM WITH DENSITY 32 (±3) KG PER CU METER FOR BEST QUALITY CUSHIONING IN SEAT , * BACK : 40 ± 2 MM THICK POLYURETHANE FOAM WITH DENSITY 32 (±3) KG PER CU METER FOR BEST QUALITY CUSHIONING IN BACK . BACKREST SUPPORT FOAM DESIGN BASED ON SYMMETRICAL LUMBAR SUPPORT * ONLY SEAT SIZE IS 570MM(L)X 500MM(D)X475MM(H) SEAT HEIGHT IS @ 940MM & BACK HEIGHT IS @ 475MM . * FIXED CANTILEVER CHAIR . * BASE : CHROME FINISH TUBLAR FRAME OF CANTILEVER TYPE . 41 * SUPPLYING AND PLACING FIVE SEATER (3+1+1) EXCLUSIVE PREMIUM LEATHERETTE MODERNIST CLASSIC DESIGN LOUNGE SEATING SOFA SIZE IS 3 SEATER- 1905MM(L) X890MM(D)X 870MM(H)SOFA SIZE IS 1 SEATER -(W)960mm X (D)890mm X (H)870mm ,WITH KILN-DRIED WOOD FRAMING MAKES IT WARP AND SCRATCH RESISTANT,COMFORTABLE SEAT DEPTH & HEIGHT DESIGNED KEEPING MODERN INDIAN LIFESTYLE IN MIND,WRAPPED IN BUTTERY-SOFT PREMIUM LEATHERETTE, THE PANELLED BACK AND CUSHIONED ARMRESTS ENCOURAGE LOUNGING,DESIGNED WITH MODERNITY & ELEGANCE, CHOOSE THE OPTION THAT SUITS YOUR HOME. * COMBINATION CONSTRUCTION STRUCTURE ARE MADE INMOISTURE CONTENT SHALL BE LESS THAN (10-12)%. THICKNESS OF PLYWOOD USED (MM) SHALL BE 12 MM GRADE IS 303 INDIAN STANDARD FOR COMMERCIAL (COMMON) AND MOISTURE PROOF PLYWOOD (TENTATIVE).UNDERSTRUCTURE FRAME SHALL BE CONSTRUCTED FROM 18 MM THICK KILN-DRIED GERMAN BEECH WOOD FRAMING IS HIGHLY DURABLE. THE COMPLETE STRUCTURE SHALL BE COVERED BY P.U.FOAM FIXED WITH ADHESIVE GLUE ,THE FRAME SHALL BE PADDED WITH HIGH RESILIENCE POLYURETHANE FOAM HAVING 28 +/- 5 DENSITY IN SEAT IT SHALL BE STACK FOAM OF 50MM THIK,40MM THICK BACK FOAM HAVING 20 +/- 5 DENSITY FOAM USED ,THERE SHALL BE CUSHION ARM 40MM THICK PROVIDED PADDED WITH HIGH RESILIENCE POLYURETHANE FOAM HAVING DENSITY 20 +/- 5. THE COMPLETE STACK FOAM STRUCTURE SHALL BE COVERED WITH PREMIUM LEATHERETTE IN BLACK-EERIE BLACK-COFFEE BROWN,BROWN-BURNT UMBER COLOUR, IT COMPLEMENTS THE MODISH LEGS ARE MADE BY ROUND SHAPE IN PVC MATERIAL. 42 Supplying of Material & Subtype Solid Wood - Beech Wood Table Top Material Clear Glass,Frame Material Solid Wood Leg Material Solid Wood,Finish Matte Colour & Colour Family Brown - Walnut,Dimension (W)1130mm X (D)630mm X (H)410mm,Number Of Recliners 1 Number Of Reclining Positions 3,Size Standard (HOPPER/CT), 43 Supplying of6 SEATER Rectangular MEETING TABLE DURIAN MODEL SMART/CON/6FT MADE OF PRELAMINATED PARTICLE BOARD WITHSLANTLEGS50X50 MM MS UNDERSTRUCTURE IN POWDER COATING 2TOP MADE OF25MMTHICK PRELAMINATED PARTICLE BOARD IN FROSTY WHITE COLOR WITH MAIN TABLE SIZE1800MM(L)X 1050MM(D)X 750MM(H) (SMART/CON/6FT/A), 44 SUPPLYING & PROVIDING CAFETERIA CHAIR SIZE IS 381MM(L)X 419MM(D)X839MM(H) A COMBINATION OF SYNTHETIC FIBER WITH STAINLESS STEEL MAKE THE PRODUCTS UTILE AND A DELIGHT, THE COMPLETE STRUCTURE SHALL BE MADE UP OF 20% GLASS FILLED BLOW MOLDED HIGH-DENSITY POLYETHYLENE ANDIS,THE FRAME STRUCTURE SHALL BE SUPPORTED BY ( 2 STRAIGHT + 2 SLANT ) FOUR LEGS.THE TUBULAR WELDED FRAME IS MADE FROM DIA2.22 +/- 0.03CMX 0.12+/- 0.0128 CM AND 3.5+/- 0.03 CM X 0.12+/- 0.0128 AM STAINLESS STEEL 202 GRADE TUBE & THE TUBE ARE BUFF POLISHED TO GIVE SHINY FINISH.SEAT AND IN BACK GIVEN HANDLE TO HOLDARE MADE OF INJECTION MOULDED HIGH IMPACT STRENGTH POLYPROPYLENE POLYMER COMPOUND WITH INDOOR GRADE UV RESISTANCE AND PRESSED FITTED WITH LEGS.THE CHAIR IS EASY TO STORE WHEN NOT IN USE, SINCE YOU CAN STACK UP TO 6 CHAIRS ON TOP OF EACH OTHER. (COCO/SUR). 45 SUPPLING OF METAL STORAGE OF SIZE 900MM(L)X 450MM(D)X 1830MM(H) BODY MADE OUT IN 22 GAGUE(0.8MM) & DOOR 19 GAGUE(1 MM) CRCA SHEET. 4 ADJUSTABLE SHELVE IN 22 GAGUE(0.8MM) & PEDESTAL 18 GAGUE 1.2 MM CRCA SHEET.HAVING FOUR SHELVES MAKING FIVE COMPARTMENT, FITTED WITH MS BODY LOCK & HANDLE. WITH 2 NUMBERS OF GLASS DOOR SHUTTERS , THE GLASS USED SHALL BE 4MM THICK CLEAR. UNIFORMLY DISTRIBUTED LOAD CAPACITY OF EACH SHELF SHALL BE 30 KG MAXIMUM.EACHRACKSHALLBEPROVIDEDWITHSTIFFENERATBOTTOMFOR STRENGTH.THE ENTIREBODYPANELAND SHELF SHALLBEMADEOF HIGHYIELD STRENGTH,THE COMPLETE STEEL STRUCTURE SHALL BE CONSTRUCTED BY WELDING AND PROVIDE FINISHING WITH EPOXY POLYESTER POWDER COATED TO THE THICKNESS 50-60 MICRONS(+/-5 MICRON)IN COLOR GREY-LIGHT GREY 46 SUPPLING OF DIRECTOR DESKDIRECTOR TABLE STRUCTURE OF L SHAPED DESK .PRIMARY WORK SURFACE OVER ALL SIZE IS 1500MM(L)X 750MM(D)X 750MM(H) 36MM THICK TABLE TOP MADE OF PRELAMINATED PARTICLE BOARD WORK SURFACE WITHWENGE FINISH, USING HOT MELT GLUE TO FIXING 2MM THICK PVC EDGE BANDING MADE OF SAME MATTE FINISH. SIDE PANNEL IS MADE OF 25MM THICK.*PROVISION OF SIDE RUNNER OF SIZE IS 750MM(L)X 450MM(D)X 760MM(H) ,( CONSTRUCTION IS FROM RIGHT SIDE OF SIDE UNIT TOP BASED ON FIXED PEDESTAL WITH SS STUD OF GRADE 304, ON TABLE TOP PVC GROMENT HOLEFOR WIRE MANAGEMENT .*FIXED PEDESTAL OF SIZE450MM(L)X 450MM(D)X 650MM(H) PER DRAWER HEIGHT IS @ 136MM, FILLING DRAWER HEIGHT IS @ 300MM HAVING (2 EQUAL DRAWERS + 1 FILLING DRAWER) IN PROVIDED WITH CETNRAL LOCK FOR SECURITY AND HANDLES ARE PROVIDED FOR EASY OF OPENING.OVERALL CONSTRUCTION OF PEDESTAL IS 18 MM ALONG WITH FECIA OF DRAWERS. *THREE LAYER PRELAMINATED PARTICLES BOARD(WOOD PRODUCT) OF GRADE II TYPE III OF IS 12823/LATEST , 47 SUPPLING OF* CANTILEVER CHAIR SKU : 70011/CN/A, * ALL OVER SIZE IS : 590MM(L)X 490MM(D)X980MM(H) , *THE CHAIR MADE OF FULL FABRIC INBLACK COLOUR . IT WILL COMES INFINSIH IN CONTEMPORARY STYLE . DETAILS :* ARMS : FIXED ARMS P.P. CONNECTED WITH SEAT AND BACK .* USE OF PLY: 12 MM THICK HOT PRESSED BWR PLYWOOD(IS GRADE - 303 FOR SEAT AND BACK) .* SEAT: 40 ± 2 MM THICK POLYURETHANE FOAM WITH DENSITY 32(±3) KG PER CU METER FOR BEST QUALITY CUSHIONING IN SEAT , * BACK : 40 ± 2 MM THICK POLYURETHANE FOAM WITH DENSITY 32 (±3) KG PER CU METER FOR BEST QUALITY CUSHIONING IN BACK . BACKREST SUPPORT FOAM DESIGN BASED ON SYMMETRICAL LUMBAR SUPPORT* BASE : M.S POWDER COATED TUBLAR FRAME OF CATILEVER TYPE . THE SELLER / COMPANY SHOULD BE ISO 9001:2015, ISO 50001:2018, ISO 14001:2015, ISO 45001:2018 CERTIFICATES OF THE MANUFACTURER CERTIFIED BY NATIONAL ACCREDITATION BOARD OF CERTIFYING BODIES, IGBC, SEDEX, GREEN PRO, AIOTA, INDIAN DESIGN MARK, FSC CERTIFICATE. 48 SUPPLING OF OFFICE DESKDESK STRUCTURE OF L SHAPED DESK . PRIMARY WORK SURFACE OVER ALL SIZE IS 1500MM(L)X 600MM(D)X 750MM(H) 25MM THICK TABLE TOP MADE OF PRELAMINATED PARTICLE BOARD WORK SURFACE WITH THE EXPOSED EDGES SHALL BE FINISHED WITH 2MM THICK EDGE BINDING TAPE OF MATCHING COLOUR AND SHADE WITH THE HOT MELT GLUE . MODESTY PANNEL 18MADE OF MM THICK . *PROVISION OF SIDE UNIT OF SIZE IS 900MM(L)X 450MM(D)X 750MM(H) ,(COMBINATION CONSTRUCTION WIRE MANAGEMENT HOLE WITH PVC GROOMENT ON TABLE TOP, LEFT SIDE TABLE TOP BASED ON A 18MM THICK SIDE PANNEL ENGINEERED WOOD & FROM RIGHT SIDE UNIT HAVE 2 SLIDING DOOR + 1 FIXED SHELVE . *SIDE UNIT SIZE900MM(L)X 450MM(D)X 750MM(H), IN PROVIDED WITH LOCK FOR SECURITY AND HANDLES ARE PROVIDED FOR EASY OF OPENING. OVERALL CONSTRUCTION OF SIDE UNIT IS 18MM THICK ALONG WITH FECIA OF SLIDDING SHUTTERS. *THREE LAYER PRELAMINATED PARTICLES BOARD(WOOD PRODUCT) OF GRADE II TYPE III OF IS 12823/LATEST . 49 SUPPLING OF * FIX CANTILEVER ,* ALL OVER SIZE IS : 595MM(L)X 510MM(D)X875MM(H) ,*THE CHAIR MADE OF FULL LEATHERETTE IN BLACK COLOUR .IT WILL COMES IN MATTE FINSIH IN CONTEMPORARY STYLE .DETAILS :* ARMS : PADDED ARMREST.* USE OF PLY: 12 MM THICK HOT PRESSED BWR PLYWOOD(IS GRADE - 303 FOR SEAT AND BACK) .* SEAT: 40 ± 2 MM THICK POLYURETHANE FOAM WITH DENSITY 32 (±3) KG PER CU METER FOR BEST QUALITY CUSHIONING IN SEAT , * BACK : 40 ± 2 MM THICK POLYURETHANE FOAM WITH DENSITY 32 (±3) KG PER CU METER FOR BEST QUALITY CUSHIONING IN BACK . BACKREST SUPPORT FOAM DESIGN BASED ON SYMMETRICAL LUMBAR SUPPORT* ONLY SEAT SIZE IS 500MM(L)X 510MM(D)X455 MM(H) & THE BACK SIZE IS 440MM(L)X 595MM(H) , BACK HEIGHT IS @ 440MM .* BASE : 4 LEGS METAL POWDER COATED* THE SELLER / COMPANY SHOULD BE ISO 9001:2015, ISO 50001:2018, ISO 14001:2015, ISO 45001:2018 CERTIFICATES OF THE MANUFACTURER CERTIFIED BY NATIONAL ACCREDITATION BOARD OF CERTIFYING BODIES, IGBC, SEDEX, GREEN PRO, AIOTA, INDIAN DESIGN MARK, FSC CERTIFICATE. THE BIDDER SHOULD BE A MEMBER OF BIFMA AND AT LEAST TWO PRODUCTS OF THE OEM SHOULD BE CERTIFIED AS BIFMA COMPLIANT AND AN OFFICIAL PRODUCT OFFICIAL LINK/SCREENSHOT OF THE PRODUCT LISTING MUST BE PROVIDED FROM WWW.BIFMA.ORG WARRANTY-5 YEARS MAKE-DURIAN /GODREJ/FEATHERLITE 50 * PROVIDING AND SUPPLYING PENTA WORKSTATIONLSHAPE SINGLE SEATER UNIT NON SHARING IN COMPLETELY KNOCK DOWN CONDITIONS WITH AN OVERALL SIZE 1500MM(L)X 600MM(D)X 1200MM(H) THAT IS TO BE ASSEMBLED AT SITE. THE WORKTOPSHALLHAVETHESIZE1490MM-1490MM (L) x 592(D) MADEUPOF25MMTHICKPRE- LAMINATED PARTICLE BOARD OF GRADE II TYPE III OF IS 12823/LATEST . OF IS LEVEL WITH APPROVED LAMINATE AND FINISH AS PER APPROVED SHADE. * THE PROFILE OF THE TOP SHALL BE IN RECTANGLE SHAPE AND THE EDGES SHALL BE SEALEDWITH 2MM THICK THIN STRIP OF IMPERMEABLEPVCTHAT IS CUT TO FIT THE SIZE OF BOARD PANEL AND DULY PASTED WITH THE ASSISTANCE OF EDGE BANDING MACHINE AT 200 DEGREE CELSIUS. * THE TOP TRIM, TOP BAR, MID BAR, VERTICAL BAR, RACEWAY, SKIRTING SHALL BE MADE UP OF ALUMINIUM EXTRUSIONS (PRE-TREATED)AND DULY POWDER COATED WITH POLYESTER POWDER COATING 40P-60PTHICK . THE TRIMS SHALL HAVE THE SIZE 67MM X 19MM WITH 1.5MMTHICKCOVERED WITH DIE CAST END CAPS ON JOINTS 2 WAYS,3 WAYS& 4 WAYS(L-COVERFORCORNER,T-COVERFORMIDDLESECTIONWHEREVER REQUIRED).THEALUMINIUMRACEWAYSHALLBESITUATEDBELOWTHEWORKTOPWITHAN OVERALLSIZE149MM(H)X60MM(D)WITH1.4MMCOVERTHICKNESSAND2MMBACK THICKNESS AS PER REQUIREMENT OF INLAYING THE ELECTRICAL MANAGEMENT AND CARRYING THE WIRE HORIZONTALLY. *THE EXPOSED VERTICAL AND HORIZONTALFACES OF THE FRAMES SHALL BE SNAPFITTEDWITHTRIMS.THERESHALLBESOFT-BOARD(WITHFABRIC)ANDMARKERBOARD PROVIDED AT FRONT OF THE USER. LAMINATED TOP TILE AND BOTTOM TILE SHALL BE SITUATED AT BOTH SIDES OF THE USER AND BELOW THE WORK TOP RESPECTIVELY. THE PARTITION SHALL HAVE CONCEALED WIRE MANAGEMENT CAPABILITIES AND SHOULD BE ENGAGED FOR RESPONSIVE AND SAFE OPERATIONSOF POWER,TELECOMMUNICATIONSANDDATA(LAN)AND HASSEPARATE COMPONENTS FOR ELECTRICAL, DATA AND TELEPHONE CABLES HAVING ADEQUATE CAPABILITY OF BOTH THE VERTICAL AND HORIZONTAL WIRE MOVEMENTS.SLOTS/CUT-OUTS SHOULD BE GIVEN ON RACEWAYSTOFIXALLELECTRICALANDDATAPOINTS.SINGLESIDEDPVCWIRE MANAGER SHOULDBE ENCLOSEDATTABLETOP.ADJUSTABLE LEVELLERSHOE SHALL BE PROVIDED AT BOTTOM OF THE PARTITION TO AVOID SCRATCHESON THE FLOOR.PARTICLE BOARD OF GRADE II OFISLEVEL. * THREE LAYER PRELAMINATED PARTICLES BOARD (WOOD PRODUCT) OF GRADE II TYPE III OF IS 12823/LATEST .* THE SELLER / COMPANY SHOULD BE ISO 9001:2015, ISO 50001:2018, ISO 14001:2015, ISO 45001:2018 CERTIFICATES OF THE MANUFACTURER CERTIFIED BY NATIONAL ACCREDITATION BOARD OF CERTIFYING BODIES, IGBC, SEDEX, GREEN PRO, AIOTA, INDIAN DESIGN MARK, FSC CERTIFICATE. THE BIDDER SHOULD BE A MEMBER OF BIFMA AND AT LEAST TWO PRODUCTS OF THE OEM SHOULD BE CERTIFIED AS BIFMA COMPLIANT AND AN OFFICIAL PRODUCT OFFICIAL LINK/SCREENSHOT OF THE PRODUCT LISTING MUST BE PROVIDED FROM WWW.BIFMA.ORG WARRANTY-5 YEARS MAKE-DURIAN /GODREJ/FEATHERLITE 51 PROVIDING & SUPPLYINGFIXING OF TWO SEATER SCHOOL DESK WITH SHELF/STORAGE UNDER DESK WHICH ONE MADE BY CAST IRON,DESK TOP MADE BY 18MM THICK PRELAMINATED PARTICAL BOARD OF GRADE II TYPE III OF IS 12823/LATEST,TWO SEATER CLASSROOM DESK CUM BENCH, TOTAL SIZE OF BENCH : 1050MM(L)X 950MM(D)X 760MM(H) DESK SIZE : 1050MM (W) X 400MM (D) X 760MM (H) BENCH SIZE : 1050MM (W) X 310MM (D) X 390 / 760MM (H) BACK SIZE : 1050MM (W) X 150 MM (H),TABLE TOP SHALL BE POLYPROPYLENE CO POLYMER (PPCP).BANDING UNDER STRUCTURE-BLACK 9005 ERW PIPE (AS PER IS:7138) : 25X25X1.2MM SQUARE MS PIPE, OF THICKNESS 1.2MM IN BLACK EPOXY POLYESTER POWDER COATED TO THE THICKNESS 50-60 MICRONS(+/-5 MICRON) AT BASE WITH PLASTIC CAPS MADE OF PP COPOLYMER (3530 GRADE) ARE ALSO PROVIDED ON THE REAR FRAMES ADDING MORE AESTHETIC VALUE TO THE PRODUCT. * ADDITIONAL HORIZONTAL SUPPORTS OF M.S. C SECTIONS OF 1.5MM THICK ARE PROVIDED BELOW THE DESK & SEAT.SHELF: 0.8MM THICK POWDER COATED M.S. SHEET BELOW THE DESK & HOOKS ON EITHER SIDE OF DESK IN M.S. ROD OF DIA 6MM.TOP,SEAT AND BACK PANEL: 18MM THICK PRE LAMINATED BOARD WITH MACHINE PRESSED EXPOSED EDGES SHALL BE FINISHED WITH 2MM THICK EDGE BINDING TAPE OF MATCHING COLOUR AND SHADE FIXEDDULY PASTED WITH THE ASSISTANCE OF EDGE BANDING MACHINE AT 200 DEGREE CELSIUS. * THREE LAYER PRELAMINATED PARTICLES BOARD ( WOOD PRODUCT ) OF GRADE II TYPE III OF IS 12823/LATEST.* 52 Suplying of Laboratory Steel Furniture Sidebench with rack and table top of specification,Size of side benches/Island benches (LxWxH):1800 mm X 1800 mm X 900 mm,Type of Frame for installation of bench:C type frame,C Type Fixed Under Bench Cabinet size:500 mm x 500 mm x 540 mm (having one door, one drawer and one adjustable/removable shelf) 53 Supplying of Laboratory Steel Furniture Island bench with table top Size of side benches/Island benches (LxWxH):900 mm X 1500 mm X 900 mm,Type of Frame for installation of bench:C type frame,C Type Fixed Under Bench Cabinet size:500 mm x 500 mm x 540 mm (having one door, one drawer and one adjustable/removable shelf) 54 Supplying ofPowder coated Round Classroom Stools Load of 50 Kg of stool of specification:Height Adjustment: Without Hydraulic,Frame and support made of CHROME PLATED MS TUBES,Chair Type:Non Revolving,Type of seating:Only seat,Pedestal base :Aluminium Die Cast 55 Suppling of Over Head Storage delite hi-tech of specification Material of Construction:ISI Marked, three layer Prelaminated particle Board conforming to Grade II Type III of IS 12823/2013 laminated with 0.6-0.8 mm thick lamination conforming to IS 2046/1995 and balancing lamination of 0.5 mm thick on the back side,Number of Shelves (Nos):2 Number of Doors (Nos) -2 ,Height in mm (±10 mm)-750,Depth in mm (±5 mm)-450 56 Suppling ofStainless Steel Name Plates, Monograms, Labels, As per BHEL ,Specifications :Stainless Steel Name Plates, Monograms, Labels, 57 Suppling of Aquaguard RO & UV both SS304 Drinking Water Coolers With Built In Water Purifiction System AquaguardR 58 Suppling ofStainless Steel External Branding Signage Boards, Size 22X6 Feet,Signage Printing-Single size vinyl print ,Material -Stainless steel ,Coating: Gloss or matte,Fabrication Specs-framing with one coat of red oxide & 2 coats of oil paint to avoid rusting 59 PROVIDING & SUPPLYING DIRECTOR DESKDIRECTOR TABLE STRUCTURE OF L SHAPED DESK .PRIMARY WORK SURFACE OVER ALL SIZE IS 2100MM(L)X 900MM(D)X 750MM(H) 50MM THICK TABLE TOP MADE OF PRELAMINATED PARTICLE BOARD WORK SURFACE WITH CLASSIC WENGE BROWN FINISH 2MM THICK PVC EDGE BANDING MADE OF SAME MATTE FINISH. SIDE PANNEL IS MADE OF 50MM THICK* PROVISION OF SIDE RUNNER OF SIZE IS 1200MM(L)X 400MM(D)X 760MM(H) ,(CCOMBINATION ONSTRUCTION BELOW TABLE TOP 1 KEY BOARD TRAY IN PVC WITH TELESCOPIC CHANNEL ON RIGHT SIDE IS MOVABLESIDE RUNNERHAVING 1 OPENABLE DOOR WITH 1 FIXED SHELVE, 1 OPEN BOX WITH 1 FIXED SHELVE UPPER SHELVE HEIGHT IS @ 320MM BELOW SHELVE HEIGHT IS @324@ + 3 DRAWERS (2 EQUAL DRAWERS + 1 FILLING DRAWER)PER DRAWER HEIGHT IS @ 184MM, FILLING DRAWER HEIGHT IS @ 303MM HAVE CENTRAL LOCKAND HANDLES WITH CASTORS .* MOBILE PEDESTAL OF SIZE400MM(L)X 530MM(D)X 671MM(H) ,PER DRAWER HEIGHT IS @ 186MM, FILLING DRAWER HEIGHT IS @ 195MM HAVING (2 EQUAL DRAWERS + 1 FILLING DRAWER) IN PROVIDED WITH CETNRAL LOCK FOR SECURITY AND HANDLES ARE PROVIDED FOR EASY OF OPENING.OVERALL CONSTRUCTION OF PEDESTAL IS 18 MM ALONG WITH FECIA OF DRAWERS. * THREE LAYER PRELAMINATED PARTICLES BOARD(WOOD PRODUCT) OF GRADE II TYPE III OF IS 12823/LATEST , 60 PROVIDING & SUPPLYING* FIX CANTILEVER CHAIR * ALL OVER SIZE IS : 610MM(L)X 505MM(D)X990MM(H) , *THE CHAIR MADE OF FULL LEATHERETTE IN BLACK COLOUR . IT WILL COMES IN MATTE BLACK FINISH FINSIH IN CONTEMPORARY STYLE .DETAILS :* ARMS :CHROMEFINISH ARMS WITH PU PADDING .* USE OF PLY: 12 MM THICK HOT PRESSED BWR PLYWOOD(IS GRADE - 303 FOR SEAT AND BACK) . * SEAT: 40 ± 2 MM THICK POLYURETHANE FOAM WITH DENSITY 32 (±3) KG PER CU METER FOR BEST QUALITY CUSHIONING IN SEAT , * BACK : 40 ± 2 MM THICK POLYURETHANE FOAM WITH DENSITY 32 (±3) KG PER CU METER FOR BEST QUALITY CUSHIONING IN BACK . BACKREST SUPPORT FOAM DESIGN BASED ON SYMMETRICAL LUMBAR SUPPORTbackrest support* ONLY SEAT SIZE IS 610MM(L)X 505MM(D)X485MM(H) & THE BACK SIZE IS 610MM(L)X 540MM(H) ,* BASE : CHROME FINISH TUBLAR FRAME OF CANTILEVER TYPE . 61 PROVIDING & SUPPLYING OFFICE DESK STRUCTURE OF RECTANGULAR SHAPE .PRIMARY WORK SURFACE OVER ALL SIZE IS 1200MM(L)X 600MM(D)X 750MM(H) 25MM THICK TABLE TOP MADE OF 25MM THICK PRELAMINATED PARTICLE BOARD WORK SURFACE WITH THE EXPOSED EDGES SHALL BE FINISHED WITH 2MM THICK EDGE BINDING TAPE OF MATCHING COLOUR AND SHADE WITH THE HOT MELT GLUE . MODESTY PANNEL MADE OF 18MM THICK, WIRE MANAGEMENT HOLE WITH PVC GROOMENT ON TABLE TOP.*CONSTRUCTION RIGHT SIDE OF TABLE TOP IS BASED ON A FIXED PEDESTAL3 DRAWERS & FROM LEFT SIDE OF TABLE TOP IS BASED ON 18MM THK ENGINEERED WOOD PVC EDGE BANDING PEDESTAL BACK,TOP,BOTTOM & DRAWERS ARE MADE OF 18MM THICK WITH 1 CPU TROLLY MADE IN BLACK METAL POWDER COATED.*FIXED PEDESTAL:L:410MM(L)X 580MM(D)X 750MM(H) ,IN PROVIDED WITH CETNRAL LOCK FOR SECURITY AND HANDLES ARE PROVIDED FOR EASY OF OPENING. OVERALL CONSTRUCTION OF PEDESTAL IS 18 MM ALONG WITH FECIA OF DRAWERS. *THREE LAYER PRELAMINATED PARTICLES BOARD(WOOD PRODUCT) OF GRADE II TYPE III OF IS 12823. 62 Suppling of Material & Subtype Solid Wood - Beech Wood Table Top Material Solid Wood,Leg Material Solid Wood Finish Glossy Colour & Colour Family Brown - Walnut Dimension (W)680mm X (D)530mm X (H)450mm Table Top Thickness 8mm,Size Compact, 63 PROVIDING & SUPPLYING ANGLE RACKOF SIZE 838MM(L)X 305MM(D)X 1676MM(H) STEEL BOOKCASE HAVING 4 DOORS AND K. TYPE OF LOCK: THREE WAYBOLTING DEVICE CONTROLLED BY LOCK, THICKNESS OF MS SHEET USED FOR SHUTTER: 0.7 MM, THICKNESS OF MS SHEET USED FOR SHELF: 0.7 MM, THICKNESS OF MS SHEET USED FOR TOP,BOTTOM, BACK AND SIDES: 0.7 MM, MATERIAL OF HANDLE: CAST BRASS, THICKNESS OF TRANSPARENT GLASS IN SHUTTERS: 4.0 MM, THE COMPLETE STEEL STRUCTURE SHALL BE CONSTRUCTED BY WELDING AND PROVIDE FINISHING WITH EPOXY POLYESTER POWDER COATED TO THE THICKNESS 60-80 MICRONIN COLOR GREY-LIGHT GREY. 64 Suppling of 3 Seater Public Place Seating Chair of mildsteel with arm and backrest WITHOUT CUSHION DURIAN,THREE SEATERTYPE WAITING AREA CHAIR -NIXON/SS/3 MATERIAL : STAINLESS STEEL,SIZE 1820MM(L)X 690MM(D)X 790MM(H)COLOUR : SILVER/WEIGTH OF PRODUCT : 34 KG APPROX,* SUPPLYING AND PLACING IN POSITION OF A STAINLESS STEEL VISITOR BENCH OF SIZE IS 1820MM(L)X 690MM(D)X 790MM(H). THE COMPLETE STAINLESS STEEL BENCH HAS SEAT & BACK SINGLE SECTION. PER SEAT LENGTH IS @ 520 MM &SEATING HEIGHT IS @ 430 MM FROM GROUND . OWING TO THE SMOOTH FINISH, DURABILITY AND TENSILE STRENGTH BEAM STAINLESS STEEL MADE BY 1.6MM THICK.SEAT IS MADE BY 1.2MM THICK STAINLESS STEEL BORDER WITH CHROME PLATING FOR EVERY SEAT & BACK ; STAINLESS STEEL HANDLES CHROME PLATED & DIE PRESSED LEGS AT THE END OF CHAIRS.GROSS WEIGHT OF REGULAR 3-SEATER WILL BE 34 KG.THE STEEL GRADE 202 HIGH YIELD STRENGTH AS PER IS:513 & IS:304 GRADE. 65 PROVIDING & SUPPLYING ANGLE RACKOF SIZE 900MM(L)X 450MM(D)X 1800MM(H) SLOTTED ANGLE RACK (OPEN TYPE) 6 SHELVES INCLUDING TOP & BOTTOM,ANGLES : 40MM X 40MM X 2MM(THICK).,SHELF : 36X15X1MM CRCA SHEET.IN COLOR GREY. 66 PROVIDING & SUPPLYING * FIX CANTILEVER CHAIR PROVIDING & SUPPLYING* ALL OVER SIZE IS : 590MM(L)X 490MM(D)X940MM(H) ,*THE CHAIR MADE OF FULL LEATHERETTE IN BLACK COLOUR .IT WILL COMES IN MATTE FINSIH IN CONTEMPORARY STYLE .DETAILS :* ARMS : PADDED ARMREST.* USE OF PLY: SEAT & BACK PLYWOOD MADE OF 12 MM HOT PRESSED.* SEAT: 40 ± 2 MM THICK POLYURETHANE FOAM WITH DENSITY 32 (±3) KG PER CU METER FOR BEST QUALITY CUSHIONING IN SEAT , * BACK : 35 ± 2 MM THICK POLYURETHANE FOAM WITH DENSITY 32 (±3) KG PER CU METER FOR BEST QUALITY CUSHIONING IN BACK . BACKREST SUPPORT FOAM DESIGN BASED ON SYMMETRICAL LUMBAR SUPPORT* ONLY SEAT SIZE IS 590MM(L)X 490MM(D)X450MM(H) SEAT HEIGHT IS @ 450MM .* BASE : 2 CHROME LEGS + BACK SIDE BOTTOM CHROME IN METAL . 67 * SUPPLYING AND PLACING THREE SEATER EXCLUSIVE PREMIUM LEATHERETTE MODERNIST CLASSIC DESIGN LOUNGE SEATING SOFA SIZE IS 1650MM(L) X750MM(D)X 710MM(H) WITH KILN-DRIED WOOD FRAMING MAKES IT WARP AND SCRATCH RESISTANT,COMFORTABLE SEAT DEPTH & HEIGHT DESIGNED KEEPING MODERN INDIAN LIFESTYLE IN MIND,WRAPPED IN BUTTERY-SOFT PREMIUM LEATHERETTE, THE PANELLED BACK AND CUSHIONED ARMRESTS ENCOURAGE LOUNGING,DESIGNED WITH MODERNITY & ELEGANCE, CHOOSE THE OPTION THAT SUITS YOUR HOME.* COMBINATION CONSTRUCTION STRUCTURE ARE MADE INMOISTURE CONTENT SHALL BE LESS THAN (10-12)%. THICKNESS OF PLYWOOD USED (MM) SHALL BE 12 MM GRADE IS 303 INDIAN STANDARD FOR COMMERCIAL (COMMON) AND MOISTURE PROOF PLYWOOD (TENTATIVE).UNDERSTRUCTURE FRAME SHALL BE CONSTRUCTED FROM 18 MM THICK KILN-DRIED GERMAN BEECH WOOD FRAMING IS HIGHLY DURABLE. THE COMPLETE STRUCTURE SHALL BE COVERED BY P.U.FOAM FIXED WITH ADHESIVE GLUE ,THE FRAME SHALL BE PADDED WITH HIGH RESILIENCE POLYURETHANE FOAM HAVING 25 +/- 5 DENSITY IN SEAT IT SHALL BE STACK FOAM OF 40MM THIK,40MM THICK BACK FOAM HAVING 25 +/- 5 DENSITY FOAM USED ,THERE SHALL BE CUSHION ARM 40MM THICK PROVIDED PADDED WITH HIGH RESILIENCE POLYURETHANE FOAM HAVING DENSITY 25 +/- 5. THE COMPLETE STACK FOAM STRUCTURE SHALL BE COVERED WITH PREMIUM LEATHERETTE IN BROWN-CAMEL BROWN COLOUR, IT COMPLEMENTS THE MODISH SLEEK STEEL . ( SEAT : 545 MM(D) X 410MM(H) , ARMS HEIGHT @ 610 MM /BACK HEIGHT @ 290 MM). 68 SUPPLYING AND PLACING30 SEATER U - shape MEETING TABLE with table top of Three Layer Prelaminated ParticleBoards Of Grade-II Type-II Of IS:12823/Latest (for 14 seater rate devided by 30X24} 69 SUPPLYING AND PLACING PREMIUM SUITESDIRECTOR TABLE STRUCTURE OF L-SHAPED DESK .PRIMARY WORK SURFACE OVER ALL SIZE IS 2400MM(L)X 2330MM(D)X 770MM(H) 45MM THICK TABLE TOP MADE OFSUPPLYING AND PLACING PRELAMINATED PARTICLE BOARD WORK SURFACE WITH RICH CHERRY FINISH SAME MATCHING EDGE BANDING MADE OF SAME RED CHERRY P.U POLISH.MODESTY IS DESIGNED WITH LEATHER PATCH.SIDE PANNEL IS MADE OF 36MM THICK .* PROVISION OF SIDE UNIT OF SIZE IS 1200MM(L)X 595MM(D)X 770MM(H) ,(COMBINATION CONSTRUCTION ON TABLE TOP WIRE MANAGEMENT 2 HOLE WITH SS GROOMENT & 1 HOLE WITH PVC GROOMENT ON TOP SIDE UNIT. BELOW TABLE TOP ONE KEYBOARD TRAY,IN SIDE UNIT BELOW THE TOP 1 KEY BOARD TRAY,1 OPEN BOX FILE ,1 DRAWER + 1 OPEANABLE DOOR SHELVE. * FIXED PEDESTAL OF SIZE450MM(L)X 400MM(D)X 690MM(H) , HAVING 3 EQUAL DRAWERS IN PROVIDED WITH CETNRAL LOCK FOR SECURITY AND HANDLES ARE PROVIDED FOR EASY OF OPENING. OVERALL CONSTRUCTION OF PEDESTAL IS 18 MM ALONG WITH FECIA OF DRAWERS. * ALL THE MDF BORAD ARE IS-14587-1998 WITH CONFIRM TO DIN 68861.ISO 9001- 2015 QUALITY CERTIFICATION CONFIRMING TO ASTM D 4499 STANDARDS FOR VISCOSITY AND THERMAL STABILITY . 70 SUPPLYING AND PLACING* HIGH BACK 360° DEGRE REVOLVINGCHAIR * ALL OVER SIZE IS : 673MM(L)X 508MM(D)X1270MM(H) , *THE CHAIR MADE OF FULL NATURAL LEATHER IN BROWN COLOUR . IT WILL COMES IN MATTE FINSIH EXTRA PADDED DESIGNED FOR MORE CONFIRMT AT WORKPLACE IN CONTEMPORARY STYLE . DETAILS :* ARMS : WOODEN ARMS WITH LETHER PADDING ARM REST ARE FITTED TO THE SEAT & BACK.* USE OF PLY: 12 MM THICK HOT PRESSED BWR PLYWOOD(IS GRADE - 303 FOR SEAT AND BACK) .* SEAT: 40 ± 2 MM THICK POLYURETHANE FOAM WITH DENSITY 32 (±3) KG PER CU METER FOR BEST QUALITY CUSHIONING IN SEAT . * BACK : 40 ± 2 MM THICK POLYURETHANE FOAM WITH DENSITY 32 (±3) KG PER CU METER FOR BEST QUALITY CUSHIONING IN BACK .BACKREST SUPPORT FOAM DESIGN BASED ON SYMMETRICAL LUMBAR SUPPORT* MECHANISM : MULTI-LOCKING KNEE TILT MECHANISM .SEAT MAXIMUM HEIGHT IS 580MM & MINIMUM HEIGHT IS 500MM & BACK HEIGHT FROM FLOOR MAXIMUM HEIGHT IS 1270MM & MINIMUM HEIGHT IS 1219MM* GAS LIFT 80MM TELESCOPIC HAUDRAULIC * BASE : THE PRONG (BASE) IS MADE OF SOILD WOOD WITH POLISHEDAND FITTED WITH 5 NUMBERS. TWIN WHEEL CASTORS (CASTOR WHEEL DIA. 50MM) & 700MM PITCH CENTER DIA (740MM WITH CASTORS) . 71 SUPPLYING AND PLACING Material & Subtype Leather - Semi Aniline Leather,Metal - Stainless Steel,Frame Material Solid Wood Upholstery Material Leather,Seat Material Leather Leg Material Metal,Finish Matte,Colour & Colour Family Beige - Mushroom,Dimension (W)1140mm X (D)1000mm X (H)940mm Mechanism Click Clack Mechanism,Seating Capacity 1 Seater Seating Height 430mm,Function Adjustable Headrest Size Grand. 72 SUPPLYING AND PLACING Material & Subtype Leather - Semi Aniline Leather,Metal - Stainless Steel,Frame Material Solid Wood,Upholstery Material Leather,Seat Material Leather,Leg Material Metal,Finish Matte,Colour & Colour Family Beige - Mushroom,Dimension (W)2130mm X (D)1000mm X (H)940mm Mechanism Click Clack Mechanism,Seating Capacity 3 Seater Seating Height 430mm,Function Adjustable Headrest Size Grand. 73 SUPPLYING AND PLACING Rectangular CENTRE TABLE with Marble Top of 1219mmX711mm,(DAISY/CT (W)1300mm X (D)650mm X (H)450mm),Specifications:Number of storage under top No storage,Top material,Tempered glass,Frame material No frames,Dimension of Top (Length X Breadth, or Diameter) ±20mm,762mmX457mm,Height of centre table ±10mm,410,millimeter,Thickness of top material (+/-2 mm)- 8 millimeterThickness of frame material (+/- 1 mm)-10 millimeter 74 SUPPLYING AND PLACING 14 SEATER oval MEETING TABLE with table top of Three Layer Prelaminated Particle Boards Of Grade-II 75 SUPPLYING AND PLACING 6 Seater Sofa Material & Subtype-Premium Leatherette,Frame Material Solid Wood,Upholstery Material Premium Leatherette,Filling Material Foam,Silicone Fiber,Seat Material Premium Leatherette-Leg Material Solid Wood,Finish Matte,Colour & Colour Family Brown -Coffee Brown Dimension (W)4865mm X (D)960mm X (H)820mm,Seating -Capacity 3 Seater,seating Height 475mm,Size Standard 76 SUPPLYING AND PLACING9 SEATER U -* PROVIDING & SUPPLYING U - SHAPE MODERN DESIGN CONFERENCE TABLE & IN BETWEEN U SHAPE TABLE TOP LENGTH IS @ 4650 MM, TABLETOP OFFERS YOU A GENEROUS WORKSPACE,DESK PRIMARY WORK SURFACE USE PREMIUM QUALITY MATERIALS OVER ALL SIZE IS 4650 MM(L)X 600MM(D)X 750MM(H) TABLE TOP MADE OF 36MM THICK WHICH GIVE MORE SURFACE AREA FOR WORK ,MACHINE MADE MODULAR FURNITURE MADE PRELAMINATED PARTICLE BOARD OF GRADE II TYPE III OF IS 12823/LATEST,* CONSTRUCTION PROVISION OF CONFERENCE TABLETOP SUPPORTED WITH 18MM THICK SIDE PANNELS IN BROWN-BLACK OAK COLOUR MADE BY PRELAMINATED PARTICLE BOARD AND BELOW THE TOP 18MM THICK PRELAM PARTICLE BOARD MODESTY PANEL.OUR WORK SURFACE FURNITURE IS FINISHED WITH EXPOSED EDGES SHALL BE FINISHED WITH 2MM THICK EDGE BINDING TAPE OF MATCHING COLOUR AND SHADE,FIXED WITH HOT MELT GLUE. * THREE LAYER PRELAMINATED PARTICLES BOARD(WOOD PRODUCT) OF GRADE II TYPE III OF IS 12823/LATESt. 77 * SUPPLYING AND PLACING THREE SEATER EXCLUSIVE PREMIUM LEATHERETTE MODERNIST CLASSIC DESIGN LOUNGE SEATING SOFA SIZE IS 1650MM(L) X750MM(D)X 710MM(H) WITH KILN-DRIED WOOD FRAMING MAKES IT WARP AND SCRATCH RESISTANT,COMFORTABLE SEAT DEPTH & HEIGHT DESIGNED KEEPING MODERN INDIAN LIFESTYLE IN MIND,WRAPPED IN BUTTERY-SOFT PREMIUM LEATHERETTE, THE PANELLED BACK AND CUSHIONED ARMRESTS ENCOURAGE LOUNGING,DESIGNED WITH MODERNITY & ELEGANCE, CHOOSE THE OPTION THAT SUITS YOUR HOME.* COMBINATION CONSTRUCTION STRUCTURE ARE MADE INMOISTURE CONTENT SHALL BE LESS THAN (10-12)%. THICKNESS OF PLYWOOD USED (MM) SHALL BE 12 MM GRADE IS 303 INDIAN STANDARD FOR COMMERCIAL (COMMON) AND MOISTURE PROOF PLYWOOD (TENTATIVE).UNDERSTRUCTURE FRAME SHALL BE CONSTRUCTED FROM 18 MM THICK KILN-DRIED GERMAN BEECH WOOD FRAMING IS HIGHLY DURABLE. THE COMPLETE STRUCTURE SHALL BE COVERED BY P.U.FOAM FIXED WITH ADHESIVE GLUE ,THE FRAME SHALL BE PADDED WITH HIGH RESILIENCE POLYURETHANE FOAM HAVING 25 +/- 5 DENSITY IN SEAT IT SHALL BE STACK FOAM OF 40MM THIK,40MM THICK BACK FOAM HAVING 25 +/- 5 DENSITY FOAM USED ,THERE SHALL BE CUSHION ARM 40MM THICK PROVIDED PADDED WITH HIGH RESILIENCE POLYURETHANE FOAM HAVING DENSITY 25 +/- 5. THE COMPLETE STACK FOAM STRUCTURE SHALL BE COVERED WITH PREMIUM LEATHERETTE IN BROWN-CAMEL BROWN COLOUR, IT COMPLEMENTS THE MODISH SLEEK STEEL . ( SEAT : 545 MM(D) X 410MM(H) , ARMS HEIGHT @ 610 MM /BACK HEIGHT @ 290 MM) 78 SUPPLYING AND PLACING Wooden Acoustic Wall Cladding/Panelling- Providing and fixing in position wood wall paneling of width 128mm, thickness of 16mm and length 2440 mm made up of high density fiber board with minimum density of 800 Kg/m3 substrate with a laminated facing/wood veneer as per the approved shade/species & finish with melamine balancing layer on the reverse side. The boards shall have a special perforation pattern of 2mm groove & 14mm pitch. The panels shall have fire resistance of Class 1, BS 476 part 7. The edges of the panels shall be tongued-and-grooved to receive special clips for installation. The back of the perforated panel shall have sound absorbing non-woven acoustical fleece and backed with 50mm thick glass wool layer as directed by the Engineer-in-Charge. The panel shall be mounted on special channels using clips as approved by the Engineer -in-charge. Install Gel stud of section 48X34X36 mm or as approved by the Engineer -in- Charge on the solid wall horizontalty using screws and plugs at spacing of 600mm centre-to-centre, Screw the aluminium channel (keel) vertically on channeled G.I stud 600mm 79 SUPPLYING AND PLACINGBlackout roller blind,Specifications-Mounting arrangement profile systems – clicked on hidden mounting clipsTypes of roller blind,Blackout roller blind-Shading solutionSingle roller blind – utilise one layer of fabric (called outer layer Operating mechanism-Side winders (that lock the manually adjustable blinds at different levels with the internal ratchet and tension adjusted by spring inside the tube) 80 Providing and Fixingof Drawers in Brown Finish ,Specification-Material : High QualityParticle board Dimensions (In Centimeters)-H 91 x W 90 x D 44 Dimensions (in Inches)-H 36 x W 35.5 x D 17.5 Primary Material-Engineered Wood as per Engineer incharge 81 Providing and FixingSTAGE - Providing & fixing raised stepped floor (Stage) Consisting ofMS Tabular frame work ofPipe Section (HOT ROLLED/COLD ROLLED) size 50mmx 50mmx2.0mm.tk. duly Painted with one coat of Red Oxide steel Primer, fabricated in module of 600 x 600 mm frame gid (as per Design or as instructed) with support of same section Legs /frame fixed on existing floor from base and raised at height minimum 150mm to max 200mm as required, from Existing floor. Vc providing and fixing 18mm thick heavy duty high density (1450 kg/cum) cement fiber Board fixed by SS. Screw on Horizontal & Vertical Surface on Existing Framework with one coated cement primer on Board and covering Board from top and sides by 2mm thick Vinyl flooring of approved make,colour and texture to be layed and fixed on sub floor smoothly finished and levelled by recommended adhesive cutting fixing and including covered raised portion of Board from all sides etc. complete,suitable for use up to the satisfaction of Engineer- in-charge.Design as approved by Engineer-In-charge. Base ofthe Vertical Legs of M.S. Frame (COLD ROLLED/HOT ROLLED) 82 Providing, fixing & installation MICROPHONE:-Flat frequency response across the vocal range for uncolored sound interchangeable cardioid, supercardioid, and omnidirec- tional cartridges that provide choices for applications Sleek, low-profile design for unobtrusive appearance Balanced transformerless output for increased immunity to noise over long cable runs-Compact Cinema Surround Speaker for Digital Applications:- Frequency range: 50 Hz to 20 kHz • High sensitivity: 91 dB SPL, IW @ 1m (3.3 ft) High power handling capability: 150 watts, continuous pink noise Internal Thermomaster• technology allows for unprecedented high frequency power in a compact, molded enclosure Convenient mounting design supports JBL QuickMountre, OmniMount• or APC multimount brackets Special cabinet shape incorporates 20• angled front baffle SMPTE/lS02969 Curve X high frequency de-emphasisMixer 8 input mono mixer XLR input switchable between mic and line level +/- 15dB gain trim control per input Input 1 is switchable to be pre/post master 24VDC or mains power operation Optional remote VCA/Tone generator/ Muting boards available • Whisper quiet operation 83 Supply, Installation, Testing and commissioning of microphone Delegate unit. 84 Supply, Installation, Testing and commissioning of microphone Chaiman unit, 85 Supply , Installation , testing and commissioning of Factory made 1.4HDMl Cable along with connector (15mtr length) 86 Supply , Installation , testing and commissioning of Factory made VGA along with Connectors.(15mtr length) 87 Supply , Installation , testing and commissioning of Factory made RCA along with Connectors.(15mtr length) 88 Supply , Installation , testing and commissioning 40W power Amplifier of following features:- Rated output wattage - 240W, amplifier output IOOV, 70V and 4-16 ohms transformer isolated speaker outputs, Supply input 0.775 v (OdB) unbalanced, 10k ohms, XLR and phone jack frequency 89 Supply , Installation , testing and commissioning10W wall mount speaker- Supplying, installation, testing and commissioning of 240W power amplifier with following features:- Rated output wattage- 240W, amplifier output 100V, 70V and 4-16 ohms transformer isolated speaker output, Supply input 0.775 v (0 db) unbalanced, 10k ohms, ZLR and phone jack frequency response 50 - 18000 Hz, +/- 1.5 dB, S/N ratio > 105 dB. 90 Supply , Installation , testing and commissioningCONFERENCE CONTROL UNIT, line Output 1 17.5V DC/3a Max.; -34dBV (20mV), line Output 2 17.5V DC/3a Max.; -34dBV (20mV), power Output 50w rMS at 2% THD, 90w Max. inputs 3xMic 0.65mV/4.7kQ Ixaux IOOmV/470kQ Frequency response 60-14,000Hz (± 3dB) 91 Supplying of Material & Subtype Engineered Wood Finish Matte,Colour & Colour Family Brown - Wenge Dimension (W)800mm X (D)384mm X (H)1970mm Size Standard,Style Contemporary,Assembly Type Knock Down 92 Supplying of Powder Coated Extruded Aluminium Sections Hybrid panel based system (combination of sliding & snap fit tiles) Modular Work Stations 93 Supplying of11 SEATER U - shape MEETING TABLE with table top of Three Layer Prelaminated Particle Boards Of Grade-II Type-II Of IS:12823 94 SUPPLYING AND PLACINGSLOTED ANGLE RACKOF SIZE 900MM(L)X 450MM(D)X 1800MM(H) SLOTTED ANGLE RACK (OPEN TYPE)6 SHELVES INCLUDING TOP & BOTTOM,ANGLES : 40MM X 40MM X 2MM(THICK).,SHELF : 36X15X1MM CRCA SHEET.IN COLOR GREY, 95 SUPPLYING AND PLACING : METAL STORAGE OF SIZE 900MM(L)X 450MM(D)X 1980MM(H) BODY MADE OUT IN 22 GAGUE(0.8MM) & DOOR 19 GAGUE(1 MM) CRCA SHEET. 4 ADJUSTABLE SHELVE IN 22 GAGUE(0.8MM) & PEDESTAL 18 GAGUE 1.2 MM CRCA SHEET. HAVING FOUR SHELVES MAKING FIVE COMPARTMENT, UNIFORMLY DISTRIBUTED LOAD CAPACITY OF EACH SHELF SHALL BE 60 KG MAXIMUM,FITTED WITH MS BODY LOCK & HANDLE. FINISHING WITH EPOXY POLYESTER POWDER COATED TO THE THICKNESS 50-60 MICRONS(+/-5 MICRON)IN COLOR GREY-LIGHT GREY. 96 Providing and fixing e Slimline Tower AC (2 Ton White),Availability of BIS/ISI Mark Certification for Split AC Floor type-Yes,Technology of air conditioner,Non Inverter AC-Nominal Marketing capacity as per BEE Star Rating Label (hint: 1 Ton = 3000 Kcal/Hr, Tolerance +/- 10%) (in Ton)-3 BEE Star rating of the product (Central Ministries/Departments while procuring shall ensure that the items carry 5 star (under normal conditions where annual usages is expected to be more than 1000 hrs),3 Star (where usage is Limited)or higher Star R NA- Star rating for the capacity of >10,465 Watts (>9,000 kcal/hour) 97 Providing & Fixing 2.0 mm thick homogenous single layered vinyl flooring. The flooring shall be laid in manner to provide comfortable and jerk free surfaces including material, adhesive, scaffloding and lead and lift at all floor level etc. complete as per direction and approval of Engineer-in-charge. 98 Providing & Fixing Wiring for Primary Raw Power point 2 sets of 6 Amp Switch-Socket Outlet with 2.5 sq.mm FR PVC insuate copperconductor wire in surface / recessed 25mm medium class PVC conduit, earthing the third point With 2.5 sq.mm FR PVC insulated copper conductor Wire. Including Providing and fixing 2 nos 6A Switch with Front plate and metal Box with all Accessroies for users. 99 Providing & Fixing Wiring for Secondry Raw Power point 2 sets of 6 Amp Switch-Socket Outlet with 2.5 sq.mm FR PVC insulated copper conductor wire in surface / recessed 25mm medium class PVC conduit, earthing the third point with 2.5 sq.mm FR PVC insulated copper conductor Wire. Including Providing and fixing 2 nos 6A Socket controlled by 1 nos 6A Switch with Front plate and metal Box with all Accessories. 100 Providing & Fixing Wiring for Primary Raw Power point 1 sets of 6 Amp Switch-Socket Outlet with 2.5 sq.mm FR PVC insulated copper conductor wire in surface / recessed 25mm medium class PVC conduit, earthing the third point with 2.5 sq.mm FR PVC insulated copper conductor Wire. Including Providing and fixing 1 nos 6A Socket controlled by 1 nos 6A Switch with Front plate and metal Box with allAccessories. 101 Providing & Fixing Wiring for Secondry Raw Power point 1 sets of 6 Amp Switch-Socket Outlet with 2.5 sq.mm FR PVC insulated copper conductor wire in surface / recessed 25mm medium class PVC conduit, earthing the third point with 2.5 sq.mm FR PVC insulated copper conductor Wire. Including Providing and fixing 1 nos 6A Socket controlled by 1 nos 6A Switch with Front plate and metal Box with allAccessories. 102 Wiring for Primary Power point 6/16 Amp Switch-Socket Outlet with 4 sq.mm FR PVC insulated copper conductor wire in surface / recessed 25mm medium class PVC conduit, earthing the third point with 2.5 sq-mm FR PVC insulated copper conductor Wire. Providing and fixing 1 nos 6/16A Socket controlled by 1 nos 16A switch with front plate and metal box with allAccessories. 103 Providing & Fixing Standing Bathtubs Specifications:Size:1690x800x445/565mm Free Standing Bath Tub with Over Flow & Drain 104 Providing & Fixing Corazzin Garden Patio Seating Chair and Table Set Outdoor Balcony Garden Coffee Table Set Furniture with 1 Table and 4 Chairs Set (Black) 105 Providing & Fixing Reliable Drapes Cotton Plain Door Curtains Reliable Drapes,Cotton GSM Quality-220,Lining included-No, Pack of-1,Length (Ft)-8.5-9,Width (Ft)-3-3.5 106 Providing MattressDimension 1981 mm X 1829 mm,Thickness of Core Layer (Height of Spring) 200 mm,Thickness of Felt (±1 mm) for Bonnell Spring 12 mm,Thickness of Top Layer (±2 mm)-50 mm Thickness of Bottom Layer (±2 mm)50 mm,Type of Spring in Core Layer Bonnell Spring (with cotton felt),Material of Top Layer Visco Elastic PU Foam (Memory Foam) 107 ProvidingCotton Pillow 33 cm x 56 cm (COTTON PILLOW)of Specification-BIS Marking ( For Body Casing fabric )-No Logo Marking-No,type of Logo,Stitched ( Patch Logo ),Agree to provide 108 Providing240 centimeter x C1112M 135 centimeter (L x W) Printed Bed Sheets(BED SHEET ):Technical Specification of the Product-Sheeting, Tickings and Bedsheets (V2) as per IS 175 BIS Certifcation-No,VarietyVariety - 2,Process of colouring Dyed,Matching Pillow cover 109 Providing 25 liter 3 Star Water Heater,25 Ltr 5 Star Water HeaterCapacity litres (Litres),BEE Star Rating (Central Ministries/ Departments while procuring shall ensure that the items carry 5 star or higher Star Rating of BEE)-3,Availability of Type Test Report from Central Govt/NABL/ILAC accredited lab to prove conformity to specification-No,Material of Inner Container Vitreous enamelled inner tank conforming to IS-13273 110 Providing Wall Mount Mesh Filter T-Shapped Kitchen-Chimney Material of Blower Body-Aluminium,Material of Blower Blade Aluminium,Material of Exhaust pipe-pvc,Filter Material,Stainless Steel,ShapeT-Shapped,Filter Type,Mesh Filter,Control Panel Type Soft Touch,Mount Type,Wall Mount 111 Providing Potable Water Purification System With Inbuilt Water Cooler. RO UV Aquaguard(Hot & Cold uv+ ro) Specifications-Flow rate (Litres/hr.)-12,Cold water storage capacity (Litres)-11 liter,Cooling capacity (litres/hr.)-4,Hot water storage capacity (Litres)-1.5 liter,Heating capacity (litres/hr.)-1.5,Cooling power consumption (Watts)-230,Heating power consumption (Watts)-550. 112 Providing300 L 3 Star Frost Free Double Door Refrigerator, of specification Cooling type:Frost free,Exterior body built:steel,Shelf material -Toughened glass,Voltage Range-160-300V,frequency-50 Hz 113 Providing900 mm wide 2000 mm high Metal Shelving Racks,Specifications :Type-OPEN TYPE Number of Shelves/Compartments (Top / Ceiling Shelf - not to be counted)-4,Shelves Material-0.8 mm Thick MS Sheet Conforming to Commercial Quality CR-1, Grade 340 of IS 513,Depth in mm (±5 mm)-400,Width in mm (±5 mm)-900,Height in mm (±5 mm) 2000 114 Providing and fixing Drawers of Specification of Dimension (in cm)-H91 X W90 X D44in Brown Finish,primary material-Engineered wood,Weight 49.45kg 115 Providing and fixingDressing Table With cupboard and open shelves-Design of Dressing table With drawers,cupboard and open shelvesBase of dressing table Rectangular wooden frame Number of side mirror-1 number, Material specification-Prelaminated particle board of grade II type III of IS 12823/Latest.both side laminated. outer side laminated with shade matching with top shade and fascia shade and having balancing laminate of 0.5mm thick on other side Material thickness of complete body, Fascia and drawer/cupboard-19 millimeter,Material thickness for back, partition and drawer /cupboard bottom ± 2mm,19 millimeter 116 Providing and fixing Material & Subtype Solid Wood - Rubber Wood Table Top Material Solid Wood-Frame Material Solid Wood,Finish Glossy,Colour & Colour Family Brown - Walnut Dimension Of Table (W) 600mm X (D) 600 X (H) 610mm Dimension Of Chair (W)640mm X (D)530mm X (H)560mm Size Standard 117 Providing and fixing Wooden Double Bed Storage Box Opening From Material of Mattresses Panel-Other wood, Material of Bottom Panel of Storage Box-Three layer prelaminated particles board (Wood product) of grade II type II of IS 12823/Latest Material of Front, Back and side Panels Three layer prelaminated particles board (Wood product) of grade II type II of IS 12823/Latest Material of Headrest Three layer prelaminated particles board (Wood product) of grade II type II of IS 12823/Latest Material of Legrest-Three layer prelaminated particles board (Wood product) of grade II type II of IS 12823/Latest,Type of Bed-Wooden Double Bed Material of Bed Frame-Three layer prelaminated particles board (Wood product) of grade II type II of IS 12823/Latest 118 Providing and fixing 1 Seater Sofa With Leatherite Cover Sofa Set is Foldable to use as bed-No Backrest Cushion Material-Foam,density of Cushion of Backrest Material (Kg/Cubic M)-40 Covering Material for Seat and Backrest Fabric Frame Structure Material and size (±1 mm) Any other wood of minimum 25 mm thickness Seat Cushion MaterialFoam 119 Providing and fixing 8 SEATER Rectangular MEETING TABLE with table top of Three Layer Prelaminated Particle Boards Of Grade-II Type-II Of IS:12823/(Elanor Marble 8 Seater Dining Set) 120 Providing and fixing MODULAR TABLE L X D & H 2000 millimeter X 450 millimeter 700 millimeter (Alice TV Unit marble),Sprcification-Mode of Supply of modular table Knocked Down to be assembled at consignee site by the Seller Storage Provided one side,Number of storage unit-triple storage,Table Top material and thickness ±3mm-25mm thickness three layer pre-laminated Particle boards (Wood Product) of grade II Type II of IS 12823 Latest Gable end and modesty panel material and thickness-18 mm thickness three layers pre-laminated Particle boards (Wood Product) of grade II Type III of IS 12823 Latest 121 Supplying of Library Management Department. and NDL Softwares,Server Machines, Air-Condition Systems,Xerox Machines,Lamination Machines, CONNECTION)Binding Machines,Furniture/Furnishing. Computers, Printers,Computer System(with Internet Connection) 122 Supplying of Printer of Specification A Printing Technology Laser-Cartridge Technology,Composite Cartridge,Type of Printing Mono,Paper Size-A4 Print Speed per minutes per Department Incharge 123 Supplying of XEROX Machine(standard company) Type of MachineMultifunction Machine,Print Technology-Laser Type of Printing-Mono,Cartridge Technology Separate Drum and Toner (Dual Component) Platen/Flatbed Size-A3/A4,Paper Size (Original/Image)A3/A3 RAM size (MB)-4096as per Department incharge 124 Supplying of Determination of wavelength of He-Ne Laser light using Grating(Specification- Output Power: up to 15mW, CW - Wavelength: 632.8nm,* Mode Structure: TEM00 (>95%)* Beam size: <= 1mm* Beam Divergence: <= 1.5 mrad* Polarisation: Unpolarised, Vertical Polarisation. complete set up as per Department incharge 125 Supplying of Brewsters Law using spectrometer(Brewsters angle apparatus differ goniometer digital research bench polarizer analyser with rail type bench abron). complete set up as per Department incharge 126 Supplying of Determination of wavelength of Sodium light using Michelson interferometer(Power-3 kW,Usage-Physics Lab,Material-Mild Steel,Power Source,Electric Voltage 240 V). complete set upas per Department incharge 127 Supplying of Determination of wavelength of Sodium light using FabryPerot interferometer complete set up of Specification Flatness of Reflective Mirrors-λ/20 Diameter of Reflective Mirrors-30 mm Reflectance of Mirrors-95% Effective Travel of Preset Micrometer~ 3 mm Min Division Value of Preset Micrometer-0.01 mm Travel of Fine Adjustment of Movable Mirror-1.25 mm Resolution of Fine Adjustment-0.0005 mm Low-Pressure Sodium Lamp-20 W as per Department incharge 128 Supplying of Resolving Power of Telescope complete set up (specification Color-BlackMaterial-Plastic as per Department incharge) 129 Supplying of Resolving Power of Prism(Resolving power of telescope assists the user to know the basic principle of telescope. Fabricated using excellent quality metals, glass and plastic material, it is widely used instrument in scientific lab of colleges and research centers. It is known for accurate calculation and longer service life) complete set up as per Department incharge 130 Supplying of Production and analysis of Polarised light using half and quarter wave plate(Usage/Application Laboratory Voltage-230 V,Color-Black,Material-SS). Complete set up as per Department incharge 131 Supplying ofLogarithmic Amplifier(Built in power supply : +15V & -15V DC,Mains : 230V AC,Dimension : 27CMS X 17CMS [metal cabinet,Weight : 2KGS APPX) complete set up as per Department incharge as per Department incharge 132 Supplying of Zener diode characteristics & voltage stabilizer. Complete-Specification:(Voltage-240 V Frequency-60 Hz,Display Type -Analog)in all respect as per Department incharge 133 Supplying of FET characteristics complete up(Technical specifications-Inbuilt variable, overload & short circuit protected DC regulated power supplies of 0- 5 volt & 0- 15 volt.Voltmeter & ammeter are mounted on the front panel.One FET.Highly insulated front panel .Trainer helps to demonstrate the working principle of FET.Set of required number of patch cords.Multi - colored sockets are used.Housed in an elegant powder coated metal cabinet.Strongly supported by a comprehensive instruction manual complete with theory and operating details.LED indication for supply “ON” to work on 220V AC Mains.) as per Department incharge 134 Supplying of MOSFET characteristics complete set up(Specificaion:Power-AC Mains,Usage/Application-Laboratory Type-Analog,Material-plastic,Power Supply-ac mains, as per Department incharge 135 Supplying of UJT characteristics complete set up(Specification-Usage/Application-laboratory,Type-Analog,Display Type-Analog meters,Power Supply-ac mains)as per Department incharge 136 Supplying of Transistor biasing (CE mode)(Specificaion-Operating Power Supply-220VAC On Board Power Supply 0-1VDC & 0-10VDC Experiment Input & Output Char In CB & CE Mode OF PNP Tr.Meter Type Analog / Digital)set up as per Department incharge 137 Supplying of Characteristics of SCR(SpecificationUsage/Application-laboratory Type-Analog Automation Grade-Manual ,Power Supply-ac mainscomplete set up as per Department incharge 138 Supplying of Basic Logicgates and Universal gates. Operating Supply Voltage 230V,Logic Family-DIGITAL,Number of Inputs per Gate-2,Usage Laboratory,Material-ELECTRONIC Complete set up in all respect as per Department incharge 139 Supplying of Op-amp Integrator &Differentiator. Complete set up in all respect :Product Specification:Type-Analog Material-Metal,Automation Grade=-Manual,Color-black with multicolour PVC front panel,Power Supply-230,Capacity--5,connector Type-patch cord sas per Department incharge 140 Supplying of Half Adder, Full Adder and 4-bit binary Adder. Complete set up in all respect (Product Specification:Type-Digital,Display Type-Digital Interface--NO Material-ABS,Display-Digital,Pulse Generator-50Hz Variable Dc Output-no)as per Department incharge 141 Supplying of G. M. Counter for 6 digits GM counter with built in power supply complete set up(G.M.COUNTER: COMPLETE WITH INBUILT POWER SUPPLY EHT 250-1200v Workable on 220v. 50Hz., Power consumption 8W approx. STOP, START, RESET switches. Counts Capacity : 6 DIGIT COUNTING SYSTEM, Preset time : 3 DIGIT PROGRAMABLE TIMER WITH DIGITAL DISPLAY. 3 ½ Inbuilt Digital Volt Meter for GM TUBE Voltage. G.M.TUBE: END WINDOW G.M.TUBE MOUNTED IN ACRYLIC STAND. WITH ‘LEAD’ AND ‘ALUMINIMUM’ ABSORBENTS, Radioactive Source: ONE RADIOACTIVE SOURCE BETA or GAMMA (in Lead Container and wooden Box) SOURCE, . Dimensions : 460X370X230mm.(Complete instrument is HOUSED in corrugate box with Export Packaging) Wight : Total weight of the Instrument is 5.5kg.) as per Department incharge 142 Supplying of Measurement of Dielectric constants of solid and liquid samples complete set up(It Consists of following partsRF Generator (9-10MHz Approx) Micro Ammeter (Range 0-50mA) Potentiometer for Sensitvity Selection Fixed Capacity (Metal) Variable Gang Capacitor Socket for test Capacitor & Variable Capacitor brought out at front panel One Solid bakelite plate to be insert in gap of test capacitors)as per Department incharge 143 Supplying of Study of Dielectric constants and Curie temperature of ferroelectric ceramics Complete in all respect(Specifications Temperature Range : Ambient to 200°C,Display : 31/2 digit, 7 segment LED with autopolarity & decimal indicationResolution : 0.1°C,Accuracy : ±0.5°C (typical),Stability : ±0.1°C Power : 150W,(ii) Digital Capacitance MeterThis a compact direct reading Instrument for the measurement of capacitance of the sample. Specifications,Range : 50-6000 pf,Resolution : 1pf Display : 3½ digit, 7 segment LED, Typical results obtained with the above set-up are as shown in the graph) as per Department incharge 144 Supplying of Determining Optical constants of a metal by reflection of light Complete in all respect (Specification-Power-AC Mains,Usage/Application-Laboratory,Type-Digital Material-Metal,Automation Grade Manual,Color-White Power Supply-AC Mains,Display Type-Digital) as per Department incharge 145 Supplying of Lattice dynamics kit with frequency meter (Technical Specifications: Audio Oscillator 100 khz,Built in Power Supply and Output Stage to match the Impedance of Simulated Lattice,Lattice DynamicKit consists of Transmission line, which Simulates One-Dimensional Mono-AtomicandDi-atomicLattices,. LCD Based Frequency Counter is Provided on panel to Measure Frequencycomplete set up as per Department incharge 146 Supplying of BCD to seven segments complete set up(Specification:Built in power supply : +5V DC Mains : 230V AC Dimension : 27CMS X 17CMS [metal cabinet] Weight : 2KGS APPX) as per Department incharge 147 Supplying of Monostable Multivibrator using Oscilloscope (CRO) complete set up (Specification:Usage/Application Laboratory Packaging Type-Corrugated Box,Connector-2mm sockets Frequency Range -50Hz) as per Department incharge 148 Supplying of Bistable multivibrator using Oscilloscope(CRO))Technical Specification:(Built in power supply : +12V & -12V DC Mains : 230V AC,Dimension : 27CMS X 17CMS [metal cabinet] Weight : 2KGS APPX)complete set up as per Department incharge 149 Supplying of Pulse code modulation and demodulation complete setup (Product Specification,Type Laboratory Trainer Kit Usage/Application-Laboratory,Accuracy-+/- 10%,Frequency-50 Hz Input Voltage-220V,Packaging Type-Corrugated Box,Power Source-ElectricShape-Rectangular,Material-ABS or Metal Cabinet)as per Department incharge 150 Supplying of Addition, Subtraction, Multiplication using 8086 microprocessor(Product Specification,Usage/Application-LaboratoryType-Fully Automatic,Automation Grade-Semi-AutomaticClock Frequency-Yes,Color-Green,Display-Digital Packaging Type-Corrugated Box, Power-200-400 Weight 2 Kg) as per Department incharge 151 Supplying of Thevenin theorem, (THEVENIN’S AND NORTON’S THEOREM APPARATUS,Technical specifications Inbuilt fixed DC regulated power supply of 12 volt. Voltmeter & ammeter are mounted on the front panel. Resistive network is used in the circuit. Circuit diagram is printed on highly insulated front panel . Trainer helps to demonstrate the working principle & verification of Thevenin’s & Norton’s Theorem based on resistive circuit. Student can calculate & measure the value of current & voltage for different load circuits. Calculation of power consumed by the circuit. Facility for connecting external Power Supply. Set of required number of patch cords. Multi - colored test points are provided in the circuit to observe voltages at different points. Housed in an elegant powder coated metal cabinet. Strongly supported by a comprehensive instruction manual complete with theory and operating details. LED indication for supply “ON” to work on 220V AC Mains. Circuit protection through glass fuse)Complete set up as per Department incharge as per Department incharge 152 Supplying of Active filter set up(Product Specification Operating Temperature-0-50,Frequency (Hz) 50,Condition-New Temperature (deg. Celsius)-50,Usage/Application Industrial, Educational, Residential, Commercial) as per Department incharge 153 Supplying of A to D counter type complete set up (Product Description-M-32 AD M-16 AD,Input AD: 1/4 TRS jack and 25 pin D-sub, servo balanced, completely symmetrical audio path, Output AD: 4 x ADAT optical, 1 x MADI optical/coaxial,Dynamic Range AD: 113 dB RMS unweighted, 116 dBA,THD AD: < -110 dB (< 0.00032 %),THD+N AD: < -104 dB (< 0.00063 %) Crosstalk AD: > 130 dB,Input level for 0 dBFS: +24 dBu, +19 dBu, +13 dBu,Frequency response AD, -0.1 dB: 10 Hz - 23.2 kHz (sf 48 kHz),Frequency response AD, -0.5 dB: < 5 Hz - 45 kHz (sf 96 kHz) Frequency response AD, -1 dB: < 5 Hz - 80 kHz (sf 192 kHz) Sample rates: 44.1, 48, 88.2, 96, 176.4, 192 kHz, variable (Sync/WC),Jitter: Typical < 1 ns for internal, Word Clock, ADAT and MADI input Jitter sensitivity: all PLLs operate error-free even at 100 ns,Jitter suppression: > 30 dB (2.4 kHz),Power supply: Internal switching mode PS, 100V - 240V AC, 60 Watt Dimensions: (WxHxD) 483 x 88 x 200 mm)as per Department incharge 154 Supplying of Determination of Plancks constant(1. 1 0-2V D.C. at 20mA Variable Power Supply. 1.2 Digital Panel meter 3½ digits range 2mA. 1.3 Digital Panel meter 3½ digits range 2 volt 02 Lamp House: 100W Bulb with stand 03 Vacuum Type Photo Cell : Mounted in a Iron box. 04 Three different colour optical filters 05 Adequate no. of patch cords stackable 4mm spring loaded plug length 50cm. 06 Strongly supported by detailed Operating Instructions, giving details of Object, Theory, Design procedures, Report Suggestions and Book References.) as per Department incharge 155 Supplying of Determination of Energy Band Gap using Four Probe method(Product Specification:Type-Energy Band Gap Usage/Application-Laboratory,Connector-4mm Banana Socket Frequency-50Hz) as per Department incharge 156 Supplying of Determination of Hall coefficient and Hall angle in Hall-effect(Product Specification,Display Type-0-20V DC, 0-5 A, digit LED, Primary safety socket,4mm Electro Magnet Coils 500 T, Voltage resolution -0.1V,Current Resolution 0.1 A) as per Department incharge 157 Supplying of Determination of magnetic susceptibility using Guoys method(Usage/Application Physics Laboratory Type Of Instruments-Magnetic Susceptibility Gouys Balance Method Experiment Setup,Power-230V , 50Hz, +-10% Display Type-LED Type) as per Department incharge 158 Supplying of Study of absorption pattern of a given sample using FTIR spectrometer(Product Specification,Detector-High performance pyroelectric infrared detector,Weight-15 kg Software-1,Voltage-100-240V AC,Electronic System-24bit A/D converter at 500KHz, USB 2.0,Wavenumber Range-7800~350 cm-1Power-100-240V AC,50/60Hz,Signal Noise Ratio-30000:1 (resolution@4cm-1 , sample and background scan for 1 min@2100cm-1 ),Light source-Long life, steady state infrared emitter Beam splitter-coated KBr,Resolution-1 cm-1,Dimension-430mm x 360 x200) as per Department incharge 159 Supplying of LCD Projector and smart board (Product Specification,Projection Distance-<1 m Resolution-WXGA,Lamp Life-5000/9000/10000 HOURS Screen Size-100,Display Type-LCD,Dimensions-400X367X149MM Connectivity Type-Dual HDMI, HDMI,Brightness-2000-4000 Lumens Color-White) as per Department incharge 160 Supplying of Desktop(ntel Core I3/ 10th Gen/ 4GB RAM/ 1TB HDD/ DOS/ NO DVD/ 19.5 Inch Monitor/ 1 Year Warranty) as per Department incharge 161 Supplying of Printer(Product Specification,Printer Type-Ink Tank Color Output-Color,Print Speed-22 ppm,Paper Size-A4,Dimension-403 x 369 x 150 mm,Weight -6,Warranty-One Year or 50,000 pages which ever is earlier) as per Department incharge 162 Supplying of Printer (Product Specification Printer Type-Inkjet Color Output-Color | B&W,Print Speed-10,Paper Size-A4,Connectivity-USB,Dimension-377 x348 x179,Weight-3.9 Print Volume-any)as per Department incharge 163 Supplying of XEROX Machine (Product Specification,Functions-Photocopy,Supported Paper Size-A3,Supported OS-Windows 10 Color Output-Black & White,Number Of Trays-1,Item Color-Black & WhitePrint Speed-22 PPM,Weight-40 kg,Print Technology-Laser Input Tray Capacity-350 sheets,Warm-Up Time-5.6 Sec,Duty Cycle-80000 / Month,Resolution-600 x 600 dpi Connectivity-Ethernet & USB,Duplexing-Yes)as per Department incharge 164 Supplying of computer system with internet connection,PC Specifications to be followed :Processor Intel Core i5(10th Gereneration or newer ),RAM-8 GB or Higher HDD:512 GB,SSD,Monitor 24 LCD Monitor .OS:Windows 10 Professional ,Anti virus:User Licence for one year as per Department incharge 165 Supplying of Laptop (with Internet connection),Processor intel Core i5(11th Generation or newer),RAM 8 GB or higher HDD:512 GB,SSD Monitor 14 screen ,OS Windows 10 Professional ,Antivirus :User Licence for one year 166 Supplying of LCD Projector (Specification-Brightness:2000-4000 Lumens,Resolution-FULL HD 1080P,Connectivity Type-Dual HDMI, HDMI Display Type-DLP,Power Supply-100-240V Portable-Yes) as per Department incharge 167 Supplying of Smart Board (Frame Material-Aluminium Usage/Application-School, Education, etc,Effective Touch Area-72 x 48 inch Material-Ceramic Input Method-USB Power Consumption-150 - 220 W,Shape-Rectangular) as per Department incharge 168 Supplying of MS Suite Software(Specification-Microsoft Office Software,Operating System:For Windows,Brand:Microsoft )as per Department incharge 169 Supplying of Adobe Photoshop Software(Specification -Graphic Design and Photo editing,Licence-1 yea) as per Department incharge 170 Supplying of windows10 OS Software(Specification-License Duration-Life Time,Architecture-32/64 Bits,Operating System For WindowsAlso Provides,Windows Operating System,Provide Installation Service-Yes Support 24/7 (Live Rep)) as per Department incharge 171 Supplying of Laptop of 11th Generation intel core i3,1115G4 processor (6 MB Cache up to 4.1GHZ)windows 10 Home Single language English,intel UHD Graphics with shared graphics memory 8GB ,8 GBX1,DDR4,3200 MHZ,512 MB,2 PCLeNVMe Solid state drive pebble (Top colour is pebble colour,Base and palmrest are black colour as per department incharge 172 Supplying of Desktop of 10th Generation intel core i5-10500T (6 CORE,12MB Cache 2.3GHZ to 3.8GHz,35W ),Windows 10 Pro (64 Bit )English,intel integrated graphics),8GB ,1X8 GB,DDR4 non-EC0C Memory,2.5 inch TB 7200 RPM ,SATA Hatd disk drive 5480AJO 23.8 FHD 1920X10080 ips non touch,Antiglare camera,integrated graphics,Bronze 1505w PSU as per department incharge 173 Supplying of Printer (Specification:Item Weight-12 Kg,Package Dimensions-60 x 56.5 x 38 cm,Connectivity Type-Wi-Fi Operating System-Windows)as per department incharge 174 Supplying of Fumehood(Specification:Type-exhaust,LED-Tube fitting,Power-230 volt,Working Top-Granite ,MOC-GI with PU coated Storage includedas per department incharge 175 Supplying of electronic balance(Specification -Usage/Application-Laboratory,Accuracy-0.01%,Calibration-Fully Automatic,Type Of Weighing Scale-Digital,Voltage-110-220 V Mounting Type Desktop) as per department incharge 176 Supplying of Magnetic stirrer Magnetic stirrer Hot plate (Specification-Weight-2.3 kg,Timer -999 minutes,Temp. Accuracy-+-1 Deg.C(<100 Deg.C)+-3 Deg.C(<300 Deg.C),Dimensions LxWxH (mm)-230 x 180 x 120,Max.Temp. (Plate Surface) 300 Deg.C,Power supply-AC 220V / 50 Hz,Top Plate Size 135 x 135 mm,Display-LCD,Max. Volume (ml) 2000 ml,Speed (RPM)-1250 RPM Plate Material Steel per department incharge 177 Supplying of HOT Air oven of made inner material-stainless steel,Outer material -mild steel ,Surface treatement -Powered coated ,Sizes-Different sizes,Gravity conviction type-Double wall.Mechnical conviction -Triple wall as per department incharge 178 Supplying of colourimetry , Ery colour colorimeter industrial and research purpose stability( Product Specification:Material-Aluminium Alloy,Automation Type Automatic,Brand -DD-LAB ,Dimension-210 x 160 x 80 mm,Display Type-Dual Digital DisplayLight Source-Highly Accurate Laser Source,Stability- + 0.02 O.D. Per Hour Volume 1 ml. minimum,Filters layer-Built in 9 Digital filters 30,000 hours Life,Weight-1.5 Kg,Battery Backup-6 V Ni CD Re-chargeable Battery,Detector Silicon Photo-diode,Display Model Absorbance & Wavelength,Filter Wavelength 680 NM Country of Origin Made in India) as per department incharge 179 Supplying UV-Vis Spectrophotometer Fully touch screen portable UV Spectrophotometer shimadzu model name:UV 1900,Brand :shimadzu,Display =fully touch screen,Type-portable,size 450x501x244 as per department incharge 180 Supplying of potentiometer ,Range-0 to 1999.9mv,Resolution-1 mv,Repeatability -1mV,Accuracy +1 mv+ digit,Input impedency-10ohms,operating temperature 10 to 50 degree Celsius,Display 1/2 digit 0.5 seven segment LED Display indication,Power-230V+10,50hZ,Dimensions 76x275x170 mm,weihjt 2 kh as per department incharge 181 Supplying of Conductivity meter,LT 26 Deluxe conductivity meter,Product details:Model no-LT-26,Brand -Labtronics,Usage-Laborataty,Display type 3.5 Digit LEDas per department incharge 182 Supplying of Online COD/BOD Detector analyzer warer quality monitoring probe,Measure range-0-200/0-1000mg/l,Resolution -1 mg/l ,Accuracy +5%F.s ,Under pressure-1 bar,Power supply -12-24V DC ,Temperature range 0-45 degree ,Production leve;-IP68 as per department incharge 183 Supplying of melting point appratus,Temperature renge -2 degree above ,Readability 1 degree ,Display -3 Digit LED,Heating rate control-Electronic,Temperatre sensor PT-100as per department incharge 184 Supplying of Ph meter Labrtonics,Range:0-14pH,Resolution:0.01pH,Accuracy:0.01pH(Relative),Temp comp:Automatic wvith temp probe,Buffer:Manuals with keys as per department incharge 185 Supplying of Spectrum 3 FT-IR Spectrometer,Model no.-LI280127,Wave length -11000-30 cm-1 as per department incharge 186 Supplying of Stopwatch NIVIA 600 plastic(Product Specification:Color-Black,Usage/Application-Sports,Time Display 12/24 hour display for user option,Material-Plastic,Dial Shape-OvalMaximum Counting-23 hours 59 minutes 59 secondsas per department incharge 187 Supplying of Digital Bomb Calometer(Specification-Auto Off Automatic,Frequency-50 Hz,Voltage-230-280 V,Operating Time Per Test 10 minutes,Power Source Electric(Automatic) as per department incharge 188 Supplying of Microprocessor viscometer ,Product details: Measuring range-101x105mpa,,Spindles-4 Spildles,Rotor speed(rpm)-6/12/30/60 rotor speed rpm as per department incharge 189 Supplying of Flame photometer,Product details:Application-Laboratory use,industialuse,,weight 705kg ,Curve fit accuracy,Resolution-0.1ppm/meq as per department incharge 190 Supplying ofwater purification system,Resolution-18.2 M ohm cm at 25 degree C,Weight-19.5kg,Frequency-50-60Hz as per department incharge 191 Supplying of Refrigerator of 7.5kg fully Automatic Top Load washing machine (Hard water wash,Grey,5 star,10 years warranty as per department incharge 192 Supplying of water bath ,unstirred water bath s ,Digital info Water bathdigital,18L amb+5 tp 99 degree C includes clear lid and base trayas per department incharge 193 Supplying ofmini rotary shakers 50to 400RPM,features-220/230 V ac,Power supply-50-60Hzas per department incharge 194 Supplying of Magnetic stirrer- capacity 5 litre Spinit Digital Magnetic Stirrer Features-Type of Product-Magnetic stirreras per department incharge 195 Supplying of Digital ultrasonic cleaners (Specification: tank capacity 4 L, ultrasonic power 100W, Heating, Power-100W, time setting 1-99 min, heating temp up to 80 degree, in and out both in ss, with digital timer auto stop of sonication. 230V AC +-10% 50HZ. Tank size 300x150x100mm, overall size 330x180x240mm.supplied with basket and Lid.) as per department incharge 196 Supplying of Calomel electrode (Product Specification:Packaging Type-Box.,Length-120 mmUsage-Electrochemical Study(Laboratory))as per department incharge 197 Supplying of Pt-wire counter electrode (Product Specification Electrode Diameter-0.5 mm,Power Source-10A) as per department incharge 198 Supplying of UV-LAMP Cabinet(Product SpecificationSize/Dimension-15 X 12 X 10 (H) Light Source-3 NOS , SHORT WAVE -254nm-1no, LONG WAVE-365nm, VISIBLE LIGHT,Material-MILD STEEL,Voltage 230 V AC) as per department incharge 199 Supplying of Magnet (Magnet Grade-N48 Shape-Cup & Pot,Material Neodymium,Dimensional Tolerance+-0.05 mm,Plating / Coating-Ni-Cu-Ni Colour-red,Surface Gauss 3000 Gauss,Maximum Working Temperature (Deg. C)-230 Deg. C as per department incharge 200 Supplying of Micro Centrifuge tube(Specification: Usage/ApplicationLaboratory Analyzers,Material,Polypropylene Color-White,Pack Contains--20 Packet / carton & 500 pcs / packet,Shape-Conical,Length-4.1 cm,Inlet Diameter-1.3 cm Capacity2 ml)as per department incharge 201 Supplying of Micropiprtte(10-100uL),(Product Specification Capacity-10 ml,Volume Increment -0.1 microlitre Material-Glass,Autoclavable-Yes)as per department incharge 202 Supplying of Micropiprtte(10-1000uL),( Product Specification Material-Plastic,Capacity-Up to 1000ul,Color-Transparent Usage/application-Chemical Laboratory) as per department incharge 203 Supplying of printer-Black and white print ,scan,copy all in one printer Product Specification Print Speed-Up to 18ppm / 19ppmLaser Printer,Color Output-Black & White,Print Technology LaserjetUsage/Application-Printing,Supported Paper Size-A4 Compatible Operating Systems1,Windows 8,Windows 7,Windows Vista,Windows XP,Windows 2000,Mac OS X 10.4 - 10.8,Linux*3 Print Resolution-Up to 600 x 600DPI,1 200 (Equivalent) x 600DPI,Print Language-UFR II LT Dimension-372 x 371 x 254mm (With the Cassette Opened)Weight(W/O CRG)-7.6kg,Monthly Duty Cycle-8000 Pages Power Consumption 960W(Maximum),First Printout Time7.8s / 7.7s (A4 / LTR),Zoom 50 - 200% in 10% Increments Refill Type Toner Cartridge,Internal Memory 64 MB Printer Language UFR II LT (Host Based),Paper Weight 60 to 163g/m2 (Cassette),Copy Speed Up to 18 / 19Cpm (A4 / LTR) Halftones 256 levels,Copy Resolution 600 x 400 DPI Display 7 - Segment,1 - Digit LED as per department incharge 204 Supplying of printer-colour print ,scan,copy all in one printer (Specification :Functions-Print | Scan | Copy,Technology-Inkjet Color output-Color | B&W,Connectivity-Wireless(Wi-Fi) Usage-For Office ,Paper size-A4,Print speed upto 40 pages/min)as per department incharge 205 Supplying of photocopier branded fast print 50ppm high image resolution superior print quality,fast scan up to 50ppm A4 Monocolouras per department incharge 206 Supplying of LAN.Networking,cabling,switches,Wi-Fi points(10 points in each department) as per department incharge 207 Supplying of installation of Printer (Black and white),Printer( colour),Photocopier and LAN,Networking,Cabling,Switches,Wifi Points as per department incharge 208 Supplying of RS+ TT7519RS,RS75+ comes with 75 diagonal length with 3 GB RAM and 48 GB ROM,Slim Glare ,H7 touch surface hardness,Light weight for easy installation,Media suits for Annotation software Bundled with education apps,Office suits ,Great writing experience,Object recognition-First /palm /fine pen ,Touch points -20 points under andriod ,178 degree viewing angle ,IR Touch 15000 14-01-20241 contrast ratio as per department incharge 209 Supplying of Freightof RS+ TT7519RS,RS75+ comes with 75 diagonal length with 3 GB RAM and 48 GB ROM,Slim Glare ,H7 touch surface hardness,Light weight for easy installation,Media suits for Annotation software Bundled with education apps,Office suits ,Great writing experience,Object recognition-First /palm /fine pen ,Touch points -20 points under andriod ,178 degree viewing angle ,IR Touch 15000 14-01-20241 contrast ratio) as per department incharge 210 Supplying of wall mount (Dimension long:Telescopic Adjustable CCTV camera mounting bracket -Color: Beige Universal Camera Bracket, Heavyduty weatherproof iron bracket fits mostbrands of outdoor camera housing,Iron stand Platsic APPLICATION: Ideal for indoor outdoor dome cameras, Security Camera Mount Bracket, high quality with professional design,more stable and reliable.Hidden hole: Cable can feed thru L bracket tothe housing thus provide cable protection Outdoor and Indoor Use.)as per department incharge 211 Supplying of Camcorder Compact full HD ENG Camera with 20X zoom and 5 axis image stabilization. 20X optical zoom (26.8mm, F/1.8-576MM, F/2.;28.8MM, f/1.-576mm). 5 axis image stabilization. Support formats: full HD50P/60P, AVCHD/MP4;SD card slots 2 35mm film camera equivalent when dynamic IS is turned on with Tripod as per Department Incharge 212 Supplying of Video capture and video capture card (Product Specification:Converter type-USB,Material:Metal,Audio Jack:3.5 mm,HDMI Version:Hdmi-1.4,Audio:44100 AU,Video:Full HD Frame:48000 Resolutions)as per department incharge 213 Supplying of UPS(1KVa)(Product Specification: Type-Online UPS,Capacity-1 kVA,Configuration-1 Phase IN - 1 Phase OUT,Protection-OverVoltage,Form Factor-Tower Model Back Up Time-20- 30 Mins,Frequency-40 ~ 70 Hz (auto-sense) Usage/Application All) as per department incharge 214 Supplying of Studio light-125watt,5 LED BULBS consisting of 25watt bulb(Colour Temperature:5500 kelvin)as per department incharge 215 Supplying of Live streaming software for live streaming or live telecast as per department incharge 216 Supplying of Cables,installation,SSD Card(SAMSUNG VNAND SSD 850 EVO 2.5 250GB SATA III 3-D Vertical Internal Solid State Drive (SSD) MZ-75E250B/AM) as per department incharge 217 Supplying of complete making soundproof class(20*20 feet Room) as per department incharge 218 Supplying of RFID Tags RFID Book Lables(specification: Language ‏ : ‎ English,Simultaneous device usage ‏ : ‎ Unlimited Text-to-Speech ‏ : ‎ Enabled,Screen Reader ‏ : ‎ Supported Enhanced typesetting ‏ : ‎ Enabled,X-Ray ‏ : ‎ Not Enabled,Word Wise ‏ : ‎ Not Enabled) as per department incharge 219 Supplying of Anti theft stickers with the university logo(Polycarbonate 175 Microns Matt Finish) as per department incharge 220 Supplying of Middleware Application Desktop(writing and read tags) as per department incharge 221 Supplying of RFID Staff station or desktop reader (used for Tagging of books and circulation) operations through RFID as per department incharge 222 Supplying of Integration with software and Training of complete RFID System as per department incharge 223 Supplying of Data Encoding,Booking Tagging and Registration per book as per department incharge 224 Supplying of RFID Secuity Gates (2 pedestals - 1 gate),RFID Secuity Gate(Provide Installation Service-Yes,Support-24/7 (Live Reporting Language Support-English) as per department incharge 225 Supplying of Automated book drop box (ntegrated RFID Reader • Approx. 250 Books Receiving Cart (Movable) • Client Software for Checking-in Facility and communicating with LMS with provision for E-mail/SMS confirmation • Has automatic hutch which should open only on valid RFID tags and close once the book has been accepted to prevent the patrons from removing checked in books. • Communication with any LMS Software through SIP2/NCIP protocols • Compliant with internationally recognized standards for RFID based library self-services systems. • Book Drop can display item ID once item is returned. • Enabled with necessary items i.e.: Branded CPU etc. • 15” or higher LCD/LED Touch Screen Monitor. • Ethernet High Speed Receipt Printer (Reputed/Branded) • Customizable Design matching the library aesthetics; Contemporary and attractive. • Design is such that there is not damage to the dropped books. • Library Ethernet network and wireless network compliant. • Optional Features: Fingerprint Scanner, Smart Card Readers etc) as per department incharge 226 Supplying of 5KVA Invertor -online UPS with battery back up 100Mah battery (8 units)(Product Specification,Capacity-1100 Voltage-130V ,Rated Input Power-5 KVA,Display-Digital Type-Square Wave Inverter Country of Origin) as per department incharge 227 Supplying of LAN,Switches,Necessary cabling,casing,power supply port including cables as per department incharge 228 Supplying of Installation charges of RFID Tags,Anti-theft sticker,Middleware Application Desktop,RFID Staff statio,Integration of software,Data incoding books,RFID Secuirty Gates,Automated Book Drop Box,Cabling,Casing,Wiring,Switches,LAN as per department incharge 229 Supplying of Air conditioning 1.8Ton heavy duty AC (minimum 3 star rating,Coil material -copper,Power consumption-1950W,Power Requirement -AC 130-285V, 50Hz) as per department incharge 230 Supplying of Desktop,i5 processor ,7th Generation,500GB HDD,4GB RAM,23.8 INCH LED Backlit Monitor,Full HD IPS Panel(Brand-HP,Dell,Acer) as per department incharge 231 Supplying of Headphone with built in microphone,(Communication-Wired) as per department incharge 232 Supplying of 75 diagonal length with 3 GB RAM and 48 GB ROM ,Slim frame anti glare glass.3M Antiglare ,H7 Touch surface hardness,Light weight for easy installation as per department incharge 233 Supplying of Dedicated server-HPE Proliant DL 380,Gen 10 5218.2.3GHz 16core ,1P-32GB-R P408ianNC 8SFF 800WPS Server,Intel xeon G5218 Kit for DL 380,Gen 10 as per department incharge 234 Supplying of 5.5KVA Inverter with battery backup,Microtek inverter,online UPS ,65Mah battery(16 unit )-Exide as per department incharge 235 Supplying of Freight Transportation Charges of Desktop,Headphone,LAN Switches,4K-OPS,Dedicated server,5.5 KVA Inverter with battery back up and Air conditioner as per department incharge 236 Supplying of 86 Diagonal interactive display,3 GB RAM,48 GB ROM,4K Display Android model,Slim framenAnti glare Glass,H7 Touch Surface hardness ,Light weight for easy installation ,Media Suits for Annotation softwatr bundled with education Apps as per department incharge 237 Supplying of 4k OPS i5,7th Gen,8GB RAM,128 GB SSD as per department incharge 238 Supplying of play mounting including white board & Green board,Material post formed ply,Size 15ft(length)x7ft(ht) with green board for chalk,whiteboard for marker and cupboard as per department incharge 239 Supplying of UPS (1KVa,Phase-Single phase.Back up Time 10-20 min,Frequency-50Hz) as per department incharge 240 Supplying ofTraining and installation of 86 diagonal interactive display,4k-OPS,Play mounting including white board & Green board and UPS of 1KVA as per department incharge 241 Supplying of Digital Podium PTGN 500 Windows 8.1 LCD ,Electronic Lectern,On site OEM Warranty in 3 yearsas per department incharge 242 Supplying of PA System sound system with amplifier 350 watt ,30 watt speaker (4 nos) as per department incharge 243 Supplying of wireless mic Dual channel cordless microphone as per department incharge 244 Supplying ofTraining and installation of Digital Podium,86 Diagonal interactive display (4k display),4K-OPS,Play mounting including white board and green board,5KVA invertor,PA System and wireless mic as per department incharge 245 Supplying of Desktop :- 1).i5 Processor, 7th Generation, 500GB HDD, 4GB RAM, 2).23.8 inch. LED backlit Monitor Full HD IPS Panelas per Department Incharge 246 Supplying of 55 LED Display for CCTV Branded LED Display as per department incharge 247 Supplying of CCTV Camera IP based CCTV camera,2 TB Space with NVR with necessary accessories as per department incharge 248 Supplying of Stagmometer as per Department Incharge 249 Supplying ofViscometer as per Department Incharge 250 Supplying of Beaker-50ml as per Department Incharge 251 Supplying of Beaker-100ml as per Department Incharge 252 Supplying of Beaker-250ml as per Department Incharge 253 Supplying of Beaker-500ml as per Department Incharge 254 Supplying of Beaker-1000ml as per Department Incharge 255 Supplying of Buchner Funnel 3 as per Department Incharge 256 Supplying of Buchner Funnel 6as per Department Incharge 257 Supplying of Burette-50ml as per Department Incharge 258 Supplying of Chromatography column 1x18 with stop cock as per Department Incharge 259 Supplying of Conical flask-100ml as per Department Incharge 260 Supplying of Conical flask-250ml as per Department Incharge 261 Supplying of Conical flask-500ml as per Department Incharge 262 Supplying of Conical flask-1000ml as per Department Incharge 263 Supplying of Flat Bottomflask-500ml(Round) B-24 socket as per Department Incharge 264 Supplying of Round bottom flask-50ml Joint B-24 as per Department Incharge 265 Supplying of Round bottom flask-100ml Joint B-24 as per Department Incharge 266 Supplying of 3 neck RB flask B-29,B-19.as per Department Incharge 267 Supplying of Condenser Spiral B-24 and, B-19 as per Department Incharge 268 Supplying of Condenser Spiral B-24 and, B-24 as per Department Incharge 269 Supplying of T-type tube as per Department Incharge 270 Supplying of Rubber Cock No. 10 as per Department Incharge 271 Supplying of Specific Gravity hydrometer 800-1000 as per Department Incharge 272 Supplying of Specific Gravity hydrometer 100-1200 as per Department Incharge 273 Supplying of Universal hydrometer 1000-2000 as per Department Incharge 274 Supplying of Measuring Cylinder-10ml as per Department Incharge 275 Supplying of Measuring Cylinder-50ml as per Department Incharge 276 Supplying of Measuring Cylinder-100ml as per Department Incharge 277 Supplying of Measuring Cylinder-500ml as per Department Incharge 278 Supplying of Measuring Cylinder-1000ml as per Department Incharge 279 Supplying of Measuring Cylinder-2000ml as per Department Incharge 280 Supplying of Measuring flask-100ml as per Department Incharge 281 Supplying of Measuring flask-500ml as per Department Incharge 282 Supplying of Measuring flask-1000ml as per Department Incharge 283 Supplying of Pipette-0.5ml as per Department Incharge 284 Supplying of Pipette-2ml as per Department Incharge 285 Supplying of Pipette-5ml as per Department Incharge 286 Supplying of Pipette-10ml as per Department Incharge 287 Supplying of Pipette-25ml as per Department Incharge 288 Supplying of Separating Funnel-250ml B-24/B-24 as per Department Incharge 289 Supplying of Spatula Flat Spoon 6as per Department Incharge 290 Supplying of Spatula Flat Spoon 5as per Department Incharge 291 Supplying of Stop Cork 2wayas per Department Incharge 292 Supplying of Silica crucible-15ml without Lid as per Department Incharge 293 Supplying of Silica crucible-25ml without Lid as per Department Incharge 294 Supplying of Stalagmometer Straight Graduated as per Department Incharge 295 Supplying of Chemical thermometer 10c-110c as per Department Incharge 296 Supplying of Chemical thermometer 0c-250c as per Department Incharge 297 Supplying of Tiration flask-100ml as per Department Incharge 298 Supplying of Tiration flask-250ml as per Department Incharge 299 Supplying of Tongs crucible S.S.8 as per Department Incharge 300 Supplying of Test tube holder as per Department Incharge 301 Supplying of Filter Flask-500ml as per Department Incharge 302 Supplying of Filter Flask-1000ml as per Department Incharge 303 Supplying of Watch glass 3 as per Department Incharge 304 Supplying of Watch glass 4 as per Department Incharge 305 Supplying of Watch glass 6 as per Department Incharge 306 Supplying of Wire gauge150x150mm as per Department Incharge 307 Supplying of Tripod stand 8 as per Department Incharge 308 Supplying of boiling Test tube 1x8as per Department Incharge 309 Supplying of boiling Test tube 2x8as per Department Incharge 310 Supplying of Reagent Stickers 2x1 as per Department Incharge 311 Supplying of Ordinary Filter paper as per Department Incharge 312 Supplying of Reagent bottles-250mlas per Department Incharge 313 Supplying of Rubber cork as per Department Incharge 314 Supplying of Rubber tube 6mm as per Department Incharge 315 Supplying of Solid Reagent bottle-125mlas per Department Incharge 316 Supplying of Stopwatch plastic body as per Department Incharge 317 Supplying of Test tube stand 12 holes as per Department Incharge 318 Supplying of Thermometer 360 as per Department Incharge 319 Supplying of Test Tube 6mmx15cmas per Department Incharge 320 Supplying of Test Tube 10mmx10cm as per Department Incharge 321 Supplying of China dish 3 as per Department Incharge 322 Supplying of China dish 4 as per Department Incharge 323 Supplying of Brushes for Test Tube as per Department Incharge 324 Supplying of Brushes for Burette as per Department Incharge 325 Supplying of Brushes for Conical flask as per Department Incharge 326 Supplying of LPG gas burner as per Department Incharge 327 Supplying of Condenser Coil 12 as per Department Incharge 328 Supplying of Receiving adopter with vacuum outlet as per Department Incharge 329 Supplying of Plastic Wash bottle-500mlas per Department Incharge 330 Supplying of Pastel and Mortar 3 as per Department Incharge 331 Supplying of Pastel and Mortar 4 as per Department Incharge 332 Supplying of Pastel and Mortar 6 as per Department Incharge 333 Supplying of China Clay 2 as per Department Incharge 334 Supplying of China Clay 3 as per Department Incharge 335 Supplying of China Clay 4 as per Department Incharge 336 Supplying of Petri Dish 3(Borosil) as per Department Incharge 337 Supplying of Petri Dish 4(Borosil) as per Department Incharge 338 Supplying of Distillation Set-Complete flask-500ml as per Department Incharge 339 Supplying of Distillation Set-Complete flask-1000ml as per Department Incharge 340 Supplying of Thermometer Pocket B-14 as per Department Incharge 341 Supplying of Sintered Glass Funnel-25ml as per Department Incharge 342 Supplying of Air Condenser 12 as per Department Incharge 343 Supplying of Burette Stand with Clamp as per Department Incharge 344 Supplying of Cork borer as per Department Incharge 345 Supplying of Capillary Tube for melting point as per Department Incharge 346 Supplying of Dessicators 6 as per Department Incharge 347 Supplying of Dessicators 8 as per Department Incharge 348 Supplying of Dropper with Rubber teats 6 as per Department Incharge 349 Supplying of Dropper 4(Borosilicate glass) as per Department Incharge 350 Supplying of Dropping bottle-125ml as per Department Incharge 351 Supplying of Funnel Stand as per Department Incharge 352 Supplying of Fusion Tubeas per Department Incharge 353 Supplying of Glass Rod as per Department Incharge 354 Supplying of Glass Tube as per Department Incharge 355 Supplying of Stopwatch Steel body as per Department Incharge 356 Supplying of Magnetic Stirrer as per Department Incharge 357 Supplying of Rubber Gloves as per Department Incharge 358 Supplying of Reagent as per Department Incharge 359 Supplying of Sandbath as per Department Incharge 360 Supplying of Tissue Paper(Local made) as per Department Incharge 361 Supplying of Double Beam PC Microprocessor UV-VIS Spectrophotomet erMake:Systroni cs Model: 2202 PC Based Double Beam Automatic source optimization ,Base line calibration & Cell optimization 200 - 1100 nm Range2. 0 nm Bandwidth%T. Abs. Conc . (K factor. Multi standard ). Multi component measuring modesSingle Wave length, Multi Wave length Scan (with multi scan facility). Time Scan. Kinetic scan operating modes Automatic 5 position sample changer Single Position 50 /100 mm Cuvette Holder (Optional) as per Department incharge 362 Supplying of Refrigerated Centrifuge,(Specification:Speed:- 20000 Max.,RCF:- 37570 Max.,Lowest Temp:- -8,Noise:- <-60db)as per Department incharge 363 Supplying of Refrigerated Centrifuge Essential accessories Required:. With angle Heads (with polypropylene tubes)Model- R-248M 24xl.5 ml as per Department incharge 364 Supplying of Refrigerated Centrifuge 2. Voltage stabilizer:- 03 KW Servo controlled Voltage Stabilizer, input 170 volts to 260 volts, output 220 volts to 240volts as per Department incharge 365 Supplying of PCR machine(Specification- Well block, Gradient, temp. range 4° - 99-irC, memory capacity 10000 protocols , display 7inch,volume capacity I 0- 100 μL , preloaded protocol, temperature accuracy ±0.2°C@99°C, with PCR wizard as per Department incharge 366 Supplying of SOS PAGE unit and Western Blot apparatus along with power bank -Mini-TBC electroph_oretic transfer cell, includes: Mini 01P-4 cell tank and lid with cables, buffer, Mini transfer module, gel holder cassettes, 4 fiber pads, cooling units, instructions, Western blot unit, compatible power bank as per Department incharge 367 Supplying of pH Meter With electrode(Type of PH Mater - Portable,Ph Range:0-14,Resolution-0.01pH,compensation-0 to 80 degree celsius) as per Department incharge 368 Supplying of Deep fridge(It is used to store chemicals and preserve samples at very low sub-zero temperatures or below)as per Department incharge 369 Supplying of Autoclave (Vertical)Size- 400 x 600mm ,;Capacity- 75Ltr as per Department incharge 370 Supplying of Hot air oven (Sterilization) as per Department incharge 371 Supplying of Incubator Shaker-Growth and enumeration of microbes (Broth cultures) as per Department incharge 372 Supplying of Horizontal Laminar air flow(Sterile environment Size 4X2)as per Department incharge 373 Supplying of Horizontal Agarose gel electrophoresis unit with gel caster and Power pack Separation of macromoleculeas per Department incharge 374 Supplying of Vortex mixture-To mix content of test tubes and microfuge tubes. as per Department incharge 375 Supplying of Ultrapure Water Purification System:MiliQ Water For distill wateras per Department incharge 376 Supplying of Micropipets - 0.1μL-2.5μL 0.5μL-10.0μL 10.0μL-l00μL 20.0μL-200μL l00μL-l000μL as per Department incharge 377 Supplying of Quebec Colony Counter -Count the microbial colonies as per Department incharge 378 Supplying of Light Microscope (General) 10X,20x, 45x, l00x Visualize microorganisms as per Department incharge 379 Supplying of Bifocal microscope with illuminators, Camera attachment and computer Visualize microorganisms and microgrphy as per Department incharge 380 Supplying of Magnetic stirwith Hotplate and magnetic beads To stir the liquids , preparation of solution as per Department incharge 381 Supplying of Heating mantle For heating round bottomed flask/distillation flask as per Department incharge 382 Supplying of Microwave oven To heat liquids instead of flaming. Samsung/ LG 20 Ltrs as per Department incharge 383 Supplying of Glass Dessicators Used for dessication as per Department incharge 384 Supplying of Fluorescence microscope A fluorescence microscope is an optical Microscope that uses fluorescence and phosphore scence instead of,or in addition to, reflection and absorption to study properties of organic or inorganic substances as per Department incharge 385 Supplying of Electronic Analytical Balance It is used to weigh small quantities of chemicals and samples precisely and quickly. Readability- 1 mg (0.001 g) Cap.- 420gm as per Department incharge 386 Supplying of Electronic Top pan Balance- Readability- 0.1 g Cap.- 2 kg.as per Department incharge 387 Supplying of Double Distillation Unit ,.Approx output: 2 Lit/hrs Wattage:3.3 .KW With safety Cutoff Device Water Stills are carefully designed to produce high purity pyrogen free distiiied water. The water still comprises ofborosilicates glass horizontal typeboiler, coil condenser, constant level device, silica sheathed heaters, along with stand and clamps. All parts are replaceable. pH/conductivity:6-7 / 1-2 μSiem forsingle, 6-7/0.8-lμS/cm for double distilled water as per department incharge 388 Supplying of Microtome-5286(Product Specification Minimum Setting Value-0.5 um,Object Feed-28 mm,Vertical Stroke-60 mm,Specimen Orientation X and Y Axis Universal 8 Degree Trimming Thickness Range-1 um-100 um Operation-Automatic. (Motorized Feed & sectioning and Emergency Stop Provided),Sectioning Speed-0-400 mm/sec.,Specimen-Orientation Z Axis-Upto 360 Degree,Retraction Value-Adjustable Max Specimen Size-50 x 50 mm,Section Thickness Range-0.5 um-60 um)Senior rotary microtome as per Department incharge 389 Supplying of Cryostat -(Product Specification Section Thickness Range-0.5 Micron to 100 Micron (with the increment of 0.5 Micron, 1 Micron, 2 Micron, 5 Micron) Power Supply-220v,Dimension-750mm x 750mm x 950mm (approx) Weight -123 kg (approx),Remote Control-Optional,Sectioning Mode-Single step mode/ Continuous mode Hand Wheel Control-Feather Touch Keypad/ Foot Switch/ Remote Control (optional),Sterilization-U.V-C Sterilization,Cooling down time Up to -30 DegreeC-2 Hour 30 Min Specimen Retraction setting Range-5 Micron to 100 Micron (with increment of 5 Micron),Compressor-Dual Compressor,Cryo Chamber Temp. Adjustable -1 DegreeC to -30 DegreeC Block Holder Head Temperature-Adjustable -1 DegreeC to -35 DegreeC Illumination-LED Lamp)Ultimate usico fully automatic cryostat as per Department incharge 390 Supplying of ELISA -Vet scientific(Specification-Product Specification Automation-Semi Automatic,Assays Performed-ELISAs, Immuno Assays Plate Format-96 well,Optical System Filter-based Detection Method-Absorbance,Number Of User Programs 42 Storage-100000 Results,Filter Positions-8 Display Type-Touch Screen Packaging Type-EXPORT QUALITY,Testing Speed-3 second Type Of Filter 405,450,492, 630,Power Source-115/230 V AC, 50Hz,Weight-9 Kg,Is It Portable-Non Portable, sample Type-Serum, Plasma, Urine, CSF, Whole Blood,sample Volume Range-10-100 Interface-RS232/ USB) as per Department incharge 391 Supplying of Calorimeter -A VI Digital (A VI Scientific,Frequrcy:50Hz,Voltage:230-280V,operating time per test-10 min) as per Department incharge 392 Supplying of HaemometerSahli type-Microsidd (Specification:Amber coloured glass bottle -1 No.,Glass Stirrer-1 No.,Dropper with teat -1 No.,Cleaning Brush -1 No.,Spare latex tubing one meter -1 No.Round tube haemoglobinometer) as per Department incharge 393 Supplying of Anti - theft Sticker with the University logo as per Department incharge 394 Supplying of Middleware Application Desktop(Write and Read Tags) as per Department incharge 395 Supplying of RFID Staff Station or desktop reader (Used for tagging of books and circulation {lssue/Return) operations through RFID) as per Department incharge 396 Supplying of Integration with Software and Training of Complete RFID System as per Department incharge 397 Supplying of RFIDSecurityGates (2 pedestals-1 gate) RFID Security Gate (Single Lane) as per Department incharge 398 Supplying of Automated Book drop Box as per Department incharge 399 Supplying ofCabling. Casing. Wiring , Switches as per Department incharge 400 Supplying of Freight Transportation of Miidle ware Application Desktop,RFID STAFF Station,Integration with software training,Automated Drop box ,Cabling,Casing,Wiring,Switches as per Department incharge 401 Supplying of LAN . Switches, Necessary Cabling, Casing , Power Supply port including cables as per Department incharge 402 Supplying of Dedicated serverGHZ 16 core 1P-32GB -RP408ia -NC8SFF800WPS Serverintel Xeon -G5218 Kit for DL 380 GEN-10-HPE 32GB 2RX4 PC-4 2933YR Smart kit ,HPE DL38x Gen 10-12 Gb SAS Expande,HPE DL 380Gen 10 Box 1/2 Cage Bkpin kit ,HPE 24TB SAS 12G 10K SFF SC 512eDS HDD .HPE 800 WFS Ht Plg LHPwr Sply kit,HPE 3 Year Fiundation care 24x7 DL 380 Gen 10 Serviceas per Department incharge 403 Supplying of RS 86+_TB619RS, 3GB RAM and 48 GB ROM,4K Display Android model,3 GB RAM And 48 GB ROM,slim frame,Anti Glare Glass,3M Anti glare H7 Anti touch surface hardness lightweight for easy installation,Media suits for Annotation,Software bundled with education apps,Office suits,Great writing experience,Object recognition -First pal,/Fine pen ,Touch Points-20 points under window and 10 points under android,178 degree viewing angle IR ,Touch 15000,1 contrast ratio,4 MS Response time 50000 hours life,Reduce clutter and bring efficiency for the faculty,Remote control,15 wattX2 speaker,Android 8.0,Newline cast,Display management,Newline broadcast including installation and Trainingas per Department incharge 404 Supplying of Deep Fridgeas(2 in 1 Converti Freezer & Cooler Corrosion Resistant Cooling Coil & PPGI for inner & outer body Heavy Duty Compressor & Tropicalised Design Approximately 14% Higher Net Capacity compared to competition Sleek Design with heavy duty performance) per Department Incharge 405 Supplying of Autoclave (Horizontal,Height X Dia: 450mm x 250mm Height x Dia: 18Inch x 10Inch,Capacity: 22 Ltr,Load: 2.0 KW) as per Department Incharge 406 Supplying of Autoclave (Vertical): size- 400x600mm, Capacity- 75Ltr as per Department Incharge 407 Supplying of Hot air oven(Standard double wall fabrication. Inner chamber made of highly polished stainless steel sheet. Exterior fabricated out of thick mild steel sheet duly finished in stove enamel off-white paint or paste mat finish colour combinations.Nichrome wire heating elements -provided on three sides attain quick and uniform heating in range of 50c to 250c + 1c controlled by capillary type thermostat.Inner Chamber Size 18x18x18 inch. made of Stainless Steel) : any Standard make as per Department Incharge 408 Supplying of Bacteriological incubator(Item Weight ‎10 kg Product Dimensions-30 x 30 x 30 cm; 10 Kilograms,Item model number-12X12,Item Height-30 Centimeters Item Width-30 Centimeters) as per Department Incharge 409 Supplying of Bacteriological shaking incubator as per Department Incharge 410 Supplying of BOD incubator as per Department Incharge 411 Supplying of Laminar air flow any Standard company as per Department Incharge 412 Supplying of Micropipettes with microtips :(1.0uL-10.0uL, 10.0uL-100uL, 100uL-1000uL, 20uL-200uL): A. Prime Variable Pipette, B. Fully Autoclaveable Variable Vol. Pipetteas per Department Incharge 413 Supplying of Colorimeters with cuvettes any Standard company as per Department Incharge 414 Supplying of Western Blot apparatus, as per Department Incharge 415 Supplying of Powerpack with wiresas per Department Incharge 416 Supplying of Homogeniser as per Department Incharge 417 Supplying of PCR machine Block Formats 96x0.2ml(A),54x0.5ml(B), 96x0.2ml +77x05ml©, 384well(D) Size(WxDxH,mm)-380x270x250 as per Department Incharge 418 Supplying of UV Transilluminator/UV chamber UV source: 365nm Wave Length Viewing area: 24x14cm Anti Slip rubber foot provided for base as per Department Incharge 419 Supplying of CO2 incubator as per Department Incharge 420 Supplying of pH meter and buffers: A.pH meter B. pH buffers as per Department Incharge 421 Supplying of Water bath (any Standard company ) as per Department Incharge 422 Supplying of Fume Hood: size- 3x3x2 wooden with Granite working area as per Department Incharge 423 Supplying of Soxlet apparatus with heating mantle and distillation set up as per Department Incharge 424 Supplying of Kjeldahl Apparatus as per Department Incharge 425 Supplying of Ultrapure Water Purification System: MiliQ water as per Department Incharge 426 Supplying of Quebee Colony Counter as per Department Incharge 427 Supplying of Light Microscope (general) 25x, 45x, 100x s as per Department Incharge 428 Supplying of Bifocal microscope with illuminators as per Department Incharge 429 Supplying of Magnetic stirrer with magnetic beads(any Standard company )as per Department Incharge 430 Supplying of Magnetic stirrer with hot plate (Remi) as per Department Incharge 431 Supplying of Heating mantleas per Department Incharge 432 Supplying of Microwave oven ((20Ltr) as per Department Incharge 433 Supplying of Glass Dessicators as per Department Incharge 434 Supplying of Computer : Core i9, 7th Gen. 20 LED Monitor, 4GB DDV, 1TB HDD, DV writer HP/Dell as per Department Incharge 435 Supplying of Culture room: Tissue culture Rack fitted with 16 tubes, 8 bulbs, 4UV & Timer as per Department Incharge 436 Supplying of Electronic Analytical Balance:- Readability- 1mg(0.001g) Cap.-420gm as per Department Incharge 437 Supplying of ElectronicTop-pan Balance:-Readability- 0.1g Cap- 2kgas per Department Incharge 438 Supplying of Electroporator:- as per Department Incharge 439 Supplying of Fermenter(7.5L)(any Standard company )as per Department Incharge 440 Supplying of Fluorescence Microscopeas per Department Incharge 441 Supplying of Hot air oven universalas per Department Incharge 442 Supplying of Distillation Unit as per Department Incharge 443 Supplying of Membrane filter assembly 5000 mlas per Department Incharge 444 Supplying of Fluorimeter as per Department Incharge 445 Supplying of Homogeniser: Remi model- RQT-127 A/D High speed homogenizer, with 1/8 HP Motor, Homogenizer Working Volume [H2O] 0.1-50ml (Dispersing shaft DS-160/5) WEIGHT 0.6KG Dimension[LxWxH] 46mmx55mmx230 operating environment 0-40degre, 85% rel. humidity as per Department Incharge 446 Supplying of ELISA reader and Microtitre plates: ELISA Wavelength range 400nm-800nm Accuracy- +-1% at 1.0OD, 450nm Dimension 450x350x197mm as per Department Incharge 447 Supplying of Liminar air flow : 4x2x2 feet, stainless steel as per Department Incharge 448 Supplying of Gel Documentationd system as per Department Incharge 449 Supplying of 5 KVA Inverter with Battery Backup. Microtek inverter, online UPS 65Mah Battery (16 units) -Exide as per Department Incharge 450 Supplying of 12V/26AH- Batteryas per Department Incharge 451 Supplying of Headphone with built in microphone (Brand) as per Department Incharge 452 Supplying of Furniture:- Computer Table & Chairs & Table- Chair for lab. Instructor and student (50 students per batch) as per Department Incharge 453 Supplying of Network:- LAN, Switches, Cabling, Casing Power Supply Port including Cables as per Department Incharge 454 Supplying of 5.5 KVA Inverter with Battery Backup. Microtek inverter, online UPS 65Mah Battery (16 units) -Exide as per Department Incharge 455 Supplying of RS86+ TT8619RS 3 GB RAM, 48 GB ROM 4K Display, Android Model Slim Frame, Anti-Glare Glass, 3M Anti-Glare, H7 touch surface hardness, Light weight for easy installation. Media Suits for Annotation Software. Bundle with Education Apps. Office Suits. Great Writing Experience. Object Recognition- Fist/Palm/Fine Pen, Touch Points-20 points under Android. 178 Degree viewing Angle, IR Touch. 15000:1 contrast ratio, 4MS Response Time, 50000 Hours life. Reduce cluster and bring efficiency for the faculty. Remote control, 15 watts x 2 speaker. Android 8.0, Newline Cast, Display Managemen, Newline Broadcast Including Installation and Training. as per Department Incharge 456 Supplying ofpH meter(Digital) :- pH range: 0-14, Temperature Range: 0.0 to 100 C (Manual Compensation) as per Department Incharge 457 Supplying ofNoise Level meter:- Auto/Manual ranging from 30 to 130dB in 6 ranges as per Department Incharge 458 Supplying ofWater analysis Kit:- They include; alkalinity, chloride, hardness, iron, and sulphate as per Department Incharge 459 Supplying ofHigh volume sampler:- 1)PM-2.5- Designed to meet International Standards for High volume air Sampling of PM2.5 particulates. 2)PM-10-U.S EPA FRM Designed for the determination of suspended of PM-10 particulates concentrations. (RFPS-1287-063) 3)TSP- Designed to meet U.S EPA reference method for determination of total suspended particulates(TSP) concentration as perDepartment Incharge 460 Supplying ofSoil testing kit (mrinda parikshan kit) : Use for micro and macro nutrients as per Department Incharge 461 Supplying ofSeive plate with shaker : 5mm,1mm,2mm) as per Department Incharge 462 Supplying ofUV/Visible spectrophotometer:- Spectral bandwidth 1 nm (190 to1100nm , Lamp Type 20-W halogen lamp and deuterium lamp as per Department Incharge 463 Supplying ofAutoclave : 10-15 litre Steam Sterilizer as per Department Incharge 464 Supplying ofLaminar hood (Horizantal) : Horizontal air flow cabinet, filter air blow across the work zone in horizontal direction. This constant flow of air provides material and product protection as per Department Incharge 465 Supplying ofHot plate(pic):-Temperature range: 350 C as per Department Incharge 466 Supplying ofShakeer incubator Compact Bench top shaker with temperature control range from Ambient +50C to 600C. Tray dimension : 420x420 , Speed 50-350 rpm with accuracy of +/- 2rpm as per Department Incharge 467 Supplying ofMuffle Furnaces (15x125x250)cm: Temperature upto 35C to 1400C as per Department Incharge 468 Supplying of Analytical Balances:Capacity 220gram as per Department Incharge 469 Supplying ofDigester : 1) vessel size : Dia 39 mm (Aprox.); Volume 160ml 2)Temperature : upto 200degC as per Department Incharge 470 Supplying ofDouble distilled water plant: Model- Vertical:- Distlled Water Output Capacity-2.5 Litres/Hours, Distillate water quality as per Department Incharge 471 Supplying ofOven:- Dry ovens- 30 to 1000 litre capacity. as per Department Incharge 472 Supplying of B.O.D Incubator: Volume 68 Litre as per Department Incharge 473 Supplying ofMagnus Microscope:- Magnification 4x,10x,40x, and 100x as per Department Incharge 474 Supplying ofDesiccators:- Contain: Silica Gel dimension;12x12 in (30.5x30.5 cm),Material Glass as per Department Incharge 475 Supplying ofRichter scale hardness tester Portable Rockwell/brinell vickers Hardness Testing Instrument Mold metal hardness meter display:-parameter- HRC Display Type, Digital Model Name/Number- ATedigiHR, Accuracy- 0.1 HRC Dimensions of Machine base (approx.) 