View Bid Results For Amr Water Tenders

We found 93 Bid Results related to amr water tenders. You can find Contractor details who won amr water tenders along with contract details in Bid awards announcements section.

Filters
Stage
68
15
10
Tender Publishing Platform
20
73
State / UT
19
42
8
5
5
4
4
3
3
2
2
2
2
2
2
2
2
1
1
1
Contract Value
34
27
22
8
Publish Date
1
0
0
0
0
Sector
13
42
13
12
6
5
4
2
2
2
2
1
1
1
Ownership
4
43
34
12
4
Within keyword
Active filters:
Showing 1–2 of 93 tenders matching your filters
Contract Date: Ref. Documents Contract Value : 5.42 Lakh
Local Bodies No of Bidders 1
2.
Health and Family Welfare #11458390 Technical Bid
Supply Of Printing Items For The Period From 01.06.2026 To 31.03.2026 For The Use In District Hospital,Kollam-A+Ve Book Category 321 “ A–Ve Book Category 323 “ B –Ve Book Category 324 “ B+Ve Book Category 325 “ O+Ve Book Category 326 “ Ab+Ve Book Category 327 “ Ab-Ve Book Category 328 “ O-Ve Book Category 1 200 Pages Coupon Book With Counter Foil 54 Gsm 7 X 14Cm Book Category 2 A Group 100Pages Book Category 3 A+Ve 100Pages Book Category 4 Ab Group 100Pages Book Category 5 Abr Evaluation Sheet 100Sheet 60Gsm Book Category 6 Accident Register Cum Wound Certificate Register-( 100 Certificate Each) Serially Numbered Original, Duplicate, Triplicate 54Gsm Book Category 7 Ambulance/Cremation/Burriel/Embam Certificate 54Gsm Book Category 8 Amr Report Form Type A 70Gsm Book Category 9 Amr Report Form Type B 70Gsm Book Category 10 Amr Report Form Type C 70Gsm Book Category 11 Amr Request Form 70Gsm Book Category12 Angiogram Conscent 100Pages Book Category 13 Anti Rabies Register 100Pages 60Gsm Book Category 14 Application For Disability Certificate 100Pages 54Gsm Book Category 15 Attendance Register 24 Pages 60Gsm Book Category 16 Attendance Register 50 Pages 60Gsm Book Category 17 Audiogram Conscent 100Pages 60Gsm Book Category 18 Audiogram Sheet 100Pages 60Gsm Book Category 19 Audiological Ivaluation Sheet 100Sheet 54Gsm Book Category 20 Authenticity Register(Original & Duplicate/54Gsm Book Category 21 B Group 100Pages Book Category 22 B+Ve 100Pages Book Category 23 Bank Request Slip Binding 100Pages Book Category 24 Bio Chemistry Register 70Gsm Book Category 25 Bio Medical Waste Segregation And Removed Check List 100Pages/Book 60Gsm Book Category 26 Biomedical Waste Audit Cl 100Pages Book Category 27 Biomedical Waste Management Checklist 100Pages 60Gsm Book Category 28 Biomedical Waste Segregation Cl 100Pages 60Gsm Book Category 29 Bleaching Solution Preparation Cl 100Pages 60Gsm Book Category 30 Blood Bag Stickers 100Pages Book Category 31 Blood Bank Cash Book 300Page 60Gsm Book Category 32 Blood Bank Daily Stock Register(Blood And Components) 70Gsm Book Category 324 Blood Bank Issue Register Book Category 33 Blood Grouping Forms 100Pages 70Gsm Book Category 34 Blood Grouping Register Book Category 35 Blood Intent /Returned Form 100Pages 70Gsm Book Category 36 Blood Issue Register 300Page 70Gsm Book Category37 Blood Labels(Sticker Type) A+Ve Category 38 Blood Receiving Register 300Page 70Gsm Book Category 39 Blood Screening Register 300 Page 70Gsm Book Category 40 Blood Spill Kit Daily Check List 100 Page 60Gsm Book Category 41 Blood Spill Management 100Page 60Gsm Book Category 42 Braden Risk Assessment Form 100 Page 70Gsm Book Category 43 Camp Grouping Register 300Pages 70Gsm Book Category 44 Camp Register Category 45 Cancer Case Registry Form 100Pages 70Gsm Book Category 46 Cardiac Cl 100Pages 60Gsm Book Category 47 Cash Book For Medisep 300Pages 70Gsm Book Category 48 Casuality Op Register 300Pages 70Gsm Book Category 49 Cath Lab Register 300Pages 70Gsm Book Category 50 Catheter Associated Urinary Tract Infection Prevention Bundle 100Page60Gsm Book Category 51 Census Report 1000Page Book Category 52 Central Peripheral Line Associated Blood Stream Injection 100Page60Gsm Book Category 54 Certificate Of Collection Of Material Object From The Body Of A Person For Chemical Examination At Fsl Etc (Duplicate ) 100Page 54 Gsm Book Category 55 Certificate Of Drunkenness Register-Serially Numbered 100(Triplicate) Book Category 56 Certificate Of Examination By A Specialist Medical Officer/Team Of Medical Officer Register-Serially Numbered 100 Certificate Each((Original & Duplicate/Triplicate) 54Gsm Book Category 57 Check List For Drinking Water 1000Page Book Category 58 Checklist For Illumination In Hospital 100Page 60Gsm Book Category 59 Checklist For Suction Apparatus 100Page 60Gsm Book Category 60 Checklist For Toilet Bowl Fancet 100Page 60Gsm Book Category 61 Cheetle Forceps Keeping Check List 100Page 60Gsm Book Category 62 Chemical Examination Dna 100Page 60Gsm Book Category 63 Chemo Chart 60Gsm Book Category 64 Chemo Conscent Form 100Page 70Gsm Book Category 323 Chemotherapy Prescription Book Category 65 Cl For After Cleaning Procedure 100Page 60Gsm Book Category 66 Cleaning Cl 100Page 60Gsm Book Category 67 Code Blue Form White 70Gsm Book Category 68 Collection Receipt For Rotary Pay Ward 100Page 60Gsm Book Category 69 Competency Assessment For All Staff 100Page 60Gsm Book Category 70 Component Register Book Category 71 Component Stock Register 300Pages 70Gsm Book Category 72 Compound Cleaning Check List70Gsm Book Category 73 Compound Sweaping Cl 100Nos 70Gsm Book Category 74 Computer Sticker 100Pages Book Category 75 Coridoor Cleaning Check List 70Gsm Book Category76 Counselling Register Book Category 77 Crash Cart Checklist 100Pages 70Gsm Book Category 78 Critical Value Register Book Category 79 Cross Matching Register 300Pages 70Gsm Book Category 80 Ct Request Form 100Pages 54Gsm Book Category 81 Ct Patient Preparation Instructions Forms Book Category 82 Cuff Pressure Monitor Book Category 83 Culture And Sensitivity Request Form(Microbiology) 70Gsm Book Category53 Culture Report Type A Book Category 322 Culture Request Form A4 Book Category 84 Daily Collection Book 300Pages 70Gsm Book Category 85 Death Audit Form 70Gsm Book Category 88 Dialysis Cash Book 300Pages 70Gsm Book Category 87 Dialysis Discharge Slip 100Pages 70Gsm Book Category 89 Dialysis Monthly Census Register 300Pages 70Gsm Book Category 90 Dialysis Patient Hand Book Book Category 91 Dialysis Receipt Book 100 Page(Original & Duplicate) 54Gsm Book Category 92 Dialysis Register 300Pages 70Gsm Book Category 93 Dialysis Transfusion Form 100Pages 70Gsm Book Category 94 Disability Assessment Sheet 100Pages 70Gsm Book Category 95 Discharge Card 100Pages Wraper Book Category 96 Dispensing Register Book 400 Pg Description Attached Book Category 97 Dna Profile,Examination By Fsl 100Pages 70Gsm Book Category 98 Doctors Register Book Category 99 Donor Registers 300Pages 70Gsm Book Category 100 Donor Cards Book Category 101 Donor Forms (A3 Size) 2 Pages Book Category 102 Donor Forms Single Page Book Category 103 Donor Record Register 300Pages 70Gsm Book Category 104 Donor Request Forms 100Pages 70Gsm Book Category 105 Donor Satisfaction Form /Feed Back Form 100Pages 70Gsm Book Category 106 Drinking Water Cl 70Gsm Book Category 107 Drug Administration Chart 100Pages 54Gsm Book Category 108 Echo Form 100Pages 60Gsm Book Category 109 Emergency Medicine Cl 100Pages 70Gsm Book Category 110 Estimation Of Age –Serially Numbered 100 Certificate 70Gsm Book Category 111 Examination Of Survivo Of Sexual Offence. 100Pages 70Gsm Book Category 112 Examination Of Breast Form(Picture Type) 100Pages 70Gsm Book Category 113 Feed Back Form Serially Numbered 100Certificate 70Gsm Book Category 114 Final Opinion As To Cause Of Death Register 300Pagrs 70Gsm Book Category 115 Fire Extinguishers Checklist 100Pages 70Gsm Book Category 116 Form For Monthly Op Details 100Pages 70Gsm Book Category 117 Form For Monthly Patients Admitted Details 100Pages 70Gsm Book Category118 Free Dialysis Form Book Category 119 Free Dialysis Register 300Pages 70Gsm Book Category 120 Freezer Register 300Pages 70Gsm Book Category 121 Freezer Temperature Cl 70Gsm Book Category 122 Frequent Touch Surface Cleaning Checklist 100Pages 70Gsm Book Category 123 General Area Cleaning Checklist 100Pages 70Gsm Book Category 124 General Waste And Waste Removal Cl 100Pages 70Gsm Book Category125 Habit Forming Drug Daily Distribution Register(Description Attached) Book Category 326 Habit Forming Drugs Dispensing Register 400 Pages With Printed Columns Book Category126 Haematology Register 70Gsm Book Category127 Haemodialysis Patient Hand Book Book Category 128 Half Size Register 300Pages 70Gsm Book Category 130 Hand Hygine Audit 70Gsm Book Category 129 Hand Hygine Observation Audit Tool 100Pages 70Gsm Book Category 131 Hand Over Register Book Category 325 Hbcb Master Case File Book Let Book Category 132 Health Card 100Pages Book Category 133 Hematology Register 300Pages 70Gsm Book Category 134 Hfa Request Form 70Gsm Book Category 135 Histo Pathological Examination Specimen 100Pages Book Category 136 Hmc Collection Register New Format 300Pages 70Gsm Book Category 137 Hmcprinted Cash Book New Format With 500 Pages 70Gsm Book Category 138 Hormone Analysis Register 300Pages 70Gsm Book Category 139 Hospital Linen Quality Checklist 100Pages 70Gsm Book Category 140 Idrv Register 300Pages 70Gsm Book Category 141 Incident Reporting Form 100Pages 70Gsm Book Category142 Informed Concent Register Book Category143 Informed Written Conscent For Surgery For Minor Operation Theatre Book Category 144 Initial Assessment Of Nurses Book Category 145 Injection Prevention Bundle 100Pages 70Gsm Book Category 146 Investigation Register 300Pages 70Gsm Book Category 147 Ip Case Sheet Serially Numbered 300/400Pages 70Gsm Book Category 148 Ip Register 300/400 Pages 70Gsm Book Category 149 Ip Register For Mrl(For Registration Of Case Sheet) 300/400Pages 70Gsm Book Category 150 Ip Satisfaction 70Gsm Book Category 151 Issue Register Book Category 152 Kasp Death Audit Form 60Gsm Book Category 153 Lab Requisition Form 100Pages 70Gsm Book Category 154 Label For Object Sent For Chemical Analysis Preserved During Postmortem Examination(Triplicate) 100Pages Book Category 155 Laboratory Report Form 100Pages Book Category 156 Large Register Line 100Pages Book Category 157 Large Register Plain 100Pages Book Category 158 Letter Pad 100Pages Book Category 159 Linen Quality 70Gsm Book Category 160 Linen Quality Cl 100Pages Book Category 161 Log Register Book Category 162 Mact Board Register 300Pages Book Category 163 Mamogram Request 100Pages Book Category 164 Master Register Book Category 165 Master Registers 300Pages Book Category 166 Master Registers Large 70Gsm Book Category 167 Medical Board Register 300Pages Book Category 168 Medicine Slip/Requisition Slip 100Nos Book Category 169 Medisep Cash Distribution Register 300Pages Book Category 170 Mercury Spill Kit Daily Check List 100Nos Book Category 171 Micro Biology Sample Receiving Register 300Pages Book Category 172 Microbiological Surveillance Checklist 100Nos Book Category 173 Mlc Folder 100Nos Book Category 174 Monthly Performance Report For Physiotherapy Unit 100Nos Book Category 175 Monthly Report For Communicable Disease 100Nos Book Category 176 Mortuary Register 300Pages 70Gsm Book Category 177 Mortuary Slip Body Receiving 100Nos Book Category 178 Mrd Ip Register 300Pages 70Gsm Book Category179 Mri Patient Preparation Instructions Forms Book Category 180 Mri Request Form 100Nos Book Category 181 Ncd Clinic Form 100Nos Book Category 181 Ncd Form(Diet) 100Nos Book Category 182 Need Assessment Training Cl For All Staffs 100Nos Book Category183 Neuro Lysing Consent 60Gsm Book Category 184 Nihss(National Institute Of Helath Stroke Scale) 70Gsm Book Category 185 Nominal Register 300Pages Book Category 186 Nominal Register 600 Pages Printed 70Gsm Book Category 187 Numbered 100 Certificate Each Book Category 188 Nurses Records And Reports 100Nos Book Category 189 Nutritional Assessment 100Nos Book Category 190 Nutritional Screening Cl 100Nos Book Category 191 O Group 100Pages Book Category 192 O+Ve 100Pages Book Category 193 Object Sent For Chemical Exam(Form) 100Pages Book Category 194 Oct Request Form 70Gsm Book Category 195 Offence Register-Serially Numbered 100 Certificate Each(Original, Duplicate, Triplicate) Book Category 196 Oncology Op Register 70Gsm Book Category 197 Op Register 300Pages Book Category198 Op Satisfaction 70Gsm Book Category 199 Operation List 100Pages Book Category 200 Operation Register 300Pages Book Category 201 Operative Cl 70Gsm Book Category 202 Ophathal Ascan Book Category203 Ophthalmic Examination Paper Book Category 204 Ophthalmic Preoperative Cl 70Gsm Book Category 205 Ophthalmology Prescription Form 100Pages Book Category 206 Ophthalmology Request Form 70Gsm Book Category 207 Opthalmic Examination Form 70Gsm Book Category 208 Ors Cl 70Gsm Book Category 209 Ot Cleaning Cl 100Pages Book Category 210 Ot Consent Form 100Pages Book Category 211 Oxygen Cylinder Checklist 100Pages Book Category212 Oxygen Monitoring 70Gsm Book Category213 Pac Questionair 54Gsm Book Category 214 Patient Care Equipment Checklist 100Pages Book Category215 Patient Details New Format Book Category 216 Patient Pre-Operative Check List 100Pages Book Category 217 Patients Consent Form Book Category 218 Pay Ward Booking Application Form 100Pages Book Category 219 Pay Ward Visiting Coupon Worth Rs.20/-(With Duplicate) 100Nos Book Category 220 Performa For Recording Dying Declaration By A Medical Practiosioner Register( 100 Certificate Each) Serially Numbered Original, Duplicate, Triplicate Book Category 221 Performance Appraisal Form(A3) 100Pages Book Category 222 Physiatrist Prescription Form 100Pages Book Category 223 Physiotherapy Progress Notes And Treatment Records-Ip 100Pages Book Category 224 Plane Register Book Category 225 Police Intimation Register-Serially Numbered-( 100 Certificate Each) Serially Numbered Original, Duplicate, Triplicate Book Category 226 Postmortem Register 300Pages Book Category 227 Pre Operative Check List 100Pages Book Category 228 Prescribed(Original /Duplicate/Triplicate) 100Pages Book Category 229 Prescription Form For Prosthetics And Orthotic Section 100Pages Book Category 230 Pressure Ulcer Cleaning Chart Book Category 231 Prevention Bundle 100Pages Book Category 232 Printed Dialysis Patient Hand Book Cover Multi 130Gsm Inside 60Gsm Book Category 233 Printed Concent Register 300Pages Book Category 234 Printed Daily Census Register 300Pages Book Category 235 Printed Daily Register 300Pages Book Category 236 Printed Dialysis Ip Register 300Pages Book Category 237 Printed Dialysis Register 300Pages 70Gsm Book Category 238 Printed Dispensing Register 70Gsm Book Category 239 Printed Free Dialysis Register 300Pages 70Gsm Book Category 240 Printed Habit Forming 12Istribution Register 70Gsm Book Category 241 Printed Informed Conscent Register For Dialysis 300Pages70Gsm Book Category 242 Printed Local Purchase And Distribution Register 300 Pages(Triplicate)54Gsm Book Category 243 Printed Monthly Census Register 300Pages Book Category 244 Progress Notes And Doctors’ Orders 100Pages Book Category 245 Rass(Richmond Agitation Sedation Scale 100Pages Book Category 246 Raw Data For Hospital Associated Infection 100Pages Book Category 247 Raw Data Form 100Pages Book Category 248 Receipt Book 100Pages(With Original And Duplicate) Book Category 249 Receipt For Dead Body’S For Postmortem Examination 100Pages Book Category 250 Records Keeping Form 100Pages Book Category251 Referral Audit Form Book Category 252 Referral Out Register 300Pages Book Category 86 Referral Register Book Category 253 Referral Register Book Category 254 Referral Slip 100Pages Book Category 255 Referred In Register 300Pages Book Category256 Refund Voucher Book For Rotary Pay Ward 100Pages Book Category 257 Register For Certificate Of Collection Of Material Objects From The Bodyof 300Pages Book Category 258 Register For Postmortem Detailed Notes-Serially 300Pages Book Category 259 Register For Results 300Pages Book Category 260 Register Of Disability 300Pages Book Category 261 Registration Register 300Pages 70Gsm Book Category 262 Report Of Examination For Estimation Of Age Register-Serially Numbered 100Nos Book Category 263 Report Of Examination Of A Male Accused In Sexual Offence Register-Serially Numbered 100 Certificate Each(Including Potency) (Original, Duplicate, Triplicate) Book Category 264 Report Of Examination Of A Victim Alleged To Have Been Drugged Register-Serially Numbered 100 Certificate Each-(Original & Duplicate, Triplicate) Book Category 265 Report Of Examination Of A Victim Of Unnatural Sexual Offence Register-Serially Numbered 100 Certificate Each(Including Potency) (Original, Duplicate, Triplicate) Book Category 266 Report To Be Forward With Material Object 100Nos Book Category 267 Report To Be Forwarded With Material Object Sent For Chemical Analysis (Reserved During Postmortem Examination Original /Duplicate) 100Nos Book Category 268 Reporting Format For Medico Legal Register Book Category 269 Request Forms Book Category 270 Request For Blood Transfusion Forms Category 271 Request For Mamography Book Category 272 Request For Radiological Examination (Ct) 70Gsm Book Category 273 Request For Radiological Examination (Mri) 70Gsm Book Category 274 Request Radiological Examination As Part Of Estimation Of Age 70Gsm Book Category 275 Requisition Letter For Pathological Examination(Serially Numbered 6Page With Original,Duplicate And Triplicate And Last One Page Consent )Book Let 100Nos Book Category 276 Risk Assessment Cl 100Nos 70Gsm Book Category 277 Rsby/Kasp Form 200Pages 70Gsm Book Category 278 Safe I Register 300Pages 70Gsm Book Category279 Sample Seding Register Book Category 280 Security Cl 100Nos 70Gsm Book Category 281 Serology Register 300Nos 70Gsm Book Category 282 Sharp Injury Incident Reporting Form 100Nos 70Gsm Book Category 283 Ssi Bundle 100Nos 60Gsm Book Category284 Ssi Follow Up Register Book Category 285 Standing Disability Board Assessment Certificate 100Nos 70Gsm Book Category 286 Stay Pass (Punching) 100Nos Book Category 287 Stock Register(Format Enclosed) Serially Numbered 500Pages 70Gsm Book Category 288 Sub Stock Register Mrd 300/400Pages 70Gsm Book Category 289 Surgical Safety Cl 100Nos 70Gsm Book Category 290 Surgical Site Prevention Bundle Book Category 321 Surveillance Report Form A4 Book Category 291 Suspected Adverse Drug Reaction Reporting Form 100Nos 70Gsm Book Category 292 Swass Diary Book Category 293 Temperature And Humidity Checklist 100Nos 70Gsm Book Category 294 Temperature Monitoring Chart 54Gsm Book Category 295 Temperature Monitoring Chart For Refrigerator 100Nos 70Gsm Book Category 296 Tmt Form 100Nos 70Gsm Book Category 297 Toilet Cleaning Checklist 100Nos 70Gsm, Book Category 298 Training Register Book Category 299 Transfusion Reaction Forms 100Nos 70Gsm Book Category 300 Transfusion Reaction Investigation Register 300Pages 70Gsm Book Category 301 Treatment Records For Op Patients 100Nos Book Category 302 Treatment/Discharge Certificate Register-Serially Numbered 100 Certificate Each(Original & Duplicate & Triplicate) 54Gsm Book Category 303 Trolly Cl 100Nos70Gsm Book Category 304 Troponine I Report Form 200 Pages Book 70Gsm Book Category305 Ttd Register Book Category 306 Unknown Register 300Pages 70Gsm Book Category 307 Unnumbered Op Ticket Approximately(Main)7.50 X 10 X 120Gsm 100Each Book Category 308 Unnumbered Casuality Op Ticket 7.50X8X1Gsm 100 Each 70Gsm Book Category 309 Urine Analysis Register 300Pages 70Gsm Book Category 310 Usg Request 100Nos 54Gsm Book Category 311 Vap Bundle 100Nos 54Gsm Book Category 312 Visera Sending Register 300Pages 70Gsm Book Category 313 Visiting Pass Worth Rs.10/- (White Paper) 100 Each 54Gsm Book Category 314 Visual Infusion Phlebitis Score 100Pages Book Category 315 Vital Sign Chart 100Pages 70Gsm Book Category 316 Ward Cleaning Checklist 100Pages 70Gsm Book Category 317 Wash Basin Cleaning Cl 100Pages 70Gsm Book Category 318 Waste Segregation And Removal Cl 100Pages 70Gsm Book Category 319 Who Hand Hygienic Observation Tool Category 320 X Ray Request Form(100 Pages Book) 54Gsm Book
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 5
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
4.
Power #11064901 Technical Bid
Construction Of1 No Ct & 1 No Pt Plinth, Construction Of 600 Mm X 600 Mm And 300 Mm X 300 Mm Cable Trench, Gravel Spreading And Electrical Works For One Incoming Feeder Bay Works At Bangar 33 / 11 Kv Sub-Station Under Raiganj Division.- 1 Dismantling all types of plain cement concrete works, stacking servicable materials at site and removing rubbish as directed within a lead of 75m. Ground floor including roof, upto 150 mm. thick 2 Dismantling R.C. floor, roof, beams etc. including cuting rods and removing rubbish as directed within a lead of 75m including stacking of steel bars.Ground floor including roof 3 Dismantling all types of masonry excepting plain cement concrete reinforced, stacking serviceable materials at site and removing rubbish as directed within a lead of 75m.In ground floor including roof. 4 Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete.Depth of excavation not exceeding 1,500 mm. 5 Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work)With earth obtained from excavation of foundation. 6 Filling in foundation or plinth by silver sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand. (payment to be made onmeasurement of finished quantity) 7 Labour for laying soiling with departmental bricks including carriage of departmental bricks within a lead of 150 metres preparation of bed as necessary with brick joints properly filled in and packed with brick joints properly filled in and packed with local sand or powdered earth and including necessary cushion of similar materials below the soling (and in between layers when more than one layer is used)(a) Single brick flat soling (thickness 75 mm) 8 Single Brick Flat Soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with powdered earth and local joints 9 Cement concrete with graded stone ballast (40 mm size excluding shuttering) In ground floor. With N.B. Variety stone metal. (1:3:6) 10 Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement,if any, in ground floor as per relevant IS codes.River bazree 11 Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips(ii ) River Bazree in g.f 12 25mm to 30mm thick shuttering without staging in foundation etc. 13 25 mm to 30 mm thick wooden shuttering as per decision & direction of Engineer-In-Charge 14 Reinforcement for reinforced concrete work in all sorts of structures including distribution bars stirrups, binders etc. including supply of rods, initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every inter- section, complete as per drawing and direction.For works in foundation, basement and upto roof of ground floor/upto 4m. Tor Steel/Mild steel OTHER MANUFACTURERS NOTSPECIFIED 15 Brick work with 1st class bricks in cement mortar (1:6) In foundation and plinth 16 125mm thick brick work with Ist class bricks in cement mortar (4:1) in gound floor. 17 15 mm thick plaster.with (4: 1) cement mortar 18 Neat cement punning about 1.5mm thick in wall dado, window, sills floor drain etc. Note : Cement 0.152 cu. M per 100 sqm. 19 Applying exterior grade Acrylic primer of approved quality and brand on plastered or concrete surface old or new surface to receive decorative textured (matt finish) or smooth finish acrylic exterior emulsion paint including scrapping and preparing the surface throughly, complete as per manufacturer’s specification and as per direction of the Engineer-in-Charge. One coat a) In G. floor 20 Protective and decorative Acrylic exterior emulsion paint of approved quality, as per manufacturers specification and as per direction of EIC to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer. Normal Acrylic Emulsion. a) Ground floor. (two coat) 21 Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothing surfaces by sand papering etc. (This item is applicable to new work or old work when the original surface has been exposed by removal of old paint.) 22 b) On steel or other metal surface.With super gloss (hi gloss) two coats (with any shade except white ) 23 M.S. works in brackets made from flats, angles, tees etc. to sizes specialy bent, twisted, forged; making holes drilled and fitted to rafter of trusses with necessary bolts, nuts, washer or screws etc. (length of straight not less than 230 mm). 24 Supplying and laying chequered tiles of any shade ...... [Usingcement slurry @ 4.4 kg/Sq.m at back side and @2.4 kg/Sq.m for joint filling] Red Variety 25 mm. thick 25 Supply of 40mm nominal size stone aggregate , from malda town railway yard to banger 33/11 kv substation including loading, carriage, unloading, stacking and Spreading per cum P.O : 5300543685 26 Cleaning and grubbing Road land cleaning and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 mm, removal of stumps of such trees cut ealier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, 27 Labour charges for loading, carrying, spreading from stack at site ofyard thedepartmental stone-aggregate (40mm pure) and consoliadating the same by 100mm thickness evenlyincluding carrying by head-load at both of loading and un-loading point. 28 Erection of Isolator cum LA support structure with supply of all nuts and bolts and LA with foundation base plate 430 X 430 X 8 mm. (PCC 9 mtr 4 nos.) 29 Erection of CT Structure @ 15% of material price 30 Erection of 33 KV, 400 A, centre rorating isolators H.L with E.S @ 15% of material price 31 Erection of 33 KV, 400 A, centre rorating isolators H.L w/oE.S @ 15% of material price 32 Erection of 33 KV, dual core, dual ratio, 400-200/1-1Amp C.Ts for incoming @ 15% of material price (03 nos in 01 set) 33 Laying & jointing of 1.1 KV 4C X 2.5 sq.mm copper control cable with supply of cable lugs, glands, tapes, sockets etc @ 15% of material price 34 Laying & jointing of 1.1 KV 4C X 2.5 sq.mm copper control cable with supply of cable lugs, glands, tapes, sockets etc @ 15% of material price 35 Erection of 42 KV class gapless lightning arrestor @ 15% of material price (03 nos in 01 set) 36 Installation of AC 3 phase 4W (1A) CT/PT operated AMR. Trivector feeder meter for 33 KV substation. 37 Fixing of 33 KV pin insulator with pin 38 Installation of CT junction box @ 15% of material price 39 Earthing of switchyard supplying of all materials and equipments 40 Fixing of Danger board (33 KV & 11 KV) 41 Dismantling of existing PT structure and re-erection of the same to an adjacent location 42 Dismantling of existing PT set and re-erection of the same to an adjacent location 43 Dismantling of existing PT junction box and re-fixing of the same to an adjacent location
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 4
West Bengal View Result →
Contract Date: Ref. Documents Contract Value : 7.05 Lakh
Local Bodies No of Bidders 1
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 1
8.
