View Bid Results For Air Classification Equipment Tenders

We found 89 Bid Results related to air classification equipment tenders. You can find Contractor details who won air classification equipment tenders along with contract details in Bid awards announcements section.

Filters
Stage
53
31
5
Tender Publishing Platform
3
86
State / UT
19
20
18
11
6
5
5
4
4
3
2
2
2
1
1
1
1
1
1
1
Contract Value
39
7
26
17
Publish Date
0
0
0
0
0
Sector
13
18
17
17
10
9
7
4
2
1
1
1
1
1
Ownership
4
50
23
13
3
Within keyword
Active filters:
Showing 1–2 of 89 tenders matching your filters
1.
Housing Urban and Rular Development #11223252 Technical Bid
Tender for Supply Of 1 Loop Analogue Addressable Fire Alarm Control Panel Expandable Up To 4 Loop, Loop Current 500Ma Maximum Per Loop, Dual Flash Based Microprocessor, Supports To Connect 240 Addressable Devices One Each Loop Via Fully Digital Communication Protocol, Equipped With A White Backlit Display (240X64 Pixel Resolution) Graphical Lcd Display With At Least 6 Lines Of Information, 200 Fire Zones (Soft Zones), Fully Programmable Via Alphanumeric Keypad Or Configuration Software, Dedicated Usb And Rs-232 Serial Port For Direct Or Pc Connection. 5500 Events Storage, Loop Current 500 Ma, Panel Shall Be Equipped With In-Built Millimeter For Live Monitoring Of Loop Current, Earth Voltage, Loop Voltage Etc., Installers Logo Application, Can Be Networked To Compatible Addressable Panels And Repeater Panels By Adding A Network Card, Features Battery Charger Status And Temperature, Supports Programmable Cause / Effect On Outputs, Panel Housing Meets Ip30 Ingress Protection Classification. , Supply Of Intelligent Analogue Optical Smoke Detector With Advanced Optical Chamber And Smoke Inlet Design To Provide Resistance To Entry Of Dust To Provide Immunity To False Alarms, Programmable Multiple Smoke Sensitivity Level Setting, Bi-Directional In-Built Short Circuit Isolator To Protect Against Cable Faults, Dual Bi-Color Leds With 360O View Of Status, Auto-Addressable/Electronically Addressed, Utilizes Fully Digital Communication Addressable Protocol With High Noise Rejection. Approved By Lpcb For En 54-7 & En 54-17 Standard. , Supply Of Intelligent Analogue Class-P Heat Detector With Two Thermal Sensitivity Level, The Two Level Corresponds To Rate-Of-Rise (Ror) A1r Class (Most Sensitive) And Class Bs (Least Sensitive), Thermal Alarm Threshold For Ror A1r Class 58Oc And Bs Class 78Oc, Bi-Directional In-Built Short Circuit Isolator To Protect Against Cable Faults, Dual Bicolor Leds With 360O View Of Status, Auto Addressable/ Electronically Addressed, Utilizes Fully Digital Communication Addressable Protocol With High Noise Rejection. Approved By Lpcb For En 54-5 & En 54-17 Standard. , Supply Of Standard Detector Base For Mounting The Compatible Addressable Detectors. , Supply Of Intelligent Sounder Interface Module Allows Connecting Conventional Sounder Or Sounder Beacon To Addressable Loop, With In-Built Short Circuit Isolator, Allows For Two Stage Alarm Capability, Addressed Through Auto And Manual Options. Approved By Lpcb For En 54-17 & En 54-18 Standard. , Supply Of Conventional Wall Sounder With Beacon For Providing Audible And Visual Alarms In Response To The Output Signal From The Control Panel, 32 Selectable Tone And Adjustable Sound Level, Maximum Output Volume @ 1M Distance 100 Db(A), Output Tone Frequency Range 440 Hz To 2900 Hz, Visual Alarm Device Output Frequency 0.5 Hz, Approved By Lpcb For En 54-3 Standard. , Supply Of Intelligent Analogue Multi-Criteria (Combination Of Smoke And Heat) Detector With Special Algorithms To Utilize Information From Both Smoke And Heat Sensing Elements To Ensure High Level Of Immunity To False Alarms Without Compromising Genuine Alarm Sensing Performance, Programmable Multiple Smoke Sensitivity Level And 9 Modes Of Operation, Bi-Directional In-Built Short Circuit Isolator To Protect Against Cable Faults, Dual Bicolor Leds With 360O View Of Status, Auto Addressable/ Electronically Addressed, Utilizes Fully Digital Communication Addressable Protocol With High Noise Rejection. Approved By Lpcb For En 54-5, En 54-7, & En 54-17 Standard. , Supply Of Single Loop Driver Card Designed For Use With Compatible Analogue Addressable Panels, Provides Control And Connection/Communication To Maximum 240 Addressable Device Per Loop. , Supply Of Intelligent Analogue Manual Call Point With Resettable Operating Element, With In-Built Bidirectional Short Circuit Isolator. Bi-Color Led For Local Indication Of Device Status, Single Action Operation, Reset To Normal Condition Using Special Reset Key, Clearly Visible Alarm Flag In The Activated State. Approved By Lcpb For En 54-11 Standard. , Supply Of Mounting Accessories Like Back Box For Detectors, Devices & Cable Glands, Etc. , Supplying And Laying Of 2C X 1.5 Sq.Mm Pvc Insulated Copper Conductor Armoured Cable Encased Inside (By Providing And Laying) 1.5 Dia Pvc Insulated Conduit/Pipe Along With Fittings And Fixtures. Complete Job Includes Cost Of Material (Pvc Conduit, Cu Cable). Labour And Transportation. , providing and Fixing Of Wall Mounted Automatic Fire Extinguishers Abc Type Of Capacity 6 Kg Using Two Heat Sensing Quartzoid Bulb With Valves For Detection & Extinguishing Of Fires, Wall Mounted Automatic Fire Extinguisher Powder Based (As Per Is 4308) Automatic, Mild Steel, Hose Length 500 Millimeter, Quartzoid Bulbs Temperature Rating 68 Degree Celsius, Pressure Testing-Ped Certificate/ Ce Marking To Ped 2014/68/Eu, Annexure 3 (Module H) From Eu Notified Body. , providing and Fixing Of Stored Pressure Water Mist Based Fire Extinguishers 6 Liter Capacity. Bs En Standard Based Portable Fire Extinguishers, Conformity To Standard En 3-7 + A1: 2007 & En 3-8;2006 With Latest Amendment, Weight Of Filled Portable Fire Extinguisher (Kg) 10.438, Suitable For Class -A Fire Ratings As Per En 3-7 13A, Fire Rating For Class -F 75F,Operating Temperature (-30° C≤ N =60° C ), Warranty For The Complete Product 5 Year, Operating Temperature (+5° C To + 60° C), Service Pressure 15 Bar, Burst Pressure 112 Bar, Minimum Discharge Time (Seconds) Required As Per En Standard 12 Second, Shelf Life (Life Cycle) Of The Fire Extinguisher 10 Years, Marine Equipment Directive (Med) Approved Ce Certification From Eu Notified Body, Ce Identification Number Of The Notified Body (Must Declare),Ce 1128, Availability Of Test Report From Central Govt./Nabl/Ilac Accredited Lab To Prove Conformity To Specification Test Report No 1329B, Issue: 04, Test Report Date 20.07.2018 Name Of The Lab Bre Global Ltd. , providing and Fixing Water Mist & Caf High Pressure 50 Ltrs. Trolley (As Per En 1866-1:2007-08), Working Pressure 31 Bar, Air Bottle Capacity 6 Litre 300 Bar Pressure, Approved By Peso (Petroleum And Explosive Safety Organization),Fire Extinction - Suitability With Standard Afff 6% Confirming To Is 4989 Or Ul 162 Standards Class - A Fires, Class - B Fires, Class - B Polar Solvent Fires, Live Electrical Fires - 1000 V As Per En 3-7:2004+A1:2007 Tested For 35 Kv, Certification From Nabl Accredited Lab And Any Central Govt. Lab. (Tested In Indian Condition) As Per En 1866-1:2007-08. Test Report Shall Be Enclosed Along With The Offer, The Product Should Be Ped Certified To Ped 2014/68/Eu, Annexiii (Module H), The Supplier Should Have A License From Peso For Refilling & Storage Of High Pressure Gas Cylinders.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 4
Jammu And Kashmir View Result →
2.
Power #11110319 Technical Bid
Tender for Rate Contract For Procurement Of Material That May Be Required During The Emergencies For The Year 2026-27 In Respect Of Ed-3Rd , Supply Of , 50 Mm² Ab (Ht) Cable (3X50 + 1X70 Mm²) Xlpe(11 Kv, 3C + Earth) , 70 Mm² Ab (Ht) Cable (3 X 70 + 95 Mm²) Xlpe(11 Kv, 3C + Earth) , 120 Mm² Ab (Ht) Cable (3X120 + 1X95 Mm²) Xlpe(11 Kv, 3C + Earth) , 150 Mm² Ab (Ht) Cable (3X150 + 1X95 Mm²) Xlpe(11 Kv, 3C + Earth) , 185 Mm² Ab (Ht) Cable (3X185 + 1X95 Mm²) Xlpe(11 Kv, 3C + Earth) , 11 Kv Heat Shrinkable Outdoor Cable Termination Kit Upto 50- 95 Sqmm ( 3 Core) , Heat Shrinkable Outdoor Cable Termination Kit Above 120 To 185 Sqmm ( 3 Core) , Mid Span Straight Through Jointing Kit For 11 Kv Abc 120 -185 Sqmm , 35 Mm² Ab (Lt) Cable ( 3 X 35 + 1 X 16 + 1 X 25 Mm²(Insulated Messenger)) Xlpe (1.1Kv, 3+1 C, Al) , 50 Mm² Ab (Lt) Cable ( 3 X 50 + 1 X 16 + 1 X 35 Mm²(Insulated Messenger)) Xlpe (1.1Kv, 3+1 C, Al) , 70 Mm² Ab (Lt) Cable ( 3 X 70 + 1 X 16 + 1 X 50 Mm²(Insulated Messenger)) Xlpe (1.1Kv, 3+1 C, Al) , 95 Mm² Ab (Lt) Cable ( 3 X 95 + 1 X 16 + 1 X 70 Mm²(Insulated Messenger)) Xlpe (1.1Kv, 3+1 C, Al) , 120 Mm² Ab (Lt) Cable ( 3 X 120 + 1 X 16 + 1 X 70 Mm²) Xlpe (1.1Kv, 3+1 C, Al) , Mid Span Straight Through Jointing Kit For 1.1 Kv Abc 95-150 Sqmm , Mid Span Straight Through Jointing Kit For 1.1 Kv Abc 35-70 Sqmm , 70 Mm² Single-Core Cable, 1.1Kv Grade, Xlpe Un-Armoured Frls Type , 95Mm² Xlpe Lt Cable Single Core, Un-Armoured, Frls , 120 Mm² Xlpe Lt Cable Single Core, Un-Armoured, Frls , 150 Mm² Xlpe Lt Cable Single Core, Un-Armoured, Frls , 185 Mm² Cable, 1.1Kv Grade, Xlpe Un Armoured Frls Type , 240 Mm² Single Phase Cable,1.1K V Grade, Xlpe Un Armoured Frls Type , 300 Mm² Xlpe Lt Cable Single Core, Un-Armoured, Frls , 400 Mm² Single Phase Cable,1.1K V Grade, Xlpe Un Armoured Frls Type , 500 Mm² Xlpe Lt Cable Single Core, Un-Armoured, Frls , 630Mm² Xlpe Lt Cable Single Core, Un-Armoured, Frls , 10 Mm² Cable (2C), 1.1K V Grade, Armoured, Pvc Insulated Stranded Conductor Frls Type , 16 Mm² Cable (2C), 1.1K V Grade, Armoured, Pvc Insulated Stranded Conductor Frls Type , 10 Mm² Cable (4C), 1.1K V Grade, Armoured, Pvc Insulated Stranded Conductor Frls Type , 16 Mm² Cable (4C),1.1K V Grade, Armoured, Pvc Insulated Stranded Conductor Frls Type , 25 Mm² Xlpe Lt Cable 4 Core, Armoured, Frls , 35 Mm² Xlpe Lt Cable 4 Core, Armoured, Frls , Single Core 1 Mm² Cable Copper Wire , 1.1 Kv Grade, Isi, Frls. , Single Core 1.5 Mm² Cable Copper Wire , 1.1 Kv Grade, Isi, Frls. , Single Core 2.5 Mm² Cable Copper Wire , 1.1 Kv Grade, Isi, Frls. , Single Core 4 Mm² Cable Copper Wire , 1.1 Kv Grade, Isi, Frls. , Single Core 6 Mm² Cable Copper Wire , 1.1 Kv Grade, Isi, Frls. , 11 Kv, 3- Core Xlpe 35 Mm² Round Wire Armoured, Frls Cable , 11 Kv, 3- Core Xlpe 50 Mm² Round Wire Armoured, Frls Cable , 11 Kv, 3- Core Xlpe 70 Mm² Round Wire Armoured, Frls Cable , 11 Kv, 3- Core Xlpe 120 Mm² Round Wire Armoured, Frls Cable , 11 Kv, 3- Core Xlpe 150 Mm² Round Wire Armoured, Frls Cable , 11Kv, Three Core 185 Mm2 Aluminium Round Wire Armoured Xlpe Cable , Frls , 11 Kv, 3- Core Xlpe 240 Mm² Round Wire Armoured, Frls Cable , 11 Kv, 3- Core Xlpe 400 Mm² Round Wire Armoured, Frls Cable , 11 Kv End Termination For 3C 120- 185 Mm² , 11 Kv End Termination For 3C 240 To 400 Mm² , 11 Kv Straight Through Jointing Kit Upto 50-95 Mm² , 11 Kv Straight Through Jointing Kit Upto 120-185 Mm² , 11 Kv Straight Through Jointing Kit Upto 240-300 Mm² , 11 Kv Straight Through Jointing Kit Upto 400 Mm² , Lt Distribution Box For 25 Kva Dtr With 40 annual periodical maintenance Mccb 3P 16 Ka For Incomer & 25 annual periodical maintenance Mccb 3P 16 Ka/10 Ka 1 No. Each (=2No.) For Outgoing Circuits . , Lt Distribution Box For 63 Kva Dtr With 100 annual periodical maintenance Mccb 3P 16 Ka For Incomer & 100 annual periodical maintenance Mccb 3P 16 Ka 1 No. And 63 annual periodical maintenance Mccb 3P 16 Ka 1 No.S For Outgoing Circuits , Lt Distribution Box For 100 Kva Dtr With 160 Mccb 3P 16 Ka For Incomer & 100 annual periodical maintenance Mccb 3P 16 Ka 2 No.S For Outgoing Circuits , Lt Distribution Box For 200 Kva Dtr With 315 annual periodical maintenance Mccb 3P 25 Ka For Incomer & 160 annual periodical maintenance Mccb 3P 16 Ka 3 No.S For Outgoing Circuits , Lt Distribution Box For 250 Kva Dtr With 400 annual periodical maintenance Mccb 3P 36 Ka For Incomer & 200 annual periodical maintenance Mccb 3P 16 Ka 1 No. And 160 annual periodical maintenance Mccb 3P 16 Ka 2 No.S For Outgoing Circuits , Lt Distribution Box For 400 Kva Dtr With 630 annual periodical maintenance Mccb 3P 36 Ka For Incomer & 200 annual periodical maintenance Mccb 3P 16 Ka 4 No.S For Outgoing Circuits , Lt Distribution Box For 400 Kva Dtr With 630 annual periodical maintenance Mccb 3P 36 Ka For Incomer & 200 annual periodical maintenance Mccb 3P 16 Ka 4 No.S For Outgoing Circuits , Temporary Lt Fuse Set For Distribution Transformers (Customised) As Per Kpdcl Drawing No. Ce/P&P/Drg/2023/Ltfs/001 (Enclosed) , 11Kv Polymeric Composite Disc Insulator 12Kv,Min Failing Load 45Kn, Lighting Impulse 75Kv Positive And 80Kv Negative, Creepage Distance 320Mm Nos , 11Kv Polymeric Composite Pin Insulator 12Kv, 5Kn, Lighting Impulse 75Kv Positive And 80Kv Negative, Creepage Distance 320Mm , 16 Kn Polymer Shackle Insulator , G.I Mukey For Shackle Insulators With Bolt Of (50X8)Mm , Gi U-Clamps For Shackle Insulator 50X8 Mm, (3.14 Kg/Mtr), 258 Mm , Gi U-Clamps For Shackle Insulator 50X8 Mm, (3.14 Kg/Mtr), 369 Mm , 11 Kv Link Set Heavy Duty With Copper Blade Size Of 14 Inch, 50 X 6 Mm, Female Contact Of Copper 6 Mm Thickness, With Post Insulator Of 10 Kn , 11 Kv Go, Ab Switch 3-Phase, 3-Pole,200 Amp, Vertical Type Set , 11 Kv Horn Gap Fuse Set 3 Phase 200A Set , Pg Clamps For 30 Mm² Acsr Conductor , Pg Clamps For 50 Mm² Acsr Conductor , Pg Clamps For 100 Mm² Acsr Conductor , Suspension/Tension Clamp With Eye Hook , Gi Pole Support Clamp Including Gi Nut And Bolts For 11 Mtr Pole With Size - 50X8x376 Mm , Gi Pole Support Clamp Including Gi Nut And Bolts For 9 Mtr Pole With Size - 50X8x376 Mm , Gi Pole Support Clamp Including Gi Nut And Bolts For 8 Mtr With Size 50X 8X 328 Mm , Gi Pole Support Clamp Including Gi Nut And Bolts For 8 Mtr Or 9 Mtr Plain Cement Concrete With Size 50X8x441mm , Cable Tie (Each Packet Contains 100 Nos.) , Cable End Caps , Insulating Piercing Connectors Of Sizes , 11 Kv Ipc (Insulation Piercing Conductors)For Bare To Cc(Covered Conductor) Connection , 11 Kv Ipc For Covered Conductor To Covered Conductor Connection , 33 Kv Tension Clamps With Bail And Ipc (Insulation Piercing Conductors) , 33 Kv Ipc (Insulation Piercing Conductors)For Bare To Cc(Covered Conductor) Connection , 33 Kv Ipc For cement concrete To cement concrete Connection , 33 Kv Ipc With Aluminium Bail For Earthing , Main Single Phase Service Distribution Box (Pole Db) Along With Mccb /Mcb As Per Rec Drawing. The Db Should Have Bottom Entery Of Cable With Proper Glands/Grommets-Safety Screws And Back Clamp Suitable For 11/9/8 Mtr St Pole Or 9/8 Mtr Plain Cement Concrete Poles With Nuts/Bolts , Main 3 Phase Distribution Box Ip 54 (Pole Db) Made From 20 Swg Crca Ms Sheet By Deep Drawn Method With Powder Coating. Internal Size Of The Box Shall Be 225Mm X 285Mm X 120Mm Used For Connection Through Abc Line And For Giving Connections To The Consumers 3Phase-1 Incoming 4 Outgoing I/C- 1, O/G-2-4 (200 A, 0.415 Kv) For Ryb Phase. The Db Should Have Bottom Entery Of Cable With Proper Glands/Grommets-Safety Screws And Back Clamp Suitable For 11/9/8 Mtr St Pole Or 9/8 Mtr Plain Cement Concrete Poles With Nuts/Bolts , Lt Line Spacers 3 P ,4 Wire , Lt Line Spacers 2 P ,3 Wire , Gapless Surge Arrestor,9 Kv ,10 Ka ,La With Polymer Housing, Stn. Type , 3-Ø, 4-Wire Trivector Meter (Prodigy ) With Suitable Ring Type Ct 200 annual periodical maintenance (Net Meter Enabled) , Single Phase Smart Energy Meter 5-30 Amp/ 10-60 Amp, Dlms Complaint Of Accuracy Class 1.0 , Three Phase Smart Energy Meter 20-80 Amp/, Dlms Complaint Of Accuracy Class 1.0 , Polypropylene Weather Proof Outdoor Type Meter Box For Single Phase Meter Along With Zinc Plated Clamps , Polypropylene Weather Proof Outdoor Type Meter Box For Three Phase Meter Along With Zinc Plated Clamps , Polypropylene Weather Proof Outdoor Type Meter Box For 4 Single Phase Meter Along With Zinc Plated Clamps , Gi Barbed Wire For Anti Climbing , Danger Plates With Clamps , Anti-Climbing Device With Clamps , Cemical Earthing Complete , Earthing Mat (Gi Flat 50 Mm X8 Mm)/(75 X10)Mm/(75X8)Mm , Gi Pipe 40 Mm 3 Mtr Long For Earthing , Earthing Electrode ( 3M Long) 20 Mm Dia. , Gi Strip 25X3 Mm , Galvanized Earthing Strips 50Mm X3mm. , Red Oxide , Aluminium Paint , Galvanized Nuts And Bolts , Galvanised Stay Set With 50X8mm Stay Clamp, Guy Insulator(2No..), Anchor Plate (200X 200 X 6 Mm), Nut-Bolts, 2 No. Turn-Buckles, 1.8M Long, 16 Mm Diameter Solid Gs Stay Rod & 7/3.15 Mm Dia Gi Stranded Wire Complete (11 Kv) , Galvanised Stay Set With 50X8mm Stay Clamp, Guy Insulator(2Nos.), Anchor Plate (300X 300 X 8 Mm), Nut-Bolts, 2 Nos Turn-Buckles, 1.8M Long, 16 Mm Diameter Solid Gs Stay Rod & 7/3.15 Mm Dia Gi Stranded Wire Complete (33 Kv) , Gi V Cross-Arm With Top Bracket Of Sizes , Gi Channel X-Arm And Braces Of Sizes , Gi Extension Riser Of Sizes , Gi Wire 6 Swg & 8 Swg , Guard Netting (For 52 Mtr Span) , Aluminium Jointing Sleeves 100 Sqmm , Aluminium Jointing Sleeves 50 Sqmm , Aluminium Jointing Sleeves 30 Sqmm , Suspension Fitting (2 Bolt) For 11 Kv Line , Tension Fitting (4 Bolt) For 11 Kv Line , Suspension/Tension Clamp With Eye Hook , Earth Wire 7/4 Sqmm , 1 Phase 2 Wire, 415V, 1Nos Of 100 Amps Incoming Sp Mccbs Fitted With Outgoing 04 No 32 Amps Sp Mcbs For Service Connections, Distribution Service Pillar Suitable For Outdoor Installation, Made Out Of Crca Sheet Painted Through 7-Tank Process With Pu Painted Busbars 2P, Aluminium With Heat Shrinkable Sleeves And Adequate Capacities Complete With All Accesories 4 Way Distribution Service Pillar. , 3 Phase, 415V, 1No Of 250 Amps Incoming 3 Tp Mccbs (Breaking 36Ka) Fitted Withoutgoing 03 No 100 Amps Sp Mccbs, 1No.100Amps 3 Pole Mccb For Outgoing Lt Cables, Distribution Feeder Pillar Suitable For Outdoor Installation , Made Out Of Crca Sheet Painted Through 7-Tank Process With Pu Painted Busbars 4P, Aluminium With Heat Shrinkable Sleeves And Adequate Capacities Complete With All Accesories 4 Way Distribution Feeder Pillar. , Fire Extingiusher Co₂ Type Of 4.5 Kg Capacity For Control Room , 3 Sand Bucket Fire Extingiusher , Gum Boots With Steel Toe Of Sizes , Winter Jacket- Coat Ecc Consists Of Three Independent Components That Is Wind Cheater ( Waterproof ), Insulating Layer And Waist Coat ( Sleeve Less ), Three Layer Waterproof Breathable Fabric, Dual Shade Og/ White, Material Of Insulating Layer- 1. Batting Polyester, 100 Gsm, 2. Fabric Nylon Knitted Aluminized, 3. Fabric Nylon 75 Gsm White, Material Of Waist Coat- Double Layer Bonded Polyester Fleece , Safety Vest - Reflective Luminous Garments - High Visibility Warning Garments With Synthetic Slide Fasteners, Fluorescent Yellow, Width Of Retro Reflective Material For All Types Of Garments (Minimum) 50 Millimeter , Non-Contact Voltage Detector, Upon Detection, Tip Glows And Beeper Sounds, Cat Iv 1000 V For Added Protection, Expanded Range: 90 V To 1000 V Ac Or 200 V To 1000 V Ac, Battery Cell Operated (2 Aaa Or Standard), Voltbeat Technology And Continuous Self-Test , Safety Helmet- Quality Of Shell High Quality, High Impact, Light Weight,Tough, Conformity To Specification- Is 2925:Latest ,En 397 Certified , Safety Rubber Gloves Up To 15 Kv As Per Iec Standard , Safety Belt/Harness With Shock Absorber , Safety Shoes Of Sizes -Personal Protective Equipment - Safety Footwear As Per Bis Specification No Is 15298 ( Part 2 ): 2016, Toe Cap- ( Steel ) Metallic, Insole, Classification- Class I ( Footwear Made From Leather And Other Materials, Excluding All-Rubber Or All-Polymeric Footwear ) With Different Sizes, Slip Resistant- As Per Clause 5.3.5.4 Of Is 15298 ( Part 2 )- Slip Resistance On Ceramic Tile Floor With Nals And On Steel Floor With Glycerine. , 11 Kv Earthing/Discharging Rod (Set Of 3 Rods) Set With Minimum 20 Sqmm Cable And U-Clamp , Battery Operated 12 Kv Voltage Detector (Cpri Tested) Complete Kit Including Hv Detector Probe, 20 Feet Frp Insulation Stick, Carrying Bag. The Detector Should Have Audio As Well As Visual Anunciation, Sensing Distance Of 1 Meter For 11Kv. Bright High Intensity Red Leds For Visual Annunciation Even In Unfavourable Daylight Conditions And A Buzzer To Produce Loud Beep Audible Even In Noisy Backgrounds , Alumunium Ladder 2*20 (Double Ladder) 3 Mm Thick Anti Corossion, Anodised, Bottom Rubber, Sliding Type With Rope And Pulley Arrangement , Alumunium Ladder 2*15 (Double Ladder) 3 Mm Thick Anti Corossion, Anodised, Bottom Rubber, Sliding Type With Rope And Pulley Arrangement , Aluminium Ladder 2*10 Ft Long, Anti Corossion, Anodised, Bottom Rubber, Sliding Type With Rope , Bamboo Ladder 18 Ft Long, Natural Bamboo Finish, Min Load Bearing Capacity Of 150 Kg , Bamboo Ladder 20 Ft Long, Natural Bamboo Finish, Min Load Bearing Capacity Of 150 Kg , Wart Free Budloo Wooden Ladder 17 Feet Long And Slightly Tappered Upwards The Steps Are To Be Fixed With Flat Galvinized Iron Strip With Galvinized Nails. The Foot Of The Ladder To Be Provided With Rubber Anti Skid Hold. , Wart Free Budloo Wooden Ladder 20 Feet Long And Slightly Tappered Upwards The Steps Are To Be Fixed With Flat Galvinized Iron Strip With Galvinized Nails. The Foot Of The Ladder To Be Provided With Rubber Anti Skid Hold. , Telescopic Ladder 20 Ft Long, 6063 T5 Grade Of Aluminium , 150 Kg Load Capacity, Self Locking Mechanism, Anti-Skid Foot Caps , Hand Held Search Light Led Lamp, 100 Watt With Lithium Ion 3.7 V, 3.5 Ah, 500 Lux/100 Mtr With Lamp Life -50000 Hours, Ip 65, 12 Months Warranty , Hdpe Pipe Outer Dia 180 Mm Inner Dia 152 Mm For Laying Of 11Kv Xlpe Cable From Power Transformer To Control Room , Mccb - 200 Amps,36Ka,4P Adjustable , Mccb - 40 Amps,36Ka,4P Adjustable , Mccb - 63 Amps,36Ka,4P Adjustable , Mccb - 100 Amps,36Ka,4P Adjustable , Mccb - 160 Amps,36Ka,4P Adjustable , Mccb - 250 Amps,36Ka,4P Adjustable , Mccb - 400 Amps,36Ka,4P Adjustable , Mccb - 630 Amps,36Ka,4P Adjustable , Mccb - 200 Amps,36Ka,3P Adjustable , Mccb - 100 Amps,36Ka,3P Adjustable , Mccb - 160 Amps,36Ka,3P Adjustable , Mccb - 250 Amps,36Ka,3P Adjustable , Mccb - 400 Amps,36Ka,3P Adjustable , Mccb - 630 Amps,36Ka,3P Adjustable , Bobin Insulators Clamps/Cliffs. , Epoxy Resin Cast Panel Insulators Upto 500Mm , 18 Feet Fiber Link Rod , 18 Feet Bamboo Link Rod , Al. Solderless Clamps Suitable For Transformer 1000 Kva As Per Relevant Is , Al. Solderless Clamps Suitable For Transformer 630 Kva As Per Relevant Is , Al. Solderless Clamps Suitable For Transformer 400/500 Kva As Per Relevant Is , Al. Solderless Clamps Suitable For Transformer 250 Kva As Per Relevant Is , Al. Solderless Clamps Suitable For Transformer 100 Kva As Per Relevant Is , Al. Solderless Clamps Suitable For Transformer 63 Kva As Per Relevant Is , Aluminium Thimbles 630 Mm2 As Per Relevant Is , Aluminium Thimbles 500 Mm2 As Per Relevant Is , Aluminium Thimbles 400 Mm2 As Per Relevant Is , Aluminium Thimbles 300 Mm2 As Per Relevant Is , Aluminium Thimbles 240 Mm2 As Per Relevant Is , Aluminium Thimbles 185 Mm2 As Per Relevant Is , Aluminium Thimbles 120 Mm2 As Per Relevant Is , Aluminium Thimbles 95 Mm2 As Per Relevant Is , Aluminium Thimbles 70 Mm2 As Per Relevant Is , Aluminium Thimbles 50 Mm2 As Per Relevant Is , Aluminium Thimbles 35 Mm2 As Per Relevant Is , Aluminium Thimbles 25 Mm2 As Per Relevant Is , Aluminium Thimbles 16 Mm2 As Per Relevant Is , Aluminium Thimbles 10 Mm2 As Per Relevant Is , Dpc Copper Winding Wire (Round) In Sizes 11 To 22 Swg Fresh. , Dcp Copper Strip Of Sizes For Lv Winding Of Distribution Transformers 250 Kva To 630 Kva Fresh. , Se Copper Winding Wire (Round) In Sizes 11 To 22 Swg. , Dpc Aluminium Winding Wire (Round) In Sizes From 12 To 20 Swg-Fresh , Dpc Aluminium Strip Of Sizes For Lv Winding Of Distribution Transformers 25 Kva To 630 Kva - Fresh , Se Aluminium Winding Wire (Round) In Sizes 12 To 20 Swg-Fresh , Dpc Copper Winding Wire (Round) In Sizes 12 To 20 Swg ( In Exchange Of One Kg Of Scrap Of Salvaged Conductor) , Dpc Copper Strip Of Sizes For Lv Winding Of Distribution Transformers 25 Kva To 630 Kva( In Exchange Of One Kg Of Scrap Of Salvaged Conductor) , Se Copper Winding Wire (Round) In Sizes 11 To 22 Swg ( In Exchange Of One Kg Of Scrap Of Salvaged Conductor) , Dpc Aluminium Winding Wire (Round) In Sizes From 12 To 20 Swg ( In Exchange Of One Kg Of Scrap Of Salvaged Conductor) , Dpc Aluminium Strip Of Sizes For Lv Winding Of Distribution Transformers 25 Kva To 630 Kva ( In Exchange Of One Kg Of Scrap Of Salvaged Conductor) , Se Aluminium Winding Wire (Round) In Sizes 12 To 20 Swg ( In Exchange Of One Kg Of Scrap Of Salvaged Conductor) , Lv Brass Bush Rods 12 Mm , Lv Brass Bush Rods 19 Mm , Lv Brass Bush Rods 25 Mm , Lv Brass Bush Rods 32 Mm , Press Card Board Soft Calendared Solid 1Mm/2Mm/3Mm(As Per Sample) , Press Card Board Pre Compressed Solid 1Mm/2Mm/3Mm. , Ht Insulating Gum , Glass Wool Sleeves Of Sizes , Aluminium Brazing Rod (Standard Length) , Copper Brazing Rod (Standard Length) , Flexible Copper Strip (Shim) 75Mm X 0.5 Mm , Pvc Sheets 1 Mm Thick , Empire Tape 1 , Electrical Grade Kraft Paper, 4 Mil , Leatheroid Insulation Paper 20 Mil. , Hv Bushing , Lv Bushes Suitable For 63 To 100 Kva Dt , Lv Bushes Suitable For 200 To 250 Kva Dt , Lv Bushes Suitable For 400 To 630 Kva Dt , Epoxy Resin Cast 1.1 Kv Low Voltage Transformer Bushing With Busbar For 400/630 Kva Dt , Cotton Tape 1 (Size) 35 M Long. , Rubber Washers , Ht Paper , Cork Washer 12Mm Dia , Cork Washer20mm Dia , Cork Washer 25Mm/30Mm Dia , Plastic Metre Seals , Trifor (Tower Roller) , Transformer Oil Filitration Plant Filter Elements Of 1 Micron(60X250) Mm For Transformer Oil Filitration Plant , Heating Elements Of 2000 Watts For Transformer Oil Filtration Plant , Press Cardboard Cutter Having Bed=52X21 With Height Of Machine 45 With No. Of Tensile Springs 2 Nos. Complete In All Respects. , Angle Grinder, 800W Power, No-Load Speed Of 11000 Rpm, 100 Mm Disc , Welding Machine(Inverter Type) =5=10 Kva Rated Input Power, Maximum Welding Current At 60% Duty Cycle (In A) 150=250, Adjustable Hot Start,Anti-Stick Functions,Arc Force Control , Cordless Impact Drill/Drivers With 2 Batteries, Ideal For Driving Screws Into Wood And Drilling Into Masonry, Metal, And Wood , Pneumatic Air Impact Wrench With Sockets From 15 To 30 , Air Compressor 50 Ltr , Hand Held Brush Cutter , Hydraulic Crimping Tool , Pallet Truck 3 Ton , Hand Driven Insulation Resistance (Meggar) , Multimeter(Analog) , Multimeter(Digital) Voltage: Dc: 1000 Volts; Ac: 1000 Volts; Dc Accuracy: ± 0.5% + 3 Digit; Ac Accuracy: ± 1% + 3 Digit; Current: Dc: 10 Amps; Ac: 10 Amps; Dc Accuracy: ± 1.5% + 3 Digit; Ac Accuracy: ± 1.5% + 3 Digit; Resistance: 40 M Ohm; Resistance Accuracy: ± 1.5% + 3 Digit ; Capacitance: 1000 Μf; Capacitance Accuracy: ± 5% + 5 Digit Cat Iii 600 Volts Safety Rating , Pliers -Type Of Hand Tool-Combination Plier As Per Is 6149, Type Of Insulation-Rubber Insulation, Material-Carbon Steel , Nawara Tape 1 (Size) 35 M Long. , Rubberized Cork Sheet 4 Mm Thick 2Ftx3ft , Rubberized Cork Sheet 3Mm Thick 2Ftx3ft , Bakelite Tubes 12Mm Dia ( 1 Mtr Long) , Hv Bush Clamps (Ms) , Aluminium Clamping Member (Shoes) For Hv Bushing , Lv Cork Washers 12 Mm Dia , Lv Cork Washers 20Mm Dia , Lv Cork Washers 25 Mm/30 Mm Dia , Nuts & Bolts (M.S) Of Sizes. , M.S Flat Washers. , Hv Cork Washers 110 Mm O.D , Aluminium Welding Flux , Aluminium Flat 4/6/8/10 Mm Thick Of Required (Busbar) , Copper Flat 4/6/8/10 Mm Thick Of Required Width. (Busbar) , Ms Plug & Caps 1/2 ; 3/4; /1; 1.1/4; 1.1/2 , Oil Seal Rings (O-Rings) For Lv/Hv Bush Rods 12 Mm Dia. , Oil Seal Rings (O.Rings) For Lv/Hv Bush Rods 20 Mm Dia , Oil Seal Rings (O.Rings) For Lv/Hv Bush Rods 25 Mm Dia , Creep Tape 1 , Cotton Cloth , Empire Sleeves Of Sizes , Synthetic Enamel Paint Smoke Grey Colour , Paint Thinner , Steel Primer , Silica Gel , Transformer Oil As Per Is 335 And Amendments Thereof , Welding Rods 3.15 Mm/4Mm. (100 No. Per Packet) , Refilling Of Oxygen Gas For Brazing , Refilling Of Lpg Gas For Brazing , 12 Piece Tool Kit (1-Piece Screwdriver, 1-Piece Hammer, 7-Pieces Screwdriver Bits, 1-Piece Plier, 1-Piece Wrench(Adjustib And 1-Piece Measuring Tape) Bosch/Dewalt/Taparia , Clamp Meter, Conforms To Iec 61010, Cat Ii 600V Safety Rated, 600A Ac Current Measurement, Ac/Dc Voltage, Resistance, Continuity & Data Hold Function, 2 Years Manufacturer Warranty [Fluke/Digi Sense/ Motwane/Extech] , 12 Volts, 42 Ah Lead Acid Battery , 12V 7 Ah Rechargeable Sealed Maintenance Free Battery (Smf) For Ups , Battery Connector For 12 V Battery Bank (12 No. Both Ends Of Each Connector Should Be Properly Clamped With Nuts, Bolts, Washers) , Fabricated Gi Pollar Collar 50X6 Mm With Nuts And Bolts , Digital Weighing Scale Upto 1 Ton , Portable Professional Petrol Chainsaw,18 Inch Or Above, 2 Kw Or Above, Pitch Of 3/8 Or Above, Petrol Capacity 400 Ml Or Above. , Double Ply Polyester Webbing Slings, Load Capacity 6 Tonne , Dee Shackles Forged Shackles, Working Load 6.5 Tonne , Eyebolt With Recessed Collar With Maximum Axial Lifting Capacity Of 6 Tonne , Handheld Brush Cutter / Line Trimmer, With Nylon Feed Head Attachment Petrol Engine Low Vibration Centrifugal Clutch, Hardened Steel 2 Teeth Blade, Bump / Tap & Go Type, Shaft Length (Mm) 1425 To 1449, Circular Saw Attachment Inclusive In The Scope Of Supply , Portable Hydraulic Crimping Tool For 30 Sqmm To 400 Sqmm With All Attachments , Pre Fabricate Galvanized Single Way Top Bracket (1000 Mm Long With 48.3 Od Gi Pipe) To Be Fitted On Top Of Octogonal Pole For Holding Lighting Luminaries. , Dk Thermoplastic Cable Junction/ Termination T Boxes 8X10Of Class Ip55/Ip65 Fitted With Two 2-5 annual periodical maintenance Mcb Strip,4-Way Terminal Block / Connectors Incl. Copper Lugs, Clamps ,Nut & Bolts Washers Etc (Hansel Or Equivalent Make) Or Poles With Two Way Type Bracket To Be Fitted Properly Inside The Door Opened Gear Box Provided On Thebottom Side Of The Pole. , Surge Protector For The 120/190 Watt Led Type Lighting Fixture Complete. , Outdoor Type Lt Control Panel Size 900Mmx900mmx450mm Having Input Main Control Of 100 annual periodical maintenance Mccb With Tpn Bus Bar With 40 annual periodical maintenance Tpn Mcb 4Nos For Outgoing Circuits,Including Astronomical Switching With Contactor Of Required Capacity. The Panel Should Be Fitted With A Digital Composite Voltmeter/Ampermeter/Indicator Set With Selecter Switch And Backup Protection System, Thimbling And The Panel Shall Further Be Provided With Proper Openings On Front Side As Well As On Rear Side Including Its Locking Arrangement And Also With Required Glands And 4No. Angle Iron Legs For Grouting The Panel On Bed , The Panel Shall Also Be Provided With Powder Coat/Pu Paint. The Item Includes Its Thimble As Required At Taping Point For Incomming , Out Going And Internal Panel Wiring Complete Unit. , Dust/Rain/Snow-Proof Canopy Type Mini-Outdoor Lt Feeder Panel Of Size 450X300mm With Front Door Opening Duly Powdered Colour Coated With Inbuilt 2No Tpn 16-32 annual periodical maintenance Mccb,Tpn Busbars Of Same Capacity Installed On Cement Concrete Block With 4 Angle Iron Legs Grouted In The Cement Concrete Of Termination Of Main 25Sqmm Cable And Outgoing 25/16 Sqmm Cable Circuits. , 120 Watt Led Luminaries Of Ip 67 Protection. , 190 Watt Led Luminaries Of Ip 67 Protection. , 110 W Led Light Fitting With /= 100 Lm/Watt Efficacy Ip 67 Ingress Protection (Ip Rating) As Per Is:10322 (Part 1):1982 Latest, 90 To 300 Volts Ac At 50 Hz+/-2 Input Voltage Range, 230 V Ac 50 Hz Rated Voltage, Poly Carbonate Lense, Smd Led Chip As Per Lm 80/Is16106, Ip 66 Protection Of The Entire Housing (Both Led Section And Driver Section) As Per Is:10322 (Part 1):1982 Latest , 70W Led Light Fitting With /= 100 Lm/Watt Efficacy Ip 67 Ingress Protection (Ip Rating) As Per Is:10322 (Part 1):1982 Latest, 90 To 300 Volts Ac At 50 Hz+/-2 Input Voltage Range, 230 V Ac 50 Hz Rated Voltage, Poly Carbonate Lense, Smd Led Chip As Per Lm 80/Is16106, Ip 66 Protection Of The Entire Housing (Both Led Section And Driver Section) As Per Is:10322 (Part 1):1982 Latest , 50 W Led Light Fitting With /= 100 Lm/Watt Efficacy Ip 67 Ingress Protection (Ip Rating) As Per Is:10322 (Part 1):1982 Latest, 90 To 300 Volts Ac At 50 Hz+/-2 Input Voltage Range, 230 V Ac 50 Hz Rated Voltage, Poly Carbonate Lense, Smd Led Chip As Per Lm 80/Is16106, Ip 66 Protection Of The Entire Housing (Both Led Section And Driver Section) As Per Is:10322 (Part 1):1982 Latest , 30W Led Light Fitting With /= 100 Lm/Watt Efficacy Ip 67 Ingress Protection (Ip Rating) As Per Is:10322 (Part 1):1982 Latest, 90 To 300 Volts Ac At 50 Hz+/-2 Input Voltage Range, 230 V Ac 50 Hz Rated Voltage, Poly Carbonate Lense, Smd Led Chip As Per Lm 80/Is16106, Ip 66 Protection Of The Entire Housing (Both Led Section And Driver Section) As Per Is:10322 (Part 1):1982 Latest , 6 A Sp Mcb, 10 Ka Rated Short Circuit Capacity (Ampere), Instantaneous Tripping Range C, 1Pole With 1Pp, 240 V , 10 A Sp Mcb, 10 Ka Rated Short Circuit Capacity (Ampere), Instantaneous Tripping Range B, 1Pole With 1Pp, 240 V , 10 A Dp Mcb, 10 Ka Rated Short Circuit Capacity (Ampere), Instantaneous Tripping Range C, 2 Pole With 2 Pp, 240 V , 16 A Sp Mcb, 10 Ka Rated Short Circuit Capacity (Ampere), Instantaneous Tripping Range C, 1Pole With 1Pp, 240 V , 16 A Spn Mcb, 10 Ka Rated Short Circuit Capacity (Ampere), Instantaneous Tripping Range C, 2Pole With 1Pp, 415 V , 16 A Tp Mcb, 10 Ka Rated Short Circuit Capacity (Ampere), Instantaneous Tripping Range C, 3Pole With 3Pp, 415 V , 32 A Tpn Mcb, 10 Ka Rated Short Circuit Capacity (Ampere), Instantaneous Tripping Range C, 4 Pole With 3 Pp, 415 V , 32 A Tp Mcb, 10 Ka Rated Short Circuit Capacity (Ampere), Instantaneous Tripping Range C, 3 Pole With 3 Pp, 415 V , 32 A Dp Mcb, 10 Ka Rated Short Circuit Capacity (Ampere), Instantaneous Tripping Range C, 2 Pole With 2 Pp, 415 V , 32 A Sp Mcb, 10 Ka Rated Short Circuit Capacity (Ampere), Instantaneous Tripping Range B, 1 Pole With 1 Pp, 415 V , 63 A Tpn Mcb, 10 Ka Rated Short Circuit Capacity (Ampere), Instantaneous Tripping Range C, 4 Pole With 3 Pp, 415 V , Astronomical Timer For Street Light Control, 3 Phase, 18 Kw/43 A Each Phase, Ip 66, Manually Settable Timer With 12 Programmes Spreaded Over A Year As Defined Programme, 260 Volt +/- 5 Volt Over Voltage Protection Per Phase, 160 Volt +/- 5 Volt Under Voltage Protection Per Phase, Operating Temperature Range -10 To +50 Deg C, /=60 Seconds On/Off Timing Accuracy , Embossing Punch Die Tool For Dt Coding (A-Z And 0-9) , Battery Operated Engraving Machine , Hand Operated Oil Pump/Barrel Pump , Manilla Rope - 25 Mm , Nylon Rope- 20 Mm , 11Kv Pilfer Resistant Metering Cubicle For 3Phase 4 Wire Metering System Made Of Ms Sheet Steel Thickness Not Less Than 2Mm Duly Power Coat Painted Suitable For Indoor As Well As Outdoor As Per The Site Requirement. The Cubicle Shall Be Painted Through 7-Tank Process. The External Dimensions Should Be Adequate. Panel Having Two Compartments Upper Meter Compartment And Lower Ct/Pt Compartment. Provided With Synthetic Or Semi Synthetic Gasket Firmly Glued To The Sufrace, Dust, Weather And Vermin Proof And Shall Comply Degree Of Protection Ip 65 Both The Chambers Having One Sided Hinged Door Arrangments. The Metering Panel Shall Be Provided With Two No Ms Channels Of Size 100 X 50 Mm On The Front And Rear Sides Duly Welded And 4 No Of Lifting Hooks. It Should Be Possible To Take Meter Reading Manually, Through Cmri And Computer Without Opening The Lv Chamber Door. , Single Phase, Single Core, Single Ratio, Epoxy Resin Cast Current Transformers Suitable For 11Kv, Copper Wound Primary Type With Rated Burden 5Va And Accuracy Class 0.5 Or Better And Conforming To Is2705 (Part-I & Ii) Amended Upto Date. Isf Shall Be Upto 5The Ct Ratio Shall Be 2.5 /5 For 25Kva Dt , Single Phase, Single Core, Single Ratio, Epoxy Resin Cast Current Transformers Suitable For 11Kv, Copper Wound Primary Type With Rated Burden 5Va And Accuracy Class 0.5 Or Better And Conforming To Is2705 (Part-I & Ii) Amended Upto Date. Isf Shall Be Upto 5The Ct Ratio Shall Be 5/5 For 63Kva Dt , Single Phase, Single Core, Single Ratio, Epoxy Resin Cast Current Transformers Suitable For 11Kv, Copper Wound Primary Type With Rated Burden 5Va And Accuracy Class 0.5 Or Better And Conforming To Is2705 (Part-I & Ii) Amended Upto Date. Isf Shall Be Upto 5The Ct Ratio Shall Be 7.5/5 For 100Kva Dt , Single Phase, Single Core, Single Ratio, Epoxy Resin Cast Current Transformers Suitable For 11Kv, Copper Wound Primary Type With Rated Burden 5Va And Accuracy Class 0.5 Or Better And Conforming To Is2705 (Part-I & Ii) Amended Upto Date. Isf Shall Be Upto 5The Ct Ratio Shall Be 15/5 For 200Kva Dt , Single Phase, Single Core, Single Ratio, Epoxy Resin Cast Current Transformers Suitable For 11Kv, Copper Wound Primary Type With Rated Burden 5Va And Accuracy Class 0.5 Or Better And Conforming To Is2705 (Part-I & Ii) Amended Upto Date. Isf Shall Be Upto 5The Ct Ratio Shall Be 20/5 For 250Kva Dt , Single Phase, Single Core, Single Ratio, Epoxy Resin Cast Current Transformers Suitable For 11Kv, Copper Wound Primary Type With Rated Burden 5Va And Accuracy Class 0.5 Or Better And Conforming To Is2705 (Part-I & Ii) Amended Upto Date. Isf Shall Be Upto 5The Ct Ratio Shall Be 25/5 For 400 Kva Dt , Single Phase, Single Core, Single Ratio, Epoxy Resin Cast Current Transformers Suitable For 11Kv, Copper Wound Primary Type With Rated Burden 5Va And Accuracy Class 0.5 Or Better And Conforming To Is2705 (Part-I & Ii) Amended Upto Date. Isf Shall Be Upto 5The Ct Ratio Shall Be 50/5 For 630 Kva Dt , Single Phase, Single Core, Single Ratio, Epoxy Resin Cast Current Transformers Suitable For 11Kv, Copper Wound Primary Type With Rated Burden 5Va And Accuracy Class 0.5 Or Better And Conforming To Is2705 (Part-I & Ii) Amended Upto Date. Isf Shall Be Upto 5The Ct Ratio Shall Be 75/5 For 1 Mva Dt , 11Kv/ 110 V, Three Phase Epoxy Resin Cast Pt With Rated Burden 15Va Per Phase And Accuracy Class 0.5 Or Better And Conforming To Is:3156 (Part-I&Ii) Amended Upto Date With Proper Colour Coded Identification. Pts Shall Be Of Uniform Insulating And Withstand Separate Source 23Kv providing fixing For One Minute. , 3Ph, 3 Wire Ht Ct/Pt Operated Fully Static Smart Tri-Vector Energymeters Dlms Compliantcategory C With Rs232 Port For Modem Compatibility. 11Kv/110V, Ph-Ph (3P,3W) Metersfor Measurement Of Different Electrical Parameters Including Active Energy (Kwh/ Mwh), Reactive Energy (Kvarh/Mvarh), Apparent Energy (Kvah/ Mvah) Etc. (Make L&T, Secure,Abb) , Led String Light 15 Mtr Long Of Different Colours (Saffron/White/Green) With Controller. , 4 Socket Extension Boards With Each Compatible Sockets Of 16 annual periodical maintenance And 5 Mtr Long Cable And Plug Along Surge Protector And On/Off Controller.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 6
Jammu And Kashmir View Result →
3.
Educational and Research Institute #11098868 AOC
Tender For Iehe Bhopal Invites Online Tender For Supply Of Sound System In The Institute , Sound System , Wall Mount Cabinet Loudspeaker General Requirements: The Loudspeaker Shall Be A Cost-Effective, 12W General-Purpose Cabinet Speaker Designed For Indoor Surface-Mount Applications. It Must Be Suitable For Both High-Quality Speech Intelligibility And Background Music Reproduction Acoustic Performance: Rated Power: 12W, With Adjustable Power Tappings At 12W, 6W, And 3W To Allow For 3 Db Step Adjustments. Sound Pressure Level (Spl): Must Provide A Maximum Special Of 102.0 Db At 6W/1M (1 Khz) And A Sensitivity Of 91.7 Db At 1W/1M (1 Khz). Frequency Range: The Effective Frequency Range Shall Be From 150 Hz To 15 Khz. Opening Angles: Horizontal: 184° (1 Khz) / 86° (4 Khz). Vertical: 66° (1 Khz) / 58° (4 Khz). Electrical Specifications: Input Voltage: Designed For 100 V Line Systems. Rated Impedance: 833 Ohms. Connection: Shall Feature A 4-Pole Push-In Terminal Block On The Rear Panel For Easy On-Site Wiring And Power Tapping. Durability: The Unit Must Be Tested For 100 Hours Of Continuous Operation At Rated Power In Accordance With Iec 268-5 Standards. Mechanical Construction Enclosure Material: The Main Body Shall Be Constructed From Solid Mdf (Medium Density Fiberboard) Covered In Durable, Easy-To-Clean Black Vinyl. Front Grille: The Front Shall Be Abs Plastic Covered With A Fine Woven Cloth In Matching Black. Baffle Design: Shall Feature An Angled Front Baffle To Optimize Sound Distribution Within The Listening Area. Mounting: The Rear Panel Must Include Three Keyholes For Quick And Secure Wall Mounting. Dimensions: 445 Mm X 151 Mm X 150 Mm / 111 Mm Environmental Limits: Operating Temperature: -5 °C To +55 °C, Storage Temperature: -40 °C To +70 °C , Wireless Microphone System General System Requirements: Classification: The System Shall Be An Entry-Level Professional Wireless Microphone System Designed For Ruggedness And Ease Of Use In Daily Operations. Ease Of Setup: The System Must Include A One-Button Automatic Frequency Scanning Function To Identify The Clearest Available Channel. Transmitter Synchronization Shall Be Achieved Via An Infrared Data Link To Ensure Error-Free Setup. Frequency Management: The System Shall Provide 32 Preset Channels, With Compatible Groups Of Eight Channels For Simultaneous Multi-Channel Use. Operating Bands: The System Shall Be Available In Multiple Rf Frequency Bands, Including: A Band: 618-634 Mhz. B Band: 678-694 Mhz. C Band: 516-532 Mhz. E Band: 850-865 Mhz. Receiver Specifications Type: Synthesized Pll With True Antenna Diversity To Ensure Stable Rf Reception. Chassis: The Receiver Must Feature A True Rack-Mountable Metal Chassis Suitable For Professional Installation. Rf Performance: Sensitivity: 1.0 Μv For 12 Db Sinad. Image Rejection: Greater Than 55 Db. Audio Outputs: Balanced Output: 20 Dbv (Max @ 40 Khz Deviation). Unbalanced Output: Adjustable From 8 Mv To 0.755V Rms. Display: Front-Panel Backlit Lcd Displaying Channel, Frequency, And Battery Status. Handheld Transmitter Construction: The Transmitter Shall Feature A Rugged Metal Body Designed To Withstand The Rigors Of Daily Use. Microphone Capsule: Equipped With A Cardioid Dynamic Capsule (Pl22) For Effective Feedback Control And Ambient Noise Rejection. Battery Life: Must Operate For A Minimum Of 14 Hours Using Two Aa Alkaline Batteries. User Interface: Features A Backlit Lcd Display And A Dedicated Mute Function To Protect The Audio Channel. Bodypack Transmitter Construction: Compact And Rugged Metal Enclosure. Input Connector: Industry-Standard Ta4F Connector For Compatibility With Various Lapel Or Headworn Microphones. Antenna: Flexible External 1/4 Wave Antenna. Acoustic & Environmental Performance System Frequency Response: 80 Hz - 18 Khz ± 2 Db Signal-To-Noise Ratio: 100 Db A-Weighted Total Harmonic Distortion: 1.0%, 0.4% Typical (Ref 1 Khz, 40 Khz Deviation) , Professional Gooseneck Microphone General Requirements: The Microphone Shall Be A Professional-Grade, High-Quality Electret Condenser Gooseneck Microphone Designed For Public Address Applications Such As Lecterns, Podiums, And Open Conferences. It Must Feature A Sleek, Slender, And Unobtrusive Design To Maintain A Clear Line Of Sight For The User. Acoustic & Technical Performance Transducer Type: Electret Condenser. Polar Pattern: Unidirectional (Cardioid) To Ensure High Front-To-Back Rejection, Providing More Gain Before Feedback. Frequency Response: Wide Range From 20 Hz To 18,000 Hz. Sensitivity: 7.5Mv/Pa Power Requirement: Operable Via A Dc Power Source Ranging From 1.5V To 9V. Mechanical Specifications Overall Length: 585 Mm (Approximately 23 Inches) Output Connector: Built-In 3-Pin Xlr Male Socket For Secure And Standard Professional Connectivity. Optional Accessories (Compatibility) To Ensure System Flexibility, The Microphone Must Be Compatible With The Following Manufacturer-Specific Accessories: Microphone Base: A Sturdy, Heavy-Duty Die-Cast Aluminium Base With An Integrated On/Off Switch, Led Indicator, And Built-In Housing For 2 Times 1.5V Um-3 Aa Cells To Power The Condenser Element. Mic Stand Adaptor: A Rugged Aluminium Die-Cast Body With A Female Xlr Connector For Direct Mounting And A Male Xlr Bottom Connector For Cable Attachment. It Must Include A 10-Meter Shielded Cable And A Threaded Brass Ferrule 5/8 27 Tpi For Standard Stand Mounting. , Mixer Amplifier General System Requirements Type: The Unit Shall Be A Professional 120W Mixer Amplifier With Integrated Usb And Bluetooth Capabilities, Designed For Public Address And Background Music Applications. User Interface: The Amplifier Shall Feature A Simplified User Interface With Preferred Setting Indicators (Colored Pins) For All Front-Panel Knobs To Ensure Ease Of Operation For Non-Technical Users. It Must Include An Led Vu Meter For Visual Output Level Indication And A 6.3 Mm Headphone Socket For Monitoring The Mixer Output. Reliability: The Unit Shall Have No Moving Parts (Such As Hard Drives) To Ensure Long-Term Operational Reliability. Audio Inputs And Media Source Microphone/Line Inputs: Four (4) Balanced Inputs, Switchable Between Microphone And Line Level Sensitivity. Switchable Phantom Power Must Be Available To Support Condenser Microphones. Priority Handling: Input 1 Shall Have The Capability To Take Priority Over All Other Inputs Via Contact Closure (Push-To-Talk) And Include An Optional 2-Tone Chime To Precede Announcements. Music Source: Integrated Media Player: Must Support Playback Of Mp3 And Wav Files (From 32 Kbit/S) Via A Usb Pen Drive (Up To 32Gb Capacity). Wireless Streaming: Built-In Bluetooth For High-Quality Audio Streaming From Mobile Devices. Remote Control: The Unit Must Be Supplied With An Ir Remote Control For The Integrated Music Source. Aux Input: A Separate Stereo Cinch Input, Internally Converted To Mono, With A Sensitivity Of 200 Mv To 300 Mv. Audio Performance And Output Output Power: 120W Rated Output Power. Loudspeaker Outputs: Constant Voltage: 100 V. Low Impedance: 4-Ohm. Call-Only Output: A Dedicated 100 V Call-Only Channel For Priority-Only Areas Or 3-Wire Remote Volume Control Override. Frequency Response: 80 Hz To 18 Khz (+1/-3 Db At -10 Db Ref. Rated Output). Distortion: 1% At Rated Output Power (1 Khz). Tone Control: Dedicated Bass And Treble Controls Providing Max ± 8 Db Adjustment. System Protection: An Integrated Limiter Circuit Must Be Included To Protect The Output Stage From Signal Clipping And Overload. Insert Feature: A Pair Of Rca Cinch Connectors Shall Be Provided To Allow The Unit To Be Used As A Separate Pre-Amplifier And Power Amplifier. Mechanical And Environmental Dimensions: 100 Mm X 430 Mm X 290 Mm (Standard 19 Wide, 2U High). Mounting: Suitable For Both Stand-Alone Use And 19 Rack Mounting. Operating Temperature: -5 °C To +45 °C. Compliance: The Unit Shall Comply With Iec 62368-1 (Safety), Cispr 32 (Emc Emission), And En 55103-2 (Emc Immunity). , Mixing Console General Requirements The Mixing Console Shall Be A Compact, Versatile 6-Channel Analog Mixer Designed For A Wide Range Of Professional Audio Applications. It Must Feature High-Quality Microphone Preamplifiers And A Rugged Construction Suitable For Both Portable And Fixed Installations. Audio Inputs And Processing Input Channels: The Unit Shall Provide A Total Of 6 Line Inputs, Configured As 2 Mono And 2 Stereo Channels. Microphone Preamplifiers: The Console Shall Include 2 Microphone Inputs Featuring Discrete Class-A D-Pre Preamps With An Inverted Darlington Circuit For Superior Sound Quality. Switchable +48V Phantom Power Must Be Available For All Microphone Inputs. Channel Processing: Mono Inputs (Ch1-2) Shall Include A 26Db Pad For High-Level Sources. Each Mono Channel Shall Feature A High-Pass Filter (Hpf) Set At 80Hz With A 12Db/Octave Slope. Equalization For Mono Channels Shall Consist Of A 2-Band Eq: High (10Khz Shelving) And Low (100Hz Shelving) With Pm15 Db Adjustment. Output And Bus Section Buses: The Console Shall Feature 1 Stereo Bus. Outputs: Stereo Out: Provided Via 2 Xlr-3-32 And 2 Phone Jacks (Balanced). Headphones: One (1) Stereo Phone Jack Output With A Dedicated Level Control. Monitoring: Visual Monitoring Shall Be Provided By A 2 Times 7 Point Led Level Meter (Peak, +6, +3, 0, -3, -10, -20Db). Technical Performance Frequency Response: Pm 0.5Db From 20Hz To 20Khz (Referenced To Nominal Output Level @ 1Khz). Total Harmonic Distortion (Thd): 0.01% @ +8Dbu (20Hz To 20Khz), Gain Knob: Min 0.003% @ +18Dbu (1Khz), Gain Knob: Min Hum & Noise: Equivalent Input Noise Of -128 Dbu (Mono Input Channel, Rs: 150Ω, Gain Knob: Max) Crosstalk: -88Db @ 1Khz. Mechanical And Electrical Specifications Chassis: The Unit Shall Be Housed In A Robust, Impact-Resistant, Powder-Coated Metal Chassis. Power Supply: External Ac Adapter: Pa-130 (120V 60Hz) Or Mu18 (100-240V 50/60Hz) Or Equivalent. Power Consumption Shall Be Approximately 12W. , Indoor Wi-Fi6 Access Point General System Requirements Type: The Unit Shall Be A High-Performance, High-Speed 11Ax (Wi-Fi 6) Indoor Dual-Band Ceiling-Mounted Wireless Access Point (Ap). Standard Support: The Wireless Access Point (Ap) Shall Strictly Adhere To The Ieee 802.11Ax (Wi-Fi 6) Standard. Radio Configuration: The Unit Must Be A High-Power Industrial Ceiling-Mounted Ap Featuring 2X2 Mimo Technology For Both 2.4 Ghz And 5 Ghz Bands. Performance: The System Must Provide A Combined Wireless Data Rate Of Up To 3 Gbps To Support High-Speed Applications Such As 4K/8K Streaming And Vr/Ar. User Capacity: The System Shall Support A High Density Of Users, Accommodating Up To 128 Concurrent Users (Max 64 Users Per Band). Advanced Features: The Ap Shall Support Multi-User Mimo (Mu-Mimo), Orthogonal Frequency Division Multiple Access (Ofdma), Bss Color Bit, And Dynamic Cca-Sd For Improved Interference Management. Hardware Specifications Chipset: The Ap Shall Be Equipped With A High-Performance 4-Core Qualcomm Chipset. Ram: 512Mb Ddr3. Antenna: Integrated Internal 4X4Dbi Dual-Band Mimo Antennas. Combined Rate: A Concurrent Wireless Rate Of Up To 3000 Mbps. Physical Interfaces: 1 X 10/100/1000Mbps Wan/Poe Port. 1 X 10/100/1000Mbps Lan Port. 1 X Reset Button. Provision For A Dc2.0 12V 1.5A Power Connector. Support For Power Over Ethernet (Poe) Following Ieee 802.3Af/802.3At Standards. Thermal Management: The Unit Shall Feature A Heat Sink With A Snap-On Structure And Special Surface Coating To Optimize Heat Dissipation. Indicators: Led Status Lights For Power, Cloud Connection, Lan Speed, 2.4Ghz Status, And 5.0Ghz Status. Audio & Network Management Quality Of Service: Must Support Wmm (Wireless Multimedia Prioritization). Roaming: Support For Seamless Roaming To Ensure Uninterrupted Connectivity For Mobile Clients. Deployment: Flexible Deployment Options Including Standalone Mode, Mobile App Management, And Zero Touch Provisioning (Ztp). Network Management: Support For Vlan Settings, Cloud Access (In Gateway Mode), And System Logging. Management: Support For Remote Configuration And Management. Maintenance: Features For Backup/Restore Configuration, Factory Reset, Scheduled Reboots, And Lifetime Firmware Upgrades. Security Requirements Encryption: Must Support Wi-Fi Protected Access 3 (Wpa3) And Wired Equivalent Privacy (Wep) 64-Bit, 128-Bit, And 156-Bit. Access Control: Integrated Mac Address Filtering And Wireless Access Control To Identify Authorized Devices. Management Security: Secure Socket Layer (Ssl) For Remote Management Login And The Ability To Block Ssid Broadcasting. Environmental & Reliability Operating Limits: Working Temperature: -10°C To 55°C. Storage Temperature: -40°C To 70°C. Humidity: 5% To 95% Non-Condensing. Protection: Esd: Air ±8K, Touch 6K. Electrical Surge: Common Mode 2K, Differential Mode 1K. Power Efficiency: Maximum Power Consumption Shall Not Exceed 16 Watts. Oem Warranty And Support Local Presence: The Original Equipment Manufacturer (Oem) Must Have An Authorized Service Center Or Registered Office In Madhya Pradesh (Proof Of Gst/Msme/Registration Required With Bid). Warranty: A 2-Year On-Site Hardware Replacement Warranty Is Required, With New Hardware Provided Within 12 Hours Of A Call Lock (No Refurbished Or Repaired Products). Technical Support: On-Site Support Must Be Available Within 6 Hours Of A Request. Future Warranty & Support: Oem Must Have Warranty And Support Pack Purchase Option Before Expiry Of Warranty Period For Next Years. Service Availability: The Oem Must Provide A 24X7 1800-Series Toll-Free Number With Support Available In The Local Hindi Language. Product Life Cycle: The Quoted Product Must Have A Life Cycle Of No Less Than 5 Years From The Date Of Supply, Including Lifetime Free Firmware And Technical Assistance. Certifications: The Product Must Be Ce, Fcc, Rohs, Iec 15408 And Iso 9001. Certified. Bidder Must Have To Submit Compliance On Oem Letter Head Along With Maf. , Network Wall Mount Rack Must Have To Supply And Installation Of 15U 500X550 Network Wall Mount Rack With Glass Door And Lock With Hardware, 6 Socket Industrial Pdu 15Amp With Mcb, Cable Manager, Fan, Hardware And Etc. , Goosneck Mic Cable, Speaker Cable In Meter, Installation And Accessories Complete Job Work With Required Cables, Frpvc Conduit, Accessories, Fitting, Installation And Etc.
Contract Date: Jun 09, 2026 Contract Value : 2.02 Lakh
Local Bodies No of Bidders 3
Madhya Pradesh View Result →
4.
Defence #11097521 AOC
Tender For Provision Of One Mega Watt Solar Power Project Under Ge (I) (P) No 2.; 1 Supply and fixing of MS fabricated office container of size 15x8x8.5 feet with toilet cabin of size 5x4 feet for SCADA panel and local monitoring for accomodating portable shelter , office, or living space in high alttitude cold region with including PCC flooring work for installation of container including fixing arrangement completeall as specified and directed.Location conditionTemparature range -30 °C to +25°CAltitude -3500m above sea levelwind speed upto 120 km/hSnow load high (snow accumulation on roof)Readymade container shall include the following(a) Attached toilet with EWC/IWC pressure jet gun, water tap, exhaust fan, corner wash basin, tiles flooring, water tank stand , gyser provision, wall mixer and other accessories required for said locations conditions. 2 (b) Container shall include bottom frame 100mmx50mm C channel ISI marked, Top frame of size 50mmx50mm MS square pipe ISI marked , stiffener bottom 100mm x50mm, 50mmx25mm, 25mmx25mm MS square pipeISI marked stiffener top 50mmx25mm, 25mmx25m MS square pipe ISI marked, side post 50mmx50mm, 50mmx25mm MS square pipe ISI marked, Side wall stiffness specially formed CR sheets of thicknes 1.2mm internal wall panelling 8mm thick MDF and all vertically and horizontal corner will be nealty and smoothly finished with aluminium section and L angle, Roof outside 1.2mm thick sheet of make properly sloped and water tight, false ceiling 9mm thick and smoothly finished with aluminium section and L angle, flooring 18mm thick cemented board of make visaka industries will be fixed by means of self taping screw and 1.5mm thick PVC vinyl carpet will be fixed on the panel (100% water termite and dimensional proof with veyl carpet) Aluminium windows double shutter sliding aluminium powder coated windows of thickness of 1.2mm with 4mm thick glass of make saint Gobin for all windows safety grill from outside and canopy above the floor frame work by tubular pipe of 25x25, Door with lock and handles with hydraulic door closer. Insulation 25mm thick glass wool insulation of density 65kg/m3 on side wall and 50mm on ceiling , all wiring will be PVC insulated copper wires of ISI quality, suitable for 240 volts 50 bukhead, switches and socket of 6Amp of ISI make. Split air conditioner point 16Amp alongwith seperate MCB earthing point will be provided for safety. Outside painting with 1 coat of Epoxy primer with 2 coats of epoxy paint and specially formed hooks for easy lifting and shifting. 3 Material and Labour for Plain fillets 2nd class softwood . square, rectangular or triangular in section, clean sawn, secured with screws of size exc 13 and not exc 25 Sqcm complete all as specified and directed. 4 Material and Labour for for prepration of wooden surfaces and applying a coat of pink primer for filletsof surface of any description not otherwise described over 10cm in width or girth complete all as specified and directed. 5 Material and Labour for50mm thick bonded mineral wool blanket slab made from rock, density 48kg/Cum and fixed as per manufactures instruction complete all as specified and directed. 6 Material and Labour for 9mm thick Prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination,fixed with nails on walls complete all as specified and directed. 7 Material and Labour for 9mm thick Prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination,fixed with nails on ceiling complete all as specified and directed. 8 Material and Labour for cement concrete type D2 1:4:8 (40mm graded agg)as in foundations filling mass concrete and all as specified and directed. 9 Material and Labour for Pre-cast cement concrete block masonry with solid blocks in 1:3:6 type C-1 using20mm graded crushed stone aggregates, exc. 10 cm in width or girthand setting in mortar 1:6, complete all as specified and directed. 10 Material and Labour for 100mm thick cement concrete 1:2:4 type B-2 using 40mm graded crushed stone aggregates as in flooring finished even and smooth without using extra cement complete all as specified and directed. 11 Material and Labour for renderring 15mm thick in CM 1:4 on fair faces of concrete surfaces finished even and smooth without using extra cement complete all as specified and directed. 12 Material and Labour for renderring 15mm thick in CM 1:4 on stone masonry surfaces finished even and smooth without using extra cement complete all as specified and directed. 13 Material and Labour for Walling of random rubble masonry, uncoursed well bonded bedded and solidly hearted built in CM 1:4 and flush pointing the surface in contact with earth in same mortar as the work proceeds complete all as specified and directed. 14 Supply and fixing of50mm thick PUF insulated water tank of capacity 5000 litres complete all as specified and directed. 15 Supply and fixing of50mm thick PUF insulated water tank of capacity 1000 litres complete all as specified and directed. 16 Supply, installation, errecting ,testing and commissioning of On grid connecting on ground Mono Perc half Cut Bifacial Solar photo voltaic (SPV) generation plant of capacity 825KWp DC capacity at standard test condition and750 KW AC capacity (Net capcity after derating), at CHUMATHANG for fixed on module mounting structure without tracking component including solar grade copper cable of suitable sizes upto Invertor,UPS for auxilliary supply to SCADA, string array combiner/ array junction boxes comprising of following sub components/sub systems including all necessary protection, control switches and relays as required for smooth functioning of the system and meeting the specifications as given and directed by Engineer-In-Charge, the quoted rates includes all components/accessories as given below and required from Solar panel to upto step up transformer 1000 KVA incomer termination complete all as specified and directed. 17 (A) Solar photo voltaic plant- : To obtain cumulative 825KWp, three tables of nearly equal size table (varaiation of 5% between table size is permissible) ofthe input of mono perc Half Cut Bifacial silicon solar PV modules of minimum or more than 540/545 Wp with minimum or more than 144 Nos solar cells preferably per module of standard size and weight as per NISE standard , frame anodised aluminium frame (double walled) with junction box IP 65 rated , each having efficiency more than 21% at standard test condition, fill factor more than 0.79 performance ratio equal to and greater than 78 % & made of high transmittivity glass as per NISE standard tempered and glass front surface shall give high encapsulation gain. (transmittance above 90% and bending less than 0.3%) Electrical parameters of 540/545 Wp solar PV module under STC of irradiance 1000 W/m2 , AM 1.5 Spectrum at temperature 25° C will be as under or higher :-Min Peak power Pmax : 540/545 Wp or higher, Current at Pmax Ipm : 12.97A Voltage at Pmax Vpm : 41.65 Volt Short circuit current Isc : 13.85 A Open circuit voltage Voc : 49.50Volts , Maximum series fuse rating : 30A (i) Rated output of modules shall have positive tolerance of minimum 3% & no negative tolerance is allowed. (ii) It shall perform satisfactorily in relative humidity 100% with temperature -35° C to +35° C (Cell) and should withstand wind 198 Km/Hr on the surface of the panel. (iii) PV modules must be warranted for their output peak watt capacity, which shall not be less than 90% of the initial value at the end of 10 years and 80% of the initial value at the end of 25 years. (iv) The temperature co-efficient for the module shall be suitable for CHUMATHANG (UT Of Ladakh) climatic conditions. Variation of higher capacity Solar PV panel is permissible subjected to that performance parameter of the panel shall be equal or better than given above.v) PV module must confirm to latest edition of IEC 61215/IS14286 and as specified here-in- after in particular specification In addition, the modules must confirm to IEC 61730 Part-I & II for construction and testing & safety qualification. (vi) It shall also in conformity of latest technical specifications issued by MNRE from time to time (vii) Provision of earthing & earth strip/cables etc. for earth for solar PV module/Array etc. as per latest IS/MNRE norms to be provided and the cost of the same is to be included in this item and no extra amount will be paid to the contractor on this account.Notes: On SPV (i) The specifications and capacities of plant equipments shall be designed to confirm and achieve the minimum of efficiency and performance guarantees as laid down in this bid documents. These design details and other technical details shall be submitted by contractor on commencement of contract as early as possible but not later than one month(ii) The installed system should be such that during the day, the power needs should be first met by Solar energy. In case the solar energy production is less than the required, the deficit power should be pulled from the exsiting DG set supply .(iii)The contractor shall obtain the approval of make for the proposed SPV module from accepting officer complete system of 825 KWp Solar photo voltaic (SPV) (iv) Any necessary item required for functioning of SPV but not catered in the contract will be deemed to be included in the quoted rate and nothing extra will be admissible on this account 18 .(v) Site clearance incl removal of boulders to a distance 250 m to 500m to be carried out before execution of work. Amount required for site clearance is deemed to be inclulded in the amount quoted by Contractor against this item. Contractor is advised to visit the site before quoting the rate. (vi) Country of origin for solar cell & PV module must confirm to ALMM APPROVED LIST OF MNRE.(B) String array combiner/Junction Boxes: Supply & fix suitable Numbers of dust, vermin and waterproof Array string array combiner/Junction Boxes and main junction boxes made of FRP/Thermo Plast with IP65 protection in compliance with IEC62208 and shall be sunlight /UV resistant a well of fire retardant including over voltage protection, surge protection and maintenance free earthing as per relavant standard. The string array combiner/Junction boxes shall have suitable arrangement of followings:(i) Strings are required to be connected to the busbar through individual fuses. Provide arrangement fordisconnection for each of the groups (ii) Provide a test point for each subgroup for quick faultlocation & to provide group array isolation. (iii) Each array junction box will have suitable by pass &reverse blocking diodes for maximum DC blocking voltage of 1500V with suitable arrangement for its connection. Reverse blocking & by-pass diodes shall work for temperative extreames & shall have efficiency of 99.98% conformed by appropriate IEC standard. Note:- String array combiner/ junction box shall be carried out as per approved SLD.(C) Cabling : (i) Supply and fixing suitable size of XLPO insulated copper cable as per load of solar grade, 1800 V DC/1100 V AC or higher DC voltage rating, confirming to TUV 2 pfg 1169/08.2007 PV1F and latest IEC codes & IS codes for Solar Cables. (ii) All cables and connectors for use of installations shall be of solar grade which can withstand harsh environment conditions including high temperature, UV radians, rain. humidity, dirt, burial and attack by moss and microbes for 25 years and voltage as per latest IEC/IS in standards. (iii) All cables/wires shall be provided with UV resistance printed copper ferrules for DC side. (iv) Size of cable from PV module to invertor shall be minimum 6 sqmm 1 core multistranded copper UV protected solar cable to be provided. (v) Cable Batch No./Drum No., IS code & size make should be printed/embossed at every one metre. (vi) The wiring of modules interconnection shall be in suitable size GI/HD pipe. (vii) Size of wire - 3.70mm dia with tolerance limit (+/ -) 0.08mm. (viii) Size of aperture - 80mm x 100mm (ix) Woven double twisted, hexagonal shaped Zn + PVC coated wire mesh type 80 x 100mm of wire 3.70mm dia wire as per IS 16014. The wire used for the manufacture of wire mesh shall have minimum tensile strength of 350N/mm2 and elongation shall not be less than 10% in accordance with IS 16014.To be laid in DWC pipe of suitable size. (xi) Solar inverter to ACB Panel, connection aluminium XLPE conductor cable of size 185 sqmm x 3C 1.9/3.3 KV rating Note : Cost of interconnecting copper cable (AC & DC), Al XLPE cable from Solar Invertor to ACB panel and cable tray above upto inverter and LT panels and upto LT side of transformer as per site requirement at the location as directed deemed to include in the item quotated rates and no extra payment will be made to contractor on this account. LT Panel shall be paid seperately. 19 (D) Module Mounting Structure (MMS) : Supply, design & fixing support structure MS hot dipped galvanised (80Micrones) including PCC 1:2:4 type B-1 for each support / foundation for civil works (excavation and earth work cutting, grouting, PCC etc.) and fixing the mouting arrangement suitable for PV solar modules & to withstand minimum horizontal wind speed of 198km/hr. The mounting structure is of mild steel hot dipped galvanised. The array structure shall be so designed that it will occupy minimum space without sacrificing the output from Solar PV panels. Nut bolts, supporting structures including module mounting structures shall have to be adequately protected from atmosphere and weather prevailing in the area. All fastners shall be of stainless steel of grade SS316. Two numbers of anti-theft fasteners of stainless steel on two diagonally opposite corner of each module shall be provided.Note: (i) Cost of interconnecting copper cables along with cable trays ( floor/ wall mounted ) suitable to accommodate solar grade cables & cables upto inverter is included in the item and no extra payment will be made to contractor. (ii) The module mounting structure shall be carried out as per approved drawing of foundation MMS. MMS foundation shall be designed as per IS 456:2000 and IS 13920:2016 and drawings shall be approved by GE before execution. (iii) The MMS stub/column,rafter,purlin ,ties and bracing members shall conform to following indian standard :IS 2062 -Hot rolled medium and high tensile structural steel ,IS 811-Cold formed light gauged structural steel section ,IS 1161-steel tube for structural purposes, IS4923- Hollow steel section for structural use. Minimum grade of steel sections for conforming to IS 811 and IS 4923 shall be E350 conforming to IS 2062 and Yst 310 conforming to IS 1608 respectively.(E) Lightning Protection for PV Array :- Supply & fix Lightning Arrestor of the required number of suitable Early Streamer Emission (ESE) lightning arrestors installed in the array field. Lightning arrestors/surge arrestors shall conform to IEC 60099-4 or IS:3070 except to the extent modified in the specifications. Arrestors shall be of hermetically sealed units, self-supporting construction, suitable for mounting on lattice type support with the following :-(i) The air terminal should be capable of racking the lightning stroke 60 micro seconds earlier as compare to passive lightning rod. (ii) The air terminal is Early Streamer Emission (E.S.E.) type which shall be fixed at the top of a GI elevation pole with base so as be at least 2 meters above the structure to be protected. Its height above roof level would be dependent on the level of protection and the protection radii required (iii) The air terminal should be working on the principle of early streamer emission using non-radioactve technology, needing no external power source. (iv) The air terminal is of stainless steel and it has qualified diameter to resist high values of lightning currents. (v) Roof connecting pipe should be capable of withstand in lightning strikes having dimension 50mm ID and 60mm OD. The terminal adaptor having inner dia 60mm OD. Lightening protection shall be provided as per approved Drg. 20 (F) Earthing system for PV array field :-Earthing system shall comply with latest revision andamendment of the relevent IEC standard and IS codes. (i) All PV module ,module mounting structure (MMS) and string monitoring unit (SMU) structures in the PV erray field shall be connected to the earthing system (ii) Each PV module frame shall be earth using copper wire of sufficient cross section area. Earthing complete with copper earth plate electrode 600×600 ×3.15 mm thick electrode, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level connected to 20x3 mm copper strip as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel and 40mm dia GI pipe light grade for protection of earth strip and 20mm dia meduim grade for water funnel with wire mesh complete connected to earthing test point as per SSR Part-I 2009 all as specified and directed including testing on completion.NOTE:- Cost of all Copper plates earthing equipments including Copper earth strips from equipments to earth pit is deemed to be included in quoted rates.(G) Solar Inverter : Supply, fixing, testing and commissioning of minimum of suitable capacity in suitable Nos as per 250/255 KW (Total capacity of Inverters shall not be less than 750/755 KW after derating with three inverter) for CHUMTHANG 50 Hz , 3 phase 800V,185A Grid Connected Solar inverter outdoor type suitable to convert DC power of solar PV module/array to AC for further feeding to stepup transformer conforming to IEC-61683 for efficiency, IEC-62109(1&2) or equivalent for safety & IEC-62093 for reliability. The input D.C. tech specification of inverter are as under and as per approved design.(i) Operating temperature :-40ºC to + 35ºC,(ii) Relative humidity (Non condensing) upto 95%.(iii) The inverter shall consist of associated control, protection, data loging device and remote monitoring hardware. the inverter shall be suitable for operation at Chumathang .Alt 4200 mtr and min - 40ºC temperature.(iv)The inverters shall have minimum protection to IP65 and minimum European efficiency 99% load as per IEC 61683 standard.(v) The inverter shall adjust voltage and frequency levels to suit the existing DG Sets/AC power supply. (vi) The inverter shall be self-commulated with pulse width modulation (PWM) technology and shall be capable of synchronize maximum within 1 minute.vii) Maximum power point tracker (MPPT) conforming IEC- 62093 shall be integrated in the inverter to maximize energy drawn from the solar PV array. (viii) The inverter shall include appropriate self protection & self diagnostic feature to protect itself and the PV array from the damage in the event of inverter component failure or from parameters beyond the inverters safe operating due to internal or external causes. 21 (ix) Inverter shall have protective arrangement against ground leakage faults, over voltage & over current. (x) Inverter shall have arrangement for adjusting DC input current & shall trip against sustainable fault down stream and shall not restart till fault is rectified. Notes: (i) If the solar inverter as specified here-in-before is not available in the market , contractor will provide the same of higher capacity as available in the market without any extra cost. (ii) All suitable size of copper cables as per load requirement from SPV systemto inverter for interconnection purpose shall be provided by the contractor and deemed to be included in quoted rates. (iii) Cost of all Copper plates earthing equipments including Copper earth strips from equipments to earth pit is deemed to be included in quoted rates.(H) Uninterrupted power supply(UPS) : Supply, installation, testing & commissioningof 110V/40A Float Cum Boost Battery Charger unit includingbattery bank comprising 50 Nos of 2 Volts-65 AH sealed maintenance free battery.The CCCV battery charger consisting ofcopper wound,air cooled transformer, 01 Set single phase full wave bridge rectifier consisting ofdiodes andSCRs, liberally rated mounted on heat sink andcomplete with resistor/condenser network for surge supperssion .During auto float mode automatic changeover shall take place from float mode to boost mode and vice versa, 01 Set of solid state constant potential controller to stabilize the DC output voltage of the float cum boost charger, 01 No electronic controller , DCdigital ammeter,DC digitalvoltmeter, Potentiometer , DC, MCB for reverse battery protection . The charger should have alarm annunciation with visual and audible alarm with manual reset facility forfuse fail alarm. Float cum boost battery charger and DC distribution board shall be housed in powder coated sheet steel cubicle with panels of 1.6mm thickness , louvers for ventilation , gland plate will be provided for cable entry from bottom .The battery charger shall be divided into two compartments.The upper compartment shall house the battery charger & DCDB with all necessary controls. The lower compartment shall be suitable for housing the batteries. Tech specification shall be as under:-(a) Input working voltage-180 -270 Volts(b) Nominal Input Voltage - 230 V , AC , 50 Hz,1 (c) On load input power factor- > 0.8 (d) On load unit watt efficiencies-> 80%(e) No load losses of complete charge-< 10% (f)Ripple contents on the load (RMS)= 1% to 5% (g) Over load - 110% for 30 minutes and will give visual indication for over load condition. (h) Boost charging - 2.4 V/Cell . (j)Float charging -2.15 V/Cell (k)Float cum boost charging-Automatically changes from one state to another state as per battery condition and will give the visual indication for either float or boost based on charging mode. (l)Reverse polarity -No damage will caused .A visual indication for reverse polarity will appear with an audio alarm. (m)Short circuit-MCB protecton provided. Make of battery charger. Statcon/Sinetrac/Amar Raja Make of batteries. Exide/Amaron/Okaya(n) The battery bank system shall be designed to supply power to following loads :-(i) SCADA(ii) Inverter auxillairy supply 22 (iii) Capacity of battery bank shall be done considering the above mention load at power factor of 0.8 lagging inclusive of 10% design margin at 50ºC.Note:- All suitable size of copper cables as per load requirement for interconnection to above loads here-in-before shall be provided by the contractor and deemed to be included in quoted rates(J) DATA ACQUISITION SYSTEM/PLANT MONITORING & SCADA :- Supply,fixing,testing and commissioning of SCADA system Monitoring system with 65 inch Screen at site with Local LDMS and for Remote Monitoring 55 inchs screen in Engineer-in-charge office to be provided for the performance of the SPV on cloud. plant, inverter ,power, array voltages, array currents & AC parameters,energy yield, temperature,irradiance level etc. and it could provides flexible interface to facilitate PC based inverter monitoring and control via GPRS modem and internet/ethernet connection. This should have include web visualization system and data logger with integrated ethernet port. (i) Data acquisition System shall be provided for each of the solar PV plant. (ii) Data Logging Provision for plant control and monitoring, time and date stamped system data logs for analysis with the high quality, including latest version available of PC & Printer. Metering and Instrumentation for display of systems parameters and status indication to be provided (iii) Solar Irradiance: An integration Pyranometer/Solar cell based irradiation sensor (along with calibration certificate) provided, with the sensor mounted in the plane of the array. Readout integrated with data logging system. (iv) Temperature: Temperature probes for recording the Solar Panel temperature and ambient temperature to be provided complete with readouts integrated with the data logging system.(v) The parameters like AC Voltage, AC Output current, Output Power, Power factor, DC Input Voltage, DC Input Current, Time Active, Time disabled, Time Idle, Energy Produced, Protective function limits (Viz-AC Over voltage, AC Under voltage, Over frequency, Under frequency ground fault, PV starting voltage, PV stopping voltage etc are accessible via the operating interface display in real time separately for solar power plant. (vi) All major parameters available on the digital bus and logging facility for energy auditing through the internal microprocessor and read on the digital front panel at any time and logging facility (the current values, previous values for up to a month and the average values) should be made available for energy auditing through the internal microprocesor and should be read on the digital front panel. (vii) PV array energy production: Digital Energy Meters to log the actual value of AC/DC voltage, Current & Energy generated by the PV system provided. Energy meter along with CT/PT should be of 0.5 accuracy class. (viii) Computerized DC String/Array monitoring and AC output monitoring shall be provided as part of the inverter and /or string/array combiner box or separately (ix) String and array DC Voltage, Current and Power, Inverter AC output voltage and current (All 3 phases and lines), AC power (Active, Reactive and Apparent), Power Factor and AC energy (All 3 phases and cumulative) and frequency shall be monitored. (x) Computerized AC energy monitoring shall be in addition to the digital AC energy meter. 23 (xi) The data shall be recorded in a common work sheet chronologically date wise. The data file shall be MS Excel compatible. The data shall be represented in both tabular and graphical form (xii) All instantaneous data shall be shown on the computer screen. (xiii) Provision for Internet monitoring and download of data including recharging shall be also incorporated till the duration of contract. (xiv) Software shall be provided for USB download with life time license and analysis of DC and AC parametric data for individual plant (xv) Remote Server and software for centralized Internet monitoring system shall be also provided for download and analysis of cumulative data of all the plants and the data of the solar radiation and temperature monitoring system. (xvi) Ambient /Solar PV module back surface temperature shall be also monitored on continuous basis. (xvii) Simultaneous monitoring of DC and AC electrical voltage, current, power, energy and other data of the plant for correlation with solar and environment data shall be provided. (xviii) Remote Monitoring and data acquisition through Remote Monitoring System with latest software/hardware configuration and service connectivity for online/real time data monitoring/control complete to be supplied and operation and maintenance/control to be encurred by the supplier. Provision for interfacing these data on Engineer-In-Charge Computer/display device and portal.NOTE:- The cost of all equipments , internet, ethernet connections, connected cables, Server, printer etc. are included in this item All licensee of windows server, MS office or any other software required for functioning of SCADA is deemed to be included in quoted rates for life time. Recharge of GPRS/3G/4G/5G network for 5 yrs from date of completion shall be reponsibilty of contractor and rates quoted are deemed to include the same. Training: On successful commissioning of the plant, training shall be provided on Plant operations and maintenance to a team (Engineers and Technician/Operations) as nominated by GE for 07 days at the time of handing over of solar plant after completion of phase-I.K) WEATHER MONITORING SYSTEM : Complete one set for Chumathag As a part of weather monitoring system the contractor shall provide the following measuring instruments with all necessary software and hardware required to integrate with SCADA.(i) Pyranometer : The contractor shall provide minimum 04 Nos of secondary standard pyranometer (ISO 9060 classification alongwith necessary assessories for measuring incidental solar radiation at horizontal and inclined plane of array. Specificiation of the pyranometer shall be asfollows:- Spectral response : 0.31 to 2.8 micron ,Time response (95%) : Max 15 second ,Nonlinearity ± 0.5% ,Temperature response : ± 2% ,Tilt error <± 0.5% ,Zero offset thermal radiation ±7W/Sqm ,Zero offset temperature change ± 2 W/Sqm ,Operating temperature range O ºC to 80ºC ,Non stability Maximum ±0.8% ,Resolution minimum +/- 1 W/Sqm : Output Analog 4-20 mA, ,Digital RS 485 Each instruments shall be supplied with necessary length of cable calibration certificate with calibration ,traceability to world radiation reference(WRR) or world radiation centre shall be furnished alonwith the equipments.The GE reserves the right to check the calibration at the expense of the contractor. 24 The signal cable length shall not exceed 20 m .The contractor shall provide instrument manual in hard and soft form.(L) Protection switch gears: Supply, installation, testing and commissioning of factory made outdoor type, LT panel weather & vermin proofsuitable for 3 phase 415 V made out of 3.15 mm thick with internal partition of 1.6 mm thick MS sheet duly powder coatedand both sides openable with lockingarrangment and aluminium busbar of capacity not less than 2000 Amp, outdoor type , frame factory fabricated , duly powder coated painting having thickness not less than 100 microns provided suitable gasket, suitable for 3 Phase4 wire, 415 Volts, 50 Hz, AC supply system, including the following :- (a)ACB 1250 Amps capacity adjustable type , 4 pole 50 KA, 800 V, 50 HZ draw out type breaking capacity 50 KA( Icu=Ics=Icw=50KA) microprocessor protection. (b) MCCB 400 A, 4 pole, 415 volts, 50 Hz - 03 Nos (C) Bus bar chamber with and including aluminium strip (set 4 Nos) suitable for 800 V duly moounted on porcelain insulators -01 Set (d) Digital amp meter 3 ph programmeable type with suitable1600 Amps -01 Set (e)Digital volt meter 3 ph programmeable type with suitable0- 800 volts -01 Set (g) CT 1250/5A/5A, PT 100VA CL 0.5/3P (h) LED phase indicator (RYB )-01 Set. All DC & AC circuits shall be suitably protected using appropriate circuit breakers and isolators, fuses and relays annunciator & system condition displays. Protection switchgears on AC side shall have LT ACB 1250 Amps capacity adjustable type , 4 pole 50 KA, 800 V, 50 HZ draw out type breaking capacity 50 KA( Icu=Ics=Icw=50KA) microprocessor protection based with overload ,short circuit over voltage, under voltage, over frequency , under frequency , earth fault and instantaneous over current protection unit , electrically operated with manual spring charge facility , having indication for earth /over load /overvoltage/ under voltage/ over frequency/ under frequency complete with digital meter. Note:- Panelshall be provided as per approved SLD.(M) Cable Duct / Conduit DWC Pipe : Cable duct/ cable tray of appropriate size from solar panel to inverter/ transformer and cable duct made from PCC etc incl MS plates duct cover 6 mm thick (plain orchequered) channels square cut or notched ( ordinary & counter sunk) forming holes without any attachment complete all as spd and directed.Note: (a) There should be provision of vertical separation between power and control cable duct. (b) Cable ductshall be provided as per approved drg . 25 Supply, installation testing and commissioning of outdoor type step up transformer Inverter duty type low losses of 1 MVA, 0.800/11KV, 3 phase, 50 HZ, ONAN Cooled oil immersed copper wound out door type Step up Transformer delta/delta (Δ/Δ) complete with first oil filling and other standard fitting / accessories and Off load tap changer (Taping Range ± 5% in step of 2.5% each) suitable for feeding supply generated from solar power plant to existing transmission line with Including the following : 26 HV Bushing 33 KV and LV Cable Box suitable for chumathang area of Alt 4200 m along with necessary bus bars with adaptor box suitable for terminating incoming cables from inverter. Marshalling Box (having TTB Only ) all as specified and directed (i) Buchholz Relay trip contact and shut off valves. (ii) PRVRelay Trip (iii) Oil temperature indicator 150 mm dia with alarm and trip contact. (iv) Winding temperature indicator with alarm and trip contacts (v) Marshalling box 200 TB (MK) -03 Nos (6 No of terminal , 3 phase primary and 3 phase secondary, Bolted or plu in type terminal, cable entry 3X 50 sqmm (primary) and 3 X 120 sqmm (secondary) cable ties, clips or trays ) (vi) Magnetic oil level gauge. (vii) Pressure release valve (PRV) with trip contacts.(viii) Conservator with oil filling hole with cap and drain plug and wit built in diaphragm to avoid direct air contact with transformer oil. (ix) Oil level indicator with minimum level marking.(x) Thermometer pockets with thermometer. (xi) Silica gel breather (xii) Air Release plug. (xiii) Lifting Lugs (xiv) Earthing terminals (xv) Bi-directional Rollers (xvi) Anodized aluminum rating and diagram plate. (xvii) Off load Tap changer including indoor remote control panel. (xviii) Top filter valve (xix) Including transformer platform as per OEM recommendation is deemed to be included in quoted rates.Following protections shall be integrated with RMU Necessary equipments/metering devices shall be instaled in transformer.(a) Instantaneous overcurrent (b) AC time over current (c) Neutral & residual instantaneous over cuurent (d) Neutral & residual time overcurrent (e) master trip (f) anti pumping (g) trip circuit supervision (h) DC failure (i) WTI and OTI (j) pressure relief (k) Buchholz (l) Differential protectionNOTE:-The following works /items shall deemed to be included in the above quoted rates and no extra payment shall be made to the contractor on this account. (i) The erection /installation of transformer with suitable size of foundation as per OEM recommendation is deemed to be included in quoted rates (ii) Rates quoted is inclusive of all control cables of suitable size and core(as per manufacturer recommendations) from buchholz relay, PRV, OTI & WTI of power transformer to various controls ie CTS/PTs & HT panel and control panels. (iii) LT single core cable /LT bus bar of suitable size and capacity from LT panel to step up transforemers LT side including appropriate size of cable lugs as required at site for connection complete all as specified and directed. (iv) The step up transformer shall be suitable for inverter input to avoid/reduce/capable for odd harmonics and heat losses. 27 Supply, installation testing and commissioning of outdoor type distribution low losses as per Level II part I (IS:1180) of 1.25 MVA, 0.415/11KV, 3 phase, 50 HZ, ONAN Cooled oil immersed copper wound out door type Step up Transformer delta/star (Δ/Υ) (complete with first oil filling and other standard fitting / accessories and Off load tap changer (Taping Range ± 5 % in step of 2.5% each) suitable for feeding supply generated from solar power plant to existing transmission line with Including the following : 28 HV bushing and LV Cable Box along with necessary bus bars with adaptor box suitable for terminating incoming cables frominverter. Marshalling Box (having TTB Only ) all as specified and directed (i) Buchholz Relay with alarm and trip contact and shut off valves. (ii) Oil temperature indicator 150 mm dia with alarm and trip contact. (iii) Winding temperature indicator with alarm and trip contacts (iv) Marshalling box 200 TB (MK) -03 Nos (v) Magnetic oil level gauge. (vi) Pressure release valve (PRV) with trip contacts. (vii) Conservator with oil filling hole with cap and drain plug and wit built in diaphragm to avoid direct air contact with transformer oil. (viii) Oil level indicator with minimum level marking. (ix) Thermometer pockets with thermometer. (x) Silica gel breather (xi) Air Release plug. (xii) Lifting Lugs (xiii) Earthing terminals (xiv) Bi-directional Rollers (xv) Anodized aluminum rating and diagram plate. (xvi) Off load Tap changer. (xvii) Top filter valve (xviii) Differential relay protection for power transformer Following protections shall be integrated with RMU Necessary equipments/metering devices shall be instaled in transformer.(a) Instantaneous overcurrent (b) AC time over current (c) Neutral & residual instantaneous over cuurent (d) Neutral & residual time overcurrent (e) master trip (f) anti pumping (g) trip circuit supervision (h) DC failure (i) WTI and OTI (j) pressure relief (k) Buchholz (l) Differential protectionNOTE:-The following works /items shall deemed to be included in the above quoted rates and no extra payment shall be made to the contractor on this account. (i) The erection /installation of transformer with suitable size of foundation as per OEM design is deemed to be included in quoted rates .(ii) Rates quoted is inclusive of all control cables of suitablesize (as per manufacturer recommendations) from different relays buchholz relay of power transformer to various controls ie CTS/PTs & HT panel and control panels. (iii) LT single core cable /LT bus bar of suitable size and capacity from LT panel to step up transforemers LT side including appropriate size of cable lugs as required at site for connection complete all as specified and directed. (iv) The transformer shall be suitable for inverter input to avoid/reduce/capable for odd harmonics and heat losses. 29 Supply, installatioon , testing and commissiooning of factory made outdoor type 4 Way 2x630 Amp SF6 + 2x630Amp LBS out door type 11 KV Ringmain Unit with Space Heater at Altitude 4200m, 630 Amps IAC 20 KA for 3 sec suitable for solar power system confirming to relevant IS/IEC, LSC 2B having following specification and comprising of following:- (i) Electrolytic copper bus bars, droppers and bus bar should be insulated with full system voltage sleeves. Each SF6 breaker shall comprise of following 30 (ii) Trolly mounted vaccum circuit breaker as per IEC-62271-100 SF6 circuit breaker should have three Nos resin encapsulated vaccum bottles.(iii) Motorized spring charging mechanism 230V AC 50 Hz with integral spring charging handle for manual spring charging. (iv) Cast resin current transformer 11KV, 200/1-1A, Core-I: class 1.0, 5VA, core2:5P10,5VA.Bushing shall be of 11 KV (v) Cast resin potential transformer 11KV/√3/110V, 50VA, class 0.5Cl 3P, bushing shall be 11KV KV and HT fuse at the primary end and 4P MCB at secondary end of PT. (vi) Accessoories like local/remote switch, breaker control switch (T-N-C) space heater with thermostat, DC and AC control circuit through MCB, indicating lamps for RYB, spring charge, DC supply healthy, breaker ON/OFF , breaker in SERVICE/TEST. (vii) Multifunction meter with RS 485 port , on MODBUS Protocol. (viii) Digital ammeter and digital voltmeter. (ix) Master trip relay-01 No and Aux relay TCS, DC Fail, OC & E/F (x) Comprehensive numarical protection relay on MODBUS protocol compatiable for directional and non directional O/C, E/F, U/V, O/V protection, Pressure switch or gas density monito, Frequency relay, Breaker failure protectionTransfomer protection Bucholz protection, PRV,Differential protection, OTI, WTI Relay and panel should have following additional facilities:- (xi) Trip Ckt supervision, AC fail, DC fail (xii) Disturbance recorder. (xiii) Event log with date and time (xiv) Measurment and control feature (xv) Fully internal arc type tested. (xvi) SF6 bottles should be epoxy encapsulated. (xvii) Racking in/out, manual closing/tripping of CB with compartment door closed. (xviii) Breaker shall be provided with following contacts:- (xix) Auxilary switch with 6 No + 6 NC mounted on the draw out portion of the switchgear. (xx) Position switch with 3 NO + 1NC contacts for eachposition in SERVICE and TEST.(xxi) 16 window annunciater with hooter/alarm for OC,SC,OV,UV,TCS,DC Fail, AC Fail OTI,WTI,PRV,Bucholz, Differential, OF, UF, Gas density low, Breaker failure protection 31 Material and Labour for Earthing complete with GI earthplate electrode 600mm x 600mm and not less than 6 mm thick buried directly in ground (earth pit not less than 2.25m deep below normal ground level) with top edge of earth plate not less than 1.5m below normal ground level connected to GI strip of size 32x6mm by means of bolts, nuts, check nuts and washers of GI/steel all as shown in electric plate No 3 connected to equipmentscomplete and including char coal dust & salt filling in alternate layers (each layer shall be 15 cm thick)and GI protection pipe, medium grade 40mm dia and GI watering pipe 20mm, medium grade with funnel and wire mesh, 40mm thick pre-cast RCC, M-15 (nominal mix) cover reinforced with XPM weight not less than 4kg/sqm with suitable handle of 6mm dia MS bar and angle iron 40 x 40 x 3mm frame for cover, PCC M-15 (nominal mix) pit, excavation and earth work in any type of soil and connectedcomplete all as specified and directed. 32 Material and Labour for earthing complete with and including copper earth plate electrode 600 mm x 600 mm x 3.15 mm surrounded by a mixture of charcoal and salt in alternate layers burried directly in ground vertically in a pit of depth not less than 2.25 m deep below ground level with top edge of earth plate at a depth of not less than 1.5 m below ground level, connected to copper trip earth lead wire 25x6 mm dia by means of nuts, bolts, checknuts and washers made out of galvanised iron, 15 mm bore (light grade) GI pipe for protection of earthing lead, 20 mm bore (light grade) GI pipe for watering with funnel, wire mesh and including necessary excavation and earth work, PCC 1:2:4 type B-1 pit and 50 mm thick RCC M-25(Design mix) reinforced with XPM (weight not less than 3 kg/sq m) pit cover, C.I frame, charcoal and comman salt filling in alternate layers, complete all as shown and specified in electrical plate No. 3 of SI Part-I. 33 Material and Labour for Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr belowground level connecting to galvanisedearth lead wire 4mm dia by means of bolts,check nuts and washers and earth lead protected by provision of GI pipe light grade 15mm bore including provn of concrete pit in PCC (1:2:4) type B-1 using 20mm graded crushed stone aggregates with 40mm thick cover of RCC (1:2:4) reinforced with XPM (weight not less than 4 KG/Sqm) and frame of angle iron 25 X 25 X 3mm with lugs 2 Nos and with 6mm dia MS bar handle made to shape, GI medium grade 20mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge plate, common salt and charcoal filling, connecting to test pointwith fixing arrangement, funnel, wire mesh and earth work in hard/dense soil,returning filling in and removal of surplus soil to a distance not exeeding 50 mtr, all as per electrical plate No 3all as specified and testing on completion. Note :- Cost of earth lead upto 7.5 mtr and GI 15mm bore pipe is deemed to be included in unit rate. 34 Supply, installation, testing and commissioning of factory made, DG disribution cum DG syncronization panel of suitable size, outdoor type made out of CRCA sheet 3.15 mm thick with partition of 1.6 mm, frame factory fabricated with front and back openable double door with locking arrangement, with MS angle section 50x50x6 mm support, duly powder coated painting having thickness not less than 100 microns provided suitable gasket to make it dust and vermin proof, suitable for 3 Phase4 wire, 415 Volts, 50 Hz, AC supply system,comprising of following :- (a)Distribution panel with ACB 2500Amp microprocessor release operation type, 415 Volt 50 KA 1 Nos 2500 Amp ACB (b) DG Synchronizing panel- DG Sync Panel with double busbars required for sync 3 nos 400 KVA DG set after Sync Power fed to 2500 Amp Distribution Panel (c)Control Ckt require for DG Sync With PV System, Logic of this control ckt : DG 1, 400 KVA on all time with minimum 30% load and when load increase 80% DG2 400 KVAstart and so on for all 3rd Nos 400 KVA DG) Note: DG syncronization panel shall be provided as per approved SLDcomplete all as specified and directed.. 35 Supply, laying, testing and commissioning of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1.9/3.3 KVgrade, cross-sectional area 400 Sqmm 3 core for solar ACB panel to inverter duty transformercomplete all as specified and directed. 36 Supply and fixing of cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination cold shrinkable type joint complete with jointing meterial and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size400 Sqmmcomplete all as specified and directed. 37 Supply, laying, testing and commissioning of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 400 Sqmm 3.5 corecomplete all as specified and directed. 38 Material and Labourfor Sand cushing to under ground cable, provided with 8 cms thick layer before laying the cable and 15 cm thick after laying and streching the calbe complete all as specified and directed. 39 Supply and laying unreinforced precast concrete cable cover on the cable in the trench,classl LV, Type-I, flat size 250mm X150mmX50mm(1100 volts LT cable)complete all as specified and directed. 40 Supply and laying Unreinforced precastconcrete cable coveron the cable in the trench , class HV, Type-I, flat size 300mm X180mmX50mm (for 11KV HT cable)complete all as specified and directed. 41 Material and Labour for Solar HT Generation meter AC three phase, multifunction net meter of accuracy class 0.5s, rated voltage 110 V Ph-Ph or 3 X 63.5 V Ph-N, voltage range + 15% to - 30% of rated voltage, basic current 1 Amps or 5 Amps, maximum continuous current 2 times (200%) of basic current , starting current 0.1% of basic current, frequency 50 Hz and operating frequency range 47.5 to 50.5 Hz , IP 65 protection, Protection: over voltage, over current, over/ under grid frequency, over temperature, short circuit. with optical & RS232 port, backlit LCD display, (measures import kWh, kVAh, Export kWh, kVAh , Net kWh, kVAh, V,I, kW, 6 month history of energy, load survey, tamper detection & logging, power On/Off events, instantaneous parameters of rating -/5A with display in absence of powercomplete all as specified and directed. 42 Shifting of DG set of capacity 3 x 400 KVA from location Upper and lower chumathang (Upto 2 Km) near to SPV plant location with all connected items including installation, connection with cable, making of suitable size as per existing 3 Nos PCC plateform of 400 KVA DG set all as per specified and directed 43 Supply, laying, testing and commissioning of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 630 Sqmm 3.5 corecomplete all as specified and directed. 44 Material and Labour for Rolling and consolidation formation surface in cuttingto required camber and gradient with 8 to 12 tonne power roller complete all as specified and directed. 45 Material and Labour for soiling (or Sub Base) 200mm thick (Spread thickness) with broken boulders or quarred stone interstices filled, surface formed and surface formed and rolled and consolidated torequired gradient and camber with 8 to 12 tonne power roller, complete all as specified and directed. 46 Material and Labour for cement concrete work in pavement/hardstanding of flexural strength 40 kg/sqcm in field using 400 kg of cement per Cum for thickness of concrete 20 cm including brooming the surface complete all as specified and directed. 47 Material and Labour for forming contraction (Dummy) joints 80mm deepx 10mm wide filled with sealing compound grade B complete all as specified and directed. 48 Material and Labour for forming 20mm thick expansiion joints filled with preformed bituminous filler and top 30mm primed and sealed with sealing compound grade B for 200mm thickness of concrete slab complete all as specified and directed. 49 Material and Labour for 150mm thick (compacted thickness) WMM in two equal layers 75mm thick each layer with coarse aggregates of lime stone, sand stone flint or quartizite of grading 2 (63 to 40mm size) spread, rolled and consolidated to required gradient and camber with 8 to 12 tonne power roller complete all as specified and directed. 50 Material and Labour for Cement concrete 1:3:6 type C-2 using 40 mm graded crushed stone aggregate as in foundation filling and mass concretecomplete all as specified and directed. 51 Material and Labour for Cement concrete 1:2:4 type B-1 using 20 mm graded crushed stone aggregate as in benching, coping around poles (aove GL) etc including weathering slightly rounded or chamfered angles and fair finshing the exposed surfaces or concrete using extra cement cmplete including necessary form workcomplete all as specified and directed. 52 Supplying, installation, commissioning and testing of transformer step down 11/0.415KV capacity750 KVA, Level II, IS 1180 Part I, out door type copper wound 3 phase, 4 wire, 50 cycles per second, oil immersed naturally cooled external cooling tube core type delta connection on primary side (HV side) and star connection on secondary side (LV side) having tapping 0,± 2.5%, ±5%, ±7.5% to be charged by means of hand operated, off load/tap changing gear including first filling of new transformer oil of dielectric strength not less than 60 KV with standard fittings such as two earting terminals for body and one additional for neutral brought out inbushing, oil level gauge indicator for level minimum and maximum, lifting lugs, rating and termina plate, plain breather device to prevent ingress of rain water and inserts, drain cum sampling valve 20mm bore steel with plug,dial type thermo meter, oil filling hole 32mm threaded with plug. The transformer shall be powder coated for water/dust and vermin proof. Note :- (1) Transformer oil shall be conforming to requirements of IS-335-1983 specification for newinsulating oil for transformers.(2) Equipment shall be suitable to operate at 4200 mtr above MSL at temperature variation between -35˚C to (+)35˚ C including platform as per OEM recommendation is deemed to be included in quoted rates (For lower Chumathang) 53 Supplying, installation, commissioning and testing of transformer step down 11/0.415KV capacity400 KVA,Level II, IS 1180 Part I, out door type copper wound 3 phase, 4 wire, 50 cycles per second, oil immersed naturally cooled external cooling tube core type delta connection on primary side (HV side) and star connection on secondary side (LV side) having tapping 0,± 2.5%, ±5%, ±7.5% to be charged by means of hand operated, off load/tap changing gear including first filling of new transformer oil of dielectric strength not less than 60 KV with standard fittings such as two earting terminals for body and one additional for neutral brought out inbushing, oil level gauge indicator for level minimum and maximum, lifting lugs, rating and termina plate, plain breather device to prevent ingress of rain water and inserts, drain cum sampling valve 20mm bore steel with plug,dial type thermo meter, oil filling hole 32mm threaded with plug. The transformer shall be powder coated for water/dust and vermin proof. Note :- (1) Transformer oil shall be conforming to requirements of IS-335-1983 specification for newinsulating oil for transformers.(2) Equipment shall be suitable to operate at 4200 mtr above MSL at temperature variation between -35˚C to (+)35˚ Cincluding platform as per OEM recommendationis deemed to be included in quoted rates (For additional pocket & Upper chumathang)complete all as specified and directed. 54 Material and Labour for Steel tublar swaged poles erected truly vertical or planted as strut complete with 6 mm thick mild steel base plate, welded to pole, B-118 final taper cap,bolts,nuts & screws, poles made out of ERW MS tubing conforming to IS 2713 Part-II. Type 410-SP-55 (11 m long) including drilling of holes of required size for fixing of cross arms, paintin g the exposed surfacs of pole with two coats of aluminium paint over a coat of two coats of zinc chrome3 primer and two coats of black bitumenous paint internally & portion embadded in concrete, making five black & white bands at lower portion of pole each 300 mm wide alternatley, and marking pole No. with black paint at suitable height complete all as specified and directed.(For two/ four pole structure) Note :- Excavation and earth work, PCC in foundation shall be measured and paid for separetely.complete all as specified and directed. 55 Material and Labour for Switch air break gang opertated tripple pole mechanically operated from ground level mounted, outdoor type suitable for vertical instatllation single break provided with locking arrangement for operating handle with lock consisting of mild steel channelHT post top insulator copper alloy high pressure assembly 33 KV grade complete with all accessoriescomplete all as specified and directed. 56 Supply & fixing lightning arrestor, high tension, polymer type gapless complete with all fitting transmission class, of capacity 33 kilo voltscomplete all as specified and directed. 57 Material and Labour forCross arms, bracing , supports, clamps and aback plates ,fabricated out of structural steel sections incuding nuts, bolts,washers,welding,bending cold or hot, drilling holes for bolts in any shape or size as indicated or coat of red oxide zinx chrome primer, one under coat and one finshing coat of aluminium paint complete all as specified. 58 Supply, laying, testing and commissioning of aluminium conductor, XLPE insulated, PVC inner sheathed, GI strip or wire armoured & overall PVC sheathed cable of 11 KV (Earthed) grade in trenchesl/ in GI pipe including dressing and clamping the cable with MS clamps of cross section area 185 Sqmm 3 corecomplete all as specified and directed. 59 Supply, laying, testing and commissioning of aluminium conductor, XLPE insulated, PVC inner sheathed, GI strip or wire armoured & overall PVC sheathed cable of 11 KV (Earthed) grade in trenchesl/ in GI pipe including dressing and clamping the cable with MS clamps of cross section area 120 Sqmm 3 corecomplete all as specified and directed. 60 Supply and fixing of cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination cold shrinkable type joint complete with jointing meterial and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size120 sqmm to 185 sqmmcompleted all as specified and directed. 61 Material and Labour for ACSR conductor for the provision of HT OH lineof sizes,3 of 6/1X3.0 (Ferret), 3 of 6/ 1x2.59 ( weasel) completed all as specified and directed. 62 Material and Labour for galvanised steel wire of4 mm dia with hooks stretching kinks and bends completed all as specified and directed. 63 Anticlimbing devices spikes type fabricated out of MS bars (round square and flat) including nuts, bolts, washers and welding in two halves made to shape to suit the cross section of the pole complete all as specified and shown on drawings. 64 Supply and fixing pin type 10 KN polymer type, porcelain, viterous white, brown or green insulator including one mild steel spindle,for 33000 volts grade incl all accessories for fixing of pin insulator completed all as specified and directed. 65 Supply and fixing disc type 90 KN polymer type, porcelain, viterous white, brown or green insulator including one mild steel spindle,for 33000 volts grade incl all accessories for fixing of disc insulator completed all as specified and directed. 66 Supply and fixing of Danger notice plate of 1.6 mm thick mild steel sheet, vitreous enamelled white, with letter, figures and conventional skull and bones in signal red colour and fixed with M.S clamps, bolts and nuts of approved size, for HT,25x20cm sizecomplete all as specified and directed. 67 Material and Labour for Galvanised steel tubing light grade 80 mm bore laid in trenches orfix to wall/hole with fitting as required for cable protectioncomplete all as specified and directed. 68 Material and Labour for Galvanised steel tubing light grade 100 mm bore laid in trenches orfix to wall/hole with fitting as required for cable protectioncomplete all as specified and directed. 69 Material and Labour for stay assembly complete using stay rod of 20 mm dia complete with accessories as shown in electric plate no 1 of SSR-2009 Part -I complete all as specified and directed by Engr-in-Charge Note: (Unit rate quoted by contractor herein before also includes earth work and PCC work ,Loop type insulator ,stay clamps ,nuts ,bolts ,washers and concretecomplete all as specified and directed. 70 Material and Labour for galvanised stay strand, size 7/4 mmcomplete all as specified and directed. 71 Supply and fixing of loop type porcelain vitreous white ,brown or green insulator large size with overall dimensions 90x140 mm,clearance of hole 25.5 mm complete all as specified and directed 72 Supply and install LT panel outdoor type weather & vermin proofsuitable for 3 phase 415 V made out of 3.15 mm thick MS sheet duly powder coatedand both sides openable with lockingarrangment and aluminium busbar of capacity not less than 2200 Amp insulated with PVC sleeves and coloured with (R,Y,B and Black) with angle iron frame for stand made out of40 x 40 x 6mmincludingfour legs grouted by using PCC (1:2:4) type B 1 with 20mm graded stone aggregate thimbling andcable entry box incl connection and necessary fixing arrangement complete all as specified anddirected by Engineer in Charge. 73 Under composion of following.(LT panel No-01 Lower Chumathag)(i)ACB 415 V, 4 pole, 1600 Amp, 50 KA -01 No (Incoming)(ii) ACB 415 V, 4 pole, 800 Amp, 50 KA -01 No (Outgoing)For existing DG panel (iii) ACB 415 V, 4 pole, 800 Amp, 50 KA -01 No (Outgoing)For existing DG panel(iv) Bus bar chamber with and including aluminium strip (set 4 Nos) suitable for 2500 Amps duly moounted on porcelain insulators -01 Set (v) Digital amp meter 3 ph programmeable type with suitable2500 Amps -01 Set (vi)Digital volt meter 3 ph programmeable type with suitable0- 500 volts -01 Set (vii) LED phase indicator (RYB )-01 Set 74 Supply and install LT panel outdoor type weather & vermin proofsuitable for 3 phase 415 V made out of 3.15 mm thick MS sheet duly powder coatedand both sides openable with lockingarrangment and copper busbar of capacity not less than 1250 Amp insulated with PVC sleeves and coloured with (R,Y,B and Black) with angle iron frame for stand made out of40 x 40 x 6mmincludingfour legs grouted by using PCC (1:2:4) type B 1 with 20mm graded stone aggregate thimbling andcable entry box incl connection and necessary fixing arrangement complete all as specified anddirected by Engineer in Charge. 75 Under composion of following. (LT Panel No-2 upper chumathang)(i)ACB 415 V, 4 pole, 800 Amp, 50 KA -01 No (Incoming cum outgoing) (ii) Bus bar chamber with and including aluminium strip (set 4 Nos) suitable for 1200 Amps duly moounted on porcelain insulators -01 Set(iv) Digital amp meter 3 ph programmeable type with suitable 800 Amps -01 Set(v)Digital volt meter 3 ph programmeable type with suitable 0-500 volts -01 Set (vi) LED phase indicator (RYB )-01 Set 76 Supply and install LT panel outdoor type weather & vermin proofsuitable for 3 phase 415 V made out of 3.15 mm thick MS sheet duly powder coatedand both sides openable with lockingarrangment and copper busbar of capacity not less than 1250 Amp insulated with PVC sleeves and coloured with (R,Y,B and Black) with angle iron frame for stand made out of40 x 40 x 6mmincludingfour legs grouted by using PCC (1:2:4) type B 1 with 20mm graded stone aggregate thimbling andcable entry box incl connection and necessary fixing arrangement complete all as specified anddirected by Engineer in Charge. Under composion of following. (LT Panel No-3 upper chumathang additional pocket) 77 (i)ACB 415 V, 4 pole, 800 Amp, 50 KA -01 No (Incoming)(ii) MCCB 415 V, 4 pole, 200 Amp, 25 KA -1 No (Out Going), MCCB 415 V, 4 pole, 400 Amp, 36 KA -1 No (Out Going) MCCB 415 V, 4 pole, 100 Amp, 25 KA -1 No (Out Going)(iii) Bus bar chamber with and including aluminium strip (set 4 Nos) suitable for 1250 Amps duly moounted on porcelain insulators -01 Set (iv) Digital amp meter 3 ph programmeable type with suitable 800 Amps -01 Set (v)Digital volt meter 3 ph programmeable type with suitable 0-500 volts -01 Set (vi) LED phase indicator (RYB )-01 Set 78 Supply, laying, testing and commissioning of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 300 Sqmm 3.5 core complete all as specified anddirected 79 Supply, laying, testing and commissioning of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 240 Sqmm 3.5 core complete all as specified anddirected 80 Supply, laying, testing and commissioning of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 185 Sqmm 3.5 core complete all as specified anddirected 81 Supply, laying, testing and commissioning of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 10 Sqmm 2 core complete all as specified anddirected 82 Supply and fixing of LED Street light of 70 Watt , IP66 power coated pressure die cast aluminium housing with high efficiency LED as lighting source and toughened glass complete all as specified anddirected 83 Supply and install LT panel box outdoor type weather & vermin proofsuitable for single phase 230 V made out of 3.15 mm thick MS sheet duly powder coatedand both sides openable with lockingarrangment and aluminium busbar of capacity not less than 100 Amp insulated with phase indicator incl angle iron frame for stand made out of40 x 40 x 6mmincludingfour legs grouted by using PCC (1:2:4) type B 1 with 20mm graded stone aggregate thimbling andcable entry box incl connection and necessary fixing arrangement complete all as specified anddirected by Engineer in Charge. Under composion of following.(For Street light)(i) MCB SPN 6-32 Amps, 230V, 10 KA -01 No (Incoming)(ii) MCB SP 6-10 Amps, 230V, 10 KA -02 No (outcoming)(iii) Bus bar chamber with and including aluminium strip ( 2 Nos) suitable for 100 Amps duly moounted on porcelain insulators -01 Set (iv) LED phase indicator (RYB )-01 Set 84 Supply and fixing GI bracket 1.2 m long made out of GI pipe 40mm dia mediam grade with necessary clamp for fixing nut and bolts and connection complete all as specified anddirected 85 Material and Labour for Steel tublar swaged poles erected truly vertical or planted as strut complete with 6 mm thick mild steel base plate, welded to pole, B-118 final taper cap,bolts,nuts & screws, poles made out of ERW MS tubing conforming to IS 2713 Part-II. Type 410-SP-31 (09 m long) including drilling of holes of required size for fixing of cross arms, paintin g the exposed surfacs of pole with two coats of aluminium paint over a coat of two coats of zinc chrome3 primer and two coats of black bitumenous paint internally & portion embadded in concrete, making five black & white bands at lower portion of pole each 300 mm wide alternatley, and marking pole No. with black paint at suitable height complete all as specified and directed.Note :- Excavation and earth work, PCC in foundation shall be measured and paid for separetely. 86 Supply and fixing of 2.5 sqmm copper conductor cable for street light connection from junction box to street light at pole all as specified and directed by Engr-in-charge 87 Supply and fixing of junction box made out of PVC box with necessary clamps for fixing busbar with MCB SP 6 Amps and necessary connection from street light to junction box with 2.5 sqmm x 3C copper conductor cable complete all as specified anddirected 88 Material and Labour for Plain cement concrete 1:3:6 type C-2 (using 40mm graded crushed stone aggregate) as in bed to drain pipes including packing under and haunching completely surrounding pipes with concrete after they laid and tested for 150 mm bore NP 2 pipe, complete all as specified and directed. 89 Material and Labour forM&L for Reinforced concrete pipes,class NP2,dia 150 mmlaid and jointed complete with collars complete all as specified and directed. 90 Material and Labour for PCC 1:2:4 Type B1 using 20 mm garded stone agg as in coping including weathering slightly rounded or chamfered angles and throating complete all as specified and directed. 91 Supply onlyliquid water proofing compoundcomplete all as specified and directed. 92 Material and Labour forTMT bars 10mm dia and over , cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed not less than 0.9mm dia, or securing with clips, rungs, handles completeall as specified and directed. 93 Material and Labour forprecast cement concrete 1:2:4 type B-1 using 20mm graded crushed stone aggregates as in manhole coverslabsincluding necessary formworks set in cement mortar 1:4 complete all as specified and directed. 94 Material and Labour for cement concrete 1:3:6 type C-1 using 20mm graded crushed stone aggregate as in surface channel and inside drains of manhole complete all as specified and directed. 95 Material and Labour for Mild steel rungs and handle made to shape out of 16mm dia round barsconforming to Fe-290grade E-165including fixing/embedding in concrete /masonrypainted with two coats of bituminous paint complete all as specified and directed. 96 Extra forming fair finished drain or channel 30cm inner girth in cement concrete using extra cement including forms moulds mitred/stopped ends etc complete all as specified and directed. 97 Use and waste of formwork to soffits of suspended slabs such as roof slabs, floor slabs, landing and similar work not exc 200mm thick (horizontal or sloping) for flat fair finished surfaces complete all as specified and directed. 98 Material and Labour for construction of septic tank for 10 users designed to carry sewage and sewage water, excavation in any type of soil, PCC 1:2:4 type B-2 using 40mm graded crushed stone aggregates in foundation, precast cement concrete block masonry wall, RCC cover slab complete all as specified and directed and shown on drawing. 99 Material and Labour for construction of soakage well with excavation in any type of soil complete all as specifiedand directed and shown on drawing. 100 Material and Labour for MS work as in posts and struts posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed. 101 Supply only chain link MS galvanised fencing any size or type complete all as specified anddirectedNote : weight of chain link fencing shall be checked by BOO detailed by GE. 102 Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards rails straining bolts etc including provision of binding wire complete all as specified and directed. 103 Material and Labour for prepration of new or previously untreated steel surface & priming with red oxide primer and applying two coats of synthetic enamel paint of any description over 10cm width or girth not otherwise described complete all as specified and directed. 104 Material and Labour for PCC 1:2:4 type B-1 using 20mm graded crushed stone aggregate Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed. 105 Material and Labour for Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n exc 22.5cm longand diameter of neck 11 to 15mm complete all as specified and directed. 106 Material and Labour for construction of steel gate 5.5m wide and 3m high with RCC pillars including excavation and earth work and all other relevant works complete all as specified and directed. 107 Excavation over area not exc 1.5m deep and getting out in hard/dense soil complete all as specified and directed. 108 Excavation in trenches, n exc 1.5 mtr wide and n exc 1.5 mtr in depth for foundation etc. or for shafts, wells, cesspits, manholes, pier holes etc. n exc 10 Sqm on plan and n exc 1.5 mtr in depth and getting out inhard/dense soil. Complete all specifed and directed. 109 All as per Srl No. 94. above but exc 1.5 m or part there ofin depth beyond the first 1.5m complete all as specified anddirected 110 Excavation in post holes (or similar holes) each not exc 0.5 Cum getting out returning filling and ramming earth or broken rubble mixed with earth around in layers not exc 25cm watering and removing surplus soil to a distance not exc 50 and making good surface in hard/dense soil complete all as specified and directed. 111 Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed . 112 Removing excavated material (soil) to a distance not exc 50m and depositing where directed at a level not exc 1.5m above the starting point complete all as specified and directed. 113 Removing excavated rocks material from site n exc. 50 m and depositing where directed at a level n exc. 1.5m above the starting point complete all as specified anddirected
Contract Date: Jun 20, 2026 Contract Value : 6.14 Crore
Statutory Bodies & Commissions/Committees No of Bidders 9
5.
Heavy Industries and Public Enterprises #10390733 AOC
Vertical Extension & Other Development Works at Academic Block Annex-2 Palayad Campus, Kannur University, Kannur, Kerala under PM-USHA scheme- 1 Civil work -General Structural work 2 Chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual Chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of Engineer-In-Charge25 mm average thickness 3 Cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per direction of Engineer-In-Charge.Bars upto 12 mm diameter 4 Demolishing R.C.C. work manually / by mechanical means including stacking of steel bars and disposal of unserviceable material with in 50 metres lead as per direction of Engineer -in-Charge. 5 Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge.In cement mortar 6 Core Cutting of RCC slabs(12cm Maxi.thickness) by using mechanical core cutting equipment of required diameter of the pipe in full depth etc to the satisfaction of engineer in charge including all cost and conveyance materials and labours charge etc complete (dia 80-200mm) 7 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil 8 Extra for cutting reinforcement bars manually/ by mechanical means in R.C.C. or R.B. work ( Payment shall be made on the cross sectional area of R.C.C. or R.B work) as per direction of Engineer-in-charge. 9 Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil. and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within alead of 50 m:Pipes, cables etc. exceeding 80 mm dia but not exceeding 300 mm dia 10 Excavation work by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50 m.Ordinary rock 11 Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. 12 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size) 13 Providing and laying cement concrete in retaining walls, return walls, walls ( any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts,buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor, etc. up to floor five level, excluding the cost of centering, shuttering and finishing:1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) 14 Making plinth protection 50 mm thick of cement concrete 1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75 mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the top smooth. 15 Providing and laying in position machine batched and machine mixed design mix M- 25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to siteof laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work above plinth level upto floor V level 16 Extra for providing richer mixes at all floor levels. Note:- Excess/less cement over the specified cement content used is payable/ recoverable separately.Providing M-30 grade concrete instead of M-25 grade BMC/RMC. (Note:- Cement content considered in M-30 is @ 340 kg/cum). 17 Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. 18 Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform 19 Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers 20 Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts 21 Centering and shuttering including strutting, etc. and removal of form for:Stairs, (excluding landings ) except spiral - staircases) 22 Centering and shuttering including strutting, etc. and removal of form for:Weather shade, Chajjas, corbels etc., including edges 23 Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders, bressumers and cantilevers with water proof ply 12 mm thick. 24 Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo - Mechanically Treated bars of grade Fe-500D or more 25 Block work & Finishing Work 26 Laterate masonry with neatly dressed laterate stone of size 40x20x15cm or nearest size in cement mortar 1:6 for super structure above plinth level up to floor two level including all cost of materials, labour charges etc. 27 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) 28 6 mm cement plaster of mix:1:3 ( 1 cement : 3 fine sand) 29 Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer 30 12 mm cement plaster finished with a floating coat of neat cement of mix:1:3 ( 1 cement : 3 fine sand) 31 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 32 Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile including applying additional coats wherever required to achieve even shade and colour.Two coats 33 Finishing walls with Acrylic Smooth exterior paint of required shade:New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) 34 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work 35 Add for plaster drip course / groove in plastered surface or moulding to R.C.C. projections. 36 Teracotta Clay Jali work, For Building work, minimum 7.5 cm thick as per approved design and pattern of Engineer in charge in super structure above plinth level upto floor V level with cement mortar 1:4 (1 cement : 4 coarse sand) with neat finish, polishing work all complete. 37 Providing and fixing partition upto ceiling height consisting of G.I. frame and required board, including providing and fixing of frame work made of special section power pressed/ roll form G.I. sheet with Zinc coating of 120 gms/ (both side inclusive), consisting of floor and ceiling channel 50 mm wide having equal flanges of 32 mm and 0.50 mm thick, fixed to the floor and ceiling at the spacing of 610 mm centre to centre with dash fastener of 12.5 mm dia meter 50 mm length or suitable anchor fastener or metal screws with nylon plugs and the studs 48 mm wide having one flange of 34 mm and other flange 36 mm and 0.50 mm thick fixed vertically within flanges of floor and ceiling channel and placed at a spacing of 610 mm centre to centre by 6 mm dia bolts and nuts, including fixing of studs along both ends of partition fixed flush to wallwith suitable anchor fastener or metal screws with nylon plugs at spacing of 450 mm centre to centre, and fixing of boards to both side of frame work by 25 mm long dry wall screws on studs, floor and ceiling channels at the spacing of 300 mm centre to centre.The boards are to be fixed to the frame work with joints staggered to avoid through cracks, M.S. fixing channelof 99 mm width (0.9 mm thick having two flanges of 9.5 mm each) to be provided at the horizontal joints of two boards, fixed to the studs using metal to metal flat head screws, including jointing and finishing to a flush finish with recommended jointing compound, jointing tape, angle beads at corners (25 mm x 25 mm x0.5 mm), joint finisher and two coats of primer suitable for board as per manufactures specification and direction of engineer in charge all complete.75 mm overall thickness partition with 12.5 mm thick double skin fire rated Glass Reinforced Gypsum (GRG),plaster board conforming to IS : 2095 : (part 3) 1996 (Board with BIS Certification marks) 38 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions,i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately):For fixed portionPowder coated aluminium (minimum thickness of powder coating 50 micron) 39 For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately)Powder coated aluminium (minimum thickness of powder coating 50 micron) 40 Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS : 12823 Grade I Type II, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of Engineer - in- Charge.Pre- laminated particle board with decorative lamination on both sides 41 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness 42 Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete:125 mm 43 Providing and fixing bright finished 100 mm mortice lock with 6 levers without pair of handles of approved quality for aluminium door, with necessary screws etc complete as per direction of Engineer- in- charge. 44 Providing and fixing aluminium tower bolts, ISI marked, anodised(anodic coating not less than grade AC 10 as per : 1868), transparent or dyed to required colour or shade, with necessary screws complete:300x10 mm 45 Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. 46 Joinery 47 Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross- section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminated shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2 mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame. 48 Providing and fixing to existing door frames.30 mm thick Fiberglass Reinforced Plastic (F.R.P) flush door shutter in different plain and wood finish made with fire retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate all around, with suitable wooden blocks inside at required places for fixing of fittings and polyurethane foam (PUF) / Polystyrene foam to be used all filler material throughout the hollow panel, casted monoolithically with testing parameters of F.R.P. laminate conforming to table - 3 of IS : 14856, complete as per direction of Engineer- in-charge. 49 Providing and fixing factory made uPVC white colour casement/casement cum fixedglazedwindowscomprisingofuPVCmulti-chamberedframe,sashand mullion(whereeverrequired)extrudedprofilesduly reinforcedwith1.60+/- 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriatedimension,EPDMgasket,stainlesssteel(SS304grade)friction hinges, zinc alloy (white powder coated) casement handles, G.I fasteners 100 x 8 mmsizeforfixingframetofinishedwall,plasticpackers,plasticcapsand necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardwares and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately)Note: For uPVC frame, sash and mullion extruded profilesminus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable.Casement window double panels with S.S. friction hinges (350 x 19 x 1.9 mm) made of (big series) frame 67 x 60 mm & sash / mullion 67 x 80 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead/ double glazing bead of appropriate dimension. (Area of window above 1.50 sqm). 50 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5.50 mm thickness 51 Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately), using good quality Anjili wood /jack wood 52 Providing and fixing paneled and glazed shutters for doors, windows and clerestory windows, 35 mm thick shutters including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineerin - charge using Anjili/ Jack wood 53 Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to openings/ wooden frames with rawl plugs screws etc 54 Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embeddings in cement concrete block 30x10x15 cm 1:3:6 mix ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) 55 Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete:250x10 mm 56 Providing and fixing CP Brass Handle 450mm in all types of doors with the necessary fittings and arrangements all complete. 57 Providingand fixing chromium plated brass handles with necessary screws etc. complete:200 mm 58 Providing and fixing bright finished 100 mm mortice lock with 6 levers without pair of handles of approved quality, with necessary screws etc complete as per direction of Engineer- in- charge. 59 French spirit polishing:Two or more coats on new works including a coat of wood filler 60 Providing and fixing 1 mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer.Using flats 30x6 mm for diagonal braces and central cross piece 61 Fire Metal door. Material Specifications: Frame : GI 1.60 mm, Shutter : GI 1.20 mm, Shutter Width / Active Shutter Width : 808.00 mm, Frame Profile: 143.00 mm X 57.00 mm, Frame Profile type : Normal, Frame Rebate : Double, Door type : Single leaf door, Infill Material : Honey Comb, Vision Panel Active: 200 mmX300 mm. 8nos Ball bearing butt hinge, BB3090F, SS304, of size 100 x 75 x 3mm with screws in SSS , 1no Euro profile half cylinder 3005, 42mm Key x Blank, Silver satin finish , 2no Surface door closer TS73, size EN2/3/4, with standard arm, Silver finish, 1no Clear glass, 6mm of size 200 x 300mm, 2 nos concealed flush bolt, Mortise sash lock with lever handle on side and panic lever on other side. The door should have a minimum fire rating of 2hrs . Wall Opening Size 1800X2250 mm. 62 Fire Metal door. Material Specifications: Frame : GI 1.60 mm, Shutter : GI 1.20 mm, Shutter Width / Active Shutter Width : 808.00 mm, Frame Profile: 143.00 mm X 57.00 mm, Frame Profile type : Normal, Frame Rebate : Double, Door type : Single leaf door, Infill Material : Honey Comb, Vision Panel Active: 200 mmX300 mm. 8nos Ball bearing butt hinge, BB3090F, SS304, of size 100 x 75 x 3mm with screws in SSS , 1no Euro profile half cylinder 3005, 42mm Key x Blank, Silver satin finish , 2no Surface door closer TS73, size EN2/3/4, with standard arm, Silver finish, 1no Clear glass, 6mm of size 200 x 300mm, 2 nos concealed flush bolt, Mortise sash lock with lever handle on side and panic lever on other side. The door should have a minimum fire rating of 2hrs . Wall Opening Size 1000X2200 mm. 63 Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge ( Door handle, lock and stopper etc to be paid separately) 64 Providing and fixing SS H handle having min 45 cm length in toughed glass door including all necessary screws etc. complete. 65 Providing and fixing of glass door SS Patch Lock with out handle in toughened glass door including all necessary screws etc. complete 66 Fixing 12 mm thick frameless toughened glass partition of approved brand and manufacture, including top & bottom fixing arrangement and making necessary holes etc. for fixing required fittings, all complete as per direction of Engineer-in- charge. 67 Providing and fixing 3M Fasara frosted etching film of thickness 25 microns self- adhesive of approved colour, shade, and quality with cutting as per approved design and pattern, including cleaning of glass and making surface smooth for fixing of film to the surface, all completed as per the direction of the engineer in charge. 68 Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.80x1.25 mm M.S. laths with 1.25 mm thick top cover 69 Providing and fixing ball bearing for rolling shutters. 70 Sanitary and CP Fittings 71 Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm Sand Cast Iron P or S trap, 10 litter low level white P.V.C.flushing cistern, including flush pipe, manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever require:White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests 72 Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:W.C. pan with ISI marked white solid plastic seat and lid 73 Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm or 340x410x265 mm sizes respectively. 74 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Flat back wash basin size 450x300 mm with single 15 mm C.P. brass pillar tap 75 Providing and fixing ceramic urinal partitions of standard size as per direction of Engineer-in Charge and of approved shade 76 Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.15 mm nominal bore 77 Providing and fixing uplasticised PVC connectionpipe with brass unions: 30 cm length15 mm nominal bore 78 Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet:150 mm diameter 79 Providing and fixing C.P brass stop cock ( concealed) of standard design and of approved make conforming to IS: 893115 mm nominal bore 80 Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS: 893115 mm nominal bore 81 Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required:Kitchen sink without drain board610x510 mm bowl depth 200 mm 82 Providing and fixing white vitreous china laboratory sink with C.I brackets, C.P. brass chain with rubber plug 40 mm C.P brass waste and 40 mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required:Size 600x450x200 mm 83 Supplying and fixing CP Towel rod 45cm or nearest available length including cost of materials and labour charges etc complete as per the direction of site Engineer-in- charge. 84 Supplying and fixing CP Health faucet good quality including cost of materials and labour charges etc. complete as per the direction of site engineer-in-charge. 85 Flexible pipe32 mm dia 86 Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with C.P. brass screws and washers complete. 87 Supplying and fixing PVC Floor Trap 100mmx75mm size without Jali including cutting open, boring through RCC slabs and making good the damages. 88 Providing and fixing SS grating of approved quality and colour. Rectangular type with openable lid150 mm nominal size square 100 mm diameter of the inner hinged grating. 89 Providing and fixing disabled friendly bathroom kit with all accessories including wash closet with soft close seat cover and cistern with twin flush setting, wash basin of min dimensions 510mm x 400mm with all necessary fittings including Angle cock, Connection pipe, waste pipe, Spatula Lever basin mixer, Wall mounted 600mm long, Wall mounted grab bar 600 mm long and wall mounted hinged rail 750 x 750, Health Faucet with angle cock. Recommended Makes : CERA , Hindware, Jaguar or equivalent . 90 Plumbing 91 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge.Internal work - Exposed on wall32 mm nominal outer dia pipes 92 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge.Internal work - Exposed on wall40 mm nominal outer dia pipes 93 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge.Internal work - Exposed on wall50 mm nominal outer dia pipes 94 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes& fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge.Concealed work, including cutting chases and making good the wall etc.20 mm nominal outer dia pipes 95 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes& fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge.Concealed work, including cutting chases and making good the wall etc.25 mm nominal outer dia pipes 96 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :32 mm nominal bore 97 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :40 mm nominal bore 98 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :50 mm nominal bore 99 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :25 mm nominal bore 100 Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 32 mm dia 10Kgf/cm2- Internal work - Exposed on wall 101 Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 50 mm dia 10 Kfg/cm - Internal work- Exposed on wall 102 Providing and fixing PVC pipes including fixing the pipe with clamps/ clip at 1.00 m spacing . This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 63 mm dia 6 Kgf/cm2 - External work - Exposed on wall 103 Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 63 mm dia Elbow 104 Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes including jointing with PVC solvent cement - 63x63x63 mm dia Tee 105 Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 63x50 mm dia Reducer 106 Supplying and fixing PVC Floor Trap 100mmx75mm size without Jali including cutting open, boring through RCC slabs and making good the damages. 107 Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge.Concealed work, including cutting chases and making good the wall etc. 32 mm pipe 6Kgf/cm2 108 Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge.Concealed work, including cutting chases and making good the wall etc. 40 mm pipe 6Kgf/cm2 109 Providing and fixing PVC pipes including fixing the pipe with clamps/clips at 1.00 m spacing. This included jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 75 mm dia 6Kgf/cm2 - External work- Exposed on wall 110 Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 75 mm dia Bend 111 Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 75x75x75 mm dia Door Tee 112 Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 75 mm dia Vent cowl 113 Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement -75 mm dia End cap 114 Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement -75 mm dia 45 degree Elbow 115 Providing and fixing PVC pipes including fixing the pipe with clamps/ clips/ at 1.00 m spacing . This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 110 mm dia 6 Kgf/cm2 - External work- Exposed on wall 116 Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement- 110 mm dia Bend 117 Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110x110x110 mm dia Door tee 118 Providing and fixing PVC moulded fittings /accessories for Rigid PVC pipes, including jointing with PVC solvent cement -110 mm dia Vent cowl 119 Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement -110 mm dia End Cap 120 Providing and fixing PVC moulded fittings / accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110 mm dia 45 degree Elbow 121 Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110x75 mm dia Reducer 122 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :80 mm nominal bore 123 Providing and placing on terrace (at all floor levels) polyethylene water storage tank:ISI 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 124 Yard Plumbing 125 Providing and fixing PVC pipes includings jointing of pipes with one step pvc solvent cement, trenching , refilling & testing of joints complete as per direction of Engineer in Charge. 150 mm dia 6 Kgf/cm2 126 Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes,including jointing with PVC solvent cement - 110 mm dia Socket/ coupling 127 Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand) with R.C.C. top with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix ( 1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size,) inside plastering 12 mm thick with cement mortar 1:3 ( 1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) finished with a floating coat of neat cement complete as per standard design:Inside size 120x90 cm and 90 cm deep including C.I. cover with frame ( medium duty ) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg ( weight of cover 58 kg and weight of frame 58 kg):With common burnt clay F.P.S ( non modular) bricks of class designation 7.5 128 Providing and fixing on wall face unplasticised- PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion Single pushfit Coupler110 mm 129 Providing and fixing on wall face unplasticised- PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansionBend 87.50110 mm bend 130 Tile and Granite work 131 Providing and laying Matt Finished vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 1200 x 600 mm. 132 Providing and laying Matt finished Vitrified tiles indifferent sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, ofapproved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 1200x600 mm 133 Providing and laying Anti Skid matt vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600 x 600 mm. 134 Providing and laying premium vitrified bathroom wall tile in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete. 135 Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg). including filling /grouting and finishing complete as per direction of Engineer-in-charge.Size of Tile 600x600 mm 136 Marble work gang saw cut (polished and machine cut) of thickness 18 mm for wall lining ( veneer work), backing filled with a grout of 12 mm thick average in cement mortar 1:3 ( 1 cement : 3 coarse sand), including pointing with white cement mortar 1:2 ( 1 white cement : 2 marble dust) with an admixture of pigment to match the marble shade ( To be secured to the backing by means of cramps, which shall be paid for separately).Area of slab over 0.50 sqm 137 Providing and fixing 18 mm thick gang saw cut, mirror, polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 ( 1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Granite of any colour and shade. Area of slab over 0.50 sqm 138 Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent. 139 Providing edge moulding to 18 mm thick marble stone counters, vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer -in-Charge.Granite work 140 Extra for providing opening or required size & shape for wash basin/kitchen sink in kitchen platform, vanity counter and similar location in marble/granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. 141 Providing and laying tactile tile (for vision impaired persons as per standards) of size 300x300x9.8mm having with water absorption less than 0.5% and conforming to IS: 15622 of approved make in all colours and shades in for outdoor floors such as footpath, court yard, multi modals location etc., laid on 20mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as per direction of Engineer-in-Charge. 142 Providing and fixing 12 mm thick gang saw cut, mat /rough finished granite, machine cut for steps, ramps or inclined plate form with raking and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 ( 1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. 143 Structural steel 144 Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) 145 Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. 146 Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. 147 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes 148 Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05%), total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 149 False ceiling 150 Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/ sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37 mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50 mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25 mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5x25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound, jointing tapes, finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturers specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with:12.5 mm thick tapered edge gypsum moisture resistant board 151 Providing and fixing tiled false ceiling of approved materials of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections (galvanized @ 120 grams per sqm, both side inclusive) consisting of main T runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200mm center to center and cross T of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main T at 600 mm center to center to form a grid of 1200x600 mm and secondary cross T of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main T runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x 1.6 mm fixed to ceiling with 12.5mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85x 30x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T- sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer -in-charge.12.5 mm thick square edge PVC Laminated Gypsum Tile size 595x595 mm made of Gypsum plasterboard , manufactured from natural gypsum as per IS 2095 part I and laminated with white 0.16 mm thick fire retardant PVC film on the face side and 12 micron metalized polyster on the back side with all edges sealed with the face side PVC film which goes around and wraps the edges and is bonded to the edges and the back side metalized polyster film so as to make the tile a completely sealed unit. 152 Rainwater Harvesting ,Fire Tank,Septic Tank 153 Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.Ordinary rock 154 Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.Ordinary or hard rock 155 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. 156 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size) 157 Providing and laying in position machine batched and machine mixed design mix M- 25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to siteof laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work upto plinth level 158 Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more 159 Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels/ subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineerin-charge. The product performance shall carry guarantee for 10 years against any leakage.For vertical surface two coats @0.70 kg per sqm 160 Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels/ subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineerin-charge. The product performance shall carry guarantee for 10 years against any leakage.For horizontal surface one coat @1.10 kg per sqm. 161 Supplying and fixing C.I with frame for manholes: 600mm x 600mm ( heavy duty) the weight of the cover and frame shall not be less than 208 kg 162 Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of Joints complete as per direction of engineer in charge.110 mm dia 6Kgf/cm2 163 Providing and placing on terrace (at all floor levels) Stainless Steel 304as per IS 5522:1992 of capacity 5000 Litreswith suitable fixing arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 164 Providing and fixing of Fire Rated door 1200x2100mm- Hollow metal fire doors at all levels from ISO 9001-2015 certified Manufacturer. Fire door should be as per NFPA 80 and NFPA 252. All fire doors should be tested at UL for 120 minutes and should pass both UL10B and UL10C. Doors shall be made from pressed galvanized steel confirming to IS277 as per following specification.Frame:Door frame shall be single rebate grooved profile of size 125 x 55 mm made out of 1.6 mm (16 gauge) minimum thick galvanized steel sheet. Frames shall be mitered and field assembled with self-tabs. Frames to have in build grooved sealing system and shall be site fitted with fire rated EPDM gasket as standard. All provision should be mortised, drilled and tapped for receiving appropriate ANSI UL labeled hardware. Frames should be provided with back plate bracket and anchor fasteners for installation on a finished plastered masonry wall opening. Frames shall be filled with fire rated puff and the gaps shall be sealed with silicon sealant.Shutter: Door leaf shall be 46 mm thick fully flush double skin door without vision lite. Door leaf shall be manufactured from 1.2 mm (18 gauge) minimum thick galvanized steel sheet.The infill material shall be resin bonded honeycomb core. All doors should be factory prepped for receiving appropriate hardware and provided with necessary reinforcement for hinges, locks, and door closers as per ANSI standard. For pair of doors integrated astragals has to be provided on the meeting stile for both active and inactive leaf.Door and frames shall be finished Pure Polyester Powder coated and shall have passed minimum 500 hours of salt spray test.Vision glass: The glass shall be 5mm clear fire rated glass of equal rating and not exceeding size of 114 sq. inches.Door Hardware: Stainless steel Ball bearing Hinges 3 Nos, Minimum 90Kg hydraulic surface applied rack and pinion door closers, Mortice Sash Lock with cylinder. One Side Handle and Other Side with 2 point Panic Bar. 165 Road Work 166 Construction of granular sub- base by Providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, Carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in- Charge.With Material conforming to Grade - I ( size range 75 mm to 0.075 mm) having CBR Value- 30 167 Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge.80 mm thick C.C. paver block of M-30 grade with approved color design and pattern. 168 Water proofing 169 Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg /sqm mixed with water proofing cement compound @ 0.126 kg/ sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. 170 Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying : a) after surface preparation, first layer of slurry of cement @ 0.488 kg/ sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. laying second layer of fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm. c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/ sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around. d) fourth and final layer of brick tilling with cement mortar (which will be paid for separately. For the purpose of measurement the entire treated surface will be measured) 171 Landscaping 172 Supplying of Flowering Shrubs (Heliconiya st. Vincent red, Ixora bush, Cana durf etc..) 173 Plantation of Trees, Shrubs, and Hedge at site i/c watering and removalof unsaverieable material?s as per direction of officer in charge (including cast of plant & water )Cost of plantation per trees plants (for 100 nos.=427.45/100) 174 Providing and Laying Landscaping of outdoor area with buffalo grass and small plants with all necessary levelling and filling as required. 175 Signage 176 Providing and fixing in position the signage board made out of 3 mm opaque PVC foam board of computerised cut, PVC non reflective self adhesive vinyl painted foam board of required size and colour. 177 Providing and fixing non lit Signages made of CNC Cut Stainless Steel projected letters and fixing it at site with all necessary fitting arrangements and accessories as per the design and requirement on instructions of the engineer in charge. 178 Furniture 179 Two tiered reagent racks (MS with powder coating) with granite top of 150 mm depth for side workbenches. The two tier should be placed at a minimum spacing of 300 mm. The item should be in compliance with IS 4209 (2013), NABL etc. The Length should be customized as per lab workbench and vertical posts must be placed at appropriate spacing. 180 Supply and Installation of Sink Module with SinkEach sink module should have a minimum dimension of 900 mm (L) x 900 mm (W) x 900 mm (H) and made of MS as per IS 1730 shall be designed with a single cabinet (with 2 shutter, SS304 hinges for easy and noiseless opening and closing mechanism). This module should include a sink made of 5 mm thick polypropylene with black color body. Minimum Dimension of the sink: 450 mm (L) x 600 mm (W). Sink should include PVC tap connection-15mm diameter (Goose neck type), grating etc. The sink module shall be portable and provided with 18mm thick granite table top (with cut out for providing sink). Item to be inclusive of all necessary fitting arrangement.The item should be in compliance with IS 4209 (2013), NABL, WHO etc. 181 Supplying and Fixing of Lab work Table with Granite Top supported over 18mm thick marine plywood , frame work with with GI members with Heavy Duty Levelers, minimum dimension of 2000mm L x 750 mm D 182 Supplying and Fixing of Lab work Table with Granite Top supported over 18mm thick marine plywood , frame work with with GI members with Heavy Duty Levelers, minimum dimension of 2000mm L x 890mm D 183 Supply, Installation, Testing and Commissioning of Eye wash with Brass inject mould with epoxy powder coated body with auto released Valve and cup shaped water dispenser with min 1/2 HP power pressure booster pump 184 Counter Height Stools :Supply and erection of counter height stools ( bar stools ) of following specifications : Revolving adjustable Chrome plated steel body chairs with resistance to the corrosion. Cushion Seat with Lift mechanism for Adjustment of height. Minimum height 750mm before expansion. Medium Back rest and arm rest. Item shall be of reputed make. 185 Office Chair: Non-revolving executive chair with fixed armrest providing natural resting for arms. Seat with PU cutted foam backed fabric, back rest with mesh type fabric, Upholstery: Heavy duty rubber backed fabric in BLACK ( Size -55x60 cm) 186 Executive Chair: Medium back ergonomic chair with five nos. star shaped Nylon base. Castor: 50mm diameter nylon twin wheel, gas lift height adjustment, back angle adjustment , Fixed armrest providing natural resting for arms. Seat with PU coated foam backed fabric, back rest with mesh type fabric, upholstery: Heavy duty rubber backed fabric in BLACK 187 Revolving Chair: Medium back ergonomic chair with five nos. star shaped Nylon base. Castor: 50mm diameter nylon twin wheel, gas lift height adjustment, back angle adjustment , Fixed armrest providing natural resting for arms. Seat with PU coated foam backed fabric, back rest with mesh type fabric, upholstery: Heavy duty rubber backed fabric in BLACK 188 Cabinet/Wardrobe: Providing and fixing Cabinet/Wardrobe unit with 18 mm thick Multi wood board with one side decorative and other side balancing lamination. cupboard shutters edge to be sealed with PVC edge bending tape 2.00 mm thick of approved brand including ISI marked nickel plated bright finishing M.S. piano hinges conforming to IS:3818 marked with fixing chromium plated brass 50 mm cupboard or wardrobe knobs, special quality chromium plated brass cupboard locks with six levers of approved quality including necessary screws etc. complete. Depth of shelves to be 300-600mm and shelves to be fix with proper support and bracket holders. as per layout drawing approved by Engineer in charge. Make laminate: Greenlam/ Merino / Century. Only front elevation will be measured. 189 Supply and erection of Airport type 3 seater waiting chair with powder coated chromium finish having minimum dimensions 1675mm length X 710mm width X 775mm total height and 400mm seat height . Seat: High quality cold rolled 1.2mm thick steel perforated sheet pressed and welded to form the shape. Arm & Leg: High quality 1.2mm thick MS Tube / Sheet . Cross bar: High quality cold rolled 2mm thick steel sheet pressed and welded to form the shape. 190 Table of size Min 2300x600mm Made of minimum 18mm BWR ISI (303 Grade) plywood (Century, Greenply, Fineply or equivalent). On top and all sides with 1mm thick hot press (3M or Henkel) laminates (Brand MERINO, Associates or equivalent) of approved colour and pattern as per the design. The table is provided with 1 drawer, 1 Storage, 1 key board locks, handles, mini fix, dowels and screws. Exposed edges to be finished with 0.8 mm edge band as per specified colour. 191 Supply of wooden table with one drawer and Cupboard unit made of hard wood varnishing/painting all complete. Size: 1200x600x750mm 192 Providing & supply of Conference Table with executive chair of 13 Pax with the following specifications.Table top size :3600 x 1200mm. Table Tops –made of 25mm thick MDF with waterfall top edges finished in PVC Membrane using unique wrap around technology for better aesthetics & long lasting use. Under structure – Legs made of 25 mm thick standard Black matt colour post formed panels interconnected with 18mm thick standard Black matt colour pre-laminated modesty panels, with height adjustable levelers to take care of uneven floors. Wire Management & Concealed wire management to take care of basic wiring requirements both horizontally & vertically. For closed configurations, liftable top cover, made of 12mm MDF finished in PVC Membrane, is provided to access the horizontal wire carrier. Vertical wire management is through flexible vertical wire manager, popup grommet with power & RJ45 Socket. Designed for Flexibility through modular Construction, PVC Membrane Finish Tops for seamless surface, Post formed Legs for safe use, Provision for easy wire management, Upgradeable / reconfigurable for future needs. 13 Nos Revolving adjustable type Medium height Back Office Chair with arm rest with back tilt and swivel mechanism constructed out of mild steel and high quality plastic. 193 Supply of wooded Chairs with armrest of Hard Wood Plank Seat and Reaper Back. 194 Supply of Wooden Bench and Desk made up of Mahagani of minimum size - Bench Size :1 83x30X46cm Desk Size :183x41x75 cm 195 Supply and installation of steel podium made of SS304 with min dimensions 500mm X 450 mm X 1200mm and having a sloped top surface, and having a decorative/ plain front face all made of SS 304 as per the design and approvals of the architect/ Engineer - In - Charge 196 Wiring-General Electrical work 197 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C 198 Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. 199 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 2x1.5 sq.mm + 1x1.5 sq.mm earth wire 200 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire 201 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 2 X 4 sq. mm + 1 X 4 sq. mm earth wire 202 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 2 X 6 Sq.mm + 1 x 6 sq.mm earth wire 203 Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C 204 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 2 X 10 sq. mm + 1 X 6 sq. mm earth wire 205 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 2 X 16 sq. mm + 1 X 6 sq. mm earth wire 206 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 4 X 4 sq. mm + 2 X 4 sq. mm earth wire 207 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 4 X 10 sq. mm + 2 X 6 sq. mm earth wire 208 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 4 X 16 sq. mm + 2 X 6 sq. mm earth wire 209 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required. 20 mm 210 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm 211 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required. 32 mm 212 Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor,unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. 2 Pair 213 Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required. 214 Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. 215 Fixtures 216 Supply and Fixing suitable size modular GI box with cover in front on and providing and fixing 1 no RJ 45 including connections as required. 217 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings). 218 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. 219 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.Telephone socket outlet 220 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm) 221 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.TV antenna socket outlet 222 Supply and Installation of surface/recess mounted LED 2x2 luminaire with CRCA housing suitable with fully diffused diffuser for general lighting. The luminaire should have CRI > 80 and CCT of both 6500K/5700K, Cool White Light. The luminaire shall be compliant with IP20 and IK02 classification. Luminaire shall be designed to emit at least 3700 nominal lumens and efficacy of atleast 105 lumen/watt and Minimum system wattage of 36 Watts. The luminaire shall be designed so as to ensure lumen depreciation of up to 30% over 50k burning hours. The electronic driver used shall have a power factor >0.95 and THD. Make-Philips, Crompton, Wipro or equivalent 223 Supply, conveyance and Installation of compact, 2 feet,10-15W,LED tube light with high lumen giving soft glare free light including all required mounting accessories, frames complete. (Philips/WIPRO/Havells or equivalent) 224 Supply, Installation of surface mounted LED Tubelight. The luminaire should have CRI > 80 and CCT of both 6500K/5700K. The luminaire shall be compliant with IP20 and IK02 classification. Luminaire shall be designed to emit at least 3600 nominal lumens and efficacy of atleast 105 lumen/watt and Minimum system wattage of 30 Watts. The luminaire shall be designed so as to ensure lumen depreciation of up to 30% over 25k burning hours. The electronic driver used shall have a power factor >0.95 and THD. Make - Philips, Crompton, Wipro, Havells 225 Supply, Installation of surface/recess mounted LED Round/Square luminaire with CRCA housing suitable with fully diffused diffuser for general lighting in office areas. The luminaire should have CRI > 80 and CCT of both 6500K/5700K. The luminaire shall be compliant with IP20 and IK02 classification. Luminaire shall be designed to emit at least 3600 nominal lumens and efficacy of atleast 110 lumen/watt and Minimum system wattage of 10 -15 Watts. The luminaire shall be designed so as to ensure lumen depreciation of up to 30% over 50k burning hours. The electronic driver used shall have a power factor >0.95 and THD. Make-Philips, Crompton, Wipro 226 Supply, conveyance and Installation of compact 10-15W LED Bulkhead Light giving soft glare free, Cool White light & complete with electronic driver including all required mounting accessories, frames, complete ( Make: Philips/WIPRO/Havells or equivalent) 227 Supply, Installation, Testing and Commissioning of 1400 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, ashers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. Make: Atomberg/Havells/ Orient Electric/ Crompton or equivalent 228 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, ashers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. Make: Atomberg/Havells/ Orient Electric/ Crompton or equivalent 229 Supplying, conveyance and Installation of 150-250 mm sweep,1350 rpm, 3 - 5 blade BLDC Exhaust Fan including frames and all mounting accessories complete.Recommended Make: Atomberg Efficio/Crompton Brisk Air 230 Supplying, conveyance and Installation of BLDC Type Wall Fan having 3 blade, 400 mm sweep, Speed 1350 rpm, Air Delivery 70 CMM minimum, Wall Mount Fan including frames and all mounting accessories complete. Recommended Make: Atomberg Renesa/V-Guard ENVIRO WF BLDC/Havells Platina 231 Supply, Installation, Testing and Commissioning of 450 mm sweep, 900 rpm heavy duty exhaust fan with louver in existing opening including making good the hole to suite the size of above fan complete with connections using 3 core 1.5sqmm multi core pvc sheathed copper conductor cable etc as required. 232 SITC of skirting light fitting with white LED 3 module along with suitable size modular metal box with inner and outer plates with all accessories. 233 Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providng and fixing 2 Nos. 3 pin 5/6 A modular socket outlets and 2 Nos. 5/6 A modular switches, connection etc. as required. (For light plugs to be used in non residential buildings). 234 Supplying & fixing suitable size Gl box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, C curve including connections, painting etc. as required. lCD 235 Supply and installation of 2 Nos. 4 ft MS powder-coated hanging rods for tube lights, including supply and laying of 1.5 sqmm copper PVC insulated FRLS wire (3 runs: Phase, Neutral, Earth), necessary hardware (ceiling clamps, saddles, junction box, connectors), complete mounting, terminations, testing, and labour charges — complete in all respects. 236 Network and CCTV System 237 Supply of 16 ports Network Switch, Rack-mountable 10/100/1000 Mbps, Switching capacity 35.7 Mbps Features: Flow control, Layer 2 switching, auto-negotiation, auto- uplink (auto MDI/MDI-X), Weighted Round Robin (WRR) queuing, Quality of Service (QoS) Power: AC 120/230 V (50/60 Hz) complete. Make D-Link/TP Link/Cisco or equivalent 238 Supply Installation Testing and Commissioning of 32 channel embedded Linux NVR (Network Video Recorder), must connect 32 channel IP cameras, Should support min 2 SATA HDD and each should support Min 2TB and must record video simultaneously, (Recording Type: Continuous, Motion Detection, Alarm, Smart Event, Event Motion Detection, Alarm, Smart Event), Video Compression H.265(HEVC)/H.264+/H.264, 2 Year Warranty, Image quality should be maintained throughout the warranty period. Make: CP Plus/Hikivision/Dahua or equivalent 239 Network Switch for CCTV. 16 Port PoE Switch 1000BASE-T Copper Ethernet PoE+ connections, 10M/100M/1G RJ-45 copper ports, 1000BASE-X Fiber SFP ports, 16 port Auto sensing 10/100/1000 Mbps PoE, minimum CPU memory 512 MB with 2 SFP/combo ports, Energy Efficient Ethernet (IEEE 802.3az) Make: CP Plus/Netgear or equivalent 240 Supply, Conveyance and Installing of 2MP IP Dome/Bullet Camera having Progressive Scan True Day and Night Colour IR Camera having effective pixel of 2 MP, Video frame rate of 2MP @30FPS, Minimum illumination of 0.01 [email protected], 0 lux@IR On, 20 M IR Range, 24 IR LED, AWB, AGC, BLC, 2D Noise reduction, with 3.6mm board lense, 12 VDC, PoE IP67 rated weatherproof performance. 1 year warranty. Make: Bosch/CP Plus/Honeywell or equivalent 241 Supply and fixing of 6U wall mounting rack with supply and fixing of mounting brackets for support Lockable Front Door and Detachable Side Doors, Cable Manager and PDU of 4 or 6 sockets including cooling fan with accessories complete 242 Supply Installation Testing & Commissioning of 16 Port Loaded Cat 6 - U/UTP Modular Toolless Patch Panel having a metal structure enabling them to be durably fixed to the uprights of the 19 chassis. Include rear cable manager to hold cables without need for cable ties. The termination of I/0s shall be without any manual crimping tools. 243 Supply and fixing of 4U wall mounting rack with supply and fixing of mounting brackets for support Lockable Front Door and Detachable Side Doors, Cable Manager and PDU of 4 or 6 sockets including cooling fan with accessories complete. 244 Supply and connecting 2 meter long CAT6 cable Patch cord having RJ45 connectors crimped at both ends, to the existing outlets as required. Make: D-Link/TP-Link or equivalent 245 Supply and Installation of LED Color display of minimum 32 inch screen, complete, UHD display Make: LG/Samsung/Panasonic or equivalent. 246 Supplying and drawn of UTP 4 pair CAT 6 LAN cable in the existing surface/recessed steel/PVC conduit as required1 run of Cable 247 Supply, Installation and Integration of Dual Band WiFi Access Point on false ceiling along with accessories, having Fast Wireless Speed, simultaneous 2.4GHz 300Mbps and 5GHz, 867Mbps Dual Band connections for 1.2Gbps of total available bandwidth, Superior Coverage of Four Fixed External antennas provide stable wireless connections and optimal coverage, App Control, Interface of 1× 10/100 Mbps WAN Port and 4× 10/100 Mbps LAN Ports having Working Modes (Router Mode / Access Point Mode). Make: TP-Link/Netgear/DLink or equivalent 248 UPS 249 Supply, Installation, Testing and Commissioning of True on-line Double Conversion 10 KVA UPS system with 3:3 Crest Factor Three Phase Input Three Phase Output. Inversion shall be Microprocessor controlled with instantaneous sine wave Control using IGBT. UPS shall have standard display features, alarms, safeties, etc Input Voltage range : a) Phase – Three Phase with ground b)Voltage range 190 VAC – 470 VAC c)Input Frequency :50/60 Hz d)Power Factor : 0.95 or above e)THD : less than 5% with full load Bypass f) Voltage Range – 200VAC – 240 VAC ) Frequency range – 45-55 Hz/55-65 Hz Output Voltage Range h)Voltage Range – 200VAC – 240 VAC i)Frequency range – 50/60 Hz j)Voltage distortion – linear load <= 2% k)Voltage distortion – nonlinear load <= 5% l)Output waveform – pure sinewave m) Crest Factor – 3:1 Minimum Back up time : Continuous 30 Minutes at full load Rectifier shall be Full wave Type (Shall fully meet the specified input power requirements) Battery Type: Sealed Lead Acid Maintenance Free DC Voltage : 96V DC System, Battery Nos and capacity shall be designed for optimum storage space. Installation &Commissioning Required Breakers also needs to be provided in input and output side for the UPS. Make: Liebert Vertiv/APC by Schneider/Numeric by Legrand 250 Cable Trays 251 Supplying and installing following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.375 mm width X 50 mm depth X 2.0 mm thickness 252 Supplying and installing following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.150 mm width X 50 mm depth X 1.6 mm thickness 253 Fan Clamp 254 Providing and fixing 16 mm S.S. Fan clamps of standard shape and size in existing R.C.C. slab, including cutting chase, anchoring clamp to reinforcement bar, including cleaning, refilling, making good the chase with matching concrete, plastering and painting the exposed portion of the clamps complete. 255 DB and Switchgear 256 Supply and installation ofsheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - three phase double cover (IP 42/43) 257 Supply and installation ofsheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - double cover TPN vertical DB with provision for fixing MCCB as incomer and SP/ TP MCB as outgoing (IP 42/43) 258 Supply and installation ofsheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required6 way (8+12) - double cover TPN vertical DB with provision for fixing MCCB as incomer and SP/ TP MCB as outgoing (IP 42/43) 259 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator6 way, Double door 260 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole 261 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole and netural 262 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Double pole 263 Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps 264 Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps 265 Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps 266 Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps 267 Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps 268 Supplying and fixing TP sheet steel enclosure on surface/ recess along with 16/25/32amps 415 volts C curve TP MCB complete with connections, testing and commissioning etc. as required. 269 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole 270 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole and neutral 271 Earthing and Lightning Arrestor 272 Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re- filling etc. as required. 273 Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required. 274 Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required. 275 Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. 276 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. 277 Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm) 278 Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 nos. of G.I. bolts, nuts, chuck nuts and spring washers etc. complete as required. 279 Laying copper/ G.I. tape 32 mm X 6 mm from earth electrode directly in ground as required. 280 Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube,having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required. 281 Jointing copper / G.I. tape (with another copper/ G I tape, base of the finial or any other metallic object) by riveting / nut bolting/ sweating and soldering etc as required. 282 Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For horizontal run) 283 Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For vertical run) 284 Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required4.75 mm copper conductor (6 SWG) 285 Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.4.00 mm (8 SWG) 286 Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.4.75 mm (6 SWG) 287 Street Lights 288 Supply Conveyance, installation, testing and commissioning of 36/40W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer) 289 Supply, fabrication, conveyance and fixing the following sizes of B class GI pipe bent to shape / cut and welded to shape and fixing the same to wall / parapet using clamps as noted along with each size, painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer, making good the damages, colour washing etc as required.32 mm dia with HG company fabricated clamps 290 Water Purifier 291 Supply and Installation of Water Purifier having Multi-Stage Filtration: RO (Reverse Osmosis), UV (Ultraviolet), UF (Ultrafiltration), Storage Capacity: 7-9 Liters, Purification Features: RO: Removes dissolved impurities, heavy metals, and salts.UV: Kills bacteria, viruses, and other microorganisms. UF: Filters out fine particles and microorganisms. Mineral Booster: Adds essential minerals to enhance water taste.TDS Controller: Adjusts Total Dissolved Solids for taste preference. ActiveCopper: Infuses copper ions into the water for added health benefits.Aqua Taste Booster: Enhances the taste and maintains optimum pH level. In-Tank UV Disinfection: Keeps stored water pure.Smart Display/Indicators: Alerts for filter change, UV fail, water level, and service needs. Super Fine Sediment Filter: Removes fine and coarse particulate impurities. Water Level Indicator: Monitors the purified water level in the storage tank. Make: Aquaguard Aura 7L/ Bluestar Aristo 7L/Kent Grand Plus ZWW 9-Litre/ LG 8L 292 LT Cabling and Termination 293 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.2 core 6 sq mm with factory made clamp 294 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 35 sq mm with factory made clamp 295 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 10 sq mm with factory made clamp 296 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 16 sq mm with factory made clamp 297 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 25 sq mm with factory made clamp 298 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 240 sq mm 299 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 240 sq. mm (62mm) 300 Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.3.5 core 400 sq mm 301 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 400 sq. mm (82mm) 302 LT Panels 303 Fabrication, Supply, Installation, Testing & Commissioning of floor mounted, cubical type, dust & vermin proof, powder coated of approved shade Electrical panel fabricated out of sheet steel not less than 2.0 mm thick. Wherever necessary, such sheet steel members shall be stiffened by angle iron frame work. General construction shall employ the principle of compartmentalization and segregation for each circuit. Unless otherwise approved, incomer and bus section panels or sections shall be separate and independent and shall not be mixed with sections required for feeders. Each section of the rear accessible type panel shall have hinged access doors at the rear. Overall height of the panel shall not exceed 2.4 meters. Operating levers, handle etc. of highest unit shall not be higher than 1.7 meters. Multi-tier mounting of feeder is permissible. The general arrangement for multi-tier construction shall be such that the horizontal tiers formed present a pleasing and aesthetic look. Cable entries for various feeders shall be either from top or bottom. Through cable alleys located in between two circuit sections, either in the rear or in the front of the panel. All cable terminations shall be through gland plates. There shall be separate gland plate for each cable entry so that there will not be dislocation of already wired circuits when new feeders are added. Cable entry plates shall therefore be sectionalized. The construction shall include necessary cable supports for clamping the cable in the cable alley or rear cable chamber. The bus bars shall be of aluminium of high conductivity electrolytic quality and of adequate section. All bus bars and connections shall be suitably sleeved / insulated in approved manner. All voltmeters and ammeters shall befl ush mounted of size minimum 96 mm conforming to class 1.5 of IS 1248 for accuracy. All voltmeters shall be protected with MCB. On all the incomers of M.V panels, ON/OFF indicating LED lamps shall be provided and shall be suitable for operation on AC supply. Phase indicating LED lamps shall be associated with necessary ON/OFF toggle switch. All small wiring for Controls, Indication etc. shall be with suitable FRLS/ HFFR (halogen free fire retardant) copper conductor cables. Identification ferrules shall be used at both ends of the wires. The panel shall comprise of incomers, outgoing feeders and bus coupler as specified. The entire switch panel shall be cubical type generally conforming to IS 8623:1993 for factory assembled switch board. All incoming AIR CIRCUIT BREAKER/ MCCB shall have suitable adjustable tripping current and the time delay settings. The entire panel shall have a common earth bar of size as specified with two terminals for earth connections. The panel shall be suitable for operation on 415V, 3 phase, 50 Hz AC supply with enclosure protection class IP-42 as required.Incomer : 400A 3kA 4 Pole MCCB - 1no Ics = 100% Icu rating Digital Voltmeter 0- 500V with selector switch & Digital ammeter (0-400A) with selector switch and CTs etc. LED type RYB phase indication lamps, ON, OFF, Trip indication lamps, set of aluminium bus bar 400A. Out going : 250A ,50kA 4 Pole MCCB - 2no Ics = 100% Icu, (with Hylam sheet & warning signages as required) Switch gear make should as per approved make list. Panel shall meet all necessary specifications as per local electrical body/Inspectorate norms. 304 Lift panel- Fabrication, Supply, Installation, Testing & Commissioning of floor mounted, cubical type, dust & vermin proof, powder coated of approved shade Electrical panel fabricated out of sheet steel not less than 2.0 mm thick. Wherever necessary, such sheet steel members shall be stiffened by angle iron frame work.General construction shall employ the principle of compartmentalization and segregation for each circuit. Unless otherwise approved, incomer and bus section panels or sections shall be separate and independent and shall not be mixed with sections required for feeders. Each section of the rear accessible type panel shall have hinged access doors at the rear. Overall height of the panel shall not exceed 2.4 meters. Operating levers, handle etc. of highest unit shall not be higher than 1.7 meters. Multi-tier mounting of feeder is permissible. The general arrangement for multi-tier construction shall be such that the horizontal tiers formed present a pleasing and aesthetic look. Cable entries for various feeders shall be either from top or bottom. Through cable alleys located in between two circuit sections, either in the rear or in the front of the panel. All cable terminations shall be through gland plates. There shall be separate gland plate for each cable entry so that there will not be dislocation of already wired circuits when new feeders are added. Cable entry plates shall therefore be sectionalized. The construction shall include necessary cable supports for clamping the cable in the cable alley or rear cable chamber. The bus bars shall be of aluminium of high conductivity electrolytic quality and of adequate section. All bus bars and connections shall be suitably sleeved / insulated in approved manner. All voltmeters and ammeters shall be fl ush mounted of size minimum 96 mm conforming to class 1.5 of IS 1248 for accuracy. All voltmeters shall be protected with MCB. On all the incomers of M.V panels, ON/OFF indicating LED lamps shall be provided and shall be suitable for operation on AC supply. Phase indicating LED lamps shall be associated with necessary ON/OFF toggle switch. All small wiring for Controls, Indication etc. shall be with suitable FRLS/ HFFR (halogen free fire retardant) copper conductor cables. Identification ferrules shall be used at both ends of the wires. The panel shall comprise of incomers, outgoing feeders and bus coupler as specified. The entire switch panel shall be cubical type generally conforming to IS 8623:1993 for factory assembled switch board. All incoming AIR CIRCUIT BREAKER/ MCCB shall have suitable adjustable tripping current and the time delay settings. The entire panel shall have a common earth bar of size as specified with two terminals for earth connections. The panel shall be suitable for operation on 415V, 3 phase, 50 Hz AC supply with enclosure protection class IP-42 as required.Incomer : 1) 63A 36kA 4 Pole MCCB - 1no Ics = 100% Icu rating, THERMAL MANGNETIC RELEASEDigital Voltmeter 0-500V with selector switch & Digital ammeter (0-63A) with selector switch and CTs etc. LED type RYB phase indication lamps, ON, OFF, Trip indication lamps, set of aluminium bus bar 63A. Out going : 1) 40A ,16-25kA TP MCB - 6 no Ics = 100% Icu, (with Hylam sheet & warning signages as required) Switch gear make should as per approved make list.Panel shall meet all necessary specifications as per local electrical body/Inspectorate norms. 305 Sub Panel- Fabrication, Supply, Installation, Testing & Commissioning of floor mounted, cubical type, dust & vermin proof, powder coated of approved shade Electrical panel fabricated out of sheet steel not less than 2.0 mm thick. Wherever necessary, such sheet steel members shall be stiffened by angle iron frame work.General construction shall employ the principle of compartmentalization and segregation for each circuit. Unless otherwise approved, incomer and bus section panels or sections shall be separate and independent and shall not be mixed with sections required for feeders. Each section of the rear accessible type panel shall have hinged access doors at the rear. Overall height of the panel shall not exceed 2.4 meters. Operating levers, handle etc. of highest unit shall not be higher than 1.7 meters. Multi-tier mounting of feeder is permissible. The general arrangement for multi-tier construction shall be such that the horizontal tiers formed present a pleasing and aesthetic look. Cable entries for various feeders shall be either from top or bottom. Through cable alleys located in between two circuit sections, either in the rear or in the front of the panel. All cable terminations shall be through gland plates. There shall be separate gland plate for each cable entry so that there will not be dislocation of already wired circuits when new feeders are added. Cable entry plates shall therefore be sectionalized. The construction shall include necessary cable supports for clamping the cable in the cable alley or rear cable chamber. The bus bars shall be of aluminium of high conductivity electrolytic quality and of adequate section. All bus bars and connections shall be suitably sleeved / insulated in approved manner. All voltmeters and ammeters shall be fl ush mounted of size minimum 96 mm conforming to class 1.5 of IS 1248 for accuracy. All voltmeters shall be protected with MCB. On all the incomers of M.V panels, ON/OFF indicating LED lamps shall be provided and shall be suitable for operation on AC supply. Phase indicating LED lamps shall be associated with necessary ON/OFF toggle switch. All small wiring for Controls, Indication etc. shall be with suitable FRLS/ HFFR (halogen free fire retardant) copper conductor cables. Identification ferrules shall be used at both ends of the wires. The panel shall comprise of incomers, outgoing feeders and bus coupler as specified. The entire switch panel shall be cubical type generally conforming to IS 8623:1993 for factory assembled switch board. All incoming AIR CIRCUIT BREAKER/ MCCB shall have suitable adjustable tripping current and the time delay settings. The entire panel shall have a common earth bar of size as specified with two terminals for earth connections. The panel shall be suitable for operation on 415V, 3 phase, 50 Hz AC supply with enclosure protection class IP-42 as required. Incomer : 1) 63A 36kA 4 Pole MCCB - 1no Ics = 100% Icu rating, THERMAL MANGNETIC RELEASEDigital Voltmeter 0-500V with selector switch &Digital ammeter (0-63A) with selector switch and CTs etc. LED type RYB phase indication lamps, ON, OFF, Trip indication lamps, set of aluminium bus bar 63A. Out going : 1) 32A ,16-25kA 4 Pole MCCB - 4 no Ics = 100% Icu, (with Hylam sheet & warning signages as required) Switch gear make should as per approved make list. Panel shall meet all necessary specifications as per local electrical body/Inspectorate norms. 306 SSB2- Fabrication, Supply, Installation, Testing & Commissioning of floor mounted, cubical type, dust & vermin proof, powder coated of approved shade Electrical panel fabricated out of sheet steel not less than 2.0 mm thick. Wherever necessary, such sheet steel members shall be stiffened by angle iron frame work.General construction shall employ the principle of compartmentalization and segregation for each circuit. Unless otherwise approved, incomer and bus section panels or sections shall be separate and independent and shall not be mixed with sections required for feeders. Each section of the rear accessible type panel shall have hinged access doors at the rear. Overall height of the panel shall not exceed 2.4 meters. Operating levers, handle etc. of highest unit shall not be higher than 1.7 meters. Multi-tier mounting of feeder is permissible. The general arrangement for multi-tier construction shall be such that the horizontal tiers formed present a pleasing and aesthetic look. Cable entries for various feeders shall be either from top or bottom. Through cable alleys located in between two circuit sections, either in the rear or in the front of the panel. All cable terminations shall be through gland plates. There shall be separate gland plate for each cable entry so that there will not be dislocation of already wired circuits when new feeders are added. Cable entry plates shall therefore be sectionalized. The construction shall include necessary cable supports for clamping the cable in the cable alley or rear cable chamber. The bus bars shall be of aluminium of high conductivity electrolytic quality and of adequate section. All bus bars and connections shall be suitably sleeved / insulated in approved manner. All voltmeters and ammeters shall be fl ush mounted of size minimum 96 mm conforming to class 1.5 of IS 1248 for accuracy. All voltmeters shall be protected with MCB. On all the incomers of M.V panels, ON/OFF indicating LED lamps shall be provided and shall be suitable for operation on AC supply. Phase indicating LED lamps shall be associated with necessary ON/OFF toggle switch. All small wiring for Controls, Indication etc. shall be with suitable FRLS/ HFFR (halogen free fire retardant) copper conductor cables. Identification ferrules shall be used at both ends of the wires. The panel shall comprise of incomers, outgoing feeders and bus coupler as specified. The entire switch panel shall be cubical type generally conforming to IS 8623:1993 for factory assembled switch board. All incoming AIR CIRCUIT BREAKER/ MCCB shall have suitable adjustable tripping current and the time delay settings. The entire panel shall have a common earth bar of size as specified with two terminals for earth connections. The panel shall be suitable for operation on 415V, 3 phase, 50 Hz AC supply with enclosure protection class IP-42 as required.Incomer : 1) 250A 36kA 4 Pole MCCB - 1no Ics = 100% Icu rating, THERMAL MANGNETIC RELEASEDigital Voltmeter 0-500V with selector switch & Digital ammeter (0-250A) with selector switch and CTs etc. LED type RYB phase indication lamps, ON, OFF, Trip indication lamps, set of aluminium bus bar 250A. Out going : 1) 63A ,16-25kA 4 Pole MCCB - 8 no Ics = 100% Icu, (with Hylam sheet & warning signages as required) Switch gear make should as per approved make list. Panel shall meet all necessary specifications as per local electrical body/Inspectorate norms. 307 Transformer 308 Supply , Installation, Testing and commissioning of 500 kVA outdoor unitized substation with an 11kV/433V dry-type cast resin transformer and a 630A VCB typically includes a compact prefabricated design conforming to IEC62271-202 standards, offering IP53/IP23 protection, and featuring compartmentalized construction to prevent accidental entry into energized areas. The substation is designed to withstand electrical impulses, thermal, and dynamic stresses, ensuring reliable and robust performance with low power loss and noise levels. The installation involves placing the substation on a prepared concrete plinth, connecting high-tension (HT) and low-tension (LT) cables, and ensuring proper earthing and safety measures. The commissioning process includes testing the transformer, switchgear, and protection systems to verify operational integrity. Make: Unipower/Intrans/Voltamp 309 MSB and APFC Panel 310 Supplying, installation, testing & commissioning of cubical type MAIN SWITCH BOARD suitable for 415 V, 3 Phase, 4 Wire 50 Hz AC supply system having front surface area 6 sq.mtr (Approx.) fabricated in compartmentalized design from CRCA sheet steel of 2 mm thick for frame work and covers, 3 mm thick for gland, plates i/c cleaning & finishing complete with 7 tank process for powder coating in approved shade, having 630 Amp capacity extensible type TPN aluminium alloy bus bars of height conductivity, DMC / SMC bus bars of high conductivity, DMC/ SMC bus bar supports, with short circuit withstand capacity of 31 MVA for 1 Sec., bottom base channel of MS section not less than 100 mm x 50 mm x 5 mm thick, fabrication shall be done in transportable sections, entire panel shall have a common copper earth bar of size 25 mm x 5 mm at the rear with 2 Nos. earth stud, solid connections from main bus bar to switch gears with required size of Al. bus bars and control wiring with sq. mm. PVC insulated copper conductor S/C cable, cable alleys, cable gland plates in two half, i/c providing following switch gears :- Interlocking:Electrical through advance contacts in MCCB/ ACB’s (incomers & bus couplers) and mechanical (castel key) interlocking should be provided to ensure that only one supply is available at a time on each section of bus and to eliminate any possibility of accidentally approaching two supplies at one bus section.Interlocking b(I) Incoming : 2 Nos 800 Amps (DG and MAINS) each four pole ACB of fault breaking capacity 50 KA (Ics=Icu upto 433 V manually operated, fitted with interlocked door, automatic safety shutters, mechanical ON/OFF and service/test/isolated position indicators and frame earthing contact, conforming to IS 1397- 2 : 1993 as amended up-to-date complete with following accessories for each MCCB(a) Independent manual spring closing mechanism- 1 No.(b) Microprocessor release (EMI & EMC certified) for over current, earth fault & short circuit protection- 1 set.(c) Digital* type Voltmeter (0-500 V), with selector switch & back up HRC fuses/MCBs-1 set. (d) Digital* type Ammeter (0-.600 Amp), with selector switch and one set of 3 nos. CT’s of ratio. 800/5A Class I accuracy and 15 VA burden- 1set. (Ratio to be fi lled up).(e) 3 Nos. Phase indication LED lamps with 2 Amp back up HRC fuse, breaker ‘ON’ indicating light with 2 A HRC fuse, test terminal block set, fuses, circuits as per standard practice, auxiliary contacts for positive interlocking of the breakers as required.(f) Shunt trip coil 220 V A.C. (II) Bus Bars :TPN aluminium bus bars of minimum of 800 Amps capacity with heat shrinkable coloured sleeves and i/c DMC/SMC bus bar cross section, size supports & their spacing etc. for withstanding fault level of 31 MVA for 1 Sec (II) Outgoing :(1) (a) 4 Nos. 250 Amp 4 Pole MCCB (Ics = 35 kA upto 433 V) (b) CT’s of ratio 250/5 Amps Nos. (c) Digital* type ammeter (0- 400 Ap) with selector switch set. (2) (a) 1 Nos. 200 Amp4 Pole MCCB for (Ics = 35 kA upto 433 V) (b) CT’s of ratio 200/5 Amps set (c) Digital* type ammeter (0- 250 Amp) with selector switch set. (3) 3 Nos 160 Amp 4 Pole MCCB (Ics = 35 kA upto 433 V) (b) CT’s of ratio 160/5 Amps set (c) Digital* type ammeter (0- 200 Amp) with selector switch set. The switchgears/measuring instruments shall be as per the Choice of the Engineer in charge. The panel shall be mounted on required structural steel supports and frames for mounting, the price quoted shall be inclusive of the same. The panel shall have suitable provision for connecting to the incoming cables of 3R x 400 sqmm XLPE Aluminium cables and shall be provided with necessary earth leakage relays as per the Inspectorate Norms. The panel shall be as per the IS standards and shall conform to all norms of EB/Inspectorate/CEA. Make of Switchgear : ABB/L & T/Schneider Electric/Siemens/Legrand 311 Design, Manufacture, Supply, Installation, Testing and Commissioning of Automatic Power correction Panel having Incomer: 250A, TPN MCCB, Digital Multifunction meter for V,A,F,PF With CTs CL:1 with RYB Indication lamps-1 Set 250A Aluminium bus bar with heat shrinkable insulation sleeves-1 set, Intelligent power factor controller with control MCBs etc. complete The panel shall comprise of suitable combination of capacitor banks upto a total of 100 kVAR and shall be designed as per the standards of Electrical Inspectorate/CEA. 312 DG and AMF Panel 313 Supply, Installing, Testing and Commissioning of & Silent Type& Diesel Generating set having CPCB IV+ acoustic enclosure having Prime Power Rating of 500 KVA, 415 volts at 1500 RPM, 0.8 lagging power factor at 415 V suitable for 50 Hz, 3 phase system & for 0.85 Load Factor and consisting of the followings: Diesel engine radiator cooled, electric start, of suitable BHP at 1500 RPM suitable for above output of alternator capable of taking 10% over loading for one hour after 12 hours of continuous operation. The engine will be fitted complete with all the required accessories. Engine mounted Instrument Panel fitted with and having digital display and necessary indication coupled to Synchronous alternator rated at 500 KVA, 415 volts at 1500 RPM, 3 phase 50 Hz, AC supply with 0.8 lagging power factor. Both the engine and alternator shall be mounted on suitable base frame made of MS channel with necessary reinforcement which shall be installed on suitable cement concrete foundation and vibration isolation arrangement as per recommendations of manufacturer. Daily service fuel tank of 440-460 litres capacity fabricated out of 3 mm thick M.S. sheet complete with all standard accessories and fuel piping between fuel tank and diesel engine with MS class ‘C’ pipes of suitable dia. Complete with valves, level indications & accessories as required as per specifications. Dry exhaust manifold with hospital exhaust silencer and catalytic convertor. 12V/24V DC starting system comprising of starter motors: voltage regulator and arrangement for initial excitation complete with suitable nos. of batteries (lead acid type) as required as per specifications. Acoustic and weather proof enclosure with arrangement for fresh air intake for cooling of the engine & alternator, extraction, discharging hot air in to the atmosphere as per specifications. 314 Design, Fabricating, Supply, Installing, Testing & Commissioning of automatic mains failure control including auto by-pass panel, suitable for 500 KVA silent type DG set complete with relays, timers, set of CTs for metering & protection and energy analyser to indicate currents, phase and line voltages, frequency, power factor, KWH, KVARH & provision for overload, short circuit, restricted earth fault, under frequency, control cabling from AMF panel to diesel engine and elsewhere if required, all complete and inter locking including the following: (a) 1 Nos. 630 Amp., 50 kA (Ics=100%Icu), 4 pole, current limiting type MCCB with microprocessor based release with overload setting of 50-100% having adjustable OL & SC. Set at 350A (b) Auto/Manual/Test/Off selector switch (c) 2 Nos. over voltage relay, 2 Nos. reverse power relay and 2 Nos. under voltage relay. (d) 3 Sets of current transformers 15 P 10 accuracy for protection and 15 VA class-I for metering(e) Energy analyser unit to indicate current voltage frequency power factor and KWH(f) Indicating lamps for load on mains and load on set(g) Fuse for instruments(h) Battery charger, complete with transformer/ rectifi er, D.C. voltmeter and ammeter, selector switch for trickle, off and boost and current adjustment.(i) Main supply failure monitor(j) Supply failure timer(k) Restoration timer(l) Control unit with three impulse automatic engine start/stop and failure to start lockout.(m) Impulse counter with locking and reset facility.(n) ON/OFF/Control circuit switch with indicator(o) Audio/Video annunciation for(i) High water temperature(ii) Low lubricating oil pressure(iii) Engine over speed(iv) Engine fails to start(v) Full load/maximum load warning. AMF Panel shall be connected to Main Switch Board incomer with necessary interlocking arrangement to prevent simultaneous switching on of power supplies. All integration between Main Switchboard and AMF Panel is under contractor scope. 315 HT Cable 316 Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium powercable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).3 core 300 sq mm 317 Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required:300 sq. mm 318 Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :300 sq. mm 319 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Above 120 sq. mm and upto 400 sq. mm 320 Air Conditioning Works 321 Supply, Installation, testing and commissioning of 3 x 3 Cassette type Air Conditioner of following capacity and specifications: Consisting of ceiling-mounted type room unit (fan coil) with cordless remote control and one number outdoor condensing unit comprising of energy-efficient suitable rotary compressor for operation on single-phase, 230 V, 50Hz supply, fixing the outdoor unit on a raised platform as per manufacturers recommendation, with R-32/R-410A or equivalent refrigerant and fixing of room (fan coil) unit on ceiling, standard 5 m distance refrigerant copper piping with 13mm nitrile rubber insulation, providing and making interconnection between room & condenser as per site conditions, comprising of 1 dia drain PVC pipe with insulation up to 5 m, canvas connections, full electrical cabling from power plug near indoor unit and to outdoor unit, ODU MS stand, first charge refrigerant gas, suitable stabilizer etc complete as required. (Make: Voltas, Blue Star, Daikin, Hitachi, Carrier or equivalent). Minimum 2 TR 3 Star rated (inverter type AC) as per BEE 322 Supplying additional copper piping of required size and connecting the same to the available piping and extension of the same through 100mm PVC duct inside false ceiling. 323 Electrical Dismantling Works 324 Dismantling of existing outdoor transformer and handing over to client as required by stacking the same within the campus premises, including accessories complete as per direction of engineer-in-charge 325 Dismantling of existing DG set 100 kVA, AMF panel etc and handing over to client as required by stacking the same within the campus premises, including accessories complete as per direction of engineer-in-charge 326 Electrical Works- Fire 327 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured copper power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 70 sq mm 328 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.2 core 6 sq mm with factory made clamp 329 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 16 sq mm with factory made clamp 330 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 35 sq mm with factory made clamp 331 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 6 sq. mm (19mm) 332 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 35 sq. mm (32mm) 333 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 70 sq. mm (38mm) 334 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm) 335 Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. 336 Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required4.00 mm copper conductor ( 8 SWG) 337 Supply of superior quality copper tubular cable socket and making core termination of cables of the following sizes including crimping etc. as required.10 sq mm 338 First Aid Hose reel &Wet Riser system 339 Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required.a.20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585b.20 mm nominal internal dia gun metal globe valve & nozzle. c.Drum and brackets for fixing the equipmets on wall.d.Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket.30 m 340 Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required100 mm dia 341 Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required :2 way-100 mm dia M.S. Pipe 342 Supply and fixing of Air release valve SS body of 25 mm dia (UL Listed). 343 Supply, installation, Testing and Commissioning of Lever operated Ball valves made of Cast iron conforms to IS 5312, at required locations.25 mm dia Make : Kartar/ Atom 344 Supplying and fixing orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required. 345 Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required :Stainless Steel (Grade 304) 346 Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required :Stainless Steel (Grade 304) 347 Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required :Single headed Stainless steel 348 Hose Box - Supply, Installation, Testing and Commissioning of Hose Box -Double door - (cabinet) to accommodate Two pieces of 63 mm dia fire hose along with one pair of 63 mm dia male & female couplings and one branch pipe. The cabinet is made of MS sheet, painted in approved red colour with glass fronted hinged doors and lock &key (UL Listed). 349 Supply and Installation of Fire Brigade Draw-out Collecting head of CI Body having gunmetal 63mm dia instantaneous male draw out confirming to IS:903 suitable to fit on 100mm dia pipe with necessary flanges, rubber gasket, nut & bolts and other items. 350 Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :100mm dia 351 Fire extinguishers 352 Supply &installation of ISI ABC type fire extinguisher of 4 kgs. Make SAFEX/ MINIMAX / CEASEFIRE or equivalent(UL Listed) 353 Supply &installation of CO2 type fire extinguisher of 4.5 kgs. Make SAFEX / MINIMAX / CEASEFIRE or equivalent 354 Supply & installation of water mist type fire extinguisher of 9 liters. Make SAFEX / MINIMAX / CEASEFIRE or equivalent 355 Supplying & Installing of Clean agent based automatic modular fire extinguisher (ceiling mounted) suitable for A,B,C class fires & electrical fires, Capacity- 5Kg 356 Supplying & Installing of Mechanical Foam (Stored Pressure) Type fire extinguisher of 9L capacity with mounting clamp. ISI approved. Make : SAFEX/MINIMAX/CEASEFIRE or equivalent 357 Fire Pumps & Fire Panel 358 Electric driven Main Fire Pump: Supplying, installation, testing and commissioning of Electric driven Main Fire Pump suitable for automatic operation and consisting of following, complete in all respects, as required : (a) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520. (b) Suitable HP Squirrel cage induction motor, TEFC, synchronous speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz, AC supply with IP 55 protection for enclosure, horizontal foot mounted type with Class-F insulation, conforming to IS-325. (c) M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) Suitable cement concrete foundation duly plastered with anti vibration pads.1620 lpm at 56 m Head 359 Supplying, installation, testing and commissioning of diesel engine driven main fire pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Diesel Driven Pump)Horizontal type, multistage, centrifugal pump of cast of iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520.Suitable HP, 1500 RPM water cooled with radiator, diesel engine conforming to relevant IS standard complete with auto starting mechanism, 12 /24 volts electric starting equipment, diesel tank, exhaust pipe extended upto 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications, painted with post office red colour etc. as required.M.S fabricated, common base plate, coupling, coupling guard, foundation bolts etc. as required.Suitable cement concrete foundation duly plastered and with anti vibration pads. 1620 lpm at 56 m Head 360 Supplying, installation, testing and commissioning of electric driven pressurisation pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Jockey Pump)a.Horizontal type, multistage, centrifugal pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS : 1520.b. Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase 50 Hz AC supply with IP 55 class of protection for enclosure, horizontal foot mounted type with Class-F insulation, conforming to IS : 325.c. M.S.fabricated Common base plate, coupling, coupling guard, foundation bolts etc. As required.d. Suitable cement concrete foundation duly plastered and with anti vibration pads. 180 lpm at 56 m Head 361 Fabrication, supply, Installation testing & commissioning of Electrical control panel of cubical construction, floor mounted type, fabricated out of 2mm thick CRCA sheet, compartmentalised with hinged lockable doors, dust and vermin proof, powder coated of approved shade after 7 tank treatment process, cable alley, inter-connection with suitable size copper conductor cable/solid copper strip, having switchgears and accessories, mountings and internal wiring, earth terminals, numbering etc. complete in all respect, suitable for main fire pump, pressurisation pump & diesel pump set complete as per CPWD specification with following in coming and Outgoings, suitable for operation on 415V, 3 phase, 50Hz Ac Supply with enclosure protection class IP 42 as required :INCOMING 250A, 50kA 4 Pole MCCB, Ics=100% Icu rating Digital Voltmeter 0-500V with selector switch Digital Ammeter (0-250 A) with selector switch & CTs etc. LED type RYB phase indicating lamps, ON, OFF, trip indicating lamps Set of Copper Bus Bar 300A OUTGOING (Note : All outgoing feeders for pumps should have digital Ammeter with selector switches, and LED type ON, OFF, trip indicating lamps)Main Fire Pump125 A, 50kA TPN MCCB, Ics=100% Icu, with fully automatic Star/Delta starter suitable for 60 HP pump with overload protection, current sensing type single phase preventor complete with all accessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation.Jockey Pump63 A, 50kA TPN MCCB, Ics=100% Icu, with suitable HP fully automatic Star/Delta starter with overload protection, current sensing type single phase preventor complete with all accessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation.DIESEL ENGINE CONTROLControl for diesel engine comprising - Automatic/Manual selector switch & 3 attempts starting device, timers and relays as required, push buttons, start/stop in manual mode Indicating lamp for high/ Low Lub. Oil pressure, High Water Temp and Engine on indication Battery charger suitable for 12V/24 V DC with boost and trickle selector switch, 0-30 V DC volt meter, and 0- 20 A DC Ammeter All standard relays and accessories for automatic operation of diesel engine System Controller.Designing, Supply, Installation, Testing and commissioning of system controller to control operation of main electric fire pump, diesel pump, Pressurization pump, Terrace pump in sequence as per specification consisting of relays, timers. Sensors, annunciation window for fault indication, complete as per specification 362 Supplying & Installation of suitable flexible coupling/connection to fix at the suction and deliverys side of the fire pumps.dia 150mm 363 Supplying & Installation of suitable flexible coupling/connection to fix at the suction and deliverys side of the fire pumps.dia 80mm 364 Supply and Installation of 12V DC, 200Ah maintenace free battery suitable for Diesel Engine driven fire pump operation with required connect cable set, battery stand. 365 Supplying & Installation of suitable flexible coupling/connection to fix at the suction and deliverys side of the fire pumps.dia 100mm 366 Signages 367 Supply and fixing in position Exit Signages photo luminescent type with indication arrows and letters Exit/Fire Exit/ Staircase/FIRE/Fire Station/Fire Fighting Equipment/Fire Duct/ Fire Extinguisher/ Floor/Fire Command Centre/Fire Pump Room/ No Smoking / Danger/ Call point / Sounder Identification Numbers (Ground/ 1st/2nd)/ In case of the fire do not use lift, use stairs and other mandatory signages recommended by Fire Departments having dimension 30 cm x 15 cm complete inculding fixing mechanism. 368 Supplying and Installing in position the signages approved by Kerala state fire service - of minimum size 1ft x 1.5ft made out of PVC rigid sheet 3mm thick with computer cut PVC non- reflective self adhesive imported vinyl painted on the front of PVC rigid sheet complete with wall mounting arrangements with mirror screws. with lettering- ASSEMBLY AREA 369 Signboards: Supply and Installation of Fire Escape Plan with fire fighting equipment location, exit in A3 Foam sheet with plastic lamination with necessory accessories to fix it on wall. 370 Supply and fixing in position & Fire Order& signage in suitable size made of high quality PVC foam sheet with photo luminescent lamination to make it glow automatically in the dark, with suitable arrangement to fix it on wall. 371 Supplying & fixing in position Assembly Point sigange in suitable size on aluminium composite panel with suitable stand to fix it on open area outside building. Assembly Point 372 Terrace pump 373 Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump)a.Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical confirming to IS : 1520b. Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horiziontal foot mounted type with Class-F insulation, conforming to IS-325.c. M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required.d. Suitable cement concrete foundation duly plastered and with anti vibration pads. 450 lpm at 35 m Head 374 Design, Supply, Installation, Testing, and Commissioning of an Automatic Terrace Fire Pump Panel, including:- IP54-rated enclosure with powder-coated CRCA sheet steel.- 32A 16kA MCCB, 15 HP-rated pump 3P contactor, overload relay, and pressure switch for automatic pump operation.- Auto/Manual selector switch, START/STOP push buttons, hooter, timer, and protection features (dry-run, phase failure, etc.).- Indicators (Power ON, Pump Running, Fault, Low Pressure), meters (Voltmeter, Ammeter with selector switches).- Copper wiring, termination, and provision for cable glands.- Installation, onsite calibration, and full functional testing for pressure-based automation. 375 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 16 sq mm with factory made clamp 376 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm) 377 Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required100 mm dia 378 Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :100mm dia 379 Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange.100mm dia 380 Pressure Guage-Supply, Installation, Testing and Commissioning of pressure guage, 4 & dial, 0 - 200 psi range 3/8 BSP weather proof with stainless steel internals, siphon tube including fittings etc (UL Listed). Make: H Guru/Pointer 381 Supply, installation, Testing and Commissioning of Lever operated Ball valves made of Cast iron conforms to IS 5312, at required locations (UL Listed).20 mm dia Make : Kartar/ Atom 382 Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required4.00 mm copper conductor ( 8 SWG) 383 Supply of superior quality copper tubular cable socket and making core termination of cables of the following sizes including crimping etc. as required.10 sq mm 384 Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required 385 Above Ground Piping 386 Providing, laying, testing & commissioning of C class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :100 mm dia 387 Providing, laying, testing & commissioning of C class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :25 mm dia 388 Providing, laying, testing & commissioning of C class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :80 mm dia 389 Providing, laying, testing & commissioning of C class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :250 mm dia (wall thickness 6.3 mm) 390 Providing, laying, testing & commissioning of C class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :150 mm dia 391 Providing, laying, testing & commissioning of C class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :200 mm dia (wall thickness 6.3 mm) 392 Supply and Installation of 80mm dia M.S. &C& Class Diesel Engine exhaust pipe duly insulated with 50mm thick Glass wool with 1mm thick aluminium sheet cladding with bellows, flexible joint, necessary support, making hole in brick wall for pipe installation.Pipe dia 80mm 393 Underground piping 394 Supply, Installation, Testing and Commissioning of MS C class ERW pipes with ISI Mark complete including cutting and jointing as per the requirements of standards, welding using high quality welding electrodes for pipe. supporting the pipes using Channels or Angles or structures at required intervals as specified for fire fighting work. Piping shall have one coat of anticorrossive zinc chromate industrial primer and two coats of IS approved colour code. All pipes are with ISI mark (IS 1239/3589)Pipes of required dimensions (length and dia) need to fabricated by the vendor by cutting/welding pipes of standard dimensions. length of each type( pipe diameter) should be fixed by the vendor after visiting the site and factory building. The pipe shall be laid direct in ground (75 cm below ground level) including excavation and refilling the trench and covering with 3 mm tar sheet. Pipe size 150 mm. Make - TATA / JINDAL 395 Supply, Installation, Testing and Commissioning of MS C class ERW pipes with ISI Mark complete including cutting and jointing as per the requirements of standards, welding using high quality welding electrodes for pipe. supporting the pipes using Channels or Angles or structures at required intervals as specified for fire fighting work. Piping shall have one coat of anticorrossive zinc chromate industrial primer and two coats of IS approved colour code. All pipes are with ISI mark (IS 1239/3589)Pipes of required dimensions (length and dia) need to fabricated by the vendor by cutting/welding pipes of standard dimensions. length of each type( pipe diameter) should be fixed by the vendor after visiting the site and factory building. The pipe shall be laid direct in ground (75 cm below ground level) including excavation and refilling the trench and covering with 3 mm tar sheet. Pipe size 200 mm. Make - TATA / JINDAL 396 Supply, Installation, Testing and Commissioning of MS C class ERW pipes with ISI Mark complete including cutting and jointing as per the requirements of standards, welding using high quality welding electrodes for pipe. supporting the pipes using Channels or Angles or structures at required intervals as specified for fire fighting work. Piping shall have one coat of anticorrossive zinc chromate industrial primer and two coats of IS approved colour code. All pipes are with ISI mark (IS 1239/3589)Pipes of required dimensions (length and dia) need to fabricated by the vendor by cutting/welding pipes of standard dimensions. length of each type( pipe diameter) should be fixed by the vendor after visiting the site and factory building. The pipe shall be laid direct in ground (1m below ground level) including excavation and refilling the trench and covering with 3 mm tar sheet. Pipe size 100 mm. Make - TATA / JINDAL 397 Valves, measuring devices & switches 398 Supplying, fixing, testing & commissioning of double flanged sluice valve of rating PN 1.6 with non rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 780 of following sizes as required:200mm dia 399 Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required80 mm dia 400 Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required100 mm dia 401 Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required150 mm dia 402 Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :80mm dia 403 Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :150mm dia 404 Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange.150mm dia 405 Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and painting with synthetic enamel paint of approved shade as required. 406 Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required 407 Pressure Gauge-Supply, Installation, Testing and Commissioning of pressure gauge, 4 dial, 0 - 200 psi range 3/8 BSP weather proof with stainless steel internals, siphon tube including fittings etc (UL Listed). Make: H Guru/Pointer 408 Supply and fixing of Air release valve Brass body of 25 mm dia (UL Listed) following IS standards, with required pressure rated. 409 Supply, installation, Testing and Commissioning of Lever operated Ball valves made of Cast iron conforms to IS 5312, at required locations.25 mm dia Make : Kartar/ Atom 410 Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :100mm dia 411 MOEFA system, Automatic Detection & Fire Alarm System 412 Supplying, installing, testing and commissioning approved make Microprocessor based Multi-loop, Networkable Addressable Fire Alarm Control Panel with minimum 600 characters LCD display, 4000 trouble events including1000 alarm log history events, Self Programmable alphanumeric keypad for programming. The panel should be equipped with sufficient numbers of loops considering 20% spare capacity in each loop and shall be extendable upto 10 Loops. Each loop shall have a capacity of minimum 125 detectors & 125 other devices exculding 20% spare. The panel shall work in degrade mode in case of CPU failure, Products not having this feature may offer Redundant CPU. Four access levels, flash EPROM, 240 volts AC power supply, automatic battery charger, 24 volts sealed lead acid batteries sufficient for 24 hours normal working and 30 mins in alarm condition with the charging capacity of 200AH. The panel shall be capable of self programing without any dependancy on dongle or programming software. Quoted rate shall include supply of necessary software & hardware for progamming the panel with all necessary licence. Panel shall have Modbus over IP protocol for future integration with BMS. However, for present arrangement FA system will be standalone with 24x7 monitoring. The panel shall be capable of connecting to the cloud platform/solution. Complied to meet UL864, 10th Edition 6 Loop Networkable Addressable Fire Alarm Control Panel(Make: Honeywell or Equivalent) 413 Supplying, installation, testing & commissioning of addressable fire control module complete as required. 414 Supplying, installation, testing & commissioning of addressable manual call point complete as required. 415 Supplying, installation, testing & commissioning of addressable horn cum strobe complete as required. 416 Supplying, installation, testing & commissioning of intelligent analog addressable photothermal detector complete with mounting base complete as required. 417 Supplying, installation, testing & commissioning of fault isolator complete with base as required. 418 Supplying, Installation, testing & commissioning of external power supply unit provides regulated and filtered 24 VDC power for hooter operation.Battery backup with built in charging. 419 CABLING & WIRING Supplying & laying of 2x1.5 sq mm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required. 420 Miscellaneous 421 Preparation of initial and final drawings, submission to Panchayath, Municipality, KSEB, Electrical Inspectorate, Kerala Water Authority, State Pollution Control board, Fire Department, Factories and Boilers and other agencies if any for getting approval, sanction and No Objection Certificate for building permit and completion from Fire Department and other department. Quoted rate shall be excluding statutory fee (All statutory fees shall be borne by Client-actual statutory fees shall be reimbursed on submission of original bill/challans from authorities).
Contract Date: Jul 17, 2025 Contract Value : 11.48 Crore
Boards / Undertakings / PSU No of Bidders 1
6.
Public Administrative Department #10379186 Price Bid
Supply, Installation, Testing, Commissioning And Maintenance For Cctv Camera Surveillance System And Integrated Command Control ( Iccc ) Surveillance System For Palghar Muncipal Conucil Area 58 Cameras And 3 Year Amc ( Semi-Comprehensive Service And M , Supply, Installation, Testing, Commissioning And Maintenance For Cctv Camera Surveillance System Andintegrated Command Control ( Iccc ) Surveillance System For Palghar Muncipal Conucil Area 58 Cameras And 3 Year Amc ( Semi-Comprehensive Service And Maintenance Contract 3 Years ) . Palghar. , Supply, Installation, Testing & Commisioning Of 5Mp Bullet Camera Image Sensor 1 / 2.9 Progressive Scan Cmos Min. Illumination Color: 0.01 Lux @ ( F1.2, Agc On ) , 0.028 Lux @ ( F2.0, Agc On ) , 0 Lux With Ir Shutter Speed 1 / 3 S To 1 / 100, 000 S Slow Shutter Yes Day & Night Ir Cut Filter Digital Noise Reduction 3D Dnr Wdr 120Db 3-Axis Adjustment Pan: 0° To 360°, Tilt: 0° To 100°, Rotate: 0° To 360° Focal Length 2.8 / 4 / 6 / 8 Mm Aperture F2.0 Focus Fixed Fov 2.8 Mm, Horizontal Fov: 97°, Vertical Fov: 63°, Diagonal Fov: 120° 4 Mm, Horizontal Fov: 78°, Vertical Fov: 50°, Diagonal Fov: 97° 6 Mm, Horizontal Fov: 60°, Vertical Fov: 39°, Diag Onal Fov: 75° 8 Mm, Horizo Ntal Fov: 39.5°, Vertical Fov: 26°, Diagon Al Fov: 48° Lens Mount M12 Ir Range Min 50 M Wavelength 850Nm Video Compression Main Stream: H.265 / H.264 Sub-Stream: H.265 / H. 264 / Mjpeg Third Stream: H.265 / H.264 H.264 Type Main Profile / High Profile H.264+ Main Stream Supports H.265 Type Main Profile H.265+ Main Stream Supports Video Bit Rate 32 Kbps To 16 Mbps. Smart Event Line Crossing Detection, Intrusion Detection, Face Detection Basic Event Motion Detection, Video Tampering Alarm, Exception ( Network Disconnected, Ip Address Conflict, Illegal Login, Hdd Full, Hdd Error ) Linkage Method Trigger Recording: Memory Card, Network Storage, Pre-Record And Post-Record Trigger Captured Pictures Uploading: Ftp, Http, Nas, Email Trigger Notification: Http, Isapi, Email Region Of Interest Support 1 Fixed Region For Main Stream And Sub-Stream Max. Resolution, 25 Fps In All Resolution 30Fps ( 2560 × 1440, 1920 × 1080, 1280 ×720 ) Sub-Stream 50Hz: 25Fps ( 640 × 480, 640 × 360, 320 × 240 ) 60Hz: 30Fps ( 640 × 480, 640 × 360, 320 × 240 ) Third Stream 50Hz: 25Fps ( 1280 × 720, 640 × 360, 352 × 288 ) 60Hz: 30Fps ( 1280 × 720, 640 × 360, 352 × 240 ) Image Enhancement Blc / 3D Dnr / Hlc Image Setting Rotate Mode, Saturation, Brightness, Contrast, Sharpness, Agc, And White Balance Are Adjustable Byclient Software Or Web Browser Target Cropping No Day / Night Switch Day / Night / Auto / Schedule Network Storage Support Micro Sd / Sdhc / Sdxc Card ( 128G ) , Local Storage And Nas ( Nfs, Smb / Cifs ) , Anr Protocols Tcp / Ip, Udp, Icmp, Http, Https, Ftp, Dhcp, Dns, Ddns, Rtp, Rtsp, Rtcp, Pppoe, Ntp, Upnp, Smtp, Snmp, Igmp, 802.1X, Qos, Ipv6, Udp, Ssl / Tls General Function Anti-Flicker, Three Streams, Heartbeat, Mirror, Privacy Masks, Password Reset Via E-Mail, Pixel Counter, Http Listening Security Password Protection, Complicated Password, Https Encryption, 802.1X Authentication ( Eap-Tls 1.2, Eap-Leap, Eap-Md5 ) , Watermark, Ip Address Filter, Basic And Digest Authentication For Http / Https, Wsse And Digest Authentication For Onvif, Tls1.2Api Onvif ( Profile S, Profile G, Profile T ) , Isapi, Sdk Simultaneous Live View Up To 6 Channels User / Host Up To 32 Users 3 Levels: Video Output No Communication Interface 1 Rj45 10M / 100M Self-Adaptive Ethernet Port On-Board Storage Built-In Microsd / Sdhc / Sdxc Slot, Up To 128 Gb Svc H.264 And H.265 Encoding Support Reset Button Yes Operating Conditions -30 °C To +60 °C ( -22 °F To +140 °F ) , Humidity 95% Or Less ( Non-Condensing ) Power Supply 12 Vdc ± 25%, F 5.5Mm Coaxial Power Plug Poe ( 802.3Af, Class 3 ) Power Consumption And Current :12 Vdc, 0.6 A, Max. 7 W Poe: ( 802.3Af, 36 V To 57 V ) , 0.3 A To 0.2 A, Max. 8.5 W Max. 12 W Protection Level Ip67. Warranty Of 1 Year. , Supply, Installation, Testing & Commisioning.Of 5Mp Bullet Camera. Image Sensor-1 / 2.7 Cmos, Max. Resolution-2592 ( H ) × 1944 ( V ) , Rom-128 Mb, Ram-512 Mb, Scanning System Progressive Electronic Shutter Speed Auto / Manual 1 / 3 S–1 / 100, 000 S Min. Illumination 0.005 [email protected] ( Color, 30 Ire ) 0.0005 [email protected] ( B / W, 30 Ire ) 0 Lux ( Illuminator On ) S / N Ratio>56 Db Illumination Distance-60 M ( 196.85 Ft ) ( Ir Led ) Illuminator On / Off Control Auto;Manual Illuminator Number 4 ( Ir Led ) , Pan / Tilt / Rotation Range Pan: 0°–360° Tilt: 0°–75° Rotation: 0°–360° Lens Type Motorized Vari-Focal Lens Mount F14 Focal Length-2.7 Mm–13.5 Mm, Max. Aperture-F1.5 Field Of View H: 100°–30° V: 72° –23° D: 134° –38° Iris Control-Fixed Close Focus Dista Nce-0.8 M ( 2.62 Ft ) Dori Distance Lens Detect Observe Recognize Identify W 64.4 M ( 211.29 Ft ) 25.8 M ( 84.65 Ft ) 12.9 M ( 42.32 Ft ) 6.4 M ( 21.00 Ft ) T221.4 M ( 726.37 Ft ) 88.6 M ( 290.68 Ft ) 44.3 M ( 145.34 Ft ) 22.1 M ( 72.51 Ft ) Ivs ( Perimeter Protection ) Tripwire; Intrusion ( The Two Functions Support The Classification And Accurate Detection Of Vehicle And Human ) Smart Search-Work Together With Smart Nvr To Perform Refine Intelligent Search, Event Extraction And Merging To Event Videos.Video Compression 25 Fps In All Resolution Bit Rate Control Cbr / Vbr Video Bit Rate H.264: 3 Kbps–8192 Kbps H.265: 3Kbps–8192 Kbps Day / Night Auto ( Icr ) / Color / B / W Blc Yes Hlc Yes Wdr 120 Db Scene Self-Adaptation ( Ssa ) Yes White Balance Auto; Natural; Street L Outdoor; Manual; Regional Custom Gain Control Auto;Manual Noise Reduction 3D Dnr Motion Detection Off / On ( 4 Areas, Rectangular ) Region Of Interest ( Roi ) Yes ( 4 Areas ) Smart Illumination Yes Image Rotation 0° / 90° / 180° / 270° ( Support 90° / 270° With 1080P Resolution And Lower ) Mirror Yes Privacy Masking 4 Areas. Audio Compression G.711A; G.711Mu; Pcm; G.726 ( Only - Zas Supports ) . Alarm Event -Zas:No Sd Card; Sd Card Full; Sd Card Error; Network Disconnection; Ip Conflict; Illegal Access; Motion Detection; Video Tampering; Intrusion; Tripwire; Scene Changing; Audio Detection; Voltage Detection; Defocus Detection; External Alarm; Smd; Safety Exception-Zs:No Sd Card; Sd Card Full; Sd Card Error; Network Disconnection; Ip Conflict; Illegal Access; Motion Detection; Video Tampering; Intrusion; Tripwire; Scene Changing; Voltage Detection; Defocus Detection; Smd; Safety Exception. Network Port Rj-45 ( 10 / 100 Base-T ) Sdk And Api Yes Cyber Security Video Encryption; Firmware Encryption; Configuration Encry Ption; Digest; Wsse; Account Lockout; Security Logs; Ip / Mac Filtering; Generation And Importing Of X.509 Certific Ation; Syslog; Https; 802.1X; Trusted Boot; Trusted Exec Ution; Trusted Upgrade Network Protocol Ipv4; Ipv6; Http; Tcp; Udp; Arp; Rtp; Rtsp; Rtcp; Rtmp; Smtp; Ftp; Sftp; Dhcp; Dns; Ddns; Qos; Upnp; Ntp; Multicast; Icmp; Igmp; Nfs; Samba; Pppoe; Snmp Interoperability Onvif ( Profile S / Profile G / Profile T ) ; Cgi; P2p; Milestone; Genetec User / Host 20 ( Total Bandwidth: 64 M ) Storage Ftp; Sftp; Micro Sd Card ( Support Max. 256 Gb ) ; Nas Browser Ie Chrome, Firefox Management Software Smart Pss; Dss; Dmss Mobile Client-Ios; Android.Audio Input 1 Channel ( Rca Port ) ( Only - Zas Supports ) Audio Output 1 Channel ( Rca Port ) ( Only - Zas Supports ) Alarm Input 1 Channel In: 5 Ma 3–5 Vdc ( Only - Zas Supports ) Alarm Output 1 Channel Out: 300 Ma 12 Vdc ( Only - Zas Supports ) Power Supply 12 Vdc / Poe ( 802.3Af ) Power Consumption Basic: 3.3 W ( 12 Vdc ) ; 4.2 W ( Poe ) Max ( Wdr + Ir Intensity + Intelligence On ) : 7.8 W ( 12 Vdc ) ; 9.7 W ( Poe ) Environment Operating Temperature –30 °C To +60 °C ( –22 °F To +140 °F ) Operating Humidity =95% Storage Temperature–40 °C To +60 °C ( –40 °F To +140 °F ) Protection Ip67.Warranty Of 1 Year. , Supply & Installation Of Camera Housing For Outdoor Suitable For High Temperature Environment, Working Temperature- 20? ~ +60?, Humidity 95% Or Less ( Non-Condensing ) , Main: Aluminum Alloy Window: Glass, Dimension ( Mm ) -455.3×169.2×110, Protection Level-Ip67. , Supply & Installation Of Camera Bracket Mount With Bracket Type: Pan Tilt Brackets, Dimensions Mm: 190 X 200 X 500 Mm, Max Load Kg-50, Housing Material-Steel. , Supply, Installation, Testing & Commisioning. 4 X 100M Poe Ports, 1 X 1000M Rj45 Port, And 1 X 1000M Sfp Fiber Optical Port. Supports Ieee 802.3At / Af. Supports Ieee 802.3, Ieee 802.3U And Ieee 802.3X.Supports High Priority Ports. Supports 8-Core Power Supply. Up To 250 M Transmission Distance. Poe Port With 6 Kv Surge Protection.Supports Poe Output Power Management. 1000M Network Access.Wire-Speed Forwarding And Non-Blocking Design.Store-And-Forward Switching.Solid High-Strength Metal Shell.Power Supply Specification 100~240 Vac, 50 / 60 Hz, Max. 2.5 A. Warranty Of 1 Year. , Supplying And Laying Of Cat-6 Cable With Rodent Proof And Anti Termite Jacket Suitable For Networking As Per Specification No. Wg-Coc / Nc , Supplying And Laying Of Cat-6 Armoured Cable With Eccs Tape Suitable For Networking As Per Specification No. Wg-Coc / Nc , Supply, Installation, Testing & Commisioning. 128G 128Gb Microsd Cards For Surveillance 128 Gb Maximum Read Speed: 96 Mb / S Maximum Read Speed: 96 Mb / S Compatible With Microsdhc, Microsdxc, Microsdhc Uhs-I, And Microsdxc Uhs-I Host Devices. Warranty Of 1 Year. , Supply, Installation & Testing Of 6 U Outdoor Rack Item Type Technical Parameter Layout & Mounting One Compartment, Pole & Wall Mountable Equipment Installation Method 19” Standard Rack Door With One Front Door With Lock ( Support Padlock ) Material 1.Galvanized Steel;2.Single Wall, Thickness Of : 1.2Mm, Thickness Of Mounting Angles:1.5Mm Structure Assembled, Welded Constructions, Ingress Protection Ip65 Temperature Control Cooling Ac220v 90 Cfm Dual Fan.Lighting Led Lamp Ac230 V Or Dc 48V Led Lamp- Optional Temperature Temperature Working Temperature: -40°C ~ +55°C Storage Temperature: -50°C ~ + 70°C Transport Temperature: -50°C ~ +70°C Humidity Relative Humidity 5% ~ 100% Pressure Air Pressure 62Kpa ~ 101Kpa ( Similar To 0M ~ 5000M Altitude ) Radiation Intensity Solar Radiation Intensity 1124 × ( 1±5% ) W / M2 ) Warranty For 1 Year. , Supply, Installation, Testing & Commisioning. Media Converter, Auto-Negotiation Of Half-Duplex / Full-Duplex Transfer Mode Extends Fiber Distance Up To 15Km.1× 1000M Sc / Upc Port 1× 10 / 100 / 1000M Rj45 Port ( Auto Mdi / Mdix ) . Single-Mode Fiber, Utp Category 5, 5E Cable ( Maximum 100M ) Eia / Tia-568 100O Stp ( Maximum 100M ) .Operating Temperature: 0?~50? ( 32?~122? ) . Warranty Of 1 Year. , Supplying And Erecting Lszh Armoured Multimode Optical Fibre Cable With 12 Fibres, Core Dia 50 / 125 ?M ( Om3 ) , Suitable Up To 10 Gbps Ethernet Distance At 850 Nm Of Wavelength, On Wall / Ceiling Or Laid In Provided Pipe / Trench As Per Specification No. Wg-Coc / Ofc , Providing & Erecting 5 M High ( Clear Height ) Galvanised Octagonal Pole With Foundation Bolts Having Bottom Of 130 Mm A / F, Top 70 Mm A / F On Provided Foundation As Per Specification No. Oh-Pl / Opl. , Making M- 20 Grade Reinforced Cement Concrete Foundation By Considering The Safe Soil Bearing Capacity As 10 T / Sq.M At 1.5 M Depth Including Supply Of Steel, Concrete, Excavation, Fixing Provided Nut Bolts With The Help Of Template, Duly Plastered As Per Design Complete ( For 3 To 5M Octagonal / Conical Gi Pole ) . , Supply, Lnstallation, Testing & Commissioning Of Nvr Viewer Workstation ( Hp / Dell / Lenovo ) With Duel Monitor Support , With Nvr Viewer Software And License Operating System 12Th Gen Lntel Corerm I5- Processor Windows 10 Pro ( Windows 1 1 Pro License Included ) , English8 Gb, Ddr5, 256 Gb, M.22230, Pcle Nvme, Ssd, Class 35 Power Button; Hard Disk Drive Activity Light ;. Line Ln / Out 4. Universal Audio Jack S.Usb 3.2 Gen 2Type A With Power Share 6. Usb 3.2 Gen2x2 Type C ( 20Gb Data ) Back ( 35W ) : Knock-Out Slot For External Wireless Antenna ( Optional ) ; Optional Video Port ( Hdmi 2.0B1 Displayport 1.4A1 Vga / Usb Type-C With Displayport Alt Mode ) ; Usb 3.2 Type A Ports ( 2 - One With Power On ) ; Padlock Ring And Kensington Security Cable Slot ; Ethernet Rj-45 12. Usb 3.2 Gen 2 Type A Ports ( 2 ) ; Display Ports 1.A ( 1 ; Power Adapter Portback ( 65W ) : ; Knock-Out Slot For Wireless Antenna ; Optional Video Port ( Hdmi 2.0Bl Displayport 1.4A1 Vga / Usb Type-C With Displayport Alt Mode ) ; Usb 3.2 Gen 1 Type A With Smart Power On; Padlock Ring And Kensington Security-Cable Slot ; Ethernet Rj-45; Usb 3.2 Gen 2 Type A Ports ( Z ) ; Displayport 1.4 Ports ( 3 ) ; Power Adapter Port.Warranty Of 1 Year. , Supplying, Erecting, Testing And Commissioning Of 3Kva Capacity Online Pure Sine Wave With Backup Time Of ....... Hrs. Pwm & Igbt Based Ups With 0.8 To Unity Output Pf, Single Phase Input & 1 Phase Output Complete With All Protections As Per Specification No. Ap-Ups. Warranty Of 1 Year. , Supplying And Erecting 12 V / 65Ah Smf Battery With Battery Terminal Wire, Duly Charged Complete With 24 Months Warranty Complete. Warranty Of 1 Year. , Supply, Installation Testing And Commissioning Of Router - Cable Or Dsl Modem With Ethernet Port, 4 10 / 100 Lan Ports, 1 10 / 100 Wan Port, 2.4 Ghz To 2.497 Ghz, Wep 64 / 128-Bit Data Encryption, Wi-Fi Protected Access ( Wpa / Wpa2 ) , Wps, Network Address Translation ( Nat ) , Stateful Packet Inspection ( Spi ) , Mac Address Filtering, Url Filtering, Power, Internet Status, Wlan , Lan.Warranty Of 1 Year. , Supply, Installation, Testing & Commisioning. Uhd 4K Led Display 86 Interactive Panel With Resolution Of 3840 × 2160 ? Anti-Glare And Anti-Blocking Design To Ensure Smooth Interaction? Dual Systems Of Windows And Android Saving Cost And Easy To Use? Quick Response, At Most 20-Point Touch Control And Smooth Writing Experience? Dual Usb 3.0 Interfaces, And Data From Any Interface Can Be Read In Windows And Android System At The Same Time? Enable The Floating Ball By Gesture To Realize Writing, Erasing, Screenshoting And Freezing In Any Channel? Mirroring By Mobile Phone Or Tablet To Realize Remote Control And Flexible Teaching? Teaching Software Integrating Kinds Of Tools And Materials, Convenient Writing, Erasing, Recording, Preparing And Teaching ? Scan The Qr Code To Save The Teaching Notes ? All-In-One Design With Tempered Glass And Intelligent Temperature Control, Making It Environmental-Friendly And Safety-Guaranteed.Warranty Of 1 Year. , Supply Installation & Testing Ofvms, An Integrated Security Software, Is Designed To Meet Versatile Security Challenges In One Intuitive Platform: From Managing Individual Systems Such As Video Security, Access Control, Intrusion Alarm, Etc., To Collaborating Multiple Systems Under A Unified Architecture. While Protecting People And Property, It Makes Daily Operations More Efficient, And Helps Various Kinds Of Users Make Smarter Decisions. , Supply, Installation And Testing Of 10 Tb Surveillance Storage Hard Disk Drive -24R Surveillance Hdo Capacity - 8 Tb Interface Sata Iii 6 Gb / S Max Sustained Transfer Rate Od-210 Mbs Cache - 256 Mb Tamish Resistant Load / Unloadcycles-300 000 Power On Hours / Year 8760 Mean Tim Between Failures ( Mtbf ) - 1 Million Hours Operating Temperature - Ambient : 41 F / 5 C ( Min ) Drive Case : 158 F / 70 C ( Max ) Non Operating Temperature Ambient : 40 F / 10C ( Min ) . Warranty Of 1 Year. , Supply, Installation Testing And Commissioning Of 21 U Rack Rack Standard : Conforms To Din 41494 Or Equivalent Standardconstruction : Welded Or Ckd ( Knockdown ) Front Door : Lockable Double Toughened Glass Door Or Perforated Basic Frame : Steel Equipment Mounting : Din Standard 10Mm Sq. Slots / Direct M6 Tapmounting Angle : 19” Mounting Angles Made Of Formed Steelstandard Finish : Powder Coatedtop And Bottom Cover : Welded To Frame, Vented And Cable Entry / Exit Cut Outs From Top & Bottom Standard Mounting Option : Castor Wheels ( Front 2 Wheels With Break And Rear Without Break ) Or Levelers Standard Color : Grey Or Black Static Load : 500Kgs. Warranty Of 1 Year. , Supply, Installation Testing And Commissioning Of 8 Port Poe Later 2 Indoor Network Switches With 2 Sfp Port And Modules Complete As Required. 3 Years Defect Liability Period, All Necessary Maintenance, Transportation, Rack And Taxes.Warranty Of 1 Year. , Supply, Installation Testing And Commissioning Of Nvr For Video And Audio Ip Video Input 64-Ch Up To 12 Mp Resolution*: 32 Mp And 24 Mp Is Only Available For Channel 1 When Ultra Hd Resolution Mode Is Enabled. Incoming Bandwidth 320 Mbps Outgoing Bandwidth 256 Mbps Incoming Bandwidth ( Raid Mode ) 200 Mbps Outgoing Bandwidth ( Raid Mode ) 200 Mbps Hdmi 1 Output 4K ( 3840 × 2160 ) / 60Hz, 4K ( 3840 × 2160 ) / 30Hz, 1920 × 1080 / 60Hz, 1600 × 1200 / 60Hz, 1280 × 1024 / 60Hz, 1280 × 720 / 60Hz, 1024 × 768 / 60Hz Hdmi 2 Output 1920 × 1080 / 60Hz, 1280 × 1024 / 60Hz, 1280 × 720 / 60Hz, 1024 × 768 / 60Hzvga 1 Output 1920 × 1080 / 60Hz, 1280 × 1024 / 60Hz, 1280 × 720 / 60Hz, 1024 × 768 / 60Hz Vga 2 Output1920 × 1080 / 60Hz, 1280 × 1024 / 60Hz, 1280 × 720 / 60Hz, 1024 × 768 / 60Hz Video Output Mode Hdmi 1 And Vga 1 Provide Simultaneous Video Output, And Work As The Main Output;Hdmi 2 And Vga 2 Provide Simulta Neous Video Output, And Work As The Auxiliary Output Cvbs Output 1-Ch, Bnc ( 1.0 Vp-P, 75 O ) , Resolution: Pal: 704 × 576, Ntsc: 704 × 480 Audio Output2-Ch, Rca ( Linear, 1 K? ) Two-Way Audio1-Ch, Rca ( 2.0 Vp-P, 1 K?, Using The Audio Input ) Decoding Decoding Format H.265+ / H.265 / H.264+ / H.264 / Mpeg4 Recording Resolution 32 Mp / 24 Mp / 12 Mp / 8 Mp / 6 Mp / 5 Mp / 4 Mp / 3 P / 1080P / Uxga / 720P / Vga / 4Cif / Dcif / 2Cif / Cif / Qcif *: 32 Mp And 24 Mp Is Only Available For Channel 1 When Ultra Hd Resolution Mode Is Enabled. Synchronous Playback 16-Ch Decoding Capability 1-Ch@32 Mp ( 30 Fps ) / 2-Ch@12 Mp ( 20Fps ) / 4-Ch@8 Mp ( 25Fps ) / 8-Ch@4 Mp ( 30Fps ) / 16-Ch@1080P ( 30Fps ) Dual-Stream Recording Support Stream Type Video, Video & Audio Audio Compression. 711Ulaw / G.711Alaw / G.722 / G. 726 / Aac / Mp2l2 / Pcm Network Remote Connection 128 Network Protocoltcp / Ip, Dhcp, Ipv4, Ipv6, Dns, Ddns, Ntp, Rtsp, Sadp, Smtp, Snmp, Nfs, Iscsi, Isup, Upnp™, Http, Https Network Interface 2, Rj-45 10 / 100 / 1000 Mbps Self-Adaptive Ethernet Interface Raid Raid Type Raid0, Raid1, Raid5, Raid6, And Raid10 ( At Least 4 Tb For Each Hdd ) Auxiliary Interface Serial Interface 1 Rs-485 ( Full-Duplex ) , 1 Rs-232, 1 Keyboard, 10 Sata Interfaces Supporting Hot-Plug Esata 1 Esata Interface Capacity-Up To 10Tb Capacity For Each Disk. Alarm In / Out-16 / 4. Usb Interface Front Panel: 2 × Usb 2.0; Rear Panel: 1 × Usb 3.0 Power Supply-100 To 240 Vac, 50 To 60 Hz Consumption-30 W Working Temperature-10 °C To 55 °C ( 14 °F To 131 °F ) Working Humidity 10% To 90% Chassis 3U Weight-10 Kg ( 22 Lb ) .Warranty Of 1 Year. , Supplying, Installing And Testing Utp Connector ( Rj-45 ) As Per Specification No.Wg-Nas / Utpc. , Amc ( Semi-Comprehensive ) Forcamera Complete Solution From On Field Equipments To Command Control Setup For 2Nd Year Where Upto Rs.1000 Will Be Waived Off Or Bare By Agency.From Agency Twice Inspection Will Be Done In A Month And Camera Position And Working Status Of Camera Will Be Updated. ( Parts Includes In Semi Comprehensive Amc Are Camera, Poe Switch, Tv, Work Station, Memory Card, Nvr, Inverter & Batteries ) . , Amc ( Semi-Comprehensive ) Forcamera Complete Solution From On Field Equipments To Command Control Setup For 3Rd Year Where Upto Rs.1000 Will Be Waived Off Or Bare By Agency.From Agency Twice Inspection Will Be Done In A Month And Camera Positionand Working Status Of Camera Will Be Updated. ( Parts Includes In Semi Comprehensive Amc Are Camera, Poe Switch, Tv, Work Station, Memory Card, Nvr, Inverter & Batteries ) . , Amc ( Semi-Comprehensive ) Forcamera Complete Solution From On Field Equipments To Command Control Setup For 4Th Year Where Upto Rs.1000 Will Be Waived Off Or Bare By Agency. From Agency Twice Inspection Will Be Done In A Month And Camera Position And Working Status Of Camera Will Be Updated. ( Parts Includes In Semi Comprehensive Amc Are Camera, Poe Switch, Tv, Work Station, Memory Card, Nvr, Inverter & Batteries ) . , Add 4% Contigency Rs.
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 5
Maharashtra View Result →
7.