150x425 mm as per Department Incharge 476 Supplying ofProctor Penetrometer: Proctor Penetrometer- Complete with set of needle points Weight, 2 kg as per Department Incharge 477 Supplying ofGas Chromatography Retention time repeatability-< 0.008% or 0.0008 min Area rpeatability -<1% RSD, using 2ng tetradecane as per Department Incharge 478 Supplying of Atomic Absorption Spectrometry(AAS):- aa-7000 SERIES OF Atomic Absorption Spectrophotometers features high- sensitivity analysis as per Department Incharge 479 Supplying ofWavelength range; 400 to710nm Wavelength selection: 8 in-built gelatin filters: 430,470,490,520,540,580,600 and 710 nm Measurement ranges; 0-100%T, 0-1.50Abs, 0.1 to 1000 Concentration. Resolution: 1%T, 0.01Abs, 0.1 to 1 Concentration as per Department Incharge 480 Supplying of Laptops(of Specification:Processor Corei5,RAM:4GB,Hard drive:500GB ,Screen size:12 inch):as per Department Incharge 481 Supplying of Desktops: i7 3rd Gen, 1TB HDD, 4GB RAM, Windos 10, MS office, Graphics card as per Department Incharge 482 Supplying of Xerox Machine(Product Specification:Functions Multi-Function:Supported Paper Size-A3,Supported OS-all,Color Output-Black & White,Number Of Trays-4,Item Color-white and blue Print Speed-up to 35 ppm,Weight 129 kg,Print Technology-Laser Warm-Up Time, As fast as 11 seconds (black and white) Duty Cycle-WorkCentre 5335: Up to 150,000 pages / month Resolution-200 x 1200 dpi) as per Department Incharge 483 Supplying of Air Conditioning:-1.5 Ton heavy duty AC (mimimum 3 Star rating) as per Department Incharge 484 Supplying of Luminous Cruze 3.5KVA Inverter with RC 18000 Battery (4 Batteries) as per Department Incharge 485 Supplying of Projector(Special Feature-portable,Connectivity Technology,Bluetooth, Wi-Fi, USB, HDMI,Display resolution 1920 x 1080,Display Type-LED) as per Department Incharge 486 Supplying of Godrej Lecture Hall Furniture as per Department Incharge 487 Supplying of Electronic Podium(Speaker type-Tweeter,Auxillary,wireless,floor standing) as per Department Incharge 488 Supplying of Smart board (Screen size-11 inches,Connecting technology-Wifi,Multimedia)as per Department Incharge 489 Supplying of Black board( Melamine Writing Surface (Chalk), Paper Honeycomb Core, 6063-T6 Alloy Aluminium Frame & Virgin ABS CornersMelamine Writing Surface (Chalk), Paper Honeycomb Core, 6063-T6 Alloy Aluminium Frame & Virgin ABS Corners) as per Department Incharge 490 Supplying of Glassware rack as per Department Incharge 491 Supplying of installation of Air conditioner,Luminous Cruze,Projector,Lecture Hall Furniture,Electronic podium,Smart board and black board as per Department Incharge 492 Supplying of Inductively coupled Plasma - Optical Emission Spectrometer with CID detector technology for multi-element analysis of geological petrogical etc. samples in ppb level as per Department Incharge 493 Supplying of Suppressed ion analysis system for anion and cation analysis in water, wastewater, environmental samples and also upgradable to combustion for determination of corrosive halogens and sulfur in Petrochemicals, gaseous samples, solid samples, and complex samples as per Department Incharge 494 Supplying of CHNS/O for the analysis of Carbon, Hydrogen, Nitrogen, Sulfur and Carbon in organic matrices, soil, feed , plant samples, petroleum products, Coal, Coke, Biomass & Liquid Fuels as per Department Incharge 495 Supplying of Gas Analyzers for hydrocarbon and permanent gas analysis as per Department Incharge 496 Supplying of Benchotop XRD as per Department Incharge 497 Supplying of XRF Spectrometer as per Department Incharge 498 Supplying of Refrigereted Centifuge MakE-REMI, Model-C24 PLUS :- Max. Speed:20000, Max. RCF:3757, Max. Lowest Temp.:8, Noise:60db. Essential accessories Required: 01. Withangle Heads (with polypropulene tubes) Model-R-248M24x1.5ml 2)Voltage stabilizer:-03KW Servocontrolled Voltage Stabilizer, input 170volts to 260volts, output 220 to 240volts as per Department Incharge 499 Supplying of pH Meter compatible poer bank Make: REMI :- With eletrode as per Department Incharge 500 Supplying of Bench top Centrifuge Make: Tarson, : - SPINWIN MC-001 6 places Rotor for 1.5 ml tubeas per Department Incharge 501 Supplying of Deep Fridge: It is used to store chemicals and preserve samples at very low sub-zero tempertures or below as per Department Incharge 502 Supplying of Autoclave(Vertical) : size- 400x600mm capacity- 75Ltr as per Department Incharge 503 Supplying of Hot air oven : Sterilization as per Department Incharge 504 Supplying of Incubator Shaker: Growth and enumeration of microbes(Broth Cultures) as per Department Incharge 505 Supplying of Horizontal Laminar air flow:- Sterile environment size 4x2as per Department Incharge 506 Supplying of Ultrapure Water Purification System: MiliQ Water : for distil water as per Department Incharge 507 Supplying of Micropipets (Ependroff): 0.1uL-2.5uL, 0.5uL-10uL, 10.0uL-100uL, 100uL-1000uL each oo these 1pcs as per Department Incharge 508 Supplying of Light Microscope (general)10X, 20X, 45X, 100X, : Visualize microorganisms as per Department Incharge 509 Supplying of Bifocalcal Microscope with illuminators, Camera Attachment and comput: Visuallize microorganisms and micrography as per Department Incharge 510 Supplying of Magnetic stir with Hotplate and magnetic bead as per Department Incharge 511 Supplying of Heatingmant; for heatinground bottomed flask/distillation flask as per Department Incharge 512 Supplying of Microwave oven: To heat liquids instead of flaming. 20Ltrs as per Department Incharge 513 Supplying of kydroPro 100 handeld multiparameter water quality analiser: Turbedityas per Department Incharge 514 Supplying of Petrological Microscope: Study of Optical minrology as per Department Incharge 515 Supplying of Ore petrological microscope: Study of ore petrology as per Department Incharge 516 Supplying of Miscellaneous instruments as per Department Incharge 517 Supplying of glassware as per Department Incharge 518 Supplying of chemical as per Department Incharge 519 Supplying of Arc GIS(Latest) as per Department Incharge 520 Supplying of GCD Toolkits as per Department Incharge 521 Supplying of SURPAC Software as per Department Incharge 522 Supplying of Intergraph Edu Kit [GIS+RS] Version 2020 or latest(Software content as per list), 5 users for Erdas imagine Professional and 5 users for Geomedia professional Software as per Department Incharge 523 Supplying of Interactive Flat Panel as per Department Incharge 524 Supplying of 2 Virtual Class Room including capture, recording and streaming online, 1 Servers one per 05 classrooms per Department Incharge 525 Supplying of N-computing for smart classrooms including servers and clients as per Department Incharge 526 Supplying of Tagging of documents(books/hard-bound journals/CDs/technical films etc)in RFID Technology as per Department Incharge 527 Supplying of Sofwares, Server Machines, Air-Conditioning Systems,Xerox Machines, Lamination Machines, Binding Machines, Furniture/Furnishing, Computers, Printers etc as per Department Incharge 528 Supplying of Digital Podium, PTGN 500, Window & 1 LCD, Elecronic Lectern, on site OEM. Warranty 3years, 3GB RAM,4GB ROM as per Department Incharge 529 Supplying of Air Conditioning:-1.8 Ton heavy duty AC (mimimum 3 Star rating) as per Department Incharge 530 Supplying of Black/ White,Printer:- scan-copy all in printer- Branded as per Department Incharge 531 Supplying of CCTV set for floor: 55 LRD display for CCTV. CCTV Camera-1 P based CCTV camera 2TB space with NVR with necessary accessories as per Department Incharge 532 Supplying of 5KVA Inverter online UPS with battery backup 100Mah battery(8 units) as per Department Incharge 533 Supplying of Electrophoresis Apparatus as per Department Incharge 534 Supplying of Bacteriological Incubator as per Department Incharge 535 Supplying of Autoclave as per Department Incharge 536 Supplying of Centrifuge as per Department Incharge 537 Supplying of Rotar Head as per Department Incharge 538 Supplying of Rotar Head 25 as per Department Incharge 539 Supplying of Gel documentation system as per Department Incharge 540 Supplying of Spectrophotometers as per Department Incharge 541 Supplying of compoud Microscope as per Department Incharge 542 Supplying of Trinocular Microscope with camera as per Department Incharge 543 Supplying of Semi-Automated Microtonne as per Department Incharge 544 Supplying of DNA Sequencer as per Department Incharge 545 Supplying of Spectrophotometer as per Department Incharge 546 Supplying of Laminar air flow chamber as per Department Incharge 547 Supplying of Tissue culture rack as per Department Incharge 548 Supplying of PCR Apparatus as per Department Incharge 549 Supplying of Liquid nitrogen cylinder as per Department Incharge 550 Supplying of TLC apparatus kit as per Department Incharge 551 Supplying of TLC Visualizer/documentation as per Department Incharge 552 Supplying of HPLC System as per Department Incharge 553 Supplying of Scientific vortex mixer as per Department Incharge 554 Supplying of Soil Thermometer as per Department Incharge 555 Supplying of Scientific Digital Balance as per Department Incharge 556 Supplying Equipments for workshop,Seminar & Excrusion as per Department Incharge 557 Supplying Equipments for Non-Recurring(Research Equipment) as per Department Incharge 558 Supplying Equipments for Recurring(Chemical & Glassware) as per Department Incharge 559 Supplying of Furniture Bookshelves, Study Tables and Chairs for Readers as per Department Incharge 560 Supplying of Desktop i5 Processor, 7th Generations, 500GB HDD, 4GB RAM, 23.8 inch, LED backlit Monitor Full HD IPS Panel (Brand: HP/DELL) as per Department Incharge 561 Supplying of Headphone with built in microphoneas per Department Incharge 562 Supplying of Printer with scanner (Laser,Colour/B/W)as per Department Incharge 563 Supplying of Scanner(USB,25.2D x 36.8W x 4.3H Centimeters,Slide) as per Department Incharge 564 Supplying of Xerox Machine:- (,Platen cover & Toner, Resolution (DPI):1200 X 1200dpi, Duty Cycle:1.3 Sec) as per Department Incharge 565 Supplying of Lamination Machine(Paper size-A4,A3,FS,max laminating width-500mm,Laminating speed-1200mm)as per Department Incharge 566 Supplying of CCTV Camera(Full HD Picture,AI Powered Motion Detection,Infrared Night Vision; 360° Panorama,Talk Back Feature (2-Way Audio)Material Type: Plastic; Included Components: Camera, Power Adapter, Charging Cable, Wall Mounting Kit, User Manual; Specific Uses For Product: Surveillance) as per Department Incharge 567 Supplying of 75 inch diagonal length with 3 GB RAM, 48 GB ROM 4K Display, Slim Frame, Anti-Glare Glass, 3M Anti-Glare, H7 touch surface hardness, Light weight for easy installation. Media Suits for Annotation Software. Bundle with Education Apps. Office Suits. Great Writing Experience. Object Recognition- Fist/Palm/Fine Pen, Touch Points-20 points under Android. 178 Degree viewing Angle, IR Touch. 15000:1 contrast ratio, 4MS Response Time, 50000 Hours life. Reduce cluster and bring efficiency for the faculty. Remote control, 15 watts x 2 speaker. Android 8.0 Newline Cast Display Management including wall mount and installation. as per Department Incharge 568 Supplying of RS75+ TT7519RS RS 75+ comes with 75 inch diagonal length with 3 GB RAM, 48 GB ROM 4K Display, Android Model Slim Frame, Anti-Glare Glass, 3M Anti-Glare, H7 touch surface hardness, Light weight for easy installation. Media Suits for Annotation Software. Bundle with Education Apps. Office Suits. Great Writing Experience. Object Recognition- Fist/Palm/Fine Pen, Touch Points-20 points under Android. 178 Degree viewing Angle, IR Touch. 15000:1 contrast ratio, 4MS Response Time, 50000 Hours life. Reduce cluster and bring efficiency for the faculty. Remote control, 15 watts x 2 speaker. Android 8.0 Newline Cast Display Management. as per Department Incharge 569 Supplying of Wall Mount Kit(Material: SS,Max loading capacity-60 to 100kg) as per Department Incharge 570 Supplying of Live streaming software Software Software for Live Streaming or Live telecast as per Department Incharge 571 Supplying of 75 inch diagonal length with 3 GB RAM, 48 GB ROM 4K Display, Slim Frame, Anti-Glare Glass, 3M Anti-Glare, H7 touch surface hardness, Light weight for easy installation. Media Suits for Annotation Software. Bundle with Education Apps. Office Suits. Great Writing Experience. Object Recognition- Fist/Palm/Fine Pen, Touch Points-20 points under Android. 178 Degree viewing Angle, IR Touch. 15000:1 contrast ratio, 4MS Response Time, 50000 Hours life. Reduce cluster and bring efficiency for the faculty. Remote control, 15 watts x 2 speaker. Android 8.0 Newline Cast Display Management including wall mount and installation. as per Department Incharge 572 Supplying of Frieght Transportation of 4K Display,Wall mount kit,Live Streaming software as per Department Incharge 573 Supplying of cctv solutions for Department with 20 cameras(Image Sensor Type-CMOS,Image Sensor Size-0.357 inch,Camera Image Sensing capacity (Picture Mode)-2MP,Resolution-Full HD (1920 x 1080 Pixel)-Day/Night Capable-Yes,IR illumination Range(mtr) 200 Type of Camera HousingDOME CAMERA,IP Camera Yes) as per Department Incharge 574 Supplying of installation and commisioning of CCTV and other computer equipment as per Department Incharge 575 Supplying of 55 Tv for seeing all cctv in HOD room as per Department Incharge 576 Supplying of8 PORT EPBX as per Department Incharge 577 Supplying ofTELEPHONE as per Department Incharge 578 Supplying ofWIRE as per Department Incharge 579 Supplying of CRON BOX as per Department Incharge 580 Supplying ofSWITCHES FOR PORTS as per Department Incharge 581 Supplying of Workststion Table, Chairs, Desktop, UPS as per Department Incharge 582 Supplying of LAN, Switches, Necessary Cabling, Casing Power Supply Port including Cables as per Department Incharge 583 Supplying of Refrigerator(Storage & Interior Description : | Cooling Type ; Frost Free | Display Type ; Thermostat | Shelf Material ; Toughened Glass | Compressor Type ; Reciprocatory)as per Department Incharge 584 Supplying of Microwave(Special Features: Quartz Heater - Concealed Heating. Safer Cooking, Stainless Steel Cavity - More Hygienic. More Durable, Child Lock - Ensures complete safety especially for homes with young children, Interior light)as per Department Incharge 585 Supplying of Washing Machine( Fully automatic 6 kg) as per Department Incharge 586 Supplying of Sewing Machine(Motorised)as per Department Incharge 587 Supplying of Weighting Machineas per Department Incharge 588 Supplying of Blood Pressure Monitor as per Department Incharge 589 Supplying of Oximeter as per Department Incharge 590 Supplying of Gluco Meter as per Department Incharge 591 Supplying of Test Tube & Breakers as per Department Incharge 592 Supplying of RO Water Purifier as per Department Incharge 593 Supplying of Microscope(Student) as per Department Incharge 594 Supplying of Crockery Set as per Department Incharge 595 Supplying of Cocking Utensils set as per Department Incharge 596 Supplying of Cutlery Set as per Department Incharge 597 Supplying of Sofa Set + Centre Table as per Department Incharge 598 Supplying of A.C (Split 2 Ton,3 Star,Twin invertor HD Compressor)as per Department Incharge 599 Supplying of Stabilizer(Automatic Voltage Stabilizer,37.4 x 27.1 x 19.8 Centimeters,5 kg 700 g)as per Department Incharge 600 Supplying of Inveter with battery(Capacity -100AH,Battery Type-Tubular Battery,Warranty-1 years,Protection From Short Circuit, Over Temperature, Battery Deep -Discharge,Backup Time 8 Hrs Backup- 1 FAN ,28 Light , 8 Hrs Backup - 1FAN ,1 Light Battery Condition-New) as per Department Incharge 601 Supplying of Desktop Computer with UPS and Computer Tableas per Department Incharge 602 Supplying of Original operating system software window 10 with Antivirus as per Department Incharge 603 Supplying of Printer with scanner (inkjet,Colour/B/W)as per Department Incharge 604 Supplying of Dining Table Set as per Department Incharge 605 Supplying of Camera as per Department Incharge 606 Supplying of Mixer Grinder as per Department Incharge 607 Supplying of Iron as per Department Incharge 608 Supplying of Wall Clockas per Department Incharge 609 Supplying of Whole tailoring Equipments (Local) as per Department Incharge 610 Supplying of Knitting Equipments(Local) as per Department Incharge 611 Supplying of Flower Arrangement Equipments) (local) as per Department Incharge 612 Supplying of Aluminium Set as per Department Incharge 613 Supplying of Plastic Tub as per Department Incharge 614 Supplying of Dustbin(Big) as per Department Incharge 615 Supplying of Basket &Mug as per Department Incharge 616 Supplying of White Table Cloth(Big size)as per Department Incharge 617 Supplying of Wash Basin(Local)as per Department Incharge 618 Supplying of Gas Stove +Cylinderas per Department Incharge 619 Supplying of Curtains(Local) as per Department Incharge 620 Supplying of Floor Mats (Local) as per Department Incharge 621 Supplying of Tube Lightas per Department Incharge 622 Supplying of Fan as per Department Incharge 623 Supplying of Led Projector(New Edition)as per Department Incharge 624 Supplying of Smart Board(specification:white,power consumption<150w ,usage-school,Effective touch-65x46) as per Department Incharge 625 Supplying of Decorative Items(Local) as per Department Incharge 626 Supplying of Xerox Machine (Specification-Functions:Print | Scan | Copy,Technology -Laser,Print speed-upto 60 pages/min,Paper size-A4,Connectivity-Wireless(Wi-Fi),Color output-Color | B&W, Print Volume(per month) -above 15000 ppm,Features-Two-sided printing,Weight-25kg,Dimension-451 x 460 x 360mm,Scanner type Flatbed scanner multi as per Department Incharge 627 Supplying of Ceiling Fanas per Department Incharge 628 Supplying of Exhaust Fan as per Department Incharge 629 Supplying of Pedestal Fan as per Department Incharge 630 Supplying of Inveter with battery(Capacity -200AH,Battery Type-Tubular Battery,Warranty-3 years,Protection From Short Circuit, Over Temperature, Battery Deep -Discharge,Backup Time 14 Hrs Backup- 4 FAN , 8 Light , 14 Hrs Backup - 1FAN ,1 Light Battery Condition-New) as per Department Incharge 631 Supplying of Wooden Stool(Local) as per Department Incharge 632 Supplying of Wash Basin (Local) as per Department Incharge 633 Supplying of Register (Local) as per Department Incharge 634 Supplying of Stabilizer for ACas per Department Incharge 635 Supplying of Tubelightas per Department Incharge 636 Supplying of Dustbin (Local) as per Department Incharge 637 Supplying of Curtains (Window and Door) (Local)as per Department Incharge 638 Supplying of Door Mat(Local) as per Department Incharge 639 Supplying of Broadband(Wifi)as per Department Incharge 640 Supplying of Furniture Bookshelves, Study Tables and Chairs for attendant and students (30 students at a time) as per Department Incharge 641 Supplying of Wireless mic as per Department Incharge 642 Supplying of Weight Box(100g std.) :- Containing 10 cynlinders of the same size and shape but different in weight as per Department Incharge 643 Supplying of Weight Box(50g std.) :- Containing 10 cynlinders of the same size and shape but different in weight as per Department Incharge 644 Supplying of Kymograph :-with smoked paper, smoked Drum, Time marker as per Department Incharge 645 Supplying of Memory Drum :- Electrical operated as per Department Incharge 646 Supplying of Memory Drum :- Hand operated as per Department Incharge 647 Supplying of Metronome :- Mechanical as per Department Incharge 648 Supplying of Porteuz Maze Test as per Department Incharge 649 Supplying of Techisto-scope :- Fall Drop type as per Department Incharge 650 Supplying of Techisto-scope :-Electronic as per Department Incharge 651 Supplying of Verniers chronoscope :- Pendulum Type as per Department Incharge 652 Supplying of Ergograph/Smoke drum /smoke paper varshing tray and varnish :- Hand grip model as per Department Incharge 653 Supplying of Weight 6Kg as per Department Incharge 654 Supplying of Multiplication sheets(100sheet) as per Department Incharge 655 Supplying of Screen:- Wooden as per Department Incharge 656 Supplying of Ravens Progressive Matrices as per Department Incharge 657 Supplying of Weschlers Intelligence scale (Adult) as per Department Incharge 658 Supplying of Cattles 16 PF Questionnaire as per Department Incharge 659 Supplying of Jungs Word Association Test as per Department Incharge 660 Supplying of Thematics Apperception Test as per Department Incharge 661 Supplying of Zeigarnik Effect Test as per Department Incharge 662 Supplying of The Occupational Stress Index(OSI) Scale by A.K Shrivastawa and A.P. Singh as per Department Incharge 663 Supplying of Rorschach Test as per Department Incharge 664 Supplying of Coping Strategies Test by A.K. Shrivastava as per Department Incharge 665 Supplying of Job Satisfaction scale(JSS) by Amar Singh and T.R. Sharma as per Department Incharge 666 Supplying of Job Involvement Scale by A.K. Singh and R. Kapoor as per Department Incharge. 667 Supplying ofOrganizational Climate Scale by Somnath Chatopadhya and K.G. Agarwal as per Department Incharge 668 Supplying of Managerial Aptitude Scale(MAS) by Santosh Dhar, Upinder Dhar and Priyanka Sharma as per Department Incharge 669 Supplying of Employees Motivational Scale by A.K. Shrivastava as per Department Incharge 670 Supplying of Employees Mental Health Inventory (EMHI) by Jagdish as per Department Incharge 671 Supplying of Beck Depression Inventory by Arron Beck as per Department Incharge 672 Supplying of Aggration Scale (AS) by G.P. Mathur and Rajkumar Bhatnagar as per Department Incharge 673 Supplying of Ego Strength Scale by Q. Hassan as per Department Incharge 674 Supplying of Bells Adjustment Iventory by S.M. Mohsin and Shamshad as per Department Incharge 675 Supplying of Marital Adjustment Questionnaire by P. Kumar and kanchan Rohtagi as per Department Incharge 676 Supplying of Sacks Sentence Completion Test as per Department Incharge 677 Supplying of PGI Health Questionnaire N-1 (PGIHQN) by S.K. Verma, N.N. Wig and D. Prasad as per Department Incharge 678 Supplying of Rotters Locus of Control Scal by Anand Kumar and S.N Srivastava as per Department Incharge 679 Supplying of Self Concept Inventory by O.N Srivastava as per Department Incharge 680 Supplying of PGI Social Support Scale by S.K. Verma, P. Kulhara and Ritu Nehraas per Department Incharge 681 Supplying of Emotiobnal Maturity Scale(EMS) by R.R. Trtipathi as per Department Incharge 682 Supplying of Life satisfaction Scale(LSS) by Q.G. Alam and R. Srivastava as per Department Incharge 683 Supplying of PGI Quality of Life Scale by S.K Verma and A.C. Moudgil as per Department Incharge 684 Supplying of Environmental Awareness Scale (EAS) by Haseen Taj as per Department Incharge 685 Supplying of Jatota Test of Group Mental ability as per Department Incharge 686 Supplying of Weinsteins Noise Sensitivy Scale (WNSS)(Shore Samvedi Mapak) by P. Bhatia, S. Mohar and I.S Mohar as per Department Incharge 687 Supplying of State Traight Anxiety Test (STAT) as per Department Incharge 688 Supplying of Xerox Machines (Digital)(Product Specification:Copy | Print | Scan | Fax,Number Of Trays-2,Item Color-Black,Duty Cycle-20000,Print Technology-LaserPrint Speed-25 Paper Per Minute ) as per Department Incharge 689 Supplying of Binding Machine (Product Specification:Capacity-12-15 Sheets,Binding Style-Manual ,Max Binding Thickness<20 mm Max Binding Sheet Width 200-300 mm,Automatic Grade-Semi-Automatic,Weight-5.8Kgs Approx.,Dimension-375x230x150mm Approx.Automation Grade,Hole Size-3x8mm,Paper Size-A4 /Letter /A5 etc,Packaging Weight-375 mm,Handle Type-metal,Packaging Size-375x230x150mm Approx.Adjustable Margin-2.5/4.5/6.5mm,Usage/Application-Comb Binding Method Of Operation-Manual,No Of Punch Holes-21 holes Number Of Punch Slots-21 holes,Size-A4,Number Of Punch Holes-21 holes,Machine Dimension-375x230x150mm Approx.Is It Padded)as per Department Incharge 690 Supplying of Printers(Ink End Sensor-yes,paper storage capacity-100 sheets Paper Input, 50 sheets Paper Output-printing technology ink tank,connecter type-Wi-Fi, USB,special feature-Cost per print - 9 paise (Black & White), 33 paise (Colour) as per Department Incharge 691 Supplying of Furnishing (Book shelves:Study table and chair)as per Department Incharge 692 Supplying of Book Case(for Psychological Tests) as per Department Incharge 693 Supplying of Open Racks as per Department Incharge 694 Supplying of Inveter with battery(Capacity -150AH,Battery Type-Tubular Battery,Warranty-3 years,Protection From Short Circuit, Over Temperature, Battery Deep -Discharge,Backup Time 8 Hrs Backup- 2 FAN , 2 Light , 12 Hrs Backup - 1FAN ,1 Light Battery Condition-New) as per Department Incharge 695 Supplying of Inverter with Battery(Capacity-150,Battery Type-Tubular Battery,Warranty-3 years,Protection From Short Circuit Backup Time-5hrs,Battery Condition-New)as per Department Incharge 696 Supplying of Desktop(Product Specification:Hard Drive Capacity-320GB,Operating System-Window,Screen Size-17 inch Processor-i5,Display Type LCD Processor) as per Department Incharge 697 Supplying of Tally sofware (Multi User) as per Department Incharge 698 Supplying of Barcode Machine(Product Specification:Type-Thermal Printers,Max Printing Size-10 IPS,Resolution (dpi)-203dpi Model/Type-Citizen CLS-700,Automatic Grade-Fully Automatic Print Line-1~3 Lines) as per Department Incharge 699 Supplying of Server Machines(Product Specification:Memory-1x16 GB RAM/ Open Bay- 2.5 Hot Swap SAS/ SATA,Power Supply 220 V,Networking Type-LAN,Number Of Ports/Channels-8 USB Port-Yes Processor Speed Intel Xeon Silver 4114 (Deca Core) 2.2GHz Power Consumption 750 W) as per Department Incharge 700 Supplying of LAN connection between 7 computers as per Department Incharge 701 Supplying of Xerox Machine (Specification-Functions:Print | Scan | Copy,Technology -Laser,Print speed-upto 30 pages/min,Paper size-A4,Connectivity-Wireless(Wi-Fi),Color output-Color | B&W, Print Volume(per month) -above 10000 ppm,Features-Two-sided printing,Weight-16.8kg,Dimension-451 x 460 x 360mm,Scanner type Flatbed scannercannon image Class MF641CW multi as per Department Incharge 702 Supplying of Lamination Machine(Paper size-A4,A3,FS,max laminating width-330mm,Laminating speed-600mm)as per Department Incharge 703 Supplying of Binding Machine (Punches-43 holes,Hole distance-43 holes in A 11 SHEET,Binding sizes:Max 11) as per Department Incharge 704 Supplying of Computers (Processor -AMD Ryzen 3,RAM-8GB,HDD-512 GB,screen size-19.5 inches,Operating system:Windows 11 )as per Department Incharge 705 Supplying of Office Computer (Processor:i5 10th,HDD:1 TB,RAM-4 GB,GT730 4GB Graphics) as per Department Incharge 706 Supplying oflaser printer(Product Specification:Color Output-Black & White,Function-Print | Scan | Copy,Max. Print Speed (Black)-18 ppm Max. Print Speed (Color)-17 ppm,Connectivity-Ethernet,Paper Size-A4,Print Volume-Up to 500 pages/month) as per Department Incharge 707 Supplying of Smart class Board(Power consumption:220-300V,size/Dimension-65,Input type-finger Touch) per Department Incharge 708 Supplying of Double battery(capacity-250Ah,Over current protection) Inverter(Back up time-5 hrs) as per Department Incharge 709 Supplying of Desktop Computers :- HP 23.8-inch FHD All in One Desktop with Alexa Built-in(10th Gen Intel Core i3- 1005G1/8GB/512 GB SSD/Windows 10/MS Office 2019/Natural Silver), 24-dp0816in as per Department Incharge 710 Supplying of Printer, ScannerMulti-Function Direct Wireless Network Laser Printer (Print, copy, scan, Black) as per Department Incharge 711 Supplying of Networking (LAN, leased lines, wi-fi, switches etc.) TP-Link Archer C6 Gigabit MU-MIMO Wireless Router, Dual Band 1200Mbps Wi-Fi Speed, 5 Gigabit Ports, 4 External Antennas and 1 Internal Antenna WiFi Coverage with Access as per Department Incharge 712 Supplying of Back up support(UPS, Generator, Transformer):-600VA UPS for Desktop/PC/Computers(not for Routers) with Automatic Voltage Regulation as per Department Incharge 713 Supplying of Xerox Machine:- (IR2004 With Duplex, Platen cover & Toner, Resolution (DPI):600 X 600dpi, Duty Cycle:4.3 Sec) as per Department Incharge 714 Supplying of IBM SPSS(Statistics Package Latest Version) as per Department Incharge 715 Supplying of Nvovo(Package) as per Department Incharge 716 Supplying of LCD Projector:- 1)Project movies,images or data from your devices,most effective in dark settings 2)Projector, Lens Cover/Stand, Carrying Pounch, USB Cable 3) Connect via Wi-Fi to Android smartphones and tables or connect HDMI to iPhone or iPad as per Department Incharge 717 Supplying of Projector Screen:- 1)10 Feet x 6 Feet, 133 Dia, 16:9 Format, UHD-3D-4K 2)Comes with FULL HD 1080P 3D and 4K Viewing Technology, Anti UV coating as per Department Incharge 718 Supplying of DTH connection:- 1)HD Set Top Box 2)Recording facility as per Department Incharge 719 Supplying of Television Set:- 1) Smart LED TV-42 inches 2)4K UHD (Resolution:3840x2160) 3)Connectivity-Input:3*HDMI,3*USB 4)Audio:20W output 5) 4K HDR provides exceptional clarity 6)Smartphone connectivity : Photo sharing plus, screen mirroring as per Department Incharge 720 Supplying of as per Desktop:- Intel i7, 8th Gen, 4GB N-Vidia Geforce Graphics card, 16 GB RAM, Monitor, CPU, Mouse, key board partment Incharge 721 Supplying of Multifunction Laser Printer,Scanner, and Copier :- Functionality: Print, Scan,Copy Print Technology : Monochrome Laser Connectivity: Hi-speed USB, Compatible with USB 2.0 Specifications4as per Department Incharge 722 Supplying of Speaker 7.1 surround stereo(Power -100W,Play tme-11 hours,Voice Range-9m) as per Department Incharge 723 Supplying of Digital SLR Camera: 1)EOS full HD movie mode with movie service 2)18 megapixel CMOS)APS-(sensor 3)14-bit A/D conversion 4)ISO 100-12800)EXPANDABLE TO h:25600(5)Dual Lens camera 55-250mm IS II lens 6) Camera battery charger and bag 7)Wide strap USB cable, software CD. as per Department Incharge 724 Supplying of 24.2MP DigitalSLR Camera:- 1)100% Viewfinder Coverage 2)CMOS sensor with impressive high-resolution result 3)Camera battery, charger, and bag 4)Wide strap USB cable, software CD, manual as per Department Incharge 725 Supplying of Quark express as per Department Incharge 726 Supplying of Adobe Suite(CS6 Master Collection) as per Department Incharge 727 Supplying of Cool Edit Pro as per Department Incharge 728 Supplying of Turnitin as per Department Incharge 729 Supplying of Sound Forge as per Department Incharge 730 Supplying of 18-55mm normal lens as per Department Incharge 731 Supplying of 55-250mm Zoom lens as per Department Incharge 732 Supplying of 18-135mm lens as per Department Incharge 733 Supplying of 35mm prime lens as per Department Incharge 734 Supplying of 80mm macro lensas per Department Incharge 735 Supplying of Tripods as per Department Incharge 736 Supplying of DSLR:- 1)Powered by NP-F570 InfoLithium rechargeble battery pack 2)Records to MiniDV tape stock 3)16:9 widescreen recording 4)3CCD video camera 5)12x optical zoom lens 6)Records to MiniDV tape stock as per Department Incharge 737 Supplying of:- 1)3CCD video camera 2) Crystal Engine 3)Shoulder -Type Design 3)One Touch Navigation 4)Manual Focus Ring 5) 0 lux colour light view 6)10x optical zoom 6)500x digital zoom 7)Super image stabilizer 8) DV IN/OUT Terminal 8)5-mode programme AE: sports, portrait, low light, spot light, and surf &snow 9)SP/I.P recording 10)Back light compensation 11) Cinema mode )16:9 aspect ratio( 12)Infra-red remote controller as per Department Incharge 738 Supplying of Tripods:- 1)3-way head with adjustable pan 2)Steady rubberized legs 3)Multipurpose head with quick release 4)Multipupose head for DV cameras 5)Made from High Grade Aliminium Alloy 6)Quik flip leg locks 7)Fluid pan&tilt movement 8)Quik release plate& Bubble Level as per Department Incharge 739 Supplying of i-Mac(Product Specification,Storage Capacity-256 GB Display-24 inch,Memory Size-256gb ssd,assembled Product Dimensions L X W X H,461 mm x 547 mm x 130 mm, 4.48 kg Color-Silver & Blue,Graphics-8_core GPU,Video Support And Camera 4.5K,Bluetooth-Bluetooth 5.0,Weight-4.48kg,Operating System-macOS Big Sur,Processor- M1Echip,Line Voltage-100-240V AC) for Video Editing as per Department Incharge 740 Supplying of Photographic Design Flash Bender-Small Reflector:- 1) Make a bounce flash reflector, gobo, or snoot 2)Packs flat/great for travel 3)Attaches quickly & securely 4)Adjustable to fit all popular brands of accessory flash 5)For on-camera or off-camera flash as per Department Incharge 741 Supplying of Rim Collapsible softbox Diffuser with Rim :-1)Softbox 36 inches/90 Centimeters with Grey Rim and Bowens Mount, Portable and Quick Folding Softbox Diffuser for Photography Speedlites Flash Monolight 2)for 660 LED Panel-Outer 16.3x6.5 inches,Inner 9.8x8.7 inches Collapsible Light Reflector 3)with Stap Attachment and Carrying Bag for Photo Studio Portrait Video Shooting as per Department Incharge 742 Supplying of Handheld Camera Stabilizer with Quik Release for DSLR:- 1)Light weight, handheld video image stabilization 2)FlyCam 3000 video cam stabilizer accepts camera upto 3.5kg/7.7Ibs. 3)Easy attach a small LCD monitor with Flycam 3000 cam stabilizer when needed. 4)Precision Aluminum made 5)23 tall and just 207 Ibs without counter balance disc. as per Department Incharge 743 Supplying of Green/Blue matte screen )Chroma key( :- 1)8x12 ft Blackboard, perfect for television, video production and digital photography. 2)Rod pocket on each top edge allows to be draped or hung. 3)Finishing along all edges to prevent tears. 4)Made of 100 %pure cotton, good vertical sense and durable as per Department Incharge 744 Supplying of Professional Grade Backdrop Cum Light Stand of 8 Feet Height:- 1)Photography Backdrop Stand Kit. 2)Stand of 8 Feet Height 3)8x12 ft Blackboard, perfect for television, video production and digital photography. 4) Package Contents; 1Pcs White Backdrop , 1Pcs Black Backdrop and Set of Black Backdrop stand. 5)Bag to carry as per Department Incharge 745 Supplying of Video Mixer (Four Channel Digital Video Mixer With Effects, including installation and training):- 1) four channel video mixer by incorportating HDMI inputs/outputs, USB streaming, HDCP support, built-in touch multi-viewer, and audio embedding . 2)(3Input)SD HDMI/Composite +(1Input) Up to1080p HDMI/RGB/Component/Composite. 3) PGM Output) Up to 1080p HDMI + RGB/Component +Composite +(PVW Output)PVW/Multiviewer(. 4)480p/576p Progressive internal processing 5.) Built-in multi-viewer ith touch control 6). Built-in frame synchronizers on all inputs 7). Scalers on CH 4 and Output 8). 259 Transitions 148 Effects 9). HDCP Compliant 10) Audio Embedding 11) Audio Mixer & Delay -up to 4 Fframes 12) USB Streaming Out for web-streaming 13) Video Processing:4:2:2 )Y/b/Pr(8 bits)Internal Processing :480/59.94p when set to NTSC, 576/50p when set to PAL( 14) Input Formats :HDMIVideo: INPUT 1 to3 : reqyires 720x480/59.94p )when set to NTSC( 576/50p ) When set to PAL(15) Input Formats : HDMI and Component Video : INPUT 4:480/59.94p, 720/59.94p, 1080/59.94i, 1080/59.94p )when set to NTSC (576/50i, 576/50p, 720/50p, 1080/50i, 1080/50p )when set PAL( as per Department Incharge 746 Supplying of Studio Condenser Microphone :- 1)Professional, large-diaphragm condenser microphone for unsurpassed audio quality 2) Idea as Mian and support microphone for studio and live applications. 3) Cardioid pickup pattern for outstanding sound source separation and feedback rejection 4)Pressure-gradient transducer with shock-mounted capsule. 5)Ultra-low noise, transformerless FET inputeliminates low-frequency distortion. 6) LED indicates phantom power operation. 7)Swivel stand mount and transport case included. 8)Ultra-rugged construction with metal die-cast body 8)Gold-plated 3-pin XLR output connector for highest signal integrityas per Department Incharge 747 Supplying of Digital Monitor/Speaker System(in Pair) :- 1)Two-way active monitor system for multimedia workstations and keyboard monitoring 2)High-power woofers and tweeters powered provided a linear frequency response 3)optical and coaxial inputs to directly connect digital audio sources via S/PDIF interface 4)Two stereo analogue inputs featuring 1/8 TRS and stereo RCA connectors can be used simultaneously or mixed with a digital stereo source 5)Features 1/4 TRS headphone connector with auto-mute function easily accessible from the front panel 6)2x Stereo Anaog Inputs )TRS and Stereo RCA Connectors( 7) 1/4-inch TRS headphone connector with Auto-mute Loudspeaker Function 8)1/8-inch TRS and Stereo RCA connectors as per Department Incharge 748 Supplying of Lapel Clip-on Microphone for DSLRs Camcorders Video Cameras and Iphone Smart Phone :- 1)Omni directional lavalier microphone, designed for Smartphones, DSLR, Camcorders, Audio recorders PC etc, perfect for video use. 2) With Omni pickup pattern, for full 360A coverage, 3) minimum 6-meter )20(cable with 3.5mm 4-pole gold plug for smarty phone connection as per Department Incharge 749 Supplying of Micophone Stand:- Steel stands for hand held microphones in studio with a base supporting system as per Department Incharge 750 Supplying of MP3 Digital Voice IC Recorder LCD :- 1)Digital Voice IC Recorder 2)LCD Screen 3) 23hrs life with 4GB Memory as per Department Incharge
Contract Date: Jun 17, 2026 Contract Value : 78.07 Crore
Government Departments No of Bidders 9
40.
Health and Family Welfare #10187107 Price Bid
Tender For Electrification Work In Phc Building At Moriya District Phalodi - 1 (Electrical BSR 2022 Rajasthan) Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)inrecessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit & itsISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thickHot Dipped Galvanized Modular Box with earth terminal, 10A Modular switch,Modular face plate with grid plate, 3 pin ceiling rose / Holder /3 way connector, screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR. Short point (up to 3 mtr.) 2 Short point (up to 3 mtr.) 3 Medium point (up to 6 mtr.) 4 Long point(up to 10 mtr.) 5 Wiring of twin control light point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)in recessed ISI markedMMS ( IS:9537 P - III ) PVC conduit & its ISI marked (IS:3419-1988) accessories, round tiles, 2 Nos Hot Dipped Galvanized M.S Modularbox of 1.2 mm thickwith earth terminal,2 Nos10 A two way Modular switch, 3 pin ceiling rose / holder / 3 way connector ,Modular face plate with grid plate,screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR 6 Medium point (up to 6 mtr.) 7 Long point(up to 10 mtr.) 8 Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal sizeFR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) inrecessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & its ISI marked (IS:3419-1988)accessories, Hot Dipped GalvanizedModular box of 1.2 mm thick with earth terminal, 10 A modularswitch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR 9 On board 10 Supplying and fixing of power plug point with Modular accessories as per PWD specification for electrical Works, on hot dipped galvanized modular box of 1.2 mm thick with earthing terminal/connector on surface or in recessed with suitable size of modular face place with grid plate and cover plate including cost ofISI marked modular 16 amp. Switch (IS :3854) and 6/16 amp. socket outlet (IS:1293) making connection , testing , etc. as required. For specification ofWiring accessories refer ChapterE - 07related item & For additional technical parameters of product / work refer Annexure A attached with this BSR 11 Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 forlower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5,in existingsurface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure A attached with this BSR 12 3x 1.5 sq.mm 13 2 x 2.5 sq. mm. + 1x1.5sqmm 14 2 x 4.0 sq. mm. + 1 x 2.5 sq. mm. 15 4 x 10.0 sq.mm 16 4 x 6.0 sq.mm 17 1 x 2.5 sq.mm 18 Providing & Fixing of Recessed/surface mounting heavy duty horizontal type Double Door ( Metal / Glazed )Distribution board with Metal end box made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3, powder painted complete with reversible door (for double door DB only )100 amp. insulated copper bus bar/shorting link , copper neutral link, copper earth link , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, Ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 19 Metal door (Three phase) Per phase isolation, Horizontal IK-09 and IP-43 with Metal end box 20 6Way(Incomer 8,Sub Incomer2+2+2) 21 Metal door (single phase) IK-09 and IP-43 with Metal end box 22 16 Way (16+2) 23 Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load andsite requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting ofclass 3 as per IEC,minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted inexisting distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above ratingincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 24 Single pole MCB (With B/C curve tripping Characteristics) 25 6 A to 32 A rating 26 Four pole MCB (With B/C curve tripping Characteristics) 27 40 A rating 28 Double pole MCB(With B/C curve tripping Characteristics) 29 6 A to 32 A rating 30 S&F following sizes (dia.) of ISI marked virgin material MMS ( IS:9537 P - III ) PVC conduit along withISI marked (IS:3419-1988) accessories as requiredinrecessincludingcutting the wall, covering conduit and making good the same as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 31 20 mm 32 25 mm 33 P & F phenolic laminated sheet 2.0 mm thick of following size . Including screws, cup washer as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 34 75 mm dia 35 Providing & Fixing of modular type 120 W Step Fan regulator duly ISI marked (IS 11037:1984 ) with CM/L no. printedmade out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating ,includingall as per pre approved by Engineer in charge,making connections, testing etc. as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 36 5 step fan regulator 2 Module 360 dgree rotating 37 P & F 1.2mm thickM.S. Recessed fan box, hexagonal/ round of size 130 mm dia, depth 75mm,12 mm dia rod fan hook with 100 mmlength extended on each side . All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure A attached with this BSR 38 Providing & Fixing of Heavy duty capacitor start, copper woundDouble ball bearing900/1400 RPM single phaseExhaustfan conforming to IS:2312 ISI marked in existing opening including making connections testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 39 300 mm sweep(900/1400 RPM) 40 Providing & Fixing of IP20 SMD Mid Power LED batten type integrated light fixture made from Powder coated Extruded aluminiumhousing with in built driver, System lumen efficacy ≥ 110 lm/Watt output, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, CRI >80 , life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , Maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 41 1170mm(+/-10%) LED batten with min. lumen output 2200 lm 42 Providing & Fixing ofBEEStar rated copper wounded double ball bearing capacitor start, aluminium body & Metallicblade ceilingfanConforming to all the performance requirements laid down in IS 374:2019 including all amendments, as applicable ; & Carry BIS licensing (i.e. ISI marking) with down rod up to 80 cm with secondary support safety cable ( steel rope) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 43 1200 mm Sweep BEE 1 Star rated (service value >=4.0 to < 4.5 ) 44 Providing & Fixing ofof Double ball bearing, copper wounded capacitor startsingle phase metallicblade fresh air fan, in existing opening including cost of hardware , flexible 3 core copper conductor ,making connections, testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 45 225 mm sweep 46 Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed ArrmouredAluminiumcable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV withH4- Grade electrolyticaluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) includingtesting etc. as required of following size. OEM must have its own in house NABL accrediated Laboratory for testing procedure as per IS:10810.For additional technical parameters of product / work refer Annexure A attached with this BSR 47 25.0 Sq. mm 48 3.5 core 49 6.0 Sq. mm 50 2 core 51 Add Extra for Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV gradedirect in ground including excavation of trench of size 75 cm (Depth) x 35 cm(Width) ,with procedure as per followingpoints:- (a) Make a river sand bed of height 125 mm along the trench,(b) Lay the cable in the middle of the trench,(c) Provide river sand bed of height 125 mm on top of the cable, (d) Lay the protective Common burnt clay F.P.S. Bricks of Class designation 75 / Sand stone slabs of 50 mm thicknessand 225 mm widejust above the sand bed vertically across the cable ( Approx. 9 no. Bricks per Mtr.), (e) Backfill the excavated soil leaving 300 mm from the Ground level, (f)Lay the Cable warning tape and again back-fill the remaining portion of the trench upto the ground level and compacting the earth 52 Add Extra in item no. 11.1 to 11.4 for Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. 53 Up to 35 Sq.mm fixed with 25 mm x 2 mm thick suitable length red oxide and enamel painted MS clamp and base, pvc rawl plug and screws of sufficient size with spacing 0.6 Mtr. Between Clamps. 54 Supplyandinstallationofhigh tensile low carbon steel rod molecularly bonded with 99.9 % Copperthickness (250 microns) andconfirming toUL 467, IS/IEC 62561-2of following size and length and as per point mentioned (a), (b), [c), (d), (e) below :- 55 (a) Bore a hole of dia. 100 mm of required length, Place the rod in the centre of Hole 56 (b)filled with anti corrosiveconductivecompounds with the permanent sealings at both the ends, CPRI/ ERDAtested with RMS capacity of minimum 30 KA for withstanding 1 second .To ensure the moisture content and electrical conductivity, 25 kg for 2000 mm & 50 Kgs for 3000mm of resistance lowering earth enhancement material shall be used as a backfill compound. The compound shall be tested form NABL acredeated labfor lowresistivity ( less than 0.12 Ohm - meter ) & high conductivity in nature with carbon as a major contentas per referance of IS 3043-1987,IEEE 80-2013 (clause 14.5d) , IEEE 837 & IER 1956 with latest amendemnts 57 © Connect the rod with copper Strip/Conductor/Wire with suitable clamp made from tinned copper and SS 304 Bolt 58 (d) Place Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height250 to 300 mm. 59 (d)Testing of earth resistance for value of 5 ohms or lessas required & must record by engineer in charge during site visit and ensure to enter in measurment book. 60 (e) Test certificatesfor confirming above standards from OEM is mandatory. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 61 17.2 mm thick and 3 Mtr. Long 62 Supply & Laying following size earth wire in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles,making connection with GI/Cu purity purity >95%thimble etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 63 8 SWG G.I. ( Hot Dipped) Wire 64 Providing & Fixing of IK08, IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminummaterial with heat dissipation fins on housing with UV stabilized PC (UV stablization report submitted for UV cover ) /Toughened Glass coverand secondary lens on each LED & should be SMD type of 3 to 5 watt each . The System efficacy >=125 lm/ wt and potted driver& has a unique BIS R number withInput Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety , Power Factor >0.95 driverEfficiency >85%,THD(I) <10%Humidity 10% to 90% RH Working Temp -5C to 45C .driver current <750mA. The luminaireshall be BIS certified and Trade mark certified. Life ExpectancyEqual or more than 50000 burning hrs with Minimum 70% lumen maintened , CRI >70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external inside driver compartment. driver should be Phase to phase protection of 440 V for 4 Hrs.Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities forLED fixtures.(LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 65 LED Street Light fixture with Minimum lumen output 2450 lm 66 Providing & Fixing of Street light bracket made out from following size of B class , Medium class G.I. Pipe confirming to IS : 1239 P - 1 ( 2004 ) with heavy duty pole clamp, Saddles suitable fastners etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 67 25 mm Dia. 68 SITC of3 /4pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant materialhaving following current rating, short circuitbreaking capacityat 440/415 V, 50 Hz; O/L & S/C settings , conforming to IS/IEC 60947 P -2 :2003 with frontface and centralised adjustable, trip free mechanisum, true contact position indicator,line load interchangeability,designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree,pollution degree 3, having positive isolation capability, push(test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% Icu. U imp =8 KV, rated insulation voltage690 V.provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connectionsetc. as required.OEM shall have submitNABL / CPRI / ERDA accrediated lab type test certificate before execution All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 69 4 pole MCCB With Thermal Magnetic release 70 up to 100 Amp , 25 kA, adjustable O/L & adjustable S/C setting, 71 160 Amp , 25 kA, adjustable O/L & adjustable S/C setting, 72 Providing & Fixing of ding dong/musical chime bell as per PWD specification for electrical Works, including making connection testing etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 73 P&F metal clad / Plastic industrial plug top & socket unit with pin and sleeve type contact on porcelain/ bakelite base in Recessed/surface mounting heavy duty Enclosure made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3. powder painted (without MCB) including making connections, testing etc.as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 74 32 amp, 5 pin + scrapping Earth, 8 Module 75 Providing & Fixing of ISO certified company made on load change over switch, front handle operated, four pole 415 V as per PWD specificationfor electrical Works conforming to IS/lEC 60947-3 : 1999 including connections , testing etc. as required .in the following rating.Appropriate type test certificate / OEM test report shall be submitted .All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 76 Open execution type 77 63 A 78 Supply , Installation, Testing and Comissioning ofInverter type Air Cooled Hi Wall split type Air conditioners with latest star rating system as per BEE amended upto date complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU), R-32/R-410 Green Refrigerant, wireless Remote control, suitable for working between 230V +/- 10% with low & high voltage cutoff and50 hz , single phaseACsupply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 79 1.5 TR ISEER not less then 3.8 80 Providing & Fixing of IS : 4985 - 2000 Class -4 (10 Kgf / Sqcm) UPVC drain water piping withfittings (IS:7834 & 10Kgf/sqcm) like elbow, socket, Tee, solvent cement jointing,support with MS hanger on ceiling or recessed in wallwith chasing & plastering with 6 mmthickclosedcellelastomeric nitrile rubberinsulation including leakage testing etc. as required of following Nominal sizes. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 81 25 mm 82 Supply & fixing MS powder coated stand suitable for 1.0/1.5/ 2.0 Tr outdoor type of Split AC.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 83 Making hole in stone masonary/ RCC wall/ RCC slab with core cutter for accomodating refrigerant pipe/ drain pipe/ MS pipe/ cables etc of following dia 84 150 mm dia per running inch length 85 Supply, Fixing and testing of following capacity ISO certified company made wall mounted stabilizer having output voltage variation from 200 V to 250 V(+/-5%) with input voltage variation from 170 V to 260 V, time delay facility from 2 to 4 minute and high cutoff at 270 V with providing of 16 Amp /20 Amp Industrialplug top making connection etc complete in all respect.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 86 4 kVA 87 Providing & Fixing of IP-20 LED Recessed / Surface Mounted, Round / SqaureSMD Mid Power LED Downlight with power coated die-cast aluminum housingwith UV Stabilized non yellowish Diffuser withBIS complience 2.5 KV surge protected Isolated driver, with Short & Open circuit protection, having efficiency > 85% . System Lumen efficacy of ≥ 110 lm / watt, THD < 10 % , Pf.≥0.95, CRI >80,life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. 88 OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 89 Surface Mounting (with extruded alumn. Housing ) 90 Minimum lumen output 1950 lm 91 SITC of Monoblock motor pump set ISI marked (IS:9079-2002) with TEFC motor, motor should be IE2 class as per IEC 60034-2-1: 2007, IEC 60034-30: 2008,& IS12615:2011. with Stainless steel Impellor, Stainless steel shaft, Mechanical seal, Single/Three phase ( 240 - 440 V ) permanent split capacitor type (PSC), fitted with thermal overload protection, Including cost of hardware etc on existing platform complete. Pump shall have following HP Rating, phase, Head, minimum Discharge respectively complete in all respect. OEM shall have submitNABL / CPRI / ERDA accrediatedlab type test certificate before execution. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 92 1.0 HP, 1-Ø, (10-120)Mtr, (30-12) LPM 93 Supply & Fixing of Dry Powder Agent (as per IS 4308:2019), ABC typeFire Extinguisher (Stored Pressure type) conforming to IS:15683:2018 , Powder coated Internal & External Surface Deep drawn cylinder body of Mild Steel CR2 grade conforming to IS: 513, Squeeze grip Forged brass release valve with Inbuilt safety release device, Diaphragm Type, 0 to 28 bar range pressure gauge, 450 mm long EPDM discharge tube, QR code for Product Traceability including Fixing on wall with suitable Anchor Fasteners as required of following capacity. Test Certificates of all the Parameters along with Hydro test & Burst test (For Cylinder Body) Certificatefrom OEM / External NABL Accrediated Lab is to be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 94 4 kg 95 Providing & Fixing of Vertical(BEE 5 star rated) / Horizontal( BEE 3 star rated) storage water heater with outer casing made of Engineering Plastic sheet (Upto 25 Ltr) / Metal rust proof Body (35 & 50 Ltr), Glass - line / Titanium Enamel coated Pressure Pump Compatible 8 bar pressure Inner tank, Glass Line Coated , mineral filled heating element, stem type, snap actionadjustable thermostat , Dual indicating lampsInjected PUF insulation, Multi Function Valve etc. as required held in position with 2/4 no. 10/12 mm anchor Fastener, duly wired with 3 core 2.5/4.0 Sqmm PVC insulated & sheathed copper conductor and 16 A/25A three pin plug top with Portable Residual Current Device ( PRCD ) , including making inlet, outlet Flexible alloyconnection, testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 96 15 Ltr. 97 Supplying and drawing PE Insulated & PVC Sheathed unarmoured telephone cable with 0.5 mm dia. Solid Annealed electrolytic grade bare Copper Conductor as per IS: 8130/84 &confirming to TEC specification GR / WIR/06-03 March 2002in existingsurface or recessed conduit/casing capping. including ferruling on each pair for Identification etc. as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 98 2 pair 99 P & F Krone module with base framein the recess / surface made out of 1.2 mm thicksheet steel box, front openable, having locking arrangements duly powder painted,including dressing, ferrulingandpunchingof telephone cable with krone tool etc. as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 100 10 Pairs 101 Providing & Fixing of following modular accessories as per PWD specification for electrical Works,made out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating , includingall as per pre approved by Engineer in charge,making connections, testing etc. as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 102 RJ-11 telephone jack singleline 103 Supply, Drawing and Testing of 4 pair, 23 AWG Solid Bare Copper wire insulated with PVC, UTP (Unshielded Twisted Pair), Category 6, Class E, 100 Ohm Impedance, Indoor Cable as per latest ammendments of ANSI/TIA/EIA-568 , The copper conductors should be balanced twisted in pairs, seperated by a cross-member fluted pair divider & protected byPVC Jacket. Certified performance in a 4-connector configuration upto 100 Mtrs channel requirements & transmission frequencies up to 250 Mhz. in existing MS/PVC Conduits/casing capping including making connections to Information outlets and Patch Panels with jack &ferruling at both ends for identification with necessary tools for punching, stripping, crimping and testing etc as required complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 104 Supply and Installation of unsheilded/360 degree sheilded Information outlets made of high impact plastic body with ABS, FR Grade halogen free material with provision for protection against dust in jack, suitable for Cat 6/6A application complying to latest ammendments, According. to Cat. 6/6A channel, It should support channel as well as components requirements of Cat.6/6A standards at frequencies of up to 250 to 500 Mhz. Cat 6/6A unshielded/shielded Jack should be suitable to terminate 4 pair, 23/24 AWG solid/stranded wire diameters, using 100 Ohm unshielded/shielded balance twisted pair cable, the jack should have tooless/impact termination on reliable copper tin plated Insulation displacement contact, with easy lock mechanism, It supports IEC 60603-7-4 and complied with ANSI/TIA/EIA 568 C.2 standard. jack should be RJ11,RJ12 & RJ45 compatible. Should support Ethernet 1.2 Gb/s ATM,Digital video and broadband/baseband analog video, Voice over internet protocal (VOIP) Specifications in existing modular/MS Boxes along with necessory connections as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 105 Cat 6, Un-sheilded Information Outlet 106 Supply & fixing of square Faceplate for Flush / Surface Mount Information Outlets Single/Dual or Quad Aperture ,material should bePC+ABS body, Suitable for RJ45 unshielded/shielded connection modules. Should match with I. O. OEM. Dimensions should be 86mm X 86mm as required complete in all respect.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 107 Single Aperture 108 Supply & Installation of IP-20 & IK-08 , UL ListedWall mounted Double Section Communication enclosure (Rack) made from powder coated (60 to 80 Micron) CRCA sheet, front sturdy sheet steel frame folded from one piece and welded with minimum 5mm toughened glass door,Vertical Mounting Rail 1.6 MM with UMarking , with All round protective channel on the door aperture, lock integrated on front door, top and bottom cover with cable entry provision with gland plates, integrated side walls, 2 pair of 19 angles with wall mounting provision on wall. Accessories like: 1 No of 19 1U Horizontal Cable manager, 1 No of 90 cfm 230V AC Fan with 1 mts long cable, mounting hardware , 1 No of 19 1U, mountable socket strips with 5 nos of 5A universal sockets with 2 mts long power chord for supplying power to switches, fans etc along with earth continuity kit, indicator, moulded power supply cable. fixing on wall with Suitable Anchor fastneretc as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 109 6 U Rack with Width 600 mm &Depth 400 mm + 100 mm 110 Supply, Installation, Testing and Comissioning of Rack mounted 19 1U, Cat6 24 Port loaded, 1.5-1.6 MM CRS chasis, powder coated, sheet steel, made of plastic (ABS), Modular Patch Panelswith Rear Cable management system and mounting hardware to mount the patch panel. Should have port identification numbers printed/engraved on front of the panel. Etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 111 Modular Patch Panel Loaded with Cat -6 I/O 112 Supply , Installation, Testing and Comissioning ofUnmanaged Switch Plug-and-play - easy setup with no configuration or no software needed, following Port fast ethernet - 8 port 10/100 MBPS auto-negotiation RJ45 ports,IEEE 802.3x flow control ,supports auto-MDI/MDIX, eliminating the need for crossover cables including making connection etc as required complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 113 24 Port 114 Providing & Fixing of IP20, 2x2 LED Surface/ Recessedmounting Mid power SMD type LED Light fixture not less than 50mm housing depth made from CRCA sheet steel housing, high purity / transmisivity UV stabilized Non -yellowish diffuser for uniform light distribution. High efficiency with 4 KV internal/external surge protection BIS certified isolated driver having efficiency > 85% , with Short & Open circuit protection(Integral with light fixture). System lumen efficacy of ≥ 120 lm/Watt ,THD < 10 % , p.f.≥0.95,CRI >80 ,life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. 115 OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted.All as per pre approved by Engineer in charge. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 116 Recessed Mounting 117 Minimum lumen output 4200 lm 118 Supply , Installation and Testing of 4 pair, 100 Ohm impedance, Cat 6/6A /Class E/Ea patch cords should be constructed of minimum 23/24 AWG, stranded bare Copper cable with FRPVC/LSZH Jacket, with an enhanced performance by factory moulded RJ45 connectors with strain relief boots as per ANSI/TIA/EIA 568-C.2 suitable for Cat 6/6A application complying to latest ammendments Category 6/6A Standards, According. to TIA568C.2, ISO/IEC 11801, EN 50173, IEC 60603-7-51, EN 60603-7, IEEE 802.3an minimum requirement for 1G BASE-T to 10G BASE-T performance. Patch cords shall be straight thru cable compatible with both T568-A and T568-B wiring schemes, should support IEEE 802.3af / IEEE 802.3at for POE applications, Minimum 750 to 1000 mating cycles in plug contacts for long durability, Should support Ethernet 10GBASE-T, 1.2 Gb/s ATM, Token ring 4/16, Digital video and broadband/baseband analog video, Voice over internet protocal (VOIP).All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 119 Cat 6, U/UTP (Unscreened/Un-sheilded Twisted Pair) Patch Cord 120 1 Mtr 121 Supplying and making one end termination with Nickel plated heavy duty brass single compression gland (as per IS 12943-1990)) SIBG type consisting of Check Nut, Gland Body, Metal Washer(3 Nos.), Outer Seal Rubber Ring,Compression Nut,heavy duty aluminium lugs (as per IS 8309 -1993) duly crimped with crimping tool, PVC tape as perIS 8337-1976offollowing size ofPVC insulated & PVC sheathed/ XLPE aluminium conductor cable of 1100 volt grade as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 122 3.5 x 25.0 sq.mm 123 Supply, installation, testing and comissioning ofinterconnectingcopperrefrigerant pipingof DHE Grade C12200- ASTM B68, B75, chemical composition of copper %- 99.0 Min and Phosphorus %- 0.015 to 0.040 . For Annealed copper tube :- Tensile strength = 210 Mpa wih elongation % = 40 Min . Ink MarkBrand Printing on Hard Tubes should be present. duly insulated with tubular elastomeric nitrile rubber FM/UL approved with high water vapor diffusion resistance and low thermal conductivity should be certified Class O in Fire Propagationas per BS 476 Part 6 including chase cutting andfilling with mortar, Slotted channel supports mounted on 10 mm threaded rod at suitable spacing the exposed piping shall be wrapped with glass woven cloth and lag coating for vapour barrier and weather protection. Joints shall be covered with nitrile rubber tape of 3 mm thick complete as required of following sizes. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 124 12.7 mm O.D., wall thinkness ≥ 0.8mm (insulation – 13 mm thick) 125 6.4 mm O.D., wall thinkness ≥ 0.8mm (insulation – 13 mm thick) 126 Supply , Installation, Testing and Comissioning of IS:1475 marked self contained drinking water cooler withhermeticallysealed compressor,non CFC refrigerent suitable for operation on 230V/1pH/50Hz AC supply,Full stainless steel (SS304)body (0.8 mm thick)and tank (0.5 mm thick) , stainless steel water tray,minimum two nosBrass Chrome plated faucets and suitable drainage system complete in all respect with requiredheight MS fabricated and Painted Angle iron frame( Cost of frame to be paid Extra )complete in all respect of the following capacity.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 127 cooling capacity 150 Ltr./Hr. and storage capacity 150 Ltrs 128 Providing and fixing welded mesh/expanded metal mesh 25 mmx 25 mm x 3mm in frame work, flat iron beading 20x3mm including top cross laps inside and out sides welding, iron bolts, crews, clips etc. including two coat of red oxide and two coat of enamel paint or more requiredcomplete with frame work with 50 X 50 X 6mm angle iron post 30 cm in ground embeded in cement concrete 1:3:6 (30X30X45cm) at corner and every three mtr including painting with one coat of primer and two coat of enamel paint work will be done as per direction of engineer incharge of sizecomplete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 129 SITC of IP-42 and general construction confirming to IS:8623 : 1993, wall/ free standing floor mounted dust and vermin proof compartmentalisedcubical panel as specifications andOther parameters requiredas per point (a) ,(b), (c),(d), (e), (f), (g), (h) as below:- 130 (a)Thickness of CRCA sheet shallbe 2.0 mm,cable alley compartments having concealed hinged type doors with key type lock with / withoutdetachable extension type structure. Removable 3 mm. thick sheet steel gland plates with appropriate size of knockouts for cables shall be provided 131 (b)complete panel shall undergo a process of degreasing, Water rinsing, Activation, derusting,pickling in acid bath, phosphatising & shall be subjected to nine tank process and then Powder coated with approved shade of minimum 70 microns on both side of panel.The panel having PE foam/ Neoprene rubber gasket of not less than 3mm thickness ,required hardware , concealed hinged door with key type locking arrangement for equipment/switchgear earthed with 2.5 sq.mm braided copper wire. 132 [c)Interconnection between bus bar and switchgears /cable shall be rigidly supported and made out by flexible copper wires (up to 63 amp ) and by solid bus bar(>63 amp ) . control wiring will be carried out with 1.5 Sq.mm, Earth wire with 2.5 Sq.mm and CT with 2.5 sq.mm flexible copper wire only.All joints / interconnections of copper bus bar shall be dully tinned . Clearance between main bus bar and risers / metal parts shall be at least 10 mm additional to width of bus bar Bus bar is insulated by Heat Shrinkable sleeves . Earth and Neutral bus bar shall be half of the size of phase bus bar. ( Cost of Bus bar/ Flexible wire for Interconnection between Main busbar and Switchgearis to be Paid Extra ) 133 (d)Wiring between components within switchgear and Incoming / outgoing cableshall be done through the terminal block only. Direct connection shall not be permitted. Each terminal block shall be one piece moulded, barrier type, 650 volt grade, complete with washers, heads, studs with two nuts and identification strips and shall have adequate continuous current rating. For tap-offs, adjacent terminals with shorting strips shall be used. 10% Spare terminal blocks shall be provided. Wire identification on marking strip shall correspond to the designation of the wiring diagrams. All wire terminals on the equipment shall also be marked with designation corresponding to those of the wiring diagram. 134 (e)All wiring shall be enclosed in plastic channels and neatly bunched and closed in metering chamber, Wiring between terminals of various devices shall be ‘point to point’ (no wire splitting or tee connections) with wires neatly trucked along the back of the panels, adequately supported to prevent sagging. 135 (f)Floor mounted panel shall be mounted on Base frame of ISMCchannel size 100 x 50 x 5 mm( to be paid Extra ) 136 (g) Tests: The insulation resistance (with 1000 V Megger) and High voltage Power frequency test (by applying a voltage of 2.5KV for one minute) shall be measured between phases, between phase and neutral and between phase and earth. both before and after high voltage power frequency test. The insulation resistance shall not be less than three megaohm. CT Secondary current injection test shall also be carried out. 137 (h) only outer surface area on all sides shall be measured & panel to be fabricated only from CPRI approved fabricator only (CPRI Test certificates to be submitted)All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 138 Providing & Fixing of BIS approvedCurrent Transformeras per PWD specification for electrical Works ,ISI marked as perIS 2705-1992/ conforming to IEC 60044-1, with secondary terminalof CT shall be brought out suitable to a terminal block which shall be easier accessible for testing and terminal connection , with all necessary support in existing panel including connection etc. as requiredCurrent transformer Ring Type Tape Wound/Resin Cast Wound as per IS 16227 with, Accuracy Cl, CT ratio and burden as specified. ISF<=5, Cu cross section of secondary wire 1.5sqmm (minimum), including all necessary support in existing panel including connection etc. as required . All as per pre approved by Engineer in charge.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 139 Ring type tape wound CT 140 C T Class 1, Ratio 200/5 to 300/5, Burden 10 VA 141 Providing & Fixing of110/220 V, unibody LED Indicatinglamp IEC 60947with integral circuit, IP 65 above panel &IP 20 terminal block, Approx. body dia for panel not less then 20 mm, length min. 50mm, front LED cover dia min.29 mm, contact material phospher bronze for Led, PCB contacts shall be ofbrass (tin plated), impulsedielectric tested for 2.5 KV, Rated insulation resistance shall be 100 M ohm at 500VDCincluding connection etc. as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 142 Red/yellow/Green colour 143 Supplying and fixing of Aluminium (IEC 60105 ISO 209-1,2) / Copper (IEC 60028) bus bar by means of SMC / DMC type insulatorwith standard short circuit withstand capacity, high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable PVC sleeves. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 144 Electrolytic grade Aluminium bus bar 6010 grade
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
41.
Health and Family Welfare #10187103 Price Bid
Tender For Electrification Work In Phc Building At Bhudkiya District Jodhpur Rural - 1 (Electrical BSR 2022 Rajasthan) Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)inrecessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit & itsISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thickHot Dipped Galvanized Modular Box with earth terminal, 10A Modular switch,Modular face plate with grid plate, 3 pin ceiling rose / Holder /3 way connector, screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR. Short point (up to 3 mtr.) 2 Short point (up to 3 mtr.) 3 Medium point (up to 6 mtr.) 4 Long point(up to 10 mtr.) 5 Wiring of twin control light point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)in recessed ISI markedMMS ( IS:9537 P - III ) PVC conduit & its ISI marked (IS:3419-1988) accessories, round tiles, 2 Nos Hot Dipped Galvanized M.S Modularbox of 1.2 mm thickwith earth terminal,2 Nos10 A two way Modular switch, 3 pin ceiling rose / holder / 3 way connector ,Modular face plate with grid plate,screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR 6 Medium point (up to 6 mtr.) 7 Long point(up to 10 mtr.) 8 Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal sizeFR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) inrecessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & its ISI marked (IS:3419-1988)accessories, Hot Dipped GalvanizedModular box of 1.2 mm thick with earth terminal, 10 A modularswitch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR 9 On board 10 Supplying and fixing of power plug point with Modular accessories as per PWD specification for electrical Works, on hot dipped galvanized modular box of 1.2 mm thick with earthing terminal/connector on surface or in recessed with suitable size of modular face place with grid plate and cover plate including cost ofISI marked modular 16 amp. Switch (IS :3854) and 6/16 amp. socket outlet (IS:1293) making connection , testing , etc. as required. For specification ofWiring accessories refer ChapterE - 07related item & For additional technical parameters of product / work refer Annexure A attached with this BSR 11 Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 forlower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5,in existingsurface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure A attached with this BSR 12 3x 1.5 sq.mm 13 2 x 2.5 sq. mm. + 1x1.5sqmm 14 2 x 4.0 sq. mm. + 1 x 2.5 sq. mm. 15 4 x 10.0 sq.mm 16 4 x 6.0 sq.mm 17 1 x 2.5 sq.mm 18 Providing & Fixing of Recessed/surface mounting heavy duty horizontal type Double Door ( Metal / Glazed )Distribution board with Metal end box made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3, powder painted complete with reversible door (for double door DB only )100 amp. insulated copper bus bar/shorting link , copper neutral link, copper earth link , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, Ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 19 Metal door (Three phase) Per phase isolation, Horizontal IK-09 and IP-43 with Metal end box 20 6Way(Incomer 8,Sub Incomer2+2+2) 21 Metal door (single phase) IK-09 and IP-43 with Metal end box 22 16 Way (16+2) 23 Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load andsite requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting ofclass 3 as per IEC,minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted inexisting distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above ratingincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 24 Single pole MCB (With B/C curve tripping Characteristics) 25 6 A to 32 A rating 26 Four pole MCB (With B/C curve tripping Characteristics) 27 40 A rating 28 Double pole MCB(With B/C curve tripping Characteristics) 29 6 A to 32 A rating 30 S&F following sizes (dia.) of ISI marked virgin material MMS ( IS:9537 P - III ) PVC conduit along withISI marked (IS:3419-1988) accessories as requiredinrecessincludingcutting the wall, covering conduit and making good the same as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 31 20 mm 32 25 mm 33 P & F phenolic laminated sheet 2.0 mm thick of following size . Including screws, cup washer as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 34 75 mm dia 35 Providing & Fixing of modular type 120 W Step Fan regulator duly ISI marked (IS 11037:1984 ) with CM/L no. printedmade out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating ,includingall as per pre approved by Engineer in charge,making connections, testing etc. as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 36 5 step fan regulator 2 Module 360 dgree rotating 37 P & F 1.2mm thickM.S. Recessed fan box, hexagonal/ round of size 130 mm dia, depth 75mm,12 mm dia rod fan hook with 100 mmlength extended on each side . All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure A attached with this BSR 38 Providing & Fixing of Heavy duty capacitor start, copper woundDouble ball bearing900/1400 RPM single phaseExhaustfan conforming to IS:2312 ISI marked in existing opening including making connections testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 39 300 mm sweep(900/1400 RPM) 40 Providing & Fixing of IP20 SMD Mid Power LED batten type integrated light fixture made from Powder coated Extruded aluminiumhousing with in built driver, System lumen efficacy ≥ 110 lm/Watt output, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, CRI >80 , life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , Maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 41 1170mm(+/-10%) LED batten with min. lumen output 2200 lm 42 Providing & Fixing ofBEEStar rated copper wounded double ball bearing capacitor start, aluminium body & Metallicblade ceilingfanConforming to all the performance requirements laid down in IS 374:2019 including all amendments, as applicable ; & Carry BIS licensing (i.e. ISI marking) with down rod up to 80 cm with secondary support safety cable ( steel rope) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 43 1200 mm Sweep BEE 1 Star rated (service value >=4.0 to < 4.5 ) 44 Providing & Fixing ofof Double ball bearing, copper wounded capacitor startsingle phase metallicblade fresh air fan, in existing opening including cost of hardware , flexible 3 core copper conductor ,making connections, testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 45 225 mm sweep 46 Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed ArrmouredAluminiumcable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV withH4- Grade electrolyticaluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) includingtesting etc. as required of following size. OEM must have its own in house NABL accrediated Laboratory for testing procedure as per IS:10810.For additional technical parameters of product / work refer Annexure A attached with this BSR 47 25.0 Sq. mm 48 3.5 core 49 6.0 Sq. mm 50 2 core 51 Add Extra for Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV gradedirect in ground including excavation of trench of size 75 cm (Depth) x 35 cm(Width) ,with procedure as per followingpoints:- (a) Make a river sand bed of height 125 mm along the trench,(b) Lay the cable in the middle of the trench,(c) Provide river sand bed of height 125 mm on top of the cable, (d) Lay the protective Common burnt clay F.P.S. Bricks of Class designation 75 / Sand stone slabs of 50 mm thicknessand 225 mm widejust above the sand bed vertically across the cable ( Approx. 9 no. Bricks per Mtr.), (e) Backfill the excavated soil leaving 300 mm from the Ground level, (f)Lay the Cable warning tape and again back-fill the remaining portion of the trench upto the ground level and compacting the earth 52 Add Extra in item no. 11.1 to 11.4 for Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. 53 Up to 35 Sq.mm fixed with 25 mm x 2 mm thick suitable length red oxide and enamel painted MS clamp and base, pvc rawl plug and screws of sufficient size with spacing 0.6 Mtr. Between Clamps. 54 Supplyandinstallationofhigh tensile low carbon steel rod molecularly bonded with 99.9 % Copperthickness (250 microns) andconfirming toUL 467, IS/IEC 62561-2of following size and length and as per point mentioned (a), (b), [c), (d), (e) below :- 55 (a) Bore a hole of dia. 100 mm of required length, Place the rod in the centre of Hole 56 (b)filled with anti corrosiveconductivecompounds with the permanent sealings at both the ends, CPRI/ ERDAtested with RMS capacity of minimum 30 KA for withstanding 1 second .To ensure the moisture content and electrical conductivity, 25 kg for 2000 mm & 50 Kgs for 3000mm of resistance lowering earth enhancement material shall be used as a backfill compound. The compound shall be tested form NABL acredeated labfor lowresistivity ( less than 0.12 Ohm - meter ) & high conductivity in nature with carbon as a major contentas per referance of IS 3043-1987,IEEE 80-2013 (clause 14.5d) , IEEE 837 & IER 1956 with latest amendemnts 57 © Connect the rod with copper Strip/Conductor/Wire with suitable clamp made from tinned copper and SS 304 Bolt 58 (d) Place Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height250 to 300 mm. 59 (d)Testing of earth resistance for value of 5 ohms or lessas required & must record by engineer in charge during site visit and ensure to enter in measurment book. 60 (e) Test certificatesfor confirming above standards from OEM is mandatory. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 61 17.2 mm thick and 3 Mtr. Long 62 Supply & Laying following size earth wire in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles,making connection with GI/Cu purity purity >95%thimble etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 63 8 SWG G.I. ( Hot Dipped) Wire 64 Providing & Fixing of IK08, IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminummaterial with heat dissipation fins on housing with UV stabilized PC (UV stablization report submitted for UV cover ) /Toughened Glass coverand secondary lens on each LED & should be SMD type of 3 to 5 watt each . The System efficacy >=125 lm/ wt and potted driver& has a unique BIS R number withInput Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety , Power Factor >0.95 driverEfficiency >85%,THD(I) <10%Humidity 10% to 90% RH Working Temp -5C to 45C .driver current <750mA. The luminaireshall be BIS certified and Trade mark certified. Life ExpectancyEqual or more than 50000 burning hrs with Minimum 70% lumen maintened , CRI >70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external inside driver compartment. driver should be Phase to phase protection of 440 V for 4 Hrs.Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities forLED fixtures.(LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 65 LED Street Light fixture with Minimum lumen output 2450 lm 66 Providing & Fixing of Street light bracket made out from following size of B class , Medium class G.I. Pipe confirming to IS : 1239 P - 1 ( 2004 ) with heavy duty pole clamp, Saddles suitable fastners etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 67 25 mm Dia. 68 SITC of3 /4pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant materialhaving following current rating, short circuitbreaking capacityat 440/415 V, 50 Hz; O/L & S/C settings , conforming to IS/IEC 60947 P -2 :2003 with frontface and centralised adjustable, trip free mechanisum, true contact position indicator,line load interchangeability,designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree,pollution degree 3, having positive isolation capability, push(test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% Icu. U imp =8 KV, rated insulation voltage690 V.provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connectionsetc. as required.OEM shall have submitNABL / CPRI / ERDA accrediated lab type test certificate before execution All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 69 4 pole MCCB With Thermal Magnetic release 70 up to 100 Amp , 25 kA, adjustable O/L & adjustable S/C setting, 71 160 Amp , 25 kA, adjustable O/L & adjustable S/C setting, 72 Providing & Fixing of ding dong/musical chime bell as per PWD specification for electrical Works, including making connection testing etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 73 P&F metal clad / Plastic industrial plug top & socket unit with pin and sleeve type contact on porcelain/ bakelite base in Recessed/surface mounting heavy duty Enclosure made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3. powder painted (without MCB) including making connections, testing etc.as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 74 32 amp, 5 pin + scrapping Earth, 8 Module 75 Providing & Fixing of ISO certified company made on load change over switch, front handle operated, four pole 415 V as per PWD specificationfor electrical Works conforming to IS/lEC 60947-3 : 1999 including connections , testing etc. as required .in the following rating.Appropriate type test certificate / OEM test report shall be submitted .All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 76 Open execution type 77 63 A 78 Supply , Installation, Testing and Comissioning ofInverter type Air Cooled Hi Wall split type Air conditioners with latest star rating system as per BEE amended upto date complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU), R-32/R-410 Green Refrigerant, wireless Remote control, suitable for working between 230V +/- 10% with low & high voltage cutoff and50 hz , single phaseACsupply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 79 1.5 TR ISEER not less then 3.8 80 Providing & Fixing of IS : 4985 - 2000 Class -4 (10 Kgf / Sqcm) UPVC drain water piping withfittings (IS:7834 & 10Kgf/sqcm) like elbow, socket, Tee, solvent cement jointing,support with MS hanger on ceiling or recessed in wallwith chasing & plastering with 6 mmthickclosedcellelastomeric nitrile rubberinsulation including leakage testing etc. as required of following Nominal sizes. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 81 25 mm 82 Supply & fixing MS powder coated stand suitable for 1.0/1.5/ 2.0 Tr outdoor type of Split AC.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 83 Making hole in stone masonary/ RCC wall/ RCC slab with core cutter for accomodating refrigerant pipe/ drain pipe/ MS pipe/ cables etc of following dia 84 150 mm dia per running inch length 85 Supply, Fixing and testing of following capacity ISO certified company made wall mounted stabilizer having output voltage variation from 200 V to 250 V(+/-5%) with input voltage variation from 170 V to 260 V, time delay facility from 2 to 4 minute and high cutoff at 270 V with providing of 16 Amp /20 Amp Industrialplug top making connection etc complete in all respect.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 86 4 kVA 87 Providing & Fixing of IP-20 LED Recessed / Surface Mounted, Round / SqaureSMD Mid Power LED Downlight with power coated die-cast aluminum housingwith UV Stabilized non yellowish Diffuser withBIS complience 2.5 KV surge protected Isolated driver, with Short & Open circuit protection, having efficiency > 85% . System Lumen efficacy of ≥ 110 lm / watt, THD < 10 % , Pf.≥0.95, CRI >80,life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. 88 OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 89 Surface Mounting (with extruded alumn. Housing ) 90 Minimum lumen output 1950 lm 91 SITC of Monoblock motor pump set ISI marked (IS:9079-2002) with TEFC motor, motor should be IE2 class as per IEC 60034-2-1: 2007, IEC 60034-30: 2008,& IS12615:2011. with Stainless steel Impellor, Stainless steel shaft, Mechanical seal, Single/Three phase ( 240 - 440 V ) permanent split capacitor type (PSC), fitted with thermal overload protection, Including cost of hardware etc on existing platform complete. Pump shall have following HP Rating, phase, Head, minimum Discharge respectively complete in all respect. OEM shall have submitNABL / CPRI / ERDA accrediatedlab type test certificate before execution. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 92 1.0 HP, 1-Ø, (10-120)Mtr, (30-12) LPM 93 Supply & Fixing of Dry Powder Agent (as per IS 4308:2019), ABC typeFire Extinguisher (Stored Pressure type) conforming to IS:15683:2018 , Powder coated Internal & External Surface Deep drawn cylinder body of Mild Steel CR2 grade conforming to IS: 513, Squeeze grip Forged brass release valve with Inbuilt safety release device, Diaphragm Type, 0 to 28 bar range pressure gauge, 450 mm long EPDM discharge tube, QR code for Product Traceability including Fixing on wall with suitable Anchor Fasteners as required of following capacity. Test Certificates of all the Parameters along with Hydro test & Burst test (For Cylinder Body) Certificatefrom OEM / External NABL Accrediated Lab is to be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 94 4 kg 95 Providing & Fixing of Vertical(BEE 5 star rated) / Horizontal( BEE 3 star rated) storage water heater with outer casing made of Engineering Plastic sheet (Upto 25 Ltr) / Metal rust proof Body (35 & 50 Ltr), Glass - line / Titanium Enamel coated Pressure Pump Compatible 8 bar pressure Inner tank, Glass Line Coated , mineral filled heating element, stem type, snap actionadjustable thermostat , Dual indicating lampsInjected PUF insulation, Multi Function Valve etc. as required held in position with 2/4 no. 10/12 mm anchor Fastener, duly wired with 3 core 2.5/4.0 Sqmm PVC insulated & sheathed copper conductor and 16 A/25A three pin plug top with Portable Residual Current Device ( PRCD ) , including making inlet, outlet Flexible alloyconnection, testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 96 15 Ltr. 97 Supplying and drawing PE Insulated & PVC Sheathed unarmoured telephone cable with 0.5 mm dia. Solid Annealed electrolytic grade bare Copper Conductor as per IS: 8130/84 &confirming to TEC specification GR / WIR/06-03 March 2002in existingsurface or recessed conduit/casing capping. including ferruling on each pair for Identification etc. as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 98 2 pair 99 P & F Krone module with base framein the recess / surface made out of 1.2 mm thicksheet steel box, front openable, having locking arrangements duly powder painted,including dressing, ferrulingandpunchingof telephone cable with krone tool etc. as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 100 10 Pairs 101 Providing & Fixing of following modular accessories as per PWD specification for electrical Works,made out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating , includingall as per pre approved by Engineer in charge,making connections, testing etc. as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 102 RJ-11 telephone jack singleline 103 Supply, Drawing and Testing of 4 pair, 23 AWG Solid Bare Copper wire insulated with PVC, UTP (Unshielded Twisted Pair), Category 6, Class E, 100 Ohm Impedance, Indoor Cable as per latest ammendments of ANSI/TIA/EIA-568 , The copper conductors should be balanced twisted in pairs, seperated by a cross-member fluted pair divider & protected byPVC Jacket. Certified performance in a 4-connector configuration upto 100 Mtrs channel requirements & transmission frequencies up to 250 Mhz. in existing MS/PVC Conduits/casing capping including making connections to Information outlets and Patch Panels with jack &ferruling at both ends for identification with necessary tools for punching, stripping, crimping and testing etc as required complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 104 Supply and Installation of unsheilded/360 degree sheilded Information outlets made of high impact plastic body with ABS, FR Grade halogen free material with provision for protection against dust in jack, suitable for Cat 6/6A application complying to latest ammendments, According. to Cat. 6/6A channel, It should support channel as well as components requirements of Cat.6/6A standards at frequencies of up to 250 to 500 Mhz. Cat 6/6A unshielded/shielded Jack should be suitable to terminate 4 pair, 23/24 AWG solid/stranded wire diameters, using 100 Ohm unshielded/shielded balance twisted pair cable, the jack should have tooless/impact termination on reliable copper tin plated Insulation displacement contact, with easy lock mechanism, It supports IEC 60603-7-4 and complied with ANSI/TIA/EIA 568 C.2 standard. jack should be RJ11,RJ12 & RJ45 compatible. Should support Ethernet 1.2 Gb/s ATM,Digital video and broadband/baseband analog video, Voice over internet protocal (VOIP) Specifications in existing modular/MS Boxes along with necessory connections as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 105 Cat 6, Un-sheilded Information Outlet 106 Supply & fixing of square Faceplate for Flush / Surface Mount Information Outlets Single/Dual or Quad Aperture ,material should bePC+ABS body, Suitable for RJ45 unshielded/shielded connection modules. Should match with I. O. OEM. Dimensions should be 86mm X 86mm as required complete in all respect.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 107 Single Aperture 108 Supply & Installation of IP-20 & IK-08 , UL ListedWall mounted Double Section Communication enclosure (Rack) made from powder coated (60 to 80 Micron) CRCA sheet, front sturdy sheet steel frame folded from one piece and welded with minimum 5mm toughened glass door,Vertical Mounting Rail 1.6 MM with UMarking , with All round protective channel on the door aperture, lock integrated on front door, top and bottom cover with cable entry provision with gland plates, integrated side walls, 2 pair of 19 angles with wall mounting provision on wall. Accessories like: 1 No of 19 1U Horizontal Cable manager, 1 No of 90 cfm 230V AC Fan with 1 mts long cable, mounting hardware , 1 No of 19 1U, mountable socket strips with 5 nos of 5A universal sockets with 2 mts long power chord for supplying power to switches, fans etc along with earth continuity kit, indicator, moulded power supply cable. fixing on wall with Suitable Anchor fastneretc as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 109 6 U Rack with Width 600 mm &Depth 400 mm + 100 mm 110 Supply, Installation, Testing and Comissioning of Rack mounted 19 1U, Cat6 24 Port loaded, 1.5-1.6 MM CRS chasis, powder coated, sheet steel, made of plastic (ABS), Modular Patch Panelswith Rear Cable management system and mounting hardware to mount the patch panel. Should have port identification numbers printed/engraved on front of the panel. Etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 111 Modular Patch Panel Loaded with Cat -6 I/O 112 Supply , Installation, Testing and Comissioning ofUnmanaged Switch Plug-and-play - easy setup with no configuration or no software needed, following Port fast ethernet - 8 port 10/100 MBPS auto-negotiation RJ45 ports,IEEE 802.3x flow control ,supports auto-MDI/MDIX, eliminating the need for crossover cables including making connection etc as required complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 113 24 Port 114 Providing & Fixing of IP20, 2x2 LED Surface/ Recessedmounting Mid power SMD type LED Light fixture not less than 50mm housing depth made from CRCA sheet steel housing, high purity / transmisivity UV stabilized Non -yellowish diffuser for uniform light distribution. High efficiency with 4 KV internal/external surge protection BIS certified isolated driver having efficiency > 85% , with Short & Open circuit protection(Integral with light fixture). System lumen efficacy of ≥ 120 lm/Watt ,THD < 10 % , p.f.≥0.95,CRI >80 ,life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. 115 OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted.All as per pre approved by Engineer in charge. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 116 Recessed Mounting 117 Minimum lumen output 4200 lm 118 Supply , Installation and Testing of 4 pair, 100 Ohm impedance, Cat 6/6A /Class E/Ea patch cords should be constructed of minimum 23/24 AWG, stranded bare Copper cable with FRPVC/LSZH Jacket, with an enhanced performance by factory moulded RJ45 connectors with strain relief boots as per ANSI/TIA/EIA 568-C.2 suitable for Cat 6/6A application complying to latest ammendments Category 6/6A Standards, According. to TIA568C.2, ISO/IEC 11801, EN 50173, IEC 60603-7-51, EN 60603-7, IEEE 802.3an minimum requirement for 1G BASE-T to 10G BASE-T performance. Patch cords shall be straight thru cable compatible with both T568-A and T568-B wiring schemes, should support IEEE 802.3af / IEEE 802.3at for POE applications, Minimum 750 to 1000 mating cycles in plug contacts for long durability, Should support Ethernet 10GBASE-T, 1.2 Gb/s ATM, Token ring 4/16, Digital video and broadband/baseband analog video, Voice over internet protocal (VOIP).All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 119 Cat 6, U/UTP (Unscreened/Un-sheilded Twisted Pair) Patch Cord 120 1 Mtr 121 Supplying and making one end termination with Nickel plated heavy duty brass single compression gland (as per IS 12943-1990)) SIBG type consisting of Check Nut, Gland Body, Metal Washer(3 Nos.), Outer Seal Rubber Ring,Compression Nut,heavy duty aluminium lugs (as per IS 8309 -1993) duly crimped with crimping tool, PVC tape as perIS 8337-1976offollowing size ofPVC insulated & PVC sheathed/ XLPE aluminium conductor cable of 1100 volt grade as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 122 3.5 x 25.0 sq.mm 123 Supply, installation, testing and comissioning ofinterconnectingcopperrefrigerant pipingof DHE Grade C12200- ASTM B68, B75, chemical composition of copper %- 99.0 Min and Phosphorus %- 0.015 to 0.040 . For Annealed copper tube :- Tensile strength = 210 Mpa wih elongation % = 40 Min . Ink MarkBrand Printing on Hard Tubes should be present. duly insulated with tubular elastomeric nitrile rubber FM/UL approved with high water vapor diffusion resistance and low thermal conductivity should be certified Class O in Fire Propagationas per BS 476 Part 6 including chase cutting andfilling with mortar, Slotted channel supports mounted on 10 mm threaded rod at suitable spacing the exposed piping shall be wrapped with glass woven cloth and lag coating for vapour barrier and weather protection. Joints shall be covered with nitrile rubber tape of 3 mm thick complete as required of following sizes. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 124 12.7 mm O.D., wall thinkness ≥ 0.8mm (insulation – 13 mm thick) 125 6.4 mm O.D., wall thinkness ≥ 0.8mm (insulation – 13 mm thick) 126 Supply , Installation, Testing and Comissioning of IS:1475 marked self contained drinking water cooler withhermeticallysealed compressor,non CFC refrigerent suitable for operation on 230V/1pH/50Hz AC supply,Full stainless steel (SS304)body (0.8 mm thick)and tank (0.5 mm thick) , stainless steel water tray,minimum two nosBrass Chrome plated faucets and suitable drainage system complete in all respect with requiredheight MS fabricated and Painted Angle iron frame( Cost of frame to be paid Extra )complete in all respect of the following capacity.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 127 cooling capacity 150 Ltr./Hr. and storage capacity 150 Ltrs 128 Providing and fixing welded mesh/expanded metal mesh 25 mmx 25 mm x 3mm in frame work, flat iron beading 20x3mm including top cross laps inside and out sides welding, iron bolts, crews, clips etc. including two coat of red oxide and two coat of enamel paint or more requiredcomplete with frame work with 50 X 50 X 6mm angle iron post 30 cm in ground embeded in cement concrete 1:3:6 (30X30X45cm) at corner and every three mtr including painting with one coat of primer and two coat of enamel paint work will be done as per direction of engineer incharge of sizecomplete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 129 SITC of IP-42 and general construction confirming to IS:8623 : 1993, wall/ free standing floor mounted dust and vermin proof compartmentalisedcubical panel as specifications andOther parameters requiredas per point (a) ,(b), (c),(d), (e), (f), (g), (h) as below:- 130 (a)Thickness of CRCA sheet shallbe 2.0 mm,cable alley compartments having concealed hinged type doors with key type lock with / withoutdetachable extension type structure. Removable 3 mm. thick sheet steel gland plates with appropriate size of knockouts for cables shall be provided 131 (b)complete panel shall undergo a process of degreasing, Water rinsing, Activation, derusting,pickling in acid bath, phosphatising & shall be subjected to nine tank process and then Powder coated with approved shade of minimum 70 microns on both side of panel.The panel having PE foam/ Neoprene rubber gasket of not less than 3mm thickness ,required hardware , concealed hinged door with key type locking arrangement for equipment/switchgear earthed with 2.5 sq.mm braided copper wire. 132 [c)Interconnection between bus bar and switchgears /cable shall be rigidly supported and made out by flexible copper wires (up to 63 amp ) and by solid bus bar(>63 amp ) . control wiring will be carried out with 1.5 Sq.mm, Earth wire with 2.5 Sq.mm and CT with 2.5 sq.mm flexible copper wire only.All joints / interconnections of copper bus bar shall be dully tinned . Clearance between main bus bar and risers / metal parts shall be at least 10 mm additional to width of bus bar Bus bar is insulated by Heat Shrinkable sleeves . Earth and Neutral bus bar shall be half of the size of phase bus bar. ( Cost of Bus bar/ Flexible wire for Interconnection between Main busbar and Switchgearis to be Paid Extra ) 133 (d)Wiring between components within switchgear and Incoming / outgoing cableshall be done through the terminal block only. Direct connection shall not be permitted. Each terminal block shall be one piece moulded, barrier type, 650 volt grade, complete with washers, heads, studs with two nuts and identification strips and shall have adequate continuous current rating. For tap-offs, adjacent terminals with shorting strips shall be used. 10% Spare terminal blocks shall be provided. Wire identification on marking strip shall correspond to the designation of the wiring diagrams. All wire terminals on the equipment shall also be marked with designation corresponding to those of the wiring diagram. 134 (e)All wiring shall be enclosed in plastic channels and neatly bunched and closed in metering chamber, Wiring between terminals of various devices shall be ‘point to point’ (no wire splitting or tee connections) with wires neatly trucked along the back of the panels, adequately supported to prevent sagging. 135 (f)Floor mounted panel shall be mounted on Base frame of ISMCchannel size 100 x 50 x 5 mm( to be paid Extra ) 136 (g) Tests: The insulation resistance (with 1000 V Megger) and High voltage Power frequency test (by applying a voltage of 2.5KV for one minute) shall be measured between phases, between phase and neutral and between phase and earth. both before and after high voltage power frequency test. The insulation resistance shall not be less than three megaohm. CT Secondary current injection test shall also be carried out. 137 (h) only outer surface area on all sides shall be measured & panel to be fabricated only from CPRI approved fabricator only (CPRI Test certificates to be submitted)All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 138 Providing & Fixing of BIS approvedCurrent Transformeras per PWD specification for electrical Works ,ISI marked as perIS 2705-1992/ conforming to IEC 60044-1, with secondary terminalof CT shall be brought out suitable to a terminal block which shall be easier accessible for testing and terminal connection , with all necessary support in existing panel including connection etc. as requiredCurrent transformer Ring Type Tape Wound/Resin Cast Wound as per IS 16227 with, Accuracy Cl, CT ratio and burden as specified. ISF<=5, Cu cross section of secondary wire 1.5sqmm (minimum), including all necessary support in existing panel including connection etc. as required . All as per pre approved by Engineer in charge.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 139 Ring type tape wound CT 140 C T Class 1, Ratio 200/5 to 300/5, Burden 10 VA 141 Providing & Fixing of110/220 V, unibody LED Indicatinglamp IEC 60947with integral circuit, IP 65 above panel &IP 20 terminal block, Approx. body dia for panel not less then 20 mm, length min. 50mm, front LED cover dia min.29 mm, contact material phospher bronze for Led, PCB contacts shall be ofbrass (tin plated), impulsedielectric tested for 2.5 KV, Rated insulation resistance shall be 100 M ohm at 500VDCincluding connection etc. as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 142 Red/yellow/Green colour 143 Supplying and fixing of Aluminium (IEC 60105 ISO 209-1,2) / Copper (IEC 60028) bus bar by means of SMC / DMC type insulatorwith standard short circuit withstand capacity, high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable PVC sleeves. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 144 Electrolytic grade Aluminium bus bar 6010 grade
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
42.