Power #10447428 Price Bid
Installation Of New Distribution Transformers With Associated Ht & Lt Works For Hostel, Sports Complex, Apartments & Residential Complex At Medical College Kohima - Package Iii - Installation Of 3 Nos. Of New 250 Kva , 11 / 0.415 Kv Distribution Transformer For Hostel, Sports Complex, Apartments & Residential Complex. 2 Gi Steel Tubular Pole Sp-35 3 250 Kva, 11 / 0, 4 Kv Transformer ( Cu Wound ) Raised Rcc Plint / Platform Mounted. Note The Dts Shall Be Of 4 Star And Above Ratings As Per Ipds Specifications. 4 Gichannel 100X50x6 Mm For X Arm, Switch D.O. Etc. ( 2.2 Mtrs Length Weighing 20.24 Kg Each ) ) 5 M.S. Angle 50X50x6 Mm For Dt Lt Bus Bar ( 2.2 Mtr Weighing 10 Kg Each ) 6 Lightning Arrestor, Distribution Class ( 9Kv, 5Ka, 1Ph ) . ( Lamco / Oblum Or Other Superior Brands ) . 7 11 Kv Go Air Break Switch Complete 3-Ph ( Heavy Duty ) ( Yamuna / Rpg / Rm Electricals Make ) 8 11 Kv D.O. Fuse With Operating Rod ( Heavy Duty ) ( Yamuna / Rpg / Rm Electricals Make ) 9 Gi Wire 6 Swg ( 5 Mm Dia ) Weighing 19.2 Kg Per 100 Metre Coil - For Pole Earthing 10 Earthing Materials For Transformer And La 11 I ) Copper Plate 2Ft X2 Ft, 3Mm Thick ( Weighing 11Kg Each ) , For Neutral And Body - 2 Nos 12 I ) Copper Plate 1X1, 3 Mm Thick ( Weighing 3Kg Each ) For La 13 Ii ) Copper Wire 5 Swg For Neutral ( 12 Mtrs ) , Body ( 12 Mtrs ) And La ( 20 Mtrs ) , Weighing 0.204Kg Per Mtr. 14 Iii ) Charcoal - ( 20Kg / Bag ) 15 Iv ) Salt - 50Kg 16 V ) 2 ( 25Mm ) Gi Pipe 3 Mtr ( For Water Recharge / Alternate Electrode ) 17 Dtr Distribution Cubicle For 250 Kva Dtrscomprising Of Following Items And Adequate Cable Ferrules / Glands.I ) Copper / Aluminium Bus Bar ( 4 Nos ) , Ii ) Mccb 320 Amps ( 4 Pole ) For Incomer Conforming To L&T / Schneider Make, Iii ) Amr , Dlms Complaint 3Ph 4 Wire Trivector Ltmeter, 5 Amp Rated Currentconforming To Secure / Genus / L&T Make, Iv ) 3 Ph Ltct ( 4Nos ) 400 / 5 Aenclosed In Metallic Box With Input And Out Put Lugs Terminals Or Butterfly Type For Fitting On Lt Bushing Conforming To Secure Or Other Superior Make, V ) 8 Nos Of 200 Amps Kit Kat For 2 Nos Of Outgoing Feeders ( Heay Duty ) 18 Acsr Weasel Conductor 6 / 2.59Mm + 1 / 2.59 Mm. 19 11 Kv Polymer Pin Insulator Complete With Gi Pin ( Yamuna / Denson / Compag / Rpg Make ) 20 11 Kv Polymer Disc Insulator 70 Kn ( Yamuna / Denson / Compag / Rpg Make ) 21 H / W Fittings For Disc Insulator ( E&S ) 70 Kn, Tension Type 22 Tension Clamp For Acsr Weasel 23 Pg Clamp For Weasel 24 Lt Xlpe Single Core Aluminium Conductorpower Cable Of Kei / Havells / Polycab Make 25 I ) 240 Sqmm ( Al ) For Dtr Lt Bushing To Bus Bar 26 Ii ) 185 Sqmm ( Al ) ( For Bus To Line 2 Ckt ) 27 Iii ) . 150 Sqmm ( Al ) ( For Neutral ) 28 Copper Tubular Terminal Ends / Lugs Heavy Duty ( Dowells Or Other Superior Make ) 29 I ) . 240 Sq. Mm 30 Ii ) 185 Sqmm 31 Iii ) . 150 Sq. Mm 32 Gi M. S. Nuts And Bolts With Ms Washer ( Assorted ) 33 Danger Plate 11Kv 34 Aluminium Tape 35 Pole Double Clamp Of G.I Flat 50X6 Mm 36 Stay Set 19 Mm Dia 1.6 Mts. Length With Stay Rod, Bow, Plate 37 Gi Stay Wire7 / 10 Swg Weighing 43.4 Kg Per 100 Metres Coil 38 Ms Rod Welded Mesh ( 15X2.44 ) For Fencing Of Sub-Station . 39 G. I Pipe 2 For Fencing Post 40 Installation Of 1 Nos. Of New 500 Kva , 11 / 0.415 Kv Distribution Transformer For College. 41 Gi Steel Tubular Pole Sp-35 42 500 Kva, 11 / 0, 4 Kv Transformer ( Cu Wound ) Raised Rcc Plint / Platform Mounted. Note The Dts Shall Be Of 4 Star And Above Ratings As Per Ipds Specifications. 43 Gichannel 100X50x6 Mm For X Arm, Switch D.O. Etc. ( 2.2 Mtrs Length Weighing 20.24 Kg Each ) ) 44 M.S. Angle 50X50x6 Mm For Dt Lt Bus Bar ( 2.2 Mtr Weighing 10 Kg Each ) 45 Lightning Arrestor, Distribution Class ( 9Kv, 5Ka, 1Ph ) . ( Lamco / Oblum Or Other Superior Brands ) . 46 11 Kv Go Air Break Switch Complete 3-Ph ( Heavy Duty ) ( Yamuna / Rpg / Rm Electricals Make ) 47 11 Kv D.O. Fuse With Operating Rod ( Heavy Duty ) ( Yamuna / Rpg / Rm Electricals Make ) 48 Gi Wire 6 Swg ( 5 Mm Dia ) Weighing 19.2 Kg Per 100 Metre Coil - For Earthing 49 Earthing Materials For Transformer And La 50 I ) Copper Plate 2Ft X2 Ft, 3Mm Thick ( Weighing 11Kg Each ) , For Neutral And Body - 2 Nos 51 I ) Copper Plate 1X1, 3 Mm Thick ( Weighing 3Kg Each ) For La 52 Ii ) Copper Wire 5 Swg For Neutral ( 12 Mtrs ) , Body ( 12 Mtrs ) And La ( 20 Mtrs ) , Weighing 0.204Kg Per Mtr. 53 Iii ) Charcoal - ( 20Kg / Bag ) 54 Iv ) Salt - 50Kg 55 V ) 2 ( 25Mm ) Gi Pipe 3 Mtr ( For Water Recharge / Alternate Electrode ) 56 Dtr Distribution Cubicle For 500 Kva Dtrscomprising Of Following Items And Adequate Cable Ferrules / Glands, I ) Copper / Aluminium Bus Bar ( 4 Nos ) , Ii ) Mccb 320 Amps ( 4 Pole ) For Incomer Conforming To L&T / Schneider Make, Iii ) Amr , Dlms Complaint 3Ph 4 Wire Trivector Ltmeter, 5 Amp Rated Currentconforming To Secure / Genus / L&T Make, Iv ) 3 Ph Ltct ( 4Nos ) 400 / 5 Aenclosed In Metallic Box With Input And Out Put Lugs Terminals Or Butterfly Type For Fitting On Lt Bushing Conforming To Secure Or Other Superior Make, V ) 8 Nos Of 200 Amps Kit Kat For 2 Nos Of Outgoing Feeders ( Heay Duty ) 57 Acsr Weasel Conductor 6 / 2.59Mm + 1 / 2.59 Mm. 58 11 Kv Polymer Pin Insulator Complete With Gi Pin ( Yamuna / Denson / Compag / Rpg Make ) 59 11 Kv Polymer Disc Insulator 70 Kn ( Yamuna / Denson / Compag / Rpg Make ) 60 H / W Fittings For Disc Insulator ( E&S ) 70 Kn, Tension Type 61 Tension Clamp For Acsr Weasel 62 Pg Clamp For Weasel 63 Lt Xlpe Single Core Aluminium Conductorpower Cable Of Kei / Havells / Polycab Make 64 I ) 400 Sqmm ( Al ) For Dtr Lt Bushing To Bus Bar 65 Ii ) 300 Sqmm ( Al ) ( For Bus To Line 2 Ckt ) 66 Iii ) . 185 Sqmm ( Al ) ( For Neutral ) 67 Copper Tubular Terminal Ends / Lugs Heavy Duty ( Dowells Or Other Superior Make ) 68 I ) . 400 Sq. Mm 69 Ii ) 300 Sqmm 70 Iii ) . 185 Sq. Mm 71 Gi M. S. Nuts And Bolts With Ms Washer ( Assorted ) 72 Danger Plate 11Kv 73 Aluminium Tape 74 Pole Double Clamp Of G.I Flat 50X6 Mm 75 Stay Set 19 Mm Dia 1.6 Mts. Length With Stay Rod, Bow, Plate 76 Gi Stay Wire7 / 10 Swg Weighing 43.4 Kg Per 100 Metres Coil 77 Ms Rod Welded Mesh ( 15X2.44 ) For Fencing Of Sub-Station . 78 G. I Pipe 2 For Fencing Post 79 Construction Of 1.2 Km New 11Kv Outgoing Feedersfor Power Distribution Of Medical Campus And Connecting 6 Nos Of New Dts. ( 5Dp And 5 Sp Line Specificationof 100M Span Length Each ) 80 Gi Steel Tubular Pole Sp-45 81 Gi Ms Channel 100X50x6mm For Top Cross Arm- 2.2 M Long Weighing 20.24 Kg Each 82 Gi Ms Angle 50X50x6mm - 2.5 M Long Weighing 11.25Kg Eachfor Guard Brackets Dp 5 Nos And For Sp 5 Nos ) 83 Gi Ms Angle 50X50x6mm - 5 M Long Weighing 22.5Kg Each. For Dp Bracing 84 11 Kv Polymer Disc Insulator 70 Kn ( Dp-36Nos + 3 Spare ) . Yamuna / Denson / Rpg / Compag Make 85 H / W Fittings For Disc Insulator ( E&S ) 70 Kn, Tension Type 86 11 Kv Polymer Pin Insulator ( Sp- 15 Nos + 3 Spare ) . Yamuna / Denson / Rpg / Compag Make 87 AscrWeasel Conductor 88 Tension Clamp For Acsr Weasel 89 3 Inch C.I Earthing Pipe Each Of 3.0 Meters Conforming To Relevant Iss 90 G. I. Wire , 8 Swg For Guarding ( 5.71 Kg Per Span ) - For 5 Spans 91 G. I. Wire , 6 Swg For Earthing 92 Ht Stay Set With 11 Kv Guy Insulator 93 Pg Clamp, For Acsr Weasel 94 11Kv Danger Plate 95 Gi Nuts And Bolts Withgi Washer ( Assorted ) Inlcuding 12 Through Bolts For Dp Cross Arms 96 Barbed Wire 97 G.I Stay Wire , 7 / 10 Swg 98 I ) 115 Mm Dia ( Top ) . -Double ( Jam ) Clamp For Dp Cross Armchannel Support And Stay. 99 Ii ) 140 Mm Dia ( Mid ) - Single Clamp For Bracing Support 100 I ) 115 Mm Dia ( Top ) . -Double ( Jam ) Clampfor Stay 101 Ii ) 115 Mm Dia ( Top ) - Single Clamp For Cross Arm Channelsupport 102 Sundries 103 Construction Of 2Km New Lt 3Ph 5 Wire Lt Distibution Line Assocaited With 6 New Dts For Electrification Of Medical Campus ( 20 Sp Line Specificationof 50 M Span Length Each ) 104 Gi Steel Tubular Pole Sp 35 105 Gi Ms Angle 40X40x5mm For Lt Cross Arm - 1.5 M Long Weighing 5.25 Kg Each 106 Pole Clamp Of Gi Flat 50X6 Mm Size For Sp 35 Spstructure 107 I ) 90 Mm Dia ( Top ) - Single Clamp For Cross Arm Support 108 I ) 90 Mm Dia ( Top ) . -Double ( Jam ) Clamp For Shackle Strap And Stay. 109 Lt Pin Insulator ( Porcelain ) With G.I Pin. Aditya Birla / Rashtriya Or Superior Brand 110 Shackel Insulator ( Porcelain ) ( 75X90 ) Mm Aditya Birla / Rashtriya Or Superior Brand 111 Gi Shackle Straps ( D Clamp ) With Bolts 112 Aac Asther Conductor For Phases And Neutral 113 Aac Gnat Conductor For Street Light 114 Gi Nuts & Bolts Assorted With Washer 115 Lt Stay Set ( Galvanised ) 116 Lt Guy Insulator ( Porcelain ) 117 Gi 7 / 12 Swg Stay Wire For Lt Stay Set 118 Led Street Light ( 60W ) Fixtures With Brackets, Supports & Accessories & Pvc Wires ( 2.5 Sqmm ) 119 Construction Of 1.5 Km New Lt 1Ph 2 Wire Lt Line For Compound Lighting ( 20 Sp Line Specificationof 50 M Span Length Each ) 120 Gi Steel Tubular Pole Sp 28 121 Gi Ms Angle 40X40x5mm For Lt Cross Arm - 1.5 M Long Weighing 5.25 Kg Each 122 Pole Clamp Of Gi Flat 50X6 Mm Size For Sp 28 Spstructure 123 I ) 89 Mm Dia ( Top ) - Single Clamp For Cross Arm Support 124 I ) 89 Mm Dia ( Top ) . -Double ( Jam ) Clamp For Shackle Strap And Stay. 125 Lt Pin Insulator ( Porcelain ) With G.I Pin. Aditya Birla / Rashtriya Or Superior Brand 126 Shackel Insulator ( Porcelain ) ( 75X90 ) Mm Aditya Birla / Rashtriya Or Superior Brand 127 Gi Shackle Straps ( D Clamp ) With Bolts 128 Aac Gnat Conductor For Phase And Neutral Of Street Light 129 Gi Nuts & Bolts Assorted With Washer 130 Lt Stay Set ( Galvanised ) 131 Lt Guy Insulator ( Porcelain ) 132 Gi 7 / 12 Swg Stay Wire For Lt Stay Set 133 Led Street Light ( 60W ) Fixtures With Brackets, Supports & Accessories & Pvc Wires ( 2.5 Sqmm )
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
9.
Educational and Research Institute #10372706 Price Bid
Procurement Of Equipment, Instrument, Machineries, Tools Etc. Related To Laboratories Procurement Of Equipment Related To Laboratories And Workshops Of Mechanical Electrical Civil Chemical Engineering And Science Humanities Departments Of Hooghly Institute Of Technology Hooghly-Strain Gauge Trainer Kit - Gauge Factor : 2.1 Maximum Bearable Weight : 500 Gm, Cantilever Material : Stainless Steel, Bridge Configuration : Full Bridge Display : 3½ Or 4 Digit Ledwith User Manual 2 Measurement Of Temperature Using Thermocouple, Rtd, Thermistor, Ad950 - Transducers With Electronic Instrumentation Transducers : Thermocouple ( K - Type ) , Thermocouple ( J - Type ) , Thermistor ( Ntc ) , Rtd ( Pt 100 ) , Semiconductor Sensor ( Lm 335 ) And Semiconductor Sensor ( Ad 590 ) With User Manual 3 Bourdon Tube Type Pressure Gauge - Bourdon Tube Type Pressure Gauge, Pressure Range Upto 10, 000 Psi, Accuracy Upto + / -0.25%, With Pumping System 4 Flow Control System Using Mass Flow Meter, Single Loop Controller And Control Valve - Set Up Should Consist Of ---Mass Flow Meter, Single Loop Controller, Control Valve ( Glove ) , Transmitter Should Be Installed At The Upstream Of Control Valve, Controlling Facility By Controller, Continuous Water Recycling Facility, Table Mounted Set Up Preferable With User Manual 5 A / D & D / A Converter Trainer Kit - Analog To Digital Converter • 8-Bit Descrete Adc • On-Board Signal Generator With Adjustable Amplitude Levels • On-Board Led Bank To Observe Digital Outputs • Power Supply : +5V, ±12V Gnd • Interconnection Is Provided By 2Mm Connectors • Experimental Manual Digital To Analog Converter • 8-Bit Binary Weighted Resistors Dac • 8-Bit Ladder Type D To A Converter • Onboard Switches Are Provided For Digital Pattern Generation • 8-Bit Digital Inputs Ranges From 00 To Ff • Extensive Experimental Manual Is Provided With The Kit 6 8051 Based Advanced Microcontrollertrainer - 8051 Microcontroller Trainer Kit;Based On Intels 8051 Microcontroller 12Mhz With • On Board Power Supply • Rechargeable Ni-Cd Battery • Ascii Keyboard Interface • Programming Interface With Pc • Compiler And Cross Assemblers For Programming In C, • Lcd Display, 8051 Usb Programmer, 16*2 Lcd, Light Sensor Module ( Ldr ) , Tsop Sensor Module, 4*4 Matrix Keypad, Aa 6 Cell Holder, Burge Strip F-F Connectors, • 32 K Or Higheruser Ram. ( Expandable ) • Serial I / O Through 8251 Usart • Parallel I / O Lines Available Through Two 8255 Chips • 3 Channels Of 16 Bit Timer / Counters From 8253. 8254 • Adc & Dac Interface Module • Stepper Motor Interface • Square, Triangular, Staircase Wave Generator Interface Module • Dc Voltage, Current Measurement Interface Module • Zero Crossing Detectors Interface Module • Users’ Guide • Cd - Required Software, Usb Cable, Microcontroller & Its Interfacing Book With Application Projects, Cd - Required Software 7 Microcontroller Development Kit - 8051 Development Kit With Accessories And Software 8 Solar Photovoltaic Cell Characteristics Trainer Kit - 12V Solar Module With Suitable Arrangement Of Halogen Lamps 500W, Digital Dc Voltmeter And Ammeter, Lux Meter And Variable Resistive Loadwith User Manual 9 Flux Meter ( Magnetic ) - Integrating Type Digital Fluxmeter, With 3&Half Digit Digital Display, 4- Ranges Of Measurements Indicating Flux Values From 0.1 Kmt ( Kilo Maxwell Turns ) To 2*105 Kmt 10 Digital Storage Oscilloscope ( 70 Mhz ) Detailed Technical Specifications:- A ) No. Of Channels : 2 Or 4 B ) Bandwidth : 70 Mhz C ) Maximum Input : 400 V ( Peak ) D ) Sample Rate : 2 Gsa / Sec E ) Waveform Update Rate : 400 Waveforms / Sec F ) Memory Depth : 100 Kpts Standard ( Upgradable ) G ) Time Base : 5Nsec / Div. To 50 Sec. / Div H ) Waveform Update Rate: 50, 000 Waveforms / Sec I ) Display : 8.5 Inch Colour Wvga J ) Trigger Modes : Force, Edge, And Video, Pulse Width. K ) Built In Interface : Standard Usb 2.0 High Speed Device 11 Lcr Q Meter - Measuring Inductance ( L ) , Capacitance ( C ) , Resistance ( R ) , Quality Factor ( Q ) And Dissipation Factor ( D ) . With A Basic Accuracy Of 0.25% And Five Digit Display Resolution. 12 Diode And Zener Diode Characteristics Trainer - A Complete System To Study The Diode Characteristics Forward And Reverse Characteristics Experiment Can Be Performed On This Trainer Kit Silicon, Zener And Germanium Diode Are Provided With This System. Inbuilt Ammeter And Voltmeter. Digital Display For Displaying Voltage And Current. Different Test Points With User Manual 13 Experimental Kit For Input / Output Characteristics Of Bjt- One Fixed 12V Power Supply, One Variable Constant Voltage Source And One Constant Current Source For Output Characteristic Of The Transistor. Three Digital Meters On The Panel. One Fixed Frequency Of 1Khz With Variable Amplitude , Bread Board With User Manual 14 Training Kit To Study Of Opamp Characteristics - Specification: 2 No. Variable Dc Power Supply 0-3V / 30Ma, 1 No. Fixed Dc Power Supply 12V1 No. Operational Amplifier Ic 741 & Different Types Of Resistance, Capacitors And One Potentiometer With User Manual 15 Training Kit To Study Of Universal Logic Gates & Applications With Power Supply - • On Panel Gates : 4 Nand Gates ( 7400 ) , 4 Nor Gates ( 7402 ) , 4 And Gates ( 7408 ) , 4 Or Gates ( 7432 ) & 6 Not Gates ( 7404 ) • 5 Nos Of Extra 18 Pin Ic Base Mounted On Panel To Use Different Ics • 5 Logic Input Switches With Led • 5 Logic Output Led • On Panel 5 Sockets Each For +5 V & Gnd • Required Numbers Of Patch With User Manual 16 Training Kit For Study Of Kirchhoff’S Current & Voltage Law- Equipped With Necessary Resistors, Digital Voltmeters, Ammeter And Inbuilt Variable Power Supply 5V & 12V.On Board Test Points To Observe Signals, On Board Schematic Diagram, With User Manual 17 Analog Wattmeter - Clear Rectangular Window With Excellent Visibility, Knife Edge Pointer And Anti Parallax Mirror. Accuracy Class ± 0.5% Of Full Scale Deflection. Dynamometer Type Wattmeters I ) 5-10A, 150-300-600V, Ii ) 10-20A, 150-300-600V. 18 Series Parallel Resonance Of R-L-C Ckt - Kit For Series Parallel Resonance Of R-L-C Ckt: The Set-Up Consist Of Power Supply, Audio Oscillator With Digital Readout, Digital Rms Meters And Different Number Of Inductors ( Smoothly Variable ) , Capacitors, Potentiometer, Ammeter & Voltmeters With User Manual 19 Power Factor Meter ( Single Phase ) - Clear Rectangular Window With Excellent Visibility, Knife Edge Pointer And Anti Parallax Mirror. Accuracy Class ± 0.5% Of Full Scale Deflection. Power Factor Meter- Dynamometer Type Power Factor Meter , 1 Phase , Current Coil Range : 2.5 & 5.0 Amps. ( Dual Range ) , Pressure Coil Range: 150, 300 Volts ( Double Range ) . 20 Power Supply:Dc - • 2X30v-3A, 5V-3A • Constant Voltage & Constant Current Operation • Digital Displays For Voltage & Current • Adjustable Current Limiter • Protection Against Overload & Short Circuit 21 Training Kit For Verification Of A ) Superposition Theorem. B ) Thevenin’S Theorem. C ) Norton’S Theorem. D ) Maximum Power Transfer Theorem. Two Nos. Variable Dc Power Supply. Two Nos. Resistive Potentiometer ( Pot ) . Differnt Values Sets Of Resistances. Digital Dc Voltmeter, Dc Ammeter, Complete Operating Manual, Connecting Wires , Patch Cords, Etc. 22 Ac Distributor Simulator - Transmission Line Trainer Consist Of:- 100 Km X 3 Phase Tx Line Block At The End Of Each Block Short Is Possible All Digital Multifunctional Meters At The Sending & Receiving End, Loading Provision For Total 1Kva – Load Of Variable Separate Inductive, Capacitive & Resistive Load Bank. High Quality Patch Cord And User Manual. 23 Lux Meter - Sensitivity – 1 - 50, 000 Lux Error Percentage + 5%, 4 ½ Digit To 5 ½ Digit Detail Operating Manual Also To Be Supplied 24 Dielectric Strength Test Setup For Transformer Oil - Transformer Oil: Breakdown Voltage : 0-60Kv, Vertical Panel Mounted With Voltmeter, Glass Cover Encapsulated, Test Cup And Gap Measuring Gauge With 10 Liter Of Transformer Oil 25 Digital Insulation Tester , Digital Insulation Tester: 500V, 200Mohm, Portable Type 26 Half Wave & Full Wave Bridge Rectifier Trainer Kit, 1 / 2 Wave, Fullwave ( Centre Tapped & Bridge ) With Filter Ckt With User Manual 27 Experimental Kit For Characteristics Of Zener Diode, Complete Set Should Consist Of All Accessories To Perform The Experiment Using A Zener Diode Fitted On The Printed Boardwith User Manual 28 Experimental Kit For Input / Output Characteristics Of Bjt, Transistor Trainer Kit Consists Of One Fixed 12V Power Supply, Variable Constant Voltage Source And Constant Current Source For Output Characteristic Of The Transistor.Digital Meters On The Panelwith User Manual 29 Experimental Setup For Implementation Of Adder & Subtractor, With Adder ( Half & Full ) & Subtractor ( Half & Full ) Using Basic Gates. Must Have Onboard Input Supply, Display To Show Logic Outputwith User Manual 30 Complete Setup To Implement Encoder, Decoder , Multiplexer And De-Multiplexer With Power Supply, Display Unit, Patch Cords, Necessary Ic And Manuals For Each. 31 A / D & D / A Converter Trainer Kit 8 Bit With Accessories And Manual. 32 Scr Single Phase Half Wave, Full Wave, Fully Controlled Bridge Rectifier / Converter With In-Built Meters And On-Board Power Supplywith User Manual 33 Training Kit For Study Of Vi Characteristic Of Scr, Igbt , With Separate Section For Scr And Igbt Characteristics With In-Built Meters And Led Indicationswith User Manual 34 Scr Firing Circuit, Power Requirement: 230 Vac +10%, 50Hzstandard Accessories:6 Volt / 1 / 4 W Lamp, Patch Chords & Instruction Manual 35 Training Kit For Study Of Vi Characteristic Of Diac, With Proper Heat Sink And Training Manual.Consists Of One No. Diac With Proper Heat Sink.All Components Should Mount On A Screen Printed Pcb Fixed On Acabinets 36 Scr Commutation Circuit, Scr Commutation Circuit Commutation Techniques Used . I ) Class A Ii ) Class B Iii ) Class C Iv ) Class D V ) Class E Vi ) Class F • In Built Ic Based Dc Regulated Fixed Power Supply +12Vdc & Acwith User Manual 37 Electronic Energy Meter, A.C. Single Phase, 2 Wire Solid State ( Static ) Fully Electronic Energy Meter, Accuracy Class 1.0 & Current Rating 5-30 Amp. With Backlit Lcd Display For 240 Volt System Fitted With Pilfer Proof Meter Box. 38 Trainer Kit For Measurement Of Medium Resistance By Wheat Stone Bridgekit Must Have Inbuilt Power Supply, Measurement Range 1 Ohm – 100 Ohm, Having Sensitive Galvanometer With User Manual 39 Trainer Kit For Measurement Of Low Resistance By Kelvins Double Bridge, With Power Supply, Range 1 Microohm -1 Kiloohm, Having Sensitive Galvanometerwith User Manual 40 Earth Tester, Insulation Reslstance Test: More Than 25 Megohms At 500 V Dc Between Electrical Circuit & Containing Case, Display: Led Or Lcd. Dual Ranges: 0 - 10 - 1000 Ohm ( B ) 0 - 5 - 500 Ohm 41 Trainer Kit For Measurement Of Inductance By Anderson Bridgekit Must Have Built In Power Supply, Inbuilt Signal Source, Application Bridge On Screen Printed Front Panel Display, Set Of Unknown Inductance Coil, Variable Resistance, Set Of Capacitance, Audio Null Detector, Patch Cords, Connecting Wires And Head Phone, Complete Operating Manual. 42 Trainer Kit For Measurement Of Capacitance By Schering Bridge Kit Must Have Input Supply 50 Hz Sine Wave, Two Ratio Dial P & Q, Each Having 1, 10, 100, 100 Ohm Coil, 3 Decade Dial, X 0.001 Microfarad, 0.01 Microfarad, 0.1 Microfarad. Having Sensitive Head Phonewith User Manual 43 Tri-Vector Meter 3Ph 4 Wire Lt Ct & 3Ph 3 / 4 Wire Ht Ct / Pt Operated Fully Static Amr Compatible Tri-Vector Energy Meters Dlms Compliant – Category C 44 Trainer Kit For Measurement Oflinear Displacement Bylinear Variable Differential Transformer ( Lvdt ) For Linear Displacement, Type: Spring Loaded Core Type, Configuration: Axial Type Lvdt Full, Actual Displacement: By Micrometer Arrangement Pitch: 1 Mm, Circuit: Ac Excitation Source, Phase Detector & Digital Display, Excitation Source: Sine Wave Of 2 Khz To 5 Khz Variable Frequency And 0 To 5 Or 12V Variable Amplitude, Readout: Digital Display To Measure 0 To + / - 10 Mm, Indicating, Displacement In Millimeters With Core In / Out Indicated By + Sign, Test Points: Instruction Manual 45 Measure Pressure Using Pressure Sensor Kit.Resistive Pressure Transducer With Pressure Of 0-300Mm Hg / 6Psi, Primary Excitation Voltage Of 5V Dc On Board Provided. On-Board 41 / 2 Digital Panel Meter Provided Using Ad7135. Pressure Generation And Monitor Using A Pressure Gauge. Onboard Instrumentation Amplifier Provided With User Manual. 46 Trainer Kit For Op-Amp As Inverter, Non-Inverting Modefront Panel Built With High Class Insulated Printed Circuit Board Sheet With Well Printed Circuits And Symbols. Fuse For Short Circuit Protection. Patch Cords. The Trainer Is Housed In Abs Plastic / Wooden Cabinet.Size Of The Trainer Set 12”X8”. Instruction Manual. 47 Trainer Kit For Op-Amp As Adder, Differentiator And Integrator Instrument Comprises Of Two Dc Regulated Power Supply 0-5V Dc, ±15V Dc, One Meters To Measure Input And Output Voltage & Combination Of Resistance, Capacitors Mounted On Front Panelwith User Manual 48 Convert Digital Data Into Analog Data By Using Analog To Digital Converters And Analog Data Into Digital Data By Digital To Analog Converter Glass Epoxy Smobc Pcb, 8 No. Of Output Led, Wooden Box, Proper Patch Cord With User Mannual.Glass Epoxy Smobc Pcb, 8 No. Of Output Led, Wooden / Metal Enclosure 49 Simulate Differential Protection Scheme For Transformer With Power System Simulation Kit-3-Phase, 415V, 50Hz, Ac Supply. Control Supply : 1-Phase, 230V, 50Hz, Ac Supply. Short Circuit Protection : Hrc Fuses & Mcb. 3-Phase, 3Kva, 415 / 240V, Delta / Star Connected Transformer With Tapings Primary : 0-10-20-100% Secondary - 0-10-20-100% On Each Phase Of Windings, Natural Air Cooled. • Protection Cts : Primary Side Cts 10 / 1A, 5 Va, Cl-1, Wound Primary Typesecondary Side Cts 20 / 0.67A, 5Va, Wound Primary Type. • Fault Simulating Switches : 32A, 2-Pole, On / Off Rotary Switches Are Provided For Creating A ) Line To Ground Fault, B ) Line To Line Fault, C ) Inter-Turn Faultprotective Relays. % Differential Relay Static Type-With Minimum Basic Setting Biased Feature 10%, 20%, 30%, 40%, 50% Setting For Current. Ct Rated 1A Definite Time Over Current Relay • Earth Fault Relay • Aux. Supply To Relay : 110 / 220 V Ac / Dc Educational Bench Model With Schematic Diagram Of The Test Circuit Printed On The Model Test Points & Measurement Points Brought Out & Connected To Terminals, Circuit Setup For Testing Through Interconnections Of Patch Chords With User Manual 50 D.C. Compound Motor ( Open Type ) - 2 Hp- Dc Compound Motor: 2H.P. 1500Rpm, 230V, Open Type For Assemble And Dismantling Of Different Parts Of Stator And Rotor, Commutator, Brush Etc. 51 D. C. Shunt Generator- For O.C.C. Test-Dc Motor:- 2Hp, 1500 Rpm., 220V Dc Generator:- 1Kw, 1500 Rpm, 220V. Necessary Panel To Set Up With Foundation, Voltmeter:0-300V, Ammeter: 0-5A, Ammeter:0-1A, 4-Point Dc Starter. 52 Dc Motor Speed Control System With Power Supply & Motor-Motor 0.5 Hp, Variable Dc ( 0-230V ) Source, Built In Techogenerator, Digital Panel Meter, Power Circuits Of 4 Scrs ( 1200V., 25 A ) I.E. Half Bridge, Facilities Of Studying Torque Speed Characteristics Of Dc Motor, Torque Measurement, Rpm Indicatorwith User Manual 53 Swinburns Test To Compute Efficiency Of Shunt Generator, 1Hp, 220V, 1500Rpm-D.C. Motor:- 2 Hp, 230V, 1500Rpm, Shunt Field. Suitable Panel Withvoltmeter ( 0-300V ) , And Ammeter: 0-1A, Ammeter:0-5A With User Manual & Proper Setup With Foundation 54 Determination Of Equivalent Circuit Parameters Of A Single Phase Transformer By O.C And S.C Test- Transformer: 1 Kva, 230 / 115V, Variac: 0-270V, Panel With Voltmeter: ( 0-50V ) , Voltmeter ( 0-300V ) , Ammeter: 0 -2A, Ammeter:0-10A, Wattmeter: 0-1200W. 55 Compute The Efficiency Of A Single Phase Transformer By Back To Back Test- Complete Set Upwith User Manual: Ac Power Supply 0-230V At 4A ( Optional ) • Operated On Mains Power 230V, 50Hz +10% Digital / Analog Meters: • Voltmeter 2 Nos. ( For Primary And Secondary ) • Ammeter 2Nos. ( For Primary And Secondary ) • Digital Wattmeter 2Nos. 56 Parallel Operation Of Two Single Phase Transformers To Determine The Sharing Of Load Current, Apparent Power And Real Power- Transformer ( 2 Numbers ) : 1 Kva, 230 / 115V, Panel With Voltmeter ( 0-300V / 150V ) , Ammeter: 0-10A, Variable Resistive Load 115V, 10A, Single Phase. 