Public Administrative Department #10259911 Price Bid
Improvements of Water Supply System in Thiruporur Town Panchayat- 1 Supply,delivery of DUCTILE IRON SOCKET/SPIGOT PIPES FOR CLASS K7 for potable water supply as per IS specification no. 8329 /2000 and as amended from time to time with ISI marking of the following sizes and for delivery at site including loading, unloading, freight stacking, conveyance to the work site etc., complete as directed by the Engineer-incharge 250mm DI S/S K7 Class Pipe 2 300mm DI S/S K7 Class Pipe 3 350mm DI S/S K7 Class Pipe 4 Supply, delivery of Ductile Iron Specials As Per IS 9523/2000includingunloading, transportation and stacking charges, conveyance to work site etc., complete as directed by the Engineer in charge. DI D/S Specials (250 mm to 300 mm) 5 DI D/S Specials (350 mm to 450 mm) 6 Supply of the following UPVC 6 KSC pipes and specials as per IS specifications for Cable complete as directed by the Engineer in charge. 50 MM UPVC 6 KSC pipe (Power Cable Cover Pipe) 7 Supplying and conveying to site, the following sizes of HDPE pipes of class PN10 (PE-100) confirming to IS:4984/1995, as specified in Technical specifications in standard lengths including labour charges for loading, unloading and stacking at site and transportation charges etc., complete as per standard specifications and as directed by the Engineer in Charge.110mm HDPE PN10 Class Pipe 8 200mm HDPE PN10 Class Pipe 9 Supply, delivery of HDPE Specials As Per IS 1736-1995includingunloading, transportation and stacking charges. Specials for HDPE pipes as per IS 8360/1977/ Part I(Reaffirmed 1992) Part II and III (Reaffirmed 2002). Reaffirmed to IS 4984-2016 conveyance to work site etc., complete as directed by the Engineer in charge. HDPEBends - 90° - PN10 Class 110mm 10 HDPEBends - 90° - PN10 Class - 200mm 11 HDPE Equal Tee - PN10 Class - 110mm x 110mm x 110mm 12 HDPE Equal Tee - PN10 Class 200mm x 200mm x 200mm 13 HDPE PN10 Class Reducer - 200mm x 110mm HDPE Reducer 14 DI D/F Gate Valves with Specials: Supply and Delivery of DI D/F Gate valves (Soft Seated) resilient seated softsealing gate valves (sluice valves) with body bonnet of ductile cast iron of gradeGGG40 or equivalent grade, wedge fully rubber lined with EPDM, replaceable spindlenut, without gland packing and with 3 O-Ring protection on the shaft and seals ofNBR and the valves should be of vaccum tight and 100% leak proof with face toface dimentions as EPR BS 5163-89/ ISI 14846-2000/ DIN 3202 F 4. All the valvesshould be with electrostatic powder coating both inside and outside with pocketless straight thro body passage. All the valves are to be compatible for burriedapplication with pressure rating PN 10/16 and Supply, delivery of Ductile Iron Specials as Per IS 9523/2000including unloading, transportation and stacking charges for fixing of valves with specials including labour charges for lowering, laying,jointing etc complete as directed by Engineer in Charge100 mm DI D/F Gate Valve PN 16 in 100mm DI main with fixing of DI Specials as per IS 9523/2000 including loading, transportation and Stacking Charges as per the following sizes as per the drawing, details of valves and specials as below100 mm DI D/F Gate Valve PN 16 - 1 No 100 D.I.Flg /skt T.P. - 1 No100 D.I.Flg /spgt T.P. - 1 No Jointing the C.I/ D.I Double flanged pipes and specials with rubber insertion to with IS-638(1979) and M.S. bolts and nuts of IS 1364-1 (2002), including cost of jointing materials such as bolt and nuts Rubber insertion and labour charges etc., complete - 2 Nos – 100mmJointing the C.I/ D.I-S/S pipes and specials with neat cement or cement mortar and spun yarn including caulking the joints, curing. (including cost of jointing materials)- 2 Nos- 100 mm 15 200 mm DI D/F Gate Valve PN 16 in 200mm DI main with fixing of DI Specials as per IS 9523/2000 including loading, transportation and Stacking Charges as per the following sizes as per the drawing, details of valves and specials as below 200 mm DI D/F Gate Valve PN 16 - 1 No 200 D.I.Flg /skt T.P. - 1 No 200 D.I.Flg /spgt T.P. - 1 No Jointing the C.I/ D.I Double flanged pipes and specials with rubber insertion to with IS-638(1979) and M.S. bolts and nuts of IS 1364-1 (2002), including cost of jointing materials such as bolt and nuts Rubber insertion and labour charges etc., complete - 2 Nos - 200 mm Jointing the C.I/ D.I-S/S pipes and specials with neat cement or cement mortar and spun yarn including caulking the joints, curing. (including cost of jointing materials)- 2 Nos - 200 mm 16 250 mm DI D/F Gate Valve PN 16 in 250mm DI main with fixing of DI Specials as per IS 9523/2000 including loading, transportation and Stacking Charges as per the following sizes as per the drawing, details of valves and specials as below 250 mm DI D/F Gate Valve PN 16 - 1 No 250 D.I.Flg /skt T.P. - 1 No 250 D.I.Flg /spgt T.P. - 1 No Jointing the C.I/ D.I Double flanged pipes and specials with rubber insertion to with IS-638(1979) and M.S. bolts and nuts of IS 1364-1 (2002), including cost of jointing materials such as bolt and nuts Rubber insertion and labour charges etc., complete - 2 Nos - 250 mm Jointing the C.I/ D.I-S/S pipes and specials with neat cement or cement mortar and spun yarn including caulking the joints, curing. (including cost of jointing materials)- 2 Nos -250 mm 17 300 mm DI D/F Gate Valve PN 16in 300mm DI main with fixing of DI Specials as per IS 9523/2000 including loading, transportation and Stacking Charges as per the following sizes as per the drawing, details of valves and specials as below300 mm DI D/F Gate Valve PN 16 - 1 No - 300 mm DI.Flgd Spgt T.P.-1No 300 mm DI.Flgd Skt T.P.-1No Jointing the C.I/ D.I Double flanged pipes and specials with rubber insertion to with IS-638(1979) and M.S. bolts and nuts of IS 1364-1 (2002), including cost of jointing materials such as bolt and nuts Rubber insertion and labour charges etc., complete - 2 Nos - 300 mm Jointing the C.I/ D.I-S/S pipes and specials with neat cement or cement mortar and spun yarn including caulking the joints, curing. (including cost of jointing materials)- 2 Nos -300 mm. 18 For Pumping Main - Gate Valve with Specials - Scour 80 mm DI D/F Gate valve for Scour in 100 mm DI main with fixing of DI Specials as per IS 9523/2000 including loading, transportation and Stacking Charges as per the following sizes as per the drawing, details of valves and specials as below100 x 100 x 80 mm D.I. D/S B/F Tee - 1 No 80 mm x 2.50 m D.I. D/F- 1 No 80 mm x 1.0 m D.I. D/F Pipe - 2 Nos 80 mm DI D/F Gate Valve - 1 No. 80 mm D.I. D/f DFoot bend - 1 No 80 mm DI D/F 90˚ Bend - 2 No Surface box - 1 No. Jointing the C.I/ D.I Double flanged pipes and specials with rubber insertion to with IS-638(1979) and M.S. bolts and nuts of IS 1364-1 (2002), including cost of jointing materials such as bolt and nuts Rubber insertion and labour charges etc., complete - 8 Nos - 80 mm Jointing the C.I/ D.I-S/S pipes and specials with neat cement or cement mortar and spun yarn including caulking the joints, curing. (including cost of jointing materials)- 2 Nos - 100 mm 80 mm DI Flanged / SPKT TP - 1 No Jointing the C.I/ D.I-S/S pipes and specials with neat cement or cement mortar and spun yarn including caulking the joints, curing. (including cost of jointing materials)- 1 No - 80 mm 19 100 mm DI D/F Gate valve forScour in 200 mm DI main with fixing of DI Specials as per IS 9523/2000 including loading, transportation and Stacking Charges as per the following sizes as per the drawing, details of valves and specials as below 100 x 100 x 80 mm D.I. D/S B/F Tee - 1 No 80 mm x 2.50 m D.I. D/F- 1 No, 80 mm x 1.0 m D.I. D/F Pipe - 2 Nos, 80 mm DI D/F Gate Valve - 1 No., 80 mm D.I. D/f DFoot bend - 1 No 80 mm DI D/F 90˚ Bend - 2 NoJointing the C.I/ D.I Double flanged pipes and specials with rubber insertion to with IS-638(1979) and M.S. bolts and nuts of IS 1364-1 (2002), including cost of jointing materials such as bolt and nuts Rubber insertion and labour charges etc., complete - 8 Nos - 80 mmJointing the C.I/ D.I-S/S pipes and specials with neat cement or cement mortar and spun yarn including caulking the joints, curing. (including cost of jointing materials)- 2 Nos - 100 mm 80 mm DI Flanged / SPKT TP - 1 No Jointing the C.I/ D.I-S/S pipes and specials with neat cement or cement mortar and spun yarn including caulking the joints, curing. (including cost of jointing materials)- 1 No - 80 mm 20 150 mm DI D/F Gate valve for Scour in 250 mm DI main with fixing of DI Specials as per IS 9523/2000 including loading, transportation and Stacking Charges as per the following sizes as per the drawing, details of valves and specials as below250x 250 x150 mm D.I D/S B/F Tee - 1 No 150 mm x 2.50 m DI D/F Pipe.- 1 No 150 mm x 1.00 m DI D/F Pipe - 2 Nos 150 mm DI D/F Gate Valve - 1 No 150 mm DI D/F DFoot bend - 1 No 150 mm x 1.50 m DI D/F Pipe - 1 No 150 mm DI D/F 90˚ Bend - 2 No (1 No. - 21 kg) C.I Surface box - 1 No Jointing the C.I/ D.I Double flanged pipes and specials with rubber insertion to with IS-638(1979) and M.S. bolts and nuts of IS 1364-1 (2002), including cost of jointing materials such as bolt and nuts Rubber insertion and labour charges etc., complete - 8 Nos - 150 mm Jointing the C.I/ D.I-S/S pipes and specials with neat cement or cement mortar and spun yarn including caulking the joints, curing. (including cost of jointing materials)- 2 Nos-150mm dia 21 200 mm DI D/F Gate Valve for Scour in 300 mm DI main with fixing of DI Specials as per IS 9523/2000 including loading, transportation and Stacking Charges as per the following sizes as per the drawing, details of valves and specials as below300x 300 x200 mm D.I. D/S B/F Tee - 1 No. 200 mm x 2.5 m D.I. D/F Pipe.- 1 No. 200 mm x 1.00 m D.I. D/F Pipe - 2 Nos, 200 mm DI D/F GateValve - 1 No, 200 mm D.I. D/F DFoot bend - 1 No, 200 mm D.I DI D/F 90˚ Bend - 2 No, C.I Surface box - 1 No,Jointing the C.I/ D.I Double flanged pipes and specials with rubber insertion to with IS-638(1979) and M.S. bolts and nuts of IS 1364-1 (2002), including cost of jointing materials such as bolt and nuts Rubber insertion and labour charges etc., complete - 7 Nos - 200 mmJointing the C.I/ D.I-S/S pipes and specials with neat cement or cement mortar and spun yarn including caulking the joints, curing. (including cost of jointing materials)- 1 No -200mm, Jointing the C.I/ D.I-S/S pipes and specials with neat cement or cement mortar and spun yarn including caulking the joints, curing. (including cost of jointing materials)- 2 Nos. 22 300mm For Pumping Main - Air Valve with Specials Manufacture, Supply and Delivery of Tamper proof DI single chamber double orifice, triple function (ventilating, admitting and venting during operation) air release valves with pressure range from PN 1.0 to 2.5 with body and cover made of Ductile Iron of Grade GGG 40 or equivalent grade conforming to IS 1865 with Food Grade Epoxy Powder coating(EP-P) inside and for outside of colour blue RAL 5005. All internal parts such as float, shell etc., cover bolts, made of Austenitic alloy steel of SS AISI 304/316. The float shall be made of Polytetrafluroethylene/ Austenitic alloy steel of AISI 304/316. Gaskets and seals of EPDM / Neoprene rubber for TWAD Board works anywhere in Tamil Nadu includingunloading, transportation and stacking charges.Supply, delivery of Ductile Iron Specials as Per IS 9523/2000including unloading, transportation and stacking charges for fixing of valves with specials including labour charges for lowering, laying,jointing etc complete as directed by Engineer in Charge 23 50 mm DI Single chamber Air release valve in 100 mm DI main with fixing of DI Specials as per IS 9523/2000 and GI Specials as per IS 1239/ Part II including loading, transportation and Stacking Charges as per the following sizes as per the drawing, details of valves and specials as below 100 x 100 x 80 mm DI A / F Tee - 1 No 100 mm DI Flanged Socket T.P. - 1 No 100 mm DI Flanged Spigot T.P. - 1 No 80 x 50 mm G.I. Reducer heavy - 1 No 80 mm G.I. Flange - 1 Set 50 mm G.I.Pipe - 0.15 m50 mm G.I. Flange - 1 set 50 mm DI Single chamber Air release valve - 1 No Jointing the C.I/ D.I Double flanged pipes and specials with rubber insertion to with IS-638(1979) and M.S. bolts and nuts of IS 1364-1 (2002), including cost of jointing materials such as bolt and nuts Rubber insertion and labour charges etc., complete - 2 Nos - 100 mm Jointing the C.I/ D.I Double flanged pipes and specials with rubber insertion to with IS-638(1979) and M.S. bolts and nuts of IS 1364-1 (2002), including cost of jointing materials such as bolt and nuts Rubber insertion and labour charges etc., complete - 1 No - 80 mm Jointing the C.I/ D.I Double flanged pipes and specials with rubber insertion to with IS-638(1979) and M.S. bolts and nuts of IS 1364-1 (2002), including cost of jointing materials such as bolt and nuts Rubber insertion and labour charges etc., complete - 1 No - 50 mm Jointing the C.I/ D.I-S/S pipes and specials with neat cement or cement mortar and spun yarn including caulking the joints, curing. (including cost of jointing materials)- 1 No -100mm dia 80 mm G.I.Pipe - 0.15 m 24 50 mm DI Single chamber Air release valve in 200 mm DImain with fixing of DI Specials as per IS 9523/2000and GI Specials as per IS 1239/ Part II including loading, transportation and Stacking Charges as per the following sizes as per the drawing, details of valves and specials as below 200 x 200 x 80 mm DI A / F Tee - 1 No 200 mm DI Flanged Socket T.P. - 2nos (1 No.- 20 kg) 80 x 50 mm G.I. Reducer Heavy - 1 No 80 mm G.I. Flange - 1 Set 50 mm G.I.Pipe - 0.15 m50 mm G.I. Flange - 1 set C.I Surface box - 1 No 50 mm DI Single chamber Air release valve - 1 No Jointing the C.I/ D.I Double flanged pipes and specials with rubber insertion to with IS-638(1979) and M.S. bolts and nuts of IS 1364-1 (2002), including cost of jointing materials such as bolt and nuts Rubber insertion and labour charges etc., complete - 2 Nos - 200 mm Jointing the C.I/ D.I Double flanged pipes and specials with rubber insertion to with IS-638(1979) and M.S. bolts and nuts of IS 1364-1 (2002), including cost of jointing materials such as bolt and nuts Rubber insertion and labour charges etc., complete - 1 No - 80 mm Jointing the C.I/ D.I Double flanged pipes and specials with rubber insertion to with IS-638(1979) and M.S. bolts and nuts of IS 1364-1 (2002), including cost of jointing materials such as bolt and nuts Rubber insertion and labour charges etc., complete - 1 No - 50 mm Jointing the C.I/ D.I-S/S pipes and specials with neat cement or cement mortar and spun yarn including caulking the joints, curing. (including cost of jointing materials)- 2 Nos. -200mm 80 mm DI Single chamber 25 Air release valve in 250 mm DI main with fixing of DI Specials as per IS 9523/2000 including loading, transportation and Stacking Charges as per the following sizes as per the drawing, details of valves and specials as below250 x 250 x 80 mm DI A / F Tee - 1 No. 250 mm DI Flanged Socket T.P. - 2nos (1 No.-27 kg), 80mm x 1.00 m DI D/F Pipe - 1 No, C.I Surface box - 1 No80 mm DI Single chamber Air release valve - 1 No, Jointing the C.I/ D.I Double flanged pipes and specials with rubber insertion to with IS-638(1979) and M.S. bolts and nuts of IS 1364-1 (2002), including cost of jointing materials such as bolt and nuts Rubber insertion and labour charges etc., complete - 2 Nos - 250 mm Jointing the C.I/ D.I Double flanged pipes and specials with rubber insertion to with IS-638(1979) and M.S. bolts and nuts of IS 1364-1 (2002), including cost of jointing materials such as bolt and nuts Rubber insertion and labour charges etc., complete - 2 No - 80 mm Jointing the C.I/ D.I-S/S pipes and specials with neat cement or cement mortar and spun yarn including caulking the joints, curing. (including cost of jointing materials)- 2 Nos. -250mm 26 80 mm DI Single chamber Air release valve in 300 mm DImain with fixing of DI Specials as per IS 9523/2000 including loading, transportation and Stacking Charges as per the following sizes as per the drawing, details of valves and specials as below 300 x 300 x 80 mm DI A / F Tee - 1 No 300 mm DI Flanged Socket T.P. - 2nos (1 No.-37 kg) 80mm x 1.00 m DI D/F Pipe - 1 No C.I Surface box - 1 No 80 mm DI Single chamber Air release valve - 1 No Jointing the C.I/ D.I Double flanged pipes and specials with rubber insertion to with IS-638(1979) and M.S. bolts and nuts of IS 1364-1 (2002), including cost of jointing materials such as bolt and nuts Rubber insertion and labour charges etc., complete - 2 Nos - 300 mm Jointing the C.I/ D.I Double flanged pipes and specials with rubber insertion to with IS-638(1979) and M.S. bolts and nuts of IS 1364-1 (2002), including cost of jointing materials such as bolt and nuts Rubber insertion and labour charges etc., complete - 2 No - 80 mm Jointing the C.I/ D.I-S/S pipes and specials with neat cement or cement mortar and spun yarn including caulking the joints, curing. (including cost of jointing materials)- 2 Nos. -300mm 27 80 mm DI Single chamber Air release valve in 350 mm DImain with fixing of DI Specials as per IS 9523/2000 including loading, transportation and Stacking Charges as per the following sizes as per the drawing, details of valves and specials as below 350 x 350 x100 mm D.I. A / F Tee - 1 No, 350 mm DI Flanged Socket T.P., 350 mm DI Flanged Spigot T.P. 100x80 D.I. D/F Taper, Surface box - 1 No, 80 mm DI Single chamber Air release valve, Jointing the C.I/ D.I Double flanged pipes and specials with rubber insertion to with IS-638(1979) and M.S. bolts and nuts of IS 1364-1 (2002), including cost of jointing materials such as bolt and nuts Rubber insertion and labour charges etc., complete - 2 Nos - 350 mm, Jointing the C.I/ D.I Double flanged pipes and specials with rubber insertion to with IS-638(1979) and M.S. bolts and nuts of IS 1364-1 (2002), including cost of jointing materials such as bolt and nuts Rubber insertion and labour charges etc., complete - 1 Nos - 100 mm, Jointing the C.I/ D.I Double flanged pipes and specials with rubber insertion to with IS-638(1979) and M.S. bolts and nuts of IS 1364-1 (2002), including cost of jointing materials such as bolt and nuts Rubber insertion and labour charges etc., complete - 1 Nos - 80 mm, Jointing the C.I/ D.I-S/S pipes and specials with neat cement or cement mortar and spun yarn including caulking the joints, curing. (including cost of jointing materials)- 2 Nos. -350mm 28 Earth work excavation and depositing on bank with an initial lead of 10m and initial lift of 2m in the following classification including other incidental charges such as barricading etc excluding refilling in hard stiff clay,stiff black cotton,hard redearth, shales, murram, gravel, stoney earth and earth mixed with small size boulder sand hard gravelly soil complete as directed by the Engineer in Charge. 250mm DI S/S K7 Class Pipe 29 300mm DI S/S K7 Class Pipe 30 350mm DI S/S K7 Class Pipe 31 110mm HDPE PN10 Class Pipe 32 200mm HDPE PN10 Class Pipe 33 Refilling with excavated soil (other than sand) complying with standard specification in layers of 15cm watered well rammed and consolidated after the pipes and specials are laid,jointed and tested etc. and removing and depositing the surplus earth complete as directed by the Engineer-in-charge. 250mm DI S/S K7 Class Pipe 34 300mm DI S/S K7 Class Pipe 35 350mm DI S/S K7 Class Pipe 36 110mm HDPE PN10 Class Pipe 37 200mm HDPE PN10 Class Pipe 38 Lowering of D.I Pipes and specials in the trenches and laying to proper grade and alignment complete as per standard specifications and as directed by the Engineer in Charge.250mm DI S/S K7 Class Pipe 39 300mm DI S/S K7 Class Pipe 40 350mm DI S/S K7 Class Pipe 41 Lowering HDPE pipes and specials to trench and laying to proper grade and alignment complete as per standard specifications and as directed by the Engineer in Charge.110mm HDPE PN10 Class Pipe 42 200mm HDPE PN10 Class Pipe 43 Lowering PVC/ DWSC rigid pipes and specials to trench and laying to proper grade and alignment, jointing with PVC couplers with cement paste complete as per standard specifications and as directed by the Engineer in Charge.50 MM UPVC 6 KSC pipe (Power Cable Cover Pipe) 44 Jointing the DI S/S pipes and specials with rubber gaskets (tyton joint) including cost of lubricants, cost of jointing materials and testing to the required pressure with water etc., complete as per standard specifications and as directed by the Engineer in Charge.250mm DI S/S K7 Class Pipe 45 300mm DI S/S K7 Class Pipe 46 350mm DI S/S K7 Class Pipe 47 Jointing HDPE Pipes and Specials by butt fusion welding / electro fusion welding joints using fusion equipment as per ISO 21307-2011 and as per IS 7634 (part-2) : 2012 including cost of hire charges for butt fusion equipment power supply arrangements etc., complete as per directed by Engineer in Charge.110mm HDPE PN10 Class Pipe 48 200mm HDPE PN10 Class Pipe 49 Testing of M.S. / C.I. / D.I / P.V.C. / H.D.P.E / pipes with hydraulic testing equipment by filling with waterand testing to recommended pressure in convenient stretches and attending the bursts if any occured during the test, excluding the cost of pipes but including other incidential and operational charges etc., complete for the following diametres of pipes.250mm DI S/S K7 Class Pipe 50 300mm DI S/S K7 Class Pipe 51 350mm DI S/S K7 Class Pipe 52 110mm HDPE PN10 Class Pipe 53 200mm HDPE PN10 Class Pipe 54 Valve Chamber :Construction of masonry valve chamber: Earth work excavation for foundation in Hard stiff clay, stiff black cotton, hard red earth, shales murram, gravel,stoney earth and earth mixed with small size boulders SS.20B and Sand, silt or other loose soil, wet sand,or silt not under water, light black cotton soil, sandy loam ordinary soil and to full depth as may be directed except in hardrockrequiring blasting inclusive of shoring shuttering and baling out water and cleaning and levelling the site etc.,complete 10 cumPlain Cement Concrete 1:4:8using 40mm size ISS HBG metal including cost and conveyance of all materials to site and including for the mixing, laying and labour chargesetc., complete as per standard specification Brick work in CM 1:5(one cement & five sand) using ground moulded country bricks of size 8.75 inch X 4.25 inch X 2 3/4 inch standard specification including finishing, curing, etc., complete complying with standard specification - 100cftPlastering with cement mortar (1:3) 12 mm thick in all floors including cost and conveyance of all materials to site and labour charges etc, complete complying with standard specifications (S.I.309)RCC (M20) Precast Slab of 0.15m thickness using 20mm thick hard broken stone jelly and river sand excluding the cost of reinforcement grills and fabrication charges but including moulding, curing, finishing charges and fixing in position neatly complying with standard specification and as directed by the Departmental Engineer etc. complete-Supply and Fixing of Cut Stone Slab all faces dressed including cost and conveyance of all materials to site and including for the mixing, laying and labour chargesetc., complete as per standard specificationCI surface box at a of size 100x125x150 mm conforming to IS 3950 having hinged and weighting not less than 33 kg.The surface box shall be fixed on top of the RCC Refilling the trenches with suitable excavated earth available in layers of 150 mm thick, watering, ramming & consolidation complete as directed by the Engineer in chargecover slab during the casting of slab for key rod operation. The surface box shall be painted with 3 coats of black bitumastic paintConveyance of excess earth to a distance not exceeding 5km as directed by the Corporation Engineer including cost of loading, transportation and unloading charges etc complete (Total Earthwork Quantity - Refilling Quantity)Valve Chamber Size 2.00 m x 1.80 m x 1.30 m 55 Valve Chamber Size 1.20 m x 1.00 m x 1.20 m 56 Valve Chamber Size 1.6 m x 1.1 m x 1.4 m 57 Valve Chamber Size 1.8 m x 1.2 m x 1.6 m 58 Providing anchorage arrangements by drilling borewell using hand bore set to a dia of 4 inserting 110 MM PVC pipe, scooping of sand from the pipe and laying of concrete in PCC 1: 2: 4 including supply delivery and fixing of clamp sets to hold both water carrying and cable encasing pipe and earthwork excavation for a depth of 1.0 M before starting drilling of bore wells as per the details Earthwork excavation Above water level in light or sandy soil for infiltration gallery, syphon or connecting pipe line and connected works including shoring and strutting and charges for special tools and plants for bailing/ pumping etc., such as air compressor and helmet. Drilling of borewells of size 4 to 5 dia in sedimentary formation using hand boresets including insertion of casing pipes etc Supply of the following UPVC Pipe 6 KSc Pipe as per IS specifications 4985/2000 110mm UPVC Pipe For inserting into the drilling bore PCC 1: 2: 4 (one cement, two sand and four aggregates) using 20 MM ISS Guage HBG Stone jelly including cost of all materials at site and labour charges for mixing, laying, compacting, finishing, curing etc, complete and as directed by Department officersSupply and fabrication charges for making clampset sitable for Connecting main including cost of bending drilling holes suitable for bolts, painting one coat of red oxide etc complete and as directed by TWAD Board officers Clampset For 200 mm HDPE PN10 Pipe. Clampset For 50 mm UPVC Pipe Centre Section of 75 mm*100 mm*10 mm- 2No.T Section (1000mm*210mm*10mm-2 No.) Top Side Plates of 75 mm*210 mm*10 mm - 2No. Supply of Bolts and nuts ofsize 16 mm dia x 65 to 90 mm length fully threaded bolts and nuts with 2 Nos. 59 Disposal of surplus earth including loading & unloading, conveyance within a distance of 5 Km and spreading as directed by the Engineer in Charge. For Pipe Quantity andRoad Restoration 60 Labour charges for cutting open roads in BT / WBM for laying of water supply pipe line measurementas directed by the Engineer in Charge. 61 Dismantling concrete roads for layingpipe line excluding cost of earth work in linear measurement as directed by the Engineer in Charge. 62 P.C.C 1:4:8 (one cement, four sand and Eight coarse aggregate) using Ordinary Portland cement and 40 mm H.B.G stone including mixing concrete, laying, curing and compacting of concrete etc., complete and as directed by the engineer in charge.Below GL upto 1.5 m Depth 63 Below GL from 1.50 m upto 4.5 m Depth 64 Flooring with Plain Cement Concrete 1:4:8(one cement, Four fine aggregates and Eight coarse aggregates) using 40mm size ISS HBG metal including cost and conveyance of all materials to site and including for the mixing, laying and labour chargesetc., and finished with cement mortar (1:3) 12 mm thick in all floors including cost and conveyance of all materials to site and labour charges etc, complete complying with standard specifications (S.I.309) 65 P.C.C 1:2:4 (one cement, two sand and four coarse aggregate) using Ordinary Portland cement and 20 mm H.B.G stone including mixing concrete, laying, curing and compacting of concrete etc., complete and as directed by theengineer in charge. Below GL upto 1.5 m Depth 66 BARRICADING FOR PIPELINE WORKS FOR THE WSSWORK: Barricading work (Where, there is less traffic areas and broader roads etc.) for laying of pipe line using casurina poles at 1.50m center to center (8cm to 10cm dia and 1.80m height) vertical with horizontal poles in three rows including painting the vertical poles in the road facing sides with ready mix paint, tying the vertical and horizontal poles with coir rope including fixing charges and fixing 75mm dia reflectors including earth work excavation for fixing vertical posts and finally removing and stacking the materials safely for further use etc., complete and as directed by the engineer in charge. Earth work excavation for foundation in Hard stiff clay, stiff black cotton, hard red earth, shales murram, gravel,stoney earth and earth mixed with small size boulders SS.20B and Sand,silt or other loose soil,wet sand,or silt not under water, light black cotton soil, sandy loam ordinary soil and to full depthwith intiallead and lifts and cleaning and levelling the site and refilling etc.,completeFirst Depth of 2 M 67 Earth work excavation for foundation in Soft disintegrated rock, laterite, soft rock or kankar,not requiring blasting complete and as directed by Departmental OfficersFirst Depth of 2 M 68 Depth of 0M to 2 M 69 Depth of 2 M to 3 M 70 Depth of 3 M to 4 M 71 Earth work excavation for foundation in Medium Rock and Dense Medium Rock not requiring blasting complete and as directed by Departmental OfficersSecond Depth of 2 M to 3 M 72 Providing and laying in position Standardised Concrete Mix M-20 Grade in accordance with IS 456 - 2000 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement content of 325Kg/ cum and maximum water cement ratio of 0.55 including admixture (Plasticiser / super plasticiser) in recommended proportions as per IS 9103 to accelerate, related setting of concrete, improve workability without impairing strength and durability with about (5.0cum), 7730Kg of 20mm machine crushed stone jelly and with about (3.3 cum), 5156kg of 10 - 12mm machine crushed stone jelly and with about (4.79cum) 7670 kg of sand, but excluding cost of reinforcement grill and fabricating charges centering and shuttering but including laying, vibrating with mechanical vibrators, finishing, curing, etc and providing fixtures like fan clamps in the RCC floor / roof slabs wherever necessary without claiming extra cost etc., complete complying with standard specification and as directed by the Engineer incharges - The Coarse and Fine aggregates to be used should comply with the requiremnents of IS staandards. (No separate payment will be made by the Department for the excess usage of materials) Below GL upto 1.50 m Height 73 Above GL Upto 4.5 m Height 74 Providing and laying in position Standardised Concrete Mix M-30 Grade in accordance with IS 456 - 2000 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement content of 340Kg/ cum and maximum water cement ratio of 0.55 including admixture (Plasticiser / super plasticiser) in recommended proportions as per IS 9103 to accelerate, related setting of concrete, improve workability without impairing strength and durability with about (5.0cum), 7730Kg of 20mm machine crushed stone jelly and with about (3.3 cum), 5156kg of 10 - 12mm machine crushed stone jelly and with about (4.79cum) 7670 kg of Msand, but excluding cost of reinforcement grill and fabricating charges centering and shuttering but including laying, vibrating with mechanical vibrators, finishing, curing, etc and providing fixtures like fan clamps in the RCC floor / roof slabs wherever necessary without claiming extra cost etc., complete complying with standard specification and as directed by the Engineer incharges - The Coarse and Fine aggregates to be used should comply with the requiremnents of IS staandards.Below GL upto 1.50 m Height 75 Below GL 1.50 - 4.50 M DEPTH 76 Above GL 0 -4.50 M 77 From 4.50 m to 7.32 m ht. From G.L. 78 From 7.32 m to 10.98 m ht. From G.L. 79 From 10.98 m to 14.64 m ht. From G.L. 80 From 14.64 m to 18.30m 81 From 18.3 m to 21.96m 82 Sinking of infiltration well of 4.50m internal dia and 5.40m external dia below water level including all incidental charges in light or sandy soil directed by the Engineers @ well curbincluding all labour charges etc, complete and as directed by Departmental Officers. 1st Depth of 2m 83 2nd Depth of 2m 84 3rd Depth of 2m 85 4th Depth of 2m 86 Porous concrete in CC 1:4 (One cement and four hard broken granite jelly of a size 20mm) for steining of infiltration well excluding cost of centering but including curing etc., complete and as directed by the Engineers @ well curbincluding all labour charges etc, complete and as directed by Departmental Officers. 87 Providing for cutting edge using 12G MS sheets including the cost of fabricating welding and placing in position in the curb including supply of the MS sheet. 88 Plugging the bottom of the well with coarse sand of approved sizes and grade as directed by the Board officers. Well curb triangular portion including all cost and conveyance of materials to site and all Labour charges etc, complete. (10 mm Stone) 89 Brick work in CM 1:5(One Ordinary Portland Cement (OPC) & Five Sand) using ground moulded Second Class Chamber burnt bricks of size 9 x 4 3/8 x 2 3/4standard specification including finishing, curing, etc., complete complying with standard specification and as directed by Departmental officers.Above GL Upto 4.5 m Height 90 Special ceiling plastering with CM 1:3 mix 10mm thick complying with standard specification and as directed by the Departmental Officers. 91 Plastering with cement mortar (1:5) 12 mm thick in all floors including cost and conveyance of all materials to site and labour charges etc, complete complying with standard specifications and as directed by Departmental officers. 92 Painting two coats for Exterior surface with approved Exterior Plastic Emulsion paint approved quality and colour over a priming coat, including thorough scrapping, clean removal of dirt, etc complete and including necessary plaster of paris, putty, wherever required etc, complete as per standard specification. 93 Painting two coats for Interior surface with approved Interior Plastic Emulsion paint approved quality and colour over a priming coat, including thorough scrapping, clean removal of dirt, etc complete and including necessary plaster of paris, putty, wherever required etc, complete as per standard specification. For Pump Room-Nearby 2.00 LL Proposed Sumps - 2 No. 94 Supplying, fabricating and fixing of MS Grills with Doors and Window gate (5.00 mx 1.80 m) with one Coat of Red Oxide with primer including all costs such as welding, grinding, fabrication charges cost and Conveyance at all materials to site etc.complete as per Standard Specification. 95 Painting two coats with Ready Mixed Enamel Paint in MS Grill gate (5 mx 1.80) two sleevesover the new iron works of approved quality and colour without priming coatincluding the cost all materials etc.,complete, in all Grill Works. 96 Supply, delivery fabrication and placing inposition of MS, RTS rods for reinforcement for binding ring, pilasters, roof slab and well curb including cost of binding wire etc. complete and as directed by Departmental Officers. 97 Providing steel centering using MS plate of size 90 cm x 60 cm - 13G to 10G thick welded with 25 cm x 3 mm MS angles supported with country wood scantling of size 10 cm x 6.5 cm at 50 cm c/c strutting with casuarinas props of 10 cm to 13 cm dia etc. complete and as directed by Departmental officers. Plain Surface - 0-3.30m 98 3.30m - 4.30m 99 6.30m - 7.30m 100 7.30m - 8.30m 101 10.30m - 11.30m 102 11.30m - 12.30m 103 14.30m - 15.30m 104 15.30m - 16.30m 105 Curved Surface - 0-3.30m 106 3.30m to 4.30 m 107 15.30m to 16.30 m 108 Circular Column 0-3.30m 109 3.30m-4.30m 110 4.30m-5.30m 111 5.30m-6.30m 112 6.30m-7.30m 113 7.30m-8.30m 114 8.30m-9.30m 115 9.30m-10.30m 116 10.30m-11.30m 117 11.30m-12.30m 118 12.30m-13.30m 119 13.30m-14.30m 120 14.30m-15.30m 121 Square Column- 0-3.30m 122 3.30m-4.30m 123 4.30m-5.30m 124 5.30m-6.30m 125 6.30m-7.30m 126 7.30m-8.30m 127 8.30m-9.30m 128 9.30m-10.30m 129 10.30m-11.30m 130 11.30m-12.30m 131 12.30m-13.30m 132 13.30m-14.30m 133 14.30m-15.30m 134 15.30m-16.30m 135 Supply and fixing of CI manhole cover of size 0.60 x 0.60 m with locking arrangements including the cost of RI sheet and fixing at the edges etc. complete and as directed by Department. officers. (heavy type) 136 Supply and fixing of PVC mould CI steps to be embeddedwith vertical clearance of 0.30 m c/c and horizontal clearance of 0.38 mc/c in staggered manner etc. complete and as directed by Departmental officers. 137 ProvidingGIventilating arrangementof size 0.10m and as directed by the Departmental officers Supply and delivery of 100mm GI Pipe nipple - 0.5 mSupply and delivery of 100 mm GI Pipe nipple - 0.30 mSupply and delivery of 100mm GI Tee - 1 NoSupply and delivery of 100 mm GI Bend - 2 No 138 Supplying and filling in foundation andbasement with stone dust in layers of not more than 15cm thick well rammed watered and compacted etc., complete complying with standard specification. 139 Refilling the sides of foundation with excavated earth (other than sand) in layersof 15cm thick, wateredwell rammed and consolidated etc.complete complying with standard specification removing and spreading the surplus earth at the placed shownand as directed by the dept officers. 140 Ellis Pattern flooring with 20mm thick in Cement Concrete 1:2:4 Mix using 3 to 10 mm Stone JellyChips and top surfaces rended smooth in Cement – 10m2( no sand to be used ) complete in accordance with the specification and as directed by the Departmental Officers. 141 Supply and Delivery Fabrication of MS doors and windows with outer frame and shutter frame in MS angle of size 40mm x 40mm x 6 mm with MS flat 25mm x 25mm x 6mm and MS sheet of 18 gauge including ventilating arrangements using 20mm square MS rods with locking arrangements including two coats of approved enamel paint over coat of red oxide including cost of angles, plates, sheets, fabrication charges, cost of hold fast and transportation charges etc., complete.Fully panelled double leaf Door - D - 1.00 m x 2.00m 142 Fully panelled double leaf window W1- 0.90 x 1.20m 143 Fully panelled single leaf Ventilator - V -0.45 m x 0.60 m 144 Weathering course with surki concrete by using broken brick jelly 20mm size in pure slaked lime over RCC roof slab, the proportion (being 32:12.5) for required depth of 80mm for giving required slope and thickness to roof as required, well beaten with wooden beaters, including cost of all materials, labour charges, curing etc., complete and as directed by Department Officers. 145 Finishing the top of weathering course with one course of hydraulic machine pressed tiles of size 20cm x 20cm x 2cmof approved quality using CM 1:3 mixed with crude oil 10% by weight of cement using P Sand and pointed with same oiled mortor including cost of all materials, labour charges, curing etc., complete and as directed by Department Officers. 146 Supplying and fixing of cut stones size 0.45x0.45x0.15mfor Overhead Tanks Complete as per standard specifications and as directed by departmental officers 147 Providing and fixing of RCC access ladderin RCC 1:1.5:3 (one cement, one and half sane! and three aggregates) using 20mm HBG stone for OHT including cost of reinforcement, placing grill in position, centering shuttering charges, mixing concrete curing etc., to required height and clear width of 4Scm consisting of two Nos. of ve~ical post of 10cm x lS cm and step slab of 2Smm x 25mm etc., complete and as directed by Deptofficers. RCC Inside Access LadderFor 2.00 LL Proposed Sump - 5.25 m 148 For 2.00 LL Proposed Sump - 2.30 m 149 For 0.60 LL OHT - 2 No - 3.80 m 150 For 1.00 LL OHT - 3.20 m 151 For 2.50 LL OHT - 3.75 m 152 For 3.00 LL OHT - 2 No - 4.25 m 153 For 2.00 LL OHT - 4.25 m 154 Providing RCC ventilator over roof slab and roof domefor Overhead Tanks Complete as per standard specifications and as directed by departmental officers (0.15 m dia) 155 Providing RCC spiral staircase as per approved design for Overhead Tanks Complete as per standard specifications and as directed by departmental officersFor 0.60 LL OHT - 2 No. 156 For 1.00 LL OHT 157 For 2.50 LL OHT 158 For 3.00 LL OHT - 2 No. 159 For 4.00 LL OHT 160 Providing RCC hand rail of 1.2 m height around the top of the roof slab with jolly workfor Overhead Tanks Complete as per standard specifications and as directed by departmental officers RCC POST 161 RCC JOLLY WORK 162 Provision for pipe connection arrangements for inlet outlet, scour and overflow etc., including cost of pipes, specials, valve, labour charge for lifting, aligning, cutting, threading etc., complete as detailed below.0.60 LL OHT - Pipe detailsInlet-∅100mmOutlet -∅125mmScour -∅80mmOverflow-∅100 mm 163 1.00 LL OHT - Pipe detailsInlet-∅125mmOutlet -∅150mmScour -∅80mmOverflow-∅125 mm 164 2.50 LL OHT - Pipe detailsInlet ∅-150mmOutlet ∅-200mmOverflow ∅-150mmScour ∅-100mm 165 3.00 LL OHT - Pipe detailsInlet ∅-200mmOutlet ∅-250mmOverflow ∅-200mmScour ∅-100mm 166 4.00 LL OHT - Pipe detailsInlet ∅-200mmOutlet ∅-250mmOverflow ∅-200mmScour ∅-150mm 167 Labour charges for Painting Emblem in accordance with the size and specifications as approved by the Board on the Service Reservoirs including cost of all consumables, one coat of base paint, scaffolding charges on the Service Reservoirs. 168 Supply, delivery and fixing of enameled water level indicator of approved design and pattern (graduation in metric system) with required all accessories as directed by Departmental Officers. 169 Supply and delivery of Open well Submersible pump set conforming to IS 14220 /2002 and as amended thereafter and BEE 3 Star Rated capable of discharging the following duties due to all causes. The pump shall be with stainless steel shaft and dynamically balanced bronze mixed type impeller, CI FG 200 grade casing and brass screws and rotor shall be of copper rod as per IS 613/1984 with ISI mark. The pump suitable for installation in sump with 1.1KV grade 3 core suitable copper flat submersible cable to a length of 15m with necessary cable joints. The non-return valve located at the top of the pump in the discharge outlet connection is to be designed with minimum friction.The pump should be directly coupled to 2880 RPM, three phase, 50 Hz (±5), 415V+6% & 415V-15% squirrel cage induction motor suitable for DOL upto 5 HP , Fully AutomaticAir break Star Delta up to 20 HP and Auto Transformer starter for above 20 HPstarting and for continuous operation, complete as directed by Departmental Officers.605 LPM x 30 M - 5 HP Head for 6 Proposed Infiltration Wells 170 Supply and delivery of Horizontal split casing centrifugal pump conforming to IS 1520 and as amended thereafter with CI casing and split glands, stainless steel shaft, hydraulically and dynamically balanced bronze impellers capable of discharging required quantity of water against a total head noted below due to all causes and with the accessories such as G.M air release cock, Grease cup, G.I priming funnel, M.S lifting hook, drip water G.I pipe connections, leading to the outside of pump house rubber water deflector, double flap foot valve, G.M strainer including unique tyre type coupling, common M.S fabricated base to mount pump and motor and other standard fittings etc complete. Pump shall be capable of discharging the specified quantity at the head noted at the minimum NPSH at site conditions. The shut off head shall be atleast 25% over and above the head at duty point. The pump shall be suitable for operation in AC three phase, 415 V, 50 Hz, 1500 RPM.complete as directed by Departmental Officers. 2830 LPM x 40 M Head - 33 HP @ Intermediate Sump 171 2830 LPM x 35 M Head - 29 HP @ Vallipuram Headworks 172 Supply and delivery of AC three Phase 4 pole Horizontal squirrel cage Induction motor confiriming to IS 325/1996 and as amended thereafter with Class F insulation to suit the speed of pump and suitable for operation with continous S1 rated, 415 V +/- 10 %, 50 HZ +/- 5%, TEFC (upto 20 HP), SPDP (above 20 HP). The motor offered should be of energy efficient motors. 2830 LPM x 40 M Head - 33 HP @ Intermediate Sump 173 2830 LPM x 35 M Head - 29 HP @ Vallipuram Headworks 174 Supply and delivery of Fully Automatic Auto Transformer Starter suitable for the motor offered. Floor mounting type air/ oil cooled Auto Transformer Starter with tapings at 50%, 65%, 80%, housed in robust steel chamber with arc and main contacts confirming to IS 8544 Part IV and as amended therafter for operation in AC three Phase 50 Hz (+/- 5%), 415V (+/- 10%) with the following components, under voltage release with no volt coil, over load relay with dash pot arrangements, single phasing preventor, LED ON/ OFF switches, Mounted Ammeter, Earth leakage relay, contactor assembly suitable for next standard KW rating, in coming and out going cable entry provisions, transformer tank including first filling of oil etc. 2830 LPM x 40 M Head - 33 HP @ Intermediate Sump 175 2830 LPM x 35 M Head - 29 HP @ Vallipuram Headworks 176 Supply and delivery of direct online starter confirming to IS13947, IEC60947-1 and as amended thereafter with suitable KW rating for operation in AC/Three Phase/50HZ(± 5%) and 415 V(±10%) including Ammeter, Voltmeter, Thermal Overload relay, 16 Amps 2 pole Magnetic Contactor with under Voltage protection, Indication lamp, starting capacitor, running capacitor and On/Off Push button switches, 5 way connector, wiring with 1 sq. mm/1.5 sq. mm copper PVC insulated cable, powder coated vermin proof box including the capacitor (the cost of capacitor is to be taken separately). 605 LPM x 30 M - 5 HP Head for 6 Proposed Infiltration Wells 177 Supply and delivery of Power capacitor for power factor improvement with oil filled with discharge resistance 3 phase 415 / 440V 50 HZ conforming to ISS with ISI marking complete as directed by Departmental Officers. 178 Providing TWIN CI EARTHING as per IS 3043/1987 and Latest amendments, complete, as directed by Departmental Officers.For above 25-60 HP installation 179 Supply and delivery of L.T. Cables 1.1 KV Grade Armoured Aluminium conductor cross linked Poly Ethylene insulated PVC sheathed cables confirming toIS 7098 (Part I)/1988with ISI marking, complete and as directed by Departmental OfficersFor Proposed Sump - 2.00 LL at Vallipuram Headworks and Intermediate Location - 2 No.3 Core 4 Sq.mm LT Cable 180 3 Core 16 Sq.mm LT Cable 181 3 Core 70 Sq.mm LT Cable 182 Supply and delivery of PVC INSULATED AND SHEATHED 3 CORE FLAT TYPE COPPER CABLE CONFORMING TO IS 694/1990 AND AS AMENDED THEREAFTER complete and as directed by Departmental Officers.3 Core 10 Sq.mm PVC Insulated and Sheathed Cable 183 Laying of Electrical Cables in trenches inside the pump room or in air, complete. and as directed by Departmental Officers. 184 JOINTING OF XLPE INSULATED AND SHEATHED 3 CORE FLAT TYPE COPPER CABLE CONFORMING TO IS 694/1990 AND AS AMENDED THEREAFTER and as directed by Departmental Officers.3 Core 10 Sq.mm PVC Insulated and Sheathed Cable 185 Jointing of L.T.Cables 1.1 KV Grade Armoured Aluminium conductor cable confirming to IS 1554/ Part 1 with ISI marking, complete. and as directed by Departmental Officers.3 Core 4 Sq.mm LT Cable 186 3 Core 16 Sq.mm LT Cable 187 3 Core 70 Sq.mm LT Cable 188 Labour charges for the erection of submersible pump set in bore well / openwell including fixing and jointing submersible cable with proper clamps upto the starter to required depth and also fixing of riser pipes to the required depth valves erection clamps, pressure gauges upto the exterior wall of pump room and erection of panel board consisting of TPICN switches starter, Voltmeter, Ammeter, three pilot (indicating) lamps capacitor single phasing preventor, water level guard and laying and jointing the cables and twin earthing as per IE rules etc., complete and testing the pumpset and trail run for 10 days complete and as directed by DepaUpto 5 HPrtmental Officers. 189 Labour Charges for erection of Horizontal shaft, centrifugal pumpset (Coupled/Monoblock) in bore well/Open well including fixing of suction pipe and foot valve upto a maximum depth of 7 metres and delivery pipes to the required length with valves, pressure gauges upto the exterior wall of pump room and erection of panel board consisting of TPIC switches starter, Voltmeter, Ammeter, Capacitor single phasing preventor and laying and jointing the cables and twin earthing as per IE rules including providing bed blocks etc., complete and operating the pumps and trial run for 10 days including signing of completion of reports complete and as directed by Departmental Officers.Above 30 HP to 40 HP 190 Above 20 HP to 30 HP 191 Supply and Delivery of Horizontal Three Phase Distribution Board with MCBS 4 way / 6 way / 8 way / 12 wayTPMCB sheet steel distribution boards Flush type / Surface type fitted with Bus bars and Neutral links with single/ three phase MCB outgoings and separate 4 way provision for accommodating one No. 4 pole incoming MCB / Isolator and another separate 4 way provision for accommodating one No. 4 pole ELCB / RCD with label holder and provisions for taking up cable for size not less than 35 sq.mm. completewith Metal door cover with IP 42 protection as directed by TWAD Board Officers - Legrand (MDS)/ HAGER (L&T) -4 ways 3 Phase DB .(TWAD SOR 4.XVIII 1 pg 231)605 LPM x 30 M - 5 HP Head for 6 Proposed Infiltration Wells 192 Supply and delivery of floor mounting type weather, vermin and dust proof powder coated M.V. cubical panel board of 14 SWG M.S. Sheet and MS angle iron frame work with enclosed copper busbar 4 Nos. of required current carrying capacity with all internal wiring as per I.E. Rules,. The design of panel board should facilitate for quick operation of all switches from the front side. The panel board should be completed with all internal wiring including necessary twin copper earthing arrangements and consists of the components for controlling incoming and outgoing supply, complete and as directed by Departmental Officers. 250 Amps MCCB with Thermo Magnetic Release 4 Pole to control the incoming load from EB supply to Panel Board 193 250 AmpsMCCBwith Thermo Magnetic Release 3 Pole to control outgoing supply to the pumpsethead with interlocking 194 MCB 240 V/415 V 50HZ AC SUPPLY Triple Pole 63 A, 10 KA (Higher End ) to control outgoing supply to Vaccuum Pumpset 195 MCB 240 V/415 V 50HZ AC SUPPLY Triple Pole 63 A, 10 KA (Higher End ) to control outgoing supply to capacitor bank 196 MCB 240 V/415 V 50HZ AC SUPPLY Triple Pole 63 A, 10 KA (Higher End ) to control outgoing supply to lighting load 197 Pumproom Wiring Wiring with 1.5sq.mm(22/0.3) PVC INSULATED SINGLE CORE MULTI STRAND FIRE RETARDANT FLEXIBLE COPPER CABLE WITH ISI MARK CONFORMING TO IS 198 Supply and Delivery of BOX TYPE SINGLE FLUORESCENT FITTING WITH COPPER CHOKE AND CONDENSOR COMPLETE WITH ISI MARK- 4 Ft. 40 Watts Box type with Ballast (Philips/Crompton / Wipro / Equivalent) complete and as directed by Departmental Officers. 199 Supply and Delivery of FLUORESCENT TUBULAR LAMPS WITH ISI MARK - Cool Day light 4 Ft. 40 Watts complete and as directed by Departmental Officers. 200 Supply and Delivery of Plug and Sockets- 5 Amps /15 amps.3 pin flush type wall socket only, complete and as directed by Departmental Officers. 201 Supply and Delivery of Plug and Sockets- 15 Amps 3 pin Top, complete and as directed by Departmental Officers. 202 AC Chargeable Emergency Lamp 2 x 11W PL Lamp with all connected accessories 203 Supply and Delivery of Led outdoor fittings -48 Watts LED Focus light with LED fittings, complete and as directed by TWAD Board Officers. 204 Supplyanddeliveryoffollowingsetoftoolsmountedon ateakwoodtoolBoard to befixedonthewall of the pumproom, complete and as directed by Departmental Officers. DE Spanner set 6 to 32 Jhalani Make or equivalent 205 Rings spanner set 6 to 32 Jhalani Make or equivalent 206 200mm Screw Driver 825 Taparia Make or equivalent 207 300mm Screw Driver 829 Taparia Make or equivalent 208 800gm Ball Pane Hammer with Handle Taparia Make 209 Pipe Wrench 14” Jhalani Make or equivalent 210 Pipe Wrench 24” Jhalani Make or equivalent 211 6” Chain wrench best India make or equivalent 212 Supplyanddeliveryoffollowingsafety appliances, complete and as directed by Departmental Officers.Electrical gloves tested to 11 KV /22 KVwith wooden box dusted with french chalk powder 213 Wooden First Aid Box 214 Laminated shock treatment chart 215 Fire Buckets-4 Nos made out of 40 x 40 x 6 mm MS Angle 216 Fire Extinguisher Co2, 4.5 kg. confirming to TAC Norms 217 Supply and delivery of Change over switches complete and as diected by Departmental Officers. 63 Amps 3 phase 500 Volt 4 poleto the pumpset 218 400 Amps 3 phase 500 Volt 4 poleto the pumpset 219 Supply , delivery and fixing of GI/CI D/F pipes and specials for providing pipe connection for the pumpset, complete and as directed by Departmental Officers.100 mm DI D/F Pipe from Suction Side to 100 mm Diameter Gate Valve, Reflux Valve in Delivery Side to 200 mm Outlet with necessary specials and joints For Proposed Infiltration Wells - 6 No.SUCTION SIDE SUCTION SIDE 100 mm X 2 M DI. D/F PIPE- 6 Nos 100 mm DI.D/F 90 DEG BEND- 2 Nos 100 mm X 0.3 M DI. D/F PIPE- 2 Nos DELIVERY SIDE 100 mm DI D/F Gate Valve - 2 Nos 100 mm DI D/F Non - Return Valve - 2 Nos 100 mm X 0.3 M DI. D/F PIPE-2 No.) 100 mm DI.D/F 90 DEG BEND- 1 No 100 mm X 0.3 M DI. D/F PIPE- 1 No.) 100 mm x 100 mm x 100 mm DI.A/F TEE- 1 Nos 100 mm X 1 M DI. D/F PIPE- 1 No. 100 mm DI.D/F 90 DEG BEND- 1 Nos 100 mm X 2.0 M DI. D/F PIPE- 1 Nos 100 mm DI.D/F 90 DEG DUCKFOOT BEND- 2 No 100 mm to 200 mm DI.D/F Eccentric Enlarger - 1 No Jointing the C.I/ D.I Double flanged pipes and specials with rubber insertion to with IS- 638(1979) and M.S. bolts and nuts of IS 1364-1 (2002), including cost of jointing materials such as bolt and nuts Rubber insertion and labour charges etc., complete. - 100 mm - 24 No. 220 200 mm Inlet, 80mm Overflow, 250 mm DI D/F Pipe from Suction Side to 250 mm Diameter Gate Valve, Reflux Valve in Delivery Side to 300 mm Outlet with necessary specials and joints For Proposed Sump - 2.00 LL at Vallipuram HeadworksInlet Side 200 mm DI. D/F DUCK FOOT BEND- 6 No. 200 mm x 3 M DI. D/F PIPE-6 No. 200 mm DI.D/F 90 DEG BEND- 6No. 200 mm x 1 M DI. D/F PIPE- 6 No. 200 mm DI.D/F 90 DEG BEND- 6No. 200 mm x 5 M DI. D/F PIPE-6 No. (Slotted) 200 mm DI. Bellmouth- 6No. Jointing the C.I/ D.I Double flanged pipes and specials with rubber insertion to with IS-638(1979) and M.S. bolts and nuts of IS 1364-1(2002), including cost of jointing materials such as bolt and nuts Rubber insertion and labour charges etc., complete. -200 mm - 42 No. Overflow Side 80 mm DI.D/F 90 DEG BEND- 1No. 80 mm x 1 M DI. D/F PIPE- 1 No. Jointing the C.I/ D.I Double flanged pipes and specials with rubber insertion to with IS-638(1979) and M.S. bolts and nuts of IS 1364-1(2002), including cost of jointing materials such as bolt and nuts Rubber insertion and labour charges etc., complete. - 80 mm - 1 No. SUCTION SIDE 300 mm DI.DUCK FOOT BEND- 2 Nos 250 mm x 5 M DI. D/F PIPE- 2 Nos 250 mm DI.D/F 90 DEG BEND- 2 Nos 250 mm x 5 M DI. D/F PIPE- 2 Nos DELIVERY SIDE 250 mm DI D/F Gate Valve - 2 Nos 250 mm DI D/F Non - Return Valve - 2 Nos 250 mm DI.D/F 90 DEG BEND- 1 No 250 mm X 0.3 M DI. D/F PIPE- 1 No.) 250 mm x 250 mm x 250 mm DI.A/F TEE- 1 Nos 250 mm DI D/F Electomagnetic Flow Meter - 1 Nos 250 mm x 1 M DI. D/F PIPE- 1 No. 250 mm to 300 mm DI. D/F Eccentric Enlarger - 1 No. 300 mm DI Flanged Spigot T.P - 1 No. Jointing the C.I/ D.I Double flanged pipes and specials with rubber insertion to with IS-638(1979) and M.S. bolts and nuts of IS 1364-1(2002), including cost of jointing materials such as bolt and nuts Rubber insertion and labour charges etc., complete. -250 mm - 16 No. Jointing the C.I/ D.I Double flanged pipes and specials with rubber insertion to with IS-638(1979) and M.S. bolts and nuts of IS 1364-1(2002), including cost of jointing materials such as bolt and nuts Rubber insertion and labour charges etc., complete. - 300 mm - 1 No. 221 300 mm Inlet, 80mm Overflow, 250 mm DI D/F Pipe from Suction Side to 250 mm Diameter Gate Valve, Reflux Valve in Delivery Side to 350 mm Outlet with necessary specials and jointsFor Proposed Sump - 2.00 LL at Intermediate Location Inlet Side 300 mm DI. D/F DUCK FOOT BEND- 1 No. 300 mm x 3 M DI. D/F PIPE- 1 No. 300 mm DI.D/F 90 DEG BEND- 1No. 300 mm x 1 M DI. D/F PIPE-1 No. 300 mm DI.D/F 90 DEG BEND- 1No. 300 mm x 5 M DI. D/F PIPE- 1 No. (Slotted) 300 mm DI. Bellmouth-1 No. Jointing the C.I/ D.I Double flanged pipes and specials with rubber insertion to with IS-638(1979) and M.S. bolts and nuts of IS 1364-1(2002), including cost of jointing materials such as bolt and nuts Rubber insertion and labour charges etc., complete. -300 mm Overflow Side 80 mm DI.D/F 90 DEG BEND- 1No. 80 mm x 1 M DI. D/F PIPE- 1 No. Jointing the C.I/ D.I Double flanged pipes and specials with rubber insertion to with IS-638(1979) and M.S. bolts and nuts of IS 1364-1(2002), including cost of jointing materials such as bolt and nuts Rubber insertion and labour charges etc., complete. - 80 mm - 1 No. SUCTION SIDE 300 mm DI.DUCK FOOT BEND- 2 Nos 250 mm x 5 M DI. D/F PIPE- 2 Nos 250 mm DI.D/F 90 DEG BEND- 2 Nos 250 mm x 5 M DI. D/F PIPE- 2 Nos DELIVERY SIDE 250 mm DI D/F Gate Valve - 2 Nos 250 mm DI D/F Non - Return Valve - 2 Nos 250 mm DI.D/F 90 DEG BEND- 1 No 250 mm X 0.3 M DI. D/F PIPE- 1 No.) 250 mm x 250 mm x 250 mm DI.A/F TEE- 1 Nos 250 mm DI D/F Electomagnetic Flow Meter - 1 Nos 250 mm x 1 M DI. D/F PIPE- 1 No. 250 mm to 350 mm DI. D/F Eccentric Enlarger - 1 No. 350 mm DI Flanged Spigot T.P - 1 No. Jointing the C.I/ D.I Double flanged pipes and specials with rubber insertion to with IS-638(1979) and M.S. bolts and nuts of IS 1364-1(2002), including cost of jointing materials such as bolt and nuts Rubber insertion and labour charges etc., complete. -250 mm Jointing the C.I/ D.I Double flanged pipes and specials with rubber insertion to with IS-638(1979) and M.S. bolts and nuts of IS 1364-1(2002), including cost of jointing materials such as bolt and nuts Rubber insertion and labour charges etc., complete. - 350 mm 222 2T capacity hand operated over head Travelling (HOT) crane suitable for a span upto 6 Mtrs, and travel length upto 10 Mtrs. with clear lift upto 6 Mtrs. including gear type chain pulley block with GI chain and geared Travelling trolley complete with all accessories including girdercomplete as directed by Departmental Officers. 223 Supply and delivery of 150mm dia Pressure Gauge and Vaccum guage including all accessories as per specification (For Suction and Delivery to be mounted on wall on Teak Wood Board) complete as directed by Departmental Officers. 224 Supply and delivery ofLT/LTCT METERING BOX as per IE rules and TANGEDCO norms-Up to 50HP/37 KW (which includes LT meter panel board, 6 Nos. suitable fuse carriers).
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 2
8.
Educational and Research Institute #10115164 Price Bid
Design, Supply, Installation And Commissioning Of A Cleanroom , A ) Cleanroom Construction 1.0 ) Wall Paneling And Ceiling A ) Progressive Type Double Skin Modular 100 Mm Thick Solid Wall Panel Made Of 0.8 Mm Thick Powder Coated Sheets On Both Sides With Puf As Infill Of Density 40 ± 2 Kg / M3, Gi Profiles For Reinforcement Along The Periphery With Bottom Track, And Necessary Arrangements, All Joints Shall Be Sealed With Cleanroom Compatible Neutral Grade Silicon Sealant. All The Cut-Outs Should Be Covered With Suitable Channels. , B ) Progressive Type Double Skin Modular 100 Mm Thick Wall Panel With Inbuilt Riser For Return Air Made Of 0.8 Mm Thick Powder Coated Sheets On Both Sides With Puf As Infill Of Density 40 ± 2 Kg / M3, Gi Profiles For Reinforcement Along The Periphery With Bottom Track, And Necessary Arrangements, All Joints Shall Be Sealed With Cleanroom Compatible Neutral Grade Silicon Sealant. All The Cut-Outs Should Be Covered With Suitable Channels. , C ) Ceiling Wall Panels I ) Grid Type Ceiling System For Class 100The Cleanroom Ceiling Shall Be Formed From A Heavy Duty Aluminium Walkable Extruded T-Grid Ceiling Systems For All Areas. Ceiling Grid Colour Should Match Wall Panel Colour ( Designer White Shade ) . The Ceiling Grid Shall Be Heavy Duty Walkable Inverted T-Grid Ceiling System Of Approx.. 50 Mm Twidth ( Gasket Type Ceiling ) To Be Provided On 600Mm X 1200Mm Hanging Configuration, The System Shall Include Aluminum ( Approx. 50 Mm Wide ) Extrusions, Aluminum Extruded Cross Connector With Hammer Head Bolts And Nuts, M8 Bolt And Matching Square Hanger And Other Standard Accessories. The Grid Should Be Suspended From The Parent Building Roof With Adequate Size Fasteners Etc. For Ensuring Structural Stability Of The Ceiling. Blank Ceiling Panels:50Mm Thick Heavy Duty Walkable Al. Honeycomb Ceiling Blank Panel Of Dimension 1200 Mm X 600Mm X 45 Mm / 50 Mm Thick, Using 45 / 50Mm Thick Aluminum Honeycomb Core Laminated With 0.8 Mm Thick Aluminum Skin On Both Sides, Static Dissipative Finished Of Designer White Shade All Complete. , Ii ) Progressive Type Ceiling For Class 1000 Progressive Type Double Skin Modular 75 Mm Thick Ceiling Wall Panel Made Of 0.8 Mm Thick Powder Coated Sheets On Both Sides With Puf As Infill Of Density 40 ± 2 Kg / M3, Gi Profiles For Reinforcement Along The Periphery With Bottom Aluminium Track, And Necessary Arrangements, All Joints Shall Be Sealed With Cleanroom Compatible Neutral Grade Silicon Sealant. All The Cut-Outs Should Be Covered With Suitable Channels. , D ) Coving: Coving Radius 50 Mm, Moc: Aluminiumcoving Shall Be Installed At :1 ) Wall To Wall 2 ) Wall To Ceiling 3 ) Wall To Flooring , E ) Coving 3D Inner Corner Pieces , F ) Outer Coving , G ) 2D Outer Coving Corner Pieces , H ) Wall Panel Cutouts : All The Necessary Cutouts Made On Wall Panels And Ceiling Will Be Flashed With Gi / Ms Powder Coated C-Channels , I ) Suspended Ceiling Support And Wall Panel Accessories : All The Suspended Ceiling Panels Will Be Supported With 10 / 8 Mm Threaded Rod And Turnbuckle For Easy Level Adjustment At Suitable Locations. Ancillaries Like C-Channel, L-Angles, Required For The Installation Ofm2 Wall & Ceiling Panels , J ) Window Modules Viewing Panels Shall Be Of Double Glazed 5Mm Thick Clear Toughened Glass, Finished With 20Mm Wide Ceramic Borderdimensions: 900X900 In Mm , K ) Cleanroom Doors: The Cleanroom Wall Systems Shall Include All Doors Complete With All Associated Hardware. The Cleanroomdoors Shall Be Of Gi / Ms Powder Coated Construction Of Approximate Size , Flush Configuration, Swing Type, Double Skin. Door Frame Powder Coat Color Must Match With Clean Room Wall System, With Door Closer, Handles, Lock Sets With Option Of One Or Both Side Access, View Glaze Shall Be Of Double Glazed 6Mm Clear Toughened. I ) Cleanroom Single Door-900X2100 In Mm , Ii ) Cleanroom Singleemergency Door-900X2100 In Mm , Iii ) Cleanroom Double Door -1400X2100 In Mm , L ) Fan Filter Modules And Hoodedhepa Filter Modules I ) Hooded Hepa Filter Modules For Class 1000 Hepa Filter Modules: The Cleanroom Ceiling System Shall Include Hepa Filter Ceiling Modules As Indicated On The Drawing. *The Filters Will Be Used As Terminal Air Distribution Device. The Air Supply Plenum Shall Be Connected Directly To A Connecting Collar On The Filter Top With Individual Damper In The Plenum And Flexible Ducts. * The Filters Shall Have H14 Class Filters As Per En1822 With An Efficiency Of 99.95%*The Design Air Velocity Through Filter Shall Be 0.45M / S With Ipd Of 130±5% Pa Or Better.*The Frame Of The Filter Shall Be Of Extruded Anodized Aluminium Construction.*The Filter Media Shall Be Glass Fibre With Hot Melt Separator. *The Filter Shall Have Expanded Sheet Metal Face Guard. The Face Guard Shall Be Powder Coated In Off-White Colour.* The Filter Shall Be Having Endless Polyurethane D-Profile, Liquid Pour To Solid In Extrusion Profile Seal At The Outlet. *All The Filters Shall Be Individually Tested According To En1822 And Computerized Scan Test Report Should Accompany Each Filter.*The Filter Shall Be Held In Place Utilizing ‘Hold Down’ Devices With The Ceiling Grid Using Channel On The Filter Top And T-Bolts In The Ceiling Grid Pressing The Filter Against Ceiling Grid. *All Filter Modules Shall Be Complete With Air Inlet Collar Of 12” Diameter ( Approx. ) . *Top Sheet Should Be Of G.I. / Aluminium Single Piece Drawn With Seamless Neck. In Case, Neck Is Not Seamless, Neck Joint To The Top Sheet Be A Proper Leak Proof Joint And With The Capability Of Supporting A Person Standing On The Top Surface. *Filter Media Shall Be Bonded To Extruded Aluminium Cell Sides.Dimensions :1210 Lx 600 D X 60 Mm Hepa Filter Are Rated 99.97% Efficiency In Removing 0.3? Or Larger Particles. Leak Free In Accordance With Latest I.E.S Recommended Particle.The Filter Media Is Micro Glass Fibre With Poly-String Separator, Sealed To Casing. The Filter Guard Is Provided With Diamond Pattern Expanded Sheet For Protection. , Ii ) Fan Filter Modules With Ulpa Filters For Class 100 : The Fan Filter Units Ffu’S Are Self-Powered Grid Module With Modular Design, To Fitting In Standard T Grid Ceiling. Total Height Is 320Mm. The Fan Filter Module Is U.L Listed And Ce Certified. Ffu Speed Can Vary From 0.2 To .5M / S And Air Flow Rate Vary From 460-760 Cfm. The Sound Level Will Be 55Db’S When Measured From 760Mm Below From Filter Face. The Vibration Level Is 0.9Mils. The Fan Motor Drive Will Be Direct Drive, Forward Curve Centrifugal Type With Sealed Bearing. The Motor Will Have Permanent Split Capacitor Type, Rated For Continuous Operation With Thermal Overload Protection With Two Speed Switch. The Power Requirement Is 230V, 50Hz Single Phase With Maximum Current Of 1.9A With 280Watts Power Input. The Fan / Motor Assembly Is Capable Of Delivering Air At Filter Pressure Of 9Mm To 23Mm Final State. These Ffm Will Have A Speed Controller For Increasing The Speed Of The Motor / Blower From Low, Medium And High. Dimensions :1220 Lx 610 D X 350 Mm H Ffu Material Of Construction : Al Zinc Alloy Hepa Filters Are Rated 99.997% Efficiency In Removing 0.12? Or Larger Particles. Leak Free In Accordance With Latest I.E.S Recommended Particle.The Filter Media Is Micro Glass Fibre With Poly-String Separator, Sealed To Casing. The Filter Guard Is Provided With Diamond Pattern Expanded Sheet For Protection. Dimensions :1210 Lx 600 D X 60 Mm H , M ) Return Air Grille With Collar Damper The Linear Diffusers / Grilles Shall Be Fabricated From Aluminum Extruded Sections. The Diffusion Blades Shall Be Extruded, Flush Mounted Type With Single Or Double Direction Air Flow. The Frame Shall Be Of Aluminum Extruded Section And Shall Hold The Louvers Tightly In Fixed Position. The Dampers As Described Under Grilles Shall Be Provided Wherever Specified. Return Air Grills With Damper At Room Side 800X400. , N ) Antistatic Pvc Flooring I ) The Cleanroom Flooring Shall Be Esd - Pvc 2Mm Thick And The Electro Static Dissipative Will Be Homogeneous Constructed Product Sliced From A Pressed Vinyl Block To Assure A Highly Flexible Tile Of Dense Construction, Dimensionally Stable, Extremely Hard Wearing, With A Completely Non-Directional Pattern. , Ii ) Esd Flooring Includes, Dedicated Earth Pit And Interconnecting Copper Strip 30X5 Mm Thick- 48 Rmt , O ) Cleanroom Lighting I ) Class 100 Cleanroom Lightscleanroom Teardrop Light Fittings For Iso 5 ( Class 100 ) And Surface Mounted Fittings To Be Provided Throughout The Facility To Achieve The 400-450 Lux Lighting Levels. The Teardrop & Surface Mounted Light Fittings Shall Comprise Of A Powder Coated Extruded Aluminum Body And Clear Acrylic Diffusers. Uv Filtration Film Having 350-400 Nm Thickness To Be Applied On Lights Or Uv Tube Sleeves Shall Be Used , Ii ) Class 1000 Cleanroom Lights: Supply And Installation Of Cleanroom Compatible Led Lights. The Envisaged Lighting Level In Clean Rooms Is 500 Lux, At 90 Cm Above The Floor. Lights Must Be Openable Towards Inside The Room. Dimensions: 600X600 Mm Power: 42 W , P ) Air Showersupply Of Ss304 Single Entry Class 10, 000 Airshower 1500 Lx 1500 D X 2300 H In Mm* Dimensions:1500 Lx 1500 D X 2300 H In Mm* Material Of Construction: Ss304 1.6 Mm Thick* Class 100 Compatible* Two Stage Filtration Eu6-Prefilter ( 95% Down To 5 Micron ) For Return Air & Fresh Air Intake* Doors: Ss304, 1, 6 Mm Thick Doors With Double Walled Flush Glass View Panels & Door Closer* Statically & Dynamically Balanced Motor- Blowers With Suspension Arrangement To Reduce Noise Level For Suction And Booster* Differential Pressure Gauge: 1 No. * On / Off Switches* Pao Test Port* Door Interlock Systems – To Ensure That Both The Doors Cannot Open At The Same Time & To Ensure That Both The Doors Will Be Locked During The Time Air Flow Is On.* Timer For Setting Air Shower Operation Time ( Settable For 30 Seconds To 5 Minutes ) * Emergency Stop Button* Straight Entry – Straight Exit / 90° L Type Door Opening * Automatic As Well As Manual Working. , Q ) Static Pass Box Dimensions 600X600x600 In Mmmoc: Ss304 , R ) Sterile Garment Storage Cabinet Supply And Installation Of Ss304, 1.6Mm Thicksterile Garment Storage Cabinet 1200X600x2100 In Mm , B ) Cleanroom Hvac A ) Air Handling Unit I ) Class -100-Ahu- Ahushall Be Of Double Skin, With 45+5 Mm Thick Puf Insulation Sand-Witched Panel, 0.8 Mm Thick Percolated Gss Outer Skin And 0.8 Mm Thick Plain Gi Sheet Inside. The Density Of Puf Insulation Shall Be Minimum 38 Kg / M3.The Casing Shall Incorporate Thermal Break Profile Aluminium And All Other Necessary Design Features To Ensure That Condensate Does Not Occur During All Seasons.Supply Air:4.853 M3 / S, Return Air:4.1 M3 / S , Fresh Air:0.735 M3 / Stotal Fan Static:150 Mm Wg, Cooling Coil Suitable For Chilled Water / Refrigerant Capacity:40 Tr, Heating Coil Capacity:76 Kw , Ii ) Class -1000-Ahu- Ahushall Be Of Double Skin, With 45+5 Mm Thick Puf Insulation Sand-Witched Panel, 0.8 Mm Thick Percolated Gss Outer Skin And 0.8 Mm Thick Plain Gi Sheet Inside. The Density Of Puf Insulation Shall Be Minimum 38 Kg / M3.The Casing Shall Incorporate Thermal Break Profile Aluminium And All Other Necessary Design Features To Ensure That Condensate Does Not Occur During All Seasons. Supply Air:4.382 M3 / S, Return Air:2.733 M3 / S , Fresh Air:1.649 M3 / Stotal Fan Static:150 Mm Wg, Cooling Coil Suitable For Chilled Water / Refrigerant Capacity:40 Tr, Heating Coil Capacity:57 Kw , B ) Chiller Unit ( 2W+1 S ) Supplying, Installing, Testing And Commissioning Of Ahri Certifiedair Cooled Scroll Water Chilling Units Of 40 Tr Capacity ( Actual ) Complete With Twin Screw Design Compressor With Star-Delta, Squirrel Cage Induction Motor, Starter Panel Machine Mounted, Water Cooled Condenser, Insulated Chiller, Flow Switch At Chiller And Condenser, Neoprene Pads, Integral Refrigerant Piping And Wiring, Bms Interface Unit Modbus, Counter Flanges Along With Flanged Connection For Condenser And Cooler Water In / Out Connections, Complete Charge Of Refrigerant And Oil, Accessories As Required And Called For, Automatic And Safety Controls Mounted In Central Micro-Processor Based Console Panel And All Mounted On A Steel Frame Complete As Per Specifications. Motor Shall Be Suitable For 415±10% 50 Cycles. 3Phase Ac Supply And Motor Cable Terminal Box Shall Be Suitable To Connect Copper Cabling. Refrigerant Used Shall Be Ozone Friendly Hfc134a / R410a As Detailed In Specifications. First Chiller Shall Be Factory Tested At Design Conditions At 100%, 75%, 50% And 25% Load. Cooling Capacity: 40 Trwater Flow-900 Lpmlpmsupply Water Temp. In Deg C- 5-7 Deg C Return Water Temp In Deg C-12 Deg C , C ) Chilled Water Pumps For Chillers ( 1 W+1S ) I ) Chilled Water Pumps Horizontal & Centrifugal Type Pumps. Supplying , Installation, Testing And Commissioning Of The Pumps Shall Be Horizontal, Close Coupled , Single Stage , Centrifugal , End Suction With Backpull Out Design. Hence , The Rotating Unit Can Be Removed And Serviced Without Disconnecting The Suction And Discharge Piping. The Pump Shall Be Balanced Statically And Dynamically. The Pump Are At Constant Speed And Suitable For Vfd Drive. The Noise Level Shall Not Exceed 75 Dba At 1M From The Source.The Pumps Shall Be Bms Compatible. Flow Rate:900 Lpm, Total Head: 30 M, Moc: Body : Ci, Impellor: Ss304 , Ii ) Chilled Water Piping With Al. Cladding Insulation: Chilled Water Piping With Al Claddingshall Be Installed For: Ahuand Pumps. Moc Of Pipe Shall Be Sch10 Ss304 With All Accessories , D ) Gi Ducting Supply, Installation, Testing & Commissioning Of Pre-Fabricated Gi Sheet Metal Ducting ( Prefabricating Ducting Means Duct Fabrication On Cnc Machines ) Complete With Gi / Ms Supports ( Complete Supporting Structure To Install Ducts At Site ) With Fully Threaded Gi Rods, Gi Nuts And Bolts ( With Check Nuts Wherever Applicable ) , Vanes, Splitters, Thermal Isolation Blocks, Etc. As Per Drawings And Smacna Standards For 4 Inch And 2 Inch Pressure Class. Ducting Will Have Ductmate Flanges With Food Grade Rubber Gasket Between Theflanges. All Duct Supports Shall Have Minimum 3 Mm Thk. Insulated Tape Between Support And Duct. All Ducting Seam To Be Sealed With Rtv Sealant. The Zinc Coatingthickness Should Not Be Less Than 120 Grams / Sq, Mtr ( Gsm ) .All Duct Joints Shall Be Inspected For Leakage. I ) 24G , Ii ) Ms Supporting System , E ) Insulation Supply, Installation Ofnitrile Rubber Insulation With One Side Aluminum Faced. The Insulation Material Shall Be Fm Approved. The Insulation Shall Have Fire Performance Such That It Passes Class ‘O’ As Per Bs 476 Part 6 For Fire Propagation And Class 1 As Per Bs 476 Part 7 For Surface Spread Of Flame. All Insulation Joints ( Including Flange Joints ) To Be Sealed With 3 Width Self Adhesive Tape. I ) 19Mm Thick Insulation , Ii ) 16Mm Thick Insulation , F ) Dampers Manual Low Leakage Volume Control Damperof Class 4 As Per Bs En 1751 ( Permissible Leakage Allowed -6.2 L / S / Sq M, Test Certificate Required ) And Shall Be Made Out Of 18G Gi, Opposed Type Multi Aerofoil Shape Blade With Handle And Wing Nut, Clearly Marked With Open / Close, Percentage Open, Locking In Position And Sealing Arrangement For Branches. The Dampers Should Be Suitable For Manual & Motorized Operation And Shall Have The Plain & Rigid Base Plate To Install Actuator. Damper Shaft Rod Shall Be Square. I ) Gi Round Damper 250Mm Dia 18 G , Ii ) Flexible Insulated Duct 200 Mm Dia , G ) Flexible Canvas Connection Supply Of 150 Mm Deep Antivibration Flexible Joints Made Out Of Imported Fire Resistance Flexible Double Canvas Sleeve With Extruded Aluminium Frame / Flanges On Both Sides , C ) Cleanroom And Hvac Electrical A ) Hvac Electrical Dbsupply, Installation, Testing And Commissioning Of Floor Mounted Type Vfd Electrical Control Panel And Provision Formicroprocessor Controller With Hmi ( Refer To The I / O Points Mentioned In The Technical Specifications Document Under Section 4.3: Plc Panel With Hmi ) Provision For :Safety Interlock I ) Ahu Blower-Vfd-6 Kw, 3 Ph , Ii ) Chiller Unit-41 Kw, 3 Ph-Contactor , Iii ) Heater- Ssr-60 & 80 Kw 3 Ph , Iv ) Pumps-8 Kw, 3 Ph- Contactor With Star Delta Starter , V ) Exhaust Blower-8 Kw 3 Ph, -Contactor With Star Delta Starter , Vi ) Process Cooling Chiller-8 Kw, 3Phcontactor , Vii ) Compressed Air Plant -8 Kw, 3 Ph Contactor , Viii ) Di Water Plant- 3 Kw , 3 Ph Contactor , Interlocks I ) Flow Switch , Ii ) Ahu Door Interlock , Iii ) Chiller-Pump Interlock , Iv ) Smoke And Fire , V ) Thermal Interlock , Vi ) Access Control Emergency Interlock , B ) Cleanroom Electrical Sub Db - Ups Db And Raw Power Db Supply, Installation, Testing And Commissioning Of Wall Mounted / Floor Mounted Type Distribution Board. Provision At Db: I ) Cleanroom Sub Db - 2 Nos ( 1 Ups, 1 Raw Power ) , Ii ) Cleanroom Lighting ( 40W ) - 1 Ph , Iii ) Cleanroom Power Points ( 5 / 15A ) , Iv ) Fan Filter Units ( 2.5 A ) - 1 Ph , V ) Air Shower ( 1.5Kw ) - 3 Ph , Vi ) Sterile Garment Cabinet ( 6 A ) - 1 Ph , Vii ) Static Pass Box ( 6A ) - 1 Ph , Viii ) Access Control System ( 6A ) -1Ph , Ix ) Cctv - 1Ph , X ) Clear Room Equipments: 3Ph 32 A , Xi ) Cleanroom Power Points:1Ph 5 / 15 A Power Points , C ) Electrical Cabling And Accessories Hvac Cabling: Hvac Cabling Shall Be Laid In Metal Trunking ( Electrical Incoming Power To Hvac Panel, Sub Db Will Be Provided By Iitm ) I ) Cabling For Ahu Blower-6Kw- 2Nos.-4 Mm2, 4 Core Armored Cable , Ii ) Cabling For Ahu Blower Interlock And Emergency Light- 2Nos.- 2.5Mm 2, 3 Core Cable , Iii ) Cabling For Modulating Valve- 2Nos.- 1.5Mm 2 Shielded 3 Core Cable , Iv ) Cabling For Heaters-3 Ph , 60 Kw & 80 Kw 2Nos.6Mm 2, 3 Corearmored Cable , V ) Cabling For Chiller- 41 Kw-3Nos.- 25Mm2, 5 Core Armored Cable , Vi ) Cabling For Pumps- 8 Kw-2 Nos.-4 Mm2, 4 Core Armored Cable , Vii ) Cabling For Process Cooling Chiller- 8 Kw-1 Nos.-4 Mm2, 4 Core Armored Cable , Viii ) Cabling For Compressed Air Plant- 8 Kw-1 Nos.-4 Mm2, 4 Core Armored Cable , Ix ) Cabling For Exhaust Blowers- 8 Kw-2 Nos.-4 Mm2, 4 Core Armored Cable , X ) Cabling For Di Water Plant- 3 Kw-1 Nos.-2.5 Mm2, 4 Core Armored Cable , Xi ) Cabling For - Flow Sensor- 2 Nos.1.5Mm2 Shielded 3 Core Cable , Xii ) Cabling For - Room Temp And Rh- 2 Nos.1.5Mm2 Shielded 3 Core Cable , Xiii ) Cabling For - Thermal Sensor-2 Nos.-1.5Mm2 Shielded 3 Core Cable , D ) Cabling For Cleanroom Equipments Cabling For Cleanroom Equipments Shall Be Layed Through Pvc Dado I ) Cabling For Cleanroom Lights-30 Nos- 2.5Mm 2, 3 Core Cable , Ii ) Cabling For Fan Filter Units-16 Nos.- 1.5Mm 2, 3 Core Cable , Iii ) Cabling For1ph Power Points-30 Nos.-2.5Mm 2, 3 Core Cable , Iv ) Cabling For 3Ph, 32 A, 5 Wire , Power Points - 10 Nos- 4Mm2, 5 Core Cable , V ) Cabling For Air Shower- 1 Nos-2.5Mm 2, 5 Core Cable , Vi ) Cabling For Garment Cubicle- 1 Nos, .- 2.5Mm 2 , 3 Core Cable , Vii ) Cabling For Access Control System-2 Nos.- 1.5Mm 2, 3 Core Cable , Viii ) Cabling For Cctv- 11 Nos-Cat 6 Cable , Ix ) Earthpits , D ) Process Utilities A ) Gas Lines For N2, Ar And O2supply And Installation Ofuhp Gas Lines Double Cylinderauto Changeover Over Panel For N2, Ar & O2 I ) Double Cylinder Auto Changeover Panel For N2- 1 Nos. , Ii ) Single Cylinder Auto Changeover Panel For Ar- 1 Nos. , Iii ) Single Cylinder Auto Changeover Panel For O2- 1 Nos. , Iv ) 1 / 4 Ss316 L Ep Pipes , V ) Tap Off Points With Diaphragm Valve, Regulator And Gauge , Vi ) Supporting System And Clamps , Vii ) Cylinder Mounting Accessories , B ) Compressed Air ( Cda ) System I ) Supply Of Compressor Supply Of Oil Free And Moisture Free Scroll Compressor 9 Cfm Capacity, 10 Bar Pressure Rating , With 150 L Storagetank , Ii ) Supply And Installation Of Compressed Air Line: A ) Moc: Ss316l3 / 4 -50 Rmt , B ) Tap Off Points: Tap Off Points With Isolation Valve And Regulator , C ) Supply & Installation Of Process Cooling Water System I ) System Must Have Working And Stand By Pumps Of 50-60 Lpm At 17-19 Deg C At 4-5 Bar Pressure, Storage Tank Of 400 L, All Ss304interconnecting Pipes And Valves & Control Panel, Moc: Moc Of The System Ss304 , Ii ) Supply & Installation Of Process Cooling Water Distribution A ) Moc Of Distribution Lines: 1 Upvc Sch 80 , B ) No. Of Tap Off Points ( Tap Off Points Should Have Ball Valve, Gauge, Flow Meter, Prv ) , D ) Utility Drain Line I ) Utility Drain Line Shall Be Pp Sch 80 Dn 50Mm , Ii ) Tap Off Points , E ) Polypropylene Wet Chemical Bench Polypropylene Wet Chemical Bench-1800 Wx 950 D X 2300 H Mmmoc: Polypropylene Fire Retardant Utilities:N2, Di Water , Ro Water Connection, Drain, Power Points5 / 15A- 4 Nos, Lights- 2 Nos, Storage Trolley- 2 Nos. , F ) Scrubber And Exhaust Ducting Wet Scrubber I ) Pp+Frp Packed Bed Type Wet Scrubber For 3500 Cfm Capacity , Ii ) Pp+Frp 3+2 Mm Thick Ducting 300Mm Dia. , Iii ) Ppfrp Blower 2500 Cfm Capacity @ 350 Mm Total Static , Iv ) Tap Off Points With Vcd Dia. 200 Mm , G ) Fume Hood For Solvents Moc: Polypropylene Fire Retardant Dimensions: 1200 W X950 D X2300 H In Mmutilities:N2, Di Water , Ro Water Connection, Drain, Power Points5 / 15A- 4 Nos, Uv-Lights- 2 Nos, Storage Trolley- 2 Nos. , H ) Blower And Exhaust Ducting Blower Moc: Ss304 I ) Blower Capacity: 1000 Cfm @ 75 Mm Total Static , Ii ) Duct Moc: Ss304 200Mm Dia With All Accessories-25Rmt , Iii ) Bibo Box For Activated Carbon Filter , I ) Di Water Plant A De-Ionized Water System Consisting Of A Generation And Storage System For Generating And Storing Type-I ( Resistivity = 18 M?-Cm ) And Type-Ii Water ( Resistivity = 1 M?-Cm ) Should Be Provided. In Addition To The Resistivity Metrics, Plant Shall Be Recirculatory Type And Pressure Depended Type. Di / Type I Water Flow Rate:1-2 Lpm@ 1.5-2 Bar Ro / Type Ii Water Flow Rate:2 Lpm @ 1.5-2 Bar , J ) Di Water Pipingdi Water Piping Moc: Pp Pp Dn 25Mm Pipe With All Accessories- 70 Rmttap Off Points- 3 Nos.Tap Off Must Have Isolation Valve- 3 Nos. , E ) Spin Coater Programmable Spin Coater • Bowl-Shaped Process Chamber Which Can Hold Size 6 ( ~150 Mm ) Diameter Wafers Or 5 ( ~125 Mm ) Square Substrates • Ac Brushless Motor Featuring Bi-Directional Rotation / Agitation, High Acceleration, And A Wide Speed Range • Digital Process Controller For Easy Programming • Speed : 1-12, 000 Rpm • Accuracy <+-0.5% Of Full Speed • Time: 1 Second To 99 Minutes 59.9 Seconds In 0.1 Second Increments • Programs: Twenty Multi-Step Programs Or Manual Mode • Real Time Display Of Rpm, Time And Program Stamps • Input And Control Through Soft Touch Keypad • Acceleration: Up To 13K Rpm / Sec With Standard Chuck ( Programmable In 1 Rpm Increments ) • Pc Interface Software To Be Included • Fluid-Control Lid Directs Materials Towards Rear Drain — No Drips Should Be Encountered When Opening Chamber • Chemically-Resistant Lid With Ø3 / 4; ( Ø19 Mm ) Center Opening • Npp Vacuum Chuck For Ø50 Mm Through Ø150 Mm Substrates • Npp Fragment Chuck Adapter — Fits Over Above Chuck For Holding 10 Mm Through ~50 Mm Pieces Ø1.5; ( Ø38 Mm ) Npp Drain Port And Nitrogen Purge • Polypropylene Drain Container To Store Exhausted Drain Reservoir • With Necessary Interlock, Latch And Lock For Safety Of The Door • With Oil-Less Vacuum Pump ( 220 Vac, 50 / 60 Hz ) And Inlet Port , F ) Life Safety And Security System A ) Cctv - Cameras , B ) Access Control System For 1 Door , C ) Door Interlock System For Air Lock Room , D ) Smoke And Fire Detection System , E ) Local Area Network , F ) Telephone , G ) Local Fire Extinguishers : Suitable For A, B, C Fire Classifications 5 Kg Capacity Suitable For Cleanroom Application , G ) Cleanroom Furniture I ) Ss316l Cleanroom Cross Over Bench 2100X400x550mm , Ii ) Ss316l Working Table 1500X900x750mm With 2 Power Points , Iii ) Ss316l Tables With Under Table, Table Dimensions 1200X750x750, Under Tablecubicles 500X700x700, 2 Drawers And 1 Door , Iv ) Class 100 Compatible Cleanroom Chairs , V ) Class 100 Compatible Cleanroom Stools , Vi ) Polypropylene Chemical Storage Cabinet 900 W X550 Dx2100 H In Mm , Vii ) Ss316l Cleanroom Bins-Dia 350X650 H In Mm , H ) Room Differential Pressure Gauges , I ) Temp And Rh Indicator , J ) Engineering, Design And Drawings , K ) Documentation , L ) Commissioning And Validation
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
9.
Defence #10003682 AOC
Tender For Demolition And Re-Construction Of Smc Building At Afs Yelahanka On Epc Mode; 2 GENERAL SUMMARY NOTE: Schedule ‘A’ Part II to IX are prepriced by MES under Ser No. 2 to 9. Bidders shall insert their lumpsum amount in the Green coloured field under Col-6 only. 3 Lumpsum price worked out by the contractor for “Site Clearance as listed in Schedule ‘A’ Part - II. 4 Lumpsum price worked out by the contractor for Road/Path/Hardstanding as listed in Schedule ‘A’ Part - III. 5 Lumpsum price worked out by the contractor for Area Drainage as listed in Schedule ‘A’ Part - IV. 6 Lumpsum price worked out by the contractor for “Sewage Disposal” as listed in Schedule ‘A’ Part – V. 7 Lumpsum price worked out by the contractor for “Fencing” as listed in Schedule ‘A’ Part – VI. 8 Lumpsum price worked out by the contractor for “External Water Supply/Hot Water Supply” as listed in Schedule ‘A’ Part – VII 9 Lumpsum price worked out by the contractor for “External Electric Supply” as listed in Schedule ‘A’ Part –VIII 10 Lumpsum price worked out by the contractor for “Demolition of existing buildings” as listed in Schedule ‘A’ Part – IX 11 Sch A Part - I : BUILDINGS OR WORKSDESIGN & CONSTRUCTION OF TWO STOREY (G+1)SMC BUILDING, AMBULANCE PARKING SHED AND DEMONSTRATION AREA INCLUDING ALL INTERNAL SERVICES AS DETAILED IN SCOPE OF WORK AND OTHER DOCUMENTS OF THE TENDER,COMPLETE ALL AS SPECIFIED AND SHOWN ON DRAWINGS. 12 SCHEDULE A Part- X (FITTINGS AND FIXTURES & MISC ITEMS) 13 ROADMaterial and labour for preparation of new road surfaces and applying reflective thermoplastic road marking paint (White or golden yellow) of minimum 2.50 mm thick (conforming to BIS-3262), single coat as in centre line and edge line road marking of 150/ 100mm width using HOT MARK by indigenous modern propelled road marking machine as directed including all ingredients such as binder, glass beads, titanium dioxide, calcium carbonate, inter filler as specified in table 803.4of MORTH specification,thermoplastic requirement for glass beads shall be as specified in (intermix) type-I, MOST/BS 6088Aand road marking shall done as per provisions contained in IRC-35-1997 complete all as specified and as directed. 14 FENCINGSupply and fix Stainless steel 304, 12 inch size each letter for Bilingual name board (Hindi-14 Nos letters and English-21 Nos letters) embedded in Granite on both gate complete all as specified and directed. 15 EXTERNAL WATER SUPPLYMaterial and labour for cutting existing 150mm bore water mains and inserting TEE 150mm x 100mm including necessary fittings, joints etc for connection of TEE complete all as specified and as directed. 16 Supply and fix Cast iron sluice valve flanged of class 1.0 PN, 80mm complete all as specified and as directed, 17 Supply and fix 80 mm dia cast iron body with flanged ends drilled ISI marked as per IS 14846:2000, PN 1.6 with brass spindle and check nut including operating wheel etc and fixed with flanges both end and new bolt, nuts, washers and rubber insertion packing complete all as specified and as directed. 18 EXTERNAL ELECTRIC SUPPLYReturning and filling of trenches in two parts (i) using riddled soil obtained fromexcavated soil upto depth of 30cm (8cm below cable and remaining above cable) for cushioning of cable and (ii)refilling the trench of remaining depthwith normal excavated soil all as specified and directed.Note: - Excavated soil shall be riddled by using sieve to separate composite particles etc as per IS 1255-1983 and refilling in trenches as in cable cushioning. 19 Material and labour for Boring of holes under road, pavement, hardstanding by trenchless technology using ultrasound technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure Complete all as specified and directed. 20 Supply and installation , testing and commissioning of HT 11 KV, rated voltage 12 KV,630 Amp, 21 KA / 3 Sec outdoor type extensible internal arc 21 KA for 1 sec for Tank floor mounted with internal copper busbar, SF6 insulated completely motorized 4 way RMU consisting of 01 Nos VCB 630 Amps as incomer and 03 No 630 Amp VCB as outgoingSCADA compatible, over load and earth fault protection relaywith air insulated metering module (MFM for VCB feeders) all live parts busbar ,VCB connections of RMU shall be inclusive in one SF6 tank to avoid multiple inter connections SF6 tank shall be sealed for life robotically welded non magnetic and non ferrite stainless steel grand 304 min 2.5 mm thick having IP-67 degree of protection filled with SF6 gas has insulation with leakage rate less than 0.1% per year tested as per IEC 62271 200 I No fault passage indicator (FPI) required for complete unit manual welding or heremetic ceiling of tank shall be not accepted . The unit shall have front cable entry (suitable for termination of 1 hr x 3C 95.120/ 150 Sqmm cable) for easy of installation and shall have site replaceable bushing for easy of troubleshooting during break down. RMU should be completed with all accessories such as terminal boots, VPIS , cable supports , all front cable terminations , mechanical indications vacuum circuit breakersON/OFF, Manometer as per with IEC standards 62271200, 60056, 60129, 60265, 60298, 60420, 60529 & 60694 altitude of installation upto 1000 m as per IEC 60120bushing bolted type top monitored outside the tank for connections of external busbar also the outer includes shall cover the full length of the switchgear , to ensure IP3X + IP-54 protection for cable boxes the unit shall be internal arc proof 24 KA for 1 sec with AFLR classification tested and totally safe for human being. 21 The gas release and personnel safety from internal arc shall not dropped on plinth design the release of gas to be from the top the unit . So that even if the person is operating the unit opening the cover and there are personnel near the side of the RMU / plinth top release will ensure their safety. The hot gas release in case of an internal arc, in No of case should be from any side or bottom of the unit as the same if unsafe for operating personnel / pedestrian or general public. Bidder shall provide type test report to be prove compliance to the internal arc fault IAC-AFLR as per IEC62271-200 internal arc testing shall be done with enclosure door in open conditions , with switching devise in operations mode as per specified standard RMU.(a) 01 Nos Incoming 630 AmpsVCB,motorised vacuum circuit breaker, triple pole single break 3 position (On, Off and earth having STC capacity 21 KA for 3 seconds with copper busbar and copper earth bar fitted high fixed type voltage indicator device as per IEC61958-1 fully rated with earth switch spring assisted mechanism with built in operating handle, arc proof hinged type cable cover air insulated cable boxes and boots suitable for bottom front entry termination of 3 core cable 95/120/185 sqmm. (b) 02 Nos Outgoing 630 Amps motorised vacuum circuit breaker, triple pole single break 3 position (On, Off and earth having STC capacity 21 KA for 3 seconds with copper busbar and copper earth bar fitted high fixed type voltage indicator device as per IEC61958-1 fully rated with earth switch spring assisted mechanism with built in operating handle, arc proof hinged type cable cover air insulated cable boxes and boots suitable for bottom front entry termination of 3 core cable 95/120/185 sqmm.(c) Bus connected PT unit-01 No for metering consisting of following:- (i) Type M : Air insulated metering module 12 KV, 630 A 21 KA for 3 sec.(ii) 3 voltage transformers of the ratio 11KV/1.732/110V/1.732.25VA class 1.0 with HT fuses on primary side and MCB on secondary side. 22 (iii) 3 Digital MFM with 485 port to measure Amps, Volts, Frequency, PF, KWH, KVAR.(iv) 1 LED bulb for illumination. (v) 1 Space heater with thermostat. (vi) 1 RYB Phase indicator. (vii) 1Cable support bus bar, stand for 3 Way unit, 1 Manometer & 1 Preparing Handle. (viii)1 Set bushing for external busbar connection along with bus bar cover & sleeved bus bars for coupling. (ix) 2x12 V Battery with charger of suitable burden for motor operation, input 230 V AC & output 24 V DC.(d)Capacitive Voltage indicator fixed type VPIS 9-15 KV. (e) Necessary inter locking arrangement for safety and operation. (f)One No Operating handle for manual operation. (g) PCC 1:2:4 type B1 using 20mm graded stone aggregate for foundation and bus duct of cable for RMU as per recommendation of manufactures & as directed by Engineer-in-charge. (h) Safety interlocks shall be provided as relevant IEC/IS standard and manufactures directions. (j) Above switchgears shall confirm to all relevant IEC/IS standard.(k) Manual operation of Vacuum Circuit Breaker should be possible without dismantling the motor from RMU. The motor should be fitted in such a way that it should not be required to dismantle during manual operation.(l) Coupling of RMU and metering module should be with the help of bolted type arrangement so that the coupling at site shall be easy. Plug in type bushing shall not be acceptable.(m) Minimum 3 Module should be accommodate in one tank to avoid multiple coupling at site. (n)Having following additional facilities:-1. Trip circuit supervision. 2. Disturbance recorder. 3. Event log with date and time.4. Measurement and control feature. 23 (o) Current Transformers (CTs) of dual ratio 50/25-5A of 15 VA output, accuracy class 1.0 for metering instrument and 5P10 for 15 VA accuracy for over current and earth fault protection - sets of 03 Note:-(i) Any other parts/items not specified above but have been considered essential for smooth and safe functioning of the RMU system shall be included in the items and are covered against the quoted rate.(ii)Cable compartment shall be provided at the front side with front bolted type box covers providedwith an inspection window forenabling operator to have visual inspection without operating cover in live condition for all incoming and outgoing RMU panels.(iii) Complete with internal and external connection with each other or as per ground requirement.(iv) Drawing and Design drawing shall be submitted for approval of Accepting Officer before placing Order.Following additional equipment delivered separately or mounted in respective panel.(i) Cable support bars, standard for 4-Way unit.(ii) Manometer.(iii) Operating handle. 24 Supply and fix 7 meter high hot dipped octagonal poles with 130mm bottom dia & 70mm top dia made up of 3mm thick HT Sheet alongwith base plate of size 200x200x12mm including foundation bolts & bracket of size M20x600mm EN 8 grade J type foundation bolts and numbering of poles, in white paint over black painted back ground at a height of 1.5m from bottom of pole with 5 cm large bold letters 2 (inch) wide withetc complete as required andall as specified and directed. complete accessories as required complete all as specified and as directed. 25 Supply and fix street light fitting 72 watt LED, new generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having top opening separate driver compartment with IP66 protection including GI Bracket of suitable size required for fixing LED light on pole along with nut and clamp complete all as specified and directed.Note :- Rates quoted by contractor are deemed to be inclusive of 3 core cable pvc insulated unsheathed copper multistranded conductor ISI marked from MCB box to street light all as specified. 26 Supply and fix pole box of size 450x 300 x 200 mm fabricated out of 2 mm thick MS Sheet having 4 Nos aluminium busbar of suitable size with 1 No. MCB SP 10 Amps front openable hinged cover outdoor type weather proof suitable for mounting on steel pole including fixing MS clamp02 Nos with nuts, bolts and washers complete all as specified and as directed. 27 Earthing complete with galvanized steel earthplate electrode 600 mm x 600 mm x 6.00 mm thick buried directly in ground vertically in a pit (earth pit of depth not less than 2.25 metre below ground level) with top edge of the earth platenot less than 1.50 metre below normal ground level surrounded from all sides by mixture of charcoal and common salt 15cm thick each layer and electrode connected to and includinggalvanized iron earth strip, 32 x 6 mm (earth lead) by means of bolts, nuts, check nuts and washers of galvanisedsteel protection pipe light grade 40mm dia and GI pipelight grade 20mm dia bore for watering, funnel with wire mesh, earthing chamber with PCC (1:2:4) type B-1 using 20mm graded stone aggregate, 80 mm thick precast RCC 1:1.5:3 type A-1 cover duly reinforced with XPM (weight not less than 3 kg/sq m) and frame including all excavation and earth work all as shown in electrical plate No 3 connected to earthing test point including testing on completion complete all as specified and as directed.Note : The unit rate includes for 40mm light grade protection pipe and GI earth strip 32 x 6mm from top of earth plate upto 7.50 metre above ground level.The earth pit shall be constructed atleast 1.5m away from the top of earth electrode. 28 Earthing with galvanized steel earth plate electrode 600mm x 600mm x 6mm thick, buried directly in ground (earth pit not less than 2.25 metre deep below normal ground level) with top edge of the plate not less than 1.5 metre below normal ground level connected to galvanized iron wire 4mm earth lead by means of bolts, nuts check nuts and washers of galvanized iron or steel with protection pipe of GI, medium grade 15mm bore, watering pipe 20mm bore of GI medium grade, earth plate surrounded by alternate layer of coal dust and common salt 15 cm thick each layer all as per electrical plate No 3 of SSR Part-I and connected to earthing test point all as specified or indicated and testing on completion including funnel with wire mesh, earthing chamber with PCC (1:2:4) type B-1 using 20mm graded stone aggregate, 80 mm thick precast RCC 1:1.5:3 type A-1 cover duly reinforced with XPM (weight not less than 3 kg/sqm) and frame including all excavation and earth work etc. including testing on completion complete all as specified and as directed. Note :(i) Earth chamber shall be constructed at least 1.50m away from the top of earth electrode.The earth pit and pipe for watering shall be provided in slanting manner.The unit rate include for GI pipes, GI earth lead from top of earth plate upto 7.50m above ground level, including PCC, RCC work etc as specified in the item. 29 Supply, installation, commissioning and testing of feeder pillar board Kiosk type floor mounted, Outdoor type, fixed type, double door openable both rear and front side, weather, dust and vermin proofand compartmentalizedMain L.T Panel(CPRI approved) made out of M.S. CRCA sheet 3.15 mm & M.S. Base Frame Angle 75x40 mm duly painted with Light/ Siemens Grey Powder Coated Paint with 900 A TPN Copper Busbar (current density of Copper Busbar shall be 1mmx1mm=1.6 Amp.)Copper shall be Electric grade, Busbar supports shall be DMC epoxy Insulators.All Busbars & Incoming/Outgoing Links shall be covered/ insulated with Heat Shrinkable sleeves ofcoloured coded red, yellow, blue & black. Power & Control Wiring withCopper Flexible Wire (size of control wire shall be 2.5 sq. mm copper flexible for C.T. Circuit & 1.5 sq. mm for other circuits)as per specifications. Platform for the feeder pillar board with PCC 1:2:4type B-1, 15cm thick in foundation, Brick (sub class B) work in CM 1:6 rendering in cm 1:6 on exposed surfaces and 100mm thick PCC 1:3:6 type C1 using 20mm graded stone aggregate as in padding on top and grouting blots etc for panel. The platform shall be 450mm height above ground level and of adequate size leaving minimum 100mm all around the feeder pillar board with following :- 30 (a)ACB 415 Volts, 630 amp, rating 4 pole 50 KA rupturing capacity, microprocessor release -01 No.(I/C)(b) MCCB 415 Volts , 250 Amp 4P , 36 KA ,microprocessor release - 01 Nos (c)MCCB 415 Volts , 160 Amp 4P , 25 KA ,microprocessor release - 02 Nos(d) MCCB 415 Volts , 125 Amp 4P , 25 KA ,microprocessor release - 02 Nos(e)MCB415 Volts , 32 Amp 2P , 10 KA ,microprocessor release - 02 Nos(f)Voltmeter 0-500V digital type with selector switch 96mmx96mm square flush mounted- 01 No.(g)ampere meter digital type of size 96mmx96mm flush mounted CTs operated including CTs 0-630A with selector switch-01 No.(h) LED type/Neon type indicating lamps panel mounting type RYB-03 Nos.(i)fine wiring with single core PVC insulated conductor FLRS wire of suitable size copper conductor cable,thimble, lugs etc for instruments/indicating lamps-01Job. 31 Supply, fixing, testing & commissioning of LT panel board of size 1.1x1.1x.5 Mtr,weather proof, outdoor type powder coated, double door shutter, made out of CRCA sheet3.15 mm thickouter and 2.00 mm thick for inner door confirming to IS 8623 with angle iron 50x50x6 mm outdoor, floor mounting type with closedAluminium bus bar chamber including necessary insulator suitable for 3 phase, 4 wire 50 Hz AC,CPRI approved including provn of digital ammeter 0-350A,digital voltmeter 0-500 Volts, CTs of suitable ratio, indicator lamps R-Y-B,selector switches and internal wiring including making PCC block type 0.6 Mtr above ground level grouting etc all as specified and directed with the following Work alsoincludes provision of suitable size of cable glands, cable lugs, nut, bolts, washers etc The bottom portion of enclosure shall be minimum 100 cm above ground level of legs of angle iron ). 32 (a) Copper bus bar capacity 900 Amps for Phase-R-Y-B-3 Nos &neutral -1 No(b) ACB FP 36 KA 630 Amps- 1 Nos(I/C) (f) Digital Ammeter flush pattern type square dial 96 x 96 mm alongwith selector switch - 01 No and suitable CT ratio 0-630 Amps (g) Digital Voltmeter flush pattern type square dial 96 x 96 mm alongwithselector switch - 01 No 0-500 V(h) complete control panel wiring withstranded copper conductor of suitable size along with one set indicator lamp for R,Y & B for each incoming and outgoing feeder 33 Supply and fix Post top light of capacity 45Watt offering excellent uniform illumination and aesthetic in one go , made up of pressure die cast aluminium body and open PC Cover, IP 66 and IK-07 rating suitable for tall amid varied environmental conditions and for pole of dia 76mm colour temp 3000K complete all as specified and directed. 34 Supply and fix LED Bollard Light with unique concept LED in IP 66 with sustainable performance in all section of Capacity 9W, 220V, 50 Hz CCT- 3000K, 800mm Complete all as specified and as directed. 35 Supply, erection, testing and commissioning of 16M high mast shaft in two section suitable for 44m/sec wind speed along with head frame, luminaries carriage suitable for 8 luminaries in symmetrical arrangement and other accessories manufactured in factory including Supply of raising lowering system comprising double drum winch, 6mm diameter SS wire rope, trailing cable, connector, integral power tool motor, manual handle, junction box, lightning finial. (Wiring material from JB to individual luminaries & MCB in base compartment are not included and are a part of installation) complete all as specified and directed by the Engr-in-Charge. 36 Supply of fix single dome LED type dome aviation obstruction light complete all specified and directed by Engr-in-Charge. Make : Bajaj Cat No : BGAV302LED or its equivalent in make specified in PS. 37 Supply and fix foundation bolts 04 Nos 24mm dia 850mm length, manufactured from special steel along with nuts, washers, anchor plate and common template complete all as specified and as directed. 38 Supply and fix LED flood light 250 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all specified and directed by Engr-in-Charge. 39 DG SETSupply installation testing and commissioning of Silent type Diesel Engine Generating set 415 volts 320 KVA, 3 phase 0.8 power factor, 50 Hz,developing 434 BHP @ 1500 RPM ,self exicited , self regulated brushless AC generator including AMF panel, suitable for ambient condition at Yelahanka and confirming to condition under CPCB 4+, ISO 8528-1, 3046, IS 10002, BS 5514/5000 with capacity of 10% overloading for one hour in every twelve hour duration andincluding the following accessories :-Make : Kirloskar / Ashok Leyland/ Ruston/Cummins 40 (A) Alternator :-Synchronous alternator rated at 320 KVA suitable for continuous operation at 1500 RPM generating 415 volts at 0.8 p. f (lag) suitable for 50 Hz, three phase, 4 wire system. The alternator shall be brushless,single bearing,self excited & self regulated with an AVR .The alternator will be suitable for tropical climate and shall generally confirm to IS: 4722 : 2001 The salient features of the alternators are :-(a)+-1% voltage regulation (max) in static conditions.(b)IP: 23 protections with class ‘H’ insulation. · (c)Permanent lubricating bearing. · (d)Permissible overload of 10% for one hour in 12 hours of operation.(B) Diesel Engine: - Adquate capacity of Diesel engineliquid cooled to drive independently above alternator and after considering de-rating as per site conditions after generating and reducing power consumed by accessories directly coupled through flexible coupling multi cylinder multi stroke direct injection,cold starting 1500 RPM, as per relevant IS/BS complete with standard accessories all as specified and required for safe handling and operation. Salient features of accessories shall be as under :- i) Fly wheel with housingii) Cooling system :- Moulded radiator with fan & belts.iii) Cooling Liquid pump : - Centrifugal type belt driven.iv) Exhaust System :- Exhaust System complete with exhaust piping of suitable dia with MS pipe medium grade, Silencer : Residential typev) Fuel System :- Fuel injection system with fuel injectors, fuel injection solenoid switch controlled by governer electric operated/ (as recommended by OEM) for 1% speed /frequecy regulation.,Fuel filters, Fuel hosesvi) Lub oil System :- Lubricating oil filter,Lubricating oil pumpvii) Air Intake System :- Air intake Manifold,Air cleaner dry typeviii) Governer : Electronic typeix) Starting System :- Electric Self starter , including battery charging alternator 12 Volts DC.x) Batteries :- Batteries maintenance free of capacity 12 V, 150 AH- 02 No complete with copper conductor multistranded leads of suitable length fromself starter to the battary terminals complete with initial charge and initial fill of electrolyte all as specified. 41 xi) Generator Monitoring Panel : - Comprising of all standard items as per standard manufacturing, iginiton key switch and start / stop arrangement, indications for Engine parametes, hour run meter, RPM meter, Engine oil pressure indicator, coolant temperature indicator, Battery volt display.xii) Safety Controls : - Engine low lube oil pressure,high coolant temperature and over speeding of engine.xiii) Coupling arrngement : - Flexible couplingxiv) Accessories :- AVM Pads built- in or separtely mounted to manufactrer base frames.xv) Base Frame : - Base frame is fabricated either in ISMCor in sheet metal.The base frame is rugged in construction and designed for mounting Diesel engine and alternator close coupled, with cross members mounted on AVM. The base frame shall have provision for mounting of acoustic enclosure & control panel on it and lifting hook for complete seti.e. along with canopy, engine and alternator.xvi) MS/Steel flexible pipe line to and from the fuel tank to the DG Set.xvii) Battery Charger shall be provided as per manufacturer guidelines.xviii) 2 No battery of 12 V in charged condition with its leads. C)ACOUSTIC ENCLOSURE : Acoustic enclosure shall be powder coated and fabricated out of 16 SWG CRCA MS sheet. The silent canopy shall be of nut bolt type construction. Powder coating is done after seven-tank surface preparation process of sheet metal. Canopy panel and doors shall have inside lining of FIRE-RETARDANT foam as acoustic material & Rock wool for hot zone.Adequate hinged doors shall be provided to canopy, one door shall have glass window for control panel visibility. 42 (i)Manufactured by OEM suitable for 320 KVA DG Set.(ii) It Should be as per latest rules and regulations of Ministry of Environment and Forest and Pollution control board.(iii) The generating setbattery should be inside the enclosure.(iv) Fuel tank :-Daily service fuel tank of 8 hours of continuous operation, fabricated form 14/16 SWG sheet metal complete with drain, inlet and outlet connection and fuel gauge.(v) Construction Details/specification are as follows : - (a) Outer body :- CRCA Sheet of 1.6mm thick. (b) Doors :- CRCA sheet of 1.6 mm thick. (c) Sound Insulation :- 100 mm thick rock wool(minimum density 64kg/Cum)/ fire resistancefoam/puff as per OEM/ as per standard manufacturing to achieve desired decibel level.vi) The acoustic should be composite in construction and fully assembled integral unit.vii) The DG Set should be provided with external Emergency stop push button.viii) The enclosure should be suitably internally illuminated by LED Lamp fittings.ix) The noise level should be < 75 dB at 1m under free field conditions.x) The acoustic enclosure parts shall be of powder coated after pre treatment process.The base frame should be painted with epoxy based black shade.D) Control Panel :- Control panel shall befabricated from 16/14 SWG sheet and powder coated after seven tank treatment process:(i) Microprocessor based generator set monitoring and control system consists of LCD display and to monitor operator interface, fault history, alternator data, Engine data, porvision for service adjustement and caliberation of DG control functions, Engine controls, engine protective functions, alternator protective functions etc.(ii) Instrument fuses and control wiring. (iii) Indication lampsset for running and load on.(iv) Bus bar including suitable capacity of MCCB, including CTs, cable etc. 43 E) AMF Panel :- Automatic Mains Failure (AMF) Panel should be outdoor made of CRCA sheet 3.15 mm thick including necessary arrangement to Install, Testing and Commissioning complete all as per OEM recommendation. F) Civil Works :-All civil works including PCC (1:3:6) platform with a height of 60 cm above ground level and upto a width of 60 cm both sides of DG Set for easy operation of operator and necessary maint workand related foundationsfor panel and equipments including making good of distrubed area during installation and commissioning of genset . The depth and size of the foundation and PCC as recommended by the manufacturer.The contractor shall arrangeartificial load resistive for testing of DG Set at site and the cost is deemed to be included in the quoted rates.Note :- (i) The complete DG Set shall be procured from authorised OEM of the manufacturer of engine. A certificate in this connection shall be submitted to the GE.(ii) Circulation system toachieve desired inside temperature of acoustic enclosure, if required shall be provided as per OEM recommendation.(iii) The quoted rate shall be deemed to be inclusive of 12 hours test run at site as specified in PS and IS requirements in presence E/M Offr detailed by accepting officer, all testing arrangements/ equipments shall be made available by the contractor for tests.(iv) The quoted rate shall be deemed to be inclusive of first fill of lubricant oil, DHPP for 12 hours testing and final successful acceptance test.(v) Anything missed out above but technically required for efficient working of DG Set is deemed to be included in quoted rates.vi) Design / drawing of the AMF panel & DG SET showing the dimensions is to be obtained from DG SET/ panel board manufacturer / supplier & is to be got approved fromEngr-in-charge/GE before placing final order to the manufacturer.vii) The electrical connection of digital Multi Functional Meter in the AMF panel is to be done from load side so that monitoring of various parameters viz. Voltage, Current, KW, KVA, power factor, frequency etc can be done of both SEB mains & DG mains.viii)The quoted rate shall be deemed to be inclusive of first fill of engine oil & final successful acceptance test.ix) The quoted rate shall be deemed to be inclclusive one set of all types of filters , complete set of Maint tools & fuel refilling pump for filling fuel to DG set. 44 Earthing complete with galvanized steel earthplate electrode 600 mm x 600 mm x 6.00 mm thick buried directly in ground vertically in a pit (earth pit of depth not less than 2.25 metre below ground level) with top edge of the earth platenot less than 1.50 metre below normal ground level surrounded from all sides by mixture of charcoal and common salt 15cm thick each layer and electrode connected to and includinggalvanized iron earth strip, 32 x 6 mm (earth lead) by means of bolts, nuts, check nuts and washers of galvanisedsteel protection pipe light grade 40mm dia and GI pipelight grade 20mm dia bore for watering, funnel with wire mesh, earthing chamber with PCC (1:2:4) type B-1 using 20mm graded stone aggregate, 80 mm thick precast RCC 1:1.5:3 type A-1 cover duly reinforced with XPM (weight not less than 3 kg/sq m) and frame including all excavation and earth work all as shown in electrical plate No 3 connected to earthing test point complete all as specified and as directed including testing on completion.Note : The unit rate includes for 40mm light grade protecton pipe and GI earth strip 32 x 6mm from top of earth plate upto 7.50 metre above ground level.The earth pit shall be constructed atleast 1.5m away from the top of earth electrode. 45 REFRIGERATION & AIR CONDITIONING:-Supply, install, testing and commissioning hi wall inverter split units indoor/outdoor with invertercompressor with adjust power depending on load complete with cordless remote control unit and with in built air ionizer and plasma filter for better indoor air quality with minimum 5 star ratingAs perBEE guidelines and ISEERValue not less than 3.90 for air conditionerof capacity 1.5 TR includingall specified and directed by Engr-in-Charge. 46 Supply, install, testing and commissioning hi wall inverter split units indoor/outdoor with invertercompressor with adjust power depending on load complete with cordless remote control unit and with in built air ionizer and plasma filter for better indoor air quality with minimum 5 star rating as perBEE guidelines and ISEERValue 3.95 for air conditionerof capacity 2 TR complete all specified and directed by Engr-in-Charge 47 Supply, fixing, jointing and testing copper tubing with nominal diameter1-1/4 inch ofthickness not less than 1.2mmfor liquid line to connect with out door unit complete all as specified and directed by Engr-in-Charge. 48 Supply, fixing jointing and testing copper tubing with nominal dia meter3/8 inch of minimum thickness not less 0.9mm including expanded polythene foam insulation for external insulation of suction line for connecting with outdoor condensing unitcomplete all as specified and directed by Engr-in-Charge. 49 Material and Labour for fabrication of base stand made from MS angle iron of size 50mmx50mm, 6mm thick including necessary nuts, bolts & washers for mounting of outdoor unit of 1.5/2 TR capacity Split AC including painting with two coats of metal paint over one coat synthetic enameled black paint complete all as specified and directed by Engr-in-Charge. 50 Supply and fix PVC non-metallic flexible pipe of size 20mm dia alongwith fixing accessories such as saddles, pipe hook etc, for draining out the water from indoor unit complete all as specified and as directed by Engr-in-Charge. 51 HAND DRIER AND SOAP DISPENSERSupply and fix automatic hand drier machine suitable for single phase supply 230 Volts, 50 Hzwith ABS plastic body complete all as specified and directed. 52 Supply and fix automatic soap dispenser , 220 V , 50 Hz complete all as specified and directed. 53 UPSSupply, installation, testing and commissioning of online UPS of 30 KVA with isolation transformer and static bypass switch, Authomatic transfer switch of capacity 100 Amps 4 Pole) alongwith required sealed maintenance free batteries and batteries (12V 100 AH-32 Nos)with stand for backup of 30 min totally enclosed, free standing type, dust, damp and vermin proof, interconnections, wiring from normal sources upto UPS complete as required.I/P Voltage 360 V - 480 VNominal frequency - 50 HzFrequency range for online operation 45-50 HzI/P current range - 36A - 29AO/P voltage 415 VO/P current - 42A 54 LIGHTNING PROTECTIONSupply & fix Special standing seam fixure Clamp for Air terminal on Metal Structure -Site specific all as specified and directed by Engr-in-Charge. Make : TIRUMALA/JEF Cat No JICT54 or its equivalent in approved make. 55 Supply & fix Vertical Air Termination Solid aluminium with Base- 10 mm dia and 1000 mm long. Air Termination Base tested for conditioning, Ageing Test & Lightning impulse current withstand test: 100 kA of 10/350µs waveform in an accredited Third party laboratory as per 6.3 & 6.4 of IEC 62561-1 2017 protocol, 3 mtr mast all as specified and directed by Engr-in-Charge. Make : TIRUMALA/JEF Cat No JIAT02JIM04 or its equivalent in approved make. 56 Supply & fix 8 mm dia solid Aluminium Conductor for Down Conductor and tested as per IEC 62561- 2 conducted in the Govt. aggregated thirty party laboratory to meet the requirement of IS/ IEC 62305 all as specified and directed by Engr-in-Charge. Make : TIRUMALA/JEF Cat No JIDC01 or its equivalent in approved make. 57 Supply & fix Aluminium conductor holding clamp suitable for fixing 8 mm Down Conductor, Conductor holder @ 1 meter distance should be tested as per IEC-62561-2 conditioning & Ageing test, conducted in the Govt. accredited thirty party laboratory to meet the requirement of IS/ IEC 62305 all as specified and directed by Engr-in-Charge. Make JEF Cat No JIDC01 or approved by E-in-C Branch/CE Southern Command.Make : TIRUMALA/JEF Cat No JICL07 or its equivalent in approved make. 58 Supply & fix Standing Seam clamp to hold 8 mm Al conductor at every 1m dist on the top roof without any drilling on roof, Installation can be made through simple fastening system ,mainly used for seaming sheet roof application tested as per IEC-62561-2 for conditioning & Ageing test & conducted in the Govt. accredited Third party laboratory to meet the requirements of IS/IEC 62305 all as specified and directed by Engr-in-Charge. Make : TIRUMALA/JEF Cat No JICL49 or its equivalent in approved make. 59 Supply & fix Cross splicer should be ttested for conditioning, Ageing Test & Lightning impulse current withstand test: 100 kA of 10/350µs waveform in an accredited Third party laboratory as per 6.3 & 6.4 of IEC 62561-1 2017 protocol all as specified and directed by Engr-in-Charge. Make : TIRUMALA/JEFCat No JISP02 or its equivalent in approved make. 60 Supply & fix Aluminium Straight Splicers for 8mm and 10 mm Conductor to meet the requirement of IS IEC 62305 tested for conditioning, Ageing Test & Lightning impulse current withstand test: 100 kA of 10/350µs waveform in an accredited Third party laboratory as per 6.3 & 6.4 of IEC 62561-1 2017 protocol all as specified and directed by Engr-in-Charge. Make : TIRUMALA/JEF Cat No JISP01 or its equivalent in approved make. 61 Supply & fix Expansion Piece without connector to compensate the expansion and contraction of Solid Round Al. Conductor during temperature variations to be provided on conductors length over 20 meters to connect Solid Round Al. Conductor at both ends to meet the requirements of IS/IEC 62305 all as specified and directed by Engr-in-Charge. Make : TIRUMALA/JEFCat No JISP05 or its equivalent in approved make. 62 Supply & fix test link in order to disconnect the earth termination system for enabling measurements. SS Test Link To connectRound to Flatconductor all as specified and directed by Engr-in-Charge. Make : TIRUMALA/JEF Cat No TL06 or its equivalent in approved make. 63 Supply & fix Earth Electrode Cu Bonded Steel Rod 14.2mm dia x 3000mm-(250Microns);Eco Friendly rust proof heavy duty weather proof Polyethylene Earth Pit Chamber with following dimensions :254 mm dia (top), 330 mm dia (bottom) & 260 mm (height).;14.2 / OD SS Clamp Both Side; Carbon based backfill compound - 25Kg all as specified and directed by Engr-in-Charge. Make : TIRUMALA/JEF Cat No R14.CB1.SS01.E06 or its equivalent in approved make. 64 Suply & fix25 X 6 mm size GI strip from AL Conductor to the earth pit station and further the same strip shall be used for interconnecting all the earth pits below ground leve Zinc coating: 500 g/m square (Approx :70 micron coating) Should be tested and use exclusively for lightning protection ,earthing system and ring equipotential bonding all as specified and directed by Engr-in-ChargeMake : TIRUMALA/JEF Cat No DW16 or its equivalent in approved make. 65 Supply & fix Holder -GI for fixing 25x 6 mm GI Strip complete all as specified and directed by Engr-in-Charge. Make : TIRUMALA/JEFNo JICL08 or its equivalent in approved make. 66 MEDICAL GAS PIPE LINE SYSTEMSupply and installation / fixing, testing and commissioning of Copper pipe : Degreased seamless round coppertube confirming to EN13348:2008 with colour coding for :12mm X 0.7 mm laser Printing on every pipe. Make : Max / Flow/Raj/ janya/ RAJ 67 Supply and installation / fixing, testing and commissioning of Copper pipe : Degreased seamless round coppertube confirming to EN13348:2008 with colour coding for :15mm X 0.9 mm laser Printing on every pipe. Make : Max / Flow/Raj/ janya/ RAJ 68 Supply and installation / fixing, testing and commissioning of Copper pipe : Degreased seamless round coppertube confirming to EN13348:2008 with colour coding for :22x0.9mmlaser Printing on every pipe ) Make : Max / Flow/Raj/ janya/ RAJ 69 Supply and installation / fixing, testing and commissioning of Copper pipe : Degreased seamless round coppertube confirming to EN13348:2008 with colour coding for :28 x0.9mmlaser Printing on every pipe ) Make : Max / Flow/Raj/ janya/ RAJ 70 Supply and fix BS Standard type GEM 10 gasoutlet withprobefor oxygen complete all as specified and as directed. 71 Supply and fix Humidfier bottle forBPC flow meter complete all as specified and as directed. 72 Supply and fix Metal body BPC flow meter (0-15 ltrs ) adult complete all as specified and as directed. 73 Supply and fix BS Standard type GEM 10 gasoutlet withprobefor vacume complete all as specified and as directed. 74 Supply and fix 600 ML VACUUMEJar complete all as specified and as directed. 75 Supply and fix Vacummer regulator complete all as specified and as directed. 76 Supply and fix Zonal valve box completeset withisolationballvalve and gauge (Aluminium framewith MSBox for2services (15mmx 22mm) complete all as specified and as directed. 77 Supply and fix Microprocessor based line pressurealarmdigitaltypefor2 gas serivce(oxygen / vacumm) complete all as specified and as directed. 78 Material and labour for perforated powder coated cable tray of size 25x100x25 mm, thickness 2mm for holding of oxygen gas pipe line all as specified and directed. Make: Daspar / Super Steel Industry / SV metals Pvt Ltd 79 DEMOLITION OF EXISTING BUILDINS (E/M ITEMS)Taking down unserviceble submain wiring any size /any cap complete all as specified and as directed. 80 Taking down unserviceble DBs any size / any cap complete all as specified and as directed. 81 Taking down unservicebleMCB SP/SPN any size /any cap complete all as specified and as directed. 82 Taking up old earthing any size/any type complete all as specified and as directed. 83 Takingdown earth strip/wire any size/any type complete all as specified and as directed. 84 Dismantling and taking out carefully GI pipe 25mmdia including earth work/RCC and complete all as specified and directed Engr -in-Charge.
Contract Date: May 26, 2026 Contract Value : 11.48 Crore
Statutory Bodies & Commissions/Committees No of Bidders 7
10.
Housing Urban and Rular Development #9786076 Price Bid
Tender For Mow/Deposit Work Under Jail-3 Sub Dn, Pwd Bhopal-1 1.2 Transportation by manual labour including loading, unloading and stacking for lead up to 50 metre. 1.2.1 Lime, moorum, building rubbish 1.2.2 Earth 1.2.3 Manure or sludge 1.2.4 Excavated rock 1.2.5 Sand, stone aggregate below 40mm nominal size 1.2.6 Stone aggregate 40mm nominal size and above 1.2.7 Stone soling 1.2.8 Bricks 1.2.9 S.W. Pipes 1.2.9.1 100 mm dia 1.2.9.2 150 mm dia 1.2.9.3 200 mm dia 1.2.9.4 250 mm dia 1.2.9.5 300 mm dia 1.2.9.6 350 mm dia 1.2.9.7 400 mm dia 1.2.9.8 450 mm dia 1.2.9.9 500 mm dia 1.2.9.10 600 mm dia 1.2.10 R.C.C. pipes, Steel cylinder, R.C. pipes, C.I. pipes, and reinforced cement pipes 1.2.10.1 100 mm dia 1.2.10.2 125 mm dia 1.2.10.3 150 mm dia 1.2.10.4 200 mm dia 1.2.10.5 250 mm dia 1.2.10.6 300 mm dia 1.2.10.7 350 mm dia 1.2.10.8 400 mm dia 1.2.10.9 450 and 500 mm dia 1.2.10.10 600, 700, 750 and 800 mm dia 2 1.3 Add extra for every additional lead of 50 metre or part thereof. 1.3.1 Lime, moorum, building rubbish 1.3.2 Earth 1.3.3 Manure or sludge 1.3.4 Excavated rock 1.3.5 Sand, stone aggregate below 40mm nominal size 1.3.6 Stone aggregate 40mm nominal size and above 1.3.7 Stone soling 1.3.8 Bricks 1.3.9 S.W. Pipes 1.3.9.1 100 mm dia 1.3.9.2 150 mm dia 1.3.9.3 200 mm dia 1.3.9.4 250 mm dia 1.3.9.5 300 mm dia 1.3.9.6 350 mm dia 1.3.9.7 400 mm dia 1.3.9.8 450 mm dia 1.3.9.9 500 mm dia 1.3.9.10 600 mm dia 1.3.10 R.C.C. pipes, Steel cylinder, R.C. pipes, C.I. pipes, and unreinforced cement pipes 1.3.10.1 100 mm dia 1.3.10.2 125 mm dia 1.3.10.3 150 mm dia 1.3.10.4 200 mm dia 1.3.10.5 250 mm dia 1.3.10.6 300 mm dia 1.3.10.7 350 mm dia 1.3.10.8 400 mm dia 1.3.10.9 450 and 500 mm dia 1.3.10.10 600, 700, 750 and 800 mm dia 3 2.1 Surface dressing of the ground including removing vegetation and in- equalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m. in all kinds of soil. 2 2.2 Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared. 5 2.3 Clearing grass and removal of the rubbish up to a distance of 50 m outside the periphery of the area cleared. 6 2.4 Felling trees of the girth (measured at a height of 1 m above ground level) including cutting of trunks and branches removing the roots and stacking of serviceable material and disposal of unserviceable material. 2.4.1 beyond 30 cm girth up to and including 60 cm girth 2.4.2 beyond 60 cm girth up to and including 120 cm girth 2.4.3 beyond 120 cm girth up to and including 240 cm girth 2.4.4 above 240 cm girth 7 2.5 Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including disposal of excavated earth up to 50 m lead and lift up to 1.5 m, disposed soil to be levelled and neatly dressed, All kinds of soil 8 2.6 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth. 1.5m in width as well as 10 sqm on plan) including dressing of sides and ramming of bottom disposal of excavated earth, lead up to 50m and lift up to 1.5m, disposed earth to be levelled and neatly dressed. (No extra lift is payable if work is done by mechanical means) All kinds of soil 9 2.7 Earth work in excavation/ by mechanical means (Hydraulic Excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5m in width as well as 10 sqm on plan) including dressing of sides and ramming of bottom disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed. 2.7.1 Ordinary rock 2.7.2 Hard rock (requiring blasting) 2.7.3 Hard rock (blasting prohibited) 10 2.8 Earth work in excavation by mechanical means (Hydraulic Excavator)/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. (No extra lift is payable if work is done by mechanical means)Note:-Excavation of hard rock shall be the property of the contractor subject to recovery. excavated material has to shift from site within 15 days after instruction issued by Engineer-InCharge otherwise after this penalty will imposed on contractor at the rate of Rs 50 per cum per day 2.8.1 Ordinary rock 2.8.2 Hard rock (requiring blasting) 2.8.3 Hard rock (blasting prohibited) 11 2.9 Excavating trenches of required width for pipes, cables, etc. including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m including getting out layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : (No extra lift is payable if work is done by mechanical means) in all kinds of soil 2.9.1 Pipes, cables etc., not exceeding 80 mm dia. 2.9.2 Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia. 2.9.3 Pipes, cables etc. exceeding 300 mm dia but not exceeding 600 mm. 12 2.10 Extra for excavating trenches for pipes, cables etc. in all kinds of soil for depth exceeding 1.5 m, but not exceeding 3 m. (Rate is over corresponding basic item for depth up to 1.5 metre). 13 2.11 Extra for excavating trenches for pipes, cables, etc., in all kinds of soil for depth exceeding 3 m in depth, but not exceeding 4.5 m. (Rate is over corresponding basic item for depth up to 1.5 metre.) 14 2.12 Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, depth up to 1.5 m including including consolidating each deposited layers by ramming, watering etc. stacking serviceable material for measurements and disposal of unserviceable material as directed, within a lead of 50m : 2.12.1 Ordinary rock : 2.12.1.1 Pipes, cables etc. not exceeding 80 mm dia. 2.12.1.2 Pipes, cables etc. exceeding 80 mm dia but not exceeding 300 mm dia. 2.12.1.3 Pipes, cables exceeding 300 mm dia but not exceeding 600mm dia 2.12.2 Hard rock (requiring blasting) 2.12.2.1 Pipes, cables etc. not exceeding 80 mm dia. 2.12.2.2 Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia. 2.12.2.3 Pipes, cables etc. exceeding 300 mm dia but not exceeding 600mm dia 2.12.3 Hard rock (blasting prohibited) 2.12.3.1 Pipes, cables etc. not exceeding 80 mm dia. 2.12.3.2 Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia. 2.12.3.3 Pipes, cables etc. exceeding 300 mm dia but not exceeding 600mm dia. 15 2.13 Extra for excavating trenches for pipes, cables, etc. in ordinary/hard rock exceeding 1.5 m in depth but not exceeding 3 m. (Rate is over corresponding basic item for depth up to 1.5 metre.) 16 2.14 Extra for excavating trenches for pipes, cables, etc. in ordinary/hard rock exceeding 3m in depth but not exceeding 4.5 m. (Rate is over corresponding basic item for depth up to 1.5 metre.) 17 2.15 Close timbering in trenches including strutting, shoring and packing cavities (wherever required) complete. (Measurements to be taken of the face area timbered). 2.15.1 Depth not exceeding 1.5 m. 2.15.2 Depth exceeding 1.5 m but not exceeding 3 m. 2.15.3 Depth exceeding 3 m but not exceeding 4.5 m. 18 2.16 Close timbering in case of shafts, wells, cesspits, manholes and the like including strutting, shoring and packing cavities (wherever required) etc. complete. (Measurements to be taken of the face area timbered). 2.16.1 Depth not exceeding 1.5 m. 2.16.2 Depth exceeding 1.5 m but not exceeding 3 m. 2.16.3 Depth exceeding 3 m but not exceeding 4.5 m. 19 2.17 Close timbering over areas including strutting, shoring and packing, cavities (wherever required) etc. complete. (Measurements to be taken of the face area timbered) : 2.17.1 Depth not exceeding 1.5 m. 2.17.2 Depth exceeding 1.5 m but not exceeding 3 m. 2.17.3 Depth exceeding 3 m but not exceeding 4.5 m. 20 2.18 Extra for planking, strutting and packing materials for cavities (in close timbering) if required to be leftpermanently in position. (Face area of timber permanently left to be measured). 21 2.23 Extra rates for quantities of works, executed: 2.23.1 In or under water and/or liquid mud, including pumping out water as required. 2.23.2 In or under foul position, including pumping out water as required. Note: - The extra percentage rate is applicable in respect of each item but limited to quantity executed in difficult conditions. The depth shall be reckoned correct to 0.1 metre. 0.05 metre or more shall be taken as 0.1 metre and less than 0.05 metre ignored. 22 2.24 Filling available excavated earth (excluding hard rock/Ordinary rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. 23 2.25 Extra for every additional lift of 1.5 m or part thereof in excavation. (No extra lift is payable if work is done by mechanical means) 2.25.1 All kinds of soil. 2.25.2 Ordinary or hard rock. 24 2.26 Supplying and filling in plinth with crusher stone dust / coarse sand under floors including, watering, ramming and compacting in layers not exceeding 20cm in depth and dressing complete Note: - Maximum thickness of this layer shall be 20 cm. 25 2.27 Supplying and filling in plinth under floors including watering ramming consolidating in layers not exceeding 20cm in depth and dressing complete. 2.27.1 With hard muram having CBR >12 % at under floors including watering, ramming and compacting (minimum compaction 95% of MDD) in layers not exceeding 20cm in thickness and dressing complete. (Note:- maximum thickness of this layer to be provided shall be 30cm) 2.27.2 Supplying and filing in plinth with soil (other then BC soil ) having MDD not less than 1.85 t/m3 under floors including watering, ramming and compacting (minimum compaction 95% of MDD) in layers not exceeding 15cm depth and dressing complete. 26 2.28 Excavating holes more than 0.10 cum & upto 0.5 cum including getting out the excavated soil, then refiling the soil as required in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering etc., disposing of surplus excavated soil; as directed within a lead of 50 m and lift upto 1.5m. 2.28.1 All kinds of soil. 2.28.2 Ordinary rock 2.28.3 Hard rock (requiring blasting) 2.28.4 Hard rock (blasting prohibited) 27 2.29 Supplying chemical emulsion in sealed containers including delivery as specified. (Chlorpyriphos/ Lindane emulsifiable concentrate of 20%) 28 2.30 Diluting and injecting chemical emulsion for POST- CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : 2.30.1 Along external wall where the apron is not provided using chemical emulsion @ 7.5 liters / sqm of the vertical surface of the substructure to a depth of 300 mm including excavation channel along the wall and rodding etc. complete, with Chlorpyriphos/ Lindane E.C. 20% with 1% concentration. 2.30.2 Along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc. With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration. 2.30.3 Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diametre holes and plugging with cement mortar 1 :2 (1 cement : 2 sand) to match the existing floor, With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration. 2.30.4 Treatment of existing masonry using chemical emulsion @ one litre per hole at 300 mm interval including drilling 10mm dia and 200mm deep holes at 45 degree and plugging them with cement mortar 1:2 (1 cement : 2 sand) to the full depth of the hole, with Chlorpyriphos/ Lindane E.C. 20% with 1% concentration. 2.30.5 Treatment at points of contact of wood work by chemical emulsion Chlorpyriphos/ Lindane (in oil or kerosene based solution) @ 0.5 litres per hole by drilling 6 mm dia holes at downward angle of 45 degree at 150 mm centre to centre and sealing the same. 29 2.31 Deduct for disposed soil not levelled and neatly dressed. 30 2.32 Preconstruction antitermite treatment to the building under construction by providing.Stage 1: Treatment should not be carried out when it is raining or when soil is wet with rain or subsoil water. This also applies to fill up soil within the plinth area before laying the subgrade for flooring. 31 2.33 Making bore holes for providing dowel bars at designed depth in rock foundation by drilling 40 mm dia bore hole in rock including necessary bending hooking, in position and grouting with cement slurry etc. complete as per drawing and specification. (Steel to be paid separately). 32 2.34 Excavation in soil using hydraulic excavator and including cutting and loading in tippers, trimming bottom and side slopes in accordance with requirements of lines, grades and cross- section, and transporting to the appropriate ground contour, location and levelling and dressing earth neatly with all lifts and lead upto 1000 metre. 33 2.35 Earth work in rough excavation by any means and bankingfilling excavated earth in layers not exceeding 20cm in depth, breaking clods, watering rolling each layer with 1/2 tonne in embankments for roads, flood banks, marginal bank and guide bank of filling up ground depression within campus, lead upto 50m and all lift. All kinds of soil. 34 2.36 Bankingfilling excavated earth in layers not exceeding 20cm in depth, breaking clods, watering rolling each layer with 1/2 tonne roller or wooden or steel rammers etc. and rolling every 3rd and top-must layer with power roller of minimum 8 tonnes and dressing up, in embankments for roads, flood banks, marginal bank and guide bank etc. lead upto 50m and lift upto 1.5m. All kinds of soil. 35 2.37 Deduct for not rolling with power roller of minimum 8 tonnes for bankingfilling excavated earth in layers not exceeding 20cm in depth. 36 2.38 Deduct for not watering with the excavated earth for bankingfilling 37 2.39 Providing and laying of permanent piping technology anti-termite treatment before flooring work by installing LLDP (Low linear density polyethylene) tube of 8 mm O.D. & 6.4 mm I.D.with inbuilt pressure compensation chip at every 30 cm interval in the tube,. The contractor shall submit approved line plan for piping system and junction boxes dully approved by Engineer-in- charge with bond of 5 year warranty. 2.39.1 Permanent piping system with Junction boxes 2.39.2 Anti-termite chemical injected area 38 2.40 Ploughing the existing ground to a depth of 15 cm to 25 cm and watering the same. (All kinds of soil) 39 3.1 Cement mortar 1:1 (1 cement: 1 sand) 40 3.2 Cement mortar 1:2 (1 cement: 2 sand). 41 3.3 Cement mortar 1:3 (1 cement: 3 sand). 42 3.4 Cement mortar 1:4 (1 cement: 4 sand). 43 3.5 Cement mortar 1:5 (1 cement: 5 sand). 44 3.6 Cement mortar 1:6 (1 cement: 6 sand). 45 3.7 Cement mortar 1:2 (1 cement: 2 stone dust). 46 3.8 Cement mortar 1:2 (1 cement: 2 marble dust). 47 3.9 White cement mortar 1:2 (1 white cement: 2 marble dust). 48 3.10 Cement mortar 1:5 (1 cement: 5 marble dust). 49 3.11 White cement mortar 1:3 (1 white cement: 3 marble dust). 50 3.12 White cement mortar 1:5 (1 white cement: 5 marble dust). 51 3.13 Mortar in lime , surkhi (50% red and 50% light yellow) and marble dust 1:1.5:0.5 52 4.1 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work upto plinth level : 4.1.1 With 20mm nominal size graded stone aggregate. 4.1.1.1 M-25 – Grade concrete 4.1.1.2 M-20 – Grade concrete 4.1.1.3 M-15 – Grade concrete 4.1.1.4 M-10Nominal (Mix-1 Cement : 3 sand : 6 graded stone aggregate ) 4.1.2 With 40mm nominal size graded stone aggregate. 4.1.2.1 M-15 - Grade concrete 4.1.2.2 M-10 Nominal (Mix -1 Cement : 3 sand : 6 graded stone aggregate) 4.1.2.3 M-7.5 Nominal Mix -1 Cement : 4 sand : 8 graded stone aggregate 4.1.3 With fly ash. 4.1.3.1 1:2:3½:9 (1 ordinary Portland cement : 2 Fly ash : 3½ sand: 9 graded stone aggregate 40 mm nominal size) 4.1.3.2 1:2½:4:11 (1 ordinary Portland cement : 2½ fly ash : 4 sand : 11 graded stone aggregate 40 mm nominal size) Note: No fly ash is to be added to Portland Pozzolona cement in any case which itself contains fly ash. 53 4.2 Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets etc. upto floor two level, excluding the cost of centering, shuttering and finishing : 4.2.1 With 20mm nominal size graded stone aggregate 4.2.1.1 M-25 – Grade concrete 4.2.1.2 M 20 – Grade concrete 4.2.1.3 M 15 – Grade concrete 4.2.1.4 M-10 Nominal Mix -1 Cement : 3 sand : 6 graded stone aggregate 4.2.2 With 40mm nominal size graded stone aggregate 4.2.2.1 M-15 - Grade concrete 4.2.2.2 M-10 Nominal Mix -1 Cement : 3 sand : 6 graded stone aggregate 54 4.3 Centering and shuttering including strutting, propping etc. and removal of form work for : 4.3.1 Upto plinth: Foundations, footings, bases for columns, plinth beams, curtain walls, columns below plinth. 4.3.2 above plinth: Retaining walls, return walls, walls (any thickness) including attached pilasters, buttresses, and string courses fillets etc. 4.3.3 Above plinth: Columns, pillars, posts and struts. 55 4.4 Providing and laying cement concrete in kerbs, steps and the like at or near ground level excluding the cost of centering, shuttering and finishing . 4.4.1 M-15 (With 20mm nominal size graded stone aggregate) 4.4.2 M-10 (With 20mm nominal size graded stone aggregate) Nominal Mix -1 Cement : 3 sand : 6 graded stone aggregate 56 4.5 Providing and fixing at or near ground level precast cement concrete in kerbs, edgings etc. as per approved pattern and setting in position with cement morta1:3 (1 cement : 3 sand) on exposed surfaces complete.(With 20mm nominal size graded stone aggregate) 57 4.6 Providing and fixing upto floor two level precast cement concrete string or lacing courses, copings, bed plates, anchor blocks, plain window sills, shelves, louvers, steps, stair cases, etc. including cost of required centering, shuttering and finishing smooth with 6mm thick cement plaster 1:3 (1 Cement : 3 sand) on exposed surfaces complete. 4.6.1 M-25 (With 20mm nominal size graded stone aggregate) 4.6.2 M-20 (With 20mm nominal size graded stone aggregate) 4.6.3 M-15 (With 20mm nominal size graded stone aggregate) 4.6.4 M-10 (With 20mm nominal size graded stone aggregate) Nominal Mix -1 Cement: 3 sand: 6 graded stone aggregate. 58 4.7 Providing and fixing upto floor two level precast cement concrete solid block including hoisting and setting in position with 6mm thick cement plaster 1:3 (1 cement : 3 sand) on exposed surfaces complete : 4.7.1 M-15 (With 20mm nominal size graded stone aggregate) 4.7.2 M-10 (M 10) (With 20mm nominal size graded stone aggregate) Nominal Mix -1 Cement : 3 sand : 6 graded stone aggregate 59 4.8 Providing and Fixing upto floor two level pre cast concrete hollow block including hoisting and setting in position with cement mortar 1:3 (1 cement : 3 sand), cost of required centering, shuttering and finishing smooth with 6mm thick cement plaster 1:3 (1 cement : 3 sand) on exposed surfaces complete. 4.8.1 M-15 (With 20mm nominal size graded stone aggregate) 4.8.2 M-10 (With 20mm nominal size graded stone aggregate) Nominal Mix -1 Cement: 3 sand: 6 graded stone aggregate. 60 4.9 Add extra for item no. 4.6, 4.7 and 4.8 above floor two level for every additional floor or part there of 61 4.10 Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement: 2 sand: 4 graded stone aggregate 12.5mm nominal size). 62 4.11 Providing and laying damp-proof course 50mm thick with cement concrete 1:2:4 (1 cement : 2 sand : 4 graded stone aggregate 20mm nominal size). 63 4.12 Extra for providing and mixing water proofing material as per IS standard in cement concrete work quantity as prescribed by the manufacturer. 64 4.13 Applying a coat of residual petroleum bitumen of penetration 80/100 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil. 65 4.14 Extra for concrete work in superstructure above floor two level for each floors or part thereof 66 4.15 Extra for laying concrete in or under water and/or liquid mud including cost of pumping or bailing out water and removing slush etc. complete.Note for item No. 4.15:- The quantity will be calculated by multiplying. The depth of centre of gravity shall be reckoned correct to 0.1m. 0.05m or more shall be taken as 0.1m and less than 0.05m ignored. 67 4.16 Extra for laying concrete in or under foul positions. 68 4.17 Making plinth protection 50mm thick of cement concrete grade M10 over 75mm bed of dry metal ballast 40mm nominal size well rammed and consolidated and filled with sand including finishing the top smooth (with 20mm nominal size graded stone aggregate.) 69 4.18 Extra for addition of synthetic polyester triangular fiber of length 12 mm, effective diameter 10-40 microns and specific gravity of 1.34 to 1.40 in cement concrete/RCC/Flooring/ Water retaining structures by using 125 gms of synthetic polyester triangular fibre for 50 kgs cement used as per directions of Engineer-in- Charge. 70 4.19 Precasting and placing in position 125 mm dia Bollards 600 mm high of required shape including providing M.S. Pipe welded at bottom and embedded 150mm in cement concrete 1:3:6 (1 Cement : 3 sand : 6 graded stone aggregate 20 mm nominal size) including necessary excavation of size 250x250x450mm deep for the same in bitumen/concrete pavement at specified spacing. 71 4.20 Providing and fixing up to floor two level precast cement concrete string or lacing courses, copings, bed plates, anchor blocks, and setting in position with cement mortar 1:3 (1 Cement : 3 coarse sand), cost of required Centering complete. 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20mm nominal size) 72 4.21 Providing and fixing up to floor two level precast cement concrete solid block, including hoisting and setting in position with cement mortar 1:3 (1 cement : 3 coarse sand), cost of required centering, shuttering complete . 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20mm nominal size) 73 4.22 Providing and fixing up to floor two level precast cement concrete hollow block, including hoisting and setting in position with cement mortar 1:3 (1 cement : 3 coarse sand), cost of required centering, shuttering complete. 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20mm nominal size) 74 4.23 Providing and laying in position ready mixed plain cement concrete, using fly ash and cement content as per approved design curing, admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer-in-charge.Note : (1) Fly ash conforming to grade I of IS 3812 (Part-1) only be used as part replacemen to be ensured in accordance with clauses 5.2 and 5.2.1 of IS: 456 -2000 in the items of BMC and RMC. 4.23.1 All works up to plinth level: 4.23.1.1 M-20 grade plain cement concrete (cement content considered @ 280 kg/cum) 4.23.1.2 M-15 grade plain cement concrete (cement content considered @ 240 kg/cum) 4.23.1.3 M-10 grade plain cement concrete (cement content considered @ 220 kg/cum) 4.23.2 All works above plinth and upto floor two level 4.23.2.1 M-20 grade plain cement concrete (cement content considered @ 280 kg/cum) 4.23.2.2 M-15 grade plain cement concrete (cement content considered @ 240 kg/cum) 4.23.2.3 M-10 grade plain cement concrete (cement content considered @ 220 kg/cum) 75 4.24 Providing and laying in position ready mixed plain cement concrete, with cement content as per approved design mix and manufactured in fully automatic batching plant and transported to site of work cost of centering, shuttering and finishing, including cost of curing, admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer-in- charge. 4.24.1 All works up to plinth level: 4.24.1.1 M-20 grade plain cement concrete (cement content considered @ 280 kg/cum) 4.24.1.2 M-15 grade plain cement concrete (cement content considered @ 240 kg/cum) 4.24.1.3 M-10 grade plain cement concrete (cement content considered @ 220 kg/cum) 4.24.2 All works above plinth and upto floor two level 4.24.2.1 M-20 grade plain cement concrete (cement content considered @ 280 kg/cum) 4.24.2.2 M-15 grade plain cement concrete (cement content considered @ 240 kg/cum) 4.24.2.3 M-10 grade plain cement concrete (cement content considered @ 220 kg/cum) 76 4.25 Plum Cement concrete 1:2:4 with 75% graded metal of maximum size 40 mm and 25% plum of 150mm size. 77 4.26 Providing and laying cement concrete in Sunken floors of WC, Toilet, Wash Area, etc with 1:5:10 (1 cement : 5 coarse sand (zone-3) : 10 graded stone aggregate 40 mm nominal size) excluding the cost of centering and shuttering 78 5.1 Providing and laying in position specified grade of reinforced cement concrete (with 20mm nominal size graded stone aggregate) excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 5.1.1 M-20 Grade Concrete 5.1.2 M-15 Grade Concrete 79 5.2 Reinforced cement concrete work (with 20 mm nominal size graded stone aggregate) in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, posts and struts etc. above plinth level and upto floor two level excluding cost of centering, shuttering, finishing and reinforcement: 5.2.1 M-20 Grade Concrete 80 5.3 Reinforced cement concrete work (with 20 mm nominal size graded stone aggregate) in beams, suspended floors, roofs having slope of any degree landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral staircases above plinth level and upto floor two level excluding the cost of centering, shuttering, finishing and reinforcement in concrete grade. 5.3.1 M-20 Grade Concrete 81 5.4 Providing and laying upto floor two level reinforced cement concrete (with20 mm nominal size graded stone aggregate) in kerbs, steps and the like excluding the cost of centering, shuttering, finishing and reinforcement with Concrete grade. 5.4.1 M-20 Grade Concrete 82 5.5 Reinforced cement concrete work (with 20 mm nominal size graded stone aggregate) in arches, archribs, domes, vaults, shells, folded plate above plinth level and upto floor two level excluding the cost of centering, shuttering, finishing and reinforcement in Concrete grade. 5.5.1 M-20 Grade Concrete 83 5.6 Reinforced cement concrete work (with 20 mm nominal size graded stone aggregate) in chimneys, shafts, upto floor two level excluding the cost of centring, shuttering, finishing and reinforcement with 5.6.1 M-20 Grade Concrete 88 5.7 Reinforced cement concrete work (with 20 mm nominal size graded stone aggregate) in well-steining excluding the cost of centering, shuttering, finishing and reinforcement with 5.7.1 M-20 Grade Concrete 84 5.8 Reinforced cement concrete work (with 20 mm nominal size graded stone aggregate) in vertical and horizontal fins individually or forming box louvers, facias and eaves boards up to floor two level excluding the cost of centering, shuttering, finishing and reinforcement in M 20 –Grade Concrete 85 5.9 Centering and shuttering in cluding strutting, propping etc. and removal of form for: 5.9.1 Foundations, footings, bases of columns, etc. for concrete upto plinth level 5.9.2 Walls (any thickness) in cluding attached pilasters butter esses, plinth beams and string courses etc. 5.9.2.1 Uptoplinthlevel. 5.9.2.2 Above plinth upto 3.6 m height from plinth level 5.9.2.3 Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc. including cost of de-shuttering and decentering at all levels, over a height of 3.6 m, for every additional height of 1 metre or part thereof. 5.9.3 Suspended floors, roofs, landings, balconies and access platform. 5.9.4 Shelves(Cast in situ) 5.9.5 Lintels, beams, girders, bressumers and cantilevers 5.9.6 Columns, P i l l a r s , Piers, Abutments, Posts and Struts. 5.9.7 Stairs, (excluding landings) except spiral- Staircases. 5.9.8 Spiral staircases (including landing). 5.9.9 Arches, domes,vaults upto 6m span 5.9.10 Extra for arches, domes, vaults exceeding 6 m span 5.9.11 Chimneys and shafts 5.9.12 Coffer/waffle slab of any size or shape as shown in the drawing. 5.9.13 Well steining 5.9.14 Vertical and horizontal fins individually or forming Box louvers band, facias and eaves boards. 5.9.15 Extra for shuttering in circular work or any other geometrical shape (20% of respective centering and shuttering items). 5.9.16 Small lintels not exceeding 1.5m clear span, mouldingas incornices, window, sills, courses, bands, copings, bed plates, anchor blocks and the like. 5.9.17 Cornices and mouldings 5.9.18 Small surfaces such as cantilever ends, brackets and ends of steps, caps and bases to pilasters and columns and the like. 5.9.19 Weather shade, Chajjas, corbels etc., including Edges. 5.9.20 Suspended floors, roofs, landings, balconies and Access platform. With water proof ply 12 mm thick. (item to be executed with prior permission of S.E. in case of B & R works and from Additional Project Director in case of PIU works) 5.9.21 Lintels, beams, columns, girders, bressumers and cantilevers with waterproof ply 12 mm thick (item to be executed with prior permission of S.E. in case of B&R works and from Additional Project Director in case of PIU works) 86 5.10 Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc. including cost of de-shuttering and decentering at all levels, over a height of 3.6 m, for every additional height of 1 metre or part thereof (Plan area to be measured) 5.10.1 Suspended floors, roofs, landing, beams and balconies (Plan area to be measured). 87 5.11 Providing, hoisting and fixing up to floor two level precast reinforced cement concrete in lintels, manhole cover, shelves and like including setting in cement mortar 1:3 (1 cement : 3 sand), cost of required centering, shuttering and finishing with neat cement punning on exposed surfaces but excluding the cost of reinforcement with M 15 –Grade Concrete. 88 5.12 Providing precast cement concrete Jali 1:2:4 (1 cement : 2 sand : 4 graded stone aggregate 6mm nominal size) reinforced with 1.6 mm dia mild steel wire including centering and shuttering, roughening cleaning, fixing and finishing in cement mortar 1:3 (1 cement: 3 sand) etc. complete excluding plastering of the jambs, sills and soffits. 5.12.1 50 mm thick 5.12.2 40 mm thick 5.12.3 25 mm thick 89 5.13 Encasing rolled steel sections, in beams and columns, with cement concrete M 15 (1 cement: 2 sand: 4 graded stone aggregate 20mm nominal size) including centering and shuttering complete but excluding cost of reinforcement. 80 5.14 Encasing rolled steel section in grillages with cement concrete M 15 (1 cement: 2 sand: 4 graded stone aggregate 20 mm nominal size) including centering and shuttering but excluding cost of expanded metal and hangers. 91 5.15 Extra for providing and fixing expanded metal mesh of size 20x60mm and strands 3.25mm wide 1.6mm thick weighing 3.64 kg per sqm for encasing of rolled steel sections in beams, columns and grillages excluding cost of hangers. 92 5.16 Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding including cost of binding wire all wastages and overlaps, couplers (overlaps shall be provided as per requirement of IS 13920 for ductile detaling IS 456 RCC Design & SP 34 Reinforcement detailing ) etc. complete .(Note:-1. Spacer bars (chairs) shall be paid separately as shown in the drawing and as per direction of engineer in charge.2. No extra payment shall be done for overlaps and/or couplers.3.Couplers shall be conforming to IS code on “Reinforcement Couplers for Mechanical Splices of Bars for Concrete Reinforcement - Specification”) 5.16.1 Mild steel and Medium Tensile steel bars. 5.16.2 Hard drawn steel wire 5.16.3 Cold twisted bars (CTD) 5.16.4 Hot rolled deformed bars 5.16.5 Hard drawn steel wire fabric 5.16.6 Thermo-Mechanically Treated bars. (TMT/TMX) FE 500 or more conforming to IS 1786 93 5.17 Add extra for providing reinforcement above Floor two level for every additional floor or part thereof. 94 5.18 Providing and fixing in position copper plate as per design for expansion joints. 95 5.19 Providing and filling in position, blown bitumen in expansion joints. 96 5.20 Providing and filling in position bitumen mix filler of Proportion 80 kg. Of hot bitumen, 1 kg. Of cement and 0.25 cubic metre of sand for expansion joints. 97 5.21 Providing and filling gap in expansion joint between RCC/ Stone/Ceramic tiles/Granite/ Marble by providing silicon sealant over backer rod of approved quality weather sealant as per drawing and direction of engineer in charge up to 25mm width & 12 mm depth. 98 5.22 Providing and fixing in position bitumen impregnated fibre board conforming to IS: 1838 including cost of primer, sealing compound in expansion joints. 5. 22.1 12 mm thick 5. 22.2 25 mm thick 5. 22.3 50 mm thick 99 5.23 Providing and fixing sheet covering over expansion joints with iron screws as per design. 5. 23.1 Non-asbestos fibre cement board 6 mm thick as per IS: 14862. 5. 23.1.1 150mm wide. 5. 23.1.2 200mm wide. 5. 23.1.3 250mm wide. 5. 23.2 Aluminium fluted strips 3.15mm thick. 5. 23.2.1 150 mm wide. 5. 23.2.2 200 mm wide. 5. 23.2.3 250 mm wide. 5. 23.3 Stainless steel Grade 304 plate-1.0 mm thick 5. 23.3.1 150 mm wide. 5. 23.3.2 200 mm wide. 5. 23.3.3 250 mm wide. 100 5.24 Providing for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections. 101 5.25 Extra for laying reinforced cement concrete in or under water and/ or liquid mud including cost of pumping or bailing out water and removing slush etc., complete.Note- For Item No. 5.25:-The quantity will be calculated by multiplying the depth measured from the subsoil water level up to the centre of gravity The depth of centre of gravity shall be reckoned correct to 0.1 m. 0.05 m or more shall be taken as 0.1 m and less than 0.05 m ignored. No extra payment shall be made for placing reinforcement or centering & shuttering under sub – soil water condition 102 5.26 Extra for laying reinforced cement concrete in or under foul positions. 103 5.27 Providing and laying in position machine batched, machine mixed cement concrete (BMC) of M-25 grade for reinforced cement concrete work using cement content as per approved mix design concrete without impairing strength and durability as per direction of Engineer-in charge and pumping of concrete to site of laying and finishing but excluding the cost of centering, shuttering, and reinforcement. (Note: - Minimum cement content is 330 kg/cum) and no extra payment for extra cement used as per mix design. 5.27.1 All works upto plinth level. 5.27.2 All works above plinth level and upto floor five level. 5.27.3 Add extra for each floor for all works above floor five level. 104 5.28 Extra for providing richer mixes of BMC design mix as per item no 5.27 upto plinth level and at all floor levels. (No extra payment for using extra cement as per requirement of mix design.) 5. 28.1 Providing M-25 grade concrete instead of M- 20 grade.(Note : minimum cement content is @ 330 kg/cum) 5. 28.2 Providing M-30 grade concrete instead of M- 25 grade.(Note : minimum cement content is @ 340 kg/cum) 5. 28.3 Providing M-35 grade concrete instead of M- 25 grade.(Note: : minimum cement content is @ 350 kg/cum) 5. 28.4 Providing M-40 grade concrete instead of M- 25 grade.(Note: minimum cement content is @ 360 kg/cum) 105 5.29 Providing and placing in position precast reinforced cement concrete waffle units square or rectangular as per design and shape for floors and roofs in M-20 –Grade Concrete (with graded stone aggregate 10mm nominal size. including provision of steel hooks for lifting and form work, handling, hoisting, centering and erection complete for all floor levels but excluding the cost of reinforcement. 106 5.30 Providing and laying in position ready mixed concrete (RMC) of M-25 grade for reinforced cement concrete work, using cement content as per approved design mix and manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of concrete, improve workability without impairing strength and durability as per direction of the Engineer - in - charge.Note: Minimum cement content is @ 330 kg/cum. (No extra payment for using extra cement as per requirement of mix design.) 5.30.1 All works upto plinth level. 5.30.2 All works above plinth level and upto floor V level. 5.30.3 Extra for each additional floor for all works above floor five level 107 5.31 Extra for R.C.C. work above floor two level for each floors or part thereof. (except items 5.27 and 5.30) 108 5.32 Supplying and applying pre tested and approved water based concrete curing compound to concrete/ masonry surface, all as per manufacturer’s specification and direction of Engineer-in-charge. 5.32.1 Non pigmented wet curing compound 5.32.2 Pigmented wet curing compound. 109 5.33 Providing and fixing in position factory made precast RCC M-40 doors, windows and ventilator frames having excellent smooth finish, as per IS: 6523 with 6mm dia main reinforcement each polymer block having at least four holes for passing one or adjacent rebates to hold fast grill or steel bar, ventilator frame provided with grooves for louvers at an angel of 45 degree at spacing to block direct vision etc. complete, as per the direction of Engineer-in-charge. The cost of hold fast and cement concrete block of 1:3: 6 (1 Cement: 3 sand: 6 Graded stone aggregate 20mm nominal size) mix is also included in the item. 5. 33.1. Frame 125 mmx 60 mm (double rebate) 5. 33.2. Frame 100mmx 60 mm (Single rebate) 5. 33.3 Frame 85mmx 60 mm (Single rebate) 110 5.34 Smooth finishing of the exposed surface of RCC work with 6mm thick cement mortar 1:3 (1 cement: 3 sand). 111 5.35 Providing and fixing in position pre moulded compressible filler board made from polymer base in black color approved make conforming to the specifications having minimum density of 95 kg / cum, non- staining, with less than 1 percent water absorption and compression recovery of 93 percent minimum including cost of double sided adhesive tape, sealant etc. in expansion joints. 5. 35.1 12 mm thick 5. 35.2 25 mm thick. 5. 35.3 50 mm thick. 112 5.36 Providing and sealing the retaining wall expansion Joints with anodized aluminum extruded section of 135 mm × 3.1 mm confirm to alloy of 6063 T5/T6including fixing of an imported EPDM moisture Barrier conform to (American Society for Testing and Materials) 2240 & ASTM - G53 & 84 fixing with Epoxy adhesive confirm to ASTM C-881 complete in all respect as per manufacturer Drawing and specifications. With 5 year guarantee. 113 5.37 Providing and fixing sheet covering over expansion joints with iron screws as per design. Non- asbestos cement bonded particle board 6 mm thick as IS: 14276 5.37.1 150mm wide 5.37.2 200mm wide 5.37.3 250mm wide 114 5.38 Providing & laying in position Prestressing steel strands (low relaxation) on hollow core bed by using mechanical pulling arrangement like Rabbit/ Bed master including all accessories for Stressing &destressing operations as per approved make conforming to IS1343 & grade FY-1860 etc, complete as per drawings and direction of Engineer -in- charge. 115 5.39 Providing and fixing of expansion joint system related with floor location as per drawings and direction of Engineer-In- Charge. The joints system will be of extruded aluminum base members, self aligning / self centering arrangement and support plates etc. Provision of Moisture Barrier Membrane in the Joint System to have watertight joint is mandatory requirement all as per the manufactures design and as approved by Engineer - inCharge. (Material shall confirm to ASTM 6063). 5. 39.1 Floor Joint of 100 mm gap 5. 39.2 Floor Joint of 150 mm gap 5. 39.3 Floor Joint of 200 mm gap 116 5.40 Providing and fixing of expansion joint system related with wall joint (internal/ external) location as per drawings and direction of Engineer-In- Charge. The joints shall be of extruded aluminum base members, self aligning / centering amongst the components of the Joint System. The Joint System shall utilize light weight aluminum profiles exhibiting minimal exposed aluminum surfaces mechanically snap locking the multicellular to facilitate movement. (Material shall confirm to ASTM 6063). 5. 40.1 Wall Joint of 100 mm gap 5. 40.2 Wall Joint of 150 mm gap 5. 40.3 Wall Joint of 200 mm gap 117 5.41 Providing and fixing of expansion joint system of approved make and manufactures for various roof locations as per approved drawings and direction of Engineer-In- Charge. The joints shall be of extruded aluminum base members with, self aligning and self centeringarragement support plates asper ASTM B221-02. . The Joint System shall resists damage or deterioration from the impact of falling ice, exposure to UV, airborne contaminants and occasional foot traffic from maintenance personnel. Provision of Moisture Barrier Membrane in the Joint System to have water tight joint is mandatory requirement. (Material shall confirm to ASTM 6063.) 5.41.1 Roof Joint for 100 mm gap 5.41.2 Roof Joint for 150 mm gap 5.41.3 Roof Joint for 200 mm gap 118 5.42 Providing and fixing Scaffolding net of required width made of high density Polyethylene UV stabilized knitted on warp knitting machines having density 100gm/sqm and shading coefficient minimum 75% around the construction site/ for vertical extension as per requirement including fastening/tying with building/scaffolding pipes or with any other fixtures etc. complete as per direction of Engineer-in-Charge. (One time payment shall be made for providing Scaffolding net from start of work till completion of work including shifting if any. The Scaffolding net shall be the property of the contractor on completion of the work) 119 6.1 Brick work with well burnt chimney bricks in bulls pattern trench kiln manufactured by ghol process, crushing strength not less than 40kg /cm2 and water absorption not more than 15% in foundation and plinth i/c curing etc. complete. 6.1.1 Cement mortar 1:4 (1 cement : 4 sand) 6.1.2 Cement mortar 1:6 (1 cement : 6 sand) 120 6.2 Brick work with well burnt chimney bricks in bulls patent trench kiln manufactured by ghol process ,crushing strength not less than 40kg /cm2 and water absorption not more than 15% in superstructure above plinth level and up to floor two level i/c curing etc. complete. 6.2.1 Cement mortar 1:4 (1 cement : 4 sand) 6.2.2 Cement mortar 1:6 (1 cement : 6 sand) 121 6.3 Brick work with well burnt chimney bricks in bulls pattern trench kiln, crushing strength not less than 25kg /cm2 and water absorption not more than 20% in foundation and plinth i/c curing etc complete. 6.3.1 Cement mortar 1:4 (1 cement : 4 sand) 6.3.2 Cement Mortar 1:6 (1 cement:6 sand). 122 6.4 Brick work with well burnt chimney bricks in bulls pattern trench kiln, crushing strength not less than 25kg /cm2 and water absorption not more than 20% in superstructure above plinth level and up to floor two level i/c curing etc complete. 6.4.1 Cement mortar 1:4 (1 cement : 4 sand) 6.4.2 Cement Mortar 1:6 (1 cement:6 sand). 123 6.5 Brick work with well brunt open bhatta, bricks, crushing strength not less than 25kg /cm2 and water absorption not more than 20% in foundation and plinth i/c curing etc complete. 6.5.1 Cement mortar 1:4 (1 cement : 4 sand) 6.5.2 Cement Mortar 1:6 (1 cement: 6 sand). 124 6.6 Brick work with well brunt open bhatta, bricks, crushing strength not less than 25kg / cm2 and water absorption not more than 20% in superstructure above plinth level and up to floor two level i/c curing etc complete. 6.6.1 Cement mortar 1:4 (1 cement : 4 sand) 6.6.2 Cement Mortar 1:6 (1 cement : 6 sand) 125 6.7 Brick work with fly ash lime bricks (FALG Bricks) conforming to IS:12894-2002, in super structure above plinth level up to floor two level in : 6.7.1 Having 100 kg / cm2 average compressive strength. 6.7.1.1 Cement mortar 1:4 (1 cement : 4 sand) 6.7.1.2 Cement mortar 1:6 (1 cement : 6 sand) 6.7.2 Having 75 kg / cm2 average compressive strength. 6.7.2.1 Cement mortar 1:4 (1 cement : 4 sand) 6.7.2.2 Cement mortar 1:6 (1 cement : 6 sand) 6.7.3 Having 50 kg / cm2 average compressive strength. 6.7.3.1 Cement mortar 1:4 (1 cement : 4 sand) 6.7.3.2 Cement mortar 1:6 (1 cement : 6 sand) 126 6.8 Brick work with calcium silicate bricks machine moulded conforming to IS:4139, having 100 kg/cm2 average compressive strength in super structure above plinth level upto floor II level in : 6.8.1 Cement mortar 1:4 (1 cement : 4 sand) 6.8.2 Cement mortar 1:6 (1 cement : 6 sand) 127 6.9 Brick work with extruded burnt fly ash clay sewer bricks (Conforming to IS: 4885 ) in foundation and plinth : Cement Mortar 1:4 ( 1 cement : 4 sand) 128 6.10 Brick work with extruded burnt fly ash clay sewer bricks (conforming to IS: 4885) in archesin foundation and plinth including centering and shuttering complete in cement mortar 1:3 (1 cement: 3 sand). 129 6.11 Extra for brick work in superstructure above floor two levels for each additional floor or part thereof respective item. 130 6.12 Providing half brick masonry with well burnt chimney bricks in bull patent trench kiln manufactured by ghol process crushing strength not less than 40 kg /cm2 and water absorption not more than 15% in superstructure above plinth level and up to floor two level. 6.12.1 Cement mortar 1:3 (1 cement : 3 sand) 6.12.2 Cement mortar 1:4 (1 cement : 4 sand) 131 6.13 Providing half brick masonry with well burnt chimney bricks in bull pattern trench kiln crushing strength not less than 25 kg /cm2 and water absorption not more than 20% in superstructure above plinth level and up to floor two level. 6.13.1 Cement mortar 1:3 (1 cement : 3 sand) 6.13.2 Cement mortar 1:4 (1 cement : 4 sand) 132 6.14 Providing half brick masonry with well burnt open bhatta bricks crushing strength not less than 25 kg /cm2 and water absorption not more than 20% in superstructure above plinth level and up to floor two level 6.14.1 Cement mortar 1:3 (1 cement : 3 sand) 6.14.2 Cement mortar 1:4 (1 cement : 4 sand) 133 6.15 Half brick masonry with fly ash lime Gypsum bricks (FALG bricks) conforming to IS: 12894, in super structure above plinth and upto floor two level. 6.15.1 Having 100 kg/cm2 average compressive strength. 6.15.1.1 Cement mortar 1 : 3 (1 cement : 3 sand) 6.15.1.2 Cement mortar 1 : 4 (1 cement : 4 sand) 6.15.2 Having 75 kg/cm2 average compressive strength. 6.15.2.1 Cement mortar 1 : 3 (1 cement : 3 sand) 6.15.2.2 Cement mortar 1 : 4 (1 cement : 4 sand) 6.15.3 Having 50 kg/cm2 average compressive strength. 6.15.3.1 Cement mortar 1 : 3 (1 cement : 3 sand) 6.15.3.2 Cement mortar 1 : 4 (1 cement : 4 sand) 134 6.16 Extra for half brick masonry in superstructure, above floor two level for every floor or part thereof respective item. 135 6.17 Extra for providing and placing in position 2 Nos. 8mm dia. M.S. bars at every third course of in half brick masonry. 136 6.18 Honey-comb brick work 10 cm thick with well burnt chimney bricks manufactured by ghol process crushing strength not less than 40kg /sqcm and water absorption not more than 15% in cement mortar 1:4 (1 cement : 4 sand). 137 6.19 Extra for forming cavity 5cm to 7.5cm wide in cavity walls with necessary weep and vent holes including use of cores and cost of providing and fixing bitumastic coated M .S. Ties 300mm long of 25x3mm section at not less than 3 ties per sqm as per approved design 138 6.20 Brick work in plain arches in superstructure including centering and shuttering complete with chimney bricks having crushing strength not less than 40kg /cm2 and water absorption not more than 15% in cement mortar 1:3 (1 cement : 3 sand). 139 6.21 Brick work in gauged arches in superstructure in cement mortar 1:3 (1 cement : 3 sand) including centering and shuttering complete, with chimney bricks having crushing strength not less than 40kg /cm2 and water absorption not more than 15% 140 6.22 Providing half brick masonry with kiln burnt clay bricks of 40kg /cm2 and water absorption not more than 15% in cement mortar 1:3 (1 Cement : 3 sand) in superstructure for closing cavity 5 to 7.5 cm wide in cavity wall complete with 10 cm wide bitumen felt type 3 grade 1. 141 6.23 Extra for laying brick work in or under water and/or liquid mud including cost of pumping or bailing out water and removing slush etc. complete.NOTE: - The quantity will be calculated by multiplying the depth measured from sub - soil water level up to the centre of gravity of brick work in cum executed under the sub - soil water. The depth of centre of gravity shall be reckoned correct to 0.1 m. 0.05 m or more shall be taken as 0.1 m and less than 0.05 m ignored. 142 6.24 Extra for laying brick work in or under foul position. 143 6.25 Providing and laying cellular concrete blocks masonry having density ranging from 800kg/m3 in super structure above plinth level up to floor two level in cement mortar 1:4 (1 cement: 4 sand) The nominal dimensions of the concrete blocks shall be as follows in additional block shall be of half lengths of 200, 250 or 300 mm to correspond to the full lengths. The size of the blocks specified other than those specified may also be used. 144 6.26 Providing and laying Autoclaved Aerated Concrete (AAC) blocks masonry, using AAC blocks (Size length 300, 400, 500, 600 mm Height 200, 250, 300 mm Width 100, 150, 200, 250 mm) conforming to IS 2185 PART 3, having compressive strength not less than 4 MPa (Grade II) in super structure, blocks jointed with approved block laying polymer modified adhesive mortar as per ASTM international standard including raking out joints. Vertical bands shall be placed along jams (vertical member of chowkhats) and extend upto lintel levels to arrest cracking at corner openings. RCC bands shall be measured with AAC block masonry. Rates include all materials including steel bars, wastages, scaffolding and all labour etc. complete. 6.26.1 AAC Masonry in polymer modified mortar 145 6.27 Extra for AAC masonry work in superstructure above floor two level for each additional floor or part thereof 146 6.28 Providing hoisting & fixing precast Autoclaved Aerated Concrete (AAC) reinforced roof slabs, lintels and chhajjas as per IS: 6073 -2006 grade D specifications (dry density, without steel, 550 kg/m3 to 650 kg/m3 and minimum compressive strength 3.5 N/mm2) reinforcement steel provided inside AAC slab, lintel and chhajja shall be ascertained on the basis of manufacturer’s certificate and also by random destructive testing done by engineer-in-charge or his representative for which cost of samples and testing charges shall be borne by the contractor. Deflection & ultimate load test for AAC reinforced roof slab and lintel shall be as per annex. B of IS: 6073 -2006 and criteria for conformity and sampling shall be as per clause-13 of IS: 6073 -2006. 147 6.29 Precast autoclaved aerated concrete (AAC) reinforced wall panels:- Providing hoisting & fixing precast Autoclaved Aerated Concrete (AAC) reinforced wall panels as per IS:6072 -1972 grade D (dry density, without steel, 550 kg/m3 to 650 kg/m3 and inside AAC panels. Quantity of reinforcement steel in AAC panels shall be ascertained on the basis of certificate of the manufacturer and also by random destructive testing by engineer-in- charge or his representative for which cost of samples and testing charges shall be borne by the contractor. Cost of reinforcement inside AAC panels shall be paid separately. 148 6.30 Add extra for AAC wall panels, roof slabs, lintels and chhajjas above floor two level for each additional floor as per item no 6.29 and 6.30. 149 6.32 Brick work with common burnt clay selected F.P.S. (non modular) bricks of class designation 7.5 in exposed brick work including making horizontal and vertical grooves 10 mm wide 12 mm deep complete in cement mortar 1:6 (1 cement : 6 coarse sand) 6.32.1 From ground level upto plinth level 6.32.2 Above plinth level upto floor II level 150 6.33 Brick work with modular bricks of class designation 7.5 in exposed brick work including making horizontal and vertical grooves 10mm wide 12mm deep complete from ground level up to plinth level in cement mortar 1:6 (1 cement : 6 coarse sand) 6.33.1 From ground level upto plinth level 6.33.2 Above plinth level upto floor II level 151 6.34 Providing and laying Gypsum panel partitions 100 mm thick with water proof Gypsum panels of size 666x500x100 mm, made of calcite phosphor Gypsum fixed with tongue and groove, jointed with bonding plaster as per manufacturer’s specifications in superstructure above plinth level up to floor two level. Gypsum blocks will have a minimum compressive strength of 9.3 kg/cm2 152 6.35 Extra for Gypsum panel Partitions in superstructure above floor two level for every four floors or part thereof. 153 7.1 Random rubble masonry with hard stone in foundation and plinth including leveling up with cement concrete 1:6:12 (1 cement :6 sand : 12 graded stone aggregate 20mm nominal size) at plinth level with : 7.1.1 Cement mortar 1:6 (1 cement : 6 sand) 154 7.2 Random rubble masonry with hard stone in superstructure above plinth level and upto floor two level, including leveling up with cement concrete 1:6:12 (1 cement : 6 sand : 12 graded stone aggregate 20mm nominal size) at window sills, ceiling level and the like. 7.2.1 Cement mortar 1:6 (1cement: 6 sand). 155 7.3 Extra for random rubble masonry with hard stone in superstructure above floor two level for every floors or part thereof 156 7.4 Extra for random rubble masonry with hard stone in : 7.4.1 Square or rectangular pillars 7.4.2 Circular pillars. 157 7.5 Extra for random rubble masonry with hard stone curved on plan for a mean radius not exceeding 6 m. 158 7.6 Coursed rubble masonry (1st or 2nd sort) with hard stone in foundation and plinth. 7.6.1 Cement mortar 1:6 (1 cement : 6 sand) 7.6.2 Cement mortar 1:6 (1 cement : 6 sand) 159 7.7 Coursed rubble masonry with hard stone (first or second sort) in superstructure above plinth level and upto floor two level. 7.7.1 Masonry work (first sort) in cement mortar 1:6 (1 cement : 6 sand) 7.7.2 Masonry work (second sort) , in cement mortar 1:6 (1 cement : 6 sand) 160 7.8 Extra for coursed rubble masonry with hard stone (first or second sort) in superstructure above floor two level for every floors or part thereof 161 7.9 Extra for coursed rubble masonry with hard stone (first or second sort) in : 7.9.1 Square or rectangular pillars 7.9.2 Circular pillars. 7.9.3 Extra for coursed rubble masonry with hard stone (first or second sort) curved on plan for a mean radius not exceeding 6 m. 162 7.10 Stone work in plain ashlar masonry in super structure upto floor two level in cement mortar 1:6 (1 cement : 6 sand) including pointing with cement mortar 1:2 (1 white cement : 2 marble dust) with an admixture of pigment matching the sand stone shade : 7.10.1 One face dressed. 7.10.1.1 Red sand stone 7.10.1.2 White sand stone 7.10.2 Both face dressed. 7.10.2.1 Red sand stone. 7.11.2.2 White sand stone 163 7.11 Stone work plain ashlar masonry in arches in super structure upto floor two level in cement mortar 1:3 (1 cement: 3 sand) including centering, shuttering and pointing with white cement mortar 1:2 (1 white cement: 2 marble dust) with an admixture of pigment matching the sand stone shade. 7.11.1 One face dressed. 7.11.1.1 Red sand stone 7.11.1.2 White sand stone 7.11.2 Both face dressed. 7.11.2.1 Red sand stone. 7.11.2.2 White sand stone 164 7.12 Stone work plain ashlar masonry in domes, in super structure upto floor two level in cement mortar 1:3 (1 cement: 3 sand) including centering, shuttering and pointing with white cement mortar 1:2 (1 white cement: 2 marble dust) with an admixture of pigment matching the sand stone shade. 7.12.1 One face dressed 7.12.1.1 Red sand stone 7.12.1.2 White sand stone 7.12.2 Both face dressed. 7.12.2.1 Red sand stone. 7.12.2.2 White sand stone. 165 7.13 Stone work ashlar masonry punched (ordinary) in superstructure above plinth level and upto floor two level in cement mortar 1:6 (1 white cement: 6 sand) including pointing with cement mortar 1:2 (1 white cement: 2 marble dust) with an admixture of pigment matching the sand stone shade. 7.13.1 Red sand stone one face punched. 7.13.2 Red sand stone both face punched 7.13.3 White sand stone one face punched. 7.13.4 White sand stone double face punched 166 7.14 Extra for stone work, plain ashlar or ashlar punched above floor two level for every floor or part thereof. 167 7.15 Extra for plain ashlar or ashlar punched in : 7.15.1 Square or rectangular pillars 168 7.16 Extra for stone work; plain ashlar or ashlar punched in curved on plan with a mean radius not exceeding 6 m. 169 7.17 Extra for additional cost of centering for arches exceeding 6m span including all strutting, bolting, wedging etc. And removal (area of soffit to be measured). 170 7.18 Stone work sunk or moulded or sunk and moulded upto floor Two level in cement mortar 1:6 (1cement : 6 sand) including pointing with white cement mortar 1:2 (1 white : 2 marble dust) with an admixture of pigment matching the stone shade : 7.18.1 Red sand stone 7.18.2 White sand stone 171 7.19 Extra for stone work sunk or moulded or sunk and moulded or carved in : 7.19.1 Triangular or Square or rectangular pillars 7.19.2 Circular or polygonal pillars 172 7.20 Extra for stone work sunk or moulded in cornices. 173 7.21 Stone work (machine cut edges) for wall lining etc. (veneer work) up to 10 meter height backing filled with a grout of 12mm thick cement mortar 1:3 (1 cement : 3 sand) including pointing in white cement mortar 1:2 (1 white cement : 2 marble dust) with an admixture of pigment matching the stone shade : (To be secured to the backing by means of clamps which shall be paid for separately): 7.21.1 Red sand stone - exposed face fine dressed with rough backing. 7.21.1.1 70 mm thick. 7.21.1.2 60 mm thick. 7.21.1.3 50 mm thick 7.21.1.4 40 mm thick. 7.21.1.5 30 mm thick. 7.21.2 Red sand stone - Exposed face machine cut and table rubbed with rough backing. 7.21.2.1 70 mm thick. 7.21.2.2 60 mm thick. 7.21.2.3 50 mm thick 7.21.2.4 40 mm thick. 7.21.2.5 30 mm thick. 7.21.3 White sand stone - exposed face fine dressed with rough backing. 7.21.3.1 70 mm thick. 7.21.3.2 60 mm thick. 7.21.3.3 50 mm thick 7.21.3.4 40 mm thick. 7.21.3.5 30 mm thick. 7.21.4 White sand stone - Exposed face machine cut and table rubbed with rough backing. 7.21.4.1 70 mm thick. 7.21.4.2 60 mm thick. 7.21.4.3 50 mm thick 7.21.4.4 40 mm thick. 7.21.4.5 30 mm thick. 174 7.22 Extra for stone work (veneer work) curved on plan with a mean radius not exceeding 6 m. 175 7.23 Providing and fixing stainless steel cramps of required size and shape for anchoring stone wall lining to the backing or securing adjacent stones in stone wall lining in cement mortar 1:2 (1 cement :2 sand) including making the necessary chases in stone and holes in walls wherever required. 176 7.24 Providing and fixing stone dowels of size 10x5x2.5cm cut to double wedge shape as per design in cement mortar 1:2 (1 cement : 2 sand) including making the necessary chases 177 7.25 Providing and fixing copper pins 7.5 cm long 6 mm diameter for securing adjacent stones in stone wall lining in cement mortar 1:2 (1 cement : 2 sand) including making the necessary chases. 178 7.26 Providing and fixing sloping chajja of stone 40 mm thick and upto 80 cm wide beyond the wall as measured along the slope in cement mortar 1:4 (1 cement : 4 sand) including pointing in cement mortar 1:2 (1 white cement: 2 marble dust) with an admixture of pigment matching the stone shade: 7.26.1 Red sand stone: With common burnt clay bricks of 25 kg/cm2 compressive strength. 7.26.2 White sand stone: With common burnt clay bricks of 25 kg/cm2 compressive strength. 179 7.27 Providing and fixing horizontal chajja of stone 40 mm thick and upto 80 cm projection in cement mortar 1:4 (1 cement : 4 sand) including pointing in white cement mortar 1:2 (1 white cement : 2 marble dust) with an admixture of pigment matching the stone shade: 7.27.1 Red sand stone 7.27.2 White sand stone 180 7.28 30mm red sand stone sun-shade (chisel-dressed) supported on red sand stone brackets, fixed in walls with cement mortar 1:4 (1 cement: 4 sand) including finishing complete. 181 7.29 Providing and fixing red sand stone brackets 55x22.5x45cm sunk and moulded including providing and fixing with 4 Nos. gun metal cramp 25x6mm 30 cm long and dowel bars 7.5 cm long 6 mm dia as per design. 182 7.30 Stone work, plain in copings, cornices, string courses and plinth courses, upto 75 mm thick in Cement mortar 1:6 (1 cement : 6 sand) including pointing with white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade. 7.30.1 Red sand stone 7.30.2 White sand stone 183 7.31 Providing and fixing stone jali 40mm thick throughout in cement mortar 1:3 (1cement :3 sand) including pointing in white cement mortar 1:2 (1white cement: 2stone dust) with an admixture of pigment , matching the stone shade, jali slab without any chamfers etc. 7.31.1 Red sand stone 7.31.2 White sand stone 184 7.32 Extra for laying stone work in or under water and/or liquid mud including cost of pumping or bailing out water and removing slush etc. complete.NOTE: - The quantity will be calculated by multiplying the depth measured from sub - soil water level up to the centre of gravity of stone work in cum executed under the sub - soil water. The depth of centre of gravity shall be reckoned correct to 0.1 m. 0.05 m or more shall be taken as 0.1 m and less than 0.05 m ignored. 185 7.33 Extra for laying stone work in or under foul position. 186 7.34 Wall lining butch work upto 10m height with red/ white sand stone 40 mm thick rough facing on the exposed surface with stone strips of minimum length 300 mm and required width 75mm thick strips i/c 12mm thick bed of cement mortar 1:3 (1 Cement : 3 sand) i/c ruled pointing in cement mortar 1:2 (1 white cement: 2 marble dust) with an admixture of pigment to match the shade of stone complete as per direction of Engineer-in- charge. 187 7.35 Stone work ( machine cut edges) for wall lining upto 10 m height etc. (Veneer work) backing filled with a grout of 12mm thick cement mortar 1:3 (1 Cement : 3 sand) and jointed with Cement mortar 1:2 (1 cement : 2 marble dust) including rubbing and polishing complete. (To be secured to the backing by means of cramps which shall be paid for separately) 7.35.1 25mm thick Kota stone slabs exposed face dressed and rubbed. 7.35.2 25mm thick Dholpur stone slabs exposed face dressed and rubbed. 7.35.3 20 to 25mm thick kota stone slabs exposed slab not dressed and rubbed. 7.35.4 20 to 25mm thick Dholpur stone/shivpuri stone not dressed and rubbed. 188 7.36 Stone tile work with 8mm thick mirror polished and machine cut edge for wall lining upto 10 m height with special adhesive over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 sand), including pointing in white cement with an admixture of pigment to match the stone shade. 7.36.1 Granite stone of any colour and shade 7.36.2 Raj Nagar plain white marble/ Udaipur green marble/ Zebra black marble 189 7.37 Extra for stone work for wall lining on exterior walls of height more than 10 m from ground level for every additional height of 3 m or part thereof. 190 7.38 Providing and fixing dry stone cladding upto 10 metre height with 30mm thick gang saw cut stone with (machine cut edges) of uniform colour and/ or with the help of cramps, pins etc. And sealing the joints with approved weather sealant as per Architectural drawing and direction of Engineer-in-charge. (The steel frame work, stainless steel cramps and pins. shall be paid for separately.) 7.38.1 Red sand stone. 7.38.2 White sand stone 191 7.39 Providing and fixing structural steel frame (for dry stone cladding with 30 mm thick gang saw cut with machine cut edges sand stone) on walls at all heights using M.S. square/rectangular tube in the required pattern as per architectural drawing including including drilling necessary steel work will be given a priming coat of Zinc primer as approved by Engineer-in-charge and painted with two or more coats of epoxy paint (Shop drawings shall be submitted by the contractor to the Engineer-in-charge for approval before execution).The frame work shall be fixed in true horizontal and vertical lines/ planes. (Only structural steel frame work shall be measured for the purpose of payment, stainless steel clamps shall be paid for separately and nothing extra shall be paid.) 192 7.40 Providing and fixing adjustable stainless steel clamps of approved quality and of required shape and size adjustable with stainless steel nuts bolts and washer (total weight not less than 260 gms) for dry stone cladding fixed on frame 193 8.1 Providing and supplying aluminium extruded tubular and other aluminium sections frame work as per the architectural drawings and approved shop drawings, the aluminium quality as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coated of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in-Charge. (The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account). 194 8.2 Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of aluminium structural glazing (with open joints) for linear as well as curvilinear portions of the building for all heights and all levels.. (A) Structural analysis anddesign and preparation of shopdrawings for the specified designloads conforming to IS 875 partIII (the system must passed theproof test at 1.5 times design wind pressure without any failure), including functional design of the aluminum sectionsBfor fixing glazing panels of various thicknesses, aluminum cleats, sleeves and splice plates etc. gaskets, screws, toggles, nuts, bolts, clamps etc., structural and weather silicone sealants, flashings, fire stop (barrier)-cum-smoke seals,microwave cured EPDM gaskets for water tightness, pressure equalisation and drainage andprotection against fire hazard including (B) Fabricating and supplying serrated M.S. hot dip galvanised / Aluminum alloy of 6005 T5 brackets of required sizes, sections and profiles etc. toaccommodate 3 Dimentional movement for achieving perfect verticality and fixing structuralglazing system rigidly to the RCC/ masonry/structural steel framework of building structureusing stainless steel anchor fasteners/ bolts, nylon seperator to prevent bimetallic contactswith nuts and washers etc. of stainless steel grade 316, of the required capacity and in requirednumbers.(C) Providing and filling, two part pump filled, structural silicone sealant and one partweather silicone sealant compatible with the structural silicone sealant of required bitesize in a clean and controlled factory / work shop environment, including double sided spacer tape, setting blocks and backer rod, all of approved grade, brand and manufacture, as per the approved sealant design, within and all around the perimeter for holding glass.(D) Providing and fixing in position flashings of solid aluminum sheet 1 mm thick andof sizes, shapes and profiles, as required as per the site conditions, to seal the gap between the building structure and all its interfaces with curtain glazing to make it watertight(E) Making provision for drainage of moisture/ water that enters the curtain glazing systemto make it watertight, by incorporating principles of pressure equalization, providing suitable gutter profiles at bottom (if required), making necessary 195 8.3 Providing, assembling and supplying vision glass panels (IGUs) comprising of hermetically-sealed 6-12- 6 mm insulated glass (double glazed) vision panel units of size and shape as required and specified, comprising of an outer heat strengthened float glass 6mm thick, of approved colour as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer-in-Charge. The IGUs shall be assembled in the factory/ workshop of the glass processor. (Payment for fixing of IGU Panels in the curtain glazing is included in cost of item No.8.2) For payment, only the actual area of glass on face # 1 of the glass panels (excluding the areas of the grooves and weather silicone sealant) provided and fixed in position, shall be measured in sqm. 196 8.4 Extra for openable side / top hung vision glass panels (IGUs) including providing and supplying at site all accessories and hardwares for the openable panels as specified and of the approved make such as heavy duty stainless steel friction hinges, min 4 -point cremone locking sets with stainless steel plates, handles, buffers etc. including necessary stainless steel screws/ fasteners, nuts, bolts, washers etc. all complete as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineerin- Charge. 197 8.5 Providing, fabricating and supplying shadow box of required size and shape, for fixing in the spandrel portion of the structural glazing, in linear as well as curvilinear portions of the building by providing semi - rigid, inorganic, non- combustible fibre glass wool insulation 50 mm thick having density 48 kg/m3, conforming to IS: 8183 and BS: 3958 Part 5.The insulation layer shall have facing (factory bonded on surface # 1 of the fibre glass insulation layer), of black non- woven fibre glass tissue of nominal thickness 0.5 mm and nominal mass not less than 60 gm/sqm, made of randomly oriented glass fibres distributed in a binder by a wet-lay process including fixing 1.5 mm thick solid aluminum sheet backing using, 6 mm thick cement board including SS rivets, nuts, bolts, washers etc complete. 198 8.6 Providing and supplying Spandrel Glass Panels comprising of 6 mm thick heat strengthened monolithic float glass of approved colour and shade with reflective soft coating on surface # 2 of approved colour and shade so as to match the colour and shade of the IGUs in the vision panels etc., included in cost of relevent Item). (i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face # 2, having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25- 0.28) and U value of 3.0 to 3.3 W/m2 degree K etc. The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement. 199 8.7 Designing, fabricating, testing, installing and fixing in position Curtain Wall with Aluminium Composite Panel (ACP) Cladding, with open grooves for linear as well as curvilinear portions of the building, for all heights and all levels etc. including: with aluminium composite panel cladding, having all the performance characteristics all complete, as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer- in-Charge. However, for the purpose of payment, only the actual area on the external face of the curtain wall with Aluminum Composite Panel Cladding (including width of groove) shall be measured in sqm. upto two decimal places. 8.7.1 4 mm thick alumminium composite pannel material consisting of 3 mm thick FR grade mineral core sandwiched between two alumminium sheets (each 0.5mm thick) 8.7.2 4 mm thick alumminium composite pannel material consisting of 3.5 mm thick FR grade mineral core sandwiched between two alumminium sheets (each 0.25mm thick) 8.7.3 3 mm thick alumminium composite pannel material consisting of 2.5 mm thick FR grade mineral core sandwiched between two alumminium sheets (each 0.25mm thick) 200 8.8 Design, supply and installation of suspended Spider Glazing system designed to withstand the wind pressure as pr IS 875 (Part- III). The Suspended System held with Spider Fittings of SS-316 Grade Steel of approved manufacturer with glass panel having 12 mm thick clear toughened glass held together with SS- 316 Grade Stainless steel Spider and other incidental charges including wastage, enabling temporary services all fitting fixers nut bolts, washer, Buffer plates, fastener, anchors, SS channel laminated glass etc. all complete.For the purpose of payment actual elevation area of Glazing including thickness of joints and the portion of Glass panel inside the SS channel shall be measured., 201 8.9 Providing and fixing aluminium magnesium alloy (FACADE) wall cladding system consisting of panels 200mm wide x 17mm deep x 0.5mm thick of maximum length of 6.0 mtr. coil coated on a continuous paint line double baked and roll formed from centre to centre at a distance of maximum 1.20 mtr. The stringer shall be fixed to a suitable rigid structure. All panels shall be achromatised for maximum bond between metal and paint, enamelled twice under high temperature one side with full primer and the other side (inner side) with a primer coat on a continuous paint line, and fixed as per the direction of the Engineer-in-Charge. 202 8.10 Providing and fixing Aluminium Magnesium alloy Plain Panel Sun Louvres of approved colour consisting of panel 84 mm wide x 16mm deep x 0.6mm thick with round edges panel length upto 6 mtrs coil coated on a continuos paint line double baked between metal and paint, enamelled twice under high temperature one side with full primer and finish, the other side (inner side) with a primer coat and Skin Coat on a Continuos Paint Line.Note: - 1. The cost of providing extruded aluminium frames, shadow boxes, extruded aluminium section capping for fixing in the grooves of the curtain glazing shall be paid for separately under relevant items under this subhead. However, for the purpose of payment, only the actual area of structural glazing (including width of grooves) on the external face shall be measured in sqm. upto two decimal places. 203 9.1 Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia and length (hold fast lugs or dash fastener shall be paid for separately). 9.1.1 Second class teak wood 9.1.2 Sal wood 9.1.3 Kiln Head wood seasoned and chemically treated hard wood (Haldu, Kail, Bija wood.) 9.1.4 Factory made Kiln seasoned, chemically treated, finger jointed at spacing not closer than 50 cm, 2nd class hard wood. 9.1.4.1 Frame of size 100mmX60mm single or double rebate 9.1.4.2 Frame of size 120mmX60mm double rebate. 205 9.2 Providing laminated veneer lumber conforming to IS:14616 and TAD -15: 2001(Part-B) in factory made frames of doors, windows, clerestory windows and other frames, wrought framed and fixing in position with hold fast lugs or with dash fasteners of required dia and length ( hold fast lugs or dash fastener shall be paid for separately). 206 9.3 Providing wood work in frames of false ceiling, partitions etc. sawn and fixed in position ( with necessary stainless steel screw) 9.3.1 Sal wood 9.3.2 Kiln seasoned and chemically treated hardwood Haldu, Kail, Bija wood. 9.3.3 Factory made Kiln seasoned, chemically treated, finger jointed at spacing not closer than 50 cm, 2nd class hard wood. 207 9.4 Extra for additional labour wood work in circular shape, such as in frames of fan light : 9.4.1 Second class teak wood 9.4.2 Sal wood 9.4.3 Kiln seasoned and chemically treated Haldu, Kail, Bija wood. 9.4.4 Factory made Kiln seasoned, chemically treated, finger jointed at spacing not closer than 50 cm, 2nd class hard wood. 208 9.5 Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws excluding, panelling/glazing which will be paid for separately, all complete as per direction of Engineer-in-charge. 9.5.1 Second class teak wood 9.5.1.1 35 mm thick shutters 9.5.1.2 30 mm thick shutters 9.5.2 Kiln seasoned and chemically treated hardwood Haldu, Kail, Bija wood. 9.5.2.1 35 mm thick shutters 9.5.2.2 30 mm thick shutters 9.5.3 Kiln seasoned selected planks of sheesham wood. 9.5.3.1 35 mm thick shutters 9.5.3.2 30 mm thick shutters 9.5.4 Factory made Kiln seasoned chemically treated and finger jointed at spacing not closer than 50cm, 2nd class hard wood shutters 9.5.4.1 35 mm thick 9.5.4.2 30 mm thick 209 9.6 Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick: 9.6.1 Second class teak wood 9.6.2 Kiln seasoned and chemically treated Haldu, Kail, Bija wood 9.6.3 15mm thick Factory made Kiln seasoned, chemically treated and finger jointed at spacing not closer than 50cm, 2nd class hard wood. 9.6.4 Ply wood 5 ply, 9 mm thick : 9.6.4.1 Decorative plywood both side decorative veneer (Type - I) conforming to IS 1328 BWR type. 9.6.4.2 Decorative plywood one side decorative veneer and commercial veneer on other face (Type 1) conforming to IS 1328 BWR Type 9.6.5 Ply wood 7 ply, 9 mm thick : 9.6.5.1 Decorative plywood both side decorative veneer (Type- I) conforming to IS 1328 BWR type. 9.6.5.2 Decorative plywood one side decorative veneer and commercial veneer on other face (Type-1) conforming to IS 1328 BWR Type 9.6.6 Particle Board 12 mm thick 9.6.6.1 Plain particle board flat pressed, 3 layer or graded wood particle board medium density Grade I, IS: 3087 marked. 9.6.6.2 Veneered flat pressed three layer or graded wood particle board with commercial veneering on both sides conforming to IS: 3097, grade I. 9.6.6.3 Pre-laminated particle board with decorative lamination on one side and balancing lamination on other side, Grade I, Type II IS: 12823 marked. 9.6.6.4 Pre-laminated particle board with decorative lamination on both sides, Grade I, Type II, IS: 12823 marked. 9.6.6.5 Coir Veneer Board (conforming to IS 14842) 12 mm thick 9.6.7 Float glass panes 9.6.7.1 4 mm thick glass pane (weight not less than 10 kg/sqm) 9.6.7.2 5 mm thick glass pane (weight not less than 12.5 kg/sqm) 9.6.8 Fly proof stainless steel grade 304 wire gauge with 0.5 mm dia. Wire and 1.4 mm wide aperture with matching wood beading 9.6.8.1 4mm to 5mm thick integral PVC form sheet with Celluka finish surface on both side with density not less than 600 kg/cum 9.6.8.2 4mm to 5mm thick laminated PVC form sheet with density not less than 600 kg/cum, laminated on both sides by 0.12 mm thick laminated sheet with density not less than 1400 kg/cum 210 9.7 Providing and fixing 35 mm thick factory made laminated veneer lumber door shutter conforming to IS : 14616 and TADS 15:2001 (Part B) including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws, all complete as per directions of Engineer-in- charge and panelling with panels of: 9.7.1 12mm thick plain grade - 1, medium density flat pressed three layer particle board FPT - I or graded wood particle board FPT - I IS : 3087 marked bonded with BWP type synthetic resin adhesive as per IS : 848 : 9.7.2 12 mm thick pre-laminated particle board (decorative lamination on both sides) grade - 1, medium density flat pressed, three layer particle board FPT - I or graded wood particle board FPT - I, conforming to IS : 3087 bonded with BWP type synthetic resin adhesive as per IS : 848 and pre- lamination conforming to IS : 12823 Grade 1, Type - II marked: 9.7.3 12 mm thick one side pre-laminated particle board (decorative lamination on one side and other sides balancing lamination) grade - 1 medium density flat pressed, three layer particle board FPT - I or graded wood particle board FPT-1 conforming to IS : 3087 bonded with BWP type synthetic resin adhesive as per IS : 848 and prelamination conforming to IS : 12823 Grade -1, Type II marked: 211 9.8 Providing and fixing glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws. 9.8.1 Second class teak wood 9.8.1.1 35 mm thick 9.8.1.2 30 mm thick 9.8.2 Kiln seasoned and chemically treated Haldu, Kail, Bija wood 9.8.2.1 35 mm thick 9.8.2.2 30 mm thick 9.8.3 Kiln seasoned selected planks of sheesham wood. 9.8.3.1 35 mm thick 9.8.3.2 30 mm thick 9.8.4 Factory made Kiln seasoned chemically treated and finger jointed at spacing not closer than 50cm, 2nd class hard wood 9. 8.4.1 30 mm thick shutters 9. 8.4.2 35 mm thick shutters 212 9.9 Providing and fixing factory made laminated veneer lumber glazed shutter conforming to IS: 14616 and TADS 15:2001 (Part B) , using 4mm thick float glass panes for doors, windows and clerestory windows including ISI marked fixing with M.S. pressed butt hinges bright finished of required size with necessary screws as per directions of Engineer-in- charge. 30 mm thick shutters. 213 9.10 Extra for providing heavy sheet float glass panes instead of ordinary float glass in glazed doors, windows and clerestory window shutters. (Area of opening for glass panes excluding portion inside rebate shall be measured) 9.10.1 5 mm thick instead of 4 mm thick. 9.10.2 10 to 12 mm float glass 9.10.3 5.5 mm safety glass 9.10.4 10-12mm safety glass 214 9.11 Extra for providing frosted glass panes 4 mm thick instead of ordinary float glass panes 4 mm thick in doors, windows and clerestory window shutters. (Area of opening for glass panes excluding portion inside rebate shall be measured). 215 9.12 Deduct for providing pin headed glass panes instead of ordinary float glass panes 4 mm thick in doors, windows and clerestory windows, shutters (Area of opening for glass panes excluding portion inside rebate shall be measured). 216 9.13 Extra for S.S, hinges providing ISI marked Stainless Steel butt hinges instead of M.S. pressed butt hinges bright finished of required size with necessary screws. (Shutter area to be measured). 217 9.14 Deduct for not providing hinges in doors, windows or clerestory window shutters with : 9.14.1 Stainless steel butt hinges with stainless steel screws for 2nd class teak wood and other class of wood shutters. 9.14.2 ISI marked M.S. pressed butt hinges bright finished of required size For 2nd class teak wood and other class of wood shutters. 218 9.15 Providing and fixing 25 mm thick Second class teak wood shutters using 4mm float glass for cup board etc. : 9.15.1 Panelled or panelled and glazed shutters : 9.15.1.1 Using ISI marked anodised aluminium butt hinges with necessary screws. 9.15.1.2 Using ISI marked nickel plated bright finished M.S. piano hinges with necessary screws. 9.15.2 Glazed shutters : 9.15.2.1 Second class teak wood including ISI marked anodised aluminium butt hinges with necessary screws. 9.15.2. 2nd class teak wood including ISI marked nickel plated bright finished M.S. piano hinges with necessary screws. 219 9.16 Providing and fixing flat pressed 3 layer particle board medium density exterior grade (Grade I) or graded wood particle board IS : 3087 marked to frame, backing or studding with screws etc. complete (Frames, backing or studding to be paid separately) : 9.16.1 12 mm thick 9.16.2 18 mm thick 220 9.17 Providing and fixing Pre-laminated flat pressed 3 layer (medium density) particle board or graded wood particle board IS : 3087 marked with one side decorative and other side balancing lamination Grade I, Type II exterior grade IS : 12823 marked in shelves with screws and fittings wherever required, edges to be painted with polyurethane primer (fittings to be paid separately). 9.17.1 18 mm thick 9.17.2 25 mm thick 221 9.18 Providing and fixing ISI marked flush door shutters conforming to IS: 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutter. 9.18.1 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws. 9.18.2 30 mm thick including ISI marked Stainless Steel butt hinges with necessary screws. 9.18.3 25 mm thick (for cupboard) including ISI marked nickel plated bright finished M.S. Piano hinges IS: 3818 marked with necessary screws. 222 9.19 Providing and fixing ISI marked flush door shutters conforming to IS: 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 9.19.1 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws. 9.19.2 30 mm thick including ISI marked Stainless Steel butt hinges with necessary screws. 9.19.3 25mm thick (for cupboard) including ISI marked nickel plated bright finished M.S. piano hinges with necessary screws. 223 9.20 Extra for Providing and fixing flush doors with decorative veneering instead of non decorative ISI marked flush door shutters conforming to IS: 2202 (Part I) On one side only. 224 9.21 Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). 225 9.22 Extra for providing vision panel not exceeding 0.1 sqm in all type of flush doors (cost of glass excluded) (overall area of door shutter to be measured) : 9.22.1 Rectangular or square. 9.22.2 Circular. 226 9.23 Extra if louvers (not exceeding 0.2 sqm) are provided in flush door shutters (overall area of door shutters to be measured). 227 9.24 Extra for cutting rebate in flush door shutters (Total area of the shutter to be measured). 228 9.25 Providing and fixing wire gauze shutters using galvanised M.S. wire gauze of average width of aperture 1.4mm in both direction with wire of dia. 0.63 mm for doors, windows and clerestory windows with hinges and necessary screws: 9.25.1 35 mm thick shutters with ISI marked M.S. pressed butt hinges bright finished of required size. 9.25.1.1 Second class teak wood. 9.25.1.2 Kiln seasoned and chemically treated Haldu, Kail, Bija wood. 9.25.1.3 Kiln seasoned selected class of sheesham wood. 9.25.2 35 mm thick shutters with ISI marked stainless steel butt hinges of required size. 9.25.2.1 Second class teak wood. 9.25.2.2 Kiln seasoned and chemically treated Haldu, Kail, Bija wood. 9.25.2.3 Kiln seasoned selected class of sheesham wood. 9.25.3 30 mm thick shutters with ISI marked M.S. pressed butt hinges bright finished of required size. 9.25.3.1 Second class teak wood. 9.25.3.2 Kiln seasoned and chemically treated Haldu, Kail, Bija wood. 9.25.3.3 Kiln seasoned selected class of sheesham wood. 9.25.4 30 mm thick shutters with ISI marked stainless steel butt hinges of required size. 9.25.4.1 Second class teak wood. 9.25.4.2 Kiln seasoned and chemically treated Haldu, Kail, Bija wood. 9.25.4.3 Kiln seasoned selected class of sheesham wood. 229 9.26 Providing and fixing wire gauge laminated veneer lumber shutters conforming to IS : 14616, and as per TADS 15 :2001 (Part B) using galvanised wire gauge with average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm as per IS :1568 for doors, windows and clerestory windows including ISI marked M.S. pressed fixing with butt hinges bright finished of required size with necessary screws as per directions of Engineer-in-charge: 9.26.1 35 mm thick shutters 9.26.2 30 mm thick shutters 230 9.27 Providing 50x50x50mm 2nd class teak wood plugs including cutting brick work and fixing in cement mortar 1:3 (1 cement : 3 sand) and making good the walls etc. 231 9.28 Providing and fixing expandable fasteners of specified size with necessary plastic sleeves and galvanised M.S. screws including drilling holes in masonry work /CC/ R.C.C. and making good etc. complete. 9.28.1 25 mm long 9.28.2 32 mm long 9.28.3 40 mm long 9.28.4 50 mm long 9.28.5 60 mm long 232 9.29 Providing and fixing 2nd class teak wood plain lining tongued and grooved including wooden plugs complete with necessary screws and priming coat on unexposed surface. 9.29.1 40 mm thick. 9.29.2 25 mm thick. 9.29.3 20 mm thick 9.29.4 12 mm thick 233 9.30 Providing and fixing in wall lining flat pressed three layer (medium density) particle board or graded wood Pre- laminated one side decorative lamination on other side balancing lamination Grade I, Type II, IS : 12823 marked including priming coat on unexposed surface, with necessary fixing arrangement and screws etc. complete : 9.30.1 12 mm thick 9.30.2 18 mm thick 9.30.3 25 mm thick 234 9.31 Providing and fixing specified wood frame work consisting of battens 50x25mm fixed with rawl plug and drilling necessary holes for rawl plug etc. including priming coat complete. Kiln seasoned and chemically treated Haldu, Kail, Bija wood. 235 9.32 Providing and fixing plywood 4 mm thick one side decorative veneer conforming to IS: 1328 (type-1) for plain lining / cladding with necessary screws, priming coat on unexposed surface with: Decorative veneer facings of approved manufacture. 236 9.33 Providing and fixing 4mm thick coir veneer board, ISI marked IS: 14842, plain lining with necessary screws, priming coat on unexposed surface etc., complete. 237 9.34 Providing and fixing skirting of Pre- laminated with (one side decorative and other side balancing lamination) flat pressed, 3 layer or graded particle board (medium density) Grade I, Type II, IS :12823 marked, with necessary fixing arrangements and screws including drilling necessary holes for rawl plugs etc. and priming coat on unexposed surface complete : 9.34.1 18 mm thick 9.34.2 25 mm thick 238 9.35 Providing and fixing wooden moulded beading to door and window frames with iron screws, plugs and priming coat on unexposed surface etc. complete : 9.35.1 2nd class teak wood 9.35.1.1 50x12 mm 9.35.1.2 50 x 20 mm 9.35.2 Kiln seasoned and chemically treated Haldu, Kail, Bija wood. 9.35.2.1 50x12 mm 9.35.2.2 50x20 mm 239 9.36 Providing and fixing plain jaffri of 35x10 mm laths placed 35 mm apart (frames to be paid separately) including fixing 50x12 mm beading complete with : Second class teak wood. 240 9.37 Providing and fixing 18 mm thick, 150 mm wide pelmet of flat pressed 3 layer or graded wood particle board medium density grade I, IS : 3087 marked,, including fixing with 25x3 mm M.S. flat 10 cm long fixed to pelmet with Haldu, Kail, Bija wood cleats of size 100 mm x 40 mm x 40 mm on both inner side of pelmet and rawl plugs 75 mm long etc. all complete. 241 9.38 Providing and fixing 18 mm thick, 150 mm wide pelmet of coir veneer board ISI marked IS: 14842, including top cover of 6 mm coir veneer board, nickle plated brackets, including fixing with 25x3 mm M.S. Flat 10 cm long fixed to pelmet with Haldu, Kail, Bija wood cleats of size 100 mm x 40 mm x 40 mm on both inner side of pelmet and rawl plugs 75 mm long etc. all complete. 242 9.39 Extra for using veneered particle board conforming to IS 3097 Grade I, in item of pelmet 18mm thick 150mm wide. 9.39.1 Non decorative veneer on both sides. 9.39.2 Particle board with decorative veneering on both sides. 243 9.40 Providing and fixing teak wood lipping of size 25x3 mm in pelmet. 244 9.41 Providing and fixing of 1.25 mm thick chromium plated brass plate, with two chromium plated curtain rods brass brackets fixed with C.P. brass screws and wooden plugs, etc., wherever necessary complete: 9.41.1 12 mm dia. 9.41.2 20 mm dia. 9.41.3 25 mm dia. 245 9.42 Providing and fixing nickel plated curtain rods M.S. pipe with nickel plated brackets : 9.42.1 20 mm dia (heavy type) 9.42.2 25 mm dia (heavy type) 246 9.43 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. 9.43.1 Fixed to steel windows by welding. 9.43.2 Fixed to openings /wooden frames with rawl plugs screws etc. 247 9.44 Providing and fixing expanded metal 20x60 mm strands 3.25 mm wide and 1.6 mm thick for windows etc. including 62 x19 mm beading of II nd class teak wood and priming coat with approved steel primer all complete. 248 9.45 Providing and fixing hard drawn steel wire fabric 75x25 mm mesh of weight not less than 7.75 Kg per sqm to window frames etc. including 62x19 mm beading of second class teak wood and priming coat with approved steel primer all complete. 249 9.46 Providing and fixing fly proof galvanized M.S. wire gauge to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.63 mm all complete. 9.46.1 With 2nd class teak wood beading 62x19 mm. 9.46.2 With 12 mm mild steel U beading. 250 9.47 Deduct for fixing 75x25 mm hard drawn steel wire fabric of weight not less than 7.75 Kg. per sqm in panelled and glazed door and window shutter instead of glass sheet 4 mm thick. 251 9.48 Providing 40x5 mm flat (iron hold fast 40 cm long) (0.628 kg) including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embeddings in cement concrete block 30x10x15cm 1:3:6 mix (1 cement : 3 sand : 6 graded stone aggregate 20mm nominal size) 252 9.49 Providing wooden beams including hoisting, fixing in position and applying wood preservative for the unexposed surfaces, etc. complete with : 9.49.1 Sal wood. 9.49.2 Haldu, Kail, Bija wood. 253 9.50 Providing and fixing ISI marked M.S. pressed butt hinges bright finished with necessary screws etc. complete : 9.50.1 125x65x2.12 mm 9.50.2 100x58x1.90 mm 9.50.3 75x47x1.70 mm 9.50.4 50x37x1.50 mm 254 9.51 Providing and fixing IS : 1341 marked M.S. heavy weight butt hinges with necessary screws etc. complete : 9.51.1 125x90x4.00 mm 9.51.2 100x75x3.50 mm 9.51.3 75x60x3.10 mm 9.51.4 50x40x2.50 mm 255 9.52 Providing and fixing ISI marked oxidised M.S. pressed butt hinges with necessary screws etc. complete. 9.52.1 125x65x2.12 mm 9.52.2 100x58x1.90 mm 9.52.3 75x47x1.70 mm 9.52.4 50x37x1.50 mm 256 9.53 Providing and fixing ISI marked oxidised M.S. pressed Parliamentary hinges with necessary screws etc. complete : 9.53.1 150x125x27x2.80 mm 9.53.2 125x125x27x2.80 mm 9.53.3 100x125x27x2.80 mm 9.53.4 75x100x20x2.24 mm 257 9.54 Providing and fixing ISI marked oxidised M.S. single acting spring hinges with necessary screws etc. complete : 9.54.1 150 mm 9.54.2 125 mm 9.54.3 100 mm 258 9.55 Providing and fixing oxidised M.S. double acting spring hinges with necessary screws etc. complete. 9.55.1 150 mm 9.55.2 125 mm 9.55.3 100 mm 259 9.56 Providing M.S. Piano hinges ISI marked IS: 3818 finished with nickel plating and fixing with necessary screws etc., complete. 9.56.1 Overall width 35 mm. 9.56.2 Overall width 50 mm. 9.56.3 Overall width 65 mm. 260 9.57 Providing and fixing ISI marked oxidised M.S. sliding door bolts with nuts and screws etc. complete: 9.57.1 300x16 mm 9.57.2 250x16 mm 261 9.58 Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete : 9.58.1 250x10 mm 9.58.2 200x10 mm 9.58.3 150x10 mm 9.58.4 100x10 mm 262 9.59 Providing and fixing ISI marked 85x42mm oxidised M.S. pull bolt lock conforming to IS: 7534 with necessary screws bolts, nut and washers etc. complete 263 9.60 Providing and fixing ISI marked oxidised M.S. door latches conforming to IS:5930 with screws etc. complete : 9.60.1 300x20x6 mm 9.60.2 250x20x6 mm 264 9.61 Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete : 9.61.1 125 mm 9.61.2 100 mm 9.61.3 75 mm 265 9.62 Providing and fixing oxidised M.S. hasp and staple (safety type) conforming to IS : 363 with necessary screws etc. complete : 9.62.1 150 mm 9.62.2 115 mm 9.62.3 90 mm 266 9.63 Providing and fixing oxidised M.S. casement stays (straight peg type) with necessary screws etc. complete. 9.63.1 300 mm weighing not less than 200 gms. 9.63.2 250 mm weighing not less than 150 gms. 9.63.3 200 mm weighing not less than 120 gms. 267 9.64 Providing and fixing oxidised M.S. Safety chain with necessary fixtures for doors. (Weighing not less than 450 gms.) 268 9.65 Providing and fixing ISI marked stainless steel sliding door bolts with nuts and screws etc. complete: 9.65.1 300x16 mm 9.65.2 250x16 mm 269 9.66 Providing and fixing ISI marked stainless steel tower bolt black finish, (Barrel type) with necessary screws etc. complete : 9.66.1 250x10 mm 9.66.2 200x10 mm 9.66.3 150x10 mm 9.66.4 100x10 mm 270 9.67 Providing and fixing ISI marked 85x42mm stainless steel pull bolt lock with necessary screws bolts, nut and washers etc. complete. 271 9.68 Providing and fixing ISI marked stainless steel door latches with screws etc. complete : 9.68.1 300x20x6 mm 9.68.2 250x20x6 mm 272 9.69 Providing and fixing ISI marked stainless steel handles with necessary screws etc. complete : 9.69.1 125 mm 9.69.2 100 mm 9.69.3 75 mm 273 9.70 Providing and fixing stainless steel hasp and staple (safety type) conforming to IS specification with necessary screws etc. complete : 9.70.1 150 mm 9.70.2 115 mm 9.70.3 90 mm 274 9.71 Providing and fixing stainless steel casement stays (straight peg type) conforming to IS specification with necessary screws etc. complete. 9.71.1 300 mm weighing not less than 200 gms. 9.71.2 250 mm weighing not less than 150 gms. 9.71.3 200 mm weighing not less than 120 gms. 275 9.72 Providing and fixing stainless steel safety chain with necessary fixtures for doors. Conforming to IS specification (Weighing not less than 450 gms.) 276 9.73 Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete : 9.73.1 125x64x1.90 mm 9.73.2 100X58X1.90 mm 9.73.3 75x47x1.80 mm 9.73.4 50x37x1.50 mm 277 9.74 Providing and fixing IS : 12817 marked stainless steel butt hinges (heavy weight) with stainless steel screws etc. complete : 9.74.1 125x64x2.50 mm 9.74.2 100x60x2.50 mm 9.74.3 75x50x2.50 mm 278 9.75 Providing and fixing 50 mm Stainless steel cup board or wardrobe knob with necessary screws (best make of approved quality) 279 9.76 Providing and fixing Stainless steel hanging type floor door stopper with necessary screws, etc. complete. 280 9.77 Providing and fixing bright finished brass butt hinges with necessary screws etc. complete : 9.77.1 125x85x5.5 mm (heavy type) 9.77.2 125x70x4 mm (ordinary type) 9.77.3 100x85x5.5 mm (heavy type) 9.77.4 100x70x4 mm (ordinary type) 9.77.5 75x65x4 mm (heavy type) 9.77.6 75x40x2.5 mm (ordinary type) 9.77.7 50x40x2.5 mm (ordinary type) 281 9.78 Providing and fixing bright finished brass parliamentary hinges with necessary screws etc. complete : 9.78.1 150x125x27x5 mm 9.78.2 125x125x27x5 mm 9.78.3 100x125x27x5 mm 9.78.4 75x100x20x3.2 mm 282 9.79 Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete : 9.79.1 400x10 mm 9.79.2 250x10 mm 9.79.3 200x10 mm 9.79.4 150x10 mm 9.79.5 100x10 mm 283 9.80 Providing and fixing bright finished brass door latch with necessary screws etc. complete. 9.80.1 300x16x5 mm 9.80.2 250x16x5 mm 284 9.81 Providing and fixing bright finished brass handles with necessary screws etc. complete. 9.81.1 125 mm 9.81.2 100 mm 9.81.3 75 mm 285 9.82 Providing and fixing bright finished brass sliding door bolts with nuts and screws etc complete. 9.82.1 300x16mm 9.82.2 250x16mm 286 9.83 Providing and fixing bright finished brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles with necessary screws etc. complete (best make of approved quality). 287 9.84 Providing and fixing bright finished brass 100 mm mortice latch and lock ISI marked with six levers and a pair of anodised (anodic coating not less than grade AC 10 as per IS : 1868) aluminium lever handles with necessary screws etc. complete (Best make of approved quality). 288 9.85 Providing and fixing bright finished brass 100 mm mortice latch with one dead bolt and a pair of lever handles with necessary screws etc. complete (best make of approved quality). 289 9.86 Providing and fixing bright finished brass night latch including necessary screws etc. complete (best make of approved quality). 290 9.87 Providing and fixing special quality bright finished brass cupboard or wardrobe locks with four levers including necessary screws etc. complete (best make of approved quality) : 9.87.1 40 mm 9.87.2 50 mm 9.87.3 65 mm 9.87.4 75 mm 291 9.88 Providing and fixing 50 mm bright finished brass cup board or wardrobe knob with necessary screws (best make of approved quality) 292 9.89 Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete. 293 9.90 Providing and fixing bright finished brass casement window fastener with necessary screws etc. complete. 294 9.91 Providing and fixing bright finished brass casement stays (straight peg type) with necessary screws etc. complete : 9.91.1 300 mm weighing not less than 330 gms 9.91.2 250 mm weighing not less than 280 gms 9.91.3 200 mm weighing not less than 240 gms 295 9.92 Providing and fixing bright finished brass hasp and staple (safety type) with necessary screws etc. complete: 9.92.1 150 mm 9.92.2 115 mm 9.92.3 90 mm 296 9.93 Providing and fixing Cromium plated brass hanging type floor door stopper with necessary screws, etc. complete. 297 9.94 Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm) with necessary accessories and screws etc. complete. 298 9.95 Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm) with double speed adjustment with necessary accessories and screws etc. complete. 299 9.96 Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles with necessary screws etc. complete (best make of approved quality). 300 9.97 Providing and fixing chromium plated brass 100 mm mortice latch with one dead bolt and a pair of lever handles with necessary screws etc. complete (best make of approved quality). 301 9.98 Providing and fixing chromium plated brass night latch including necessary screws etc. complete (Best make of approved quality). 302 9.99 Providing and fixing special quality chromium plated brass cupboard locks with six levers including necessary screws etc. complete (Best make of approved quality) of : 9.99.1 Size 40 mm 9.99.2 Size 50 mm 9.99.3 Size 65 mm 9.99.4 Size 75 mm 303 9.100 Providing and fixing chromium plated brass 50 mm cupboard or wardrobe knobs with nuts complete. 304 9.101 Providing and fixing chromium plated brass sliding door bolts ISI marked with nuts and screws etc complete. 9.101.1 300x16mm 9.101.2 250x16mm 305 9.102 Providing and fixing chromium plated brass tower bolts ISI marked with nuts and screws etc complete. 9.102.1 400X10mm 9.102.2 300x10mm 9.102.3 250x10mm 9.102.4 200x10 mm 9.102.5 150x10 mm 9.102.6 100x10 mm 306 9.103 Providing and fixing chromium plated brass door latch ISI marked with necessary screws etc complete. 9.103.1 300x16x5mm 9.103.2 250x16x5mm 307 9.104 Providing and fixing chromium plated brass night latch ISI marked with necessary screws etc complete. 308 9.105 Providing and fixing chromium plated brass handles with necessary screws etc. complete: 9.105.1 125 mm 9.105.2 100 mm 9.105.3 75 mm 309 9.106 Providing and fixing chromium plated brass casement window fastener with necessary screws etc. complete. 310 9.107 Providing and fixing chromium plated brass casement stays (straight peg type) with necessary screws etc. complete : 9.107.1 300 mm weighing not less than 330 gms 9.107.2 250 mm weighing not less than 280 gms 9.107.3 200 mm weighing not less than 240 gms 311 9.108 Providing and fixing ISI marked aluminium butt hinges anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade with necessary screws etc. complete: Note:- Aluminum hinges shall not be used in wooden shutters. 9.108.1 125x75x4 mm 9.108.2 125x63x4 mm 9.108.3 100x75x4 mm 9.108.4 100x63x4 mm 9.108.5 100x63x3.2 mm 9.108.6 75x63x4 mm 9.108.7 75x63x3.2 mm 9.108.8 75x45x3.2 mm 312 9.109 Providing and fixing aluminium sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete: 9.109.1 300x16 mm 9.109.2 250x16 mm 313 9.110 Providing and fixing aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete: 9.110.1 400X10mm 9.110.2 300x10 mm 9.110.3 250x10 mm 9.110.4 200x10 mm 9.110.5 150x10 mm 9.110.6 100x10 mm 314 9.111 Providing and fixing aluminium pull bolt lock anodised ISI marked (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade with necessary screws bolts, nut and washers etc. complete. 315 9.112 Providing and fixing 50cm long aluminium kicking plate 100x3.15 mm anodised (anodic coating not less than grade AC 10 as per IS :1868) transparent or dyed to required colour or shade with necessary screws etc. complete. 316 9.113 Providing and fixing aluminium handles ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete: 9.113.1 125 mm 9.113.2 100 mm 9.113.3 75 mm 317 9.114 Providing and fixing aluminium hanging floor door stopper ISI marked anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade with necessary screws etc. complete. 9.114.1 Single rubber stopper 9.114.2 Twin rubber stopper 318 9.115 Providing and fixing aluminium casement window stays ISI marked anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade with necessary screws etc. complete. 319 9.116 Providing and fixing aluminium tee channels (heavy duty) with rollers, stop end in pelmets as curtain rod. 320 9.117 Providing and fixing aluminum U beading of required size to Pre-laminated /flush door shutter including fixing etc. complete as per direction of Engineer-in-charge. 321 9.118 Providing and fixing PTMT handles with necessary screws etc. complete. 9.118.1 125x34x24 mm weighing not less than 23 gms. 9.118.2 150x34x24 mm weighing not less than 26 gms. 322 9.119 Providing and fixing PTMT Butt hinges with necessary screws etc. complete. 9.119.1 75x60x10 mm fitted with 5.5 mm dia M.S. Bright Bar Rod weighing not less than 34 gms. 9.119.2 100x75x10 mm fitted with 5.5 mm dia MS Bright Bar Rod weighing not less than 53 gms. 323 9.120 Providing and fixing PTMT Tower Bolts with 12 mm one piece rod inside and necessary screws etc., complete. 9.120.1 152x42x18 mm weighing not less than 60 gms. 9.120.2 202x42x18 mm weighing not less than 78 gms. 324 9.121 Providing and fixing PTMT door catcher of length 72 mm and dia. of 42 mm with suitable washers weighing not less than 33 gms. 325 9.122 Providing and fixing PTMT hanging type floor door stoper with necessary screws etc complete. 326 9.123 Providing and fixing wire gauge shutters using stainless steel grade 304 wire gauge with wire of dia 0.5 mm and average width of aperture 1.4 mm in both directions for doors, windows and clerestory windows with necessary screws: 9.123.1 35 mm thick shutters with ISI marked M.S. pressed butt hinges bright finished of required size. 9.123.1.1 Second class teak wood. 9.123.1.2 Kiln seasoned and chemically treated Haldu, Kail, Bija wood. 9.123.1.3 Kiln seasoned selected class of sheesham wood. 9.123.2 35 mm thick shutters with ISI marked stainless steel butt hinges of required size. 9.123.2.1 Second class teak wood. 9.123.2.2 Kiln seasoned and chemically treated Haldu, Kail, Bija wood. 9.123.2.3 Kiln seasoned selected class of sheesham wood. 9.123.3 30 mm thick shutters with ISI marked M.S. pressed butt hinges bright finished of required size. 9.123.3.1 Second class teak wood. 9.123.3.2 Kiln seasoned and chemically treated Haldu, Kail, Bija wood. 9.123.3.3 Kiln seasoned selected class of sheesham wood. 9.123.4 30 mm thick shutters with ISI marked stainless steel butt hinges of required size. 9.123.4.1 Second class teak wood. 9.123.4.2 Kiln seasoned and chemically treated Haldu, Kail, Bija wood. 9.123.4.3 Kiln seasoned selected class of sheesham wood. 327 9.124 Providing and fixing fly proof stainless steel grade 304 wire gauge, to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.50 mm all complete. 9.124.1 With 2nd class teak wood beading 62x19 mm. 9.124.2 With 12 mm mild steel U beading. 328 9.125 Providing and fixing Bamboo jaffery/ fencing consisting of superior quality 25mm dia (Average) half cut bamboo placed vertically and fixed together with three numbers horizontal running members of Haldu, Kail, Bija wood in scantling of section 50x25mm fixed with nails and G.I wire on existing support complete as per direction of Engineer-in-charge. 329 9.126 Providing and fixing wooden moulded corner beading of triangular shape to the junction of panelling etc. with iron screws, plugs and priming coat on unexposed surface etc. complete 2nd class teak wood. 50x50mm (base and height). 330 9.127 Providing and fixing 2nd class teak wood lipping/ moulded beading or Taj beading of size 18x5mm fixed with wooden adhesive of approved quality and screws/ nails on the edges of the Pre-laminated particle board as per direction of Engineer- in-charge. 331 9.128 Providing and fixing bright finished 100mm mortice lock with 6 levers without pair of handles for aluminium door with necessary screws etc complete (Best make of approved quality) as per direction of Engineer-in-charge. 332 9.129 Providing and fixing magnetic catcher in cupboard / ward robe shutters including fixing with necessary screws etc. complete (Best make of approved quality). 9.129.1 Triple strip vertical type. 9.129.2 Double strip (horizontal type). 333 9.130 Providing and fixing magic eye in door shutters including fixing. Complete (Best make of approved quality). 334 9.131 Providing and fixing powder coated telescopic drawer channels with necessary screws etc. complete as per directions of Engineer-in-charge. 9.131.1 300mm long 9.131.2 450mm long 9.131.3 500mm long 335 9.132 Providing and fixing sliding arrangement in racks/ cupboards/cabinets shutter by P/F stainless steel rollers to run inside C or E aluminium channel section (The payment of C or E channel shall be made separately) 336 9.133 Providing and fixing 12mm thick panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25mm to 40mm thick. 9.133.1 Marine plywood conforming to IS: 710 9.133.2 Fire retardant plywood conforming to IS: 5509. 337 9.134 Providing and Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt / suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S including cost of adhesive of approved quality. 9.134.1 1.5 mm thick. 9.134.2 1.0 mm thick. 338 9.135 Providing and fixing cup board shutters 25mm thick, with Pre-laminated flat pressed three layer particle board or graded wood particle board IS: 12823 marked exterior grade (Grade l Type ll) having one side decorative lamination and other side balancing lamination including IInd class teak wood lipping of 25mm wide x12 mm thick with necessary screws and bright finished stainless steel piano hinges complete as per direction of the Engineer-in-Charge. 339 9.136 Providing and fixing cup board shutters with 25mm thick veneered particle board IS : 3097 marked exterior grade (Grade I) of approved make including IInd class teak wood lipping of 25mm wide x 12 mm thick with necessary screws and bright finished stainless steel piano hinges complete as per direction of Engineer-in- Charge. 9.136.1 With decorative veneering on one side and commercial veneering on other side. 9.136.2 With non decorative veneering on both sides. 340 9.137 Providing and fixing factory made shutters of 25 mm thick Pre-laminated particle board flat pressed three layer or graded wood particle board with one side decorative finish and other side balancing lamination conforming to IS: 12823 Grade l Type ll, of approved design, and edges sealed with water resistant paint and lipped with aluminium U type edge beading all- round the shutter, including fixing with angle cleat, grip strip, cadmium plated steel screws including fixing of aluminium hinges 100x63x4 mm etc. complete as per architectural drawing and direction of Engineer-in-Charge (Cost of U beading and hinges will be paid for separately). 341 9.138 Providing and fixing in wall lining MDF board medium density fibre board IS: 14587:1998 marked, Pre-laminated one side decorative lamination and other side balancing lamination, with necessary fixing arrangement and screws etc. complete. 9.138.1 12 mm thick. 9.138.2 18 mm thick. 9.138.3 25 mm thick. 342 9.139 Providing and fixing 25mm thick pre- laminated medium density fibre board exterior grade(Grade-I) IS:14587:1998 marked one side decorative to be sealed with PVC edge bending tape 2.00 mm thick of approved brand including ISI marked nickeled plated bright finishing M.S. piano hinges IS:3818 marked with necessary screwed complete 343 9.140 Providing and fixing skirting with Pre- laminated medium density fibre board exterior grade (Grade-I) IS: 14587:1998 marked, with necessary fixing arrangements and screws, including drilling necessary holes for rawl plugs etc. and edges to be sealed with PVC edge bending tape 2.00 mm thick of approved brand complete. 9.140.1 18 mm thick 9.140.2 25 mm thick 344 9.141 Providing and fixing partition upto ceiling height consisting of G.I. frame and required board including providing and fixing of frame work made of special section power pressed/ roll form G.I. sheet to be provided at the horizontal joints of two boards, fixed to the studs using metal to metal flat head screws, including jointing and finishing to a flush finish with recommended jointing compound, jointing tape, angle beads at corner (25 mm x 25 mm x 0.5 mm), joint finisher and two coats of primer suitable for board as per manufactures specification and direction of engineer in charge all complete. 9.141.1 75mm overall thickness partition with 12.5 mm thick double skin fire rated glass reinforced gypsum (GRG) plaster board conforming to IS: 2095: part 3 1996 Board with BIS certification marks. 9.141.2 75mm overall thickness partition with 12.5 mm thick double skin tapered edged plain Gypsum plaster board conforming to IS:2095: part I 1996 Board with BIS certification marks. 9.141.3 66mm overall thickness Partition with 8mm thick double skin Calcium Silicate Board made with Calcareous and Siliceous materials reinforced with cellulose fiber manufactured through autoclaving process with Compressive Strength 225 kg/sq.cm, Bending Strength 100 kg./sq.cm. 9.141.4 66mm overall thickness partition using 8mm thick double skin non- asbestos multipurpose cement board reinforced with cellulose fibre manufactured through autoclaving process (High pressure steam cured) as per IS: 14862 with suitable fibre cement screw. 9.141.5 68mm overall thickness partition using 9mm thick Heavy Duty Fibre Cement Board double skin non asbestos, reinforced with cellulose fibre,manufactured through autoclaving proces(High presssure steam cured)Type A, Category 4 conforming to IS 14862:2000. (for wet areas) 9.141.6 70 mm overall thickness Partition using 10mm thick double skin non-asbestost multipurpose termite, fire & moisure resistance (acoustic 30db) cement bonded particle board as per IS: 14276 with suitable cement bonded board screw. 345 9.142 Providing and fixing, in position concealed G.I. section for wall paneling using board of required thickness fixed on the W profile (0.55mm thick ) having a knurled web of 51.55mm and two flanges of 26mm each with lips of 10.55 mm, placed @ 610mm C/C with fully threaded self- tapping dry wall screws. Board is fixed to the W profile with 25 mm countersunk ribbed head screws @ 200mm C/C., all complete as per the drawing and directions of engineer-in-charge the joints of the boards are finished with specially formulated jointing compound and 48mm wide jointing tape to provide seamless finish. 9.142.1 10 mm thick tapered edge calcium silicate board made with calcareous and siliceous materials reinforced with cellulose fibre manufactured through autoclaving process to give stable crystalline structure, with compressive strength 225 kg/sq.cm, Bending strength 100 kg/sq.cm. 9.142.2 12 mm thick Gypsum board conforming to IS: 2095 Part-I. 9.142.3 8 mm thick non-asbestost multipurpose termite, fire & moisure resistance cement bonded particle board as per IS: 14276 with suitable cement bonded board screw. 9.142.4 8mm Both side Factory Prelamianted cement bonded particle board as per IS: 15786. 9.142.5 9mm thick non asbestos,heavy duty fibre cement board reinforced with cellulose fibre manufactured through autoclaving process(High pressure steam cured) Type A,Category 4, conforming to IS 14862. 346 9.143 Providing and fixing frame work for partitions/ wall lining etc. made of 50x50x1.6mm hollow MS tube, placed along the walls, ceiling and floor in a grid pattern with spacing @ 60 cm centre to centre both ways (vertically and horizontally ) including making provision for opening for doors, windows, electrical conduits, switch boards etc., including providing with two coats of approved steel primer etc. complete, all as per direction of Engineer- in-charge. 347 9.144 Providing and fixing panelling or paneling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (area of opening for panel inserts excluding portion inside grooves or rebated to be measured). Panelling for panelled and glazed shutters 25mm to 40mm thick: Pre-laminated with decorative lamination on both side exterior Grade - I MDF Board 12 mm thick confirming to IS:14587 348 9.145 Providing and fixing Pre -laminated medium density fibre board exterior grade (Grade-I) IS: 14587:1998 marked, to frame, backing or studding with screws etc. complete (Frames, backing or studding to be paid separately). 9.145.1 Board 12 mm thick 9.145.2 Board 18 mm thick 349 9.146 Providing and fixing Pre-laminated medium density fibre board IS: 14587:1998 marked, with one side decorative lamination other side balancing lamination Grade-I(exterior grade) in shelves with screws and fittings wherever required, edges to be sealed with PVC edge bending tape 2.00 mm thick of approved brand (fittings to be paid separately). 9.146.1 18 mm thick 9.146.2 25 mm thick 350 9.147 Providing and Installation of acoustical wall panelling fabric finish hardened square edge, FR grade fabric (colour as approved by Egnineer in charge) wrapped soft fibre core (glass fibre) panel having metal framing, of size 600x2100x25mm having density 100-120Kgs/ m3, weight 3.0kg/m2 NRC up to 0.9 installed by using impaling clip. Impaling clips are attached directly to the wall/frame work with the points extending outward. Then panels shall positioned and pressed into place. 351 9.148 Providing and installation of acoustical wall panelling wood finish Slats made out of HDF board , Melamine / veneer laminated finish, perforated wooden grooved slats (2mm grooves @ 8mm centers) / (2mm Slats @16mm pitch) / (2mm grooves @ 32mm centers) / (2mm grooves @ 64mm centers), Aluminium core cross channel having thickness 0.5mm, length 2400mm, web 15mm and 27mm, depth 18mm and flanges of 7mm with suitable edge and centre brackets is then fixed perpendicular to the cross channel with the help of fasteners at every 400mm centers. Contractor to Provide expansion joints of 3mm at every 5mts bothways. 352 9.149 Providing and installation of paintble acoustic wall panelling consisting of strand kerfed edge paint finished as approved by Engineer in charge. magnesite bonded wood fiber panels of size 600x2400x20mm having density 400kg/m3, weight 8- 20kg/m2 which is fixed to GI strut system. fastened to wall positioned horizontally in a regular manner at 600mm centers. PVC Vinyl core UV treated H-Spline having thickness 2mm and length 2400mm to be fixed perpendicular to the Cross channel at 600mm centers. The Kerfed edge panels shall be then inserted into the H-spline against wall to perfect fit. 9.149.1 Wt. 8.20 kg/m2 9.149.2 Wt. 4.2 kg/m2 353 9.150 Providing and fixing plain lining with necessary screws/nuts and bolts/ nails including a coat of approved primer on one face and fixed on wooden /steel frame work complete as per direction of Engineer-incharge. (Frame work shall be paid forseparately) 9.150.1 12mm thick commercial ply conforming to IS: 1328 BWR type. 9.150.2 18mm thick commercial ply conforming to IS: 1328 BWR type. 354 9.151 Providing and Installation of acoustic wall panelling consisting of Soak Coard of selected colours as approved by Engineer in charge. Kerf edge Fabric wrapped wood fiber panels of size 600x2400x20mm having density 400Kgs/m3, weight 4- 20kg/m2 installed by using GI strut system. PVC Vinyl core UV treated H-Spline having thickness 2mm and length 2400mm to be fixed perpendicular to the Cross channels at 600mm centers. Kerfed edge Fabric wrapped panels shall be then inserted into the H-spline against wall to perfect fit. 355 9.152 Providing and Installation of acoustic wall panelling consisting of Soak Cord of selected colours as approved by Engineer in charge, square edge Fabric wrapped wood fiber panels of size 600x1200x10mm having density 400Kgs/m3, weight 4- 20kg/m2 installed by using GI struts,Z bars. GI Z bars having 40mm height, thickness 1.2mm is first fixed behind the panels by identifying resin spots by using suitable fasteners.Clean exposed surfaces of wall and ensure walls are in plumb line before installing on wall (provide necessary packing shims if required). Soak cord square edge panels shall be slided into the Z bars fixed on wall. 356 9.153 Providing and installation of acoustic wall panelling consisting of Stretch NRC by using FR Grade NRC fabric of size 1700mm width, shall be stretched by using wooden base 10mm thick, rigid vinyl Stretch Tracks half wrap/ full wrap 25mm and Midseam 300mm centers. The fabric is stuck on the Align Tape (by removing the protective cover) at the same time as being stretched and tucked into the Stretch tracks and secure into the locking jaws so that it will be smooth, free of wrinkles with the tucking tools. Note -minimum 50mm additional fabric is required for tucking hence maximum module width would be 1600mm. 357 9.154 Providing and Installation of wall panelling consisting of Square edge Magnesia core panels of size 1100x2400x8mmmm having density 1000kgs/m3, weight 8kg/m2 installed by using GI Strut system. The GI struct system includes Cross channel having thickness 0.45mm, length 3600mm, knurled web 40, depth 10mm and equal flanges of 15mm is fastened to wall positioned horizontally in a regular manner at 600mm c/c. The panels to be fixed on the cross channel with suitable fasteners. 358 9.155 Supplying and installation of magnesia block 66 mm thick drywall partition including Framework includes Floor/ Head GI channels having thickness 0.5mm, length 3600mm, equal flanges of 32mm and web of 50mm fixed to floor and ceiling with suitable fasteners at 300mm centers staggered. Second layer of magenesia oxide block 8mm thick should be fixed other side of the frame work similar fashion as the first layer. 3mm gap should be maintained between boards.3 mm gap shall be filled with jointing compound. Magnesia oxide block shall have following physical charecterstics. 9.155.1 Using 8mm thick magnesia block 9.155.2 Using10mm thick magnesia block 9.155.3 Using12mm thick magnesia block 9.155.4 Using12mm thick magnesia block 359 9.156 Add extra for providing and fixing Thermal insulation by providing 50mm thick synth PF having dencity 1000 GSM within the cavity held in position by using chicken wire mesh/ cross bracing/ pasting to the wall. 360 9.157 Providing and laying Gypsum panel partitions 100mm thick with water proof Gypsum panels of size 666x500x100mm, made of calcite phosphor Gypsum fixed with tongue and groove, jointed with bonding plaster as per manufacturers specifications in superstructure above plinth level up to floor II level. Gypsum blocks will have a minimum compressive strength of 9.3 kg/cm2. 361 9.158 Providing and fixing factory made UPVC door frame made of UPVC extruded sections having an overall dimension as below (tolerance ±1mm), with wall thickness 2.0 mm (± 0.2mm), corners of the door frame to be Jointed with galvanized brackets and stainless steel screws, joints mitred and Plastic welded. The hinge side vertical of the frame reinforced by galvanized M.S. tube of size 19 X 19mm and 1mm (± 0.1 mm) wall thickness and 3 nos. stainless steel hinges fixed to the frame complete as per manufacturers specification and direction of Engineer-in-charge: 9.158.1 Extruded section Profile size 48x40 mm. 9.158.2 Extruded section Profile size 42x50 mm. 362 9.159 Providing and fixing Panelled UPVC door shutter to existing door frames. 24 mm thick factory made UPVC door shutters made of styles and rails of a UPVC hollow section of size 59x24 mm and wall thickness 2 mm (± 0.2 mm) with inbuilt edging on both sides. The panels filled vertically and tie bar at two places by inserting horizontally 6 mm galvanised M.S. rod and fastened with nuts and washers, complete as per manufacturers specification and direction of Engineer-in-charge. (For W.C. and bathroom door shutter). 363 9.160 Providing and fixing UPVC panelled door shutter UPVC 30 mm thick factory made PVC or UPVC door shutter made of styles and rails of a UPVC hollow section of size 60x30 mm and wall thickness 2 mm (± 0.2 mm), The panels filled vertically and tie bar at two places by inserting horizontally 6 mm galvanised M.S. rod and fastened with nuts and washers, complete as per manufacturers specification and direction of Engineer-in-charge. 364 9.161 Providing and fixing 25mm thick PVC flush door shutters made out of a one piece Multi chamber extruded PVC section of the size of 762mmx25mm or less as per requirement with an average wall thickness of 1mm (± 0.3mm). PVC foam end cap of size 23x10mm are provided on both vertical edges to ensure the overall thickness of 25mm. The Top and Bottom edges of the shutter are covered with an end-cap of the size 25mmx11mm. Door shutter shall be reinforced with special polymeric reinforcements as per required specification and direction of Engineer-in- charge to take up necessary hardware and fixtures. Stickers indicating the locations of hardware will be pasted at appropriate places. 365 9.162 Providing and fixing 37 mm thick factory made PVC door shutter, styles and rails made of PVC hollow section of size 100mmx37mm with wall thickness 2mm (±0.2mm), with inbuilt bead on one side, styles and rails mitered cut and joint at the corners by means of 2 nos. of plastic brackets of size 100mmx37mm, wall thickness 2mm (+0.2mm) will be fixed to the vertical styles. Providing with PVC snapfit beads and panel of size 100mmx20 mm, and inserting 2 nos. tie bar of 6 mm dia and fastening with nuts and washers complete, all as per manufacturers specification and direction of Engineer-in-charge. 366 9.163 Providing and Fixing, factory made, PVC door frame made of PVC extruded sections of size 75mmx53 mm, having wall thickness 2.0mm (±0.2mm). Both verticals sides of the frame reinforced with PVC profile of cross section size 28mm x 30mm x2mm thickness (± 0.2 mm) and 75mmx200 mm long, including reinforcing both ends of the top frame with PVC profile. PVC Door Frame and PVC reinforcement profile to be mitred cut jointed and fusion welded together, including providing and fixing 3 nos. of 125mm long stainless steel hinges to frame, fixing the frame with jamb with required nos. and sizes of anchor dash fastener, all complete as per manufacturers specification and direction of engineer-in-charge. 367 9.164 Providing and fixing 37 mm thick factory made PVC Door shutter, styles and rails made of PVC hollow extruded printed and laminated section having overall dimension 115mm x 37mm with wall thickness , panels of 100 x 20 mm printed and laminated and inserting 2 nos. 6 mm dia. bright steel rod horizontally with both side threaded and tightened with check nuts and washers complete, all as per manufacturers specification and direction of Engineer-in-Charge. 368 9.165 Providing and fixing factory made P.V.C. door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet, mitred at corners and joined with 2 Nos. of 150mm long brackets of 15x15mm M.S. square tube, the vertical door frame profiles to be reinforced with 19x19mm M.S. square tube of 19 gauge, EPDM rubber gasket weather seal to be provided through out the frame. The door frame to be fixed to the wall using M.S. screws of 65/100mm size, complete as per manufacturers specification and direction of Engineer-in- Charge. 369 9.166 Providing and fixing factory made 30 mm thick PVC door shutter consisting of frame made out of M.S. tubes of 19 gauge thickness and size of 19mm x 19mm for styles and 15x15mm for top and bottom rails. M.S. frame shall have a coat of steel primers and joined together with solvent cement adhesive. An additional 5mm thick PVC strip of 20mm width is to be stuck on the interior side of the C Channel using PVC solvent adhesive etc. complete as per direction of Engineer-in-charge. Manufacturer’s specification and drawing. 9.166.1 Plain PVC door shutters. 9.166.2 Pre laminated PVC door shutters. 370 9.167 Providing and fixing factory made door frame (single rebate) made out of single piece extruded solid PVC foam profile with homogenous fine cellular structure having smooth outer integral skin having 62 mm width and 32 mm thickness, frame will be mitred and Jointed with self driven self tapping screws of size 38 mm x 4 mm and PVC solvent cement, including fixing the frame to wall with suitable dia and length anchor fastener as per manufacturer’s specification and direction of Engineer-in-charge. 371 9.168 Providing and fixing factory made 30 mm thick door shutter made of solid PVC foam profile. The styles and rails shall be of size 75 mmx30 mm having wall thickness 5 mm. The styles, top and bottom rails shall have one side wall thickness of 15 mm integrally extruded in the middle of the lock rail and fixed with styles with the help of PVC solvent cement and self driven self tapping screws of size 100 mmx8 mm complete as per manufacturers specifications and direction of Engineer-in-charge: 9.168.1 Non decorative finish. 9.168.2 Decorative finish (both side wood grained finish). 372 9.169 Providing and fixing factory made single extruded WPC(Wood Polymer Composite) solid door/window/ceosetory windows and other frames/chowkhat comprising of virgin polymer of K value 58-60 of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S. hold fast/lugs/S.S.dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/lugs or S.S. dash fasteners shall be paid separately) 9.169.1 Single rebate (75 mm X 50 mm) 9.169.2 Single rebate (100 mm X50 mm) 9.169.3 Single or double rebate (125 mm X 65 mm) 373 9.170 Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice .husk/wheat husk) and non toxic additives property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-InCharge. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately) 9.170.1 24 mm thick WPC (Wood polymer composite) solid plain flush door shutter 9.170.2 28 mm thick WPC (Wood polymer composite) solid plain flush door shutter 9.170.3 30 mm thick WPC (Wood polymer composite) solid plain flush door shutter 9.170.4 35 mm thick WPC (Wood polymer composite) solid plain flush door shutter 374 9.171 Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of required size comprising of virgin polymer of K value 58-60 of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-InCharge. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately). 9.171.1 30 mm thick WPC (Wood Polymer Composite) solid decorative type flush door shutter 9.171.2 35 mm thick WPC (Wood Polymer Composite) solid decorative type flush door shutter 375 9.172 Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid board one side white colour and other side of board laminated with PVC foil of minimum 14 micron thickness of approved design pasted with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel piano hinges/soft close clip on concealed hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In-Charge. (Note: stainless steel piano hinges/soft close clip on concealed hinges and necessary S.S screws shall be paid separately) 9.172.1 18 mm thick 9.172.2 25 mm thick 376 9.173 Providing and fixing factory made single extruded WPC (Wood polymer composite solid plain white color board for backing of cupboards and bathrooms/ kitchen cabinets etc. of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel screws etc. all as per direction of Engineer-in-Charge. (Note: stainless steel screws shall be paid separately) 9.173.1 6 mm thick 9.173.2 12 mm thick 377 9.174 Providing and fixing factory made 18 mm thick single extruded WPC (Wood Polymer Composite) solid plain white colour board Jali CNC (Computer numeric control) routed of approved design by Engineer-in -charge which are machine cut for duct/shaft covering, partitions and facades comprising of virgin polymer of K value 58-60 of approved steel primer, placed at grid made at 1.0 x 1.0 m or as per requirement at site with necessary stainless steel fasteners and SS screws etc., all complete as per direction of Engineer-In-Charge. (Note: M.S (mild steel) framework with priming coat and necessary SS fasteners and SS screws shall be paid separately. 378 9.175 Providing and fixing PVC Door Frame of size 50x47mm with a wall thickness of 5 mm (±0.2 mm) made out of single piece extruded PVC profile, with mitred cut joints and joint with 2nos of PVC bracket of size 40x20mm M.S. rectangular tube of 0.8 mm , including providing EPDM rubber gasket weather seal throughout the frame, including jointing 5mm PVC frame strip with PVC solvent cement on the back of the profile. The door frame to be fixed to the wall using 8x100mm long anchor fasteners complete, all as per manufacturer’s specification and direction of Engineer -in- charge. 379 9.176 35 mm thick factory made Solid panel PVC Door shutter made out of single piece extruded soild PVC profiles, 5mm (±0.2mm) thick, having styles and rails (except lock rail) of size 95 mmx 35 mm x 5 mm, out of which 75 mm shall be flat and 20 mm shall be tapered (on both side), having one side thickness of 15 mm solid core in middle of rail section integrally extruded, fixing the styles and rails with the help of solvent and self driven self tapping screws of 125 mm x11 mm, including providing 5mm Single piece solid PVC extruded sheet inserted in the door as panel, all complete as per manufacturers specification and direction of Engineer-in- charge. 9.176.1 Non decorative finish (matt finish). 9.176.2 Decorative finish (wood grained finish). 380 9.177 Providing and fixing PVC rigid foam sheet 1mm thick on existing door shutters (bathroom and W.C. doors) using synthetic rubber based adhesive. 381 9.178 Providing and fixing Fibre Glass Reinforced plastic (FRP) Door Frames of cross-section 90mm x 45mm having single rebate of 32mmx15mm to receive shutter of 30mm thickness .The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat .Doorframe laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fibreglass from all sides. MS stat shall be provided 382 9.179 Providing and fixing to existing door frames. 30 mm thick glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5mm thick FRP laminate for panels conforming to IS: 14856 including fixing to frames. 383 9.180 Providing and fixing door frame FRP 30mm thick fiberglass reinforced Plastic (F.R.P.) flush door shutter in different plain and wood inish made with fire retardant grade unsaturated polyurethane foam (PUF)/Polystyrene foam to be used as filler material throughout the hollow panel, casted monolithically with testing parameters of F.R.P. laminate conforming to table - 3 of IS: 14856, complete as per direction of Engineer-in-charge. 384 9.181 Providing and fixing factory made Fibreglass Reinforced plastics (F.R.P.) chajja 4mm thick of required colour, size and design made by Resin Transfer Moulding (RTM) FRP Chajja should be manufactured using unsaturated Polyester resin as per IS: 6746 duly reinforced with fibre glass chopped strand mat (CSM) as per IS: 11551 complete with protective Gel coat U/V coating on Top for complete resistance from the extreme of temperature, weather and sunlight. 385 9.182 Providing and fixing fire resistant door frame of section 143x57 mm having built in rebate made out of 16 SWG G.I.sheet (zinc coating not less than 120 gm/sqm) duly filled with vermuculite based of size 10x4 mm (minimum) alround the frame and fixing with dash fastener of approved size and make, including applying a coat of approved brand fire resistant primer etc. complete as per direction of Engineer-in- charge (Dash fastener to be paid for separately). 386 9.183 Providing and fixing 50 mm thick glazed fire resistant door shutters of 60 minutes fire rating conforming to IS:3614 (Part-II) tested and certified as per laboratory approved by Engineer-in-charge with suitable mounting on door frame, consisting of vertical styles, lock rail, top rail 100mm wide, bottom rail 200mm wide, made out of 16 SWG G.I.sheet (zinc coating not less than 120 gm/m2) duly filled FR insulation material and fixing with necessary stainless steel ball bearing hinges of approved make, including applying a coat of approved fire resistant primer etc. all complete as per direction of Engineer-in-charge (panneling to be paid for separately). 387 9.184 Providing and fixing glazing in fire resistant door shutters, fixed panels, ventilators and partitions etc., with G.I. beading of appropriate size made out of 20 SWG G.I.sheet (zinc coating not less than 120 gm/m2), fire resistant sealant, including applying a coat of approved fire resistant primer on G.I. beading etc. complete all as per direction of Engineer- in-charge. With clear fire resistant glass panes 6mm thick of approved brand, having minimum 60 minutes fire resistance. 388 9.185 Providing and fixing panic bar / latch (Double point) fitted with a single body, Trim Latch and Lock on back side of the Panic Latch of reputed brand and manufacture to be approved by the Engineer- in- charge, all complete. 389 9.186 Providing and Fixing factory made UPVC door frame made of UPVC exturded sections, of size 65 mmx55 mm with wall thickness 2.0 mm (±0.2 mm), corners of the door frame to be mitred cut and jointed with plastic brackets and stainless steel screws, reinforcing hinge side vertical of the frames with PVC profile of Size 28 mmx30 mm having wall thickness 2 mm (±0.2mm), including providing and fixing 3 nos. of 125 mm long stainless steel hinges to the frame, fixing the frame with jamb with required number and size of anchor dash fastners, all complete as per manufacturers specification and direction of Engineer-in-charge. 390 9.187 Providing and Fixing, UPVC factory made, white colour casement/sliding window and door made of extruded profiles. Profiles of frames and sash will be mitered cut and fusion welded at all corners including drilling of holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware, EPDM gasket, 1.2 ± 0.2mm thick galvanised steel profile to be inserted in required profile, frame will be fixed to the wall with 8 mmx100 mm long fasteners, all complete as per direction of Engineer-in-charge. (Glazing, hardware hinges and fitting etc. to be paid separately.) 9.187.1 Casement Window (Outward/Inward opening) with hinge System. 