Health and Family Welfare #10187085 Price Bid
Tender For Electrification Work In Bphu And Bphl At Chc Manihari Block Pali District Pali - 1 (Electrical BSR 2022 Rajasthan) Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)inrecessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit & itsISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thickHot Dipped Galvanized Modular Box with earth terminal, 10A Modular switch,Modular face plate with grid plate, 3 pin ceiling rose / Holder /3 way connector, screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR. Short point (up to 3 mtr.) 2 Short point (up to 3 mtr.) 3 Medium point (up to 6 mtr.) 4 Long point(up to 10 mtr.) 5 Wiring of twin control light point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)in recessed ISI markedMMS ( IS:9537 P - III ) PVC conduit & its ISI marked (IS:3419-1988) accessories, round tiles, 2 Nos Hot Dipped Galvanized M.S Modularbox of 1.2 mm thickwith earth terminal,2 Nos10 A two way Modular switch, 3 pin ceiling rose / holder / 3 way connector ,Modular face plate with grid plate,screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR 6 Medium point (up to 6 mtr.) 7 Long point(up to 10 mtr.) 8 Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal sizeFR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) inrecessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & its ISI marked (IS:3419-1988)accessories, Hot Dipped GalvanizedModular box of 1.2 mm thick with earth terminal, 10 A modularswitch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR 9 On board 10 S&F following sizes (dia.) of ISI marked virgin material MMS ( IS:9537 P - III ) PVC conduit along withISI marked (IS:3419-1988) accessories as requiredinrecessincludingcutting the wall, covering conduit and making good the same as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 11 20 mm 12 25 mm 13 32 mm 14 Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 forlower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5,in existingsurface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure A attached with this BSR 15 2 x 2.5 sq. mm. + 1x1.5sqmm 16 1 x 4.0 sq.mm 17 2 x 4.0 sq. mm. + 1 x 2.5 sq. mm. 18 4 x 6.0 sq.mm 19 4 x 10.0 sq.mm 20 P & F 1.2 mm thickG. I. / M .S. Sheet boxes duly finished with two coats of red oxide and with earthing terminal of following sizes (nominal size) in recessed/surface as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 21 1.2 mm thickG Iboxes 22 100mm x 100mm x 60mm 23 P & F paper phenolic resin bondedlaminates confirming to IS : 2036 -1995 for boxes/ frames including making holes for switches etc, with brass screws, washers/ zinc platednut and bolts as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 24 3.0 mm thick 25 P & F phenolic laminated sheet 2.0 mm thick of following size . Including screws, cup washer as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 26 75 mm dia 27 P & F 1.2mm thickM.S. Recessed fan box, hexagonal/ round of size 130 mm dia, depth 75mm,12 mm dia rod fan hook with 100 mmlength extended on each side . All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure A attached with this BSR 28 Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load andsite requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting ofclass 3 as per IEC,minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted inexisting distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above ratingincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 29 Single pole MCB (With B/C curve tripping Characteristics) 30 6 A to 32 A rating 31 Four pole MCB (With B/C curve tripping Characteristics) 32 50/63 A rating 33 Providing & Fixing of Recessed/surface mounting heavy duty horizontal type Double Door ( Metal / Glazed )Distribution board with Metal end box made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3, powder painted complete with reversible door (for double door DB only )100 amp. insulated copper bus bar/shorting link , copper neutral link, copper earth link , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, Ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 34 Metal door (Three phase) IK-09 and IP-43with Metal end box 35 8 Way 36 Providing & Fixing of Recessed/surface mounting heavy duty Vertical TPN Distribution board with Metal end box with provision of incomer suitable for 3/4 pole MCCB and SP / TP MCB as outgoing ,made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3. powder painted with reversible door (for double door DB only ) complete with insulated 160 (upto 160 A Incomer) / 250 Amp. copper bus bar, neutral bars with shrouds, earth bar , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure A attached with this BSR 37 Double door IP-43 & IK-09 with Provision of Incomer MCCB 100/ 125 A Rating with Metal end box 38 4 Way 39 Providing & Fixing ofISI marked (IS:371) 6 amp surface type 3 pin ceiling rose with CM/L no. printed and made out from industrial grade Polycarbonate or fire resistant ABS material, brass terminal & captive screws including making connection testing etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 40 Providing & Fixing of ISI marked (IS:1258) batten/angle lampholder with CM/L no. printed and made out from industrial grade Polycarbonate or fire resistant ABS material, brass terminal & captive screwsincluding making connection testing etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 41 P & F of Industrial plug and socket conforming to IEC 60309-1/2 made out of self extinguishing engineering polymer / polyamide, nickel plated brass sleeve and pins, socket with shutter including making connection etc as reqd. For additional technical parameters of product / work refer Annexure A attached with this BSR 42 IP -67 Surface/Wall mounted socket 43 32 A 3 pin(2P+E) 44 Providing & Fixing of modular type 120 W Step Fan regulator duly ISI marked (IS 11037:1984 ) with CM/L no. printedmade out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating ,includingall as per pre approved by Engineer in charge,making connections, testing etc. as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 45 5 step fan regulator 2 Module 360 dgree rotating 46 SITC of3 /4pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant materialhaving following current rating, short circuitbreaking capacityat 440/415 V, 50 Hz; O/L & S/C settings , conforming to IS/IEC 60947 P -2 :2003 with frontface and centralised adjustable, trip free mechanisum, true contact position indicator,line load interchangeability,designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree,pollution degree 3, having positive isolation capability, push(test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% Icu. U imp =8 KV, rated insulation voltage690 V.provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connectionsetc. as required.OEM shall have submitNABL / CPRI / ERDA accrediated lab type test certificate before execution All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 47 4 pole MCCB With Thermal Magnetic release 48 125 Amp , 25 kA, adjustable O/L & adjustable S/C setting, 49 Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed ArrmouredAluminiumcable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV withH4- Grade electrolyticaluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) includingtesting etc. as required of following size. OEM must have its own in house NABL accrediated Laboratory for testing procedure as per IS:10810.For additional technical parameters of product / work refer Annexure A attached with this BSR 50 50.0 Sq. mm 51 3.5 core 52 Supplyandinstallationofhigh tensile low carbon steel rod molecularly bonded with 99.9 % Copperthickness (250 microns) andconfirming toUL 467, IS/IEC 62561-2of following size and length and as per point mentioned (a), (b), [c), (d), (e) below :- 53 (a) Bore a hole of dia. 100 mm of required length, Place the rod in the centre of Hole 54 (b)filled with anti corrosiveconductivecompounds with the permanent sealings at both the ends, CPRI/ ERDAtested with RMS capacity of minimum 30 KA for withstanding 1 second .To ensure the moisture content and electrical conductivity, 25 kg for 2000 mm & 50 Kgs for 3000mm of resistance lowering earth enhancement material shall be used as a backfill compound. The compound shall be tested form NABL acredeated labfor lowresistivity ( less than 0.12 Ohm - meter ) & high conductivity in nature with carbon as a major contentas per referance of IS 3043-1987,IEEE 80-2013 (clause 14.5d) , IEEE 837 & IER 1956 with latest amendemnts 55 © Connect the rod with copper Strip/Conductor/Wire with suitable clamp made from tinned copper and SS 304 Bolt 56 (d) Place Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height250 to 300 mm. 57 (d)Testing of earth resistance for value of 5 ohms or lessas required & must record by engineer in charge during site visit and ensure to enter in measurment book. 58 (e) Test certificatesfor confirming above standards from OEM is mandatory. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 59 17.2 mm thick and 3 Mtr. Long 60 Supply & Laying following size earth stripin horizontal or vertical run in surface by means of Earth strip DMC Insulatorincluding riveting/ soldering/ welding, Jointing shall be done by overlapping and with 2 set of Brass (for Cu strip) / GI (for GI Strip) nut bolt & spring washer spaced at 50cm making connection etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 61 25mm x 3mm Alum. Strip 62 Providing & Fixing ofBEEStar rated copper wounded double ball bearing capacitor start, aluminium body & Metallicblade ceilingfanConforming to all the performance requirements laid down in IS 374:2019 including all amendments, as applicable ; & Carry BIS licensing (i.e. ISI marking) with down rod up to 80 cm with secondary support safety cable ( steel rope) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 63 1200 mm Sweep BEE 2 Star rated (service value >=4.5 to < 5 ) 64 Providing & Fixing of Heavy duty capacitor start, copper woundDouble ball bearing900/1400 RPM single phaseExhaustfan conforming to IS:2312 ISI marked in existing opening including making connections testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 65 300 mm sweep(900/1400 RPM) 66 380 mm sweep(900/1400 RPM) 67 P & F of Gravity Louver shutter of superior quality made out of frame of18 swg M.S. sheet & Louvers made from 24 swg MS Sheetwith enamel paint including cost of nuts, bolts, etc as reqd.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 68 Up to 380 mm size 69 Providing & Fixing of energy efficient direct fit (Retrofit)Polycarbonate/ GlasshousingSMD Mid Power LED tube rod(with integral driver & alumn. heat sink ), on existing fixture.system lumen efficacy ≥ 100 lm/Watt output, internal surge protection of 2.5 KV ,THD < 20% ,p.f.≥0.95,CRI >80 , life time of minimum35000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80)certificate / Report from OEM shall be submitted.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 70 1200mm , Min. Lumens output 2000 lmLED Tube rod with Polycarbonate Housing 71 Providing & Fixing of IP-20 LED Recessed / Surface Mounted, Round / SqaureSMD Mid Power LED Downlight with power coated die-cast aluminum housingwith UV Stabilized non yellowish Diffuser withBIS complience 2.5 KV surge protected Isolated driver, with Short & Open circuit protection, having efficiency > 85% . System Lumen efficacy of ≥ 110 lm / watt, THD < 10 % , Pf.≥0.95, CRI >80,life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. 72 OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 73 Surface Mounting (with extruded alumn. Housing ) 74 Minimum lumen output 2400 lm 75 Providing & Fixing of IK08, IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminummaterial with heat dissipation fins on housing with UV stabilized PC (UV stablization report submitted for UV cover ) /Toughened Glass coverand secondary lens on each LED & should be SMD type of 3 to 5 watt each . The System efficacy >=125 lm/ wt and potted driver& has a unique BIS R number withInput Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety , Power Factor >0.95 driverEfficiency >85%,THD(I) <10%Humidity 10% to 90% RH Working Temp -5C to 45C .driver current <750mA. The luminaireshall be BIS certified and Trade mark certified. Life ExpectancyEqual or more than 50000 burning hrs with Minimum 70% lumen maintened , CRI >70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external inside driver compartment. driver should be Phase to phase protection of 440 V for 4 Hrs.Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities forLED fixtures.(LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 76 LED Street Light fixture with Minimum lumen output 8700 lm 77 Providing & Fixing of Street light bracket made out from following size of B class , Medium class G.I. Pipe confirming to IS : 1239 P - 1 ( 2004 ) with heavy duty pole clamp, Saddles suitable fastners etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 78 32 mm Dia. 79 Supply, Drawing and Testing of 4 pair, 23 AWG Solid Bare Copper wire insulated with PVC, UTP (Unshielded Twisted Pair), Category 6, Class E, 100 Ohm Impedance, Indoor Cable as per latest ammendments of ANSI/TIA/EIA-568 , The copper conductors should be balanced twisted in pairs, seperated by a cross-member fluted pair divider & protected byPVC Jacket. Certified performance in a 4-connector configuration upto 100 Mtrs channel requirements & transmission frequencies up to 250 Mhz. in existing MS/PVC Conduits/casing capping including making connections to Information outlets and Patch Panels with jack &ferruling at both ends for identification with necessary tools for punching, stripping, crimping and testing etc as required complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 80 Supply and Installation of unsheilded/360 degree sheilded Information outlets made of high impact plastic body with ABS, FR Grade halogen free material with provision for protection against dust in jack, suitable for Cat 6/6A application complying to latest ammendments, According. to Cat. 6/6A channel, It should support channel as well as components requirements of Cat.6/6A standards at frequencies of up to 250 to 500 Mhz. Cat 6/6A unshielded/shielded Jack should be suitable to terminate 4 pair, 23/24 AWG solid/stranded wire diameters, using 100 Ohm unshielded/shielded balance twisted pair cable, the jack should have tooless/impact termination on reliable copper tin plated Insulation displacement contact, with easy lock mechanism, It supports IEC 60603-7-4 and complied with ANSI/TIA/EIA 568 C.2 standard. jack should be RJ11,RJ12 & RJ45 compatible. Should support Ethernet 1.2 Gb/s ATM,Digital video and broadband/baseband analog video, Voice over internet protocal (VOIP) Specifications in existing modular/MS Boxes along with necessory connections as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 81 Cat 6, Un-sheilded Information Outlet 82 Supply & fixing of square Faceplate for Flush / Surface Mount Information Outlets Single/Dual or Quad Aperture ,material should bePC+ABS body, Suitable for RJ45 unshielded/shielded connection modules. Should match with I. O. OEM. Dimensions should be 86mm X 86mm as required complete in all respect.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 83 Single Aperture 84 Supply , Installation and Testing of 4 pair, 100 Ohm impedance, Cat 6/6A /Class E/Ea patch cords should be constructed of minimum 23/24 AWG, stranded bare Copper cable with FRPVC/LSZH Jacket, with an enhanced performance by factory moulded RJ45 connectors with strain relief boots as per ANSI/TIA/EIA 568-C.2 suitable for Cat 6/6A application complying to latest ammendments Category 6/6A Standards, According. to TIA568C.2, ISO/IEC 11801, EN 50173, IEC 60603-7-51, EN 60603-7, IEEE 802.3an minimum requirement for 1G BASE-T to 10G BASE-T performance. Patch cords shall be straight thru cable compatible with both T568-A and T568-B wiring schemes, should support IEEE 802.3af / IEEE 802.3at for POE applications, Minimum 750 to 1000 mating cycles in plug contacts for long durability, Should support Ethernet 10GBASE-T, 1.2 Gb/s ATM, Token ring 4/16, Digital video and broadband/baseband analog video, Voice over internet protocal (VOIP).All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 85 Cat 6, U/UTP (Unscreened/Un-sheilded Twisted Pair) Patch Cord 86 2 Mtr 87 Supply, Installation, OTDR Testing & Fusion Splicing of Fiber Multimode Pigtail (50/125 µm) made of glass fiber optic,should be fitted at one end with any one type of single ST/E-2000/SC/LC/MT-RJ/PC type connector in acc., as per latest ammendments of TIA/EIA 569Standard Specification as per requirments complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 88 Supply, Installation, & Testing of 19 1U Rack Mounted/ surface mounted aluminum/ CRCA 1.2mm powder coated, Singlemode glass Fiber Optic Cable Patch panel/LIU loaded with flangless/screwable duplex adapters for ST/E-2000/SC/LC/MT-RJ/PC type, It should have easy removable Top plate with push buttons, there should be a splice tray installed in the Patch panel/LIU which can handle the fiber cores, splice tray should be PC+ABS material, it should include accessories like mounting hardware, gormetts, heat shrink tubes/sleevs, screws, nuts to install the panel for rack/wallmount applications as per requirment complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 89 12 Ports 90 Supply , Installation, Testing and Comissioning ofManaged Layer-2 Intelligent 10/100 Ethernet Switch providing 24 x 10/100/1000 MBPS Giga Ethernet ports / with min 2 SFP Giga Ports (provision for Fiber Giga connectivity) with related LAN Base Software including making connections etc as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 91 Supply , Installation, Testing and Comissioning ofInverter type Air Cooled Hi Wall split type Air conditioners with latest star rating system as per BEE amended upto date complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU), R-32/R-410 Green Refrigerant, wireless Remote control, suitable for working between 230V +/- 10% with low & high voltage cutoff and50 hz , single phaseACsupply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 92 1.5 TR ISEER not less then 3.8 93 Supply, Fixing and testing of following capacity ISO certified company made wall mounted stabilizer having output voltage variation from 200 V to 250 V(+/-5%) with input voltage variation from 170 V to 260 V, time delay facility from 2 to 4 minute and high cutoff at 270 V with providing of 16 Amp /20 Amp Industrialplug top making connection etc complete in all respect.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 94 4 kVA 95 Making hole in stone masonary/ RCC wall/ RCC slab with core cutter for accomodating refrigerant pipe/ drain pipe/ MS pipe/ cables etc of following dia 96 100 mm dia per running inch length 97 Providing & Fixing of IS : 4985 - 2000 Class -4 (10 Kgf / Sqcm) UPVC drain water piping withfittings (IS:7834 & 10Kgf/sqcm) like elbow, socket, Tee, solvent cement jointing,support with MS hanger on ceiling or recessed in wallwith chasing & plastering with 6 mmthickclosedcellelastomeric nitrile rubberinsulation including leakage testing etc. as required of following Nominal sizes. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 98 20 mm 99 Supply & fixing MS powder coated stand suitable for 1.0/1.5/ 2.0 Tr outdoor type of Split AC.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 100 Supply & Fixing of Dry Powder Agent (as per IS 4308:2019), ABC typeFire Extinguisher (Stored Pressure type) conforming to IS:15683:2018 , Powder coated Internal & External Surface Deep drawn cylinder body of Mild Steel CR2 grade conforming to IS: 513, Squeeze grip Forged brass release valve with Inbuilt safety release device, Diaphragm Type, 0 to 28 bar range pressure gauge, 450 mm long EPDM discharge tube, QR code for Product Traceability including Fixing on wall with suitable Anchor Fasteners as required of following capacity. Test Certificates of all the Parameters along with Hydro test & Burst test (For Cylinder Body) Certificatefrom OEM / External NABL Accrediated Lab is to be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 101 4 kg
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 4
43.
Health and Family Welfare #10187079 Price Bid
Tender For Electrification Work In Bphu And Bphl At Chc Sadri Block Desuri District Pali - 1 (Electrical BSR 2022 Rajasthan) Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)inrecessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit & itsISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thickHot Dipped Galvanized Modular Box with earth terminal, 10A Modular switch,Modular face plate with grid plate, 3 pin ceiling rose / Holder /3 way connector, screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR. Short point (up to 3 mtr.) 2 Short point (up to 3 mtr.) 3 Medium point (up to 6 mtr.) 4 Long point(up to 10 mtr.) 5 Wiring of twin control light point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)in recessed ISI markedMMS ( IS:9537 P - III ) PVC conduit & its ISI marked (IS:3419-1988) accessories, round tiles, 2 Nos Hot Dipped Galvanized M.S Modularbox of 1.2 mm thickwith earth terminal,2 Nos10 A two way Modular switch, 3 pin ceiling rose / holder / 3 way connector ,Modular face plate with grid plate,screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR 6 Medium point (up to 6 mtr.) 7 Long point(up to 10 mtr.) 8 Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal sizeFR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) inrecessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & its ISI marked (IS:3419-1988)accessories, Hot Dipped GalvanizedModular box of 1.2 mm thick with earth terminal, 10 A modularswitch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR 9 On board 10 S&F following sizes (dia.) of ISI marked virgin material MMS ( IS:9537 P - III ) PVC conduit along withISI marked (IS:3419-1988) accessories as requiredinrecessincludingcutting the wall, covering conduit and making good the same as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 11 20 mm 12 25 mm 13 32 mm 14 Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 forlower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5,in existingsurface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure A attached with this BSR 15 2 x 2.5 sq. mm. + 1x1.5sqmm 16 1 x 4.0 sq.mm 17 2 x 4.0 sq. mm. + 1 x 2.5 sq. mm. 18 4 x 6.0 sq.mm 19 4 x 10.0 sq.mm 20 P & F 1.2 mm thickG. I. / M .S. Sheet boxes duly finished with two coats of red oxide and with earthing terminal of following sizes (nominal size) in recessed/surface as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 21 1.2 mm thickG Iboxes 22 100mm x 100mm x 60mm 23 P & F paper phenolic resin bondedlaminates confirming to IS : 2036 -1995 for boxes/ frames including making holes for switches etc, with brass screws, washers/ zinc platednut and bolts as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 24 3.0 mm thick 25 P & F phenolic laminated sheet 2.0 mm thick of following size . Including screws, cup washer as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 26 75 mm dia 27 P & F 1.2mm thickM.S. Recessed fan box, hexagonal/ round of size 130 mm dia, depth 75mm,12 mm dia rod fan hook with 100 mmlength extended on each side . All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure A attached with this BSR 28 Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load andsite requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting ofclass 3 as per IEC,minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted inexisting distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above ratingincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 29 Single pole MCB (With B/C curve tripping Characteristics) 30 6 A to 32 A rating 31 Four pole MCB (With B/C curve tripping Characteristics) 32 50/63 A rating 33 Providing & Fixing of Recessed/surface mounting heavy duty horizontal type Double Door ( Metal / Glazed )Distribution board with Metal end box made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3, powder painted complete with reversible door (for double door DB only )100 amp. insulated copper bus bar/shorting link , copper neutral link, copper earth link , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, Ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 34 Metal door (Three phase) IK-09 and IP-43with Metal end box 35 8 Way 36 Providing & Fixing of Recessed/surface mounting heavy duty Vertical TPN Distribution board with Metal end box with provision of incomer suitable for 3/4 pole MCCB and SP / TP MCB as outgoing ,made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3. powder painted with reversible door (for double door DB only ) complete with insulated 160 (upto 160 A Incomer) / 250 Amp. copper bus bar, neutral bars with shrouds, earth bar , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure A attached with this BSR 37 Double door IP-43 & IK-09 with Provision of Incomer MCCB 100/ 125 A Rating with Metal end box 38 4 Way 39 Providing & Fixing ofISI marked (IS:371) 6 amp surface type 3 pin ceiling rose with CM/L no. printed and made out from industrial grade Polycarbonate or fire resistant ABS material, brass terminal & captive screws including making connection testing etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 40 Providing & Fixing of ISI marked (IS:1258) batten/angle lampholder with CM/L no. printed and made out from industrial grade Polycarbonate or fire resistant ABS material, brass terminal & captive screwsincluding making connection testing etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 41 P & F of Industrial plug and socket conforming to IEC 60309-1/2 made out of self extinguishing engineering polymer / polyamide, nickel plated brass sleeve and pins, socket with shutter including making connection etc as reqd. For additional technical parameters of product / work refer Annexure A attached with this BSR 42 IP -67 Surface/Wall mounted socket 43 32 A 3 pin(2P+E) 44 Providing & Fixing of modular type 120 W Step Fan regulator duly ISI marked (IS 11037:1984 ) with CM/L no. printedmade out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating ,includingall as per pre approved by Engineer in charge,making connections, testing etc. as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 45 5 step fan regulator 2 Module 360 dgree rotating 46 SITC of3 /4pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant materialhaving following current rating, short circuitbreaking capacityat 440/415 V, 50 Hz; O/L & S/C settings , conforming to IS/IEC 60947 P -2 :2003 with frontface and centralised adjustable, trip free mechanisum, true contact position indicator,line load interchangeability,designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree,pollution degree 3, having positive isolation capability, push(test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% Icu. U imp =8 KV, rated insulation voltage690 V.provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connectionsetc. as required.OEM shall have submitNABL / CPRI / ERDA accrediated lab type test certificate before execution All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 47 4 pole MCCB With Thermal Magnetic release 48 125 Amp , 25 kA, adjustable O/L & adjustable S/C setting, 49 Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed ArrmouredAluminiumcable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV withH4- Grade electrolyticaluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) includingtesting etc. as required of following size. OEM must have its own in house NABL accrediated Laboratory for testing procedure as per IS:10810.For additional technical parameters of product / work refer Annexure A attached with this BSR 50 50.0 Sq. mm 51 3.5 core 52 Supplyandinstallationofhigh tensile low carbon steel rod molecularly bonded with 99.9 % Copperthickness (250 microns) andconfirming toUL 467, IS/IEC 62561-2of following size and length and as per point mentioned (a), (b), [c), (d), (e) below :- 53 (a) Bore a hole of dia. 100 mm of required length, Place the rod in the centre of Hole 54 (b)filled with anti corrosiveconductivecompounds with the permanent sealings at both the ends, CPRI/ ERDAtested with RMS capacity of minimum 30 KA for withstanding 1 second .To ensure the moisture content and electrical conductivity, 25 kg for 2000 mm & 50 Kgs for 3000mm of resistance lowering earth enhancement material shall be used as a backfill compound. The compound shall be tested form NABL acredeated labfor lowresistivity ( less than 0.12 Ohm - meter ) & high conductivity in nature with carbon as a major contentas per referance of IS 3043-1987,IEEE 80-2013 (clause 14.5d) , IEEE 837 & IER 1956 with latest amendemnts 55 © Connect the rod with copper Strip/Conductor/Wire with suitable clamp made from tinned copper and SS 304 Bolt 56 (d) Place Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height250 to 300 mm. 57 (d)Testing of earth resistance for value of 5 ohms or lessas required & must record by engineer in charge during site visit and ensure to enter in measurment book. 58 (e) Test certificatesfor confirming above standards from OEM is mandatory. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 59 17.2 mm thick and 3 Mtr. Long 60 Supply & Laying following size earth stripin horizontal or vertical run in surface by means of Earth strip DMC Insulatorincluding riveting/ soldering/ welding, Jointing shall be done by overlapping and with 2 set of Brass (for Cu strip) / GI (for GI Strip) nut bolt & spring washer spaced at 50cm making connection etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 61 25mm x 3mm Alum. Strip 62 Providing & Fixing ofBEEStar rated copper wounded double ball bearing capacitor start, aluminium body & Metallicblade ceilingfanConforming to all the performance requirements laid down in IS 374:2019 including all amendments, as applicable ; & Carry BIS licensing (i.e. ISI marking) with down rod up to 80 cm with secondary support safety cable ( steel rope) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 63 1200 mm Sweep BEE 2 Star rated (service value >=4.5 to < 5 ) 64 Providing & Fixing of Heavy duty capacitor start, copper woundDouble ball bearing900/1400 RPM single phaseExhaustfan conforming to IS:2312 ISI marked in existing opening including making connections testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 65 300 mm sweep(900/1400 RPM) 66 380 mm sweep(900/1400 RPM) 67 P & F of Gravity Louver shutter of superior quality made out of frame of18 swg M.S. sheet & Louvers made from 24 swg MS Sheetwith enamel paint including cost of nuts, bolts, etc as reqd.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 68 Up to 380 mm size 69 Providing & Fixing of energy efficient direct fit (Retrofit)Polycarbonate/ GlasshousingSMD Mid Power LED tube rod(with integral driver & alumn. heat sink ), on existing fixture.system lumen efficacy ≥ 100 lm/Watt output, internal surge protection of 2.5 KV ,THD < 20% ,p.f.≥0.95,CRI >80 , life time of minimum35000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80)certificate / Report from OEM shall be submitted.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 70 1200mm , Min. Lumens output 2000 lmLED Tube rod with Polycarbonate Housing 71 Providing & Fixing of IP-20 LED Recessed / Surface Mounted, Round / SqaureSMD Mid Power LED Downlight with power coated die-cast aluminum housingwith UV Stabilized non yellowish Diffuser withBIS complience 2.5 KV surge protected Isolated driver, with Short & Open circuit protection, having efficiency > 85% . System Lumen efficacy of ≥ 110 lm / watt, THD < 10 % , Pf.≥0.95, CRI >80,life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. 72 OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 73 Surface Mounting (with extruded alumn. Housing ) 74 Minimum lumen output 2400 lm 75 Providing & Fixing of IK08, IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminummaterial with heat dissipation fins on housing with UV stabilized PC (UV stablization report submitted for UV cover ) /Toughened Glass coverand secondary lens on each LED & should be SMD type of 3 to 5 watt each . The System efficacy >=125 lm/ wt and potted driver& has a unique BIS R number withInput Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety , Power Factor >0.95 driverEfficiency >85%,THD(I) <10%Humidity 10% to 90% RH Working Temp -5C to 45C .driver current <750mA. The luminaireshall be BIS certified and Trade mark certified. Life ExpectancyEqual or more than 50000 burning hrs with Minimum 70% lumen maintened , CRI >70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external inside driver compartment. driver should be Phase to phase protection of 440 V for 4 Hrs.Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities forLED fixtures.(LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 76 LED Street Light fixture with Minimum lumen output 8700 lm 77 Providing & Fixing of Street light bracket made out from following size of B class , Medium class G.I. Pipe confirming to IS : 1239 P - 1 ( 2004 ) with heavy duty pole clamp, Saddles suitable fastners etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 78 32 mm Dia. 79 Supply, Drawing and Testing of 4 pair, 23 AWG Solid Bare Copper wire insulated with PVC, UTP (Unshielded Twisted Pair), Category 6, Class E, 100 Ohm Impedance, Indoor Cable as per latest ammendments of ANSI/TIA/EIA-568 , The copper conductors should be balanced twisted in pairs, seperated by a cross-member fluted pair divider & protected byPVC Jacket. Certified performance in a 4-connector configuration upto 100 Mtrs channel requirements & transmission frequencies up to 250 Mhz. in existing MS/PVC Conduits/casing capping including making connections to Information outlets and Patch Panels with jack &ferruling at both ends for identification with necessary tools for punching, stripping, crimping and testing etc as required complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 80 Supply and Installation of unsheilded/360 degree sheilded Information outlets made of high impact plastic body with ABS, FR Grade halogen free material with provision for protection against dust in jack, suitable for Cat 6/6A application complying to latest ammendments, According. to Cat. 6/6A channel, It should support channel as well as components requirements of Cat.6/6A standards at frequencies of up to 250 to 500 Mhz. Cat 6/6A unshielded/shielded Jack should be suitable to terminate 4 pair, 23/24 AWG solid/stranded wire diameters, using 100 Ohm unshielded/shielded balance twisted pair cable, the jack should have tooless/impact termination on reliable copper tin plated Insulation displacement contact, with easy lock mechanism, It supports IEC 60603-7-4 and complied with ANSI/TIA/EIA 568 C.2 standard. jack should be RJ11,RJ12 & RJ45 compatible. Should support Ethernet 1.2 Gb/s ATM,Digital video and broadband/baseband analog video, Voice over internet protocal (VOIP) Specifications in existing modular/MS Boxes along with necessory connections as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 81 Cat 6, Un-sheilded Information Outlet 82 Supply & fixing of square Faceplate for Flush / Surface Mount Information Outlets Single/Dual or Quad Aperture ,material should bePC+ABS body, Suitable for RJ45 unshielded/shielded connection modules. Should match with I. O. OEM. Dimensions should be 86mm X 86mm as required complete in all respect.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 83 Single Aperture 84 Supply , Installation and Testing of 4 pair, 100 Ohm impedance, Cat 6/6A /Class E/Ea patch cords should be constructed of minimum 23/24 AWG, stranded bare Copper cable with FRPVC/LSZH Jacket, with an enhanced performance by factory moulded RJ45 connectors with strain relief boots as per ANSI/TIA/EIA 568-C.2 suitable for Cat 6/6A application complying to latest ammendments Category 6/6A Standards, According. to TIA568C.2, ISO/IEC 11801, EN 50173, IEC 60603-7-51, EN 60603-7, IEEE 802.3an minimum requirement for 1G BASE-T to 10G BASE-T performance. Patch cords shall be straight thru cable compatible with both T568-A and T568-B wiring schemes, should support IEEE 802.3af / IEEE 802.3at for POE applications, Minimum 750 to 1000 mating cycles in plug contacts for long durability, Should support Ethernet 10GBASE-T, 1.2 Gb/s ATM, Token ring 4/16, Digital video and broadband/baseband analog video, Voice over internet protocal (VOIP).All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 85 Cat 6, U/UTP (Unscreened/Un-sheilded Twisted Pair) Patch Cord 86 2 Mtr 87 Supply, Installation, OTDR Testing & Fusion Splicing of Fiber Multimode Pigtail (50/125 µm) made of glass fiber optic,should be fitted at one end with any one type of single ST/E-2000/SC/LC/MT-RJ/PC type connector in acc., as per latest ammendments of TIA/EIA 569Standard Specification as per requirments complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 88 Supply, Installation, & Testing of 19 1U Rack Mounted/ surface mounted aluminum/ CRCA 1.2mm powder coated, Singlemode glass Fiber Optic Cable Patch panel/LIU loaded with flangless/screwable duplex adapters for ST/E-2000/SC/LC/MT-RJ/PC type, It should have easy removable Top plate with push buttons, there should be a splice tray installed in the Patch panel/LIU which can handle the fiber cores, splice tray should be PC+ABS material, it should include accessories like mounting hardware, gormetts, heat shrink tubes/sleevs, screws, nuts to install the panel for rack/wallmount applications as per requirment complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 89 12 Ports 90 Supply , Installation, Testing and Comissioning ofManaged Layer-2 Intelligent 10/100 Ethernet Switch providing 24 x 10/100/1000 MBPS Giga Ethernet ports / with min 2 SFP Giga Ports (provision for Fiber Giga connectivity) with related LAN Base Software including making connections etc as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 91 Supply , Installation, Testing and Comissioning ofInverter type Air Cooled Hi Wall split type Air conditioners with latest star rating system as per BEE amended upto date complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU), R-32/R-410 Green Refrigerant, wireless Remote control, suitable for working between 230V +/- 10% with low & high voltage cutoff and50 hz , single phaseACsupply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 92 1.5 TR ISEER not less then 3.8 93 Supply, Fixing and testing of following capacity ISO certified company made wall mounted stabilizer having output voltage variation from 200 V to 250 V(+/-5%) with input voltage variation from 170 V to 260 V, time delay facility from 2 to 4 minute and high cutoff at 270 V with providing of 16 Amp /20 Amp Industrialplug top making connection etc complete in all respect.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 94 4 kVA 95 Making hole in stone masonary/ RCC wall/ RCC slab with core cutter for accomodating refrigerant pipe/ drain pipe/ MS pipe/ cables etc of following dia 96 100 mm dia per running inch length 97 Providing & Fixing of IS : 4985 - 2000 Class -4 (10 Kgf / Sqcm) UPVC drain water piping withfittings (IS:7834 & 10Kgf/sqcm) like elbow, socket, Tee, solvent cement jointing,support with MS hanger on ceiling or recessed in wallwith chasing & plastering with 6 mmthickclosedcellelastomeric nitrile rubberinsulation including leakage testing etc. as required of following Nominal sizes. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 98 20 mm 99 Supply & fixing MS powder coated stand suitable for 1.0/1.5/ 2.0 Tr outdoor type of Split AC.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 100 Supply & Fixing of Dry Powder Agent (as per IS 4308:2019), ABC typeFire Extinguisher (Stored Pressure type) conforming to IS:15683:2018 , Powder coated Internal & External Surface Deep drawn cylinder body of Mild Steel CR2 grade conforming to IS: 513, Squeeze grip Forged brass release valve with Inbuilt safety release device, Diaphragm Type, 0 to 28 bar range pressure gauge, 450 mm long EPDM discharge tube, QR code for Product Traceability including Fixing on wall with suitable Anchor Fasteners as required of following capacity. Test Certificates of all the Parameters along with Hydro test & Burst test (For Cylinder Body) Certificatefrom OEM / External NABL Accrediated Lab is to be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 101 4 kg
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 5
44.
Health and Family Welfare #10187077 Price Bid
Tender For Electrification Work In Bphu And Bphl At Chc Takhatgarh Block Sumerpur District Pali - 1 (Electrical BSR 2022 Rajasthan) Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)inrecessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit & itsISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thickHot Dipped Galvanized Modular Box with earth terminal, 10A Modular switch,Modular face plate with grid plate, 3 pin ceiling rose / Holder /3 way connector, screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR. Short point (up to 3 mtr.) 2 Short point (up to 3 mtr.) 3 Medium point (up to 6 mtr.) 4 Long point(up to 10 mtr.) 5 Wiring of twin control light point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)in recessed ISI markedMMS ( IS:9537 P - III ) PVC conduit & its ISI marked (IS:3419-1988) accessories, round tiles, 2 Nos Hot Dipped Galvanized M.S Modularbox of 1.2 mm thickwith earth terminal,2 Nos10 A two way Modular switch, 3 pin ceiling rose / holder / 3 way connector ,Modular face plate with grid plate,screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR 6 Medium point (up to 6 mtr.) 7 Long point(up to 10 mtr.) 8 Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal sizeFR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) inrecessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & its ISI marked (IS:3419-1988)accessories, Hot Dipped GalvanizedModular box of 1.2 mm thick with earth terminal, 10 A modularswitch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR 9 On board 10 S&F following sizes (dia.) of ISI marked virgin material MMS ( IS:9537 P - III ) PVC conduit along withISI marked (IS:3419-1988) accessories as requiredinrecessincludingcutting the wall, covering conduit and making good the same as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 11 20 mm 12 25 mm 13 32 mm 14 Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 forlower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5,in existingsurface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure A attached with this BSR 15 2 x 2.5 sq. mm. + 1x1.5sqmm 16 1 x 4.0 sq.mm 17 2 x 4.0 sq. mm. + 1 x 2.5 sq. mm. 18 4 x 6.0 sq.mm 19 4 x 10.0 sq.mm 20 P & F 1.2 mm thickG. I. / M .S. Sheet boxes duly finished with two coats of red oxide and with earthing terminal of following sizes (nominal size) in recessed/surface as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 21 1.2 mm thickG Iboxes 22 100mm x 100mm x 60mm 23 P & F paper phenolic resin bondedlaminates confirming to IS : 2036 -1995 for boxes/ frames including making holes for switches etc, with brass screws, washers/ zinc platednut and bolts as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 24 3.0 mm thick 25 P & F phenolic laminated sheet 2.0 mm thick of following size . Including screws, cup washer as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 26 75 mm dia 27 P & F 1.2mm thickM.S. Recessed fan box, hexagonal/ round of size 130 mm dia, depth 75mm,12 mm dia rod fan hook with 100 mmlength extended on each side . All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure A attached with this BSR 28 Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load andsite requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting ofclass 3 as per IEC,minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted inexisting distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above ratingincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 29 Single pole MCB (With B/C curve tripping Characteristics) 30 6 A to 32 A rating 31 Four pole MCB (With B/C curve tripping Characteristics) 32 50/63 A rating 33 Providing & Fixing of Recessed/surface mounting heavy duty horizontal type Double Door ( Metal / Glazed )Distribution board with Metal end box made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3, powder painted complete with reversible door (for double door DB only )100 amp. insulated copper bus bar/shorting link , copper neutral link, copper earth link , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, Ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 34 Metal door (Three phase) IK-09 and IP-43with Metal end box 35 8 Way 36 Providing & Fixing of Recessed/surface mounting heavy duty Vertical TPN Distribution board with Metal end box with provision of incomer suitable for 3/4 pole MCCB and SP / TP MCB as outgoing ,made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3. powder painted with reversible door (for double door DB only ) complete with insulated 160 (upto 160 A Incomer) / 250 Amp. copper bus bar, neutral bars with shrouds, earth bar , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure A attached with this BSR 37 Double door IP-43 & IK-09 with Provision of Incomer MCCB 100/ 125 A Rating with Metal end box 38 4 Way 39 Providing & Fixing ofISI marked (IS:371) 6 amp surface type 3 pin ceiling rose with CM/L no. printed and made out from industrial grade Polycarbonate or fire resistant ABS material, brass terminal & captive screws including making connection testing etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 40 Providing & Fixing of ISI marked (IS:1258) batten/angle lampholder with CM/L no. printed and made out from industrial grade Polycarbonate or fire resistant ABS material, brass terminal & captive screwsincluding making connection testing etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 41 P & F of Industrial plug and socket conforming to IEC 60309-1/2 made out of self extinguishing engineering polymer / polyamide, nickel plated brass sleeve and pins, socket with shutter including making connection etc as reqd. For additional technical parameters of product / work refer Annexure A attached with this BSR 42 IP -67 Surface/Wall mounted socket 43 32 A 3 pin(2P+E) 44 Providing & Fixing of modular type 120 W Step Fan regulator duly ISI marked (IS 11037:1984 ) with CM/L no. printedmade out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating ,includingall as per pre approved by Engineer in charge,making connections, testing etc. as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 45 5 step fan regulator 2 Module 360 dgree rotating 46 SITC of3 /4pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant materialhaving following current rating, short circuitbreaking capacityat 440/415 V, 50 Hz; O/L & S/C settings , conforming to IS/IEC 60947 P -2 :2003 with frontface and centralised adjustable, trip free mechanisum, true contact position indicator,line load interchangeability,designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree,pollution degree 3, having positive isolation capability, push(test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% Icu. U imp =8 KV, rated insulation voltage690 V.provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connectionsetc. as required.OEM shall have submitNABL / CPRI / ERDA accrediated lab type test certificate before execution All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 47 4 pole MCCB With Thermal Magnetic release 48 125 Amp , 25 kA, adjustable O/L & adjustable S/C setting, 49 Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed ArrmouredAluminiumcable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV withH4- Grade electrolyticaluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) includingtesting etc. as required of following size. OEM must have its own in house NABL accrediated Laboratory for testing procedure as per IS:10810.For additional technical parameters of product / work refer Annexure A attached with this BSR 50 50.0 Sq. mm 51 3.5 core 52 Supplyandinstallationofhigh tensile low carbon steel rod molecularly bonded with 99.9 % Copperthickness (250 microns) andconfirming toUL 467, IS/IEC 62561-2of following size and length and as per point mentioned (a), (b), [c), (d), (e) below :- 53 (a) Bore a hole of dia. 100 mm of required length, Place the rod in the centre of Hole 54 (b)filled with anti corrosiveconductivecompounds with the permanent sealings at both the ends, CPRI/ ERDAtested with RMS capacity of minimum 30 KA for withstanding 1 second .To ensure the moisture content and electrical conductivity, 25 kg for 2000 mm & 50 Kgs for 3000mm of resistance lowering earth enhancement material shall be used as a backfill compound. The compound shall be tested form NABL acredeated labfor lowresistivity ( less than 0.12 Ohm - meter ) & high conductivity in nature with carbon as a major contentas per referance of IS 3043-1987,IEEE 80-2013 (clause 14.5d) , IEEE 837 & IER 1956 with latest amendemnts 55 © Connect the rod with copper Strip/Conductor/Wire with suitable clamp made from tinned copper and SS 304 Bolt 56 (d) Place Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height250 to 300 mm. 57 (d)Testing of earth resistance for value of 5 ohms or lessas required & must record by engineer in charge during site visit and ensure to enter in measurment book. 58 (e) Test certificatesfor confirming above standards from OEM is mandatory. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 59 17.2 mm thick and 3 Mtr. Long 60 Supply & Laying following size earth stripin horizontal or vertical run in surface by means of Earth strip DMC Insulatorincluding riveting/ soldering/ welding, Jointing shall be done by overlapping and with 2 set of Brass (for Cu strip) / GI (for GI Strip) nut bolt & spring washer spaced at 50cm making connection etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 61 25mm x 3mm Alum. Strip 62 Providing & Fixing ofBEEStar rated copper wounded double ball bearing capacitor start, aluminium body & Metallicblade ceilingfanConforming to all the performance requirements laid down in IS 374:2019 including all amendments, as applicable ; & Carry BIS licensing (i.e. ISI marking) with down rod up to 80 cm with secondary support safety cable ( steel rope) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 63 1200 mm Sweep BEE 2 Star rated (service value >=4.5 to < 5 ) 64 Providing & Fixing of Heavy duty capacitor start, copper woundDouble ball bearing900/1400 RPM single phaseExhaustfan conforming to IS:2312 ISI marked in existing opening including making connections testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 65 300 mm sweep(900/1400 RPM) 66 380 mm sweep(900/1400 RPM) 67 P & F of Gravity Louver shutter of superior quality made out of frame of18 swg M.S. sheet & Louvers made from 24 swg MS Sheetwith enamel paint including cost of nuts, bolts, etc as reqd.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 68 Up to 380 mm size 69 Providing & Fixing of energy efficient direct fit (Retrofit)Polycarbonate/ GlasshousingSMD Mid Power LED tube rod(with integral driver & alumn. heat sink ), on existing fixture.system lumen efficacy ≥ 100 lm/Watt output, internal surge protection of 2.5 KV ,THD < 20% ,p.f.≥0.95,CRI >80 , life time of minimum35000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80)certificate / Report from OEM shall be submitted.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 70 1200mm , Min. Lumens output 2000 lmLED Tube rod with Polycarbonate Housing 71 Providing & Fixing of IP-20 LED Recessed / Surface Mounted, Round / SqaureSMD Mid Power LED Downlight with power coated die-cast aluminum housingwith UV Stabilized non yellowish Diffuser withBIS complience 2.5 KV surge protected Isolated driver, with Short & Open circuit protection, having efficiency > 85% . System Lumen efficacy of ≥ 110 lm / watt, THD < 10 % , Pf.≥0.95, CRI >80,life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. 72 OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 73 Surface Mounting (with extruded alumn. Housing ) 74 Minimum lumen output 2400 lm 75 Providing & Fixing of IK08, IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminummaterial with heat dissipation fins on housing with UV stabilized PC (UV stablization report submitted for UV cover ) /Toughened Glass coverand secondary lens on each LED & should be SMD type of 3 to 5 watt each . The System efficacy >=125 lm/ wt and potted driver& has a unique BIS R number withInput Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety , Power Factor >0.95 driverEfficiency >85%,THD(I) <10%Humidity 10% to 90% RH Working Temp -5C to 45C .driver current <750mA. The luminaireshall be BIS certified and Trade mark certified. Life ExpectancyEqual or more than 50000 burning hrs with Minimum 70% lumen maintened , CRI >70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external inside driver compartment. driver should be Phase to phase protection of 440 V for 4 Hrs.Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities forLED fixtures.(LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 76 LED Street Light fixture with Minimum lumen output 8700 lm 77 Providing & Fixing of Street light bracket made out from following size of B class , Medium class G.I. Pipe confirming to IS : 1239 P - 1 ( 2004 ) with heavy duty pole clamp, Saddles suitable fastners etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 78 32 mm Dia. 79 Supply, Drawing and Testing of 4 pair, 23 AWG Solid Bare Copper wire insulated with PVC, UTP (Unshielded Twisted Pair), Category 6, Class E, 100 Ohm Impedance, Indoor Cable as per latest ammendments of ANSI/TIA/EIA-568 , The copper conductors should be balanced twisted in pairs, seperated by a cross-member fluted pair divider & protected byPVC Jacket. Certified performance in a 4-connector configuration upto 100 Mtrs channel requirements & transmission frequencies up to 250 Mhz. in existing MS/PVC Conduits/casing capping including making connections to Information outlets and Patch Panels with jack &ferruling at both ends for identification with necessary tools for punching, stripping, crimping and testing etc as required complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 80 Supply and Installation of unsheilded/360 degree sheilded Information outlets made of high impact plastic body with ABS, FR Grade halogen free material with provision for protection against dust in jack, suitable for Cat 6/6A application complying to latest ammendments, According. to Cat. 6/6A channel, It should support channel as well as components requirements of Cat.6/6A standards at frequencies of up to 250 to 500 Mhz. Cat 6/6A unshielded/shielded Jack should be suitable to terminate 4 pair, 23/24 AWG solid/stranded wire diameters, using 100 Ohm unshielded/shielded balance twisted pair cable, the jack should have tooless/impact termination on reliable copper tin plated Insulation displacement contact, with easy lock mechanism, It supports IEC 60603-7-4 and complied with ANSI/TIA/EIA 568 C.2 standard. jack should be RJ11,RJ12 & RJ45 compatible. Should support Ethernet 1.2 Gb/s ATM,Digital video and broadband/baseband analog video, Voice over internet protocal (VOIP) Specifications in existing modular/MS Boxes along with necessory connections as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 81 Cat 6, Un-sheilded Information Outlet 82 Supply & fixing of square Faceplate for Flush / Surface Mount Information Outlets Single/Dual or Quad Aperture ,material should bePC+ABS body, Suitable for RJ45 unshielded/shielded connection modules. Should match with I. O. OEM. Dimensions should be 86mm X 86mm as required complete in all respect.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 83 Single Aperture 84 Supply , Installation and Testing of 4 pair, 100 Ohm impedance, Cat 6/6A /Class E/Ea patch cords should be constructed of minimum 23/24 AWG, stranded bare Copper cable with FRPVC/LSZH Jacket, with an enhanced performance by factory moulded RJ45 connectors with strain relief boots as per ANSI/TIA/EIA 568-C.2 suitable for Cat 6/6A application complying to latest ammendments Category 6/6A Standards, According. to TIA568C.2, ISO/IEC 11801, EN 50173, IEC 60603-7-51, EN 60603-7, IEEE 802.3an minimum requirement for 1G BASE-T to 10G BASE-T performance. Patch cords shall be straight thru cable compatible with both T568-A and T568-B wiring schemes, should support IEEE 802.3af / IEEE 802.3at for POE applications, Minimum 750 to 1000 mating cycles in plug contacts for long durability, Should support Ethernet 10GBASE-T, 1.2 Gb/s ATM, Token ring 4/16, Digital video and broadband/baseband analog video, Voice over internet protocal (VOIP).All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 85 Cat 6, U/UTP (Unscreened/Un-sheilded Twisted Pair) Patch Cord 86 2 Mtr 87 Supply, Installation, OTDR Testing & Fusion Splicing of Fiber Multimode Pigtail (50/125 µm) made of glass fiber optic,should be fitted at one end with any one type of single ST/E-2000/SC/LC/MT-RJ/PC type connector in acc., as per latest ammendments of TIA/EIA 569Standard Specification as per requirments complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 88 Supply, Installation, & Testing of 19 1U Rack Mounted/ surface mounted aluminum/ CRCA 1.2mm powder coated, Singlemode glass Fiber Optic Cable Patch panel/LIU loaded with flangless/screwable duplex adapters for ST/E-2000/SC/LC/MT-RJ/PC type, It should have easy removable Top plate with push buttons, there should be a splice tray installed in the Patch panel/LIU which can handle the fiber cores, splice tray should be PC+ABS material, it should include accessories like mounting hardware, gormetts, heat shrink tubes/sleevs, screws, nuts to install the panel for rack/wallmount applications as per requirment complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 89 12 Ports 90 Supply , Installation, Testing and Comissioning ofManaged Layer-2 Intelligent 10/100 Ethernet Switch providing 24 x 10/100/1000 MBPS Giga Ethernet ports / with min 2 SFP Giga Ports (provision for Fiber Giga connectivity) with related LAN Base Software including making connections etc as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 91 Supply , Installation, Testing and Comissioning ofInverter type Air Cooled Hi Wall split type Air conditioners with latest star rating system as per BEE amended upto date complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU), R-32/R-410 Green Refrigerant, wireless Remote control, suitable for working between 230V +/- 10% with low & high voltage cutoff and50 hz , single phaseACsupply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 92 1.5 TR ISEER not less then 3.8 93 Supply, Fixing and testing of following capacity ISO certified company made wall mounted stabilizer having output voltage variation from 200 V to 250 V(+/-5%) with input voltage variation from 170 V to 260 V, time delay facility from 2 to 4 minute and high cutoff at 270 V with providing of 16 Amp /20 Amp Industrialplug top making connection etc complete in all respect.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 94 4 kVA 95 Making hole in stone masonary/ RCC wall/ RCC slab with core cutter for accomodating refrigerant pipe/ drain pipe/ MS pipe/ cables etc of following dia 96 100 mm dia per running inch length 97 Providing & Fixing of IS : 4985 - 2000 Class -4 (10 Kgf / Sqcm) UPVC drain water piping withfittings (IS:7834 & 10Kgf/sqcm) like elbow, socket, Tee, solvent cement jointing,support with MS hanger on ceiling or recessed in wallwith chasing & plastering with 6 mmthickclosedcellelastomeric nitrile rubberinsulation including leakage testing etc. as required of following Nominal sizes. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 98 20 mm 99 Supply & fixing MS powder coated stand suitable for 1.0/1.5/ 2.0 Tr outdoor type of Split AC.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 100 Supply & Fixing of Dry Powder Agent (as per IS 4308:2019), ABC typeFire Extinguisher (Stored Pressure type) conforming to IS:15683:2018 , Powder coated Internal & External Surface Deep drawn cylinder body of Mild Steel CR2 grade conforming to IS: 513, Squeeze grip Forged brass release valve with Inbuilt safety release device, Diaphragm Type, 0 to 28 bar range pressure gauge, 450 mm long EPDM discharge tube, QR code for Product Traceability including Fixing on wall with suitable Anchor Fasteners as required of following capacity. Test Certificates of all the Parameters along with Hydro test & Burst test (For Cylinder Body) Certificatefrom OEM / External NABL Accrediated Lab is to be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 101 4 kg
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 6
45.
Health and Family Welfare #10187074 Price Bid
Tender For Electrification Work In Bphu And Bphl At Chc Dhawa, Block Dhawa District Jodhpur Rural - 1 (Electrical BSR 2022 Rajasthan) Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)inrecessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit & itsISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thickHot Dipped Galvanized Modular Box with earth terminal, 10A Modular switch,Modular face plate with grid plate, 3 pin ceiling rose / Holder /3 way connector, screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR. Short point (up to 3 mtr.) 2 Short point (up to 3 mtr.) 3 Medium point (up to 6 mtr.) 4 Long point(up to 10 mtr.) 5 Wiring of twin control light point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)in recessed ISI markedMMS ( IS:9537 P - III ) PVC conduit & its ISI marked (IS:3419-1988) accessories, round tiles, 2 Nos Hot Dipped Galvanized M.S Modularbox of 1.2 mm thickwith earth terminal,2 Nos10 A two way Modular switch, 3 pin ceiling rose / holder / 3 way connector ,Modular face plate with grid plate,screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR 6 Medium point (up to 6 mtr.) 7 Long point(up to 10 mtr.) 8 Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal sizeFR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) inrecessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & its ISI marked (IS:3419-1988)accessories, Hot Dipped GalvanizedModular box of 1.2 mm thick with earth terminal, 10 A modularswitch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR 9 On board 10 S&F following sizes (dia.) of ISI marked virgin material MMS ( IS:9537 P - III ) PVC conduit along withISI marked (IS:3419-1988) accessories as requiredinrecessincludingcutting the wall, covering conduit and making good the same as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 11 20 mm 12 25 mm 13 32 mm 14 Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 forlower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5,in existingsurface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure A attached with this BSR 15 2 x 2.5 sq. mm. + 1x1.5sqmm 16 1 x 4.0 sq.mm 17 2 x 4.0 sq. mm. + 1 x 2.5 sq. mm. 18 4 x 6.0 sq.mm 19 4 x 10.0 sq.mm 20 P & F 1.2 mm thickG. I. / M .S. Sheet boxes duly finished with two coats of red oxide and with earthing terminal of following sizes (nominal size) in recessed/surface as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 21 1.2 mm thickG Iboxes 22 100mm x 100mm x 60mm 23 P & F paper phenolic resin bondedlaminates confirming to IS : 2036 -1995 for boxes/ frames including making holes for switches etc, with brass screws, washers/ zinc platednut and bolts as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 24 3.0 mm thick 25 P & F phenolic laminated sheet 2.0 mm thick of following size . Including screws, cup washer as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 26 75 mm dia 27 P & F 1.2mm thickM.S. Recessed fan box, hexagonal/ round of size 130 mm dia, depth 75mm,12 mm dia rod fan hook with 100 mmlength extended on each side . All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure A attached with this BSR 28 Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load andsite requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting ofclass 3 as per IEC,minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted inexisting distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above ratingincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 29 Single pole MCB (With B/C curve tripping Characteristics) 30 6 A to 32 A rating 31 Four pole MCB (With B/C curve tripping Characteristics) 32 50/63 A rating 33 Providing & Fixing of Recessed/surface mounting heavy duty horizontal type Double Door ( Metal / Glazed )Distribution board with Metal end box made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3, powder painted complete with reversible door (for double door DB only )100 amp. insulated copper bus bar/shorting link , copper neutral link, copper earth link , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, Ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 34 Metal door (Three phase) IK-09 and IP-43with Metal end box 35 8 Way 36 Providing & Fixing of Recessed/surface mounting heavy duty Vertical TPN Distribution board with Metal end box with provision of incomer suitable for 3/4 pole MCCB and SP / TP MCB as outgoing ,made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3. powder painted with reversible door (for double door DB only ) complete with insulated 160 (upto 160 A Incomer) / 250 Amp. copper bus bar, neutral bars with shrouds, earth bar , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure A attached with this BSR 37 Double door IP-43 & IK-09 with Provision of Incomer MCCB 100/ 125 A Rating with Metal end box 38 4 Way 39 Providing & Fixing ofISI marked (IS:371) 6 amp surface type 3 pin ceiling rose with CM/L no. printed and made out from industrial grade Polycarbonate or fire resistant ABS material, brass terminal & captive screws including making connection testing etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 40 Providing & Fixing of ISI marked (IS:1258) batten/angle lampholder with CM/L no. printed and made out from industrial grade Polycarbonate or fire resistant ABS material, brass terminal & captive screwsincluding making connection testing etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 41 P & F of Industrial plug and socket conforming to IEC 60309-1/2 made out of self extinguishing engineering polymer / polyamide, nickel plated brass sleeve and pins, socket with shutter including making connection etc as reqd. For additional technical parameters of product / work refer Annexure A attached with this BSR 42 IP -67 Surface/Wall mounted socket 43 32 A 3 pin(2P+E) 44 Providing & Fixing of modular type 120 W Step Fan regulator duly ISI marked (IS 11037:1984 ) with CM/L no. printedmade out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating ,includingall as per pre approved by Engineer in charge,making connections, testing etc. as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 45 5 step fan regulator 2 Module 360 dgree rotating 46 SITC of3 /4pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant materialhaving following current rating, short circuitbreaking capacityat 440/415 V, 50 Hz; O/L & S/C settings , conforming to IS/IEC 60947 P -2 :2003 with frontface and centralised adjustable, trip free mechanisum, true contact position indicator,line load interchangeability,designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree,pollution degree 3, having positive isolation capability, push(test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% Icu. U imp =8 KV, rated insulation voltage690 V.provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connectionsetc. as required.OEM shall have submitNABL / CPRI / ERDA accrediated lab type test certificate before execution All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 47 4 pole MCCB With Thermal Magnetic release 48 125 Amp , 25 kA, adjustable O/L & adjustable S/C setting, 49 Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed ArrmouredAluminiumcable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV withH4- Grade electrolyticaluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) includingtesting etc. as required of following size. OEM must have its own in house NABL accrediated Laboratory for testing procedure as per IS:10810.For additional technical parameters of product / work refer Annexure A attached with this BSR 50 50.0 Sq. mm 51 3.5 core 52 Supplyandinstallationofhigh tensile low carbon steel rod molecularly bonded with 99.9 % Copperthickness (250 microns) andconfirming toUL 467, IS/IEC 62561-2of following size and length and as per point mentioned (a), (b), [c), (d), (e) below :- 53 (a) Bore a hole of dia. 100 mm of required length, Place the rod in the centre of Hole 54 (b)filled with anti corrosiveconductivecompounds with the permanent sealings at both the ends, CPRI/ ERDAtested with RMS capacity of minimum 30 KA for withstanding 1 second .To ensure the moisture content and electrical conductivity, 25 kg for 2000 mm & 50 Kgs for 3000mm of resistance lowering earth enhancement material shall be used as a backfill compound. The compound shall be tested form NABL acredeated labfor lowresistivity ( less than 0.12 Ohm - meter ) & high conductivity in nature with carbon as a major contentas per referance of IS 3043-1987,IEEE 80-2013 (clause 14.5d) , IEEE 837 & IER 1956 with latest amendemnts 55 © Connect the rod with copper Strip/Conductor/Wire with suitable clamp made from tinned copper and SS 304 Bolt 56 (d) Place Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height250 to 300 mm. 57 (d)Testing of earth resistance for value of 5 ohms or lessas required & must record by engineer in charge during site visit and ensure to enter in measurment book. 58 (e) Test certificatesfor confirming above standards from OEM is mandatory. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 59 17.2 mm thick and 3 Mtr. Long 60 Supply & Laying following size earth stripin horizontal or vertical run in surface by means of Earth strip DMC Insulatorincluding riveting/ soldering/ welding, Jointing shall be done by overlapping and with 2 set of Brass (for Cu strip) / GI (for GI Strip) nut bolt & spring washer spaced at 50cm making connection etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 61 25mm x 3mm Alum. Strip 62 Providing & Fixing ofBEEStar rated copper wounded double ball bearing capacitor start, aluminium body & Metallicblade ceilingfanConforming to all the performance requirements laid down in IS 374:2019 including all amendments, as applicable ; & Carry BIS licensing (i.e. ISI marking) with down rod up to 80 cm with secondary support safety cable ( steel rope) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 63 1200 mm Sweep BEE 2 Star rated (service value >=4.5 to < 5 ) 64 Providing & Fixing of Heavy duty capacitor start, copper woundDouble ball bearing900/1400 RPM single phaseExhaustfan conforming to IS:2312 ISI marked in existing opening including making connections testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 65 300 mm sweep(900/1400 RPM) 66 380 mm sweep(900/1400 RPM) 67 P & F of Gravity Louver shutter of superior quality made out of frame of18 swg M.S. sheet & Louvers made from 24 swg MS Sheetwith enamel paint including cost of nuts, bolts, etc as reqd.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 68 Up to 380 mm size 69 Providing & Fixing of energy efficient direct fit (Retrofit)Polycarbonate/ GlasshousingSMD Mid Power LED tube rod(with integral driver & alumn. heat sink ), on existing fixture.system lumen efficacy ≥ 100 lm/Watt output, internal surge protection of 2.5 KV ,THD < 20% ,p.f.≥0.95,CRI >80 , life time of minimum35000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80)certificate / Report from OEM shall be submitted.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 70 1200mm , Min. Lumens output 2000 lmLED Tube rod with Polycarbonate Housing 71 Providing & Fixing of IP-20 LED Recessed / Surface Mounted, Round / SqaureSMD Mid Power LED Downlight with power coated die-cast aluminum housingwith UV Stabilized non yellowish Diffuser withBIS complience 2.5 KV surge protected Isolated driver, with Short & Open circuit protection, having efficiency > 85% . System Lumen efficacy of ≥ 110 lm / watt, THD < 10 % , Pf.≥0.95, CRI >80,life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. 72 OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 73 Surface Mounting (with extruded alumn. Housing ) 74 Minimum lumen output 2400 lm 75 Providing & Fixing of IK08, IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminummaterial with heat dissipation fins on housing with UV stabilized PC (UV stablization report submitted for UV cover ) /Toughened Glass coverand secondary lens on each LED & should be SMD type of 3 to 5 watt each . The System efficacy >=125 lm/ wt and potted driver& has a unique BIS R number withInput Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety , Power Factor >0.95 driverEfficiency >85%,THD(I) <10%Humidity 10% to 90% RH Working Temp -5C to 45C .driver current <750mA. The luminaireshall be BIS certified and Trade mark certified. Life ExpectancyEqual or more than 50000 burning hrs with Minimum 70% lumen maintened , CRI >70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external inside driver compartment. driver should be Phase to phase protection of 440 V for 4 Hrs.Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities forLED fixtures.(LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 76 LED Street Light fixture with Minimum lumen output 8700 lm 77 Providing & Fixing of Street light bracket made out from following size of B class , Medium class G.I. Pipe confirming to IS : 1239 P - 1 ( 2004 ) with heavy duty pole clamp, Saddles suitable fastners etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 78 32 mm Dia. 79 Supply, Drawing and Testing of 4 pair, 23 AWG Solid Bare Copper wire insulated with PVC, UTP (Unshielded Twisted Pair), Category 6, Class E, 100 Ohm Impedance, Indoor Cable as per latest ammendments of ANSI/TIA/EIA-568 , The copper conductors should be balanced twisted in pairs, seperated by a cross-member fluted pair divider & protected byPVC Jacket. Certified performance in a 4-connector configuration upto 100 Mtrs channel requirements & transmission frequencies up to 250 Mhz. in existing MS/PVC Conduits/casing capping including making connections to Information outlets and Patch Panels with jack &ferruling at both ends for identification with necessary tools for punching, stripping, crimping and testing etc as required complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 80 Supply and Installation of unsheilded/360 degree sheilded Information outlets made of high impact plastic body with ABS, FR Grade halogen free material with provision for protection against dust in jack, suitable for Cat 6/6A application complying to latest ammendments, According. to Cat. 6/6A channel, It should support channel as well as components requirements of Cat.6/6A standards at frequencies of up to 250 to 500 Mhz. Cat 6/6A unshielded/shielded Jack should be suitable to terminate 4 pair, 23/24 AWG solid/stranded wire diameters, using 100 Ohm unshielded/shielded balance twisted pair cable, the jack should have tooless/impact termination on reliable copper tin plated Insulation displacement contact, with easy lock mechanism, It supports IEC 60603-7-4 and complied with ANSI/TIA/EIA 568 C.2 standard. jack should be RJ11,RJ12 & RJ45 compatible. Should support Ethernet 1.2 Gb/s ATM,Digital video and broadband/baseband analog video, Voice over internet protocal (VOIP) Specifications in existing modular/MS Boxes along with necessory connections as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 81 Cat 6, Un-sheilded Information Outlet 82 Supply & fixing of square Faceplate for Flush / Surface Mount Information Outlets Single/Dual or Quad Aperture ,material should bePC+ABS body, Suitable for RJ45 unshielded/shielded connection modules. Should match with I. O. OEM. Dimensions should be 86mm X 86mm as required complete in all respect.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 83 Single Aperture 84 Supply , Installation and Testing of 4 pair, 100 Ohm impedance, Cat 6/6A /Class E/Ea patch cords should be constructed of minimum 23/24 AWG, stranded bare Copper cable with FRPVC/LSZH Jacket, with an enhanced performance by factory moulded RJ45 connectors with strain relief boots as per ANSI/TIA/EIA 568-C.2 suitable for Cat 6/6A application complying to latest ammendments Category 6/6A Standards, According. to TIA568C.2, ISO/IEC 11801, EN 50173, IEC 60603-7-51, EN 60603-7, IEEE 802.3an minimum requirement for 1G BASE-T to 10G BASE-T performance. Patch cords shall be straight thru cable compatible with both T568-A and T568-B wiring schemes, should support IEEE 802.3af / IEEE 802.3at for POE applications, Minimum 750 to 1000 mating cycles in plug contacts for long durability, Should support Ethernet 10GBASE-T, 1.2 Gb/s ATM, Token ring 4/16, Digital video and broadband/baseband analog video, Voice over internet protocal (VOIP).All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 85 Cat 6, U/UTP (Unscreened/Un-sheilded Twisted Pair) Patch Cord 86 2 Mtr 87 Supply, Installation, OTDR Testing & Fusion Splicing of Fiber Multimode Pigtail (50/125 µm) made of glass fiber optic,should be fitted at one end with any one type of single ST/E-2000/SC/LC/MT-RJ/PC type connector in acc., as per latest ammendments of TIA/EIA 569Standard Specification as per requirments complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 88 Supply, Installation, & Testing of 19 1U Rack Mounted/ surface mounted aluminum/ CRCA 1.2mm powder coated, Singlemode glass Fiber Optic Cable Patch panel/LIU loaded with flangless/screwable duplex adapters for ST/E-2000/SC/LC/MT-RJ/PC type, It should have easy removable Top plate with push buttons, there should be a splice tray installed in the Patch panel/LIU which can handle the fiber cores, splice tray should be PC+ABS material, it should include accessories like mounting hardware, gormetts, heat shrink tubes/sleevs, screws, nuts to install the panel for rack/wallmount applications as per requirment complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 89 12 Ports 90 Supply , Installation, Testing and Comissioning ofManaged Layer-2 Intelligent 10/100 Ethernet Switch providing 24 x 10/100/1000 MBPS Giga Ethernet ports / with min 2 SFP Giga Ports (provision for Fiber Giga connectivity) with related LAN Base Software including making connections etc as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 91 Supply , Installation, Testing and Comissioning ofInverter type Air Cooled Hi Wall split type Air conditioners with latest star rating system as per BEE amended upto date complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU), R-32/R-410 Green Refrigerant, wireless Remote control, suitable for working between 230V +/- 10% with low & high voltage cutoff and50 hz , single phaseACsupply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 92 1.5 TR ISEER not less then 3.8 93 Supply, Fixing and testing of following capacity ISO certified company made wall mounted stabilizer having output voltage variation from 200 V to 250 V(+/-5%) with input voltage variation from 170 V to 260 V, time delay facility from 2 to 4 minute and high cutoff at 270 V with providing of 16 Amp /20 Amp Industrialplug top making connection etc complete in all respect.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 94 4 kVA 95 Making hole in stone masonary/ RCC wall/ RCC slab with core cutter for accomodating refrigerant pipe/ drain pipe/ MS pipe/ cables etc of following dia 96 100 mm dia per running inch length 97 Providing & Fixing of IS : 4985 - 2000 Class -4 (10 Kgf / Sqcm) UPVC drain water piping withfittings (IS:7834 & 10Kgf/sqcm) like elbow, socket, Tee, solvent cement jointing,support with MS hanger on ceiling or recessed in wallwith chasing & plastering with 6 mmthickclosedcellelastomeric nitrile rubberinsulation including leakage testing etc. as required of following Nominal sizes. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 98 20 mm 99 Supply & fixing MS powder coated stand suitable for 1.0/1.5/ 2.0 Tr outdoor type of Split AC.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 100 Supply & Fixing of Dry Powder Agent (as per IS 4308:2019), ABC typeFire Extinguisher (Stored Pressure type) conforming to IS:15683:2018 , Powder coated Internal & External Surface Deep drawn cylinder body of Mild Steel CR2 grade conforming to IS: 513, Squeeze grip Forged brass release valve with Inbuilt safety release device, Diaphragm Type, 0 to 28 bar range pressure gauge, 450 mm long EPDM discharge tube, QR code for Product Traceability including Fixing on wall with suitable Anchor Fasteners as required of following capacity. Test Certificates of all the Parameters along with Hydro test & Burst test (For Cylinder Body) Certificatefrom OEM / External NABL Accrediated Lab is to be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 101 4 kg
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 9
46.
Health and Family Welfare #10187067 Price Bid
Tender For Electrification Work In Bphu And Bphl At Chc Bhaniyana Block Bhaniyana District Jaisalmer - 1 (Electrical BSR 2022 Rajasthan) Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)inrecessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit & itsISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thickHot Dipped Galvanized Modular Box with earth terminal, 10A Modular switch,Modular face plate with grid plate, 3 pin ceiling rose / Holder /3 way connector, screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR. Short point (up to 3 mtr.) 2 Short point (up to 3 mtr.) 3 Medium point (up to 6 mtr.) 4 Long point(up to 10 mtr.) 5 Wiring of twin control light point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)in recessed ISI markedMMS ( IS:9537 P - III ) PVC conduit & its ISI marked (IS:3419-1988) accessories, round tiles, 2 Nos Hot Dipped Galvanized M.S Modularbox of 1.2 mm thickwith earth terminal,2 Nos10 A two way Modular switch, 3 pin ceiling rose / holder / 3 way connector ,Modular face plate with grid plate,screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR 6 Medium point (up to 6 mtr.) 7 Long point(up to 10 mtr.) 8 Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal sizeFR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) inrecessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & its ISI marked (IS:3419-1988)accessories, Hot Dipped GalvanizedModular box of 1.2 mm thick with earth terminal, 10 A modularswitch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR 9 On board 10 S&F following sizes (dia.) of ISI marked virgin material MMS ( IS:9537 P - III ) PVC conduit along withISI marked (IS:3419-1988) accessories as requiredinrecessincludingcutting the wall, covering conduit and making good the same as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 11 20 mm 12 25 mm 13 32 mm 14 Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 forlower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5,in existingsurface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure A attached with this BSR 15 2 x 2.5 sq. mm. + 1x1.5sqmm 16 1 x 4.0 sq.mm 17 2 x 4.0 sq. mm. + 1 x 2.5 sq. mm. 18 4 x 6.0 sq.mm 19 4 x 10.0 sq.mm 20 P & F 1.2 mm thickG. I. / M .S. Sheet boxes duly finished with two coats of red oxide and with earthing terminal of following sizes (nominal size) in recessed/surface as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 21 1.2 mm thickG Iboxes 22 100mm x 100mm x 60mm 23 P & F paper phenolic resin bondedlaminates confirming to IS : 2036 -1995 for boxes/ frames including making holes for switches etc, with brass screws, washers/ zinc platednut and bolts as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 24 3.0 mm thick 25 P & F phenolic laminated sheet 2.0 mm thick of following size . Including screws, cup washer as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 26 75 mm dia 27 P & F 1.2mm thickM.S. Recessed fan box, hexagonal/ round of size 130 mm dia, depth 75mm,12 mm dia rod fan hook with 100 mmlength extended on each side . All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure A attached with this BSR 28 Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load andsite requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting ofclass 3 as per IEC,minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted inexisting distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above ratingincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 29 Single pole MCB (With B/C curve tripping Characteristics) 30 6 A to 32 A rating 31 Four pole MCB (With B/C curve tripping Characteristics) 32 50/63 A rating 33 Providing & Fixing of Recessed/surface mounting heavy duty horizontal type Double Door ( Metal / Glazed )Distribution board with Metal end box made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3, powder painted complete with reversible door (for double door DB only )100 amp. insulated copper bus bar/shorting link , copper neutral link, copper earth link , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, Ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 34 Metal door (Three phase) IK-09 and IP-43with Metal end box 35 8 Way 36 Providing & Fixing of Recessed/surface mounting heavy duty Vertical TPN Distribution board with Metal end box with provision of incomer suitable for 3/4 pole MCCB and SP / TP MCB as outgoing ,made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3. powder painted with reversible door (for double door DB only ) complete with insulated 160 (upto 160 A Incomer) / 250 Amp. copper bus bar, neutral bars with shrouds, earth bar , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure A attached with this BSR 37 Double door IP-43 & IK-09 with Provision of Incomer MCCB 100/ 125 A Rating with Metal end box 38 4 Way 39 Providing & Fixing ofISI marked (IS:371) 6 amp surface type 3 pin ceiling rose with CM/L no. printed and made out from industrial grade Polycarbonate or fire resistant ABS material, brass terminal & captive screws including making connection testing etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 40 Providing & Fixing of ISI marked (IS:1258) batten/angle lampholder with CM/L no. printed and made out from industrial grade Polycarbonate or fire resistant ABS material, brass terminal & captive screwsincluding making connection testing etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 41 P & F of Industrial plug and socket conforming to IEC 60309-1/2 made out of self extinguishing engineering polymer / polyamide, nickel plated brass sleeve and pins, socket with shutter including making connection etc as reqd. For additional technical parameters of product / work refer Annexure A attached with this BSR 42 IP -67 Surface/Wall mounted socket 43 32 A 3 pin(2P+E) 44 Providing & Fixing of modular type 120 W Step Fan regulator duly ISI marked (IS 11037:1984 ) with CM/L no. printedmade out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating ,includingall as per pre approved by Engineer in charge,making connections, testing etc. as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 45 5 step fan regulator 2 Module 360 dgree rotating 46 SITC of3 /4pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant materialhaving following current rating, short circuitbreaking capacityat 440/415 V, 50 Hz; O/L & S/C settings , conforming to IS/IEC 60947 P -2 :2003 with frontface and centralised adjustable, trip free mechanisum, true contact position indicator,line load interchangeability,designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree,pollution degree 3, having positive isolation capability, push(test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% Icu. U imp =8 KV, rated insulation voltage690 V.provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connectionsetc. as required.OEM shall have submitNABL / CPRI / ERDA accrediated lab type test certificate before execution All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 47 4 pole MCCB With Thermal Magnetic release 48 125 Amp , 25 kA, adjustable O/L & adjustable S/C setting, 49 Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed ArrmouredAluminiumcable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV withH4- Grade electrolyticaluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) includingtesting etc. as required of following size. OEM must have its own in house NABL accrediated Laboratory for testing procedure as per IS:10810.For additional technical parameters of product / work refer Annexure A attached with this BSR 50 50.0 Sq. mm 51 3.5 core 52 Supplyandinstallationofhigh tensile low carbon steel rod molecularly bonded with 99.9 % Copperthickness (250 microns) andconfirming toUL 467, IS/IEC 62561-2of following size and length and as per point mentioned (a), (b), [c), (d), (e) below :- 53 (a) Bore a hole of dia. 100 mm of required length, Place the rod in the centre of Hole 54 (b)filled with anti corrosiveconductivecompounds with the permanent sealings at both the ends, CPRI/ ERDAtested with RMS capacity of minimum 30 KA for withstanding 1 second .To ensure the moisture content and electrical conductivity, 25 kg for 2000 mm & 50 Kgs for 3000mm of resistance lowering earth enhancement material shall be used as a backfill compound. The compound shall be tested form NABL acredeated labfor lowresistivity ( less than 0.12 Ohm - meter ) & high conductivity in nature with carbon as a major contentas per referance of IS 3043-1987,IEEE 80-2013 (clause 14.5d) , IEEE 837 & IER 1956 with latest amendemnts 55 © Connect the rod with copper Strip/Conductor/Wire with suitable clamp made from tinned copper and SS 304 Bolt 56 (d) Place Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height250 to 300 mm. 57 (d)Testing of earth resistance for value of 5 ohms or lessas required & must record by engineer in charge during site visit and ensure to enter in measurment book. 58 (e) Test certificatesfor confirming above standards from OEM is mandatory. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 59 17.2 mm thick and 3 Mtr. Long 60 Supply & Laying following size earth stripin horizontal or vertical run in surface by means of Earth strip DMC Insulatorincluding riveting/ soldering/ welding, Jointing shall be done by overlapping and with 2 set of Brass (for Cu strip) / GI (for GI Strip) nut bolt & spring washer spaced at 50cm making connection etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 61 25mm x 3mm Alum. Strip 62 Providing & Fixing ofBEEStar rated copper wounded double ball bearing capacitor start, aluminium body & Metallicblade ceilingfanConforming to all the performance requirements laid down in IS 374:2019 including all amendments, as applicable ; & Carry BIS licensing (i.e. ISI marking) with down rod up to 80 cm with secondary support safety cable ( steel rope) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 63 1200 mm Sweep BEE 2 Star rated (service value >=4.5 to < 5 ) 64 Providing & Fixing of Heavy duty capacitor start, copper woundDouble ball bearing900/1400 RPM single phaseExhaustfan conforming to IS:2312 ISI marked in existing opening including making connections testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 65 300 mm sweep(900/1400 RPM) 66 380 mm sweep(900/1400 RPM) 67 P & F of Gravity Louver shutter of superior quality made out of frame of18 swg M.S. sheet & Louvers made from 24 swg MS Sheetwith enamel paint including cost of nuts, bolts, etc as reqd.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 68 Up to 380 mm size 69 Providing & Fixing of energy efficient direct fit (Retrofit)Polycarbonate/ GlasshousingSMD Mid Power LED tube rod(with integral driver & alumn. heat sink ), on existing fixture.system lumen efficacy ≥ 100 lm/Watt output, internal surge protection of 2.5 KV ,THD < 20% ,p.f.≥0.95,CRI >80 , life time of minimum35000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80)certificate / Report from OEM shall be submitted.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 70 1200mm , Min. Lumens output 2000 lmLED Tube rod with Polycarbonate Housing 71 Providing & Fixing of IP-20 LED Recessed / Surface Mounted, Round / SqaureSMD Mid Power LED Downlight with power coated die-cast aluminum housingwith UV Stabilized non yellowish Diffuser withBIS complience 2.5 KV surge protected Isolated driver, with Short & Open circuit protection, having efficiency > 85% . System Lumen efficacy of ≥ 110 lm / watt, THD < 10 % , Pf.≥0.95, CRI >80,life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. 72 OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 73 Surface Mounting (with extruded alumn. Housing ) 74 Minimum lumen output 2400 lm 75 Providing & Fixing of IK08, IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminummaterial with heat dissipation fins on housing with UV stabilized PC (UV stablization report submitted for UV cover ) /Toughened Glass coverand secondary lens on each LED & should be SMD type of 3 to 5 watt each . The System efficacy >=125 lm/ wt and potted driver& has a unique BIS R number withInput Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety , Power Factor >0.95 driverEfficiency >85%,THD(I) <10%Humidity 10% to 90% RH Working Temp -5C to 45C .driver current <750mA. The luminaireshall be BIS certified and Trade mark certified. Life ExpectancyEqual or more than 50000 burning hrs with Minimum 70% lumen maintened , CRI >70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external inside driver compartment. driver should be Phase to phase protection of 440 V for 4 Hrs.Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities forLED fixtures.(LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 76 LED Street Light fixture with Minimum lumen output 8700 lm 77 Providing & Fixing of Street light bracket made out from following size of B class , Medium class G.I. Pipe confirming to IS : 1239 P - 1 ( 2004 ) with heavy duty pole clamp, Saddles suitable fastners etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 78 32 mm Dia. 79 Supply, Drawing and Testing of 4 pair, 23 AWG Solid Bare Copper wire insulated with PVC, UTP (Unshielded Twisted Pair), Category 6, Class E, 100 Ohm Impedance, Indoor Cable as per latest ammendments of ANSI/TIA/EIA-568 , The copper conductors should be balanced twisted in pairs, seperated by a cross-member fluted pair divider & protected byPVC Jacket. Certified performance in a 4-connector configuration upto 100 Mtrs channel requirements & transmission frequencies up to 250 Mhz. in existing MS/PVC Conduits/casing capping including making connections to Information outlets and Patch Panels with jack &ferruling at both ends for identification with necessary tools for punching, stripping, crimping and testing etc as required complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 80 Supply and Installation of unsheilded/360 degree sheilded Information outlets made of high impact plastic body with ABS, FR Grade halogen free material with provision for protection against dust in jack, suitable for Cat 6/6A application complying to latest ammendments, According. to Cat. 6/6A channel, It should support channel as well as components requirements of Cat.6/6A standards at frequencies of up to 250 to 500 Mhz. Cat 6/6A unshielded/shielded Jack should be suitable to terminate 4 pair, 23/24 AWG solid/stranded wire diameters, using 100 Ohm unshielded/shielded balance twisted pair cable, the jack should have tooless/impact termination on reliable copper tin plated Insulation displacement contact, with easy lock mechanism, It supports IEC 60603-7-4 and complied with ANSI/TIA/EIA 568 C.2 standard. jack should be RJ11,RJ12 & RJ45 compatible. Should support Ethernet 1.2 Gb/s ATM,Digital video and broadband/baseband analog video, Voice over internet protocal (VOIP) Specifications in existing modular/MS Boxes along with necessory connections as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 81 Cat 6, Un-sheilded Information Outlet 82 Supply & fixing of square Faceplate for Flush / Surface Mount Information Outlets Single/Dual or Quad Aperture ,material should bePC+ABS body, Suitable for RJ45 unshielded/shielded connection modules. Should match with I. O. OEM. Dimensions should be 86mm X 86mm as required complete in all respect.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 83 Single Aperture 84 Supply , Installation and Testing of 4 pair, 100 Ohm impedance, Cat 6/6A /Class E/Ea patch cords should be constructed of minimum 23/24 AWG, stranded bare Copper cable with FRPVC/LSZH Jacket, with an enhanced performance by factory moulded RJ45 connectors with strain relief boots as per ANSI/TIA/EIA 568-C.2 suitable for Cat 6/6A application complying to latest ammendments Category 6/6A Standards, According. to TIA568C.2, ISO/IEC 11801, EN 50173, IEC 60603-7-51, EN 60603-7, IEEE 802.3an minimum requirement for 1G BASE-T to 10G BASE-T performance. Patch cords shall be straight thru cable compatible with both T568-A and T568-B wiring schemes, should support IEEE 802.3af / IEEE 802.3at for POE applications, Minimum 750 to 1000 mating cycles in plug contacts for long durability, Should support Ethernet 10GBASE-T, 1.2 Gb/s ATM, Token ring 4/16, Digital video and broadband/baseband analog video, Voice over internet protocal (VOIP).All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 85 Cat 6, U/UTP (Unscreened/Un-sheilded Twisted Pair) Patch Cord 86 2 Mtr 87 Supply, Installation, OTDR Testing & Fusion Splicing of Fiber Multimode Pigtail (50/125 µm) made of glass fiber optic,should be fitted at one end with any one type of single ST/E-2000/SC/LC/MT-RJ/PC type connector in acc., as per latest ammendments of TIA/EIA 569Standard Specification as per requirments complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 88 Supply, Installation, & Testing of 19 1U Rack Mounted/ surface mounted aluminum/ CRCA 1.2mm powder coated, Singlemode glass Fiber Optic Cable Patch panel/LIU loaded with flangless/screwable duplex adapters for ST/E-2000/SC/LC/MT-RJ/PC type, It should have easy removable Top plate with push buttons, there should be a splice tray installed in the Patch panel/LIU which can handle the fiber cores, splice tray should be PC+ABS material, it should include accessories like mounting hardware, gormetts, heat shrink tubes/sleevs, screws, nuts to install the panel for rack/wallmount applications as per requirment complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 89 12 Ports 90 Supply , Installation, Testing and Comissioning ofManaged Layer-2 Intelligent 10/100 Ethernet Switch providing 24 x 10/100/1000 MBPS Giga Ethernet ports / with min 2 SFP Giga Ports (provision for Fiber Giga connectivity) with related LAN Base Software including making connections etc as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 91 Supply , Installation, Testing and Comissioning ofInverter type Air Cooled Hi Wall split type Air conditioners with latest star rating system as per BEE amended upto date complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU), R-32/R-410 Green Refrigerant, wireless Remote control, suitable for working between 230V +/- 10% with low & high voltage cutoff and50 hz , single phaseACsupply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 92 1.5 TR ISEER not less then 3.8 93 Supply, Fixing and testing of following capacity ISO certified company made wall mounted stabilizer having output voltage variation from 200 V to 250 V(+/-5%) with input voltage variation from 170 V to 260 V, time delay facility from 2 to 4 minute and high cutoff at 270 V with providing of 16 Amp /20 Amp Industrialplug top making connection etc complete in all respect.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 94 4 kVA 95 Making hole in stone masonary/ RCC wall/ RCC slab with core cutter for accomodating refrigerant pipe/ drain pipe/ MS pipe/ cables etc of following dia 96 100 mm dia per running inch length 97 Providing & Fixing of IS : 4985 - 2000 Class -4 (10 Kgf / Sqcm) UPVC drain water piping withfittings (IS:7834 & 10Kgf/sqcm) like elbow, socket, Tee, solvent cement jointing,support with MS hanger on ceiling or recessed in wallwith chasing & plastering with 6 mmthickclosedcellelastomeric nitrile rubberinsulation including leakage testing etc. as required of following Nominal sizes. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 98 20 mm 99 Supply & fixing MS powder coated stand suitable for 1.0/1.5/ 2.0 Tr outdoor type of Split AC.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 100 Supply & Fixing of Dry Powder Agent (as per IS 4308:2019), ABC typeFire Extinguisher (Stored Pressure type) conforming to IS:15683:2018 , Powder coated Internal & External Surface Deep drawn cylinder body of Mild Steel CR2 grade conforming to IS: 513, Squeeze grip Forged brass release valve with Inbuilt safety release device, Diaphragm Type, 0 to 28 bar range pressure gauge, 450 mm long EPDM discharge tube, QR code for Product Traceability including Fixing on wall with suitable Anchor Fasteners as required of following capacity. Test Certificates of all the Parameters along with Hydro test & Burst test (For Cylinder Body) Certificatefrom OEM / External NABL Accrediated Lab is to be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 101 4 kg
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
47.