57 Three Phase Transformer With Provision For The Connection In All Vector Groups ( Stardelta, Delta-Star Etc ) - 3-Phase, 1Kva, 415V / 230V, Transformer With Provision For The External Connection Terminals To Perform All Vector Groups ( Star-Delta, Delta-Star Etc. ) . 58 Isolation Transformer - Single Phase, 1Kva , 3Phase , 415V / 230V Isolation Transformer With Provision To Show Its Function And Testing Of It. 59 Tachometer For Speed Measurement-Digital Photo Tachometer • No Contact Rpm Measurement, Wide Measuring Range From 0.5 To 100, 000 Rpm. , Resolution: 0.1 Rpm ( < 1000 Rpm ) . • The Last Value Can Be Stored Into The Memory Automatically & Be Obtained By Pressing Memory Call Button With User Manual 60 4 Point Starter-For Operational Upto 7.5 Hp Dc Motor, 230Vdc. 61 Ac Variac ( Closed Type ) - Single Phase 8A, 0-270V, Rotary Type 62 Clip On Meter-Clip On ( Digital Led Display ) Type Meter Suitable For Measurement Of ( I ) Ac / Dc Current 5 / 10 / 50Amp, With Zero Set Button ( Ii ) Voltage:600Vac / 500Vdc, ( Iii ) Resistance: 0-10Mohms. 63 The Three Phase Squirrel Cage Induction Motor Setup With Various Starters- Complete Panel With Dol, Star-Delta , Auto-Transformer Starter With 2Hp , 3Phase, 415V , 4Pole, 1500Rpm, Squirrel Cage Induction Motor With Suitable Foundation & User Manual 64 Three Phase Squirrel Cage Induction Motor For Direct Load Test To Plot The Various Characteristics-2Hp 3Ph , 415V, 4Pole , 1500Rpm Squirrel Cage Induction Motor With Necessary Panel With Meters , Starter With Suitable Loading Arrangements, Proper Foundation 65 Three Phase Squirrel Cage Induction Motor For No Load And Blocked Rotor Test- 2Hp 3Ph , 415V, 4Pole , 1500Rpm Squirrel Cage Induction Motor With Necessary Panel With Meters , Starter With Suitable Loading Arrangements, Proper Foundation 66 Three Phase Squirrel Cage Induction Motor For Speed Control-Applicable Methods: I ) Auto-Transformer, Ii ) Vvvf. Specification: 2Hp , 3Hp , 415V, 4Pole, 1500 Rpm Three Phase Squirrel Cage Induction Motor With Necessary Panel Meters And Equipments. 67 Three Phase Slip Ring Induction Motor With Necessary Panel, Proper Base Foundation - To Measure The Open Circuit Voltage Ratio Of The Three Phase Slip Ring Induction Motor.Specification: 2Hp , 3Ph , 415V, 4Pole, 1500 Rpm 68 Three Phase Alternator For Oc, Sc And Load Test-3 Kva, 415 V, 1500Rpm, 3-Ph, 50Hz, Alternator Coupled With Dc Motor ( Shunt ) 5Hp, 220 V, 1500Rpm, 4-Point Dc Starter, 3-Phase Variable Resistive Load 220 ( L-L ) , 15A Per Phase, With Necessary Panel, Proper Base Foundation 69 Squirrel Cage 1 Hp, 400V I / M & Stroboscope To Measure Slip- I ) 1Hp, 415V, 3-Ph, 50Hz, 1440 Rpm Squirrel Cage Induction Motor With Loading Arrangement. Ii ) Stroboscope For Frequency 0-6Khz. 70 Three Phase Synchronous Motor-Synchronous Motor:3Hp, 415V, 1500 Rpm, Excitor 220V, Dc Through Slipring, Dc Shunt Generator, 1.5Kw, Rpm, 230V Dc, Regulator Control With Necessary Panel, Proper Base Foundation 71 Synchronization Of 3 Phase Alternators By Synchroscope & 3 Lamp Method-Synchronization Of 3 Phase Alternators: 2- Numbers Of 3 Kva, 415V, 1500Rpm, 3-Ph, 50Hz, Alternator Coupled With 2-Numbers Of Dc Motors ( Shunt ) 5Hp, 230Vdc, 1500Rpm Alongwith Synchronisation Panel With Synchronoscope, 3-Lamps ( With Fuse ) For Lamp Method, Ammeters & Voltmeters For Dc Motors And Alternator, Digital Frequency Meter, Digital Rpm Meter For Dc Motors, 4-Point Dc Starters For Both Motors, 3-Phase Star Connected Variable Resistive Load, 4-Pole Mcb ( S ) & Variable Dc ( With 2-Pole Mcb ) Field Control For Both Alternators. The Whole Set-Up Needs To Be Equiped With Proper Electrical Protection, Base Foundation, Connector Cables, With User Manual, 72 Stepper Motor Controller Trainer-Stepper Motor Controller Trainer Stepper Motor : Motor Type :Unipolar, Torque : 6 Kg-Cm Phase Current : 0.8 Amp. , Stepping Angle : 1.8° / 0.9° Operating Voltage : 12 V Dc Input Pulse : 5V Ttl Compatible, Test Points :20 Gold Plated With User Manual 73 D.C. Servometer Speed Control -Trainer Kit-Kit For D.C. Servometer Speed Control- Position Control Of A 12V, 1A D.C.Gear Motor ( 50 Rpm ) Provision For Positive And Negative Tacho Generator Feedback Tacho Constant: 2V / 1000 Rpm Approximately Calibrated Dials For Reference And Output Position: Resolution 1° Servo-Potentiometers With Full 360°Rotation Microprocessor Based Waveform Capture / Display Card Built-In 3½Digit Dvm For Signal Measurements Built-In Step Signal And Ic Regulated Power Supplies For Electronic Circuits Separate Unit For Motor In A See-Through Cabinet 220V±10%, 50Hz Mains Operation With User Manual 74 Oil Hydraulic Circuit Trainer Unit: Hydraulic Circuit Trainer Unit Consisting Of Standard Components And Accessories For Carrying Out The Study Of Various Hydraulic Components And Hydraulic Circuits Make: Any Nationally Or Internationally Reputed Brand With Iso Certified Manufacturing Company. Brochure / Catalogue Showing Make, Model / Model No. And Also Online Link Of Brochure / Catalogue Should Be Mentioned Along With Delivery And Maintenance Kit & Manuals 75 Pneumatic Trainer Kit With Compressor: Unit Is To Be Provided With Standard Mounting Board ( Modular Type ) With All Trainer Kits. All The Products Are To Be Provided With Suitable “One Touch Fittings / Push-In Fittings”.Make: Any Nationally Or Internationally Reputed Brand With Iso Certified Manufacturing Company. Brochure / Catalogue Showing Make , Model / Model No. And Also Online Link Of Brochure / Catalogue Should Be Mentionedalong With Delivery And Maintenance Kit & Manuals. 2 Hard Copies Of Operation Manual To Be Supplied; Installation, Demonstration And Training Of Faculties Are To Be Given. 76 Air Conditioning Trainer : Standard Specifications To Demonstrate The Basic Functioning Of Air-Conditioning. Make: Any Nationally Or Internationally Reputed Brand With Iso Certified Manufacturing Company. Brochure / Catalogue Showing Make, Model / Model No. And Also Online Link Of Brochure / Catalogue Should Be Mentioned Along With Delivery And Maintenance Kit & Manual. 77 Refrigeration Trainer: Standard Specifications To Demonstrate The Basic Functioning Of Vapour-Compression Cycle. Make: Any Nationally Or Internationally Reputed Brand With Iso Certified Manufacturing Company. Brochure / Catalogue Showing Make, Model / Model No. And Also Online Link Of Brochure / Catalogue Should Be Mentioned Along With Delivery And Maintenance Kit & Manuals. 78 Plug Gauge: Plug Gauge, Dimension: 25.4-0.5 Mm, Make: Any Nationally Or Internationally Reputed Brand With Iso Certified Manufacturing Company. Brochure / Catalogue Showing Make, Model / Model No. And Also Online Link Of Brochure / Catalogue Should Be Mentioned. 79 Refrigerator 190 Lit, Direct-Cool Single Door Refrigerator 80 Analog Rough Balance 0-2 Kg, Pan Shape Rectangle Weight Display Analog 81 Analog Rough Balance 0-5 Kg, Pan Shape Rectangle Weight Display Analog 82 Borosil Burette Fitted With Boroflow, 100Ml 83 Borosil Burette Fitted With Boroflow, 50Ml 84 Borosil Burette Fitted With Boroflow, 25 Ml 85 Borosil 3.3 Glass Beaker With Graduation Marks, 1000Ml 86 Borosil 3.3 Glass Beaker With Graduation Marks, 500Ml 87 Borosil 3.3 Glass Beaker With Graduation Marks, 250 Ml 88 Spylx Burette Stand With Clampboss Head And Rod, Burette Stand With Clampboss Head And Rod 89 Transparent Borosilicate Glass Volumetric Flask, 250 Ml 90 Transparent Borosilicate Glassvolumetric Flask, 500 Ml 91 Borosilglass Rod , Outer Diameter: 7Mm, Length: 205 Mm, Material: Polished 3.3 Borosilicate Glass 92 Test Tube Holder, Material: Wrought Iron, Length: 200 Mm, Maximum Opening: 20 To 25 Mm 93 Spherometer: Minimum Length Of Leg 25 Millimeter, Minimum Diameter Of Leg 4 Millimeter, Pitch Of The Screw 1 Millimeter, High Grade Tool Steel 94 Instrument To Observe The Effects Of Frictions Using Inclined Plane: Consisting Of A Wooden Plane 90X18cm Having Adjustment For Setting The Required Angle Precisely Complete With Frictionless Pulley Linear And Circular Scale Pan A Wheeled Trolley And A Set Of Eight Slide Draws Having Bottom Of Different Materials.Base Board Very Superior Quality Having Thick Teak Wood Base, Fittedwith Glass Plate, Complete With Brass Arc, Leveling Screws Pan , Pulley And Iron N.P Roller Export Quality. Heavy Pattern. 95 Stainless Steel Led Digital Vernier Calliper: Mitutoyo, Made In Japan, Length 6, Vernier Constant 0.01Cm , Made Of Stainless Steel, Measure Internal, External And Height Dimensions , Digital Display 96 Verification Of Kirchoffs Law Kit: Type Of On-Board Meter Available -Analog, Number Of Potentiometers Provided Onboard To Vary Load Resistance -1, Number Of Variable Dc Power Supply Available On Board- 1, Variable Dc Power Supply- 20V, Number Of Led Indicators Available To Indicate Power Input -1, Availability Of Dc Voltmeter Available On Board -Yes, Range Of Dcvoltmeter - 0-30Volt, Availability Of Dc Ammeter On Board- Yes, Range Of Dc Ammeter - 0-50 Ma, Number Of Test Points Provided Onboard To Observe Signals - 14, Necessary Patch Cords Available For Interconnection - Yes, Casing Material - Plastic. Two Round Analog Meters For Voltage & Current Measurement, Components Are Mounted Behind The Panel With Printed Circuit Diagram, Connections Are Brought With 4 Mm Banana Sockets, Instrument Fitted In Highly Shockproof Plastics Box, 4 Mm Patch Cords Are Provided With The Trainer For Interconnections, Student Instruction Manual Will Be Provided With The Trainer Kit, 97 Instrument To Verify Inverse Square Law Of Radiation Using Photoelectric Effect: Type Of Display For On-Board Measurement- Digital, Availability Of Dc Voltmeter On Board - Yes, Range Of Dc Voltmeter - 0-20Volt, Availability Of Dc Ammeter On Board - Yes, Range Of Dc Ammeter - 0-100 Ma, Number Of Dc Regulated Power Supply With Short Circuit And Overload Protection-2, Voltage Range Of Continously Variable Dc Power Supply -20 Volt, Number Of Potentiometers Provided Onboard - 1, Number Of Test Points Provided In The Circuit To Observe Voltage And Current Signal - 5, On Board Schematic Diagram - Yes, Casing Material-Plastic, Number Of Led Indicators Available To Indicate Power Input - 1, Provision Of On-Board Knob For Adjusting The Voltage - Yes.Wooden Optical Bench, Photocell Housed With Red And Black Sockets, Lamp House With Lamps, Dc Microammeter. On Board Analog Moving Coil Meters , Galvanometer : 30-0-30, Selenium Photocell Mounted In The Metal Box With Metal Base, Lamp Holder With 60-Watt Bulb With Metal Base, Weight : 1.0Kg Approx.Standard Accessories : Selenium Photocell Mounted In The Metal Box, Wooden Plank With Half-Meter Scale Fitted On It, Lamp Holder With Lamp, Patch Chords, Instruction Manual, 98 Conversion Of Galvanometer Into Ammeter Kit: Type Of On-Board Meter Available -Analog, Number Of Potentiometers Provided Onboard To Vary Load Resistance - 1, Number Of Variable Dc Power Supply Available On Board - 1, Number Of Led Indicators Available To Indicate Power Input - 1, Availability Of Dc Voltmeter Available On Board - Yes, Availability Of Dc Ammeter On Board-Yes, Necessary Patch Cords Available For Interconnection-Yes, Casing Material - Plastic.Instrument Comprises Of Dc Regulated Power Supply Of 0-5V. Three Round Moving Coil Meters ( One Voltmeter, One Milliammeter & One Galvanometer ) . Three Shunts, Three Resistances Are Mounted On Front Panel. 99 Conversion Of Galvanometer Into Voltmeter Kit:Type Of On-Board Meter Available -Analog, Number Of Potentiometers Provided Onboard To Vary Load Resistance - 1, Number Of Variable Dc Power Supply Available On Board - 1, Number Of Led Indicators Available To Indicate Power Input - 1, Availability Of Dc Voltmeter Available On Board - Yes, Availability Of Dc Ammeter On Board-Yes, Necessary Patch Cords Available For Interconnection-Yes, Casing Material - Plastic.Instrument Comprises Of Dc Regulated Power Supply Of 0-5V. Three Round Moving Coil Meters ( One Voltmeter, One Milliammeter & One Galvanometer ) . Three Shunts, Three Resistances Are Mounted On Front Panel. 100 Ohms Law Kit: Type Of On-Board Meter Available -Analog, Number Of Potentiometers Provided Onboard To Vary Load Resistance- 1, Number Of Variable Dc Power Supply Available On Board- 1, Variable Dc Power Supply- 5 Volt, Number Of Led Indicators Available To Indicate Power Input - 1, Availability Of Dc Voltmeter Available On Board -Yes, Availability Of Dc Ammeter On Board - Yes, Casing Material - Plastic.Ohms Law App: To Verify The Ohms Law: Fitted With Slidingrheostat.Onedcvoltmeter, Mo.65&Onedcammetermo-65, Mounted On The Same Base With Terminals, 4 Mm Patch Cords Are Provided With The Trainer Kit For Interconnections 101 Pn Junction Diode Characteristics Kit: Compleate Set With Inbuilt Power Supply & With Digital Voltmeter & Ammeter Compatible For Both Forward & Reverse Bias 102 Boyles Law Apparatus: Burrete Graduated In Cc ( Or Ml ) With 1.0 Cc / Div. Scale Graduated On Both Sides ( Left & Right ) With Same Marking. Both Open And Closed Tubes Can Be Slided Up And Down Over Aluminium Rod. High Quality Synthetic Tube ( 1.0 M Long ) . One Spare Synthetic Tube. ( Withextra 500Gm Mercury ) . Superiorquality, Open&Closedtypeonemeterlongteakwoodboard Onheavy Metal Base Fitted With Leveling Screws Without Mercury But Complete With Pressure Rubber Tubing & Glass Tubes, Routinequality, Doublerodwithopen& Closedendtubes&Pressuretubing. 103 Instrument To Determine The Moment Of Inertia Of A Flywheel About Its Own Axis Of Rotation: Good Quality Stainless Steel Full Setup.Csi Superiorquality Flywheel With Weights , Comprising Of Carefully Machined And Balanced Cast Iron Wheel And Steel Spindle Is Supported On Ball Bearings In Strong Iron Brackets, Thickness: 4.4 Cm, Diameter :20 Cm, Wall Type With Pointer, With Revolution Counter, Set Ofslotted Weights For Flywheel Complete With Weights Cord And Hook. 104 Instrument For Determination Of Spring Constant Of Horizontal & Vertical Spiral Spring Setup: Stand With Heavy Base, Transparent Scale With Mm Resolution, Horizontal Support For Spring, Brightly Colored Stretch Indicator, Three Springs With Identical Diameter And Length, But Different Spring Constants, Three Of Each Spring Included, For A Total Of Nine Springs: Spring Constants Are 5 N / M, 8 N / M, 70 N / M.Consisting Of 45Cm Long Mirrorscale, Spring, Slotted Weights With Hanger And Pointer, Complete On Heavy Tripod Stand, On Metal Stand With Mirror Scale, Superior On Heavy Base, About 50 Cm High For Taking More Readings, Complete With Weights, Helical Spring: Light Spiral Spring With Pointer, Easy To Work With 50 Gm.Weight Complete With Hook For Hanging 105 Stainless Steel Led Digital Outside Micrometer: Mitutoyo: Made In Japan, 0.25Mm-0.01Mm, Least Count 0.01Mm, Made Of Stainless Steel, Digital Display. 106 Linear Expansion Coefficient Apparatus:- Superiorquality , Height 50 Cm, With Brass Rod, Stainlesssteel Finish A 50 Cm Long Expansion Base With A Built-In Dial Gauge And Thermistor.Three Metal Tubes — Brass, Copper ( 99.5%Cu, 0.5% Te ) , And Aluminum ( 98.9% Al, 0.7% Mg, 0.4% Si ) : 6.4 Mm Outside Diameter. A Foam Insulator To Avoid Heat Loss At The Thermistor Connection Point.Thermoplastic Elastometer Tubing With 6.4 Mm I.D.A Source Of Steam Or Hot Water, Such As The Pasco Model Td-8556A Steam Generator.A Digital Ohmmeter Such As Pasco Model Se9589 To Measure The Thermistor Resistance. Leads Should Have Banana Plug Connectors, Such As Pasco Model Se-9750 Or Se-9751 Patch Cords 107 Gclamp-4 Inchirwin 4 Inch / 100 Mm Record H / D G-Clamp T1204 108 Post Office Box-Post Office Box Of Material-Brass And Coil Manganin, Any Nationally Or Internationally Reputed Brand With Iso Certified Manufacturing 109 Muffle Furnace-Voltage ~230 V Ac, Insulating Maximum Temperatures 1000 C / 1200 C & Working Temperature 930 C / 1130 C Controlled By Digital Temperature Controller Cum Indicator 110 Digital Conductivity Meter-Electrode : Cell K = 1 – Pvc Sleeved Power Required: 230 V Ac 10%, 50 Hz, 5 Va Or 9 V Battery Standard Conductance: Conductance Of 1.000 M Stirrer Speed: 200 Rpm 111 Redwood Viscometer No.1-Material Stainless Steel Voltage 220 Volt Power Source Electric Frequency 50 Hz Phase Single Phase Accuracy + / - 3 °C Readability + / - 0. 5 Degree Capacity 50 Ml 112 Flash Point Apparatus With Stirrer-Voltage-115 V / 230 V, 50 Hz / 60 Hz Measuring Range- Up To 110 °C 113 Daniel Cell-Copper Vessel Complete With Porous Pot & Zinc Rod Diameter ~ 3.5- 4 Inch 114 Digital Voltmeter-Voltage -50-500 V Ac Accuracy ±10% 115 Arsenic Detection Kit-Reaction Time: 10 Minutes Test Type: Test Strip Colour Comparison Results Duration: Rapid 116 Digital Ph Meter-Resolution: 0.01 Ph Range: 0.0 To 14.0 Ph Temperature Controller Display 3 Digit 117 Cube Mould ( 70.6 Mm ) These Are Used For Casting Cement Mortar Test Specimens For Carrying Out Compressive Strength Test Of Cement As Per Is:516. These Moulds Are Manufactured As Per Is Specifications. The Faces Are Machined Flat Within ±0.02 Mm Tolerance And The Inside Dimensions Are Accurate Within ±0.2Mm. Each Mould Is Supplied With A Base Plate. Mould, Steel, For 70.6Mm Cube As Per Is: 10080-1982 Weight: Must Be 6.5 Kg Or More. Should Be Isi Mark. These Cube Moulds Are Made Of Steel. The Tolerance Between Faces Is Maintained At ±0.1 Mm And Plainness Is +0.03Mm. Cube Moulds Carry Isi Mark 118 Digital Rebound Hammer With Calibraton Anvil ( For Concrete Compressive Strength Analysis In The Field And Material Hardness Testing. ) Should Come With Rechargeable Batteries Including Charger. Capabality Of On-Board Data Storage And Transfer To A Personal Computer For Further Analysis. Should Conform To Astm C-805, En 12 504-2, Bs -1881- 202 And Other International Standards. Range:10 To 70N / Mm2 Impact Energy: 2.207 N-M Additionally The Following Minimum Specifications Must Be Met. Should Features 16 Character Digital Read Out And Provide Automatic Calculation Of Mean Rebound Number, Compressive Strength And The Median. Should Come With Rechargeable Batteries Including Charger. Capability Of On-Board Data Storage And Transfer To A Personal Computer For Further Analysis Is Required. The Necessary Software And The Required Cables For Connecting To The Computer Should Be Provided. A Calibration Anvil Should Be Provided 119 Ductility Testing Apparatus: Ductility Testing Machine Is: 1208 -1978 For Determining The Ductility Of Asphaltic Bitumen, Native Asphalt, Cut Back Bitumen And Blown Type Bitumen. It Consists Of Three Mould Assemblies On A Base Plate. A Separate Briquette Mould ( Total Length 75 ± 0.5 Mm, Distance Between Clips 30 ± 0.3 Mm, Width At Mount Of Slip 20 ± 0.2 Mm, Width At Minimum Cross Section 10 ± 0.1 Mm, Thickness Throughout 10 ± 0.1 Mm ) For Casting The Specimens Is Also Supplied. A Water Bath Of 10 Litres Capacity With A Perforated Shelf Not Less Than 50 Mm From The Bottom Of Bath And A Thermostat Controller For Heater. The Machine Has Two Standard Rates Of Travel Of 1 Cm / Mnt And 5 Cm / Mnt. The Movable Bracket Can Be Arrested Or Released Without Switching Off The Motor By A Clutch Arrangement. Suitable For Operation On 220V, 50 Hz, Single Phase Ac Supply. 120 Length Gauge Conforms To Is:2386 ( Part-I ) Used For Determination Of Elongation Index Of Aggregate. Length Gauge With Isi Certification Mark Is:2386 ( Part I ) , It Consists Of A Metal Plate On Which 8 Steel Pins Are Vertically Mounted With Specified Distances In Between. This Assembly Is Mounted On A Hardwood Base 121 Colorimeter ( Digital ) : Colorimeter, Equipped With Easy-To-Use Conventional Style Controls, Making It Ideal For Routine And Educational Use. Standard 10Mm Square Cuvettes, Semi-Micro Volume Cuvettes, Flowthrough Or Pour In / Suck Out Cells Can All Be Used With The Standard Sample Holder. Wavelength Range: 400 To 710Nm Wavelength Selection :: 8 In-Built Gelatin Filters: 430, 470, 490, 520, 540, 580, 600 And 710Nm Measurement Ranges:: 0-100%T, 0-1.50Abs, 0.1 To 1000 Concentration Bandwidth:Typically 40Nm Blank Drift:: 2% / Hr After 15 Minute Warm-Up Photometric Linearity :: 1%T Light Source :: Tungsten Filament Lamp Output:: Analogue, 10Mv Per Digit Power: 230V, 50Hz Size ( L X W X D ) :: 300 X 355 X 120Mm Weight:: 3Kg 122 Cod Test Apparatus: Cod Test Sample For Dry Bath Heating. Temperature 5+ 150 ◦C + / _ 1◦ C. Digital Controller With Heating Block. Sample Being Digested Within 2 Hours With Titration Method Bod Bottle Capacity : 300 Ml B.O.D. Incubators Has Been Designed Especially For Biological Oxygen Demand Determination & Other Applications Like General Incubators, Serum Studies & Enzyme Assays Test. We Can Also Customize The B.O.D. Incubators To Suit The Varied Requirement Of The Clients With In Stipulated Time Frame. Inner Chamber Made Of S.S.304 & Outer Chamber Made Of M. S. Powder Coated Full Length Inner Acrylic Door Permit Inspection Of Specimens Without Disturbing The Tem. Temp Controlled By Solid State Digital Controllers Housing All The Control With Pt-100 Sensor Illumination Light Are Provided For Viewing With Door Limit Switch. Cfc Free Hermetically Sealed Compressor Provide Temp. For Below Ambient Condition. Air Circulation Fan For Maintain Temp. Uniformity Throughout The Chamber. The Chamber Is Provided With Modular Removable Shelves Made Of S. S. For Complete Flexibility In Use. To Work On 230 Volts 50 H2. 123 Validation Protocols : Iq Oq & Pq Documentation With Calibration & Tradability Certificate Of Controller. Safety Features : Built In Temp Deviation Audio Visual Alarm, Safety Thermostat For Overshoot Temp. Cut Off System. Hrc Fuses For Compressor Heater & Mains Time Daily Circuit For Safety Of Compressor. This B.O.D. Incubator Is Available In Below Sizes: Size= 6Cu.Ft Inner Dimension W X D X H = ( 50 X 50 X 70 ) Cm Capacity= 175 Ltr No. Of Shelves= 2 124 Colony Counter: Working Temperature 5 To 50 ◦ C, 4 Digit Red Led Display, Petridish Holder, Fluorescent Lamp, Zero Reset Button, Dimension-30 ( W ) X33 ( D ) X10 ( H ) Cm, Net Weight 6.5 Kg. 125 Digital Nephelometer ( Turbidity Meter ) :Conformance:: Iso 7027 ( Ir Source ) Epa 180.1 ( Tungsten Lamp ) Measurement Range:: Auto-Ranging From 0 - 1000 Ntu Principle:: Nephelometric Non Ratio Accuracy:: + / - 2% Of Reading Plus 0.01 Ntu Resolution:: 0.01 Ntu ( 0 - 9.9 Ntu ) , 0.1 Ntu ( 10- 99 Ntu ) , 1 Ntu ( 100 - 1000Ntu ) . Response Time: < 6 Sec Display:Lcd , 3 Digit Light Source: Tungsten Filament Or Ir - Led ( 860Nm ) Power Supply: 120 - 240 Volts Ac Sample Cells: 30 M Shipping Dimensions :: 27.3X25.4X9.5Cm ( 10.7 X 10 X 3.75 ) Shipping Weight:: 1.92 Kg ( 2.9Lbs ) 126 High Volume Air Sampler: High Volume Sampler ( With Gaseous Attachment ) Technical Specifications :Flow Rate: - 0 To 1.8 M3 / Min Free Flowparticle Size: - Particles 0 To100 Microns & Below Collected On Filter Paper Holder. Spm Bigger Than 100 Microns Collected In A Separate Sampling Bottle Under The Cyclone. Sampling Time: - 24 Hours... 127 Low Volume Air Sampler: State Of The Art Microprocessor Electronics Flowrate And Volume Totalizations Displayed Are Temperature And Pressure ( 4 Options Available ) Classical Stp 0ºc, 760 Mmhg Normal T And P 20ºc, 760 Mmhg Modified Normal T And P 21.1ºc, 760 Mmhg Standard Ambient T And P 25ºc, 760 Mmhg Elapsed Time Meter Auto Zero Calibration Feature Of Flow Sensor Bright Led Display Flow Rate Accuracy Within ± 4% F.S. Rs-232 Communication Port W / Operator Selectable Download Frequency For Real-Time Data Auto Shut-Off On Time Or Volume 110 – 120 Vac, 50 / 60Hz; Single Phase 128 Hydraulic Bench: Top Tray: Size 1000 X 700 X 100 Mm ( Approx ) Water Circulation: 1 Hp Pump. Flow Measurement: Using Measuring Tank, Capacity 40L. Sump Tank: Capacity 100 Ltrs. Control Panel Comprises Of: Standard Make On / Off Switch, Mains Indicator, Etc The Whole Set-Up Is Well Designed And Arranged In A Good Quality Painted Structure 129 Crushing Value Test Apparatus: Consists Of M.S.Cylindrical Container 150 Mm ±0.5Mm Dia X 130Mm To 140Mm High With Base Plate 200 To 230 Mm. / Sqr X 6Mm Thick. A Plinger Of 148Mm ± 0.5Mm Dia X 100 To 115Mm High. Supplied Complete With Tamping Rod, 16Mm Dia X 600Mm Long, One End Rounded. And 1 No. Metal Measure 115 ± 0.5Mm Dia X 180 0.5Mm High. Consists Of Both End Open Cylinder, Base Plate, A Plunger 130 Digital Ph Meter: Measuring Range Resolution Accuracy Ph Range 0 To 14 Ph ( Min. ) 0.001 Ph ± 0.002 Ph Mv -1000.0 - 1000.0 ( Min. ) 0.1 Ph ± 0.2 Rel. Mv -1000.0 - 1000.0 ( Min. ) 0.1 Ph ± 0.2 Temperature Mtc -10.0 - 100.0 °C ( Min. ) 0.1 °C ± 0.1 °C Temperature Atc -5.0 - 100.0 °C ( Min. ) 0.1 °C ± 0.1 °C Temperature Compensation :Automatic And Manual Temperature Compensation Display : It Should Have Thin Film Transistor ( Tft ) Display Of More Than 4 Inch Color ( Blue / Red / Green / Yellow ) Display For Better Vision Of Readings With Clear And Well Arranged Icons Of Parameters Like Ph, Temperature, Mv, Date & Time Etc. Ingress Protection Level : It Should Be Ip54 Complied Protection Level. Power Requirements : It Should Be Operable With 9 -12V / 10W Dc Adapter.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 4
West Bengal View Result →
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Maharashtra View Result →
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Maharashtra View Result →
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Maharashtra View Result →
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Maharashtra View Result →
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Maharashtra View Result →
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Maharashtra View Result →
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 6
Uttarakhand View Result →
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 4
Uttarakhand View Result →
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
Uttarakhand View Result →
Contract Date: Ref. Documents Contract Value : 3.28 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 1
24.