9.187.1.1 Frame (50 mm x 50mm) 9.187.1.2 Sash (Style and Rail) (62 mm x 34 mm) 9.187.1.3 Mullion (intermediate Section) (66mm x 50 mm) 9.187.1.4 ‘T Profile (one vertical length in between two shutters) (24mm x 34.5mm) 9.187.1.5 Glazing bead (12mm x 18mm) 9.187.2 Casement Window (With friction hinge and outward opening) 9.187.2.1 Casement Frame (67mm x 62mm) 9.187.2.2 Casement Window Sash/Mullion (67mm x75mm) (style, rail and intermediate section) 9.187.2.3 Casement Glazing bead (35mm x 18 mm) 9.187.3 Sliding Window (Two Track, 2/4 Shutters) 9.187.3.1 Two Track Sliding Frame (67mm x 52mm) 9.187.3.2 Sliding window Sash (60mm x 44mm) 9.187.3.3 Sliding Interlock for Window (one vertical length in each shutter)(45.5 mm x 28 mm) 9.187.3.4 Sliding Glazing bead (35 mm x 18 mm) 9.187.4 Sliding Door (Two Track, 2/4 Shutters) 9.187.4.1 Two Track Sliding Frame (67mm x 52mm) 9.187.4.2 Sliding Door Sash (80mm x 44mm) 9.187.4.3 Sliding Interlock for Door (one vertical length in each shutter) (45.5 mm x 28 mm) 9.187.4.4 Sliding Glazing bead (35 mm x 18 mm) 391 9.188 Providing and fixing stainless steel (SS- 304 grade) friction hinges to the side/ top hung UPVC windows, of approved quality with necessary stainless steel screws etc. as per direction of Engineer-in-charge. 9.188.1 200 x 19 x 1.9 mm 9.188.2 250 x 19 x 1.9 mm 9.188.3 300 x 19 x 1.9 mm 9.188.4 350 x 19 x 1.9 mm 9.188.5 400 x 19 x 1.9 mm 392 9.189 Providing and fixing casement handle made of zinc alloyed (white powder coated) for UPVC casement window with necessary screws etc. complete. 393 9.190 Providing and fixing zinc alloyed (white powder coated) touch lock for UPVC sliding window with necessary screws etc. complete. 394 9.191 Providing and fixing steel roller for UPVC sliding window with necessary screws etc. complete. 395 9.192 Providing and fixing steel roller for UPVC sliding door with necessary screws etc. complete. 396 9.193 Providing and fixing steel (white powder coated) crescent lock for UPVC sliding window/ door with necessary screws etc. complete. 397 9.194 Providing and fixing factory made UPVC white colour casement/casement cum fixed glazed windows comprising of UPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately) Note: For UPVC frame, sash and mullion extruded profiles minus 5% tolerancein dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. 9.194.1 Casement window single panel with S.S. friction hinges (300 x 19 x 1.9 mm), made of (small series) frame 47 x 50 mm & sash 47 x 68 mm both having wall thickness of 1.9 ± 0.2 mm and single glass pane glazing bead of appropriate dimension. (Area of window upto 0.75 sqm.) 9.194.2 Casement window double panels with S.S. friction hinges (300 x 19 x 1.9 mm) made of (small series) frame 47 x 50 mm, sash 47 x 68 mm & mullion 47 x 68 mm all having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension. (Area of window above 0.75 sqm upto 1.50 sqm). 9.194.3 Casement window double panels with top fixed with S.S. friction hinges (350 x 19 x 1.9 mm) made of (small series) frame 47 x 50 mm, sash 47 x 68 mm & mullion 47 x 68 mm all having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension. (Area of window upto 2.50 sqm). 9.194.4 Casement window single panel with S.S. friction hinges (400 x 19 x 1.9 mm) made of (big series) frame 67 x 60 mm & sash 67 x 80 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 0.75 sqm.) 9.194.5 Casement window duble panel with S.S. friction hinges (400 x 19 x 1.9 mm) made of (big series) frame 67 x 60 mm & sash 67 x 80 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 1.50 sqm.) 9.194.6 Casement cum fixed panel window having both and single casement panel, middle fixed panels and at top completely fixed ventilator with S.S. friction hinges (350 x 19 x 1.9 mm) made of (big series) frame 67 x 60 mm & sash 67 x 80 mm & mullion 67 x 80 all having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 3.00 sqm. Upto 5.00 sqm.) 398 9.195 Providing and fixing factory made UPVC white colour fixed glazed windows/ ventilators comprising of UPVC multi- chambered frame and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to UPVC profile), UPVC extruded glazing beads of appropriate dimension, EPDM gasket, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic capsof approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately). Note: - For UPVC frame, sash and mullion extruede profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. 9.195.1 Fixed window / ventilator made of (small series) frame 47 x 50 mm & mullion 47 x 68 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension. (Area upto 0.75 sqm.) 399 9.196 Providing and fixing made UPVC white colour casement/ casement cum fixed glazed door comprising of UPVC multi- chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length of approved quality, all complete as per approved drawing & direction of Engineer- in-Charge. (Single / double glass panes and silicon sealent shall be paid separately). Note: - For UPVC frame, sash and mullion extruede profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. 9.196.1 Casement door with 3D hinges made of (big series) frame 67 x 64 mm & sash 67 x 110 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of door upto 2.00 sqm). 9.196.2 Casement door with top hung ventilator with 3D and S.S. friction hinges (400 x 19 x 1.9 mm) made of (big series) frame 67 x 64 mm, sash 67 x 110 mm & mullion 67 x 80 mm all having wall thickness of 2.3 ±. 0.2 mm and single glazing bead /double glazing bead of appropriate dimension. (Area of door upto 2.50 sqm). 400 9.197 Providing and fixing factory made UPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of UPVC multi-chambered frame with in- built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately) Note: - For UPVC frame, sash and mullion extruede profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. 9.197.1 Two track two panels sliding window made of frame 52 x 44 mm &sash 32 x 60 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension. (Area of window upto 1.75 sqm) 9.197.2 Three track three panels sliding window with fly proof SS wire mesh (Two nos. glazed & one no. wire mesh panels) made of frame 92 x 44 mm & sash 32 x 60 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension (Area of window upto 1.75 sqm). 9.197.3 Two track two panels sliding window made of frame 67 x 50 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension (Area of window above 1.75 sqm upto 2.50 sqm). 9.197.4 Three track three panels sliding window with fly proof S.S wire mesh (Two nos. glazed & one no. wire mesh panels) made of frame 116 x 45 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead/double glazing bead of appropriate dimension. (Area of window above 1.75 sqm). 9.197.5 Three track three panels sliding window made of frame 116 x 45 mm & sash 46 x 62 mm both having wall thickness of 2.3 ±0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 1.75 sqm) 401 9.198 Providing and fixing factory made UPVC white colour sliding glazed window above 1.50 m in height dimension comprising of UPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately). Note: - For UPVC frame, sash and mullion extruede profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. 9.198.1 Two track two panels sliding window made of frame 67 x 50 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 2.50 sqm upto 4.00 sqm). 9.198.2 Two track four panels sliding window made of frame 67 x 50 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 4.00 sqm upto 8.00 sqm). 402 9.199 Providing and fixing factory made UPVC white colour sliding glazed door comprising of UPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section madAfter fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer- in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately).Note: - For UPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. 9.199.1 Two track two panels sliding door made of frame 67 x 50 mm & sash 46 x 82 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of door above 2.00 sqm upto 10.00 sqm). 9.199.2 Two track four panels sliding door made of frame 67 x 50 mm & sash 46 x 82 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of door above 8.00 sqm upto10.00 sqm). 9.199.3 Three track three panels sliding door made of frame 116 x 45 mm & sash 46 x 82 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead/ double glazing bead of appropriate dimension. (Area of door above 5.00 sqm) 9.199.4 Three track three panels sliding door with fly proof S.S wire mesh (Two nos. glazed & one no. wire mesh panels) made of frame 116 x 45 mm & sash 46 x 82 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of door above 2.00 sqm upto 5.00 sqm) 403 9.200 Providing and fixing 30mm thick factory made solid panel prelaminated PVC internal door shutter consisting of frame made out of M.S. tubes of 19 gauge thickness and size of 40mm x 20mm for styles top, lock and bottom rails. M.S. frame shall have a coat of steel primers of approved make and manufacture PVC beading as gap insert below top and bottom rail joined together using solvent cement adhesive. An additional 5mm thick Prelaminated PVC strip of 20mm width is to be stuck on the interior side of the ‘C’ channel using PVC solvent cement adhesive etc. complete as per direction of Engineer-in- charge. Manufacturer’s specification and drawing. 30 mm thick pre laminated PVC door shutters. 404 9.201 Providing and fixing factory made integral PVC flush door shutter made from rigid PVC foam sheet (Single Extruded) with density not less than 600 kg/cum, conforming to IS: 2380 part 14 for screw holding strength with Celluka finish surfaces on both sides at the manufacturing process itself, manufactured by an ISO : 9001 -2000 certified company. 9.201.1 24 to 25 mm thick plain solid PVC flush door shutter 9.201.2 28 to 30 mm thick plain solid PVC flush door shutter 405 9.202 Providing and fixing factory made pre laminated solid PVC flush door shutters 28 to 30 mm thick made from co-extruded three layer rigid PVC foam sheet with density not less than 600 kg/cum, conforming to IS: 2380 part 14, for screw holding strength and outer layers laminated on both sides by laminated sheet with density not less than 1400 kg/cum, lamination shall be at the manufacturing process itself and manufactured by an ISO: 9001-2000 certified company. 9.202.1 1mm thick laminated sheet 9.202.2 0.12 mm thick laminated sheet 406 9.203 Providing and fixing ISI marked factory made flush door shutters conforming to IS: 2202(Part-I) laminated type, core of block board construction with kiln seasoned and chemically treated 2nd class hard wood battens with well matched 3mm thick commercial 3ply veneering consisting of vertical grains, cross bands withing frame of door/cupboards and shall be stamped by the manufacturer to display name of manufacturer, batch number of product and conformity with IS: 2202. The rate shall be inclusive of all material and labour complete and as per specification and dirction of Engineer-in-Charge. 9.203.1 35mm thick including 4 nos. 100mm long, ISI marked heavy weight (2.5mm thick) Stainless steel butt hinges with necessary screws. 9.203.2 35mm thick including 3 nos. 100mm long, ISI marked heavy weight (2.5mm thick) Stainless steel butt hinges with necessary screws. 9.203.3 25mm thick (for cupboard) including 3 nos. 75mm long, ISI marked heavy weight (2.5mm thick) nickel plated bright finished M.S. piano hinges with necessary screws. 407 9.204 Providing and fixing ISI marked factory made flush door shutters conforming to IS: 2202(Part-I) non decorative type, core of block board construction with kiln seasoned and chemically treated 2nd class hard wood battens (strips) and frame of kiln seasoned and chemically treated, finger jointed cross bands including all material and labour complete as per specification and direction of engineer-in- charge. Spacing of finger joints in wood as above shall not be less than 50cm. Each shutter shall be factory made to the exact opening size within frame of doors/cupboards and shall be stamped by the manufacturer to display name of manufacturer, batch number of product and confirmity with IS:2202. 9.204.1 35mm thick including 4 nos. 100mm long, ISI marked heavy weight (2.5mm thick) Stainless steel butt hinges with necessary. 9.204.2 30mm thick including 3 nos. 100mm long, ISI marked heavy weight (2.5mm thick) Stainless steel butt hinges with necessary screws. 9.204.3 25mm thick including 3 nos. 100mm long, ISI marked heavy weight (2.5mm thick) Stainless steel butt hinges with necessary screws. 408 9.205 Deduct for not providing 2nd class teak wood batten lipping in factory made shutters i.e. item no 9.203 and 9.204. 409 9.206 Providing & fixing acrylic solid surface in thickness 4/6/12 mm of approved colour made out of non-porous surfacing material homogeneously composed of ± 1/3 acrylic resin (also known as PolyMethyl Methacrylate -PMMA), and ± 2/3 NO extra shall be paid for joint adhesive, silicon or related accessories and for transportation. Item should cover 5 years, commercial warranty of product as per FCWS norms. The product should be UV protected for exterior applications & LGA hyginene tested anti bacterial for health care application areas. Area of application are Table Tops, Exterior facade cladding, health care areas like modular operation theater hospital scrubs, wash basins, partition & paneling, laboratory commercial show room, hotels, office & residential areas. 9.206.1 Acrylic Solid Surface sheet – Glacier white designer white 9.206.1.1 6 mm thick sheet 9.206.1.2 12 mm thick sheet 9.206.2 Acrylic Solid Surface sheet - Any Solid colours/Hospital use Medi Blue 9.206.2.1 6 mm thick sheet 9.206.2.2 12 mm thick sheet 9.206.3 Acrylic Solid Surface sheet - Any other 9.206.3.1 6 mm thick sheet 9.206.3.2 12 mm thick sheet 410 9.207 Providing and fixing of 8 mm thick non asbestos multipurpose board reinforced with cellulose fibers for wall cladding will consist of following operations:1. Fixing of a layer of 6mm Moisture/fire Resistance Heavy Duty fibre cement Boards over above mentioned 6 mm heavy duty fibre cement board with the help of 25mm self drilling, self tapping Fibre Cement screws @ 300mm c/c. All external corners are to be protected with the use of suitable corner profile of GI or PVC. All above operation is to be done in order and as directed by Engineer-in-Charge.(frame work to be paid separately). 411 9.208 Providing and fixing IS marked factory made veneer High Density Fibre (HDF) flush door shutters conformity to IS: 15380(2003), eco-friendly, termite resistant, borer free, anti warping phenol formaldehyde (PF), decorative designe moulded or rate shall be inclusive of all material and labour complete as per specifications and direction of engineer-in-charge. Material supply company’ gujcon, century, green shall be registered by Bureau of Indian Standards, Member of Indian Green Building Council, ISO 9001, ISO 14001 (Environment management system), National small industries corporation(NSIC), SME Rating Agency of Indian Ltd.(SMERA), Dun and Bradstreet (D&B). 9.208.1 35 mm thick including 4 nos 100 mm long ISI marked heavy weight (2.5 mm thick) Stainless Steel butt hinges with necessary screws. 9.208.2 30 mm thick including 3 nos 100 mm long ISI marked heavy weight (2.5 mm thick) Stainless Steel butt hinges with necessary screws. 9.208.3 25 mm thick ISI marked heavy weight nickel plated bright finished M.S. piano hinges with screws. 412 9.209 Providing and fixing IS marked factory made veneer High Density Fibre (HDF) flush door shutters conformity to IS:15380(2003), eco-friendly, termite resistant borer free, anti warping phenol formaldehyde (PF), non decorative designe moulded and labor complete as per specifications and direction of engineer-in- charge. Material supply company shall be registered by Bureau of Indian Standards, Member of Indian Green Building Council, ISO 9001, ISO 14001 (Environment management system), National small industries corporation(NSIC), SME Rating Agency of Indian Ltd.(SMERA), Dun and Bradstreet (D&B). 9.209.1 35 mm thick including 4 nos 100 mm long ISI marked heavy weight (2.5 mm thick) Stainless Steel butt hinges with necessary screws. 9.209.2 30 mm thick including 3 nos 100 mm long ISI marked heavy weight (2.5 mm thick) Stainless Steel butt hinges with necessary screws 9.209.3 25 mm thick ISI marked heavy weight nickel plated bright finished M.S. piano hinges with screws. 413 9.210 Providing and fixing IS marked factory made High Density Fibre (HDF) flush door shutters conformity to IS:15380(2003), eco-friendly, termite resistant borer free, anti warping phenol formaldehyde (PF), 2 and 4 Panel designe moulded or plain construction with particle board shall be inclusive of all material and labour complete as per specifications and direction of engineer-in-charge. Material supply company shall be registered by Bureau of Indian Standards, Member of Indian Green Building Council, ISO 9001, ISO 14001 (Environment management system), National small industries corporation(NSIC), SME Rating Agency of Indian Ltd.(SMERA), Dun and Bradstreet (D&B). 9.210.1 35 mm thick including 4 nos 100 mm long ISI marked heavy weight (2.5 mm thick) Stainless Steel butt hinges with necessary screws. 9.210.2 30 mm thick including 3 nos 100 mm long ISI marked heavy weight (2.5 mm thick) Stainless Steel butt hinges with necessary screws. 414 9.211 HDF decorative prelaminated pine wood panel door with glass / wiremash:- Providing and fixing IS marked factory made veneer High Density Fibre (HDF) flush door shutters conformity to IS:15380(2003), eco-friendly, termite resistant borer free, anti warping phenol formaldehyde (PF), The rate shall be inclusive of all material and labour complete as per specifications and direction of engineer-in-charge. Material supply company shall be registered by Bureau of Indian Standards, Member of Indian Green Building Council, ISO 9001, ISO 14001 (Environment management system), National small industries corporation(NSIC), SME Rating Agency of Indian Ltd.(SMERA), Dun and Bradstreet (D&B). 9.211.1 35 mm thick including 4 nos 100 mm long ISI marked heavy weight (2.5 mm thick) Stainless Steel butt hinges with necessary screws. 9.211.2 30 mm thick including 3 nos 100 mm long ISI marked heavy weight (2.5 mm thick) Stainless Steel butt hinges with necessary screws. 415 9.212 Providing and fixing IS marked factory made veneer High Density Fibre (HDF) flush door shutters conformity to IS:15380(2003), eco-friendly, termite resistant borer free, anti warping phenol formaldehyde (PF), . The rate shall be inclusive of all material and labour complete as per specifications and direction of engineer-in-charge. Material supply company shall be registered by Bureau of Indian Standards, Member of Indian Green Building Council, ISO 9001, ISO 14001 (Environment management system), National small industries corporation(NSIC), SME Rating Agency of Indian Ltd.(SMERA), Dun and Bradstreet (D&B). 9.212.1 35 mm thick including 4 nos 100 mm long ISI marked heavy weight (2.5 mm thick) Stainless Steel butt hinges with necessary screws. 9.212.2 32 mm thick including 3 nos 100 mm long ISI marked heavy weight (2.5 mm thick) Stainless Steel butt hinges with necessary screws. 9.212.3 25 mm thick ISI marked heavy weight nickel plated bright finished M.S. Piano hinges with screws. 416 9.213 Non Decorative Pine Wood Flush Door:- Providing and fixing ISI marked factory made flush door shutters conforming to IS: 2202 (Part I) non decorative type, core of block board construction with kiln seasoned and chemically treated 1st class pine wood battens (strips) and chemically treated, finger jointed all material and labour complete as per specification and direction of engineer- in-charge. Spacing of finger joints in wood as above shall not be less than 50 cm. Each shutter shall be factory made to the exact opening size within frame of doors/ cupboards and shall be stamped by the manufacturer to display name of manufacturer, batch number of product and conformity with IS:2202 9.213.1 35 mm thick including 4 nos. 100 mm long, ISI marked heavy weight (2.5mm thick) Stainless Steel butt hinges with necessary screws. 9.213.2 30 mm thick including 3 nos. 100 mm long, ISI marked heavy weight (2.5mm thick) Stainless Steel butt hinges with necessary screws. 9.213.3 25mm thick (for cupboard) including 3 nos. 75 mm long, ISI marked heavy weight (2.5mm thick) nickel plated bright finished M.S. piano hinges with necessary screws. 417 9.214 Providing and fixing ISI marked factory made flush door shutters conforming to IS: 2202 (Part I) laminated type, core of block board construction with kiln seasoned and chemically treated 1st class pine wood battens (strips) and frame of kiln seasoned sheet shall be as per IS: 2046 type S of approved quality. Each shutter shall be factory made to the exact size (opening) within frame of doors/ cupboards and shall be stamped by the manufacturer to display name of manufacturer, batch number of product and conformity with IS:2202. The rate shall be inclusive of all material and labour complete and as per specification and direction of engineer-in- charge. 9.214.1 35 mm thick including 4 nos. 100 mm long, ISI marked heavy weight (2.5mm thick) Stainless Steel butt hinges with necessary screws. 9.214.2 30 mm thick including 3 nos. 100 mm long, ISI marked heavy weight (2.5mm thick) Stainless Steel butt hinges with necessary screws. 9.214.3 25mm thick (for cupboard) including 3 nos. 75 mm long, ISI marked heavy weight (2.5mm thick) nickel plated bright finished M.S. piano hinges with necessary screws. 418 9.215 Providing and fixing ISI marked factory made flush door shutters conforming to IS: 2202 (Part I) laminated type, core of block board construction with kiln seasoned and chemically treated 1st class pine wood battens (strips) and frame of kiln seasoned within frame of doors/ cupboards and shall be stamped by the manufacturer to display name of manufacturer, batch number of product and conformity with IS:2202. The rate shall be inclusive of all material and labour complete and as per specification and direction of engineer-in-charge. 9.215.1 35 mm thick including 4 nos. 100 mm long, ISI marked heavy weight (2.5mm thick) Stainless Steel butt hinges with necessary screws. 9.215.2 30 mm thick including 3 nos. 100 mm long, ISI marked heavy weight (2.5mm thick) Stainless Steel butt hinges with necessary screws. 9.215.3 25mm thick (for cupboard) including 3 nos. 75 mm long ISI marked heavy weight (2.5mm thick) nickel plated bright finished M.S. piano hinges with necessary screws. 419 9.216 Providing and fixing ISI marked factory made flush door shutters conforming to IS: 2202 (Part I) veneer decorative type, core of block board construction with kiln seasoned and chemically treated 1st class pine wood battens (strips) s and commercial grade face veneers on both outer faces of shutters including kiln seasoned and chemically treated, finger jointed all material and labour complete as per specification and direction of engineer-in- charge. Spacing of finger joints in wood as above shall not be less than 50 cm. Each shutter shall be factory made to the exact opening size within frame of doors/ cupboards and shall be stamped by the manufacturer to display name of manufacturer, batch number of product and conformity with IS:2202. 9.216.1 35 mm thick including 4 nos. 100 mm long, ISI marked heavy weight (2.5mm thick) Stainless Steel butt hinges with necessary screws. 9.216.2 30 mm thick including 3 nos. 100 mm long, ISI marked heavy weight (2.5mm thick) Stainless Steel butt hinges with necessary screws. 9.216.3 25mm thick (for cupboard) including 3 nos. 75 mm long, ISI marked heavy weight (2.5mm thick) nickel plated bright finished M.S. piano hinges with necessary screws. 420 9.217 Providing and fixing factory made solid Foam uPVC profile for kitchen cabinet frame (45 x 20 mm) of approved shade, quality and make. The profile shall be laminated on both sides,made from rigid foam sheets (Single extruded) having density 600 Kg/cum and the exposed edges sealed with PVC edge beading of same shade and colour. The frame shall be fire retardent with necessary screw holding capacity. Frame shall be fixed to wall using Expendable Fastne with necesary stainless steel screws, all complete as per direction of Engineer-in-charge. 421 9.218 Providing and fixing factory made Kitchen Cabinet Shutter/Partition 20 mm nominal thickness of approved shade, quality and make, made from rigid foam sheets (Single extruded) having density 600 Kg/cum and laminated on both side by laminate Sheet/PVC foil lamination. The exposed edges shall be sealed with PVC edge beading of same shade and colour. The shutter shall be fire retardent having necessary screw holding capacity.Shutter shall be fixed to frame using approved hinges with necessary stainless steel screws, all complete as per direction of Engineer-in-charge. 422 10.1 Structural steel work in single section fixed with or without connecting plate including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. 423 10.2 Structural steel work using M.S. flats, angles, channels I-section, H-section etc. riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. 424 10.3 Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2mm and braced with flat iron diagonals 20x5mm size with top and bottom rail of T-iron 40x40x6mm with 40mm dia steel pulleys complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer. Rate includes recess cutting in floor and making good the same wherever required. 425 10.4 Providing and fixing 1mm thick M.S. sheet sliding-shutters with frame and diagonal braces of 40x40x6mm angle iron, 3mm M.S.gusset plates at the junction and corners 25mm dia pulley,40x40x6mm angle and T-iron guide at the top and bottom respectively including applying a priming coat of approved steel primer. 426 10.5 Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x5mm angle iron and 3mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. 10.5.1 Using M.S. angels 40x40x6mm for diagonal braces 10.5.2 Using flats 30x6mm for diagonal braces and central cross piece. 427 10.6 Supplying and fixing rolling shutters of approved make, made of required size M.S. laths interlocked together through their entire length and jointed together at the end by end locks mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete including the cost of providing and fixing necessary 27.5cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to I.S. 4454- part-1 and M.S. top cover of required thickness for rolling shutters. 10.6.1 80x1.25mm M.S. laths with 1.25 mm thick top cover. 10.6.2 80x1.20 mm M.S. laths with 1.20 mm thick top cover. 10.6.3 80x0.90 mm M.S. laths with 0.90 mm thick top cover. 428 10.7 Extra for providing suitable mechanical device chain and crank operation for operating rolling shutters. 10.7.1 Exceeding 10.00 sqm and upto 16.80 sqm in the area. 10.7.2 Exceeding 16.80 sqm in area. 429 10.8 Extra for providing grilled rolling shutters manufactured out of 8 mm dia. M.S. bar instead of laths as per design approved by Engineer-in-Charge. (Area of grill to be measured). 430 10.9 Providing and fixing ball bearing for rolling shutters. 431 10.10 Providing and fixing factory made ISI marked glazed steel doors, windows and ventilators side /top /centre hung with beading and Z-section all members such as F7D, F4B, K11 B and K12 B and other tubular section member etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design (sectional weight of only steel members shall be measured for payment). 10.10.1 Fixing with 15x3 mm lugs 10 cm. long embedded in cement concrete block 15x10x10 cm of Cement Concrete 1:3:6 (1 Cement : 3 sand : 6 graded stone aggregate 20 mm nominal size). 10.10.2 Fixing with carbon steel galvanised dash fastener of required dia and size (to be paid for separately). 10.10.3 Extra for providing and fixing steel beading of size 10x10x1.6mm (box type) approved shape and section with screws instead of glazing clips and metal sash putty in steel doors, windows, ventilators and composite units. 432 10.11 Providing and fixing L-iron or T-iron frames for doors, windows and ventilators of mild steel L-section or T-sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. 10.11.2 Fixing with carbon steel galvanised dash fastener of required dia and size (to be paid for separately). 433 10.12 Providing and fixing pressed steel door frames made of 1.6 mm thick steel profile conforming to IS: 4351 manufactured from commercial mild steel sheet including hinges, jamb, lock jamb, M.S. pressed butt hinges, with mortar guards, lock strike-plate and shock absorbers as specified filling the frame with Cement Concrete 1:3:6 at site before fixing (cost of concrete to be paid separately) fixing with adjustable lugs (200 mm long & 1.0 mm thick) and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in- charge: 10.12.1 Profile B of 1.60mm thick single rebate of size 80mmx50mm 10.12.1.1 Fixing with adjustable lugs with split end tail to each jamb. 10.12.1.2 Fixing with carbon steel galvanised dash fastener of required dia and size (to be paid for separately). 10.12.2 Profile C of 1.60mm thick single rebate of size 100mmx50mm 10.12.2.1 Fixing with adjustable lugs with split end tail to each jamb. 10.12.2.2 Fixing with carbon steel galvanised dash fastener of required dia and size (to be paid for separately). 10.12.3 Profile E of 1.60mm thick double rebate of size 115mmx50mm 10.12.3.1 Fixing with adjustable lugs with split end tail to each jamb. 10.12.3.2 Fixing with carbon steel galvanised dash fastener of required dia and size (to be paid for separately). 10.12.4 Profile B of 1.25mm thick single rebate of size 80mmx50mm 10.12.4.1 Fixing with adjustable lugs with split end tail to each jamb. 10.12.4.2 Fixing with carbon steel galvanised dash fastener of required dia and size (to be paid for separately). 10.12.5 Profile C of 1.25mm thick single rebate of size 100mmx50mm 10.12.5.1 Fixing with adjustable lugs with split end tail to each jamb. 10.12.5.2 Fixing with carbon steel galvanised dash fastener of required dia and size (to be paid for separately). 10.12.6 Profile E of 1.25mm thick double rebate of size 115mmx50mm 10.12.6.1 Fixing with adjustable lugs with split end tail to each jamb. 10.12.6.2 Fixing with carbon steel galvanised dash fastener of required dia and size (to be paid for separately). 434 10.13 Providing and fixing M.S. Tubular frames and shutters or frames only or shutters only for doors, windows, ventilators and cupboard with any sections, made of 1.60 mm or 1.25 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size as per drawing, including fixing of necessary butt hinges, stays and screws and applying a priming coat of approved steel primer excluding cost of all fittings such as handles, tower bolts, sliding door bolts, latches etc. and panels. 10.13.1 Fixing with 15x3 mm lugs 10 cm. long embedded in cement concrete block 15x10x10 cm of Cement Concrete 1:3:6 (1 Cement : 3 sand : 6 graded stone aggregate 20 mm nominal size). 10.13.2 Fixing with carbon steel galvanised dash fastener of required dia and size (to be paid for separately). 435 10.14 Steel work in built up M.S. tubular section (round, square or rectangular hollow tubes etc.) trusses/frame work etc. including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. 10.14.1 Hot finished welded type tubes 10.14.2 Hot finished seamless type tubes 10.14.3 Electric resistance or induction butt welded tubes. 436 10.15 Design, supply, fabrication, taransportion and erection of structural steel/mild steel built-up sections for steel building in column, rafter, truss, floor joist, wind bracings, tie beam, foundation bolts, fasteners etc. Including two coats of Epoxy paint and one coat of primer. These structural steel/built-up sections shall be manufactured using advanced CNC Plasma/Oxy Acetylene cutter and H Beam Welding line. Welding shall be in full depth on both sides of the plate adopting relevant I.S Code. 437 10.16 Providing and fixing M.S. fan clamp type I or II of 16 mm dia M.S. bar bent to shape with hooked ends in R.C.C. slabs, beams during laying including painting the exposed portion of loop, all as per standard design complete. 438 10.17 Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp of internal dia 140mm, 73mm height, top lid of 1.5mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3mm dia. round headed screws, one lock at the corners. Clamp shall be made of 16mm dia M.S. bar bent to shape as per standard drawing. 439 10.18 Providing and fixing mild steel round holding down bolts with nuts and washer plates complete. 440 10.19 Providing and fixing bolts including nuts and washers complete. 441 10.20 Providing and fixing M.S. rivets of sizes in position. 442 10.21 Welding by gas or electric plant including transportation of plant at site etc. complete. 443 10.22 Steel work welded in built up sections/ framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. 10.22.1 In stringers, treads, landings etc. of stair cases including use of chequered plate wherever required, all complete. 10.22.2 In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works. 444 10.23 Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying a priming coat of approved steel primer. 10.23.1 M.S. tube. 10.23.2 E.R.W. tubes. 445 10.24 Providing and fixing carbon steel galvanised (minimum coating 5 micron) dash fastener of 10 mm dia double threaded 6.8 grade (yield strength 480 N/mm2), counter sunk head, comprising of 10 mm dia polyamide PA 6 grade sleeve, including drilling of hole in frame, concrete/ masonry, etc. as per direction of Engineer-in-charge. 10.24.1 10x60 mm 10.24.2 10x80 mm 10.24.3 10x120 mm 10.24.4 10x140 mm 10.24.5 10x160mm 446 10.25 Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc. including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete i/c fixing the railing with necessary accessories and stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge. (For payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) 447 10.26 Providing and fixing fly proof wire gauze to windows, clerestory windows and doors with M.S. Flat 15x3mm and nuts and bolts complete. 10.26.1 Galvanised M.S. Wire gauze with 0.63mm dia wire and 1.4 mm aperture on both sides 10.26.2 Stainless steel (grade 304) wire gauze of 0.5 mm dia wire and 1.4 mm aperture on both sides. 448 10.27 Providing and fixing glass panes/ steel sheet/ fibre sheet with putty and glazing clips in steel doors, windows, clerestory windows all complete. 10.27.1 With 4.0 mm thick glass panes 10.27.2 With 5.50 mm thick glass panes 10.27.3 With 1mm thick mild steel sheet i/c 10x10x1.6mm box beading. 10.27.4 With 2mm thick fibre reinforced polymer (FRP) sheet i/c 10x10x1.6mm box beading. 10.27.5 With 1mm thick Galvanised steel sheet i/c 10x10x1.6mm box beading. 10.27.6 With 4mm thick cement fibre board conforming to IS 14862:2000 of category type A grade i/c 10x10x1.6mm box beading. 10.27.7 With 6mm thick cement fibre board conforming to IS 14862:2000 of category type A grade i/c 10x10x1.6mm box beading. 10.27.8 With 8mm thick cement fibre board conforming to IS 14862:2000 of category type A grade i/c 10x10x1.6mm box beading. 449 10.28 Add extra for providing and fixing froasted glass instead of float glass. 10.28.1 With 4.0 mm thick glass panes. 10.28.2 With 5.5 mm thick glass panes. 450 10.29 Supplying at site: 10.29.1 R.C.C. Standards post/ struts/rails/ poles of mix 1:1.5:3 (1 cement : 1.5 sand : 3 graded stone aggregate 12.5 mm nominal size) with wooden plugs or 6mm bar nibs wherever required as per direction of Engineer-in-charge including fixing (cost of earth works in excavation, concrete works in foundation to be paid separately). 10.29.2 Angle iron post and strut of required size including bottom to be split and bent at right angle in opposite direction for 10 cm length and drilling holes upto 10 mm dia. etc. complete. (cost of earth work in excavation and concrete work in foundation to be paid separately) 10.29.3 Supplying at site -Welded steel wire fabric of required width having rectangular mesh painted with two or more coats of enamel paint of approved shade over a coat of primer (Priming painting to be paid for separately). 451 10.30 Supplying and fixing turn buckles and straining bolts for barbed wire fencing. (Labour rate only). 452 10.31 Fencing with R.C.C. post placed at required distance, embedded in cement concrete blocks, every 15th post, last but one end post and corner post shall be strutted on both sides and end post one side between the two posts fitted and fixed with G.I. staples on wooden plugs or G.I. binding wire tied to 6 mm bar nibs fixed while casting the post (cost of R.C.C. posts, struts, earth work and concrete to be paid for separately) with GI barbed wire. 453 10.32 Fencing with barbed G.I. wire angle iron post placed fitted to at required distance embedded in cement concrete blocks, every 15th post, last but one end post and corner post shall be strutted on both sides between the two posts fitted and fixed with G.I. staples, turn buckles etc. complete. (Cost of posts, struts, earth work and concrete work to be paid for separately):- Payment to be made per metre cost of total length of barbed wire used. 454 10.33 Fixing Welded steel wire fabric fencing with posts of specified material and of standard design placed and embedded in cement concrete blocks 45x45x60cm of mix 1:5:10 (1cement :5 sand :10 graded stone aggregate 40mm nominal size) every 15th post, last but one end post and corner post shall be strutted on both sides and end post on one side only and struts embedded in cement concrete blocks 70x45x50cm of the same mix, provided with welded steel wire fabric fixed between the posts fitted and fixed with G.I. staples on wooden plugs or tied to 6 mm bar nibs with G.I. binding wire (cost of posts, painting, earth work in excavation and cement concrete to be paid for separately). (Labour rate only). 455 10.34 Providing and fixing G.I. or PVC coated G.I.wire chain link fabric fencing of required width and mesh size including strengthening with 2mm dia wire or nuts, bolts and washers as required complete with posts of specified material and of standard design placed and embedded in cement concrete blocks 45x45x60cm of mix 1:5:10 (1cement :5 sand :10 graded stone aggregate 40mm nominal size) every 15th post, last but one end post and corner post shall be strutted on both sides and end post on one side only and struts embedded in cement concrete blocks 70x45x50cm of the same mix, as per the direction of Engineer- in-charge. (Cost of post, painting earthwork & c.c. to be paid separately) 10.34.1 Made of G.I. wire. 10.34.2 Made of G.I. wire, PVC coated to achieve outer dia. not less than 5mm in required colour and shade. 456 10.35 Providing and fixing G.I. chain link fabric fencing of required width in mesh size 25x25 mm made of G.I. wire of dia. 3mm including strengthening with 2mm dia. wire or nuts, bolts and washers as required complete, with posts of specified material and of standard design placed and embedded in cement concrete blocks 45x45x60cm of mix 1:5:10 (1cement :5 sand : 10 graded stone aggregate 40mm nominal size) every 15th post, last but one end post and corner post shall be strutted on both sides and end post on one side only and struts embedded in cement concrete blocks 70x45x50cm of the same mix, as per the direction of Engineer-in- Charge. (cost of post painting earth work & C.C. to be paid separately) 457 10.36 Providing and fixing concertina coil fencing with punched tape concertina coil 600 mm dia 10 metre openable length (total length 90 m), having 50 nos rounds per 6 metre length, upto 3 m height of wall with existing angle iron Y shaped placed 2.4m or 3.00m apart and with 9 horizontal R.B.T. reinforced barbed wire, stud tied with G.I. staples and G.I. clips to retain horizontal, including necessary bolts or G.I. barbed wire tied to angle iron, all complete as per direction of Engineer-in charge, with reinforced barbed tape(R.B.T.) / Spring core (2.5 mm thick) wire of high tensile strength of 165 kg/ sq mm with tape (0.52 mm thick) and weight 43.478 gm/ metre (cost of M.S. angle, C.C. blocks shall be paid separately). 458 10.37 Providing and fixing of ISI marked insulated fire rated GI Sheet doors conforming to FD 120-PI classification of IS 3614:2021 with fire rating of 120 minutes integrity and 30 minutes insulation. The factory manufactured door frame and shutter assembly shall be made out of minimum 120 GSM coating as per IS: 277. Door and frame should be finished with powder coating in standard RAL shade finish having DFT of minimum 30 microns. The door should carry a minimum 500 Hrs of salt spray test. All accessories like hardware, vision panel, fire & smoke seal etc to be supplied by Fire door manufacturer only as per the guidelines laid down in IS 3614:2021.Every door must carry a label confirming to type of door & its fire rating. The Door frame shall be single rebate grooved profile of size minimum 125 mm x 75mm made out of 1.50mm minimum thick galvanized steel sheet. Frames shall be butt / mitered joint and field assembled with bolting system. Frames to have inbuilt grooved to accommodate Intumescent fire seal strip. Frames to have inbuilt grooved to accommodate Intumescent fire seal strip of size 10x4mm. All provisions should be mortised & provided with necessary inbuilt reinforcement to receive appropriate hardware. Frames should be provided with back plate bracket for anchor fastner with 8-10 mm dia and minimum 80 mm long HDG fasteners, with Polyamide sleeves (Payable in extra item) for installation of frame in finished plastered masonary wall opening. Note:- For grouting of Steel frames in masonary installations ;cement slurry of 1:3 ratio by civil contractor/fire rated PU foam or such fire rated material may be recommended except head member(Payable in extra item). Door leaf should be minimum 60mm thick fully flush double skin door. Door leaf must be manufactured from minimum 1.2mm thick galvanised steel sheet. The infill material shall be mineral wool of minimum density 96 kg/cum. All doors shall befactory prepped for receiving appropriate hardware and provided with necessary reinforcement for hinges, locks, and door closers. The edges should be interlocked with a bending radius of 1.4mm. For double leaf doors integrated astragals has to be provided on the meeting stile for both active and inactive leaf.The shutters shall be mounted to the frame with SS 304 grade ball bearing type hinges of size 100x 89x3 mm along with all suitable hardware (Payable in extra item).Vision lite size 185x285 (max area up to 0.06sqm) wherever applicable should be provided with single layered clear fire rated glass panes as per guidelines laid down under IS 3614 : 2021 vide clause no. 7.2.7 table no. 2 with a clip on arrangement. The glass will be provided with fire rated ceramic tape of min. 2 mm thickness with min. 15mm width al around on either face. Every Glass pane must carry a permanent marking of its glass manufacturer 459 10.38 Providing and fixing of factory make air tight casement windows made of roll formed galvanized pre-painted steel with epoxy primer of 5-7 microns thick, finish painted with a polyester paint of 12-16 microns thick and back coated with alkyd backer 5-7 microns thick or powder coated with pure polyester powder up to 50-60 microns Including filling the gap upto 5 mm depth and 5 mm width in between steel frame and adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete. 10.38.1 Openable window 10.38.2 Fixed windows 460 10.39 Providing and fixing of factory make single rebate openable/fixed windows made of roll formed galvanized pre- pained steel with epoxy primer of 5-7 microns thick, finish painted with a polyester paint of 12-16 microns thick and back coated with alkyd backer 5-7 microns thick) heavy duty pivot hinges per shutter and window fitted without glazing including 10mm square bars welded to 6x12mm flat at a distance 150mm c/c (pitch) etc. Including filling the gap upto 5 mm depth and 5 mm width in between steel frame and adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in- charge complete. 10.39.1 Openable single rebate window 10.39.2 Fixed single rebate window 461 10.40 Providing and fixing of factory make double rebate windows made of roll formed galvanized pre-painted steel with epoxy primer of 5-7 microns thick, finish painted with a polyester paint of 12-16 microns thick and back coated with alkyd backer 5-7 microns thick or powder coated with pure polyester powder up to 50-60 microns thick, fitted using EPDM (Ethyl Propylene Diamine Monomer) gaskets including fixing windows in the concrete/masonry wall by means of self- expanding screws, including 10mm Square bars welded to 6x12mm flat at a distance 150mm c/c (pitch) etc. Including filling the gap upto 5 mm depth and 5 mm width in between steel frame and adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in- charge complete.. 10.40.1 Openable double rebate window 10.40.2 Fixed double rebate window 462 10.41 Providing and fixing of factory make fixed louvers fabricated from roll formed sections made of galvanized pre-painted steel with epoxy primer of 5-7 microns thick, finish painted with a polyester paint of 12-16 microns thick and back coated with alkyd backer 5-7 microns thick or powder coated with pure polyester powder up to 50-60 microns thick, colour coated/powder coated Including filling the gap upto 5 mm depth and 5 mm width in between steel frame and adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in- charge complete. (glazing shall be paid separately as per SOR rate) 463 10.42 Providing and fixing of factory make pre painted steel sliding window 2 track-2 panel sliding window fabricated from roll formed sections made of galvanized steel with epoxy primer of 5-7 microns thick, finish painted with a polyester paint of 12-16 microns thick and back coated with alkyd backer 5-7 microns thick or powder coated with pure polyester powder up to 50-60 microns The above frames should be fixed to the concrete/masonry walls by means of self-expanding screws. Including filling the gap upto 5 mm depth and 5 mm width in between steel frame and adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete. 464 10.43 Providing and fixing pre painted steel sliding window 3 fabricated from Roll formed sections made of galvanized Steel with epoxy primer of 5-7 microns thick, finish painted with a polyester paint of 12-16 microns thick and back coated with alkyd backer 5-7 microns thick or powder coated with pure polyester powder up to 50-60 microns The above frames should be fixed to the concrete/masonry walls by means of self-expanding screws. Including filling the gap upto 5 mm depth and 5 mm width in between steel frame and adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete. 465 11.1 40 mm thick Cement concrete flooring 1:2:4 (1 cement : 2 sand : 4 graded stone aggregate) 20mm nominal size stone aggregate in panels finished with a floating coat of neat cement including cement slurry, but excluding the cost of nosing of steps etc. complete.(Area of panel not to exceed 2.0 sqm) 466 11.2 52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement: 2 sand: 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix: 2 graded stone aggregate 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50kg of cement or as per manufacturers specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete. 467 11.3 62 mm thick cement concrete flooring with concrete hardener topping, under layer 50 mm thick cement concrete 1:2:4 (1 cement: 2 sand: 4 graded stone aggregate 20mm nominal size) and top layer 12mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix: 2 graded stone aggregate, 6mm nominal size) by volume, hardening compound mixed @ 2 litre per 50kg of cement or as per manufactures specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete. 468 11.4 Cement plaster skirting 18 mm thick (upto 30 cm height) with cement mortar 1:3 (1 cement: 3 sand) finished with a floating coat of neat cement. 469 11.5 Cement concrete pavement with Cement concrete 1:2:4 (1 cement: 2 sand: 4 graded stone aggregate 20 mm nominal size) including finishing complete. 470 11.6 Making chequers of approved pattern on cement concrete floors, steps, landing, pavements etc. 471 11.7 40 mm thick marble chips flooring rubbed and polished to granolithic finish, under layer 34 mm thick cement concrete 1:2:4 (1 cement : 2 sand : 4 graded stone aggregate 12.5mm nominal size) and top layer 6mm thick with white, black, chocolate, grey, yellow or green marble chips of sizes from 1mm to 4mm nominal size laid in cement marble powder mix 3:1 (3 cement : 1 marble powder) by weight in proportion of 4:7 (4 cement marble powder mix : 7 marble chips) by volume including cement slurry etc. complete : (Area of panel not to exceed 2.0 sqm) 11.7.1 Dark shade pigment with ordinary cement. 11.7.2 Light shade pigment with white cement. 11.7.3 Medium shade pigment with 50% white cement and 50% ordinary cement. 11.7.4 White cement without any pigment. 11.7.5 Light shade pigment with ordinary cement. 11.7.6 Ordinary cement without any pigment. 472 11.8 40 mm thick marble chips flooring, rubbed and polished to granolithic finish, under layer 31mm thick cement concrete 1:2:4 (1 cement : 2 sand : 4 graded stone aggregate 12.5mm nominal size) and top layer 9mm thick with white, black, chocolate, grey, yellow or green marble chips of sizes from 4mm to 7mm nominal size laid in cement marble powder mix 3:1 (3 cement : 1 marble powder) by weight in proportion of 4:7 (4 cement marble powder : 7 marble chips) by volume including cement slurry etc. complete. (Area of panel not to exceed 2.0 sqm) 11.8.1 Dark shade pigment with Ordinary cement. 11.8.2 Light shade pigment with white cement. 11.8.3 Medium shade pigment with 50% white cement and 50% ordinary cement. 11.8.4 White cement without any pigment. 11.8.5 Light shade pigment with ordinary cement. 11.8.6 Ordinary cement without any pigment. 473 11.9 40 mm thick marble chips flooring, rubbed and polished to granolithic finish, under layer 28 mm thick cement concrete 1:2:4 (1 cement : 2 sand : 4 graded stone aggregate 12.5mm nominal size) and top layer 12mm thick with white, black, chocolate, grey yellow or green marble chips of sizes from 7mm to 10mm nominal size laid in cement marble powder mix 3:1 (3 cement : 1 marble powder) by weight in proportion of 2:3 (2 cement marble powder mix : 3 marble chips) by volume including cement slurry etc. complete : (Area of panel not to exceed 2.0 sqm) 11.9.1 Dark shade pigment with ordinary cement. 11.9.2 Light shade pigment with white cement. 11.9.3 Medium shade pigment with 50% white cement and 50% ordinary cement. 11.9.4 White cement without any pigment. 11.9.5 Light shade pigment with ordinary cement. 11.9.6 Ordinary cement without any pigment. 474 11.10 Marble chips skirting (upto 30 cm height) 18 mm thick with under layer 12 mm thick in cement plaster 1:3 (1 cement : 3 sand) : rubbed and polished to granolithic finish, top layer 6 mm thick with white, black, chocolate, grey, yellow or green marble chips of sizes from smallest to 4 mm nominal size laid in cement marble powder mix 3:1 (3 cement : 1 marble powder) by weight in proportion of 4:7 (4 cement marble powder mix :7 marble chips) by volume : 11.10.1 Dark shade pigment with ordinary cement. 11.10.2 Light shade pigment with white cement. 11.10.3 Medium shade pigment with 50% white cement and 50% ordinary cement. 11.10.4 White cement without any pigment. 11.10.5 Light shade pigment with ordinary cement. 11.10.6 Ordinary cement without any pigment. 475 11.11 Extra for laying terrazo flooring on staircase treads not exceeding 30 cm in width including cost of forming, nosing etc. 476 11.12 Providing and fixing glass strips 40 mm wide and 4 mm thick in joints of terrazo/ cement concrete floors. 477 11.13 18 mm thick crazy marble stone white, black or as specified marble stone flooring, including filling the gaps with light shade pigment with white cement marble powder mixture (3 parts of white cement : 1 part of marble powder) by weight in proportion of 4:7 (4 cement marble powder mix : 7 white, black or white and black marble chips of sizes from 1mm to 4mm nominal size by volume), with under layer 25mm thick cement concrete 1:2:4 (1 cement : 2 sand : 4 graded stone aggregate 12.5 mm nominal size), including rubbing, polishing and cement slurry etc.complete . 478 11.14 Precast terrazo tiles 22mm thick with graded marble chips of size upto12mm, laid in floors, and landings, jointed with neat cement slurry mixed with pigment to match the shade of the tiles including rubbing and polishing complete, on 20 mm thick bed of cement mortar 1:4 (1 cement :4 sand) : 11.14.1 Light shade using white cement. 11.14.2 Medium shade using 50%white cement and 50% ordinary cement. 11.14.3 Dark shade using ordinary cement. 11.14.4 Ordinary cement without any pigment. 479 11.15 Extra if terrazo tiles are laid in treads of steps not exceeding 30 cm in width. 480 11.16 Precast terrazo tiles 22 mm thick with graded marble chips of sizes upto 12 mm in skirting and risers of steps not exceeding 30 cm in height on 12 mm thick cement plaster 1:3 (1 cement : 3 sand) jointed with neat cement slurry mixed with pigment to match the shade of the tiles, including rubbing and polishing complete with tiles of : 11.16.1 Light shade pigment using white cement. 11.16.2 Medium shades pigment using 50% white cement and 50% ordinary cement. 11.16.3 Dark shade pigment using ordinary cement. 11.16.4 Ordinary cement without any pigment. 481 11.17 Chequeredterrazo tiles 22 mm thick with graded marble chips of size up to 6 mm in floors jointed with neat cement slurry mixed with pigment to match the shade of the tiles including rubbing and polishing complete on 20 mm thick bed of cement mortar 1:4 (1 cement :4 sand) : 11.17.1 Light shade pigment using white cement. 11.17.2 Medium shade pigment using 50% white cement, 50% ordinary cement. 11.17.3 Dark shade pigment using ordinary cement. 11.17.4 Ordinary cement without any pigment. 482 11.18 Chequered precast cement concrete tiles any finish, any size 22 mm thick IS:13810-1993 ISI mark in footpath and courtyard jointed with neat cement slurry mixed with pigment to match the shade of tiles, 15mm thick screed bad in cement mortar 1:6 complete all as specified and directed by Engineer-in-Charge. 11.18.1 Light shade pigment using white cement. 11.18.2 Medium shade pigment using 50% white cement 50% Grey cement. 11.18.3 Dark shade pigment using ordinary cement. 11.18.4 Ordinary cement without any pigment. 483 11.19 Marble stone flooring with 18 mm thick marble stone (sample of marble shall be approved by Engineer-in-charge) laid over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 sandand grey cement slurry, joints treated with white cement mixed with pigment to match colour of stone including rubbing and polishing complete with : (area of slabs over 0.5 sqm) 11.19.1 Makrana white second quality. 11.19.2 Raj Nagar plain. 11.19.3 Agaria White/Morgarh 11.19.4 Katni marble 11.19.5 Black Zebra. 11.19.6 Udaipur / Baroda green marble 11.19.7 Pink plain marble. 11.19.8 Jaisalmer Yellow 484 11.20 Marble stone 18 mm thick in riser of step, skirting, dado and pillar laid on 12 mm average thick cement mortar 1:3 (1 cement: 3 sand and laid with white cement slurry) joints treated with white cement mixed with pigment to match the shade of the slab i/c rubbing and polishing complete. (area of slab over0.50sqm.) 11.20.1 Makrana white second quality. 11.20.2 Raj Nagar plain. 11.20.3 Agaria White/Morgarh 11.20.4 Katni marble 11.20.5 Black Zebra. 11.20.6 Udaipur / Baroda green marble 11.20.7 Pink plain marble. 11.20.8 Jaisalmer Yellow 485 11.21 Marble work gang saw cut (polished and machine cut) of thickness 18 mm for wall lining (veneer work), backing filled with a grout of average 12 mm thick in cement mortar 1:3 (1 cement: 3 sand), including pointing with white cement mortar 1:2 (1 white cement: 2 marble dust) with an admixture of pigment to match the marble shade (To be secured to the backing by means of cramps, which shall be paid for separately). (Area of slabs over 0.50 sqm.) 11.21.1 Makrana white second quality. 11.21.2 Raj Nagar plain. 11.21.3 Agaria White/Morgarh 11.21.4 Katni marble 11.21.5 Black Zebra. 11.21.6 Udaipur / Baroda green marble 11.21.7 Pink plain marble. 11.21.8 Jaisalmer Yellow 486 11.22 Providing and fixing 18mm thick gang saw cut mirror polished (premoulded and prepolished) machine cut for kitchen platforms, vanity counters, window sills , facias and similar locations of required size of approved shade, colour and texture laid over 20mm thick base cement mortar 1:4 (1 cement : 4 sand) with joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing moulding and polishing to edge to give high gloss finish wherever required etc. complete at all levels. Samples approved by Engineer-in- Charge. 11.22.1 Raj Nagar plain/White Marble/Udaipur Green Marble /Zebra black 11.22.2.1 Granite fine grained dark crystal of other colours and various patterns 11.22.2.2 Granite coarse grained light black/ light red/white with crystal of other colours and various patterns 11.22.2.3 Granite grey/pink/brown with various patterns 11.22.3 Cuddpah stone 487 11.23 Extra for prefinished nosing to treads of steps of marble stone. 488 11.24 Extra for marble stone flooring in treads of steps and risers using single length upto 2.00 metre. 489 11.25 Extra for prefinished grooves to treads of steps of granite stone 490 11.26 Providing and laying machine cut, mirror polished, Italian Marble stone (18 mm thick Italian Marble stone slab, Perlato, Rosso erona, Fire Red or Dark Emperadore etc.)work in flooring laid over 20 mm (average) thick base of cement mortar 1:4 (1 cement: 4 sand) laid and jointed with white cement slurry @ 4.4 kg/sqm including pointing with white cement slurry mixed with pigment to match the marble shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. 491 11.27 Providing and fixing machine cut, mirror / eggshell polished , Marble stone work 18 mm thick Italian Marble stone slab,Perlato, Rosso verona, Fire Red or Dark Emperadore etc. for wall lining (veneer work) including dado, skirting, risers of steps etc. thick cement mortar 1:3 (1 cement : 3 sand) laid and jointed with white cement slurry @ 3.3 kg/sqm including pointing with white cement slurry admixed with pigment of matching shade, including rubbing, curing, polishing etc. all complete as per Architectural drawings, and as directed by the Engineer-in-Charge. 492 11.28 Italian marble flooring in required design and patterns 11.28.1 Providing and laying machine cut, mirror polished Italian Marble stone 18 mm thick Italian Marble stone slab,Perlato, Rosso verona, Fire Red or Dark Emperadoreetc flooring, in required design (Simple geometrical, abstract etc.) and in patterns in combination with Italian marble stones of different colours, shades and finished surface texture etc., in linear portions of the building, all complete as per the architectural drawings, with 18 mm thick stone slab laid over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 sand) laid and jointed with white cement slurry @ 4.4 kg/sqm including pointing with white cement slurry admixed with pigment to match the marble shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.Note – This item shall be executed only after the prior approval of Chief Engineer. 493 11.29 Granite work gang saw cut (polished and machine cut) of thickness 18mm for wall lining (veneer work), backing filled with a grout of average 12 mm thick in cement mortar 1:3 (1 cement: 3 sand) including pointing with white cement mortar 1:2 (1 white cement: 2 marble dust) with an admixture of pigment to match the marble shade: (To be secured to the backing by means of cramps, which shall be paid for separately). 111.29.1 Area of slab over 0.50 sqm 11.29.1.1 Fine grained granite dark Black/dark Red/ White or equivalent with self design/ pattern/crystals of other colors of glitter 11.29.1.2 Coarse grained granite light Black/light Red/ off White or equivalent with self design/ pattern/crystals of other colors of glitter 11.29.1.3 Gray/Pink/Brown or equivalent with various patterns 11.29.2 Area of slab upto 0.50 sqm 11.29.2.1 Fine grained granite dark Black/dark Red/ White or equivalent with self design/ pattern/crystals of other colors of glitter 11.29.2.2 Coarse grained granite dark Black/dark Red/ White or equivalent with self design/ pattern/crystals of other colors of glitter 11.29.2.3 Gray/Pink/Brown or equivalent with various patterns 494 11.30 Providing and laying gang saw cut 18 mm thick, mirror polished premoulded (wherever required) and pre polished machine cut granite stonework in flooring of required size shape of approved shade, color and texture in flooring laid over 20 mm thick base of cement mortar 1:4 (1 Cement: 4 sand) including grouting the joints with white cement mixed with matching pigments epoxy touch ups etc. complete as per direction of Engineer-in-Charge. 11.30.1 Area of slab over 0.50 sqm 11.30.1.1 Fine grained granite dark Black/dark Red/ White or equivalent with self design/ pattern/crystals of other colors of glitter 11.30.1.2 Coarse grained granite light Black/light Red/ off White or equivalent with self design/ pattern/crystals of other colors of glitter 11.30.1.3 Gray/Pink/Brown or equivalent with various patterns 11.90.2 Area of slab upto 0.50 sqm 11.30.2.1 Fine grained granite dark Black/dark Red/ White or equivalent with self design/ pattern/crystals of other colors of glitter 11.30.2.2 Coarsegrained granite dark Black/dark Red/ White or equivalent with self design/ pattern/crystals of other colors of glitter 11.30.2.3 Gray/Pink/Brown or equivalent with various patterns 492 11.31 Providing and laying gang saw cut 30 mm thick, mirror polished pre moulded and pre polished machine cut granite stone of required size and shape of approved shade, colour and texture in footpath, flooring in road side plazas and similar locations, laid over 20mm thick base of cement mortar 1:4 (1cement: 4 sand) including grouting the joints with white cement mixed with matching pigment, epoxy touch ups etc. complete as per direction of Engineer-in-Charge. (area of slab more than 0.50 sqm) 11.31.1 Fine grained granite dark Black/dark Red/ White or equivalent with self design/ pattern/crystals of other colors of glitter 11.31.2 Coarse grained granite light Black/light Red/ off White or equivalent with self design/ pattern/crystals of other colors of glitter 11.31.3 Gray/Pink/Brown or equivalent with various patterns 495 11.32 Deduct for not polishing granite flooring (item no 11.29 & 11.30) 496 11.33 Providing and laying Granite stone flooring in required design and patterns in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry admixed with pigment of matching shade including rubbing, curing and polishing and as directed by the Engineer-in-Charge Granite stone slab Dark Black. Dark Red, White or equivalent, 11.33.1 Flamed Finish Polish 11.33.2 Leather Finish Polish 497 11.34 Granite stone work 18mm thick of any colour in riser of steps, skirting, dado and pillars laid on 12 mm average thick cement mortar 1:3 (1 cement:3 sand) and jointed with white cement slurry mixed with pigment to match the shade of slab. 498 11.35 Providing and fixing 10x10x7.50 cm Granite stone block hand cut andchisel dressed on top, for paving in floors, drains etc. laid over 20mm thick base mortar 1:4 (1cement:4 sand) with joints 10mm wide filled with same mortar mixed with matching pigment including ruled pointing etc. complete as per direction of engineer-in charge. 499 11.36 Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 sand) 25 mm thick.(Area of slab to be over 0.25 sqm) 500 11.37 Deduction for using 20 mm thick slab instead of 25 mm thick slab of kota stone in item no 11.35 501 11.38 Kota stone slabs in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. 502 11.38.1 10-12 mm thick 11.38.2 20 mm thick 503 11.39 Kota stone slab (area less than 0.5 sqm) rough chiseled dressed average 40 mm thick flooring for parking and open area of thickness over 20 mm (average) thick base laid over and jointed with grey cement slurry complete with base of cement mortar 1:4 (1 Cement : 4 Sand) 504 11.40 Providing edge moulding to 18mm thick marble stone counters, Vanities, window sills etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. 11.40.1 Marble work 11.40.2 Granite work. 505 11.41 Extra for fixing marble /granite stone over and above corresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive including cleaning etc. complete. 506 11.42 Extra for providing opening of required size and shape for wash basins/ kitchen sink in kitchen platform, vanity counters and similar location in marble/Granite/stone work including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. 507 11.43 Mirror polishing on marble work/Granite work/stone work wherever required to give high gloss finish complete. 508 11.44 Fine dressed stone flooring over 20 mm (average) thick base of cement mortar 1:5 (1cement : 5 sand) with joints finished flush. 11.44.1 Red sand stone 11.44.2 White sand stone 11.44.3 Grey lime stone 11.44.4 Kota stone 509 11.45 40 mm thick fine dressed stone flooring over 20 mm (average) thick base of cement mortar 1:5 (1 cement : 5 sand) including pointing with cement mortar 1:2 (1 cement : 2 sand) with an admixture of pigment to match the shade of stone. 11.45.1 Red sand stone 11.45.2 White sand stone 510 11.46 40 mm thick machine rubbed stone flooring over 20 mm (average) thick base of cement mortar 1:5 (1 cement :5 sand) with joints 3mm thick, side buttered with cement mortar 1:2 (1 cement : 2 sand) mixed with pigment to match the shade of stone and pointing with same mortar 11.46.1 Red sand stone 11.46.2 White sand stone 511 11.47 Extra for pre finished nosing in treads of steps of Kota stone/ sand stone slab. 512 11.48 Extra for Kota stone/ sand stone in treads of steps and risers using single length upto 1.05 metre. 513 11.49 Providing and laying Ceramic glazed floor tiles 300x300 mm or more (having thickness 6 to 7mm) of 1st quality conforming to IS : 15622 of approved make in any colours and shade laid on 20 mm thick Cement Mortar 1:4 (1 Cement : 4 sand) including pointing the joints with white cement and matching pigment etc., complete. 514 11.50 Providing and fixing Ceramic glazed wall tiles 300x450 mm or more (having thickness 6 to 7 mm) of 1st quality conforming to IS: 15622 of approved make in all Colours& shades, except burgundy, bottle green, black laid on 12mm thick bed of Cement Mortar 1:3 (1 Cement: 3 sand)preprad same day when mortar is still green jointed with grey cement slurry @3.3 kg per sqm including pointing the joints with white cement and matching pigments etc., complete. 515 11.51 Providing and laying rectified Glazed Ceramic floor tiles 300x300 mm or more (having thickness 9 to 10mm) of 1st quality conforming to IS : 15622 of approved make in all colours white, ivory, grey, fume red brown laid on 20mm thick cement mortar 1:4 (1 Cement : 4 sand) including grouting the joints with white cement and matching pigments etc., complete. 516 11.52 Providing and laying rectified Glazed Ceramic wall tiles 300x450 mm or more (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in all colours white, ivory, grey, fume red brown laid on 12 mm thick cement mortar 1:3 (1 Cement : 3 sand) including grouting the joints with white cement and matching pigments etc., complete. 517 11.53 Providing and laying Antiskid floor tiles of any sizes, 12 mm thickness with water absorption less than 0.08% and conforming to IS:15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 sand) including grouting the joints with white cement with matching pigments etc., complete. 518 11.54 Deduct for not grouting the joints with white cement and matching pigment in the items of fixing of vitrified tiles. 519 11.55 Deduct for not using 20mm thick cement mortar 1:4 (1 cement: 4 sand) bedding in laying of floor tiles. 520 11.56 Fixing glazed/ Ceramic/Rectified/ Vitrified floor tiles with cement based high polymer modified quick-set tile adhesive (Water based) conforming to IS: 15477, in average 3mm thickness. 521 11.57 Providing and laying tactile tile (for vision impaired persons as per standards) of size 300x300x9.8mm having water absorption less than 0.05% and conforming to IS: 15622 of approved make in all colours and shades for outdoor floors such as footpath, court yard, multi modals location etc., laid on 20mm thick base of cement mortar 1:4 (1cement : 4 sand) in all shapes and patterns including grouting the joints with white cement mixed with matching pigments etc. complete as per direction of Engineer-in-Charge. 522 11.58 Providing and fixing Glass mosaic tiles at finished plain wall surface of size 20 mm x 20 mm x 4 mm in all colour, design, fixing in customize design as per direction of Engineer-in- Charge. The glass mosaic tiles to be fixed on the wall surface with the help of approved adhesive applied at the rate of 2.5 kg per sqm and grouting of the same. The rate is inclusive of all operation, material and required pattern approved by Engineer-in-Charge: 523 11.59 Providing and laying 500x500x40mm thick Turf paver on 150mm thick sub grade of compacted bed of 20mm nominal size stone aggregate and base course with 50mm thick sand and filling joints with sand including spreading, well ramming, consolidating and finishing smooth etc. all complete as per direction of Engineer- in-charge. 524 11.60 Providing and fixing 10mm thick acid and/ or alkali resistant tiles of approved make and colour using acid and/ or alkali resisting mortar bedding and joints filled with acid and/ or alkali resisting cement as per IS : 4457 complete as per the direction of Engineer-in- Charge. 525 11.60.1 In flooring on a bed of 10 mm thick mortar 1:4 (1 acid proof cement: 4 sand)Acid and alkali resistant tile. 526 11.60.2 In dado/skirting on 12 mm thick mortar 1:4 (1 acid proof cement: 4 sand).Acid and alkali resistant tile. 527 11.61 8 mm thick.stones Tile work in skirting, risers of steps and dado (upto 2 m height) over 12 mm thick bed of cement mortar 1:3 (1 cement :3 sand) and jointed with grey cement slurry @ 3.3 kg/sqm including pointing in white cement mixed with pigment of matching shade complete. 11.61.1 Marble tiles (polished) Raj Nagar. 11.61.2 Granite tile of any colour /shade 528 11.62 Providing and fixing cramps of required size and shape in RCC/ CC /Stone/ Brick masonry backing with cement mortar 1:2 ( 1 cement :2 sand) including drilling necessary hole in stones and embedding the cramp in the hole (fastener to be paid separately). 11.62.1 Gunmetal cramps. 11.62.2 Stainless steel cramps. 529 11.63 Providing and fixing expansion hold fasteners of wedge expansion type on C.C. / R.C.C./ Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. 11.63.1 Fastener with threaded dia 6 mm. 11.63.2 Fastener with threaded dia 10 mm. 11.63.3 Fastener with threaded dia 12 mm. 530 11.64 Providing and fixing stone slab table rubbed on both faces edges rounded and polished of size as required and 1.8 cm thick fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement: 2 sand: 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in- charge and finished smooth. 11.64.1 White Agaria Marble Stone. 11.64.2 Granite Stone of approved shade. 531 11.65 Providing and fixing removable raised/false access flooring with system and its components of approved make for different plenum height with possible height adjustment upto 50 mm, comprising of modular load bearing floor panels supported on G.I. rectangular stinger frame work and and Surface flatness within 0.75mm.The panel is to withstand a Concentrated Load of 363 kgs applied on area 25mm x 25mm without collapse in the centre of the panel which is placed on four steel blocks. The panel will withstand and Uniformly Distributed Load (UDL) minimum 1250 kg/sqm and an impact load of 50kg all complete as per the approved manufacturers specification and as per the direction of Engineer- in-charge. All specification must be printed on the side of the panel to ensure the quality of the product. 11.65.1 300 mm Finished Floor Height (FFH) 11.65.2 450 mm Finished Floor Height (FFH). 532 11.66 Providing and laying factory made machine pressed precast cement concrete interlocking paver block of any shape and size conforming to IS:15658- 2006 and ISI marked of 60 mm thickness, M-30 grade with grey cement and pigment all as specified. Made by block making machine with strong vibratory compaction, laid in required colour and pattern over and including 50mm thick compacted bed of stone dust, filling the joints with sand etc. all complete as per the direction of Engineer-in-Charge. 533 11.67 Providing Epoxy flooring self leveling type on strong base in desired colour/design as approved by Engineer-in-Charge. Resin for epoxy is to be of floor grade type i/c appropriate hardner and filler material. with 5 year defect liability period (This item is to be used only for operation theaters in hospitals) 11.67.1 1 mm thick 11.67.2 2 mm thick 11.67.3 3 mm thick 534 11.68 Providing and fixing acoustic PVC (Poly Vinyl Flooring) EN (European Standard) over fiberglass mat PVC foam backing (EN 14904), total thickness is 3.25mm (EN 428/EN 427), wear layer is 0.85 mm thick (EN 429), anti-bacterial and anti-fungus surface treatment , chemical resistance test qualified (EN-423)-high resistance, thermal and underfloor heating test qualified (EN12524) - all vinyl sheets must be linked crosswise with a continuous copper strip and finally connected to earth for grounding electrostatic electrical charges. Suitable and slip resistant. Recommended to use in area like Lecturer room, Conference room, Kids area, School, colleges, Residential and all commercial official scope etc. 535 11.69 Providing and fixing 2 mm thick heterogeneous PVC (poly vinyl flooring) EN (European Standard) with wear layer is 0.55mm thick of PVC, total weight is 2300 g/m2 approx. PUR (polyurethane reinforced), residual indentation approx.0.05 mm, castor wheel test qualified, dimensional stability ≤0.10%, static electrical charge .The floor finish should termite free at the room perimeter passing over a concealed cove forming and continuing up on the wall upto100mm. Recommended to use in area like Patient rooms , Doctor room Lecturer room, Kids area, School, Colleges, Residential and all commercial official scope etc. 536 11.70 Providing and fixing 8mm and above thick laminated (wooden flooring) of AC4 and above grade product of approved made out of core high density fibre board (HDF), surface layer shall be high preasure laminated treated for abrasion, scratch, moisture protection, flame protection U.V resistant, layer of acrylic resin, aluminium oxide or similer layer having above properties, backing under layer on min 2 mm thickness shall provide as sound absorbent and moisture protection layer, The seamless impregenated decorative layer of specified size, design, colour and pettern, all bonded together under high temperature and pressure with eco-friendly. The material shall be applicable warranty formaldehyde free, eco- friendly and fully recyclable (eco-freindly) and matching shed and excluding quantity of skirting and profile. 537 11.71 Brick on edge flooring with bricks of class designation 7.5 on a bed of 12 mm cement mortar, 1:6 (1 cement : 6 sand) including filling the joints with same mortar, with common burntclay non modular bricks 11.71.1 100 mm thick 11.71.2 200mm thick 538 11.72 Providing and laying factory made chamfered edge Cement Concrete paver blocks of required colour strength, thickness pattern, surface texture (smooth/rough) and size/shape, conforming to 15658-2006 IS marked made by table vibratory method using PU mould, laid in required colour and pattern over 0.30 mm with courtyards, porch with M 15 cement concrete in footpath, parks, lawns, drive ways or light traffic parking etc. complete as per manufacturers specifications and direction of Engineer-in-Charge. 11.72.1 80 mm thick C.C. paver block of M-35 grade 11.72.2 60 mm thick C.C. paver block of M-35 grade 11.72.3 60 mm thick C.C. paver block of M-30 grade 539 11.73 Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineer-in- Charge). 540 11.74 Providing and fixing at or near ground level factory made RCC pavement slab of M-30 grade of size 450x450x50 mm, including reinforcement with 6 mm dia M.S. bars 4 nos on each side(top & bottom), including setting in position in footpath to the required level and line over a bed of 20 mm average thick cement mortar 1:5 (1 cement : 5 sand), having joint thickness not more than 5mm except on curve, including filling of joints with same cement mortar and making grooves etc. complete as per direction of Engineer-in-Charge. 541 11.75 Providing and fixing 16mm thick gang saw cut mirror polished premoulded and prepolished machine cut Granite of approved shade, colour and texture of Granite Door frame. in cement mortar 1:3 (1 cement :3 sand) Including rubbing, curing, moulding and polishing edges to give high glossy finish and drilling of hole for fixing stainless steel hings, aldrop, towerboltetc complete at all levels as per instruction of Engineer-in-Charge. 11.75.1 Granite Door frame for 100mm thick wall Thickness. 11.75.2 Granite Door frame for 200mm thick wall Thickness. 542 11.76 Providing and laying vitrified floor tiles (without soluble salt) or printed (with soluble salt) Nano polished (Glossy finish) in different sizes with water absorption less than 0.05% and conforming to IS:15622 of approved make in all colours& shades, 1st quality/ premium quality in flooring laid on 20mm thick cement mortar 1:4 (1cement :4sand) including grouting the joints with white cement and matching pigments etc. complete 11.76.1 Plain ivory light shade : Size 600X600mm thickness 9-10mm 11.76.2 Dark shade (terracotta) : Size 600X600mm thickness 9-10mm 543 11.77 Providing and laying vitrified floor tiles (without soluble salt) or printed (with soluble salt) Nano polished (Glossy finish) in different sizes with water absorption less than 0.05% and conforming to IS:15622 of approved make in all colours& shades, 1st quality/ premium quality in skirting laid on 12mm thick cement mortar 1:4(1cement :4sand) including grouting the joints with white cement and matching pigments etc. complete 11. 77.1 Plain ivory light shade : Size 600X600mm thickness 9-10mm 11. 77.2 Dark shade (terracotta) : Size 600X600mm thickness 9-10mm 544 11.78 Providing and laying vitrified floor tiles Multi/Double charged (Minimum top layer thickness 2.0mm) Neno Polished self design, in different size with water absorption less than 0.05% and conforming to IS:15622 of approved make in all colours& shades, quality/ premium quality in flooring laid on 12mm thick cement mortar 1:4(1cement :4sand) including grouting the joints with white cement and matching pigments etc. complete 11. 78.1 In light shade glossy/ rustic /stain finished 11. 78.1.1 Size 600X600 mm thickness 9-10 mm 11. 78.1.2 Size 800X800mm thickness 11-12mm 11. 78.1.3 Size 800X1200 mm thickness 11-12mm 11. 78.2 In dark shade glossy/ rustic /stain finished 11. 78.2.1 (a) Size 600X600 mm thickness 9-10 mm 11. 78.2.2 (b) Size 800X800mm thickness 11-12mm 11. 78.2.3 (c) Size 800X1200 mm thickness 11-12mm 545 11.79 Providing and laying vitrified floor tiles Multi/Double charged (Minimum top layer thickness 2.0mm) Neno Polished self design, in different size with water absorption less than 0.05% and conforming to IS:15622 of approved make in all colours& shades, 1st quality/ premium quality in skirting laid on 12mm thick cement mortar 1:4(1cement :4sand) including grouting the joints with white cement and matching pigments etc. complete 11. 79.1 In light shade glossy/ rustic /stain finished 11. 79.1.1 (a) Size 600X600 mm thickness 9-10 mm 11. 79.1.2 (b) Size 800X800mm thickness 11-12mm 11. 79.1.3 (c) Size 800X1200 mm thickness 11-12mm 11. 79.2 In dark shade glossy/rustic/stain finished 11. 79.2.1 (a) Size 600X600 mm thickness 9-10 mm 11. 79.2.2 (b) Size 800X800mm thickness 11-12mm 11. 79.2.3 (c) Size 800X1200 mm thickness 11-12mm 546 11.80 Providing and laying vitrified floor-tiles Full Body Design Homogenous Body matt/rustic finish in different size with water absorption less than 0.05% and conforming to IS:15622 of approved make in all colours& shades, 1st quality/ premium quality in flooring laid on 20mm thick cement mortar 1:4(1cement :4sand) including grouting the joints with white cement and matching pigments etc. complete 11. 80.1 In light colour and shades as ivory, beige blanco, grey etc. 11. 80.1.1 (a) Size 300X300 mm thickness 9-10 mm 11. 80.1.2 (b) Size 600X600mm thickness 9-10mm 11. 80.1.3 (c) Size 600X600 mm thickness 11-12mm (to be used heavy duty indoor areas of non residencial buildings only such as schools, hostels, libraries hospitals, institutions, offices etc.) 11. 80.2 In dark colour and shade etc. 11. 80.2.1 (a) Size 300X300 mm thickness 9-10 mm 11. 80.2.2 (b) Size 600X600mm thickness 9-10mm 11. 80.2.3 (c) Size 600X600 mm thickness 11-12mm (to be used in heavy duty indoor areas of non residencial buildings only such as schools, hostels, libraries hospitals, institutions, offices etc.) 547 11.81 Providing and laying vitrified floor-tiles Full Body Design Homogenous Body matt/rustic finish in different size with water absorption less than 0.05% and conforming to IS:15622 of approved make in all colours& shades, 1st quality/ premium quality in skirting, riser laid on 12mm thick cement mortar 1:4(1cement :4sand) including grouting the joints with white cement and matching pigments etc. complete 11. 81.1 In light colour and shades as ivory, beige blanco, grey etc. 11. 81.1.1 (a) Size 300X300 mm thickness 9-10 mm 11. 81.1.2 (b) Size 600X600mm thickness 9-10mm 11. 81.2 In dark colour and shades etc. 11. 81.2.1 (a) Size 300X300 mm thickness 9-10 mm 11. 81.2.2 (b) Size 600X600mm thickness 9-10mm 548 11.82 Providing and laying digital print random design(PGVT)/(GVT) vitrified tiles in different sizes with water absorption less than 0.05% and conforming to IS:15622 of approved make in all colours& shades, 1st quality/ premium quality including grouting the joints with white cement and matching pigments etc. complete 11. 82.1 For floor glossy/ rustic /stain/matt finished laid on 20mm thick cement mortar 1:4 (1 cement:4sand) 11. 82.1.1 Size 600X600 mm thickness 9-10 mm 11. 82.1.2 Size 800X800mm thickness 11-12mm 11.82.1.3 Size 800X1600 mm thickness 11-12mm 11.82.1.4 Size 1000X1000 mm thickness 11-12mm 11. 82.1.5 Size 600X1200 mm thickness 11-12mm 11. 82.1.6 Size 800X1200 mm thickness 11-12mm 11. 82.1.7 Size 1200X1200 mm thickness 11-12mm 11.82.1.8 Size 1200X1800 mm thickness 11-12mm 11.82.1.9 Size 1200X2400 mm thickness 11-12mm 11. 82.2 For wall stain / rustic finished laid on 12mm thick cement mortar 1:3 (1 cement:3sand) prepared same day when mortar is still green i.e.within 6 hours, Size 300X600 mm thickness 9-10 mm 11. 82.3 For wall polished / Glossy finished laid on 12mm thick cement mortar 1:3 (1 cement:3sand) prepared same day when mortar is still green i.e. within 6 hours, Size 300X600 mm thickness 9-10 mm 549 11.83 Providing and laying digital print random design(PGVT)/(GVT) vitrified tiles in different sizes with water absorption less than 0.05% and conforming to IS:15622 of approved make in all colours& shades, 1st quality / premium in skirting, riser laid our 12mm thick cement mortar 113 including grouting the joints with white cement and matching pigments etc. complete 11. 83.1 For skirting, risers etc. glossy/ rustic /stain/matt finished in all colours and shades 11. 83.1.1 Size 600X600 mm thickness 9-10 mm 11. 83.1.2 Size 800X800mm thickness 11-12mm 11. 83.1.3 Size 600X1200 mm thickness 11-12mm 11. 83.1.4 Size 800X1200 mm thickness 11-12mm 550 11.84 Granite work gang saw cut (polished machine cut) of thickness 12 mm for wall lining, skirting, risers of steps and dado (veneer work), back filling with a grout of average 12 mm thick in cement mortar 1:3 (1 Cement: 3 sand) including pointing with white cement mortar 1:2 (1 white cement: 2 marble dust) with an admixture of pigment to match the marble shade: (To be secured to the beaching by means of cramps, which shall be paid for separately). 11. 84.1 Area of tiles not less 0.18 sqm 11. 84.1.1 Fine granite dark Black/dark Red/ White with self design/ pattern/crystals of other colors of glitter 11. 84.1.2 Course granite light Black/light Red/ off White with crystals of other colors and various patterns 11. 84.1.3 Gray/Pink/Brown with various patterns 551 11.85 Providing and laying gang saw cut 12mm thick, mirror polished pre moulded (wherever required) and pre polished machine cut granite stone of required size and shape of approved shade, colour and texture in flooring laid over 20mm thick base of cemnt mortar 1:4(1cement:4sand) including grouting the joints with white cement mixed with matching pigments, epoxy touch ups etc. complete as per direction of Engineer-in-Charge. 11. 85.1 Area of tiles not less 0.18 sqm 11. 85.1.1 Fine grained granite dark Black/dark Red/ White with self design/ pattern/crystals of other colors of glitter 11. 85.1.2 Coarse grained granite light Black/light Red/ off White with crystals of other colors and various patterns 11. 85.1.3 Gray/Pink/Brown with various patterns 552 11. 86 Providing and fixing artificial synthetic green long and fine yarns grass, UV/water resistant with SBR latex backing eco-friendly durable high density 100 % PP ( Poly Poplin ) anti UV fiber.denier 12000 dtex, stich rate 18 stiches per 10cm, stich density 16800 stiches/m2, tufted weight 1830g/sqm approx. 11. 86.1 Roll size will be 25.00m X 2.00m (25mm thick)- weight 150kg- per roll. 11. 86.2 Roll size will be 25.00m X 2.00m (40mm thick)- weight 180kg- per roll. 553 11.87 Providing and fixing laminated (engineered wooden flooring) of suitable thickness 10-14 mm of suitable grade category product of approved made out of core high density fibre board (HDF) &other component it treated for abrasion ,scratch ,moisture protection, flame protection,U.V resistant. backing with eco- friendly resins specified by the manufacturer .The material shall be applicable warranty formaldehyde free, eco friendly, highly recommended for high traffic area and fully recyclable and matching shed and excluding quantity of skirting and profile. 554 11.88 Providing and fixing single layer homogeneous (solid wooden flooring) of suitable thickness 14 - 18 mm of suitable grade category product of scratch protection, moisture protection, flame protection U.V. resistant, backing under layer on min 2 mm thickness The material shall be applicable warranty formaldehyde free, eco friendly ,highly recommended for high traffic area and fully recyclable and matching shade and excluding quantity of skirting and profile. 555 11.89 Providing and fixing tuffed 1/10” loop pile (carpet tile / Carpet). EN (Euorpean Standard) size 50cm x 50cm /roll Size of total thickness 5.5 mm and above with total mass of 4100g/m2approx and with polyester fleece primary backing with standard dimensional stability with impact sound / noise reduction and recommended for high traffic acoustical area. 556 11.90 Providing and fixing spc (stone plastic composite) virgin pvc water resistant proof vinyl flooring with a thickness between 4 to 8mmuv coated layer with a wear layer of 0.3 to 0.80mm with a SPC core layer of 2.00 to 5.00 mm with a SOP of heat resistant, voc free, easy to cut, anti microbial protection in the form of tiles, planks helpful in environmental of profection health. 557 11.91 Providing and laying pre mirror polished/ pre polished fine grain machine cut sand stone tile flooring 20mm thick (hardness should not be less than 7 and water absorption should not be more than 0.3%) of required size and shape of approved shade, flooring in plazas open staircase and similar locations, laid over 20 mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) including grouting the joint with white cement mix with matching pigment etc. complete as per direction of Engineer-in-Charge. 11. 91.1 300x300mm 11. 91.2 400x400mm 11. 91.3 600x600mm 558 11.92 Providing and laying pre mirror polished/ pre polished fine grain machine cut sand stone slab flooring 20mm thick (hardness should not be less than 7 and water absorption should not be more than 0.3%) of required size of area more then .50 sqm and shape of approved shade, flooring in plazas open staircase and similar locations, laid over 20mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) including grouting the joint with cement mix matching pigment etc. complete as per direction of Engineer -in-Charge. 559 12.1 Providing corrugated G.S. Sheet roofing including vertical/ curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead and including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete upto any pitch in horizontal/ vertical or curved surfaces) excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 12.1.1 1.00mm thick with zinc coating not less than 275gm/m² 12.1.2 0.80mm thick with zinc coating not less than 275gm/m² 12.1.3 0.63 mm thick with zinc coating not less than 275gm/m² 560 12.2 Straight cutting in G.S. sheet of any thickness roofing for making opening of area exceeding 40 sq. decimetre for chimney stacks, sky light etc. 561 12.3 Extra for circular cutting in C.G.S. sheet of any thickness roofing for making opening of area exceeding 40 square decimetre : 562 12.4 Providing ridges or hips of width 60 cm over all width plain G.S. sheet fixed with polymer coated J or L hooks, bolts and nuts 8 mm dia. G.I. limpet and bitumen washers complete. 12.4.1 0.80mm thick with zinc coating not less than 275gm/m² 12.4.2 0.63mm thick with zinc coating not less than 275gm/m² 563 12.5 Providing valleys of 90cm wide overall in plain G.S. sheet fixed with polymer coated J or L hooks, bolts and nuts 8mm dia. G.I. limpet and bitumen washers complete. 1.60 mm thick with zinc coating not less than 350gm/m² 564 12.6 Providing and Fixing of 40 cm over all width plain, G.S. sheet fixed with polymer coated J or L hooks, bolts and nuts, G.I. limpet and bitumen washer complete, bent to shape and fixed in wall with cement mortar 1:3 (1cement : 3 sand). 1.00mm thick with zinc coating not less than 275gm/m² 565 12.7 Providing and fixing 15 cm wide 45 cm over all semicircular plain G.S. sheet gutter with iron brackets 40x3mm size, bolts, nuts and washers etc. including making necessary connections with rain water pipes complete. 12.7.1 0.80mm thick with zinc coating not less than 275gm/m² 12.7.2 0.63mm thick with zinc coating not less than 275gm/m² 566 12.8 Providing reinforced by organic fibres and/or inorganic synthetic fibres cement 6 mm thick corrugated sheets (as per IS: 14871) roofing up to any pitch and fixing with polymer coated J, or L hooks, bolts and nuts 8 mm dia.G.I. plain and bitumen washers or with self drilling fastener and EPDM washers etc. complete (excluding the cost of purlins, rafters and trusses), including cutting sheets to size and shape wherever required. 567 12.9 Extra for straight cutting in reinforced by organic fibres and/or inorganic synthetic fibres cement corrugated, semi corrugated 6 mm thick sheet roofing for making openings of area exceeding 40 square decimeter for chimney stacks, skylights etc.. 568 12.10 Extra for circular cutting in reinforced by organic fibres and/or inorganic synthetic fibres cement corrugated/ semi corrugated 6 mm thick sheet roofing for making openings of area exceeding 40 square decimeter. 569 12.11 Extra for providing and fixing wind ties of 40x 6 mm flat iron section. 570 12.12 Providing and fixing ridges and hips in fibre cement reinforced by organic fibres and/or inorganic synthetic fibres roofing with suitable fixing accessories or self drilling fastener and EPDM washer etc. complete. 12.12.1 Corrugated serrated adjustable ridges 12.12.2 Plain wing adjustable ridges 12.12.3 Close fitting adjustable ridges 12.12.4 Unserrated adjustable hips 571 12.13 Providing and fixing fibre cement reinforced by organic fibres and/or inorganic synthetic fibres roofing accessories in all colours with polymer coated J or L hooks, bolts and nuts and or G.I. seam bolts and nuts, G.I. plain and bitumen washers or with self drilling fastener and EPDM washer etc. complete: 12.13.1 Corrugated apron pieces 12.13.2 Eaves filler pieces 12.13.3 North light curves 12.13.4 ventilator curves 12.13.5 Barge boards 12.13.6 Ridge finials 12.13.7 Special north light curves 12.13.8 S type louvers 572 12.14 Providing flat iron brackets 50x3mm size with necessary bolts, nuts washers etc. for fixing G.S. sheets gutters with purlins. 573 12.15 Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm + 0.05 %, total coated thickness with zinc coating 120 gsm as per IS:277 in 240 mpa steel grade, 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches while transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self-drilling /self-tapping screws of size (5.5x 55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 574 12.16 Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm + 0.05 % total coated thickness, Zinc coating 120gsm as per IS: 277 in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self-drilling/ self- tapping screws complete : 12.16.1 Ridges plain (500 - 600mm). 12.16.2 Flashings/ Aprons.( Upto 600 mm) 12.16.3 North light curves. 12.16.4 Barge board (Upto 300 mm) 12.16.5 Crimp curve 12.16.6 Gutter. (600 mm over all girth) 575 12.17 Providing & fixing UV stabilised fiberglass reinforced plastic sheet roofing up to any pitch, including fixing with polymer coated J or L hooks, bolts & nuts 8mm dia. G.I plain/bitumen washers complete but excluding the cost of purlins, rafters, trusses etc. The sheets shall be manufactured out of 2400 TEX panel rovigs incorporating minimum 0.3% ultra-violet stabiliser in resin system under approximately 2400 psi and hot cured. They shall be of uniform pigmentation and thickness without air pockets and shall conform to IS 10192 and IS 12866.The sheets shall be opaque or translucent, clear or pigmented, textured or smooth as specified. 12.17.1 2mm thick corrugated (2.5 or 4.2 or 6) or step-down (2or 3or 6) as specified. 12.17.2 2mm thick flat. 576 12.18 Providing and Fixing of sky lights consisting of Multi cell/tight cell Polycarbonate Panel System of approved colour, 16 mm thick (minimum) having uniform in color with an integral Tight-Cell core constructed not to exceed 4mmx4mm in a cross section, involved such as bolts nuts and screws etc. and labour for cutting bending to required profile, necessary scaffolding, hoisting in position etc. for proper completion of the work etc. complete as per specification drawings and direction of Engineer in charge. Finished surface area of roofing fixed over steel tubular structure shall be measured for payment. MS tabular frame work shall be measured separately for payment. 12.18.1 10mm thick 12.18.2 16mm thick 577 12.19 Providing sand stone slab 40 to 50 mm thick for roofing and laying them in cement mortar 1 : 4 (1 cement : 4 sand) over wooden karries or R.C.C. battens or structural steel sections (Karries or battens or structural steel sections to be paid separately) including pointing the ceiling joints with cement mortar 1:3 (1 cement : 3 sand ) complete : 12.19.1 Red sand stone slab 12.19.2 White sand stone slab : 578 12.20 Painting top of roofs with residual type petroleum bitumen of grade VG 10 of approved quality @ 17kg per 10 sqm impregnated with a coat of sand at 60 cum per 10sqm including cleaning the slab surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil complete : 579 12.21 Providing and applying two coats of High Albedo paint having minimum Solar Reflective Index (SRI) 108 (with solar reflectance and thermal emittance tested as per ASTM) C 1549 and ASTM C 1371 respectively), VOC less than 10 cc/gm. The coating thickness and the methodology of application shall be strictly as per manufacturers specifications and as approved by engineer In charge. Surface preparation includes cleaning with metal wire brush to remove all dust, fungus etc., and washing with water all complete. The contractor shall give guarantee for the performance of SRI and also the durability of coating, all complete as per direction of Engineer-in-charge. 580 12.22 Providing and fixing Heat Resistant Terrace Tiles (300 mm x 300 mm x 20 mm) with SRI (solar refractive index) > 78, solar reflection >0.70 and initial emittance >0.75 on waterproof and sloped surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1:4 (1 cement : 4 sand) and grouting the joints with mix of white cement and marble powder in ratio of 1:1, including rubbing and polishing of the surface upto 3 cuts complete, including providing skirting upto 150 mm height along the parapet walls in the same manner. 581 12.23 Providing and laying pressed clay tiles (as per approved pattern 20 mm nominal thickness and of approved size) on roofs jointed with cement mortar 1:4 (1 cement : 4 sand) mixed with 2% integral water proofing compound laid over a bed of 20 mm thick cement mortar 1:4 (1 cement : 4 sand) and finished neat complete. 582 12.24 Providing and fixing on roof pressed clay tile (Mangalore tile) 20 mm nominal thickness and of approved size and as per approved pattern on steel frame work complete (steel frame work to be paid separately) 583 12.25 Providing and laying on roof pressed clay tile ridge (Mangalore tile) of 20mm thickness of approved pattern on steel frame work complete (steel frame work to be paid separately) 584 12.26 Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 sand : 4 stone aggregate 10mm and down grade) including finishing with cement mortar 1:3 (1 cement : 3 sand) as per standard design : In 75x75mm deep chase 585 12.27 Making khurras 45x45 cm (sunk area) with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1mx1mx400micron, finished with 12mm cement plaster 1:3 (1 cement : 3 sand) and a coat of neat cement rounding the edge and making and finishing the outlet complete so as to receive rain water/ spillage water on roof in a sunk area and completely rain out in a near perfect strain meter motion into rain water pipe. 586 12.28 Providing and fixing M.S. holder bat clamps of approved design to C.I. Or S.C.I. rain water pipes embedded in and including cement concrete blocks 10x10x10cm of Cement Concrete 1:2:4 mix (1 cement : 2 sand : 4 graded stone aggregate 20 mm nominal size) and cost of cutting holes and making good the walls etc. 12.28.1 100 mm diameter 12.28.2 150 mm diameter 587 12.29 Providing and fixing ISI marked sand cast iron rain water pipes. 12.29.1 100 mm dia minimum wall thickness 5mm 12.29.2 150 mm dia minimum wall thickness 5mm 588 12.30 Providing lead caulked joints to sand cast iron rain water pipes and fittings : 12.30.1 100 mm dia. Pipe 12.30.2 150 mm dia. Pipe 589 12.31 Providing, fixing and embedding sand cast iron accessories for rain water pipes in the masonry surrounded with 12 mm thick cement mortar of the same mix, as that of masonry (lead caulking will be paid for separately) : 12.31.1 Sand cast iron bend : 12.31.1.1 100 mm diameter 12.31.1.2 150 mm diameter 12.31.2 Sand cast iron plain shoes : 12.31.2.1 100 mm diameter 12.31.2.2 150 mm diameter 590 12.32 Providing and fixing on wall face Rigid Unplasticised rigid PVC (upvc) Single socketed rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. 12.32.1 75 mm diameter (minimum wall thickness 1.8mm) 12.32.2 110 mm diameter (minimum wall thickness 2.2mm) 591 12.33 Providing and fixing on wall face Unplasticised - UPVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. 12.33.1 Coupler 12.33.1.1 75 mm (minimum wall thickness 1.8mm) 12.33.1.2 110 mm (minimum wall thickness 2.2mm) 12.33.2 Single push fit Coupler : 12.33.2.1 75 mm (minimum wall thickness 1.8mm) 12.33.2.2 110 mm (minimum wall thickness 2.2mm) 12.33.3 Single tee with door 12.33.3.1 75x75x75 mm (minimum wall thickness 1.8mm) 12.33.3.2 110x110x110 mm (minimum wall thickness 2.2mm) 12.33.4 Single tee without door 12.33.4.1 75x75x75 mm (minimum wall thickness 1.8mm) 12.33.4.2 110x110x110 mm (minimum wall thickness 2.2mm) 12.33.5 Bend 87.5° 12.33.5.1 75 mm bend (minimum wall thickness 1.8mm) 12.33.5.2 110 mm bend (minimum wall thickness 2.2mm) 12.33.6 Shoe (Plain) 12.33.6.1 75 mm Shoe (minimum wall thickness 1.8mm) 12.33.6.2 110 mm Shoe (minimum wall thickness 2.2mm) 592 12.34 Providing and fixing unplasticised - PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 12.34.1 75 mm (minimum wall thickness 1.8mm) 12.34.2 110 mm (minimum wall thickness 2.2mm) 593 12.35 Providing and fixing to the inlet mouth of rain water pipe fixing cast iron grating 15 cm diameter and weighing not less than 440 grams. 594 12.36 Providing and fixing to the inlet mouth of rain water pipe PTMT (an Engineering Thermoplastic) grating square (Slit) 150 mm square with a height of 8 mm and weighing not less than 100 gms. 595 12.37 Providing and fixing 100 mm/110 mm diameter and 60 cm long rain water spout in cement mortar 1:4 (1 cement : 4 sand) 12.37.1 Stone ware spout 12.37.2 Upvc spout (Pipe dia.110 mm) 596 12.38 Providing and fixing of self-supported mechanically seamed roofing system, made of high quality steel, having 340 MPA yield strength, pre coated galvalume sheet as per ASTM A 792 M of base metal thickness from 0.8 mm to 1.6mm (tolerance ± 0.02mm). High grade steel sheet should have 55% aluminum and 45% zinc coating by hot-dip process of minimum 25 micron The rate includes supplying, fixing, loading unloading, hire charges of all plants machineries, anchors, fasteners, washers, bolts, epoxy, paint and all wastage etc. complete. Accessories and fixtures like hangers/clamps for installation of lighting /fixtures /utility/ duct as per requirement and ventilators, skylight can also be provided at crown/ridge by making cuts into the panels which is to be paid separately. This item shall be executed only by the agency which has all required manufacturing machineries and necessary expertise. 12.38.1 Base metal thickness 0.8mm up to span 15 meter 12.38.2 Base metal thickness 0.9mm , up to span 18 meter 12.38.3 Base metal thickness 1.0 mm, up to span 21 meter 12.38.4 Base metal thickness 1.1 mm, up to span 23 meter 12.38.5 Base metal thickness 1.2mm, up to span 25meter 12.38.6 Base metal thickness 1.3 mm, up to span 27 meter 12.38.7 Base metal thickness 1.4mm, up to span 29meter 12.38.8 Base metal thickness 1.5 mm, up to span 31 meter 12.38.9 Base metal thickness 1.6 mm, up to span 33 meter 12.38.10 Providing and fixing galvalume 1.0 mm thick clamps/hangers of size 75X140mm with saddle of 50mm dia, riveted at one side and nut and bolt at other side, to self-supported roofing system by mechanical seaming to suspend light fixture/cable stay/false ceiling/duct etc., at their location which should be planned earlier by engineer-in-charge. Clamps shall be fixed during seaming of panels. 12.38.11 Providing and fixing advanced type hurricane turbo ventilator to self- supporting roof having neck dia 600mm made of aluminum having 24 nos vertical vanes made of aluminum sheet. Ventilator should be fixed on 1 to 2mm thick G.I. ring which shall be fixed on 2mm thick polycarbonate sheet. Polycarbonate sheet shall have foam tap or rubber gasket under and over it and fixed by 1 to 2 mm thick aluminum angle 25X25mm with self- tapping screw to panels. All joints shall be sealed by silicon. Rates i/c of all material, labour fittings screw, rings, foam tap, aluminum angles etc. complete. Deduction shall not be made for cutting area of self-supported roof. 12.38.12 Providing and fixing of 2mm thick polycarbonate sheet to self-supported roofing system. The sheet shall have tensile strength and elongation as per ASTM D 638, refractive index as per ASTM D 592, light transmission as per ASTM D 1003 and specific gravity as per STM D 792. Polycarbonate sheet shall have foam tap or rubber gasket under and over it and fixed by 1 to 2 mm thick aluminum angle 25X25mm with self- tapping screw to panels. All joints shall be sealed by silicon. Rates include of all material, labour, fittings, screw, foam tap, aluminum angles etc. complete. Deduction shall not be made for cutting area of self-supported roof. 597 12.39 Supply, fabrication and erection of three-dimensional space frame steel structure consisting of support node, primary space frame members, space notes nodes, bolts, sleeves (nut), purlin stool, purlin etc. to support roof sheet in plain or curved shape. (Approximate zinc coating thickness 77 Microns) and shall not be less than 400 g/sqm (Approximate zinc coating thickness 56 microns). Bolts, sleeves and cones shall be electro-galvanized to ASTM B 633 Type 2, SC3. Shop drawings along with structural design analysis shall be provided by the manufacturer for approval of the engineer in charge. Rate shall include cost of design, all material, all lifts, labour, transport, storage, machines, tools and plants, wastages, erection and installation at site all necessary scaffolding etc. necessary to provide finished product but excluding cost of erection/construction of support shaft and roof sheet. 598 12.40 Providing and fixing roofing consist of 0.8 mm thick galvanized steel deck sheet confirming to IS 277:1992 used as permanent shuttering over which MS wire mesh 3mm laid at 100x100 mm grid including edge trim covered with concrete. This metal deck will be supported on structural steel beam with shear studs. (Structural steel like Beam, column, joists etc. & concrete of different grade as per design will be paid separately). 599 12.41 Providing and fixing in position roof tile under lay using 12mm thick(minimum) Moisture/fire Resistance heavy duty fibre cement board(High Pressure Steam Cured) Type A,Category 4 conforming to IS 14862:2000, fixed on Steel frame work of 610mmx610mm or 610mmx1220mm grid by counter sunk stainless screw @ 300mm C/C all complete as per the drawings. Tiles etc may be laid on the board substrate by sealing the joints properly with filler material or sealant to ensure no leakage through joints. All complete as per drawings, specification and as per direction of Engineer-in-Charge.Note - MS Section structure and roof tile like Shingles/Mangalorian Tiles etc cost will be paid seprately. 600 12.42 Providing and fixing thermal insulation of ceiling (under deck insulation) with Resin Bonded Fibre glass wool conforming to IS: 8183 density 24kg/m3, 50mm thick, wrapped in 200 G Virgin Polythene bags fixed to ceiling with metallic cleats (50x50x3 mm) @ 60 cm and wire mesh of 12.5mm x 24 gauge wire mesh, for top most ceiling of building. 601 12.43 Providing and fixing thermal insulation with Resin Bonded Fibre glass wool conforming to IS : 8183, density 16kg/m3, 50mm thick, wrapped in 200G Virgin Polythene bags placed over existing false ceiling and held in position by criss-crossing GI wire. 602 12.44 Thermal Insulation of roofing with Expanded polystyrene fixed with suitable adhesive to the false ceiling as per the directions of the Engineer-in-charge : 603 12.44.1 With Type N - Normal 50 mm thick 604 12.44.2 With Type SE - Self Extinguishing type 50 mm thick. 605 12.45 Providing and laying thermal insulation of roofing with 40 mm thick impervious sprayed, closed cell free Rigid Polyurethane foam over deck insulation conforming to IS - 12432 Pt. III (density of foam being 40-45 kg/cum), over a coat of polyurethane primer applied @ 6-8 sqm per litre, laying 400 G polythene sheet over PUF spray and providing a wearing course of 40 mm thick cement screed 1: 2 : 4 (1 cement : 2 sand : 4 stone aggregate 20 mm nominal size) in chequered rough finish, in panels of 2.5 mx2.5 m and embedding with 24 G wire netting and sealing the joints with polymerized mastic, all complete as per direction of Engineer-in-Charge. 606 12.46 Providing and fixing thermal insulation with Resin Bonded Fibre glass wool conforming to IS: 8183 having density 24 kg/m3, 50 mm thick, wrapped in 200G Virgin Polythene Bags fixed to wall with screw, rawl plug and washers and held in position by criss crossing GI wire etc. complete as per directions of Engineer-in- Charge. 607 12.47 Providing and fixing thermal insulation of ceiling (under deck insulation) with Resin Bonded Rockwool conforming to IS: 8183, density 48 kg/ m3, 50 mm thick, wrapped in 200 G Virgin Polythene bags fixed to ceiling with metallic cleats (50x50x3 mm) @ 60 cm and wire mesh of 12.5mm x 24 gauge wire mesh, for top most ceiling of building. 608 12.48 Providing and fixing thermal insulation with Resin bonded rock wool conforming to IS: 8183, density 48 kg/m3, 50 mm thick, wrapped in 200 G virgin Polythene bags placed over existing false ceiling and held in position by criss- crossing GI wire. 609 12.49 Providing and fixing thermal insulation with Resin Bonded rock wool conforming to IS: 8183, having density 48 kg/m3. 50 mm thick, wrapped in 200 G Virgin Polythene Bags fixed to wall with screw, rawl plug and washers and held and in position by criss cossing GI wire etc.complete as per directions of Engineer-in-Charge. 610 12.50 Supply and application of 48kg/m3 density & 50 mm thick with a tolerance of -2 + 6mm of Rockwool RB slabs unfaced (Binder<3.5%); conforming to IS: 8183/ASTM C 612 latest edition with amendments. Non- combustible when tested as per BS 476 Part 4 or A1 when tested as per EN: 13501. Two random samples from each supplied batch will be test for shot content at the site. The melting point of the wool shall be more than 1000°C and wool shall be bio-soluble in accordance with EU directive 127/2008 or similar. All Above mentioned standard are as per latest edition with amendments. 611 12.51 Supply & Application of Rockwool RB slab 48kg density, 50mm thick wrapped in 200G vergine polythene bags for partition, ceiling (Under Deck insulation) conforming to IS: 8183 with tolerance of -2 +6mm of rock wool RB slabs unfaced (Binder <3.5%) conforming to IS: 8183/ASTM C 612 latest edition with amendments. Non-combustible when tested as per BS 476 Part 4 or Al when tested per EN 13501. . Two random samples from each supplied batch will be test for shot content at the site. The melting point of the wool shall be more than 1000°C and wool shall be bio-soluble in accordance with EU directive 127/2008 or similar. All Above mentioned standard are as per latest edition with amendments. 612 12.52 Supply & Application of Rockwool RB 2 slab 64kg /m3, 50mm thick, with GI wire netting 24 SWG; fixing for NRC Value 1.00 for Acoustics, thermal & fire purpose conforming to and IS: 8133, IS: 8183 with tolerance of -2 + 6mm of RB slabs unfaced (Binder < 3.5%); conforming to IS: 8183/ASTM C 612 latest edition with amendments. Two random samples from each supplied batch will be tested for shot content at the site. The melting point of the wool shall be more than 1000°C and wool shall be bio-soluble in accordance with EU directive 127/2008 or similar. All Above mentioned standard are as per latest edition with amendments. 613 12.53 Supply & Application of Rockwool building roll (1.1mx10m) 48kg density, 50mm thick with FSK (foil scrim Kraft) aluminium foil facing for HVAC duct & building underdeck purpose conforming to IS: 8183, IS: 8183 and IS:8183 a tolerance of -2 +6 mm of Rockwool RB slabs unfaced (Binder < 3.5%) ; conforming to IS: 8183; /ASTM C 612 latest edition with amendments. Non-combustible when tested as per BS: 476 Part 4 or Al when tested as per EN: 13501. Two random samples from each supplied batch will be test for shot content at the site. The melting point of the wool shall be more than 1000°C and it shall be bio-soluble in accordance with EU directive 127/2008 or similar. All Above mentioned standard are as per latest edition with amendments. 614 12.54 Supply & Application of Rockwool Building Roll (1.1mX10m) 48kg density, 50mm thick with ALG (Alu & glass) mixture of Aluminium & glass facing for building underdeck application below metal sheet also conforming IS: 8183, IS: 8183 and IS: 8183 a tolerance of -2+6mm of rockwool RB slabs unfaced (Binder < 3.5%); conforming to IS: 8183/ASTM C 612 latest edition with amendments. Non-combustible when tested as per BS 476 Part 4 or Al when tested as per EN 13501. The maximum service temperature shall be 700°C. Shot content should be less than 2% for 500 microns & less than 10% for 250 microns when tested as per standard IS: 3144. Two random samples from each supplied batch will be test for shot content at the site. The melting point of the wool shall be more than 1000°C and wool shall be bio-soluble in accordance with EU directive 127/2008 or similar. All Above mentioned standard are as per latest edition with amendments. 615 12.55 Providing and fixing of minimum 12mm thick, 5 layered bubble Reflective thermal insulation made of 12 microns aluminum foil with minimum 97% Reflectivity on both outer sides, under both aluminum foil 4mm thick FR bubble insulation with Low Emissivity - 0.032 (ASTM1371), Fire Class A (ASTM E84) All five layers of insulation shall be stick with each other by registered manufacturer using hot process without using any kind of adhesive. Insulation shall be supplied in 1.10m wide roll width with 50mm wide factory-made cuts at both sides to joint another roll by using general stapler in case of new shed and adhesive in case of existing or self-supported roof. 12.55.1 Fixing of insulation on new work by laying horizontally on the purlins and perpendicular to the direction of purlins and fixing by using self- tapping screws at equal distance. Place and align the second roll of insulation parallel to the first roll and overlaps the adjacent rolls. After Insulation is fixed over the purlins the metal sheet is placed over insulation and drilled with self-tapping screws with purlins etc. complete, including all material and scaffolding. 12.55.2 Installation of insulation in Old Sheds where the sheets have been already fixed over the purlins so insulation shall be fixed under the purlins covering the roof bottom. Insulation roll to be unfolded at the bottom of the purlin horizontally and parallel to the roof and fixed by using the self- tapping screw with a washer at equal distance etc. Complete, including all material and scaffolding. 12.55.3 Insulation of Self-Supported Roof shall be applied under the roofing by using stud welding to the self- supported roof at a distance not be more than 300 mm in both directions. At each stud insulation roll shall be pushed against the studs so that it gets punctured and then non-returning washer has to be applied at the stud etc. complete, including all material and scaffolding. 616 12.56 Providing and fixing 50 mm thick extruded polystyrene rigid insulation board (XPS) of required size over- deck on ceiling surface, complying with ASTM C 578 - type VI, having thermal conductivity of 0.0289 W/mK as per ASTM C 518, compressive strength of > 350 kPa listed as per ASTM C 1621, density of 34-36 kg/m³ as per ASTM D 1622, water absorption < 1% by volume as per ASTM C 272, oxygen index of minimum 24 as per ASTM D 2863 and Fire retardant property as per DIN 4102, with preferred stone or pre-cast tiles shall be laid over the XPS board with suitable grouting including providing pre-fabricated EPDM drain outlets (Cement Screed casting shall be done at the junction of roof and parapet walls), all as per the directions of Engineer-in-charge. 617 12.57 Providing and fixing 50 mm thick extruded polystyrene rigid insulation board of required size underdeck on ceiling surface, complying with ISO 4898:2008 & ASTM C 578-08b - type VI, having thermal conductivity of 0.0289 W/m K as per ASTM C 578 Fire retardant property as per DIN 4102, Part 1 of class B2 and as per ASTM E84 class A, fixed with suitable water based adhesive and fastener, complete in all respect as per the directions of Engineer-in-Charge. 618 12.58 Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, jointing tapes, finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturers specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with: 12.58.1 10mm thick plaster of Paris (gypsum anhydrous) sheet 10mm thick pop board 12.58.1.1 Flat surfaces 12.58.1.2 Curved surfaces 12.58.1.3 Sunk or raised mouldings 12.58.1.4 Extra for providing in the plaster of Paris (Gypsum anhydrous) ceiling above 5 metre height from floor level. 12.58.2 12.5 mm thick tapered edge gypsum board 12.58.2.1 Plain board conforming to IS: 2095- Part I : 2011 (Board with BIS certification marks). 12.58.2.2 Fire resistant Glass Reinforced Gypsum (GRG) board conforming to IS: 2095- (Part 3) : 1996 (Board with BIS certification marks) 12.58.2.3 Gypsum moisture resistant board. 12.58.2.4 Fully Perforated Gypsum Plaster Board having approx. 15 % perforated area with perforation size and pattern as approved by the Engineer-in-charge and as per manufacturers specification, with all 4 side tapered and backed by acoustical tissue with NRC value not less than 0.60. 12.58.3 8 mm thick Calcium Silicate Board made with Calcareous and Siliceous materials reinforced with cellulose fiber manufactured through autoclaving process. 619 12.59 Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of mainT runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanized butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre- painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. 12.59.1 GI Metal Ceiling Lay in plain Tegular edge Global white color tiles of size 595x595 mm, and 0.5 mm thick with 8 mm drop; made of G I sheet having galvanizing of 100 gms/sqm (both sides inclusive) and electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending. 12.59.2 GI Metal Ceiling Lay in perforated Tegular edge global white color tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/sqm (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fiber acoustical fleece. 12.59.3 12.5 mm thick square edge PVC Laminated Gypsum Tile of size 595x595 mm, made of Gypsum plasterboard, manufactured from natural gypsum as per IS 2095 part I and laminated with white 0.16mm thick fire retardant PVC film on the face side and 12micron metalized polyester on the back side with all edges sealed with the face side PVC film which goes around and wraps the edges and is bonded to the edges and the back side metalized polyester film so as to make the tile a ompletely sealed unit. 12.59.4 12.5 mm thick fully Perforated Gypsum Board tile made from plasterboard having glass fibre conforming to IS: 2095 part I, of size 595x595 mm, having perforation of 9.7x9.7 mm at 19.4 mm c/c with center borders of 48 mm and the side borders of 30 mm, backed with non woven tissue on the back side, having an NRC (Noise Reduction Coefficient) of 0.79, with 50 mm resin bonded glass wool backing. 12.59.5 Glass fiber Acoustical Suspended Ceiling System with 16 mm thick tegular edge or micro look edge tiles of size 595x595mm.The tiles should have Humidity Resistance (RH) of 99%, NRC 0.5, Light Reflectance ≥83%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Colour White, Fire Performance UK Class 0 / Class 1 (BS 476 pt - 6 and7) in module size of 600 x 600 x 16mm with Bio Block coating on the face of the tile, suitable for Green Building application, with Recycled content of 38 - 41%. The Tile and Grid system used together should carry a 15 year warranty. 12.59.6 8mm thick non-asbestos multipurpose termite, fire & moisture resistance cement bonded particle board as per IS: 14276, white primedcolour tiles of size 595X595 mm. 12.59.7 6mm thick non-asbestos multipurpose termite, fire & moisture resistance cement bonded particle board as per IS: 14276, white primed colour tiles of size 595X595 mm. 620 12.60 Providing and fixing GI Clip in Metal Ceiling System of 600x600 mm module which includes providing and fixing ‘C’ wall angle of size 20x30x20mm made of 0.5mm thick pre painted steel along the perimeter of the room with help of nylon sleeves and wooden screws at 300mm center to centre, suspending the main C carrier and in direction perpendicular to it at 600mm centers with help of suspension brackets. Wherever the main C carrier and spring T have to join, C carrier and spring T connectors have to be used. All sections to be galvanized @ 120 gms/sqm (both side inclusive) Fixing with clip in/swing down tiles into spring T with 12.60.1 GI Metal Ceiling Clip in /swing down plain Beveled edge global white color tiles of size 600x600 and 0.5mm thick with 25mm height, made of G I sheet having galvanizing of 100 gms/sqm (both sides inclusive) and electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending. 12.60.2 GI Metal Ceiling Clip in /swing down plain Beveled edge global white color tiles of size 600x600 and 0.5mm thick with 25mm height, made of G I sheet having galvanizing of 100 gms/sqm (both sides inclusive) and 20% perforation area with 1.8mm dia holes and having NRC of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation. 621 12.61 Providing & Fixing of Unperforated Antibacterial Metal Tile Ceiling System comprising of Tile of 600mm wide and 600mm long manufactured out of 0.7mm thick aluminium alloy 3105 with beveled edge of 4.15mm width and height of 32mm. The Tile will be manufactured on advanced equipment that includes several levelling stages in the manufacturing process by approved certified manufacturers. The Tile shall be clipped into clip in rail of 0.5mm thick G.I. in form of a grid system using a cross connector. The clip in rail shall be supported from slab by means of rigid Suspension of 4mm G.I.Road, Hold on Clamp with Clip. (Rate include all materials and labour). 622 12.62 Providing and fixing board ceiling of approved quality with necessary nails etc. complete (frame work to be paid separately): 12.62.1 12mm thick insulating board 12.62.1.1 Natural colour insulating board 12.62.1.2 White face insulating board 12.62.1.3 Flame retardant face insulating board 12.62.2 Flat pressed 3 layer medium density particle board or graded particle board (Grade I) IS: 3087 12 mm thick marked in ceiling with necessary nails etc. complete 12.62.3 6 mm thick plain Multipurpose Cement board ( High Pressure steam cured ) as per IS : 14862, with suitable screws for fibre cement board in ceiling etc. complete 12.62.4 6mm thick High Pressure Steam Cured non asbestos, reinforced with cellulose fibres,Moistur& fire Resistance heavy duty fibre cement board, Type A,Category 4 conforming to IS 14862:2000.(for wet areas) 12.62.5 4 mm thick High Pressure Steam Cured non asbestos, pre-painted, self- embossed, designer cement boardType B, Category 3 conforming to IS 14862:2000 . of approved texture,design patterns 623 12.63 Extra for Circular cutting and wastages in ceiling with: board only (frame work) Natural colour insulating 12 mm thick board paid separately. 624 12.64 Extra for providing and fixing ceiling to curved surfaces in narrow widths 625 12.65 Providing and fixing false ceiling with 12 mm thick plain/ semi perforated or with design ceiling tiles of BWP type phenol formaldehyde synthetic resin bonded pressed particle board conforming to IS:3087, finished with a coat of aluminium primer on both sides and edges including two coats of synthetic enamel paint of approved quality on exposed face, fixed to a grid made out of anodised aluminium (with 15 micron anodic coating) The frame work shall be suspended from ceiling by level adjusting hangers of 6 mm dia M.S rod fixed to roof slab by means of ceiling cleats and dash fastener. The suspenders shall be placed 600 x 1200 mm centre to centre including fixing to the frame with C.P brass screws and applying a priming coat of zinc chromate yellow primer (aluminium frame work shall be paid separately). 626 12.66 Providing and Fixing colour coated profile sheet of minimum 1015 mm effective cover width and nominal 28.5 mm deep ribs with subtle square fluting in the five pan at nominal 203 mm centre-to-centre. The end rib shall be designed for anti-capillary action, to avoid any seepage of water through the lateral overlap. The sheet shall have brand marking of the manufacturer giving product details on the back of the sheet at every 1 meter c/c for confirming genuinity of the material. The sheet shall be fixed using self- drilling /self-tapping screws of size (5.5x 55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces excluding the cost of purlins, rafters and trusses and including cutting to size and shape 627 12.67 Extra for providing 3 mm thick translucent white acrylic plastic sheets of approved quality in false ceiling instead of 12 mm thick plain or design particle board ceiling tiles. 628 12.68 Providing and fixing expanded polystyrene (thermacol) false ceiling (frame work to be paid separately) : 12.68.1 With Type N - Normal 50 mm thick 12.68.2 With Type SE - Self Extinguishing type 50 mm thick 629 12.69 Providing and fixing false ceiling with fabric fixing with nail etc. (frame work and beading to be paid separately). 12.69.1 costing upto 70/- per metre, 12.69.2 Rs 70- 150 per meter 12.69.3 Upto 200 per meter 630 12.70 Providing and fixing perforated Aluminium panel ceiling of white/ natural satin colour supplied by approved manufacturers consisting of panel of standard size with bevel edge, panel length up to 6 m, coil Coated on a Continuous Paint Line suitable for Interior application, double baked and roll formed from enamelled corrosion resistance aluminium alloy AA 5050 (Al. Mg) for higher strength and good roll forming characteristics. Panel carrier shall be suspended by means of G.I. threaded rod having 6 mm diameter at a distance of 1.5 mtr. Actual distance of threaded rod/carrier might vary and to be calculated based on the actual drawing and site condition. The Measurements shall be wall to wall without any deductions for lights, diffusers, columns etc. 12.70.1 With panels of size 300mm wide X30mm deep X 0.7mm thick and panel carrier of size 40.5mm wide X 62mm deep X 0.9mm thick 12.70.2 With panels of size 150mm wide X 15.5 mm deep X 0.5mm thick and panel carrier of size 32mm wide X 39mm deep X 0.95mm thick 12.70.3 With panels of size 84mm wideX16mm deep X 0.5mm thick and panel carrier of size 62mm wide X 29mm deep X 0.95mm thick 631 12.71 Providing and fixing un-perforated Aluminium Panel ceiling Supplied by approved manufacturers of standard white/ natural satin shade consisting of panel 30 mm/80mm/130mm/180mm wide X 15 mm deep X 0.5mm /0.6mm thick respectively, with square edges having panel length up to 6 mtr, Coil Coated on a Continuous Paint Line, Double baked and roll formed from enamelled corrosion resistance Aluminium alloy AA 5050 (Al.Mg) for higher strength and good roll forming characteristics. The Carrier shall be suspended by means of G.I. suspension rod 4mm diameter, and a Galvanised suspension spring clip at a distance of 1.7mtrs centre to centre. Actual distance of threaded rod/carrier might vary and to be calculated based on the actual drawing and site condition. The Measurements shall be wall to wall without any deductions for lights, diffusers, columns etc. 632 12.72 Providing and fixing U Baffle Aluminium panel ceiling of different colors and finish supplied by approved manufacturers, consisting of panel size 50 mm width X 100 mm deep using 0.6 mm thick, panel length upto 4 mtr, Coil Coated on a Continuous Paint Line, Double baked and roll formed from enamelled corrosion resistance Aluminium alloy AA 3005 (Al. Mg) for higher strength and good roll forming characteristics. Actual distance of threaded rod/carrier might vary and to be calculated based on the actual drawing and site condition. The measurements shall be wall to wall without any deductions for lights, diffuses, columns etc. As an option, ceiling area above U Baffle can be painted by the contractor in black colour or any other colour as per the architect for better aesthetics before fixing this system. 12.72.1 Standard White / Natural Satin Shade 12.72.2 Wooden Finish 633 12.73 Supply & Fixing of perforated G.I false ceiling tile or plank using torsion spring fixing system supplied by approved manufacturer comprising of tile of 600 mm wide and 600 mm long manufactured out of 0.5 mm thick or plank of 600mm wide and 1200 mm long manufactured out of 0.6mm thick galvanised steel perforated with 2 mm dia. at a distance of 5mm centre to centre. Non-woven felt made of glass- reinforced fibre glued over the perforation at the back side of panels to provide noise reduction co efficient up to 0.7 NRc. “Tee” sections, 3.6m long, with factory punched flanges to receive torsion spring assembly. Main Tee on centre spacing to match panel length. Cross runners 24 mm deep, inverted “Tee” sections designed to interlock in to web of main tee section on designated spacing. Cross tee length to match panel length. Cross tees are spaced at a spacing of 600 mm on centre maximum. The measurements shall be wall to wall without any deductions for lights, diffusers, columns etc. 12.73.1 Tile of 600 mm wide ,600 mm long and 0.5 mm thick 12.73.2 Plank of 600mm wide ,1200 mm long and 0.6mm thick 634 12.74 Providing and fixing of composite perforated Gypsum board with Glass wool Fiber panel of Size 595x595x25 mm with 10mm square Perforation tiles false ceiling in true horizontal level suspended on interlocking metal grid of hot dipped galvanized steel section (Galvanized @ 120 gms/sqm both sides inclusive) consisting of main “ “T” runners to be suspended from ceiling using GI slotted plates of size 27x37x25x1.6 mm fixed to ceiling with 12.50 mm dia and 40 mm long dash fasteners, 4 mm GI adjustable rods with galvanized butterfly level clips of size 85x30x0.80 mm spaced @ 1200mm centre to centre along with main T, bottom exposed width of 24mm of all T-sections shall be pre- painted with polyester paint all complete at all heights as per specifications and drawings and as directed by Engineer-in-Charge. 635 12.75 Providing and fixing of Composite perforated MDF board with Glass wool Fiber panel of Size 595x595x18 mm 10mm Square Perforation tiles (Square /Tegular Edge) false ceiling in true horizontal level suspended on interlocking metal grid of hot dipped galvanized steel section (Galvanized @ 120 gms/sqm both sides inclusive) consisting of main “T” runners to be suspended from ceiling using GI slotted plates of size 27x37x25x1.6 mm fixed to ceiling with 12.50 mm dia and 40 mm long dash fasteners, 4 mm GI adjustable rods with galvanized butterfly level clips of size 85x30x0.80 mm spaced @ 1200mm centre to centre along with main T, bottom exposed width of 24mm of all T-sections shall be pre- painted with polyester paint all complete at all heights as per specifications and drawings and as directed by Engineer-in-Charge. 636 12.76 Providing and fixing of Perforated Gypsum board with Acoustical Glass Fiber Tissue faced panel of Size 595x595x12.5mm, Square 10mm Perforation tiles (Square Edge) false ceiling panels in true horizontal level suspended on interlocking metal grid of hot dipped galvanized steel section (Galvanized @ 120 gms/sqm both sides inclusive) consisting of main “T” runners to be suspended from ceiling using GI slotted plates of size 27x37x25x1.6 mm fixed to ceiling with 12.50 mm dia and 40 mm long dash fasteners, 4 mm GI adjustable rods with galvanized butterfly level clips of size 85x30x0.80 mm spaced @ 1200mm centre to centre along with main T, bottom exposed width of 24mm of all T-sections shall be pre- painted with polyester paint all complete at all heights as per specifications and drawings and as directed by Engineer-in-Charge. 637 12.77 Providing and fixing mineral fibre false ceiling tiles at all heights of size 595X595mm of approved texture, design and pattern. The tiles should have Humidity Resistance (RH) of 99%, Light Reflectance≥ 85%, Thermal Conductivity k = 0.052 -0.057 w/m K, Fire Performance as per (BS 476 pt - 6 &7)in true horizontal level suspended on interlocking TGrid of hot dipped all round galvanized iron section of 0.33 mm thick (galvanized @120 gsm) comprising of main T runners of 15x32 mm of length 3000 mm, cross T of size 15x32mm of length 1200 mm and secondary intermediate cross T of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling usinggalvanized mild steel item (galvanised@80gsm) 50 mm long 8mm outer diameter M-6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and L-shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘T’. The system should rest on periphery walls /partitions with the help of GI perimeter wall angle of size24x24X3000 mm made of 0.40 mm thick sheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall S.S. screws. The exposed bottom portion of all T-sections used in false ceiling support system shall be prepainted with polyester baked paint, for all heights. The work shall be carried out as per specifications, drawings and as per directions of the engineer-incharge. With 16 mm thick beveled tegular mineral fibre false ceiling tile (NRC 0.55 to 0.6) 638 12.78 Providing and fixing false ceiling at all heights with 15 mm thick integral densified micro look edged non- cementitious light weight calcium silicate false ceiling tile reinforced with fibre and natural filler false ceiling tiles of Size 595x595 mm of approved texture, design The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in-Charge.80 grams per sqm) i.e. 50 mm long, 12 mm outer diameter M-6 dash fasteners with the help of Z cleat of 27x37x27x2 mm, 6 mm dia fully threaded hanger rod upto 1000 mm length and L-shape level adjuster of size 85x25x25x2 mm. Galvanised iron perimeter wall angle of size 22x19x0.40 mm of length 3000 mm to be fixed on periphery wall / partition with the help of plastic rawl plugs at 450 mm centre to centre and 40mm long dry wall S.S screws. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in-Charge. 639 12.79 Providing and fixing false ceiling at all heights with 15 mm thick integral densified mirolook edge with BIO SAFE coating as per ISO 7251:2005, ISO 20743:2007 and ISO 21527-1:2008, making the tiles resistant to bacterial growth in case of any external bacterial contact made onto the surface of tiles, non-cementitious light weight calcium silicate false ceiling tile reinforced with fibre and natural filler false ceiling tiles of Size 595x595 mm with the help of Z cleat of 27x37x27x2 mm, 6 mm dia fully threaded hanger rod upto 1000 mm length and L-shape level adjuster of size 85x25x25x2 mm. Galvanised iron perimeter wall angle of size 22x19x0.40 mm of length 3000 mm to be fixed on periphery wall / partition with the help of plastic rawl plugs at 450 mm centre to centre and 40mm long dry wall S.S screws. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in-Charge. 640 12.80 Providing and fixing in position wall panelling at all heights with 15 mm thick fully perforated square/butt edge light weight calcium silicate panels/ tiles., non-cementitious, reinforced with fibre and natural filler, having NRC (Noise Reduction Coefficient) of 0.10-0.20 for plain and designer 0.15-0.40 for pinhole texture and NRC 0.45-0.65 for fully perforated tiles as per IS 8225:1987, sound attenuation STA-32db. of 0.75 (minimum) as per IS 8225:1987, Light Reflectance of 85% (minimum), non-combustible as per BS:476 (part-4), 50-52% recycled content including fly ash, The joints between the panels are to be duly jointed and finished using recommended jointing calcium silicate based compound and fibre joint tape roll 50mm wide (90 metre) roll and two coats of primer suitable for panelling as per manufacturers specification as per direction of engineer-in-charge all complete. With 15 mm thick fully perforated square/butt edge light weight calcium silicate panels/ tiles. 641 12.81 Providing & fixing false ceiling at all heights with GRG (Glass Fibre Reinforced Gypsum) false ceiling tiles of Size 595x595 mm of approved texture, design and patterns having moisture content less than 2%, humidity resistance of 99%, NRC0.50 to 0.75 as per IS 8225:1987, Galvanised iron perimeter wall angle of size 24x24x0.40 mm of length 3000 mm to be fixed on periphery wall / partition with the help of plastic rawl plugs at 450 mm center to center and 40 mm long dry wall wood screws. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in- Charge. 12.81.1 With semi perforated 12mm thick micro tegular edged GRG false ceiling tiles. 12.81.2 With fully perforated 10mm thick square edged GRG false ceiling tiles for sound proof and acoustic. 642 12.82 Providing and Fixing 15 mm thick densified tegular edged eco friendly light weight calcium silicate false ceiling tiles of approved texture of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped 387alvanized steel sections (387alvanized387 @ 120 grams per sqm including both side) consisting of main ‘T’ runner suitably spaced at joints to get required length and of size 24x38 mm made from 0.33 mm thick (minimum) sheet, spaced 1200 mm centre to centre, and cros‘T’, bottom exposed with 24 mm of all Tsections shall be pre-painted with polyster baked paint, for all heights, as per specifications, drawings and as directed by Engineer- in-Charge.Note :- Only calcium silicate false ceiling area will be measured from wall to wall. No deduction shall be made for exposed frames/ opening (cut outs) having area less than 0.30 sqm.The calcium silicate ceiling tile shall have NRC value of 0.50 (Minimum), light reflection > 85%, non- combustible as per B.S. 476 part IV, 100% humidity resistance and also having thermal conductivity 643 12.83 Providing and fixing upvc plank, Plank size (340 X 2700 ) mm as per approved shade, the panel shall be laser catted end of plank fixing j-trim fixed and corner edge of ceiling fixed u pvc clip same colour and providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 125 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts,other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular,j trim end clip includes in this item any other item not be paid sepratly complete in all respect as per the directions of Engineer-in-Charge. . 644 12.84 Providing & Fixing PVC ceiling system profile panel with click system interlock panel size 4000mmx340mmx1mm resistance to weather perfect finish in wood grain & solid colour maintenance free Resistance to weather truly anti bacterial. with edge profile J-trim on periphery & center profile T-trim in panel joint Complete System to be fixed on G.I. framework of ceiling section at 450 mm distance with enter section suspended by roof by G.I. angle hanger in proper line & level etc complete . PRODUCT SPECIFICATIONS: Meets or exceeds the standard specification of (ASTM D-4477) and its referenced documents. observed. (Tested at 50 LBS) Tensile strength, MPa: >37.0 Tensile modulus, MPa: >2000 Surface distortion: None at 120F Squareness: <1/8” of square Length: Within ¼” of specification Lock control: Complies Color Change: <2 grayscales (16 hrs under 1200W/m2 UV radiation at 50 degrees) 645 12.85 Design built, supply and erection of Tensile (fabric) structure system including designing and fabrication in M.S. steel tubular structure as per Indian standard section as per approved design and shape including base plate, dash fastener, clits etc. Cutting, patterning, plotting and wielding of fabric with the help of tensile structure software. Fabric should be wielded by high frequency PVC wielding in proper line with PVC cader to be fixed on end of the fabric and to be stretched & fixed on M.S. design structure with the help of. M.S. Flat bar with self-taping screw. M.S. structure to be painted with one coat of epoxy primer with MRF PUpaint of approved colour in desired shape. With 1050 GSM tensile fabric 12.85.1 With precontraint tensile membrane 1050 GSM (20 years Warranty) 12.85.2 With precontraint tensile membrane 1050 GSM (15 Years warranty) 646 13.1 12 mm cement plaster of mix : 13.1.1 1:4 (1 cement : 4 sand) 13.1.2 1:6 (1 cement : 6 sand) 647 13.2 15 mm cement plaster on the rough side of single or half brick wall of mix 13.2.1 1:4 (1 cement : 4 sand) 13.2.2 1:6 (1 cement : 6 sand) 648 13.3 20 mm cement plaster of mix : 13.3.1 1:4 (1 cement : 4 sand) 13.3.2 1:6 (1 cement : 6 sand) 649 13.4 12 mm cement plaster finished with a floating coat of neat cement of mix : 13.4.1 1:3 (1 cement : 3 sand) 13.4.2 1:4 (1 cement : 4 sand) 650 13.5 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix 13.5.1 1:3 (1 cement : 3 sand) 13.5.2 1:4 (1 cement : 4 sand) 651 13.6 18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement : 5 sand) finished with a top layer 6mm thick cement plaster 1:4 (1 cement : 4 sand). 652 13.7 18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement : 5 sand) and a top layer 6mm thick cement plaster 1:3 (1 cement : 3 sand) finished rough with sponge. 653 13.8 6 mm cement plaster of mix : 1:3 (1 cement : 3 sand) 654 13.9 6 mm cement plaster 1:3 (1 cement : 3 sand) finished with a floating coat of neat cement and thick coat of Lime wash on top of walls when dry for bearing of R.C.C. slabs and beams. 655 13.10 Neat cement punning 656 13.11 Rough cast plaster upto 10m height above ground level with a mixture of sand and gravel or crushed stone from 6mm to 10mm nominal size dashed over and including the fresh plaster in two layers, under layer 12mm cement plaster 1:4 (1 cement: 4 sand) and top layer 10mm cement plaster 1:3 (1 cement: 3 sand) mixed with 10% finely grounded hydrated lime by volume of cement. Finished with ordinary cement. 657 13.12 Pebble dash plaster upto 10m height above ground level with a mixture of washed pebble or crushed stone 6mm to 12.5mm nominal size dashed over and including fresh plaster in two layers under layer 12mm cement plaster 1:4 (1 cement: 4 sand) and top layer 10mm cement plaster with cement mortar 1:3 (1 cement: 3 sand) mixed with 10% finely grounded hydrated lime by volume of cement. 658 13.13 Providing sand faced plaster upto 10meter hight above ground level concrete or brick masonry surfaces in two coats, base coat of 13 mm thick in cement mortar 1:4 (1 cement: 4 sand), clearing the surface by combing it and finishing coat of 8 mm. thick in cement mortar 1:3 (1 cement: 3 sand) and taking out surface grains by mechanical arrangement or applying second coat by mechanical means including cost of all material, labour, and T and P including all lead, lift and scaffolding etc. complete. 659 13.14 Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers. 660 13.15 Extra for plastering 13.15.1 Exterior walls of height more than 10 m from ground for every additional height of 3 m or part thereof 13.15.2 Interior walls of height more than 6 m from floor level for every additional height of 3 m or part thereof 661 13.16 Extra for plastering on circular work not exceeding 6 m in radius: 13.16.1 In one coat 13.16.2 In two coats 662 13.17 Extra for plastering done on moulding cornices or architraves including neat finish to line and level: 13.17.1 In one coat 13.17.2 In two coats 663 13.18 Extra for plastering Spherical, Groined ceiling, Flewing soffits. 13.18.1 Spherical ceiling 13.18.2 Groined ceiling 13.18.3 Flewing soffits 664 13.19 Washed stone grit plaster on exterior walls of height upto 10 M. above ground level in two layers, under layer 12mm cement plaster 1:4 (1 cement : 4 sand ) furrowing the under layer with scratching tool, applying cement slurry on the under layer @ 2 Kg of cement per square metre, top layer 15mm cement plaster 1:1/2:2 (1 cement : 1/2 sand : 2 stone chipping 10mm nominal size) in panels with groove all around as per approved pattern including scrubbing and washing, the top layer with brushes and water to expose the stone chippings,complete as per specification and direction of Engineer- in- charge (Payment for providing grooves shall be made separately). 665 13.20 Forming groove of uniform size 20 or 15 mm wide and 15 mm deep in the top layer of washed stone grit plaster as per approved pattern using wooden battens, nailed to the under layer including removal of wooden battens, repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge : 666 13.21 Extra for washed grit plaster on exterior/interior walls of height more than 10m from ground/floor level for every additional height of 3 m or part thereof. 667 13.22 Extra for washed stone grit plaster on circular work not exceeding 6m in radius (in two coats). 668 13.23 Forming groove of uniform size from 12x12mm and upto 25x15mm in the top layer of washed stone grit plastered surface as per approved pattern, including providing and fixing aluminum channels of appropriate size and thickness (not less than 2 mm), nailed to the under layer with rust proof screws and nails and finishing the groove complete as per specifications and direction of the Engineer-in-Charge. 669 13.24 Extra for using white cement in place of ordinary cement in the top layer of the item of washed stone grit plaster. 670 13.25 Providing and applying 12 mm thick (average) premixed formulated one coat gypsum lightweight plaster having additives and light weight aggregates as vermiculite/ perlite respectively conforming to IS: 2547 (Part -1 and II) 1976, applied on hacked/ uneven background such as bare brick/ block/ RCC work on walls and ceiling at all floors and locations,excluding in wall which may come in contact with dampness finished in smooth line and level etc. complete. 671 13.26 Extra for addition of synthetic Polyester triangular fibre of length 6mm, effective diameter 10-40 microns and specific gravity of 1.34 to 1.40 in cement plaster/mortar by using 125gms. Of synthetic Polyester triangular fibre for 50 Kgs. cement used in cement mortar as per directions of Engineer-in-Charge. 672 13.27 Providing and fixing mesh in vertical and horizontal junction of RCC and brick/AAC work including scaffolding and all lead and lift etc. complete 673 13.27.1 G.I. chicken mesh as per ISI specification and in the required width with 50mm long Bombay nails before plastering upt 10 meter height. 13.27.2 Providing and fixing fibre mesh of 145 GSM weight in required width with cement mortar before plastering upto 10m height. 674 13.28 12 mm thick plain cement mortar bands in cement mortar 1:4 (1 cement : 4 sand) : 13.28.1 Flush Band 13.28.2 Sunk Band 13.28.3 Raised Band 13.28.4 Moulded Band 675 13.29 18 mm thick plain cement mortar band in cement mortar 1:4 (1 cement : 4 sand): 13. 29.1 Flush Band 13. 29.2 Sunk Band 13. 29.3 Raised Band 13. 29.4 Moulded Band 676 13.30 18 mm thick moulded cement mortar band in two coats under layer 12mm thick with cement mortar 1:5 (1 cement : 5 sand) top layer 6mm thick with cement mortar 1:4(1 cement : 4 sand). 677 13.31 Pointing on brick work or brick flooring with cement mortar 1:3 (1 cement : 3 sand) : 13.31.1 Flush / Ruled/ Struck or weathered pointing. 13.31.2 Raised and cut pointing 13.31.3 Sunk pointing 678 13.32 Pointing on stone work with cement mortar 1:3 (1 cement: 3 sand). 13.32.1 Flush/ Ruled pointing 13.32.2 Raised and cut pointing 679 13.33 Raised and cut pointing on stone work in white cement mortar 1:3 (1 white cement : 3 marble dust) 680 13.34 Pointing on stone slab ceiling with cement mortar 1:2 (1 cement : 2 sand): Flush/ Ruled pointing 681 13.35 Extra for pointing on walls on the outside/inside at height more than 10 metre from ground/floor level for every additional height of 3 m or part there of. 682 13.36 Providing and fixing broken glass in cement mortar 1.3 including cost of mortar, over compound walls. 683 13.37 Providing and fixing writing board green writing with chalk (regular modified polyster coated steel surface). of sizes. 13.37.1 size 1200mmx1800mm 13.37.2 size 1200mmx2400mm 13.37.3 size 1200mmx3000mm 684 13.38 Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete 685 13.39 Providing and applying plaster of paris punning of 10 mm average thickness over plastered surface to prepare the surface even and smooth complete. 686 13.40 Extra for lining out plaster to imitate stone or concrete blocks walling. 687 13.41 Providing and applying white cement based putty of average thickness 1 mm, of approved brand over the plastered wall surface to prepare the surface even and smooth i/c all cost of material, labour and scaffold etc in all position complete. Note : Putty shall be applied only on the internal walls, for application on the exterior walls prior permission of APD/Chief Engineer will be required. 688 13.42 Providing and applying special putty in two coats based materials varnish, Belgium chalk, turpentine oil, white paint, safeda including sand papering for making the surface smooth for applying any or vinyl paints including all cost of material and labouretc complete. 689 13.43 White washing with lime to give an even shade: New work (three or more coats) 690 13.44 Colour washing such as green, blue or buff to give an even shade: New work (two or more coats) with a base coat of white washing with lime. 691 13.45 Distempering with 1st quality acrylic distemper (ready mixed) having VOC (Volatile Organic Compound) content less than 50 grams/ltr of approved manufacturer, of required shade and colour complete, as per manufacturers specification. Two or more coat on new work. 692 13.46 Wall painting by any mechanical or manual means with plastic emulsion paint of approved brand and manufacture to give an even shade: Two or more coats on new work 693 13.47 Distempering by any mechanical or manual means with 1st quality acrylic distemper, having VOC (Volatile Organic Compound) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. 13.47.1 One coat. 13.47.2 Two coats. 694 13.48 Wall painting by any mechanical or manual means with acrylic emulsion paint, having VOC (Volatile Organic Compound) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. 13.48.1 One coat. 13.48.2 Two coats. 695 13.49 Wall painting by any mechanical or manual means with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound) content less than 50 grams/ litre. of approved brand and manufacture, including applying additional coats wherever required to achieve even shade. 696 13.50 Finishing walls by any mechanical or manual means with water proofing cement paint of required shade: New work (Two or more coats applied @ 3.84 kg/10 sqm). 697 13.51 Finishing walls by only mechanical or manual means with textured exterior paint of required shade: New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm. 698 13.52 Finishing walls by any mechanical or manual means with Acrylic Smooth exterior paint (Economy Exterior) of required shade including all scaffolding. New work (Two or more coat applied @1.67ltr/10sqm over and including one coat undiluted exterior waterproofing coating @ 2.39 litre/10 sqm with crack bridging ability of upto 0.5mm on horizontal surfaces with an elongation of 150% and water proofing of upto 3 bars on vertical surface 699 13.53 Finishing walls by any mechanical or manual means with Premium Acrylic Smooth exterior paint (Premium exterior) of required shade including all scaffolding. New work (Two or more coat applied @1.67ltr/10sqm over and including one coat undiluted exterior waterproofing coating @ 2.39 litre/10 sqm with crack bridging ability of upto 0.5mm on horizontal surfaces with an elongation of 150% and water proofing of upto 3 bars on vertical surface) 700 13.54 Finishing walls by any mechanical or manual means with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : 13.54.1 Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/ 10 sqm of approved brand or manufacture 13.54.2 Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/ 10 sqm of approved brand or manufacture. 13.54.3 Two or more coats applied on walls @ 1.25 ltr/10 sqm. Over and including one coat of Special primer applied @ 0.75 ltr / 10 sqm. 701 13.55 Painting with silicon and acrylic emulsion based water thinnable sealer of approved brand and manufacture on wet or patchy portion of plastered surfaces: 13.55.1 One coat 13.55.2 Two coats 702 13.56 Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturers specifications including appropriate priming coat, preparation of surface, etc. complete. 13.56.1 On steel work 13.56.2 On concrete work 703 13.57 Painting on G.S. sheet with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: New work (two or more coats) including a coat of approved steel primer but excluding a coat of mordant solution. 704 13.58 Applying a coat of mordant solution on G.S. sheet : 13.58.1 With a solution of 38 gms of copper acetate in a litre of soft water 13.58.2 With a solution made of 13 gms of hydrochloric acid in a solution of 13 gms each of copper chloride, copper nitrate and ammonium chloride dissolved in a litre of soft water. 705 13.59 Painting (two or more coats) on rain water, soil, waste and vent pipes and fittings with black anticorrosive bitumastic paint approved brand and manufacture over and including a priming of ready mixed zinc chromate yellow primer on new work : 13.59.1 75 mm diameter pipes 13.59.2 100 mm diameter pipes 13.59.3 150 mm diameter pipes 706 13.60 Painting (two or more coats) on rain water, soil, waste and vent pipes and fittings with synthetic enamel paint of approved brand and manufacture and required colour over a priming coat of approved steel primer on new work. 13.60.1 75 mm diameter pipes 13.60.2 100 mm diameter pipes 13.60.3 150 mm diameter pipes 707 13.61 Painting with oil type wood preservative of approved brand and manufacture: New work (two or more coats) 708 13.62 Providing and applying two coats of fire retardant paint on cleaned wood/ply surface @ 3.5 sqm per litre per coat including preparation of base surface as per recommendations of manufacturer to make the surface fire retardant. 709 13.63 Coal tarring two coats on new work using 0.16 and 0.12 litre coal tar per sqm in the first coat and second coat respectively. 710 13.64 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade: Two or more coats on new work. 711 13.65 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture. 712 13.66 Painting with synthetic enamel paint, having VOC (Volatile Organic Compound) content less than 150 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. 13.66.1 One coat. 13.66.2 Two coats. 713 13.67 Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. 13.67.1 With ready mixed pink or grey primer on wood work (hard and soft wood) having VOC content less than 50 grams/ litre. 13.67.2 With ready mixed red oxide zinc chromatic on steel/ iron works having VOC content less than 250 grams/litre. 13.67.3 With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre. 714 13.68 Painting with aluminium paint of approved brand and manufacture to give an even shade. Two or more coats on new work. 715 13.69 Painting with acid proof paint of approved brand and manufacture of required colour to give an even shade: Two or more coats on new work. 716 13.70 Painting with black anti-corrosive bitumastic paint of approved brand and manufacture to give an even shade: Two or more coats on new work. 717 13.71 Floor painting with floor enamel paint of approved brand and manufacture of required colour to give an even shade: Two or more coats on new work 718 13.72 Varnishing with varnish of approved brand and manufacture: 13.72.1 Two or more coats of glue sizing with copal varnish over an under coat of flatting varnish. 13.72.2 Two or more coats glue sizing with spar varnish or an under coat of flatting varnish. 719 13.73 French spirit polishing: Two or more coats on new works including a coat of wood filler. 720 13.74 Polishing on wood work with ready mixed wax polish of approved brand and manufacture: New work. 721 13.75 Lacqer polishing on door windows by preparing the surface applying putty base course. Prepare the surface smooth by sand papering and then applying lacqer polish with air compressor. Two or more coats on new works including a coat of wood filler. 722 13.76 Mealamine polishing on door windows by preparing the surface applying putty base course. Prepare the surface smooth by sand papering and then applying mealamine polish with air compressor. Two or more coats on new works including a coat of wood filler. 723 13.77 Floor polishing on masonry or concrete floors with wax polish of approved brand and manufacture. 724 13.78 Lettering with black Japan paint of approved brand and manufacture. 725 13.79 Providing and applying flakes textured homogeneous wall finishing system consisting of a two component system of dry flakes (9.5kgs per/pack) made of a special grade of heat treated China clay with rigid homopolymer coated with fade resistant pigments and a 100% acrylic polymer Bonding agent (5kgs/pack) applied thickness of the coating being between 0.8-1.2mm, to be applied in single coat, on a cured, smooth level plaster surface without keying, as per the shades/ combinations approved, as per manufacturers directions for usage, to be applied by approved applicator of manufacturer, as per direction/ supervision of the engineers-in-charge inclusive of one coat of primer on the base at all heights etc all complete. 726 13.80 Providing and applying Granules homogeneous wall finishing system consisting of a two component system of dry granules (25 kgs/pack) made of 92% silica particles coated with fade resistant pigments and a 100% acrylic Polymer Bonding agent (5 kgs/pack) with the applied thickness of coating as required to be applied in single coat, on a cured. Smooth level plaster surface without keying as per the shades/combinations approved. As per the manufacturers directions for usage, to be applied by approved applicator of manufacturer, as per the directions/supervision of engineers in charge, all complete inclusive of primer on the base. 13.80.1 0.8-1.2mm thickness 13.80.2 2.0-2.5mm thickness 727 13.81 Providing and Applying Roto Wall finishing system being a dispersion of inorganic fillers, calcite, pure silica, quartz and broad spectrum fungicides stabilized by an acrylic co-polymer, to be applied by means of customized trowels (one for incorporating material on base and spreading and other for finishing) in single coat with a coating thickness of 2.0-2-2.5mm on a cured smooth level plaster without keying, by the approved applicator of manufacturer, of the approved shade as per directions for usage all inclusive including primer coat on the base. 728 13.82 Providing and plastering over AAC masonary wall with polymer modified cement based readymix factory controlled mortar with self curing, eco- friendly, wet premix in a mechanical mixer in thickness as specified below, and covering area of 2.04 kg per sqm/mm thickness. The Bulk density of ready mix plaster may vary from 1300 to 1600 Kg/cum, Water powder ratio (as per manufacture’s direction) may vary from 18-22 % by weight or as specified by the manufacturer and compressive strength may vary from 8-9 Mpa. 13.82.1 6 mm thick plaster for internal walls 13.82.2 8 mm thick plaster for external walls exposed to weather. 729 13.83 Providing and fixing including Designing and UV printing on aluminium composite material (ACM) sheet in different sizes with 720DPI (Dot per inch) 13.83.1 ACP sheet 2mm thick 13.83.2 ACP sheet 3mm thick 13.83.3 ACP sheet 4mm thick 730 13.84 Providing and fixing including designing and UV printing on pvc foam sheet of different size with 720 DPI (Dot per inch) 13.84.1 PVC foam sheet 3.0 mm thick 13.84.2 PVC foam sheet 5.0 mm thick 13.84.3 PVC foam sheet 8.0 mm thick 731 13.85 Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives.New work (Two or more coats applied @ 1.43 litre/ 10 sqm. Over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm. 732 13.86 Providing and fixing 50 mm thick extruded polystyrene rigid insulation board (XPS) of required size over outer wall surface, complying with ASTM C 578 - type VI, having thermal conductivity of 0.0289 W/mK as per ASTM and Fire retardant property as per DIN 4102, Part 1. XPS insulation of thickness 50mm shall be placed over brushed, algae free and levelled external wall by connecting the ship-laps joints and fixed by the washer and Self-Tapping Screw of suitable length at each corner and at distance 75mm from the edge and bitumen shall be applied over the joints and G.I. Expanded Mesh (Barfi Jali) shall be fixed over XPS board by a Self- Tapping Screw of suitable length at the centre of the board and 15mm PCC shall be applied over the board (paint of suitable choice can be used), all as per the directions of Engineer-in-Charge. 733 13.87 Providing and fixing 50 mm thick extruded polystyrene rigid insulation board of required size between cavity wall, complying with ISO 4898:2008 & ASTM C 578-08b - type VI, having thermal conductivity of 0.0289 W/m K as per ASTM C 578 (measured as per IS 3346), compressive strength of > 350 kPa listed as per ASTM D 1621, density of 34-36 kg/cum as per ASTM D 1622, water absorption < 1% by volume as per ASTM D 2842, oxygen index of 24.1 to 28.1 listed as per ASTM D 2863, cell size 0.4 mm of dia (max) as per ASTM D 3576. Fire retardant property as per DIN 4102, Part 1 of class B2 and as per ASTM E84 class A, fixed with suitable water based adhesive and fastener, complete in all respect as per the directions of Engineer-in-Charge. 734 13.88 Painting with oil type wood preservative of approved brand and manufacture: Old work (one or more coats) 735 13.89 Scrapping/sand papering of existing surface with the help of mechanized sanding machine (having mechanical vaccum machine with bag for dust collection to make surface even and smooth) as per direction of Engineer-in- Charge. 736 13.90 Providing and applying 1 coat of Triple booster primer-resist dampness, efflorescence, alkali & at the same time improve top coat coverage by 15-20% @1.0 lt/ 10 sqm, which confirms certfication of IS 109/1968. It can be applied by Brush/ Spray Machine and the work shall be carried out as per secification& the direction of the Engineer-in-Charge. 737 13.91 Finishing walls with water based anti- germ paint of with VOC < 50 g/l, that kills disease causing germs, teflon based washability and Anti fungal properties in two or more coats @ 1.08 ltr / 10 sqm over priming coat of interior primer applied @ 1.08 ltr / 10 sqm of required shade including removing of all dust complete as per direction of Engineer- in-Charge and submission of challans of materials on enquiry. 738 13.92 Providing and applying in two coats of 250 micron thick each layer of epoxy coating on prepared surface (cost includes preparing the plastered surface smooth ready to receive epoxy coating) for operation theater walls in desired colour as per direction of Engineer-in-Charge. 739 14.1 Repairs to plaster of thickness 12mm to 20mm in patches of area 2.5 sq. metres and under including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete including disposal of rubbish to the dumping ground within 50metres lead : With cement mortar 1:4 (1 cement : 4 sand). 740 14.2 Fixing chowkhats in existing opening including embedding chowkhats in floors or walls cutting masonry for holdfasts, embedding hold fasts in cement concrete blocks of size 15 x 10 x 10 cm with cement concrete 1:3:6 (1 cement : 3 sand : 6 graded stone aggregate 20 mm nominal size), painting two coats of approved wood preservative to sides of chowkhats and making good the damages to walls and floors as required complete including disposal of rubbish to the dumping ground within 50 meters lead : 14.2.1 Door chowkhats 14.2.2 Window chowkhats 14.2.3 Clerestory window chowkhats 741 14.3 Fixing chowkhat in existing opening in brick / RCC wall with dash fasteners/ chemical fastener of appropriate size (3nos on each vertical member of door chowkhat and 2 nos. on each vertical member of window chowkhats) including cost of dash fasteners/ chemical fastener. 742 14.4 Making the opening in brick masonry including dismantling in floor or walls by cutting masonry and making good the damages to walls, flooring and jambs complete to match existing surface i/c disposal of mulba/ rubbish as directed by Engineer- in-charge. For door/ window/ clerestory window. 743 14.5 Renewing glass panes, with putty and nails wherever necessary including racking out the old putty: 14.5.1 Float glass panes of thickness 4 mm 14.5.2 Float glass panes of thickness 5.5 mm 744 14.6 Renewing glass panes with now wooden fillets wherever necessary: 14.6.1 Float glass panes of thickness 4 mm 14.6.2 Float glass panes of thickness 5.5 mm 745 14.7 Renewing glass panes and refixing existing wooden fillets: 14.7.1 Float glass panes of thickness 4 mm 14.7.2 Float glass panes of thickness 5.5 mm 746 14.8 Supplying and fixing new wooden fillets wherever necessary: 14.8.1 2nd class teak wood fillets 14.8.2 Haldu/Bija/Kail wood fillets. 747 14.9 Renewal of old putty of glass panes (length). 748 14.10 Refixing old glass panes with putty and nails. 749 14.11 Fixing old glass panes with wooden fillets (excluding cost of fillets). 750 14.12 Providing and fixing 16 mm M.S. Fan clamps of standard shape and size in existing R.C.C. slab including cutting chase, anchoring clamp to reinforcement bar, including cleaning, refilling, making good the chase with matching concrete, plastering and painting the exposed portion of the clamps complete. 751 14.13 Replacing sand stone slabs in roofing laid in cement mortar 1:4 (1 cement : 4 sand) including necessary repairs and cement pointing with same mortar complete including disposal of rubbish to dumping ground within 50 metres of lead : 14.13.1 Red/ white sand stone slabs 30 to 50 mm thick. 752 14.14 Renewing wooden battens in roofs, including making good the holes in wall and painting with oil type wood preservative of approved brand and manufacture complete including removal of rubbish to the dumping ground within 50 metres lead : 14.14.1 Sal wood battens. 753 14.15 Renewing wooden beams in roofs including making good the holes in walls and painting with oil type wood preservative of approved brand and manufacture complete including removal of rubbish to the dumping ground within 50 metres lead : 14.15.1 Not exceeding 4.00 metres in length. 14.15.1.1 Sal wood beams 14.15.1.2 Haldu/Bija/Kail wood fillets. 14.15.2 Above 4.00 metres and upto 5.00 metres length. 14.15.2.1 Sal wood beams 14.15.2.2 Haldu/Bija/Kail wood fillets. 754 14.16 Raking out joints in lime or cement mortar and preparing the surface for re-pointing or replastering including disposal of rubbish to the dumping ground within 50 metres lead. 755 14.17 Taking out wind ties from roof including cutting out rusted bolts, nuts etc. and removing materials to any distance within compound and stacking. 756 14.18 Fixing of old wind tie with new fittings including painting two or more coats with anticorrosive bitumastic paint of approved brand and manufacturer over and including priming coat of ready mixed zinc chromate yellow primer of approved brand. 757 14.19 Renewing bottom rail and/or top runner of collapsible gate including making good all damages and applying priming coat of zinc chromate yellow primer of approved brand and manufacturer. 758 14.20 Renewing Wrought iron or M.S. Wheel or roller of steel door or gate and fitting and fixing the same with necessary clamps, nuts and bolts/welding and erection etc. complete. 14.20.1 Wheel 50 mm dia. and below. 14.20.2 Wheel above 50 mm dia. 759 14.21 Providing and fixing 25 mm thick shutters for cupboard etc. : 14.21.1 Panelled or panelled and glazed shutters : 14.21.1.1 Superior class teak wood including nickel plated bright finished M.S. piano hinges with necessary screws. 14.21.1.2 Ist class teak wood including nickel plated bright finished M.S. piano hinges with necessary screws. 14.21.2 Glazed shutters : 14.21.2.1 Superior class teak wood including nickel plated bright finished M.S. piano hinges with necessary screws. 14.21.2.2 Ist class teak wood including nickel plated bright finished M.S. piano hinges with necessary screws. 760 14.22 Providing and fixing plain jaffri door and window shutters including bright or/and black enamelled M.S. butt hinges with necessary screws 35x10mm laths placed 35mm apart (frames to be paid separately) including fixing 50x12mm beading complete with: 14.22.1 Second class teak wood. 14.22.2 Hard wood, finger jointed 761 14.23 Providing and fixing curtain rods of 1.25mm thick brass plates with two brass brackets fixed with brass screws and wooden plugs etc. wherever necessary complete. 14.23.1 20 mm diameter. 14.23.2 25 mm diameter. 762 14.24 Providing and fixing M.S. round or square bars with M.S. flats at required spacing in wooden frames of windows and clerestory windows. 763 14.25 Providing joists (karries) including hoisting fixing in position and applying wood preservative on unexposed surface etc. complete with: 14.25.1 Sal wood. 14.25.2 Haldu/Bija/Kail wood. 764 14.26 White washing with lime old work to give an even shade : 14.26.1 two or more coats 14.26.2 one or more coats 765 14.27 Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. 766 14.28 Distempering with dry distemper of approved brand and manufacture (one or more coats) and of required shade on old work to give an even shade. 767 14.29 Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade: Old work (one or more coats). 768 14.30 Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. 769 14.31 Painting on G.S. sheet with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: Old work (one or more coats). 770 14.32 Painting (one or more coats) on rain water, soil, waste and vent pipes and fittings with black anticorrosive bitumastic paint of approved brand and manufacture on old work : 14.32.1 75 mm diameter pipes 14.32.2 100 mm diameter pipes 14.32.3 150 mm diameter pipes 771 14.33 Painting (one or more coats) on rain water, soil, waste and vent pipes and fittings with aluminium paint of approved brand and manufacture on old work : 14.33.1 75 mm diameter pipes 14.33.2 100 mm diameter pipes 14.33.3 150 mm diameter pipes 772 14.34 Painting (one or more coats) on rain water, soil, waste and vent pipes and fittings with synthetic enamel paint of approved brand and manufacture and required colour on old work : 14.34.1 75 mm diameter pipes 14.34.2 100 mm diameter pipes 14.34.3 150 mm diameter pipes 773 14.35 Painting with oil type wood preservative of approved brand and manufacture: Old work (one or more coats) 774 14.36 Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade: One or more coats on old work. 775 14.37 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: One or more coats on old work. 776 14.38 Painting with aluminium paint of approved brand and manufacture to give an even shade: One or more coats on old work. 777 14.39 Painting with acid proof paint of approved brand and manufacture of required colour to give an even shade: One or more coats on old work. 778 14.40 Painting with black anti-corrosive bitumastic paint of approved brand and manufacture to give an even shade: One or more coats on old work. 779 14.41 French spirit polishing: One or more coats on old work. 780 14.42 Mealamine polishing on wood work by preparing the surface applying putty base course. Prepare the surface smooth by sand papering and then applying Mealamine polish with air compressor. One or more coats on old work. 781 14.43 Lacquer polishing on wood work by preparing the surface applying putty base course. prepare the surface smooth by sand papering and then applying Lacquer polish with air compressor 14.43.1 One or more coats on old work. 782 14.44 Polishing on wood work with readymade wax polish of approved brand and manufacture : 14.44.1 Old work 783 14.45 Re-lettering with black Japan paint of approved brand and manufacture. 784 14.46 Painting (one or more coats) with black Japan paint of approved brand and manufacture to give an even shade. 785 14.47 Providing and fixing C.P. brass chain and rubber plug complete for sink or wash basin : 14.47.1 32 mm dia 14.47.2 40 mm dia 786 14.48 Distempering with 1st quality acrylic washable distemper (ready mixed) of approved manufacturer and of required shade and colour complete. As per manufacturers specification. One or more coats on old work. 787 14.49 Finishing walls with water proofing cement paint of required shade : 14.49.1 Old work (one or more coats applied @ 2.20 kg/10 sqm) over priming coat of primer applied @ 0.80 liters/10 sqm complete including cost of Priming coat. 14.49.2 Old work (one or more coats @ 2.20 kg/10 sqm) complete. 788 14.50 Finishing walls with textured exterior paint of required shade : 14.50.1 Old work (Two or more coats on existing cement paint surface applied @ 3.28 ltr/10 sqm. 14.50.2 Old work (One or more coats) applied @ 1.82 ltr/10 sqm. 789 14.51 Finishing walls with Acrylic Smooth exterior paint of required shade : 14.51.1 Old work (Two or more coat applied @ 1.67 ltr/ 10 sqm) on existing cement paint surface). 14.51.2 Old work (One or more coat applied @ 0.90 ltr/10 sqm). 790 14.52 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade 14.52.1 Old work (Two or more coats applied @ 1.43 ltr/ 10 sqm) over existing cement paint surface. 14.52.2 Old work (one or more coats applied @ 0.83 ltr/10 sqm). 791 14.53 Finishing walls with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : 14.53.1 One or more coats applied on walls @ 0.85 ltr/10 sqm. 14.53.2 Painting wood work with Deluxe Multi Surface Paint of required shade. One or more coat applied @0.70 ltr/10 sqm 14.53.3 Painting Steel work with Deluxe Multi Surface Paint to give an even shade. One or more coat applied @0.70 ltr/10 sqm. 792 14.54 Varnishing with varnish of approved brand and manufacture: 14.54.1 One or more coats with copal varnish. 14.54.2 One or more coats with spar varnish. 793 14.55 Melamine polishing on wood work (one or more coat). Old work 794 14.56 Varnishing with flatting varnish of approved brand and manufacture one or more coats on old work. 795 14.57 Floor painting with floor enamel paint of approved brand and manufacture of required colour to give an even shade. One or more coat on old work. 796 14.58 40 mm thick stone flooring over 20 mm (average)thick base of cement mortar 1:5 (1 cement : 5 sand) including pointing with cement mortar 1:2 (1 cement : 2 sand) with an admixture of pigment to match the shade of stone. Red sand stone / White sand stone) stone to be supplied by the department. 14.58.1 Rough chiseled dressed stone 14.58.2 Fine dressed stone 797 14.59 Coursed rubble masonry (second sort) with hard stone in Cement mortar 1:6 (1 cement : 6 sand) (Stone shall be supplied by the department) 798 14.60 Laying old cement concrete interlocking paver blocks of any design/shape laid in required line, level, curvature, colour and pattern over and including 50mm thick compacted bed of sand, filling the joints with sand etc. all complete as per the direction of Engineer-in-charge. (Old CC paver blocks shall be supplied by the department free of cost). 799 14.61 Laying at or near ground level old kerb stones of all types in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 sand) including making joints with or without grooves (thickness of joints, except at sharp curve, shall not be more than 5mm) including making drainage opening wherever required etc. complete as per direction of Engineer-in- charge. (Length of finished kerb edging shall be measured for payment). (Old kerb stones shall be supplied by the department free of cost). 800 14.62 Colour washing with lime to give an even shade: 14.62.1 (one or more coats) 14.62.2 (two or more coats) 801 14.63 Conducting adequate nos. of scanning to detect the steel reinforcement in existing RCC elements by using ground/ Wall penetrating radar system to avoid the cutting of Main bars during drilling for inserting bolts etc. complete. 802 14.64 Chipping, Removing, Carefully loose plaster and Concrete work by low impact Hammer, Breaker without damaging the structure as Instructed by Engineer-in-Charge. 803 14.70 Rebaring of TMT bars by drilling hole & embedding bars of different diameter using epoxy grouting compound including all tools and tackles complete. 14.70.1 8 mm dia bar 10 mm dia hole 14.70.2 10 mm dia bar 12 mm dia hole 14.70.3 12 mm dia bar 16 mm dia hole 14.70.4 16 mm dia bar 20 mm dia hole 14.70.5 20 mm dia bar 25 mm dia hole 14.70.6 25 mm dia bar 32 mm dia hole 14.70.7 32 mm dia bar 40 mm dia hole 804 14.71 Providing and fixing chromium plated brass butt hinges with necessary chromium plated brass screws etc. complete. 14.71.1 125x70x4 mm (ordinary type) 14.71.2 100x70x4 mm (ordinary type) 14.71.3 75x65x4 mm (heavy type) 14.71.4 75x40x2.5 mm (ordinary type) 14.71.5 50x40x2.5 mm (ordinary type) 805 14.72 Providing and fixing 85x42 mm chromium plated brass pull bolt lock with necessary chromium plated brass screws, nuts, bolts and washers etc. complete. 806 14.73 Repair to plaster of thickness 12mm to 20 mm in patches of area 2.5 sqm and under, including cutting the patch in proper shape, raking out joints and preparing plastering the wall surface with white cement based polymer modified self curing mortar, including disposal of rubbish, all complete as per the direction of Engineer-In-Charge. 807 14.74 Cleaning of terrace/loft water storage tank (inside surface area) upto 2000 litre capacity at all heights with coconut brushes, duster etc., removal of silt, rubbish from the tank and cleaning the tank with fresh water disinfecting with bleaching powder @ 0.5gm per litre capacity of f tank body with the help of stencil and paint and disposing of malba all complete as per direction of Engineer-in- Charge. (The old date already written on tank should be removed with paint remover or black paint and if date is not written with the stencil or old date is not removed deduction will be made @ Rs. 0.10 per litre) (if during cleaning any GI fittings or ball cock is damaged that is to be repaired by contractor at his own cost and nothing extra will be paid on this account) 808 14.75 Cleaning and desilting of gully trap chamber, including removal of rubbish mixed with earth etc. and disposal of same, all as per the direction of Engineer- incharge. 809 14.77 Cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per direction of Engineer-In-Charge. 14.77.1 Bars upto 12 mm diameter 14.77.2 Bars above 12 mm diameter 810 14.78 Drilling suitable holes in reinforced or plain cement concrete with power driven drill machine to a minimum depth of 100mm upto 200mm in RCC beams, lintels, columns and slabs to introduce steel bars for sunshades/balconies including fixing the steel bars in position using epoxy resin anchor grout of approved make but excluding the cost of reinforcement, all complete as per direction of Engineer-In-Charge. 14.78.1 Upto and including 12mm dia 811 14.83 Providing and injecting approved grout in proportion recommended by the manufacturer into cracks/honey-comb area of concrete/masonry by suitable gun/ pump at required pressure including cutting of nipples after curing etc. complete as per directions of Engineer-in-Charge. (The payment shall be made on the basis of actual weight of approved grout injected.) 14.83.1 Stirrer mixed Acrylic Polymer of approved make @ 2% of weight of cement used) modified Cement slurry made with non shrink compound in concrete/RCC work 14.83.2 Stirrer mixed SBR Polymer (of approved make) modified Cement slurry made with Shrinkage Compensating Cement in concrete/RCC work. 14.83.3 Epoxy injection grout in concrete/RCC work of approved make 812 14.85 Cleaning of exposed concrete surface of sticking material including loose and foreign material by sand blasting with coarse sand followed by and including cleaning with oil free air blast as per direction of Engineer in charge. 813 14.88 Providing and fixing hard drawn steel wire fabric of size 75 x25 mm mesh or other suitable size wire mesh to be fixed & firmly anchored to the concrete surface by means of L shaped mild steel shear key welded with existing reinforcement including the cost of materials, labour, tool & plants as approved by Engineer-incharge. 814 15.1 Demolishing lime concrete manually/by mechanical means and disposal of material within 50 metres lead as per direction of Engineer-in-Charge. 815 15.2 Demolishing cement concrete manually/by mechanical means including disposal of material within 50 metres lead as per direction of Engineer-in- Charge. 15.2.1 Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix). 15.2.2 Nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix). 816 15.3 Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in- Charge. 817 15.4 Extra for cutting reinforcement bars manually/ by mechanical means in R.C.C. work (Payment shall be made on the cross sectional area of R.C.C. work) as per direction of Engineer-in- Charge. 818 15.5 Extra for scrapping, cleaning and straightening reinforcement from R.C.C. work. 819 15.6 Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in- Charge. 820 15.6.1 In lime mortar with old mughal bricks. 15.6.2 In lime mortar. 15.6.3 In cement mortar. 821 15.7 Removing mortar from bricks and cleaning bricks including stacking within a lead of 50 m (stacks of cleaned bricks shall be measured) : 15.7.1 From brick work in lime mortar. 15.7.2 From brick work in cement mortar. 822 15.8 Demolishing stone rubble masonry manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in- Charge: 15.8.1 In lime mortar. 15.8.2 In cement mortar. 823 15.9 Dismantling dressed stone work ashlar face stone work, marble work or precast concrete work manually/ by mechanical means including stacking of serviceable and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge: 15.9.1 In lime mortar. 15.9.2 In cement mortar. 824 15.10 Removing mortar from and cleaning stones and concrete articles (net quantity of stacks of cleaned materials will be measured) : 15.10.1 In lime mortar. 15.10.2 In cement mortar. 825 15.11 Dismantling tile/ Kota stone/ Marble / Granite work in floors/walls and roofs laid in cement mortar including stacking material within 50 metres lead. 15.11.1 For thickness of tiles 10 mm to 25 mm. 15.11.2 For thickness of tiles above 25 mm and upto 40 mm. 826 15.12 Dismantling stone slab flooring laid in cement mortar including stacking of serviceable material and disposal of unserviceable material within 50 metres lead. 827 15.13 Taking out existing CC interlocking paver blocks from footpath/ central verge, including removal of rubbish etc., disposal of unserviceable material to the dumping ground for which payment shall be made separately and stacking of serviceable material within 50 metre lead as per direction of Engineer-in-Charge. 828 15.14 Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : 15.14.1 Of area 3 sq. metres and below. 15.14.2 Of area beyond 3 sq. metres. 829 15.15 Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead: 15.15.1 Of area 3 sq. metres and below. 15.15.2 Of area beyond 3 sq. metres. 830 15.16 Dismantling wood work in frames, trusses, purlins and rafters upto 10 metres span and 5 metres height including stacking the material within 50 metres lead: 15.16.1 Of sectional area below 40 square centimetres. 15.16.2 Of sectional area 40 square centimetres and above. 831 15.17 Extra for dismantling trusses, rafters, purlins etc. of wood work for every additional span of one metre or part thereof beyond 10 metres : 15.17.1 Of sectional area below 40 square centimetres. 15.17.2 Of sectional area 40 square centimetres and above. 832 15.18 Extra for dismantling trusses, rafters, purlins etc. of wood work for every additional height of one metre or part thereof beyond 5 metres : 15.18.2 Of sectional area below 40 square centimetres. 15.18.1 Of sectional area 40 square centimetres and above. 833 15.19 Dismantling steel work in single sections including dismembering and stacking within 50 metres lead in: 15.19.1 R.S. Joists 15.19.2 Channels, angles, tees and flats 834 15.20 Dismantling steel work in built up sections with span upto 10 meter and hieght 5 meter in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 50metres lead. 835 15.21 Dismantling steel work manually/ by mechanical means in built up sections with span upto 10 meter and hieght 5 meter without dismembering and stacking within 50 metres lead as per direction of Engineer-in-Charge. 836 15.22 Extra for dismantling trusses, rafters, purlins etc. of steel work for every additional span of one metre or part thereof beyond 10 metres 837 15.23 Extra for dismantling trusses, rafters, purlins etc. of steel work for every additional height of one metre or part thereof beyond 5 metres. 838 15.24 Extra for marking of structural steel work required to be re- erected. 839 15.25 Removal of old Tarfelt i/c disposal as directed by Engineer in charge. 840 15.26 Demolishing brick tile covering in terracing including stacking of serviceable material and disposal of unserviceable material within 50 metres lead. 841 15.27 Dismantling roofing including ridges, hips valleys and gutters etc., and stacking the material within 50 metres lead of: 15.27.1 G.S. Sheet 15.27.2 Asbestos/ Non asbestors sheet 842 15.28 Dismantling stone slab roofing over wooden karries or R.C.C. battens (dismantling karries and battens to be paid for separately) including stacking of serviceable material and disposal of unserviceable material within 50 metres lead. 843 15.29 Dismantling tiled roofing with battens boarding etc. complete including stacking of serviceable material and disposal of unserviceable material within 50 metres lead. 844 15.30 Dismantling wooden ballies in posts and struts including stacking within 50 metres lead. 845 15.31 Dismantling and stacking within 50 metres lead, fencing posts or struts including all earth work and dismantling of concrete etc. in base of : 15.31.1 T’ or ‘L’ iron or pipe 15.31.2 R.C.C. 846 15.32 Cutting ballies or wooden posts of fencing at the point of projection above the concrete or ground and stacking the same within 50 metres lead. 847 15.33 Dismantling barbed wire or flexible wire rope in fencing including making rolls and stacking within 50 metres lead. 848 15.34 Dismantling wooden trellis work excluding frames but including stacking the serviceable material within 50 metres lead. 849 15.35 Dismantling expanded metal or I.R.C. fabrics with necessary battens and beading including stacking the serviceable material within 50 metres lead. 850 15.36 Dismantling wooden boardings in lining of walls and partitions, excluding supporting members but including stacking within 50 metres lead : 15.36.1 Upto 10 mm thick 15.36.2 Thickness above 10 mm upto 25 mm 15.36.3 Thickness above 25 mm upto 40 mm 851 15.37 Dismantling precast concrete or stone slabs in walls, partition walls etc. including stacking within 50 metres lead: 15.37.1 Thickness upto 40 mm 15.37.2 Thickness above 40 mm upto 75 mm 852 15.38 Dismantling cement asbestos or other hard board ceiling or partition walls including stacking of serviceable materials and disposal of unserviceable materials within 50 metres lead. 853 15.39 Dismantling C.I. or asbestos rain water pipe with fittings and clamps including stacking the material within 50 metres lead : 15.39.1 75 to 80 mm dia pipe. 15.39.2 100 mm dia pipe 15.39.3 150 mm dia pipe 854 15.40 Dismantling G.I. pipes (external work) including excavation and refilling trenches after taking out the pipes manually/ by mechanical means including stacking of pipes within 50 metres lead as per direction of Engineer-in-Charge : 15.40.1 15 mm to 40 mm nominal bore 15.40.2 Above 40 mm nominal bore 855 15.41 Dismantling C.I. pipes including excavation and refilling trenches after taking out the pipes manually/ by mechanical means, breaking lead caulked joints, melting of lead and making into blocks including stacking of pipes and lead at site within 50 metre lead as per direction of Engineer-in-Charge: 15.41.1 Upto 150 mm diameter 15.41.2 Above 150 mm dia upto 300 mm dia. 15.41.3 Above 300 mm diameter 856 15.42 Taking out C.I. cover with frame from R.C.C. top slab of manholes of various sizes including demolishing of R.C.C. work manually/ by mechanical means and stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead as per direction of Engineer-in- Charge. 857 15.43 Taking out C.I. cover with frame from R.C.C. top slab of inspection chambers of various sizes including demolishing of R.C.C. work manually/ by mechanical means and stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead as per direction of Engineer-in- Charge. 858 15.44 Dismantling of road gully chamber of various sizes including C.I. grating with frame including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead including refilling the excavated gap. 859 15.45 Dismantling of flushing cistern of all types (C.I./PVC/Vitrious China) including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead. 860 15.46 Dismantling of C.I. sluice valve including stacking of useful materials within a lead of 50 metres 15.46.1 Upto 150 mm diameter 15.46.2 Above 150 mm diameter 861 15.47 Dismantling of spindle fire hydrant including stacking of useful materials within 50 metres lead. 862 15.48 Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. 863 15.49 Dismantling aluminium/ Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable surplus material and stacking of serviceable material with in 50 meters lead as directed by Engineer-in-Charge. 864 15.50 Dismantling of old S.W. pipes including breaking of joints and bed concrete stacking of useful materials near the site within 50 m lead and disposal of unserviceable materials into municipal dumps: 15.50.1 100 mm diameter 15.50.2 150 mm diameter 15.50.3 200 mm diameter 15.50.4 250 mm diameter 15.50.5 300 mm diameter 15.50.6 350 mm diameter 15.50.7 400 mm diameter 15.50.8 440 mm diameter 865 15.51 Dismantling of manhole including R.C.C. top slab, C.I. cover with frame including stacking of useful materials near the site and disposal of unserviceable materials into municipal dumps within 50 m lead : 15.51.1 Rectangular manhole 90x80 cm and 45 cm deep 15.51.2 Rectangular manhole 120x90 cm and 90 cm deep. 15.51.3 Rectangular arch type manhole 140x90cm and 2.45m deep. 15.51.4 Circular manhole 122 cm diameter and 1.68 m deep 866 15.52 Extra for depth of manholes dismantled: 15.52.1 Rectangular manhole 90x80 cm and beyond 45 cm depth. 15.52.2 Rectangular manhole 120x90 cm and beyond 90 cm depth. 15.52.3 Rectangular arch type manhole 140x90 cm and beyond 2.45m deep (upto 4.25 m depth). 15.52.4 Circular manhole 122 cm diameter and beyond 1.68 m deep (upto 2.29 m depth). 867 15.53 Taking out existing kerb stones of all types from footpath/ central verge, including removal of mortar etc., disposal of unserviceable material to the dumping ground and stacking of serviceable material within 50 metre lead as per direction of Engineer-in- Charge. 868 15.54 Demolishing dry brick pitching in floors, drains etc. including stacking of serviceable material and disposal of unserviceable material within 50 metres lead : 869 15.55 Demolishing mud phaska in terracing and disposal of material within 50 metres lead. 870 15.56 Dismantling jack arch roofing and floors including stacking of serviceable material and disposal of unserviceable material within 50 metres lead. 871 15.57 Demolishing R.B. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in- charge. 872 15.58 Dismantling manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in- charge : 15.58.1 Water bound macadam road 15.58.2 Bituminous road 873 15.59 Dismantling steel cylinder R.C. pipes including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means breaking lead caulked joints, melting of lead and making into blocks including stacking of pipes & lead at site within 50 metres lead as per direction of Engineer-in-charge : 15.59.1 Up to 600 mm diameter 15.59.2 Above 600 mm diameter 874 15.60 Dismantling asbestos cement pressure pipes including excavation and refilling trenches after taking out the pipes manually/ by mechanical means and stacking the pipes within 50 metres lead as per direction of Engineer-in-charge 15.60.1 Up to 150 mm diameter 15.60.2 Above 150 mm diameter 875 15.61 Dismantling of R.C.C. spun vent shaft including excavating the cement concrete pit completely, taking out the shaft, refilling the excavated gap, stacking the useful materials near the site and disposal of unserviceable materials within 50 metres lead. 876 15.62 Dismantling of cement concrete platform along with curtain walls and base concrete etc. including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead: 15.62.1 120 x 120 cm (outside to outside) 15.62.2 210 x 120 cm (outside to outside) 877 15.63 Dismantling of flexible pavement (bituminous courses) by mechanical means and disposal of dismantled material up to a lead of 1 kilometre, as per direction of Engineer-in- charge. 878 15.64 Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. 879 17.1 Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100mm sand cast Iron P or S trap, UPVC P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete including cutting and making good the walls and floors wherever required : 17.1.1 White Vitreous china Orissa pattern W.C. pan of size 580x440mm with integral type foot rests. 17.1.2 Stainless Steel AISI-304(18/8) Orissa pattern W.C. pan of size 585x480 mm with flush pipe and integrated type foot rests. 880 17.2 Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete including cutting and making good the walls and floors wherever required : 17.2.1 W.C. pan with ISI marked white solid plastic seat and lid 17.2.2 W.C. pan with ISI marked black solid plastic seat and lid 17.2.3 Providing and fixing AISI-304 (18/8) European type WC instead of white vitreous china pedestal type water closet. 881 17.3 Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern and C.P. flush bend with fittings and C.I.brackets, 40mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete including painting of fittings and brackets, cutting and making good the walls and floors wherever required : 17.3.1 W.C. pan with ISI marked white solid plastic seat and lid. 17.3.2 W.C. pan with ISI marked black solid plastic seat and lid. 882 17.4 Providing and fixing vitreous china dual purpose closet suitable for use as squatting pan or European type water closet (Anglo Indian W.C pan) with seat and lid fixed with C.P. brass hinges and rubber buffers, 10 litre low level flushing cistern with fitting and brackets, 40mm flush bend, 20mm over flow pipe, with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required White vitreous china dual purpose WC pan with white solid plastic seat and lid with 10 liter low level flushing cistern i/c C.P. flush bend. 883 17.5 Providing and fixing white vitreous china extended wall mounting water closet of size 780x370x690 mm of approved shape including providing and fixing white vitreous china cistern with dual flush fitting, of flushing capacity 3 litre/6 litre (adjustable to 4 litre/8 litres), including seat cover, and cistern fittings, nuts, bolts and gasket etc complete. 884 17.6 Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : 17.6.1 One urinal basin with 5 litre white P.V.C. automatic flushing cistern. 17.6.2 Range of two urinal basins with 5 litre white P.V.C. automatic flushing cistern. 17.6.3 Range of three urinal basins with 10 litre white P.V.C. automatic flushing cistern. 17.6.4 Range of four urinal basins with 10 litre white P.V.C. automatic flushing cistern. 885 17.7 Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass including painting of fittings and cutting and making good the walls and floors wherever require 17.7.1 Single half stall urinal with 5 litre P.V.C. automatic flushing cistern. 17.7.2 Range of two half stall urinals with 5 litre P.V.C. automatic flushing cistern. 17.7.3 Range of three half stall urinals with 10 litre P.V.C. automatic flushing cistern. 17.7.4 Range of four half stall urinals with 10 litre P.V.C. automatic flushing cistern. 886 17.8 Providing and fixing one piece construction white vitreous china squatting plate with an integral longitudinal flushing pipe, white P.V.C. automatic flushing cistern, with fittings, standard size G.I. / PVC flush pipe for back and front flush with standard spreader pipes with fittings, G.I clamps and C.P. brass coupling complete including painting of fittings and cutting and making good the walls and floors etc. wherever required : 17.8.1 Single squatting plate with 5 litre P.V.C. automatic flushing cistern. 17.8.2 Range of two squatting plates with 5 litre P.V.C. automatic flushing cistern. 17.8.3 Range of three squatting plates with 10 litre P.V.C. automatic flushing cistern. 17.8.4 Range of four squatting plates with 10 litre P.V.C. automatic flushing cistern. 887 17.9 Providing and fixing white vitreous china water less urinal of size 600x330x315 mm having antibacterial /germs free ceramic surface, fixed with cartridge having debris catcher and hygiene seal. 888 17.10 Providing and fixing white vitreous china battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre and post flushing with water ( 250 ml and 500 ml consumption), having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of Engineer-in-Charge. 889 17.11 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps,32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require : 17.11.1 White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps. 17.11.2 White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap. 17.11.3 White Vitreous China Wash basin size 550x400 mm with a pair of 15 mm C.P. brass pillar taps. 17.11.4 White Vitreous China Flat back wash basin size 550x400 mm with single 15 mm C.P. brass pillar tap. 17.11.5 White Vitreous China Angle back wash basin size 600x480 mm with single 15 mm C.P. brass pillar tap. 17.11.6 White Vitreous China Angle back wash basin size 400x400 mm with single 15 mm C.P. brass pillar tap. 17.11.7 White Vitreous China Flat back wash basin size 450x300 mm with single 15 mm C.P. brass pillar tap. 17.11.8 White Vitreous China Surgeon type wash basin of size 660x460 mm with a pair of 15 mm C.P. brass pillar taps with elbow operated lever ISI marked. 17.11.9 White Vitreous China Surgeon type wash basin of size 660x460 mm with single 15 mm C.P. brass pillar taps with elbow operated levers ISI marked. 17.11.10 Oval shape wash basin over counter /under counter with 15 mm C.P brass pillar tap (Counter to be paid sepratly). 17.11.11 Stainless Steel AISI-304(18/8) Round basin 405x355 mm with single 15 mm C.P. brass pillar tap 17.11.12 Stainless Steel AISI-304(18/8) Wash basin 530x345 mm with single 15 mm C.P. brass pillar tap. 890 17.12 Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings. 891 17.13 Providing and fixing kitchen sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P. brass waste complete, including painting the fittings and brackets, cutting and making good the walls wherever required : White glazed fire clay kitchen sink of size 600x450x250 mm. 892 17.14 Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS 13983 with C.I. brackets and stainless steel plug 40 mm including painting of fittings and brackets, cutting and making good the walls wherever required : 17.14.1 Kitchen sink with drain board 17.14.1.1 510x1040 mm bowl depth 250mm. 17.14.1.2 510x1040 mm bowl depth 225mm. 17.14.1.3 510x1040 mm bowl depth 200mm. 17.14.1.4 510x1040 mm bowl depth 178mm. 17.14.2 Kitchen sink without drain board 17.14.2.1 610x510 mm bowl depth 200 mm. 17.14.2.2 610x460 mm bowl depth 200 mm. 17.14.2.3 470x420 mm bowl depth 178 mm. 893 17.15 Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug 40mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete including painting of fittings and brackets, cutting and making good the wall wherever required : 17.15.1 Size450x300x150mm 17.15.2 Size600x450x200mm 894 17.16 Providing and fixing White glazed fire clay draining board of size 600x450x25mm with C.I. brackets including painting of brackets, cutting and making good the walls wherever required. 895 17.17 Providing and fixing white vitreous china water closet squatting pan (Indian type) 17.17.1 Long pattern W.C. pan of size 580 mm 17.17.2 Orissa pattern W.C. pan of size 580x440 mm 896 17.18 Extra for using coloured W.C. pan instead of white W.C. pan Orissa pattern W.C. pan 580x440 mm 897 17.19 Providing and fixing white vitreous china pedestal type (European type/ wash down type) water closet pan. 898 17.20 Extra for using coloured pedestal type W.C pan (European type) with low level cistern of same colour instead of white vitreous china W.C pan and cistern. 899 17.21 Providing and fixing a pair of white vitreous china foot rests of standard pattern for squatting pan water closet: 17.21.1 250x130x30 mm 17.21.2 250x125x25 mm 900 17.22 Providing and fixing P.V.C. low level flushing cistern with manually controlled device (handle lever) conforming to IS: 7231, with all fittings and fixtures complete. 10 litre capacity 17.22.1 White 17.22.2 coloured 901 17.23 Providing and fixing controlled flush, low level cistern made of vitreous china with all fittings complete.10 litre (full flush capacity) 17.23.1 White 17.23.2 Coloured 902 17.24 Providing and fixing solid plastic seat with lid for pedestal type W.C. pan complete : 17.24.1 White 17.24.2 Black 17.24.3 Coloured (other than black and white) 903 17.25 Providing and fixing G.I. inlet connection for flush pipe connecting with W.C. pan. 904 17.26 Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350mm or 340x410x265mm sizes respectively. 905 17.27 Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350mm. 906 17.28 Providing and fixing white vitreous china squatting plate urinal with integral rim longitudinal flush pipe. 907 17.29 Providing and fixing white vitreous china wash basin including making all connections but excluding the cost of fittings : 17.29.1 Flat back wash basin of size 630x450mm. 17.29.2 Flat back wash basin of size 550x400mm. 17.29.3 Angle back wash basin of size 600x480mm. 17.29.4 Angle back wash basin of size 400x400mm. 17.29.5 Flat back wash basin of size 450x300mm. 17.29.6 Surgeon type wash basin of size 660x460mm. 908 17.30 Providing and fixing kitchen sink including making all connections excluding cost of fittings. White glazed fire clay sink of size 600x450x250mm. 909 17.31 Providing and fixing white vitreous china laboratory sink including making all connections excluding cost of fittings: 17.31.1 Size 450x300x150 mm. 17.31.2 Size 600x450x200 mm. 910 17.32 Providing and fixing soil, waste and vent pipes: 17.32.1 Sand cast iron socket and spigot (S&S) pipe as per IS: 1729 17.32.1.1 75 mm dia with wall thickness of 5 mm 17.32.1.2 100 mm dia with wall thickness of 5 mm 17.32.2 Spun cast iron socket and spigot (S&S) pipe as per IS: 3989 17.32.2.1 75 mm dia with wall thickness of 3.5 mm 17.32.2.2 100 mm dia with wall thickness of 4 mm 17.32.2.3 150mm dia with wall thickness of 5mm 17.32.3 Hubless Centrifugally cast (spun) iron pipe epoxy coated in side & out side including complete coupling assembly (EPDM rubber gasket stainless steel claim and external metallic/ protective shield as per IS:15905) 17.32.3.1 75 mm dia with wall thickness of 3.5 mm 17.32.3.2 100 mm dia with wall thickness of 3.5mm 17.32.3.3 150mm dia with wall thickness of 4 mm 911 17.33 Providing and filling the joints with spun yarn cement slurry and cement mortar 1:2 ( 1 cement : 2 sand) in S.C.I./ C.I. Pipes : 17.33.1 75 mm dia pipe 17.33.2 100 mm dia pipe 912 17.34 Providing and fixing M.S. holder-bat clamps of approved design to Sand Cast iron/cast iron (spun) pipe embedded in and including cement concrete blocks 10x10x10cm of Cement Concrete 1:2:4 mix (1 cement : 2 sand : 4 graded stone aggregate 20mm nominal size) including cost of cutting holes and making good the walls etc. : 17.34.1 For 75 mm dia pipe 17.34.2 For 100 mm dia pipe 17.34.3 For 150 mm dia pipe 913 17.35 Providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete. 17.35.1 150 mm dia 17.35.1.1 Sand cast iron as per IS – 1729 minimum wall thickness 6.5mm 17.35.1.2 Spun cast iron as per IS – 3989 minimum wall thickness 5 mm 17.35.1.3 Hubless cast(spun) iron as per IS- 15905 minimum wall thickness 3.5 mm 17.35.2 100 mm dia 17.35.2.1 Sand cast iron as per IS – 1729 minimum wall thickness 6.5mm 17.35.2.2 Spun cast iron as per IS – 3989 minimum wall thickness 4 mm 17.35.2.3 Hubless cast(spun) iron as per IS- 15905 minimum wall thickness 3 mm 17.35.3 75 mm dia 17.35.3.1 Sand cast iron as per IS – 1729 minimum wall thickness 6.5 mm 17.35.3.2 Spun cast iron as per IS – 3989 minimum wall thickness 3.5 mm 17.35.3.3 Hubless cast(spun) iron as per IS- 15905 minimum wall thickness 3 mm 914 17.36 Providing and fixing plain bend of required degree. 17.36.1 150 mm dia 17.36.1.1 Sand cast iron as per IS – 1729 minimum wall thickness 6.5mm 17.36.1.2 Spun cast iron as per IS – 3989 minimum wall thickness 5 mm 17.36.1.3 Hubless cast(spun) iron as per IS- 15905 minimum wall thickness 3.5 mm 17.36.2 100 mm dia 17.36.2.1 Sand cast iron as per IS – 1729 minimum wall thickness 6.5mm 17.36.2.2 Spun cast iron as per IS – 3989 minimum wall thickness 4 mm 17.36.2.3 Hubless cast(spun) iron as per IS- 15905 minimum wall thickness 3 mm 17.36.3 75 mm dia 17.36.3.1 Sand cast iron as per IS – 1729 minimum wall thickness 6.5mm 17.36.3.2 Spun cast iron as per IS – 3989 minimum wall thickness 3.5 mm 17.36.3.3 Hubless cast(spun) iron as per IS- 15905 minimum wall thickness 3 mm 915 17.37 Providing and fixing heel rest sanitary bend 17.37.1 100 mm dia 17.37.1.1 Sand cast iron as per IS - 1729 17.37.1.2 Spun cast iron as per IS - 3989 17.37.2 75 mm dia 17.37.2.1 Sand cast iron as per IS - 1729 17.37.2.2 Spun cast iron as per IS - 3989 916 17.38 Providing and fixing double equal junction of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete : 17.38.1.1 150X150X150X150 17.38.1.2 Sand cast iron as per IS - 3989 17.38.2 100x100x100x100mm 17.38.2.1 Sand cast iron as per IS - 1729 17.38.2.2 Spun cast iron as per IS - 3989 17.38.3 75x75x75x75mm 17.38.3.1 Sand cast iron as per IS - 1729 17.38.3.2 Spun cast iron as per IS - 3989 917 17.39 Providing and fixing double equal plain junction of required degree. 17.39.1 150X150X150X150 mm 17.39.1.1 Sand cast iron as per IS - 3989 17.39.2 100x100x100x100mm 17.39.2.1 Sand cast iron as per IS – 1729 17.39.2.2 Spun cast iron as per IS – 3989 17.39.2.3 Hubless cast(spun) iron as per IS- 15905 17.39.3 75x75x75x75 mm 17.39.3.1 Sand cast iron as per IS – 1729 17.39.3.2 Spun cast iron as per IS – 3989 17.39.3.3 Hubless cast(spun) iron as per IS- 15905 918 17.40 Providing and fixing single equal junction of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete. 17.40.1 150X150X150 mm 17.40.1.1 Spun cast iron as per IS - 3989 17.40.2 100x100x100 mm 17.40.2.1 Sand cast iron as per IS - 1729 17.40.2.2 Spun cast iron as per IS - 3989 17.40.3 75x75x75 mm 17.40.3.1 Sand cast iron as per IS - 1729 17.40.3.2 Spun cast iron as per IS - 3989 919 17.41 Providing and fixing single equal plain junction of required degree : 17.41.1 150X150X150 mm 17.41.1.1 Spun cast iron as per IS - 3989 17.41.2 100x100x100 mm 17.41.2.1 Sand cast iron as per IS – 1729 17.41.2.2 Spun cast iron as per IS – 3989 17.41.2.3 Hubless cast(spun) iron as per IS- 15905 17.41.3 75x75x75 mm 17.41.3.1 Sand cast iron as per IS – 1729 17.41.3.2 Spun cast iron as per IS – 3989 17.41.3.3 Hubless cast(spun) iron as per IS- 15905 920 17.42 Providing and fixing double unequal junction of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete :100x100x75x75 mm 17.42.1 Sand cast iron as per IS - 1729 17.42.2 Spun cast iron as per IS - 3989 921 17.43 Providing and fixing double unequal plain junction of required degree: 100x100x75x75 mm 17.43.1.1 Sand cast iron as per IS – 1729 17.43.1.2 Spun cast iron as per IS – 3989 17.43.1.3 Hubless cast(spun) iron as per IS- 15905 922 17.44 Providing and fixing single unequal junction of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete : 100x100x75 mm 17.44.1 Sand cast iron as per IS - 1729 17.44.2 Spun cast iron as per IS - 3989 923 17.45 Providing and fixing single unequal plain junction of required degree : 100x100x75 mm 17.45.1 Sand cast iron as per IS – 1729 17.45.2 Spun cast iron as per IS – 3989 17.45.3 Hubless cast(spun) iron as per IS- 15905 924 17.46 Providing and fixing double equal plain invert branch of required degree: 17.46.1 100x100x100x100 mm 17.46.1.1 Sand cast iron as per IS - 1729 17.46.1.2 Sand cast iron as per IS - 3989 17.46.1.3 Hubless cast(spun) iron as per IS- 15905 17.46.2 75x75x75x75 mm 17.46.2.1 Sand cast iron as per IS - 1729 17.46.2.2 Spun cast iron as per IS - 3989 925 17.47 Providing and fixing single equal plain invert branch of required degree: 17.47.1 100x100x100 mm 17.47.1.1 Sand cast iron as per IS - 1729 17.47.1.2 Sand cast iron as per IS - 3989 17.47.1.3 Hubless cast(spun) iron as per IS- 15905 17.47.2 75x75x75 mm 17.47.2.1 Sand cast iron as per IS - 1729 17.47.2.2 Sand cast iron as per IS - 3989 17.47.2.3 Hubless cast(spun) iron as per IS- 15905 926 17.48 Providing and fixing double unequal invert branch of required degree : 100x100x75x75 mm 17.48.1 Sand cast iron as per IS - 1729 17.48.2 Spun cast iron as per IS - 3989 927 17.49 Providing and fixing single unequal plain invert branch of required degree : 100x100x75 mm 17.49.1 Sand cast iron as per IS - 1729 17.49.2 Spun cast iron as per IS - 3989 17.49.3 Hubless cast(spun) iron as per IS- 15905 minimum wall thickness 928 17.50 Providing and fixing sand cast iron S&S off sets as per IS: 1729 17.50.1 76 mm off sets 17.50.1.1 With 75 mm dia pipe 17.50.1.2 With 100 mm dia pipe 17.50.2 114 mm off sets 17.50.2.1 With 75 mm dia pipe 17.50.2.2 With 100 mm dia pipe 17.50.3 152 mm off sets 17.50.3.1 With 75 mm dia pipe 17.50.3.2 With 100 mm dia pipe 929 17.51 Providing and fixing sand cast iron S&S off sets as per IS: 3989. 17.51.1 75 mm off sets 17.51.1.1 With 75 mm dia pipe 17.51.1.2 With 100 mm dia pipe 17.51.1.3 With 150 mm dia pipe 17.51.2 150 mm off sets 17.51.2.1 With 75 mm dia pipe 17.51.2.2 With 100 mm dia pipe 17.51.2.3 With 150 mm dia pipe 930 17.52 Providing and fixing door piece, insertion rubber washer 3mm thick, bolts and nuts complete : 17.52.1 100 mm 17.52.1.1 Sand cast iron as per IS - 1729 17.52.1.2 Spun cast iron as per IS - 3989 17.52.2 75 mm 17.52.2.1 Sand cast iron as per IS - 1729 17.52.2.2 Spun cast iron as per IS - 3989 931 17.53 Providing and fixing terminal guard: 17.53.1 150mm 17.53.1.1 Sand cast iron as per IS - 1729 17.53.1.2 Spun cast iron as per IS - 3989 17.53.1.3 Hubless cast(spun) iron as per IS- 15905 17.53.2 100 mm 17.53.2.1 Sand cast iron as per IS - 1729 17.53.2.2 Spun cast iron as per IS - 3989 17.35.2.3 Hubless cast(spun) iron as per IS-15905 17.53.3 75 mm 17.53.3.1 Sand cast iron as per IS - 1729 17.53.3.2 Spun cast iron as per IS - 3989 17.53.3.3 Hubless cast(spun) iron as per IS- 15905 932 17.54 Providing and fixing collar: 17.54.1 100 mm 17.54.1.1 Sand cast iron S & S as per IS - 1729 17.54.1.2 Sand cast iron S & S as per IS - 3989 17.54.2 75 mm 17.54.2.1 Sand cast iron S & S as per IS - 1729 17.54.2.2 Sand cast iron S & S as per IS- 3989 933 17.55 Providing lead caulked joints to sand cast iron/ centrifugally cast (spun) iron pipes and fittings of diameter: 17.55.1 150mm 17.55.2 100 mm 17.55.3 75 mm 934 17.56 Providing and fixing M.S. stays and clamps for sand cast iron/ centrifugally cast (spun) iron pipes of diameter : 17.56.1 100 mm dia 17.56.2 75 mm dia 935 17.57 Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors : 17.57.1 100 mm inlet and 100 mm outlet 17.57.1.1 Spun cast iron S & S as per IS: 3989. 17.57.1.2 Sand Cast iron S & S as per IS: 1729. 17.57.1.3 Hubless cast(spun) iron as per IS-15905 17.57.2 100 mm inlet and 75 mm outlet 17.57.2.1 Sand cast iron S & S as per IS - 3989 17.57.2.2 Spun Cast iron S & S as per IS- 1729. 17.57.2.3 Hubless cast(spun) iron as per IS- 15905 936 17.58 Providing and fixing unplasticised Rigid PVC soil and waste pipes conforming to IS: 13592 Type B including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. Single socketed pipes for working pressure of 4 kg/sqcm. (minimum wall thickness 3.2mm) 17.58.1 75 mm diameter 17.58.2 110 mm diameter 937 17.59 Providing and fixing unplasticised PVC moulded fittings/ accessories for unplasticised Rigid PVC soil and waste pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. 17.59.1 Coupler 17.59.1.1 75 mm 17.59.1.2 110 mm 17.59.2 Single pushfit Coupler 17.59.2.1 75 mm 17.59.2.2 110 mm 17.59.3 Single tee with door 17.59.3.1 75x75x75 mm 17.59.3.2 110x110x110 mm 17.59.4 Single tee without door 17.59.4.1 75x75x75 mm 17.59.4.2 110x110x110 mm 17.59.5 Bend 87.50 17.59.5.1 75 mm bend 17.59.5.2 110 mm bend 938 17.60 Providing and fixing Unplasticised - PVC pipe clips of approved design to Unplasticised - PVC soil and waste pipes by means of bombay nail of required length including and making good the wall etc. complete. 17.60.1 75 mm 17.60.2 110 mm 939 17.61 Providing and fixing UPVC trap of self cleaning design complete. Including cost of cutting and making good the wall and floors. 100 mm inlet and 75 mm outlet 940 17.62 Providing and fixing M.S. holder bat clamp of approved design to sand cast iron/ cast iron (spun) pipes comprising of M.S. flat brackets made of 50x5mm flat of specified shape, projecting 75mm outside the wall surface and fixed on wall with 4nos, 6mm dia expansion hold fasteners including drilling necessary holes in brick wall/ CC/ RCC surface and the cost of bolts etc. The pipes shall be fixed to the already fixed brackets with the help of 30mm x1.6mm galvanised M.S. flats of specified shape and of total length 420mm and shall be fixed with M.S. nuts, bolts, and washers of size 25x6mm, one bolts on each side of the pipe. 17.62.1 Total bracket length 580mm of approved shape and design (for single, 100mm dia pipe). 17.62.2 Total bracket length 810mm of approved shape and design (for two, 100mm dia pipes). 17.62.3 Total bracket length 1040mm of approved shape and design (for three, 100mm dia pipes). 941 17.63 Cutting chases in brick masonry walls (clay brick/flyash brick/AAC blocks) for following diameter sand cast iron/ centrifugally cast (spun) iron pipes and making good the same with cement concrete 1:3:6 (1 cement : 3 sand :6 graded stone aggregate 12.5 mm nominal size) including necessary plaster and pointing in cement mortar 1:4 (1 cement : 4 sand) : 17.63.1 100 mm dia 17.63.2 75 mm dia 17.63.3 50 mm dia 942 17.64 Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. 17.64.1 Semi rigid pipe 17.64.1.1 32 mm dia 17.64.1.2 40 mm dia 17.64.2 Flexible pipe (only in residential & complaxes) 17.64.2.1 32 mm dia 17.64.2.2 40 mm dia 943 17.65 Providing and fixing 100 mm sand cast Iron grating for gully trap. 944 17.66 Providing and fixing in position 25mm diameter mosquito proof coupling of approved municipal design. 945 17.67 Providing and fixing bevelled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. 946 17.68 Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shape with 6 mm thick hard board backing 17.68.1 Circular shape 450mm dia. 17.68.2 Rectangular shape 453x357mm 17.68.3 Oval shape 450x350mm (outer dimensions) 17.68.4 Rectangular shape 1500x450 mm 947 17.69 Providing and fixing glass shelf with edges round of supported on anodised aluminium angle frame with C.P. brass brackets and guard rail complete fixed with 40 mm long screws, rawl plugs etc., complete. 948 17.70 Providing and fixing toilet paper holder: 17.70.1 C.P. brass 17.70.2 Vitreous china 949 17.71 Providing and fixing CP brass waste coupling of approved quality and make for sink and wash basin. 17.71.1 Waste coupling 31mm of 79mm length and 62mm breadth 17.71.2 Waste coupling 38mm of 83mm length and 77mm breadth 950 17.72 Providing and fixing CP brass bottle trap of approved quality and make for sink and wash basin. 951 17.73 Providing and fixing CP brass towel rail of approved quality and make 17.73.1 600x20mm 17.73.2 450x20mm 952 17.74 Providing and fixing CP brass towel ring of approved quality and make 200mm dia ring 953 17.75 Providing and fixing CP brass soap dish of approved quality and make 954 17.76 Providing and fixing CP brass Urinal spreader of approved quality and make 955 17.77 Providing and fixing C.P. brass soap container 109 mm wide, 125 high and 112 mm distance from wall of standard shape with bracket of the same material with all fittings etc. of approved quality and conforming to IS: specification. 956 17.78 Providing and fixing C.P. brass grating of approved quality and make conforming to IS: specification. 17.78.1 100 mm dia. 957 17.79 Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour. 17.79.1 Waste coupling 31mm dia of 79mm length and 62mm breadth weighing not less than 45gms. 17.79.2 Waste coupling 38mm dia of 83mm length and 77mm breadth, weighing not less than 60gms. 958 17.80 Providing and fixing PTMT Bottle Trap for Wash basin and sink. 17.80.1 Bottle trap 31mm single piece moulded with height of 270mm, effective length of tail pipe 260mm from the centre of the waste coupling 77mm breadth with 25mm minimum water seal, weighing not less than 260gms. 17.80.2 Bottle trap 38mm single piece moulded with height of 270mm, effective length of tail pipe 260mm from the centre of the waste coupling 77mm breadth with 25mm minimum water seal, weighting not less than 263gms. 959 17.81 Providing and fixing PTMT liquid soap container 109mm wide, 125mm high and 112mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour. Weighing not less than 105 gms. 960 17.82 Providing and fixing PTMT towel ring trapezoidal shape 215mm long, 200mm wide with a minimum distances of 37mm from wall face with concealed fittings arrangement of approved quality and colour. Weighing not less than 88 gms. 961 17.83 Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fitting arrangement of approved quality and colour. 17.83.1 450mm long towel rail with total length of 495mm, 78mm wide and effective height of 88mm, weighing not less than 170gms. 17.83.2 600mm long towel rail with total length of 645mm, width 78mm and effective height of 88mm, weighing not less than 190gms. 962 17.84 Providing and fixing PTMT shelf 440 mm long, 124 mm width and 36 mm height of approved quality and colour. Weighing not less than 300 gms. 963 17.85 Providing and fixing PTMT 15 mm Urinal spreader size 95x69x100 mm with 1/2 BSP thread and shapes. Weighing not less than 60 gms. 964 17.86 Providing and fixing PTMT urinal cock of approved quality and colour. 15 mm nominal bore, 80mm long. 42 mm high and 30mm wide with BSP female threads weighing not less than 48 gms. 965 17.87 Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements. Weighing not less than 106 gms. 966 17.88 Painting C.I. cistern with bitumastic or any other anti-corrosive paint inside and white paint over a coat of zinc chromate yellow primer (of approved quality) on the outside surface of the cistern, flush pipe, other fittings, etc. complete for new work. 967 17.89 Re-painting C.I. cistern with bitumastic or any other anti-corrosive paint inside and white paint on the outside surface of the cistern, flush pipe, other fittings, etc. complete including polishing of wooden seat and lid and cleaning of W.C. pan with acid wherever necessary. 968 17.90 Repainting C.I. cistern with synthetic enamel paint of approved colour brand and manufacture on the outside surface of cistern flush pipe, other fittings etc. complete. 969 17.91 Painting sand cast iron/ centrifugally cast (spun) iron soil, waste vent pipes and fittings with two coats of synthetic enamel paint of any colour such as chocolate grey, or buff etc. over a coat of primer (of approved quality) for new work : 17.91.1 75 mm diameter pipe 17.91.2 100 mm diameter pipe 17.91.3 150 mm diameter pipe 970 17.92 Repainting sand cast iron/ centrifugally cast iron (spun) iron, soil, waste, vent pipes and fittings with one coat of synthetic enamel paint of any colour such as chocolate, grey or buff etc : 17.92.1 75 mm diameter pipe 17.92.2 100 mm diameter pipe 17.92.3 150 mm diameter pipe 971 17.93 Repainting bath tub of size 1700x730x430mm with enamel paint. 972 17.94 Providing and laying Ceramic glazed half round pipe drain (having thickness 9 to 10mm) of approved make in colours such as White, Ivory, Grey, or any other colour, laid on 20 mm thick Cement Mortar 1:4 (1 Cement : 4 sand) including pointing the joints with white cement and matching pigment etc., complete. 17.94.1 100 mm dia half round pipe 17.94.2 150 mm dia half round pipe 17.94.3 200mm dia half round pipe 973 17.99 Construction of manually operated fire based incinerator for girls-toilet i/c (i)   Fire and ash collection chamber 0.60x0.60 m, made of calcium silicate bricks, having 12mm dia steel bars grating @10 cm c/c, i/c MS mesh weldedon top including 300 mm x 450 mm MS openable door of half grill and half MS plate (3mm thick ).(ii)     0.40 m X 0.40 m duct made of 1.6 mm thick MS sheet for dropping napkins from the toilet opening.(iv) 150mm dia Class C heavy duty MS pipe conforming to IS 3589/1239 for gas emission with cowel, up to 2.10 meter height above terrace level.(v) Opening in wall having MS flap (1.6mm thick) of size 0.25X 0.25 m, finished with granite.etc complete as per standard drawing no. 5313-B-NB4-9919- R1 dated 21.02.2017 17.99.1 For ground floor buildings. 17.99.2 For Ground floor & Ist floor buildings. 17.99.3 Add extra for every additional floor above Ist floor. 974 17.95 Providing and fixing coupler for PVC pipes & fittings waste/rain water/drainage disposal of superior Indian make (as approved by Engineer incharge) i/c jointing with rubber rings, adhesive, lubricant,solvent cement PVC clips or burried underground i/c making necessary chases and holes in walls, floors or trenching complete with making good or i/c excavation and refilling as per site requirement with testing etc.complete. FOR WASH BASIN CONNECTION (40mm diameter) 975 18.6 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. 18.6.1 Internal work - Exposed on wall 18.6.1.1 15 mm nominal outer dia Pipes. 18.6.1.2 20 mm nominal outer dia .Pipes. 18.6.1.3 25 mm nominal outer dia .Pipes. 18.6.1.4 32 mm nominal outer dia Pipes. 18.6.1.5 40 mm nominal outer dia Pipes. 18.6.1.6 50 mm nominal outer dia .Pipes. 18.6.2 Concealed work including cutting chases and making good the walls etc. 18.6.2.1 15 mm nominal outer dia .Pipes. 18.6.2.2 20 mm nominal outer dia .Pipes. 18.6.2.3 25 mm nominal outer dia Pipes. 18.6.2.4 32 mm nominal outer dia Pipes. 976 18.7 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings. This included jointing of pipes and fittings with one step CPVC solvent cement, trenching, refilling and testing of joints complete as per direction of Engineer-in- Charge. External Work 18.7.1 15 mm nominal outer dia Pipes. 18.7.2 20 mm nominal outer dia .Pipes. 18.7.3 25 mm nominal outer dia Pipes. 18.7.4 32 mm nominal outer dia .Pipes. 18.7.5 40 mm nominal outer dia Pipes. 18.7.6 50 mm nominal outer dia .Pipes. 18.7.7 62.50 mm nominal inner dia Pipes. 18.7.8 75 mm nominal inner dia .Pipes. 18.7.9 100mm nominal inner dia .Pipes. 18.7.10 150 mm nominal inner dia Pipes. 977 18.8 Providing and fixing G.I. pipes complete with G.I. fittings and clamps, including cutting and making good the walls etc. 18.8.1 Internal work - Exposed on wall 18.8.1.1 15 mm dia. nominal bore 18.8.1.2 20 mm dia. nominal bore 18.8.1.3 25 mm dia. nominal bore 18.8.1.4 32 mm dia. nominal bore 18.8.1.5 40 mm dia. nominal bore 18.8.1.6 50 mm dia. nominal bore 18.8.2 Concealed pipe including painting with anti corrosivebitumastic paint, cutting chases and making good the wall. 18.8.2.1 15 mm dia nominal bore 18.8.2.2 20 mm dia nominal bore 18.8.3 External work : including trenching and refilling etc. 18.8.3.1 15 mm dia. nominal bore 18.8.3.2 20 mm dia. nominal bore 18.8.3.3 25 mm dia. nominal bore 18.8.3.4 32 mm dia. nominal bore 18.8.3.5 40 mm dia. nominal bore 18.8.3.6 50 mm dia. nominal bore 18.8.3.7 65 mm dia. nominal bore 18.8.3.8 80 mm dia. nominal bore 978 18.9 Providing and fixing Stainless Steel pipe and fitting of grade AISI 304 as per JIS standard 3448 complete with press type fitting (fitting shall be paid for separately) i/c fixing of the pipe with clamps at 1.00 m spacing including cutting and making good the walls including testing of joints complete as per direction of Engineer -in-charge. (The pipe length inserted in the fitting shall not be measured for payment) 18.9.1 Internal work - Exposed on wall 18.9.1.1 15.88 mm outer diapipe 18.9. 1.2 22.22 mm outer diapipe 18.9.1.3 28.58 mm outer diapipe 18.9.1.4 34.00 mm outer dia Pipe 18.9.1.5 42.70 mm outer dia Pipe 18.9.1.6 48.60 mm outer dia Pipe 18.9.2 Internal work - Concealed Pipe 18.9.2.1 15.88 mm outer dia .Pipes. 18.9.2.2 22.22 mm Outer diaPipes 979 18.12 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 18.12.1 With C.I. wheel of approved quality (screwed end) 18.12.1.1 25 mm nominal bore 18.12.1.2 32 mm nominal bore. 18.12.1.3 40 mm nominal bore 18.12.1.4 50 mm nominal bore 18.12.1.5 65 mm nominal bore 18.12.1.6 80 mm nominal bore 18.12.2 With brass lever handle of approved quality. 18.12.2.1 25 mm nominal bore 18.12.2.2 32 mm nominal bore. 18.12.2.3 40 mm nominal bore 18.12.2.4 50 mm nominal bore 980 18.13 Providing and fixing CPVC gate valve with knob of approved quality. 18.13.1 25 mm nominal bore 18.13.2 32 mm nominal bore. 18.13.3 40 mm nominal bore 18.13.4 50 mm nominal bore 981 18.14 Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 18.14.1 15 mm nominal bore 18.14.2 20 mm nominal bore 18.14 3 25 mm nominal bore 982 18.15 Providing and fixing gun metal non- return valve of approved quality (screwed end) : 18.15.1 25 mm nominal bore 18.15.1.1 Horizontal 18.15.1.2 Vertical 18.15.2 32 mm nominal bore 18.15.2.1 Horizontal 18.15.2.2 Vertical 18.15.3 40 mm nominal bore 18.15.3.1 Horizontal 18.15.3.2 Vertical 18.15.4 50 mm nominal bore 18.15.4.1 Horizontal 18.15.4.2 Vertical 18.15.5 65 mm nominal bore 18.15.5.1 Horizontal 18.15.5.2 Vertical 18.15.6 80 mm nominal bore 18.15.6.1 Horizontal 18.15.6.2 Vertical 983 18.16 Providing and fixing brass ferrule with C.I. mouth cover including boring and tapping the main : 18.16.1 15 mm nominal bore 18.16.2 20 mm nominal bore 18.16.3 25 mm nominal bore 984 18.17 Providing and fixing uplasticised PVC connection pipe with brass unions : 18.17.1 30 cm length 18.17.1.1 15 mm nominal bore 18.17.1.2 20 mm nominal bore 18.17.2 45 cm length 18.17.2.1 15 mm nominal bore 18.17.2.2 20 mm nominal bore 985 18.18 Constructing masonry Chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement :2 sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement :5 sand:10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement :3 sand) 12mm thick finished with a floating coat of neat cement complete as per standard design :- 18.18.1 With common burnt clay bricks of 25 kg /sqcm compressive strength. 18.18.2 With well burnt flyash bricks of 50 kg/sqm compressive strength. 986 18.19 Constructing masonry Chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 sand) for sluice valve, with C.I. surface box 100mm. top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement :2 sand : 4 graded stone aggregate 20mm nominal size ) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design 18.19.1 With common burnt clay bricks of 25 kg /sqcm compressive strength. 18.19.2 With flyash bricks of 50 kg/cm2 strength 987 18.20 Constructing masonry Chamber 60x60x75 cm, inside in brick work in cement mortar 1:4 (1 cement : 4 sand) for fire hydrants, with C.I. surface box 350x350 mm. top and 165 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 sand : 4 graded stone aggregate 20 mm nominal size) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 sand:10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design : 18.20.1 With common burnt clay bricks of 25 kg/cm2 compressive strength. 18.20.2 With flyash bricks of 50kg/cm2 strength. 988 18.21 Constructing masonry Chamber 60x45x50 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 sand) for water meter complete with C.I. double flap surface box 400x200x200 mm (inside) with locking arrangement and RCC top slab 1:2:4 mix (1 cement : 2 sand : 4 graded stone aggregate 20 mm nominal size) , i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 sand:10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design : 18.21.1 With common burnt clay bricks of 25 kg /sqcm compressive strength. 18.21.2 With flyash bricks of 50kg/sqm compressive strength. 989 18.22 Painting G.I. pipes and fittings with synthetic enamel white paint with two coats over a ready mixed priming coat, both of approved quality for new work : 18.22.1 15 mm diameter pipe. 18.22.2 20 mm diameter pipe. 18.22.3 25 mm diameter pipe. 18.22.4 32 mm diameter pipe. 18.22.5 40 mm diameter pipe. 18.22.6 50 mm diameter pipe. 990 18.23 Repainting G.I. pipes and fittings with synthetic enamel white paint of approved quality : 18.23.1 15 mm diameter pipe. 18.23.2 20 mm diameter pipe. 18.23.3 25 mm diameter pipe 18.23.4 32 mm diameter pipe 18.23.5 40 mm diameter pipe 18.23.6 50 mm diameter pipe 991 18.24 Painting G.I. pipes and fittings with two coats of anti-corrosive bitumastic paint of approved quality : 18.24.1 15 mm diameter pipe 18.24.2 20 mm diameter pipe 18.24.3 25 mm diameter pipe 18.24.4 32 mm diameter pipe 18.24.5 40 mm diameter pipe 18.24.6 50 mm diameter pipe 18.24.7 65 mm diameter pipe 18.24.8 80 mm diameter pipe 992 18.25 Providing and filling sand all-round the G.I. pipes in external work. 18.25.1 15 mm diameter pipe 18.25.2 20 mm diameter pipe 18.25.3 25 mm diameter pipe 18.25.4 32 mm diameter pipe 18.25.5 40 mm diameter pipe 18.25.6 50 mm diameter pipe 18.25.7 65 mm diameter pipe 18.25.8 80 mm diameter pipe 993 18.26 Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) 18.26.1 15 mm nominal bore 18.26.2 20 mm nominal bore 18.26.3 25 mm nominal bore 18.26.4 32 mm nominal bore 18.26.5 40 mm nominal bore 18.26.6 50mm nominal bore 18.26.7 65mm nominal bore 18.26.8 80 mm nominal bore 994 18.27 Providing and fixing G.I. Union in existing G.I. pipe line, cutting and threading the pipe and making long screws including excavation, refilling the earth or cutting of wall and making good the same complete wherever required : 18.27.1 15 mm nominal bore. 18.27.2 20 mm nominal bore. 18.27.3 25 mm nominal bore. 18.27.4 32 mm nominal bore. 18.27.5 40 mm nominal bore. 18.27.6 50 mm nominal bore. 18.27.7 65 mm nominal bore. 18.27.8 80 mm nominal bore. 995 18.28 Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank 996 18.29 Providing and fixing brass bib cock of approved quality 18.29.1 15 mm nominal bore 18.29.2 20 mm nominal bore 997 18.30 Providing and fixing brass stop cock of approved quality : 18.30.1 15 mm nominal bore 18.30.2 20 mm nominal bore 998 18.31 Providing and fixing C.P. brass bib cock of approved quality conforming to IS: 8931, and weighing not less then 400 kg, 15 mm nominal bore. 999 18.32 Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gm, 15 mm nominal bore. 1000 18.33 Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gm, 15 mm nominal bore 1001 18.34 Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS: 8931. 15 mm nominal bore. 1002 18.35 Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:893115 mm nominal bore 1003 18.36 Providing and fixing chrome plated brass battery based infrared sensor operated pillar cock, having foam flow technology. 15 mm nominal bore. 1004 18.37 Providing and fixing C.P. brass pillar cock approved quality and make conforming to IS: specification. nd weighing not less than 650 gm,a15 mm nominal bore 125 mm long foam flow. 1005 18.38 Providing and fixing C.P. brass basin mixer of approved quality and make conforming to IS: specification.15 mm nominal bore. 1006 18.39 Providing and fixing C.P. brass wall mixer of approved quality and make conforming to IS: specification. 15 mm nominal bore. 1007 18.40 Providing and fixing C.P. brass sink mixer of approved quality and make conforming to IS: specification. 15 mm nominal bore. 1008 18.41 Providing and fixing C.P. brass elbow operated bibcock of approved quality and make conforming to IS: specification. 15 mm nominal bore. 1009 18.42 Providing and fixing C.P. brass elbow operated pillar cock of approved quality and make conforming to IS: specification. 15 mm nominal bore. 1010 18.43 Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : 18.43.1 100 mm diameter 18.43.2 150 mm diameter 18.43.3 200 mm diameter 1011 18.44 Providing and fixing PTMT bib cock of approved quality and colour 15mm nominal bore. 18.44.1 86 mm long weighing not less than 88 gm 18.44.2 122 mm long weighing not less than 99 gm 18.44.3 165mm long weighing not less than 110 gm 18.44.4 90mm long weighing not less than 93 gm 1012 18.45 Providing and fixing PTMT stop cock of approved quality and colour. 18.45.1 15 mm nominal bore, 86mm long. Weighing not less than 88 gms. 18.45.2 20mm nominal bore, 89mm long. Weighing not less than 88 gms. 18.45.3 Concealed stop cock, 15mm nominal bore, 108mm long. Weighing not less than 108 gms. 1013 18.46 Providing and fixing PTMT pillar cock of approved quality and colour. 18.46.1 15mm nominal bore, 107mm long. Weighing not less than 110 gms. 18.46.2 15mm nominal bore, 125mm long foam flow weighing not less than 120 gms. 1014 18.47 Providing and fixing PTMT, push cock of approved quality and colour. 18.47.1 15 mm nominal bore, 98mm long. Weighing not less than 75 gms. 18.47.2 15 mm nominal bore, 80mm long weighing not less than 46 gms. 1015 18.48 Providing and fixing PTMT grating of approved quality and colour. 18.48.1 Circular type. 18.48.1.1 100 mm nominal dia. 18.48.1.2 125 mm nominal dia with 25 mm waste hole. 18.48.2 Rectangular type with openable circular lid. 18.48.2.1 150 mm nominal size square 100 mm diameter of the inner hinged round grating. 1016 18.49 Providing and fixing PTMT angle stop cock 15 mm nominal bore. Weighing not less than 85 gms. 1017 18.50 Providing and fixing PTMT swivelling shower, 15mm nominal bore. Weighing not less than 40gms. 1018 18.51 Providing and fixing PTMT Ball cock of approved quality, colour and make complete with Epoxy coated aluminium rod with L.P./ H.P.H.D. plastic ball. 18.51.1 15 mm nominal bore, 105 mm long. Weighing not less than 138 gms. 18.51.2 20 mm nominal bore, 120 mm long. Weighing not less than 198 gms. 18.51.3 25 mm nominal bore, 152mm long. Weighing not less than 440 gms. 18.51.4 40mm nominal bore, 206mm long. Weighing not less than 690 gms. 18.51.5 50mm nominal bore, 242mm long. Weighing not less than 1240 gms. 1019 18.52 Providing and fixing Unplasticised P.V.C. connection pipe with PTMT Nuts collar and bush of approved quality and colour 15 mm nominal bore 18.52.1 30cm length. 18.52.2 45 cm length. 1020 18.53 Providing and fixing PTMT extension nipple for water tank pipe, fittings of approved quality and colour. 18.53.1 15 mm nominal bore.Weighing not less than 32 gms. 18.53.2 20mm nominal bore.Weighing not less than 40gms. 18.53.3 25mm nominal bore.Weighing not less than 62 gms. 1021 18.54 Providing and fixing enclosed type water meter (bulk type) conforming to IS: 2373 and tested by Municipal Board complete with bolts, nuts, rubber insertions etc. (The tail pieces if required will be paid separately) : 18.54.1 80 mm nominal bore 18.54.2 100 mm nominal bore 18.54.3 150 mm nominal bore 18.54.4 200 mm nominal bore 1022 18.55 Providing and fixing C.I. dirt box strainer for bulk type water meter with nuts, bolts, rubber insertions etc. complete conforming to IS : 2373 : 18.55.1 80 mm nominal bore 18.55.2 100 mm nominal bore 18.55.3 150 mm nominal bore 18.55.4 200 mm nominal bore 1023 18.56 Cutting holes upto 30x30 cm in walls including making good the same : With common burnt clay bricks of 25 kg /sqcmor flyash bricks of 50 kg/cm2compressive strength. 1024 18.57 Cutting holes upto 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 sand : 4 graded stone aggregate 20 mm nominal size) including finishing complete so as to make it leak proof. 1025 18.58 Making chases upto 7.5x7.5 cm in walls including making good and finishing with matching surface after housing G.I. pipe etc. 1026 18.59 Making hole upto 20x20 cm and embedding pipes upto 150 mm diameter in masonry and filling with cement concrete 1:3:6 (1 cement : 3 sand : 6 graded stone aggregate 20 mm nominal size) including disposal of malba. 1027 18.60 Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete : 18.60.1 25 to 40 mm nominal bore 18.60.2 50 to 80 mm nominal bore 1028 18.61 Providing and fixing CP jet assembly to including connection etc complete. 1029 18.62 Providing and fixing ferro- cement water storage tank with cover, having minimum thickness of 10mm. The wall to be reinforced with two layers of double galvanized annealed square wooven wire mesh of 20 gauge wire spaced at 15mm for 300 litre capacity and 12mm for 450 to 2500 litres capacity finish with 3 layers of Cement mortar 1:2 duly modified with polymer based plastizers and hardening chemicals (Burogrout and Buroseal) The tank should conform to the specification prescribed by Structural Engineering Research Centre Roorkee/Gaziabad. The tanks to be painted with drinking water paint inside and aluminimum paint out side with provision of outlet, inlet, overflow and cleaning including hoisting and placing in position upto floor two level or 5 M. height. 1030 18.63 Add extra for additional floor lift beyond 5.0M.height. 1031 19.1 Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 sand) including testing of joints etc. complete : Excavation to be paid seperataly 19.1.1 100 mm diameter 19.1.2 150 mm diameter 19.1.3 200 mm diameter 19.1.4 230 mm diameter 19.1.5 250 mm diameter 19.1.6 300 mm diameter 1032 19.2 Providing and laying cement concrete 1:5:10 (1 cement : 5 sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design: 19.2.1 100 mm diameter S.W. pipe 19.2.2 150 mm diameter S.W. pipe 19.2.3 200 mm diameter S.W. pipe 19.2.4 230 mm diameter S.W. pipe 19.2.5 250 mm diameter S.W. pipe 19.2.6 300 mm diameter S.W. pipe 1033 19.3 Providing and laying cement concrete 1:5:10 (1 cement : 5 sand : 10 graded stone aggregate 40 mm nominal size) upto haunches of S.W. pipes including bed concrete as per standard design : 19.3.1 100 mm diameter S.W. pipe 19.3.2 150 mm diameter S.W. pipe 19.3.3 200 mm diameter S.W. pipe 19.3.4 230 mm diameter S.W. pipe 19.3.5 250 mm diameter S.W. pipe 19.3.6 300 mm diameter S.W. pipe 1034 19.4 Providing and laying below ground unplasticised PVC pipe to with stand working pressure of 4 kg/cm2 soild waste pipes confirming to IS:13592 and IS:4985 including jointing with seal ring confirming to IS :5282 leaving 10mm gap for thermal expansion all necessary fittings etc. complete. Excavation to be paid seperataly. 19.4.1 110 mm diameter OD (min. wall thickness 3.2mm) 19.4.2 160 mm diameter OD (min. wall thickness 4.0mm) 19.4.3 200 mm diameter OD (min. wall thickness 4.9mm) 19.4.4 250 mm diameter OD (min. wall thickness 6.2mm) 19.4.5 300 mm diameter OD (min. wall thickness 7.7mm) 1035 19.5 Providing and laying cement concrete 1:3:6 (1 cement: 3 sand: 6 graded stone aggregate 20 mm nominal size) all-round PVC. pipes including bed concrete as per standard design: 19.5.1 110 mm diameter PVC. pipe 19.5.2 160 mm diameter PVC. pipe 19.5.3 200 mm diameter PVC. pipe 19.5.4 250 mm diameter PVC. pipe 19.5.5 300 mm diameter PVC pipe 1036 19.6 Providing and laying cement concrete 1:3:6 (1 cement : 3 sand : 6 graded stone aggregate 20 mm nominal size) up to haunches of PVC. pipes including bed concrete as per standard design : 19.6.1 110 mm diameter PVC. pipe 19.6.2 160 mm diameter PVC. pipe 19.6.3 200 mm diameter PVC. pipe 19.6.4 250 mm diameter PVC. Pipe 19.6.5 300 mm diameter PVC pipe 1037 19.7 Providing and fixing square- mouth S.W. gully trap class SP1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design : 19.7.1 100x100 mm size P type 19.7.1.1 With well burnt bricks 19.7.1.2 With Sewer bricks conforming to IS : 4885 19.7.2 150 x 100 mm size P type. 19.7.2.1 With well burnt bricks 19.7.2.2 With sewer bricks conforming to IS : 4885 19.7.3 180x150 mm size P type 19.7.3.1 With well burnt bricks 19.7.3.2 With Sewer bricks conforming to IS : 4885 1038 19.8 Providing and laying non- pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 sand) including testing of joints etc. complete : 19.8.1 100 mm dia. R.C.C. pipe 19.8.2 150 mm dia. R.C.C. pipe 19.8.3 250 mm dia. R.C.C. pipe 19.8.4 300 mm dia. R.C.C. pipe 19.8.5 450 mm dia. R.C.C. pipe 19.8.6 500 mm dia. R.C.C. pipe 19.8.7 600 mm dia. R.C.C. pipe 1039 19.9 Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 sand ) R.C.C. top slab with Cement Concrete 1:2:4 mix (1 cement : 2 sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:2:4 mix (1 cement : 2 sand : 4 graded stone aggregate 20mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement : 3 sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement complete as per standard design 19.9.1 Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : 19.9.1.1 With well burnt bricks 19.9.1.2 With Sewer bricks conforming to IS : 4885 19.9.2 Inside size 120x90 cm and 90 cm deep including C.I. cover with frame (medium duty) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg (weight of cover 58 kg and weight of frame 58 kg) : 19.9.2.1 With well burnt bricks 19.9.2.2 With Sewer bricks conforming to IS : 4885 19.9.3 Inside size 120x90 cm and 90 cm deep including C.I. cover with frame (heavy duty) 560 mm internal diameter, total weight of cover and frame to be not less than 208 kg (weight of cover 108 kg and weight of frame 100 kg) : 19.9.3.1 With well burnt bricks 19.9.3.2 With Sewer bricks conforming to IS : 4885 1040 19.10 Extra for depth for manholes 19.10.1 Size 90x80 cm 19.10.1.1 With well burnt bricks 19.10.1.2 With Sewer bricks conforming to IS : 4885 19.10.2 Size 120x90 cm 19.10.2.1 With well burnt bricks 19.10.2.2 With Sewer bricks conforming to IS : 4885 1041 19.11 Constructing brick masonry circular type manhole 0.91m internal dia at bottom and 0.56m dia at top in cement mortar 1:4 (1 cement : 4 sand), inside cement plaster 12 mm thick with cement mortar 1:3 (1 cement : 3 sand) finished with a floating coat of neat cement, foundation concrete 1:3:6 mix (1 cement : 3 sand : 6 graded stone aggregate 40mm nominal size), and making necessary channel in cement concrete 1:2:4 (1 cement : 2 sand : 4 graded stone aggregate 20 mm nominal size) including centering shuttering all complete. (Foot rests and 12mm thick cement plaster at the external surface shall be paid for separately) : 19.11.1 With well burnt bricks 19.11.2 With Sewer bricks conforming to IS : 4885 1042 19.12 Extra depth for circular type manhole 0.91m internal dia (at bottom) beyond 0.91m to 1.67m 19.12.1 With well burnt bricks 19.12.2 With Sewer bricks conforming IS : 4885 1043 19.13 Constructing brick masonry circular manhole 1.22m internal dia at bottom and 0.56m dia at top in cement mortar 1:4 (1 cement :4 sand) inside cement plaster 12mm thick with cement mortar 1:3 (1 cement :3 sand) finished with a floating coat of neat cement foundation concrete 1:3:6 (1 cement : 3 sand : 6 graded stone aggregate 40mm nominal size) and making necessary channel in cement concrete 1:2:4 including centering shuttering all complete. (Foot rests and 12 mm thick cement plaster at the external surface shall be paid for separately) 19.13.1 With well burnt bricks 19.13.2 With Sewer bricks conforming IS : 4885 1044 19.14 Extra depth for circular type manhole 1.22m internal dia (at bottom) beyond 1.68 m to 2.29 m : 19.14.1 With well burnt bricks 19.14.2 With Sewer bricks conforming IS : 4885 1045 19.15 Constructing brick masonry circular manhole 1.52 m internal dia at bottom and 0.56 m dia at top in cement mortar 1:4 (1 cement : 4 sand) inside cement plaster 12mm thick with cement mortar 1:3 (1 cement : 3 sand) finished with a floating coat of neat cement, foundation concrete 1:3:6 (1 cement : 3 sand : 6 graded stone aggregate 40mm nominal size) and making necessary channel in cement concrete 1:2:4 (1 cement : 2 sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement all complete as per standard design : 19.15.1 2.30m deep with SFRC Cover and frame (heavy duty HD-20 grade designation) 560mm internal diameter conforming to I.S. 12592, total weight of cover and frame to be not less than 182 kg. fixed in cement concrete 1:2:4 (1 cement : 2 sand : 4 graded stone aggregate 20mm nominal size) including centering shuttering all complete. (Foot rests and 12 mm thick cement plaster at the external surface shall be paid for separately) : 19.15.1.1 With well burnt bricks 19.15.1.2 With Sewer bricks conforming IS : 4885 1046 19.16 Extra depth for circular type manhole 1.52 m internal dia (at bottom) beyond 2.30 m : 19.16.1 With well burnt bricks 19.16.2 With Sewer bricks conforming IS : 4885 1047 19.17 Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement : 3 sand : 6 graded stone aggregate 20 mm nominal size) as per standard design : 19.17.1 With 20x20 mm square bar 19.17.2 With 20 mm diameter round bar 1048 19.18 Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS : 10910 on 12mm dia steel bar conforming to IS : 1786 having minimum cross section as 23 mmx25mm and over all minimum length 263 mm as per standard drawing and suitable to withstand the bend test and chemical resistance test as per specifications and having manufactures permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 sand : 6 graded stone aggregate 20 mm nominal size) complete as per design. 1049 19.19 Replacement of M.S. foot rests in manholes including dismantling concrete blocks and fixing with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement : 3 sand : 6 graded stone aggregate 20 mm nominal size): 19.19.1 With 20x20 mm square bar 19.19.2 With 20 mm diameter round bar 1050 19.20 Supplying and fixing C.I. cover without frame for manholes : 19.20.1 455x610 mm rectangular C.I. cover (light duty) the weight of the cover to be not less than 23 kg. 19.20.2 500 mm diameter C.I. cover (medium duty) the weight of the cover to be not less than 58 kg. 19.20.3 560 mm diameter C.I. cover (heavy duty) the weight of the cover to be not less than 108 kg. 1051 19.21 Providing and fixing in position precast R.C.C. manhole cover and frame of required shape and approved quality 19.21.1 Light duty D- 2.5 19.21.1.1 Rectangular shape 600x450mm internal dimensions 19.21.1.2 Square shape 450mm internal dimensions 19.21.1.3 Circular shape 450mm internal diameter 19.21.2 Medium duty - 10 19.21.2.1 Square shape 450mm internal dimension 19.21.2.2 Circular shape 500mm internal diameter 19.21.3 Heavy duty D - 20 19.21.3.1 Circular shape 560 mm internal diameter 19.21.4 Extra Heavy Duty - 35 19.21.4.1 Circular shape 560 mm internal dia. 1052 19.22 Supplying and fixing C.I. cover 300x300 mm without frame for gully trap (standard pattern) the weight of cover to be not less than 4.5kg. 1053 19.23 Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement : 3 sand) finished with a floating coat of neat cement and making necessary channels for the drain etc. complete : 19.23.1 For pipes 100 to 230 mm diameter 19.23.2 For pipes 250 to 300 mm diameter 19.23.3 For pipes 350 to 450 mm diameter 1054 19.24 Providing sand cast iron drop connection externally for 60 cm drop from branch sewer line to main sewer manhole including inspection and cleaning eye with chain and lid, sand cast iron drop pipe and bend encased all-round with cement concrete 1:5:10 (1 cement : 5 sand : 10 graded stone aggregate 40 mm nominal size) with cement mortar 1:1 (1 cement : 1 sand) joints between sand cast iron tee and S.W. pipe, making required channels complete as per standard design and specifications : 19.24.1 100 mm dia. sand cast iron drop connection 19.24.2 150 mm dia. sand cast iron drop connection 1055 19.25 Extra for depths beyond 60 cm of sand cast iron drop connection complete : 19.25.1 For 100 mm dia. sand cast iron drop connection 19.25.2 For 150 mm dia. sand cast iron drop connection 1056 19.26 Raising manhole cover and frame slab to required level including dismantling existing slab and making good the damage as required (Brick work for Raising depth of manhole to be paid separately) : 19.26.1 Rectangular manhole 90x80 cm with rectangular cover 600x450 mm of grade LD - 2.5 19.26.2 Rectangular manhole 120x90 cm with circular cover 500 mm dia of grade MD - 10 19.26.3 Rectangular manhole 120x90 cm with circular cover 560 mm dia of grade HD - 20 19.26.4 Circular manhole 140 cm dia with circular cover 600 mm dia of grade Extra heavy duty HD -35 1057 19.27 Constructing brick masonry road gully chamber 50x45x60cm with bricks in cement mortar 1:4 (1 cement : 4 sand) including 500x450 mm precast R.C.C. horizontal grating with frame complete as per standard design : 19.27.1 With well burnt bricks 19.27.2 With fly ash bricks 100 key/cm2 strangth 1058 19.28 Constructing brick masonry road gully chamber 45x45x77.5cm with bricks in cement mortar 1:4 (1 cement : 4 sand) with precast R.C.C. vertical grating complete as per standard design : 19.28.1 With well burnt bricks 19.28.2 With fly ash bricks 100 kg/cm2 strength 1059 19.29 Constructing brick masonry road gully chamber 110x50x77.5cm with bricks in cement mortar 1:4 (1 cement : 4 sand) including 500x450 mm precast R.C.C. horizontal grating with frame and vertical grating complete as per standard design : 19.29.1 With well burnt bricks 19.29.2 With fly ash bricks 100 kg/cm2 strength 1060 19.30 Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks of class designation 75 and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design. 19.30.1 With well burnt bricks 1061 19.31 Constructing soak pit 1.20x1.20x1.20m filled with brickbats including S.W. drain pipe 100 mm diameter and 1.20m long complete as per standard design. 1062 19.32 Providing and fixing S.W. intercepting trap in manholes with stiff mixture of cement mortar 1:1 (1 cement : 1 sand) including testing of joints etc. complete : 19.32.1 100 mm dia 19.32.2 150 mm dia 1063 19.33 Providing, laying and jointing half round glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 sand) including testing of joints etc. complete : Excavation to be paid seperataly 19.33.1 100 mm dia 19.33.2 150 mm dia 19.33.3 200 mm dia 19.33.4 230 mm dia 19.33.5 250 mm dia 19.33.6 300 mm dia 1064 19.34 Providing and laying half round RCC pipes class (light duty) with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 sand) including testing of joints etc. complete : Excavation to be paid seperataly 19.34.1 100 mm dia. Half round R.C.C. pipe 19.34.2 150 mm dia. Half round R.C.C. pipe 19.34.3 250 mm dia. Half round R.C.C. pipe 19.34.4 300 mm dia. Half round R.C.C. pipe 1065 19.35.1 Deduct for not provide C.I. manhole cover with frame for item No. 19.9.1.1 & 19.9.1.2 19.35.2 Deduct for not provide C.I. manhole cover with frame for item No. 19.9.2.1 & 19.9.2.2 19.35.3 Deduct for not provide C.I. manhole cover with frame for item No. 19.9.3.1 & 19.9.3.2 1066 19.36 Providing & Fixing of Precast RCC drain cover of size 600x 450 x70mm (thickness) with 4 holes, manufactured by using M-30 grade of concrete reinforced with 8mm dia Tor Steel @100mm c/c both ways, manufactured by vibro compaction process using joint less FRP moulds, so at to achieve shuttering finish on five faces @top face will have broom finish etc complete. 1067 19.37 Providing & Fixing of Precast RCC drain cover of size 750x600 x70mm (thickness) with 6 holes, manufactured by using M-30 grade of concrete reinforced with 8mm dia Tor Steel @100mm c/c both ways, manufactured by vibro compaction process using joint less FRP moulds, so at to achieve shuttering finish on five faces @top face will have broom finish etc complete. 1068 19.38 Providing & Fixing of Precast RCC drain cover of size 900x450 x90mm (thickness) with 8 holes, manufactured by using M-30 grade of concrete reinforced with two layers of 8mm dia Tor Steel @100mm c/c both ways, manufactured by vibro compaction process using joint less FRP moulds, so at to achieve shuttering finish on five faces @ top face will have broom finish etc complete. 1069 19.39 Providing & Fixing of Precast RCC drain cover of size 1150x400 x100mm (thickness) with 10 holes, manufactured by using M-30 grade of concrete reinforced with two layers of 8mm dia Tor Steel @100mm c/c both ways, manufactured by vibro compaction process using joint less FRP moulds, so at to achieve shuttering finish on five faces @top face will have broom finish etc complete. 1070 19.40 Supplying and fixing of FRP/GRP composite manhole cover with frame of clear opening size 900X450mm rectangular having weight of (complete unit) (weight of frame 11.7 kg + weight of cover 43.76kg ± 10%) (HD/25MT) having load bearing capacity (Point load 25MT) as per testing code BSEN 124:1994. Having lifting arrangement should have an insertion of 5mm double sealed closed key hole and high strength plastic alloy/stainless steel socketed arrangement. 1071 19.41 Supplying and fixing of FRP/GRP composite manhole cover with frame of clear opening size 450X600mm rectangular having weight of (complete unit) (weight of frame 1.84kg + weight of cover 14.2kg ± 10%) (LD/2.5MT) having load bearing capacity (Point load 2.5MT) as per testing code BSEN 124:1994. having lifting arrangement should have an insertion of 5mm double sealed closed key hole and high strength plastic alloy/stainless steel socketed arrangement. 1072 19.42 Supplying and fixing of FRP/GRP composite manhole cover with frame of clear opening size 300X300mm (square) having weight of (complete unit) (weight of frame 1.12kg + weight of cover 4.1kg ± 10%) (LD/2.5MT) having load bearing capacity (Point load 2.5MT) as per testing code BSEN 124:1994. having lifting arrangement should have an insertion of 5mm double sealed closed key hole and high strength plastic alloy/stainless steel socketed arrangement. 1073 19.43 Supplying and fixing of FRP/GRP composite manhole cover with frame of clear opening size 600mm (round) having weight of (complete unit) (weight of frame 13.6kg + weight of cover 43.1kg + - 10%) (HD/25MT) having load bearing capacity (Point load 25MT) as per testing code BSEN 124:1994. having lifting arrangement should have an insertion of 5 mm double sealed closed key hole and high strength plastic alloy/stainless steel socketed arrangement 1074 19.44 Supplying and fixing of FRP/GRP composite manhole cover with frame of clear opening size 500mm (round) having weight of (complete unit) (weight of frame 11.2kg + weight of cover 41.78kg ± 10%) (HD/25MT) having load bearing capacity (Point load 25MT) as per testing code BSEN 124:1994. Having lifting arrangement should have an insertion of 5mm double sealed closed key hole and high strength plastic alloy/stainless steel socketed arrangement 1075 19.45 Deduct for not providing and installing FRP/GRP manhole cover size 19.45.1 900mmx450mm (weight of cover 43.76kg ± 10%) 19.45.2 450mmx600mm (weight of cover 14.2kg ± 10%) 19.45.3 300mmx300mm (weight of cover 4.1kg ± 10%) 19.45.4 600mm (weight of cover 41.78kg ± 10%) 19.45.5 500mm (weight of cover 43.1kg ± 10%) 1076 19.46 Providind, laying and jointing HDPE Double Wall corrugated (DWC) pipes (excavation to be paid seperately) 19.46.1 100 mm dia to 110 mm dia 19.46.2 150 mm dia to 160 mm dia 19.46.3 200 mm dia 19.46.4 250 mm dia 19.46.5 300 mm dia 1077 21.1 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : 21.1.1 For fixed portion. 21.1.1.1 Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC15) 21.1.1.2 Powder coated aluminium (minimum thickness of powder coating 50 micron) 21.1.1.3 Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micron) 21.1.2 For shutters of doors, windows and ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately). 21.1.2.1 Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC15) 21.1.2.2 Powder coated aluminium (minimum thickness of powder coating 50 micron) 21.1.2.3 Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micron) 21.1.3 Deduct for not providing EDPM rubber/neoprene gasket all around. 1078 21.2 Providing and fixing 12mm thick Pre-laminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminium doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in-charge. 21.2.1 Pre-laminated particle board with decorative lamination on one side and balancing lamination on other side. 21.2.2 Pre-laminated particle board with decorative lamination on both sides. 1079 21.3 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber/ neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge. (Cost of aluminium snap beading shall be paid in basic item) : 21.3.1 With float glass panes of 4.0 mm thickness (weight not less than 10 kg/sqm) 21.3.2 With float glass panes of 5.0 mm thickness (weight not less than 12.50 kg/sqm ) 21.3.3 With float glass panes of 8 mm thickness (weight not less than 20 kg/sqm ). 1080 21.4 Add extra for providing and fixing froasted glass instead of float glass 21.4.1 With glass panes of 4.0 mm thickness (weight not less than 10 kg/sqm) 21.4.2 With glass panes of 5.0 mm thickness (weight not less than 12.50 kg/sqm ) 21.4.3 With glass panes of 8 mm thickness (weight not less than 20 kg/sqm ). 1081 21.5 Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body /plate with double spring mechanism and door weight upto 125 kg., for doors, including cost of cutting floors , embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge : 21.5.1 With stainless steel cover plate - minimum 1.25 mm thickness 21.5.2 With brass cover plate - minimum 1.25 mm thickness. 