Power #10172978 AOC
Tender For Annual Maintenance Repair Of Md Dvvnl Office Vidyut Adhikari Colony At 220 Kv Sub Station, Sikandra, Agra - Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by Engineer-in- Charge: (DSR 2.1) All kinds of soil (DSR 2.1.1) 2 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and for all lift, as directed by Engineer-in-charge. (DSR 2.6) All kinds of soil (DSR 2.6.1) 3 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.(DSR 2.8) All kinds of soil. (DSR 2.8.1) 4 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 and for all lift. (DSR )(DSR 2.25) 5 Excavating, supplying, stacking and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in foundation trenches, plinth, sides of foundation etc. complete for all lift. (DSR )(DSR 2.25(a)) 6 Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials. (DSR 2.26) All kinds of soil (DSR 2.26.1) 7 Supplying and filling in plinth withsand under floors, including watering, ramming, consolidating and dressing complete. (DSR )(DSR 2.27) 8 Surface dressing of the ground including removing vegetation and in-equalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m. (DSR 2.28) All kinds of soil (DSR 2.28.1) 9 Ploughing the existing ground to a depth of 15 cm to 25 cm and watering the same. (DSR 2.29) All kinds of soil (DSR 2.29.1) 10 Excavating holes more than 0.10 cum & upto 0.5 cum including getting out the excavated soil, then returning the soil as required in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering etc, disposing of surplus excavated soil, as directed within a lead of 50 m and lift upto 1.5 m. (DSR 2.3) All kinds of soil (DSR 2.30.1) 11 Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared. (DSR )(DSR 2.31) 12 Clearing grass and removal of the rubbish up to a distance of 50 m outside the periphery of the area cleared. (DSR )(DSR 2.32) 13 Supplying chemical emulsion in sealed containers including delivery as specified. (DSR 2.34) Chlorpyriphos/ Lindane emulsifiable concentrate of 20% (DSR 2.34.1) 14 Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : (DSR 2.35) Along external wall where the apron is not provided using chemical emulsion @ 7.5 litres / sqm of the vertical surface of the substructure to a depth of 300mm including excavation channel along the wall & rodding etc. complete: 2.35.1 With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration (DSR 2.35.1.1) 15 Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : (DSR 2.35) Along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc.: 2.35.2 With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration (DSR 2.35.2.1) 16 Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : (DSR 2.35) Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: 2.35.3 With Chlorpyriphos/Lindane E.C. 20% with 1% concentration (DSR 2.35.3.1) 17 Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : (DSR 2.35) Treatment of existing masonry using chemical emulsion @ one litre per hole at 300 mm interval including drilling holes at 45 degree and plugging them with cement mortar 1:2 (1 cement : 2 coarse sand) to the full depth of the hole : 2.35.4 With Chlorpyriphos/Lindane E.C. 20% with 1% concentration (DSR 2.35.4.1) 18 Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : (DSR 2.35) Treatment at points of contact of wood work by chemical emulsion Chlorpyriphos/ Lindane (in oil or kerosene based solution) @ 0.5 litres per hole by drilling 6 mm dia holes at downward angle of 45 degree at 150 mm centre to centre and sealing the same. (DSR 2.35.5) 19 Extra for levelling & neatly dressing of disposed soil completely as directed by Engineer-in-charge. (DSR )(DSR 2.36) 20 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : (DSR 4.1) 1:1½:3 (1 Cement: 1½ coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) (DSR 4.1.2) 21 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : (DSR 4.1) 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) (DSR 4.1.3) 22 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : (DSR 4.1) 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) (DSR 4.1.8) 23 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : (DSR 4.1) 1:5:10 (1 cement : 5 fine sand derived from natural sources : 10 graded stone aggregate 40 mm nominal size derived from natural sources) (DSR 4.1.11) 24 Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing: (DSR 4.2) 1:1½:3 (1 cement : 1½ coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). (DSR 4.2.2) 25 Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing: (DSR 4.2) 1:2:4 (1 Cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) (DSR 4.2.3) 26 Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing: (DSR 4.2) 1:2:4 (1 Cement : 2 coarse sand (zone-III)including manufactured sand derived from Recycled Concrete Aggregate (RCA) upto 25% : 4 graded stone aggregate 20 mm nominal size including Recycled Concrete Aggregate (RCA) upto 25%)). (DSR 4.2.3A) 27 Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing: (DSR 4.2) 1:5:10 (1 cement : 5 coarse sand (zone-III) derived from natural sources : 10 graded stone aggregate 40 mm nominal size derived from natural sources). (DSR 4.2.8) 28 Centering and shuttering including strutting, propping etc. and removal of form work for : (DSR 4.3) Foundations, footings, bases for columns (DSR 4.3.1) 29 Centering and shuttering including strutting, propping etc. and removal of form work for : (DSR 4.3) Retaining walls, return walls, walls (any thickness) including attached pilasters, buttresses, plinth and string courses fillets, kerbs and steps etc. (DSR 4.3.2) 30 Centering and shuttering including strutting, propping etc. and removal of form work for : (DSR 4.3) Columns, piers, abutments, pillars, posts and struts (DSR 4.3.3) 31 Providing and laying cement concrete in kerbs, steps and the like at or near ground level excluding the cost of centering, shuttering and finishing. (DSR 4.4) 1:1½:3 (1 Cement: 1½ coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) (DSR 4.4.1) 32 Providing and fixing up to floor five level precast cement concrete string or lacing courses, copings, bed plates, anchor blocks, plain window sills, shelves, louvers, steps, stair cases, etc., including hoisting and setting in position with cement mortar 1:3 (1 Cement : 3 coarse sand), cost of required Centering complete. (DSR 4.5) 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20mm nominal size derived from natural sources) (DSR 4.5.1) 33 Providing and fixing at or near ground level precast cement concrete in kerbs, edgings etc. as per approved pattern and setting in position with cement mortar 1:3 (1 Cement : 3 coarse sand), including the cost of required centering, shuttering complete. (DSR 4.6) 1:1½:3 (1 Cement: 1½ coarse sand(zone-III) derived from natural sources: 3 graded stone aggregate 20 mm nominal size derived from natural sources). (DSR 4.6.1) 34 Providing and fixing up to floor five level precast cement concrete solid block, including hoisting and setting in position with cement mortar 1:3 (1 cement : 3 coarse sand), cost of required centering, shuttering complete : (DSR 4.7) 1:1½:3 (1 Cement: 1½ coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). (DSR 4.7.1) 35 Precasting and placing in position 125 mm dia Bollards 600 mm high of required shape including providing M.S. Pipe Sleeve 50 mm dia 300 mm long in the Bollard and M.S. Pipes 40 mm dia and 450mm long with 150x150x6mm M.S. plate welded at bottom and embedded 150mm in cement concrete 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources), including necessary excavation of size 250x250x450mm deep for the same in bitumen/concrete pavement at specified spacing. (DSR )(DSR 4.9) 36 Providing and laying damp-proof course 50mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20mm nominal size derived from natural sources).(DSR )(DSR 4.11) 37 Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturers specification. (DSR )(DSR 4.12) 38 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : (DSR 5.1) C (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) (DSR 5.1.2) 39 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : (DSR 5.2) 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) (DSR 5.2.2) 40 Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). (DSR )(DSR 5.3) 41 Providing and laying reinforced cement concrete in kerbs, steps and the like at or near ground level excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). (DSR )(DSR 5.4) 42 Reinforced cement concrete work in arches, archribs, domes, vaults, shells, folded plate and roofs having slope more than 15° up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). (DSR )(DSR 5.5) 43 Reinforced cement concrete work in chimneys, shafts, up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). (DSR )(DSR 5.6) 44 Reinforced cement concrete work in vertical and horizontal fins individually or forming box louvers, facias and eaves boards above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20mm nominal size derived from natural sources). (DSR )(DSR 5.8) 45 Centering and shuttering including strutting, propping etc. and removal of form for (DSR 5.9) Foundations, footings, bases of columns, etc. for mass concrete (DSR 5.9.1) 46 Centering and shuttering including strutting, propping etc. and removal of form for (DSR 5.9) Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. (DSR 5.9.2) 47 Centering and shuttering including strutting, propping etc. and removal of form for (DSR 5.9) Suspended floors, roofs, landings, balconies and access platform (DSR 5.9.3) 48 Centering and shuttering including strutting, propping etc. and removal of form for (DSR 5.9) Shelves (Cast in situ) (DSR 5.9.4) 49 Centering and shuttering including strutting, propping etc. and removal of form for (DSR 5.9) Lintels, beams, plinth beams, girders, bressumers and cantilevers (DSR 5.9.5) 50 Centering and shuttering including strutting, propping etc. and removal of form for (DSR 5.9) Columns, Pillars, Piers, Abutments, Posts and Struts (DSR 5.9.6) 51 Centering and shuttering including strutting, propping etc. and removal of form for (DSR 5.9) Stairs, (excluding landings) except spiral-staircases (DSR 5.9.7) 52 Centering and shuttering including strutting, propping etc. and removal of form for (DSR 5.9) Chimneys and shafts (DSR 5.9.11) 53 Centering and shuttering including strutting, propping etc. and removal of form for (DSR 5.9) Vertical and horizontal fins individually or forming box louvers band, facias and eaves boards(DSR 5.9.13) 54 Centering and shuttering including strutting, propping etc. and removal of form for (DSR 5.9) Small lintels not exceeding 1.5 m clear span, moulding as in cornices, window sills, string courses, bands, copings, bed plates, anchor blocks and the like (DSR 5.9.15) 55 Centering and shuttering including strutting, propping etc. and removal of form for (DSR 5.9) Edges of slabs and breaks in floors and walls 5.9.16 Under 20 cm wide (DSR 5.9.16.1) 56 Centering and shuttering including strutting, propping etc. and removal of form for (DSR 5.9) Weather shade, Chajjas, corbels etc., including edges (DSR 5.9.19) 57 Providing, hoisting and fixing above plinth level up to floor five level precast reinforced cement concrete work in string courses, bands, copings, bed plates, anchor blocks, plain window sills and the like, including the cost of required centering, shuttering but , excluding cost of reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). (DSR )(DSR 5.12) 58 Providing, hoisting and fixing up to floor five level precast reinforced cement concrete in small lintels not exceeding 1.5m clear span up to floor five level, including the cost of required centering, shuttering but , excluding the cost of reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). (DSR )(DSR 5.13) 59 Providing, transporting, hoisting and fixing above plinth level up to floor five level precast reinforced cement concrete in lintels, beams and bressumers, including setting in cement mortar 1:3 (1 cement : 3 coarse sand), cost of required centering and shuttering but , excluding the cost of reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) (DSR )(DSR 5.15) 60 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. (DSR 5.22) Thermo-Mechanically Treated bars of grade Fe-500D or more. (DSR 5.22.6) 61 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. (DSR 5.22A) Thermo-Mechanically Treated bars of grade Fe-500D or more. (DSR 5.22A.6) 62 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: (DSR 6.1) Cement mortar 1:4 (1 cement : 4 coarse sand) (DSR 6.1.1) 63 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: (DSR 6.1) Cement mortar 1:6 (1 cement : 6 coarse sand) (DSR 6.1.2) 64 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : (DSR 6.4) Cement mortar 1:4 (1 cement : 4 coarse sand) (DSR 6.4.1) 65 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : (DSR 6.4) Cement mortar 1:6 (1 cement : 6 coarse sand) (DSR 6.4.2) 66 Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. (DSR 6.13) Cement mortar 1:4 (1 cement :4 coarse sand) (DSR 6.13.2) 67 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels. (DSR 8.2) Raj Nagar Plain white marble/ Udaipur green marble/ Zebra black marble 8.2.1 Area of slab upto 0.50 sqm (DSR 8.2.1.1) 68 (DSR 8.2) Raj Nagar Plain white marble/ Udaipur green marble/ Zebra black marble 8.2.1 Area of slab over 0.50 sqm (DSR 8.2.1.2) 69 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels. (DSR 8.2) Granite stone slab of colour black, Cherry/Ruby red 8.2.2 Area of slab upto 0.50 sqm (DSR 8.2.2.1) 70 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels. (DSR 8.2) Granite stone slab of colour black, Cherry/Ruby red 8.2.2 Area of slab over 0.50 sqm (DSR 8.2.2.2) 71 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels. (DSR 8.2) Granite stone slab of all colour and texture except black, Cherry/Ruby red 8.2.3 Area of slab over 0.50 sqm (DSR 8.2.3.2) 72 Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. (DSR 8.3) Granite work (DSR 8.3.2) 73 Extra for fixing marble /granite stone, over and above corresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive, including cleaning etc. complete. (DSR )(DSR 8.4) 74 Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. (DSR )(DSR 8.5) 75 Mirror polishing on marble work/Granite work/stone work where ever required to give high gloss finish complete. (DSR )(DSR 8.6) 76 Stone work (machine cut edges) for wall lining etc. (veneer work) upto 10 metre height, backing filled with a grout of average 12 mm thick cement mortar 1:3 (1 cement : 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade : (To be secured to the backing and the sides by means of cramps and pins which shall be paid for separately) : (DSR 8.14) Red sand stone - exposed face fine dressed with rough backing. 8.14.1 30 mm thick (DSR 8.14.1.5) 77 Providing and fixing plywood 4 mm thick, one side decorative veneer conforming to IS: 1328 (type-1), for plain lining / cladding with necessary screws, including priming coat on unexposed surface with : (DSR 8.28) Decorative veneer facings of approved manufacture (DSR 8.28.1) 78 Providing and fixing skirting with Pre-laminated (one side decorative and other side balancing lamination) flat pressed 3 layer or graded particle board (medium density) Grade I, Type II, IS :12823 marked, with necessary fixing arrangements and screws, including drilling necessary holes for rawl plugs etc. and priming coat on unexposed surface complete : (DSR 8.3) 18 mm thick (DSR 8.30.1) 79 Providing and fixing skirting with Pre-laminated (one side decorative and other side balancing lamination) flat pressed 3 layer or graded particle board (medium density) Grade I, Type II, IS :12823 marked, with necessary fixing arrangements and screws, including drilling necessary holes for rawl plugs etc. and priming coat on unexposed surface complete : (DSR 8.3) 25 mm thick (DSR 8.30.2) 80 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. (DSR )(DSR 8.31) 81 Designing, fabricating, testing, installing and fixing in position Curtain Wall with Aluminium Composite Panel Cladding, with open grooves for linear as well as curvilinear portions of the building , for all heights and all levels etc. including:(a) Structural analysis & design and preparation of shop drawings for pressure equalisation or rain screen principle as required, proper drainage of water to make it watertight including checking of all the structural and functional design.(b) Providing, fabricating and supplying and fixing panels of aluminium composite panel cladding in pan shape in metalic colour of approved shades made out of 4mm thick aluminium composite panel material consisting of 3mm thick FR grade mineral core sandwiched between two Aluminium sheets (each 0.5mm thick). The aluminium composite panel cladding sheet shall be coil coated, with Kynar 500 based PVDF / Lumiflon based fluoropolymer resin coating of approved colour and shade on face # 1 and polymer (Service) coating on face # 2 as specified using stainless steel screws, nuts, bolts, washers, cleats, weather silicone sealant, backer rods etc. (c) The fastening brackets of Aluminium alloy 6005 T5 / MS with Hot Dip Galvanised with serrations and serrated washers to arrest the wind load movement, fasteners, SS 316 Pins and anchor bolts of approved make in SS 316, Nylon separators to prevent bi-metallic contacts all complete required to perform as per specification and drawing The item includes cost of all material & labour component, the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working curtain wall with aluminium composite panel cladding, cleaning and protection of the curtain wall with aluminium composite panel cladding till the handing over of the building for occupation. Base frame work for ACP cladding is payable under the relevant aluminium item.s The Contractor shall provide curtain wall with aluminium composite panel cladding, having all the performance characteristics all complete , as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer-in-Charge. However, for the purpose of payment, only the actual area on the external face of the curtain wall with Aluminum Composite Panel Cladding (including width of groove) shall be measured in sqm. up to two decimal places. (DSR )(DSR 8.32) 82 Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately). (DSR 9.1) Sal wood (DSR 9.1.2) 83 Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows, fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note:- Butt hingesand necessary screwsshall be paid separately) (DSR 9.5) Second class teak wood 9.5.1 35 mm thick shutters (DSR 9.5.1.1) 84 Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows, fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note:- Butt hingesand necessary screwsshall be paid separately) (DSR 9.5) Second class teak wood 9.5.1 30 mm thick shutters (DSR 9.5.1.2) 85 Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick : (DSR 9.7) Second class teak wood (DSR 9.7.1) 86 Providing and fixing glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes (weight not less than 10 kg per sqm) fixing with ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws. (DSR 9.9) Second class teak wood 9.9.1 35 mm thick (DSR 9.9.1.1) 87 Providing and fixing glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes (weight not less than 10 kg per sqm) fixing with ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws. (DSR 9.9) Second class teak wood 9.9.1 30 mm thick (DSR 9.9.1.2) 88 Extra for providing heavy sheet float glass panes instead of ordinary float glass in glazed doors, windows and clerestory window shutters. (Area of opening for glass panes excluding portion inside rebate shall be measured) (DSR 9.11) 5.0 mm thick(weight not less than 12.50 kg per sqm) instead of 4 mm thick(weight not less than 10 kg per sqm). (DSR 9.11.1) 89 Extra for providing frosted glass panes 4 mm thick (weight not less than 10 kg per sqm) instead of ordinary float glass panes 4 mm thick(weight not less than 10 kg per sqm) in doors, windows and clerestory window shutters. (Area of opening for glass panes excluding portion inside rebate shall be measured). (DSR )(DSR 9.12) 90 Extra for providing ISI marked Stainless Steel butt hinges instead of M.S. pressed butt hinges bright finished of required size with necessary screws. (Shutter area to be measured). (DSR )(DSR 9.14) 91 Providing and fixing 25 mm thick shutters for cup board etc. : (DSR 9.16) Panelled or panelled & glazed shutters : 9.16.1 Second class teak wood including ISI marked nickel plated bright finished M.S. piano hinges with necessary screws (DSR 9.16.1.2) 92 Providing and fixing 25 mm thick shutters for cup board etc. : (DSR 9.16) Glazed shutters : 9.16.2 Second class teak wood including ISI marked nickel plated bright finished M.S. piano hinges with necessary screws (DSR 9.16.2.2) 93 Providing and fixing flat pressed three layer particle or gradedplain wood board medium density exterior grade (Grade I) FPT-I, conforming and markedto frame, backing or studding with screws etc. complete (Frames, backing or studding to be paid separately): (DSR 9.17) 12 mm thick (DSR 9.17.1) 94 Providing and fixing flat pressed three layer particle or gradedplain wood board medium density exterior grade (Grade I) FPT-I, conforming and markedto frame, backing or studding with screws etc. complete (Frames, backing or studding to be paid separately): (DSR 9.17) 18 mm thick (DSR 9.17.2) 95 Providing and fixing Pre-laminated flat pressed 3 layer (medium density) particle board or graded wood particle board IS : 3087 marked, with one side decorative and other side balancing lamination Grade I, Type II exterior grade IS : 12823 marked, in shelves with screws and fittings wherever required, edges to be painted with polyurethane primer (fittings to be paid separately). (DSR 9.18) 18 mm thick (DSR 9.18.1) 96 Providing and fixing Pre-laminated flat pressed 3 layer (medium density) particle board or graded wood particle board IS : 3087 marked, with one side decorative and other side balancing lamination Grade I, Type II exterior grade IS : 12823 marked, in shelves with screws and fittings wherever required, edges to be painted with polyurethane primer (fittings to be paid separately). (DSR 9.18) 25 mm thick (DSR 9.18.2) 97 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. (DSR 9.2) 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws (DSR 9.20.1) 98 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. (DSR 9.2) 30 mm thick including ISI marked Stainless Steel butt hinges with necessary screws (DSR 9.20.2) 99 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. (DSR 9.2) 25 mm thick (for cupboard) including ISI marked nickel plated bright finished M.S. Piano hinges IS : 3818 marked with necessary screws (DSR 9.20.3) 100 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: (DSR 9.21) 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws (DSR 9.21.1) 101 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: (DSR 9.21) 30 mm thick including ISI marked Stainless Steel butt hinges with necessary screws (DSR 9.21.2) 102 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: (DSR 9.21) 25 mm thick (for cupboard) including ISI marked nickel plated bright finished M.S. piano hinges with necessary screws (DSR 9.21.3) 103 Extra if louvers (not exceeding 0.2 sqm) are provided in flush door shutters (overall area of door shutters to be measured). (DSR 9.25) Decorative type door (DSR 9.25.1) 104 Extra for cutting rebate in flush door shutters (Total area of the shutter to be measured). (DSR )(DSR 9.26) 105 Providing and fixing wire gauge shutters using galvanized M.S. wire gauge of average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm, for doors, windows and clerestory windows with hinges and necessary screws :35 mm thick shutters (DSR 9.27.1) with ISI marked M.S. pressed butt hinges bright finished of required size 9.27.1.1 Second class teak wood (DSR 9.27.1.1.1 ) 106 Providing and fixing wire gauge shutters using galvanized M.S. wire gauge of average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm, for doors, windows and clerestory windows with hinges and necessary screws :35 mm thick shutters (DSR 9.27.1) With ISI marked stainless steel butt hinges of required size 9.27.1.2 Second class teak wood (DSR 9.27.1.2.1) 107 Providing and fixing wire gauge shutters using galvanized M.S. wire gauge of average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm, for doors, windows and clerestory windows with hinges and necessary screws :30 mm thick shutters (DSR 9.27.2) with ISI marked M.S. pressed butt hinges bright finished of required size 9.27.2.1 Second class teak wood (DSR 9.27.2.1.1) 108 Providing and fixing wire gauge shutters using galvanized M.S. wire gauge of average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm, for doors, windows and clerestory windows with hinges and necessary screws :30 mm thick shutters (DSR 9.27.2) With ISI marked stainless steel butt hinges of required size 9.27.2.2 Second class teak wood (DSR 9.27.2.2.1) 109 Providing and fixing wooden moulded beading to door and window frames with iron screws, plugs and priming coat on unexposed surface etc. complete : (DSR 9.4) 2nd class teak wood 9.40.1 50x12 mm (DSR 9.40.1.1) 110 Providing and fixing wooden moulded beading to door and window frames with iron screws, plugs and priming coat on unexposed surface etc. complete : (DSR 9.4) 2nd class teak wood 9.40.1 50 x 20 mm (DSR 9.40.1.2) 111 Providing and fixing wooden moulded beading to door and window frames with iron screws, plugs and priming coat on unexposed surface etc. complete : (DSR 9.4) Kiln seasoned and chemically treated hollock wood 9.40.2 50x12 mm (DSR 9.40.2.1) 112 Providing and fixing wooden moulded beading to door and window frames with iron screws, plugs and priming coat on unexposed surface etc. complete : (DSR 9.4) Kiln seasoned and chemically treated hollock wood 9.40.2 50x20 mm (DSR 9.40.2.2) 113 Providing and fixing nickel plated M.S. pipe curtain rods with nickel plated brackets : (DSR 9.47) 20 mm dia (heavy type) (DSR 9.47.1) 114 Providing and fixing nickel plated M.S. pipe curtain rods with nickel plated brackets : (DSR 9.47) 25 mm dia (heavy type) (DSR 9.47.2) 115 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. (DSR 9.48) Fixed to steel windows by welding (DSR 9.48.1) 116 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. (DSR 9.48) Fixed to openings /wooden frames with rawl plugs screws etc. (DSR 9.48.2) 117 Providing and fixing ISI marked, IS : 1341, M.S. heavy weight bright finished butt hinges with necessary screws etc. complete : (DSR 9.56) 125x90x4.00 mm (DSR 9.56.1) 118 Providing and fixing ISI marked, IS : 1341, M.S. heavy weight bright finished butt hinges with necessary screws etc. complete : (DSR 9.56) 100x75x3.50 mm (DSR 9.56.2) 119 Providing and fixing ISI marked, IS : 1341, M.S. heavy weight bright finished butt hinges with necessary screws etc. complete : (DSR 9.56) 75x60x3.10 mm (DSR 9.56.3) 120 Providing and fixing ISI marked IS:1341 oxidised M.S. pressed butt hinges with necessary screws etc. complete. (Copper oxidised as per IS 1378) (DSR 9.57) 125x65x2.12 mm (DSR 9.57.1) 121 Providing and fixing ISI marked IS:1341 oxidised M.S. pressed butt hinges with necessary screws etc. complete. (Copper oxidised as per IS 1378) (DSR 9.57) 100x58x1.90 mm (DSR 9.57.2) 122 Providing and fixing ISI marked IS:1341 oxidised M.S. pressed butt hinges with necessary screws etc. complete. (Copper oxidised as per IS 1378) (DSR 9.57) 75x47x1.70 mm (DSR 9.57.3) 123 Providing and fixing ISI marked oxidised M.S. single acting spring hinges with necessary screws etc. complete (Copper oxidised as per IS 1378) (DSR 9.59) 150 mm (DSR 9.59.1) 124 Providing and fixing ISI marked oxidised M.S. single acting spring hinges with necessary screws etc. complete (Copper oxidised as per IS 1378) (DSR 9.59) 125 mm (DSR 9.59.2) 125 Providing and fixing ISI marked oxidised M.S. single acting spring hinges with necessary screws etc. complete (Copper oxidised as per IS 1378) (DSR 9.59) 100 mm (DSR 9.59.3) 126 Providing and fixingISI marked IS: 453 oxidised M.S. double acting spring hinges with necessary screws etc. complete (Copper oxidised as per IS 1378) (DSR 9.6) 150 mm (DSR 9.60.1) 127 Providing and fixingISI marked IS: 453 oxidised M.S. double acting spring hinges with necessary screws etc. complete (Copper oxidised as per IS 1378) (DSR 9.6) 125 mm (DSR 9.60.2) 128 Providing and fixingISI marked IS: 453 oxidised M.S. double acting spring hinges with necessary screws etc. complete (Copper oxidised as per IS 1378) (DSR 9.6) 100 mm (DSR 9.60.3) 129 Providing and fixing ISI marked oxidised M.S. sliding door bolts with nuts and screws etc. complete (Copper oxidised as per IS 1378) (DSR 9.62) 300x16 mm (DSR 9.62.1) 130 Providing and fixing ISI marked oxidised M.S. sliding door bolts with nuts and screws etc. complete (Copper oxidised as per IS 1378) (DSR 9.62) 250x16 mm (DSR 9.62.2) 131 Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete (Copper oxidised as per IS 1378) (DSR 9.63) 250x10 mm (DSR 9.63.1) 132 Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete (Copper oxidised as per IS 1378) (DSR 9.63) 200x10 mm (DSR 9.63.2) 133 Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete (Copper oxidised as per IS 1378) (DSR 9.63) 150x10 mm (DSR 9.63.3) 134 Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete (Copper oxidised as per IS 1378) (DSR 9.63) 100x10 mm (DSR 9.63.4) 135 Providing and fixing ISI marked 85x42 mm oxidised M.S. pull bolt lock conforming to IS : 7534 with necessary screws bolts, nut and washers etc. complete (Copper oxidised as per IS 1378). (DSR )(DSR 9.64) 136 Providing and fixing ISI marked oxidised M.S. door latches conforming to IS:5930 with screws etc. complete (Copper oxidised as per IS 1378) (DSR 9.65) 300x20x6 mm (DSR 9.65.1) 137 Providing and fixing ISI marked oxidised M.S. door latches conforming to IS:5930 with screws etc. complete (Copper oxidised as per IS 1378) (DSR 9.65) 250x20x6 mm (DSR 9.65.2) 138 Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete (Copper oxidised as per IS 1378) (DSR 9.66) 125 mm (DSR 9.66.1) 139 Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete (Copper oxidised as per IS 1378) (DSR 9.66) 100 mm (DSR 9.66.2) 140 Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete (Copper oxidised as per IS 1378) (DSR 9.66) 75 mm (DSR 9.66.3) 141 Providing and fixing oxidised M.S. hasp and staple (safety type) conforming to IS : 363 with necessary screws etc. complete (Copper oxidised as per IS 1378) (DSR 9.67) 150 mm (DSR 9.67.1) 142 Providing and fixing oxidised M.S. hasp and staple (safety type) conforming to IS : 363 with necessary screws etc. complete (Copper oxidised as per IS 1378) (DSR 9.67) 115 mm (DSR 9.67.2) 143 Providing and fixing oxidised M.S. hasp and staple (safety type) conforming to IS : 363 with necessary screws etc. complete (Copper oxidised as per IS 1378) (DSR 9.67) 90 mm (DSR 9.67.3) 144 Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete : (DSR 9.7) 125x64x1.90 mm (DSR 9.70.1) 145 Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete : (DSR 9.7) 100X58X1.90 mm (DSR 9.70.2) 146 Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete : (DSR 9.7) 75x47x1.80 mm (DSR 9.70.3) 147 Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete : (DSR 9.7) 50x37x1.50 mm (DSR 9.70.4) 148 Providing and fixing IS : 12817 marked stainless steel butt hinges (heavy weight) with stainless steel screws etc. complete : (DSR 9.71) 125x64x2.50 mm (DSR 9.71.1) 149 Providing and fixing IS : 12817 marked stainless steel butt hinges (heavy weight) with stainless steel screws etc. complete : (DSR 9.71) 100x60x2.50 mm (DSR 9.71.2) 150 Providing and fixing IS : 12817 marked stainless steel butt hinges (heavy weight) with stainless steel screws etc. complete : (DSR 9.71) 75x50x2.50 mm (DSR 9.71.3) 151 Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete : (DSR 9.74) 250x10 mm (DSR 9.74.1) 152 Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete : (DSR 9.74) 200x10 mm (DSR 9.74.2) 153 Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete : (DSR 9.74) 150x10 mm (DSR 9.74.3) 154 Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete : (DSR 9.74) 100x10 mm (DSR 9.74.4) 155 Providing and fixing bright finished brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. (DSR )(DSR 9.76) 156 Providing and fixing bright finished brass 100 mm mortice latch with one dead bolt and a pair of lever handles of approved quality with necessary screws etc. complete. (DSR )(DSR 9.77) 157 Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. (DSR )(DSR 9.83) 158 Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISi, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete. (DSR )(DSR 9.84) 159 Providing and fixing bright finished brass hasp and staple (safety type) with necessary screws etc. complete : (DSR 9.87) 150 mm (DSR 9.87.1) 160 Providing and fixing bright finished brass hasp and staple (safety type) with necessary screws etc. complete : (DSR 9.87) 115 mm (DSR 9.87.2) 161 Providing and fixing bright finished brass hasp and staple (safety type) with necessary screws etc. complete : (DSR 9.87) 90 mm (DSR 9.87.3) 162 Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. (DSR )(DSR 9.88) 163 Providing and fixing chromium plated brass night latch of approved quality including necessary screws etc. complete. (DSR )(DSR 9.89) 164 Providing and fixing special quality chromium plated brass cupboard locks with six levers of approved quality including necessary screws etc. complete. (DSR 9.9) Size 40 mm (DSR 9.90.1) 165 Providing and fixing special quality chromium plated brass cupboard locks with six levers of approved quality including necessary screws etc. complete. (DSR 9.9) Size 50 mm (DSR 9.90.2) 166 Providing and fixing special quality chromium plated brass cupboard locks with six levers of approved quality including necessary screws etc. complete. (DSR 9.9) Size 65 mm (DSR 9.90.3) 167 Providing and fixing special quality chromium plated brass cupboard locks with six levers of approved quality including necessary screws etc. complete. (DSR 9.9) Size 75 mm (DSR 9.90.4) 168 Providing and fixing chromium plated brass 50 mm cupboard or wardrobe knobs with nuts complete. (DSR )(DSR 9.91) 169 Providing and fixing chromium plated brass handles with necessary screws etc. complete: (DSR 9.92) 125 mm (DSR 9.92.1) 170 Providing and fixing chromium plated brass handles with necessary screws etc. complete: (DSR 9.92) 100 mm (DSR 9.92.2) 171 Providing and fixing chromium plated brass handles with necessary screws etc. complete: (DSR 9.92) 75 mm (DSR 9.92.3) 172 Providing and fixing chromium plated brass casement window fastener with necessary screws etc. complete. (DSR )(DSR 9.93) 173 Providing and fixing ISI marked aluminium butt hinges anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade with necessary screws etc. complete: (DSR 9.95) 125x63x4 mm (DSR 9.95.2) 174 Providing and fixing ISI marked aluminium butt hinges anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade with necessary screws etc. complete: (DSR 9.95) 100x63x3.2 mm (DSR 9.95.5) 175 Providing and fixing ISI marked aluminium butt hinges anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade with necessary screws etc. complete: (DSR 9.95) 75x63x3.2 mm (DSR 9.95.7) 176 Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : (DSR 9.96) 300x16 mm (DSR 9.96.1) 177 Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : (DSR 9.96) 250x16 mm (DSR 9.96.2) 178 Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : (DSR 9.97) 300x10 mm (DSR 9.97.1) 179 Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : (DSR 9.97) 250x10 mm (DSR 9.97.2) 180 Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : (DSR 9.97) 200x10 mm (DSR 9.97.3) 181 Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : (DSR 9.97) 150x10 mm (DSR 9.97.4) 182 Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : (DSR 9.97) 100x10 mm (DSR 9.97.5) 183 Providing and fixing aluminium pull bolt lock, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws bolts, nut and washers etc. complete. (DSR )(DSR 9.98) 184 Providing and fixing 50 cm long aluminium kicking plate of size 100x3.15 mm, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete. (DSR )(DSR 9.99) 185 Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : (DSR 9.1) 125 mm (DSR 9.100.1) 186 Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : (DSR 9.1) 100 mm (DSR 9.100.2) 187 Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : (DSR 9.1) 75 mm (DSR 9.100.3) 188 Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. (DSR 9.101) Single rubber stopper (DSR 9.101.1) 189 Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. (DSR 9.101) Twin rubber stopper (DSR 9.101.2) 190 Providing and fixing bright finished brass 100 mm mortice latch and lock, ISI marked, with six levers and a pair of anodised (anodic coating not less than grade AC 10 as per IS : 1868) aluminium lever handles of approved quality with necessary screws etc. complete. (DSR )(DSR 9.103) 191 Providing and fixing aluminium tee channels (heavy duty) with rollers & stop end in pelmets as curtain rod. (DSR )(DSR 9.104) 192 Providing and fixing Bamboo jaffery/ fencing consisting of superior quality 25mm dia (Average) half cut bamboo placed vertically and fixed together with three numbers horizontal running members of hollock wood in scantling of section 50X25 mm, fixed with nails and G.I wire on existing support complete as per direction of Engineer-in-charge. (DSR )(DSR 9.110) 193 Providing and fixing magnetic catcher of approved quality in cupboard / ward robe shutters, including fixing with necessary screws etc. complete. (DSR 9.114) Triple strip vertical type (DSR 9.114.1) 194 Providing and fixing magnetic catcher of approved quality in cupboard / ward robe shutters, including fixing with necessary screws etc. complete. (DSR 9.114) Double strip (horizontal type) (DSR 9.114.2) 195 Providing and fixing powder coated telescopic drawer channels 300 mm long with necessary screws etc. complete as per directions of Engineer- in-charge. (DSR )(DSR 9.115) 196 Providing and fixing sliding arrangement in racks/ cupboards/cabinets shutter by with stainless steel rollers to run inside C or E aluminium channel section (The payment of C or E channel shall be made separately) (DSR )(DSR 9.116) 197 Providing and fixing 12 mm thick panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick. (DSR 9.126) Marine plywood conforming to IS: 710 (DSR 9.126.1) 198 Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality. (DSR 9.127) 1.5 mm thick (DSR 9.127.1) 199 Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality. (DSR 9.127) 1.0 mm thick (DSR 9.127.2) 200 Providing and fixing cup board shutters 25 mm thick, with Pre-laminated flat pressed three layer particle board or graded wood particle board IS: 12823 marked, exterior grade (Grade l Type ll), having one side decorative lamination and other side balancing lamination, including IInd class teak wood lipping of 25 mm wide x12 mm thick with necessary screws and bright finished stainless steel piano hinges, complete as per direction of the Engineer-in-Charge (DSR )(DSR 9.129) 201 Providing and fixing wire gauge shutters using stainless steel grade 304 wire gauge with wire of dia 0.5 mm and average width of aperture 1.4 mm in both directions for doors, windows and clerestory windows with necessary screws :30 mm thick shutters (DSR 9.134.2) With ISI marked stainless steel butt hinges of required size 9.134.2.2 Second class teak wood (DSR 9.134.2.2.1 ) 202 Providing and fixing fly proof stainless steel grade 304 wire gauge, to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.50 mm all complete. (DSR 9.135) With 2nd class teak wood beading 62X19 mm (DSR 9.135.1) 203 Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete. (DSR 9.165) 125 mm (DSR 9.165.1) 204 Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete. (DSR 9.165) 100mm (DSR 9.165.2) 205 Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete. (DSR 9.165) 75 mm (DSR 9.165.3) 206 Providing and fixing 18mm thick both sides Pre-laminated cement bonded wood particle board as per IS : 15786:2008 of approved brand and shade with suitable full threaded steel screws etc. in partitions, boxes, shelves, racks and cupboard, kitchen cabinet under kitchen counter etc. all complete as per direction of Engineer-in-charge (Note: Fittings to be paid separately). (DSR 9.166) 18 mm thick (DSR 9.166.1) 207 Providing and fixing 6mm thick both sides Pre-laminated cement bonded wood particle board as per IS : 15786:2008 of approved brand and shade with suitable full threaded steel screws etc. on the backing of racks, drawer, cupboard, kitchen cabinet under kitchen counter etc. all complete as per direction of Engineer-in-charge. (DSR )(DSR 9.167) 208 Providing and fixing cupboard shutter with 19mm thick one side decorative and other side balancing lamination factory pressed BWP grade marine ply as per IS 710 of approved brand including 2mm thick PVC edge banding tape with hot glue by edge bending machine etc. with auto closing spring loaded hinges (hydraulic type) etc. complete as per direction of Engineer-in-charge.(Payment of providing and fixing auto closing hinges shall be paid separately)(DSR )(DSR 9.168) 209 Providing and fixing 19mm thick both side balancing lamination factory pressed BWP grade marine ply as per IS 710 of approved brand boxes,shelves,racks,almirah,cupboard and drawer etc. including necessary nails,screws etc.complete as per direction of Engineer-in-charge.(DSR )(DSR 9.169) 210 Providing and fixing stainless steel fancy handle of approved make fixed with SS screws etc. complete as per direction of Engineer-in-charge. (DSR 9.17) 200 mm (DSR 9.170.1) 211 Providing and fixing stainless steel soft closing spring hinges at 0 degree hinges (hydraulic type) of approved make/brand to cupboard shutters with full threaded steel screws including making necessary recess in board and finished etc. complete as per direction of Engineer-in-charge. (DSR )(DSR 9.171) 212 Providing and fixing stainless steel soft closing heavy type telescopic drawer channels of approved make 500 mm long with screws etc. complete as per directions of Engineer- in-charge. (DSR )(DSR 9.172) 213 Providing and fixing ready made 304 grade stainless steel Modular kitchen basket and accessories such as right angle basket (Plain Cup & Saucer, plant, Partition, Bottle rack, Thali, Cutlery) kitchen utensilbasket, Dinner set basket, kitchen grain basket, Multipurpose basket as per site requirement including finishing (wherever required) and fittings. The same shall be fixed with necessary stainless steel nuts & bolts, Stainless Steel screws & telescopic channel etc. as per direction of Engineer-in-charge. (For payment purpose only weight of Stainless steel basket shall be considered excluding weight of all fixing accessories such as nuts, bolts, fasteners telescopic basket channels etc. Payment of providing and fixing telescopic channel shall be paid separately) (DSR )(DSR 9.173) 214 Providing and fixing 2mm thick 16 to 19mm wide PVC edge binding tape of approved quality for cupboard/wardrobe shutters including necessary synthetic resin hot pressed to edges on binding machine etc. complete as per directions of Engineer- in-charge. (DSR )(DSR 9.174) 215 Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. (DSR )(DSR 10.1) 216 Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. (DSR )(DSR 10.2) 217 Fixing standard steel glazed doors, windows and ventilators in walls, including fixing of float glass panes with glazing clips and special metal-sash putty of approved make, or metal beading with screws, (only steel windows, glass panes cut to size and glazing clips or metal beading with screws, shall be supplied by department free of cost. (DSR 10.1) Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) (DSR 10.10.1) 218 Fixing standard steel glazed doors, windows and ventilators in walls, including fixing of float glass panes with glazing clips and special metal-sash putty of approved make, or metal beading with screws, (only steel windows, glass panes cut to size and glazing clips or metal beading with screws, shall be supplied by department free of cost. (DSR 10.1) Fixing with carbon steel galvanised dash fastener of required dia and size (to be paid for separately) (DSR 10.10.2) 219 Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. (DSR 10.15) Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) (DSR 10.15.1) 220 Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. (DSR 10.15) Fixing with carbon steel galvanised dash fastener of required dia and size (to be paid for separately) (DSR 10.15.2) 221 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. (DSR 10.16) Electric resistance or induction butt welded tubes (DSR 10.16.3) 222 Providing and fixing M.S. fan clamp type I or II of 16 mm dia M.S. bar, bent to shape with hooked ends in R.C.C. slabs or beams during laying, including painting the exposed portion of loop, all as per standard design complete. (DSR )(DSR 10.17) 223 Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing. (DSR )(DSR 10.18) 224 Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. (DSR 10.25) In stringers, treads, landings etc. of stair cases, including use of chequered plate wherever required, all complete (DSR 10.25.1) 225 Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. (DSR 10.25) In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works (DSR 10.25.2) 226 Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. (DSR 10.26) M.S. tube (DSR 10.26.1) 227 Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. (DSR 10.26) E.R.W. tubes (DSR 10.26.2) 228 Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). (DSR )(DSR 10.28) 229 Providing & fixing fly proof wire gauze to windows, clerestory windows & doors with M.S. Flat 15x3 mm and nuts & bolts complete. (DSR 10.29) Stainless steel (grade 304) wire gauze of 0.5 mm dia wire and 1.4 mm aperture on both sides (DSR 10.29.2) 230 Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : (DSR 10.3) 4.0 mm thick glass panes (DSR 10.30.1) 231 Providing and fixing angle iron frames for doors, windows and ventilators of mild steel Angle sections of size 35x35x5 mm, joints mitred and welded by angle iron 35x35x5 mm or 35x 5 mm flat pieces to the existing T-iron frame or to the wall with dash fastener,including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer, all complete as per the direction of Engineer-In-charge. (DSR )(DSR 10.31) 232 Brick on edge flooring with bricks of class designation 7.5 on a bed of 12 mm cement mortar, including filling the joints with same mortar, with common burnt clay non modular bricks: (DSR 11.1) 1:4 (1 cement : 4 coarse sand) (DSR 11.1.1) 233 Brick on edge flooring with bricks of class designation 7.5 on a bed of 12 mm cement mortar, including filling the joints with same mortar, with common burnt clay non modular bricks: (DSR 11.1) 1:6 (1cement : 6 coarse sand) (DSR 11.1.2) 234 Dry brick on edge flooring in required pattern with bricks of class designation 7.5 on a bed of 12 mm mud mortar, including filling joints with Jamuna sand, with common burnt clay non modular bricks. (DSR )(DSR 11.2) 235 Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. (DSR 11.3) 40 mm thick with 20 mm nominal size stone aggregate (DSR 11.3.1) 236 Cement plaster skirting up to 30 cm height, with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement. (DSR 11.6) 18 mm thick (DSR 11.6.1) 237 Cement concrete pavement with 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete. (DSR )(DSR 11.7) 238 Providing and fixing glass strips in joints of terrazo/ cement concrete floors. (DSR ) 40 mm wide and 4 mm thick (DSR 11.13.1) 239 Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand). (DSR 11.2) Dark shade pigment using ordinary cement (DSR 11.20.3) 240 Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand). (DSR 11.2) Ordinary cement without any pigment (DSR 11.20.4) 241 Providing and fixing 10 mm thick acid and/or alkali resistant tiles of approved make and colour using acid and/or alkali resisting mortar bedding, and joints filled with acid and/or alkali resisting cement as per IS : 4457, complete as per the direction of Engineer-in- Charge. (DSR 11.21) In flooring on a bed of 10 mm thick mortar 1:4 (1 acid proof cement : 4 coarse sand) 11.21.1 Acid and alkali resistant tile (DSR 11.21.1.1) 242 Providing and fixing 10 mm thick acid and/or alkali resistant tiles of approved make and colour using acid and/or alkali resisting mortar bedding, and joints filled with acid and/or alkali resisting cement as per IS : 4457, complete as per the direction of Engineer-in- Charge. (DSR 11.21) In dado/skirting on 12 mm thick mortar 1:4 (1 acid proof cement : 4 coarse sand) 11.21.2 Acid and alkali resistant tile (DSR 11.21.2.1) 243 Marble stone flooring with 18 mm thick marble stone, as per sample of marble approved by Engineer-in-charge, over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with grey cement slurry, including rubbing and polishing complete with : (DSR 11.23) Udaipur green marble (DSR 11.23.5) 244 Extra for pre finished nosing to treads of steps of marble stone. (DSR )(DSR 11.24) 245 Extra for marble stone flooring in treads of steps and risers using single length up to 2.00 metre. (DSR )(DSR 11.25) 246 Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : (DSR 11.26) 25 mm thick (DSR 11.26.1) 247 Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. (DSR )(DSR 11.27) 248 40 mm thick fine dressed stone flooring over 20 mm (average) thick base of cement mortar 1:5 (1 cement : 5 coarse sand) with joints finished flush. (DSR 11.28) Red sand stone (DSR 11.28.1) 249 Extra for Kota stone/ sand stone in treads of steps and risers using single length above normal size up to 2.00 metre. (DSR )(DSR 11.32) 250 Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete. (DSR )(DSR 11.37) 251 Providing and fixing 1st quality ceramic glazed floor tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. (DSR )(DSR 11.37A) 252 Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sq.m including pointing the joints with white cement and matching pigments etc., complete. (DSR )(DSR 11.38) 253 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqmincluding grouting the joints with white cement and matching pigments etc., complete. (DSR 11.41) Size of Tile 600x600 mm (DSR 11.41.2) 254 Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer)with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand)jointing with grey cement slurry @3.3 kg/sqm including grouting thejoints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only .Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. (DSR 11.41A) Double charge vitrified tile polished finish of size 11.41A.1 Size of Tile 600 x 600 mm (DSR 11.41A.1.1) 255 Providing and laying 500x500x40 mm thick Turf paver (Turfpave XD) on 150 mm thick sub grade of compacted bed of 20 mm thick nominal size stone aggregate and base course and filling with 150 mm thick jamuna sand, including spreading, well ramming, consolidating and finishing smooth etc. all complete as per direction of Engineer-in-charge. (DSR )(DSR 11.45) 256 Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge. (DSR 11.48) Size of Tile 600x600 mm (DSR 11.48.2) 257 Providing and laying full body vitrified tile in floor of minimum thickness 15 mm with water absorption less than 0.06% and conforming to IS:15622, of approved make, brand and manufacturer, laid on 20 mm thick base cement mortar 1:4 (1 cement: 4 coarse sand)jointing with grey cement slurry @3.30 kg / sqm including grouting thejoints with white cement and matching pigments etc. The slab must be cut with the zero chipping diamond cutter only.Laying of slab will be done with the help of notch trowel, wedge, clips of required thickness, vacuum cups for lifting, leveling system and rubber mallet for placing the slab gently and easily. Size of tile 800x2400mm of all colours and shades.(DSR )(DSR 11.49A) 258 Deduct for not grouting the joints with white cement and matching pigment in the items of fixing of vitrified tiles. (DSR )(DSR 11.50) 259 Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. (DSR 12.42) Coupler 12.42.1 75 mm (DSR 12.42.1.1) 260 Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. (DSR 12.42) Coupler 12.42.1 110 mm (DSR 12.42.1.2) 261 Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturers specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : (DSR 12.45) 12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- (Part I) :2011 (Board with BIS certification marks) (DSR 12.45.1) 262 Providing & fixing UV stabilised fiberglass reinforced plastic sheet roofing up to any pitch, including fixing with polymer coated J or L hooks, bolts & nuts 8mm dia. G.I plain/bitumen washers complete but excluding the cost of purlins, rafters, trusses etc. The sheets shall be manufactured out of 2400 TEX panel rovigs incorporating minimum 0.3% ultra-violet stabiliser in resin system under approximately 2400 psi and hot cured. They shall be of uniform pigmentation and thickness without air pockets and shall conform to IS 10192 and IS 12866.The sheets shall be opaque or translucent, clear or pigmented, textured or smooth as specified. (DSR 12.47) 2 mm thick flat (DSR 12.47.2) 263 Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main T runner with suitably spacedjoints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross T of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main T at 600 mm center to center to form a grid of 1200x600 mm and secondary cross T of length 600 mm and size 24x25 mm made of0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main T runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. (DSR 12.52) 12.5 mm thick fully Perforated Gypsum Board tile made from plasterboard having glass fibre conforming to IS: 2095 part I, of size 595x595 mm, having perforation of 9.7x9.7 mm at 19.4 mm c/c with center borders of 48 mm and the side borders of 30 mm, backed with non woven tissue on the back side, having an NRC (Noise Reduction Coefficient) of 0.79, with 50 mm resin bonded glass wool backing. (DSR 12.52.4) 264 Providing and fixing tiled false ceiling of specifiedmaterials of size 595x595 mm in true horizontal level, suspended on interlocking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main T runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross T of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main T at 600 mm center to center to form a grid of 1200x600 mm and secondary cross T of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main T runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanized butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. (DSR 12.58) 8 mm thick fully perforated calcium silicate board made with Calcareous & Siliceous materials reinforced with cellulose fiber manufactured through autoclaving process to give stable crystalline structure with minimum compressive strength 225 kg/ sq. cm, bending strength 100 kg/sq. cm , of size 595x595 mm, having perforation of dia. 10 mm with minimum perforated area 18 % with non woven tissue on the back side, having an NRC ( Noise Reduction Coefficient) of 0.85, with 50 mm thick rockwool of 48 kg /cum backing. (DSR 12.58.1) 265 Providing & fixing false ceiling at all height including providing & fixing of framework made of special section, power pressed from M.S. sheets and galvanised with zinc coating of 120 gms/ sqm (both side inclusive) as per IS : 277 and consisting of angle cleat of size 25mm wide x 1.6mm thick with flanges of 27mm and 37mm, at 1200mm c/c, one flange fixed to the ceiling with dash fastener 12.5mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25 x10 x0.50mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I chanels 45 x15 x 0.90mm running at the spacing of 1200 mm c/c, to which the ceiling section 0.5mm thick bottom wedge of 80mm with tapered flanges of 26 mm each having lips of 10.5mm, at 450mm c/c, shall be fixed in a direction perpendicular to G.I intermediate channel with connecting clip made out of 2.64mm dia x 230mm long G.I wire at every junction, including fixing perimeter channels 0.50mm thick 27mm high having flanges of 20mm and 30mm long, the perimeter of ceiling fixed to wall/ partitions with the help of Rawl plugs at 450mm centre, with 25mm long dry wall screws @ 230mm interval, including fixing of Calcium Silicate Board to ceiling section and perimeter channels with the help of dry wall screws of size 3.5 x25mm at 230mm c/c, including jointing & finishing to a flush finish of tapered and square edges of the board with recommended jointing compounds, jointing tapes,finishing with jointing compounds in three layers covering up to 150mm on both sides of joints and two coats of primer suitable for boards, all as per manufactures specification and also including the cost of making opening for light fittings, grills, diffusers, cut outs made with frame of perimeter channels suitably fixed, all complete as per drawings, specificaton and direction of the Engineer in charge but excluding the cost of painting with: (DSR 12.59) 8 mm thick Calcium Silicate Board made with Calcareous & Siliceous materials reinforced with cellulose fiber manufactured through autoclaving process. (DSR 12.59.1) 266 Providing & fixing at all heights, levels and locations Mill finish Aluminium alloy roofing sheets of alloyIS designation31500, temper Hx8 conforming to IS 737 and dimensions as per IS code 2676 with characteristics of good formability and corrosion resistance. The profile sheets shall be fixed to truss members in slope or required pitch or curvature with Hex cap headed self drilling/tapping Stainless steel screws M6, 50 mm long with 3 mm EPDM seal washer etc. all inclusive of labour, scaffolding, T&P and sundries etc. complete as per directions of the Engineer-In-Charge. (Cost of truss/frame work shall be paid separately). (DSR 12.64) 0.56 mm, Aluminium troughed profile with center to center pitch of 200 mm, depth of 32 mm, overall profile width1092 mm, cover width 1000mm. (DSR 12.64.1) 267 Providing and fixing of Pre-coated colour or mill finishAluminium Roofing Accessories in 0.71 mm thickness ,Alloy 31500 (IS designation) [Aluminium Alloy (AA) 3004 (ISO designation)]For color, coating shall be 5-7 microns epoxy primer on both sides of the sheet and polyester top coat 15-18 microns, using self drilling/tapping SS screws of size 6 x 50mm with 3mm thick EPDM seal and SS plain washer complete : (DSR 12.66) Precoated/mill finish aluminium Ridges plain (500- 600mm) (DSR 12.66.1) 268 Providing and fixing of Pre-coated colour or mill finishAluminium Roofing Accessories in 0.71 mm thickness ,Alloy 31500 (IS designation) [Aluminium Alloy (AA) 3004 (ISO designation)]For color, coating shall be 5-7 microns epoxy primer on both sides of the sheet and polyester top coat 15-18 microns, using self drilling/tapping SS screws of size 6 x 50mm with 3mm thick EPDM seal and SS plain washer complete : (DSR 12.66) Precoated/mill finish aluminium Crimp curve (DSR 12.66.5) 269 Providing and fixing of Pre-coated colour or mill finishAluminium Roofing Accessories in 0.71 mm thickness ,Alloy 31500 (IS designation) [Aluminium Alloy (AA) 3004 (ISO designation)]For color, coating shall be 5-7 microns epoxy primer on both sides of the sheet and polyester top coat 15-18 microns, using self drilling/tapping SS screws of size 6 x 50mm with 3mm thick EPDM seal and SS plain washer complete : (DSR 12.66) Precoated/mill finish aluminium Gutter (600 mm over all girth) (DSR 12.66.6) 270 12 mm cement plaster of mix :CEMENT PLASTER (IN COARSE SAND) (DSR 13.4) 1:4 (1 cement: 4 coarse sand) (DSR 13.4.1) 271 12 mm cement plaster of mix :CEMENT PLASTER (IN COARSE SAND) (DSR 13.4) 1:6 (1 cement: 6 coarse sand) (DSR 13.4.2) 272 12 mm cement plaster finished with a floating coat of neat cement of mix : (DSR 13.7) 1:4 (1 cement: 4 fine sand) (DSR 13.7.2) 273 6 mm cement plaster of mix : (DSR 13.16) 1:3 (1 cement : 3 fine sand) (DSR 13.16.1) 274 Neat cement punning. (DSR )(DSR 13.18) 275 Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers. (DSR )(DSR 13.21) 276 Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour : (DSR 13.41) New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than50 gram/litre (DSR 13.41.1) 277 Finishing walls with Acrylic Smooth exterior paint of required shade : (DSR 13.46) New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) (DSR 13.46.1) 278 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: (DSR 13.47) New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) (DSR 13.47.1) 279 Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : (DSR 13.48) Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of Special primer applied @ 0.75 ltr /10 sqm (DSR 13.48.1) 280 Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : (DSR 13.48) Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/10 sqm of approved brand and manufacture (DSR 13.48.2) 281 Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : (DSR 13.48) Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture (DSR 13.48.3) 282 Finishing walls with ready mixed Premium acrylic emulsion paint (Company Depot Tinted) having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shadewith silicon additives. (DSR 13.48A) New work (Two or more coats applied @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm. (DSR 13.48A.1) 283 Coal tarring two coats on new work using 0.16 Litre and 0.12 litre coal tar per sqm in the first coat and second coat respectively. (DSR )(DSR 13.59) 284 Lettering with black Japan paint of approved brand and manufacture (DSR )(DSR 13.71) 285 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. (DSR )(DSR 13.80) 286 Distempering with 1st quality acrylic distemper (ready mixed) having VOC (Volatile Organic Compound ) content less than 50 gram/ litre, of approved brand and manufacturerincluding applying additional coats wherever required to achieve even shade and colour(DSR 13.81) Old work (one or more coats) (DSR 13.81.1) 287 Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. (DSR 13.82) One coat (DSR 13.82.1) 288 Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. (DSR 13.82) Two coats (DSR 13.82.2) 289 Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. (DSR 13.83) One coat (DSR 13.83.1) 290 Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. (DSR 13.83) Two coats (DSR 13.83.2) 291 Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content. (DSR 13.85) With ready mixed pink or grey primer on wood work (hard and soft wood) having VOC content less than 50 grams/ litre (DSR 13.85.1) 292 Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content. (DSR 13.85) With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre (DSR 13.85.3) 293 White washing with lime to give an even shade : (DSR 13.87) Old work (two or more coats) (DSR 13.87.1) 294 White washing with lime to give an even shade : (DSR 13.87) Old work (one or more coats) (DSR 13.87.2) 295 Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete (DSR )(DSR 13.88) 296 Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. (DSR )(DSR 13.91) 297 Painting with oil type wood preservative of approved brand and manufacture: (DSR 13.97) Old work (one or more coats) (DSR 13.97.1) 298 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : (DSR 13.99) One or more coats on old work (DSR 13.99.1) 299 Re-lettering with black Japan paint of approved brand and manufacture. (DSR )(DSR 13.105) 300 Painting (one or more coats) with black Japan paint of approved brand and manufacture to give an even shade. (DSR )(DSR 13.106) 301 Finishing walls with textured exterior paint of required shade : (DSR 13.11) Old work (One or more coats) applied @ 1.82 ltr/10 sqm. (DSR 13.110.2) 302 Finishing walls with Acrylic Smooth exterior paint of required shade : (DSR 13.111) Old work (Two or more coat applied @ 1.67 ltr/ 10 sqm) on existing cement paint surface (DSR 13.111.1) 303 Finishing walls with Acrylic Smooth exterior paint of required shade : (DSR 13.111) Old work (One or more coat applied @ 0.90 ltr/10 sqm). (DSR 13.111.2) 304 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade (DSR 13.112) Old work (Two or more coats applied @ 1.43 ltr/ 10 sqm) over existing cement paint surface (DSR 13.112.1) 305 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade (DSR 13.112) Old work (one or more coats applied @ 0.83 ltr/10 sqm). (DSR 13.112.2) 306 Varnishing with varnish of approved brand and manufacture: (DSR 13.113) One or more coats with copal varnish (DSR 13.113.1) 307 Melamine polishing on wood work (one or more coat). (DSR )(DSR 13.114) 308 Polishing in high gloss/matt finish melamine clear polish on wood work in required color/wooden shade texture with following process in the sequence as detailed below:1.The surface to be polished is rubbed with sand paper 80/120 no. and then with sand paper of 160/180 nos.2. Applying two coats of sealer with spray gun and allowing sufficient drying time for 1st coat and 2nd coat is allowed to dry for 8 to 12 hrs.3. On drying of sealer coat, wet rubbing with emery cloth of finer grading with ample water to remove excess sealer layer and make the surface further smooth after this wet rubbing, then surface is applied with special grade melamine fillers to fill all the small and big holes/grooves etc. Filler coat to be allowed to dry for 4 to 6 hrs on which again a light wet rubbing is done this surface is further allowed to dry for 12 hrs.4. On this, 1st coat of melamine polish is applied with spray gun using melamine clear polish and melamine thinner in required proportion. This 1st coat is allowed to dry for 24 hrs then this dry surface is again fine wet rubbed smooth, which is further allowed to dry for 12 hrs. The final melamine polish is applied with compressor pressure spray gun using melamine clear polish and melamine thinner mixed in required proportion complete as per direction of Engineer-in-Charge. (Final coat to be done in 1 or 2 layers without gap of time.) (DSR )(DSR 13.116) 309 Fixing chowkhats in existing opening including embedding chowkhats in floors or walls cutting masonry for holdfasts, embedding hold fasts in cement concrete blocks of size 15 x 10 x 10 cm with cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size), painting two coats of approved wood preservative to sides of chowkhats and making good the damages to walls and floors as required complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge. (DSR 14.2) Door chowkhats (DSR 14.2.1) 310 Fixing chowkhats in existing opening including embedding chowkhats in floors or walls cutting masonry for holdfasts, embedding hold fasts in cement concrete blocks of size 15 x 10 x 10 cm with cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size), painting two coats of approved wood preservative to sides of chowkhats and making good the damages to walls and floors as required complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge. (DSR 14.2) Window chowkhats (DSR 14.2.2) 311 Fixing chowkhat in existing opening in brick/ RCC wall with dash fasteners/Chemical fasteners of appropriate size (3 nos on each vertical member of door chowkhat and 2 nos on each vertical member of window chowkhats), including Cost of dash fasteners/ chemical fastener. (DSR )(DSR 14.3) 312 Making the opening in brick masonry including dismantling in floor or walls by cutting masonry and making good the damages to walls, flooring and jambs complete, to match existing surface i/c disposal of mulba/ rubbish to the nearest municipal dumping ground, all complete as per direction of Engineer-in-Charge. (DSR 14.4) For door/ window/ clerestory window (DSR 14.4.1) 313 Renewing glass panes, with putty and nails wherever necessary including racking out the old putty: (DSR 14.5) Float glass panes of nominal thickness 4 mm (weight not less than 10kg/sqm) (DSR 14.5.1) 314 Renewing glass panes, with putty and nails wherever necessary including racking out the old putty: (DSR 14.5) Float glass panes of nominal thickness 5 mm (weight not less than 12.5kg/sqm) (DSR 14.5.2) 315 Renewing glass panes and refixing existing wooden fillets: (DSR 14.7) Float glass panes of nominal thickness 4 mm (weight not less than 10kg/sqm) (DSR 14.7.1) 316 Renewing glass panes and refixing existing wooden fillets: (DSR 14.7) Float glass panes of nominal thickness 5 mm (weight not less than 12.5kg/sqm) (DSR 14.7.2) 317 Supplying and fixing new wooden fillets wherever necessary: (DSR 14.8) Hollock wood fillets (DSR 14.8.2) 318 Renewal of old putty of glass panes (length) (DSR )(DSR 14.9) 319 Refixing old glass panes with putty and nails (DSR )(DSR 14.10) 320 Fixing old glass panes with wooden fillets (excluding cost of fillets) (DSR )(DSR 14.11) 321 Providing and fixing 16 mm M.S. Fan clamps of standard shape and size in existing R.C.C. slab, including cutting chase, anchoring clamp to reinforcement bar, including cleaning, refilling, making good the chase with matching concrete, plastering and painting the exposed portion of the clamps complete. (DSR )(DSR 14.12) 322 Raking out joints in lime or cement mortar and preparing the surface for re-pointing or replastering, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge. (DSR )(DSR 14.17) 323 Renewing Wrought iron or M.S. Wheel or roller of steel door or gate and fitting and fixing the same with necessary clamps, nuts and bolts/welding and erection etc. complete. (DSR 14.22) Wheel 50 mm dia and below (DSR 14.22.1) 324 Renewing Wrought iron or M.S. Wheel or roller of steel door or gate and fitting and fixing the same with necessary clamps, nuts and bolts/welding and erection etc. complete. (DSR 14.22) Wheel above 50 mm dia (DSR 14.22.2) 325 Pumping out water caused by springs, tidal or river seepage, broken water mains or drains and the like. (DSR )(DSR 14.23) 326 Providing and fixing 25 mm thick shutters for cup board etc. : (DSR 14.26) Panelled or panelled & glazed shutters : 14.26.1 Superior class teak wood including nickel plated bright finished M.S. piano hinges with necessary screws. (DSR 14.26.1.1) 327 Providing and fixing 25 mm thick shutters for cup board etc. : (DSR 14.26) Panelled or panelled & glazed shutters : 14.26.1 Ist class teak wood including nickel plated bright finished M.S. piano hinges with necessary screws. (DSR 14.26.1.2) 328 Providing and fixing 25 mm thick shutters for cup board etc. : (DSR 14.26) Glazed shutters : 14.26.2 Superior class teak wood including nickel plated bright finished M.S. piano hinges with necessary screws. (DSR 14.26.2.1) 329 Providing and fixing 25 mm thick shutters for cup board etc. : (DSR 14.26) Glazed shutters : 14.26.2 Ist class teak wood including nickel plated bright finished M.S. piano hinges with necessary screws. (DSR 14.26.2.2) 330 Providing and fixing M.S. round or square bars with M.S. flats at required spacing in wooden frames of windows and clerestory windows. (DSR )(DSR 14.29) 331 Providing and fixing chromium plated brass butt hinges with necessary chromium plated brass screws etc. complete. (DSR 14.4) 125x70x4 mm (ordinary type) (DSR 14.40.1) 332 Providing and fixing chromium plated brass butt hinges with necessary chromium plated brass screws etc. complete. (DSR 14.4) 100x70x4 mm (ordinary type) (DSR 14.40.2) 333 Providing and fixing chromium plated brass butt hinges with necessary chromium plated brass screws etc. complete. (DSR 14.4) 75x65x4 mm (heavy type) (DSR 14.40.3) 334 Providing and fixing chromium plated brass butt hinges with necessary chromium plated brass screws etc. complete. (DSR 14.4) 75x40x2.5 mm (ordinary type) (DSR 14.40.4) 335 Providing and fixing chromium plated brass butt hinges with necessary chromium plated brass screws etc. complete. (DSR 14.4) 50x40x2.5 mm (ordinary type) (DSR 14.40.5) 336 Providing and fixing 85x42 mm chromium plated brass pull bolt lock with necessary chromium plated brass screws, nuts, bolts and washers etc. complete. (DSR )(DSR 14.41) 337 Cleaning of terrace/loft water storage tank (inside surface area) upto 2000 litre capacity at all heights with coconut brushes, duster etc., removal of silt, rubbish from the tank and cleaning the tank with fresh water disinfecting with bleaching powder @ 0.5gm per litre capacity of tank including marking the date of cleaning on the side of tank body with the help of stencil and paint and disposing of malba all complete as per direction of Engineer-in-Charge. (The old date already written on tank should be removed with paint remover or black paint and if date is not written with the stencil or old date is not removed deduction will be made @ Rs. 0.10 per litre) (if during cleaning any GI fittings or ball cock is damaged that is to be repaired by contractor at his own cost and nothing extra will be paid on this account) (DSR )(DSR 14.75A) 338 Cleaning and desilting of gully trap chamber, including removal of rubbish mixed with earth etc. and disposal of same, all as per the direction of Engineer-in-charge. (DSR )(DSR 14.76) 339 Cleaning of chocked sewer line by diesel running vehicle mounting hydraulic operated high pressure suction cum jetting sewer cleaning machine fitted with pump having 4000 litres suction capacity and 6000 litres water jetting tank capacity including skilled operator, supervising engineer etc. for cleaning and partial desilting of manholes and dechocking of sewer lines. Dechocking and flushing of sewer line from one manhole to another by high pressure jetting system of 2200 PSI for sewer line from 150mm dia upto 300mm(DSR )(DSR 14.77) 340 Cleaning of under ground sump, Over Head R.C.C. Tank ( independent staging) including disposal of slit and rubbish, all as per direction of Engineer-in-Charge. The cleaning shall consistfollowing operations:- (i)Tank shall be emptied of water by pumping & bottom shall be cleaned of silt and otherdeposits. (ii) Entire surface area of the sump shall then scrubbed thoroughly with wire brush etc. and pressure washed with water. (iii) Chlorination of RCC internal surface by liquid chlorine.(iv) The treated surface shall be dried using air jetting and all loose particles shall be removal from the surface. (v) Finally the surface shall be treated with ultraviolet radiation etc. as per direction of Engineer-in-Charge. (DSR )(DSR 14.78) 341 Disconnecting damaged overhead/terrace PVC water storage tankof any size from water supply line and removing from the terrace including shifting at ground level as per direction of Engineer-in-charge. (DSR )(DSR 14.79) 342 Providing & fixing White vitreous china water closet squatting pan (Indian type) along withS or P trap including dismantling of old WC seat and S or P trap at site complete with all operations including all necessary materials, labour and disposal of dismantled material i/c malba, all complete as per the direction of Engineer-in charge. (DSR 14.8) Orissa pattern W.C Pan of size 580x440 mm (DSR 14.80.2) 343 Cutting holes of required size in brick masonry wall for fixing of exhaust fan including providing and fixing 300 mm dia PVC pipe conforming BIS-12818 and making good the same etc. complete as per direction of Engineer-in-charge. (DSR )(DSR 14.81) 344 DismantlingW.C.Pan of all sizes including disposal of dismantled materials i/c malba all complete as per directions of Engineer-in-Charge. (DSR )(DSR 14.82) 345 Hacking of CC flooring including cleaning for surface etc. complete as per direction of the Engineer-in-Charge. (DSR )(DSR 14.83) 346 Dismantling 15 to 40 mm dia G.I. pipe including stacking of dismantled pipes (within 50 metres lead) as per direction of Engineer-in-Charge. (a) Internal Work- Exposed on wall (DSR )(DSR 14.84) 347 Taking out existing wooden door shutter, repair by cutting, painting etc. and refixing of repaired door shutters to existing door frames, including replacement of hinges with screws, etc. as required, all complete as per the direction of the Engineer-in-charge. (DSR )(DSR 14.85) 348 Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. (DSR 15.2) Nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix) (DSR 15.2.2) 349 Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge. (DSR )(DSR 15.3) 350 Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. (DSR 15.7) In cement mortar (DSR 15.7.4) 351 Removing mortar from bricks and cleaning bricks including stacking within a lead of 50 m (stacks of cleaned bricks shall be measured): (DSR 15.8) From brick work in cement mortar (DSR 15.8.3) 352 Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : (DSR 15.12) Of area 3 sq. metres and below (DSR 15.12.1) 353 Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : (DSR 15.12) Of area beyond 3 sq. metres (DSR 15.12.2) 354 Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead : (DSR 15.13) Of area 3 sq. metres and below (DSR 15.13.1) 355 Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead : (DSR 15.13) Of area beyond 3 sq. metres (DSR 15.13.2) 356 Dismantling steel work in single sections including dismembering and stacking within 50 metres lead in: (DSR 15.17) R.S. Joists (DSR 15.17.1) 357 Dismantling steel work in single sections including dismembering and stacking within 50 metres lead in: (DSR 15.17) Channels, angles, tees and flats (DSR 15.17.2) 358 Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 50 metres lead. (DSR )(DSR 15.18) 359 Dismantling steel work manually/ by mechanical means in built up sections without dismembering and stacking within 50 metres lead as per direction of Engineer-in-charge. (DSR )(DSR 15.19) 360 Demolishing dry brick pitching in floors, drains etc. including stacking of serviceable material and disposal of unserviceable material within 50 metres lead : (DSR )(DSR 15.24) 361 Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead of: (DSR 15.28) G.S. Sheet (DSR 15.28.1) 362 Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead of: (DSR 15.28) Asbestos Cement sheet (DSR 15.28.2) 363 Dismantling barbed wire or flexible wire rope in fencing including making rolls and stacking within 50 metres lead. (DSR )(DSR 15.36) 364 Dismantling G.I. pipes (external work) including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means including stacking of pipes within 50 metres lead as per direction of Engineer-in-charge : (DSR 15.44) 15 mm to 40 mm nominal bore (DSR 15.44.1) 365 Dismantling G.I. pipes (external work) including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means including stacking of pipes within 50 metres lead as per direction of Engineer-in-charge : (DSR 15.44) Above 40 mm nominal bore (DSR 15.44.2) 366 Dismantling C.I. pipes including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means breaking lead caulked joints, melting of lead and making into blocks including stacking of pipes & lead at site within 50 metre lead as per direction of Engineer-in-charge: (DSR 15.45) Up to 150 mm diameter (DSR 15.45.1) 367 Taking out C.I. cover with frame from R.C.C. top slab of manholes of various sizes including demolishing of R.C.C. work manually/ by mechanical means and stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead as per direction of Engineer-in-charge. (DSR )(DSR 15.48) 368 Taking out C.I. cover with frame from R.C.C. top slab of inspection chambers of various sizes including demolishing of R.C.C. work manually/ by mechanical means and stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead as per direction of Engineer-in-charge. (DSR )(DSR 15.49) 369 Dismantling of flushing cistern of all types (C.I./PVC/Vitrious China) including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead. (DSR )(DSR 15.52) 370 Dismantling of C.I. sluice valve including stacking of useful materials within a lead of 50 metres (DSR 15.53) Up to 150 mm diameter (DSR 15.53.1) 371 Dismantling of spindle fire hydrant including stacking of useful materials within 50 metres lead. (DSR )(DSR 15.54) 372 Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. (DSR )(DSR 15.56) 373 Dismantling aluminium/ Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable material and stacking of serviceable material with in 50 meters lead as directed by Engineer-in-charge. (DSR )(DSR 15.57) 374 Demolishing R.C.C. work by mechanical means and stockpiling at designated locations and disposal of dismantled materials up to a lead of 1 kilometre, stacking serviceable and unserviceable material separately including cutting reinforcement bars. (DSR )(DSR 15.58) 375 Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. (DSR )(DSR 15.60) 376 Brick edging in full brick width and half brick depth including excavation, refilling and disposal of surplus earth lead upto 50 metres. (DSR 16.7) With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 (DSR 16.7.1) 377 Brick edging laid lengthwise with half brick depth including excavation, refilling and disposal of surplus earth lead upto 50 metres : (DSR 16.8) With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 (DSR 16.8.1) 378 Supplying at site : (DSR 16.15) R.C.C. Standards post/ struts/rails/ pales of mix 1:1.5:3 (1 cement : 1.5 coarsesand : 3 graded stone aggregate 12.5 mm nominal size) with wooden plugs or 6mm bar nibs wherever required as per direction of Engineer-in- charge (cost of earth works in excavation, concrete works in foundation to be paid separately). (DSR 16.15.1) 379 Supplying at site : (DSR 16.15) Welded steel wire fabric of required width having rectangular mesh painted with two or more coats of enamel paint of approved shade over a coat of primer (Priming & Painting to be paid for separately). (DSR 16.15.2) 380 Fencing with R.C.C. post placed at required distance, embedded in cement concrete blocks, every 15th post, last but one end post and corner post shall be strutted on both sides and end post one side only, provided with horizontal lines and two diagonals of barbed wire weighing 9.38 kg per 100 metres (minimum), between the two posts fitted and fixed with G.I. staples on wooden plugs or G.I. binding wire tied to 6 mm bar nibs fixed while casting the post (cost of R.C.C. posts, struts, earth work and concrete to be paid for separately) :- Payment to be made per metre cost of total length of barbed wire used. (DSR 16.17) With G.I. barbed wire (DSR 16.17.1) 381 Fencing with angle iron post placed at required distance embedded in cement concrete blocks, every 15th post, last but one end post and corner post shall be strutted on both sides and end post on one side only and provided with horizontal lines and two diagonals interwoven with horizontal wires, of barbed wire weighing 9.38 kg per 100 m (minimum), between the two posts fitted and fixed with G.I. staples, turn buckles etc. complete. (Cost of posts, struts, earth work and concrete work to be paid for separately). Payment to be made per metre cost of total length of barbed wire used. (DSR 16.18) With G.I. barbed wire (DSR 16.18.1) 382 Supplying at site Angle iron post & strut of required size including bottom to be split and bent at right angle in opposite direction for 10 cm length and drilling holes upto 10 mm dia. etc. complete. (DSR )(DSR 16.19) 383 Providing and applying tack coat using bitumen emulsion conforming to IS:8887, using emulsion pressure distributer including preparing the surface & cleaning with mechanical broom. (DSR 16.31) With medium setting bitumen emulsion 16.31.2 On bituminous surface @ 0.25kg/sqm (DSR 16.31.2.2) 384 2.5 cm premix carpet surfacing with 2.25 cum and 1.12 cum of stone chippings of 13.2 mm and 11.2 mm size respectively per 100 sqm and 52 kg and 56 kg of hot bitumen per cum of stone chippings of 13.2 mm and 11.2 mm size respectively, including a tack coat with hot straight run bitumen, including consolidation with road roller of 6 to 9 tonne capacity etc. complete (tack coat to be paid for separately). (DSR 16.33) With paving Asphalt grade VG - 10 heated and then mixed with solvent at the rate of 70 grams per kg of asphalt (DSR 16.33.1) 385 Providing and laying seal coat of premixed fine aggregate ( passing 2.36 mm and retained on 180 micron sieve) with bitumen using 128 kg of bitumen of grade VG - 10 bitumen per cum of fine aggregate and 0.60 cum of fine aggregate per 100 sqm of road surface, including rolling and finishing with road roller all complete. (DSR )(DSR 16.40) 386 Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 40 mm nominal size) in pavements, laid to required slope and camber in panels as required including consolidation finishing and tamping complete. (DSR )(DSR 16.42) 387 Extra for providing and mixing hardening compound of approved quality as per manufacturers specification in cement concrete. (DSR )(DSR 16.44) 388 Providing and fixing pre-moulded joint filler in expansion joints of RCC roads / CC pavements after making the joints dust free with high pressure air jet cleaners, all complete as per direction of the Engineer-in-Charge. (Pre-moulded joint fillers shall be made of bitumen hot sealing compound impregnated fibre board having impregnation more than 35%, conforming to IS:1838 for fibre board and IS: 1834 for hot sealing bitumen compound grade A.) (DSR )(DSR 16.45) 389 Providing and fixing concertina coil fencing with punched tape concertina coil 600 mm dia 10 metre openable length ( total length 90 m), having 50 nos rounds per 6 metre length, upto 3 m height of wall with existing angle iron Y shaped placed 2.4m or 3.00 m apart and with 9 horizontal R.B.T. reinforced barbed wire, stud tied with G.I. staples and G.I. clips to retain horizontal, including necessary bolts or G.I. barbed wire tied to angle iron, all complete as per direction of Engineer-in-charge, with reinforced barbed tape(R.B.T.) / Spring core (2.5mm thick) wire of high tensile strength of 165 kg/ sq.mm with tape (0.52 mm thick) and weight 43.478 gm/ metre (cost of M.S. angle, C.C. blocks shall be paid separately) (DSR )(DSR 16.53) 390 Providing and laying 75 mm thick compacted bed of dry brick aggregate of 40 mm thick nominal size including spreading, well ramming, consolidating and grouting with jamuna sand, including finishing smooth etc. complete as per direction of Engineer-in-charge. (DSR )(DSR 16.64) 391 Providing and fixing at or near ground level factory made RCC pavement slab of M-30 grade of size 450x450x50 mm, including reinforcement with 6 mm dia M.S. bars 4 nos on each side, including setting in position in footpath to the required level and line over a bed of 20 mm average thick cement mortar 1:5 (1 cement : 5 coarse sand), having joint thickness not more than 5mm except on curve, including filling of joints with same cement mortar and making grooves etc. complete as per direction of Engineer-in-charge. (DSR )(DSR 16.67) 392 Providing and laying 60mm thick faciory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge. (DSR )(DSR 16.68) 393 Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured to calculate volume for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge). (DSR )(DSR 16.69) 394 Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-in-charge. (DSR 16.7) Made of G.I. wire of dia 4 mm (DSR 16.70.1) 395 Providing and laying C.C. pavement of mix M-25 with ready mixed concrete from batching plant. The ready mixed concrete shall be laid and finished with screed board vibrator , vacuum dewatering process and finally finished by floating, brooming with wire brush etc. complete as per specifications and directions of Engineer-in-charge. (The panel shuttering work shall be paid for separately).(Note:- Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/ recoverable separately). (DSR )(DSR 16.75) 396 Deduct for using of M-20 grade concrete instead of M-25 grade concrete in C.C. pavement. (DSR )(DSR 16.76) 397 Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge. (DSR 16.78) With material conforming to Grade-II (size range 53 mm to 0.075 mm ) having CBR Value-25 (DSR 16.78.2) 398 Taking out existing CC interlocking paver blocks from footpath/ central verge, including removal of rubbish etc., disposal of unserviceable material to the dumping ground, for which payment shall be made separately and stacking of serviceable material within 50 metre lead as per direction of Engineer-in-Charge. (DSR )(DSR 16.83) 399 Laying old cement cocrete interlocking paver blocks of any design/ shape laid in required line, level, curvature, colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge. (Old CC paver blocks shall be supplied by the department free of cost). (DSR )(DSR 16.84) 400 Providing and laying matt finished vitrified tile of size 300x300x9.8mm having with water absorption less than 0.5% and conforming to IS: 15622 of approved make in all colours and shades in for outdoor floors such as footpath, court yard, multi modals location etc., laid on 20mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as per direction of Engineer-in-Charge. (DSR )(DSR 16.89) 401 Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed ofsand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. (DSR 16.91) 60mm thick cement concrete paver block of M-35 grade with approved colour, design & pattern. (DSR 16.91.1) 402 Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed ofsand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. (DSR 16.91) 80 mm thick C.C. paver block of M-35 grade with approved colour design and pattern. (DSR 16.91.2) 403 Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: (DSR 17.1) White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests (DSR 17.1.1) 404 Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : (DSR 17.2) W.C. pan with ISI marked white solid plastic seat and lid (DSR 17.2.1) 405 Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : (DSR 17.3) W.C. pan with ISI marked white solid plastic seat and lid (DSR 17.3.1) 406 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: (DSR 17.7) White Vitreous China Wash basin size 550x400 mm with a pair of 15 mm C.P. brass pillar taps (DSR 17.7.3) 407 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: (DSR 17.7) White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tap (DSR 17.7.4) 408 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: (DSR 17.7) White Vitreous China Surgeon type wash basin of size 660x460 mm with single 15 mm C.P. brass pillar taps with elbow operated levers ISI Marked (DSR 17.7.9) 409 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: (DSR 17.7) Stainless Steel AISI-304(18/8) Wash basin 530x345 mm with single 15 mm C.P. brass pillar tap (DSR 17.7.11) 410 Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:-(a)White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer (DSR )(DSR 17.7A) 411 Providing and fixing kitchen sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P. brass waste complete, including painting the fittings and brackets, cutting and making good the walls wherever required: (DSR 17.9) White glazed fire clay kitchen sink of size 600x450x 250 mm (DSR 17.9.1) 412 Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : (DSR 17.1) Kitchen sink with drain board510x1040 mm bowl depth 200 mm (DSR 17.10.1.3) 413 Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : (DSR 17.1) Kitchen sink without drain board 17.10.2 610x510 mm bowl depth 200 mm (DSR 17.10.2.1) 414 Providing and fixing white vitreous china pedestal type (European type/ wash down type) water closet pan. (DSR )(DSR 17.15) 415 Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge. (DSR )(DSR 17.16A) 416 Providing and fixing P.V.C. low level flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete. (DSR 17.18) 10 litre capacity - White (DSR 17.18.1) 417 Providing and fixing solid plastic seat with lid for pedestal type W.C. pan complete : (DSR 17.2) White solid plastic seat with lid (DSR 17.20.1) 418 Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. (DSR )(DSR 17.22A) 419 Providing and fixing CP Brass Single lever telephonic wall mixer of quality & make as approved by Engineer in charge.(a) 15 mm nominal dia (DSR )(DSR 17.22B) 420 Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm or 340x410x265 mm sizes respectively. (DSR )(DSR 17.23) 421 Providing and fixing white vitreous china squatting plate urinal with integral rim longitudinal flush pipe. (DSR )(DSR 17.24) 422 Providing and fixing white vitreous china wash basin including making all connections but excluding the cost of fittings : (DSR 17.25) Flat back wash basin of size 630x450 mm (DSR 17.25.1) 423 Providing and fixing white vitreous china wash basin including making all connections but excluding the cost of fittings : (DSR 17.25) Flat back wash basin of size 550x400 mm (DSR 17.25.2) 424 Providing and fixing white vitreous china wash basin including making all connections but excluding the cost of fittings : (DSR 17.25) Flat back wash basin of size 450x300 mm (DSR 17.25.5) 425 Providing and fixing kitchen sink including making all connections excluding cost of fittings. (DSR 17.26) White glazed fire clay sink of size 600x450x250 mm (DSR 17.26.1) 426 Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. (DSR 17.28) Semi rigid pipe 17.28.1 32 mm dia (DSR 17.28.1.1) 427 Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. (DSR 17.28) Flexible pipe 17.28.2 32 mm dia (DSR 17.28.2.1) 428 Providing and fixing 100 mm sand cast Iron grating for gully trap. (DSR )(DSR 17.29) 429 Providing and fixing in position 25 mm diameter mosquito proof coupling of approved municipal design. (DSR )(DSR 17.30) 430 Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. (DSR )(DSR 17.31) 431 Providing and fixing 600x120x5 mm glass shelf with edges round off, supported on anodised aluminium angle frame with C.P. brass brackets and guard rail complete fixed with 40 mm long screws, rawl plugs etc., complete. (DSR )(DSR 17.33) 432 Providing and fixing toilet paper holder : (DSR 17.34) C.P. brass (DSR 17.34.1) 433 Providing and fixing toilet paper holder : (DSR 17.34) Vitreous china (DSR 17.34.2) 434 Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour. (DSR 17.69) Waste coupling 31 mm dia of 79 mm length and 62mm breadth weighing not less than 45 gms (DSR 17.69.1) 435 Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour. (DSR 17.69) Waste coupling 38 mm dia of 83 mm length and 77mm breadth, weighing not less than 60 gms (DSR 17.69.2) 436 Providing and fixing PTMT Bottle Trap for Wash basin and sink. (DSR 17.7) Bottle trap 31mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 gms (DSR 17.70.1) 437 Providing and fixing PTMT Bottle Trap for Wash basin and sink. (DSR 17.7) Bottle trap 38 mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 263 gms (DSR 17.70.2) 438 Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. (DSR )(DSR 17.71) 439 Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms. (DSR )(DSR 17.72) 440 Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. (DSR 17.73) 450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm, weighing not less than 170 gms (DSR 17.73.1) 441 Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. (DSR 17.73) 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. (DSR 17.73.2) 442 Providing and fixing PTMT shelf 440 mm long, 124 mm width and 36 mm height of approved quality and colour, weighing not less than 300 gms. (DSR )(DSR 17.74) 443 Providing and fixing PTMT 15 mm Urinal spreader size 95x69x100 mm with 1/2 BSP thread and shapes, weighing not less than 60 gms. (DSR )(DSR 17.75) 444 Providing and fixing PTMT urinal cock of approved quality and colour. (DSR 17.76) 15 mm nominal bore, 80 mm long, 42 mm high and 30mm wide with BSP female threads weighing not less than 48 gms (DSR 17.76.1) 445 Providing and fixing M.S. holder bat clamp of approved design to sand cast iron/ cast iron (spun) pipes comprising of M.S. flat brackets made of 50x5 mm flat of specified shape, projecting 75 mm outside the wall surface and fixed on wall with 4nos, 6mm dia expansion hold fasteners, including drilling necessary holes in brick wall/ CC/ RCC surface and the cost of bolts etc. The pipes shall be fixed to the already fixed brackets with the help of 30 mm x1.6 mm galvanised M.S. flats of specified shape and of total length 420 mm and shall be fixed with M.S. nuts, bolts, & washers of size 25x6 mm, one bolts on each side of the pipe. (DSR 17.77) Total bracket length 580 mm of approved shape and design (for single 100 mm dia pipe) (DSR 17.77.1) 446 Providing and fixing white vitreous china extended wall mounting water closet of size 780x370x690 mm of approved shape including providing & fixing white vitreous china cistern with dual flush fitting, of flushing capacity 3 litre/ 6 litre (adjustable to 4 litre/ 8 litres), including seat cover, and cistern fittings, nuts, bolts and gasket etc complete. (DSR )(DSR 17.78) 447 Providing & fixing white vitreous china water less urinal of size 600 x 330 x 315 mm having antibacterial /germs free ceramic surface, fixed with cartridge having debris catcher and hygiene seal. (DSR )(DSR 17.79) 448 Providing and fixing white vitreous china battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre & post flushing with water (250 ml & 500 ml consumption), having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of Engineer-in-charge. (DSR )(DSR 17.80) 449 Providing and fixing floor mounted, white vitreous china single piece, double traps syphonic water closet of approved brand/make, shape, size and pattern including integrated white vitreous china cistern of capacity 10 litres with dual flushing system, including all fittings and fixtures with seat cover, cistern fittings, nuts, bolts and gasket etc including making connection with the existing P/S trap, complete in all respect as per directions of Engineer-in-Charge. (DSR )(DSR 17.81) 450 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.(Concealed work, including cutting chases and making good the walls etc.) (DSR 18.8) 20 mm nominal dia Pipes (DSR 18.8.2) 451 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.(Concealed work, including cutting chases and making good the walls etc.) (DSR 18.8) 25 mm nominal dia Pipes (DSR 18.8.3) 452 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) (DSR 18.9) 15 mm nominal dia Pipes (DSR 18.9.1) 453 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) (DSR 18.9) 20 mm nominal dia Pipes (DSR 18.9.2) 454 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) (DSR 18.9) 25 mm nominal dia Pipes (DSR 18.9.3) 455 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) (DSR 18.9) 32 mm nominal dia Pipes (DSR 18.9.4) 456 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) (DSR 18.9) 40 mm nominal dia Pipes (DSR 18.9.5) 457 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) (DSR 18.9) 50 mm nominal dia Pipes (DSR 18.9.6) 458 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) (DSR 18.9) 80 mm nominal dia Pipes (DSR 18.9.8) 459 Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc.External work (DSR 18.12) 80 mm dia nominal bore (DSR 18.12.8) 460 Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete : (DSR 18.13) 25 to 40 mm nominal bore (DSR 18.13.1) 461 Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete : (DSR 18.13) 50 to 80 mm nominal bore (DSR 18.13.2) 462 Fixing water meter and stop cock in G.I. pipe line including cutting and threading the pipe and making long screws etc. complete (cost of water meter and stop cock to be paid separately). (DSR )(DSR 18.14) 463 Providing and fixing brass bib cock of approved quality : (DSR 18.15) 15 mm nominal bore (DSR 18.15.1) 464 Providing and fixing brass bib cock of approved quality : (DSR 18.15) 20 mm nominal bore (DSR 18.15.2) 465 Providing and fixing brass stop cock of approved quality : (DSR 18.16) 15 mm nominal bore (DSR 18.16.1) 466 Providing and fixing brass stop cock of approved quality : (DSR 18.16) 20 mm nominal bore (DSR 18.16.2) 467 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : (DSR 18.17) 25 mm nominal bore (DSR 18.17.1) 468 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : (DSR 18.17) 20 mm nominal bore (DSR 18.17.1A) 469 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : (DSR 18.17) 32 mm nominal bore. (DSR 18.17.2) 470 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : (DSR 18.17) 40 mm nominal bore (DSR 18.17.3) 471 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : (DSR 18.17) 80 mm nominal bore (DSR 18.17.6) 472 Providing and fixing gun metal non- return valve of approved quality (screwed end) : (DSR 18.19) 25 mm nominal bore 18.19.1 Horizontal (DSR 18.19.1.1) 473 Providing and fixing gun metal non- return valve of approved quality (screwed end) : (DSR 18.19) 25 mm nominal bore 18.19.1 Vertical (DSR 18.19.1.2) 474 Providing and fixing gun metal non- return valve of approved quality (screwed end) : (DSR 18.19) 32 mm nominal bore 18.19.2 Horizontal (DSR 18.19.2.1) 475 Providing and fixing gun metal non- return valve of approved quality (screwed end) : (DSR 18.19) 32 mm nominal bore 18.19.2 Vertical (DSR 18.19.2.2) 476 Providing and fixing gun metal non- return valve of approved quality (screwed end) : (DSR 18.19) 40 mm nominal bore 18.19.3 Horizontal (DSR 18.19.3.1) 477 Providing and fixing gun metal non- return valve of approved quality (screwed end) : (DSR 18.19) 40 mm nominal bore 18.19.3 Vertical (DSR 18.19.3.2) 478 Providing and fixing gun metal non- return valve of approved quality (screwed end) : (DSR 18.19) 80 mm nominal bore 18.19.6 Vertical (DSR 18.19.6.2) 479 Providing and fixing uplasticised PVC connection pipe with brass unions : (DSR 18.21) 30 cm length 18.21.1 15 mm nominal bore (DSR 18.21.1.1) 480 Providing and fixing uplasticised PVC connection pipe with brass unions : (DSR 18.21) 30 cm length 18.21.1 20 mm nominal bore (DSR 18.21.1.2) 481 Providing and fixing uplasticised PVC connection pipe with brass unions : (DSR 18.21) 45 cm length 18.21.2 15 mm nominal bore (DSR 18.21.2.1) 482 Providing and fixing uplasticised PVC connection pipe with brass unions : (DSR 18.21) 45 cm length 18.21.2 20 mm nominal bore (DSR 18.21.2.2) 483 Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : (DSR 18.22) 100 mm diameter (DSR 18.22.1) 484 Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : (DSR 18.22) 150 mm diameter (DSR 18.22.2) 485 Providing and laying S&S centrifugally cast (spun) iron pipes (Class LA) conforming to IS - 1536 : (DSR 18.27) 100 mm dia pipe (DSR 18.27.1) 486 Providing lead caulked joints to spun iron or C.I. pipes and specials, including testing of joints but excluding the cost of pig lead : (DSR 18.28) 100 mm diameter pipe (DSR 18.28.1) 487 Providing flanged joints to double flanged C.I./ D.I. pipes and specials, including testing of joints : (DSR 18.3) 80 mm diameter pipe (DSR 18.30.1) 488 Providing flanged joints to double flanged C.I./ D.I. pipes and specials, including testing of joints : (DSR 18.3) 100 mm diameter pipe (DSR 18.30.2) 489 Providing and fixing C.I. sluice valves (with cap) complete with bolts, nuts, rubber insertions etc. (the tail pieces if required will be paid separately) : (DSR 18.31) 100 mm diameter 18.31.1 Class I (DSR 18.31.1.1) 490 Providing and fixing C.I. sluice valves (with cap) complete with bolts, nuts, rubber insertions etc. (the tail pieces if required will be paid separately) : (DSR 18.31) 100 mm diameter 18.31.1 Class II (DSR 18.31.1.2) 491 Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. (DSR )(DSR 18.48) 492 Providing and fixing PTMT Ball cock of approved quality, colour and make complete with Epoxy coated aluminium rod with L.P./ H.P.H.D. plastic ball. (DSR 18.62) 20 mm nominal bore, 120 mm long, weighing not less than 198 gms (DSR 18.62.2) 493 Providing and fixing PTMT angle stop cock 15 mm nominal bore, weighing not less than 85 gms (DSR )(DSR 18.63) 494 Providing and fixing PTMT swivelling shower, 15 mm nominal bore, weighing not less than 40 gms (DSR )(DSR 18.64) 495 Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms. (DSR )(DSR 18.65) 496 Providing & fixing chrome plated brass battery based infrared sensor operated pillar cock, having foam flow technology. (DSR 18.84) 15 mm nominal bore (DSR 18.84.1) 497 Dismantling of old S.W. pipes including breaking of joints and bed concrete stacking of useful materials near the site within 50 m lead and disposal of unserviceable materials into municipal dumps : (DSR 19.5) 100 mm diameter (DSR 19.5.1) 498 Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : (DSR 19.6) 150 mm dia. R.C.C. pipe (DSR 19.6.2) 499 Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : (DSR 19.6) 300 mm dia. R.C.C. pipe (DSR 19.6.4) 500 Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design. (DSR 19.32) With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 (DSR 19.32.1) 501 Constructing soak pit 1.20x1.20x1.20 m filled with brickbats including S.W. drain pipe 100 mm diameter and 1.20 m long complete as per standard design. (DSR )(DSR 19.33) 502 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fastenersto be paid for separately) : (DSR 21.1) For fixed portion 21.1.1 Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) (DSR 21.1.1.1) 503 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fastenersto be paid for separately) : (DSR 21.1) For fixed portion 21.1.1 Powder coated aluminium (minimum thickness of powder coating 50 micron) (DSR 21.1.1.2) 504 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fastenersto be paid for separately) : (DSR 21.1) For fixed portion 21.1.1 Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micron) (DSR 21.1.1.3) 505 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fastenersto be paid for separately) : (DSR 21.1) For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) 21.1.2 Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) (DSR 21.1.2.1) 506 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fastenersto be paid for separately) : (DSR 21.1) For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) 21.1.2 Powder coated aluminium (minimum thickness of powder coating 50 micron) (DSR 21.1.2.2) 507 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fastenersto be paid for separately) : (DSR 21.1) For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) 21.1.2 Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micron) (DSR 21.1.2.3) 508 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): (DSR 21.3) With float glass panes of 4.0 mm thickness (weight not less than 10kg/sqm) (DSR 21.3.1) 509 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): (DSR 21.3) With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm) (DSR 21.3.2) 510 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): (DSR 21.3) With float glass panes of 8 mm thickness (weight not less than 20 kg/sqm) (DSR 21.3.3) 511 Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge. (DSR 21.4) With stainless steel cover plate minimum 1.25 mm thickness (DSR 21.4.1) 512 Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge. (DSR 21.4) With brass cover plate minimum 1.25 mm thickness (DSR 21.4.2) 513 Providing and fixing powder coated aluminium work (minimum thickness of powder coating 50 micron) consisting of tee/ angle sections, of approved make conforming to IS : 733 in frames of false ceiling including aluminium angle cleats with necessary C.P. brass/ stainless steel sunk screws, aluminium perimeter angles fixed to wall with stainless steel rawl plugs @ 450 mm centre to centre and fixing the frame work to G.I. level adjusting hangers 6 mm dia. with necessary cadmium plated machine screws all complete as per approved architectural drawings and direction of the Engineer-in-charge (level adjusting hangers, ceiling cleats and expansion hold fasteners to be paid for separately). (DSR )(DSR 21.5) 514 Providing and fixing 6 mm dia. G.I. level adjusting hangers (upto 1200mm length), fixed to roof slabs by means of ceiling cleats made out of G.I. flat 40x3mm size 60 mm long and stainless steel expandable dash fastener of 12.5 mm dia and 50 mm long, complete as per direction of Engineer-in-charge. (DSR )(DSR 21.6) 515 Filling the gap in between aluminium frame & adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete. (DSR 21.8) Upto 5mm depth and 5 mm width (DSR 21.8.1) 516 Extra for applying additional anodic coating AC 25 instead of AC 15 to aluminium extruded sections. (DSR 21.9) For fixed portion (DSR 21.9.1) 517 Extra for applying additional anodic coating AC 25 instead of AC 15 to aluminium extruded sections. (DSR 21.9) For shutters of doors, windows & ventilators (DSR 21.9.2) 518 Providing and fixing anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868. Minimum anodic coating of grade AC 15) sub frame work for windows and ventilators with extruded built up standard tubular sections of approved make conforming to IS: 733 and IS: 1285, fixed with dash fastener of required dia and size (Dash fastener to be paid for separately). (DSR )(DSR 21.14) 519 Providing and fixing anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer-in-charge. (Only weight of grill to be measured for payment). (DSR )(DSR 21.17) 520 Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double acting hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge (Door handle, lock and stopper etc.to be paid separately). (DSR )(DSR 21.18) 521 Filling the gap in between aluminium/ stone/ wood frame and adjacent RCC/Brick/ Stone/ wood/ Ceramic/ Gypsum work by providing weather/structural non sag elastomeric PU sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete, complying to ASTM C920, DIN 18540-F & ISO 11601 (DSR 21.19) Upto 5 mm depth and 5 mm width (DSR 21.19.1) 522 Filling the gap in between aluminium/ stone/ wood frame and adjacent RCC/Brick/ Stone/ wood/ Ceramic/ Gypsum work by providing weather/structural non sag elastomeric PU sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete, complying to ASTM C920, DIN 18540-F & ISO 11602 (DSR 21.19) Upto 10 mm depth and 10 mm width (DSR 21.19.2) 523 Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying :(a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours.(b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours.(The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.) (DSR )(DSR 22.5) 524 Providing and mixing integral crystalline admixture for water proofing treatment to RCC structures like basement raft, retaining walls, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc. at the time of transporting of concrete into the drum of the ready-mix truck ,using integral crystalline admixture @0.80% (minimum) to the weight of cement content per cubic meter of concrete) or higher as recommended by the manufacturers specification in reinforced cement concrete at site of work. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e. by reducing permeability of concrete by more than 90%, compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure. The crystalline admixture shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the Engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage. (DSR )(DSR 22.22) 525 Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge, upto 90 metre depth below ground level. (DSR 23.1) All types of soil 23.1.1 300 mm dia (DSR 23.1.1.1) 526 Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, beyond 90 metre & upto 150 metre depth below ground level. (DSR 23.2) All types of soil 23.2.1 350 mm dia (DSR 23.2.1.2) 527 Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge. (DSR 23.3) 150 mm nominal size dia (DSR 23.3.2) 528 Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. (DSR 23.4) 150 mm nominal size dia (DSR 23.4.2) 529 Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. (DSR )(DSR 23.5) 530 Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. (DSR )(DSR 23.6) 531 Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge. (DSR )(DSR 23.7) 532 Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge. (DSR )(DSR 23.8) 533 Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by V notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge. (DSR )(DSR 23.12) 534 Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: (DSR 23.13) 150 mm dia (DSR 23.13.2) 535 Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete. (DSR 23.14) 150 mm clamp (DSR 23.14.2) 536 Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I). (DSR 23.15) 150 mm dia (DSR 23.15.2) 537 Providing and supplying aluminium extruded tubular and other aluminium sections as per the architectural drawings and approved shop drawings , the aluminium quality as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in-Charge. ( The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account). The weight of aluminium extruded section shall be taken for purpose of payment. (DSR )(DSR 25.1) 538 Providing and fixing factory madeKitchen Cabinet Shutter/Partition 20 mm nominal thickness of approved shade, quality and make, made from rigid foam sheets (Single extruded) having density 600 Kg/cum and laminated on both side by laminate Sheet/PVC foil lamination. The exposed edges shall be sealed with PVC edge beading of same shade and colour. The shutter shall be fire retardenthaving necessary screw holding capacity.Shutter shall be fixed to frame usingapproved hinges with necessary stainless steel screws, all complete as per direction of Engineer-in-charge. (DSR )(DSR 26.10) 539 Providing and fixing concealed hinge of approved quality for 19-20mm thick door with stainless steel screws complete : (DSR )(DSR 26.11) 540 Wiring for light point/ fan point/ exhaust fan point/ call bell point with1.5 sq mm frls pvc insulated copper conductor single core cable in surface /recessed medium class pvc conduit , with modular switch ,modular plate, suitable GI box and earething the pint with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. (DSR E&M 1.10)Group A (DSR E&M 1.10.1) 541 Wiring for light/power plug with 2x4 sq. mm FRLS PVC insulatted copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. (DSR E&M 1.12) 542 Wiring for circuit/submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. (DSR E&M 1.14) 2x2.5sq. Mm + 1x2.5 sq. mm eartrh wire (DSR E&M 1.14.2) 543 Wiring for circuit/submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. (DSR E&M 1.14) 2x4sq. Mm + 1x4 sq. mm eartrh wire (DSR E&M 1.14.3) 544 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. (DSR E&M 1.21) 25mm (DSR E&M 1.21.2) 545 Supplying and fixing 6way, Double door, single pole and neutral, sheet steel, MCB distribution board, 240V, on Surface/recess,complete with tinned copper bus bar, heutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But with MCB/RCCB/Isolator) (DSR E&M 2022 2.3.1) 546 Supplying and fixing 5 amps to 32 amps rating,Single pole, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (DSR E&M 2022 2.10.1) 547 Supplying and fixing 63 amps, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.(DSR E&M 2022 2.12.2) 548 Supplying and fixing 63 A, four pole, 415V, isolator in the existing MCB DB Complete with connections, testing and commissioning etc. as required. (DSR E&M 2022 2.13.2) 549 Earthing with G.I earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. (DSR E&M 2022 5.2) 550 Smoke Detector with built in LED, mounting base complete with all connection etc. (DSR E&M 2022 4102) 551 Manual call boxes of MS Type in surface/recess with stainless steel chain & hammer assembly complete with glass and push button etc. (DSR E&M 2022 4103) 552 Manual call boxes of ABS Type in surface/recess with stainless steel chain & hammer assembly complete with glass and push button etc. (DSR E&M 2022 4104) 553 Response indicator on surface/recessed MS Box having two LEDs metallic covers complete with all connections etc.(DSR E&M 2022 4105) 554 Fire alarm sounders (electronic) with facility to make announcement, mounted in M.S. Box (16 SWG) with hinged cover plate & suitable for operation with amplifier i/c line matching transformer etc. (DSR E&M 2022 4106) 555 Fire alarm sounders (electronic) with facility to make announcement, mounted in A,B.S. Box with hinged cover plate & suitable for operation with amplifier l/c line matching ttransformer etc. (DSR E&M 2022 4107) 556 Talk back slave station in surface/recess suitable for operation on simplex mode complete with P.T.T. Knob & speaker/microphone enclosed in a M.S (16 SWG)/ABS.Box, break glass in front etc. (DSR E&M 2022 4108) 557 6 Zone fire alarm control panel as per IS: 2189 with backlit LCD (DSR E&M 2022 4110) 558 Cost of25 mm outer dia PVC/ABS Pipe with end caps including making air sampling operning of appropriate dia on appropriate interval. (DSR E&M 2022 4143) 559 Cost of fire survival armoured cable, fibre, fibre glass tape wrapped, ZH inner, outer sheath 2x1.5 sq. mm cable(DSR E&M 2022 4144) 560 Cost of fire alarm armoured FRLS cable 2 x 1.5 sqmm (DSR E&M 2022 4145) 561 Supply, Installation, Testing and Commissioning of 1200 mm sweep,BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required (DSR E&M 2022 19.1) 562 Concrete with 4cm gauge I class brick ballast, coarse sand (F.M. 1.8 to 2.5) and cement in proportion of 12:6:1 in foundations and under floors including supply of all materials, labour and tools and plants etc. required for proper completion. (CSI No.5.01 ) 563 Concrete work with 40 mm gauge brick ballast obtained from breaking brick bats (brick bats supplied by the department free of cost) in proportion of 12:6:1 as in CSI no. 5.01 including cost of all labour, materials, T&P etc required for proper completion of work. (CSI No. 5.20) 564 Brick work in foundation & plinth with old dismantled bricks (supplied by department free of cost) and coarse sand of F.M. 1.8 to 2.5 mortar in 1:6 including supply of all other materials, labour, removing mortar & cleaning of old & used bricks,T&P etc complete. (CSI No. 6.18) 565 Brick work in Super structure with old dismantled bricks (supplied by department free of cost) and coarse sand of F.M. 1.8 to 2.5 mortar in 1:6 including supply of all other materials, labour, removing mortar & cleaning of old & used bricks,T&P etc complete. (CSI No. 6.19) 566 S/F welded wire mesh size 75x25mm and rectangular made out of 10 SWG over M.S. angle frame with M.S. flat welded as required including cost of drilling holes, washer welding etc as required including cost of all material, labour and T&P etc. required for proper completion of work . exept cost of M.S angle and flat. (CSI No. 9.22) 567 Providing and laying SWR, PVC ( Finolex or equivalent ) pipe including cost of excavation, C.C etc including its jointing and connection, all materials, labour and T&P etc. required for proper completion of the work. (CSI No. 27.29 c) 110 mm dia 568 Supply and Fixing of 3 blade wall fan of Havells platina 400 mm or equivalent including all material, T&P etc required for proper completion of work as approved by engineer in charge. (CSI No. 28.37) 569 Supply and Fixing of 5 blade Exhaust fan ventile air dx 225 mm of Havells or equivalent make including all material, T&P etc required for proper completion of work as approved by engineer in charge.(CSI No. 28.38) 570 Supply & fixing steel tubular pole 7 Metre long designated 410 SP-2 in 1:3:6 cement concrete foundation including excavation back filling etc. complete in all respect. 2018 PWD 603 571 Supply & fixing of 7 mtr GI Octagonal Pole of approved make (top dia 70mm, Bottom dia 130mm and base plate 12mm thik) having 3mm thikness with single arm bracket (1 Mtr length) on RCC foundationincluding the cost of foundation, foundation bolts, excavation & back filling and Required T&P completee in all respect. 2018 PWD 641 572 Supply & fixing of 7 mtr GI Octagonal Pole of approved make (top dia 70mm, Bottom dia 130 mm and base plate 12mm thik) having 3mm thikness with Double arm bracket (1 Mtr length) on RCC foundationincluding the cost of foundation, foundation bolts, excavation & back filling and Required T&P completee in all respect. 2018 PWD 642 573 Supply and fixing of fire extinguisher, ABC Type 4.00 kg. capacity (ISI Marked IS : 15683 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. 2018 PWD 1131 574 Supply and fixing of fire extinguisher, ABC Type 6.00 kg. capacity (ISI Marked IS : 15683 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. 2018 PWD 1131(A) 575 Supply and fixing of C02 type fire extinguisher 4.5 kg. capacity (ISI Marked IS : 2878 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. 2018 PWD 1132 576 Same as in item no. 1132 but of 6..5 kg. capacity 2018 PWD 1132 (A) 577 Supply and fixing of fire bucket, round bottom made of G.I. sheet 9-11 litres capacity duly painted as per fire brigade design, supported on hanging bracket chained and locked, initially filled with fine river sand, water as per directions of Engineer-in-Charge 2018 PWD 1133 578 Supply and fixing of power plug with 15A/250 voltflushtype switch and 5 pin 15A/250V flush type universal socket in suitable M.S. box of 175mm x 100mm x 50mmsize with phenolic laminated bakelite sheet cover 3mm thick fixed with brass machine screw and cup washer. 2018 PWD 1139 579 Supply and fixing ofLED Tube Light batten fitting suitable for up to 1 X 22 watt LED tube light on surface complete in all respect. 2018 PWD 1413(A)CAT AA 580 Supply and fixing ofLED Street light Fittinghaving die cast aluminium body and diffuser with driver set suitable for 45 watt to 50 Watt. Confirming to IP 66 protection complete in all respect. 2018 PWD 1421CAT AA 581 Supply and fixing ofLED Street light Fittinghaving die cast aluminium body and diffuser with driver set suitable for 175 to 200 Watt. Confirming to IP 66Protection complete in all respects.2018 PWD 1425(A)CAT AA 582 Supply and fixing of3 Watt LED Path / Walkover luminaire having powder cotated die cast aluminium body with drive set . Confirming to IP 65 Protection complete in all respect. 2018 PWD 1441CAT AAA 583 Supply and fixing of 3 Watt to 6 Watt LED Spot/Spike light luminaire Confirming to IP 66 Protection complete in all respect. 2018 PWD 1441 (A) CAT AAA 584 Supply and fixing ofdecorative 8 to 16 Watt LEDbollard luminaire with driver set confirming to IP 65 protection complete in all respect. 2018 PWD 1442CAT AAA 585 Supply and fixing ofdecorative 40 to 45 Watt LED Post top indirect light luminaire having Pressure die cast aluminium body and Clear glass with driver set confirming to IP 65 and aboveprotection complete in all respect.2018 PWD 1443CAT AAA 586 Supply and fixing of 450mm size Exhaust fan of approved quality ISI mark (Bajaj/Havells/Usha/Crompton or equivalent make) complete with all respect as per sample approved by Engineer in charge including supply of all materials, labour and T&P etc requried for proper completion of the work as direction of E/I complete. (NSI ) 587 S/F of LED Bulb 9Watt bajaj or equivalent make as approved sample and make as per direction of Engineer in charge (NSI) 588 Supply and fixing of 200 mm Turbo ventilator Fan with ss Chimneycap & pipe of approved quality ISI mark (Bajaj/Havells/Usha/Crompton or equivalent make) complete with all respect as per sample approved by Engineer in charge including supply of all materials, labour and T&P etc requried for proper completion of the work as direction of E/I complete. (NSI ) 589 Providing and fixing 15 mm thick Industrial tiles size 600 x 600 mm to of Johnson Endura Meteor or approved make and colour using in different sizes (thickness to be specified by the manufacturer) conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete(NSI) 590 20-25 mm thick fine dressed Red sand stone flooring over 20 mm (average) thick base of cement mortar 1:5 (1 cement : 5 coarse sand) with joints finished flush.(NSI) 591 Providing/Laying 20-25 mm thick fine dressed Red sand stone flooring including supply of all materials, labour and T&P required for proper completion of work as perdirection of the Engineer-in charge.(NSI) 592 Providing and fixing prefab structure of size which does not require any structural steel frame at all heights of the existing building with following specifications: Manufactured by Epack polymers pvt ltd /Pronto panels Or Equivalent make.Walls: Outer & Inner walls made of 50 mm thick PUF insulated panels cladded with 0.5 mm thick PCGI sheet zinc coating 120 grams per sqm as per IS: 277. The wall panels shall be connected to each other with Cam Locks @ 1.00 m C/C The walls shall be connected to the the base platform with 1mm thick channels & 100 to 150mm long dash fasteners. The walls & ceiling shall be connected to each other by 1mm thick flashing as per the manufacturer specifications. Any number of vertical partitions are to be provided in the structure as required at site & as per the directions of the E-in-C complete. All the inner / outer gaps, if any, are to be filled with silicon, rubber gasket or any material required complete & directions of the Engineer in charge.Ceiling: Made of 50 mm thick PUF insulated panels cladded with 0.5 mm thick PCGI sheet zinc coating 120 grams per sqm as per IS: 277. The ceiling shall be extended from the wall on all sides by not less than 450mm & not more than 600mm with neccessary slopes in wall as required at the site & directions of the Engineer in charge complete. The outer edges of the roof shall be covered with the channel of the same material as of puff panel.Doors: Made out of 50 mm thick PUF insulated panels inner/outer side cladded with 0.5 mm thick PCGI sheet zinc coating 120 grams per sqm as per IS: 277. complete with providing & fixing all accessories like locks, SS hinges, SS Tower Bolts,SS handles of required size not more than 300mm.Windows: The frame work shall be of aluminium work (Powder coated aluminium (minimum thickness of powder coating 50 micron)) for doors, windows(Sliding/Openable as required with requisite handles, tower bolts,20mm dia SS curtain rod & any other fitting required ), ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be of thickness not less than 14gauge, smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing with 5.50mm thick glass / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. The outer surface shall have fly proof stainless steel grade 304 wire gauge, using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.50 mm all complete .Strengthing of door, window, ventilators & any other opening : Any opening provided will have the framework strengthened with 1mm thick MS Plate on all sides all complete & directions of the Engineer in charge.Measurements: Only the floor area of the pre fab outer structure will be measured for payment purpose.Conditions Rates include all lifts, leads, depths, material, labour, scaffolding, all heights for location, carriage, wastage, tools and plants and other all inputs for execution of the item. The colour of the panels for walls & ceiling should be got approved from the E-in-C prior to start of manufacturing of the structure. The Structure requires approx five partitions in the two structures besides two outer walls . Note: The zinc sheet of the puff panels can either be plain/corrugated on both sides or one side plain & one side corrugated upto any pitch in horizontal / verticals per the drawings & requirement at site. 593 Supply,Installation, testing & commissioning Battery 12 V 7 AH Exide or equivalent make for above fire alarm system. Complete as per direction of the Engineer-in charge. 594 Supply,Installation, testing & commissioning Response Indicator Agni Suraksha or equivalent make. Complete as per direction of the Engineer-in charge. 595 Supply,Installation, testing & commissioning Camera (3 MP) colour W Audio IP Dome Secureye or equivalent Indian make ,Lens-3.6mm. Complete as per direction of the Engineer-in charge. 596 Supply,Installation, testing & commissioning Camera (2 MP) IP Dome Falcon series Secureye or equivalent Indian make ,Lens-3.6mm. Complete as per direction of the Engineer-in charge. 597 Supply,Installation, testing & commissioning NVR 8 channelSecureye or equivalent Indian make, with 4TBHDD Hard Disk. Complete as per direction of the Engineer-in charge. 598 Supply,Installation, testing & commissioning Connector D link or equivalent make Complete as per direction of the Engineer-in charge. 599 Supply,Installation, testing & commissioning 8 Port POE Switch Secureye or equivalent Indian make Complete as per direction of the Engineer-in charge. 600 Supply,Installation, testing & commissioning Cable (CAT6) D link or equivalent make Complete as per direction of the Engineer-in charge. 601 Servicing of Air Conditioner (For Window/Split) by aurthorised service center complete in all respect including all labour and T&P. (CSI No. 20.30) 602 Servicing of Air Conditioner and filling of GAS (For Window/Split) by aurthorised service center complete in all respect including all labour and T&P. (CSI No. 20.31) 603 Supply and fixing of recess/ Surface/ Pendent mounting round 6 Watt 8 Watt LED Down Lighter having Powder coated die cast aluminium housing with heat sink, diffuser/Reflector and driver setcomplete in all respect. 1401 PWD CAT AA 604 Supply and fixing of recess/ Surface/ Pendent mounting round 10 to 15 Watt LED Down Lighter having Powder coated die cast aluminium housing with heat sink, diffuser/ Reflector and driver set complete in all respect. 1402 PWD CAT AA 605 Supply and fixing of 36 Watt to 46 Watt indoor Recess mounting LED Square Fitting for Armstrong Ceiling having Powder coated die cast aluminium housing body with extended heat sink and diffuser of Special Polycarbonate meterial and driver set complete in all respect.1406 PWD CAT AA 606 P/F of 30 W orevo make or equivalent make LED light 30 Watt over Hoarding frame along boundary wall of MD DVVNL Campus, 220 KV S/S Sikandra , Agra with necessary materials , labour, T&P etc required for proper completion of the work as per direction of Engineer in charge. (NSI) 607 Providing and fixing of 20 W Philips make or equivalent make LED Tube light 20 Watt with necessary materials labour, T&P etc requried for proper completion of the work as per direction of Engineer in charge (NSI) 608 S/F of 07 Watt LED bulb Syska or other equivalent make including cost of labour, T&P etc required for proper completion of the work (NSI) 609 Supply and fixing of vertical blinds with hanging/sliding rod of aluminium (vista or equivalent make), vertical cord for operation of blinds, L-type hooks, screws, gullies etc. including all T&P, labour etc required for proper completion of the work in all respect. (NSI) 610 Printing name and designation of occupants and other information on residence block/office building including preparation of the base with best quality synthetic enamel paint as directed by E/I including cost of all materials, labour and T&P etc. required for proper completion of work. (NSI) 611 Providing and fixing of Name plate Acrylic/Glow sign Sheet per mm thick without letter as per approved shade and design as per direction of Engineer in charge (NSI) 612 Providing and Pasting of Name plate letter cutting words laser machine without name plate including cost of necessary all fittings such as nut, screws, labour T&P etc requried for proper completion of the work as per direction of Engineer in charge (NSI)
Contract Date: Apr 23, 2026 Contract Value : 21.94 Lakh
Government Departments No of Bidders 3
Uttar Pradesh View Result →
48.