Housing Urban and Rular Development #9481110 Technical Bid
Construction Of Main Location For T.F.C. Ram Van Gaman At District Chitrakoot (U.P.) - TFC, RAMVANGAMAN 3 Carriage of good earth by mechanical transport including loading, unloading and stacking 4 (upto 20KM) 5 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge. 6 All kinds of soil 7 Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials. 8 All kinds of soil (From 1.5 to 3 m depth) 9 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. 10 Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. 11 Supplying chemical emulsion in sealed containers including delivery as specified. 12 Chlorpyriphos/ Lindane emulsifiable concentrate of 20% 13 Diluting and injecting chemical emulsion for pre-constructional anti-termite treatment (excluding the cost of chemical emulsion) : 14 Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor : 15 With Chlorpyriphos/Lindane E.C. 20% with 1% concentration. 16 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 17 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) 18 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 19 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) 20 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. 21 Centring and shuttering including strutting,propping etc. and removal of form for 22 Foundations, footings, bases of columns etc. for mass concrete. 23 Suspended floors, roots, landings, balcnies and access platform. 24 Shelves (Cost in situ) 25 Lintels, beams, plinth bams, griders, bressumers and cantilevers. 26 Columns,Pillars, Piers, Abutments, Posts and Struts 27 Stairs, (excluding landings) except spiral-staircases 28 Edges of slabs and breaks in floors and walls Under 20 cm wide 29 Weather shade, Chajjas, corbels etc., including edges 30 Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc. including cost of de-shuttering and decentering at all levels, over a height of 3.5 m, for every additional height of 1 metre or part thereof (Plan area to be measured)Suspended floors, roofs, landing, beams and balconies (Plan area to be measured). 31 Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete upto plinth & above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. 32 Steel reinforcement for R.C.C. work including straightening, cutting, bending,placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. 33 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. 34 All works upto plinth level 35 Concrete of M30 grade with minimum cement content of 350 kg /cum 36 All works above plinth level upto floor V level 37 Concrete of M30 grade with minimum cement content of 350 kg /cum 38 Add for using extra cement in the items of design mix over and above the specified cement content therein. 39 ANCHOR BLOCK FOR STONE BENCHES 40 Boring with hydraulic piling rigs with power units, providing and installing cast in situ single under reamed piles of specified diameter and length below pile cap in M-25 cement concrete, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and the length of the pile to be embedded in pile cap etc. all complete. (Length of pile for payment shall be measured upto to the bottom of pile cap) : 41 400 mm dia piles 42 Extra over single under ream for providing additional bulbs in under reamed piles, under specified diameter(only the nos. of extra bulbs are to be paid) 43 400 mm dia piles 44 Vertical load testing of piles in accordance with IS 2911 (Part IV) including installation of loading platform by Kentledge/Anchor piles method and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of Engineer in-charge. 45 Single pile upto 50 tonne Safe capacity 46 Initial test (Test Load 2.5 times the Safe capacity) 47 Routine test (Test Load 1.5 times the Safe capacity) 48 MASONRY WORK 49 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: 50 Cement mortar 1:6 (1 cement : 6 coarse sand) 51 Providing and laying Autoclaved Aerated concrete(AAC) blocks masonry with 150mm to 300 mm thick with Grade-1 AAC blocks of density 551 to 650 kg/cum conforming to IS:2185 (Part 3) in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately). 52 Providing and laying Autoclaved Aerated concrete(AAC) blocks masonry 100mm/125mm thick with Grade-1 AAC blocks of density 551 to 650 kg/cum conforming to IS:2185 (Part 3) in super structure above plinth level up to floor V level in cement mortar 1:4 (1 cement : 4 coarse sand). The rate includes providing and placing in position 2 Nos 6 mm dia M.S. bars at every third course of masonry work. 53 WOOD WORK 54 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 55 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws 56 Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). 57 Extra for providing vision panel not exceeding 0.1 sqm in all type of flush doors (cost of glass excluded) (overall area of door shutter to be measured): 58 Rectangular or square. 59 Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality. 60 1.0 mm thick 61 Providing and fixing fly proof stainless steel grade 304 wire gauge, to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.50 mm all complete. 62 With 12 mm mild steel U beading 63 Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double acting hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge (Door handle, lock and stopper etc.to be paid separately). 64 Providing and fixing 12 mm thick frameless toughened glass partitions of approved brand and manufacturer, including providing and fixing partitions at top & bottom with aluminum channel etc. all complete as per direction of Engineer-in-charge 65 Providing and fixing approved brand and manufacturer SS 304 grade hardwares for Doorsetc. 66 Providing and fixing approved brand and manufacture SS 304 grade D type 300mm Pull Handle with 22mm dia fixed with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 67 Providing and fixing approved brand and manufacture SS 304 grade Glass door Lock, top and bottom patch fitting with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 68 Providing and fixing approved brand and manufacture SS 304 Lever Handle D-type, 22mm dia fixed with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 69 Providing and fixing approved brand and manufacture SS 304 grade SS 304 grade Mortise Dead Lock with 60mm Backset fixed fixed with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 70 Providing and fixing approved brand and manufacture SS 304 grade Tower bolt 250mm long with 10mm dia fixed with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 71 Providing and fixing approved brand and manufacture SS 304 grade Tower bolt 150mm long with 10mm dia fixed with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 72 Providing and fixing approved brand and manufacture SS 304 grade wall mounted door buffer fixed with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 73 Providing and fixing approved brand and manufacture SS 304 grade Door Stopper - door mounted hanging type fixed with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 74 Providing and fixing 85x42 mm chromium plated brass pull bolt lock with necessary chromiumplated brass screws, nuts, bolts and washers etc. complete. 75 Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete. 76 125 mm 77 Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISi, IS : 3564, embossed on the body, door weight upto 36kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete. 78 Toilet CubicalProviding and fixing Toilet Cubicle (of following standard dimension which includes 600 mm door size width) made of heat, bacteria, water, chemical, scratch, impact and anti bacterial resistant 12 mm thick solid compact laminate panelsFinish of the compact laminate should be raw silk which include doors, pilasters and intermediate panels finished with approved texture/shade as per the detail drawing and as per IS 2046 (Indian Standard) and as per fire retardant BS-476/97 standard.This also includes providing and fixing in position necessary hardware made out of Stainless Steel (Grade 316) as per manufacturers specifications and EIC instructions like (1) Door Knob, (2) Gravity Hinges, (3) Thumb turn lockset indicators, (4) Coat hooks, (5) U- Channels, (6) SS-Shoe Box Plate, (7) MS-Base Plate, (8) Rubber noise deafening tape, (9) Screws and wall Plugs. 79 Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. 80 Using M.S. angels 40x40x6 mm for diagonal braces 81 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. 82 Hot finished welded type tubes 83 Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. 84 In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works 85 Providing and fixing stainless steel (Grade 316) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). 86 Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 87 25 mm thick 88 Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. 89 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. 90 Glazed Vitrified tiles Matt/Antiskid finish of size 91 Size of Tile 600 x 600 mm 92 Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joint with white cement & matching pigments etc. complete. 93 Size of Tile 600 x 600 mm 94 Providing and fixing 1st quality ceramic glazed floor tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. 95 Providing and laying matt finished vitrified tile of size 300x300x9.8mm having with water absorption less than 0.5% and conforming to IS: 15622 of approved make in all colours and shades in for outdoor floors such as footpath, court yard, multi modals location etc., laid on 20mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as per direction of Engineer-in-Charge. 96 Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. 97 Polished Granite stone slab colour of Black, Cherry/Ruby Red or equivalent 98 Extra for pre finished nosing to treads of steps of Granite stone. 99 Extra for Granite stone flooring in treads of steps and risers using single length up to 2.00 metre . 100 Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge : 101 Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent. 102 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. 103 Granite of any colour and shade 104 Area of Slab over 0.50sqm 105 Extra for providing edge moulding to 18mm thick marblestone counters, Vanities etc. including machine polishing to edge to give high glossfinishetc.completeasper designapprovedbyEngineer-in-Charge. 106 Granite work. 107 Extra for fixing marble /granite stone over and abovecorresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive including cleaning etc. complete. 108 Extra for providing opening of required size & shape for wash basins/ kitchen sink in kitchen platform, vanity counters and similar location in marble/Granite/stone work including necessary holes for pillar taps etc. including rubbing and polishing of cut edges etc. complete. 109 12mm cement plaster of mix : 110 1:6 (1 cement: 6 coarse sand) 111 15 mm cement plaster on the rough side of single or half brick wall of mix : 112 1:6 (1 cement: 6 coarse sand) 113 18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster 1:6 (1 cement : 6 fine sand). 114 6 mm cement plaster of mix : 115 1:3 (1 cement : 3 fine sand) 116 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 117 Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour : 118 New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre 119 Painting with synthetic enamel paint of approved brand and manufacture of required color to give an shade. 120 Two or more coats on new work including priming coat of ordinary paint approved brand. 121 Finishing walls with textured exterior paint of required shade :New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm 122 Providing & fixing galvanized low carbon wire, anealed wire Chicken mesh formed by twisting two adjacent wires at least four times, forming a hexagonal shaped strong honeycomb mesh structure on joints of RCC & Brick work before plastering, of required gauge (not less than 21 gauge)and size with nails etc. complete as specified in drawing and as per the Direction of Engineer-in-charge. 123 Stone work ashlar sunk or moulded or sunk and moulded upto floor five level in cement mortar 1:6 (1 cement : 6 coarse sand) including pointing with white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade : 124 White sand stone 125 Extra for stone work ashlar sunk or moulded or sunk and moulded or carved in : 126 Triangular or Square or rectangular pillars 127 Circular or polygonal pillars 128 Extra for stone work ashlar sunk or moulded in cornices. 129 Stone work, plain in copings, cornices, string courses and plinth courses, upto 75 mm thick in Cement mortar 1:6 (1 cement : 6 coarse sand), including pointing with white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade. 130 White sand stone 131 DRY CLADDINGProviding and fixing dry cladding upto 10 metre heights with 30mm thick gang saw cut stone with machine cut edges of uniform colour and size upto 1mx1m, fixed to structural steel frame work and/ or with the help of cramps, pins etc. and sealing the joints with approved weather sealant as per Architectural drawing and direction of Engineer-in-charge. (The steel frame work, stainless steel cramps and pins etc. shall be paid for separately). 132 White sand stone - 30mm thick gang saw cut stone 133 Providing and fixing structural steel frame (for dry cladding with 30 mm thick gang saw cut with machine cut edges sand stone) on walls at all heights using M.S. square/ rectangular tube in the required pattern as per architectural drawing, including cost of cutting, bending, welding etc. The frame work shall be fixed to the wall with the help of M.S. brackets/ lugs of angle iron/ flats etc. which shall be welded to the frame and embedded in brick wall with cement concrete block 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20 mm nominal size) of size 300x230x300mm, including cost of necessary centring and shuttering and with approved expansion hold fasteners on CC/RCC surface, including drilling necessary holes. Approved cramps/ pins etc. shall be welded to the frame work to support stone cladding, the steel work will be given a priming coat of Zinc primer as approved by Engineer-in-charge and painted with two or more coats of epoxy paint (Shop drawings shall be submitted by the contractor to the Engineer-incharge for approval before execution). The frame work shall be fixed in true horizontal & vertical lines/planes. (Only structural steel frame work shall be measured for the purpose of payment, stainless steel cramps shall be paid for separately and nothing extra shall be paid). 134 Providing and fixing adjustable stainless steel cramps of approved quality, required shape and size, adjustable with stainless steel nuts, bolts and washer (total weight not less than 260 gms), for dry stone cladding fixed on frame work at suitable location, including making necessary recesses in stone slab, drilling required holes etc complete as per direction of the Engineer-incharge. 135 Applying breathable, non-reactive, antifungal, and water repellant Silane/Siloxane chemical as approved by Archaeological Survey of India/ Engineer-in-charge, of approved brand and manufacture, diluted with solvent mineral Turpentine oil in the ratio of 1:12 (One part of approved chemical :12 Part of Turpentine oil), on the existing sand stone masonry surface with two or more coats to give uniform application of chemical on the surface, all complete as per direction of Engineer-In-charge (The rate is inclusive of all materials & labours involved except scaffolding). 136 Providing and fixing stone jali 40 mm thick throughout in cement mortar 1:3 (1 cement : 3 coarse sand), including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment, matching the stone shade, jali slab without any chamfers etc. 137 White sand stone 138 Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturers specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : 139 12.5 mm thick tapered edge gypsum moisture resistant board 140 Providing and fixing false ceiling at all heights with integral densified calcium silicate reinforced with fibre and natural filler false ceiling tiles of Size 595x595mm of approved texture, design and patterns as per CPWD Specification 2019, to be laid in true horizontal level suspended on inter-locking metal T-Grid of hot dipped galvanised iron section of 0.33mmthick (galvanized @ 120 grams per sqm including both sides)comprising of main-T runners of size 24x38 mm of length 3000 mm, cross - T of size 24x32 mm of length 1200 mm and secondary intermediate cross-T of size 24x32 mm of length 600mm to form grid module of size 600 x 600 mm, suspended from ceiling using galvanised mild steel items (galvanizing @ 80 grams per sqm) i.e. 12x50 mm long dash fasteners, 6 mm dia fully threaded hanger rod upto 1000 mm length and L-shape level adjuster of size 76x25x25x1.6mm fixed with grid and Z cleat of size 25x37x25x1.6mm thick with precut hole on both 25mm flange to pierce into 12x50mm or even bigger size dash fastener if require, fixed with Glavanised iron perimeter wall angle or size 24x24x0.40 mm of length 3000 mm to be fixed on periphery wall / partition with the help of plastic rawl plugs at 450mm center to center and 40 mm long dry wall S.S screws. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in-Charge. 141 With 15 mm thick Tegular edged light weight calcium silicate false ceiling tiles 142 Providing and fixing tiled false ceiling of approved materials of size 595x595 mm in true horizontal level suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 gsm/sqm, both side inclusive) consisting of main T runner with suitably spaced joints to get required length and of size 24x38mm made from 0.30mm thick (minimum) sheet, spaced at 1200mm center to center and cross T of size 24x25mm made of 0.30mm thick (minimum) sheet, 1200mm long spaced between main T at 600mm center to center to form a grid of 1200x600 mm and secondary cross T of length 600mm and size 24x25mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600mm panel to form grids of 600x600mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, wherever, required, cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main T runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 x mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete at all heights as per specifications drawings and as directed by Engineer-in-charge. GI Metal Ceiling Lay in perforated Tegular edge global white color tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/sqm (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient ) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fiber acoustical fleece. GI Metal Ceiling Lay in perforated Tegular edge global white color tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/sqm (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient ) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fiber acoustical fleece. 143 Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. (b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. (c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineering-charge. (d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineering-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. (e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by the Engineer-in-Charge : With average thickness of 120 mm and minimum thickness at khurra as 65mm. 144 Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : (a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours.(b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. 145 Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : 146 In 75x75 mm deep chase 147 Providing and laying broken AAC Block in sunken portion of W.C. & kitchen. These broken Block mixed with cement mortar 1:8 ( 1 cement : 8 coarse sand) laid and compacted properly including supply of labour, material, and tools and plant etc. as per instruction of Engineer-in-charge. 148 Providing and fixing Heat Resistant Terrace Tiles (300 mm x 300 mm x 20 mm) with SRI (solar refractive index) > 78, solar reflection > 0.70 and initial emittance > 0.75 on waterproof and sloped surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1:4 (1 cement : 4 coarse sand) and grouting the joints with mix of white cement & marble powder in ratio of 1:1, including rubbing and polishing of the surface upto 3 cuts complete, including providing skirting upto 150 mm height along the parapet walls in the same manner. 149 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS : 1285, fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC/neoprene felt etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing and paneling to be paid for separately) : 150 For fixed portion 151 Powder coated aluminium (minimum thickness of powder coating 50 micron) 152 For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of PVC / neoprene gasket required (Fittings shall be paid for separately). 153 Powder coated aluminium (minimum thickness of powder coating 50 micron) 154 Providing and fixing 6 mm thick high performance toughened glass from approved manufacturer complete in all respects as per direction of the Engineer-in-charge. (Required properties Solar factor 0.43, U-Value (W/sq.m-K) 5.6, Visible light transmittance 0.43). The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement. 155 PLUMBING Work 156 SANITARY INSTALLATIONS 157 Providing and fixing white vitreous china extended wall mounting water closet of size 780x370x690 mm of approved shape including providing & fixing white vitreous china cistern with dual flush fitting, of flushing capacity 3 litre/ 6 litre (adjustable to 4 litre/ 8 litres), including seat cover, and cistern fittings, nuts, bolts and gasket etc complete. 158 Providing and fixing white vitreous china battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre & post flushing with water (250 ml & 500 ml consumption), having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of Engineer-in-charge. 159 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: 160 White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tap 161 Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:- 162 White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer 163 Providing and fixing Stainless Steel AISI 304 (18/8) kitchen sink of approved makeas per IS: 13983 with C.I. brackets and stainless steel plug 40 mm, including painting offittings and brackets,cuttingandmakinggoodthe walls wherever required 164 Kitchen sink with drain board 165 510x1040 mm bowl depth 250 mm 166 Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. 167 Providing and fixing Differecially abled toilets including Wash basin, Water closet,Cistern, grab bars & hand rails etc. The rate include cost of all material & labour involved in the item complete and all as per direction of engineer incharge.For physically handicap person consisting of; 168 Providing & fixing heavy quality PVC waste pipe for sink including PVC waste fitting Complete 169 Flexible Pipe 170 40mm Dia 171 Providing & fixing toilet paper holder 172 C.P. brass 173 Providing, fixing, jointing and testing in position of ISI marked UV stabilized UPVC pipesfor soil, waste SWR Type-B as per IS : 13592 suitable for rubber ring joints for vertical pipes and solvent cement joints for horizontal pipes, including all neccessary specials and fittings (confirming to IS:14735) i.e. bends, tees, junctions (with or without doors),reducers, couplers, cowels, clamps, hangers, rubber rings, clean outs, provision for C P Grating fixing for any waste connection from washing machine etc. fixing at wall / ceiling / floor level supported by clamp & hangers etc.inside duct / suspended from floor under false ceilingfor proper completion of the work. The rubber ring shall confirm to IS:5382. ( (SOIL, WASTE, RAIN WATER & VENT) 174 110 mm diameter pipe 175 Providingandfixingin position Upvc full bore P / S trap with 50 mm water seal(IS : 14735) of the following sizes .Making proper connection with solvent cement. 176 Providing, fixing & testing uPVC pipes, conforming to IS 4985 class 3 (6 kg/cm2) including injection moulded fittings, jointing with solvent cement, cutting and making good the floors and walls and jointingto trap/waste pipe, complete of outer dia. (Indirect waste) 177 40mm diameter pipe 178 50 mm diameter pipe 179 63 mm diameter pipe 180 Providing & fixing Nickel Chromium Platedliquid soap dispenser with metallic bottle of approved brand & make112 mm distance from wall of standard shape with bracket (Nickel chromium plating should pass Salt Spray Test for 200 hours) of the same materials with snap fittings of approved quality and colour, complete as per direction of Engineer in Charge. 181 Providing & fixing soap dish holder of approved design. 182 Providing and fixing CP brass single lever low flowwall mounted Sink mixer with 15 mm CP brass single lever swivel spout with waste complete with flow rate 2.5 litre per minute at 3 bar including cutting and making good the walls where required. 183 Providing and fixing of approved make following-a) Concelaed type CP Brass diverter(for hot and cold water), overhead shower with arm with rubit cleaning system with flow rate 6 litre per minute at 3 bar complete with all accessories as requiredand spoutwith flow rate 3.8 litre per minute at 3 bar, wall flange complete with all accessories as required and making good the walls wherever required. 184 Providing,Fixing wall mounted of approved make Double Coat hookon door complete. 185 Providingand fixing CP brass 2 Way Bib cock with wall flange with flow restrictor with flow rate 2.5 litre per minute at 3 bar. 186 Providing, fixing, testing & commissioning of Floor drain made of uPVC reducing elbow (110x63 mm) with horizontal drain outlet of 63 mm OD, round top of 110 mm OD. (Floor Drain) 187 Providing & fixing uPVC clean out plug with suitable opening with threaded uPVC socket fixed to uPVC pipe joints as required complete in all respects. 188 110 mm dia 189 Providing, fixing and testing of uPVC SWR inlet fittings with two or three saddle inlets of 40, 50 or 63 mm size, fabricated from 110 mm outer dia uPVC pipes and fixed to uPVC traps with solvent cement joint complete in all respect. 190 Providing and fixing SS Grating of 125 mm dia of approved quality and colour complete as per direction of engineer in charge. 191 Circular Type 192 125 mm nominal dia with 25 mm waste hole 193 Providing, Installing & fixing storage type water heater of approved make (vertical/horizontal type ) with copper container, glasswool insulation,stove enamelled M.S jacket, thermostatically controlled inner heater with pilot neon lamps, 15mm inlet stop cock valve, on inlet connection, 15mm dia C.P flexible connection pipe in inlet & outlet suitable for working pressure of 8 kg/sqcm complete as required. 194 Capacity 25 litres 195 Capacity 40 litres 196 Capacity 06 Litres 197 WATER SUPPLY 198 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. 199 Concealed work, including cutting chases and making good the walls etc. 200 15 mm nominal outer dia Pipes 201 20 mm nominal outer dia Pipes 202 25 mm nominal outer dia Pipes 203 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. 204 Internal work - Exposed on Wall 205 20 mm nominal outer dia Pipes 206 25 mm nominal outer dia Pipes 207 32 mm nominal outer dia Pipes 208 40 mm nominal outer dia Pipes 209 50 mm nominal outer dia Pipes 210 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 211 External Work 212 50 mm nominal outer dia Pipes 213 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 214 20mm nominal bore 215 25mm nominal bore 216 32mm nominal bore 217 40mm nominal bore 218 50mm nominal bore 219 65mm nominal bore 220 Providing and fixing uplasticised PVC connection pipe with brass unions : 221 45 cm length 15 mm nominal bore 222 Constructing masonry Chamber 90x90x100 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ), i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : 223 With common burnt clay F.P.S (non modular) bricks of class designation 7.5 224 Providing and filling sand of grading zone V or coarser grade, allround the G.I. pipes in external work : 225 65 mm diameter pipe 226 Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 227 15mm nominal bore 228 Providingand fixingC.P. brass angle valve for basin mixture and geyser points of approvedqualityconfirming to IS: 8931. 229 Providing and fixing enclosed type water meter (bulk type) conforming to IS : 2373 and tested by Municipal Board complete with bolts, nuts, rubber insertions etc. (The tail pieces if required will be paid separately) : 230 100 mm dia nominal bore 231 Providing, fixing, testing & commissioning of level operated water type butterfly valve conforming to IS : 13095/BS 5155 having CI iron body , ss 316 grade dick, EPDM / nitride complete with 2 Nos. matching flanges, rubber insertion, nuts, bolts and washer etc. of following sizes with locking arrangement. 232 Pressure Rating PN 25 : 233 80 mm dia. 234 Non - return valve with dual plate of CI Body SS plates vulcanized NBR seal flanged end & PN 25 rating as specified. 235 65mm dia. 236 Providing & fixing CI `Y Strainer (screwed/ flanged) with stainless steel fine wire mesh perforated sheet basket with necessary flange/ unions nuts, bolts and washers complete as required. 237 80mm nominal bore 238 Supplying and fixing in position of approved quality Solenoid Valve with by-pass arrangement, isolation cock etc. complete with all required accessories such as level sensor, level indicator, level controller and required cabling for the same. 239 50 mm dia 240 Providing, Installing and Giving satisfactory field testing of Static (Ultrasonic) Domestic Battery operated, MID (Measuring Instrument Directives) approved Static AMR Water Meters diameters having no moving/fixed part in contact with water, with fully body made up of composite material, confirming to ISO 4064 along with manufacturing test certificate and Guarantee certificate with Meter & Battery Guaranteed up-to 10 years with RF Technology for communication. Memory of the device should be directly accessible through an optical scanner. 241 50 mm dia 242 DRAINAGE 243 Providing, laying and joining in position HDPE DWC (Double Wall Corrugated)and conforming to I.S. 16098 of required grade SN-4/SN-8 and suitable for the respective working pressures with all fittings and specials, e.g. couplings, tees, bends, reducers, screwed adapters, flanged tail pieces, etc., jointing as per manufacturers recommendations, all complete including trenching, backfilling & pressure testing etc. (For Sewer & Storm water line). 244 200 mm dia (SN-4) 245 250 mm dia (SN-4) 246 250 mm dia (SN-8) 247 300 mm dia (SN-8) 248 400 mm dia (SN-8) 249 Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round HDPE pipes/ RCC pies/S.W. pipesincluding bed concrete as per standard design: 250 200 mm diameter HDPE pipe/ RCC pipe / S. W. pipe 251 Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) up to haunches of HDPE pipes/ RCC pies/S.W. pipes including bed concrete as per standard design : 252 200 mm diameter HDPE pipe/ RCC pipe / S. W. pipe 253 300 mm diameter HDPE pipe/ RCC pipe / S. W. pipe 254 Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design : 255 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 256 Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 257 300mm dia RCC pipe 258 450mm dia RCC pipe 259 Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone- III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone- III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : Inside size 90 x 80 cm and 45 cm deep including CI cover with frame (light duty) 455 x 610mm internal dimensiions total weight of cover and frame to be not less than 38 Kg. ( weight of cover 23 Kg. and weight of frame 15 Kg.), with FPS bricks with class designation 7.5With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 260 Inside size 120x90 cm and 90 cm deep including C.I. cover with frame (medium duty) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg (weight of cover 58 kg and weight of frame 58 kg) : 261 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 262 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 263 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 264 Constructing brick masonry circular type manhole 0.91 m internal dia at bottom and 0.56m dia at top in cement mortar 1:4 (1 cement :4 coarse sand), in side cement plaster 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement, foundation concrete 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size), and making necessary channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement, all complete as per standard design :0.91 m deep with S.F.R.C. cover and frame (heavy duty, HD-20 grade designation) 560 mm internal diameter conforming to I.S. 12592, total weight of cover and frame to be not less than 182 kg., fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including centering, shuttering all complete. (Excavation, foot rests and 12mm thick cement plaster at the external surface shall be paid for separately): 265 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 266 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 267 Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS : 10910 on 12mm dia steel bar conforming to IS : 1786 having minimum cross section as 23 mmx25mm and over all minimum length 263 mm and width as 165mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufactures permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design. 268 Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality 269 HD - 20 270 Circular shape 560 mm internal diameter 271 Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement and making necessary channels for the drain etc. complete : 272 For pipes 100 to 250 mm diameter 273 For pipes 350 to 450 mm diameter 274 Constructing brick masonry road gully chamber 50x45x60cm with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) including 500x450mm precast RCC horizontal grating with frame complete as per standard design. 275 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 276 EARTH WORK, CONCRETE WORK 277 Excavating trenches by mechanical / manual means of required width for pipe, cables etc including excavation for sockets ,& dressing of sides ,ramming of bottoms ,for all depth including getting out the excavated soil,& then returningthe soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming ,watering, etc and disposingof surplus excavated soil as directed, within lead of 50m. 278 All kinds of soil 279 Pipes, cables etc exceeding 80 mm dia but not exceeding 300 mm dia 280 Pipes, cables etc. exceeding 300 mm dia but not exceeding 600 mm 281 Excavating trenches of required width for pipes, cables, etc including excavation for sockets,depth upto 1.5 m, including getting out the excavated matterials, returning the soil as requred in layers not exceeding 20 cm in depth including consolidating each deposited layers by by ramming, watering,etc. and stacking serviceable material for measurements and disposal of unserviceable matterial for measurement and disposal of unserviceable matterial as directed within a lead of 50m: 282 Ordinary rock 283 Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia 284 Hard rock (requiring blasting) 285 Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia 286 Earth Work in excavation by mechanical means (Hydraulic / excavator ) manual means over area (exceeding 30 cm in depth ,1.5m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50m and lift upto 1.5m, as directed as engineer incharge. 287 Ordinary Rock 288 Hard Rock(requiring blasting) 289 TUBE WELL BORING WITH PUMP 290 Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge, upto 90 metre depth below ground level. 291 400 mm dia 292 Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, beyond 90 metre & upto 150 metre depth below ground level. 293 400 mm dia 294 Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge.ection of Engineer -in-charge. 295 200 mm nominal size dia 296 Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 297 200 mm nominal size dia 298 Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge. 299 Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by V notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge. 300 Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: 301 200 mm dia 302 Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete. 200 mm clamp. 303 Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I). 200 mm dia. 304 Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. 65 mm dia nominal bore 305 Sypply and Installation of 800 LPM Submersible Pump Set of 10 H.P. capacity, K.S.B. Make including Starter panel, support wire, A. Meter etc. complete. 306 Supply and fixing of nylon jali around the slotted pipes complete as required. up to 10 meter 307 Sypply and laying of alluminium conductor pvc insulated armoured served sheathed cables 1100 volts grade at a depth of 750 mm below ground level over a cushion of 75 mm thick sand all around and protected with burnt brick on sides and on top. On surface the cable run shall be fixed on m.s clamps etc. of suitable size or as directed by the Engineer in charge , complete in all respect . the armouring of the cable shall be properly connected with the earth conductor by clamps etc. 308 35 SQ.MM 3-1/2 core 309 Water testing chemical and bactriological 310 RAIN WATER HARVESTING 311 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil. 312 Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials. All kinds of soil 313 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) 314 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) 315 Centering and shuttering including strutting, propping etc. and removal of form for : Suspended floors, roofs, landings, balconies and access platform 316 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation-7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand) 317 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level & above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. 318 15 mm cement plaster of mix : 1:4 (1 cement: 4 coarse sand) in single coat on rough side of single or half brick wall. 319 Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) as per standard design : With 20x20 mm square bar 320 Supplying and fixing C.I. cover without frame for manholes : 500 mm diameter C.I. cover (medium duty) the weight of the cover to be not less than 58 kg 321 Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, upto 90 metre depth below ground level. 322 All types of soil 323 400 mm dia 324 Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge. 325 200 mm nominal size dia 326 Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, onforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 327 200 mm nominal size dia 328 Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. 329 Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-incharge. 330 Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge. 331 Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineerin- charge. 332 Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by “V” notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in pproved laboratory, i/c disinfection of ubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per uirement and direction of Engineer-in-charge. 333 Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: 200 mm dia 334 Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I). 200 mm dia 335 Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m: 336 All kinds of soil 337 Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia. 338 Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 339 150 mm dia. R.C.C. pipe 340 Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round P.V.C. pipes including bed concrete as per standard design: 341 150 mm diameter P.V.C. pipe 342 Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 coarse sand (Zone III) : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design:Inside dimensions 600x 850 mm and 45 cm deep for pipe line with three or more inlets :With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 343 Constructing brick masonry road gully chamber 50x45x60 cm with bricks of class designation 75 in cement mortar 1:4 (1 cement : 4 coarse sand) including 500x450 mm pre-cast R.C.C. horizontal grating with frame complete as per standard design : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 344 FIRE FIGHTING WORKS 345 Supply, installing, testing and commissioning of clear water packagedFire Fighting Pumping System - to be placed near water tank on Terrace ( fixed speed type) as per following details: 346 Supplying,Installation,testing & commissioning of dust & vermin proofdouble door with canopy type taperd roof wall / floor mounted compartmentlised feeder piller type cubical control Panel for fire fighting terrace pump of front area not less than 1.0 Sqmtr. and depth not less than 300 mm, made out of 2mm thick CRCAsheet with 100 Amp. 4 strip aluminium bus bars with front openable door & locking arrangement, interconnection, control wiring, intrigation with pressure switch i/c suppying & fixing following switchgears & control gears/starters etc. as required.Incomming63 Amps. TP & N SFC with HRC fuses Voltmeter (0-500 Volt) with selector switch.Ammeter (0-60 Amps.) with selector switch & CTs.Set of 3 phase indication lampSuitable HP fully automatic Star/Delta Starter with over load protection, current sensing type single phase preventor complete with all accessories and internal wiring required for automatic operation.Selector switch for local/remote, auto/manual/off operation ON/OFF indication etc. 347 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required. It should be complete as per specifications & directions of Engineer-in-charge. 348 3 X 10 sq. mm (22mm) 349 Supplying & laying one number XLPE insulated PVC sheathed Aluminium Conductor armoured UG cable of1.1 KV grade Conforming to IS 7098/1988 with upto date ammendment of following size in the existing RCC/HUME/ METAL /GI /CI /Stoneware/DWC pipe/masonary Open Duct/ cable tray/ open in air etc. as requred. 350 3 core,10 sq.mm. Aluminium Armoured 351 Providing laying, testing & commissioning of C class heavy duty MS Pipe conforming to IS 1239/3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground including welding, excavation & providing cement concrete blocks as supports, anticorrosive treatment with coaltar/asphalt tape as per IS 10221, refilling the trench etc. of following sizes complete as required. ( For Underground ) 352 100 mm. Dia 353 Providing, laying, testing & commissioning of C class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required.(Plant Room piping/Vertical Riser/Downcomer/Floor) 354 25 mm dia 355 32 mm dia 356 40 mm dia 357 50 mm dia 358 65 mm dia 359 80 mm dia 360 100 mm dia 361 Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required : 362 Single headed Gunmetal 363 Supplying and fixing Single headed external yard hydrant valve with 1 No. 63 mm dia instantaneous FM Gunmetal/Stainless Steel coupling and cast iron wheel, ISI marked, conforming to IS 5290 (type A) with blank Gunmetal/Stainless Steel cap and chain as required : 364 Single headed Gunmetal 365 Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : 366 100 mm dia 367 Supplying and fixing orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required. 