1082 21.6 Providing and fixing powder coated aluminium work (minimum thickness of powder coating 50 micron) consisting of tee/ angle sections, of approved make conforming to IS : 733 in frames of false ceiling including aluminium angle cleats with necessary C.P. brass/ stainless steel sunk screws, aluminium perimeter angles fixed to wall with stainless steel rawl plugs @ 450 mm centre to centre and fixing the frame work to G.I. level adjusting hangers 6 mm dia. with necessary cadmium plated machine screws all complete as per approved architectural drawings and direction of the Engineer-in-charge (level adjusting hangers, ceiling cleats and expansion hold fasteners to be paid for separately). 1083 21.7 Providing and fixing 6 mm dia. G.I. level adjusting hangers (upto 1200mm length), fixed to roof slabs by means of ceiling cleats made out of G.I. flat 40x3mm size 60 mm long and stainless steel expandable dash fastener of 12.5 mm dia and 50 mm long, complete as per direction of Engineer -in-charge. 1084 21.8 Providing and fixing machine moulded aluminium covering of approved pattern and design, made out of machine cut aluminium sheet and machine holed for receiving dash fastener, over expansion joints on vertical surfaces/ceiling floors, the fixing on plate in one row on one side of joint only shall be done with stainless steel dash fasteners of 8 mm dia and 75 mm long bolt including providing aluminium washers 2 mm thick and 15 mm dia, at a staggered pitch of 200mm centre to centre including drilling holes in the receiving surface and providing expandable plastic sleeves in holes etc. complete as per direction of Engineer-in-Charge : 21.8.1 Anodised aluminium sheet 2.5mm thick (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) 21.8.2 Powder coated aluminium sheet 2.5mm thick (minimum thickness of powder coating 50 micron) 1085 21.9 Filling the gap in between aluminium frame and adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete. Upto 5 mm depth and 5 mm width 1086 21.10 Extra for applying additional anodic coating AC 25 instead of AC 15 to aluminium extruded sections. For fixed portion & for shutters of doors, windows and ventilators 1087 21.11 Providing and fixing double glazed hermetically sealed glazing in aluminium windows, ventilators and partition etc. with 6 mm thick clear float glass both side having 12 mm air gap including providing EPDM gasket, perforated aluminium spacers, desiccants, sealant (Both primary and secondary sealant ) etc. as per specifications, drawings and direction of Engineer-in-Charge complete. 1088 21.12 Providing and fixing aluminium tubular handle bar 32 mm outer dia, 3.0 mm thick and length as required with SS screws etc complete as per direction of Engineer-in-Charge. 21.12.1 Anodized (AC 15 ) aluminium tubular handle bar 21.12.2 Powder coated minimum thickness 50 micron aluminium tubular handle bar. 21.12.3 Polyester powder coated minimum thickness 50 micron aluminium tubular handle bar. 1089 21.13 Providing and fixing Brass 100 mm mortice latch and lock with 6 levers without pair of handles (best make of approved quality) for aluminium doors including necessary cutting and making good etc. complete. 1090 21.14 Providing and fixing anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868. Minimum anodic coating of grade AC15) sub frame work for windows and ventilators with extruded built up standard tubular sections of approved make conforming to IS: 733 and IS: 1285, fixed with dash fastener of required dia and size (Dash fastener to be paid for separately). 1091 21.15 Providing and fixing aluminium casement windows fastener of required length for aluminium windows with necessary screws etc. complete. 21.15.1 Anodized (AC15) aluminium 21.15.2 Powder coated minimum thickness 50 micron aluminium. 21.15.3 Polyester powder coated minimum thickness 50 micron aluminium. 1092 21.16 Providing and fixing aluminium round shape handle of outer dia 100mm with SS screws etc. Complete as per direction of Engineer-in-Charge 21.16.1 Anodized (AC15 ) aluminium 21.16.2 Powder coated minimum thickness 50 micron aluminium 21.16.3 Polyester powder coated minimum thickness 50 micron aluminium. 1093 21.17 Providing and fixing anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer-in-Charge. (Only weight of grill to be measured for payment). 1094 21.18 Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double action hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-Charge (Door handle, lock and stopper etc.to be paid separately). 1095 21.19 Providing and fixing 50 micron thick reflective one way type heat /light control film to window/door glazing with complete accessories as per direction of Engineer-in-charge of approved brand and make. 1096 21.20 Providing and fixing 50 micron thick Frosted heat /light control film to window/door glazing with complete accessories as per direction of Engineer-in-charge of approved brand and make. 1097 21.21 Providing and fixing 25 micron thick Non reflective heat /light control film to window/door glazing with complete accessories as per direction of Engineer-in- charge of approved brand and make. 1098 21.22 Providing and fixing 12 mm thick toughened glass including all connectors and fixing accessories all complete for partitions, cubicals etc. As per direction of Engineer-in-Charge. 1099 21.24 Extra for froasted glass (with eching film) in item No. 21.22 1100 22.1 Providing and laying integral cement based treatment for water proofing on horizontal surface at all depth below ground level for under ground structures as directed by Engineer-in-Charge consisting of: (i)     Ist layer of 22mm to 25mm thick approved and specified rough stone slab over a 25mm thick base of cement mortar 1:3 (1 cement: 3 sand) mixed with water proofing compound conforming to IS: 2645 in the recommended proportion over the levelling course ( levelling course to be paid separately). Joints sealed and grouted with cement slurry mixed with water proofing compound. (ii)         2nd layer of 25mm thick cement mortar 1:3 (1 cement: 3 sand) mixed with water proofing compound in recommended proportions. (iii)        Finishing top with stone aggregate of 10mm to 12mm nominal size spreading @ 8 cudm/sqm thoroughly embedded in the 2nd layer. (with 5 years service guarantee) Using rough Kota stone. 1101 22.2 Providing and laying integral cement based treatment for water proofing on the vertical surface by fixing specified stone slab 22 mm to 25mm thick with cement slurry mixed with water proofing compound conforming to IS:2645 in recommended proportions with a gap of 20mm (minimum) between stone slabs and the receiving surfaces and filling the gaps with neat cement slurry mixed with water proofing compound and finishing the exterior of stone slab with cement mortar 1:3 (1 cement : 3 sand) 20 mm thick with neat cement punning mixed with water proofing compound in recommended proportion complete at all levels and as directed by Engineer-in-charge (with 5 years service guarantee) Using rough Kota stone. 1102 22.3 Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen and the like consisting of : a)   Ist course of applying cement slurry @ 4.4 Kg/sqm mixed with water proofing compound conforming to IS 2645 in recommended proportions including rounding off junction of vertical and horizontal surface. b)   IInd course of 20mm cement plaster 1:3 (1 cement: 3 sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface. c)    IIIrd course of applying blown or residual bitumen applied hot at 1.7 Kg. per sqm of area. d)      IVth course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 Kg/sqm.) (with 5 years service guarantee) 1103 22.4 Providing and Placing in position suitable PVC water stops conforming to IS:12200 for construction/ expansion joints between two RCC members and fixed to the reinforcement with binding wire before pouring concrete etc. complete (with 5 years service guarantee) 22.4.1 Serrated with central bulb (225mm wide, 8- 11mm thick). 22.4.2 Dumb bell with central bulb (180mm wide, 8mm thick). 22.4.3 Kickers (320mm wide, 5mm thick). 1104 22.5 Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a)  First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b)  Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. 1105 22.6 Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying : a)     After surface preparation, first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. b)    Laying second layer of Fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm. c)   Third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/sqm mixed with water proofing cement compound @ 0.670 kg/sqm and sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30cm on parapet wall and tucked into groove in parapet all around. 1106 22.7 Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: a)  Applying a slurry coat of neat cement using 2.75 kg/sqm. of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300mm height including cleaning the surface before treatment. b)  Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115mm size with 50% of cement mortar 1:5 (1 cement : 5 sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-Charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-Charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. c) After two days of proper curing applying a second coat of cement slurry using 2.75kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-Charge. d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement: 4 sand) admixed with water proofing compound conforming to IS: 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3mm deep. e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by the Engineer-in- Charge: (with 5 years service guarantee) With average thickness of 120mm and minimum thickness at khurra as 65 mm. 1107 22.8 Providing and laying four courses water proofing treatment with bitumen felt over roofs consisting of first and third courses of blown bitumen 85/25 or 90/15 conforming to IS : 702 applied hot @ 1.45 Kg per square metre of area for each course, second course of roofing felt type 3 grade-I (hessian based self finished bitumen felt) and fourth and final course of stone grit 6mm and down size or pea-sized gravel spread at 6 cubic decimeter per square metre including preparation of surface but excluding grading complete with : (with five years service gurantee). Bitumen felt (hessian base) type 3 grade I conforming to IS: 1322. 1108 22.9 Providing and laying six courses water proofing treatment with bitumen felt over roofs consisting of first, third and fifth course of blown bitumen 85/25 or 90/15 conforming to IS : 702 applied hot @ 1.45, 1.20 and 1.45 Kg per square metre of area respectively, second and fourth courses of roofing felt type 3 grade I conforming to IS : 1322 (Hessian based self finished bitumen felt) conforming to IS : 1322 and sixth and final course of stone grit 6 mm and down size or pea sized gravel spread at 6 cubic dm per sqm including preparation of surface but excluding grading, complete. (With five years service gurantee). 1109 22.10 Providing and laying six courses water proofing treatment with bitumen felt over roofs consisting of first, third and fifth courses of blown or / and residual bitumen applied hot at 1.45, 1.20 and 1.70 kg per square metre of area respectively, second and fourth courses of roofing felt type 2 grade I (fibre base self finished bitumen felt) six and final courses of stone grit 6 mm and down size or pea sized gravel spread at 6cu.dm per sqm including preparation of surface, excluding grading, complete. (With five years service gurantee). 1110 22.11 Providing and laying six courses water proofing treatment with bitumen felt over roofs consisting of first, third and fifth courses of blow or/ and residual bitumen applied hot at 1.45, 1.20 and 1.70 kg per square metre of area respectively, second and fourth courses of roofing felt type 2 grade II (glass fibre base self finished bitumen felt) and sixth and final course of stone grit 6 mm and down size or pea sized gravel spread at 6 cubic dm per sqm including preparation of surface but excluding grading, complete. (With five years service gurantee) 1111 22.12 Deduct for omitting in water proofing treatment final course of spreading stone grit 6mm down size or pea sized gravel at 6 cudm per sqm. 1112 22.13 Supplying and applying bituminous solution primer on roof and or wall surface at 0.24 litre per sqm. 1113 22.14 Grading roof for receiving water proofing treatment with 22.14.1 Cement concrete 1:2:4 (1 cement : 2 sand : 4 graded stone aggregate 20 mm nominal size) 22.14.2 Cement mortar 1:3 (1 cement : 3 sand) 22.14.3 Cement mortar 1:4 (1cement : 4 sand) 1114 22.15 Providing and laying insitu six course water proofing treatment with APP (Atactic poly- propylene) modified Polymeric membrane over roof consisting of first coat of bitumen primer @ 0.40Kg per sqm,conforming to IS : 702, 3rd and 5th layers of roofing membrane APP modified Polymeric membrane 1.5mm thick of 2.25 Kg/sqm weight consisting of five layers prefabricated with centre core as 20micron HMHDPE film sandwiched on both sides with polymeric mix and the polymeric mix is protected on both side with 20 micron HMHDPE film. (with 5 years service guarantee) 1115 22.16 Providing and laying in situ four course water proofing treatment with APP (Atactic Polypropylene) modified Polymeric membrane over roof consisting of first coat of bitumen primer @ 0.40Kg per sqm, conforming to IS : 702, 3rd layer of roofing membrane APP modified Polymeric membrane 2.0mm thick of 3.00 Kg/sqm weight consisting of five layers prefabricated with centre core as 100micron HMHDPE film sandwiched on both sides with polymeric mix and the polymeric mix is protected on both side with 20micron HMHDPE film. (with 5 years service guarantee). 1116 22.17 Providing and laying in situ six course water proofing treatment with APP (Atactic Polypropylene) modified Polymeric membrane over roof consisting of first coat of bitumen primer @ 0.40Kg per sqm, conforming to IS : 702, 3rd and 5th layers of roofing membrane APP modified Polymeric membrane 2.0mm thick of 3.00 Kg/sqm weight consisting of five layers prefabricated with centre core as 100 micron HMHDPE film sandwiched on both sides with polymeric mix and the polymeric mix is protected on both side with 20micron HMHDPE film. (with five years service gurantee). 1117 22.18 Providing and fixing APP (Atactic Polypropylene Polymer) modified prefabricated five layer 2mm thick water proofing membrane for corrugated roof sheets, black finished reinforced with glass fibre matt consisting in longitudinal and transverse direction at 23°C as 350/300 N/ 5cm. Tear strength in longitudinal and transverse direction as 60/80N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got done through the authorised applicator of the manufacture of membrane. (With five years service gurantee). 1118 22.19 Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer, 3mm thick water proofing membrane, black finished reinforced with glass fibre matt consisting of a coat of bitumen primer of the membrane shall be as under:Joint strength in longitudinal and transverse direction at 23°C as 350/300 N/5cm. Tear strength in longitudinal and transverse direction as 60/80N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane : (with 5 years service guarantee) 1119 22.20 Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer 3mm thick water proofing membrane, black finished reinforced with non-woven polyester matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 ltr/sqm. by the same membrane manufacture of density at 23°C as 650/450N/5cm. Tear strength in longitudinal and transverse direction as 300/250N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane: (with 5 years service guarantee). 1120 22.21 Extra for covering top of membrane with Geotextile, 120gsm non woven, 100% polyester of thickness 1 to 1.25mm bonded to the membrane with intermittent touch by heating the membrane by Butane Torch as per manufactures recommendation. [for item No. 22.18 to 22.20] 1121 22.22 Water proofing treatment over Roof, Wall, Chajjas,, Balcony with fibre glass mesh and Sealer coat at leakage/ seepage area consisting of (i)   Surface preparation roughening of surface, opening cracks in ‘V’ groove in size of 5mmX10mm (WXD), filling of cracks with putty with laying fiber glass mesh, Cleaning of surface by scrubbing with steel wire/Nylon brush. Removing all dust particles and washing with adequate water to clean completely. (ii)     Providing and applying 1st coat of fibre glass mesh (minimum thicknes 70-80 micron) and two component flexible waterproof and protective modified mortar, dry powder 80% chemical 20% acrylic resin having 30% solid contents) with mix proportion of part 1 and 2 with proper mixing with laying of fiber glass mesh (of weaving size of 10X10 yarn/inch duly coated with alkaline resistant polymer). Allow the coating to air cure for minimum 2 Hrs. After two hours of 1st coat applying 2nd coat (minimum thickness 100 micron) of fibre glass mesh of with mix proporation of part 1 and 2 with proper mixing. Allow the coating to air cure for minimum 2 hrs. Consumption of two component should be acrylic resin @17.90 kg for 10 sqm area or as per manufacture instructions. (After two coats of diamond shield, surface is to be cured properly minimum for 4 hrs. before application of third coat). (iii) Providing and applying 1st coat of sealer coat 50-60 micron (single component Hight build elastomeric, fixable pure acrylic waterproofing membrane having solid content of 65%) and allow it to air cure for 4Hrs. minimum. After two hours minimum of 1st coat applying 2nd and finals coat 120-140 micron of sealer coat and allow it to air cure for 4 Hrs mimimum. Consumption of Sealer coat should be @ 5.40 kg per 10 sqm area. (iv) The treated area should be cure with water for 48 hrs. by flooding the surface. (v) The final appearance of the coating will be milky white. All above operations to be done in order.(five years guarantee) 1122 22.23 Providing water proofing treatment over Roof, Wall, Chhajjas, Balcony with Rubberized elastomeric cold applied liquid waterproofing membrane blend of special resin and rubber with more than 1300% elongation (confirming ASTM-D2370-98), at leakage/seepage area consisting of the following operation. (i)Removal of damaged waterproofing treatment if any like bituminous membrane / plaster/ brick bat koba/screeding etc. (ii) Surface preparation: Roughening of surface by scrubbing with steel wire/ Nylon brush/ Removing all dust particles and washing with adequate water to clean completely, opening of cracks in V groove in size of 5mm x 10m (WxD), filling of cracks with elastomeric creak filler/PU sealent repair of potholes and holor making on roof surface by polymer mortar with adding SBR bonding agent. (iii) Providing and applying 1st coating of rubberized elastomeric liquid membrane as primer (ratio 1:2 1 part liquid membrane and 2 part water) by brush/ Roller/ Spray having minimum thickness of 70-80 micron. Allow the coating to set in natural air for minimum 2 hrs, then put reinforcement by laying 45gsm fibre glass mesh and applying 2nd coat of rubberized elastomeric liquid membrane (Ratio: 1 part membrane and 20% water) with minimum thickness 100-120 micron. Allow the coating to set in natural air for minimum 12 hrs. (iv) Providing and applying 3rd coat of rubberized elastomeric liquid membrane (Ratio: 1 part membrane and 10% water). Total DFT (Dry film thickness) thickness after 3rd coat must be 280-300 micron and consumption in three coats @ 6.5kg for 10sqm. (v) Providing and applying 4th and 5th coat of High quality waterproof membrane in white colour, single component special synthetic resin based flexible thixotropic white color coating with excellent UV resistance (SRI - 144) with more than 300% elongation (confirming ASTM D 412-98) in ratio: 1 part membrane and 10% water thickness of 200 micron DFT in two coats, with average consumption @ 5kg per 10 sqm. After application of fourth coat let it air dry for minimum 3 hrs before application of fifth coat. (vi) The treated area must be tested for water leakage/seepage by flooding with water for 48 hrs (vii) Application of membrane coating shall be got done by authorized applicator of manufacturer. (viii) 5 years of service guarantee to be provided.All above operations to be done in order as per direction on Engineer-in-Charge. 1123 22.24 Supplying and applying fibre reinforced, UV resistant elastomeric liquid applied waterproofing & Heat reflective coating coating with PU Hybrid polymers & acrylic fibers. The coating shall resist 10 bars of water pressure as per DIN 1048 standards, with elongation of 350% as per ASTM D412 & crack bridging of upto 2.5mm conforming to ASNZ standard. The operation shall be carried out after scrapping and properly cleaning the surface to remove loose particles with wire brushes, complete in all respect as recommended by the manufacturer’s specification and as per the direction of Engineer-in-Charge. 1124 22.25 Supplying and applying two component elastomeric acrylic polymer modified cementitious waterproofing coating, having 80% elongation as per ASTM D412, resisting 5 bars hyrostatic pressure as per DIN 1048, reduction to rapid chloride shall be 70 as per DIN 1048, crack bridging upto 1.2mm as per ASTM 4548.5. The coating shall have food grade certificate from laboratories like CFTRI. The mixing ratio of the coating shall be 2 parts of powder & 1 part of liquid without any water addition in the mixing, etc., complete as per manufacturers specifications and as per direction of Engineer-in-Charge. 1125 22.26 Providing and applying UV Stable polyurethane liquid water proofing membrane having Sun Reflectivity Index (SRI) of 106 on top of concrete roof / Retainning wall / Old layer of bituminous surfaces / Polyurethane foam and metal surfaces in three or more coats @20kg/ 10 sqm consisting of a coat of two component epoxy primer in ratio of 1:3(one part of resin and 3 parts of hardner) at a consumption of 2kg/10sqm. the vital physical and chemical parameters shall be as under : Min Elongation at break of 600% as per ASTM D412 and tensile strength of 3.0 N/mm2 as per ASTM D412. The operation shall be carried out after scrapping and properly cleaning the surface to remove loose particles with wire brushes, complete in all respect as recommended by the manufacturer’s specification and direction of Engineer-in-Charge. 1126 22.27 Supplying & installing waterproofing treatment by using 1.2 mm thick HDPE membrane before casting of the base RCC slab. The pre-applied membrane gets bonded to the underneath of the poured concrete used as base slab. The membrane shall consist of a thick HDPE film, a highly aggressive pressure sensitive adhesive and weather resisting coating which bonds integrally to poured concrete of base slab. The membrane shall conforms to basement waterproofing protection to grades 2, 3 & 4 as defined in BS 8102:2009. The waterproofing membrane shall have following minimum properties: a)    Resist hydrostatic pressure of up to 70 m head of water as per ASTM D5385; b)      Puncture Resistance of 950 N (as per ASTM E154) c)      Elongation of >400 % (as per ASTM D412) d)    Peel Strength of concrete: >1500 N/m (as per ASTM D903) e)      Tensile strength of 28.2 MPA (as per ASTM D412). 1127 22.28 Providing and applying 2.0 mm thick twin colour flexible PVC waterproofing membrane. Flexibility under low temperatures as per EN 495-5 should be < - 20degC. On all horizontal surfaces Geotextile 300 Gsm to be laid over PCC, than laying PVC membrane over Geotextile and to be sealed with hot air welding method at all joints and over PVC membrane provide 300 Gsm Geotextile Then protection screed of suitable thickness. On all vertical surfaces Geotextile 300 Gsm to be laid along with Vertical wall, than laying PVC membrane over Geotextile and to be sealed with hot air welding method at all joints and over PVC membrane providing protection layer of Drain Board HDPE Dimple sheet before back filling of soil. 1128 22.29 Providing and applying waterproofing & Heat reflecting roof coating with 100% acrylic elastomeric polymers. Contains 30% Volume solid, tensile strength 8 kg/cm², crack bridging, VOC 30 ± 5 gm/ltr upto 2 mm. then applying two coats with forced coverage of 20 sqft/ltr/two coats. The operation shall be carried out after scrapping & propely clening the surface to remove loose particles with wire brush/Jet washer. Apply 1 coat @1 ltr/10 sqm & 3 undiluted coats @ 8 ltr/10 sqm with 4 hrs interval of each coat.The work shall be carried out as recommended by the manufacturer’s specification & the direction of the Engineer- in-Charge. 1129 22.30 Providing & applying crack fill paste for crack filling up to 5 mm cracks.Widen the crack by putty knife in V/U shape & apply 1st priming coat of crack fill paste diluted with water in 1:1 proportion over the crack by brush. Apply 2nd coat with filling of crack fill paste when the surface is tacky but not dried completely with putty knife & spatula.After 4 hours of application 2nd coat apply 3rd coat of Crack fill paste. The work shall be carried out as recommended by the manufacturer’s specification & the direction of the Engineer-in-Charge 1130 22.31 Providing & applying single pack component, solvent-free, cold applied, Polyurethane modified, elastomeric liquid applied waterproofing membrane- PU coat with excellent UV resistant capacity, The material shall meet the requirement as specified in ASTM D2370-98 of elongation at break of film>350% with geotextile fleece =50% approx.The work shall be carried out as recommended by the manufacturer’s specification & the direction of the Engineer- in-Charge. The product performance shall carry guaranteed for 5 year against any leakage. 22.31.1 For Horizontal surface (with Geotextile fleece) two coats without dilution & 1 Self priming coat- 50% dilution with water @ 10 kg/m2 22.31.2 For Horizontal surface (without Geotextile fleece) two coats without dilution & 1 Self priming coat- 50% dilution with water @ 10 kg/m2 1131 22.32 Providing and mixing integral crystalline admixture for water proofing treatment to RCC structures like basement raft, retaining walls, reservior, sewage & water treatment plant, tunnels / subway and Compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure. The crystalline admixture shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the Engineer-in-Charge. The product performance shall carry guarantee for 10 years against any leakage. 1132 22.33 Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc. The material shall meet the requirements as specified in ACI- 212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on positive side. The crystalline slurry shall be capable of self- healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage. 22.33.1 For vertical surface two coats @ 0.70 kg per sqm 22.33.2 For horizontal surface one coat @1.10 kg per sqm. 1133 22.34 Providing and applying integral crystalline (dry shake) of hydrophilic in nature for waterproofing treatment to the RCC structures like basement raft, foundation slab, sewage & water treatment plant slab, warehouses floor, parking structures and water tank base slab etc. crystalline dryshake shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the Engineer-in-charge. The product Performance shall carry guarantee for 10 years against any leakage. 1134 22.35 Providing and applying crystalline mortar by mixing in the ratio of 4.5 : 1 (4.5 parts crystalline mortar : 1 part water) for the treatment of faulty construction joints, cracks, tie rod holes and spalled & honeycombed surface of RCC underground structures like basement, water tanks, bridge deck etc. to ensure water tightness. The crystallie mortar shall conform to the EN 1504-3 having compressive strength Class R4 > 45 MPa and adhesive bond strength Class R3 > 1.5 MPa. The work shall be carried out all complete as per specification and the direction of the Engineer-In-Charge.The product performance shall carry guarantee for 10 years against any leakage. 22.35.1 For sealing cracks and faulty construction joints, routed out/making U-shape groove size 25x25mm and then primed the area with integral crystalline slurry @0.05kg/ running metre and while the surface is tacky filled the groove upto surface with crystalline mortar @1.50kg/ running metre. Once crystalline mortar is touch dry then finally applied two coats of integral crystalline slurry @0.05kg/running metre per coat. 22.35.2 For patching of tie rod holes, prepared tie rod hole surface and then primed the area with integral crystalline slurry @ 0.070 kg/sqm and while the surface is tacky repair and then filled the tie rod holes with crystalline mortar @ 0.040 kg per hole. The crystalline mortar should be tightly rodded into tie rod holes or packed tightly (For 25x25x25 mm tie rod hole, use 0.040 kg to fill the hole) 1135 22.36 Providing and applying of swellable type water stop tape, 19mm x 25mm thick in linear meter (expansive nature) for construction joints treatment of RCC structure such as raft slab, retaining walls, water storage tank and at the junctions of raft slab with the retaining walls etc. After cleaning the surface, one coat of required primer for swellable water stop tape shall be applied throughout the length of the joint @3.78 litre per 240 running meter. Over the primed surface swellable type water stop tape shall be placed. The work shall be carried out all complete as per specification and the direction of the Engineer-In-Charge. The product performance shall carry guarantee for 10 years against any leakage. 1136 22.37 Providing and applying waterproofing treatment in bathroom or tiled balcony area without breaking or removing tiles, by using waterproofing sheets as per manufacturers data sheet instructions. Permitting use of bathroom/balcony after 24 hours of application of treatement, Complete with materials and labour and gurantee of leakage for a period of 5 year. 1137 23.11 Providing and fixing 2 mm thick homogeneous conductive PVC (Poly Vinyl Flooring) EN (European Standard), total weight is 3250 g/m2, approx. PUR (Polyurethane Reinforced ), abrasion group P: ≤2.00 mm, residual indentation approx. 0.03 mm, anti-bacterial and fungal resistance, castor wheel test qualified, dimensional Phthalate free, directional in design.The floor finish should be termite free at the room perimeter passing over a concealed cove forming and continuing up on the wall upto 100mm.Recommended to use in area like ICU , Post operative, Recovery rooms, OPD, Patient rooms, Corridors ,passages etc. 1138 23.12 Providing and fixing permanently static dissipative pressed homogeneous conductive PVC ( Poly Vinyl Flooring) EN (European Standard), anti static, wear layer thickness is 2mm (EN429), vinyl flooring having carbon backing with total weight 3000 g/m2 ESD approved, restorable properties, available in rolls. 100% recyclable (eco - freindly). Low VOC emission after 28days of installation (lower than ≤100μg/m3), Phthalate free non-directional in Design. Recommended to use in area like Operation theater, ICU, Server room, etc. 1139 23.13 Providing and fixing 0.92mm thick hetrogeneous compact PVC (Poly Vinyl Wall Covering) for Interior wall area, with wear layer thickness 0.12mm of PVC, EN(European Standard) total weight is 1500 g/m2, approx PUR (Polyurethane Reinforced), good resistance to chemical and fire, doesn’t favour in growth of fungi and bacterial, 100% recyclable (eco-freindly), low VOC emissions after 28 days of installation (lower than ≤10μg/m3), phthalate free, directional in design, The wall finish should termite free at the room perimeter. Recommended to use in area like OT,ICU, Corridors, Patient Room etc. 1140 23.14 Providing and fixing 1.3mm thick homogeneous PVC (Poly Vinyl Wall Covering) for interior area with wear layer thickness 1.3 mm of PVC, EN (European Standard) total weight is 2100 g/m2,approx. PUR (Polyurethane Reinforced), good resistant to chemical and fire, doesn’t favour in growth of fungi and bacterial, 100% recyclable (eco-freindly), low VOC emissions after 28days of installation (lower than ≤10μg/m3), phthalate free, directional in design.The wall finish should termite free at the room. Recommended to use in area like OT.ICU,Corridors, Passages , Patient Room Etc 1141 23.15 Supply and installation of 2mm thick homogeneous vinyl flooring, Highest abrasion wear rating Group T (EN660), binder content exceeds 55% of the flooring composition, no waste technology, consisting of PVC resin, plasticizers and stabilizers, type I. flooring ( (EN ISO 23997) max 0.4%, Abrasion group (MSZ EN 660-1) T, Fire resistance EN 13501-1 BF1-s1, Slip resistance DIN 51130 R9, EN 13893 DS, electrical resistance EN 1815 <2 kv, Chemical resistance EN ISO 26987, Castor chair resistance EN ISO 4918, Hygenie Bacterial resistant, Seaming method - hot welding, finishing complete . Recommended to use in area like Operation theater, ICU, Server room, etc. 1142 24.8 Supplying and installation of moisture resistant/fire resistant 6 mm thick Heavy duty fiber cement board (High pressure steam cured) conforming to IS 14862:2000 of category III type B as per standard sizes fixed with self- drilling / taping screws. Screws shall be of counter sunk rib head of 1.60mm to 4 mm thick of 8 to 10 gauge of length varying from 25 to 45 mm. 1143 24.9 Providing and fixing thermal insulation with Resin Bonded glass wool conforming to IS: 8183, having density 48 kg/m3. 50 mm thick, wrapped in 200 G Virgin Polythene Bags fixed to wall with screw, rawl plug and washers and held and in position by crisscrossing GI wire etc. complete as per directions of Engineer-in-Charge. 24.9.1 Providing and fixing insulation with resin bonded Glass wool 24.9.2 Providing and fixing insulation with resin bonded Rock wool 1144 24.11 Providing and fixing precoatedgalvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-Charge) 0.50 mm + 0.05 %, total coated thickness with zinc coating 120 gsmlength upto 12 metre or as desired by Engineer-in- charge. The sheet shall be fixed using self-drilling /self-tapping screws of size (5.5x 55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 1145 24.12 Providing and fixing precoatedgalvanised steel sheet roofing accessories 0.50 mm + 0.05 % total coated thickness, Zinc coating 120gsm as per IS: 277 in 240 mpa steel grade, 5- 7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self-drilling/ self-tapping screws complete : 24.12.1 Ridges plain (500 - 600mm). 24.12.2 Flashings/ Aprons.( Upto 600 mm) 24.12.3 North light curves. 24.12.4 Barge board (Upto 300 mm). 24.12.5 Crimp curve 24.12.6 Gutter. (600 mm over all girth). 1146 25.1 Providing and fixing white vitreous china Anti germ Fluoro-Polymer Coated Water closet squatting pan with 100 mm sand cast Iron P and S- trap, and 7.2 liter Low level, dual flush, PP (Poly Propylene) made open slim wall hung cistern capacity 3 liter/6 liter flushing, with all fittings and fixtures complete including cutting and making good the wall and floors wherever required. 25.1.1 White Vitreous china Anti germ Fluoro-Polymer coated Orissa Pattern W. C. Pan of Size 440x575x250 mm With integral foot rests. (Premium Range) 25.1.2 White Vitreous china Anti germ Fluoro-Polymer coated Orissa pattern W. C. pan of size 410x515x255 mm with integral foot rests. (Premium Range) 1147 25.2 Providing and fixing white vitreous china pedestal type Anti germ Fluoro-Polymer Coated Water Closet with soft closing seat cover, and 7.2 litre Low level slim dual flushing, PP (Poly Propeline) made 80 mm thick concealed flushing cistern, flushing capacity 3 litre/6 litre, with all fittings and fixtures complete including cutting and making good the wall and floors wherever required. 25.2.1 Anti-germ Fluoro-Polymer Coated (nano coating) European W. C. pan size 360x545x395 mm with solid poly propelyne made soft closing seat cover (Premium Range) 25.2.2 Anti-germ Fluoro-Polymer Coated Water Closet European type W. C. pan size 360x545x395 mm with solid poly propelyne made soft closing seat cover (Premium Range) 1148 25.3 Providing and fixing white vitreous china European Wall hung Anti germ Fluoro-Polymer Coated water closet of approved shape with soft closing seat cover, and 7.2 litre Low level slim dual flushing, PP (Poly Propylene) made 80 mm thick concealed flushing cistern, flushing capacity 3 litre/6 litre, with all fittings and fixtures complete including cutting and making good the wall and floors wherever required. 25.3.1 Anti germ Fluoro-Polymer Coated (Nano coating) Wall hung water closet Size 380x520x375 mm with solid poly propelyne made soft closing seat cover (Premium Range) 25.3.2 Anti germ Fluoro-Polymer Coated (Nano coating) Wall hung water closet size 390x570x365 mm with solid poly propelyne made, soft closing seat cover (Premium Range) 25.3.3 Anti germ Fluoro-Polymer Coated (Nano coating) Wall hung water closet size 360 x 500x360 mm with solid poly propelyne made, soft closing seat cover (Premium Range) 25.3.4 Anti germ Fluoro-Polymer Coated (Nano coating) Wall hung water closet size 360x500x330 mm or greater size with solid poly propelyne made, soft closing seat cover (Premium Range) 1149 25.4 Providing and fixing white vitreous china Anti germ fluoro-polymer coated couple water closet flushing capacity 3 and 6 litre of approved shape with 15mm quarter turn angular stop cock and pvc connection pipe i/c cutting and making good the wall and floors wherever required with all fittings and fixtures etc. complete . 25.4.1 Anti germ Fluoro-Polymer Coated couple water closet Size 420x710x810 mm with solid poly propelyne made soft closing seat cover. (Premium Range) 25.4.2 Anti germ Fluoro-Polymer Coated couple water closet Size 380x610x805 mm with solid poly propelyne made soft closing seat cover. (Premium Range) 25.4.3 Anti germ Fluoro-Polymer Coated couple water closet Size 370 x 640 x 760mm with solid poly propelyne made soft closing seat cover. (Premium Range) 25.4.4 Anti germ Fluoro-Polymer Coated couple water closet Size 375 x 650 x 800 mm with solid poly propelyne made soft closing seat cover. (Premium Range) 1150 25.5 Providing and fixing white vitreous china Anti germ fluoro-polymer coated single piece W.C. dual flushing capacity 3 and 6 litre of approved shape with 15mm quarter turn angular stop cock and pvc connection pipe i/c cutting and making good the wall and floors wherever required all fittings and fixtures etc. complete. 25.5.1 Anti germ Fluoro-Polymer Coated Single Piece W.C. Pan Size 370x695x795 mm with solid poly propelyne made soft closing seat cover.(Premium Range) 25.5.2 Anti germ Fluoro-Polymer Coated Single Piece W.C. Pan Size 395x710x730 mm with solid poly propelyne made soft closing seat cover.(Premium Range) 25.5.3 Anti germ Fluoro-Polymer Coated Single Piece W.C. Pan Size 385 x 720 x 710mm with solid poly propelyne made soft closing seat cover.(Premium Range) 25.5.4 Anti germ Fluoro-Polymer Coated Single Piece W.C. Pan Size 360 x 640 x 685 mm with solid poly propelyne made soft closing seat cover.(Premium Range) 1151 25.6 Providing and fixing white vitreous china made Anti germ fluoro-polymer coated extended wall hung type couple closet along with dual flushing cistern flushing capacity 3 & 6 litre approved shape with 15mm quarter turn angular stop cock and pvc connection pipe i/c cutting and making good the wall and floors wherever required all fittings and fixtures etc. complete. 25.6.1 Anti germ Fluoro-Polymer Coated extended wall hung type couple closet Size 760X360X635mm with solid poly propelyne made soft closing seat cover (Premium Range) 25.6.2 Providing and fixing white vitreous china made Anti germ fluoro-polymer coated extended wall hung type couple closet Size 380x650x730 mm along with dual flushing cistern flushing capacity 3 & 6 litre. (Premium Range) 1152 25.7 Providing and fixing white vitreous china type Anti germ Fluoro-Polymer Coated Wash Basin with C.I. Brackets, 15 mm C. P. wall mounted pressmatic pillar cock auto closing system (decol technology), 15mm quarter turn angular stop cock, 32 mm C.P. brass made waste coupling length 130mm and 32 mm C.P. Brass Made Bottle Trap size 200x300mm fittings and fixtures complete including Painting of fittings and cutting and making good the wall and floors wherever required. 25.7.1 White Vetrious China Anti germ Fluoro-Polymer Coated Wash Basin Size 595x435x185 mm with basin mounted pressmatic pillar cock auto closing system (decol technology). (Premium Range) 1153 25.8 Providing and fixing white vitreous china type Anti germ fluoro-polymer coated counter top wash basin with 15 mm C. P. wall mounted pressmatic Pillar cock auto closing system (decol technology), 32 mm C.P. brass waste coupling length 130mm and 32 mm C.P. brass bottle trap size 200x300mm i/c cutting and making good the wall and floors wherever required all fittings and fixtures etc. complete. 25.8.1 White Vetrious China Anti germ Fluoro-Polymer Coated Wash Basin Size 570x820x195 mm with wall mounted pressmatic pillar cock auto closing system (decol technology). (Premium Range) 25.8.2 Providing and fixing white vitreous china type Anti germ fluoro-polymer coated counter top wash basin Size 570x820x195 mm with 15 mm C. P. wall mounted pressmatic Pillar cock auto closing system (decol technology). (Premium Range) 1154 25.9 Providing and fixing white vitreous china type Anti germ fluoro-polymer coated counter top wash basin with 15 mm C. P. wall mounted single lever concealed basin mixture, (cartridge size 32 mm) 32 mm C. P. brass waste coupling length 130mm and 32 mm C. P. brass bottle trap size 200x300mm i/c cutting and making good the wall and floors wherever required, all fittings and fixtures etc. complete. (Premium Range) 25.9.1 White Vetrious China Anti germ Fluoro-Polymer Coated Wash Basin Size 615x415x150mm with wall mounted single lever concealed basin mixture (cartridge size 32mm.) (Premium Range) 25.9.2 Providing and fixing white vitreous china type Anti germ fluoro-polymer coated counter top wash basin Size 600x400x185 mm with 15 mm C. P. wall mounted single lever concealed basin mixture. (Premium Range) 1155 25.10 Providing and fixing white vitreous china type Anti germ Fluoro-Polymer Coated Wash Basin with 15 mm Table mounted single lever Tall boy basin mixture, (cartridge size 32 mm) 15mm quarter turn angular stop cock, 32 mm C. P. brass made waste coupling length 130mm and 32 mm C.P. Brass Made Bottle Trap size 200x300mm fittings and fixtures complete including Painting of fittings and cutting and making good the wall and floors wherever required. 25.10.1 White Vetrious China Anti germ Fluoro-Polymer Coated Wash Basin Size 595x435x185 mm with Table mounted single lever Tall boy basin mixture, (cartridge size 32mm.) (Premium Range) 25.10.2 White vitreous china type Anti germ fluoro- polymer coated counter top wash basin Size 530x420x140 mm with tall boy basin mixture, (cartridge size 32 mm). (Premium Range) 1156 25.11 Providing and fixing white vitreous china flat back Anti germ fluoro-polymer coated urinal (Inbuilt spreaders, bottle trap and ceramic waste coupling) with 15mm brass pressmatic auto closing concealed urinal flush valve with wall flange (decol technology, 400000 operation warranted) i/c cutting and making good the wall and floors wherever required, all fittings and fixtures etc. complete . 25.11.1 White Vitreous China Anti germ Fluoro-Polymer Coated Urinal Size 340x325x650 mm. (Premium Range) 25.11.2 White Vitreous China Anti germ Fluoro-Polymer Coated Urinal Size 475x315x715 mm. (Premium Range) 25.11.3 White Vitreous China Anti germ Fluoro-Polymer Coated Urinal Size 385x325x635 mm. (Premium Range) 1157 25.12 Providing and fixing white vitreous china Flat Back Anti germ Fluoro-Polymer Coated urinal (Inbuilt spreaders, Inbuilt Bottle trap and inbuilt ceramic Waste coupling)with sensotronic concealed type flushing valve for urinal complete set with installation box with control cock complete including painting of fittings and brackets, cutting and making good the wall and floors wherever required . 25.12.1 White Vetrious China Anti germ Fluoro-Polymer Coated Urinal Size 340x325x650 mm with sensotronic concealed type flushing valve for urinal complete set with installation box with control cock. (Premium Range) 25.12.2 White Vetrious China Anti germ Fluoro-Polymer Coated Urinal size 385x325x635 mm with concealed sensotronic flushing valve for urinal complete set with installation box, (Premium Range) 1158 25.13 Providing and fixing white vitreous china Flat Back Anti germ Fluoro-Polymer Coated Urinal (Inbuilt spreaders, Inbuilt Bottle trap and inbuilt ceramic Waste coupling) with 15mm Brass made pressmatic (Decol technology, 400000 operation warranted) concealed flushing Stop cock complete including painting of fittings and brackets, cutting and making good the wall and floors wherever required . 25.13.1 White Vetrious China Anti germ Fluoro-Polymer Coated Urinal Size 480x300x740 mm with 15mm Brass made pressmatic auto closing concealed urinal flush valve with wall flange (Decol technology, 400000 operation warranted). (Premium Range) 1159 25.14 Providing and fixing white vitreous china Flat Back Anti germ Fluoro-Polymer Coated Urinal (Inbuilt spreaders, Inbuilt Bottle trap and inbuilt ceramic Waste coupling)with sensor complete including painting of fittings and brackets, cutting and making good the wall and floors wherever required. 25.14.1 White Vetrious China made Flat Back Anti germ Fluoro-Polymer Coated Urinal (Inbuilt spreaders, Inbuilt Bottle trap and inbuilt ceramic Waste coupling) Size 340x325x650 mm with sensor (Premium Range) 25.14.2 Providing and fixing white vitreous china flat back Anti germ fluoro-polymer coated Urinal size 7475x315x715 mm (Inbuilt spreaders, bottle trap and ceramic waste coupling) with inbuilt sensor for flushing. (Premium Range) 1160 25.15 Providing & Fixing 8mm thick froasted Urinal glass partition size 900x450mm brass made bracket with chrome plating. (Premium Range) 1161 25.16 Providing & Fixing 8mm thick froasted Urinal glass partition size height 900 mm top width 450mm and bottom width 300mm brass made bracket with chrome plating. (Premium Range) 1162 25.17 Providing & Fixing plain bath tub of size 180x80x47cm body made of PMMA (Poly Methyl metha acrylate) with 20mm wooden reinforcement. (Premium Range) 1163 25.18 Providing and fixing in position best Indian ( bonut size 24mm, ceramic disc size 19mm and min. body thickness 2mm, nickel plating 0.10 micron and chrome plating 0.3 micron, quarter turn) Pillar cock. (Premium Range) 1164 25.19 Providing and fixing in position best Indian ( bonut size 24mm, ceramic disc size 19mm and min. body thickness 2mm, nickel plating 0.10 micron and chrome plating 0.3 micron, quarter turn)Bib cock. (Premium Range) 1165 25.20 Providing and fixing in position best Indian ( bonut size 24mm, ceramic disc size 19mm and min. body thickness 2mm, nickel plating. 10 micron and chrome plating 0.3 micron, quarter turn) Angular stop cock. (Premium Range) 1166 25.21 Providing and fixing in position best Indian (bonut size 24mm, ceramic disc size 19mm and min. body thickness 2mm, nickel plating 0.10 micron and chrome plating 0.3 micron, quarter turn) Concealed stop cock. (Premium Range) 1167 25.22 Providing and fixing in position best Indian ( bonut size 24mm, ceramic disc size 19mm and min. nickel plating 0.10 micron and chrome plating 0.3 micron, quarter turn) Wall Mixer with 115mm bend. (Premium Range) 1168 25.23 Providing and fixing in position best Indian ( bonut size 24mm, ceramic disc size 19mm, nickel plating 0.10 micron and chrome plating 0.3 micron, quarter turn) 3-in1 Wall Mixer .(Premium Range Sanitary Ware) 1169 25.24 Providing and fixing in position best Indian C. P. brass made quarter turn (Ceramic disc Size 25mm) Flush Cock for Indian W. C. (Orissa Pan). (Premium Range) 1170 25.25 Providing and fixing in position best Indian single Lever Auto Mixing Wall Mixer (Cartridge Size 40mm, nickel plating 0.10 micron and chrome plating 0.3 micron) for Shower area use only. (Premium Range) 1171 25.26 Providing and fixing in position best Indian single Lever Auto mixing Basin Mixer (Cartridge Size 32mm, nickel plating 0.10 micron and chrome plating 0.3 micron) For Wash Basin area use only. (Premium Range) 1172 25.27 Providing and fixing in position best Indian single Lever Auto Mixing Diverter (Cartridge Size 47mm, nickel plating 0.10 micron and chrome plating 0.3 micron) for Shower area use only. (Premium Range) 1173 25.28 Providing and fixing in position best Indian C. P. brass made Spout (nickel plating 0.10 micron and chrome plating 0.3 micron). (Premium Range) 1174 25.29 Providing and fixing in position best Indian C. P. brass made Shower Arm Length 300mm (nickel plating 0.10 micron and chrome plating 0.3 micron). (Premium Range) 1175 25.30 Providing and fixing in position best Indian C. P. brass made Shower Arm Length 450mm (nickel plating 0.10 micron and chrome plating 0.3 micron).(Premium Range Sanitary Ware) 1176 25.31 Providing and fixing in position best Indian C. P. brass made Shower Arm Length 600mm (nickel plating 0.10 micron and chrome plating 0.3 micron) .(Premium Range Sanitary Ware) 1177 25.32 Providing and fixing in position best Indian shower rose 300x300mm square body and face chrome plated, brass made body, Silicon based Rubbit cleaning nozzles.(Premium Range Sanitary Ware) 1178 25.33 Providing and fixing in position best Indian shower rose 150mm dia, body and face chrome plated, brass made body, Silicon based Rubbit cleaning nozzles.(Premium Range) 1179 25.34 Providing and fixing in position best Indian shower rose 200mm dia body and face chrome plated, brass made body, Silicon based Rubbit cleaning nozzles .(Premium Range) 1180 25.35 Providing and fixing in position best Indian shower rose 240mm body and face chrome plated, brass made body, Silicon based Rubbit cleaning nozzles.(Premium Range) 1181 25.36 Providing and fixing in position best Indian (bonut size 24mm, ceramic disc size 19mm and min. body thickness 2mm, nickel plating 0.10 micron and chrome plating 0.3 micron, quarter turn) 2- way Bib Cock .(Premium Range) 1182 25.37 Providing and fixing in position best Indian Health Faucet with 8mm dia 1.20 meter long Flexible Tube and wall bracket with N. R. V. (non-return wall).(Premium Range Sanitary Ware) 1183 25.38 Providing and fixing in position best Indian Auto Closing Pillar Cockdody with 65 mm extension (with DECOL cartridge) for wash basin use. (Premium Range) 1184 25.39 Providing and fixing in position best Indian Auto Closing Bib Cock with built in control cock wihh wall flange (with DECOL cartridge) for common area use. (Premium Range) 1185 25.40 Providing and fixing in position best Indian Auto Closing Urinal valve open type with built in control cock wihh wall flange (with DECOL cartridge) for urinal use only. (Premium Range) 1186 25.41 Providing and fixing in position best Indian Auto Closing Urinal valve concealed type (with DECOL cartridge) for urinal use only. (Premium Range) 1187 25.42 Providing and fixing in position best Indian Auto Closing wall mounted Pillar Cock (with DECOL cartridge) for wash basin use only. (Premium Range) 1188 25.43 Providing and fixing in position best Indian Auto Closing 40mm Flush valve (for W. C. European and Wall Hung Type) concealed type (with DECOL technology/ cartridge). (Premium Range) 1189 25.44 Providing and fixing in position best Indian Auto Closing 40mm Dual Flow (3.0/6.0 liter) Flush valve (for W. C. European and Wall Hung Type) concealed type (with DECOL technology/ cartridge). (Premium Range) 1190 25.45 Providing and fixing in position best Indian Auto Closing 32mm, Flush valve (for W. C. European and Wall Hung Type) concealed type (with DECOL technology/cartridge). (Premium Range) 1191 25.46 Providing and fixing in position best Indian Sensotronic Sensor Faucet for Wash Basin use only. (Premium Range) 1192 25.47 Providing and fixing in position best Indian Sensotronic Sensor battery & electrical oprated type (9V transformer) Faucet For Urinal use only. (Premium Range) 1193 25.48 Providing and fixing in position best Indian Sensotronic Sensor concealed type Faucet For Wall Mounted Water Closet use only. (Premium Range) 1194 25.49 Providing and fixing in position best Indian C. P. Brass made (0.3 micron Chrome and 10 micron Nickel plated) Single Towel Rail 300 mm long. (Premium Range) 1195 25.50 Providing and fixing in position best Indian C. P. Brass made (0.3 micron Chrome and 10 micron Nickel plated) Single Towel Rail 600 mm long. (Premium Range) 1196 25.51 Providing and fixing in position best Indian C. P. Brass made (0.3 micron Chrome and 10 micron Nickel plated) Swivel Towel holder Twin Type. (Premium Range) 1197 25.52 Providing and fixing in position best Indian C. P. Brass made (0.3 micron Chrome and 10 micron Nickel plated) Single Towel Ring Square. (Premium Range) 1198 25.53 Providing and fixing in position best Indian C. P. Brass made (0.3 micron Chrome and 10 micron Nickel plated) Soap Dish Holder. (Premium Range) 1199 25.54 Providing and fixing in position best Indian C. P. Brass made (0.3 micron Chrome and 10 micron Nickel plated) Soap Dispenser with Metallic Bottle. (Premium Range) 1200 25.55 Providing and fixing in position best Indian C. P. Brass made (0.3 micron Chrome and 10 micron Nickel plated) Tumbler Holder. (Premium Range) 1201 25.56 Providing and fixing in position best Indian C. P. Brass made (0.3 micron Chrome and 10 micron Nickel plated) Toilet paper holder with Flap. (Premium Range) 1202 25.57 Providing and fixing in position best Indian C. P. Brass made (0.3 micron Chrome and 10 micron Nickel plated) Toilet Roll Holder. (Premium Range) 1203 25.58 Providing and fixing in position best Indian C. P. Brass made (0.3 micron Chrome and 10 micron Nickel plated) Glass Self-size 600mm with toughened glass (Premium Range) 1204 25.59 Providing and fixing in position best Indian C. P. Brass made (0.3 micron Chrome and 10 micron Nickel plated) Double coat Hook. (Premium Range) 1205 25.60 Providing and fixing in position best Indian C. P. Brass made (0.3 micron Chrome and 10 micron Nickel plated) Towel Rake 600 mm. (Premium Range) 1206 25.61 Providing and fixing in position best Indian C. P. Brass made (0.3 micron Chrome and 10 micron Nickel plated) W. C. Brush Holder. (Premium Range) 1207 25.62 Providing & Fixing 8mm thick froasted Urinal glass partition size 900x450mm brass made bracket with. (Premium Range) 1208 25.63 Wall Hung Basin: Providing and fixing white vitreous china type Anti germ fluoro-polymer coated wall mounted wash basin with C.I. brackets, C. P. brass single lever basin mixer, 15mm quarter turn angular stop cock, 32 mm C.P. brass waste coupling length 130mm and 32 mm C.P. brass bottle trap size 200x300mm i/c cutting and making good the wall and floors wherever required, all fittings and fixtures etc. complete . (Premium Range) 25.63.1 white Vetrious china Anti germ fluoro-polymer coated wall mounted wash basin size 620x480x185 mm. (Premium Range) 25.63.2 white Vetrious china Anti germ fluoro-polymer coated wall mounted wash basin size 570x470x190 mm. (Premium Range) 25.63.3 white Vetrious china Anti germ fluoro-polymer coated wall hung intergrated wash basin size 495x400x365 mm. (Premium Range) 25.63.4 white Vetrious china Anti germ fluoro-polymer coated wall hung intergrated wash basin size 500x440x385 mm. (Premium Range) 25.63.5 white Vetrious china Anti germ fluoro-polymer coated wall hung intergrated wash basin size 635x485x305 mm. (Premium Range) 1209 25.64 Wall Hung Basin ; Providing and fixing white vitreous china type Anti germ fluoro-polymer coated wall mounted wash basin with C.I. brackets, 15 mm C. P. brass pillar cock, 15mm quarter turn angular stop cock, 32 mm C.P. brass waste coupling length 130mm and 32 mm C.P. brass bottle trap size 200x300mm i/c cutting and making good the wall and floors wherever required, all fittings and fixtures etc. complete . (Premium Range) 25.64.1 white Vetrious china Anti germ fluoro-polymer coated wall mounted wash basin size 635x430x190 mm. (Premium Range) 1210 25.65 Providing and fixing in position best Indian, quarter turn table mounted sink mixer (bonut size 24mm, ceramic disc size 19mm and min. nickel plating 0.10 micron and chrome plating 0.3 micron). (Premium Range) 1211 25.66 Providing and fixing in position best Indian, quarter turn wall mounted sink cock (bonut size 24mm, ceramic disc size 19mm and min. nickel plating 0.10 micron and chrome plating 0.3 micron). (Premium Range) 1212 25.67 Shower Glass Cubical: Providing and fixing toughen glass shower enclosure conformed Is 2553 (part 1. 1990) or IS 14900. 2000 or IS 2835.1987 or IS 14450. 2000 with C. P. brass 5 Year warranted hardware, 19mm dia SS 304 grade stabilizer, all plastic Parts of food grade plastic and all glass shall be toughened at 700 degree Celsius and Anti lime scale treated including painting of fittings, cutting and making good the wall and floors wherever required, all fittings and fixtures etc. complete. (Premium Range) 25.67.1 Providing and fixing corner entry 6 mm toughen glass made to measurement shower enclosure size 1200mm x1200mm x 1950mm with aluminum profile on sides, shower enclosure with door sliding on both sides. (Premium Range) 25.67.2 Providing and fixing 8 mm toughen glass wall to wall sliding shower enclosure with one fixed glass and one silding door with a Towel Rod Fixed on the fixed glass size Hight:2000 mm Width: 1500mm to 2000mm. (Premium Range) 25.67.3 Providing and fixing 8 mm toughen glass made to measurement door Openable (inside/outside) shower enclosure two parts Wall to Wall enclosure with one fixed glass and openable door fixed withwall with square hardware & profile glass size Hight: 2000mm Width 800mm to 1200mm. (Premium Range) 1213 25.68 Providing and fixing 8 mm toughen glass made to measurement door Openable (inside/outside) shower enclosure two parts Wall to Wall enclosure with one fixed glass and openable door fixed with wall with square hardware & profile glass size Hight: 2000mm Width 800mm to 1200mm. (Premium Range) 1214 25.69 providing and fixing white tempered glass showerpenal with special Surface body materials tempered glass with glass special surface PVC back. ABS Movable tops Shower, 4 moveable ABS body massage jets, Hand shower with fiexible hose,Brass Sout, shelf, Thermostatic mixer with diverter, 40 cm stainless steel braided hose, Minimum water pressure required 2 bar. 1215 25.70 Thermostat Mixer : Providing and fixing in position best Indian, concealed high flow bath and shower mixer with thermostatic control cartridge (standard temperature range 15 degree c to 60 degree c, cartridge made of high performance thermostatic Polymer material with Anti scaled function). (Premium Range) 1216 25.71 Providing and fixing in position best Indian, exposed wall mounted bath and shower mixer with thermostatic control cartridge with button attachment on spout with connecting legs and wall flange ( standard temperature range 15 degree c to 60 degree c, cartridge made of high performance thermostatic Polymer material with Anti scaled function) .(Premium Range) 1217 25.72 Providing and fixing in position best indian, eko exposed shower mixer (wall mounted) with thermostatic control cartridge, 115mm long bend pipe on lower side, connecting legs and wall flange (standard temperature range 15 degree c to 60 degree c, cartridge made of high performance thermostatic Polymer material with Anti scaled function) . (Premium Range) 1218 25.73 Providing and fixing in position best Indian, exposed shower mixer (tub mounted) with thermostatic control cartridge, with button attachment on spout with straight legs (standard temperature range 15 degree c to 60 degree c, cartridge made of high performance thermostatic Polymer material with Anti scaled function). (Premium Range) 1219 25.74 Providing and fixing in position best Indian, 4 - way diverter consisting of concealed body and wall flange for multiple shower working with one shut-off position and 3 outlets for body shower, head shower and spout ( standard temperature range 15 degree c to 60 degree c, cartridge made of high performance thermostatic Polymer material with Anti scaled function). (Premium Range) 1220 25.75 Providing and fixing in position best Indian, thermostatic concealed high flow control valve with wall flange ( standard temperature range 15 degree c to 60 degree c, cartridge made of high performance thermostatic Polymer material with Anti scaled function) . (Premium Range) 1221 25.76 Medical Faucets : Providing and fixing in position best indian, single lever surgical purpose elbow action basin mounted mixer with extended Operating lever without popup waste system with 450mm long braided hoses (cartage size32mm, ceramic disc size 19mm and min. nickel plating 0.10 micron and chrome plating 0.3 micron, quarter turn). (Premium Range) 1222 25.77 Providing and fixing in position best Indian, surgical purpose elbow action pillar cock with extended Operating lever.( bonut size 24mm, ceramic disc size 19mm and min. nickel plating 0.10 micron and chrome plating 0.3 micron, quarter turn) (Premium Range) 1223 25.78 Providing and fixing in position best Indian, surgical purpose elbow action wall mounted pillar cock with extended Operating lever and wall flange. (bonut size 24mm, ceramic disc size 19mm and min. nickel plating 0.10 micron and chrome plating 0.3 micron, quarter turn). (Premium Range) 1224 25.79 Providing and fixing in position best Indian, 692mm long, satin finish C. P. Brass grab bar made of 304 grade ss i/c all nuts and screw (0.3 micron chrome and 10 micron nickel plated). (Premium Range) 1225 25.80 Providing and fixing in position best Indian, satin finish, C. P. Brass grab bar with left/right 90 degree angle, made of 304 grade ss i/c all nuts and screws. (0.3 micron chrome and 10 micron nickel plated). (Premium Range) 1226 25.81 Providing and fixing in position best Indian, C. P. Brass grab bar vertical swing, 304 grade ss made all nuts and screws. (0.3 micron chrome and 10 micron nickel plated). (Premium Range) 1227 25.82 Providing and fixing 8mm thick frosted safety glass Urinal partition size 900mm height and 450mm width, fixed with C P brass bracket of appropriate size i/c cutting and making good the wall and floors wherever required with all fittings and fixtures etc. complete.(Premium Range) 1228 27.4 Providing and fixing Stainless steel plate 304 grade of 1.50mm thick, including writing with Embossing of letters of required size including fixing at required placed with studs, screws and rawl plugs etc. compete as per direction of Engineer- in-Charge. 1229 27.5 Providing and fixing of name plate for offices name of Stainless steel plate 304 grade of 1.50mm thick, including writing with computerized vinayle sheet letters of required size including fixing at required placed with studs, screws and rawl plugs etc. compete as per direction of Engineer- in-Charge. 1230 27.6 Providing and fixing Aluminum composite panels Silver colour with matte finish, 3mm thick, (0.25mm 2.5mm and 0.25mm) sheet for name plate including writing with computerized vinayle sheet letters of required size including fixing at required placed with 1.25m Chromium plated Steel Pipe 15mm dia, compete as per direction of Engineer-in-Charge. 1231 27.7 Providing and fixing Aluminum composite panels Silver colour with matte finish, 3mm thick, (0.25mm 2.5mm and 0.25mm) sheet for name plate including writing with computerized vinayle sheet letters of required size including fixing at required placed with studs, screws and rawl plugs etc. compete as per direction of Engineer-in-Charge. 1232 27.8 Providing and fixing stainless steel English (Capital) and Hindi letters in standard pattern bellow type made with 1.20 mm thick stainless steel (ASI Grade- 304 ) Depth of letter shall not be less than 30mm and rate includes welding/soldering of joints polishing, buffing and fixing on the wall, plate and beam surface at any height with necessary nut and bolts/fastener wherever is required complete as per direction of Engineer-in-Charge. 1233 27.10 Providing and fixing of prestressed vertically casted concrete panels (both surfaces should be smooth and having grooves on both faces) of M-40 grade of concrete of size 2100x300x50 mm having minimum 4 nos of high tensile steel wire as per IS 6006:2014 of dia 3 mm placed horizontally in full length of panel with prestressed precast concrete column of M-40 grade of size 3000x150x150 mm having minimum 7 nos of high tensile steel wire as per IS 6006:2014 of dia 3 mm placed vertically in full length to erect precast boundary wall panels to height 2100 mm from GL including excavation of pit of size 750x750x900 mm in all kind of soil except rock for erection of columns and grouting the pit with M-20 grade of concrete. Manufacturing, transportation and installation at site all complete as per the direction of Engineer-in-Charge. 1234 27.11 Extra for every additional height of 0.3 m up to height of wall 3 m 1235 28.35 Providing and fixing of 3 seater stone bench made of 75mm thick stone slab finished by different numbers of ambry stone and two coats of 124 no sealer coat to prevent from weather including fixing on a pedestal (cost of pedestal to be paid separately)etc. complete as per direction of engineer in charge. Size: length 1500mm, width 600mm, legs height 500 mm, back support height 500mm. 1236 28.36 Providing and fixing of stone planter (bench) made of 75mm thick stone slab finished by different numbers of ambry stone and two coats of 124 no sealer coat to prevent from weather including fixing on a pedestal (cost of pedestal to be paid separately)etc. complete as per direction of engineer in charge. Size: length 1200mm, width 500mm, legs height 500 mm. 1237 28.37 Providing and fixing of stone table made of 75mm thick stone slab finished by different numbers of ambry stone and two coats of 124 no sealer coat to prevent from weather including fixing on a pedestal (cost of pedestal to be paid separately)etc. complete as per direction of engineer in charge. Size: length 1000mm, width 600mm, legs height 750 mm. 1238 28.38 Providing and laying C.C. pavement of mix M- 25 with ready mixed concrete from batching plant including centering and shuttering complete. The ready mixed concrete shall be laid and finished with screed board vibrator, vacuum dewatering process and finally finished by floating, with wire brush etc. complete as per specifications and directions of Engineer- in-Charge.Note: Cement content considered in this item is @ 330 kg/cum. 1239 29.1 Preparation of site plan and location plan with total station surveying showing all individual structures and features like trees, roads, culverts, nallas, electric poles, telephone poles, sewer lines, chambers, water supply lines, hand pumps, well etc. complete along with showing location of roads proposed in master plan. i/c Contours of entire area at 0.5 m. intervals using auto level, preparing of site plan in soft copy (using autocad) in suitable scale as desired by engineer-in-charge duly indicating north direction. Rate includes providing 1 digital copy and six hard copies, one print on tracing film, khasra map duly showing the land and location plan (index plan) and google image of the land. Rates are inclusive of transportation charges. (Work shall be got done through consultants duly empanelled with chief Architect MP P.W.D.) 29. 1.1 Upto 1 Hectare 29.1.2 1 Hectare to 2 Hectare 29.1.3 Add extra for each additional one Hectare or part there off 29.1.4 Excavation of trial pit of size 1.20 m X 1.20 m with minimum depth of 0.9 m and maximum depth of 3.5m as directed by the Engineer in Charge. Trial pit shall be taken at suitable location/ locations as directed by Engineer in charge and shall be indicated on the site plan showing details of soil strata. 1240 29.2 Preparation of double line plan after measurement of internal as well as external dimensions of existing buildings/structures and plotting the same in suitable scale as directed by Engineer-in-charge. 1241 29.3 Preparing of double line plan for planning of addition and alteration work after measurement of internal as well as external dimensions and details of existing door window, ventilator openings and partitions, addition /alteration done previously in buildings/structures and plotting the same separately showing sectional elevations (minimum two numbers) and all elevations along with all relevant details like doors, windows stairs etc in suitable scale as directed by Engineer-in-charge. The consultant shall also submit detailed condition survey report. 1242 29.4 Performing Plate Load Test (P.L.T.) for Determining soil bearing capacity (SBC) at site including submission of Geotechnical Report and recommending bearing capacity in accordance with IS-1888-1982 (Without Conveyance). 1243 29.5 Performing Standard Penetration Test for determining soil bearing capacity (SBC) in accordance with IS-2131-1981 and submission of Geotechnical Report on bearing capacity based on SPT in accordance with IS-6403-1981 (Without Conveyance) 1244 29.6 Transportation charges for transportation of Geotechnical testing equipments for plate load test or standard penetration test upto a distance of 100km. (upto 100km going and 100km returning from district H.Q. both way) Rates are inclusive of Loading and unloading of testing equipments and other incidental charges during both journeys to be paid only once for one set (separate for PLT or SPT) of testing. 29.6.1 Up to 100km (both way) 29.6.2 Add extra for distance beyond 100km and upto 150km. (both way) 29.6.3 Add extra for every additional km beyond 150km (both way) 1245 29.7 Preparation of detailed estimate on the basis of the working drawing supplied by the department and current SOR applicable, including computation of bill of quantities (BOQ) of material and supplying the same in six hard copies and one soft copy to the Engineer-in-Charge and if required revision of the same without any additional charges. (Work shall be got done through consultants duly empanelled with chief Architect MP P.W.D.) The estimate shall be prepared only in standard format prescribed as per appendix 14 of this SOR. 1246 29.8 Preparation of DPR including site visit to verify contours & soil reports and preparation of master plan of campus including architectural working drawings and estimates in prescribed format as per appendix 14 of this SOR to obtain AA; and there after architectural drawings for statutory approvals and detail drawings at construction stage; and as constructed drawings on completion of work the DPR. Bifurcation of professional fee payable in stages as per this item shall be in accordance with List-1, List-2 & List-3. Given in preambles of this chapter 3.All work such as preparation of DPR, working drawings, statuary drawings, details drawings and as constructed drawings shall be done by the same architect/consultant to ensure consistency in services, even if time required to complete all stages as per Activity sheet exceeds the contract period. 1247 29.9 Preparation of the structure design & drawings by a structural engineer empanelled with the Chief Architect MP PWD on the basis of architectural drawings supplied/approved by the department, in accordance with relevant codes/manuals and according to the Terms & Conditions, prescribed in Activity Sheet No-1, List-4 given in Annexure-14 appended with SOR. Design and drawing shall also include ‘Tables’ for the bar-bending schedules (BBS) and concrete/steel consumption. The design and drawing shall be submitted to the Engineer-in-Charge in six hard copies and one soft copy for execution. The payment shall be done in accordance with relevant stage in activity sheet and list. 29.9.1 First time design work 29.9.1.1 Built up area upto 500 sqm 29.9.1.2 Built up area more than 500 sqm and upto 3000 sqm 29.9.1.3 Built up area more than 3000 sqm. 29.9.2 Repetition of structural design of a structural design done by the structural himself or by any other structural engineer at different site, where S.B.C. or seismic zone is different.(only plinth area payment to be paid) 29.9.2.1 Plinth area upto 500 sqm 29.9.2.2 Plinth area more than 500 sqm and upto 3000 sqm 29.9.2.3 Plinth area more than 3000 sqm 1248 29.10 Assessment of load carrying capacity and structural soundness of existing building mainly comprising of R.C.C. structure using existing information such a existing drawing, design and footing details, if available. The consultant shall carry out destructive/non destructive testing of structure at site including site investigation which may require opening of footings by digging adjoining ground fill and restore backfill structure after testing is done. This work shall be performed by a structural engineer (proof checking) empanelled with the chief Architect MP PWD Bhopal or any government engineering college. The rate shall include all charges for labour, testing, consultation of geotechnical consultant and site visit to carry out site testing Per Sqm (built up area of wing/block of existing building where construction is proposed). 1249 29.11 Drafting structural drawing on the basis of the structural design supplied by the department in accordance with all relevant codes/manuals and as per IS: 1893- 2002 and IS: 13920-1993 with updation. The work shall include making revision/compliance if any and obtaining approval of drafting work, without any additional cost within time specified by the Engineer-in-Charge or from the competent authority. The drawings for approval shall be submitted to the Engineer- in- Charge in two hard copies (minimum size A-2) and there after fair drawings on 100 micron film along with seven copies of amonia prints (minimum size A-1) and one soft copy. Drawings shall be stamped and signed with the statement that Drafted by me as per structural design done or got done by the department. Note:- This work can be done only through a person having qualification of Diploma in civil engineering/BE (civil engineering) and having certificate in AutoCAD issued by AutoDesk or by its authorized institution.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 5
Madhya Pradesh View Result →
11.
Defence #9749550 AOC
Tender For Provision Of Deficient Married Accommodation At Air Force Station Phalodi Boq (11 Aug 2025).; 1 NOTE: Schedule ‘A’ Part I to XII under Ser No. 1.00to 12.00 are prepriced by MES. Bidders shall insert their lumpsum amount in the green coloured field under Col-6 only. 2 Lump sum price worked outfor BUILDINGS/ STRUCTURES as listed in Sch A Part I. 3 Lump sum price worked out for EXCAVATION, EARTH WORK AND SITE CLEARANCE as listed in Sch A Part II 4 Lump sum price worked out for INTERNAL ELECTRIFICATION as listed in Sch A Part III 5 Lump sum price worked out for INTERNAL WATER SUPPLY as listed in Sch A Part IV 6 Lump sum price worked out for SEWAGE DISPOSAL as listed in Sch A Part V 7 Lump sum price worked out for AREA DRAINAGE as listed in Sch A Part VI 8 Lump sum price worked out for ROAD/ PATH as listed in Sch A Part VII 9 Lump sum price worked out for FENCING/GATE as listed in Sch A Part VIII 10 Lump sum price worked out for EXTERNAL ELECTRIFICATION/STP as listed in Sch A Part IX 11 Lump sum price worked out for EXTERNAL WATER SUPPLY as listed in Sch A Part X 12 Lump sum price worked out forRAIN WATER HARVESTING as listed in Sch A Part XI 13 Lump sum price worked out for HOT WATER SUPPLY as listed in Sch A Part XII 14 SCHEDULE A PART - XIII MISCELLANEOUS ITEMS is not prepriced by MES and prepriced rates indicates 0.0 under column 5 signifies this fact only. Bidder shall insert their rates in Green filed under Col-6. 15 SITE CLERANCE & DEVELOPMENT 16 M & L for Surface excavation n.exc30 cm deep and averaging 20cm deep and getting out top layer arqanie soil without disturbing or destroy its texture and remove the same to a location specified and stored properly for relaying after the completion of building work exc 50m but n exc 250m complete all as specified and as directed 17 Relaying the soil excavated in Item no 13 to building site for landscaping and gardening complete all as specified and directed 18 S&F colour coaded plastic dustbins of 120 Litre capacity each in Green/Blue/Red in colour as directed by GE , made of high grade UV resistant polyethylene, suitable for segregation of biodegradable, recyclable, hazardous and sanitary waste bins to be durable , Light weight, weatherproof, easy to clean with tight fitting lids and clear identification lables complete all as specified and directed..Note :-Labelling on dustbin are as follows:a) Green color waste bin :- Bio degradable wasteb) Blue color waste bin :- Reusable/ Recycle waste c)Red color waste bin :- Land Fill waste 19 INTERNAL ELECTRIFICATION 20 S & F for wall mounted LED box type tube light fitting 4 x 20 watts industrial commercial interior batten for surface mounted, anodized extruded aluminium housing, high transmissitivity diffuser, high lumen ouputboxtype fitting, 230 volts and intregrated electronic driverconnector block etc with warranty option of 5 years from date of installation complete with all accessories internally pre wired andnecessary mounting arrangements, provision of new 3 core multistrandedcopper conductor of size 23/0.193 from ceiling rose to fitting complete all as specified and as directed. 21 S & F forLED tube light fitting with aluminium housing 2 feet x 10 watts mirror type with high out put diffuser, decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cableof suitable sizefrom ceiling rose to fittingwith warranty option of 5 years from date of installationcomplete all as specified and as directed. 22 S & F forLED tube light fitting with aluminium housing 2 feet x 5 watts mirror type with high out put diffuser, decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cableof suitable sizefrom ceiling rose to fittingwith warranty option of 5 years from date of installationcomplete all as specified and as directed. 23 S & F for Decorative wall mounted luminaire made out of Nickle finesh square base with bend pipewith unbreakable globe glass suitable for LED bulb and provosion of LED bulb 10 watts complete all as specified and as directed. 24 S & F for ceiling fan, 230 Volts, 1200 mm sweep with mian air delivary 210 CFM, service value of the fan shall be greater than 6.1 (5 star rated) as per BIS with blades, down rod & other necessary accessories with brushless direct current motor (BLDC)with remote system and electrical connections from ceiling rose to fan teriminal complete all as specified and directed. 25 S & F for energy efficient exhaust fan of 225 mm sweep made of metal body Ventil Air -DS type complete with louver with bolts nuts and washers size of the bolt 15 cm long 12 mm dia embedded in the wall including provision of PVC flexible copper cable of size 23/0.0076 two core from ceiling rose to exhaust fan forconnection and making suitable size ofhole to existing wall for fan base compelte all as specifiedand directed.(Note : Cost of suitable opening wall for fixing exhaust fan is deemed to be includedin overall rate quoted). 26 S & F for energy efficient exhaust fan of 300 mm sweep made of metal body Ventil Air -DS type complete with louver with bolts nuts and washers size of the bolt 15 cm long 12 mm dia embedded in the wall including provision of PVC flexible copper cable of size 23/0.0076 two core from ceiling rose to exhaust fan forconnection and making suitable size ofhole to existingwall for fan base compelte all as specifiedand directed.(Note : Cost of suitable opening wall for fixing exhaust fan is deemed to be includedin overall rate quoted). 27 Supply, installation, commissioning and testing indoor type LT wall mounting Bldg panel board of suitable sizefactory made TTA panel, weather, dust & vermin proof indoor, double door, front openable, locking arrangements made out of 2.00 mm thick mild steel CRCA sheet including required comparment for fixing of four (12) Nos single phase smartmeter, MCCB and MCB and porviding glass view for reading of meter and providing rubber/ PVC gasket of suitable size all sides of door, with copper busbar wrapped with PVC tape/ sleeves with maintained the colour code and copper strip/ wire busbar of suitable size to MCCB input and MCCB/ MCB output of suitable length for connection of cable from main busbar, angle iron 50 mm x 50 mm x 5 mm thick supporting frame including applying two coats of powder coated paint over a coat of red oxide zinc chrome primer over exposed external & internal surfacesfor 3 phase 4 wire system 415/ 440 volts grade including internal wiring connections for all outgoing / incomming cable,earthing teminals , danger plate, suitable PCC platform complete all as specified and directed 28 INCOMING(a) Copper strip busbar of suiable of capacity 200 Amps rating wrapped with PVC sleeves with maintained the colour code and provision of making holes with Copper nuts, bolts & washers for cable connections including hydrograpic insulators with nuts & bolts at both ends= 04 Nos.(b)MCCBIP 44 and IP 66/67 protection, 4 pole, 415 volts, Lcu=25 KA breaking capacity, rating 100 Amps, adjustable thermal magnetic release including all fixing accessories with both ends spreader links -01 No.(c) Digital voltmeter of range (0-500) volts, flush mounting type of size 100mm x 100mm (4”x4”) square dial with selector switch – 01 No(d)LED Neon indicator lamp (RYB) with holder,230/250 volts,AC -01 set (set of three) Make :- AE/L&TOUTGOING(a) MCB, Single pole & neutral, 40 amps, 240 volts, ‘C’ curve, 10 KA allcomplete as specified and as directed - 12 Nos (Officers Accn)(b) MCB, single pole & neutral, 10 amps, 240 volts, ‘C’ curve, 10 KA allcomplete as specified and as directed - 1 No (Stair case lighting)(c) Slot for fixing the three phase smart prepaid meter - 13 Nos (Cost of Smart meter cost will be paid seperately under respective itemly) 29 Supply, installation, commissioning and testing indoor type LT wall mounting Bldg panel board of suitable sizefactory made TTA panel, weather, dust & vermin proof indoor, double door, front openable, locking arrangements made out of 2.00 mm thick mild steel CRCA sheet including required comparment for fixing of four (07) Nos single phase smartmeter, MCCB and MCB and porviding glass view for reading of meter and providing rubber/ PVC gasket of suitable size all sides of door, with copper busbar wrapped with PVC tape/ sleeves with maintained the colour code and copper strip/ wire busbar of suitable size to MCCB input and MCCB/ MCB output of suitable length for connection of cable from main busbar, angle iron 50 mm x 50 mm x 5 mm thick supporting frame including applying two coats of powder coated paint over a coat of red oxide zinc chrome primer over exposed external & internal surfacesfor 3 phase 4 wire system 415/ 440 volts grade including internal wiring connections for all outgoing / incomming cable,earthing teminals , danger plate, suitable PCC platform complete all as directed 30 INCOMING(a) Copper strip busbar of suiable of capacity 120 Amps rating wrapped with PVC sleeves with maintained the colour code and provision of making holes with Copper nuts, bolts & washers for cable connections including hydrograpic insulators with nuts & bolts at both ends= 04 Nos.(b)MCCBIP 44 and IP 66/67 protection, 4 pole, 415 volts, Lcu=25 KA breaking capacity, rating 63 Amps, adjustable thermal magnetic release including all fixing accessories with both ends spreader links -01 No.(c) Digital voltmeter of range (0-500) volts, flush mounting type of size 100mm x 100mm (4”x4”) square dial with selector switch – 01 No(d)LED Neon indicator lamp (RYB) with holder,230/250 volts,AC -01 set (set of three) Make :- AE/L&TOUTGOING(a) MCB, Single pole & neutral, 40 amps, 240 volts, ‘C’ curve, 10 KA allcomplete as specified and as directed - 06 Nos (Officers Accn)(b) MCB, single pole & neutral, 10 amps, 240 volts, ‘C’ curve, 10 KA allcomplete as specified and as directed - 1 No (Stair case lighting)(c) Slot for fixing the three phase smart prepaid meter - 07 Nos (Cost of Smart meter cost will be paid seperately under respective itemly) 31 M & L for maintenance free Chemical earthing of technology with copper bonded steel rod 3 mtr long 25.0 mm dia with 250-micron Copper bonded coating and UL listed. There should be terminal for connection of 150 x 50 x 6 mm with 4 holes of 12 mm dia along with 2 bags of 25 Kgs each of earth enhancing compound. The chemical compound should be tested and certified by any NABL accredited laboratory with 95 percent carbon content. The testing laboratory should be an ISO 9001 and 14001 certified. The earth enhancing compound should be IEC 62321. The ph value of compound should be 7-8. Electrode should be duly tested and certified by CPRI, Govt of India for a min short circuit current of 25 kA rms for 1 Sec. including necessary boring of suitable dia upto required depth in any type of soil for inserting copper rod and filling of chemicals and Poly plastic pit cover of material- polymer body & cover dimensions- 308 mm (L) x 308 mm (W) x 214 mm (H) bearing capacity 7.5 Ton approved from NABL approved Lab complete all as specified and as directed. 32 Note:-(i) Earthing is to be done infront of the Engr-in-Charge.(ii)Test Results of earthing to be submitted by the contractor for all earthings.(iii)The Contractor shall have to give written guarantee for maintenance earth resistance of less than 1.0 Ohm for the period of 10 9ten) years after certified date of completion and shall bdeposited 2000/- per earthing as security deposit for a period of Ten (10) Years.(iv)Failing to maintain resistance of earthing less than 01.0 ohm , new earthing to be provided by the contractor with out any extra cost.(v)Necessary earth work, excavation shall be carried out in any type of soil strata, retuning, filling in and making good surronding area complete. 33 Supply and Installation of Smart Single Phase Meter of different makes (Not more than 33 % of a particular make) including polycarbonate boxes with transparent cover to view meter display with the following specifications:(a) AC Single Phase Two Wire, Tamper Proof, Static Meter of Class 1.0, 240 V, 50 Hz, 5A-60A, with 3200 impulses per KWh,LED forPhase presence & LED for Relay status, conforming to IS-16444 standard with inbuilt 865-867 MHz 6 Low PAN Mesh Radio Frequency communication facility with self healing Mesh network with default and on demand display, billing data generation facility, anti-tamper features, Microprocessor and LCD based display only with compatible IP54 compliant polycarbonate box for outdoor mounting with optical port Provision on meter box. Meter Should support the following data : 15/30 min instantaneous data for Voltage, Current, Power factor, Power, Cumulative energy and frequency, monthly billing data & antitamper features. Load survey data for 45 days with 30 min integration period for kWh, Voltage, Current, frequency etc.Meter should have connect / disconnect functionality operable from prepaid billing software & shall show balance on displayThe meter should support open communication protocol DLMSwith the softwareNote :-(a) It should run the meter in both prepaid and postpaid mode(b) The meters should carry 5 year warranty.(c) OEM shall have own NABL accredited lab for testing meters as per IS 16444 and certification shall be provided during sample approval(d) The meter cost would include DCU/ Gateway and repeater cost for RF commuication meters 34 Supplying, Fixing, Commissioning and testing of configuration of cloud based prepaid software forwith following modules: (i) Meter Data Management Module: The meter data management module would be responsible for collecting the data from the data concentrator and make the data available to the billing system. The system would support offline meter data entry.The meter data management system would capture and provide the following data:(a) 30min instantaneous data from all the meters for seven parameters- Cumulative Energy,Power, Current, Voltage, Power factor and Frequency.b) Monthly and quarterly billing survey data for cumulative energy and max demand, Load Survey Data, Tamper Events(ii) Communication module: The system should provide communication of energy data and bills via print, email.(iii) Meter Master Data : The system would support meter data repository. The system should support meter replacment process.(iv) Excel Export : The system would support export of metering and billing data in excel formatNote:- (i). Software will be compatible with all makes of smart meter & shall be CERT-IN certified from CERT approved vendors for any cyber security related threat & complying as per ENC guidelines.(ii) It shall also include recurring SMS charges, Email gateway integration charges, payment gateway charges for online meter recharge etc & shall be included in quoted rate for 2 years DLP period.(iii) Provision for comprehensive operation including periodic charges of telecom operator, smart meter billing from completion of work till the competion of defect liability period of 2 years.(iv) The software would be hosted on MEITY GCC approved server. 2 years hosting costs would be included. 35 INTERNAL WATER SUPPLY 36 S & Fchromium plated fancy type Angle cock with wall flange quarter turn (flow rate 6Liter per minute) 15 mm dia. complete all as specified and directed Make :Hindware/Cera/Jaquar /Kohler (GRIHA certified fittings) 37 S & FChromium plated fancy type two way Angle cock with wall flange quarter turn (flow rate 6Liter per minute) 15 mm dia. complete all as specified and directed Make :Hindware/Cera/Jaquar /Kohler (GRIHA certified fittings) 38 S & FChromium plated fancy type Bib cock with Aerator quarter turn (flow rate 6Liter per minute) 15 mm dia. complete all as specified and directed Make :Hindware/Cera/Jaquar /Kohler (GRIHA certified fittings) 39 S & FChromium plated fancy type Pillar cock with Aerator quarter turn (flow rate 6Liter per minute) 15 mm dia. complete all as specified and directed Make :Hindware/Cera/Jaquar /Kohler (GRIHA certified fittings) 40 S & FChromium plated fancy type Sink cock(wall mounted) with Aerator long shunk quarter turn (flow rate 6Liter per minute) 15 mm dia. complete all as specified and directed Make :Hindware/Cera/Jaquar /Kohler (GRIHA certified fittings) 41 S & F Chromium plated fancy type Wall Mixer 3 In 1 (flow rate 6 liter per minute) with flange Provision For Overhead Shower with 115mm Long Bend Pipe On Upper Side, Connecting Legs & Wall Flangescomplete all as specified and directed.Make - Hindware/Cera/Jaquar /Kohler (GRIHA certified fittings) 42 SEWAGE DISPOSAL 43 Supply, laying and testing of 150mm internal diameter of double wall corrugated (DWC) high density polythylene pipes (HDPE) and stiffness classes-8 (SN-8) with ISI marked(with CML no) with and including all fitting & jointing material for sewage line and laid in trenches as specified in IS 16098-2013 Part-2 complete all as specified and as directed. Note : Bedding of pipe shallbe provide as per theconstruction methods ,andshall be strictly compiled as per clause No A-4 of Annex A of IS 16098 Part II 44 Supply, laying and testing of 200mm internal diameter of double wall corrugated (DWC) high density polythylene pipes (HDPE) and stiffness classes-8 (SN-8) with ISI marked(with CML no) with and including all fitting & jointing material for sewage line and laid in trenches as specified in IS 16098-2013 Part-2 complete all as specified and as directed. Note : Bedding of pipe shallbe provide as per theconstruction methods ,andshall be strictly compiled as per clause No A-4 of Annex A of IS 16098 Part II 45 SEWAGE TREATMENT PLANT(STP) 46 Supplying, Design , Construction, Hydraulic testing , Commissioning and giving satisfactory trialsSTP of capacity 10KLD consisting of PMF Technology based along with the following accessories to the desired capacity of 10 KLD rated net outputcomplete as turnkey jobwith all involved electrical and mechanical componentsfor satisfactory performance of plant andrequired treated outlet waterparameters as per E-in-Cs Br Policy No 05/ 2023 dated 04 May 2023 complete all as specified and directed(a) Construction RCC tanks of following sizes:-(i) Septic tank of size - 3.70 Mtr x 1.80 Mtr x 1.50 Mtr - 01 No(ii) PMF tank of size - 4.20 Mtr x 2.80 Mtr X 1.20 Mtr- 01 No(iii) Filter Feed tank of size- 1.70 Mtr x 0.80 Mtr x 1.50 Mtr - 01 No(iv)Treated Water tank of size- 1.70 Mtr x 0.80 Mtr x 1.50 Mtr - 01 No(v)Chamber between PMF & FFT of size- 0.45 Mtr x 0.45 Mtr x 0.45 Mtr - 01 No(vi) Manhole Chanber made out of brick work im CM 1:6 suitable size with FRP Manhole Covers of size - (600 mm x 600 mm) - 05 Nos 47 (b) Supply & laying of Stone course aggregate of following sizes:-(i) 8 size (200 mm) - 2.60 Cu mtr(ii)4 size (100 mm)- 2.60 Cu mtr(iii)2 size (50 mm) -2.60 Cu mtr(iv)Coarse Sand - 2.60 Cu mtr(c) Supply & laying of Bacterial Culture ( suitable for degrading sewage-1200.00 KG(d) Supply & plantingof saplings Canna Indica - 60 Nos(e) S & F for Non-clog submersible Raw sewege Pump, Single phase, 230 Volts, 50 Hz of discharge capacity 0.63 cum/ Hr @ 10 Mtr head complete- 02 Nos (01 W+ 01 S) (f) S & F for Submersible opern well pump set, Single phase, 230 Volts, 50 Hz for fresh treated water application discharge capacity 0.63 cum/ Hr@ 25 mtr head complete- 02 Nos (01 W+ 01 S) (g) Supply and install for heavy duty chemical dosing system plunger type suitable to injet solution with suitable capacity, working pressure10 Kg/cm2, comprising dosing pump coupled with 3 phase electric motor of suitable capacity, 1440 rpm assembly with Agitator in one motor , Agitator with stainless steel sweepblade duly FRP coated, FRP tank suitable capacity, complete unit mounted on heavy duty MS fabricated frame duly anti corrosive paint complete with chemical grade PVC NRV along with control panel for dosing pump suitable made of power coated MS fabricated box consting of LED indicater, digital Voltmeter, single phase preventor, high voltage, low voltage protection complete - 01 Job 48 (h) S & F for of PSF (Pressure sand filter) of size 250 mmin dia and height 1.30 mtr made out of FRP material suitable for withstand of 2.50 kg/cm2 pressure with multi port valve and interlinking piping - 1 Job(j) S & F for for ACF (Activated Carbon Filter) ofsize 250 mmin dia and height 1.30 mtr made out of FRP material suitable for withstand of 2.50 kg/cm2 pressure with with multi port valve and interlinking piping - 01 Job(k) S & F for UPVC Pipe of sizes 25 mm dia & 40 mm dia suitable with stand the pressure 6 kg/cm2 as required- 01 Job(l) S & F for copper conductor multistranded 3 core cable PVC insulated sheathed calble of size 2.5 Sqmm for motor connections from starter panel to motor control connector as required- 01 JobNote:-Components/ units/ Equipment/ accessory for PMF Technology based STP is as perdesign and indicative . However OEM can add/ alter/ omit the given components as per their design to achieve desired capacity and treated outlet water parameter with same technology as per E - in- Cs Branch New Dehli guidelines/ policies . 49 Supplying, Design, Construction, Hydraulic testing , Commissioning and giving satisfactory trials for Chop Whoop Winding Process MBBR/ JOHKASOU based FRP Underground Package STP along with the following accessories to the desired capacity of 30 KLD rated net output, complete as turnkey job with all involved electrical and mechanical components complete all as specified and directed for satisfactory performance of plant and required treated outlet water parametersas per E-in-Cs Br Policy No 05/ 2023 dated 04 May 2023Note:- The STP shall be designed based on the inlet & outlet parameters of E-in-Cs Branch above policy.(a)Chop Whoop Winding Process MBBR/ JOHKASOU based FRP Underground Package STP inclusive of Solid Separation, Anoxic Zone, MBBR Aeration Zone & Final Sedimentation zone Tank of size 8440 mm (L) x 2430 mm (dia) Tank- 01 No(b)Chop Whoop Winding Process based FRP Underground Intermediate Water Storage Tank 10 KL of size 4310 mm (L) X 1830 mm (dia) Tank- 02 Nos(c) With socket provision on tanks as per the design of UPVC return sludge pipe 50mm dia, PVC inlet outlet pipe 150mm dia, PVC interconnection pipe of 150mm dia, UPVC 80 mm dia, FRP Straps, Turn Buckle Wire Rope, Concrete Deadman & Eye Bolts per the diameter & length of the tank, Manhole cover as per the drawing, PVC air vent nozzle of dia 50mm, manhole cover of size 550mm dia, etc- 01 Job.(d) S & F for On-Ground LLDPE Treated Water Storage Tank of 10 KL Capacity of size2550 mm dia x 2510 Height- 01 No(e)Supply installation, testing and commissioning of cubical type Relay Based Control Panel out door type madeout of 3.15 mm thick CRCA sheetof suitable size suitable for 415V, 3 Phase, 4 wire, 50 Hz AC with necessary MCCB for incoming , copper busbar, MCB for out going & necessary DOL stater etc- 01 Job 50 (f)Twin lobe rotary Air compressor capable of delivery 56 Cum /Hr suitable volume of free air at 0.27 - 0.37 kg/sq.cm, discharge Pressure 0.2 - 0.3 kg/cm2g, Noise Level at 1.5 m distance: <70-80 (DBA),Body rotter made out of EN19 with FG260 & FG-260(CI), Silencer Fabricated with MS material.driven through V belt or directly coupled though flexible coupling to a TEFC motor of suitable capacity 1440 RPM, 415 Volts, 3 Phase,50 Hz, Pressure guages-01 No,150 mm NRV -01 No, Butterfly shut off valve, air filter, cleaner etc including 3 core copper cable multistranded connection of suitable size from starter to air compressor assembly complete all as specified and directed. 02 Nos (1W + 1S)(i)UPVC pipes 80 mm bore, conforms to ASTM D-1785, SH-80, with all fittings and fixtures ASTM D-2467, SH-80, laid in floors or fixed to wall, etc. including necessary fixing works complete all as specified- 01 Job(g) Sludge Recycling Pumpof non clog submersible sewage pump set suitable to handle domestic sewage water (having PH value 7 and solid particle size 20 mm) with suitable for delivery pipes with one non return valve pump set suitable with Flow Rate 9.0 m3/hr, Head 10 Mtr (1.0 HP) for operation at 415Volts frequency 50Hz, 3 Phase- 01 No (1W) (For Sludge recycling in Solid Separation zone)- 01 Job(i)The pumps shall have CI casing, motor body, Impeller & gland packing. The motor type shall be a squirrel cage induction motor with F class insulation. (ii)UPVC pipes 50 mm bore, conforms to ASTM D-1785, SH-80, with all fittings and fixtures ASTM D-2467, SH-80, laid in floors or fixed to wall, etc. including necessary fixing arrangements complete all as specified- 01 Job(h) Pressure Sand Filter Capacity 3.0 cum/hr made out ofFRPSide Mounted of Size: 21 x 62,workingPressure 10 PSI, Filter Media, Pebbles & Filtering Sand, PVC Piping 50 mm Size (UPVC), Multiport Valve (Manual)-01 Job 51 (j)Activated Carbon Filter Capacity: 3.0 cum/hr, made out ofFRPSide Mounted of Size: 21 x 62, workingPressure 10 PSI, Filter Media: Activated Carbon 900 - 1100I/V,PVC Piping 50 mm Size (UPVC), Multiport Valve (Manual)-01 Job(k)Chlorine (Sodium Hypochlorite) Dosing Pump of Capacity 0-6 LPH, PTFE Diaphragm, single phase 230 Volts, 50 Hz including with HDPE Chlorine Dosing Drum of Capacity 100 Ltrs and necessary connections etc- 01 Job(l) Filter feed pump of non clog submersible sewage pump set suitable to handle domestic sewage water (having PH value 7 and solid particle size 20 mm) with suitable for delivery pipes with one non return valve pump set with Flow Rate 3.0 m3/hr, Head 15-20Mtr (1.0 HP), suitable for operation at 415 Volts, 50Hz , 3 Phase- 02 Nos (1W+1S) (For pumping into PSF & ACF Filters)- 01 Job(i)The pumps shall have CI casing, motor body, Impeller & gland packing. The motor type shall be a squirrel cage induction motor with F class insulation. (ii) UPVC pipes 50 mm bore, conforms to ASTM D-1785, SH-80, with all fittings and fixtures ASTM D-2467, SH-80, laid in floors or fixed to wall, etc. including necessary fixing arrangementscomplete all as specified- 01 Job(m)Raw sewage Water transfer Pump of non clog submersible sewage pump set suitable to handle domestic sewage water (having PH value 7 and solid particle size 20 mm) with suitable for delivery pipes with one non return valve pump set with Flow Rate 9.0 m3/hr, Head 10-15 Mtr (1.0 HP) suitable for operation at 415 Volts, 50Hz , 3 Phase- 02 Nos (1W+1S) (For pumping from Raw Sewage Collection tank into the Bar Screen Chamber)- 01 Job(i)The pumps shall have CI casing, motor body, Impeller & gland packing. The motor (k) Ctype shall be a squirrel cage induction motor with F class insulation. (ii)UPVC pipes 50 mm bore, conforms to ASTM D-1785, SH-80, with all fittings and fixtures ASTM D-2467, SH-80, laid in floors or fixed to wall, etc. including necessary fixing arrandements complete all as specified- 01 Job 52 (n) Treated Water transfer Pump of Monoblock pump set suitable to handle domestic treated water (having PH value 7 and solid particle size 20 mm) with suitable for delivery pipes with one non return valve pump set with Flow Rate 9.0 m3/hr, Head 10-15 Mtr (1.0 HP) suitable for operation at 415 Volts, 50Hz , 3 Phase (1W+1S) (For pumping from treated water zone to reuse)- 01 Job(i)The pumps shall have CI casing, motor body, Impeller & gland packing. The motor type shall be a squirrel cage induction motor with F class insulation. (ii)UPVC pipes 50 mm bore, conforms to ASTM D-1785, SH-80, with all fittings and fixtures ASTM D-2467, SH-80, laid in floors or fixed to wall, etc. including necessary fixing arrandements complete all as specified- 01 Job(o) Fine bar Screen with chamber (manual) of SS 304 for screening 5 to 6 mm particles of size 1.0 Mtr x 1.0 Mtr at inlet of MBBR tank- 01 Job 53 Note : - (i)The Package STP tank shall be made from 100% FRP Material through Chop Whoop Winding Process with compliance and certification/approval in UL 1316 from the UL LLC that is Underwriters Laboratories LLC.(ii)The FRP tanks shall be made using Isopthalic Unsaturated Polyester Resin.(iii) The Sewage Treatment Plant system shall have a valid certificate of a Green product from a reputed Government or Third party having authority to certify like CII, IGBC, Assocham or any other body having competence in issuing such certificates.(iv)The shell thickness of the tank shall be between 6.50 mm to 7.50 mm (±0.5 mm) & Dish end thickness must be 11 mm and above made only from 100% FRP material(v)Technology must be empanelled in CPHEEO Sewage Manual.(vi)Minimum Hydraulic Retention time of the total Package STP system/tank must be 22.00 hours.(vii)Minimum sludge handling should only be once a year(viii)STP must function from minimum load of 5 - 10% to 100%. (Minimum load to Peak Load)(ix)The STP must have an anoxic zone for denitrifuication(x)Minimum volume of Intermediate Water Storage tank in FRP MOC must be 10 KL(xi)Minimum volume of Treated Water Storage tank in LLDPE MOC must be 10 KL 54 Material and Labour for Motor ControlLT Panel factory made, Type Test Assemble (TTA) Panel for working on 3 phase, 4 wire, 415 Volts, AC, 50Hz, cubical,outdoor type, weather proof, water proof, dust proof, vermin proof, shock proof protectionmade out3.15 mm thick CRCA sheet of suiitable size accommodate accessories/ fittings with front and back double door opening/ lockable by the key from both side with IP 65 Protection and provn of suitable bus bar chamber and switch gear compartments for MCCB incoming & out going feeders etc with copper extension links of suitable curent carrying capacitty not less than 1.5 times the rated current carrying capacity of MCCB individual feeder supported on DMC/ Epoxy insulator including provison for termination with incoming and out going cables with cable glands. Motor Control LT Panel shall be mounted on 50 x 50 x 6 mm size MS angle iron frame duly painted with two coats of black bituminus paint over a coat of red oxide primer including PCC foundation of suitable size with PCC 1:2:4 type B1(using 20 mm graded stone aggregate) complete including the following accessories:-. 55 IN COMING:-(i)Copper strip busbar of 60 Amps rated capaacity wrapped with PVC sleeves with maintained the colour code and provision of making holes with Copper nuts, bolts & washers for cable connections including hydrograpic insulators with nuts & bolts at both ends= 04 Nos(ii) On load change over Switch TPN of capacity 32Amps - 01 No (iii) 4 Pole MCB of capacity 5-32 Amps 10 KA breaking capacity C curve-01 No(iv)LED Neon indicator lamp (RYB) with holder and fuse holder 230/250 volts, AC -01 set (set of three) (v)Digital Multifunctional meter , flush mounting type with CT’sand selector switch – 01 set.OUT GOING :-(b) MCB SPN 5-32 Amps 10 KA breaking capacity C curve-04 Nos(c) DOL starter single phase with suitable relay range conforming to IS -1347(Part IV) suitable for discharge capacity 6.4 LPM ( 0.38 Cumt/Hr)at 10/25 Mtr head, 0.50 HP, including overload relay, auto timer, indicating lamps (LED) etc complete -04 Nos 56 Supply and laying fordouble wall corrugated (DWC) high density polythene pipes having corrugation on the outer wall and plain surface on the inner wall confirming to ISI 14930 (Part I and II) for protection of underground cables of size nominal outer dia 63 mm & nominal inner dia 50 mm dia with all fittings laid in trenches / road/ nallah or fixed along wall for cable protection all as specified. 57 HOT WATER SUPPLY 58 Supply and installation,commissioning and testing at roof top of building Solar water heating system (Flate Plate Collector) based on indirect transfer of heat of capacity 100Ltr per day with electrical back up of 2 KWas per manufacturers recommednations includinghot water storage tank of capacity 300 ltrs and of 20 guage thickness stainless steel plate (having insulation of rock wool ) mineral wool 100 mm thick & cladding with aluminium sheet 24 SWG complete all as specified and directed. 59 ROAD/ PATH 60 Material and labour for providing and painting 2.5 mm thick road marking strip (retro reflective) of specified shade/ colour using hot thermoplastic material by fully/ semi automatic thermoplastic paint applicator machine fitted with profile shoe, glass beads dispenser,propane tank heater and profile shoe heater, driven by experienced operator on road surace including all cost of material, labour, T&P, cleaning of road surface of dirt, seals, ils, grease and foreign material etc. complete all as specified and directed. 61 EXTERNAL ELECTRIFICATION 62 Supply and fixingfor Cable route indicator / Marker made up of PCC Block in cement mortar 1:3:6 ( 20 mm graded aggregrate ) of size 900 x 300x 100 mm thick with DANGER/ 11 KV CABLE/ MES embossing on cable route Indicator / Marker including painting as per approved colour and buried in ground 45 Cms including necessary earth work ( as required / ordered at site) complete all as specified and as directed. 63 S upply and fixingfor Cable route indicator / Marker made up of PCC Block in cement mortar 1:3:6 (20 mm graded aggregrate) of size 900 x 300x 100 mm thick with DANGER/ LT 433 VOLTS CABLE/ MES embossing on cable route Indicator / Marker including painting as per approved colour and buried in ground 45 Cms including necessary earth work (as required/ ordered at site) complete all as specified and as directed. 64 Supply, installation, Testing and commissioning of Outdoor type (IP 54), 03 way RMU (Ring Main Unit) 11 KV, 630 Amps, 21kA-3 Sec,IP54 SF6 insulated, One side Extensible,consisting of One No (01) motorised vacuum circuit breaker (Incomer) and Twor Nos (02) motorised vacuum circuit breaker (Outgoing) & Metering Panel Bus PT with Top LV, Battery & Battery charger, Ethernet switch & LIU (Configuration VVV+M), inside robotically welded stainless steel 304 (Non Ferrite non Magnetic Grade) tank having min thickness 2.5 +/- 0.5mm with IP 67 degree of protection and enhanced BIL of 75 kVp internally to manager voltage surges and Air Insulated Metering Module of Class-0.5. RMU should be provided with internal busbars, as well as earthing busbars of electrolytic grade copper, padlock provisions & complete with all accessories. The complete RMU must be type tested for Internal arc21KA for 1 sec with AFLR Classification for Gas tank & Cable Chamber as per IEC 62271-200. HT RMU shall preferably have on-site-repairability features such as site replaceable bushing/ coupling/ mechanism and gas refilling to have very less downtime in the event of bushing breakage and restoration can be done at site immediately without sending the RMU to OEM Works, the Vaccum Interrupter must RMU manufacturers own make. The earthing busbar shall be provided inside each cable compartment for solid earthing of cable shields. The outer hinged main door should cover entire front of switchgear including cable doors for providing fail-safe protectioncomplete all as specified and as directed. The unit shall include the following with all necessary standard fitting as required at site.-Make of RMU shall be limited to : ABB/ SIEMENS/ SCHNEIDER INFRASTRUCTURE(Channel partner/ System Integrator/ Authourized Partner/ License partner make RMU shall not be accepted.) 65 (a) Vacuum Circuit Breaker consist of following accessories :-(i)Microprocessor based Numerical Protection Relay for Circuit Breakers - REF615, Feeder Protection and Control Relay, Protections 50, 51, 50N, 51N, 46, 49, 67, 67N, 32, 27, 59, 25, 81U, 81O, 95 Measurement for 3I,I0,3U,U0,Kw,KVA,PF,Hz,Kwh, 16 DI + 10 DO, One front RJ45 Port, One Rear RJ45 Port for IEC-61850 Protocol, Drawout Type with CT Shorting feature, Graphical LCD Display(ii)Capacitive voltage indication fixed type system with LED for all feeder and FPI in all load break switch feeder.(iii)SF6 Gas pressure indicator on the gas tank.(iv)Operating sequence of VCB must be O-0.3Sec-CO-3 Mins-CO amd suitable for 10,000 mechanical operation.(v)CT shall be minimum 50-100/1A ,2.5VA , 5P10 - 3 Nos. for protection(vi)CT shall be minimum 50-100/1A ,2.5VA , Class 0.5 - 3 Nos. for metering(vii)Right angle boot to be provided in each module(viii)2 x12 Volts, 26 AH Battary with Charger - 1 Set(ix)Bus VT shall be 11KV/V3/110V/V3 ,20VA , Class 0.5 - 3 Nos. for metering(x)Auxiliary VT shall be 11KV/230 ,500VA for AC supply input to Battary Charger.(xi)Capacitive voltage indication fixed type system as per IE(xii)Interlocked Cable box for front termination of the cable suitable upto 3 core 120 Sqmm,11 KV XLPE cable (IP3X). Safety interlocked to prevent access to cable termination in live-condition. 66 (xiii)Right angle boots (push on type)(xiv)Cable covers with self Interlocking mechanism between doors, earth switch, disconnector & VCB.(xv)Necessay interclocking arrangement for safety and operations(xvi)One No. Operationg Handle for Manual Operation and one no. manometer(xvii)Safety Interlocks Shall be provided as per relevant IEC/IS Standards and Manufacturers directions.(xviii)Above switchgear shall confirm to all relevant IEC/IS Standards. 67 Supply, installation, commissioning and testing of transformer of capacity 315 KVA, confirming to IS 1180 (Part-1)- 2014 with latest amendment No 4, BEE 3 star rated, EEL 3, step down Outdoor type complete with standard fittings, HT 11 KV 3 phase LT 433 vols, 3 phase, 4 wire corrugated 7 position off circuit tape links of rating + 7.5 to -7.5% @ 2.5% by means of hand operated off load tap changer including necessary control wiringtransformer copper wound, double wound, oil immersed naturally cooled with external cooling tubes core type delta connected on primary side (HV) and star connected on secondary side (LV) in accordance with vector symbol Dyn -11 (vector group with neutral brought on secondary side (LV side) and the maximum temperature rises should not exceed 40 degree centigrade in oil and 45 degree centigrade in HV/LV winding ring measured by resistance after continuous full load run in ambient temp as per IS -2026 per transformer, IS-3639 for fitting & accessories, IS-2099 for high voltage porcelain bushings and the transformer shall be comprised with the following standard fitting with on load tappings on HT side to vary secondary voltage within limit all as per IS -1180 complete all as specified and as directed wit latest policy for following:- 68 Note 01:- (i)Three Nos porcelain bushing suitable for 11 KV on HV side, complete with copper rods, nuts and washers with cable end box.(ii)Four Nos porcelain bushing suitable for 433V on LV side, complete with copper rods, nuts and washers with cable end box.(iii)Monogram plate.(iv)Oil conservator with filter and drain plug.(v)Prismatic/transparent oil gauge.(vi)De-hydrating breather with first fill of dehydrating agent (silica gel).(vii)Thermometer pocket.(viii)Air release plug.(ix) Inspection cover(x) Lifting lugs for complete transformer(xi)Top cover lifting lugs(xii) Jacking lugs(xiii) Top filter valve(xiv)Instruction plate(xv)Drain cum bottom filter valves(xvi)Earthing terminal and stud(xvii)Off load tap changer (xviii)Rating and Diagram plate(xix) Buchholz relay with alarm & trip contacts.(xx)Bi directional roller wheel -04 Nos. 69 (xxi)Marshalling box for termination of all alarm & trip controls of the transformer.(xxii)WTI (Winding temperature indicator) with alarm & trip contact(xxiii)Oil surge relay.(xxiv)Shut off valve for buchholz relay.(xxv) OTI (Oil temperature indicator) dial type of 150 mm with alarm and trip contact capillary type.(xxvi)Two earthing terminals on tank cover to facilitate fixing of 50x6 mm galvanised iron earth strip for earthing of body.(xxvii) Necessary PCC foundation/ block masonry platform as directed by OEM. (xxviii)First filling of new and unused transformer oil, IS-335 marked.Note 02 :- (a)The rates include for supplying transformers with standard fittings and installing complete including all jointing materials, connecting with electrical system, earthing, testing and commissioning. (b) The transformer will have its initial oil filling to appropriate level (cost of oil including testing with desired dielectric strength included in supplied and installed rates, cost of PCC foundation shall be included as per manufacturer drawing) 70 Supply, fixing, installing and commissioning of octagonal Galvanised street light pole 9 mtr long, top dia 70 mm, bottom dia 155 mm, sheet thickness 3 mm and base plate dimensions 260 x 260 x16 mm thickness with door locking arrangement for provision ofterminal plate consisting ofMCB TPN 10 Amps, with necessary electrical connections including 04 Nos foundation with J type foundation bolts -04 Nos of sizeas per manufacturer design should be hot dipped galvanized andGI single arm bracket (Ornamental type) complete with door locking arrangement complete all as specified and directed.Note:- Necessary Excavation of Soil, RCC foundation as per manufacture recommendation including foundation bolts etc deemed to be included in quoted rate. 71 Supply ,fabrication, installation and testing of LT Panel factory made, Type Test Assemble (TTA) Panel for working on 3 phase, 4 wire, 415 Volts, AC, 50Hz, cubical,Outdoor type, weather proof, water proof, dust proof, vermin proof, shock proof protectionmade out3.15 mm thick CRCA sheet of suiitable size accommodate accessories/ fittings with front and back double door opening/ lockable by the key from both side with IP 65 Protection and provn of suitable bus bar chamber and switch gear compartments for MCCB incoming & out going feeders etc with copper extension links of suitable curent carrying capacitty not less than 1.5 times the rated current carrying capacity of MCCB individual feeder supported on DMC/ Epoxy insulator including provison for termination with incoming and out going cables with cable glands. LT Panel shall be mounted on 50 x 50 x 6 mm size MS angle iron frame duly painted with two coats of black bituminus paint over a coat of red oxide primer including PCC foundation of suitable size with PCC 1:2:4 type B1(using 20 mm graded stone aggregate) .All extension link/ inter connection shall be insulated with heat shrinkable colour coaded sleeves to accomodate and including the following accessories:- (Transformer main LT Panel) 72 Note:- Rate of earthwork and PCC work etc are deemed to be inclusive in this item.IN COMING:a)Copper strip busbar of 1000 amps rated capaacity wrapped with PVC sleeves with maintained the colour code and provision of making holes with Copper nuts, bolts & washers for cable connections including hydrograpic insulators with nuts & bolts at both ends= 04 Nosb)4 pole MCCB 500 Amps with rotary handle, adjustable thermal magnetic release type 415 Volts,Ics = 100% Icu, breaking capacity 35 KA including all fixing accessories with both ends spreader links - 01 No.(c)LED Neon indicator lamp (RYB) with holder and fuse holder 230/250 volts, AC -01 set (set of three)Make :- Legrand/L&T/Schneider.(d)Digital Ammeter of range (0- 250) Amps, flush mounting type with CT’s of ratio 250/5 and selector switch – 01 set.(e)Digital voltmeter of range (0-500) volts, flush mounting type with selector switch – 01 No. 73 OUTGOING:- (a)4 Pole MCCB 125 Amps with rotaryhandle, adjustable thermal magnetic release type, 4 poles, 415 Volts, Ics = 100% Icu, 25 KA breaking capacity including all fixing accessories with both ends spreader links- 01 No (MWO/ WO accn Bldg Panel No 1)(b)4 Pole MCCB 160 Amps with rotaryhandle, adjustable thermal magnetic release type, 4 poles, 415 Volts, Ics = 100% Icu, 25 KA breaking capacity including all fixing accessories with both ends spreader links- 04 Nos (for Sgt Accn Panel No 2, 3, APFC panel & Spare)(c)4 Pole MCCB 32 Amps with rotaryhandle, adjustable thermal magnetic release type, 4 poles, 415 Volts, Ics = 100% Icu, 25 KA breaking capacity including all fixing accessories with both ends spreader links- 01 No(d)Enamelled iron danger notice plate of 1.60 mm thick mild steel sheet of size 200 mm X 150mm , white with letters , figures and conventional skull and bones in signal red and fixed with nuts and bolts on door / shutter - 01 No. 74 Supply ,fabrication, installation and testing of LT Panel factory made, Type Test Assemble (TTA) Panel for working on 3 phase, 4 wire, 415 Volts, AC, 50Hz, cubical,Outdoor type, weather proof, water proof, dust proof, vermin proof, shock proof protectionmade out3.15 mm thick CRCA sheet of suiitable size accommodate accessories/ fittings with front and back double door opening/ lockable by the key from both side with IP 65 Protection and provn of suitable bus bar chamber and switch gear compartments for MCCB incoming & out going feeders etc with copper extension links of suitable curent carrying capacitty not less than 1.5 times the rated current carrying capacity of MCCB individual feeder supported on DMC/ Epoxy insulator including provison for termination with incoming and out going cables with cable glands. LT Panel shall be mounted on 50 x 50 x 6 mm size MS angle iron frame duly painted with two coats of black bituminus paint over a coat of red oxide primer including PCC foundation of suitable size with PCC 1:2:4 type B1(using 20 mm graded stone aggregate) .All extension link/ inter connection shall be insulated with heat shrinkable colour coaded sleeves to accomodate and including the following accessories:- (forMWO/WO Accn LT Bldg Panel No1)Note:- Rate of earthwork and PCC work etc are deemed to be inclusive in this item. 75 IN COMING:-a)Copper strip busbar of 250 amps rated capaacity wrapped with PVC sleeves with maintained the colour code and provision of making holes with Copper nuts, bolts & washers for cable connections including hydrograpic insulators with nuts & bolts at both ends= 04 Nosb)4 pole MCCB 125 Amps with rotary handle, adjustable thermal magnetic release type 415 Volts,Ics = 100% Icu, breaking capacity 35 KA including all fixing accessories with both ends spreader links - 01 No.(c)LED Neon indicator lamp (RYB) with holder and fuse holder 230/250 volts, AC -01 set (set of three)Make :- Legrand/L&T/Schneider.(d)Digital Ammeter of range (0- 250) Amps, flush mounting type with CT’s of ratio 250/5 and selector switch – 01 set.(e)Digital voltmeter of range (0-500) volts, flush mounting type with selector switch – 01 No. 76 OUTGOING:- (a)4 Pole MCCB 63 Amps with rotaryhandle, adjustable thermal magnetic release type, 4 poles, 415 Volts, Ics = 100% Icu, 25 KA breaking capacity including all fixing accessories with both ends spreader links - 03 Nos (forMWO accn Bldg supply- 2 Nos & Spare)(b)4 Pole MCCB 32 Amps with rotaryhandle, adjustable thermal magnetic release type, 4 poles, 415 Volts, Ics = 100% Icu, 25 KA breaking capacity including all fixing accessories with both ends spreader links - 01 No (Street light)(c) Multifunctional Digial type Astronomical function Time switch (Astro type having longitude and latitude of Indian cities memory) 240 volts AC Single Phase - 01 No(d) Power contractor 4 Pole, 32 Amps,415 Volts, 50 Hz - 01 No (e)Enamelled iron danger notice plate of 1.60 mm thick mild steel sheet of size 200 mm X 150mm , white with letters , figures and conventional skull and bones in signal red and fixed with nuts and bolts on door / shutter - 01 No. 77 Supply ,fabrication, installation and testing of LT Panel factory made, Type Test Assemble (TTA) Panel for working on 3 phase, 4 wire, 415 Volts, AC, 50Hz, cubical,Outdoor type, weather proof, water proof, dust proof, vermin proof, shock proof protectionmade out3.15 mm thick CRCA sheet of suiitable size accommodate accessories/ fittings with front and back double door opening/ lockable by the key from both side with IP 65 Protection and provn of suitable bus bar chamber and switch gear compartments for MCCB incoming & out going feeders etc with copper extension links of suitable curent carrying capacitty not less than 1.5 times the rated current carrying capacity of MCCB individual feeder supported on DMC/ Epoxy insulator including provison for termination with incoming and out going cables with cable glands. LT Panel shall be mounted on 50 x 50 x 6 mm size MS angle iron frame duly painted with two coats of black bituminus paint over a coat of red oxide primer including PCC foundation of suitable size with PCC 1:2:4 type B1(using 20 mm graded stone aggregate) .All extension link/ inter connection shall be insulated with heat shrinkable colour coaded sleeves to accomodate and including the following accessories:-(for Sgt accn Bldg Panel No 2 & 3) 78 Note:- Rate of earthwork and PCC work etc are deemed to be inclusive in this item.IN COMING:- a)Copper strip busbar of 400 amps rated capaacity wrapped with PVC sleeves with maintained the colour code and provision of making holes with Copper nuts, bolts & washers for cable connections including hydrograpic insulators with nuts & bolts at both ends= 04 Nosb)4 pole MCCB 160 Amps with rotary handle, adjustable thermal magnetic release type 415 Volts,Ics = 100% Icu, breaking capacity 35 KA including all fixing accessories with both ends spreader links - 01 No.(c)LED Neon indicator lamp (RYB) with holder and fuse holder 230/250 volts, AC -01 set (set of three)Make :- Legrand/L&T/Schneider.(d)Digital Ammeter of range (0- 250) Amps, flush mounting type with CT’s of ratio 250/5 and selector switch – 01 set.(e)Digital voltmeter of range (0-500) volts, flush mounting type with selector switch – 01 No. 79 OUTGOING:- (a)4 Pole MCCB 100 Amps with rotaryhandle, adjustable thermal magnetic release type, 4 poles, 415 Volts, Ics = 100% Icu, 25 KA breaking capacity including all fixing accessories with both ends spreader links - 03 Nos ( Sgt Accn bldg supply- 02 Nos & Spare)(b)4 Pole MCCB 32 Amps with rotaryhandle, adjustable thermal magnetic release type, 4 poles, 415 Volts, Ics = 100% Icu, 25 KA breaking capacity including all fixing accessories with both ends spreader links - 01 No(e)Enamelled iron danger notice plate of 1.60 mm thick mild steel sheet of size 200 mm X 150mm , white with letters , figures and conventional skull and bones in signal red and fixed with nuts and bolts on door / shutter - 01 No. 80 Material and labourfor Boring of holes under road, pavement, hard standing by trenchless technology using ultra sound technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure for cable protection and making good as existing complete all as specified and as directed. 81 Material and labourfor maintenance free Chemical earthing of technology 3 mtr long20 mm dia with 250-micron Copper coating and UL listed. There should be terminal for connection of 150 x 50 x 6 mm with 4 holes of 12 mm dia along with 2 bags of 25 Kgs each of earth enhancing compound. The chemical compound should be tested and certified by any NABL accredited laboratory with 95 percent carbon content. The testing laboratory should be an ISO 9001 and 14001 certified. The earth enhancing compound should be IEC 62321. The ph value of compound should be 7-8. Electrode should be duly tested and certified by CPRI, Govt of India for a min short circuit current of 25 kA rms for 1 Sec. including necessary boring of suitable dia upto required depth in any type of soil for inserting copper rod and filling of chemicals and Poly plastic pit cover of material- polymer body & cover dimensions- 308 mm (L) x 308 mm (W) x 214 mm (H) bearing capacity 7.5 Ton approved from NABL approved Lab complete all as specified and as directed. 82 Note:- (i) Earthing is to be done infront of the Engr-in-Charge.(ii)Test Results of earthing to be submitted by the contractor for all earthings.(iii)The Contractor shall have to give written guarantee for maintenance earth resistance of less than 1.0 Ohm for the period of 10 9ten) years after certified date of completion and shall bdeposited 2000/- per earthing as security deposit for a period of Ten (10) Years.(iv)Failing to maintain resistance of earthing less than 1.0 ohm , new earthing to be provided by the contractor with out any extra cost.(v)Necessary earth work, excavation shall be carried out in any type of soil strata, retuning, filling in and making good surronding area complete. 83 EXTERNAL WATER SUPPLY 84 Supply, Laying, jointing & testing of 150mm dia (6) Ductile iron (DI), pressure pipes with spigot and socket ends, centrifugally cast, class K-7, with cement mortar lining in inner side as per IS:8329/ 2000 (latest revision) and other relevant standards and metallic zinc coating followed by a finishing layer ofepoxy paint in outer side,suitable for push on joint(rubber gasket joint) including rubber gasket in any length with inside cement mortar lining laid in trenches/ over masonry pillarcomplete all as specified and as directed 85 Supply, Laying, jointing & testing of 100mm dia (4) Ductile iron (DI), pressure pipes with spigot and socket ends, centrifugally cast, class K-7, with cement mortar lining in inner side as per IS:8329/ 2000 (latest revision) and other relevant standards and metallic zinc coating followed by a finishing layer ofepoxy paint in outer side,suitable for push on joint(rubber gasket joint) including rubber gasket in any length with inside cement mortar lining laid in trenches/ over masonry pillarcomplete all as specified and as directed.Notes foraboveItems No 53 & 54 :- (i) Excavation & Earthwork, shall be measured and paid separately. (ii) The necessary Exise duty exemption certificate from Deputy Commissioner of respective district shall be arranged by the GE for DI pipe.The contractor shall quote the rates against these items considering Exise exemption. (iii) The quoted rate shall also be deemed to include for provision of joints and jointing material for laying pipes. For jointing ofpipe fittings or taking branch connection, provision of joints and jointing material shall be measured and paid separately. (iv) . Before laying of pipe line contractor has to submit layout diagram as per level difference and ensure proper alignment of the pipe. 86 Material and Labour for Ductile iron fitting for spigot socket pipe such as bends (any type, radius and angle) tapers any type (straight, bend increasing, decreasing or double socket etc). Tee pieces single branch. Y junction, double branch, cross (All socket or socket and spigot) collars, restrained joint, mechanical joint, caps & plugs 80 mm to 250 mm dia bore including cutting and jointing new positions complete all as specified and as directed 87 Material and Labour forcutting CI pipes 150 / 80mm in position for insertion and including provision of Tee branches etcfor 80/50 mm dia pipe line complete all as specified and directed 88 Material and labour for construction of brick masonry valve pit of internal size 90cm x 90cm x 90cm suitable for gate valves/ sluice valve upto 150 mm including necessary excavation and earth work, brick work, plastering, white wash, PCC coping, MS frame made out of angle iron of size 50mmx50mmx6mm, MS sheet cover of 3 mm thick fixed to angle iron frame by means of hinges welded to frame and painting with 2 coats of synthetic enamel paint over a coat of red oxide primer on steel surfaces and grouting the frame in PCC 1:2:4 type B-1 including handle and locking arrangement with one number 50 mm dia brass pad lock complete all as specified and directed.Note:- (i) Brick wall shall be 23 cm thick built in cement mortar (1:6)(ii) Internal plaster shall be 15 mm thick in cement mortar (1:4) and external plaster upto 450 mm from top shall be 20 mm thick in CM (1:6) and remaining external surface shall be flush pointing in CM (1:6) as the work proceeds(iii) PCC in foundation shall be 15 cm thick in cement concrete (1:4:8) type D2 using 40 mm graded stone aggregate extended 15 cm all around from the external face of the walls (iv) PCC coping shall be 15 cm thick in cement concrete (1:2:4) type B1 using 20 mm graded stone aggregate including grouting of angle iron frame in PCC(v) Three coats of white wash to internal surfaces of valve pit shall be provided(vi) Depth of valve pit shall be reckoned from the top of PCC in foundation 89 Material and labour for construction of brick masonry valve pit of internal size 60cm x 60cm x 70cm suitable for gate valves/ sluice valve upto 150 mm including necessary excavation and earth work, brick work, plastering, white wash, PCC coping, MS frame made out of angle iron of size 40mmx40mmx6mm, MS sheet cover of 3 mm thick fixed to angle iron frame by means of hinges welded to frame and painting with 2 coats of synthetic enamel paint over a coat of red oxide primer on steel surfaces and grouting the frame in PCC 1:2:4 type B-1 including handle and locking arrangement with one number 50 mm dia brass pad lock complete all as specified and directed.Note:- (i) Brick wall shall be 23 cm thick built in cement mortar (1:6)(ii) Internal plaster shall be 15 mm thick in cement mortar (1:4) and external plaster upto 450 mm from top shall be 20 mm thick in CM (1:6) and remaining external surface shall be flush pointing in CM (1:6) as the work proceeds(iii) PCC in foundation shall be 15 cm thick in cement concrete (1:4:8) type D2 using 40 mm graded stone aggregate extended 15 cm all around from the external face of the walls (iv) PCC coping shall be 15 cm thick in cement concrete (1:2:4) type B1 using 20 mm graded stone aggregate including grouting of angle iron frame in PCC(v) Three coats of white wash to internal surfaces of valve pit shall be provided(vi) Depth of valve pit shall be reckoned from the top of PCC in foundation 90 RAIN WATER HARVESTING 91 Supply and Fixing 150mm bore PVC slotted pipes double socketed in any length with suitable joints, laid in bore hole for recharge pit and like complete all as specified and directed 92 Boring 300mm dia for Bored cast in situ piles 16 metres in any kind of soil/soft rock and getting out and disposal of spoil to a distance 50 metres using suitable method complete all as specified and directed 93 FIRE FIGHTING SYSTEM 94 Supply and Fixing for 3 kg light-weight squeeze grip CO2 type fire extinguisher, conforming to IS 15683: 2006, with CO2 gas filled in brand new seamless cylinder with powder coated finish, made out of Manganese steel with wheel type valve, discharge nozzle, bend & horn, wall mounting bracket / floor trolley mounting accessories along with suitable signage complete all as specified and directed Make: Kanex, Minimax, Aim-EX, Safeguard, Coffco, Variex 95 Supply and Fixing for 5 kg capacity dry chemical powder (ABC) type fire extinguisher, conforming to IS 15683: 2006, with initial filling in brand new cylinder with powder coated finish, fitted in gunmetal union, high pressure CO2 gas cartridge, discharge hose, wall mounting bracket / floor trolley mounting accessories along with suitable signage, etc. complete all as specified and directedMake: Kanex, Minimax, Aim-EX, Safeguard, Coffco, Variex 96 Supply and Fixing for 9 litre mechanical foam type fire extinguisher, conforming to IS 15683: 2006, with initial filling in brand new cylinder with powder coated finish, fitted with gunmetal union, high pressure CO2 gas cartridge, hose and ABS type branch pipe and wall mounting bracket / floor trolley mounting accessories along with suitable signage complete all as specified and directedMake: Kanex, Minimax, Aim-EX, Safeguard, Coffco, Variex 97 Supply and Fixing for 9 kg capacity dry chemical powder (ABC) type fire extinguisher, conforming to IS 15683: 2006, with initial filling in brand new cylinder with powder coated finish, fitted in gunmetal union, high pressure CO2 gas cartridge, discharge hose, wall mounting bracket / floor trolley mounting accessories along with suitable signage, etc. complete all as specified and directedMake: Kanex, Minimax, Aim-EX, Safeguard, Coffco, Variex 98 Supply and Fixing for Galvanized mild steel Fire bucket (Filled with dry sand & water) conforming to IS 2546: 1974 round bottom type enamel painted, white inside & Red out side and Letter FIRE in black out side and handle with mounting bracket complete as specified and directed 99 Supply and Fixing for Galvanized mild steel Fire hook bracket with 3 mtr bamboo handle painted with red colourcomplete as specified and directed 100 Supply and Fixing for Galvanized mild steel Fire Beater bracket with 3 mtr bamboo handle painted with red colourcomplete as specified and directed
Contract Date: Mar 11, 2026 Contract Value : 14.98 Crore
Statutory Bodies & Commissions/Committees No of Bidders 5
12.
Agriculture #9685449 Price Bid
Tender For Annual Plan 2025-26- Support To Farm Mechanisation Establishment Of Farm Machinery Clinic- Purchase Of Tools And Equipments For Agri Clinic At Chc Kozha , Hand Tools , A) Screwdriver Bits (26 Pcs, 25 Mm Length, S2 Steel) B) Phillips (Ph): Ph0, Ph1, Ph2, Ph3 C) Pozidriv (Pz): Pz0, Pz1, Pz2, Pz3 D) Slotted (Sl): Sl4, Sl5.5, Sl7 E) Hex (H): H2, H3, H4, H5, H6, H7, H8, H10 F) Torx (T): T10h, T15h, T20h, T25h, T27h, T30h, T40h G) Bit Holder (1 Pc) - 1/4 Hex H) Hexagonal Sockets (9 Pcs) - Sizes: 4, 4.5, 5, 5.5, 6, 7, 8, 9, 10 Mm I) Star Sockets (5 Pcs) - Sizes: E4, E5, E6, E7, E8 J) Ratchet Wrench (1 Pc) - 1/4 Drive, 45 Teeth (Reversible) K) Extension Bars (3 Pcs) - Lengths: 50 Mm (2), 100 Mm (4), 150 Mm (6) L) Universal Joint (1 Pc) - 1/4 Drive M) Three-Way Adaptor (1 Pc) - 3/8 Female × 1/4 Male N) Spinner Handle (1 Pc) - 1/4 × 150 Mm O) Flexible Extension Bar (1 Pc) - 1/4 × 150 Mm 4. Combination Spanners (17 Pcs) - Sizes: 6, To 24 Mm 5. Flare Nut Spanners (5 Pcs) - Sizes: 8×10, 10×12, 11×13, 12×14, 17×19 Mm 6. Hex Key Set (10 Pcs) - Sizes: 2.5, 3, 4, 5, 6, 7, 8, 10, 12, 14 Mm 7. Machinist Hammer (1 Pc) - 300 G With Fiberglass Or Wooden Handle 8. Combination Pliers (1 Pc) - 7 9. Locking Pliers (1 Pc) - 10 Curved Jaw Lock Wrench 10. Slotted Screwdrivers (2 Pcs) - Sl6.5 × 100 Mm And Sl6.5 × 150 Mm 11. Phillips Screwdrivers (2 Pcs) - Ph2 × 100 Mm And Ph2 × 150 Mm 12. Stubby Screwdrivers (2 Pcs) - Ph2 × 38 Mm And Sl6.5 × 38 Mm All Sockets, Spanners, And Ratchets Shall Be Made From Chrome Vanadium Steel (Cr-V), Heat-Treated, And Chrome-Plated For Corrosion Resistance. Screwdriver Bits Shall Be Of S2 Alloy Steel For High Torque Resistance. Ratchets Shall Have A Minimum Of 45 Teeth With A Quick-Release And Reversible Mechanism. All Tools Shall Conform To Din / Iso Standards Or Equivalent. Suitcase Colour Should Be Standard Industrial Colour (Black / Blue / Grey Or Similar) , Tee Spanner Set Including Spanners Ranging From 8 Mm To 19 Mm Made From Chrome Vanadium Steel (Cr-V), Hardened And Tempered For Durability, The Handle Shall Be T-Shaped, Providing Maximum Torque And Grip And Surface Finish Shall Be Nickel-Chrome Plated For Corrosion Resistance. , Deep Socket Set Consist Of Sockets From 8 Mm To 22 Mm, Made Of Chrome Vanadium Steel, Fully Hardened, Tempered, And Chrome-Plated, The Sockets Shall Have Six-Point Or Twelve-Point Configurations For High Torque Applications, Suitable For Use With Ratchet Handles And Extension Bars. , Combination Plier 6 Manufactured From High-Grade Alloy Steel, With Precision Machined Jaws, Cutting Edges Induction-Hardened For Long Life. Handles Shall Be Double-Dipped With Insulated Grips For Comfort And Safety. , Combination Plier 8 Manufactured From High-Grade Alloy Steel, With Precision Machined Jaws, Cutting Edges Induction-Hardened For Long Life. Handles Shall Be Double-Dipped With Insulated Grips For Comfort And Safety. , Circlip Plier Internal 7 Made Of High-Grade Alloy Steel, With Spring-Loaded Return And Polished Tips For Easy Installation And Removal Of Internal Retaining Rings, Handle Grips Shall Be Pvc Or Rubber-Coated. , Circlip Plier External 7 Made Of High-Grade Alloy Steel, With Spring-Loaded Return And Polished Tips For Easy Installation And Removal Of Internal Retaining Rings, Handle Grips Shall Be Pvc Or Rubber-Coated. , Locking Plier (Vice Grip Type) 10 With Drop-Forged Steel Jaws With Heat-Treated Teeth For Firm Gripping, Include An Adjustable Screw And Quick-Release Lever, Nickel-Plated Surface For Corrosion Protection. , Diagonal Cutting Pliers, 6, Made Of Forged Alloy Steel, With Induction-Hardened Cutting Edges And Insulated Handles Suitable For Cutting Wires And Small Metal Parts. , Long Nose Plier 6 Made Of Forged Alloy Steel With Slim Tapered Jaws For Precision Gripping And Cutting In Confined Spaces, 6 Overall Length, With Insulated Handles. , Long Nose Plier 8 Made Of Forged Alloy Steel With Slim Tapered Jaws For Precision Gripping And Cutting In Confined Spaces, 8 Overall Length, With Insulated Handles. , Adjustable Pipe Wrench Suitable For Gripping Pipes Up To 40 Mm Diameter Made Of Cast Iron Body With Drop-Forged Steel Jaws, Serrated And Induction-Hardened And Handle Painted Or Powder-Coated. , Adjustable Pipe Wrench Suitable For Gripping Pipes Up To 75 Mm Diameter Made Of Cast Iron Body With Drop-Forged Steel Jaws, Serrated And Induction-Hardened And Handle Painted Or Powder-Coated. , Heavy-Duty Pipe Wrench With Jaw Opening Up To 110 Mm Made Of Forged Alloy Steel, Precision-Machined Teeth For Firm Grip, Designed For Mechanical And Plumbing Use. , Heavy-Duty Filter Wrench With High-Tensile Rubber Or Nylon Strap And Steel Handle For Removing Large Oil/Fuel Filters, Handle Length: Minimum 300 Mm. Suitable For Heavy Machinery Maintenance. , Medium-Duty Filter Wrench With Adjustable Steel Band And Handle, Suitable For Medium-Sized Oil Filters. Chrome-Plated Finish With Non-Slip Grip. , Ball Pein Hammer With 300 Gm Forged Steel Head, Hardened And Tempered. Fitted With A Strong Fiberglass Handle Suitable For Riveting, Striking, And Metal Forming. , Soft Face Hammer With Dual Rubber Striking Faces To Prevent Surface Damage. Head Weight Approx. 300-500 Gm, Handle Made Of Fiberglass , Non-Marring Mallet Hammer With Rubber Or Plastic Head 40 Mm And Sturdy Handle. Head Weight Approx. 1 Kg. Suitable For Precision Fitting Without Metal Deformation. , Sledge Hammer With 500 Gm (2 Lb) Drop-Forged Steel Head, Hardened And Tempered. Handle Of Strong Wooden Or Fiberglass Construction, Securely Fixed To Head. , Cold Chisels Made Of Chrome Vanadium Or Carbon Steel (18 Mm Dia Approax) , Hardened And Tempered To 58-60 Hrc. Size 25 Mm, Length 300 Mm, Approax Weight 500 Gm Ground Cutting Edge With Anti-Slip Striking End. , Steel Wedges, Hardened And Ground, Used For Splitting Or Aligning. Made Of Forged Alloy Steel With A Rust-Resistant Finish 230 Mm Length 1.5 Kg. , Adjustable Torque Wrench With Working Range 25-135 Nm. Drive Size 3/8 Or 1/2, Accuracy ±4% Of Indicated Value With Reversible Ratchet And Quick-Release Mechanism. , Heavy-Duty Adjustable Torque Wrench, Range 70-340 Nm. 1/2 Drive, Accuracy ±4%, Chrome Vanadium Construction With Calibration Certificate. , High-Capacity Torque Wrench, Range 135-540 Nm. 3/4 Drive, Accuracy ±4%, Knurled Handle For Non-Slip Grip, Supplied With Protective Case And Calibration Certificate. , Measuring Tools , Steel Scale Set (5 Nos) Made Of High-Quality Tempered Stainless Steel With Etched And Permanently Engraved Graduations In Both Metric (Mm/Cm) And Inch Units. Straight, With Accurately Ground Edges And Smooth Surfaces, Graduation Accuracy Shall Conform To Is 1481:1970 Or Equivalent. Lengths : 150 Mm, 300 Mm, 600 Mm, 450 Mm, 1000 Mm. Each Scale Shall Have Clear Visibility Markings And Corrosion-Resistant Satin Chrome Finish. , Vernier Calipers Made Of Stainless Steel, Precision-Ground And Finished, With A Measuring Range Of 0-200 Mm And Least Count 0.02 Mm / 0.001 Inch Capable Of Internal, External, Depth, And Step Measurements. Vernier Scale And Main Scale Markings Shall Be Clearly Etched For Long-Term Readability. The Instrument Shall Conform To Is 3651:1981 Or Din 862 Standards. A Locking Screw Shall Be Provided For Measurement Retention, And The Tool Shall Be Supplied In A Protective Case. , Outside Micrometer (0-25 Mm Range) Of Mechanical Analog Type, Conforming To Is 2967:1975 Or Din 863 Standards. The Frame Shall Be Rigid And Heat-Insulated, With Carbide-Tipped Measuring Faces, A Friction Thimble, And A Ratchet Stop For Consistent Measuring Pressure. The Least Count Shall Be 0.01 Mm, And The Thimble And Sleeve Shall Have Clearly Graduated Markings. The Micrometer Shall Be Supplied With A Setting Standard And Calibration Certificate. , Outside Micrometer (25-50 Mm Range) Of Mechanical Analog Type, Conforming To Is 2967:1975 Or Din 863 Standards. The Frame Shall Be Rigid And Heat-Insulated, With Carbide-Tipped Measuring Faces, A Friction Thimble, And A Ratchet Stop For Consistent Measuring Pressure. The Least Count Shall Be 0.01 Mm, And The Thimble And Sleeve Shall Have Clearly Graduated Markings. The Micrometer Shall Be Supplied With A Setting Standard And Calibration Certificate. , Feeler Gauges Made Of Hardened And Tempered Spring Steel, Precision-Ground To Required Thickness, And Permanently Marked With Size Values. The Set Shall Include Multiple 75 Mm Long Blades Of 30 Different Thicknesses 0.03 Mm To 1.00 Mm Assembled In A Steel Holder With Pivot. Each Blade Shall Be Rust-Resistant And Polished For Smooth Operation. The Gauge Shall Conform To Is 3179:1982 Or Equivalent Standards. , Wire Gauge (Standard Bs 1505 Type) Manufactured From Hardened And Tempered Steel With Precisely Cut Slots For Wire Sizes 1 To 36 Swg. The Gauge Shall Be Circular Or Rectangular In Shape With Permanent Engraved Markings. The Tool Shall Comply With Bs 3737 / Is 3177 Standards For Accuracy. Surface Shall Be Satin Chrome Or Nickel Plated To Resist Corrosion Suitable For Measuring Diameters Of Wires, Rods, And Drill Bits. , Inside Calipers Shall Be Made Of Forged Steel Or Stainless Steel, Polished And Hardened. The Legs Shall Have Finely Ground Points With A Pivot Joint And Tension Adjustment For Smooth Movement. Measuring Range: 20-170 Mm Suitable For Measuring Internal Dimensions And Bore Diameters. Shall Conform To Is 3564:1985 Standards. , Outside Calipers Made Of High-Grade Carbon Or Stainless Steel With Hardened Tips, Spring Joint, And Knurled Adjustment Nut For Precision. Shall Conform To Is 3564:1985 Or Equivalent Standards. Surface Finish: Polished Or Chrome-Plated. 12 Inch Size , Centre Punch Manufactured As Per Is 7177 - 1999 Or Equivalent, Made Of High Carbon Or Alloy Tool Steel, Hardened And Tempered At The Striking End And Point. Length: Approximately 150 Mm, Approximate Weight 160 Gm With Point Angle Of 60° ± 2°. The Striking End Shall Be Chamfered To Prevent Mushrooming. Surface Finish Shall Be Black Oxide Or Polished. Suitable For Marking Centers On Metal Surfaces Before Drilling Operations. , Portable Digital Non-Contact Tachometer Of Reputed Make, With A Non-Contact Measuring Range Of Approximately 10 To 99,999 Rpm And Accuracy Not Inferior To ±0.04% ±2 Digits. Equipped With A Digital Lcd Display, Data Hold, Counting Function, And Computer/Usb Interface For Data Transfer, A Working Distance Of Around 0.2 M With A ±30° Working Angle, Reflective Tape, Interface Cable, And Carrying Case. Conforming To Iec 61010-1 / Is 13875. , Auto Electrial And Pump , Portable True-Rms Digital Multimeter Of High-Accuracy, Capable Of Measuring Ac/Dc Voltage Up To 1000 V, Ac/Dc Current Up To 10 A, Resistance, Capacitance, Frequency, Diode, And Continuity. The Meter Should Have Features Like Auto-Ranging, Data-Hold, Min/Max, And Relative Measurement Functions With A Large Back-Lit Display Of Minimum 4000 Counts Or Higher. The Instrument Shall Have Overload Protection, Fused Input Terminals, And Comply With Safety Category Cat Iii 1000 V Or Cat Iv 600 V As Per Iec 61010-1. The Unit Shall Be Housed In A Protective Insulated Casing Suitable For Field Use And Supplied Complete With Test Leads, Batteries, Protective Case, And Calibration Certificate. , Handheld Clamp Meter (True-Rms Type) Designed For Measurement Of Ac And Dc Currents Up To 1000 A, With Additional Functions For Ac/Dc Voltage, Resistance, Frequency, And Continuity. The Jaw Opening Shall Accommodate Conductors Up To 40-60 Mm In Diameter. The Meter Shall Feature A Large Digital Display, Auto-Range Selection, Data-Hold And Peak Capture Functions, And Have An Accuracy Of ±2 % Or Better. It Shall Meet Cat Iii 1000 V / Cat Iv 600 V Safety Standards, Include Overload And Transient Protection, And Be Built In A Shock-Resistant Insulated Body. The Clamp Meter Shall Be Supplied With Test Leads, Carrying Pouch, And Calibration Certificate. , Handheld Vibration Meter Shall Be Capable Of Measuring Vibration Velocity, Displacement, And Acceleration Within A Frequency Range Of 10 Hz To 1 Khz Or Higher Complying Iso 2954. The Instrument Shall Display Rms Or Peak Values In Standard Engineering Units (Mm/S, ?M, M/S²). It Shall Feature A Detachable Accelerometer Probe, Communicate With Pc Computer For Statistics And Printing By The Optional Cable And The Software. The Device Shall Be Compact, Battery-Operated, And Suitable For Predictive Maintenance Of Rotating Machinery. It Shall Be Supplied With Transducer, Magnetic Base, Extension Cable, And Carrying Case. , Wire Strippers Suitable For Removing Insulation From Copper Conductors Ranging From 0.5 Mm² To 6 Mm² , Ratchet-Type Crimping Tool Designed For Insulated And Non-Insulated Terminals 1.5 Mm² To 10 Mm², With Interchangeable Dies And Ergonomic Handles.Alloy Steel Duly Hardened & Tempered , Heavy-Duty Mechanical Or Ratchet Type Cable Cutters Suitable For Cutting Copper And Aluminium Cables Up To 300 Mm² , Soldering Iron Shall Be Of 40 W Capacity Insulated Handle. Cable Lugs And Ferrules Shall Be Of Tinned Copper, Crimp Type, Conforming To Din 46234/46235 Standards , Infrared Thermometer (Ir Gun) Shall Measure From -50 °C To +550 °C With Laser Targeting And Digital Display. Should Have Rugged, Insulated Housings And Be Supplied With Charger, Carry Case, And Calibration Certificate. , Battery Load Tester (12V) Shall Provide Controlled Load Up To 2-200 Ah To Assess Battery Condition By Measuring Voltage Drop And Internal Resistance Instruments Shall Have Clear Displays, Polarity Protection, Insulated Clamps, And Rugged Enclosures For Workshop Use. , Smart Battery Charger Shall Provide Automatic Multi-Stage Charging For 12 V Batteries With Protections For Overcharge And Polarity Reversal. , Tractor And Automobile , Manual Engine Stand Fabricated From High-Strength Heavy-Duty Mild Steel Tubular Sections, Finished With Powder Coating For Corrosion Resistance And Durability With A Lifting Capacity Of 2000 Lbs (Approximately 900 Kg), A Manual Locking Mechanism For Secure Positioning, And Four Swivel Casters For Easy Mobility And Stability. The Equipment Shall Conform To The General Safety And Design Provisions Of Is 8610:1977 (Automobile Service Equipment - Engine Stand) Or Equivalent International Standards, Ensuring Mechanical Stability, Ease Of Rotation, And Operator Safety. , Spring Compressor - Head Valve Type, Of Reputed Make Made Of High-Strength Carbon Steel With A Corrosion-Resistant Finish, Having An Overall Length Of Approximately 750 Mm And Weight Around 700 G Conforming To Relevant Standards For Hand Tools Such As Is 5781 / Is 6131 / Iso 6787 Or Equivalent. , Piston Ring Compressor (Set Of 3) Of Reputed Make, Made Of Hardened And Tempered Alloy Or Carbon Steel With A Polished Or Chrome-Plated Corrosion-Resistant Finish, And Provided With A Ratchet Or Key-Type Locking Mechanism For Uniform Compression And Easy Releasewith An Adjustable Diameter Range Suitable For Standard Engine Pistons (50 Mm To 125 Mm With 75 Mm Height, 90 Mm To 175 Mm With 100 Mm Height, And 90 Mm To 175 Mm With 150 Mm Height), Conforming To Relevant Standards Such As Is 7347 / Iso 1174 To Be Supplied Complete With Necessary Tightening Wrench Or Handle. , Portable Diesel Injector Nozzle Pop Tester, With A Dual-Scale Pressure Gauge (0-400 Bar / 0-6000 Psi), A Manual Hydraulic System With An Oil Cup Capacity Of 0.8 Litres, Constructed From High-Grade Plastic, And A Rugged Metallic Pump Body, Approximate Weight Of 4.25 Kg, Conforms To Iso 4113 (Calibration Fluid For Diesel Injection Equipment) And Iso 4008-1 / Iso 4008-2 (Diesel Fuel Injection Test Equipment - Testing Of Injection Pumps And Injectors). , Injector Puller Set (8 Pcs), Including Eight Precision-Engineered Oxidized Carbon Steel Components Comprising An Inertia Hammer, A Joint For Accessing Hard-To-Reach Areas, And Six Threaded Adapters With Sizes M12×1.75, M17×1, And M27×1, Ensuring Compatibility With Injectors From Major Manufacturers, Hammer Length Of 350 Mm All Conforms To Iso 6789:2017 (Torque Tools - Requirements And Test Methods) And Din 3122 (Hand-Operated Tools For Mechanical Drive). , Mechanical Puller (3?, 2/3-Jaw, Double Ended) Of Reputed Make Made Of Hardened And Tempered Alloy Or Carbon Steel And Finished With Corrosion-Resistant Coating, With Interchangeable 2-Jaw And 3-Jaw Configuration, Allowing Both Internal And External Gripping Applications, Nominal Jaw Size Shall Be 3 Inch (76.2 Mm), With A Spread Of Approximately 76 Mm, Reach Of About 65 Mm, And Working Diameter Range From 15 Mm To 80 Mm, Threaded Spindle Length 125 Mm, Conforming To Is 6149 / Iso 2985 Standards. , Mechanical Puller (8?, 2/3-Jaw, Double Ended) Of Reputed Make Made Of Hardened And Tempered Alloy Or Carbon Steel And Finished With Corrosion-Resistant Coating, With Interchangeable 2-Jaw And 3-Jaw Configuration, Allowing Both Internal And External Gripping Applications, Nominal Jaw Size Shall Be 8 Inch (203.2 Mm), With A Spread Of Approximately 203 Mm, Reach Of About 177 Mm, And Working Diameter Range From 30 Mm To 210 Mm, Threaded Spindle Length 174 Mm, Conforming To Is 6149 / Iso 2985 Standards. , Clutch Alignment Tool Of Reputed Make, Made Of Durable Carbon Steel, Resistant To Wear And Corrosion, And Capable Of Withstanding Repeated Workshop Use. The Tool Shall Be Adjustable Or Provided In A Set To Suit Various Pilot Bearing And Clutch Plate Diameters (Approximately 14 Mm To 28 Mm Or Equivalent Range), Conforming To Is 7347 / Iso 1174 Or Equivalent For Hand Tools, , Valve Seat & Face Cutter Set Of Seat Cutters, Face Cutters, Arbors, And Pilots (20 Nos) Of High-Grade Alloy Steel With Precision-Ground Cutting Edges, Hardened And Tempered To Maintain Cutting Efficiency, Conforms To Is 5517:1993 (Specification For Cutting Tools - General Requirements) And Iso 513 (Classification And Application Of Cutting Tool Materials) , T-Handle Spark Plug Socket Wrench (21 Mm) Carbon Steel With A Chrome-Plated Finish, With A 360-Degree Swivel Head For Flexible Operation, A Plastic Grip On The T-Handle, A Rubber Insert Within The Socket, An Approximate Weight Of 110 Grams, And Conforming To Relevant Standards For Hand Tools. , 10Pcs Carburetor Adjusting Tool Kit Including: 21-Teeth Splined, 7-Teeth Splined, Single D, Small Head Single D, Double D, Pac Man, Small Head Pac Ma,N Hexagon Shaped, Six Star, And Carburetor Cleaning Tools All Made Of High-Quality Stainless Steel Wear Resistant And Long Lasting With Ergonomic Handle Comfortable To Grip And Stable To Use. , The Heavy-Duty Spark Plug Cleaner And Tester Designed To Clean And Test Spark Plugs Under Simulated Engine Conditions, Operates On A 220 V Ac Supply And Incorporates A 12 V / 12 Kv Ignition Coil For Spark Generation And A 220 V / 12 V Electronic Vibrator For Cleaning Including A Pressurized Testing Chamber With A Working Pressure Of Up To 12 Kgf/Cm² And A Separate Abrasive Cleaning Chamber Equipped With A Double-Acting Valve For Blasting And Dust Removal, Should Be Compatible With Spark Plug Sizes M10, M12, M14, And M18 Through Interchangeable Rubber Adapters And Features A Pressure Regulator For Maintaining Safe And Consistent Operation. Product Should Conform To General Standards For Electrical Safety And Workshop Equipment, Such As Is 302 (Part 1): Safety Of Electrical Equipment, Is 10326: Automotive Service Equipment - Spark Plug Testers, Or Equivalent International Standards , Portable Fuel And Vacuum Gauge Tester Kit For Testing Fuel Pump Pressure, Fuel Pump Vacuum, Carburettor Intake, And Manifold Vacuum Systems In Petrol Engines With Dual Gauges - A Pressure Gauge Ranging From 0 To 10 Psi (0-0.7 Kg/Cm²) And A Vacuum Gauge Ranging From 0 To 28 In-Hg (0-70 Cm-Hg) - For Accurate Measurement Of Engine Fuel And Air System Performance, With Standard Automotive Fittings For Quick Connection To Various Fuel And Vacuum Lines And Conforming To Is 1446: Automotive Test Equipment - Pressure And Vacuum Gauges Or Equivalent International Standards Like Sae J1812 For Fuel System Testing Instruments. , Petrol Engine Compression Tester Kit (400 Mm) Including Threaded Adaptors In Sizes M10, M12, M14, And M18, Along With Two Rubber Cone Ends For Both Threaded And Non-Threaded Testing, Equipped With Straight And Angled Push-On Connectors And A 400 Mm Flexible Hose, To Diagnose Issues Related To Piston Rings, Valves, Or Head Gaskets, Suitable For Cars, Motorcycles, And Small Petrol Engines. , Heavy-Duty Sprocket Chain Breaker And Splitter Tool Suitable For Breaking, Splitting, And Repairing Chains Of Size 420 To 530 Made Of High-Grade Carbon Steel , Compact Chain Saw Grinder For Precise Grinding Of Chain Saw Blades For A Rated Voltage Of 220-230 V At 50/60 Hz, With An Input Power Of 300 W And A No-Load Speed Of 8400 Rpm, Equipped With A 100 Mm Grinding Wheel Suitable For Most Standard Chain Saw Chains, Weighing Around 2.5 Kg, Conforming To General Safety And Performance Standards Such As Is 302 (Part 2/Sec 201): Electrical Safety For Hand-Held Tools And Iec 60745-2-4 , Soldering Station Operating On A 220-240 V Ac, 50/60 Hz Supply, Input Power Of 60 W, With A Preheat Time Of Approximately 1 Minute, Digital Temperature Display, Adjustable And Thermostatic Temperature Control Via A Rotary Knob, Built-In Ceramic Heating Element, A Straight Tip Head, A Durable Stand For Iron Placement, Packed In A Color Box, Conforms To Iec 60335-2-45: Household And Similar Electrical Appliances - Safety Of Portable Heating Tools And Iec 61340-5-1: Protection Of Electronic Devices . , Compact, Durable, And Easy To Operate Portable High-Pressure Hand-Operated Portable Grease Pump With A 10 Kg Grease Capacity And Delivers A Material Output Of Approximately 3 Grams Per Stroke, Maximum Block Pressure Of 140 Kg/Cm², A 2-Meter High-Pressure Rubber Hose Fitted With End Connections. , Double Piston Lever Grease Gun Delivering Up To 2.4 Grams Of Grease Per Stroke, Pressures Up To 6000 Psi, With A Double-Piston Mechanism, Compact And Lightweight (Approx. 2 Kg). , Durable And Easy-To-Use Steel Lubrication Oil Dispenser Can For Smooth And Controlled Lubrication With A 500 Ml Capacity, Made From High-Quality Steel With A Powder-Coated Finish, The Can Is Lightweight (Approx. 200 G), Waterproof, And Ergonomically Designed For Comfortable Handling And Precise Oil Flow. , Power Tools And Equipment , Corded Type Electric Impact Wrench Conforming To Is 7151:1983 / Iec 60745-2-2 [Vibration (=11.5 M/S²), And Noise (104 Db(A))], With A Continuous Input Rating Of 400 W,. It Shall Provide A Maximum Fastening Torque Of 350 N·M, With A No-Load Speed Of 2000 Rpm And Impact Rate Of 2000 Blows Per Minute, 12.7 Mm (½) Square Drive, A 2.5 M Power Supply Cord. The Housing In Impact-Resistant Polymer With Reinforced Internal Metal Gear Casing, Suitable For Tightening And Loosening Ensuring Efficient Operation For Both Standard (M12-M22) And High-Strength Bolts (M12-M16) In Vehicle And Machinery Maintenance Applications , Heavy-Duty Angle Grinder, Of Reputed Make, Single Phase 220-240 V, 50/60 Hz Ac Supply, Input Power 2200 W No-Load Speed 8500 Rpm To Use With 180 Mm (7) Diameter Abrasive Wheels, And Equipped With Side Handle, Wheel Guard, And Spindle Lock A 2.0 M Power Supply Cord And Conforming To Is 7554 / Iec 60745-2-3 / Iso 11148-7 Or Equivalent Standards (Low Vibration Level (=6.5 M/S²), Sound Pressure Level Not Exceeding 91 Db(A)). , Electric Power Drill (Corded Type) Of Reputed Make, Single Phase 220-240 V, 50 Hz Ac Supply, 350 W And Variable Speed Range Up To 3000 Rpm (No Load). Including A Pistol-Grip Body, Keyed Or Keyless Chuck, And A 2.0 M Power Supply Cord Complying With Is 7554 / Iec 60745 / Iso 11148 Or Equivalent Standards, [Low Vibration (=3.0 M/S²) And Sound Pressure Level Below 80 Db(A)] Supplied Complete With Chuck Key, Side Handle (If Applicable), And Instruction Manual. , Portable Electric Heat Gun Powered By An 1800 W Motor Operating At 230 V Ac, For Adjustable Airflow Between 350-550 L/Min And A Working Temperature Range Of 60°C To 550°C, Selectable In Three Stages (60/350/550°C), Achieves Full Heat-Up Within 1 Minute, With A Heat-Resistant Plastic Body And Heat Isolation Cap, Weighs 750 G And Features A 2 M Cord Length And Conforming To Iec 60335-2-45: Household And Similar Electrical Appliances - Safety Of Portable Heating Tools And Iec 61000-3-11/12: Electromagnetic Compatibility Standards. , Portable Air Compressor, Of Reputed Make, Single Phase 230 V, 50 Hz Ac Supply, Fitted With An Electric Motor Of 2.0 Hp (1.5 Kw) A Maximum Working Pressure Of 8 Bar, Free Air Delivery Not Less Than 200 Lpm (7.2 Cfm), And A Motor Speed Of 2850 Rpm. Air Receiver Tank Of 50 Liters Capacity, Conforming To Is 5456 / Is 2825 Standards And The Compressor Shall Conform To Is 10437 / Iso 1217, And Fitted With Pressure Gauge, Safety Valve, Drain Valve, And Automatic Pressure Switch. The Complete Unit Shall Be Portable, Vibration-Damped, And Equipped With Wheels And Handle For Easy Movement. , Single Phase Annual Rate Contract Welding Machine Of Reputed Make, With Inverter-Based Igbt Technology To Be Operated On Ac 220V ±15%, 50/60 Hz Single Phase Supply And Deliver A Welding Output Current Up To 400 Annual Periodical Maintenance With A Duty Cycle Of Not Less Than 60%, An Efficiency Of Minimum 80% And Power Factor Not Less Than 0.73, With Insulation Class F And Protection Grade Ip21 As Per Is 2879 / Is 3024 Or Equivalent International Standards. And Necessary Accessories Such As Welding Cable, Electrode Holder, And Earth Clamp Etc. Should Be Included. , Mig (Metal Inert Gas) Welding Machine Of Reputed Make, Operate On Single Phase Ac 220V ±15%, 50/60 Hz Having An Output Current Range Of 20-300 Annual Periodical Maintenance With A Duty Cycle Not Less Than 60%, No-Load Voltage Of Approximately 60 V Rated Input Current Of About 19.8 A, Power Factor Not Less Than 0.93, Efficiency Of At Least 85%, Housing Protection Shall Be Minimum Ip21 Conforming To Class F, And, As Per Is 10178 / Is 2879 / Is 3024 , Bench Grinder, Of Reputed Make, Single Phase 220-240 V, 50 Hz Ac Supply Equipped With A 350 W Induction Motor Of 2950 Rpm. Two 200 Mm Diameter Grinding Wheels Each Provided With Eye Shields And Wheel Guards, Heavy-Duty Aluminum Base With Tool Rest, Tool Storage Box, And Safety Accessories Etc. Complete Conforming To Is 302 / Is 6932 / Iec 61029 Or Equivalent. , Furniture And General , Bench Vice Of Heavy-Duty Engineers Type, Suitable For Fitting And General Workshop Applications With Jaw Width 125 Mm (5 Inches), With Replaceable Serrated Hardened Steel Jaws For A Firm Grip On Workpieces, The Body And Sliding Jaw Shall Be Made From High-Grade Cast Iron Or Forged Steel, Precision Machined To Ensure Smooth Operation And Alignment. The Vice Shall Be Equipped With A Large-Diameter Acme-Threaded Spindle And Steel Handle With Knurled Ends For Easy Tightening (1600 Kg Tightening Force) And Release. The Vice Includes A 360° Swivel Base With Locking Mechanism, Allowing Positioning And Adjustment As Required During Work. The Anvil Surface On The Rear Shall Be Machined And Hardened, Suitable For Light Hammering Operations. The Vice Shall Have A Clamping Capacity Of At Least 150 Mm, And All Moving Parts Shall Be Protected Against Rust And Corrosion By Paint Or Plating. The Bench Vice Should Be Suitable For Mounting On Heavy-Duty Wooden Or Steel Workbenches And Capable Of Withstanding Heavy Mechanical Use In Workshops And Maintenance Facilities. It Shall Conform To Is: 2586 (Specification For Bench Vices, Heavy Duty) Or Equivalent Standard. , Removable And Corrosion-Resistant Drip Tray Of Size 1200 Mm (L) × 600 Mm (W) × 40 Mm (H) Fabricated From Galvanized Steel Sheet Of Minimum 1.6 Mm Thickness Or 304-Grade Stainless Steel, Ensuring Long Service Life And Resistance To Rust And Chemical Attack, Suitable To Collect Oil, Fuel, And Coolant Spills During Small Engine Maintenance Operations. The Edges Should Be Folded And Reinforced To Prevent Deformation And Improve Rigidity, The Corners Shall Be Welded And Leak-Proof, And The Base Shall Be Slightly Inclined (1-2° Slope) To Facilitate Drainage. It Should Include A Removable Drain Plug Or Outlet Provision (½ Bsp) For Easy Cleaning And Disposal Of Collected Fluids. The Surface Shall Be Smooth, Easy To Clean, And Oil-Resistant, Suitable For Workshop Environments Handling Petrol And Diesel Engines. , Heavy-Duty Roller Tool Cabinet With 4 Drawers And One Cupboard Suitable For Use In Mechanical, Workshops For Organized Storage Of Hand Tools, Instruments, And Accessories Made Of High-Quality Cold-Rolled Steel Sheet With A Cabinet Body Thickness Of 0.8-1.0 Mm And Drawer Sheet Thickness Of 0.7 Mm, With An Overall Size Of 765 Mm (L) × 465 Mm (W) × 812 Mm (H) And An Overall Height Of 976 Mm Including Casters. Drawers Of Size 536 Mm (L) × 410 Mm (W) × 74.5 Mm (H), Mounted On Precision Ball-Bearing Slides And The Top Panel Area Should Be Suitable For Tool Placement During Maintenance Work. The Unit Should Be Mounted On Four Heavy-Duty Casters Of Size 5? × 2?, Two Of Which Shall Be Swivel Casters With Locking Brakes For Easy Mobility And Stability During Use. The Cabinet Shall Include A Central Locking System For All Drawers, Should Be Surface-Treated With Powder Coating For Corrosion Resistance And A Smooth Finish. The Tool Cabinet Shall Conform, Where Applicable, To The General Guidelines Of Is 7155 (Industrial Trolleys And Cabinets) And Iso 9001:2015 Quality Manufacturing Standards. , Oil Drain Pan Made Of High-Density Polyethylene (Hdpe) With A Capacity Of 16 Litres Including Integrated Handles, A Pouring Spout, And Anti-Spill Lips To Prevent Leakage During Draining Suitable For Chemical Resistance To Engine Oil, Transmission Fluids, And Coolants. , Oil Drain Pan Made Of High-Density Polyethylene (Hdpe) With A Capacity Of 8 Litres Including Integrated Handles, A Pouring Spout, And Anti-Spill Lips To Prevent Leakage During Draining Suitable For Chemical Resistance To Engine Oil, Transmission Fluids, And Coolants. , Rack For Batteries, Made Of Well-Seasoned Hardwood Or Marine Plywood With Sturdy Ms Frame Or Wooden Supports. Includes 3-4 Ventilated Shelves With Acid-Resistant Coating And Removable Rubber Or Pvc Mat. Designed To Hold Multiple Batteries Safely And Prevent Corrosion. Approx. Size: 1500 Mm × 1000 Mm × 450 Mm. , Rack For Lubricants Constructed From Treated Wood Or Plywood Frame With Raised-Edge Shelves To Contain Spills. Each Shelf Shall Carry At Least 100 Kg And Be Coated With Oil-Resistant Paint. Suitable For 1-20 L Containers. Approx. Size: 1800 Mm × 1200 Mm × 450 Mm. , Rack For Spares Fabricated From High-Quality Wood Or Plywood With Ms Reinforcement. Includes Adjustable Or Fixed Shelves (3-5 Tiers), Each Supporting Up To 150 Kg (Udl). Finished With Protective Paint Or Polish For Workshop Use. Approx. Size: 2000 Mm × 900 Mm × 450 Mm. , Industrial Wet And Dry Type Vacuum Cleaner With A Power Rating Of 1500 W And Operating Voltage Of 220-240 V, 50 Hz, Suitable For Workshop And Service Bay Cleaning Applications With A Capacity Of 35 Litres, A Vacuum Suction Pressure Of 200 Mbar And An Airflow Rate Of 53 L/S, Ensuring High-Efficiency Dust And Liquid Removal. The Tank Should Be Made Of Corrosion-Resistant Stainless Steel (Minimum Ss 304 Grade) With Heavy-Duty Caster Wheels For Mobility. It Should Be Provided With A Flexible 5 M Power Cable, Washable Filters, Blower Function, And Accessories For Both Wet And Dry Operation. The Vacuum Cleaner Shall Conform To Iec 60335-2-69 (Safety For Wet And Dry Vacuum Cleaners For Commercial Use) Or Equivalent Indian Standard Is 11621:1986, And Include Overload And Thermal Protection Features For Motor Safety. , Portable, Electric-Operated Industrial Pressure Washer Conforming To Iec 60335-2-79 / Is 8442 With A Power Rating Of 1700 W (230 V, 50 Hz Single-Phase Supply) And A Maximum Working Pressure Of 130 Bar And A Flow Rate Of 7 Litres Per Minute, With Self-Priming Capability Of 0.5 M, High-Pressure Foam Detergent System, 6 M Pvc Hose, Manual Hose Reel, 5 M Power Cable, 3-In-1 Nozzle And Ergonomic Handle , Industrial Locker Cabinet (24-Door Type), Fabricated From 22-Gauge Mild Steel Sheet Pre-Treated And Powder-Coated For Corrosion Resistance And Smooth Finish With A Rigid Frame Structure, Each Locker Compartment With Individual Mechanical Key Locks Shall Measure Approximately 18 (D) × 12 (W) × 12 (H), With A Total Cabinet Size Of About 18 (D) × 48 (W) × 78 (H). A Load Capacity Of Minimum 10 Kg Including Ventilation Slots And Numbering Provision For Each Compartment , Safety , Abc Powder Type Fire Extinguishers, Is 15683:2018 Compliant, Portable Type With A Minimum Capacity Of 4 Kg Suitable For Class A Fires. Dry Chemical Powder (Mono Ammonium Phosphate) Based, Stored Pressure Type With Working Pressure Of 15 Bar, Suitable For Electrical And Combustible Material Fires.Extinguisher Should Have Isi Certification, Pressure Gauge, Discharge Nozzle, Wall Mounting Brackets, And Color Coding As Per Is 2190. They Shall Be Factory-Filled, Tested At Twice Working Pressure, And Supplied With Inspection Tag And Instruction Label. , Co2 Type Fire Extinguishers, Is 15683:2018 Compliant, Portable Type With A Minimum Capacity Of 4.5 Kg Suitable For Class B Fires . Carbon Dioxide Gas Type With Seamless High-Pressure Steel Cylinder Conforming To Is 7285, Discharge Hose With Horn, And Designed For Electrical And Flammable Liquid Fires. Extinguisher Sould Have Isi Certification, Pressure Gauge, Discharge Nozzle, Wall Mounting Brackets, And Color Coding As Per Is 2190. They Shall Be Factory-Filled, Tested At Twice Working Pressure, And Supplied With Inspection Tag And Instruction Label. , Foam Type Fire Extinguishers, Is 15683:2018 Compliant, Portable Type With A Minimum Capacity Of 9 L, Suitable For Class C Fires. Stored Pressure Or Cartridge Type Using Aqueous Film-Forming Foam Suitable For Flammable Liquid Fires. Extinguisher Should Have Isi Certification, Pressure Gauge, Discharge Nozzle, Wall Mounting Brackets, And Color Coding As Per Is 2190. They Shall Be Factory-Filled, Tested At Twice Working Pressure, And Supplied With Inspection Tag And Instruction Label. , Fire Blanket Shall Be Made Of 840 Gsm Glass Fiber Or Kevlar-Coated Woven Fabric, Resistant To Temperatures Up To 550°C, Conforming To Is 11871 / Bs En 1869, And Provided In A Quick-Release Wall-Mount Case. Standard Blanket Size: 2.00 M × 1.00 M For Personnel Protection And Small Fire Suppression. , First Aid Box Of Size 32.5(H) X 28.5(W) X 8(D) Cmshall Conform To Is 13154 (Part 1-3), Made Of Powder-Coated Metal, Gi Or Abs Plastic, Waterproof And Corrosion Resistant, To Keep All Essential Medical Supplies For Industrial Workshops (Bandages, Antiseptics, Gauze, Adhesive Strips, Scissors, Burn Cream, Splints, Sterile Pads, And Cpr Mask). , Eye Wash Station Wall Mount Type, Made Of Stainless Steel Push Plate 12.7 Mm (1/2 Inch Bsp) Inlet, 4810 Ss, Providing Continuous Flow At 1.5 L/Min Per Outlet, Operated By A Push Plate, Complying With Ansi Z358.1 / Is 10592. , Foldable Stretcher Shall Be Lightweight Aluminum Or High-Tensile Steel Frame With Washable Canvas Sheet, Capable Of Carrying 120 Kg Load, Fitted With Safety Straps And Rubber Handles, Conforming To Is 1904 / En 1865. , Ppe: Helmets Hdpe Or Abs Shell, Is 2925 Compliant, Chin Strap, Sweatband, Impact-Resistant Up To 50 Joules. , Ppe: Goggles Polycarbonate Lenses, Anti-Scratch And Uv-Resistant, Is 5983 / En 166 Compliant, Side Shields. , Ppe Industrial Gloves: For Mechanical Work-Leather Or Nitrile (Is 6994); For Chemical Work-Pvc/Neoprene (En 374); For Electrical Insulation-Rubber Class 0 (Is 4770). , Ppe: Safety Boots Confirming To Is 15298 / En 20345 Compliant, Steel/Composite Toe Cap (200 J Impact), Oil- And Slip-Resistant Sole, Steel Mid Sole Antistatic. , Ppe: Protective Overalls With 100% Cotton 210 Gsm Or Fire-Retardant Fabric, Full-Sleeve, High-Visibility Reflective Tapes Per Is 15748 / En 20471. , Electrical Insulated Gloves Conforming To Is 4770 / Iec 60903, Suitable For Class 0 (1000 V Ac / 1500 V Dc) Electrical Protection, Made Of High-Dielectric Natural Rubber, Seamless, And Rolled Cuff Type. Each Glove Shall Undergo Routine Dielectric Test At 5 Kv For 1 Minute With No Puncture Or Flashover. The Gloves Shall Be Category Rc (Resistant To Acid, Oil, Ozone, And Low Temperature) And Provided With A Cotton Inner Liner And Storage Pouch. Supplied With Test Certificate Indicating Batch Number, Test Voltage, And Date. , Welding Face Shield Suitable For Full-Face Protection During Welding, Grinding, And Metal Fabrication Works With A Shield Size Of Approximately 9 X 12, Made Of Durable Polypropylene Providing High Impact, Heat, And Corrosion Resistance. The Face Shield Shall Include An Adjustable Ratchet-Type Headgear With Multiple Adjustment Positions To Ensure A Secure And Comfortable Fit For Prolonged Use. The Approximate Weight Shall Be 1.5 Kg Or Less, And The Product Shall Be Supplied As One Complete Unit. The Face Shield Should Conform To General Industrial Safety Standards Suitable For Use In Workshops. , Industrial-Grade Welding Gloves Suitable For Providing Protection, Comfort, And Dexterity During Welding, Cutting, And Metal Fabrication Operations, Made From Premium Split Leather (Cowhide Or Goatskin) With A Minimum Thickness Of 1.2 Mm, Offering High Resistance To Heat, Sparks, And Mechanical Abrasion. The Inner Lining Shall Be Made Of Soft Flame-Retardant Cotton Or Fleece, Providing Insulation Against Heat And Comfort For Prolonged Use. Each Glove Shall Have Reinforced Palm And Finger Patches For Added Durability And Better Grip While Handling Tools And Hot Metal Objects. The Gloves Should Be Stitched With Heat-Resistant Thread To Prevent Seam Failure During Exposure To High Temperatures. The Length Shall Not Be Less Than 14 Inches (350 Mm), Ensuring Full Hand And Wrist Protection, With Extended Cuffs To Safeguard The Lower Forearm Against Welding Spatter And Radiant Heat. The Gloves Should Be Conformed To En 388 (Mechanical Risks) And En 407 (Thermal Hazards) Or Equivalent Indian Standards (Is 6153). They Shall Be Suitable For Mig, Tig, Arc, And Gas Welding Operations. Should Be Heat And Flame-Resistant, Puncture And Tear-Resistant, And Designed For Repeated Use In Demanding Industrial Environments. The Pair Shall Be Supplied In Standard Size (Large/Universal Fit) And Shall Bear Proper Labeling Indicating Brand, Size, And Conformity To Relevant Standards. , Lifting And Hoisting , Heavy-Duty, Low-Profile Type Hydraulic Trolley Jack Suitable For Lifting Vehicles Or Machinery Up To A Rated Capacity Of 3 Tons. The Jack Shall Be Constructed From High-Grade Steel With Welded Frame For Superior Strength And Stability, A Lifting Range From Approximately 130 Mm To 465 Mm, Operated Through A Hydraulic Lifting Mechanism Actuated By A Detachable Pump Handle. Should Be Equipped With A Safety Overload Valve To Prevent Lifting Beyond Rated Capacity, And Precision Hydraulic Seals To Prevent Oil Leakage. The Unit Shall Feature A 360° Swivel Rear Caster And Wide Front Wheels For Easy Maneuverability. The Saddle Shall Be Grooved Or Rubber-Coated For Secure Load Contact. The Jack Shall Conform To Is 7620 / Asme-Pase Or Equivalent Standards, And Shall Be Finished With Corrosion-Resistant Powder Coating. Supplied Complete With Hydraulic Oil Filled And Ready For Use. , Industrial-Grade, Floor-Operated Type Hydraulic Trolley Jack Suitable For Lifting Heavy Vehicles, Machinery, Or Agricultural Equipment Up To A Maximum Capacity Of 5 Tons. The Construction Shall Be Of Robust, All-Steel Design With Reinforced Chassis And Welded Seams For Durability. It Shall Have A Lifting Range From Approximately 150 Mm To 500 Mm, Operated By A Long Detachable Handle Providing Sufficient Leverage For Smooth Lifting. The Hydraulic System Shall Incorporate A Safety Overload Bypass System, Precision Machined Piston And Pump For Consistent Performance, And A Reliable Lowering Control Valve For Controlled Descent. The Jack Shall Be Equipped With Steel Swivel Casters, Wide Stance For Stability, And A Saddle Plate With Anti-Slip Surface. The Surface Finish Shall Be Rust-Resistant Enamel Or Powder Coating. The Unit Shall Comply With Relevant Is/Ansi/Ce Safety Standards, Factory-Tested For Rated Load, And Supplied Ready For Workshop Service. , The Hydraulic Bottle Jack Of 10-Ton Rated Capacity, Suitable For Lifting Tractors, Vehicles, Or Heavy Structures. The Jack Body Shall Be Made Of High-Tensile Steel With Precision Machining For Durability And Stability. It Shall Have A Lifting Range From Approximately 200 Mm To 400 Mm, Incorporating A Screw Extension On The Ram For Height Adjustment. The Hydraulic System Shall Be Fitted With A Built-In Safety Overload Valve And High-Quality Seals To Prevent Leakage. The Operating Handle Shall Be Detachable And Designed For Easy Pumping Action. The Base Shall Be Wide And Stable To Ensure Safety During Lifting Operations. The Jack Shall Conform To Is 10672 / Asme B30.1 Or Equivalent Standards, And Finished With Corrosion-Resistant Paint. Supplied Fully Assembled, Tested, And Filled With Hydraulic Oil. , The Jack Stands Shall Be Of Heavy-Duty Ratchet Or Pin-Lock Type, Designed To Support Loads Up To 3 Tons Per Pair. Each Stand Shall Be Fabricated From High-Grade Steel With A Broad, Stable Base And A Ratcheting Support Column Providing Positive Load Engagement. The Height Adjustment Range Shall Be Approximately 290 Mm To 430 Mm, With Fine-Tooth Ratchet Mechanism Or Pin-Lock System Ensuring Secure Positioning. Each Stand Shall Include A Safety Locking Mechanism To Prevent Accidental Lowering Under Load. The Saddle Shall Have A Contoured Top For Stable Seating Under Vehicle Lifting Points. All Structural Components Shall Be Fully Welded And Finished With Corrosion-Resistant Powder Coating. The Stands Shall Meet Asme-Pase / Ansi Pald Or Equivalent Safety Standards. Supplied As A Matched Pair, Factory-Tested For Load Stability And Mechanical Integrity. , The Hydraulic Engine Hoist Shall Be A Foldable, Mobile Workshop Crane With A 2 Ton Rated Lifting Capacity, Suitable For Lifting, Removing, And Installing Vehicle Engines Or Heavy Assemblies. The Frame Shall Be Made Of High-Strength Steel Sections With A Reinforced Boom, Hydraulic Lifting Ram, And Heavy-Duty Castor Wheels For Mobility. The Boom Shall Have Adjustable Reach Positions (E.G., 500 Kg, 1000 Kg, 1500 Kg, 2000 Kg) With A Lifting Range Of Approximately 0 - 2300 Mm. The Hydraulic Ram Shall Be Operated Via A Detachable Handle And Equipped With A Safety Overload Valve To Prevent Overloading. The Hoist Shall Feature A Folding Design For Space-Saving Storage, And A 360° Swivel Hook With Safety Latch For Secure Load Handling. The Finish Shall Be Industrial Enamel Or Powder-Coated For Corrosion Protection. The Equipment Shall Comply With Is 7631 / Asme B30.20 / Ce Standards And Supplied Ready For Operation. , The Tractor Splitting Stand Shall Be Designed For Safe Splitting And Assembly Of Tractors During Clutch Or Transmission Repairs. The Unit Shall Consist Of Two Independent Rolling Stands, One Front And One Rear, Each With Adjustable Height And Wheel-Mounted Base To Facilitate Easy Alignment And Movement Of Tractor Halves. The Front Cradle Shall Support The Clutch Housing Or Engine Section, While The Rear Stand Supports The Transmission Or Rear Axle Section. Both Stands Shall Be Constructed From Heavy-Duty Fabricated Steel Sections With Mechanical Screw Or Hydraulic Lifting Arrangements Providing A Height Range Of 400 Mm - 800 Mm. The Stands Shall Be Fitted With Locking Pins, Adjustable Supports, And Safety Chains To Prevent Accidental Movement. Load Capacity Shall Be Minimum 2 Tons Per Pair. The Entire Unit Shall Be Powder-Coated For Durability And Conform To Workshop Safety Standards For Agricultural Machinery Maintenance. , The Transmission Jack Shall Be A Hydraulic Telescopic Type Suitable For Removing And Installing Vehicle Transmissions Or Gearboxes From Underneath The Lift. The Rated Load Capacity Shall Be 0.5 Ton, With A Lifting Range Of Approximately 1100 Mm To 1900 Mm. The Lifting Mechanism Shall Be Actuated By A Foot-Operated Hydraulic Pump For Hands-Free Operation. The Tilting Head Plate Shall Provide Front, Rear, And Side Adjustment Through Fine-Thread Screws To Aid Alignment During Installation. The Base Shall Be Wide And Equipped With Four Swivel Castor Wheels For Stability And Maneuverability. The Unit Shall Have A Safety Overload Valve, Heavy-Duty Hydraulic Seals, And A Controlled Lowering Valve. It Shall Conform To Asme Pase / En 1494 Standards And Be Supplied Fully Assembled And Oil-Filled. , The Chain Block Shall Be A Manual, Hand-Operated Lifting Device Of 2 Ton Rated Capacity, Suitable For Workshop And Field Lifting Applications. It Shall Have A Mechanical Gear System Enclosed In A Steel Casing, Operating A Load Chain Made Of Grade 80 Alloy Steel With High Tensile Strength. The Standard Lift Height Shall Be 3 M - 6 M, With An Option For Extended Lift Lengths. The Mechanism Shall Incorporate A Load Brake With Dual Pawls For Positive Load Holding And Safety Hooks With Safety Latches At Both Ends. The Hand Chain Shall Run Smoothly On Precision-Machined Sprockets. The Unit Shall Conform To Is 3832 / Asme B30.16 / En 13157, With Load Testing Certificates And Corrosion-Resistant Paint Finish.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
13.
Educational and Research Institute #9617219 AOC
Tender For Supplying, Installation, Testing And Commissioning Of Machines & Equipment For Civil Engineering Department At Ttaadc Polytechnic Institute, Khumulwng, West Tripura For The Project Improvement Of Infrastructure In Ttaadc Polytechnic Institute, Khumulwng, West Tripura District Under Higher Education Department Under The Nec Scheme. , Supplying, Installation, Testing And Commissioning Of Machines & Equipment In Civil Engineering Department At Ttaadc Polytechnic Institute, Khumulwng, West Tripura Under The Nec Scheme Improvement Of Infrastructure In Ttaadc Polytechnic Institute, Khumulwng, West Tripura, District Under Higher Education Departmen. , Computerized Universal Testing Machine, 6 Pillar Type, For Conducting Tests On Various Types Of Ferrous And Non-Ferrous Materials; Consisting Of- Loading Unit 600 Kn Capacity, Hydraulic Jaws And Pumping System, Clamping Jaws For Round Specimens, Clamping Jaws For Flat Specimens, Pair Of Compression Plates, For Compression Test, Rollers Of 160 Mm Width And 30 Mm Diameters, For Transverse Test, Bending Table Stopper, Allen Keys, Spanners, Double Shear Test Attachment, Bend Rebend Test Attachment, Electronic Extensometer. , Steel Bar Cutting Machine , Vernier Caliper , Stainless Steel Ruler, 1M Length , Mixer Machineries Concrete Mixer The Counter Balanced Mixing Drum Is Easy To Tilt Two Cubic Feet Mix Capacity. Total Drum Volume Is 3 Cubic Feet.. Suitable For Operation On 220 Volt Single Phase, 50 Cycle, A.C. Supply , Isi Cube Mould Cube Mould, With Base Plate : As Per Is : 516 With Isi Mark Cube Mould, 15 Cm X 15 Cm With Base Plate (Made Of Cast Iron - Isi Mark) , Cement Mortar Cube Mould Cement Mortar Cube Mould Cube Mould, 7.06Cm X 7.06Cm With Base Plate (Made Of Mild Steel) , Vibrating Machine Vibration Machine With Timer : Is : 4031 This Apparatus Is Suitable For Making Cubes Of 70.7 Mm. For Mortar Strength Evaluation. The Mould Is Mounted On A Vibrating Platform With A Frequency Of 12,000±400 Vibrations Per Minute. To The Platform Are Attached Four Matched Springs. The Whole Assembly Is Operated By A Revolving Shaft With An Eccentric Mechanism. The Machine Is Supplied With A Timer, A Switch Mounted On A Steel Panel And A 70.7 Mm. Steel Cube Mould With A Base Plate. , Electronic Balance Capacity 500Gm, 0.01 Gm Accuracy , Electronic Balance Capacity 5Kg, 0.1 Gm Accuracy , Electronic Balance Capacity 20Kg, 0.5 Gm Accuracy , Electronic Balance Capacity 100 Kg, 10G Accuracy , Air Permeability Apparatus (Blaine Type) Isi Certification Mark Is;5516, Fitted In Aluminium Box , Vibrating Table Vibrating Table For Compaction Concrete Cube, Cylinders The Table Deck Size 50 Cm X 50 Cm And Has Stops Along Its Edges To Prevent Moulds From Walking Off The Table During Vibration The Variably Pitch Pulley Arrangement Permits The Frequency To Be Varied Sleeplessly Between A Maximum Of 3600 Vibrations Per Minute A Speed Regulation Handle Is Provided For Increasing Or Decreasing The Frequency. The Vibrating Deck. A Switch Is Provided For Starting The Motor. Operation On 440 Volts, Three Phases, A.C. Supply. Table Top - 50 Cm X 50 Cm , Curing Tank Water Curing Bath With Agitation System Digital Indicator For Temperature * 24- Hour Cycle From Time Of Mixing * Controlled 100° C +/- 2° C. Temp. For Concrete * Controlled 27° C + 2° C Curing Temperature For Grey Cement The Tank Has Been Designed To Accommodate 150 Mm / 70.6 Mm Casted Cubes Up To 12/24 Cubes And Fully Insulated. Complete With A Hinged Lid, Heated, Thermostat And Recirculation Pump. Provision Of Two Removable Racks Allowing Free Circulation Of Water Around Each Cube. The Pump, Drain Valves And Electrical Equipment Are Housed In A Compartment Located At One End Of The Tanks. The Tank Is Heated By An Immersion Heater Under Normal Conditions And Refrigeration System For Grey Cement, The Temperature Is Controlled At 35Deg.C. +/- 2 Deg.C, For About 15 Minutes After Immersion Of The Freshly-Made Specimens. Curing Tank For 12 Moulds Of 150Mm/24 Moulds Of 7.06Mm , Vicat Apparatus Box With Isi Certification Mark, Is:5513, Fitted In Aluminium , Le-Chatelier Mould With Isi Certification Markis:5514, Each , Le-Chatelier Water Bath Controller Size 12X9x12. , Crushing Test Apparatus Based On Is: 9376-1979, Mould And Accessories Which Consists Of A Steel Cylinder Of 150Mm Dia. A Plunger And A Steel Base Plate. , Slump Cone With Tamping Rod Slump Test Apparatus Is : 1199 Is ; 7320 Consists Of Slump Cone Fitted With Handles And Foot Pieces In Position. Base Plate In Octagonal Shape Two Clamps Slide Over The Foot Grips Of A Standard Slump Cone And Hold It Securely While Filling And Roding. A Combination Swivel Carrying Handle. Complete With Graduated Temping Rod 0-60 Cms Long And 16Mm Dia With 0-30 Cms Scale Graduation , Measuring Cylinder(Plastic)(1 Liter) , Measuring Cylinder(Plastic) (500 Ml) , Measuring Cylinder(Plastic) (100 Ml) , Measuring Cylinder (Glass) (1 Liter) , Measuring Cylinder (Glass) (250 Ml) , Le-Chatelier Flask Or Specific Gravity Bottol (Glass) 250 Ml , Glass Funnel , Compaction Factor Apparatus Compaction Factor Apparatus: Is : 5515: Is:1199 Consists Of Two Conical Hoppers And A Cylinder Mounted On A Rigid Metal Frame The Lower Openings Of The Hoppers Are Fitted With Hinged Trap-Doors For Release And During The Fall Of Material. Complete With Trowel Tamping Bar 0-60Cms Long X 16Mm Dia , Sample Tray (Enamel Tray), Size 650X500x50mm , Sample Tray (Enamel Tray), Size 850X600x50mm , Pycnometer/Specific Gravity Bottle (1 Litre) , Cylindrical Mould 150 Mm Dia X 300 Mm High, Cast Iron. , Beam Mould 150 Mm X 150 Mm X 700 Mm Made Of Cast Iron , Beam Mould 100 Mm X 100 Mm X 500 Mm Made Of Cast Iron. , Sample Tray (Enamel Tray), Size 350X300x80mm , Sample Tray (Enamel Tray), Size 250X200x50mm , Sample Tray (Enamel Tray), Size 450X400x50mm , Trowel, Ref Standard Is: 4031, 100 To 150Mm Long Blade With Straight Edge. Weight 210 + 10G , Trowel, Ref Standard Is:5515, 200Mm Long Blade, Weight 210 + 10 G , Spatula, 200Mm Blade With Wooden Handle , Density Basket , Hand Brush , Plastic Water Measuring Cylinder (1 Liter) , Plastic Jar For Measuring Water (500 Ml) , Plastic Jar For Measuring Water (100 Ml) , Asbestos Gloves , Hammer With Wooden Handle , Vernier Caliper , Circular Pan/Tray For Morter Mixing , Digital Compression Testing Machine, As Per Is : 14858-2000, 2000Kn Capacity, Electrically Operated With Three Load Gauges 2000Kn, 1000Kn, 500Kn With Nabl Calibration Certificate With Traceability Certificate. , Standard Penetration Test (Spt) Set Consisting Of Split Spoon Sampler, Drive Weight, Guide Pipe Assembly, Tripod, With Rope 19Mm Dia X 10 Mt Length A Drill Rod, 1M Long Complete With Adaptor, 10 Nos Hand Operated Extractor 38Mm Mm Dia. Specimen , Portable Digital Dissolved Oxygen Meter Display : Lcd Size : 29 Mm X 28 Mm Dual Function Lcd Accuracy : Dissolved Oxygen:+0.1Mg/L, Oxygen In Air:+ 0.1% O ², Temperature:+ 0.8 °C/1.5 °F Resolution : Dissolved Oxygen:0.1Mg/L, Oxygen In Air:0.1% O ² Temperature:0.1 °C. Data Hold: Freeze The Display Reading. Operating Conditions: Temp: 0 To 50 Deg C, Humi: Less Than 80% Rh. Operating Range: Temperature: 0 °C To 50 °C (32 °F To 122 °F) Humidity: Max. 80% Rh. Power Off : Auto Shut Off Saves Battery Life, Or Manual Off By Push Button Power Supply : Dc 1.5V Battery ( Um-4/Aaa ) X 4 Pcs Protection Class: Ip-65: 0 To 50, Ip-67: 0 To 30. Dimensions: 180 X 40 X 40 Mm (7.1 X 1.6 X 1.6 Inch). Weight : 176 G/0.39 Lb Memory Recall: Records Maximum, Minimum And Average Readings With Recall. Measurement & Range : Dissolved Oxygen:0 To 20.0 Mg/L, Oxygen In Air:0 To 100.0 %, Temperature:0.1 , Digital Chlorine Meter •The Meter Measures The Free And Total Chlorine (Cl) In The 0.00 To 3.50 Ppm (Mg/L). The Measuring Method Is An Adaption Of The Usepa Method 330.5 For Waste Water And Standard Method 4500-Ci G For Drinking Water. Range: Free Chlorine (Cl): 0.00 To 3.50 Ppm (Mg/L), Total Chlorine (Cl): 0.00 To 3.50 Ppm (Mg/L). Resolution: 0.001(Mg/L). Light Source: Led, 525 Nm. , Digital Tds Meter Using Latest Microcontroller, Auto Ranging (5 Ranges From 200Ppm To 1000Ppt), Temperature Compensation, Auto Cell Constant Measurement, Touch Keys Along With Tds Cell. (Table Model) , Vertical Double Water Distillation Apparatus Temperature 400 Degree Celcius, Color : Transparent, Frequency: 50 Hz, Display: Manual, Weight 10 Kg, Voltage 220Volt, Capacity 5000 Ml With Two Glass Flask With Embedded Heater In Spiral Type Glass Coil Internally At The Bottom, Double Wall Condenser, Level Cup, Delivery Tube, Metal Stand , Clamp, Boss Head, With Automatic Cutoff Device Etc. As Required , Biological Oxygen Demand (Bod Incubator) Temperature Range From 5 °C To 50 °C. Inner Chamber Made Of Stainless Steel, Temperature Controlled And Indicated By Automatic Solid State Electronic Digital Temperature, Controller Cum Indicator. Outer Body Made Of Thick Gauge M.S. Sheet And Inner Chamber Made Of Stainless Steel. Both The Wall Gapis Highly Insulated With Glass Wool. Door Is Also Double Walled And Insulated With Glass Wool Hanged With Heavy Hinges And Fitted With Rubber Magnetic Gasket. An Inner Glass Door Is Provided For Viewing The Samples On While On Test. A Finned Type Low Wattage Heater Is Provided For Raising Temperature Up To 50°C. A Sealed Type Thermostatically Sealed Compressor Filled With Free On Gas And Fitted With All Accessories Viz. Condenser Capacitor Etc. Are Provided At The Bottom Of The Chamber. Copper Cooling Coils Are Provided With The Chamber For Easy And Uniform Refrigeration Throughout The Working Chamber And Capable To Come Down The Temperature At 5 Deg.C From The Ambient Temperature. A Turbo Type Blower A Fitted With Suitable Electric Motor Are Provided Inside The Working Chamber To Circulate The Hot And Cold Air For Uniform Temperature At Any Desired Temperature. Temperature Is Controlled By A Pid Controller Relay With An Accuracy Of +/- 1C Or 0.5C Supplied Complete With Neon Indicating Lamps, Main Cord, Switch, Hot And Cold Switches, Supplied With Perforated Aluminium Shelves Operated On 220/230 Volt, Single Phase, And 50 Hz. Ac Mains. Capacity: 6 Cubic Ft. , Chemical Oxygen Demand (Cod Incubator It Is Solid Block Heated Unit With Provision For Samples To Be Digested At A Time In 38Mm Dia. Reaction Vessels With 20Ml Sample Size Of Heat At Temp. 150 °C Controlled By Digital Temp. Indicator Cum Controller. It Has Provision For 6 Samples And Is Supplied With 6 Nos. Glass Reaction Vessels And 6 Nos. Air Condensers. Fitted With A 2 Hour German Timer (Including 6 Samples Test) - To Be Supplied With All Accessories. , Jar Test Apparatus Using Latest Microcontroller, Highly Accurate Digital Rpm Indicator Which Can Be Varied From 25 To 200 Rpm, Digital Timer From 1 To 99 Minutes With Alert Sound. Two Pre-Set Programs Allow Routine Speed And Time Parameters To Be Input And Then Selected By Simply Pressing One Button. Parameters Stored In The Battery Backup Memory. , Ph Meter Type: Digital, Ph Range: 0 To 14, Resolution: 0.01Ph, Compensation: 0 To 80 Degree C , Bod Bottel, Capacity 300 Ml , Modified Proctor Apparatus As Per Is:10074:1982 & 2720 (Part Viii), Specification, Made Of Mild Steel Dia: 150Mm, Height 127.3 Mm, Volume: 2250 Cc, Complete With Base Plate And Collar , Rammers, Weight 4.89 Kg Controlled Drop 410 Mm , Maxwell Reciprocal Theorem Apparatus Maxwell Reciprocal Theorem Apparatus Apparatus Consist Of A Mild Steel Beam 100Cm Long And 1.25Cm X 4Mm In Cross Section With Graduations At Every 10Cm Along The Length. It Should Be Supported On Two Knife Edge Supports 70Cm Apart With A 30Cm Overhang On One Side. Reciprocal Theorem Can Be Verified By Direct Measurements Of The Deflections Of Various Points With The Help Of A Dial Gauge Due To A Load Placed At The Reciprocal Points. A Dial Gauge With 25Mm Travel (With A Magnetic Base) Should Be Supplied With The Apparatus. Apparatus To Be Supplied Should Be Complete With A Supporting Stand And A Set Of Weights. , Two Hinged Arch Apparatus Apparatus Has A Span Of 100Cm And Rise 25Cm. Both Ends Should Have Hinge But One Of The Ends Should Also Be Free To Move Longitudinally. A Lever Arrangement Fitted At This End For The Application Of Known Horizontal Inward Force For Measuring The Horizontal Thrust. Along The Horizontal Span Of The Arch Various Points Are Marked At Equidistant For The Application Of Load. This Being A Statically Indeterminate Structure Of The First Degree. A Dial Gauge With 25Mm Travel (With Magnetic Base) Is To Be Supplied With The Apparatus. Mild Steel Apparatus Complete With A Supporting Stand And A Set Of Weights. , Pin Jointed Truss Apparatus Experimental And Analytical Study Of 1 3 Bar Pin Jointed Truss Apparatus Consists Of Three Suspension Members (Spring Balances) Of Different Stiffness Which Are Jointed At A Point To Form The Redundant Joint. The Upper End Of The Suspension Members Being Tied In A Position To A Vertical Wooden Board. Arrangement Is Provided On A Paper And Also Elongations And Forces In The Suspension Members. , Unsymmetrical Bending Apparatus Apparatus Consist Of An Angle Of Size 1 X 1 X 1/8 Or In Equivalent Metric Units Of Length 80Cm Is Tied As A Cantilever Beam. The Beam Is Fixed At One End Such That The Rotation Of 450 Intervals Can Be Given And Clamped Such That The Principal Axis Of Its Cross-Section May Be Inclined At Any Angle With The Horizontal And Vertical Planes. Also Arrangement Is Provided To Apply Vertical Load At The Free End Of The Cantilever And To Measure Horizontal And Vertical Deflection Of The Free End. A Dial Gauge With Magnetic Base Is Supplied With The Apparatus. , Curved Member Apparatus Apparatus Consists Of A Steel Bar Which Is Used To Make The Different Curved Member Viz. Circle, Semicircle With Straight Arm, A Quadrant Of A Circle And Quadrant Of A Circle With Straight Arm. The Bottom Ends Of The Members Are Fixed To The Base. Under The Application Of Load At Free End, Its Horizontal And Vertical Deflection Can Be Measured With The Help Of Dial Gauges. A Dial Gauge With 25Mm Travel (With A Magnetic Base) Is Supplied With The Apparatus. Apparatus Will Be Supplied Complete With A Supporting Stand And A Set Of Weights , Schimidt Rebound Hammer Test Specification Impact Energy Type N 2.207 Nm (1.63 Ft Lbf) Concrete Compressive 10 To 100 Mpa (1450 To 14500 Psi) Strength Range Types N/L Dimensions Of Housing 55 X 55 X 255Mm (2.16X2.16 X9.84) Weight 570 G Max. Impacts Per Series Memory Capacity Ca. 400 Series Of 10 Impacts (Pc Version Only) Useful Memory Capacity St Version Ca. 200 Series Of 20 Impacts Last 20 Series May Be Reviewed In The Data List Display 17X 71 Pixel, Graphic Battery Life 5000 Impacts Between Charges Charger Connection Usb Type B/C (5V, 100 Ma) Operating Temperature 0 To 50°C (32 To 122°F) Storage Temperature -10 To 70°C (14 To 158°F) Ip Classification Ip54 , Venturi Meter (Bernoullis Theorem Demonstration) Venturi Section Machined From Clear Acrylic, Seven Static Pressure Tappings Plus A Total Head Measurement, Flow Control Valve, Manometer Board With Eight Tubes, Quick-Release Fitting For Easy Connection To Hydraulics Bench. Manometer Range: 0-300 Mm, Number Of Manometer Tubes: 8, Throat Diameter: 10.0 Mm, Upstream Diameter: 25.0 Mm, Upstream Taper: 14°, Downstream Taper: 21, Height: 0.60 M, Width: 0.55 M, Depth: 0.25 M. , Orifice Meter Orifice Discharge Accessory Enables Full Analysis Of The Flow Through Seven Different Orifices Over A Range Of Flow Rates. Determining The Construction And Velocity Coefficients, Calculating The Discharge Coefficient Standard Orifice: Sharp-Edged 13Mm Diameter, Max Head: 365Mm, Traverse Mechanism: Lead Screw With Adjusting Nut Calibrated 0.1Mm Per Division, Height: 0.60 M, Width: 0.33 M, Depth: 0.33 M. , Water Hammer Apparatus A Self-Contained Unit Designed To Demonstrate The Phenomena Of Pipe Surge And Water Hammer. Straight Pipes Are Used, Rather Than A Coiled Arrangement, To Reduce Distortion Of The Pressure Wave. Test Pipes: Stainless Steel, 20.2Mm Inside Diameter, Nominally 3M Long, Surge Shaft: Clear Acrylic, 40Mm Inside Diameter, 800Mm High, Head Tank: Pvc, Capacity 45 Litters, Gross Weight: 420 Kg, Volume: 5 M3, Height:1.865 M, Length: 3.575 M, Depth :0.725 M. , Tilting Flume Apparatus (Adjustable Channel) Tilting Flume Apparatus (Adjustable Channel) Specifications The Tilting Flume Apparatus Should Be Approximately 4 Meter Long Open Channel With 200 Mm Width And 300 Mm Depth. Manual Adjustment Of Slope. Pump Capacity: 1 Hp. Designed To Conduct Various Experiments At Various Bed Slopes With Mechanism To Read The Bed Slope. Screw Jack Arrangement Is Provided To Adjust The Bed Slope Of The Channel As Desired. The Flume Has A Perspex Window At Specific Spots Where Structure Such As Weir, Spillway, Or V Notch Will Be Installed To Visualize The Flow Over Models Fixed In Flume. Trolley Mounted Point Gauge For Level Measurement Of Water. Trolley Can Be Traversed For Whole Length Of Flume. The Mechanism Should Be Able To Read Y And Z Coordinates Along With The X-Coordinate. The Flume Is Provided With Gates On Upstream & Downstream Side To Control The Flow. Various Experiments Like Flow In Open Channel, Hydraulic Jump, And Calibration Of Weirs, Notches And Venturi Flume Can Be Conducted. An Orifice Meter With Manometer Is Provided To Determine The Discharge Provided To The Open Channel By The Feeder Pipe. This Is Used For The Calibration Of The Weirs And Notches. The Set Up Should Be Provided With A Pump Of Adequate Capacity For Recalculating The Water Supply. It Should Be Provided With Collecting And Supply Tank. Stop Watch Be Provided For Recording Time And With Lab Manual. Scope Of Experimentations: • To Calibrate The Notches & Weirs. • To Study About Hydraulic Jump. • To Study Flow Through Venturi Flume. To Study Specific Energy Curves , Metacentric Height Apparatus Determining The Centre Of Gravity Of The Pontoon, Determining The Metacentric Height And From This The Position Of The Metacentre For The Pontoon, Varying The Metacentric Height With Angle Of Heel, Max Angle Of Heel: ±13°, Corresponding Linear Dimension: ±90Mm, Height: 0.475 M, Width: 0.35 M, Depth: 0.20 M. , Pitot Tube Apparatus Description: The Designed Pitot Tube Unit The Change In Flow Speed Within A Tube Can Be Determined. The Pitot Static Tube Can Be Moved Across The Whole Cross- Section Of The Tube, And Thus To Measure The Pressure Profile. This Tube Is Connected To Manometers Via Hoses. The Pitot Tube Can Be Moved Across The Cross-Section Of The Pipe In Order To Measure The Dynamic Head Profile. The Position Of The Measuring Tip Relative To The Wall Of The Pipe Can Be Read On A Scale. The Pitot Tube Is Connected To A Pressurized Water Manometer To Measure The Differential Head Across The Pitot Static Tube. The Position Of The Measuring Head Relative To The Bottom Edge Of The Tube Can Be Measured On A Scale. The Water Supply Can Come From The Hydraulics Bench Or From The Basic Hydraulic Feed System. The Pitot Tube Can Be Moved Across The Cross-Section Of The Pipe In Order To Measure The Dynamic Head Profile. Features: •Study Of The Function Of A Pitot Static Tube. •To Use A Pitot Static Tube. •Determination Of Tube Flow Speed Profiles. •Demonstration That The Flow Speed Is Proportional To The Pressure Difference Between The Total Pressure And The Static Pressure. •Error Determination In Flow Measurements Using The Pitot Tube As Measurement Instrument. • Factor Cd Determination In The Pitot Tube. • Operation Of A Pitot Static Tube And Pressurized Water Manometer • Velocity Flow Profile In A Pipe • Demonstration That The Fluid Velocity Is Proportional To The Square Root Of The Head Difference Between The Total Head And The Static Head Specification: • Pitot Static Tube: Head Diameter: 2.5 Mm. • Transparent Pipe: 32 Mm. Internal Diameter • Transparent Pipe: 430-Mm.-Length Approx. • Hose Connections. • Water Manometer, 500 Mm. Length. • Easy And Quick Coupling System • Built-In. Anodized Aluminum Structure And Panel Of Painted Steel. • Dimensions And Weight • L X W X H: 800-X600 X 600 Mm • Weight: 40Kg
Contract Date: Feb 19, 2026 Contract Value : 34.03 Lakh
Local Bodies No of Bidders 4
14.
Defence #9578160 AOC
Tender For Provision Of Otm Accommodation (Phase -I) At Bagrakote Under Ge Sevoke; 1 BUILDINGS & STRUCTURE (Sch A PART-I) 2 Lump sum price worked out by the Contractor for “BUILDINGS & STRUCTURE”as listed in Schedule ‘A’ Part-I.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs. 36,31,20,000.00 inserted by the MES in Schedule ‘A’ Part-I. 3 EARTHWORK, SITE CLEARANCE AND SITE DEVELOPMENT (Sch A PART-II) 4 Lump sum price worked out by the Contractor for “EARTHWORK, SITE CLEARANCE AND SITE DEVELOPMENT”as listed in Schedule ‘A’ Part-II.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs. 52,49,260.89 inserted by the MES in Schedule ‘A’ Part-II. 5 INTERNAL WATER SUPPLY (Sch A PART-III) 6 Lump sum price worked out by the Contractor for “INTERNAL WATER SUPPLY”as listed in Schedule ‘A’ Part-III.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs. 46,308.98inserted by the MES in Schedule ‘A’ Part-III. 7 INTERNAL ELECTRIFICATION (Sch A PART-IV) 8 Lump sum price worked out by the Contractor for “(INTERNAL ELECTRIFICATION)”as listed in Schedule ‘A’ Part-IV.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs. 96,32,540.67 inserted by the MES in Schedule ‘A’ Part-IV. 9 ROAD, PATH & CULVERT (Sch A PART-V) 10 Lump sum price worked out by the Contractor for “ROAD, PATH & CULVERT)”as listed in Schedule ‘A’ Part-V.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs. 86,86,643.57 inserted by the MES in Schedule ‘A’ Part-V. 11 SEWAGE DISPOSAL (Sch A PART-VI) 12 Lump sum price worked out by the Contractor for “SEWAGE DISPOSAL”as listed in Schedule ‘A’ Part-VI.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs. 23,70,861.02inserted by the MES in Schedule ‘A’ Part-VI. 13 AREA DRAINAGE(Sch A Part-VII) 14 Lump sum price worked out by the Contractor for “(AREA DRAINAGE)”as listed in Schedule ‘A’ Part-VII.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs. 64,06,702.01 inserted by the MES in Schedule ‘A’ Part-VII. 15 CHAIN LINK FENCING AND GATE (Sch A PART-VIII) 16 Lump sum price worked out by the Contractor for “(CHAIN LINK FENCING AND GATE )”as listed in Schedule ‘A’ Part-VIII.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs. 16,99,635.84 inserted by the MES in Schedule ‘A’ Part-VIII. 17 EXTERNAL WATER SUPPLY (Sch A PART-IX) 18 Lump sum price worked out by the Contractor for “EXTERNAL WATER SUPPLY”as listed in Schedule ‘A’ Part-IX.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs. 4,04,432.28inserted by the MES in Schedule ‘A’ Part-IX. 19 EXTERNAL ELECTRIFICATION (Sch A PART-X) 20 Lump sum price worked out by the Contractor for “(EXTERNAL ELECTRIFICATION)”as listed in Schedule ‘A’ Part-X.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs. 66,58,717.06 inserted by the MES in Schedule ‘A’ Part-X. 21 FIRE FIGHTING & FIRE ALARM SYSTEM (Sch A PART-XI) 22 Lump sum price worked out by the Contractor for “FIRE FIGHTING & FIRE ALARM SYSTEM”as listed in Schedule ‘A’ Part-XI.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs. 32,30,010.00inserted by the MES in Schedule ‘A’ Part-XI. 23 HOT WATER SUPPLY (Sch A PART-XII) 24 Lump sum price worked out by the Contractor for “HOT WATER SUPPLY”as listed in Schedule ‘A’ Part-XII.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs. 6,63,253.28 inserted by the MES in Schedule ‘A’ Part-XII. 25 LIGHTNING PROTECTION (Sch A PART-XIII) 26 Lump sum price worked out by the Contractor for “LIGHTNING PROTECTION”as listed in Schedule ‘A’ Part-XIII.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs. 29,821.10 inserted by the MES in Schedule ‘A’ Part-XIII. 27 COOLING APPLIANCES (Sch A PART-XIV) 28 Lump sum price worked out by the Contractor for “COOLING APPLIANCES”as listed in Schedule ‘A’ Part-XIV.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs. 4,24,714.16 inserted by the MES in Schedule ‘A’ Part-XIV. 29 DEMOLITION & DISMANTLING (Sch A PART-XV) 30 Lump sum price worked out by the Contractor for “DEMOLITION & DISMANTLING”as listed in Schedule ‘A’ Part-XV.Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 12,25,480.08 inserted by the MES in Schedule ‘A’ Part-XV. 31 MISCELLANEOUS ITEMS REQUIRED FOR B/R & E/M SERVICES (Sch A Part-XVI) 32 INTERNAL WATER SUPPLYS&F ofGun-metal, globe or gate valve, 65 mm bore of pipe, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed. 33 S&F ofGun-metal, globe or gate valves, 80 mm bore of pipe, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed. 34 S&F 15 mmbore brass CP mixer for hot & cold water screwed down for iron / CPVC pipe and fixed (3-in-1) complete all as specified and directed. 35 S&F 15 mm bore fancy type, chromium plated basin inlet connection (angle valve), cast copper alloy, screwed down, high pressure, screwed both ends for iron / CPVC pipe for unions and fixed complete all as specified and directed. 36 S&F two way bib cock with wall flange chromium plated with crutch or butterfly handle screwed down screwed for iron / CPVC pipe 15 mm borecomplete all as specified and directed. 37 S&F health faucet with stainless steeltube and wall hook suitable for 15 mm dia pipe with 1 meter long flexible tube including making connections and fixed in pipe etccomplete all as specified and directed. 38 INTERNAL ELECTRIFICATIONS & F modular type 3 pin 20 A socket with SP MCB, conforming to IS 1293: 2005 complete all as specified in IS 732: 2019 and directed.(AC& GYSER POINT) 39 S & F MCB 25A, 230 V, 50 Hz, 2P MCB (C curve) conforming to IS/IEC 60898-1-2002, having breaking capacity Icn = 10 kA, sliding bottom clamp, colour coded on/off indication on dolly, bi-connect IP 20 protected lower terminals and sliding shutters, etc. complete all as specified in IS 732: 2019 and directed. 40 All as per Srl Item No. 16.08 here-in-above but for 16A, 230 V, 50 Hz, 2P MCB (C curve) complete all as specified and directed. 41 S&F load line distribution board TPN vertical, 6 way double door type, fixed on wall semi flush with incoming MCCB 4 poles and, busbars , neutral link, blanking plates complete with all accessories all as specified and as directed. NOTE : Outgoing MCBs shall be measured and paid separately. 42 S & F of 125A, 4 pole moulded case circuit breaker (MCCB) with thermal magnetic trip unit (TMD), compression lug connectors, protection against overloads (Ir adjustable from 0.7- 1 X In), protection against short circuits (Isd adjustable from 5- 10 X Ir), inbuilt encapsulated double break roto active type instanteneous protection, earth fault leakage protection, etc. having Ics = 100% = Icu = 16 kA as per IEC 60947-2 and suitable for 3-Phase, 415 V, 50 Hz electric supply complete all as specified and directed. 43 S & F 40 W surface / wall mountedLED batten capable of delivering minimum 2000 lumen, having PC diffuser, luminous efficacy of > 90 lumen/W, CRI > 80, PF > 0.9, CCT 6500K,independent isolated SMPS based constant current electronic LED driver with THD < 20%, surge voltage protection and other safety tests as per IS 15885 (Part-2/Sec-13): 2012, polycarbonate diffuser, housed in powder coated white extruded aluminium channel housing. white coloured ABS end caps, IP 20 protection, input voltage range 140- 270 V, input frequency 50- 60 Hz, including electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose to the fixture complete all as specified and directed. 44 S & F 9W LED Study light having Luminous efficacy of > 100, input voltage range 140-270 V, input frequency 50-60 Hz complete all as specified and directed. 45 S & F surface mound Flame proof LED Batten, 20W, CRI > 70, suitable for Hazardous area group IIA and IIB and zone 1 & 2, IP 65 Protection with 100 lumens/watt with Die Cast Aluminium Housing, THD < 15% complete all as specified and directed. 46 SEWAGE DISPOSALConstruction of Septic tank (for 10 Users) conventional type, designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, Brick wall RCC M-25 in Roof Slabetc with Vent shaft , manhole openings with cover connection etc., complete with effective depth of 1.30 meter complete all as shown on TD drawings No CESZ/2019/TD-115 Sheets 1/4 to 4/4 and directed.NOTE : Necessary Earthwork shall be included in the quoted rate. 47 Construction of Soakage wells excavation, in any type of soil, walls of honey combed masonry, RCC cover slab in M25, bat filling interconnecting pipes of DWC complete filled with brick bats of size 1.20 M dia X 3.00 M effective depth complete all as shown on TD drawings No SZ/TD-14 Sheets 1/1 and directed.NOTE : Necessary Earthwork shall be included in the quoted rate. 48 M&L for 200 mm (inner dia) DWCPE (SN-8) pipe as per IS:16098 (Part-I) with all fittings and laid in trenches and jointed complete all as specified and directed. 49 EXTERNAL WATER SUPPLYSupply, laying and testing of 150 mm bore ductile iron pressure pipe socket and spigot end, class K-7, confirming to IS-8329/2000 blast furnace slag cement with portland cement properties suitable for push - on- joint with inside cement mortar lining, internal metallic zinc coationg and external black bitumen coating laid in trenches etc complete all as specified and directed. 50 Supply, laying and testing of 100 mm bore ductile iron pressure pipe socket and spigot end, class K-9, confirming to IS-8329/2000 blast furnace slag cement with portland cement properties suitable for push - on- joint with inside cement mortar lining, internal metallic zinc coationg and external black bitumen coating laid in trenches etc complete all as specified and directed. 51 M&L for construction of brick masonary valves pit of internal dimensions 900mm x 900 mm x 900 mm complete and fabrication of 3.0 mm thick MS Sheet cover and angle iron frame made out of 40mm x 40mm x 6 mm MS angle iron and one side provided with hinge with locking arrangement & duly painted with two coats of black bituminous paint over a coat of red oxide primer including necessary earth work and PCC work complete all as shown TD Drawing all as specified and directed. 52 S& F Cast Iron Air Valves with single air Outlets, conforming to IS 14845 of size 50 mm dia bore and fixing up in Water supply mains of size 150 mm dia complete all as specified and directed. 53 Supply and fix valve, reflux with by pass arrangement 150 mm (6) dia complete all as specified and as directed. 54 M & L for Trial bore of 200 mm dia below ground level in any kind of soil strata including hard stone/ boulder by deploying direct/reverse or universal method to achieve desired depth including cost of consumable stores like fuel,lubricants, bentonite mud, material and transportation of machinery etc., complete all as specified and as directed..NOTE : -(a) Erection and dismantling of boring plant including all arrangement for the transportation of boring equipment to site of work from the store of contractor at site and back are to be made by contractor at his own cost. All rates should be quoted for supplying the material at site of work.Pits for collection of water and water for drilling tubewell will be arranged by the firm/contractor at site his own cost.(b) Borewell to be done subject to permission by CGWB. 55 M & L for electro logging for identification of aquafier zone with report enterpretation, including fabrication of strata chart in wooden glass frame and strata box of size 1000x600x100mm made by woodshisham and 3mm glass in front of box for display in pump house complete all as specified and directed. 56 Reaming up to 350 mm dia for depth upto 60 mtr from ground level complete all as specified and directed. 57 Reaming up to 300 mm dia for depth from 60mtr from ground level to 110 mtr complete all as specified and directed. 58 S & F of including lowering in borewell ERW/ MS casing pipe electric resistant welded pipe with socket confirming to IS:3589 of 250mm dia and thickness 8mm including two coats of anti corrosive bituminous paint of approved brand complete all as specified and directed. 59 S & F of including lowering in borewell ERW/ MS casing pipe electric resistant welded pipe with socket confirming to IS:3589 of 200mm dia and thickness 8mm including two coats of anti corrosive bituminous paint of approved brand complete all as specified and directed. 60 All as per Srl Item No. 16.41 here-in-above but slotted pipe as per IS: 8110 strainer complete all as specified and directed. 61 S & F of end cap of for 200mm dia MS pipe, complete all as specified and directed. 62 S & F of MS reducer socket of 250x200 mm dia to be fabricated out of 12 mm sheet plate with the housing pipe of 250 mm dia for fixing 250 mm dia MS pipe to 200 mm dia MS pipe, complete all as specified and directed. 63 S & F of well cap of for 250mm dia MS pipe complete all as specified and directed. 64 S & F of clamp of size 150mmx10mm of length 1.5mtr including MS nut bolts of 10mm dia and washer etc for supporting casing pipe complete all as specified and directed. 65 S & F of clamp of size 150mmx10mm of length 1.0 mtr including MS nut bolts of 10mm dia with washer etc for supporting column pipe complete all as specified and directed. 66 S & F Steel wire rope, PVC insulated of size 10 mm dia of suitable size/ length as directed with clamps, nuts & boltsand washers etc for holdingcolumn pipes/GI pipes of submersible pump set, complete all as specified and directed. 67 S & F of cage fabricated from strips of size 25x4suitable for protection of submerssible pump set with two coat of anti corrosive black bituminous paint, complete all as specified and directed. 68 S & F of flat submersible cable 3 coremulti stranded copper conductor of size 6 sqmm ISI marked, complete all as specified and directed. 69 Supply and filling pebels of size 6 to 10mm around the casing pipe of borewell including all lead and lifts free from dust dirt or vegetation manure, complete all as specified and directed. 70 Development of tube well with compressed air and after with 25% extra capacity pump by pumping muddy water of borewell using air compressor of 350psi , 600cfm pressure for required number of hours including fuel etc.,complete all as specified and directed. 71 Conducting following tests for the bore well to determine safe water pumping from government approved laboratory including submitting the report to the department, complete all as specified and directed :-(i) Yield Test(ii) bacteriological Test(iii) chemical test (systematic analysis) 72 S & F of FASD submerssible motor panel starter of capacity 7.5 HPincl overload,single phasing prevention, complete all as specified and directed. 73 Design, supply, installation, testing and commissioning Iron Removal/ water treatment Plant of capacity 40 Cum/Hr (8000 GPH) complete to achive the permissible parameters of of treated waterconsisting of 01 set multi grade filter, 01 set Oxidation Chamber, 01 Set of Chemical Dosing System for Soda Ash, 01 Set ofChemical Dosing System for Sodium Hypo-chloride. The plant incld allinterconnecting piping valves & other accessories incld necessary internal cabling, termination support stays, clamps, inlet & outlet pipe connection for filtration and back wash etc confirming to relevant IS, foundationworks as per OEM. The plant to be painted with 2 coats of non-toxic anti-corrossive epoxy paint (suitable for drinking water quality) inside and 2 coats of synthetic enamel over a coat of red oxide primer complete comprising of the followings :- Item Continued as 16.43 to 16.46 74 (a)Oxidation Chamber, vertical cylindrical type, fabricated vessel of suitable size as per IS-2062, incld pipe line 100 mm dia, butterfly valve of suitable size incld 2 nos. pressure gauge ,sampling cocks filled with Oxidation Chamber. Theshell thickness shall be of 6 mm and dished end having 6mm and bed plate under drain collecting system will be strainer on bed plate. Diameter of vessel shall be - 900MM and Height on Straight - 750MM. (Necessary Civil work, foundation, PCC, RCC, excavation , returning and filling etc shall be deemed included in the quoted rate). - 01 Set 75 (b)Multi Grade Filter, vertical cylindrical type , MS fabricated vessel of suitable size as per IS-2062, incld pipeline 150 mm dia, butterfly valve of suitable size incld 2 nos. pressure gauge, sampling cocks filled with Sand media having 915 mm media depth. The shell thickness shall be of 6mm and dished end having 6mm with header and lateral collecting system. Multi Grade filter should have Epoxy paint from inside and outside red oxide paint. The shell shall also be provided with adequate size of air ventline with valve etc. Diameter of vesselof MGF shall be - 2000 MM and Height on Straight - 1875MM. (Necessary Civil work, foundation, PCC, RCC, excavation , returning and filling etc shall be deemed included in the quoted rate). - 01 Set 76 (c) Chemical Dosing System (CDS-4 with High Speed Agitator ) for Soda Ash at raw water collection tank with electromagnetic metering run on 220 V AC for 100% accurate dosing with all electrical connections with 200 ltrs PVC tank- 1 No. (Necessary Civil work, foundation, PCC, RCC, excavation , returning and filling etc shall be deemed included in the quoted rate).- 01 Set(d) Chemical Dosing System (CDS-4 with High Speed Agitator) for Sodium Hypo-chloride after iron Removal Plant with electromagnetic metering pump run on 220 V AC for 100% accuratedosing with all accessories with 200 ltrs PVC tank- 2 Nos. (Necessary Civil work, foundation, PCC, RCC, excavation , returning and filling etc shall be deemed included in the quoted rate).- 01 Set 77 Note :- (i)Minimum working pressure of the plant shall be- 2 Kgs/Sqcm Maximum working pressure of the plant shall be - 3.5Kgs/Sqcm(ii) Backwashing shall be 30 minutes at an interval of 8 hrs.(i) Contractor has to carry out necessary water testing and design of the plant accordingly. Chemical / bacteriogical test of water has to be recorded and submitted by the contractor before & after filteration. (ii)All necessary pipes, flange, fittings, valves for bypass pipe line connection, and inter connetion the plantdeemed to be included to the quoted rate. 78 Supply, installation, testing and commissioning multi stage submersible pump setwith bronze impeller, directly coupled with motor, suitable for 200/250 mm bore well water lubricated against minimum total head 45 meter and discharge min 600 LPM operated on AC 3 phase, voltage range 200V-440V, 50 Hz. The motor casing shall be of stainless steel, pump shaft/ motor shaft shall be of stainless steel, pump bowls shall be of high graded cast iron all as specified and directed. The pump and motor shall comply to all the requirements of relevant IS. NOTE :The pump size, i.e head and discharge mentioned is minimum required at site, however, the actual size shall be arrived after doing necessary yield test. 79 Supply,installation, testing and commissioning open well Submersible pump of capacity 10 HP,electric driven 415 V, TPand completeinclusive ofsubmersible cable and starter including dry run preventor and single phasing preventor complete all as specified and directed. 80 M&L for DI fittings for spigot and socket pipes of size 80 mm to 350 bore such as bends(any type,radius and angle) tapers any type (straight, bend, increasing,decreasing or double socket etc)Tee pieces single branch, Yjunction, double branch, cross(all sockets or socket and spigot) collars caps and plugs complete all as specified and directed. 81 FIRE FIGHTING & FIRE ALARM SYSTEMSupply, installation, testing, and commissioning of Fully automatic DOL starter, suitable for the booster pump, complete with contactors, push button, LED type indicators, auto/manual selector switch, overload protection, current sensing type single phase preventer complete with all accessories and wiring etc.with ncomplete all as specified and directed. 82 M & L for 2 core, 2.5 sqmm (for instrumentation)low smoke zero halogen (LS0H) flame retardant Fire alarm cable, conforming to BS 7629-1, BS 6387 & BS EN 50200 and rated for 500 V, drawn through concealed PVC conduit and having plain annealed stranded copper conductor with primary insulation of glass mica Fire resistant tape and secondary insulation of high performance silicone rubber, earth/drain wire of annealed tinned copper, electrostatic screen of aluminium fire barrier and type LTS3 outer sheath conforming to BS 7655, suitable for operating temperature range -30 ˚C to +70 ˚C and minimum bending radius being 6 times the overall cable diameter, RED in colour, including laying, termination and ferruling complete all as specified and directed. 83 M & L for 3 core, 2.5 sqmm (for auto start/stop panel)low smoke zero halogen (LS0H) flame retardant Fire alarm cable, conforming to BS 7629-1, BS 6387 & BS EN 50200 and rated for 500 V, drawn through concealed PVC conduit and having plain annealed stranded copper conductor with primary insulation of glass mica Fire resistant tape and secondary insulation of high performance silicone rubber, earth/drain wire of annealed tinned copper, electrostatic screen of aluminium fire barrier and type LTS3 outer sheath conforming to BS 7655, suitable for operating temperature range -30 ˚C to +70 ˚C and minimum bending radius being 6 times the overall cable diameter, RED in colour, including laying, termination and ferruling complete all as specified and directed. 84 S & F of orifice plate made out of 6 mm thick SS 304 with orifice of required size to be fitted between flange and landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete all as specified and directed. 85 S & F ofCL 150 # rated ball valve25 mm NB, designed & manufactured as per IS 9890: 1981 and tested as per BS 6755-1, having floating type three piece design, CS body, SS- 304 ball, PTFE seal / packing / gasket, CS fastners and lever and screwed / socket weld end connection, etc. with accessories complete all as specified and directed. 86 S & F ofCL 150 # rated ball valve80 mm NB, designed & manufactured as per IS 9890: 1981 and tested as per BS 6755-1, having floating type three piece design, CS body, SS- 304 ball, PTFE seal / packing / gasket, CS fastners and lever and screwed / socket weld end connection, etc. with accessories complete all as specified and directed. 87 M & L for FM approved and UL listed, PN 1.6 rated lever operated, wafer type CI butterfly valve, 100 mm NB, conforming to IS 13095: 1991,fitted with visual indicator & temper switch, having Cast iron (CI) body with ductile iron EPDM coated disc, SS431 stub shaft, PTFE bushing, flange drilling standard end connection conforming to IS: 1538- 1993 along with necessary accessories complete as specified and directed by the engineer-in-charge (for Zone control valve assembly). 88 M & L for FM approved and UL listed 25 mm NB compact 3 position ball valve with drain orifice (Test and drain valve) to test and drain water flow through sprinkler systems having OFF-TEST-DRAIN position, integral sight glass, rated pressure 300 psi, orifice size 15 mm and K factor 5.6, conforming to NFPA 13, along with necessary accessories complete as specified and directed. 89 S & F 6 kg capacity dry chemical powder (ABC) type fire extinguisher, conforming to IS 15683: 2006, with initial filling in brand new cylinder with powder coated finish, fitted in gunmetal union, high pressure CO2 gas cartridge, discharge hose, wall mounting bracket / floor trolley mounting accessories along with suitable signage, etc. complete all as specified and directed by the engineer-in-charge. NOTES: [i] Operating temperature :-300C to + 550C[ii] Performance criteria : Discharge time not less than 45 sec , throw not less than 4 meters[iii] Hydro test and burst pressure test : Shall pass hydro test pressure of 35 bars 2.5 minutes and with stand a burst pressure of 55 bar 90 S & F of the following type of signages made out of 3 mm thick opaque PVC foam board with computer cut, PVC non-reflective self adhesive vinyl painted foam board, complete with mirror fasteners as specified and directed:-Item Continued as 16.60 & 16.61 91 Sign of size 250 mm X 300 mm reading IN CASE OF FIRE, USE STAIRS UNLESS INSTRUCTED OTHERWISE in 12.5 mm block letters in red and white background, properly spaced to provide good legibility located directly above the call-button and squarely attached to the wall or partition in a way that the top of the sign is not above 2 m from the finished floor level. 92 Sign of size 150 mm X 600 mm, posted and maintained at each lift landing and on the side of the stairway door from which egress is to be made on every floor, indicating the lift / lift bank / stairway by an alphabetical letter in bold type and at 75 mm high letters in red and white background, securely attached to the side of the stairway door from which egress is to be made in a way that the bottom of the sign is not above 1.5 m from the finished floor level. 93 S & F Galvanised Iron Fire bucket 9 ltr Red in colourheavy duty all as specified and as directed 94 EXTERNAL ELECTRIFICATIONS & L 50 mm outside dia double corrugated pipe(DWC) ISI marked for enclosing cable below ground/road surface to a required depth including suitable size couplers for jointing of pipe all as per site requirement etc complete all as specified and directed. 95 S & L 75 mm outside dia double corrugated pipe(DWC) ISI marked for enclosing cable below ground/road surface to a required depth including suitable size couplers for jointing of pipe all as per site requirement etc complete all as specified and directed. 96 S & L 90 mm outside dia double corrugated pipe(DWC) ISI marked for enclosing cable below ground/road surface to a required depth including suitable size couplers for jointing of pipe all as per site requirement etc complete all as specified and directed. 97 Design, Manufacturing, Supply, Installation, Testing and Commissioning of 3 way 12 kV rated Ring Main Unit ofand LT Fault Level 21KA , consisiting of 630A12 kV rated , 1 nos load break switchesas incomers &2 nos motorized type VCB as outgoings with metering modules along with necessary Earth Switches,battery and battery charger for shunt trip arrangement andMotor and other auxiliary circuit operation, HT CopperBus bar as per detailed description as follows:- Item Continued as 16.67 to 16.74 98 RMU Construction: The switchgear and busbar shall all be contained in a stainless steel enclosure filled with SF6 at 0.3 bar (300 hPa) relative pressure to ensure the insulation and breaking functions. Sealed for life, the enclosure shall meet the sealed pressure system criterion in accordance with the IEC 62271-1 standard (§ 3.6.5.4): a volume for which no further gas processing is required during its entire expected life”. In addition, manufacturer shall confirm that maximum leakage rate is lower than 0,1 % / year. It shall provide full insulation, making the switchgear insensitive to the environment (temporary flooding, high humidity...), IP67 degrees of protection in accordance with recommendation IEC 60529 § 14.2.7. Thus assembled, the active parts of the switchgear shall be maintenance-free and the switchboard shall be low-maintenance. The switchboards drives shall have an IP2X protection index. The tank shall be made of at least 2mm unpainted stainless steel.SF6 gas is the preferred dielectric medium for MV RMUs. Oil filled switchgear will not be considered.SF6 gas used for the filling of the RMU shall be in accordance with IEC 60376.Any accidental overpressure inside the sealed chamber will be limited by the opening of a pressure limiting device in the lower part of the enclosure. Gas will be released to the rear or the bottom of the switchboard away from the operator. Number of mechanical operations of Circuit breaker 2000 O/C , Number of electrical operations at full loop current for LBS: 100 O/C , Number of electrical operations at full loop current for CB: 2000 O/C,. Manufacturer shall provide type test report to prove compliance with IEC 62271-200 Annex A, Internal arc classification class AFL with 21kA 1s for the SF6 enclosure. Make of the RMU, vaccum intrtupter , relay & meter shall be of same OEM. All the test certificate shall be in the name of the OEM only . If there is any name change / acquisition by other OEM happened for the RMU then test cerificates shall contain the new OEM name only. 99 HT system : 3 phase -3 wire , HT Fault level21 kA, Power System earthing - solindly earthed at up stream source, HT Copper Bus with Short Time Curent rating 21 kA for 1 Sec ( 3Sec), Continuous current rating at least 630 A. Enclosure of RMU must be IAC rated for 21 kA for 1 Sec. Design ambient to be considered as 40 Deg C.HT Circuit Breaker : i) There shall be 1nos.load break switches as incomings and 2 nos 12 kV rated VCBas outgoing ( total 3 nos.) . The circuit breakers shall behorizontal isolation - horinzontal draw out type. All of the switchgear shall be capable of withstanding this current without any damage being caused, in accordance with the recommendations IEC 62271-1 and IEC 62271-200.Loss of service continuity class: LSC2Aii) The Circuit Breaker must be rated for 12 kV ( nominal Voltage), 28 kV/75 kVp ,3 Phase, 50 Hz, Short Circuit Fault Level of 21 kA for 1 secs. Iii) No. Of Close Coils - 01 no. operable at 24 V DC (85% - 110%) , No. of Trip Coils - 02 nos. ,operabale at 24 V DC ( 70% - 110%) for shunt trip Feature forseries trip shall also be enabled. iv) Provision for supervision of the two indepandent Trip Circuits for the two Trip Coils to be provided. v)Switchgear classification: PM classvi) Loss of service continuity class: LSC2A 100 vii) Duty Cycle : O – 0.3sec – CO – 3min – CO, Vacuum Circuit breaker shall be of M2, E2, C2 duty and capable for minimum 100 short circuit breaking operation at full short circuit level.viii) STC rating 21 kA for 1 Sec (for Vacuum Interrupter).ix)Vacuum Interrupter must be hermetically sealed and must comply IEC 60056 ( along with latest amendments). x)Circuit Breaker to be equipped with Suitable tripping arrangement with push button, Mechanical counter to assess the total number of operations of the breaker, Mechanical ON / OFF indicator, Auxiliary switches, Auxiliary Contacts( at least 2 NO + 2 NC of Class 2 category), Emergency trip push button.xi) The Operating mechanism shall be spring charged motor operated type with Spring Charge Universal motor operable on 24 V DC / 230 V AC.xii)Suitable monitoring of Circuit Breaker status ( ON, OFF, Trip, CB Spring Charged), Trip Circuit Healthy / Unhealthy, DC healthy/unhealthyto be provided using IoT based online monitoring system using microprocessor / digital RTU with historical data saving, capable of updating status and sending alarm signal on IoT monitoring unit, GSM and GPRS platform through which live monitoring status and equipment reading and fault related history can be accessed by user remotely. 101 xiii) Voltage Presence Indicator shall be provided against each HT circuit ( against each VCB) on line side for knowing the presence of line enerzisation status.xiv)Number of Mechanical operations at full rated current for breaker: 2000 O/CHT CT /PT i) One set of 03 nos. ( for 3 phases) dual core Cast Resin CTs for Eachincomer VCBcomplying with IEC:60185 & IS 2705 ( along with latest amendments) , Core -1 - 400-200/1 A , 15 VA, Cl 0.5 for metering ; Core-2 - 400-200/1 A, 15 VA , 5P10 for Protection.ii) 01 no. of 03 phase Dual Core PT forHT bus ( 11 kV)with protection HRC fuseCore 1- 11kV-6 kV /√3 / 110V/√3, Cl 0.2s, 100VACore 2- 11kV- 6 kV /√3 / 110V/3, Cl 3P, 50VA 102 Multifunction Meteriii) 2 Nos. 3 phaseDigital Multifunction Meter6400NGwith Voltage, Amps, kWh, kW, P.F., Active, reactive, apparent energy , disturbance direction detection, Individual harmonic up to the 63rd harmonic. at least 256 samples/cyclewith ethernet Port with inbuilt webserver and complying to IEC 61557-12, IEC 62053-22 certified by third party laboratory.for each VCB panel ( 96 mm x 96 mm) , Flush mounted, Class 1 conforming to IEC 62053-22 ( along with latest amendments) .Protection Relayi) 2 Nos. of Numerical Type IDMT Relay (50/51, 50N/5IN) with two elements for overcurrent and earth fault having settings 50% to 200% for overcurrent and 20% to 80% for earth fault in equal steps with time and current settings and high set instantaneous unit. Additionally, condition monitoring CB wear, condition monitoring CT supervision, disturbance recorder, undervoltage & over voltage protection, trip circuit supervisioncan be measured through the relay. The device shall support webserver/web HMI through which we can monitor and control the relays over a ethernet Lan network. Licenses for theprogramming software shall be provided free of cost.The numerical relay shall have large mimic-based LCD screen display . .The relay shall have 8 Digital inputs and 8 Digital Outputs and one additional watchdog ouput.The device has to aloe controlling of min. six objects (circuit breakers, disconnectors and grounding switches). Controlling has to be done by “select-execute” or “direct control” principle. Controlling has to be possible by: through local HMI, remote communication, via digital input or via function key. Events has to be readable to SCADA systems, front panel or by setting software.The sample rate of the recording has to settable to 32samples/cycle.The devices shall provide storage up to events 2000 based on the resolution.The device shall support following communication protocols: Native IEC 61850 ed1 & ed2, Modbus TCP. The IEC 61850 communication has to support peer to peer communication (GOOSE) if requiredThe IEC 61850 interface must be able to configure through setting software. Also the same setting software has to be able to generate ICD filesThe device shall have KEMA IEC61850 edition 2 certificates. 103 ii) Master Trip Relay :High Impedance and High speed relay flush mounted having coil cut-off contact with at least 4NO and 4NC contact and electrical reset facility capable to make, carry and break trip coil current of Circuit Breaker and capable for future integration with SCADA.iii) Each VCB must have separate Anti Pumping Relay.Fault Passageindicator: 104 The FPI shall facilitate quick detection of faulty section of line. The fault indication may be on the basis of monitoring fault current flow through the device. The FPI should be self-powered and should have internal lithium battery for external indication and setting of FPI in the absence of current.The FPIs shall include:Fault detection - Phase to phase and Phase to earth faults.One potential-free output contacts for hardwiring to RTUs. On this basis, the SCADA/DMS will be able to monitor phase / earth fault condition.Local fault indications - LCD display on FPI front panel along with LED indication on front panel of RMU enclosure.Multiple reset option –End of time delay (Adjustable from 2 to 16 Hrs)Remote reset (Via potential free input contact of FPI)Manual reset (Reset button on front panel of FPI)Automatic reset on current restoration.The characteristics of the FPIs shall include:Phase fault thresholds configurable from at least 100 to 800 AEarth fault thresholds configurable from at least 20 to 200 AMultiple number of steps for adjusting phase and earth fault thresholds.Fault current duration range configurable from at least 40 ms to 100 ms in 20 ms steps and further 100 ms to 300 ms in 50 ms steps. Variations with respect to these characteristics may be acceptable as long as they prove applicable and provide the same or better flexibility. 105 Earthing The cables shall be earthed by an earthing switch with short-circuit making capacity, in compliance with IEC 62271-102 standard. The earthing switch can only be operated when the switch is open. The switch and earthing switch operating mechanism shall have a mechanical endurance of at least 1000 operations.Separate line side Earth switches shall be provided in each HT Circuit ( against each VCB)RMU Bushing & Cable termination:It is preferable to have all bushings accessible from the front of the RMU. Bushings along the sides or the rear of the RMU are not acceptable.For each cable compartment, the bushing shall be at the same height in order to facilitate a possible reversal of the cablesThe bushing should be conveniently located for working with cables specified and allow for the termination of these cables: -630 A M16 bolted connectors for switch-disconnectors and vacuum circuit breakers functions.The profiles of the cable connection bushings shall be in compliance with IEC-60137 standard.Cable clamps:A cable clamp arrangement must be provided for all network cables terminated on the RMU. Provision for Cable Entry: There shall be suitable provsion for Cable entry from bottom through 3 mm thick CRCA steel thick detachable gland plate along with provision for termination of 2 runs of 3 c X 400 Sq mm 11 kV (E ) , XLPE insulated Aluminium Cables ( for HT side) and at LT side runs of cables matching with outgoing MCCB current rating. 106 S&F 8.0 Mtr Long Hot Dip Galvanised Street Light Octagonal Pole with Foundation type Base Plate and Foundation Bolts and additional structural steel as reqd, dimentions of Pole as Top Diameter - 70 mm, Bottom Diameter- 130 mm, Section Length - 8000 mm, Thickness - 3 mm, Foundation type Base Plate (200 x 200 x 16 mm), Foundation Bolts - 4 Nos 20 mm dia, pitch circle dia 200 mm, bolt length 600 mm, projects bolt length 100 mm , with Single type arm bracket 1500 mm long , top dia 70 mm , suitable for LED Street Light fitting. The Pole shaft shall have octagonal cross section and continuously tapered with single longitudinal welding all as specified and as directed. 107 M&L for water proof, 3core PVC insulated and PVC sheathed, copper conductor cable of size 1.5 sqmm, 1100 Volts grade for electrical connection of street light fittings, complete all as specified and directed. 108 S&F factory made IP-65 (Dust and power jet Proof according to IEC 60529) opaque street light junction box of size 260 mm x 210 mm x 116mm made of high quality polycarbonate (shock proof, rust free, corrosion free acid and chemical resistant, fire retardant having high impact(IK 08) totally insulatedmade of halogen and silica free recyclable material, UV resistant having high grade gasket made of polyurethane with copper terminal , MCB SP 6 Amps rating 10 KA with locking arrangement and 2 Nos M40 size cable glandand one M32 size gland suitable up to 35 Sqmm cable etc complete all as specified and directed. . 109 S&F HT/LT made up of PCC block (1:3:6) type. C-1 using 20mm graded stone aggregated of size 900 mm x 300mm x 100 mm thick (45 Cm burried in ground) and properly painted as per approved colour Brown/Blue (HT/LT) and written both side with signed red colour paint( HT cable 11 KV orLT cable 1100 Volts) on Cable route marker including necessary excavation and earthwork complete all as specified and directed. 110 Supply, installation, testing and commissioning outdoor type stainless steel (SS 304) cubical enclosure compartmentalizedexterior and interior mirror type brushed suitable for highly corrosive environment, high creep resistance, better mechanical properties like ductility, yield strength, hardness etc. The enclosure shallbe made of 2 mm thickSS 304 sheet. The fixing of doubledoors shall be on SS hinges with anti-theft provision (the door can’t be removed from enclosure without cutting enclosure). All fabrication/welding shall be done with TIG/MIG or as approved by Engineer in charge suitable for SS 304.Sliding handle and locking arrangement front and rear both side . Enclosure shall be suitable for AC supply system 415 volts, 3 phase, 4 wire, 50 Hz. IP-55 class protection and mounted on channel 75 mm welded with panel of SS 304 with 04 Nos foundation bolt of size not less than20mm dia and 300mm long. The enclosure shall have provision of cable alley . Cable entry from bottom side including internal wiring with PVC insulated solid, copper conductor FRLS cable, IS-694 marked,1100 volts grade of appropriate size (but not less than 2.5 sqmm).Incoming :-(i) Aluminium busbar rating 600 Amps rating 4 Nos. (ii) MCCB 400 Amps 4 pole breaking capacity 36 KA thermal mag protection with Icu = 100% & rated impulse with stand voltage (Vimp) 8 KV with over current & short circuitpro-tection having double insulation & positive insulation-01 No.Outgoing :-(i) MCCB 400 Amp 4 pole 01 Nos breaking capacity 36 KA , MCCB 63 Amp 4 pole 02 Nos breaking capacity 16 KA,, thermal magnetic release with Icu = 100% & rated impulse with stand volta.(Vimp) 8 KV with over current & short circuit protec-tion having double insulation & positive insulation featers. MCB SPN 32 Amp02 Nos. Item Continued as 16.80 111 (ii) Current transformer 100/5Amps class-1 15 VA - 1 Nos, Digital Ammeter with inbuilt selector switch -01 No, Digital Voltmeter with in built selector switch -01 No and Modular Indication lamp for main incomer LED type RYB (set of 3)-1 Set All MCCB with adjustable protection for over load and short circuit and conforming to IEC60947-II/IS 13947-II (Latest Version). The MCCB should have Ics=100%Icu. The MCCBs shall have spreader links and barriers as standard feature of manufacturer. All out going feeder shall be connected by cable through suitable size gland plate / glands.The various feeders shall be indicated by font size not less than 20 mmletters using Acrylic sheet. The minimums clearance of bus bar shall be 32mm phase –phase and 26mm for phase to earth. The bus bar shall have colour coding with insulating tape.Platform for the panel with PCC 1:4:8 type D-2 with 40 mm graded crushed stone, 15 cm thick in foundation, brick work in CM 1:6 with sub class B, old size bricks, rendering 15 mm thick in CM 1:6 on exposed surfaces and 100 mm thick PCC padding 1:3:6, type C-1 using 20 mm graded crushed stone aggregate on top and grouting bolts etc for panel.The platform shall be such that it is of a height 45 cm above the nearest road level. 112 Supply, installation, testing and commissioning outdoor type stainless steel (SS 304) cubical enclosure compartmentalizedexterior and interior mirror type brushed suitable for highly corrosive environment, high creep resistance, better mechanical properties like ductility, yield strength, hardness etc. The enclosure shallbe made of 2 mm thickSS 304 sheet. The fixing of doubledoors shall be on SS hinges with anti-theft provision (the door can’t be removed from enclosure without cutting enclosure). All fabrication/welding shall be done with TIG/MIG or as approved by Engineer in charge suitable for SS 304.Sliding handle and locking arrangement front and rear both side . Enclosure shall be suitable for AC supply system 415 volts, 3 phase, 4 wire, 50 Hz. IP-55 class protection and mounted on channel 75 mm welded with panel of SS 304 with 04 Nos foundation bolt of size not less than20mm dia and 300mm long. The enclosure shall have provision of cable alley . Cable entry from bottom side including internal wiring with PVC insulated solid, copper conductor FRLS cable, IS-694 marked,1100 volts grade of appropriate size (but not less than 2.5 sqmm).Incoming :- (i) Aluminium busbar rating 600 Amps rating 4 Nos. (ii) MCCB 400 Amps 4 pole breaking capacity 36 KA thermal mag protection with Icu = 100% & rated impulse with stand voltage (Vimp) 8 KV with over current & short circuitpro-tection having double insulation & positive insulation-01 No.Outgoing :-(i) MCCB 100 Amp 4 pole 03 Nos, MCCB 63 Amp 4 pole 02 Nos breaking capacity 16 KA, MCCB 40 Amp 4 pole 01 Nos breaking capacity 16 KA thermal magnetic release with Icu = 100% & rated impulse with stand volta.(Vimp) 8 KV with over current & short circuit protec-tion having double insulation & positive insulation featers. (ii) Current transformer 100/5Amps class-1 15 VA - 1 Nos, Digital Ammeter with inbuilt selector switch -01 No, Digital Voltmeter with in built selector switch -01 No and Modular Indication lamp for main incomer LED type RYB (set of 3)-1 Set Item Continued as 16.82 113 All MCCB with adjustable protection for over load and short circuit and conforming to IEC60947-II/IS 13947-II (Latest Version). The MCCB should have Ics=100%Icu. The MCCBs shall have spreader links and barriers as standard feature of manufacturer. All out going feeder shall be connected by cable through suitable size gland plate / glands.The various feeders shall be indicated by font size not less than 20 mmletters using Acrylic sheet. The minimums clearance of bus bar shall be 32mm phase –phase and 26mm for phase to earth. The bus bar shall have colour coding with insulating tape.Platform for the panel with PCC 1:4:8 type D-2 with 40 mm graded crushed stone, 15 cm thick in foundation, brick work in CM 1:6 with sub class B, old size bricks, rendering 15 mm thick in CM 1:6 on exposed surfaces and 100 mm thick PCC padding 1:3:6, type C-1 using 20 mm graded crushed stone aggregate on top and grouting bolts etc for panel.The platform shall be such that it is of a height 45 cm above the nearest road level. 114 Supply, installation, testing and commissioning indoor type stainless steel (SS 316) cubical enclosure compartmentalizedexterior and interior mirror type brushed suitable for highly corrosive environment, high creep resistance, better mechanical properties like ductility, yield strength, hardness etc. The enclosure shallbe made of 2 mm thickSS 316 sheet. All fabrication/welding shall be done with TIG/MIG or as approved by Engineer in charge suitable for SS 316. Enclosure shall be suitable for AC supply system 415 volts, 3 phase, 4 wire, 50 Hz. IP-55 class protection and mounted on channel 75 mm welded with panel of SS 316 with 04 Nos foundation bolt of size not less than20mm dia and 300mm long. The enclosure shall have provision of cable alley . Cable entry from bottom side including internal wiring with PVC insulated solid, copper conductor FRLS cable, IS-694 marked,1100 volts grade of appropriate size (but not less than 2.5 sqmm).Incoming :- (i) Aluminium busbar rating 150 Amps rating 4 Nos. (ii) MCCB 63 Amps 4 pole breaking capacity 16 KA thermal mag protection with Icu = 100% & rated impulse with stand voltage (Vimp) 8 KV with over current & short circuitpro-tection having double insulation & positive insulation-02 No ( for incomer mains and incomer DG supply) (iii) Onload change over switch 63Amps modular type - 01 nos(Note: Busbar will be connected at changeover output)Outgoing :-(i) MCCB 32 Amp 4 pole 03 Nos breaking capacity 16 KA thermal mag protection with Icu = 100% & rated impulse with stand voltage (Vimp) 8 KV with over current & short circuitpro-tection having double insulation & positive insulation, MCB TPN 40Amps - 02 Nos, 3 Phase timer switch 40 Amps- 1 Nos(ii) Current transformer 100/5Amps class-1 15 VA - 2 Nos, Digital Ammeter with inbuilt selector switch -02 No, Digital Voltmeter with in built selector switch -02 No and Modular Indication lamp for main incomer LED type RYB (set of 3)-2 Set (at both incomer MCCB)Item Continued as 16.84 115 All MCCB with adjustable protection for over load and short circuit and conforming to IEC60947-II/IS 13947-II (Latest Version). The MCCB should have Ics=100%Icu. The MCCBs shall have spreader links and barriers as standard feature of manufacturer. All out going feeder shall be connected by cable through suitable size gland plate / glands.The various feeders shall be indicated by font size not less than 20 mmletters using Acrylic sheet. The minimums clearance of bus bar shall be 32mm phase –phase and 26mm for phase to earth. The bus bar shall have colour coding with insulating tape.Platform for the panel with PCC 1:4:8 type D-2 with 40 mm graded crushed stone, 15 cm thick in foundation, brick work in CM 1:6 with sub class B, old size bricks, rendering 15 mm thick in CM 1:6 on exposed surfaces and 100 mm thick PCC padding 1:3:6, type C-1 using 20 mm graded crushed stone aggregate on top and grouting bolts etc for panel.The platform shall be such that it is of a height 45 cm above the nearest road level. 116 SEWAGE TREATMENT PLANT (STP)Design, Supply, Installation, testing & commissioning of PACKAGED Sewage Treatment Plant(NBF Model)of capacity 50,000 Ltrs per Day with FRP Intermediate Cum Treated Water Tank of 20 KL capacity and tertiary treatment based on principle of aerobic attached growth non clogging randomly Moving Bed Bio-reactor (MBBR) complete with Recirculation Pump(Non clog submersible type of capacity 9 m3/Hr, Motor-1HP, Head- 8m) - 01 No,Air Blowers twin lobe type of capacity 3.0 HP - 02 Nos, Filter feed pump (Non clog submersible type of capacity 18.0 m3/Hr, Motor-1 HP, Head- 15 m) - 2 Nos ,Pressure Sand Filter FRP based complete with connection pipes (capacity-3.0 m3/Hr, Max Pressure- 10 PSI)- 1 NosActivated Carbon Filter FRP based complete with connection pipes (capacity-3.0 m3/Hr, Max Pressure- 10 PSI)- 1 NosChlorine Dosing Pump of capacity 0-6 LPH- 1 NosMCC Control Panel ,FRP tank accessories , including all connecting PVC pipes and all others accessories and necessary civil works for installation as per recommendation of OEM.Note:-(a)The minimum life of STP shall be 15 years. A certificate from manufacturer shall be provided by the contractor.(b)The RCC Collection Sump of suitable capacity before STP and necessary pumping arrangement (as required) is deemed to be included in the rate quoted by the contractor.(c)All accessories required to achieve the outlet parameter shall be included in the quoted rate.(d)Necessary arrangements to accomodate the inlet sewer Pipe line as per invert level deemed to be included in the quoted rate.(e)The contractor has to get the design and other parameters for complete sewage system including STP approved from GE before placing of order for procurement 117 COOLING APPLIANCESSupply , installation, testing & commissioning of refrigerator, ISI marked electric driven , single phase having capaciy 360 ltrs or nearest higher size , frost -free smoothflow type seprate chill compartment with plastic shelves, Ice maker unit, vegetable/fruit drawer, body colour as approved with suitable lighting arrangement working with non-CFC refrigerant & 3 star rated including electric connection complete all as specified and directed. 118 Supply , installation, testing & commissioning of refrigerator, ISI marked electric driven , single phase having capaciy 310 ltrs or nearest higher size , frost -free smoothflow type seprate chill compartment with plastic shelves, Ice maker unit, vegetable/fruit drawer, body colour as approved with suitable lighting arrangement working with non-CFC refrigerant & 5 star rated including electric connection complete all as specified and directed. 119 Supply,Installation, testing and commissioning of copper wound volatge stablizer , ISI marked for automaticoperation , single phase, naturally air cooled, indoor type & designed for I/P variation between 170 V to 260 V with O/P voltage stablization at 230 V with accuracy of +/- 2.5% with high & low voltage cut out & time delay & of capacity 01 KVA incl electric connection complete all as specified and directed. 120 Supply,Installation, testing and commissioning of copper wound volatge stablizer , ISI marked for automaticoperation , single phase, naturally air cooled, indoor type & designed for I/P variation between 170 V to 260 V with O/P voltage stablization at 230 V with accuracy of +/- 2.5% with high & low voltage cut out & time delay & of capacity 02 KVA incl electric connection complete all as specified and as directed 121 DG SETSupply, installation, testing and commissioning totally enclosed (silent operation with canopy, CPCB-IV+ complaint), static type deidel engine driven, liquied cooled, generating set of 30 KVA, 24KW capacity accommodated with accoustic encloser (at 0.8 lagging P.F), 415V,50Hz, 3 phase system & for 0.85 load factor , base plinth as per manufacturer recommendation, (A) Disel Engine:- Diesel engine shall be 4 stroke liquid cooled, electric start, of suitable BHP at 1500 RPM suitable for above output of alternator at ambient temp of 50 dgree celcius, 50% RH & 1000m above MSL, electronic governer, confroms to BS:5514/ISO 3046, BS 649,IS 10000 with capacity of 10% overload for one hour in every 12 hours of continuous operation. The engine shall have noise limit of 75 dB(A The OEM shall undertake type approval and conformity of production certificate for emission standard for engine from agencies approved by GoI. Copy of the same shall be produced,(A1) Air intake system(i) Air intake manifold,(ii) Dry type air cleaner(A2) Exhaust system(i) Dry exhaust manifold with residental silencer and catalytic converter(A3) Cooling system(i) Engine water pump(ii) Radiator with fan(iii) coolant additive concertrate(A4) Lubricant system (i) Oil pan(ii) Engine mounted lube Oil pump (iii) Lube oil filter(A5) Starting System,(i) 12/24 V DC starter motor, voltage regulatorsItem Continued as 16.91 to 16.94 122 (ii) 12/24 V DC alternator for battery charging, (iii) 12/24 V suitable maintenance free battery of suitable capacity(A6) Engine mounted microprocesser based (perferably) instrument panel with digital display for the following:-(i) LED indicating lamps-for Genret running, remote start, shutdown, warning, manual, auto and stop(ii) Data Logs-engine run time and controller on time(iii) Start/Stop switch with key(iv) Indication/Display of for water temp, lub oil pressure, lub oil temp, battery charging,RPM, over speed, low lub oil trip, Engine hours(v) Engine and alternator data - startingf batter voltage, Engine running hours, engine temp, engine oil pressure, alternator voltage, current, KVA, frequency, KWH shall be displayed.(B) protection to Genret, (i) Low lube oil pressure warning/shutdown, (ii) High engine temp warning/shutdown,(iii) Low coolant temp warning, (iv) Sensor failure indication,(v) Low/High battery voltage warning,(vi) weak battery warning, (vii) fail to start shutdown,(viii) Cranking lockout, 123 (ix)High/Low AC voltage shutdown,(x) under/over frequency shutdown,(xi) loss of sencing voltage shutdown.(C) Others(i) AVM Pads, (ii) First fill of lubricating oils(iii) flywheel with housing(iv) Residental silencer,(D) Alternator synchronous alternator copper wounded rated 30 KVA, 415 volts, 1500 RPM,3 phase,50Hz,AC supply with 0.8 lagging power factor at 50 degree c, 50% RH and at 500 MSL, brushless type, self exicited, SPDP encl , contineous duty, voltage regulated through AVR conforming to IS:4722 with class F/H insulation. The sailent feature are as under: (a) Permanent lubricating beraing (b) Permissible overloading of 10% for one hour in every 12 hrs of contineous operation (c) permissible unbalancing capability minimum 25% per phase .(E) ACCOUSTIC ENCLOSER FOR DG SET :-S & F accustic enclosers suitable for 30 KVA capacity diesel generator set duly fabricated of channel and CRCA sheet 2 mm of required size having doors , insulation sides and top by minral rock wool confirming to IS-8183 of adequate thickness accoustic louvers / outlet ventilation system etc. complete as per manufacturers instruction with wiring and lighting arrangments duky painted of three coats of delux gloss synthetic enamelled paint over a primer coat or as directed of suitable size all as requried at site and comprising of the following:- (i) Base: MS channel fabricate MS channel made out of 5 mm thick MS sheet of ISMC suitable section, (ii) Structure heavy duty rectangular MS box channel , (iii) Doors fabricated from MS CRCA 2 mm thick air tight with neoprene rubber gasket and gun metal heavy duty spring loaded locks, 124 (iv) Out side cover : Made out of 2 mm thick ,(v) Accoustic insulation(side & top) sound proffing mineral rock wool slab thickness 100 mm of density 96Kg/m3 confriming to IS 8183 , covered by fire resistant fiber tissue as per manufacturer recommendation. Test report from original manufacturer to be submitted before incorporation in the work authenticity of material, (vi) Inspection port : Aluminium frame with double walled glass fixed type sealed with neoprene rubber gasket for viewing instrument panel. (F) FOUNDATION :- PCC Foundation M 20 ( or as per manufacturere design ) , 450 mm overall height , 300 mm above floor level and 150 mm below floor level of requried size. The price of foundation of DG Set is included in quoted rate. (G) FUEL TANK:- One no of sheet metal steel tank made out of 3.0 mm thick MS sheet of suitable capacity of hold diesel sufficient for 12 hours running at full load , tank shall be fitted with incanopy as per manufacturers design including the following:- (i) Level indicator to indicate level of diesel in tank,(ii) Drain plug with 2.0 mtrs pipe for drain oil, (iii) fuel strainer, (iv) pipe for fuel,(v) air vent. 125 NOTE:- (a) Generating set will be placed on suitable foundation as recommended by manufacturer and cost thereof shall be included on the prices quoted. (b) Tools shall be supplied as per manufacturers instruction and cost therof shall be included in the price quoted. (c) DG Set shall be placved at the site directyed by Engr-in-Charge. (d) Testing of DG Set shall be done as per relivant IS clause or min 10 hour running with 01 hour with no load, 02 hr with 25% load, 02 hrs with 50% load, 02 hrs with 75% load, 02 hrs with 100% load, 01 hr with 110% load. The required Fuel and artificial load/tools, etc to be included in quoted rate. 126 DEMOLITION & DISMANTLINGTaking down carefully old unserviciable DB including of any size/way complete including MCBs for keeping in safe custody or for taking credit all as directed. 127 Taking down carefully old unserviciable service cable of any size for keeping in safe custody or for taking credit all as directed. 128 Taking up or down from any position existing CI water tubing and connections carefully or for taking credit complete all as specified and as directed for 100 mm size 129 Taking up or down from any position existing CI water tubing and connections carefully or for taking credit complete all as specified and as directed for 100 mm size 130 Taking down carefully old unserviciable sluice valve 100 mm for keeping in safe custody or for taking credit all as directed. 131 Taking down carefully old unserviciable sluice valve 150 mm for keeping in safe custody or for taking credit all as directed. 132 Taking down carefully old unserviciable gate valve 25 mm for keeping in safe custody or for taking credit all as directed.