New and Renewable Energy #10170087 Price Bid
Annual Rate Contract For Eimco Elecon Make Spares. , Annual Rate Contract For Eimco Elecon Make Spares. , Arm Assembly Part No-917A070000001 , Bush, Metric Part No-Mbh100 / 116 / 70A , Bush ( Metric ) Part No-Mbh100 / 116 / 50A , Pin Part No-917A060000007 , Lock Plate Part No-917A060000001 , Hex Socket Head Cap Screw Part No-370-2411 , Spring Washer Part No-Mdw12sa , Grease Nipple Part No-Bp1fg , Pin Part No-917A060000014 , Lock Plate Part No-917A060000005 , Hex Socket Head Cap Screw Part No-370-2311 , Spring Washer Part No-Mdw10sa , Bush Part No-Mbh125_135_101 , Lever Assembly Part No-917A070000002 , Bush ( Metric ) Part No-Mbh125 / 145 / 85A , Bush ( Metric ) Part No-Mbh90 / 106 / 100A , Pin Part No-917A060000008 , Lock Plate Part No-917A060000002 , Hex Socket Head Cap Screw Part No-370-2311 , Spring Washer Part No-Mdw10sa , Grease Nipple Part No-Bp1fg , Bush Part No-Mbh90_98_60 , Link Assembly Part No-917A070000006 , Pin Part No-917A060000009 , Lock Plate Part No-907A060000006 , Hex Socket Head Cap Screw Part No-370-2311 , Spring Washer Part No-Mdw10sa , Grease Nipple Part No-Bp1fg , Bush ( Metric ) Part No-Mbh90 / 106 / 60A , Push Plate Bucket Assy. Part No-907B070000063 , Bucket Lip Part No-Eea0032174 , Twisting Bumper Part No-19Wl429091510 , Spacer Part No-19Wl425091303 , Washer Part No-19Wl425091304 , Hex Head Screw Part No-Mt12lg40g , Plate Part No-Eea0005530 , Locking Ring Part No-Eea0002017 , Lock Ring Part No-Ssla020000023 , Push Plate Upper Mac. Part No-907B020000089 , Push Plate Lower Part No-907B020000090 , Pin, Push Plate Lower Part No-907A060000008 , Pin, Push Plate Upper Part No-907A060000009 , Hex Head Bolt Part No-Mt10lg65g , Spring Washer Part No-Mdw10sa , Hex Nut, Nyloc Part No-Mt10ln , Push Plate Cylinder Part No-907B050000080 , Tube S / A-2 Part No-Eea0032090 , Piston Rod S / A Part No-Eea0032091 , Head End Cover Part No-Eea0032092 , Piston Part No-Eea0028785 , Retainer Part No-Eea0028786 , Snap Ring Part No-Eea0028787 , Grub Screw, Piston Part No-Eea0024567 , Gub Screw Part No-Eea0023564 , Circlip Part No-Eea0022817 , Spherical Bearing Part No-Stdc003 / 036 , Grease Nipple With Cap Part No-Eea0020796 , Bush Part No-Eea0023556 , Piston Seal Ring ( * ) Part No-Eea0023563 , Piston Wiper Ring ( * ) Part No-Eea0023562 , Piston Rod O-Ring ( * ) Part No-Eea0023561 , Back Up Ring ( * ) Part No-Eea0023560 , O-Ring ( * ) Part No-Eea0023555 , O-Ring ( * ) Part No-Eea0023554 , Step Seal ( * ) Part No-Eea0023558 , Rod Seal ( * ) Part No-Eea0023559 , Wiper Seal ( * ) Part No-Eea0023747 , Seal Kit ( * Items ) Part No-Eea0032093 , Pin ( Bucket ) Part No-907A060000004 , Pin, Upper Push Plate Part No-907A060000007 , Pin Part No-917A060000010 , Bush ( Metric ) Part No-Mbh100 / 116 / 55A , Bush ( Metric ) Part No-Mbh90 / 106 / 100A , Spacer Part No-811A060000106 , Lock Plate Part No-907A060000010 , Grease Nipple Part No-Bp1fg , Hex Socket Head Cap Screw Part No-370-2309 , Hex Socket Head Cap Screw Part No-370-2311 , Hex Head Bolt Part No-370-0326 , Spring Washer Part No-Mdw10sa , Hex Nut, Nyloc Part No-Mt10ln , Front Frame Assembly Part No-917A070000003 , Locking Ring Part No-Eea0003926 , Pin Assy. Part No-917A020000001 , Pin Part No-917A060000017 , Chain Part No-103451 , Hex Socket Head Cap Screw Part No-370-2409 , Spring Washer Part No-Mdw12sa , Pin Part No-917A060000015 , Hex Socket Head Cap Screw Part No-370-2329 , Spring Washer Part No-Mdw10sa , Hex Nut Part No-369-0110 , Pin Part No-917A060000012 , Lock Plate Part No-907A060000011 , Hex Socket Head Cap Screw Part No-370-2311 , Grease Nipple Part No-Bp1fg , Pin Part No-917A060000013 , Lock Plate Part No-917A060000002 , Lock Plate Part No-917A060000004 , Pin Part No-917A060000011 , Spherical Bearing Part No-Stdc003 / 056 , Seal Part No-Seg251 , O Ring Part No-Seg1099 , Hex Socket Head Cap Screw Part No-370-2232B , Wear Washer Part No-912B060000117 , Plate Part No-Eea0024855 , Bush ( Metric ) Part No-Mbh70 / 82 / 100A , Bush Part No-Mbh100_110_64 , Bush Part No-Mbh100_110_68 , Bush Part No-Mbh90_100_78 , Bush Part No-Mbh90_100_82 , Wheel Arch Lh Part No-917A020000010 , Wheel Arch Rh Part No-917A020000011 , Guard Part No-917A020000012 , Clamp Part No-917A020000009 , Front Axle Part No-917B050000011 , Axle Housing Part No-Eea0025425 , Breather Part No-Eea0025426 , Screw Plug Part No-Eea0025427 , Sealing Ring Part No-Eea0025428 , Screw Plug Part No-Eea0025429 , Sealing Ring Part No-Eea0025430 , Axle Shaft Part No-Eea0025431 , Wheel Stud Part No-Eea0025434 , Ring Part No-Eea0025435 , Radial Seal Ring Part No-Eea0025436 , Radial Seal Ring Part No-Eea0025437 , Tapered Roller Bearing Part No-Eea0025438 , Tapered Roller Bearing Part No-Eea0025439 , Ring Part No-Eea0025440 , Nut Part No-Eea0025441 , Hexagon Socket Screw Part No-Eea0025442 , O-Ring Part No-Eea0025443 , Sealing Ring Part No-Eea0025444 , Inner Disk Part No-Eea0025445 , Outer Disk Part No-Eea0025446 , Brake Group Kit Part No-907A070000085 , Piston Part No-Eea0025447 , Gasket Part No-Eea0025448 , Gasket Part No-Eea0025449 , Brake Carrier Part No-Eea0025450 , Brake Housing Part No-Eea0025451 , O-Ring Part No-Eea0025452 , O-Ring Part No-Eea0025453 , O-Ring Part No-Eea0025454 , Hexagon Socket Screw Part No-Eea0025455 , Hexagon Socket Screw Part No-Eea0025456 , Face Seal Part No-Eea0025457 , Screw Plug Part No-Eea0025458 , Sealing Ring Part No-Eea0025459 , Bleeding Socket Part No-Eea0025460 , Sealing Ring Part No-Eea0025461 , Bleeder Valve Part No-Eea0025462 , Compression Spring Part No-Eea0025463 , Compression Spring Part No-Eea0025464 , Intermediate Piece Part No-Eea0025465 , Piston Guide Ring Part No-Eea0025466 , Warning Label Part No-Eea0025467 , O-Ring Part No-Eea0025468 , Thread Bushing Part No-Eea0025469 , O-Ring Part No-Eea0025472 , Cap Part No-Eea0025473 , Planetary Housing Part No-Eea0025474 , O-Ring Part No-Eea0025475 , Screw Plug Part No-Eea0025476 , Disk Part No-Eea0025480 , Hexagon Socket Screw Part No-Eea0025481 , Sun Gear Part No-Eea0025482 , Bushing Part No-Eea0025483 , Hexagon Socket Screw Part No-Eea0025484 , Ring Part No-Eea0025485 , Planetary Gear Part No-Eea0025486 , Disk Part No-Eea0025487 , Ring Part No-Eea0025488 , Needle Bearing Part No-Eea0025489 , Planetary Pin Part No-Eea0025490 , Locking Pin Part No-Eea0025491 , Ring Gear Part No-Eea0025492 , Ring Gear Carrier Part No-Eea0025493 , Retainer Part No-Eea0025494 , Hexagon Screw Part No-Eea0025495 , O-Ring Part No-Eea0025496 , Differential And Carrier Assembly Part No-Eea0025497 , Drive Pinion Part No-Eea0025498 , Ring Gear Part No-Eea0025499 , Differential Housing Part No-Eea0025500 , Differential Spider Part No-Eea0025502 , Differential Side Gear Part No-Eea0025503 , Differential Pinion Part No-Eea0025504 , Bushing Part No-Eea0025505 , Hexagon Screw Part No-Eea0025507 , Tapered Roller Bearing Part No-Eea0025508 , Tapered Roller Bearing Part No-Eea0025509 , Differential Carrier Part No-Eea0025510 , Hexagon Screw Part No-Eea0025511 , Setting Ring Part No-Eea0025512 , Lock Plate Part No-Eea0025513 , Hexagon Screw Part No-Eea0025515 , Hexagon Screw Part No-Eea0025516 , Bolt Part No-Eea0025517 , Bolt Part No-Eea0025518 , Hexagon Nut Part No-Eea0025519 , Tapered Roller Bearing Part No-Eea0025520 , Bushing Part No-Eea0025521 , Tapered Roller Bearing Part No-Eea0025522 , Bearing Flange Part No-Eea0025523 , Cover Part No-Eea0025524 , Radial Seal Ring Part No-Eea0025525 , Hexagon Screw Part No-Eea0025526 , Compensation Plate Part No-Eea0025527 , Drive Flange Part No-Eea0025528 , Adjusting Nut Part No-Eea0025529 , Bearing Part No-Eea0025530 , Circlip Part No-Eea0025531 , Circlip Part No-Eea0025532 , Outer Disk Part No-Eea0025534 , Inner Disk Part No-Eea0025535 , Disk Part No-Eea0025536 , Disk Part No-Eea0025537 , O-Ring Part No-Eea0025538 , Disk Part No-Eea0025539 , Disk Part No-Eea0025540 , Ring Part No-Eea0025541 , Axle Bolt Part No-917A060000019 , Clamp Plate Part No-917A020000008 , Hex Head Bolt Part No-370-0405 , Spring Washer Part No-Mdw12sa , Hex Head Bolt Part No-370-0310 , Spring Washer Part No-Mdw10sa , Hex Nut Part No-369-0110 , Lock Wire ( As Required ) Part No-L400 , Spring Washer Part No-Mdw24sa , Spacer Part No-Eea0025806 , Spacer Part No-Eea0032217 , Spacer Part No-Eea0027058 , Spacer Part No-Eea0027059 , Roll Back Cylinder Part No-917B050000093 , Tube S / A Part No-Eea0027156 , Piston Rod S / A Part No-Eea0027157 , Head End Cover Part No-Eea0027158 , Piston Part No-Eea0027159 , Circlip Part No-Eea0025685 , Sph. Bearing Part No-Eea0025686 , Grease Nipple With Cap Part No-Eea0025669 , Grub Screw Part No-Eea0025670 , Rod Wear Ring ( * ) Part No-Eea0025688 , Piston Seal-Glydring ( * ) Part No-Eea0025689 , Piston Rod O Ring ( * ) Part No-Eea0025690 , Piston Rod Backup Ring ( * ) Part No-Eea0025691 , Hec O Ring ( * ) Part No-Eea0025692 , Hec Backup Ring ( * ) Part No-Eea0025693 , Piston Wear Ring ( * ) Part No-Eea0025694 , Rod Seal-Bs Type ( * ) Part No-Eea0025677 , Rod Wiper-H860 ( * ) Part No-Eea0025695 , Stop Tube O Ring ( * ) Part No-Eea0025696 , Step Seal ( * ) Part No-Eea0025676 , Steel Ball ( * ) Part No-Eea0025679 , Counter Balance Valve Part No-Eea0027160 , Grub Csrew Part No-Eea0029180 , Seal Kit ( * ) Marked Items Part No-Eea0027161 , Lift Cylinder Part No-917B050000094 , Tube S / A Part No-Eea0027162 , Piston Rod S / A Part No-Eea0027163 , Head End Cover Part No-Eea0027164 , Piston Part No-Eea0027165 , Circlip Part No-Eea0025667 , Sph Bearing Part No-Eea0025668 , Grease Nipple With Cap Part No-Eea0025669 , Grub Screw Part No-Eea0025670 , Piston Wear Ring ( * ) Part No-Eea0025672 , Piston Seal, Glydring ( * ) Part No-Eea0025673 , O-Ring, Piston Rod ( * ) Part No-Eea0022809 , Piston Rod Back Up Ring ( * ) Part No-Eea0022810 , Hec O Ring ( * ) Part No-Eea0025674 , Hec Backup Ring ( * ) Part No-Eea0025675 , Step Seal ( * ) Part No-Eea0025676 , Rod Seal-Bs Type ( * ) Part No-Eea0025677 , Rod Wiper-860 ( * ) Part No-Eea0025678 , Steel Ball ( * ) Part No-Eea0025679 , Counter Balance Valve Part No-Eea0027167 , Seal Kit ( * ) Marked Items Part No-Eea0027168 , Rear Frame Part No-907C020000099 , Plate, Switch Mtg Part No-Eea0002375 , Coupling Part No-Stdd017 / 015 , Coupling ( 1Bsp ) Part No-Stdd017 / 16 , Clamp, Half Part No-912B060000098 , Hex Head Bolt Part No-370-0402 , Plate Part No-Eea0031318 , Hex Nut Part No-369-0116 , Bracket Part No-907A070000082 , Plate Part No-Eea0033367 , Flat Washer Part No-Maw10ga , Spring Washer Part No-Mdw10sa , Hex Head Bolt Part No-370-0306 , Threaded Boss Part No-Eea0033366 , Spring Washer Part No-Mdw10sa , Fuel Level Gauge Part No-912B050000314 , Plug Part No-1027A050000003 , Rear Axle Part No-917B050000012 , Axle Housing Part No-Eea0025425 , Breather Part No-Eea0025426 , Screw Plug Part No-Eea0025427 , Planetary Group Kit Part No-907A070000086 , Sealing Ring Part No-Eea0025428 , Screw Plug Part No-Eea0025429 , Sealing Ring Part No-Eea0025430 , Axle Shaft Part No-Eea0025431 , Axle Shaft Part No-Eea0025432 , Wheel Stud Part No-Eea0025434 , Hub Reduction Group Kit Part No-907A070000087 , Ring Part No-Eea0025435 , Radial Seal Ring Part No-Eea0025436 , Radial Seal Ring Part No-Eea0025437 , Tapered Roller Bearing Part No-Eea0025438 , Tapered Roller Bearing Part No-Eea0025439 , Ring Part No-Eea0025440 , Nut Part No-Eea0025441 , Hexagon Socket Screw Part No-Eea0025442 , O-Ring Part No-Eea0025443 , Sealing Ring Part No-Eea0025444 , Inner Disk Part No-Eea0025445 , Outer Disk Part No-Eea0025446 , Piston Part No-Eea0025447 , Gasket Part No-Eea0025448 , Gasket Part No-Eea0025449 , Brake Carrier Part No-Eea0025450 , Brake Housing Part No-Eea0025451 , O-Ring Part No-Eea0025452 , O-Ring Part No-Eea0025453 , O-Ring Part No-Eea0025454 , Hexagon Socket Screw Part No-Eea0025455 , Hexagon Socket Screw Part No-Eea0025456 , Face Seal Part No-Eea0025457 , Screw Plug Part No-Eea0025458 , Sealing Ring Part No-Eea0025459 , Bleeding Socket Part No-Eea0025460 , Sealing Ring Part No-Eea0025461 , Bleeder Valve Part No-Eea0025462 , Compression Spring Part No-Eea0025463 , Compression Spring Part No-Eea0025464 , Intermediate Piece Part No-Eea0025465 , Piston Guide Ring Part No-Eea0025466 , Warning Label Part No-Eea0025467 , O-Ring Part No-Eea0025468 , Thread Bushing Part No-Eea0025469 , O-Ring Part No-Eea0025472 , Cap Part No-Eea0025473 , Planetary Housing Part No-Eea0025474 , O-Ring Part No-Eea0025475 , Screw Plug Part No-Eea0025476 , Disk Part No-Eea0025480 , Hexagon Socket Screw Part No-Eea0025481 , Sun Gear Part No-Eea0025482 , Bushing Part No-Eea0025483 , Hexagon Socket Screw Part No-Eea0025484 , Ring Part No-Eea0025485 , Planetary Gear Part No-Eea0025486 , Disk Part No-Eea0025487 , Ring Part No-Eea0025488 , Needle Bearing Part No-Eea0025489 , Planetary Pin Part No-Eea0025490 , Locking Pin Part No-Eea0025491 , Ring Gear Part No-Eea0025492 , Ring Gear Carrier Part No-Eea0025493 , Retainer Part No-Eea0025494 , Hexagon Screw Part No-Eea0025495 , O-Ring Part No-Eea0025496 , Differential And Carrier Assembly Part No-Eea0025470 , Drive Pinion Part No-Eea0025498 , Ring Gear Part No-Eea0025499 , Differential Housing Part No-Eea0025500 , Differential Housing Part No-Eea0025501 , Hexagon Screw Part No-Eea0025507 , Tapered Roller Bearing Part No-Eea0025508 , Differential Carrier Part No-Eea0025510 , Hexagon Screw Part No-Eea0025511 , Setting Ring Part No-Eea0025512 , Lock Plate Part No-Eea0025513 , Hexagon Screw Part No-Eea0025515 , Hexagon Screw Part No-Eea0025516 , Bolt Part No-Eea0025517 , Bolt Part No-Eea0025518 , Hexagon Nut Part No-Eea0025519 , Tapered Roller Bearing Part No-Eea0025520 , Bushing Part No-Eea0025521 , Tapered Roller Bearing Part No-Eea0025522 , Bearing Flange Part No-Eea0025523 , Cover Part No-Eea0025524 , Radial Seal Ring Part No-Eea0025525 , Hexagon Screw Part No-Eea0025526 , Compensation Plate Part No-Eea0025527 , Drive Flange Part No-Eea0025528 , Adjusting Nut Part No-Eea0025529 , Bearing Part No-Eea0025530 , Circlip Part No-Eea0025531 , Circlip Part No-Eea0025532 , Nospin Differential Part No-Eea0025533 , O-Ring Part No-Eea0025538 , Disk Part No-Eea0025539 , Disk Part No-Eea0025540 , Credle Kit For Axle Part No-907A070000084 , Plate Part No-Eea0025542 , Ring Part No-Eea0025543 , Disk Part No-Eea0025544 , Disk Part No-Eea0025545 , Bushing Part No-Eea0025546 , Bracket Part No-Eea0025547 , Disk Part No-Eea0025548 , Plate Part No-Eea0025549 , Plate Part No-Eea0025550 , Plate Part No-Eea0025551 , Hexagon Screw Part No-Eea0025552 , Hexagon Screw Part No-Eea0025553 , Hexagon Screw Part No-Eea0025554 , O-Ring Part No-Eea0025555 , Grease Nipple Part No-Eea0025556 , Locking Pin Part No-Eea0025557 , Sunk Screw Part No-Eea0025558 , Hex Head Bolt Part No-917A060000023 , Spring Washer Part No-Mdw20sa , Dowelpin Part No-Mkb30m40 , Hex Head Bolt Part No-917A060000024 , Steering Cylinder Part No-917B050000008 , Tube S / A Part No-Eea0025637 , Piston Rod S / A Part No-Eea0025638 , Head End Cover Part No-Eea0022798 , Piston Part No-Eea0025639 , Circlip Part No-Eea0022800 , Spherical Bearing Part No-Eea0022799 , Grease Nipple With Cap Part No-Eea0020796 , Grub Screw Part No-Eea0022801 , Snap Ring Part No-Eea0025634 , Piston Wear Ring ( * ) Part No-Eea0022803 , Piston Seal ( * ) Part No-Eea0022802 , Piston Rod O Ring ( * ) Part No-Eea0022804 , Back Up Ring ( * ) Part No-Eea0022805 , O-Ring, Piston Rod ( * ) Part No-Eea0022809 , Hec B / U Ring ( * ) Part No-Eea0025698 , Rod Wear Ring ( * ) Part No-Eea0022808 , Rod Seal ( * ) Part No-Eea0022807 , Wiper ( * ) Part No-Eea0025635 , Seal Kit ( * ) Marked Items Part No-Eea0025645 , Spacer Part No-907A020000046 , Pin Part No-917A060000016 , Lock Plate Part No-822A060000013 , Hex Socket Head Cap Screw Part No-370-2311 , Pin Assy. Part No-917A020000002 , Pin Part No-917A060000018 , R. Bar Part No-Eea0012035 , Pin ( F.F.-R.F. ) Part No-907B060000005 , Clamp Half Part No-912B060000115 , Hex Head Bolt Part No-370-0631 , Hex Nut Part No-369-0116 , Spring Washer Part No-Mdw16sa , Hex Head Bolt Part No-370-0236 , Spring Washer Part No-Mdw08sa , Cover Part No-811B020000150 , Gasket Part No-811B050000067 , Tank Relief Cartridge Part No-613M000001081 , Bonded Seal Part No-Sc011 / 013 , Steel Ball Part No-Gr6 , Bonded Seal Part No-Sc011 / 019 , Drain Cock, Valve Part No-Bp2rve , Suction Strainer ( 40 Mesh ) Part No-625B050000122 , Hex Bushing Part No-Bp11bb10 , Oil Level Window Part No-241A000000284 , Bonded Seal Part No-Sc011 / 027 , Grease Nipple Part No-Bp1fg , Lock Plate Part No-912A020000551 , Hex Head Bolt Part No-370-0306 , Flat Washer Part No-Maw08ga , Lock Wire ( As Required ) Part No-L400 , Plate Part No-Eea0025704 , Spacer Part No-Eea0025803 , Guard Part No-Eea0028536 , Hex Head Bolt Part No-370-0237 , Tank Breather Part No-917A050000078 , Clamp Plate Part No-Eea0026327 , Hex Head Bolt Part No-370-0409 , Hex Nut Part No-369-0112 , Spring Washer Part No-Mdw12sa , Flat Washer Part No-Maw12ga , Seat- Hyd Suspension Part No-907A050000093 , Hex Head Bolt Part No-370-0240 , Fuel Level Guard Part No-907A020000043 , Bush Part No-Mbh100_120_50 , Bush Part No-Mbh100_120_45 , Bush Part No-Mbh100_120_61 , Canopy Assembly Part No-907A070000007 , Threaded Boss Part No-811A060000056 , Threaded Boss Part No-016A000099060 , Eimco Logo Assy. Part No-19Wl020000262 , Logo E ( Big ) Part No-19Wl020000263 , Logo E Small Part No-19Wl020000264 , Name Plate Part No-Eeb0018997 , Clamp Part No-Eea0007780 , Plate Part No-Eea0027695 , Beacon Mtg. Bkt. Part No-910A020000114 , Flashing Light Bracket Part No-Eea0031660 , Hex Head Bolt Part No-370-0204 , Spring Washer Part No-Mdw06sa , Hex Head Bolt Part No-370-1013B , Spring Washer Part No-Mdw24sa , Hex Head Bolt Part No-370-1015 , Hex Nut Part No-369-0124 , Hex Head Bolt Part No-370-1009 , Diesel Engine Part No-907B050000005 , Engine Bracket Part No-907A020000059 , Engine Bracket, Rh Part No-907B020000060 , Engine Bracket, Lh Part No-907B020000061 , Avm ( Engine ) Part No-19Wl050000865 , Avm, Engine Part No-910A050000025 , Hex Head Bolt Part No-370-0612 , Hex Head Bolt Part No-370-0623 , Spacer Part No-Eea0027233 , Hex Head Bolt Part No-370-1026 , Hex Nut, Nyloc Part No-Mt24ln , Spring Washer Part No-Mdw16sa , Hex Nut Part No-369-0124 , Flat Washer Part No-Maw24ga , Washer, Avm Part No-907A020000068 , Transmission Part No-917B050000002 , Pipe Plug Part No-Eea0026623 , Assembly-Conv Housing & Tube Part No-Eea0022609 , Sleeve Part No-Eea0013072 , Tube Slleve Part No-Eea0005696 , Sleeve Part No-Eea0008045 , Sleeve Lock Part No-Eea0008046 , Lock Washer Part No-Eea0013073 , Tube Clip Screw Part No-Eea0005690 , O Ring Part No-Eea0013079 , Spacer Ring Part No-Eea0013080 , Tube Assy. Part No-Eea0013081 , Lock Washer Part No-Eea0005729 , Screw, Cover Part No-Eea0010946 , Tube Clip Part No-Eea0008041 , Rev. Tube Assy. Part No-Eea0011579 , O Ring Part No-Eea0013082 , Lube Tube Assy. Part No-Eea0011578 , Tube Assy. Part No-Eea0011580 , Supply Tube Part No-Eea0011583 , Sleeve Part No-Eea0013072 , Tube Slleve Part No-Eea0005696 , Sleeve Part No-Eea0008045 , Sleeve Lock Part No-Eea0008046 , Lock Washer Part No-Eea0013073 , Tube Clip Screw Part No-Eea0005690 , Air Breather Part No-Eea0005680 , Elbow Part No-Eea0011641 , Breather Bushing Part No-Eea0011556 , Lock Washer Part No-Eea0005685 , Screw-Conv Hsg To Trans Case Part No-Eea0026624 , Lockwasher-Pump Mounting Screw Part No-Eea0026625 , Screw-Conv Hsg To Trans Case Part No-Eea0026626 , O Ring Part No-Eea0013079 , Spacer Ring Part No-Eea0013080 , Tube Assy. Part No-Eea0013081 , Lock Washer Part No-Eea0005729 , Screw, Cover Part No-Eea0010946 , Tube Clip Part No-Eea0008041 , Rev. Tube Assy. Part No-Eea0011579 , O Ring Part No-Eea0013082 , Lube Tube Assy. Part No-Eea0011578 , Tube Assy. Part No-Eea0011580 , Supply Tube Part No-Eea0011583 , Screw-Conv Hsg To Trans Case Part No-Eea0026627 , Gasket Part No-Eea0008057 , Pin Part No-Eea0023186 , Spacer Part No-Eea0023187 , Seal Part No-Eea0005936 , Cover-Converter Housing Front Part No-Eea0026655 , Screw Part No-Eea0011557 , Stud Nut Part No-Eea0013069 , Stud ( Not Shown ) Part No-Eea0019387 , Lock Washer Part No-Eea0005729 , Gasket Part No-Eea0005917 , Hose Fitting Part No-Eea0013102 , Hose Fitting Part No-Eea0013103 , Trans. Case & Tube Assy. Part No-Eea0013750 , Tube Assy. Part No-Eea0013110 , Clip Part No-Eea0013109 , Tube Slleve Part No-Eea0005696 , Pressure Tube Part No-Eea0008060 , Rivet Part No-Eea0008072 , Cap Screw Part No-Eea0019350 , Washer Part No-Eea0013112 , Oring, Suction Line Part No-Eea0005966 , Baffle, Oil Part No-Eea0008073 , Baffle, Oil Part No-Eea0008074 , O Ring Part No-Eea0011654 , Pressure Tube Part No-Eea0011587 , Tube Part No-Eea0011588 , Retainer Ring Part No-Eea0008035 , Oil Distributor Part No-Eea0011609 , Ball Part No-Eea0019351 , Tube Assy. Part No-Eea0013110 , Clip Part No-Eea0013109 , Tube Slleve Part No-Eea0005696 , Pressure Tube Part No-Eea0008060 , Rivet Part No-Eea0008072 , Cap Screw Part No-Eea0019350 , Washer Part No-Eea0013112 , O Ring Part No-Eea0026628 , Baffle, Oil Part No-Eea0008073 , Baffle, Oil Part No-Eea0008074 , O Ring Part No-Eea0026629 , Pressure Tube Part No-Eea0011587 , Tube Part No-Eea0011588 , Retainer Ring Part No-Eea0008035 , Oil Distributor Part No-Eea0011609 , Ball Part No-Eea0019351 , Dowel Pin Part No-Eea0008061 , O Ring Part No-Eea0026630 , Magnetic Drain Plug Part No-Eea0005708 , Plug-Oil Level / Plug-Lockup Port Part No-Eea0026631 , Screen Assembly Part No-Eea0005688 , Screen Assy. Gasket Part No-Eea0005687 , Cover Part No-Eea0013751 , Gasket Part No-Eea0008075 , Capscrew Part No-Eea0026633 , Lockwasher-Pump Mounting Screw Part No-Eea0026625 , Nut Part No-Eea0026634 , Stud Part No-Eea0011561 , Pipe Plug Part No-Eea0005683 , Capscrew Part No-Eea0026635 , Lockwasher Part No-Eea0026636 , Assy-Stator Support Sleeve Part No-Eea0011616 , Turbine Shaft Part No-Eea0013121 , Piston Ring Part No-Eea0008293 , Bearing Part No-Eea0019389 , Snap Ring Part No-Eea0008050 , Piston Ring Part No-Eea0008278 , Oil Baffle Part No-Eea0011573 , Seal Ring Part No-Eea0011586 , Ring, Oil Baffle Retaining Part No-Eea0010858 , Turbine Hub Part No-Eea0013122 , Snap Ring Part No-Eea0008268 , Reaction Member Part No-Eea0013123 , Spacer Part No-Eea0011571 , Snap Ring Part No-Eea0013124 , Bearing Part No-Eea0013125 , Impeller Hub Part No-Eea0013126 , O Ring Part No-Eea0013127 , Impeller Part No-Eea0026638 , Backing Ring Part No-Eea0013129 , Screw Part No-Eea0013130 , Turbine Part No-Eea0011622 , Screw Part No-Eea0008272 , Cap Screw Part No-Eea0019390 , Oring Part No-Eea0005753 , Impeller Cover Part No-Eea0013132 , Capscrew Part No-Eea0026639 , Lock Washer Part No-Eea0005729 , Bearing Part No-Eea0013133 , Bearing Washer Part No-Eea0013134 , Snap Ring Part No-Eea0013135 , O Ring Part No-Eea0013136 , Input Shaft Part No-Eea0013137 , Capscrew Part No-Eea0026640 , Shaft Bearing Part No-Eea0011568 , Lock Washer Part No-Eea0005685 , Screw Part No-Eea0011642 , Gear Part No-Eea0013139 , Bearing Support Part No-Eea0011574 , Bearing Ball Part No-Eea0019391 , Ring - Snap Part No-Eea0019392 , Ring-Span Part No-Eea0008296 , Gear-Imppeller Hub - 46T Part No-Eea0013084 , Gear- Pump Drive Idler 47T Part No-Eea0019393 , Support- Pump Drive Idler Part No-Eea0019394 , Bearing- Ball 6309 Part No-Eea0019395 , Snap-Ring-Internal Part No-Eea0019376 , Gear Clutch Driven 25T Part No-Eea0026653 , Gear-High Range 52T Part No-Eea0011585 , Gear-Drive Low 4Th. 26T Part No-Eea0013737 , Gear-2Nd 30T Part No-Eea0011621 , Reverse 2Nd Shaft Piston Ring Part No-Eea0005807 , Front Bearing Retaing Ring Part No-Eea0005808 , Washer Part No-Eea0013140 , End Plate Balend Plate Ball Part No-Eea0013141 , Front Bearing Part No-Eea0013142 , Bearing Part No-Eea0023197 , Retaninng Ring Part No-Eea0023198 , Baffle Ring Part No-Eea0008085 , Retainer Ring Part No-Eea0008086 , End Plate Part No-Eea0013143 , Clutch Outer Disc Part No-Eea0008088 , Inner Disc Part No-Eea0013144 , Assy. Clutch Piston & Seals Part No-Eea0019377 , Outer Seal Part No-Eea0008091 , Inner Seal Part No-Eea0008092 , Seal-Clutch Piston Metering Part No-Eea0019354 , Assy-Rev & 3Rd Shaft Part No-Eea0023199 , Seal-Clutch Piston -Outer Part No-Eea0022170 , Assy-Clutch Piston & Seals Part No-Eea0022169 , End Plate Part No-Eea0013149 , Retainer Spring Part No-Eea0022171 , Washer Assy. Part No-Eea0013150 , Snap Ring Retainer Part No-Eea0008098 , Spring Retainer Snap Ring Part No-Eea0005820 , Low Speed Gear Bearing Part No-Eea0005826 , Spring Retainer Part No-Eea0008101 , Return Spring Part No-Eea0008102 , Spring Retainer Part No-Eea0008103 , Bearing Part No-Eea0008104 , Snap Ring Part No-Eea0008105 , Spacer Part No-Eea0008106 , Shield Out Part No-Eea0008107 , Rear Bearing Part No-Eea0013151 , Retainer Ring Part No-Eea0008109 , Reverse 2Nd Shaft Piston Ring Part No-Eea0005807 , Front Bearing Retaing Ring Part No-Eea0005808 , Washer Part No-Eea0013140 , End Plate Balend Plate Ball Part No-Eea0013141 , Front Bearing Part No-Eea0013142 , Front Bearing Snap Ring Part No-Eea0005809 , Bearing Part No-Eea0023197 , Retaninng Ring Part No-Eea0023198 , Baffle Ring Part No-Eea0008085 , Low Speed Gear Bearing Part No-Eea0005826 , Spring Retainer Snap Ring Part No-Eea0005820 , Snap Ring Retainer Part No-Eea0008098 , Washer Assy. Part No-Eea0013150 , Retainer Spring Part No-Eea0022171 , Ring Retainer Part No-Eea0013162 , Sanp Ring Part No-Eea0013163 , Spring Retainer Part No-Eea0008103 , Return Spring Part No-Eea0008102 , Spring Retainer Part No-Eea0008101 , Retainer Ring Part No-Eea0008086 , End Plate Part No-Eea0013143 , Clutch Outer Disc Part No-Eea0008088 , Inner Disc Part No-Eea0013144 , Assy. Clutch Piston & Seals Part No-Eea0019377 , Outer Seal Part No-Eea0008091 , Inner Seal Part No-Eea0008092 , Seal-Clutch Piston Metering Part No-Eea0019354 , Assy.-Fwd & 2Nd Shaft, Hub, Drum & Plug Part No-Eea0023243 , Seal-Clutch Piston -Outer Part No-Eea0022170 , Assy-Clutch Piston & Seals Part No-Eea0022169 , End Plate Part No-Eea0013149 , Gear-Clutch Driven 27T Part No-Eea0023193 , Gear-2Nd 30T Part No-Eea0011621 , Assy-Low Shaft, Hub, Drum & Plug Part No-Eea0019357 , Assy-Low Hub & Drum Part No-Eea0019358 , O Ring Part No-Eea0013178 , Retaining Ring Part No-Eea0013175 , Shaft Part No-Eea0013753 , Plug Part No-Eea0013179 , Assy-Low Hub & Drum Part No-Eea0019358 , O Ring Part No-Eea0013178 , Retaining Ring Part No-Eea0013175 , Shaft Part No-Eea0013753 , Plug Part No-Eea0013179 , Seal-Clutch Piston Metering Part No-Eea0019354 , Assy-Clutch Piston & Seals Part No-Eea0019359 , Inner Seal Part No-Eea0008092 , Seal-Clutch Piston -Outer Part No-Eea0022170 , Clutch Inner Disc Part No-Eea0008115 , Clutch Outer Disc Part No-Eea0008088 , End Plate Part No-Eea0008087 , Retainer Ring Part No-Eea0008086 , Spring Part No-Eea0013167 , Retainer Spring Part No-Eea0013168 , Bearing Spacer Part No-Eea0013170 , Spring Retainer Part No-Eea0008124 , Snap Ring Part No-Eea0008050 , Ring Retainer Part No-Eea0013169 , Gear ( 54T ) Part No-Eea0013752 , Bearing Assy. Part No-Eea0013171 , Piston Ring Part No-Eea0008227 , Pilot Bearing Part No-Eea0008130 , Bearing Cup Part No-Eea0008156 , Bearing Cone Part No-Eea0013191 , Cap Part No-Eea0013756 , Capscrew Part No-Eea0026639 , Lock Washer Part No-Eea0005729 , Lock Washer Part No-Eea0005729 , Pipe Plug Part No-Eea0005683 , O Ring Part No-Eea0026644 , O Ring Part No-Eea0026645 , Bearing Cup Part No-Eea0014098 , Bearing Cone Part No-Eea0013173 , Seal-Clutch Piston Metering Part No-Eea0019354 , Inner Seal Part No-Eea0008092 , Snap Ring Part No-Eea0013135 , Assy-4Th Hub & Drum Part No-Eea0019360 , Assy-Idler Shaft, Gear And Plugs Part No-Eea0019361 , Shaft And Bearing Assy. Part No-Eea0013189 , Bearing Lock Ball Part No-Eea0008138 , Locating Ring Part No-Eea0008139 , Washer Part No-Eea0013764 , Disc Hub Nut Part No-Eea0013224 , Gasket Part No-Eea0008141 , Cap Part No-Eea0013765 , Ber.Cap Stud Lock Washer Part No-Eea0005861 , Screw Part No-Eea0013766 , Outer Seal Part No-Eea0008091 , Assy-Clutch Piston & Seals Part No-Eea0019359 , Clutch Outer Disc Part No-Eea0008088 , Inner Disc Part No-Eea0013144 , End Plate Part No-Eea0008087 , Retainer Ring Part No-Eea0008086 , Spring Retainer Part No-Eea0008101 , Return Spring Part No-Eea0008102 , Spring Retainer Part No-Eea0008103 , Snap Ring Part No-Eea0011575 , Impeller Hub Gear Bearing Part No-Eea0005738 , Gear-4Th Clutch & Hub 23T Part No-Eea0019363 , Spacer Part No-Eea0011595 , Bearing Part No-Eea0011566 , Piston Ring Part No-Eea0008224 , Oil Seal Part No-Eea0013190 , Bearing Cap Part No-Eea0008145 , O Ring Part No-Eea0026648 , Bearing Cup Part No-Eea0011629 , Bearing Cone Part No-Eea0013191 , Gear Spacer Part No-Eea0013192 , Output Shaft Part No-Eea0013193 , Bearing Cup Part No-Eea0008156 , O Ring Part No-Eea0026649 , O Ring Part No-Eea0026650 , Ber.Cap Stud Lock Washer Part No-Eea0005861 , Capscrew Part No-Eea0026651 , Capscrew Part No-Eea0026652 , Gasket Part No-Eea0011617 , O Ring Part No-Eea0013311 , O Ring Part No-Eea0005695 , O Rong Part No-Eea0013214 , Stud Part No-Eea0011577 , Gasket Part No-Eea0011637 , Lock Washer Part No-Eea0005685 , Bearing Cap Stud Nut Part No-Eea0005836 , Pressure Regulator Part No-Eea0013213 , Plug-Oil Level / Plug-Lockup Port Part No-Eea0026631 , Valve Seat Part No-Eea0011600 , Spacer Part No-Eea0011601 , Safety Valve Plunger Part No-Eea0013198 , Valve Spring Part No-Eea0008250 , O Ring Part No-Eea0026656 , Valve Stop Part No-Eea0011569 , Roll Pin Part No-Eea0011652 , Valve Stop Part No-Eea0008243 , O Ring Part No-Eea0026657 , Valve Piston Part No-Eea0011638 , Valve Spring , Inner Part No-Eea0008247 , Valve Spring Outer Part No-Eea0011613 , Oil Seal Part No-Eea0013212 , Roll Pin Part No-Eea0011602 , Charging Pump & Cover Part No-Eea0026646 , Assyembly Charging Pump 20 Gpm Part No-Eea0022635 , Lockwasher Part No-Eea0026658 , Capscrew Part No-Eea0026659 , Gasket Part No-Eea0013215 , Pump Cover Part No-Eea0013216 , Gasket Part No-Eea0013780 , Capscrew Part No-Eea0026683 , Lock Washer Part No-Eea0005729 , Assembly-Control Valve Cover Part No-Eea0026661 , Plug Part No-Eea0021168 , Gasket Part No-Eea0013780 , Plug-Filler Part No-Eea0021190 , Spool Part No-Eea0013781 , Pin Part No-Eea0013782 , Accumulator Spring Inner Part No-Eea0005908 , Spring Part No-Eea0013783 , Spring Part No-Eea0026662 , Fitting Plug Part No-Eea0026663 , Spool Part No-Eea0026664 , Spring Part No-Eea0026665 , Pin Part No-Eea0026666 , Shuttle Valve-Bottom Part No-Eea0013786 , Ctrl Valve & Hsg. Assy. Part No-Eea0013770 , O Ring Part No-Eea0026667 , O Ring Part No-Eea0026668 , O Ring Part No-Eea0026669 , O Ring Part No-Eea0026670 , O Ring Part No-Eea0026671 , Assy-Spool Type Solenoid Cartrigde Part No-Eea0026672 , Fitting-Plug, O Ring Seal Part No-Eea0026703 , O Ring Part No-Eea0026673 , Spring Part No-Eea0013768 , Spool-Regulator Part No-Eea0026674 , Plug Part No-Eea0013179 , Cover-Solenoid Part No-Eea0026676 , Cover-Solenoid Part No-Eea0026677 , Capscrew Part No-Eea0026678 , Lock Washer Part No-Eea0013073 , Retainer-Wire Part No-Eea0026679 , Retainer Part No-Eea0026680 , Spacer-Wire Retainer Part No-Eea0026681 , Gasket Part No-Eea0013767 , Capscrew Part No-Eea0026683 , Lock Washer Part No-Eea0005729 , Flange Part No-Eea0011972 , O Ring, Flange Part No-Eea0010959 , Washer Part No-Eea0011872 , Nut Part No-Eea0008317 , Flange Part No-Eea0013732 , O Ring Part No-Eea0013065 , Washer Part No-Eea0013064 , Nut Part No-Eea0008140 , Pump Adaptor Part No-Eea0026684 , Gasket Part No-4697203 , Lockwasher Part No-Eea0026636 , Capscrew Part No-Eea0026686 , Pump Drive Sleeve & Snap Ring Part No-Eea0019402 , Pump Drive Hole Cover Part No-Eea0019386 , Snap Ring Part No-Eea0013814 , Snap Ring Part No-Eea0008309 , Gasket Part No-Eea0011597 , Adaptor-Pump Part No-Eea0026688 , Lock Washer Part No-Eea0005685 , Capscrew Part No-Eea0026689 , Lock Washer Part No-Eea0005729 , Capscrew Part No-Eea0026690 , Pump Drive Sleeve And Snap Ring Assembly Part No-Eea0026691 , Sleeve Pump Drive Part No-Eea0026692 , Snap Ring Part No-Eea0008309 , Kit-Connector, Wire & Seal Part No-Eea0026654 , Taps - Oil Fill Part No-Eea0013091 , Cab Control Part No-Eea0025805 , Duel Element Filter Assy. Part No-Eea0026879 , Filter Head Assy. Part No-Eea0026880 , Electrical Indicator Assy. Part No-Eea0026881 , Indicator Seal & Connector Nut Kit Part No-Eea0026882 , Filter Element Assy. Part No-Eea0026790 , Bracket Part No-917A020000043 , Bracket Part No-917A020000044 , Bracket Part No-917A020000045 , Bracket Part No-917A020000046 , Hex Head Bolt Part No-917A060000022 , Spring Washer Part No-W12gf , Dip Stick Part No-912A050000080 , Lock Wire ( As Required ) Part No-L400 , Reducer ( Bsp-Npt ) , M / M Part No-Sc089 / 046 , Elbow, 90 Degree M / F Part No-Se012 / 026 , Hose Assembly Part No-623D02584 / 148 , Bonded Seal Part No-Sc011 / 024 , Elbow, Street 90 Degree M / F Part No-Bp6blb , Pipe Part No-Eea0026870 , Pillow Block Bearing Part No-917A050000016 , Drive Line ( Front ) Part No-912B050000206 , Spider Assy. ( 7C ) Part No-912A050000208 , Drive Line ( Articulation ) Part No-912B050000218 , Spider Assy. ( 7C ) Part No-912A050000208 , Drive Line ( Tr. To Rear Axle ) Part No-917B050000020 , Hex Head Bolt Part No-T8hg40 , Spring Washer Part No-W8gfb , Hex Head Bolt Part No-370-0612 , Hex Nut Part No-369-0116 , Spring Washer Part No-Mdw16sa , Flat Washer Part No-Maw16ga , Hex Head Bolt Part No-370-0815 , Hex Nut Part No-369-0120 , Spring Washer Part No-Mdw20sa , Hex Head Bolt Part No-T6hg32 , Spring Washer Part No-W6gf , Upbox Part No-917B050000090 , Radial Seal Ring Part No-Eea0027541 , Drive Flange Part No-Eea0027542 , Hexagon Screw Part No-Eea0027543 , Disk Part No-Eea0027544 , Disk Part No-Eea0027545 , Housing Part No-Eea0027546 , Screw Plug Part No-Eea0027547 , Sealing Ring Part No-Eea0027548 , Screw Plug Part No-Eea0027549 , Breather Part No-Eea0027550 , Plate Part No-Eea0027551 , Hexagon Socket Screw Part No-Eea0027552 , Sleeve Part No-Eea0027553 , Hexagon Screw Part No-Eea0027554 , Radial Seal Ring Part No-Eea0027555 , Angle Piece Part No-Eea0027556 , Cover Part No-Eea0027557 , Gear Wheel Part No-Eea0027558 , Pinion Part No-Eea0027559 , Shaft Part No-Eea0027560 , Hexagon Socket Screw Part No-Eea0027561 , Bearing Part No-Eea0027562 , Bearing Part No-Eea0027563 , Cover Part No-Eea0027564 , Hexagon Screw Part No-Eea0027565 , Pinion Part No-Eea0027566 , Grooved Ball Bearing Part No-Eea0027567 , Grooved Ball Bearing Part No-Eea0027568 , Flange Part No-Eea0027569 , Hexagon Screw Part No-Eea0027570 , Cover Part No-Eea0027571 , Hexagon Screw Part No-Eea0027572 , Driver Part No-Eea0027573 , Pipe Part No-Eea0027574 , Sealing Ring Part No-Eea0027575 , O-Ring Part No-Eea0027576 , O-Ring Part No-Eea0027577 , Coupling Part No-917B050000118 , Adaptor Plate Part No-Eea0026883 , Stud Part No-907A020000017 , Hex Nut Part No-369-0110 , Flat Washer Part No-Maw10ga , Drive Line Part No-917B050000092 , Spider Assy. - 6C Part No-907A050000050 , Spring Washer Part No-Mdw10sa , Hex Head Bolt Part No-370-0310 , Spacer Part No-912A060000178 , Wheel Assy. Part No-907B070000067 , Wheel Rim Part No-917B050000009 , Sleek Tyre 17.5 X R25 Part No-907A050000091 , Valve, Wheel Rim Part No-907A050000075 , Steering Hydraulic Group Part No-907B070000029 , Feeder Unit Block Part No-19Wl050000019 , Accumulator Part No-12Wl050000999 , Relief Valve Assy. Part No-625B050000064 , Relief Cartridge Part No-Eea0008997 , Seal Kit-Relief Valve, ( * ) Marked Items Part No-Eea0009001 , Accumulator ( 4-Ltr ) Part No-811A050000191 , Seal Kit For ( * ) Marked Items Part No-Eea0019109 , Sealing Ring Part No-Eea0022384 , O-Ring Part No-Eea0022385 , Pilot Valve Part No-910B050000055 , 2 Way Poppet Valve ( Nc ) Part No-907A050000001 , Gasket Part No-912A050000229 , Accumulator Charge Valve Part No-912B050000309 , Repair Kit Part No-Eea0018821 , Suction Flange Part No-917A020000061 , Suction Flange Part No-917A020000062 , Feeder Block Mounting Bracket Part No-917A020000068 , Check Valve Part No-907A050000004 , Steering Contrl Valve Part No-917B050000115 , Hydraulic Pump ( Steering And Brake ) Part No-917B050000017 , M14 Screw Part No-Eea0026292 , M14 Nut Part No-Eea0026293 , Oil Seal Part No-Eea0011535 , Thr. Plate Part No-Eea0026294 , Seal. Chann Part No-Eea0026295 , Seal. Bk-Up Part No-Eea0026296 , Seal Sect. Part No-Eea0026297 , Plug Part No-Eea0022648 , Seal Kit Part No-Eea0026838 , Split Flange Half ( Code 61 ) Part No-D10a010000032 , Special Fitting Part No-907A050000067 , Manifold Part No-907B020000051 , Bracket, Acc. Charge Vlv Part No-912A020000652 , Pipe Bend ( 90 Degree ) Part No-917A050000058 , Clamp Part No-Eea0019155 , Hose Clip Part No-P105phb , O Ring Part No-S2712 , O Ring Part No-S2803 , O Ring 32.92X3.53-N-Nbr90 Part No-341-5030 , Hose Assy. Part No-907A050000065 , Hose Assy. Part No-907A050000066 , Hyd.Hose Part No-Stdb025 / 004 , Hyd.Hose Part No-625A050000113 , Hose Assy. Part No-Stdd026 / 039 , Hose Assy. Part No-Stdd026 / 084 , Hose Assy. Part No-Stdd026 / 112 , Hose Assy. Part No-Stdd026 / 301 , Hose Assy. Part No-Stdd026 / 309 , Hose Assy. Part No-Stdd026 / 310 , Hose Assy. Part No-Stdd026 / 317 , Hose Assy. Part No-Stdd026 / 321 , Hose Assy. Part No-Stdd026 / 323 , Hose Assy. Part No-Stdd026 / 327 , Hose Assy. Part No-Stdd026 / 334 , Hose Assy. Part No-Stdd033 / 033 , Hose Assy. Part No-Stdd033 / 037 , Hose Assy. Part No-Stdd033 / 094 , Hex Bushing Part No-Bp8bb7 , Bonded Seal Part No-Sc011 / 009 , Bonded Seal Part No-Sc011 / 013 , Bonded Seal Part No-Sc011 / 016 , Bonded Seal Part No-Sc011 / 019 , Bonded Seal Part No-Sc011 / 024 , Bonded Seal Part No-Sc011 / 027 , Straight Adaptor Part No-Se024 / 201 , Straight Adaptor Part No-Se024 / 202 , Straight Adaptor Part No-Se024 / 203 , Straight Adaptor Part No-Se024 / 208 , Straight Adaptor Part No-Se024 / 209 , Straight Adaptor Part No-Se024 / 211 , Straight Adaptor Part No-Se024 / 212 , Straight Adaptor Part No-Se024 / 217 , Straight Adaptor Part No-Se024 / 218 , Straight Adaptor Part No-Se024 / 219 , Straight Adaptor Part No-Se024 / 429 , Straight Adaptor Part No-Se024 / 430 , Swivel Adaptor ( F / F ) Part No-Se024 / 431 , Adaptor Part No-Se024 / 454 , Tee Part No-Vu10f10e01ds , Swivel Nut Elbow Part No-Vu10f10e21bs , Elbow 45 Deg Part No-Vu10f10e21cs , Reducer Part No-Vu10f16e16as , St. Adaptor Part No-Vu10f8e16as , St. Adaptor Part No-Vu12f12e16as , Swivel Elbow, 90 Deg. Part No-Vu12f12e21bs , Adaptor Part No-Vu12f12e33ds , Adaptor Part No-Vu12f16e16as , Elbow 90 Degree Part No-Vu16f16e20bs , Swivel Nut Elbow Part No-Vu16f16e21bs , Straight Adaptor Part No-Vu6f6e16as , Swivel Nut Elbow Part No-Vu6f6e21bs , Swivel, Tee Part No-Vu6f6e25ds , Swivel Nut Branch Tee Part No-Vu6f6e33ds , Elbow 90 Degree Part No-Vu6f8e20bs , Elbow 90 Degree Part No-Vu8f8e21bs , Hex Nut Part No-369-0106 , Hex Nut Part No-369-0110 , Hex Nut Part No-369-0112 , Hex Head Bolt Part No-370-0206 , Hex Head Bolt Part No-370-0237 , Hex Head Bolt Part No-370-0304 , Hex Head Bolt Part No-370-0306 , Hex Head Bolt Part No-370-0312 , Hex Head Bolt Part No-370-0402 , Hex Head Bolt Part No-370-0403 , Hex Socket Head Cap Screw Part No-370-2411 , Threaded Boss ( M12x15lg ) Part No-Eea0016795 , Flat Washer Part No-Maw06ga , Flat Washer Part No-Maw08ga , Flat Washer Part No-Maw10ga , Flat Washer Part No-Maw12ga , Spring Washer Part No-Mdw06sa , Spring Washer Part No-Mdw08sa , Spring Washer Part No-Mdw10sa , Spring Washer Part No-Mdw12sa , Hex Head Bolt Part No-T6gg12 , Hex Head Bolt Part No-T8gg28 , Spring Washer Part No-W8gf , Pressure Filter Part No-811A050000182 , Filter Element Part No-Eea0018438 , Filter Mounting Bracket Part No-917A020000087 , Hex Head Bolt Part No-370-0420 , Bracket, Pilot Valve Part No-910A020000187 , Bracket Part No-Eea0025607 , Plate Part No-Eea0025606 , Hex Nut Part No-Mt28mgg , Hose Assy. Part No-Stdd033 / 114 , Boss Part No-Eea0001567 , Service Hydraulic Group Part No-907B070000030 , Manifold Block Part No-910A050000019 , Check Valve Part No-Eea0030269 , Seal Kit, Check Valve Part No-Eea0030272 , Direction Valve Part No-Eea0030270 , Seal Kit, Direction Valve Part No-Eea0030273 , Solenoid Valve Part No-Eea0030271 , Seal Kit, Solenoid Valve Part No-Eea0030274 , 3 / 2 Way Valve Part No-19Wl050000655 , Check Valve Part No-625A050000111 , Gasket Part No-912A050000229 , Hydraulic Hand Pump Part No-611B050000326 , Hydraulic Pump ( Steering And Brake ) Part No-917B050000017 , M14 Screw Part No-Eea0026292 , M14 Nut Part No-Eea0026293 , Oil Seal Part No-Eea0011535 , Thr. Plate Part No-Eea0026294 , Seal. Chann Part No-Eea0026295 , Seal. Bk-Up Part No-Eea0026296 , Seal Sect. Part No-Eea0026297 , Plug Part No-Eea0022648 , Seal Kit Part No-Eea0026838 , Relief Valve Assy. Part No-625B050000064 , Relief Cartridge Part No-Eea0008997 , Seal Kit-Relief Valve, ( * ) Marked Items Part No-Eea0009001 , Return Filter Part No-611A050000018 , Filter Element Part No-Eea0003479 , Container Part No-Eea0000029 , O Ring ( * ) Part No-Eea0000031 , O Ring ( * ) Part No-Eea0000032 , O Ring ( * ) Part No-Eea0000033 , Hex Socket Head Cap Screw Part No-370-2409 , Sealkit, ( * ) Marked Items Part No-Eea0001034 , Service Control Vale Part No-907B050000089 , T-Bolt Clamp Part No-12Wl050000817 , Suction Flange Part No-917A020000064 , Suction Flange Part No-917A020000063 , Stand Pipe Part No-803A000000337 , Split Flange Half ( Code 61 ) Part No-D10a010000032 , Quick Release Coupling Part No-625A050000011 , Bspp Socket Part No-625A050000106 , Bspp Plug Part No-625A050000107 , Plug For Qrc Part No-625A060000008 , Pipe Bend ( 90 Degree ) Part No-917A050000058 , Manifold Part No-907B020000051 , Hose Clip Part No-P105phb , Flanged Pipe Part No-Eea0025628 , Elbow Part No-D06a050000150 , O Ring 32.92X3.53-N-Nbr90 Part No-341-5030 , O Ring Part No-S2816 , O Ring Part No-S2803 , Hose Assy. Part No-917A050000068 , Hose Assy. Part No-Stdd026 / 039 , Hose Assy. Part No-Stdd026 / 289 , Hose Assy. Part No-Stdd026 / 295 , Hose Assy. Part No-Stdd026 / 301 , Hose Assy. Part No-Stdd026 / 310 , Hose Assy. Part No-Stdd026 / 315 , Hose Assy. Part No-Stdd026 / 380 , Hose Assy. Part No-Stdd032 / 030 , Hose Assy. Part No-Stdd032 / 042 , Hose Assy. Part No-Stdd032 / 047 , Hose Assy. Part No-Stdd033 / 014 , Hose Assy. Part No-Stdd033 / 106 , Hyd. Hose Part No-Stdb025 / 013 , Hyd.Hose ( 51 Mm ) Part No-625A050000113 , Hyd. Hose Part No-Stdb025 / 014 , Hyd.Hose ( 51 Mm ) Part No-625A050000113 , Hyd.Hose Part No-Stdb025 / 004 , Hyd.Hose ( 51 Mm ) Part No-625A050000113 , Hydraulic Hose Part No-19Wl050000562 , Adaptor Part No-D06a050000132 , Adaptor Part No-Vu12f12e33ds , Adaptor Part No-Vu12f16e16as , Adaptor Part No-Vu16f16e16asb , Adaptor Part No-Vu8f8e21cs , Adaptor ( Unf To Jic ) Part No-Vu20f20e20asa , Elbow 45 Deg. Part No-Vu12f12e21cs , Elbow 90 Degree Part No-Vu8f8e21bs , Elbow, 90 Degree M / F Part No-Se012 / 022B , Elbow, 90 Degree M / F Part No-Se012 / 026 , Elbow, Std.90 Degree F / F Part No-Bp8bl , Gauge Adaptor Part No-Eea0003750 , Reducer, M / M Part No-Se012 / 096 , Reducer, M / M Part No-Se012 / 097 , Special Elbow Part No-Eea0028571 , Special Elbow Part No-Eea0017326 , St. Adaptor Part No-Se024 / 081 , St.Swivel Adaptor M / F Part No-Se012 / 062 , Straight Adaptor Part No-Se024 / 201 , Straight Adaptor Part No-Se024 / 202 , Straight Adaptor Part No-Se024 / 203 , Straight Adaptor Part No-Se024 / 206 , Straight Adaptor Part No-Se024 / 208 , Straight Adaptor Part No-Se024 / 209 , Straight Adaptor Part No-Se024 / 211 , Straight Adaptor Part No-Se024 / 217 , Straight Adaptor Part No-Se024 / 427 , Straight Adaptor Part No-Vu6f6e16as , Straight Adaptor M / M Part No-Se024 / 207 , Straight Adaptor, M / M Part No-Se012 / 085 , Swivel Adaptor ( F / F ) Part No-Se024 / 431 , Swivel Elbow, 90 Deg. Part No-Vu12f12e21bs , Swivel Nut Branch Tee Part No-Vu6f6e33ds , Swivel Nut Elbow Part No-Vu16f16e21bs , Swivel Nut Elbow Part No-Vu6f6e21bs , Swivel, Tee Part No-Vu6f6e25ds , Bonded Seal Part No-Sc011 / 009 , Bonded Seal Part No-Sc011 / 016 , Bonded Seal Part No-Sc011 / 019 , Bonded Seal Part No-Sc011 / 024 , Bonded Seal Part No-Sc011 / 027 , Flat Washer Part No-Maw12ga , Hex Bushing Part No-Bp9bb8 , Hex Head Bolt Part No-370-0308 , Hex Head Bolt Part No-370-0312 , Hex Head Bolt Part No-370-0402 , Hex Head Bolt Part No-370-0405 , Hex Head Bolt Part No-370-0420 , Hex Head Bolt Part No-370-0607 , Hex Head Bolt Part No-T8gg28 , Hex Head Plug ( Bsp ) Part No-Sc036 / 002 , Hex Head Plug ( Bsp ) Part No-Sc036 / 004 , Hex Nut Part No-369-0110 , Hex Socket Head Cap Screw Part No-370-2411 , Hex. Head Plug ( 1-5 / 8Unf-2A ) Part No-Sc036 / 056 , Spring Washer Part No-Mdw10sa , Spring Washer Part No-Mdw12sa , Spring Washer Part No-Mdw16sa , Spring Washer Part No-W8gf , Hose Sleeve Part No-611A050000139 , Hex Head Bolt Part No-370-0306 , Flat Washer Part No-Maw10ga , Manifold Block Part No-910B050000054 , Pressure Filter Part No-811A050000182 , Filter Element Part No-Eea0018438 , Filter Mounting Bracket Part No-917A020000087 , Hose Assy. Part No-Stdd033 / 114 , Hex Head Bolt Part No-370-0304 , Boss Part No-Eea0001567 , Hose Assy. Part No-Stdd033 / 037 , Hose Assy. Part No-Stdd026 / 024 , Hose Assy. Part No-Stdd033 / 024 , Hose Assembly Part No-623D02584 / 182 , Hose Assembly Part No-623D02584 / 201 , Hose Assy. Part No-Stdd026 / 323 , Hose Assy. Part No-Stdd026 / 092 , Hose Assy. Part No-Stdd026 / 047 , Hose Assy. Part No-Stdd026 / 317 , Hose Assy. Part No-Stdd026 / 328 , Hose Assembly Part No-623D02584 / 753 , Hose Assembly Part No-623D02584 / 756 , Speical Fitting Part No-Eea0029310 , Threaded Boss Part No-Eea0027253 , Swivel Elbow, 90 Deg. Part No-Vu12f12e21bs , Reducer, M / M Part No-Se012 / 095 , Bonded Seal Part No-Sc011 / 013 , Hex Head Plug ( Bsp ) Part No-Sc036 / 003 , Threaded Boss ( M12x15lg ) Part No-Eea0016795 , Straight Adaptor Part No-Se024 / 219 , Swivel Nut Elbow Part No-Vu10f10e21bs , Hose Assy. Part No-907A050000065 , Straight Adaptor Part No-Vu10f10e01as , St. Adaptor Part No-Se024 / 210 , Straight Adaptor Part No-Se024 / 430 , St.Swivel Adaptor M / F Part No-Se012 / 066 , Reducer, M / M Part No-Se012 / 101 , Straight Adaptor Part No-Se024 / 212 , Hose Assy. Part No-Stdd026 / 314 , Hose Assy. Part No-Stdd026 / 025 , Hose Assy Part No-Stdd033 / 023 , Hose Assy. Part No-Stdd033 / 039 , Hose Assy. Part No-Stdd033 / 031 , Special Fitting Part No-Eea0029315 , Hydraulic Pump Part No-910B050000063 , Hydraulic Pump, Brake Oil Part No-907B050000025 , Screw Part No-Eea0027587 , Washer Part No-Eea0027588 , Seal Part No-Eea0027589 , Standard Seal Part No-Eea0027590 , Shaft Seal Part No-Eea0027591 , Ring Part No-Eea0027592 , Anti Extrusion Part No-Eea0027593 , Dowel Pin Part No-Eea0027594 , Seal Kit Part No-Eea0029260 , Pressure Filter Part No-811A050000182 , Filter Element Part No-Eea0018438 , Relief Valve Assy. Part No-625B050000064b , Relief Cartridge Part No-Eea0008997 , Seal Kit-Relief Valve, ( * ) Marked Items Part No-Eea0009001 , Valve, Check 50 Psi Crack Part No-117439 , Accumulator ( 4-Ltr ) Part No-811A050000191 , Seal Kit For ( * ) Marked Items Part No-Eea0019109 , Sealing Ring Part No-Eea0022384 , O-Ring Part No-Eea0022385 , Brake Valve Part No-917B050000013 , Repair Kit, Brake Valve Part No-Eea0025375 , 3 Way Dcv Part No-811A050000158 , 3 / 2 Way Valve Part No-19Wl050000655 , Gasket Part No-907A050000047 , Gasket Part No-912A050000229 , Suction Flanged Part No-910A020000228 , Stand Pipe Part No-625A060000092 , Stand Pipe ( 1 1 / 4 Bspt ) Part No-621A000000202 , Special Elbow Part No-Eea0012523 , Elbow, 90 Degree M / F Part No-Se012 / 024 , Half Coupling Part No-Bp2fka , Special Elbow Part No-912A020000477 , Return Manifold Part No-822B020000066 , Half Coupling Part No-Bp7fka , Half Coupling Part No-Bp8fka , Coupling Part No-Stdd017 / 014 , Coupling Part No-Stdd017 / 015 , Quick Release Coupling Part No-912A050000201 , Plug Part No-912A060000188 , Manifold Block Part No-917B060000025 , Manifold Block Part No-917B060000021 , Gauge Panel Assy. Part No-907A070000028 , Bracket For Gauge Isolator Part No-907B020000064 , Pres.Gauge Isolator Valve Part No-811A050000013 , Drive Oil Pressure Gauge Part No-813B000000182 , Oil Pressure Gauge Part No-917B050000080 , Hex Nut Part No-369-0110 , Hex Head Bolt Part No-Stdb035-10-25 , Spring Washer Part No-Mdw10sa , Hex Socket Head Cap Screw Part No-370-2141 , Hex Nut Part No-369-0105 , Spring Washer Part No-Mdw05sa , Gauge Adaptor Part No-811A060000088 , St.Swivel Adaptor M / F Part No-Se012 / 062 , Filter Mounting Bracket Part No-917A020000087 , Bulkhead Bar Weldment Part No-917A020000072 , Plate Part No-Eea0025411 , Tee Adaptor Part No-105635 , Tee Adaptor Part No-102273 , O Ring Part No-S3308 , Clamp Part No-Eea0019155 , Gauge Adaptor Part No-Eea0009296 , Hose Assembly Part No-623D02584 / 333 , Hose Part No-625A00397 / 026 , Hyd.Hose ( 38 Mm ) Part No-Eea0009461 , Hose Clamp Part No-P9phb , Hose Assy. Part No-Stdd026 / 010 , Hose Assy. Part No-Stdd026 / 019 , Hose Assy. Part No-Stdd026 / 024 , Hose Assy. Part No-Stdd026 / 031 , Hose Assy. Part No-Stdd026 / 034 , Hose Assy. Part No-Stdd026 / 035 , Hose Assy. Part No-Stdd026 / 045 , Hose Assy. Part No-Stdd026 / 047 , Hose Assy. Part No-Stdd026 / 051 , Hose Assy. Part No-Stdd026 / 065 , Hose Assy. Part No-Stdd026 / 085 , Hose Assy. Part No-Stdd026 / 092 , Hose Assy. Part No-Stdd026 / 108 , Hose Assy. Part No-Stdd026 / 123 , Hose Assy. Part No-Stdd026 / 182 , Hose Assy. Part No-Stdd026 / 190 , Hose Assy. Part No-Stdd026 / 283 , Hose Assy. Part No-Stdd026 / 285 , Hose Assy. Part No-Stdd026 / 295 , Hose Assy. Part No-Stdd026 / 301 , Hose Assy. Part No-Stdd026 / 309 , Hose Assy. Part No-Stdd026 / 314 , Hose Assy. Part No-Stdd026 / 315 , Hose Assy. Part No-Stdd026 / 317 , Hose Assy. Part No-Stdd026 / 328 , Hose Assy. Part No-Stdd026 / 335 , Hose Assy. Part No-Stdd033 / 014 , Hose Assy. Part No-Stdd033 / 041 , Hoseassy. Part No-Stdd033 / 047 , Adaptor Part No-907A050000039 , St. Adaptor ( Metric To Jic ) Part No-917A050000060 , St. Adaptor ( Metric To Jic ) Part No-917A050000061 , St. Adaptor ( Metric To Jic ) Part No-917A050000062 , Fitting Part No-Eea0004895 , Bonded Seal Part No-Sc011 / 009 , Bonded Seal Part No-Sc011 / 016 , Bonded Seal Part No-Sc011 / 019 , Bonded Seal Part No-Sc011 / 024 , Bonded Seal Part No-Sc011 / 027 , Elbow, 90 Degree M / F Part No-Se012 / 024 , Elbow, 90 Degree M / F Part No-Se012 / 026 , St.Swivel Adst.Swivel Adaptor F / F Part No-Se012 / 044 , St.Swivel Adst.Swivel Adaptor F / F Part No-Se012 / 046 , St.Swivel Adaptor M / F Part No-Se012 / 066 , St.Swivel Adaptor M / F Part No-Se012 / 067 , Straight Adaptor, M / M Part No-Se012 / 082 , Straight Adaptor, M / M Part No-Se012 / 085 , Straight Adaptor, M / M Part No-Se012 / 086 , Reducer, M / M Part No-Se012 / 100 , Reducer, M / M Part No-Se012 / 101 , St. Adaptor Part No-Se024 / 008 , St. Adaptor Part No-Se024 / 009 , St. Adaptor Part No-Se024 / 078 , Straight Adaptor Part No-Se024 / 201 , Straight Adaptor Part No-Se024 / 202 , Straight Adaptor Part No-Se024 / 203 , Straight Adaptor Part No-Se024 / 208 , Straight Adaptor Part No-Se024 / 211 , Straight Adaptor Part No-Se024 / 214 , Straight Adaptor Part No-Se024 / 217 , Straight Adaptor Part No-Se024 / 218 , Straight Adaptor Part No-Se024 / 219 , Straight Adaptor Part No-Se024 / 220 , Straight Adaptor Part No-Se024 / 287 , Tee, M / M / F Part No-Se024 / 330 , Straight Adaptor Part No-Vu10f10e16as , Swivel Tee, 7 / 8 Part No-Vu10f10e20ds , Swivel Nut Elbow Part No-Vu10f10e21bs , St. Adaptor Part No-Vu10f8e16as , St. Adaptor Part No-Vu12f12e16as , Swivel Elbow, 90 Deg. Part No-Vu12f12e21bs , Adaptor Part No-Vu12f12e33ds , Adaptor Part No-Vu12f16e16as , Swivel Nut Elbow Part No-Vu6f6e21bs , Swivel Nut Elbow Part No-Vu6f6e21cs , Swivel, Tee Part No-Vu6f6e25ds , Swivel Nut Branch Tee Part No-Vu6f6e33ds , Straight Adaptor Part No-Vu8f12e02as , Fitting Part No-Vu8f12e02bs , Hyd Fitting Part No-Vu8f12e16as , Hyd Fitting Part No-Vu8f8e16as , Elbow 90 Degree Part No-Vu8f8e21bs , Adaptor Part No-Vu8f8e21cs , Swivel Tee, 3 / 4 Part No-Vu8f8e26ds , Hex Nut Part No-369-0112 , Bolt Hex M6x35 8.8 Zyp 5-8 M Part No-370-0212 , Hex Head Bolt Part No-370-0240 , Hex Head Bolt Part No-370-0304 , Hex Head Bolt Part No-370-0306 , Hex Head Bolt Part No-370-0310 , Hex Head Bolt Part No-370-0404 , Hex Head Bolt Part No-370-0405 , Hex Socket Head Cap Screw Part No-370-2338 , Hex Socket Head Cap Screw Part No-370-2411 , Flat Washer Part No-Maw08ga , Flat Washer Part No-Maw10ga , Flat Washer Part No-Maw12ga , Spring Washer Part No-Mdw06sa , Spring Washer Part No-Mdw08sa , Spring Washer Part No-Mdw10sa , Spring Washer Part No-Mdw12sa , Hex Head Plug ( Bsp ) Part No-Sc036 / 002 , Hex. Head Plug ( 1-1 / 16Unf-2A ) Part No-Sc036 / 054 , Sp. Elbow Part No-Eea0027448 , Pipe Manifold Part No-907A020000056 , Coupling Part No-Stdd017 / 012 , Coupling Part No-Stdd017 / 013 , Coupling Part No-Stdd017 / 014 , Hex Head Plug ( Bsp ) Part No-Sc036 / 001 , Hex Head Plug ( Bsp ) Part No-Sc036 / 006 , Hex Head Plug ( Bsp ) Part No-Sc036 / 008 , O Ring Part No-S3306 , O Ring Part No-S3310n , O Ring Part No-S3312n , O Ring Part No-S3316n , O Ring Part No-S3320 , Flow Control Valve Part No-R2c050000101 , O Ring Part No-S2803 , Hex Head Bolt Part No-Stdb035-12-30 , Flanged Adaptor Part No-910A020000227 , Straight Adaptor Part No-Se024 / 201 , O Ring Part No-S2722 , Hex Head Bolt Part No-Stdb035-10-30 , Manifold Block Part No-910B050000054 , Straight Adaptor Part No-Se024 / 221 , Special Fitting Part No-Eea0029644 , Hose Assy. Part No-Stdd026 / 084 , Bonded Seal Part No-Sc011 / 013 , Straight Adaptor Part No-Se024 / 222 , Straight Adaptor Part No-Se024 / 430 , Straight Adaptor M / M Part No-Se024 / 207 , Straight Adaptor Part No-Se024 / 209 , Straight Adaptor Part No-Se024 / 212 , Banjo Adaptor Assy. M / M Part No-Se012 / 144 , St. Adaptor Part No-Se024 / 079 , Swivel Nut Elbow Part No-Vu16f16e21bs , Hose Assy. Part No-Stdd033 / 031 , Hose Assy. Part No-Stdd033 / 110 , Hose Assy. Part No-Stdd026 / 152 , Hose Assy. Part No-Stdd026 / 104 , Hex Head Bolt Part No-Stdb035-10-25 , Threaded Boss ( M10x15lg ) Part No-Eea0016870 , Hose Assy. Part No-Stdd026 / 110 , Transmission Hydraulic Group Part No-907B070000032 , Bracket For Trans. Filter Part No-917A020000075 , Flange Elbow Part No-917A050000046 , Adapter Male / Female - Jic Part No-D06a050000050 , Gauge Adaptor Part No-Eea0009296 , Sp. Fitting Part No-Eea0026859 , Hose Assy. Part No-Stdd026 / 306 , Hose Assy. Part No-Stdd033 / 055 , Hose Assy. Part No-Stdd033 / 060 , Hose Assy. Part No-Stdd033 / 062 , St. Adaptor Part No-Vu12f12e16as , Swivel Elbow, 90 Deg. Part No-Vu12f12e21bs , Elbow 45 Deg. Part No-Vu12f12e21cs , Straight Adaptor Part No-Vu6f2e02as , Swivel Nut Elbow Part No-Vu6f6e21bs , Hex Head Bolt Part No-370-0402 , Spring Washer Part No-Mdw12sa , Bonded Seal Part No-Sc011 / 024 , Straight Adaptor Part No-Se024 / 208 , Hex Head Bolt Part No-T6gg16 , Hex Head Bolt Part No-T8gg26 , Hex Socket Head Cap Screw Part No-T8gh28 , Spring Washer Part No-W6gf , Spring Washer Part No-W8gf , Hyd. Oil Cooler Part No-917B050000120 , Hydraulic Cooler Matrix ( 40Kw ) Part No-Eea0027901 , Transmission Cooler Matrix ( 70Kw ) Part No-Eea0027902 , Brake Cooler Matrix ( 15Kw ) Part No-Eea0027903 , Fan House-Em Part No-Eea0027904 , Fan-580 / 7 / S38zl / 38 / Pag / 74.75 Part No-Eea0027905 , Motor Bracket-Em Part No-Eea0027906 , Hydraulic Motor Part No-Eea0027907 , Seal Kit For Hyd. Motor Part No-Eea0028875 , Ring, Snap Part No-Eea0028876 , Lip Seal Part No-Eea0028877 , Spacer Part No-907A020000070 , Hex Head Bolt Part No-370-0328 , Flat Washer Part No-W6ga , Spring Washer Part No-Mdw10sa , Hex Head Bolt Part No-370-0306 , Spring Washer Part No-Mdw12sa , Hyd. Oil Cooler Mtg. Bracket Part No-907B020000069 , Hex Head Bolt Part No-370-0240 , Spring Washer Part No-Mdw08sa , Hex Head Bolt Part No-370-0244 , Hex Head Bolt Part No-370-0405 , Flat Washer Part No-W5ga , Front Control Panel Group Part No-907B070000054 , Front Control Panel Box Assy Part No-907B040000006 , Hex Head Bolt Part No-370-0237 , Hex Head Bolt Part No-370-0306 , Hex Head Bolt Part No-370-0412 , Mounting Plate Part No-917A020000078 , Front Panel Box Part No-917B020000057 , Clamp Part No-Eea0007778 , Front Control Panel Part No-907B050000087 , Rubber Sheet Part No-Eea0025389 , Flat Washer Part No-Maw10ga , Flat Washer Part No-Maw12ga , Spring Washer Part No-Mdw08sa , Spring Washer Part No-Mdw10sa , Spring Washer Part No-Mdw12sa , 7 Display Part No-910B040000044 , Connector Kit ( Pv780 ) Part No-910A040000045 , Starting Switch Part No-19Wl040000073 , Emergency Stop Push Button Part No-Eea0022291 , Emergency Stop Marker Part No-Eea0029991 , Relay Module Part No-Epra040000007 , Buzzer 24V Dc Part No-19Wl040000084 , On Delay Timer ( Crouzet ) Part No-910A040000059 , Terminals Part No-Eea0022453 , Terminal Block ( Black ) Part No-Eea0029389 , Terminal End Plate Part No-Eea0022455 , End Clamps Part No-Eea0021276 , Terminal Block Part No-Eea0028566 , Terminal Block ( Kut10, Yellow ) Part No-Eea0029453 , Terminal Block ( Kut10, Green ) Part No-Eea0029454 , End Plate Part No-Eea0028567 , Mounting Rail Part No-Eea0021275 , Rect.Fork Type Terminal Part No-912A040000095 , Cable End Sleeve Terminal ( 2.5 Sq.Mm ) Part No-Eea0030029 , Cable End Sleeve Terminal ( 1.5 Sq.Mm ) Part No-Eea0030028 , Cable End Sleeve Terminal ( 6 Sq.Mm ) Part No-Eea0030117 , Plate Part No-Eea0029723 , Slotted Pan Head Screw Part No-Mt05eb16g , Hex. Nut Part No-Mt05lgg , Rubber Sheet Part No-Eea0026924 , Rubber Sheet Part No-Eea0026925 , Plate Part No-Eea0028469 , Threaded Boss Part No-811A060000056 , Hex Head Bolt Part No-370-0205 , Spring Washer Part No-Mdw06sa , Slotted Button Head Screw Part No-370-5113 , Flat Washer Part No-Maw06ga , S.C Cable Gland ( 3 / 4Et ) Part No-Eea0029761 , S.C Cable Gland ( 3 / 4Et ) Part No-Eea0030009 , S.C Cable Gland ( 1Et ) Part No-Eea0029760 , Cable Gland Pvc Hood ( 3 / 4 Et ) Part No-Eea0029992 , Cable Gland Pvc Hood ( 1 Et ) Part No-Eea0029993 , Contact Block ( No ) Part No-Eea0027986 , Side Control Panel Box Assy Part No-907B040000008 , Hex Head Bolt Part No-370-0238 , Hex Head Bolt Part No-370-0314B , Side Control Panel Box Part No-917B020000056 , Mounting Rail Part No-Eea0021275 , Flat Washer Part No-Maw08ga , Flat Washer Part No-Maw10ga , Spring Washer Part No-Mdw08sa , Spring Washer Part No-Mdw10sa , Rubber Sheet Part No-Eea0025422 , Hex Head Bolt Part No-370-0308 , Slotted Pan Head Screw Part No-Mt05eb16g , Hex Head Bolt Part No-370-0205 , Spring Washer Part No-Mdw06sa , Flat Washer Part No-Maw06ga , Hex Nut Part No-369-0106 , Hex Nut Part No-369-0110 , Side Control Panel Part No-907B050000099 , Push Button - 3 Position Part No-116602 , Selector Switch Part No-Epra040000001 , Selector Switch ( 3 Pos. ) Part No-910A040000014 , Mecan1905 Part No-907B040000001 , Relay - 24 Volt Part No-116600 , Relay Module Part No-Epra040000007 , Timer Part No-Eea0020754 , Dc / Dc Convertor Part No-907A040000030 , Circuit Breaker, 32A Part No-Eea0024825 , Circuit Breaker, 6A Part No-19Wl871050265 , Circuit Breaker, 10A Part No-19Wl871050023 , Circuit Breaker, 16A Part No-Eea0025390 , Mcb Link ( 10 Way ) Part No-907A040000004 , Multi-Level Terminal Part No-Eea0029579 , End Plate Part No-Eea0029611 , Terminal Block ( Black ) Part No-Eea0029389 , Terminal End Plate Part No-Eea0022455 , End Clamps Part No-Eea0021276 , Terminal Block Part No-Eea0028566 , Terminal Block ( Kut10, Yellow ) Part No-Eea0029453 , Terminal Block ( Kut10, Green ) Part No-Eea0029454 , End Plate Part No-Eea0028567 , Mounting Din Rail Part No-Eea0022456 , Marker ( 15 ) Part No-910A040000026 , S.C Cable Gland ( 3 / 4Et ) Part No-Eea0029761 , S.C Cable Gland ( 3 / 4Et ) Part No-Eea0030009 , S.C Cable Gland ( 1Et ) Part No-Eea0029760 , Cable Gland Pvc Hood ( 3 / 4 Et ) Part No-Eea0029992 , Cable Gland Pvc Hood ( 1 Et ) Part No-Eea0029993 , Positive Lock Female Terminal Part No-Eea0025631 , Diode Terminal Block Part No-Eea0028499 , Diode Block End Plate Part No-Eea0029314 , Rect.Fork Type Terminal Part No-912A040000095 , Diode Circuit Part No-12Wl040000213 , Threaded Boss Part No-811A060000056 , Hex Head Bolt Part No-370-0205 , Flat Washer Part No-Maw06ga , Spring Washer Part No-Mdw06sa , Slotted Pan Head Screw Part No-Mt05eb16g , Hex Nut Part No-369-0106 , Cable Duct Part No-Eea0030113 , Sleeve, Flexib ( Bend ) Spireal Cut Part No-912A040000144 , Cable End Sleeve Terminal ( 2.5 Sq.Mm ) Part No-Eea0030029 , Cable End Sleeve Terminal ( 1.5 Sq.Mm ) Part No-Eea0030028 , Cable End Sleeve Terminal ( 6 Sq.Mm ) Part No-Eea0030117 , Male Connector Housing ( 12 Way ) Part No-Eea0028690 , Male Wedge Lock ( 12 Way ) Part No-Eea0028698 , Female Connector Housing ( 12 Way ) Part No-Eea0028694 , Female Wedge Lock ( 12 Way ) Part No-Eea0028702 , Male Connector Housing ( 6 Way ) Part No-Eea0028688 , Male Wedge Lock ( 6 Way ) Part No-Eea0028696 , Female Connector Housing ( 6 Way ) Part No-Eea0028692 , Female Wedge Lock ( 6 Way ) Part No-Eea0028700 , Socket For Dt Plug Part No-Eea0027064 , Pin For Dt Receptacle Part No-Eea0027062 , Terminating Resistor Link Part No-Eea0026749 , Cross Connection Link Assy Part No-Stda038 / 05 , Marker ( 0-100 ) Part No-910A040000024 , Marker ( 30 ) Part No-910A040000025 , Flexible Wire, 1.5 Sq.Mm, Pink Part No-Eea0025274 , Flexible Wire, 1.5 Sq.Mm, Blue Part No-Eea0025275 , Flexible Wire, 1.5 Sq.Mm, Yellow Part No-Eea0025276 , Flexible Wire, 1.5 Sq.Mm, Green Part No-Eea0025277 , Flexible Wire, 1.5 Sq.Mm, Violet Part No-Eea0025278 , Flexible Wire, 1.5 Sq.Mm, Red Part No-Eea0025279 , Flexible Wire, 1.5 Sq.Mm, Grey Part No-Eea0025280 , Flexible Wire, 1.5 Sq.Mm, White Part No-Eea0025281 , Flexible Wire, 1.5 Sq.Mm, Black Part No-Eea0025282 , Flexible Wire, 2.5 Sq.Mm, Red Part No-Eea0025283 , Flexible Wire, 6 Sq.Mm, Red Part No-Eea0025285 , Adjustable Cable Clamp Part No-912A040000170 , Heat Sleeve ( 5Mm ) Part No-Eea0027285 , Ring Tongue Terminal Part No-625A040000148 , By-127 Diode For P.B.Station Part No-Eea0002174 , Rubber Sheet Part No-Eea0026927 , Rubber Sheet Part No-Eea0026928 , Straight Wire Butt Connector Part No-Epra040000014 , Gland Plate Part No-Eea0030650 , Duel Head Lamp Relay ( 24V ) Part No-Eea0030031 , 6 Pole Female Connector Part No-12Wl040000181 , Terminal Part No-Eea0026062 , Hex. Nut Part No-Mt05lgg , Female Connector Housing ( 2 Way ) Part No-Eea0028691 , Female Wedge Lock ( 2 Way ) Part No-Eea0028699 , Male Connector Housing ( 2 Way ) Part No-Eea0028687 , Male Wedge Lock ( 2 Way ) Part No-Eea0028695 , Multicore Control Cable ( 4X1.5 ) Part No-907A040000025 , Hose Sleeve Part No-907A050000072 , On Delay Timer ( Crouzet ) Part No-910A040000059 , Twin Cable End Sleeve Terminal ( 1.5 Sq.Mm ) Part No-Eea0030690 , Led Work Light, 45W, Low Beam Part No-917A040000021 , Led Work Light, 45W, Wide Flood Part No-917A040000022 , Led Beacon Part No-917A040000024 , Led Flashing Light ( Amber ) Part No-917A040000023 , Led Tail Light Part No-907A040000018 , Led Work Light ( 15W ) Part No-Ssla040000019 , Paired Horn Part No-919A002910934 , Hyd. Oil Temp Sensor Part No-917A040000006 , Bracket Temp Prob. Mnt. Part No-912A060000126 , Side Mnt. Level Switch ( N Part No-912C040000105 , Gasket Part No-627B000000121 , Hyd. Oil Filter Clogging Indicator Part No-917A040000007 , Capacitance Oil Level Switch ( Falling ) Part No-917A040000026 , Fuel Sensor ( 907 ) Part No-907B040000013 , Brake Oil Temp. Switch Part No-917A040000005 , Pressure Transmitter, 250 Bar Part No-910A040000001 , Wireless Camera Recording System Part No-917B040000025 , Wireless Camera Part No-910A040000034 , Wireless Camera Display Part No-910A040000056 , Reversing Alarm Part No-Eea0022223 , Emergency Stop Control Station Part No-Eea0028455 , Emergency Stop Marker Part No-Eea0029991 , Interior Light Part No-910A040000029 , 2 Pole Amp Connector Part No-Eea0025257 , 3 Pole Delphi Packard Connector Part No-Eea0025258 , Female Terminal-Metri Pack 150 Part No-Eea0026863 , Apc 312 Harness With Connector Part No-910A040000002 , Rd120 Harness Cum Connector Part No-Eea0025260 , Multicore Control Cable ( 2X1.5 ) Part No-907A040000024 , Multicore Control Cable ( 4X1.5 ) Part No-907A040000025 , Multicore Control Cable ( 7X2.5 ) Part No-907A040000022 , Multicore Control Cable ( 18X2.5 ) Part No-907A040000023 , Multicore Control Cable For Rc Part No-912A040000157 , Can Bus Cable Part No-907A040000012 , 6 Pole Female Sealed Connector ( Dtm Series ) Part No-Eea0028818 , Female Connector Housing ( 2 Way ) Part No-Eea0028691 , Female Wedge Lock ( 2 Way ) Part No-Eea0028699 , Male Connector Housing ( 2 Way ) Part No-Eea0028687 , Male Wedge Lock ( 2 Way ) Part No-Eea0028695 , Female Connector Housing ( 6 Way ) Part No-Eea0028692 , Female Wedge Lock ( 6 Way ) Part No-Eea0028700 , Male Connector Housing ( 6 Way ) Part No-Eea0028688 , Male Wedge Lock ( 6 Way ) Part No-Eea0028696 , Pin For Dt Receptacle Part No-Eea0027062 , Socket For Dt Plug Part No-Eea0027064 , Junction Box Part No-907B040000026 , Local Control Station Part No-907B040000029 , Cable Gland Pvc Hood ( 3 / 4 Et ) Part No-Eea0029992 , Cable Gland Pvc Hood ( 1 Et ) Part No-Eea0029993 , Cable End Sleeve Terminal ( 2.5 Sq.Mm ) Part No-Eea0030029 , Cable End Sleeve Terminal ( 1.5 Sq.Mm ) Part No-Eea0030028 , Positive Lock Female Terminal Part No-Eea0025631 , Cross Connection Link Assy Part No-Stda038 / 05 , Cross Connection Link Assy Part No-Stda038 / 03 , Cross Connection Link Assy Part No-Stda038 / 02 , Mounting Din Rail Part No-Eea0022456 , Multi-Level Terminal Part No-Eea0029579 , End Clamps Part No-Eea0021276 , Terminal End Plate Part No-Eea0022455 , Terminal Block ( Black ) Part No-Eea0029389 , Partition Plate Without Foot Part No-Eea0030102 , Battery, 12V Part No-12Wl040000162 , Battery Cut-Off Switch ( Lockable ) Part No-910A040000033 , Battery Switch Bracket Part No-910A020000116 , Battery Cable Assy. Pos. To Sw. Part No-907B040000038 , Battery Cable Assy Part No-910A040000017 , Battery Cable Assy. Sw. To Starter Part No-907B040000039 , Battery Cable Assy. Neg To Ground Part No-907B040000040 , Battery Cable Assy Part No-910A040000020 , Rubber Pad Part No-Eea0027280 , Rubber Pad Part No-Eea0027279 , Rubber Pad Part No-Eea0027278 , Airfilter Extension Cable Part No-Eea0027658 , Solenoid Connector ( Led ) Part No-Eea0029713 , Pg Cable Gland Pg13.5 Part No-Eea0028456 , Limit Switch Part No-910A040000022 , Plate Part No-Eea0029957 , Cable Gland ( 1 / 2 Npt ) Part No-Eea0029456 , Roof Light Mtg. Bracket Part No-907A020000019 , Beacon Mtg. Bkt. Part No-910A020000114 , Light Mounting Bracket Part No-Eea0029720 , Guard Part No-Eea0014429 , Sleeve ( 10 Mm Dia ) Part No-19Wl040000061 , Sleeve ( 20 Mm Dia. ) Part No-19Wl040000062 , Cable Tie 3.6Mm X150mm Black Part No-12Wl040000035 , Cable Tie 4.8Mm X 200 Mm Black Part No-12Wl040000040 , Cab Lock Cable Ties Part No-811A050000033 , Clamp Part No-Eea0028574 , Clamp Part No-Eea0007779 , Clamp Part No-Eea0007778 , Hose Support Clamp Part No-Stda037 / 32 , Hose Support Clamp Part No-Stda037 / 40 , Hose Support Clamp Part No-Stda037 / 76 , Threaded Boss Part No-811A020000105 , Threaded Boss Part No-811A060000056 , Socket Head Cap Screw M5x35 L Part No-370-2146 , Slotted Button Head Screw Part No-370-5113 , Hex Socket Head Cap Screw Part No-370-2171 , Hex Socket Head Cap Screw Part No-Mt05nh16 , Slotted Button Head Screw Part No-370-5122 , Hex. Head Screw Part No-Mt05lg16g , Hex Head Bolt Part No-370-0304 , Hex Head Bolt Part No-370-0238 , Hex Head Bolt Part No-370-0404 , Hex Head Bolt Part No-370-0306 , Hex Head Bolt Part No-370-0237 , Hex Head Bolt Part No-370-0240 , Hex Head Bolt Part No-370-0204 , Hex Head Bolt Part No-370-0242 , Hex Head Bolt Part No-370-0142 , Hex Socket Head Cap Screw Part No-370-2170 , Hex Head Bolt Part No-370-0140 , Spring Washer Part No-Mdw05sa , Spring Washer Part No-Mdw06sa , Spring Washer Part No-Mdw08sa , Spring Washer Part No-Mdw10sa , Spring Washer Part No-Mdw12sa , Spring Washer Part No-Mdw04sa , Flat Washer Part No-Maw05gag , Flat Washer Part No-Maw06ga , Flat Washer Part No-Maw08ga , Flat Washer Part No-Maw10ga , Medium Washer Part No-Maw04gcg , Hex Nut Part No-369-0106 , Hex Nut Part No-369-0108 , Cable Tags ( 910 ) Part No-910B040000036 , Hose Sleeve Part No-907A050000072 , Hose Sleeve Part No-907A050000073 , Electronic Joystick ( 2 Axis ) Part No-917B040000013 , Deutsche 6 Pole Male Connector Part No-Eea0025246 , Deutsche 6 Pole Female Connector Part No-Eea0025247 , Controller Part No-910A040000046 , Connector Kit ( Iqan-Mc42 ) Part No-910A040000047 , Bracket Part No-917A020000051 , Bracket Part No-917A020000052 , Plate Part No-Eea0027696 , Hex Head Bolt Part No-370-0205 , Slotted Button Head Screw Part No-370-5114 , Hex Nut Part No-369-0103 , Hex Head Bolt Part No-370-0308 , Hex Nut Part No-369-0110 , Hex Socket Head Cap Screw Part No-370-2141 , Battery Guard Part No-907A020000052 , Flashing Led, Red Part No-912A040000216 , Rubber Pad Part No-Eea0029908 , Yellow Sticker Kit Part No-910B040000037 , Bracket Part No-Eea0031308 , Flange Pipe Weldment Part No-907B020000103 , Expansion Bellow Part No-907B050000096 , Flange Pipe Weldment Part No-907B020000100 , Silencer Weldment Assy. Part No-907B020000009 , Flane Top Part No-Eea0027144 , Catalytic Converter With Muffler Part No-917B050000121 , Flane Bottom Part No-Eea0027145 , Flange Pipe Weldment Part No-907B020000082 , Bracket, Exhaust Part No-907B020000008 , Gasket For Exhaust Part No-907A050000011 , Gasket Part No-907A050000085 , Threaded Boss Part No-Eea0027140 , Hex Head Bolt Part No-370-0611 , Flat Washer Part No-Maw16ga , Spring Washer Part No-Mdw16sa , Flat Washer Part No-W6ga , Flat Washer Part No-W5ga , Hex Head Bolt Part No-370-0244 , Hex Head Bolt Part No-370-0250 , Hex Nut Part No-369-0108 , Hex Head Bolt Part No-370-0308 , Spring Washer Part No-Mdw10sa , Hex Nut Part No-369-0110 , Spring Washer Part No-Mdw08sa , Hex Head Bolt Part No-370-0312 , Fume Diluter Group Part No-907B070000072 , Mounting Plate, Fume Diluter Part No-907B020000104 , Flange Pipe Weldment Part No-907B020000105 , Clamp Part No-912B020000419 , Exhaust Gas Diluter Part No-912B050000318 , Gasket Part No-Eea0028557 , Hex Nut Part No-369-0112 , Flat Washer Part No-Maw12ga , Spring Washer Part No-Mdw12sa , Spring Washer Part No-Mdw16sa , Hex Head Bolt Part No-Stdb035-12-40 , Hex Head Bolt Part No-Stdb035-16-30 , Hex Head Bolt Part No-T7gg20 , Spring Washer. Part No-W7gf , Fibre Glass Tape Part No-910A050000031 , Fiber Glass Wool Part No-907A050000045 , Galvanise Wire Part No-Eea0027482 , Heat Insulation Jacket Part No-907A050000100 , Cooler Guard Part No-907B020000106 , Grill Part No-907B070000075 , Flat Washer Part No-Maw08ga , Spring Washer Part No-Mdw08sa , Hex Nut Part No-369-0108 , Hex Head Bolt Part No-370-0248 , Hex Head Bolt Part No-370-0250 , Support Bracket Part No-907B020000037 , Support Bracket Part No-907A020000038 , Support Bracket Part No-907A020000039 , Support Bracket Part No-907A020000107 , Support Bracket Part No-907A020000108 , Support Bracket Part No-907A020000119 , Support Bracket Part No-917A020000021 , Cover Part No-907A020000004 , Cover, Air Intake Part No-907A020000057 , Cover Part No-907A020000109 , Cover Part No-907A020000110 , Guard Plate Part No-907A020000114 , Guard Plate Part No-907A020000115 , Plate Part No-907A020000116 , Cover Part No-907B020000036 , Cover Part No-907B020000111 , Cover Part No-907B020000112 , Cover Part No-907B020000113 , Cover Part No-917A020000038 , Cover Part No-917A020000039 , Clamp Part No-Eea0007778b , Flat Washer Part No-Maw12ga , Cover Part No-917A020000041 , Cover Part No-917A020000042 , Exhaust Cover Assy. Part No-907B070000074 , Exhaust Cover Part No-907A020000117 , Exhaust Cover Part No-907A020000118 , Cover Plate Part No-Eea0033191 , Cover Plate Part No-Eeb0033187 , Plate Part No-Eea0033188 , Plate Part No-Eea0033189 , Threaded Boss ( M10x15lg ) Part No-Eea0016870 , Hex Head Bolt Part No-370-0206 , Hex Head Bolt Part No-370-0240 , Hex Head Bolt Part No-370-0304 , Flat Washer Part No-Maw06ga , Flat Washer Part No-Maw08ga , Spring Washer Part No-Mdw06sa , Spring Washer Part No-Mdw08sa , Spring Washer Part No-Mdw10sa , Stopper Part No-917A020000040 , Hand Rest Seat Part No-907A050000069 , Hex Nut Part No-369-0108 , Avm Part No-907A050000092 , Threaded Boss Part No-Eea0003462 , Flat Washer Part No-Maw10ga , Flat Washer Part No-Maw12ga , Flat Washer Part No-Maw16ga , Flat Washer Part No-Maw20ga , Spring Washer Part No-Mdw08sa , Spring Washer Part No-Mdw10sa , Spring Washer Part No-Mdw12sa , Spring Washer Part No-Mdw16sa , Spring Washer Part No-Mdw20sa , Hex Nut Part No-369-0110 , Hex Nut Part No-369-0112 , Hex Nut Part No-369-0116 , Hex Head Bolt Part No-370-0240 , Hex Head Bolt Part No-370-0306 , Hex Head Bolt Part No-370-0308 , Hex Head Bolt Part No-370-0310 , Hex Head Bolt Part No-370-0312 , Hex Head Bolt Part No-370-0316 , Hex Head Bolt Part No-370-0404 , Hex Head Bolt Part No-370-0406 , Hex Head Bolt Part No-370-0412 , Hex Head Bolt Part No-370-0606 , Hex Head Bolt Part No-370-0609 , Hex Head Bolt Part No-370-0613 , Hex Head Bolt Part No-370-0809 , Cover, Fuel Tank Part No-910A020000239 , Gasket Part No-910A050000068 , Hex Head Bolt Part No-Stdb035-12-30 , Battery Box Part No-907B020000125 , Cover, Battery Part No-910A020000213 , Clamp, Battery Part No-Eea0031720 , Flat Washer Part No-Maw10ga , Spring Washer Part No-Mdw10sa , Hex Head Bolt Part No-Stdb035-10-20 , Hex Head Bolt Part No-Stdb035-10-30 , Hex Nut Part No-369-0110 , Threaded Boss Part No-Eea0007149 , Hex Head Bolt Part No-370-0304 , Hex Head Bolt Part No-370-0403 , Cover Part No-811B020000150 , Gasket Part No-811B050000067 , Conveyor Assy. Part No-907A070000080 , Threaded Boss Part No-Eea0007149 , Spring Washer Part No-Mdw10sa , Hex Head Bolt Part No-370-0310 , Bracket Part No-907A070000081 , Bracket Part No-907B020000124 , Name Plate ( Fuel ) Part No-912A050000001 , Name Plate ( Hyd. Oil ) Part No-912A050000003 , Name Plate ( M / C Sr. No ) Part No-100618 , Warning Plate ( Do Not Stand Here ) Part No-016B000091012 , Name Plate, Model Part No-907A050000009 , Decal, Tire Pres. Part No-246918 , Name Plate, Pressure Reading Part No-907A050000077 , Name Plate, Caution Safety Link Part No-Xa1365 , Name Plate, Joy Stick Operation Part No-907A050000078 , Warning Plate - Caution Crush Hazard Part No-822A050000034 , Hydraulic Oil - Identification Plate Part No-822A050000035 , Lubrication Plate Part No-907A050000010 , Voltage Indicator Plate Part No-822A050000037 , Warning Plate Part No-917A050000040 , Warning Plate - Danger Area Part No-822A050000039 , Name Plate - Steering Operation Part No-822A050000040 , Name Plate - Operator Control Part No-822A050000041 , Brake Hyd. Oil Identification Plate Part No-917A050000044 , Warning Plate- Do Not Touch Part No-917A050000045 , Name Plate-Pressure Check Points Part No-917A050000083 , Name Plate, Emergency Steering Part No-907A050000076 , Name Plate, Air Filter Part No-907A050000058 , Name Plate, Park Brake Release Part No-907A050000059 , Name Plate, Engine Start Stop Part No-907A050000060 , Name Plate, Weld Instruction Part No-907A050000061 , Name Plate, Battery Switch Part No-907A050000062 , Air Intake Kit Part No-907B050000013 , Air Cleaner Assy Part No-Eea0027315 , Hose Part No-Eea0027316 , Hose Clamp, T Bolt Part No-Eea0027317 , Precleaner, Metal Part No-Eea0027318 , Bracket Mounting Assy Part No-Eea0027319 , Bracket Mounting, Powder Coated Part No-Eea0027320 , Rain Hood, Metal Part No-Eea0027321 , Hose Elbow Part No-Eea0027322 , Hose Clamp, T Bolt Part No-Eea0027323 , Pipe Assy, Powder Coated Part No-Eea0027324 , Hose Part No-Eea0027325 , Pipe Assy, Powder Coated Part No-Eea0027326 , Bracket Assy Part No-Eea0027327 , Restriction Indicator Part No-Eea0027328 , Hose Clamp T-Bolt Part No-Eea0029203 , Hose Reducer Part No-Eea0029205 , Bracket, Air Cleaner Part No-907A020000025 , Hex Head Bolt Part No-370-0304 , Hex Head Bolt Part No-370-0308 , Spring Washer Part No-Mdw10sa , Flat Washer Part No-Maw10ga , Hex Nut Part No-369-0110 , Adapter Part No-907A050000020 , Bracket, Air Filter Part No-Eea0027682 , Th. Boss Part No-Eea0027216 , Hex Head Bolt Part No-370-0310 , Filter Element, Primary Part No-Eea0027698 , Filter Element, Safety Part No-Eea0027699 , Tool Kit Part No-907A070000017 , Axle Oil Part No-12Wl050000144 , Lithium Base Grease Part No-Xa1417 , Fire Extinguisher Part No-625A050000110 , Drive Screw Part No-T1000 , Engine Oil Part No-907A050000006 , Fastner Sealant Part No-00Ea000001155 , Hydraulic Oil Part No-D10a050000093 , Brake Oil Part No-917A050000049 , Centralised Lubrication System ( Automatic ) Part No-917B050000022 , Engine Coolant Part No-907A050000007 , Front Reflector Part No-12Wl040000125 , Rear Reflector Part No-12Wl040000126 , Reflective Tape ( Red ) Part No-19Wl050000631 , Reflective Tape ( White ) Part No-19Wl050000630 , Reflective Tape ( Yellow ) Part No-19Wl050000632 , O Ring Kit Part No-917A050000113 , Automatic Fire Suprression System Part No-907A070000027 , Automatic Fire Detection & Supression System Part No-19Wl050000868 , Bracket ( Fire System ) Part No-19Wl020000733 , Threaded Boss Part No-811A020000105 , Hex Head Screw Part No-Mt08lg16g , Spring Washer Part No-Mdw08sag , Hex Nut Part No-Mt08lgg , Flat Washer Part No-Maw08gag , Accumulator Charging Kit Part No-811A050000124 , Hand Pump Part No-907A050000048 , Hand Pump Part No-917A050000106 , Single Core Wire Rubber Bidding Part No-D06a050000189 , Logo-Eimco Elecon ( Engine Hood ) Part No-12Wl050000047 , Wheel Choke Part No-910A050000034 , E.M Tyre Inflating & Checking Device Lb Part No-907A050000064 , Engine Cooler Group Part No-907B070000070 , Cac Cooler Assy. Part No-907B070000071 , Cac With Radiator Part No-907B050000094 , Cac Cooler Mtg. Bracket Part No-907B020000092 , Hex Head Bolt Part No-Stdb035-16-35 , Spring Washer Part No-Mdw16sa , Hex Head Bolt Part No-Stdb035-10-35 , Spring Washer Part No-Mdw10sa , Flat Washer Part No-Maw10gab , Cac Tube, Inlet Part No-907B020000093 , Cac Silicone Hose Part No-907A050000028 , T-Bolt Hose Clamp Part No-907A050000034 , Cac Tube, Outlet Part No-907B020000094 , Elbow, Cac Part No-910A050000074 , Radiator Tube, Inlet Part No-907B020000095 , Silicone Hose, Coolant Part No-907A050000029 , Silicone Hose, Coolant Part No-Eea0027283 , T-Bolt Hose Clamp Part No-907A050000032 , Silicone Hose, Coolant Part No-907A050000030 , Silicone Hose, Coolant Part No-Eea0027284 , T-Bolt Hose Clamp Part No-907A050000033 , Radiator Tube, Outlet Part No-907B020000096 , Elbow Hose, Coolant Part No-907A050000031 , Coolant Hose Part No-Eea0027289 / 006 , Hose Clamp Part No-P9phb , Coolant Hose Part No-Eea0027287 / 004 , Hose Clamp ( Fuel Circuit ) Part No-12Wl050000172 , Nipple Part No-907A020000024 , Bonded Seal Part No-Sc011 / 016 , Coolant Hose Part No-Eea0027287 / 001 , Coolant Hose Part No-Eea0027287 / 006 , Hex Head Plug ( Bsp ) Part No-Sc036 / 004 , Bonded Seal Part No-Sc011 / 024 , Hex Head Plug ( Bsp ) Part No-Sc036 / 008 , T-Bolt ( Hose-Clamp ) ( Heavey Duty ) Part No-19Wl050000052 , Hex Head Plug ( Bsp ) Part No-Sc036 / 002 , Bonded Seal Part No-Sc011 / 009 , Sponge ( Side ) Part No-12Wl050000123 , Rubber Sheet Part No-Eea0032933 , Ball Valve ( G 1 / 2 ) Part No-Rb2c050000137 , Hose Assembly Part No-623D02584 / 113 , St.Swivel Adaptor M / F Part No-Se012 / 064 , Straight Adaptor, M / M Part No-Se012 / 084 , Tank Mounting Bracket Part No-910B020000254 , Threaded Boss ( M12 ) Part No-Eea0002561 , Threaded Boss Part No-Eea0033008 , Hex Nut Part No-369-0110 , Hex Head Bolt Part No-370-0308 , Th. Boss Part No-Eea0027216 , Flat Washer Part No-Maw10ga , Elbow, Coolant Tube Part No-910B020000178 , Bush ( Metric ) Part No-Mbh100 / 116 / 50A , Bush, Metric Part No-Mbh100 / 116 / 70A , Bush ( Metric ) Part No-Mbh90 / 106 / 100A , Pin Part No-917A060000009 , Bush ( Metric ) Part No-Mbh90 / 106 / 60A , Pin Part No-917A060000015 , Pin Part No-917A060000012 , Spherical Bearing Part No-Stdc003 / 056 , Seal Part No-Seg251 , O Ring Part No-Seg1099 , Wear Washer Part No-912B060000117 , Counter Balance Valve Part No-Eea0027160 , Valve Seal Kit Part No-Eea0028796 , Counter Balance Valve Part No-Eea0027167 , Valve Seal Kit Part No-Eea0028811 , Spherical Bearing Part No-Eea0022799 , Avm, Engine Part No-910A050000025 , Avm, Engine Part No-19Wl050000865 , Spider Assembly ( 7C ) Part No-912A050000208 , Radial Seal Ringpart No-Eea0027541 , Radial Seal Ring Part No-Eea0027555 , Spider Assy. - 6C Part No-907A050000050 , Relief Valve Assy. Part No-625B050000064 , Pres.Gauge Isolator Valve Part No-811A050000013 , Drive Oil Pressure Gauge Part No-813B000000182 , Oil Pressure Gauge Part No-917B050000080 , Hydraulic Motor Part No-Eea0027907 , Fan Part No-Eea0027905 , Lip Seal Part No-Eea0028877 , Selector Switch ( 2 Pos. ) Part No-910A040000013 , Joystick Handle ( Walvoil ) Part No-12Wl040000189 , Temperature Sensor Part No-Eea0027843 , Sensor Part No-Eea0027837 , Sensor Part No-Eea0027819 , V-Ribbed Belt Part No-Eea0027827 , Accelerator Pedal Part No-Eea0027831 , Cab Control Part No-Eea0025805 , Transmission Temp. Sensor ( 917 ) Part No-Eea0026850 , Transmission Pressure Sensor ( 917 Part No-Eea0026851 , Hyd. Motor - Cr Part No-611B050000321 , Hose Assy. Part No-Stdd026 / 301 , Gauge Adaptor Part No-811A060000088 , Oil Filter Kit Part No-907A050000055 , Bonded Seal Part No-Sc011 / 006 , Fuel Filter Insert Part No-907A050000052 , Fuel Filter Part No-907A050000053 , Fuel Filter Insert Part No-907A050000054 , Minimess Coupling Part No-822A050000031 , Service Control Valve Part No-917B050000015 , Repair Kit ( Accumulator Charge Valve ) Part No-Eea0025349 , Twin Oil Cooler Part No-917B050000021 , Power Relay ( 24V ) Part No-19Wl040000115 , Base For Change Over Relay Part No-12Wl040000024 , Fuel Tank Cap With Neck Part No-907A050000068 , Suspension Tube Type-A Part No-Clsa020000034 , Cac With Radiator Part No-907B050000023 , Radiator Cooler Matrix ( 115Kw ) Part No-Eea0027908 , Seal Kit Part No-Eea0029259 , Transmission Control Unit ( Econ.A312 ) Part No-Eea0028730 , Tcu Harness ( Apc - 312 ) Part No-Eea0033374 , Cooler Fan, Sucker Part No-907B050000095 , Piston Part No- 201C000000054 Model-21 , Comp. Ring Part No- 201A000000072 Model-21 , Oil Ring Part No- 201A000000073 Model-21 , Connecting Rod Part No- 201E000000053 Model-21 , Retaining Ring Part No- 201A000000048 Model-21 , Bushing Part No- 201A000000049 Model-21 , Hex Head Bolt Part No- T8hg24 Model-21 , Crank Sleeve Part No- 201B000000759 Model-21 , Crank Shaft Part No- 201M000000087 Model-21 , Bearing Part No- G201 Model-21 , Vent Cap Assy Part No- 200M000000084 Model-21 , Valve And Housing Group Part No- 201M000000110 Model-21 , Valve Housing Cover Part No- 201B000000066 Model-21 , Valve Housing Gasket Part No- 201A000000065 Model-21 , Gasket For Motor Housing Part No- 021A000000196 Model-21 , Wrist Pin Assembly Part No- 201M000000086 Model-21 , Hex Head Bolt Part No- T8gg16 Model-21 , Cylinder Part No- 201C000000744 Model-21 , Cylinder Gasket Part No- 201A000000064 Model-21 , Gasket Set Part No- 201M000000637 Model-21 , Valve Housing Part No- 201M000000090 Model-21 , Gasket, Cover Part No- 021D000000182 Model-21 , Seal Part No- S1301 Model-21 , Shim Set Part No- Ga62a Model-21 , Axle Bearing Cap Part No- 021C000000181 Model-21 , Motor Pinion Part No- 021B000000198 Model-21 , Motor Pinion Spacer Part No- 021A000000197 Model-21 , Bearing Part No- G132 Model-21 , Motor Pinion Assy Part No- 021M000000114 Model-21 , Clutch Group Part No- 021M000003075 Model-21 , Clutch Shaft Assy Part No- 021M000003076 Model-21 , Bearing Part No- G135 Model-21 , Clucth Thrust Washer Part No- 021A000003082 Model-21 , Clucth Coller Assy Part No- 021M000000148 Model-21 , Clutch Jaw Part No- 021B000003081 Model-21 , Key Part No- Kwt Model-21 , Clutch Pinion Assy. Part No- 021M000003078 Model-21 , Clucth Gear Part No- 021C000003080 Model-21 , Clutch Rod Part No- 012A000000029 Model-21 , Spring Part No- Za63 Model-21 , Seal Rod Part No- 021A000000030 Model-21 , Shim Set Part No- Gb32a Model-21 , Lower Deck Intermediate G Part No- 021M000000115 Model-21 , Lower Deck Intermediate Part No- 021M000000116 Model-21 , L.D.Gear Part No- 021B000000016 Model-21 , Key Part No- Kwv Model-21 , L.D.Int.Pinion Part No- 021B000000035 Model-21 , Lower Deck Idler Group Part No- 021M000000117 Model-21 , Lower Deck Idler Shaft As Part No- 021M000000118 Model-21 , Bearing Part No- G140 Model-21 , Shaft-L.D.Gear Part No- 021B000000036 Model-21 , L.D.Idler Gear Part No- 021B000000017 Model-21 , Axle Gear Part No- 021B000000178 Model-21 , Key Part No- Kw36 Model-21 , Axle Guage - 610 Mm Part No- 021A000000211 Model-21 , King Bolt Type B Part No- 021M000000160 Model-21 , Centering Roller Group Part No- 021M000001708 Model-21 , Hex Nut, Slotted Part No- T16gv Model-21 , Roller Assy Part No- 024M000000819 Model-21 , Anchor Roller Centering Part No- 021B000001707 Model-21 , Ball Race, Ud Part No- 021C000000150 Model-21 , Balls Part No- Gr16 Model-21 , Ball Race, Ld Part No- 021C000000151 Model-21 , Ud Gr Housing Covr Gasket Part No- 021C000000042 Model-21 , Upper Deck Idler Shaft Assy. Part No- 021M000000123 Model-21 , Upper Deck Idler Shaft Part No- 021A000000037 Model-21 , U.D.Idler Gear Part No- 021B000000018 Model-21 , Upper Deck Intermediate G Part No- 021M000000124 Model-21 , Upper Deck Inter. Shaft A Part No- 021M000000125 Model-21 , Gear Part No- 021B000000019 Model-21 , Woodruff Key Part No- Kw29 Model-21 , U.D.Int.Shaft & Pinion Part No- 021A000000038 Model-21 , Bearing Part No- G138 Model-21 , Chain Reel Group Part No- 021M000000126 Model-21 , Chain Reel Shaft Assy Part No- 021M000000127 Model-21 , Chain Reel Gear Part No- 021B000000020 Model-21 , Chain Reel Shaft Part No- 021B000000039 Model-21 , Key Part No- Kw34 Model-21 , Bearing Part No- G144 Model-21 , Bearing Part No- G145 Model-21 , Seal Part No- S265 Model-21 , Chain Reel Part No- 021C000000014 Model-21 , Chain Link Pin Part No- 012A000000041 Model-21 , Spring Washer Part No- W6gf Model-21 , Chain Roller Assy Part No- 021M000000132 Model-21 , Hex Nut Part No- T24gg Model-21 , Chain Roller Shaft Part No- 021B000000052 Model-21 , Roller, Bucket Chain Part No- 021A000000053 Model-21 , Lock Washer Part No- L49 Model-21 , Lock Nut Part No- L819 Model-21 , Bearing Part No- G121 Model-21 , Grease Nipple Part No- Bp1fg Model-21 , Linkage Pin Cen.Drum Levr Part No- 021A000000046 Model-21 , Bush, Centring Drum Linkage Part No- 021A000000045 Model-21 , Hex Nut Part No- T20gg Model-21 , Centering Drum Lever Part No- 021C000000043 Model-21 , Seal Part No- S219 Model-21 , Bearing Cup Part No- G510 Model-21 , Bearing Cone Part No- G511 Model-21 , Shim Set Part No- Gb80a Model-21 , Hex Head Bolt Part No- T10gg24 Model-21 , Centering Drum Cover Gasket Part No- 021A000000051 Model-21 , Hex Nut Part No- T18gg Model-21 , Spring Washer Part No- W18gf Model-21 , Thrust Stop Part No- 021B000000068 Model-21 , Bumper Spring Clamp Part No- 021A000000070 Model-21 , Bumper Spring Part No- 021A050000003 Model-21 , Spring Washer Part No- W8gf Model-21 , Hex Nut Part No- T8gg Model-21 , Hex Head Bolt Part No- T6gg32 Model-21 , Spring Part No- 012A000000085 Model-21 , Bucket Handle Part No- 012D000000084 Model-21 , Traction Valve Lever Part No- 012B000000093 Model-21 , Balance Spring Part No- 012A000000094 Model-21 , Spring Washer Part No- W5gf Model-21 , Hex Nut Part No- T5hg Model-21 , Hex Head Bolt Part No- T6gg24 Model-21 , Handle Assy Part No- 012M000000141 Model-21 , Traction Control Handle Part No- 012B000000096 Model-21 , Traction Handle Retainer Part No- 012B000000099 Model-21 , Traction Pivot Bushing Part No- 012A000000097 Model-21 , Shim Set Part No- Ga31a Model-21 , Pivot Handle Part No- 012A000000098 Model-21 , Traction Bonnet Group Part No- 012M000000140 Model-21 , Traction Valve Bonnet Part No- 012C000000090 Model-21 , Gasket Part No- Sga30 Model-21 , Valve Stem Part No- 012A000000088 Model-21 , Traction Valve Disc Part No- 012B000000086 Model-21 , Valve Disc Spring Part No- 012A000000081 Model-21 , Bucket Bonnet Group Part No- 021M000000139 Model-21 , Valve Stem Part No- 012A000000082 Model-21 , Bucket Valve Disc Part No- 012C000000079 Model-21 , Swivel Sleeve Assy Part No- 012M000000138 Model-21 , Air Screen Part No- 012A000000076 Model-21 , Swivel Gasket Part No- 012A000000077 Model-21 , Drain Cock Part No- Bp3rvd Model-21 , Gasket Part No- Sga36 Model-21 , Bonnet Part No- 021D000000080 Model-21 , Grease Nipple Part No- Bp1fg Model-21 , Hex Nut Part No- T8gg Model-21 , Traction Air Hose Assy Part No- 021M000000270 Model-21 , Hex Nut, Nyloc Part No- L211 Model-21 , Flat Washer Part No- W12ga Model-21 , Cable Spring Part No- 021A000000297 Model-21 , Rocker Arm Cable Long Part No- 021B000000290 Model-21 , Rocker Arm Cable Short Part No- 021B000000295 Model-21 , End Link Pin Part No- 021A000000040 Model-21 , Split Pin Part No- L119 Model-21 , End Link Part No- 021A000000057 Model-21 , Bucket Chain Assy Part No- 021M000000134 Model-21 , Chain Repair Kit Part No- 021M000000939 Model-21 , Bucket Bottom, Casting Part No- 021A030000011 Model-21 , Bucket Assy. ( Type48 ) Part No- 021M000002620 Model-21 , Air Motor Assy. Part No- 201M000000091 Model-21 , Piston Group Assy Part No- 201M000000085 Model-21 , Crank Shaft Group Part No- 201M000000088 Model-21 , Plain Crankshaft Assembly Part No- 201M000000760 Model-21 , Rotary Valve Assembly Part No- 201M000000089 Model-21 , Axle Cap ( 18-30 Ga. ) Part No- 021M000000253 Model-21 , L.D. Motor Pinion Part No- 150B060000001 Model-150 , Spacer Part No- 012A000000197 Model-150 , Bearing Part No- G130 Model-150 , L.D. Pinion Part No- 150B060000002 Model-150 , Bearing Part No- G132 Model-150 , Gear Part No- 021C000003080 Model-150 , Key Part No- Kw29 Model-150 , Gear Part No- 021B000000016 Model-150 , Bearing Part No- G135 Model-150 , Gear Part No- 150B060000005 Model-150 , Axle Cap Part No- 021C000000181 Model-150 , Shim Set Part No- Ga62a Model-150 , Seal Part No- S1301 Model-150 , Hub Part No- 150C060000009 Model-150 , Wheel Tyre Assy. Part No- 150M100000004 Model-150 , Key Part No- K12r66 Model-150 , Drain Cock Part No- Bp2rve Model-150 , Hex Head Bolt Part No- T10gg24 Model-150 , Washer Part No- W10gf Model-150 , Key Part No- Kwt Model-150 , Bolt Part No- T8gsk8 Model-150 , Bolt Part No- T10gg28 Model-150 , Axle Nut Part No- 021A000000185 Model-150 , Washer Part No- 021A000000184 Model-150 , Wheel Stud Part No- 802A000000708 Model-150 , Wheel Nut Part No- 802A000000709 Model-150 , Wheel Nut Part No- L262t Model-150 , Gasket Part No- 012A000000196 Model-150 , Washer Part No- W6gf Model-150 , Cap Screw Part No- T6gg28 Model-150 , Cap Screw Part No- T6gg24 Model-150 , Gasket Part No- 200A000000065 Model-150 , Valve Housing Cover Part No- 200A000000066 Model-150 , Cap Screw Part No- T6gg64 Model-150 , Cap Screw Part No- T6gg14 Model-150 , Gasket Part No- 200A000000064 Model-150 , Cylinder Part No- 200C000000050 Model-150 , Washer Part No- 200A000000099 Model-150 , Cap Screw Part No- T7gg16 Model-150 , Wrist Pin Part No- 200M000000086 Model-150 , Oil Ring Part No- 200A000000073 Model-150 , Comp. Ring Part No- 200A000000072 Model-150 , Piston Part No- 200C000000054 Model-150 , Connecting Rod Part No- 200D000000053 Model-150 , Connecting Rod Bushing Part No- 200A000000049 Model-150 , Retainer Ring Part No- 200A000000048 Model-150 , Bearing Part No- G200 Model-150 , Valve Housing Assy Part No- 200M000000090 Model-150 , Rotary Valve Assy Part No- 200M000000089 Model-150 , Air Motor Part No- 270M000000006 Model-150 , Bearing Part No- G107 Model-150 , Bush Part No- 150A060000011 Model-150 , U D Idler Gear Part No- 012B000000018 Model-150 , Pinionpart No- 012A000000038 Model-150 , U D Intetmediate Gear Part No- 012B000000019 Model-150 , Chain Reel Shaft Part No- 012B000000039 Model-150 , Bearing Part No- G138 Model-150 , Chain Reel Gear Part No- 012B000000020 Model-150 , Bearing Part No- G142 Model-150 , Chain Reel Part No- 150C030000001 Model-150 , Seal Part No- S197 Model-150 , Chain Link Pin Part No- 012A000000041 Model-150 , Gasket Part No- 012B000000042 Model-150 , Shim Set Part No- Ga16ax Model-150 , Chain Roller Shaft Part No- 630B000000081 Model-150 , Roller Part No- 630C000000083 Model-150 , Chain Assy. Part No- 021M000000133 Model-150 , End Link Pin Part No- 021A000000040 Model-150 , Cotter Pin Part No- L119 Model-150 , End Link Part No- 021A000000057 Model-150 , Spring Part No- 012A000000069 Model-150 , Bolt Part No- T6gg16 Model-150 , Bolt Part No- T8gg24 Model-150 , Washer Part No- W8gf Model-150 , Bolt Part No- T10gg20 Model-150 , Bolt Part No- T12gg48 Model-150 , Bolt Part No- T12gg20 Model-150 , Washer Part No- W12gf Model-150 , Washer Part No- W20gf Model-150 , Cap Screw Part No- T8gg20 Model-150 , Gasket Part No- Sga32a Model-150 , Seal Part No- S2300 Model-150 , Cap Screw Part No- T6ggw16 Model-150 , Cap Screw Part No- T6gg20 Model-150 , Bearing Part No- G280 Model-150 , Crank Shaft Part No- 200M000000517 Model-150 , Rotary Valve Part No- 270D000000002 Model-150 , Valve Housing Part No- 270D000000003 Model-150 , Bearing Part No- G2003 Model-150 , Bearing Part No- G2004 Model-150 , Bucket Part No- 150E020000094 Model-150 , Bucket Lip Part No- Eea0004865 Model-150 , Seal Part No- S300 Model-150 , Bush Part No- Ibh48 / 56 / 48A Model-150 , Cap Screw Part No- T8gh24 Model-150 , Nut Part No- T10gg Model-150 , Flat Washer Part No- W24gab Model-150 , Connecting Link Part No- 150B020000022 Model-150 , Bolt Part No- T4gg8 Model-150 , Locking Plate Part No- Sc009 / 003 Model-150 , Locking Plate Part No- Sc009 / 002 Model-150 , Pin Part No- 150A060000016 Model-150 , Spring Bush Part No- Ibh24 / 32 / 16A Model-150 , Nut Part No- T8gg Model-150 , Pin Part No- 150A060000015 Model-150 , Bolt Part No- T4gg16 Model-150 , Lock Washer Part No- W4gf Model-150 , Bolt Part No- T12gg28 Model-150 , Nut Part No- T12gg Model-150 , Pneumatic Cyl. Part No- 150B050000043 Model-150 , Pin Part No- 150A060000014 Model-150 , Seal Kit ( Suitable For # 150M10000005 ) Part No- Eea0000690 Model-150 , Nipple Part No- Bp8fna Model-150 , Union Elbow Part No- Bp8bsl Model-150 , Adaptor Part No- Se012 / 085 Model-150 , Manifold Part No- 150B020000028 Model-150 , Elbow Part No- Se012 / 026 Model-150 , Adaptor Part No- Se012 / 086 Model-150 , Adaptor Part No- Se012 / 007 Model-150 , Elbow Part No- Bp6bl Model-150 , Pipe Part No- Bp6fn28 Model-150 , Elbow Part No- Bp6bl Model-150 , Pipe Part No- Bp6fn40 Model-150 , Hose Assy Part No- 623D02584 / 230 Model-150 , Adaptor Part No- Se012 / 006 Model-150 , Adaptor Part No- Se012 / 097 Model-150 , Elbow Part No- Se012 / 027 Model-150 , Hose Assy Part No- 623D02584 / 238 Model-150 , Hose Assy Part No- 623D02584 / 242 Model-150 , Allen Bolt Part No- 370-2235 Model-150 , Washer Part No- Mdw08sa Model-150 , Nut Part No- 369-0108 Model-150 , Bolt Part No- 370-0264 Model-150 , Adaptor Part No- Se012 / 046 Model-150 , Adaptor Part No- Se012 / 066 Model-150 , Union Part No- Bp6bs Model-150 , Hose Clip Part No- P9phb Model-150 , Pn.Control Valve ( 1 / 2Bsp ) Part No- Eeb0010031 Model-150 , Gear Part No- 150C060000019 Model-150 , Side Ring Part No- 802B060000003 Model-150 , Locking Ring Part No- 802B060000002 Model-150 , Seal Part No- S115 Model-150 , Motor Pinion Part No- 150B060000018 Model-150 , Retaining Ring Part No- L1118 Model-150 , Circlip Part No- L1166 Model-150 , Gasket Part No- Sga24a Model-150 , Gasket Part No- 150B050000024 Model-150 , Gasket Part No- 150B050000025 Model-150 , Motor Pinion Part No- 150B060000031 Model-150 , Spacer Part No- 150A060000032 Model-150 , Shaft Part No- 150A060000035 Model-150 , Pinion Part No- 150B060000033 Model-150 , Bearing Part No- 150A050000029 Model-150 , Gear Part No- 150B060000034 Model-150 , Key Part No- Mk64r40 Model-150 , Key Part No- Mk75r56 Model-150 , Shim Set Part No- 150A050000026 Model-150 , Pinion Part No- 150B060000037 Model-150 , Gear Part No- 150B060000038 Model-150 , Shaft Part No- 150A060000040 Model-150 , Bearing Housing Part No- 150B060000036 Model-150 , Gear Part No- 150B060000041 Model-150 , Axle Part No- 150C060000043 Model-150 , Gear Part No- 150B060000044 Model-150 , Spacer Part No- 150A060000042 Model-150 , Bearing Part No- 150A050000030 Model-150 , Seal Part No- Seg242 Model-150 , Shim Set Part No- 150A050000027 Model-150 , Hub Part No- 150C060000054 Model-150 , Wheel Rim Assy Part No- 150D050000021 Model-150 , Tube Part No- 802A050000002 Model-150 , Flap Part No- 802A050000003 Model-150 , Bkt.Chain Roller Part No- 021A000000053 Model-150 , Pin Part No- 150B060000060 Model-150 , Spacer Part No- 150A060000062 Model-150 , Bearing Part No- G121 Model-150 , Gasket Part No- 150B050000023 Model-150 , Motor Pinion Part No- 150B060000047 Model-150 , Spacer Part No- 150A060000061 Model-150 , Seal Part No- Seg170 Model-150 , Shaft Part No- 150A060000049 Model-150 , Gear Part No- 150B060000048 Model-150 , Pinion Part No- 150B060000051 Model-150 , Key Part No- Mk60r45 Model-150 , Gear Part No- 150B060000050 Model-150 , Chain Reel Shaft Part No- 150B060000053 Model-150 , Seal Part No- Seg203 Model-150 , Gear Part No- 150B060000052 Model-150 , Key Part No- Mk66r63 Model-150 , Bumper Spring Part No- 150A050000022 Model-150 , Cylinder Part No- 150B020000108 Model-150 , Pin Part No- 150A060000056 Model-150 , Lock Plate Part No- 150A020000112 Model-150 , Keeper Plate Part No- Lka24a Model-150 , Bearing Part No- 150A050000028 Model-150 , Circlip Part No- 912A050000006 Model-150 , Pin Part No- 150B060000058 Model-150 , Spacer Part No- 150A060000057 Model-150 , Chain Assy Part No- 150B070000021 Model-150 , Bumper Spring Clamp Part No- 021A000000070 Model-150 , Pin Part No- Mkd25a66 Model-150 , Bush Part No- Ibh32 / 40 / 32A Model-150 , Spacer Part No- 150A020000047 Model-150 , Spring Part No- 824A000000277 Model-150 , Spacer Part No- Gsa8d Model-150 , Gasket Part No- 824B000000215 Model-150 , Bush Part No- Sd001 / 014 Model-150 , Link Part No- 623A000003189 Model-150 , Link Part No- 623A000003190 Model-150 , Pin Part No- 623A000003191 Model-150 , Pin Part No- 623A000003856 Model-150 , Hose Assy Part No- Stdd018 / 108 Model-150 , Hose Assy Part No- Stdd018 / 223 Model-150 , Hose Assy Part No- Stdd018 / 226 Model-150 , Hose Assy Part No- Stdd018 / 246 Model-150 , Hose Assy Part No- Stdd018 / 250 Model-150 , Wheel Stud Part No- 150A060000064 Model-150 , Wheel Nut Part No- 150A060000065 Model-150 , Lock Nut Part No- 803B000000488 Model-150 , Collar Assy Part No- 00Eb000000037 Model-150 , Arm ( L H ) Part No- 150D020000099 Model-150 , Arm ( R H ) Part No- 150D020000100 Model-150 , Lock Nut Part No- L274 Model-150 , Pn.Control Valve ( 1 / 2Bsp ) Part No- Eeb0010031 Model-150 , Motor Pinion Part No- 150B060000039 Model-150 , Cover, Lower Deck Gear Bo Part No- 150B020000113 Model-150 New , Cover, L.D.Gear Box Part No- 150B020000114 Model-150 New , Bearing Housing Part No- 150B060000046 Model-150 New , Bearing Housing Part No- 150B060000045 Model-150 New , Air Motor Arrangement Part No- 270M100000004 Model-150 New , Valve Housing Group Part No- 270M000000194 Model-150 New , Complete Crankshaft Group Part No- 200M000000530 Model-150 New , Piston Group Part No- 200M000000085 Model-150 New , Motor Housing Assembly Part No- 270M000000007 Model-150 New , Crank Sleeve Part No- 200B000000047 Model-150 New , Upper Deck Part No- 150D020000102 Model-150 New , Upper Deck Gear Box Part No- 150D020000101 Model-150 New , Gear Box Part No- 150D020000098 Model-150 New , Hopper Assy Part No- 150B070000074 Model-150 New , Hopper Support Bracket Part No- 150D020000110 Model-150 New , Upper Deck Gbox Assy. Part No- 150M100000055 Model-150 New , Guard, Upper Deck Part No- 150B020000049 Model-150 New , Hopper-Lh Part No- 150B020000136 Model-150 New , Hopper-Rh Part No- 150B020000137 Model-150 New , Hopper Door Part No- 150B020000134 Model-150 New , Side Plate, Rh Part No- 150B020000052 Model-150 New , Side Plate, Lh Part No- 150B020000053 Model-150 New , Shaft Part No- 803B000000004 Model-824 , Gear ( Model 824 ) Part No- 803B000000182 Model-824 , Key Part No- K58r40 Model-824 , Motor Pinion Spacer Part No- 021A000000197 Model-824 , Tab Washer Part No- 803A000000441 Model-824 , Gear Part No- 803B000000183 Model-824 , Bearing Part No- G140 Model-824 , Shaft Part No- 803B000000007 Model-824 , Gear Part No- 803B000000008 Model-824 , Bearing Part No- G142 Model-824 , Key Part No- K60r40 Model-824 , Gear Part No- 803B000000010 Model-824 , Bearing Part No- G144 Model-824 , Shaft Part No- 803B000000011 Model-824 , Gasket Part No- 803A000000223 Model-824 , Bearing Part No- G138 Model-824 , Key Part No- K12r66 Model-824 , Hex Socket Set Screw Part No- T10gs12 Model-824 , Shaft Assy Part No- 803M000000304 Model-824 , Bearing Part No- G146 Model-824 , Bearing Part No- 803A000000019 Model-824 , Bearing Cup Part No- G484 Model-824 , Bearing [ Cone ] Part No- 803A000000022 Model-824 , Key Part No- K64r58 Model-824 , Gear Part No- 803B000000012 Model-824 , Bearing Part No- G427 Model-824 , Bearing Cup Part No- G444 Model-824 , Oil Seal Part No- 803A000000020 Model-824 , Gasket Part No- 803D000000003 Model-824 , Shim Set Part No- 803B000000016 Model-824 , Plug Part No- 1027A050000003 Model-824 , Axle Cap Part No- 00Eb000000094 Model-824 , Gear Box Cover Part No- 00Ec000000131 Model-824 , Key Part No- K60r36 Model-824 , Spacer Part No- 803A000000124 Model-824 , Sealing Plate Part No- 803B000000015 Model-824 , Square Head Plug Part No- P9bp Model-824 , Dowel Pin Part No- 012A000001102 Model-824 , Spacer Part No- 803A000000121 Model-824 , Spacer Part No- 803A000000122 Model-824 , Spacer Part No- 803A000000123 Model-824 , Washer Part No- 621A000000074 Model-824 , Hex Nut, Nyloc Part No- L274 Model-824 , Lock Nut Part No- 803B000000488 Model-824 , Wheel Stud Part No- 802A000000708 Model-824 , Hex Nut, Nyloc Part No- L262t Model-824 , Wheel Nut Part No- 802A000000709 Model-824 , Upper Deck Assy. Part No- 824M000000324 Model-824 , Slotted Bolt ( A Size ) Part No- 824B000000415 Model-824 , Wedge Part No- 824B000000416 Model-824 , Spring Washer Part No- W10gf Model-824 , Hex Nut Part No- T10gg Model-824 , Hex Nut, Slotted Part No- T24gk Model-824 , Cotter Pin Part No- L153 Model-824 , Stud Part No- 00Ea000000122 Model-824 , Side Sheet-Lh Part No- 824C000000327 Model-824 , Side Sheet-Rh Part No- 824C000000328 Model-824 , Bumper Bar Assy. Part No- 824M000000113 Model-824 , Hex Nut Part No- T14gg Model-824 , Spring Washer Part No- W14gf Model-824 , Lock Plate For Model 824 Part No- 00Ea000000168 Model-824 , Taper Wedge Part No- 00Ea000000158 Model-824 , Spring Washer Part No- W16gf Model-824 , Gear Box Assy.-Bucket Drive Part No- 824M000000334 Model-824 , Upper Chain Roller Assy Part No- 824M000000193 Model-824 , First Intermediate Pinion Part No- 630B000000247 Model-824 , Gear Chain Reel Bucket Drive Part No- 630C000000248 Model-824 , Bearing Cartridge Part No- 630B000000272 Model-824 , Brg.Cartridge Chain Reel Shaft Part No- 630C000000274 Model-824 , 1St Int.Brg.Cartridge Part No- 630B000000275 Model-824 , Gasket, Motor Pinion Cap Part No- 630A000000290 Model-824 , Gasket, Bucket Drive Cover Part No- 630C000000292 Model-824 , Chain Reel Part No- 004C000000169 Model-824 , Chain End Pin Lock Part No- 004A000000182 Model-824 , Intermediate Gear Part No- 824C000000041 Model-824 , Chain Roller Assy Part No- 021M000000132 Model-824 , Bearing Part No- G204 Model-824 , Bucket Drive Hsg.Cover Plate Part No- 824E000000420 Model-824 , Motor Pinion Bucket Drive Part No- 824B000000040 Model-824 , Bearing Part No- G448 Model-824 , Bearing Cone Part No- G449 Model-824 , Bearing Part No- G546 Model-824 , Bearing Part No- G547 Model-824 , Bearing Part No- G548 Model-824 , Bearing Part No- G549 Model-824 , Bearing Part No- G562 Model-824 , Bearing Part No- G563 Model-824 , Brass Shim Set Part No- G1214 Model-824 , Shim Set Part No- G1215 Model-824 , Shim Set Part No- G1227 Model-824 , Seal Part No- S300 Model-824 , Key Part No- K10e60 Model-824 , Key Part No- K12e58 Model-824 , Key Part No- K8r34 Model-824 , Hex Head Bolt Part No- T8ggw20 Model-824 , Hex Head Bolt Part No- T8ggw16 Model-824 , Inter.Gear For Buc.Drive Part No- 630C000000245 Model-824 , 2Nd Int.Pinion Bucket Drive Part No- 630C000000249 Model-824 , Bearing Cone Part No- G533 Model-824 , Bearing Cup Part No- G534 Model-824 , Bearing Cone Part No- G531 Model-824 , Bearing Cup Part No- G532 Model-824 , Key Part No- K12e28 Model-824 , Chain Real Shaft Part No- 630C000000258 Model-824 , Square Head Plug Part No- Bp2bp Model-824 , Pipe Plug Part No- Bp6bp Model-824 , Plug, Csk Square Part No- Bp5bpa Model-824 , Chain Roller Shaft Part No- 630B000000081 Model-824 , Shim Set Part No- Ga16ax Model-824 , Bearing Cone Part No- G403 Model-824 , Bearing Cup Part No- G416 Model-824 , Chain Roller Part No- 630C000000083 Model-824 , Gasket Part No- Sga32a Model-824 , Seal Part No- S2300 Model-824 , Grease Fitting Part No- P2fg Model-824 , Retainer Plate Part No- 630A000000138 Model-824 , Chain Roller Cap Part No- 630B000000084 Model-824 , Chain Roller Shaft Part No- 021B000000052 Model-824 , Bearing Part No- G121 Model-824 , Roller, Bucket Chain Part No- 021A000000053 Model-824 , Lock Washer Part No- L49 Model-824 , Lock Nut Part No- L819 Model-824 , Spring Washer Part No- W24gf Model-824 , Hex Nut Part No- T24gg Model-824 , Bucket Chain Part No- 824M000000157 Model-824 , Bucket Chain Assy Part No- 630M000002361 Model-824 , End Link Pin Part No- 621A000000666b Model-824 , Cylinder Assy Part No- 803M000000099 Model-824 , Collar Assy Part No- 00Eb000000037 Model-824 , Rocker Arm Cable Part No- 630B000002487 Model-824 , Cable Spring Part No- 630A000000042 Model-824 , Bumper Spring Part No- 024B000000220 Model-824 , Pin Part No- 803B000000138 Model-824 , Cable Pin Part No- Hra196 Model-824 , Hex Nut, Nyloc Part No- L213 Model-824 , Cotter Pin Part No- L163 Model-824 , Rocker Arm R.H. Part No- 824M000000380 Model-824 , Rocker Arm L.H. Part No- 824M000000378 Model-824 , Rocker Arm Yoke Bar Part No- 824D000000101 Model-824 , Air Motor Assy Part No- 201M000005046 Model-824 , Gasket For Motor Housing Part No- 021A000000196 Model-824 , Wrist Pin Assembly Part No- 201M000000086 Model-824 , Cylinder Part No- 201C000000744 Model-824 , Cylinder Gasket Part No- 201A000000064 Model-824 , Bearing Part No- G267 Model-824 , O Ring Part No- 621A000000545 Model-824 , Valve Housing Cover Part No- 271C000000020 Model-824 , Ext Circlip 5100-255 Part No- L1126 Model-824 , Bearing Part No- G134 Model-824 , Oil Ring Part No- 201A000000073 Model-824 , Piston Part No- 201C000000054 Model-824 , Comp. Ring Part No- 201A000000072 Model-824 , Vent Cap Assy Part No- 200M000000084 Model-824 , Drain Cock, Valve Part No- Bp2rve Model-824 , Plug, Sq.Head Part No- P2fp Model-824 , Crank Shaft Group Plain Part No- 201M000000465 Model-824 , Bearing Part No- G278 Model-824 , Bushing Part No- 201A000000049 Model-824 , Crank Sleeve Part No- 201B000000759 Model-824 , Retaining Ring Part No- 201A000000048 Model-824 , Connecting Rod Part No- 201E000000053 Model-824 , Bearing Adaptor Part No- 201A000000733 Model-824 , Crank Shaft Assy Part No- 201M000000761 Model-824 , Hex Head Bolt Part No- T8hg24 Model-824 , Cap Screw Washer Part No- 201A000000099 Model-824 , Rotary Valve Part No- 271D000000002 Model-824 , Valve Housing Part No- 271E000000004 Model-824 , Motor Housing Part No- 201E000000763 Model-824 , Pitcher Tee Part No- 623A000002559 Model-824 , Elbow M / F Taper Seat Part No- Bp7bsla Model-824 , Sediment Trap Assy. Part No- 623M000002511 Model-824 , Union Elbow, 90 Degree F / F Part No- Bp7bsl Model-824 , Union Part No- Bp7bsa Model-824 , Union, Female Part No- Bp7bs Model-824 , Elbow, Std.90 Degree F / F Part No- Bp7bl Model-824 , Elbow Std 45 Deg. Part No- P9bla Model-824 , Elbow Street, 45 Degree M / F Part No- Bp7blc Model-824 , Close Nipple Part No- Bp9fna Model-824 , Nipple Part No- Bp7fna Model-824 , Elbow, 45 Degree F / F Part No- Bp7bla Model-824 , Stand Pipe Part No- 623A000002655 Model-824 , Hose Clip Part No- P105phb Model-824 , Stand Pipe ( 1 1 / 4 Bspt ) Part No- 621A000000202 Model-824 , Hose Clamp Part No- P9phb Model-824 , Hose Clip Part No- P13phb Model-824 , Hose Clamp Part No- P10phb Model-824 , Nipple Part No- Bp7fn40 Model-824 , Nipple Part No- Bp7fn32 Model-824 , Nipple Part No- Bp7fn20 Model-824 , Nipple Part No- Bp7fn28 Model-824 , Nipple Part No- Bp7fn44 Model-824 , Nipple Part No- Bp7fn48 Model-824 , Nipple Part No- Bp9fn30 Model-824 , Nipple Part No- Bp7fn34 Model-824 , Air Control Valve Assy Part No- 824M000000272 Model-824 , Air Control Valve Assy. Part No- 824M000000274 Model-824 , Control Handle Assy Part No- 623C000003187 Model-824 , Control Handle Assy.L.H. Part No- 623C000003195 Model-824 , Link Part No- 623A000003189 Model-824 , Link Part No- 623A000003190 Model-824 , Pin Part No- 623A000003191 Model-824 , Pin Part No- 623A000003856 Model-824 , Valve Manifold ( Traction ) Part No- 824C000000267 Model-824 , Tab Washer Part No- Sd014 / 019 Model-824 , E Clip - 9 Mm Part No- Sc020 / 012 Model-824 , Valve Manifold Part No- 824C000000294 Model-824 , Control Handle Part No- 824C000000295 Model-824 , Air Control Vlv Assy-Service Part No- 824B070000011 Model-824 , Latch Part No- 824B000000268 Model-824 , Valve Handle Grip Part No- 621A000000110 Model-824 , Cap Part No- 024B000000794 Model-824 , Spacer Part No- Gsa8d Model-824 , Spring Part No- 824A000000277 Model-824 , Hex Socket Head Cap Screw Part No- T8gmn32 Model-824 , Gasket For Cont.Valvebody Part No- 824B000000215 Model-824 , Bush Part No- Sd001 / 014 Model-824 , Flat Washer Part No- W8ga Model-824 , Spring Washer Part No- W6gf Model-824 , Valve End Plate. Part No- 824M000000269 Model-824 , Swivel Assy Part No- 623M000004263 Model-824 , Oiler Head Assy Part No- 623M000002749 Model-824 , Screen Oiler Cap Part No- 630A000000273 Model-824 , Oiler Filler Plug Part No- 630A000000271 Model-824 , Drain Cock Part No- Bp3rvd Model-824 , Air Screen Part No- 012A000000076 Model-824 , Lock Washer Part No- Lla5 Model-824 , Gasket Part No- Sga24a Model-824 , Flat Washer Part No- Wa1 Model-824 , Flat Washer Part No- Wa2 Model-824 , Bucket Bottom, Cast Part No- 824D000000229 Model-824 , Bucket Assy. ( 0.425 Cu.M. ) Part No- 824M000000231 Model-824 , Hull Group Part No- 824M100000013 Model-824 New , Basic Gear Box Part No- 824M100000014 Model-824 New , Square Head Plug Part No- P4bp Model-824 New , Gear Box Part No- 824M000000314 Model-824 New , Spacer ( Large ) Part No- 824B000000401 Model-824 New , Spacer ( Small ) Part No- 824B000000402 Model-824 New , Tab Washers Part No- Sd014 / 065 Model-824 New , Tab Washers Part No- Sd014 / 013 Model-824 New , Tab Washer Part No- Sd014 / 063 Model-824 New , Wheel Assy. Part No- 824A070000012 Model-824 New , Tyre 7.00X12x14 Ply Part No- 824A050000006 Model-824 New , Upper Deck Group Part No- 824B070000013 Model-824 New , Motor Mtg. Cover Part No- 201C000005043 Model-824 New , Motor Housing Assy Part No- 201M000000762 Model-824 New , Hex Head Plug ( Bsp ) Part No- Sc036 / 009 Model-824 New , Crank Shaft Group Part No- 201M000005052 Model-824 New , Bucket Drive Housing Part No- 824E000000333 Model-824 New , Upper Deck Part No- 824C020000033 Model-824 New , Rail Thrust End-Rh Part No- 824D000000344 Model-824 New , Rail Thrust End-Lh Part No- 824D000000345 Model-824 New , Rocker Arm Group Part No- 824M000000382 Model-824 New , Pneumatic Control Group Part No- 824B070000016 Model-824 New , Oiler Bottle Assy. Part No- 630M000005161 Model-824 New , Air Control Valve Assy.-Traction Part No- 824B070000014 Model-824 New , Air Control Valve , Service Part No- 824B070000015 Model-824 New , Ball Valve Part No- 150A050000039 Model-824 New , Needle Valve Part No- 150A050000033 Model-824 New , Tee, Special Part No- 824A020000024 Model-824 New , Tee, Reducing Branch Part No- Bp8bts7 Model-824 New , Coupling Part No- Stdd017 / 012 Model-824 New , Bearing Cup / Cone Part No- G484 / 803A000000022 , Bearing Cup / Cone Part No- G427 / 444 , Bearing Cup / Cone Part No- G448 / 449 , Bearing Cup / Cone Part No- G546 / 547 , Bearing Cup / Cone Part No- G548 / 549 , Bearing Cup / Cone Part No- G562 / 563 , Bearing Cup / Cone Part No- G533 / 534 , Bearing Cup / Cone Part No- G531 / 532 , Bearing Cup / Cone Part No- G403 / 416 , Bearing Cup / Cone Part No- G510 / G511
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 1
49.
Science and Technology #10055799 Price Bid
Tender For Renovation / Refurbishment / Upgradation Works In Health Centre At Csir-Cecri, Karaikudi.; 1 Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : 2 Of area 3 sq. metres and below 3 Of area beyond 3 sq. metres 4 Dismantling aluminium/ Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable material and stacking of serviceable material with in 50 meters lead as directed by Engineer- in-charge. 5 Dismantling wood work in frames, trusses, purlins and rafters up to 10 metres span and 5 metres height including stacking the material within 50 metres lead : 6 Of sectional area 40 square centimetres and above 7 Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. 8 For thickness of tiles 10 mm to 25 mm 9 Dismantling the existing old damaged wash basin & sink including necessary fittings as directed by the Engineer-in-charge. 10 Dismantling W.C. Pan of all sizes including disposal of dismantled materials including malba all complete as per directions of Engineer-in-Charge. 11 Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead of: 12 G.S. Sheet 13 Demolishingbrickworkmanually/bymechanicalmeansincluding stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. 14 In cement mortar 15 Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge. 16 Closing the minor holes upto 0.10sqm area in existing mansonry wallls with necessary plastering and neat finishing as directed by the Engineer-in-charge 17 Removing old unnecessary clamps , angles ,curtain rods and other unwanted minor parts projected in walls & roofs. the rate inclusive of all lift and leads including necessary scaffolding as directed by the Engineer-in-charge. 18 Removing and placing the existing wooden furnitures and other movable items after executing the work including proper placing, cleaning wherever & whenever required as directed 19 Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. 20 Nominal concrete 1:3:6 or richer mix (including equivalent design mix) 21 Demolishing the existing wethering course laid in roofs and including disposal / levelling near the site as directed. 22 Supplying chemical emulsion in sealed containers including delivery as specified. 23 Chlorpyriphos/ Lindane emulsifiable concentrate of 20% 24 Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : 25 Along the external wall below concrete or masonry apron [email protected] linear metre including drilling and plugging holes etc.: 26 With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration 27 Treatment of existing masonry using chemical emulsion @ one litre per hole at 300 mm interval including drilling holes at 45 degree and plugging them with cement mortar 1:2 (1 cement : 2 coarse sand) to the full depth of the hole : 28 With Chlorpyriphos/Lindane E.C. 20% with 1% concentration 29 Providing and injecting approved grout inproportion recommended by the manufacturer into cracks/honey-comb area of concrete/masonry by suitable gun/pump at required pressure including cutting of nipples after curing etc. complete as per directions of Engineer-in-Charge. (The payment shall be made on the basis of actual weight of approved grout injected.) 30 Stirrer mixed SBR Polymer (of approved make) modified Cement slurrymade with Shrinkage Compensating Cement in concrete/RCC work. 31 Providing, mixing and applying bonding coat of approved adhesive on chipped portion of RCC as perspecifications and direction of Engineer- In-charge complete in all respect. 32 Epoxy bonding adhesive having coverage 2.20 sqm/kg of approved make 33 Repair to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sqm and under, including cutting the patch in proper shape, raking out joints and preparing plastering the wall surface with white cement based polymer modifiedself curing mortar, including disposal of rubbish, all completeas per the direction of Engineer-In-Charge. 34 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 35 All kinds of soil. 36 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 and for all lift. 37 Providing and laying in position excluding cement concrete of level: specified grade the cost of centering and shuttering - All work up to plinth 38 1:4:8 (1Cement : 4 coarse sand (zone-Ill) derived from natural sources: 8 graded stone aggregate 40 mm nominal size derived from natural sources) 39 1:2:4 (1cement : 2 coarse sand (zone-Ill) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) 40 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: 41 Cement mortar 1:6(1 cement :6 coarse sand) 42 Brick work with clay flyash F.P.S. (non modular) brick of class designation 7.5 in superstructure above plinth level up to floor five level in : 43 Cement mortar 1:6 (1 cement: 6 coarse sand) 44 Half brick masonry with non modular fly ash bricks of class designation 10, conforming to IS :12894, in super structure above plinth upto floor V level. 45 Cement mortar 1 : 4 (1 cement : 4 coarse sand) 46 12 mm cement plaster of mix: 47 1:6 (1 cement: 6 coarse sand) 48 Providing and laying in position specified grade of reinforced cement concrete,excludingthecostofcentering,shuttering,finishingand reinforcement - All work up to plinth level : 49 1:1.5:3(1 cement: 1.5 coarse sand (zone-Ill) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) 50 Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15 degree landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). 51 Providing,transporting,hoistingandfixingaboveplinthlevelupto floor five level precast reinforced cement concrete in shelves, including setting in cement mortar 1:3 (1cement : 3 coarse sand), cost of required centering, shuttering and finishing with neat cement punning on exposed surfaces but, excluding the cost of reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources: 3 graded stone aggregate 20 mm nominal size derived from natural sources). 52 Steelreinforcement forR.C.C.workincludingstraightening,cutting, bending, placing in position and binding all complete upto plinth level. 53 Thermo-Mechanically Treatedbars of gradeFe-500D or more. 54 Centering and shuttering including strutting, propping etc. and removal of form for 55 Lintels,beams,plinthbeams,girders,bressumersand cantilevers 56 Providing precast cement concrete Jali 1:2:4 (1 cement : 2 coarse sand (zone-Ill) : 4 graded stone aggregate 6 mm nominal size), reinforced with 1.6 mm dia mild steel wire, including centering and shuttering, roughening cleaning, fixing and finishing in cement mortar 1:3 (1 cement: 3 fine sand) etc. complete, excluding plastering of the jambs, sills and sofits. 57 50 mm thick 58 Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately). 59 Second class teak wood 60 Providing and fixing ISI marked flush door shutters conforming to IS : 2202(PartI)non-decorative type,core of blockboardconstruction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 61 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws 62 Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). 63 Providing and fixing factory made single extruded WPC (Wood Polymer Composite)soliddoor/window/Clerestorywindows&otherFrames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms)fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A categorywithpropertyofbeingtermite/borerproof,water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and lengthcomplete as per direction of Engineer-In- Charge. (M.S hold fast/lugs or SS dash fasteners shall be paid for separately). 64 Note: For WPC solid door/window frames, minus 5 mm tolerance in dimensions i.edepth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. 65 Frame size 45 x 85 mm 66 Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate andnatural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimumcompressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In- Charge. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately) 67 30 mm thick 68 Taking out existing wooden door shutter, repair by cutting, painting etc. and refixing of repaired door shutters to existing door frames, including replacement of hinges with screws, etc. as required, all complete as per the direction of the Engineer-in-charge. 69 Extra for providing vision panel not exceeding 0.1sqm in all type of flush doors (cost of glass excluded) (overall area of door shutter to be measured): 70 Rectangular or square 71 Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. 72 Providing and fixing bright /matt finished Brass tower bolt of approved quality & make with necessary screws etc all complete. 300mm x 10mm 73 Providing and fixing Stainless steel latest ornamental fancy handle 1metrelong including necessary screws as directed by the Enginner- in -charge 74 Providingandfixingaluminiumextrudedsectionbodytubulartype universal hydraulic door closer (having brand logo with ISi, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete. 75 Providing and fixing 150 mm bright finished floor brass door stopper with rubber cushion, necessary brass screws etc. to suit shutter thickness complete 76 Providing and fixing factory made uPVC glazed/wire mesh windows/ doors comprising of lead free uPVC multi-chambered frame, sash and mullion/coupler (where ever required) extruded profiles having minimum wall thickness of 1.70 mm for Series R1 and R2 profiles and 2.10 mm for Series R3 and R4 profiles conforming to EN: 12608 in any shape, colour and design duly reinforced with galvanizedmild steel section madeof requiredshape & size asper CPWDSpecification,uPVC extrudedglazingbeads,interlocksandlnlinesashadaptor(where ever required) of appropriate dimension, EPDM gasket, hardware, SS 304 grade fasteners of minimum8mm dia with countersunk head, comprising of matching polyamide PA6 grade sleeve for fixing frame to finished wall as per IS 1367 : Part 1 to 14, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame, sash & mullion (if required) 77 shall be mitred cut and fusion welded/mechanically jointed duly sealed at all corners, including drilling of holes for fixing hardware and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of approved size and quality, all complete as per approved drawing conforming to CPWD specification & direction of Engineer-in-Charge. Section of steel reinforcement and cross sections of uPVC profiles to be as per design approved by Engineer-in-Charge. Wire mesh / Glazing of plain/ toughened/ laminated/ double glass unit with / without high performance coatings as per design requirements and conforming to IS: 3548 & IS: 16231 shall be paid separately. 78 Note:-StructuraldesignproofcheckedfromaGovernment Engineering Institute,tobeprovidedbythemanufacturerfor (i) Sites with basic wind speed > 45 m/sec as per IS 875 — Part 3 (ii) Sites with structure height more than 20m for all wind speeds Two and half track three panels sliding window with two glazed & one wire mesh panels with Aluminium channel for roller track, wool pile, nylon rollers with SS 304 body. 79 Using R3 series with frame (85 mm & above) x (40 mm & above) & glazed sash (30 mm & above) x (55 mm & above) & fly screen sash (20 mm & above) x (50 mm & above) with zinc alloy (zamak) powder coated handle on every glazedpanelalongwithmulti-pointlocking system. (Height upto 1.8 metre). 80 Fixed window/ ventilator without mullion /transom. 81 Using R2 series with frame (39 mm & above) x (39 mm & above). (Height upto 1.2 metre) 82 Providing and fixing glazing in UPVC window, ventilator shutters and partitions etc. as per the architectural drawings and the directions of engineer-in-charge. With colour glass panes of 4.0 mm thickness 83 Providing and fixing fiber glass mesh mosquito net in UPVC window, ventilator shutters etc. withas per the architectural drawings and the directions of engineer-in-charge. 84 Providing and fixing horizontal cassette roller blinds (Zebra) made of synthetic fabric of polyester /cotton with required pattern . Cassette mounting brackets shall support both the roller tube and the cassette. They must be capable of mounting inside, outside or to the ceiling, with the clutch on either right or left hand side of the roller. Cassette shall be installed to conceal the roller tube and mounting hardware. Cassette shall be made of approximately extruded aluminium and shall be painted with a high quality baked enamel finish, or finished with an anodized finish. Size of cassette depends on the size of blind.Cassette shall be able to accommodate a coordinated fabric insert and as directed by the Engineer-in-charge. 85 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fastenersto be paid for separately) : 86 For fixed portion 87 Powder coated aluminium (minimum thickness of powder coating 50 micron) 88 Forshuttersofdoors,windows&ventilatorsincluding providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) 89 Powder coated aluminium (minimum thickness of powder coating 50 micron) 90 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): 91 With float glass panes of 4.0 mm thickness (weight not less than 10kg/sqm) 92 With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm) 93 Providingandfixingcupboardshutterwith 19mmthickoneside decorative and other side balancing lamination factory pressed BWP grade marine ply as per IS 710 of approved brand including 2 mm thick PVC edge banding tape with hot glue by edge bending machine etc. with auto closing spring loaded hinges (hydraulic type) etc. complete as per direction of Engineer-in-charge. (Payment of providing and fixing auto closing hinges shall be paid separately) 94 Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality. 95 1.0 mm thick 96 Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid board one side white color and other side of board laminted with PVCfoil of minimum 14 micron thickness of approved design pasted with hot melt adhesive for cup boards, work stations and bathroom/ kitchen cabinet etc. of required sizes comprisingof virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate andnatural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread offlame of Class A 97 category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel piano hinges/soft close clip on concealed hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In- Charge.(Note: stainless steel piano hinges/soft close clip on concealed hinges and necessary S.S screws shall be paid separately) 98 18 mm thick 99 Providing and fixing stainless steel fancy handle of approved make fixed with SS screws etc. complete as per direction of Engineer-in-charge. 100 200 mm 101 Providing and fixing bright /matt finished Stainless Steel tower bolt of approved quality & make with necessary screws etc all complete. 100x10mm 102 Providing and fixing special quality bright finished brass cupboard or ward robe locks with four levers of approved quality including necessary screws etc. complete. 103 50 mm 104 Providing M.S. Piano hinges ISI marked IS : 3818 finished with nickel chromium plating grade 1as per IS:1068 and fixing with necessary screws etc., complete. 105 Overall width 35 mm 106 Providing and fixing false ceiling at all heightincluding jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board,all as per manufacturers specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting & frame work with : 12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- Part I 107 Providing and fixing false ceiling at all heights including providing and fixing of frame work made of special sections, power pressed from M.S. sheets andgalvanized with zinc coating of 120 gms/sqm(bothside inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50 mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm 108 long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25 mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, 109 all as per manufacturers specification and also including the cost of making openings for light fittings, grills, difusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : 12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- (Part I) :2011 (Board with BIS certification marks) 110 Providing and Fixing 15 mm thick densified tegular edged eco friendly light weight calcium silicate false ceiling tiles of approved texture of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanising @ 120 grams per sqm including both side) consisting of main T runner suitably spaced at joints to get required length and of size 24x38 mm made from 0.33 mm thick (minimum) sheet, spaced 1200 mm centre to centre, and cross T of size 24x28 mm made out of 0.33 mm (Minimum) sheet, 1200 mm long spaced between mainT at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross T of length 600 mm and size 24 x28 mm made of 0.33 mm thick (Minimum) sheet to be inter locked at middle of the 1200x 600 mm panel to from grid of size 600x600 mm, resting on periphery walls /partitions on a Perimeter wall angle pre-coated steel of size(24x24X3000 mm made of 0.40 mm thick 111 (minimum) sheet with the help of rawl plugs at 450 mm centre to centre with 25 mm long dry wall screws @ 230 mm interval and laying 15 mm thick densified edges calicum silicate ceiling tiles of approved texture in the grid, including, cutting/ making opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc., wherever required. Main T runners to be suspended from ceiling using al. slotted cleats of size 25x35x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm G.I. adjustable rods with galvanised steel level clips of size 85 x 30 x 0.8 mm, spaced at 1200 mm centre to centre along main T. Bottom exposed with 24 mm of all T-sections shall be pre-painted with polyster baked paint, for all heights, as per specifications, drawings and as directed by Engineer-in-Charge. 112 Note :- Only calcium silicate false ceiling area will be measured from wall to wall. No deduction shall be made for exposed frames/opening (cut outs) having area less than 0.30 sqm.The calcium silicate ceiling tile shall have NRC value of 0.50 (Minimum), light reflection >85%, non- combustible as per B.S. 476 part IV, 100% humidity resistance and also having thermal conductivity <0.043 w/mK. 113 Providing and laying Vitrified tiles in floor in diferent sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. 114 Glazed Vitrified tiles Matt/Antiskid finish of size 115 Size of Tile 600 x 600 mm 116 Providingandfixing 18mmthickgangsawcut,mirrorpolished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters,window sills,facias andsimilar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels. 117 Granite stone slab of colour black, Cherry/Ruby red 118 Area of slab over 0.50 sqm 119 Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement: 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. 120 Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3(1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 121 Providing and fixing white vitreous china laboratory sink 32 mm C.P brass waste fitting , suitable felxible PVC waste hose , and 32mm C.P . brass trap with necessary C.P . brass unions complete, including cutting and making good the wall wherever required : Size 600x450x200 mm 122 Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 123 15 mm nominal bore 124 Providing and fixing wash basin with Rackbolt, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste fittings & waste hose of standard pattern,wherever required White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tap 125 Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings. 126 Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : 127 W.C. pan with ISI marked white solid plastic seat and lid 128 Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: 129 White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests 130 Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 131 15 mm nominal bore 132 Providing and fixing PVC multi trap (Nahini trap) with jalli including necessary fittings as directed by the Engineer - in- charge. 100mm dia 133 Providing and fixing CP two way tap of approved quality as directed by the Engineer-in-charge 15mm nominal bore 134 Providing and fixing CP coatedhealth faucet 1.0mtr length of approved quality with necessary fittings and screws as directed by the Engineer - in -charge 135 Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. 136 Providing and fixing PTMT soap Dish Holder having length of 138 mm, breadth 102 mm, height of 75 mm with concealed fitting arrangements, weighing not less than 106 gms. 137 Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 138 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. 139 Providing and fixing PTMT shelf 440 mm long, 124 mm width and 36 mm height of approved quality and colour, weighing not less than 300 gms. 140 Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : 141 Inside size 90x80 cm and 45 cm deep including C.I. coverwithframe(lightduty) 455x610mminternal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : 142 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 143 Providing and fixingPVC SWR pipes Type B conforming to IS:13592 including jointing with necessary fittings as directed by the Engineer-in-charge. 150mm diameter 144 Providing and fixingPVC SWR pipes Type B conforming to IS:13592 including jointing with necessary fittings as directed by the Engineer-in-charge. 110mm diameter 145 Providing and fixingPVC SWR pipes Type B conforming to IS:13592 including jointing with necessary fittings as directed by the Engineer-in-charge. 63mm diameter 146 Excavating trenches by mechinical / manual means of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, for all depth, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m: 147 All kinds of soil 148 Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia 149 ProvidingandfixingChlorinatedPolyvinylChloride(CPVC)pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings and fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 150 20 mm nominal dia Pipes 151 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply and all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall 152 25 mm nominal dia Pipes 153 Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete : 154 25 to 40 mm nominal bore 155 Providing and fixing CPVC ball valve of approved quality, High or low pressure, with plastic floats complete as directed by the Engineer -in -charge. 25 mm nominal bore 156 Providing and fixing granite of 18 mm thick gang saw cut, mirror polished (double side), premoulded and prepolished, machine cut for urinal spearator and similar locations of required size (1300mm x 600mm), approved shade, colour, textureand fixing the walls as per site condition, joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite of any colour and shade 157 Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mmwith fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required : 158 Providing and fixing CP brass urinal half turn valve of aprroved quality as directed by the Engineer-in-charge. 15mm nominal bore 159 Raking out joints in lime or cement mortar and preparing the surface for re-pointing or replastering, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge. 160 Flush pointing with cement mortar 1:3 (1 cement : 3 fine sand) mixed with 2% of integral water proofing compound by weight of cement for pressed clay roof tiles as directed. 161 Providing & Applying polymer modified, flexible cementatiouswaterproofing coating with elastic waterproofing polymers on roofsurface in three coats @14.35 kg /10 sqm. one coat of self priming of cementatious waterproofing polymer(dilution with water in the ratio of 1:1) and two coats of cementatious waterproofing polymer(dilution with water in the ratio of 3:1 ) after scrapping and properly cleaning the surface to remove pre-existing paint film & loose particles till plaster is visible, complete in all respect as per the direction of Engineer-in-Charge. 162 Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. 163 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. 164 Hot finished welded type tubes 165 Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. 166 In stringers, treads, landings etc. of stair cases, including use of chequered plate wherever required, all complete 167 Providing and fixing precoated galvanised iron profile sheets (size, shape andpitch of corrugation as approved by Engineer-in-Charge) of total coated thickness 0.50 mm (base metal of minimum 0.45 mm thickness with total coating thickness of 0.05mm) with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desiredby Engineer-in-charge. The sheet shallbe fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 168 Providingand fixingexpansionhold fasteners onC.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. 169 Wedge expansion type 170 Fastener with threaded dia 12 mm 171 Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. 172 Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content. 173 With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre 174 Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approvedbrandandmanufacture,includingapplyingadditionalcoats wherever required to achieve even shade and colour. 175 Two coats 176 Providing andapplyingplaster of paris putty of 2mm thickness over plastered surface to prepare the surface even and smooth complete. 177 Finishing walls with Acrylic Smooth exterior paint of required shade: 178 New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) 179 Finishing walls with textured exterior paint of required shade: 180 New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm 181 Providing and applying acrylic based granular textured wall coating finish in any shade with spray coat bubble or compact or rustik shade.The rate inclusive of POP punning to the wall with proper level & making grooves and preparation of surface as directed. new work two or more coats applied @ 3.28ltr/10sqm over and including priming coat of exterior primer applied @ 2.20kg/10sqm 182 Cutting holes up to 30x30 cm in walls including making good the same: 183 With common burnt clay F.P.S. (non modular) bricks 184 Providng and fixing precast reinforced cement concrete rings with 25mm thick of size 450mm dia & height 300mm in existing masonry walls with neat finishing as per the direction of Engineer-in-charge. 185 Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. 186 Excavating, supplying, stacking and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in foundation trenches, plinth, sides of foundation etc. complete for all lift. 187 Making through holes in plain or reinforced cement concrete / brick masonry wall with diamond core drilling system by mechanical means as directed100mm dia 188 Providing polishing white pebbles stone for vase fillers outdoor / indoor decoration as directed by the engineer-in-charge. size 20mm to 40mm 189 Providing and fixing wall lining / ceiling factory made moulded WPC ( wood polymer composite)louver panel at all height with contemporary design ,jointing and finishing to a flush finish with recommended screws all as per manufacturers specification including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge. (Excluding the cost of frame work or backing boards) 160 wide x23 mm thick 190 Cutting / Carving of plywood / ACP sheet/WPC/PVC/ cement board with CNCoperations in the required patternas directed by the Engineer-in-charge upto 25mm thick 191 Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, bufing, polishing andmakingcurvature(wherever required)andfittingthesame with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). 192 Making letter with 12mm thick WPC sheet in all colours including neccssary machine cutting andneat finishing with sutable font. Fixing and placing in position at required height with neccssary screws / bolt & nuts. The rate inclusive of all transport charges , scaffolding and neccssary fittings as directed by the Engineer In-charge. 200mm high 193 Providing and fixing PVC beading for corner of the ceramic glazed wall tiles area and positioning as approved by engineer in charge. 194 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: 195 Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture 196 Providing and fixing 9 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in-charge. Pre-laminated particle board with Non -decorative lamination on both sides 197 Providng and fixing precast reinforced cement concrete rings with cover 25mm thick of size 900mm dia & height 300mm by using 6mm mild steel reinforcement 100mm c/c in both direction. The rate inclusive of all lifts and leadsas directed by the Engineer-in-charge. 198 Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying: (a) after surface preparation, first layer of slurry of cement @ 0.488 kg/ sqm mixed with water proofing cement compound @ 0.253 kg/sqm. (b) laying second layer of Fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm. (c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around. (d) fourth and final layer of brick tiling with cement mortar (which will be paid for separately. For the purpose of measurement the entire treated surface will be measured. 199 Weathering course using best quality of broken jelly of 20mm gauge in pure slacked lime (no sand to be added) over roof slab the proportion of brick jelly to lime being 32:12.5 by volume and laid over in a single consolidated to the required design and finished thickness by beating the concrete with wooden beater to the size required slope of approved pattern and keeping the surface constantly wet by sprinkling lime jaggery water as per standard specification and as directed by the departmental officers. 200 Providing and laying pressed clay tiles (as per approved pattern 18 mm nominal thickness of approved size) on roofs jointed with cement mortar 1:4 (1 cement : 4 coarse sand) mixed with 2% integral water proofing compound, laid over a bed of 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand) and finished neat complete. 201 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. 202 Fixed to openings /wooden frames with rawl plugs screws etc. 203 Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double acting hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge (Door handle, lock and stopper etc.to be paid separately). 204 Providing and fixing glass door stainless steel lock of approved quality , design and make with necessary fixing arrangements as directed by the Engineer-in-charge. 205 Supplying and fixing self adhesive decorative film for glass doors/ winows /glass partition/backing of suitable boards including requireddesign as directed by the Engineer-in-charge. 206 Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x 300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design: 207 150 x 100 mm size P type 208 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 209 Supplying and Fixing of stainless steel (304 grade) polished CSIR-Emblemfinished with suitable mounding struds inluding neat finishing at directed by Engineer-in-charge 450mm dia 210 Dismantling doors, windows,wooden board,wooden frames,aluminium partitions,false ceiling materials and clerestory windows (steel ,aluminium or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 1500 metres lead (store yard) : 211 Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement and making necessary channels for the drain etc. complete : 212 For pipes 100 to 250 mm diameter 213 Designing, fabricating, testing, installing and fixing in position Curtain Wall with Aluminium Composite Panel Cladding, with open grooves for linear as well as curvilinear portions of the building , for all heights and all levels etc. including:(a) Structural analysis & design and preparation of shop drawings for pressure equalisation or rain screen principle as required, proper drainage of water to make it watertight including checking of all the structural and functional design. (b) Providing, fabricating and supplying and fixing panels of aluminium composite panel cladding in pan shape in metalic colour of approved shades made out of 3 mm thick aluminium composite panel material consisting of 3 mm thick FR grade mineral core sandwiched between two Aluminium sheets (each 0.5 mm thick). The aluminium composite panel cladding sheet shall be coil coated, with Kynar 500 based PVDF / 214 Lumiflon based fluoropolymer resin coating of approved colour and shade on face # 1 and polymer (Service) coating on face # 2 as specified using stainless steel screws,nuts,bolts, washers,cleats, weather silicone sealant, backer rods etc.(c) The fastening brackets of Aluminium alloy 6005 T5 / MS with Hot Dip Galvanised with serrations and serrated washers to arrest the wind load movement, fasteners, SS 316 Pins and anchor bolts of approved make in SS 316, Nylon separators to prevent bi-metallic contacts all complete required to perform as per specification and drawing The item includes cost of all material & labour component, the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working curtain 215 wall with aluminium compositepanel cladding, cleaning and protection of the curtain wall with aluminium composite panel cladding till the handing over of the building for occupation. Base frame work for ACP cladding is payable under the relevant aluminium items. The Contractor shall provide curtain wall with aluminium composite panel cladding, having all the performance characteristics all complete , as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer-in-Charge. However, for the purpose of payment, only the actual area on the external face of the curtain wall with Aluminum Composite Panel Cladding (including width of groove) shall be measured in sqm. up to two decimal places. 216 Providing and fixing on wall face unplasticisedRigidPVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 217 110 mm diameter 218 Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS :5382, leaving 10 mm gap for thermal expansion. 219 Bend 87.5° 220 110 mm bend 221 Shoe (Plain) 222 110 mm Shoe 223 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable insurface /recessedmediumclassPVCconduit,withmodular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. 224 Group C 225 Wiringfortwincontrollightpointwith 1.5sq.mmFRLSPVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch,modular plate, suitable GI box and earthing the point with1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. 226 Wiringforcircuit/submainwiringalongwithearthwirewiththe followingsizesofFRLSPVCinsulatedcopper conductor,single corecableinsurface/recessedmediumclassPVCconduitas required. 227 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire 228 2 X 4 sq. mm + 1 X 4 sq. mm earth wire 229 2 X 6 sq. mm + 1 X 6 sq. mm earth wire 230 2 X 10 sq. mm + 1 X 6 sq. mm earth wire 231 4 X 2.5 sq. mm + 2 X 2.5 sq. mm earth wire 232 4 X 4 sq. mm + 2 X 4 sq. mm earth wire 233 4 X 10 sq. mm + 2 X 6sq. mm earth wire 234 4 X 16 sq. mm + 2 X 6 sq. mm earth wire 235 Supplyingand drawingfollowingpair 0.5mmdiaFRLSPVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. 236 2 Pair 237 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 238 25 mm 239 Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. 240 100 mm X 100 mm X 60 mm deep 241 200 mm X 150 mm X 75 mm deep 242 200 mm X 300 mm X 100 mm deep 243 Supplying and fixing following modular switch/ socket on the existing modularplate&switchboxincludingconnectionsbutexcluding modular plate etc. as required. 244 5/6 A switch 245 15/16 A switch 246 3 pin 5/6 A socket outlet 247 6 pin 15/16 A socket outlet 248 Telephone socket outlet 249 Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. 250 Supplyingandfixingfollowingsize/modules,GIboxalongwith modular base & cover plate for modular switches in recess etc. as required. 251 1 or 2 Module (75mmX75mm) 252 3 Module (100mmX75mm) 253 6 Module (200mmX75mm) 254 12 Module (200mmX150nnm) 255 Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required. 256 Installation,testingandcommissioningofpre-wired,fluorescent fitting / compact fluorescent fittingof alltypes,complete withall accessoriesand tube/lamp etc.directly on ceiling/ wall,including connectionswith 1.5sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. 257 Numberingofceilingfan/exhaustfan/fluorescentfittingsas required. 258 Wiring for group controlled (looped) light point/fan point/exhaust fan point/call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit,and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. 259 Group C 260 Supplying and fixing following way,horizontal type three pole and neutral,sheetsteel,MOBdistributionboard, 415V,onsurface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 261 4 way (4 + 12), Double door 262 6 way (4 + 18), Double door 263 8 way (4 + 24), Double door 264 Supplyingand fixingof following ways surface/ recessmounting, vertical type, 415 V, TPN MOB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MOB TPDB is normally used where 3 phase outlets are required.) 265 4 way (4 + 12), Double door 266 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, C curve, miniature circuit breaker suitable for inductive load of following poles intheexistingMOBDBcompletewithconnections,testingand commissioning etc. as required. 267 Single pole 268 Double pole 269 Triple pole 270 Supplying and fixing single pole blanking plate in the existing MOB DB complete etc. as required. 271 Supplying and fixing DP sheet steel enclosure on surface/ recess alongwith 25/32A240VCcurveDPMCBcompletewith connections, testing and commissioning etc. as required. 272 Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. 273 Supplying and fixing Cable End Box (Loose Wire Box) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415Volts,onsurface/recess,completewithtestingand commissioning etc.as required. 274 For 4 way, Double door TPN MCBDB 275 For 6 way, Double door TPN MCBDB 276 For 8 way, Double door TPN MCBDB 277 Supplying and fixing Cable End Box (Loose Wire Box) suitable for triple pole and neutral, sheet steel, Vertical MCB distribution board, 415 Volts, on surface/ recess, complete withtesting and commissioning etc. as required. 278 Supplyingandinstallingfollowingsizeof perforatedpaintedwith powdercoatingM.S.cabletrayswithperforationnotmorethan 17.5%,in convenient sections, joined with connectors, suspended fromtheceilingwithM.S.suspendersincludingbolts&nuts, painting suspenders etc as required. 279 150 mm width X 50 mm depth X 1.6 mm thickness 280 300 mm width X 50 mm depth X 1.6 mm thickness 281 Supplyingandinstallingfollowingsizeof perforatedpaintedwith powder coatingM.S.cable traysbends withperforationnot more than 17.5%„ joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 282 150 mm width X 50 mm depth X 1.6 mm thickness 283 300 mm width X 50 mm depth X 1.6 mm thickness 284 Supplyingandinstallingfollowingsizeof perforatedpaintedwith powder coating M.S. cable trays Tee with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspendersincludingbolts&nuts,paintingsuspendersetcas required. 285 300 mm width X 50 mm depth X 1.6 mm thickness 286 Earthing withG.I.earthplate 600mm X 600 mm X 6mm thick including accessories, and providing masonry enclosure with cover plate havinglocking arrangement and wateringpipe of 2.7 metre long etc. with charcoal/ coke and salt as required. 287 Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate havinglocking arrangement and wateringpipe of 2.7 metre long etc. with charcoal/ coke and salt as required. 288 Supplying andlaying 25 mm X 5 mm copper strip at 0.50 metre belowground asstrip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm) 289 Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. 290 Providing and fixing 25 mm X 5 mm GI. strip on surface or in recess for connections etc. as required. 291 Providingandfixing4.00mmdiacopper wireonsurfaceorin recess for loop earthing as required. 292 Providing and fixing earth bus of 50 mm X 5 mm copper strip on surface for connections etc. as required. 293 Laying of one number PVCinsulated andPVC sheathed / XLPE power cable of 1.1KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. 294 Above 35 sq. mm and upto 95 sq. mm 295 Above 95 sq. mm and upto 185 sq. mm 296 Laying of one number PVC insulated andPVC sheathed / XLPE powercableof1.1KVgradeoffollowingsizeintheexisting masonry open duct as required. 297 Above 35 sq. mm and upto 95 sq. mm 298 Above 95 sq. mm and upto 185 sq. mm 299 Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. 300 Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp) 301 Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mmMS flat clamp) 302 Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required. 303 Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp) 304 Supplyingandmakingendterminationwithbrass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1KV grade as required. 305 312 X 70 sq. mm (38mm) 306 3% X 150 sq. mm (50mm) 307 Supplying and fixing of 32 mm dia X 2.00 metres long GI. pipe (medium class) bracket for mounting of fluorescent / HPMV / HPSV street light fitting on pole including bending the pipe to the required shape, 2 nos 40 mm X 3 mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and finish paint etc. as required. 308 Supplying and fixing of light class G.I. pipe of 80 mm dia. (nominal) 3 metres length along the pole for protection of under ground cable as required. 309 Supplying and laying of following sizeDWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc.conforming toIS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 310 90 mm dia (00-90 mm & I0-76 mm nominal) 311 120 mm dia (00-120 mm & ID-103 mm nominal) 312 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLOC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. 313 Removing the existing TPN and SPN DBs,changeover switch Db,SFU’s of all size, Fuse carriers,Main switches, Sub main, circuit and point wirings,switch boards, power boardsfan and light fittings with Various size of cables , removing of Incoming cables/wires for old PDB and LDB and other unused and worn-out electrical installations, and other unwanted Electrical materials in the proposed area complete in all aspects as per site condition and returning the removed items to the departments stores or any such place within the campus area as directed by the engineer in charge as per site condition. 314 Shifting of 15 KVA UPS System (including UPS Unit and Batteries) from passage to proposed new panel room. Scope includes:Disconnecting ,shifting andreconnecting UPS,Batteries (20Nos) power and battery cables, Installation and realignment in new location, Testing and commissioning all required manpower, tools, and accessories as per site condition. 315 LED Street Light Fitting :Supply and fixing ofoutdoor type LED Street light fitting,36W, in the existing pole (up to 40mm dia ) located in site along with all accessories as required as per site condition. Simial to JV Lukers STRADA Model No.LST- 36 or Equivalent as approved by department.(note:The fitting should have 2 years warranty replacement) 316 2 FtLED Batten:Supply of 2 feet extruded aluminium LED batten indoor type 12W, having high efficiency, flicker free suitable for wall, surface and conduit mounting system with required accessories as required. Similar to Philips Endura Smat BrightModel No. BN021 LED12S-6500 PSU GR or Equivalent with time of 25,000 hours as approved by department 317 LED ML Fitting : Supply of LED mirror light fitting of 18 W,WW having high efficiency,wall/ surface mounting with suitbale driver of wide voltage range as required. Similar to JV Lukers LITA T8 Model No.LMCL 18 or Equivalent as approved by department.Note:the fitting shall have 2 years warranty replacement 318 12 Way VTPN DB with 100 A MCCB:Supplying and fixing 12 way surface/ recess MCCB mounting, 415 volts, vertical type TPN MCB distribution board (with wire way/cable end box) of sheet steel,dust protected, duly powder painted, inclusive of 160 amps tinned copperbusbar,commonneutrallink,earthbar,dinbarfor mounting MCBs, along with 100 A,16/25 KA TPN MCCB, phase barrier and spreaders for incomer, interconnection between DB incomer and the bus bars/Existing mains shall be made with copper cables of appropriate rating as required.The VTPN DB shall be mounted on a adequate size angle/flat and grouted/ fixed (drilling,cutting welding painting etc)firmly in the existing wall/ existing base channel as required as per site condition complete in all aspects.The above DB shall include the following C series, 10 kA MCBs in the out going circuits 319 TP MCB-63A-2 NosSP MCB-6-32A-30 NosBlanking plates -As required.Make : Legrand /Schneider /Siemens/Hager or equivalentsubject to the approval of the department. 320 TP +N MCB With Enclosure for AC outdoor:-Supplying and fixing TP+N415 volts, 63 amps,C Series,MCB including Enclosure asrequired as per site condition complete in all aspects . 321 Raceway 100x50 mm: Supply and fixing of100 x 50 mm UPVC cable management complete system / raceway trunking along with all accessories as requiredin surface and carrying out the proposed electrification works complete in all aspects as required as per site condition.Make : MK/ Legrand/Siemens or Eauivalent as approved by department. 322 Raceway 50x50 mm:Supply and fixing of50 x 50 mm UPVC complete cable managementsystem / raceway trunking along with all accessories as requiredin surface and carrying out the proposed electrification workscomplete in all aspects as required as per site condition.Make : MK/ Legrand/Siemens or Eauivalent as approved by department. 323 TP MCB:-Supplying and fixing TP 415 volts, 63 amps,C Series,MCBin the existing DBas required as per site condition complete in all aspects . 324 TP +N MCB:-Supplying and fixing TP+N415 volts, 40 amps,C Series,MCBin the existing DBas required as per site condition complete in all aspects . 325 2x2 LED fitting: Supply and fixing recessed mounting2x2 LED energy efficient fitting, 4200 lumens, around 40 watts,WW/WHalong with suitable driver with ripple less than 5%for flicker/glare-free light in the existing false ceiling with required accessoriessuch as chain/stringfor supporting the fittings firmlyin the ceiling including interconnections as required. Similar to Philips Full Glow G6 Model No : RC380B LED 42S-6500/4000 G6 l60 W60 PSU OD or Equivalent as approved by department.(Note:The Fitting Should have 2 years warranty replacement) 326 2x2 LED fitting: Supply ofrecessed mounting2x2 LED energy efficient fitting, 4200 lumens, around 40 watts,WW/WH along with suitable drive rwith ripple less than 5%for flicker/glare-free light as required. Similar to Philips Full Glow G6 Model No : RC380B LED 42S-6500/4000 G6 l60 W60 PSU OD or Equivalent as approved by department.(Note:The Fitting Should have 2 years warranty replacement) 327 Square/RoundLED down lighter :Supply and fixing ofrecessed mounting Square Down lighter LED energy efficient fitting,1200 lumens, 12W, WW/WH light along with suitable driver in the existing false ceiling with required accessories for mounting the fittings firmlyin the ceiling including interconnections as required. Similar to Philips Sleek surface slim profile SM250/260 LED 12S 6500 PSUor Equivalent as approved by department.(Note:The Fitting Should have 2 years warranty replacement) 328 Square/RoundLED down lighter :Supplyofrecessed mounting Square Down lighter LED energy efficient fitting,1200 lumens, 12W, WW/WH light along with suitable driver in the existing false ceiling with required accessories for mounting the fittings firmlyin the ceiling including interconnections as required. Similar to Philips Sleek surface slim profile SM250/260 LED 12S 6500 PSUor Equivalent as approved by department.(Note:The Fitting Should have 2 years warranty replacement) 329 Smart LED Strip Light : Supply, installation, testing and commissioning of indoor type, 5 mtr, 12 V,25 W,2200 lumens, Smart WiFi Tunable white strip light that works works with voice/ WiZ connected/remote based application along with suitable AC driver of continuous duty,etc having an adhesive for firm fixing and2 years replacement warranty etc.The strip light shall be installed in the existing confernce room wall panel/ false ceilingwith required accessories, interconnections of adequate rated cables complete in all aspects as required as per site condition. Similar to Phlips 5 Mtr WiZ Smart Strip LightProduct SKU : 929003551501 or equivalent as approved by department. 330 4 Ft Industrial LED Batten:Supply of standard 4 feet industrial indoor 40W,LED batten having high efficiency, flicker free suitable for wall, surface and conduit mounting system with required accessories as required. Similar to Philips Endura LED Next Model No. BN308CLED40S-6500 L1 PSD or Equivalent as approved by department.(Note:The LED batten shall have minimum 2 years relacement warranty.) 331 LED Wall Lamp : Supply, installation, testing and commissioning of indoor type bigwall mounted modern creative light fixture LED wall lampmade up of glass or combination of metal and crystal material having Gold/Shining lamp shade, Bold vibe, Abstract pattern and the model will be selected by the engineer in-charge . the basic amount of the fitting should be reckoned as Rs 5000/ (± 5%) excluding GST. operating with AC source of power supply, having a replacement warranty of 1 year, complete with wall lamp and bulb to be suitably mounted in the wall mounting panel and other structures with required accessories, interconnections of adequate rated cables complete in all aspects as required as per site condition. 332 LED Silicon Neon Profile Tube Light Lighting: Supply, installation, testing and commissioning of indoor type, 10 mtr, 24 V,75 W,vibrant lighting with low energy consumptionalong with suitable AC driver of continuous duty,etc having an adhesive for firm fixing and2 years replacement warranty etc.TheProfile Tube Light shall be installed with different meter length in the existing conference room wall panel/ false ceilingwith required accessories, interconnections of adequate rated cables complete in all aspects as required as per site condition. Similar to Harold 10 Mtr Silicon Neon Profile Tube Light or equivalent as approved by department. 333 Butterfly Gold LED Wall Lamp:Supply, installation, testing and commissioning of indoor type bigwall mounted modern CITRA Transparent Acrylic Butterfly Gold LED Wall Lamp Bedside Light - Warm Whitemade up of Metal or combination of metal and crystal material having Gold lamp shade, Bold vibe, Abstract pattern and minimum dimension of 24Lx19Wx12H CM, AC source of power supply, having a replacement warranty of 1 year, complete with wall lamp and bulb to be suitably mountedin the wall mounting panel and other structures withrequired accessories, interconnections of adequate rated cablescomplete in all aspects as required as per site condition. Similar to CITRA Transparent Acrylic Butterfly Gold LED Wall Lamp Bedside Light - Warm White or equivalent as approved by the department. 334 Sun flower Wall Lamp:Supply, installation, testing and commissioning of indoor type bigwall mounted modern Lamp master 3-in-1 LED Sunflower Wall made up of Acrylic or combination of metal and crystal material having Lamp master 3-in-1 LED, Abstract pattern and minimum dimension of 23Lx5Wx23H CM, AC source of power supply, having a replacement warranty of 1 year, complete with wall lamp and bulb to be suitably mountedin the wall mounting panel and other structures withrequired accessories, interconnections of adequate rated cablescomplete in all aspects as required as per site condition. Similar to Lamp master 3-in-1 LED Sunflower Wall & Ceiling Light - Creative Acrylic Decorative Wall Light or equivalent as approved by the department. 335 Exhaust fan CATA C B15 Matic: Supplyingand fixing of window mounted plastic housing of industrial type white colour exhaust fan,automatic shutter, 220-240 V 50 Hz,class B insuslation, theramal cutout,43 dB noise level, 40 Deg ambient, 320 CFM suitable for 150 Sq Ft size room in the existing window of the bathroom as required with necessary accessories, interconnection etc as per site condition. Similar to CATA C B15 Maticor equivalent as approved by department. 336 Supply of constant current LED Driver suitable for 2x2’ Full Glow LED Fitting, with thespecifications is Input Voltage: 140–270V AC, Output: Constant current, suitable for 36W–40W LED, Power Factor: ≥0.95, THD: <10%, Surge Protection: ≥4kV, Efficiency: ≥85%, Specify approved make or “equivalent” 337 Supply of LED Driver for Down lighter LED fitting 12W, 1200 Lumens, WW/WH color. Input: 220-240V AC Output: 12V/Constant Current, PF > 0.9 , Efficiency > 85% , THD < 15%, CE/RoHS compliant andSpecify approved make or “equivalent”. 338 Supplyand installtion of Rubber mat of size (100X200) cm as persite condition at VTPN DB area of thickness as per standard IS 15652. 339 Supplying & fixing of ariel clamp set of Suitable angle for fixing following HRC Fuse Base and Fuselink on the LT polewith 250 AMPS HRC Fuse base (make: L&T) and 250 A HRC Fuse link (make:L& T) with necessary accessories assembled as complete set and mounted in the existing LT pole along with the termination of UG cable as required as per site condition. 340 Dispensary MV Distribution Panel a) Supply, installation, testing and commissioning of In Door type panel manufactured by a CPRI approved panel fabricator compling IS standards.LT Panel Sheet thickness should not be less than 2.00 mm for load bearing members and doors and LT panel cubicle/vertical should be with 9 fold design structure for more strength, with detachable gland plates of 3mm thick for entry of cables from the top/bottom as required with 400A ratings electrolytic copper bus bars with sleeves (100% for phases & 50% neutral & as per standards for earth running all around the panel), free standing, totally enclosed, suitable for 3 phase and neutral. The panel should be modular in design with ZERO welding and suitable for 415 V, 3 phases, 50 Hz, 4 wire systems IP 43 & IK09. The LT panel bus bars shall be supported with the Glass reinforced Polyamide 6.6 type bus bar support suitable up to 140 deg C. Main incoming & outgoing switchgear/circuit breakers should be of same manufacturer and switchgear should be of same series/model of the OEM. 341 No live part should be accessible from the front, while operating the door. Total Discrimination chart should be prepared for all the LT panels & should be submitted before approval along with GA Drawing. Incomer :- 1 No’sof 320 Amps 4 pole Changeover switch parallel with a separate suitable HRC fuse carrier set along with neutral bus on the load side with necessary interconnections as required as per standards etc, direct rotary handle, 2 set of spreader terminal, phase barrier,intersource barrier, shorting links set of 4,415/690 V AC, 100 % Neutral,12.5 kA, insulation voltage of 1000 V Ac, impulse voltage of 12 kV, mechanical and electrical rating of 10000 and 2000 cycles respectively confirming to IS as amended up to date complete withall otheraccessories etc as required. Similar to TSE power line, Frame-2 Cat No.424188 of Legrand or equivalent as approved by department. 342 i) Digital multifunction meter class 1 accuracy, with Rs 485 portoutput for communication toread V, A, F, PF, kW, kVA, kVAR, kWh, kVAh, kVARh, etc - 1No.ii) 320A/5A CL.1 accuracy, 15VA burden CT - 3 Nos.iii) RYB and ON, OFF, indication lamps for both source connected with suitable control fuse and MCB -1 Set.Outgoing: 8 No’s of100 Amps TPN MCCB (Icu=10 kA=Ics )Thermal magnetic based, 415V, 100% Neutral, rating confirming to IS as amended up to date complete with over current & short circuit protection, spreaders, phase barriers, direct rotary handle etc with required interconnections as required complete in all aspects as required 343 Erection in all aspect including providing necessary angle iron channels for the panel to be mounted on the existing trench/brickwork/panel room, with required fastners, accessories and other allied works deemed to be required to complete as per site condition (including necessary civil works as required and finishing the same to the original condition, along with cable excavation for loose/loop purpose as required.) 344 Supply, fabrication, and installation of CRCA metal enclosure with sealing arrangments as per EB requirements, 2 MM thickness (powder coated) of minimum size 400mm (W) x 300mm (D) x 500mm (H)along with electrolytic copper bus bar rated for 300A, mounted inside the enclosure with suitable supports, sleeves, and interconnections for incomer and outgoing connections and3mm thick detachable gland plates for 150 Sqmm aluminium cable entry from top/bottom as required. The cable end box shall be mounted on a adequate size angle/flat and grouted/ fixed (drilling, cutting welding painting etc) firmly in the existing wall/ existing base channel as required as per site condition complete in all aspects. 345 Shifting of TNEB Metering Board Three Phase: a)Supplying and fixing of suitable size of teakwood plank for fixing of existing meter and other accessories as required.b) Supplying and fixing of required 03 nos of 63A-100A porcelain fuse unit. c)Supplying and Fixing of copper earth strip of size 19mm X 3mmthick of6`` length for earth connections as reqd. The above complete set has to be mounted on wall. The charge including all interconntions and masonry works etc. d)Re fixingor shifting of Existing Meters (10-60A) with new boards including remitting of necessary charges to TNEB for meter shifting on behalf of CSIR-CECRI and co-coordinating with TNEB officials in all aspects in order to charge the meteringboard complete as required.
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 2
50.