368 Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required : 369 100 mm dia 370 Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange. 371 100 mm dia 372 Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required : 373 Gun Metal 374 Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required.20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 1258520 mm nominal internal dia gun metal globe valve & nozzle.Drum and brackets for fixing the equipmets on wall. Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket.36 m 375 Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required : 376 Gun metal 377 Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required : 378 2 way-100 mm dia M.S. Pipe. 379 Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and paintingwith synthetic enamel paint of approved shade as required. 380 Providing, fixing, testing & commissioning of 15mm dia quartzoid bulb type sprinklers of rating 68 degree centigrade with required accessories : 381 Upright Sprinkler 382 Providing & fixing flow switch in following sizes M.S. pipe including connection etc as required. 383 100mm dia 384 Providing, fixing, testing & commissioning of installation control valve of cast iron body, brass/bronze working parts comprising of water motor alarm, bronze seat clapper, clapper arm and hydraulically driven mechanical gong bell to sound continuous alarm when the wet riser/sprinkler system activates, pressure gauges, emergency releases, strainer, pressure switch, cock valve complete with drain valve and bypass, test control box, ball valves, MS pipe of required size, flanges, orifice plate, gasket etc of follwing sizes as required 385 100mm dia 386 Supply, fixing, testing and commissioning of screwed type brass/bronze lever operated ball valve of full flow with stainless steel ball (AISI 304 & spindle AISI 410) with setting & gland of superior quality having minimum working pressure of 16 kg/sqcm. 387 25 mm Dia 388 Providing and fixing 25 mm dia inspection & testing assembly with gun metal ball valve, gun metal sight glass ,Reducer ,union, G.I PIPE. connection to drain pipe/riser. 389 Providing and fixing in position the industrial type pressure gauges with gun metal / brass valves complete as required 390 Providing and fixing standard firemans axe with heavy insulated rubber handle conforming to IS: 926 complete. 391 Providing & Fixing of MS door made up of 16 gauge MS Sheet capable of accommodating fire hose reel, landing valve, hose pipes, fittings, 1 No. CO2& 1 No. Dry podwer type portable fire extinguishers & accessories. The door shall have a front glass with lock and key arrangement & shall be painted with one coat of primer & two coat of finished stove enamelled post office red colour paint & FIRE HOSE written on front. (Approx. size of door: 2100 mm HEIGHT, WIDTH OF DOOR AS PER SHAFT SIZE ) 392 Providing and fixing hose cabinet of size 750mmX600X250mm made of 16 gause thick MS sheet with 4 mm thick float glass doors in front painted FIRE in red paint i/c recessary locking arrangement suitable to accommodate external hydrant with butterfly valve 2 nos. 15 mtr. long hose pipe. 1 no. brach pipe mounted on wall or raised brick platform & duly painted with post office red externally and white internally with synthetic enamel paint complete in all respects for external hydrant. as directed by Engineer-in-Charge. 393 Providing, Fixing, testing and commissioning of resilient rubber lined single arch vibration eliminators suitable for raw water up to 45 deg. C temperature, working pressure 11 Kg/cm2 and test pressure 16 Kg/cm2 to provide relief from stresses at pipe flanges. 394 80 mm dia 395 Supply and fixing of 4 Nos G.I round bottom FIREBUCKETof 9 LTR. Capacity field with stand including proper supporting /mounting arrangement MS Angle Iron Frame painted by fire red colour over 2 coats of red oxide paint and written with white paint FIREcomplete in all respects as per direction of Engineer Incharge . 396 Providing, storing, handling, shifting, installation, testing and commissioning of halon free portable fire Extinguishers as described below: 397 Concealed work, including cutting chases and making good the walls etc. 398 Providing and fixing of 4.5 Kg. carbon-di-oxide type fire extinguishers consisting of welded M.S. cylinderical body, squeeze lever discharge valve fitted with pressure indicating guase ingernal discharge tube 30 cms long high pressure discharge hose, discharge nozzle, suspension bracket conforming ro IS:15683 finished externally with re enamel paint and fixed to wall with brackets complete with internal charge. 399 Providing and fixing 6.0 Kg. ABC Powder type fire extinguishers consisting of welded M.S. cylinderical body, squeeze lever discharge valve fitted with pressure indicating guase internal discharge tube 30 cms long high pressure discharge hose, discharge nozzle, suspension bracket conforming to IS:15683 finished externally with re enamel paint and fixed to wall with brackets complete with inernal charge. 400 Providing, fixing, testing and commissioning of 50 Litres (trolley mounted) Mechanical Foam type Fire Extinguisher. In HP Mild Steel Cylinders ISI marked TAC approved fitted with pressure indicating gauge, internal tube, squeeze lever type valve fully charged complete in all respects including wall suspension bracket / trolley mounted and confoming to IS:13386 . 401 Providing, fixing, testing and commissioning of CO2 type Fire Extinguisher of capacity 22.5 kg filled with Co2 Gas as per IS 15222 with controll discharge mechanism fitted with Hose, Horn & TROLLEYconfirms to IS 2878 bearing ISI mark. Co2 Cylinder as per IS 7285. 402 Providing and fixing 2 kg capacity clean agent-HFC 236FA Stored Pressure type fire extinguisher ISI marked under IS:15683 complete with importedNovec 1230 manufactured by 3M, with Zero Ozone Depeltion Potential and Very Low Global Warming Potential of 1 with 20 Years Blue Sky Warantee against any regulatory Bans and Restrictions. 403 ELECTRICAL WORK 404 WIRING 405 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. 406 Group C 407 Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. 408 Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steelconduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. 409 Group C 410 Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required. 411 1 or 2 Module (75mm×75mm) 412 3 Module (100mm×75mm) 413 4 Module (125mm×75mm) 414 6 Module (200mm×75mm) 415 8 Module (125mm×125mm) 416 12 Module (200mm×150mm) 417 Supplying and fixing following modular switch / socket on existing modular plate and switch box including connections but excluding modular plate etc as required. 418 5/6 amps switch 419 2 way 5/6 amps switch 420 15/16 amp switch 421 3 pin 5/6 amp socket outlet 422 6 pin 15/16 amp socket outlet 423 Telephone socket outlet 424 TV antenna socket outlet 425 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. 426 2 x 1.5 sq.mm. + 1 x 1.5 sq.mm. earth wire. 427 2 x 2.5 sq.mm. + 1 x 2.5 sq.mm. earth wire. 428 2 x 4 sq.mm. + 1 x 4 sq.mm. earth wire 429 Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required. 430 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 431 Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. 432 Installation of exhaust fan in the existing opening , including making good the damage, connection, testingcommissioning etc. as required. 433 (a): Up to 450mm sweep 434 Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. 435 Extra for fixing the louvers / shutters complete with frame for a exhaust fan of all sizes. 436 Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, “C” curve including connections, painting etc. as required. 437 Installation, testing and commissioning of ceiling fan,including wiring the down rods of standard length (upto 30 cm) with 1.5sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required. 438 Providing and fixing M.S. Fan clamp type I or II of 16 mm dia M.S. bar, bent to shape with hooked ends in R.C.C. slabs or beams during laying, including painting the exposed portion of loop, all as per standard design complete as required. 439 Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing. 440 Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. 441 20 mm 442 25 mm 443 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 444 20 mm 445 25 mm 446 Supplying and fixing 25 mm dia MS flexible pipe with PVC coating along with all ancillaries and accessories like coupler etc. as required. 447 Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required 448 Supplying and fixing Data Socket Outlet including modular base and cover plate and 1.6mm thick GI Box etc, complete as required with all acessories and upto the satisfaction of engineer-in-charge. 449 Supply, Installation, Testing & Commissioning of LSZH Cat 6 unshielded twisted pair computer cable with 23 AWG solid copper conductors in existing concealed / surface conduits / Raceways, complete as required and as per technical specifications. (for DATA & Voice outlets) (From ONT box / Rack to Outlets). 450 DISTRIBUTION BOARD 451 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/ RCCB / Isolator). 452 8 way , Double door 453 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as r.equired. (But without MCB/RCCB/Isolator). 454 6 way (4 + 18), Double door 455 8 way (4 + 24), Double door 456 Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally usedwhere 3 phase outlets are required.) 457 12 way (4 + 36), Double door 458 Supplying and fixing Cable End Box (Loose Wire Box) suitable for following single pole and neutral, sheet steel, MCB distribution board, 240 Volts, on surface/ recess, complete with testing and commissioning etc. as required. 459 For 8 way, Double door SPN MCBDB 460 Supplying and fixing Cable End Box (Loose wire box) suitable for triple pole and neutral, sheet steel, Vertical MCB distribution board, 415 V, on surface/ recess, complete with testing and commissioning etc. as required. 461 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 462 Single pole 463 Supplyingand fixingsingle pole, blanking plate in the existing MCB DB complete etc. as required 464 Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 465 25 A 466 40 A 467 63 A 468 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 469 12 way (4 + 36), Double door 470 Supplying and fixing Cable End Box (Loose Wire Box) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 Volts, on surface/ recess, complete with testing and 471 For 8 way, Double door FP MCBDB 472 Supplying and fixing of following MCBs, 415 volts, C curve, miniature circuit breaker suitable for inductive load offollowing poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 473 25A 4P MCB 474 40A 4P MCB 475 63A 4P MCB 476 EARTHING 477 Earthing System 478 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 Meter long etc. with charcoal/ coke and salt as required. 479 Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 Meter long etc. with charcoal/ coke and salt as required. 480 Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. 481 Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. 482 Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. 483 LT CABLES & TERMINATIONS 484 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. 485 Above 35 sq. mm and upto 95 sq. mm 486 Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size on cable tray as required. 487 Upto 35 sq. mm (clamped with 1mm thick saddle) 488 Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp) 489 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required. 490 4 X 25 sq. mm (28 mm) 491 3½×70 sq.mm (38mm) 492 Supplying, unloading, storing of following sizes of 1.1 kV grade XLPE insulated, FRLS outer sheath (Heavy duty) Aluminium/copper conductor, armoured/unarmored cables as per mentioned code, suitable for working voltage upto and including 1100 Volts,to be laid and tied on existing overhead cable trays; or buried underground or laid and tiedover MS supports in masonry trenches alongwith the test report of following sizes of cable to be submitted by the contractor at the time of delivery of material at site. 493 3.5C X 70 Sqmm Al. Armd. 494 4C X 25 Sqmm Al. Armd. 495 4C X 6 Sqmm Cu. Armd. 496 3C X 6 Sqmm Cu. Armd. 497 1C X 6 Sqmm Flexible wire including termination 498 Supplying following 1.1kV grade, XLPE insulated, FRLS type control cables,suitable for 415V, 50Hz, AC system, with inner and outer PVC sheath, outer sheath provided with FRLS insulation and with all components as mentioned in BOQ, specifications and schedule, complete as required. 499 4C X 2.5 sqmm copper conductor 500 6C X 2.5 sqmm copper conductor 501 Supplying and making end termination with brass compression gland and copper lugs for following size of PVC insulated and PVC sheathed / XLPE copper conductor cable of 1.1 kV grade as required. 502 4C X 6 Sqmm Cu. Armd. 503 3C X 6 Sqmm Cu. Armd. 504 CABLES MANAGEMENT 505 Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 506 100 mm width x 50 mm depth x 1.6 mm thickness 507 150 mm width x 50 mm depth x 1.6 mm thickness 508 Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray bends (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 509 100 mm width X 50 mm depth X 1.6 mm thickness 510 150 mm width X 50 mm depth X 1.6 mm thickness 511 Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray Tee (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 512 100 mm width X 50 mm depth X 1.6 mm thickness 513 150 mm width X 50 mm depth X 1.6 mm thickness 514 LIGHTING FIXTURES & FANS 515 The CRI of the fixtures used in should be minimum 90. LED binning < 3-Step MacAdam UGR<19All fixtures shall be with prismatic diffuser. All light fixtures shall be LED having LM79 and LM80 certification from NABL accreditedlaboratory and relevant approved IES files for Dialux. Before dispatch of approved light fixtures,third party test shall be carried out by NABL accredited lab and the test reports shall be submitted.The Service Life of the fixture including driver/control gear should be minimum 50,000 burning hours. The THD should be less than 10%.The housing of the indoor fixtures should be extruded aluminium/CRCA.The IP category should be IP20 or higher for indoor applications and IP65 or higher for outdoorapplications. The Surge Protection to be provided conforming to relevant IS standards/IEC 61643-II Class-2 &EN 61643-II Type-2. The manufacturer’s name/logo should be engraved/embossed on the housing/body or Name/Logo onaluminium plate labels or Name/logo printed on housing/body. The warranty period on complete luminaire including driver/control gear, LED, all accessories should be 5 years from the actual date of completion of work. The Power factor should be 0.95 or higher.All light fixtures (internal/external) and drivers shall be BIS certified. The manufacturer shall submitBIS certificates with respective R codes for each fitting and driver for approval before execution. Number of fittings shall be provided on the basis of average illumination range for different areasmentioned below subject to maximum LPD specified in CPWD internal specification 2013 & ECBC 2017 (ECBC+ Building). All the light fixtures used for indoor applications should be available with DALI Dimmable driver option (for Apartments & Club Areas) 516 2ft x 2ft LED Panel - Surface Mounted.- Wattage : 30W -36W - Minimum System Efficacy-120 lm/W. 517 Downlight - Surface Mounted.- Wattage : 10W -15W - Minimum System Efficacy-120 lm/W. 518 Wall Bracket light- Wall Mounted.- Wattage : 10W -15W - Minimum System Efficacy-120 lm/W. 519 4ft LED Batten Tube Light -Surface Mounted.- Wattage : 36W -40W - Minimum System Efficacy-120 lm/W. 520 4ft LED Batten Tube Light -Wall Mounted (IP-65)- Wattage : 36W -40W - Minimum System Efficacy-120 lm/W. 521 Mirror Light.- Wattage : 5W -10W 522 Bulkhead Wall mounted - Lumen Package 700 lm- Minimum System Efficacy - 100 lm/W 523 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 140-285V, 50 Hz, single phase AC Supply, earthing etc. complete as required. 524 Supply, Installation ,Testingand Commissioning of Exhaust fansforexhaust air as shown on drawings. Eachfan shall be complete with permanent split capacitor, mountingplate andaccessorieslike wire guard, birdscreen andgravitylouvers forweatherprotection as required. Fan selection, arrangement andelectrical characteristics shall be as follows: 525 450 mm dia 900/1400 RPM fan suitable for 220+6%Volts, 50 Hz, single phase AC supply. 526 Main L.T. Panel :Supply& Erracetion of factory fabricated & wired metal clad dust and vermin proof floor mounting, M.S. Channel Base with bottom and top cable entrise Electrical control panel with TPN ACB (65 KA,4Pole Elect draw out , Micor processer Release IPR2) and TPN MCCBs (Four Pole 36 KA with thermal magnatic release) Switches and instrument chamber etc.complete in all respects. The instrument chamber shall be separate and shall comprise of flush type/digital ammeter Voltmeter,Selector switches for ammeter and Voltmeter, instrument fuses, current transormer etc. The Board shall have suitable capacity electrolytic aluminium busbars as per IS8623 insulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/ DMC support with detEachable side covers and shall be suitable for extension on the sides. The switches entry boxes shall be complete with suitable cable end boxes reverse. The Job includes the grounting of the board as per directions of Engineer-in charge. All out goings of 100 Amp and above Will be provided with Amp Metre, current transfomers and selector switches etc and insurtrment fuse. The switch board shall be fabicated with CRCA sheet with a minimum thickness of 1.6 mm/2mm.Cubicle type switch board shall be of cat A & B Only. CAT. B Cubicle TypeIncoming - 527 1600 Amp /415 Volt ACB -1 No.Bus-Bar -1600 Amp /415 Volt ACB -1 No.Outgoing -200 Amp MCCB - 1 Nos.( to Audi block light panel )400 Amp MCCB - 1 Nos.( to Audi block AC panel )630 Amp MCCB - 1 Nos.( to fedder pillar panel )250 Amp MCCB - 1 Nos.( to fire pump room panel )40 Amp FP MCCB - 4 Nos.(Street light feeder pillar panel)200 Amp FP MCCB - 2 Nos.(Spare) 528 Bus-Bar -1600 Amp /415 Volt ACB -1 No.Outgoing -200 Amp MCCB - 1 Nos.( to Audi block light panel )400 Amp MCCB - 1 Nos.( to Audi block AC panel )630 Amp MCCB - 1 Nos.( to fedder pillar panel )250 Amp MCCB - 1 Nos.( to fire pump room panel )40 Amp FP MCCB - 4 Nos.(Street light feeder pillar panel)200 Amp FP MCCB - 2 Nos.(Spare)FEEDER PILLAR PANEL: 529 Incoming -630 Amp MCCB - 1 No.Outgoing - 200 Amp 4P MCCB - 3 Nos. 100 Amp 4P MCCB - 2 No.100 Amp 4P MCCB - 1 No. 40 Amp 4P MCCB - 1 No. (for Spare)(Complete as per requirment directed by Project Manager.) 530 Design, manufacture, testing at works, supply, including supervision during installation testing & commissioning of following floor / wall mounted clad switchboard, factory built, modular, sectionalised, dead front, fully compartmentalized with hinged lockable detachable front & back openable, Form IIIB type extensible Partial Type Tested Assembly, IEC-60439 compliant LT cubicle panel of suitable size, suitable for operation on 415 volts, 50 Hz AC 3 phase 4 wire supply system fabricated from powder coated CRCA sheet steel, with all load bearing members of minimum 2mm thickness , all non-load bearing members of minimum 1.6mm thickness and minimum 3mm thick gland plates. The panels shall be fabricated in easily transportable sections, length, height, depth etc. to match with site condition, having vibration free structure with stiffeners provided as required. EXTERNAL LIGHTING PANEL 531 Supplying, installation, testing and commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the following loop modules and capable of supporting not less than 240 devices (including detectors) and minimum 120 detectors per loop and loop length up to 2 km, network communication card, minimum 320 character graphics/ LCD display with touch screen or other keypad and minimum 4000 events history log in the non volatile memory (EPROM), power supply unit (230 ± 5% V, 50 hz), 48 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger. The panel shall have facility to connect printer to printout log and facility to have seamless integration with analog/digital voice evacuation system (which is part of the schedule of work under SH: PA System) and shall be complete with all accessories . The panel shall be compatible for IBMS system with open protocol BACnet/ Modbus over IP complete as per specifications. Two Loop Panel. 532 Supplying, installation, testing & commissioningof intelligent analog addressablephotothermaldetectorcompletewithmountingbase complete as required. 533 Supplying, installation, testing & commissioning of response indicator on surface/recessed MS Box having two LED, metallic cover complete with all connections etc as required. 534 Supplying, installation, testing & commisssioning of intelligent addressable programmable sounder complete as required. 535 Supplying, installation, testing & commissioning of fault isolator complete with base as required. 536 Supplying, installation, testing & commissioning of intelligent addressable thermal detector with rate of rise cum fixed tempreature thermistor complete with base as required. 537 Supplying, installation, testing & commissioning of addressable fire control module complete as required. 538 Supplying, installation, testing & commissioning of addressable manual call point complete as required. 539 Supplying, installation, testing & commissioning of addressable horn cum strobe complete as required. 540 Supplying, installation, testing & commissioning of intelligent interface unit BACnet/ Modbus protocol i.e. supplying communication links between building management system and fire alarm control panel complete as required. 541 Supplying and fixing 25 mm dia MS flexible pipe with PVC coating along with all ancillaries and accessories like coupler etc. as required. 542 Supplying & laying of 2x1.5 sqmm fire survival armouredcable, 600/1000V rated with annealed copper conductorhaving glass mica fire barrier tape covered by an extrudedlayer of Cross Linkable Ethylene Propylene Rubber (EPR)insulation and LSZH inner bedding, steel wire armouring & LSZH outer sheath complete as required. 543 Supplying & Fixing in position GI Box for installation of detectors on true Ceiling complete as required to do the job in all respect in accordance with laid specification or upto the satisfaction of engineer in charge. 544 Supply, installation,testing and commissioning of EXIT light, self contained 6W luminaire complete with flush mounting frame ,sign label,fluorescent tube and battery and with label EXIT/RIGHT/LEFT/UP/DOWN as required.. 545 Supplying, installation, testing & commissioning of 6 zone, voice alarm controller with USB, MP3 player (including 6 zone button paging station) with seamless integration facility with main fire alarm panel for voice evacuation complete as required. 546 Supplying, installation, testing & commissioning of 1.5/3/6W ceiling speaker complete as required. 547 Supplying, installation, testing & commissioning of digital audio amplifier 150 Watt, 25V rms operating at 240 Volt AC Supply complete as required. 548 SITC of 1X500W/480W Class-D Amplifier with 2 independent channels and can provide automatic re-settable overcurrent, overload, overheating, overvoltage, under-voltage and DC protection 549 Supplying, installation, testing & commissioning of Voice command keypad 6 zone, with microphone assembly complete as required. 550 Supplying and drawing of cable Fire Retardant PVC insulated copper conductor cable in the existing surface / recessed steel conduit of following pairs, cores and size including connections and interconnections etc. as required. 551 speaker cable Two pair, 2-core, 1.5 sqmm 552 Supplying and fixing 25 mm dia MS flexible pipe with PVC coating along with all ancillaries and accessories like coupler etc. as required. 553 UPS & INVERTERS 554 Supply, installation, testing and commissioning of 10 kVA UPS, 3 phase (415 V + 15%) Volts input & 3 phase output (440 V + 1%), 50 Hz, 100% IGBT inverter & converter, Input harmonic Current THD 3% typical at 100% load, 6% maximum at 50% load and 30 min battery backup for UPS along with battery cabinet complete in all respect including supporting steel structure for UPS and Battery as required. Quotedprice shall be inclusiveof approved rating single core copper conductor cable connecting UPS and batteries. 555 EXTERNAL LIGHTING 556 Pole Light -Pole mounted - Lumen Package -4000/6500/7200/9200 lm- Minimum System Efficacy - 120 lm/W 557 Bollard - Surface mounted - Lumen Package - 300/400 lm - Minimum System Efficacy - 35 lm/W 558 Supply, Installation, Testing & Commissioning of Recessed Inground Up Light fixture 10 Watt LED , integral driver, protection IP 66, CLASS I as complete as required. (Tree Up Lighting) 559 Supply, installation, testing & commissioning of LED Post Top Luminaire consuming a system wattage of 36 - 42W & the luminaire shall be with system efficacy >75lm/W. Housing: Die Cast Aluminium , IP66 ,The operating CCT shall be 5700K with CRI of ≥70. The luminaire shall be with BIS Registered electronic driver with input voltage range of 150 to 270V , THD ≤ 10% & PF ≥ 0.9, 50,000 Hrs LED Life with L70 Criteria.The LED Driver shall be easily avaiable in India for repair and service. The LED shall be SMD type. Luminaire shall have minimum surge protection of 4KV.The luminaire shall be with following certifications: LM79& LM80 issued by LED manufacture along with Photo Biological Safety Standard. CAT REF: LT Primus PT 40Wor approved Equivalent. 560 Height = 5 MetresTop dia = 70mmminBottom Dia = 130mm minThickness =3mmSingle arm pole suitable for mounting of with base plate of size 200 mm x 200 mm x 12 mm thick, suitable for mounting of light fixture 561 Height = 6 MetresTop dia = 70mmminBottom Dia = 155mm minThickness =3mmSingle arm pole suitable for mounting of with base plate of size 260 mm x 260 mm x 16 mm thick, suitable for mounting of light fixture 562 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc..direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 563 63 mm dia (OD-63 mm & ID-51 mm nominal) 564 120 mm dia (OD-120 mm & ID-103 mm nominal) 565 EXTERNAL LIGHTING PANELIncoming :One (1) No 100 Amp. 4P MCCB of 25KABreaking capacity Metering :One (1) No. (0-500V) 96 x 96 Sqmm voltmeter with control fuse & selector switch.One (1) No. (0-100A) 96 x 96 Sqmm CT operated Ammeter with selector switch, CTs etc.One (1) No. of Phase Indication Lamp each incomingBus Bar :One (1) No. 120 Amp.TPN aluminimum bus bar of suitable length.Outgoing :10 No.16 Amp DPMCB. (10 KA)SPARE & SPACE - 2 NoPanel described as above 566 SUBHEAD IV-MISCELLANEOUS 567 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc.conforming to IS 14930, Part II complete with fitting and cutting,jointing etc. in the existing trench, complete as required. 200mm Dia200mm dia 568 SUBHEAD V-EXTERNAL LIGHT 569 Conical Arch Street Lighting Pole of 6000mm Height suitable for mounting street light luminaires, made out of hot rolled steel grade E250, as per IS 2062:2011 and designed suitably for wind speedupto 50m/s wind conforming to IS 875: PART -3:1987. The perfect conical profile extends from the square base plate of MS (grade E250) of size 300mmx300mm, 16mm thick and facilitated with 4 elongated slots 48mm x 24mm at CC 215mm to suit the 500mm, J-type, M20 bolts (Grade 4.6). The cable entry hole Ø70mm is provided at the centre of the baseplate. The continuously tapered pole shall have top Ø 70 mm and bottom Ø 155 mm, 3mm thick suitable to mount an artistically designed and angularly curved arm bracket that suits the conical form factor of the pole. The pole should be Arched on the top to mount the luminaire with the help of bracket. A base compartment for weather proof control box is provided at a height 300mm above the base plate with a die cast door contoured to the poless shape housing the gear tray, prewired with 2.5 Sq.mm cable, Siemens/Anchor make MCB, terminal connectors for loop in loop out arrangement. The make of poles should be as per Ligman/RR Ispat/Klite. The surface preparation of the pole & components shall be done by shot blasting which is environmentally safe eliminating the chemical and acid use and ensuring the thorough removal of impurities like, rust, oxides and other unwanted particles from the surface for high standard coating. The surface finish of the pole shall be Zinch rich primer coat & pure polyester powder coating providing 60 Microns DFT. with KL 4392 Avenue 100, Dimension 526x174 x 90 mm wattage upto 100w LED 570 Supply, Installation, Testing and Commissioning of LED RGB / RGBW flood lighting luminaire for facade lighting with Die-cast aluminium housing, powder-coated finish, of following wattage. Luminaire shall be capable of producing dynamic color changing light for with 16 million colors by DMX / Ethernet based control. The beam angle of the fitting shall be narrow, medium, wide or asymmetric as per the requirement. Luminaire shall be complete with driver and capable of operating at line voltage without any separate power supply from 100-270VAC, 50Hz with powerfactor > 0.9. Fixture shall be suitable to operate at an ambient temperature range of -10°C to + 50°Cand shall be IP65 and IK06 rated. Life time shall be at least L70:50000 burning hours at 50°C. Luminaire shall be conforming to BIS (IS10322 and shall be complete with all necessary accessories required for proper working of fixture including weather proof connection cables, water proof connectors etc. as required. 30 W 571 Supply, Installation, Testing and Commissioning of LED RGB / RGBW Linear Wall Washer luminaire for Facade lighting with aluminium extruded housing, of following wattage. Luminaire shall be capable of producing dynamic color changing light with 16 million colors by DMX / Ethernet based control. The beam angle of the fitting shall be narrow, medium, wide or asymmetric as per the requirement. Luminaire shall be complete with driver and capable of operating at line voltage without any separate power supply from 100 to 270 VAC, 50 Hz, power factor > 0.9. Fixture shall be suitable to operate at ambient temperature range of-10°Cto+50°Cand shall be IP65 and IK06 rated. Life time should be at least L70 : 50000 burning hours at 50 C. Luminaire shall be conforming to BIS and shall be complete with all necessary accessories required for proper working of fixture including weather proof connection cables, water proof connectors etc. as required. 25 W 572 SITC OF DG SETS 573 Design, manufacturing, testing at works, supply of 3 Phase, 415V, 50 Hz and 1500 RPM Diesel Generator Set of following ratings. Engine shall be complete with turbo charger, base frame, lube oil system, Heat Exhanger (HE cooled), Control Panels, Electric Starter 24V DC, required batteries, battery charging alaternator, electronic governor, instrumentation, day service diesel fuel tank, exhaust silencers including insulation, engine mounted control panel with monitoring and alarm features, utility piping, anti-vibration pads, Alternator direct coupled to Engine along with static excitation system and AVR Panel, and all required accessories complete as required and as per the specifications. The scope of work shall not include AMF Panel, cabling and earthing. DG shall be procured to the standards as in MoEFCC notification No.Q-1s017losl 2OL2-CPW and GSR 804(E) dated 03.1 1 .2022 The DG Set shall be provided with genset controller for AMF,Auto-load sharing, and shall have electrical and mechanical parameter monitoring. The controller shall include following electrical protections - under & over frequency and voltage, overload (KW), overcurrent, short circuit, reverse power, excitation failure etc. 62.5 KVA(with Acoustic Enclosure) 574 Supply of 4mm thick MS diesel day oil tank duly painted with two coats of primer after pre-treatment, and one coat of synthetic enamel paint with manhole, inlet and outlet connections with gate valves, drain plug, piping between tank and engine incase of inbuilt day oil tank, vent, mechanical oil level indicator, low level/ high level alarms, including support arrangement etc. mounted on suitably painted MS staging to maintain gravity flow of diesel oil from tank to DG Set. 575 120 Litres Capacity for 62.5kVA DG set 576 Fuel Pipe Line & Misc. Items Works 577 Supply, installation, testing & commissioning of 40mm dia MS C Class fuel supply and return piping from diesel day oil tank to the DG Set, including all necessary fittings like tees, bends, ball valves etc. complete in all respects as per the specifications. 578 Supply, installation, testing & commissioning of 25mm dia MS C Class fuel supply and return piping from diesel day oil tank to the DG Set, including all necessary fittings like tees, bends, ball valves etc. complete in all respects as per the specifications. 579 Providing and fixing of Valves and NRV for fuel line of following sizes: 580 40mm ball valve 581 25mm ball valve 582 40mm NRV valve 583 25mm NRV valve 584 BOUNDARY WALL WITH GATES 585 CARRIAGE OF MATERIALS 586 Carriage of good earth by mechanical transport including loading, unloading and stacking (upto 20KM) 587 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge. All kinds of soil 588 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. 589 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) 590 Centring and shuttering including strutting,propping etc. and removal of form for 591 Foundations, footings, bases of columns etc. for mass concrete. 592 Lintels, beams, plinth bams, griders, bressumers and cantilevers. 593 Columns,Pillars, Piers, Abutments, Posts and Struts 594 Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete upto plinth & above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. 595 Steel reinforcement for R.C.C. work including straightening, cutting, bending,placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. 596 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. 597 All works upto plinth level Concrete of M25 grade with minimum cement content of 330 kg /cum 598 All works above plinth level upto floor V level Concrete of M25 grade with minimum cement content of 330 kg /cum 599 Boring with hydraulic piling rigs with power units, providing and installing cast in situ single under reamed piles of specified diameter and length below pile cap in M-25 cement concrete, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and the length of the pile to be embedded in pile cap etc. all complete. (Length of pile for payment shall be measured upto to the bottom of pile cap) : 600 300 mm dia piles 601 Extra over single under ream for providing additional bulbs in under reamed piles, under specified diameter(only the nos. of extra bulbs are to be paid) 602 300 mm dia piles 603 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand) 604 Providing and laying Autoclaved Aerated concrete(AAC) blocks masonry with 150mm to 300 mm thick with Grade-1 AAC blocks of density 551 to 650 kg/cum conforming to IS:2185 (Part 3) in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately). 605 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. 606 Hot finished welded type tubes 607 Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. 608 In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works 609 18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster 1:6 (1 cement : 6 fine sand). 610 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 611 Painting with synthetic enamel paint of approved brand and manufacture of required color to give an shade. Two or more coats on new work including priming coat of ordinary paint approved brand. 612 Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm 613 Providing & fixing galvanized low carbon wire, anealed wire Chicken mesh formed by twisting two adjacent wires at least four times, forming a hexagonal shaped strong honeycomb mesh structure on joints of RCC & Brick work before plastering, of required gauge (not less than 21 gauge)and size with nails etc. complete as specified in drawing and as per the Direction of Engineer-in-charge. 614 Providing and fixing dry cladding upto 10 metre heights with 30mm thick gang saw cut stone with machine cut edges of uniform colour and size upto 1mx1m, fixed to structural steel frame work and/ or with the help of cramps, pins etc. and sealing the joints with approved weather sealant as per Architectural drawing and direction of Engineer-in-charge. (The steel frame work, stainless steel cramps and pins etc. shall be paid for separately). 615 White sand stone - 30mm thick gang saw cut stone 616 Providing and fixing structural steel frame (for dry cladding with 30 mm thick gang saw cut with machine cut edges sand stone) on walls at all heights using M.S. square/ rectangular tube in the required pattern as per architectural drawing, including cost of cutting, bending, welding etc. The frame work shall be fixed to the wall with the help of M.S. brackets/ lugs of angle iron/ flats etc. which shall be welded to the frame and embedded in brick wall with cement concrete block 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20 mm nominal size) of size 300x230x300mm, including cost of necessary centring and shuttering and with approved expansion hold fasteners on CC/RCC surface, including drilling necessary holes. Approved cramps/ pins etc. shall be welded to the frame work to support stone cladding, the steel work will be given a priming coat of Zinc primer as approved by Engineer-in-charge and painted with two or more coats of epoxy paint (Shop drawings shall be submitted by the contractor to the Engineer-incharge for approval before execution). The frame work shall be fixed in true horizontal & vertical lines/planes. (Only structural steel frame work shall be measured for the purpose of payment, stainless steel cramps shall be paid for separately and nothing extra shall be paid). 617 Providing and fixing adjustable stainless steel cramps of approved quality, required shape and size, adjustable with stainless steel nuts, bolts and washer (total weight not less than 260 gms), for dry stone cladding fixed on frame work at suitable location, including making necessary recesses in stone slab, drilling required holes etc complete as per direction of the Engineer-incharge. 618 Applying breathable, non-reactive, antifungal, and water repellant Silane/Siloxane chemical as approved by Archaeological Survey of India/ Engineer-in-charge, of approved brand and manufacture, diluted with solvent mineral Turpentine oil in the ratio of 1:12 (One part of approved chemical :12 Part of Turpentine oil), on the existing sand stone masonry surface with two or more coats to give uniform application of chemical on the surface, all complete as per direction of Engineer-In-charge (The rate is inclusive of all materials & labours involved except scaffolding). 619 ESS 620 Carriage of good earth by mechanical transport including loading, unloading and stacking (upto 20KM) 621 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge. 622 All kinds of soil 623 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. 624 Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. 625 Supplying chemical emulsion in sealed containers including delivery as specified. 626 Chlorpyriphos/ Lindane emulsifiable concentrate of 20% 627 Diluting and injecting chemical emulsion for pre-constructional anti-termite treatment (excluding the cost of chemical emulsion) :Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor : With Chlorpyriphos/Lindane E.C. 20% with 1% concentration. 628 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) 629 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) 630 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. 631 Centring and shuttering including strutting,propping etc. and removal of form for 632 Foundations, footings, bases of columns etc. for mass concrete. 633 Suspended floors, roots, landings, balcnies and access platform. 634 Shelves (Cost in situ) 635 Lintels, beams, plinth bams, griders, bressumers and cantilevers. 636 Columns,Pillars, Piers, Abutments, Posts and Struts 637 Weather shade, Chajjas, corbels etc., including edges 638 Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc. including cost of de-shuttering and decentering at all levels, over a height of 3.5 m, for every additional height of 1 metre or part thereof (Plan area to be measured) Suspended floors, roofs, landing, beams and balconies (Plan area to be measured). 639 Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete upto plinth & above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. 640 Steel reinforcement for R.C.C. work including straightening, cutting, bending,placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. 641 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. 642 All works upto plinth level 643 Concrete of M25 grade with minimum cement content of 330 kg /cum 644 All works above plinth level upto floor V level 645 Concrete of M25 grade with minimum cement content of 330 kg /cum 646 Boring with hydraulic piling rigs with power units, providing and installing cast in situ single under reamed piles of specified diameter and length below pile cap in M-25 cement concrete, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and the length of the pile to be embedded in pile cap etc. all complete. (Length of pile for payment shall be measured upto to the bottom of pile cap) :300 mm dia piles 647 Extra over single under ream for providing additional bulbs in under reamed piles, under specified diameter(only the nos. of extra bulbs are to be paid) 648 300 mm dia piles 649 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: 650 Cement mortar 1:6 (1 cement : 6 coarse sand) 651 Providing and laying Autoclaved Aerated concrete(AAC) blocks masonry with 150mm to 300 mm thick with Grade-1 AAC blocks of density 551 to 650 kg/cum conforming to IS:2185 (Part 3) in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately). 652 Providing and laying Autoclaved Aerated concrete(AAC) blocks masonry 100mm/125mm thick with Grade-1 AAC blocks of density 551 to 650 kg/cum conforming to IS:2185 (Part 3) in super structure above plinth level up to floor V level in cement mortar 1:4 (1 cement : 4 coarse sand). The rate includes providing and placing in position 2 Nos 6 mm dia M.S. bars at every third course of masonry work. 653 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. 654 Hot finished welded type tubes 655 Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 656 80x1.25 mm M.S. laths with 1.25 mm thick top cover 657 Providing and fixing ball bearing for rolling shutters. 658 Extraforprovidingmechanicaldevice chain andcrankoperation for operating rolling shutters. 659 Exceeding 10.00 sqm and upto 16.80 sqm in the area. 660 Extra for providing grilled rolling shutters manufactured out of 8mm dia.M.S. bar instead of laths as per design approved by Engineer-in-charge.(area of grill to be measured). 661 Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 662 25 mm thick 663 Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. 664 15 mm cement plaster on the rough side of single or half brick wall of mix : 665 1:6 (1 cement: 6 coarse sand) 666 18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster 1:6 (1 cement : 6 fine sand). 