Contract Date: Feb 12, 2026 Contract Value : 39.08 Crore
Statutory Bodies & Commissions/Committees No of Bidders 9
West Bengal View Result →
15.
Agriculture #9567643 Technical Bid
Tender For Supply Of Tools/ Diagnostic Devices/ Workshop Equipments/ Spare Parts To Farm Machinery Clinic, Kollam. (Annual Plan 2025-26 - Support To Farm Mechanization) , Part 1-Hand Tools , Mechanic Tool Set Supplying A Comprehensive Professional-Grade The Mechanics Tool Kit With A Durable, Impact-Resistant Moulded Suitcase (Bmc Case) With Designated Compartments For Each Component, Ensuring Easy Portability And Organization And Includes The Chrome-Vanadium Tools And Accessories Listed As Appendix 1 1. 1/2 Drive Set A) Hexagonal Socket (19 Pcs) - Sizes: 8, To 32 Mm B) Star Socket (5 Pcs) - Sizes: E10, E12, E14, E16, E20 C) Flex Handle (1 Pc) - Length: 375 Mm D) Ratchet Wrench (1 Pc) - 1/2 Drive, 45 Teeth (Reversible) E) Extension Bars (2 Pcs) - Lengths: 75 Mm (3), 250 Mm (10) F) Universal Joint (1 Pc) - 1/2 Drive G) Three-Way Adaptor (1 Pc) - 1/2 Female × 3/8 Male H) Spark Plug Sockets (2 Pcs) - Sizes: 16 Mm And 21 Mm I) L-Handle (1 Pc) - 1/2 × 10 2. 3/8 Drive Set A) 12-Point Socket (15 Pcs) - Sizes: 6, To 22 Mm B) Ratchet Wrench (1 Pc) - 3/8 Drive, 45 Teeth (Reversible) C) Extension Bars (2 Pcs) - Lengths: 75 Mm (3), 150 Mm (6) D) Universal Joint (1 Pc) - 3/8 Drive 3. 1/4 Drive Set A) Screwdriver Bits (26 Pcs, 25 Mm Length, S2 Steel) B) Phillips (Ph): Ph0, Ph1, Ph2, Ph3 C) Pozidriv (Pz): Pz0, Pz1, Pz2, Pz3 D) Slotted (Sl): Sl4, Sl5.5, Sl7 E) Hex (H): H2, H3, H4, H5, H6, H7, H8, H10 F) Torx (T): T10h, T15h, T20h, T25h, T27h, T30h, T40h G) Bit Holder (1 Pc) - 1/4 Hex H) Hexagonal Sockets (9 Pcs) - Sizes: 4, 4.5, 5, 5.5, 6, 7, 8, 9, 10 Mm I) Star Sockets (5 Pcs) - Sizes: E4, E5, E6, E7, E8 J) Ratchet Wrench (1 Pc) - 1/4 Drive, 45 Teeth (Reversible) K) Extension Bars (3 Pcs) - Lengths: 50 Mm (2), 100 Mm (4), 150 Mm (6) L) Universal Joint (1 Pc) - 1/4 Drive M) Three-Way Adaptor (1 Pc) - 3/8 Female × 1/4 Male N) Spinner Handle (1 Pc) - 1/4 × 150 Mm O) Flexible Extension Bar (1 Pc) - 1/4 × 150 Mm 4. Combination Spanners (17 Pcs) - Sizes: 6, To 24 Mm 5. Flare Nut Spanners (5 Pcs) - Sizes: 8×10, 10×12, 11×13, 12×14, 17×19 Mm 6. Hex Key Set (10 Pcs) - Sizes: 2.5, 3, 4, 5, 6, 7, 8, 10, 12, 14 Mm 7. Machinist Hammer (1 Pc) - 300 G With Fiberglass Or Wooden Handle 8. Combination Pliers (1 Pc) - 7 9. Locking Pliers (1 Pc) - 10 Curved Jaw Lock Wrench 10. Slotted Screwdrivers (2 Pcs) - Sl6.5 × 100 Mm And Sl6.5 × 150 Mm 11. Phillips Screwdrivers (2 Pcs) - Ph2 × 100 Mm And Ph2 × 150 Mm 12. Stubby Screwdrivers (2 Pcs) - Ph2 × 38 Mm And Sl6.5 × 38 Mm All Sockets, Spanners, And Ratchets Shall Be Made From Chrome Vanadium Steel (Cr-V), Heat-Treated, And Chrome-Plated For Corrosion Resistance. Screwdriver Bits Shall Be Of S2 Alloy Steel For High Torque Resistance. Ratchets Shall Have A Minimum Of 45 Teeth With A Quick-Release And Reversible Mechanism. All Tools Shall Conform To Din / Iso Standards Or Equivalent. Suitcase Colour Should Be Standard Industrial Colour (Black / Blue / Grey Or Similar)- Preferably Tapariya Or Eastman , Tee Spanner Set Including Spanners Ranging From 8 Mm To 19 Mm Made From Chrome Vanadium Steel (Cr-V), Hardened And Tempered For Durability, The Handle Shall Be T-Shaped, Providing Maximum Torque And Grip And Surface Finish Shall Be Nickel-Chrome Plated For Corrosion Resistance.Preferably Tapariya Or Eastman , Deep Socket Set Consist Of Sockets From 8 Mm To 22 Mm, Made Of Chrome Vanadium Steel, Fully Hardened, Tempered, And Chrome-Plated, The Sockets Shall Have Six-Point Or Twelve-Point Configurations For High Torque Applications, Suitable For Use With Ratchet Handles And Extension Bars.Preferably Tapariya Or Eastman , Combination Plier 6 Manufactured From High-Grade Alloy Steel, With Precision Machined Jaws, Cutting Edges Induction-Hardened For Long Life. Handles Shall Be Double-Dipped With Insulated Grips For Comfort And Safety.Preferably Tapariya Or Eastman , Combination Plier 8 Manufactured From High-Grade Alloy Steel, With Precision Machined Jaws, Cutting Edges Induction-Hardened For Long Life. Handles Shall Be Double-Dipped With Insulated Grips For Comfort And Safety.Preferably Tapariya Or Eastman , Circlip Plier Internal 7 Made Of High-Grade Alloy Steel, With Spring-Loaded Return And Polished Tips For Easy Installation And Removal Of Internal Retaining Rings, Handle Grips Shall Be Pvc Or Rubber-Coated.Preferably Tapariya Or Eastman , Circlip Plier External 7 Made Of High-Grade Alloy Steel, With Spring-Loaded Return And Polished Tips For Easy Installation And Removal Of Internal Retaining Rings, Handle Grips Shall Be Pvc Or Rubber-Coated.Preferably Tapariya Or Eastman , Locking Plier (Vice Grip Type) 10 With Drop-Forged Steel Jaws With Heat-Treated Teeth For Firm Gripping, Include An Adjustable Screw And Quick-Release Lever, Nickel-Plated Surface For Corrosion Protection.Preferably Tapariya Or Eastman , Diagonal Cutting Pliers, 6, Made Of Forged Alloy Steel, With Induction-Hardened Cutting Edges And Insulated Handles Suitable For Cutting Wires And Small Metal Parts.Preferably Tapariya Or Eastman , Long Nose Plier 6 Made Of Forged Alloy Steel With Slim Tapered Jaws For Precision Gripping And Cutting In Confined Spaces, 6 Overall Length, With Insulated Handles.Preferably Tapariya Or Eastman , Long Nose Plier 8 Made Of Forged Alloy Steel With Slim Tapered Jaws For Precision Gripping And Cutting In Confined Spaces, 8 Overall Length, With Insulated Handles.Preferably Tapariya Or Eastman , Adjustable Pipe Wrench Suitable For Gripping Pipes Up To 40 Mm Diameter Made Of Cast Iron Body With Drop-Forged Steel Jaws, Serrated And Induction-Hardened And Handle Painted Or Powder-Coated.Preferably Tapariya Or Eastman , Adjustable Pipe Wrench Suitable For Gripping Pipes Up To 75 Mm Diameter Made Of Cast Iron Body With Drop-Forged Steel Jaws, Serrated And Induction-Hardened And Handle Painted Or Powder-Coated.Preferably Tapariya Or Eastman , Heavy-Duty Pipe Wrench With Jaw Opening Up To 110 Mm Made Of Forged Alloy Steel, Precision-Machined Teeth For Firm Grip, Designed For Mechanical And Plumbing Use.Preferably Tapariya Or Eastman , Heavy-Duty Filter Wrench With High-Tensile Rubber Or Nylon Strap And Steel Handle For Removing Large Oil/Fuel Filters, Handle Length: Minimum 300 Mm. Suitable For Heavy Machinery Maintenance.Preferably Tapariya Or Eastman , Medium-Duty Filter Wrench With Adjustable Steel Band And Handle, Suitable For Medium-Sized Oil Filters. Chrome-Plated Finish With Non-Slip Grip.Preferably Tapariya Or Eastman , Ball Pein Hammer With 300 Gm Forged Steel Head, Hardened And Tempered. Fitted With A Strong Fiberglass Handle Suitable For Riveting, Striking, And Metal Forming.Preferably Tapariya Or Eastman , Soft Face Hammer With Dual Rubber Striking Faces To Prevent Surface Damage. Head Weight Approx. 300-500 Gm, Handle Made Of Fiberglass Preferably Tapariya Or Eastman , Non-Marring Mallet Hammer With Rubber Or Plastic Head 40 Mm And Sturdy Handle. Head Weight Approx. 1 Kg. Suitable For Precision Fitting Without Metal Deformation.Preferably Tapariya Or Eastman , Sledge Hammer With 500 Gm (2 Lb) Drop-Forged Steel Head, Hardened And Tempered. Handle Of Strong Wooden Or Fiberglass Construction, Securely Fixed To Head.Preferably Tapariya Or Eastman , Cold Chisels Made Of Chrome Vanadium Or Carbon Steel (18 Mm Dia Approax) , Hardened And Tempered To 58-60 Hrc. Size 25 Mm, Length 300 Mm, Approax Weight 500 Gm Ground Cutting Edge With Anti-Slip Striking End.Preferably Tapariya Or Eastman , Steel Wedges, Hardened And Ground, Used For Splitting Or Aligning. Made Of Forged Alloy Steel With A Rust-Resistant Finish 230 Mm Length 1.5 Kg.Preferably Tapariya Or Eastman , Adjustable Torque Wrench With Working Range 25-135 Nm. Drive Size 3/8 Or 1/2, Accuracy ±4% Of Indicated Value With Reversible Ratchet And Quick-Release Mechanism.Preferably Tapariya Or Eastman , Heavy-Duty Adjustable Torque Wrench, Range 70-340 Nm. 1/2 Drive, Accuracy ±4%, Chrome Vanadium Construction With Calibration Certificate.Preferably Tapariya Or Eastman , High-Capacity Torque Wrench, Range 135-540 Nm. 3/4 Drive, Accuracy ±4%, Knurled Handle For Non-Slip Grip, Supplied With Protective Case And Calibration Certificate.Preferably Tapariya Or Eastman , Part 2- Description ( Measuring Tools ) , Steel Scale Set (5 Nos) Made Of High-Quality Tempered Stainless Steel With Etched And Permanently Engraved Graduations In Both Metric (Mm/Cm) And Inch Units. Straight, With Accurately Ground Edges And Smooth Surfaces, Graduation Accuracy Shall Conform To Is 1481:1970 Or Equivalent. Lengths : 150 Mm, 300 Mm, 600 Mm, 450 Mm, 1000 Mm. Each Scale Shall Have Clear Visibility Markings And Corrosion-Resistant Satin Chrome Finish.Preferably Mitutoyo Or Bosch , Vernier Calipers Made Of Stainless Steel, Precision-Ground And Finished, With A Measuring Range Of 0-200 Mm And Least Count 0.02 Mm / 0.001 Inch Capable Of Internal, External, Depth, And Step Measurements. Vernier Scale And Main Scale Markings Shall Be Clearly Etched For Long-Term Readability. The Instrument Shall Conform To Is 3651:1981 Or Din 862 Standards. A Locking Screw Shall Be Provided For Measurement Retention, And The Tool Shall Be Supplied In A Protective Case.Preferably Mitutoyo Or Bosch , Outside Micrometer (0-25 Mm Range) Of Mechanical Analog Type, Conforming To Is 2967:1975 Or Din 863 Standards. The Frame Shall Be Rigid And Heat-Insulated, With Carbide-Tipped Measuring Faces, A Friction Thimble, And A Ratchet Stop For Consistent Measuring Pressure. The Least Count Shall Be 0.01 Mm, And The Thimble And Sleeve Shall Have Clearly Graduated Markings. The Micrometer Shall Be Supplied With A Setting Standard And Calibration Certificate.Preferably Mitutoyo Or Bosch , Outside Micrometer (25-50 Mm Range) Of Mechanical Analog Type, Conforming To Is 2967:1975 Or Din 863 Standards. The Frame Shall Be Rigid And Heat-Insulated, With Carbide-Tipped Measuring Faces, A Friction Thimble, And A Ratchet Stop For Consistent Measuring Pressure. The Least Count Shall Be 0.01 Mm, And The Thimble And Sleeve Shall Have Clearly Graduated Markings. The Micrometer Shall Be Supplied With A Setting Standard And Calibration Certificate.Preferably Mitutoyo Or Bosch , Feeler Gauges Made Of Hardened And Tempered Spring Steel, Precision-Ground To Required Thickness, And Permanently Marked With Size Values. The Set Shall Include Multiple 75 Mm Long Blades Of 30 Different Thicknesses 0.03 Mm To 1.00 Mm Assembled In A Steel Holder With Pivot. Each Blade Shall Be Rust-Resistant And Polished For Smooth Operation. The Gauge Shall Conform To Is 3179:1982 Or Equivalent Standards.Preferably Mitutoyo Or Bosch , Wire Gauge (Standard Bs 1505 Type) Manufactured From Hardened And Tempered Steel With Precisely Cut Slots For Wire Sizes 1 To 36 Swg. The Gauge Shall Be Circular Or Rectangular In Shape With Permanent Engraved Markings. The Tool Shall Comply With Bs 3737 / Is 3177 Standards For Accuracy. Surface Shall Be Satin Chrome Or Nickel Plated To Resist Corrosion Suitable For Measuring Diameters Of Wires, Rods, And Drill Bits.Preferably Mitutoyo Or Bosch , Inside Calipers Shall Be Made Of Forged Steel Or Stainless Steel, Polished And Hardened. The Legs Shall Have Finely Ground Points With A Pivot Joint And Tension Adjustment For Smooth Movement. Measuring Range: 20-170 Mm Suitable For Measuring Internal Dimensions And Bore Diameters. Shall Conform To Is 3564:1985 Standards.Preferably Mitutoyo Or Bosch , Outside Calipers Made Of High-Grade Carbon Or Stainless Steel With Hardened Tips, Spring Joint, And Knurled Adjustment Nut For Precision. Shall Conform To Is 3564:1985 Or Equivalent Standards. Surface Finish: Polished Or Chrome-Plated. 12 Inch Size Preferably Mitutoyo Or Bosch , Centre Punch Manufactured As Per Is 7177 - 1999 Or Equivalent, Made Of High Carbon Or Alloy Tool Steel, Hardened And Tempered At The Striking End And Point. Length: Approximately 150 Mm, Approximate Weight 160 Gm With Point Angle Of 60° ± 2°. The Striking End Shall Be Chamfered To Prevent Mushrooming. Surface Finish Shall Be Black Oxide Or Polished. Suitable For Marking Centers On Metal Surfaces Before Drilling Operations.Preferably Mitutoyo Or Bosch , Portable Digital Non-Contact Tachometer Of Reputed Make, With A Non-Contact Measuring Range Of Approximately 10 To 99,999 Rpm And Accuracy Not Inferior To ±0.04% ±2 Digits. Equipped With A Digital Lcd Display, Data Hold, Counting Function, And Computer/Usb Interface For Data Transfer, A Working Distance Of Around 0.2 M With A ±30° Working Angle, Reflective Tape, Interface Cable, And Carrying Case. Conforming To Iec 61010-1 / Is 13875.Preferably Mitutoyo Or Bosch , Part 3- Description ( Auto Electrical And Pump) , Portable True-Rms Digital Multimeter Of High-Accuracy, Capable Of Measuring Ac/Dc Voltage Up To 1000 V, Ac/Dc Current Up To 10 A, Resistance, Capacitance, Frequency, Diode, And Continuity. The Meter Should Have Features Like Auto-Ranging, Data-Hold, Min/Max, And Relative Measurement Functions With A Large Back-Lit Display Of Minimum 4000 Counts Or Higher. The Instrument Shall Have Overload Protection, Fused Input Terminals, And Comply With Safety Category Cat Iii 1000 V Or Cat Iv 600 V As Per Iec 61010-1. The Unit Shall Be Housed In A Protective Insulated Casing Suitable For Field Use And Supplied Complete With Test Leads, Batteries, Protective Case, And Calibration Certificate.Preferably Continental Or Bosch , Handheld Clamp Meter (True-Rms Type) Designed For Measurement Of Ac And Dc Currents Up To 1000 A, With Additional Functions For Ac/Dc Voltage, Resistance, Frequency, And Continuity. The Jaw Opening Shall Accommodate Conductors Up To 40-60 Mm In Diameter. The Meter Shall Feature A Large Digital Display, Auto-Range Selection, Data-Hold And Peak Capture Functions, And Have An Accuracy Of ±2 % Or Better. It Shall Meet Cat Iii 1000 V / Cat Iv 600 V Safety Standards, Include Overload And Transient Protection, And Be Built In A Shock-Resistant Insulated Body. The Clamp Meter Shall Be Supplied With Test Leads, Carrying Pouch, And Calibration Certificate.Preferably Continental Or Bosch , Wire Strippers Suitable For Removing Insulation From Copper Conductors Ranging From 0.5 Mm² To 6 Mm² Preferably Continental Or Bosch , Ratchet-Type Crimping Tool Designed For Insulated And Non-Insulated Terminals 1.5 Mm² To 10 Mm², With Interchangeable Dies And Ergonomic Handles.Alloy Steel Duly Hardened & Tempered Preferably Continental Or Bosch , Heavy-Duty Mechanical Or Ratchet Type Cable Cutters Suitable For Cutting Copper And Aluminium Cables Up To 300 Mm² Preferably Continental Or Bosch , Soldering Iron Shall Be Of 40 W Capacity Insulated Handle. Cable Lugs And Ferrules Shall Be Of Tinned Copper, Crimp Type, Conforming To Din 46234/46235 Standards Preferably Continental Or Bosch , Infrared Thermometer (Ir Gun) Shall Measure From -50 °C To +550 °C With Laser Targeting And Digital Display. Should Have Rugged, Insulated Housings And Be Supplied With Charger, Carry Case, And Calibration Certificate.Preferably Continental Or Bosch , Battery Load Tester (12V) Shall Provide Controlled Load Up To 2-200 Ah To Assess Battery Condition By Measuring Voltage Drop And Internal Resistance Instruments Shall Have Clear Displays, Polarity Protection, Insulated Clamps, And Rugged Enclosures For Workshop Use.Preferably Continental Or Bosch , Smart Battery Charger Shall Provide Automatic Multi-Stage Charging For 12 V Batteries With Protections For Overcharge And Polarity Reversal.Preferably Continental Or Bosch , Part 4- Description ( Tractor & Auto Mobile) , Spring Compressor - Head Valve Type, Of Reputed Make Made Of High-Strength Carbon Steel With A Corrosion-Resistant Finish, Having An Overall Length Of Approximately 750 Mm And Weight Around 700 G Conforming To Relevant Standards For Hand Tools Such As Is 5781 / Is 6131 / Iso 6787 Or Equivalent. Preferably Tapariya Or Bosch , Piston Ring Compressor (Set Of 3) Of Reputed Make, Made Of Hardened And Tempered Alloy Or Carbon Steel With A Polished Or Chrome-Plated Corrosion-Resistant Finish, And Provided With A Ratchet Or Key-Type Locking Mechanism For Uniform Compression And Easy Releasewith An Adjustable Diameter Range Suitable For Standard Engine Pistons (50 Mm To 125 Mm With 75 Mm Height, 90 Mm To 175 Mm With 100 Mm Height, And 90 Mm To 175 Mm With 150 Mm Height), Conforming To Relevant Standards Such As Is 7347 / Iso 1174 To Be Supplied Complete With Necessary Tightening Wrench Or Handle.Preferably Tapariya Or Bosch , Portable Diesel Injector Nozzle Pop Tester, With A Dual-Scale Pressure Gauge (0-400 Bar / 0-6000 Psi), A Manual Hydraulic System With An Oil Cup Capacity Of 0.8 Litres, Constructed From High-Grade Plastic, And A Rugged Metallic Pump Body, Approximate Weight Of 4.25 Kg, Conforms To Iso 4113 (Calibration Fluid For Diesel Injection Equipment) And Iso 4008-1 / Iso 4008-2 (Diesel Fuel Injection Test Equipment - Testing Of Injection Pumps And Injectors).Preferably Tapariya Or Bosch , Injector Puller Set (8 Pcs), Including Eight Precision-Engineered Oxidized Carbon Steel Components Comprising An Inertia Hammer, A Joint For Accessing Hard-To-Reach Areas, And Six Threaded Adapters With Sizes M12×1.75, M17×1, And M27×1, Ensuring Compatibility With Injectors From Major Manufacturers, Hammer Length Of 350 Mm All Conforms To Iso 6789:2017 (Torque Tools - Requirements And Test Methods) And Din 3122 (Hand-Operated Tools For Mechanical Drive). , Mechanical Puller (3?, 2/3-Jaw, Double Ended) Of Reputed Make Made Of Hardened And Tempered Alloy Or Carbon Steel And Finished With Corrosion-Resistant Coating, With Interchangeable 2-Jaw And 3-Jaw Configuration, Allowing Both Internal And External Gripping Applications, Nominal Jaw Size Shall Be 3 Inch (76.2 Mm), With A Spread Of Approximately 76 Mm, Reach Of About 65 Mm, And Working Diameter Range From 15 Mm To 80 Mm, Threaded Spindle Length 125 Mm, Conforming To Is 6149 / Iso 2985 Standards. Preferably Tapariya Or Bosch , Mechanical Puller (8?, 2/3-Jaw, Double Ended) Of Reputed Make Made Of Hardened And Tempered Alloy Or Carbon Steel And Finished With Corrosion-Resistant Coating, With Interchangeable 2-Jaw And 3-Jaw Configuration, Allowing Both Internal And External Gripping Applications, Nominal Jaw Size Shall Be 8 Inch (203.2 Mm), With A Spread Of Approximately 203 Mm, Reach Of About 177 Mm, And Working Diameter Range From 30 Mm To 210 Mm, Threaded Spindle Length 174 Mm, Conforming To Is 6149 / Iso 2985 Standards.Preferably Tapariya Or Bosch , Valve Seat & Face Cutter Set Of Seat Cutters, Face Cutters, Arbors, And Pilots (20 Nos) Of High-Grade Alloy Steel With Precision-Ground Cutting Edges, Hardened And Tempered To Maintain Cutting Efficiency, Conforms To Is 5517:1993 (Specification For Cutting Tools - General Requirements) And Iso 513 (Classification And Application Of Cutting Tool Materials) Preferably Tapariya Or Bosch , T-Handle Spark Plug Socket Wrench (21 Mm) Carbon Steel With A Chrome-Plated Finish, With A 360-Degree Swivel Head For Flexible Operation, A Plastic Grip On The T-Handle, A Rubber Insert Within The Socket, An Approximate Weight Of 110 Grams, And Conforming To Relevant Standards For Hand Tools. Preferably Tapariya Or Bosch , 10Pcs Carburetor Adjusting Tool Kit Including: 21-Teeth Splined, 7-Teeth Splined, Single D, Small Head Single D, Double D, Pac Man, Small Head Pac Ma,N Hexagon Shaped, Six Star, And Carburetor Cleaning Tools All Made Of High-Quality Stainless Steel Wear Resistant And Long Lasting With Ergonomic Handle Comfortable To Grip And Stable To Use.Preferably Tapariya Or Bosch , The Heavy-Duty Spark Plug Cleaner And Tester Designed To Clean And Test Spark Plugs Under Simulated Engine Conditions, Operates On A 220 V Ac Supply And Incorporates A 12 V / 12 Kv Ignition Coil For Spark Generation And A 220 V / 12 V Electronic Vibrator For Cleaning Including A Pressurized Testing Chamber With A Working Pressure Of Up To 12 Kgf/Cm² And A Separate Abrasive Cleaning Chamber Equipped With A Double-Acting Valve For Blasting And Dust Removal, Should Be Compatible With Spark Plug Sizes M10, M12, M14, And M18 Through Interchangeable Rubber Adapters And Features A Pressure Regulator For Maintaining Safe And Consistent Operation. Product Should Conform To General Standards For Electrical Safety And Workshop Equipment, Such As Is 302 (Part 1): Safety Of Electrical Equipment, Is 10326: Automotive Service Equipment - Spark Plug Testers, Or Equivalent International Standards Preferably Tapariya Or Bosch , Portable Fuel And Vacuum Gauge Tester Kit For Testing Fuel Pump Pressure, Fuel Pump Vacuum, Carburettor Intake, And Manifold Vacuum Systems In Petrol Engines With Dual Gauges - A Pressure Gauge Ranging From 0 To 10 Psi (0-0.7 Kg/Cm²) And A Vacuum Gauge Ranging From 0 To 28 In-Hg (0-70 Cm-Hg) - For Accurate Measurement Of Engine Fuel And Air System Performance, With Standard Automotive Fittings For Quick Connection To Various Fuel And Vacuum Lines And Conforming To Is 1446: Automotive Test Equipment - Pressure And Vacuum Gauges Or Equivalent International Standards Like Sae J1812 For Fuel System Testing Instruments.Preferably Tapariya Or Bosch , Petrol Engine Compression Tester Kit (400 Mm) Including Threaded Adaptors In Sizes M10, M12, M14, And M18, Along With Two Rubber Cone Ends For Both Threaded And Non-Threaded Testing, Equipped With Straight And Angled Push-On Connectors And A 400 Mm Flexible Hose, To Diagnose Issues Related To Piston Rings, Valves, Or Head Gaskets, Suitable For Cars, Motorcycles, And Small Petrol Engines.Preferably Tapariya Or Bosch , Heavy-Duty Sprocket Chain Breaker And Splitter Tool Suitable For Breaking, Splitting, And Repairing Chains Of Size 420 To 530 Made Of High-Grade Carbon Steel Preferably Tapariya Or Bosch , Compact Chain Saw Grinder For Precise Grinding Of Chain Saw Blades For A Rated Voltage Of 220-230 V At 50/60 Hz, With An Input Power Of 300 W And A No-Load Speed Of 8400 Rpm, Equipped With A 100 Mm Grinding Wheel Suitable For Most Standard Chain Saw Chains, Weighing Around 2.5 Kg, Conforming To General Safety And Performance Standards Such As Is 302 (Part 2/Sec 201): Electrical Safety For Hand-Held Tools And Iec 60745-2-4 Preferably Tapariya Or Bosch , Soldering Station Operating On A 220-240 V Ac, 50/60 Hz Supply, Input Power Of 60 W, With A Preheat Time Of Approximately 1 Minute, Digital Temperature Display, Adjustable And Thermostatic Temperature Control Via A Rotary Knob, Built-In Ceramic Heating Element, A Straight Tip Head, A Durable Stand For Iron Placement, Packed In A Color Box, Conforms To Iec 60335-2-45: Household And Similar Electrical Appliances - Safety Of Portable Heating Tools And Iec 61340-5-1: Protection Of Electronic Devices .Preferably Tapariya Or Bosch , Compact, Durable, And Easy To Operate Portable High-Pressure Hand-Operated Portable Grease Pump With A 10 Kg Grease Capacity And Delivers A Material Output Of Approximately 3 Grams Per Stroke, Maximum Block Pressure Of 140 Kg/Cm², A 2-Meter High-Pressure Rubber Hose Fitted With End Connections.Preferably Tapariya Or Bosch , Double Piston Lever Grease Gun Delivering Up To 2.4 Grams Of Grease Per Stroke, Pressures Up To 6000 Psi, With A Double-Piston Mechanism, Compact And Lightweight (Approx. 2 Kg).Preferably Tapariya Or Bosch , Durable And Easy-To-Use Steel Lubrication Oil Dispenser Can For Smooth And Controlled Lubrication With A 500 Ml Capacity, Made From High-Quality Steel With A Powder-Coated Finish, The Can Is Lightweight (Approx. 200 G), Waterproof, And Ergonomically Designed For Comfortable Handling And Precise Oil Flow. Preferably Tapariya Or Bosch , Part 5- Power Tools & Equipments , Corded Type Electric Impact Wrench Conforming To Is 7151:1983 / Iec 60745-2-2 [Vibration (=11.5 M/S²), And Noise (104 Db(A))], With A Continuous Input Rating Of 400 W,. It Shall Provide A Maximum Fastening Torque Of 350 N·M, With A No-Load Speed Of 2000 Rpm And Impact Rate Of 2000 Blows Per Minute, 12.7 Mm (½) Square Drive, A 2.5 M Power Supply Cord. The Housing In Impact-Resistant Polymer With Reinforced Internal Metal Gear Casing, Suitable For Tightening And Loosening Ensuring Efficient Operation For Both Standard (M12-M22) And High-Strength Bolts (M12-M16) In Vehicle And Machinery Maintenance Applications Preferably Makita Or Bosch , Heavy-Duty Angle Grinder, Of Reputed Make, Single Phase 220-240 V, 50/60 Hz Ac Supply, Input Power 2200 W No-Load Speed 8500 Rpm To Use With 180 Mm (7) Diameter Abrasive Wheels, And Equipped With Side Handle, Wheel Guard, And Spindle Lock A 2.0 M Power Supply Cord And Conforming To Is 7554 / Iec 60745-2-3 / Iso 11148-7 Or Equivalent Standards (Low Vibration Level (=6.5 M/S²), Sound Pressure Level Not Exceeding 91 Db(A)). Preferably Makita Or Bosch , Electric Power Drill (Corded Type) Of Reputed Make, Single Phase 220-240 V, 50 Hz Ac Supply, 350 W And Variable Speed Range Up To 3000 Rpm (No Load). Including A Pistol-Grip Body, Keyed Or Keyless Chuck, And A 2.0 M Power Supply Cord Complying With Is 7554 / Iec 60745 / Iso 11148 Or Equivalent Standards, [Low Vibration (=3.0 M/S²) And Sound Pressure Level Below 80 Db(A)] Supplied Complete With Chuck Key, Side Handle (If Applicable), And Instruction Manual.Preferably Makita Or Bosch , Portable Electric Heat Gun Powered By An 1800 W Motor Operating At 230 V Ac, For Adjustable Airflow Between 350-550 L/Min And A Working Temperature Range Of 60°C To 550°C, Selectable In Three Stages (60/350/550°C), Achieves Full Heat-Up Within 1 Minute, With A Heat-Resistant Plastic Body And Heat Isolation Cap, Weighs 750 G And Features A 2 M Cord Length And Conforming To Iec 60335-2-45: Household And Similar Electrical Appliances - Safety Of Portable Heating Tools And Iec 61000-3-11/12: Electromagnetic Compatibility Standards. Preferably Makita Or Bosch , Portable Air Compressor, Of Reputed Make, Single Phase 230 V, 50 Hz Ac Supply, Fitted With An Electric Motor Of 2.0 Hp (1.5 Kw) A Maximum Working Pressure Of 8 Bar, Free Air Delivery Not Less Than 200 Lpm (7.2 Cfm), And A Motor Speed Of 2850 Rpm. Air Receiver Tank Of 50 Liters Capacity, Conforming To Is 5456 / Is 2825 Standards And The Compressor Shall Conform To Is 10437 / Iso 1217, And Fitted With Pressure Gauge, Safety Valve, Drain Valve, And Automatic Pressure Switch. The Complete Unit Shall Be Portable, Vibration-Damped, And Equipped With Wheels And Handle For Easy Movement. Preferably Makita Or Bosch , Single Phase Annual Rate Contract Welding Machine Of Reputed Make, With Inverter-Based Igbt Technology To Be Operated On Ac 220V ±15%, 50/60 Hz Single Phase Supply And Deliver A Welding Output Current Up To 400 Annual Periodical Maintenance With A Duty Cycle Of Not Less Than 60%, An Efficiency Of Minimum 80% And Power Factor Not Less Than 0.73, With Insulation Class F And Protection Grade Ip21 As Per Is 2879 / Is 3024 Or Equivalent International Standards. And Necessary Accessories Such As Welding Cable, Electrode Holder, And Earth Clamp Etc. Should Be Included.Preferably Makita Or Bosch , Bench Grinder, Of Reputed Make, Single Phase 220-240 V, 50 Hz Ac Supply Equipped With A 350 W Induction Motor Of 2950 Rpm. Two 200 Mm Diameter Grinding Wheels Each Provided With Eye Shields And Wheel Guards, Heavy-Duty Aluminum Base With Tool Rest, Tool Storage Box, And Safety Accessories Etc. Complete Conforming To Is 302 / Is 6932 / Iec 61029 Or Equivalent.Preferably Makita Or Bosch , Bench Drill Press, Of Reputed Make, Single Phase 120 V Ac, 50/60 Hz Fitted With Electric Motor Of Approximately 1/3 Hp Rating, Manually Adjustable Work Table With Depth Stop For Accurate Drilling. Chuck Guard, Power Switch With Overload Protection, And Belt Or Gear-Driven Spindle System Conforming To Applicable Safety And Performance Standards Such As Is 2425 / Iso 16089 / Iec 61029 Or Equivalent Supplied Complete With Drill Chuck, Key, And Instruction Manual.Preferably Makita Or Bosch , Part -6 Furniture And General , Bench Vice Of Heavy-Duty Engineers Type, Suitable For Fitting And General Workshop Applications With Jaw Width 125 Mm (5 Inches), With Replaceable Serrated Hardened Steel Jaws For A Firm Grip On Workpieces, The Body And Sliding Jaw Shall Be Made From High-Grade Cast Iron Or Forged Steel, Precision Machined To Ensure Smooth Operation And Alignment. The Vice Shall Be Equipped With A Large-Diameter Acme-Threaded Spindle And Steel Handle With Knurled Ends For Easy Tightening (1600 Kg Tightening Force) And Release. The Vice Includes A 360° Swivel Base With Locking Mechanism, Allowing Positioning And Adjustment As Required During Work. The Anvil Surface On The Rear Shall Be Machined And Hardened, Suitable For Light Hammering Operations. The Vice Shall Have A Clamping Capacity Of At Least 150 Mm, And All Moving Parts Shall Be Protected Against Rust And Corrosion By Paint Or Plating. The Bench Vice Should Be Suitable For Mounting On Heavy-Duty Wooden Or Steel Workbenches And Capable Of Withstanding Heavy Mechanical Use In Workshops And Maintenance Facilities. It Shall Conform To Is: 2586 (Specification For Bench Vices, Heavy Duty) Or Equivalent Standard.Preferably Goderej Or Dewalt , Heavy-Duty Roller Tool Cabinet With 4 Drawers And One Cupboard Suitable For Use In Mechanical, Workshops For Organized Storage Of Hand Tools, Instruments, And Accessories Made Of High-Quality Cold-Rolled Steel Sheet With A Cabinet Body Thickness Of 0.8-1.0 Mm And Drawer Sheet Thickness Of 0.7 Mm, With An Overall Size Of 765 Mm (L) × 465 Mm (W) × 812 Mm (H) And An Overall Height Of 976 Mm Including Casters. Drawers Of Size 536 Mm (L) × 410 Mm (W) × 74.5 Mm (H), Mounted On Precision Ball-Bearing Slides And The Top Panel Area Should Be Suitable For Tool Placement During Maintenance Work. The Unit Should Be Mounted On Four Heavy-Duty Casters Of Size 5? × 2?, Two Of Which Shall Be Swivel Casters With Locking Brakes For Easy Mobility And Stability During Use. The Cabinet Shall Include A Central Locking System For All Drawers, Should Be Surface-Treated With Powder Coating For Corrosion Resistance And A Smooth Finish. The Tool Cabinet Shall Conform, Where Applicable, To The General Guidelines Of Is 7155 (Industrial Trolleys And Cabinets) And Iso 9001:2015 Quality Manufacturing Standards. Preferably Goderej Or Dewalt , Oil Drain Pan Made Of High-Density Polyethylene (Hdpe) With A Capacity Of 16 Litres Including Integrated Handles, A Pouring Spout, And Anti-Spill Lips To Prevent Leakage During Draining Suitable For Chemical Resistance To Engine Oil, Transmission Fluids, And Coolants.Preferably Goderej Or Dewalt , Oil Drain Pan Made Of High-Density Polyethylene (Hdpe) With A Capacity Of 8 Litres Including Integrated Handles, A Pouring Spout, And Anti-Spill Lips To Prevent Leakage During Draining Suitable For Chemical Resistance To Engine Oil, Transmission Fluids, And Coolants.Preferably Goderej Or Dewalt , Rack For Batteries, Made Of Well-Seasoned Hardwood Or Marine Plywood With Sturdy Ms Frame Or Wooden Supports. Includes 3-4 Ventilated Shelves With Acid-Resistant Coating And Removable Rubber Or Pvc Mat. Designed To Hold Multiple Batteries Safely And Prevent Corrosion. Approx. Size: 1500 Mm × 1000 Mm × 450 Mm.Preferably Goderej Or Dewalt , Rack For Lubricants Constructed From Treated Wood Or Plywood Frame With Raised-Edge Shelves To Contain Spills. Each Shelf Shall Carry At Least 100 Kg And Be Coated With Oil-Resistant Paint. Suitable For 1-20 L Containers. Approx. Size: 1800 Mm × 1200 Mm × 450 Mm.Preferably Goderej Or Dewalt , Rack For Spares Fabricated From High-Quality Wood Or Plywood With Ms Reinforcement. Includes Adjustable Or Fixed Shelves (3-5 Tiers), Each Supporting Up To 150 Kg (Udl). Finished With Protective Paint Or Polish For Workshop Use. Approx. Size: 2000 Mm × 900 Mm × 450 Mm.Preferably Goderej Or Dewalt , Industrial Wet And Dry Type Vacuum Cleaner With A Power Rating Of 1500 W And Operating Voltage Of 220-240 V, 50 Hz, Suitable For Workshop And Service Bay Cleaning Applications With A Capacity Of 35 Litres, A Vacuum Suction Pressure Of 200 Mbar And An Airflow Rate Of 53 L/S, Ensuring High-Efficiency Dust And Liquid Removal. The Tank Should Be Made Of Corrosion-Resistant Stainless Steel (Minimum Ss 304 Grade) With Heavy-Duty Caster Wheels For Mobility. It Should Be Provided With A Flexible 5 M Power Cable, Washable Filters, Blower Function, And Accessories For Both Wet And Dry Operation. The Vacuum Cleaner Shall Conform To Iec 60335-2-69 (Safety For Wet And Dry Vacuum Cleaners For Commercial Use) Or Equivalent Indian Standard Is 11621:1986, And Include Overload And Thermal Protection Features For Motor Safety.Preferably Goderej Or Dewalt , Portable, Electric-Operated Industrial Pressure Washer Conforming To Iec 60335-2-79 / Is 8442 With A Power Rating Of 1700 W (230 V, 50 Hz Single-Phase Supply) And A Maximum Working Pressure Of 130 Bar And A Flow Rate Of 7 Litres Per Minute, With Self-Priming Capability Of 0.5 M, High-Pressure Foam Detergent System, 6 M Pvc Hose, Manual Hose Reel, 5 M Power Cable, 3-In-1 Nozzle And Ergonomic Handle Preferably Goderej Or Dewalt , Part 7-Safety Tools , Abc Powder Type Fire Extinguishers, Is 15683:2018 Compliant, Portable Type With A Minimum Capacity Of 4 Kg Suitable For Class A Fires. Dry Chemical Powder (Mono Ammonium Phosphate) Based, Stored Pressure Type With Working Pressure Of 15 Bar, Suitable For Electrical And Combustible Material Fires.Extinguisher Should Have Isi Certification, Pressure Gauge, Discharge Nozzle, Wall Mounting Brackets, And Color Coding As Per Is 2190. They Shall Be Factory-Filled, Tested At Twice Working Pressure, And Supplied With Inspection Tag And Instruction Label.Preferably Honeywell Or Karam , Co2 Type Fire Extinguishers, Is 15683:2018 Compliant, Portable Type With A Minimum Capacity Of 4.5 Kg Suitable For Class B Fires . Carbon Dioxide Gas Type With Seamless High-Pressure Steel Cylinder Conforming To Is 7285, Discharge Hose With Horn, And Designed For Electrical And Flammable Liquid Fires. Extinguisher Sould Have Isi Certification, Pressure Gauge, Discharge Nozzle, Wall Mounting Brackets, And Color Coding As Per Is 2190. They Shall Be Factory-Filled, Tested At Twice Working Pressure, And Supplied With Inspection Tag And Instruction Label.Preferably Honeywell Or Karam , Foam Type Fire Extinguishers, Is 15683:2018 Compliant, Portable Type With A Minimum Capacity Of 9 L, Suitable For Class C Fires. Stored Pressure Or Cartridge Type Using Aqueous Film-Forming Foam Suitable For Flammable Liquid Fires. Extinguisher Should Have Isi Certification, Pressure Gauge, Discharge Nozzle, Wall Mounting Brackets, And Color Coding As Per Is 2190. They Shall Be Factory-Filled, Tested At Twice Working Pressure, And Supplied With Inspection Tag And Instruction Label.Preferably Honeywell Or Karam , Fire Blanket Shall Be Made Of 840 Gsm Glass Fiber Or Kevlar-Coated Woven Fabric, Resistant To Temperatures Up To 550°C, Conforming To Is 11871 / Bs En 1869, And Provided In A Quick-Release Wall-Mount Case. Standard Blanket Size: 2.00 M × 1.00 M For Personnel Protection And Small Fire Suppression.Preferably Honeywell Or Karam , First Aid Box Of Size 32.5(H) X 28.5(W) X 8(D) Cmshall Conform To Is 13154 (Part 1-3), Made Of Powder-Coated Metal, Gi Or Abs Plastic, Waterproof And Corrosion Resistant, To Keep All Essential Medical Supplies For Industrial Workshops (Bandages, Antiseptics, Gauze, Adhesive Strips, Scissors, Burn Cream, Splints, Sterile Pads, And Cpr Mask).Preferably Honeywell Or Karam , Eye Wash Station Wall Mount Type, Made Of Stainless Steel Push Plate 12.7 Mm (1/2 Inch Bsp) Inlet, 4810 Ss, Providing Continuous Flow At 1.5 L/Min Per Outlet, Operated By A Push Plate, Complying With Ansi Z358.1 / Is 10592.Preferably Honeywell Or Karam , Emergency Safety Shower Shall Deliver A Minimum Of 75 L/Min At Operating Pressure Of 2-6 Bar, With Pull-Rod Activation And Stay-Open Valve Ss Stay Open Ball Valve With Push Plate, Material Of Construction Gi And Abs Plastic. Preferably Honeywell Or Karam , Foldable Stretcher Shall Be Lightweight Aluminum Or High-Tensile Steel Frame With Washable Canvas Sheet, Capable Of Carrying 120 Kg Load, Fitted With Safety Straps And Rubber Handles, Conforming To Is 1904 / En 1865.Preferably Honeywell Or Karam , Ppe: Helmets Hdpe Or Abs Shell, Is 2925 Compliant, Chin Strap, Sweatband, Impact-Resistant Up To 50 Joules.Preferably Honeywell Or Karam , Ppe: Goggles Polycarbonate Lenses, Anti-Scratch And Uv-Resistant, Is 5983 / En 166 Compliant, Side Shields.Preferably Honeywell Or Karam , Ppe Industrial Gloves: For Mechanical Work-Leather Or Nitrile (Is 6994); For Chemical Work-Pvc/Neoprene (En 374); For Electrical Insulation-Rubber Class 0 (Is 4770).Preferably Honeywell Or Karam , Ppe: Safety Boots Confirming To Is 15298 / En 20345 Compliant, Steel/Composite Toe Cap (200 J Impact), Oil- And Slip-Resistant Sole, Steel Mid Sole Antistatic.Preferably Honeywell Or Karam , Ppe: Protective Overalls With 100% Cotton 210 Gsm Or Fire-Retardant Fabric, Full-Sleeve, High-Visibility Reflective Tapes Per Is 15748 / En 20471.Preferably Honeywell Or Karam , Electrical Insulated Gloves Conforming To Is 4770 / Iec 60903, Suitable For Class 0 (1000 V Ac / 1500 V Dc) Electrical Protection, Made Of High-Dielectric Natural Rubber, Seamless, And Rolled Cuff Type. Each Glove Shall Undergo Routine Dielectric Test At 5 Kv For 1 Minute With No Puncture Or Flashover. The Gloves Shall Be Category Rc (Resistant To Acid, Oil, Ozone, And Low Temperature) And Provided With A Cotton Inner Liner And Storage Pouch. Supplied With Test Certificate Indicating Batch Number, Test Voltage, And Date.Preferably Honeywell Or Karam , Welding Face Shield Suitable For Full-Face Protection During Welding, Grinding, And Metal Fabrication Works With A Shield Size Of Approximately 9 X 12, Made Of Durable Polypropylene Providing High Impact, Heat, And Corrosion Resistance. The Face Shield Shall Include An Adjustable Ratchet-Type Headgear With Multiple Adjustment Positions To Ensure A Secure And Comfortable Fit For Prolonged Use. The Approximate Weight Shall Be 1.5 Kg Or Less, And The Product Shall Be Supplied As One Complete Unit. The Face Shield Should Conform To General Industrial Safety Standards Suitable For Use In Workshops.Preferably Honeywell Or Karam , Industrial-Grade Welding Gloves Suitable For Providing Protection, Comfort, And Dexterity During Welding, Cutting, And Metal Fabrication Operations, Made From Premium Split Leather (Cowhide Or Goatskin) With A Minimum Thickness Of 1.2 Mm, Offering High Resistance To Heat, Sparks, And Mechanical Abrasion. The Inner Lining Shall Be Made Of Soft Flame-Retardant Cotton Or Fleece, Providing Insulation Against Heat And Comfort For Prolonged Use. Each Glove Shall Have Reinforced Palm And Finger Patches For Added Durability And Better Grip While Handling Tools And Hot Metal Objects. The Gloves Should Be Stitched With Heat-Resistant Thread To Prevent Seam Failure During Exposure To High Temperatures. The Length Shall Not Be Less Than 14 Inches (350 Mm), Ensuring Full Hand And Wrist Protection, With Extended Cuffs To Safeguard The Lower Forearm Against Welding Spatter And Radiant Heat. The Gloves Should Be Conformed To En 388 (Mechanical Risks) And En 407 (Thermal Hazards) Or Equivalent Indian Standards (Is 6153). They Shall Be Suitable For Mig, Tig, Arc, And Gas Welding Operations. Should Be Heat And Flame-Resistant, Puncture And Tear-Resistant, And Designed For Repeated Use In Demanding Industrial Environments. The Pair Shall Be Supplied In Standard Size (Large/Universal Fit) And Shall Bear Proper Labeling Indicating Brand, Size, And Conformity To Relevant Standards.Preferably Honeywell Or Karam , Part 8 -Lifting And Hoisting , Heavy-Duty, Low-Profile Type Hydraulic Trolley Jack Suitable For Lifting Vehicles Or Machinery Up To A Rated Capacity Of 3 Tons. The Jack Shall Be Constructed From High-Grade Steel With Welded Frame For Superior Strength And Stability, A Lifting Range From Approximately 130 Mm To 465 Mm, Operated Through A Hydraulic Lifting Mechanism Actuated By A Detachable Pump Handle. Should Be Equipped With A Safety Overload Valve To Prevent Lifting Beyond Rated Capacity, And Precision Hydraulic Seals To Prevent Oil Leakage. The Unit Shall Feature A 360° Swivel Rear Caster And Wide Front Wheels For Easy Maneuverability. The Saddle Shall Be Grooved Or Rubber-Coated For Secure Load Contact. The Jack Shall Conform To Is 7620 / Asme-Pase Or Equivalent Standards, And Shall Be Finished With Corrosion-Resistant Powder Coating. Supplied Complete With Hydraulic Oil Filled And Ready For Use.Preferably Ravaglioli Or Atselgi , Floor-Mounted Electro-Hydraulic Two Post Lift Of 4,000 Kg Capacity With Symmetric Lifting Arms (Front And Rear Adjustable) And Double Hydraulic Cylinders, Made Of High-Strength Steel Columns With A Minimum Inside Column Clearance Of Approximately 2799 Mm And A Bay Width Of About 3419 Mm, Operates On Single-Phase Or Three-Phase Power Supply, 50 Hz Frequency, Power Rating Of Approximately 3.0 Hp. Full Height Achieved In Less Than 45 Seconds, With An Overall Height Around 2844 Mm Including Automatic Arm Locks, Mechanical Safety Latches, And Overload Protection Etc. All Conforming To Is/Iso 13849 Standards.Preferably Ravaglioli Or Atselgi , Industrial-Grade, Floor-Operated Type Hydraulic Trolley Jack Suitable For Lifting Heavy Vehicles, Machinery, Or Agricultural Equipment Up To A Maximum Capacity Of 10 Tons. The Construction Shall Be Of Robust, All-Steel Design With Reinforced Chassis And Welded Seams For Durability. It Shall Have A Lifting Range From Approximately 150 Mm To 500 Mm, Operated By A Long Detachable Handle Providing Sufficient Leverage For Smooth Lifting. The Hydraulic System Shall Incorporate A Safety Overload Bypass System, Precision Machined Piston And Pump For Consistent Performance, And A Reliable Lowering Control Valve For Controlled Descent. The Jack Shall Be Equipped With Steel Swivel Casters, Wide Stance For Stability, And A Saddle Plate With Anti-Slip Surface. The Surface Finish Shall Be Rust-Resistant Enamel Or Powder Coating. The Unit Shall Comply With Relevant Is/Ansi/Ce Safety Standards, Factory-Tested For Rated Load, And Supplied Ready For Workshop Service.Preferably Ravaglioli Or Atselgi
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 4
16.
Defence #9545191 AOC
Tender For Provision Of Solar Power Plant At Sevoke Mil Station Under Ge Sevoke Road.; 2 Design, procurement, erection, installation, testing and commisioning including connecting to local utility grid; Grid connected solar photovoltaic plant 0.8 MW output peak capacity with net billing arrangement including Solar Photovoltaic Modules,DC Cabling, Module Mounting Structures (suitable for ground mountingwith and including Soil Investigation as per OEM recommendation, RCC foundation framed structure and other connected civil work duly vetted by IIT / NIT), Array Combining Boxes, ACDB, DCDB, Lightining Protection of SPV modules and other accessories, String Inverter as Power Conditioning Unit, Weather Station and Data Monitoring system (SCADA) all as per detailed specifications given in tender documents, latest MNRE/SECI/NISE/IREDA guidelines and directions, meeting the Make in India (DCR), consisting of all requisite accessories (BOS-Balance of system) and including the following main components (NOTE : The work shall be executed directly by OEM only through contractor.) Item Continued as 1.01 to 1.45 3 (A) Photo Voltaic Module: Mono-crystalline Silicon Bifacial Solar Photovoltaic Modules of minimum 550 Wp(module power and number of modules to be selected according to available area), having cell efficiency more than 20% under standard conditions, form fill factor more than 0.76, plant performance ratio > 75%, made of high transmitivity glass front surface and it shall give high encapsulation gain (transmittance above 90% and bending less than 0.3%). The modules shall have the following features :(a) The electrical parameters of SPV modules under standard test condition of irradiance 1000W/sqm, AM 1.5 Spectrum and temp 25 degree Celsius shall be as under : (i) Max Peak Power Pmax : 550 Wp or more (ii) Voltage at Max Power : > 40 V (iii) Current at Pmax :> 10A 4 (iv) Short Circuit Current :> 12A (v) Open Circuit Voltage :> 47 V (vi) Module Efficiency : > 20%(b) Rated output of the modules shall have positive tolerance of 3-5% and no negative tolerance is allowed.(c) It shall perform satisfactorily in RH 85% with temperature up to +85 degree C and should withstand wind of 200 kmph on the surface of panel.(d) PV modules shall be warranted for their output peak watt capacity, and it shall not fall of its initialvalue below 90% in first 10 year end and 80% after the end of 25 years.(e) Each module shall have RFID tag encapsulated with solar cell bearing following details (i) Name of Manufacturer of SPV Module (ii) Name of Manufacturer of Solar Cell 5 (iii) Month and year of Manufacturing (separately for cell and module) (iv) Country of Origin (both cell and module) (v) Peak wattage, Im, Vm and fill factor of the module (vi) Date of year of obtaining IEC PV module qualification certificate including the test lab issuing IEC certificate. (vii) Unique serial no of model no of module (viii) IV curve of module(ix) Other relevant information on traceability of solar cells & modules(f) The temperature coefficient of power for the module shall not be more than 0.50% per degree Celsius.(g) The module must have bypass diode of suitable capacity.(h) PV module must confirm to latest edition of IEC 61215/ IS 14286. In addition the modules must confirm to IEC 61730 Part I and II for construction and testing & safety qualifications and confirming to IEC 62804 PID.(j) It shall also be in conformity to latest minimum technical specification issued by MNRE/IREDA/SECI/NISE/ALMM from time to time. Modules should be of MNRE/IREDA/SECI/NISE/ALMM approved companies and as per latest IEC/IS standards. 6 (k) RFID reader is to be provided by contractor(l) Both PV cells and SPV modules shall be made in India (DCR).(m) Each structure should have angle of inclination as per the site conditions to generate maximum power. However, to accommodate more capacity the angle inclination may be reduced to 10 - 13 Degree until the plant meets the specified performance ratio requirements.(n) Fire Points with Fire extinguisher liquefied CO2 gas of capacity 10 kg and adequate qty confirming to relevant IS or ISI mark complete as recommended by manufacturer deemed to be included in the unit rate quoted.(o) Danger Board and Rubber mat as recommended by manufacturer deemed to be included in the unit rate quoted.(p) S&F Pressure Booster pump electrically operated with minimum 3 HP 02 Nos (Running+ standby) three Phase AC Supply motor and having head not less than 20 mtr, including PCC foundation civil wokrs and necessary cable required for connection in drawn in PVC conduit heavy duty/ DWC/Electrode pipe from existing nearest point to the motor starter panel including motor starter suitable capacity,PP-R IS-15801 (Polypropylene random co-polymer) pipe 3-layer 63 mm/50 mm/32 mm/25 mm inner dia (outer green coloured UV stablilized, middle black coloured UV stabilized and innermost layer white coloured with anti-microbial property) fusion welded grade PN-10 SDR-11 ( Pressure nominal 10KGS/cm2 ) having thermal stability for hot & cold water supply including all types of plain and brass threaded PPR fittings of any size such as elbow, tees, FTA and MTA etc laid in trenches with necessary exavation, removing and returning filling work and including all accessories from the new PVC tank cap 10000 Ltrs install at proposed site for cleaning of entire solar power plant system.(q) SPV Panel is to be fixed in such a way that lower portion of the Panel remains atleast above 1.5 mtr of finished reflecting surface and cost deemed to be included in the quoted rates. 7 (B) Junction Boxes: Junction boxes of suitable Nos (as per design)/OEM recommendations inputs and suitably rated out put having separate DCfuses for both (+)&(-) on input and isolator on output terminal for each string.Each junction box must have as pare input terminal.The junction boxes shall be dust and vermin proof and water proof made of FRP/ Thermo Plast with IP 65 protection in compliance with IEC 62208 and shall be UV resistant, fire retardant. It shall have surge protection and maintenance free earthing as per relevant standard. The junction box shall have suitable arrangement of the following: (a) The strings are required to be connected to the copper bus bar through individual fuses. (b) Provide arrangement for disconnection (DC dis-connection switch) for each SJB/ SCB. (c) To provide a test point for each sub group for quick fault location and to provide group array isolation. (d) Each array box shall be of relevant IEC standard. (e) Each array junction box shall have suitable bypass & reverse blocking diodes for minimum DC blocking voltage of 1000V with suitable arrangement of its connection. Reverse blocking and bypass diodes shall work for extreme temperatures and shall have efficiency of 99.98% confirmed by appropriate IEC standard. 8 (C) DC Cables: Suitable size of XLPE insulated tinned Copper cable (min 10 sqmm) of solar grade, 1100 Volts and UV resistant for outdoor installations confirming to IEC : 60227/15694 & 60502/ IS : 1554 (Pt I&II)) and shall be as under : (a) All cables and connectors must be as per IS/IEC standards and shall be able to withstand harsh environmental conditions including high temperature, UV radiations, rain, dirt, burial and attack by moss and microbes for 25 years and voltage as per latest IEC/IS. (b) All the cables / wires shall be provided with UV resistant printed ferrules for DC wires. (c) The size of the cable shall be such that average voltage drop at full power from PV module to inverter shall be less than 1.5%. (d) Cable batch No., Drum No, IS code and size and make shall be mentioned on every one meter or as per OEM practice. (e) The wiring of the module interconnection shall be in UPVC/HDPE pipe of suitable size. (f) The cost of interconnecting DC Copper cable, MS cable trays, MS cable trays suitable to accommodate Solar grade cables from SPV module to inverter are included in the item. 9 (g) Boring of holes under road, pavement, hard standing by trenchless technology (HDD) GI protection pipe up to 100 mm bore (dia), maximum 2.5 metre below of apron areain ant type of soilcomplete.Note : (i) All the precaution to be taken by the contractor before drilling the bore. The contractor has to take plan of existing cables any type and pipe line in existing area before drilling the bore. (ii) Any damage to existing cables any type and pipe line in the way of drilling the bore will be repaired and make good by the contractor within 24 hours. No extra cost will be paid in this account. (iii) Contractor has to get the survey of route, length and depth for boring before quoting the rate. (iv) Connected items like HDPE/PPR/DWCPE pipes, exavation, removing, return filing, channel, any type of metal work is not measured and paid separately under relevant items.(D) Module Mounting Structure (MMS) (Suitable for ground mounting on any type of soil condition) :Design, procure, fixing, support structure made of hot dipped galvanised steel with min 85 micron thickness including necessary PCC / RCC foundation and associated work (cutting, grounding, PCC filling, disposing waste material,etc., complete) and fixing mounting arrangement suitable for SPV modules so as it can with stand wind speed of 170 km per hour & minimum yield strength off 250 MPa. The mounting structure is to be installed on ground. Mounting structures to be so designed that maximum load is directly on ground. It shall also observe minimum space without sacrificing the out put of SPV panels & adequate spacing between the arrays shall be available for easy cleaning and maintenance. Nuts, bolts, protected from the atmosphere and weather mounting structure shall have to be adequately of Stainless Steel of grade SS316. 10 NOTES :- (a) Two numbers of anti theft fasteners of Stainless Steel on two diagonally opposite corners of each module shall be provided. (b) Module mounting structure shall be fitted to provide maximum generation. (c) MMS design shall be supported with Staddpro Report vetted by Third Party (Gov Institute) and submitted for the approval of the Accepting Officer. (d) The height of approved design MMS for solar power plant shall be as per latest MNRE/IREDA/SECI/ NISE guidelines. (e)Minimum grade of RCC M-25, design mix (using 20mm graded crushed stone aggregate includingTMT bar as per design, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete and other connected works as per design and OEM recommendation. Civil work shall be designed through approved consultant of MES as per latest MNRE/IREDA/SECI/ NISE guidelines and vetted by IIT / NIT.(E) Lightning Protection forentire Solar Power Plant (i.e PV Array, Inverter etc) : Design, procure and fix lighting arrestor system confirming toIS/ IEC-62305(Part1-4)on the ground. The air terminal shall be fixed at the top of MS pole with base so as to beat least two meter above the pole to be protected. Its height above 9 mtr level shall be depend upon the level of protection and protection radii required. 11 NOTES :-(i) The cost of all equipments, MS Pole, Copper strip upto earth test point,LA, etc., shall be deemed to be included in this item. (ii) The cost of sufficient earthing for lightning protection is also included in this item to be provided by Engr-in-charge. and no extra payment will be made to the contractor on this account (iii) The complete system shall include chemical earthing (as per OEM recommendations) and earth strip/cable etc for earth of SPV module, array, inverter,DC & AC boxes and for LA etc as per latest IS/MNRE/IREDA/NISE/SECI/ALMM specifications and guidelines.No separate cost of the same is included in the schedule and amount will be paid to the contractor on this account. In case of any dispute, decision of Engr in charge will be final, conclusive and binding to contractor. (The earthing shall be of copper earth plate and having specification as per SSR Item Sr 19474). Earth resistance shall not be more than 3 Ohms. (iv)Separate LA arrangement & the design document of the same shall also be submitted. (v) The protection against induced high voltage shall be provided by the use of metal oxide varistors and suitable earthing such that induced transient find and alternate route to earth. (vI) SPV Power Plant shall be provided with lightening and over voltage protection. (vii) Internal surge protection shall consist of three MOV type surge-arrestors connected from +ve abd +ve terminals to earth (via Y arrangement) 12 (F)Power Conditioning Unit: Procure, fixing, testing and commissioning of minimum 4 (Four) unitswith overall not less than 800 KW output on 11 KV AC supply, Solar-power inverter suitable for without DC power of Solar PV module/ array with AC output further feeding to grid confirming to IEC:61683 for efficiency, IEC:62109-1 or equivalent for safety and IEC:62093 for reliability. The input DC & output AC technical specification of Inverter are as under :Input (DC) (a) Max Absolute DC input Voltage : 1000 V (b) Start-up DC input voltage : 200 - 500 V (Default 420V) (c) Operating input DC voltage range : 200 - 1000 V (d) No of independent MPPT : One (e) MPPT input DC voltage range at Pacr : 180 - 1000 V DC (f) Max input DC Current : As per design. (g) AC grid connection type : 3Phase (4W + PE) (h) AC output power : As per design. (j) Max AC output Apperant power : As per design. (k) Max AC output Current : As per design. (l) Max AC fault current : As per design. 13 (m) Nominal Output Voltage : 800 Volts AC 3phase or as per the design of Solar Stepup Transformer (n) Output voltage range :± 10% (o) Output Frequency : 50 Hz ± 3Hz (p) Power factor : > 0.99 (q) Harmonic Distortion Current : < 3% (r) Efficiency : > 98% (s) Standby operation consumption : < 1.5 W(t) Operating temperature upto 85 degree centigrade (u) The Copper based inverter shall have minimum IP-67 protection, ground fault monitoring, reverse polarity protection, anti-islanding, DC reverse polarity, AC and DC short circuit current and over current, AC and DC over voltage and over temperature. 14 (v) The inverter shall adjust voltage and frequency levels to suit the grid. (w) The inverter shall be self commulated with Pulse Width Modulation (PWM) technology and shall be capable of synchronise maximum with in one min. (x) Maximum Power Point Tracker (MPPT) confirming to IEC 62093 shall be integrated in the inverter to maximise the energy drawn from the PV array (y) Monolithic design of inverter is not permitted. (z) Shall have anti-Islanding features. (aa) The inverter shall have suitble nos of protected inputs (asper design) and outgoing shall be protected by ACB/MCCB. (ab) The inverter should have MODBUS, PROFIBUS, ETHERNET common ports. (ac)The inverte rshall include appropriate self protection and self diagnostic features to protect itself and the PV array fromthedamageintheeventof invertercomponent failureor fromparametersbeyondtheinverterssafeoperatingduetointernaland/orexternalcauses. Invertershallhaveprotectionarrangementagainst ground leakage faults, over voltage, (SPD) & over current. Inverter shall have arrangement for adjustment for adjusting DC input current and shall trip against sustainable fault down stream and shall not restart till fault is rectified. (ad) The inverter should have provisions of Galvanic isolation, anti-islanding protection (IEEE 1547/UL 1741) equivalent IS and lightening. (ae) PCU must have the feature to work in tandem with other similar PCUs and be able to be successively switched ON and OFF automatically based on solar radiation variations during the day. (af) Minimum Warranty of Inverter- 12(Twelve) Years and defect liability period deemed to amended accordingly for the said item. 15 (G)ACDB : Outdoor type powder coated weather proof,vermin proof made out of CRCA sheet front open able door, lockingarrangement, including suitable working space in DCDB busbar chamber, cable box chamber including Copper busbar of designed capacity /bus raisers suitable capacities with PVC sleeves/tape RYB colour for phases identification, including all bus raiser shall be extend upto cable box chamber fixed on fibre insulation for RYB & neutral to all out going cable, confirming to IP-65 and fixed on wall / floor with control wiring with comprising cable gland brass, copper lugs etc. and comprising the following as per design :- (i) MCCB 4Pmicroprocessor based for outgoing (ii) MCCB 4Pmicroprocessor based for incoming (iii) AC type 2 Surge Protection Device (iv) Spreader Terminals as per requirement (v) Multifunction meter (vi) CT of suitable ratio(vii) Copper busbar chamber (ix) The earthing shall be of copper earth plate and having specification as per SSR Item Sr 19474).Earth resistance shall not be more than 3 Ohms. 16 (H) DCDB:- Outdoor type powder coated, weather proof, dust proof,vermin proof made out in CRCA sheet front open able door, looking arrangement, including suitable working space in DCDB busbar chamber,cable box chamber including copper bus raisers with PVC sleeves/ tape RYB coloursfor phase identification, including all bus raiser shall be extend upto cable box chamber, confirming to IP-65 and fixed on wall /floor with contral wiring with comprising cable gland brass, copper lugs etc. (i) MCCB as per requirement (ii) Fuse as per requirement (iii) Copper busbar chamber. (I) Weather Monitoring System Pyranometer : The pyranometer (ISO 9060 classification ) alongwith necessary assessories for measuring incidental solar radiation at horizontal and inclined plane of array. Specifications of the pyranometer shall be as follows :- (i) Spectral response : 031 to 2.8 micron,(ii) Time response (95%). Max 15 second 17 (iii)Nonlinearity + 0.5% (iv) Temperature response : - 2%(v) Tilt error <+/- 0.5% (vi)Zero offset themal radiation +7W/Sqm (vii) Zero offset temperature change + 2 W/Sqm(viii) Operating temperature range - O °C to 80°C(ix) Non stabillity Maximum - 0.8%,(x) Resolution minimum +/-1 W/Sqm (xi)Output Analog 4.50mA (xii) Digital RS 485(xiii) The earthing shall be of copper earth plate and having specification as per SSR Item Sr 19474).Earth resistance shall not be more than 3 Ohms. 18 (J)Balance of System(BOS) Items/ Components:TheBOSitems/componentsof theSPVpowerplants/systems deployed under this project shall conform to the latest edition with certificate of IEC or equivalent BIS Standards/MNRE specifications/ as specified in Para 1.01 of Minimal Technical Requirements/ Standards for SPV System/Plants to be deployed during this financial year under the programmes of MNRE available on MNRE website as on last date of quoting of tender. Notes:(i) The contractor must visit the site before quoting the rates for this item to assess the site condition so as to decide up on location and layout of SPV, placement of inverter, length of DC cables, lightning arresters, etc., complete. (ii) The contractor shall submit complete scheme including electrical diagram of the work, schematic diagram, SPV module layout, placement of LAs, Civil work, etc., complete as per IREDA/ SECI/NISE/MNRE/ALMM latest guidelines as applicable, Relevant IEC/IS norms to the GE for approval with in one month of date of commencement of the work. (iii) The rate quoted is deemed to be inclusive of the all protection system including surge, lightning arresters and necessary earthing all as specified and directed. 19 (K) Remote monitoring system (SCADA) for solar power plant complete with all electronic andelectricial partswith andincluding all necessary software and hardware etc to make fully functional connected to LED monitor (55 inches) with complete plant parameters as required and operate the system from remote and Other Accessories includingandThe system will be controlled from the main control room where all the data from different parts of the plant shallbe received, analyzed and action taken either manually or on auto as per the system design by OEM . The SCADA shallhave remote monitoring capability comprising with the following Items and with and including all connectedaccessories as per OEM recommendation complete:(a) Main SCADA control wall mounting panel complete with fixing arragnment like nut bolt, washers suitable size and connected items. (b) LED Moniter (55. inches) with mouse, key board, CPU (Minimum 1 TB storage alongwith 12 GB RAM, i7 processor), key pad and single phaseUPS 10 KVA with 12 Volt battery, 14400 Ah battery bank with rack and required battery backup should not be less than 4 Hrs inside control room.(c)“SCADA System shall be audited for Cyber Security by CERT certified firms at the time of commissioning. Subsequent cyber security audit shall be carried out after every 03 years and cost of audit and rectification shall be born by the contractor” 20 The Contractor shall provide following defined user access levels, unless otherwise instructed by the Engineer-in-Charge: -• Normal viewing only (default level) The default level shallpermit users to view al displays except those specifically assigned to a higher level of access.• Dally Access The daily access level shall allow viewing (ie default an printing at trend displays.• Operator Level (Remote Control) The operator level shall permit authorised users to access lower levels a and to carry out the following actions:- Perform control actions Acknowledge alarmsEnter or modify manually-entered data for inclusion in thereports.• Monthly and Yearly Data Archiving The level shall permit authorised users to access lower levels and shall provide the facility to download specific data to long ten data storage for archive purposes(d)The SCADA software shall be of a proven design and reliable, and conforming to industrial standards and shall: -• Support multiple makes of RTU/ Microprocessor controller/ transmitters and models and provide required software features needed to easily adapt a device whichshall not be supported as standard to the SCADA system. 21 • RTU/ PLC/ Microprocessor base controllers and transmitters shall have an expandable architecture and scalability to provide future capacity increases in SCADA system as well as meet present needs of the administration, provide multi-level security and password mechanisms to prevent use of the system by unauthorised persons. The access privilege of authorised users shall be defined separately and permission shall be provided to the users only to access areas concerning them, provide an on-line operatingenvironment.• Adding a new RTUI Microprocessor based Controller to the SCADA system or changing configuration of the existing RTUs/ Microprocessor based controller shall not result in stopping or hinder working order of SCADA system.• The Contractor shall specify maximum number of data which shall be achieved by the system without any performance loss. The Contractor shall conduct necessary tests to prove maximum number of data points achieved. The Contractor shall also be responsible to create additional data points necessary for conducting such tests. Any AutoCAD graphics shall be able to be converted to process diagrams and shall be re-loaded and operated after completion of all works and during tests.(e)The Contractor shall hand over to MES the SCADA and application software (as CDs or DVDs) necessary for re-loading software to the system in case of failures The CDs or DVDs shall be provided after making the necessary tests. The operating system ofrouters and work stations shall be of an architecture that provides a multi-tasking operating environment, and SCADA software shall also be multi-tasking. Therefore multiple tasks such as receiving measurement results from devices, displaying these results on computer screen. storing on a computer disk, sensing alarm conditions that may occur based on measurement results, and displaying them to users, generating reports from collected data, and printing them cut, transferring issued commands to Microprocessor controllers/ RTUs/ PLC, that SCADA software is supposed to execute shall be handled simultaneously without one task waiting for another. 22 To configureSCADA software or to change the system configuration, definitions shall be either defined directly by using a keyboard or another interactive tool or mechanisms that allow importing of configuration definitions from a text file created with a text editor. The database configuration shall be provided by means of an interactive program that contains menus or similar approaches and shall be easy to use The database configuration definition program, when required, shall be capable of extracting definitions related to the configuration from information created in text format to use as definitions for configuration The following shall be possible online without interruption or hindering of usual operations: -•Adding an RTU to the SCADA system.•Deleting an RTU from the SCADA system•Changing configuration information related to an existing RTU definition.•Modifying definitions in database containing information about measurement and control points.•Creating screen pictures which offer operators to monitor and control the SCADA system.•Similar configuration changes. 23 (f)SCADA software shall be upgradeable to new versions with an automatic mechanism to be provided by the Contractor. The old version of software shall be overwritten by new version without resulting in a change in any of the definitions created in previous version, nor disturbing the operational logic defined in previous version. Al! text being available on the screen shall be in English language The database shall be configured on-line when the SCADA system shall be in operation. The changes on existing definitions or new definitions related to database shall be made when the data collection n and control functions are being performed. The SCADA Software shall be operated using the database that shall be resident in the memory(g)Data Exchange The control system shall provide a method of real-time data exchange with different application programs like Geo Information System (GIS). relational database, third party spreadsheet packages, report generation and graphical simulation packages.(h) Historical Data Management An historical data management (HDM) system shall be provided for archive, storage and retrieval of operational data comprising field input data, manually-entered data and calculated points Archived historical data shall minimally include averages, minima and maxima for each analogue value compiled over hourly. daily and monthly time periods, with a minimum capacity of 1o00 points. The HDM system shall be capable of selectively increasing the rate of data capture based on events, such as process variable status, discrete inputs, or operator command. Minimum and-maximum data shall include the time and date of occurrence. Gaps in collected data caused by faulty instruments or control system equipment shall not be included in average). minimum and maximum compilations. 24 (j) Report GenerationThe system shall be provided with a report generator utility which shall enable authorised users to create, delete or modify report definitions The report definitions shall allow for retrieval of data from on-line database and farm historical data files and for formatting data for output to printer. The format of each report shall be definable by user to include the definition of static or background data, placement of data base values, number of significant digits of a value, date and time of report and calculated values(k)Graphic Display GenerationThe system shall be provided with an interactive on-screen graphic generation utility which shall allow an authorised user to create new graphic displays and modify or delete existing displays at any work station including those associated with the LCP/ outstations. The generation utility shall include an interactive linkage process allowing user to link symbolic, numeric and bar graph representations and data entry locations to dynamic data base variables. The graphic display system shall be capable of making full use of the VDU resolution in the composition and display of graphic information. Graphic symbols shall be definable by the user for display of static and dynamic data. The user shall be able to as5emble a library of symbols which shall be retrievable into any graphic display. Text and symbols shall be able to be enlarged, shrunk, moved, mirrored or related with reference to a given display. The system shall be able to represent dynamic analogue data on a graphic display as a variable-length, sizeable bar graph, as well as numeric text. 25 (l)DisplaysGeneral all displays, excepting those containing data derived from historical files, shall be completely displayed within two seconds of the operators request. Dynamic data shall be continuously updated while being displayed. All screen displays shall provide following displays which shall be fixed in their locations to normal operations:• Alarm banner window at bottom of the screen display showing last three highestpriority unaccepted alarms. Where the system allows contents of banner to be limited (eg by user name or group) then the selection criteria applied shall be displayed with the banner.• Main display area for user selected displays e.g. mimics, alarm lists, etc.• System dialogue banner window at bottom of the screen shall display relevant system information such as error message and user prompts 26 •A day, date and time indicator shall be able to show local time an alarm bannerarea shall be included on all displays which provide information regarding most resentalarm events. The system shall allow operator to obtain details of most recent alarm event from any operational screen display through direct operation using a maximum oftwo keystrokes or selections. The system shall allow the operator to obtain a print of any display, including graphics through use of a standard system command. Screen displays shall appear identical incorporated form Dynamic data contained on a display shall not change during screen print Such that a snapshot of conditions is portrayed. Each display shall include time of day in hoursminutes and seconds and date in day, month and year format.•A facility shall be provided which allows paging to related displays through the use of ‘page forward or backward keys, or through the use of pick points(m) Suitable size of HT & LT XLPE insulated screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 11000 Volts and 1100 Volts grade with stranded aluminium / copper conductor of size as per OEM recommendation and approved design ISI markedincluding cable glands, lugs, jointing kit etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc.with all fixing & connecting accessories and necessary earthwork, civil work deemed to be included in quoted rates of the above items.(n)Generic Displays.The system shall produce various generic displays automatically 27 Metering arrangements: (A)Suitable bi-directional metering arrangements with recording facility shall be provided as per the norms of WBSEDCL. The metering arrangements must have feature to measure and record, (i)Parameters of KW, KWh, KVAR, voltage, current, PF and any other metering required to determine efficiency and efficacy of the system. (B) LT 3 Phase 4 Wire Electronic Tri vector Meter with CT ratioshould be as per capacity of SPV plant. (i) Standard: IS 13779:1999 / CBIP 88 (ii) Accuracy: Class 0.5 (ii) The metering arrangement shall have inbuilt Solar PV Plant synchronisation features. (iii) Reference Voltage - 3x240 V (iv) Basic Current (Ib)- 5 A (v) Maximum continuous current (Imax) - 10 A (vi) Rated Frequency (variation) - 50Hz (±5%) 28 (vii) Power consumption:- Voltage circuit: Less than 1.5 W and 10 VA per Phase at reference voltage, reference temperature and reference frequency Current circuit: Less than 1 VA per phase at basic current, reference frequency and reference temperature (viii) Display type: 8 digit 7 segment backlit LCD display, not less than10 mm character height (ix) Display in the event of Power Failure: Internal battery back-up for LCD display (x)Communication port: Galvanically isolated Optical Communication port for data transfer through either CMRI or remote device or both is providedwith RS 485 for DLMS protocol (C) CT/PT operatedenergy meter with following features (i) True four quadrant metering (iii) Time and day metering with maximum demand registration and automatic billing (iv) LCD display with announciators for various critical events (v) Scroll lock feature for continuous display of a desired parameter on display (vi) High resolution energy display mode for dial test (vii) DLMS protocol for meter reading, with option to remote reading port. 29 (viii) Advanced event detection features for voltage, current and magnetic influence (ix) Meter reading in absence of mains, using internal battery. (x)Power Manager Device Nano type with 4 inverter support with energy monitoring, zero export control, Load Management having RS-485 communication port, ethernet including RS 485 cable core size 0.5-1.5 Sqmm to establish communication between inverters, SCADA and sensor as per OEM recommendation with and including all connectedaccessoriesdeemed to be included quoted rates.(xi) Digital WIND SPEED SENSOR withminimum 3 cup Anemometer range 0 to 70 Mtr/ Sec distance constant 2.5 Mtrs output TTL Pulses output proportional to wind speed and diameter of cup 50mm with brass housing and stainless stell shaft(xii) WIND DIRECTIONSENSOR with wind vane and sensing vain coupledto linear endlsess potentio meter IP 67, range 0-357degrees, operating temperature -40 to +60 degrees celsiuswith brass housing and stainless stell shaft and aluminium vane complete 30 (xiii) AIR TEMPERATURE SENSOR withRTD sensing element PT100 mounted inside a weather shield duly coated with weather proof reflective white paint , range -40 degree to +60 degree celsius with nylon body housingwith weather shield and brass stem to mount the sensor, includingpower requirment 5 Volt DC complete. (xiv) MODULE TEMPERATURE SENSOR Model PT 1000 measuring range -40 Degreeto + 80 Degree Celcius with suitable ouput as required and directed on site and mounting on RTD encapsulated in suitable housing including connecting cables as required complete.(xv)Tipping Bucket Rain Gauge with Magnet and Red Switch type Sensing, rim diameter 203 mm and collecting are 335 MM SQ, Rain gauge shell made up of FRP bucket and mounting made up of stainless steel SS316 and unlimted capacity,including connecting cables as required complete.(xvi)SOLAR Radition Sensor ARN 8101 with 72 element thermo pile sensor and spectral range 0.3 to 3 Micro Mtrs and sensitivity 20 Micro Volt/ W/M², range 0 to 1500W/SQM & output 0 to 25 milli Volt and operating temp -10 to 70 Degree Celsiusincluding connecting cables as required complete with all fixing arrangment and necessary civil work complete with including all connectedaccessories as per OEM recommendation/Designcomplete: 31 (L)Step up solar transformer (800 volt/11 KV)” - Design,procure,erection, installation, testing and commisioning including connecting to local utility grid :Oil filled Type 3 phase, 50 Hz, ONAN cooling type, vector group of appropriatetype, number of load voltage Ratio: number of Phases / Freq.: 3 Phase / 50 Hz., Sealed type Copper wound Transformer with Off Load Tap Changing Arrangement on HV side in steps of 2.5% , +5% to -10% having cable end boxes on HV side suitable for 3 Crore X 300 Sq. mm. XLPE cable of 11 kV grade on HT side and LV side complete with all accessories like buchholz relay, Oil temperature indication, winding temperature indication and alarm etc preferbly DMCR Protection Relay i/c first filling of filtered dehydrated K Class natural Ester Oil bioTransol (as per IS 16659) and confirming to IS 1180 and losses shall be as energyefficiency Level 3 only & 100% load phase, with an impedence of 6.25% i/c as per specification below complete in all respects as required at site. Design ambient to be considered as 50 Deg C.All the balance parameter like temp rise, Basic insulation level, flux density etc shall be strictly in accordance with IS 1180 Part - 1 only including necessary earth work, PCC plinth foundation etc.Heat Run Test is the mandotary test for each Transformer.Standard: The equipment shall conform to the latest edition of applicable standards as follows. In case of conflict between applicable standards and this specification, this specification shall govern.• IS 2026 Standard for Oil filled Transformer• IS:3639 for Fittings and Accessories• IS:2099 for Bushings > 1000 V• IS:7421 for Bushings < 1000 V• IS:1271 for Electrical Insulation classified by Thermal stability• IEC 62770 Natural Ester Oil• CBIP Guidelines 32 (xvii) CORE : Transformer shall be double wound, core type with low loss, non-ageing, high permeability PRIMEGRADE, CRGO with M4 Grade or Better, perfectly insulated and clamped to minimize noise and vibrations. Followings should be Mandatory for any manufacturer: -(a) Transformer shall be of BOLTLESS core design.(b) Core shall be purchased Directly from Manufacturer or from their accreditedMarketingorganization of Repute & not through any agent. Bidder has to submit manufacturer’s name during bidding having sufficient credential & Core has to be purchased from the approved manufacturer.(c) Stage inspection of the core shall be done at manufacturer’s premises & inspection call shall be given with following Documents: (i) Invoice of the supplier (ii) Mill’s test certificate (iii) Packing list (iv) Bill of landing & Bill of Entry certificate by customs(d) Transformer manufacturer should have in-house core cutting facilities for proper control & monitoring of quality & to avoid mixing of Prime core with Second grade /defective core materials. Transformer Manufacturer should have in-house slitting Machine so that core is cut to width & stacked with minimum air gap thus ensuring Burr level less than 10Microns.(e) Core shall be procured from one of these reputed Manufacturers : Posco / Nippon/ Novex/ Ak Steels.(f) The insulation structure for the core to bolts and core to clamp plates shall be such as to withstand a voltage of 2000V for one minute. 33 (xviii)Tank:Tank should be of corrugated wall construction type. The exterior of tank and other steel surfaces exposed to the weather shall be thoroughly cleaned and have a priming coat of zinc chromate applied. The second coat shall be of an oil and weather-resistant nature, preferably of distinct colour from the prime and finish coats. The final coat shall be of a flossy, oil and weather resisting non-fading paint of specified shade. The interior of the tank shall be cleaned by shot blasting and painting with two coats of heat resistant and oil insoluble paint.Winding:(a) Winding shall be made with 99.9% pure electrolytic grade copper, insulated with thermally upgraded paper (Insulation Class A / Conductor Turn Insulation-Class E).The HV & LV winding should be able withstand thermal and mechanical stress in the event of short circuit.(b)Winding shall be carried in dust free area(c) The completed core and coil assembly shall be dried in vacuum and shall be immediately impregnated with oil after the drying process to ensure elimination of air and moisture within the insulation.Oil type: TransformerTransformer oil shall be as per IS-335:1993. It shall be natural/synthetic ester oil. The material safety Data Sheets (MSDS) for the Transformer oil shall be submitted by the bidder along with the offer Temperature Indicator:One set of winding temperature indicators with necessary current transformer, heating coil and a detector element and one set of oil temperature indicator with maximum reading pointer shall be mounted locally so as to be readable at a standing height from ground level. Each of the above indicators shall be provided with necessary contacts for alarm and trip: (a) Oil Insulation class : K class. It should also exhibit safety against fire hazards 34 (b) Cooling : ONAN(c) Vector Group: to be decided during design.(d) Percentage Impedance (Z%) 6.25 %.(e) Transformer Losses:as per IS 1180 - Level 1(2021)(f) Taps on HV for HV variation : +5 to -10 % in steps of 2.5% each (g) Termination (HV): Cable End box for11 KV cableof suitable size(h) Termination (LV): Cable connection(j) The transformer shall be supplied with following fittings:(k) Lifting lugs and Jack lifting pad support(l) Earthing terminals - to be decided during design. 35 (M)Earthing :The complete system shall include chemical earthing of required quantity for step-up Transformer (as per OEM recommendations) and earth strip/cable etc for earth of SPV module, array, inverter,DC & AC boxes and for LA etc as per latest IS/MNRE/IREDA/NISE/SECI/ALMM specifications and guidelines.No separate cost of the same is included in the schedule and amount will be paid to the contractor on this account in case of any dispute decision of Engr in charge will be final and binding to contractor. (The earthing shall be of copper earth plate and having specification as per SSR Item Sr 19474).Earth resistance shall not be more than 3 Ohms. 36 IMPORTANT NOTE FOR SOLAR POWER PLANT CONTRACT (COST DEEMED TO BE INCLUDED IN QUOTED RATES :-(1) The item specification and details given are for guidance purposes only and are likely to vary with modified / higher specification than that specified in the BoQ based on detailed site survey, solar potential assessment, design approval etc keeping the quantity of Solar inverter (PCU) and Solar Transformer same as in the BoQ. The items as per the finalized and approved design and specification, including make, shall be provided by the contractor without any extra cost to the department. All makes should be as per the latest MNRE approved list of makes and models.2.Cost of preparation of DPR design vetting from NISE/MNRE approved Institute and net billing arrangement (as per WBSEDCL) is deemed to be included in the quoted rate.3.The contractor shall submit complete design of Solar power plant, Schemetic/line drawings, detailed mounting structure array layout drawings alongwith SBC report based on the soil investigation as per OEM recommendation, Single line diagram with and including project reportand connected document shall be submitted by OEM through contractor prior to commencement of the work for approval of Accepting officer and subject to the drawing and designduly vetted by IIT/NIT (for mounting structure only) and vetted by NISE/ SECIfor entire scheme of Solar Power GenerationProject including evacuation and Net Metering arrangement complete before recommendation by GE for approval of the accepting Officer. 37 (i) The scope of works involves engineering, procurement & construction (EPC) of entire Solar Power Plant of capacity 0.8 MWp.4. The entire work shall be executed directly by OEMonly through contractor and contractor has to submit the MoU with OEM (agreement period for 25 years of entire Solar Power Plant Project) prior to commencement of work and same shall be approved byGE. 5. Boring of holes under road, pavement, hard standing by trenchless technology (HDD) GI protection pipe up to 100 mm bore (dia), maximum 2.5 metre below of apron areain any type of soilcomplete.Note : (i) All the precaution to be taken by the contractor before drilling the bore. The contractor has to take plan of existing cables any type and pipe line in existing area before drilling the bore. (ii) Any damage to existing cables any type and pipe line in the way of drilling the bore have to berepaired and made good by the contractor within 24 hours. No extra cost will be paid in this account. (iii) Contractor has to get the survey of route, length and depth for boring before quoting the rate. (iv) Connected items like HDPE/PPR/DWCPE pipes for entire Solar Power Plant Project, exavation, removing, return filing, channel, any type of metal work is deemed to be included in the quoted rate. 38 6.Cost of comprehensive maintenance as per OEM recommendation alongwith cost of spare parts required during 5 years of defect liabilty period after completion of Ph-I is deemed to be included in the quoted rate.7. Bidders attention is drawn to pre-bid conferance with department and also visit the site prior to bidding and other factor required as per OEM recommendation deemed to be included in quoted rates.8. The contractor has to carryout Pre-commissioning test of solar power plant including stepup transformer by CEI/SEI. The necessary tools and plants required for inspection of the plant shall be arranged by the contractor.and costsare inclusive in quoted rates.9. Contractor needs to know the irradiance of the location at the project before quoting. The contractor will design DCR (Make in India) for entire Solar Power Plant according to irradiance of the project location and efficiency of the components to produce the desired peak value as mentioned in the schedule i.e. 800 KW output on 11 KV AC supply and inject to the proposed RMU 11 KV. 10. During the execution of work any type of damage by elephant or monkey manance, contractor is fully responsible for protection of all solar power plant equipments including connected items i.e. PV Module, Inverter etc. No claim will be sought from the department. 39 11. All SCADA related activities viz. cables till SMBS and inverter and the requisite software and hardwarefor control room shall be included in the quoted rate.12. Vegetation Growth should be controlled by use of Deweeding Chemicals deemed to be included in Quoted Rates.13. Adequate Water Storage Facility of capacity 10000 Ltrs PVC Tank 5 Layer (with guarantee of 10 years after physical completion of work) on PCC Platform including suitable foundation for cleaning of PV Modules and suitable water drainage facilitiesfor both (Rain Water and Cleaning Water) from proposed site to existing drainage chamber is deemed to be included in the quoted rate.14. Solar Transformer fed from the Inverter should not be having odd harmonics (certificate needs to be required before physical completion of work).15.The Shutdown duration of Inverter should be monitored and recorded and analyzed. 40 16. The SPV Power Plant will be capable of generating 800 kW AC Output atleast once in a year and the AC Output of the plant will be not less than 90% of initial output by the end of 10 yearsand not less than 80% of the initial output by the end of 25 years.17. The Contractor shall operate and maintain Fire Protection System and safety equipments for the entire Solar Power Plant for 10 Years and cost of the spare is deemed to be included in the quoted rates.18.The firefighting system for the proposed power plant for fire protection shall be consisting of:a) Portable fire extinguishers in the control room for fire caused by electrical short circuitsb) Sand buckets in the control roomc) The installation of Fire Extinguishers should conform to TAC regulations and BIS standards. The fire extinguishers shall be provided for control room housing, PV array installation.19.Solar Components shall not be connected to LAN, WAN, or any Internal Data/OPS nw. 41 20.Sys with Bluetooth, GSM, Wi-Fi, or any Telemetry features should be avoided, unless explicitly cleared monitored.21. Finalization Of Feasibility Report, Design, Engineering, Transportation, Storage, Insurance, Civil Works, Erection, Testing & Commissioning etc., ensuring net-billing as per state net billing policy, quality control of grid connected.22.The Comprehensive Maintenance of SPV Plant would include wear, tear, overhauling, machine breakdown, insurance and replacement of defective modules, Inverters/PCU, spares, consumables & other partsas pe OEM reocmmendation and specification for 5 (Five) years under DLP of Phase-I..23.The Contractor shall arrange technical vetting of the plant during execution by the Cyber/INT officer and training by Unit Technical Pers till defect liability stage of Phase-I. 42 24.a) An energy meter (for net-billing) shall be installed between the solar Grid-tied inverter and the building distribution board to measure gross solar AC energy production (the Solar Generation Meter). The Solar Generation Meter shall be of the same accuracy class as the DISCOM service connection meter or as specified by local regulatory requirements. Separate for two different buildings.b) The bidder must take approval/NOC from the Concerned DISCOM for the connectivity, technical feasibility, and synchronization of SPV plant (if required).c) Contractor shall be provided system software (Cloud) for data hosting of Solar Power Plant with the Government approved agency and also audited by CERT-In (Computer Emergency respose team-India) is deemed to be included in the quoted rates. 25.a) Two sets of Engineering, electrical drawings, and Installation and O&M manuals are to be supplied. Bidders shall provide complete technical datasheets for each equipment giving details of the specifications along with make/makes in their bid along with the basic design of the power plant and power evacuation, synchronization, along with protection equipment is deemed to be included in the quoted rates. 43 b) All test and calibration certificates, wherever applicable.26. The bidder shall take entire responsibility for the electrical safety of the installation(s) and personnel, including connectivity with the grid and follow all the safety rules & regulations applicable as per local guidelines and regulations, etc. Insurance of the installers (of the vendor) working abroad is mandatory.27. (a) The bidder shall take entire responsibility for the electrical safety of the installation(s) and personnel, including connectivity with the grid and follow all the safety rules & regulations applicable as per local guidelines and regulations, etc. Insurance of the installers (of the vendor) working abroad is mandatory.(b) The contractor will carry out fortnightly, monthly, quarterly and annual maintenance as per Proforma of Appendix here-in-after respectively. In case the contractor fails to carry out the above maintenance following penalty per Solar will be imposed. 44 (i) Not carrying out maintenance fortnightly- Rs 2500.00(ii) Not carrying out maintenance Monthly- Rs 5000.00(iii) Not carrying out maintenance quarterly- Rs 7000.00(iv) Not carrying out maintenance annually - Rs 10000.00(c) The Contractor shall be responsible for ensuring production of 800 kW AC output of electricity at the injection point of RMU atleast once in a year from the SPV plant. In case the output is less than 800 kW AC unit, it will be deemed as under-designed plant. The contractor will be responsible for making good the shortfall by repair / replacement of the SPV Plant free of cost. Delay in this regard will attract monetary penalty to be amounted for the period wef very next day of the completion of Phase-I to the date of completion of rectification / replacement by multiplying the maximum value of units less generated than 800 kW AC for every day with the prevailing rate of electricity tariff of WBSEDCL Rate of electricity in West Bengal is Rs 6.52 per unit as in Sep 2025.(d) Maintenance and supervision shall be done by trained men for the safe operation of Solar’s contractor shall carry out fortnightly servicing including adjustment lubrication, repair of replacement fo parts if necessary. In addition to fortnightly servicing contractor’s senior mechanic of foreman shall carryout the inspection as per maintenance schedule and make necessary entries in the proforma attached here-in-after duly signed by Contractor & Engg-in-Charge as applicable kept in the switch room for this purpose. It will be the responsibility of the contractor to see that the maintenance schedule book is maintained properly by their senior mechanic or foreman. They shall promptly attend and call back & shall not be kept pending for more than 4 hours unless it has the prior approval of the Garrison Engineer. 45 (e) For any repairs/ replacement of Solar the contractor shall always be aware of time factor following are the fixed time (including Sunday/Holiday) for repair/replacement of parts/components/ accessories which shall be adhered to :- (i) Minor repair/ replacement- 4 hours (ii) Major repair/ replacement - 1day(f) The decision of the GE regarding Minor/Major repair shall be final conclusive and binding. In case of failure on the part of the contractor to keep the solar’s in running condition within the stipulated period mentioned in above the contractor is to pay penalty charges as mentioned below subject maximum of 10% of the total contract value and after that measurement will not be considered for the same defective Solar till it is in satisfactory working condition :-(i)Upto 12 hours @ 2000/-(ii) Above 12 Hours and up to 24 hours @ 5000/-.28. RFID Tag scanner of reputed make shall be provided by the contractor is deemed to be included in the quoted rates.29. Existing Room at 33 KV Switch Yard shall be used for SCADA/ Solar equipment/Control Room. 46 30. Surface preparation and laying of light yellow/white coloured interlocking tiles of appropriate thickness under the whole area of PV module array to make a reflecting surface for bifacial Solar PV module alongwith periodical water sprinkling arrangement for cooling of interlocking tiles is deemed to be included in the quoted rates. 31.The complete system shall include chemical earthing (as per OEM recommendations) and earth strip/cable etc for earth of SPV module, array, inverter,DC & AC boxes /LA etc as per latest IS/MNRE/IREDA/NISE/SECI/ALMM specifications and guidelines is deemed to be included in the quoted rates. Earth resistance shall not be more than 3 Ohms .32. The mounting steel structure shall be as per IS 2061-1992 and galvanizing as per IS 4759 and should withstand WIND Load as per relevant IS Code/NBC.33.Soil Stabliztion testing certificate needs to be required before completion of physical completion of work (Phase-I) so that the performance of the PV Plant is not affected in Highly Soiled areas for minimum 25 years. 47 34. M&O (Phase-II) should be finalize at the planning stage itself. The important point are as under:- (a) The thermal imaging of pv panel should be taken once a year for checking its health including hot spots.(b) The cleaning cycle of panel should be fixed as per the ratio of short circuit current falling below 0.9. The cleaning provision shoul be made available before evacuating the power.(c) The shutdown duration of inverter should be monitored and recorded and analyzed 48 Supplying, Installation, Testing & Commissioning including design, manufacture and testing at works of indoor type , IP 4X ,floor mounted metal clad, 11 KV VCB panel board totally enclosed & fully interlocked, Horizontal drawout, Horizontal isolation type breaker as per IEC-62271-100/200, as amended up to date and additional specifications, having capacities as mentioned below, single break, trip free mechanism, motor charged and manually/electrically closing breaker suitable for use on 11 KV,3 Phase, 50Hz A.C. supply with STC 25 KA for 3 Sec.Internal Arc for AFLR 25kA at rated voltage for 0.1s at individual compartments i.e. Busbar, VCB and cable compartment.complete with self contained, fully interlocked, rack in and rack out mechanism, air insulated and encapsulated copper bus bars of 800 Amps capacity, breaker featured with mechanical ON/OFF indicator with hand trip device, spring release coil, shunt trip coil and auxiliary switch of 8 NO + 8 NC andequipped with following switch gears and accessories.The panel shall be complete with following switchgear and accessories. The structure of the switchgear must be fabricated using steel sheets coatedwith Alu-Zinc (Aluminium Zinc alloy)/PRINTED CRCA All major sub-components (switchgear, relays, meter & vacuum interrupters) shall be of same make. VCB and vacuum interrupters shall be designed for 100 short circuit operations at full short circuit of 25KA. Breaker shall be roll on floor type/ CASSET TYPE. Separate earthing truck shall be required for each bus earthing & cable earthing. Earthing truck shall be so designed that it is impossible to earth a live. It shall be provided with capacitive voltage divider and complete with audio visual annunciation, one for each panel. Item Continued as 2.01 to 2.04 49 INCOMINGS & Outgoing VCBs :Type : Air insulated VCB, autoreclosing, system voltage :- 11kV + 5%, 50 Hz+ 5%, 3 phase, rated voltage : 12kV, rated current : 800A in 40 ° C ambient, Short time rating for 3 sec : 26.3 kA, Short Circuit Making Current : 65 kA, insulation level (PF rms/ impulse peak) : 35 kA/75kA, System Ground : Solidly Earthed,Duty Cycle : 0 - 0.3 sec - CO - 3 min - CO, Break/ Make time :- Not more than 5 Cycle, Range for Auxiliary voltage for Closing / Tripping / Spring Charging : 85-110%/ 70-110%/85-110%. of rated voltage. The VCB must withstand 10000 mechanical, & 100 at rated short circuit current. The breakers should have auxiliary contact 6 No+ 6 NC, in minimum. The used Breakers will comply with IEC 62271/ IS 13118. Qty. - 3 Nos (1 no Incomer & 1 outgoings)Busbar: Rated Current : 800A @ 40°C ambient, Material : Silver Plated /Tined , High conductivity elecrolytic Copper Bus Bar sleeve :Heat Shrinkable PVC Sleeve with joints having full voltage soft PVC shroude Short time rating for 1sec :26.3kA -1 setCurrent Transformer:Voltage class: As specified in Circuit breaker ; Type: cast resin type, Dual core, Dual Ratio , Barden :10VA; Class insulation : Class E or better . Protection core: 5P10, Metering : 1.0 , Short time rating for 1 sec :26.3kA Ratio :300-150/1-1, 7 setsBus Potential Transformer: Rated Voltage : Primary - 11000 / ✓3 , Sec -110✓3; Type : Cast resin , draw out type, 3- phase , 3-limb complete with HV fuses . Barden : 100VA per phase ; Class of insulation : Class F or Better , Accuracy Class: 1.0;Rated Voltage factor : 1.2 continuous, 1.5 for 30 Secs. PT shouldbe drawnout type and serivce continuously shall be indepandent of Breaker trolly position...1set 50 Relay for Control & Protection: Numerical Type IDMT Relay (50/51, 50N/5IN) with two elements for overcurrent and earth fault having settings 50% to 200% for overcurrent and 20% to 80% for earth fault in equal steps with time and current settings and high set instantaneous unit. Additionally, condition monitoring CB wear, condition monitoring CT supervision, disturbance recorder, undervoltage & over voltage protection, trip circuit supervisioncan be measured through the relay. The device shall support webserver/web HMI through which we can monitor and control the relays over a ethernet Lan network. Licenses for theprogramming software shall be provided free of cost.The numerical relay shall have large mimic-based LCD screen display . .The relay shall have 8 Digital inputs and 8 Digital Outputs and one additional watchdog ouput.The device has to aloe controlling of min. six objects (circuit breakers, disconnectors and grounding switches). Controlling has to be done by “select-execute” or “direct control” principle. Controlling has to be possible by: through local HMI, remote communication, via digital input or via function key. Events has to be readable to SCADA systems, front panel or by setting software.The sample rate of the recording has to settable to 32samples/cycle.The devices shall provide storage up to events 2000 based on the resolution.The device shall support following communication protocols: Native IEC 61850 ed1 & ed2, Modbus TCP. The IEC 61850 communication has to support peer to peer communication (GOOSE) if requiredThe IEC 61850 interface must be able to configure through setting software. Also the same setting software has to be able to generate ICD filesThe device shall have KEMA IEC61850 edition 2 certificates - 3 sets. High Speed Master Trip relay VAX31- 3 Set, Ttrip circuit supervision relay-VAJH13-3 set6 Window Annunciation Facia . with ACCEPT, RESET & TEST Push Button - 3 set . Auxillary relay for Transmission faults (VAA33)- - 3 Set 51 Metering: Meters: 1-NosUL&CE Multifunction Digital meter displaying Voltage, Amps, kWh, kW, P.F., Active, reactive, apparent energy , disturbance direction detection, Individual harmonic up to the 63rd harmonic. at least 256 samples/cyclewith ethernet Port with inbuilt webserver and complying to IEC 61557-12, IEC 62053-22 certified by third party laboratory.Temperature Monitoring Sensor for the Three Phases of Incomer VCB Panel :Supply, installation, testing & commissioning ofthermal monitoring system to be provided to detect abnormal temperatures due to faulty connections and to prevent equipment B19damage. The switchgear shall have wireless temperature measurement sensors at all critical points:(a) 3 nos. foreach phase at incoming side cable joints The wireless temperature sensors installed on conductors shall be :(i) Installed with direct contact to hot point, to achieve accuracy of +/- 2°C(ii) Self-power (no auxiliary supply, no battery)(a) communicate wirelessly(c) Operate from -25°C to 125 °CThe system shall allow 2 configurable thresholds (pre-alarm and alarm). This system shall have integrated algorithms enabling to anticipate as early as possible an abnormal temperature, before damage occur (strong predictive capacity) and generate alarm through SCADA/monitoring software. Thermal sensor shall beself powered by the network current. Temperature data is sent via Zigbee wireless communication to provide high performance and accurate thermal monitoring. The sensor is secured to the connection point and is in direct contact with the measured point. Smartphones or tablets (with a Zigbee communication dongle) can be used with our Thermal Connect mobile application to scan data locally and can replace the need of periodic infrared scanning. Thermal sensors should comply to following standards:1 EN/IEC 61010,2010 2. UL 61010-12, 20123. ETSI EN 300238, 2012 V1.0.1 4. IEEE 802.15.4, 2013 52 Power Pack shall be with 220Volt AC Input & 24 volt DC continuous output suitable for closing /tripping indication of HT panel boards with 2nos 12Volt 100AH maintenance free batteries, chatging unit for trip system complete with suitable capacity dogital MFM connections with 2.5sq mm FRLS inaulated copper conductor cable etc as required.-4 set.The 11 KV HT Switchboard of 1 panel,shall bewith all accessories, interconnections,internal wiring, labels, space heaters etc. complete as required.3 panels shall be mechanically interlocked in such a way that only one operates at a time and multifunctional digital meters shall be interconnected and programmed in such a way that total consumption will come in one meter summating both of them.Note: 1. Quotated rates shall be inclusive of construction of foundation for the installation of VCB as per OEM drawing.2. The equipment shall be tested by SEI post sucessful installtion and report shall be submitted to this office. 53 Design, Manufacturing, Supply, Installation, Testing and Commissioning of 3 way 12 kV rated Ring Main Unit ofwith Fault Level 21KA 3 sec internal ARC 1 sec for tank and cable box , consisiting of 630A12 kV rated , 2 nos motorized type VCB as incomers & 1 load break switch as outgoings with metering modules along with necessary Earth Switches,battery and battery charger for shunt trip arrangement andMotor and other auxiliary circuit operation, HT CopperBus bar with current density not more than 1.6A/sq. mm as per detailed description as follows: RMU Construction: The switchgear and busbar shall all be contained in a stainless steel enclosure filled with SF6 at 0.3 bar (300 hPa) relative pressure to ensure the insulation and breaking functions. Sealed for life, the enclosure shall meet the sealed pressure system criterion in accordance with the IEC 62271-1 standard (§ 3.6.5.4): a volume for which no further gas processing is required during its entire expected life”. In addition, manufacturer shall confirm that maximum leakage rate is lower than 0,1 % / year. It shall provide full insulation, making the switchgear insensitive to the environment (temporary flooding, high humidity...), IP67 degrees of protection in accordance with recommendation IEC 60529 § 14.2.7. No SF6 gas handling required at site. Thus assembled, the active parts of the switchgear shall be maintenance-free and the switchboard shall be low-maintenance. The switchgear operating mechanism shall have an IP2X protection and cable chamber shall be IP55, Over all IP protection shall be IP55 . The tank shall be made of at least 2mm unpainted stainless steel. Item Continued as 3.01 to 3.05 54 VCB is the preferred dielectric medium for MV RMUs. Oil filled switchgear will not be considered. RMU shall be in accordance with IEC 60376.Any accidental overpressure inside the sealed chamber will be limited by the opening of a pressure limiting device in the lower part of the enclosure. Gas will be released to the rear or the bottom of the switchboard away from the operator and internal arc tested for both cable and tank for 21KA 1sec AFLR with test conducted with minimum 3 functions TankNumber of mechanical operations of Circuit breaker 2000 O/C , Number of electrical operations at full loop current for LBS: 100 O/C , Number of electrical operations at full loop current for CB: 2000 O/C,. Manufacturer shall provide type test report to prove compliance with IEC 62271-200 Annex A, Internal arc classification class AFL with 21kA 1s for the enclosure. Make of the RMU, vaccum intrtupter , relay & meter shall be of same OEM. All the test certificate shall be in the name of the OEM only . If there is any name change / acquisition by other OEM happened for the RMU then test cerificates shall contain the new OEM name only.HT System : 3 phase -3 wire , HT Fault level21 kA, Power System earthing - solindly earthed at up stream source, HT Copper Bus with Short Time Curent rating 21 kA for 1 Sec ( 3Sec), Continuous current rating at least 630 A. tank and cable chamberof RMU must be IAC rated for 21 kA for 1 Sec AFLR. Design ambient to be considered as 40 Deg C.HT Circuit Breaker :(i) There shall be 1nos.load break switches as incomings and 2 nos 12 kV rated VCBas outgoing ( total 3 nos.) . The circuit breakers shall be fixed type. All of the switchgear shall be capable of withstanding this current without any damage being caused, in accordance with the recommendations IEC 62271-1 and IEC 62271-200.Loss of service continuity class: LSC2(ii) The Circuit Breaker must be rated for 12 kV ( nominal Voltage), 28 kV/75 kVp ,3 Phase, 50 Hz, Short Circuit Fault Level of 21 kA for 3 sec. 55 (iii) No. Of Close Coils - 01 no. operable at 24 V DC (85% - 110%)/ Spring Assited Closing, No. of Trip Coils - 01 nos. ,operabale at 24 V DC ( 70% - 110%) for shunt trip.(iv) Provision for supervision of the shunt Trip Circuits for the Trip Coils to be provided. (v)Switchgear classification: PM class(vi) Loss of service continuity class: LSC2(vii) Duty Cycle : O – 3min – CO – 3min – CO, Vacuum Circuit breaker shall be of M1, E2, C1 duty and capable for minimum 50 short circuit breaking operation at full short circuit level.(viii) STC rating 21 kA for 3 Sec (for Vacuum Interrupter).(ix)Vacuum Interruptor must be hermetically sealed and must comply IEC 60056 ( along with latest amendments). Vaccum interrupter shall be of same make as RMU(x)Circuit Breaker to be equipped with Suitable tripping arrangement with push button, Mechanical counter to assess the total number of operations of the breaker, Mechanical ON / OFF indicator, Auxiliary switches, Auxiliary Contacts( at least 2 NO + 2 NC of Class 2 category), Emergency trip push button.(xi) The Operating mechanism shall be spring charged motor operated/ spring assisted as per OEM type tested design type with Spring Charge Universal motor operable on 24 V DC / 230 V AC.(xii)Suitable monitoring of Bircuit Breaker status ( ON, OFF, Trip, CB Spring charged if applicable), Trip Circuit Healthy / Unhealthy, DC healthy/unhealthyto be provided using (xiii) Voltage Presence Indicator shall be provided against each HT circuit ( against each VCB) on line side for knowing the presence of line enerzisation status.(xiv)Number of Mechanical operations at full rated current for breaker: 2000 O/C 56 HT CT /PT : Load Break Switch - 11 KV, 630A, 21KA for 3sec Motorized Load break switch; with built in line side manual earth switch. Earthing should be completed within 2 operations only(i.e 1. Main switch - OFF, 2. Earth switch - ON). LBS shall have 3 positions, open or disconnected, closed and earthed, and will be constructed in such a way that interlocking prevents unauthorized operations. For earth switch, manual opening and closing will be driven by a fast-acting /snap action mechanism, independent of operator action. LBS and earth switch shall have a min of 1000 (M1) mechanical operations ,and 5 nos closing operations at rated SC current. LBS should have 100 electrical operations at rated current. LBS & Earth Switch should have separate apertures for operation.i) One set of 03 nos. ( for 3 phases) dual core Cast Resin CTs for Eachincomer VCBcomplying with IEC:60185 & IS 2705 ( along with latest amendments) , Core -1 - 400-200/1 A , 2.5 VA, Cl 0.5 for metering ; Core-2 - 400-200/1 A, 2.5 VA , 5P10 for Protection.ii) 01 no. of 03 phase Dual Core PT forHT bus ( 11 kV)with protection HRC fuseCore 1- 11kV /√3 / 110V/√3, Cl 0.5s, 50VACore 2- 11kV /√3 / 110V/3, Cl 3P, 50VA(iii) Multifunction Meter:2 Nos. 3 phaseDigital Multifunction Meter6400NGwith Voltage, Amps, kWh, kW, P.F., Active, reactive, apparent energy , disturbance direction detection, Individual harmonic up to the 63rd harmonic. at least 256 samples/cyclewith ethernet Port with inbuilt webserver and complying to IEC 61557-12, IEC 62053-22 certified by third party laboratory.for each VCB panel ( 96 mm x 96 mm) , Flush mounted, Class 1 conforming to IEC 62053-22 ( along with latest amendments). 57 Protection Relay: (i) 2 Nos. of Numerical Type Self-powered IDMT Relay(50/51, 50N/5IN) with two elements for overcurrent and earth fault having settings 50% to 200% for overcurrent and 20% to 80% for earth fault in equal steps with time and current settings and high set instantaneous unit. Relay should communicate on Modbus RS-485.(ii) Each VCB must have separate Anti Pumping Relay / Antipumping feature through motorization circuit.Fault Passageindicator: The FPI shall facilitate quick detection of faulty section of line. The fault indication may be on the basis of monitoring fault current flow through the device. The FPI should be self-powered and should have internal lithium battery for external indication and setting of FPI in the absence of current.The FPIs shall include: Fault detection - Phase to phase and Phase to earth faults.One potential- free output contacts for hardwiring to RTUs. On this basis, the SCADA/DMS will be able to monitor phase / earth fault condition.Local fault indications - LCD display on FPI front panel along with LED indication on front panel of RMU enclosure.Multiple reset option : End of time delay (Adjustable from 2 to 16 Hrs)Remote reset (Via potential free input contact of FPI)Manual reset (Reset button on front panel of FPI)Automatic reset on current restoration.The characteristics of the FPIs shall include: Phase fault thresholds configurable from at least 100 to 800 A,Earth fault thresholds configurable from at least 20 to 200 AMultiple number of steps for adjusting phase and earth fault thresholds. Fault current duration range configurable from at least 40 ms to 100 ms in 20 ms steps and further 100 ms to 300 ms in 50 ms steps. Variations with respect to these characteristics may be acceptable as long as they prove applicable and provide the same or better flexibility. 58 EARTHING : The cables shall be earthed by an earthing switch with short-circuit making capacity, in compliance with IEC 62271-102 standard. The earthing switch can only be operated when the switch is open. The switch and earthing switch operating mechanism shall have a mechanical endurance of at least 1000 operations. Integrated line side Earth switches shall be provided in each HT Circuit. ( against each VCB)RMU Bushing & Cable Termination: It is preferable to have all bushings accessible from the front of the RMU. Bushings along the sides or the rear of the RMU are not acceptable.For each cable compartment, the bushing shall be at the same height in order to facilitate a possible reversal of the cables. The bushing should be conveniently located for working with cables specified and allow for the termination of these cables: - 630 A M16 bolted connectors for switch-disconnectors and vacuum circuit breakers functions.The profiles of the cable connection bushings shall be in compliance with IEC-60137 standard. Cable clamps:A cable clamp arrangement must be provided for all network cables terminated on the RMU.Provision for Cable Entry: There shall be suitable provsion for Cable entry from bottom through 3 mm thick CRCA steel thick detachable gland plate along with provision for termination of 2 runs of 3 c X 300 Sq mm 11 kV (E ) , XLPE insulated Aluminium Cables (for HT side) and at LT side runs of cables matching with outgoing MCCB current rating.Note: (i) Quotated rates shall be inclusive of foundation for the installation of VCB as per OEM drawing.(ii) The equipment shall be tested by SEIaftersuccessful installtion and report shall be submitted to this office and cost deemed to inclusive in qoated rates 59 M&L for water proof, 3 core PVC insulated and PVC sheathed, copper conductor cable of size 1.5 sqmm, 1100 Volts grade including PVC conduits properly fixed on steel poles using GI wire for electrical connection of street light fittings, complete all as specified and directed. 60 Supply and fixing junction box having protection dust proof, acid resistant, shock proof, fire retardent self extinguisher for outside installation with knockout entry for cable of size 10 - 25 sqmm andminimum size 295x195x95 mm with terminals, with and includingbrackets for street light pole mounting andone 6A MCB SP complete all as specified and directed. 61 M&L for Advanceencapsulated compound based Chemical earthing CPRI tesed maintenance free , pipein -pipe technology upgraded(Zinc & Alloy coated). , Zinc & Alloy coated (80 -100) microns with pure zinc (99.9%) & Alloy coating (200-250) microns. Earthing system conforming IS 3034. The outer and inner pipe should be 76.2 mm and 41.9 mm dia respectively of3 mtrs long zinc coated with additional special alloy coating 300 mm on top side for additional protection of the terminal . The annular space between the pipes to be filled up with Compactfill (CF) (Crystalline Conductive) mixture which should bemachine pressed in the pipes not disintegrate or collapse when outer pipe corrodes . The inner pipe should be extended with terminals for connectivity.The job includes digging the pitsin any type of hard densesoilof min size 1000 X 1000 X 3050 mm depth taking out excavated soil, lowering/ placing thethe pipe in pipe earth electrode in pit in center ,filling of pure conductolite back filling compound (BFC Conductolite) having excellent moisture retaining capacity in 300 mm around the electrode(minimum 4 bags of 25 KG per pit per unit) or more qty of backfillcompoundas required to fill around the the elctrode in 300 mmin circumfrance of electrode . Contractor has to fill the remaining portion of pit withlow resistivity soil (agriculture soil) free from stones etcs, to be bring from out side defence landas the soil resistivity ofStn is very high and mixed with min 3 Bags of 50 Kg each of Bantonide clay. The BFC should be eco friendly it should not contain envernmently hazardous material/metal having ROHS certification from NABL accredited lab.The earth pit should be provided with a FRP earth pit cover for protection and safe guard of terminals. The material of earth electrodeshould have good electrical conductivity & anti corrosion property in wide range of soil conditions. The job also include M & L for in PCC(1:3:6) typeC-1 around the FRP cover for support and foundation and colouring the PCC work withdesired colour.completeall as specified and directed. Item Continued as 6.01 62 Note : (i) Design of earth electrode should be of pipein-pipetechnology .(ii) Contractor have to submit literature of earth electrode and get the make approved of GE before procurement.(iii) The earth electrode shall be CPRI tested to withstand short current test for 60kA rms for 1.0 second and 150kA for peak current.(iv) Contarctor has to fill pure back fill compound conductolite all around the earth electrodein 300 mm bore up to full depth of bore.(v) Contractor shall refill the pit with low resistivity soil (agriculature soil ) free fron stone etc and mixed with 06 bags of Bentonite of 25 Kg each to achive the low resistance values. (vi) copper strip will be laid below 60 cm from ground level and connected to test point through plinth protection. This Earthing System used for VCB and RMU only. For Solar Power Plant Earthing System is already deemed to be included in quoted rates.(vii) Necessary cost of repair to plinth protection and connected plate and earth continuity conductor by providing 2 x brass nuts bolts and brazing of joints,bringing argiculture soil from out side defence land and cost of 6 x Bags of bentonidedeemed to be included in the item rate.(viii) Contractor has to clear the side and disposed off the excavated soil from pit on completion of work. 63 SAFETY EQUIPMENTSSupply and fixing Rubber hand gloves suitable for 11 KVas per OEM recommendationcomplete all as specified and directed. 64 S&F for glass framed Shock treatment chart both in Hindi & Englishand connected accessoriescomplete all as specified and directed. 65 S&F for dry powder chemical type 4.5 kg fire extinguiser with clamps and connectedaccessories ISI Marked complete all as specified and directed. 66 S&F for single line diagram, schematic diagrams etc. of A1 size on suitable Aluminium sheet including lamination etc. as required as per OEM recommendationcomplete all as specified and directed. 67 Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in soft/loose soil complete all as specified and directed. 68 Excavation in trenches, not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth for foundation, manholes, laying of UG cables/pipes etc. not exceeding 10 Sq.m on plan and getting out in soft/loose or any type of soil complete all as specified and directed. 69 Removing excavated material (soils) to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed. 70 Returning filling in, soft/looseor any type of soil including spreading leveling watering and ramming complete all as specified and directed. 71 Excavation in post holes (or similar holes) in soft/loose soil each n.exc 0.50 cum, getting out,returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, watering, and removing surplus soil to a distance n.exc 50 m and making good surface all as specified & as directed. 72 M&L for RCC M-20, design mix (using 20mm graded crushed stone aggregate), including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed. 73 M&L for steel tubular swaged poles complete with cast iron base plate, finial taper plugs, bolts, nuts & screws as specified type 410 SP-31, 9.0 meter longinclusive of two coats of aluminium paint over one primer coat of red oxide zinc chrome primer including preparation of surfaces complete all as specified and directed.NOTE : (a) The poles shall confirm to IS - 2713 & each component pipe shall be ISI Marked & confirm to IS - 1161. (b) Necessary earthwork, PCC etc. shall be measured & paid separately under relevant items of work. 74 S & F LED Street lights nominal power 90 Watt, LED of Make Osram; Bridgelux ; Philips; Nicha; Cree; Samsung, LED wattage of minimum 3 watt each and Maximum 5 watt each, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, lumen efficacy of minimum 120 lumens per watt, built-in integrated electronic LED driver, output open /short circuit protection, phase to phase protection, over voltage protection, surge voltage protection upto 4 KVs, protection grade IP 66, CRI greater than 80%, CW available CCT of 5700K, power factor of minimum 0.95, pressure die-cast aluminium alloy housing with polyester powder coated metallic silver finish after phosphochromate treatment, life span of minimum 50000 working hourswith IK10 and L70 on including fixing at any height and including wiring using three core PVC insulated, PVC sheathed, flexible stranded copper conductor FR-LSH cables suitable for outdoor use, 1.5 sqmm as per IS 694: 2010 complete all as specified and as directed.(i) If connection.cable from pole Juction box to street light and street light bracket up to 2 mtrs be included and measured in unit rate item, Beyond 2 mtrs of length to be paid seperately under respective items.(ii)At location where street lights/flood light are connected through overhead conductor, connection cable from light fitting to overhead conductor is deemed to be incl in the item rate. (iii) All LED street light/flood lights shall be properly connected with earth dolly provided with fittings and steel poles earth bolt.(iv)All LED lights have replacement warranty of 5 years from the date of completion of the contract accordingly condition 46 of GCC (IAFW-2249) shall be amended to extent mention above. Contractor has to submittwarranty certificate from manufacturer . Payment of light fitting will be released after receipt of 3 year replacement warranty certificate from manufacturer.(v) The LED lights will replaced bythe contractor free of cost in the case of manufacturing defects and Failure due to electrical impact if not connected properly with earth. Hence it is contractor responsibility to connect the light fitting earth wire and shall be grounded properly.(vi) The contractor shall submit the surge protection certificate and Type test certificate LM 79, LM 80 for luminaries from LED manufactutre. 75 M&L for Cement concrete (1:4:8) type D2, (Using 40mm graded crushed stone aggregate) as in foundations of poles and stay, filling and mass concrete complete all as specified and directed. 76 M&L for plain cement concrete (1:3:6), type-C2 (40mm graded crushed stone aggregate) as in foundation, filling and mass-concrete, coping etc for pole foundationwith and including necessary formwork complete all as specified and directed. 77 M&L PCC (1:2:4) type B2 (using 40 mm graded crushed stone aggregate) as in foundations, filling and mass concrete and copingwith and including necessary formwork complete all as specified and directed. 78 Material & labour for earthing complete with copper earth plate electrode 600 mm x 600 mm x 3.15 mm thick burried directly in ground (Earth pit not less than 4 mtr deep below ground level) with top edge of the plate not less than 3.25 mtrbelow ground level connected to copper strip 20 x 3.15 mm as earth lead by brass nut bolts washer including brazing the copper strip with copper plate as shown in electrical plate No 3 connected to earth test point including necessary excavation for earth pitin hard dense soil, rocky / disintergate rock, filling charcoal and salt around the plate in layers , filling the pit with low resistivity agriculture soil free from stones, to be bring from out side defence land and mixed with Bentonite , (4 bags of 25 Kg each ), construction ofinspection pit ( earth pit chamber) of brick work of size 600 x 600 x 600 mmwith PCC copping of 1 :1.5: 3, 12.5 mm aggregate A1 with MS sheet 2.8 mm plate cover on frame ofangle iron of size 40 x 40 x 5 mm with , wire mess, funnel, test point, 40 mm dia GI protection pipelightgrade and20 mm GI peforated pipefor wateringetc complete and testing on completion. The electrode and lead shall be of copper all as specified and directed by Engr-in-charge (Copper strip upto 7.5 RM will be included in the item rate and copper strip beyond 7.5 RM will be measured seperately Item Continued as 22.01 79 NOTE :-(i) Contractor shall uselow reisistivity fresh agriculture soil , mixed with 4 x Bags of bentoniteclay of 25 Kg each for refillingthe pit to achive the desired resistance.(ii) copper strip will be laid below 60 cm from ground level and connected to test point through plinth protection(iii) Necessary cost of repair to plinth protection as per existing specification and connected plate and earth continuity conductor by providing 2 x brass nuts bolts and brazing of joints,bringing argiculture soil from out side defence land and cost of 3 x Bags of bentonitedeemed to be included in the item rate.(iv) Contractor has to clear the side and disposed off the excavated soil from pit on completion of work.(v) Contractor has to submit test report of earthing after completing the earthing.(vi) Bentonite clay should be Conf to IS 6186: 1986.(vii) The cost ofCopper strip of size 20X3.15 mm from top of earth plate upto 7.5 meter above ground level is deemed to be included in the unit rate of above item.and copper strip beyond 7.5 RM will be measured seperately.(viii). All the joints in copper strip and connection with Earth Plate to be welded through brazing and in addition by proving brass nut bolt and washer are deemed to be included in the unit rate. (ix) Cost of brazing / welding and nut bolts are deemed to be included in the unit rate. (x) Cost includes removal of excavated soil upto a distance of 100 mtrs. 80 Supply and fixing copper strip of size 20 x 3.15mm as earth continuity conductor or main earthing lead fixed on V typeporcelain insulator, 4 BM, heavy duty ( ceramic bus bar supportinsulator off whitecolour ofsuitable for mounting strip of 20 mm wide x 3.15 min thick) saddle to wall, buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 20 x 3.15 mm copper strip brazingto each joints and connected with by providingbrassnut boltsand washer including test point all as specified and directed by Engr in Charge. Note : Insulators shall be provided on every 50 cm. (Minimum 2 x insulators to be provided in every 1 x metre of strip and rate of the same deemed to included in quoated rates) 81 M&L sand cushioning (dry) in trenches for protection of UG cables (below, above and around the cable laid in trenches) of 230mm spreding thickness and consolidated (punned) upto 180mm thickness, complete all as specified and directed. 82 Supplying and laying un-reinforced precast concrete cable cover, class HV, type 1 with peak, size 300mm x 180mm x 40mm complete all as specified and as directed. 83 M&L for GI pipe 100 mm bore, light grade with all fittings and fixtures (ISI Marked), laid in trenches, under road or fixing on wall/ pole /crossing drain /nallah etc. of bore complete all as specified and directed. 84 Supply, laying, jointing & testing XLPE insulated screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sq mm 4 core ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc.with all fixing & connecting accessories complete all as specified and directed. 85 Supply, laying, jointing & testing XLPE insulated screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 4 core ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc.with all fixing & connecting accessories complete all as specified and directed. 86 Supply, laying, jointing & testing XLPE insulated screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sq mm 4 core ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc.with all fixing & connecting accessories complete all as specified and directed. 87 Supply, laying & testing PP-R IS-15801 (Polypropylene random co-polymer) pipe 3-layer 63 mm dia (outer green coloured UV stablilized, middle black coloured UV stabilized and innermost layer white coloured with anti-microbial property) fusion welded grade PN-10 SDR-11 ( Pressure nominal 10KGS/cm2 ) having thermal stability for hot & cold water supply including all types of plain and brss threaded PPR fittings of any size such as elbow, tees, FTA and MTA etc laid in trenches complete all as specified and as directed.Note:The contractor shall submit 15 Years warranty certificate against leakageand defect liabilty period deemed to amended acordingly. 88 Supply, laying & testing PP-R IS-15801 (Polypropylene random co-polymer) pipe 3-layer 32 mm dia (outer green coloured UV stablilized, middle black coloured UV stabilized and innermost layer white coloured with anti-microbial property) fusion welded grade PN-10 SDR-11 ( Pressure nominal 10KGS/cm2 ) having thermal stability for hot & cold water supply including all types of plain and brss threaded PPR fittings of any size such as elbow, tees, FTA and MTA etc laid in trenches complete all as specified and as directed.Note:The contractor shall submit 15 Years warranty certificate against leakageand defect liabilty period deemed to amended acordingly. 89 S&F for 63mm (OD) PP-R Gate valves (brass insert)and connected acessories complete all as specified and as directed. 90 S&F for 32mm (OD) PP-R Gate valves (brass insert) nd connected acessories complete all as specified and as directed. 91 M&L for hard core of gauge not exceeding 63mm with broken stone or boulders, deposited, spread and levelled in layers not exceeding 15cm thick, watered and rammed to a true surface complete all as specified and directed. 92 Providing and laying 60 mm thick factory made cement concrete interlocking paver block of M35 grade conforming to IS 15658-2006 made by block making machine with strong vibratory compaction, of approved size, design & shape, cast in rubber mould, glossy finish of approved colour, laid in required colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge. 93 S&F for RCC pipes of 600 mm dia, NP-2 laid and jointed complete with collars complete all as specified and directed. 94 S&F for 250mm bore Flue pipes of mild steel sheet, black, in suitable lengths as approved by GE and fixed to walls complete all as specified and directed. 95 M&L for Brickwork with fly ash bricks (modular bricks ), straight or curved on plan exc 6m mean radius, built in cement mortar(1:6) complete all as specified and directed. 96 Material and labour for plastering 15 mm thick (in two coats of 10 mm and 5 mm thick) on fair faces of brick work or concrete surfaces (on vertical surfaces) in cement mortar 1:4 with integral water proofing compound finished even and fair complete all as specified and as directed. Note: - Water proofing compound will be deemed to included in qoated rates. 97 M&L for applying three coats of white wash on newly plastered wall surfaces including preparation of surface complete all as specified and directed. 98 S & F hot rolled low tensile structural steel of grade E165 as per IS 15911: 2010 as in hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embedding in concrete and screwing etc. Wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar works complete all as specified and as directed. 99 S & F hot rolled medium and high tensile structural steel of grade E165 as per IS 15911: 2010 as in framed work such as grills, grating, etc., with ends of bars of shouldered and/or riveted, or forged into spikes, framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework water tanks and similar work complete all as specified and directed by Engineer-in-charge. 100 S&F flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed. 101 S&F MS screw bolt (machine made) with hexagonal or square heads at one end and screwed the other or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exc. 5 cm and n. exc 10 cm long, diameter of neck 5 to 10 mm complete all as specified and directed. 102 Supply and fixinggalvanized steel chain link fence fabric of mesh size as approved , made out of 4 mm nominal dia of mesh wireconforming to IS 2712-2003 and having zinc coating of type heavy as laid down in IS-4826 including line wires/ binding complete all as specified and as directed(A Board of Officers under the orders of GE shall be convened to ascertain the weight per square metre of galvanized steel wire chain link fencing brought at site by the contractor against each lot of materials). 103 S&F 10mm round bars Fe-410-W (Gde-250) quality-A or Fe-290-(Gde-E-165) as in stiffner to hold the chain link fencing fixed with angle iron post inclucinding necessary welding and fixing arrangement at ends complete all as specified and directed . 104 S&F Galvanised, 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steelpins, etc. complete all as specified and directed . 105 Material and Labour for applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer on new steel and iron surface exceeding 10 cm in width or girth including preparation of surfaces complete all as specified and directed. 106 Material and Labour for applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer on new steel and iron surface not exceeding 10 cm in width or girth including preparation of surfaces complete all as specified and directed. 107 Materials and Labour for reinforced cement concrete M-20design mixin columns; pillars; piers; posts; struts etc,complete all as specified and directed. 108 S&F for Mild steel TMT bars 10mm dia and over, conforming to Fe 500 D, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed. 109 S & F for mild steel TMT bars 6 to 8 mm dia, conforming to Fe 500 D cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, stirup,hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. 110 M&L for construction of valve chamber with MS sheet cover 3mm thick with angle iron) frame of size 50 x 50 x 6mm and locking arrangements including painting one coat of primer followed by two coats of black sysnthetic paint including excvation and earth work in any type of soil,PCC (1:4:8) type D2 in foundation ,PCC benching 1:2;4 type B-1 ,PCC (1:5:8) block masonry 20 cm thick in cement mortor (1:6),10 mm thick plastering in CM 1:4 ,PCC bed in (1:3:6) and coping 50mm hick in cement concrete 1:2:4 type B1 using 20mm stone aggregate including necessary formwork,paintin one coat of red oxide and two coats of bituminious black paint on all steel surfaces as specified and as directed of sizes 800mm x 800mm x800mm (internnal dimensions) complete all as specified and as directed. 111 Sch A Part-II (Phase-II) 112 Providing Services for Manning and Operation of Solar Power Plant 0.8 MWp near 33 KV receiving stationat Sevoke Mil Station for FIRST YEAR after completion of Ph-I of the subject work with oneskilledcategory Electricianhaving certificate of Surya Mitra from NISE) for twoshifts of 8 hour, one helper (semi-skilled category) in two shift of 8 hrs eachcontinuous operation (including Sunday/Holiday) to maintain sub station in/out side Panels, Invertor, DC junction box, VCB as specified, including daily and weekly check up including cleaning of PV modules complete with suitable cleaning cloths etc , upkeeping the installation operational and in health condition, having own conveyance and communication system like mobile etc. complete, for Solar Power Plant with all minor consumable and expendable items and labour and tools for smooth and efficient operation complete all as specified and directed by Engineer-in-Charge. Make of spare parts / equipments of the Solar Power Plant :- Same as installed in the preceding phase of the work.Repair or replacement ofdefective components or spare parts will be carried out free of cost under DLP and comprehensive Maintenance as per OEM recommendation up to DLP period included in BOQ item No. 1.00. The Contractor may submit his claim for every months on pro-rata basis subject to condition 64 of IAFW-2249 (General Conditions of Contracts)The bidders shall ensure that the quoted amount for O&M is not less than minimum fair wages i.e. quoted amount is not less than the prepriced amount i.e. Rs 17,92,949.00. If quoted amount is less than the prepriced amount, same will be amended to pre-priced amount.Amount so adjusted will be deducted from quoted amount against Sch A Part-I i.e. Item No. 1.00 of BOQ. Quoted Amount of tender as a whole will remain unchanged due to this adjustment. Item Continued as 56.02 to 56.06 113 NOTES :- In addition to and Manning, Operation and Maintenance of Solar Power Plant, the following works will also be carried out by deputing addl manpower where required, to the entire satisfaction of Engr-in-Charge.(a) Minor repairs and preventive maintenance required to ensure serviceability and efficiency of complete MRS complex including supply of HT 11 KV fuse wire of proper sizeand minor spares such as nut, bolts, spring, lock nut of VCB/OCB as per sample, broom, duster, grass cutting tools, phawara, pick axes for cleaning/grass cutting of complete at Sub Stn Complex. 114 (b) Record of activities such as voltage / current / PF / Energy consumed / temp of transformers, break downs, day to day maintenance of Solar PV Plant etc.(c) The contractor shall ensure that all safety precautions are strictly exercised by the staff employed by him.Adherance to IE rules and statutory rules in vogue must be ensured.The contractor shall be fully responsible for any mishap that occurs due to any fault of the employee or due to non adherance of safety norms.(d) Record of activities such as attendance register, duty roster, pay distribution register of the whole staff employed by the contractor.(e) The electrician staff employed by the contractor shall be ITI holder with four years experience. 115 (g) Security lights within the complex will be operate by the tenderer. (h) The under mentioned tool kitwill be provided at site with person on duty :-(i) Electrician tool kit such as screw driver set, tester, test lamp, cutting plier, insulation tape, fuse wire of required size. (ii) Tongue tester(iii) HT megger(iv) First aid box (v) Shock treatment chart duly framed(vi) 33 and 11 KV Hand gloves(vii) 33 KV discharge rod withcopper chain(viii)) Helmet -02 nos(ix) Suitable Footwear - 02 nos(x) Cotton protective clothing with long sleeves duly embossed with GE Sevoke as directed. The tenderersquoted rates shall be deemed to be include the cost of all above provisions and nothing extra will be paid on any account. 116 (xi) The Bidders shall abide by the latest Labour rules and minimum wages Act. Wagespaid by the bidders to the persons employed shall not be less than the minimum wages fixed by the state/central government from time to time whichever is higher. (xii) The Bidders is responsible for insurance, EPF, ESI, Bonus, Labour welfare cess et., as applicable and shall be paid to the workmen as per existing Labour rules/ Acts/ regulations and rate quoted shall be deemed to be included for the same.(xiii) Dress Code : The bidders shall provide the workmen with Dark Blue Colour uniform {formal pant & T-shirt} with labels showing/ printed i.e. Name of the firm and designation on front and on the back of the T-shirt along with protective clothing, Industrial safety shoes, protective gears like helmet, safety belt etc..(xiv) Supervision and attending of all incoming & outgoing Solar Power Plant equipment metering equipments & monitoring to loads & other parameters of incomming & outgoing feeders & maintaining log sheet and attendance sheet. 117 INSURANCE: The Bidders shall also insure the workmen employed on the job.The Bidders shall be responsible for all Accidents/Injuries happening to the workmen. Any accident causing minor/fatal injury, partial disability due to any untoward incident or non-adherence to safety and IE regulations or fault in maintaining of internal electric supply system or on account of any mishandling/ wrong operation/ lack of knowledge of safety precautions or on account of any circumstances beyond his/ their control, the bidders shall be solely responsible for settling all claims of compensation to the deceased, falling which department will have a right to recover any sum indicated/ claimed by Labour commissioner/court authorities. No claim whatsoever will be entertained in this regard. No compensation is payable by the department on this account. Bidders shall provide first aid boxes to meet any emergency situations. 118 All as perBOQ serial item No 56.01 to 56.06 as mentioned here-in-before but for SECOND YEAR after completion of Ph-I of the subject work .NOTE :- (a) The bidders shall ensure that the quoted amount for O&M is not less than minimum fair wages i.e. quoted amount is not less than the prepriced amount i.e. Rs 18,75,076.00. If quoted amount is less than the prepriced amount, same will be amended to pre-priced amount.Amount so adjusted will be deducted from quoted amount against Sch A Part-I i.e. Item No. 1.00 of BOQ. Quoted Amount of tender as a whole will remain unchanged due to this adjustment. 119 All as perBOQ serial item No 56.01 to 56.06 as mentioned here-in-before but for THIRD YEAR after completion of Ph-I of the subject work .NOTE :- (a) The bidders shall ensure that the quoted amount for O&M is not less than minimum fair wages i.e. quoted amount is not less than the prepriced amount i.e. Rs 19,61,175.00. If quoted amount is less than the prepriced amount, same will be amended to pre-priced amount.Amount so adjusted will be deducted from quoted amount against Sch A Part-I i.e. Item No. 1.00 of BOQ. Quoted Amount of tender as a whole will remain unchanged due to this adjustment. 120 All as perBOQ serial item No 56.01 to 56.06 as mentioned here-in-before but for FOURTH YEAR after completion of Ph-I of the subject work .NOTE :- (a) The bidders shall ensure that the quoted amount for O&M is not less than minimum fair wages i.e. quoted amount is not less than the prepriced amount i.e. Rs 20,51,671.00. If quoted amount is less than the prepriced amount, same will be amended to pre-priced amount.Amount so adjusted will be deducted from quoted amount against Sch A Part-I i.e. Item No. 1.00 of BOQ. Quoted Amount of tender as a whole will remain unchanged due to this adjustment. 121 All as perBOQ serial item No 56.01 to 56.06 as mentioned here-in-before but for FIFTHYEAR after completion of Ph-I of the subject work .NOTE :- (a) The bidders shall ensure that the quoted amount for O&M is not less than minimum fair wages i.e. quoted amount is not less than the prepriced amount i.e. Rs 21,46,848.00. If quoted amount is less than the prepriced amount, same will be amended to pre-priced amount.Amount so adjusted will be deducted from quoted amount against Sch A Part-I i.e. Item No. 1.00 of BOQ. Quoted Amount of tender as a whole will remain unchanged due to this adjustment. 122 All as per BOQ serial item No 56.01 to 56.06 as mentioned here in before but for SIXTH YEAR after completion of Ph-I of the subject work .NOTE :- (a) The bidders shall ensure that the quoted amount for O&M is not less than minimum fair wages i.e. quoted amount is not less than the prepriced amount i.e. Rs 22,46,564.00. If quoted amount is less than the prepriced amount, same will be amended to pre-priced amount.Amount so adjusted will be deducted from quoted amount against Sch A Part-I i.e. Item No. 1.00 of BOQ. Quoted Amount of tender as a whole will remain unchanged due to this adjustment. 123 All as per BOQ serial item No 56.01 to 56.06 as mentioned here in before but for Seventh YEAR after completion of Ph-I.NOTE :- (a) The bidders shall ensure that the quoted amount for O&M is not less than minimum fair wages i.e. quoted amount is not less than the prepriced amount i.e. Rs 23,51,386.00. If quoted amount is less than the prepriced amount, same will be amended to pre-priced amount.Amount so adjusted will be deducted from quoted amount against Sch A Part-I i.e. Item No. 1.00 of BOQ. Quoted Amount of tender as a whole will remain unchanged due to this adjustment. 124 All as per BOQ serial item No 56.01 to 56.06 as mentioned here in before but forEight YEAR after completion of Ph-I.NOTE :-(a) The bidders shall ensure that the quoted amount for O&M is not less than minimum fair wages i.e. quoted amount is not less than the prepriced amount i.e. Rs 24,61,315.00. If quoted amount is less than the prepriced amount, same will be amended to pre-priced amount.Amount so adjusted will be deducted from quoted amount against Sch A Part-I i.e. Item No. 1.00 of BOQ. Quoted Amount of tender as a whole will remain unchanged due to this adjustment. 125 All as per BOQ serial item No 56.01 to 56.06 as mentioned here in before but for Ninth YEAR after completion of Ph-I.NOTE :-(a)The bidders shall ensure that the quoted amount for O&M is not less than minimum fair wages i.e. quoted amount is not less than the prepriced amount i.e. Rs 25,76,917.00. If quoted amount is less than the prepriced amount, same will be amended to pre-priced amount.Amount so adjusted will be deducted from quoted amount against Sch A Part-I i.e. Item No. 1.00 of BOQ. Quoted Amount of tender as a whole will remain unchanged due to this adjustment. 126 All as per BOQ serial item No 56.01 to 56.06 as mentioned here in before but for TENTH YEAR after completion of Ph-I.NOTE :-(a) The bidders shall ensure that the quoted amount for O&M is not less than minimum fair wages i.e. quoted amount is not less than the prepriced amount i.e. Rs 27,03,441.00. If quoted amount is less than the prepriced amount, same will be amended to pre-priced amount.Amount so adjusted will be deducted from quoted amount against Sch A Part-I i.e. Item No. 1.00 of BOQ. Quoted Amount of tender as a whole will remain unchanged due to this adjustment. 127 Comprehenisve maintenance of Solar Power Plant 0.8 MWpfor FIRST YEAR after expiry of DLP of Ph-I of the subject work with including periodical Check up andmaintenance as per OEM recommendation& connected accessories through Authorised Original Equipment Manufacturers Service Centre Engineersor through OEM Certified Agencies as approved by GE, complete all as specified and as directed. NOTE :-(a) Service engineer will carry scheduled preventative maintenance checks on SPV as per the standard check list of the OEM (b) Service engineer shall carry out checks on Solar Plant, as per the manufacturer’s check list and as directed by Engr-in Charge and would correct / recommend / suggest improvement in operation and performance. (c) Service Engineer during the visit will report on the performance or any other abnormality and inform parts requirement, shall also submit the report on work done and recommendations as well as spare parts offers to the concerned authority for arrangement.(d)Cost of equipment and spare parts which is not covered in warranty and DLP shall be measured in PC Sum andcost of item priced upto ₹500.00 shall be deemed to be included in the comprehenisve maintenance quoted cost. Repairs of minor components any other major components are also in the scope and cost of labour for minor / major components is deemed to be included in the quoted rate for this item.(e) Cost of gaskets, metal/rubber washer, CI washer special cement and small nuts/bolts and screws required for repair shall be deemed to be included in the unit rated quoted by the contractor. 128 Comprehenisve maintenance of Solar Power Plant 0.8 MWpfor SECOND YEAR after DLPof Ph-I of the subject work with including periodical Check up andmaintenance as per OEM recommendation& connected accessories through Authorised Original Equipment Manufacturers Service Centre Engineersor through OEM Certified Agencies as approved by GE, complete all as specified and as directed. NOTE :-(a) Service engineer will carry scheduled preventative maintenance checks on SPV as per the standard check list of the OEM (b) Service engineer shall carry out checks on Solar Plant, as per the manufacturer’s check list and as directed by Engr-in Charge and would correct / recommend / suggest improvement in operation and performance. (c) Service Engineer during the visit will report on the performance or any other abnormality and inform parts requirement, shall also submit the report on work done and recommendations as well as spare parts offers to the concerned authority for arrangement.(d)Cost of equipment and spare parts which is not covered in warranty and DLP shall be measured in PC Sum and cost up to Rs. 500.00 shall be deemed to be included in the comprehenisve maintenance quoted costrepairs of minor components any other major components are also in the scope of Annual Maintenance Contract.(e) Cost of gaskets, metal/rubber washer, CI washer special cement and small nuts/bolts and screws required for repair shall be deemed to be included in the unit rated quoted by the contractor. 129 Comprehenisve maintenance ofSolar Power Plant 0.8 MWpfor THIRD YEAR after DLPof Ph-I of the subject work with including periodical Check up andmaintenance as per OEM recommendation& connected accessories through Authorised Original Equipment Manufacturers Service Centre Engineersor through OEM Certified Agencies as approved by GE, complete all as specified and as directed. NOTE :-(a) Service engineer will carry scheduled preventative maintenance checks on SPV as per the standard check list of the OEM (b) Service engineer shall carry out checks on Solar Plant, as per the manufacturer’s check list and as directed by Engr-in Charge and would correct / recommend / suggest improvement in operation and performance. (c) Service Engineer during the visit will report on the performance or any other abnormality and inform parts requirement, shall also submit the report on work done and recommendations as well as spare parts offers to the concerned authority for arrangement.(d)Cost of equipment and spare parts which is not covered in warranty and DLP shall be measured in PC Sum and cost up to Rs. 500.00 shall be deemed to be included in the comprehenisve maintenance quoted cost repairs of minor components any other major components are also in the scope of Annual Maintenance Contract.(e) Cost of gaskets, metal/rubber washer, CI washer special cement and small nuts/bolts and screws required for repair shall be deemed to be included in the unit rated quoted by the contractor. 130 Comprehenisve maintenance ofSolar Power Plant 0.8 MWpfor FORTH YEAR after DLP of Ph-I of the subject work with including periodical Check up andmaintenance as per OEM recommendation& connected accessories through Authorised Original Equipment Manufacturers Service Centre Engineersor through OEM Certified Agencies as approved by GE, complete all as specified and as directed. NOTE :-(a) Service engineer will carry scheduled preventative maintenance checks on SPV as per the standard check list of the OEM (b) Service engineer shall carry out checks on Solar Plant, as per the manufacturer’s check list and as directed by Engr-in Charge and would correct / recommend / suggest improvement in operation and performance. (c) Service Engineer during the visit will report on the performance or any other abnormality and inform parts requirement, shall also submit the report on work done and recommendations as well as spare parts offers to the concerned authority for arrangement.(d)Cost of equipment and spare parts which is not covered in warranty and DLP shall be measured in PC Sum and cost up to Rs. 500.00 shall be deemed to be included in the comprehenisve maintenance quoted cost repairs of minor components any other major components are also in the scope of Annual Maintenance Contract.(e) Cost of gaskets, metal/rubber washer, CI washer special cement and small nuts/bolts and screws required for repair shall be deemed to be included in the unit rated quoted by the contractor. 131 Comprehenisve maintenance of Solar Power Plant 0.8 MWpfor FIFTH YEAR after DLPof Ph-I of the subject work with including periodical Check up andmaintenance as per OEM recommendation& connected accessories through Authorised Original Equipment Manufacturers Service Centre Engineersor through OEM Certified Agencies as approved by GE, complete all as specified and as directed. NOTE :-(a) Service engineer will carry scheduled preventative maintenance checks on SPV as per the standard check list of the OEM. (b) Service engineer shall carry out checks on Solar Plant, as per the manufacturer’s check list and as directed by Engr-in Charge and would correct / recommend / suggest improvement in operation and performance. (c) Service Engineer during the visit will report on the performance or any other abnormality and inform parts requirement, shall also submit the report on work done and recommendations as well as spare parts offers to the concerned authority for arrangement.(d) Cost of equipment and spare parts which is not covered in warranty and DLP shall be measured in PC Sum and cost up to Rs. 500.00 shall be deemed to be included in the comprehenisve maintenance quoted cost repairs of minor components any other major components are also in the scope of Annual Maintenance Contract.(e) Cost of gaskets, metal/rubber washer, CI washer special cement and small nuts/bolts and screws required for repair shall be deemed to be included in the unit rated quoted by the contractor. 132 Prime Cost Sum. The prime cost to be used as directed by the Accepting Officer vide Condition 1 (v) and 5 of IAFW-2249 (General Condition of Contracts) forming part of the tender documents.(a) Provide a prime cost of Rs.3,00,000.00 forsupply only of spare parts required for comprehensive maintenance after expiry of DLP of Phase-I, through a BOO convened by the CWE. The spares shall procured directly from the OEMs or their aurhorised distributor/dealer as approved by GE.(b) Bidders/Contractors quoted amount shall be inclusive of his overhead and profit and including all taxes and insert amount to cover all. The Bidders/Contractors is to quote lump sum amount under Column 6 covering all the aspects mentioned here in before, representing (%) percentage under Column 9, Above/Below (+ or - denomination) the Prime Cost Sum inserted by MES under Column 5. However, the quoted amount under Column 6 shall not exceed 15% (Fifteen Percentage) of Prime Cost Sum inserted by MES under Column 5. In case, the Bidders/Contractors quoted amount is in excess of 15% of the estimated amount, the same shall be restricted to 15% (Fifteen Percentage) and the amount quoted shall be corrected accordingly to work out the contract sum. Item Continued as 70.01 133 NOTE:-Prime Cost Sum shall be governed in terms of condition 1 (v) and 5 of IAFW-2249 (General Condition of Contract) and to be regularized through Deviation Order. The following procedure shall be adopted to execute the Prime Cost Sum :-(a) Step –I Service Engineer of OEM along with site executive shall visit every month for Preventive and corrective maintenance on all the Solar Power Plant as specified in BOQ herein before, and undertake routine comprehensive maintenance and identify the list of damage / defective spare parts in Solar Power Plant. Service Engineer have to submit report to concerned Engr-in Charge and BOO before undertaking replacement/ repairs, except in case of emergency.(b) Step –II Subsequently BOO will verify the same and submit the finding to the CWE after assembly of board in terms of CA Provision for concurrence.(c) Step –III After concurrence of BOO, the Engr-in-Charge will direct the contractor and the service provider to replace the unserviceable spare parts.(d) Step –IV Serviceability certificate of Solar Power Plant duly signed by the Service Engineer, BOO findings, GST enabled purchase voucher for the replaced spare parts alongwith draft DO details shall be submitted to the GE for placing of DO’s. The advance on account shall be accompanied alongwith the said DO’s for payment.
Contract Date: Mar 17, 2026 Contract Value : 6.86 Crore
Statutory Bodies & Commissions/Committees No of Bidders 6
West Bengal View Result →
17.
Housing Urban and Rular Development #9468312 Technical Bid
Tender For Providing Rates For Supply/Fixing Of Various Items As Per Bill Of Quantity For Meerut Mandal - The Makrana First Class Marble work for cladding will use 40mm thick slabs of premium Makrana marble, known for its uniform shade, minimal veining, and absence of surface defects. The backing for this marble cladding will be filled with a 12mm thick layer of cement mortar, mixed in a ratio of 1:3 (1 part cement to 3 parts coarse sand). The marble will be secured to the backing using stainless steel cramps or any other approved fixing system, which will be paid for separately. For joint treatment, pointing will be done using white cement mortar mixed with marble dust in a ratio of 1:2 (1 part white cement to 2 parts marble dust), with an admixture of pigment to match the marble’s shade, ensuring uniformity in appearance. After installation, the marble surface will undergo mirror polishing using mechanical equipment to achieve a high-gloss, scratch-free finish. 2 Classic decor POLE LIGHTS with customise bracket Supply ,Installation ,Testing And Commissining OfHybrid Decorative Pole Dragon-H Pole iwth height of 7-9M With CastedAluminium Base And Ripped Gi Pole PipeWith Decorative Post Top Lantern Concord 1270Mm Long With Polycarbonate Diffuser In 60W Led Having Lumn Output Not Less Than 110Lmns/Watt With 10Kva Surge Prtector Designed As Per Architect In-Charge( Make- Valmont-/-Havells/Neri/Juvaas/Orient/ Thor) 3 3-Dimensional Statue Ornamentation Work : supply, fabrication, transportation, hoisting, and installation of high-quality 3-Dimensional marble statues across various elements at all levels. The stone used must be free from cracks, lines, stains, and exhibit uniform shading throughout. It shall be fine-grained, with a reddish or buff color (locally sourced). The work is to be executed in strict accordance with the attached drawings, incorporating processes such as manual or machine carving, ornamental detailing, traditional motifs, figure work (of any type and size), CNC cutting, and molding. All carving and molding shall be of the highest quality. The installation of the stonework must be precise, ensuring that all elements are aligned, leveled, and plumb, and fixed using brass clamps, pins (to be paid for separately), dowels, cement slurry with matching pigments, and epoxy adhesives of approved brands such as Akemi Germany, Ardex Endura, or MYK Laticrete, as specified and approved by the Architects 4 Supplying, fabricating, transporting, hoisting and fixing in position good quality of Ornamentalsandstone statue in various elements for all levels, inlcuding the cost of oranmental stone work and mouldings, carvings as required, the stone of varied thickness shall be used for stacking. Also includes the cost of structural load calculation and design with respect to the drawing recevied from architect in charge. Preferable tentative size 1.5MX1.5MX1.5 Mtentative Size as approved from architect in charge 5 2-dimensional Ornamentation Work :- Supplying, fabricating, transporting, hoisting, and fixing in position good quality marble for various elements at all levels. The stone shall be free from cracks, lines, stains, and shall have an even shade for each element. The stone shall be fine-grained and reddish or buff-colored (locally available). The work shall be carried out as per the attached drawings, involving different processes such as carving (manual or by machine), ornamental work, traditional work, figure work (any type, any size), CNC cutting, and molding. The carving and molding work shall be of very good quality. The stones are to be fixed in line, level, and plumb in all respects using brass clamps, pins (to be paid for separately), dowels, cement slurry with matching pigment, and Epoxy of Akemi Germany, Ardex Endura, MYK Laticrete, or other approved brands as required and as approved by the Architects. 6 Supply, Installation, Testing & Commissioning of 16mm X 16mm of 5 meters length RGBW Neon Flexible stripled light with Non- Integral driver embedded inside. The luminaire’s shall be made of Silicon extrusion with high-efficiency, high grade appearance, soft bend flexibility & Option of Top bend , the same shall be so designed with completely made in India luminaire.The luminaire shall have silicon glue between optical cover & LED chamber to ensure proper IP67 protection. Required external decoder. The LEDs shall have minimum CRI ≥80 (White Light). The luminaire shall have system wattage of 14 Watt/ meter. Fixture shall operating temperature range of 0°C to 45°C. The fixture shall have an Non integral driver with input voltage for 220-240 VAC, 50/60Hz. The luminaire shall have declared life of 50,000 burning hours The luminaire shall be compatible with DMX512 controller. The luminaire shall automatically addressable using hand-held addressing device. The luminaire shall be capable of 6-bit control of RED, Green, Blue & White (W=4000K) to produce 16.7million colours.Luminaire manufacturer must have In-house NABL accredited lab to conduct LM79. The successful bidder must submit the NABL accreditation certificate for Luminaire manufacturer along with technical bid. Bidder shall submit the following reports along with technical bid LM79 report of the family of luminaire issued by NABL accredited lab, LM80 issued by LED manufacturerBIS certificate for LED Luminaire.. Brand name shall be embossed / printed on each an every light fixtures. (Wipro/Trilux/Colour Kinetics) 7 POLE LIGHTS Supply ,Installation ,Testing And Commissining OfTwinkle Lites Make 3000Mm Long Hybrid Decorative Pole With CastedAluminium Base And Ripped Gi Pole PipeWith Decorative Post Top Lantern Concord 1270Mm Long With Polycarbonate Diffuser In 60W Led Having Lumn Output Not Less Than 110Lmns/Watt With 10Kva Surge Prtector Designed As Per Architect In-Charge( Make- Twinkle Lite-/-Havells/Neri/Juvaas/Orient/ Thor) 8 Supply, Installation, Testing & Commissioning of 196mm Dia X 158mm Height RGBW Circular Flood light with Non-integral driver & completely made in India luminaire. Luminaire must use Single LED of RGBW ChIPand not descrete individual LEDs of each colour for colour effect. The luminaire’s shall be made of Extruded aluminum housing powder coated in grey. The complete luminaire has IP66 & IK08 protection and it comprises of high purity integrated poly carbonate Lens.The LEDs shall have minimum CRI ≥80 (White LED) & shall have SDCM≤5. The luminaire shall have wattage 60W and shall deliver 3300 lumens. Beam angle of the Luminaire shall be 15 deg .Fixture shall operating temperature range of 0°C to 45°C. Input Voltage Range of 24V DC, Integrated DMX Decoder,No need to additional external decoder. The luminaire shall have declared life of 50,000 burning hours at L70. The luminaire shall be compatible with DMX controller. The luminaire shall automatically addressable using hand-held addressing device. The luminaire shall be capable of 8-bit control of RED, Green, Blue & White (W=4000K) to produce 16.7million colours. Luminaire and Driver must be made in India with same brand. Luminaire manufacturer must have In-house NABL accredited lab to conduct LM79. The successful bidder must submit the NABL accreditation certificate for Luminaire manufacturer along with technical bid. LM80 , RoHS compliance issued by LED luminaire manufacturer, BIS certificate for LED Luminaire. Brand name shall be embossed / engraded on each an every light fixtures. Luminaire and Driver should be Made in India. Luminare, Driver and controller should be with same make. (Wipro/Trilux/Colour Kinetics) 9 Supplying, fabricating, transporting, hoisting, and fixing in position high-quality modular size wire-cut bricks for various elements at all levels. The bricks shall be free from cracks, lines, stains, and even in shade for each element, ensuring uniformity. The bricks shall be fine-grained and of a reddish or buff color, sourced locally. The work shall be executed as per the attached drawings, incorporating various processes such as carving (manual or by machine), ornamental work, traditional work, figure work (of any type and size), CNC cutting, and molding. The carving and molding work shall be of excellent quality, finished with a water-repellent coating from an approved manufacturer, as required and as approved by the architects. 10 Supply, Installation, Testing & Commissioning of 1000 mm length X 80mm Width X 115mm Height RGBW Linear Wall Washer with Non-integral driver & completely made in India luminaire. Luminaire must use Double LED Array of RGBW Chip Double Array and not descrete individual LEDs of each colour for colour effect. The luminaire’s shall be made of Extruded aluminum housing powder coated in grey. The complete luminaire has IP66 & IK07 protection and it comprises of high purity integrated poly carbonate Lens.The LEDs shall have minimum CRI ≥80 (White LED) & shall have SDCM≤5. The luminaire shall have wattage 96W and shall deliver 3840 lumens. Beam angle of the Luminaire shall be Assy. deg .Fixture shall operating temperature range of 0°C to 45°C. Input Voltage Range of 24V DC, Integrated DMX Decoder,No need to additional external decoder. The luminaire shall have declared life of 50,000 burning hours at L70. The luminaire shall be compatible with DMX controller. The luminaire shall automatically addressable using hand-held addressing device. The luminaire shall be capable of 8-bit control of RED, Green, Blue & White (W=4000K) to produce 16.7million colours. Luminaire and Driver must be made in India with same brand. Luminaire manufacturer must have In-house NABL accredited lab to conduct LM79. The successful bidder must submit the NABL accreditation certificate for Luminaire manufacturer along with technical bid. LM80 , RoHS compliance issued by LED luminaire manufacturer, BIS certificate for LED Luminaire. Brand name shall be embossed / engraded on each an every light fixtures. Luminaire and Driver should be Made in India. Luminare, Driver and controller should be with same make.(Wipro/Trilux/Colour Kinetics) 11 Supplying, fabricating, transporting, hoisting, and fixing in position high-quality modular size wire-cut bricks for various elements at all levels. The bricks shall be free from cracks, lines, stains, and even in shade for each element, ensuring uniformity. The bricks shall be fine-grained and of a reddish or buff color, sourced locally. The work shall be executed as per the attached drawings, incorporating various processes such as carving (manual or by machine), ornamental work, traditional work, figure work (of any type and size), CNC cutting, and molding. The carving and molding work shall be of excellent quality, finished with a water-repellent coating from an approved manufacturer, as required and as approved by the architects. 12 Supplying, fabricating, transporting, hoisting and fixing in position good quality of Ornamental red sandstone Jharokha in various elements for all levels, inlcuding the cost of oranmental stone work and mouldings, carvings as required, the stone of varied thickness shall be used for stacking. Also includes the cost of structural load calculation and design with respect to the drawing recevied from architect in charge. Preferable tentative size 0.5MX0.3MX0.75Mtentative Size as approved from architect in charge 13 Supply, Installation, Testing & Commissioning of 196mm Dia X 158mm Height RGBW Circular Flood light with Non-integral driver & completely made in India luminaire. Luminaire must use Single LED of RGBW ChIPand not descrete individual LEDs of each colour for colour effect. The luminaire’s shall be made of Extruded aluminum housing powder coated in grey. The complete luminaire has IP66 & IK08 protection and it comprises of high purity integrated poly carbonate Lens.The LEDs shall have minimum CRI ≥80 (White LED) & shall have SDCM≤5. The luminaire shall have wattage 60W and shall deliver 3300 lumens. Beam angle of the Luminaire shall be 30deg .Fixture shall operating temperature range of 0°C to 45°C. Input Voltage Range of 24V DC, Integrated DMX Decoder,No need to additional external decoder. The luminaire shall have declared life of 50,000 burning hours at L70. The luminaire shall be compatible with DMX controller. The luminaire shall automatically addressable using hand-held addressing device. The luminaire shall be capable of 8-bit control of RED, Green, Blue & White (W=4000K) to produce 16.7million colours. Luminaire and Driver must be made in India with same brand. Luminaire manufacturer must have In-house NABL accredited lab to conduct LM79. The successful bidder must submit the NABL accreditation certificate for Luminaire manufacturer along with technical bid. LM80 , RoHS compliance issued by LED luminaire manufacturer, BIS certificate for LED Luminaire. Brand name shall be embossed / engraded on each an every light fixtures. Luminaire and Driver should be Made in India. Luminare, Driver and controller should be with same make.(Wipro/Trilux/Colour Kinetics) 14 Supply, Installation, Testing & Commissioning of 148mm Dia X 149mm Height RGBW Circular Flood light with Non-integral driver & completely made in India luminaire. Luminaire must use Single LED of RGBW ChIPand not descrete individual LEDs of each colour for colour effect. The luminaire’s shall be made of Extruded aluminum housing powder coated in grey. The complete luminaire has IP66 & IK08 protection and it comprises of high purity integrated poly carbonate Lens.The LEDs shall have minimum CRI ≥80 (White LED) & shall have SDCM≤5. The luminaire shall have wattage 36W and shall deliver1980 lumens. Beam angle of the Luminaire shall be 15 deg .Fixture shall operating temperature range of 0°C to 45°C. Input Voltage Range of 24V DC, Integrated DMX Decoder,No need to additional external decoder. The luminaire shall have declared life of 50,000 burning hours at L70. The luminaire shall be compatible with DMX controller. The luminaire shall automatically addressable using hand-held addressing device. The luminaire shall be capable of 8-bit control of RED, Green, Blue & White (W=4000K) to produce 16.7million colours. Luminaire and Driver must be made in India with same brand. Luminaire manufacturer must have In-house NABL accredited lab to conduct LM79. The successful bidder must submit the NABL accreditation certificate for Luminaire manufacturer along with technical bid. LM80 , RoHS compliance issued by LED luminaire manufacturer, BIS certificate for LED Luminaire. Brand name shall be embossed / engraded on each an every light fixtures. Luminaire and Driver should be Made in India. Luminare, Driver and controller should be with same make.(Wipro/Trilux/Colour Kinetics) 15 Supplying, fabricating, transporting, hoisting and fixing in position good quality of Ornamentalsandstone statue in various elements for all levels, inlcuding the cost of oranmental stone work and mouldings, carvings as required, the stone of varied thickness shall be used for stacking. Also includes the cost of structural load calculation and design with respect to the drawing recevied from architect in charge. Preferable tentative size 1.2MX0.6MX0.6 Mtentative Size as approved from architect in charge 16 Providing and fixing archeton terracotta cladding of U-Value 0.8 & R value of 1.25 and dimension 304*594*16 mm with modules of 300*600 with Q3** resistance to impacts (classification as per French standards) with wind resistance to positive/ negative pressure 6500 / 4500 Pa, weight of27.13 kg per m2 which conform to standard NF EN 539-2, water absorption to be between 3% - 5% conforming to EN ISO 10545-3 § 5.1.1, bending strength not to exceed 1400 Newton conforming to EN ISO 10545-4. Installation of terracotta panels to be done by securing to the vertical T-shaped aluminium profile using the fixing clips fastened with 2 self-tapping stainless steel screws. Vertical aluminium T-shaped profiles are to be pre-punched hole with vertical spacing of 25mm. The terracotta tile is to be well-supported on four points by the clips and on its two smaller sides by the rubber gasket so as to have a very good wind load resistance of more than 6500 PA positive wind load pressure and a negative wind load pressure of 4500 PA and flexural strength of 135 da N. The total thickness cladding system is not to be more than 110 mm.The quantity of products per sq.m are to be 5.56 tiles, with quantity of profiles per main course sq.m to be 1.67 lm/m2, with quantity of clips to be 11.11 nos. per sq.m . Scaffolding and electricity for fixing to be provided by GC Make -Archeton 17 LEDmodules are engineered accordingly to the existing regulations of LumenMaintenance (LM80) and Technical Memorandum (TM21), Lifespan of the luminaire > 60,000 hours at 40°C. Operating ambient temperature range is from -15°C to +50°C. Driver efficiency >85%, power factor >0.9, THD <10%, Surgeprotection 6KV. Product as per KLiTE KL4636. The manufacturer should have inhouse manufacturing facility and inhouse goniophotometer to check the photometry of the LuminaireSITC of 15w integrated Solar All in one suitable at height of 5mtr mounting arrangement. pole with minimum 1800 lumen , luminous flux with min.>150lm/w luminous efficacy having power of PV module (Wp) 40, Panel Type Mono Crystalline, Panel Dimensions not more than (mm) 655 (L) x 400 (W) x42 (H), Battery Capacity max. 15 (Ah), Battery Rated Voltage 12.8(V), Battery type LiFePO4, having BMS protection Battery Management System ,having min. Battery Back up to 2days (24 hours) (Autonomy mode),MPPT charge controller type, Efficacy>90%, having facility of Charging Indicator (Green blinking),Low Battery Indicator (Red blinking),Error Indicator (Both blinking),For the better battery life having Over Charge Protection, Deep Discharge Protection, Battery reverse polarity protection ,Load Short circuit protection, Load Open circuit protection, Reverse polarity protection for Panel, Over temperature protection. Motion sensor detection facility with Long Distance Detection 12m.CCT-4000-6000k, Make-Valmont,Panasonic, Philips or equivalent 18 Supply of exterior rated Architectural RGBW Linear LED Wall Washer luminaire; suitable for facade lighting with extruded aluminium housing, powder-coated finish, Clear toughened glass of 4mm thickness and die casted end caps, Total System wattage not exceeding 40W with system lumen output should be more than 1500 lm with all LEDs on. Luminaire shall be capable of producing dynamic color changing light with 16 million colors as the light fixture should be programmable using 8 bit control DMX512 protocol / Ethernet based control. Luminaire should be complete with dedicated Lens made up of UL/VDE approved PC for each LED, offering beam angle of different types such as narrow, medium, wide or elliptical as per the site requirement. Fixture should have Height 125.5 mm ± 5% including surface mount basewidth 64 mm ± 5% , length 1200 mm ± 5% with constant locking hinges for simple position control from various angles without special tools. DMX enabler circuit should be inside the Luminaire only. The rated voltage of the Luminaire should be 230Vac, Luminaire shall be offered with a BIS Approved Potted Driver of IP 66/67 rating made of extruded aluminium to make it more thermal efficient, Led Driver should have Operating input voltage range: 90-305VAC, PF > 0.90 and must have safety operation range form 90V - 176Vac. Life time of LED driver should be > 80,000hours and MTBF of LED driver should be ≥ 2,00,000 hrs, Led driver must have SELV output and Case temperature i.e. Tc > 90°C. Fixture shall be suitable to operate at an ambient temperature range of -30°C to 50°C and complete luminaire shall be IP66 and IK07 rated. LED Life time shall be at least L70B50 @ 70000 burning hours at 50°C. LED should be with ceramic package of make Nichea, Osram, Cree, Lumiled only.The product should be BIS approved with R number mentioned on product label. To be supported with Product test reports - LM79, BIS Report and LEDs Test Reports. Luminaire shall be conforming to BIS i.e. IS 10322 (Part 5/Sec 5) and shall be complete with all necessary accessories required for proper working of fixture including weather proof connection cables, water proof connectors etc. as required. 19 Bollards Supply And Fixing Of Twinkle Lites Make Tigris 800Mm Long Made Out Of Extruded Aluminium Profile With Cast Alumn Base With 18W Led. (Make- Twinkle Lite-Equvalent In :-Havells/Neri/Juvaas/Orient/ Thor) 20 Supply, Installation, Testing and commissioning of DMX Master Controller, with completely made in India product. A stand alone interface for installation in electrical DIN Cabinets with Din rails, which can control from 512 to 1024 and can go up to 2048 channels on 1, 2 or 4 DMX universes. A robust Stand Alone mode and a wide range of trigger possibilities (RS232, Contacts, Clock, NODE x4 ports, Master/slave), USB-C Networks Ethernet, Internet, WIFI compatible when connected to a router Multiple Zone 10 Zone, play 10 scene/sequence per time in Stand Alone ,Memory of Micro SD Card ( max. 256 GB ) and 8Mb Internal memory . Art-Net and sACN from SD card, including triggers (2x512). A master / Save Synchro (32 max wired / 128 max Ethernet) that Commands from the Contacts (speed, scene, dimmer, zone). Default start scene, Scene priority, Cross Fade time between scenes , Automatic Scene Recovery if the power is cut off and 16-bit and fine channel management. Triggers options of RS232 In/Out (16 characters max for RS232 triggers, commands or orders) and UDP / Ethernet triggers and commands (from SDK). Software Requirements with System Compatibility of Windows, Mac, iOS. Flexible, adaptable mounting options ,Should be provided with light show authoring software, Direct line voltage power supports 100—240VAC,Minimum five configurable effects, Using light show authoring software to select from standard five effects, adjust effect settings such as color, speed, and brightness. IP20. Addressing & Programming inclusive and with Five Year Warranty. Brand name shall be embossed on each and every lighting fixtures.(Wipro/Trilux/Colour Kinetics) 21 Supply of 4 Meter height Carley Square 40W LED in Extruded aluminium bottom pipe (grade 6063 with test certificate) Sq. 150 x 3mm thickness, extruded aluminium stem with inner ribbed Sq.30 x 2mm thickness, extruded aluminium top pipe with inner ribbed with Light Distribution 360°. Pre treated with silicone gaskets. PDC aluminium service door 330mm height x 75mm width at 335mm height above the base plate shall be provided with the company logo embossed on the bottom of the door and safety rope. The control gear tray is prewired with 2.5 Sq.mm cable, 6A MCB and 32A terminal connectors for loop-in / loop-out arrangement. For better lighting performance there is Optical grade clear toughened glass diffuser of 4mm thickness with controlled downward light emission. Lamp fixed is position. This luminaire contains built-in LED modules. LED modules are engineered accordingly to the existing regulations of Lumen Maintenance (LM80) and Technical Memorandum (TM21), Lifespan of the luminaire > 60,000 hours at 40°C. Operating ambient temperature range is from -15°C to +50°C. Driver efficiency >87%, power factor >0.95, IP65, THD <10%, Surge protection 5KV. LED Colour Temperature 3000K, 230-240Vac, CRI >80, MacAdam step> 3, Mechanical resistance IK08. MS mounting plate Sq. 250 x 12mm thick steel of grade E250 to IS 2062:2011 with 4 elongated holes 38 x 19 to suit M16 bolts at CC180. This mounting steel plate along with foundation bolts of suitable size to be used for ensuring firm grouting into the specially designed foundation pole. Hot dip galvanised foundation bolt. The pole should undergone Pure polyester powder coated process, Mild shot blasting. The product should be BIS and CE Certified. Make as per Klite KL-4663/Unilamp/Ligman. 22 Supply, Installation, Testing and commissioning of DMX Decoder completely made in India product .Input Power DC 12V -24V input which Outputs 6A/Channels. 100-240V, 24VDC plug-in power adaptor .The number of devices controlled from 001-512 via DIP Switch. Connection of DMX (3 pin, 3.5mm pitch screw terminal). Channel bondin capable up to 10A. 8 pin terminal connector current LED connection. Compact PCB or chassis mounted.All six output ports should have an independent output driver and ELV transformer to boost the DMX signal. 1: 6 Way DMX Splitter/Booster ,Optically isolated DMX Input/Outputs, Individual coil transformer for each output , Surface/Rack/Floor/Celling mountable with provide mounting accessories ,Refined and filtered data , Cable 3 core 0.75sq.mm .Five Year Warrantyof DMX Signal Splitter+Amplifier - One DMX512 signal Input to six DMX512 outputs, Designed to amplify, distribute and isolate DMX signals in short-runs and localised splitting scenarios. Protection of short circuit, Reverse Polarity, Over Temprature, Over Voltage and Over Current. Photo-electric isolation between Input and Output terminals as well as between output terminals among channels. Compensates for any intereference from external sources like AC lines, Electrical equipment operating close to DMX transmission lines.Compact DIN rail enclosure enables easy installation inside most enclosures. 23 Supply, installation, testing & commissioning of DMX Controller for the system including all other accessories required for the running of the system Controller should have Input Power 5-5.5V DC 0.6A and Output Protocol DMX512 with 4 universe,2 universe should work in Stand Alone Mode and 2 universe should work in live mode with laptop/ tablet / computer. The universeshould be expandable from 2 to 4 DMX512 universes.It should be compatible for Programmability with PC, Mac, Tablet, Smartphone by using USB & Ethernet .Dmx controller should have network controllabilityfeature to control the scene remotely through LAN and triggered via UDP packets on port 2430.Its must have Connections Type C USB, XLR3, Ethernet, battery. There should be provision for Memory microSD card. Device should haveIntuitive backlit keyboard with 10 presets and also have provision of kepad on devicefor changing scene manually from device. Device should be capable to work on Extended triggering possibilities (TCA) & also have Smart Upgrade Technology (SUT). It is an IP 20 unit and has an Operating Temperature of 0°C to 50°C. weight should not be more than 120g. OS Requirements for the controller is Mac OS X 10.8-10.12, Windows 7/8/10. Standards should be EC, EMC, ROHS. The controller should have a variety of features including 2048 DMX channels, clock/calendar, iPhone/iPad/Android remote control, Ethernet facilities, dry contact port triggering and multi-zone SD card memory. Network synchronization of one area across hundreds of universes with the possibility of 99 scenes across 5 areas with auto clock triggering for sunrise and sunset and as per the festivals for specific occasions. Device should be equipped with meta; clamp to mount on wall. All Dynamic LED lighting fixtures & controllers shall be of same make to avoid integration, synchronization, and maintenance issues in future. To be provided with IP 66 enclosure if installed in external environment & shall be provided with all necessary accessories required for proper working of fixture including weather proof connection cables, water proof connectors etc. as required. 24 Supply of Isolated, constant Voltage type240 W LED Driver enclosurein Extruded Aluminium metal enclosure . Driver shall be made in India compatible for RGBW luminaires with silicone potted and IP 66 Protected of same make as luminaire. Output voltage of the driver 24Vdc. Driver efficiency should be greater than 85% at full load, THD < 10%, PF > 0.95 with Under and Over Voltage Cutoff Protection and 440V withstand for 8 hours minimum & sould have large operating input voltage range of 150V to 270V (nominal rated voltage – 240V) with 5KV internal surge protection. LED driver shall have inbuilt output short circuit, over voltage protection, Thermal Shutdown protection. 25 Constructing brick masonary open surface drain with bricks of class designation 75 in cement mortar 1:4 (1 cement : 4 fine sand) including earth excavation, 10cm thick bed concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size) and 25mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 12.5mm nominal size) for filling haunches including 12mm cement plaster 1:4 (1 cement : 4 coarse sand ) with a floating coat of neat cement inside the drain, its top and exposed side including disposal of surplus earth complete as per standard design:Drain 300 wide average.Depth 45 cm with R.C.C. slab 26 Providing machine made Wire Cut Bricks where edges are sharp and borders are straight and Size of8.5x 4x3having Smooth surface finish with Compression Strength should be less than 105 kg/sq cm and Water absorption should not exceed 20%. Thickness of 230mm wall 27 Supplying, designing, fabricating, transporting, hoisting and fixing in position mural works in good quality of 70 mm Red sandstone, and 18mm marble insertion and 6-10mm powder coated MS sheet in various elements for all levels. Stone shall be free from cracks, lines stains and even in shade for each element. The stone shall be fine grained and reddish or buff-colored (locally available). The work shall be carried out as per attached drawings with different process of i.e carving (manual/ by machine), ornamental work, traditional work, figure work (any type, any size), CNC cutting, moulding, etching, buffing and polishing. The carving and molding work shall be of very good quality. The work to be fixed in line, level and plumb in all respect with the use of brass clamps, pins, (to be paid separetely) dowels, cement slurry with matching pigment and Epoxy of Akemi Germany, Ardex Endura, MYK laticrete or approved make as required and as approved by the Architect in charge. 28 Supply, Installation, testing & commissioning of Vertical in line pumping setcomplete. The rate shall include the cost of electrical panel and piping work completeDomestic Water Supply pumps :Capacity/Flow Rate - 12.5 m3/hrHead- 45 mLocation-1 set in UGT (1 set = 2nos(1W+1S)) 29 Supply, Installation, testing & commissioning of Vertical in line pumping setcomplete. The rate shall include the cost of electrical panel and piping work completeDomestic Water Supply pumps :Capacity/Flow Rate - 12.5 m3/hrHead- 45 mLocation-1 set in UGT (1 set = 2nos(1W+1S)) 30 Providing and fixing exposed brick flooring with modular common burnt clay bricks, machine made bricks: Indian chamfered and classic belgian rough bricks where edges are sharp and borders are straight and Size of200X100X40 for belgian rough and 230X110X25 for Indian chamfered having Smooth surface finish with Compression Strength should be less than 105 kg/sq cm and Water absorption should not exceed 20%on a bed of 12 mm cement mortar, to be laid in pattern as per drawing approved from Architect in charge including filling the joints with same mortar (make Prayag Clay Products or equivalent) 31 Providing and laying 80 mm thick machine cutcement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge. 32 Supply and Fixing of KL-4098 Inground Luminare of 8W LED Asymmetrical (DIA.116 X153)MM Supply of 3000K/4000K/5700K In-ground 8W asymmetrical luminaire made up of die-casting with Ø116 stainless steel 316 gradefront ring with silicone black gasket and toughened clear glass diffuser. With Electronic Driver, The luminous flux of the luminaire is upto 550 lm for 3000K BA- 35°/45° (Asy). The ingress protection is IP67 and impact resistance of IK08. The luminaire is integrated with high power NICHIA LED with CRI≥80, SDCM≤3, L70/ B10 @ 60000 Hrs at L70B10. The integral constant current driver comes with the power factor greater than or equal to 0.9, total harmonic distortion less than 15% with operating efficiency greater than 80% and a surge protection of 3KV. The driver input voltage 240Vac at 50-60Hz, operating voltage of 100- 277Vac and operating temperature of -20˚ ~ +40˚C with CE confirmed BIS approved. There may be changes in fixture selection and quantity as per architect intent Make: K-Lite KL-4098, Unilamp/ Ligman 33 Providing machine made Wire Cut Bricks where edges are sharp and borders are straight and Size of8.5x 4x3having Smooth surface finish with Compression Strength should be less than 105 kg/sq cm and Water absorption should not exceed 20%. Thickness of 230mm wall Ground Floor 34 Supply of Isolated, constant Voltage type150 W LED Driver enclosurein Extruded Aluminium metal enclosure . Driver shall be made in India compatible for RGBW luminaires with silicone potted and IP 66 Protected of same make as luminaire. Output voltage of the driver 24Vdc. Driver efficiency should be greater than 85% at full load, THD < 10%, PF > 0.95 with Under and Over Voltage Cutoff Protection and 440V withstand for 8 hours minimum & sould have large operating input voltage range of 150V to 270V (nominal rated voltage – 240V) with 5KV internal surge protection. LED driver shall have inbuilt output short circuit, over voltage protection, Thermal Shutdown protection. 35 Supply, installation, testing and Commissioning of 5Core 5C DMX cable/Patch cord Patch Endcap 1m 36 Supply of exterior rated Architectural LED RGB flood lighting luminaire; suitable for facade lighting with Die-cast aluminium housing, powder-coated finish, Clear toughened glass of 4mm thickness, Total System wattage not exceeding 40W withsystem lumen output should be more than 2000 lm with all LEDs on. Luminaire shall be capable of producing dynamic color changing lightwith 16 million colors as the light fixture should be programmable using 8 bit control DMX512 protocol / Ethernet based control. Luminaire should be complete with dedicated Lens made up of UL/VDE approved PC for each LED, offering beam angle of different types such as narrow, medium, wide or elliptical as per the site requirement. Fixture should have Height 66 mm±1% including surface mount base , Length of282 mm±1% and Width of 274mm±1% with constant locking hinges for simple position control from various angles without special tools. Fixture shall be suitable to operate at an ambient temperature range of -20°C to 50°C and complete luminaire shall be IP66 and IK07 rated. LED Life time shall be at least L70B50 @ 70000 burning hours at 50°C. LED should be with ceramic package of make Nichea, Osram, Cree, Lumiled only. DMX enabler circuit should be inside the Luminaire only.. Luminaire shall be complete with integrated BIS IP 66/67 potted driver and capable of operating at line voltage from 90-305 Vac, 50Hz with power factor > 0.9. The product should be BIS approved with R number mentioned on product label. To be supported with Product test reports - LM79, BIS Report and LEDs Test Reports. Luminaire shall be conforming to BIS i.e. IS 10322 (Part 5/Sec 5) and shall be complete with all necessary accessories required for proper working of fixture including weather proof connection cables, water proof connectors etc. as required. 37 Providing and fixing of outdoor fixed stone bollard of size 300X1000m, finish: sanded with a polished effect inlcuding rate ofengraving and illustrations as per architect incharge 38 Supply, Installation, testing and commissioining of TruAudio AS-1 AcoustiScape 4.5Outdoor Landscape Speaker Make: Bose/ L-Acoustic/ Powersoft 39 Planning, Designing, Programming of all the light fixtures with integration into controller and making multiple programming in total of 5 different occasion. Synchronizing all fixtures into one. 40 SITC of 15w integrated Solar All in one suitable at height of 5mtr mounting arrangement. pole with minimum 2250 lumen , luminous flux with min.>150lm/w luminous efficacy having power of PV module (Wp) 40, Panel Type Mono Crystalline, Panel Dimensions not more than (mm) 775 (L) x 340 (W) x 60 (H), Battery Capacity max. 18 (Ah), Battery Rated Voltage 12.8(V), Battery type LiFePO4, having BMS protection Battery Management System ,having min. Battery Back up to 2days (24 hours) (Autonomy mode),MPPT charge controller type, Efficacy>90%, having facility of Charging Indicator (Green blinking),Low Battery Indicator (Red blinking),Error Indicator (Both blinking),For the better battery life having Over Charge Protection, Deep Discharge Protection, Battery reverse polarity protection ,Load Short circuit protection, Load Open circuit protection, Reverse polarity protection for Panel, Over temperature protection. Motion sensor detection facility with Long Distance Detection 12m.CCT-5500-6000k, Make-Panasonic, Philips or equivalent 41 Supply, Installation, Testing and commissioning of DMX Splitter, Booster 343 mmHeight X 123mm Width X 46 mm Depth with completely made in India product .Input Power DC 12-24V input, 100-240V, 24VDC plug-in power adaptor included Power Consumption 4.5W max and of MS/ Aluminium Housing. Power Consumption of 4.5 Approx and Weight of 1.5Kg .The output terminals should be optically isolated from the input and share a common ground reference. All six output ports should have an independent output driver and ELV transformer to boost the DMX signal. 1: 6 Way DMX Splitter/Booster ,Optically isolated DMX Input/Outputs, Individual coil transformer for each output , Surface/Rack/Floor/Celling mountable with provide mounting accessories ,Refined and filtered data , Cable 3 core 0.75sq.mm .Five Year Warrantyof DMX Signal Splitter+Amplifier - One DMX512 signal Input to six DMX512 outputs, Designed to amplify, distribute and isolate DMX signals in short-runs and localised splitting scenarios. Photo-electric isolation between Input and Output terminals as well as between output terminals among channels. Compensates for any intereference from external sources like AC lines, Electrical equipment operating close to DMX transmission lines.Compact DIN rail enclosure enables easy installation inside most enclosures. (Wipro/Trilux/Colour Kinetics) 42 Supply& Erracetionof factory fabricated & wired metal clad dust and vermin proof floor mounting, M.S. Channel Base with bottom and top cable entreise Electrical control panel with TPN MCCBs (Four Pole 36 KA with thermal magnatic release) Switches Complete and instrument chamber etc.complete in all respects. The instrument chamber shall be separate and shall comprise of flush type digital metering system for phase to phase voltage and single phase voltage, current and other parameters (KVA,P.F,KW etc) in each phase with touch type selector L.T. Switch Panel Board :switches for different readings, instrument fuses, current transformer etc. The panel board shall have suitable capacity electrolytic alumininum busbars as per IS8623 or above insulated with heat shrink sleeving and mounted on non gyroscopic supports such as CMC/BMC support with deteachable side covers and shall be suitable for extension on the sides. The MCCBs shall be complete with suitable cable end boxes, compression glands and indicating lamp on incoming etc. The Job includes the grounting of the board as per directions of Engineer-in charge. All out goings of 100 Amp and above shall have an Ammeter. The panel board shall be fabricated with CRCA sheet with a minimum thickness of 1.6mm/2mm.Cubicletype switchboard shall be of cat A & B Only. CAT. B Cubicle TypeLighting Panel :Incoming -100 Amp MCCB - 1 No.Outgoing - 40 Amp DP MCCB - 4 No. (for d.b. )32 Amp 4P MCCB - 2 No. (for Spare)(Complete as per requirment directed by Project Manager.)Armoured Cables (Cable/Gland/Lug) : 43 FREE STANDING WALL CLADDING 44 Providing and laying 80 mm thick machine cutcement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge. 45 Supplying, designing, fabricating, transporting, hoisting and fixing in position mural works in good quality of 70 mm Red sandstone, and 18mm marble insertion and 6-10mm powder coated MS sheet in various elements for all levels. Stone shall be free from cracks, lines stains and even in shade for each element. The stone shall be fine grained and reddish or buff-colored (locally available). The work shall be carried out as per attached drawings with different process of i.e carving (manual/ by machine), ornamental work, traditional work, figure work (any type, any size), CNC cutting, moulding, etching, buffing and polishing. The carving and molding work shall be of very good quality. The work to be fixed in line, level and plumb in all respect with the use of brass clamps, pins, (to be paid separetely) dowels, cement slurry with matching pigment and Epoxy of Akemi Germany, Ardex Endura, MYK laticrete or approved make as required and as approved by the Architect in charge. 46 Supply, Installation, Testing and Commissioning of Feeder Panel - 5 KVA 3 Phase along with01 No. UPS to provide safety / good quality power supply to DMX Controller. 47 Supply and Installation of Circular pendant Luminaire 36W with IP65 and mechanical resistance IK07 Luminaire made of extruded aluminium alloy (grade 6063) of high corrosion resistance with translucent Diffuser Material of Clear PMMA extruded lens. Luminaire should be with Standard suspension kit of 1M. Protection class IP44. The driver should be inbuilt with the luminaire. Luminaire should be Powder coated white / grey. Available colour temperature 2700K / 3000K / 4000K / 5700K, Beam Angle should be 120° for uniform lighting effect. Colour rendering index (CRI)>80. SDCM ≤ 3 MacAdam. K-Lite LED module with expected service life of at least 60,000 operating hours. Make should be as per KL-3232/ Ligman/ Unilamp. Prewired with LED driver and suitable for operating on 240V, 50Hz single phase ac supply. Driver efficiency >85%, Power factor >0.95, THD <10%, Surge protection upto 3KV. Luminaire dimension : Ø900mm dia and 25mm height. CE & BIS Certified. 48 Supply of linear 3000K/4000K/5700K In-Ground Grazer 24Vdc CRI >90 MacAdam step 3 Input power : 12WLight Distribution should be Symmetrical Electronic driver ON/OFF (External driver) CE and BIS Approved. LUMINAIRE TYPE: Facade encapsulated3000K/4000K/5700K In-Ground Graze with IP67. MATERIAL CHARACTERISTICS should be High grade aluminium housing (grade 6063 with test certificate) with End cap, SS fasteners & Clip, Mechanical resistance IK07. LIGHTING PERFORMANCE:: Polyurethane Encapsulation clear diffuser. This luminaire contains built-in LED modules. LED modules are engineered accordingly to the existing regulations of Lumen Maintenance (LM80) and Technical Memorandum(TM21), Lifespan of the luminaire > 60,000 hours at 40°C. Operating ambient temperature range is from -15°C to +50°C. Driver efficiency >85%, Surge protection 3KV. Including required accessories There may be changes in fixture selection and quantity as per architect intent Make Klite KL-3277,Unilamp/Ligman 49 Supply and fixing of TG RO43 BETA, powder coated Tree guard as per design approved by Architect in charge with the following specifications:The unit is in powder form, packed in a 5Kg drum for secure handling and transportation. The product features a cylindrical design made of mild steel, with a color-coated green finish for durability and corrosion resistance. It has an opening size of 2 inches, a mesh number size of 11-50, and measures 5 feet in height.The structure includes 3 legs with 4 ties for enhanced stability during use. Weighing 3.5 kg, the item is lightweight yet sturdy, ensuring easy handling and installation. It is made from galvanized material, adding to its longevity and resistance to environmental factors. 50 Supply and Fixing of KL-3594 Aster-6 of 20W LED(2010X13X5.4)MM Supply of 20W Monocolour encapsulated flexible LED Strip having Dimension 2010 x 13 x 5.4 with IP 67, 3000K/4000K/5700K, 24Vdc CRI >80 MacAdam step>3, Beam angle : 120°, Should be equipped with dot less homogenous lighting effect, Electronic driver ON/OFF (External driver), MATERIAL CHARACTERISTICS, High-Grade Horizontal bend Elasto Polymer & Endcaps, Silicone moulded diffuser, End Cap, This luminaire contains built-in LED modules. LED modules are engineered accordingly to the existing regulations of Lumen Maintenance (LM80) and Technical Memorandum (TM21), Lifespan of the luminaire >60,000 hours at 40°C. Operating ambient temperature range is from -25°C to +55°C. Driver efficiency >85%, Surge protection 3KV. The OEM should have in house facility of encapsulation and in house testing laboratory. Certification: CE Certified, BIS Certification for Luminaires. Make as per Klite KL-3594/Unilamp/Ligman, 51 Supply and Fixing of integral 50W Post Top Dynasty Luminaire with ColourTemperature 3000K/4000K/5700K with luminous flux : 6128 / 5900 / 6224 lmrespectively, Maximum Voltage- 240 AVC CRI >80 MacAdam step 3 and LightDistribution 360° with CE and BIS certified IP 65 and IK09 Make in India Productwith having material characteristic Body : Die Cast Aluminum top cover withClear Polycarbonate Optical Lens, Mounting : Suitable for Ø60mm OD Pipe, Finish: Powder Coated Graphite Grey / Jet Black Anthracite and decorative knob onbottom, Gravity die cast aluminum (LM6 Grade) supporting arm integrated with die-cast aluminum base. SS fasteners with Pure polyester powder coated process& Acid treatment & pure polyester powder coating. For better lightingperformance Translucent acrylic diffuser of 2.7mm thickness with controlleddownward light emission, the translucent acrylic diffuser formed from nonyellowing acrylic sheet with lamp fixed position. Dimension of the Luminaireshould be Sq.325 x 560mm . This luminaire contains built-in LED modules. 52 Supply, Installation, Test in gand Commissioning of LEDRGB/RGBW flood lighting luminaire for facade lighting with Die- cast aluminium housing, powder- coated finish, of following wattage. Luminaire shall be capable of producing dynamic color changing light for with 16 million colors by DMX/ Ethernet based control. The be amangle of the fitting shall be narrow, medium, wide or asymmetric as per the requirement. Luminaire shall be complete with driver and capable of operating at line voltage without any separate power supply from 100-270 VAC, 50Hz with power factor>0.9. Fixture shall be suitable to operate at anambient temperature range of-10°Cto +50° C and shall be IP65 and IK06 rated. Life time shall be atleast L70:50000 burning hours at 50°C. Luminaire shall be conforming to BIS(IS10322) and shall be complete with all necessary accessories required for proper working of fixture in cluding weatherproof connection cables, waterproof connector setc. as required. 30 W 53 Design & Fabricating Ornamental work on mild steel (MS) sheets, which includes a series of detailed processes to achieve the desired design and finish through CNC cutting, which allows for precise and intricate patterns to be cut into the MS sheet based on the approved drawings and designs provided by the Architect in charge. Following the cutting process, etching and engraving are performed to add depth and detail to the design, enhancing the ornamental appearance. These processes involve carefully removing material from the surface to create the desired patterns and textures. After the cutting, etching, and engraving are completed, refilling is conducted to ensure the engraved areas are smooth and consistent with the overall design. This step ensures that the intricate details are highlighted and any imperfections are corrected. The MS sheet used for this work will be of an approved thickness to ensure structural integrity and durability. Additionally, the specification includes the cost of powder coating the MS sheet in an approved shade.(make Metaguise/Citadel/ Woodform Architectural or equivalent) 54 Supply of Spike light luminaire LED 3000K/4000K/5700K 240Vac CRI >80 Mac-Adam step 3, Input power 6W having Dimension 101 x Ø90 x 330 mm, Beam Angle : 40° with Electronic driver ON/OFF. CE and BIS Certified. LUMINAIRE TYPE Spike Mounted luminaire. IP rating IP66. MATERIAL CHARACTERISTICS Die-Cast aluminium housing & Front ring (grade ADC12 with testcertificate). Surface mounting spike made of Polypropylene black. Silicone clear gasket. SS fasteners. Mechanical resistance IK06. Pure polyester powder coated process : Acid treatment & pure polyester powder coating. LIGHTING PERFORMANCE Toughened Clear glass diffuser of 4mm thickness. This luminaire contains built-in LED modules. LED modules are engineered accordingly tothe existing regulations of Lumen Maintenance (LM80) and Technical Memorandum (TM21), Lifespan of the luminaire > 60,000 hours at 40ーC. Operating ambient temperature range is from -15ーC to +50ーC. Driver efficiency >84%, power factor >0.95, THD <10%, Surge protection 2.5KV. There may be changes in fixture selection and quantity as per architect intent. Make: K-Lite KL- 4265/Unilamp/Ligman 55 Supply and fixing of Tri Arc Terracotta Pavers: robust and aesthetic applications, having 3.5 tiles per square foot for coverage; tile weighs approximately 2 kg having terracotta finish as approved by Architect in charge make: Nuvocotto/or equivalent; thickness of 60 mm, ensuring durability and resistance to wear and tear. They are ideal for outdoor and heavy-traffic areas, providing both functionality and visual appeal.The scope of work includes delivering the pavers to the site and ensuring proper installation as per best practices. This involves preparing the base, aligning the tiles accurately, and securing them in place to achieve a durable and visually pleasing finish. 56 Bollard Light :Supply and fixing of LED Bollard robustly designed IP65/IK10 Bollard is easy to install with base plate(BCP150 LED /NWPSU 220-240V 7043)(K-litePhilips/Panasonic/Havells or Equivalent) 57 Supply, Installation, testing and commissioining of LSZH Speaker Cable 2C/14 AWG 2.5Sq.mm. Jkt Purple 152M Make: Bose/ L-Acoustic/ Powersoft 58 Supply and Fixing 24 Wattage Burial UNIIn Ground- Burial ip68 waterproof BBP343 LED2400/1800/WW 24W/18W 20D 100-240V (Philips/Siems/or Equivalent) 59 Supply, installation, testing and Commissioning of 5Core T Type 5C DMX cable 60 Supply of following siz of 1.1KV grade multicorealuminium conductor XLPE insulated and PVC shethed armoured cable as per IS 7098:1988 with up to date amendment 3.5 x 300 sq.mm. 61 Supply of 3000K/4000K/5700K In-ground 8W asymmetrical luminaire made up of die-casting with Ø116 stainless steel 316 grade front ring with silicone black gasket and toughened clear glass diffuser. With Electronic Driver, The luminous flux of the luminaire is upto 550 lm for 3000K BA- 35°/45° (Asy). The ingress protection is IP67 and impact resistance of IK08. The luminaire is integrated with high power NICHIA LED with CRI≥80, SDCM≤3, L70/ B10 @ 60000 Hrs at L70B10. The integral constant current driver comes with the power factor greater than or equal to 0.9, total harmonic distortion less than 15% with operating efficiency greater than 80% and a surge protection of 3KV. The driver input voltage 240Vac at 50-60Hz, operating voltage of 100- 277Vac and operating temperature of -20˚ ~ +40˚C with CE confirmed BIS approved. There may be changes in fixture selection and quantity as per architect intent Make: K-Lite KL-4098, Unilamp/ Ligman 62 Providing, fabricating and fixing/ erection of 6mm SS plate backlitted at desired location as per approved drawing of OLDEST BANYAN TREE NARORA, BULANDSHAHR,or as approved by Client department having Helvetica Font with 400mm size Also including cost of providing and fixing of fasteners complete in all respects as per Architect in charge 63 Supply and fixing of Tri Arc Terracotta Pavers: robust and aesthetic applications, having 3.5 tiles per square foot for coverage; tile weighs approximately 2 kg having terracotta finish as approved by Architect in charge make: Nuvocotto/or equivalent; thickness of 60 mm, ensuring durability and resistance to wear and tear. They are ideal for outdoor and heavy-traffic areas, providing both functionality and visual appeal.The scope of work includes delivering the pavers to the site and ensuring proper installation as per best practices. This involves preparing the base, aligning the tiles accurately, and securing them in place to achieve a durable and visually pleasing finish. 64 Supply, Installation, testing and commissioining of Yamaha PX3 Power Amplifier Make: Bose/ L-Acoustic/ Powersoft 65 Supplying and laying ofaluminium conductor PVC insulated armoured served sheathed cable 1100 volts grade at the depth of 750 mm bellow ground level over a cushion of 75 mm thick sand all around and protected with burnt bricks on side and on top .On surface the cable run shall be fixed on MS clamps etc.of suitable size or as directed bythe Engineer-Incharge ,complete in all respect.The armouring of the cable shall be properly connected with the earth conductor by clamps etc. Following size size 10 sq mm x 4 core 66 12 mm Brick tile work for wall lining over required bed of cement mortar 1:3 (1 cement : 3 coarse sand) and cement slurry @ 3.3 kg/Sqm including pointing in white cement complete. 67 supply and fixing following capacity of automatic street light cubicle control pannel with anti corrosive alkali and acid proof paint consisting of time switch TSO 100 seeries with contactors, HRC fuse, isolating switch, metering instrument and instrument box with CTs etc.complete in all respect. 40 A SPN 68 Supply and Laying a water soluble penetrative solution for waterproofing of masonry building material & Nano technology based as it provides molecular level hydrophobicity to inorganic substrate .The product is based on organosilicon chemistry, hence reacts with the inorganic substrate surface, seals the surface uto a depth of 2-3 mm and provides long service life where Nano size allows penetration deep into substrate that provides 20+ years water repellency.(Zycosil/Pratt & Lamber or Equivalent) including cost of all materials, labour tools and plants etc. required for proper completion of the work. 69 Supplying, fabricating, transporting, hoisting and fixing in position good quality of 70 mm red sandstone in various elements for all levels. Stone shall be free from cracks, lines stains and even in shade for each element. The stone shall be fine grained and reddish or buff-colored (locally available). The work shall be carried out as per attached drawings with different process of i.e carving (manual/ by machine), ornamental work, traditional work, figure work (any type, any size), CNC cutting, moulding. The carving and molding work shall be of very good quality. The stones to be fixed in line, level and plumb in all respect with the use of brass clamps, pins, (to be paid separetely) dowels, cement slurry with matching pigment and Epoxy of Akemi Germany, Ardex Endura, MYK laticrete or approved make as required and as approved by the Architects. 70 Supply & fixing clay tiles of 10X16 inches on roof including the cost of Ridge, typical caly tile, edge tiles and inlcusion of glass tiles in color and finish as per drawing approved from Architect in charge, and supply of all materials labours & tools etc required for safe erection and cost of adhesive, waterproof membrane and MS frame of L profile/rectangular hollow sections required for fixing and supprting the tiles., also includes the cost of all the necessary fitting and required for completion of the work as per Engineer in charge. 71 Design & Fabricating Ornamental work on mild steel (MS) sheets, which includes a series of detailed processes to achieve the desired design and finish through CNC cutting, which allows for precise and intricate patterns to be cut into the MS sheet based on the approved drawings and designs provided by the Architect in charge. Following the cutting process, etching and engraving are performed to add depth and detail to the design, enhancing the ornamental appearance. These processes involve carefully removing material from the surface to create the desired patterns and textures. After the cutting, etching, and engraving are completed, refilling is conducted to ensure the engraved areas are smooth and consistent with the overall design. This step ensures that the intricate details are highlighted and any imperfections are corrected. The MS sheet used for this work will be of an approved thickness to ensure structural integrity and durability. Additionally, the specification includes the cost of powder coating the MS sheet in an approved shade.(make Metaguise/Citadel/ Woodform Architectural or equivalent) 72 Supply & Erection of factory fabricated & wired metal clad dust and vermin proof mounting, M.S Channel Base with botom and top cable entreis Electrical control panel with TPN ACB (65KA, 4 Pole Elect draw out Micor Processer Release IPR2) and TPN MCCBs (four Pole 36 KA with thermal magnatic release) switches and instrument chamber etc. complete in all respect. The instrument chamber shall be separate and shall comprise of flush type/digital ammeter Voltmeter, Selector switches for ammeter and Voltmeter, instrument fuses current transformer etc. The Board shall have suitable capacity electrolytic aluminium busbars as per IS8623 insulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/DMC support with deteachable side covers and shall be suitable for extension on the sides. The switches enty boxes shall be complete with suitable cable end boxes reverse. The job includes the grounting of the board as per directions of Engineer-in-charge. All out goings of 100 Amp. and above will be provided with Amp. Metre, curent transformer and selector switches etc. and insurment fuse The switch board shall be fabicated with CRCA sheet with a minimum thickness of 1.6mm/2mm. Cubical type switch board shall be of cat A & B only.FEEDER PANEL -1Incoming :One (1) No 63 Amp. 4P MCCB of 25KABreaking capacity Bus Bar :One (1) No. 100 Amp.TPN aluminimum bus bar of suitable length.Outgoing :Phase indication lamps on each outgoing to be provided.40 Amps DP MCB of 10KA - 2 No16 Amps DP MCB of 10KA - 12 No2 No. SPACE & SPAREPanel described as above 73 Supply and Fixing of Spike Light for trees 12 watt Warm White. (Including civil works) 74 Supply of submersible pump (3.7KW/5.0 HP) of make KSB (Cora) for 200 lit/min discharge at 50 meter head with control panel, support wire etc complete. 75 Supply of submersible pump (3.7KW/5.0 HP) of make KSB (Cora) for 200 lit/min discharge at 50 meter head with control panel, support wire etc complete. 76 Supply of 125 mm dia MSpipe as per IS1239 77 Supply and Installation of Cylin 30W ceiling mounted compact downlight. Type IV Medium light distribution. Luminaire made of extruded aluminium, pressure die-cast aluminium alloy of high corrosion resistance and non corrosive stainless steel fasteners. Clear toughened glass of 4mm thickness. Gravity die cast aluminium plate for surface mounting on ceiling. Polycarbonate optical lens for higher efficiency, lower optical losses with optimum glare suppression. Single cable entrance via PG7 cable gland. Protection class IP65. Mechanical resistance IK07. Pure polyester powder coated graphite grey / anthracite grey / jet black. Make as per KL-3629/ Ligman/ Unilamp. Available colour temperature 3000K / 4000K / 5700K, Colour rendering index (CRI)>70. SDCM-3 MacAdam. K-Lite LED module with expected service life of at least 50,000 operating hours. Prewired with LED driver and suitable for operating on 240V, 50Hz single phase ac supply. Luminaire dimension : 166mm diameter x 160mm height. CE & BIS Certified. 78 Supply of 125 mm dia MSpipe as per IS1239 79 Supply & fixing Ornamental clay tiles of 10X16 inches for ceiling including the cost of Ridge, typical caly tile, edge tiles and inlcusion of glass tiles in color and finish as per drawing approved from Architect in charge, and supply of all materials labours & tools etc required for safe erection and cost of adhesive, waterproof membrane also includes the cost of all the necessary fitting and required for completion of the work as per Engineer in charge. 80 Supplying and laying ofaluminium conductor PVC insulated armoured served sheathed cable 1100 volts grade at the depth of 750 mm bellow ground level over a cushion of 75 mm thick sand all around and protected with burnt bricks on side and on top .On surface the cable run shall be fixed on MS clamps etc.of suitable size or as directed bythe Engineer-Incharge ,complete in all respect.The armouring of the cable shall be properly connected with the earth conductor by clamps etc. Following size size 6 sq mm x 2 core 81 Supply installation commissioning of following sizes of power and data cable as mentioned:3C x 4 sqmm Cu unarmored multistrand 82 Supply, installing, testing and commissioning of non clog submersible type drainage / dewatering pumpset Product Type: SUBMERSIBLE DRAINAGE PUMPProduct ConfigurationPump Classification: Standard PumpComponent MaterialsVolute Material: Cast Iron FG 260Impeller Material: Cast Iron FG 260Shaft Material: S.S AISI 410Seal Material: Carbon/Ceramic/NBR/S.S 304Motor SpecificationsPhase: 3Voltage: 380-415VCable Length: Standard - 5 metresCable Length: Additional - 0 metres: 0Pipework ConnectionFloat Switch: With Float SwitchSolids Diameter LimitMaximum Solids Diameter: 10 mm Flow Rate = 205 LPM Each Pump Head = 9m Each Pump Set Detail = 1W+1S ( FOR EXTERNAL) 83 Product Type: SUBMERSIBLE DRAINAGE PUMPProduct ConfigurationPump Classification: Standard PumpComponent MaterialsVolute Material: Cast Iron FG 260Impeller Material: Cast Iron FG 260Shaft Material: S.S AISI 410Seal Material: Carbon/Ceramic/NBR/S.S 304Motor SpecificationsPhase: 3Voltage: 380-415VCable Length: Standard - 5 metresCable Length: Additional - 0 metres: 0Pipework ConnectionFloat Switch: With Float SwitchSolids Diameter LimitMaximum Solids Diameter: 10 mm Flow Rate = 205 LPM Each Pump Head = 9m Each Pump Set Detail = 1W+1S ( FOR EXTERNAL) 84 Providing & fixing Cobble Stone Flooring (10X10X10)cm filling of joints in 1:3 Cement mortarwith matching colour pigments all complete specification & direction of Engineer in charge 85 Supply, installation, testing and Commissioning of 2Core 2C DMX cable/Patch cord Patch Endcap 1m 86 Transport of boring tools other required equipements and installation at site. 87 Supply and Installation of 3000K/ 4000K/ 5700K Sill Luminaire with maximum wattage 6W made of Die cast aluminium housing with SS fasteners. Pre treated with silicone gaskets and provided with Die-cast aluminium mounting plate with pure polyester powder coating. Mechanical resistance IK08. The luminaire shpuld undergone Acid treatment & pure polyester powder coating. For LIGHTING PERFORMANCE Optical grade clear polycarbonate lens is provided and Lamp in fixed position. This luminaire contains built-in LED modules. Dimension of the luminaire should be maximum 150mm x 90mm x 43mm. LED modules are engineered accordingly to the existing regulations of Lumen Maintenance (LM80) and Technical Memorandum (TM21), Lifespan of the luminaire > 60,000 hours at 40°C. IP rating of the product will be IP65. Operating ambient temperature range is from -15°C to +50°C. Driver efficiency >70%, power factor >0.95, THD <10%, Surge protection 2.5KV. Make as per KL-3078/ Ligman/ Unilamp. CE & BIS Certified. 88 Transport of boring tools other required equipements and installation at site. 89 Supply and fixing of TG RO43 BETA, powder coated Tree guard as per design approved by Architect in charge with the following specifications:The unit is in powder form, packed in a 5Kg drum for secure handling and transportation. The product features a cylindrical design made of mild steel, with a color-coated green finish for durability and corrosion resistance. It has an opening size of 2 inches, a mesh number size of 11-50, and measures 5 feet in height.The structure includes 3 legs with 4 ties for enhanced stability during use. Weighing 3.5 kg, the item is lightweight yet sturdy, ensuring easy handling and installation. It is made from galvanized material, adding to its longevity and resistance to environmental factors. 90 Providing machine made Wire Cut Bricks where edges are sharp and borders are straight and Size of8.5x 4x3having Smooth surface finish with Compression Strength should be less than 105 kg/sq cm and Water absorption should not exceed 20%. Thickness of 230mm wall Ground Floor 91 FEEDER PANEL -2Incoming :One (1) No 40 Amp. 4P MCCB of 25KABreaking capacity Bus Bar :One (1) No. 63 Amp.TPN aluminimum bus bar of suitable length.Outgoing :Phase indication lamps on each outgoing to be provided.16 Amps DP MCB of 10KA - 8 No2 No. SPACE & SPAREPanel described as above 92 Providing, fabricating and fixing/ erection of 6mm SS plate backlitted at desired location as per approved drawing of 500 YEAR OLD BANYAN TREE ,having Helvetica Font with 300mm size Also including cost of providing and fixing of fasteners complete in all respects as per Architect in charge 93 Supply and laying with 32MM GI pipe ISI DSR SI 2831 as per site requirement 94 Supplying and laying ofaluminium conductor PVC insulated armoured served sheathed cable 1100 volts grade at the depth of 750 mm bellow ground level over a cushion of 75 mm thick sand all around and protected with burnt bricks on side and on top .On surface the cable run shall be fixed on MS clamps etc.of suitable size or as directed bythe Engineer-Incharge ,complete in all respect.The armouring of the cable shall be properly connected with the earth conductor by clamps etc. Following size 50 sq mm x 3-1/2core 95 Providing and injecting HM-500 Epoxy Anchoring Type: HM-500 : Red or Black Density: 1.5±0.1g/cm³ in proportion Mix Ratio: 3:1 Color/ or recommended by the manufacturer into drills cracks/honey-comb area of concrete/masonry by suitable gun/pump at required pressure including cutting of nipples after curing etc. complete as per directions of Engineer-in-Charge. (make Hilti/HM or equivalent) 96 Supply and Installation of 30W Extruded aluminium Luminaire with Tree Strap. Module fixing clamp made of galvanized CRCA sheet 3mm thickness. SS fasteners. IP Rating should be IP65 with different beam angles as per the requirement 10° / 28° / 45°. Clear silicone gaskets. Die-cast aluminium mounting plate Ø100.5 x 4mm thick with 2 elongated holes 15 x 10 to suit M8 bolts at PCD 55 with pure polyester powder coating. Mechanical resistance IK07. The luminaire should have undergone Acid treatment & pure polyester powder coating. For better LIGHTING PERFORMANCE Clear polycarbonate optical cover with light emission at desired angle. Lamp fixed position. Colour Temperature should be as per 3000K, 4000K, 5700K 230-240Vac CRI >80 MacAdam step 3. This luminaire contains built-in LED modules. LED modules are engineered accordingly to the existing regulations of Lumen Maintenance (LM80) and Technical Memorandum (TM21), Lifespan of the luminaire > 60,000 hours at 40°C. Operating ambient temperature range is from -15°C to +50°C. Driver efficiency >85%, power factor >0.95, THD <10%, Surge protection 4KV. Make as per KL-4286 with Kl-8275/ Ligman/ Unilamp. CE & BIS Certified. 97 Supply & fixing of recess mounting round 15 to 18 watt LED down Lighter having Powder coated die cast aluminium housing with heat sink , diffuser /reflector and driver with theft protection set complete in all respect. 98 Supply of Surface mounted spot light LED 3000K/4000K/5700K 240Vac CRI >80 MacAdam step 3 Input power : 10W Dimension Ø95 x 124 mm, Beam Angle : 40° without Electronic driver ON/OFF, LUMINAIRE TYPE : Wall Mounted luminaire. IP rating IP66. MATERIAL CHARACTERISTICS: Die-Cast aluminium housing & Front ring (grade ADC12 with test certificate). Surface mounting Bracket made of Polypropylene black. Silicone clear gasket. SS fasteners. Mechanical resistance IK06. Pure polyester powder coated process : Acid treatment & pure polyester powder coating. LIGHTING PERFORMANCE: Toughened Clear glass diffuser of 4mm thickness. This luminaire contains built-in LED modules. LED modules are engineered accordingly to the existing regulations of Lumen Maintenance (LM80) and Technical Memorandum (TM21), Lifespan of the luminaire > 60,000 hours at 40ーC. Operating ambient temperature range is from -15ーC to +50ーC. Driver efficiency >84%, power factor >0.95, THD <15%, Surge protection 2.5KV. Make: K-Lite Model no.-KL-4245/Unilamp/Ligman 99 Supply and Installation of Wall-mounted 6W compact wall quad down light emission designed to use monochromatic Warm white (3000K) & Neutral white (4000K). Hybrid optics with lens & mirror finish pure aluminium reflector combination for higher efficiency, lower optical losses with optimum glare suppression. Extruded aluminium section with inner grooves to fix the top and bottom frame (grade 6063) 100 x 3mm thickness, die-cast aluminium glass fixing frame 100mm with clear toughened glass diffuser of 4mm thickness with ceramic black coated on outer corner siliconed to frame & die-cast aluminium top closing frame ?100mm (ADC12). Die-cast aluminium heat sink for excellent thermal management. Single cable entrance via black PG7 cable gland, Die cast aluminium base for surface mounting on wall (ADC12). All external screws are made of stainless steel. Clear silicone gasket. Protection class IP65. Mechanical resistance IK07. Acid treatment & pure polyester powder coated graphite grey / anthracite grey / jet black. Make as per Kl-3635/ Ligman/ Unilamp. The luminaires built-in LED module are engineered accordingly to the existing regulations of Lumen Maintenance (LM80) and Technical Memorandum (TM21). Operating ambient temperature range is from -15°C to +50°C. Beam angle 15° / 25° / 40°, colour rendering index (CRI)>80. Prewired with LED driver and suitable for operating on 240V, 50Hz single phase ac supply. Driver efficiency >80%, Power factor >0.90, THD <10%, Surge protection 2.5KV. Luminaire dimension : 150mm length x 100mm width x 150mm height. CE & BIS Certified. 100 Constructing brick masonry INSPECTION chamber 60x60x75 cm with bricks of class designation 50 in cement mortar 1:4 (1 cement : 4 coarse sand) including CI cover with frame LIGHT WEIGHT complete as perdesign. With FPS bricks 101 Drilling of 200 mm dia bore hole. 102 Drilling of 200 mm dia bore hole. 103 Supply of following siz of 1.1KV grade multicorealuminium conductor XLPE insulated and PVC shethed armoured cable as per IS 7098:1988 with up to date amendment 3.5 x 240 sq.mm. 104 Supplying and laying ofaluminium conductor PVC insulated armoured served sheathed cable 1100 volts grade at the depth of 750 mm bellow ground level over a cushion of 75 mm thick sand all around and protected with burnt bricks on side and on top .On surface the cable run shall be fixed on MS clamps etc.of suitable size or as directed bythe Engineer-Incharge ,complete in all respect.The armouring of the cable shall be properly connected with the earth conductor by clamps etc. Following sizesize 6 sq mm x 2 core 105 Supply and Laying a water soluble penetrative solution for waterproofing of masonry building material & Nano technology based as it provides molecular level hydrophobicity to inorganic substrate .The product is based on organosilicon chemistry, hence reacts with the inorganic substrate surface, seals the surface uto a depth of 2-3 mm and provides long service life where Nano size allows penetration deep into substrate that provides 20+ years water repellency.(Zycosil/Pratt & Lamber or Equivalent) including cost of all materials, labour tools and plants etc. required for proper completion of the work. 106 Supply of following siz of 1.1KV grade multicorealuminium conductor XLPE insulated and PVC shethed armoured cable as per IS 7098:1988 with up to date amendment 3.5 x 35 sq.mm 107 Supply and Fixing of Spike Light for trees 12 watt Warm White. (Including civil works) 108 Supplying and laying ofaluminium conductor PVC insulated armoured served sheathed cable 1100 volts grade at the depth of 750 mm bellow ground level over a cushion of 75 mm thick sand all around and protected with burnt bricks on side and on top .On surface the cable run shall be fixed on MS clamps etc.of suitable size or as directed bythe Engineer-Incharge ,complete in all respect.The armouring of the cable shall be properly connected with the earth conductor by clamps etc. Following size size 6 sq mm x 2 core 109 Supply of Zedo Round Surface Mounting Light 110 Supply, installation, testing & commissioning of DMX Signal Amplifier to boost the Signal, IP 65 rated module to enahce the depleting DMX Signals, should have IP 66/67 rates inbuilt connectors compatible with Luminaires. It should be offered with inbuilt electronic ciruit for functioning. 111 Supply and Laying a water soluble penetrative solution for waterproofing of masonry building material & Nano technology based as it provides molecular level hydrophobicity to inorganic substrate .The product is based on organosilicon chemistry, hence reacts with the inorganic substrate surface, seals the surface uto a depth of 2-3 mm and provides long service life where Nano size allows penetration deep into substrate that provides 20+ years water repellency.(Zycosil/Pratt & Lamber or Equivalent) including cost of all materials, labour tools and plants etc. required for proper completion of the work. 112 Supply of following siz of 1.1KV grade multicorealuminium conductor XLPE insulated and PVC shethed armoured cable as per IS 7098:1988 with up to date amendment 4 x 16 sq.mm 113 Supply of 125 mm dia slotted MSpipe 114 Supply and Installation of Adjustable 12W Trisha round luminaire Ceiling-mounted recess down light. Beam angle 15° / 25° / 38°/ 60°. Die-cast aluminium housing with heat sink for excellent thermal management. Metallized thermoplastic reflector with anti-scratch protection treatment with high luminous efficiency and visual comfort. Protection class IP20. Powder coated white. Available colour temperature WW / NW, Colour rendering index (CRI)>80. K-Lite LED module with expected service life of at least 60,000 operating hours. Make should be as per KL-8178 with KL-7081/ Ligman/ Unilamp. Prewired with LED driver and suitable for operating on 240V, 50Hz single phase ac supply. Driver efficiency >87%, Power factor >0.95, THD< 10%, Surge protection 3KV. Luminaire dimension : 80mm diameter x 104mm height. C.O.D : 50mm diameter. BIS & CE Certified. 115 Supply of 125 mm dia slotted MSpipe 116 Supply of RADO MINI Wall light 117 Fixing, testing and commissioning for erection and lowering of submersible pump, 65 mm dia GI column pipe, 3 core submersible copper cable upto the control panel, supporting clamps, cable clips, pressure gauge, connection line and all other accessories required for the proper completion of the work. 118 Fixing, testing and commissioning for erection and lowering of submersible pump, 65 mm dia GI column pipe, 3 core submersible copper cable upto the control panel, supporting clamps, cable clips, pressure gauge, connection line and all other accessories required for the proper completion of the work. 119 Providing & fixing White River (Stone) Pebbles size of 2 to 2.5 dia in natural colour at site of work including loading, unloading, carriage and all taxes paid etc.and as per direction of officer in charge. 120 12 mm Brick tile work for wall lining over required bed of cement mortar 1:3 (1 cement : 3 coarse sand) and cement slurry @ 3.3 kg/Sqm including pointing in white cement complete. 121 Extra for forming cavity 5 cm to 11.5 cm wide in cavity walls with necessary weep and vent holes including use of cores and cost of providing and fixing bitumastic coated M .S. ties 350 mm long of 25x3 mm section at not less than 3 ties per sqm as per approved design. 122 Supply & Installation Of-UNICOPro Welded Mesh Modular FenceSystem.Panel: Galvanised MS Wires.Post: Galvanised MS.Panel Height: 1560 mm.Panel Width: 2500 mm.Mesh Aperture: 50 mm x 200 mm.Wire Diameter: H-4.5 mm, V-4.5 mm.Post Type: H-Profile.Post Height: 1600 mm.Mounting Type: Base Plate.Surface Finish: Pure PolyesterCoating/Over 65 Microns/1000 HoursSalt Spray Tested.Colour Code: RAL 6005 (Moss Green). 123 Supply of following siz of 1.1KV grade multicorealuminium conductor XLPE insulated and PVC shethed armoured cable as per IS 7098:1988 with up to date amendment 3.5 x 25 sq.mm. 124 Supply and Installation of 1.5 HP Submersible pump set complete 125 Providing, fixing, jointing and testing ,ofPVC Multi Floor Trap without jali ofminimum 50 mm water seal, making necessarycuttingin slabor floors and making goodincluding supports with cement concrete 1:3:6complete as approved by Engineer-in-Charge.110mm x 75mm x 50mm/40mm (Toilet) 126 Providing and fixing 65 mm dia. G.I. pipe complete with fittings and clamps including cutting and making good the wall etc. (from submersible pump to ground level) 127 Providing and fixing 65 mm dia. G.I. pipe complete with fittings and clamps including cutting and making good the wall etc. (from submersible pump to ground level) 128 Supply of following siz of 1.1KV grade multicorealuminium conductor XLPE insulated and PVC shethed armoured cable as per IS 7098:1988 with up to date amendment 3.5 x 50 sq.mm 129 Electric logging of bore hole 130 Supply and fixing of tube well accessories i.e. well cap, clips, clamps, etc. to complete the job in all respect. 131 Supply and fixing of tube well accessories i.e. well cap, clips, clamps, etc. to complete the job in all respect. 132 Providing and fixing ISI marked S.S. Tower bolts black finish, (Barrel Type) with necessaryscrews etc. complete(a) 250 mm x 10mm 133 Supplying of following size exhaust fan complete with gravity louver and connection with 3 core flexible wire as required.300mm EXHAUST FAN 134 Providing and fixing 12 mm thick frameless toughened glass of approved brand and manufacture, includingnecessary holes etc. for fixing required fittings, all complete as per direction of Engineer-in-charge. 135 Supply and fixing of UPVC S.W.R. pipe type -B confirming to IS- 13592 including jointing the pipes with rubber ring, lubricant and UPVC SWR cuplar confirming to IS - 14735. Also including excavation of trenches cutting of walls and holes and repairing the walls floors and refilling the trenches as before but excluding supply and cost of other fittings such as elbow, bead, tee and Y-tee including supply of all material labour and T&P .Required for proper completion of the work.160 mm O.D. 136 Lowering of 125 mm dia MS pipe in bore hole including cutting,jointing etc complete. 137 Lowering of 125 mm dia MS pipe in bore hole including cutting,jointing etc complete. 138 Providing and fixing ISI marked S.S. Sliding door bolts with nuts and screws etc. complete(a) 300 mm x 16mm 139 Supplying of LED mirror light luminaire with 10Wwatt complete with electronic ballast, lamp including connection etc. complete as required, Including connection with 1.5 sqmm FRLS PVC insulated copper conductor. 140 Supply & fixing of 12 Watt LED Bulb - B22 / E27 (Colour Temp.- 6500K / Lumens - 900 lm) cool day light, Input Volts (AC 90V-260V), 3-Star rating suitable for Batten/Angle holder including making connection.Complete in all respect. 141 Providing and fixing ISI marked S.S. handles conforming to IS 4992 with necessary screws etc. complete.125mm 142 Providing and packing of coarse sand / pea gravel around the pipe. 143 Supply and laying of Chetan 1.5 Mtr RCA Male to XLR MaleCable Make: Bose/ L-Acoustic/ Powersoft 144 Providing and packing of coarse sand / pea gravel around the pipe. 145 Providing, fixing, jointing and testing , ofPVC NahaniTrap without jali ofminimum 50 mm water seal, making necessarycuttingin slabor floors and making goodincluding supports with cement concrete 1:3:6complete as approved by Engineer-in-Charge.110mm x 75mm (Toilet & Kitchen) 146 Supply & fixing of 225/230mm sweep ventilating (Light Duty) exhaust fan complete with Metallic Blade (Steel bird guard protector /Copper motor for high air suction performance /Capacitor etc.), Noise level : (45 - 50) dB, Power consumption : 45 W, Rated voltage : 230 V, Rated frequency : 50 Hz, Motor type : Normal Speed. Complete in all respect. 147 Supply and Fixing Mirror Light(Philips/Siems/or Equivalent) 148 Supply & fixing of 225/300mm sweep ventilating (Light Duty) exhaust fan complete with Metallic Blade (Steel bird guard protector /Copper motor for high air suction performance /Capacitor etc.), Noise level : (45 - 50) dB, Power consumption : 45 W, Rated voltage : 230 V, Rated frequency : 50 Hz, Motor type : Normal Speed. Complete in all respect. 149 Supply and fixing of nylon jali around the slotted pipes complete as required. 150 Testing and development of tube well. 151 Supply and fixing of nylon jali around the slotted pipes complete as required. 152 Testing and development of tube well. 153 Supplying and laying ofaluminium conductor PVC insulated armoured served sheathed cable 1100 volts grade at the depth of 750 mm bellow ground level over a cushion of 75 mm thick sand all around and protected with burnt bricks on side and on top .On surface the cable run shall be fixed on MS clamps etc.of suitable size or as directed bythe Engineer-Incharge ,complete in all respect.The armouring of the cable shall be properly connected with the earth conductor by clamps etc. Following size size 6 sq mm x 2 core 154 Providing 3 core PVC insulated submersible cable. (from pump panel to submersible pump) 155 Providing 3 core PVC insulated submersible cable. (from pump panel to submersible pump) 156 Supply and fixing of 3 watt to 6 watt LED(spot light) fitting Confirming to IP 65 and above protection Complete in all respect. CAT. - AAA (Use as a Decorative Mirror Light) 157 Supply and fixin g of UPVC S.W.R. Nahni trap size 100/75mm, 100/90mm confirming to IS - 14735 self cleannig design fixed in PCC 1:2:4 and supply and fixing of 125mm dia heavy duty CP brass jali. 158 Supply and fixing of UPVC S.W. R. Gully trap confirming to IS - 14735 size 150x110 mm dia of self cleaning design including fixed brick Masonary chamber 250x250x250mm Size i/ c supply and fixing of CI cover with frame weight not less then 4.50Kg. & CI grating 150x150mm complete in all respects. 159 Supply and Laying a water soluble penetrative solution for waterproofing of masonry building material & Nano technology based as it provides molecular level hydrophobicity to inorganic substrate .The product is based on organosilicon chemistry, hence reacts with the inorganic substrate surface, seals the surface uto a depth of 2-3 mm and provides long service life where Nano size allows penetration deep into substrate that provides 20+ years water repellency.(Zycosil/Pratt & Lamber or Equivalent) including cost of all materials, labour tools and plants etc. required for proper completion of the work. 160 Extra for forming cavity 5 cm to 11.5 cm wide in cavity walls with necessary weep and vent holes including use of cores and cost of providing and fixing bitumastic coated M .S. ties 350 mm long of 25x3 mm section at not less than 3 ties per sqm as per approved design. 161 Supply and fixing of brass nickle plated compression gland for pvc insulated & armoured served sheaththed ,underground cable including rubber ring etc. complete in all respect. Thearmouring of the cable shall be properly connected with the earthas per direction of engineer-incharge. for cable size 10 sq mm x 4 core 162 Supply, fixing, testing and commissioning of Level Float Switch, for dry run protection of pump as per specifications:-Lehry Make Level Float Switch1) Body: Polypropylene, Highly Durable, Water Proof2) Rating : IP683) Temperature : 0-50DegC 4) Cable : PVCSize 5 Mtr, Item Code (LIV-LFV-RED- MTR)(location : UG TANK) 163 Supply, fixing, testing and commissioning of Level Float Switch, for dry run protection of pump as per specifications:-Lehry Make Level Float Switch1) Body: Polypropylene, Highly Durable, Water Proof2) Rating : IP683) Temperature : 0-50DegC 4) Cable : PVCSize 5 Mtr, Item Code (LIV-LFV-RED- MTR)(location : UG TANK) 164 Supply and fixing of LED 18w Round Sky Glow Next Gen LED Downlight fitting 18 watt suitable with complete Including tube suitable for both surface & suspended complete in all respect.CAT. - AAA 165 Supply and fixing ofplain or pin type copper tin plated cable socket (lug) to cable leadsfor pvc insulated & armoured cable insulating with tape and making connection. complete in all respect as per direction of engineer -incharge. for cablesize 10 sq mm 166 Supply and fixing of UPVC S.W. R. Gully trap confirming to IS - 14735 size 150x110 mm dia of self cleaning design including fixed brick Masonary chamber 250x250x250mm Size i/ c supply and fixing of CI cover with frame weight not less then 4.50Kg. & CI grating 150x150mm complete in all respects. 167 Supply and fixing ofplain or pin type copper tin plated cable socket (lug) to cable leadsfor pvc insulated & armoured cable insulating with tape and making connection. complete in all respect as per direction of engineer -incharge. for cablesize 6 sq mm 168 Supply and fixing of brass nickle plated compression gland for pvc insulated & armoured served sheaththed ,underground cable including rubber ring etc. complete in all respect. Thearmouring of the cable shall be properly connected with the earthas per direction of engineer-incharge. for cable size 6 sq mm x 2 core 169 Supply and fixing of UPVC S.W.R. Door Y confirming to IS- 1473110 mm size 170 Providing and fixing 65 mm dia. brass gate valve with CI wheel of approved quality. 171 Providing and fixing 65 mm dia. brass gate valve with CI wheel of approved quality. 172 Supply and fixing of UPVC S.W.R. Door Y confirming to IS- 14735 90 mm size 173 Design & Fabricating Ornamental work on mild steel (MS) sheets, which includes a series of detailed processes to achieve the desired design and finish through CNC cutting, which allows for precise and intricate patterns to be cut into the MS sheet based on the approved drawings and designs provided by the Architect in charge. Following the cutting process, etching and engraving are performed to add depth and detail to the design, enhancing the ornamental appearance. These processes involve carefully removing material from the surface to create the desired patterns and textures. After the cutting, etching, and engraving are completed, refilling is conducted to ensure the engraved areas are smooth and consistent with the overall design. This step ensures that the intricate details are highlighted and any imperfections are corrected. The MS sheet used for this work will be of an approved thickness to ensure structural integrity and durability. Additionally, the specification includes the cost of powder coating the MS sheet in an approved shade.(make Metaguise/Citadel/ Woodform Architectural or equivalent) 174 Supply and fixing of UPVC S.W.R. Plain Tee confirming to IS- 14735110x110x110 mm size 175 Supply and fixing of UPVC S.W.R. Plain Tee confirming to IS- 1473590x90x90 mm size 176 Supply and fixing of UPVC S.W.R. door bend confirming to IS- 14735110 mm size 177 Supply and fixing of UPVC S.W.R. door bend confirming to IS- 1473590 mm size 178 Supply and fixing of UPVC S.W.R. Plain bend confirming to IS- 14735110 mm size 179 Supply and fixing of UPVC S.W.R. Plain bend confirming to IS- 14735 90 mm size 180 Supply and fixing of brass nickle plated compression gland for pvc insulated & armoured served sheaththed ,underground cable including rubber ring etc. complete in all respect. Thearmouring of the cable shall be properly connected with the earthas per direction of engineer-incharge. for cablesize 50 sq mm x 3-1/2core 181 Supply and fixing ofplain or pin type copper tin plated cable socket (lug) to cable leadsfor pvc insulated & armoured cable insulating with tape and making connection. complete in all respect as per direction of engineer -incharge. for cablesize 50 sq mm 182 Supply and fixing of UPVC S.W.R. Cowel confirming to IS- 14735110 mm size 183 Supply and fixing of brass nickle plated compression gland for pvc insulated & armoured served sheaththed ,underground cable including rubber ring etc. complete in all respect. Thearmouring of the cable shall be properly connected with the earthas per direction of engineer-incharge. for cablesize 6 sq mm x2 core 184 Supply and fixing of UPVC S.W.R. Cowel confirming to IS- 1473590 mm size 185 Supply and fixing ofplain or pin type copper tin plated cable socket (lug) to cable leadsfor pvc insulated & armoured cable insulating with tape and making connection. complete in all respect as per direction of engineer -incharge. for cablesize 25 sq mm 186 Supply and fixing of brass nickle plated compression gland for pvc insulated & armoured served sheaththed ,underground cable including rubber ring etc. complete in all respect. Thearmouring of the cable shall be properly connected with the earthas per direction of engineer-incharge. for cablesize 6 sq mm x2 core 187 Supply and fixing ofplain or pin type copper tin plated cable socket (lug) to cable leadsfor pvc insulated & armoured cable insulating with tape and making connection. complete in all respect as per direction of engineer -incharge. for cablesqmm 6.00 188 Supplying, erection, connecting, testing and commissioning of 400 mm Wall Fancomplete in all respect. 189 Controllers for above RGBW Luminiaries 190 Supply of following siz of 1.1KV grade multicorealuminium conductor XLPE insulated and PVC shethed armoured cable as per IS 7098:1988 with up to date amendment 4 x 16 sq.mm 191 Supply of following siz of 1.1KV grade multicorealuminium conductor XLPE insulated and PVC shethed armoured cable as per IS 7098:1988 with up to date amendment 3 x 6 sq.mm, 192 Constructing brick masonary open surface drain with bricks of class designation 75 in cement mortar 1:4 (1 cement : 4 fine sand) including earth excavation, 10cm thick bed concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size) and 25mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 12.5mm nominal size) for filling haunches including 12mm cement plaster 1:4 (1 cement : 4 coarse sand ) with a floating coat of neat cement inside the drain, its top and exposed side including disposal of surplus earth complete as per standard design:Drain 450 wide average.Depth 60 cm with R.C.C. slab 193 Constructing brick masonary open surface drain with bricks of class designation 75 in cement mortar 1:4 (1 cement : 4 fine sand) including earth excavation, 10cm thick bed concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size) and 25mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 12.5mm nominal size) for filling haunches including 12mm cement plaster 1:4 (1 cement : 4 coarse sand ) with a floating coat of neat cement inside the drain, its top and exposed side including disposal of surplus earth complete as per standard design:Drain 600 wide average.Depth 90 cm with R.C.C. slab 194 Supply and Installation of 3W Static White 3000K Sudo Step Light, Should be rectangular compact and robust wall recessed luminaires for illuminating walls and stairs. Must be forward asymmetrical light distribution. Luminaire made of pressure die cast aluminium alloy of high corrosion resistance and non corrosive A2 stainless steel fasteners. ABS plastic installation housing for preparing the recess opening in wall / stairs. Clear acrylic diffuser. Single cable entrance via M10 cable gland. Protection class at least IP65 or higher. Mechanical resistance IK09. Pure polyester powder coated graphite grey / anthracite grey / jet black should be available in different colour temperature 3000K / 4000K / 5700K, Colour rendering index (CRI)>80. SDCM-3 MacAdam. LED module with expected service life of at least 60,000 operating hours. Prewired with LED driver and suitable for operating on 240V, 50Hz single phase ac supply. Luminaire installation in a recessed opening cut-out dimension : C.O.D : 70mm length x 83mm width x 124mm height. Make should be as per KL-2761/ Ligman/ Unilamp. CE & BIS Certified. 195 Supply and Installation of Mini Wall Grazer upto 30W K-Lite compact and minimilist linear surface mounted designed for wall wash effect. Luminaire made of extruded aluminium alloy (grade 6063) of high corrosion resistance with translucent end caps. Diffuser Material of Clear PMMA extruded lens. Protection class IP44 and mechanical resistance IK07. Luminaire should be Powder coated white / grey. Available colour temperature 2700K / 3000K / 4000K / 5700K, Beam Angle should be 30°. 60°. Colour rendering index (CRI)>80. SDCM ≤ 3 MacAdam. K-Lite LED module with expected service life of at least 60,000 operating hours. Make should be as per KL-2830/ Ligman/ Unilamp. Prewired with LED driver and suitable for operating on 240V, 50Hz single phase ac supply. Driver efficiency >85%, Power factor >0.95, THD <10%, Surge protection upto 3KV. Luminaire dimension : 1520mm length x 21mm width x 26mm height. CE & BIS Certified. 196 Supply and Installation of track lightofDie Cast Aluminium & Plastic with translucent Diffuser Material of Clear PMMA extruded lens.of size 2.5 x 5.0 x 17.2 cm / 14.5 x 6.0 x 20.0 cm / 18.0 x 8.0 x 21.0 cm Luminaire should be with Standard suspension kit of 1M. Protection class IP20 . The driver should be inbuilt with the luminaire. Luminaire should be Powder coated white / grey. High efficacy leading to energy conservation.Available colour temperature 2700K / 3000K / 4000K / 5700K, Beam Angle should be 120° for uniform lighting effect. Colour rendering index (CRI)>80. SDCM ≤ 3 MacAdam. LED module with expected service life of at least 60,000 operating hours. Make should be as per Tisva/ Ligman/ Unilamp. Prewired with LED driver and suitable for operating on 220 V AC – 240 V AC / 50 Hz single phase ac supply. Driver efficiency >85%, Power factor >0.95, THD <10%, Surge protection upto 3KV. Luminaire dimension : Ø900mm dia and 25mm height. CE & BIS Certified. 197 Supply and Installation of track accessories of length 2M of Die Cast Aluminium & Plastic with translucent Diffuser Material of Clear PMMA extruded lens.of size 2.5 x 5.0 x 17.2 cm / 14.5 x 6.0 x 20.0 cm / 18.0 x 8.0 x 21.0 cm Luminaire should be with Standard suspension kit of 1M. Protection class IP20 . Extruded aluminium tracks with full set of accesories for creative, flexible, reliable and precise installation. The driver should be inbuilt with the luminaire. Luminaire should be Powder coated white / grey. Make should be as per Tisva/ Ligman/ Unilamp. Prewired with LED driver and suitable for operating on 220 V AC – 240 V AC / 50 Hz single phase ac supply. Driver efficiency >85%, Power factor >0.95, THD <10%, Surge protection upto 3KV. Luminaire dimension : Ø900mm dia and 25mm height. CE & BIS Certified.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Uttar Pradesh View Result →
18.