New and Renewable Energy #10053821 Price Bid
Rate Contract For Spares For Eimco Elecon Make Equipment Rate Contract For Spares For Eimco Elecon Make Equipment , Rate Contract For Spares For Eimco Elecon Make Equipment , Arm Assembly Part No917a070000001 Model 907 , Bush,Metric Part Nombh100/116/70A Model 907 , Bush (Metric) Part Nombh100/116/50A Model 907 , Pin Part No917a060000007 Model 907 , Lock Plate Part No917a060000001 Model 907 , Hex Socket Head Cap Screw Part No370-2411 Model 907 , Spring Washer Part Nomdw12sa Model 907 , Grease Nipple Part Nobp1fg Model 907 , Pin Part No917a060000014 Model 907 , Lock Plate Part No917a060000005 Model 907 , Hex Socket Head Cap Screw Part No370-2311 Model 907 , Spring Washer Part Nomdw10sa Model 907 , Bush Part Nombh125_135_101 Model 907 , Lever Assembly Part No917a070000002 Model 907 , Bush (Metric) Part Nombh125/145/85A Model 907 , Bush (Metric) Part Nombh90/106/100A Model 907 , Pin Part No917a060000008 Model 907 , Lock Plate Part No917a060000002 Model 907 , Hex Socket Head Cap Screw Part No370-2311 Model 907 , Spring Washer Part Nomdw10sa Model 907 , Grease Nipple Part Nobp1fg Model 907 , Bush Part Nombh90_98_60 Model 907 , Link Assembly Part No917a070000006 Model 907 , Pin Part No917a060000009 Model 907 , Lock Plate Part No907a060000006 Model 907 , Hex Socket Head Cap Screw Part No370-2311 Model 907 , Spring Washer Part Nomdw10sa Model 907 , Grease Nipple Part Nobp1fg Model 907 , Bush(Metric) Part Nombh90/106/60A Model 907 , Push Plate Bucket Assy. Part No907b070000063 Model 907 , Bucket Lip Part Noeea0032174 Model 907 , Twisting Bumper Part No19wl429091510 Model 907 , Spacer Part No19wl425091303 Model 907 , Washer Part No19wl425091304 Model 907 , Hex Head Screw Part Nomt12lg40g Model 907 , Plate Part Noeea0005530 Model 907 , Locking Ring Part Noeea0002017 Model 907 , Lock Ring Part Nossla020000023 Model 907 , Push Plate Upper Mac. Part No907b020000089 Model 907 , Push Plate Lower Part No907b020000090 Model 907 , Pin, Push Plate Lower Part No907a060000008 Model 907 , Pin, Push Plate Upper Part No907a060000009 Model 907 , Hex Head Bolt Part Nomt10lg65g Model 907 , Spring Washer Part Nomdw10sa Model 907 , Hex Nut, Nyloc Part Nomt10ln Model 907 , Push Plate Cylinder Part No907b050000080 Model 907 , Tube S/A-2 Part Noeea0032090 Model 907 , Piston Rod S/A Part Noeea0032091 Model 907 , Head End Cover Part Noeea0032092 Model 907 , Piston Part Noeea0028785 Model 907 , Retainer Part Noeea0028786 Model 907 , Snap Ring Part Noeea0028787 Model 907 , Grub Screw, Piston Part Noeea0024567 Model 907 , Gub Screw Part Noeea0023564 Model 907 , Circlip Part Noeea0022817 Model 907 , Spherical Bearing Part Nostdc003/036 Model 907 , Grease Nipple With Cap Part Noeea0020796 Model 907 , Bush Part Noeea0023556 Model 907 , Piston Seal Ring (*) Part Noeea0023563 Model 907 , Piston Wiper Ring (*) Part Noeea0023562 Model 907 , Piston Rod O-Ring (*) Part Noeea0023561 Model 907 , Back Up Ring (*) Part Noeea0023560 Model 907 , O-Ring (*) Part Noeea0023555 Model 907 , O-Ring (*) Part Noeea0023554 Model 907 , Step Seal (*) Part Noeea0023558 Model 907 , Rod Seal (*) Part Noeea0023559 Model 907 , Wiper Seal (*) Part Noeea0023747 Model 907 , Seal Kit (* Items ) Part Noeea0032093 Model 907 , Pin (Bucket) Part No907a060000004 Model 907 , Pin, Upper Push Plate Part No907a060000007 Model 907 , Pin Part No917a060000010 Model 907 , Bush (Metric) Part Nombh100/116/55A Model 907 , Bush (Metric) Part Nombh90/106/100A Model 907 , Spacer Part No811a060000106 Model 907 , Lock Plate Part No907a060000010 Model 907 , Grease Nipple Part Nobp1fg Model 907 , Hex Socket Head Cap Screw Part No370-2309 Model 907 , Hex Socket Head Cap Screw Part No370-2311 Model 907 , Hex Head Bolt Part No370-0326 Model 907 , Spring Washer Part Nomdw10sa Model 907 , Hex Nut, Nyloc Part Nomt10ln Model 907 , Front Frame Assembly Part No917a070000003 Model 907 , Locking Ring Part Noeea0003926 Model 907 , Pin Assy. Part No917a020000001 Model 907 , Pin Part No917a060000017 Model 907 , Chain Part No103451 Model 907 , Hex Socket Head Cap Screw Part No370-2409 Model 907 , Spring Washer Part Nomdw12sa Model 907 , Pin Part No917a060000015 Model 907 , Hex Socket Head Cap Screw Part No370-2329 Model 907 , Spring Washer Part Nomdw10sa Model 907 , Hex Nut Part No369-0110 Model 907 , Pin Part No917a060000012 Model 907 , Lock Plate Part No907a060000011 Model 907 , Hex Socket Head Cap Screw Part No370-2311 Model 907 , Grease Nipple Part Nobp1fg Model 907 , Pin Part No917a060000013 Model 907 , Lock Plate Part No917a060000002 Model 907 , Lock Plate Part No917a060000004 Model 907 , Pin Part No917a060000011 Model 907 , Spherical Bearing Part Nostdc003/056 Model 907 , Seal Part Noseg251 Model 907 , O Ring Part Noseg1099 Model 907 , Hex Socket Head Cap Screw Part No370-2232B Model 907 , Wear Washer Part No912b060000117 Model 907 , Plate Part Noeea0024855 Model 907 , Bush (Metric) Part Nombh70/82/100A Model 907 , Bush Part Nombh100_110_64 Model 907 , Bush Part Nombh100_110_68 Model 907 , Bush Part Nombh90_100_78 Model 907 , Bush Part Nombh90_100_82 Model 907 , Wheel Arch Lh Part No917a020000010 Model 907 , Wheel Arch Rh Part No917a020000011 Model 907 , Guard Part No917a020000012 Model 907 , Clamp Part No917a020000009 Model 907 , Front Axle Part No917b050000011 Model 907 , Axle Housing Part Noeea0025425 Model 907 , Breather Part Noeea0025426 Model 907 , Screw Plug Part Noeea0025427 Model 907 , Sealing Ring Part Noeea0025428 Model 907 , Screw Plug Part Noeea0025429 Model 907 , Sealing Ring Part Noeea0025430 Model 907 , Axle Shaft Part Noeea0025431 Model 907 , Wheel Stud Part Noeea0025434 Model 907 , Ring Part Noeea0025435 Model 907 , Radial Seal Ring Part Noeea0025436 Model 907 , Radial Seal Ring Part Noeea0025437 Model 907 , Tapered Roller Bearing Part Noeea0025438 Model 907 , Tapered Roller Bearing Part Noeea0025439 Model 907 , Ring Part Noeea0025440 Model 907 , Nut Part Noeea0025441 Model 907 , Hexagon Socket Screw Part Noeea0025442 Model 907 , O-Ring Part Noeea0025443 Model 907 , Sealing Ring Part Noeea0025444 Model 907 , Inner Disk Part Noeea0025445 Model 907 , Outer Disk Part Noeea0025446 Model 907 , Brake Group Kit Part No907a070000085 Model 907 , Piston Part Noeea0025447 Model 907 , Gasket Part Noeea0025448 Model 907 , Gasket Part Noeea0025449 Model 907 , Brake Carrier Part Noeea0025450 Model 907 , Brake Housing Part Noeea0025451 Model 907 , O-Ring Part Noeea0025452 Model 907 , O-Ring Part Noeea0025453 Model 907 , O-Ring Part Noeea0025454 Model 907 , Hexagon Socket Screw Part Noeea0025455 Model 907 , Hexagon Socket Screw Part Noeea0025456 Model 907 , Face Seal Part Noeea0025457 Model 907 , Screw Plug Part Noeea0025458 Model 907 , Sealing Ring Part Noeea0025459 Model 907 , Bleeding Socket Part Noeea0025460 Model 907 , Sealing Ring Part Noeea0025461 Model 907 , Bleeder Valve Part Noeea0025462 Model 907 , Compression Spring Part Noeea0025463 Model 907 , Compression Spring Part Noeea0025464 Model 907 , Intermediate Piece Part Noeea0025465 Model 907 , Piston Guide Ring Part Noeea0025466 Model 907 , Warning Label Part Noeea0025467 Model 907 , O-Ring Part Noeea0025468 Model 907 , Thread Bushing Part Noeea0025469 Model 907 , O-Ring Part Noeea0025472 Model 907 , Cap Part Noeea0025473 Model 907 , Planetary Housing Part Noeea0025474 Model 907 , O-Ring Part Noeea0025475 Model 907 , Screw Plug Part Noeea0025476 Model 907 , Disk Part Noeea0025480 Model 907 , Hexagon Socket Screw Part Noeea0025481 Model 907 , Sun Gear Part Noeea0025482 Model 907 , Bushing Part Noeea0025483 Model 907 , Hexagon Socket Screw Part Noeea0025484 Model 907 , Ring Part Noeea0025485 Model 907 , Planetary Gear Part Noeea0025486 Model 907 , Disk Part Noeea0025487 Model 907 , Ring Part Noeea0025488 Model 907 , Needle Bearing Part Noeea0025489 Model 907 , Planetary Pin Part Noeea0025490 Model 907 , Locking Pin Part Noeea0025491 Model 907 , Ring Gear Part Noeea0025492 Model 907 , Ring Gear Carrier Part Noeea0025493 Model 907 , Retainer Part Noeea0025494 Model 907 , Hexagon Screw Part Noeea0025495 Model 907 , O-Ring Part Noeea0025496 Model 907 , Differential And Carrier Assembly Part Noeea0025497 Model 907 , Drive Pinion Part Noeea0025498 Model 907 , Ring Gear Part Noeea0025499 Model 907 , Differential Housing Part Noeea0025500 Model 907 , Differential Spider Part Noeea0025502 Model 907 , Differential Side Gear Part Noeea0025503 Model 907 , Differential Pinion Part Noeea0025504 Model 907 , Bushing Part Noeea0025505 Model 907 , Hexagon Screw Part Noeea0025507 Model 907 , Tapered Roller Bearing Part Noeea0025508 Model 907 , Tapered Roller Bearing Part Noeea0025509 Model 907 , Differential Carrier Part Noeea0025510 Model 907 , Hexagon Screw Part Noeea0025511 Model 907 , Setting Ring Part Noeea0025512 Model 907 , Lock Plate Part Noeea0025513 Model 907 , Hexagon Screw Part Noeea0025515 Model 907 , Hexagon Screw Part Noeea0025516 Model 907 , Bolt Part Noeea0025517 Model 907 , Bolt Part Noeea0025518 Model 907 , Hexagon Nut Part Noeea0025519 Model 907 , Tapered Roller Bearing Part Noeea0025520 Model 907 , Bushing Part Noeea0025521 Model 907 , Tapered Roller Bearing Part Noeea0025522 Model 907 , Bearing Flange Part Noeea0025523 Model 907 , Cover Part Noeea0025524 Model 907 , Radial Seal Ring Part Noeea0025525 Model 907 , Hexagon Screw Part Noeea0025526 Model 907 , Compensation Plate Part Noeea0025527 Model 907 , Drive Flange Part Noeea0025528 Model 907 , Adjusting Nut Part Noeea0025529 Model 907 , Bearing Part Noeea0025530 Model 907 , Circlip Part Noeea0025531 Model 907 , Circlip Part Noeea0025532 Model 907 , Outer Disk Part Noeea0025534 Model 907 , Inner Disk Part Noeea0025535 Model 907 , Disk Part Noeea0025536 Model 907 , Disk Part Noeea0025537 Model 907 , O-Ring Part Noeea0025538 Model 907 , Disk Part Noeea0025539 Model 907 , Disk Part Noeea0025540 Model 907 , Ring Part Noeea0025541 Model 907 , Axle Bolt Part No917a060000019 Model 907 , Clamp Plate Part No917a020000008 Model 907 , Hex Head Bolt Part No370-0405 Model 907 , Spring Washer Part Nomdw12sa Model 907 , Hex Head Bolt Part No370-0310 Model 907 , Spring Washer Part Nomdw10sa Model 907 , Hex Nut Part No369-0110 Model 907 , Lock Wire (As Required) Part Nol400 Model 907 , Spring Washer Part Nomdw24sa Model 907 , Spacer Part Noeea0025806 Model 907 , Spacer Part Noeea0032217 Model 907 , Spacer Part Noeea0027058 Model 907 , Spacer Part Noeea0027059 Model 907 , Roll Back Cylinder Part No917b050000093 Model 907 , Tube S/A Part Noeea0027156 Model 907 , Piston Rod S/A Part Noeea0027157 Model 907 , Head End Cover Part Noeea0027158 Model 907 , Piston Part Noeea0027159 Model 907 , Circlip Part Noeea0025685 Model 907 , Sph. Bearing Part Noeea0025686 Model 907 , Grease Nipple With Cap Part Noeea0025669 Model 907 , Grub Screw Part Noeea0025670 Model 907 , Rod Wear Ring(*) Part Noeea0025688 Model 907 , Piston Seal-Glydring(*) Part Noeea0025689 Model 907 , Piston Rod O Ring(*) Part Noeea0025690 Model 907 , Piston Rod Backup Ring(*) Part Noeea0025691 Model 907 , Hec O Ring(*) Part Noeea0025692 Model 907 , Hec Backup Ring(*) Part Noeea0025693 Model 907 , Piston Wear Ring(*) Part Noeea0025694 Model 907 , Rod Seal-Bs Type(*) Part Noeea0025677 Model 907 , Rod Wiper-H860(*) Part Noeea0025695 Model 907 , Stop Tube O Ring(*) Part Noeea0025696 Model 907 , Step Seal (*) Part Noeea0025676 Model 907 , Steel Ball(*) Part Noeea0025679 Model 907 , Counter Balance Valve Part Noeea0027160 Model 907 , Grub Csrew Part Noeea0029180 Model 907 , Seal Kit (*) Marked Items Part Noeea0027161 Model 907 , Lift Cylinder Part No917b050000094 Model 907 , Tube S/A Part Noeea0027162 Model 907 , Piston Rod S/A Part Noeea0027163 Model 907 , Head End Cover Part Noeea0027164 Model 907 , Piston Part Noeea0027165 Model 907 , Circlip Part Noeea0025667 Model 907 , Sph Bearing Part Noeea0025668 Model 907 , Grease Nipple With Cap Part Noeea0025669 Model 907 , Grub Screw Part Noeea0025670 Model 907 , Piston Wear Ring (*) Part Noeea0025672 Model 907 , Piston Seal, Glydring (*) Part Noeea0025673 Model 907 , O-Ring, Piston Rod (*) Part Noeea0022809 Model 907 , Piston Rod Back Up Ring (*) Part Noeea0022810 Model 907 , Hec O Ring(*) Part Noeea0025674 Model 907 , Hec Backup Ring(*) Part Noeea0025675 Model 907 , Step Seal (*) Part Noeea0025676 Model 907 , Rod Seal-Bs Type(*) Part Noeea0025677 Model 907 , Rod Wiper-860(*) Part Noeea0025678 Model 907 , Steel Ball(*) Part Noeea0025679 Model 907 , Counter Balance Valve Part Noeea0027167 Model 907 , Seal Kit (*) Marked Items Part Noeea0027168 Model 907 , Rear Frame Part No907c020000099 Model 907 , Plate, Switch Mtg Part Noeea0002375 Model 907 , Coupling Part Nostdd017/015 Model 907 , Coupling (1Bsp) Part Nostdd017/16 Model 907 , Clamp, Half Part No912b060000098 Model 907 , Hex Head Bolt Part No370-0402 Model 907 , Plate Part Noeea0031318 Model 907 , Hex Nut Part No369-0116 Model 907 , Bracket Part No907a070000082 Model 907 , Plate Part Noeea0033367 Model 907 , Flat Washer Part Nomaw10ga Model 907 , Spring Washer Part Nomdw10sa Model 907 , Hex Head Bolt Part No370-0306 Model 907 , Threaded Boss Part Noeea0033366 Model 907 , Spring Washer Part Nomdw10sa Model 907 , Fuel Level Gauge Part No912b050000314 Model 907 , Plug Part No1027a050000003 Model 907 , Rear Axle Part No917b050000012 Model 907 , Axle Housing Part Noeea0025425 Model 907 , Breather Part Noeea0025426 Model 907 , Screw Plug Part Noeea0025427 Model 907 , Planetary Group Kit Part No907a070000086 Model 907 , Sealing Ring Part Noeea0025428 Model 907 , Screw Plug Part Noeea0025429 Model 907 , Sealing Ring Part Noeea0025430 Model 907 , Axle Shaft Part Noeea0025431 Model 907 , Axle Shaft Part Noeea0025432 Model 907 , Wheel Stud Part Noeea0025434 Model 907 , Hub Reduction Group Kit Part No907a070000087 Model 907 , Ring Part Noeea0025435 Model 907 , Radial Seal Ring Part Noeea0025436 Model 907 , Radial Seal Ring Part Noeea0025437 Model 907 , Tapered Roller Bearing Part Noeea0025438 Model 907 , Tapered Roller Bearing Part Noeea0025439 Model 907 , Ring Part Noeea0025440 Model 907 , Nut Part Noeea0025441 Model 907 , Hexagon Socket Screw Part Noeea0025442 Model 907 , O-Ring Part Noeea0025443 Model 907 , Sealing Ring Part Noeea0025444 Model 907 , Inner Disk Part Noeea0025445 Model 907 , Outer Disk Part Noeea0025446 Model 907 , Piston Part Noeea0025447 Model 907 , Gasket Part Noeea0025448 Model 907 , Gasket Part Noeea0025449 Model 907 , Brake Carrier Part Noeea0025450 Model 907 , Brake Housing Part Noeea0025451 Model 907 , O-Ring Part Noeea0025452 Model 907 , O-Ring Part Noeea0025453 Model 907 , O-Ring Part Noeea0025454 Model 907 , Hexagon Socket Screw Part Noeea0025455 Model 907 , Hexagon Socket Screw Part Noeea0025456 Model 907 , Face Seal Part Noeea0025457 Model 907 , Screw Plug Part Noeea0025458 Model 907 , Sealing Ring Part Noeea0025459 Model 907 , Bleeding Socket Part Noeea0025460 Model 907 , Sealing Ring Part Noeea0025461 Model 907 , Bleeder Valve Part Noeea0025462 Model 907 , Compression Spring Part Noeea0025463 Model 907 , Compression Spring Part Noeea0025464 Model 907 , Intermediate Piece Part Noeea0025465 Model 907 , Piston Guide Ring Part Noeea0025466 Model 907 , Warning Label Part Noeea0025467 Model 907 , O-Ring Part Noeea0025468 Model 907 , Thread Bushing Part Noeea0025469 Model 907 , O-Ring Part Noeea0025472 Model 907 , Cap Part Noeea0025473 Model 907 , Planetary Housing Part Noeea0025474 Model 907 , O-Ring Part Noeea0025475 Model 907 , Screw Plug Part Noeea0025476 Model 907 , Disk Part Noeea0025480 Model 907 , Hexagon Socket Screw Part Noeea0025481 Model 907 , Sun Gear Part Noeea0025482 Model 907 , Bushing Part Noeea0025483 Model 907 , Hexagon Socket Screw Part Noeea0025484 Model 907 , Ring Part Noeea0025485 Model 907 , Planetary Gear Part Noeea0025486 Model 907 , Disk Part Noeea0025487 Model 907 , Ring Part Noeea0025488 Model 907 , Needle Bearing Part Noeea0025489 Model 907 , Planetary Pin Part Noeea0025490 Model 907 , Locking Pin Part Noeea0025491 Model 907 , Ring Gear Part Noeea0025492 Model 907 , Ring Gear Carrier Part Noeea0025493 Model 907 , Retainer Part Noeea0025494 Model 907 , Hexagon Screw Part Noeea0025495 Model 907 , O-Ring Part Noeea0025496 Model 907 , Differential And Carrier Assembly Part Noeea0025470 Model 907 , Drive Pinion Part Noeea0025498 Model 907 , Ring Gear Part Noeea0025499 Model 907 , Differential Housing Part Noeea0025500 Model 907 , Differential Housing Part Noeea0025501 Model 907 , Hexagon Screw Part Noeea0025507 Model 907 , Tapered Roller Bearing Part Noeea0025508 Model 907 , Differential Carrier Part Noeea0025510 Model 907 , Hexagon Screw Part Noeea0025511 Model 907 , Setting Ring Part Noeea0025512 Model 907 , Lock Plate Part Noeea0025513 Model 907 , Hexagon Screw Part Noeea0025515 Model 907 , Hexagon Screw Part Noeea0025516 Model 907 , Bolt Part Noeea0025517 Model 907 , Bolt Part Noeea0025518 Model 907 , Hexagon Nut Part Noeea0025519 Model 907 , Tapered Roller Bearing Part Noeea0025520 Model 907 , Bushing Part Noeea0025521 Model 907 , Tapered Roller Bearing Part Noeea0025522 Model 907 , Bearing Flange Part Noeea0025523 Model 907 , Cover Part Noeea0025524 Model 907 , Radial Seal Ring Part Noeea0025525 Model 907 , Hexagon Screw Part Noeea0025526 Model 907 , Compensation Plate Part Noeea0025527 Model 907 , Drive Flange Part Noeea0025528 Model 907 , Adjusting Nut Part Noeea0025529 Model 907 , Bearing Part Noeea0025530 Model 907 , Circlip Part Noeea0025531 Model 907 , Circlip Part Noeea0025532 Model 907 , Nospin Differential Part Noeea0025533 Model 907 , O-Ring Part Noeea0025538 Model 907 , Disk Part Noeea0025539 Model 907 , Disk Part Noeea0025540 Model 907 , Credle Kit For Axle Part No907a070000084 Model 907 , Plate Part Noeea0025542 Model 907 , Ring Part Noeea0025543 Model 907 , Disk Part Noeea0025544 Model 907 , Disk Part Noeea0025545 Model 907 , Bushing Part Noeea0025546 Model 907 , Bracket Part Noeea0025547 Model 907 , Disk Part Noeea0025548 Model 907 , Plate Part Noeea0025549 Model 907 , Plate Part Noeea0025550 Model 907 , Plate Part Noeea0025551 Model 907 , Hexagon Screw Part Noeea0025552 Model 907 , Hexagon Screw Part Noeea0025553 Model 907 , Hexagon Screw Part Noeea0025554 Model 907 , O-Ring Part Noeea0025555 Model 907 , Grease Nipple Part Noeea0025556 Model 907 , Locking Pin Part Noeea0025557 Model 907 , Sunk Screw Part Noeea0025558 Model 907 , Hex Head Bolt Part No917a060000023 Model 907 , Spring Washer Part Nomdw20sa Model 907 , Dowelpin Part Nomkb30m40 Model 907 , Hex Head Bolt Part No917a060000024 Model 907 , Steering Cylinder Part No917b050000008 Model 907 , Tube S/A Part Noeea0025637 Model 907 , Piston Rod S/A Part Noeea0025638 Model 907 , Head End Cover Part Noeea0022798 Model 907 , Piston Part Noeea0025639 Model 907 , Circlip Part Noeea0022800 Model 907 , Spherical Bearing Part Noeea0022799 Model 907 , Grease Nipple With Cap Part Noeea0020796 Model 907 , Grub Screw Part Noeea0022801 Model 907 , Snap Ring Part Noeea0025634 Model 907 , Piston Wear Ring (*) Part Noeea0022803 Model 907 , Piston Seal (*) Part Noeea0022802 Model 907 , Piston Rod O Ring (*) Part Noeea0022804 Model 907 , Back Up Ring (*) Part Noeea0022805 Model 907 , O-Ring, Piston Rod (*) Part Noeea0022809 Model 907 , Hec B/U Ring(*) Part Noeea0025698 Model 907 , Rod Wear Ring (*) Part Noeea0022808 Model 907 , Rod Seal (*) Part Noeea0022807 Model 907 , Wiper(*) Part Noeea0025635 Model 907 , Seal Kit (*) Marked Items Part Noeea0025645 Model 907 , Spacer Part No907a020000046 Model 907 , Pin Part No917a060000016 Model 907 , Lock Plate Part No822a060000013 Model 907 , Hex Socket Head Cap Screw Part No370-2311 Model 907 , Pin Assy. Part No917a020000002 Model 907 , Pin Part No917a060000018 Model 907 , R. Bar Part Noeea0012035 Model 907 , Pin (F.F.-R.F.) Part No907b060000005 Model 907 , Clamp Half Part No912b060000115 Model 907 , Hex Head Bolt Part No370-0631 Model 907 , Hex Nut Part No369-0116 Model 907 , Spring Washer Part Nomdw16sa Model 907 , Hex Head Bolt Part No370-0236 Model 907 , Spring Washer Part Nomdw08sa Model 907 , Cover Part No811b020000150 Model 907 , Gasket Part No811b050000067 Model 907 , Tank Relief Cartridge Part No613m000001081 Model 907 , Bonded Seal Part Nosc011/013 Model 907 , Steel Ball Part Nogr6 Model 907 , Bonded Seal Part Nosc011/019 Model 907 , Drain Cock, Valve Part Nobp2rve Model 907 , Suction Strainer (40 Mesh) Part No625b050000122 Model 907 , Hex Bushing Part Nobp11bb10 Model 907 , Oil Level Window Part No241a000000284 Model 907 , Bonded Seal Part Nosc011/027 Model 907 , Grease Nipple Part Nobp1fg Model 907 , Lock Plate Part No912a020000551 Model 907 , Hex Head Bolt Part No370-0306 Model 907 , Flat Washer Part Nomaw08ga Model 907 , Lock Wire (As Required) Part Nol400 Model 907 , Plate Part Noeea0025704 Model 907 , Spacer Part Noeea0025803 Model 907 , Guard Part Noeea0028536 Model 907 , Hex Head Bolt Part No370-0237 Model 907 , Tank Breather Part No917a050000078 Model 907 , Clamp Plate Part Noeea0026327 Model 907 , Hex Head Bolt Part No370-0409 Model 907 , Hex Nut Part No369-0112 Model 907 , Spring Washer Part Nomdw12sa Model 907 , Flat Washer Part Nomaw12ga Model 907 , Seat- Hyd Suspension Part No907a050000093 Model 907 , Hex Head Bolt Part No370-0240 Model 907 , Fuel Level Guard Part No907a020000043 Model 907 , Bush Part Nombh100_120_50 Model 907 , Bush Part Nombh100_120_45 Model 907 , Bush Part Nombh100_120_61 Model 907 , Canopy Assembly Part No907a070000007 Model 907 , Threaded Boss Part No811a060000056 Model 907 , Threaded Boss Part No016a000099060 Model 907 , Eimco Logo Assy. Part No19wl020000262 Model 907 , Logo E (Big) Part No19wl020000263 Model 907 , Logo E Small Part No19wl020000264 Model 907 , Name Plate Part Noeeb0018997 Model 907 , Clamp Part Noeea0007780 Model 907 , Plate Part Noeea0027695 Model 907 , Beacon Mtg. Bkt. Part No910a020000114 Model 907 , Flashing Light Bracket Part Noeea0031660 Model 907 , Hex Head Bolt Part No370-0204 Model 907 , Spring Washer Part Nomdw06sa Model 907 , Hex Head Bolt Part No370-1013B Model 907 , Spring Washer Part Nomdw24sa Model 907 , Hex Head Bolt Part No370-1015 Model 907 , Hex Nut Part No369-0124 Model 907 , Hex Head Bolt Part No370-1009 Model 907 , Diesel Engine Part No907b050000005 Model 907 , Engine Bracket Part No907a020000059 Model 907 , Engine Bracket, Rh Part No907b020000060 Model 907 , Engine Bracket, Lh Part No907b020000061 Model 907 , Avm (Engine) Part No19wl050000865 Model 907 , Avm, Engine Part No910a050000025 Model 907 , Hex Head Bolt Part No370-0612 Model 907 , Hex Head Bolt Part No370-0623 Model 907 , Spacer Part Noeea0027233 Model 907 , Hex Head Bolt Part No370-1026 Model 907 , Hex Nut, Nyloc Part Nomt24ln Model 907 , Spring Washer Part Nomdw16sa Model 907 , Hex Nut Part No369-0124 Model 907 , Flat Washer Part Nomaw24ga Model 907 , Washer, Avm Part No907a020000068 Model 907 , Transmission Part No917b050000002 Model 907 , Pipe Plug Part Noeea0026623 Model 907 , Assembly-Conv Housing & Tube Part Noeea0022609 Model 907 , Sleeve Part Noeea0013072 Model 907 , Tube Slleve Part Noeea0005696 Model 907 , Sleeve Part Noeea0008045 Model 907 , Sleeve Lock Part Noeea0008046 Model 907 , Lock Washer Part Noeea0013073 Model 907 , Tube Clip Screw Part Noeea0005690 Model 907 , O Ring Part Noeea0013079 Model 907 , Spacer Ring Part Noeea0013080 Model 907 , Tube Assy. Part Noeea0013081 Model 907 , Lock Washer Part Noeea0005729 Model 907 , Screw, Cover Part Noeea0010946 Model 907 , Tube Clip Part Noeea0008041 Model 907 , Rev. Tube Assy. Part Noeea0011579 Model 907 , O Ring Part Noeea0013082 Model 907 , Lube Tube Assy. Part Noeea0011578 Model 907 , Tube Assy. Part Noeea0011580 Model 907 , Supply Tube Part Noeea0011583 Model 907 , Sleeve Part Noeea0013072 Model 907 , Tube Slleve Part Noeea0005696 Model 907 , Sleeve Part Noeea0008045 Model 907 , Sleeve Lock Part Noeea0008046 Model 907 , Lock Washer Part Noeea0013073 Model 907 , Tube Clip Screw Part Noeea0005690 Model 907 , Air Breather Part Noeea0005680 Model 907 , Elbow Part Noeea0011641 Model 907 , Breather Bushing Part Noeea0011556 Model 907 , Lock Washer Part Noeea0005685 Model 907 , Screw-Conv Hsg To Trans Case Part Noeea0026624 Model 907 , Lockwasher-Pump Mounting Screw Part Noeea0026625 Model 907 , Screw-Conv Hsg To Trans Case Part Noeea0026626 Model 907 , O Ring Part Noeea0013079 Model 907 , Spacer Ring Part Noeea0013080 Model 907 , Tube Assy. Part Noeea0013081 Model 907 , Lock Washer Part Noeea0005729 Model 907 , Screw, Cover Part Noeea0010946 Model 907 , Tube Clip Part Noeea0008041 Model 907 , Rev. Tube Assy. Part Noeea0011579 Model 907 , O Ring Part Noeea0013082 Model 907 , Lube Tube Assy. Part Noeea0011578 Model 907 , Tube Assy. Part Noeea0011580 Model 907 , Supply Tube Part Noeea0011583 Model 907 , Screw-Conv Hsg To Trans Case Part Noeea0026627 Model 907 , Gasket Part Noeea0008057 Model 907 , Pin Part Noeea0023186 Model 907 , Spacer Part Noeea0023187 Model 907 , Seal Part Noeea0005936 Model 907 , Cover-Converter Housing Front Part Noeea0026655 Model 907 , Screw Part Noeea0011557 Model 907 , Stud Nut Part Noeea0013069 Model 907 , Stud (Not Shown) Part Noeea0019387 Model 907 , Lock Washer Part Noeea0005729 Model 907 , Gasket Part Noeea0005917 Model 907 , Hose Fitting Part Noeea0013102 Model 907 , Hose Fitting Part Noeea0013103 Model 907 , Trans. Case & Tube Assy. Part Noeea0013750 Model 907 , Tube Assy. Part Noeea0013110 Model 907 , Clip Part Noeea0013109 Model 907 , Tube Slleve Part Noeea0005696 Model 907 , Pressure Tube Part Noeea0008060 Model 907 , Rivet Part Noeea0008072 Model 907 , Cap Screw Part Noeea0019350 Model 907 , Washer Part Noeea0013112 Model 907 , Oring, Suction Line Part Noeea0005966 Model 907 , Baffle, Oil Part Noeea0008073 Model 907 , Baffle, Oil Part Noeea0008074 Model 907 , O Ring Part Noeea0011654 Model 907 , Pressure Tube Part Noeea0011587 Model 907 , Tube Part Noeea0011588 Model 907 , Retainer Ring Part Noeea0008035 Model 907 , Oil Distributor Part Noeea0011609 Model 907 , Ball Part Noeea0019351 Model 907 , Tube Assy. Part Noeea0013110 Model 907 , Clip Part Noeea0013109 Model 907 , Tube Slleve Part Noeea0005696 Model 907 , Pressure Tube Part Noeea0008060 Model 907 , Rivet Part Noeea0008072 Model 907 , Cap Screw Part Noeea0019350 Model 907 , Washer Part Noeea0013112 Model 907 , O Ring Part Noeea0026628 Model 907 , Baffle, Oil Part Noeea0008073 Model 907 , Baffle, Oil Part Noeea0008074 Model 907 , O Ring Part Noeea0026629 Model 907 , Pressure Tube Part Noeea0011587 Model 907 , Tube Part Noeea0011588 Model 907 , Retainer Ring Part Noeea0008035 Model 907 , Oil Distributor Part Noeea0011609 Model 907 , Ball Part Noeea0019351 Model 907 , Dowel Pin Part Noeea0008061 Model 907 , O Ring Part Noeea0026630 Model 907 , Magnetic Drain Plug Part Noeea0005708 Model 907 , Plug-Oil Level/Plug-Lockup Port Part Noeea0026631 Model 907 , Screen Assembly Part Noeea0005688 Model 907 , Screen Assy. Gasket Part Noeea0005687 Model 907 , Cover Part Noeea0013751 Model 907 , Gasket Part Noeea0008075 Model 907 , Capscrew Part Noeea0026633 Model 907 , Lockwasher-Pump Mounting Screw Part Noeea0026625 Model 907 , Nut Part Noeea0026634 Model 907 , Stud Part Noeea0011561 Model 907 , Pipe Plug Part Noeea0005683 Model 907 , Capscrew Part Noeea0026635 Model 907 , Lockwasher Part Noeea0026636 Model 907 , Assy-Stator Support Sleeve Part Noeea0011616 Model 907 , Turbine Shaft Part Noeea0013121 Model 907 , Piston Ring Part Noeea0008293 Model 907 , Bearing Part Noeea0019389 Model 907 , Snap Ring Part Noeea0008050 Model 907 , Piston Ring Part Noeea0008278 Model 907 , Oil Baffle Part Noeea0011573 Model 907 , Seal Ring Part Noeea0011586 Model 907 , Ring, Oil Baffle Retaining Part Noeea0010858 Model 907 , Turbine Hub Part Noeea0013122 Model 907 , Snap Ring Part Noeea0008268 Model 907 , Reaction Member Part Noeea0013123 Model 907 , Spacer Part Noeea0011571 Model 907 , Snap Ring Part Noeea0013124 Model 907 , Bearing Part Noeea0013125 Model 907 , Impeller Hub Part Noeea0013126 Model 907 , O Ring Part Noeea0013127 Model 907 , Impeller Part Noeea0026638 Model 907 , Backing Ring Part Noeea0013129 Model 907 , Screw Part Noeea0013130 Model 907 , Turbine Part Noeea0011622 Model 907 , Screw Part Noeea0008272 Model 907 , Cap Screw Part Noeea0019390 Model 907 , Oring Part Noeea0005753 Model 907 , Impeller Cover Part Noeea0013132 Model 907 , Capscrew Part Noeea0026639 Model 907 , Lock Washer Part Noeea0005729 Model 907 , Bearing Part Noeea0013133 Model 907 , Bearing Washer Part Noeea0013134 Model 907 , Snap Ring Part Noeea0013135 Model 907 , O Ring Part Noeea0013136 Model 907 , Input Shaft Part Noeea0013137 Model 907 , Capscrew Part Noeea0026640 Model 907 , Shaft Bearing Part Noeea0011568 Model 907 , Lock Washer Part Noeea0005685 Model 907 , Screw Part Noeea0011642 Model 907 , Gear Part Noeea0013139 Model 907 , Bearing Support Part Noeea0011574 Model 907 , Bearing Ball Part Noeea0019391 Model 907 , Ring - Snap Part Noeea0019392 Model 907 , Ring-Span Part Noeea0008296 Model 907 , Gear-Imppeller Hub - 46T Part Noeea0013084 Model 907 , Gear- Pump Drive Idler 47T Part Noeea0019393 Model 907 , Support- Pump Drive Idler Part Noeea0019394 Model 907 , Bearing- Ball 6309 Part Noeea0019395 Model 907 , Snap-Ring-Internal Part Noeea0019376 Model 907 , Gear Clutch Driven 25T Part Noeea0026653 Model 907 , Gear-High Range 52T Part Noeea0011585 Model 907 , Gear-Drive Low 4Th. 26T Part Noeea0013737 Model 907 , Gear-2Nd 30T Part Noeea0011621 Model 907 , Reverse 2Nd Shaft Piston Ring Part Noeea0005807 Model 907 , Front Bearing Retaing Ring Part Noeea0005808 Model 907 , Washer Part Noeea0013140 Model 907 , End Plate Balend Plate Ball Part Noeea0013141 Model 907 , Front Bearing Part Noeea0013142 Model 907 , Bearing Part Noeea0023197 Model 907 , Retaninng Ring Part Noeea0023198 Model 907 , Baffle Ring Part Noeea0008085 Model 907 , Retainer Ring Part Noeea0008086 Model 907 , End Plate Part Noeea0013143 Model 907 , Clutch Outer Disc Part Noeea0008088 Model 907 , Inner Disc Part Noeea0013144 Model 907 , Assy. Clutch Piston & Seals Part Noeea0019377 Model 907 , Outer Seal Part Noeea0008091 Model 907 , Inner Seal Part Noeea0008092 Model 907 , Seal-Clutch Piston Metering Part Noeea0019354 Model 907 , Assy-Rev & 3Rd Shaft Part Noeea0023199 Model 907 , Seal-Clutch Piston -Outer Part Noeea0022170 Model 907 , Assy-Clutch Piston & Seals Part Noeea0022169 Model 907 , End Plate Part Noeea0013149 Model 907 , Retainer Spring Part Noeea0022171 Model 907 , Washer Assy. Part Noeea0013150 Model 907 , Snap Ring Retainer Part Noeea0008098 Model 907 , Spring Retainer Snap Ring Part Noeea0005820 Model 907 , Low Speed Gear Bearing Part Noeea0005826 Model 907 , Spring Retainer Part Noeea0008101 Model 907 , Return Spring Part Noeea0008102 Model 907 , Spring Retainer Part Noeea0008103 Model 907 , Bearing Part Noeea0008104 Model 907 , Snap Ring Part Noeea0008105 Model 907 , Spacer Part Noeea0008106 Model 907 , Shield Out Part Noeea0008107 Model 907 , Rear Bearing Part Noeea0013151 Model 907 , Retainer Ring Part Noeea0008109 Model 907 , Reverse 2Nd Shaft Piston Ring Part Noeea0005807 Model 907 , Front Bearing Retaing Ring Part Noeea0005808 Model 907 , Washer Part Noeea0013140 Model 907 , End Plate Balend Plate Ball Part Noeea0013141 Model 907 , Front Bearing Part Noeea0013142 Model 907 , Front Bearing Snap Ring Part Noeea0005809 Model 907 , Bearing Part Noeea0023197 Model 907 , Retaninng Ring Part Noeea0023198 Model 907 , Baffle Ring Part Noeea0008085 Model 907 , Low Speed Gear Bearing Part Noeea0005826 Model 907 , Spring Retainer Snap Ring Part Noeea0005820 Model 907 , Snap Ring Retainer Part Noeea0008098 Model 907 , Washer Assy. Part Noeea0013150 Model 907 , Retainer Spring Part Noeea0022171 Model 907 , Ring Retainer Part Noeea0013162 Model 907 , Sanp Ring Part Noeea0013163 Model 907 , Spring Retainer Part Noeea0008103 Model 907 , Return Spring Part Noeea0008102 Model 907 , Spring Retainer Part Noeea0008101 Model 907 , Retainer Ring Part Noeea0008086 Model 907 , End Plate Part Noeea0013143 Model 907 , Clutch Outer Disc Part Noeea0008088 Model 907 , Inner Disc Part Noeea0013144 Model 907 , Assy. Clutch Piston & Seals Part Noeea0019377 Model 907 , Outer Seal Part Noeea0008091 Model 907 , Inner Seal Part Noeea0008092 Model 907 , Seal-Clutch Piston Metering Part Noeea0019354 Model 907 , Assy.-Fwd & 2Nd Shaft, Hub, Drum & Plug Part Noeea0023243 Model 907 , Seal-Clutch Piston -Outer Part Noeea0022170 Model 907 , Assy-Clutch Piston & Seals Part Noeea0022169 Model 907 , End Plate Part Noeea0013149 Model 907 , Gear-Clutch Driven 27T Part Noeea0023193 Model 907 , Gear-2Nd 30T Part Noeea0011621 Model 907 , Assy-Low Shaft,Hub,Drum & Plug Part Noeea0019357 Model 907 , Assy-Low Hub & Drum Part Noeea0019358 Model 907 , O Ring Part Noeea0013178 Model 907 , Retaining Ring Part Noeea0013175 Model 907 , Shaft Part Noeea0013753 Model 907 , Plug Part Noeea0013179 Model 907 , Assy-Low Hub & Drum Part Noeea0019358 Model 907 , O Ring Part Noeea0013178 Model 907 , Retaining Ring Part Noeea0013175 Model 907 , Shaft Part Noeea0013753 Model 907 , Plug Part Noeea0013179 Model 907 , Seal-Clutch Piston Metering Part Noeea0019354 Model 907 , Assy-Clutch Piston & Seals Part Noeea0019359 Model 907 , Inner Seal Part Noeea0008092 Model 907 , Seal-Clutch Piston -Outer Part Noeea0022170 Model 907 , Clutch Inner Disc Part Noeea0008115 Model 907 , Clutch Outer Disc Part Noeea0008088 Model 907 , End Plate Part Noeea0008087 Model 907 , Retainer Ring Part Noeea0008086 Model 907 , Spring Part Noeea0013167 Model 907 , Retainer Spring Part Noeea0013168 Model 907 , Bearing Spacer Part Noeea0013170 Model 907 , Spring Retainer Part Noeea0008124 Model 907 , Snap Ring Part Noeea0008050 Model 907 , Ring Retainer Part Noeea0013169 Model 907 , Gear(54T) Part Noeea0013752 Model 907 , Bearing Assy. Part Noeea0013171 Model 907 , Piston Ring Part Noeea0008227 Model 907 , Pilot Bearing Part Noeea0008130 Model 907 , Bearing Cup Part Noeea0008156 Model 907 , Bearing Cone Part Noeea0013191 Model 907 , Cap Part Noeea0013756 Model 907 , Capscrew Part Noeea0026639 Model 907 , Lock Washer Part Noeea0005729 Model 907 , Lock Washer Part Noeea0005729 Model 907 , Pipe Plug Part Noeea0005683 Model 907 , O Ring Part Noeea0026644 Model 907 , O Ring Part Noeea0026645 Model 907 , Bearing Cup Part Noeea0014098 Model 907 , Bearing Cone Part Noeea0013173 Model 907 , Seal-Clutch Piston Metering Part Noeea0019354 Model 907 , Inner Seal Part Noeea0008092 Model 907 , Snap Ring Part Noeea0013135 Model 907 , Assy-4Th Hub & Drum Part Noeea0019360 Model 907 , Assy-Idler Shaft,Gear And Plugs Part Noeea0019361 Model 907 , Shaft And Bearing Assy. Part Noeea0013189 Model 907 , Bearing Lock Ball Part Noeea0008138 Model 907 , Locating Ring Part Noeea0008139 Model 907 , Washer Part Noeea0013764 Model 907 , Disc Hub Nut Part Noeea0013224 Model 907 , Gasket Part Noeea0008141 Model 907 , Cap Part Noeea0013765 Model 907 , Ber.Cap Stud Lock Washer Part Noeea0005861 Model 907 , Screw Part Noeea0013766 Model 907 , Outer Seal Part Noeea0008091 Model 907 , Assy-Clutch Piston & Seals Part Noeea0019359 Model 907 , Clutch Outer Disc Part Noeea0008088 Model 907 , Inner Disc Part Noeea0013144 Model 907 , End Plate Part Noeea0008087 Model 907 , Retainer Ring Part Noeea0008086 Model 907 , Spring Retainer Part Noeea0008101 Model 907 , Return Spring Part Noeea0008102 Model 907 , Spring Retainer Part Noeea0008103 Model 907 , Snap Ring Part Noeea0011575 Model 907 , Impeller Hub Gear Bearing Part Noeea0005738 Model 907 , Gear-4Th Clutch & Hub 23T Part Noeea0019363 Model 907 , Spacer Part Noeea0011595 Model 907 , Bearing Part Noeea0011566 Model 907 , Piston Ring Part Noeea0008224 Model 907 , Oil Seal Part Noeea0013190 Model 907 , Bearing Cap Part Noeea0008145 Model 907 , O Ring Part Noeea0026648 Model 907 , Bearing Cup Part Noeea0011629 Model 907 , Bearing Cone Part Noeea0013191 Model 907 , Gear Spacer Part Noeea0013192 Model 907 , Output Shaft Part Noeea0013193 Model 907 , Bearing Cup Part Noeea0008156 Model 907 , O Ring Part Noeea0026649 Model 907 , O Ring Part Noeea0026650 Model 907 , Ber.Cap Stud Lock Washer Part Noeea0005861 Model 907 , Capscrew Part Noeea0026651 Model 907 , Capscrew Part Noeea0026652 Model 907 , Gasket Part Noeea0011617 Model 907 , O Ring Part Noeea0013311 Model 907 , O Ring Part Noeea0005695 Model 907 , O Rong Part Noeea0013214 Model 907 , Stud Part Noeea0011577 Model 907 , Gasket Part Noeea0011637 Model 907 , Lock Washer Part Noeea0005685 Model 907 , Bearing Cap Stud Nut Part Noeea0005836 Model 907 , Pressure Regulator Part Noeea0013213 Model 907 , Plug-Oil Level/Plug-Lockup Port Part Noeea0026631 Model 907 , Valve Seat Part Noeea0011600 Model 907 , Spacer Part Noeea0011601 Model 907 , Safety Valve Plunger Part Noeea0013198 Model 907 , Valve Spring Part Noeea0008250 Model 907 , O Ring Part Noeea0026656 Model 907 , Valve Stop Part Noeea0011569 Model 907 , Roll Pin Part Noeea0011652 Model 907 , Valve Stop Part Noeea0008243 Model 907 , O Ring Part Noeea0026657 Model 907 , Valve Piston Part Noeea0011638 Model 907 , Valve Spring , Inner Part Noeea0008247 Model 907 , Valve Spring Outer Part Noeea0011613 Model 907 , Oil Seal Part Noeea0013212 Model 907 , Roll Pin Part Noeea0011602 Model 907 , Charging Pump & Cover Part Noeea0026646 Model 907 , Assyembly Charging Pump 20 Gpm Part Noeea0022635 Model 907 , Lockwasher Part Noeea0026658 Model 907 , Capscrew Part Noeea0026659 Model 907 , Gasket Part Noeea0013215 Model 907 , Pump Cover Part Noeea0013216 Model 907 , Gasket Part Noeea0013780 Model 907 , Capscrew Part Noeea0026683 Model 907 , Lock Washer Part Noeea0005729 Model 907 , Assembly-Control Valve Cover Part Noeea0026661 Model 907 , Plug Part Noeea0021168 Model 907 , Gasket Part Noeea0013780 Model 907 , Plug-Filler Part Noeea0021190 Model 907 , Spool Part Noeea0013781 Model 907 , Pin Part Noeea0013782 Model 907 , Accumulator Spring Inner Part Noeea0005908 Model 907 , Spring Part Noeea0013783 Model 907 , Spring Part Noeea0026662 Model 907 , Fitting Plug Part Noeea0026663 Model 907 , Spool Part Noeea0026664 Model 907 , Spring Part Noeea0026665 Model 907 , Pin Part Noeea0026666 Model 907 , Shuttle Valve-Bottom Part Noeea0013786 Model 907 , Ctrl Valve & Hsg. Assy. Part Noeea0013770 Model 907 , O Ring Part Noeea0026667 Model 907 , O Ring Part Noeea0026668 Model 907 , O Ring Part Noeea0026669 Model 907 , O Ring Part Noeea0026670 Model 907 , O Ring Part Noeea0026671 Model 907 , Assy-Spool Type Solenoid Cartrigde Part Noeea0026672 Model 907 , Fitting-Plug, O Ring Seal Part Noeea0026703 Model 907 , O Ring Part Noeea0026673 Model 907 , Spring Part Noeea0013768 Model 907 , Spool-Regulator Part Noeea0026674 Model 907 , Plug Part Noeea0013179 Model 907 , Cover-Solenoid Part Noeea0026676 Model 907 , Cover-Solenoid Part Noeea0026677 Model 907 , Capscrew Part Noeea0026678 Model 907 , Lock Washer Part Noeea0013073 Model 907 , Retainer-Wire Part Noeea0026679 Model 907 , Retainer Part Noeea0026680 Model 907 , Spacer-Wire Retainer Part Noeea0026681 Model 907 , Gasket Part Noeea0013767 Model 907 , Capscrew Part Noeea0026683 Model 907 , Lock Washer Part Noeea0005729 Model 907 , Flange Part Noeea0011972 Model 907 , O Ring, Flange Part Noeea0010959 Model 907 , Washer Part Noeea0011872 Model 907 , Nut Part Noeea0008317 Model 907 , Flange Part Noeea0013732 Model 907 , O Ring Part Noeea0013065 Model 907 , Washer Part Noeea0013064 Model 907 , Nut Part Noeea0008140 Model 907 , Pump Adaptor Part Noeea0026684 Model 907 , Gasket Part No4697203 Model 907 , Lockwasher Part Noeea0026636 Model 907 , Capscrew Part Noeea0026686 Model 907 , Pump Drive Sleeve & Snap Ring Part Noeea0019402 Model 907 , Pump Drive Hole Cover Part Noeea0019386 Model 907 , Snap Ring Part Noeea0013814 Model 907 , Snap Ring Part Noeea0008309 Model 907 , Gasket Part Noeea0011597 Model 907 , Adaptor-Pump Part Noeea0026688 Model 907 , Lock Washer Part Noeea0005685 Model 907 , Capscrew Part Noeea0026689 Model 907 , Lock Washer Part Noeea0005729 Model 907 , Capscrew Part Noeea0026690 Model 907 , Pump Drive Sleeve And Snap Ring Assembly Part Noeea0026691 Model 907 , Sleeve Pump Drive Part Noeea0026692 Model 907 , Snap Ring Part Noeea0008309 Model 907 , Kit-Connector, Wire & Seal Part Noeea0026654 Model 907 , Taps - Oil Fill Part Noeea0013091 Model 907 , Cab Control Part Noeea0025805 Model 907 , Duel Element Filter Assy. Part Noeea0026879 Model 907 , Filter Head Assy. Part Noeea0026880 Model 907 , Electrical Indicator Assy. Part Noeea0026881 Model 907 , Indicator Seal & Connector Nut Kit Part Noeea0026882 Model 907 , Filter Element Assy. Part Noeea0026790 Model 907 , Bracket Part No917a020000043 Model 907 , Bracket Part No917a020000044 Model 907 , Bracket Part No917a020000045 Model 907 , Bracket Part No917a020000046 Model 907 , Hex Head Bolt Part No917a060000022 Model 907 , Spring Washer Part Now12gf Model 907 , Dip Stick Part No912a050000080 Model 907 , Lock Wire (As Required) Part Nol400 Model 907 , Reducer(Bsp-Npt),M/M Part Nosc089/046 Model 907 , Elbow, 90 Degree M/F Part Nose012/026 Model 907 , Hose Assembly Part No623d02584/148 Model 907 , Bonded Seal Part Nosc011/024 Model 907 , Elbow, Street 90 Degree M/F Part Nobp6blb Model 907 , Pipe Part Noeea0026870 Model 907 , Pillow Block Bearing Part No917a050000016 Model 907 , Drive Line(Front) Part No912b050000206 Model 907 , Spider Assy. (7C) Part No912a050000208 Model 907 , Drive Line(Articulation) Part No912b050000218 Model 907 , Spider Assy. (7C) Part No912a050000208 Model 907 , Drive Line(Tr. To Rear Axle) Part No917b050000020 Model 907 , Hex Head Bolt Part Not8hg40 Model 907 , Spring Washer Part Now8gfb Model 907 , Hex Head Bolt Part No370-0612 Model 907 , Hex Nut Part No369-0116 Model 907 , Spring Washer Part Nomdw16sa Model 907 , Flat Washer Part Nomaw16ga Model 907 , Hex Head Bolt Part No370-0815 Model 907 , Hex Nut Part No369-0120 Model 907 , Spring Washer Part Nomdw20sa Model 907 , Hex Head Bolt Part Not6hg32 Model 907 , Spring Washer Part Now6gf Model 907 , Upbox Part No917b050000090 Model 907 , Radial Seal Ring Part Noeea0027541 Model 907 , Drive Flange Part Noeea0027542 Model 907 , Hexagon Screw Part Noeea0027543 Model 907 , Disk Part Noeea0027544 Model 907 , Disk Part Noeea0027545 Model 907 , Housing Part Noeea0027546 Model 907 , Screw Plug Part Noeea0027547 Model 907 , Sealing Ring Part Noeea0027548 Model 907 , Screw Plug Part Noeea0027549 Model 907 , Breather Part Noeea0027550 Model 907 , Plate Part Noeea0027551 Model 907 , Hexagon Socket Screw Part Noeea0027552 Model 907 , Sleeve Part Noeea0027553 Model 907 , Hexagon Screw Part Noeea0027554 Model 907 , Radial Seal Ring Part Noeea0027555 Model 907 , Angle Piece Part Noeea0027556 Model 907 , Cover Part Noeea0027557 Model 907 , Gear Wheel Part Noeea0027558 Model 907 , Pinion Part Noeea0027559 Model 907 , Shaft Part Noeea0027560 Model 907 , Hexagon Socket Screw Part Noeea0027561 Model 907 , Bearing Part Noeea0027562 Model 907 , Bearing Part Noeea0027563 Model 907 , Cover Part Noeea0027564 Model 907 , Hexagon Screw Part Noeea0027565 Model 907 , Pinion Part Noeea0027566 Model 907 , Grooved Ball Bearing Part Noeea0027567 Model 907 , Grooved Ball Bearing Part Noeea0027568 Model 907 , Flange Part Noeea0027569 Model 907 , Hexagon Screw Part Noeea0027570 Model 907 , Cover Part Noeea0027571 Model 907 , Hexagon Screw Part Noeea0027572 Model 907 , Driver Part Noeea0027573 Model 907 , Pipe Part Noeea0027574 Model 907 , Sealing Ring Part Noeea0027575 Model 907 , O-Ring Part Noeea0027576 Model 907 , O-Ring Part Noeea0027577 Model 907 , Coupling Part No917b050000118 Model 907 , Adaptor Plate Part Noeea0026883 Model 907 , Stud Part No907a020000017 Model 907 , Hex Nut Part No369-0110 Model 907 , Flat Washer Part Nomaw10ga Model 907 , Drive Line Part No917b050000092 Model 907 , Spider Assy. - 6C Part No907a050000050 Model 907 , Spring Washer Part Nomdw10sa Model 907 , Hex Head Bolt Part No370-0310 Model 907 , Spacer Part No912a060000178 Model 907 , Wheel Assy. Part No907b070000067 Model 907 , Wheel Rim Part No917b050000009 Model 907 , Sleek Tyre 17.5 X R25 Part No907a050000091 Model 907 , Valve, Wheel Rim Part No907a050000075 Model 907 , Steering Hydraulic Group Part No907b070000029 Model 907 , Feeder Unit Block Part No19wl050000019 Model 907 , Accumulator Part No12wl050000999 Model 907 , Relief Valve Assy. Part No625b050000064 Model 907 , Relief Cartridge Part Noeea0008997 Model 907 , Seal Kit-Relief Valve,(*)Marked Items Part Noeea0009001 Model 907 , Accumulator (4-Ltr) Part No811a050000191 Model 907 , Seal Kit For (*) Marked Items Part Noeea0019109 Model 907 , Sealing Ring Part Noeea0022384 Model 907 , O-Ring Part Noeea0022385 Model 907 , Pilot Valve Part No910b050000055 Model 907 , 2 Way Poppet Valve(Nc) Part No907a050000001 Model 907 , Gasket Part No912a050000229 Model 907 , Accumulator Charge Valve Part No912b050000309 Model 907 , Repair Kit Part Noeea0018821 Model 907 , Suction Flange Part No917a020000061 Model 907 , Suction Flange Part No917a020000062 Model 907 , Feeder Block Mounting Bracket Part No917a020000068 Model 907 , Check Valve Part No907a050000004 Model 907 , Steering Contrl Valve Part No917b050000115 Model 907 , Hydraulic Pump(Steering And Brake) Part No917b050000017 Model 907 , M14 Screw Part Noeea0026292 Model 907 , M14 Nut Part Noeea0026293 Model 907 , Oil Seal Part Noeea0011535 Model 907 , Thr. Plate Part Noeea0026294 Model 907 , Seal. Chann Part Noeea0026295 Model 907 , Seal. Bk-Up Part Noeea0026296 Model 907 , Seal Sect. Part Noeea0026297 Model 907 , Plug Part Noeea0022648 Model 907 , Seal Kit Part Noeea0026838 Model 907 , Split Flange Half (Code 61) Part Nod10a010000032 Model 907 , Special Fitting Part No907a050000067 Model 907 , Manifold Part No907b020000051 Model 907 , Bracket, Acc. Charge Vlv Part No912a020000652 Model 907 , Pipe Bend (90 Degree) Part No917a050000058 Model 907 , Clamp Part Noeea0019155 Model 907 , Hose Clip Part Nop105phb Model 907 , O Ring Part Nos2712 Model 907 , O Ring Part Nos2803 Model 907 , O Ring 32.92X3.53-N-Nbr90 Part No341-5030 Model 907 , Hose Assy. Part No907a050000065 Model 907 , Hose Assy. Part No907a050000066 Model 907 , Hyd.Hose Part Nostdb025/004 Model 907 , Hyd.Hose Part No625a050000113 Model 907 , Hose Assy. Part Nostdd026/039 Model 907 , Hose Assy. Part Nostdd026/084 Model 907 , Hose Assy. Part Nostdd026/112 Model 907 , Hose Assy. Part Nostdd026/301 Model 907 , Hose Assy. Part Nostdd026/309 Model 907 , Hose Assy. Part Nostdd026/310 Model 907 , Hose Assy. Part Nostdd026/317 Model 907 , Hose Assy. Part Nostdd026/321 Model 907 , Hose Assy. Part Nostdd026/323 Model 907 , Hose Assy. Part Nostdd026/327 Model 907 , Hose Assy. Part Nostdd026/334 Model 907 , Hose Assy. Part Nostdd033/033 Model 907 , Hose Assy. Part Nostdd033/037 Model 907 , Hose Assy. Part Nostdd033/094 Model 907 , Hex Bushing Part Nobp8bb7 Model 907 , Bonded Seal Part Nosc011/009 Model 907 , Bonded Seal Part Nosc011/013 Model 907 , Bonded Seal Part Nosc011/016 Model 907 , Bonded Seal Part Nosc011/019 Model 907 , Bonded Seal Part Nosc011/024 Model 907 , Bonded Seal Part Nosc011/027 Model 907 , Straight Adaptor Part Nose024/201 Model 907 , Straight Adaptor Part Nose024/202 Model 907 , Straight Adaptor Part Nose024/203 Model 907 , Straight Adaptor Part Nose024/208 Model 907 , Straight Adaptor Part Nose024/209 Model 907 , Straight Adaptor Part Nose024/211 Model 907 , Straight Adaptor Part Nose024/212 Model 907 , Straight Adaptor Part Nose024/217 Model 907 , Straight Adaptor Part Nose024/218 Model 907 , Straight Adaptor Part Nose024/219 Model 907 , Straight Adaptor Part Nose024/429 Model 907 , Straight Adaptor Part Nose024/430 Model 907 , Swivel Adaptor (F/F) Part Nose024/431 Model 907 , Adaptor Part Nose024/454 Model 907 , Tee Part Novu10f10e01ds Model 907 , Swivel Nut Elbow Part Novu10f10e21bs Model 907 , Elbow 45 Deg Part Novu10f10e21cs Model 907 , Reducer Part Novu10f16e16as Model 907 , St. Adaptor Part Novu10f8e16as Model 907 , St. Adaptor Part Novu12f12e16as Model 907 , Swivel Elbow,90 Deg. Part Novu12f12e21bs Model 907 , Adaptor Part Novu12f12e33ds Model 907 , Adaptor Part Novu12f16e16as Model 907 , Elbow 90 Degree Part Novu16f16e20bs Model 907 , Swivel Nut Elbow Part Novu16f16e21bs Model 907 , Straight Adaptor Part Novu6f6e16as Model 907 , Swivel Nut Elbow Part Novu6f6e21bs Model 907 , Swivel, Tee Part Novu6f6e25ds Model 907 , Swivel Nut Branch Tee Part Novu6f6e33ds Model 907 , Elbow 90 Degree Part Novu6f8e20bs Model 907 , Elbow 90 Degree Part Novu8f8e21bs Model 907 , Hex Nut Part No369-0106 Model 907 , Hex Nut Part No369-0110 Model 907 , Hex Nut Part No369-0112 Model 907 , Hex Head Bolt Part No370-0206 Model 907 , Hex Head Bolt Part No370-0237 Model 907 , Hex Head Bolt Part No370-0304 Model 907 , Hex Head Bolt Part No370-0306 Model 907 , Hex Head Bolt Part No370-0312 Model 907 , Hex Head Bolt Part No370-0402 Model 907 , Hex Head Bolt Part No370-0403 Model 907 , Hex Socket Head Cap Screw Part No370-2411 Model 907 , Threaded Boss (M12x15lg) Part Noeea0016795 Model 907 , Flat Washer Part Nomaw06ga Model 907 , Flat Washer Part Nomaw08ga Model 907 , Flat Washer Part Nomaw10ga Model 907 , Flat Washer Part Nomaw12ga Model 907 , Spring Washer Part Nomdw06sa Model 907 , Spring Washer Part Nomdw08sa Model 907 , Spring Washer Part Nomdw10sa Model 907 , Spring Washer Part Nomdw12sa Model 907 , Hex Head Bolt Part Not6gg12 Model 907 , Hex Head Bolt Part Not8gg28 Model 907 , Spring Washer Part Now8gf Model 907 , Pressure Filter Part No811a050000182 Model 907 , Filter Element Part Noeea0018438 Model 907 , Filter Mounting Bracket Part No917a020000087 Model 907 , Hex Head Bolt Part No370-0420 Model 907 , Bracket, Pilot Valve Part No910a020000187 Model 907 , Bracket Part Noeea0025607 Model 907 , Plate Part Noeea0025606 Model 907 , Hex Nut Part Nomt28mgg Model 907 , Hose Assy. Part Nostdd033/114 Model 907 , Boss Part Noeea0001567 Model 907 , Service Hydraulic Group Part No907b070000030 Model 907 , Manifold Block Part No910a050000019 Model 907 , Check Valve Part Noeea0030269 Model 907 , Seal Kit, Check Valve Part Noeea0030272 Model 907 , Direction Valve Part Noeea0030270 Model 907 , Seal Kit, Direction Valve Part Noeea0030273 Model 907 , Solenoid Valve Part Noeea0030271 Model 907 , Seal Kit, Solenoid Valve Part Noeea0030274 Model 907 , 3/2 Way Valve Part No19wl050000655 Model 907 , Check Valve Part No625a050000111 Model 907 , Gasket Part No912a050000229 Model 907 , Hydraulic Hand Pump Part No611b050000326 Model 907 , Hydraulic Pump(Steering And Brake) Part No917b050000017 Model 907 , M14 Screw Part Noeea0026292 Model 907 , M14 Nut Part Noeea0026293 Model 907 , Oil Seal Part Noeea0011535 Model 907 , Thr. Plate Part Noeea0026294 Model 907 , Seal. Chann Part Noeea0026295 Model 907 , Seal. Bk-Up Part Noeea0026296 Model 907 , Seal Sect. Part Noeea0026297 Model 907 , Plug Part Noeea0022648 Model 907 , Seal Kit Part Noeea0026838 Model 907 , Relief Valve Assy. Part No625b050000064 Model 907 , Relief Cartridge Part Noeea0008997 Model 907 , Seal Kit-Relief Valve,(*)Marked Items Part Noeea0009001 Model 907 , Return Filter Part No611a050000018 Model 907 , Filter Element Part Noeea0003479 Model 907 , Container Part Noeea0000029 Model 907 , O Ring (*) Part Noeea0000031 Model 907 , O Ring (*) Part Noeea0000032 Model 907 , O Ring (*) Part Noeea0000033 Model 907 , Hex Socket Head Cap Screw Part No370-2409 Model 907 , Sealkit,(*)Marked Items Part Noeea0001034 Model 907 , Service Control Vale Part No907b050000089 Model 907 , T-Bolt Clamp Part No12wl050000817 Model 907 , Suction Flange Part No917a020000064 Model 907 , Suction Flange Part No917a020000063 Model 907 , Stand Pipe Part No803a000000337 Model 907 , Split Flange Half (Code 61) Part Nod10a010000032 Model 907 , Quick Release Coupling Part No625a050000011 Model 907 , Bspp Socket Part No625a050000106 Model 907 , Bspp Plug Part No625a050000107 Model 907 , Plug For Qrc Part No625a060000008 Model 907 , Pipe Bend (90 Degree) Part No917a050000058 Model 907 , Manifold Part No907b020000051 Model 907 , Hose Clip Part Nop105phb Model 907 , Flanged Pipe Part Noeea0025628 Model 907 , Elbow Part Nod06a050000150 Model 907 , O Ring 32.92X3.53-N-Nbr90 Part No341-5030 Model 907 , O Ring Part Nos2816 Model 907 , O Ring Part Nos2803 Model 907 , Hose Assy. Part No917a050000068 Model 907 , Hose Assy. Part Nostdd026/039 Model 907 , Hose Assy. Part Nostdd026/289 Model 907 , Hose Assy. Part Nostdd026/295 Model 907 , Hose Assy. Part Nostdd026/301 Model 907 , Hose Assy. Part Nostdd026/310 Model 907 , Hose Assy. Part Nostdd026/315 Model 907 , Hose Assy. Part Nostdd026/380 Model 907 , Hose Assy. Part Nostdd032/030 Model 907 , Hose Assy. Part Nostdd032/042 Model 907 , Hose Assy. Part Nostdd032/047 Model 907 , Hose Assy. Part Nostdd033/014 Model 907 , Hose Assy. Part Nostdd033/106 Model 907 , Hyd. Hose Part Nostdb025/013 Model 907 , Hyd.Hose (51 Mm) Part No625a050000113 Model 907 , Hyd. Hose Part Nostdb025/014 Model 907 , Hyd.Hose (51 Mm) Part No625a050000113 Model 907 , Hyd.Hose Part Nostdb025/004 Model 907 , Hyd.Hose (51 Mm) Part No625a050000113 Model 907 , Hydraulic Hose Part No19wl050000562 Model 907 , Adaptor Part Nod06a050000132 Model 907 , Adaptor Part Novu12f12e33ds Model 907 , Adaptor Part Novu12f16e16as Model 907 , Adaptor Part Novu16f16e16asb Model 907 , Adaptor Part Novu8f8e21cs Model 907 , Adaptor (Unf To Jic) Part Novu20f20e20asa Model 907 , Elbow 45 Deg. Part Novu12f12e21cs Model 907 , Elbow 90 Degree Part Novu8f8e21bs Model 907 , Elbow, 90 Degree M/F Part Nose012/022B Model 907 , Elbow, 90 Degree M/F Part Nose012/026 Model 907 , Elbow,Std.90 Degree F/F Part Nobp8bl Model 907 , Gauge Adaptor Part Noeea0003750 Model 907 , Reducer, M/M Part Nose012/096 Model 907 , Reducer, M/M Part Nose012/097 Model 907 , Special Elbow Part Noeea0028571 Model 907 , Special Elbow Part Noeea0017326 Model 907 , St. Adaptor Part Nose024/081 Model 907 , St.Swivel Adaptor M/F Part Nose012/062 Model 907 , Straight Adaptor Part Nose024/201 Model 907 , Straight Adaptor Part Nose024/202 Model 907 , Straight Adaptor Part Nose024/203 Model 907 , Straight Adaptor Part Nose024/206 Model 907 , Straight Adaptor Part Nose024/208 Model 907 , Straight Adaptor Part Nose024/209 Model 907 , Straight Adaptor Part Nose024/211 Model 907 , Straight Adaptor Part Nose024/217 Model 907 , Straight Adaptor Part Nose024/427 Model 907 , Straight Adaptor Part Novu6f6e16as Model 907 , Straight Adaptor M/M Part Nose024/207 Model 907 , Straight Adaptor, M/M Part Nose012/085 Model 907 , Swivel Adaptor (F/F) Part Nose024/431 Model 907 , Swivel Elbow,90 Deg. Part Novu12f12e21bs Model 907 , Swivel Nut Branch Tee Part Novu6f6e33ds Model 907 , Swivel Nut Elbow Part Novu16f16e21bs Model 907 , Swivel Nut Elbow Part Novu6f6e21bs Model 907 , Swivel, Tee Part Novu6f6e25ds Model 907 , Bonded Seal Part Nosc011/009 Model 907 , Bonded Seal Part Nosc011/016 Model 907 , Bonded Seal Part Nosc011/019 Model 907 , Bonded Seal Part Nosc011/024 Model 907 , Bonded Seal Part Nosc011/027 Model 907 , Flat Washer Part Nomaw12ga Model 907 , Hex Bushing Part Nobp9bb8 Model 907 , Hex Head Bolt Part No370-0308 Model 907 , Hex Head Bolt Part No370-0312 Model 907 , Hex Head Bolt Part No370-0402 Model 907 , Hex Head Bolt Part No370-0405 Model 907 , Hex Head Bolt Part No370-0420 Model 907 , Hex Head Bolt Part No370-0607 Model 907 , Hex Head Bolt Part Not8gg28 Model 907 , Hex Head Plug (Bsp) Part Nosc036/002 Model 907 , Hex Head Plug (Bsp) Part Nosc036/004 Model 907 , Hex Nut Part No369-0110 Model 907 , Hex Socket Head Cap Screw Part No370-2411 Model 907 , Hex. Head Plug (1-5/8Unf-2A) Part Nosc036/056 Model 907 , Spring Washer Part Nomdw10sa Model 907 , Spring Washer Part Nomdw12sa Model 907 , Spring Washer Part Nomdw16sa Model 907 , Spring Washer Part Now8gf Model 907 , Hose Sleeve Part No611a050000139 Model 907 , Hex Head Bolt Part No370-0306 Model 907 , Flat Washer Part Nomaw10ga Model 907 , Manifold Block Part No910b050000054 Model 907 , Pressure Filter Part No811a050000182 Model 907 , Filter Element Part Noeea0018438 Model 907 , Filter Mounting Bracket Part No917a020000087 Model 907 , Hose Assy. Part Nostdd033/114 Model 907 , Hex Head Bolt Part No370-0304 Model 907 , Boss Part Noeea0001567 Model 907 , Hose Assy. Part Nostdd033/037 Model 907 , Hose Assy. Part Nostdd026/024 Model 907 , Hose Assy. Part Nostdd033/024 Model 907 , Hose Assembly Part No623d02584/182 Model 907 , Hose Assembly Part No623d02584/201 Model 907 , Hose Assy. Part Nostdd026/323 Model 907 , Hose Assy. Part Nostdd026/092 Model 907 , Hose Assy. Part Nostdd026/047 Model 907 , Hose Assy. Part Nostdd026/317 Model 907 , Hose Assy. Part Nostdd026/328 Model 907 , Hose Assembly Part No623d02584/753 Model 907 , Hose Assembly Part No623d02584/756 Model 907 , Speical Fitting Part Noeea0029310 Model 907 , Threaded Boss Part Noeea0027253 Model 907 , Swivel Elbow,90 Deg. Part Novu12f12e21bs Model 907 , Reducer, M/M Part Nose012/095 Model 907 , Bonded Seal Part Nosc011/013 Model 907 , Hex Head Plug (Bsp) Part Nosc036/003 Model 907 , Threaded Boss (M12x15lg) Part Noeea0016795 Model 907 , Straight Adaptor Part Nose024/219 Model 907 , Swivel Nut Elbow Part Novu10f10e21bs Model 907 , Hose Assy. Part No907a050000065 Model 907 , Straight Adaptor Part Novu10f10e01as Model 907 , St. Adaptor Part Nose024/210 Model 907 , Straight Adaptor Part Nose024/430 Model 907 , St.Swivel Adaptor M/F Part Nose012/066 Model 907 , Reducer, M/M Part Nose012/101 Model 907 , Straight Adaptor Part Nose024/212 Model 907 , Hose Assy. Part Nostdd026/314 Model 907 , Hose Assy. Part Nostdd026/025 Model 907 , Hose Assy Part Nostdd033/023 Model 907 , Hose Assy. Part Nostdd033/039 Model 907 , Hose Assy. Part Nostdd033/031 Model 907 , Special Fitting Part Noeea0029315 Model 907 , Hydraulic Pump Part No910b050000063 Model 907 , Hydraulic Pump, Brake Oil Part No907b050000025 Model 907 , Screw Part Noeea0027587 Model 907 , Washer Part Noeea0027588 Model 907 , Seal Part Noeea0027589 Model 907 , Standard Seal Part Noeea0027590 Model 907 , Shaft Seal Part Noeea0027591 Model 907 , Ring Part Noeea0027592 Model 907 , Anti Extrusion Part Noeea0027593 Model 907 , Dowel Pin Part Noeea0027594 Model 907 , Seal Kit Part Noeea0029260 Model 907 , Pressure Filter Part No811a050000182 Model 907 , Filter Element Part Noeea0018438 Model 907 , Relief Valve Assy. Part No625b050000064 Model 907 , Relief Cartridge Part Noeea0008997 Model 907 , Seal Kit-Relief Valve,(*)Marked Items Part Noeea0009001 Model 907 , Valve, Check 50 Psi Crack Part No117439 Model 907 , Accumulator (4-Ltr) Part No811a050000191 Model 907 , Seal Kit For (*) Marked Items Part Noeea0019109 Model 907 , Sealing Ring Part Noeea0022384 Model 907 , O-Ring Part Noeea0022385 Model 907 , Brake Valve Part No917b050000013 Model 907 , Repair Kit, Brake Valve Part Noeea0025375 Model 907 , 3 Way Dcv Part No811a050000158 Model 907 , 3/2 Way Valve Part No19wl050000655 Model 907 , Gasket Part No907a050000047 Model 907 , Gasket Part No912a050000229 Model 907 , Suction Flanged Part No910a020000228 Model 907 , Stand Pipe Part No625a060000092 Model 907 , Stand Pipe (1 1/4 Bspt) Part No621a000000202 Model 907 , Special Elbow Part Noeea0012523 Model 907 , Elbow, 90 Degree M/F Part Nose012/024 Model 907 , Half Coupling Part Nobp2fka Model 907 , Special Elbow Part No912a020000477 Model 907 , Return Manifold Part No822b020000066 Model 907 , Half Coupling Part Nobp7fka Model 907 , Half Coupling Part Nobp8fka Model 907 , Coupling Part Nostdd017/014 Model 907 , Coupling Part Nostdd017/015 Model 907 , Quick Release Coupling Part No912a050000201 Model 907 , Plug Part No912a060000188 Model 907 , Manifold Block Part No917b060000025 Model 907 , Manifold Block Part No917b060000021 Model 907 , Gauge Panel Assy. Part No907a070000028 Model 907 , Bracket For Gauge Isolator Part No907b020000064 Model 907 , Pres.Gauge Isolator Valve Part No811a050000013 Model 907 , Drive Oil Pressure Gauge Part No813b000000182 Model 907 , Oil Pressure Gauge Part No917b050000080 Model 907 , Hex Nut Part No369-0110 Model 907 , Hex Head Bolt Part Nostdb035-10-25 Model 907 , Spring Washer Part Nomdw10sa Model 907 , Hex Socket Head Cap Screw Part No370-2141 Model 907 , Hex Nut Part No369-0105 Model 907 , Spring Washer Part Nomdw05sa Model 907 , Gauge Adaptor Part No811a060000088 Model 907 , St.Swivel Adaptor M/F Part Nose012/062 Model 907 , Filter Mounting Bracket Part No917a020000087 Model 907 , Bulkhead Bar Weldment Part No917a020000072 Model 907 , Plate Part Noeea0025411 Model 907 , Tee Adaptor Part No105635 Model 907 , Tee Adaptor Part No102273 Model 907 , O Ring Part Nos3308 Model 907 , Clamp Part Noeea0019155 Model 907 , Gauge Adaptor Part Noeea0009296 Model 907 , Hose Assembly Part No623d02584/333 Model 907 , Hose Part No625a00397/026 Model 907 , Hyd.Hose (38 Mm) Part Noeea0009461 Model 907 , Hose Clamp Part Nop9phb Model 907 , Hose Assy. Part Nostdd026/010 Model 907 , Hose Assy. Part Nostdd026/019 Model 907 , Hose Assy. Part Nostdd026/024 Model 907 , Hose Assy. Part Nostdd026/031 Model 907 , Hose Assy. Part Nostdd026/034 Model 907 , Hose Assy. Part Nostdd026/035 Model 907 , Hose Assy. Part Nostdd026/045 Model 907 , Hose Assy. Part Nostdd026/047 Model 907 , Hose Assy. Part Nostdd026/051 Model 907 , Hose Assy. Part Nostdd026/065 Model 907 , Hose Assy. Part Nostdd026/085 Model 907 , Hose Assy. Part Nostdd026/092 Model 907 , Hose Assy. Part Nostdd026/108 Model 907 , Hose Assy. Part Nostdd026/123 Model 907 , Hose Assy. Part Nostdd026/182 Model 907 , Hose Assy. Part Nostdd026/190 Model 907 , Hose Assy. Part Nostdd026/283 Model 907 , Hose Assy. Part Nostdd026/285 Model 907 , Hose Assy. Part Nostdd026/295 Model 907 , Hose Assy. Part Nostdd026/301 Model 907 , Hose Assy. Part Nostdd026/309 Model 907 , Hose Assy. Part Nostdd026/314 Model 907 , Hose Assy. Part Nostdd026/315 Model 907 , Hose Assy. Part Nostdd026/317 Model 907 , Hose Assy. Part Nostdd026/328 Model 907 , Hose Assy. Part Nostdd026/335 Model 907 , Hose Assy. Part Nostdd033/014 Model 907 , Hose Assy. Part Nostdd033/041 Model 907 , Hoseassy. Part Nostdd033/047 Model 907 , Adaptor Part No907a050000039 Model 907 , St. Adaptor (Metric To Jic) Part No917a050000060 Model 907 , St. Adaptor(Metric To Jic) Part No917a050000061 Model 907 , St. Adaptor(Metric To Jic) Part No917a050000062 Model 907 , Fitting Part Noeea0004895 Model 907 , Bonded Seal Part Nosc011/009 Model 907 , Bonded Seal Part Nosc011/016 Model 907 , Bonded Seal Part Nosc011/019 Model 907 , Bonded Seal Part Nosc011/024 Model 907 , Bonded Seal Part Nosc011/027 Model 907 , Elbow, 90 Degree M/F Part Nose012/024 Model 907 , Elbow, 90 Degree M/F Part Nose012/026 Model 907 , St.Swivel Adst.Swivel Adaptor F/F Part Nose012/044 Model 907 , St.Swivel Adst.Swivel Adaptor F/F Part Nose012/046 Model 907 , St.Swivel Adaptor M/F Part Nose012/066 Model 907 , St.Swivel Adaptor M/F Part Nose012/067 Model 907 , Straight Adaptor, M/M Part Nose012/082 Model 907 , Straight Adaptor, M/M Part Nose012/085 Model 907 , Straight Adaptor, M/M Part Nose012/086 Model 907 , Reducer, M/M Part Nose012/100 Model 907 , Reducer, M/M Part Nose012/101 Model 907 , St. Adaptor Part Nose024/008 Model 907 , St. Adaptor Part Nose024/009 Model 907 , St. Adaptor Part Nose024/078 Model 907 , Straight Adaptor Part Nose024/201 Model 907 , Straight Adaptor Part Nose024/202 Model 907 , Straight Adaptor Part Nose024/203 Model 907 , Straight Adaptor Part Nose024/208 Model 907 , Straight Adaptor Part Nose024/211 Model 907 , Straight Adaptor Part Nose024/214 Model 907 , Straight Adaptor Part Nose024/217 Model 907 , Straight Adaptor Part Nose024/218 Model 907 , Straight Adaptor Part Nose024/219 Model 907 , Straight Adaptor Part Nose024/220 Model 907 , Straight Adaptor Part Nose024/287 Model 907 , Tee, M/M/F Part Nose024/330 Model 907 , Straight Adaptor Part Novu10f10e16as Model 907 , Swivel Tee, 7/8 Part Novu10f10e20ds Model 907 , Swivel Nut Elbow Part Novu10f10e21bs Model 907 , St. Adaptor Part Novu10f8e16as Model 907 , St. Adaptor Part Novu12f12e16as Model 907 , Swivel Elbow,90 Deg. Part Novu12f12e21bs Model 907 , Adaptor Part Novu12f12e33ds Model 907 , Adaptor Part Novu12f16e16as Model 907 , Swivel Nut Elbow Part Novu6f6e21bs Model 907 , Swivel Nut Elbow Part Novu6f6e21cs Model 907 , Swivel, Tee Part Novu6f6e25ds Model 907 , Swivel Nut Branch Tee Part Novu6f6e33ds Model 907 , Straight Adaptor Part Novu8f12e02as Model 907 , Fitting Part Novu8f12e02bs Model 907 , Hyd Fitting Part Novu8f12e16as Model 907 , Hyd Fitting Part Novu8f8e16as Model 907 , Elbow 90 Degree Part Novu8f8e21bs Model 907 , Adaptor Part Novu8f8e21cs Model 907 , Swivel Tee, 3/4 Part Novu8f8e26ds Model 907 , Hex Nut Part No369-0112 Model 907 , Bolt Hex M6x35 8.8 Zyp 5-8 M Part No370-0212 Model 907 , Hex Head Bolt Part No370-0240 Model 907 , Hex Head Bolt Part No370-0304 Model 907 , Hex Head Bolt Part No370-0306 Model 907 , Hex Head Bolt Part No370-0310 Model 907 , Hex Head Bolt Part No370-0404 Model 907 , Hex Head Bolt Part No370-0405 Model 907 , Hex Socket Head Cap Screw Part No370-2338 Model 907 , Hex Socket Head Cap Screw Part No370-2411 Model 907 , Flat Washer Part Nomaw08ga Model 907 , Flat Washer Part Nomaw10ga Model 907 , Flat Washer Part Nomaw12ga Model 907 , Spring Washer Part Nomdw06sa Model 907 , Spring Washer Part Nomdw08sa Model 907 , Spring Washer Part Nomdw10sa Model 907 , Spring Washer Part Nomdw12sa Model 907 , Hex Head Plug (Bsp) Part Nosc036/002 Model 907 , Hex. Head Plug (1-1/16Unf-2A) Part Nosc036/054 Model 907 , Sp. Elbow Part Noeea0027448 Model 907 , Pipe Manifold Part No907a020000056 Model 907 , Coupling Part Nostdd017/012 Model 907 , Coupling Part Nostdd017/013 Model 907 , Coupling Part Nostdd017/014 Model 907 , Hex Head Plug (Bsp) Part Nosc036/001 Model 907 , Hex Head Plug (Bsp) Part Nosc036/006 Model 907 , Hex Head Plug (Bsp) Part Nosc036/008 Model 907 , O Ring Part Nos3306 Model 907 , O Ring Part Nos3310n Model 907 , O Ring Part Nos3312n Model 907 , O Ring Part Nos3316n Model 907 , O Ring Part Nos3320 Model 907 , Flow Control Valve Part Nor2c050000101 Model 907 , O Ring Part Nos2803 Model 907 , Hex Head Bolt Part Nostdb035-12-30 Model 907 , Flanged Adaptor Part No910a020000227 Model 907 , Straight Adaptor Part Nose024/201 Model 907 , O Ring Part Nos2722 Model 907 , Hex Head Bolt Part Nostdb035-10-30 Model 907 , Manifold Block Part No910b050000054 Model 907 , Straight Adaptor Part Nose024/221 Model 907 , Special Fitting Part Noeea0029644 Model 907 , Hose Assy. Part Nostdd026/084 Model 907 , Bonded Seal Part Nosc011/013 Model 907 , Straight Adaptor Part Nose024/222 Model 907 , Straight Adaptor Part Nose024/430 Model 907 , Straight Adaptor M/M Part Nose024/207 Model 907 , Straight Adaptor Part Nose024/209 Model 907 , Straight Adaptor Part Nose024/212 Model 907 , Banjo Adaptor Assy. M/M Part Nose012/144 Model 907 , St. Adaptor Part Nose024/079 Model 907 , Swivel Nut Elbow Part Novu16f16e21bs Model 907 , Hose Assy. Part Nostdd033/031 Model 907 , Hose Assy. Part Nostdd033/110 Model 907 , Hose Assy. Part Nostdd026/152 Model 907 , Hose Assy. Part Nostdd026/104 Model 907 , Hex Head Bolt Part Nostdb035-10-25 Model 907 , Threaded Boss(M10x15lg) Part Noeea0016870 Model 907 , Hose Assy. Part Nostdd026/110 Model 907 , Transmission Hydraulic Group Part No907b070000032 Model 907 , Bracket For Trans. Filter Part No917a020000075 Model 907 , Flange Elbow Part No917a050000046 Model 907 , Adapter Male/Female - Jic Part Nod06a050000050 Model 907 , Gauge Adaptor Part Noeea0009296 Model 907 , Sp. Fitting Part Noeea0026859 Model 907 , Hose Assy. Part Nostdd026/306 Model 907 , Hose Assy. Part Nostdd033/055 Model 907 , Hose Assy. Part Nostdd033/060 Model 907 , Hose Assy. Part Nostdd033/062 Model 907 , St. Adaptor Part Novu12f12e16as Model 907 , Swivel Elbow,90 Deg. Part Novu12f12e21bs Model 907 , Elbow 45 Deg. Part Novu12f12e21cs Model 907 , Straight Adaptor Part Novu6f2e02as Model 907 , Swivel Nut Elbow Part Novu6f6e21bs Model 907 , Hex Head Bolt Part No370-0402 Model 907 , Spring Washer Part Nomdw12sa Model 907 , Bonded Seal Part Nosc011/024 Model 907 , Straight Adaptor Part Nose024/208 Model 907 , Hex Head Bolt Part Not6gg16 Model 907 , Hex Head Bolt Part Not8gg26 Model 907 , Hex Socket Head Cap Screw Part Not8gh28 Model 907 , Spring Washer Part Now6gf Model 907 , Spring Washer Part Now8gf Model 907 , Hyd. Oil Cooler Part No917b050000120 Model 907 , Hydraulic Cooler Matrix(40Kw) Part Noeea0027901 Model 907 , Transmission Cooler Matrix(70Kw) Part Noeea0027902 Model 907 , Brake Cooler Matrix(15Kw) Part Noeea0027903 Model 907 , Fan House-Em Part Noeea0027904 Model 907 , Fan-580/7/S38zl/38/Pag/74.75 Part Noeea0027905 Model 907 , Motor Bracket-Em Part Noeea0027906 Model 907 , Hydraulic Motor Part Noeea0027907 Model 907 , Seal Kit For Hyd. Motor Part Noeea0028875 Model 907 , Ring, Snap Part Noeea0028876 Model 907 , Lip Seal Part Noeea0028877 Model 907 , Spacer Part No907a020000070 Model 907 , Hex Head Bolt Part No370-0328 Model 907 , Flat Washer Part Now6ga Model 907 , Spring Washer Part Nomdw10sa Model 907 , Hex Head Bolt Part No370-0306 Model 907 , Spring Washer Part Nomdw12sa Model 907 , Hyd. Oil Cooler Mtg. Bracket Part No907b020000069 Model 907 , Hex Head Bolt Part No370-0240 Model 907 , Spring Washer Part Nomdw08sa Model 907 , Hex Head Bolt Part No370-0244 Model 907 , Hex Head Bolt Part No370-0405 Model 907 , Flat Washer Part Now5ga Model 907 , Front Control Panel Group Part No907b070000054 Model 907 , Front Control Panel Box Assy Part No907b040000006 Model 907 , Hex Head Bolt Part No370-0237 Model 907 , Hex Head Bolt Part No370-0306 Model 907 , Hex Head Bolt Part No370-0412 Model 907 , Mounting Plate Part No917a020000078 Model 907 , Front Panel Box Part No917b020000057 Model 907 , Clamp Part Noeea0007778 Model 907 , Front Control Panel Part No907b050000087 Model 907 , Rubber Sheet Part Noeea0025389 Model 907 , Flat Washer Part Nomaw10ga Model 907 , Flat Washer Part Nomaw12ga Model 907 , Spring Washer Part Nomdw08sa Model 907 , Spring Washer Part Nomdw10sa Model 907 , Spring Washer Part Nomdw12sa Model 907 , 7 Display Part No910b040000044 Model 907 , Connector Kit(Pv780) Part No910a040000045 Model 907 , Starting Switch Part No19wl040000073 Model 907 , Emergency Stop Push Button Part Noeea0022291 Model 907 , Emergency Stop Marker Part Noeea0029991 Model 907 , Relay Module Part Noepra040000007 Model 907 , Buzzer 24V Dc Part No19wl040000084 Model 907 , On Delay Timer (Crouzet) Part No910a040000059 Model 907 , Terminals Part Noeea0022453 Model 907 , Terminal Block(Black) Part Noeea0029389 Model 907 , Terminal End Plate Part Noeea0022455 Model 907 , End Clamps Part Noeea0021276 Model 907 , Terminal Block Part Noeea0028566 Model 907 , Terminal Block(Kut10,Yellow) Part Noeea0029453 Model 907 , Terminal Block(Kut10,Green) Part Noeea0029454 Model 907 , End Plate Part Noeea0028567 Model 907 , Mounting Rail Part Noeea0021275 Model 907 , Rect.Fork Type Terminal Part No912a040000095 Model 907 , Cable End Sleeve Terminal(2.5 Sq.Mm) Part Noeea0030029 Model 907 , Cable End Sleeve Terminal(1.5 Sq.Mm) Part Noeea0030028 Model 907 , Cable End Sleeve Terminal(6 Sq.Mm) Part Noeea0030117 Model 907 , Plate Part Noeea0029723 Model 907 , Slotted Pan Head Screw Part Nomt05eb16g Model 907 , Hex. Nut Part Nomt05lgg Model 907 , Rubber Sheet Part Noeea0026924 Model 907 , Rubber Sheet Part Noeea0026925 Model 907 , Plate Part Noeea0028469 Model 907 , Threaded Boss Part No811a060000056 Model 907 , Hex Head Bolt Part No370-0205 Model 907 , Spring Washer Part Nomdw06sa Model 907 , Slotted Button Head Screw Part No370-5113 Model 907 , Flat Washer Part Nomaw06ga Model 907 , S.C Cable Gland(3/4Et) Part Noeea0029761 Model 907 , S.C Cable Gland(3/4Et) Part Noeea0030009 Model 907 , S.C Cable Gland(1Et) Part Noeea0029760 Model 907 , Cable Gland Pvc Hood (3/4 Et) Part Noeea0029992 Model 907 , Cable Gland Pvc Hood (1 Et) Part Noeea0029993 Model 907 , Contact Block(No) Part Noeea0027986 Model 907 , Side Control Panel Box Assy Part No907b040000008 Model 907 , Hex Head Bolt Part No370-0238 Model 907 , Hex Head Bolt Part No370-0314B Model 907 , Side Control Panel Box Part No917b020000056 Model 907 , Mounting Rail Part Noeea0021275 Model 907 , Flat Washer Part Nomaw08ga Model 907 , Flat Washer Part Nomaw10ga Model 907 , Spring Washer Part Nomdw08sa Model 907 , Spring Washer Part Nomdw10sa Model 907 , Rubber Sheet Part Noeea0025422 Model 907 , Hex Head Bolt Part No370-0308 Model 907 , Slotted Pan Head Screw Part Nomt05eb16g Model 907 , Hex Head Bolt Part No370-0205 Model 907 , Spring Washer Part Nomdw06sa Model 907 , Flat Washer Part Nomaw06ga Model 907 , Hex Nut Part No369-0106 Model 907 , Hex Nut Part No369-0110 Model 907 , Side Control Panel Part No907b050000099 Model 907 , Push Button - 3 Position Part No116602 Model 907 , Selector Switch Part Noepra040000001 Model 907 , Selector Switch (3 Pos.) Part No910a040000014 Model 907 , Mecan1905 Part No907b040000001 Model 907 , Relay - 24 Volt Part No116600 Model 907 , Relay Module Part Noepra040000007 Model 907 , Timer Part Noeea0020754 Model 907 , Dc/Dc Convertor Part No907a040000030 Model 907 , Circuit Breaker, 32A Part Noeea0024825 Model 907 , Circuit Breaker, 6A Part No19wl871050265 Model 907 , Circuit Breaker,10A Part No19wl871050023 Model 907 , Circuit Breaker, 16A Part Noeea0025390 Model 907 , Mcb Link(10 Way) Part No907a040000004 Model 907 , Multi-Level Terminal Part Noeea0029579 Model 907 , End Plate Part Noeea0029611 Model 907 , Terminal Block(Black) Part Noeea0029389 Model 907 , Terminal End Plate Part Noeea0022455 Model 907 , End Clamps Part Noeea0021276 Model 907 , Terminal Block Part Noeea0028566 Model 907 , Terminal Block(Kut10,Yellow) Part Noeea0029453 Model 907 , Terminal Block(Kut10,Green) Part Noeea0029454 Model 907 , End Plate Part Noeea0028567 Model 907 , Mounting Din Rail Part Noeea0022456 Model 907 , Marker(15) Part No910a040000026 Model 907 , S.C Cable Gland(3/4Et) Part Noeea0029761 Model 907 , S.C Cable Gland(3/4Et) Part Noeea0030009 Model 907 , S.C Cable Gland(1Et) Part Noeea0029760 Model 907 , Cable Gland Pvc Hood (3/4 Et) Part Noeea0029992 Model 907 , Cable Gland Pvc Hood (1 Et) Part Noeea0029993 Model 907 , Positive Lock Female Terminal Part Noeea0025631 Model 907 , Diode Terminal Block Part Noeea0028499 Model 907 , Diode Block End Plate Part Noeea0029314 Model 907 , Rect.Fork Type Terminal Part No912a040000095 Model 907 , Diode Circuit Part No12wl040000213 Model 907 , Threaded Boss Part No811a060000056 Model 907 , Hex Head Bolt Part No370-0205 Model 907 , Flat Washer Part Nomaw06ga Model 907 , Spring Washer Part Nomdw06sa Model 907 , Slotted Pan Head Screw Part Nomt05eb16g Model 907 , Hex Nut Part No369-0106 Model 907 , Cable Duct Part Noeea0030113 Model 907 , Sleeve,Flexib(Bend)Spireal Cut Part No912a040000144 Model 907 , Cable End Sleeve Terminal(2.5 Sq.Mm) Part Noeea0030029 Model 907 , Cable End Sleeve Terminal(1.5 Sq.Mm) Part Noeea0030028 Model 907 , Cable End Sleeve Terminal(6 Sq.Mm) Part Noeea0030117 Model 907 , Male Connector Housing(12 Way) Part Noeea0028690 Model 907 , Male Wedge Lock(12 Way) Part Noeea0028698 Model 907 , Female Connector Housing(12 Way) Part Noeea0028694 Model 907 , Female Wedge Lock(12 Way) Part Noeea0028702 Model 907 , Male Connector Housing(6 Way) Part Noeea0028688 Model 907 , Male Wedge Lock(6 Way) Part Noeea0028696 Model 907 , Female Connector Housing(6 Way) Part Noeea0028692 Model 907 , Female Wedge Lock(6 Way) Part Noeea0028700 Model 907 , Socket For Dt Plug Part Noeea0027064 Model 907 , Pin For Dt Receptacle Part Noeea0027062 Model 907 , Terminating Resistor Link Part Noeea0026749 Model 907 , Cross Connection Link Assy Part Nostda038/05 Model 907 , Marker(0-100) Part No910a040000024 Model 907 , Marker(30) Part No910a040000025 Model 907 , Flexible Wire, 1.5 Sq.Mm, Pink Part Noeea0025274 Model 907 , Flexible Wire, 1.5 Sq.Mm, Blue Part Noeea0025275 Model 907 , Flexible Wire, 1.5 Sq.Mm, Yellow Part Noeea0025276 Model 907 , Flexible Wire, 1.5 Sq.Mm, Green Part Noeea0025277 Model 907 , Flexible Wire, 1.5 Sq.Mm, Violet Part Noeea0025278 Model 907 , Flexible Wire, 1.5 Sq.Mm, Red Part Noeea0025279 Model 907 , Flexible Wire, 1.5 Sq.Mm, Grey Part Noeea0025280 Model 907 , Flexible Wire, 1.5 Sq.Mm, White Part Noeea0025281 Model 907 , Flexible Wire, 1.5 Sq.Mm, Black Part Noeea0025282 Model 907 , Flexible Wire, 2.5 Sq.Mm, Red Part Noeea0025283 Model 907 , Flexible Wire, 6 Sq.Mm, Red Part Noeea0025285 Model 907 , Adjustable Cable Clamp Part No912a040000170 Model 907 , Heat Sleeve (5Mm) Part Noeea0027285 Model 907 , Ring Tongue Terminal Part No625a040000148 Model 907 , By-127 Diode For P.B.Station Part Noeea0002174 Model 907 , Rubber Sheet Part Noeea0026927 Model 907 , Rubber Sheet Part Noeea0026928 Model 907 , Straight Wire Butt Connector Part Noepra040000014 Model 907 , Gland Plate Part Noeea0030650 Model 907 , Duel Head Lamp Relay(24V) Part Noeea0030031 Model 907 , 6 Pole Female Connector Part No12wl040000181 Model 907 , Terminal Part Noeea0026062 Model 907 , Hex. Nut Part Nomt05lgg Model 907 , Female Connector Housing(2 Way) Part Noeea0028691 Model 907 , Female Wedge Lock(2 Way) Part Noeea0028699 Model 907 , Male Connector Housing(2 Way) Part Noeea0028687 Model 907 , Male Wedge Lock(2 Way) Part Noeea0028695 Model 907 , Multicore Control Cable(4X1.5) Part No907a040000025 Model 907 , Hose Sleeve Part No907a050000072 Model 907 , On Delay Timer (Crouzet) Part No910a040000059 Model 907 , Twin Cable End Sleeve Terminal(1.5 Sq.Mm) Part Noeea0030690 Model 907 , Led Work Light,45W,Low Beam Part No917a040000021 Model 907 , Led Work Light,45W,Wide Flood Part No917a040000022 Model 907 , Led Beacon Part No917a040000024 Model 907 , Led Flashing Light(Amber) Part No917a040000023 Model 907 , Led Tail Light Part No907a040000018 Model 907 , Led Work Light(15W) Part Nossla040000019 Model 907 , Paired Horn Part No919a002910934 Model 907 , Hyd. Oil Temp Sensor Part No917a040000006 Model 907 , Bracket Temp Prob. Mnt. Part No912a060000126 Model 907 , Side Mnt. Level Switch (N Part No912c040000105 Model 907 , Gasket Part No627b000000121 Model 907 , Hyd. Oil Filter Clogging Indicator Part No917a040000007 Model 907 , Capacitance Oil Level Switch(Falling) Part No917a040000026 Model 907 , Fuel Sensor(907) Part No907b040000013 Model 907 , Brake Oil Temp. Switch Part No917a040000005 Model 907 , Pressure Transmitter, 250 Bar Part No910a040000001 Model 907 , Wireless Camera Recording System Part No917b040000025 Model 907 , Wireless Camera Part No910a040000034 Model 907 , Wireless Camera Display Part No910a040000056 Model 907 , Reversing Alarm Part Noeea0022223 Model 907 , Emergency Stop Control Station Part Noeea0028455 Model 907 , Emergency Stop Marker Part Noeea0029991 Model 907 , Interior Light Part No910a040000029 Model 907 , 2 Pole Amp Connector Part Noeea0025257 Model 907 , 3 Pole Delphi Packard Connector Part Noeea0025258 Model 907 , Female Terminal-Metri Pack 150 Part Noeea0026863 Model 907 , Apc 312 Harness With Connector Part No910a040000002 Model 907 , Rd120 Harness Cum Connector Part Noeea0025260 Model 907 , Multicore Control Cable(2X1.5) Part No907a040000024 Model 907 , Multicore Control Cable(4X1.5) Part No907a040000025 Model 907 , Multicore Control Cable(7X2.5) Part No907a040000022 Model 907 , Multicore Control Cable(18X2.5) Part No907a040000023 Model 907 , Multicore Control Cable For Rc Part No912a040000157 Model 907 , Can Bus Cable Part No907a040000012 Model 907 , 6 Pole Female Sealed Connector(Dtm Series) Part Noeea0028818 Model 907 , Female Connector Housing(2 Way) Part Noeea0028691 Model 907 , Female Wedge Lock(2 Way) Part Noeea0028699 Model 907 , Male Connector Housing(2 Way) Part Noeea0028687 Model 907 , Male Wedge Lock(2 Way) Part Noeea0028695 Model 907 , Female Connector Housing(6 Way) Part Noeea0028692 Model 907 , Female Wedge Lock(6 Way) Part Noeea0028700 Model 907 , Male Connector Housing(6 Way) Part Noeea0028688 Model 907 , Male Wedge Lock(6 Way) Part Noeea0028696 Model 907 , Pin For Dt Receptacle Part Noeea0027062 Model 907 , Socket For Dt Plug Part Noeea0027064 Model 907 , Junction Box Part No907b040000026 Model 907 , Local Control Station Part No907b040000029 Model 907 , Cable Gland Pvc Hood (3/4 Et) Part Noeea0029992 Model 907 , Cable Gland Pvc Hood (1 Et) Part Noeea0029993 Model 907 , Cable End Sleeve Terminal(2.5 Sq.Mm) Part Noeea0030029 Model 907 , Cable End Sleeve Terminal(1.5 Sq.Mm) Part Noeea0030028 Model 907 , Positive Lock Female Terminal Part Noeea0025631 Model 907 , Cross Connection Link Assy Part Nostda038/05 Model 907 , Cross Connection Link Assy Part Nostda038/03 Model 907 , Cross Connection Link Assy Part Nostda038/02 Model 907 , Mounting Din Rail Part Noeea0022456 Model 907 , Multi-Level Terminal Part Noeea0029579 Model 907 , End Clamps Part Noeea0021276 Model 907 , Terminal End Plate Part Noeea0022455 Model 907 , Terminal Block(Black) Part Noeea0029389 Model 907 , Partition Plate Without Foot Part Noeea0030102 Model 907 , Battery,12V Part No12wl040000162 Model 907 , Battery Cut-Off Switch(Lockable) Part No910a040000033 Model 907 , Battery Switch Bracket Part No910a020000116 Model 907 , Battery Cable Assy. Pos. To Sw. Part No907b040000038 Model 907 , Battery Cable Assy Part No910a040000017 Model 907 , Battery Cable Assy. Sw. To Starter Part No907b040000039 Model 907 , Battery Cable Assy. Neg To Ground Part No907b040000040 Model 907 , Battery Cable Assy Part No910a040000020 Model 907 , Rubber Pad Part Noeea0027280 Model 907 , Rubber Pad Part Noeea0027279 Model 907 , Rubber Pad Part Noeea0027278 Model 907 , Airfilter Extension Cable Part Noeea0027658 Model 907 , Solenoid Connector(Led) Part Noeea0029713 Model 907 , Pg Cable Gland Pg13.5 Part Noeea0028456 Model 907 , Limit Switch Part No910a040000022 Model 907 , Plate Part Noeea0029957 Model 907 , Cable Gland(1/2 Npt) Part Noeea0029456 Model 907 , Roof Light Mtg. Bracket Part No907a020000019 Model 907 , Beacon Mtg. Bkt. Part No910a020000114 Model 907 , Light Mounting Bracket Part Noeea0029720 Model 907 , Guard Part Noeea0014429 Model 907 , Sleeve(10 Mm Dia) Part No19wl040000061 Model 907 , Sleeve(20 Mm Dia.) Part No19wl040000062 Model 907 , Cable Tie 3.6Mm X150mm Black Part No12wl040000035 Model 907 , Cable Tie 4.8Mm X 200 Mm Black Part No12wl040000040 Model 907 , Cab Lock Cable Ties Part No811a050000033 Model 907 , Clamp Part Noeea0028574 Model 907 , Clamp Part Noeea0007779 Model 907 , Clamp Part Noeea0007778 Model 907 , Hose Support Clamp Part Nostda037/32 Model 907 , Hose Support Clamp Part Nostda037/40 Model 907 , Hose Support Clamp Part Nostda037/76 Model 907 , Threaded Boss Part No811a020000105 Model 907 , Threaded Boss Part No811a060000056 Model 907 , Socket Head Cap Screw M5x35 L Part No370-2146 Model 907 , Slotted Button Head Screw Part No370-5113 Model 907 , Hex Socket Head Cap Screw Part No370-2171 Model 907 , Hex Socket Head Cap Screw Part Nomt05nh16 Model 907 , Slotted Button Head Screw Part No370-5122 Model 907 , Hex. Head Screw Part Nomt05lg16g Model 907 , Hex Head Bolt Part No370-0304 Model 907 , Hex Head Bolt Part No370-0238 Model 907 , Hex Head Bolt Part No370-0404 Model 907 , Hex Head Bolt Part No370-0306 Model 907 , Hex Head Bolt Part No370-0237 Model 907 , Hex Head Bolt Part No370-0240 Model 907 , Hex Head Bolt Part No370-0204 Model 907 , Hex Head Bolt Part No370-0242 Model 907 , Hex Head Bolt Part No370-0142 Model 907 , Hex Socket Head Cap Screw Part No370-2170 Model 907 , Hex Head Bolt Part No370-0140 Model 907 , Spring Washer Part Nomdw05sa Model 907 , Spring Washer Part Nomdw06sa Model 907 , Spring Washer Part Nomdw08sa Model 907 , Spring Washer Part Nomdw10sa Model 907 , Spring Washer Part Nomdw12sa Model 907 , Spring Washer Part Nomdw04sa Model 907 , Flat Washer Part Nomaw05gag Model 907 , Flat Washer Part Nomaw06ga Model 907 , Flat Washer Part Nomaw08ga Model 907 , Flat Washer Part Nomaw10ga Model 907 , Medium Washer Part Nomaw04gcg Model 907 , Hex Nut Part No369-0106 Model 907 , Hex Nut Part No369-0108 Model 907 , Cable Tags(910) Part No910b040000036 Model 907 , Hose Sleeve Part No907a050000072 Model 907 , Hose Sleeve Part No907a050000073 Model 907 , Electronic Joystick(2 Axis) Part No917b040000013 Model 907 , Deutsche 6 Pole Male Connector Part Noeea0025246 Model 907 , Deutsche 6 Pole Female Connector Part Noeea0025247 Model 907 , Controller Part No910a040000046 Model 907 , Connector Kit(Iqan-Mc42) Part No910a040000047 Model 907 , Bracket Part No917a020000051 Model 907 , Bracket Part No917a020000052 Model 907 , Plate Part Noeea0027696 Model 907 , Hex Head Bolt Part No370-0205 Model 907 , Slotted Button Head Screw Part No370-5114 Model 907 , Hex Nut Part No369-0103 Model 907 , Hex Head Bolt Part No370-0308 Model 907 , Hex Nut Part No369-0110 Model 907 , Hex Socket Head Cap Screw Part No370-2141 Model 907 , Battery Guard Part No907a020000052 Model 907 , Flashing Led,Red Part No912a040000216 Model 907 , Rubber Pad Part Noeea0029908 Model 907 , Yellow Sticker Kit Part No910b040000037 Model 907 , Bracket Part Noeea0031308 Model 907 , Flange Pipe Weldment Part No907b020000103 Model 907 , Expansion Bellow Part No907b050000096 Model 907 , Flange Pipe Weldment Part No907b020000100 Model 907 , Silencer Weldment Assy. Part No907b020000009 Model 907 , Flane Top Part Noeea0027144 Model 907 , Catalytic Converter With Muffler Part No917b050000121 Model 907 , Flane Bottom Part Noeea0027145 Model 907 , Flange Pipe Weldment Part No907b020000082 Model 907 , Bracket, Exhaust Part No907b020000008 Model 907 , Gasket For Exhaust Part No907a050000011 Model 907 , Gasket Part No907a050000085 Model 907 , Threaded Boss Part Noeea0027140 Model 907 , Hex Head Bolt Part No370-0611 Model 907 , Flat Washer Part Nomaw16ga Model 907 , Spring Washer Part Nomdw16sa Model 907 , Flat Washer Part Now6ga Model 907 , Flat Washer Part Now5ga Model 907 , Hex Head Bolt Part No370-0244 Model 907 , Hex Head Bolt Part No370-0250 Model 907 , Hex Nut Part No369-0108 Model 907 , Hex Head Bolt Part No370-0308 Model 907 , Spring Washer Part Nomdw10sa Model 907 , Hex Nut Part No369-0110 Model 907 , Spring Washer Part Nomdw08sa Model 907 , Hex Head Bolt Part No370-0312 Model 907 , Fume Diluter Group Part No907b070000072 Model 907 , Mounting Plate, Fume Diluter Part No907b020000104 Model 907 , Flange Pipe Weldment Part No907b020000105 Model 907 , Clamp Part No912b020000419 Model 907 , Exhaust Gas Diluter Part No912b050000318 Model 907 , Gasket Part Noeea0028557 Model 907 , Hex Nut Part No369-0112 Model 907 , Flat Washer Part Nomaw12ga Model 907 , Spring Washer Part Nomdw12sa Model 907 , Spring Washer Part Nomdw16sa Model 907 , Hex Head Bolt Part Nostdb035-12-40 Model 907 , Hex Head Bolt Part Nostdb035-16-30 Model 907 , Hex Head Bolt Part Not7gg20 Model 907 , Spring Washer. Part Now7gf Model 907 , Fibre Glass Tape Part No910a050000031 Model 907 , Fiber Glass Wool Part No907a050000045 Model 907 , Galvanise Wire Part Noeea0027482 Model 907 , Heat Insulation Jacket Part No907a050000100 Model 907 , Cooler Guard Part No907b020000106 Model 907 , Grill Part No907b070000075 Model 907 , Flat Washer Part Nomaw08ga Model 907 , Spring Washer Part Nomdw08sa Model 907 , Hex Nut Part No369-0108 Model 907 , Hex Head Bolt Part No370-0248 Model 907 , Hex Head Bolt Part No370-0250 Model 907 , Support Bracket Part No907b020000037 Model 907 , Support Bracket Part No907a020000038 Model 907 , Support Bracket Part No907a020000039 Model 907 , Support Bracket Part No907a020000107 Model 907 , Support Bracket Part No907a020000108 Model 907 , Support Bracket Part No907a020000119 Model 907 , Support Bracket Part No917a020000021 Model 907 , Cover Part No907a020000004 Model 907 , Cover, Air Intake Part No907a020000057 Model 907 , Cover Part No907a020000109 Model 907 , Cover Part No907a020000110 Model 907 , Guard Plate Part No907a020000114 Model 907 , Guard Plate Part No907a020000115 Model 907 , Plate Part No907a020000116 Model 907 , Cover Part No907b020000036 Model 907 , Cover Part No907b020000111 Model 907 , Cover Part No907b020000112 Model 907 , Cover Part No907b020000113 Model 907 , Cover Part No917a020000038 Model 907 , Cover Part No917a020000039 Model 907 , Clamp Part Noeea0007778b Model 907 , Flat Washer Part Nomaw12ga Model 907 , Cover Part No917a020000041 Model 907 , Cover Part No917a020000042 Model 907 , Exhaust Cover Assy. Part No907b070000074 Model 907 , Exhaust Cover Part No907a020000117 Model 907 , Exhaust Cover Part No907a020000118 Model 907 , Cover Plate Part Noeea0033191 Model 907 , Cover Plate Part Noeeb0033187 Model 907 , Plate Part Noeea0033188 Model 907 , Plate Part Noeea0033189 Model 907 , Threaded Boss(M10x15lg) Part Noeea0016870 Model 907 , Hex Head Bolt Part No370-0206 Model 907 , Hex Head Bolt Part No370-0240 Model 907 , Hex Head Bolt Part No370-0304 Model 907 , Flat Washer Part Nomaw06ga Model 907 , Flat Washer Part Nomaw08ga Model 907 , Spring Washer Part Nomdw06sa Model 907 , Spring Washer Part Nomdw08sa Model 907 , Spring Washer Part Nomdw10sa Model 907 , Stopper Part No917a020000040 Model 907 , Hand Rest Seat Part No907a050000069 Model 907 , Hex Nut Part No369-0108 Model 907 , Avm Part No907a050000092 Model 907 , Threaded Boss Part Noeea0003462 Model 907 , Flat Washer Part Nomaw10ga Model 907 , Flat Washer Part Nomaw12ga Model 907 , Flat Washer Part Nomaw16ga Model 907 , Flat Washer Part Nomaw20ga Model 907 , Spring Washer Part Nomdw08sa Model 907 , Spring Washer Part Nomdw10sa Model 907 , Spring Washer Part Nomdw12sa Model 907 , Spring Washer Part Nomdw16sa Model 907 , Spring Washer Part Nomdw20sa Model 907 , Hex Nut Part No369-0110 Model 907 , Hex Nut Part No369-0112 Model 907 , Hex Nut Part No369-0116 Model 907 , Hex Head Bolt Part No370-0240 Model 907 , Hex Head Bolt Part No370-0306 Model 907 , Hex Head Bolt Part No370-0308 Model 907 , Hex Head Bolt Part No370-0310 Model 907 , Hex Head Bolt Part No370-0312 Model 907 , Hex Head Bolt Part No370-0316 Model 907 , Hex Head Bolt Part No370-0404 Model 907 , Hex Head Bolt Part No370-0406 Model 907 , Hex Head Bolt Part No370-0412 Model 907 , Hex Head Bolt Part No370-0606 Model 907 , Hex Head Bolt Part No370-0609 Model 907 , Hex Head Bolt Part No370-0613 Model 907 , Hex Head Bolt Part No370-0809 Model 907 , Cover, Fuel Tank Part No910a020000239 Model 907 , Gasket Part No910a050000068 Model 907 , Hex Head Bolt Part Nostdb035-12-30 Model 907 , Battery Box Part No907b020000125 Model 907 , Cover,Battery Part No910a020000213 Model 907 , Clamp, Battery Part Noeea0031720 Model 907 , Flat Washer Part Nomaw10ga Model 907 , Spring Washer Part Nomdw10sa Model 907 , Hex Head Bolt Part Nostdb035-10-20 Model 907 , Hex Head Bolt Part Nostdb035-10-30 Model 907 , Hex Nut Part No369-0110 Model 907 , Threaded Boss Part Noeea0007149 Model 907 , Hex Head Bolt Part No370-0304 Model 907 , Hex Head Bolt Part No370-0403 Model 907 , Cover Part No811b020000150 Model 907 , Gasket Part No811b050000067 Model 907 , Conveyor Assy. Part No907a070000080 Model 907 , Threaded Boss Part Noeea0007149 Model 907 , Spring Washer Part Nomdw10sa Model 907 , Hex Head Bolt Part No370-0310 Model 907 , Bracket Part No907a070000081 Model 907 , Bracket Part No907b020000124 Model 907 , Name Plate (Fuel) Part No912a050000001 Model 907 , Name Plate (Hyd. Oil) Part No912a050000003 Model 907 , Name Plate (M/C Sr. No) Part No100618 Model 907 , Warning Plate(Do Not Stand Here) Part No016b000091012 Model 907 , Name Plate, Model Part No907a050000009 Model 907 , Decal, Tire Pres. Part No246918 Model 907 , Name Plate, Pressure Reading Part No907a050000077 Model 907 , Name Plate,Caution Safety Link Part Noxa1365 Model 907 , Name Plate, Joy Stick Operation Part No907a050000078 Model 907 , Warning Plate - Caution Crush Hazard Part No822a050000034 Model 907 , Hydraulic Oil - Identification Plate Part No822a050000035 Model 907 , Lubrication Plate Part No907a050000010 Model 907 , Voltage Indicator Plate Part No822a050000037 Model 907 , Warning Plate Part No917a050000040 Model 907 , Warning Plate - Danger Area Part No822a050000039 Model 907 , Name Plate - Steering Operation Part No822a050000040 Model 907 , Name Plate - Operator Control Part No822a050000041 Model 907 , Brake Hyd. Oil Identification Plate Part No917a050000044 Model 907 , Warning Plate- Do Not Touch Part No917a050000045 Model 907 , Name Plate-Pressure Check Points Part No917a050000083 Model 907 , Name Plate, Emergency Steering Part No907a050000076 Model 907 , Name Plate, Air Filter Part No907a050000058 Model 907 , Name Plate, Park Brake Release Part No907a050000059 Model 907 , Name Plate, Engine Start Stop Part No907a050000060 Model 907 , Name Plate, Weld Instruction Part No907a050000061 Model 907 , Name Plate, Battery Switch Part No907a050000062 Model 907 , Air Intake Kit Part No907b050000013 Model 907 , Air Cleaner Assy Part Noeea0027315 Model 907 , Hose Part Noeea0027316 Model 907 , Hose Clamp, T Bolt Part Noeea0027317 Model 907 , Precleaner, Metal Part Noeea0027318 Model 907 , Bracket Mounting Assy Part Noeea0027319 Model 907 , Bracket Mounting, Powder Coated Part Noeea0027320 Model 907 , Rain Hood, Metal Part Noeea0027321 Model 907 , Hose Elbow Part Noeea0027322 Model 907 , Hose Clamp, T Bolt Part Noeea0027323 Model 907 , Pipe Assy, Powder Coated Part Noeea0027324 Model 907 , Hose Part Noeea0027325 Model 907 , Pipe Assy, Powder Coated Part Noeea0027326 Model 907 , Bracket Assy Part Noeea0027327 Model 907 , Restriction Indicator Part Noeea0027328 Model 907 , Hose Clamp T-Bolt Part Noeea0029203 Model 907 , Hose Reducer Part Noeea0029205 Model 907 , Bracket, Air Cleaner Part No907a020000025 Model 907 , Hex Head Bolt Part No370-0304 Model 907 , Hex Head Bolt Part No370-0308 Model 907 , Spring Washer Part Nomdw10sa Model 907 , Flat Washer Part Nomaw10ga Model 907 , Hex Nut Part No369-0110 Model 907 , Adapter Part No907a050000020 Model 907 , Bracket, Air Filter Part Noeea0027682 Model 907 , Th. Boss Part Noeea0027216 Model 907 , Hex Head Bolt Part No370-0310 Model 907 , Filter Element, Primary Part Noeea0027698 Model 907 , Filter Element, Safety Part Noeea0027699 Model 907 , Tool Kit Part No907a070000017 Model 907 , Axle Oil Part No12wl050000144 Model 907 , Lithium Base Grease Part Noxa1417 Model 907 , Fire Extinguisher Part No625a050000110 Model 907 , Drive Screw Part Not1000 Model 907 , Engine Oil Part No907a050000006 Model 907 , Fastner Sealant Part No00ea000001155 Model 907 , Hydraulic Oil Part Nod10a050000093 Model 907 , Brake Oil Part No917a050000049 Model 907 , Centralised Lubrication System (Automatic) Part No917b050000022 Model 907 , Engine Coolant Part No907a050000007 Model 907 , Front Reflector Part No12wl040000125 Model 907 , Rear Reflector Part No12wl040000126 Model 907 , Reflective Tape (Red) Part No19wl050000631 Model 907 , Reflective Tape (White) Part No19wl050000630 Model 907 , Reflective Tape (Yellow) Part No19wl050000632 Model 907 , O Ring Kit Part No917a050000113 Model 907 , Automatic Fire Suprression System Part No907a070000027 Model 907 , Automatic Fire Detection & Supression System Part No19wl050000868 Model 907 , Bracket (Fire System) Part No19wl020000733 Model 907 , Threaded Boss Part No811a020000105 Model 907 , Hex Head Screw Part Nomt08lg16g Model 907 , Spring Washer Part Nomdw08sag Model 907 , Hex Nut Part Nomt08lgg Model 907 , Flat Washer Part Nomaw08gag Model 907 , Accumulator Charging Kit Part No811a050000124 Model 907 , Hand Pump Part No907a050000048 Model 907 , Hand Pump Part No917a050000106 Model 907 , Single Core Wire Rubber Bidding Part Nod06a050000189 Model 907 , Logo-Eimco Elecon(Engine Hood) Part No12wl050000047 Model 907 , Wheel Choke Part No910a050000034 Model 907 , E.M Tyre Inflating & Checking Device Lb Part No907a050000064 Model 907 , Engine Cooler Group Part No907b070000070 Model 907 , Cac Cooler Assy. Part No907b070000071 Model 907 , Cac With Radiator Part No907b050000094 Model 907 , Cac Cooler Mtg. Bracket Part No907b020000092 Model 907 , Hex Head Bolt Part Nostdb035-16-35 Model 907 , Spring Washer Part Nomdw16sa Model 907 , Hex Head Bolt Part Nostdb035-10-35 Model 907 , Spring Washer Part Nomdw10sa Model 907 , Flat Washer Part Nomaw10gab Model 907 , Cac Tube, Inlet Part No907b020000093 Model 907 , Cac Silicone Hose Part No907a050000028 Model 907 , T-Bolt Hose Clamp Part No907a050000034 Model 907 , Cac Tube, Outlet Part No907b020000094 Model 907 , Elbow,Cac Part No910a050000074 Model 907 , Radiator Tube, Inlet Part No907b020000095 Model 907 , Silicone Hose, Coolant Part No907a050000029 Model 907 , Silicone Hose, Coolant Part Noeea0027283 Model 907 , T-Bolt Hose Clamp Part No907a050000032 Model 907 , Silicone Hose, Coolant Part No907a050000030 Model 907 , Silicone Hose, Coolant Part Noeea0027284 Model 907 , T-Bolt Hose Clamp Part No907a050000033 Model 907 , Radiator Tube, Outlet Part No907b020000096 Model 907 , Elbow Hose, Coolant Part No907a050000031 Model 907 , Coolant Hose Part Noeea0027289/006 Model 907 , Hose Clamp Part Nop9phb Model 907 , Coolant Hose Part Noeea0027287/004 Model 907 , Hose Clamp (Fuel Circuit) Part No12wl050000172 Model 907 , Nipple Part No907a020000024 Model 907 , Bonded Seal Part Nosc011/016 Model 907 , Coolant Hose Part Noeea0027287/001 Model 907 , Coolant Hose Part Noeea0027287/006 Model 907 , Hex Head Plug (Bsp) Part Nosc036/004 Model 907 , Bonded Seal Part Nosc011/024 Model 907 , Hex Head Plug (Bsp) Part Nosc036/008 Model 907 , T-Bolt ( Hose-Clamp) (Heavey Duty) Part No19wl050000052 Model 907 , Hex Head Plug (Bsp) Part Nosc036/002 Model 907 , Bonded Seal Part Nosc011/009 Model 907 , Sponge (Side) Part No12wl050000123 Model 907 , Rubber Sheet Part Noeea0032933 Model 907 , Ball Valve(G 1/2) Part Norb2c050000137 Model 907 , Hose Assembly Part No623d02584/113 Model 907 , St.Swivel Adaptor M/F Part Nose012/064 Model 907 , Straight Adaptor, M/M Part Nose012/084 Model 907 , Tank Mounting Bracket Part No910b020000254 Model 907 , Threaded Boss (M12) Part Noeea0002561 Model 907 , Threaded Boss Part Noeea0033008 Model 907 , Hex Nut Part No369-0110 Model 907 , Hex Head Bolt Part No370-0308 Model 907 , Th. Boss Part Noeea0027216 Model 907 , Flat Washer Part Nomaw10ga Model 907 , Elbow, Coolant Tube Part No910b020000178 Model 907 , Bush (Metric) Part Nombh100/116/50A Model 907 , Bush,Metric Part Nombh100/116/70A Model 907 , Bush (Metric) Part Nombh90/106/100A Model 907 , Pin Part No917a060000009 Model 907 , Bush (Metric) Part Nombh90/106/60A Model 907 , Pin Part No917a060000015 Model 907 , Pin Part No917a060000012 Model 907 , Spherical Bearing Part Nostdc003/056 Model 907 , Seal Part Noseg251 Model 907 , O Ring Part Noseg1099 Model 907 , Wear Washer Part No912b060000117 Model 907 , Counter Balance Valve Part Noeea0027160 Model 907 , Valve Seal Kit Part Noeea0028796 Model 907 , Counter Balance Valve Part Noeea0027167 Model 907 , Valve Seal Kit Part Noeea0028811 Model 907 , Spherical Bearing Part Noeea0022799 Model 907 , Avm, Engine Part No910a050000025 Model 907 , Avm, Engine Part No19wl050000865 Model 907 , Spider Assembly (7C) Part No912a050000208 Model 907 , Radial Seal Ring Part Noeea0027541 Model 907 , Radial Seal Ring Part Noeea0027555 Model 907 , Spider Assy. - 6C Part No907a050000050 Model 907 , Relief Valve Assy. Part No625b050000064 Model 907 , Pres.Gauge Isolator Valve Part No811a050000013 Model 907 , Drive Oil Pressure Gauge Part No813b000000182 Model 907 , Oil Pressure Gauge Part No917b050000080 Model 907 , Hydraulic Motor Part Noeea0027907 Model 907 , Fan Part Noeea0027905 Model 907 , Lip Seal Part Noeea0028877 Model 907 , Selector Switch (2 Pos.) Part No910a040000013 Model 907 , Joystick Handle(Walvoil) Part No12wl040000189 Model 907 , Temperature Sensor Part Noeea0027843 Model 907 , Sensor Part Noeea0027837 Model 907 , Sensor Part Noeea0027819 Model 907 , V-Ribbed Belt Part Noeea0027827 Model 907 , Accelerator Pedal Part Noeea0027831 Model 907 , Cab Control Part Noeea0025805 Model 907 , Transmission Temp. Sensor(917) Part Noeea0026850 Model 907 , Transmission Pressure Sensor(917 Part Noeea0026851 Model 907 , Hyd. Motor - Cr Part No611b050000321 Model 907 , Hose Assy. Part Nostdd026/301 Model 907 , Gauge Adaptor Part No811a060000088 Model 907 , Oil Filter Kit Part No907a050000055 Model 907 , Bonded Seal Part Nosc011/006 Model 907 , Fuel Filter Insert Part No907a050000052 Model 907 , Fuel Filter Part No907a050000053 Model 907 , Fuel Filter Insert Part No907a050000054 Model 907 , Minimess Coupling Part No822a050000031 Model 907 , Service Control Valve Part No917b050000015 Model 907 , Repair Kit (Accumulator Charge Valve) Part Noeea0025349 Model 907 , Twin Oil Cooler Part No917b050000021 Model 907 , Power Relay(24V) Part No19wl040000115 Model 907 , Base For Change Over Relay Part No12wl040000024 Model 907 , Fuel Tank Cap With Neck Part No907a050000068 Model 907 , Suspension Tube Type-A Part Noclsa020000034 Model 907 , Cac With Radiator Part No907b050000023 Model 907 , Radiator Cooler Matrix(115Kw) Part Noeea0027908 Model 907 , Seal Kit Part Noeea0029259 Model 907 , Transmission Control Unit(Econ.A312) Part Noeea0028730 Model 907 , Tcu Harness (Apc - 312) Part Noeea0033374 Model 907 , Cooler Fan, Sucker Part No907b050000095 Model 907 , Smart Relay Part Noeea0035781c Model 907 , Bearing Shell Part Noeea0037186c Model 907 , Cylinder Head Gasket Part Noeea0031824 Model 907 , Gasket Part Noeea0031839 Model 907 , Injector Part Noeea0031872 Model 907 , Valve Cover Gasket Part Noeea0027749 Model 907 , Flange Screw Part Noeea0037183c Model 907 , Flange Screw Part Noeea0037184c Model 907 , Waste Gate Solenoid Valve Part Noeea0029451 Model 907 , Coil Part Noeea0026837 Model 907 , Up To 1000 Hrs Filter Kit Part No907a070000088 Model 907 , Oil Filter Part Noeea0035443c Model 907 , Cylinder Head Part Noeea0035983c Model 907 , Cylinder Liner Kit Part Noeea0031825 Model 907 , Gasket Part Noeea0031828 Model 907 , Plane Gasket Part Noeea0031853 Model 907 , Ecu (Without Software) Part Noeea0032212 Model 907 , Piston Part No201c000000054 Model 21 , Comp. Ring Part No201a000000072 Model 21 , Oil Ring Part No201a000000073 Model 21 , Connecting Rod Part No201e000000053 Model 21 , Retaining Ring Part No201a000000048 Model 21 , Bushing Part No201a000000049 Model 21 , Hex Head Bolt Part Not8hg24 Model 21 , Crank Sleeve Part No201b000000759 Model 21 , Crank Shaft Part No201m000000087 Model 21 , Bearing Part Nog201 Model 21 , Vent Cap Assy Part No200m000000084 Model 21 , Valve And Housing Group Part No201m000000110 Model 21 , Valve Housing Cover Part No201b000000066 Model 21 , Valve Housing Gasket Part No201a000000065 Model 21 , Gasket For Motor Housing Part No021a000000196 Model 21 , Wrist Pin Assembly Part No201m000000086 Model 21 , Hex Head Bolt Part Not8gg16 Model 21 , Cylinder Part No201c000000744 Model 21 , Cylinder Gasket Part No201a000000064 Model 21 , Gasket Set Part No201m000000637 Model 21 , Valve Housing Part No201m000000090 Model 21 , Gasket,Cover Part No021d000000182 Model 21 , Seal Part Nos1301 Model 21 , Shim Set Part Noga62a Model 21 , Axle Bearing Cap Part No021c000000181 Model 21 , Motor Pinion Part No021b000000198 Model 21 , Motor Pinion Spacer Part No021a000000197 Model 21 , Bearing Part Nog132 Model 21 , Motor Pinion Assy Part No021m000000114 Model 21 , Clutch Group Part No021m000003075 Model 21 , Clutch Shaft Assy Part No021m000003076 Model 21 , Bearing Part Nog135 Model 21 , Clucth Thrust Washer Part No021a000003082 Model 21 , Clucth Coller Assy Part No021m000000148 Model 21 , Clutch Jaw Part No021b000003081 Model 21 , Key Part Nokwt Model 21 , Clutch Pinion Assy. Part No021m000003078 Model 21 , Clucth Gear Part No021c000003080 Model 21 , Clutch Rod Part No012a000000029 Model 21 , Spring Part Noza63 Model 21 , Seal Rod Part No021a000000030 Model 21 , Shim Set Part Nogb32a Model 21 , Lower Deck Intermediate G Part No021m000000115 Model 21 , Lower Deck Intermediate Part No021m000000116 Model 21 , L.D.Gear Part No021b000000016 Model 21 , Key Part Nokwv Model 21 , L.D.Int.Pinion Part No021b000000035 Model 21 , Lower Deck Idler Group Part No021m000000117 Model 21 , Lower Deck Idler Shaft As Part No021m000000118 Model 21 , Bearing Part Nog140 Model 21 , Shaft-L.D.Gear Part No021b000000036 Model 21 , L.D.Idler Gear Part No021b000000017 Model 21 , Axle Gear Part No021b000000178 Model 21 , Key Part Nokw36 Model 21 , Axle Guage - 610 Mm Part No021a000000211 Model 21 , King Bolt Type B Part No021m000000160 Model 21 , Centering Roller Group Part No021m000001708 Model 21 , Hex Nut, Slotted Part Not16gv Model 21 , Roller Assy Part No024m000000819 Model 21 , Anchor Roller Centering Part No021b000001707 Model 21 , Ball Race,Ud Part No021c000000150 Model 21 , Balls Part Nogr16 Model 21 , Ball Race,Ld Part No021c000000151 Model 21 , Ud Gr Housing Covr Gasket Part No021c000000042 Model 21 , Upper Deck Idler Shaft Assy. Part No021m000000123 Model 21 , Upper Deck Idler Shaft Part No021a000000037 Model 21 , U.D.Idler Gear Part No021b000000018 Model 21 , Upper Deck Intermediate G Part No021m000000124 Model 21 , Upper Deck Inter. Shaft A Part No021m000000125 Model 21 , Gear Part No021b000000019 Model 21 , Woodruff Key Part Nokw29 Model 21 , U.D.Int.Shaft & Pinion Part No021a000000038 Model 21 , Bearing Part Nog138 Model 21 , Chain Reel Group Part No021m000000126 Model 21 , Chain Reel Shaft Assy Part No021m000000127 Model 21 , Chain Reel Gear Part No021b000000020 Model 21 , Chain Reel Shaft Part No021b000000039 Model 21 , Key Part Nokw34 Model 21 , Bearing Part Nog144 Model 21 , Bearing Part Nog145 Model 21 , Seal Part Nos265 Model 21 , Chain Reel Part No021c000000014 Model 21 , Chain Link Pin Part No012a000000041 Model 21 , Spring Washer Part Now6gf Model 21 , Chain Roller Assy Part No021m000000132 Model 21 , Hex Nut Part Not24gg Model 21 , Chain Roller Shaft Part No021b000000052 Model 21 , Roller, Bucket Chain Part No021a000000053 Model 21 , Lock Washer Part Nol49 Model 21 , Lock Nut Part Nol819 Model 21 , Bearing Part Nog121 Model 21 , Grease Nipple Part Nobp1fg Model 21 , Linkage Pin Cen.Drum Levr Part No021a000000046 Model 21 , Bush,Centring Drum Linkage Part No021a000000045 Model 21 , Hex Nut Part Not20gg Model 21 , Centering Drum Lever Part No021c000000043 Model 21 , Seal Part Nos219 Model 21 , Bearing Cup Part Nog510 Model 21 , Bearing Cone Part Nog511 Model 21 , Shim Set Part Nogb80a Model 21 , Hex Head Bolt Part Not10gg24 Model 21 , Centering Drum Cover Gasket Part No021a000000051 Model 21 , Hex Nut Part Not18gg Model 21 , Spring Washer Part Now18gf Model 21 , Thrust Stop Part No021b000000068 Model 21 , Bumper Spring Clamp Part No021a000000070 Model 21 , Bumper Spring Part No021a050000003 Model 21 , Spring Washer Part Now8gf Model 21 , Hex Nut Part Not8gg Model 21 , Hex Head Bolt Part Not6gg32 Model 21 , Spring Part No012a000000085 Model 21 , Bucket Handle Part No012d000000084 Model 21 , Traction Valve Lever Part No012b000000093 Model 21 , Balance Spring Part No012a000000094 Model 21 , Spring Washer Part Now5gf Model 21 , Hex Nut Part Not5hg Model 21 , Hex Head Bolt Part Not6gg24 Model 21 , Handle Assy Part No012m000000141 Model 21 , Traction Control Handle Part No012b000000096 Model 21 , Traction Handle Retainer Part No012b000000099 Model 21 , Traction Pivot Bushing Part No012a000000097 Model 21 , Shim Set Part Noga31a Model 21 , Pivot Handle Part No012a000000098 Model 21 , Traction Bonnet Group Part No012m000000140 Model 21 , Traction Valve Bonnet Part No012c000000090 Model 21 , Gasket Part Nosga30 Model 21 , Valve Stem Part No012a000000088 Model 21 , Traction Valve Disc Part No012b000000086 Model 21 , Valve Disc Spring Part No012a000000081 Model 21 , Bucket Bonnet Group Part No021m000000139 Model 21 , Valve Stem Part No012a000000082 Model 21 , Bucket Valve Disc Part No012c000000079 Model 21 , Swivel Sleeve Assy Part No012m000000138 Model 21 , Air Screen Part No012a000000076 Model 21 , Swivel Gasket Part No012a000000077 Model 21 , Drain Cock Part Nobp3rvd Model 21 , Gasket Part Nosga36 Model 21 , Bonnet Part No021d000000080 Model 21 , Grease Nipple Part Nobp1fg Model 21 , Hex Nut Part Not8gg Model 21 , Traction Air Hose Assy Part No021m000000270 Model 21 , Hex Nut, Nyloc Part Nol211 Model 21 , Flat Washer Part Now12ga Model 21 , Cable Spring Part No021a000000297 Model 21 , Rocker Arm Cable Long Part No021b000000290 Model 21 , Rocker Arm Cable Short Part No021b000000295 Model 21 , End Link Pin Part No021a000000040 Model 21 , Split Pin Part Nol119 Model 21 , End Link Part No021a000000057 Model 21 , Bucket Chain Assy Part No021m000000134 Model 21 , Chain Repair Kit Part No021m000000939 Model 21 , Bucket Bottom,Casting Part No021a030000011 Model 21 , Bucket Assy.(Type48) Part No021m000002620 Model 21 , Air Motor Assy. Part No201m000000091 Model 21 , Piston Group Assy Part No201m000000085 Model 21 , Crank Shaft Group Part No201m000000088 Model 21 , Plain Crankshaft Assembly Part No201m000000760 Model 21 , Rotary Valve Assembly Part No201m000000089 Model 21 , Axle Cap (18-30 Ga.) Part No021m000000253 Model 21 , L.D. Motor Pinion Part No150b060000001 Model 150 , Spacer Part No012a000000197 Model 150 , Bearing Part Nog130 Model 150 , L.D. Pinion Part No150b060000002 Model 150 , Bearing Part Nog132 Model 150 , Gear Part No021c000003080 Model 150 , Woodruff Key Part Nokw29 Model 150 , Gear Part No021b000000016 Model 150 , Bearing Part Nog135 Model 150 , Gear Part No150b060000005 Model 150 , Axle Cap Part No021c000000181 Model 150 , Shim Set Part Noga62a Model 150 , Seal Part Nos1301 Model 150 , Hub Part No150c060000009 Model 150 , Wheel Tyre Assy. Part No150m100000004 Model 150 , Key Part Nok12r66 Model 150 , Drain Cock Part Nobp2rve Model 150 , Hex Head Bolt Part Not10gg24 Model 150 , Washer Part Now10gf Model 150 , Key Part Nokwt Model 150 , Bolt Part Not8gsk8 Model 150 , Bolt Part Not10gg28 Model 150 , Axle Nut Part No021a000000185 Model 150 , Washer Part No021a000000184 Model 150 , Wheel Stud Part No802a000000708 Model 150 , Wheel Nut Part No802a000000709 Model 150 , Wheel Nut Part Nol262t Model 150 , Gasket Part No012a000000196 Model 150 , Washer Part Now6gf Model 150 , Cap Screw Part Not6gg28 Model 150 , Cap Screw Part Not6gg24 Model 150 , Gasket Part No200a000000065 Model 150 , Valve Housing Cover Part No200a000000066 Model 150 , Cap Screw Part Not6gg64 Model 150 , Cap Screw Part Not6gg14 Model 150 , Gasket Part No200a000000064 Model 150 , Cylinder Part No200c000000050 Model 150 , Washer Part No200a000000099 Model 150 , Cap Screw Part Not7gg16 Model 150 , Wrist Pin Part No200m000000086 Model 150 , Oil Ring Part No200a000000073 Model 150 , Comp. Ring Part No200a000000072 Model 150 , Piston Part No200c000000054 Model 150 , Connecting Rod Part No200d000000053 Model 150 , Connecting Rod Bushing Part No200a000000049 Model 150 , Retainer Ring Part No200a000000048 Model 150 , Bearing Part Nog200 Model 150 , Valve Housing Assy Part No200m000000090 Model 150 , Rotary Valve Assy Part No200m000000089 Model 150 , Air Motor Part No270m000000006 Model 150 , Bearing Part Nog107 Model 150 , Bush Part No150a060000011 Model 150 , U D Idler Gear Part No012b000000018 Model 150 , Pinion Part No012a000000038 Model 150 , U D Intetmediate Gear Part No012b000000019 Model 150 , Chain Reel Shaft Part No012b000000039 Model 150 , Bearing Part Nog138 Model 150 , Chain Reel Gear Part No012b000000020 Model 150 , Bearing Part Nog142 Model 150 , Chain Reel Part No150c030000001 Model 150 , Seal Part Nos197 Model 150 , Chain Link Pin Part No012a000000041 Model 150 , Gasket Part No012b000000042 Model 150 , Shim Set Part Noga16ax Model 150 , Chain Roller Shaft Part No630b000000081 Model 150 , Roller Part No630c000000083 Model 150 , Chain Assy. Part No021m000000133 Model 150 , End Link Pin Part No021a000000040 Model 150 , Cotter Pin Part Nol119 Model 150 , End Link Part No021a000000057 Model 150 , Spring Part No012a000000069 Model 150 , Bolt Part Not6gg16 Model 150 , Bolt Part Not8gg24 Model 150 , Washer Part Now8gf Model 150 , Bolt Part Not10gg20 Model 150 , Bolt Part Not12gg48 Model 150 , Bolt Part Not12gg20 Model 150 , Washer Part Now12gf Model 150 , Washer Part Now20gf Model 150 , Cap Screw Part Not8gg20 Model 150 , Gasket Part Nosga32a Model 150 , Seal Part Nos2300 Model 150 , Cap Screw Part Not6ggw16 Model 150 , Cap Screw Part Not6gg20 Model 150 , Bearing Part Nog280 Model 150 , Crank Shaft Part No200m000000517 Model 150 , Rotary Valve Part No270d000000002 Model 150 , Valve Housing Part No270d000000003 Model 150 , Bearing Part Nog2003 Model 150 , Bearing Part Nog2004 Model 150 , Bucket Part No150e020000094 Model 150 , Bucket Lip Part Noeea0004865 Model 150 , Seal Part Nos300 Model 150 , Bush Part Noibh48/56/48A Model 150 , Cap Screw Part Not8gh24 Model 150 , Nut Part Not10gg Model 150 , Flat Washer Part Now24gab Model 150 , Connecting Link Part No150b020000022 Model 150 , Bolt Part Not4gg8 Model 150 , Locking Plate Part Nosc009/003 Model 150 , Locking Plate Part Nosc009/002 Model 150 , Pin Part No150a060000016 Model 150 , Spring Bush Part Noibh24/32/16A Model 150 , Nut Part Not8gg Model 150 , Pin Part No150a060000015 Model 150 , Bolt Part Not4gg16 Model 150 , Lock Washer Part Now4gf Model 150 , Bolt Part Not12gg28 Model 150 , Nut Part Not12gg Model 150 , Pneumatic Cyl. Part No150b050000043 Model 150 , Pin Part No150a060000014 Model 150 , Seal Kit ( Suitable For # 150M10000005) Part Noeea0000690 Model 150 , Nipple Part Nobp8fna Model 150 , Union Elbow Part Nobp8bsl Model 150 , Adaptor Part Nose012/085 Model 150 , Manifold Part No150b020000028 Model 150 , Elbow Part Nose012/026 Model 150 , Adaptor Part Nose012/086 Model 150 , Adaptor Part Nose012/007 Model 150 , Elbow Part Nobp6bl Model 150 , Pipe Part Nobp6fn28 Model 150 , Elbow Part Nobp6bl Model 150 , Pipe Part Nobp6fn40 Model 150 , Hose Assy Part No623d02584/230 Model 150 , Adaptor Part Nose012/006 Model 150 , Adaptor Part Nose012/097 Model 150 , Elbow Part Nose012/027 Model 150 , Hose Assy Part No623d02584/238 Model 150 , Hose Assy Part No623d02584/242 Model 150 , Allen Bolt Part No370-2235 Model 150 , Washer Part Nomdw08sa Model 150 , Nut Part No369-0108 Model 150 , Bolt Part No370-0264 Model 150 , Adaptor Part Nose012/046 Model 150 , Adaptor Part Nose012/066 Model 150 , Union Part Nobp6bs Model 150 , Hose Clip Part Nop9phb Model 150 , Pn.Control Valve(1/2Bsp) Part Noeeb0010031 Model 150 , Gear Part No150c060000019 Model 150 , Side Ring Part No802b060000003 Model 150 , Locking Ring Part No802b060000002 Model 150 , Seal Part Nos115 Model 150 , Motor Pinion Part No150b060000018 Model 150 , Retaining Ring Part Nol1118 Model 150 , Circlip Part Nol1166 Model 150 , Gasket Part Nosga24a Model 150 , Gasket Part No150b050000024 Model 150 , Gasket Part No150b050000025 Model 150 , Motor Pinion Part No150b060000031 Model 150 , Spacer Part No150a060000032 Model 150 , Shaft Part No150a060000035 Model 150 , Pinion Part No150b060000033 Model 150 , Bearing Part No150a050000029 Model 150 , Gear Part No150b060000034 Model 150 , Key Part Nomk64r40 Model 150 , Key Part Nomk75r56 Model 150 , Shim Set Part No150a050000026 Model 150 , Pinion Part No150b060000037 Model 150 , Gear Part No150b060000038 Model 150 , Shaft Part No150a060000040 Model 150 , Bearing Housing Part No150b060000036 Model 150 , Gear Part No150b060000041 Model 150 , Axle Part No150c060000043 Model 150 , Gear Part No150b060000044 Model 150 , Spacer Part No150a060000042 Model 150 , Bearing Part No150a050000030 Model 150 , Seal Part Noseg242 Model 150 , Shim Set Part No150a050000027 Model 150 , Hub Part No150c060000054 Model 150 , Wheel Rim Assy Part No150d050000021 Model 150 , Tube Part No802a050000002 Model 150 , Flap Part No802a050000003 Model 150 , Bkt.Chain Roller Part No021a000000053 Model 150 , Pin Part No150b060000060 Model 150 , Spacer Part No150a060000062 Model 150 , Bearing Part Nog121 Model 150 , Gasket Part No150b050000023 Model 150 , Motor Pinion Part No150b060000047 Model 150 , Spacer Part No150a060000061 Model 150 , Seal Part Noseg170 Model 150 , Shaft Part No150a060000049 Model 150 , Gear Part No150b060000048 Model 150 , Pinion Part No150b060000051 Model 150 , Key Part Nomk60r45 Model 150 , Gear Part No150b060000050 Model 150 , Chain Reel Shaft Part No150b060000053 Model 150 , Seal Part Noseg203 Model 150 , Gear Part No150b060000052 Model 150 , Key Part Nomk66r63 Model 150 , Bumper Spring Part No150a050000022 Model 150 , Cylinder Part No150b020000108 Model 150 , Pin Part No150a060000056 Model 150 , Lock Plate Part No150a020000112 Model 150 , Keeper Plate Part Nolka24a Model 150 , Bearing Part No150a050000028 Model 150 , Circlip Part No912a050000006 Model 150 , Pin Part No150b060000058 Model 150 , Spacer Part No150a060000057 Model 150 , Chain Assy Part No150b070000021 Model 150 , Bumper Spring Clamp Part No021a000000070 Model 150 , Pin Part Nomkd25a66 Model 150 , Bush Part Noibh32/40/32A Model 150 , Spacer Part No150a020000047 Model 150 , Spring Part No824a000000277 Model 150 , Spacer Part Nogsa8d Model 150 , Gasket Part No824b000000215 Model 150 , Bush Part Nosd001/014 Model 150 , Link Part No623a000003189 Model 150 , Link Part No623a000003190 Model 150 , Pin Part No623a000003191 Model 150 , Pin Part No623a000003856 Model 150 , Hose Assy Part Nostdd018/108 Model 150 , Hose Assy Part Nostdd018/223 Model 150 , Hose Assy Part Nostdd018/226 Model 150 , Hose Assy Part Nostdd018/246 Model 150 , Hose Assy Part Nostdd018/250 Model 150 , Wheel Stud Part No150a060000064 Model 150 , Wheel Nut Part No150a060000065 Model 150 , Lock Nut Part No803b000000488 Model 150 , Collar Assy Part No00eb000000037 Model 150 , Arm (L H) Part No150d020000099 Model 150 , Arm (R H) Part No150d020000100 Model 150 , Lock Nut Part Nol274 Model 150 , Pn.Control Valve(1/2Bsp) Part Noeeb0010031 Model 150 , Motor Pinion Part No150b060000039 Model 150 , Cover, Lower Deck Gear Bo Part No150b020000113 Model 150 New , Cover,L.D.Gear Box Part No150b020000114 Model 150 New , Bearing Housing Part No150b060000046 Model 150 New , Bearing Housing Part No150b060000045 Model 150 New , Air Motor Arrangement Part No270m100000004 Model 150 New , Valve Housing Group Part No270m000000194 Model 150 New , Complete Crankshaft Group Part No200m000000530 Model 150 New , Piston Group Part No200m000000085 Model 150 New , Motor Housing Assembly Part No270m000000007 Model 150 New , Crank Sleeve Part No200b000000047 Model 150 New , Upper Deck Part No150d020000102 Model 150 New , Upper Deck Gear Box Part No150d020000101 Model 150 New , Gear Box Part No150d020000098 Model 150 New , Hopper Assy Part No150b070000074 Model 150 New , Hopper Support Bracket Part No150d020000110 Model 150 New , Upper Deck Gbox Assy. Part No150m100000055 Model 150 New , Guard, Upper Deck Part No150b020000049 Model 150 New , Hopper-Lh Part No150b020000136 Model 150 New , Hopper-Rh Part No150b020000137 Model 150 New , Hopper Door Part No150b020000134 Model 150 New , Side Plate,Rh Part No150b020000052 Model 150 New , Side Plate,Lh Part No150b020000053 Model 150 New , Shaft Part No803b000000004 Model 824 , Gear (Model 824) Part No803b000000182 Model 824 , Key Part Nok58r40 Model 824 , Motor Pinion Spacer Part No021a000000197 Model 824 , Tab Washer Part No803a000000441 Model 824 , Gear Part No803b000000183 Model 824 , Bearing Part Nog140 Model 824 , Shaft Part No803b000000007 Model 824 , Gear Part No803b000000008 Model 824 , Bearing Part Nog142 Model 824 , Key Part Nok60r40 Model 824 , Gear Part No803b000000010 Model 824 , Bearing Part Nog144 Model 824 , Shaft Part No803b000000011 Model 824 , Gasket Part No803a000000223 Model 824 , Bearing Part Nog138 Model 824 , Key Part Nok12r66 Model 824 , Hex Socket Set Screw Part Not10gs12 Model 824 , Shaft Assy Part No803m000000304 Model 824 , Bearing Part Nog146 Model 824 , Bearing Part No803a000000019 Model 824 , Bearing Cup Part Nog484 Model 824 , Bearing [Cone] Part No803a000000022 Model 824 , Key Part Nok64r58 Model 824 , Gear Part No803b000000012 Model 824 , Bearing Part Nog427 Model 824 , Bearing Cup Part Nog444 Model 824 , Oil Seal Part No803a000000020 Model 824 , Gasket Part No803d000000003 Model 824 , Shim Set Part No803b000000016 Model 824 , Plug Part No1027a050000003 Model 824 , Axle Cap Part No00eb000000094 Model 824 , Gear Box Cover Part No00ec000000131 Model 824 , Key Part Nok60r36 Model 824 , Spacer Part No803a000000124 Model 824 , Sealing Plate Part No803b000000015 Model 824 , Square Head Plug Part Nop9bp Model 824 , Dowel Pin Part No012a000001102 Model 824 , Spacer Part No803a000000121 Model 824 , Spacer Part No803a000000122 Model 824 , Spacer Part No803a000000123 Model 824 , Washer Part No621a000000074 Model 824 , Hex Nut, Nyloc Part Nol274 Model 824 , Lock Nut Part No803b000000488 Model 824 , Wheel Stud Part No802a000000708 Model 824 , Hex Nut, Nyloc Part Nol262t Model 824 , Wheel Nut Part No802a000000709 Model 824 , Upper Deck Assy. Part No824m000000324 Model 824 , Slotted Bolt (A Size) Part No824b000000415 Model 824 , Wedge Part No824b000000416 Model 824 , Spring Washer Part Now10gf Model 824 , Hex Nut Part Not10gg Model 824 , Hex Nut, Slotted Part Not24gk Model 824 , Cotter Pin Part Nol153 Model 824 , Stud Part No00ea000000122 Model 824 , Side Sheet-Lh Part No824c000000327 Model 824 , Side Sheet-Rh Part No824c000000328 Model 824 , Bumper Bar Assy. Part No824m000000113 Model 824 , Hex Nut Part Not14gg Model 824 , Spring Washer Part Now14gf Model 824 , Lock Plate For Model 824 Part No00ea000000168 Model 824 , Taper Wedge Part No00ea000000158 Model 824 , Spring Washer Part Now16gf Model 824 , Gear Box Assy. -Bucket Drive Part No824m000000334 Model 824 , Upper Chain Roller Assy Part No824m000000193 Model 824 , First Intermediate Pinion Part No630b000000247 Model 824 , Gear Chain Reel Bucket Drive Part No630c000000248 Model 824 , Bearing Cartridge Part No630b000000272 Model 824 , Brg.Cartridge Chain Reel Shaft Part No630c000000274 Model 824 , 1St Int.Brg.Cartridge Part No630b000000275 Model 824 , Gasket,Motor Pinion Cap Part No630a000000290 Model 824 , Gasket,Bucket Drive Cover Part No630c000000292 Model 824 , Chain Reel Part No004c000000169 Model 824 , Chain End Pin Lock Part No004a000000182 Model 824 , Intermediate Gear Part No824c000000041 Model 824 , Chain Roller Assy Part No021m000000132 Model 824 , Bearing Part Nog204 Model 824 , Bucket Drive Hsg.Cover Plate Part No824e000000420 Model 824 , Motor Pinion Bucket Drive Part No824b000000040 Model 824 , Bearing Part Nog448 Model 824 , Bearing Cone Part Nog449 Model 824 , Bearing Part Nog546 Model 824 , Bearing Part Nog547 Model 824 , Bearing Part Nog548 Model 824 , Bearing Part Nog549 Model 824 , Bearing Part Nog562 Model 824 , Bearing Part Nog563 Model 824 , Brass Shim Set Part Nog1214 Model 824 , Shim Set Part Nog1215 Model 824 , Shim Set Part Nog1227 Model 824 , Seal Part Nos300 Model 824 , Key Part Nok10e60 Model 824 , Key Part Nok12e58 Model 824 , Key Part Nok8r34 Model 824 , Hex Head Bolt Part Not8ggw20 Model 824 , Hex Head Bolt Part Not8ggw16 Model 824 , Inter.Gear For Buc.Drive Part No630c000000245 Model 824 , 2Nd Int.Pinion Bucket Drive Part No630c000000249 Model 824 , Bearing Cone Part Nog533 Model 824 , Bearing Cup Part Nog534 Model 824 , Bearing Cone Part Nog531 Model 824 , Bearing Cup Part Nog532 Model 824 , Key Part Nok12e28 Model 824 , Chain Real Shaft Part No630c000000258 Model 824 , Square Head Plug Part Nobp2bp Model 824 , Pipe Plug Part Nobp6bp Model 824 , Plug, Csk Square Part Nobp5bpa Model 824 , Chain Roller Shaft Part No630b000000081 Model 824 , Shim Set Part Noga16ax Model 824 , Bearing Cone Part Nog403 Model 824 , Bearing Cup Part Nog416 Model 824 , Chain Roller Part No630c000000083 Model 824 , Gasket Part Nosga32a Model 824 , Seal Part Nos2300 Model 824 , Grease Fitting Part Nop2fg Model 824 , Retainer Plate Part No630a000000138 Model 824 , Chain Roller Cap Part No630b000000084 Model 824 , Chain Roller Shaft Part No021b000000052 Model 824 , Bearing Part Nog121 Model 824 , Roller, Bucket Chain Part No021a000000053 Model 824 , Lock Washer Part Nol49 Model 824 , Lock Nut Part Nol819 Model 824 , Spring Washer Part Now24gf Model 824 , Hex Nut Part Not24gg Model 824 , Bucket Chain Part No824m000000157 Model 824 , Bucket Chain Assy Part No630m000002361 Model 824 , End Link Pin Part No621a000000666b Model 824 , Cylinder Assy Part No803m000000099 Model 824 , Collar Assy Part No00eb000000037 Model 824 , Rocker Arm Cable Part No630b000002487 Model 824 , Cable Spring Part No630a000000042 Model 824 , Bumper Spring Part No024b000000220 Model 824 , Pin Part No803b000000138 Model 824 , Cable Pin Part Nohra196 Model 824 , Hex Nut, Nyloc Part Nol213 Model 824 , Cotter Pin Part Nol163 Model 824 , Rocker Arm R.H. Part No824m000000380 Model 824 , Rocker Arm L.H. Part No824m000000378 Model 824 , Rocker Arm Yoke Bar Part No824d000000101 Model 824 , Air Motor Assy Part No201m000005046 Model 824 , Gasket For Motor Housing Part No021a000000196 Model 824 , Wrist Pin Assembly Part No201m000000086 Model 824 , Cylinder Part No201c000000744 Model 824 , Cylinder Gasket Part No201a000000064 Model 824 , Bearing Part Nog267 Model 824 , O Ring Part No621a000000545 Model 824 , Valve Housing Cover Part No271c000000020 Model 824 , Ext Circlip 5100-255 Part Nol1126 Model 824 , Bearing Part Nog134 Model 824 , Oil Ring Part No201a000000073 Model 824 , Piston Part No201c000000054 Model 824 , Comp. Ring Part No201a000000072 Model 824 , Vent Cap Assy Part No200m000000084 Model 824 , Drain Cock, Valve Part Nobp2rve Model 824 , Plug,Sq.Head Part Nop2fp Model 824 , Crank Shaft Group Plain Part No201m000000465 Model 824 , Bearing Part Nog278 Model 824 , Bushing Part No201a000000049 Model 824 , Crank Sleeve Part No201b000000759 Model 824 , Retaining Ring Part No201a000000048 Model 824 , Connecting Rod Part No201e000000053 Model 824 , Bearing Adaptor Part No201a000000733 Model 824 , Crank Shaft Assy Part No201m000000761 Model 824 , Hex Head Bolt Part Not8hg24 Model 824 , Cap Screw Washer Part No201a000000099 Model 824 , Rotary Valve Part No271d000000002 Model 824 , Valve Housing Part No271e000000004 Model 824 , Motor Housing Part No201e000000763 Model 824 , Pitcher Tee Part No623a000002559 Model 824 , Elbow M/F Taper Seat Part Nobp7bsla Model 824 , Sediment Trap Assy. Part No623m000002511 Model 824 , Union Elbow,90 Degree F/F Part Nobp7bsl Model 824 , Union Part Nobp7bsa Model 824 , Union, Female Part Nobp7bs Model 824 , Elbow,Std.90 Degree F/F Part Nobp7bl Model 824 , Elbow Std 45 Deg. Part Nop9bla Model 824 , Elbow Street, 45 Degree M/F Part Nobp7blc Model 824 , Close Nipple Part Nobp9fna Model 824 , Nipple Part Nobp7fna Model 824 , Elbow,45 Degree F/F Part Nobp7bla Model 824 , Stand Pipe Part No623a000002655 Model 824 , Hose Clip Part Nop105phb Model 824 , Stand Pipe (1 1/4 Bspt) Part No621a000000202 Model 824 , Hose Clamp Part Nop9phb Model 824 , Hose Clip Part Nop13phb Model 824 , Hose Clamp Part Nop10phb Model 824 , Nipple Part Nobp7fn40 Model 824 , Nipple Part Nobp7fn32 Model 824 , Nipple Part Nobp7fn20 Model 824 , Nipple Part Nobp7fn28 Model 824 , Nipple Part Nobp7fn44 Model 824 , Nipple Part Nobp7fn48 Model 824 , Nipple Part Nobp9fn30 Model 824 , Nipple Part Nobp7fn34 Model 824 , Air Control Valve Assy Part No824m000000272 Model 824 , Air Control Valve Assy. Part No824m000000274 Model 824 , Control Handle Assy Part No623c000003187 Model 824 , Control Handle Assy.L.H. Part No623c000003195 Model 824 , Link Part No623a000003189 Model 824 , Link Part No623a000003190 Model 824 , Pin Part No623a000003191 Model 824 , Pin Part No623a000003856 Model 824 , Valve Manifold (Traction) Part No824c000000267 Model 824 , Tab Washer Part Nosd014/019 Model 824 , E Clip - 9 Mm Part Nosc020/012 Model 824 , Valve Manifold Part No824c000000294 Model 824 , Control Handle Part No824c000000295 Model 824 , Air Control Vlv Assy-Service Part No824b070000011 Model 824 , Latch Part No824b000000268 Model 824 , Valve Handle Grip Part No621a000000110 Model 824 , Cap Part No024b000000794 Model 824 , Spacer Part Nogsa8d Model 824 , Spring Part No824a000000277 Model 824 , Hex Socket Head Cap Screw Part Not8gmn32 Model 824 , Gasket For Cont.Valvebody Part No824b000000215 Model 824 , Bush Part Nosd001/014 Model 824 , Flat Washer Part Now8ga Model 824 , Spring Washer Part Now6gf Model 824 , Valve End Plate. Part No824m000000269 Model 824 , Swivel Assy Part No623m000004263 Model 824 , Oiler Head Assy Part No623m000002749 Model 824 , Screen Oiler Cap Part No630a000000273 Model 824 , Oiler Filler Plug Part No630a000000271 Model 824 , Drain Cock Part Nobp3rvd Model 824 , Air Screen Part No012a000000076 Model 824 , Lock Washer Part Nolla5 Model 824 , Gasket Part Nosga24a Model 824 , Flat Washer Part Nowa1 Model 824 , Flat Washer Part Nowa2 Model 824 , Bucket Bottom,Cast Part No824d000000229 Model 824 , Bucket Assy.(0.425 Cu.M.) Part No824m000000231 Model 824 , Hull Group Part No824m100000013 Model 824 New , Basic Gear Box Part No824m100000014 Model 824 New , Square Head Plug Part Nop4bp Model 824 New , Gear Box Part No824m000000314 Model 824 New , Spacer(Large) Part No824b000000401 Model 824 New , Spacer (Small) Part No824b000000402 Model 824 New , Tab Washers Part Nosd014/065 Model 824 New , Tab Washers Part Nosd014/013 Model 824 New , Tab Washer Part Nosd014/063 Model 824 New , Wheel Assy. Part No824a070000012 Model 824 New , Tyre 7.00X12x14 Ply Part No824a050000006 Model 824 New , Upper Deck Group Part No824b070000013 Model 824 New , Motor Mtg. Cover Part No201c000005043 Model 824 New , Motor Housing Assy Part No201m000000762 Model 824 New , Hex Head Plug (Bsp) Part Nosc036/009 Model 824 New , Crank Shaft Group Part No201m000005052 Model 824 New , Bucket Drive Housing Part No824e000000333 Model 824 New , Upper Deck Part No824c020000033 Model 824 New , Rail Thrust End-Rh Part No824d000000344 Model 824 New , Rail Thrust End-Lh Part No824d000000345 Model 824 New , Rocker Arm Group Part No824m000000382 Model 824 New , Pneumatic Control Group Part No824b070000016 Model 824 New , Oiler Bottle Assy. Part No630m000005161 Model 824 New , Air Control Valve Assy.-Traction Part No824b070000014 Model 824 New , Air Control Valve , Service Part No824b070000015 Model 824 New , Ball Valve Part No150a050000039 Model 824 New , Needle Valve Part No150a050000033 Model 824 New , Tee,Special Part No824a020000024 Model 824 New , Tee, Reducing Branch Part Nobp8bts7 Model 824 New , Coupling Part Nostdd017/012 Model 824 New , Bearing Cup/Cone Part Nog484/803A000000022 Model 824 New , Bearing Cup/Cone Part Nog427/444 Model 824 New , Bearing Cup/Cone Part Nog448/449 Model 824 New , Bearing Cup/Cone Part Nog546/547 Model 824 New , Bearing Cup/Cone Part Nog548/549 Model 824 New , Bearing Cup/Cone Part Nog562/563 Model 824 New , Bearing Cup/Cone Part Nog533/534 Model 824 New , Bearing Cup/Cone Part Nog531/532 Model 824 New , Bearing Cup/Cone Part Nog403/416 Model 824 New , Bearing Cup/Cone Part Nog510/G511 Model 824 New , Front End Assy.(Pp 2.0 Cu.M.) Part No912b070000383 Model 912Lhd , Arm Assy.(Pp Bkt.) Part No912m100000299 Model 912Lhd , Arm (P.P. Bucket) Part No912d020000409 Model 912Lhd , Bush,Metric Part Nombh100/116/70A Model 912Lhd , Lever Assy. Part No912m100000249 Model 912Lhd , Dump Lever Part No912c030000021 Model 912Lhd , Bush (Metric) Part Nombh125/145/100A Model 912Lhd , Link Assy. Part No912a070000297 Model 912Lhd , Link Part No912a030000031 Model 912Lhd , Bush (Metric) Part Nombh75/85/75A Model 912Lhd , Roll Back Cylinder Part No912b050000282 Model 912Lhd , Spherical Bearing Part Nostdc003/047 Model 912Lhd , Circlip Part Noeea0016332 Model 912Lhd , Grease Nipple Part Noeea0015106 Model 912Lhd , Seal Kit (* Marked Items) Part Noeea0016352 Model 912Lhd , Valve -Seal Kit ( * ) Part Noeea0020818 Model 912Lhd , Circlip Part Noeea0021612 Model 912Lhd , Grease Nipple With Cap Part Noeea0020796 Model 912Lhd , Seal Kit For (*) Marked Item Part Noeea0021634 Model 912Lhd , Lift Cylinder Part No912b050000283 Model 912Lhd , Head End Cover Part Noeea0016338 Model 912Lhd , Load Cartridge Valve Part Noeea0015117 Model 912Lhd , Counter Balance Valve Part Noeea0020817 Model 912Lhd , Seal Kit For (*) Marked Item Part Noeea0021635 Model 912Lhd , P.P. Bucket Assy.(2.0 Cu.M.) Part No912m100000265 Model 912Lhd , Bucket,Push Plate Part No912m100000266 Model 912Lhd , Lip, Bucket Part No912c030000017 Model 912Lhd , Spacer Part Noeea0020665 Model 912Lhd , Locking Ring Part Noeea0002017 Model 912Lhd , Push Plate,Upper Part No912d020000355 Model 912Lhd , Spacer Part Noeea0009768 Model 912Lhd , Spacer Part Noeea0020664 Model 912Lhd , Push Plate,Lower Part No912c020000356 Model 912Lhd , Shaft Upper Part No912a060000130 Model 912Lhd , Shaft Lower Part No912a060000129 Model 912Lhd , Flat Washer Part Nomaw24ga Model 912Lhd , Push Plate Cylinder Part No912b050000285 Model 912Lhd , Circlip Part Noeea0015103 Model 912Lhd , Circlip Part Noeea0020952 Model 912Lhd , Spherical Bearing Part Nostdc003/036 Model 912Lhd , Seal Kit For (*) Marked Item Part Noeea0021637 Model 912Lhd , Pin Part No912b060000138 Model 912Lhd , Pin (F.F. To R/B) Part No811b060000117 Model 912Lhd , Hex Head Bolt Part Nostdb035-10-120 Model 912Lhd , Spring Washer Part Nomdw10sa Model 912Lhd , Hex Head Bolt Part Nostdb035-10-75 Model 912Lhd , Pin (Arm - Bucket) Part No912b060000113 Model 912Lhd , Pin (Arm - Bucket) Part No912b060000114 Model 912Lhd , Pin (Link-Lev/Bucket) Part No912b060000136 Model 912Lhd , Pin (F.F.- Dump Cyl.) Part No912b060000101 Model 912Lhd , Pin (Lever-Dump Cyl.) Part No912b060000137 Model 912Lhd , Pin (F.F.- Arm) Part No912b060000106 Model 912Lhd , Pin (F.F.- Arm) Part No912b060000107 Model 912Lhd , Pin (F.F.- Lift Cyl.) Part No912b060000108 Model 912Lhd , Pin (Arm - Lift Cyl.) Part No912b060000111 Model 912Lhd , Pin (Arm/Lever) Part No912b060000135 Model 912Lhd , Hex Head Bolt Part Nostdb035-20-55 Model 912Lhd , Hex Head Bolt Part Nostdb035-20-45 Model 912Lhd , Hex Socket Head Cap Screw Part No370-2608 Model 912Lhd , Hex Head Bolt Part Nostdb035-12-150 Model 912Lhd , Hex Head Bolt Part Nostdb035-12-35 Model 912Lhd , Hex Head Bolt Part Nostdb035-10-35 Model 912Lhd , Spring Washer Part Nomdw20sa Model 912Lhd , Spring Washer Part Nomdw16sa Model 912Lhd , Hex Nut Part No369-0112 Model 912Lhd , Grease Nipple Part Nobp1fg Model 912Lhd , Hex Head Bolt Part Nostdb035-16-35 Model 912Lhd , Pin Assy. Part No912b020000479 Model 912Lhd , Pin Part No912b060000161 Model 912Lhd , Hex Head Bolt Part Nostdb035-10-70 Model 912Lhd , Pin Assy. Part No912b020000480 Model 912Lhd , Hex Head Bolt Part Nostdb035-12-25 Model 912Lhd , Rubber Guard-Wheel Part No912a050000232 Model 912Lhd , Clamp Part Noeea0007778 Model 912Lhd , Clamp Part Noeea0007779 Model 912Lhd , Clamp Part Noeea0007780 Model 912Lhd , Rear End Assy Part No912c070000398 Model 912Lhd , Boss Part No19wl020000427 Model 912Lhd , Suction Pipe Assy Part Noeea0033572 Model 912Lhd , Threaded Boss Part Noeea0028450 Model 912Lhd , Canopy Bkt Part No912a020000826 Model 912Lhd , Spherical Bearing Part Nostdc003/056 Model 912Lhd , Bush,Metric Part Nombh150/170/140A Model 912Lhd , Wear Washer Part No912b060000117 Model 912Lhd , Seal Part Noseg251 Model 912Lhd , O Ring Part Noseg1099 Model 912Lhd , Hex Socket Head Cap Screw Part No370-2232 Model 912Lhd , Steering Cylinder Part No912b050000284 Model 912Lhd , Circlip Part Noeea0016355 Model 912Lhd , Bearing Part Nostdc003/030 Model 912Lhd , Seal Kit (* Marked Items) Part Noeea0016353 Model 912Lhd , Seal Kit For (*) Marked Item Part Noeea0021636 Model 912Lhd , Canopy Assy Part No912b070000379 Model 912Lhd , Flat Washer Part Nomaw16gag Model 912Lhd , Hex Head Bolt Part Nostdb035-16-45 Model 912Lhd , Flat Washer Part Nomaw20gag Model 912Lhd , Washer Part Nomaw16gcg Model 912Lhd , Hex Head Bolt Part Nostdb035-16-60 Model 912Lhd , Spacer Part No912a060000195 Model 912Lhd , Bolster (M/C) Part No912b020000839 Model 912Lhd , Seat- Hyd Suspension Part No907a050000093 Model 912Lhd , Fuel Tank Cover Part No912a020000797 Model 912Lhd , Return Pipe Part Noeea0033571 Model 912Lhd , Pipe Part Noeea0031079 Model 912Lhd , Fuel Tank Cap With Neck Part No907a050000068 Model 912Lhd , Gasket,Diesel Tank Cover Part No910a050000078 Model 912Lhd , Cover Part No811b020000150 Model 912Lhd , Gasket Part No811b050000067 Model 912Lhd , Plug Part No1027a050000003 Model 912Lhd , Steel Ball Part Nogr6 Model 912Lhd , Oil Level Window Part No241a000000284 Model 912Lhd , Hex Hd Bolt (Bolster) Part No912a060000133 Model 912Lhd , Suction Strainer Part No625b050000070 Model 912Lhd , Pin (F.F.- St.Cyl.) Part No912b060000104 Model 912Lhd , Pin (R.F.- St.Cyl.) Part No912b060000105 Model 912Lhd , Spacer Part No912a060000123 Model 912Lhd , Clamp Half Part No912b060000115 Model 912Lhd , Pin (F.F.- R.F.) Part No912b060000109 Model 912Lhd , Clamp Half Part No912b060000116 Model 912Lhd , Bonded Seal Part Nosc011/027 Model 912Lhd , Drain Cock, Valve Part Nobp2rve Model 912Lhd , Strainer Part No102135 Model 912Lhd , O Ring Part No103967 Model 912Lhd , Hex Head Bolt Part Nostdb035-10-25 Model 912Lhd , Tank Cap Assembly Part No229334 Model 912Lhd , Hex Head Bolt Part Nostdb035-08-30 Model 912Lhd , Spring Washer Part Nomdw08sa Model 912Lhd , Spring Washer Part Nomdw24sa Model 912Lhd , Hex Head Bolt Part Nostdb035-12-90 Model 912Lhd , Flat Washer Part Nomaw12ga Model 912Lhd , Hex Head Bolt Part Nostdb035-08-80 Model 912Lhd , Hex Nut Part No369-0108 Model 912Lhd , Hex Head Bolt Part Nostdb035-16-160 Model 912Lhd , Hex Nut Part No369-0116 Model 912Lhd , Lock Wire (As Required) Part Nol400 Model 912Lhd , Rear Reflector Part No12wl040000126 Model 912Lhd , Threaded Boss Part No016a000099060 Model 912Lhd , Link Part Noeea0004049 Model 912Lhd , Hex Head Bolt Part Not12gg24 Model 912Lhd , Handle, Operator Part No912a020000557 Model 912Lhd , Hex Head Bolt Part Nostdb035-12-45 Model 912Lhd , Spring Washer Part Now12gf Model 912Lhd , Fuel Level Gauge Part No912b050000314 Model 912Lhd , Fuel Level Guard Part Noeea0025768 Model 912Lhd , Hex Socket Head Cap Screw Part No370-2206 Model 912Lhd , Gasket Part No910a050000068 Model 912Lhd , Cover, Fuel Tank Part No910a020000239 Model 912Lhd , Cover, Battery Part No912a020000897 Model 912Lhd , Pipe Part No912a020000830 Model 912Lhd , Engine Assy (Deutz) Part No912b070000393 Model 912Lhd , Engine (Deutz 90 Kw) Part No912b050000336 Model 912Lhd , Engine Mtg. Front Part No912a020000783 Model 912Lhd , Hex Head Bolt Part Nostdb035-12-110 Model 912Lhd , Nyloc Nut Part No369-0612 Model 912Lhd , Fuel Line (Circuit) Part No912b070000384 Model 912Lhd , Diesel Hose Part No917a050000052 Model 912Lhd , Hollow Screw Part No12wl4195996a Model 912Lhd , Sealing Ring Part No12wl050000087 Model 912Lhd , Banjo Bolt Part No822a050000047 Model 912Lhd , Washer, Banjo Bolt Part No822a050000046 Model 912Lhd , Diesel Hose Part No912a050000371 Model 912Lhd , Fuel Hose Part No12wl050000404 Model 912Lhd , Hose Clamp (Fuel Circuit) Part No12wl050000172 Model 912Lhd , Bracket (Fuel Filter) Part Noeea0033563 Model 912Lhd , Hex Head Screw Part Nomt05lg10g Model 912Lhd , Spring Washer Part Nomdw05sa Model 912Lhd , Banjo Connector Part No12wl050000213 Model 912Lhd , Transmission (912B Mk-Ii) Part No912d050000160 Model 912Lhd , Tube Assy. Part Noeea0013743 Model 912Lhd , O Ring Part Noeea0013082 Model 912Lhd , Tube Clip Part Noeea0019348 Model 912Lhd , Tube Assy. Part Noeea0013741 Model 912Lhd , Tube Slleve Part Noeea0005696 Model 912Lhd , Sleeve Lock Part Noeea0008046 Model 912Lhd , Input Shaft Part Noeea0013744 Model 912Lhd , Output Shaft Front Bearing Part Noeea0005866 Model 912Lhd , Retainer Ring Part Noeea0008035 Model 912Lhd , Gear Part Noeea0013746 Model 912Lhd , Bearing Part Noeea0013745 Model 912Lhd , Output Shaft Oil Seal Part Noeea0005867 Model 912Lhd , Air Breather Part Noeea0005680 Model 912Lhd , Plug Part Noeea0013748 Model 912Lhd , Screen Assy. Gasket Part Noeea0005687 Model 912Lhd , Screw Part Noeea0008056 Model 912Lhd , Screw-Converter Housing Part Noeea0013076 Model 912Lhd , Lock Washer Part Noeea0005685 Model 912Lhd , Screw Part Noeea0008052 Model 912Lhd , Cap Screw Part Noeea0019349 Model 912Lhd , Lock Washer Part Noeea0013742 Model 912Lhd , Sleeve Part Noeea0008045 Model 912Lhd , Trans. Case & Tube Assy. Part Noeea0013750 Model 912Lhd , Clip Part Noeea0013109 Model 912Lhd , Pressure Tube Part Noeea0008060 Model 912Lhd , Rivet Part Noeea0008072 Model 912Lhd , Cap Screw Part Noeea0019350 Model 912Lhd , Washer Part Noeea0013112 Model 912Lhd , O Ring Part Noeea0011654 Model 912Lhd , Tube Part Noeea0011588 Model 912Lhd , Oil Distributor Part Noeea0011609 Model 912Lhd , Dowel Pin Part Noeea0008061 Model 912Lhd , Magnetic Drain Plug Part Noeea0005708 Model 912Lhd , Screen Assembly Part Noeea0005688 Model 912Lhd , Bushing (Not Shown) Part Noeea0013116 Model 912Lhd , Washer-Shim (Not Shown) Part Noeea0013117 Model 912Lhd , O Ring (Not Shown) Part Noeea0019352 Model 912Lhd , Tube Assy. Part Noeea0013110 Model 912Lhd , Oring, Suction Line Part Noeea0005966 Model 912Lhd , Pressure Tube Part Noeea0011587 Model 912Lhd , Cover Part Noeea0013751 Model 912Lhd , Nut Part Noeea0008079 Model 912Lhd , Stud Part Noeea0011561 Model 912Lhd , Pipe Plug Part Noeea0005683 Model 912Lhd , Gear(27T) Part Noeea0013738 Model 912Lhd , Gear-High Range 52T Part Noeea0011585 Model 912Lhd , Gear-Drive Low 4Th. 26T Part Noeea0013737 Model 912Lhd , Group Reverse 3Rd Shaft Part Noeea0019403 Model 912Lhd , Piston Ring Part Noeea0008081 Model 912Lhd , Front Bearing Retaing Ring Part Noeea0005808 Model 912Lhd , Washer Part Noeea0013140 Model 912Lhd , Snap Ring Part Noeea0008084 Model 912Lhd , Retainer Ring Part Noeea0008086 Model 912Lhd , Inner Disc Part Noeea0013144 Model 912Lhd , Assy. Clutch Piston & Seals Part Noeea0019377 Model 912Lhd , Outer Seal Part Noeea0008091 Model 912Lhd , Seal-Clutch Piston Metering Part Noeea0019354 Model 912Lhd , Assy-Clutch Piston & Seals Part Noeea0022169 Model 912Lhd , Retainer Spring Part Noeea0022171 Model 912Lhd , Snap Ring Retainer Part Noeea0008098 Model 912Lhd , Clutch Drive Gear Bearing Part Noeea0005814 Model 912Lhd , Return Spring Part Noeea0008102 Model 912Lhd , Bearing Part Noeea0008104 Model 912Lhd , Snap Ring Part Noeea0008105 Model 912Lhd , Spacer Part Noeea0008106 Model 912Lhd , Shield Out Part Noeea0008107 Model 912Lhd , Rear Bearing Part Noeea0013151 Model 912Lhd , Retainer Ring Part Noeea0008109 Model 912Lhd , Front Bearing Part Noeea0013142 Model 912Lhd , Front Bearing Snap Ring Part Noeea0005809 Model 912Lhd , Clutch Driven Gear Bearing Part Noeea0005811 Model 912Lhd , Spring Retainer Snap Ring Part Noeea0005820 Model 912Lhd , Washer Assy. Part Noeea0013150 Model 912Lhd , Ring Retainer Part Noeea0013162 Model 912Lhd , Sanp Ring Part Noeea0013163 Model 912Lhd , Assy-Fwd & 2Nd Shaft,Hub,Drum & Plug Part Noeea0019356 Model 912Lhd , Seal-Clutch Piston -Outer Part Noeea0022170 Model 912Lhd , Gear-2Nd 30T Part Noeea0011621 Model 912Lhd , Assy-Low Shaft,Hub,Drum & Plug Part Noeea0019357 Model 912Lhd , Assy-Low Hub & Drum Part Noeea0019358 Model 912Lhd , O Ring Part Noeea0013178 Model 912Lhd , Retaining Ring Part Noeea0013175 Model 912Lhd , Shaft Part Noeea0013753 Model 912Lhd , Plug Part Noeea0013179 Model 912Lhd , Assy-Clutch Piston & Seals Part Noeea0019359 Model 912Lhd , Clutch Inner Disc Part Noeea0008115 Model 912Lhd , Spring Part Noeea0013167 Model 912Lhd , Retainer Spring Part Noeea0013168 Model 912Lhd , Bearing Spacer Part Noeea0013170 Model 912Lhd , Spring Retainer Part Noeea0008124 Model 912Lhd , Ring Retainer Part Noeea0013169 Model 912Lhd , Gear(54T) Part Noeea0013752 Model 912Lhd , Bearing Assy. Part Noeea0013171 Model 912Lhd , Pilot Bearing Part Noeea0008130 Model 912Lhd , Bearing Cup Part Noeea0008156 Model 912Lhd , Cap Part Noeea0013756 Model 912Lhd , Screw Part Noeea0008122 Model 912Lhd , Lock Washer Part Noeea0005729 Model 912Lhd , O-Ring Part Noeea0013755 Model 912Lhd , O Ring Part Noeea0005960 Model 912Lhd , Bearing Cup Part Noeea0014098 Model 912Lhd , Bearing Cone Part Noeea0013173 Model 912Lhd , Shim (.004) Part Noeea0013757 Model 912Lhd , Shim (.007) Part Noeea0013758 Model 912Lhd , Shim (.01) Part Noeea0013759 Model 912Lhd , Shim (.02) Part Noeea0013760 Model 912Lhd , Snap Ring Part Noeea0013135 Model 912Lhd , Assy-4Th Hub & Drum Part Noeea0019360 Model 912Lhd , Assy-Idler Shaft,Gear And Plugs Part Noeea0019361 Model 912Lhd , Shaft And Bearing Assy. Part Noeea0013189 Model 912Lhd , Bearing Lock Ball Part Noeea0008138 Model 912Lhd , Locating Ring Part Noeea0008139 Model 912Lhd , Washer Part Noeea0013764 Model 912Lhd , Disc Hub Nut Part Noeea0013224 Model 912Lhd , Gasket Part Noeea0008141 Model 912Lhd , Cap Part Noeea0013765 Model 912Lhd , Ber.Cap Stud Lock Washer Part Noeea0005861 Model 912Lhd , Screw Part Noeea0013766 Model 912Lhd , Clutch Outer Disc Part Noeea0008088 Model 912Lhd , Spring Retainer Part Noeea0008101 Model 912Lhd , Spring Retainer Part Noeea0008103 Model 912Lhd , Snap Ring Part Noeea0011575 Model 912Lhd , Impeller Hub Gear Bearing Part Noeea0005738 Model 912Lhd , Gear-4Th Clutch & Hub 23T Part Noeea0019363 Model 912Lhd , Spacer Part Noeea0011595 Model 912Lhd , Bearing Part Noeea0011566 Model 912Lhd , Piston Ring Part Noeea0008224 Model 912Lhd , Oil Seal Part Noeea0013190 Model 912Lhd , Bearing Cap Part Noeea0008145 Model 912Lhd , Shim (.010) Part Noeea0008148 Model 912Lhd , Shim (.020) Part Noeea0008149 Model 912Lhd , Oring Part Noeea0008150 Model 912Lhd , Bearing Cup Part Noeea0011629 Model 912Lhd , Bearing Cone Part Noeea0013191 Model 912Lhd , Gear Spacer Part Noeea0013192 Model 912Lhd , Output Shaft Part Noeea0013193 Model 912Lhd , O Ring Part Noeea0008157 Model 912Lhd , O Ring Part Noeea0013195 Model 912Lhd , Screw Part Noeea0008160 Model 912Lhd , Screw Part Noeea0008143 Model 912Lhd , Bearing Cap Part Noeea0013088 Model 912Lhd , Gear(38T) Part Noeea0013739 Model 912Lhd , Group-Control Valve Assyy. Part Noeea0022603 Model 912Lhd , Detent Spring Part Noeea0011562 Model 912Lhd , Detent Ball Part Noeea0005905 Model 912Lhd , Assy. -Control Valve Housing Part Noeea0022636 Model 912Lhd , Seal Oil Part Noeea0019381 Model 912Lhd , Retainer Ring Part Noeea0011634 Model 912Lhd , Oil Seal Washer Part Noeea0005990 Model 912Lhd , Fwd & Rev Valve Spool Part Noeea0019379 Model 912Lhd , Switch Part Noeea0013281 Model 912Lhd , Plug Part Noeea0021156 Model 912Lhd , Plug Part Noeea0013217 Model 912Lhd , Pipe Plug Part Noeea0005881 Model 912Lhd , Speed Sel Valve Spool & Plug Part Noeea0019380 Model 912Lhd , Plug Part Noeea0006012 Model 912Lhd , Washer Part Noeea0006013 Model 912Lhd , Screw Part Noeea0011557 Model 912Lhd , Spacer Part Noeea0006002 Model 912Lhd , Valve Spool Part Noeea0011581 Model 912Lhd , Spool Spring Part Noeea0011582 Model 912Lhd , Screw Part Noeea0014100 Model 912Lhd , Plug Part Noeea0013430 Model 912Lhd , Modulated Valve Assy. Part Noeea0008162 Model 912Lhd , O Ring Part Noeea0005912 Model 912Lhd , Accu. Spring Outer Part Noeea0008163 Model 912Lhd , Accu. Spring Inner Part Noeea0008164 Model 912Lhd , Regulator Spring Part Noeea0005914 Model 912Lhd , Gasket, Control Valve Part Noeea0014466 Model 912Lhd , Flange Part Noeea0005872 Model 912Lhd , O-Ring Part Noeea0013736 Model 912Lhd , Nut Part Noeea0013734 Model 912Lhd , Flange Part Noeea0013732 Model 912Lhd , O Ring Part Noeea0013065 Model 912Lhd , Washer Part Noeea0013064 Model 912Lhd , Nut Part Noeea0008140 Model 912Lhd , Seal-Kit For Transmission Part Noeea0023870 Model 912Lhd , Inner Seal Part Noeea0008092 Model 912Lhd , Piston Ring Part Noeea0008227 Model 912Lhd , Outer Clutch Piston Ring Part Noeea0005790 Model 912Lhd , Inner Clutch Piston Seal Part Noeea0005791 Model 912Lhd , Gasket, Cover Part Noeea0010918 Model 912Lhd , O-Ring Part Noeea0014464 Model 912Lhd , Gasket Part Noeea0008075 Model 912Lhd , Gasket Part Noeea0008057 Model 912Lhd , O-Ring Part Noeea0023036 Model 912Lhd , Oil Ring Part Noeea0014477 Model 912Lhd , O Ring Part Noeea0014481 Model 912Lhd , Seal-Oil Part Noeea0023055 Model 912Lhd , Gasket Part Noeea0012193 Model 912Lhd , Gasket Part Noeea0013279 Model 912Lhd , Gasket Part Noeea0023037 Model 912Lhd , Gasket Part Noeea0023039 Model 912Lhd , Gasket Part Noeea0023040 Model 912Lhd , Seal-Oil Part Noeea0023041 Model 912Lhd , Gasket Part Noeea0023051 Model 912Lhd , Gasket Part Noeea0023052 Model 912Lhd , Flange Output (6C) Part Noeea0033418 Model 912Lhd , O-Ring Part Noeea0033419 Model 912Lhd , Washer Part Noeea0033420 Model 912Lhd , Nut (Idler Shaft) Part Noeea0033421 Model 912Lhd , Transmission Mounting Bra Part No912c020000287 Model 912Lhd , Transmission Mounting Bra Part No912c020000288 Model 912Lhd , Nipple Part Nobp6fn32 Model 912Lhd , Rubber Guard-Trans. Part No912a050000242 Model 912Lhd , Dip Stick Part No912a050000080 Model 912Lhd , Pipe Part No912a020000298 Model 912Lhd , Hex Head Bolt Part No912a060000191 Model 912Lhd , Elbow,Std.90 Degree F/F Part Nobp6bl Model 912Lhd , Hex Head Bolt Part No912a060000192 Model 912Lhd , Flat Washer Part Nomaw08ga Model 912Lhd , Torque Converter (912B Mk-Ii) Part No912a050000159 Model 912Lhd , Pressure Regulatingvalve Group Part Noeea0013880 Model 912Lhd , Regulator Valve Assy Part Noeea0013820 Model 912Lhd , Valve Piston Part Noeea0013817 Model 912Lhd , Valve Spring , Inner Part Noeea0008247 Model 912Lhd , Valve Spring Part Noeea0013816 Model 912Lhd , Valve Stop Part Noeea0008243 Model 912Lhd , O Ring Part Noeea0005697 Model 912Lhd , Roll Pin Part Noeea0013815 Model 912Lhd , Safety Valve Seat Part Noeea0013819 Model 912Lhd , Valve Spring Part Noeea0008250 Model 912Lhd , Safety Valve Plunger Part Noeea0013198 Model 912Lhd , Gasket Part Noeea0013818 Model 912Lhd , O Ring, Suction Line Part Noeea0005712 Model 912Lhd , Plug(Not Shown) Part Noeea0013113 Model 912Lhd , Pipe Plug Part Noeea0005682 Model 912Lhd , Impeller To Cover ORing Part Noeea0005972 Model 912Lhd , Screw Part Noeea0013825 Model 912Lhd , Plug(Not Shown) Part Noeea0013118 Model 912Lhd , Bushing Part Noeea0013827 Model 912Lhd , O Ring (Not Shown) Part Noeea0013119 Model 912Lhd , Plug Part Noeea0013826 Model 912Lhd , Impeller Part Noeea0013862 Model 912Lhd , O-Ring Part Noeea0013863 Model 912Lhd , Hub Part Noeea0013864 Model 912Lhd , Bearing Part Noeea0013865 Model 912Lhd , Snap Ring Part Noeea0008265 Model 912Lhd , Spacer Part Noeea0011571 Model 912Lhd , Snap Ring Part Noeea0008268 Model 912Lhd , Retaining Ring Part Noeea0008269 Model 912Lhd , Turbine Hub Part Noeea0008270 Model 912Lhd , Screw Part Noeea0008272 Model 912Lhd , Cap Screw Part Noeea0019390 Model 912Lhd , Snap Ring Part Noeea0008275 Model 912Lhd , Bearing Part Noeea0008276 Model 912Lhd , Screw, Cover Part Noeea0010946 Model 912Lhd , Piston Ring Part Noeea0008278 Model 912Lhd , Sleeve Assy. Part Noeea0013842 Model 912Lhd , Lock Washer Part Noeea0008280 Model 912Lhd , Screw Part Noeea0008281 Model 912Lhd , Snap Ring Part Noeea0013829 Model 912Lhd , Bearing Part Noeea0008283 Model 912Lhd , Gear (28T) Part Noeea0013831 Model 912Lhd , Output Shaft Part Noeea0013832 Model 912Lhd , Ball Bearing Part Noeea0010850 Model 912Lhd , O Ring Part Noeea0013136 Model 912Lhd , Bearing Retainer Part Noeea0013834 Model 912Lhd , Washer Part Noeea0013735 Model 912Lhd , Oil Seal Part Noeea0013838 Model 912Lhd , Stud Part Noeea0013840 Model 912Lhd , Snap Ring Part Noeea0008050 Model 912Lhd , Gear (21T) Part Noeea0013841 Model 912Lhd , Ball Bearing Part Noeea0010887 Model 912Lhd , Piston Ring Part Noeea0008293 Model 912Lhd , Turbine Shaft Part Noeea0008294 Model 912Lhd , Hub Gear Part Noeea0013851 Model 912Lhd , Ring-Span Part Noeea0008296 Model 912Lhd , Charging Pump Sleeve Part Noeea0008297 Model 912Lhd , Gasket Part Noeea0013857 Model 912Lhd , Converter Charging Pump Part Noeea0008299 Model 912Lhd , Stud Part Noeea0013853 Model 912Lhd , Stud Nut Part Noeea0013069 Model 912Lhd , Gear (39T) Part Noeea0013844 Model 912Lhd , Bearing Part Noeea0013845 Model 912Lhd , Spacer Part Noeea0013846 Model 912Lhd , Bearing Part Noeea0013847 Model 912Lhd , Snap Ring Part Noeea0013848 Model 912Lhd , Drive Shaft Part Noeea0013849 Model 912Lhd , Snap Ring Part Noeea0008309 Model 912Lhd , Washer Part Noeea0013850 Model 912Lhd , Pump Adaptor Part Noeea0013858 Model 912Lhd , Stator Support Screw Part Noeea0005728 Model 912Lhd , Group Pump Adaptor Position -A Part Noeea0013887 Model 912Lhd , Pump Adaptor Part Noeea0013855 Model 912Lhd , Screw Part Noeea0013856 Model 912Lhd , Filter Assy. Part Noeea0008213 Model 912Lhd , Filter Element Assy. Part Noeea0023005 Model 912Lhd , Pump Drive Sleeve Snap Ring Assy. Part Noeea0023007 Model 912Lhd , Snap Ring Part Noeea0013814 Model 912Lhd , Seal Kit For Torque Converter Part Noeea0008320i Model 912Lhd , O-Ring Part Noeea0023009 Model 912Lhd , O-Ring Part Noeea0013833 Model 912Lhd , Oil Baffle Seal Part Noeea0008256 Model 912Lhd , Piston Ring Part Noeea0023019 Model 912Lhd , Hex Head Bolt Part Nostdb035-10-55 Model 912Lhd , Engine Stud Part No912a060000210 Model 912Lhd , Hex Nut Part Nomt10lgg Model 912Lhd , Drive Line Assy.(Tc To Trans.) Part No912d050000162 Model 912Lhd , Propeller Shaft (Front) Part No912b050000339 Model 912Lhd , Spring Washer Part Now6gf Model 912Lhd , Hex Head Bolt Part Not6hg32 Model 912Lhd , Pillow Block Bearing Part No912a050000377 Model 912Lhd , Flat Washer Part Nomaw18ga Model 912Lhd , Spring Washer Part Nomdw18sa Model 912Lhd , Hex Head Bolt Part Nostdb035-18-65 Model 912Lhd , Propeller Shaft (Middle) Part No912b050000340 Model 912Lhd , Propeller Shaft (Rear) Part No912b050000341 Model 912Lhd , Front Axle Part No912b050000328 Model 912Lhd , Wheel Nut Part No912a060000204 Model 912Lhd , Axle Bolt Part No910a060000020 Model 912Lhd , Rear Axle Part No912b050000329 Model 912Lhd , Hex Head Bolt Part No912a060000212 Model 912Lhd , Bracket Part No912b020000803 Model 912Lhd , Clamp Half Part No912a020000334 Model 912Lhd , Hex Head Bolt Part Nostdb035-12-55 Model 912Lhd , Hex Nut Part Nomt12lgg Model 912Lhd , Steering Wheel Part No912b070000278 Model 912Lhd , Steering Wheel(41741074A) Part No12wl23103032 Model 912Lhd , Bush, St. Wheel Part No912a060000190 Model 912Lhd , Pipe (Air Intake) Part No912a050000372 Model 912Lhd , T-Bolt Hose Clamp Part No19wl050001351 Model 912Lhd , Hex Head Bolt Part Nostdb035-08-25 Model 912Lhd , Exhaust Module Part No912b070000376 Model 912Lhd , Gasket Part Noeea0028557 Model 912Lhd , Flange Weldment Assy. Part No822b020000091 Model 912Lhd , Catalytic Converter Part No912b050000342 Model 912Lhd , Gasket Part Noeea0033695 Model 912Lhd , Expansion Bellow Assy Part No912b020000849 Model 912Lhd , Flexible Bellow Part No912a050000343 Model 912Lhd , Exhaust Pipe Part No912b050000344 Model 912Lhd , V-Flange Part No822b020000099 Model 912Lhd , Pipe Part No912a050000347 Model 912Lhd , Flange Slotted Part Noeea0033697 Model 912Lhd , Bracket Part No912b020000850 Model 912Lhd , Clamp Part No912b020000419 Model 912Lhd , Flat Washer Part Now5ga Model 912Lhd , Spring Washer. Part Now7gf Model 912Lhd , Hex Head Bolt Part Not7gg20 Model 912Lhd , Heat Insulation Jacket Kit Part No912a050000380 Model 912Lhd , Exhaust Clamp Part No912a050000391 Model 912Lhd , Cooler Group Part No912b070000390 Model 912Lhd , Cooler (Radiator+Cac) Part No912b050000365 Model 912Lhd , Cable Reel Motor Part No611b050000320 Model 912Lhd , Shaft Seal Part Noeea0034480 Model 912Lhd , Spring Washer Part Now8gf Model 912Lhd , Hex Head Bolt Part Not8vg24 Model 912Lhd , Hex Nut Part Not8vg Model 912Lhd , Fan (Radiator+Cac) Part No912b050000363 Model 912Lhd , Hex Head Bolt Part Not4vg20 Model 912Lhd , Spring Washer Part Now4gf Model 912Lhd , Cooler Bracket Part No912b020000840 Model 912Lhd , Bracket Assy Part No912a020000901 Model 912Lhd , Rubber Sheet Part No912a050000373 Model 912Lhd , Pipe ( Cac In) Part No912a050000350 Model 912Lhd , Pipe ( Cac In) Part No912a050000351 Model 912Lhd , Silicon Hose (Cac) Part No912a050000355 Model 912Lhd , T-Bolt Hose Clamp Part No19wl050001411 Model 912Lhd , Pipe ( Cac Out) Part No912a050000352 Model 912Lhd , Silicon Hose (Cac) Part No912a050000369 Model 912Lhd , T-Bolt Hose Clamp Part No907a050000032 Model 912Lhd , Pipe ( Radiator In) Part No912a050000354 Model 912Lhd , Pipe ( Radiator Out) Part No912a050000353 Model 912Lhd , Silicon Hose (Radiator) Part No912a050000370 Model 912Lhd , Hex Head Bolt Part Nostdb035-08-20 Model 912Lhd , Hose Part No19wl050001405 Model 912Lhd , Hose Clip Part Nop8phb Model 912Lhd , Coolant Hose Part Noeea0027287/001 Model 912Lhd , Coolant Hose Part Noeea0027286 Model 912Lhd , Coolant Hose Part Noeea0027287/002 Model 912Lhd , Fuel Hose Clip Part No12wl050000143 Model 912Lhd , Cooler (Hoc+Toc) Part No912b050000366 Model 912Lhd , Fan (Hoc+Toc) Part No912b050000364 Model 912Lhd , Flat Washer Part Nomaw12gag Model 912Lhd , U-Clamp Part No912a020000902 Model 912Lhd , Hex Nut Part No369-0106 Model 912Lhd , Cooler Guard Assy Part No912b070000391 Model 912Lhd , Cooler Guard Fab. Part No912b020000846 Model 912Lhd , Threaded Boss Part No811a060000056 Model 912Lhd , Hex Head Bolt Part Nostdb035-16-40 Model 912Lhd , Flat Washer Part Nomaw16ga Model 912Lhd , Hex Head Bolt Part Nostdb035-12-70 Model 912Lhd , Motor Guard Part No912a020000861 Model 912Lhd , Hex Head Bolt Part Nostdb035-08-40 Model 912Lhd , Hex Head Bolt Part Nostdb035-12-40 Model 912Lhd , Hydraulic Group (Front Tip) Part No912m100000366 Model 912Lhd , Transmission Hyd. Group Part No912c070000229 Model 912Lhd , O Ring Part Nos3306 Model 912Lhd , O Ring Part Nos3312 Model 912Lhd , O Ring Part Nos3316 Model 912Lhd , Swivel Nut Elbow Part Novu10f10e21bs Model 912Lhd , Swivel Nut Elbow Part Novu16f16e21bs Model 912Lhd , Straight Adaptor Part Novu6f6e16as Model 912Lhd , St. Adaptor Part Novu10f8e16as Model 912Lhd , St. Adaptor Part Novu12f12e16as Model 912Lhd , Adaptor Part Novu16f16e16as Model 912Lhd , Adaptor Part Novu16f16e02as Model 912Lhd , Hose Assy. Part Nostdd026/100 Model 912Lhd , Hose Assy. Part Nostdd026/108 Model 912Lhd , Hose Assy. Part Nostdd026/169 Model 912Lhd , Hose Assy. Part Nostdd026/173 Model 912Lhd , Hose Assy. Part Nostdd026/175 Model 912Lhd , Hose Assy. Part Nostdd026/242 Model 912Lhd , Hose Assy. Part Nostdd026/309 Model 912Lhd , Special Fitting Part Noeea0026099 Model 912Lhd , Hyd Fitting Part Novw16fb20 Model 912Lhd , Hex Socket Plug Part Nop1fpc Model 912Lhd , Trans. Control Valve Assy. Part No912b070000230 Model 912Lhd , Control Valve Assy. Part Noeea0014810 Model 912Lhd , Control Valve Mtg.Bracket Part No912b020000571 Model 912Lhd , Lever-Lh,Control Valve Assy. Part No912a020000572 Model 912Lhd , Lever-Rh,Control Valve Assy. Part No912a020000573 Model 912Lhd , Link Part No912a020000564 Model 912Lhd , Link Part No912a020000565 Model 912Lhd , Link (5/16) Part No912a060000174 Model 912Lhd , Pin Part No912a060000197 Model 912Lhd , Bushing Part Nogla12j Model 912Lhd , Pin Part Nohra4 Model 912Lhd , Pin Part Nohra3 Model 912Lhd , Cotter Pin Part Nol101 Model 912Lhd , Hex Head Bolt Part Not6gg12 Model 912Lhd , Flat Washer Part Now12g Model 912Lhd , Cotter Pin Part Nol110 Model 912Lhd , Hex Nut Part Not5hg Model 912Lhd , Handle Part No912a020000649 Model 912Lhd , Hex Socket Csk Head Screw Part No370-3037 Model 912Lhd , Tee Part Novu10f10e01ds Model 912Lhd , Straight Adaptor Part Nose024/429 Model 912Lhd , Special Elbow Part No912a020000477 Model 912Lhd , Adaptor Part Novu12f16e02as Model 912Lhd , Adaptor Part Novu12f16e16as Model 912Lhd , Valve Mounting Bracket Part No912a020000319 Model 912Lhd , Reducer(Bsp-Npt),M/M Part Nosc089/056 Model 912Lhd , Elbow 45 Deg. Part Novu12f12e21cs Model 912Lhd , Tee Assy. Part No912a020000617 Model 912Lhd , Union Tee Part Novu12f12e01ds Model 912Lhd , Tee Part Nop1rt Model 912Lhd , Filter Element Assembly. Part Noeea0008221 Model 912Lhd , Hex Head Bolt Part Not6gg20 Model 912Lhd , St. Adaptor Part Novu10f8e02as Model 912Lhd , Elbow, 90 Degree M/F Part Nose012/022 Model 912Lhd , Hose Assembly Part No623d02584/319 Model 912Lhd , Hose Assy. Part Nostdd026/104 Model 912Lhd , Swivel Nut Branch Tee Part Novu6f6e33ds Model 912Lhd , Straight Adaptor Part Nose024/427 Model 912Lhd , Fitting Part Novu6f2e03bs Model 912Lhd , Adaptor Part Nodta001062-012 Model 912Lhd , Hose Assy. Part Nostdd026/089 Model 912Lhd , St.Swivel Adst.Swivel Adaptor F/F Part Nose012/042 Model 912Lhd , O Ring Part Nos2803 Model 912Lhd , Adaptor Metric/Jic Part Noeea0026098 Model 912Lhd , Service Hyd.Group(Front Tip) Part No912m100000257 Model 912Lhd , Bonded Seal Part Nosc011/016 Model 912Lhd , Bonded Seal Part Nosc011/024 Model 912Lhd , Bonded Seal Part Nosc011/009 Model 912Lhd , Fitting Part Novu6f4e02as Model 912Lhd , Straight Adaptor Part Novu10f10e01as Model 912Lhd , Straight Adaptor Part Nose024/206 Model 912Lhd , Hose Assy. Part Nostdd026/101 Model 912Lhd , Hose Assy. Part Nostdd026/114 Model 912Lhd , Hose Assembly Part No623d02584/283 Model 912Lhd , Hose Assy. Part Nostdd026/310 Model 912Lhd , Hose Assy. Part Nostdd026/319 Model 912Lhd , Hose Assy. Part Nostdd033/037 Model 912Lhd , Hose Assy. Part Nostdd026/240 Model 912Lhd , Hose Clip Part Nop105phb Model 912Lhd , Elbow, Street 90 Degree M/F Part Nobp7blb Model 912Lhd , Stand Pipe Part No625a060000092 Model 912Lhd , Special Elbow Part No912a020000315 Model 912Lhd , Stand Pipe (1 1/4 Bspt) Part No621a000000202 Model 912Lhd , Gauge Adaptor Part No811a060000088 Model 912Lhd , Elbow,Std.90 Degree F/F Part Nobp7bl Model 912Lhd , Standpipe Part No625a000001003 Model 912Lhd , Hose Part No623a01515/006 Model 912Lhd , Hyd.Hose (44 Mm) Part Noeea0009445 Model 912Lhd , Hose Clamp Part Nop10phb Model 912Lhd , Nipple Part Nobp7fna Model 912Lhd , Special Elbow Part Noeea0009295 Model 912Lhd , Hex Head Plug (Bsp) Part Nosc036/002 Model 912Lhd , Hose Assy. Part Nostdd026/306 Model 912Lhd , Hex Head Bolt Part Nostdb035-06-16 Model 912Lhd , Spring Washer Part Nomdw06sa Model 912Lhd , Elbow Part Nose024/232 Model 912Lhd , Hydraulic Pump (Service) Part No912b050000385 Model 912Lhd , Gasket Part No912a050000230 Model 912Lhd , Pressure Filter Part No811a050000182 Model 912Lhd , Filter Element Part Noeea0018438 Model 912Lhd , Service Valve Part No912b050000238 Model 912Lhd , Pilot Vavle Part No912b050000216 Model 912Lhd , Filter Mounting Bracket Part No917a020000087 Model 912Lhd , Hex Head Bolt Part Not8gg24 Model 912Lhd , Hex Head Plug (Bsp) Part Nosc036/008 Model 912Lhd , Hex Head Plug (Bsp) Part Nosc036/009 Model 912Lhd , Bonded Seal Part Nosc011/026 Model 912Lhd , Hose Sleeve Part Noeea0023531 Model 912Lhd , Hose Clamp Part Noeea0018063 Model 912Lhd , Bonded Seal Part Nosc011/033 Model 912Lhd , Hex Bushing Part Nop98 Model 912Lhd , Straight Adaptor, M/M Part Nose012/088 Model 912Lhd , Plug For Qrc Part No625a060000008 Model 912Lhd , Quick Release Coupling Part No625a050000011 Model 912Lhd , Bspp Socket Part No625a050000106 Model 912Lhd , Elbow, 90 Degree M/F Part Nose012/026 Model 912Lhd , Straight Adaptor, M/M Part Nose012/085 Model 912Lhd , Hydraulic Hand Pump Part No611b050000326 Model 912Lhd , Hex Head Bolt Part Nostdb035-10-30 Model 912Lhd , Hex Nut Part No369-0110B Model 912Lhd , Relief Valve Assy. Part No625b050000064 Model 912Lhd , Relief Cartridge Part Noeea0008997 Model 912Lhd , Seal Kit-Relief Valve,(*)Marked Items Part Noeea0009001 Model 912Lhd , Hyd.Hose (51 Mm) Part No625a050000113 Model 912Lhd , Return Line Filter Part Nosc100500205 Model 912Lhd , Filter Element Part Noeea0033330 Model 912Lhd , Straight Adaptor Part Nose024/213 Model 912Lhd , Straight Adaptor Part Nose024/209 Model 912Lhd , Straight Adaptor Part Nose024/219 Model 912Lhd , Hex Head Plug (Bsp) Part Nosc036/006 Model 912Lhd , St. Adaptor Part Nose024/210 Model 912Lhd , St.Swivel Adaptor M/F Part Nose012/063 Model 912Lhd , Port Block Part No625c000000836 Model 912Lhd , Port Block Part Noeea0009305 Model 912Lhd , Straight Adaptor, M/M Part Nose012/106B Model 912Lhd , Hose Assembly Part No623d02584/703 Model 912Lhd , Hose Assly Part No623d02584/708 Model 912Lhd , Reducer, M/M Part Nose012/101 Model 912Lhd , St.Swivel Adst.Swivel Adaptor F/F Part Nose012/048 Model 912Lhd , Hose Assy. Part Nostdd026/266 Model 912Lhd , Tee M/M/M Part Nose012/137 Model 912Lhd , Straight Adaptor Part Nose024/212 Model 912Lhd , Elbow, 90 Degree M/F Part Nose012/028 Model 912Lhd , Reducer, M/M Part Nose012/098 Model 912Lhd , Hose Assembly Part No623d02584/754 Model 912Lhd , Stand Pipe Part No803a000000337 Model 912Lhd , Stud(M8) Part No250a050000021 Model 912Lhd , Reducer, M/M Part Nose012/099 Model 912Lhd , Brake Hyd. Group Part No912b070000262 Model 912Lhd , Straight Adaptor Part Novu8f6e16as Model 912Lhd , Hose Assy. Part Nostdd026/039 Model 912Lhd , Adaptor Part Novu8f8e21cs Model 912Lhd , Hose Assy. Part Nostdd026/047 Model 912Lhd , Hose Assy. Part Nostdd026/051 Model 912Lhd , O Ring Part Nos3304 Model 912Lhd , Straight Adaptor (Unf To Bsp) Part Nose015/303 Model 912Lhd , Tee M/M/M Part Nose012/133 Model 912Lhd , Union Tee Part Novu6f6e01ds Model 912Lhd , Straight Adaptor (Long) Part Novu8f6e22as Model 912Lhd , Hose Assy. Part Nostdd026/283 Model 912Lhd , Tee Piece Assy. Part No813m000000226 Model 912Lhd , Tee M/M/M Part Nose012/131 Model 912Lhd , Hose Assembly Part No623d02584/289 Model 912Lhd , St.Swivel Adaptor M/F Part Nose012/062 Model 912Lhd , Straight Adaptor Part Nose024/222 Model 912Lhd , Hose Assembly Part No623d02584/333 Model 912Lhd , Hose Assy. Part Nostdd026/325 Model 912Lhd , Hose Assembly Part No623d02584/306 Model 912Lhd , Hose Assy. Part Nostdd026/315 Model 912Lhd , 3/2 Way Valve Part No19wl050000655 Model 912Lhd , Piston Accumulator(2 Ltr.) Part No912a050000241 Model 912Lhd , Seal Kit For Piston Accumulator Part Noeea0022044 Model 912Lhd , Sealing Ring Part Noeea0022384 Model 912Lhd , 3 Way Dcv Part No811a050000158 Model 912Lhd , Brake Valve Part No912b050000362 Model 912Lhd , Repair Kit, Brake Valve Part Noeea0025375 Model 912Lhd , Elbow, 135 Degree M/F Part Nose012/002 Model 912Lhd , Hex Head Bolt Part Nostdb035-06-35 Model 912Lhd , Flat Washer Part Nomaw06ga Model 912Lhd , Hose Assy. Part Nostdd026/014 Model 912Lhd , Pressure Reducing Valve Part No611a050000004 Model 912Lhd , Hex Head Bolt Part Nostdb035-10-40 Model 912Lhd , Plug Adaptor Part No109793 Model 912Lhd , Plug Adaptor Part No110516 Model 912Lhd , Hose Assembly Part No623d02584/104 Model 912Lhd , Hex Head Plug (Bsp) Part Nosc036/004 Model 912Lhd , St.Swivel Adst.Swivel Adaptor F/F Part Nose012/044 Model 912Lhd , Straight Adaptor, M/M Part Nose012/084 Model 912Lhd , Hex Head Bolt Part Not8gg16 Model 912Lhd , Threaded Boss Part No625a060000044 Model 912Lhd , Bracket, Pr Valve Part No625b020000362 Model 912Lhd , Reducer, M/M Part Nose012/094 Model 912Lhd , Straight Connector Part Novu6f8e16as Model 912Lhd , Flow Control Valve Part Norb2c050000101 Model 912Lhd , Manifold Block Part No917b060000025 Model 912Lhd , Hyd Fitting Part Novu8f8e16as Model 912Lhd , O Ring Part Nos3308 Model 912Lhd , Hex Socket Head Cap Screw Part No370-2338 Model 912Lhd , Adapter Swivel Part Nose024/428 Model 912Lhd , Hose Assy. Part Nostdd026/179 Model 912Lhd , Straight Adaptor M/M Part Nose024/207 Model 912Lhd , Hose Assembly Part No623d02584/315 Model 912Lhd , Hose Assembly Part No623d02584/033 Model 912Lhd , Hose Assy. Part Nostdd026/025 Model 912Lhd , Hose Assy. Part Nostdd026/065 Model 912Lhd , Hose Assy. Part Nostdd026/031 Model 912Lhd , Pres.Gauge Isolator Valve Part No811a050000013 Model 912Lhd , Bracket, Acc. Charge Vlv Part No912a020000652 Model 912Lhd , Oil Pressure Gauge Part No813b000000185 Model 912Lhd , Hex Head Bolt Part Nostdb035-12-30 Model 912Lhd , Clamp Part No912b020000628 Model 912Lhd , Hose Assy. Part Nostdd026/034 Model 912Lhd , Swivel Tee, 3/4 Part Novu8f8e26ds Model 912Lhd , Straight Adaptor Part Nose024/202 Model 912Lhd , Steering Hyd. Group Part No912m100000259 Model 912Lhd , Stand Pipe Part No623a000001490 Model 912Lhd , Hyd.Hose Part No625a00554/004 Model 912Lhd , Hyd.Hose (32 Mm) Part Noeea0009494 Model 912Lhd , Swivel Elbow,90 Deg. Part Novu12f12e21bs Model 912Lhd , St. Adaptor Part Novu10f12e02as Model 912Lhd , Straight Adaptor Part Nose024/221 Model 912Lhd , Straight Adaptor Part Nose024/208 Model 912Lhd , Special Elbow Part Noeea0009299 Model 912Lhd , Adaptor Part Novu12f12e33ds Model 912Lhd , St. Adaptor Part Novu12f12e02as Model 912Lhd , Straight Adaptor Part Novu12f8e16as Model 912Lhd , Hex Head Bolt Part Not6gg24 Model 912Lhd , Reducer, M/M Part Nose012/095 Model 912Lhd , Straight Adaptor Part Nose024/430 Model 912Lhd , Straight Adaptor Part Nose024/282 Model 912Lhd , Hose Assy. Part Nostdd026/130 Model 912Lhd , Hose Assy. Part Nostdd026/110 Model 912Lhd , Hose Assy. Part Nostdd026/172 Model 912Lhd , Gasket Part No912a050000229 Model 912Lhd , Accumulator Charge Valve Part No912b050000245 Model 912Lhd , Repair Kit Part Noeea0018821 Model 912Lhd , Hydraulic Pump (Str. & Br Part No912b050000069 Model 912Lhd , Orbitrol Steering Valve Part No912a050000384 Model 912Lhd , Steering Column Part No912b050000277 Model 912Lhd , Accumulator (4-Ltr) Part No811a050000191 Model 912Lhd , Seal Kit For (*) Marked Items Part Noeea0019109 Model 912Lhd , O-Ring Part Noeea0022385 Model 912Lhd , Elbow Part No912a050000021 Model 912Lhd , Clamp Part Noeea0019155 Model 912Lhd , Elbow, Street 90 Degree M/F Part Nobp6blb Model 912Lhd , Straight Adaptor Part Nose024/201 Model 912Lhd , Hose Assy Part Nostdd026/073 Model 912Lhd , Swivel Nut Elbow Part Novu6f6e21bs Model 912Lhd , Hex Head Bolt Part Nostdb035-08-100 Model 912Lhd , Hex Nut, Nyloc Part Nomt12ln Model 912Lhd , Bonded Seal Part Nosc011/013 Model 912Lhd , Hex Head Plug (Bsp) Part Nosc036/003 Model 912Lhd , Straight Adaptor Part Nose024/211 Model 912Lhd , Hex Head Bolt Part Not8gg20 Model 912Lhd , Bonded Seal Part Nosc011/006 Model 912Lhd , Straight Adaptor, M/M Part Nose012/082 Model 912Lhd , Reducer, M/M Part Nose012/093 Model 912Lhd , Hose Assembly Part No623d02584/309 Model 912Lhd , St.Swivel Adst.Swivel Adaptor F/F Part Nose012/046 Model 912Lhd , Manifold Block Part No910a050000021 Model 912Lhd , Manifold Block Part Noeea0031939 Model 912Lhd , Solenoid Cartridge Part Noeea0030276 Model 912Lhd , Check Cartridge Part Noeea0030277 Model 912Lhd , Straight Adaptor Part Novu6f12e16as Model 912Lhd , Straight Adaptor Part Nose024/218 Model 912Lhd , Elbow 90 Degree Part Novu8f8e21bs Model 912Lhd , Hose Assy. Part Nostdd026/112 Model 912Lhd , Hose Assy. Part Nostdd026/092 Model 912Lhd , Straight Adaptor Part Nose024/203 Model 912Lhd , Check Valve Part No77728871 Model 912Lhd , Check Valve Part No625a050000111 Model 912Lhd , Swivel Nut Elbow Part Novu16f16e21cs Model 912Lhd , Hyd. Cooler Group Part No912c070000280 Model 912Lhd , Hyd. Pump Part No912b050000358 Model 912Lhd , Gasket Part No907a050000047 Model 912Lhd , Straight Adaptor, M/M Part Nose012/087 Model 912Lhd , Hose Assembly Part No623d02584/400 Model 912Lhd , Reducer, M/M Part Nose012/097 Model 912Lhd , Bonded Seal Part Nosc011/019 Model 912Lhd , Hose Assembly Part No623d02584/175 Model 912Lhd , Hose Assy. Part Nostdd033/041 Model 912Lhd , Hose Assy. Part Nostdd026/314 Model 912Lhd , Elbow, 90 Degree M/F Part Nose012/023 Model 912Lhd , Hose Assy. Part Nostdd026/321 Model 912Lhd , Tee M/M/M Part Nose012/132 Model 912Lhd , Straight Adaptor, M/M Part Nose012/083 Model 912Lhd , Hose Assy. Part Nostdd026/326 Model 912Lhd , Bushing Part Nobp7bb6 Model 912Lhd , Elbow Street, 45 Degree M/F Part Nobp7blc Model 912Lhd , Nipple Part Nobp7fn32 Model 912Lhd , Straight Adaptor, M/M Part Nose012/086 Model 912Lhd , Electric Group Part No912a040000218 Model 912Lhd , 7 Display Part No910b040000044 Model 912Lhd , Connector Kit(Pv780) Part No910a040000045 Model 912Lhd , Starting Switch Part No19wl040000073 Model 912Lhd , Emergency Stop Control Station Part Noeea0028455 Model 912Lhd , Emergency Stop Marker Part Noeea0029991 Model 912Lhd , Emergency Stop Push Button Part Noeea0022291 Model 912Lhd , Timer Part Noeea0020754 Model 912Lhd , Relay Module Part Noepra040000007 Model 912Lhd , Buzzer 24V Dc Part No19wl040000084 Model 912Lhd , Cable End Sleeve Terminal(2.5 Sq.Mm) Part Noeea0030029 Model 912Lhd , Cable End Sleeve Terminal(1.5 Sq.Mm) Part Noeea0030028 Model 912Lhd , Cable End Sleeve Terminal(6 Sq.Mm) Part Noeea0030117 Model 912Lhd , Selector Switch Part Noepra040000001 Model 912Lhd , Selector Switch (3 Pos.) Part No910a040000014 Model 912Lhd , Mecan1905 Part No907b040000001 Model 912Lhd , Push Button - 3 Position Part No116602 Model 912Lhd , Duel Head Lamp Relay(24V) Part Noeea0030031 Model 912Lhd , Led Work Light,45W,Low Beam Part No917a040000021 Model 912Lhd , Led Work Light,45W,Wide Flood Part No917a040000022 Model 912Lhd , Led Beacon Part No917a040000024 Model 912Lhd , Led Flashing Light(Amber) Part No917a040000023 Model 912Lhd , Led Tail Light Part No907a040000018 Model 912Lhd , Led Work Light(15W) Part Nossla040000019 Model 912Lhd , Paired Horn Part No919a002910934 Model 912Lhd , Circuit Breaker, 32A Part Noeea0024825 Model 912Lhd , Circuit Breaker, 6A Part No19wl871050265 Model 912Lhd , Circuit Breaker,10A Part No19wl871050023 Model 912Lhd , Circuit Breaker, 16A Part Noeea0025390 Model 912Lhd , Hyd. Oil Temp Sensor Part No917a040000006 Model 912Lhd , Capacitance Oil Level Switch Part No917a040000026 Model 912Lhd , Multicore Control Cable(2X1.5) Part No907a040000024 Model 912Lhd , Multicore Control Cable(4X1.5) Part No907a040000025 Model 912Lhd , Multicore Control Cable(7X2.5) Part No907a040000022 Model 912Lhd , Multicore Control Cable(18X2.5) Part No907a040000023 Model 912Lhd , Multicore Control Cable For Rc Part No912a040000157 Model 912Lhd , Can Bus Cable Part No907a040000012 Model 912Lhd , Solenoid Connector(Led) Part Noeea0029713 Model 912Lhd , Flexible Wire, 1.5 Sq.Mm, Pink Part Noeea0025274 Model 912Lhd , Flexible Wire, 1.5 Sq.Mm, Blue Part Noeea0025275 Model 912Lhd , Flexible Wire, 1.5 Sq.Mm, Yellow Part Noeea0025276 Model 912Lhd , Flexible Wire, 1.5 Sq.Mm, Green Part Noeea0025277 Model 912Lhd , Flexible Wire, 1.5 Sq.Mm, Violet Part Noeea0025278 Model 912Lhd , Flexible Wire, 1.5 Sq.Mm, Red Part Noeea0025279 Model 912Lhd , Flexible Wire, 1.5 Sq.Mm, Grey Part Noeea0025280 Model 912Lhd , Flexible Wire, 1.5 Sq.Mm, White Part Noeea0025281 Model 912Lhd , Flexible Wire, 1.5 Sq.Mm, Black Part Noeea0025282 Model 912Lhd , Flexible Wire, 2.5 Sq.Mm, Red Part Noeea0025283 Model 912Lhd , Flexible Wire, 6 Sq.Mm, Red Part Noeea0025285 Model 912Lhd , Multi-Level Terminal Part Noeea0029579 Model 912Lhd , Terminal Block(Black) Part Noeea0029389 Model 912Lhd , Terminal End Plate Part Noeea0022455 Model 912Lhd , End Clamps Part Noeea0021276 Model 912Lhd , Terminal Block Part Noeea0028566 Model 912Lhd , Terminal Block(Kut10,Yellow) Part Noeea0029453 Model 912Lhd , Terminal Block(Kut10,Green) Part Noeea0029454 Model 912Lhd , End Plate Part Noeea0028567 Model 912Lhd , Mounting Din Rail Part Noeea0022456 Model 912Lhd , Pressure Switch Part No103483 Model 912Lhd , Reversing Alarm Part Noeea0022223 Model 912Lhd , Interior Light Part No910a040000029 Model 912Lhd , Multicore Control Cable(14X1.5) Part No910a040000043 Model 912Lhd , Flashing Led,Red Part No912a040000216 Model 912Lhd , Contact Block(No) Part Noeea0027986 Model 912Lhd , Contact Block(Nc) Part Noeea0027987 Model 912Lhd , On Delay Timer (Crouzet) Part No910a040000059 Model 912Lhd , Tyre Assy (12X24, Tl) Part No912b070000389 Model 912Lhd , Wheel Rim (M/C) Part No912b020000834 Model 912Lhd , Tyre (12X24), Tl Part No912b050000360 Model 912Lhd , Valve Assy (Tl) Part No912b050000367 Model 912Lhd , Cover & Guard Group Part No912b070000397 Model 912Lhd , Support Bracket Part No912a020000874 Model 912Lhd , Hex Head Bolt Part Nostdb035-20-60 Model 912Lhd , Hex Nut Part No369-0120 Model 912Lhd , Bracket Assy Part No912a020000883 Model 912Lhd , Plate Assy Part No912a020000890 Model 912Lhd , Cover Assy Part No912a020000862 Model 912Lhd , Spring Washer Part Nomdw12sa Model 912Lhd , Flat Washer Part Nomaw10gag Model 912Lhd , Hex Head Bolt Part Nostdb035-10-20 Model 912Lhd , Decal, Transmission Oil Part No912a050000297 Model 912Lhd , Pressure Checking Unit Part No150a050000036 Model 912Lhd , Air Nozzle Part No912a050000147 Model 912Lhd , Misc. Group Part No912a070000399 Model 912Lhd , Fire Extinguisher Part No625a050000110 Model 912Lhd , Drive Screw Part Not1000 Model 912Lhd , Trans. Oil Part No00ea000001198 Model 912Lhd , Hydraulic Oil Part Nod10a050000093 Model 912Lhd , Gear Oil(Axle&Transfer Case) Part No115575 Model 912Lhd , Engine Coolant Part No912a050000375 Model 912Lhd , Engine Oil Part No912a050000376 Model 912Lhd , Centralised Lubrication System (Automatic) Part No917b050000022 Model 912Lhd , Automatic Fire Suprression System Part No907a070000027 Model 912Lhd , Automatic Fire Detection & Supression System Part No19wl050000868 Model 912Lhd , Bracket (Fire System) Part No19wl020000733 Model 912Lhd , Threaded Boss Part No811a020000105 Model 912Lhd , Hex Head Screw Part Nomt08lg16g Model 912Lhd , Spring Washer Part Nomdw08sag Model 912Lhd , Hex Nut Part Nomt08lgg Model 912Lhd , Accumulator Charging Kit Part No811a050000124 Model 912Lhd , Electrical Tools Part No907a050000049 Model 912Lhd , Single Core Wire Rubber Bidding Part Nod06a050000189 Model 912Lhd , Logo-Eimco Elecon(Engine Hood) Part No12wl050000047 Model 912Lhd , Fastner Sealant Part No00ea000001155 Model 912Lhd , Hand Pump Part No917a050000106 Model 912Lhd , E.M Tyre Inflating & Checking Device Lb Part No907a050000064 Model 912Lhd , O Ring Kit Part No917a050000113 Model 912Lhd , Wheel Chock Part No822b050000102 Model 912Lhd , Water In Fuel Sensor Part Noeea0035123 Model 912Lhd , Low Fuel Pressure Sensor Part Noeea0035124 Model 912Lhd , Fuel Supply Pump Part Noeea0035125 Model 912Lhd , Common Rail Repair Kit Part Noeea0035126 Model 912Lhd , Boost Pressure Sensor Part Noeea0035127 Model 912Lhd , Control Unit (Ecu) Part Noeea0035128 Model 912Lhd , Temprature Sensor Part Noeea0035129 Model 912Lhd , Starter Motor Part Noeea0035130 Model 912Lhd , Alternator Part Noeea0035131 Model 912Lhd , Colant Level Switch Part Noeea0035132 Model 912Lhd , Accelerator Pedal Part Noeea0035133 Model 912Lhd , Cranck Shaft Sensor/Cam Shaft Sensor Part Noeea0035134 Model 912Lhd , Oil Pressure Sensor Part Noeea0035135 Model 912Lhd , V-Ribbed Belt Part Noeea0035137 Model 912Lhd , Turbocharger Oil Return Gasket Part Noeea0035140 Model 912Lhd , Turbocharger Gasket Part Noeea0035141 Model 912Lhd , Coupling Part Noeea0034760 Model 912Lhd , Spin-On Oil Filter Part Noeea0030669 Model 912Lhd , Pre Fuel Filter Part Noeea0030670 Model 912Lhd , Spin-On Fuel Filt. Part Noeea0030671 Model 912Lhd , Air Filter Outer Part Noeea0030675 Model 912Lhd , Air Filter Inner Part Noeea0030676 Model 912Lhd , Suction Strainer (40 Mesh) Part No625b050000122 Model 912Lhd , Axle Oil Part No12wl050000144 Model 912Lhd , Belt Tensioner Part Noeea0035138 Model 912Lhd , Turbocharger Part Noeea0035139 Model 912Lhd , Plate Intermediate Part Noeea0005576 Model 912Lhd , Drive Shaft Part Noeea0005555 Model 912Lhd , Axle Bolt Part No912a060000124 Model 912Lhd , Axle Bolt Part No811a060000121 Model 912Lhd , Axle Bolt Part No912a060000140 Model 912Lhd , Pinion Nut Part Noeea0012870 Model 912Lhd , Pilot Bearing Part Noeea0005605 Model 912Lhd , Bearing Set Part Noeea0010499 Model 912Lhd , D/L Assy Part No912b050000205 Model 912Lhd , Wheel Stud Part Noeea0013320 Model 912Lhd , Wheel Nut Part Noeea0005573 Model 912Lhd , Link Assy Part No912m100000250 Model 912Lhd , Pilot Valve Part No912b050000098 Model 912Lhd , Spider Assy Part No811m100000417 Model 912Lhd , High Block Spider Assy Part No912m100000348 Model 912Lhd , Service Brake Cylinder Assy Part Noeea0013682 Model 912Lhd , Tank Relief Cartridge Part No613m000001081 Model 912Lhd , Bearing Set Part Noeea0010500 Model 912Lhd , Oil Seal Part Noeea0005558 Model 912Lhd , Oil Seal Part Noeea0005584 Model 912Lhd , Middle Plate Part Noeea0005577 Model 912Lhd , Spiral Beval Wheel Part Noeea0005590 Model 912Lhd , Drive Line Assy Part No912m100000365 Model 912Lhd , Drive Line Assy Part No912b050000218 Model 912Lhd , Coolant Pump Part Noeea0035136 Model 912Lhd , Combination Air Filter Part Noeea0035424 Model 912Lhd , Gasket For Exhaust Manifold Part Noeea0035849c Model 912Lhd , Connecting Line (Engine-Ecu Harness) Part Noeea0035854c Model 912Lhd , Valve Mechan.Cover Part Noeea0035831c Model 912Lhd , Gasket For Tappet Cover Part Noeea0035828c Model 912Lhd , Screw/Bolt For Tappet Cover Part Noeea0035829c Model 912Lhd , Gasketfor Breathing Line In Tappet Cover Part Noeea0035830c Model 912Lhd , Pipe Clamp Part Noeea0035790c Model 912Lhd , Intake Pipe Part Noeea0035791c Model 912Lhd , Spring Band Clamp Part Noeea0035792c Model 912Lhd , Pre Fuel Filter Part Noeea0026786 Model 912Lhd
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 1
TenderDetail
Loading tenders