667 6 mm cement plaster of mix : 668 1:3 (1 cement : 3 fine sand) 669 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 670 Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour : New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre 671 Painting with synthetic enamel paint of approved brand and manufacture of required color to give an shade. 672 Two or more coats on new work including priming coat of ordinary paint approved brand. 673 Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm 674 Providing & fixing galvanized low carbon wire, anealed wire Chicken mesh formed by twisting two adjacent wires at least four times, forming a hexagonal shaped strong honeycomb mesh structure on joints of RCC & Brick work before plastering, of required gauge (not less than 21 gauge)and size with nails etc. complete as specified in drawing and as per the Direction of Engineer-in-charge. 675 Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations:(a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment.(b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs.(c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineering-charge.(d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineering-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep.(e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by the Engineer-in-Charge :With average thickness of 120 mm and minimum thickness at khurra as 65mm. 676 Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : 677 In 75x75 mm deep chase 678 Providing and fixing Heat Resistant Terrace Tiles (300 mm x 300 mm x 20 mm) with SRI (solar refractive index) > 78, solar reflection > 0.70 and initial emittance > 0.75 on waterproof and sloped surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1:4 (1 cement : 4 coarse sand) and grouting the joints with mix of white cement & marble powder in ratio of 1:1, including rubbing and polishing of the surface upto 3 cuts complete, including providing skirting upto 150 mm height along the parapet walls in the same manner. 679 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS : 1285, fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC/neoprene felt etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing and paneling to be paid for separately) : For fixed portionPowder coated aluminium (minimum thickness of powder coating 50 micron) 680 For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of PVC / neoprene gasket required (Fittings shall be paid for separately). 681 Powder coated aluminium (minimum thickness of powder coating 50 micron) 682 Providing and fixing 6 mm thick high performance toughened glass from approved manufacturer complete in all respects as per direction of the Engineer-in-charge. (Required properties Solar factor 0.43, U-Value (W/sq.m-K) 5.6, Visible light transmittance 0.43). The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement. 683 GUARD ROOM 684 Carriage of good earth by mechanical transport including loading, unloading and stacking 685 (upto 20KM) 686 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge. 687 All kinds of soil 688 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. 689 Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. 690 Supplying chemical emulsion in sealed containers including delivery as specified. Chlorpyriphos/ Lindane emulsifiable concentrate of 20% 691 Diluting and injecting chemical emulsion for pre-constructional anti-termite treatment (excluding the cost of chemical emulsion) : Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor : With Chlorpyriphos/Lindane E.C. 20% with 1% concentration. 692 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) 693 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) 694 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. 695 Centring and shuttering including strutting,propping etc. and removal of form for 696 Foundations, footings, bases of columns etc. for mass concrete. 697 Suspended floors, roots, landings, balcnies and access platform. 698 Shelves (Cost in situ) 699 Lintels, beams, plinth bams, griders, bressumers and cantilevers. 700 Columns,Pillars, Piers, Abutments, Posts and Struts 701 Edges of slabs and breaks in floors and walls Under 20 cm wide 702 Weather shade, Chajjas, corbels etc., including edges 703 Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete upto plinth & above plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more. 704 Steel reinforcement for R.C.C. work including straightening, cutting, bending,placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. 705 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. 706 All works upto plinth level 707 Concrete of M25 grade with minimum cement content of 330 kg /cum 708 All works above plinth level upto floor V level 709 Concrete of M25 grade with minimum cement content of 330 kg /cum 710 Boring with hydraulic piling rigs with power units, providing and installing cast in situ single under reamed piles of specified diameter and length below pile cap in M-25 cement concrete, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and the length of the pile to be embedded in pile cap etc. all complete. (Length of pile for payment shall be measured upto to the bottom of pile cap) : 711 300 mm dia piles 712 Extra over single under ream for providing additional bulbs in under reamed piles, under specified diameter(only the nos. of extra bulbs are to be paid) 713 300 mm dia piles 714 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: 715 Cement mortar 1:6 (1 cement : 6 coarse sand) 716 Providing and laying Autoclaved Aerated concrete(AAC) blocks masonry with 150mm to 300 mm thick with Grade-1 AAC blocks of density 551 to 650 kg/cum conforming to IS:2185 (Part 3) in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately). 717 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 718 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws 719 Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). 720 Extra for providing vision panel not exceeding 0.1 sqm in all type of flush doors (cost of glass excluded) (overall area of door shutter to be measured): 721 Rectangular or square. 722 Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality. 723 1.0 mm thick 724 Providing and fixing approved brand and manufacture SS 304 Lever Handle D-type, 22mm dia fixed with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 725 Providing and fixing approved brand and manufacture SS 304 grade SS 304 grade Mortise Dead Lock with 60mm Backset fixed fixed with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 726 Providing and fixing approved brand and manufacture SS 304 grade Tower bolt 250mm long with 10mm dia fixed with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 727 Providing and fixing approved brand and manufacture SS 304 grade wall mounted door buffer fixed with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 728 Providing and fixing approved brand and manufacture SS 304 grade Door Stopper - door mounted hanging type fixed with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 729 Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISi, IS : 3564, embossed on the body, door weight upto 36kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete. 730 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. Glazed Vitrified tiles Matt/Antiskid finish of size Size of Tile 600 x 600 mm 731 Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600 x 600 mm 732 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite of any colour and shade 733 Area of slab upto 0.50 sqm 734 Area of Slab over 0.50sqm 735 Extra for providing edge moulding to 18mm thick marblestone counters, Vanities etc. including machine polishing to edge to give high glossfinishetc.completeasper designapprovedbyEngineer-in-Charge. 736 Granite work. 737 Extra for fixing marble /granite stone over and abovecorresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive including cleaning etc. complete. 738 15 mm cement plaster on the rough side of single or half brick wall of mix : 739 1:6 (1 cement: 6 coarse sand) 740 18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster 1:6 (1 cement : 6 fine sand). 741 6 mm cement plaster of mix : 742 1:3 (1 cement : 3 fine sand) 743 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 744 Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour : 745 New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre 746 Painting with synthetic enamel paint of approved brand and manufacture of required color to give an shade. 747 Two or more coats on new work including priming coat of ordinary paint approved brand. 748 Finishing walls with textured exterior paint of required shade :New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm 749 Providing & fixing galvanized low carbon wire, anealed wire Chicken mesh formed by twisting two adjacent wires at least four times, forming a hexagonal shaped strong honeycomb mesh structure on joints of RCC & Brick work before plastering, of required gauge (not less than 21 gauge)and size with nails etc. complete as specified in drawing and as per the Direction of Engineer-in-charge. 750 Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturers specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : 751 12.5 mm thick tapered edge gypsum moisture resistant board 752 Providing and fixing false ceiling at all heights with integral densified calcium silicate reinforced with fibre and natural filler false ceiling tiles of Size 595x595mm of approved texture, design and patterns as per CPWD Specification 2019, to be laid in true horizontal level suspended on inter-locking metal T-Grid of hot dipped galvanised iron section of 0.33mmthick (galvanized @ 120 grams per sqm including both sides)comprising of main-T runners of size 24x38 mm of length 3000 mm, cross - T of size 24x32 mm of length 1200 mm and secondary intermediate cross-T of size 24x32 mm of length 600mm to form grid module of size 600 x 600 mm, suspended from ceiling using galvanised mild steel items (galvanizing @ 80 grams per sqm) i.e. 12x50 mm long dash fasteners, 6 mm dia fully threaded hanger rod upto 1000 mm length and L-shape level adjuster of size 76x25x25x1.6mm fixed with grid and Z cleat of size 25x37x25x1.6mm thick with precut hole on both 25mm flange to pierce into 12x50mm or even bigger size dash fastener if require, fixed with Glavanised iron perimeter wall angle or size 24x24x0.40 mm of length 3000 mm to be fixed on periphery wall / partition with the help of plastic rawl plugs at 450mm center to center and 40 mm long dry wall S.S screws. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in-Charge. 753 With 15 mm thick Tegular edged light weight calcium silicate false ceiling tiles 754 Providing and fixing tiled false ceiling of approved materials of size 595x595 mm in true horizontal level suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 gsm/sqm, both side inclusive) consisting of main T runner with suitably spaced joints to get required length and of size 24x38mm made from 0.30mm thick (minimum) sheet, spaced at 1200mm center to center and cross T of size 24x25mm made of 0.30mm thick (minimum) sheet, 1200mm long spaced between main T at 600mm center to center to form a grid of 1200x600 mm and secondary cross T of length 600mm and size 24x25mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600mm panel to form grids of 600x600mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, wherever, required, cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main T runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 x mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete at all heights as per specifications drawings and as directed by Engineer-in-charge.GI Metal Ceiling Lay in perforated Tegular edge global white color tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/sqm (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient ) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fiber acoustical fleece. 755 Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations:(a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment.(b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs.(c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineering-charge.(d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineering-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep.(e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by the Engineer-in-Charge :With average thickness of 120 mm and minimum thickness at khurra as 65mm. 756 Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design :In 75x75 mm deep chase 757 Providing and fixing Heat Resistant Terrace Tiles (300 mm x 300 mm x 20 mm) with SRI (solar refractive index) > 78, solar reflection > 0.70 and initial emittance > 0.75 on waterproof and sloped surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1:4 (1 cement : 4 coarse sand) and grouting the joints with mix of white cement & marble powder in ratio of 1:1, including rubbing and polishing of the surface upto 3 cuts complete, including providing skirting upto 150 mm height along the parapet walls in the same manner. 758 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS : 1285, fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC/neoprene felt etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing and paneling to be paid for separately) :For fixed portionPowder coated aluminium (minimum thickness of powder coating 50 micron) 759 For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of PVC / neoprene gasket required (Fittings shall be paid for separately). 760 Powder coated aluminium (minimum thickness of powder coating 50 micron) 761 Providing and fixing 6 mm thick high performance toughened glass from approved manufacturer complete in all respects as per direction of the Engineer-in-charge. (Required properties Solar factor 0.43, U-Value (W/sq.m-K) 5.6, Visible light transmittance 0.43). The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement. 762 UNDER GROUND TANK (UGT) 763 Carriage of good earth by mechanical transport including loading, unloading and stacking 764 (upto 20KM) 765 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge. 766 All kinds of soil 767 Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials. 768 All kinds of soil (From 1.5 to 3 m depth) 769 All kinds of soil (From 3.00 to 3.50 m depth) 770 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. 771 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) 772 Centring and shuttering including strutting,propping etc. and removal of form for 773 Foundations, footings, bases of columns etc. for mass concrete. 774 Walls (any thickness) including attached pilasters. Butteresses, plinth and string courses etc. 775 Suspended floors, roots, landings, balcnies and access platform. 776 Shelves (Cost in situ) 777 Lintels, beams, plinth bams, griders, bressumers and cantilevers. 778 Columns,Pillars, Piers, Abutments, Posts and Struts 779 Stairs, (excluding landings) except spiral-staircases 780 Edges of slabs and breaks in floors and walls 781 Under 20 cm wide 782 Weather shade, Chajjas, corbels etc., including edges 783 Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete upto plinth & above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. 784 Steel reinforcement for R.C.C. work including straightening, cutting, bending,placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. 785 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. 786 All works upto plinth level 787 Concrete of M25 grade with minimum cement content of 330 kg /cum 788 All works above plinth level upto floor V level 789 Concrete of M25 grade with minimum cement content of 330 kg /cum 790 Providing and laying Autoclaved Aerated concrete(AAC) blocks masonry with 150mm to 300 mm thick with Grade-1 AAC blocks of density 551 to 650 kg/cum conforming to IS:2185 (Part 3) in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately). 791 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 792 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws 793 Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). 794 Extra for providing vision panel not exceeding 0.1 sqm in all type of flush doors (cost of glass excluded) (overall area of door shutter to be measured): 795 Rectangular or square. 796 Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality. 797 1.0 mm thick 798 Providing and fixing approved brand and manufacture SS 304 Lever Handle D-type, 22mm dia fixed with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 799 Providing and fixing approved brand and manufacture SS 304 grade SS 304 grade Mortise Dead Lock with 60mm Backset fixed fixed with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 800 Providing and fixing approved brand and manufacture SS 304 grade Tower bolt 250mm long with 10mm dia fixed with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 801 Providing and fixing approved brand and manufacture SS 304 grade wall mounted door buffer fixed with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 802 Providing and fixing approved brand and manufacture SS 304 grade Door Stopper - door mounted hanging type fixed with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 803 Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISi, IS : 3564, embossed on the body, door weight upto 36kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete. 804 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. 805 Hot finished welded type tubes 806 Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 807 25 mm thick 808 Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. 809 Extra for pre finished nosing to treads of steps of Kota/Sand stone. 810 Extra for Kota/Sand flooring in treads of steps and risers using single length above normal size up to 2.00 metre . 811 Providing and fixing 1st quality ceramic glazed floor tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. 812 Providing and laying matt finished vitrified tile of size 300x300x9.8mm having with water absorption less than 0.5% and conforming to IS: 15622 of approved make in all colours and shades in for outdoor floors such as footpath, court yard, multi modals location etc., laid on 20mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as per direction of Engineer-in-Charge. 813 Providing and laying rectified Glazed Ceramic floor tiles of size 300x300mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement: 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/sqm including grouting the joints with white cement and matching pigments etc., complete. 814 12mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand) 815 18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster 1:6 (1 cement : 6 fine sand). 816 6 mm cement plaster of mix : 1:3 (1 cement : 3 fine sand) 817 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 818 Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour :New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre 819 Painting with synthetic enamel paint of approved brand and manufacture of required color to give an shade.Two or more coats on new work including priming coat of ordinary paint approved brand. 820 Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm 821 Providing & fixing galvanized low carbon wire, anealed wire Chicken mesh formed by twisting two adjacent wires at least four times, forming a hexagonal shaped strong honeycomb mesh structure on joints of RCC & Brick work before plastering, of required gauge (not less than 21 gauge)and size with nails etc. complete as specified in drawing and as per the Direction of Engineer-in-charge. 822 Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations:(a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment.(b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs.(c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineering-charge.(d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineering-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep.(e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by the Engineer-in-Charge : 823 In 75x75 mm deep chase 824 Providing and fixing Heat Resistant Terrace Tiles (300 mm x 300 mm x 20 mm) with SRI (solar refractive index) > 78, solar reflection > 0.70 and initial emittance > 0.75 on waterproof and sloped surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1:4 (1 cement : 4 coarse sand) and grouting the joints with mix of white cement & marble powder in ratio of 1:1, including rubbing and polishing of the surface upto 3 cuts complete, including providing skirting upto 150 mm height along the parapet walls in the same manner. 825 Road Work 826 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 827 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) 828 Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by Engineer-in- Charge: 829 All kinds of soil 830 Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earth with lead upto 50 metres. 831 Extra for compaction of earth work in embankment under optimum moisture conditions to give at least 95% of the maximum dry density (proctor density). 832 Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge. 833 With material conforming to Grade-I (size range 75 mm to 0.075 mm) having CBRValue-30 834 Providing, laying, spreading and compacting graded stone aggregate (size range 53 mm to 0.075 mm ) to wet mix macadam (WMM) specification including premixing the material with water at OMC in for all leads & lifts, laying in uniform layers with mechanical paver finisher in sub- base / base course on well prepared surface and compacting with vibratory roller of 8 to 10 tonne capacity to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge. 835 Providing and laying 400 micron thick PVC Sheet on WBM Surface complete as per direction of engineer-in-charge. 836 Providing and laying C.C. pavement of mix M-25 with ready mixed concrete from batching plant. The ready mixed concrete shall be laid and finished with screed board vibrator , vacuum dewatering process and finally finished by floating, brooming with wire brush etc. complete as per specifications and directions of Engineer-in-charge. (The panel shuttering work shall be paid for separately).(Note:- Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/ recoverable separately). 837 Providing and fixing pre-moulded joint filler in expansion joints of RCC roads / CC pavements after making the joints dust free with high pressure air jet cleaners, all complete as per direction of the Engineer-in-Charge. (Pre-moulded joint fillers shall be made of bitumen hot sealing compound impregnated fibre board having impregnation more than 35%, conforming to IS:1838 for fibre board and IS: 1834 for hot sealing bitumen compound grade A.) 838 Providing and filling in position rubberized bitumen hot sealing compound for sealing of expansion joints in roads / pavements all complete as per direction of the Engineer-in-Charge. Using grade A sealing compound conforming to IS: 1834. 839 Painting runway/taxi track/apron marking with adequate no. of coats to give uniform finish with road marking paint of superior make as approved by the Engineer-in-charge i/c cleaning the surface of all dirt, scales, oil, grease and other foreign material etc. and lining out complete 840 New work (Two or more coats) 841 Providing and laying at or near ground level factory made kerb stone of M-25 grade cement in position to the required line , level and curvature jointed with cement mortar 1:3 (1 cement : 3 coarse sand) including making joints with or without grooves (thickness of joints except sharp curve shall not be more than 5mm) including making drainage opening wherever required complete etc. as per direction of engineer-in-charge (length of finished kerb edging shall be measured for payment).(Precast C.C. kerb stone shall be approved by engineer-in-charge). 842 FOOTPATH & STONE BENCHES 843 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge. 844 All kinds of soil 845 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 846 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) 847 Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete upto plinth & above plinth level. 848 Thermo-Mechanically Treated bars of grade Fe-500D or more. 849 Providing, hoisting and fixing above plinth level up to floor five level precast reinforced cement concrete work in string courses, bands, copings, bed plates, anchor blocks, plain window sills and the like, including the cost of required centering, shuttering but , excluding cost of reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). 850 Providing and fixing 70 mm thick Lalitpur Grey sand stone over prefix sand stone legs including polishing, pointing with cement mortar 1:2 (1 cement : 2 stone dust) with an admixture of pigment to match the shade of stone. 851 Providing and fixing 10x10x7.50 cm Granite stone block hand cut and chisel dressed on top, for paving in floors, drains etc. laid over 20mm thick base mortar 1:4 (1 cement : 4 coarse sand) with joints 10mm wide filled with same mortar including ruled pointing etc. complete as per direction of engineer-in-charge. 852 Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by Engineer-in- Charge: 853 All kinds of soil 854 Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earth with lead upto 50 metres. 855 Extra for compaction of earth work in embankment under optimum moisture conditions to give at least 95% of the maximum dry density (proctor density). 856 Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge. 857 With material conforming to Grade-I (size range 75 mm to 0.075 mm) having CBRValue-30 858 Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. 859 60mm thick cement concrete paver block of M-35 grade with approved colour, design & pattern. 860 HORTICULTURE & LANDSCAPING WORK 861 Trenching in ordinary soil up to a depth of 60 cm including removal and stacking of serviceable materials and then disposing of surplus soil, by spreading and neatly levelling within a lead of 50 m and making up the trenched area to proper levels by filling with earth or earth mixed with sludge or/and manure before and after flooding trench with water (excluding cost of imported earth, sludge or manure). 862 Supplying and stacking of good earth at site including royalty and carriage up to 1 km (earth measured in stacks will be reduced by 20% for payment). 863 Supplying and stacking at site dump manure from approved source, including carriage up to 1 km (manure measured in stacks will be reduced by 8% for payment) : 864 Screened through sieve of I.S. designation 20 mm 865 Screened through sieve of I.S. designation 16 mm 866 Screened through sieve of I.S. designation 4.75 mm 867 Fine dressing of the ground 868 Spreading of sludge, dump manure and / or good earth in required thickness as per direction of Officer-in-charge (Cost of sludge, dump manure and / or good earth to be paid separately). 869 Mixing earth and sludge or manure in the required proportion specified or directed by the Officer-in-charge.. 870 Providing and laying Neelgiri/Korean grass turf with earth 50mm to 60mm thickness of existing ground prepared with proper level and ramming with tools wooden (Dhurmos) and than rolling the surface with light roller make the surface smoothen and light watering with sprinkler and maintenance for 30 days or more till the grass establish properly, as per direction of officer-in-charge. 871 Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts (cost of manure, sludge or extra good earth if needed to be paid for separately) : 872 Holes 60 cm dia, and 60 cm deep. 873 Holes 45 cm dia, and 45 cm deep. 874 TREE PLANTS 875 Providing and stacking of Cassia fistula (Amaltash) of height 120-135 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge. 876 Providing and stacking of Bauhinia purpurea (Kachnar) of height 150-165 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge. 877 Providing and stacking of Azadirachta indica ( Neem ) of height 120-130cm in big polybag of size 25 cm as per direction of the officer-in-charge. 878 Providing and stacking of Mimusops elengi (Maulsri) of height 180-195 cm., well developed with thick stem in big in big size HDPE bag as per direction of the officer-in-charge. 879 Providing and stacking of Callistemon lanceolatus of height 150-165 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge. 880 Providing and stacking of Saraca indica (Sita Ashok) of height 105-120cm. in big poly bags of size 25 cm as per direction of the officer-in-charge. 881 GROUND COVERS PLANTS 882 Providing and stacking of Tradescantia, full of leaves in Earthen Pot/Plastic Pot of size 15 cm. as per direction of the officer-in-charge. 883 Providing and stacking of Wedelia trilobata,full of leaves in 15 cm size of Earthen Pot/Plastic Pot & as per direction of the officer-in-charge. 884 Providing and stacking of Syngonium golden of height 30-45 cm. with 2-3 suckers healthy foliage in Earthen Pot/Plastic Pot of size 20 cm. as per direction of the officer-in-charge. 885 SHRUBS AND PERINNIAL HERBS 886 Providing and Displaying Bougainvillea named variety, Sobhra, Thima, Marry palmar, Cherry Blossom etc. well developed with fresh & healthy bushy in full bloom 75 to 90 cm ht. in 40 cm Cement Pot as per direction of the officer-in-charge. 887 Providing and stacking of Cassia biflora of height 90-105 cm., well branched, bushy in big size HDPE bag as per direction of the officer-in-charge. 888 Providing and stacking of Ficus panda of height 60-75 cm, with 8-10 branches, and healthy foliage, bushy in big size HDPE bag as per direction of the officer-in-charge. 889 CREEPER PLANTS 890 Providing and stacking of Quisqualis indicia of height 30 cm to 45 cm. in 20 cm size of Earthen pots / Plastic pots & as per direction of the officer-in-charge. 891 Providing and stacking of Clerodendrum splendens of height 30 cm to 45cm. in 20 cm size of Earthen pots / Plastic pots & as per direction of the officer-in-charge. 892 FURNITURE AND FURNISHINGS 893 Cafe Table, S.S. Pipe Frame, PLPB Edge Banded Top, 38mm Thick, Size in mm - 900mm (Dia.) 894 Café Chair, PP Seat & Back 895 DiningTable, Powder Coated + Chrome Plated Pipe Frame, PLPB Edge Banded Top, 25mm Thick, Size in mm - 1500 X 900 896 Medium Back Chair, PU Arms, Silver Powder Coated Pipe Frame,Gas Lift, Powder Coated Base, Seat Back Leatherite Tapestry. 897 Reception Table, Particle Board Top 898 2 Seater Sofa With Wooden Frame, Powder Coated Leg, Twin Colour Leatherette Tapestry Size in mm - 1180 (L) X 835 (D) X 785 (H) 899 Centre Table, 18mm PLPB Top, Annodize Aluminium Section Frame 900 Corner Table, MDF Top With Veneer Polish, MS Gold Finish Leg 901 1 Seater Sofa With Wooden Frame, Powder Coated Leg, Twin Colour Leatherette Tapestry Size in mm - 810 (L) X 835 (D) X 785 (H) 902 Medium Back Chair, Wooden Frame, Cushion Arm, Synchro Knee Tilt, Gas Lift, Aluminium Base 903 Visitor Chair, Wooden Frame, Cushion Arm, Chrome Plated pipe stand 904 Executive Table, PLPB Top, Flaper Box, Extruded Aluminium Profile 905 Conference Table, Particle Board Edge Banded Top 906 Medium Back Chair, PP Cushion Arm, Swivel Tilt, Gas Lift, Nylon Base 907 Executive Table, Particle Board Top, Fixed Metal Pedestal, Metal Frame, Powder Coated 908 Visitor Chair, Cushion Arm, PU Moulded Seat Back, Chrome Plated Pipe stand 909 Bunk Bed, CRCA Pipe Frame, Powder Coated, PPCP Shoes, With 12mm Plywood, Without Mattress Uppder Size- 1950 X 965 Lower Size- 1950 X 1250 910 Study Table, Particle Board Top, MS Powder Coated Legs 911 METAL BED 912 WARDROBE WITH MIRROR ,PLPB BOARD 913 SUBHEAD I-EARTHING 914 Supply and burying of 40mm dia x 4.5 metres long G.I. Pipe vertically for earthing having 12mm dia. Holes spaced 75mm apart drilled up to 2 metre from the bottom complete with earthing lead of No. 6 to 8 SWG GI wire in G.I. Pipe up to appron (and from appron to switch board the cost of G.I. wire and pipe will be extra) upto switch board, 30cm square C.I. box with hinged cover masonary enclosure, funnel at top, alternate layers of charcoal/coke and salt at least 150mm thick alround etc. as per directions of Engineer-in-charge complete in all respects as per drawing. 915 Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required 916 Supply and burying of 600mm x 600mm x 3mm copper plate vertically for earthing with its top at least 3 metres below ground level complete with 20mm dia G.I. pipe and funnel for watering and two earthing lead of two no. 8 SWG copper wire in 15mm dia G.I. pipe up to switch board (from appron to switch board the cost of G.I. pipe and copper wire will be extra) 30cm square C.I. frame with hinged cover masonry housing alternate layers of charcoal/coke and salt at least 150mm thick alround etc. complete in 917 all respects. 918 Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) 919 Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge ,complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. 920 50 sqmm3.5 core 921 6 sqmm3 core 922 6 sqmm2 core 923 Supply & fixing of brass nickle plated compression gland for PVC insulated & armoured served sheathed, underground cable including rubber ring etc. complete in all respects. The armouring of the cable shall be properly connected with the earth as per dire 924 50 sqmm3.5 core 925 6 sqmm3 core 926 6 sqmm2 core 927 Supplying and fixing of Palm / pin type copper tin plated cables sockets (lugs) to the cable leads, insuslating with tape and making of connections etc. complete in all respects as per direction of Engineer-Incharge. 928 50 sqmm 929 GST Extra as per applicable
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Uttar Pradesh View Result →
25.
Public Administrative Department #9468133 Technical Bid
Tender For Coating work on the drain constructed by District Panchayat Deera from Gram Sabha Amr Khaira Marg through Padmavati Mahila Mahavidyalaya - Construction of embankment with approved material obtained from borrow pits with a lift upto 1.5 m, transporting to site, spreading, grading to required slope and compacting to meet requirement of Tables 300.1 and 300.2 with a lead upto 1000 m as per Technical Specification Clause 301.5 2 Construction of granular sub-base by providing well graded material, spreading in uniform layers with tractor mountedgrader on prepared surface mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401. 3 Providing laying spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing rolling with 3-wheeled steel/vibratory roller 8-10 tonnes in stages to proper grade and camber, applying and brooming requisite type of screening/binding materials to fill-up the interstices of coarse aggregate, watering and compacting to the required density. G-2 as per technical specification clause 405 4 Providing laying spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing rolling with 3-wheeled steel/vibratory roller 8-10 tonnes in stages to proper grade and camber, applying and brooming requisite type of screening/binding materials to fill-up the interstices of coarse aggregate, watering and compacting to the required density.G-3 as per technical specification clause 405 5 Brickedging on both side of the road of brick class M-150, 8 cm wide and 12 cm deep etc.( As per SOR, Schedule item no.765) 6 Providing and applying primer coat with bitumen emulsion(SS-1) on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.70-1.0 kg/sqm using mechanical means as per technical means 502 7 Providing and applying tack coat with bitumen VG-10 usingbitumen pressure distributor at the rate of 0.35 kg per sqm on the prepared dry and hungry bituminous surface cleaned with hydraulic broom as per technical specicification Clause 503. 8 Providing & laying 20mm thick P.C. overexisting WBM surface and including p/l of Prime Coat @ 0.75Kg./Sqm & Tack Coat @ 0.35Kg./Sqm by bitumen emlusion, With graded approved quarry grit (0.018Cum 13.2mm nominal size and 0.009cum 11.2mm nominal size grit and as per P.W.D. specification as per direction of E/I. 9 Cleaning the Premix surface and laying Seal Coat of graded 2.36mm nominal size approved quarry grit @ 0.006cum per Sqm with 80/100 bitumen @ 0.68Kg./Sqm including heating the bitumen to required temp. including cost of grit, labour, T&P for proper completion of work. As per P.W.D. specification & as per direction of E/I. 10 SUPPLY AND PAINTAING OF THERMO PLASTIC ROAD MARKING ON THE PAINTED ROAD SURFACE ST THE CENTRE LINE AND BOTH EDGE OF THE ROAD IN DIVIDER PORTION 11 Providing and laying reuniforced cement concrete NP-3 for culvert on first class bending of granuar material in single row including fixing coller with cement mortar 1:2 but excluding excavtion protection works backfilling concrete and masonary 350 mm NP-3 Hume pipe 12 Supply & Fixing of Sign Board
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 3
Uttar Pradesh View Result →
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 3
Maharashtra View Result →
27.
Health and Family Welfare #9371992 AOC
Tender For Purchase Of Laboratory Consumables Items; 1 Chemical, Kits,Antibiotic Disc, Culture Media, ANA Kits Etc., 2 ANA Profile et Mi-2, Ku-16x01 3 ANA Kit IIFT Mosaic: Hep-20-10/Liver (monkey) (5 TEST * 10 SLIDES) 4 ANA Blot Assay With 18 Parameters 20 Strip Pack 5 VIDASHBe/ Anti HBe 6 VIDASAnti HBc 7 VIDASHAV IgM 8 VIDASHEV IgM 9 VIDAS Anti HBs 10 VIDAS Anti-HCV 11 VIDAS Rubella IgG 12 VIDAS Rubella IgM 13 VIDAS CMV IgG 14 VIDAS CMV IgM 15 VIDAS Measels IgG 16 VIDAS Mumps IgG 17 VIDAS Vericella zoster IgG 18 VIDAS Procalcitonin (30 tests) 19 Hepatitis C Quantative RTPCR 20 Hepatitis B Quantative RTPCR 21 Human Papilloma Virus (16/18/67) RTPCR 22 Viral Encephalitis Meningitis Panel (HSV1&2 VZV,CMV,EBV, PARVOVIRUS V19, HUMAN PARECHOVIRUS, ENTEROVIRUS AND ADENOVIRUS) 23 Epstein Bar Virus (EBV) RTPCR 24 Cytomegalovirus (CMV) RTPCR 25 Zika virus RTPCR 26 Quantative Internal Control FOR Hepatitis B RTPCR (suitable for 50 reactions) 27 Quantative Internal Control FOR Hepatitis C RTPCR (suitable for 50 reactions) 28 Respiratory Panel RTPCR (INF A, INF B, H1N1,H3N2, ENTEROV, ADENOVIRUS, BOCAVIRUS, HMPV,PARECHOVIRUS, PARAINFLUENZA 1-4) 29 AMR PANEL ( MRSA-nuc, mecA, mecB, VRE-vanA, vanB, vanM; CRE- blaNDM,blaKPC,blaIMP, blaVIM, blaOXA48; Klebsiella , Pseudomonas, Acinetobacter) 30 Carbapenem resistance (blaNDM ,blaKPC, blaIMP, blaVIM, blaOXA48) 31 MRSA ( nuc, mecA, mecB) 32 VRE (vanA, vanB, vanM) 33 Egg yolk Agar 34 Mac Conkey Agar 35 Muller Hinton Agar 36 CLED Agar 37 Mannitol Salt Agar 38 Mannitol Motility Agar 39 Phenylethyl Alcohol Agar 40 Phenylalanine Agar 41 Pyrazinamidase Agar 42 Sheep Blood Agar Plates 43 Anaerobic Agar 44 Bacteroides Bile Esculin Agar 45 Phenyl Pyruvic Acid Agar 46 Tinsdale Media 47 Brucella agar base with hemin and vitamin K 48 Laked blood agar basewith kanamycin and vancomycin 49 Nutrient agar 50 Motility Sulphide Medium BASE 51 Glycine Powder 52 Lactose Powder 53 Lysine Decarboxylase Broth 54 Methyl Red Reagent (Prepared) 55 Maltose Powder 56 Mannitol Powder 57 Macconnkey Broth (Single Strength) 58 Ornithine Decarboxylase Broth 59 PYR Broth 60 Riboflavin Powder 61 Sucrose Powder 62 Staphylococcus Aureus ATCC Stain (ATCC-25923) 63 Klebsiella pneumonia ATCC Strain ( ATCC – 70063) 64 Transports Swab Stick W/ Amies Medium 65 Thioglycollate Broth Supplemented With Vit K 66 Tris Buffer Powder 67 Xylose Powder 68 Arginine Decarboxylase Broth 69 Anaerobic Gaspack 3.5L 70 Anaerobic Jar 3.5L 71 Anaerobic Gaspack 1.5L 72 Anaerobic Jar 1.5L 73 Anoxomat III Anaerobic Jar system 74 Straight Wire pack 75 Inoculationg Loop Metal Nichrome Wire pack 76 PCR mini cooler 77 Petridish Autoclavable Plastic 90 mm 78 Petridish Glass Ware 100mmx15mm Borosilicate 79 L-Butanol 80 Paradimethyl Aminobenzyldehyde 81 Isoamyl Alcohol 82 Malachite Green 83 Toluidine Blue 84 MR Regent 85 Nitrate Broth 86 Glucose (Dextrose) powder 87 Arabinose powder 88 Sucrose powder 89 Lactose powder 90 Mannitol powder 91 Inulin powder 92 Lysine Decarboxylase Broth 93 Ornithine Decarboxylase Broth 94 Arginine Decarboxylase Broth 95 Agar Agar Powder 96 Peptone Water 97 Glucose Powder 98 Agrose 99 Pipracillin- Tazabacum 10/10ug 100 Doxycyclin 30 ug 101 Cefoxtion 30 ug 102 Novobiocin 5 ug 103 Imipenem 10 ug 104 Chloramphenicol 30 ug 105 Cotrimoxazole 1.25/23.75 ug 106 Bacitracin 0.04 U 107 Cefexime 5mcg 108 Cefepime 30 mcg 109 Optochin 5 Mcg 110 Aztreonam 30 mcg 111 Ceftazidim - clavulanate 30/10 ug 112 Penicillin 100 units 113 ONPG 114 Meropenam 10 ug 115 Linezolid 30 ug 116 Tetracyclin 30 ug 117 Ceftriaxone 30 ug 118 Pefloxacin 5ug 119 High Level Gentamicin 120ug 120 Ceftriaxone 30ug 121 Cefuroxime 30ug 122 Cefixime 30ug 123 Cefoxitin 30ug 124 Meropenam 10ug. 125 Cefotaxime 30ug 126 Cefotaxmine / Clavulanic acid (30/10 ug) 127 HAV IgM ELISA (96 REACTIONS PER PACK) 128 HEV IgM ELISA (96 REACTIONS PER PACK) 129 HSV 1 & 2IgM ELISA (96 REACTIONS PER PACK) 130 HSV 1 & 2IgG ELISA (96 REACTIONS PER PACK) 131 FG OPTICAL ADHESIVE COVERS/FILM FOR RTPCR THERMO FISHER PLATES QUANT 5 STUDIO 132 BULK PACK 96 WELL RXN PLATES 0.2 MLFOR RTPCR THERMO FISCER QUANT 5 STUDIO 133 Compatible Optical Adhesive Covers/Film For RTPCR Plates Of BIORAD CFX 96 RTPCR 134 Compatible RTPCR Plates For BIORAD CFX 96 RTPCR 135 Dengue IgG ELISA kit 136 Micropipette single channel variable volume 100-1000 ul 137 Micropipette single channel variable volume 20-200 ul 138 Micropipette single channel variable volume 1-10 ul 139 Micropipette multichannel 120-1200 ul 140 Micropipette multichannel 30-300 ul 141 Bacterial DNA isolation kit for RTPCR 142 1x TBE Buffer 143 1x TAE Buffer 50 X Powder 144 DNA Ladder 1 KB 145 Loading Dye (6X) 146 Variable Volume single Channel Micropipette.2ul-20ul 147 Surecast TM TEMED and Sure Cast TM APD 148 Gel Staining Box 149 Eppendorf spectrophotometer Cuvette 150 Diamond Marker 151 Pasteur Pipettes (Sterile Individually Packed) 152 Temporary Marker Black 153 Temporary Marker Black 154 Thermometer 155 Neubauer’s Chamber 156 Hb Pipepete 157 WBC Pippete 158 RBC Pippete 159 Hb Tube 160 Thermal Paper Roll 55mm 161 Thermal Paper Roll 110mm 162 100-1000 ul Filter Tips with box 163 1-10 ul Filter Tips with box 164 1-20 ul Filter Tips with box 165 20-200 ul Filter Tips with box 166 Long Tips 1250ul with box 167 Single use Paper Towel 168 Nitrile Gloves-Medium 169 Nitrile Gloves-Large 170 PCR Tubes 171 20-200ul filter tips with box 172 Glass Bottle With Screw Cap (Borosilicate) 1000 ml 173 Glass Bottle With Screw Cap (Borosilicate) 500 ml 174 Glass Bottle With Screw Cap (Borosilicate) 100 ml 175 Graduated Microtips 300ul 176 Micro Tips 300ul 177 Glass Slide 75mm Long x 25 mm Widen 178 Oil Immersion (CDH) 179 Glacial Acetic Acid 180 Ferric Chloride 181 Sodium Chloride (Nacl) 182 Gram’s Iodine Powder 183 Potassium Iodide Powder 184 Potassium Iodide Powder 185 Basic Carbol Fuschin Powder 186 Phenol (Crystalline) 187 Methylene Blue Powder 188 Methyl Violet Powder 189 Albert Stain A 190 Albert Stain B 191 Laboline 192 Phenol 193 NALC 194 Ethanol 195 Ethanol Lab Grade 196 MPT 64 Antigens 197 Sodium Hypochlorite (5%) 198 Crystal Violet Powder 199 Iodine Powder 200 Safranine Powder 201 Refrigarator Minimum Gross Storage Capacity 260-300 Ltr. Model Type Double Door, Frost Free, Should be supplied with all standard accessories, One Year Warranty+05 Year Compressor Warranty Minimum 202 Refrigarator Minimum Gross Storage Capacity 320-350 Ltr. Model Type Double Door, Frost Free, Should be supplied with all standard accessories, One Year Warranty+05 Year Compressor Warranty Minimum
Contract Date: Mar 06, 2026 Contract Value : 20.00 Lakh
Government Departments No of Bidders 3
Madhya Pradesh View Result →
30.