Housing Urban and Rular Development #9465186 Technical Bid
Construction Of Shopping Complex Siya Complex In Rajpura Awasiy Yojna Phase 2 - Laying and Jointing PVC Pipe. Heading 2 Excavation in foundation in ordinary soil lift up to 1.50 m and lead up to 30 m complete in all respect. 3 Add for every additional 30m lead or for addition lead 1.50 m 4 Add for every additional 30m lead or for addition lead 1.50 m 5 sand filling in plinth complete in all respect. 6 Cement Concrete in 1:4:8 cement c sand and4cm gauge approved stone ballast complete in all respect. 7 R.C.C work with 1:1.5:3 cement csand and 20 mm dala stone grite complete in all respect. 8 R.C.C work with 1:1.5:3 cement csand and 20 mm dala stone grite complete in all respect. But R.C.C T beam collumn slab 9 F.F 10 S.F 11 T.F 12 R.C.C work with 1:2:4 cement csand and 20 mm dala stone grite complete in all respect. 13 F.F 14 S.F 15 T.F 16 R.C.C LINTOL 17 R.C.C work with 1:1.5:3 cement csand and 20 mm dala stone grite 40 mm thickcomplete in all respect. 18 M-150 brick work in 1:4 cement and csand complet in all respect. For half brick masonary 19 M-150 brick work in 1:4 cement and csand complet in all respect. HALF brick masonary 20 G.F 21 F.F 22 S.F 23 T.F 24 TARRACE FLOOR 25 M-150 brick work in 1:4 cement and csand complet in all respect.brick masonary 26 F.F 27 S.F 28 T.F 29 Providing and fixing ISI marked flush door shutters confirming to IS:2202 (Part 1)non decorative type core of block board 35mm thick including ISI marked Stainless steel butt hinges with necessary screws. 30 Extra for providing lipping with 2nd class tak wood battens 25mm mion all edges of flunium depth of flush door shutter 31 Providingand fixing aluminium sliding door bots ISI marked anodise not less than grade AC10 tranparent or dyed to required colour or shade with nuts and screws etc. for 0.90 m to 1.00 m wide 32 250x16mm 33 Providingand fixing aluminium sliding door bots ISI marked anodise not less than grade AC10 tranparent or dyed to required colour or shade with nuts and screws etc. for 300m m x 10 mm wide 34 200x10mm at centre below handle from inside 35 Providing and fixing of aluminium handles ISI marked anodised125 mm 36 mild steel or iron work in heavy sizes such as trusses builts up gates record racks roof work gates etc complete In all respect. 37 Mild steel or iron in plain work such as in reinforcement cement concrete or reinforcement brick work complete in all respect. 38 Providing and fixing in position sollapsible steel shutterwith vertical channels 20x 10 x 2mm ( 3/4 x 3/8 x 1/12) and braced with flat iron diagonals 20 x 5mm ( 3/4 x 3/16) size with top and bottom rails of T iron 40 x 40 x 6mm ( 1 1/2 x 1 1/2 x 1/4) with 38mm dia steel pulleys with bolts, nuts, locking 39 Supply and fixing of Rolling shutters ofapproved design made of 80 x 125mm (3 x 18 gauge) cold rolled ms lath inter locked throughout their entire length and jointed together at the end by end locks and mounted on specially designed pipe shaft with brackets , side guides and arrangements for inside and outside poking complete in all respect. 40 Providing and fixing MS Tubular frames for doors, windows, ventilatorsand cupboards with rectangular. L typesections, made of 1.60mm thick MS sheetjoints mitred, welded and grinded finish,with profiles of required size including (total 50 door chaukhats at an averageweight of 30 kg per chaukhat)= 1500 kg Fixing with 15 x 3mm lugs 10cm long embedded in cement concrete block 15 x 10 x 10 cm of CC 1:3:6 (1 cement :3 coarse sand :6 graded stone aggregate 20mm nominal size) 41 Providing and laying water proofing treatmentin sunken portion of WCs, bathroom etc by applying cement slurry mixed with water proofing cement compound consisting of be allowed to air cure for 4 hours followedapplying a. First layer of slurry of cement @ 0.488 kg/ sqm mixed with water proofing compound @ 0.253 kg/ sqm . This layer shall be allowed to air cure for 4 hoursb . Second layer of slurry of cement @ 0.242 kg/ sqm mixed with water proofing compound @ 0.126 kg/ sqm. This layer will be allowed to air cure for 4 hours followed 42 12mm thick plaster with cement mortar consisting of 1 part cement and 4 parts of approved coarse sand (of 1.25 fineness modulous). Minimum thickness to be notess than 10m. Including supply of all 43 12 mm thick plaster with cement mortarconsisting of 1 part cement and 3 part of approved coarse sand.Minimum thickness not to be less than 10mm. Including supply of all materials, labour and T and P etc. 44 Add for extra labour and material for plaster over rough face of one brick wall 45 Making grooves 10 to 12mm wide x 8mmdeep in plaster of the wall or in ceiling vertically or horizontally as required. 46 20mm cement plaster in two coats(for basement wall) backing coat of 17mm and finishing coat of 3mm thick of neat cement or cement and marble dust in ratio 3:1 on rough side of single or half brickwall for interior plastering upto floor two level including arises, internal rounded anglenot exceeding 80mm in girth and finish edeven and smooth.1cement : 3 coarse sand 47 Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer) of approved make , in all colours, shades white cement mixed with pigment of except burgundy, bottle green, black of any size as approved by Engineer in charge , in skirting, risers of steps and dados over 12mm thick bed of ement mortar 1:3 ( 1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in complete in all respect. 48 Providing and laying rectified Glazed ceramic floor tiles of size 300 x 300 mm or more (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours white, ivory, grey fume red brown, laid on 20mm thick cement mortar 1:4 ( 1 cement : 4 coarse sand) including grouting the joints with white cement and matching pigments etc. complete. 49 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622 of approved make, in all colours and shades, laid on 20mm thick cementmortar 1:4 ( 1 cement : 4 coarse sand) size of tile 600 x 600 mm 50 Providing and laying Vitrified tiles indifferent sizes, (thickness to be specified by manufacturer) with water absorption less than 0.08%and conforming to Is:15622 of approved make in all colours and shade , in skirting, risers of steps,over 12mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand) joiinting with grey cement slurry @ 3.3kg/ sqm including 51 Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per architectural drawings with 18mm thick stone slab over 20mm (average) thick base of cement mortar 1:4 ( 1 cement : 4 coarse sand) laid and jointed with cement slurry 52 (As per above except colour ) Polished Granite stone slab of all colour and texture except black, cherry/ ruby red 53 Providing and fixing stainless steel (grade 304) railing made of hollow tubes, channels plates etc. including welding, grinding, buffing, polishing, and making curvature wherever required, and fitting the same woth necessary stainless steel nuts and bolts complete i/c fixing the railing with necessaryaccessories and stainless steel dash 54 Chequered precast cement concrete tiles 22mm thick in footpath and courtyard with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete on 20mm thick bed of cement mortar 1:4 ( 1 cement : 4 coarse sand) 55 Providing and applying white cement based putty of average thickness of 1mm of approved brand and manufacturer over the plastered wall surface to prepare the surface even and smooth complete. 56 One priming coat of cement primer and one coat oil distemper on new work including supply of all materials, labour and tools and plants etc. required for proper ompletion of the work. 57 As in item 33 above but for every coat after the first coat. 58 Finishing walls with Premium Acrylic Smooth exterior paint with silicone additives of required shade New work (two or more coats applied @ 1.43 litres/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm) 59 Painting roofs or other iron work in large areas with one coat of ready mixed paint primer and one coat of approved paint (British, Anisole or equivalent) including supply of all materials, labour and T and P etc. required for proper completion of the work. Paint to be used should confirm to 60 Painting with valsper or other approved high grade enamel complete one coat over previously painted surface including supply of all materials, labour and tools and plants etc. required for proper completion of the work. Enamel to be used should confirm to 61 Painting or varnishing new iron work in small areas or new wood with one coat (upto one sqm) of ready mixed priming paint and one coat of approved superior quality ready mix paint (2nd quality synthetic enamel paint of approved brand such as British paint, Shalimar, Asian or equivalent as approved by E/I) or varnish including supply of all materials, labour, 62 As in item no. 38 above but for every coat after the first coat 63 Providing and fixng factory made UPVC wihite colour fixed glazed windows/ ventilators comprising of UPVC multi chambered frame and mullion (wherever required) extruded profiles duly reinforced with1.60 + /-0.2mm thick galvanized mild steel section made from roll forming process of required length shape and size according to UPVC profile upvc extruded glazing beads of appropriatedimension, EPDM gasket GI fastners 100 x 8mm size for fixingframe to finished hardware and drainage of water etc After fixing the gap between frame andadjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality all complete as per approveddrawing and direction of Engineer in charge (single/ double glass panes and silicon sealant shall be paid seprarately) Fixed window / ventilator made of (small series) frame 47 x 50mm and mullion 47 x 68mm both having wall thickness of 1.9 + / - 0.2mm and single glazing bead of appropriate dimension 64 Providing and fixing factory made upvc white colour sliding glazed window upto 1.50m in height dimensions comprising of upvc multi chambered frame with in built roller track and sash extruded profiles duly reinforced with 1.60 + /- 0.2mm thick galvanized mild steel section made from roll forming process of required length shape and size according to upvc profile. appropriate dimension of upvc extruded glazing beads and upvc extruded interlocksepdm gasket , wool pile, zinc alloy white powder coated touch locks with hook, sinc alloy body with single nylon rollers (weight bearing capacity of 40kg) gi fastners, 100 x 8mm 65 (rest as per above but for larger area) Two track two panels sliding window made of (big series) frame 67 x 50mm and sash 46 x 62mm both having wall thickness of 2.3 + / - 0.2mm and single glazing bead/ double glazing bead of appropriate dimension (area of window above 1.75 sqm upto 2.50 sqm) 66 Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows an clerestorey windows (area of opening for panel inserts excluding portion inside grooves or rebates to be measured) Panelling for panelled or panelled and glazed shutters 25mm to 40mm thick.Float glass panels 5mm thick glass panels (weight not less than 12.50 kg/ sqm) 67 Providing and fixing stainless steel (ss 304) grade friction hinges to the side/ top hung UPVC windows of approved quality with necessary stainless steel screws etc as per directions of Engineer in charge. 200 x 19 x 1.9mm 68 Providing and fixing casement handle made of zinc alloyed (white powder coated) for upvc casement window with necessary screws etc.complete. 69 Filling the gap in between upvc frame and adjacent rcc/ brick/ stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of engineer in charge complete Upto 5mm depth and 5mm width. 70 Aluminium framing for Aluminium Composite Material Cladding all complete.Providing and supplying aluminium extruded tubular and other aluminiuim sections as per the architectural drawings and approved shop drawings , the aluminium quality as per grade 6063 Y5 or T6 as per BS 1474, including super durable powder coating of 60- 80 microns conforming to AAMA2604 of required colour and shade as approved by the Engineer in charge (The item includes cost of material such as cleats, sleeves, 71 Designing, fabricating, testing , installing nd fixing in position Curtain wall with Aluminium Composite Panel cladding with open grooves for linear as well as curvilinear portions of the building, for all heights and all levels including.Structural analysis and design and preparation of shop drawings for pressure equalisation or rain screen principle as equired, proper drainage of water to make it watertight including checking of all the structural and functional design. 72 Providing and laying integral cement based waterproofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc. consisting of the following operations 73 CONSTRUCTION OF R.C.C TANK 74 Earth work in exacavation in trenches for foundations and for pipes cables etc. in ordinary soil(loam clay or sand) including lift upto 1.5 m and dressing of sides and ramming of bottom sand disposal of surplus excavated earth as directed by the Engineer i/c with in a lead of 30m. 75 In all kind of soil upto 1.5m to 3.0m. depth 76 In all kind of soil upto 3.0m to 4.5m. Depth 77 In all kind of soil upto 4.5 m to 6.0m. Depth 78 Providing and laying in cement concrete 1:4:8 (1 cement :2 coarse sand :4 graded Stone asize) and curing complete,including cost of form- work,in foundation and floors. 79 Reinforcement cement concrete work in RCC culvert slab with 1:2:4 (1 cement : 1.5 coarse sand and 3 gradded stone aggregate of 20 mm nominal size) excluding centering and shuttering and reinforcement. 80 Providing & Fixing Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level. 81 SUB HEAD-I-SANITARY INSTALLATIONS 82 Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required :W.C. pan with ISI marked white solid plastic seat and lid 83 Providing and fixing white vitreous chinaextended wall mounting type water closet of size 780x370x690 mm of approved shape including providing & fixing white viterous china cistern with dual flush fittings of flushing capacity 3 litre / 6 litre ( adjustable to 4 litre / 8 litres ) includung seat cover & cistern fittings nuts , bolts and gaskets etc complete. C.P. brass 84 Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge. 85 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm witha single 15 mm C.P. brass pillar tap 86 Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. 87 Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms. 88 Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms. 89 Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. 90 Providing and fixing C.P.brass angle valve for basin mixer and geyser points of approved quality conforming to IS 8931 (including angle valve for WC flushing cistern, jet & kitchen sink) 15 mm nominal bore 91 Providing and fixing uplasticised PVC connection pipe with brass unions 15 mm nominal bore 92 Providing and fixing Stainless Steel AISI 304 (18/8) kitchen sink as per IS: 13983 with C.I. brackets and stainless steel plug 40 mm, including painting offittings and brackets,cuttingandmakinggoodthe walls wherever required 510x1040 mm bowl depth 200 mm 93 Providing & fixing PVC waste pipe for sink including PVC waste fittings Complete32mm Dia 94 Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : 15mm nominal bore 95 Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.15mm nominal bore 96 Providing and fixing white vitreous china battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre & post flushing with water (250 ml & 500 ml consumption), having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of Engineer-in-charge. 97 Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as perdirection of Engineer-in-charge and finished smooth. Granite Stone of approved shade 98 SUB HEAD-II-WATER SUPPLY 99 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. For Internal Toilet 15 mm nominal outer dia Pipes 100 20 mm nominal outer dia Pipes 101 25 mm nominal outer dia Pipes 102 32 mm nominal outer dia Pipes 103 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall20 mm nominal bore 104 25 mm nominal bore 105 32 mm nominal bore 106 Providing and fixing GI pipes complete with GI fittings and clamps, i/c cutting and making good the walls etc. Internal work - Exposed on Wall Terrace loop & Tank Filling Pipe 50 mm bore 107 65 mm nominal bore (i/c two coat of synthetic enamel paint) 108 Supply, fixing, testing and commissioning of following Electrical Actuator Single Phase 220V AC Operated Wafer Type Butterfly Valve - IP65CB - 230VAC, as per specifications:- Lehry Make Automatic OHT Level Control System Consist of Following Items 1) LEHRY Make On-Off Type Electrical Actuator Single Phase 220V AC Operated Wafer Type Butterfly Valve with CI Body & SS Disc 2) Level Float Switch- 5M 3) Control Box (a) IP 65 Finishing(250 x 160 x 115)mm (b) LED Lamps: Tank FULL, Tank EMPTY, Power (c) Power supply toggle switch (d) Accepts 230V Single Phase power supply and provides 24VAC to float switch and 230VAC to valve coil. (e) Accepts NO/NC feedback from float switch. 65mm 109 Painting G.I. pipes and fittings with synthetic enamel white paint with two coats over a ready mixed priming coat, both of approved quality for new work50mm diameter pipe 110 Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete : 25 to 40 mm nominal bore 111 50 to 80 mm nominal bore 112 Providing and fixing brass stop cock of approved quality : For Internal Toilet 20 mm nominal bore 113 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :For vertical pipe connection with terrace ringmain 20 mm nominal bore 114 25 mm nominal bore 115 32 mm nominal bore 116 50 mm nominal bore 117 65 mm nominal bore 118 Providing and fixing MS pipe puddle flanges of required size with 600mm long with 6mm thick MS plate of size 300mm x 300mmof suitable size properly fixed in RCC walls of water tanks, including necessary welding complete in all respect as per details shown on darwings and directions of Engineeer-in-charge for water tanks. 25mm dia. 119 50mm dia. 120 65mm dia. 121 80 mm dia. 122 100mm dia. 123 150mm dia. 124 200mm dia. 125 SUB HEAD : III - ROOFING 126 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS :13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 110 mm dia (for rain water) 127 Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A,including jointingwithsealringconformingtoIS: 5382, leaving 10 mm gap for thermal expansion. Single Push Fit Coupler 110 mm dia 128 Single tee with door 110x110x110 mm 129 Plain bend 87.5 deg 10 mm dia 130 Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 110 mm dia 131 Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. 132 SUB HEAD : IV - INTERNAL DRAINAGE 133 Providing, fixing, jointing and testing,uPVCSWR pipes, - type B conforming to IS : 13592to wall, ceiling and floor, approved quality, complete, for soil, waste & rain water drain including pushfit jointing with seal ring. (i) Single socketed pipes. Internal Toilet (Soil & Waste Pipe) 75 MM 134 100mm dia. 135 Exposed on Wall (Soil & Waste Pipe) 110 mm 136 Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC pipes including jointing with seal ring leaving 10 mm gap for thermal expansion. Bend without door (87.5°) 110mm bend 137 Bend without door (45°) 138 100mm 139 Y Fitting without door 100mm 140 75 mm 141 Reduced Y Fitting without door 100mm x 75mm 142 Single Tee without door 100mm 143 75 mm 144 Single Tee with door 100mm 145 Reduced Tee with door 110mm x 75mm 146 Coupler 110mm 147 Clean Out Plug (COP) 110 mm 148 75 mm 149 Vent Cowl 110 mm 150 Providing, fixing, jointing and testing, unplasticized PVC pipes - 10 kg/cm2 confirming to IS : 4985 to wall, ceiling and floor, approved quality, complete, for waste water drain including jointing with rubbering/solvent/solution and airtight joints, etc For Wash basin & Urinal 50m dia pipe 151 32 mm dia pipe 152 Elbow (90°) 50mm 153 32mm 154 Elbow (45°) 50 mm 155 32 mm 156 T fitting50mm 157 32 mm 158 Providing, fixing, jointing and testing ,ofPVC Multi Floor Trap without jali ofminimum 50 mm water seal, making necessarycuttingin slabor floors and making goodincluding supports with cement concrete 1:3:6complete as approved by Engineer-in-Charge. 110mm x 75mm x 50mm/40mm (Toilet) 159 Providing, fixing, jointing and testing , ofPVC NahaniTrap without jali ofminimum 50 mm water seal, making necessarycuttingin slabor floors and making goodincluding supports with cement concrete 1:3:6complete as approved by Engineer-in-Charge. 110mm x 75mm (Toilet) 160 110mm x 75mm (Kitchen) 161 Providing and fixing PTMT grating of approved quality and colour.Rectangular type with openable circular lid Rectangular type with openable circular lid 162 Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design : 150 x 100mm size P-typeWith common burnt clay F.P.S. (non modular) bricks of class designation 7.5 163 Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete: 100 mm diameter 164 Excavating trenches of required width for pipes cables etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m ncluding getting out the excavated soil , and then returning the soil as required , in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed , within a lead of 50 m. All kind of soil Pipes, cables etc. exceeding 80 mm dia . But not exceeding 300mm dia. 165 Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W.pipes including bed concrete as per standard design: 100mm dia SWpipe 166 COST OF SEWERAGE WORKS 167 Excavating trenches in all kinds ofsoil of required width for pipes. including excavation for sockets and dressing of sides, ramming of bottoms, including getting out the excavated soil & then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc & disposing of surplus excavated soil as directed within a lead of 50m.up to 1.50 m depth Pipes 80 mm to 300 mmdiameter 168 Opentimbering in trenches including shuttering and shoring complete. (Measurement to be taken of the face area timbered) Depth not exceeding 1.5 meter 169 Providing and laying NonpressureNP 2 class (light duty) RCC pipe with collars jointed withstiffmixtureofcement mortar in the proportion of 1:2 (1cement : 2 finesand ) includingtestingof joints etc. complete. 150 mm.dia. RCCPipes 170 Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand : 10 graded stone aggregate 40mm nominal size) upto the haunches of pipes including bed concrete as per standard design 150 mm.dia. RCCPipes 171 Inside size 90x80cms and 45cms deep including CI cover with frame (light duty) 455x610mm internal diamensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15kg). (i) For Sewer Line 172 Extra for depth for manholes: Size 90x80cm with With common burnt clay FPS (non modular) bricks of class designation 7.5 173 Inside size 90x120cms and 90cms deep including CI cover with frame (medium duty) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg (weight of cover 58 kg and weight of frame 58kg). With common burnt clay FPS (non modular) bricks of class designation 75 (i) For Sewer Line 174 Extra for depth for manholes: Size 90x120cm with With common burnt clay FPS (non modular) bricks of class designation 7.5 175 Providing orange colour safety footrests of minimum 6 mm thick plastic encapsulated as per IS:10910 on 12 mm dia steel bar conforming to IS:1786 having minimum cross section as 23 mm x 25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm thread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufactures permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design. 176 COST OF EXTERNAL WATER SUPPLY WORKS 177 Providing & fixing G.I. pipes complete with G.I. fittings includingtenching and refilling etc. (external work) 65mm nominal bore. 178 Supplying and fixing of specials for pressure pipe 10 % 179 Providing and fixing gate valve (with cap complete with bolts, nuts, rubber insertion etc. 65 mm nominal bore 180 Constructing masonry Chamber 90X90X100 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand ) for sluice valve, with C.I. surface box 100mm, top diameter, 160 mm bottom diameter and 180mm deep (inside) with chained lid and RCC top slab 1:2:4 mix ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 (1 cement :5 fine sand : 10 graded stone aggregate 40mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand ) 12 mm thick finished with a floating coat of neat cement complete as per standard design : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 181 Supply, Installation, testing & commissioning of Vertical in line pumping setcomplete. The rate shall include the cost of electrical panel and piping work complete Domestic Water Supply pumps : Capacity/Flow Rate - 12.5 m3/hr Head- 45 mLocation-1 set in UGT (1 set = 2nos(1W+1S)) 182 Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required. 183 Supply, fixing, testing and commissioning of Level Float Switch, for dry run protection of pump as per specifications:- Size 5 Mtr, Item Code (LIV-LFV-RED- MTR)(location : UG TANK) 184 RAIN WATER HARVESTING 185 Earth work in exacavation in trenches for foundations and for pipes cables etc. in ordinary soil(loam clay or sand) including lift upto 1.5 m and dressing of sides and ramming of bottom sand disposal of surplus excavated earth as directed by the Engineer i/c with in a lead of 30m. In all kind of soil upto 1.5m depth 186 In all kind of soil upto 1.5m to 3.0m. depth 187 In all kind of soil upto 3.0m to 4.5m. Depth 188 In all kind of soil upto 4.5 m to 6.0m. Depth 189 Providing and laying in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded Stone aggregate 20 mm nominal size) and curing complete,including cost of form- work,in foundation and floors. 190 Class M-150 brick work in 1:4 cement coarse sand mortar infoundation & plinth including supply of all materials, labour, tools and plants etc. required for proper completion of the work. 191 Reinforcement cement concrete work in RCC culvert slab with 1:1.5:3 (1 cement : 1.5 coarse sand and 3 gradded stone aggregate of 20 mm nominal size) excluding centering and shuttering and reinforcement. 192 Providing & Fixing Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level. 193 12mm cement plaster on rough side of single or half brick wall mix 1:3 (1 cement : 3 Coarse sand) 194 Providing M.S. foot rests including fixing in manoholes with 20x20x10 cm cement concrete blocks 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) as per standard design: With 20x20mm square bar 195 Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality. M.D. -10- Circular shape 500mm internal diameter 196 Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, beyond 90 metre & upto 150 metre depth below ground level. Drilling of 300mm dia bore hole manually. 197 Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 198 Supplying, filling, spreading & leveling stone boulders of size range5 cm to 20 cm, in recharge pit, in the required thickness, for all leads& lifts, all complete as per direction of Engineer-in-charge. 199 Supplying, filling, spreading & leveling gravels of size range 5 mm to10 mm, in the recharge pit, over the existing layer of boulders, inrequired thickness, for all leads & lifts, all complete as per directionof Engineer-in-charge. 200 Gravel packing in tubewell construction in accordance with IS: 4097,including providing gravel fine/ medium/ coarse, in required grading& sizes as per actual requirement, all complete as per direction ofEngineer-in-charge. 201 DESILTING CHAMBER 202 Earth work in exacavation in trenches for foundations and for pipes cables etc. in ordinary soil(loam clay or sand) including lift upto 1.5 m and dressing of sides and ramming of bottom sand disposal of surplus excavated earth as directed by the Engineer i/c with in a lead of 50m. 203 In all kind of soil upto 1.5m to 3.0m. Depth 204 Providing and laying in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded Stone aggregate 20 mm nominal size) and curing complete,including cost of form- work,in foundation and floors. 205 Class M-150 brick work in 1:4 cement coarse sand mortar infoundation & plinth including supply of all materials, labour, tools and plants etc. required for proper completion of the work. 206 Reinforcement cement concrete work in RCC culvert slab with 1:1.5:3 (1 cement : 1.5 coarse sand and 3 gradded stone aggregate of 20 mm nominal size) excluding centering and shuttering and reinforcement. 207 Providing & Fixing Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level. 208 12mm cement plaster on rough side of single or half brick wall mix 1:3 (1 cement : 3 Coarse sand) 209 Providing M.S. foot rests including fixing in manoholes with 20x20x10 cm cement concrete blocks 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) as per standard design: With 20x20mm square bar 210 Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality. M.D. -10- Circular shape 500mm internal diameter 211 DRAINAGE NETWORK 212 Excavating trenches in all kinds ofsoil of required width for pipes. including excavation for sockets and dressing of sides, ramming of bottoms, including getting out the excavated soil & then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc & disposing of surplus excavated soil as directed within a lead of 50m. Pipes 80 mm to 300 mmdiameter 213 Providing and laying NonpressureNP 2 class (light duty) RCC pipe with collars jointed withstiffmixtureofcement mortar in the proportion of 1:2 (1cement : 2 finesand ) includingtestingof joints etc. complete. 150 mm.dia. RCCPipes 214 Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand : 10 graded stone aggregate 40mm nominal size) upto the haunches of pipes including bed concrete as per standard design 215 a) Inside size 60x60 cm & 90 cm deep including C.I. cover with frame (light duty) total wt. of cover & frame to be not less than 38 Kg (wt. of cover 23 Kg & wt. of frame 15 Kg. 216 Supply, installing, testing and commissioning of non clog submersible type drainage / dewatering pumpset Product Type: SUBMERSIBLE DRAINAGE PUMPProduct ConfigurationPump Classification: Standard PumpComponent MaterialsVolute Material: Cast Iron FG 260Impeller Material: Cast Iron FG 260Shaft Material: S.S AISI 410Seal Material: Carbon/Ceramic/NBR/S.S 304Motor SpecificationsPhase: 3Voltage: 380-415VCable Length: Standard - 5 metresCable Length: Additional - 0 metres: 0Pipework ConnectionFloat Switch: With Float SwitchSolids Diameter LimitMaximum Solids Diameter: 10 mm Flow Rate = 205 LPM Each Pump Head = 9m Each Pump Set Detail = 1W+1S ( 1No. for UGT & 1 No. in basement) 217 Constructing brick masonary open surface drain with bricks of class designation 75 in cement mortar 1:4 (1 cement : 4 fine sand) including earth excavation, 10cm thick bed concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size) and 25mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 12.5mm nominal size) for filling haunches including 12mm cement plaster 1:4 (1 cement : 4 coarse sand ) with a floating coat of neat cement inside the drain, its top and exposed side including disposal of surplus earth complete as per standard design: 218 SEPTIC TANK & SOAK PIT 219 Earth work in excavation over areas including disposal of excavated earth, lead upto 50m, disposed earth to be levelled and neatly dressed. In all kind of soil upto 1.5m depth 220 n all kind of soil upto 1.5m to 3.0m. Depth 221 In all kind of soil upto 3.0m to 4.5m. Depth 222 Providing and laying of cement concrete in base excluding the cost of centring and shuttering by 1:2:4 (1 cement : 2 coarse sand : 4 gradded stone aggregae 20mm nominal size) 223 Brick work with brick of class designation 150 in foundation and plinth in cement mortar (1 cement : 4 coarse sand) 224 Reinforcement cement concrete work in RCC culvert slab with 1:1.5:3 (1 cement : 1.5 coarse sand and 3 gradded stone aggregate of 20 mm nominal size) excluding centering and shuttering and reinforcement. 225 P/F Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor 226 12mm cement plaster on rough side of mix 1:3 (1 cement : 3 coarse sand) 227 Providing M.S. foot rest including fixing with 20x20x10 cm. cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 gradded aggregate of nominal size 20mm ) as per standard design with 20x20mm sq bars. 228 Providing and fixing C.I. tee at the inlet and outlet of septic tank. 229 Providing & fixing 75mm dia vent pipes. 230 Providing & fixing of 75mm dia cast iron terminal guard. 231 Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality. M.D. -10- Circular shape 500mm internal diameter 232 M.D. -2.5- Circular shape 450mm internal diameter 233 Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks of class designation 75 and S.W. drain pipe 100 mm diameter, 1.8m long complete as per standard design. 234 CONSTRUCTIONOFTUBEWELL 235 Drilling of 200 mm dia bore hole. 236 Supply of 125 mm dia MSpipe as per IS1239 237 Supply of 125 mm dia slotted MSpipe 238 Supply and fixing of nylon jali around the slotted pipes 239 Providing and packing of coarse sand / pea gravel around the pipe (7.44 Cum) 240 Transport of boring tools other required equipements and 241 Supply of submersible pump of make KSB (Cora) for 200 lit/min discharge at 50 meter head with control panel, support wire etc 242 Providing/inst. Of copper multistand PVC insulated FR cable suitable for submersible pump. (from Starter panel to submersible pump) 3 core copper cable 243 Providing and fixing 65 mm dia. G.I. pipe complete with fittings and clamps including cutting and making good the wall etc. (from submersible pump to ground level) 244 Providing and fixing 65 mm dia. brass gate valve with CI wheel of approved quality. 245 Lowering of 125 mm dia MS pipe in bore hole including cutting,jointing etc complete. 246 Supply and fixing of tube well accessories i.e. well cap, clips, clamps, etc. to complete the job in all respect. 247 Fixing, testing and commissioning for erection and lowering of submersible pump, 65 mm dia GI column pipe, 3 core submersible copper cable upto the control panel, supporting clamps, cable clips, pressure gauge, connection line and all other accessories required for the proper completion of the 248 Testing and development of tube well.
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 5
Uttar Pradesh View Result →
19.
Housing Urban and Rular Development #9456641 Technical Bid
Tender For Balance Work Tourist Facilitation Center At Lalapur District Chitrakoot (U.P.), 1 Balance Work Tourist Facilitation center at LalapurDistrict Chitrakoot (U.P.) 2 R.C.C. (M-20) work with cement approved coarse sand and 20 mm. guage approved stone grit im the proportion of 1:1.5:3 in lintels of doors and windows excluding supply of reinforcement and its fixing and binding the same with 24 BWG binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour, tools and plants etc. required for proper completion of the works. 3 First Floor 4 Second Floor 5 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete .R.C.C. columns(Concrete ofM-25 grade with minimum cement content of 330 kg /cum ) R.C.C. FOOTING 6 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete .R.C.C. columns(Concrete ofM-25 grade with minimum cement content of 330 kg /cum ) 7 First Floor 8 Second Floor 9 As in item no. 6 above but for slabs (Using 1:1.5:3 Mix concrete) [M-20] 10 First Floor 11 Second Floor 12 As in item 6 but for thelighterbeams i.e. having spans upto 6 m. (Using 1:1.5:3 Mix concrete) [M-20] 13 First Floor 14 Second Floor 15 Same as in item no. 11 above but in super-structure above plinth level including necessary cutting and moulding of brick work as required & also including honey combed brick work in thickness of wall more than one brick and for extra labour to above items. 16 First Floor 17 Second Floor 18 Same as in item no. 12 but in1:4 cement and coarse sand mortar in superstructure for wall thickness 12 cms & below brick work. Second Floor 19 P/F Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level. 20 Above Plinth Lvl. 21 Second Floor 22 15mm thick cement plaster on rough side of single or half brick wall of mix in 1:4 (cement & coarse sand) in plinth. 23 12mm cement plaster in single coat on fair side of single or half brick wall for exterior plastering up to floor two level including internal rounded angles chambers, and/or roundedangles not exceeding 80mm in girth and finished even and smooth. (1) 1 cement : 6 coarse sand 24 Ground Floor 25 First Floor 26 Second Floor 27 15 mm cement plaster in single coat on rough side of single or half brick wall for interior plastering up to floor two level including internal rounded angles not exceeding 80 mm in girth and finshed even and smooth. (1) 1 cement : 6 sand 28 Ground Floor 29 First Floor 30 Second Floor 31 Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections. 32 Ground & First Floor 33 Second Floor 34 Cement concrete flooring 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 12-20mm nominal size laid in one layer neat cement (25 mm thick floor). 35 Providing and laying 8 to 10 mm thick ivory or light shade vitrified tiles of 600 x 600 mm size in flooring or skirting laid with cement mortar 1:3 (1 cement : 3 coarse sand) finished with cement slurry & with pigment grouting & polishing complete including supply of all materials, labour, T & P etc. required for proper completion the work excluding base concrete. 36 Ground Floor 37 First Floor 38 Second Floor 39 Providing and laying Polished Granite stone flooring in required designand patterns, in linear as well as curvilinear portions of the building allcomplete as per the architectural drawings with 18 mm thick stone slabover 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4coarse sand) laid and jointed with cement slurry and pointing with whitecement slurry admixed with pigment of matching shade includingrubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. 11.56.1 Polished Granite stone slab colour of Black, Cherry/Ruby Red or equivalent 40 Providing and laying Polished Granite stone flooring in required designand patterns, in linear as well as curvilinear portions of the building allcomplete as per the architectural drawings with 18 mm thick stone slabover 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4coarse sand) laid and jointed with cement slurry and pointing with whitecement slurry admixed with pigment of matching shade includingrubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. 11.56.1 Polished Granite stone slab colour of Black, Cherry/Ruby Red or equivalent 41 Providing and fixing Glass mossaic tiles on finished plain wall surface of size 20 mm x 20 mm x 4 mm in all colour, design , fixing in customize design as per direction of Engineer-in- Charge. The glass mosaic tiles to be fixed on the wall surface with the help of approved adhesive applied at the rate of 2.5 kg per sqm and grouting of the same. The rate is inclusive of all operation, material and required pattern approved by Engineer-in-Charge: 42 Supply and fixing 6 mm (1/4) thick China glazed tiles in flooring or in skirting or dado laid with 1:3 cement and approved coarse sand mortar finished with white cement slurry jointing and polishing complete including supply of all materials, labour and tool sand plants etc. required for proper completion of the work. 43 Ground & First Floor 44 Second Floor 45 Providing and laying brick coba 100 mm thick laid with M-150 class brick bat coba 7.50cm thick with gap of 15mm to each other, over 20 mm thick base of cement mortar 1:4 cement and coarse sand mixed with water proofing compound spreading cement slurry mixed with acrelic cement concrete water proofing compound filled gaps of coba & top of coba mortar mixed with water proofing compound in 1:4 cement and coarse sand mortar finised smooth & top mashed false square 30 cm x 30 cm and side wall parapet shall be mono tythic plaster wall up to 30 cm higher and junction and corner shall be rounded by brick ballast cement and coarse sand masonany Coba with top finised plaster mixed with acetic water proofing compound @ 2% by weight & including s/o all material, labour, T& P etc complete for proper completion of work. 46 Supply & fixing of flush doors commercial quality conforming to IS : 2202 Part I (1983) including fixing of wooden cleats & stoppers & including fixing & adjustment of hinges, bolts locks, handles, springs & other fittings but excluding their supply & including painting with two coats of black Japan paint on all iron fitting. Fitting with necessary screws to be supplied departmentally. 35 mm thick. 47 Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). 48 Extra for Providing and fixing flush doors with decorative veneering instead of non decorative ISI marked flush door shutters conforming to IS: 2202 (Part I) 49 Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.10.15.1 Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) 50 Providing & fixing of door / windows grill. Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. 9.48.1 Fixed to steel windows by welding 51 Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.10.15.1 Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) Angle iron chaukhat (40x40x5) 52 Fixing of Door, windows / ventilators chaukhats in position. 53 (a) Door chaukhats 54 (b) Window chaukhats 55 (c) Ventilator chaukhats 56 Providing and fixing factory made uPVC white colour casement/casement cum fixed glazed windows comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDMgasket, stainless steel (SS 304 grade) friction hinges, zinc alloy (white powder coated) casement handles, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardwares and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately) Note: For uPVC frame, sash and mullion extruded profilesminus 5%tolerancein dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. Casement window single panel with S.S. friction hinges (300x 19 x 1.9 mm), made of (small series) frame 47 x 50 mm & sash 47 x 68 mm both having wall thickness of 1.9 ± 0.2 mm andsingle glass pane glazing beadof appropriate dimension.(Area of window upto 0.75 sqm.) 57 Providing and fixing factory made uPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardwares and drainage of water etc.After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately). Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. Three track three panels sliding window with fly proof SS wire mesh (Two nos. glazed & one no. wire mesh panels) made of (small series) frame 92 x 44 mm & sash 32 x 60 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension (Area of window upto 1.75 sqm). 58 Providing and fixing factory made door frame (single rebate) made out of single piece extruded solid PVC foam profile with homogenous fine cellular structure having smooth outer integral skin having 62 mm width & 32 mm thickness, frame will be mitred & Jointed with self driven self tapping screws of size 38 mm x 4 mm & PVC solvent cement, including fixing the frame to wall with suitable dia & length anchor fastener as per manufacturers specification and direction of Engineer-in-charge. 59 Providing and fixing factory made 30 mm thick door shutter made of solid PVC foam profile. The styles & rails shall be of size 75 mm x 30 mm having wall thickness 5 mm. The styles, top & bottom rails shall have one side wall thickness of 15 mm integrally extruded on the hinge side of the profile for better screw holding power. The styles and rails shall be reinforced with M.S. tubes of size 33 mm x 17 mmx 1 mm, painted with primer , all four corners of reinforcement to be welded or sealed. Solid PVC extruded bidding (push fit type) will be set inside the styles and the rails with a cavity, to receive single piece extruded 5mm PVC sheet as panel. The styles & rails will be mitred cut, joint with the help of PVC solvent cement & self driven self tapping screws. Single piece extruded solid PVC lock rail of size 100 mm x 30 mm with wall thickness 5 mm & 15 mm integrally extruded in the middle of the lock rail & fixed with styles with the help of PVC solvent cement & self driven self tapping screws of size 100mm x 8 mm complete as per manufacturers specifications & direction of Engg.-in-charge. Non decorative finish 60 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections & other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia & size, including necessary filling up the gaps at junctions, i.e. at top, bottom & sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engg.-in-charge. (Glazing, paneling & dash fasteners to be paid for separately) : Powder coated aluminium (minimum thickness of powder coating 50 micron) 61 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 5 mm thickness (weight not less than 12.50 kg/ sqm) 62 Providing and fixing fly proof stainless steel grade 304 wire gauge, to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.50 mm all complete. With 2nd class teak wood beading 62X19 mm 63 Polishing in high gloss/matt finish melamine clear polish on woodwork in required color/wooden shade texture with following process in the sequence as detailed below: 1. The surface to be polished is rubbed with sand paper 80/120 no.and then with sand paper of 160/180 nos.2. Applying two coats of sealer with spray gun and allowing sufficientdrying time for 1st coat and 2nd coat is allowed to dry for 8 to 12hrs.3. On drying of sealer coat, wet rubbing with emery cloth of finergrading with ample water to remove excess sealer layer andmake the surface further smooth after this wet rubbing, thensurface is applied with special grade melamine fillers to fill all the small and big holes/grooves etc. Filler coat to be allowed to dry for 4 to 6 hrs on which again a light wet rubbing is done this surface is further allowed to dry for 12 hrs. 4. On this, 1st coat of melamine polish is applied with spray gun using melamine clear polish and melamine thinner in required proportion. This 1st coat is allowed to dry for 24 hrs then this dry surface is again fine wet rubbed smooth, which is further allowed to dry for 12 hrs. The final melamine polish is applied with compressor pressure spray gun using melamine clear polish and melamine thinner mixed in required proportion complete asper direction of Engineer-in-Charge. (Final coat to be done in 1 or 2 layers without gap of time.) 64 Same as above but on new wood surface. 65 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade. New work (Two or more coats applied @ 1.43 ltr/ 10 sqm. over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm). 66 Ground Floor 67 First Floor 68 Second Floor 69 Painting with silicon & acrylic emulsion based water thinnable sealer of approved brand and manufacture on wet or patchy portion of plastered surfaces :Two coats. (For Internal wall surface & ceiling) (Asian Paint or equivalent) 70 Ground Floor 71 First Floor 72 Second Floor 73 Providing and applying white cement based putty of average thickness 2 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 74 Ground Floor 75 First Floor 76 Second Floor 77 Providing & fixing stainless steel sliding door bolts ISI marked to required colour or shade with nuts and screws etc complete.(a) 300mm x 16mm 78 P/Fixing stainless steel tower bolts ISI marked to required colour or shade with necessary screws etc. 79 (a) 250 mm x 10mm 80 (b) 200 mm x 10mm 81 Providing & fixing stainless steel handles ISI marked to required colour or shade with necessary screws etc. complete. 125 mm 82 Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete. 83 Providing and fixing aluminium tubular handle bar 32 mm outer dia, 3.0 mm thick & 2100 mm long with SS screws etc .complete as per direction of Engineer-in-Charge. Powder coated minimum thickness 50 micron aluminium tubular handle bar 84 Providing & fixing of Rolling shutters of approved design made of 80 x 125 mm (3 x 18 gauge) cold rolled MS lath interlocked throughout their entire length and jointed together at the end by end locks end mounted on specially designed pipe shaft with brackets, side guides & arrangements for inside and outside poking with push & pull operation complete but excluding the cost of top cover and spring. 85 Providing & fixing 27.5cm long wire spring grade No. 2 for rolling shutters. 86 Providing & fixing top cover for rolling shutters. 18 gauge. 87 Providing and fixing ball bearing for rollong shutters. 88 Providing & laying of light cinder filling under floor of toilets & other sunken roofs. 89 Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. 90 Construction of drain along with apron. 91 Providing and supplying aluminium extruded tubular and other aluminium sections as per the architectural drawings and approved shop drawings , the aluminium quality as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in-Charge. ( The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account). for ACP & STRUCTURAL GLAZING WORK 92 Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of structural glazing (with open joints) for linear as well as curvilinear portions of the building for all heights and all levels, including: a) Structural analysis & design and preparation of shop drawings for the specified design loads conforming to IS 875 part III (the system must passed the proof test at 1.5 times design wind pressure without any failure), including functional design of the aluminum sections for fixing glazing panels of various thicknesses, aluminium cleats, sleeves and splice plates etc. gaskets, screws, toggles, nuts, bolts, clamps etc., structural and weather silicone sealants, flashings, fire stop (barrier)-cum-smoke seals, microwave cured EPDM gaskets for water tightness, pressure equalisation & drainage and protection against fire hazard including:b) Fabricating and supplying serrated M.S. hot dip galvanised / Aluminium alloy of 6005 T5 brackets of required sizes, sections and profiles etc. to accommodate 3 Dimentional movement for achieving perfect verticality and fixing structural glazing system rigidly to the RCC/ masonry/structural steel framework of building structure using stainless steel anchor fasteners/ bolts, nylon seperator to prevent bimetallic contacts with nuts and washers etc. of stainless steel grade 316, of the required capacity and in required numbers. c) Providing and filling, two part pump filled, structural silicone sealant and one part weather silicone sealant compatible with the structural silicone sealant of required bite size in a clean and controlled factory / work shop environment , including double sided spacer tape, setting blocks and backer rod, all of approved grade, brand and manufacture, as per the approved sealant design, within and all around the perimeter for holding glass. d) Providing and fixing in position flashings of solid aluminium sheet 1 mm thick and of sizes, shapes and profiles, as required as per the site conditions, to seal the gap between the building structure and all its interfaces with curtain glazing to make it watertight.Structural Performance Deflection and deformation by static air pressure test (1.5 times desing wind pressure without any failure) as per ASTME-330-10 testing method for a range upto 50 mm” 5. Seismic Movement Test (upto 30 mm) as per AAMA 501.4-09 testing method for Qualitative test” Tests to be conducted on site 6. Onsite Test for Water Leakage for a pressure range 50 kpa to 240 kpa (35psi) upto 2000ml” 93 Providing, assembling and supplying vision glass panels (IGUs) comprising of hermetically-sealed 6-12- 6 mm insulated glass (double glazed) vision panel units of size and shape as required and specified, comprising of an outer heat strengthened float glass 6mm thick, of approved colour and shade with reflective soft coating on surface # 2 of approved colour and shade, an inner Heat strengthned clear float glass 6mm thick, spacer tube 12mm wide, dessicants, including primary seal and secondary seal (structural silicone sealant) etc. all complete for the required performances, as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer-in-Charge. The IGUs shall be assembled in the factory/ workshop of the glass processor. (Payment for fixing of IGU Panels in the curtain glazing is included in cost of item No.26.2) For payment, only the actual area of glass on face # 1 of the glass panels (excluding the areas of the grooves and weather silicone sealant) provided and fixed in position, shall be measured in sqm (i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face # 2, + 12mm Airgap + 6mm Heat Strengthened clear Glass of approved make having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25-0.28) and U value of 3.0 to 3.3 W/m2 degree K etc. The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement. 94 Extra for openable side / top hung vision glass panels (IGUs) including providing and supplying at site all accessories and hardwares for the openable panels as specified and of the approved make such as heavy duty stainless steel friction hinges, min 4 -point cremone locking sets with stainless steel plates, handles, buffers etc. including necessary stainless steel screws/ fasteners, nuts, bolts, washers etc. all complete as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineerin- Charge. 95 Providing 10 mm thick plaster of Paris (gypsum anhydrous) ceiling up to a height of 5 m above floor level, over first class kail wood strips 25x6 mm with 10 mm gap in between and reinforced with rabbit wire mesh fixed to wooden frame (frame work to be paid separately): 96 Providing wood work in frames of false ceiling, partitions etc. sawn and fixed in position with necessary stainless steel screws etc. 97 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished seamless type tubes 98 Supplying and installation of Extruded Aluminium linear facade and curves not exceeding 3000mm radius with 150X50mm block and 100mm space along with top and bottom cover and capping for individual profiles, fixed on extruded aluminum rail 80mmX50mm powder coated with dulux Eelctro black ace (or any specified shade) spanning between supports of maximum distance of 1500mm with the help of Sainless steel Non slip barb, steel rivet- galvanised to class 3, aluminium clip coated with external grade Matt powder coating, including the cost of necessary fittings and fixtures etc. as per approved drawing and design from Architect in charge (make Citadel/ Woodform Architectural or equivalent) 99 Providing and fixing stone jali 40 mm thick throughout in cement mortar 1:3 (1 cement : 3 coarse sand), including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment, matching the stone shade, jali slab without any chamfers etc. Red sand stone 100 Design supply & installation of suspended Spider Glazing system designed to withstand the wind pressure as per IS 875 (Part-III). The Suspended System held with Spider Fittings of SS-316 Grade Steel of approved manufacturer with glass panel having 12 mm thick clear toughened glass held together with SS- 316 Grade Stainless steel Spider & bolt assembly with laminated glass fins 21 mm thick. The Glass fins and glass panel assembly shall be connected to Slab/ beams by means of SS- 316 Grade stainless steel brackets & Anchor bolts and at the bottom using SS channel of 50x25x2mm using fastener & anchor bolts, non staining weather sealants of approved make, Teflon/ nylon bushes and separators to prevent bi-metallic contacts, all complete to perform as per specification and approved drawings. The complete system to be designed to accommodate thermal expansion & seismic movements etc. The joints between glass panels (6 to 8 mm) and gaps at the perimeter & in U channel of the assembly to be filled with non staining weather sealant, so as to make the entire system fully water proof & dust proof. The rate shall include all design, Engineering and shop drawing including approval from structural designer, labour, T&P, scaffolding, other incidental charges including wastage, enabling temporary services all fitting fixers nut bolts, washer, Buffer plates, fastener, anchors, SS channel laminated glass etc. all complete. For the purpose of payment, actual elevation area of Glazing including thickness of joints and the portion of Glass panel inside the SS channel shall be measured. 101 Stone work (machine cut edges) for wall lining etc. (veneer work) upto 10 metre height, backing filled with a grout of average 12 mm thick cement mortar 1:3 (1 cement : 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade : (To be secured to the backing and the sides by means of cramps and pins which shall be paid for separately)Red sand stone - Exposed face machine cut and table rubbed with rough backing. 70 mm thick 102 Providing and fixing stainless steel cramps of required size and shape for anchoring stone wall lining to the backing or securing adjacent stones in stone wall lining in cement mortar 1:2 (1 cement : 2 coarse sand), including making the necessary chases in stone and holes in walls wherever required. 103 Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Wedge expansion type. Fastener with threaded dia 10 mm 104 Supplying, designing, fabricating, transporting, hoisting and fixing in position mural works in good quality of 70 mm Red sandstone and 6-10mm powder coated MS sheet in various elements for all levels. Stone shall be free from cracks, lines stains and even in shade for each element. The stone shall be fine grained and reddish or buff-colored (locally available). The work shall be carried out as per attached drawings with different process of i.e carving (manual/ by machine), ornamental work, traditional work, figure work (any type, any size), CNC cutting, moulding, etching, buffing and polishing. The carving and molding work shall be of very good quality. The work to be fixed in line, level and plumb in all respect with the use of brass clamps, pins, (to be paid separetely) dowels, cement slurry with matching pigment and Epoxy of Akemi Germany, Ardex Endura, MYK laticrete or approved make as required and as approved by the Architect in charge. 105 Centering and shuttering including strutting, propping etc. and removal of form for 106 Foundations, footings, bases of columns, etc. for mass concrete 107 Columns, Pillars, Piers, Abutments, Posts and Struts 108 SUB HEAD-I-SANITARY INSTALLATIONS 109 Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid 110 Providing & fixing toilet paper holderC.P. brass 111 Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge. 112 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm witha single 15 mm C.P. brass pillar tap 113 Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:- (a) White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer 114 Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. 115 Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms. 116 Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms. 117 Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. 118 Providing and fixing C.P.brass angle valve for basin mixer and geyser points of approved quality conforming to IS 8931 (including angle valve for WC flushing cistern, jet & kitchen sink) 15 mm nominal bore 119 Providing and fixing uplasticised PVC connection pipe with brass unions : 45 cm length 15 mm nominal bore 120 Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : 100 mm diameter 121 Providing and fixing CP Brass Single lever telephonic wall mixer of quality & make as approved by Engineer in charge. 15 mm nominal dia 122 Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. 15 mm nominal bore 123 Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not lessthan 190 gms. 124 Providing and fixing Stainless Steel AISI 304 (18/8) kitchen sink as per IS: 13983 with C.I. brackets and stainless steel plug 40 mm, including painting offittings and brackets,cuttingandmakinggoodthe walls wherever requiredKitchen sink with drain board 510x1040 mm bowl depth 200 mm 125 Providing & fixing PVC waste pipe for sink including PVC waste fittings Complete Flexible Pipe 32mm Dia 126 Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : 15mm nominal bore 127 Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.15mm nominal bore 128 Providing and fixing white vitreous china battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre & post flushing with water (250 ml & 500 ml consumption), having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of Engineer-in-charge. 129 Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as perdirection of Engineer-in-charge and finished smooth. Granite Stone of approved shade 130 Providing and fixing of Kent Elite Plus Water Purifier (RO+UV+UF+TDS Control) with flow rate (50L/hr)including all its accessories, complete in all respect including testing etc. 131 Providing and fixing of Water Cooler (Voltas Make) including all its accessories, complete in all respect including testing etc. 132 Providing and fixing of storage type (pressurised type) electrichot water heater copper sheet container, 25 mm thickinsulation, stove enamelled M.S. jacket thermostatically controlled immersion heater with pilot neon lamp, suitable length of electrical cable and 15 amp 3 pin plug top, complete in all respect including testing etc. Capacity 25 Liters 133 SUB HEAD-II-WATER SUPPLY 134 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. 135 Concealed work, including cutting chases and making good the walls etc. 136 For Internal Toilet 137 15 mm nominal outer dia Pipes 138 20 mm nominal outer dia Pipes 139 25 mm nominal outer dia Pipes 140 32 mm nominal outer dia Pipes 141 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. 142 Internal work - Exposed on wall 143 20 mm nominal bore 144 25 mm nominal bore 145 32 mm nominal bore 146 Providing and fixing GI pipes complete with GI fittings and clamps, i/c cutting and making good the walls etc. Internal work - Exposed on Wall 147 Terrace loop & Tank Filling Pipe 148 50 mm nominal bore 149 65 mm nominal bore (i/c two coat of synthetic enamel paint) 150 Supply, fixing, testing and commissioning of following Electrical Actuator Single Phase 220V AC Operated Wafer Type Butterfly Valve - IP65CB - 230VAC, as per specifications:- 151 Lehry Make Automatic OHT Level Control System Consist of Following Items 1) LEHRY Make On-Off Type Electrical Actuator Single Phase 220V AC Operated Wafer Type Butterfly Valve with CI Body & SS Disc 2) Level Float Switch- 5M 3) Control Box (a) IP 65 Finishing(250 x 160 x 115)mm (b) LED Lamps: Tank FULL, Tank EMPTY, Power (c) Power supply toggle switch (d) Accepts 230V Single Phase power supply and provides 24VAC to float switch and 230VAC to valve coil. (e) Accepts NO/NC feedback from float switch. 50mm 152 Painting G.I. pipes and fittings with synthetic enamel white paint with two coats over a ready mixed priming coat, both of approved quality for new work : 50mm diameter pipe 153 Providing, Fixing, Testing & Commissioning of XLPE Insulation of 9mm thickness on hot water supply pipes. Astral orequivalent approved complete in all respect as directed by Engineer-in-charge. 154 15mm dia (9 mm thickness) 155 20mm dia (9 mm thickness) 156 Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete : 50 to 80 mm nominal bore 157 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 158 For vertical pipe connection with terrace ringmain 159 20 mm nominal bore 160 25mm nominal bore 161 32mm nominal bore 162 50mm nominal bore 163 65mm nominal bore 164 Providing and fixing MS pipe puddle flanges of required size with 600mm long with 6mm thick MS plate of size 300mm x 300mmof suitable size properly fixed in RCC walls of water tanks, including necessary welding complete in all respect as per details shown on darwings and directions of Engineeer-in-charge for water tanks. 165 25mm dia. 166 50mm dia. 167 65mm dia. 168 150mm dia. 169 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS :13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 110 mm dia (for rain water) 170 Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A,including jointingwithsealringconformingtoIS: 5382, leaving 10 mm gap for thermal expansion. 171 Single Push Fit Coupler 172 110 mm dia 173 Single tee with door 174 110x110x110 mm 175 Plain bend 87.5 deg 176 110 mm dia 177 Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 110 mm dia 178 Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. 179 SUB HEAD : IV - INTERNAL DRAINAGE 180 Providing, fixing, jointing and testing,uPVCSWR pipes, - type B conforming to IS : 13592to wall, ceiling and floor, approved quality, complete, for soil, waste & rain water drain including pushfit jointing with seal ring. (i) Single socketed pipes. 181 Internal Toilet (Soil & Waste Pipe) 182 75 mm 183 110 mm 184 Exposed on Wall (Soil & Waste Pipe) 185 110 mm 186 Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC pipes including jointing with seal ring leaving 10 mm gap for thermal expansion. 187 Bend without door (87.5°) 188 110mm bend 189 Bend without door (45°) 190 100mm 191 75mm 192 Y Fitting without door 193 100mm 194 75mm 195 Reduced Y Fitting without door 196 100mm x 75mm 197 Single Tee without door 198 110mm 199 75 mm 200 Single Tee with door 201 110mm 202 Reduced Tee with door 203 110mm x 75mm 204 Coupler 205 110mm 206 Clean Out Plug (COP) 207 110mm 208 75 mm 209 Vent Cowl 210 110mm 211 Providing, fixing, jointing and testing, unplasticized PVC pipes - 10 kg/cm2 confirming to IS : 4985 to wall, ceiling and floor, approved quality, complete, for waste water drain including jointing with rubbering/solvent/solution and airtight joints, etc. 212 For Wash basin & Urinal 213 50mm dia. Pipe 214 32mm dia. Pipe 215 Elbow (90°) 216 50mm 217 32mm 218 Elbow (45°) 219 50mm 220 32mm 221 T fitting 222 50mm 223 32mm 224 Providing, fixing, jointing and testing ,ofPVC Multi Floor Trap without jali ofminimum 50 mm water seal, making necessarycuttingin slabor floors and making goodincluding supports with cement concrete 1:3:6complete as approved by Engineer-in-Charge.110mm x 75mm x 50mm/40mm (Toilet) 225 Providing, fixing, jointing and testing , ofPVC NahaniTrap without jali ofminimum 50 mm water seal, making necessarycuttingin slabor floors and making goodincluding supports with cement concrete 1:3:6complete as approved by Engineer-in-Charge. 226 110mm x 75mm (Toilet) 227 110mm x 75mm (Kitchen) 228 Providing and fixing PTMT grating of approved quality and colour.Rectangular type with openable circular lid 150 mm nominal size square 100 mm diameter of the inner hinged round grating (including balcony) 229 Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design : 150 x 100mm size P-type With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 230 Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete: 100 mm diameter 231 Excavating trenches of required width for pipes cables etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m ncluding getting out the excavated soil , and then returning the soil as required , in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed , within a lead of 50 m. All kind of soil Pipes, cables etc. exceeding 80 mm dia . But not exceeding 300mm dia. 232 Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W.pipes including bed concrete as per standard design: 100mm dia SWpipe 233 COST OF SEWERAGE WORKS 234 Excavating trenches in all kinds ofsoil of required width for pipes. including excavation for sockets and dressing of sides, ramming of bottoms, including getting out the excavated soil & then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc & disposing of surplus excavated soil as directed within a lead of 50m. up to 1.50 m depthPipes 80 mm to 300 mmdiameter 235 Opentimbering in trenches including shuttering and shoring complete. (Measurement to be taken of the face area timbered) Depth not exceeding 1.5 meter 236 Providing and laying NonpressureNP 2 class (light duty) RCC pipe with collars jointed withstiffmixtureofcement mortar in the proportion of 1:2 (1cement : 2 finesand ) includingtestingof joints etc. complete. 150 mm.dia. RCCPipes 237 Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand : 10 graded stone aggregate 40mm nominal size) upto the haunches of pipes including bed concrete as per standard design 150 mm. dia. 238 Constructing brick masonry manhole in cement mortar 1:4 (1 cement :4 coarse sand) RCC top slab with 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1 cement :4 coarse sand :8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with floating coat fo neat cement and making channels in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm nminal size) finished with a floating coat of neat cement complete as per standard design. Inside size 90x80cms and 45cms deep including CI cover with frame (light duty) 455x610mm internal diamensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15kg). With common burnt clay FPS (non modular) bricks of class designation 75 (i) For Sewer Line 239 Extra for depth for manholes: 240 Size 90x80cm with With common burnt clay FPS (non modular) bricks of class designation 7.5 241 Inside size 90x120cms and 90cms deep including CI cover with frame (medium duty) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg (weight of cover 58 kg and weight of frame 58kg).With common burnt clay FPS (non modular) bricks of class designation 75 (i) For Sewer Line 242 Extra for depth for manholes: Size 90x120cm with With common burnt clay FPS (non modular) bricks of class designation 7.5 243 Providing orange colour safety footrests of minimum 6 mm thick plastic encapsulated as per IS:10910 on 12 mm dia steel bar conforming to IS:1786 having minimum cross section as 23 mm x 25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm thread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufactures permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design. 244 Supply, installing, testing and commissioning of non clog submersible type drainage / dewatering pumpset 245 COST OF EXTERNAL WATER SUPPLY WORKS 246 Providing & fixing G.I. pipes complete with G.I. fittings includingtenching and refilling etc. (external work) 247 65mm nominal bore. 248 50mm nominal bore. 249 32mm nominal bore. 250 Providing and fixing gate valve (with cap complete with bolts, nuts, rubber insertion etc. 251 65mm nominal bore. 252 50mm nominal bore. 253 32mm nominal bore. 254 Constructing masonry Chamber 90X90X100 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand ) for sluice valve, with C.I. surface box 100mm, top diameter, 160 mm bottom diameter and 180mm deep (inside) with chained lid and RCC top slab 1:2:4 mix ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 (1 cement :5 fine sand : 10 graded stone aggregate 40mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand ) 12 mm thick finished with a floating coat of neat cement complete as per standard design : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 255 Constructing masonry Chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size ) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick,finished with a floating coat of neat cement complete as per standard design : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 256 RAIN WATER HARVESTING 257 RECHARGE PITS 258 Earth work in exacavation in trenches for foundations and for pipes cables etc. in ordinary soil(loam clay or sand) including lift upto 1.5 m and dressing of sides and ramming of bottom sand disposal of surplus excavated earth as directed by the Engineer i/c with in a lead of 50m. 259 In all kind of soil upto 1.5m depth 260 In all kind of soil upto 1.5m to 3.0m. depth 261 In all kind of soil upto 3.0m to 4.5m. depth 262 In all kind of soil upto 4.5 m to 6.0m. depth 263 Providing and laying in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded Stone aggregate 20 mm nominal size) and curing complete,including cost of form- work,in foundation and floors. 264 Class M-150 brick work in 1:4 cement coarse sand mortar infoundation & plinth including supply of all materials, labour, tools and plants etc. required for proper completion of the work. 265 Reinforcement cement concrete work in RCC culvert slab with 1:1.5:3 (1 cement : 1.5 coarse sand and 3 gradded stone aggregate of 20 mm nominal size) excluding centering and shuttering and reinforcement. 266 Providing & Fixing Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level. 267 12mm cement plaster on rough side of single or half brick wall mix1:3 (1 cement : 3 Coarse sand) 268 Providing M.S. foot rests including fixing in manoholes with 20x20x10 cm cement concrete blocks 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) as per standard design: With 20x20mm square bar 269 Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality. M.D. -10- Circular shape 500mm internal diameter 270 Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, beyond 90 metre & upto 150 metre depth below ground level. Drilling of 300mm dia bore hole manually. 271 Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 150 mm nominal size dia 272 Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads& lifts, all complete as per direction of Engineer-in-charge. 273 Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, inrequired thickness, for all leads & lifts, all complete as per directionof Engineer-in-charge. 274 Supplying, filling, spreading & leveling coarse sand of size range 1.5mm to 2 mm in recharge pit, in required thickness over gravel layer,for all leads & lifts, all complete as per direction of Engineer -incharge. 275 Gravel packing in tubewell construction in accordance with IS: 4097,including providing gravel fine/ medium/ coarse, in required grading& sizes as per actual requirement, all complete as per direction ofEngineer-in-charge. 276 DESILTING CHAMBER 277 Earth work in exacavation in trenches for foundations and for pipes cables etc. in ordinary soil(loam clay or sand) including lift upto 1.5 m and dressing of sides and ramming of bottom sand disposal of surplus excavated earth as directed by the Engineer i/c with in a lead of 50m. 278 In all kind of soil upto 1.5m depth 279 In all kind of soil upto 1.5m to 3.0m. depth 280 Providing and laying in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded Stone aggregate 20 mm nominal size) and curing complete,including cost of form- work,in foundation and floors. 281 Class M-150 brick work in 1:4 cement coarse sand mortar infoundation & plinth including supply of all materials, labour, tools and plants etc. required for proper completion of the work. 282 Reinforcement cement concrete work in RCC culvert slab with 1:1.5:3 (1 cement : 1.5 coarse sand and 3 gradded stone aggregate of 20 mm nominal size) excluding centering and shuttering and reinforcement. 283 Providing & Fixing Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level. 284 15mm cement plaster on rough side of single or half brick wall mix 1:3 (1 cement : 3 Coarse sand) 285 Providing M.S. foot rests including fixing in manoholes with 20x20x10 cm cement concrete blocks 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) as per standard design: With 20x20mm square bar 286 Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality. M.D. -10- Circular shape 500mm internal diameter 287 DRAINAGE NETWORK 288 Excavating trenches in all kinds ofsoil of required width for pipes. including excavation for sockets and dressing of sides, ramming of bottoms, including getting out the excavated soil & then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc & disposing of surplus excavated soil as directed within a lead of 50m. up to 1.50 m depth Pipes 80 mm to 300 mmdiameter 289 Providing and laying NonpressureNP 2 class (light duty) RCC pipe with collars jointed withstiffmixtureofcement mortar in the proportion of 1:2 (1cement : 2 finesand ) includingtestingof joints etc. complete. 150 mm.dia. RCCPipes 290 Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand : 10 graded stone aggregate 40mm nominal size) upto the haunches of pipes including bed concrete as per standard design 150 mm. dia. 291 Constructing brick masonry INSPECTION chamber 60x60x75 cm with bricks of class designation 50 in cement mortar 1:4 (1 cement : 4 coarse sand) including CI cover with frame LIGHT WEIGHT complete as perdesign. With FPS bricks 292 Constructing brick masonary open surface drain with bricks of class designation 75 in cement mortar 1:4 (1 cement : 4 fine sand) including earth excavation, 10cm thick bed concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size) and 25mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 12.5mm nominal size) for filling haunches including 12mm cement plaster 1:4 (1 cement : 4 coarse sand ) with a floating coat of neat cement inside the drain, its top and exposed side including disposal of surplus earth complete as per standard design: 293 Drain 300 wide average.Depth 45 cm with R.C.C. slab 294 Drain 450 wide average.Depth 45 cm with R.C.C. slab 295 SEPTIC TANK & SOAK PIT 296 Size :- Length = 7.50 M. Width = 2.65M Total Depth =3.00M 297 Earth work in excavation over areas including disposal of excavated earth, lead upto 50m, disposed earth to be levelled and neatly dressed. 298 In all kind of soil upto 1.5m depth 299 In all kind of soil upto 1.5m to 3.0m. depth 300 In all kind of soil upto 3.0m to 4.5m. depth 301 Providing and laying of cement concrete in base excluding the cost of centring and shuttering by 1:2:4 (1 cement : 2 coarse sand : 4 gradded stone aggregae 40mm nominal size) 302 Brick work with brick of class designation 150 in foundation and plinth in cement mortar (1 cement : 4 coarse sand) 303 Reinforcement cement concrete work in RCC culvert slab with 1:1.5:3 (1 cement : 1.5 coarse sand and 3 gradded stone aggregate of 20 mm nominal size) excluding centering and shuttering and reinforcement. 304 P/F Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level. 305 12mm cement plaster on rough side of mix 1:3 (1 cement : 3 coarse sand) 306 Providing M.S. foot rest including fixing with 20x20x10 cm. cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 gradded aggregate of nominal size 20mm ) as per standard design with 20x20mm sq bars. 307 Providing and fixing C.I. tee at the inlet and outlet of septic tank. 308 Providing & fixing 75mm dia vent pipes. 309 Providing & fixing of 75mm dia cast iron terminal guard. 310 Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality. 311 M.D. -10- Circular shape 500mm internal diameter 312 M.D. -2.5- Circular shape 450mm internal diameter 313 Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks of class designation 75 and S.W. drain pipe 100 mm diameter, 1.8m long complete as per standard design. With F.P.S. bricks 314 CONSTRUCTIONOFTUBEWELL(suitable for 1000 lpm yield) 315 Transportation Charges of drilling equipment including assembly and other material as required. 316 Drilling of 675 mm. dia by rotary machine 317 Supply & laying of 350 mm. dia housing pipe (8 mm. thick) 318 Supply & laying of 200 mm. dia blind pipe (8 mm. thick) 319 Supply & laying of 200 mm. dia slotted pipe (8 mm. thick) 320 Supply & fixing of 350 mm. dia Socket 321 Supply & fixing of 200 mm. dia Socket 322 Supply & fixing of 200 mm. dia Bail plug 323 Supply & fixing of 350 mm. dia well cap 324 Supply & fixing of 350x200 mm. dia reducer. 325 Supply & fixing of 350 mm. dia housing clamp 326 Supply & Filling of pee gravel 2 mm. 4 mm. in side of bore after lower and development as required as per direction of E/I. 327 Development by air compressor including Transportation. 328 Development by O.P. Unit including Transportation. 329 Supply of submersible pump suitable for tube well capable of pumping clear and cold water free from chemical and directly coupled with electric moter operating of 415 volt suitable for 3 phase 50 cycle A.C. Supply of following duty condition. A - Discharge of water in LPM 860 Approx size of discharge outlet in 80 mm. B - Total Head of pump set 45 m. 330 Supply and fixing of finolex or equivalent ISI marked submersible copper cable of size 2x3x2.5 sq. mm. 331 Supply of control panel cubical type wall mounted vermin proof with internal wiring duly enameled painted and mechanically finished having L&T of qul. Male switch fuse unit with HRC fuses, Ameter, Boltmeter, Selector switch, phase indicating lamp with bulbs, instrument fuses, power capcitor single phase preventor etc. complete set with supply of Jyoti or eq. Air break Star- Delta motro starter suitable for above submersible pump set. 332 Supply of 80mm dia M.S. column pipe of class C both and socketed with heavy sockets in 3/6 meter length and one end flanged complete with interlocking arrangements. 333 Supply of 80mm dia M.S. column pipe clamps with nut, bolts, packing etc. 334 Supply of 80mm dia C.I. double flanged ISI mark reflex valve of updadhya or equ. Make. 335 Supply of 80mm dia C.I. double flanged ISI mark sluice valve with hand wheel of upadhya or equ. Make. 336 Supply of C.I. double flanged bend of 80mm dia i/c cost of material and labour. 337 Supply of 80mm dia C.I. tee heavy quality i/c cost of material. 338 Supply of Guru/Fibing or equivalent make pressure gauge. 339 Erection & commissioning of pumping plants complete along with electric wiring. 340 Supply of steel wire rope of 1/2 size 341 S/B of 600mm x 600 mm x 6.0 mm G.I. plate vertically for earthing with its top at least 3 metres below ground level complete with 20mm dia G.I. pipe and funnel for watering and one earthing lead on one no. 8 to 10 SWG GI wite in 15mm dia G.I. pipe up to switch board (from appron to switch board the cost of G.I. , pipe and G.I. wire will be extra) 30 cm square C.I. frame with hinged cover masonry housing alternate layers of charcoal. coke and salt at least 150mm thick alround etc. as per directions of E/I complete in all respects as per drawing. 342 S/F of one number 8 to 6 SWG G.I. wire in 15mm dia G.I. Pipe for earthing, laid in ground or in wall duly concealed includingn the cost of cement, sand labour. T&P other material required for proper completion of the work as directed at site. 343 S/F of aluminium conductor PVC insulated armoured, served, sheathed cable 1100 volts grade at a depth of 750mmbelow ground level over a cushion of 75mm thick sand alround and protected with burnt bricks on sides and on top.On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by E/I complete in all respects The armoring of the cable shall be properly connected with the earth conductor by clamps etc. 16 sqmm x 4 core 344 FIRE FIGHTING SYSTEM 345 Excavating trenches of required width for pipes cables etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m ncluding getting out the excavated soil , and then returning the soil as required , in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed , within a lead of 50 m. Pipes, cables etc. exceeding 80 mm dia . But not exceeding 300mm dia. 346 Providing, laying, testing & commissioning of C class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 100 mm nominal bore (pipe in pump room & external) 347 Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904as required : 2 way - 100 mm dia M.S. Pipe (Siamese& draw out connection) 348 SUB HEAD-II: INTERNAL FIRE FIGHTING WORKS(HYDRANT SYSTEM) 349 Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump)(a) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical confirming to IS : 1520b) Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horiziontal foot mounted type with Class-F insulation, conforming to IS-325.(c) M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required.(d) Suitable cement concrete foundation duly plastered and with anti vibration pads.450 lpm at 35 m Head 350 Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required. (for terrace booster pump) 351 Providing and fixing in position the industrial type pressuregauges with gun metal / brass valves complete as required (for terrace booster pump) 352 Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : 100 mm dia. 353 Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required : 100 mm dia. 354 Providing, laying, testing & commissioning of C class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 355 80 mm nominal bore 356 100 mm nominal bore 357 Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required :Single headed Gunmetal 358 Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required.20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 20 mm nominal internal dia gun metal globe valve & nozzle. Drum and brackets for fixing the equipmets on wall. Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket.40 m 359 Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required :Gun metal 360 Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required :Gun metal 361 Providingandfixing standard fire mans axe with heavy duty insulated rubber handle. 362 Providing of FHC Door made of 16 gauge MS Sheet with frame of size 105x70mm complete door and frame assembly including all hardwares (Concealed Flush handle,Allen Key Lock, MS Hinges, 5mm Thick Float glass) & accesories . The door to be painted with fire resistance paint. The scope shall also include the painting of the frame with the same paint as the shutter or complete as per direction of Engineer-in-charge.(Approx. size of door:900mm Wide & 1500mm Height) 363 Supplying and fixing orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required. 364 Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and paintingwith synthetic enamel paint of approved shade as required. 365 SUB HEAD-III: FIRE EXTINGUSHER 366 Supply and fixing of C02 type fire extinguisher 4.5 kg. capacity (ISI Marked IS : 2878 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. 367 Supply and fixing of fire extinguisher, ABC Type 6.00 kg. capacity (ISI Marked IS : 15683 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. 368 Providing and fixing Fire related signages printed on photoluminescent U1000 aluminium sheet of 1.0 mm (+-10%) containing Lumigen II as base chemical, covered under UV stablized coating and of appropriate sizeincluding fixing on wall, door, ceiling etc. with proper clamps, hangers, cleats, anchor fasteners etc. complete in all respects as directed by Engineer-in-charge. 369 SUB HEAD-IV: ELECTRICAL WORKS (For Terrace Pump) 370 Supply and laying of aluminium conducter, PVC insulated armoured, served, sheeted cable 1000 bolts grade at a depth of 750mm below ground level over a cushion of 75mm thick sand alround and protected with burnt bricks on sides and top on surface, the cable run shall be fixed on M.S. clamps etc. of suitable size. 3CX6Sqmm AL XLPE Cable 371 Supply & fixing of brass nickle plated compression gland for PVC insulated & armoured served sheathed, underground cable including rubber ring etc. complete in all respects. The armouring of the cable shall be properly connected with the earth as per dire 3CX6Sqmm AL XLPE Cable 372 Fabricating & Supply, installing, testing and commissioning ofsheet steel clad floor mounting control panel having suitable size for control of 1 nos. booster pumps 5.5 KW/7.5HP each having suitable incoming MCCB, incoming voltmeter with selector switch and fuses. DOL Starter with hand reset overload cum single phase preventor type relay, Ammeters to read current in any one phase, alarm with reset push button which will automatically reset for the next cycle.(As per the Technical Specifications)(At Terrace floor) 373 Supplying and installing following size of perforated pre-painted M.S.cabletrayswithperforationnotmorethan17.5%,in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.150 mm width x 50mm depth x 1.6 mm thickness. 374 SCHEDULE OF QUANTITIES FOR ELECTRICAL WORKS 375 SUBHEAD I- WIRINGPOINTS 376 Wiring point for light with 1.5 sq. mm.FRLSH PVC insulated multistrand single core copper conductor cable in PVC conduit pipe partly concealed in the wall and partly laid in slab alongwith the reinforcement before concreting, complete with 14 SWG copper earth continuity wire,GP Box, piano type switch & ceiling rose/angle/batten holder on 3mm thick phenolic paminated backalite sheet etc complete in all respect as directed including matching colour wash 377 Wiring point for fan / fresh air fan (light duty exhaust fan) with 1.5 sq.mm.FRLSH PVC insulated multistrand single core copper conductor cable in PVC conduit partly concealed in wall and partly laid in slab alongwith the reinforcement before concreting, complete with 14 SWG copper earth continuity wire,GP Box , piano type switch & ceiling rose on 3 mm. thick backelite sheet etc., complete in all respect including matching colour wash. 378 Wiring point for 5Amp plug with 1.5 sq. mm.FRLSH PVC insulated multistrand single core copper conductor cable in heavy guage rigid steel conduit partly concealed in wall and partly laid in slab alongwith the reinforcement before concreting, complete with14 SWG copper earth continuity wire and piano type switch and socket etc., complete in all respect including matching colour wash. 379 Addition when modular type switches etc are used in place of piono type switches etc. in various wiring points. 380 Addition for light / fan points with modular type switchin place of piono type switch. 381 Addition for plugpointswith modular type switchin place of piono type switch. 382 Addition for Exhaust fanpointswith modular type switchin place of piono type switch. 383 Supply and fixing of power plug with 15A/250 V flush type switch and 5 Pin 15 A/250V flush type universal socket in suitable M.S. box of 175mmx100x50mm size with phenolic laminated bakellite sheet cover 3mm thick fixed with brass machine screws and cup washer. 384 Supply and fixing of power plug with 20A/250 V flush type switch and 5 Pin 20 A/250V flush type universal socket in suitable M.S. box including supply of all material, labor T&P etc. required for proper completion of work. 385 Supply & wiring of submains with 2 nos. 2.5 sq.mm & with 1 no. earth wire of 1.5 sq.mm FR PVC insulated 1100 V grade single core multistrand copper conductor cable in 20 mm dia heavy duty (2mm thick) PVC conduit complete, including supply of all material, labourand T&P etc. required for proper completion of the work as directed by Engineer I/C. 386 Supply and wiring of submain 2 number 4 sqmm . FRLSH PVC insulated 1100 V grade multistranded single core copper conductor cable in heavy duty( 2 mm thick ) 20mm dia PVC conduit partly concealed in wall and partly laid in slab along with one number 2.5 sqmm FRLSH PVC insulated multistranded copper conductor cable as earth contunity wire etc. complete in all respects. 387 Supply and wiring of submain 2 number 6 sqmm . FRLSH PVC insulated 1100 V grade multistranded single core copper conductor cable in heavy duty( 2 mm thick ) 20mm dia PVC conduit partly concealed in wall and partly laid in slab along with one number 4 sqmm FRLSH PVC insulated multistranded copper conductor cable as earth contunity wire etc. complete in all respects. 388 Supply and wiring of submain 2 number 10 sqmm . FRLSH PVC insulated 1100 V grade multistranded single core copper conductor cable in heavy duty( 2 mm thick ) 25mm dia PVC conduit partly concealed in wall and partly laid in slab along with one number 6 sqmm FRLSH PVC insulated multistranded copper conductor cable as earth contunity wire etc. complete in all respects. 389 Supply and wiring of submain 4 number 10 sqmm . FRLSH PVC insulated 1100 V grade multistranded single core copper conductor cable in heavy duty( 2 mm thick ) 32mm dia PVC conduit partly concealed in wall and partly laid in slab along with two number 10 sqmm FRLSH PVC insulated multistranded copper conductor cable as earth contunity wire etc. complete in all respects. 390 Supply and wiring of 4 number 16 sq. mm. PVC insulated 1100 V grade single core Copper conductor cable in 40 mm dia PVC conduit concealed in wall, with two number 10 sqmm single core Copper conductor cable as earth continuity wire drawn in coudit including matching colour wash etc., cable as earth contunity wire etc. complete in all respects. 391 Supplyfixingand concealing of20mm dia.2mm thick PVC conduit pipe with ISI mark embossed and with PVC acessories confirming to IS No. 3419 for drawing wires duly sealed at joints with original resin/ adhesive to make the complete piping rigid,plastering with cement sand mortar finished to level with matching colour including cost of material labour and T & P etc required for proper completion of work( forTelephone) 392 SUBHEAD II-INSTALLATION OF LIGHT FIXTURES AND FANS 393 Erection and testing of ceiling fan and regulator for room height upto 3.5mts. including supply of 3mm thick G.I. Pipe 19mm dia duly painted, complete in all respects. 394 Erection and testing exhaust fan on the exhisting hole with suitable size of rag bolts nuts and washers etc. complete in all respects. 395 Supply and fixing hexagonal/Round G.P. fan box of approved make made up of 1.0mm thick ISI Marked G.P. sheet spot weeldeed Four to Eight holes of 25.4 mm for pipe entry of the box. Holes should be semi-shuttered type with 0.5mm G.P. Sheet made upper & lower cover duly screewed fitted with 300mm round zink coted M.S Bar X 12mm & brand name should be embossed.Fixing with wiring conduit laid in the R.C.C roof before concreting alongwith supply of all material, labour, T&P etc. required for proper completion of the work. 396 Supply of Ceiling Fan with fan motor of A.C Permanent insulation, capacitor rating conforming BEE 5 star rating and IS:374/79 and also comply with IS: 1709/1984 with latest amendment. The rated voltage 220/240 volts, 50Hz, 1-ph AC the fan assemble should consists of down road blades, shackle canopies etc and with double ball bearing system.BEE 5 Star rated-1200mm sweep 397 Supplyfixingofelectronic fan regulator(Modular) 120-280 V. ISImarked, on the existing switch board including making connetion, required material, labour T/P etc for proper completion of work to the satisfaction of Engineer in charge of work. 398 Supply and fixing of recess/surface mounting round 24 to 32 Watt LED Down Lighter having Powder coated die cast aluminium housing with extended heat sink, diffuser/ Reflector and driver set complete in all respect.CAT- AAA 399 Supply and fixing of 1X1 recess/surface mounting 18 Watt to 20 Watt LED Down Lighter having Powder coated die cast aluminium housing with extended heat sink, diffuser/ Reflector and driver set completed in all respects.CAT- AAA 400 Supply & fixing of LED Tube Light with Metal heavy dutyBox type batten Light fitting 2 x 22 watt suitable for up to 2 x 22 watt LED Polycarbonate tube light complete including tube etc suitable for both surface & surface complete in all respects.(CAT: AAA) 401 Supply & fixing of LED Tube Light with Metal heavy dutyBox type batten Light fitting 1 x 22 watt suitable for up to 1 x 22 watt LED Polycarbonate tube light complete including tube etc suitable for both surface & surface complete in all respects.(CAT: AAA) 402 Supply & fixing of recess/Surface mounting round 6 to 8 watt, LED Down Lighter having Powder coated die cast aluminium housing with heat sink, diffuser/ Reflector and driver set, suitable for 24Hr continuous Operation,complete in all respect.(CAT: AAA) 403 Supply and fixing of water tight oblong 10 watt LED bulhead luminaire with driverr set confirming to IP 65 and above Protection complete in all respect.(CAT: AAA) 404 Supply and fixing ofbatten/angle holder complete all respect. 405 Supply and fixing of 3 Watt LED Path / Walkover luminaire having powder cotated die cast aluminium body with drive set . Confirming to IP 65 Protection complete in all respect.CAT-AAA 406 Supply and fixing of factory wired integral LED flood light luminaires with die cast aluminium housing built with dirver set suitable for 40 to 50 Watt. Confirming to IP 65 protection complete in all respect.CAT-AAA 407 NON SCH. 408 Supply and fixing of 17 watt LED Mirror Light and complete in all respect. 409 Supply and fixing of 12 watt LED bulb complete in all respect. 410 Supply and fixing of 40 watt Tungsten Filament Antique Glass Light Incandescent Bulbs Vintage Base E27 Bulb Yellow Light. complete in all respect. 411 Supply and fixing of Dome Shape Pendent Light,complete in all respect, Make : Havells, Wipro, Philips ,Jaguar,Bajaj or Eq. 412 SUBHEAD III-DISTIBUTION BOARD 413 Supply and fixing of surface/flush mounting distribution boards with additional metal door without MCB complete in all respects.(CAT A) 414 8 Way SPN 415 12 Way SPN 416 6 Way TPN 417 8 Way TPN 418 4 Way VTPN 419 Supply and fixing of 6Amp to 32 Amp (10 KA)SP MCB in existing MCB, DB complete with connections as required. (CAT: A) 420 Supply fixing and making connection of following MCBS complete in all respects as per direction and satisfaction of engineer-in-charge.(CAT: A) 421 6 Amp. to 32 Amp. DP MCB (10 KA) C Curve(CAT: A) 422 40 Amp. TP MCB(CAT: A) 423 40 Amp. FP MCB(CAT: A) 424 63 Amp. FP MCB(CAT: A) 425 S&F and making connection of 25A 2 pole 30mA ELCB/RCCB of Din Rail Mounting complete in all respect as per direction and satisfaction to the Engineer in charge. 426 S&F and making connection of 40A 2 pole 30mA ELCB/RCCB of Din Rail Mounting complete in all respect as per direction and satisfaction to the Engineer in charge. 427 Supply and fixing Single Pole MCBS Blanking Plate complete in all respects. (CAT: A) 428 Non-Sch. 429 Supply fixing and making connection of following MCCBS complete in all respects as per direction and satisfaction of engineer-in-charge. 63 Amp. FP MCCB (25 KA) Thermal Magnetic release 430 SUBHEAD IV-CABLES 431 Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc 432 300 sq. mm 3.5 core 433 185 sqmm3.5 core 434 35 sqmm3.5 core 435 25 sqmm3.5 core 436 6 sqmm3 core 437 Supply and fixing of brass nickle plated compression gland for PVC insulated & armoured served sheathed, underground cable including rubber ring etc. complete in all respect. The armouring of the cable shall be properly connected with the earth as per direction of EngineerIncharge 438 300 sqmm3.5 core 439 185 sqmm3.5 core 440 35 sqmm3.5 core 441 25 sqmm3.5 core 442 6 sqmm3 core 443 Supplying and fixing of Palm / pin type copper tin plated cables sockets (lugs) to the cable leads, insuslating with tape and making of connections etc. complete in all respects as per direction of Engineer-Incharge. 444 300 sqmm 445 185 sqmm 446 150 sqmm 447 95 sqmm 448 35 sqmm 449 25 sqmm 450 16 sqmm 451 6 sqmm 452 SUBHEAD V-EARTHING 453 Supply and burying of 600mm x 600 mmx6mm G.I. plate, vertically for earthing with its top atleast 3 mts. below ground level complete with 20mm G.I.pipe and funnel for watering and two earthing leads of No.8to10SWG G.I.wire in 15mm dia G.I. pipe upto switch board (from apron to switch board the cost of G.I. pipe and G.I. wire will be extra) 30cm. square C.I. frame with hinged cover, masonary housing, alternate layers/of charcoal/ coke and salt at least 150mm thick alround etc. complete in all respects. 454 Supply and burying of 600mm X 600mm X 3 mm copper Plate vertically for earthing with its top at least 3 metres below ground level complete with 20mm dia G.I pipe and funnel for watering and one earthing lead ofone no. 8SWG copper wire in 15 mm dia G.I pipe up to switch board ( from appron to switch board the cost of G.I pipe and copper wire will be extra) 30 cm square C.I frame with hinged cover masonry housingalternate layers of charcoal / coke and salt atleast 150mm thick alround etc. as per directions of Engineer in charge complete in all respects. 455 Supply and laying of 32mm x 6mm G.I. strip from earth electrode directly in the ground as required complete in all respects. 456 Supply and Laying of 32mm X 6 mm Copper strip from earth electrode directly in the ground as required complete in all respects.. 457 Supplying & Laying of 25mmx3mm G.I. Strip for earthing purpose as required complete in all respects. 458 Supply & fixing of two number 8 SWG G.I. wire in 15mm dia GI pipe for earthing purpose as required complete in all respects. 459 L.T. PANEL 460 Supply, installation, testing and commissioning of electrical panel, modular type, front accessible only, free floor standing confirming to Minimum IP:43 degree of protection.The panel sheet structure shall undergo seven tank pre-treatment process before painting.The sheet steel shall be all of 2.0mm thick CRCA sheet.All the openable compartments of the panel shall be completely shrouded and provided with padlocking arrangement on all compartments including bus bar and cable alley chambers.The panel height shall not exceed 2200mm and the maximum operating height for any switchgear shall not be more than 1700mm.The panel shall be provided with minimum 75mm base channel frame fabricated from ISMC sections.All bus bar links in the panel shall be solid bus bars with coloured PVC shrinkable sleeves, no wires will be acceptable.Continuous earth bus shall run alround the panel with earthing studs provided at minimum 2 places.The control wiring shall be carried out with minimum 1.5/2.5 sqmm copper wires and adequate number of NO/NC, potential free contacts incorporated for remote operation of the starters.Proper sized cable termination gland plates shall be provided oncable alleys and knockouts for same shall be provided during fabrication stage itself.The panel shall be provided with a thermostatically controlled heating arrangement (200 W) to take care of high humidity conditions.A 5A socket service outlet (single phase) shall be provided in one of the compartments as ervice outlet in the panel.Panel shall be so designed at to have minimum 20% spare feeders/space.Panel shall undergo epoxy powder coated paint, colour as per IS:5 requirement.All cable terminations shall be from top.The complete panel shall be fuse less type, for control circuits 2A/6A MCBs to be used.All bus bars shall be of aluminium, electrolytic grade only.Maximum design density shall not exceed 1 Amps/Sqmm.All bus bars shall be insulated with coloured heat shrinkable PVC sleeved.All bus bar supports shall be non hygroscopic DMC/SMC supports. The panel shall be manufactured in conformance to requirements of local electrical inspector and it shall be contractors responsibility to get initial approval of drawings and also final approval of complete electrical works related to this section. 461 The minimum clearances between bus bars shall be as follows :Phase to phase - minimum 20mmPhase to neutral-minimum 15mmBUILDING MAIN LT PANELIncoming :1 No 250 Amp. 4P MCCB of 25KA (Ics=Icu)Breaking Capacity1 No 200 Amp. 4P MCCB of 25KA (Ics=Icu)Breaking Capacity1 No 125 Amp. 4P MCCB of 25KA (Ics=Icu)Breaking Capacity1 No 63 Amp. 4P MCCB of 25KA (Ics=Icu)Breaking Capacity1 No 200 Amp. 4P ATSMetering :1 Set of CTs one of 250/ 5Amp ratio for Multifunction Meter1 Set of CTs one of 200/ 5Amp ratio for Multifunction Meter1 Set of CTs one of 125/ 5Amp ratio for Multifunction Meter1 Set of CTs one of 63/ 5Amp ratio for Multifunction Meter4 Set of Phase Indication Lamp.Bus Bar :One (1) No. 300 Amp. FP aluminimum bus bar of suitable length.One (1) No. 160 Amp. FP aluminimum bus bar of suitable length.Outgoing :Phase indication lamps on each outgoing to be provided.100 Amps FP MCCB of 25KA - 2 No63 Amps FP MCCB of 25KA - 10 No40 Amps FP MCCB of 25KA - 1 No32 Amps DP MCB of 10KA - 2 NoSPARE & SPACEPanel described as above 462 METERING PANELIncoming :1 No 100 Amp. 4P MCCB of 25KA (Ics=Icu)Breaking CapacityMetering :1 Set of CTs one of 100/ 5Amp ratio for Multifunction Meter1 Set of Phase Indication Lamp.Bus Bar :One (1) No. 120 Amp. FP aluminimum bus bar of suitable length.Outgoing :Phase indication lamps on each outgoing to be provided.63 Amps FP MCB of 10KA - 2 No32 Amps DP MCB of 10KA - 9 NoSingle Phase Energy Meter- 8 Nos.Three Phase Energy Meter- 1 Nos.SPARE & SPACEPanel described as above 463 SUBHEAD VII-TELEPHONE SYSTEM 464 S/F MODULAR BOXES, BASE & COVER PLATE :- 465 Supplying and fixingfollowing size/modules, GI box along with modular base& cover plate for modular switches in recess etc as required. 1 or 2 Module (75mm X 75 mm) 466 S/F MODULAR TYPE SWITCH / SOCKET :- 467 Supplying and fixing following modular switch/ socket on theexisting modular plate & switch box including connections but excluding modular plate etc as required. 468 Telephone socket outlet 469 TV Antenna socket outlet 470 Supplying and drawing telephone wire following pair 0.5 sqmm FR PVC insulated annealed copper conductor, unarmoured telephone cable in the existing surface/recessed steel/PVC conduit as required. 2 Pair 471 Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated,shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/recessed steel/PVC conduit as required. 472 Supplying and fixing modular blanking plate on the existing modular plate& switch box excluding modular plate as required 473 Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. 1 run of cable 474 NON SCH. 475 Supplying and fixing following modular switch/ socket on theexisting modular plate & switch box including connections but excluding modular plate etc as required. RJ-45 Jack With Cat 6 -2M 476 Supplying telephone wire following pair 0.6 sqmm FR PVC insulated annealed copper conductor, unarmoured telephone cable in the existing surface/recessed steel/PVC conduit as required. 5 Pair 477 S/f of 10 pair Junction Boxes for Floors and building with Krone connectors , with connection and punching of same 478 SUBHEAD VIII-CABLES TRAY & RACEWAY 479 Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 480 100 mm wide x 50 mm depth x 1.6 mm thickness. 481 150 mm wide x 50 mm depth x 1.6 mm thickness. 482 Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray bends (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 483 100 mm wide x 50 mm depth x 1.6 mm thickness. 484 150 mm wide x 50 mm depth x 1.6 mm thickness. 485 Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray Tee (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 486 100 mm wide x 50 mm depth x 1.6 mm thickness. 487 150 mm wide x 50 mm depth x 1.6 mm thickness. 488 Providing, Laying and Fixing following Dia RCC Pipe NP 2 Class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 ( 1 Cement : 2 fine sand)including trenching ( 75 cm) deep and refilling etc. as required. 150mm dia 489 NON SCH. 490 Providing and Laying unplastisized rigid PVC pipe conforming to IS:13592 type A including jointing , cuttingand making good the walls & floors as per requirement. 150mm 491 Supply of AC 230/250 Volts, 50 Hz exhaust fans including providing nuts, bolts, mounting frame and other accessories including connections etc. complete as required 492 300mm sweep. 493 600mm sweep. 494 Supply of AC 230/250 Volts, 50 Hz Wall fans including providing nuts, bolts, mounting frame and other accessories including connections etc. complete as required 300mm sweep. 495 Making of following size of Cable Chamber made of 230 mm thick brick work in cement mortar (1 cement : 6 sand) with PCC 100 mm thick PCC base plastering of inner and outer surface with cement mortar including providing of Heavy Duty C.I Cover complete with digging, refilling and removal of surplus soil complete as required. 900 mm x 900 mmx 1000 mm deep 496 (NON SCH) 497 Supplying, Installation and commissioning of AMF start silent type 50 KVA DG set comprising of suitable BHPdiesel engine directly coupledto 3 phase Model- 4K1080TAG2 Engine BHP-80 rated at 1500 RPM, Water Cooled, Four Stroke Electric Start 4 Cylinders Diesel Engine conforming to BS 5514 with capacity Of 10%, complete in all respects with all required safety devices, fittings, batteries, accessories, filters, residential type silencer, control panel, inbuilt diesel oil MS tank of 990 ltrs. capacity made of 2mm thick M.S. sheet complete with M.S. fuel piping, G.M. gate valves, supports, control cable between generating set and control panel, exhaust piping with asbestos roping, antivibration mounting pads, first filling of lubricant oil totally enclosed in air tight, dust proof, weather proof, powder coated cubical type, sound proof as per CPCB norms acoustic enclosure made of 2mm thick CRCA sheet with with heavy duty doors, lockable arrangement, sound proof insulation with high density rock/mineral polymer/fibre cloth and perforated CRCA sheets, suitable to reduce the sound level upto 75dba approx. at a distance of 1 mtrs. as per CPCB norms Complete with axial flow heavy duty exhaust fans for adequate ventilation exhaust of hot air etc including making of cement concrete foundation of 1: 2:4 (1 cement 2 sand and 4, 40mm graded stone aggregate) as per manufacturer recommendation complete as per specifications and conditions as required. (The diesel engine and alternator shall be so rated to deliver the specified output at site condition complete with control cable etc. as required. 498 SUBHEAD XI- Solar Photovoltaic Power Plant 499 Supply, Installation, Testing and Commissioning of ongrid Solar Photovoltaic Power Plant conforming to MNRE specifications as amended, consisting of Mono/Poly Crystal line silicon solar cells, net metering facility, necessary protections, earthing, mounted on Aluminium /GI structure of suitable strength with following components complete as required:-a)Solar Photovoltaic Module of capacity 330Wp or above,manufactured in India, conforming to IS 14286/ IEC61215, IS/IEC61730-Part-1, IS/IEC61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 16.5%. PV module sused in solar power plants /systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years.b) Power Conditioning Unit (PCU) of 350- 800 V DC Input voltage range and 400V AC, three phase, 4 wire,50Hz+/-2.5Hz, output voltage suitable to generate AC Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 degree C. The PCU shall adjust the voltage and frequency level to suit the Grid Voltage Frequency.c) Data Monitoring System complete with accessories.d) Fixing of Array junction box & Main junction box with IP65 protection and termination arrangement for incoming and outgoing cable along with glands, lugs and other accessories etc. as required.e) Lightning and surge voltage protection.f) Connections & Interconnections by supplying & fixing required size XLPE insulated copper conductor 1.1 kV grade armoured power and control cables between solar modules, main power cable to grid supply PCU unit along with supplying & fixing of necessary channel/ conduit lugs and other accessories etc. as required. 500 ESTIMATE OFFOR 4.5 Mt. WIDE C.C. ROAD 501 Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by Engineer-in- Charge etc( PWD-251) 502 Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earthwith lead upto 50 metr etc(DSR 16.1)*0.8222 503 Supplying and stacking at site. 16.3.1 90 mm to 45 mm size stone aggregate etc and Laying, spreading and compacting stone aggregate of specified sizes to WBM specifications in uniform thickness, hand picking, rolling with 3 wheeled road/vibratory roller 8-10 tonne capacity in stages to proper grade and camber, applying and brooming requisite type of screening / binding material to fill up interstices of coarse aggregate, watering and compacting to the required density .(DSR 16.3.2 and 16.4)*0.8222 504 Providing and laying design mix cement concrete of M-30 grade, in roads/ taxi tracks/ runways, using cement content as per design mix, using coarse sand and graded stone aggregate of 40 mm nominal size in appropriate proportions as per approved & specified design criteria, providing dowel bars with sleeve/ tie bars wherever required, laying at site, spreading and compacting mechanically by using needle and surface vibrators, levelling to required slope/ camber,etc(DSR 16.43.2)*0.8345 505 Providing and fixing pre-moulded joint filler in expansion joints of RCC roads / CC pavements after making the joints dust free with high pressure air jet cleaners,etc(DSR 16.45)*0.8222 506 Providing and laying in position bitumen hot sealing compound for expansion joints etc. (DSR- 16.46.1*0.8222) Using grade A sealing compound. 507 TREMIX FLOORING IN PARKING AREA 508 Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by Engineer-in- Charge etc( dsr 2.1) 509 Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earthwith lead upto 50 metr etc dsr 16.1 510 Supplying and stacking at site. 16.3.1 90 mm to 45 mm size stone aggregate etc and Laying, spreading and compacting stone aggregate of specified sizes to WBM specifications in uniform thickness, hand picking, rolling with 3 wheeled road/vibratory roller 8-10 tonne capacity in stages to proper grade and camber, applying and brooming requisite type of screening / binding material to fill up interstices of coarse aggregate, watering and compacting to the required density .(dsr16.3.2 and 16.4) 511 Providing and laying design mix cement concrete of M-30 grade, in roads/ taxi tracks/ runways, using cement content as per design mix, using coarse sand and graded stone aggregate of 40 mm nominal size in appropriate proportions as per approved & specified design criteria, providing dowel bars with sleeve/ tie bars wherever required, laying at site, spreading and compacting mechanically by using needle and surface vibrators, levelling to required slope/ camber,etc(sor 16.43.2) 512 Providing and laying in position bitumen hot sealing compound for expansion joints etc. (DSR- 16.46.1*0.8681) Using grade A sealing compound. 513 Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge). 514 [ LANDSCAPING WORK ] 515 Supplying and stacking sludge at site including royalty and carriage up to 1 km (sludge measured in stacks will be reduced by 8% for payment). 516 Carrigae of sludge upto 5 K.M. 517 Supplying and stacking at site dump manure from approved source including carriage upto 1 km (manure measured instacks will be reduced by 8% for payment) : Screened through sieve of I.S. designation 4.75 mm 518 Carrigae of manure upto 5 K.M. 519 Mixing earth and sludge or manure in the required proportion specified or directed by the Officer-in-charge. 520 Spreading of sludge, dump manure or/and good earth in requiredthickness (cost of sludge dump manure or/and good earth to bepaid separately). 521 Digging holes in ordinary soil and refilling the same with theexcavated earth mixed with manure or sludge in the ratio of 2:1by volume (2 parts of stacked volume of earth after reduction by20% : 1 part of stacked volume of manure after reduction by 8%), flooding with water, dressing, including removal of rubbish and surplus earth, if any with all leads and lifts ( cost of manure, sludge or extra good earth if needed to be paid for separately). 522 Holes 0.9 m dia. and 0.90 m deep. 523 Providing & stacking of Phoenix sylvestris Roxb. (Wild date palm/khajur) of height 150-165 cm. in Big HDPE Bag as per direction of the officer-in-charge. 524 Providing & stacking of Pinus longifolia (Pinus) of height 90-105 cm. in cement pots of size 35cm as per direction of the officer-in-charge. 525 Grassing with selection No.1 grass including watering and maintenance of the lawn for 30 days or more till the grass forms a thick lawn, free from weeds and fit for mowing including supplying good earth, if needed (the good earth shall be paid for separately). With grass Turf. 526 Sand Stone Pathway 527 Supplying & Laying of P.C.C. in 1:4:8 (1 Cement :4 Coarse sand: 8 stone aggregate 40 mm nominal size in base includinmg supply of all material labour T&P etc. 528 40 mm thick rubbed stone flooring over 20 mm (average) thick base of cement mortar 1:5 (1 cement : 5 coarse sand) with joints 3 mm thick, side buttered with cement mortar 1:2 (1 cement : 2 stone dust) admixed with pigment to match the shade of stone and pointing with same mortar. Red sand stone 529 Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge). 530 Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. 531 [ COBBLE PATHWAY ] 532 Earth work in excavation 533 Excavation by Manual means 534 Surface dressing 535 P.C.C. 1:4:8 536 B/W in 1:4 ( 1Cement :4 Coarse sand) 537 12 mm plaster in 1:3 outer 538 12 mm plaster in 1:3 inner 539 Providing & fixing Cobble Stone Flooring (10X10X10)cm filling of joints in 1:3 Cement mortarwith matching colour pigments all complete specification & direction of Engineer in charge. 540 [ ABSTRACT OF COST - CHHATRI ] 541 Boring with hydraulic piling rigs with power units, providing and installing cast in situ single under reamed piles of specified diameter and length below pile cap in M-25 cement concrete, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and the length of the pile to be embedded in pile cap etc. all complete. (Length of pile for payment shall be measured upto to the bottom of pile cap) : 300 mm dia piles 542 Excavation of foundation in ordinary soil (loam clay or sand) including lift upto 1.50 meter and lead upto 30 meter and including filling, watering and ramming of excavated earth into the trenches or into the space between the building and sides of foundation trenches or into the plinth and removal and disposal of sur-plus earth as directed by the Engineer incharge up to a distance of 30 meters from the foundation trenches. 543 Sand filling in plinth under floors including watering, ramming, consolidating and dressing complete including lead up to 50m and lift upto 1.5m and including cost of sand. 544 Providing and laying in cement concrete 1:4:8 (1 cement :4 coarse sand :8 graded Stone aggregate 40 mm nominal size) and curing complete,including cost of form- work, in foundation and floors. 545 Providing and injecting chemical emulsion for preconstructional antitermite treatment and creating a chemical barrier under and alround the column pits wall trenches basement excavation top surface if plinth filling junction of wall and floor, along the the external perimeter of binding expansion joints, surrounding of pipes and conduits etc, complete (plinth area of the building at ground floor only shall be measured as per I.S.6313(PartII 1981)Alderine emulsifiable concentrate or any other approved material such as Heptrachlor or Chlordane will be used. The rate of application of chemical emulsion shall be as follows : (1)Treatment for masonary & foundation 5 liters per sqm. (2) Back fill in immediate contact with foundation 7.5 liters/sqm (3) Treatment of top surface of plinth filling 5 liters/sqm (4) Treatment junction of wall and the floor 7.5 liters /sqm (5)Treatment of soil along external perimeter of building 7.5 liters/sqm. (6) Treatment of soil under apron along external perimter 5 liters/sqm. (As per manufacturers standard dilution) 546 R.C.C. work with cement approved coarse sand and 20 mm. guage approved stone grit im the proportion of 1:1.5:3 in lintels of doors and windows excluding supply of reinforcement and its fixing and binding the same with 24 BWG binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. strength of the concrete shall not beless than M-20. 547 As in item no. 6 above but for slabs (Using 1:1.5:3 Mix concrete). 548 As in item 6 but for thelighterbeams i.e. having spans upto 6 m. (Using 1:1.5:3 Mix concrete). 549 As in item 6 abovebut inR.C.C.Raft foundation and footingwithapproved stone ballast. (Using1:1.5:3Mix concrete). 550 As in item 6 above but in R.C.C. columns in 1:1.5:3 having strength not less than M-20. 551 M-150 brick work in 1:6 (one cement and six coarse sand of 2.25 fineness modulus) mortar infoundation & plinth including supply of all materials, labour and T & P etc required for proper completion of the work. 552 P/F Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level. 553 15 mm cement plaster on rough side of single or half brick wall of mix 1:4 (1 cement: 4 coarse sand) 554 Stone work (machine cut edges) for wall lining etc. (veneer work) upto 10 metre height, backing filled with a grout of average 12 mm thick cement mortar 1:3 (1 cement : 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade : (To be secured to the backing and the sides by means of cramps and pins which shall be paid for separately) :Red sand stone - exposed face fine dressed with roughbacking. 30 mm thick 555 Providing and fixing stainless steel cramps of required size and shape for anchoring stone wall lining to the backing or securing adjacent stones in stone wall lining in cement mortar 1:2 (1 cement : 2 coarse sand), including making the necessary chases in stone and holes in walls wherever required. 556 Supplying, fabricating, transporting, hoisting and fixing in position good quality of 70 mm Red sandstone in various elements for all levels. Stone shall be free from cracks, lines stains and even in shade for each element. The The stone shall be fine grained and reddish or buff-colored (locally available). The work shall be carried out as per attached drawings with different process of i.e carving (manual/ by machine), ornamental work, traditional work, figure work (any type, any size), CNC cutting, moulding. The carving and molding work shall be of very good quality. The stones to be fixed in line, level and plumb in all respect with the use of brass clamps, pins, (to be paid separetely) dowels, cement slurry with matching pigment and Epoxy of Akemi Germany, Ardex Endura, MYK laticrete or approved make as required and as approved by the Architects. 557 Supply/FIXINGOF Installation Of Fountain 558 [ ABSTRACT OF COST - POND (SIZE - 30.0X 3.3 MT. ] 559 Earth workinexacavationintrenches for foundations in ordinarysoil (loan clay or sand) includingliftupto 1.5m and leadup to 30m.&including filling watering & ramming of excavated earthin to trenchesorintothespace between the building& thesidesof foundation trenchesor in totheplinth and removal & disposal of surplus excavated earthas directedbytheEngineer i/c upto adistanceof 30 m fromthe foundation trenches. 560 Providing and layingin cement concrete 1:4:8 (1 cement :4 coarse sand :8 graded stone aggregate 40 mm nominal size) and curing complete,including cost ofform-work,in foundation and floors. 561 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size)(Footing) 562 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natu ral sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) 563 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level or above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. 564 Water proofing of pool as per spec.of DON building Chemicals. 565 Providing & fixing Glass Mosaic tiles in pond. 566 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite stone slab all colour and texture except black, Cherry/ Ruby red Area of slab over 0.50 sqm 567 Centering and shuttering including strutting, propping etc. and removal of form for. 568 Foundations, footings, bases of columns, etc. for mass concrete 569 Columns, Pillars, Piers, Abutments, Posts and Struts 570 Underground Sump 571 Supply installing , testing and commissioning of non clog submerssible tupe drainage/dewatering pumpset.Product Type: SUBMERSIBLE DRAINAGE PUMP Product ConfigurationPump Classification: Standard PumpComponent Materials Volute Material: Cast Iron FG 260 Impeller Material: Cast Iron FG 260Shaft Material: S.S AISI 410 Seal Material: Carbon/Ceramic/NBR/S.S 304 Motor Specifications Phase: 3 Voltage: 380-415VCable Length: Standard - 5 metresCable Length: Additional - 0 metres: 0Pipework Connection Float Switch: With Float Switch Solids Diameter LimitMaximum Solids Diameter: 10 mm Flow Rate = 205 LPM Each Pump Head = 9mEach Pump Set Detail = 1W+1S ( 2No. for LOWER GROUND TOILET) 572 Filling of carted earth. (230.13*4) 573 COST OF LIFT 13 PERSON 574 COST OF SOLAR PHOTO VOLTAIC PLANT 575 COST OF D.G.SET - 50 KVA 576 GST Extra as per applicable
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
Uttar Pradesh View Result →
20.
Public Administrative Department #9449825 Technical Bid
Tender for the work of auditorium landscaping, HVAC and PA system in the convention center under construction in sector-8 of Ram Ganga Awasiya Yojana, 1 WALL PANELING & FALSE CEILING Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main T runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross T of size 24x25 mm made of 0.30mm thick (minimum) sheet, 1200 mm long spaced between main T at 600 mm center to center to form a grid of 1200x600 mm and secondary cross T of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main T runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete forall heights as per specifications, drawings and as directed by Engineer-in-charge.GI Metal Ceiling Lay in perforated Tegular edge global white color tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/sqm (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient ) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fiber acoustical fleece. Make: Armstrong/ Sant GobainD.S.R. Item No. 12.52.2 2 Providing and installation of acoustical wall panelling wood finish Slats made out of MDF board , Melamine / veneer laminated finish, perforated wooden grooved slats (2mm grooves @ 8mm centers) / (2mm Slats @16mm pitch) / (2mm grooves @ 32mm centers) / (2mm grooves @ 64mm centers), backlined with black acoustical fleece, tongue-groove edge for a seamless look, FR grade, of lineal dimension size 128mm x 2440mm x 16mm thick having density 1000Kg /m3, weight12.8Kgs/m2 installed by using GI strut system. The GI strut system includes GI Cross channel having thickness 0.45mm, length 3600mm, knurled web 40mm, depth 10mm and equal flanges 15mm is fastened vertically/horizontally at every 600mm centers. Aluminium core cross channel having thickness 0.5mm, length 2400mm, web 15mm and 27mm, depth 18mm and flanges of 7mm with suitable edge and centre brackets is then fixed perpendicular to the cross channel with the help of fasteners at every 400mm centers. Contractor to Provide expansion joints of 3mm at every 5mts both ways. Make. Armstrong / Sant GobainAs per Ref. BOQ Item No. 1.27 3 Providing and fixing in position Auditorium High Back chairs of inner side size width (W1)490X480X1020 with push back mechanism having seat assembly made of polyuret lane oam mou ded with M.S. tubular frame insert which is upholstered with fabric. The structural should be as per technical specification as mentioned below :- Back :- Back of chair shall be 470mmX730mmX130mm upholstered constructed with 19mm thick ply having proper curvature for lumber support with PIT. moulded foam having density 40±51:g/cum, upholstered chair back to have plastic back shall duly embossed, bend and Formed by ABS. The back of chair should have provision of seat number and same will be provided by the chair supplier. Seat Chair seat size to be 480X490 with thickness of minimum 130mm with 19mm plywood this should be covered with minimum 120mm in P.U. foam, fully upholstered with P.U. moulded foam having density 45±5kg/cum.Side panels :- All side panel to be of 12mm thick plywood covered with fabric and fused with 25mm thick loam, side panel to cover all exposed metal part. The end panel of row should have provision of row number indicator with LED light. Arm rest:- 2nd class teak wood melamine Polished arm rest of size 425X.65X40mm of approved design will be fixed above side panels. Fabric :- The Fabric shall be inherent Fire Resistant Fabric, 100% Polyester Stretchable Circular knit. Fabric, of approved make , shade and design of minimum 400 GSM, quilted with foam bonded fabric of 5.0mm thick. (The shade and quality is to be finalized by Engineer-in-charge as well as by the client department.)Push back :- (A) 1. A metal sheet mechanism duly embossed of size 450X440X1.6mm. 2. Block to be 2 triangular blocks duly embossed — 300X300mm with 4 of 9mm holes. . 3. Longitudinal tubes of size 40x20x490 mm of 1.6mm thickness- with 2 tubes each and 4 longitudinal tube of size 20x6 mm duly bent in shape to shape Riveted/Welded & approximately 350 mm long. 4. Seal back Bracket interconnected/Riveted/Welded and Back Bracket to be 200X60X1.6mm. 5. Seat Bracket to have stopper cup with 5 rivets and approximately 170X340X1.5mm — 2pairs for Seat/Back. 6. All rivets to be with nylon washers and pneumatic machine only. 7. Rollers to withstand temperatures up to 200 degree and oi sizes 22mm width & 38mm Dia, duly riveted and welded supported by metal sheet of size 30mmX120mm- I Pair. 8. All stopper material to be reinforced by nylon tubes of size 30mm. 9. Metal stand to be 300X300X3mm duly bent in 1 piece supported by 3 structures 20X40X270mm each. (B ) All exposed Metal parts shall be Powder Coated with 7 Tank process of minimum 50 Microns. Rigid PVC civic shall be used to hide all dashfasteners withy Nut bolts used in chair. The chair shall be installed using suitable anchor fasteners. The sample of chair shall be got approved from Engineer-incharge as well as by client department also before making mass production. (Nu additional time shall he given for this activity.) Any minor rectification/changes in above nomenclature of auditorium chair as required by Engineer-in-charge as well as client department, the same will be accepted and adopted for execution at site of work which includes in the rate of above item. Nothing extra will be paid on this account.acceptable Make : Godrej, Mars Slider High Back W/o Desklet with PU Armtop Azure Blue Main Chair Make: Godrej Interio Market Rate 4 Providing and fixing in Auditorium Flooring and Steps - Woven vinyl carpet floorings of vinyl woven series with roll dimensions of 1.8/2mtr meters width and length of 20 meters or Tiles size as per company standard should be approved by architect. 2.50-2.80 mm thickness to laid on hard, levelled, smooth and moisture free sub floor. Woven Vinyl flooring should have traffic classification 33 and weight of 2.7-3.5 kg/m2. Flooring should have caster chair EN-985 tested with color fastness of more than 6. It should be ASTME662 qualified on Smoke density test. Product must be fire rating of the product should be Bfl-S1. Any Joints in flooring rolls should be sealed with cold welding. This work will be inclusive of all Labour, Raw Material, Hardware, adhesive etc. complete. Carpet will be provided as per approved shade and colour in Approved Makes- Vibrant Floors/Armstrong Flooring/MAC ,as per the satisfaction of the Architect and Engg. Incharge.Market Rate 5 Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc.Including providing and fixing phenolic laminated sheet cover on the fan box etc. as required.D.S.R electrical Item No. 1.35make:Schneider/Northwest 6 Numbering of ceiling fan/ exhaust fan/ fluorescent fittings as required. make:Schneider/NorthwestD.S.R electrical Item No. 1.49 7 Providing and fixing circular/Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/M.S. sheet box by means of 3.3 mm dia round headed screwed, one loc at the conrners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing.D.S.R electrical Item No. 14.15 8 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Disect Current(BLDC) motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value(CM/M/W) minimum 6, Air delivery minimum 210 Cum/Min, 350 RPM(tolerance as per IS: 374-2019), THD less than 10% remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise= 75 degree C(max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.D.S.R electrical Item No. 19.1make: Bajaj/Havells/Crompton 9 2 thick Slotted Wood Finish Wall Panel system on Masonry: Providing and fixing wall panelling on existing masonry with 50mm x 50mm Aluminium section framework of size 600mmx600mm grids and filled with acoustical insulation of 50 mm thickness 1000 gsm density from Star Insulation or Prime Insulation. The framework and acoustical infill is to be concealed behind the 15mm Slotted finish fire rated wood finish MDF panels from Topakustik, Wood Fit, Armstrong, Sound Slats, RPG or equivalent approved vendors. The perforated wood finish panels must have a minimum perforation area of 12% or higher and is to be supplied with black RP Tissue or equivalent of approved quality. This should be completed as per details and diagrams provided. Rate shall be inclusive of installation on the frame work arrangements. Works will be inclusive of scaffolding and staging at all levels. Rate shall include the preparation of detailed shop drawings as per site conditions, which shall be approved beforecommencement of worksMake : Armstrong/ Saint GobainAs per Ref. BOQ Item No. 1.26 10 ACOUSTIC DOOR WITH CHOWKHAT FOR DOOR OPENING SIZE 1.50M X 2.1M:Providing, Supplying, Installation, Testing and fixing in position a 65 mm thick acoustic door with chowkhat. Door should have a 150 mm x 300 mm vision panel of6.0 mm thick toughened glass. Both Shutters shall be made with 100mm x 50mm thick hardwood outer frame with 50 mm x 50 mm hardwood ribs at 500 mm c/cbothways. All woodwork shall be treated with anti-termite treatment. The door shutter shall have 6 mm thick BWP grade plywood fixed on its both sides. All the cavities inside the door shall be filled with high NRC acoustic insulation materials (rockwook of 60 kg/m3 density) Insides of the door will be lined with 3mm thick MLV Sheet of minimum 1700 kg/m3 density. Periphery of the the shutter shall be covered with 12mm thick teakwood lipping matching with the door frame. The external faces of the door shutter will be finished with 1mm thick laminate on both sides. Teakwood lipping will be melamine polished. Weather seal of Rehau make shall be fixed on the door frame to fill the gap of shutter and wooden frame. Drop down seal to be fixed in shutter to block the gap with floor when the door is closed. The cost shall include all hardware fittings like heavy duty SS Hinges ( 4inch long - 5 per door) , 1ft long D type SS 304 Handles of Godrej/Hettich/Dorma make ( both inside and outside).Make: GodrejAs per Ref. BOQ Item No. 1.19 11 Providing and fixing Godrej Kaditala 275 mm ChromeMake: GodrejAs per Ref. BOQ Item No. 1.20 12 Providing and fixing hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, for door weight upto 80 kg to 100 kg and door width from 750 mm to 900 mm), with double speed adjustment with necessary accessories and screws etc. complete.Make: GodrejAs per Ref. BOQ Item No. 1.21 13 Providing and Supplying factory made Podium table 8ft long x 2ft deep x 2.5ft high made with 25mm thick prelaminated HDF Board (all full round edges) with full Vanity panel on three sides and 3 internal vertical division panels of 1ft x 2.5ft for seating 3 persons on the TABLE. The design and color of the table will be as approved by the authorities.The table will have provision for fixing electrical points.The table will have provision for 8 Way LEGRAND POP-UP Box forDATA/HDMI/ELEC. points. Make : Legrand/SchneiderAs per Ref. BOQ Item No. 3.02 14 Providing and Supplying Podium Chairs ( Mid Back without wheels) of design and color approved by college authorities Make: Godrej/ Featherlite/ Geeken/ Durian MakeAs per Ref. BOQ Item No. 3.03 15 Providing and Fixing PVC Wall Paneling with all complete fitting Make : Armstrong/GyprocMarket Rate 16 Supplying of following LED fitting on recess/surface made of metallic CRCA powder coated steel / aluminium body, minimum system efficacy 100 Lumens/watt. Electronic in buit driver, PF>0.9, suitable for 220V-240V 50Hz A.C. supply, in the existing false ceiling with S.S. chain hanging arrangements/ on surface as per site condition including making connections with 3x1.5sq.mm FRLS copper conductor cable in steel flexible pipe, testing and commissioning etc. required.SITC of Step light Colour: Anthracite grey Material Aluminum Dimensions 201 x 91 x 35 Lamp Base LED IntegratedWattage 5W ( (Equivalent to Philips Model No. B07LH1FXLR)As per Ref. BOQ Item No. 2.26 17 Supplying of following dimmable LED fitting on recess/surface made of metallic CRCA powder coated steel / aluminium body, minimum system efficacy 100 Lumens/watt. Electronic in buit driver, PF>0.9, suitable for 220V-240V 50Hz A.C. supply, in the existing false ceiling with S.S. chain hanging arrangements/ on surface as per site condition including making connections with 3x1.5sq.mm FRLS copper conductor cable in steel flexible pipe, testing and commissioning etc. required. SITC of Recessed mounted 24 watt LED down lighter made up of high pressure die cast aluminium housing complete as required. (Equivalent to Lighting Technologies,MAke : Philips,Bajaj ) As per Ref. BOQ Item No. 2.25 18 Supplying of following LED fitting on recess/surface made of metallic CRCA powder coated steel / aluminium body, minimum system efficacy 100 Lumens/watt. Electronic in buit driver, PF>0.9, suitable for 220V-240V 50Hz A.C. supply, in the existing false ceiling with S.S. chain hanging arrangements/ on surface as per site condition including making connections with 3x1.5sq.mm FRLS copper conductor cable in steel flexible pipe, testing and commissioning etc. required. Supply of 1200 mm long 20 watt LED luminiare (Make : Philips,Bajaj, Havelles LUMILINEPLUSBS20WLED865SPCSS)As per Ref. BOQ Item No. 2.27 19 Installation, Testing and Commissioning of BAJAJ single LED Signage BESL 03 LED SSD WBB GREEN above the exit doors of the auditorium including providing fixing neccassry base plate , point wiring, fitting fixture etc. complete.MAke : Philips/Bajaj As per Ref. BOQ Item No. 2.28 20 Supply installation testing of LEGRAND 8 WAY Conference Table POP UP BOX, with power , Lan , HDMI, Audio ,CGA & USB including all necessary associated hardware . Make : Legrand/SchneiderAs per Ref. BOQ Item No. 2.29 21 Trenching in ordinary soil up to a depth of 60 cm including removal and stacking of serviceable materials and then disposing of surplus soil, by spreading and neatly levelling within a lead of 50 m and making up the trenched area to proper levels by filling with earth or earth mixed with sludge or / and manure before and after flooding trench with water (excluding cost of imported earth, sludge or manure).2.1 (dsr hort. 2020) 22 Supplying and stacking of good earth at site including royalty and carriageupto 5 km lead complete (earth measured in stacks will be reduced by20% for payment).2.2 (dsr hort. 2020) 23 Supplying and stacking sludge at site including royalty and carriage upto 5km lead complete (sludge measured in stacks will be reduced by 8% forpayment).2.3 (dsr hort. 2020) 24 Supplying and stacking at site dump manure from approved source,including carriage upto 5 km lead complete (manure measured in stackswill be reduced by 8% for payment) :2.4.1 (dsr hort. 2020) Screened through sieve of I.S. designation 20 mm 25 Supply & plantation of Trees upto 8ft to 10ft height well settled, all indigenous varieties (local) as per listed below, location and quantities shall be as per drawingMangifera Indica (Mango), Bacopa Monnieri (Brahmi), Terminalia Tomentosa (Asna), Azadirachta Indica (Neem) & Bambusa Bambos (Baans)Terminalia Arjuna (Arjun), Tectoria Grandis (Sagaun), Shorea Robusta (Saal), Stereospermum Tetragonum (Padal), Anogeissus Latifolia (Bakli), Madhuca Longifolia (Mahua) & Diospyros Malabarica (Gaub) Saraca asoca (ashok), Ficus religiosa (peepal), Ficus benghalensis (bargad), Aegle marmelos (bel) & Phyllanthus emblica (aonla) Pterocarpus Santalinus (rakta chandan), Butea monosperma (dhaak), Artocarpus altilis (kathal) & Santalum album (chandan) Saraca Asoka (Sita Ashok), True Cinnamon (Nag Kesar), Mangolia Champaca (Champa) & Mimusops Elengi (Maulsari) Saussurea Ggossypiphora (Mratyusanjeevani), Azadirachta Indiac (Neem) & Adiantum Venustum (Hansraj) 26 Anti termite treatment of lawn area through premise 30.50% I P. one liter premise diluted [email protected] litresolutionpersqmlawnorbedarea. (two application) i/c cost of chemical) and as per direction of officer-in-charge.and as per directionof officer-in-charge.2.56 (dsr hort. 2020) 27 Providing and laying Neelgiri/Mexican grass turf with earth 50mm to 60mm thickness of existing ground prepared with proper level and ramming with tools wooden (Dhurmos) and than rolling the surface with light roller make the surface smoothen and light waterning with sprinkler and maintenance for 30 days or more till the grass establish properly, as per direction of officer-in-charge.2.33 (dsr hort. 2020) 28 Preparation of beds for hedging and shrubbery by excavating 60 cm deep and trenching the excavated base to a further depth of 30 cm, refilling the excavated earth after breaking clods and mixing with sludge or manure in the ratio of 8:1 (8 parts of stacked volume of earth after reduction by 20%: one part of stacked volume of sludge or manure after reduction by 8%), flooding with water, filling with earth if necessary, watering and finally fine dressing, leveling etc. including stacking and disposal of materials declared unserviceable and surplus earth by spreading and leveling as directed, within a lead of 50 m, lift up to 1.5 m complete (cost of sludge, manure or extra earth to be paid for separately) 2.13(dsr hort. 2020) 29 Supplying and stacking of well decayed cattle manure at site including royalty and carriage upto 5 k.m.lead complete (Cattle manure measured in stacks will reduced by 8% for Payment).2.25 (dsr hort. 2020) 30 Providing and stacking of plant Mogra of height 25 to 30 cm., 2 to 3 branch in earthen pots of size 20 cm Earthen Pot/Plastic Pot and as per direction of the officer-in-charge. 4.88(dsr hort. 2020) 31 Providing and Displaying Budded Rose (H.T. variety) 3 to 4 healthy branch 30 cm and above ht. well developed with one and above flower plant in 20 cm Earthen Pot, as per direction of the officer-in-charge. 4.91(dsr hort. 2020) 32 Providing and Displaying Cycus cirsnallis well developed with fresh & healthy 35 to 40 lush green leaves in 40 cm Cement Pot as per direction of the officer-in-charge. 5.13(dsr hort. 2020) 33 Providing and Displaying Cyprus golden well shaped developed with good colored foliage fresh & healthy 60 to 75 cm ht in 30 cm Earthen Pot as per direction of the officer-in-charge. 5.17(dsr hort. 2020) 34 Providing and Displaying Ficus Starlight with fresh, healthy and attractive foliage 45 to 60 cm spread 75 to 90 cm ht., specimen bushy ,in 35 cm Cement Pot as per direction of the officer-in-charge. 5.28(dsr hort. 2020) 35 Providing and stacking of Alpinia Variegated (three in one) having ht. 30 cm and above, with fresh and healthy variegated foliage in 25 cm size of Earthen Pot/Plastic Pot & as per direction of the officer-in-charge. 6.1 (dsr hort. 2020) 36 Providing and stacking of Asparagus marrie, well developed 15 to 20 leaves, full of branches and foliage in 25 cm size of Earthen Pot/Plastic Pot & as per direction of the officer-in-charge. 6.3 (dsr hort. 2020) 37 Providing and stacking of Cuphea chinensis of ht. 20-30 cm full of branches and healthy foliage in 15 cm size of Earthen Pot/Plastic Pot & as per direction of the officer-in-charge. 6.10 (dsr hort. 2020) 38 Providing and stacking of Euphorbia milli hybrid variety, having ht. 30 cm to 45 cm with multi branch, full bloom, fresh and healthy leaves in 30 cm size of Earthen Pot/Plastic Pot & as per direction of the officer-in-charge.6.14 (dsr hort. 2020) 39 Providing and stacking of Ophiopogon jaburan (variegated) ,full of variegated leaves in Earthen Pot/Plastic Pot of size 20 cm. as per direction of the officer-in-charge. 6.21 (dsr hort. 2020) 40 Providing and stacking of Alstonia scholaris of height 150-165 cm. in bagof size 25 cm as per direction of the officer-in-charge. 7.4 (dsr hort. 2020) 41 Providing and stacking of Bauhinia purpurea (Kachnar) of height 150-165 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge. 7.8 (dsr hort. 2020) 42 Providing and stacking of Butea frondosa (Flame of Forest) of height 60-75 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge.7.13 (dsr hort. 2020) 43 Providing and stacking of Cassia siamea of height 150-165 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge. 7.17(dsr hort. 2020) 44 Providing and stacking of lotus flower of height 150-165 cm. in bag of size 25 cm as per direction of the officer-in-charge. Mr 45 Providing and stacking of Bauhinia tomentosa (yellow) of height 60-75 cm. in earthen pots of size 20 cm as per direction of the officer-in-charge. 8.2(dsr hort. 2020) 46 Providing and stacking of Calliandra hybrida of height 105-120 cm., well branched, bushy in big size HDPE bag as per direction of the officer-in-charge.8.7(dsr hort. 2020) 47 Providing and stacking of Cassia laevigata of height 45-60 cm. in earthenpots of size 20 cm as per direction of the officer-in-charge. 8.11(dsr hort. 2020) 48 Providing and stacking of Chandni dwarf of height 15-20 cm., well branched in earthen pots of size 20 cm as per direction of the officer-in-charge. 8.14(dsr hort. 2020) 49 Providing and stacking of Nyctanthes arbor-tristis (Hasingar) of ht. 90-105 cm in Earthen pots of size 20 cm as per direction of the officer-in-charge. 8.54(dsr hort. 2020) 50 Providing and stacking of Allamanda violacea of height 30 cm to 45 cm. in poly bag of size 20 cm as per direction of the officer-in-charge. 9.2(dsr hort. 2020) 51 Providing and stacking of Clerodendrum thomsoniae of height 30 cm.to 45 cm in 20 cm size of poly bag & as per direction of the officer-in-charge.9.6(dsr hort. 2020) 52 Providing and stacking of Vernonia elaegnifolia (curtain creeper) plant of height 30 cm to 45 cm. in 20 cm size of Earthen pots / Plastic pots & as per direction of the officer-in-charge. 9.14(dsr hort. 2020) 53 Providing and Stacking of Anjeer of height 75-90 cm. in poly bagsof size 25 cm as perdirection of the officer-in-charge. 11.1(dsr hort. 2020) 54 Providing and Stacking of Satavari, well developed in earthen pot of size 20 cm as per direction of theofficer-in-charge. 11.6(dsr hort. 2020) 55 Providing and Stacking of Sarpgandha well developed in poly bag of size 20 cm as per direction of theofficer-in-charge.11.14(dsr hort. 2020) 56 Providing and Stacking of Aprajita Blue well developed in poly bag of size 20 cm as per direction of the officer-in-charge.11.17(dsr hort. 2020) 57 Providing and Stacking of Aprajita White well developed in poly bag of size 20 cm as per direction of the officer-in-charge.11.18(dsr hort. 2020) 58 IRRIGATION SYSTEMDRIP IRRIGATION SYSTEM FOR PLANTATION - ASYSTEM HEAD UNIT SNAD FILTER + BACKWASH ASSLY 2.5Make : Astral/FinolexP.S. 59 SCREEN FILTER 2.5Make : Astral/FinolexP.S. 60 ASSLY FOR FILTER 2.5Make : Astral/FinolexP.S. 61 PRESSURE GAUGE + STOP COCKMake : Astral/FinolexP.S. 62 PRV Make : Astral/FinolexP.S. 63 NRV Make : Astral/FinolexP.S. 64 NETWORK- FINOLEX HDPE & PVC PIPESMake : Astral/FinolexHDPE PIPE 75 MM PN4 (TANK TO PLOT)P.S. 65 PVC PIPE 75 MM 4KG/CM2Make : Astral/FinolexP.S. 66 PVC PIPE 63 MM 4KG/CM2Make : Astral/FinolexP.S. 67 EMITTING SYSTEMMake : Astral/FinolexFINOGOL PLAIN LATERAL 16 MMP.S. 68 DRIPPER 8 LPH Make : Astral/FinolexP.S. 69 START TO END SET FOR DRIP LINE 16 MMMake : Astral/FinolexP.S. 70 BARBED COUPLER 16 MMMake : Astral/FinolexP.S. 71 TEE 16 MMMake : Astral/FinolexP.S. 72 ELBOW 16 MMMake : Astral/FinolexP.S.. 73 ELBOW 16 MMMake : Astral/FinolexP.S.. 74 BALL VALVE 63 MMMake : Astral/FinolexP.S. 75 FLUSH VALVE 63 MMMake : Astral/FinolexP.S. 76 VALVE BOX 12Make : Astral/FinolexP.S. 77 Pump: Crompton Greaves 10.00 Hp pumpwith necessary accessories.(Market Rate) P.S. 78 Providing and fixing H.D.P. container Syntex or alike one piece moulded water tank made out of low density polythyler and built corrugation including of delivery upto destinatin hoisting and fixing of accessories such as inlet,outlet over flow of all tanks capacity above 1000 to 20,000 litresMake : Astral/FinolexD.S.R. 18.48 79 Water tank platform& ShedExcavation for roadway in earth, soil of all sorts, sand, gravel or soft murum including dressing section to the required grade, camber and side slopes and conveying the excavated materials with all lifts upto a lead of 50m. and spreading for embankment or stacking as directed. By Manual Means. (with prior permission of S.E.)D.S.R. Item No. 2.2.1) 80 Providing & laying cement concrete1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)D.S.R. Item No. 4.1.8 81 Providing and laying Cast in situ/Ready Mix cement concrete in M15 of trap/ granite/quartzite/gneiss metal for bed blocks, foundation blocks and such other items including bailing out water, Steel centering, formwork, laying/ pumping, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.), with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)D.S.R. 4.20.1.2 82 Providing and laying in situ /Ready Mix cement concrete M-20 of trap / granite /quartzite/ gneiss metal for R.C.C. work in foundations like raft, strip foundations, grillage and footings of R.C.C. columns and steel stanchions etc. including bailing out water, Steel centering formwork, laying/pumping cover blocks, compaction and curing roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel) etc. complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)D.S.R.4.20.1.3 83 Providing and fixing in position TMT - FE - 500 bar reinforcement of various diameters for R.C.C. pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete.D.S.R. Item No. 5.22.1 84 Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with :Cement mortar 1:6 (1 cement : 6 coarse sand)D.S.R. 7.1.1 85 Random rubble masonry with hard stone in superstructure above plinth level and upto floor five level, including leveling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) at window sills, ceiling level and the like. Cement mortar 1:6 (1 cement : 6 coarse sand)D.S.R. 7.2.1 86 Pointing on stone work with cement mortar 1:3 (1 cement : 3 fine sand) :13.33.1 Flush/ Ruled pointing sqm 87 Providing and fabricating structural steel work in rolled sections like joists, channels, angles, tees etc. as per detailed design and drawings or as directed including cutting, fabricating, hoisting, erecting, fixing in position making riveted / bolted /welded connections without connecting plates, braces etc. and including one coat of anticorrosive paint and over it two coats of oil painting of approved quality and shade etc. complete.SHS 60x60x3 Column (5.34Kg/mtr)ISA 40X40X3 (1.83 Kg/mtr)Cleat ( 35X35X3)Base Plate ( 200x200x6)(7850 Kg/Cum)Top Plate ( 200x200x6)D.S.R. 10.20 88 Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces),D.S.R. Item No. 12.1.1 89 Supplying, installation, testing & commissioning of 6 zone, voice alarm controller with USB, MP3 player (including 6 zone button paging station) with seamless integration facility with main fire alarm panel for voice evacuation complete asrequired. Make: Bose/D&B AudiotechnikD.S.R. Item No. 17.3.1 (Electrical) 90 Supplying, installation, testing & commissioning of 1.5/3/6W ceiling speaker complete as required.Make: Bose/D&B AudiotechnikD.S.R. Item No. 17.3.2 (Electrical) 91 Supplying, installation, testing & commissioning of 1.5/3/6W metal box ceiling/wall speakers complete as required.Make: Bose/D&B AudiotechnikD.S.R. Item No. 17.3.3 (Electrical) 92 Supplying, installation, testing & commissioning of ceiling/wall mounted loud speaker, 3/1.5 Watt in ABS enclosure complete as required.Make: Bose/D&B AudiotechnikD.S.R. Item No. 17.3.4 (Electrical) 93 Supplying, installation, testing & commissioning of 6 inches dia, 2 watts, 70/100 volts ceiling speaker complete as required.Make: Bose/D&B AudiotechnikD.S.R. Item No. 17.3.5 (Electrical) 94 Supplying, installation, testing & commissioning of digital audio amplifier 50 Watt, 25V rms operating at 240 volt ACsupply complete as required. Make: Bose/D&B AudiotechnikD.S.R. Item No. 17.3.6 (Electrical) 95 Supplying, installation, testing & commissioning of digital audio amplifier 75 Watt, 25V rms operating at 240 Volt AC Supply complete as required. Make: Bose/D&B AudiotechnikD.S.R. Item No. 17.3.7 (Electrical) 96 Supplying, installation, testing & commissioning of exit point directional sound speaker with voice and integral audio amplifier with selectable sound pulse patterns complete as required. Make: Bose/D&B AudiotechnikD.S.R. Item No. 17.3.8 (Electrical) 97 Supplying, installation, testing & commissioning of Voice command keypad 6 zone, with microphone assembly complete as required.Make: Bose/D&B AudiotechnikD.S.R. Item No. 17.3.9 (Electrical) 98 Supply, installation, testing and commissioning of 25 mm Outer dia CPVC PIPE with end caps including making air sampling opening of appropriate dia on appropriate interval and all accessories as required,(rate for area protected in sqm).Make : Astral/FinolexD.S.R. Item No. 17.4.1 (Electrical) 99 Supplying & laying of 2x1.5 sqmm fire survival armoured cable, 600/1000V rated with annealed copper conductor having glass mica fire barrier tape covered by an extruded layer of Cross Linkable Ethylene Propylene Rubber (EPR) insulation and LSZH inner bedding, steel wire armouring & LSZH outer sheath complete as required.D.S.R. Item No. 17.5.1 (Electrical) 100 Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required.D.S.R. Item No. 17.5.2 (Electrical) 101 Supplying and drawing of cable Fire Retardant PVC insulated copper conductor cable in the existing surface / recessedsteel conduit of following pairs, cores and size including connections and interconnections etc. as required.Speaker cable Single pair, 2-core, 1.5 sqmmD.S.R. Item No. 17.5.3.1 (Electrical) 102 Speaker cable Two pair, 2-core, 1.5 sqmmD.S.R. Item No. 17.5.3.2 (Electrical) 103 Speaker cable Three pair, 2-core, 1.5 sqmmD.S.R. Item No. 17.5.3.3 (Electrical) 104 Speaker cable Four pair, 2-core, 1.5 sqmmD.S.R. Item No. 17.5.3.4 (Electrical) 105 Supplying and fixing 25 mm dia MS flexible pipe with PVC coating along with all ancillaries and accessories like coupleretc. as required.D.S.R. Item No. 17.5.4 (Electrical) 106 AUDIO , VIDEO & LIGHTING WORKSSITC of Main FOH speaker having 12 inch woofer or better, min. 1.5-inch Compression driver ; Frequency Response : 82Hz-18kHz or better; Nominal Dispersion : 90° H x 60° V or better ; Power handling capacity : 250W or better; Nominal Impedance : 8O; Max SPL: 125 dB or better; Polyproylene enclosure, powder-coated finish; complete with all standard accessories as required.Make: Philips, Sony or JVRRate as per Ref. BOQ Item No. 6.01 107 SITC of Mounting/ Hanging arrangement of speaker complete with all standard accessories as required. Heavy duty Powder coated MS frame /Bracket fixed with SS Dash Fasteners of HILTI / FISHER MakeMake: Bose/D&B AudiotechnikRate as per Ref. BOQ Item No. 6.02 108 SITC of Active Subwoofer having 18 single driver; Frequency Response : 47Hz- 105Hz or better; Max SPL (Peak) : 132dB or better; Power handing capacity : 1200W or better; complete with all standard accessories as requiredMake:Philips, Sony or JVRRate as per Ref. BOQ Item No. 6.03 109 SITC of Active Stage Monitor Speaker System having 12 single driver; Frequency Response : 65Hz - 18kHz orbetter; Max SPL (Peak) : 126dB or better; Power handingcapacity : 1000W or better; complete with all standardaccessories as required.Make: Philips, Sony or JVRRate as per Ref. BOQ Item No. 6.04 110 SITC of Dual-channel professional amplifier with 2 inputchannel, should have power output of 2x 350W @8O and2 x 660W @4O or better; Should have power outputBridged mode 2000W @4O Should have Frequencyresponse: 10Hz- 21kHz or better; Total harmonicdistortion (THD): =0.05% or better; Channelsperation(Crosstalk): = -80 dB or better, S/N ratio >104dB or better, Built-in DSP feature complete with allstandard accessories as required. (Dynacord/Bose/Powersoft)Make: Bose/D&B AudiotechnikRate as per Ref. BOQ Item No. 6.05 111 SITC of Loudspeaker Management System 2 x 6 loudspeaker management system having 2x line inputs, 6x balanced outputs, input impedance > 50k O or better, CMRR: >45dB or better, Max. output level +22dBu or better, A/D performance Dynamic range >112dB Aweighted and D/A performance- Dynamic range 110dB Un- weighted or better complete with standard accessories as required.Make: Bose/D&B AudiotechnikRate as per Ref. BOQ Item No. 6.06 112 SITC of 16 channel analog mixer with 8 mic/line input or better & 2 stereo output or better; 2 or better group buses; 3 or better AUX / FX send, Frequency response : 20Hz- 20kHz or better; Phantom power : 48V or better; THD : 0.03% or better; complete with all standard accessories.Make: Bose/D&B AudiotechnikRate as per Ref. BOQ Item No. 6.07 113 SITC of Wireless Handheld microphone with Frequency response : 60Hz - 14kHz or better; Bandwidth: 24MHz; Total harmonic distortion (THD) : < 0.9%; Signal to noise ratio : > 103 dB; Pattern : Cardioid; Microphone type: dynamic; RF Power : 10mW or better; Operating time : 8 hours or better complete with all standard accessories.Make: Bose/D&B AudiotechnikRate as per Ref. BOQ Item No. 6.08 114 SITC of Wireless Lavalier microphone with Frequency response : 60Hz - 14kHz or better; Bandwidth: 24MHz; Total harmonic distortion (THD) : < 0.9%; Signal to noise ratio : > 103 dB; Pattern : Omnidirectional; Microphone type: Condenser; RF Power :10mW or better; Operating time : 8 hours or better complete with all standard accessories. Make: Bose/D&B Audiotechnik(Shure /Sennheiser/ Clock Audio / ElectroVoice)Rate as per Ref. BOQ Item No. 6.09 115 SITC of Wired handheld microphone with Frequency response : 50Hz - 16kHz or better; Pattern : Cardioid; Microphone type: Dynamic; Rugged metal housing; Sensitivity : 2.7mV/Pa or better, complete with all standard accessories. Make: Bose/D&B Audiotechnik(Shure /Sennheiser/ Clock Audio / ElectroVoice)Rate as per Ref. BOQ Item No. 6.10 116 SITC of CD player complete with all standard accessories(Gemini/LG/Panasonic/Sony)Rate as per Ref. BOQ Item No. 6.11 117 SITC of 4 Point XLR Junction Box complete with all standard accessoriesRate as per Ref. BOQ Item No. 6.12 118 SITC of 2 core 2.5 sqmm Speaker Cable complete with all standard accessoriesRate as per Ref. BOQ Item No. 6.13 119 SITC of 2 core PVC insulated Microphone Cable complete with all standard accessoriesRate as per Ref. BOQ Item No. 6.14 120 SITC of Connector & Patch Cords complete with all standard accessoriesRate as per Ref. BOQ Item No. 6.15 121 SITC of 9U Equipment Rack for housing all rack mountable equipments with internal wiring, front glass door; heat dessipation fans; movement wheels, power distributionunits etc. complete with all standard accessoriesRate as per Ref. BOQ Item No. 6.16 122 SITC of 6000 lumens laser Projector with 0.67 DMD technology or better; Contrast ratio (Native): 2,000:1 or better; Resolution : WUXGA or better; Inputs : 2 x HDMI or better, 1 x VGA or better, 1 x HDBaseT or better, 2x Audio in, 1x Mic in, 1x Audio out(3.5mm jack). Should have Horizontal & Vertical Keystone correction ±30°; should have 10-bit color display; Control : RS232 etc. complete.Make: PanasonicRate as per Ref. BOQ Item No. 6.17 123 SITC of Mounting/hanging arrangement of Projector complete with all standardaccessories.Rate as per Ref. BOQ Item No. 6.18 124 SITC of 150 motorized projection screen with 16:10 aspect ratio complete with all standard accessories (Somfy motor)Rate as per Ref. BOQ Item No. 6.19 125 SITC of Wall Plate type transmitter & Receiver extender with 1 x HDMI or better, 1 x VGA with audio input (Tx) or better, 1 x Twisted Pair output (Tx) or better; 1 x Twisted Pair Input (Rx) or better, 1x HDMI output(Rx) or better; transmission range :70 meter or better; Auto-switching between inputs; Supports computer and video resolutions up to 4K or better; Max Data rate : 10.2 Gbps or better; HDCP 1.4 or better compliant; complete with all standard accessories.Make :Extron/Crestron/Lightware / Liberty AV)Rate as per Ref. BOQ Item No. 6.20 126 SITC of 1.8 meter HDMI-HDMI Cable complete with all standard accessories.(Make: Belden/ Kramer / Liberty AV)Rate as per Ref. BOQ Item No. 6.21 127 SITC of 1.8 meter VGA-VGA with audio Cable complete with all standard accessories.(Make: Belden/ Kramer / Liberty AV)Rate as per Ref. BOQ Item No. 6.22 128 SITC of of Twisted Pair Cable complete with all standard accessories6.23 129 SITC of 100W High Quality LED Parcan Light complete with, Lamp source 3200K CCT Colour temperature CRI & TLCI Values above 95 COB LED source from Citizen/ Philips/ Osram/ Cree or reputed make (LM80 to be provided) DmX 512 dimming with 3 channel control Beam Angle of 9° / 25° / 45° Total Power Consumption of 165W High quality output replacing 1000W Halogen Par Flicker Free 100% for Tv & Film Cameras 11.7KHz Refresh Rate, Linear Dimming 0 ~ 100% Fuse and Internal safety protections Strobe option Adjustable 1~25 times/Sec Variable Fixture provided with Yoke of Manual Adjustment5 Pin XLR for DmX , Black powder coated body. RDM Control options with latest technology (RDM ID to be specified) Certification having BIS compliant to IS 10322 (Part 5/ Sec 1):2012 CE Certification compliant to EN60598-1:2015,EN61437-2-13:2014 LM79 Certificates from NABL Acrediated laboratory. Brand embosed impact on the light body for genuine product.(Make: Bajaj/Leksa Lighting / Kenson Solace / Aultra Lighting / Canara)Rate as per Ref. BOQ Item No. 6.24 130 SITC of 200W LED Profile Spot 19 Degree Light complete with, 3200K CCT Colour Temperature COB LED source from Citizen/ Philips/ Osram/ Cree or reputed make (LM80 to be provided) CRI & TLCI above 95, Strobe option Adjustable 1 ~ 25 times/Sec 4 Kinds of dimming curves, Black finish housing, Manual Focus with 4 Beam shaping cutters Efficient and well-designed Lamp reflector Efficient Copper tube based Heat Sink for Heat Dissipation Sleek and Unique Designed Light weight body Fixture provided with Yoke of Manual Adjustment DmX512 dimming with 1 or 3 Channel modes IP20 protection having Lux @ 3 Mtrs above 12040 suitable to illuminate the keypresentor or talent on stage. RDM Control options with latest technology (RDM ID to be specified) Certification having BIS compliant to IS 10322 (Part 5/ Sec 1):2012 . CE Certificationcompliant to EN60598-1:2015, EN61437-2-13:2014 LM79 Certificates from NABL Acrediated laboratory. Brand embosed impact on the light body for genuine product (eksa Lighting / Kenson Solace / Aultra Lighting / Canara)SITC of 200W LED Profile Spot 19 Degree Light complete with, 3200K CCT ColourTemperature COB LED source from Citizen/ Philips/ Osram/ Cree or reputed make (LM80 to be provided) CRI & TLCI above 95, Strobe option Adjustable 1 ~ 25 times/ Sec 4 Kinds of dimming curves, Black finish housing, Manual Focus with 4 Beam shaping cutters Efficient and well-designed Lamp reflector Efficient Copper tube based Heat Sink for Heat Dissipation Sleek and Unique Designed Light weight body Fixture provided with Yoke of Manual Adjustment DmX512 dimming with 1 or 3 Channel modes IP20 protection having Lux @ 3 Mtrs above 12040 suitable to illuminate the keypresentor or talent on stage. RDM Control options with latest technology (RDM ID to be specified)Certification having BIS compliant to IS 10322 (Part 5/ Sec 1):2012 . CE Certificationcompliant to EN60598-1:2015, EN61437-2-13:2014LM79 Certificates from NABL Acrediated laboratory.Brand embosed impact on the light body for genuine product(Make: Bajaj /Philips/ eksa Lighting / Kenson Solace / Aultra Lighting / Canara)Rate as per Ref. BOQ Item No. 6.25 131 SITC of 54 x 3W LED Par Light RGBW, Beam Angle 25° complete with LED source from Lumiled / Seoul / Nichia or reputed make (LM80 to be provided) (Leksa Lighting / Kenson Solace / Aultra Lighting / Canara) RGBW 3W Lamp source x 54 Pcs DmX 512 dimming with 8 Channel High Bright Red, Green, Blue, White LED’s Source Unlimited Color Mixing through DmX 0 ~ 100% Linear dimming , In built presets for different colors Strobe Mode 20 times/Sec Data DmX through 3 / 5 PinXLR’s 65dB ~ 130dB Sound sensing capacity Power In and Out Connections High precision colors, IP20 protectionPowder coated Black finish housing Having Sound Control & Master Slave Auto Run Mode Illuminate the Indoor stage with unlimited colour effects Rigidly built pressure die-casted Aluminium body.RDM Control options with latest technology (RDM ID to be specified) Certification having BIS compliant to IS 10322 (Part 5/ Sec 1):2012 CE Certification compliant to EN60598-1:2015, EN61437-2-13:2014 LM79 Certificates from NABLAcrediated laboratory. Brand embosed impact on the light body for genuine product. Make: Bajaj/PhilipsRate as per Ref. BOQ Item No. 6.26 132 SITC of Light fixture mouting clamp Customized for suspending on fixed bars on stage Made up of Aluminium Die casted MS threaded T bolt with yellow passivation finish Complete with black powder coating matt black finish. Safeworking load 150 KG Suitable to Batten of size 30 OD to 60 OD (Make: Leksa Lighting / Kenson Solace / Aultra Lighting / Canara)Rate as per Ref. BOQ Item No. 6.27 133 SITC of Light Fixture dual safety Chain made up of GI wire rope Bundled and twisted together Having load bearing capacity above 200 Kgs Sleve on the rope. CarabinerClip(Make: Leksa Lighting / Kenson Solace / Aultra Lighting / Canara )Rate as per Ref. BOQ Item No. 6.28 134 SITC of Fixed on stage Lighting bar/winch of 6 Mtr length constructed with an single contruction light bar Made out of 48mm Outer Dai, 40 Nominal Bore, Mild Steel Pip It shall be hanged from the roof to accommodate various type of stage light fittings. It should hang from the roof with MS angle which is suspended from the fish plate of 5mm thickness which is fixed on the rcc roof with 4 anchor fastners of 10mm.Each fastnerMade out of 48mm Outer Dai, 40 Nominal Bore Material for the light bar shall be of Mild Steel Pipe Dual Barrel Arrangement and an additional End Caps on the Pipe end Powder coated with Matt black Texture Fixing Through Suspenders as per site conditions.Suspender prices are included(Make: Leksa Lighting / Kenson Solace / Aultra Lighting / Canara )Rate as per Ref. BOQ Item No. 6.29 135 SITC of Power Distribution Electrical panel having a Individual MCB control for 6 outgoing circuits Made up of MS Sheet metal fabricated housing Black powder coated Ivery connectors for the internal terminations and external outgoing connecting points, Fibre / brass glands of suitable size fitted MCB control for outgoing circuits. Custom built as per specification and project requirement.(Make: Leksa Lighting / Kenson Solace / Aultra Lighting / Canara )Rate as per Ref. BOQ Item No. 6.30 136 SITC of High quality power junction box 4 way made up of MS Sheet metal fabricated housing. Snap fit fixing /15 (1.5mm ) Total Max Rating 10A, 250V A.C 20°C to +70°C Operating Temp Moldings: Nylon, Flammability Rating UL94V-0 Blackpowder coated, fibre glands of suitable size fitted with Powercon or IEC connector Box 10A. Clamp arrangement for fixing or Raul plug arrangement for wall / floorfixing.(Make: Leksa Lighting / Kenson Solace / Aultra Lighting / Canara )Rate as per Ref. BOQ Item No. 6.31 137 SITC of High quality power junction box 2 way made up of MS Sheet metal fabricated housing. Snap fit fixing /15 (1.5mm ), Total Max Rating 10A, 250V A.C 20°C to +70°C Operating Temp Moldings: Nylon, Flammability Rating UL94V-0 Black powder coated, fibre glands of suitable size fitted with Powercon or IEC connector Box 10A. Clamp arrangement for fixing or Raul plug arrangement for wall/floor fixing.(Make: Leksa Lighting / Kenson Solace / Aultra Lighting / Canara )Rate as per Ref. BOQ Item No. 6.32 138 SITC of High quality Dimming In junction box 1 way made up of MS Sheet metal fabricated housing High temperature resistant insulator material All metal housing offers best overall RF protection & electromagnetic shielding Black powder coated,fibre glands of suitable size fitted with 5 Pin DmX XLR Male socket Clamp arrangement for fixing or Raul plug arrangement for wall /floor fixing.(Make: Leksa Lighting / Kenson Solace / Aultra Lighting / Canara )Rate as per Ref. BOQ Item No. 6.33 139 SITC of DmX Loop Junction Box having 1 No. of DmX 5 Pin XLR Female Socket & 1 No. DmX XLR Male Socket fitted on to a sheet metal fabricated compact Junction box powder coated with matt black texture finish paint. High temperature resistantinsulator material All metal housing offers best overall RF protection & electromagnetic shielding. Clamp arrangement for fixing or Raul plug arrangement for wall /floor fixing.(Make: Leksa Lighting / Kenson Solace / Aultra Lighting / Canara )Rate as per Ref. BOQ Item No. 6.34 140 SITC of Internal Earthing System with copper bare conductors all along the cable trays, metal parts and Installation HardwaresRate as per Ref. BOQ Item No. 6.35 141 SITC of Black Powder coated cable trays made out of MS Sheet fabricated for a size of 40 x 75 x 40mm & 1.6 mm thickness undergone through 7 tank process with various chemical treatment to keep them rust free with perforation for heatdessipation provided with lid.Rate as per Ref. BOQ Item No. 6.36 142 SITC of DmX Male Female Connectors 5 Pin having rubber sheeth protection forCross connecting DmX wiring connections.(Make: Leksa Lighting / Kenson Solace / Aultra Lighting / Canara )Rate as per Ref. BOQ Item No. 6.37 143 SITC of DmX Male Termination Connector 5 Pin soldered with required capacity of resistor for signal deframing.(Make : Leksa Lighting / Kenson Solace / Aultra Lighting / Canara )Rate as per Ref. BOQ Item No. 6.38 144 SITC of DmX Controller 12 Faders to control atleast 12 channels with Master control fader ,12 Set Scene saving options Master Fader Enabled Controller , LCD display access,Eeasy access key pads 12 Physical Fader unit for direct access Incremental Channel Up & Down Buttons DmX 512 protocol.(Make: Leksa Lighting / Kenson Solace / Aultra Lighting / Canara )Rate as per Ref. BOQ Item No. 6.39 145 SITC of DmX Controller 12 Faders to control atleast 12 channels with Master control fader ,12 Set Scene saving options Master Fader Enabled Controller , LCD display access,Eeasy access key pads 12 Physical Fader unit for direct access Incremental Channel Up & Down Buttons DmX 512 protocol.(Make: Leksa Lighting / Kenson Solace / Aultra Lighting / Canara )Rate as per Ref. BOQ Item No. 6.40 146 SITC of FRLS Copper unarmoured Flexible cable IS694 having 3 Core each of 1.5 Sq mm size.Rate as per Ref. BOQ Item No. 6.41 147 SITC of 5 Core DmX Cable with Sheathed housing on the cable, well designed insulation, low noise suitable to transmit DmX signalRate as per Ref. BOQ Item No. 6.42 148 38 HP(As per DSR_VRF/VRV _2019_1.1) (Rate=16415X38) Make: Daikin/Mitsubishi Electric 149 36 HP(As per DSR_VRF/VRV _2019_1.1) (Rate=16415X36) Make: Daikin/Mitsubishi Electric 150 34 HP(As per DSR_VRF/VRV _2019_1.1) (Rate=16415X34) Make: Daikin/Mitsubishi Electric 151 12 HP(As per DSR_VRF/VRV _2019_1.1) (Rate=16415X12) Make: Daikin/Mitsubishi Electric 152 Indoor Unit Cassette TypeSupply, Installation, Testing & Commissioning of following minimum capacity 4-way flow VRF/VRF Cassette type indoor ceiling mounted unit equipped with synthetic washable media pre filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX Copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration isolator, cordess remote control etc., suitable for operation on single phase 230V + 10%, 50Hz AC supply, complete, as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS system or fire panel of the building. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature.Make: Daikin/Mitsubishi Electric3.2 TR 4 Way VRV/VRF Cassette Unit(As per DSR_VRF/VRV _2019_2.8) 153 2.0 TR 4 Way VRV/VRF Cassette Unit(As per DSR_VRF/VRV _2019_2.5) Make: Daikin/Mitsubishi Electric 154 0.8TR(As per DSR_VRF/VRV _2019_3.2)Make: Daikin/Mitsubishi Electric 155 1TR(As per DSR_VRF/VRV _2019_3.3) Make: Daikin/Mitsubishi Electric 156 1.3TR(As per DSR_VRF/VRV _2019_3.4) Make: Daikin/Mitsubishi Electric 157 1.65TR(As per DSR_VRF/VRV _2019_3.6) Make: Daikin/Mitsubishi Electric 158 2.0 TR(As per DSR_VRF/VRV _2019_3.7) Make: Daikin/Mitsubishi Electric 159 Indoor Unit Ductable TypeSupply, Installation, Testing & Commissioning of following minimum capacity and external static pressure VRF/VRV ceiling mounted ductable type indoor unit equipped with washable synthetic media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, corded remote control, outer cabinet, vibration isolators, drain pan, other necessary supports etc., suitable for operation on single phase AC supply 230 V + 10%, 50Hz, complete as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS system or fire panel of the building. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature.Mid Static Ductable Units (Minimum 45 Pascal External Static Pressure) Make: Daikin/Mitsubishi Electric4.0 TR(As per DSR_VRF/VRV _2019_4.16) 160 High Static Ductable Units (Minimum 110 Pascal External Static Pressure) Make: Daikin/Mitsubishi Electric5.5 TR(As per DSR_VRF/VRV _2019_4.17) 161 7.1 TR(As per DSR_VRF/VRV _2019_4.18) Make: Daikin/Mitsubishi Electric 162 8.0 TR(As per DSR_VRF/VRV _2019_4.19) Make: Daikin/Mitsubishi Electric 163 4.0 TR(As per DSR_VRF/VRV _2019_4.16) Make: Daikin/Mitsubishi Electric 164 11.0 TR (Market Rate) Make: Daikin/Mitsubishi Electric 165 15.0 TR (Market Rate) Make: Daikin/Mitsubishi Electric 166 17.0 TR (Market Rate) Make: Daikin/Mitsubishi Electric 167 Supply Installation, testing & commissioningof Y-joints for various size of Refrigerant pipe including insulation. (As per MR-1)(Rate=4123/1.18) 168 Centralized controllerSupply Installation, testing & commissioningofMainIntelligenttouch screen centralcontroller systemincluding all the accessoriessuitableto operate, monitor, on/off, temperature setting of all the indoor units individually complete as required and as specified. (As per MR-2) (Rate=80703/1.18) 169 Copper Refrigerant PipingSupply, Installation, Testing & Commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with with Class-O closed cell elastometric nitrile rubber insulation of specified thickness as given below for Suction and Liquid lines, exposed piping shall be protected with UV & water protective coating, all accessories as per specifications etc. as required:6.4 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation (As per DSR_VRF/VRV _2019_5.1) 170 9.5 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation(As per DSR_VRF/VRV _2019_5.2) 171 12.7 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation(As per DSR_VRF/VRV _2019_5.3) 172 15.86 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation(As per DSR_VRF/VRV _2019_5.4) 173 19 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19 mm thick insulation(As per DSR_VRF/VRV _2019_5.5) 174 22.2 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19 mm thick insulation(As per DSR_VRF/VRV _2019_5.6) 175 28.58 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19 mm thick insulation(As per DSR_VRF/VRV _2019_5.8) 176 34.9 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm with 19 mm thick insulation(As per DSR_VRF/VRV _2019_5.10) 177 41.27 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm with 19 mm thick insulation(As per DSR_VRF/VRV _2019_5.12) 178 Drain PipingSupplying & fixing of UPVC drain piping with all fitting such as bends, tees etc. necessary clamps, adequate support duly insulate with 9 mm nitrile rubber insulation complete as per technical specifications, requirement, standardard and drawings complete as required.50 mm dia(As per MR-3)(Rate=298/1.18) 179 40 mm dia(As per MR-3) (Rate=204/1.18) 180 32 mm dia(As per MR-3) (Rate=157/1.18) 181 25 mm dia (As per MR-3) (Rate=121/1.18) 182 Inline FansSupply, Installation, testing and commissioning circular direct driven / cabinet inline fans of G.I. construction complete with centrifugal fan with motor, accoustically lined, canvass connection at inlet and outlet complete with electric panel with MCB and relays, with 5 Rm cabling and earthing complete as per standards, requirement and drawings. 3300 cfm 20 mmwg S.P(As per MR-4)(Rate=45163/1.18)Make: Daikin/Mitsubishi Electric 183 800 cfm 15 mmwg S.P(As per MR-4) (Rate=23520/1.18) Make: Daikin/Mitsubishi Electric 184 550 cfm 15 mmwg S.P(As per MR-4) (Rate=17064/1.18) Make: Daikin/Mitsubishi Electric 185 500 cfm 15 mmwg S.P(As per MR-4) (Rate=17064/1.18) Make: Daikin/Mitsubishi Electric 186 450 cfm 15 mmwg S.P(As per MR-4) (Rate=15743/1.18) Make: Daikin/Mitsubishi Electric 187 400 cfm 15 mmwg S.P(As per MR-4)(Rate=15743/1.18) Make: Daikin/Mitsubishi Electric 188 350 cfm 15 mmwg S.P(As per MR-4)(Rate=15743/1.18) Make: Daikin/Mitsubishi Electric 189 300 cfm 15 mmwg S.P(As per MR-4) (Rate=14056/1.18) Make: Daikin/Mitsubishi Electric 190 250 cfm 15 mmwg S.P(As per MR-4) (Rate=13102/1.18) Make: Daikin/Mitsubishi Electric 191 200 cfm 15 mmwg S.P(As per MR-4) (Rate=13102/1.18) Make: Daikin/Mitsubishi Electric 192 150 cfm 15 mmwg S.P(As per MR-4) (Rate=12662/1.18) Make: Daikin/Mitsubishi Electric 193 100 cfm 15 mmwg S.P(As per MR-4) (Rate=12662/1.18) Make: Daikin/Mitsubishi Electric 194 Propeller Type FanSupply, installation, testing and commissoning of propeller type fan for exhaust air complete with in and out gravity louvers, 3 pin socket with 5RM cabling complete as per specifications, requirement, standard and drawings.Make: Daikin/Mitsubishi Electric200 mm dia,5 mmwg S.P. (As per MR-5)(Rate=13039/1.18) 195 Exposed Copper Pipe CoatingSupplying and fixing of UV/fire/water, thermal protective coating, with canvas/glass fibre cloth, coating on copper pipe insulation by wrapping canvas/glass fibre cloth dipped instarbond/polybond30-36completeasperspecificationsanddrawings.(Thepriceshouldbequotedconsideringminimum3coatsof30-36chemical). (AsperMR-6) (Rate=587/1.18) 196 Packaged Type AirwasherSupply, installation, testing and commissioning of floor mounted CELLULOSE FILL AIR-WASHER complete with double skin construction fabricated out of extruded aluminium sections with 0.8 mm thick pre-plasticised GI sheet on out side and 0.8 mm thick plane GI sheet inside with 25 mm thick insulation, 40 Kg / m3 density PUF insulation in between. The unit shall comprise of supply fan sections with DIDW backward curve fans (efficiency not less than 75%) suitable for static pressure as required,belt drivepackage with TEFC drive motor of efficiency class IE3suitable for 415 ± 10% V, 50Hz, 3 Phase AC supply, giving 95% adiabatic saturation efficiency at 500 FPM air velocity across pads, factory assembled and complete with 16 gauge GI casing for Air washer section, 18G SS-304 water tank, Cellulose fill, water distribution header, PVC piping, butterfly valves, for quick fill, isolation of tank, pumps and brass strainers, Y strainers, fire rated flexible duct connections & aluminium volume control damper at blower discharge and necessary fittings, belt drive package, necessary vibration isolation arrangement etc. complete as per specification and of following capacities. The fan and motor shall be mounted on aluminium extruded section.The unit shall also include provision of GSS partitions duly reinforced at intake side of air washer and GSS louvers with bird-screen synthetic washable filters and four bend PVC drift eliminators and horizontal monoblock pumps of suitable rating, factory mounted on mild steel channel base with electric motor for circulation of water. Pumps shall be aligned and suitable for 415±10% volts, 50 cycles 3 phase power supply. One No. 3 phase isolator switch in weather proof enclosure shall be provided near motor complete as required confirming to specification. Make: Daikin/Mitsubishi Electric3,000 CFM, 50 mmwg Static Pressure (As per MR-7)(Rate=205427/1.18) 197 Exhaust ScrubberSupply, installation, testing & commissioning of double skin exhaust scrubber of 0.6 mm inner and outer skin construction fabricated from precoated sheet blower housing with DIDW backward curved centrifugal blower with fan motorand belt drive arrangement with totally enclosed fan cooled class F insulation, with IP 55 protection, TEFC high efficiency motor type IE-3 suitable for 415+-10% volts, 50 HZ, 3 Phase A.C. supply, all accessories like common base frame, fan, motor pulley, belts, fire proof canvass connection, vibration isolator, prefilters, wet scrubber section, spray, nozzels, filters, M.S. frame for supports etc.complete as per specifications, requirement, standardard and drawings.Make: Daikin/Mitsubishi Electric4,000 CFM, 65 mmwg Static Pressure (As per MR-8) (Rate=220100/1.18) 198 DuctingSupply, installation, balancing and commissioning of factory fabricatedGSS sheet metal rectangular ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.G.I. Sheet Metal Ducting (Rectangular)Thickness 0.63 mm sheet (As per DSR_E&M _2022_16.12.1.1)(Rate=1080/1.12) 199 Thickness 0.80 mm sheet (As per DSR_E&M _2022_16.12.1.2)(Rate=1263/1.12) 200 Thickness 1.0 mm sheet (As per DSR_E&M _2022_16.12.1.3)(Rate=1381/1.12) 201 Thickness 1.25 mm sheet (As per DSR_E&M _2022_16.12.1.4)(Rate=1836/1.12) 202 Grilles / DiffuserSupply, installation, testing and commissioning of Aluminium extruted powder coated supplyand returnairgrilles/ diffusers as per specifications and drawings (Approval of colour shall be taken from Architects/Consultants).Supplying&fixingofpowdercoatedextrudedaluminiumSupplyAirGrillswithaluminiumvolumecontroldampersasperspecifications.(AsperDSR_E&M_2022_16.15)(Rate=9105/1.12) 203 Supplying&fixingofpowdercoatedextrudedaluminiumReturnAirGrillswithlouversbutwithoutvolumecontroldamperscompleteasrequired.(AsperDSR_E&M_2022_16.16)(Rate=5910/1.12) 204 Supply, fixing, testing & commissioning of Return air diffussers of powder coated aluminium without volume control dampers with anti smudge ring & removable core.(As perDSR_E&M _2022_16.18)(Rate=8121/1.12) 205 LouversSupply and fixing of Fresh / Exhaust air Aluminium extruded with bird screen, damper adjustable louvers as per specifications and drawings.(As per MR-9)(Rate=12986/1.18) 206 Volume Control DamperSupply, installation,testing andcommissioning ofGIvolumecontrol duct damper completewith neoprenerubber gaskets, nuts, bolts, screws linkages,flanges etc, as per specifications. (As per DSR_E&M _2022_16.13)(Rate=7046/1.12) 207 Flexible DuctSupply of 25 mm glass wool insulated double lamination of metalize polister film parmantely bounded to a coated spring wire, helix and resistant construction of tear and pincture branch and collor where ever suitable of following sizes. Connected at both ends with necessary jublie clamps150 MM Dia(As per MR-10)(Rate=404/1.18) 208 IsolatorSupplying & installation of weather proof isolator with suitable rating near each outdoor unit and complete as required. 63 Amps(As per MR-11)(Rate=5136/1.18) 209 40 Amps(As per MR-11)(Rate=5136/1.18) 210 Control & Transmission WiringSupplying & fixing control cum transmission wiring of copper in heavy duty conduits PVC conduits between indoorand out door unit. (As per MR-12)(Rate=113/1.18) 211 Sub Panel For KitchenSupply, installation,testing & commissioning of sub panel board cubical compartmentalised, weather proof Floor/ Wall mounted made of 2.0 mm thick steel sheet duly painted completewithvoltmeter,ammeter,indicatinglightsforselectorswitch,incoming/outgoingfeeders,NO/NC contactors,CTScontactorscompleteasperspecificationsand requirement1 No. 32 Amps TPN incoming MCB1 set 40 Amps TPN Aluminium conductor bus bar duly sleeved.2 Nos. 25 Amps MCB outgoing along with 2 Nos. DOL starter for Scrubber Motor (5.5 kw) (1 No Spare). 2 Nos. 16 Amps MCB outgoing along with 2 Nos. DOL starter for Airwasher Motor (3.7 kw) (1 No Spare).3 Nos. 6 Amps SPN MCB outgoing for Airwsher & Scrubber Pump.(0.37 / 0.55 kw) (1 No. Spare).(As per MR-13)(Rate=124723/1.18) 212 Power CablingSupply & fixing of PVC sheathed Aluminium / Copper cables for various equipments through walls/ceiling with appropriate clamps & fixing arrangement as per specifications and drawings.3C - 4 sqmm (Aluminium) for Airwasher & Scrubber(As per MR-14)(Rate=126/1.18) 213 3C - 2.5 sqmm (Aluminium) for Airwasher & Scrubber pump(As per MR-14)(Rate=117/1.18) 214 4C - 16 sqmm (Copper) (As per MR-14)(Rate=1102/1.18) 215 4C - 10 sqmm (Copper) (As per MR-14)(Rate=753/1.18) 216 Cable TraySupplying and installation of following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc. as required.150 mm width X 50 mm depth X 1.6 mm thickness(As per DSR_E&M _2022_4.1.2)(Rate=604/1.12) 217 300 mm width X 50 mm depth X 1.6 mm thickness(As per DSR_E&M _2022_4.1.4)(Rate=777/1.12) 218 450 mm width X 50 mm depth X 1.6 mm thickness(As per DSR_E&M _2022_4.1.6)(Rate=1137/1.12) 219 EarthingProviding and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. (As per DSR_E&M _2022_5.15)(Rate=244/1.12) 220 Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.(As per DSR_E&M _2022_5.16)(Rate=70/1.12) 221 Ductable Split UnitSupplying,installation,testing & commissioning of ductable type split unit air-conditioners with evaporator with coil, fan and fan motor, aircooled condenser with hermatically sealed scroll compressor, condenser coil, propeller fans controls, mounting stand for ODU, control panel, corded remote, canvass connection as per standards, requirement and drawings.Make: Daikin/Mitsubishi Electric3.0 Tons(1 Working & 1 Standby) for Server Room(As per MR-15)(Rate=88040/1.18) 222 Refrigerant Piping (For Split)Supplying & installation copper soft/hard refrigerant piping along (Circuit length) with control cabling and earthing should be insulated with 9 mm thick pipe section of nitrile rubber complete in all respect.3.0 Tons Ductable Split Unit(As per MR-16)(Rate=1981/1.18)
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 3
Uttar Pradesh View Result →
21.
Housing Urban and Rular Development #9443236 Technical Bid
Tender For Construction Of Chakrateertha Kund Complex And Other Truism Development Work At Naimisharanaya, District- Sitapur (U.P.), 1 Construction of Chakrateertha Kund Complex and Other Truism Development work at Naimisharanaya, District- Sitapur (U.P.) 2 Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge. All kinds of soil 3 Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials. All kinds of soil l (1.5m to 3.0m) 4 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. 5 Supplying chemical emulsion in sealed containers including delivery as specified. Chlorpyriphos/ Lindane emulsifiable concentrate of 20% 6 Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: With Chlorpyriphos/Lindane E.C. 20% with 1% concentration 7 Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. 8 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) 9 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. 10 Centring and shuttering including strutting,propping etc. and removal of form for 11 Foundations, footings, bases of columns etc. for mass concrete. 12 Suspended floors, roots, landings, balcnies and access platform. 13 Lintels, beams, plinth bams, griders, bressumers and cantilevers. 14 Columns,Pillars, Piers, Abutments, Posts and Struts 15 Stairs,(excluding landings) except spiral-staircaces. 16 Weather shade,Chajjas, corbels etc. including edges 17 Extra for additional height in centring, shuttering where ever required with adequate bracing, propping etc. including cost of deshutering and de centring at all levels over a height of 3.5 m ,for every additional height of 1 metre or part thereof (Plan area to be measured) Suspended floors, roots, laning, beams and balconies (Plan area to be measured) 18 Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete upto plinth & above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. 19 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. Concrete of M25 grade with minimum cement contant of 330 kg/cum All works upto plinth level 20 Concrete of M25 grade with minimum cement content of 330 kg /cum 21 Providing and fixing of expansion joint system related with floor location as per drawings and direction of Engineer-In-Charge. The joints system will be of extruded aluminum base members, self aligning / self centering arrangement and support plates etc. as per ASTM B221-02. The system shall be such that it provides floor to floor /floor to wall expansion control system for various vertical localtion in load application areas that accommodates multi directional seismic movement without stress to it’s components. System shall consist of metal profiles with an universal aluminum base member designed to accommodate various project conditions and finish floor treatments. The cover plate shall be designed of width and thickness required to satisfy projects movement and loading requirements and secured to base members by utilizing manufacturer’s pre-engineered self- centering arrangement that freely rotates / moves in all directions. The Self - centering arrangement shall exhibit circular sphere ends that lock and slide inside the corresponding aluminum extrusion cavity to allow freedom of movement and flexure in all directions including vertical displacement. Provision of Moisture Barrier Membrane in the Joint System to have watertight joint is mandatory requirement all as per the manufactures design and as approved by Engineer -in-Charge. (Material shall conform to ASTM 6063). Floor Joint of 100 mm gap 22 Providing and fixing of expansion joint system related with wall joint (internal/external) location as per drawings and direction of Engineer-In- Charge. The joints shall be of extruded aluminum base members, self aligning / centering arrangement and support plates as per ASTM B221- 02. The material shall be such that it provides an Expansion Joints System suitable for vertical wall to wall/ wall to corner application, both new and existing construction in office Buildings & complexes with no slipping down tendency amongst the components of the Joint System. The Joint System shall utilize light weight aluminum profiles exhibiting minimal exposed aluminum surfaces mechanically snap locking the multicellular to facilitate movement. (Material shall conform to ASTM 6063). Wall Joint of 100 mm gap 23 Providing and fixing of expansion joint system of approved make and manufactures for various roof locations as per approved drawings and direction of Engineer-In-Charge. The joints shall be of extruded aluminum base members with, self aligning and self centering arragement support plates as per ASTM B221-02. The system shall be such that it provides watertight roof to roof/roof to corner joint cover expansion control system that is capable of accommodating multidirectional seismic movement without stress to its components. System shall consist of metal profile that incorporates an universal aluminum base member designed to accommodate various project conditions and roof treatments. The cover plate shall be designed of width and thickness required to satisfy movement and loading requirements and secured to base members by utilizing manufacturer’s pre-engineered self-centering arrangement that freely rotates / moves in all directions. The Self centering arrangement shall exhibit circular sphere ends that lock and slide inside the corresponding aluminum extrusion cavity to allow freedom of movement and flexure in all directions including vertical displacement. The Joint System shall resists damage or deterioration from the impact of falling ice, exposure to UV, airborne contaminants and occasional foot traffic from maintenance personnel. Provision of Moisture Barrier Membrane in the Joint System to have water tight joint is mandatory requirement. (Material shall conform to ASTM 6063). Roof Joint of 100 mm gap 24 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand) 25 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand) 26 Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. Cement mortar 1:4 (1 cement :4 coarse sand) 27 Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry. 28 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite stone slab of colour black, Cherry/Ruby red 29 Area of slab upto 0.50 sqm 30 Area of Slab over 0.50sqm 31 Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. Granite work. 32 Extra for fixing marble /granite stone, over and above corresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive, including cleaning etc. complete. 33 Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. 34 Providing and fixing 12 mm toughened glass partition with neccessary fittings and Applying clear silicon on joints complete in all respect. 35 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws 36 Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edge 37 Extra for providing vision panel not exceeding 0.1 sqm in all type of flush doors (cost of glass excluded) (overall area of door shutter to be measured): Rectangular or square. 38 Float glass panes 5.0 mm thick glass panes (weight not less than 12.50 kg/sqm). 39 Providing & Fixing decorative high pressure laminated sheet of plain /wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality. 1.0 mm thick 40 Providing and fixing Single Glazing 6mm thick ET 125 series (Saint Gobain)toughened glass complete in all respects as per direction of the Engineer-in-charge. (Required properties Solar factor = 0.45, U-Value = (W/sq.m-K) 5.7W /M2K, Visible light transmittance = 0.30) 41 Providing and fixing approved brand and manufacture SS 304 Lever Handle D-type fixed with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 42 Providing and fixing approved brand and manufacture SS 304 grade SS 304 grade Mortice lock with key cylinder fixed fixed with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 43 Providing and fixing approved brand and manufacture SS 304 grade Tower bolt 300 mm long with 10mm dia fixed with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 44 Providing and fixing approved brand and manufacture SS 304 grade Tower bolt 150mm long with 10mm dia fixed with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 45 Providing and fixing approved brand and manufacture SS 304 grade wall mounted door buffer fixed with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 46 Providing and fixing approved brand and manufacture SS 304 grade Door Stopper - door mounted hanging type fixed with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 47 Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete.. 48 Providing and fixing approved brand and manufacture SS 304 grade Top & Bottom Patch fixed with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 49 Providing and fixing approved brand and manufacture SS 304 grade H type 900mm Pull Handle with 32mm dia fixed with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 50 Providing and fixing approved brand and manufacture SS 304 grade Center Patch Lock wih Cylinder complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 51 Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge.With stainless steel cover plate minimum 1.25 mm thickness 52 Providing and fixing 12 mm thick frameless toughened glass partitions of approved brand and manufacturer, including providing and fixing partitions at top & bottom with aluminum channel etc. all complete as per direction of Engineer-in-charge 53 Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. M.S. tube 54 Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works 55 Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete Fastener with threaded dia 10 mm 56 Stone work (machine cut edges) for wall lining etc. (veneer work) upto 10 metre height, backingfilled with a grout of average 12 mm thick cement mortar 1:3 (1 cement : 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade : (To be secured to the backing and the sides by means of cramps and pins which shall be paid for separately) : White sand stone - exposed face fine dressed with rough backing 30 mm thick 57 Providing and fixing stainless steel cramps of required size and shape for anchoring stone wall lining to the backing or securing adjacent stones in stone wall lining in cement mortar 1:2 (1 cement : 2 coarse sand), including making the necessary chases in stone and holes in walls wherever required. 58 Providing and fixing copper pins 7.5 cm long 6 mm diameter for securing adjacent stones in stone wall lining in cement mortar 1:2 (1 cement : 2 coarse sand), including making the necessary chases 59 Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. 40 mm thick with 20 mm nominal size stone aggregate 60 Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. Glazed Vitrified tiles Matt/Antiskid finish of size Size of Tile 600 x 600 mm 61 Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge. Size of Tile 600x600 mm 62 Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/sqm including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600x600 mm 63 Providing and laying Vitrified tiles in floor with different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately) Size of Tile 600x600 mm 64 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 65 Providing and laying 18 mm thick leather finish steel grey granite stone flooring in required design and patterns, in linear as well as curvilinear portions in building flooring, footpath etc. all complete as per the architectural drawings with over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. 66 Providing and fixing machine cut, mirror/ eggshell 18mm thick leather finish steel grey granite stone work for wall lining (veneer work) including dado, skirting, risers of steps etc., in required design and pattern wherever required, stones of different finished surface texture, on 12 mm (average) thick cement mortar 1:3 (1 cement : 3 coarse sand) laid and jointed with cement slurry @ 3.3 kg/sqm including pointing with white cement slurry admixed with pigment of matching shade, including rubbing, curing, polishing etc. all complete as per Architectural drawings, and as directed by the Engineer-in-Charge. 67 Applying breathable, non-reactive,antifungal, and water repellant Silane/Siloxane chemical as approved by Archaeological Survey of India/ Engineer-in-charge, of approved brand and manufacture, diluted with solvent mineral Turpentine oil in the ratio of 1:12 (One part of approved chemical :12 Part of Turpentine oil), on the existing sand stone masonry surface with two or more coats to give uniform application of chemical on the surface, all complete as per direction of Engineer-In-charge (The rate is inclusive of all materials & labours involved except scaffolding). 68 Supply, fabricating, transporting, hoisting and fixing in position good quality durable Mirzapur sand stone/ any other type of sand stone in various elements for all level all height.Stone shall be free from cracks, lines, stains, white spots of efflorescence and even in shade for each elements. The stone shall be fine grained and reddish or buff-colored (locally available). The work shall be carried out as per attached drawings with differant process ofi.e carving (manual/ by machine), ornamental work, traditional work, figure work (any type, any size), CNC cutting, moulding. The drawings provided are vary preliminary and amount of carving will be more then what is shown on the drawings. The carving and molding work shall be of very good quality. The stones to be fixed in line, level and plumb in all respect with the use of brass clamps, pins, dowels, cement slurry with matching pigment and Epoxy of Akemi Germany, Ardex Endura, MYK laticrete or approved make as required and as approved by the Architects. 69 40 mm thick rubbed stone flooring over 20 mm (average) thick base of cement mortar 1:5 (1 cement : 5 coarse sand) with joints 3 mm thick, side buttered with cement mortar 1:2 (1 cement : 2 stone dust) admixed with pigment to match the shade of stone and pointing with same mortar. White sand stone 70 Providing and laying Laminate wooden flooring (Grade AC4, 8 mm thick Ambience Premium-AC4 ), having a good backing layer made up of plastic laminate or melamine as specified by the manufacturer and approved by Engineer-incharge. 71 Providing and fixing 40mm thick cladding comprising of Wooden framework using 25mx50mm sections at a maximum spacing of 600mm in any one direction (including adding members as required) covered with12mm thick BWP ply layered with 4mm thk. veneer on one sidepasted and pressed with adhesive to give a uniform and smooth finish, including4mm thk. S.S. strip framework on all sides of veneer panels with wooden member surround, top moldings / margins, melamine polish etc. to finish the thickness, as shown complete in drawing. All members / ply etc. shall be treated with anti-termite solution as per norms. No extra shall be paid for making of openings, door / window frames and for making provisions for electric conduits. etc. all complete as per direction of Engineer-in-charge. 72 Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished Granite stone slab of colour Black, Cherry/Ruby Red or equivalent 73 Providing and fixing Granite stone gang saw cut (polished and machine cut) of thickness 18mm for wall lining, backing filled with a grout of average 12mm thick in cement mortar 1:3 (1 cement : 3 coarse sand), including pointing with white cement mortar with an admixture of pigment to match the granite shadeetc. all complete as per Architectural drawings, and as directed by the Engineer-in-Charge. 74 12mm cement plaster of mix : 1:6 (1 cement : 6 fine sand) 75 15 mm cement plaster on the rough side of single or half brick wall of mix : 1:6 (1 cement : 6 fine sand) 76 6 mm cement plaster to ceiling of mix : 1:3(1 cement: 3 coarse sand) 77 18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster 1:6 (1 cement : 6 fine sand). 78 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 79 Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour : New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre 80 Providing & fixing galvanized low carbon wire, anealed wire Chicken mesh formed by twisting two adjacent wires at least four times, forming a hexagonal shaped strong honeycomb mesh structure on joints of RCC & Brick work before plastering, of required gauge (not less than 21 gauge)and size with nails etc. complete as specified in drawing and as per the Direction of Engineer-in-charge. 81 Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. Two or more coats on new work 82 Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre 83 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : 84 Two or more coats on new work 85 Melamine polishing on wood work (one or more coat) 86 Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes, finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer’s specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : 87 12.5 mm thick tapered edge Glass Reinforced Gypsum (GRG) board conforming to IS: 2095- (Part 3):1996 (Boards with BIS certification marks) 88 Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm 89 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : For fixed portion Powder coated aluminum (minimum thickness of powder coating 50 micron) 90 For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Powder coated aluminum (minimum thickness of powder coating 50 micron) 91 Filling the gap in between aluminium/ stone/ wood frame and adjacent RCC/Brick/ Stone/ wood/ Ceramic/ Gypsum work by providing weather/structural non sag elastomeric PU sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete, complying to ASTM C920, DIN 18540- F & ISO 11600 Upto 10 mm depth and 10 mm width 92 Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge (Door handle, lock and stopper etc.to be paid separately). 93 Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. (b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. (c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge. (d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. (e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“All above operations to be done in order and as directed and specified by the Engineer-in-Charge : With average thickness of 120 mm and minimum thickness at khurra as 65 mm 94 Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. 95 Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : In 75x75 mm deep chase 96 Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. without disturbing the other structural elements. Nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix) 97 Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge. without disturbing the other structural elements such as column, beams & slab. 98 Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.In cement mortar 99 Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 50 metres lead. 100 Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. For thickness of tiles 10 mm to 25 mm 101 Dismantling stone slab flooring laid in cement mortar including stacking of serviceable material and disposal of unserviceable material within 50 metres lead. 102 Demolishing brick tile covering in terracing including stacking of serviceable material and disposal of unserviceable material within 50 metres lead. 103 Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. 104 Pumping out water caused by springs, tidal or river seepage, broken water mains or drains and the like. 105 Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared. 106 Supplying and stacking at site dump manure screening by 4.75 mm sievefrom approved source, including carriage upto 5 km complete (manure measured in stacks will be reduced by 8% for payment) : 107 Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing includingremoval of rubbish and surplus earth, if any, with all leads and lifts (cost ofmanure, sludge or extra good earth if needed to be paid for separately) Holes 60 cm dia, and 60 cm deep 108 Mixing earth and sludge or manure in the required proportion specified or directed by the Officer-in-charge 109 Providing and laying Neelgiri/Mexican grass turf with earth 50mm to 60mm thickness of existing ground prepared with proper level and ramming with tools wooden (Dhurmos) and than rolling the surface with light roller make the surface smoothen and light waterning with sprinkler and maintenance for 30 days or more till the grass establish properly, as per direction of officer-in-charge. 110 Providing and stacking of Plumeria alba of height 165-180 cm. with 3-4 branches and thick stem in big size HDPE bags as per direction of the officer-in-charge. 111 Providing and stacking of Hibiscus rosasinensis of height 90-105 cm., bushy in big size HDPEbag as per direction of the officer-in-charge. 112 Providing and displaying of Dracaena margineta plant, having ht. 30 cm to 45 cm with colorful leaves, fresh and healthy in 20 cm size of Earthen pot/Plastic pot & as per direction of the officer-in-charge. 113 Complete maintenance of the entire garden features having as per yard stick in the garden area i.e lawn trees,shrubs, hedge, flower beds,foliages,creepers etc including hoeing, weeding pruning replacement of plants, gap filling, watering,mowing of lawn,grass cutting by lawn mover and brush cutter, removal of garden waste, applying insecting sites,pesticide and fertilizers (whenever required) top dressing of lawn with good earth and menure and maintenance of other garden related works as directed by office in charge. (cost of good earth,menure, fertilizers, insecticide , pesticide,lawn mover and brush cutter with fuel will be provided by the department and other T/P material/articles shall be provided by the contractor. Open spaces (1Mali for 3.00 Acre). 114 Providing and fixing watercloset squatting pan (Indian type WC pan) with 100mm sand cast Iron P or S Trap, including wall hung cistern & installation kit with duel flush fitting (2.0/4.0 lts. per flushing), conforming to IS 7231, with all fittings & fixtures complete including cutting and making good the walls and floors wherever required.( MAKE-1 : JAQUAR, MODEL NO. INDIAN WC : ECS-WHT-453LE & CISTERN : WHC-WHT-184BTTG OREQUIVALENT.) White vitreous china Orissa pattern WC pan of size 415 x 515 x 255mm . 115 Providing and fixing white vitreouschina extended wall mountedwater closet of size 350 X 545 X 380mm of approved shape including providing and fixingof concealed cistern with duel flush fitting (2.0/4.0 lts. per flushing), including sheet cover, and cistern fittings, nut bolt gasket,chair etc complete. ( MAKE-1: JAQUAR, MODEL NO. WALL MOUNTED WC : FLS-WHT-5953 & CISTERN & FACE PLATE :JCS-WHT-2400SG & JCP-CHR-152415 OREQUIVALENT.) 116 Providing and fixing white vitreous china flat back half stall urinal of size 370 x 315 x 620mm with urinal valve auto closing system (0.75 lts. per flushing) with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required :. ( MAKE-1: JAQUAR, MODEL NO. URINAL : URS-WHT-132530 & URINAL VALVE AUTO CLOSING :PRS-CHR-077G OREQUIVALENT.) 117 Providing and fixing white vitreous china Oval shaped wash basin for top/under counter mounting with15 mm C.P. brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls whereever required. ( MAKE-1: JAQUAR, MODEL NO. WASH BASIN : FSS-WHT-29601 & BASIN MIXER :FLR-CHR-5001BG & WASTE COUPLING : ALD-CHR-705 OREQUIVALENT.) White Vitreous China Oval shaped Wash basin size 545 x 545 x 180mm with 15mm CP Brass single hole basin mixer with flow rate 2.5 litre per minute at 3 bar . 118 Providing and fixing Stainless Steel AISI 304 (18/8) kitchen sink as per IS: 13983 with C.I. brackets and stainless steel plug 40 mm, including painting offittings and brackets,cuttingandmakinggoodthe walls wherever requiredKitchen sink with drain board 119 510x1040 mm bowl depth 250 mm 120 Providing and fixing hand shower (Health faucet)with 1.2mtr long with 8mm dia Easy Flex Tube with wall hook and flow restrictor withflow rate 6 litre per minute at 3 bar in chrome finish and wall hook. ( MAKE-1: JAQUAR, MODEL NO. HEALTH FAUCET : ALD-CHR-573GA OREQUIVALENT.) 121 Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. ( MAKE-1: JAQUAR, MODEL NO. BOTTLE TRAP : ALD-CHR-769L300X190 OREQUIVALENT.) 122 Providing and fixing Differecially abled toilets including Wash basin, Water closet,Cistern, grab bars & hand rails etc. The rate include cost of all material & labour involved in the item complete and all as per direction of engineer incharge. For physically handicap person consisting of; 123 Wall mounted WC Pan-01 no. withbuilt in Jet of Cera CAT no.S1046105 124 Concealed Cistern Cistern-01 no.of Cera CAT no. B1110108 & Knob B1120118 125 Soft Close Seat Cover -01 no of Cera CAT no.B1520106 126 Wall hung Wash Basin -01 no of Cera CAT no.S2040147 127 Spatula Single leverCera CAT no F9030451 128 Wall mounted Grab bar 600 mm long - 2 nos of Cera CAT no.B2210106 129 Wall mounted Hinged hand rail 750 x 100-01 no Cera CAT no B2210108 130 Bottle Trap Cera CAT no F8060403 131 Waste Coupling Cera CAT no F8050101 132 Stainless soap dish Cera CAT no F5007106 133 Tissue paper holder Cera CAT no F5007110 134 Providing & fixing PVC waste pipe for sink including PVC waste fitting Complete40mm Dia 135 Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. 136 Providing & fixing toilet paper holder C.P. brass 137 Providing and fixingof fully automatic NO TOUCH durable & shock proof hand drier of approved make & manufacture suitable to operate on 220 volts, single phase 50 hz, A.C. power supply, 1500 Wattand directly plugged to power point complete in ABS plastic body having drying time 20-30 seconds complete as per direction of Engineer in Charge. The rate include cost of all material & labour involved in the item complete and all as per direction of engineer incharge. 138 Providing, Fixing of CP brass Towel Rack 600mm long without hanger with 3 hooks and CP brass screws complete as required. 139 Providing & fixing glass urinal partition of Height: 900mm,Width: 450mm &Frosted Safety Glass: 8 mm with fixed with expandable anchor fasteners with C.P. brass bolts and washers, embedded in wall with anchor and set in cement concrete complete including cutting and making good the walls wherever required. 140 Providing and fixing soil waste and vent pipesHubless centrifugally cast (spun) iron pipes epoxy coated inside & outside IS:15905 75 mm dia. 141 Providing and fixing M.S. holder-bat clamps of approved design to sand cast iron/ centrifugally cast iron(spun) pipes embedded in and including cement concrete blocks 10x 10 x 10 cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) including cost of cutting holes and making good the walls, etc. 142 For 100mm dia pipe 143 Providing and fixing bend of required degree with access door insertion rubber washer 3mm thick, bolts and nuts complete 144 100 mm dia 145 Hubless centrifugally cast (spun) iron epoxy coated inside & outside as per IS:15905 146 75 mm dia 147 Providing and fixing plain bend of required degree: 148 100 mm dia 149 Hubless centrifugally cast (spun) iron epoxy coated inside & outside as per IS:15905 150 75 mm dia 151 100 mm 152 SS 304 grade coupling with EPDM rubber gasket 153 75 mm 154 Providing and fixing M.S. stays and clamps for sand cast iron/centrifugally cast (spun) iron pipe of diameter: 155 100mm 156 Providing and fixing trap of self cleansing design with sand cast iron screwed down or hinged grating with or without vent, arm complete, including cost of cutting and making good the walls and floors. 100mm inlet and 100mm outlet Hubless centrifugally cast (spun) iron epoxy coated inside & outside as per IS:15905 157 Providing and fixing M.S. holder bat clamp of approved design to sand cast iron/ cast iron (spun) pipes comprising of M.S. flat brackets made of 50x5 mm flat of specified shape, projecting 75 mm outside the wall surface and fixed on wall with 4nos, 6mm dia expansion hold fasteners, including drilling necessary holes in brick wall/ CC/RCC surface and the cost of bolts etc. The pipes shall be fixed to the already fixed brackets with the help of 30 mm x1.6 mm galvanised M.S. flats of specified shape and of total length 420 mm and shall be fixed with M.S. nuts, bolts, & washers of size 25x6 mm, one bolts on each side of the pipe. 158 Total bracket length 580 mm of approved shape and design (for single 100 mm dia pipe) 159 Total bracket length 810 mm of approved shape and design (for two 100 mm dia pipes) 160 Providing & fixing Nickel Chromium Platedliquid soap container/ dispenser with metallic bottle of approved brand & make112 mm distance from wall of standard shape with bracket (Nickel chromium plating should pass Salt Spray Test for 200 hours) of the same materials with snap fittings of approved quality and colour, complete as per direction of Engineer in Charge. ( MAKE-1 : JAQUAR, MODEL NO. - ACN-CHR-1137N OR EQUIVALENT. 161 Providing, Fixing of CP brass Towel Ring with CP brass wall brackets and providing & fixing CP brass screws complete as required. ( MAKE-1: JAQUAR, MODEL NO. TOWEL RING : ACN-CHR-1121N OREQUIVALENT.) 162 Providing & fixing soap dish holder of approved design.( MAKE-1: JAQUAR, MODEL NO. SOAP DISH : ACN-CHR-1131N OREQUIVALENT.) 163 Providing and fixing white vitreous china Oval shaped wash basin for top/under counter mounting with 15 mm C.P. brass pillar tap of auto closing type of approved quality and make with, including painting of fittings and brackets, cutting and making good the walls whereever required. ( MAKE-1: JAQUAR, MODEL NO. WASH BASIN : FSS-WHT-29601 & PILLAR TAP :PRS-031G & WASTE COUPLING : ALD-CHR-705 OREQUIVALENT.) 164 White Vitreous China Oval shaped Wash basin size 545 x 545 x 180mm with 15 mm C.P. brass pillar tap auto closing type of approved make with flow rate 2.5 litre per minute at 3 bar . 165 Providing and fixing CP brass single lever low flowwall mounted Sink mixer with 15 mm CP brass single lever swivel spout with waste complete with flow rate 2.5 litre per minute at 3 bar including cutting and making good the walls where required. ( MAKE-1: JAQUAR, MODEL NO. SINK MIXER : FLR-CHR-5163GD OREQUIVALENT.) 166 Providing , Fixing of CP Brass Shower Mixer with provision of overhead shower with 115mm long bend pipe, in built spout, spout/shower selector with flow rate 3.8 litre per minute at 3 bar, wall flange complete with all accessories as required and making good the walls wherever required. ( MAKE-1: JAQUAR, MODEL NO. SHOWER MIXER : FLR-CHR-5273UPRGD OREQUIVALENT.) 167 Providing,Fixing wall mounted Double Coat hookon door complete. ( MAKE-1: JAQUAR, MODEL NO. COAT HOOK : AKP-CHR-35761P OREQUIVALENT.) 168 Providing & fixing wall mounted 300mm Long SS Grab Bar including cutting & making good the walls. ( MAKE-1: JAQUAR, MODEL NO. GRAB BAR : AKP-CHR-35701PS OREQUIVALENT.) 169 Providingand fixing CP brass 2 Way Bib cock with wall flange with flow restrictor with flow rate 2.5 litre per minute at 3 bar. ( MAKE-1: JAQUAR, MODEL NO. 2 WAY BIB COCK : FLR-CHR-5041NG OREQUIVALENT.) 170 Providibng and fixing straight type Macfit single body push fit type WC pan connector with factory supplied spring loaded seal guard of McAlpine, UK with integral single mould sealing fins made of flexible EVA body, including bush/adaptor for use with C.I. Pipe as supplied with the pan connector. 171 Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing complete as required. (MAKE-ModiGuard Sparkle Mirror ) 172 Providing & fixing 100mm x 50mm G.I. waste with reducing elbow & nipple cutting chases, the floor / slab, repairs complete as required and connection to GI / CI waste pipe. 173 Providing and fixing cast brass Floor cleanout plug with suitable insert keys for opening in brass cap, male threaded joint/reducer with G.I. socket caulked to Pipe/fittings of CI pipe including cost of lead joints etc. complete in all respect.100 mm dia 174 Providing and fixing GI inlet fitting with maximum 3 inlets 32,40 or 50 mm size fabricated from 100 dia GI pipes andsockets,fixed to C.I. trap with Drip Seal joint and set in cement concrete as per standard drawing complete as directed by Engineer-incharge. 175 Providing and fixing SS Grating of 125 mm dia of approved quality and colour complete as per direction of engineer in charge.Circular Type 125 mm nominal dia with 25 mm waste hole 176 Providing, Installing & fixing storage type water heater of approved shade with copper container, glasswool insulation,stove enamelled M.S jacket, thermostatically controlled inner heater with pilot neon lamps, 15mm inlet stop cock valve, on inlet connection, 15mm dia C.P flexible connection pipe in inlet & outlet suitable for working pressure of 8 kg/sqcm complete as required. 177 Capacity 15 litres size 448X448X345mm ( MAKE-1: JAQUAR, MODEL NO. GEYSER : ELENA OREQUIVALENT.) 178 Capacity 35 litres size 875X400mm ( MAKE-1: JAQUAR, MODEL NO. GEYSER : VERSA HORIZONTAL MANUAL OREQUIVALENT.) 179 Supplying fitting and fixing Ajoy Flowguard CPVC (Chlorinated Polyvinyl Chloride) pipes having thermal stability for hot and cold water supply including all CPVC Plain and bruss threaded fitting including clamps at 1.00 m spacing including joining of pipes and fitting with one step CPVC solvent cement and testing of joints complete at all levels as directed and spcified (In Terrace & Shaft- Hot Water Supply) 180 (Note: Ball Valve and union will be charged extra and does not comes under Accessories) In internal Wall - Exposed on Wall 181 20 mm OD 182 25 mm OD 183 32mm OD 184 40 mm OD 185 Providing and fixing GI pipes(IS:1239 Heavy Class) complete with GI fittings and clamps, i/c cutting and making good the walls etc.(In Terrace & Shaft- Cold & Flushing Water Supply) 186 Internal work - Exposed on Wall 187 25 mm nominal bore 188 32 mm nominal bore 189 50 mm nominal bore 190 Providing and fixing G.I. pipes(IS:1239 Heavy Class) complete with G.I. fittings including trenching and refilling etc.(For External Riser Pipe) 191 External Work 192 25mm nominalnominal bore 193 32mm nominalnominal bore 194 40mm nominalnominal bore 195 50mm nominalnominal bore 196 65 mm nominal nominal bore 197 Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete : 25 to 40 mm nominal bore 198 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 199 25mm nominal bore 200 32mm nominal bore 201 50mm nominal bore 202 Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 203 20 mm nominal bore 204 25mm nominal bore 205 Providing and fixing 15 mm nominal bore uplasticised PVC connection pipe with brass unions : 45 cm length 206 Constructing masonry Chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design : 207 With common burnt clay F.P.S (non modular) bricks of class designation 7.5 208 Painting G.I. pipes and fittings with synthetic enamel white paint with two coats over a ready mixed priming coat, both of approved quality for new work : 209 25mm diameter pipe 210 32mm diameter pipe 211 50mm diameter pipe 212 Painting G.I. pipes and fittings with two coats of anti-corrosive bitumastic paint of approved quality. 213 25mm diameter pipe 214 32mm diameter pipe 215 40mm diameter pipe 216 50mm diameter pipe 217 65mm diameter pipe 218 Providing and filling sand of grading zone V or coarser grade, allround the G.I. pipes in external work : 219 25mm diameter pipe 220 32mm diameter pipe 221 40mm diameter pipe 222 50 mm diameter pipe 223 65 mm diameter pipe 224 Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) : 225 15 mm nominal bore 226 20 mm nominal bore 227 25 mm nominal bore 228 32 mm nominal bore 229 40 mm nominal bore 230 50 mm nominal bore 231 65 mm nominal bore 232 Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 233 Providing and fixing C.P. brass Short body bib cock of approved quality conforming to IS:8931 with flow rate 2.5 litre per minute at 3 bar: (MAKE-1: JAQUAR, MODEL NO. SHORT BODY BIB COCK : FLR-CHR-5037NG OREQUIVALENT.) 15mm nominal bore 234 Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms with flow rate 2.5 litre per minute at 3 bar. (MAKE-1: JAQUAR, MODEL NO. LONG BODY BIB COCK : FLR-CHR-5047NG OREQUIVALENT.) 15mm nominal bore 235 Providingand fixingC.P. brass angle valve for basin mixture and geyser points of approvedqualityconfirming to IS: 8931. (MAKE-1: JAQUAR, MODEL NO. ANGLE VALVE : AQT-CHR-3057 OREQUIVALENT.) 236 Providing and fixing C.I. double acting air valve of approved quality with bolts, nuts, rubber insertions etc. complete (The tail pieces, tapers etc if required will be paid separately) : 237 50 mm dia 238 Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. 239 Internal work - Exposed on Wall 240 65 mm diameter pipe 241 Painting G.I. pipes and fittings with synthetic enamel white paint with two coats over a ready mixed priming coat, both of approved quality for new work. 242 65 mm diameter pipe 243 Butterfly valve (manual) with C.I bodySS disc nitrile sheet & O ring & PN 16 Pressure rating as specified 100 mm nominal bore 244 65mm dia. 245 Non - return valve with dual plate of CI Body SS plates vulcanized NBR seal flanged end & PN 16 rating as specified. 246 65mm dia. 247 Providing, laying and joining in position HDPE pipes with slipon flange, High density Poly Ethylene pipe and conforming to I.S. 4984-1995 of required grade / class, 16kg/sq.cm pressure and suitable for the respective working pressures with all fittings and specials, e.g. couplings, tees, bends, reducers, screwed adapters, flanged tail pieces, etc., jointing as per manufacturers recommendations, all complete including trenching, backfilling & pressure testing etc. 248 110 mm dia. (OD) (16.0 kgf/sq cm.) 249 160 mm dia. (OD) (16.0 kgf/sq cm.) 250 Providing and fixing motorised butterfly valve with Control Panel & Float Type Magnetic Level Sensors suitable for 220-230 volts AC to operate valve when water level is low in tanks and to close when water level is high in water tanks including necessary cables, conduits, upto junction box (upto 6 mt qty approx.) etc., complete. 32 mm dia 251 Supply installation, testing and commissioning of self-contained Drinking water cooler with inbuilt RO confirming to IS: 1475 with amendment no. 1 to 7, suitable for operation on 230 volts ± 10%, 50 Hz, single phase A.C. supply. The two tank inbuilt (hot & cold) and body casing of the water cooler shall be made out of stainless steel. The water cooler will be of following capacities with two numbers faucets / stop cocks (1 no Normal water & 1 no of hot water): Nominal Storage Capacity - 40 Ltrs. Hot water Storage Capacity - 40 Ltrs. 252 Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design: 253 200 mm diameter S.W. pipe 254 250 mm diameter S.W. pipe 255 Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) up to haunches of S.W. pipes including bed concrete as per standard design : 256 200 mm diameter S.W. pipe / RCC pipe 257 250 mm diameter S.W. pipe / RCC pipe 258 Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design : 180 x 150mm size P-typeWith common burnt clay F.P.S. (non modular) bricks of class designation 7.5 259 Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 260 300mm dia RCC pipe 261 450mm dia RCC pipe 262 Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone- III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone- III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : 263 Inside size 90 x 80 cm and 45 cm deep including CI cover with frame (light duty) 455 x 610mm internal dimensiions total weight of cover and frame to be not less than 38 Kg. ( weight of cover 23 Kg. and weight of frame 15 Kg.), with FPS bricks with class designation 7.5 264 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 265 Inside size 120x90 cm and 90 cm deep including C.I. cover with frame (medium duty) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg (weight of cover 58 kg and weight of frame 58 kg) : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 266 Extra for depth for manholes: Size 90 x 80 cmWith common burnt clay F.P.S. (non modular) bricks of class designation 7.5 267 Size 120x90 cm With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 268 Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS : 10910 on 12mm dia steel bar conforming to IS : 1786 having minimum cross section as 23 mmx25mm and over all minimum length 263 mm and width as 165mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufactures permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design. 269 Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement and making necessary channels for the drain etc. complete : For pipes 350 to 450 mm diameter 270 Constructing brick masonry road gully chamber 50x45x60cm with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) including 500x450mm precast RCC horizontal grating with frame complete as per standard design. With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 271 Excavating trenches of required width for pipe, cables etc including excavation for sockets ,& dressing of sides ,ramming of bottoms ,depth upto 1.5m including getting out the excavated soil,& then returningthe soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming ,watering, etc and disposingof surplus excavated soil as directed, within lead of 50m. All kinds of soil Pipes, cables etc exceeding 80 mm dia but not exceeding 300 mm dia 272 Excavating trenches of required width for pipes, cables, etc including excavation for sockets,depth upto 1.5 m, including getting out the excavated matterials, returning the soil as requred in layers not exceeding 20 cm in depth including consolidating each deposited layers by by ramming, watering,etc. and stacking serviceable material for measurements and disposal of unserviceable matterial for measurement and disposal of unserviceable matterial as directed within a lead of 50m: Ordinary rock Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia 273 Hard rock (requiring blasting) Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia 274 Earth Work in excavation by mechanical means (Hydraulic / excavator ) manual means over area (exceeding 30 cm in depth ,1.5m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50m and lift upto 1.5m, as directed as engineer incharge. 275 Ordinary Rock 276 Hard Rock(requiring blasting) 277 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 278 1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size). 279 Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer –in-charge, upto 90 metre depth below ground level. All types of soil 400 mm dia. 280 Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer –in-charge. 200 mm nominal size dia. 281 Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 200 mm nominal size dia. 282 Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge. 283 Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by V notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge. 284 Providing and fixing suitable size threaded mild steel cap/shoe or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: 200 mm dia 285 Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete. 200 mm clamp. 286 Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I). 200 mm dia 287 Butterfly valve (manual) with C.I bodySS disc nitrile sheet & O ring & PN 16 Pressure rating as specified. 80 mm dia. 288 Non - return valve with dual plate of CI Body SS plates vulcanized NBR seal flanged end & PN 16 rating as specified. 289 80 mm dia. 290 Providing and fixing 80mm dia GI pipes to IS:1239 heavy class with fittings. 291 Supply, Lowering, installation & testing of KSB make submersible pumping set with 10 HP motor 18 stage pump suitable for maximum capacity of 20 m3 hr. at 100 mtr. Head respectively. With Three Phase. 292 Providing & fixing cable 6 sq.mm. From submersible pump to panel board. 293 Providing & fixing Panel Board for submersible pump fitted with DOL starter ammeter, voltmeter single phase preventer standard/indo/cop make MCB of off switch push bottom duly wired and made out of 16/18 SWG sheet. 294 Earth work in excavation by mechanical means (Hydraulicexcavator) / manualmeansoverareas(exceeding30cmindepth.1.5minwidthas well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m, disposed earth to be levelled and neatly dressed. 295 All kinds of soil 296 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. 297 Extraforeveryadditionalliftof1.5morpartthereofinexcavation /banking excavated or stacked materials. 298 All kinds of soil 299 Providingandlayinginpositioncementconcreteofspecifiedgrade excluding the cost of centering and shttering - All work up to plinth level 300 1:4:8(1Cement:4coarsesand:8gradedstoneaggregate40mm nominal size) 301 Centering & shuttering including strutting, propping etc. and removal ofform work for: 302 Foundations, footings, bases of columns etc. for mass concrete. 303 Lintels, beams, plinth beams, girders, bressumers and cantilevers 304 Suspended floors, roofs, landings, balconies and access platform. 305 Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. 306 SteelreinforcementforR.C.C.workincludingstraightening,cutting,bending, placing in position and binding all complete upto plinth level. 307 Thermo-Mechanically Treated bars. 308 Providingandlayinginpositionmachinebatchedandmachinemixed design mix M-25 grade cement concrete for reinforced cement concrete work,usingcementcontentasperapproveddesignmix,including pumping of concrete to site of laying but excluding the cost of centering, shuttering,finishingandreinforcement,includingadmixturesin recommended proportions as per IS: 9103 to accelerate, retard setting of concrete,improveworkabilitywithoutimpairingstrengthanddurability as per direction of Engineer-in-charge. 309 All works upto plinth level 310 6mmcementplaster1:3(1cement:3finesand)onceiling/R.C.C. Beams etc. 311 Neat cement punning. 312 Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers. 313 Providingandlayingnon-pressureNP2class(lightduty)R.C.C.Pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 314 150 mm dia. R.C.C. pipe 315 Providing and fixing soil, waste and vent pipes 316 100 mm dia 317 Sand cast iron S&S pipe as per IS: 1729 318 Providing and fixing terminal guard : 100 mm Sand cast iron S&S as per IS - 3989 319 Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS : 10910, on 12 mm dia steel bar conforming to IS : 1786,havingminimumcrosssectionas23mmx25mmandoverall minimum length 263 mm and width as 165 mm with minimum 112 mm spacebetweenprotrudedlegshaving2mmtreadontopsurfaceby ribbing or chequering besides necessary and adequate anchoring projectionsontaillengthon138mmasperstandarddrawingand suitabletowithstandthebendtestandchemicalresistancetestasper specifications and having manufactures permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cmcementconcreteblock1:3:6(1cement:3coarsesand:6graded stone aggregate 20 mm nominal size) complete as per design. 320 Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality 19.19.1 L D- 2.5 321 Rectangular shape 600x450 mm internal dimensions 322 Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design. 323 With common burnt clay F.P.S. (non modular) bricks of class designation7.5 324 Constructingsoakpit1.20x1.20x1.20mfilledwithbrickbatsincluding S.W.drainpipe100mmdiameterand1.20mlongcompleteasper standard design. 325 Constructingbrickmasonrycircularmanhole1.22minternaldiaatbottom and 0.56 m dia at top in cement mortar 1:4 (1 cement :4 coarse sand)insidecementplaster12mmthickwithcementmortar1:3(1 cement:3coarsesand)finishedwithafloatingcoatofneatcement foundationconcrete1:3:6(1cement:3coarsesand:6gradedstone aggregate 40 mm nominal size) and making necessary channel in cement concrete1:2:4(1cement:2coarsesand:4gradedstoneaggregate20 mmnominalsize)finishedwithafloatingcoatofneatcement,all complete as per standard design : 326 1.68mdeepwithSFRCCoverandframe(heavydutyHD-20gradedesignation)560mminternaldiameterconformingtoI.S.12592,total weightofcoverandframetobenot lessthan 182kg. fixedin cement concrete1:2:4(1cement:2coarsesand:4gradedstoneaggregate20 mmnominalsize)includingcentering,shutteringallcomplete. (Excavation,footrestsand12mmthickcementplasterattheexternal surface shall be paid for separately) : 327 With common burnt clay F.P.S. (non modular) bricks of class designation7.5 328 Extradepthforcirculartypemanhole1.22minternaldia(atbottom)beyond 1.68 m to 2.29 m : 329 With common burnt clay F.P.S. (non modular) bricks of class designation7.5 330 Excavatingtrenchesofrequiredwidthforpipes,cable,etc including excavation for sockets and dressing of sides, ramming of bottoms, depth upto 1.50m including getting out the excavated soil & then returning the soilasrequired,inlayersnotexceeding20cmindepthincluding consolidating each deposited layer by ramming, watering, etc & disposing of surplus excavated soil as directed within a lead of 50m. 331 All kinds of soil 332 Pipes cables etc. exceeding 80 mm dia. But not exceeding 300mm dia. 333 Providing, layingandjointingglazed stone warepipes grade class SP-1with stiffmixtureofcementmortarin theproportionof1:1 (1cement :1 fine sand) including testing of joints etc complete. 150 mm diameter 334 Providingandlayingcementconcrete 1 : 5 : 10 (1 cement : 5 coarsesand : 10 gradded stoneaggregate40 mm nominal size) alround S.W. Pipesincludingbed concrete as per standard design. 150 mm diameter S.W.Pipe 335 Earthwork in excavation by mechanical means ( Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift up to 1.5m, including getting out the excavated soil and disposal of surplus excavated soil as directed, with in a lead of 50m. All kind of soil 336 Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials 337 All kinds of soil 338 Qty for 1.5-3.0 M depth RWH & Desilt Chamber 339 Qty for 3.0-4.5 M depth RWH-Rate 2 Times 340 Qty for 4.5-5.75M depth-RWH -Rate-3 Times 341 Providingorange color safety foot rest of minimum 6mm thickplasticencapsulated as per IS : 10910 on12mm dia steelbar conformingto IS :1786 having minimum cross section as 23mm x 25mm and over allminimum length 263mm andwidth as 165mmwith minimum 112mm space between protrude legshaving2mm tread on top surface by ribbing or chequering besides necessary andadequate anchoring projections on tail length on 138mmas per standard drawing and suitable to with dtand the bendtest andchemical resistancetest as per specifications and havingmanufacturespermanent identification make to be visible even afterfixing, including fixing in manholes with 30x20x15cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) complete as per design. 342 12 mm cement plaster of mix : 1:4 (1 cement: 4 coarse sand) 343 12 mm cement plaster finished with a floating coat of neat cement of mix : 344 1:3 (1 cement: 3 fine sand) 345 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 346 1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) 347 Brick work with common burnt clay modular bricks of class designation 7.5 in foundation and plinth in: 348 Cement mortar 1:6 (1 cement :6 coarse sand) 349 Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge, upto 90 metre depth below ground level. 350 All types of soil 351 300 mm dia 352 Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge. 353 200 mm nominal size dia 354 Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge.200 mm nominal size dia 355 Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. 356 Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. 357 Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge. 358 Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge 359 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size) 360 Centering and shuttering including strutting, propping etc. and removal of form for 361 Suspended floors, roofs, landings, balconies and access platform 362 Edges of slabs and breaks in floors and walls 363 Under 20 cm wide 364 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. 365 TMTsteel bars 366 Providing, fixing, commissioing, testing and of open well submersible pump for each pump IP 58 protected electric enclosure comprising of 2 Nos. Electrical Driven Horizontal pumps with all accessories coupled to motor suitable for operation on 200-240 volts, 1 phase 2900 RPM. motor with SS 304 body all accessories such as NRVs, valves, common delivery header complete in all repsects. Pumps shall be suitable for 200-240volts 1 phase 50 Hz A.C supply & shall be having the following specifications. Moc of pump -Impeller- CI, csing - CI , shaft- SS 410. Delivery header including all GI pipes, CI valves, CI NRV, bourden type Pressure gauge & accessories complete. 367 All accessories for running two pumps with dry running protection etc. 368 FOR DOMESTIC TRANSFER PUMP 369 No. ofPumps: 2 (1 Working + 1 Stand by ) 370 Capacity:120 LPM 371 Head :30m 372 FOR GARDEN IRRIGATION PUMP 373 No. ofPumps: 2 (1 Working + 1 Stand by ) 374 Capacity:140 LPM 375 Head :30m 376 Submersible single stage single entry pumps with C.I.body and C.I. two vane enclosed type impeller connectedto TEFC submersible motor for 415 volts, 3 phase, 50 cycles including MCC panel with level controllers, auto control, sequential change over facility with one proper working at low level & two proper working at high level with an audible alarm including all interconnectivity cables, with both pumps connected to common outlet header including valves, non return valves, lifting chains etc. complete in all respect 377 SUBMERSIBLE UNDER GROUND FOR BOREWELL 378 No. ofPumps: 1 (1 Working ) 379 Capacity:160 LPM 380 Head :60 m 381 SUBMERSIBLE UNDER GROUND FOR BOREWELL 382 No. ofPumps: 1 (1 Working ) 383 Capacity:160 LPM 384 Head :60 m 385 Supply installation testing and commissioning of filtration plant for kund cap. 50cum/hr. including pumps, filters, piping , valves and pumps complete in all respect. 386 Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, up to 90 metre depth below ground level. 387 All Types of Soil 388 300mm dia 389 Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, beyond 90 metre & upto 150 metre depth below ground level. All Types of Soil 300mm dia 390 Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge. 391 200 mm nominal size dia 392 Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 393 200 mm nominal size dia 394 Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge. 395 Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by V notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge. 396 Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: 200 mm dia 397 Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete. 200 mm clamp. 398 Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I). 200 mm dia 399 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit with modular switch modular plate suitable GI box and earthingthe point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc.as required. 400 Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. 401 Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steelconduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required. 402 Wiring for power plug points with 2 x 4 sq.mm. FRLS PVC insulated, Cu. Conductor, single core cable in surface/ recessed steel conduit along with 1 No. 4 sq.mm. FRLS PVC insulated copper conductor single core cable for loop earthing as required. 403 Wiring for light plug points / power plug points with 4 x 4 sq.mm. FRLS PVC insulated, Cu. Conductor, single core cable in surface/ recessed steel conduit along with 2 Nos. 4 sq.mm. FRLS PVC insulated copper conductor single core cable for loop earthing as required. 404 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed Steel conduit as required 405 2 x 1.5 sq.mm. + 1 x 1.5 sq.mm. earth wire. 406 2 x 6 sq.mm. + 1 x 6 sq.mm. earth wire 407 2x10 sq. mm + 1x6 sq. mm earth wire 408 4 X 16 sq. mm + 2 X 6 sq. mm earth wire 409 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 410 Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required. 411 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. 412 Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A C curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. 413 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. 414 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. 415 Supplying and fixing brass batten/ angle holder including connection etc. as required. 416 Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. 417 Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing. 418 Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. 25 mm 419 SITC of Input power : 20W LED, compact and minimilist surface mounted designed for ceiling & pendant mount. Beam angle 110°(Fixed). Luminaire made of extruded anodised aluminium (grade 6063) of high corrosion resistance, polycarbonate end caps and non corrosive stainless steel fasteners. Polycarbonate diffuser. Protection class IP20. Available colour temperature 3000K / 4000K / 5700K, Colour rendering index (CRI)>80. SDCM = 3 MacAdam. K-Lite LED module with expected service life of at least 50,000 operating hours. Prewired with LED driver and suitable for operating on 240V, 50Hz single phase ac supply. Driver efficiency >80%, Power factor>0.95, THD<10%, Surge protection 3KV. Luminaire dimension : 1200mm length x 43mm width x 52mm height. CE & BIS Certified. Inhouse NABL accredited lab.Make :- K-Lite /Ligman/ Unilamp 420 SITC of Input power : 18W led, ceiling mounted compact downlight. Beam angle 15° / 25° / 40°. Luminaire made of extruded aluminium, pressure die-cast aluminium alloy of high corrosion resistance and non corrosive stainless steel fasteners. Clear toughened glass of 4mm thickness. Gravity die cast aluminium plate for surface mounting on ceiling. Hybrid optics with lens & mirror finish pure aluminium reflector combination for higher efficiency, lower optical losses with optimum glare suppression. Single cable entrance via PG7 cable gland. Protection class IP65. Mechanical resistance IK07. Pure polyester powder coated graphite grey / anthracite grey / jet black. Available colour temperature 3000K / 4000K, Colour rendering index (CRI)>80. SDCM-3 MacAdam. K-Lite LED module with expected service life of at least 60,000 operating hours. Prewired with LED driver and suitable for operating on 240V, 50Hz single phase ac supply. Luminaire dimension : 100mm diameter x 150mm height. CE & BIS Certified. Inhouse NABL accredited lab. Make :- K-Lite /Ligman/ Unilamp 421 Supply, installation, testing & commissioning of 595mm/600mm mm long surface mounting type LED fitting with diffuser having a lumen output not less than 1100 lumens, CCT 4000K and LED efficacy better than 110 lumen/ watt with opal diffuser in polycarbonate complete with CRCA / Pressure Die Cast Aluminium Housing and life of 50K burning hours (L 70) at 30 deg , THD =10%, CRI better than 80 with inbuilt protection against short circuit, over voltage protection and surge protection of up to 2 KV including connections etc. as reqd. 422 Supplying and fixing of 250 mm sweep Exhaust fan with all accessories suitable for operation single phase 230 volt 50 cycle per second per sec. AC supply etc. as required. in the existing opening, including making the hole to suit the size of the above fan, making good the damage, connection, testing, commissioning earthing etc. as required. 423 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. 424 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 425 6 way , Double door 426 12 way, Double door 427 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 428 8 Way (4+24), Double Door 429 Supplying and fixing Cable End Box (Loose Wire Box) suitable for following single pole and neutral, sheet steel, MCB distribution board, 240 Volts, on surface/ recess, complete with testing and commissioning etc. as required. 430 For 6 way, Double door SPN MCBDB 431 For 14 way, Double door SPN MCBDB 432 Supplying and fixing Cable End Box (Loose Wire Box) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 Volts, on surface / recess, complete with testing and commissioning etc.as required. 433 For 8 way, Double door TPN MCBDB 434 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole 435 Supplying and fixing following rating, double pole, 240 volts, MCB complete with connections, testing and commissioning etc. as required. 436 25 Amp DP MCB 437 40 Amp DP MCB 438 Supplying and fixing of following rating, 240/415 volts, C curve, four pole miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63Amp FP MCB 439 Supplying and fixing of following rating double pole (Single phase and neutral) 240 volts, residual current circuit breaker (RCCB), having a current sensivity current 100 miliampere in the existing MCB DB complete with connections, testing & commissioning etc. as required. 440 25 Amps 441 40 Amp 442 63 Amp 443 Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. 444 Design, Manufacturing, Supply, Installation, Testing & Commissioning of cubicle type totally enclosed free standing / Wall mounted type moisture, dust and vermin proof compartmentlized Floor Distribution Panel made out of 2.0 mm thick of Main members & front cover 1.6 mm thick CRCA sheet complete with internal wiring with suitablesize wires / cable, interconnection, painting complete as per specification & drawing. All the Multi Function Meter / KWH Meter shall be with RS 485 port / SCADA or BMS Connectivity. 445 The MCCB rating up to 250A shall have thermal megnatic based adjustable over current, short circuit protection and above 250A MCCB shall have microprocessor based adjustable over current, short circuit, earth fault protection. 446 All Main Distribution board / Sub Distribution board / Meter boards which are located inside various blocks shall be partially Type Tested assemblies (PTTA) as per conforming to IEC-61439-1 447 The Moulded Case Circuit Breaker shall have a minimum fault breaking capacity (Ics) of not less than 35 KA & 25KA RMS for one second at 415 volts for MDB / SDB respectively. MCCB‘s above 63A should be provided with Copper & procader terminals. Incomer of Meter Board shall have a minimum short circuit breaking capacity (Ics) of 25KA for one second at 415volt. 448 ELECTRICAL PANEL 449 INCOMING 450 1 No. 125 Amp FP Moulded Case Circuit Breaker. 451 1 Set of phase indicating lamps with MCB. 452 1 Set of ON/OFF indicating lamps with MCB. 453 1 No. Digital MFM with CTs. 454 BUSBAR 455 150 Amp TPNaluminium busbar with coloured heat shrinkable sleeve. 456 OUTGOING 457 9 Nos. 40 / 63 Amp TPN Miniature Circuit Breaker. 458 3 Nos. 25 / 40 Amp DP Miniature Circuit Breaker. 459 Panel described as above 460 Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. 461 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. 462 Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. 463 Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required. 464 Providing and fixing 32 mm X 6 mm G.I. strip on surface or in recess for connections etc. as required. 465 Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. 466 Supplying following 1.1kV grade, heavy duty XLPE insulated PVC Sheathed Aluminum ConductorFRLS type armoured cables suitable for 415V, 50Hz, AC system, with inner and outer PVC sheath, outer sheath provided with FRLS insulation, galvanised steel armouring (round or flat as mentioned) and with all components as mentioned in BOQ, specifications and schedule, complete etc. as required. 467 3.5 core,50 sq.mm. 468 4 core,4 sq.mm. 469 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. 470 Upto 35 sq. mm 471 Above 35 sq. mm and upto 95 sq. mm 472 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required. 473 3½ X 50 sq. mm (35mm) 474 4 X 10 sq. mm (25mm) (Also Used for 4 X 6 sq.mm) 475 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.63 mm dia 476 Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 100 mm width x 50 mm depth x 1.6 mm thickness 477 Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray “bends” (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.100 mm width x 50 mm depth x 1.6 mm thickness 478 Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray “Tee” (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.100 mm width x 50 mm depth x 1.6 mm thickness 479 Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design :Inside dimensions 455x610 mm and 45 cm deep for single pipe line : 480 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 481 Inside dimensions 600x 850 mm and 45 cm deep for pipe line with three or more inlets : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 482 Extra for depth beyond 45 cm of brick masonry chamberFor 455x610 mm size With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 483 Extra for depth beyond 45 cm of brick masonry chamberFor 600x850 mm size With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 484 SITC ofIn-Ground 3000K, 4000K, 5700K 240Vac CRI >80 MacAdam step 3 Input power : 9W led DimensionØ173 x 220 mm Beam Angle : 40° (Tiltable 20°) Electronic driver ON/OFF CE and BIS, IP rating IP67 Die-Cast aluminium alloy housing (grade ADC12 with test certificate). 316 grade stainless steel front ring. Silicone seal gasket. SS fasteners. Mechanical resistance IK09. Pure polyester powder coated process : Acid treatment & pure polyester powder coating. ABS plastic installation housing for preparing the recess opening in ground. The luminaire are fixed in recess installation housing by stainless steel screws. Clear toughened glass diffuser with controlled upward light emission. Lamp fixed position This luminaire contains built-in LED modules. LED modules are engineered accordingly to the existing regulations of Lumen Maintenance (LM80) and Technical Memorandum (TM21), Lifespan of the luminaire > 60,000 hours at 40°C. Operating ambient temperature range is from -15°C to +50°C. Driver efficiency >80%, power factor >0.90, THD <15%, Surge protection 2KV.Inhouse NABL accredited lab.Make :- K-Lite /Ligman/ Unilamp 485 SITC ofInput power : 18W,surface mounted compact spot light designed to provide directional light. Beam angle 15° / 25° / 40°. Luminaire made of pressure die cast aluminium alloy of high corrosion resistance and non corrosive A2 stainless steel fasteners. Clear toughened glass of 4mm thickness. Hybrid optics with lens & mirror finish pure aluminium reflector combination for higher efficiency, lower optical losses with optimum glare suppression. Swivel range of 0° - 90°. Single cable entrance M10 cable gland. Protection class IP66. Mechanical resistance IK06. Pure polyester powder coated graphite grey / anthracite grey / jet black. Available colour temperature 3000K / 4000K, Colour rendering index (CRI)>80. SDCM-3 MacAdam. K-Lite LED module with expected service life of at least 60,000 operating hours. Prewired with LED driver and suitable for operating on 240V, 50Hz single phase ac supply. Luminaire dimension : 160mm length x 100mm width x 154mm height. CE & BIS Certified. Inhouse NABL accredited lab Make :- K-Lite /Ligman/ Unilamp 486 SITC of Flexible LED Strip 3000K, 4000K, 6000K24Vdc CRI >80 MacAdam step 3 Input power : 12W led Dimension1000 x 12 mm Beam angle : 120° Electronic driver ON/OFF (External driver) CE and BIS, IP rating IP67. Copper coated flexible strip, Silicone moulded diffuser, End cap . Silicone moulded diffuser This luminaire contains built-in LED modules. LED modules are engineered accordingly to the existing regulations of Lumen Maintenance (LM80) and Technical Memorandum (TM21), Lifespan of the luminaire >10,000 hours at 40°C. Operating ambient temperature range is from -15°C to +50°C. Driver efficiency >85%, Surge protection 3KV.Inhouse NABL accredited lab. Make :- K-Lite /Ligman/ Unilamp 487 FEEDER PILLAR(OUTDOOR TYPE) 488 Design, Manufacturing, Supply, Receiving, Unloading, Shifting, installation, testing & commissioning of cubicle type totally enclosed free standing type moisture, dust, vermin & weather proofFloor Distribution Panel made out of 2.0 mm thick & front cover 1.6 mm thickCRCA sheet complete with followingequipments, includingdigital ammeter with inbuilt ammeter selector switch, digital voltmeter with inbuilt voltmeter selector switch, indicating lamps, CTs, internal wiring with suitablesize wires / cable, MS Angle stand for installation, RCC foundation, interconnection, painting complete as per specification & drawing. 489 INCOMING 490 1 No. 40 Amp FP Moulded Case Circuit Breaker. 491 1 No. 0 to 500 Volt digital voltmeter with inbuilt selector switch. 492 1 No. 40 Amp digital ammeter with inbuilt selector switch and CTs. 493 1 Set of phase indicating lamps with Single Pole MCB. 494 1 Set of ON / OFFindicating lamps with Single Pole MCB. 495 BUS BARS 496 100 Amp TPNaluminium busbar. 497 OUTGOING 498 1 Set 24 Hrs TSQ Timer 499 1 Set 40 Amp, TP Contactor & A/M switch and Push Button. 500 8 Nos. 20 Amp TP MCB, 10 KA breaking capacity. 501 Panel described as above 502 Supply, Installation, Testing & Commissioning of Cat 6A, 23 AWG (0.57 ? 0.03mm ) Bare Copper Solid Conductor UTP Unshielded LSZH Jacket, ANSI/TIA 568 C.2 Category 6A, Cable shall not have any kind of Non Metallic Barrier Tapeor Metallic Shield inside. Connectivity of Hub room to End Point. Approved Makes:Derwiser/Nexans/Siemon/Systimax 503 Supply, Installation, Testing & Commissioning of Category 6A RJ45 Unshielded Modular Jack, ISO/IEC 11801:2nd edition, EN 50173-1, ANSI/TIA/EIA 568-C.2 Category 6A, IEC 60603-7 (603-7), Universal 110 Impact Tool & Tooless (Both) Termination, Min. 500Mhz Bandwidth, Without Any OEM Proprietary Tool Termination for Data, Voice, & Wi-Fiat user end.Approved Makes:Derwiser/Nexans/Siemon/Systimax 504 Supply, Installation, Testing & Commissioning of loaded 24 port CAT 6A UTP, Transparent shutter jack panel, 1U height, UL-94V-0, clear label marks and earthing plug for CAT6A cable termination at rack end. Approved Makes:Derwiser/Nexans/Siemon/Systimax 505 Supply, Installation, Testing & Commissioning of Cat6A Patch Cord UTP Unshielded LSZH 24AWG Patch Cord, Diameter < 6.2mm,1 Meter, Operating Temperature -20 to +60 Deg C. Patch cord 1 Mtr for rack side switch to jack panel connectivity.Approved Makes:Derwiser/Nexans/Siemon/Systimax 506 Supply, Installation, Testing & Commissioning of Cat6A Patch Cord UTP Unshielded LSZH 24AWG Patch Cord, Diameter < 6.2mm,2 Meter, Operating Temperature -20 to +60 Deg C. Patch cord 2 Mtr for rack side switch to end user connectivity.Approved Makes:Derwiser/Nexans/Siemon/Systimax 507 Supply, Installation, Testing & Commissioning of 1, 2 and 4 port Style (Square) Keystone-Type Shuttered Faceplates for I/O fixing at user side.Approved Makes:Derwiser/Nexans/Siemon/Systimax 508 Supply, Installation, Testing & Commissioning of 15Uwall mount rack with fans , 2 cable managers , satationary shelf , 2 Nos. of hardware pkts. Approved Makes: Derwiser/MTS/Rittal/APC/APW 509 Supply, Installation, Testing & Commissioning of Cat 6A, 23 AWG (0.57 ? 0.03mm ) Bare Copper Solid Conductor UTP Unshielded LSZH Jacket, ANSI/TIA 568 C.2 Category 6A, Cable shall not have any kind of Non Metallic Barrier Tapeor Metallic Shield inside. Connectivity of Hub room to End Point. Approved Makes:Derwiser/Nexans/Siemon/Systimax 510 Supply, Installation, Testing & Commissioning of Category 6A RJ45 Unshielded Modular Jack, ISO/IEC 11801:2nd edition, EN 50173-1, ANSI/TIA/EIA 568-C.2 Category 6A, IEC 60603-7 (603-7), Universal 110 Impact Tool & Tooless (Both) Termination, Min. 500Mhz Bandwidth, Without Any OEM Proprietary Tool Termination for camera at user end.Approved Makes:Derwiser/Nexans/Siemon/Systimax 511 Supply, Installation, Testing & Commissioning of loaded 24 port CAT 6A UTP, Transparent shutter jack panel, 1U height, UL-94V-0, clear label marks and earthing plug for CAT6A cable termination at rack end.Approved Makes:Derwiser/Nexans/Siemon/Systimax 512 Supply, Installation, Testing & Commissioning of Cat6A Patch Cord UTP Unshielded LSZH 24AWG Patch Cord, Diameter < 6.2mm,1 Meter, Operating Temperature -20 to +60 Deg C. Patch cord 1 Mtr for rack side switch to jack panel connectivity. Approved Makes:Derwiser/Nexans/Siemon/Systimax 513 Supply, Installation, Testing & Commissioning of Cat6A Patch Cord UTP Unshielded LSZH 24AWG Patch Cord, Diameter < 6.2mm,2 Meter, Operating Temperature -20 to +60 Deg C. Patch cord 2 Mtr for rack side switch to end user connectivity.Approved Makes:Derwiser/Nexans/Siemon/Systimax 514 Supply, Installation, Testing & Commissioning of 1, 2 and 4 port Style (Square) Keystone-Type Shuttered Faceplates for I/O fixing at user side.Approved Makes:Derwiser/Nexans/Siemon/Systimax 515 Supply, Installation, Testing & Commissioning of L2+ managed industrial PoE fiber switch with 24*10/100/1000M RJ45 ports and 4*1//10G SFP slot ports, Port 1-24 can support IEEE802.3af/at PoE.Switching capaticy of128Gbps, forwarding Rate 95.23 Mpps, having24 x 10/100/1000BASE-T PoE-plus(RJ45) with maximum PoE output power is 400W, 1 RS232 Console port.32K MAC address. Should have Static Routing ,system logging, Telnet, SSH, SNMP, Network Time Protocol (NTP),and IPv6 features from day 1, Security Feature: Port Isolation, VLAN, MAC, Spanning tree, Multicast, DDM, ACL, QoS: 802.1p (COS), DSCP, SP, WRR, Classification based on source IP, destination IP, and port number etc.Approved Make :Cisco/ Impulse / Juniper / Nexxus 516 Supply, Installation, Testing and Commissioning of Workstation PC: Intel(R) Core(TM) i7-3770 Processor (8M Cache, up to 3.90 GHz); RAM: 8GB (1x8GB) Non-ECC DDR3 1600MHz ; Keyboard: 12 function keys; Chassis: Tower/Workstation; DVD: 8X Slimline DVD+/-RW, Data Only; Dual Graphics Card; Network interface card: Integrated Intel(R) 82579LM Gigabit1 Ethernet LAN 10/100/1000; Hard disk: 250GB, 7200 RPM 3.5 SATA 6Gb/s Hard Drive; Operating system: Windows 10 Professional 64 Bit or latest.Approved Makes: HP / DELL / IBM / LENOVO 517 Supply, Installation, Testing & Commissioning of 8TB Surviellance Hard Disk. Approved Makes: WD /segate /Toshiba/HP 518 Supply, Installation, Testing and Commissioning of Full HD 55 LED Professional Display Panel.Approved Makes: Panasonic / LG/ Sony/ Samsung 519 Supply, Installation, Testing & Commissioning of Pure IP at core server Based voice solution with04 Port Voicemail ,04 Port FXS ,04 Port FXO ,1 PRI Trunk lines (30 Ch) Circuit with CLIP Facility ,28 IP users License ,01 Nos. IP Operator Console, 100 Party Conference ,Speed Dial, Music on Hold , Internal/ External ring difference ,Call Barring, Call Pickup, TEC should be with GR Number, - Should Support Redundant server in active-Active mode.Approved Makes: Tadiran/Arista /Polycom/Toshiba/ Aeonix 520 Supply, Installation, Testing & Commissioning of Type 1 IP Phone 1 VoIP account , Full duplex speaker phone, IPV6, 2xLAN, PoE .Approved Makes: Tadiran/Arista /Polycom/Toshiba/ Aeonix 521 Supply, Installation, Testing & Commissioning of 24 Port PoE Access Switches with switching capaticy of 300 Gbps, forwarding performance 240 Mpps, having 24 x 10/100/1000BASE-T PoE-plus(RJ45) with minimum PoE budget of 720W and 4x 10G SFP+ uplink ports . Should support min 4GB internal DRAM, 8GB internal Flash memory, 64K MAC address, 8K Multicast Routes, Should have static Routes from day 1.Approved make - Cisco / Juniper /Impulse / Nexxus/Arista 522 Supply, installation, testing and commissioning of 5 MP Bulletcamera ,ONVIF profile S ,G & T . UL , CE , FCC Certified ,1/2.7” Progressive Scan CMOS , 3.6 mm fixed lens , Quad stream support,min illumination : Color 0.05lux @ F1.2(AGC ON) ; B/W 0 lux @ IR ON , Shutter speed : Shutter speed :1 / 5s ~ 1 / 100,000 s ,WDR , Compression : H.265/H.265+/H.264/H.264+ .SD card support up to 256GB, frame rate : Main stream should support 25 fps@5MP , Edge analytics : Customer Flow staistics,Cross Count Heat Map, Human & Vehicle Detection, Pedestrian Intrusion Detection & Line cross Detection. Queue length detection, Regional population statistics, SOD-Stationaary Object Detection. , In built IR LED , IR Distance upto 30 meters , IP 66 , POE. Approved Makes : Allgovision/ Impulse / Avigilon / Cisco/ Axis 523 Supply, installation, testing and commissioning of32 channel NVR , ONVIF compliant , recording bandwidth 640 Mbps , output interface 1 HDMI (up to 4K), 1 VGA, Alarm in/out : 16chin / 4chout , 1 X RJ45 ethernet , iOS smartphone support , 8 HDD support, each HDD slot support upto 8 TB HDD , 1x3.0 USBfor backup /upgrade , 2x 2.0 USB for mouse .Edge analytics of poposed cameras must be integrated with NVR .Artificial Intelligence Support having face recognition with compatible deep learning supported cameras, AI-Face registered quantity upto 10,000,A.I maximum captured quantity200,000. UL,CE,FCC certified. Approved Makes : Allgovision/ Impulse / Avigilon / Cisco/ Axis 524 GST Extra as applicable
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
Uttar Pradesh View Result →
22.