Public Administrative Department #9347202 Technical Bid
Electrical Material Supply Year 2025-26 , Indoor Led Lamp Up To 9W , Led Street Light Fittingfor 26 To 26W , Led Street Light Fittingfor 40 To 55W , Led Flood Light Fittingfor 50 To 75W , Led Flood Light Fitting 75 To 90W , Led Flood Light Fittingfor 100 To 120W , Led Flood Light Fittingfor 120 To 150W , Ledlight Driverfor 26 To 50W , Ledlight Driverfor 50 To 75W , Ledlight Driverfor 75 To 100W , Ledlight Driverfor 100 To 120W , Ledlight Driverfor 120 To 150W , Surge Protection Device 10 Kv For Led Light , Square / Round Shaped Led Panel Light Suitable For 9 W - 12 W. , Led Panel Light Square / Round Shape Suitable For 19 To 24 W , Spmcb 6A To 32A , Spmcb 40A To 63A , Dpmcb 40A To 63A, , Spn Mcb 6A To 32A , Spn Mcb 40A , Tpmcb 16 A To 32A , Tpmcb 40A To 63A , Fpmcb16a To 32A , Fpmcb 40A To 63A , Four Pole Isolators Only Switch Version Of Miniature Circuit Breakers Of 40A , Four Pole Isolators Only Switch Version Of Miniature Circuit Breakers Of 63A , Spndb One Pole For Spmcb 1 No On Iron/ Gi Frame , Double Pole Isolator Only Switch Version Of Miniature Circuit Breaker Of 40A , Double Pole Metal Clad Switch 240V, 16A , Double Pole Metal Clad Switch 240V, 32A , Double Pole Metal Clad Switch 240V,63A , Triple Pole Metal Clad Switch 415V, 16A , Triple Pole Metal Clad Switch 415V, 32A , Triple Pole Metal Clad Switch 415V, 63A , Triple Pole Metal Clad Switch 415V, 100A , Triple Pole Metal Clad Rewireable Fuseswitch 415V, 200A , Wptc Alluminiumservicewire2 Core 4 Sq Mm , Wptcalluminium Servicewire2 Core 6 Sq Mm , Insulation Tape Roll , Wptcalluminium Servicewire2 Core 10 Sq Mm , Flat Flexible 3 Core 4 Sq Mm Pvc Sheathed Submersible Type Copper Cable , Flat Flexible 3 Core 6 Sq Mm Pvc Sheathed Submersible Type Copper Cable , Exhaust Fan Heavy Duty 230 V A.C. 50Cycles 300 Mm. 1400 Rpm , Wall Fan 400 Mm , Regular Ceiling Fan Of 1200 Mm. , Condenser 4 Mfd , Condenser 2.5 Micro Farad For Ceiling Fan , Pvc Casing-N-Capping Of Size 25 Mm , Pvc Casing-Ncappingof Size 32 Mm , Ceiling Rose / Batten Holder / 6A. , Lamp Holder 230 V.A.C. Supply. , Street Light Wall Bracket Made From 40 Mm. Dia , 1.5 Sq.Mm F.R Copper Wire , 2.5 Sq.Mm F.R Copper Wire , 4 Sq.Mm F.R Copper Wire , 6 Sq.Mm F.R Copper Wire , 7/20 Sq.Mm F.R Copper Wire , Fuse Wire 100 Amp , 2 Pole Contractor , 3 Polecontractor , Digital Time Switch , Analog Timer , Dwc Pipe 50 Mm Dia , Armoured Cable 2 Core 4Sq. Mm. Aluminium Conductor , Armoured Cable 2 Core 6Sq. Mm. Aluminium Conductor , Armoured Cable 2 Core 10Sq. Mm. Aluminium Conductor , Armoured Cable 2 Core 16Sq. Mm. Aluminium Conductor , Armoured Cable 4 Core 10Sq. Mm. Aluminium Conductor , Armoured Cable 4 Core 16Sq. Mm. Aluminium Conductor , Armoured Cable 3 ½Core 25Sq. Mm. Aluminium Conductor , Armoured Cable 3 ½Core 70Sq. Mm. Aluminium Conductor , Porcelainbase Cut Out415 V 16 A , Porcelainbase Cut Out415 V 32 A , Porcelainbase Cut Out415 V 63 A , Porcelainbase Cut Out415 V 100A , Single Phase Online Ups , 3 Phase Online Ups , 100Ahexit Talltubuler Battery , 120 Ahexittalll Tubuler Battery , 150Ahexittall Tubuler Battery , Single Phase 1 H P Submersible Openwellwater Pump , Single Phase 1 H P Submersible Water Pump For Borewell , 3 Phase 3 H P Submersible Water Pump For Borewell , 3Phase 5 H P Submersible Water Pump For Borewell , 3Phase 7.5 H P Submersible Water Pump For Borewell , 3Phase 3 H P Submersible Openwellwater Pump , 3Phase 5 H P Submersible Openwellwater Pump , 3Phase 7.5 H P Submersible Openwellwater Pump , Single Phase 1 H P Submersible Water Pump For Borewell , D. O. L. Starter Suitable For 250V. Single Phase, 50 Cycles With Connected To Supply Upto 3 H.P. , D.O.L. Starter 400V. 3 Phase, 50 Cycles With Connected To Supply Upto 7.5 H.P. , D.O.L. Starter 400V. 3 Phase, 50 Cycles With Connected To Supply For 7.5 Hp To 10 H.P. Relay Range 13-21 Amp , Screw Driver Set , Patti Pana Set , Ring Pana Set , Cutter , Noseplyer , Plyer , 32 Amain Switch , 63 Amain Switch , 100 Amain Switch , Flat Cable 3 Core 10 Sq Mm , Flat Cable 3 Core 16 Sq Mm , Street Light Bracket Single Arm , Flat Cable 3 Core 6 Sq Mm , Flat Cable 3 Core 4 Sq Mm , Led Pop Fitting 3 Watt , Led Pop Fitting 6 Watt , Led Pop Fitting 9 Watt , Led Pop Fitting 10 Watt , Led Pop Fitting 11 Watt , Led Pop Fitting 15 Watt , Led Pop Fitting 18 Watt , Led Pop Fitting 22 Watt , Led Pop Fitting 24 Watt , Led Bulb 2 Watt , Led Bulb 3 Watt , Led Bulb 5 Watt , Led Bulb 7 Watt , Led Bulb 9 Watt , Led Bulb 10 Watt , Led Bulb11 Watt , Led Bulb 13 Watt , Led Bulb 15 Watt , Led Bulb 18 Watt , Led Bulb 23 Watt , Led Bulb 27 Watt , Led Bulb 30 Watt , 6 Watt Led Consist Fitting , 28 Watt Led Consist Fitting , 250 Watt Led Focus , 200 Watt Led Focus , 100 Watt Led Focus , 50 Watt Led Focus , 30 Watt Led Focus , 36 Watt Led Street Light , 24 Watt Led Street Light , 50 Watt Led Street Light , 70 Watt Led Street Light , 100 Watt Led Street Light , L Type Pipe Fitting For Led Street Light Big , L Type Pipe Fitting For Led Street Light Small , Cfl Fitting 36 Watt , Cfl Fitting 26 Watt , Cfl Bulb 5 Watt , Cfl Bulb 9 Watt , Cfl Bulb 11 Watt , Cfl Bulb 15 Watt , Cfl Bulb 20 Watt , Cfl Bulb 25 Watt , Cfl Bulb 35 Watt , Cfl Bulb 45 Watt , Spot Light Cfl Rod 11 Watt , Street Light Cfl Fitting 45 Watt , Street Light Cfl Fitting 85 Watt , Cfl Focus Fitting 45 Watt , Cfl Focus Fitting 45 Watt , Cfl Focus Fitting 45 Watt , Cfl Spiral Bulb 100 Watt , Cfl Spiral Bulb 85 Watt , Cfl Spiral Bulb 25 Watt , Cfl Spiral Bulb 18 Watt , Cfl Spiral Bulb 13 Watt , Cfl Spiral Bulb 5 Watt , 40 Watt Bulb Bc , 40 Watt Bulb Bc , 40 Watt Bulb Bc , 40 Watt Bulb Bc , Night Frosted Coloured Bulb , Tube Rod 36 Watt , Tube Rod 40 Watt , Electronic Complite Tubelight , Electronic Tubelight Without Rod , Tube Light Holder Simple , Tube Light Holder Electronics , Choke Electronic Power Saver Blast 36 Watt , Alluminium Choke 36 Watt , Copper Choke 36 Watt , Bed Switch 1 Way , Bed Switch 2 Way , Indicator Switch 6 Amp , Switch 5 Amp , Switch 16 Amp , Switch 8 Amp , 6 Amp Modular Switch , 16 Amp Modular Switch , 32 Amp Modular Switch , 10 Amp Modular Switch , Main Switch 3 Pole /415 V. Tp 16 Amp , Main Switch 3 Pole /415 V. Tp 32 Amp , Main Switch 3 Pole /415 V. Tp 63 Amp , Main Switch 3 Pole /415 V. Tp 100 Amp , Power Plug 16 Amp Attached Switch & Socket , Main Switch 2 Pole / 240 V. Dp/16 Amp , Main Switch 2 Pole / 240 V. Dp/32 Amp , Surface Oneway Switch Black 16 Amp , Mcb 40 Amp , Mcb 16 Amp , Mcb 63 Amp , Mcb 25 Amp , Mcb 32 Amp , Mcb 20 Amp , Mcb 10 Amp , Mcb 6 Amp , Casing Patti 0.5 Inch , Casing Patti 0.75 Inch , Casing Patti 1 Inch , Casing Patti 1.5 Inch , Casing Patti 0.75 Inch , Casing Box 1 Way 1 , Casing Box 2 Way 1 , Casing Box 3 Way 1 , Casing Box 4 Way 1 , Casing Box 1 Way 2 , Casing Box 2 Way 2 , Casing Box 3 Way 2 , Casing Box 4 Way 2 , Casing Elbo 1 Inch , Casing Capping 1 Inch , Casing Joint 1 Inch , Casing T- 1 Inch , Casing Elbo 2 Inch , Casing Capping 2 Inch , Casing Joint 2 Inch , Casing T- 2 Inch , Casing Elbo 0.5 Inch , Casing Capping 0.5 Inch , Casing Joint 0.5 Inch , Casing T - 0.5 Inch , Casing Elbo 0.75 Inch , Casing Capping 0.75 Inch , Casing Joint 0.75 Inch , Casing T- 0.75 Inch , Casing Elbo 1.5 Inch , Casing Capping 1.5 Inch , Casing Joint 1.5 Inch , Casing T 1.5 Inch , Exhaust Fan 12 , Exhaust Fan 9 , Semi Exhaust Fan 15 , 2 Pin Top 6 Amp , 3 Pin Top 6 Amp , 3 Pin Top 16 Amp , Complete Power Plug 16 Amp With Fuse & Indicator , Socket 6 Amp , Socket 16 Amp , Surface 3 Pin Socket Black 6 Amp , Surface 3 Pin Socket Black 16 Amp , 6 Amp Modular Socket , 16 Amp Modular Socket , Socket & Top Male Female 6 Amp , Socket & Top Male Female 16 Amp , Industrial Top And Socket For A.C. , Pvc Gang Box 13 Way , Pvc Gang Box 14 Way , Mains Cord 3 Core , Ac Supply Cord For Cooler , Armord Cable 10 Mm 4 Core Isi Copper , Armord Cable 5 Mm 4 Core Isi Copper , Armord Cable 8 Mm 4 Core , Armord Cable 4 Mm 3 Core , Armord Cable 8 Mm 3 Core , Armord Cable 10 Mm 3 Core , Armord Cable 4 Core 70 Mm , Armord Cable 4 Core 50 Mm , Armord Cable 4 Core 35 Mm , Armord Cable 4 Core 25 Mm , Service Wire 4 Mm 2 Core Alluminium , Service Wire 10 Mm 2 Core Alluminium , Service Wire 2.5 Mm 2 Core Alluminium , Service Wire 6 Mm Multistud Copper , Service Wire 6 Mm 3 Corealuminium Wire , Pvc Copper Wire 0.75 Mm Isi Mark , Pvc Copper Wire 1.5 Mm Isi Mark , Pvc Copper Wire 1 Mm Isi Mark , Pvc Copper Wire 2.5 Mm Isi Mark , Pvc Copper Wire 4 Mm Isi Mark , Pvc Copper Wire 6 Mm Isi Mark , Pvc Copper Wire 8 Mm Isi Mark , Pvs Wire Copper 3/20 , Pvs Wire Copper 1/18 , Out Door Telephone Cable , Telephone Cable 2 Pair , Telephone Cable 5 Pair , Telephone Cable 10 Pair , Lan Cable T- 5 , Lan Cable T- 6 , R-G/6 Dish Cable , Door Bell Electronics , Ding Dong Bell , Codless Bell , De Spanner 10-11 , De Spanner 12-13 , De Spanner 14-15 , Adjustable Spanner , Screw Driver 6 , Combination Plier 8 , Screw Driver Set 8 , Tester , Nose Plier 6 , Wire Steeper , Heksaw Blade , Heksaw Frame , Ceiling Fan 32 , Table Fan , Ceiling Fan 24 , Pedalstand Fan Metel Body 1400 Amr , Pedalstand Fan Metel Body 1500 Amr , Pedalstand Fan Fibre Body 18 Amr , Pedalstand Fan Fibre Body 24 Amr , Pedalstand Fan Fibre Body 18 Amr , Wall Fan - 30 , Wall Fan - 24 , Wall Fan - 18 , Fan Regulator Electronics , Fan Regulator Std. , Cooler Motor 18 High Speed , Cooler Water Pump 5 Ft. High Speed , Cooler Regulator 650 Watt , Cooler Regulator 1000 Watt , Capacitor 4 Mfd , Capacitor 8 Mfd , Capacitor 10 Mfd , Capacitor 15 Mfd , Capacitor 20 Mfd , Capacitor 33 Mfd , Capacitor 42 Mfd , Kitkat Fuse Flush Wire 10 Amp , Kitkat Fuse Flush Wire 16 Amp , Fuse Wire 20 Amp , Fuse Wire 40 Amp , Fuse Wire 100 Amp , Invertor Fuse 45 Amp , Kitkat Grip 6 Amp , Kitkat Grip 16 Amp , Adaptor 9 Volt 0.5 Amp , Adaptor 12 Volt 0.5 Amp , Adaptor 5 Volt 0.5 Amp , Adaptor 9 Volt 1 Amp , Adaptor 12 Volt 1 Amp , Adaptor 5 Volt 1 Amp , Surface Mounting Box 1 Way , Surface Mounting Box 2 Way , Surface Mounting Box 3 Way , Isolator 40 Amp 3 Pole , Isolator 40 Amp 4 Pole , Isolator 100 Amp 3 Pole , Isolator 63 Amp 4 Pole , Pvc Elbo 1 , Pvc Bend 1 , Pvc Sandle 1 , Pvc T 1 , Pvc Pipe 1 , Pvc Dom With Base 6 , Pvc Dom With Base 8 , Pvc Dom With Base 12 , Pvc Dom With Base 18 , Garden Lamp Pvc Dom 6 , Garden Lamp Pvc Dom 8 , Modular Board 1 Way , Modular Board 2 Way , Modular Board 3 Way , Modular Board 4 Way , Modular Board 6 Way , Modular Board 8 Way , Modular Board 12 Way , Modular Board 18 Way , Modular Indicator , Modular Regulator , Pencil Cell 1.5 Volt Aa , Pencil Cell 1.5 Volt Rechargable , Pencil Cell 1.5 Volt Aaa , 6 Volt Dry Battery , 9 Volt Cell , 9 Volt Rechargable Cell , 12 Volt 150 Ahc Battery Tubelar , 12 Volt 88 Ahc Battery , 12 Volt 60 Ahc Battery , Search Light Bulb 12 Volt 55 Watt , 1.5 Volt/9 Volt Multy Purpose Charger , Change Over 3 Pole 415 Volt 16 Amp Isolater Type , Change Over 3 Pole 415 Volt 32 Amp Isolater Type , Change Over 3 Pole 415 Volt 63 Amp Isolater Type , Change Over 3 Pole 415 Volt 100 Amp Isolater Type , Telephone Spilter , Earthing Wire Copper 8 , Earthing Wire Copper 10 No , Earthing Wire Copper 12 No , Earthing Wire Copper 14 No , Earthing Wire Copper 24 No , Copper Plate For Earthing 10X10 , Copper Plate For Earthing 12X12 , Copper Plate For Earthing 12X15 , Earthing Powder , Sunmica Board 4X4 , Sunmica Board 6X8 , Sunmica Board 8X10 , Sunmica Board 10X12 , Roset For Telephone , Bell Push Swich , Ceiling Rose 6 Amp Jumbo 2 Plate , Ceiling Rose 6 Amp Jumbo 3 Plate , Pendent Holder , Change Over 4 Pole / 415 V/63 Amp Isolater Type , Change Over 2 Pole / Dp/16 Amp Isolater Type , Change Over 2 Pole / Dp/63 Amp Isolater Type , Torch Bulb 6 Watt , 15 Watt Thet Bulb , 36 Watt Pl Rod , 125 Watt Mercury Bulb , Sun Lamp Fitting 400 Watt , Siren 1 Mile , Siren 1/2 Mile , Starter Sheet , Insulation Tape , Wooden Gujja , Wooden Screw 12/4 , Wooden Screw 20/5 , Wooden Screw 60/8 , Wooden Screw 75/8 , Bross Nut Bolt 2 , Binding Wire 18 No , Soldering Wire , Trf 12-0-12 , Trf 18-0-18 , Cable Pin 0.75 Mm , Cable Pin 1 Mm , Cable Pin 2.5 Mm , Cable Pin 4 Mm , Cable Pin 6 Mm , Cable Pin 8 Mm , Cable Pin 10 Mm , Cable Pin 16 Mm , Cable Pin 25 Mm , Cable Pin 50 Mm , Cable Tie , Led 36 Watt Glass , 36 Watt Led Light Panel , Multimeter , 36 Watt Led Fitteng Driver , Timer 16 Amp (Street Light Box) Digital Crono Timer 67Ddtc , Contactor 40 Amp 4 Pole Mnx11 , Contactor 50 Amp 4 Pole Mnx12 , Contactor 63 Amp 4 Pole Mcx15 , Bracket Mouldinggi 1 .1/2 *5 Ft , Clamp Ms 25*3 18 , Nut Bolt Gi 3 , 4 Mm 3 Core Copper Flexible Wire , 1.5 Mm 3 Core Copper Flexible Wire , Mcb 63Amp 4 Pole , Mcb 40Amp 4 Pole , Mcb 40Amp 3 Pole , 6 Mm 3 Core Copper Flexible Wire
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 3
Maharashtra View Result →
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 4
Uttar Pradesh View Result →
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 2
Himachal Pradesh View Result →
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 5
Maharashtra View Result →
Contract Date: Jan 03, 2026 Contract Value : 14.45 Lakh
Government Departments No of Bidders 3
Maharashtra View Result →
36.
Public Administrative Department #8462115 AOC
Supply Of Machinery And Equipment For Various Laboratory - Tool. Presetter.,Materail .Handling Equipment.,Air .Compressor.,Bench.Grinder.,Dia.Indicator - 0.01Mm With Styallus (Needle Type).,Feeler .Gauge 0.05 To 1.0 Mm.,Radius.Gauge From 7.5 -15Mm.,Radius .Gauge Upto 7Mm.,Vernier .Bevel Protractor.,Universal .Magnetic Dial Stand.,Outside .Micrometre 25-50 Mm.,Outside .Micrometre 0-25 Mm.,Dial .Vernier 150 (0.02 Lc).,Digital .Vernier 0 - 150 Mm.,Vernier .Caliper 0 - 200 Mm.,Vernier .Caliper 0 -150 Mm.,Vernier .Height Gauge 300 Mm.,Center .Punch.,Scriberr.,Try .Square 4 Inch Blade.,Divider .Spring Type -150 Mm.,Inside .Caliper (Divider) 150.,Shell End Mill.Dia 63 X 70 X Bore Dia 27 Mm.,Consumables.Lidar, Depth Camera, Fpv Drone Kit.,Work.Bench.,Outside .Caliper (Divider) 150.,Machine. Brushes.,Bench .Brushes.,File .Brushes.,Hammer .Cross Peen 0.75 Kg With Handle.,Flat .Chisel.,Hss Hand .Hacksaw Blade 18 Tpi.,Parallel .Shank End Mill Dia 16 Double Fluted.,Parallel .Shank End Mill Dia 12.,Parallel .Shank End Mill Dia 10.,Parallel .Shank End Mill Dia 8.,Parallel .Shank End Mill Dia 6.,Slitting .Saw Cutter Dia 75 X 3 X Bore Size Dia 27 Mm.,Oil Stone. 25 X 52 X 150 Mm.,Hss Centre. Drill Dia. 8 Mm.,Hss Centre Drill Dia. 3.0 Mm.,Hss Counter Sink Bit. 120 Degree.,Hss Tap Set For Size .M4 - M12 With Wrench (Set).,Hss Drill Bit Straight .Shank Dia 3 To 12 Mm (Step Of 0.5 Mm) (Set).,Tool. Maker Mini Vice .235L X 88W X 88H (Jaw Opening 0-125).,Sine Bar .200 Mm.,Magnetic .V Block.,Machine Vice .150 Mm (Drilling).,Rotary .Table.,Dead .Centre.,Revolving .Centre.,Sleeves .Mt 3.,Sleeves .Mt 2.,Sleeves .Mt 1.,Self Centering Drillh Chuck 12 Mm.,Steel Almarahh.,Mechanical Work Benchess With Vice.,I9 Computerss.,Injection Moulding. Machine 100 Ton.,Ups-20Kvaa,Cctv - Set. Of 32 Camera.,Software-Master Cam (5 Userss).,Software - .Solid Works (60 Users).,Printerss.,Computerss.,Fly Presss.,Power Hacksaws.,Pedestal .Grinding Machine.,Pillar .Drilling Machine.,Cnc .Turning Machine.,Cnc .Milling Machine.,Cnc Simulatorss.,Science Lab (Sets).,Ar Application .Suite.,Augmented Reality Simulator Systems.,Relevant .Softwares.,Holograms. 50 Cm.,Holograms. 5Ft.,Autonomous Mobile Robot (Amr) .With Ai Navigation.,The Ai-Enabled .Quadruped Patrol Robot.,Collaborative Srobotic Arm.,Humanoid Robot Setup With Srequired Infra And Sensors.,Material Testing Machines Like Shardness Testers, Shear Tester, Torsion Tester, Bending Tester, Tension Tester, Compression Tester, Impact Tester.,Hybrid Solar Sustainable Energy Solutionss.,Wind Turbine Energy Generators Training Setups.,Solar Energy. Simulators.,Dual Axis Solar Tracking Systems.,Thermal Energy Training Systems.,Fuel Cell Training Syustems.,Solar Installation Training Setups.,Solar Ac Micro Grid Systems.,Basic Renewable Energy .Training Setup.,Real Time Simulation And .Emulator Setup.,Trolley Tool Kit With Hand Toolss.,Hydraulic Engine Floor Scrane.,Electric Vehicle Kits Chassis.,Hvac Demonstration Kits Of Ev.,Bldc Motor Kits.,New Energy .Battery Pack Training Bench (Simulator).,Cut Section .Bldc/Pmsm Motor 1000W 48-72V.,Battery Management. System Control Unit.,Ev 3 Wheeler. Training Setup.,Ev 4 Wheeler .Diagnostic Scan Tool Including Software.,Ev Lithium. Ion Battery Pack Training System.,Hybrid Vehicle .Transmission Unit.,Charging Station. Infrastructure.,Building Management System Trainer .With Hvac.,Fire Safety, Instruments & Public .Addressing System.,Sustainable Energy Conservation .System In Home.,See Software/Eplan.,Electrical Panel Engineering .With Smart Panel, Software And Current Injectors And Other Accessories.,Three Phase Electrical Control .Panel And Other Accessories.,Consumables Set Consists Of Electronics .Component.,Basic Electrical And Electronics Trainerr.,Earthing And Safety Demonstrator Kitt.,Intelligent Factory Integrated With .Scada And Iiot.,Three Phase Industrial Control Motorss.,Add On Motor Starter .Pack.,Power Cabinet And Plc. Instrumentation Pack.,Industrial Motor Drives Control .Pack.,Smart Integrated Plc Control System Trainerr.,Applications & Projectss.,Advance Hydraulic Trainerr.,Advance Pneumatic Trainerr.,Industrial. Sensors.,Thread Pitch Gauge Metric & Inches.,Surface Plate Granite 600 X 600 X 80 Mm With Stand.,Number Punch 5 Mm Set.,Ball Peen Hammer 250 Gms& 500 Gms.,Hacksaw Frame Fixed 300Mm.,Needle File Set.,Warding File Smooth 6.,Knife Edge File Smooth 6.,Knife Edge File Smooth 8.,Knife Edge File Second Cut 6.,Knife Edge File Second Cut 8.,Knife Edge File Second Cut 10.,Half Round File Smooth 6.,Half Round File Smooth 10.,Half Round File Second Cut 6.,Half Round File Second Cut 10.,Half Round File Second Cut 12.,Electrical Installation .Training Setup.,Safety Demonstrator With Safety .Kit Of 20 Sets.,Cpr Demonstratorr.,Consumables And Tools Sets.,Half Round File Bastard 12.,Round File Smooth 6.,Round File Smooth 10.,Round File Second Cut 6.,Round File Second Cut 8.,Round File Second Cut 10.,Round File Second Cut 12.,Round File Bastard 12.,Triangular File Smooth 6.,Triangular File Smooth 8.,Triangular File Second Cut 6.,Triangular File Second Cut 8.,Triangular File Second Cut 10.,Triangular File Bastard 10.,Square File Smooth 6.,Square File Smooth 8.,Square File Second Cut 6.,Square File Second Cut 8.,Square File Second Cut 10.,Square File Bastard 12.,Hand File Second Cut File 10.,Flat File Rough 12.,Flat File Smooth 8.,Flat File Smooth 10.,Flat File Second Cut 8.,Flat File Second Cut 10.,Flat File Second Cut 12.,Flat File Bastard.12.,Knurling Tool Straight & Diamond Cut.,Hss Tool. Bit 1/4. X 1/4 X 6.,Hss Machine Reamer Dia 6 - 10 Mm.,Hss Hand Reamer Dia 6 - 10 Mm.,Hss Die M4 - M12 With Die Stock.,Goose Neck Clamp Set.,Strap Clamp Set.,Clamp C. 10.,Clamp C. 5.,Tool Makers .Clamp 2.X 5.,General Consumables For Centre.,Lab Infra( Tables, Ambience Creation And Electrical Points Creation).,Two Tier Bunker.Cot In Nos.,Drawing Board With.Stand In Nos.,Duel Desk.In Nos.,Welding Machinery & Equipment.,Led Projector.,Inch 75 Interactive Boards With Stand And Ops,Printer 3D,Worldskills Mobile Robotics Kit,Hpc Server,Development Boards & Consumables Pack,Adas System,Smart Agriculture Assistant System,Smart Intelligent Robotic Arm,Smart Health Prediction System,Smart Front Desk Assistance,Smart Shopping Trolley,Smart Door Cam,Personal Voice Assistance,Smart Displays,High-Performance Pcs,Ar Devices,Ar/ Vr Spported Desktop Pcs I5, Ssd 500 Gb, 16Gb Ram,4 Gb Graphic Card, Preloaded Windows 11, Antivirus, Office Softwares,Assorted Displays,Ar Core Supported Devices,Vr Headsets,Vr Application Suite,Cloud-Based Ai Platform For Ar/Vr,Vr Headset.,Digital Factory With The Industry 4.0.,Kinematics Models Of All Types Of Drive System, Gears, Belts, Chain And Timing Belts.,Ev Lab Accessories Setup.,Wheeler 4 Ev Lighting And Wiring System With Vehicle Simulator.,Wheeler 4 Ev Battery Cooling System.,Wheeler 2 Ev Dc Motor Bldc/Pms Motor Trainer With Lithium Battery Motor Control Unit And Softwares.,Wheeler 2 Electric Training Setup With Charger.,Wheeler 4 Battery Electric Vehicle Setup.,Smart Survellivence& Access Control System.,Industrail Robot System With 4Kg Payload, Reach 800Mm And Auxiliary Control Setup And Vision Inspection System.,Smart Motor Soft Control Pack .,Iiot Hardware And Software Pack.,Mobile Robotics Training Pack With Worldskills Equipments And Consumables Set.,Training Bench For Hmi And Plc With Sensor Module.,Consumabless.,Iot Cloud .Platform.,Iot Feedback .System.,Iot Indoor. Gateway.,Iot Outdoor Gateway.,Iot Training Kit Using Multi Controller,Iot Training Kit Using Controller,Iot Workbench,Lorawan Traffic Light With Air Pollution Monitoring,Lorawan Energy Efficient Street Light,Iot Enabled Weather Monitoring System,Iot Based Attendance System,Waste Management System,Water Quality Monitoring System,Smart Agriculture Monitoring With Green House & Hydroponic System,Vehicle Tracking System With Gps,Iot Healthcare Kit,Iot Home Automation Kit,Power Electronics Work Bench With Consumables, Accessories And Required Infra,Op-Amp Trainer Pack Along With Consumables,Pcb Design Software,Pcb Prototyping Machine,Microcontroller Training Setup With Industrial Applications And Consumables,Diessectable Motor Trainer Setup,Transformer Training System,Machine Training System,Digital Electronics .Pack.,Analog Electronics Pack With The Consumables
Contract Date: Ref. Documents Contract Value : 89.29 Crore
Government Departments No of Bidders 1
37.
Rural Development #8100728 AOC
The new pipeline interconnection at West Sreenagar area near Kanu tea shop Ward No 21for betterment of water supply, under North Dum Dum Municipality..- 1 Cutting & picking up existing metalled black top portion of road surface to an average depth of 300 mm. by using jack hammer with all necessary tool and plant including screening the serviceable materials & stacking within a lead of 75mtr. all complete as per direction of the E.I.C 2 Labour for taking out old soling including removing debris to flank or berm, sorting out etc. a) Single Flat Soling 3 Hire charges of moveable type mounted earth excavator having minimum cutter size (1.0m3) & loader size (2.0 m length x 0.75 m width) for cutting & removal of any kind of soil,spoli etc including cost of fuel,lubricants & manpower etc. in water supply works.For beyond 8hrs of working 4 All types of CI specials (viz. Bend, Tee, Taper, Tail piece, Collar etc. size conforming to IS specification 1538:1993 a) socket & spigot endi) 80mm to 300mm 5 Manufacturing and supplying M.S. saddle with 10 mm. thick M.S. Pipe, 25 mm. thick M.S. Flange including fabrication true to size with M.S. Clamp, drilling hole on angle /flat, gas cutting and welding etc. 8 in / 6in 6 Wet connection with M.S. Saddle on running mains by drilling with electric drill, plugging with wooden plug using nut and bolts, rubber insertion, dewatering trenches all complete excluding cost of M.S. saddle & earth work. 8 in / 6 in 7 Shifting house connection or stand post connection from existing main to new main after excavation through any kind of soil and road materials up to required depth, dismantling existing ferrule with all fitings , pluggings hole of old main with GI plug drilling and tapping the new main, refixing the ferrule on the new main with serviceable old GI pipes and other specials and back filling the trench with excavated materials all complete as per specification and direction of the engineer-in-charge. 8 Supply, delivery and unloading and proper staking at site of multi jet class B domestic/commercial water metering system (size 15mm) strictly confirming to IS 779-1994 with all amendements or MID with AMR compatibility, cost for supply of water meter part B. 9 Earth work in excavation of foundation trenches or drains in all sorts of soil(including mixed soil but excluding laterite or sandstone) including removing spreading or stacking the spils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches. leveling,. dressing and ramming the bottom. bailing out water as required complete.a) Depth of excavation notexceeding1500mm. 10 Dewatering by pumps including all leads. lifts and making all arrangement of dispisal where continuous flow of water from a source other than natural or ground water is encountered in case of emergency maintenance works related to leakage. breakage and making wet connections.note:- In case of any other situation demanding such emergency dewatering use of this item is to be apporved by the Superintending Engineer/Tender Accepting Authority. This item shall be executed on the specific direction duly supported by proper clarification of the E.I.C 11 Supply of Ductile Iron K7 (DI) pipes confirming to IS:8329-2000 at project site including stacking, loading, unloading, labour, transportations etc complete 200 mm 12 150 mm 13 Lowering any type Ductile Iron pipes (DI) & specials and laying along trench at any depth as per specification and direction of the Engineer-in-charge.[For laying over ground. The rates shall be reduced by 10% and the rates so reduced shall be inclusive of cost of holding arrangements. 200 mm 14 150 mm 15 Supply and delivery of CIDF sluice valve (Special type) PW-1.00 of different dia make with CI double flanged non rusting spindle sluice valves conforming to IS 14846 -2000 with latestemended having body dome/bonnet and cover of C.I.Gr-F.G 210mtr. spindle of IS-6603 G.R-12/Gr-13 non-magnetic, nuts seat rings are of Gunonetal as per IS:318 LTB-2 flanges and drilled to IS:1538 Part IV & VI valves are suitable for max. working pressure of 10kg/cm2(seat test) and body tested to 15kg/cm2.N.B: The above item should be procured from the reputed manufactures as per deptt. approved vender list v) 200 mm dia. 16 Supplying including cost of installation of cast iron mechanical compressionflange socket tail piece for connecting flange fittings to the plain(spigot) ends of CI/DI pipes 200 mm 17 Supplying, fitting and fixing of C I Mechanical Compression flexible collar couplings suitable for inch size CI pipes and D I pipes confirming to class B of BS :1211 complete with sealing rubber gasket of EDPM quality IS :5382/1985 Type 4 Cast iron follower glands and mild steel nut bolts zinc coated, The whole assembly should be mechanically and hydraulically tested to the provisions as laid down in IS : 1538. Fitting and fixing should be in proper position with proper care of main pipe line for leak proof condition. 150 mm 18 Disinfection of water main by filling with water containing bleaching powder of sufficient quantity capable of maintaining a resudiual chlorine concentration of 10mg/1 within the main after a detention period of two hours and flushing the same with fresh water all complete as per specification and direction of the Engineer-in-Charge{After successful completiion of the process disposal of water and bacteriological testing of sample of flushed out water from the mains shall be made at no extra cost]150 mm 19 200 mm 20 Lowering, fitting and fixing of all types of valves in proper position and alignment using chain pully block or crane(for diameter above 250 mm.) by prividing temporary support, as reaquired gasket nuts & bolts etc all completeas per specification and direction of E.I.C200 mm 21 Inserting C.I.specials and Valves etc for interconnection with the exting wet main if any including excavation of trenches in any kind of soil& road torequired depth bailing out normal water from trenchs cutting the existing C.I pipes/Specials carefully and withdrawing the same including filling up the trench as per specification and instruction of the Engineer-in-charge of the work( valve;Collars,Specials lead joints lowering valves pipes shoring as when required will be paid seoerately as per schedule rate) 22 Lighting arrangement including temporary wiring and connecting to holder,bulbs etc hosting of generator set operator etc complete. 6.00PM to 5.00A.M 23 Hire charges of lighting generator of capacity 5KVA including fuel ,mobil,operator,carriage etc including all complete for water supply works. For minimum engagement of 8hrs in a day 24 Construction of different dia Sluice valvechamber in different sizes for village road where light traffic run and for main road where heavy traffic run as deptt.approved drawing with 25cm thick brick work (1:6) over cement concrete (4:2:1) over a single B/F soling over150mm.thick sand filling in foundation including earth work in excavation and disposal of excess earth from work site with RCC(1:1.5:3) cover slab 100mm / 150mm thick slab on top of chamber with 1% reinforcement in RCC cover slab with necessary opening for operation of valve all complete including cost of labour & materials as per Departmental Dwg. [Reinforcement type:- Other manufactuerers notspecified] i) 250 mm to 350 mm dia pipe 25 Brick soling with picked jhama bricks including preparation of bed as necessary, with brick joints properly filled in and packed with powdered earth and including necessary cushion of similar material below the soling (and in between layers when more than one layer is used) complete as per direction. Single brick flat soling(thickness 75 mm.) 26 OrdinaryCement concrete M15(mix4:2:1)withh graded stone chips (20mm down) excluding shuttering and reinforcement 27 Filling in fondation or plinth by silver sand in layers not exceeding 150mm as directed and consolidating same bythorough saturation with water raming complete including the cost of supply of sand ( pament to be made on measurement of finished quantity) 28 Earth work in filling in foundation trenches or plinth with good earth in layers not exceeding150 mm. including watering and raming etc. layer by layer complete. (Payment to be made on basis of measurement of finished quantity of work). 29 Sub Total 30 GST 18% 31 CESS 1%
Contract Date: Oct 13, 2025 Contract Value : 3.57 Lakh
Local Bodies No of Bidders 3
West Bengal View Result →
40.