Defence #9353987 Technical Bid
Tender For Provision Of Work Services For Solar Power Plant At Af Stn Adampur; 1 SCHEDULE `A PART - I (Building Works) is not prepriced by MES and prepriced rates indicates 0.0 under column 6 signified this fact only. 2 Construction of SUB STATION BLDGcomplete all as specified and shown on drawings. 3 NOTE: Schedule ‘A’ Part IIto X under Ser No. 2.01to 2.10 are Prepriced by MES. 4 Lump sum price worked out by the Contractor for “SITE CLEARANCE, EXCAVATION AND EARTH WORK” as listed in Schedule ‘A’Part II 5 Lump sum price worked out by the Contractor for “INTERNAL ELECTRIFICATION as listed in Schedule ‘A’Part III 6 Lump sum price worked out by the Contractor for “INTERNAL WATER SUPPLY as listed in Schedule ‘A’Part IV 7 Lump sum price worked out by the Contractor for “SOLAR POWER PLANT” as listed in Schedule ‘A’Part V 8 Lump sum price worked out by the Contractor for “ROAD/PATH/CULVERT” as listed in Schedule ‘A’Part VI 9 Lump sum price worked out by the Contractor for“EXTERNAL WATER SUPPLY ” as listed in Schedule ‘A’Part VII 10 Lump sum price worked out by the Contractor for“EXTERNAL ELECTRIFICATION ” as listed in Schedule ‘A’Part VIII 11 Lump sum price worked out by the Contractor for“SEWAGE DISPOSAL ” as listed in Schedule ‘A’PartI IX 12 Lump sum price worked out by the Contractor for“AREA DRAINAGE” as listed in Schedule ‘A’Part X 13 Lump sum price worked out by the Contractor for“FENCING AND GATE” as listed in Schedule ‘A’Part XI 14 SCHEDULE `A PART - XII MISC ITEMSis not prepriced by MES and prepriced rates indicates 0.0 under column 6 signified this fact only. 15 INTERNAL ELECTRIFICATION 16 S&F LED light fitting 1 x 10 Watt, 220V, AC,box type with driver, holder incl making connection with three core flexible copper conductor cable 0.5 sqmm from ceiling rose complete all as specified and directed. 17 S&F LED security light fitting 20 watt, input 110 to 220 voltsas per IP 65 luminaries comprising of rectangular shape, high pressure die cast aluminium housing, with weather proof gaskets for lamp and driver compartment with GI pipe 25 mm dia light grade bend to shape including necessary fixing arrangement complete all as specified and directed. 18 SOLAR POWER PLANT 19 Design, supply, erecting, installation, testing & commisssioning of ON Grid connected, ground mounted solar PV Plant of 737 KWp capacity at standard condition (irradience temp etc) at AF Stn Adampur (Longitude 75° 44 20 E, Lattitude 31° 26 14 N & elevation 244.54 mtr). The ripple content shall not exceed 3% on DC and harmonics shall not be more than 3%, Micro processor based directional & revese power flow protection shall be provided to ensure isolation of SPV from Grid at the time of fault including all connected equipments required for their smooth functioning comprising of the following major componenets all as specified:- 20 Supply, erecting, installation, testing & commissioning of framed dual glass bifacial Solar modules each consist of 144 cells (12x6+12x6), size of module 2278mm (L) x 1134mm (W) x 33mm (T) or as approved, M10 TOPCon N type mono bifacial solar cells not less than 585 Wpeach, front glass 2mm low iron printed semi tempered glass, back glass 2mm low iron printed semi tempered glass, PID free & UV resistant encapsulate, IP68 weatherproof PPO junction box, compatible with IP68 rated MC4 connector alogwith 1400mm DC, Copper cable of 4sqmm size, anodized aluminium framehaving efficieny more than 22.5% at standard test condition. These panels shall be suitably fixed on Module mounting structure. The electrical Data of panel at standard test condition (STC) 1000W/m² irradiance, air mass 1.5 & 25°C cell temperature shall be as under:-(i) DC peak power (Pmax) - not less than 585 Wp. (ii) DC peak voltage (Vmp) - 44.15V (Approximate). (iii) DC peak current (Imp) - 13.25A (Approximate), (iv) Short circuit Current - 13.99A (Approximate). (v) Open circuit Voltage - 52.70V (Approximate). (vi) Module efficiency - 22.65% (Approximate). (vii) Operating temp range (-) 40°C to 85°C. (viii) Series fuse rating = 30A (Approximate). (ix) Junction box = IP68, weatherproof PPO. (x) IP68 rated MC4 connector compatiable. (xi) Anodised aluminium frame. (xii) front glass 2mm low iron printed semi tempered glass. (xiii) back glass 2mm low iron printed semi tempered glass, PID free & UV resistant encapsulate. (xiv) Sustain heavy snow upto 5400 Pa. (xv) Sustain wind loads upto 2400 Pa. 21 Note :-(a) The PV modules must be tested and approved by one of the IEC authorised test centers. In addn a PV module qualifacation test certificate as per IEC standard, issued by ETDC Bangalore or Solar Energy Centre will also be valid. (b) Warranty on output and life of structure shall be as under :-(i) Output wattage of PV modules shall not be less than 90% at the end of 10 years and 80% at the end of 25 years.(ii) The mechanical structure, electrical works and overall workmanship of the grid solar power plant must be warranted for a minimum of 5 years.(iii) Grid solar PV power plant must install necessary equipment to measure solar radiation, ambient temperature, solar energy meter 11 KV to measure grid solar power generation, wind speed and other weather parameters contnuously. Simullataneuosly measurement of the generation of DC power as well as AC power from the plant must be done. 22 (c) Each module shall have RFID tag bearing the following details. RFID reader shall be provided by contractor :-(i) Name of manufacturer of PV module (Should be made in INDIA). (ii) Name of manufacturer of solar cell (Should be made in INDIA). (iii) Month and year of manufacture (Separately for cell & module). (iv) Country of origin separetly for cell & module (Made in INDIA only). (v) Peak Wattage, Im, Vm and fill factor of the module. (vi) Date of year of obtaining IEC PV module, qualification, certificate. (vii) Unique serial no and model no. of Module. (viii) I-V curve of module. (ix) Name of the test Lab issuing IEC certificate. (x) Every module should have PID test report as per latest prevalling norms of MNRE & will be submitted to the GE. (xi) Solar cells & Modules shall meet DCR norms. 23 (d) Provision of earthing and earth strip/cables etc. for earth for solar PV module/Array as per latest IS/MNRE norms to be providied it will be measured and paid seperatly. (e) PV module shall confirm to IEC:61215, IEC: 61730, UL:61730-1 & 2 for construction, testing and safety qualifacation and latest minimum technical specifications. The module shall be manufactured in 2024 or subsquent year. Product warranty shall be for at least 12 years and performance warranty shall be at least 25 years. 24 (f) The contractor will submit the complete design of ON Grid connected Solar PV Plant alongwith complete design details, drawings, calculation sheet and connected documents within one month of acceptance of tender and before procurement of the material. The same shall be submitted to GE after vetting from IITs/NISE for approval of accepting officer. (i) The complete design will submitted to Accepting Officer through CWE for final approval before placing order of the materials to be used in Solar PV Plant. (ii) The test report of modules as per national and international standards and technical data shall be submitted by contractor to GE for approval of accepting officer. (iii) Minimum 0.5% of PV Module shall be tested for all electrical parameters incl efficieny & safety measure by the rep of AO at OEM factory premises before dispatch as per technical data sheet of the manufacturer. (iv) Contractor will submit 2% amount of total quoted amount against item Sl No 4.04 (PV Module) as performance security of PV Module in the form of FDR or BGR in favour of the Accepting Officer which will be refurned to the contractor on successful performance copletion of 25 years of PV Module.(v) Contractor will submit gurantee for at least 25 years performance of PV Module as per CA provision and in case of any manufacturing fault of any PV Module during the performance warranty of 25 years the same shall be replaced by the contractor without any extra cost. (vi) All the modules shall be of same make. (vii) Rates of testing at Factory premises of OEM or MNRE approved Lab are deemed to be included in the quoted rates.(g) Make : MNRE approved and as per list of makes mentioned in Appx D of the tender documents. 25 (viii) The solar power plant shall be got tested/ inspected by third party i.e. NISE or any other Govt approved lab as decided by Accepting officer. Cost of testing and all other arrangement for this shall be made by the contractor without any extra cost.Third party inspection/ testing shall be carried out after execution of complete work and all departmental testing. (ix) Acceptance/ Final test from rep of Accepting Officer shall be carried out after physical completion of solar power plant work.All arragement for this shall be made by the contractor without any extra cost. (x) The following tests shall be carried out: (i) Performance ratio test (ii) CUF (iii) Efficiency test (iv) Irradiance test (xi) All drawings and design duly supported with detail calculation and property of the equipment shall be submitted by the contractor within two months from the date of issue of work order for approval of the Accepting officer. 26 Design, supply, installation, testing & commissioning String PV Inverter of capacity not less than 250 KW. Input DC & output AC specification of the inverter shall be as under :-Input DC. Max input DC voltage not less than-1500V, rated input voltage not less than 1080V, start up voltage 550V, minimum MPPT voltage range 180-1500V DC, MPPT voltage range at full load 800-1300V DC, minimum number of string input 24, minimum number of MPP trackers-12, string per MPPT- 2 Nos, max input current per MPPT shall not be less than 30A, max short circuit current per MPPT shall not be less than 50A. 27 Output AC.Minimum AC output power 250 KVA@30°C, 235KVA @40°C, 220 KVA @ 50°C, max output current not less than 184A, Nominal 3 phase voltage- 800V, minimum Grid voltage range 640-920V, Frequency- 50/60Hz, Grid frequency range - 45~55Hz, Active power adjustment range- 0-100%, THDi- <3%, power factor 0.8 leading-0.8 lagging, 3 phase.Performance.Max efficiency - not less than 99.01%, European weighted efficiency - not less than 98.8%, outdoor string solar power grid tie inverter suitable to convert DC power of solar PV module/array to AC for further feeding to grid & conforming to IEC-61683 for efficiency, IEC-62109 (1&2) or equivalent for safety & IEC-62093 for reliabilty. The inverter shall be self-communicated with pulse width modulation (PWM) technology and shall be capable to synchronize with grid maximum in 1 minute. Maximum Power point tracker (MPPT) conforming to IEC-62093 shall be intergrated in the inverter to maximize energy drawn from the solar PV array. 28 The inverter shall have following protections:- (i) DC reverse polarity protection. (ii) Anti Islanding protection. (iii) Leakage current protection. (iv) Ground fault monitoring. (v) PV array string fault monitoring. (vi) Zero voltage ride through. (vii) DC switch. (viii) Anti PID protection. (ix) AFCI protection (Arc Fault Circuit Interrupter). (x) Over voltage. (xi) Under voltage. (xii) Overload. (xiii) Shorcircuit. (xiv) Earth fault. (xv) Under frequency and over frequency.Protection class/Overvoltage category- I/III. Input/output SPD- PV type-II & AC type-II standard. Electromagnetic compatibility (EMC) as per EN-61000-6-2&4. Safety standard as per IEC62109-1/2, IEC62116, IEC61727, IEC61683, IEC60068(1,214,30). Communication- RS485, USB, Bluetooth, Wi-fi, GPRS, PLC.Inverter shall monitor the following:-(i) DC input voltage (ii) DC input current (iii) DC ripple (iv) DC input power (v) AC output (vi) AC output current (vii) AC output power (viii) AC output frequency (ix) AC output power factor (x) Synchronization status (xi) Grid voltage (xii) Grid frequency (xiii) Grid (ii) Ground fault (iii) PV string fault montioning inverter shall have arrangement for adjusting DC input current & shall trip against sustainable fault down stream and shall not restart till fault is rectified. 29 General specification:- (i) Ambient temperature range - (-) 30°C to (+) 60°C. (ii) Self consumtion power at night - < 2W, Topology- Transformerless. (iii) Degree of protection - IP66. (iv) Allowable relative humidity 0-100%, max operating altitude - not less than 4000M, (v) Noise - <60Db. (vi)Cooling - Smart forced air cooling. (vii) Display - LCD & Bluetooth+App.Rate for PCC foundation including required concreting and steel fixing as instruction and directed by engineer-in-charge are deemed to be included in quoted rates.Isolation method tranformer less smart forced cooling LED display, Rs 485/PLC communication, smart IV Curve Diagnosis, Type II SPD for both DC & AC with 5 years guarantee. Make: HITACHI/Delta/Sungrow.Note:- (i) Contractor shall submit parameter sheet of inverter duly recommended by GE & CWE for approval of AO before placing order to the company. (ii) All the inverter shall be of the same make & model. 30 MC4 CONNECTORSSupply, installation, testing & commissioning of solar MC4 connectors (Male and female both) having copper pin with tin plating with 1500 V DC & not less than 30 Amp. Current suitable for 4/6 sqmm cable, degree of protection IP-68, contact resistance < 2 mili ohm, insulation resistance >500 Mega ohm, insulation material PPO, protection class-II, application class A, standard EN 50521: 2008 TUV certified and shall also meet the requirement of IEC:61984 complete all as specified and directed. Make: Indygreen/Elmax/synergy/Eteilyte Technologies India Pvt Ltd . 31 Modules Mounting Structure (MMS) Design, supply and erect Module mounting structure made up of MS Hot dip Galvanised (80 Micron) as per IS 4759, GI frame Structure to hold approved solar panels mounting with all accessories.Fixing arrangements for fixing the PV solar modules & to withstand minimum horizontal wind speed of 170 km/ hr as per IS. It shall conforming to latest revesion of IS 2062 having Grade of 250 MPA. The MMS design shall be submitted by the contractor and shall be approved by AO. The solar panel shall be fixed at a tilt angle of 31° or as per designed SPV Plant. Note : The design should be similar as per drawing attached. 32 Mounting Structure shall have following specification:-(i) Nut, bolts and supporting structure including module mouting structure shall have to be adequately protected from atmosphere and weather prevalling in the Adampur Air Force Station. All fastners shall be of stainless steel of Grade SS 304.(ii) Two numbers of anti-theft fastners of stainless steel on two diagonally opposite comer of each module shall be provided.(iii) The rep of AO, shall visit the factory site of galvanising for each section of lot of dispatch to collect the samples at random & send the sample duly sealed & signed by him and rep of contractor to nearest NABL accredited Lab for testing. The lot will bedispatched from factory permises only after passing of sample from Lab. In case of failure of sample complete lot will be rejected. The quoted rates are deemed to include these provisions. 33 Note:- (i) cost of interconnecting copper cables along with cable trays (floors/ wall mounted) suitable to accommodate solar grade cables & cables upto invertersshall be measured and paid separately under relevant items. (ii) Earth work and foundation of MMS shall be measured and paid separately under relavent items (iii) MM structure shall be paid as per actual size installed st site. 34 M&L for tinned copper conductor, 6 Sqmm XLPO insulated and sheathed, UV-stabilized, single core multi-stranded DC cables- RED & BLACK (FOR PANEL INTER CONNECTION), complete as all specified below and directed.(1) Construction(i) tinned copper conductor IEC 60228, class-S(ii) Insulation/sheath:- electon beam cross linked halogen free & flame retardant compound (XLPO)(2) Electrical(i) Voltage Test: 6500V as per EN 50395 (ii) Max permissible operating Volatge:- DC 1.5 KV (conductor-conductor, non earthed system)(iii) Nominal Voltage :- AC 0.6/1.1 KV & DC -900/1.5 KV(3) Temperature(i) Amblent temp: (-) 40°C to (+) 90°C (ii) Max conductor temp (-) 40°C to (+) 120°C(4) Strandards & Material properties(i) Fire performance -IEC 60332-1-2(ii) Smoke emission:- IEC 610374/EN 50268-2(iii) Approval :- EN 50618, HIZ272-KMake: Polycab/Havells/Finolex/KEI India/RR KabelNote: (i) Routine testing of cable shall be carried out by rep of AO at the factory premises of OEM, before dispatch. 35 Supply and laying in trenches, 3.3 KV underground cable, XLPE insulated armoured heavy duty electric cable with aluminium conductor 3300 Volts grade, cross sectional area 300 Sqmm, 3.0 core multistranded, confirming to IS-7098 (Part-1):1988 suitable for earthed system including cable connecting lugs, glands,jointing materials etc., laid in trenches, floors, roof, ducts and fixing using clamps, saddle for pole, wall complete all as directed by Eng-in-Charge. (ACDB to LT Panel and LT Panel totransformer). 36 All same as per item No 4.17 above but size of 120 Sqmm 3.0 core (Busbar No 1 to ACDB No 1, Busbar No 2 to ACDB No 2 and Busbar No 3 to ACDB No 3) 37 M&L for 70 Sqmm 3.0 core, 1100 volts grade PVC Copper Cable flexible, conforming to IS 7098 (Part-2):1988 (Inverter No 1 to Busbar No 1, Inverter No 2 to Busbar No 2 and Inverter No 3 to Busbar No 3) complete all as specified and directed by Engr-in-Charge. 38 HT TRANSFORMER (INVERTER DUTY FOR SPV PLANT)Supply, installation, testing & commissioning of copper wound, step up cum inverter duty conforming to IS:2026 or latest IS standard, HT Transformer, outdoor type capacity not less than 1000 KVA, 0.800/11KV, 50 Hz, Dyn 11, ONAN class A for solar application, Star Delta Tapping + 7.5 % to -7.5% @ the step of 2.5% ON load type tap changer, with first filling of transformer oil as per IS:355, ISI marked , duly filtered & Dehydrated and other standard fitting/ accessories including Platform & foundation for Transformer installation as recommended by manufacturer. The total losses (No load + Full load) at 75 deg C shall not be more than 1% of rated capacity of transformer, Impendence 5%. The following are included:-(i) Name, rating & diagram plate. (ii) Tap changing switch. (iii) Earthng terminals. (iv) Lifting lugs. (v) Oil level indicator 150 mm dia with alarm & trip contact. (vi) Oil drain valve with plug (vii) Oil filter valve with plug. (viii) Conservator with oil filling hole with cap. 39 (ix) Thermometer pocket. (x) 4 Dial type thermometer stem type & with MRP. (xi) Air release plug. (xii) Silicagel breather. (xiii) Removable inspection opening on top cover. (xiv) Explosion vent. (xv) Bi-directional CI rollers. (xvi) Arching horn set. (xvii) Winding temperature indicator with alarm & trip contact. (iii) Marshalling box for 03 Nos. (iv) Magnetic oil level gaugue (v) Pressure release valve (PRV) with trip contact. (xviii) Conservator with oil filling hole with cap & drain plug and with bulit in diaphragm to avoid direct air contact with transformer oil. (xix) Oil level indicator with minimum level marking. (xx) HV cable box (xiv) LV cable box (xv) Bucholz relay with control connection upto HT VCB including testing at OEM premises.Note : Cost of PCC foundation as per OEM foundation drawing & necessary earth work (excavation, returning filling & making good to surface) shall be deemed to be included in quoted rate.Make:- GEC (Prolec)/ABB/Siemens/Schneider/ITE Gurgaon/CG Power & solution Ltd. 40 M&L for 50 Sqmm single core, 0.6/1.1 KV PVC insulated and PVC sheathed Copper flexible cable, IS :7098 complete as all specified and direcetd. (LA Top to Earth strip of pit) 41 M&L for 6 sq.mm single core, PVC insulated and PVC sheathed copper flexible cable, IS :7098 complete as all specified and direcetd. (LA Top to Earth strip of pit) 42 M&L for 1 sq.mm , 2 core, RS 485 cable twisted shielded unarmoured copper cable complete as all specified and directed (Data Monitoring Cable for communication) 43 ACDB Panel for 750 KWp Inverters (3x250 KW inverters) Design, supply, installation, testing & commissioning of outdoor type, floor mounted ACDB Panel for 750 KW Inverters having 3 incoming & 1 outgoing, IP-65 protection rating with PCC foundation for civil works (Excavation, cutting, Grouting, PCC etc) Fabrication with 3.15 mm thick CRCA sheet steel, 7 tank power coated, floor mounted panel with 40x40x6mmMS angle stand, cable entry from bottom through gland plates, internal control wiring with suitable size copper cables, cable alley, three numbers 1200 Amps aluminium bus bar EC grade incld heat shrinkable PVC sleeves complete all as specified and directed and having following switchgears :- 44 OUTGOING:-1 No.800 Amp, 3 Pole,50Hz, 3 phase, ACB Drawout type, motorised charging, with microprocessor release, Icu = Ics = Icw 50 KA,suitable for 800 volt, 3 phase, 50 Hz with ACB spreader Link with R,Y,B LED indicating light, digital Multimeter 800 volts CL-1, 3 Nos Metering CT 800/5A TP SPD Type 1+2 40 KA. INCOMING :-3 x 250 Amp, Icu = Ics = 36 KA 3 pole MCCB microprocessr released with spreader links. The panel should contains follwoing metering devices :(a) Volt meter with selecter switch -01(b) Ammeter with selecter switch -01(c) Frequency meter - 01(d) R,Y, BIndication Lamp LED type- 01 Set of three.(e) PT 800V/110V,-01 Set of three.(f) CT 800A/5A, CL-0.2, 5VA- Set of three(g) Auxiliary transformer 50 VA, 800V/230V - 01 NoNote:- Contractor shall submit drg of ACDB panel to GE for approval of accepting officer before procurement. 45 LT Panel for 750 KWp inverters Design, supply, installation, testing & commisssioning of outdoor type, floor mounted LT panel of 3.15mm thcik CRCA sheet steel powder coated for 750 KWp inverters having 1-input & 1- output, IP-65 rating, cable alley with PCC foundation for civil works (excavation, cutting, grouting, PCC etc) TP SPD,type 1+2 40 KA, MCCB extended ROHM, all cable entry from bottom through gland plates, 3 Nos control fuse 16A with base for SPD,three 1200 Amps Aluminium bus bars Ec grade incl heat, shrinkable PVC sleeves, Aluminium busbar links, internal wiring with suitable size copper cables, with 40x40x6mm MS angle stand , 7 tank powder coated, three 6A SP 10KA MCB C Curve etc complete all as shown on drawingscomplete all as specified and directed. 46 INCOMING:-1 No of 800 Amp 3 pole ACB, Icu = Ics = Icw = 50 KA- 800 Volts, drawout type, motorised charging, with microprocessor release ACB/MCCB Spreader links.OUTGOING1 No of 800 Amp 3 pole ACB, Icu = Ics = Icw = 50 KA- 800 Volts, drawout type, motorised charging, with microprocessor release ACB/MCCB Spreader links:- The panel should contains follwoing metering devices :(a) Volt meter with selecter switch -01 No(b) Ammeter with selecter switch -01 No(c) Frequency meter - 01 No(d) R,Y, B Indication Lamp LED type- 01 Set of three.(e) PT 800V/110V,-01 Set of three (f) CT 800/5A, CL -0.2 , 5VA - Set of three(g) Auxiliary transformer 50 VA, 800V/230V -01 No.Note:- Contractor shall submit drg of Panel to GE for approval of accepting officer before procurement. 47 COPPER BUSBAR CHAMBERM&L for outdoor type, floor mounted , vermin proof, totally enclosed bus bar chamber of not less than size 800 mm (H) x 800mm (W) x 600 (D) made out of 3.15 mm thick CRCA sheet , incl three number 300 Amps pure copper busbar having size of 200 MM (w) x 100 MM (thick), 0.5 Mtr length/ phase incld heat shrinkable PVC sleeves, duly supported on insulators, it shall be IP-65 rated. Cable entry from bottom and suitable for input of 70 sqmm, 1.1 KV copper cable and output of 120 sqmm, 1.1 KV XLPE cable, powder coated complete all cable entry from bottom through gland plates all as spceified and directed. 48 MONITORING SYSTEMDesign, Supply, installation, testing & commissioning of monitoring system to monitor the performance of the PV Module & inverter (Power arrray voltage, array current & AC parameters), energy yield temperature, irradiance level, humidity, Air Mass, wind velocity etc, and it could provide flexible interface to facilities PC based inverter monitioing and control via GPRS modem and internet/ethenet connection. This should have include web visulization system and data logger with integrated ethernet port. The monitoring system shall be comprises of following :-(a) 5G based plug and play RTU with smart data logger to connect inverters & sensors - 1 Set. (i) Modbus RS485 RTU. (ii) 2 Analog ports. (iii) Built in memory help store and send data in case of network failure. 49 (b) IP-67 Enclosure box (280mmx190mmx130mm) or as approved with SMPS power supply and other accessories to house the RTU - 01 No.(c) Access to web portal-server charges for 1 years data frequency 10 minutes.(i) Interractive Dashboard. (ii) Single line diagram. (iii) PR analysis. (iv) Solar radiation & weather data. (v) Graphics and reports. (vi) Generation analysis. (vii) Log reporting. (viii) String/MPPT monitoring. (ix) Plant/Inverter performance. (x) Superuser dashboard for centralized monitoring. (xi) Mobile app on android. (d) Weather sensors.(i) Solar radiation sensor with mounting kit - 01 No. (ii) Wind speed sensor with mounting kit - 01 No. (iii) Ambient temperature sensor with mounting kit - 01 No. (iv) Module temperature sensor with mounting kit - 01 No to be provided complete with readouts integrated with the data logging system. 50 (v) Analog to modbus module - 01 No. (vi) Wind direction sensor with mounting kit - 01 No.(e)All in one Desktop computer, 12 th Gen intel core i3, 21.5 inch monitor screen, FHD display, 8 GB RAM, 512 GB SSD with Window 11 including wireless keyboard and mouse complete. Make : HP / Dell/ Lenovo / Microsoft(f)Laser Jet Printer, print speed not less than 18 ppm, power consumption not more than 320 watt, capable to print on A4, A5, B5 & legal size paper, single function including power cable & USBcable, toner, installation CD and user manual complete. Make : HP / Canon/ Xerox 51 Note : The following information shall be displayed in the monitoring system:-(i) Individual module power generation, voltage, current, irradiance and temperature etc.(ii) Individual string power generation, voltage, current, irradiance and temperature etc.(iii) Total power generated of all strings, voltage, current, irradiance and temperature feeding to each invertor. (iv) input voltage, input current, output voltage, output current and power losses of each inverter.(v) Total power, voltage, current, temperature at input of solar transformer, also output parameters such as output voltage and output current of solar transformer. 52 EARLY STREAMER EMISSION (ESE)Supply, installation, testing & commissioning of 5m high, advance active on generating Early Streaner Emission (ESE) lightning arrestors with lightning counter to provide radius of protector of minimum 107 m at level-IV. The lightning arrestors shall conform to IEC 60099-4 or IS 3070 except to the extent modified in the specification. Arrestor shall be hemetically sealed units, self -supporting construction, suitable for mounting on lattice type support structurs complete as specified and directed by the EIC & shown in drawings. 53 Lightning Protection system on protective Early Streamer Emission (ESE) technology confirming by NFC 17-102-2011 and UNE 21186 Standard, Non electronics based deivce shall emit electronmagnetic impulse in the form of a streamer intothe air microseconds earilier than naturally.(i) Lightning impulse current (10/350 µs) in 100 KA tested (ii) Serial no mentioned in Each Model of Air Terminal quality certificate. (iii) Material metal housing stainless steel 304. (iv) central rod dia 20 mm elect/magnetic shielding (v) can be qualified in compliance of CPRI (central power research institute). Govt of India for the Impluse current of (8/20 µs) in 40 KA with 5 poistive & 5 negative impluse (vi) Covering radius 107 meter in Level-IV Protection with 8 mtr mast. 54 Lightning Air Terminal Adaptor. Supply of highly insulated polyplatic adaptor to fix the lighnting ESE air terminal with the mat. The adaptor shall have suitable metal connector/ connecting point in such a way the top portion shall be electrically connected to the central final trip (elevated sharp tip) of the ESE air terminal and the bottom portion shall be connected to the down conductor. 55 MAST GI (supporting mast): supply of GI mast for mounting the terminal & adaptor with the ESE air terminal i compliance with IEC 62561-1.(i) GI mast length:- 8 Mtr (ii) GI pipe heavy duty, bottom 80mm dia, 3m, middle pipe dia 65mm, 2m (iii) standard: IS 1239 Part I): 2004 (iv) Base plate: GI Base plate size (250x250x5mm) (v) both the GI mast to be connected with the help of 2 flanges with 4 GI plated nut bolt with washers. The base plate size in (300x300x6mm) GI with requisite fitted with 4 hold the mast. (v) Necessary concrete foundation, earth work for holding the lightning conductor in position is deemed to be included in quoted unit rate. 56 Guy Wire Kit: Supply of Guy wire GI Nickel coated 4mm dia. Covered with white sleeve for extra protection and avoiding rusting. Length of the Guy wire is 6 mtr x 3 no = 18 mtr with accessories like:(i) Guy wire Nickel coated with white convered waterproof sleeve-18 metre(ii) U clips - 6 nos (iii) Pin type zebra anchor fastner-4 nos (iv) O hook- type fastner/ eye bolt fastener-3 nos (v) GI nut bolt 12mm dia of suitable lenth - Nos as per site requirement. 57 Lightning Strike Counter: minimum sensitivity of 250 A at 100 KA.(i) Display Model: digital display (non- resettable type) (ii) Display Range: 000000 to 999999 (iii) Detected Maximum discharge current : 350 A, 10/350 microsecond wave (measurd according to NFC standards per IEC 60060-2)(iv) Tested as per IEC-60060-2 (v) Degree of protection : IP 65 (vii) Operating Temperature (*C): 20+~85 (viii) Strike count display 6 digt (ix) Standard NFC17 102 (2011) Make- Saboo Sysyems Pvt Ltd/KMV/ABB/Axis India Note: Item No 4.34 to 4.39 (i) Lightning arrrestor & its components shall preferably be supplied by same manufacturer. The installation shall be carried out by rep of manufacturer. Testing of LA shall be done in presence of Engineer- in- charge. 58 Chemical Gel Earthing system: Supply for advance chemical Gel earthing system of 1 No. of UL certified 7 CPRI tested environment friendly ground enhancing compund. The copper bonded rod shall be 3 mtr long, 17.2mm diameter 254 microns copper bonded steel rod surrounded with 25 Kg each or more quantity of resistance lowering grounding minerals ROHS certified. Distance between the rod shall be length of the rod all as shown on drawings.(i) Tested as per IEC 62561-2 (ii) CPRI tested at 5 positive & 5 Negative impluse 25 KA (iii) Meets the requirments as per IS 3043, IEC 60964-5-54, UL 467 (iv) Standard- As per IS-3043 & IEEE80-2000, Test certificate from NABL lab. Make : Pragati Electrocorp (P) Ltd Gurgaon / DEHN / JEF Techno 59 Pit Chamber-Round value box supply of FRP heavy duty UV resistance, weather proof earth pit cover as per OEM recommendations complete all as specified and diected. 60 M&L for UPVC pipes of 40 mm size for DC wires, having pressure capacity of 10 kg including fiting viz joints bends, tees, etc complete all as specified and directed. 61 M&L for UPVC pipes of 25mm size for DC wires, having pressure capacity of 10 kg including fiiting viz, joints, bends, tees etc complete all as specified and directed . Note:-(i) Earth work shall be measured and paid under relevant item. 62 M&L for perforated hot dipped galvanized iron cable tray having cable tray for AC & DC cable routine (300 x 50 x 5mm and 450 x 50 x 5mm) thickness 1.5 mm galvanization and perforation not more than 17.5% includeding fittings viz joints, bends, tees, etc in convenient section of length complete all as specified and directed. 63 Supply, installation, testing and commissioning of Vacuum Circuit Breaker 630 Amps, having rupturing capacity 350 MVA, HT 11 KV, 3 phase 50 Hz, indoor type, totally enclosed metal clad constructed from Aluminium Zinc sheet steel of 2mm thickness for incomer as ICOG confirming to IEC-62271-200 complete with, overload and earth fault protection, ammeter, voltmeter complete as incomer circuit breaker all as specified and directed alongwith following technical specifications:-(i) 630 Amps rating. (ii) Horizontolly draw out type. (iii) Trip rod and have RoF type & Rack in Rack out motorised type. (iv) Motorised spring charging mechanism with integral spring charging handle for manual spring charge. (v) Panel separation with every department like VCB, Metering, cable chamber & Bus bar chamber. (vi) Cast resin current transformer 11 KV, 600-300/1+1A, core 1, class 0.5, 15VA wih metering and protection core including necessary control wiring & PT 11 KV, core-I class, 3 Pole, Core-II class-0.5, 50 VA burden OVF 1.9 for 30 Second for metering & protection backed by HT & LT MCBs. (vii) Line PT should be mounted on rear side (top or bottom) of the panel. 64 (viii) Accessories like local remote switch, breaker control through MCB, indicating lamp RYB, spring charging, DC supply healthy, breaker ON/OFF breaker in service/test, multi function meter with RS-485 port (EM-6400NG), Digital Ammeter and Volt Meter, (ix) Separate master trip relay and anti pumping relay. (x) Comprehensive numerical protection relay should have built in integrated mimic compatible IEC-61850 for non-directional O/C, E/F,U/V, O/V protection type having following additional facility:-(a) Trip circuit supervision. (b) Distribution recorder. (c) Event log with date and time. (d) Conformal coating for harsh environment. (e) suitable to operate on 24 Volt DC for auxillary and control supply. (f) Fully internal arc type (25 KA for 1 second) as per latest IEC:62271-200. (g) Vacuum bottles should be tested for 100 full short circuit operations. (h) Manual closing/tripping of CB with compartment door closed. (j) The panel shall be provided with power pack battery backup for not less than 10 minutes. 65 (k) The height of the HT section should atleast be of 1400mm for human safety during the internal arc creation. (l) Breaker shall be provided with 6NO+1NC contacts for each position in service and test, (m) Wireless thermal sensor will be provided in each bus & each cable termination per panel, alongwith Zig-b contactor and the data of the same should be display on HMI. (n) The VCB shall be SCADA compatible. (o) The VCB interrupter, breaker & panel alongwith relay should be of same make for better coordination and better SCADA compatibility. 66 Supply, installation, testing and commissioning of three phase, 4 wire Bi-Directional HT CT/PT Digital Energy Meter automatic grade as per relevent IS, 110-240 V, (66 KV/Ѵ3/110/Ѵ3) industrial application, Optical Port, RS 232/485 communication current rating Imax 2A -/1A, automation grade, accuracy class 0.2s, D3M024 type and suitable to install between 66 KV Sub Station (Commercial supply of PSPCL) in replacement of existing PSPCL energy meter and 750 KWp Solar power plant, display parameters like KWh, KVArh, KVAh, KW, kVA, Frequency, Power Factor, Current, import and export of energey complete all as specified and directed by Engr-in-Charge. Make : Secure, model : Premier 300 or its technno commercial equivalent.Note : The contractor shall liaise with PSPCL for testing & calibration of the meter. Cost of the same deemed to be incuded in quoted rates. 67 ROAD/PATH/CULVERT 68 M&L for providing and marking broken centre/ side lines/zebra Lines, dashes, arrows etc on road pavement and the like of any description and width with thermoplastic paint hot applied with machine confirming to BS-3265 and according to the specification laid down by IRC and MOST (Mininstry of Surface Transpost) specification 2001 (4th revision) complete all as specified and directed. 69 EXTERNAL WATER SUPPLY 70 Construction of brick masonary valve pit of size 1000x1000x1000mm (internal dimension) with and including MS sheet cover fabricated from 3 mm thick MS sheet and frame of angle iron 40 mm x 40 mm x 5 mm with fixing arrangement hinges and locking arrangement and painting two coats of synthetic enamel paint over a coat of red oxide primer on MS cover and frame including necessary excavation and earth work in any type of soil, returning, filling in approved soil, disposal of surplus soil to a distance not exceeding 50 metre, 150 mm thick PCC 1:4:8 type D-2 using 40 mm graded stone aggregate as in foundation, brick work using pulverised fuel ash lime bricks in cement mortar 1:6, 15 mm plastering in cement mortar 1:4 both internally and externally, 100 mm thick PCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in flooring complete all as specified and directed by Engr-in-Charge. 71 PVC HDPE rotational moulded 5000ltr capacity water storage tanks (Cylindrical vertical type with closed top) triple layered,fixed in position and making inlet and outlet water piping line connections complete all as specified. Note : Staging for PVC water tank shall be paid separately under respective item. 72 S&F Pumping sets, centrifugal monoblock, electric driven, single phase, 2HPhaving discharge capacity 3.2 LPS at 20 mtr head, suction x delivery size 50x40mm all as specified and directed by EIC. 73 Supply and fixing PVC air braided hose pipe 25mm dia. 74 M&L for provisioning of staging at 2 mtr height for PVC HDPE storage tank 5000ltr capacity. Note : S&F of PVC water tank of 5000 ltr capacity not included in this rate and shall be paid saparetly under respective item. 75 SEWAGE DISPOSAL WORKS 76 Supply and fixing ofLLDPE septic tank designed to carry sewage and sullage, water including excavation in anytype of soil, PCC 1:4:8, PVC Pipe from last manhole to septic tank, vent shaft, vent cowl and misc connection like PVC Tee, PVC bend etc. complete for PWTS-STBF-160-01 (1600 Lts Capacity) (Make - Sintex) 77 Soakage wells exc, in ordinary Soil, Foundation in PCC 1:3:6, wells of Honey combed and solid in M-25 Concrete, including intercepting chamber, screen chamber Brick work in CM, RCC cover slab in M-25/ RR masonry / Filling with brick bats, complete of size 1.8 M dia X 3.0M deep. (CEJZ/STD-301/90 SHEET No 1/4to 4/4) 78 EXTERNAL ELECTRIC SUPPLY 79 Supply, installation, testing and commissioning of 11 KV, 630 Amp, 50 Hz, SF6 gas insulated, 21 KA/3 Sec 3 way Ring Main Unit of outdoor type, motor operated, extensible with 01 No. VCB 630 Amps as incommer and 02 Nos LBS as outgoing cable termination from front (Internal arc classification AFLR 21KA/1 Sec with bottom exhaust both for tank and cable box as per IEC:62271-200), enclosed in welded stainless tank having IP-67 degree of protection, leak rate of SF-6 gass less than 0.1% and tested as per IEC:62271-200, ring core type protection CT, line side isolator alongwith following technical specification:-(a) Electrical specification. (i) Nominal system voltage - 11 KV. (ii) Voltage variation on supply side - + 10 (iii) Corresponding higher system voltage - 12 KV. (iv) Transient condition - (-)20% or 10% combined variation of voltage and frequency. (v) Lightening impulse withstand voltage upto 75kVp. (vi) one minute dry/wet power frequency withstand voltage primiary - 28 KV. 80 (vii) Rated dynamic withstand current - 52.5 KA. (viii) No of short circuit operations at rated short circuit current of 21 KA for breaker - 50 Nos.(b) General specifications. All live parts, bus bars, shall be preferably be enclosed in non megnetic and non ferrite grade stainless steel tank grade SS-304 of minimum 2.5 thickness. The RMU shall be tested for internal arc test of 21 KA/1 Sec AFLR with bottom exhaust for safety of personnel for both tank as well as cable compartment as per IEC:62271-200. The outdoor enclosure shall have IP-55 protection for complete switchgears with top opening canopy & dedicated IP-55 cable compartment. The protection relay shall be for 3 o/c + 1 E/F (IDMT Type) self powered numerical protection relay with low and high set of over current and earth fault, MODBUS communicating alongwith RS-485 Port. Internal Arc classification should be with bottom exhaust only. The RMU should be SCADA compatible and trouble free operation at the temperature 40 degree C & above. 81 (C) Insulated Bus connected unit comprising of the following :(i)Air insulated enclosure with necessary bus connection via bushing VTs from manufacturer and according to IS:3156. (ii) Sinle phase bus PT for metering - 11 KV/rt3/110V/rt3, 50 VA, class 0.5. (iii)Auxillary transformer - 11 KV/230V AC, 1 KVA. (iv) Multifunction Meter - EM6400 NG class 0.5 for incomer(d) The following accessories should be included in deemed rate:(i) Antireflex operating hadle. (ii) Battery 24 V DC, 12 Ah. (iii) Battery charger 24V DC. (iv) Manometer with remote contact.Note : RMU should be manuctured, inspected by rep of the Acceptung Officer and invoiced from the OEM factory. 82 Supply, installation, testing and commissioning of Vacuum Circuit Breaker 630 Amps, having rupturing capacity 350 MVA, HT 11 KV, 3 phase 50 Hz, indoor type, totally enclosed metal clad constructed from Aluminium Zinc sheet steel of 2mm thickness for incomer as ICOG confirming to IEC-62271-200 complete with, overload and earth fault protection, ammeter, voltmeter complete as incomer circuit breaker all as specified and directed alongwith following technical specification:-(i) 630 Amps rating. (ii) Horizontolly draw out type. (iii) Trip road and have RoF type & Rack in Rack out motorised type. (iv) Motorised spring charging mechanism with integral spring charging hangle for manual spring charge. (v) Panel separation with every department like VCB, Metering, cable chamber & Bus bar chamber. 83 (vi) Cast resin current transformer 11 KV, 600-300/1+1A, core 1, class 0.5, 15VA wih metering and protection core including necessary control wiring & PT 11 KV, core-I class, 3 Pole, Core-II clause-0.5, 50 VA burden OVF 1.9 for 30 Second for metering & protection backed by HT & LT MCBs. (vii) Line PT should be mounted on rear side (top or bottom) of the panel. (viii) Accessories like local remote switch, breaker control through MCB, indicating lamp RYB, spring charging, DC supply healthy, breaker ON/OFF breaker in service/test, multi function meter with RS-485 port (EM-6400NG), Digital Ammeter and Volt Meter, (ix) Seprate master trip relay and anti pumping relay. (x) Comprehensive numerical protection relay should have built in integrated mimic compatible IEC-61850 for non-directional O/C, E/F,U/V, O/V protection type having following additional facility:-(a) Trip circuit supervision. (b) Distribution recorder. (c) Event log with date and time. 84 (c) Event log with date and time. (d) Conformal coating for harsh environment. (e) suitable to operate on 24 Volt DC for auxillary and control supply. (f) Fully internal arc type typed (25 KA for 1 second) as per latest IEC:62271-200. (g) Vocuum bottles should be tested for 100 full short circuit operations. (h) Mannal closing/tripping of CB with compartment door closed. (j) The panel shall be provided with power pack batter backup for not less than 10 minutes. (k) The height of the HT section should atleast be of 1400mm for human safety during the internal arc creation. (l) Breaker shall be provided with 6NO+1NC contacts for each position in service and test, (m) Wireless thermal sensor will be provided in each bus & each cable termination per panel, alongwith Zig-b contractor and the data of the same should be display on HMI. (n) The VCB shall be SCADA compatible. (o) The VCB interrupter, breaker & panel alongwith relay should be of same make for better coordination and better SCADA compatibility. 85 (E) Indicating lamps LED type(i) Breaker ON Red clolour - 01 No(ii) Breaker OFF Green Colour - 01 No(iii) Auto Trip indication amber colour- 01 No(iv) Trip circuit heathly clear - 01 No(v) Spring charged blue colour - 01 No(vi) RYB indication - 03 Nos(F) Accessories (i) Trip Neutral Close Switch - 01 No(ii) Space heater with thermostat - 01 No(iii) Local Remote Switch - 01 No(iv) 3 Pin Plug Connector - 01 No(v) MCB AC & DC - 02 Nos(G) Relays(i) Numerical relay 50/51/50N/51N, non communicable, non draw out type - 01 No(ii) Master trip relay - 01 No(iii) Auxillary relay for transformer (3 elecments) - 02 Nos 86 M & Lfor Boring of holes under roof, pavement, hardstanding by trenchless technology using ultrasound technique and necessary machine including HDPE pipe of 75mm dia suitable for 0.4mpa working pressure all as pecified and directed. 87 Supply, fixing, testing and commissioning of junction box incl AI bus bar with MCB SP 6A, 10 KA, C curve & PVC cable 2.5 sqmm 2 core weather proof, aluminium conductor upto 7.5 mtr length for connection for single or 3 incoming cable & for outgoing and single phase connection of secuirty light fitting from junction box , PVC conduit pipe upto junction box , enclosed in tehermo plastic enclouser,shock proof , weather , dust , rust & water proof internally embedded gasket with provision for cable entry of size 300x200x125mm alongwith MS clamps, through and incl suitable gland all as specified. 88 Supply, install , testing and commissioning of LT feeder pillar distribution panel board CPRI approved, outdoor type, weather/vermin proof, mae out of 3.15 mmm thick CRCA sheet duly powder coated of suitable size and medium channel 75mm base mounting frame double door factory assembled cubicle pattern modular and compartmentalized construction, floor mounted free standing type 3 phase and netural 200 Amps current carrying capacity aluminium bus bar with epoxy insulated coating with colour code and insulated support, cable galleries inter connecting busbar connection/linkage complete and conforming to IS : 8623 and IP 54 class of protection as per IS ; 2147 complete with the following accessories and suitable for housing one incoming MCCB and outgoing MCCBs of capacity as below completed and mounting the panel board on ground with PCC (1:3:6) , bedding upto a height 30cm above ground level complete all as specified and directed (OR CH/DH) 89 (a) Aluminium busbar 200 Amp for 3 phase & netural -1 Set. (b) MCCB 4 pole 100 Amps 25 KA at 415 V -1 No (incomig)(c) MCB TPN 32 amps, 10 KA , C curve -Nos (outgoing)-02 , spare-01). (d) MCB SP 16 A , 10KA , C Curve-2 Nos (for street lights). (e) Digital Voltmeter with selector switch 0 to 500 volt- 1 No. (f) Digital Ammeter with selector switch and CTs 0 to 500 Amps-01 No. (g) Timer switch with set of contactors - 1 No. (h) LED type indicator lamps (R 90 MANNING & OPERATION (M&O) UNDER PH-II 91 First year manning and operation of 750KWp Solar Power plant round the clock by providing following staff on all days including Sunday and Holiday for trouble free functioning of the installation at Adampur to ensure maximum solar energy is fed to grid including following:-(i) Trouble free operation of the solar power plant. (ii) Monitor the performance of the solar plant by data logging. (iii) Monthly report preperation and reporting to customer on performance of power plant. (iv) Maintainance of module- periodic cleaning of module through water. (v) Schedule maintainance of invertor. (vi) Frequent testing of plant equipment by walk down checks to internal condition of equipments such as module perfomance, inverter test monitoring, system testing etc. (vii) Careful logging of operation data and periodically processing it to determine abnormal slowly detoriating conditions. (viii) Attendto emergency break down/repair of the component without any delay. (ix) Careful control and supervision of operation conditions (wide and rapid variation in voltage and frequency conditions do contribute to increase maintainance). (x) Regulate routine maintainance work such as keeping equipment clean, cleaning of solar PV Module, proper maintainance of inverters, maintainance of LT/HT cable lugs, Panels, MCCBs, Joints, 92 Transformer, VCBs etc of any type/size and capacity. (xi) Spare parts maintainance including replacement of defective parts. (xii) Securing all equipments/materials against damage/theft etc. (xiii) Keeping complete area neat & clean through spray chemicals and cleaning of grass at regular interval of time. (xiv) Servicing and maintainance of SCADA System and taking printout of all the data from SCADA once daily. (xv) The thermal imaging of PV Panels should be taken for checking its healthiness once as directed by the Engg-in-Charge. (xvi) The shutdown time of interval should be monitored and recorded. Min staff (s) to be employed (a)Sopervisor : 01 No in one shift of 8 Hrs ( 0800 Hrs to 1600 Hrs) having diploma in electrical Engg and having good knowledge of SCADA system.(b) Electrician (ITI Electrical) - 01 No in one shift (0800 Hrs to 1600 Hrs) (c) Helper (Min 10th pass) : 01 No in three Shifts. (0600 Hrs to 1400 Hrs, 1400 Hrs to 2200 Hrs, and 2200 Hrs to 600 Hrs) 93 MANNING & OPERATION (M&O) UNDER PH-III 94 Second year manning and operation of 750KWp Solar Power plant round the clock by providing following staff on all days including Sunday and Holiday for trouble free functioning of the installation at Adampur to ensure maximum solar energy is fed to grid including following(i) Trouble free operation of the solar power plant. (ii) Monitor the performance of the solar plant by data logging. (iii) Monthly report preperation and reporting to customer on performance of power plant. (iv) Maintainance of module- periodic cleaning of module through water. (v) Schedule maintainance of invertor. (vi) Frequent testing of plant equipment by walk down checks to internal condition of equipments such as module perfomance, inverter test monitoring, system testing etc. (vii) Careful logging of operation data and periodically processing it to determine abnormal slowly detoriating conditions. (viii) Attendto emergency break down/repair of the component without any delay. (ix) Careful control and supervision of operation conditions (wide and rapid variation in voltage and frequency conditions do contribute to increase maintainance). (x) Regulate routine maintainance work such as keeping equipment clean, cleaning of solar PV Module, proper maintainance of inverters, maintainance of LT/HT cable lugs, Panels, MCCBs, Joints, 95 Transformer, VCBs etc of any type/size and capacity. (xi) Spare parts maintainance including replacement of defective parts. (xii) Securing all equipments/materials against damage/theft etc. (xiii) Keeping complete area neat & clean through spray chemicals and cleaning of grass at regular interval of time. (xiv) Servicing and maintainance of SCADA System and taking printout of all the data from SCADA once daily. (xv) The thermal imaging of PV Panels should be taken for checking its healthiness once as directed by the Engg-in-Charge. (xvi) The shutdown time of interval should be monitored and recorded. Min staff (s) to be employed (a)Sopervisor : 01 No in one shift of 8 Hrs ( 0800 Hrs to 1600 Hrs) having diploma in electrical Engg and having good knowledge of SCADA system. (b) Electrician (ITI Electrical) - 01 No in one shift (0800 Hrs to 1600 Hrs) (c) Helper (Min 10th pass) : 01 No in three Shifts. (0600 Hrs to 1400 Hrs, 1400 Hrs to 2200 Hrs, and 2200 Hrs to 600 Hrs)
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 7
23.
Health and Family Welfare #9345222 Technical Bid
Tender For Supply Of Drugs/Surgical And Equipment, Medicine During The Year 2024-25- 1 Type c category equipments, furniture, implants and medicines 2 Autoclave Surgical drum SS-Size 15*12 approx 3 Autoclave Surgical drum SS-Size 9*9 approx 4 Autoclave Surgical drum SS-Size 11*9 approx 5 Autoclave Surgical drum SS-Size 11*5 approx 6 OT Trolly (Dressing) 7 Supra Pubic Trocar 12 No 8 Supra Pubic Trocar 8 No 9 Supra Pubic Trocar 14 No 10 Tooth Forcep & Non Tooth Forcep Midium Size 11 Suture Cutting (Micro) 12 Mayo Scissors (Carved) Midium 13 Nebular (Bone Cutter) 14 Sharp Scissors 9.0ml 15 Tissue Cutting Scissors Carved Midium 16 Mosquito artery big Size 17 Mosquito artery Medium artery 18 Gigli Saw vial 19 Bone Saw Big 20 Hegars Dilator set 21 Biopsy Gun 22 H.B Skin grafting handle 23 Bull dog 24 clamp 25 Suction Cannula disposable 26 O.T. Light double dome 27 Cautery Pin 28 Triway catheter No 20 29 Urinary Cathetor No 12, 30 Urinary Cathetor No 14 31 Urinary Cathetor No 10 32 K-90 Catheter 33 Tommy Syringe 34 Hperdomic Needle No 16 35 Hydrogen Peroxide (500ml) 36 Small Tooth 37 Non Tooth forcep 38 Bone Vax 39 Senetizer 40 Disposable Syrienge 2ml 41 Disposable Syrienge 5ml 42 Disposable Syrienge 10ml 43 Disposable Syrienge 20ml 44 Uro Bag 45 Adhesive Tape Roll 4 46 Paper Adhesive Roll PER Pack 47 Gloves No 6.5 48 Dressing Disposeble Gloves 49 Spinal Needle 50 Ven flow No 20 51 Suction Tube 52 Oxygen Key 53 Oxygen Flow Meter Set 54 Vicryl 3.0 Round body 55 Vicryl 2.0 ½ cr RB Needle 30mm 56 Vicryl 3.0 ½ cr RB Needle 22mm 57 Vicryl 3.0 ½ Cutting Needle 58 Vicryl 1 ½ cr RB Needle 36mm 59 Vicryl 1.0 ½ cr RB Needle 30mm 60 Ethilon 1. 0 ½ cutting Needle 36mm 61 Ethilon 2. 0 3/8cutting Needle 36mm 62 Ethilon 3. 0 3/8cutting Needle 36mm 63 Silk – 1.0 64 Silk – 2.0 65 Silk – 3.0 66 Hydrogen peroxide 6% 400ml 67 Butroclot solution 68 Drain sheet (Currugeted) 69 Sumag Ointment 70 Dis. Needle 16no, 71 K90 Katheter 72 3 way stop cock with extension line 73 Needle 24x1 ½ 74 Lignocain 4% vail 75 Endotrachial Tube 7.5cm 76 Endotrachial Tube 8.5cm 77 Poly Propylene 2.0 1/2 cr RB Needle 30mm 78 Surgical Cap 79 Chair S TYPE 80 Abdomans Spange 20 X20 81 Tailar Scisor 82 Feetal Doplar DIGITAL 83 Nebulization Machine 84 Giuco Meter 85 BP Instrument standmodal 86 BP Instrument Digital 87 Palse oximeter tabel Top 88 fogging Machine 89 Digital Tharma meter 90 Baby Tray 91 Autoclav drum 92 Gyser 20 LITER isi MARK 93 Wheel Chair 94 Digital Watch 95 O2 Flow Meter 96 Kideny Tray 8 97 Doctor Chair 98 Sizzer 8 99 Epigiotomy Sizzer 100 Hand Wash 500 ml 101 dispossable syrienge 50ml 102 dispossable syrienge 20ml 103 dispossable syrienge 10ml 104 dispossable syrienge 5ml 105 dispossable syrienge 3ml 106 dispossable syrienge 2ml 107 Follyes Cathetar 16 No 108 Endotrachial Tube 2cm 109 Endotrachial Tube 2.5cm 110 Endotrachial Tube 3cm 111 Endotrachial Tube 3.5cm 112 Endotrachial Tube 5cm 113 Endotrachial Tube 6cm 114 Endotrachial Tube 7cm 115 Endotrachial Tube 7.5cm 116 Endotrachial Tube 8.5cm 117 Endotrachial Tube 8cm 118 Air Pressure Line 119 O2 mask 120 NRBM Mask 121 Flatus Tube 122 Glucometer Strip 123 Albumin Strip 124 UTP Kit 125 Celispaid 126 Senitary Pad 127 Ambu Bag Adult 128 Ambu Bag pediatric 129 mettress 4 (6 x3) fom with cover 130 Baby Diper 131 Ventilator Tube 132 Pediatric dreep set 133 IV Stand SS 4 Wheel 134 Oxygen Key 135 Sterlizer Medium Size 136 Chair office 137 Steel Tray with Cover 138 Nebulization Mask 139 Refrigerator 180LIT 140 Strature with wheel 141 Lade Aprone 142 Nasalprobe Child 143 Nasalprobe Adult 144 Mayo sizzer 145 Fine tooth Forcep 146 tooth Forcep big 147 Step StoolMS 2 Step 148 Pattela Holding Forcep 149 Bone Cutter 150 Giggli Wire 151 T- Handel 152 Tubalring 153 Mucous Extractor 154 Caord clamp 155 Baby Tag 156 Romo Vac sizes of10, 12, and 14 FGbellow unit capacity is 800 ml.curved Needle Length is 175 cm. 157 Pules oximeter tabal Top 158 Weight Machine Adult 159 Enfusion Set 160 PPE Kit 161 Feeding Tube 5 no 162 Feeding Tube 6 no 163 Feeding Tube 7 no 164 Feeding Tube 8 no 165 P.M.O. Line 166 Adult Nosal Prong 167 Water Cooler 40 Litter 168 Urine polmale 169 Tuning fork (256) 170 Stop Watch 171 Percussion hammer 172 omce Table 173 Office Dustbin 174 LED Torch 175 Iron Almiraha 6 176 DigitalClock 177 FUJI PRINTER DRY IMAGING FILMOBX 10 DIGITAL X-RAY FILM 178 DISTAL REDIUS T,T OBLIQ PLATE (SIMPLE) 179 3.5 MMLOCKING CLEVICALPLATE ( 5 TO 8 HOLE ) 180 3.5/2.7 MMLOCKING CLEVICAL SUPERIALPLATE (5 TO 8 HOLE) 181 ADWANTEG SYRING 182 Illizarov Set 183 Modular Bipolar Set (1 Cese) 184 Blood Bank Refrigerator Technical specifications: Blood bank refrigerator1- Blood bank refrigerator – capacity 100 blood bags or more with two or more shelves.... 2- Inner chamber made of stainless steel, outer chamber made of powder coated steel sheet with high quality insulation material between the walls.3- Microprocessor based temperature controller with preset temperature 4 degreecentigrade plus minus 1 degree centigrade .and digital temperature display. 4- 50 htz 220-240 volts Ac power supply (single phase power supply in India). 5- Audio-visual alarm for low (less than 2 degree centigrade) and high (more than 8 degree centigrade) temperature.. 6- 7 day circular temperature chart recorder- in built.. 7- Air circulation fan. 8- Light bulb inside chamber. 9- Auto defrost mechanism or frost free, CFC free. 10- In built line voltage corrector 11- Vendor has to support the specifications with manufacturer’s brochure failing which offer may be rejected. Vendor has to demonstrate the equipment at BHEL General Hospital, Hyderabad within specified time limit, if asked for; failing which offer will be rejected. 185 Blood Celll Counter Impedance method for WBC, RBC and PLT counting Cyanide free reagent for hemoglobin test21 parameters: WBC, Lymph#, Mid#, Gran#, Lymph%, Mid%, Gran%, RBC, HGB, HCT, MCV, MCH, MCHC, RDW-CV, RDW-SD, PLT, MPV, PDW, PCT, P-LCR, P-LCC3 histograms for WBC, RBC and PLTPrediluted mode ≤20μL | Whole blood mode ≤9µL , 60 samples per hour10.4 inch TFT Touch ScreenChinese, English, Spanish, Portuguese, Russian, French, Bahasa, IndonesiaUp to 400,000 results including numeric and graphical information LAN Port supports HL7 protocol | Support bi-directional LIS4 USB ports (for external printer, software upgrade, barcodereader, external WIFI, keyboard and mouse), LAN port (1)Thermal recorder, 50 mm wide paper, various printout formats External printer optionalTemperature: 15°C~35°C | Humidity: 10%~90%Air pressure: 70kPa~106kPa(100V-240V)±10% through online UPS (rating 1 KVA)≤180VA | (50Hz/60Hz)±1Hz ,410(L) x 300(W) x 400(H) mm ; 20Kg 186 DefibrillatorTECHNICAL SPECIFICATION OF DEFIBRILLATORDESCRIPTION of Function• Defibrillator is required for reviving the heart functions by providing selected quantum ofelectrical shocks with facility for monitoring vital parameters.Operational Requirements• Defibrillator should be Bi- Phasic, light weight and latest model• Should monitor vital parameters and display them• Should print the ECG on thermal recorders.• Should work on Manual and Automated external defibrillation (AED) mode. Manualselection up to 270 J.• Should be capable of doing synchronized & asynchronized cardioversion• Can be operated from mains as well as battery• Should have defibrillator testing facilityTechnical Specifications• Should be a Low Energy Biphasic defibrillator monitor with Recorder, having capability toarrest allarrhythmia within a maximum energy of 360 Joules• Should monitor ECG through paddles, pads and monitoring electrodes and Defibrillatethrough pads and paddles.• Should have Automatic Lead switching to see patient ECG through paddles or leads• Should measure and compensate for chest impedance for a range of 25 to 150 ohms• Should have a built in 50mm strip printer/ thermal recorder• Should have charging time of less than 3 seconds for maximum energy. Charging indicatorshould be there.• Should have bright electroluminescent display for viewing messages and ECG waveform of4 seconds• Should have external & internal paddles with paddles contact indicator – for good paddlecontact. Single Adult and pediatric paddles should be available.• Should have event summary facility for recording and printing at least 250 events and 50waveforms.• Should be capable of printing Reports on Event summary, configuration, self test, batterycapacity etc• Should have facility for self test/check before usage and set up function• Should have SP02 and NIBP integrated facility• Should have user friendly color coded operationEnvironmental factors• The unit shall be capable of operating continuously in ambient temperature of 10 -500 C andrelative humidity of 15-90%• The unit shall be capable of being stored continuously in ambient temperature of 0 -500Cand relative humidity of 15-90%• Shall meet IEC-60601-1-2: 2001(Or Equivalent BIS) General Requirements of Safety forElectromagnetic Compatibility.Power Supply• Power input to be 220-240VAC, 50Hz. Power cable should be fitted with Indian plug andadapter.• Resettable overcurrent breaker shall be fitted for protection• Should have a Rechargeable Battery capable of usage for at least 90minutes or 30discharges. 187 Electrolyte Analyzer Method Sample Speed :-Multi-Biosensor TechnoloTechnology 60-120µlISE ≥ 80 tests / hour Printer Inner Thermal Printer Expand FunctionAmbient Conditions PowerPower Requirement RS232 & COM Connector, Computer and Barcode reader available0-40°C, Relative humidity ≤ 85% AC 80V ∼ 260V, 50-60Hz, ≤ 80WEarth Voltage <5V, Online UPS (230V)with isolated, transformers - 0.5 KVAParameters K+ Detection Range (mmol/L) 0.50 ∼ 20.00 Precision (CV)≤1.0% Resolution (mmol/L)0.01MeasureScope & Precision Na+ 15.0∼200.0 ≤1.0% 0.1 Cl- 15.0∼200.0 ≤1.0% 0.1 Ca+ 0.10∼200.0 ≤1.0% 0.01 pH 4.00∼9.00 ≤1.0% 0.01 188 Elisa Reader WasherSpecifications for Microplate (ELISA) Reader1. Should have minimum wavelength range of 400–750 nm and photometric range of 0.0–3.5 OD2. Should have linearity of ≤1.0% from 0.0–2.0 OD; ≤2.0% from 0.0–3.0 OD; accuracy of ≤1.0%or 0.010 from 0.000–3.000 OD at 490 nm; precision of 1.0% or 0.005 OD from 0.0–2.0 OD;1.5% from 2.0–3.0 OD and resolution of 0.001 OD3. Should have minimum 8 filter wheel capacity with 415, 450, 490, 595, 655, and 750 nm includedfilters4. Should have minimum 3 speed plate shaking with adjustable duration of 0–999 sec5. Read time should not be more than 6 sec at single wavelength or 10 sec at dual wavelengths6. Should have onboard graphical thermal printer and USB2 interface with PC or Mac datastations for data output7. Should be able to store data for over sixty assay protocols8. System should come with a comprehensive software package allowing colorimetric andturbidimetric analyses, as well as report analysis for raw data, absorbance, limit, matrix,normalization, and curve fit9. Software should have the functionality of flexible template creation for any microplate formatup to 1,536 wells10. Software should be either license free or license for minimum 5 systems should be providedSpecifications for Microplate washer Automatic washer compatible with strips and 96-well microplates that have flat-, U-, or Vbottom wells. Programmable needle positions (horizontal or vertical) to an accuracy of 0.1 mm for bottomwashing, crosswise aspiration, and overflow washing. Dispensing speed control A plate shaking option to help minimize bubbles and adherence of liquid to well sides. Wash bottle sensor to detect high waste liquid levels Up to 75 programmable washing sequences Easily removable 8- or 12-way manifolds Easily accessible manifold interior for maintenance Removable and autoclavable plate carrier An aerosol protection cover Integrated vacuum and dispensing pumps to ensure accurate and quiet washing and toeliminate the need for external pumps. Residual well volume should be < 6 µl Wash bottle volume should be 2000 ml Soak time in strip mode 0-9.9 sec and in plate mode 0-59 minutes. Should come with 8-way manifold and 12-way manifold should be quoted in optional. On-board software should be capable of storing up to 110 wash protocols. Operating temperature 15-40 °C. Dimensions (WxDxH) not more than 35x43x20 cm Both instruments should be of from same manufacturer 189 Semi-Automatic Biochemistry AnalyzersTechnical Specifications Human Machine Interface Touch Panel / Key Board / MouseLinear Measurement Range 0.000 to 3.000 Absorbance Units (A)Photometric Accuracy ±2% or 0.007 whichever is higher, from 0 to 2.0A, ±3% from 2.0A to 3.0ADrift <0.003A/hr.Optical Measurement Silicon Diode Filters Type of filterWave LengthHalf Bandwidth Filter SelectionFlow cell TypeFlow cell volumeSipping Volume Sipping Mode Cuvette Volume : Interference: 340,405, 450, 505, 546, 578, 630+2 Optional: ±2nm: By Stepper motor: Stainless steel body & Quartz Window: 32 μι: 300 to 1000 μι: Automatic by specially designed Peristaltic Pump: 500 μι Temperature of Cuvete/flow cell Block Method Temperature Light Source Warm up Time Display Printer Memory CPUBuilt in Incubator : By Peltier effect: 25°C, 30° C and 37° C: 6V/10W Tungsten Halogen lamp: 90 Sec.: 7 TFT Display 300 x 930: Built in 55 mm, stationary head graphical thermal printer: DDR, & DRAN 1 GB, Flash 256 MB: ARN Cortex A8720 MHz: 2 Place for coagulation reagent | 15 Place for coagulation Cuvette 5 Place for test tubes Storage Capacity 2000 Open tests with 30 QC results/test (Normal and Abnormal controls)200000 Patient results with patient ID and GraphAnalysis Mode 1 point, 2 point (Sample blank) | Fixed time | Kinetic | CoagulationConcentration calculation : By factor or by standard Blanking PortPower WattageVoltage Operating Position : Water, Reagent: 4 USB, LAN Rj45: 100 Watts: 110-240 Volts ±10%, 50-60 Hz: On horizontal, flat, rigid and vibration free surface Operating Conditions Temperature Relative Humidity : from +18° C to 35° C: up to 85% Storage Condition Temperature Relative Humidity EnclosureSize (cm) Weight : from 10° C to + 60° C: up to 85%: ABS Fire retardant: 30X38X13.5 (LxBxH): 7.0 Kgs. (Approx) 190 Suction MachineSpecificationsPortable suction unit: size 38x17x28.5cm, weight 5.1kgDescription (e.g.: model Vario A/C, manufacturer Medela)Technical specifications: SUCTION MACHINE with pump:- Power supply: 230-240V/50Hz- Vacuum capacity: 18 litres/mim- Maximum depression: -75kPa (-563mmHg)Vacuum is created by a plastic piston and cylinder system, with four vacuum-creatingmodules (QuatroFlex™ technology).The membrane vacuum regulator permits accurate vacuum settings.Double overflow-protection system (bottle and pump).Working temperature range: +5 to +40°C. 191 Microscope Technical SpecificationsSl Name TechnicalSpecsquotedby bidderBiddersDeviationif any3.1 Body :Binocular, sturdy, stable base body with focus adjustment controls3.2 Eye piece :Paired, high quality, (the image of the object as seen throughthe binocular eyepiece should be well defined centrally in at least 2/3field of view), achromatic, widefield, 10x without inbuilt pointer. Theeyepiece should be aplatanic and have a minimum field number of 18.Diopter adjustment must be present on one/ both eye pieces or on theeye piece tube3.3 Objective :Three objectives10x,40x,100x,10x and 40x objectives should have numerical apertures of 0.25 and 0.65respectively and should be of spring loaded type or otherwise.100x should have numerical aperture of 1.25 and should be of oilimmersion and spring loaded type. Suitable prominent marking should beprovided on 100x for easy identification.Unbreakable containers to be provided for storing the objectives. Allobjectives should be wide field, achromatic and parfocal.Making for the Objectives :Each objective should be engraved with thefollowing informations:-• Name of the manufacturer• Magnification and numerical aperture, for example, 10x/0.25• 100x objective should be engraved with the word ‘Oil’in changing from one objective to another or reintroducing the sameobjective by rotation of the nosepiece, the object at the center of thefield should not appear displaced by more than 0.02 mm in the objectplane in any direction.3.4 Nose piece:Revolving nose piece to accommodate a minimum of threeobjectives with click stops. It should be provided with ribbed grip for easyrotation mounted on a precision ball bearing mechanism for smooth andaccurate alignment. Extra ports if any should be fitted with dust proofmetallic/ebonite caps.3.5 Stage Uniformly horizontal, mechanical stage having dimensions oflength 140 mm (+/- 20mm) with fine vermier graduations (minimumreading accuracy of 0.1 mm). the stage should be provided with springloaded slide holder for exact positioning of specimen/ slide. It should bedesigned with convenient sub-stage vertical coaxial adjustment for slidemanipulation. The stage should have ball-bearing arrangement to allowsmooth travel in transverse directions i.e. 80 mm (+/-5mm) and front toback direction, 50mm (+/-5mm)3.6 Sub-stage condenser:Abbe-type condenser, numerical aparature (N.A.)1.25 focusable with rack and pinion arrangement incorporating anaspherical leps and an iris-diaphragm. The condenser should have a filterholder and removable/ swing in/ out blue filter (suitable for bright fieldMicroscopy).3.7 Sub-stage illuminator: 1.The system should have a build-in variable lightsource (Illuminator). This light source should have a 20 W, 6 V Halogenlamp. The circuitry for the light source should include a constant voltagesupply. The system should be provided with a step down transformer andan on-off switch and intensity control. The lamp should be provided witha lamp socket which has the facility for easy replacement of the bulb,2. Power Supplya. Voltage 220 V, 50 Hz ACb. Should have one on-off power switch, 3 core power cord with a 3 pointmale plug.3. The system should have an inbuilt protective/ safety device towithstand fluctuations of voltage from 140 V to 280 V4. A plano-concave mirror in fork mounting should be supplied whichwould be attachable to the base for field use. (where power is notavailable).5. The fuse for the halogen lamp should be easily accessible to theoperator6. The Illuminator should have a build-in field diaphragm for Kohlerillumination3.8 Eye piece tubes:Binocular eye piece tubes, inclined at 45 degrees,rotatable through an angle of 360 degrees, having inter-pupullarydistance range of 54-74 mm or wider, covering the above mentionedrange3.9 Focusing knob:Co-axial coarse and fine focusing knobs capable of smoothfine focusing movement over the full range of coarse travel. The finefocusing movement should have sensitivity of two microns or less (finer)over the entire coarse focusing stop safety arrangement should beprovided.3.10 General 1.All optical parts including objectives, eye pieces and prismsshould have anti-reflective coating which also gives anti-fungal property.2.All metallic parts should be corrosion-proof, acid-proof and stain-proof3.Working manual should be provided with each microscope4.A bottle of at least 25 ml immersion oil, a roll of lens tissue paper andlens cleaning solution (100 ml) should be provided with each microscope.5.One no.of anti static cleaning brush should be provided with eachMicroscope for cleaning purpose.6.Each Microscope should be supplied with Blue filters. The Blue filtershould be packed in the ox and not fixed on the Microscopes. 4 System Configuration Accessories, spares and consumablesSl Name TechnicalSpecsBiddersDeviationquotedby bidderif any4.1 System as specified-4.2 Each microscope should be supplied with spare parts as under:•100x oil immersion objective (as per the specifications given under B3) –one.•Halogen bulb, (6volts, 20w) – 6 Nos.•Fuses – 6 Nos.4.3 All consumables required for installation and standardization of system tobe given free of cost. 192 Truenat Machine 3. Equipment and site preparationAn essential step of the implementation process is the selection of instruments to fit theneeds of the testing algorithm, anticipated workload and intended setting of use theTruenat TB tests. Laboratories should select the appropriate number and models ofTruelab micro PCR Analyzers to match anticipated demand (see Table 4 for estimationof throughput). Note that the ability of a testing site to utilize all of the capacity ofa workstation may not be an important factor for selecting Truenat TB testing sites, especially considering that the Truenat TB test isdesigned to be placed at peripheral microscopycenters.All instruments must be documented to be “fit forpurpose” through testing with known positive and/or negative material prior to commencing testingof clinical specimens.Planning for service and maintenanceTruelab and Trueprep instruments require minimalpreventive maintenance as per the manufacturer.For an example of a preventive maintenance logthat shows routine daily and monthly activitiesas well as ad hoc activities to be conducted asnecessary, see Annex 4.The manufacturer offers warranty packages forequipment service and maintenance includingthrough its growing network of in-country serviceproviders. Annual warranties that providecomprehensive service and maintenance includingon-site visits are available through the Stop TBPartnerships Global Drug Facility (GDF); seethe GDF Diagnostics Catalog for more details.Countries planning to implement Truenat shouldinform the manufacturer in advance to allow themanufacturer to plan as needed for expansion ofits network of service providers.Site preparation and assessment of readinessAs part of the situational analysis, each of theselected testing sites will have been evaluatedfor suitability for conducting Truenat TB testingusing a standardized checklist (see Annex 6). Keyinfrastructure and operational considerations forsite preparation include:• Power: In-built batteries in both devices allow fortesting without power for up to 8 hours; deviceswill not allow for a cycle to start if battery poweris too low. Batteries are expected to last fiveyears. Note that power is still required to chargebatteries: recharging time is approximately 4hours for the micro PCR analyzers, 9 to 10 hoursfor the Trueprep device and 4 to 6 hours for themicro printer. Use of instruments while chargingis possible, when the electrical socket is wellgrounded. The devices are able to operatewithin the 100-240 voltage range; no additionalvoltage stabilization is required in settings withinstabilities or low voltage. Solar panels maybe a solution for settings without any access topower (see Box on specifications). Power mayalso be required to possibly cool the storageroom for test chips; as described below, chipsshould be stored at ≤30°C.Activities at a glance□ Select, procure, install and set-upequipment□ Verify the instruments are fit for purpose□ Arrange for preventive maintenanceand servicing□ Prepare site infrastructure for Truenatinstruments and testing□ Ensure a safe and functional testingsiteSuggested specifications of a solar panelas per the manufacturer:• Panel: 150 Watts. Dimensions (LxWxH):1490 x 665 x 35 mm• Battery: 12V 18Ah Lead Acid• Solar Charge Controller + DC to DCboost converter (12V to 170V, 100 Watts)Controller and converter available fromMolbio; panel, battery and installation tobe locally sourced. 193 Ice Lined RefrigeratorILR can maintain a temperature from +2°C to +8°C with as little as 8 hours of power supply in 24 hours 194 Audiometer Air conduction Audiometry (125-8000Hz) Bone conduction Audiometry 195 Bio Chemistry AnalyzerGeneral Information Machine TypeTest Speed Test Principle Test Method Calibration Type : Random access: Constant 200 tests/hour (Mono Reagent or Double Reagent): Colorimetric method, turbidimetry, Immuno turbidimetry: 1 Point End, 2 Point End, Fixed Time and Kinetics: Linear and Non Linear 1 Point Linear, 2 Point Linear, ExponentialLogi - 10g, 3P, 4P, Multi-point Linear, Spline, Line Graph Sample UnitReagent UnitReaction Unit Sample Tray Sample TubeSample Volume Sample ProbeSample Barcode Reagent TrayReagent VolumeReaction Tray Reaction Volume : 40 Sample Positions: Micro Cup & Test Tube & Blood Collection Tube (Ф 12 - 13) mm * (25 - 100) mm: 2 - 30µL, Step by 0.1 µL: Liquid surface detection, timely tracking for liquid volume Collision Protection: Sample barcode reader (Option): 40 Reagent Positions (40 for R1 or 40 for R2) 24 hours cooling system with paltier pad inside: 20 – 300 µL, Step by 1 µL: 44 reaction new pyrex cuvettes, perfect transmittance: 150µL - 330µL Mixing system Mixer : Paddle-type mixing, effective and reducing carryover Optical SystemOperating system Light Source Wave LengthAbsorbance Range ResolutionOperating System Report Printing Interface : Halogen Lamp: 340nm; 405nm; 450 nm; 505nm; 546nm; 578nm; 630nm; 700nm (4 more options): 0 – 4.0 Abs: 0.0001 Abs: Windows XP, Windows 7, Windows 8, Windows 10: 6 Formats Optional, Support Custom Formats: Pattern, TCP/IP network Interface Working Conditions Power Supply : AC 110/220V ± 10%, 50/60 Hz, 1000VAWater consumption : 8L/hour (maximum) Dimension Weight : 750mm * 550nm * 490mm (L*W*H): 70 kgs Power Supply 110/220V ± 10%, 50/60 Hz, 1000VA,Earthing voltage < 5V online ups (230V) with isolated transformer 2KVA 196 Blood Donor Couch Comfortable chair type with soft padding for cushioning and rexin cover.Seat, back rest and leg rest size designed for donor comfort.It should have step less electric remote controlled height adjustment approximately 58 – 60 cm.Adjustable arm rest for donor’s comfort and phlebotomist friendlyEasily tilted to head low position, electrically operatedComfortable working level for the operator. Lifting capacity - Approx 200 kg.4 Lockable castors for easy mobilityStorage Drawers for storing consummables & Blood Collection MonitorsUP/DOWN controlOPTIONS: 1.A paper roll holder can be fixed on the upper part of the chair. 2.Melodious musical Headphone can be integrated for patient relaxation while blood donation is in progress 197 BP Apparatus Digital 198 Cautery Machine SPECIFICATIONS FOR CAUTERY MACHINE(HIGH-END SURGICAL ELECTROCAUTERY WITH VESSEL SEALER)High-End Electro Surgical Unit with Vessel Sealer Unit should be comprised of:1. An integrated RF Electro Surgical Unit (For electrosurgical Cut & Coagulation modes for the optimum effectof HF surgery)2. Vessel Sealer (For sealing vessels & tissue structures, during open and laparoscopic surgeries).A) Electro Surgical Unit should be microprocessor controlled, US-FDA &/ European Certificate marked inaccordance with the medical devices directive (93/42/EEC) 4 Digit notified & Electro Surgical Unit shouldcomply with the requirement of the medical devices directive of class 1 equipment and electromagneticcompatibility.B) Electro Surgical Unit quoted should have a very strong Installation base- must be provided a minimum of 50installation base in India.C) Special bipolar mode for coagulation of vascular tissue (Vessel Sealing) up to 7 mm with Reusable/Disposable Hand Instrument for open as well laparoscopic surgeries & should have 510 K approval for 7 mmVessel.D) The system should have Monopolar Cut & Coagulation Mode, two Bipolar Modes with auto bipolar start &stop and Vessel fusion technology all integrated in one system. Should have around 8 Cutting Modes &around 8 Coagulation Modes.E) The equipment should be micro controller based & should adjust the power to get the desired surgical effecton the tissue. All settings should be controlled by the machine and according to the tissue deliver. Powershould be display on the screen with graph facility to show the deliver poweF) Should have Power and Voltage automatic regulation feature to prevent tissue damage and charring. Theoutput voltage should be regulated at various levels.G) The System should have LCD/ LED Backlight adjustment for good visibility in operating room, patient platemonitoring facility, audio-visual alarm, and deactivate output if contact between patient and patient plate isnot proper to eliminate the risk of patient burns.H) Should have optional facility of connecting reusable contact quality Monitoring Return Electrode Pediatric /Adult with 100% washable foot switches (for terminal cleaning & disinfection)- Monopolar & BiopolarI) The high End Electro Surgical Cautery Unit with Vessel fusion technology should be compatible with theintegration system of OR mainly O.E.M.’s like – Karl Storz, Olympus & De Vincy.J) The high-End Electro Surgical Cautery Unit with Vessel fusion technology should be supplied along withessential accessories from the same original equipment manufacturer, affidavit for the same has to besubmitted by the bidder, else bid will be rejected.1. Open and Laparoscopic Surgery Vessel seal instrument with cord. Reusable (which has certificate for theminimum shelf life of 50 applications and should be autoclavable- 01 each (Open & Lap) and ifDisposable 50 each (Open & Lap).2. Diathermy Pad/ Patients plate- adult/ pediatrics with patient plate cable if Reusable- 01 with a shelf lifeof minimum 50 applications and if disposable 50 pcs3. Monopolar two pedal footswitch 100% Washable/ Water resistant (for terminal disinfection) withminimum shelf-life of 1000 applications or 24 months from date of supply-1no.4. Bipolar one pedal footswitch 100% Washable/ Water resistant (for terminal disinfection) with minimumshelf-life of 1000 applications or 24 months from date of supply-1no.5. Monopolar electrosurgical pencil with different electrodes either Reusable 01 Unit with reusable 05electrodes of various shapes with a shelf life of minimum 50 applications or Disposable- 50 Units6. Nonstick Bipolar forceps Straight & bayonet each with bipolar cord for forcep either Resuable 01 Unitwith a shelf life of minimum 50 applications or Disposable- 50 Units7. Reusable universal adaptor for attaching several Laparoscopic hand instruments with a shelf life of aminimum of 50 applications-1no.8. Cart with Castors with unconditional replacement if break within 05 years from the date. 199 Centrifuge 12 Tube 200 DVT Pump Deep Vein Thrombosis (DVT PUMP)• Size: 6.5” L x 7.0” W x 12.8” H• Weight: 2.5kg• Pressure Settings:• Calf/Thigh sleeve: 30, 40 (default), 50, 60 mmHg ; +10/-5mmHg Foot sleeve: 120 mmHg ; +10/-5mmHg• Input Rating: AC 100V-240V 50/60 Hz, 0.2A-0.55A• Fuse Rating: 1A, 250V• Appliance Class: Class I, Type BF• Not AP or AGP type• Classification to FDA: Class II• Classification to CDSCO: Class B• Humidity: Operation 30% to 75 %• Storage & Transportation 30% to 75%• Air pressure: 4 – 16 kPA• Temperature: Operation 15° - 35° C• Storage & Transportation 5-60 degree C• Cycle Time: Inflation 12 seconds +/- 10%• Deflation: 48 seconds +/- 10% 201 Prolene Suture Size 2-0 202 Prolene Suture Size 1-0 203 Prolene Suture Size 3-0 204 Nylone Suture 2-0 205 Disposable Hemorrhoidal Circular Stapler 32mm with Two Circular Staggered Staple-Lines ( 2 Rows ) and Optimized Staple Formation Technique, Tissue Compression Indicator, Total 32 Staple Pins with Open Staple Leg Length of 3.5mm which can accommodates compressed tissue thickness from 0.75 to 1.5mm 206 Disposable Hemorrhoidal Circular Stapler 34mm with Two Circular Staggered Staple-Lines ( 2 Rows ) and Optimized Staple Formation Technique, Tissue Compression Indicator, Total 32 Staple Pins with Open Staple Leg Length of 3.5mm which can accommodates compressed tissue thickness from 0.75 to 1.5mm 207 Silk suture, USP 3-0, 70 cm, needle: 26*1*2 mm, reverse cutting, 3/8 circle. 208 Ethicon Ethilon Sutures USP 4-0, 3/8 Circle Reverse Cutting - NW3326 209 Nylone Suture 3.0 210 Botroclot Solution 211 Disp.LinearCutter 60 212 Disp.LinearCutter 80 213 Disp.LinearCutter 100 214 Disposable Curved Circular Stapler 29mm with Three Circular Staggered Staple-Lines ( 3 Rows ) and Optimized Staple Formation Technique, Tissue Compression Indicator, Open Staple Leg Length of 4.5mm which can accommodates compressed tissue thickness from 1.0- 2.5mm 215 Disposable Curved Circular Stapler 31mm with Three Circular Staggered Staple-Lines ( 3 Rows ) and Optimized Staple Formation Technique, Tissue Compression Indicator, Open Staple Leg Length of 4.5mm which can accommodates compressed tissue thickness from 1.0- 2.5mm 216 Acetylsalicylic Acid (Aspirin)*(Tablet 25 mg),Tablet [202209005] 217 Allopurinol(100mg),Tablet [110034] 218 Artemether + Lumefantrine(20mg+120mg),Tablet [110149] 219 Bisacodyl(5 mg),Suppository [110294] 220 Boro-Spirit Ear Drops-(0.183 gm Boric Acid in 2.08 ml of Alcohol 10 ml vial),Drop [202209052] 221 Charcoal Activated (Powder)(100 gm box/pouch),Oral Powder [110051] 222 Ciprofloxacin Eye Ointment 0.3% ( 3gm Tube) [4460001] 223 Clofazimine(Tablet 50 mg 4),Tablet [202209022] 224 Cloxacillin(500mg),Capsule [120092] 225 Cloxacillin(Capsule 125 mg),Capsule [202209020] 226 Codeine(Oral Solution 15 mg/5 ml 60 ml bottle),solution [202209080] 227 Diethylcarbamazine(Oral Liquid 120 mg/5 ml 100 ml bottel),Liquid [202209023] 228 Diloxanide Furoate(Tablet 500 mg),Tablet [202209024] 229 Diphenylhydantoin(Tab 30 mg 10x10),Tablet [202209013] 230 Dispersable Tablet Hydroxyurea (100 mg 10x10),Tablet [202209073] 231 Finofibrate(Tablet 40 mg),Tablet [202209041] 232 Fluphenazine 1 ml Amp(25 mg / ml),Injection [120354] 233 Glycopyrolate(Inj 0.2 mg/ ml 1 ml vial),Injection [202209001] 234 Gum Paint (Tannic Acid)(2% w/v 15 ml bottle),Bottle [202209046] 235 Halothane BP 250ml [4000001] 236 Hepatitis B Immunoglobulin(100 IU/Vial),Vial [110319] 237 Human Chorionic Gonadotropin(Injection 10000 IU vial of 1 ml injection),Injection [202209062] 238 Human Chorionic Gonadotropin(Injection 5000 IU vial of 2 ml injection),Injection [202209063] 239 Hydroxyethyl(6% Saline solution for infusion)(Starch 6%IP 500 ml Bottel),Infusion [202209083] 240 Imipramine(25 mg),Tablet [110360] 241 Insulin soluble Inj. - 40 IU/ml [4350097] 242 Ipratropium Bromide inhaler 20mcg per puff(200 metered dose container),Inhaler [1100376] 243 Isoxsuprine(10mg),Tablet [120174] 244 IV Human Immunoglobin 5% IV IG((5mg/100ml Each),Injection 100ml injection),Injection [202209067] 245 Ketamine hydrochloride(10mg/ml (10ml vial)),Injection [110003] 246 Levodopa (A) + Carbidopa (B)(Tablet 100 mg (A) + 10 mg (B) CR),Tablet [202209033] 247 Levodopa (A) + Carbidopa (B)(Tablet 100 mg (A) + 25 mg (B) CR),Tablet [202209034] 248 Levodopa (A) + Carbidopa (B)(Tablet 250 mg (A) + 25 mg (B)),Tablet [202209035] 249 Levosalbutamol(50mcg/dose 30 capsule in 6 pack with 1 dispecing device),Capsule [202209070] 250 Levosulbutamol(100 mcg 30 capsule in 6 pack with 1 dispecing device),Capsule [202209069] 251 Lithium Carbonate(300 mg),Tablet [110358] 252 Lorazepam2 mg / ml1 ml Vial [110369] 253 Losartan(10 mg Tablet),Tablet [202209057] 254 Medroxyprogesterone acetate(Injection 150 mg 1 ML / VIAL),Injection [202209064] 255 Methyldopa Tab. - 250mg [4710040] 256 Morphine(Injection 15 mg/ml 1 ml ampule),Injection [202209081] 257 Noraderanaline Bitartrate(2 Mg Base/2ml (2ml Amp)),Injection [700472] 258 Normal Saline(Nasal Drops: Sodium Chloride Drops 0.05% w/v 10 ml vial),Drop [202209053] 259 Ormeloxifene(Tablet 30 mg 10x10),Tablet [202209065] 260 Phenobarbitone(200 mg/ml),Injection [110060] 261 Pilocarpine Eye drops 2%(5ml),Vial [110327] 262 POMALIDOMIDE(Cap 2 mg),Capsule [202209031] 263 Pralidoxime (PAM) Inj(25 mg/ml),Injection [4350085] 264 Premix Insulin(30:70 Injection (Regular: NPH)2 vial of 100 ml),Injection [202209066] 265 Promethazine(Injection 10 mg/ml 2ml vial),Injection [202209002] 266 Protamine(Injection 50 mg/5 ml 5 ml vial),Injection [202209044] 267 Pyridoxine Tab 10mg [4710380] 268 Sodium Aminosalicylate Granules(10 gm Bottel of 100 gm),Powder [202209028] 269 Sucralfate (20 mg Tablet 10 x 10),Tablet [202209058] 270 Surfactant Suspension(Inj 25 mg/ml),Injection [202209077] 271 Tab Mebeverine(Tab 200 mg 10 x 15),Tablet [202209056] 272 Tamoxifen tab.(10 mg),Tablet [4710305] 273 TOPOTECAN(Inj 4 mg 4 ml vial),Injection [202209032] 274 Verapamil(Injection 5 mg/2 ml 2 ml vial),Injection [202209045] 275 Alpha-Beta Arteether Inj 75 mg / 2 ml [700153] 276 Ampicilline 125mg/30ml Syrup [987655] 277 Antacid Chewable Tablet containing Aluminum hydroxide equivalent to dried gel 250mg+ Magnesium hydroxide 250mg+ Simethicone 50mg USP [4710419] 278 Benzyl benzoate emulsion( emulsion),Emulsion [4220001] 279 Calcium Syp 100ML Syrup (240mg/5 ml) [987642] 280 Cefpodoxime200 mg + Ofloxacine 200mg Tab.(200+200),Tablet [120980] 281 Cetrimide + Choline Salicylate Gel for oral ulcer 15ml Tube [4760001] 282 Cetrimide Cream BP(0.1% w/w),Tube [4760003] 283 Chloramphenicol 0.5%(5ml),Eye Drop [120073] 284 Tab Ciprofloxacin 250 + Tinidazole 500 mg 285 Tab Ciprofloxacin 500 + Tinidazole 600 mg 286 Chlorhexidine 0.2% Mouth Gargle(100 ml),solution [4630028] 287 Clobetasol 0.05% + Gentamicin 0.1% Cream 10 gm(10 gm tube),Cream [120082] 288 Cyproheptadine HCL + Tricholine Citrate(2mg + 275 mg / 5 ml (100ml Bottle)),Syrup [120098] 289 Dicyclomine Syrup [987647] 290 Digestive Drop ( Digestive Enzyme And Multivitamin with L Lysine )( 15 ml),Drop [987868] 291 Domperidone +Ranitidine 150mg Tab [987691] 292 Doxylamine Succinate + Pyridoxine(10mg+10mg),Tablet [120117] 293 Gentamicin Inj. - 40 Mg/Ml, 2ml AMP [987917] 294 Insulin Human Mixtard inj. - 30:70( ),Injection Solution for [4350096] 295 Ipratropium Bromide Powder for inhalation 250mcg/ml [4330004] 296 Ketoconazole Tab [4710123] 297 Lignocaine Hydrochloride Topical Solution USP(2%),Vial [4790014] 298 Magnesium Sulphate Powder(400gm),Powder [20201043] 299 Nepafenac ophthalmic(Suspension 0.1%),Eye Drop [140099] 300 Nepafenac(1mg/ml),Eye Drop [120685] 301 Nifedipine (Sublingual)(10 mg),Capsule [120548] 302 Oseltamivir H1 N1 Antiviral syp 75 mg [700120] 303 Paracetamol + Chlorphenaramine+ Phenylephrine(250 mg + 2.5 mg + 10 mg),Tablet [120560] 304 Paracetamol + Phenylephrine + Chlorpheniramine Maleate (125mg+2.5 mg+1mg) /ml(15 ml Bottle with Dropper),Drop [120561] 305 Paracetamol 100 mg/ml, 150 ml Drop(150 ml),Consumable [987903] 306 Paracetamol 75 mg/ml(10 ml Inj),Injection [987904] 307 paracetamol drop(100 mg/ml),Drop [4700041] 308 Pentoprozole 40mg +Domperidone 10mg Tab [987675] 309 Peptonised Iron 176.5 mg(Equivalent to 30 mg of Elemental Iron,Protein (as Peptone) 100 mg,Folic Acid 200 mcg, Vitamin B12 2.5 mcg 100ml),Bottle [20200910] 310 Piroxicam(ointment),Ointment [10000] 311 Prednisolone(10 mg/ml),Eye Drop [120259] 312 Roxithromycin 150mg Tablet [987689] 313 Sodium Chloride (Ophthalmic) 5%(10 ml),Eye Drop [120596] 314 Sodium Hyaluronate (Intraocular)(10 mg /ml 2ml),Injection [120597] 315 Syp. Cefodroxil 125mg/30mlSyrup [987657] 316 syrup cefpodoxime(50 mg),Syrup [700426] 317 Visco Gel for eye department 318 BSS Solution For Opthalmic Use 319 Lignocaine 4% heavy 320 Tetanus Toxide inj 5ml( ),Injection Solution for [4350104] 321 TetracyclineEye Ointment 1% 5 gm [120603] 322 Flurbiprofen Sodium 0.03%(5 ml),Eye Drop [120492]
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 4
Madhya Pradesh View Result →
24.
Drinking Water Supply and Sanitation #9328569 Technical Bid
New Raw water Head Works at Pullagoundaenpatty in Komarapalayam Municipality.; 1 The rates for earth work excavation and refilling for pipe line works having bed width of 1.25m and below on linear measurement basis - Earth work rate for other than loose soil/m PVC/HDPE/GRP + Refilling the trenches with excavated earth (other than sand) in layers and watering, ramming and consolidation as per standard specification etc complete and as directed by Engineer in charge. 2 250mm Dia DI pipe 3 400mm Dia DI pipe 4 500mm Dia DI pipe K7 5 Earth work excavation and depositing on bank within an initial lead of 10 m and following lift and classification of soils.Hard stiff caly, stiff black cotton soil hard red earth, shales, murrams, gravel stoney eatch and earth mixed with small sized boulders. 6 Ist depth of 2m(For pump house) 7 Earth work excavation complying with relevant clauses in soft disintegrated rock, laterite, soft rock (or) kankar not requireiung balsting 8 Earthwork Excavation in loose soil 9 Leading Channel 10 Ist depth of 2m 11 Pump Room 12 Ist depth of 2m 13 Earth work excavation complying with relevant clauses in DMR not Requiring Blasting 14 Ist depth of 2m 15 Earth work excavation complying with relevant clauses in DMRRequiring Blastingmeasured in solid II nd depth of 1m 2-3m depth 16 2-3m Depth 17 Earth work excavation inHard rock rock requiring blasting for well cum pump house 18 2m-3m depth 19 3m-4m depth 20 4m-5m Depth 21 5m-6m depth 22 6m-7m Depth 23 7m-8m Depth 24 8m-9m Depth 25 9m-10m Depth 26 10m-11m Depth 27 11m-12m Depth 28 Removing hard rock by blasting and stacking 29 IInd depth of 2m (2m to 4m) 30 III rd depth of 1m (4M to 6m) 31 IV th depth of 1m (6m to 8M) 32 Supplying and filling in foundation andbasement with filling n layers of not more than 15cm.thick well rammed watered and compacted -1m3 etc., complete complying with standard specification. 33 Plain Cement Concrete 1:4:8 using 40mm size HBG stone for levelling course of foundation including mixing, placing, ramming, curing and finishing etc. complete 34 Centering for soffits of RCC members or plane surface including shuttering, strutting to the centering and providing supports etc. complete for the following members using MS sheets of size 90x60cm and BG 10 gauge stiffened with welded M.S. angles of size 25x25x3mm laid over silver oak (country wood) joists of size 10 x 6.5 cm spaced at about 90mm c/c and casurina props of 10 to 13 cm dia (spaced at 75cm C/C) for various heights and as directed by the Officers. The centering should beremoved after the specified striping time of the concrete as per IS-456/1978. 35 Plane Surface 36 Base slab 37 0-3.30 m above Bottom Level 38 3.3-4.30 m above Bottom Level 39 4.30-5.30 m above Bottom Level 40 8.30-9.30 m aboveBottom Level 41 11.30-12.30 m aboveBottom Level 42 Square Column 43 0-3.30 m above GL 44 3.30 m-4.30 m 45 4.30 m-5.30 m 46 5.30 m-6.30 m 47 6.30-7.30 m 48 7.30-8.30 m 49 8.30-9.30 m 50 9.30-10.30 m 51 10.30-11.30 m 52 11.30m-12.30m 53 12.30m-13.30m 54 Providing and laying in position Standardised Concrete Mix M-20 Grade in accordance with IS 456 - 2000 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement contenet of 325Kg/ cum and maximum water cement ratio of 0.55 including admixture (Plasticiser / super plasticiser) in recommended proportions as per IS 9103 to accelerate, related setting of concrete, improve workability without imparing strength and durability with about (5.0cum), 7730Kg of 20mm machine crushed stone jelly and with about (3.3 cum), 5156kg of 10 - 12mm machine crushed stone jelly and with about (4.79cum) 7670 kg of sand, but excluding cost of reinforcement grill and fabricating charges centering and shuttering but including laying, vibrating with mechanical vibrators, finishing, curing, etc and providing fixtures like fan clamps in the RCC floor / roof slabs wherever necessary without claiming extra cost etc., complete complying with standard specification and as directed by the departmental officers - The Coarse and Fine aggregates to be used should comply with the requiremnents of IS staandards. (No separate payment will be made by the Department for the excess usage of materials) 55 Up to Basement 56 Providing and laying in position Standardised Concrete Mix M-30 Grade in accordance with IS 456 - 2000 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement contenet of 400Kg/ cum and maximum water cement ratio of 0.45 including admixture (Plasticiser / super plasticiser) in recommended proportions as per IS 9103 to accelerate, related setting of concrete, improve workability without imparing strength and durability with about (5.0cum), 7730Kg of 20mm machine crushed stone jelly and with about (3.3 cum), 5156kg of 10 - 12mm machine crushed stone jelly and with about (4.79cum) 7670 kg of Crushed Stone sand (M- Sand) but excluding cost of reinforcement grill and fabricating charges centering and shuttering but including laying, vibrating with mechanical vibrators, finishing, curing, etc and providing fixtures like fan clamps in the RCC floor / roof slabs wherever necessary without claiming extra cost etc., complete complying with standard specification and as directed by the departmental officers - The Coarse and Fine aggregates to be used should comply with the requiremnents of IS standards. 57 Below GL 58 Below G.L . upto 1.50 m depth 59 Below G.Lfrom 1.50 to 4.50 m depth 60 Below G.L beyond 4.50 m -9m 61 Below G.L beyond 9.0 m -13.5m 62 Above GL 63 Above GL upto 4.50 m height 64 Above GL 4.50 m to 7.32m height 65 Above GL upto 7.32 m to 10.98m height 66 Above GL upto 10.98 m to 14.64m height 67 Suppling and fabricating and placing in position MS(or) R.T.S. bar for reinforcement to all RCC works as per the design given including cost ofsteel and binding wire also in all floors as per standard specification.TNBP-spl 68 Supplying and Delivery of the following Ductile Iron Socket/Spigot pipes and specials K-7 of best approved quality conforming to ISS including cost of all materials, labour, transportation etc., complete complying with standard specification. 69 250mm Dia DI pipe K7 70 400mm Dia DI pipe K7 71 500mm Dia DI pipe K7 72 Refilling as per IS specifications and as directed by the engineers for the following sizes in metres,as per drawing. 73 250mm Dia DI pipe K7 74 400mm Dia DI pipe K7 75 500mm Dia DI pipe K7 76 Supply & delivery of following sizes of DUCTILE IRON SOCKET/SPIGOT PIPES FOR CLASSK7 SPECIALSAS PER IS 9523/2000. 77 250mm D.I. 90 Degree Bend (46 Kg / Nos), 250mm D.I. 45 Degree Bend (36 Kg / Nos), 250mm D.I. 22.5 Degree Bend (31 Kg / Nos) 78 400mm D.I. 90 Degree Bend (113 Kg / Nos), 400mm D.I. 45 Degree Bend (82 Kg / Nos), 400mm D.I. 22.5 Degree Bend (67 Kg / Nos), 500mm D.I. 90 Degree Bend (187 Kg / Nos), 500mm D.I. 45 Degree Bend (135 Kg / Nos), 500mm D.I. 22.5 Degree Bend (107 Kg / Nos). 79 Loweringpipes and specials to trench and layingtopropergradeandalignment andas directed by the Officers. 80 250mm Dia DI pipe 81 400mm Dia DI pipe 82 500 mm Dia DI pipe 83 Jointing the C.I/ D.I - S/S pipes and specials with molten lead and Yarn including caulking the joints. (Including cost of jointing materials) 84 250mm Dia DI pipe 85 400mm Dia DI pipe 86 500 mm Dia DI pipe 87 Cutting C.I./D.I Pipes true to axis and filing smoothly and finishing the ends complete. 88 250mm Dia DI pipe 89 400mm Dia DI pipe 90 500mm Dia DI pipe 91 Barricading work (Where, there is less traffic areas and broader roads etc.) for laying of pipe line using casurina poles at 1.50m center to center (8cm to 10cm dia and 1.80m height) vertical with orizontal poles in three rows including painting the vertical poles in the road facing sides with ready mix paint, tying the vertical and horizontal poles with coir rope including fixing charges and fixing 75mm dia reflectors including earth work xcavation for fixing vertical posts and finally removing and stacking the aterials safely for further use etc., complete and as directed by Officers. 92 Barricading work (Where the lines are in narrow width of municipality area, busy streets like Market, Bus stand and in the Highways etc.) for laying of pipe line sing casurina poles at 1.50m center to center (8cm to 10cm dia. and 1.80m height) vertical with horizontal poles in two rows, painting the vertical poles in the road facing sides with ready mix paint, tying the vertical and horizontal poles with coir rope including supplying, delivery and fixing of GI sheet (0.90m x 0.8mm thick) in the horizontal poles and fixing 75mm dia. reflectors including earth work excavation for fixing vertical posts and finally removing and stacking the materials safely for further use etc., complete and as irected by Officers. 93 Testing of pipes for water supply with hydraulic testing equipment by filling with water (including cost of water @ Rs. 60/KL) and testing to recommended pressure in convenient stretches and attending the bursts if any occured during the test, excluding the cost of pipes but including other incidential and operational charges etc., complete for the following diametres of pipes. 94 250mm Dia DI pipe 95 400mm Dia DI pipe 96 500mm Dia DI pipe 97 Disposal of surplus earth including loading, conveyancewithin a distanceof5 km and spreading as directedbythe Engineer in charge. 98 Supply, Delivery and fixingof DI D/F Gate valves (Soft Seated) resilient seated soft sealing gate valves (sluice valves) with body bonnet of ductile cast iron of grade GGG40 or equivalent grade, wedge fully rubber lined with EPDM, replaceable spindle nut, without gland packing and with 3 O-Ring protection on the shaft and seals of NBR and the valves should be of vaccum tight and 100% leakproof with face to face dimentions as CI D/F SLUICE VALVE WITH CAP/ WHEEL AS PER IS 14846/2000 PN 1.0 WITH ISI MARKING All the valves should be with electrostatic powder coating both inside and outside with pocket less straight thro body passage, inside and outside color Blue includingFlange/socket and Flange/spicot tail pieces, etc., loading,unloading, Transportation chargesand stacking etc. complete as per specifications. All the valves are to be compatible for burried application with pressure rating . 99 For isolation/Control 100 500 mm Di gate valve 101 For Scouring 102 400mm Scour valve 103 Electromagnetic Flow Meter shall be a velocity sensing Electromagnetic type, microprocessor based signal converter, sealed housing, flanged tube meter for 1.0 Mpa working pressure, manufactured to highest standard available for mag-meters, equipped with minimum six digit digital totalizers, reading in units of (kilolitres/ cubicmeter) and shall be accurate within 0.5% of Measured value, shall operate within a range of 0.3m/sec to 4 m/sec and be constructed as follows:Meter tube (Sensor) shall be fabricated from stainless steel tube and use class PN10 flat face carbon steel flanges in accordance with IS 1538. These flanges shall be welded to the flow tube. The internal and external of the meter tube shall be blasted to near white and lined with hard rubber/ Polyurethrene/ PTFE preferably by SBR or EPDM. Meter tube shall have a constant nominal inside diameter offering no obstruction to the flow. The accuracy should be inclusive of linearity, hysteresis, repeatability, temperature and pressure effects Coil Housing shall be fabricated from stainless steel (SS 304) with Anticorrosive paint for corrosion resistance and welded to the tube providing a completely sealed environment for all coils, electrode connections and wiring harness capable of submerged or buried operation with IP 68 protection. Signal Converter shall be pulsed DC coil excitation type with auto zeroing. The signal converter shall be remotely mounted away from the meter. The converter shall indicate direction of flow and provide a flow rate indication and a total of flow volume for both forward and reverse directions.The converter shall provide an isolated 4-20 mA output into minimum 500-ohm load and a frequency output of a maximum of 0-10 KHZ and a scaled pulse output, Communication interface is RS485, HART output, . The microprocessor based signal converter shall have a selfdiagnostic test mode and a backlit display that continuously displays “Rate of Flow” and “Total Volume”. Converter shall be supplied with a programmable low flow drop out Higher flow and empty pipe zero return. The signal converter housing should be die-cast aluminium with glass window. The converter cum transmitter should be fully programmable form the front facia. The programming should be user friendly, self-prompting menu driven. Flowmeter test calibration certificate from FCRI, flow test lab/ NABL accredited lab to be furnished. 104 500 mm dia @ WTP inlet 105 supply and delivery ofKINETIC AIR VALVES FOR HANDLING MORE VOLUMES OF AIR IN PUMPING MAIN, DOUBLE ORIFICE KINETIC AIR VALVE CONFIRMING TO IS 14845 TAMPER PROOF DESIGN (PN-1) AND WITH 5 YEARS WARRANTY 106 200mm Air Valve for 500 mm Pipe Line 107 Construction of Valve Chamber ofin Brick work with CM 1:5 mix with RCC Slab 100 mm thick including cost and conveyance of all materials and labour charges to site etc., complete as per Standard specification 108 Air Valve chamber 109 Construction of Thrust blocks - with RCC M20 Grade concrete Earthwork - excavation and depositing on bank with an initial lead of 10 m and initial lift of 2 m in trenches (Hard stiff clay, stiff black cotton, hard red earth, shales, murram gravel, stoney 110 500mm - 90 Deg Bend 111 500mm - 45 Deg Bend 112 Brick work in Cement Mortar 1:5 (one cement and five sand) using country bricks 22x11x7cm for basement and superstructures including cost of scaffolding curing and finishing etc. complete 113 Upto 4.5m above Floorslab 114 Above 4.5m from floor level 115 Plastering with CM 1:5 12mm thick (one cement and five sand)including cost of all materials labour,curing etc.Complete complying with standard specification 116 Providing granolithic floor finish of 25mm thickness with plain cement concrete 1:2:4 (One Cement, Two crushed sand (M-Sand) and Four aggregate) using 10 to 12mm gauge hard broken stone jelly including laying, finishing and the top rubbed smooth with power trawl, thread lining, curing etc. complete complying with standard specification and as directed by the departmental officers. (The rate is inclusive of necessary planking for panellingwherever necessary and as directed by the departmental officers) 117 Special ceiling Plastering with CM 1:3 10mm thick (one cement and three sand) for R.C.C surface including cost of all materials labour,curing etc.Complete complying with standard specification 118 Weathering course with broken brick jelly concrete using20mm size brick jelly with pure slacked lime over RCC roof slab,the proportion being 32:12.5 for the requiring depth of 80mm with requiredslope,including beating thetop surface with wooden beaters etc.complete and finishing the top of the roof with one course of pressed tiles 20cm X 20cm X 20mm using CM 1:3 (one cement and three sand) mixed with crude oil by10% by weight of cement etc., completecomplying with standard specification 119 Painting two coats of newly plastered wall surface with ready mixed Cement paint of first quality and of approved colour over a priming coat including preparing the surface, clean removal of dirt and including necessary plaster of parts putty wherever required etc., complete complying with standard specification. 120 Supply, delivery and fixing in position of M.S.rolling shutter of following size inclusive of cost of holdfast wind appliances and iron furniture fittings and locking arrangements with two coats of colour painting over one coat of red oxide paint etc. complete compliying with standard specifications and as direvcted by Officers. (Gear operated type) 121 3.00 mx3.60m 122 Supply, delivery fabrication of M.S. Windows including cost M.S. angles of size 50mm x 50 mm x6 mm with 18 guage of M.S.plate, fabrication charges, cost of hold fast, and painting two coatsover one coatof red oxide paint,and transportation charges etc., complete and as directed by Officers. 123 1.20x 0.90 124 Supply, delivery fabrication of M.S. Vendilator including cost M.S. angles of size 502 mm x 50 mm x4 mm with 18 guage of M.S.plate, fabrication charges, cost of hold fast, and painting two coatsover one coatof red oxide paint,and transportation charges etc., complete and as directed by Officers. 125 0.45 mx0.60 m 126 Hire charges for using 7 Nos. of 12.5 HP Diesel pump sets with fuel at 12 hrs per day(Average) for 60 days required for dewatering and tailing out of water for concreting works inside well. 127 Providing GI Handrails as per specifications 128 MECHANICAL WORKS 129 Supply and delivery of Vertical water/oil lubricated statically, dynamically, hydraulically balanced turbine pump capable of discharging the following duty condition as given below due to all causes with surface discharge head confirming to IS 1710 and as amended as on date with accessories as per IS 5120/1977 (Reaffirmed 2011 ) to suit the site condition. The speed, No. of stages, sizes of column pipes and line shaft indicated is based on site condition prevailing during investigation. The pump should be supplied with non reversible ratchet pin housing safety clutch, suction strainer etc. The Pump Bowl assembly shall be with bronze impeller running at 1450 rpm. The pump includes suitable head shaft, suitable 1.5 metre long SS line shaft required Nos. to suit the well depth, Rubber line shaft bearing of required Nos., C.I Bearing retainer of required Nos., 100 litre HDPE Pre- lubricating tank with 20mm PVC Rigid pipe connection along with GM gate valves, Suitable ERW column pipe of each 1.5m long of required Nos. to suit the well depth, Suction bell mouth of suitable size, M.S. clamps suitable for column pipe/line shaft -2 set and Spanner - 1 set etc complete 130 5000LPM. Capacity @ 60 mts of total head for each Pump (2W +1S) 131 Supply and delivery of 150 kW vertical Solid shaft AC 3 Phase /415 V/ Vertical Solid Shaft TEFC &SPDP 4 Pole Squirrel cage Induction mortor 1500RPM(IS 325 / IS 12615) suitable for the above pump continuous rated TEFC/SPDP type with Class F insulation for operation in AC, 3 Phase/50 HZ (±5%), 415V (±10%) running with a speed of pump noted above and with inbuilt thrust bearing assembly capable of taking up the entire load and non - reverse ratchet assembly etc., complete. The motor rating noted above is the minimum and shall be such that it should never be over loaded when the pump works at MWL condition and shall be 10% over and above the maximum HP absorbed by the pump. The motor offered should be energy efficiency motors to have maximum efficiency at high power factor. Separate thrust bearing assembly could also be supplied to take up the down load. 132 Supply and Delivery of DI D/F Gate Valves (soft seated) resilient seated soft sealing gate valves (sluice valves) with body bonnet of ductile cast iron of grade GGG40, wedge fully rubber lined with EPDM, replaceable spindle nut, without gland packing and with 3 O-Ring protection on the shaft and seals of NBR and the valves should be of vaccum tight and 100% leak proof with face to face dimentions as EPR BS 5163-89/ ISI 14846-2000/ DIN 3202 F 4. All the valves should be with electrostatic powder coating both inside and outside with pocket less straight thro body passage. All lthe valves are to be compatible for burried application with pressure rating PN 16 133 350mm dia. PN 16 134 Supply and Delivery of DI D/F Butterfly Valves with GGG400/12 or equivalent grade as per IS 3896 (part 2) 1985 and subsequent revisions double ecentrically disc with renevable soft seal on the disc and body seat face of stainless steel / nickel weld overlay microfinished with powder or liquid epoxy coating with minimum thickness of 250 microns applied on both body and disc inside and outside face to face dimensions as per AWWAC 504 or BS 5155 or IS 13095 - PN16 135 500mm dia. PN16 136 Manufacture, supply and delivery of DI D/F Slanted seat Tilting Disc Swing Check Valve in single piece body and closed eye disc construction. Hemisherical disc with 59 degree inclination for fast open and closing. Corrosion proof and wear resistent(triple offset) disc face & body seat face, both made of fusion bonded Nickel Chromium weld overlay and microfinished. Body and disc of ductile cast iron GGG-40, medium free(dry) shafts of stainless steel and bearings of Zincfree Bronze, Valve should have provision for internal damping unit for reducing the effects of water hammer/surge, if required at later stage. Electrostatic epoxy powder/liquid coating(EP-P) inside and outside color blue RAL 5005 with minimum coating thickness of 150 microns. The EPDM rubber & Epoxy Powder should be approved by W 270.(EP-P it isa resi-coat powder approved for drinking water application, applied through fusion bonding technology process by dipping the shot-blasted casted components heated upto 200deg C). Face to face dimensions as per EN 558-1 series 14 and flange connections as per EN 1092-2/I - PN16 137 350mm dia - PN16 138 Supplying Ductile Iron D/F pipes coforming to IS 8329:2000 with latest amendments and conveying to work site, rolling and laying true to line, level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of DI pipes & specials excluding cost of specials and required to fixing of various valves, bulk flow meter on the line , jointing with flanged end to ends with rubber gaskets.jacking and fixing in perfect conditions and giving necessary hydraulic test to the required pressure as per ISS with all lead and lift including cost of jointing materials. (contractor will make his own arrangements for procuring water for testing) 139 350mm dia DI K9 D/F Pipe 140 500mm dia DI K9 D/F Pipe 141 Ductile iron fittings as noted below. DI pipes shallconform to class as per IS: 8329/2000 and pipe specials shall conform to IS: 9523/2000.All pipes and fittings shall be flanged and inter connected to the 600mm dia. pumping main. 142 Jointing following size DI D/F pipes and specials with rubber insertion or any equivalent to the required specifications with M.S bolts and nuts. Complete including charges for special tools and plants such as air compressor and helmets and sheet piles etc., 143 350mm dia 144 500mm dia 145 Supply, installation, testing and commissioning of Bourden type, stainless steel dial type pressure gauge with isolation valve and pipe having calibration of 0-16 kg/cm2. including necessary tools and plants complete as directed by site Engineer. 146 Supply and fixing of Electromagnetic Flow Meter conforming to ISO 17025 Standard shall be a velocity sensing excitation type with auto zeroing. The signal converter shall be remotely mounted away from the meter. The converter shall indicate direction of flow and provide a flow rate indication and a total of flow volume for both forward and reverse directions. The converter shall provide an isolated 4-20 mA output into minimum 500-ohm load and a frequency output of a maximum of 0-10 KHZ and a scaled pulse output. The microprocessor based signal converter shall have a self-diagnostic test mode and a backlit display that continuously displays “Rate of Flow” and “Total Volume.”Converter shall be supplied with a programmable low flow drop out and empty pipe zero return. The signal converter housing should be die-cast aluminium with glass window. The converter cum transmitter should be fully programmable form the front facia. The programming should be user friendly, selfpromptingmenu driven. Flow meter test calibration certificate should be provided with life cycle test certificate from FCRI/NABL accredited lab. Supply and fixing of Electromagnetic type, microprocessor based signal converter, sealed housing, flanged tube meter for 1.0 Mpa working pressure, manufactured to highest standard available for mag-meters, equipped with minimum six digit digital totalizers, reading in units of kiloliters and shall be accurate within 0.5% of Measured value, shall operate within a range of 0.3m/sec to 4 m/sec and be constructed as follows:Meter tube (Sensor) shall be fabricated from stainless steel tube and use class PN10 flat face carbon street flanges in accordance with IS 1538. These flanges shall be welded to the flow tube. The internal and external of the meter tube shall be blasted to near white and lined with hard rubber /Polyurethane/PTFE preferably by SBR or EPDM. Meter tube shall have a constant nominal inside diameter offering no obstruction to the flow. The accuracy should be inclusive of linearity, hysteresis, repeatability, temperature and pressure effects. Coil Housing shall be fabricated from stainless steel/SS304/Die cast Aluminium/Carbon Steel with Anticorrosive paint for corrosion resistance and welded to the tube providing a completely sealed environment for all coils, electrode connections and wiring harness capable of submerged or buried operation. Signal Converter shall be pulsed DC coil 147 Erection of water Lubricated / oil lubricated vertical tur¬bine pump with motor at site of work including prepa¬ration of suitable foundation and bed, fabrication of packer plates from raw materials , cutting required shims , assembling and joining of all required loose components such as bowl assembly, impellor shaft, line shaft, column pipes , head soft, discharge head, bearings, drive unit, delivery side pipes , suitable tap¬pers required valves and specials, pressure gauges and flow meters , adjustment of pump shaft and leveling and alignment checkup greasing of relevant compo¬nents, grouting of foundation bolts and sole plate with non shrink grout materials of conbextra GP-2 cement erection, connecting the relevant electrical cables with motor properly etc. complete and testing the out put and efficiency, site performance test for noise and vi¬bration and trial run for minimum 10 days and commis-sioning satisfactorily for the various HP of the vertical turbine pumpsets as given below per IE rules as directed by Officers. (150 HP) 148 5T capacity hand operated over head Travelling (HOT) crane suitable for a span upto 10 Mtrs, and travel length upto 10 M with clear lift upto 6 M including gear type chain pulley block and geared Travelling trolley complete with all accessories including Vertical ISMB 250 and Horizontal ISMB 350 149 Dewatering by using1 Nos. of Diesel Pumpsets of7.50 HP (Hire Charges) 150 Dewatering by using1 Nos. of Diesel Pumpsets of10.0 HP(Hire Charges) 151 Providing sand bags in the erected berms including cost and conveyance of sand, supply of empty bags, loading and unloading, filling in bags with sand, shuttering hem and planning and erected berms as directed by department officers etc., complete. 152 GST Amount for providing Service to Government Contract Works for the Above construction works. (GST Amount is the Total GST Amount for total overall quoted amount above this row for this work)
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 2
25.
Drinking Water Supply and Sanitation #9323157 Technical Bid
Supplying, Installation And Testing Of 02/03 H.P Submersible Pump Set, Rising Pipe Laying And Fittings And Allied Works Etc. At Air Port Campus Dumka For Newly Constructed Hydt. , Supplying And Fitting Of 02/03 Hp Submersible Pump Set Confirming To Is 8034 And Motor Confirming To Is 9283. Pump Shall Be Suitable For Various Delivery Head Discharge With Stainless Steel Pump Shaft And Polypropylene/ Noryl Impeller. Motor Suitable For Working On 415±10%, 3 Phase, 50 Hz A.C. Supply With Cable Guard, Thrust Carbon/ Fiber Bearing To With Stand Entire Hydraulic Thrust, Water Proof Winding Shall Be Provided. The Pump Set Shall Be Suitable For Direct Coupling, Pump Shall Have Suitable Outlet As Per Manufactures Design. Anti-Thrust Stream Lined Non Return Valve Shall Be Provided With Pump. 3 Mtr Submersible Copper Conductor Cables In Single/ Double Run Shall Be Provided With Each Pump. Submersible Pump Set 100 Mm Dia. (With Polypropylene/ Noryl Impeller) Up To 32 Stages. , Supplying And Fitting Of 3 Core 4 Sq. Mm Flat Flexible Submersible Cable, Copper Conductor, Pvc Insulated And Pvc Sheathed As Per Is:7098. , Cost Towards Supplying And Laying Of 1’’ Dia. Pvc Pipe For Submersible Cable Covering And Laying In Earth Or Open Space As Required At Site. , Supplying And Fitting Of Linen Rope For Lifting Of Submersible Pump Set. , 40 Mm Dia. Outer Dia. Upvc Column Pipe. Isi Mark, Standard Duty Make- Supreme/Finolex/ Any Reputed Make. , Supplying & Fitting Of 03 Hp, 3 Phase Submersible Pump Starter Having Suitable Contactor, Relay, On-Off Push Buttons, Voltmeter & Ampere Meter In Ss Enclosure, One Set Complete. Make-L&T/Havell’S/Any Reputed Make Isi Mark. , 32 Amp Tpn Main Switch L&T/Havell’S/Hpl Any Reputed Isi Make Havell’S/Any Reputed Make. , Cost Towards Supplying And Fitting Of 200 Mm Dia. Bore Cover-01 No., Bore Clamp-01 No. & Adaptor (Male & Female) As Per Requirement. , Cost Towards Supplying & Fitting Of 9 -14 Amp Current Rating Motor Protection Circuit Breaker Having Breaking Capacity 15Ka, 415 Volt, 50 Hz With Pvc Moulded Box Etc. L&T/Havell’S/Hpl/ Any Reputed Isi Make. , Cost Towards S/F Of 6.0 Sq.Mm Isi Marked Fr Ls Pvc Insulated Single Core Copper Conductor Cable. , Earth Work In Excavation (As Per I.S. 3114) 1965 For Laying Of 32 Mm Dia. Size Of Upvc Pipe So As To Give One Meter Average Cover Over The Socket Of Pipe With Disposal Of Excavated Earth Within Initial Lead And Left As Per Specification & Direction E/I. Upvc Pipe 32 & 40 Mm Dia.= 410M X 0.37Mx0.60M= 91.02M3 - 2 Nos X 91.02M3= 182.04M3 90% Of Total (As Per Soil Item Class A) , 10% Of Total (As Per Soil Item Class B) , Earth Work In Back Filling In The Trenches After Laying Different Sizes Of Pipe With Earth Removed During Excavation Lead & Lift As Per Specification & Direction Of E/I For Classification Of Soil Item A & B. , Supplying All Materials Labours Tools And Equipment For Laying In Groundof Isi Mark Upvc Pipe With Solvent Cement Including Cutting, Jointing Where Necessary Etc. All Complete As Per Specification And Direction Of E./I. Make-Supreme/ Asirwad/Astral/Reputed Isi Make. (I)40 Mm Dia. Upvc Pipe. , (Ii) 32 Mm Dia Upvcpipe , Supplying All Materials Labours Tools And Equipment For Fitting And Fixing Special Type Chrome Plated Upvc Fittings Of Approved Make All Complete As Per Specification And Direction Of The E/I. Make-Supreme/Ashirwad/ Astral/ Reputed Isi Make. 10% Of Pipe Line Cost. , Providing And Fixing Ball Valve Of Approved Quality All Complete As Per Specification And Directions. A. 32 Mm Dia.Upvc , B. 40 Mm Dia. Upvc , Carriage Of Following Materials To Work Site Including Loading Unloading And Taking Etc. All Complete As Per Building Specification And Direction Of E/I. (Ls 5%)
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
26.
Defence #9302961 Technical Bid
Design, Development, Supply, Commissioning And Training Of Large Cavitation Tunnel (Lct) Facility , Hydrodynamic Design Of Tunnel Including Acoustic Consideration To Meet Specifications , Hydrodynamic Design Of The Pump (Stator, Rotor And Its Associated Items) , Design Of Tunnel Steel Structure , Design Of Data Acquistion And Analysis System (Daas) & Acoustic Measurement System (Ams) , Design Of Automatic Control System (Acs) Of Lct , Design Of Condition Monitoring And Prognosis Systems , Design Of Complete Civil Structures, Rcc Building And Facility Infrastructure, Ergonomic Workspace Etc., Including Acoustic Considerationfor Setting Up Of Lct Facility , Verification And Validation Of Hydrodynamic Designs (Model Scale1:5) , Detailed Design: Detailed Technical Documentation, Drawings, Workshop Drawings, Bill Of Materials. , Quality Control And Quality Assurance Guidelines. , Detailed And Production Design Of Tunnel Steel Structure Of Lct And Verification Through Classification Society. , Raw Material, Fabrication, Errection,Testing,& Qa-Qc For Tunnel Steel Strcture, Storage Tank And Stiffeners (Ss Grade: Aisi 321)As Per Design , Raw Material, Fabrication, Errection,Testing,& Qa-Qc For Supprot Structures As Per Design , Shaft, Shaft Seal, Sealants And Its Associated Items And Its Associated Items , Impeller (Stator, Rotor) And Its Associated Items , Thrust Bearing And Its Associated Items , Bearings And Its Assocaited Items , Gear Box / Coupling And Its Associated Items , Forced Lubricating System And Its Associated Items , Misc Water Pumps And Its Associated Items , Water Filtration & Treatment Plant With Multi Step Filters And Its Associated Items , Special Tools, Tackles & Gadgets For Day Operations Of Lct , Other Misc Ppe, Accessories & Auxiliaries, Sound Mufflers Etc., , Degassing System And Its Associated Items , Automatic Controlled Valves And Its Associated Pipelines , Compressor Pumps, Compressed Air Storage Tanks And Its Associated Systems , Vacuum Pumps, Vaccum Storage Tanks And Its Associated Systems , Jigs, Fixtures, Calibration Masters, Tools And Tackles, Gauges ,Maintenance Kits Etc., , Battery Operated Trolley Of 3T Load Carry Capacity , Fork Lift03 Ton Capacity , Hydraulic Hand Pallet Truck (1.5 T) , Fully Electric Stacker(1.5T) , Main Propulsion Motor (Approx 7.5 Mw) With Vfd And Its Associated Systems , Major Switch Yard Equipment And Its Associated Systems (Transformers, Circuit Breakers, Lightning Arrestors, Isolaters, Control And Relay Panels, Power Cables And Control Cables, Switch Gear Panels, Earthing System Etc., ) , Central Fire Alarm & Detecting System Covering The Main Propulsion Motor Room. , Propulsion Dynamometer For Self-Propulsion Tests Along With Electric Drive (Rpm : 3000; Thrust:3000 N; Torque: 150 Nm) , Propeller Open Water Dynamometer Along With Electric Drive (Rpm : 3000; Thrust:3000 N; Torque:150 Nm) , Contra-Rotating Dynamometer Along With Electric Drive(Rpm:3000;Thrust : 1500 N;Torque:75 Nm For Each Shaft) , Single Component Dynamometer (Force:+/- 3000 N) , One Component Duct Dynamometer (Force:+/- 3000 N) , Towed Two Component Dynamometer Of Underwater Models (X- Force : +/- 3000 N Y- Force: +/- 3000 N) , Towed One Component Dynamometer For Surface Models With Suspension System And Replaceable Measuring Elements 2 In Nos. For Thegiven Range Each I. X –Force: +/- 3000 N; Ii. X- Force: +/- 1000 N;Iii. X –Force: +/- 300 N , Six Component Dynamometer X-Force:+/- 2500 N; Y-Force:+/- 8000 N;Z-Force :+/- 8000 N,Mx-Moment: +/- 1500 Nm; My-Moment:+/- 3500 Nmmz-Moment:+/- 3500 Nm , Propeller Unsteady Force Dynamometerrpm: 800;?T-Force:+/-10N , Hydro-Acoustic Measurement Units Like Hydrophones With Amplifier And Calibrators As Follows : Hydrophones , Pressure Fluctuation Sensors/Transducers , Accelerometers , Wake Rakesystem , High Speed Camera System (1024 X 1024 Pixels At 4000 Fps) , Stroboscopes , Hydraulic Drive /Electric Drive In Pod Unit With A Capacity Of Up To 10 Kw On A Shaft With A Rotation Speed Up To 2400 Rpm, Noise Level Should Be Less Than 80Db At 2400 Rpm. , Calibration Rigs (Including Dead Weights)For All The Instrumentation , Realisation Of Calibration Models And Its Associated Itemsa. Reference Ship Model(S) B. Reference Submarine Model(S)C. Reference Propeller Model(S) , Data Acquisition And Analysis System (Daas) With Provision For Extrapolation To Full Scale And Its Associated Systems. , Tunnel Automation Control System (Tacs) And Its Associated Systems. , Conditioning Monitoring / Prognosis /Diagnosis Software(S) And Its Associated Systems. , Standard Software Modules For High Speed Image Analysis And Results Reporting. , Acoustic Measurement And Analysis Andprediction System , Digital Simulator Of Lct Operations For Training To Future Incumbent Human Resources/Train The Workforce, Digital Walkthrough Of Lct Systems And Facility. , Hpc Cluster Servers With Ha , Rack Mountable Nas With 100Tb , Access Switch Type 2 (48-Port) , Work Stations For Cad Centre , Personal Computers , Printers Cum Document Scanners A3 Size , Multi-Function Documentation Machines A3 Size , Plotter A0 Size Colour Printing , Online Ups Of Rating 20 Kva With Battery Of Backup Time 60 Minutes , Access Control Systems , Cc Tv Cameras , Interactive Panel , 4K Resolution/Higher Configuration Projector , Conference Hardware, Speakers Cum Mickes & Cameras (Wire Free), Panels, Controls Etc. With Suitable Video Conferencing System, For 50 Delegate Capacity Conference Room , Site Survey, Geo Technical Investigations, Levelling And Construction Of Motarable Approach Road,Civil, Structural & Architectural Design And Structural Analysis Reports. , Construction Of Main Plant Building To Meet The Acoustic Quality Requirements Of Facility (Refer To Civil Drawings In Annexure Iii ) Including Finishing, Plumbing, Sanitation And Internal Electrical, Lighting And Works Etc., Meeting The Approved Civil And Architectural Plan Of Interior And Exterior Details. , Air Conditioning Plant/Hvac System For Various Offices Of Facility , Electrical Sub-Station And Associated Systems To Cater Electrical Energy Of Impeller Pump As Well As Electrical Supply For Entire Facility Operations. , Solar Power System(400 Kwh Energy Capacity) Transformer, And Associated Equipment , Dg Power Supply Systems (Dg Set-1.5 Megawatt Capacity) And Associated Equipment With Canopy. , Furniture, Office Storage Solution And Inbuilt Cupboards/Almarah, Operation Crew Announcement And Digital Displays Systems , Landscape Lighting, Routing Displays, Facility Display Systems,Arboriculture And Outdoor Aesthetic , Office Amenities, Light Roof For Parking Space, Hard Stand , Pavement Road Illumination Provisions,Ventilation Ducts, Glass Panels For Viewing Gallery, Walk Ways, Rails , Guards,“Divyangan”Facilitation Provisions ,Name Boards, Sign Plates Etc., , Electric Overhead Cranes -15 T Capacity & Its Associated Items , Material/Service Lifts (4 Ton Capacity) & Its Associated Items , Passenger Lifts (High Speed, 8 Persons Capacity) & Its Associated Items , Factory Acceptance Trials Of Major Equipmets And Subsystems , Training Of Nstl Specialist At Designers Large Cavitation Tunnel Facility. , Validation Trails At Designer Large Cavitation Tunnel Facility. , Training Of Nstl Specialist At Nstl Large Cavitation Tunnel Facility , Acceptance And Validation Trials At Nstl Large Cavitation Tunnel As Per Acceptance Criteria , Training Documentation , Warranty Chargesfor Mandatory Warranty Period Of 2 Years Post Commissioning. , Deployment Of Service Cum Maintenance / Support Engineers And Skilled Workforce Equipped With Required Esp. , Comprehensive Design Documents, Test Reports, Maintainance Procedures, Test Procedures And Literatures As Specified In Technical Specifications (Including One Set Of Soft Copy). , Accreditation And Certification Of Lct To Classification Societies / Global Professional Societies Physical Facilty Display Model, Digital Walkthrough Of Lctfor Presentation And Other Facility Anouncement Systems , List Of Recommended Critical Spare Parts For Thelct Equipment And Instrumentation Required Post Two Year Warranty Period And Amc Charges Post Warranty (I) Seven Years For Mechanical Components With Price Indication.(Ii) Five Years For Electronic & Electrical Components With Price Indication.(Iii) Comprehensive Annual Maintainance Charges For A Period Of 3 Years Post Warranty Period. Note: This Price Will Not Be Considered For Finilising The L1
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 4
Andhra Pradesh View Result →
27.
Housing Urban and Rular Development #9285076 Technical Bid
Miscellaneous Works A ) Edge Devices ( Cameras End, Node End, Poles, Juction Side ) , Supplying, Erecting, Testing & Commissioning Of Bullet Camera 5Mp Ir Vari-Focal Bulletnetwork Camera > 5-Mp 1 / 2.7 Cmos Image Sensor, Low Luminance, And High Definition Image.Outputs Max. 5 Mp ( 2592 × 1944 ) @20 Fps, And Supports 4 Mp ( 2688 × 1520 ) @25 / 30 Fps. Interoperability Storage Ftp; Sftp; Micro Sd Card ( Support Max. 256 Gb ) ; Nas Onvif ( Profile S / Profile G / Profile T ) ; Cgi; P2p; Milestone; Genetech.265 Codec, High Compression Rate, Ultra-Low Bit Rate.Built-In Ir Led, And The Max. Illumination Distance Is 60 M.Roi, Smart H.264+ / H.265+, Flexible Coding, Applicable To Vrious Bandwidth And Storage Environments.Rotation Mode, Wdr, 3D Nr, Hlc, Blc, Digital Watermarking, Applicable To Various Monitoring Scenes.Intelligent Monitoring: Intrusion And Tripwire ( The Two Functions Support The Classification And Accurate Detection Of Vehicle And Human ) .Abnormality Detection: Motion Detection, Video Tampering, Scenehanging, Audio Detection ( Only - Zas Supports ) , No Sd Card, Sd Card Full, Sd Card Error, Network Disconnection, Ip Conflict, Illegal Access, And Voltage Detection.Alarm: 1 In, 1 Out ( Only - Zas Supports ) ; Audio: 1 In, 1 Out ( Only - Zas Supports ) .Supports Max. 256 G Micro Sd Card.12 Vdc / Poe Power Supply, Easy For Installation.Ip66 Protection. > Smd Plus. Network Network Portrj-45 ( 10 / 100 Base-T ) Sdk And Apiyesnetwork Protocolipv4; Ipv6; Http; Tcp; Udp; Arp; Rtp; Rtsp; Rtcp , Supplying, Erecting, Testing & Commissioning Of 5Mp Ir Vari-Focal Dome Network Camera > 5Mp, 1 / 2.7” Cmos Image Sensor, Low Illuminance, High Image Definition Outputs Max. 5Mp ( 2592 × 1944 ) @20 Fps, And Supports 2688 ×1520 ( 2688 × 1520 ) @25 / 30 Fps Support Triple Stream Lens Type Motorized Vari-Focal Gain Controlauto / Manualnoise Reduction3d Dnrmotion Detectionoff / On ( 4 Areas, Rectangular ) Region Of Interest ( Roi ) Yes ( 4 Areas ) H.265 Codec, High Compression Rate, Ultra-Low Bit Ratebuilt-In Ir Led, Max Ir Distance: 40 M Roi, Smart H.264+ / H.265+, Flexible Coding, Applicable To Various Bandwidth And Storage Environments Rotation Mode, Wdr, 3D Nr, Hlc, Blc, Digital Watermarking, Applicable To Various Monitoring Scenesintelligent Detection: Intrusion, Tripwire Abnormality Detection: Motion Detection, Video Tampering, No Sd Card, Sd Card Full, Sd Card Error, Network Disconnected, Ip Conflict, Illegal Access, Voltage Detectionalarm: 1 In, 1 Out; Audio: 1 In, 1 Out; Supports Max. 256 Gb Micro Sd Card12v Dc / Poe Power Supply Video Video Compression H.265; H.264; H.264B; Mjpeg Smart Codecsmart H.265+ / Smart H.264+Ip67, Ik10 Protection Grade Audioaudio Compressiong.711A; G.711Mu; G.726; Aacnetworknetworkrj-45 ( 10 / 100 Base-T ) Protocolipv4; Ipv6; Http; Tcp; Udp; Arp; Rtp; Rtsp; Rtcp; Rtmp; Smtp; Ftp; Portaudio Input1 Channel ( Rac Port ) Audio Output1 Channel ( Rac Port ) Alarm Input1 Channel In: 5Ma 5Vdc , Supplying, Erecting, Testing & Commissioning Of Ptz Camera 4Mp 32X Starlight Ir Wizsense Network Ptz Camera 1 / 2.8 4Megapixel Starvis™ Cmospowerful 32X Optical Zoommax. 25 / 30 Fps@4M Ir Distance Up To 150 M Deep-Learning-Based Auto Tracking And Perimeter Protection Smd Plus Poe+Ip67, Ik10face Detectionfocal Length 4.8 Mm–154 Mm Max. Aperture F1.6–F4.0Field Of Viewoptical Zoom 32×Focus Controlauto; Semi-Auto; Manualclose Focus Distance0.8 M–5.0 M ( 2.62 Ft–16.40 Ft ) Iris Controlauto; Manual Ptzpan / Tilt Rangepan: 0° To 360° Endless Tilt: –15° To +90°, Auto Flip 180°Manual Control Speedpan: 0.1°–300° / S Tilt: 0.1°–200° / Spreset Speedpan: 400° / S; Tilt: 300° / S Preset300tour8 ( Up To 32 Presets Per Tour ) Pattern5scan5power-Off Memoryyes Intelligencesmart Capturesupport Human, Motor Vehicle And Non-Motor Vehicle Image Capture.Ivs ( Perimeter Protection ) Tripwire And Intrusion. Support Alarm Triggering By Target Types ( Human And Vehicle ) . Support Filtering False Alarms Caused By Animals, Rustling Leaves, Bright Lights, Etc.Face Detectionyesauto Trackingyessmd Plusyes Porttwo-Way Audioyes Videovideo Compressionsmart H.265+; H.265; Smart H.264+; H.264B; H.264M; .264H; Mjpeg ( Sub Stream ) Streaming Capability3 Streamsresolution4m ( 2560 × 1440 ) ; 3M ( 2048 × 1536 ) ; 1080P ( 1920 × 1080 ) ; 720P ( 1280 × 720 ) ; Video Frame Ratemain Stream: 4M / 3M / 2M / 1.3M / 720P ( 1-25 / 30 Fps ) Network Portrj-45 ( 10 / 100 Base-T ) Network Protocolhttp; Https; Ipv4; Rtsp; Udp; Smtp; Ntp; Dhcp; Dns; Ddns; Ipv6; 802.1X;Interoperabilityonvif Profile S&G&T; Cgistreaming Methodunicast; Multicas , Supplying, Erecting, Testing & Commissioning Of Anpr Camera 4 Mp Aicamera 1 / 1.8 4 Mp Starlight Cmos Sensor.Video Compression Standards: H.265, H.264M, H.264H And Mjpeg. Maximum Resolution: 2688 × 1520@25 Fps.Motorized Vari-Focal Lens: 10 Mm-50 Mm.Max Anpr Ir Distance: 30 M.Protection: Ip67, Ik10 Rated.Under Recommended Installation And Lighting Conditions: Capture Rate > 99% Lpr Accuracy > 98%Lens Motorized Vari-Focalfocal Length 10 Mm–50 Mmmax. Aperturemax. F1.33 Intelligencetarget Detectionmotor Vehicle; Motorcycleanpradopts Developed Algorithms To Recognize License Plate Numbers And Lettersvehicle Type Recognitionvehicle Head: Suv, Large Bus, Sedan, Light Truck, Pickup, Heavy Truck, Medium Truck, Van, Medium Bus, Mpvvehicle Tail: Suv, Large Bus, Sedan, Light Truck, Pickup, Heavy Truck, Medium Truck, Vanvehicle Color Recognitionwhite, Pink, Black, Red, Yellow, Gray, Blue, Green, Dark Orange, Purple, Brown, And Silver Gray Network Port1 × Rj-45 Ethernet Port, 10 / 100 / 1000 M Network Transmissionsdk And Apiyessecurity Authorized Username And Password, Mac Address Binding, Https Encryption, And Network Access Controlprotocolipv4; Ipv6; Http; Tcp; Ip; Udp; Ntp; Dhcpinteroperabilityonvif ( Profile S / Profile G / Profile T ) Portstorage1, Supports Maximum 512 Gb Tf Card Local Storagers-4852, Connects To Devices Such As Radarsrs-232, Con Is Used For Serial Debugging And R T G Is For Connecting To Radarsaudio Input1 Channelaudio Output1 Channelalarm Input3 Channelsalarm Output2 Channels. 2 For Relay , Camera Brackets Enclousers Hosing Box Secure Outdoor Weatherproof Heavy Duty Aluminium Cctv Security Surveillance Camera Housing Mount Enclosure. The Mx Outdoor Camera Housing With Back Opening Is Made Of Heavy-Duty Stainless Steel That Makes The Unit Strong And Durable. You Can Easily Access The Camera Via The Front Hinged Cover And Back Which Prevents Unauthorized Access. Adjustable Camera Tray And Top Swings Open Make For Easy Installation And Service. Cctv Camera Stand Will Hold A Camera Up To 25 Kg Without Introducing Unwanted Resonance To Its Video. , Supplying, Installing And Testing Utp Connector ( Rj-45 ) As Per Specification No. Wg-Nas / Utpc. , Rj45 Junction Cat5e Connector Wall Port Desktop Extension Cable Box Adapter Lan Ethernet Network Modules Accessories , Supplying And Installing Cat-6 Outdoor Stp Cable Suitable For Cable For Security Camera Networking 4-Pair Shielded Twisted Pair Cable, High Density Polyethylene Insulation, Fr Pvc Jacket With Neccessary Support Of Wire Rope. , Supplying, Fixing, And Configuring 8-Ports Managed Gigabit, Layer-2 Switch, 10 / 100 / 1000 Base-T, Poe+ Smart Switch Plus 2 Sfp Erected In Provided Rack Complete. , Supply, Installation, Testing And Commissioning Of 1000 Mbps Sfp Module For Level 2 Managable Switch Includingstandards And Protocols Ieee 802.3Z, Csma / Cd, Tcp / Ip Wave Length 1310 Nm Power Supply 3.3 V Safety & Emission Fcc, Ce Cabel Single-Mode Fiber Fiber Type 9 / 125 ?M Single-Mode Max. Cable Length 10Km Data Rate 1.25 Gbps Port Type Lc Duplex Environment Operating Temperature: 0–70 °C ( 32–158 °F ) Storage Temperature: -40–85 °C ( 40–185 °F ) Operating Humidity: 10–90% Rh, Non-Condensingstorage Humidity: 5–90% Rh, On Site Warrenty , 1M Length, Utp Patch Cord Of Enhanced Cat 6 Type With 4-Connector Channel, Performance Test Report As Per Ansi / Tia-568.2-Din Position As Per Specification No. Wg-Coc / Pc , Supplying, Fixing, And Configuring 8-Ports Managed Gigabit, Layer-2 Switch, 10 / 100 / 1000 Base-T, Poe+ Smart Switch Plus 2 Sfp Erected In Provided Rack Complete. , Outdoor Wall Mount / Pole Mount Ip65 Outdoor Rackenclosure Provides Protection From Level Of Harmful Dust And Provide Protection From Low Pressure Water Jet And Complete Protection From Rain Water Usability-Network Switches, Telecom, Surveillance, Network & Surveillance Backup, Fiber Management System Front Door-Lockable Steel Door With Gasket Sealing, 2 Fan Option For Hot Air Execution Cable Entry Cut-Through Pg Ip Glands2 Pair Heavy Duty ( 1.5Mm ) Verticalmounting Rail For Equipment Mounting, Height As Per Rack Unitcooling Option-2 Ac / Dc Fan Provision Mounted On Front Door Galvanized Steelconstruction 1.2Mm Thick Load Bearing Angles Are 1.6 Mm , Supplying And Installing 6 Port Single Mode Fibre Adapter With Plate Complete. , Supplying And Fixing Ip66 Enclosure, Joint Box Sleevs, Fiber Fusion Splicing Complete. , Providing & Fixing, Erecting Cctv Octagonal Pole6 M High Galvanised Octagonal Pole With Foundation Bolts Having Min 70 Mm A / F On Provided Foundation For Camera Mounting On The Pole With Necessary Accessories , Cantilever On New / Existing Pole 50 Dia Mm / Or As Per Requirements, Min 6 Feet Or As Per Requirements 40 For Camera Mounting On The Pole, Fabrication And Brackets And Etc , Supplying And Erecting Mains With 3X 1.5 Sq.Mmfrlsh Copper Pvc Insulated Wire Laid In Provided Conduit / Trunking / Inside Pole / Overhead Cctv Camera / Anpr System , Supplying And Fixing Power Distribution Unit For Networking Rack Comprises Of 6 / 16A , 25 A Modular Mcb, Appropriate Rating Fuse, Earthing And Indicator Lamp, With Necessary Arrangement For Fixing At Above Camera Junction Locations Ready For-Msedcl Connection , Supplying Laying And Erectingarmoured Multimode Optical Fibre Cable With 6 / 12 Fibres, Core Dia 50 / 125 ?M ( Om3 ) , Suitable Up To 10 Gbps Ethernet Distance At 850 Nm Of Wavelength With Necessary Support Of Ms Wire / Rope. , 256 Gb Sd Card Supply Installation Of Surveillance Grade 128 Gb Storage Disk, Range150mb / S Rcompatible With Wifi Camera, Operating Temp 0ºc To 70ºc, Storage Temperature -40ºc To 70ºc Including Segate, Ultra-Strong Adaptability­ Waterproof, Shockproof, X-Ray Proof, Wide Temperature , Ir Illuminator - 50 Meter Material Aluminiumled Type 9Pcs 2W Dot-Matrix Ir Led Panel High Light Transmittance Toughened Glass Beamangle 60° Day And Night Switch Auto ( Build In Photocell ) Ir 50 Mtr. Voltage Poe Ieee 802.3At Operating Temperature -40°C To 50°C Power Consumption 22W ( 850Nm ) Cable Length Ip66 Rj45 Jack With Cat .5E 50Cm Weatherproof Standard Ip66 & Ik10 , B ) Data Center Infrastructure Servers, Storage, Application Software, Etc. At Control Room , Supplying, Erecting, Testing & Commissioning Of 32Ch 3U 16Hdds Network Video Recorder Supports Smart H.265+, H.265, Smart H.264+, H.264 And Mjpeg Decoding Formats. Max. Decoding Capability: 32 × 1080P@30 Fps. Max. 1280 / 1280 / 1024 Mbps Incoming / Recording / Outgoing Bandwidth. Supports Acupick With Up To 32 Channels.Ai By Recorder Supports 8-Channel Face Detection And Recognition, Up To 40 Face Databases And 300, 000 Face Images; 8-Channel Metadata; 32-Channel Perimeter Rotection; 32-Channel Smd Plus. Ai By Camera Supports Face Detection And Recognition, Perimeter Protection, Smd Plus, Metadata, Anpr, Stereo Analysis, Heat Map, And People Counting. Supports N+M Cluster, Raid 0 / 1 / 5 / 6 / 10, Iscsi, Drawer-Like Chassis Design Allows For Hdd Hot Swapping. Supports Eptz, One-Click Arming & Disarming. Security Baseline 2.3 Network Protocol Http; Https; Tcp / Ip; Ipv4 / Ipv6; Udp; Snmp; Ntp; Dhcp; Dns; Smtp; Upnp; Ip Filter; Pppoe; Ftp; Ddns; Alarm Server; Multicast; P2p; Auto Registration;Iscsi Mobile Phone Access Ios; Android Interoperability Onvif 22.06 ( Profile T; Profile S; Profile G ) ; Cgi; Sdk Network Mode Multi-Address; Load Balance; Fault Tolerance Storage Disk Group Yes Raidraid 0 / 1 / 5 / 6 / 10Hot Swapping Yes Audio Input 1-Channel Rcaaudio Output 2-Channel Rca Alarm Input 32 Channels Alarm Output 16 Channels Hdd Interface 16 Sata Ports, Each Disk Can Contain Up To 20 Tb. This Limit Varies Depending On The Environment Temperature. Esata 1 Rs-232 1 Rs-485 2 ( 1 Port For Half-Duplex Serial Communication, 1 Port For Full-Duplex Serial Communication ) Usb 4 ( 2 Front Usb 2.0 Ports, 2 Rear Usb 3.0 Ports ) Hdmi 4 Vga2 Network Port 4 Wizmind ( 10 / 100 / 2500 Mbps Ethernet Port, Rj-45 ) , Supplying, Erecting, Testing & Commissioning Of 64Ch 3U 16Hdds Wizmind Network Video Recordersupports Smart H.265+, H.265, Smart H.264+, H.264 And Mjpeg Decoding Formats. Max. Decoding Capability: 32 × 1080P@30 Fps. Max. 1280 / 1280 / 1024 Mbps Incoming / Recording / Outgoingbandwidth.Supports Acupick With Up To 64 Channels. Ai By Recorder Supports 8-Channel Face Detection And Recognition, Up To 40 Face Databases And 300, 000 Face Images; 8-Channel Metadata; 32-Channel Perimeter Protection; 32-Channel Smd Plus.Ai By Camera Supports Face Detection And Recognition, Perimeter Protection, Smd Plus, Metadata, Anpr, Stereo Analysis, Heat Map, And People Counting.Supports N+M Cluster, Raid 0 / 1 / 5 / 6 / 10, Iscsi, Drawer-Like Chassis Design Allows For Hdd Hot Swapping.Supports Eptz, One-Click Arming & Disarming. Security Baseline 2.3. Ystem Main Processorindustrial-Grade Processor Operating Systemembedded Linux Operating Interfaceweb, Local Gui Aiai By Recorderface Detection; Face Recognition; Video Metadata ( Human, Motor Vehicles, And Non-Motor Vehicles ) ; Perimeter Protection; Smd; Anprai By Cameraface Detection; Face Recognition; Video Metadata ( Human, Motor Vehicles, And Non-Motor Vehicles ) ; Perimeter Protection; Smd; Stereo Analysis, Crowd Distribution; People Counting; Anpr; Heat Map; Ppe Detectionacupick Ai By Camera + Recorder Max. 64-Channel, 1 Combined Event Per Channel / Svideo Metadatametadata Performance Of Ai By Recorder ( Number Of Channels ) 8 Channels, 23 Attributes Extraction.Metadata Performance Of Ai By Camera ( Number Of Channels ) 64Channels People Attributes9 Human Body Attributes Motor Vehicle Attributes9 Attributesnon-Motor Vehicle Attributes4 Attributeshttp; Https; Tcp / Ip; Ipv4 / Ipv6; Udp; Snmp; Ntp; Dhcp; Dns; Smtp; Upnp; Ip Filter; Pppoe; Ftp; Ddns; Alarm Server; Ip Search; Multicast; P2p; Auto Registration;Iscsimobile Phone Accessios; Androidinteroperability Onvif 22.06 ( Profile T; Profile S; Profile G ) ; Cgi; Sdk Multi-Address; Load Balance; Fault Tolerance Ortaudio Input1-Channel Rcaaudio Output2-Channel Rca Alarm Input32 Channelsalarm Output16 Channels Hdd Interface16 Sata Ports, Each Disk Can Contain Up To 20 Tb. This Limit Varies Depending On The Environment Temperature.Esata1rs-2321Rs-4852 ( 1 Port For Half-Duplex Serial Communication, 1 Port For Full-Duplex Serialcommunication ) Usb4 ( 2 Front Usb 2.0 Ports, 2 Rear Usb 3.0 Ports ) Hdmi4vga2network Port 4 ( 10 / 100 / 2500 Mbps Ethernet Port, Rj-45 ) , Supplying, Erecting, Testing & Commissioning Survilliance Grade 10 Tb Hdd Compatible With Nvr, Interface Sata Transfer Rate Up To 175Mb / S Disk Speed ( Rpm ) Recording Technology Cmr 256 Mb Cache, Operating Temp 0ºc To 70ºc, Storage Temperature -40ºc To 70ºc Including Segate, Western Digital On Site Warrenty , Supplying, Erecting, Testing & Commissioning Of Display Unit65resolution: 4K Ultra Hd ( 3840X2160 ) | Panel Technology Edge Led Blu 3840 X 2160 Brightness 350 Nitcontrast Ratio ( Typical ) 4000:1 Contrast Ratio ( Dynamic ) Mega Viewing Angle ( H / V ) 178 / 178 Response Time 8Ms ( Typ. ) Connectivity Input Rgb: Dvi-D Video: Hdmi 2.0 ( 2 ) Hdcp: Hdcp 2.2 Audio: Stereo Mini Jack, Dvi / Hdmi / Audio ( Common ) Usb: Usb 2.0 X 2Output Audio: Stereo Mini Jackexternal Controlrs232c ( In / Out ) Thru Stereo Jack, Rj45 Sensor Ir Powerpower Supply Ac 100 - 240 V~ ( + / - 10 % ) , 50 / 60 Hzhardware: Temperature Sensor, Pivot Display, Clock Battery ( 168Hrs Clock Keeping ) , Built In Speaker ( 10W 2Ch ) , Ip5x Rating, Wi-Fi / Bt Software: Auto Source Switching & Recovery, Lfd Home Ui, Button Lock, Hot Key Option, Plug&Play ( Initial Setting ) Smart Signage Platform Yesplug & Play Yeswi-Fi Yesspeaker Type Built In Speaker ( 10W + 10W ) Internal Playerprocessor Coretex A72 1.7Ghz Quad-Core Cpu On-Chip Cache Memory L1 Instruction Cache : 48Kb L1 Data Cache : 32Kb L2 Cache : 2Mbclock Speed 1.7Ghzmain Memory Interface 2.5Gb Lpddr4 1.5Ghz 64Bitgraphics Graphic Resolution : 1920 X 1080 Output Resolution : 3840 X 2160 ( Scale Up From Graphic Processing Result ) Storage 8Gb ( 3.88Gb Occupied By O / S, 4.12Gb Available ) Multimedia Video Decoder: Mpeg-1 / 2 / 4, H.263, H.264 / Avc, Uhd H.264 / Avc, Vc-1, Avs+, Hevc, Jpeg, Png, Vp8, Vp9 Audio Decoder: Ac3 , Matrix Controler With One Card 4Ch Hdvm Input & Outputmulti-Service Video Management Platform > 19” Standard 4U Atca Industry Box > Easy And Flexibleonfiguration With Pluggable Card Module Design > 40Ch@1080P Signal Encoding ( Full Configured ) > 20Ch@32Mp Or 80Ch@8Mp Or 320Ch@1080P Or 720Ch@720P Or 1280Ch@D1 Signal Decoding ( Full Configured ) > Support 240@D1 Nonstandard Stream Signal Decoding ( Ful Configured ) > Support 240@D1 Nonstandard Stream Ignal Decoding ( Full Configured ) > Support Max 60 Screens Splicing > Support Analog / Digital Video Signals Input And Matrix Output > Support Sd / Hd Video Signal Matrix Switch And Output > Support Non-Compressed Digital Signal Encoding Output > 6 Rj-45 Gigabit Network Ports For Matrix Control, Preview And Online Central Storage > Supportip / Rtp / Rtsp / Rtcp / Tcp / Udp / Dhcp / Pppoe And Etc. Network Protocols > Remote Cast Analog / Digital Video Onto The Video-Wall > Remote Reboot / Upgrade / Default Setting And Etc. Operations , Network Control Keyboard Joystick Four Dimensional Joystick Control Of Ptz Functions Rs232, Rs485 And Network Connections ( Wi-Fi ) Preset Position, Auto Scan, Auto Pan, Auto Tour & Pattern Control Support 4K Decoding Live View Support 4Ch Hdmi Output Support Snapshot And Recording To U-Disk Support Video-Wall Display Control And Bidirectional Talkauxiliary Functions, Osd And Operation Guides Control Keyboard Keypanel Electromechanical Joystick Four Dimensional Keyboard Communication 1 Rs485, 2 Rs232, 1 Rs422 Direct Mode Interface: Rs232 / Rs485 Power Source Dc12v, 4A , Supplying And Fixing Floormount Server Rack 42U Network Enclosure Frame-800X1000-Steel Nos 1Casters Set Of 4 Nos 1 Adjustable Levelers Set Of 4 Nos 119 Reduced Channel - Loop Type Nos 1Glass Door-800-42U Nos 1Metal Door-800-42U-Vented Dual Nos 1 Side Panels-1000-42U-Vented ( Set Of 2 ) Set 1 Mounting Hardware- ( Pack Of 20 ) Set 5 Shelf Nos 2Shelf Support Angles Nos 419Earthing Kit Nos 1 Fhu With 4 Fan 360Cfm Nos 1 2U Horizontal Power Distribution Unit With 6 X 5 / 15Asockets Round & Flat Pin, 230 Volts Ac, 16 Amp With Plugnos 3 Horz. Cable Manager-1U-Loop Nos 1 , 32U Network Enclosure Frame-800X1000-Steel Nos 1 Castors Set Of 4 Nos 1 Adjustable Levelers Set Of 4 Nos 1 19” Reduced Channel- Loop Type Nos 1 Glass Door-800-32U Nos 1 Metal Door-800-32U-Vented Dual Nos 1 Side Panels-1000-32U-Vented ( Set Of 2 ) Set 1 Mounting Hardware- ( Pack Of 20 ) Set 5 Shelf Nos 2 Shelf Support Angles Nos 419Earthing Kit Nos 12U Horizontal Power Distribution Unit With 6 X 5 / 15A Sockets Round & Flat Pin, 230 Volts Ac, 16 Amp With Plug Nos 3 Fhu With 4 Fan 360Cfm Nos 1 Horz. Cable Manager-1U-Loop Nos 1 19Earthing Kit Nos 1 , Supply, Installation, Testing & Commissioning Ofvideo Management Software System Analytic Software With Distributed Architecture To Collect, Manage And Present Video From All The Cameras And Supports Emerging Technologies In The Industry, Like 4K Resolution, H.265 Video Compression Codec, Multi-Imager / Lens Cameras And 360° Fisheye Cameras. N+1 Recording Server Failover To Be Considered For Increased System Reliability. Vms Shall Support Recording Servers From A Multiple Location Licenced For 128 Cameras & 2 Users Clients, Licenses Should Expandable Upto 1000 Cameras & 10 User Clients Without Any Additional Version Upgrade. The Vms Should Support Network Joystick Controller, Gpu Rendering Support For H.264 And H.265 Decoding , Video On Demand, Adaptive Video Throttling, Rule Engine, Operatore Role Management, Server Based Video Motion Detection ( Vmd ) , Edge Storage Backfill Support, Bookmark With Manual Comment, Bookmark Based Search, Timeline Search, Preview Search, Synchronous Playback From All Recorderss, Monitor Wall Support, Surrounding Camera Mode, Cybersecured With Features Such As Digital Signing, General Data Protection Regulation ( Gdpr ) Compliance, Https & Ssl Base, Smart Web Client, Secured Firewall Configuration, Password Expiry, Non-Recoverable Password; Support Android & Ios Phones, Seamless Integration With Intgegrated Security Platform Which Provides Hsdk&Api For Further Integration With 3Rd Party Systems.The Vms Shall Be Complete System For Satisfactory Surveillance Operations With All Necessary Softwares, Licenses, Required Pc Hardware, Storage, Accessories Etc., Civil, Electrical Works & Peripheral Items, As Required As Per Specification, At Site Of Work Inline With The Engineer In Charge Instructions.S.Lifetime Validity , Supplying, Erecting, Testing & Commissioning Of Display Unit65resolution: 4K Ultra Hd ( 3840X2160 ) | Panel Technology Edge Led Blu 3840 X 2160 Brightness 350 Nitcontrast Ratio ( Typical ) 4000:1 Contrast Ratio ( Dynamic ) Mega Viewing Angle ( H / V ) 178 / 178 Response Time 8Ms ( Typ. ) Connectivity Input Rgb: Dvi-D Video: Hdmi 2.0 ( 2 ) Hdcp: Hdcp 2.2 Audio: Stereo Mini Jack, Dvi / Hdmi / Audio ( Common ) Usb: Usb 2.0 X 2Output Audio: Stereo Mini Jackexternal Controlrs232c ( In / Out ) Thru Stereo Jack, Rj45 Sensor Ir Powerpower Supply Ac 100 - 240 V~ ( + / - 10 % ) , 50 / 60 Hzhardware: Temperature Sensor, Pivot Display, Clock Battery ( 168Hrs Clock Keeping ) , Built In Speaker ( 10W 2Ch ) , Ip5x Rating, Wi-Fi / Bt Software: Auto Source Switching & Recovery, Lfd Home Ui, Button Lock, Hot Key Option, Plug&Play ( Initial Setting ) Smart Signage Platform Yesplug & Play Yeswi-Fi Yesspeaker Type Built In Speaker ( 10W + 10W ) Internal Playerprocessor Coretex A72 1.7Ghz Quad-Core Cpu On-Chip Cache Memory L1 Instruction Cache : 48Kb L1 Data Cache : 32Kb L2 Cache : 2Mbclock Speed 1.7Ghzmain Memory Interface 2.5Gb Lpddr4 1.5Ghz 64Bitgraphics Graphic Resolution : 1920 X 1080 Output Resolution : 3840 X 2160 ( Scale Up From Graphic Processing Result ) Storage 8Gb ( 3.88Gb Occupied By O / S, 4.12Gb Available ) Multimedia Video Decoder: Mpeg-1 / 2 / 4, H.263, H.264 / Avc, Uhd H.264 / Avc, Vc-1, Avs+, Hevc, Jpeg, Png, Vp8, Vp9 Audio Decoder: Ac3 , 28-Port Layer-2 Managed Gigabit Switch 1000M Sfp Interface 24 10G Sfp+ Interface 4 Auto Mdi / Mdix Yes ( Copper Ports ) Console Port Yes Switching Capacity 128 Gbps Max. Packet Forwarding Rate 95.24 Mpps Power Input 100 - 240 Vac Cpu Speed 400Mhz Dram Size 256Mb Flash Memory Size 32Mb Packet Buffer Size 448K Bits Fan 2 Dc Fan , Supplying And Plugging 3 M Fibre Patch Cord Lc-Sc Mm ( 50 ) Om3 Lszh Duplex Complete As Per Specification No. Wg-Coc / Fpc , Supply, Configuring Testing And Commissioning Of 10 Gbps Sfp Module For Level 2 Managable Switch Standards And Protocols Ieee 802.3Ae, Tcp / Ipwave Length 1310 Nm Power Supply 3.3V Fiber Type 9 / 125Um Single-Modemax. Cable Length 10 Km Data Rate 10 Gbps Port Type Lc Duplex Safety & Emission Fcc, Ce Environment Operating Temperature: 0–70 °C ( 32–158 °F ) Storage Temperature: -40–85 °C ( -40–185 °F ) , Supplying, Fixing, And Configuring Min. 580 Watt Redundant Power Supply System Erected In Provided Rack Complete. , Supplying, Fixing, And Configuring Broadband Adsl Dual Band Gigabit Wi-Fi 6 Router R With All Accessories Next-Gen Gigabit Wi-Fi 6 Speed—2402 Mbps On 5 Ghz And 574 Mbps On 2.4 Ghz Band Ensure Smoother Streaming And Faster Downloads. Connect More Devices—Ofdma Technology Increases Capacity By 4 Times To Enable Simultaneous Transmission To More Devices. Ultra-Low Latency—Enables More Responsive Gaming And Video Chatting. , Supplying, Installing, Testing & Commissioning Ac Split Type Variable Speed Inverter Technology Compressor, Room Air Conditioning Unit 2.0Tr Capacity Having Iseer Minimum A.C. Supply Having 1 No Of Air Handling Unit Hi-Wall / Floor Mounting Type Complete With Refrigerant R32 Having Copper Condenser, Minimum 2.5Pm Filter, Self Diagnosis Feature, Stabilizer Free Operation & Temperature Display On Indoor Unit, Clean Copper Pipe With Rohs Compliant Suitable For Refrigeran , Supplying & Erecting On Line Upspure Sine Wave Of 6 Kva Capacity 6Kva 1 / 1 With Inbuilt Isolation Transformer Along With 65Ah X 12 Nos Of Battery For 60Min Backup Along With Battery Rack + Connectors + Installation Warranty : 2 Yrs On Ups And Battery Both , Supply, Installation, Testing & Commissioning Ofworkstation As Per Following Specifications:Intel® Core™ Intel Core I7-13700, Os -Genuine Microsoft Windows® 1064-Bit, Ram -32Gb, Hard Drives -1Tgb 7200Rpm Sata3, 512Gb Ssd Video Adaptor - Integrated Intel Uhd Graphics 630 And Nvidia T1000, Network Connection - 1 Gbit / Sec Or Greater, Two ( 2 ) Pci-Express Expansion Slots 2 / 4 Usb, Cd / Dvd Rom, Usb Keyboard And Mouse, Associated Cables Etc Complete As Required , Data Storage Site All Installation Feettings, Infrastructure Furniture, Panneling, Partion Connections Alldevices Pvc Surface Modular, Computing Setup, Pvctrunking With Accessories / Port Patch Panel With Tool-Less Keystone Jacks, Spmcb Power Distribution And Protection , Supplying And Erecting 15M Hdmi Cord Low Voltage Grademinimum 4K Compliant To Be Laid In Provided Conduits With Male / Female 19 Pin Hdmi Connectors Complete. , Supplying And Erecting 15M Audio Video Cord Low Voltage Grade As Per Specificationwith Required 3Rca X 3Rca Connector Complete. , Supplying & Erecting Hdmi Extenderover Rj45 Ethernet Cable Cat 6, 60M / 200Ft Complete. , Supplying, Installing, Testing & Commissioning Of Dvi To Hdmi Convertor High-Speed Category, Supporting Full Hd 1080P, 2K And 4K Video Up To 30 Ft Length, 3D Having 24K Gold-Plated 19-Pin Type-A Connectors With High-Flex Cl3-Rated Jacket, Rohs Compliant Complete. , Automatic Number-Plate Recognition ( Anpr ) Software To Each Camera Multilingual Recognition Recognizeshigh Recognition Rate With Alphanumeric Number Plates Fast Recognition - The Full Reading Process , Supplying, Fixing, And Configuring Media Convertor 1000 Base-T To 1000 Base-Sx Sc Multi-Mode Media Converter ( 550M ) Complete. , Ip Horn Speaker Poe Powered Outdoor Weather Proof Ip Horn Speake Power Source Poe+ ( Ieee802.3At Class 4 ) , Poe ( Ieee802.3Af Class 3 ) Amplifier Rated Output 20W-25 W ( At Poe+ Powered ) Sensitivity 112 Db ( 1 W, 1 M ) Network I / F 100Base-Tx, Mdi / Mdi-X, Rj-45 Network Protocol Tcp / Ip, Udp, Http, Rtp, Rtsp, Arp, Icmp, Igmpv3, Ntp, Sip ( Rfc3261 ) Broadcasting Mode Pcmu / Pcma / G.722, Control Input 2 Channels, No-Voltage Make Contact Inputs, Open Voltage: 5 V Dc, Short-Circuit Current: 2 Ma Or Less, Removable Terminal Block ( 3 Pins ) Dust / Water Protection Ip66 , Ip Audio Gateway Embedded With Software Cpu 2.4 Ghz Intel Processor Ram 4Gb Ddr3l Storage 128Gb Ssdethernet Interface 1 X 10 / 100Mbps Rated Input Voltage 220-240V / 50Hz Endpoints 50 Interface Rj45 10Base-T / 100Base-Tx Installation Environment Indoor The Backbone Is Designed And Tested 24*7 In Extreme Industrial Environments For Rugged Usagethe Operating System Is Designed On Unix Platform To Work Seamlessly For Virus Free And Crash Free Usage , Announcement Console 7 Tft Lcd Full Colour Touch Panel Zone Selection, Announcement And Control Prority Annoucement Ethernet Interface Full Duplex Comunication Intercom Function High Quality Gooseneck Microphone And Builtin Loudspeaker ( 5W ) Support G.711, G.722, G.726, G.727, G.729, Mp3 Audio Codec And Aac+ Decoder Automatic Gain Control On Microphone Input , Supplying, Erecting, Testing & Commissioning 1 Tbexternal Ssdfast Nvme Technology For Simple, Quick Backup Password Enabled 256-Bit Aes Hardware Encryption Shock And Vibration Resistant — Drop Resistant Up To 6.5Ft ( 1.98M ) Capacity Connector Usb-C Compatibility Windows® 10+ Operating Systems Macos 11+ Sequential Read Performance 1050Mb / S Sequential Write Performance 1000Mb / S Usb 3.2 Gen 2 Warranty 5-Year Limited Warranty , Annual Fully Comprehensive Maintaenance Per Year Ofall Cameras, System And Fiber Networking Trughout The City
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Maharashtra View Result →
28.
Health and Family Welfare #9153826 Technical Bid
Supply Of Blood Bank Equipments , Rh / Slide Viewing Box , Rh / Slide Viewing Box: For Viewing Of Agglutinationon Slides Light Source : Cfl Power Supply : 230V Ac , Laminar Flow Bench Type , Laminar Flow Bench Type: Type : Horizontal Work Bench Size: 3 X 2 X 2 Ft Classification: Class 100 Main Filter : Minipleat Hepa, Particle Retention Size : Up To 0.3 Micron, Efficiency : 99.999% Pre Filter: Particle Retention Size : Up To 10 Micron, Efficiency: 98% Work Table: Ss 304 Cabinet:Gi Powdercoated Uv Light: Uv Lamp Of Suitable Length Illumination : Fl Lamp Of Suitable Length Switches : On / Off For Blower, Uv, Fl Pressure Gauge :Inclined Liquid Column Manometer Pet Cock : Ss Petcock For Air / Gas Front Door: Foldable Polycarbonate Sheet Wheels : Castor Wheels Supply : 220-230 Volts Ac , Gel Card Centrifuge With Incubator For Cross Matching , Gel Card Centrifuge:-1. Capacity A. Swing Out Rotor Should Accommodate 12 Or Morer Standard Gel Cards. 2. Max Speed Of The Centrifuge Should Be 1600 10 Rpm 3. Max Rcf Should Be 279 1 % G 4. Should Have Audio Visual Alarms For Imbalance, End Of Cycle And Any Other Errors 5. Should Have Single Hand Rotor Removal For Cleaning 6. Should Have Lcd Display With Touch Key Pad 7. Motor Should Be Brushless 8. Net Weight Should Be Less Than 20 Kg 9. Power Supply Should Be 220-240 Volts, 50 Hz, Single Phasegel Card Incubator:-1. Incubator Should Accommodate 12 Or More Gel Cards And 12 Or More Test Tubes Simultaneously 2. Should Maintain Temperature At 37°C 1°C 3. Time Limit Adjustable Up To 60 Minutes 4. Should Have Programs To Adjust Incubation Temperature & Time As Specified By Gel Card Supplier 5. Should Have Audio Visual Alarms For High / Low Temperature And End Of Cycle 6. Should Have Auto Pop-Up Card Mechanism For Card Removal, When Lid Is Opened 7. Should Have Lcd Display With Touch Key Pad 8. Power Supply: 220-240 Volts, 50 Hz, Single Phase , Digital Haemoglobin Meter With Disposable Cuvettes , Digital Haemoglobin Meter With Disposable Cuvettes:Principle : Absorbance Measurement Of Whole Blood At An Hb / Hb02 Isobestic Point; Dual Wavelengths ( 506 Nm A Nd 880 Nm ) For Hb Measurement And Turbidity Compensation Calibration : Factory Calibrated Against The Icsh Reference Method; Needs No Further Calibration Sa Mple Material : Capillary, Venous Or Arterial Whole Blood Measurement Range : 0 -25.6 G / Dl ( 0-256 G / L, 0-15.9 Mmol / L ) Results :3 Seconds Sample Volume Rv Lo ?L Dimensions: 140X70 X160 Mm Weight : 500 G With Batteries Installed Storage Temp : Analyzer: 0-50 °C Microcuvettes : 10-40 °C. For Unopened Vials, The Storage Temperature Ca N Be Extendeddown To -18 °C And Up To +50 °C For A Period Of Maximum 6 Weeks. Operating Temp : 10-40 °C Power : Ac Adapter Or 4 Aa Batteries Interface: For Printer Quality Control: Built-In Selftest, Optional : Liquid Controls Cuvettes :- Std Pack : 200 Nos , Blood Donor Couch ( Fully Automatic ) , Blood Donor Couch ( Fully Automatic ) :Technicaldata Height : 620 - 820 Mm Seat Width : 680 Mm Profile Length : 2010 Mm Back Rest Adjustment: O Degree - 54 Degree Leg Rest Adjustment: O Degree - 60 Degree Trendelenburgposition: -15 Degree Castor Wheels : Fouroo Mm Lockable Wheels Voltage: 230V ± 100% , Blood Transportation Box Portable , Blood Transportation Box Portable:Capacity: 25 L Cold Life: When Ambient Temperature Is Below +30°C, It Can Maintain +2 To +Sc For About 10 Hours If Kept In Closed Condition. , Diesel Generator 100 Kva , Supply Installation Testing And Commissioning Of 100 Kva Diesel Generator
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 4
29.
Drinking Water Supply and Sanitation #9084164 Technical Bid
Construction Of Mini Rural Water Supply Scheme Solar Motor Pump Complete Set In Block Giridih Panchayat Sindwariya Village Kurumdiha Svs Group Of Scheme Under Jjm D.W.S. Division, No 2 Giridih For The Year 2022-23 Svs 66 , Model-1Awith Source(Drilled T/W 125/115 Dia Mm, 60M Deep) , Tube Well , Drilling Portion , Construction For 115/125 Mm Dia Drilled Tube-Well For Drilling In All Kinds Of Soil Rock For Installation Of Hand Pump With D.T.H Rig Machine All Complete Including Supplying All Materials, Labours, Tools, Drilling, Rigs, Air Compressor And Equipments As Well As Fuel Lubricant For Making 125/115 Mm Dia Boring Etcand Cost Of Transporting Rig Machine And Other Vehicle Up To Site Workas Per Specification And Direction Of Engineer-In-Charge. , (A) Up To 30Mtr. Depth Bellow G.L. In Rural Areas , (B) Beyond 30Mtr.In Rural Areas , Providing All Equipments And Labour For Lowering 125Mm Dia Blue Upvc Casing Pipe As Casing For Protecting The Side From Falling During The Process Of Drilling All Complete Job Including Carriage Of Material To Work Site. , Supplying Labour Cement And Calcium Chloride Or Bentonite Solution And Equipments For Grouting To Casing Pipe All Complete Job Including Carriage Of Material To Work Site As Per Specification & Direction Of E/I , Supplying All Tools, Equipments And Labour And Doing Washing, Flushing And Development Of Drilled Tube Well To Give Clean And Clear Water All Complete As Per Direction E/I. , Supplying All Materials Labours And Equipment Including 125 Mm Dia Gi/Ci Cap 125 Mm Dia T/W Properly All Complete And Taking It Out As Per Specification & Direction Of E/I. (The Cap Will Be Property Of Department) , Civil Portion , Supplying All Tools, Equipment, Labours And Lowering 32 Mm Dia G.I. (Medium)Pipe In Dt In 3 Mtr. Length All Complete Job As Per Direction Of E/I. Including Carriage Of Materials. , Supplying All Tools, Labour For Fitting And Fixing Deep Well Cylinder With Necessary Connecting Rod All Complete Job As Per Specification & Direction Of E/I. , Supplying All Materials, Labours For Fitting And Fixing Of India Mark Ii Hand Pump With All Accessories All Job Complete As Per Direction Of E/I. Including Carriage Of Materials. , Supplying All Materials, Labours And Equipment For Constructing Pcc (1:2:4) Circular Platform Around Each Drilled Tube Well Including 12Mm Thick Cement Plaster (1:4) With Neat Cement Punning Over Exposed Surface As Per Unicef Design Etc. All Complete. Including Carriage Of Materials. , Supplying All Materials Labour And Equipment For Constructing Pcc (1:2:4) Drain As Per Unicef Design Etc. All Complete .Including Carriage Of Materials. , Add Extra Item For Supplying Tools, Labours And Materials For Painting, Numbering And Year For Construction Of T/Well And Taking Of Colour Photograph With Two Or Three Nearest Persons Including Platform, Drain, Soak Pit And Also Longitude & Latitude, Details Of T/W Such As Total Depth, Casing Depth, Static Water Level, Drawdown, Discharge, Strata Chart, Beneficiary Population Etc In Separate Sheet/Format All Complete As Per Direction Of E/I. , Cost Of Materials , Cost Of Standard I.S.I. Mark Deep Well Hand Pump For India Mark-Ii, I.S.I. 15500 (Part 2) / 2004 With Latest Revision Including 12Mm X 3 Meter Long 8 No. Connecting Rods Made Of Bright Bar Electro-Galvanized Fitted With Coupler & Normal Stand Assembly Recommended For Use With Cylinder Assembly Suitable For Bore Wellcasing Pipe. , Cost Of 32 Mm Dia Gi Pipe (Medium) 3 Mtrs Long Screwed At Both Ends With Seamless Socket As Per Is:1239(Part 1990). , Cost Of 125 Mm Dia Blue Upvc Casing Pipe As Per I.S.12818/2016 Cml No.- 5543459 , Solar Photovoltaic (Spv) Solar Submersible D.C. Water Motor Pump , Designing, Supplying, Installation, Testing & Commissioning With All Tools & Parts Of Following Solar Photovoltaic (Spv) Solar Submersible D.C. Water Motor Pump Suitable For Minimum 125Mm X 115Mm Bore Well As Per Mnre Guideline With Following Specifications & Accessories. , Spv Arrays Contains Specified No Of Same Capacity Type & Specification Modules Connected To Series Or Parallel To Obtained The Required Voltage & Current The Power Output Of Individual Pvmodules Should Be Minimum 200 Watt Peak. , I) The Spv Modules Should Be As Per Iec-61215 And Iec 61730 Part 1.0) , Ii) All External Parts Of Motor Pump Used In Submersible Pump Which Are In Contact Of Water Is Stainless Steel Grade 303 Or Higher As Required. , Iii) The Pv Modules Shouldbe Mounted On Metallic Structure Of Adequate Strength And Appropriate Design Which Can Withstand Load Of Modules & High Wind Pressure Up To 200Km/H. , Iv) The Module Mounting Structure Should Be Hot Dip Galvanized According To Is 4759. , V) To Enhance The Performance Of Spv Water Pumping System & Arrangement For Seasonal Tilt Angle Adjustment Should Be Provided , Vi) Necessary Arrangement Should Be Provided In Controller Automatic Start-Run-Stop Through Out The Day With Water Level Detection System. (As Per Mnre Specification) , Vii) Necessary Protection Such As Lightening Arrestor Etc. Should Be Provided To Protect The Controller & Spv , Viii) The Suction/Delivery Pipe Shall Be Upvc / H.D.P.E. Pipes Of Appropriate Size 60M Or More As Required Minimum Pressure Rating Of 8Kg/Sq Cm- Pe 100 Grade For Pump Up To 3Hp & 10 Kg/Sq Cm- Pe 100 Grade For 5 Hp. , Ix) All Cable Used Shall Be As Per Is 694. Suitable Size Of Cable Shall Be Used In Sufficient Length For Inter Connection Between The Spv Array To Spv Controller And Spv Controller To Solar Power Pump. Provision Of Cable Shall Be As Per Is 14536. , X) The Motor Pump Set Should Have A 5 Years Warranty. , Xi) Control Panel Suitable For Motor Pump With Arrangement Of Dry Run & Over Flow Protection Sensor, Float Switch & Rain Prevention Box. (As Per Mnre Specification) , Xii) The Spv Controller Must Have Ip-65 Protection Or Must Be Housed In Cabinet Having At Least Ip-65 Protection. , Xiii) The System Should Be As Per Mnre Guide Line & Eco-Friendly With Suitable Arrangement To Operate New Pump Manually. , Xiv) With Third Party Inspection Before Dispatch. , Xv) Fitting, Fixing & Mounting On Water Tank Steel Structure. , Xvi) Provision For Web Basedremote Monitoring Of The Pumps To Be Installed Must Be Made Through The Inbuilt Controllers . It Should Be Possible To Ascertain The Daily Water Output, The Power Generated By Pv Array ,The Up And Downtime Of The Pump During The Year, Number Of Days The Pump Was Unused Or Under Breakdown Repairs. , The Following Details Should Be Marked Indelibly On The Motor Pump Set , A) Name Of The Manufacturer Or Distinctive Logo. , B) Model Number. , C) Serial Number. , Solar Submersible Motor Pump (Spv Dc Type) , I) 1 Hp (Dc Pump) With 900 Wp Minimum Watt P.V. Panel As Mnre Pump Head Max Shut-Off Head Up To 120 Mtrs. For Higher Or Lower Head Or In Between Various Modules Output Could Be Decided On Prorates Basis. (As Per Latest Guide Line Of Mnre) , Carrying Out Recuperation/Yield Test For Ascertaining The Discharge Of Constructed Well/ Excavated Profile As Directed By The Iec. The Testout By The Drawing Down Water From The Well/ Profile Below Normal/Subsoil Water Level Up To Full Depth Rise Is Recorded The Normal Water Level/Subsoil Water Level In The Well / Profile As Well As Strainer/Level At Pump As Per Design Of W.S. Scheme Shall Be Recorded Prior To The Test Including Cost Of All Materials, Over Load , Labours Etc. Complete As Directed. , Supplying All Labours, Tools And Equipments For Dismantling Of Head & Water Tank Assembly And Taking Out 32 Mm Dia Old G.I. Pipe, Connecting Rod, Cylinder Assembly The Dismantled Components After Necessary Changing For Making The T/W In Good Condition With All Transportation Including Unused Taken Out Materials Back In Store All Complete Job As Per Direction Of E/I. , Provision Of Solar Night Lamp. , Construction Rcc Foundation For Steel Structurestaging& Solar Panel , Earth Work In Excavation In Foundation Trenches In Ordinary Soil And Disposal Of Excavated Earth As Obtained To A Distance Up To 50.0M ,Including All Lifts, Levelling ,Ramming The Foundation Trenches, Removing Roots Of Trees, Shrubs All Complete As Per Approved Design ,Building Specification And Direction Of E/I (Vide Classification Of Soil Item -B) , Providing Coarse Clean Sand In Filling In Foundation Trenches Or In Plinth Including Ramming And Watering In Layers Not Exceeding 150Mm Thick With All Leads And Lifts Including Cost Of All Materials ,Labour ,Royalty And Taxes All Complete As Per Building Specification And Direction Of E/I(Mode Of Measurement Compacted Volume) , Providing Designation 75 A One Brick Flat Soling Joints Filled With Local Sand Including Cost Of Watering Taxes Royalty All Complete As Per Building Specification And Direction Of E/I , Providing Pcc M-150 In Nominal Mix Of (1:2:4) In Foundationwith Approved Quality Of Stone Chips 20Mm To 6Mm Size Graded And Clean Coarse Sand Of F.M.2.5To 3 Including Screening Shuttering Mixing Cement Concrete In Mixer And Placing In Position Vibrating Striking Curing And Royalty All Complete As Per Building Specification And Direction Of E/I , Providing Rcc M-200 In Nominal Mix Of (1:1.5:3) In Columnswith Approved Quality Of Stone Chips 20Mm To 6Mm Size Graded And Clean Coarse Sand Of F.M.2.5To 3 Including Screening Shuttering Mixing Cement Concrete In Mixer And Placing In Position Vibrating Striking Curing And Royalty All Complete As Per Building Specification And Direction Of E/I. , (A)Foundation For Steel Structure Staging , Footing , Vertical Pedestal , Tie Beam , (B)Foundation For Solar Panel , Footing , Vertical Pedestal , Providing For Steel Reinforcement As Per Approved Design And Drawing Excluding Carriage Of T.S. Bar To Work Site Cutting, Bending With Annealed Wire With Cost Of Wire, Removal Of Rust Placing The Rods In Position All Complete As Per Building Specification And Direction Of E/I. , 10 Mm Dia , 12 Mm Dia , Carriage Of Construction Materials To Work Site Including Loading, Unloading & Stacking Etc. All Complete. , Cement10km Lead , Steel10km Lead , Stone Chips 11Km Lead , Sand36km Lead , Bricks 06Km Lead , Construction Ofgalvanized Tubular Steel Structure Staging For (4.5M) Hdpe Water Storage Tank& Solar Panel. , Providing Structural Steel Galvanised Tubular Hollow Section Work In Trusses, Other Similar Trussed Purlins And Members With All Bracing ,Gusset Plates Etc As Per Detailed Design And Drawing Or As Directed By Engineer- In-Charge ,Including Cutting Fabricating ,Hoisting , Erecting And Fixing In Position , Making Riveted/Bolted /Welded Connections And One Coat Of Anticorrosive Paint And Over It Two Coat Of All Oil Painting & For Structure(Plus) Providing And Applying Materials &Labour For Hot Dip Galvanizing Of Above Structure Including Transportation For Galvanizing Minimum Thickness 80Microns (Net Wt. Of Components To Be Galv) Preferably Tata Structural Section Etc Complete. , Providing Structural Steel Work In Trusses Other Similar Trussed Purlins And Members With Bracing Gusset Plates Etc As Per Detailed Design And Drawing Or As Directed By Engineer- In-Charge Including Cutting Fabricating Hoisting Erecting And Fixing In Position Making Reverted Bolted Welded Connections One Coat Of Anticorrosive Paint And Over It Two Coats Of Oil Painting Etc Complete. , Materials And Labour For Vinyl Painting Of Matter Given By Department In Different Color , Installation Of 2000 Liters Capacity Water Storage Tank , Providing And Fixing Hdpe Container Syntex Or Alike One Piecemolded Water Tank Made Out Of Low Density Polythyler Andbuilt Corrugation Including Of Delivery Up To Destination Hoisting And Fixing Of Accessories Such As Inlet, Outlet Overflow Of All Tanks Capacity 2000.00 Litres Capacity Water Storage Tank , Transportation Charge , Lifting Of 2000 Litrs Capacity Tank Up To 4.5M Height With Lifting Tools With Rope And Labour , Making Hole In Tank , Making Long Screw In G.I. Pipe Including Supplying And Fitting Jam Nuts And Extra Socket Etc. , Rising And Distribution Network With House Connection Up To 10 Nos. Including Platform & Stand Post , Earth Work In Excavation In Foundation Trenches In Hard Soil (Vide Classification Soil Item B) And Disposal Of Excavated Earth As Obtained To A Distance Up To 50 Mtr. Including All Lifts, Leveling, Ramming The Foundation Trenches, Removing Roots Of Trees, Shrubs All Complete As Per Approved Design, Specification And Direction Of E/I. , Dismantling Plain Cement Concrete Work Including Stacking Serviceable Materials In Countable Stacks Within 15 M Lead And Disposal Of Unserviceable Materials With All Leads All Complete. , Providing Pccm-200 With Nominal Mix Of (1:1.5:3) With Approved Quality Of Stone Chips 20 Mm To 6 Mm Size Graded And Clean Coarse Sand Of Fm 2.5 To 3.0 Including Screening, Shuttering, Mixing Cement Concrete In Mixer And Placing In Position, Vibrating, Sticking, Curing , Taxes And Royalty All Complete As Per Specification And Direction Of E/I. For Construction Of Road Cutting Portion. , Rising Main , Manufacture, Supply And Delivery Offollowing Nominal Dia Upvc Column Pipes Including Pvc Socket (Coupler), , 65Mm Dia -Density Of Pipe 1.38 To 1.43 Gm Per Cm3 Od:74.5 To 75.2Mm Wall Thickness End:9Mm To 10.7Mm, Barrel 9Mm To 10.7 Mm, Length: 3Mtrs.Rising Main , 50 Mm Dia -Density Of Pipe 1.38 To 1.43 Gm Per Cm3 Od:87.5 To 88.2Mm Wall Thickness End:9 .8 Mm To 11.9Mm, Barrel 7.3Mm To 9 Mm, Length: 3Mtrs. Delivery Pipe , Distribution Main , Providing And Supplying High Density Polyethylene Pipe (Hdpe Pipe) Of 20 Mm To 225 Mm Od And Pressure 6.0 Kg/Cm2 And 10 Kg/Cm2 Suitable For Water Supply Which Is Available In All Standard Conforming To Isi -- 4984/14151/12786/13488,Iso 4427 , Din-8074Materials Rates Are Ex-Factory Excluding Transportation, Taxes And Duties. Pe-80 , Pn- 10. , 63 Mm Hdpe Pipe , 50 Mm Hdpe Pipe , 32 Mm Hdpe Pipe- , 20 Mm Hdpe Pipe- , Providing And Fixing Gun Metal Gate Valvewith C I Wheel Of Approved Quality(Screwed End). , 65 Mm Dia , 50 Mm Dia . , Providing And Supplying High Density Polyethylene(Hdpe )Fittings Of 20 Mm To 225 Mm Od And Pressure 6.0 Kg/Cm2 And 10 Kg/Cm2 Suitable For Water Supply Which Is Available In All Standard Conforming To Isi -- 4984/14151/12786/13488,Iso 4427 , Din-8074Materials Rates Are Ex-Factory Excluding Transportation, Taxes And Duties. , Lowering, Laying And Jointing H. D. P. E./M. D.P. E. Pipes In Proper Position Including All Specials By Compression Fitting/Electro Fusion And Butt Fusion Jointing Procedure As Per Relevant Is Code Complete With All Materials For Jointing Procedure Like Electro Fusion Machine, Electric Heater/Butt Fusion Welding Machine With Hydraulic Jack, Top Loading Clamp Etc. And All Labours As Directed By Engineer In Charge As Per Is-7634 Part Ii. , For Rising , 65 Mm Hdpe Pipe , 50 Mm Hdpe Pipe , For Distribution , 65 Mm Hdpe Pipe , 50 Mm Hdpe Pipe , 32 Mm Hdpe Pipe , 20 Mm Hdpe Pipe , 15 Mm Dia Gi Pipe , Supplying All Materials , Labour And Tools For Fixing 15 Mm Dia G.I. Pipes With Red Lead And Yarn Of Following Nominal Bore With Screwed And Socketed Joints On Wall, Ceiling And Floor Including Supplying And Fitting Of Wall Hooks Or Pipe Clamps, Wooden Plugs, Cutting Pipes To Size And Threading Ends If Required Etc. All Complete As Per Specification And Direction Of Engineer-In-Charge. , Supplying And Fixing G.I. Fittings Of Approved Make All Complete As Per Specification And Direction Of E/I. , Elbow 15 Mm Dia. , Reducer Socket 20X15 Mm Dia. , Nipple 15 Mm Dia. , Plain Socket 15 Mm Dia. , Supplying And Fixing G.M. Ferrule Of Approved Make In Existing C.I./D.I. Main Including Drilling And Taping C.I./D.I. Main All Complete As Per Specification And Direction Of E/I. 3 Mm, 6 Mm 10 Mm Dm Ferrule Weight Not Less Than 425 Gram. , Providing And Fixing Gun Metal Full Way Valve Of Approved Quality, All Complete, As Per Specification And Direction Of E/I. , 65 Mm Dia Full Way Valve , 50 Mm Dia And Weight Not Less Than 1.5 Kg. , Providing And Fixing Of Male Ended C.I.Body Brass Spindle Valve And Seat Bib Cock Of Approved Quality With Extra Socketall Complete As Per Specification And Direction Of E/I. , 15 Dia And Weight Not Less Than 400 Gm , Constructing Masonry Chamber 30X30x50 Cm Inside, In Brick Work In Cement Mortar 1:4 (1 Cement :4 Coarse Sand) For Stop Cock, With C. I. Surface Box 100X100 X75 Mm (Inside) With Hinged Cover Fixed In Cement Concrete Slab 1:2:4 Mix (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size), I/C Necessary Excavation, Foundation Concrete 1:5:10 ( 1 Cement : 5 Fine Sand : 10 Graded Stone Aggregate 40Mm Nominal Size ) And Inside Plastering With Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) 12Mm Thick, Finished With A Floating Coat Of Neat Cement Complete As Per Standard Design.With Common Burnt Clay F.P.S.(Non Modular) Bricks Of Class Designation 7.5. , Full Way Valve Chamber , Supplying Materials , Labours And Equipments For Construction Of 0.90M X 0.90 M Size P.C.C. (1:2:4) Rectangular Platform With Stand Post In House Including 12 Mm Thick Cement Plaster In C.M. (1:4) With Neat Cement Punning Over Exposed Surfaceall Complete Job, As Per Approved Design, Specification And Direction Of E/I. , Providing Brick Masonry Chamber Ofinner Size 600 X 600 X 450 Mm Deep For Bore Well Protection Having 125 Mm Thick Wall And 75 Mm R.C.C Cover Including Cement Plaster Of Exposed Surface, Etc All Complete Job. , Earth Work In Back Filling The Trenches After Laying Different Types And Size Of Pipes With Earth Removed During Excavation Within Initial Lead And Lift As Per Specification And Direction Of Engineer-In-Charge. , Providing Fitting & Fixing 32 Mm To 50 Mm Service Hdpe Saddleall Complete Job, As Per Approved Design, Specification And Direction Of E/I. , Carriage Of Materials From Different Sources Or Departmental Stores To Work Site Including Loading, Transporting, Unloading And Stacking The Materials At Work Site Etc. All Complete Job. As Per Direction Of E/I. , Cement Lead 10 Km (Avg.) , Sand Lead 36 Km (Avg.) , Stone Chips Lead 11 Km (Avg.) , Steel Reinforcement Lead 10 Km (Avg.) , Bricks Lead 06 Km (Avg.) , Annual Operation & Maintenance Cost Based On Existing D/T Well With Solarmotor Pump For 5 Years , O & M Cost For 1St Year , O & M Cost For 2Nd Year , O & M Cost For 3Rd Year , O & M Cost For 4Th Year , O & M Cost For 5Th Year , Provision Of One No Sim Card & Its Recharging Cost For Rmc , 18% Gst , Labour Cess
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
30.
Drinking Water Supply and Sanitation #9084158 Technical Bid
Construction Of Mini Rural Water Supply Scheme Solar Motor Pump Complete Set In Block Dumri Panchayat Chachando Village Jobhi Svs Group Of Scheme Under Jjm D.W.S. Division, No 2 Giridih For The Year 2022-23 Svs 79 , Model-1B With Source (Drilled T/W 125/115Dia Mm, 60M Deep) , Tube Well , Drilling Portion , Construction For 115/125 Mm Dia Drilled Tube-Well For Drilling In All Kinds Of Soil Rock For Installation Of Hand Pump With D.T.H Rig Machine All Complete Including Supplying All Materials, Labours, Tools, Drilling, Rigs, Air Compressor And Equipments As Well As Fuel Lubricant For Making 125/115 Mm Dia Boring Etcand Cost Of Transporting Rig Machine And Other Vehicle Up To Site Workas Per Specification And Direction Of Engineer-In-Charge. , (A) Up To 30Mtr. Depth Bellow G.L. In Rural Areas , (B) Beyond 30Mtr.In Rural Areas , Providing All Equipments And Labour For Lowering 125Mm Dia Blue Upvc Casing Pipe As Casing For Protecting The Side From Falling During The Process Of Drilling All Complete Job Including Carriage Of Material To Work Site. , Supplying Labour Cement And Calcium Chloride Or Bentonite Solution And Equipments For Grouting To Casing Pipe All Complete Job Including Carriage Of Material To Work Site As Per Specification & Direction Of E/I , Supplying All Tools, Equipments And Labour And Doing Washing, Flushing And Development Of Drilled Tube Well To Give Clean And Clear Water All Complete As Per Direction E/I. , Supplying All Materials Labours And Equipment Including 125 Mm Dia Gi/Ci Cap 125 Mm Dia T/W Properly All Complete And Taking It Out As Per Specification & Direction Of E/I. (The Cap Will Be Property Of Department) , Civil Portion , Supplying All Tools, Equipment, Labours And Lowering 32 Mm Dia G.I. (Medium)Pipe In Dt In 3 Mtr. Length All Complete Job As Per Direction Of E/I. Including Carriage Of Materials. , Supplying All Tools, Labour For Fitting And Fixing Deep Well Cylinder With Necessary Connecting Rod All Complete Job As Per Specification & Direction Of E/I. , Supplying All Materials, Labours For Fitting And Fixing Of India Mark Ii Hand Pump With All Accessories All Job Complete As Per Direction Of E/I. Including Carriage Of Materials. , Supplying All Materials, Labours And Equipment For Constructing Pcc (1:2:4) Circular Platform Around Each Drilled Tube Well Including 12Mm Thick Cement Plaster (1:4) With Neat Cement Punning Over Exposed Surface As Per Unicef Design Etc. All Complete. Including Carriage Of Materials. , Supplying All Materials Labour And Equipment For Constructing Pcc (1:2:4) Drain As Per Unicef Design Etc. All Complete .Including Carriage Of Materials. , Add Extra Item For Supplying Tools, Labours And Materials For Painting, Numbering And Year For Construction Of T/Well And Taking Of Colour Photograph With Two Or Three Nearest Persons Including Platform, Drain, Soak Pit And Also Longitude & Latitude, Details Of T/W Such As Total Depth, Casing Depth, Static Water Level, Drawdown, Discharge, Strata Chart, Beneficiary Population Etc In Separate Sheet/Format All Complete As Per Direction Of E/I. , Cost Of Materials , Cost Of Standard I.S.I. Mark Deep Well Hand Pump For India Mark-Ii, I.S.I. 15500 (Part 2) / 2004 With Latest Revision Including 12Mm X 3 Meter Long 8 No. Connecting Rods Made Of Bright Bar Electro-Galvanized Fitted With Coupler & Normal Stand Assembly Recommended For Use With Cylinder Assembly Suitable For Bore Wellcasing Pipe. , Cost Of 32 Mm Dia Gi Pipe (Medium) 3 Mtrs Long Screwed At Both Ends With Seamless Socket As Per Is:1239(Part 1990). , Cost Of 125 Mm Dia Blue Upvc Casing Pipe As Per I.S.12818/2016 Cml No.- 5543459 , Rcc Foundation For Steel Structurestaging& Solar Panel , Earth Work In Excavation In Foundation Trenches In Ordinary Soil And Disposal Of Excavated Earth As Obtained To A Distance Up To 50.0M ,Including All Lifts, Levelling ,Ramming The Foundation Trenches, Removing Roots Of Trees, Shrubs All Complete As Per Approved Design ,Building Specification And Direction Of E/I(Vide Classification Of Soil Item -B) , Providing Coarse Clean Sand In Filling In Foundation Trenches Or In Plinth Including Ramming And Watering In Layers Not Exceeding 150Mm Thick With All Leads And Lifts Including Cost Of All Materials ,Labour ,Royalty And Taxes All Complete As Per Building Specification And Direction Of E/I , Back Filling , Providing Nominal Mix Pcc Of (1:2:4) In Foundationwith Approved Quality Of Stone Chips 20Mm To 6Mm Size Graded And Clean Coarse Sand Of F.M.2.5To 3 Including Screening Shuttering Mixing Cement Concrete In Mixer And Placing In Position Vibrating Striking Curing And Royalty All Complete As Per Building Specification And Direction Of E/I , Providing Rcc M-20 In Nominal Mix Of (1:1.5:3) In Columnswith Approved Quality Of Stone Chips 20Mm To 6Mm Size Graded And Clean Coarse Sand Of F.M.2.5To 3 Including Screening Shuttering Mixing Cement Concrete In Mixer And Placing In Position Vibrating Striking Curing And Royalty All Complete As Per Building Specification And Direction Of E/I. , (A)Foundation For Steel Structure Staging , Footing And Vertical Pedestal Raft , Column , Tie Beam , (B)Foundation For Solar Panel , Footing , Vertical Pedestal , Providing For Steel Reinforcement As Per Approved Design And Drawing Excluding Carriage Of T.S. Bar To Work Site Cutting, Bending With Annealed Wire With Cost Of Wire, Removal Of Rust Placing The Rods In Position All Complete As Per Building Specification And Direction Of E/I. , (A) Foundation For Steel Structure Staging , Carriage Of Materials From Different Sources Or Departmental Stores To Work Site Including Loading, Transporting, Unloading And Stacking The Materials At Work Site Etc. All Complete Job. As Per Direction Of E/I. , (Cement+Rod) Lead 10 Km (Avg.) , Sand Lead 36 Km (Avg.) , Stone Chips Lead 11 Km (Avg.) , Steel Reinforcement Lead 10 Km (Avg.) , Bricks Lead 06 Km (Avg.) , Galvanized Tubular Steel Structure Staging Forhdpe Water Storage Tank& Solar Panel , Providing Structural Steel Galvanisedsqure Pipe Section Work In Trusses, Other Similar Trussed Purlins And Members With All Bracing ,Gusset Plates Etc As Per Detailed Design And Drawing Or As Directed By Engineer- In-Charge ,Including Cutting Fabricating ,Hoisting , Erecting And Fixing In Position , Making Riveted/Bolted /Welded Connections And One Coat Of Anticorrosive Paint And Over It Two Coat Of All Oil Painting & For Structure(Plus) Providing And Applying Materials &Labour For Hot Dip Galvanizing Of Above Structure Including Transportation For Galvanizing Minimum Thickness 80Microns (Net Wt. Of Components To Be Galv) Preferably Tata Structural Section Etc Complete. , Hardware (L.S.) , Information Board For Iec , Providing Structural Steel Work In Trusses Other Similar Trussed Purlins And Members With Bracing Gusset Plates Etc As Per Detailed Design And Drawing Or As Directed By Engineer- In-Charge Including Cutting Fabricating Hoisting Erecting And Fixing In Position Making Reverted Bolted Welded Connections One Coat Of Anticorrosive Paint And Over It Two Coats Of Oil Painting Etc Complete , Installation Of 5000 Liters Capacity Water Storage Tank , Providing And Fixing Hdpe Container Syntex Or Alike One Piecemolded Water Tank Made Out Of Low Density Polythyler Andbuilt Corrugation Including Of Delivery Up To Destination Hoisting And Fixing Of Accessories Such As Inlet, Outlet Overflow Of All Tanks Capacity 5000.00 Litres Capacity Water Storage Tank , Transportation Charge , Lifting Of 5000 Litrs Capacity Tank Up To 4.00M Height With Lifting Tools With Rope And Labour , Making Hole In Tank , Making Long Screw In G.I. Pipe Including Supplying And Fitting Jam Nuts And Extra Socket Etc. , Rising And Distribution Network With House Connection Up To 20 Nos. Including Platform & Stand Post , Earth Work In Excavation In Foundation Trenches In Hard Soil (Vide Classification Soil Item B) And Disposal Of Excavated Earth As Obtained To A Distance Up To 50 Mtr. Including All Lifts, Leveling, Ramming The Foundation Trenches, Removing Roots Of Trees, Shrubs All Complete As Per Approved Design, Specification And Direction Of E/I. , Dismantling Plain Cement Concrete Work Including Stacking Serviceable Materials In Countable Stacks Within 15 M Lead And Disposal Of Unserviceable Materials With All Leads All Complete , Providing Pccm-200 With Nominal Mix Of (1:1.5:3) With Approved Quality Of Stone Chips 20 Mm To 6 Mm Size Graded And Clean Coarse Sand Of Fm 2.5 To 3.0 Including Screening, Shuttering, Mixing Cement Concrete In Mixer And Placing In Position, Vibrating, Sticking, Curing , Taxes And Royalty All Complete As Per Specification And Direction Of E/I. For Construction Of Road Cutting Portion , Rising Main , Manufacture, Supply And Delivery Offollowing Nominal Dia Upvc Column Pipes Including Pvc Socket (Coupler), , 65Mm Dia -Density Of Pipe 1.38 To 1.43 Gm Per Cm3 Od:74.5 To 75.2Mm Wall Thickness End:9Mm To 10.7Mm, Barrel 9Mm To 10.7 Mm, Length: 3Mtrs.Rising Main , 50 Mm Dia -Density Of Pipe 1.38 To 1.43 Gm Per Cm3 Od:87.5 To 88.2Mm Wall Thickness End:9 .8 Mm To 11.9Mm, Barrel 7.3Mm To 9 Mm, Length: 3Mtrs. Delivery Pipe , Distribution , Providing And Supplying High Density Polyethylene Pipe (Hdpe Pipe) Of 20 Mm To 225 Mm Od And Pressure 6.0 Kg/Cm2 And 10 Kg/Cm2 Suitable For Water Supply Which Is Available In All Standard Conforming To Isi -- 4984/14151/12786/13488,Iso 4427 , Din-8074Materials Rates Are Ex-Factory Excluding Transportation, Taxes And Duties. , 63 Mm Hdpe Pipe , 50 Mm Hdpe Pipe , 32 Mm Hdpe Pipe , 20 Mm Hdpe Pipe , Providing And Fixing Gun Metal Gate Valvewith C I Wheel Of Approved Quality(Screwed End). , 65 Mm Dia , 50Mm Dia , Providing And Supplying High Density Polyethylene(Hdpe )Fittings Of 20 Mm To 225 Mm Od And Pressure 6.0 Kg/Cm2 And 10 Kg/Cm2 Suitable For Water Supply Which Is Available In All Standard Conforming To Isi -- 4984/14151/12786/13488,Iso 4427 , Din-8074Materials Rates Are Ex-Factory Excluding Transportation, Taxes And Duties. , Lowering, Laying And Jointing H. D. P. E./M. D.P. E. Pipes In Proper Position Including All Specials By Compression Fitting/Electro Fusion And Butt Fusion Jointing Procedure As Per Relevant Is Code Complete With All Materials For Jointing Procedure Like Electro Fusion Machine, Electric Heater/Butt Fusion Welding Machine With Hydraulic Jack, Top Loading Clamp Etc. And All Labours As Directed By Engineer In Charge As Per Is-7634 Part Ii. , For Rising , 50 Mm Hdpe Pipe , 65 Mm Hdpe Pipe , Distribution , 65 Mm Hdpe Pipe , 50 Mm Hdpe Pipe , 32 Mm Hdpe Pipe , 20 Mm Hdpe Pipe , Providing 15 Mm Dia. G.I. Pipe Tata Or Equivalent Make As Per Is 1239 (Part 1/2004) Isi Mark /Medium Quality In Stand Post. , Supplying All Materials , Labour And Tools For Fixing 15 Mm Dia G.I. Pipes With Red Lead And Yarn Of Following Nominal Bore With Screwed And Socketed Joints On Wall, Ceiling And Floor Including Supplying And Fitting Of Wall Hooks Or Pipe Clamps, Wooden Plugs, Cutting Pipes To Size And Threading Ends If Required Etc. All Complete As Per Specification And Direction Of Engineer-In-Charge. , Supplying And Fixing G.I. Fittings Of Approved Make All Complete As Per Specification And Direction Of E/I. , Elbow 15 Mm Dia. , Reducer Socket 20X15 Mm Dia. , Nipple 15 Mm Dia. , Plain Socket 15 Mm Dia. , Supplying And Fixing G.M. Ferrule Of Approved Make In Existing C.I./D.I. Main Including Drilling And Taping C.I./D.I. Main All Complete As Per Specification And Direction Of E/I. 3 Mm, 6 Mm 10 Mm Dm Ferrule Weight Not Less Than 425 Gram. , Providing And Fixing Gun Metal Full Way Valve Of Approved Quality, All Complete, As Per Specification And Direction Of E/I. , 65 Mm Dia Full Way Valve , 50 Mm Dia And Weight Not Less Than 1.5 Kg. , Providing And Fixing Of Male Ended C.I.Body Brass Spindle Valve And Seat Bib Cock Of Approved Quality With Extra Socketall Complete As Per Specification And Direction Of E/I. , 15 Dia And Weight Not Less Than 400 Gm , Constructing Masonry Chamber 30X30x50 Cm Inside, In Brick Work In Cement Mortar 1:4 (1 Cement :4 Coarse Sand) For Stop Cock, With C. I. Surface Box 100X100 X75 Mm (Inside) With Hinged Cover Fixed In Cement Concrete Slab 1:2:4 Mix (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size), I/C Necessary Excavation, Foundation Concrete 1:5:10 ( 1 Cement : 5 Fine Sand : 10 Graded Stone Aggregate 40Mm Nominal Size ) And Inside Plastering With Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) 12Mm Thick, Finished With A Floating Coat Of Neat Cement Complete As Per Standard Design.With Common Burnt Clay F.P.S.(Non Modular) Bricks Of Class Designation 7.5. Full Way Valve Chamber , Supplying Materials , Labours And Equipments For Construction Of 0.90M X 0.90 M Size P.C.C. (1:2:4) Rectangular Platform With Stand Post In House Including 12 Mm Thick Cement Plaster In C.M. (1:4) With Neat Cement Punning Over Exposed Surfaceall Complete Job, As Per Approved Design, Specification And Direction Of E/I. , Providing Brick Masonry Chamber Ofinner Size 600 X 600 X 450 Mm Deep For Bore Well Protection Having 125 Mm Thick Wall And 75 Mm R.C.C Cover Including Cement Plaster Of Exposed Surface, Etc All Complete Job , Earth Work In Back Filling The Trenches After Laying Different Types And Size Of Pipes With Earth Removed During Excavation Within Initial Lead And Lift As Per Specification And Direction Of Engineer-In-Charge. , Providing Fitting & Fixing 32 Mm To 50 Mm Service Hdpe Saddleall Complete Job, As Per Approved Design, Specification And Direction Of E/I. , Carriage Of Materials From Different Sources Or Departmental Stores To Work Site Including Loading, Transporting, Unloading And Stacking The Materials At Work Site Etc. All Complete Job. As Per Direction Of E/I. , Cement Lead 10 Km (Avg.) , Sand Lead 36 Km (Avg.) , Stone Chips Lead 11 Km (Avg.) , Steel Reinforcement Lead 10 Km (Avg.) , Bricks Lead 06 Km (Avg.) , Solar Photovoltaic (Spv) Solar Submersible D.C. Water Motor Pump , Designing, Supplying, Installation, Testing & Commissioning With All Tools & Parts Of Following Solar Photovoltaic (Spv) Solar Submersible D.C. Water Motor Pump Suitable For Minimum 125Mm X 115Mm Bore Well As Per Mnre Guideline With Following Specifications & Accessories. , Spv Arrays Contains Specified No Of Same Capacity Type & Specification Modules Connected To Series Or Parallel To Obtained The Required Voltage & Current The Power Output Of Individual Pvmodules Should Be Minimum 200 Watt Peak. , I) The Spv Modules Should Be As Per Iec-61215 And Iec 61730 Part 1.0) , Ii) All External Parts Of Motor Pump Used In Submersible Pump Which Are In Contact Of Water Is Stainless Steel Grade 303 Or Higher As Required. , Iii) The Pv Modules Shouldbe Mounted On Metallic Structure Of Adequate Strength And Appropriate Design Which Can Withstand Load Of Modules & High Wind Pressure Up To 200Km/H. , Iv) The Module Mounting Structure Should Be Hot Dip Galvanized According To Is 4759. , V) To Enhance The Performance Of Spv Water Pumping System & Arrangement For Seasonal Tilt Angle Adjustment Should Be Provided , Vi) Necessary Arrangement Should Be Provided In Controller Automatic Start-Run-Stop Through Out The Day With Water Level Detection System. (As Per Mnre Specification) , Vii) Necessary Protection Such As Lightening Arrestor Etc. Should Be Provided To Protect The Controller & Spv , Viii) The Suction/Delivery Pipe Shall Be Upvc / H.D.P.E. Pipes Of Appropriate Size 60M Or More As Required Minimum Pressure Rating Of 8Kg/Sq Cm- Pe 100 Grade For Pump Up To 3Hp & 10 Kg/Sq Cm- Pe 100 Grade For 5 Hp. , Ix) All Cable Used Shall Be As Per Is 694. Suitable Size Of Cable Shall Be Used In Sufficient Length For Inter Connection Between The Spv Array To Spv Controller And Spv Controller To Solar Power Pump. Provision Of Cable Shall Be As Per Is 14536. , X) The Motor Pump Set Should Have A 5 Years Warranty. , Xi) Control Panel Suitable For Motor Pump With Arrangement Of Dry Run & Over Flow Protection Sensor, Float Switch & Rain Prevention Box. (As Per Mnre Specification) , Xii) The Spv Controller Must Have Ip-65 Protection Or Must Be Housed In Cabinet Having At Least Ip-65 Protection. , Xiii) The System Should Be As Per Mnre Guide Line & Eco-Friendly With Suitable Arrangement To Operate New Pump Manually. , Xiv) With Third Party Inspection Before Dispatch. , Xv) Provision For Web Basedremote Monitoring Of The Pumps To Be Installed Must Be Made Through The Inbuilt Controllers . It Should Be Possible To Ascertain The Daily Water Output, The Power Generated By Pv Array ,The Up And Downtime Of The Pump During The Year, Number Of Days The Pump Was Unused Or Under Breakdown Repairs. , The Following Details Should Be Marked Indelibly On The Motor Pump Set , A) Name Of The Manufacturer Or Distinctive Logo. , B) Model Number. , C) Serial Number. , Solar Submersible Motor Pump (Spv Dc Type) , I) 1 Hp (Dc Pump) With 900 Wp Minimum Watt P.V. Panel As Mnre Pump Head Max Shut-Off Head Up To 120 Mtrs. For Higher Or Lower Head Or In Between Various Modules Output Could Be Decided On Prorates Basis. (As Per Latest Guide Line Of Mnre) , Carrying Out Recuperation/Yield Test For Ascertaining The Discharge Of Constructed Well/ Excavated Profile As Directed By The Iec. The Testout By The Drawing Down Water From The Well/ Profile Below Normal/Subsoil Water Level Up To Full Depth Rise Is Recorded The Normal Water Level/Subsoil Water Level In The Well / Profile As Well As Strainer/Level At Pump As Per Design Of W.S. Scheme Shall Be Recorded Prior To The Test Including Cost Of All Materials, Over Load , Labours Etc. Complete As Directed. , Supplying All Labours, Tools And Equipments For Dismantling Of Head & Water Tank Assembly And Taking Out 32 Mm Dia Old G.I. Pipe, Connecting Rod, Cylinder Assembly The Dismantled Components After Necessary Changing For Making The T/W In Good Condition With All Transportation Including Unused Taken Out Materials Back In Store All Complete Job As Per Direction Of E/I. (As Per Model Estimate Of Solar Energy Based Mini Wss. Ts Done By Se, Ranchi Circle & Circle Gumla Dt. 21.05.2019) , Provision Of Solar Night Lamp. , Galvanised Chain-Line Mess Fencing Around Solar Panel Where Bore Well Is Away From Tower , Making 30 Cm (12) Dia Bore Up To 4M Below Ground With Hand Auger Of Approved Quality In Ordinary Soil (Vide Classification Of Soil Item-A) True To Plum And Without Eccentricity In Any Stage Of Operation And Disposal Of The Exacavated Earth Up To 50M Lead Including All Lifts All Complete As Per Approved Design And Direction Of E/I. , Providing Pcc M-150 In Nominal Mix Of (1:2:4) In Foundationwith Approved Quality Of Stone Chips 20Mm To 6Mm Size Graded And Clean Coarse Sand Of F.M.2.5 To 3 Including Screening Shuttering, Mixing Cement Concrete In Mixer And Placing In Position, Vibrating, Curing, Taxes And Royalty All Complete As Per Building Specification Direction Of E/I. , Labour Cost Of Fitting And Fixing Galvanised Chain-Link Mess Up Height Of 2 M Including Cost Of Staples (But Excluding The Cost Of Cement Concete Angle Iron Posts, Its Cutting And Making Holes, Nuts And Bolts) All Complete As Per Specification And Direction Of E/I. , Drilling 6Mm Dia Holes In M.S Angle Iron For Fixing Of Stables Etc. As Per Building Specification And Direction Of E/I. , Labour Cost Cutting Of M.S Angle Iron Posts To Required Length, One End Splitted As Fish Tailed In A Length Of 150Mm Complete As Per Building Sepcification And Direction Of E/I. , Supplying, Fitting And Fixing Straining Bolts With Nut Size 22Cm*10Mm Dia Tighten The Barbed Wire With Corner Post Complete As Per Building Specification And Direction Of E/I. , Supplying, Fitting And Fixing Galvanised Chain -Link Mess Having 3Mm Thick Wire Cell Type 40 X 40 Mm Fitted On M.S. Angle Frame With Two Diagonals Having 25X25x5mm Size Angle Including Cost Of Fabrication, Providing Necessary Bocking Arrangement With Haskal And Domny Duly Fixed In Angle Post, Applying A Priming Red Lead Paint Over Steel Work, Taxes Excluding The Cost Of Galvanised Chain-Link Mess All Complete. , Cost Of Galvanised Chain-Link Mess Having 3 Mm Thick Wire Cell Type 40X40 Mm Not Less Than 3.1 Kg/Sqm , Cost Of 50 X 50 X 6 Mm M.S Angle , Carriage Of Materials From Different Sources Or Departmental Stores To Work Site Including Loading, Transporting, Unloading And Stacking The Materials At Work Site Etc. All Complete Job. As Per Direction Of E/I. , Cement Lead 10 Km (Avg.) , Sand Lead 36 Km (Avg.) , Stone Chips Lead 11 Km (Avg.) , Steel Reinforcement Lead 10 Km (Avg.) , Annual Operation & Maintenance Cost Based On Existing D/T Well With Solarmotor Pump For 5 Years , O & M Cost For 1St Year (Excluding Repair Charges) , O & M Cost For 2Nd Year With Annual Repair Charges , O & M Cost For 3Rd Year , O & M Cost For 4Th Year , O & M Cost For 5Th Year , Provision Of One No Sim Card & Its Recharging Cost For Rmc , 18% Gst , Labour Cess
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 4
31.