Public Administrative Department #7859342 AOC
Municipal Council Wanadongri Invite E-Tender For Year 2025-2026 (12 Months) For Material Supply For Street Light Arrangement And Other Office Related Electrical Works.-02 LED POP FITTING 3 WATT 3 LED POP FITTING 6 WATT 4 LED POP FITTING 9 WATT 5 LED POP FITTING 10 WATT 6 LED POP FITTING 11 WATT 7 LED POP FITTING 15 WATT 8 LED POP FITTING 18 WATT 9 LED POP FITTING 22 WATT 10 LED POP FITTING 24 WATT 11 LED BULB 2 WATT 12 LED BULB 3 WATT 13 LED BULB 5 WATT 14 LED BULB 7 WATT 15 LED BULB 9 WATT 16 LED BULB 10 WATT 17 LED BULB 11 WATT 18 LED BULB 13 WATT 19 LED BULB 15 WATT 20 LED BULB 18 WATT 21 LED BULB 23 WATT 22 LED BULB 27 WATT 23 LED BULB 30 WATT 24 6 WATT LED CONSIST FITTING 25 28 WATT LED CONSIST FITTING 26 CFL FITTING 36 WATT 27 CFL FITTING 26 WATT 28 CFL BULB 5 WATT 29 CFL BULB 9 WATT 30 CFL BULB 11 WATT 31 CFL BULB 15 WATT 32 CFL BULB 20 WATT 33 CFL BULB 25 WATT 34 CFL BULB 35 WATT 35 CFL BULB 45 WATT 36 SPOT LIGHT CFL ROD 11 WATT 37 STREET LIGHT CFL FITTING 45 WATT 38 STREET LIGHT CFL FITTING 85 WATT 39 CFL FOCUS FITTING 18 WATT 40 CFL FOCUS FITTING 30 WATT 41 CFL FOCUS FITTING 45 WATT 42 CFL SPIRAL BULB 100 WATT 43 CFL SPIRAL BULB 85 WATT 44 CFL SPIRAL BULB 25 WATT 45 CFL SPIRAL BULB 18 WATT 46 CFL SPIRAL BULB 13 WATT 47 CFL SPIRAL BULB 5 WATT 48 40 WATT BULB BC 49 30 WATT BULB BC 50 20 WATT BULB BC 51 10 WATT BULB BC 52 NIGHT FROSTED COLOURED BULB 53 TUBE ROD 36 WATT 54 TUBE ROD 40 WATT 55 ELECTRONIC COMPLITE TUBELIGHT 56 ELECTRONIC TUBELIGHT WITHOUT ROD 57 TUBE LIGHT HOLDER SIMPLE 58 TUBE LIGHT HOLDER ELECTRONICS 59 CHOKE ELECTRONIC POWER SAVER BLAST 36 WATT 60 ALLUMINIUM CHOKE 36 WATT 61 COPPER CHOKE 36 WATT 62 BED SWITCH 1 WAY 63 BED SWITCH 2 WAY 64 INDICATOR SWITCH 6 AMP 65 SWITCH 5 AMP 66 SWITCH 16 AMP 67 SWITCH 8 AMP 68 6 AMP MODULAR SWITCH 69 16 AMP MODULAR SWITCH 70 32 AMP MODULAR SWITCH 71 10 AMP MODULAR SWITCH 72 MAIN SWITCH 3 POLE /415 V. TP 16 AMP 73 MAIN SWITCH 3 POLE /415 V. TP 32 AMP 74 MAIN SWITCH 3 POLE /415 V. TP 63 AMP 75 MAIN SWITCH 3 POLE /415 V. TP 100 AMP 76 POWER PLUG 16 AMP ATTACHED SWITCH & SOCKET 77 MAIN SWITCH 2 POLE / 240 V. DP/16 AMP 78 MAIN SWITCH 2 POLE / 240 V. DP/32 AMP 79 SURFACE ONEWAY SWITCH BLACK 16 AMP 80 MCB 40 AMP 81 MCB 16 AMP 82 MCB 63 AMP 83 MCB 25 AMP 84 MCB 32 AMP 85 MCB 20 AMP 86 MCB 10 AMP 87 MCB 6 AMP 88 CASING PATTI 0.5 INCH 89 CASING PATTI 0.75 INCH 90 CASING PATTI 1 INCH 91 CASING PATTI 1.5 INCH 92 CASING PATTI 0.75 INCH 93 CASING BOX 1 WAY 1 94 CASING BOX 2 WAY 1 95 CASING BOX 3 WAY 1 96 CASING BOX 4 WAY 1 97 CASING BOX 1 WAY 2 98 CASING BOX 2 WAY 2 99 CASING BOX 3 WAY 2 100 CASING BOX 4 WAY 2 101 CASING ELBO 1 INCH 102 CASING CAPPING 1 INCH 103 CASING JOINT 1 INCH 104 CASING T- 1 INCH 105 CASING ELBO 2 INCH 106 CASING CAPPING 2 INCH 107 CASING JOINT 2 INCH 108 CASING T- 2 INCH 109 CASING ELBO 0.5 INCH 110 CASING CAPPING 0.5 INCH 111 CASING JOINT 0.5 INCH 112 CASING T - 0.5 INCH 113 CASING ELBO 0.75 INCH 114 CASING CAPPING 0.75 INCH 115 CASING JOINT 0.75 INCH 116 CASING T- 0.75 INCH 117 CASING ELBO 1.5 INCH 118 CASING CAPPING 1.5 INCH 119 CASING JOINT 1.5 INCH 120 CASING T 1.5 INCH 121 EXHAUST FAN 12 122 EXHAUST FAN 9 123 SEMI EXHAUST FAN 15 124 2 PIN TOP 6 AMP 125 3 PIN TOP 6 AMP 126 3 PIN TOP 16 AMP 127 COMPLETE POWER PLUG 16 AMP WITH FUSE & INDICATOR 128 SOCKET 6 AMP 129 SOCKET 16 AMP 130 SURFACE 3 PIN SOCKET BLACK 6 AMP 131 SURFACE 3 PIN SOCKET BLACK 16 AMP 132 6 AMP MODULAR SOCKET 133 16 AMP MODULAR SOCKET 134 SOCKET & TOP MALE FEMALE 6 AMP 135 SOCKET & TOP MALE FEMALE 16 AMP 136 INDUSTRIAL TOP AND SOCKET FOR A.C. 137 PVC GANG BOX 13 WAY 138 PVC GANG BOX 14 WAY 139 MAINS CORD 3 CORE 140 AC SUPPLY CORD FOR COOLER 141 SERVICE WIRE 4 MM 2 CORE ALLUMINIUM 142 SERVICE WIRE 10 MM 2 CORE ALLUMINIUM 143 SERVICE WIRE 2.5 MM 2 CORE ALLUMINIUM 144 SERVICE WIRE 6 MM MULTISTUD COPPER 145 SERVICE WIRE 6 MM 3 CORE ALUMINIUM WIRE 146 PVC COPPER WIRE 0.75 MM ISI MARK 147 PVC COPPER WIRE 1.5 MM ISI MARK 148 PVC COPPER WIRE 1 MM ISI MARK 149 PVC COPPER WIRE 2.5 MM ISI MARK 150 PVC COPPER WIRE 4 MM ISI MARK 151 PVC COPPER WIRE 6 MM ISI MARK 152 PVC COPPER WIRE 8 MM ISI MARK 153 PVS WIRE COPPER 3/20 154 PVS WIRE COPPER 1/18 155 OUT DOOR TELEPHONE CABLE 156 TELEPHONE CABLE 2 PAIR 157 TELEPHONE CABLE 5 PAIR 158 TELEPHONE CABLE 10 PAIR 159 LAN CABLE T- 5 160 LAN CABLE T- 6 161 R-G/6 DISH CABLE 162 DOOR BELL ELECTRONICS 163 DING DONG BELL 164 CODLESS BELL 165 DE SPANNER 10-11 166 DE SPANNER 12-13 167 DE SPANNER 14-15 168 ADJUSTABLE SPANNER 169 SCREW DRIVER 6 170 COMBINATION PLIER 8 171 SCREW DRIVER SET 8 172 TESTER 173 NOSE PLIER 6 174 WIRE STEEPER 175 HEKSAW BLADE 176 HEKSAW FRAME 177 CEILING FAN 32 178 TABLE FAN 179 CEILING FAN 24 180 PEDALSTAND FAN METEL BODY 1400 AMR 181 PEDALSTAND FAN METEL BODY 1500 AMR 182 PEDALSTAND FAN FIBRE BODY 18 AMR 183 PEDALSTAND FAN FIBRE BODY 24 AMR 184 PEDALSTAND FAN FIBRE BODY 18 AMR 185 WALL FAN - 30 186 WALL FAN - 24 187 WALL FAN - 18 188 FAN REGULATOR ELECTRONICS 189 FAN REGULATOR STD 190 5 FEET DESERT COOLER ( WITH UNIVERSAL MOTOR, EXHAUST FAN, HIGH SPEED PUMP AND REGULATOR) 191 4 FEET DESERT COOLER ( WITH UNIVERSAL MOTOR, EXHAUST FAN, HIGH SPEED PUMP AND REGULATOR) 192 3 FEET DESERT COOLER ( WITH UNIVERSAL MOTOR, EXHAUST FAN, HIGH SPEED PUMP AND REGULATOR) 193 2 FEET DESERT COOLER ( WITH UNIVERSAL MOTOR, EXHAUST FAN, HIGH SPEED PUMP AND REGULATOR) 194 COOLER MOTOR 18 HIGH SPEED 195 COOLER WATER PUMP 5 FT. HIGH SPEED 196 COOLER REGULATOR 650 WATT 197 COOLER REGULATOR 1000 WATT 198 CAPACITOR 4 MFD 199 CAPACITOR 8 MFD 200 CAPACITOR 10 MFD 201 CAPACITOR 15 MFD 202 CAPACITOR 20 MFD 203 CAPACITOR 33 MFD 204 CAPACITOR 42 MFD 205 KITKAT FUSE FLUSH WIRE 10 AMP 206 KITKAT FUSE FLUSH WIRE 16 AMP 207 FUSE WIRE 20 AMP 208 FUSE WIRE 40 AMP 209 FUSE WIRE 100 AMP 210 INVERTOR FUSE 45 AMP 211 KITKAT GRIP 6 AMP 212 KITKAT GRIP 16 AMP 213 ADAPTOR 9 VOLT 0.5 AMP 214 ADAPTOR 12 VOLT 0.5 AMP 215 ADAPTOR 5 VOLT 0.5 AMP 216 ADAPTOR 9 VOLT 1 AMP 217 ADAPTOR 12 VOLT 1 AMP 218 ADAPTOR 5 VOLT 1 AMP 219 SURFACE MOUNTING BOX 1 WAY 220 SURFACE MOUNTING BOX 2 WAY 221 SURFACE MOUNTING BOX 3 WAY 222 ISOLATOR 40 AMP 3 POLE 223 ISOLATOR 40 AMP 4 POLE 224 ISOLATOR 100 AMP 3 POLE 225 ISOLATOR 63 AMP 4 POLE 226 PVC ELBO 1 227 PVC BEND 1 228 PVC SANDLE 1 229 PVC T 1 230 PVC PIPE 1 231 PVC DOM WITH BASE 6 232 PVC DOM WITH BASE 8 233 PVC DOM WITH BASE 12 234 PVC DOM WITH BASE 18 235 GARDEN LAMP PVC DOM 6 236 GARDEN LAMP PVC DOM 8 237 MODULAR BOARD 1 WAY 238 MODULAR BOARD 2 WAY 239 MODULAR BOARD 3 WAY 240 MODULAR BOARD 4 WAY 241 MODULAR BOARD 6 WAY 242 MODULAR BOARD 8 WAY 243 MODULAR BOARD 12 WAY 244 MODULAR BOARD 18 WAY 245 MODULAR INDICATOR 246 MODULAR REGULATOR 247 PENCIL CELL 1.5 VOLT AA 248 PENCIL CELL 1.5 VOLT RECHARGABLE 249 PENCIL CELL 1.5 VOLT AAA 250 6 VOLT DRY BATTERY 251 9 VOLT CELL 252 9 VOLT RECHARGABLE CELL 253 12 VOLT 150 AHC BATTERY TUBELAR 254 12 VOLT 88 AHC BATTERY 255 12 VOLT 60 AHC BATTERY 256 SEARCH LIGHT BULB 12 VOLT 55 WATT 257 1.5 VOLT/9 VOLT MULTY PURPOSE CHARGER 258 CHANGE OVER 3 POLE 415 VOLT 16 AMP ISOLATER TYPE 259 CHANGE OVER 3 POLE 415 VOLT 32 AMP ISOLATER TYPE 260 CHANGE OVER 3 POLE 415 VOLT 63 AMP ISOLATER TYPE 261 CHANGE OVER 3 POLE 415 VOLT 100 AMP ISOLATER TYPE 262 TELEPHONE SPILTER 263 EARTHING WIRE COPPER 8 264 EARTHING WIRE COPPER 10 NO 265 EARTHING WIRE COPPER 12 NO 266 EARTHING WIRE COPPER 14 NO 267 EARTHING WIRE COPPER 24 NO 268 COPPER PLATE FOR EARTHING 10X10 269 COPPER PLATE FOR EARTHING 12X12 270 COPPER PLATE FOR EARTHING 12X15 271 EARTHING POWDER 272 SUNMICA BOARD 4X4 273 SUNMICA BOARD 6X8 274 SUNMICA BOARD 8X10 275 SUNMICA BOARD 10X12 276 ROSET FOR TELEPHONE 277 BELL PUSH SWICH 278 CEILING ROSE 6 AMP JUMBO 2 PLATE 279 CEILING ROSE 6 AMP JUMBO 3 PLATE 280 PENDENT HOLDER 281 CHANGE OVER 4 POLE / 415 V/63 AMP ISOLATER TYPE 282 CHANGE OVER 2 POLE / DP/16 AMP ISOLATER TYPE 283 CHANGE OVER 2 POLE / DP/63 AMP ISOLATER TYPE 284 TORCH BULB 6 WATT 285 15 WATT THET BULB 286 36 WATT PL ROD 287 125 WATT MERCURY BULB 288 SUN LAMP FITTING 400 WATT 289 SIREN 1 MILE 290 SIREN 1/2 MILE 291 STARTER SHEET 292 INSULATION TAPE 293 WOODEN GUJJA 294 WOODEN SCREW 12/4 295 WOODEN SCREW 20/5 296 WOODEN SCREW 60/8 297 WOODEN SCREW 75/8 298 BROSS NUT BOLT 2 299 BINDING WIRE 18 NO 300 SOLDERING WIRE 301 TRF 12-0-12 302 TRF 18-0-18 303 CABLE PIN 0.75 MM 304 CABLE PIN 1 MM 305 CABLE PIN 2.5 MM 306 CABLE PIN 4 MM 307 CABLE PIN 6 MM 308 CABLE PIN 8 MM 309 CABLE PIN 10 MM 310 CABLE PIN 16 MM 311 CABLE PIN 25 MM 312 CABLE PIN 50 MM 313 CABLE TIE 314 LED 36 WATT GLASS 315 36 WATT LED LIGHT PANEL 316 MULTIMETER 317 36 WATT LED FITTENG DRIVER 318 TIMER 16 AMP (STREET LIGHT BOX) DIGITAL CRONO TIMER 67DDTC 319 CONTACTOR 40 AMP 4 POLE MNX11 320 CONTACTOR 50 AMP 4 POLE MNX12 321 CONTACTOR 63 AMP 4 POLE MCX15 322 BRACKET MOULDING GI 1 .1/2 * 5 FT 323 CLAMP MS 25*3 18 324 NUT BOLT GI 3 325 4 MM 3 CORE COPPER FLEXIBLE WIRE 326 1.5 MM 3 CORE COPPER FLEXIBLE WIRE 327 MCB 63AMP 4 POLE 328 MCB 40AMP 4 POLE 329 MCB 40AMP 3 POLE 330 6 MM 3 CORE COPPER FLEXIBLE WIRE 331 1-5’’ Ench x 1-5 feet Long GI Pipe Brackets Single Bend with Fabrication
Contract Date: Aug 25, 2025 Contract Value : 46,460
Local Bodies No of Bidders 3
Maharashtra View Result →
42.
Public Administrative Department #7631476 AOC
Supplying Amr Water Meter For Shirpur City
Contract Date: Jul 22, 2025 Contract Value : 14.61 Lakh
Local Bodies No of Bidders 1
Maharashtra View Result →
43.
Public Administrative Department #7479024 AOC
Supply Of Electrical Equipment From A Reputed Company For Daily Maintenance And Repair For The Financial Year 2025 To 2028. -1 Pop Screw ½ inch Nominated Company 2 Pop Screw 1 inch Nominated Company 3 Pop Screw 2 inch Nominated Company 4 GI Wire Nominated Company 5 Shoulder Gun SIRON/ DZK / INECO 6 Shoulder Wire SIRON/ DZK / INECO 7 Shoulder Gulu SIRON/ DZK / INECO 8 Drill Machine BOSCH 9 Grinder Machine BOSCH 10 Sound System Material Apple 2000 Watt AHUJA 11 Sound System Material Mike AHUJA 12 Sound System Material Horns 60WATTAHUJA 13 Sound System Material Speaker 60 WATTAHUJA 14 Sound System Material Codeless Mike Machine With AHUJA 15 Hammer TAPAR1A 16 Filter TAPAR1A 17 Multi Meter for A/C and DC Solar BOSCH 18 Silicone MCCOY 19 House Wiring Materials Casing Strip 1 Inch POLYCAB 20 Casing Comping Strip 2 Inch POLYCAB 21 Casing Comping Strip 4 Inch POLYCAB 22 Pipe 20mm POLYCAB 23 Pipe 16mm POLYCAB 24 Pipe 25mm POLYCAB 25 Pipe 75 x 8 Screw SUPER / KALOTI 26 Pipe 35 x 8 Screw SUPER / KALOTI 27 Plumbing Nails 1 Inch Nominated Company 28 Plumbing Nails 2 Inch Nominated Company 29 Plumbing Nails 3 Inch Nominated Company 30 Plumbing Nails 4 Inch Nominated Company 31 Rawal Plug 32 Flexible Pipe 16 mm Nominated Company 33 Fegiblepipe 20 mm named company 34 DWG Pipe 1 Inch Designated Company 35 DWG Pipe 2 inch Designated Company 36 DWG Pipe 3 inch Designated Company 37 DWG Pipe 4 inch Designated Company 38 6A SWITCH ROMA /ANCHOR 39 10A SWITCH ROMA /ANCHOR 40 3 Pin Socket 6A ROMA /ANCHOR 41 3 Pin Socket16A ROMA /ANCHOR 42 REGULATOR FAN 1 MODEL ROMA /ANCHOR 43 REGULATOR FAN 2 MODEL ROMA /ANCHOR 44 Fan Condenser (Condenser) 2.5 eqcos 45 Ceiling Rose POLYCAB 46 Screwware Box POLYCAB 47 Angle Holder POLYCAB 48 STRAIGHT HOLDER POLYCAB 49 junction box metal POLYCAB 50 Change-over - 16 A TANLE 51 Change-over - 32A TANLE 52 Change-over - 63 A TANLE 53 Change-over - 100 A TANLE 54 Change-over - 200 A TANLE 55 MAIN SWITCH 63 A- TANLE 56 MAIN SWITCH 100 A- TANLE 57 Main Switch 200 A- TANLE 58 Modul 1 Box -ROMA /ANCHOR 59 Modul 2 box ROMA /ANCHOR 60 Modul 3 Box ROMA /ANCHOR 61 Modul 4.6 Box ROMA /ANCHOR 62 Modul 8 Box ROMA /ANCHOR 63 Modul 18 Box ROMA /ANCHOR 64 Modul 24 Box ROMA /ANCHOR 65 Modular Switch Board ROMA /ANCHOR 66 POWER POINT 16A ROMA /ANCHOR 67 Modular MCB 20A Pole LT /ANCHOR 68 Modular MCB 22A Pole LT /ANCHOR 69 Modular MCB25A Pole LT /ANCHOR 70 Cable 300 Meter 1.mm Copper POLYCAB 71 Cable 300 Meter 2.5mm Copper POLYCAB 72 Cable 300 Meter 4.mm Copper POLYCAB 73 LIGHT FITTING JUNCTION 1ST POLYCAB 74 LIGHT FITTING JUNCTION 2ND POLYCAB 75 LIGHT FITTING JUNCTION 3RD POLYCAB 76 LIGHT FITTING JUNCTION 4TH POLYCAB 77 MCB REGULAR 1 POLE POLYCAB /LT 78 MCB REGULAR 10A POLE POLYCAB /LT 79 MCB REGULAR 20A POLE POLYCAB /LT 80 MCB REGULAR 25A POLE POLYCAB /LT 81 MCB Regular 40A POLE POLYCAB /LT 82 MCB REGULAR 2 POLE POLYCAB /LT 83 MCB REGULAR 1 POLE POLYCAB /LT 84 MCB REGULAR 10A POLE POLYCAB /LT 85 MCB REGULAR 20A POLE POLYCAB /LT 86 MCB REGULAR 25A POLE POLYCAB /LT 87 MCB REGULAR 40A POLE POLYCAB /LT 88 MCB REGULAR 4 POLE POLYCAB /LT 89 MCB REGULAR 32A POLE SCHNEIDER / LT 90 MCB REGULAR 40A POLE SCHNEIDER / LT 91 MCB REGULAR 63A POLE SCHNEIDER / LT 92 MCB REGULAR 100A POLE SCHNEIDER / LT 93 Focus (Focus Light) COB Garden Light 10 Watt CROMPTION / PHILIPS 94 Focus (Focus Light) COBGarden Light 6Watt CROMPTION /PHILIPS 95 Panel Round Light 10Watt CROMPTION /PHILIPS 96 Panel Round Light 14Watt CROMPTION /PHILIPS 97 Panel Round Light 18Watt CROMPTION /PHILIPS 98 Panel Round Light 20Watt CROMPTION /PHILIPS 99 Panel Round Light 25Watt CROMPTION /PHILIPS 100 Surface Light Panel and Round Light 06Watt CROMPTION /PHILIPS 101 Panel Round Light 10Watt CROMPTION /PHILIPS 102 Panel Round Light 14Watt CROMPTION /PHILIPS 103 Panel Round Light 18Watt CROMPTION /PHILIPS 104 Panel Round Light 20Watt CROMPTION /PHILIPS 105 PANEL ROUND LIGHT 25 WATT CROMPTION /PHILIPS 106 LED BULB 9 WATT CROMPTION /PHILIPS 107 LED Bulb 12 Watt CROMPTION /PHILIPS 108 LED Bulb 20 Watt CROMPTION /PHILIPS 109 LED Bulb 30 Watt CROMPTION /PHILIPS 110 LED BULB 9 WATT CROMPTION /PHILIPS 111 Simple Light 100W 112 A JOSE FAN250 mm ANCHOR 113 Inverter Battery 100AH ​​MICROTEK 114 Inverter Battery 200AH LUM INOUS 115 Inverter 1000KV Nominated Company 116 Inverter 700KV Nominated Company 117 Cello Tape Named Company 118 Com Tape Designated Company 119 Company Named Double Tape 120 Cordless Bell PRESSFIT 121 Drilling Machine Bit Set TAPAR1A 122 LNK Strip Pages Set TAPAR1A 123 Solar Battery Voltage 12.8,60wp, Wari , Havells 124 Solar Battery Voltage 60wp Wari , Havells 125 Solar Battery Voltage 24AH Wari , Havells 126 Stabilizer Stabilizers 4KW V Guard , MICROTEK 127 Stabilizer Stabilizers 5KW V Guard , MICROTEK 128 Stabilizer Stabilizers10KW V Guard , MICROTEK 129 Stabilizer Stabilizers20KW V Guard , MICROTEK 130 Stabilizer Stabilizers50KW V Guard , MICROTEK 131 Stabilizer Stabilizers100KW V Guard , MICROTEK 132 Stabilizer Stabilizers200KW V Guard , MICROTEK Nominated company for 133 LED light garland buildings 134 Iron 3 x 3 Panel Box (Iron) Nominated Company 135 11 KW Electrical Hand gloves Nominated Company 136 Gum Boots Nominated Company 137 25 AMR MCB Switch (LT / SCHNEIDER/ Havells) 138 Battery Water Distilled 139 813 Testers Tapuria 140 D.O. Rod 141 F.R. Box Clamp 142 1.5 (2 Core Copper Cabal) POLYCAB 143 CC MS Auto Panel 60 AMP ABB / Havells 144 CC MS Auto Panel 70 AMP ABB / Havells 145 CC MS Auto Panel 80 AMP ABB Havells 146 CC MS Auto Panel 100 AMP ABB / Havells 147 PV Solar Panel MC4 Connector Male & Female 148 4mm, Sq. mm DC cable make Red POLYCAB / Havells 149 4mm, Sq. mm DC cable make Black POLYCAB / Havells 150 6mm, Sq. mm DC cable make Red POLYCAB / Havells 151 6mm, Sq. mm DC cable make Black POLYCAB 152 Visit the store, Serplex Visit the store 5.0 out of 5 stars Serplex® Solar Crimper Tool Kit Wire Stripper Crimping Tool with Tool Bag, Pairs MC4 Connectors, Spanner Wrench for Solar Panel Cable Assembly 153 DC clamp meter solar for testing. 154 One-and-a-half-inch galvanized Pipe 155 Richard Box 01 to 14 Tool kit Tapuria 156 Richard Box 14 to 22 Tool kit Tapuria 157 BOSCH 11 RPMHAND Cutter Grinder 700-WATT BATTEY BOSCH 158 Wire Cutting Strip Taparia 159 Lug Clipping Tool 16mm to120 mm Ingco, Ingco 160 Solar Battery 12.8 Havells 161 Solar Battery 40w, Havells 162 Solar Battery 60W,P24AH Havells 163 Copper Wire 2 Core 2.5mm Flexible POLYCAB 164 Copper Wire 3 Core 2.5mm Flexible POLYCAB 165 Copper Wire 4 Core 2.5mm Flexible POLYCAB 166 Aluminum 16mm Armored Cable POLYCAB 167 Aluminum 35mm Armored Cable POLYCAB 168 Aluminum 75mm Armored Cable POLYCAB 169 Aluminum 120mm Armored Cable POLYCAB 170 2HP Motor Single Phase CROMPTION / Kirloskar 171 3 HP Motor 3 Phase CROMPTION / Kirloskar 172 2 HP Motor Single Phase Starter CROMPTION / Kirloskar 173 3 HP Motor 3 Phase Starter CROMPTION / Kirloskar 174 100 Watt LED Flood Light CROMPTION / PHILIPS 175 200 Watt LED Flood Light CROMPTION / PHILIPS 176 11KV Hand Gloves TECO kart / Serpley 177 11KV Safety Shoes Liberty / Stonix 178 Ceiling Fan CROMPTION / Bajaj 179 Wall Fans CROMPTION / Bajaj 180 Aluminum Lugs 16mm Nominated Company 181 Aluminum Lugs 35mm Nominated Company 182 Aluminum Lugs75mm Named Company 183 Aluminum Lugs120mm Designated Company 184 Aluminum Lugs240mm Named Company 185 ROPE LIGHT CROMPTION 186 ROPE LIGHT CONNECTOR CROMPTION 187 LED Strip Street Light 50 Watt PHILIPS 188 LED Strip Street Light 30 Watt PHILIPS 189 LED Choke Street Light 50 Watt CROMPTION/PHILIPS 190 LED Choke Street Light 30 Watt CROMPTION/PHILIPS 191 Asphalt Tape Designated Company 192 Flood Light Colors 20 WATT CROMPTION/PHILIPS Named Company 193 Flood Light colors 30 WATT CROMPTION/PHILIPS Named Company 194 Flood Light Colors 50 WATT CROMPTION/PHILIPS Named Company 195 Flood Light Colors 70 WATT CROMPTION/PHILIPS Named Company 196 Flood Light Colors 100 WATT CROMPTION / PHILIPS Named Company 197 Flood Light Colors 100 WATT CROMPTION / PHILIPS Named Company 198 DC/ Dimmer 30AMP Named Company 199 70WATT PHILIPS CHOKE OSARAM 200 75 WATTOSRAM Choke OSRAM 201 132 WATT ChokePHILIPS PHILIPS 202 25mm Socket Designated Company 203 25mm Bend Designated Company 204 25mm pipe named company 205 25mm T Designated Company 206 25mm bed named company 207 4 Inch Bit Designated Company 208 Fugitive Pipe Designation Company 209 Cutting Blade Nominated Company 210 Nut Bolt Nominated Company 211 400 mm Lug Nominated Company 212 Fegible Pipe Nominated Company 213 Bit Electrical Nominated Company 214 4 Inch Tapriya Belt Nominated Company 215 Cutting Drill Nominated Company 216 Rope Light Connector Nominated Company 217 Cable Tie Pocket Nominated Company 218 Pipe Nominated Company 219 Blade Cutting Nominated Company 220 Coupling Nominated Company 221 4 Inch Drill Bit Nominated Company 222 1/8 & 3/32 Screw Nominated Company 223 24 mm Screw Nominated Company 224 Cutting Blade Nominated Company
Contract Date: Jun 16, 2025 Contract Value : 1
Local Bodies No of Bidders 4
Maharashtra View Result →
44.
Drinking Water Supply and Sanitation #7152174 AOC
Supply, Installation, Testing And Commissioning ( Sitc ) Of Domestic Tamper Proof Water Meters Compatible To Existing Software As Per Standard Confirming To Is:779:1994 / Is:2373-1981 / Iso: 4064 / Oiml R 49 Or Eec / Mid Certification Mark Shall Be With Protection Class Of Ip68 For Amr Water Meter With 2 Years Warranty Of Installed Water Meter Including All Accessories As And When Required At Different Towns Anywhere In Uttarakhand-Rates Of Supply, Installation, Testing And Commissioning ( Sitc ) Of Domestic Tamper Proof Water Meters Compatible To Existing Software As Per Standard Confirming To Is:779:1994 / Is:2373-1981 / Iso: 4064 / Oiml R 49 Or Eec / Mid Certification Mark Shall Be With Protection Class Of Ip68 For Amr Water Meter With 2 Years Warranty Of Installed Water Meter Including All Accessories As And When Required At Different Towns Anywhere In Uttarakhand 2 Mechanical Type Amr Water Metersupply Of Dry Dial, Inferential Type, Multijet, Magnetically Coupled Class-B Tamper Proof Domestic Water Meters Plastic Cap Pre-Equipped For Remote Reading Complete With Tubular Strainer, Brass, Nuts And Nipples As Per Is:779:1994 / Iso: 4064 Standard Or Eec / Mid Certification Mark Shall Be With Protection Class Of Ip68 For Wireless Amr Water Meter With 2 Years Warranty Of Following Sizes. 15 Mm 3 Wireless Meter Reading Device With Display Facility ( For Walk By And Drive By ) - 1 Reader For Minimum 4000 Metering Points. 4 Installation, Testing And Commissioning Charges Of Dry Dial, Inferential Type, Multijet, Magnetically Coupled Class-B Tamper Proof Domestic Water Meterswater Meters With Plastic Cap, Removable Mechanism, Magnetic Drive, Hermetically Sealed, Pre-Equipped For Remote Reading Complete With Tubular Strainer, Brass, Nuts, As Per Is:779:1994 / Is:2373-1981 / So: 4064 Standard Or Eec / Mid Certification Mark Shall Be With Protection Class Of Ip68 And Nipples, Gi Pipe, Socket Stop Cock, Nrv Etc Material Required For Completion Of Work With Facility For Wireless Amr Water Meter With 2 Years Warranty With Strainer Anywhere In Uttarakhand Of Following Sizes.15 Mm 5 Providing, Supplying And Installation Of Pp Box To Accommodate Domestic Water Meter Of All Sizes Including Fixing Into Ground With Nails Or By Any Other Means Such As With Hinges Including Excavation Curing Etc Complete As Directed By Eic. 6 Repairing Work Such As Restoration Of Ramp, Steps Including Fixing Of Tiles Etc. With In The Premises Of Individual Households At The Time Of Installation Of Water Meter.
Contract Date: Mar 26, 2025 Contract Value : 10.00 Lakh
Government Departments No of Bidders 1
Uttarakhand View Result →
Contract Date: Ref. Documents Contract Value : 12.88 Lakh
Government Departments No of Bidders 4
Maharashtra View Result →
Contract Date: Ref. Documents Contract Value : 1.00 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 3
Jammu And Kashmir View Result →
Contract Date: Ref. Documents Contract Value : 9.58 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 12
Jammu And Kashmir View Result →
TenderDetail
Loading tenders