Drinking Water Supply and Sanitation #9062077 Technical Bid
Construction Of Solar Based Mrwss Svs In Pirtand Block, Comprising Of Suitable R.C.C Framed Structure Esr Distribution Lines, Source ( As Required ) And Fhtc All Complete Under Drinking Water Sanitation Division No 2 Giridih Cluster No 13 , Model-1Awith Source ( Drilled T / W 125 / 115 Dia Mm, 60M Deep ) , Tube Well , Drilling Portion , Construction For 115 / 125 Mm Dia Drilled Tube-Well For Drilling In All Kinds Of Soil Rock For Installation Of Hand Pump With D.T.H Rig Machine All Complete Including Supplying All Materials, Labours, Tools, Drilling, Rigs, Air Compressor And Equipments As Well As Fuel Lubricant For Making 125 / 115 Mm Dia Boring Etcand Cost Of Transporting Rig Machine And Other Vehicle Up To Site Workas Per Specification And Direction Of Engineer-In-Charge. , ( A ) Up To 30Mtr. Depth Bellow G.L. In Rural Areas , ( B ) Beyond 30Mtr.In Rural Areas , Providing All Equipments And Labour For Lowering 125Mm Dia Blue Upvc Casing Pipe As Casing For Protecting The Side From Falling During The Process Of Drilling All Complete Job Including Carriage Of Material To Work Site. , Supplying Labour Cement And Calcium Chloride Or Bentonite Solution And Equipments For Grouting To Casing Pipe All Complete Job Including Carriage Of Material To Work Site As Per Specification & Direction Of E / I , Supplying All Tools, Equipments And Labour And Doing Washing, Flushing And Development Of Drilled Tube Well To Give Clean And Clear Water All Complete As Per Direction E / I. , Supplying All Materials Labours And Equipment Including 125 Mm Dia Gi / Ci Cap 125 Mm Dia T / W Properly All Complete And Taking It Out As Per Specification & Direction Of E / I. ( The Cap Will Be Property Of Department ) , Civil Portion , Supplying All Tools, Equipment, Labours And Lowering 32 Mm Dia G.I. ( Medium ) Pipe In Dt In 3 Mtr. Length All Complete Job As Per Direction Of E / I. Including Carriage Of Materials. , Supplying All Tools, Labour For Fitting And Fixing Deep Well Cylinder With Necessary Connecting Rod All Complete Job As Per Specification & Direction Of E / I. , Supplying All Materials, Labours For Fitting And Fixing Of India Mark Ii Hand Pump With All Accessories All Job Complete As Per Direction Of E / I. Including Carriage Of Materials. , Supplying All Materials, Labours And Equipment For Constructing Pcc ( 1:2:4 ) Circular Platform Around Each Drilled Tube Well Including 12Mm Thick Cement Plaster ( 1:4 ) With Neat Cement Punning Over Exposed Surface As Per Unicef Design Etc. All Complete. Including Carriage Of Materials. , Supplying All Materials Labour And Equipment For Constructing Pcc ( 1:2:4 ) Drain As Per Unicef Design Etc. All Complete .Including Carriage Of Materials. , Add Extra Item For Supplying Tools, Labours And Materials For Painting, Numbering And Year For Construction Of T / Well And Taking Of Colour Photograph With Two Or Three Nearest Persons Including Platform, Drain, Soak Pit And Also Longitude & Latitude, Details Of T / W Such As Total Depth, Casing Depth, Static Water Level, Drawdown, Discharge, Strata Chart, Beneficiary Population Etc In Separate Sheet / Format All Complete As Per Direction Of E / I. , Cost Of Materials , Cost Of Standard I.S.I. Mark Deep Well Hand Pump For India Mark-Ii, I.S.I. 15500 ( Part 2 ) / 2004 With Latest Revision Including 12Mm X 3 Meter Long 8 No. Connecting Rods Made Of Bright Bar Electro-Galvanized Fitted With Coupler & Normal Stand Assembly Recommended For Use With Cylinder Assembly Suitable For Bore Wellcasing Pipe. , Cost Of 32 Mm Dia Gi Pipe ( Medium ) 3 Mtrs Long Screwed At Both Ends With Seamless Socket As Per Is:1239 ( Part 1990 ) . , Cost Of 125 Mm Dia Blue Upvc Casing Pipe As Per I.S.12818 / 2016 Cml No.- 5543459 , Solar Photovoltaic ( Spv ) Solar Submersible D.C. Water Motor Pump , Designing, Supplying, Installation, Testing & Commissioning With All Tools & Parts Of Following Solar Photovoltaic ( Spv ) Solar Submersible D.C. Water Motor Pump Suitable For Minimum 125Mm X 115Mm Bore Well As Per Mnre Guideline With Following Specifications & Accessories. , Spv Arrays Contains Specified No Of Same Capacity Type & Specification Modules Connected To Series Or Parallel To Obtained The Required Voltage & Current The Power Output Of Individual Pvmodules Should Be Minimum 200 Watt Peak. , I ) The Spv Modules Should Be As Per Iec-61215 And Iec 61730 Part 1.0 ) , Ii ) All External Parts Of Motor Pump Used In Submersible Pump Which Are In Contact Of Water Is Stainless Steel Grade 303 Or Higher As Required. , Iii ) The Pv Modules Shouldbe Mounted On Metallic Structure Of Adequate Strength And Appropriate Design Which Can Withstand Load Of Modules & High Wind Pressure Up To 200Km / H. , Iv ) The Module Mounting Structure Should Be Hot Dip Galvanized According To Is 4759. , V ) To Enhance The Performance Of Spv Water Pumping System & Arrangement For Seasonal Tilt Angle Adjustment Should Be Provided , Vi ) Necessary Arrangement Should Be Provided In Controller Automatic Start-Run-Stop Through Out The Day With Water Level Detection System. ( As Per Mnre Specification ) , Vii ) Necessary Protection Such As Lightening Arrestor Etc. Should Be Provided To Protect The Controller & Spv , Viii ) The Suction / Delivery Pipe Shall Be Upvc / H.D.P.E. Pipes Of Appropriate Size 60M Or More As Required Minimum Pressure Rating Of 8Kg / Sq Cm- Pe 100 Grade For Pump Up To 3Hp & 10 Kg / Sq Cm- Pe 100 Grade For 5 Hp. , Ix ) All Cable Used Shall Be As Per Is 694. Suitable Size Of Cable Shall Be Used In Sufficient Length For Inter Connection Between The Spv Array To Spv Controller And Spv Controller To Solar Power Pump. Provision Of Cable Shall Be As Per Is 14536. , X ) The Motor Pump Set Should Have A 5 Years Warranty. , Xi ) Control Panel Suitable For Motor Pump With Arrangement Of Dry Run & Over Flow Protection Sensor, Float Switch & Rain Prevention Box. ( As Per Mnre Specification ) , Xii ) The Spv Controller Must Have Ip-65 Protection Or Must Be Housed In Cabinet Having At Least Ip-65 Protection. , Xiii ) The System Should Be As Per Mnre Guide Line & Eco-Friendly With Suitable Arrangement To Operate New Pump Manually. , Xiv ) With Third Party Inspection Before Dispatch. , Xv ) Fitting, Fixing & Mounting On Water Tank Steel Structure. , Xvi ) Provision For Web Basedremote Monitoring Of The Pumps To Be Installed Must Be Made Through The Inbuilt Controllers . It Should Be Possible To Ascertain The Daily Water Output, The Power Generated By Pv Array , The Up And Downtime Of The Pump During The Year, Number Of Days The Pump Was Unused Or Under Breakdown Repairs. , The Following Details Should Be Marked Indelibly On The Motor Pump Set , A ) Name Of The Manufacturer Or Distinctive Logo. , B ) Model Number. , C ) Serial Number. , Solar Submersible Motor Pump ( Spv Dc Type ) , I ) 1 Hp ( Dc Pump ) With 900 Wp Minimum Watt P.V. Panel As Mnre Pump Head Max Shut-Off Head Up To 120 Mtrs. For Higher Or Lower Head Or In Between Various Modules Output Could Be Decided On Prorates Basis. ( As Per Latest Guide Line Of Mnre ) , Carrying Out Recuperation / Yield Test For Ascertaining The Discharge Of Constructed Well / Excavated Profile As Directed By The Iec. The Testout By The Drawing Down Water From The Well / Profile Below Normal / Subsoil Water Level Up To Full Depth Rise Is Recorded The Normal Water Level / Subsoil Water Level In The Well / Profile As Well As Strainer / Level At Pump As Per Design Of W.S. Scheme Shall Be Recorded Prior To The Test Including Cost Of All Materials, Over Load , Labours Etc. Complete As Directed. , Supplying All Labours, Tools And Equipments For Dismantling Of Head & Water Tank Assembly And Taking Out 32 Mm Dia Old G.I. Pipe, Connecting Rod, Cylinder Assembly The Dismantled Components After Necessary Changing For Making The T / W In Good Condition With All Transportation Including Unused Taken Out Materials Back In Store All Complete Job As Per Direction Of E / I. , Provision Of Solar Night Lamp. , Construction Rcc Foundation For Steel Structurestaging& Solar Panel , Earth Work In Excavation In Foundation Trenches In Ordinary Soil And Disposal Of Excavated Earth As Obtained To A Distance Up To 50.0M , Including All Lifts, Levelling , Ramming The Foundation Trenches, Removing Roots Of Trees, Shrubs All Complete As Per Approved Design , Building Specification And Direction Of E / I ( Vide Classification Of Soil Item -B ) , Providing Coarse Clean Sand In Filling In Foundation Trenches Or In Plinth Including Ramming And Watering In Layers Not Exceeding 150Mm Thick With All Leads And Lifts Including Cost Of All Materials , Labour , Royalty And Taxes All Complete As Per Building Specification And Direction Of E / I ( Mode Of Measurement Compacted Volume ) , Providing Designation 75 A One Brick Flat Soling Joints Filled With Local Sand Including Cost Of Watering Taxes Royalty All Complete As Per Building Specification And Direction Of E / I , Providing Pcc M-150 In Nominal Mix Of ( 1:2:4 ) In Foundationwith Approved Quality Of Stone Chips 20Mm To 6Mm Size Graded And Clean Coarse Sand Of F.M.2.5To 3 Including Screening Shuttering Mixing Cement Concrete In Mixer And Placing In Position Vibrating Striking Curing And Royalty All Complete As Per Building Specification And Direction Of E / I , Providing Rcc M-200 In Nominal Mix Of ( 1:1.5:3 ) In Columnswith Approved Quality Of Stone Chips 20Mm To 6Mm Size Graded And Clean Coarse Sand Of F.M.2.5To 3 Including Screening Shuttering Mixing Cement Concrete In Mixer And Placing In Position Vibrating Striking Curing And Royalty All Complete As Per Building Specification And Direction Of E / I. , ( A ) Foundation For Steel Structure Staging , Footing , Vertical Pedestal , Tie Beam , ( B ) Foundation For Solar Panel , Footing , Vertical Pedestal , Providing For Steel Reinforcement As Per Approved Design And Drawing Excluding Carriage Of T.S. Bar To Work Site Cutting, Bending With Annealed Wire With Cost Of Wire, Removal Of Rust Placing The Rods In Position All Complete As Per Building Specification And Direction Of E / I. , 10 Mm Dia , 12 Mm Dia , Carriage Of Construction Materials To Work Site Including Loading, Unloading & Stacking Etc. All Complete. , Cement10km Lead , Steel10km Lead , Stone Chips 11Km Lead , Sand36km Lead , Bricks 06Km Lead , Construction Ofgalvanized Tubular Steel Structure Staging For ( 4.5M ) Hdpe Water Storage Tank& Solar Panel. , Providing Structural Steel Galvanised Tubular Hollow Section Work In Trusses, Other Similar Trussed Purlins And Members With All Bracing , Gusset Plates Etc As Per Detailed Design And Drawing Or As Directed By Engineer- In-Charge , Including Cutting Fabricating , Hoisting , Erecting And Fixing In Position , Making Riveted / Bolted / Welded Connections And One Coat Of Anticorrosive Paint And Over It Two Coat Of All Oil Painting & For Structure ( Plus ) Providing And Applying Materials &Labour For Hot Dip Galvanizing Of Above Structure Including Transportation For Galvanizing Minimum Thickness 80Microns ( Net Wt. Of Components To Be Galv ) Preferably Tata Structural Section Etc Complete. , Providing Structural Steel Work In Trusses Other Similar Trussed Purlins And Members With Bracing Gusset Plates Etc As Per Detailed Design And Drawing Or As Directed By Engineer- In-Charge Including Cutting Fabricating Hoisting Erecting And Fixing In Position Making Reverted Bolted Welded Connections One Coat Of Anticorrosive Paint And Over It Two Coats Of Oil Painting Etc Complete. , Materials And Labour For Vinyl Painting Of Matter Given By Department In Different Color , Installation Of 2000 Liters Capacity Water Storage Tank , Providing And Fixing Hdpe Container Syntex Or Alike One Piecemolded Water Tank Made Out Of Low Density Polythyler Andbuilt Corrugation Including Of Delivery Up To Destination Hoisting And Fixing Of Accessories Such As Inlet, Outlet Overflow Of All Tanks Capacity 2000.00 Litres Capacity Water Storage Tank , Transportation Charge , Lifting Of 2000 Litrs Capacity Tank Up To 4.5M Height With Lifting Tools With Rope And Labour , Making Hole In Tank , Making Long Screw In G.I. Pipe Including Supplying And Fitting Jam Nuts And Extra Socket Etc. , Rising And Distribution Network With House Connection Up To 10 Nos. Including Platform & Stand Post , Earth Work In Excavation In Foundation Trenches In Hard Soil ( Vide Classification Soil Item B ) And Disposal Of Excavated Earth As Obtained To A Distance Up To 50 Mtr. Including All Lifts, Leveling, Ramming The Foundation Trenches, Removing Roots Of Trees, Shrubs All Complete As Per Approved Design, Specification And Direction Of E / I. , Dismantling Plain Cement Concrete Work Including Stacking Serviceable Materials In Countable Stacks Within 15 M Lead And Disposal Of Unserviceable Materials With All Leads All Complete. , Providing Pccm-200 With Nominal Mix Of ( 1:1.5:3 ) With Approved Quality Of Stone Chips 20 Mm To 6 Mm Size Graded And Clean Coarse Sand Of Fm 2.5 To 3.0 Including Screening, Shuttering, Mixing Cement Concrete In Mixer And Placing In Position, Vibrating, Sticking, Curing , Taxes And Royalty All Complete As Per Specification And Direction Of E / I. For Construction Of Road Cutting Portion. , Rising Main , Manufacture, Supply And Delivery Offollowing Nominal Dia Upvc Column Pipes Including Pvc Socket ( Coupler ) , , 65Mm Dia -Density Of Pipe 1.38 To 1.43 Gm Per Cm3 Od:74.5 To 75.2Mm Wall Thickness End:9Mm To 10.7Mm, Barrel 9Mm To 10.7 Mm, Length: 3Mtrs.Rising Main , 50 Mm Dia -Density Of Pipe 1.38 To 1.43 Gm Per Cm3 Od:87.5 To 88.2Mm Wall Thickness End:9 .8 Mm To 11.9Mm, Barrel 7.3Mm To 9 Mm, Length: 3Mtrs. Delivery Pipe , Distribution Main , Providing And Supplying High Density Polyethylene Pipe ( Hdpe Pipe ) Of 20 Mm To 225 Mm Od And Pressure 6.0 Kg / Cm2 And 10 Kg / Cm2 Suitable For Water Supply Which Is Available In All Standard Conforming To Isi -- 4984 / 14151 / 12786 / 13488, Iso 4427 , Din-8074Materials Rates Are Ex-Factory Excluding Transportation, Taxes And Duties. Pe-80 , Pn- 10. , 63 Mm Hdpe Pipe , 50 Mm Hdpe Pipe , 32 Mm Hdpe Pipe- , 20 Mm Hdpe Pipe- , Providing And Fixing Gun Metal Gate Valvewith C I Wheel Of Approved Quality ( Screwed End ) . , 65 Mm Dia , 50 Mm Dia . , Providing And Supplying High Density Polyethylene ( Hdpe ) Fittings Of 20 Mm To 225 Mm Od And Pressure 6.0 Kg / Cm2 And 10 Kg / Cm2 Suitable For Water Supply Which Is Available In All Standard Conforming To Isi -- 4984 / 14151 / 12786 / 13488, Iso 4427 , Din-8074Materials Rates Are Ex-Factory Excluding Transportation, Taxes And Duties. , Lowering, Laying And Jointing H. D. P. E. / M. D.P. E. Pipes In Proper Position Including All Specials By Compression Fitting / Electro Fusion And Butt Fusion Jointing Procedure As Per Relevant Is Code Complete With All Materials For Jointing Procedure Like Electro Fusion Machine, Electric Heater / Butt Fusion Welding Machine With Hydraulic Jack, Top Loading Clamp Etc. And All Labours As Directed By Engineer In Charge As Per Is-7634 Part Ii. , For Rising , 65 Mm Hdpe Pipe , 50 Mm Hdpe Pipe , For Distribution , 65 Mm Hdpe Pipe , 50 Mm Hdpe Pipe , 32 Mm Hdpe Pipe , 20 Mm Hdpe Pipe , 15 Mm Dia Gi Pipe , Supplying All Materials , Labour And Tools For Fixing 15 Mm Dia G.I. Pipes With Red Lead And Yarn Of Following Nominal Bore With Screwed And Socketed Joints On Wall, Ceiling And Floor Including Supplying And Fitting Of Wall Hooks Or Pipe Clamps, Wooden Plugs, Cutting Pipes To Size And Threading Ends If Required Etc. All Complete As Per Specification And Direction Of Engineer-In-Charge. , Supplying And Fixing G.I. Fittings Of Approved Make All Complete As Per Specification And Direction Of E / I. , Elbow 15 Mm Dia. , Reducer Socket 20X15 Mm Dia. , Nipple 15 Mm Dia. , Plain Socket 15 Mm Dia. , Supplying And Fixing G.M. Ferrule Of Approved Make In Existing C.I. / D.I. Main Including Drilling And Taping C.I. / D.I. Main All Complete As Per Specification And Direction Of E / I. 3 Mm, 6 Mm 10 Mm Dm Ferrule Weight Not Less Than 425 Gram. , Providing And Fixing Gun Metal Full Way Valve Of Approved Quality, All Complete, As Per Specification And Direction Of E / I. , 65 Mm Dia Full Way Valve , 50 Mm Dia And Weight Not Less Than 1.5 Kg. , Providing And Fixing Of Male Ended C.I.Body Brass Spindle Valve And Seat Bib Cock Of Approved Quality With Extra Socketall Complete As Per Specification And Direction Of E / I. , 15 Dia And Weight Not Less Than 400 Gm , Constructing Masonry Chamber 30X30x50 Cm Inside, In Brick Work In Cement Mortar 1:4 ( 1 Cement :4 Coarse Sand ) For Stop Cock, With C. I. Surface Box 100X100 X75 Mm ( Inside ) With Hinged Cover Fixed In Cement Concrete Slab 1:2:4 Mix ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size ) , I / C Necessary Excavation, Foundation Concrete 1:5:10 ( 1 Cement : 5 Fine Sand : 10 Graded Stone Aggregate 40Mm Nominal Size ) And Inside Plastering With Cement Mortar 1:3 ( 1 Cement : 3 Coarse Sand ) 12Mm Thick, Finished With A Floating Coat Of Neat Cement Complete As Per Standard Design.With Common Burnt Clay F.P.S. ( Non Modular ) Bricks Of Class Designation 7.5. , Full Way Valve Chamber , Supplying Materials , Labours And Equipments For Construction Of 0.90M X 0.90 M Size P.C.C. ( 1:2:4 ) Rectangular Platform With Stand Post In House Including 12 Mm Thick Cement Plaster In C.M. ( 1:4 ) With Neat Cement Punning Over Exposed Surfaceall Complete Job, As Per Approved Design, Specification And Direction Of E / I. , Providing Brick Masonry Chamber Ofinner Size 600 X 600 X 450 Mm Deep For Bore Well Protection Having 125 Mm Thick Wall And 75 Mm R.C.C Cover Including Cement Plaster Of Exposed Surface, Etc All Complete Job. , Earth Work In Back Filling The Trenches After Laying Different Types And Size Of Pipes With Earth Removed During Excavation Within Initial Lead And Lift As Per Specification And Direction Of Engineer-In-Charge. , Providing Fitting & Fixing 32 Mm To 50 Mm Service Hdpe Saddleall Complete Job, As Per Approved Design, Specification And Direction Of E / I. , Carriage Of Materials From Different Sources Or Departmental Stores To Work Site Including Loading, Transporting, Unloading And Stacking The Materials At Work Site Etc. All Complete Job. As Per Direction Of E / I. , Cement Lead 10 Km ( Avg. ) , Sand Lead 36 Km ( Avg. ) , Stone Chips Lead 11 Km ( Avg. ) , Steel Reinforcement Lead 10 Km ( Avg. ) , Bricks Lead 06 Km ( Avg. ) , Annual Operation & Maintenance Cost Based On Existing D / T Well With Solarmotor Pump For 5 Years , O & M Cost For 1St Year , O & M Cost For 2Nd Year , O & M Cost For 3Rd Year , O & M Cost For 4Th Year , O & M Cost For 5Th Year , Provision Of One No Sim Card & Its Recharging Cost For Rmc , Model-1B With Source ( Drilled T / W 125 / 115Dia Mm, 60M Deep ) , Tube Well , Drilling Portion , Construction For 115 / 125 Mm Dia Drilled Tube-Well For Drilling In All Kinds Of Soil Rock For Installation Of Hand Pump With D.T.H Rig Machine All Complete Including Supplying All Materials, Labours, Tools, Drilling, Rigs, Air Compressor And Equipments As Well As Fuel Lubricant For Making 125 / 115 Mm Dia Boring Etcand Cost Of Transporting Rig Machine And Other Vehicle Up To Site Workas Per Specification And Direction Of Engineer-In-Charge. , ( A ) Up To 30Mtr. Depth Bellow G.L. In Rural Areas , ( B ) Beyond 30Mtr.In Rural Areas , Providing All Equipments And Labour For Lowering 125Mm Dia Blue Upvc Casing Pipe As Casing For Protecting The Side From Falling During The Process Of Drilling All Complete Job Including Carriage Of Material To Work Site. , Supplying Labour Cement And Calcium Chloride Or Bentonite Solution And Equipments For Grouting To Casing Pipe All Complete Job Including Carriage Of Material To Work Site As Per Specification & Direction Of E / I , Supplying All Tools, Equipments And Labour And Doing Washing, Flushing And Development Of Drilled Tube Well To Give Clean And Clear Water All Complete As Per Direction E / I. , Supplying All Materials Labours And Equipment Including 125 Mm Dia Gi / Ci Cap 125 Mm Dia T / W Properly All Complete And Taking It Out As Per Specification & Direction Of E / I. ( The Cap Will Be Property Of Department ) , Civil Portion , Supplying All Tools, Equipment, Labours And Lowering 32 Mm Dia G.I. ( Medium ) Pipe In Dt In 3 Mtr. Length All Complete Job As Per Direction Of E / I. Including Carriage Of Materials. , Supplying All Tools, Labour For Fitting And Fixing Deep Well Cylinder With Necessary Connecting Rod All Complete Job As Per Specification & Direction Of E / I. , Supplying All Materials, Labours For Fitting And Fixing Of India Mark Ii Hand Pump With All Accessories All Job Complete As Per Direction Of E / I. Including Carriage Of Materials. , Supplying All Materials, Labours And Equipment For Constructing Pcc ( 1:2:4 ) Circular Platform Around Each Drilled Tube Well Including 12Mm Thick Cement Plaster ( 1:4 ) With Neat Cement Punning Over Exposed Surface As Per Unicef Design Etc. All Complete. Including Carriage Of Materials. , Supplying All Materials Labour And Equipment For Constructing Pcc ( 1:2:4 ) Drain As Per Unicef Design Etc. All Complete .Including Carriage Of Materials. , Add Extra Item For Supplying Tools, Labours And Materials For Painting, Numbering And Year For Construction Of T / Well And Taking Of Colour Photograph With Two Or Three Nearest Persons Including Platform, Drain, Soak Pit And Also Longitude & Latitude, Details Of T / W Such As Total Depth, Casing Depth, Static Water Level, Drawdown, Discharge, Strata Chart, Beneficiary Population Etc In Separate Sheet / Format All Complete As Per Direction Of E / I. , Cost Of Materials , Cost Of Standard I.S.I. Mark Deep Well Hand Pump For India Mark-Ii, I.S.I. 15500 ( Part 2 ) / 2004 With Latest Revision Including 12Mm X 3 Meter Long 8 No. Connecting Rods Made Of Bright Bar Electro-Galvanized Fitted With Coupler & Normal Stand Assembly Recommended For Use With Cylinder Assembly Suitable For Bore Wellcasing Pipe. , Cost Of 32 Mm Dia Gi Pipe ( Medium ) 3 Mtrs Long Screwed At Both Ends With Seamless Socket As Per Is:1239 ( Part 1990 ) . , Cost Of 125 Mm Dia Blue Upvc Casing Pipe As Per I.S.12818 / 2016 Cml No.- 5543459 , Rcc Foundation For Steel Structurestaging& Solar Panel , Earth Work In Excavation In Foundation Trenches In Ordinary Soil And Disposal Of Excavated Earth As Obtained To A Distance Up To 50.0M , Including All Lifts, Levelling , Ramming The Foundation Trenches, Removing Roots Of Trees, Shrubs All Complete As Per Approved Design , Building Specification And Direction Of E / I ( Vide Classification Of Soil Item -B ) , Providing Coarse Clean Sand In Filling In Foundation Trenches Or In Plinth Including Ramming And Watering In Layers Not Exceeding 150Mm Thick With All Leads And Lifts Including Cost Of All Materials , Labour , Royalty And Taxes All Complete As Per Building Specification And Direction Of E / I , Providing Designation 75 A One Brick Flat Soling Joints Filled With Local Sand Including Cost Of Watering Taxes Royalty All Complete As Per Building Specification And Direction Of E / I , Providing Nominal Mix Pcc Of ( 1:4:8 ) In Foundationwith Approved Quality Of Stone Chips 20Mm To 6Mm Size Graded And Clean Coarse Sand Of F.M.2.5To 3 Including Screening Shuttering Mixing Cement Concrete In Mixer And Placing In Position Vibrating Striking Curing And Royalty All Complete As Per Building Specification And Direction Of E / I , Providing Rcc M-20 In Nominal Mix Of ( 1:1.5:3 ) In Columnswith Approved Quality Of Stone Chips 20Mm To 6Mm Size Graded And Clean Coarse Sand Of F.M.2.5To 3 Including Screening Shuttering Mixing Cement Concrete In Mixer And Placing In Position Vibrating Striking Curing And Royalty All Complete As Per Building Specification And Direction Of E / I. , ( A ) Foundation For Steel Structure Staging , Footing And Vertical Pedestal Raft , Column , Tie Beam , ( B ) Foundation For Solar Panel , Footing , Vertical Pedestal , Providing For Steel Reinforcement As Per Approved Design And Drawing Excluding Carriage Of T.S. Bar To Work Site Cutting, Bending With Annealed Wire With Cost Of Wire, Removal Of Rust Placing The Rods In Position All Complete As Per Building Specification And Direction Of E / I. , ( A ) Foundation For Steel Structure Staging , Carriage Of Materials From Different Sources Or Departmental Stores To Work Site Including Loading, Transporting, Unloading And Stacking The Materials At Work Site Etc. All Complete Job. As Per Direction Of E / I. , Cement Lead 10 Km ( Avg. ) , Sand Lead 36 Km ( Avg. ) , Stone Chips Lead 11 Km ( Avg. ) , Steel Reinforcement Lead 10 Km ( Avg. ) , Bricks Lead 06 Km ( Avg. ) , Galvanized Tubular Steel Structure Staging Forhdpe Water Storage Tank& Solar Panel , Providing Structural Steel Galvanisedsqure Pipe Section Work In Trusses, Other Similar Trussed Purlins And Members With All Bracing , Gusset Plates Etc As Per Detailed Design And Drawing Or As Directed By Engineer- In-Charge , Including Cutting Fabricating , Hoisting , Erecting And Fixing In Position , Making Riveted / Bolted / Welded Connections And One Coat Of Anticorrosive Paint And Over It Two Coat Of All Oil Painting & For Structure ( Plus ) Providing And Applying Materials &Labour For Hot Dip Galvanizing Of Above Structure Including Transportation For Galvanizing Minimum Thickness 80Microns ( Net Wt. Of Components To Be Galv ) Preferably Tata Structural Section Etc Complete. , Hardware ( L.S. ) , Information Board For Iec , Providing Structural Steel Work In Trusses Other Similar Trussed Purlins And Members With Bracing Gusset Plates Etc As Per Detailed Design And Drawing Or As Directed By Engineer- In-Charge Including Cutting Fabricating Hoisting Erecting And Fixing In Position Making Reverted Bolted Welded Connections One Coat Of Anticorrosive Paint And Over It Two Coats Of Oil Painting Etc Complete , Installation Of 5000 Liters Capacity Water Storage Tank , Providing And Fixing Hdpe Container Syntex Or Alike One Piecemolded Water Tank Made Out Of Low Density Polythyler Andbuilt Corrugation Including Of Delivery Up To Destination Hoisting And Fixing Of Accessories Such As Inlet, Outlet Overflow Of All Tanks Capacity 5000.00 Litres Capacity Water Storage Tank , Transportation Charge , Lifting Of 5000 Litrs Capacity Tank Up To 4.00M Height With Lifting Tools With Rope And Labour , Making Hole In Tank , Making Long Screw In G.I. Pipe Including Supplying And Fitting Jam Nuts And Extra Socket Etc. , Rising And Distribution Network With House Connection Up To 20 Nos. Including Platform & Stand Post , Earth Work In Excavation In Foundation Trenches In Hard Soil ( Vide Classification Soil Item B ) And Disposal Of Excavated Earth As Obtained To A Distance Up To 50 Mtr. Including All Lifts, Leveling, Ramming The Foundation Trenches, Removing Roots Of Trees, Shrubs All Complete As Per Approved Design, Specification And Direction Of E / I. , Dismantling Plain Cement Concrete Work Including Stacking Serviceable Materials In Countable Stacks Within 15 M Lead And Disposal Of Unserviceable Materials With All Leads All Complete , Providing Pccm-200 With Nominal Mix Of ( 1:1.5:3 ) With Approved Quality Of Stone Chips 20 Mm To 6 Mm Size Graded And Clean Coarse Sand Of Fm 2.5 To 3.0 Including Screening, Shuttering, Mixing Cement Concrete In Mixer And Placing In Position, Vibrating, Sticking, Curing , Taxes And Royalty All Complete As Per Specification And Direction Of E / I. For Construction Of Road Cutting Portion , Rising Main , Manufacture, Supply And Delivery Offollowing Nominal Dia Upvc Column Pipes Including Pvc Socket ( Coupler ) , , 65Mm Dia -Density Of Pipe 1.38 To 1.43 Gm Per Cm3 Od:74.5 To 75.2Mm Wall Thickness End:9Mm To 10.7Mm, Barrel 9Mm To 10.7 Mm, Length: 3Mtrs.Rising Main , 50 Mm Dia -Density Of Pipe 1.38 To 1.43 Gm Per Cm3 Od:87.5 To 88.2Mm Wall Thickness End:9 .8 Mm To 11.9Mm, Barrel 7.3Mm To 9 Mm, Length: 3Mtrs. Delivery Pipe , Distribution , Providing And Supplying High Density Polyethylene Pipe ( Hdpe Pipe ) Of 20 Mm To 225 Mm Od And Pressure 6.0 Kg / Cm2 And 10 Kg / Cm2 Suitable For Water Supply Which Is Available In All Standard Conforming To Isi -- 4984 / 14151 / 12786 / 13488, Iso 4427 , Din-8074Materials Rates Are Ex-Factory Excluding Transportation, Taxes And Duties. , 63 Mm Hdpe Pipe , 50 Mm Hdpe Pipe , 32 Mm Hdpe Pipe , 20 Mm Hdpe Pipe , Providing And Fixing Gun Metal Gate Valvewith C I Wheel Of Approved Quality ( Screwed End ) . , 65 Mm Dia , 50Mm Dia , Providing And Supplying High Density Polyethylene ( Hdpe ) Fittings Of 20 Mm To 225 Mm Od And Pressure 6.0 Kg / Cm2 And 10 Kg / Cm2 Suitable For Water Supply Which Is Available In All Standard Conforming To Isi -- 4984 / 14151 / 12786 / 13488, Iso 4427 , Din-8074Materials Rates Are Ex-Factory Excluding Transportation, Taxes And Duties. , Lowering, Laying And Jointing H. D. P. E. / M. D.P. E. Pipes In Proper Position Including All Specials By Compression Fitting / Electro Fusion And Butt Fusion Jointing Procedure As Per Relevant Is Code Complete With All Materials For Jointing Procedure Like Electro Fusion Machine, Electric Heater / Butt Fusion Welding Machine With Hydraulic Jack, Top Loading Clamp Etc. And All Labours As Directed By Engineer In Charge As Per Is-7634 Part Ii. , For Rising , 50 Mm Hdpe Pipe , 65 Mm Hdpe Pipe , Distribution , 65 Mm Hdpe Pipe , 50 Mm Hdpe Pipe , 32 Mm Hdpe Pipe , 20 Mm Hdpe Pipe , Providing 15 Mm Dia. G.I. Pipe Tata Or Equivalent Make As Per Is 1239 ( Part 1 / 2004 ) Isi Mark / Medium Quality In Stand Post. , Supplying All Materials , Labour And Tools For Fixing 15 Mm Dia G.I. Pipes With Red Lead And Yarn Of Following Nominal Bore With Screwed And Socketed Joints On Wall, Ceiling And Floor Including Supplying And Fitting Of Wall Hooks Or Pipe Clamps, Wooden Plugs, Cutting Pipes To Size And Threading Ends If Required Etc. All Complete As Per Specification And Direction Of Engineer-In-Charge. , Supplying And Fixing G.I. Fittings Of Approved Make All Complete As Per Specification And Direction Of E / I. , Elbow 15 Mm Dia. , Reducer Socket 20X15 Mm Dia. , Nipple 15 Mm Dia. , Plain Socket 15 Mm Dia. , Supplying And Fixing G.M. Ferrule Of Approved Make In Existing C.I. / D.I. Main Including Drilling And Taping C.I. / D.I. Main All Complete As Per Specification And Direction Of E / I. 3 Mm, 6 Mm 10 Mm Dm Ferrule Weight Not Less Than 425 Gram. , Providing And Fixing Gun Metal Full Way Valve Of Approved Quality, All Complete, As Per Specification And Direction Of E / I. , 65 Mm Dia Full Way Valve , 50 Mm Dia And Weight Not Less Than 1.5 Kg. , Providing And Fixing Of Male Ended C.I.Body Brass Spindle Valve And Seat Bib Cock Of Approved Quality With Extra Socketall Complete As Per Specification And Direction Of E / I. , 15 Dia And Weight Not Less Than 400 Gm , Constructing Masonry Chamber 30X30x50 Cm Inside, In Brick Work In Cement Mortar 1:4 ( 1 Cement :4 Coarse Sand ) For Stop Cock, With C. I. Surface Box 100X100 X75 Mm ( Inside ) With Hinged Cover Fixed In Cement Concrete Slab 1:2:4 Mix ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size ) , I / C Necessary Excavation, Foundation Concrete 1:5:10 ( 1 Cement : 5 Fine Sand : 10 Graded Stone Aggregate 40Mm Nominal Size ) And Inside Plastering With Cement Mortar 1:3 ( 1 Cement : 3 Coarse Sand ) 12Mm Thick, Finished With A Floating Coat Of Neat Cement Complete As Per Standard Design.With Common Burnt Clay F.P.S. ( Non Modular ) Bricks Of Class Designation 7.5. Full Way Valve Chamber , Supplying Materials , Labours And Equipments For Construction Of 0.90M X 0.90 M Size P.C.C. ( 1:2:4 ) Rectangular Platform With Stand Post In House Including 12 Mm Thick Cement Plaster In C.M. ( 1:4 ) With Neat Cement Punning Over Exposed Surfaceall Complete Job, As Per Approved Design, Specification And Direction Of E / I. , Providing Brick Masonry Chamber Ofinner Size 600 X 600 X 450 Mm Deep For Bore Well Protection Having 125 Mm Thick Wall And 75 Mm R.C.C Cover Including Cement Plaster Of Exposed Surface, Etc All Complete Job , Earth Work In Back Filling The Trenches After Laying Different Types And Size Of Pipes With Earth Removed During Excavation Within Initial Lead And Lift As Per Specification And Direction Of Engineer-In-Charge. , Providing Fitting & Fixing 32 Mm To 50 Mm Service Hdpe Saddleall Complete Job, As Per Approved Design, Specification And Direction Of E / I. , Carriage Of Materials From Different Sources Or Departmental Stores To Work Site Including Loading, Transporting, Unloading And Stacking The Materials At Work Site Etc. All Complete Job. As Per Direction Of E / I. , Cement Lead 10 Km ( Avg. ) , Sand Lead 36 Km ( Avg. ) , Stone Chips Lead 11 Km ( Avg. ) , Steel Reinforcement Lead 10 Km ( Avg. ) , Bricks Lead 06 Km ( Avg. ) , Solar Photovoltaic ( Spv ) Solar Submersible D.C. Water Motor Pump , Designing, Supplying, Installation, Testing & Commissioning With All Tools & Parts Of Following Solar Photovoltaic ( Spv ) Solar Submersible D.C. Water Motor Pump Suitable For Minimum 125Mm X 115Mm Bore Well As Per Mnre Guideline With Following Specifications & Accessories. , Spv Arrays Contains Specified No Of Same Capacity Type & Specification Modules Connected To Series Or Parallel To Obtained The Required Voltage & Current The Power Output Of Individual Pvmodules Should Be Minimum 200 Watt Peak. , I ) The Spv Modules Should Be As Per Iec-61215 And Iec 61730 Part 1.0 ) , Ii ) All External Parts Of Motor Pump Used In Submersible Pump Which Are In Contact Of Water Is Stainless Steel Grade 303 Or Higher As Required. , Iii ) The Pv Modules Shouldbe Mounted On Metallic Structure Of Adequate Strength And Appropriate Design Which Can Withstand Load Of Modules & High Wind Pressure Up To 200Km / H. , Iv ) The Module Mounting Structure Should Be Hot Dip Galvanized According To Is 4759. , V ) To Enhance The Performance Of Spv Water Pumping System & Arrangement For Seasonal Tilt Angle Adjustment Should Be Provided , Vi ) Necessary Arrangement Should Be Provided In Controller Automatic Start-Run-Stop Through Out The Day With Water Level Detection System. ( As Per Mnre Specification ) , Vii ) Necessary Protection Such As Lightening Arrestor Etc. Should Be Provided To Protect The Controller & Spv , Viii ) The Suction / Delivery Pipe Shall Be Upvc / H.D.P.E. Pipes Of Appropriate Size 60M Or More As Required Minimum Pressure Rating Of 8Kg / Sq Cm- Pe 100 Grade For Pump Up To 3Hp & 10 Kg / Sq Cm- Pe 100 Grade For 5 Hp. , Ix ) All Cable Used Shall Be As Per Is 694. Suitable Size Of Cable Shall Be Used In Sufficient Length For Inter Connection Between The Spv Array To Spv Controller And Spv Controller To Solar Power Pump. Provision Of Cable Shall Be As Per Is 14536. , X ) The Motor Pump Set Should Have A 5 Years Warranty. , Xi ) Control Panel Suitable For Motor Pump With Arrangement Of Dry Run & Over Flow Protection Sensor, Float Switch & Rain Prevention Box. ( As Per Mnre Specification ) , Xii ) The Spv Controller Must Have Ip-65 Protection Or Must Be Housed In Cabinet Having At Least Ip-65 Protection. , Xiii ) The System Should Be As Per Mnre Guide Line & Eco-Friendly With Suitable Arrangement To Operate New Pump Manually. , Xiv ) With Third Party Inspection Before Dispatch. , Xv ) Provision For Web Basedremote Monitoring Of The Pumps To Be Installed Must Be Made Through The Inbuilt Controllers . It Should Be Possible To Ascertain The Daily Water Output, The Power Generated By Pv Array , The Up And Downtime Of The Pump During The Year, Number Of Days The Pump Was Unused Or Under Breakdown Repairs. , The Following Details Should Be Marked Indelibly On The Motor Pump Set , A ) Name Of The Manufacturer Or Distinctive Logo. , B ) Model Number. , C ) Serial Number. , Solar Submersible Motor Pump ( Spv Dc Type ) , I ) 1 Hp ( Dc Pump ) With 900 Wp Minimum Watt P.V. Panel As Mnre Pump Head Max Shut-Off Head Up To 120 Mtrs. For Higher Or Lower Head Or In Between Various Modules Output Could Be Decided On Prorates Basis. ( As Per Latest Guide Line Of Mnre ) , Carrying Out Recuperation / Yield Test For Ascertaining The Discharge Of Constructed Well / Excavated Profile As Directed By The Iec. The Testout By The Drawing Down Water From The Well / Profile Below Normal / Subsoil Water Level Up To Full Depth Rise Is Recorded The Normal Water Level / Subsoil Water Level In The Well / Profile As Well As Strainer / Level At Pump As Per Design Of W.S. Scheme Shall Be Recorded Prior To The Test Including Cost Of All Materials, Over Load , Labours Etc. Complete As Directed. , Supplying All Labours, Tools And Equipments For Dismantling Of Head & Water Tank Assembly And Taking Out 32 Mm Dia Old G.I. Pipe, Connecting Rod, Cylinder Assembly The Dismantled Components After Necessary Changing For Making The T / W In Good Condition With All Transportation Including Unused Taken Out Materials Back In Store All Complete Job As Per Direction Of E / I. ( As Per Model Estimate Of Solar Energy Based Mini Wss. Ts Done By Se, Ranchi Circle & Circle Gumla Dt. 21.05.2019 ) , Provision Of Solar Night Lamp. , Galvanised Chain-Line Mess Fencing Around Solar Panel Where Bore Well Is Away From Tower , Making 30 Cm ( 12 ) Dia Bore Up To 4M Below Ground With Hand Auger Of Approved Quality In Ordinary Soil ( Vide Classification Of Soil Item-A ) True To Plum And Without Eccentricity In Any Stage Of Operation And Disposal Of The Exacavated Earth Up To 50M Lead Including All Lifts All Complete As Per Approved Design And Direction Of E / I. , Providing Pcc M-150 In Nominal Mix Of ( 1:2:4 ) In Foundationwith Approved Quality Of Stone Chips 20Mm To 6Mm Size Graded And Clean Coarse Sand Of F.M.2.5 To 3 Including Screening Shuttering, Mixing Cement Concrete In Mixer And Placing In Position, Vibrating, Curing, Taxes And Royalty All Complete As Per Building Specification Direction Of E / I. , Labour Cost Of Fitting And Fixing Galvanised Chain-Link Mess Up Height Of 2 M Including Cost Of Staples ( But Excluding The Cost Of Cement Concete Angle Iron Posts, Its Cutting And Making Holes, Nuts And Bolts ) All Complete As Per Specification And Direction Of E / I. , Drilling 6Mm Dia Holes In M.S Angle Iron For Fixing Of Stables Etc. As Per Building Specification And Direction Of E / I. , Labour Cost Cutting Of M.S Angle Iron Posts To Required Length, One End Splitted As Fish Tailed In A Length Of 150Mm Complete As Per Building Sepcification And Direction Of E / I. , Supplying, Fitting And Fixing Straining Bolts With Nut Size 22Cm*10Mm Dia Tighten The Barbed Wire With Corner Post Complete As Per Building Specification And Direction Of E / I. , Supplying, Fitting And Fixing Galvanised Chain -Link Mess Having 3Mm Thick Wire Cell Type 40 X 40 Mm Fitted On M.S. Angle Frame With Two Diagonals Having 25X25x5mm Size Angle Including Cost Of Fabrication, Providing Necessary Bocking Arrangement With Haskal And Domny Duly Fixed In Angle Post, Applying A Priming Red Lead Paint Over Steel Work, Taxes Excluding The Cost Of Galvanised Chain-Link Mess All Complete. , Cost Of Galvanised Chain-Link Mess Having 3 Mm Thick Wire Cell Type 40X40 Mm Not Less Than 3.1 Kg / Sqm , Cost Of 50 X 50 X 6 Mm M.S Angle , Carriage Of Materials From Different Sources Or Departmental Stores To Work Site Including Loading, Transporting, Unloading And Stacking The Materials At Work Site Etc. All Complete Job. As Per Direction Of E / I. , Cement Lead 10 Km ( Avg. ) , Sand Lead 36 Km ( Avg. ) , Stone Chips Lead 11 Km ( Avg. ) , Steel Reinforcement Lead 10 Km ( Avg. ) , Annual Operation & Maintenance Cost Based On Existing D / T Well With Solarmotor Pump For 5 Years , O & M Cost For 1St Year ( Excluding Repair Charges ) , O & M Cost For 2Nd Year With Annual Repair Charges , O & M Cost For 3Rd Year , O & M Cost For 4Th Year , O & M Cost For 5Th Year , Provision Of One No Sim Card & Its Recharging Cost For Rmc , 18% Gst , Labour Cess
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 7
32.
Drinking Water Supply and Sanitation #9062066 Technical Bid
Construction Of Solar Based Mrwss Svs In Pirtand Block, Comprising Of Suitable R.C.C Framed Structure Esr Distribution Lines, Source ( As Required ) And Fhtc All Complete Under Drinking Water Sanitation Division No 2 Giridih Cluster No 22 , Model-1Awith Source ( Drilled T / W 125 / 115 Dia Mm, 60M Deep ) , Tube Well , Drilling Portion , Construction For 115 / 125 Mm Dia Drilled Tube-Well For Drilling In All Kinds Of Soil Rock For Installation Of Hand Pump With D.T.H Rig Machine All Complete Including Supplying All Materials, Labours, Tools, Drilling, Rigs, Air Compressor And Equipments As Well As Fuel Lubricant For Making 125 / 115 Mm Dia Boring Etcand Cost Of Transporting Rig Machine And Other Vehicle Up To Site Workas Per Specification And Direction Of Engineer-In-Charge. , ( A ) Up To 30Mtr. Depth Bellow G.L. In Rural Areas , ( B ) Beyond 30Mtr.In Rural Areas , Providing All Equipments And Labour For Lowering 125Mm Dia Blue Upvc Casing Pipe As Casing For Protecting The Side From Falling During The Process Of Drilling All Complete Job Including Carriage Of Material To Work Site. , Supplying Labour Cement And Calcium Chloride Or Bentonite Solution And Equipments For Grouting To Casing Pipe All Complete Job Including Carriage Of Material To Work Site As Per Specification & Direction Of E / I , Supplying All Tools, Equipments And Labour And Doing Washing, Flushing And Development Of Drilled Tube Well To Give Clean And Clear Water All Complete As Per Direction E / I. , Supplying All Materials Labours And Equipment Including 125 Mm Dia Gi / Ci Cap 125 Mm Dia T / W Properly All Complete And Taking It Out As Per Specification & Direction Of E / I. ( The Cap Will Be Property Of Department ) , Civil Portion , Supplying All Tools, Equipment, Labours And Lowering 32 Mm Dia G.I. ( Medium ) Pipe In Dt In 3 Mtr. Length All Complete Job As Per Direction Of E / I. Including Carriage Of Materials. , Supplying All Tools, Labour For Fitting And Fixing Deep Well Cylinder With Necessary Connecting Rod All Complete Job As Per Specification & Direction Of E / I. , Supplying All Materials, Labours For Fitting And Fixing Of India Mark Ii Hand Pump With All Accessories All Job Complete As Per Direction Of E / I. Including Carriage Of Materials. , Supplying All Materials, Labours And Equipment For Constructing Pcc ( 1:2:4 ) Circular Platform Around Each Drilled Tube Well Including 12Mm Thick Cement Plaster ( 1:4 ) With Neat Cement Punning Over Exposed Surface As Per Unicef Design Etc. All Complete. Including Carriage Of Materials. , Supplying All Materials Labour And Equipment For Constructing Pcc ( 1:2:4 ) Drain As Per Unicef Design Etc. All Complete .Including Carriage Of Materials. , Add Extra Item For Supplying Tools, Labours And Materials For Painting, Numbering And Year For Construction Of T / Well And Taking Of Colour Photograph With Two Or Three Nearest Persons Including Platform, Drain, Soak Pit And Also Longitude & Latitude, Details Of T / W Such As Total Depth, Casing Depth, Static Water Level, Drawdown, Discharge, Strata Chart, Beneficiary Population Etc In Separate Sheet / Format All Complete As Per Direction Of E / I. , Cost Of Materials , Cost Of Standard I.S.I. Mark Deep Well Hand Pump For India Mark-Ii, I.S.I. 15500 ( Part 2 ) / 2004 With Latest Revision Including 12Mm X 3 Meter Long 8 No. Connecting Rods Made Of Bright Bar Electro-Galvanized Fitted With Coupler & Normal Stand Assembly Recommended For Use With Cylinder Assembly Suitable For Bore Wellcasing Pipe. , Cost Of 32 Mm Dia Gi Pipe ( Medium ) 3 Mtrs Long Screwed At Both Ends With Seamless Socket As Per Is:1239 ( Part 1990 ) . , Cost Of 125 Mm Dia Blue Upvc Casing Pipe As Per I.S.12818 / 2016 Cml No.- 5543459 , Solar Photovoltaic ( Spv ) Solar Submersible D.C. Water Motor Pump , Designing, Supplying, Installation, Testing & Commissioning With All Tools & Parts Of Following Solar Photovoltaic ( Spv ) Solar Submersible D.C. Water Motor Pump Suitable For Minimum 125Mm X 115Mm Bore Well As Per Mnre Guideline With Following Specifications & Accessories. , Spv Arrays Contains Specified No Of Same Capacity Type & Specification Modules Connected To Series Or Parallel To Obtained The Required Voltage & Current The Power Output Of Individual Pvmodules Should Be Minimum 200 Watt Peak. , I ) The Spv Modules Should Be As Per Iec-61215 And Iec 61730 Part 1.0 ) , Ii ) All External Parts Of Motor Pump Used In Submersible Pump Which Are In Contact Of Water Is Stainless Steel Grade 303 Or Higher As Required. , Iii ) The Pv Modules Shouldbe Mounted On Metallic Structure Of Adequate Strength And Appropriate Design Which Can Withstand Load Of Modules & High Wind Pressure Up To 200Km / H. , Iv ) The Module Mounting Structure Should Be Hot Dip Galvanized According To Is 4759. , V ) To Enhance The Performance Of Spv Water Pumping System & Arrangement For Seasonal Tilt Angle Adjustment Should Be Provided , Vi ) Necessary Arrangement Should Be Provided In Controller Automatic Start-Run-Stop Through Out The Day With Water Level Detection System. ( As Per Mnre Specification ) , Vii ) Necessary Protection Such As Lightening Arrestor Etc. Should Be Provided To Protect The Controller & Spv , Viii ) The Suction / Delivery Pipe Shall Be Upvc / H.D.P.E. Pipes Of Appropriate Size 60M Or More As Required Minimum Pressure Rating Of 8Kg / Sq Cm- Pe 100 Grade For Pump Up To 3Hp & 10 Kg / Sq Cm- Pe 100 Grade For 5 Hp. , Ix ) All Cable Used Shall Be As Per Is 694. Suitable Size Of Cable Shall Be Used In Sufficient Length For Inter Connection Between The Spv Array To Spv Controller And Spv Controller To Solar Power Pump. Provision Of Cable Shall Be As Per Is 14536. , X ) The Motor Pump Set Should Have A 5 Years Warranty. , Xi ) Control Panel Suitable For Motor Pump With Arrangement Of Dry Run & Over Flow Protection Sensor, Float Switch & Rain Prevention Box. ( As Per Mnre Specification ) , Xii ) The Spv Controller Must Have Ip-65 Protection Or Must Be Housed In Cabinet Having At Least Ip-65 Protection. , Xiii ) The System Should Be As Per Mnre Guide Line & Eco-Friendly With Suitable Arrangement To Operate New Pump Manually. , Xiv ) With Third Party Inspection Before Dispatch. , Xv ) Fitting, Fixing & Mounting On Water Tank Steel Structure. , Xvi ) Provision For Web Basedremote Monitoring Of The Pumps To Be Installed Must Be Made Through The Inbuilt Controllers . It Should Be Possible To Ascertain The Daily Water Output, The Power Generated By Pv Array , The Up And Downtime Of The Pump During The Year, Number Of Days The Pump Was Unused Or Under Breakdown Repairs. , The Following Details Should Be Marked Indelibly On The Motor Pump Set , A ) Name Of The Manufacturer Or Distinctive Logo. , B ) Model Number. , C ) Serial Number. , Solar Submersible Motor Pump ( Spv Dc Type ) , I ) 1 Hp ( Dc Pump ) With 900 Wp Minimum Watt P.V. Panel As Mnre Pump Head Max Shut-Off Head Up To 120 Mtrs. For Higher Or Lower Head Or In Between Various Modules Output Could Be Decided On Prorates Basis. ( As Per Latest Guide Line Of Mnre ) , Carrying Out Recuperation / Yield Test For Ascertaining The Discharge Of Constructed Well / Excavated Profile As Directed By The Iec. The Testout By The Drawing Down Water From The Well / Profile Below Normal / Subsoil Water Level Up To Full Depth Rise Is Recorded The Normal Water Level / Subsoil Water Level In The Well / Profile As Well As Strainer / Level At Pump As Per Design Of W.S. Scheme Shall Be Recorded Prior To The Test Including Cost Of All Materials, Over Load , Labours Etc. Complete As Directed. , Supplying All Labours, Tools And Equipments For Dismantling Of Head & Water Tank Assembly And Taking Out 32 Mm Dia Old G.I. Pipe, Connecting Rod, Cylinder Assembly The Dismantled Components After Necessary Changing For Making The T / W In Good Condition With All Transportation Including Unused Taken Out Materials Back In Store All Complete Job As Per Direction Of E / I. , Provision Of Solar Night Lamp. , Construction Rcc Foundation For Steel Structurestaging& Solar Panel , Earth Work In Excavation In Foundation Trenches In Ordinary Soil And Disposal Of Excavated Earth As Obtained To A Distance Up To 50.0M , Including All Lifts, Levelling , Ramming The Foundation Trenches, Removing Roots Of Trees, Shrubs All Complete As Per Approved Design , Building Specification And Direction Of E / I ( Vide Classification Of Soil Item -B ) , Providing Coarse Clean Sand In Filling In Foundation Trenches Or In Plinth Including Ramming And Watering In Layers Not Exceeding 150Mm Thick With All Leads And Lifts Including Cost Of All Materials , Labour , Royalty And Taxes All Complete As Per Building Specification And Direction Of E / I ( Mode Of Measurement Compacted Volume ) , Providing Designation 75 A One Brick Flat Soling Joints Filled With Local Sand Including Cost Of Watering Taxes Royalty All Complete As Per Building Specification And Direction Of E / I , Providing Pcc M-150 In Nominal Mix Of ( 1:2:4 ) In Foundationwith Approved Quality Of Stone Chips 20Mm To 6Mm Size Graded And Clean Coarse Sand Of F.M.2.5To 3 Including Screening Shuttering Mixing Cement Concrete In Mixer And Placing In Position Vibrating Striking Curing And Royalty All Complete As Per Building Specification And Direction Of E / I , Providing Rcc M-200 In Nominal Mix Of ( 1:1.5:3 ) In Columnswith Approved Quality Of Stone Chips 20Mm To 6Mm Size Graded And Clean Coarse Sand Of F.M.2.5To 3 Including Screening Shuttering Mixing Cement Concrete In Mixer And Placing In Position Vibrating Striking Curing And Royalty All Complete As Per Building Specification And Direction Of E / I. , ( A ) Foundation For Steel Structure Staging , Footing , Vertical Pedestal , Tie Beam , ( B ) Foundation For Solar Panel , Footing , Vertical Pedestal , Providing For Steel Reinforcement As Per Approved Design And Drawing Excluding Carriage Of T.S. Bar To Work Site Cutting, Bending With Annealed Wire With Cost Of Wire, Removal Of Rust Placing The Rods In Position All Complete As Per Building Specification And Direction Of E / I. , 10 Mm Dia , 12 Mm Dia , Carriage Of Construction Materials To Work Site Including Loading, Unloading & Stacking Etc. All Complete. , Cement10km Lead , Steel10km Lead , Stone Chips 11Km Lead , Sand36km Lead , Bricks 06Km Lead , Construction Ofgalvanized Tubular Steel Structure Staging For ( 4.5M ) Hdpe Water Storage Tank& Solar Panel. , Providing Structural Steel Galvanised Tubular Hollow Section Work In Trusses, Other Similar Trussed Purlins And Members With All Bracing , Gusset Plates Etc As Per Detailed Design And Drawing Or As Directed By Engineer- In-Charge , Including Cutting Fabricating , Hoisting , Erecting And Fixing In Position , Making Riveted / Bolted / Welded Connections And One Coat Of Anticorrosive Paint And Over It Two Coat Of All Oil Painting & For Structure ( Plus ) Providing And Applying Materials &Labour For Hot Dip Galvanizing Of Above Structure Including Transportation For Galvanizing Minimum Thickness 80Microns ( Net Wt. Of Components To Be Galv ) Preferably Tata Structural Section Etc Complete. , Providing Structural Steel Work In Trusses Other Similar Trussed Purlins And Members With Bracing Gusset Plates Etc As Per Detailed Design And Drawing Or As Directed By Engineer- In-Charge Including Cutting Fabricating Hoisting Erecting And Fixing In Position Making Reverted Bolted Welded Connections One Coat Of Anticorrosive Paint And Over It Two Coats Of Oil Painting Etc Complete. , Materials And Labour For Vinyl Painting Of Matter Given By Department In Different Color , Installation Of 2000 Liters Capacity Water Storage Tank , Providing And Fixing Hdpe Container Syntex Or Alike One Piecemolded Water Tank Made Out Of Low Density Polythyler Andbuilt Corrugation Including Of Delivery Up To Destination Hoisting And Fixing Of Accessories Such As Inlet, Outlet Overflow Of All Tanks Capacity 2000.00 Litres Capacity Water Storage Tank , Transportation Charge , Lifting Of 2000 Litrs Capacity Tank Up To 4.5M Height With Lifting Tools With Rope And Labour , Making Hole In Tank , Making Long Screw In G.I. Pipe Including Supplying And Fitting Jam Nuts And Extra Socket Etc. , Rising And Distribution Network With House Connection Up To 10 Nos. Including Platform & Stand Post , Earth Work In Excavation In Foundation Trenches In Hard Soil ( Vide Classification Soil Item B ) And Disposal Of Excavated Earth As Obtained To A Distance Up To 50 Mtr. Including All Lifts, Leveling, Ramming The Foundation Trenches, Removing Roots Of Trees, Shrubs All Complete As Per Approved Design, Specification And Direction Of E / I. , Dismantling Plain Cement Concrete Work Including Stacking Serviceable Materials In Countable Stacks Within 15 M Lead And Disposal Of Unserviceable Materials With All Leads All Complete. , Providing Pccm-200 With Nominal Mix Of ( 1:1.5:3 ) With Approved Quality Of Stone Chips 20 Mm To 6 Mm Size Graded And Clean Coarse Sand Of Fm 2.5 To 3.0 Including Screening, Shuttering, Mixing Cement Concrete In Mixer And Placing In Position, Vibrating, Sticking, Curing , Taxes And Royalty All Complete As Per Specification And Direction Of E / I. For Construction Of Road Cutting Portion. , Rising Main , Manufacture, Supply And Delivery Offollowing Nominal Dia Upvc Column Pipes Including Pvc Socket ( Coupler ) , , 65Mm Dia -Density Of Pipe 1.38 To 1.43 Gm Per Cm3 Od:74.5 To 75.2Mm Wall Thickness End:9Mm To 10.7Mm, Barrel 9Mm To 10.7 Mm, Length: 3Mtrs.Rising Main , 50 Mm Dia -Density Of Pipe 1.38 To 1.43 Gm Per Cm3 Od:87.5 To 88.2Mm Wall Thickness End:9 .8 Mm To 11.9Mm, Barrel 7.3Mm To 9 Mm, Length: 3Mtrs. Delivery Pipe , Distribution Main , Providing And Supplying High Density Polyethylene Pipe ( Hdpe Pipe ) Of 20 Mm To 225 Mm Od And Pressure 6.0 Kg / Cm2 And 10 Kg / Cm2 Suitable For Water Supply Which Is Available In All Standard Conforming To Isi -- 4984 / 14151 / 12786 / 13488, Iso 4427 , Din-8074Materials Rates Are Ex-Factory Excluding Transportation, Taxes And Duties. Pe-80 , Pn- 10. , 63 Mm Hdpe Pipe , 50 Mm Hdpe Pipe , 32 Mm Hdpe Pipe- , 20 Mm Hdpe Pipe- , Providing And Fixing Gun Metal Gate Valvewith C I Wheel Of Approved Quality ( Screwed End ) . , 65 Mm Dia , 50 Mm Dia . , Providing And Supplying High Density Polyethylene ( Hdpe ) Fittings Of 20 Mm To 225 Mm Od And Pressure 6.0 Kg / Cm2 And 10 Kg / Cm2 Suitable For Water Supply Which Is Available In All Standard Conforming To Isi -- 4984 / 14151 / 12786 / 13488, Iso 4427 , Din-8074Materials Rates Are Ex-Factory Excluding Transportation, Taxes And Duties. , Lowering, Laying And Jointing H. D. P. E. / M. D.P. E. Pipes In Proper Position Including All Specials By Compression Fitting / Electro Fusion And Butt Fusion Jointing Procedure As Per Relevant Is Code Complete With All Materials For Jointing Procedure Like Electro Fusion Machine, Electric Heater / Butt Fusion Welding Machine With Hydraulic Jack, Top Loading Clamp Etc. And All Labours As Directed By Engineer In Charge As Per Is-7634 Part Ii. , For Rising , 65 Mm Hdpe Pipe , 50 Mm Hdpe Pipe , For Distribution , 65 Mm Hdpe Pipe , 50 Mm Hdpe Pipe , 32 Mm Hdpe Pipe , 20 Mm Hdpe Pipe , 15 Mm Dia Gi Pipe , Supplying All Materials , Labour And Tools For Fixing 15 Mm Dia G.I. Pipes With Red Lead And Yarn Of Following Nominal Bore With Screwed And Socketed Joints On Wall, Ceiling And Floor Including Supplying And Fitting Of Wall Hooks Or Pipe Clamps, Wooden Plugs, Cutting Pipes To Size And Threading Ends If Required Etc. All Complete As Per Specification And Direction Of Engineer-In-Charge. , Supplying And Fixing G.I. Fittings Of Approved Make All Complete As Per Specification And Direction Of E / I. , Elbow 15 Mm Dia. , Reducer Socket 20X15 Mm Dia. , Nipple 15 Mm Dia. , Plain Socket 15 Mm Dia. , Supplying And Fixing G.M. Ferrule Of Approved Make In Existing C.I. / D.I. Main Including Drilling And Taping C.I. / D.I. Main All Complete As Per Specification And Direction Of E / I. 3 Mm, 6 Mm 10 Mm Dm Ferrule Weight Not Less Than 425 Gram. , Providing And Fixing Gun Metal Full Way Valve Of Approved Quality, All Complete, As Per Specification And Direction Of E / I. , 65 Mm Dia Full Way Valve , 50 Mm Dia And Weight Not Less Than 1.5 Kg. , Providing And Fixing Of Male Ended C.I.Body Brass Spindle Valve And Seat Bib Cock Of Approved Quality With Extra Socketall Complete As Per Specification And Direction Of E / I. , 15 Dia And Weight Not Less Than 400 Gm , Constructing Masonry Chamber 30X30x50 Cm Inside, In Brick Work In Cement Mortar 1:4 ( 1 Cement :4 Coarse Sand ) For Stop Cock, With C. I. Surface Box 100X100 X75 Mm ( Inside ) With Hinged Cover Fixed In Cement Concrete Slab 1:2:4 Mix ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size ) , I / C Necessary Excavation, Foundation Concrete 1:5:10 ( 1 Cement : 5 Fine Sand : 10 Graded Stone Aggregate 40Mm Nominal Size ) And Inside Plastering With Cement Mortar 1:3 ( 1 Cement : 3 Coarse Sand ) 12Mm Thick, Finished With A Floating Coat Of Neat Cement Complete As Per Standard Design.With Common Burnt Clay F.P.S. ( Non Modular ) Bricks Of Class Designation 7.5. , Full Way Valve Chamber , Supplying Materials , Labours And Equipments For Construction Of 0.90M X 0.90 M Size P.C.C. ( 1:2:4 ) Rectangular Platform With Stand Post In House Including 12 Mm Thick Cement Plaster In C.M. ( 1:4 ) With Neat Cement Punning Over Exposed Surfaceall Complete Job, As Per Approved Design, Specification And Direction Of E / I. , Providing Brick Masonry Chamber Ofinner Size 600 X 600 X 450 Mm Deep For Bore Well Protection Having 125 Mm Thick Wall And 75 Mm R.C.C Cover Including Cement Plaster Of Exposed Surface, Etc All Complete Job. , Earth Work In Back Filling The Trenches After Laying Different Types And Size Of Pipes With Earth Removed During Excavation Within Initial Lead And Lift As Per Specification And Direction Of Engineer-In-Charge. , Providing Fitting & Fixing 32 Mm To 50 Mm Service Hdpe Saddleall Complete Job, As Per Approved Design, Specification And Direction Of E / I. , Carriage Of Materials From Different Sources Or Departmental Stores To Work Site Including Loading, Transporting, Unloading And Stacking The Materials At Work Site Etc. All Complete Job. As Per Direction Of E / I. , Cement Lead 10 Km ( Avg. ) , Sand Lead 36 Km ( Avg. ) , Stone Chips Lead 11 Km ( Avg. ) , Steel Reinforcement Lead 10 Km ( Avg. ) , Bricks Lead 06 Km ( Avg. ) , Annual Operation & Maintenance Cost Based On Existing D / T Well With Solarmotor Pump For 5 Years , O & M Cost For 1St Year , O & M Cost For 2Nd Year , O & M Cost For 3Rd Year , O & M Cost For 4Th Year , O & M Cost For 5Th Year , Provision Of One No Sim Card & Its Recharging Cost For Rmc , Model-1B With Source ( Drilled T / W 125 / 115Dia Mm, 60M Deep ) , Tube Well , Drilling Portion , Construction For 115 / 125 Mm Dia Drilled Tube-Well For Drilling In All Kinds Of Soil Rock For Installation Of Hand Pump With D.T.H Rig Machine All Complete Including Supplying All Materials, Labours, Tools, Drilling, Rigs, Air Compressor And Equipments As Well As Fuel Lubricant For Making 125 / 115 Mm Dia Boring Etcand Cost Of Transporting Rig Machine And Other Vehicle Up To Site Workas Per Specification And Direction Of Engineer-In-Charge. , ( A ) Up To 30Mtr. Depth Bellow G.L. In Rural Areas , ( B ) Beyond 30Mtr.In Rural Areas , Providing All Equipments And Labour For Lowering 125Mm Dia Blue Upvc Casing Pipe As Casing For Protecting The Side From Falling During The Process Of Drilling All Complete Job Including Carriage Of Material To Work Site. , Supplying Labour Cement And Calcium Chloride Or Bentonite Solution And Equipments For Grouting To Casing Pipe All Complete Job Including Carriage Of Material To Work Site As Per Specification & Direction Of E / I , Supplying All Tools, Equipments And Labour And Doing Washing, Flushing And Development Of Drilled Tube Well To Give Clean And Clear Water All Complete As Per Direction E / I. , Supplying All Materials Labours And Equipment Including 125 Mm Dia Gi / Ci Cap 125 Mm Dia T / W Properly All Complete And Taking It Out As Per Specification & Direction Of E / I. ( The Cap Will Be Property Of Department ) , Civil Portion , Supplying All Tools, Equipment, Labours And Lowering 32 Mm Dia G.I. ( Medium ) Pipe In Dt In 3 Mtr. Length All Complete Job As Per Direction Of E / I. Including Carriage Of Materials. , Supplying All Tools, Labour For Fitting And Fixing Deep Well Cylinder With Necessary Connecting Rod All Complete Job As Per Specification & Direction Of E / I. , Supplying All Materials, Labours For Fitting And Fixing Of India Mark Ii Hand Pump With All Accessories All Job Complete As Per Direction Of E / I. Including Carriage Of Materials. , Supplying All Materials, Labours And Equipment For Constructing Pcc ( 1:2:4 ) Circular Platform Around Each Drilled Tube Well Including 12Mm Thick Cement Plaster ( 1:4 ) With Neat Cement Punning Over Exposed Surface As Per Unicef Design Etc. All Complete. Including Carriage Of Materials. , Supplying All Materials Labour And Equipment For Constructing Pcc ( 1:2:4 ) Drain As Per Unicef Design Etc. All Complete .Including Carriage Of Materials. , Add Extra Item For Supplying Tools, Labours And Materials For Painting, Numbering And Year For Construction Of T / Well And Taking Of Colour Photograph With Two Or Three Nearest Persons Including Platform, Drain, Soak Pit And Also Longitude & Latitude, Details Of T / W Such As Total Depth, Casing Depth, Static Water Level, Drawdown, Discharge, Strata Chart, Beneficiary Population Etc In Separate Sheet / Format All Complete As Per Direction Of E / I. , Cost Of Materials , Cost Of Standard I.S.I. Mark Deep Well Hand Pump For India Mark-Ii, I.S.I. 15500 ( Part 2 ) / 2004 With Latest Revision Including 12Mm X 3 Meter Long 8 No. Connecting Rods Made Of Bright Bar Electro-Galvanized Fitted With Coupler & Normal Stand Assembly Recommended For Use With Cylinder Assembly Suitable For Bore Wellcasing Pipe. , Cost Of 32 Mm Dia Gi Pipe ( Medium ) 3 Mtrs Long Screwed At Both Ends With Seamless Socket As Per Is:1239 ( Part 1990 ) . , Cost Of 125 Mm Dia Blue Upvc Casing Pipe As Per I.S.12818 / 2016 Cml No.- 5543459 , Rcc Foundation For Steel Structurestaging& Solar Panel , Earth Work In Excavation In Foundation Trenches In Ordinary Soil And Disposal Of Excavated Earth As Obtained To A Distance Up To 50.0M , Including All Lifts, Levelling , Ramming The Foundation Trenches, Removing Roots Of Trees, Shrubs All Complete As Per Approved Design , Building Specification And Direction Of E / I ( Vide Classification Of Soil Item -B ) , Providing Coarse Clean Sand In Filling In Foundation Trenches Or In Plinth Including Ramming And Watering In Layers Not Exceeding 150Mm Thick With All Leads And Lifts Including Cost Of All Materials , Labour , Royalty And Taxes All Complete As Per Building Specification And Direction Of E / I , Providing Designation 75 A One Brick Flat Soling Joints Filled With Local Sand Including Cost Of Watering Taxes Royalty All Complete As Per Building Specification And Direction Of E / I , Providing Nominal Mix Pcc Of ( 1:4:8 ) In Foundationwith Approved Quality Of Stone Chips 20Mm To 6Mm Size Graded And Clean Coarse Sand Of F.M.2.5To 3 Including Screening Shuttering Mixing Cement Concrete In Mixer And Placing In Position Vibrating Striking Curing And Royalty All Complete As Per Building Specification And Direction Of E / I , Providing Rcc M-20 In Nominal Mix Of ( 1:1.5:3 ) In Columnswith Approved Quality Of Stone Chips 20Mm To 6Mm Size Graded And Clean Coarse Sand Of F.M.2.5To 3 Including Screening Shuttering Mixing Cement Concrete In Mixer And Placing In Position Vibrating Striking Curing And Royalty All Complete As Per Building Specification And Direction Of E / I. , ( A ) Foundation For Steel Structure Staging , Footing And Vertical Pedestal Raft , Column , Tie Beam , ( B ) Foundation For Solar Panel , Footing , Vertical Pedestal , Providing For Steel Reinforcement As Per Approved Design And Drawing Excluding Carriage Of T.S. Bar To Work Site Cutting, Bending With Annealed Wire With Cost Of Wire, Removal Of Rust Placing The Rods In Position All Complete As Per Building Specification And Direction Of E / I. , ( A ) Foundation For Steel Structure Staging , Carriage Of Materials From Different Sources Or Departmental Stores To Work Site Including Loading, Transporting, Unloading And Stacking The Materials At Work Site Etc. All Complete Job. As Per Direction Of E / I. , Cement Lead 10 Km ( Avg. ) , Sand Lead 36 Km ( Avg. ) , Stone Chips Lead 11 Km ( Avg. ) , Steel Reinforcement Lead 10 Km ( Avg. ) , Bricks Lead 06 Km ( Avg. ) , Galvanized Tubular Steel Structure Staging Forhdpe Water Storage Tank& Solar Panel , Providing Structural Steel Galvanisedsqure Pipe Section Work In Trusses, Other Similar Trussed Purlins And Members With All Bracing , Gusset Plates Etc As Per Detailed Design And Drawing Or As Directed By Engineer- In-Charge , Including Cutting Fabricating , Hoisting , Erecting And Fixing In Position , Making Riveted / Bolted / Welded Connections And One Coat Of Anticorrosive Paint And Over It Two Coat Of All Oil Painting & For Structure ( Plus ) Providing And Applying Materials &Labour For Hot Dip Galvanizing Of Above Structure Including Transportation For Galvanizing Minimum Thickness 80Microns ( Net Wt. Of Components To Be Galv ) Preferably Tata Structural Section Etc Complete. , Hardware ( L.S. ) , Information Board For Iec , Providing Structural Steel Work In Trusses Other Similar Trussed Purlins And Members With Bracing Gusset Plates Etc As Per Detailed Design And Drawing Or As Directed By Engineer- In-Charge Including Cutting Fabricating Hoisting Erecting And Fixing In Position Making Reverted Bolted Welded Connections One Coat Of Anticorrosive Paint And Over It Two Coats Of Oil Painting Etc Complete , Installation Of 5000 Liters Capacity Water Storage Tank , Providing And Fixing Hdpe Container Syntex Or Alike One Piecemolded Water Tank Made Out Of Low Density Polythyler Andbuilt Corrugation Including Of Delivery Up To Destination Hoisting And Fixing Of Accessories Such As Inlet, Outlet Overflow Of All Tanks Capacity 5000.00 Litres Capacity Water Storage Tank , Transportation Charge , Lifting Of 5000 Litrs Capacity Tank Up To 4.00M Height With Lifting Tools With Rope And Labour , Making Hole In Tank , Making Long Screw In G.I. Pipe Including Supplying And Fitting Jam Nuts And Extra Socket Etc. , Rising And Distribution Network With House Connection Up To 20 Nos. Including Platform & Stand Post , Earth Work In Excavation In Foundation Trenches In Hard Soil ( Vide Classification Soil Item B ) And Disposal Of Excavated Earth As Obtained To A Distance Up To 50 Mtr. Including All Lifts, Leveling, Ramming The Foundation Trenches, Removing Roots Of Trees, Shrubs All Complete As Per Approved Design, Specification And Direction Of E / I. , Dismantling Plain Cement Concrete Work Including Stacking Serviceable Materials In Countable Stacks Within 15 M Lead And Disposal Of Unserviceable Materials With All Leads All Complete , Providing Pccm-200 With Nominal Mix Of ( 1:1.5:3 ) With Approved Quality Of Stone Chips 20 Mm To 6 Mm Size Graded And Clean Coarse Sand Of Fm 2.5 To 3.0 Including Screening, Shuttering, Mixing Cement Concrete In Mixer And Placing In Position, Vibrating, Sticking, Curing , Taxes And Royalty All Complete As Per Specification And Direction Of E / I. For Construction Of Road Cutting Portion , Rising Main , Manufacture, Supply And Delivery Offollowing Nominal Dia Upvc Column Pipes Including Pvc Socket ( Coupler ) , , 65Mm Dia -Density Of Pipe 1.38 To 1.43 Gm Per Cm3 Od:74.5 To 75.2Mm Wall Thickness End:9Mm To 10.7Mm, Barrel 9Mm To 10.7 Mm, Length: 3Mtrs.Rising Main , 50 Mm Dia -Density Of Pipe 1.38 To 1.43 Gm Per Cm3 Od:87.5 To 88.2Mm Wall Thickness End:9 .8 Mm To 11.9Mm, Barrel 7.3Mm To 9 Mm, Length: 3Mtrs. Delivery Pipe , Distribution , Providing And Supplying High Density Polyethylene Pipe ( Hdpe Pipe ) Of 20 Mm To 225 Mm Od And Pressure 6.0 Kg / Cm2 And 10 Kg / Cm2 Suitable For Water Supply Which Is Available In All Standard Conforming To Isi -- 4984 / 14151 / 12786 / 13488, Iso 4427 , Din-8074Materials Rates Are Ex-Factory Excluding Transportation, Taxes And Duties. , 63 Mm Hdpe Pipe , 50 Mm Hdpe Pipe , 32 Mm Hdpe Pipe , 20 Mm Hdpe Pipe , Providing And Fixing Gun Metal Gate Valvewith C I Wheel Of Approved Quality ( Screwed End ) . , 65 Mm Dia , 50Mm Dia , Providing And Supplying High Density Polyethylene ( Hdpe ) Fittings Of 20 Mm To 225 Mm Od And Pressure 6.0 Kg / Cm2 And 10 Kg / Cm2 Suitable For Water Supply Which Is Available In All Standard Conforming To Isi -- 4984 / 14151 / 12786 / 13488, Iso 4427 , Din-8074Materials Rates Are Ex-Factory Excluding Transportation, Taxes And Duties. , Lowering, Laying And Jointing H. D. P. E. / M. D.P. E. Pipes In Proper Position Including All Specials By Compression Fitting / Electro Fusion And Butt Fusion Jointing Procedure As Per Relevant Is Code Complete With All Materials For Jointing Procedure Like Electro Fusion Machine, Electric Heater / Butt Fusion Welding Machine With Hydraulic Jack, Top Loading Clamp Etc. And All Labours As Directed By Engineer In Charge As Per Is-7634 Part Ii. , For Rising , 50 Mm Hdpe Pipe , 65 Mm Hdpe Pipe , Distribution , 65 Mm Hdpe Pipe , 50 Mm Hdpe Pipe , 32 Mm Hdpe Pipe , 20 Mm Hdpe Pipe , Providing 15 Mm Dia. G.I. Pipe Tata Or Equivalent Make As Per Is 1239 ( Part 1 / 2004 ) Isi Mark / Medium Quality In Stand Post. , Supplying All Materials , Labour And Tools For Fixing 15 Mm Dia G.I. Pipes With Red Lead And Yarn Of Following Nominal Bore With Screwed And Socketed Joints On Wall, Ceiling And Floor Including Supplying And Fitting Of Wall Hooks Or Pipe Clamps, Wooden Plugs, Cutting Pipes To Size And Threading Ends If Required Etc. All Complete As Per Specification And Direction Of Engineer-In-Charge. , Supplying And Fixing G.I. Fittings Of Approved Make All Complete As Per Specification And Direction Of E / I. , Elbow 15 Mm Dia. , Reducer Socket 20X15 Mm Dia. , Nipple 15 Mm Dia. , Plain Socket 15 Mm Dia. , Supplying And Fixing G.M. Ferrule Of Approved Make In Existing C.I. / D.I. Main Including Drilling And Taping C.I. / D.I. Main All Complete As Per Specification And Direction Of E / I. 3 Mm, 6 Mm 10 Mm Dm Ferrule Weight Not Less Than 425 Gram. , Providing And Fixing Gun Metal Full Way Valve Of Approved Quality, All Complete, As Per Specification And Direction Of E / I. , 65 Mm Dia Full Way Valve , 50 Mm Dia And Weight Not Less Than 1.5 Kg. , Providing And Fixing Of Male Ended C.I.Body Brass Spindle Valve And Seat Bib Cock Of Approved Quality With Extra Socketall Complete As Per Specification And Direction Of E / I. , 15 Dia And Weight Not Less Than 400 Gm , Constructing Masonry Chamber 30X30x50 Cm Inside, In Brick Work In Cement Mortar 1:4 ( 1 Cement :4 Coarse Sand ) For Stop Cock, With C. I. Surface Box 100X100 X75 Mm ( Inside ) With Hinged Cover Fixed In Cement Concrete Slab 1:2:4 Mix ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size ) , I / C Necessary Excavation, Foundation Concrete 1:5:10 ( 1 Cement : 5 Fine Sand : 10 Graded Stone Aggregate 40Mm Nominal Size ) And Inside Plastering With Cement Mortar 1:3 ( 1 Cement : 3 Coarse Sand ) 12Mm Thick, Finished With A Floating Coat Of Neat Cement Complete As Per Standard Design.With Common Burnt Clay F.P.S. ( Non Modular ) Bricks Of Class Designation 7.5. Full Way Valve Chamber , Supplying Materials , Labours And Equipments For Construction Of 0.90M X 0.90 M Size P.C.C. ( 1:2:4 ) Rectangular Platform With Stand Post In House Including 12 Mm Thick Cement Plaster In C.M. ( 1:4 ) With Neat Cement Punning Over Exposed Surfaceall Complete Job, As Per Approved Design, Specification And Direction Of E / I. , Providing Brick Masonry Chamber Ofinner Size 600 X 600 X 450 Mm Deep For Bore Well Protection Having 125 Mm Thick Wall And 75 Mm R.C.C Cover Including Cement Plaster Of Exposed Surface, Etc All Complete Job , Earth Work In Back Filling The Trenches After Laying Different Types And Size Of Pipes With Earth Removed During Excavation Within Initial Lead And Lift As Per Specification And Direction Of Engineer-In-Charge. , Providing Fitting & Fixing 32 Mm To 50 Mm Service Hdpe Saddleall Complete Job, As Per Approved Design, Specification And Direction Of E / I. , Carriage Of Materials From Different Sources Or Departmental Stores To Work Site Including Loading, Transporting, Unloading And Stacking The Materials At Work Site Etc. All Complete Job. As Per Direction Of E / I. , Cement Lead 10 Km ( Avg. ) , Sand Lead 36 Km ( Avg. ) , Stone Chips Lead 11 Km ( Avg. ) , Steel Reinforcement Lead 10 Km ( Avg. ) , Bricks Lead 06 Km ( Avg. ) , Solar Photovoltaic ( Spv ) Solar Submersible D.C. Water Motor Pump , Designing, Supplying, Installation, Testing & Commissioning With All Tools & Parts Of Following Solar Photovoltaic ( Spv ) Solar Submersible D.C. Water Motor Pump Suitable For Minimum 125Mm X 115Mm Bore Well As Per Mnre Guideline With Following Specifications & Accessories. , Spv Arrays Contains Specified No Of Same Capacity Type & Specification Modules Connected To Series Or Parallel To Obtained The Required Voltage & Current The Power Output Of Individual Pvmodules Should Be Minimum 200 Watt Peak. , I ) The Spv Modules Should Be As Per Iec-61215 And Iec 61730 Part 1.0 ) , Ii ) All External Parts Of Motor Pump Used In Submersible Pump Which Are In Contact Of Water Is Stainless Steel Grade 303 Or Higher As Required. , Iii ) The Pv Modules Shouldbe Mounted On Metallic Structure Of Adequate Strength And Appropriate Design Which Can Withstand Load Of Modules & High Wind Pressure Up To 200Km / H. , Iv ) The Module Mounting Structure Should Be Hot Dip Galvanized According To Is 4759. , V ) To Enhance The Performance Of Spv Water Pumping System & Arrangement For Seasonal Tilt Angle Adjustment Should Be Provided , Vi ) Necessary Arrangement Should Be Provided In Controller Automatic Start-Run-Stop Through Out The Day With Water Level Detection System. ( As Per Mnre Specification ) , Vii ) Necessary Protection Such As Lightening Arrestor Etc. Should Be Provided To Protect The Controller & Spv , Viii ) The Suction / Delivery Pipe Shall Be Upvc / H.D.P.E. Pipes Of Appropriate Size 60M Or More As Required Minimum Pressure Rating Of 8Kg / Sq Cm- Pe 100 Grade For Pump Up To 3Hp & 10 Kg / Sq Cm- Pe 100 Grade For 5 Hp. , Ix ) All Cable Used Shall Be As Per Is 694. Suitable Size Of Cable Shall Be Used In Sufficient Length For Inter Connection Between The Spv Array To Spv Controller And Spv Controller To Solar Power Pump. Provision Of Cable Shall Be As Per Is 14536. , X ) The Motor Pump Set Should Have A 5 Years Warranty. , Xi ) Control Panel Suitable For Motor Pump With Arrangement Of Dry Run & Over Flow Protection Sensor, Float Switch & Rain Prevention Box. ( As Per Mnre Specification ) , Xii ) The Spv Controller Must Have Ip-65 Protection Or Must Be Housed In Cabinet Having At Least Ip-65 Protection. , Xiii ) The System Should Be As Per Mnre Guide Line & Eco-Friendly With Suitable Arrangement To Operate New Pump Manually. , Xiv ) With Third Party Inspection Before Dispatch. , Xv ) Provision For Web Basedremote Monitoring Of The Pumps To Be Installed Must Be Made Through The Inbuilt Controllers . It Should Be Possible To Ascertain The Daily Water Output, The Power Generated By Pv Array , The Up And Downtime Of The Pump During The Year, Number Of Days The Pump Was Unused Or Under Breakdown Repairs. , The Following Details Should Be Marked Indelibly On The Motor Pump Set , A ) Name Of The Manufacturer Or Distinctive Logo. , B ) Model Number. , C ) Serial Number. , Solar Submersible Motor Pump ( Spv Dc Type ) , I ) 1 Hp ( Dc Pump ) With 900 Wp Minimum Watt P.V. Panel As Mnre Pump Head Max Shut-Off Head Up To 120 Mtrs. For Higher Or Lower Head Or In Between Various Modules Output Could Be Decided On Prorates Basis. ( As Per Latest Guide Line Of Mnre ) , Carrying Out Recuperation / Yield Test For Ascertaining The Discharge Of Constructed Well / Excavated Profile As Directed By The Iec. The Testout By The Drawing Down Water From The Well / Profile Below Normal / Subsoil Water Level Up To Full Depth Rise Is Recorded The Normal Water Level / Subsoil Water Level In The Well / Profile As Well As Strainer / Level At Pump As Per Design Of W.S. Scheme Shall Be Recorded Prior To The Test Including Cost Of All Materials, Over Load , Labours Etc. Complete As Directed. , Supplying All Labours, Tools And Equipments For Dismantling Of Head & Water Tank Assembly And Taking Out 32 Mm Dia Old G.I. Pipe, Connecting Rod, Cylinder Assembly The Dismantled Components After Necessary Changing For Making The T / W In Good Condition With All Transportation Including Unused Taken Out Materials Back In Store All Complete Job As Per Direction Of E / I. ( As Per Model Estimate Of Solar Energy Based Mini Wss. Ts Done By Se, Ranchi Circle & Circle Gumla Dt. 21.05.2019 ) , Provision Of Solar Night Lamp. , Galvanised Chain-Line Mess Fencing Around Solar Panel Where Bore Well Is Away From Tower , Making 30 Cm ( 12 ) Dia Bore Up To 4M Below Ground With Hand Auger Of Approved Quality In Ordinary Soil ( Vide Classification Of Soil Item-A ) True To Plum And Without Eccentricity In Any Stage Of Operation And Disposal Of The Exacavated Earth Up To 50M Lead Including All Lifts All Complete As Per Approved Design And Direction Of E / I. , Providing Pcc M-150 In Nominal Mix Of ( 1:2:4 ) In Foundationwith Approved Quality Of Stone Chips 20Mm To 6Mm Size Graded And Clean Coarse Sand Of F.M.2.5 To 3 Including Screening Shuttering, Mixing Cement Concrete In Mixer And Placing In Position, Vibrating, Curing, Taxes And Royalty All Complete As Per Building Specification Direction Of E / I. , Labour Cost Of Fitting And Fixing Galvanised Chain-Link Mess Up Height Of 2 M Including Cost Of Staples ( But Excluding The Cost Of Cement Concete Angle Iron Posts, Its Cutting And Making Holes, Nuts And Bolts ) All Complete As Per Specification And Direction Of E / I. , Drilling 6Mm Dia Holes In M.S Angle Iron For Fixing Of Stables Etc. As Per Building Specification And Direction Of E / I. , Labour Cost Cutting Of M.S Angle Iron Posts To Required Length, One End Splitted As Fish Tailed In A Length Of 150Mm Complete As Per Building Sepcification And Direction Of E / I. , Supplying, Fitting And Fixing Straining Bolts With Nut Size 22Cm*10Mm Dia Tighten The Barbed Wire With Corner Post Complete As Per Building Specification And Direction Of E / I. , Supplying, Fitting And Fixing Galvanised Chain -Link Mess Having 3Mm Thick Wire Cell Type 40 X 40 Mm Fitted On M.S. Angle Frame With Two Diagonals Having 25X25x5mm Size Angle Including Cost Of Fabrication, Providing Necessary Bocking Arrangement With Haskal And Domny Duly Fixed In Angle Post, Applying A Priming Red Lead Paint Over Steel Work, Taxes Excluding The Cost Of Galvanised Chain-Link Mess All Complete. , Cost Of Galvanised Chain-Link Mess Having 3 Mm Thick Wire Cell Type 40X40 Mm Not Less Than 3.1 Kg / Sqm , Cost Of 50 X 50 X 6 Mm M.S Angle , Carriage Of Materials From Different Sources Or Departmental Stores To Work Site Including Loading, Transporting, Unloading And Stacking The Materials At Work Site Etc. All Complete Job. As Per Direction Of E / I. , Cement Lead 10 Km ( Avg. ) , Sand Lead 36 Km ( Avg. ) , Stone Chips Lead 11 Km ( Avg. ) , Steel Reinforcement Lead 10 Km ( Avg. ) , Annual Operation & Maintenance Cost Based On Existing D / T Well With Solarmotor Pump For 5 Years , O & M Cost For 1St Year ( Excluding Repair Charges ) , O & M Cost For 2Nd Year With Annual Repair Charges , O & M Cost For 3Rd Year , O & M Cost For 4Th Year , O & M Cost For 5Th Year , Provision Of One No Sim Card & Its Recharging Cost For Rmc , 18% Gst , Labour Cess
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 6
33.
Drinking Water Supply and Sanitation #9062055 Technical Bid
Const Of Solar Based Mrwss Svs In Pirtand Block, Comprising Of Suitable R.C.C Framed Structure Esr Distribution Lines, Source (As Required) And Fhtc All Complete Under Drinking Water Sanitation Division No 2 Giridih Cluster No 37 , Model-1Awith Source(Drilled T/W 125/115 Dia Mm, 60M Deep) , Tube Well , Drilling Portion , Construction For 115/125 Mm Dia Drilled Tube-Well For Drilling In All Kinds Of Soil Rock For Installation Of Hand Pump With D.T.H Rig Machine All Complete Including Supplying All Materials, Labours, Tools, Drilling, Rigs, Air Compressor And Equipments As Well As Fuel Lubricant For Making 125/115 Mm Dia Boring Etcand Cost Of Transporting Rig Machine And Other Vehicle Up To Site Workas Per Specification And Direction Of Engineer-In-Charge. , (A) Up To 30Mtr. Depth Bellow G.L. In Rural Areas , (B) Beyond 30Mtr.In Rural Areas , Providing All Equipments And Labour For Lowering 125Mm Dia Blue Upvc Casing Pipe As Casing For Protecting The Side From Falling During The Process Of Drilling All Complete Job Including Carriage Of Material To Work Site. , Supplying Labour Cement And Calcium Chloride Or Bentonite Solution And Equipments For Grouting To Casing Pipe All Complete Job Including Carriage Of Material To Work Site As Per Specification & Direction Of E/I , Supplying All Tools, Equipments And Labour And Doing Washing, Flushing And Development Of Drilled Tube Well To Give Clean And Clear Water All Complete As Per Direction E/I. , Supplying All Materials Labours And Equipment Including 125 Mm Dia Gi/Ci Cap 125 Mm Dia T/W Properly All Complete And Taking It Out As Per Specification & Direction Of E/I. (The Cap Will Be Property Of Department) , Civil Portion , Supplying All Tools, Equipment, Labours And Lowering 32 Mm Dia G.I. (Medium)Pipe In Dt In 3 Mtr. Length All Complete Job As Per Direction Of E/I. Including Carriage Of Materials. , Supplying All Tools, Labour For Fitting And Fixing Deep Well Cylinder With Necessary Connecting Rod All Complete Job As Per Specification & Direction Of E/I. , Supplying All Materials, Labours For Fitting And Fixing Of India Mark Ii Hand Pump With All Accessories All Job Complete As Per Direction Of E/I. Including Carriage Of Materials. , Supplying All Materials, Labours And Equipment For Constructing Pcc (1:2:4) Circular Platform Around Each Drilled Tube Well Including 12Mm Thick Cement Plaster (1:4) With Neat Cement Punning Over Exposed Surface As Per Unicef Design Etc. All Complete. Including Carriage Of Materials. , Supplying All Materials Labour And Equipment For Constructing Pcc (1:2:4) Drain As Per Unicef Design Etc. All Complete .Including Carriage Of Materials. , Add Extra Item For Supplying Tools, Labours And Materials For Painting, Numbering And Year For Construction Of T/Well And Taking Of Colour Photograph With Two Or Three Nearest Persons Including Platform, Drain, Soak Pit And Also Longitude & Latitude, Details Of T/W Such As Total Depth, Casing Depth, Static Water Level, Drawdown, Discharge, Strata Chart, Beneficiary Population Etc In Separate Sheet/Format All Complete As Per Direction Of E/I. , Cost Of Materials , Cost Of Standard I.S.I. Mark Deep Well Hand Pump For India Mark-Ii, I.S.I. 15500 (Part 2) / 2004 With Latest Revision Including 12Mm X 3 Meter Long 8 No. Connecting Rods Made Of Bright Bar Electro-Galvanized Fitted With Coupler & Normal Stand Assembly Recommended For Use With Cylinder Assembly Suitable For Bore Wellcasing Pipe. , Cost Of 32 Mm Dia Gi Pipe (Medium) 3 Mtrs Long Screwed At Both Ends With Seamless Socket As Per Is:1239(Part 1990). , Cost Of 125 Mm Dia Blue Upvc Casing Pipe As Per I.S.12818/2016 Cml No.- 5543459 , Solar Photovoltaic (Spv) Solar Submersible D.C. Water Motor Pump , Designing, Supplying, Installation, Testing & Commissioning With All Tools & Parts Of Following Solar Photovoltaic (Spv) Solar Submersible D.C. Water Motor Pump Suitable For Minimum 125Mm X 115Mm Bore Well As Per Mnre Guideline With Following Specifications & Accessories. , Spv Arrays Contains Specified No Of Same Capacity Type & Specification Modules Connected To Series Or Parallel To Obtained The Required Voltage & Current The Power Output Of Individual Pvmodules Should Be Minimum 200 Watt Peak. , I) The Spv Modules Should Be As Per Iec-61215 And Iec 61730 Part 1.0) , Ii) All External Parts Of Motor Pump Used In Submersible Pump Which Are In Contact Of Water Is Stainless Steel Grade 303 Or Higher As Required. , Iii) The Pv Modules Shouldbe Mounted On Metallic Structure Of Adequate Strength And Appropriate Design Which Can Withstand Load Of Modules & High Wind Pressure Up To 200Km/H. , Iv) The Module Mounting Structure Should Be Hot Dip Galvanized According To Is 4759. , V) To Enhance The Performance Of Spv Water Pumping System & Arrangement For Seasonal Tilt Angle Adjustment Should Be Provided , Vi) Necessary Arrangement Should Be Provided In Controller Automatic Start-Run-Stop Through Out The Day With Water Level Detection System. (As Per Mnre Specification) , Vii) Necessary Protection Such As Lightening Arrestor Etc. Should Be Provided To Protect The Controller & Spv , Viii) The Suction/Delivery Pipe Shall Be Upvc / H.D.P.E. Pipes Of Appropriate Size 60M Or More As Required Minimum Pressure Rating Of 8Kg/Sq Cm- Pe 100 Grade For Pump Up To 3Hp & 10 Kg/Sq Cm- Pe 100 Grade For 5 Hp. , Ix) All Cable Used Shall Be As Per Is 694. Suitable Size Of Cable Shall Be Used In Sufficient Length For Inter Connection Between The Spv Array To Spv Controller And Spv Controller To Solar Power Pump. Provision Of Cable Shall Be As Per Is 14536. , X) The Motor Pump Set Should Have A 5 Years Warranty. , Xi) Control Panel Suitable For Motor Pump With Arrangement Of Dry Run & Over Flow Protection Sensor, Float Switch & Rain Prevention Box. (As Per Mnre Specification) , Xii) The Spv Controller Must Have Ip-65 Protection Or Must Be Housed In Cabinet Having At Least Ip-65 Protection. , Xiii) The System Should Be As Per Mnre Guide Line & Eco-Friendly With Suitable Arrangement To Operate New Pump Manually. , Xiv) With Third Party Inspection Before Dispatch. , Xv) Fitting, Fixing & Mounting On Water Tank Steel Structure. , Xvi) Provision For Web Basedremote Monitoring Of The Pumps To Be Installed Must Be Made Through The Inbuilt Controllers . It Should Be Possible To Ascertain The Daily Water Output, The Power Generated By Pv Array ,The Up And Downtime Of The Pump During The Year, Number Of Days The Pump Was Unused Or Under Breakdown Repairs. , The Following Details Should Be Marked Indelibly On The Motor Pump Set , A) Name Of The Manufacturer Or Distinctive Logo. , B) Model Number. , C) Serial Number. , Solar Submersible Motor Pump (Spv Dc Type) , I) 1 Hp (Dc Pump) With 900 Wp Minimum Watt P.V. Panel As Mnre Pump Head Max Shut-Off Head Up To 120 Mtrs. For Higher Or Lower Head Or In Between Various Modules Output Could Be Decided On Prorates Basis. (As Per Latest Guide Line Of Mnre) , Carrying Out Recuperation/Yield Test For Ascertaining The Discharge Of Constructed Well/ Excavated Profile As Directed By The Iec. The Testout By The Drawing Down Water From The Well/ Profile Below Normal/Subsoil Water Level Up To Full Depth Rise Is Recorded The Normal Water Level/Subsoil Water Level In The Well / Profile As Well As Strainer/Level At Pump As Per Design Of W.S. Scheme Shall Be Recorded Prior To The Test Including Cost Of All Materials, Over Load , Labours Etc. Complete As Directed. , Supplying All Labours, Tools And Equipments For Dismantling Of Head & Water Tank Assembly And Taking Out 32 Mm Dia Old G.I. Pipe, Connecting Rod, Cylinder Assembly The Dismantled Components After Necessary Changing For Making The T/W In Good Condition With All Transportation Including Unused Taken Out Materials Back In Store All Complete Job As Per Direction Of E/I. , Provision Of Solar Night Lamp. , Construction Rcc Foundation For Steel Structurestaging& Solar Panel , Earth Work In Excavation In Foundation Trenches In Ordinary Soil And Disposal Of Excavated Earth As Obtained To A Distance Up To 50.0M ,Including All Lifts, Levelling ,Ramming The Foundation Trenches, Removing Roots Of Trees, Shrubs All Complete As Per Approved Design ,Building Specification And Direction Of E/I (Vide Classification Of Soil Item -B) , Providing Coarse Clean Sand In Filling In Foundation Trenches Or In Plinth Including Ramming And Watering In Layers Not Exceeding 150Mm Thick With All Leads And Lifts Including Cost Of All Materials ,Labour ,Royalty And Taxes All Complete As Per Building Specification And Direction Of E/I(Mode Of Measurement Compacted Volume) , Providing Designation 75 A One Brick Flat Soling Joints Filled With Local Sand Including Cost Of Watering Taxes Royalty All Complete As Per Building Specification And Direction Of E/I , Providing Pcc M-150 In Nominal Mix Of (1:2:4) In Foundationwith Approved Quality Of Stone Chips 20Mm To 6Mm Size Graded And Clean Coarse Sand Of F.M.2.5To 3 Including Screening Shuttering Mixing Cement Concrete In Mixer And Placing In Position Vibrating Striking Curing And Royalty All Complete As Per Building Specification And Direction Of E/I , Providing Rcc M-200 In Nominal Mix Of (1:1.5:3) In Columnswith Approved Quality Of Stone Chips 20Mm To 6Mm Size Graded And Clean Coarse Sand Of F.M.2.5To 3 Including Screening Shuttering Mixing Cement Concrete In Mixer And Placing In Position Vibrating Striking Curing And Royalty All Complete As Per Building Specification And Direction Of E/I. , (A)Foundation For Steel Structure Staging , Footing , Vertical Pedestal , Tie Beam , (B)Foundation For Solar Panel , Footing , Vertical Pedestal , Providing For Steel Reinforcement As Per Approved Design And Drawing Excluding Carriage Of T.S. Bar To Work Site Cutting, Bending With Annealed Wire With Cost Of Wire, Removal Of Rust Placing The Rods In Position All Complete As Per Building Specification And Direction Of E/I. , 10 Mm Dia , 12 Mm Dia , Carriage Of Construction Materials To Work Site Including Loading, Unloading & Stacking Etc. All Complete. , Cement10km Lead , Steel10km Lead , Stone Chips 11Km Lead , Sand36km Lead , Bricks 06Km Lead , Construction Ofgalvanized Tubular Steel Structure Staging For (4.5M) Hdpe Water Storage Tank& Solar Panel. , Providing Structural Steel Galvanised Tubular Hollow Section Work In Trusses, Other Similar Trussed Purlins And Members With All Bracing ,Gusset Plates Etc As Per Detailed Design And Drawing Or As Directed By Engineer- In-Charge ,Including Cutting Fabricating ,Hoisting , Erecting And Fixing In Position , Making Riveted/Bolted /Welded Connections And One Coat Of Anticorrosive Paint And Over It Two Coat Of All Oil Painting & For Structure(Plus) Providing And Applying Materials &Labour For Hot Dip Galvanizing Of Above Structure Including Transportation For Galvanizing Minimum Thickness 80Microns (Net Wt. Of Components To Be Galv) Preferably Tata Structural Section Etc Complete. , Providing Structural Steel Work In Trusses Other Similar Trussed Purlins And Members With Bracing Gusset Plates Etc As Per Detailed Design And Drawing Or As Directed By Engineer- In-Charge Including Cutting Fabricating Hoisting Erecting And Fixing In Position Making Reverted Bolted Welded Connections One Coat Of Anticorrosive Paint And Over It Two Coats Of Oil Painting Etc Complete. , Materials And Labour For Vinyl Painting Of Matter Given By Department In Different Color , Installation Of 2000 Liters Capacity Water Storage Tank , Providing And Fixing Hdpe Container Syntex Or Alike One Piecemolded Water Tank Made Out Of Low Density Polythyler Andbuilt Corrugation Including Of Delivery Up To Destination Hoisting And Fixing Of Accessories Such As Inlet, Outlet Overflow Of All Tanks Capacity 2000.00 Litres Capacity Water Storage Tank , Transportation Charge , Lifting Of 2000 Litrs Capacity Tank Up To 4.5M Height With Lifting Tools With Rope And Labour , Making Hole In Tank , Making Long Screw In G.I. Pipe Including Supplying And Fitting Jam Nuts And Extra Socket Etc. , Rising And Distribution Network With House Connection Up To 10 Nos. Including Platform & Stand Post , Earth Work In Excavation In Foundation Trenches In Hard Soil (Vide Classification Soil Item B) And Disposal Of Excavated Earth As Obtained To A Distance Up To 50 Mtr. Including All Lifts, Leveling, Ramming The Foundation Trenches, Removing Roots Of Trees, Shrubs All Complete As Per Approved Design, Specification And Direction Of E/I. , Dismantling Plain Cement Concrete Work Including Stacking Serviceable Materials In Countable Stacks Within 15 M Lead And Disposal Of Unserviceable Materials With All Leads All Complete. , Providing Pccm-200 With Nominal Mix Of (1:1.5:3) With Approved Quality Of Stone Chips 20 Mm To 6 Mm Size Graded And Clean Coarse Sand Of Fm 2.5 To 3.0 Including Screening, Shuttering, Mixing Cement Concrete In Mixer And Placing In Position, Vibrating, Sticking, Curing , Taxes And Royalty All Complete As Per Specification And Direction Of E/I. For Construction Of Road Cutting Portion. , Rising Main , Manufacture, Supply And Delivery Offollowing Nominal Dia Upvc Column Pipes Including Pvc Socket (Coupler), , 65Mm Dia -Density Of Pipe 1.38 To 1.43 Gm Per Cm3 Od:74.5 To 75.2Mm Wall Thickness End:9Mm To 10.7Mm, Barrel 9Mm To 10.7 Mm, Length: 3Mtrs.Rising Main , 50 Mm Dia -Density Of Pipe 1.38 To 1.43 Gm Per Cm3 Od:87.5 To 88.2Mm Wall Thickness End:9 .8 Mm To 11.9Mm, Barrel 7.3Mm To 9 Mm, Length: 3Mtrs. Delivery Pipe , Distribution Main , Providing And Supplying High Density Polyethylene Pipe (Hdpe Pipe) Of 20 Mm To 225 Mm Od And Pressure 6.0 Kg/Cm2 And 10 Kg/Cm2 Suitable For Water Supply Which Is Available In All Standard Conforming To Isi -- 4984/14151/12786/13488,Iso 4427 , Din-8074Materials Rates Are Ex-Factory Excluding Transportation, Taxes And Duties. Pe-80 , Pn- 10. , 63 Mm Hdpe Pipe , 50 Mm Hdpe Pipe , 32 Mm Hdpe Pipe- , 20 Mm Hdpe Pipe- , Providing And Fixing Gun Metal Gate Valvewith C I Wheel Of Approved Quality(Screwed End). , 65 Mm Dia , 50 Mm Dia . , Providing And Supplying High Density Polyethylene(Hdpe )Fittings Of 20 Mm To 225 Mm Od And Pressure 6.0 Kg/Cm2 And 10 Kg/Cm2 Suitable For Water Supply Which Is Available In All Standard Conforming To Isi -- 4984/14151/12786/13488,Iso 4427 , Din-8074Materials Rates Are Ex-Factory Excluding Transportation, Taxes And Duties. , Lowering, Laying And Jointing H. D. P. E./M. D.P. E. Pipes In Proper Position Including All Specials By Compression Fitting/Electro Fusion And Butt Fusion Jointing Procedure As Per Relevant Is Code Complete With All Materials For Jointing Procedure Like Electro Fusion Machine, Electric Heater/Butt Fusion Welding Machine With Hydraulic Jack, Top Loading Clamp Etc. And All Labours As Directed By Engineer In Charge As Per Is-7634 Part Ii. , For Rising , 65 Mm Hdpe Pipe , 50 Mm Hdpe Pipe , For Distribution , 65 Mm Hdpe Pipe , 50 Mm Hdpe Pipe , 32 Mm Hdpe Pipe , 20 Mm Hdpe Pipe , 15 Mm Dia Gi Pipe , Supplying All Materials , Labour And Tools For Fixing 15 Mm Dia G.I. Pipes With Red Lead And Yarn Of Following Nominal Bore With Screwed And Socketed Joints On Wall, Ceiling And Floor Including Supplying And Fitting Of Wall Hooks Or Pipe Clamps, Wooden Plugs, Cutting Pipes To Size And Threading Ends If Required Etc. All Complete As Per Specification And Direction Of Engineer-In-Charge. , Supplying And Fixing G.I. Fittings Of Approved Make All Complete As Per Specification And Direction Of E/I. , Elbow 15 Mm Dia. , Reducer Socket 20X15 Mm Dia. , Nipple 15 Mm Dia. , Plain Socket 15 Mm Dia. , Supplying And Fixing G.M. Ferrule Of Approved Make In Existing C.I./D.I. Main Including Drilling And Taping C.I./D.I. Main All Complete As Per Specification And Direction Of E/I. 3 Mm, 6 Mm 10 Mm Dm Ferrule Weight Not Less Than 425 Gram. , Providing And Fixing Gun Metal Full Way Valve Of Approved Quality, All Complete, As Per Specification And Direction Of E/I. , 65 Mm Dia Full Way Valve , 50 Mm Dia And Weight Not Less Than 1.5 Kg. , Providing And Fixing Of Male Ended C.I.Body Brass Spindle Valve And Seat Bib Cock Of Approved Quality With Extra Socketall Complete As Per Specification And Direction Of E/I. , 15 Dia And Weight Not Less Than 400 Gm , Constructing Masonry Chamber 30X30x50 Cm Inside, In Brick Work In Cement Mortar 1:4 (1 Cement :4 Coarse Sand) For Stop Cock, With C. I. Surface Box 100X100 X75 Mm (Inside) With Hinged Cover Fixed In Cement Concrete Slab 1:2:4 Mix (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size), I/C Necessary Excavation, Foundation Concrete 1:5:10 ( 1 Cement : 5 Fine Sand : 10 Graded Stone Aggregate 40Mm Nominal Size ) And Inside Plastering With Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) 12Mm Thick, Finished With A Floating Coat Of Neat Cement Complete As Per Standard Design.With Common Burnt Clay F.P.S.(Non Modular) Bricks Of Class Designation 7.5. , Full Way Valve Chamber , Supplying Materials , Labours And Equipments For Construction Of 0.90M X 0.90 M Size P.C.C. (1:2:4) Rectangular Platform With Stand Post In House Including 12 Mm Thick Cement Plaster In C.M. (1:4) With Neat Cement Punning Over Exposed Surfaceall Complete Job, As Per Approved Design, Specification And Direction Of E/I. , Providing Brick Masonry Chamber Ofinner Size 600 X 600 X 450 Mm Deep For Bore Well Protection Having 125 Mm Thick Wall And 75 Mm R.C.C Cover Including Cement Plaster Of Exposed Surface, Etc All Complete Job. , Earth Work In Back Filling The Trenches After Laying Different Types And Size Of Pipes With Earth Removed During Excavation Within Initial Lead And Lift As Per Specification And Direction Of Engineer-In-Charge. , Providing Fitting & Fixing 32 Mm To 50 Mm Service Hdpe Saddleall Complete Job, As Per Approved Design, Specification And Direction Of E/I. , Carriage Of Materials From Different Sources Or Departmental Stores To Work Site Including Loading, Transporting, Unloading And Stacking The Materials At Work Site Etc. All Complete Job. As Per Direction Of E/I. , Cement Lead 10 Km (Avg.) , Sand Lead 36 Km (Avg.) , Stone Chips Lead 11 Km (Avg.) , Steel Reinforcement Lead 10 Km (Avg.) , Bricks Lead 06 Km (Avg.) , Annual Operation & Maintenance Cost Based On Existing D/T Well With Solarmotor Pump For 5 Years , O & M Cost For 1St Year , O & M Cost For 2Nd Year , O & M Cost For 3Rd Year , O & M Cost For 4Th Year , O & M Cost For 5Th Year , Provision Of One No Sim Card & Its Recharging Cost For Rmc , Model-1B With Source (Drilled T/W 125/115Dia Mm, 60M Deep) , Tube Well , Drilling Portion , Construction For 115/125 Mm Dia Drilled Tube-Well For Drilling In All Kinds Of Soil Rock For Installation Of Hand Pump With D.T.H Rig Machine All Complete Including Supplying All Materials, Labours, Tools, Drilling, Rigs, Air Compressor And Equipments As Well As Fuel Lubricant For Making 125/115 Mm Dia Boring Etcand Cost Of Transporting Rig Machine And Other Vehicle Up To Site Workas Per Specification And Direction Of Engineer-In-Charge. , (A) Up To 30Mtr. Depth Bellow G.L. In Rural Areas , (B) Beyond 30Mtr.In Rural Areas , Providing All Equipments And Labour For Lowering 125Mm Dia Blue Upvc Casing Pipe As Casing For Protecting The Side From Falling During The Process Of Drilling All Complete Job Including Carriage Of Material To Work Site. , Supplying Labour Cement And Calcium Chloride Or Bentonite Solution And Equipments For Grouting To Casing Pipe All Complete Job Including Carriage Of Material To Work Site As Per Specification & Direction Of E/I , Supplying All Tools, Equipments And Labour And Doing Washing, Flushing And Development Of Drilled Tube Well To Give Clean And Clear Water All Complete As Per Direction E/I. , Supplying All Materials Labours And Equipment Including 125 Mm Dia Gi/Ci Cap 125 Mm Dia T/W Properly All Complete And Taking It Out As Per Specification & Direction Of E/I. (The Cap Will Be Property Of Department) , Civil Portion , Supplying All Tools, Equipment, Labours And Lowering 32 Mm Dia G.I. (Medium)Pipe In Dt In 3 Mtr. Length All Complete Job As Per Direction Of E/I. Including Carriage Of Materials. , Supplying All Tools, Labour For Fitting And Fixing Deep Well Cylinder With Necessary Connecting Rod All Complete Job As Per Specification & Direction Of E/I. , Supplying All Materials, Labours For Fitting And Fixing Of India Mark Ii Hand Pump With All Accessories All Job Complete As Per Direction Of E/I. Including Carriage Of Materials. , Supplying All Materials, Labours And Equipment For Constructing Pcc (1:2:4) Circular Platform Around Each Drilled Tube Well Including 12Mm Thick Cement Plaster (1:4) With Neat Cement Punning Over Exposed Surface As Per Unicef Design Etc. All Complete. Including Carriage Of Materials. , Supplying All Materials Labour And Equipment For Constructing Pcc (1:2:4) Drain As Per Unicef Design Etc. All Complete .Including Carriage Of Materials. , Add Extra Item For Supplying Tools, Labours And Materials For Painting, Numbering And Year For Construction Of T/Well And Taking Of Colour Photograph With Two Or Three Nearest Persons Including Platform, Drain, Soak Pit And Also Longitude & Latitude, Details Of T/W Such As Total Depth, Casing Depth, Static Water Level, Drawdown, Discharge, Strata Chart, Beneficiary Population Etc In Separate Sheet/Format All Complete As Per Direction Of E/I. , Cost Of Materials , Cost Of Standard I.S.I. Mark Deep Well Hand Pump For India Mark-Ii, I.S.I. 15500 (Part 2) / 2004 With Latest Revision Including 12Mm X 3 Meter Long 8 No. Connecting Rods Made Of Bright Bar Electro-Galvanized Fitted With Coupler & Normal Stand Assembly Recommended For Use With Cylinder Assembly Suitable For Bore Wellcasing Pipe. , Cost Of 32 Mm Dia Gi Pipe (Medium) 3 Mtrs Long Screwed At Both Ends With Seamless Socket As Per Is:1239(Part 1990). , Cost Of 125 Mm Dia Blue Upvc Casing Pipe As Per I.S.12818/2016 Cml No.- 5543459 , Rcc Foundation For Steel Structurestaging& Solar Panel , Earth Work In Excavation In Foundation Trenches In Ordinary Soil And Disposal Of Excavated Earth As Obtained To A Distance Up To 50.0M ,Including All Lifts, Levelling ,Ramming The Foundation Trenches, Removing Roots Of Trees, Shrubs All Complete As Per Approved Design ,Building Specification And Direction Of E/I(Vide Classification Of Soil Item -B) , Providing Coarse Clean Sand In Filling In Foundation Trenches Or In Plinth Including Ramming And Watering In Layers Not Exceeding 150Mm Thick With All Leads And Lifts Including Cost Of All Materials ,Labour ,Royalty And Taxes All Complete As Per Building Specification And Direction Of E/I , Back Filling , Providing Nominal Mix Pcc Of (1:2:4) In Foundationwith Approved Quality Of Stone Chips 20Mm To 6Mm Size Graded And Clean Coarse Sand Of F.M.2.5To 3 Including Screening Shuttering Mixing Cement Concrete In Mixer And Placing In Position Vibrating Striking Curing And Royalty All Complete As Per Building Specification And Direction Of E/I , Providing Rcc M-20 In Nominal Mix Of (1:1.5:3) In Columnswith Approved Quality Of Stone Chips 20Mm To 6Mm Size Graded And Clean Coarse Sand Of F.M.2.5To 3 Including Screening Shuttering Mixing Cement Concrete In Mixer And Placing In Position Vibrating Striking Curing And Royalty All Complete As Per Building Specification And Direction Of E/I. , (A)Foundation For Steel Structure Staging , Footing And Vertical Pedestal Raft , Column , Tie Beam , (B)Foundation For Solar Panel , Footing , Vertical Pedestal , Providing For Steel Reinforcement As Per Approved Design And Drawing Excluding Carriage Of T.S. Bar To Work Site Cutting, Bending With Annealed Wire With Cost Of Wire, Removal Of Rust Placing The Rods In Position All Complete As Per Building Specification And Direction Of E/I. , (A) Foundation For Steel Structure Staging , Carriage Of Materials From Different Sources Or Departmental Stores To Work Site Including Loading, Transporting, Unloading And Stacking The Materials At Work Site Etc. All Complete Job. As Per Direction Of E/I. , Cement Lead 10 Km (Avg.) , Sand Lead 36 Km (Avg.) , Stone Chips Lead 11 Km (Avg.) , Steel Reinforcement Lead 10 Km (Avg.) , Bricks Lead 06 Km (Avg.) , Galvanized Tubular Steel Structure Staging Forhdpe Water Storage Tank& Solar Panel , Providing Structural Steel Galvanisedsqure Pipe Section Work In Trusses, Other Similar Trussed Purlins And Members With All Bracing ,Gusset Plates Etc As Per Detailed Design And Drawing Or As Directed By Engineer- In-Charge ,Including Cutting Fabricating ,Hoisting , Erecting And Fixing In Position , Making Riveted/Bolted /Welded Connections And One Coat Of Anticorrosive Paint And Over It Two Coat Of All Oil Painting & For Structure(Plus) Providing And Applying Materials &Labour For Hot Dip Galvanizing Of Above Structure Including Transportation For Galvanizing Minimum Thickness 80Microns (Net Wt. Of Components To Be Galv) Preferably Tata Structural Section Etc Complete. , Hardware (L.S.) , Information Board For Iec , Providing Structural Steel Work In Trusses Other Similar Trussed Purlins And Members With Bracing Gusset Plates Etc As Per Detailed Design And Drawing Or As Directed By Engineer- In-Charge Including Cutting Fabricating Hoisting Erecting And Fixing In Position Making Reverted Bolted Welded Connections One Coat Of Anticorrosive Paint And Over It Two Coats Of Oil Painting Etc Complete , Installation Of 5000 Liters Capacity Water Storage Tank , Providing And Fixing Hdpe Container Syntex Or Alike One Piecemolded Water Tank Made Out Of Low Density Polythyler Andbuilt Corrugation Including Of Delivery Up To Destination Hoisting And Fixing Of Accessories Such As Inlet, Outlet Overflow Of All Tanks Capacity 5000.00 Litres Capacity Water Storage Tank , Transportation Charge , Lifting Of 5000 Litrs Capacity Tank Up To 4.00M Height With Lifting Tools With Rope And Labour , Making Hole In Tank , Making Long Screw In G.I. Pipe Including Supplying And Fitting Jam Nuts And Extra Socket Etc. , Rising And Distribution Network With House Connection Up To 20 Nos. Including Platform & Stand Post , Earth Work In Excavation In Foundation Trenches In Hard Soil (Vide Classification Soil Item B) And Disposal Of Excavated Earth As Obtained To A Distance Up To 50 Mtr. Including All Lifts, Leveling, Ramming The Foundation Trenches, Removing Roots Of Trees, Shrubs All Complete As Per Approved Design, Specification And Direction Of E/I. , Dismantling Plain Cement Concrete Work Including Stacking Serviceable Materials In Countable Stacks Within 15 M Lead And Disposal Of Unserviceable Materials With All Leads All Complete , Providing Pccm-200 With Nominal Mix Of (1:1.5:3) With Approved Quality Of Stone Chips 20 Mm To 6 Mm Size Graded And Clean Coarse Sand Of Fm 2.5 To 3.0 Including Screening, Shuttering, Mixing Cement Concrete In Mixer And Placing In Position, Vibrating, Sticking, Curing , Taxes And Royalty All Complete As Per Specification And Direction Of E/I. For Construction Of Road Cutting Portion , Rising Main , Manufacture, Supply And Delivery Offollowing Nominal Dia Upvc Column Pipes Including Pvc Socket (Coupler), , 65Mm Dia -Density Of Pipe 1.38 To 1.43 Gm Per Cm3 Od:74.5 To 75.2Mm Wall Thickness End:9Mm To 10.7Mm, Barrel 9Mm To 10.7 Mm, Length: 3Mtrs.Rising Main , 50 Mm Dia -Density Of Pipe 1.38 To 1.43 Gm Per Cm3 Od:87.5 To 88.2Mm Wall Thickness End:9 .8 Mm To 11.9Mm, Barrel 7.3Mm To 9 Mm, Length: 3Mtrs. Delivery Pipe , Distribution , Providing And Supplying High Density Polyethylene Pipe (Hdpe Pipe) Of 20 Mm To 225 Mm Od And Pressure 6.0 Kg/Cm2 And 10 Kg/Cm2 Suitable For Water Supply Which Is Available In All Standard Conforming To Isi -- 4984/14151/12786/13488,Iso 4427 , Din-8074Materials Rates Are Ex-Factory Excluding Transportation, Taxes And Duties. , 63 Mm Hdpe Pipe , 50 Mm Hdpe Pipe , 32 Mm Hdpe Pipe , 20 Mm Hdpe Pipe , Providing And Fixing Gun Metal Gate Valvewith C I Wheel Of Approved Quality(Screwed End). , 65 Mm Dia , 50Mm Dia , Providing And Supplying High Density Polyethylene(Hdpe )Fittings Of 20 Mm To 225 Mm Od And Pressure 6.0 Kg/Cm2 And 10 Kg/Cm2 Suitable For Water Supply Which Is Available In All Standard Conforming To Isi -- 4984/14151/12786/13488,Iso 4427 , Din-8074Materials Rates Are Ex-Factory Excluding Transportation, Taxes And Duties. , Lowering, Laying And Jointing H. D. P. E./M. D.P. E. Pipes In Proper Position Including All Specials By Compression Fitting/Electro Fusion And Butt Fusion Jointing Procedure As Per Relevant Is Code Complete With All Materials For Jointing Procedure Like Electro Fusion Machine, Electric Heater/Butt Fusion Welding Machine With Hydraulic Jack, Top Loading Clamp Etc. And All Labours As Directed By Engineer In Charge As Per Is-7634 Part Ii. , For Rising , 50 Mm Hdpe Pipe , 65 Mm Hdpe Pipe , Distribution , 65 Mm Hdpe Pipe , 50 Mm Hdpe Pipe , 32 Mm Hdpe Pipe , 20 Mm Hdpe Pipe , Providing 15 Mm Dia. G.I. Pipe Tata Or Equivalent Make As Per Is 1239 (Part 1/2004) Isi Mark /Medium Quality In Stand Post. , Supplying All Materials , Labour And Tools For Fixing 15 Mm Dia G.I. Pipes With Red Lead And Yarn Of Following Nominal Bore With Screwed And Socketed Joints On Wall, Ceiling And Floor Including Supplying And Fitting Of Wall Hooks Or Pipe Clamps, Wooden Plugs, Cutting Pipes To Size And Threading Ends If Required Etc. All Complete As Per Specification And Direction Of Engineer-In-Charge. , Supplying And Fixing G.I. Fittings Of Approved Make All Complete As Per Specification And Direction Of E/I. , Elbow 15 Mm Dia. , Reducer Socket 20X15 Mm Dia. , Nipple 15 Mm Dia. , Plain Socket 15 Mm Dia. , Supplying And Fixing G.M. Ferrule Of Approved Make In Existing C.I./D.I. Main Including Drilling And Taping C.I./D.I. Main All Complete As Per Specification And Direction Of E/I. 3 Mm, 6 Mm 10 Mm Dm Ferrule Weight Not Less Than 425 Gram. , Providing And Fixing Gun Metal Full Way Valve Of Approved Quality, All Complete, As Per Specification And Direction Of E/I. , 65 Mm Dia Full Way Valve , 50 Mm Dia And Weight Not Less Than 1.5 Kg. , Providing And Fixing Of Male Ended C.I.Body Brass Spindle Valve And Seat Bib Cock Of Approved Quality With Extra Socketall Complete As Per Specification And Direction Of E/I. , 15 Dia And Weight Not Less Than 400 Gm , Constructing Masonry Chamber 30X30x50 Cm Inside, In Brick Work In Cement Mortar 1:4 (1 Cement :4 Coarse Sand) For Stop Cock, With C. I. Surface Box 100X100 X75 Mm (Inside) With Hinged Cover Fixed In Cement Concrete Slab 1:2:4 Mix (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size), I/C Necessary Excavation, Foundation Concrete 1:5:10 ( 1 Cement : 5 Fine Sand : 10 Graded Stone Aggregate 40Mm Nominal Size ) And Inside Plastering With Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) 12Mm Thick, Finished With A Floating Coat Of Neat Cement Complete As Per Standard Design.With Common Burnt Clay F.P.S.(Non Modular) Bricks Of Class Designation 7.5. Full Way Valve Chamber , Supplying Materials , Labours And Equipments For Construction Of 0.90M X 0.90 M Size P.C.C. (1:2:4) Rectangular Platform With Stand Post In House Including 12 Mm Thick Cement Plaster In C.M. (1:4) With Neat Cement Punning Over Exposed Surfaceall Complete Job, As Per Approved Design, Specification And Direction Of E/I. , Providing Brick Masonry Chamber Ofinner Size 600 X 600 X 450 Mm Deep For Bore Well Protection Having 125 Mm Thick Wall And 75 Mm R.C.C Cover Including Cement Plaster Of Exposed Surface, Etc All Complete Job , Earth Work In Back Filling The Trenches After Laying Different Types And Size Of Pipes With Earth Removed During Excavation Within Initial Lead And Lift As Per Specification And Direction Of Engineer-In-Charge. , Providing Fitting & Fixing 32 Mm To 50 Mm Service Hdpe Saddleall Complete Job, As Per Approved Design, Specification And Direction Of E/I. , Carriage Of Materials From Different Sources Or Departmental Stores To Work Site Including Loading, Transporting, Unloading And Stacking The Materials At Work Site Etc. All Complete Job. As Per Direction Of E/I. , Cement Lead 10 Km (Avg.) , Sand Lead 36 Km (Avg.) , Stone Chips Lead 11 Km (Avg.) , Steel Reinforcement Lead 10 Km (Avg.) , Bricks Lead 06 Km (Avg.) , Solar Photovoltaic (Spv) Solar Submersible D.C. Water Motor Pump , Designing, Supplying, Installation, Testing & Commissioning With All Tools & Parts Of Following Solar Photovoltaic (Spv) Solar Submersible D.C. Water Motor Pump Suitable For Minimum 125Mm X 115Mm Bore Well As Per Mnre Guideline With Following Specifications & Accessories. , Spv Arrays Contains Specified No Of Same Capacity Type & Specification Modules Connected To Series Or Parallel To Obtained The Required Voltage & Current The Power Output Of Individual Pvmodules Should Be Minimum 200 Watt Peak. , I) The Spv Modules Should Be As Per Iec-61215 And Iec 61730 Part 1.0) , Ii) All External Parts Of Motor Pump Used In Submersible Pump Which Are In Contact Of Water Is Stainless Steel Grade 303 Or Higher As Required. , Iii) The Pv Modules Shouldbe Mounted On Metallic Structure Of Adequate Strength And Appropriate Design Which Can Withstand Load Of Modules & High Wind Pressure Up To 200Km/H. , Iv) The Module Mounting Structure Should Be Hot Dip Galvanized According To Is 4759. , V) To Enhance The Performance Of Spv Water Pumping System & Arrangement For Seasonal Tilt Angle Adjustment Should Be Provided , Vi) Necessary Arrangement Should Be Provided In Controller Automatic Start-Run-Stop Through Out The Day With Water Level Detection System. (As Per Mnre Specification) , Vii) Necessary Protection Such As Lightening Arrestor Etc. Should Be Provided To Protect The Controller & Spv , Viii) The Suction/Delivery Pipe Shall Be Upvc / H.D.P.E. Pipes Of Appropriate Size 60M Or More As Required Minimum Pressure Rating Of 8Kg/Sq Cm- Pe 100 Grade For Pump Up To 3Hp & 10 Kg/Sq Cm- Pe 100 Grade For 5 Hp. , Ix) All Cable Used Shall Be As Per Is 694. Suitable Size Of Cable Shall Be Used In Sufficient Length For Inter Connection Between The Spv Array To Spv Controller And Spv Controller To Solar Power Pump. Provision Of Cable Shall Be As Per Is 14536. , X) The Motor Pump Set Should Have A 5 Years Warranty. , Xi) Control Panel Suitable For Motor Pump With Arrangement Of Dry Run & Over Flow Protection Sensor, Float Switch & Rain Prevention Box. (As Per Mnre Specification) , Xii) The Spv Controller Must Have Ip-65 Protection Or Must Be Housed In Cabinet Having At Least Ip-65 Protection. , Xiii) The System Should Be As Per Mnre Guide Line & Eco-Friendly With Suitable Arrangement To Operate New Pump Manually. , Xiv) With Third Party Inspection Before Dispatch. , Xv) Provision For Web Basedremote Monitoring Of The Pumps To Be Installed Must Be Made Through The Inbuilt Controllers . It Should Be Possible To Ascertain The Daily Water Output, The Power Generated By Pv Array ,The Up And Downtime Of The Pump During The Year, Number Of Days The Pump Was Unused Or Under Breakdown Repairs. , The Following Details Should Be Marked Indelibly On The Motor Pump Set , A) Name Of The Manufacturer Or Distinctive Logo. , B) Model Number. , C) Serial Number. , Solar Submersible Motor Pump (Spv Dc Type) , I) 1 Hp (Dc Pump) With 900 Wp Minimum Watt P.V. Panel As Mnre Pump Head Max Shut-Off Head Up To 120 Mtrs. For Higher Or Lower Head Or In Between Various Modules Output Could Be Decided On Prorates Basis. (As Per Latest Guide Line Of Mnre) , Carrying Out Recuperation/Yield Test For Ascertaining The Discharge Of Constructed Well/ Excavated Profile As Directed By The Iec. The Testout By The Drawing Down Water From The Well/ Profile Below Normal/Subsoil Water Level Up To Full Depth Rise Is Recorded The Normal Water Level/Subsoil Water Level In The Well / Profile As Well As Strainer/Level At Pump As Per Design Of W.S. Scheme Shall Be Recorded Prior To The Test Including Cost Of All Materials, Over Load , Labours Etc. Complete As Directed. , Supplying All Labours, Tools And Equipments For Dismantling Of Head & Water Tank Assembly And Taking Out 32 Mm Dia Old G.I. Pipe, Connecting Rod, Cylinder Assembly The Dismantled Components After Necessary Changing For Making The T/W In Good Condition With All Transportation Including Unused Taken Out Materials Back In Store All Complete Job As Per Direction Of E/I. (As Per Model Estimate Of Solar Energy Based Mini Wss. Ts Done By Se, Ranchi Circle & Circle Gumla Dt. 21.05.2019) , Provision Of Solar Night Lamp. , Galvanised Chain-Line Mess Fencing Around Solar Panel Where Bore Well Is Away From Tower , Making 30 Cm (12) Dia Bore Up To 4M Below Ground With Hand Auger Of Approved Quality In Ordinary Soil (Vide Classification Of Soil Item-A) True To Plum And Without Eccentricity In Any Stage Of Operation And Disposal Of The Exacavated Earth Up To 50M Lead Including All Lifts All Complete As Per Approved Design And Direction Of E/I. , Providing Pcc M-150 In Nominal Mix Of (1:2:4) In Foundationwith Approved Quality Of Stone Chips 20Mm To 6Mm Size Graded And Clean Coarse Sand Of F.M.2.5 To 3 Including Screening Shuttering, Mixing Cement Concrete In Mixer And Placing In Position, Vibrating, Curing, Taxes And Royalty All Complete As Per Building Specification Direction Of E/I. , Labour Cost Of Fitting And Fixing Galvanised Chain-Link Mess Up Height Of 2 M Including Cost Of Staples (But Excluding The Cost Of Cement Concete Angle Iron Posts, Its Cutting And Making Holes, Nuts And Bolts) All Complete As Per Specification And Direction Of E/I. , Drilling 6Mm Dia Holes In M.S Angle Iron For Fixing Of Stables Etc. As Per Building Specification And Direction Of E/I. , Labour Cost Cutting Of M.S Angle Iron Posts To Required Length, One End Splitted As Fish Tailed In A Length Of 150Mm Complete As Per Building Sepcification And Direction Of E/I. , Supplying, Fitting And Fixing Straining Bolts With Nut Size 22Cm*10Mm Dia Tighten The Barbed Wire With Corner Post Complete As Per Building Specification And Direction Of E/I. , Supplying, Fitting And Fixing Galvanised Chain -Link Mess Having 3Mm Thick Wire Cell Type 40 X 40 Mm Fitted On M.S. Angle Frame With Two Diagonals Having 25X25x5mm Size Angle Including Cost Of Fabrication, Providing Necessary Bocking Arrangement With Haskal And Domny Duly Fixed In Angle Post, Applying A Priming Red Lead Paint Over Steel Work, Taxes Excluding The Cost Of Galvanised Chain-Link Mess All Complete. , Cost Of Galvanised Chain-Link Mess Having 3 Mm Thick Wire Cell Type 40X40 Mm Not Less Than 3.1 Kg/Sqm , Cost Of 50 X 50 X 6 Mm M.S Angle , Carriage Of Materials From Different Sources Or Departmental Stores To Work Site Including Loading, Transporting, Unloading And Stacking The Materials At Work Site Etc. All Complete Job. As Per Direction Of E/I. , Cement Lead 10 Km (Avg.) , Sand Lead 36 Km (Avg.) , Stone Chips Lead 11 Km (Avg.) , Steel Reinforcement Lead 10 Km (Avg.) , Annual Operation & Maintenance Cost Based On Existing D/T Well With Solarmotor Pump For 5 Years , O & M Cost For 1St Year (Excluding Repair Charges) , O & M Cost For 2Nd Year With Annual Repair Charges , O & M Cost For 3Rd Year , O & M Cost For 4Th Year , O & M Cost For 5Th Year , Provision Of One No Sim Card & Its Recharging Cost For Rmc , Model- 02 (8000 Litre 8 Meter Staging) , Construction Of 125 Mm X 115 Mm X 90.0 M Deep Drilled Tube Well , Supplying All Materials, Labour And Tools And Equipment For Drilling 125 X 115 Mm Dia Bore Well In Any Kinds Of Soil And Rocks By Using D.T.H. Super Rig Machine And Ball Hammer Technology Including All Technology Inclusive Of Mobilization, Demobilization Of Rigs Air Compressor All Accessories Of Rigs Tools And Plant Labour Etc. All Complete Job Including Transportation Charge Cost Of Flushing Charge, Geographical Investigation Etc. All Complete , (A) 0.00M Up To 30.00M Depth Below G.L. In Rural Areas , (B) 30.000M Up To 120.00M Depth Beyond . In Rural Areas , Basic Rate Of 125Mmdia Blue Upvc Casingpipe Confirming To I.S.I . Latest Revision Is(12818)/2016 , Supplying All Materials, Labour And Inserting Upvc Bluepipe 125 Mm Internal Dia Casing Pipe For Protecting The Bore Hole In Over Burden Up To Hard Surface As Per Is 12818-1392 With Latest Revision All Complete Job With Taxesas Per Specification And Direction Of E/I. , Supplying Labour Cement And Calcium Chloride Or Bentonite Solution And Equipment’S For Grouting Casing Pipe , Supplying All Tools, Equipments And Labour And Doing Washing, Flushing And Development Of Drilled Tube Well To Give Clean And Clear Water All Complete As Per Direction E/I. , Supplying Laboursand Equipment’S Including 125 Mm Dia G.I. Cap & Fittingand Fixing Over Thecasing Pipe Of Bore Well Properly And Taking It Out As Per Direction Of E/I. , Supplyingmaterials And Labours For Constructing Bore Well Chamber Of 75 B Designation Brick Masonry Chamber 600 Mm X 450 Mm And 750 Mm Deep Internal Dimension Having 250Mm Thickness In Cement Mortar 1:6 Including 12Mm Cement Plaster 1:6 With 600 Mm X 475 Mm Rcc Cover With Earth Work In Excavation And 75 Mm Thick Pcc (1:3:6) In Foundation And Refilling All Complete As Per Specification And Direction Of E/I. , 2 H.P. D.C. Solarmotor Pump Complete Set , Designing, Supplying, Installation, Testing & Commissioning With All Tools & Parts Of Following Solar Photovoltaic (Spv) Solar Submersible D.C. Water Motor Pump Suitable For Minimum 125Mm X 115Mm Bore Well As Per Mnre Guideline With Following Specifications & Accessories. , Spv Arrays Contains Specified No Of Same Capacity Type & Specification Modules Connected To Series Or Parallel To Obtained The Required Voltage & Current The Power Output Of Individual Pvmodules Should Be Minimum 200 Watt Peak. , I) The Spv Modules Should Be As Per Iec-61215 And Iec 61730 Part 1.0) , Ii) All External Parts Of Motor Pump Used In Submersible Pump Which Are In Contact Of Water Is Stainless Steel Grade 303 Or Higher As Required. , Iii) The Pv Modules Shouldbe Mounted On Metallic Structure Of Adequate Strength And Appropriate Design Which Can Withstand Load Of Modules & High Wind Pressure Up To 200Km/H. , Iv) The Module Mounting Structure Should Be Hot Dip Galvanized According To Is 4759. , V) To Enhance The Performance Of Spv Water Pumping System & Arrangement For Seasonal Tilt Angle Adjustment Should Be Provided , Vi) Necessary Arrangement Should Be Provided In Controller Automatic Start-Run-Stop Through Out The Day With Water Level Detection System. (As Per Mnre Specification) , Vii) Necessary Protection Such As Lightening Arrestor Etc. Should Be Provided To Protect The Controller & Spv , Viii) The Suction/Delivery Pipe Shall Be Upvc / H.D.P.E. Pipes Of Appropriate Size 60M Or More As Required Minimum Pressure Rating Of 8Kg/Sq Cm- Pe 100 Grade For Pump Up To 3Hp & 10 Kg/Sq Cm- Pe 100 Grade For 5 Hp. , Ix) All Cable Used Shall Be As Per Is 694. Suitable Size Of Cable Shall Be Used In Sufficient Length For Inter Connection Between The Spv Array To Spv Controller And Spv Controller To Solar Power Pump. Provision Of Cable Shall Be As Per Is 14536. , X) The Motor Pump Set Should Have A 5 Years Warranty. , Xi) Control Panel Suitable For Motor Pump With Arrangement Of Dry Run & Over Flow Protection Sensor, Float Switch & Rain Prevention Box. (As Per Mnre Specification) , Xii) The Spv Controller Must Have Ip-65 Protection Or Must Be Housed In Cabinet Having At Least Ip-65 Protection. , Xiii) The System Should Be As Per Mnre Guide Line & Ecofriendly With Suitable Arrangement To Operate New Pump Manually. , Xiv) With Third Party Inspection Before Dispatch. , Xv) Provision For Web Basedremote Monitoring Of The Pumps To Be Installed Must Be Made Through The Inbuilt Controllers . It Should Be Possible To Ascertain The Daily Water Output, The Power Generated By Pv Array ,The Up And Downtime Of The Pump During The Year, Number Of Days The Pump Was Unused Or Under Breakdown Repairs. , The Following Details Should Be Marked Indelibly On The Motor Pump Set , A) Name Of The Manufacturer Or Distinctive Logo. , B) Model Number. , C) Serial Number. , Solar Submersible Motor Pump (Spv Dc Type) , I) 2 Hp (Dc Pump) With 1800 Wp Minimum Watt P.V. Panel As Mnre Pump Head Max Shut-Off Head Up To 100 Mtrs. For Higher Or Lower Head Or In Between Various Modules Output Could Be Decided On Prorates Basis. (As Per Latest Guide Line Of Mnre) , Provision Of Solar Night Lamp. , 8000 Litre Capacityr.C.C. Water Tank (2.1 X 2.1 X 2.1 M Internal Size) With 8 M Staging Having Utility Room At Ground Level , Earth Work In Excavation In Foundation Trenches In Ordinary Soil (Vide Classification Of Soil Item-B ) And Disposal Of Excavated Earth As Obtained To A Distance Up To 50 M Including All Lifts,Levelling,Ramming The Foundation Trenches, Removing Roots Of Trees Shrubs All Complete As Per Approved Design, Building Specification And Direction Of E/I. , Providing P.C.C.M-150 In Nominal Mix Of (1:2:4) In Foundation With Approved Quality Of Stone Chips 20Mm To 6Mm Size Graded And Clean Coarse Sand Of F.M 2.5 To 3 Including Screening, Mixing Cement Concrete In Mixer And Placing In Position,Vibrating,Curing,Taxes And Royalty All Complete As Per Building Specification Direction Of E/I. , Providing And Laying In Situ Cement Concrete Of Trap/Granite/Quartzite/ Gneiss Metal For Rcc Work In Foundation Like Raft, Grillage, Strip Foundation And Footing Of Rcc Columns And Steel Stanchions Including Normal Dewatering, Plywood Form Work, Bully/Steel Propups, Compaction, Finishing Andcuring, Etc, Complete. (By Weigh Batching And Mix Design For M-250Only. Use Of L & T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, Etc. Cement Is Permitted.) , Providing And Casting In Situ Cement Concrete Of Trap/Granite/Quartzite/ Gneiss Metal Of Approved Quality For Rcc Work As Per Detailed Drawings And Designs Or As Directed By Engineer-In-Charge Including Normal Dewatering, Centering, Plywood Formwork, Bully/Steel Prop-Ups, Compaction, Finishing The Formed Surfaces With Cm 1:3 Of Sufficient Minimum Thickness If Special Finish Is To Be Provided And Curing, Etc. Complete. (By Weigh Batching And Mix Design For M-250 And M-300 Only.Use Of L&T, A.C. C., Ambuja, Birla Gold, Manikgad, Rajashree, Etc. Cement Is Permitted) , G.L To Above Roof Of Utility Room , Column Utility Room, Roof Beam To Tank Beam M-25 , Column Tank Beam To Tank Roof M-25 , Providing And Casting In Situ Cement Concrete Of Trap/Granite/Quartzite/ Gneiss Metal Of Approved Quality For Rcc Work As Per Detailed Drawings And Designs Or As Directed By Engineer-In-Charge Including Normal Dewatering, Centering, Plywood Formwork, Bully/Steel Prop-Ups, Compaction, Finishing The Formed Surfaces With Cm 1:3 Of Sufficient Minimum Thickness If Special Finish Is To Be Provided And Curing, Etc. Complete. (By Weigh Batching And Mix Design For M-250 And M-300 Only. Use Of L&T, A.C. C., Ambuja, Birla Gold, Manikgad, Rajashree, Etc. Cement Is Permitted) , Bracing , Beam Of Tank Floor , Providing And Casting In Situ Cement Concrete Of Trap/Granite/Quartzite/ Gneiss Metal Of Approved Quality For Rcc Work As Per Detailed Drawings And Designs Or As Directed By Engineer-In-Charge Including Normal Dewatering, Centering, Plywood Formwork, Bully/Steel Prop-Ups, Compaction, Finishing The Formed Surfaces With Cm 1:3 Of Sufficient Minimum Thickness If Special Finish Is To Be Provided And Curing, Etc. Complete. (By Weigh Batching And Mix Design For M-250 And M-300 Only. Use Of L&T, A.C. C., Ambuja, Birla Gold, Manikgad, Rajashree, Etc. Cement Is Permitted) (Excluding M.S, Or Tor Reinforcement) For Rcc M-300 Grade Slabs / Landings / Vertical Walls Section-G-Plain And Reinforced Cement Concrete , Tank Floor Roof M-30 , Tank Roof Top M-25 , Providing Coarse Clean Sand In Filling In Foundation Trenches Or In Plinth Including Ramming And Watering In Layers Not Exceeding 150Mm Thick With All Leads Including Cost Of Materials,Labours,Royalityand Taxes All Complete As Per Building Specification And Direction Of E/I.(Mode Of Measurement-Compacted Volume). , Providing Designation 100 A One Brick Flat Soling Joints Filled With Local Sand Including Cost Of Watering, Taxes Royalty All Complete As Per Building Specification And Direction Of E/I. , Filling In Foundation Trenches And Plinth In Layers Not Exceeding 150Mm Thick, Well Watered,Rammed,Fully Compacted And Fine Dressed With Earth Obtained From Excavation Of Foundation Trenches Within A Lead Of 50M And Lift Of 1.5M All Complete As Per Building Specifications And Direction Of E/I.(Mode Of Measurement-Compacted Volume). , Providing Designation 75 A Brick Work In C.M(1:6) In Foundation And Plinth With Approved Quality Of Clean Coarse Sand Of F.M.2 To2.5 Including Providing 10Mm Thick Mortar Joints, Cost Of Screening,Scaffolding,Raking Out Joints To 15Mm Depth,Curing,Taxes And Royalty All Complete As Per Building Specification And Direction Of E/I. , Providing Designation 75A Brick Work In C.M(1:6) In Superstructure With Approved Quality Of Clean Coarse Sand Of F.M 2 To 2.5 Including Providing 10Mm Thick Mortar Joints, Cost Of Screening,Scaffolding,Raking Out Joints 15Mm Depth,Curing,Taxes And Royalty All Complete As Per Bldg. Specification And Direction Of E/I. , Providing R.C.C.M-200 In Nominal Mix Of (1:1.5:3) In Lintel With Approved Quality Of Stone Chips (20Mm To 6Mm Size) Graded And Clean Coarse Of F.M 2.5 To 3 Including Screening, Centering, Shuttering, Mixing Cement Concrete In Mixer And Placing In Position, Vibrating Striking, Curing(But Excluding The Cost Of Reinforcement),Taxes And Royalty All Complete As Per Building Specification And Direction Of E/I. , Providing Av.63 Mm Thick R.C.C M-200 In Nominal Mix Of (1:1.5:3) Chhajja With Approved Quality Of Stone Chips (20Mm To 6Mm Size) Graded And Clean Coarse Sand Of F.M 2.5 To 3 Including In Mixer And Placing In Position,Vibrating,Striking,6Mm Cement Plaster(1:4) In Ceiling And Sides Of Chhajja With Sand Of F.M 1.5, Curing(But Excluding The Cost Of Reinforcement) Taxes, And Royalty All Complete As Per Building Specification And Direction Of E/I. , Providing T.M.T Steel Reinforcement Of Different Dia Rods As Per Approved Design And Drawing Including Carriage Of M.S Bars To Work Site, Cutting Bending And Binding With Annealed Wire With Cost Of Wire, Removal Of Rust, Placing The Rods In Position All Complete As Per Building Specification And Direction Of E/I. , Supplying, Fitting And Fixing M.S Grill Made Of 20*6 Mmm.S Flats As Per Approved Design And Drawing, Properly Fabricated With Joints Continuous Fillet Welded And Finished Smooth, Carriage Of Grill To Work Site, Hoisting As Per Building Specification And Direction Of E/I. , Providing And Fixing Fan Hooks Of 16 Mm Dia M.S.Bar & 1 Meter Long Bent To Required Size And Shape, Placed In Position And Fixed In The R.C.C. Slab/Beam At The Time Ofcasting All Complete As Per Building Specification And Direction Of E/I. , Supplying, Fitting And Fixing 20 Gauge G.C.I Sheet Gate Fitted On M.S Angle Frame Of Size60*60*6 Mm Including Cost Of Fabrication, Providing Necessary Locking Arrangement With Haskal And Domny Duly Fixed In C/C(1:2:4) Blocks Of Required Size, Applying A Priming Red Lead Paint Over Steel Work, Taxes All Complete As Per Drawing Specification And Direction Of E/I. , Providing 12 Mm Cement Plaster (1:4) With Clean Coarse Sand Of F.M 1.5 Including Cost Of Screening, Curing With All Leads And Lifts Of Water,Scaffolding,Taxes And Royalty All Complete As Per Building Specification And Direction Of E/I. , Providing 12 Mm Cement Plaster (1:6) With Clean Coarse Sand Of F.M 1.5 Including Cost Of Screening, Curing With All Leads And Lifts Of Water,Scaffolding,Taxes And Royalty All Complete As Per Building Specification And Direction Of E/I. , Providing 6 Mm Cement Plaster (1:4 ) In Ceiling With Clean Coarse Sand Of F.M 1.5 Including Cost Of Screening, Curing With All Leads And Lifts Of Water,Scaffolding,Taxes And Royalty All Complete As Per Building Specification And Direction Of E/I. , Providing 12 Mm Cement Plaster (1:3) With Clean Coarse Sand Of F.M 1.5 With Floating Coat Of Neat Cement In Skirting Including Rounding Of Junctions With Floor,Curing,Taxes And Royalty All Complete As Per Building Specification And Direction Of E/I. , Providing 19 Mm Water Proof Cement Plaster (1:3) With Clean Coarse Sand Of F.M 1.5 With 5% Cico Or Any Other Approved Water Proofing Compound Including Cost Of Screening, Curing With All Leads And Lifts Of Water,Scaffolding,Taxes And Royalty All Complete As Per Building Specification And Direction Of E/I. , Providing 1.5 Mm Cement Punning Including Curing, Carriage Of Water With All Leads And Lifts As Per Building Specification And Direction Of E/I. , Providing Two Coats Of Snowcem Of Approved Shade And Make Over Old Surface Including Washing, Cleaning, Sand Papering The Wall,Scaffolding,Curing And Taxes All Complete As Per Building Specification & Direction Of E/I. , Extra For Each Coat Of Cement Wash, Distemper Paint Or Snowcem Over Exterior Surface For Each Consecutive Floor Above First Floor Including Scaffolding Etc All Complete As Per Building Specification & Direction Of E/I. , Providing Two Coats Of Synthetic Enamel Paint Of Approved Shade And Make Over Steel Surface Throughly,Scaffolding And Taxes All Papering Including Cost Of Scaffolding And Taxes All Complete As Per Building Specification & Direction Of E/I. , Providing And Fixing G.I. Pipe Railing Having 1.0 M Height Consisting 50 X 50 X 6 Mm Thick M. S. Angles As Verticals At 1.5 M C/C, And Additional Posts At Every Corner With 3 Rows Of 25 Mm Dia G.I. Pipes Of Medium Class Variety As Horizontal And Painting 3 Coats Of Oil Paint Over 1 Coat Of Anticorrosive Paint Of Approved Colour And Shade Including Cost Of All Labour, Transporting Bends To Curved Shape, Etc. Complete. , Providing And Fixing In Position M.S. Ladder 0.50 M Wide Consisting Of 75 X 10 Mm M.S. Flats As Stringers And 16 Mm Dia M.S. Bars In Double Rows As Steps Placed At 25 Cm C/C Including Cost Of Material And Labour Involved, Welding, Anchoring And Applying 3 Coat Of Anti-Corrosive Paint, Etc. Complete As Directed By Engineer-In-Charge. , Carriage Of Materials From Different Sources Or Departmental Stores To Work Site Including Loading, Transporting, Unloading And Stacking The Materials At Work Site Etc. All Complete Job. As Per Direction Of E/I. , Cement Lead 10 Km (Avg.) , Sand Lead 36 Km (Avg.) , Stone Chips Lead 11 Km (Avg.) , Steel Reinforcement Lead 10 Km (Avg.) , Bricks Lead 06 Km (Avg.) , Distribution Network & House Connection20 -40 Nos. Including Platform & Stand Post , Earth Work In Excavation In Foundation Trenches In Hard Soil (Vide Classification Soil Item B) And Disposal Of Excavated Earth As Obtained To A Distance Up To 50 Mtr. Including All Lifts, Leveling, Ramming The Foundation Trenches, Removing Roots Of Trees, Shrubs All Complete As Per Approved Design, Specification And Direction Of E/I. , Dismantling Plain Cement Concrete Work Including Stacking Serviceable Materials In Countable Stacks Within 15 M Lead And Disposal Of Unserviceable Materials With All Leads All Complete. , Providing Pccm-200 With Nominal Mix Of (1:1.5:3) With Approved Quality Of Stone Chips 20 Mm To 6 Mm Size Graded And Clean Coarse Sand Of Fm 2.5 To 3.0 Including Screening, Shuttering, Mixing Cement Concrete In Mixer And Placing In Position, Vibrating, Sticking, Curing , Taxes And Royalty All Complete As Per Specification And Direction Of E/I. , Rising Main , Manufacture, Supply And Delivery Offollowing Nominal Dia Upvc Column Pipes Including Pvc Socket (Coupler), , 65Mm Dia -Density Of Pipe 1.38 To 1.43 Gm Per Cm3 Od:74.5 To 75.2Mm Wall Thickness End:9Mm To 10.7Mm, Barrel 9Mm To 10.7 Mm, Length: 3Mtrs.Rising Main , 50 Mm Dia -Density Of Pipe 1.38 To 1.43 Gm Per Cm3 Od:87.5 To 88.2Mm Wall Thickness End:9 .8 Mm To 11.9Mm, Barrel 7.3Mm To 9 Mm, Length: 3Mtrs. Delivery Pipe , Distribution , Providing And Supplying High Density Polyethylene Pipe (Hdpe Pipe) Of 20 Mm To 225 Mm Od And Pressure 6.0 Kg/Cm2 And 10 Kg/Cm2 Suitable For Water Supply Which Is Available In All Standard Conforming To Isi -- 4984/14151/12786/13488,Iso 4427 , Din-8074Materials Rates Are Ex-Factory Excluding Transportation, Taxes And Duties. Pe-80 , Pn- 10 , 63 Mm Hdpe Pipe , 50 Mm Hdpe Pipe , 32 Mm Hdpe Pipe , 20 Mm Hdpe Pipe , Providing And Fixing Gun Metal Gate Valvewith C I Wheel Of Approved Quality(Screwed End). , 65 Mm Dia. , 50 Mm Dia. , Providing And Supplying High Density Polyethylene(Hdpe )Fittings Of 20 Mm To 225 Mm Od And Pressure 6.0 Kg/Cm2 And 10 Kg/Cm2 Suitable For Water Supply Which Is Available In All Standard Conforming To Isi -- 4984/14151/12786/13488,Iso 4427 , Din-8074Materials Rates Are Ex-Factory Excluding Transportation, Taxes And Duties. Pe-80 , Pn- 10 , Lowering, Laying And Jointing H. D. P. E./M. D.P. E. Pipes In Proper Position Including All Specials By Compression Fitting/Electro Fusion And Butt Fusion Jointing Procedure As Per Relevant Is Code Complete With All Materials For Jointing Procedure Like Electro Fusion Machine, Electric Heater/Butt Fusion Welding Machine With Hydraulic Jack, Top Loading Clamp Etc. And All Labours As Directed By Engineer In Charge As Per Is-7634 Part Ii. , For Rising , 65 Mm Hdpe Pipe , 50 Mm Hdpe Pipe , Distribution , 65 Mm Hdpe Pipe , 50 Mm Hdpe Pipe , 32 Mm Hdpe Pipe , 20 Mm Hdpe Pipe , Providing 15 Mm Dia. G.I. Pipe Tata Or Equivalent Make As Per Is 1239 (Part 1/2004) Isi Mark /Medium Quality In Stand Post. , Supplying All Materials , Labour And Tools For Fixing 15 Mm Dia G.I. Pipes With Red Lead And Yarn Of Following Nominal Bore With Screwed And Socketed Joints On Wall, Ceiling And Floor Including Supplying And Fitting Of Wall Hooks Or Pipe Clamps, Wooden Plugs, Cutting Pipes To Size And Threading Ends If Required Etc. All Complete As Per Specification And Direction Of Engineer-In-Charge. , Supplying And Fixing G.I. Fittings Of Approved Make All Complete As Per Specification And Direction Of E/I. , Elbow 15 Mm Dia. , Reducer Socket 20X15 Mm Dia. , Nipple 15 Mm Dia. , Plain Socket 15 Mm Dia. , Supplying And Fixing G.M. Ferrule Of Approved Make In Existing C.I./D.I. Main Including Drilling And Taping C.I./D.I. Main All Complete As Per Specification And Direction Of E/I. 3 Mm, 6 Mm 10 Mm Dm Ferrule Weight Not Less Than 425 Gram. , Providing And Fixing Of Male Ended C.I.Body Brass Spindle Valve And Seat Bib Cock Of Approved Quality With Extra Socketall Complete As Per Specification And Direction Of E/I. , 15 Dia And Weight Not Less Than 400 Gm , Providing And Fixing Gun Metal Full Way Valve Of Approved Quality, All Complete, As Per Specification And Direction Of E/I. , 65 Mm Dia Full Way Valve , 50 Mm Dia And Weight Not Less Than 1.5 Kg , Constructing Masonry Chamber 30X30x50 Cm Inside, In Brick Work In Cement Mortar 1:4 (1 Cement :4 Coarse Sand) For Stop Cock, With C. I. Surface Box 100X100 X75 Mm (Inside) With Hinged Cover Fixed In Cement Concrete Slab 1:2:4 Mix (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size), I/C Necessary Excavation, Foundation Concrete 1:5:10 ( 1 Cement : 5 Fine Sand : 10 Graded Stone Aggregate 40Mm Nominal Size ) And Inside Plastering With Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) 12Mm Thick, Finished With A Floating Coat Of Neat Cement Complete As Per Standard Design. With Common Burnt Clay F.P.S.(Non Modular) Bricks Of Class Designation 7.5. Full Way Valve Chamber , Providing Brick Masonry Chamber Ofinner Size 600 X 600 X 450 Mm Deep For Bore Well Protection Having 125 Mm Thick Wall And 75 Mm R.C.C Cover Including Cement Plaster Of Exposed Surface, Etc All Complete Job , Supplying Materials , Labours And Equipments For Construction Of 0.90M X 0.90 M Size P.C.C. (1:2:4) Rectangular Platform With Stand Post In House Including 12 Mm Thick Cement Plaster In C.M. (1:4) With Neat Cement Punning Over Exposed Surfaceall Complete Job, As Per Approved Design, Specification And Direction Of E/I. , Earth Work In Back Filling The Trenches After Laying Different Types And Size Of Pipes With Earth Removed During Excavation Within Initial Lead And Lift As Per Specification And Direction Of Engineer-In-Charge. , Providing Fitting & Fixing 32 Mm To 50 Mm Service Hdpe Saddleall Complete Job, As Per Approved Design, Specification And Direction Of E/I. , Carriage Of Materials From Different Sources Or Departmental Stores To Work Site Including Loading, Transporting, Unloading And Stacking The Materials At Work Site Etc. All Complete Job. As Per Direction Of E/I. , Cement Lead 10 Km (Avg.) , Sand Lead 36 Km (Avg.) , Stone Chips Lead 11 Km (Avg.) , Steel Reinforcement Lead 10 Km (Avg.) , Bricks Lead 06 Km (Avg.) , Annual Operation & Maintenance Cost Based On Existing D/T Well With Solarmotor Pump For 5 Years , O & M Cost For 1St Year (Excluding Repair Charges) , O & M Cost For 2Nd Year With Annual Repair Charges , O & M Cost For 3Rd Year , O & M Cost For 4Th Year , O & M Cost For 5Th Year , Provision Of One No Sim Card & Its Recharging Cost For Rmc (01 Sim Each Year) , Model- 03 (12000 Litre 10 M Staging) , Construction Of 125 Mm X 115 Mm X 90.0 M Deep Drilled Tube Well (2 Nos Of Dt) , Supplying All Materials, Labour And Tools And Equipment For Drilling 125 X 115 Mm Dia Bore Well In Any Kinds Of Soil And Rocks By Using D.T.H. Super Rig Machine And Ball Hammer Technology Including All Technology Inclusive Of Mobilization, Demobilization Of Rigs Air Compressor All Accessories Of Rigs Tools And Plant Labour Etc. All Complete Job Including Transportation Charge Cost Of Flushing Charge, Geographical Investigation Etc. All Complete , (A) 0.00M Up To 30.00M Depth Below G.L. In Rural Areas , (B) 30.000M Up To 120.00M Depth Beyond . In Rural Areas , Basic Rate Of 125Mmdia Blue Upvc Casingpipe Confirming To I.S.I . Latest Revision Is(12818)/2016 , Supplying All Materials, Labour And Inserting Upvc Bluepipe 125 Mm Internal Dia Casing Pipe For Protecting The Bore Hole In Over Burden Up To Hard Surface As Per Is 12818-1392 With Latest Revisionall Complete Job With Taxesas Per Specification And Direction Of E/I. , Supplying Labour Cement And Calcium Chloride Or Bentonite Solution And Equipment’S For Grouting Casing Pipe , Supplying All Tools, Equipments And Labour And Doing Washing, Flushing And Development Of Drilled Tube Well To Give Clean And Clear Water All Complete As Per Direction E/I. , Supplying Laboursand Equipment’S Including 125Mm Dia G.I. Cap & Fittingand Fixing Over Thecasing Pipe Of Bore Well Properly And Taking It Out As Per Direction Of E/I. , Supplyingmaterials And Labours For Constructing Bore Well Chamber Of 75B Designation Brick Masonry Chamber 600Mmx450mm And 750Mm Deep Internal Dimension Having 250Mm Thickness In Cement Mortar 1:6 Including 12Mm Cement Plaster 1:6 With 600Mmx475mm Rcc Cover With Earth Work In Excavation And 75Mm Thick Pcc(1:3:6) In Foundation And Refilling All Complete As Per Specification And Direction Of E/I. , 2 H.P. D.C. Solarmotor Pump Complete Set , Designing, Supplying, Installation, Testing & Commissioning With All Tools & Parts Of Following Solar Photovoltaic (Spv) Solar Submersible D.C. Water Motor Pump Suitable For Minimum 125Mm X 115Mm Bore Well As Per Mnre Guideline With Following Specifications & Accessories. , Spv Arrays Contains Specified No Of Same Capacity Type & Specification Modules Connected To Series Or Parallel To Obtained The Required Voltage & Current The Power Output Of Individual Pvmodules Should Be Minimum 200 Watt Peak. , I) The Spv Modules Should Be As Per Iec-61215 And Iec 61730 Part 1.0) , Ii) All External Parts Of Motor Pump Used In Submersible Pump Which Are In Contact Of Water Is Stainless Steel Grade 303 Or Higher As Required. , Iii) The Pv Modules Shouldbe Mounted On Metallic Structure Of Adequate Strength And Appropriate Design Which Can Withstand Load Of Modules & High Wind Pressure Up To 200Km/H. , Iv) The Module Mounting Structure Should Be Hot Dip Galvanized According To Is 4759. , V) To Enhance The Performance Of Spv Water Pumping System & Arrangement For Seasonal Tilt Angle Adjustment Should Be Provided , Vi) Necessary Arrangement Should Be Provided In Controller Automatic Start-Run-Stop Through Out The Day With Water Level Detection System. (As Per Mnre Specification) , Vii) Necessary Protection Such As Lightening Arrestor Etc. Should Be Provided To Protect The Controller & Spv , Viii) The Suction/Delivery Pipe Shall Be Upvc / H.D.P.E. Pipes Of Appropriate Size 60M Or More As Required Minimum Pressure Rating Of 8Kg/Sq Cm- Pe 100 Grade For Pump Up To 3Hp & 10 Kg/Sq Cm- Pe 100 Grade For 5 Hp. , Ix) All Cable Used Shall Be As Per Is 694. Suitable Size Of Cable Shall Be Used In Sufficient Length For Inter Connection Between The Spv Array To Spv Controller And Spv Controller To Solar Power Pump. Provision Of Cable Shall Be As Per Is 14536. , X) The Motor Pump Set Should Have A 5 Years Warranty. , Xi) Control Panel Suitable For Motor Pump With Arrangement Of Dry Run & Over Flow Protection Sensor, Float Switch & Rain Prevention Box. (As Per Mnre Specification) , Xii) The Spv Controller Must Have Ip-65 Protection Or Must Be Housed In Cabinet Having At Least Ip-65 Protection. , Xiii) The System Should Be As Per Mnre Guide Line & Ecofriendly With Suitable Arrangement To Operate New Pump Manually. , Xiv) With Third Party Inspection Before Dispatch. , Xv) Provision For Web Basedremote Monitoring Of The Pumps To Be Installed Must Be Made Through The Inbuilt Controllers . It Should Be Possible To Ascertain The Daily Water Output, The Power Generated By Pv Array ,The Up And Downtime Of The Pump During The Year, Number Of Days The Pump Was Unused Or Under Breakdown Repairs. , The Following Details Should Be Marked Indelibly On The Motor Pump Set , A) Name Of The Manufacturer Or Distinctive Logo. , B) Model Number. , C) Serial Number. , Solar Submersible Motor Pump (Spv Dc Type) , I) 1 Hp (Dc Pump) With 1800 Wp Minimum Watt P.V. Panel As Mnre Pump Head Max Shut-Off Head Up To 100 Mtrs. For Higher Or Lower Head Or In Between Various Modules Output Could Be Decided On Prorates Basis. (As Per Latest Guide Line Of Mnre) , Provision Of Solar Night Lamp. , 12000 Litre Capacityr.C.C. Water Tank (2.7 X 2.7 X 2M Internal Size) With 10 M Staging Having Utility Room At Ground Level , Earth Work In Excavation In Foundation Trenches In Ordinary Soil (Vide Classification Of Soil Item-B ) And Disposal Of Excavated Earth As Obtained To A Distance Up To 50 M Including All Lifts,Levelling,Ramming The Foundation Trenches, Removing Roots Of Trees Shrubs All Complete As Per Approved Design, Building Specification And Direction Of E/I. , Providing P.C.C.M-150 In Nominal Mix Of (1:2:4) In Foundation With Approved Quality Of Stone Chips 20Mm To 6Mm Size Graded And Clean Coarse Sand Of F.M 2.5 To 3 Including Screening, Mixing Cement Concrete In Mixer And Placing In Position,Vibrating,Curing,Taxes And Royalty All Complete As Per Building Specification Direction Of E/I. , Providing And Laying In Situ Cement Concrete Of Trap/Granite/Quartzite/ Gneiss Metal For Rcc Work In Foundation Like Raft, Grillage, Strip Foundation And Footing Of Rcc Columns And Steel Stanchions Including Normal Dewatering, Plywood Form Work, Bully/Steel Propups, Compaction, Finishing Andcuring, Etc, Complete. (By Weigh Batching And Mix Design For M-250Only. Use Of L & T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, Etc. Cement Is Permitted.) , Providing And Casting In Situ Cement Concrete Of Trap/Granite/Quartzite/ Gneiss Metal Of Approved Quality For Rcc Work As Per Detailed Drawings And Designs Or As Directed By Engineer-In-Charge Including Normal Dewatering, Centering, Plywood Formwork, Bully/Steel Prop-Ups, Compaction, Finishing The Formed Surfaces With Cm 1:3 Of Sufficient Minimum Thickness If Special Finish Is To Be Provided And Curing, Etc. Complete. (By Weigh Batching And Mix Design For M-250 And M-300 Only.Use Of L&T, A.C. C., Ambuja, Birla Gold, Manikgad, Rajashree, Etc. Cement Is Permitted) , Column From G.L To Roof Beam Of Utility Room , Column From Roof Beam To Tank Beam Of Utility Room , Column From Tank Beam To Tank Roof Of Utility Room , Providing And Casting In Situ Cement Concrete Of Trap/Granite/Quartzite/ Gneiss Metal Of Approved Quality For Rcc Work As Per Detailed Drawings And Designs Or As Directed By Engineer-In-Charge Including Normal Dewatering, Centering, Plywood Formwork, Bully/Steel Prop-Ups, Compaction, Finishing The Formed Surfaces With Cm 1:3 Of Sufficient Minimum Thickness If Special Finish Is To Be Provided And Curing, Etc. Complete. (By Weigh Batching And Mix Design For M-250 And M-300 Only. Use Of L&T, A.C. C., Ambuja, Birla Gold, Manikgad, Rajashree, Etc. Cement Is Permitted) , Bracing , Beam Of Tank Floor , Providing And Casting In Situ Cement Concrete Of Trap/Granite/Quartzite/ Gneiss Metal Of Approved Quality For Rcc Work As Per Detailed Drawings And Designs Or As Directed By Engineer-In-Charge Including Normal Dewatering, Centering, Plywood Formwork, Bully/Steel Prop-Ups, Compaction, Finishing The Formed Surfaces With Cm 1:3 Of Sufficient Minimum Thickness If Special Finish Is To Be Provided And Curing, Etc. Complete. (By Weigh Batching And Mix Design For M-250 And M-300 Only. Use Of L&T, A.C. C., Ambuja, Birla Gold, Manikgad, Rajashree, Etc. Cement Is Permitted) (Excluding M.S, Or Tor Reinforcement) For Rcc M-300 Grade Slabs / Landings / Vertical Walls Section-G-Plain And Reinforced Cement Concrete , Tank Floor Roof , Tank Roof Top , Providing Coarse Clean Sand In Filling In Foundation Trenches Or In Plinth Including Ramming And Watering In Layers Not Exceeding 150Mm Thick With All Leads Including Cost Of Materials,Labours,Royalityand Taxes All Complete As Per Building Specification And Direction Of E/I.(Mode Of Measurement-Compacted Volume). , Providing Designation 100 A One Brick Flat Soling Joints Filled With Local Sand Including Cost Of Watering, Taxes Royalty All Complete As Per Building Specification And Direction Of E/I. , Filling In Foundation Trenches And Plinth In Layers Not Exceeding 150Mm Thick, Well Watered,Rammed,Fully Compacted And Fine Dressed With Earth Obtained From Excavation Of Foundation Trenches Within A Lead Of 50M And Lift Of 1.5M All Complete As Per Building Specifications And Direction Of E/I.(Mode Of Measurement-Compacted Volume). , Providing Designation 75 A Brick Work In C.M(1:6) In Foundation And Plinth With Approved Quality Of Clean Coarse Sand Of F.M.2 To2.5 Including Providing 10Mm Thick Mortar Joints, Cost Of Screening,Scaffolding,Raking Out Joints To 15Mm Depth,Curing,Taxes And Royalty All Complete As Per Building Specification And Direction Of E/I. , Providing Designation 75A Brick Work In C.M(1:6) In Superstructure With Approved Quality Of Clean Coarse Sand Of F.M 2 To 2.5 Including Providing 10Mm Thick Mortar Joints, Cost Of Screening,Scaffolding,Raking Out Joints 15Mm Depth,Curing,Taxes And Royalty All Complete As Per Bldg. Specification And Direction Of E/I. , Providing R.C.C.M-200 In Nominal Mix Of (1:1.5:3) In Lintel With Approved Quality Of Stone Chips (20Mm To 6Mm Size) Graded And Clean Coarse Of F.M 2.5 To 3 Including Screening, Centering, Shuttering, Mixing Cement Concrete In Mixer And Placing In Position, Vibrating Striking, Curing(But Excluding The Cost Of Reinforcement),Taxes And Royalty All Complete As Per Building Specification And Direction Of E/I. , Providing Av.63 Mm Thick R.C.C M-200 In Nominal Mix Of (1:1.5:3) Chhajja With Approved Quality Of Stone Chips (20Mm To 6Mm Size) Graded And Clean Coarse Sand Of F.M 2.5 To 3 Including In Mixer And Placing In Position,Vibrating,Striking,6Mm Cement Plaster(1:4) In Ceiling And Sides Of Chhajja With Sand Of F.M 1.5, Curing(But Excluding The Cost Of Reinforcement) Taxes, And Royalty All Complete As Per Building Specification And Direction Of E/I. , Providing T.M.T Steel Reinforcement Of Different Dia Rods As Per Approved Design And Drawing Including Carriage Of M.S Bars To Work Site, Cutting Bending And Binding With Annealed Wire With Cost Of Wire, Removal Of Rust, Placing The Rods In Position All Complete As Per Building Specification And Direction Of E/I. , Supplying, Fitting And Fixing M.S Grill Made Of 20*6 Mmm.S Flats As Per Approved Design And Drawing, Properly Fabricated With Joints Continuous Fillet Welded And Finished Smooth, Carriage Of Grill To Work Site, Hoisting As Per Building Specification And Direction Of E/I. , Providing And Fixing Fan Hooks Of 16 Mm Dia M.S.Bar & 1 Meter Long Bent To Required Size And Shape, Placed In Position And Fixed In The R.C.C. Slab/Beam At The Time Ofcasting All Complete As Per Building Specification And Direction Of E/I. , Supplying, Fitting And Fixing 20 Gauge G.C.I Sheet Gate Fitted On M.S Angle Frame Of Size60*60*6 Mm Including Cost Of Fabrication, Providing Necessary Locking Arrangement With Haskal And Domny Duly Fixed In C/C(1:2:4) Blocks Of Required Size, Applying A Priming Red Lead Paint Over Steel Work, Taxes All Complete As Per Drawing Specification And Direction Of E/I. , Providing 12 Mm Cement Plaster (1:4) With Clean Coarse Sand Of F.M 1.5 Including Cost Of Screening, Curing With All Leads And Lifts Of Water,Scaffolding,Taxes And Royalty All Complete As Per Building Specification And Direction Of E/I. , Providing 12 Mm Cement Plaster (1:6) With Clean Coarse Sand Of F.M 1.5 Including Cost Of Screening, Curing With All Leads And Lifts Of Water,Scaffolding,Taxes And Royalty All Complete As Per Building Specification And Direction Of E/I. , Providing 6 Mm Cement Plaster (1:4 ) In Ceiling With Clean Coarse Sand Of F.M 1.5 Including Cost Of Screening, Curing With All Leads And Lifts Of Water,Scaffolding,Taxes And Royalty All Complete As Per Building Specification And Direction Of E/I. , Providing 12 Mm Cement Plaster (1:3) With Clean Coarse Sand Of F.M 1.5 With Floating Coat Of Neat Cement In Skirting Including Rounding Of Junctions With Floor,Curing,Taxes And Royalty All Complete As Per Building Specification And Direction Of E/I. , Providing 19 Mm Water Proof Cement Plaster (1:3) With Clean Coarse Sand Of F.M 1.5 With 5% Cico Or Any Other Approved Water Proofing Compound Including Cost Of Screening, Curing With All Leads And Lifts Of Water,Scaffolding,Taxes And Royalty All Complete As Per Building Specification And Direction Of E/I. , Providing 1.5 Mm Cement Punning Including Curing, Carriage Of Water With All Leads And Lifts As Per Building Specification And Direction Of E/I. , Providing Two Coats Of Snowcem Of Approved Shade And Make Over Old Surface Including Washing, Cleaning, Sand Papering The Wall,Scaffolding,Curing And Taxes All Complete As Per Building Specification & Direction Of E/I. , Extra For Each Coat Of Cement Wash, Distemper Paint Or Snowcem Over Exterior Surface For Each Consecutive Floor Above First Floor Including Scaffolding Etc All Complete As Per Building Specification & Direction Of E/I. , Providing Two Coats Of Synthetic Enamel Paint Of Approved Shade And Make Over Steel Surface Throughly,Scaffolding And Taxes All Papering Including Cost Of Scaffolding And Taxes All Complete As Per Building Specification & Direction Of E/I. , Providing And Fixing G.I. Pipe Railing Having 1.0 M Height Consisting 50 X 50 X 6 Mm Thick M. S. Angles As Verticals At 1.5 M C/C, And Additional Posts At Every Corner With 3 Rows Of 25 Mm Dia G.I. Pipes Of Medium Class Variety As Horizontal And Painting 3 Coats Of Oil Paint Over 1 Coat Of Anticorrosive Paint Of Approved Colour And Shade Including Cost Of All Labour, Transporting Bends To Curved Shape, Etc. Complete. , Providing And Fixing In Position M.S. Ladder 0.50 M Wide Consisting Of 75 X 10 Mm M.S. Flats As Stringers And 16 Mm Dia M.S. Bars In Double Rows As Steps Placed At 25 Cm C/C Including Cost Of Material And Labour Involved, Welding, Anchoring And Applying 3 Coat Of Anti-Corrosive Paint, Etc. Complete As Directed By Engineer-In-Charge. , Carriage Of Materials From Different Sources Or Departmental Stores To Work Site Including Loading, Transporting, Unloading And Stacking The Materials At Work Site Etc. All Complete Job. As Per Direction Of E/I. , Cement Lead 10 Km (Avg.) , Sand Lead 36 Km (Avg.) , Stone Chips Lead 11 Km (Avg.) , Steel Reinforcement Lead 10 Km (Avg.) , Bricks Lead 06 Km (Avg.) , Distribution Network & House Connection 40 - 60 Nos. Including Platform & Stand Post , Earth Work In Excavation In Foundation Trenches In Hard Soil (Vide Classification Soil Item B) And Disposal Of Excavated Earth As Obtained To A Distance Up To 50 Mtr. Including All Lifts, Leveling, Ramming The Foundation Trenches, Removing Roots Of Trees, Shrubs All Complete As Per Approved Design, Specification And Direction Of E/I. , Dismantling Plain Cement Concrete Work Including Stacking Serviceable Materials In Countable Stacks Within 15 M Lead And Disposal Of Unserviceable Materials With All Leads All Complete. , Providing Pccm-200 With Nominal Mix Of (1:1.5:3) With Approved Quality Of Stone Chips 20 Mm To 6 Mm Size Graded And Clean Coarse Sand Of Fm 2.5 To 3.0 Including Screening, Shuttering, Mixing Cement Concrete In Mixer And Placing In Position, Vibrating, Sticking, Curing , Taxes And Royalty All Complete As Per Specification And Direction Of E/I. , Rising Main , Manufacture, Supply And Delivery Offollowing Nominal Dia Upvc Column Pipes Including Pvc Socket (Coupler), , 65 Mm Dia -Density Of Pipe 1.38 To 1.43 Gm Per Cm3 Od:74.5 To 75.2Mm Wall Thickness End:9Mm To 10.7Mm, Barrel 9Mm To 10.7 Mm, Length: 3Mtrs.Rising Main , 50 Mm Dia -Density Of Pipe 1.38 To 1.43 Gm Per Cm3 Od:87.5 To 88.2Mm Wall Thickness End:9 .8 Mm To 11.9Mm, Barrel 7.3Mm To 9 Mm, Length: 3Mtrs. Delivery Pipe , Distribution , Providing And Supplying High Density Polyethylene Pipe (Hdpe Pipe) Of 20 Mm To 225 Mm Od And Pressure 6.0 Kg/Cm2 And 10 Kg/Cm2 Suitable For Water Supply Which Is Available In All Standard Conforming To Isi -- 4984/14151/12786/13488,Iso 4427 , Din-8074Materials Rates Are Ex-Factory Excluding Transportation, Taxes And Duties. Pe-80 , Pn- 10 , 63 Mm Hdpe Pipe , 50 Mm Hdpe Pipe , 32 Mm Hdpe Pipe , 20 Mm Hdpe Pipe , Providing And Fixing Gun Metal Gate Valvewith C I Wheel Of Approved Quality(Screwed End). , 65 Mm Dia. , 50 Mm Dia. , Providing And Supplying High Density Polyethylene(Hdpe )Fittings Of 20 Mm To 225 Mm Od And Pressure 6.0 Kg/Cm2 And 10 Kg/Cm2 Suitable For Water Supply Which Is Available In All Standard Conforming To Isi -- 4984/14151/12786/13488,Iso 4427 , Din-8074Materials Rates Are Ex-Factory Excluding Transportation, Taxes And Duties. Pe-80 , Pn- 10 , Lowering, Laying And Jointing H. D. P. E./M. D.P. E. Pipes In Proper Position Including All Specials By Compression Fitting/Electro Fusion And Butt Fusion Jointing Procedure As Per Relevant Is Code Complete With All Materials For Jointing Procedure Like Electro Fusion Machine, Electric Heater/Butt Fusion Welding Machine With Hydraulic Jack, Top Loading Clamp Etc. And All Labours As Directed By Engineer In Charge As Per Is-7634 Part Ii. , For Rising , 63 Mm Hdpe Pipe , 50 Mm Hdpe Pipe , Distribution , 63 Mm Hdpe Pipe , 50 Mm Hdpe Pipe , 32 Mm Hdpe Pipe , 20 Mm Hdpe Pipe , Providing 15 Mm Dia. G.I. Pipe Tata Or Equivalent Make As Per Is 1239 (Part 1/2004) Isi Mark /Medium Quality In Stand Post. , Supplying All Materials , Labour And Tools For Fixing 15 Mm Dia G.I. Pipes With Red Lead And Yarn Of Following Nominal Bore With Screwed And Socketed Joints On Wall, Ceiling And Floor Including Supplying And Fitting Of Wall Hooks Or Pipe Clamps, Wooden Plugs, Cutting Pipes To Size And Threading Ends If Required Etc. All Complete As Per Specification And Direction Of Engineer-In-Charge. , Supplying And Fixing G.I. Fittings Of Approved Make All Complete As Per Specification And Direction Of E/I. , Elbow 15 Mm Dia. , Reducer Socket 20X15 Mm Dia. , Nipple 15 Mm Dia. , Plain Socket 15 Mm Dia. , Supplying And Fixing G.M. Ferrule Of Approved Make In Existing C.I./D.I. Main Including Drilling And Taping C.I./D.I. Main All Complete As Per Specification And Direction Of E/I. 3 Mm, 6 Mm 10 Mm Dm Ferrule Weight Not Less Than 425 Gram. , Providing And Fixing Of Male Ended C.I.Body Brass Spindle Valve And Seat Bib Cock Of Approved Quality With Extra Socketall Complete As Per Specification And Direction Of E/I. , 15 Dia And Weight Not Less Than 400 Gm , Providing And Fixing Gun Metal Full Way Valve Of Approved Quality, All Complete, As Per Specification And Direction Of E/I. , 32 Mm Dia And Weight Not Less Than 700 Gms , 65 Mm Dia Full Way Valve , 50 Mm Dia And Weight Not Less Than 1.5 Kg , Constructing Masonry Chamber 30X30x50 Cm Inside, In Brick Work In Cement Mortar 1:4 (1 Cement :4 Coarse Sand) For Stop Cock, With C. I. Surface Box 100X100 X75 Mm (Inside) With Hinged Cover Fixed In Cement Concrete Slab 1:2:4 Mix (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size), I/C Necessary Excavation, Foundation Concrete 1:5:10 ( 1 Cement : 5 Fine Sand : 10 Graded Stone Aggregate 40Mm Nominal Size ) And Inside Plastering With Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) 12Mm Thick, Finished With A Floating Coat Of Neat Cement Complete As Per Standard Design. With Common Burnt Clay F.P.S.(Non Modular) Bricks Of Class Designation 7.5.Full Way Valve Chamber , Providing Brick Masonry Chamber Ofinner Size 600 X 600 X 450 Mm Deep For Bore Well Protection Having 125 Mm Thick Wall And 75 Mm R.C.C Cover Including Cement Plaster Of Exposed Surface, Etc All Complete Job , Supplying Materials , Labours And Equipments For Construction Of 0.90M X 0.90 M Size P.C.C. (1:2:4) Rectangular Platform With Stand Post In House Including 12 Mm Thick Cement Plaster In C.M. (1:4) With Neat Cement Punning Over Exposed Surfaceall Complete Job, As Per Approved Design, Specification And Direction Of E/I. , Earth Work In Back Filling The Trenches After Laying Different Types And Size Of Pipes With Earth Removed During Excavation Within Initial Lead And Lift As Per Specification And Direction Of Engineer-In-Charge. , Providing Fitting & Fixing 32 Mm To 50 Mm Service Hdpe Saddleall Complete Job, As Per Approved Design, Specification And Direction Of E/I. , Carriage Of Materials From Different Sources Or Departmental Stores To Work Site Including Loading, Transporting, Unloading And Stacking The Materials At Work Site Etc. All Complete Job. As Per Direction Of E/I. , Cement Lead 10 Km (Avg.) , Sand Lead 36 Km (Avg.) , Stone Chips Lead 11 Km (Avg.) , Steel Reinforcement Lead 10 Km (Avg.) , Bricks Lead 06 Km (Avg.) , Galvanised Chain - Link Mess Fencing Around Solar Panel Where Bore Well Is Away From Tower , Making 30 Cm( 12) Dia Bore Up To 4M Below Ground With Hand Auger Of Approved Quality In Ordinary Soil (Vide Classification Of Soil Item-A) True To Plum And Without Eccentricity In Any Stage Of Operation And Disposal Of The Exacavated Eartrh Up To 50M Lead Including All Lifts All Complete As Per Approved Design And Direction Of E/I. , Providing P.C.C.M-150 In Nominal Mix Of (1:2:4) In Foundation With Approved Quality Of Stone Chips 20Mm To 6Mm Size Graded And Clean Coarse Sand Of F.M 2.5 To 3 Including Screening,Mixing Cement Concrete In Mixer And Placing In Position, Vibrating, Curing,Taxes And Royalty All Compelete As Per Building Specification Direction Of E/I. , Labour Cost Offitting And Fixing Galvanised Chain -Link Mess Up Height Of 2 Mincluding Cost Of Staples (But Excluding The Cost Of Cement Concrete Angle Iron Posts,Its Cutting And Making Holes,Nuts And Bolts) All Complete As Per Specification And Direction Of E/I. , Drilling 6 Mm Dia Holes In M.S Angle Iron For Fixing Of Stables Etc.As Per Building Specification And Direction Of E/I. , Labour For Cutting Of M.S Angle Iron Posts To Required Length,One End Splitted As Fish Tailed In A Length Of 150 Mm Compelete As Per Building Specification And Direction Of E/I. , Supplying,Fitting And Fixing Straining Bolts With Nut Size 22Cm*10Mm Dia Tighten The Barbed Wire With Corner Post Compelete As Per Building Specification And Direction Of E/I. , Supplying,Fitting And Fixing Galvanised Chain -Link Mess Having 3 Mm Thick Wire Cell Type 40 X 40 Mm Fitted Onm.S. Angle Frame With Two Diagonals Having 25 X 25 X 5 Mm Size Angleincludingcost Of Fabrication, Providing Necessary Locking Arrangement With Haskal And Domny Duly Fixed In Angle Post,,Applying A Priming Red Lead Paint Over Steel Work,Taxesexcluding The Cost Of Galvanised Chain -Link Mess All Complete. , Cost Of Galvanised Chain -Link Mess Having 3 Mm Thick Wire Cell Type 40 X 40 Mm Wt Not Less Than 3.1 Kg / Sq M , Cost Of 50 X 50 X 6 Mm M.S. Angle , Carriage Of Materials From Different Sources Or Departmental Stores To Work Site Including Loading, Transporting, Unloading And Stacking The Materials At Work Site Etc. All Complete Job. As Per Direction Of E/I. , Cement Lead 10 Km (Avg.) , Sand Lead 36 Km (Avg.) , Stone Chips Lead 11 Km (Avg.) , Steel Reinforcement Lead 10 Km (Avg.) , Annual Operation & Maintenance Cost Based On Existing D/T Well With Solarmotor Pump For 5 Years , O & M Cost For 1St Year (Excluding Repair Charges) , O & M Cost For 2Nd Year With Annual Repair Charges , O & M Cost For 3Rd Year , O & M Cost For 4Th Year , O & M Cost For 5Th Year , Provision Of One No Sim Card & Its Recharging Cost For Rmc (01 Sim Each Year) , Model- 04 (16000 Litre 12 M Staging) , Construction Of 200 Mm X 165 Mm X 120.00 M Deep High Yield Drilled Tube Well , Hydt : Cost Of Drilling 200Mmx165mmx125 Mtr Deep Bore Well In All Kinds Of Soil And Rock In Rural Area For Installation Of Pump Bore Set With Hydraulic Dth Rig Machine, All Complete Including Supplying All Materials, Tools, Drilling Rig, Air Compressor And Equipments, As Well As Fuel, Lubricants And Cost Of Transportation Of Rig Machine And Other Vehicles Up To The Site. , (A) 0.00M Up To 50.00M Depth Below G.L. In Rural Areas , (B) Above 50.00 M Depth. In Rural Areas , Supplying All Tools, Tackles & Lowering Of 200 Mm Dia Ms Erw Casing Pipe Of 6Mm Wall Thickness Including Welding Charges, Cost Of Pipe Etc. All Complete Job. , Supplying All Materials, Labour, Tools & Equipments For Fitting & Fixing 200Mm Dia Ms Cap Over Casing Pipe Complete Job. , Supplyingmaterials And Labours For Constructing Bore Well Chamber Of 75B Designation Brick Masonry Chamber 600Mmx450mm And 750Mm Deep Internal Dimension Having 250Mm Thickness In Cement Mortar 1:6 Including 12Mm Cement Plaster 1:6 With 600Mmx475mm Rcc Cover With Earth Work In Excavation And 75Mm Thick Pcc(1:3:6) In Foundation And Refilling All Complete As Per Specification And Direction Of E/I. , 2 H.P. D.C. Solarmotor Pump Complete Set , Designing, Supplying, Installation, Testing & Commissioning With All Tools & Parts Of Following Solar Photovoltaic (Spv) Solar Submersible D.C. Water Motor Pump Suitable For Minimum 125Mm X 115Mm Bore Well As Per Mnre Guideline With Following Specifications & Accessories. , Spv Arrays Contains Specified No Of Same Capacity Type & Specification Modules Connected To Series Or Parallel To Obtained The Required Voltage & Current The Power Output Of Individual Pvmodules Should Be Minimum 200 Watt Peak. , I) The Spv Modules Should Be As Per Iec-61215 And Iec 61730 Part 1.0) , Ii) All External Parts Of Motor Pump Used In Submersible Pump Which Are In Contact Of Water Is Stainless Steel Grade 303 Or Higher As Required. , Iii) The Pv Modules Shouldbe Mounted On Metallic Structure Of Adequate Strength And Appropriate Design Which Can Withstand Load Of Modules & High Wind Pressure Up To 200Km/H. , Iv) The Module Mounting Structure Should Be Hot Dip Galvanized According To Is 4759. , V) To Enhance The Performance Of Spv Water Pumping System & Arrangement For Seasonal Tilt Angle Adjustment Should Be Provided , Vi) Necessary Arrangement Should Be Provided In Controller Automatic Start-Run-Stop Through Out The Day With Water Level Detection System. (As Per Mnre Specification) , Vii) Necessary Protection Such As Lightening Arrestor Etc. Should Be Provided To Protect The Controller & Spv , Viii) The Suction/Delivery Pipe Shall Be Upvc / H.D.P.E. Pipes Of Appropriate Size 60M Or More As Required Minimum Pressure Rating Of 8Kg/Sq Cm- Pe 100 Grade For Pump Up To 3Hp & 10 Kg/Sq Cm- Pe 100 Grade For 5 Hp. , Ix) All Cable Used Shall Be As Per Is 694. Suitable Size Of Cable Shall Be Used In Sufficient Length For Inter Connection Between The Spv Array To Spv Controller And Spv Controller To Solar Power Pump. Provision Of Cable Shall Be As Per Is 14536. , X) The Motor Pump Set Should Have A 5 Years Warranty. , Xi) Control Panel Suitable For Motor Pump With Arrangement Of Dry Run & Over Flow Protection Sensor, Float Switch & Rain Prevention Box. (As Per Mnre Specification) , Xii) The Spv Controller Must Have Ip-65 Protection Or Must Be Housed In Cabinet Having At Least Ip-65 Protection. , Xiii) The System Should Be As Per Mnre Guide Line & Ecofriendly With Suitable Arrangement To Operate New Pump Manually. , Xiv) With Third Party Inspection Before Dispatch. , Xv) Provision For Web Basedremote Monitoring Of The Pumps To Be Installed Must Be Made Through The Inbuilt Controllers . It Should Be Possible To Ascertain The Daily Water Output, The Power Generated By Pv Array ,The Up And Downtime Of The Pump During The Year, Number Of Days The Pump Was Unused Or Under Breakdown Repairs. , The Following Details Should Be Marked Indelibly On The Motor Pump Set , A) Name Of The Manufacturer Or Distinctive Logo. , B) Model Number. , C) Serial Number. , Solar Submersible Motor Pump (Spv Dc Type) , I) 2 Hp (Dc Pump) With 1800 Wp Minimum Watt P.V. Panel As Mnre Pump Head Max Shut-Off Head Up To 100 Mtrs. For Higher Or Lower Head Or In Between Various Modules Output Could Be Decided On Prorates Basis. (As Per Latest Guide Line Of Mnre) , Provision Of Solar Night Lamp. , 16000 Litre Capacityr.C.C. Water Tank (2.7 X 2.7 X 2M Internal Size) With 12 M Staging Havingutility Room At Ground Level , Earth Work In Excavation In Foundation Trenches In Ordinary Soil (Vide Classification Of Soil Item-B ) And Disposal Of Excavated Earth As Obtained To A Distance Up To 50 M Including All Lifts,Levelling,Ramming The Foundation Trenches, Removing Roots Of Trees Shrubs All Complete As Per Approved Design, Building Specification And Direction Of E/I. , Providing P.C.C.M-150 In Nominal Mix Of (1:2:4) In Foundation With Approved Quality Of Stone Chips 20Mm To 6Mm Size Graded And Clean Coarse Sand Of F.M 2.5 To 3 Including Screening, Mixing Cement Concrete In Mixer And Placing In Position,Vibrating,Curing,Taxes And Royalty All Complete As Per Building Specification Direction Of E/I. , Providing And Laying In Situ Cement Concrete Of Trap/Granite/Quartzite/ Gneiss Metal For Rcc Work In Foundation Like Raft, Grillage, Strip Foundation And Footing Of Rcc Columns And Steel Stanchions Including Normal Dewatering, Plywood Form Work, Bully/Steel Propups, Compaction, Finishing Andcuring, Etc, Complete. (By Weigh Batching And Mix Design For M-250Only. Use Of L & T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, Etc. Cement Is Permitted.) , Providing And Casting In Situ Cement Concrete Of Trap/Granite/Quartzite/ Gneiss Metal Of Approved Quality For Rcc Work As Per Detailed Drawings And Designs Or As Directed By Engineer-In-Charge Including Normal Dewatering, Centering, Plywood Formwork, Bully/Steel Prop-Ups, Compaction, Finishing The Formed Surfaces With Cm 1:3 Of Sufficient Minimum Thickness If Special Finish Is To Be Provided And Curing, Etc. Complete. (By Weigh Batching And Mix Design For M-250 And M-300 Only.Use Of L&T, A.C. C., Ambuja, Birla Gold, Manikgad, Rajashree, Etc. Cement Is Permitted) , Column From G.L To Roof Beam Of Utility Room , Column From Roof Beam To 2Nd Bracing Beam Of Utility Room , Column From 2Nd Bracing Beam To 3Rd Bracing Beam , Column From 3Rd Bracing Beam To Tank Base , Providing And Casting In Situ Cement Concrete Of Trap/Granite/Quartzite/ Gneiss Metal Of Approved Quality For Rcc Work As Per Detailed Drawings And Designs Or As Directed By Engineer-In-Charge Including Normal Dewatering, Centering, Plywood Formwork, Bully/Steel Prop-Ups, Compaction, Finishing The Formed Surfaces With Cm 1:3 Of Sufficient Minimum Thickness If Special Finish Is To Be Provided And Curing, Etc. Complete. (By Weigh Batching And Mix Design For M-250 And M-300 Only. Use Of L&T, A.C. C., Ambuja, Birla Gold, Manikgad, Rajashree, Etc. Cement Is Permitted) , Bracing , Beam Of Tank Floor , Providing And Casting In Situ Cement Concrete Of Trap/Granite/Quartzite/ Gneiss Metal Of Approved Quality For Rcc Work As Per Detailed Drawings And Designs Or As Directed By Engineer-In-Charge Including Normal Dewatering, Centering, Plywood Formwork, Bully/Steel Prop-Ups, Compaction, Finishing The Formed Surfaces With Cm 1:3 Of Sufficient Minimum Thickness If Special Finish Is To Be Provided And Curing, Etc. Complete. (By Weigh Batching And Mix Design For M-250 And M-300 Only. Use Of L&T, A.C. C., Ambuja, Birla Gold, Manikgad, Rajashree, Etc. Cement Is Permitted) (Excluding M.S, Or Tor Reinforcement) For Rcc M-300 Grade Slabs / Landings / Vertical Walls Section-G-Plain And Reinforced Cement Concrete , Tank Floor Roof , Tank Roof Top , Providing Coarse Clean Sand In Filling In Foundation Trenches Or In Plinth Including Ramming And Watering In Layers Not Exceeding 150Mm Thick With All Leads Including Cost Of Materials,Labours,Royalityand Taxes All Complete As Per Building Specification And Direction Of E/I.(Mode Of Measurement-Compacted Volume). , Providing Designation 100 A One Brick Flat Soling Joints Filled With Local Sand Including Cost Of Watering, Taxes Royalty All Complete As Per Building Specification And Direction Of E/I. , Filling In Foundation Trenches And Plinth In Layers Not Exceeding 150Mm Thick, Well Watered,Rammed,Fully Compacted And Fine Dressed With Earth Obtained From Excavation Of Foundation Trenches Within A Lead Of 50M And Lift Of 1.5M All Complete As Per Building Specifications And Direction Of E/I.(Mode Of Measurement-Compacted Volume). , Providing Designation 75 A Brick Work In C.M(1:6) In Foundation And Plinth With Approved Quality Of Clean Coarse Sand Of F.M.2 To2.5 Including Providing 10Mm Thick Mortar Joints, Cost Of Screening,Scaffolding,Raking Out Joints To 15Mm Depth,Curing,Taxes And Royalty All Complete As Per Building Specification And Direction Of E/I. , Providing Designation 75A Brick Work In C.M(1:6) In Superstructure With Approved Quality Of Clean Coarse Sand Of F.M 2 To 2.5 Including Providing 10Mm Thick Mortar Joints, Cost Of Screening,Scaffolding,Raking Out Joints 15Mm Depth,Curing,Taxes And Royalty All Complete As Per Bldg. Specification And Direction Of E/I. , Providing R.C.C.M-200 In Nominal Mix Of (1:1.5:3) In Lintel With Approved Quality Of Stone Chips (20Mm To 6Mm Size) Graded And Clean Coarse Of F.M 2.5 To 3 Including Screening, Centering, Shuttering, Mixing Cement Concrete In Mixer And Placing In Position, Vibrating Striking, Curing(But Excluding The Cost Of Reinforcement),Taxes And Royalty All Complete As Per Building Specification And Direction Of E/I. , Providing Av.63 Mm Thick R.C.C M-200 In Nominal Mix Of (1:1.5:3) Chhajja With Approved Quality Of Stone Chips (20Mm To 6Mm Size) Graded And Clean Coarse Sand Of F.M 2.5 To 3 Including In Mixer And Placing In Position,Vibrating,Striking,6Mm Cement Plaster(1:4) In Ceiling And Sides Of Chhajja With Sand Of F.M 1.5, Curing(But Excluding The Cost Of Reinforcement) Taxes, And Royalty All Complete As Per Building Specification And Direction Of E/I. , Providing T.M.T Steel Reinforcement Of Different Dia Rods As Per Approved Design And Drawing Including Carriage Of M.S Bars To Work Site, Cutting Bending And Binding With Annealed Wire With Cost Of Wire, Removal Of Rust, Placing The Rods In Position All Complete As Per Building Specification And Direction Of E/I. , Supplying, Fitting And Fixing M.S Grill Made Of 20*6 Mmm.S Flats As Per Approved Design And Drawing, Properly Fabricated With Joints Continuous Fillet Welded And Finished Smooth, Carriage Of Grill To Work Site, Hoisting As Per Building Specification And Direction Of E/I. , Providing And Fixing Fan Hooks Of 16 Mm Dia M.S.Bar & 1 Meter Long Bent To Required Size And Shape, Placed In Position And Fixed In The R.C.C. Slab/Beam At The Time Ofcasting All Complete As Per Building Specification And Direction Of E/I. , Supplying, Fitting And Fixing 20 Gauge G.C.I Sheet Gate Fitted On M.S Angle Frame Of Size60*60*6 Mm Including Cost Of Fabrication, Providing Necessary Locking Arrangement With Haskal And Domny Duly Fixed In C/C(1:2:4) Blocks Of Required Size, Applying A Priming Red Lead Paint Over Steel Work, Taxes All Complete As Per Drawing Specification And Direction Of E/I. , Providing 12 Mm Cement Plaster (1:4) With Clean Coarse Sand Of F.M 1.5 Including Cost Of Screening, Curing With All Leads And Lifts Of Water,Scaffolding,Taxes And Royalty All Complete As Per Building Specification And Direction Of E/I. , Providing 12 Mm Cement Plaster (1:6) With Clean Coarse Sand Of F.M 1.5 Including Cost Of Screening, Curing With All Leads And Lifts Of Water,Scaffolding,Taxes And Royalty All Complete As Per Building Specification And Direction Of E/I. , Providing 6 Mm Cement Plaster (1:4 ) In Ceiling With Clean Coarse Sand Of F.M 1.5 Including Cost Of Screening, Curing With All Leads And Lifts Of Water,Scaffolding,Taxes And Royalty All Complete As Per Building Specification And Direction Of E/I. , Providing 12 Mm Cement Plaster (1:3) With Clean Coarse Sand Of F.M 1.5 With Floating Coat Of Neat Cement In Skirting Including Rounding Of Junctions With Floor,Curing,Taxes And Royalty All Complete As Per Building Specification And Direction Of E/I. , Providing 19 Mm Water Proof Cement Plaster (1:3) With Clean Coarse Sand Of F.M 1.5 With 5% Cico Or Any Other Approved Water Proofing Compound Including Cost Of Screening, Curing With All Leads And Lifts Of Water,Scaffolding,Taxes And Royalty All Complete As Per Building Specification And Direction Of E/I. , Providing 1.5 Mm Cement Punning Including Curing, Carriage Of Water With All Leads And Lifts As Per Building Specification And Direction Of E/I. , Providing Two Coats Of Snowcem Of Approved Shade And Make Over Old Surface Including Washing, Cleaning, Sand Papering The Wall,Scaffolding,Curing And Taxes All Complete As Per Building Specification & Direction Of E/I. , Extra For Each Coat Of Cement Wash, Distemper Paint Or Snowcem Over Exterior Surface For Each Consecutive Floor Above First Floor Including Scaffolding Etc All Complete As Per Building Specification & Direction Of E/I. , Providing Two Coats Of Synthetic Enamel Paint Of Approved Shade And Make Over Steel Surface Throughly,Scaffolding And Taxes All Papering Including Cost Of Scaffolding And Taxes All Complete As Per Building Specification & Direction Of E/I. , Providing And Fixing G.I. Pipe Railing Having 1.0 M Height Consisting 50 X 50 X 6 Mm Thick M. S. Angles As Verticals At 1.5 M C/C, And Additional Posts At Every Corner With 3 Rows Of 25 Mm Dia G.I. Pipes Of Medium Class Variety As Horizontal And Painting 3 Coats Of Oil Paint Over 1 Coat Of Anticorrosive Paint Of Approved Colour And Shade Including Cost Of All Labour, Transporting Bends To Curved Shape, Etc. Complete. , Providing And Fixing In Position M.S. Ladder 0.50 M Wide Consisting Of 75 X 10 Mm M.S. Flats As Stringers And 16 Mm Dia M.S. Bars In Double Rows As Steps Placed At 25 Cm C/C Including Cost Of Material And Labour Involved, Welding, Anchoring And Applying 3 Coat Of Anti-Corrosive Paint, Etc. Complete As Directed By Engineer-In-Charge. , Carriage Of Materials From Different Sources Or Departmental Stores To Work Site Including Loading, Transporting, Unloading And Stacking The Materials At Work Site Etc. All Complete Job. As Per Direction Of E/I. , Cement Lead 10 Km (Avg.) , Sand Lead 36 Km (Avg.) , Stone Chips Lead 11 Km (Avg.) , Steel Reinforcement Lead 10 Km (Avg.) , Bricks Lead 06 Km (Avg.) , Distribution Network & House Connection60 - 80 Nos. Including Platform & Stand Post , Earth Work In Excavation In Foundation Trenches In Hard Soil (Vide Classification Soil Item B) And Disposal Of Excavated Earth As Obtained To A Distance Up To 50 Mtr. Including All Lifts, Leveling, Ramming The Foundation Trenches, Removing Roots Of Trees, Shrubs All Complete As Per Approved Design, Specification And Direction Of E/I. , Dismantling Plain Cement Concrete Work Including Stacking Serviceable Materials In Countable Stacks Within 15 M Lead And Disposal Of Unserviceable Materials With All Leads All Complete. , Providing Pccm-200 With Nominal Mix Of (1:1.5:3) With Approved Quality Of Stone Chips 20 Mm To 6 Mm Size Graded And Clean Coarse Sand Of Fm 2.5 To 3.0 Including Screening, Shuttering, Mixing Cement Concrete In Mixer And Placing In Position, Vibrating, Sticking, Curing , Taxes And Royalty All Complete As Per Specification And Direction Of E/I. , Rising Main , Manufacture, Supply And Delivery Offollowing Nominal Dia Upvc Column Pipes Including Pvc Socket (Coupler), , 65 Mm Dia -Density Of Pipe 1.38 To 1.43 Gm Per Cm3 Od:74.5 To 75.2Mm Wall Thickness End:9Mm To 10.7Mm, Barrel 9Mm To 10.7 Mm, Length: 3Mtrs.Rising Main , 80 Mm Dia -Density Of Pipe 1.38 To 1.43 Gm Per Cm3 Od:87.5 To 88.2Mm Wall Thickness End:9 .8 Mm To 11.9Mm, Barrel 7.3Mm To 9 Mm, Length: 3Mtrs. Delivery Pipe , Distribution , Providing And Supplying High Density Polyethylene Pipe (Hdpe Pipe) Of 20 Mm To 225 Mm Od And Pressure 6.0 Kg/Cm2 And 10 Kg/Cm2 Suitable For Water Supply Which Is Available In All Standard Conforming To Isi -- 4984/14151/12786/13488,Iso 4427 , Din-8074Materials Rates Are Ex-Factory Excluding Transportation, Taxes And Duties. Pe-80 , Pn- 10 , 63 Mm Hdpe Pipe , 50 Mm Hdpe Pipe , 32 Mm Hdpe Pipe , 20 Mm Hdpe Pipe , Providing And Fixing Gun Metal Gate Valvewith C I Wheel Of Approved Quality(Screwed End). , 80 Mm Dia. , 65 Mm Dia. , Providing And Supplying High Density Polyethylene(Hdpe )Fittings Of 20 Mm To 225 Mm Od And Pressure 6.0 Kg/Cm2 And 10 Kg/Cm2 Suitable For Water Supply Which Is Available In All Standard Conforming To Isi -- 4984/14151/12786/13488,Iso 4427 , Din-8074Materials Rates Are Ex-Factory Excluding Transportation, Taxes And Duties. Pe-80 , Pn- 10 , Lowering, Laying And Jointing H. D. P. E./M. D.P. E. Pipes In Proper Position Including All Specials By Compression Fitting/Electro Fusion And Butt Fusion Jointing Procedure As Per Relevant Is Code Complete With All Materials For Jointing Procedure Like Electro Fusion Machine, Electric Heater/Butt Fusion Welding Machine With Hydraulic Jack, Top Loading Clamp Etc. And All Labours As Directed By Engineer In Charge As Per Is-7634 Part Ii. , For Rising , 80 Mm Hdpe Pipe , 63 Mm Hdpe Pipe , Distribution , 63 Mm Hdpe Pipe , 50 Mm Hdpe Pipe , 32 Mm Hdpe Pipe , 20 Mm Hdpe Pipe , Providing 15 Mm Dia. G.I. Pipe Tata Or Equivalent Make As Per Is 1239 (Part 1/2004) Isi Mark /Medium Quality In Stand Post. , Supplying All Materials , Labour And Tools For Fixing 15 Mm Dia G.I. Pipes With Red Lead And Yarn Of Following Nominal Bore With Screwed And Socketed Joints On Wall, Ceiling And Floor Including Supplying And Fitting Of Wall Hooks Or Pipe Clamps, Wooden Plugs, Cutting Pipes To Size And Threading Ends If Required Etc. All Complete As Per Specification And Direction Of Engineer-In-Charge. , Supplying And Fixing G.I. Fittings Of Approved Make All Complete As Per Specification And Direction Of E/I. , Elbow 15 Mm Dia. , Reducer Socket 20X15 Mm Dia. , Nipple 15 Mm Dia. , Plain Socket 15 Mm Dia. , Supplying And Fixing G.M. Ferrule Of Approved Make In Existing C.I./D.I. Main Including Drilling And Taping C.I./D.I. Main All Complete As Per Specification And Direction Of E/I. 3 Mm, 6 Mm 10 Mm Dm Ferrule Weight Not Less Than 425 Gram. , Providing And Fixing Of Male Ended C.I.Body Brass Spindle Valve And Seat Bib Cock Of Approved Quality With Extra Socketall Complete As Per Specification And Direction Of E/I. , 15 Dia And Weight Not Less Than 400 Gm , Providing And Fixing Gun Metal Full Way Valve Of Approved Quality, All Complete, As Per Specification And Direction Of E/I. , 32 Mm Dia And Weight Not Less Than 700 Gms , 65 Mm Dia Full Way Valve , 50 Mm Dia And Weight Not Less Than 1.5 Kg , Constructing Masonry Chamber 30X30x50 Cm Inside, In Brick Work In Cement Mortar 1:4 (1 Cement :4 Coarse Sand) For Stop Cock, With C. I. Surface Box 100X100 X75 Mm (Inside) With Hinged Cover Fixed In Cement Concrete Slab 1:2:4 Mix (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size), I/C Necessary Excavation, Foundation Concrete 1:5:10 ( 1 Cement : 5 Fine Sand : 10 Graded Stone Aggregate 40Mm Nominal Size ) And Inside Plastering With Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) 12Mm Thick, Finished With A Floating Coat Of Neat Cement Complete As Per Standard Design. With Common Burnt Clay F.P.S.(Non Modular) Bricks Of Class Designation 7.5.Full Way Valve Chamber , Providing Brick Masonry Chamber Ofinner Size 600 X 600 X 450 Mm Deep For Bore Well Protection Having 125 Mm Thick Wall And 75 Mm R.C.C Cover Including Cement Plaster Of Exposed Surface, Etc All Complete Job , Supplying Materials , Labours And Equipments For Construction Of 0.90M X 0.90 M Size P.C.C. (1:2:4) Rectangular Platform With Stand Post In House Including 12 Mm Thick Cement Plaster In C.M. (1:4) With Neat Cement Punning Over Exposed Surfaceall Complete Job, As Per Approved Design, Specification And Direction Of E/I. , Earth Work In Back Filling The Trenches After Laying Different Types And Size Of Pipes With Earth Removed During Excavation Within Initial Lead And Lift As Per Specification And Direction Of Engineer-In-Charge. , Providing Fitting & Fixing 32 Mm To 50 Mm Service Hdpe Saddleall Complete Job, As Per Approved Design, Specification And Direction Of E/I. , Carriage Of Materials From Different Sources Or Departmental Stores To Work Site Including Loading, Transporting, Unloading And Stacking The Materials At Work Site Etc. All Complete Job. As Per Direction Of E/I. , Cement Lead 10 Km (Avg.) , Sand Lead 36 Km (Avg.) , Stone Chips Lead 11 Km (Avg.) , Steel Reinforcement Lead 10 Km (Avg.) , Bricks Lead 06 Km (Avg.) , Galvanised Chain Link Mess Fencing Around Solar Panel Where Bore Well Is Away From Tower , Making 30 Cm( 12) Dia Bore Up To 4M Below Ground With Hand Auger Of Approved Quality In Ordinary Soil (Vide Classification Of Soil Item-A) True To Plum And Without Eccentricity In Any Stage Of Operation And Disposal Of The Exacavated Eartrh Up To 50M Lead Including All Lifts All Complete As Per Approved Design And Direction Of E/I. , Providing P.C.C.M-150 In Nominal Mix Of (1:2:4) In Foundation With Approved Quality Of Stone Chips 20Mm To 6Mm Size Graded And Clean Coarse Sand Of F.M 2.5 To 3 Including Screening,Mixing Cement Concrete In Mixer And Placing In Position, Vibrating, Curing,Taxes And Royalty All Compelete As Per Building Specification Direction Of E/I. , Labour Cost Offitting And Fixing Galvanised Chain -Link Mess Up Height Of 2 Mincluding Cost Of Staples (But Excluding The Cost Of Cement Concrete Angle Iron Posts,Its Cutting And Making Holes,Nuts And Bolts) All Complete As Per Specification And Direction Of E/I. , Drilling 6 Mm Dia Holes In M.S Angle Iron For Fixing Of Stables Etc.As Per Building Specification And Direction Of E/I. , Labour For Cutting Of M.S Angle Iron Posts To Required Length,One End Splitted As Fish Tailed In A Length Of 150 Mm Compelete As Per Building Specification And Direction Of E/I. , Supplying,Fitting And Fixing Straining Bolts With Nut Size 22Cm*10Mm Dia Tighten The Barbed Wire With Corner Post Compelete As Per Building Specification And Direction Of E/I. , Supplying,Fitting And Fixing Galvanised Chain -Link Mess Having 3 Mm Thick Wire Cell Type 40 X 40 Mm Fitted Onm.S. Angle Frame With Two Diagonals Having 25 X 25 X 5 Mm Size Angleincludingcost Of Fabrication, Providing Necessary Locking Arrangement With Haskal And Domny Duly Fixed In Angle Post,,Applying A Priming Red Lead Paint Over Steel Work,Taxesexcluding The Cost Of Galvanised Chain -Link Mess All Complete. , Cost Of Galvanised Chain -Link Mess Having 3 Mm Thick Wire Cell Type 40 X 40 Mm Wt Not Less Than 3.1 Kg / Sq M , Cost Of 50 X 50 X 6 Mm M.S. Angle , Carriage Of Materials From Different Sources Or Departmental Stores To Work Site Including Loading, Transporting, Unloading And Stacking The Materials At Work Site Etc. All Complete Job. As Per Direction Of E/I. , Cement Lead 10 Km (Avg.) , Sand Lead 36 Km (Avg.) , Stone Chips Lead 11 Km (Avg.) , Steel Reinforcement Lead 10 Km (Avg.) , Annual Operation & Maintenance Cost Based On Existing D/T Well With Solarmotor Pump For 5 Years , O & M Cost For 1St Year (Excluding Repair Charges) , O & M Cost For 2Nd Year With Annual Repair Charges , O & M Cost For 3Rd Year , O & M Cost For 4Th Year , O & M Cost For 5Th Year , Provision Of One No Sim Card & Its Recharging Cost For Rmc , 18% Gst , Labour Cess
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 8
34.
Drinking Water Supply and Sanitation #9041155 Technical Bid
Construction For Drinking Water Facility In School Through Hydt With Motor Submersible Pump Set. Under Drinking Water Sanitation Division No 2 Giridih On Turn Key Basis Block Giridih Group No Gir-School-1 , Costofdrilling200 Mm X 165 Mm X 150Mtr M Deep Bore Well In All Kinds Of Soil And Rock In Rural Areas For Installation Of Pump Set With Hydraulic Dth Rig Machine, All Complete Including Supplying All Material Tools Drilling Rig And Air Compressor And Equipments As Well As Fuel Lubricants And Cost Of Transportation Of Rig Machine And Other Vehicles Up To Site Including Cost Of Flushing Charges, Geological Investigation Etc. All Complete As Per Direction Of E/I. 0.00 To 50.00 M , Depth 51.00M - 150.00M , Supplying All Tools, Tackles & Lowering Of 200Mm Dia Ms Casing Pipe Including Cost Of Pipe Etc. Including All Taxes, Vat, Excise Duty, Freight Charges With Inspection Charges Etc. As Aplicable,All Complete Including Carriage To Work Site. , Supplying All Materials Labours, Tools & Equipments For Fitting & Fixing 200Mm Dia M.S. Cap Over Casing Pipe Etc. , Civil Portion Supplying All Tools, Equipments And Labours And Lowering 32Mm Dia G.I. Suspension Pipes In 3 Mtrs. Length In The Drilling Bore Of The Tube Well Etc. All Complete Job As Per Direction Of E/I. , Providing Lobours And Equipments Forfitting And Fixing The Deep Well Cylinderassembly With Necessary Connecting Rods Including Jointing Materials Nitrile Rubber Bucket All Tools And Plants Etc Required For The Job For Low Water Level All Comepete Job As Per Specification And Direction Of E/I. , Providing All Labours & Equipments For Fitting Fixing Of Deep Well Hand Pump India Mark-Ii Including Supplying All Tools And Plant Required For The All Job Complete As Per Specification And Direction Of E/I. , Supplying All Materials Including Cement Of Approved Quality, Labours Tools For Constricting 1.85 M Dia. Circular P.C.C. (1:2:4) Platformincluding 12 Mm Thick Cementplaster The Exposed Surface (1:4) With Neat Cement Punningincluding Providing Necessary Shuttering Curing And Carriage Of Materials To Different Tube Well Sites Etc As Per Unicef Design And Direction Of E/I. , Supplying All Materials Labours And Equpments For Constructing Pcc(1:2:4)Drain As Per Unicef Design Etc All Complete , Cost Of Materials Supplying Extra Deep Well Hand Pump Complete Sets With Cylinder Assembly& Connecting Rod (12 Pcs) As Per Is : 15500 Part-2/ 2004(Basic Rate) . , Cost Of 32Mm Dia G.I. Pipe 3 M. Long Screwed At Both Ends With Seamless Socket As Per Is: 1239Including All Taxes Royalty And Contractor Profit Etc , Reducer Cap For Instatlation Of Hand Pump , Supplying All Materials Tools & Labours For Fitting & Fixing Control Pannel Board, 1No. Star Dealta Air Beak Selector Fully Automatic With Build In Single Phase Prevendor1 No. 3 Phase M.C.C. B Suitable With Suitable Size Of Copper Wire And Connectors Etc. , Supplying & Commissiong Of 5 K.V.A Staiblizer (Range 90 V-300V) Three Phase With Cable, Chnge Over Switch For Submersible Pump Etc. All Comp. As Per Specification And Direction Of E/I. , E/W In Exavation (As Per I.S 3114/1965) For Laying Of 32Mm Dia G.I Pipes So As 1.0 M Av. Cover The Socket Of Pipe ………….. Do ……. Etc All Comp. As Per S/D Of E/I. , E/W In Back Filling In Trenches After Laying Different Type & Size Of Pipe With Eath Remove During Excavation Within Initial Lead & Lift As Per Dirction Of E/I. , Supplying All Tools, Labour, Euipment For Supplying Fitting & Fixingsubmersible Pump Set 1.50 H.P Single Phase With Statrer And Pannel Board According To I.S.I Mark Etc All Comp. Job. 150Mm Dia Bonze Impellar , Providing Fitting & Fixing 3 Core 2.5 Sqm Flate Copper Cable For Submersible Motor Pump. , Providing & Fixing 20Mm Nylon Rope For Hoisting Thesubmersible Motor Pump In Bore Well. , Supplying Upvc Pipe Approved I.S.I Make Etc As Per S/D Of E/I. (For Column Pipe) (A)32Mm Dia Column Pipe 65M , Supplying All Materials ,Labours And Laying G.I. Medium Pipesofapproved Make In Trenches With Red Lead And Yarn With G.I. Socket And Screw Joints And Cutting Pipes To Sizes And Threading Ends Where Necessary Etc. All Complete As Per Specification And Direction Of Engineer-In-Charge A) 32Mm Dia , B) 25Mm Dia , Supplying And Fixing G.I. Fitting Of Approved Make All Complete As Per Specification And Direction Of Engineer-In-Charge.(I)32 Mm Gi Elbow , (Ii)32Mmreducing Socket , (Iii)32Mm Union Socket , (V)32Mmtee , (Ii)25Mmreducing Socket , (V)25Mmtee , (Vii)25 Mm Jam Nut , 15Mm Nipple , 15Mm Socket , Providing And Fixing Of Male Ended C.I.Body Brass Spindle Valve And Seat Bib Cock Of Approved Quality With Extra Socketall Complete As Per Specification And Direction Of E/I. , Providing & Fixing Gm Non-Return Valve Of Approved Quality As Per Specification & Direction Of E/I. 32 Mm Dia , Providing And Fixing Gun Metal Full Way Valves Of Approved Make All Complete As Per Specification And Direction Of Engineer-In-Charge 32 Mm Dia G.M. Full Way Valve Weight Not Less Than 1.5 Kg , Providing Polyvinyle Water Storage Tank(1000 X 2 No= 2000) Of I.S.I Mark (Himgiri/Gangotri) Etc With Cover And Locking Arrangement System Etc. All Comp. Job. , Making Holes In Walls For Laying G.I Pipes And Restoring The Same After Pipe Laying As Per Specification And Direction Of E./I 125Mm Thick , Providing Fitting & Fixing 2 Core 2.5 Sqm Copper Cable Forelectric Connection. , Supplying All Materials Tools Labours And Laying Ofgi Pipe Tata Or Equivalent 32 Mm Dia (In Trench ) , 15 Mm Dia (On Wall) , Supplyingfitting & Fixing.Gifittings Fullway Valve 32Mm , Union Socket 32Mm , Gi Elbow 32Mm , Gi Elbow 15Mm , Gi Tee 32Mm , Gi Tee 15Mm , R/Socket 32Mm , Socket 32Mm , Socket 15Mm , Nipple 15Mm , Earth Work In Excavation In Foundation Trenchesin Hard Soil (Vide Classification Of Soil Item B) And Disposal Of Excavated Earth As Obtained To A Distance Up To 50M Including All Lifts, Leveling, Ramming The Foundation Trenches, Removing Roots Of Trees, Shrubs All Complete As Per Approved Design As Per Building Specification And Direction Of E/I. , Providing Coarse Clean Sand In Filling In Foundation Trenches Or In Lintin Including Ramming And Watering In Layers Not Exceeding 150Mm Thicks With All Leads And Lifts Including Cost Of All Materials, Labours Royalty And Taxes All Complete As Per Building Specification And Direction Of E/I. , Providing Designation 75Aone Brick Flat Soiling Joints Filled With Local Sand Including Cost Of Watering Taxes Royalty All Complete As Per Building Specification And Direction Of E/I. , Providing R.C.C.M - 200 With Nominal Mix Of (1:1.5:3) In Foundation And Plinth With Approved Quality Of Stone Chips 20 Mm To 6 Mm Size Graded And Clean Coarse Sand Of F.M. 2.5 To 3 Including Screening, Shuttering, Mixing Cement Concrete In Mixer And Placing In Position, Vibrating, Striking, Curing (But Excluding The Cost Of Reinforcement) Taxes And Royalty All Complete As Per Building Specification And Direction Of E/L. , Providing R.C.C.M- 200 With Nominal Mix (1:1.5:3) In Columns With Approved Quality Of Stone Chips 20Mm To 6Mm Size Graded And Clean Coarse Sand Of F.M.2.5 To 3 Including, Screening Shuttering Mixing Cement Concrete In Mixer And Placing In Position Vibrating, Striking, Curing Taxes Androyalty All Complete As Per Building Specification And Direction Of E/I , Providing R.C.C.M- 200 With Nominal Mix (1:1:5:3) In Roof Slab With Approved Quality Of Stone Chips 20Mm To 6Mm Size Graded And Clean Coarse Sand Of F.M.2.5 To 3 Including, Screening Shuttering Mixing Cement Concrete In Mixer And Placing In Position Vibrating, Striking, Curing Taxes Androyalty All Complete As Per Building Specification And Direction Of E/I , Dismantling Old Plaster And Pointing In Cement Or Lime And Raking Out Joints To 15 Mm. Depth, Watering And Disposal Of Unserviceable Materials With All Leads All Complete As Per Direction Of E/L , Providing 12Mm Cement Plaster (1:3) With Clean Coarse Sand Of F.M. 1.5 Including Screening, Curingwithall Leadsand Liftsof Water, Scaffolding Taxes And Royalty All Complete As Per Building Specification And Direction Of E/L. , Providing And Laying 6Mm. Thick Rough Grit Cheqer Tiles In Exterior Walls Of Approved Texture And Colour With 4Mm Down Marble Chips Of Approved Shade, Size And Quality With 100% Ordinary Cement Over 12Mm. Thick Cement Plaster (1:3) Base, Cost Of Panels And Finished With Grit Wash And Rubbed To Give Granolithic Finish Including Cost Of Curing, Scaffolding, Finishing, Royalty And Taxes All Complete As Per Specification And Direction Of E/L. , Providing And Laying 25Mm Thick Granite Tiles In Risers Of Steps, Skirting And Pillars Of Approved Size, Texture And Colour Laid Over 12Mm Thick Cement Mortar (1:3) And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab Including Rubbing To Granolithic Finish With Approved Quality Of Carborandum Stone Including Cost Of Curing, Taxes And Royalty All Complete As Per Building Specification And Direction Of E/I. , Providing And Laying 6Mm Precast White Glazed Tiles In Walls Over 12Mm Cement Mortar (1:3) And Jointed With Grey Cement Slurry Flush Pointed With White Cement Including Rubbing, Polishing And Cost Of Curing, Taxes And Royalty All Complete As Per Building Specification And Direction Of E/L. , Carriage Of Materials Sand Lead From 20 Km , Cement Lead From 20 Km , Stone Chips Lead From 20 Km , Tor Rod Lead From 20 Km , Earth Work In Excavation In Foundation Trenchesin Hard Soil (Vide Classification Of Soil Item B) And Disposal Of Excavated Earth As Obtained To A Distance Up To 50M Including All Lifts, Leveling, Ramming The Foundation Trenches, Removing Roots Of Trees, Shrubs All Complete As Per Approved Design As Per Building Specification And Direction Of E/I. , Providing Coarse Clean Sand In Filling In Foundation Trenches Or In Lintin Including Ramming And Watering In Layers Not Exceeding 150Mm Thicks With All Leads And Lifts Including Cost Of All Materials, Labours Royalty And Taxes All Complete As Per Building Specification And Direction Of E/I. , Providing Designation 75Aone Brick Flat Soiling Joints Filled With Local Sand Including Cost Of Watering Taxes Royalty All Complete As Per Building Specification And Direction Of E/I. , Providing Pcc M-100 With Nominal Mix Of (1:3:6) In Foundation With Approved Quality Of Stone Chips 50Mm To 25Mm Size Graded And Clean Coarse Sand Of F.M. 2.5 To 3 Including Screening, Shuttering, Mixing Cement Concrete In Mixer And Placing In Position, Vibrating, Striking, Curing, Taxes And Royalty All Complete As Per Building Specification And Direction Of E/I. , Providing 250Mm Thick Brick Jail Work In C.M. (1:8) In Foundation With Designation 75A Bricks And Approved Quality Of Clean Coarse Sand Finished With Deep Ruled Pointing In C.M. (1:3) All Complete Jobs As Per Building Specification And Direction Of E/I. , Providing Designation 75A Brick Work In Cement Mortar (1:6) In Foundation And Lintin With Approvedquality Of Clean Coarse Sand F.M. 2 To 2.5Including Providing 10Mm Thick Mortar Joints, Cost Of Screening Materials, Racking Out Joints To 15Mm Depth Curing Taxes And Royalty All Complete As Per Building Specification And Direction Of E/I. , Providing Following Materials As Filter Media In The Pit Of Approved Quality And Size In Layers As Per Drawing And Direction Of Engineer In Charge All Complete Job With All Taxes And Royalty. A) Stone Materials (Confirming To M.O.S.T. Table No.- 400-7) Grade Ii (63-45Mm) , B) Stone Materials (Confirming To M.O.S.T. Table No.- 400-7 Grade Iv , C) Stone Materials (Confirming To M.O.S.T. Table No.- 400-7) Doarse Sand (F.M Greater Than 2) , Providing Precast R.C.C. M-150 With Nominal Mix Of (1:2:4) In Different Place With Approved Quality Of Stone Chips 20Mm To 6Mm Size Graded & Clean Coarse Sand Of Fm 2.5 To 3 Including Screening, Shuttering, Mixing Cement Concrete In Mixer & Placing In Position Vibration, Striking, Curing (But Excluding The Cost Of Reinforcement), Taxes And Royalty All Complete As Per Building Specification And Direction Of E/I. , Providing For Reinforcement As Per Approved Design And Drawing Including Carriage Of Tor Rodto Work Site Including Cutting, Bending And Binding With Anncaled Wire With Cost Of Wire Removal Of Rust Placing The Rodsin Position All Complete As Per Specification And Direction Of E/I. , Providing Fitting And Fixing Suitable M.S. Grating At Inlet Of Soak Pit And Cleaning Of Site For Execution Of Work As Per Direction Of E/I. , Supplying Materials And Construction Of Brick Masonry Drain 150Mm Width And 150Mm Depth With 250Mm Apron On Both Sides Over 50Mm Thick P.C.C (1:3:6) Over A Brick Flat Soling, Apron Laying, Brick Work In C.M (1:6), 12Mm C.P (1:3) With Punning On Exposed Surface All Complete As Per Specification And Direction Of E/I. , Supplying Materials, Labours And Equipments For Construction Of 1.20M X0.90M Size P.C.C (1:2:4) Rectangular Platform Around Stand Post Including 12Mm Thick Cement Plaster In C.M (1:4) With Neat Cement Punning Over Exposed Surface All Complete Job As Per Approved Design, Specification And Direction Of E/I. , Carriage Of Materials Sand Lead From 20 Km , Cement Lead From 20 Km , Brick Lead From 20 Km , Stone Chips Lead From 20 Km , Tor Rod Lead From 20 Km , 18% Gst , Labour Cess
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
35.
Drinking Water Supply and Sanitation #9041146 Technical Bid
Construction For Drinking Water Facility In School Through Hydt With Motor Submersible Pump Set. Under Drinking Water Sanitation Division No 2 Giridih On Turn Key Basis Block Birni Group No Gir-School-2 , Costofdrilling200 Mm X 165 Mm X 150Mtr M Deep Bore Well In All Kinds Of Soil And Rock In Rural Areas For Installation Of Pump Set With Hydraulic Dth Rig Machine, All Complete Including Supplying All Material Tools Drilling Rig And Air Compressor And Equipments As Well As Fuel Lubricants And Cost Of Transportation Of Rig Machine And Other Vehicles Up To Site Including Cost Of Flushing Charges, Geological Investigation Etc. All Complete As Per Direction Of E/I. 0.00 To 50.00 M , Depth 51.00M - 150.00M , Supplying All Tools, Tackles & Lowering Of 200Mm Dia Ms Casing Pipe Including Cost Of Pipe Etc. Including All Taxes, Vat, Excise Duty, Freight Charges With Inspection Charges Etc. As Aplicable,All Complete Including Carriage To Work Site. , Supplying All Materials Labours, Tools & Equipments For Fitting & Fixing 200Mm Dia M.S. Cap Over Casing Pipe Etc. , Civil Portion Supplying All Tools, Equipments And Labours And Lowering 32Mm Dia G.I. Suspension Pipes In 3 Mtrs. Length In The Drilling Bore Of The Tube Well Etc. All Complete Job As Per Direction Of E/I. , Providing Lobours And Equipments Forfitting And Fixing The Deep Well Cylinderassembly With Necessary Connecting Rods Including Jointing Materials Nitrile Rubber Bucket All Tools And Plants Etc Required For The Job For Low Water Level All Comepete Job As Per Specification And Direction Of E/I. , Providing All Labours & Equipments For Fitting Fixing Of Deep Well Hand Pump India Mark-Ii Including Supplying All Tools And Plant Required For The All Job Complete As Per Specification And Direction Of E/I. , Supplying All Materials Including Cement Of Approved Quality, Labours Tools For Constricting 1.85 M Dia. Circular P.C.C. (1:2:4) Platformincluding 12 Mm Thick Cementplaster The Exposed Surface (1:4) With Neat Cement Punningincluding Providing Necessary Shuttering Curing And Carriage Of Materials To Different Tube Well Sites Etc As Per Unicef Design And Direction Of E/I. , Supplying All Materials Labours And Equpments For Constructing Pcc(1:2:4)Drain As Per Unicef Design Etc All Complete , Cost Of Materials Supplying Extra Deep Well Hand Pump Complete Sets With Cylinder Assembly& Connecting Rod (12 Pcs) As Per Is : 15500 Part-2/ 2004(Basic Rate) . , Cost Of 32Mm Dia G.I. Pipe 3 M. Long Screwed At Both Ends With Seamless Socket As Per Is: 1239Including All Taxes Royalty And Contractor Profit Etc , Reducer Cap For Instatlation Of Hand Pump , Supplying All Materials Tools & Labours For Fitting & Fixing Control Pannel Board, 1No. Star Dealta Air Beak Selector Fully Automatic With Build In Single Phase Prevendor1 No. 3 Phase M.C.C. B Suitable With Suitable Size Of Copper Wire And Connectors Etc. , Supplying & Commissiong Of 5 K.V.A Staiblizer (Range 90 V-300V) Three Phase With Cable, Chnge Over Switch For Submersible Pump Etc. All Comp. As Per Specification And Direction Of E/I. , E/W In Exavation (As Per I.S 3114/1965) For Laying Of 32Mm Dia G.I Pipes So As 1.0 M Av. Cover The Socket Of Pipe ………….. Do ……. Etc All Comp. As Per S/D Of E/I. , E/W In Back Filling In Trenches After Laying Different Type & Size Of Pipe With Eath Remove During Excavation Within Initial Lead & Lift As Per Dirction Of E/I. , Supplying All Tools, Labour, Euipment For Supplying Fitting & Fixingsubmersible Pump Set 1.50 H.P Single Phase With Statrer And Pannel Board According To I.S.I Mark Etc All Comp. Job. 150Mm Dia Bonze Impellar , Providing Fitting & Fixing 3 Core 2.5 Sqm Flate Copper Cable For Submersible Motor Pump. , Providing & Fixing 20Mm Nylon Rope For Hoisting Thesubmersible Motor Pump In Bore Well. , Supplying Upvc Pipe Approved I.S.I Make Etc As Per S/D Of E/I. (For Column Pipe) (A)32Mm Dia Column Pipe 65M , Supplying All Materials ,Labours And Laying G.I. Medium Pipesofapproved Make In Trenches With Red Lead And Yarn With G.I. Socket And Screw Joints And Cutting Pipes To Sizes And Threading Ends Where Necessary Etc. All Complete As Per Specification And Direction Of Engineer-In-Charge A) 32Mm Dia , B) 25Mm Dia , Supplying And Fixing G.I. Fitting Of Approved Make All Complete As Per Specification And Direction Of Engineer-In-Charge.(I)32 Mm Gi Elbow , (Ii)32Mmreducing Socket , (Iii)32Mm Union Socket , (V)32Mmtee , (Ii)25Mmreducing Socket , (V)25Mmtee , (Vii)25 Mm Jam Nut , 15Mm Nipple , 15Mm Socket , Providing And Fixing Of Male Ended C.I.Body Brass Spindle Valve And Seat Bib Cock Of Approved Quality With Extra Socketall Complete As Per Specification And Direction Of E/I. , Providing & Fixing Gm Non-Return Valve Of Approved Quality As Per Specification & Direction Of E/I. 32 Mm Dia , Providing And Fixing Gun Metal Full Way Valves Of Approved Make All Complete As Per Specification And Direction Of Engineer-In-Charge 32 Mm Dia G.M. Full Way Valve Weight Not Less Than 1.5 Kg , Providing Polyvinyle Water Storage Tank(1000 X 2 No= 2000) Of I.S.I Mark (Himgiri/Gangotri) Etc With Cover And Locking Arrangement System Etc. All Comp. Job. , Making Holes In Walls For Laying G.I Pipes And Restoring The Same After Pipe Laying As Per Specification And Direction Of E./I 125Mm Thick , Providing Fitting & Fixing 2 Core 2.5 Sqm Copper Cable Forelectric Connection. , Supplying All Materials Tools Labours And Laying Ofgi Pipe Tata Or Equivalent 32 Mm Dia (In Trench ) , 15 Mm Dia (On Wall) , Supplyingfitting & Fixing.Gifittings Fullway Valve 32Mm , Union Socket 32Mm , Gi Elbow 32Mm , Gi Elbow 15Mm , Gi Tee 32Mm , Gi Tee 15Mm , R/Socket 32Mm , Socket 32Mm , Socket 15Mm , Nipple 15Mm , Earth Work In Excavation In Foundation Trenchesin Hard Soil (Vide Classification Of Soil Item B) And Disposal Of Excavated Earth As Obtained To A Distance Up To 50M Including All Lifts, Leveling, Ramming The Foundation Trenches, Removing Roots Of Trees, Shrubs All Complete As Per Approved Design As Per Building Specification And Direction Of E/I. , Providing Coarse Clean Sand In Filling In Foundation Trenches Or In Lintin Including Ramming And Watering In Layers Not Exceeding 150Mm Thicks With All Leads And Lifts Including Cost Of All Materials, Labours Royalty And Taxes All Complete As Per Building Specification And Direction Of E/I. , Providing Designation 75Aone Brick Flat Soiling Joints Filled With Local Sand Including Cost Of Watering Taxes Royalty All Complete As Per Building Specification And Direction Of E/I. , Providing R.C.C.M - 200 With Nominal Mix Of (1:1.5:3) In Foundation And Plinth With Approved Quality Of Stone Chips 20 Mm To 6 Mm Size Graded And Clean Coarse Sand Of F.M. 2.5 To 3 Including Screening, Shuttering, Mixing Cement Concrete In Mixer And Placing In Position, Vibrating, Striking, Curing (But Excluding The Cost Of Reinforcement) Taxes And Royalty All Complete As Per Building Specification And Direction Of E/L. , Providing R.C.C.M- 200 With Nominal Mix (1:1.5:3) In Columns With Approved Quality Of Stone Chips 20Mm To 6Mm Size Graded And Clean Coarse Sand Of F.M.2.5 To 3 Including, Screening Shuttering Mixing Cement Concrete In Mixer And Placing In Position Vibrating, Striking, Curing Taxes Androyalty All Complete As Per Building Specification And Direction Of E/I , Providing R.C.C.M- 200 With Nominal Mix (1:1:5:3) In Roof Slab With Approved Quality Of Stone Chips 20Mm To 6Mm Size Graded And Clean Coarse Sand Of F.M.2.5 To 3 Including, Screening Shuttering Mixing Cement Concrete In Mixer And Placing In Position Vibrating, Striking, Curing Taxes Androyalty All Complete As Per Building Specification And Direction Of E/I , Dismantling Old Plaster And Pointing In Cement Or Lime And Raking Out Joints To 15 Mm. Depth, Watering And Disposal Of Unserviceable Materials With All Leads All Complete As Per Direction Of E/L , Providing 12Mm Cement Plaster (1:3) With Clean Coarse Sand Of F.M. 1.5 Including Screening, Curingwithall Leadsand Liftsof Water, Scaffolding Taxes And Royalty All Complete As Per Building Specification And Direction Of E/L. , Providing And Laying 6Mm. Thick Rough Grit Cheqer Tiles In Exterior Walls Of Approved Texture And Colour With 4Mm Down Marble Chips Of Approved Shade, Size And Quality With 100% Ordinary Cement Over 12Mm. Thick Cement Plaster (1:3) Base, Cost Of Panels And Finished With Grit Wash And Rubbed To Give Granolithic Finish Including Cost Of Curing, Scaffolding, Finishing, Royalty And Taxes All Complete As Per Specification And Direction Of E/L. , Providing And Laying 25Mm Thick Granite Tiles In Risers Of Steps, Skirting And Pillars Of Approved Size, Texture And Colour Laid Over 12Mm Thick Cement Mortar (1:3) And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab Including Rubbing To Granolithic Finish With Approved Quality Of Carborandum Stone Including Cost Of Curing, Taxes And Royalty All Complete As Per Building Specification And Direction Of E/I. , Providing And Laying 6Mm Precast White Glazed Tiles In Walls Over 12Mm Cement Mortar (1:3) And Jointed With Grey Cement Slurry Flush Pointed With White Cement Including Rubbing, Polishing And Cost Of Curing, Taxes And Royalty All Complete As Per Building Specification And Direction Of E/L. , Carriage Of Materials Sand Lead From 20 Km , Cement Lead From 20 Km , Stone Chips Lead From 20 Km , Tor Rod Lead From 20 Km , Earth Work In Excavation In Foundation Trenchesin Hard Soil (Vide Classification Of Soil Item B) And Disposal Of Excavated Earth As Obtained To A Distance Up To 50M Including All Lifts, Leveling, Ramming The Foundation Trenches, Removing Roots Of Trees, Shrubs All Complete As Per Approved Design As Per Building Specification And Direction Of E/I. , Providing Coarse Clean Sand In Filling In Foundation Trenches Or In Lintin Including Ramming And Watering In Layers Not Exceeding 150Mm Thicks With All Leads And Lifts Including Cost Of All Materials, Labours Royalty And Taxes All Complete As Per Building Specification And Direction Of E/I. , Providing Designation 75Aone Brick Flat Soiling Joints Filled With Local Sand Including Cost Of Watering Taxes Royalty All Complete As Per Building Specification And Direction Of E/I. , Providing Pcc M-100 With Nominal Mix Of (1:3:6) In Foundation With Approved Quality Of Stone Chips 50Mm To 25Mm Size Graded And Clean Coarse Sand Of F.M. 2.5 To 3 Including Screening, Shuttering, Mixing Cement Concrete In Mixer And Placing In Position, Vibrating, Striking, Curing, Taxes And Royalty All Complete As Per Building Specification And Direction Of E/I. , Providing 250Mm Thick Brick Jail Work In C.M. (1:8) In Foundation With Designation 75A Bricks And Approved Quality Of Clean Coarse Sand Finished With Deep Ruled Pointing In C.M. (1:3) All Complete Jobs As Per Building Specification And Direction Of E/I. , Providing Designation 75A Brick Work In Cement Mortar (1:6) In Foundation And Lintin With Approvedquality Of Clean Coarse Sand F.M. 2 To 2.5Including Providing 10Mm Thick Mortar Joints, Cost Of Screening Materials, Racking Out Joints To 15Mm Depth Curing Taxes And Royalty All Complete As Per Building Specification And Direction Of E/I. , Providing Following Materials As Filter Media In The Pit Of Approved Quality And Size In Layers As Per Drawing And Direction Of Engineer In Charge All Complete Job With All Taxes And Royalty. A) Stone Materials (Confirming To M.O.S.T. Table No.- 400-7) Grade Ii (63-45Mm) , B) Stone Materials (Confirming To M.O.S.T. Table No.- 400-7 Grade Iv , C) Stone Materials (Confirming To M.O.S.T. Table No.- 400-7) Doarse Sand (F.M Greater Than 2) , Providing Precast R.C.C. M-150 With Nominal Mix Of (1:2:4) In Different Place With Approved Quality Of Stone Chips 20Mm To 6Mm Size Graded & Clean Coarse Sand Of Fm 2.5 To 3 Including Screening, Shuttering, Mixing Cement Concrete In Mixer & Placing In Position Vibration, Striking, Curing (But Excluding The Cost Of Reinforcement), Taxes And Royalty All Complete As Per Building Specification And Direction Of E/I. , Providing For Reinforcement As Per Approved Design And Drawing Including Carriage Of Tor Rodto Work Site Including Cutting, Bending And Binding With Anncaled Wire With Cost Of Wire Removal Of Rust Placing The Rodsin Position All Complete As Per Specification And Direction Of E/I. , Providing Fitting And Fixing Suitable M.S. Grating At Inlet Of Soak Pit And Cleaning Of Site For Execution Of Work As Per Direction Of E/I. , Supplying Materials And Construction Of Brick Masonry Drain 150Mm Width And 150Mm Depth With 250Mm Apron On Both Sides Over 50Mm Thick P.C.C (1:3:6) Over A Brick Flat Soling, Apron Laying, Brick Work In C.M (1:6), 12Mm C.P (1:3) With Punning On Exposed Surface All Complete As Per Specification And Direction Of E/I. , Supplying Materials, Labours And Equipments For Construction Of 1.20M X0.90M Size P.C.C (1:2:4) Rectangular Platform Around Stand Post Including 12Mm Thick Cement Plaster In C.M (1:4) With Neat Cement Punning Over Exposed Surface All Complete Job As Per Approved Design, Specification And Direction Of E/I. , Carriage Of Materials Sand Lead From 20 Km , Cement Lead From 20 Km , Brick Lead From 20 Km , Stone Chips Lead From 20 Km , Tor Rod Lead From 20 Km , 18% Gst , Labour Cess
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
36.
Drinking Water Supply and Sanitation #9041137 Technical Bid
Construction For Drinking Water Facility In School Through Hydt With Motor Submersible Pump Set. Under Drinking Water Sanitation Division No 2 Giridih On Turn Key Basis Block Gawan Group No Gir-School-4 , Costofdrilling200 Mm X 165 Mm X 150Mtr M Deep Bore Well In All Kinds Of Soil And Rock In Rural Areas For Installation Of Pump Set With Hydraulic Dth Rig Machine, All Complete Including Supplying All Material Tools Drilling Rig And Air Compressor And Equipments As Well As Fuel Lubricants And Cost Of Transportation Of Rig Machine And Other Vehicles Up To Site Including Cost Of Flushing Charges, Geological Investigation Etc. All Complete As Per Direction Of E/I. 0.00 To 50.00 M , Depth 51.00M - 150.00M , Supplying All Tools, Tackles & Lowering Of 200Mm Dia Ms Casing Pipe Including Cost Of Pipe Etc. Including All Taxes, Vat, Excise Duty, Freight Charges With Inspection Charges Etc. As Aplicable,All Complete Including Carriage To Work Site. , Supplying All Materials Labours, Tools & Equipments For Fitting & Fixing 200Mm Dia M.S. Cap Over Casing Pipe Etc. , Civil Portion Supplying All Tools, Equipments And Labours And Lowering 32Mm Dia G.I. Suspension Pipes In 3 Mtrs. Length In The Drilling Bore Of The Tube Well Etc. All Complete Job As Per Direction Of E/I. , Providing Lobours And Equipments Forfitting And Fixing The Deep Well Cylinderassembly With Necessary Connecting Rods Including Jointing Materials Nitrile Rubber Bucket All Tools And Plants Etc Required For The Job For Low Water Level All Comepete Job As Per Specification And Direction Of E/I. , Providing All Labours & Equipments For Fitting Fixing Of Deep Well Hand Pump India Mark-Ii Including Supplying All Tools And Plant Required For The All Job Complete As Per Specification And Direction Of E/I. , Supplying All Materials Including Cement Of Approved Quality, Labours Tools For Constricting 1.85 M Dia. Circular P.C.C. (1:2:4) Platformincluding 12 Mm Thick Cementplaster The Exposed Surface (1:4) With Neat Cement Punningincluding Providing Necessary Shuttering Curing And Carriage Of Materials To Different Tube Well Sites Etc As Per Unicef Design And Direction Of E/I. , Supplying All Materials Labours And Equpments For Constructing Pcc(1:2:4)Drain As Per Unicef Design Etc All Complete , Cost Of Materials Supplying Extra Deep Well Hand Pump Complete Sets With Cylinder Assembly& Connecting Rod (12 Pcs) As Per Is : 15500 Part-2/ 2004(Basic Rate) . , Cost Of 32Mm Dia G.I. Pipe 3 M. Long Screwed At Both Ends With Seamless Socket As Per Is: 1239Including All Taxes Royalty And Contractor Profit Etc , Reducer Cap For Instatlation Of Hand Pump , Supplying All Materials Tools & Labours For Fitting & Fixing Control Pannel Board, 1No. Star Dealta Air Beak Selector Fully Automatic With Build In Single Phase Prevendor1 No. 3 Phase M.C.C. B Suitable With Suitable Size Of Copper Wire And Connectors Etc. , Supplying & Commissiong Of 5 K.V.A Staiblizer (Range 90 V-300V) Three Phase With Cable, Chnge Over Switch For Submersible Pump Etc. All Comp. As Per Specification And Direction Of E/I. , E/W In Exavation (As Per I.S 3114/1965) For Laying Of 32Mm Dia G.I Pipes So As 1.0 M Av. Cover The Socket Of Pipe ………….. Do ……. Etc All Comp. As Per S/D Of E/I. , E/W In Back Filling In Trenches After Laying Different Type & Size Of Pipe With Eath Remove During Excavation Within Initial Lead & Lift As Per Dirction Of E/I. , Supplying All Tools, Labour, Euipment For Supplying Fitting & Fixingsubmersible Pump Set 1.50 H.P Single Phase With Statrer And Pannel Board According To I.S.I Mark Etc All Comp. Job. 150Mm Dia Bonze Impellar , Providing Fitting & Fixing 3 Core 2.5 Sqm Flate Copper Cable For Submersible Motor Pump. , Providing & Fixing 20Mm Nylon Rope For Hoisting Thesubmersible Motor Pump In Bore Well. , Supplying Upvc Pipe Approved I.S.I Make Etc As Per S/D Of E/I. (For Column Pipe) (A)32Mm Dia Column Pipe 65M , Supplying All Materials ,Labours And Laying G.I. Medium Pipesofapproved Make In Trenches With Red Lead And Yarn With G.I. Socket And Screw Joints And Cutting Pipes To Sizes And Threading Ends Where Necessary Etc. All Complete As Per Specification And Direction Of Engineer-In-Charge A) 32Mm Dia , B) 25Mm Dia , Supplying And Fixing G.I. Fitting Of Approved Make All Complete As Per Specification And Direction Of Engineer-In-Charge.(I)32 Mm Gi Elbow , (Ii)32Mmreducing Socket , (Iii)32Mm Union Socket , (V)32Mmtee , (Ii)25Mmreducing Socket , (V)25Mmtee , (Vii)25 Mm Jam Nut , 15Mm Nipple , 15Mm Socket , Providing And Fixing Of Male Ended C.I.Body Brass Spindle Valve And Seat Bib Cock Of Approved Quality With Extra Socketall Complete As Per Specification And Direction Of E/I. , Providing & Fixing Gm Non-Return Valve Of Approved Quality As Per Specification & Direction Of E/I. 32 Mm Dia , Providing And Fixing Gun Metal Full Way Valves Of Approved Make All Complete As Per Specification And Direction Of Engineer-In-Charge 32 Mm Dia G.M. Full Way Valve Weight Not Less Than 1.5 Kg , Providing Polyvinyle Water Storage Tank(1000 X 2 No= 2000) Of I.S.I Mark (Himgiri/Gangotri) Etc With Cover And Locking Arrangement System Etc. All Comp. Job. , Making Holes In Walls For Laying G.I Pipes And Restoring The Same After Pipe Laying As Per Specification And Direction Of E./I 125Mm Thick , Providing Fitting & Fixing 2 Core 2.5 Sqm Copper Cable Forelectric Connection. , Supplying All Materials Tools Labours And Laying Ofgi Pipe Tata Or Equivalent 32 Mm Dia (In Trench ) , 15 Mm Dia (On Wall) , Supplyingfitting & Fixing.Gifittings Fullway Valve 32Mm , Union Socket 32Mm , Gi Elbow 32Mm , Gi Elbow 15Mm , Gi Tee 32Mm , Gi Tee 15Mm , R/Socket 32Mm , Socket 32Mm , Socket 15Mm , Nipple 15Mm , Earth Work In Excavation In Foundation Trenchesin Hard Soil (Vide Classification Of Soil Item B) And Disposal Of Excavated Earth As Obtained To A Distance Up To 50M Including All Lifts, Leveling, Ramming The Foundation Trenches, Removing Roots Of Trees, Shrubs All Complete As Per Approved Design As Per Building Specification And Direction Of E/I. , Providing Coarse Clean Sand In Filling In Foundation Trenches Or In Lintin Including Ramming And Watering In Layers Not Exceeding 150Mm Thicks With All Leads And Lifts Including Cost Of All Materials, Labours Royalty And Taxes All Complete As Per Building Specification And Direction Of E/I. , Providing Designation 75Aone Brick Flat Soiling Joints Filled With Local Sand Including Cost Of Watering Taxes Royalty All Complete As Per Building Specification And Direction Of E/I. , Providing R.C.C.M - 200 With Nominal Mix Of (1:1.5:3) In Foundation And Plinth With Approved Quality Of Stone Chips 20 Mm To 6 Mm Size Graded And Clean Coarse Sand Of F.M. 2.5 To 3 Including Screening, Shuttering, Mixing Cement Concrete In Mixer And Placing In Position, Vibrating, Striking, Curing (But Excluding The Cost Of Reinforcement) Taxes And Royalty All Complete As Per Building Specification And Direction Of E/L. , Providing R.C.C.M- 200 With Nominal Mix (1:1.5:3) In Columns With Approved Quality Of Stone Chips 20Mm To 6Mm Size Graded And Clean Coarse Sand Of F.M.2.5 To 3 Including, Screening Shuttering Mixing Cement Concrete In Mixer And Placing In Position Vibrating, Striking, Curing Taxes Androyalty All Complete As Per Building Specification And Direction Of E/I , Providing R.C.C.M- 200 With Nominal Mix (1:1:5:3) In Roof Slab With Approved Quality Of Stone Chips 20Mm To 6Mm Size Graded And Clean Coarse Sand Of F.M.2.5 To 3 Including, Screening Shuttering Mixing Cement Concrete In Mixer And Placing In Position Vibrating, Striking, Curing Taxes Androyalty All Complete As Per Building Specification And Direction Of E/I , Dismantling Old Plaster And Pointing In Cement Or Lime And Raking Out Joints To 15 Mm. Depth, Watering And Disposal Of Unserviceable Materials With All Leads All Complete As Per Direction Of E/L , Providing 12Mm Cement Plaster (1:3) With Clean Coarse Sand Of F.M. 1.5 Including Screening, Curingwithall Leadsand Liftsof Water, Scaffolding Taxes And Royalty All Complete As Per Building Specification And Direction Of E/L. , Providing And Laying 6Mm. Thick Rough Grit Cheqer Tiles In Exterior Walls Of Approved Texture And Colour With 4Mm Down Marble Chips Of Approved Shade, Size And Quality With 100% Ordinary Cement Over 12Mm. Thick Cement Plaster (1:3) Base, Cost Of Panels And Finished With Grit Wash And Rubbed To Give Granolithic Finish Including Cost Of Curing, Scaffolding, Finishing, Royalty And Taxes All Complete As Per Specification And Direction Of E/L. , Providing And Laying 25Mm Thick Granite Tiles In Risers Of Steps, Skirting And Pillars Of Approved Size, Texture And Colour Laid Over 12Mm Thick Cement Mortar (1:3) And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab Including Rubbing To Granolithic Finish With Approved Quality Of Carborandum Stone Including Cost Of Curing, Taxes And Royalty All Complete As Per Building Specification And Direction Of E/I. , Providing And Laying 6Mm Precast White Glazed Tiles In Walls Over 12Mm Cement Mortar (1:3) And Jointed With Grey Cement Slurry Flush Pointed With White Cement Including Rubbing, Polishing And Cost Of Curing, Taxes And Royalty All Complete As Per Building Specification And Direction Of E/L. , Carriage Of Materials Sand Lead From 20 Km , Cement Lead From 20 Km , Stone Chips Lead From 20 Km , Tor Rod Lead From 20 Km , Earth Work In Excavation In Foundation Trenchesin Hard Soil (Vide Classification Of Soil Item B) And Disposal Of Excavated Earth As Obtained To A Distance Up To 50M Including All Lifts, Leveling, Ramming The Foundation Trenches, Removing Roots Of Trees, Shrubs All Complete As Per Approved Design As Per Building Specification And Direction Of E/I. , Providing Coarse Clean Sand In Filling In Foundation Trenches Or In Lintin Including Ramming And Watering In Layers Not Exceeding 150Mm Thicks With All Leads And Lifts Including Cost Of All Materials, Labours Royalty And Taxes All Complete As Per Building Specification And Direction Of E/I. , Providing Designation 75Aone Brick Flat Soiling Joints Filled With Local Sand Including Cost Of Watering Taxes Royalty All Complete As Per Building Specification And Direction Of E/I. , Providing Pcc M-100 With Nominal Mix Of (1:3:6) In Foundation With Approved Quality Of Stone Chips 50Mm To 25Mm Size Graded And Clean Coarse Sand Of F.M. 2.5 To 3 Including Screening, Shuttering, Mixing Cement Concrete In Mixer And Placing In Position, Vibrating, Striking, Curing, Taxes And Royalty All Complete As Per Building Specification And Direction Of E/I. , Providing 250Mm Thick Brick Jail Work In C.M. (1:8) In Foundation With Designation 75A Bricks And Approved Quality Of Clean Coarse Sand Finished With Deep Ruled Pointing In C.M. (1:3) All Complete Jobs As Per Building Specification And Direction Of E/I. , Providing Designation 75A Brick Work In Cement Mortar (1:6) In Foundation And Lintin With Approvedquality Of Clean Coarse Sand F.M. 2 To 2.5Including Providing 10Mm Thick Mortar Joints, Cost Of Screening Materials, Racking Out Joints To 15Mm Depth Curing Taxes And Royalty All Complete As Per Building Specification And Direction Of E/I. , Providing Following Materials As Filter Media In The Pit Of Approved Quality And Size In Layers As Per Drawing And Direction Of Engineer In Charge All Complete Job With All Taxes And Royalty. A) Stone Materials (Confirming To M.O.S.T. Table No.- 400-7) Grade Ii (63-45Mm) , B) Stone Materials (Confirming To M.O.S.T. Table No.- 400-7 Grade Iv , C) Stone Materials (Confirming To M.O.S.T. Table No.- 400-7) Doarse Sand (F.M Greater Than 2) , Providing Precast R.C.C. M-150 With Nominal Mix Of (1:2:4) In Different Place With Approved Quality Of Stone Chips 20Mm To 6Mm Size Graded & Clean Coarse Sand Of Fm 2.5 To 3 Including Screening, Shuttering, Mixing Cement Concrete In Mixer & Placing In Position Vibration, Striking, Curing (But Excluding The Cost Of Reinforcement), Taxes And Royalty All Complete As Per Building Specification And Direction Of E/I. , Providing For Reinforcement As Per Approved Design And Drawing Including Carriage Of Tor Rodto Work Site Including Cutting, Bending And Binding With Anncaled Wire With Cost Of Wire Removal Of Rust Placing The Rodsin Position All Complete As Per Specification And Direction Of E/I. , Providing Fitting And Fixing Suitable M.S. Grating At Inlet Of Soak Pit And Cleaning Of Site For Execution Of Work As Per Direction Of E/I. , Supplying Materials And Construction Of Brick Masonry Drain 150Mm Width And 150Mm Depth With 250Mm Apron On Both Sides Over 50Mm Thick P.C.C (1:3:6) Over A Brick Flat Soling, Apron Laying, Brick Work In C.M (1:6), 12Mm C.P (1:3) With Punning On Exposed Surface All Complete As Per Specification And Direction Of E/I. , Supplying Materials, Labours And Equipments For Construction Of 1.20M X0.90M Size P.C.C (1:2:4) Rectangular Platform Around Stand Post Including 12Mm Thick Cement Plaster In C.M (1:4) With Neat Cement Punning Over Exposed Surface All Complete Job As Per Approved Design, Specification And Direction Of E/I. , Carriage Of Materials Sand Lead From 20 Km , Cement Lead From 20 Km , Brick Lead From 20 Km , Stone Chips Lead From 20 Km , Tor Rod Lead From 20 Km , 18% Gst , Labour Cess
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
37.
Drinking Water Supply and Sanitation #9041132 Technical Bid
Construction For Drinking Water Facility In School Through Hydt With Motor Submersible Pump Set. Under Drinking Water Sanitation Division No 2 Giridih On Turn Key Basis Block Pirtand Group No Gir-School-5 , Costofdrilling200 Mm X 165 Mm X 150Mtr M Deep Bore Well In All Kinds Of Soil And Rock In Rural Areas For Installation Of Pump Set With Hydraulic Dth Rig Machine, All Complete Including Supplying All Material Tools Drilling Rig And Air Compressor And Equipments As Well As Fuel Lubricants And Cost Of Transportation Of Rig Machine And Other Vehicles Up To Site Including Cost Of Flushing Charges, Geological Investigation Etc. All Complete As Per Direction Of E/I. 0.00 To 50.00 M , Depth 51.00M - 150.00M , Supplying All Tools, Tackles & Lowering Of 200Mm Dia Ms Casing Pipe Including Cost Of Pipe Etc. Including All Taxes, Vat, Excise Duty, Freight Charges With Inspection Charges Etc. As Aplicable,All Complete Including Carriage To Work Site. , Supplying All Materials Labours, Tools & Equipments For Fitting & Fixing 200Mm Dia M.S. Cap Over Casing Pipe Etc. , Civil Portion Supplying All Tools, Equipments And Labours And Lowering 32Mm Dia G.I. Suspension Pipes In 3 Mtrs. Length In The Drilling Bore Of The Tube Well Etc. All Complete Job As Per Direction Of E/I. , Providing Lobours And Equipments Forfitting And Fixing The Deep Well Cylinderassembly With Necessary Connecting Rods Including Jointing Materials Nitrile Rubber Bucket All Tools And Plants Etc Required For The Job For Low Water Level All Comepete Job As Per Specification And Direction Of E/I. , Providing All Labours & Equipments For Fitting Fixing Of Deep Well Hand Pump India Mark-Ii Including Supplying All Tools And Plant Required For The All Job Complete As Per Specification And Direction Of E/I. , Supplying All Materials Including Cement Of Approved Quality, Labours Tools For Constricting 1.85 M Dia. Circular P.C.C. (1:2:4) Platformincluding 12 Mm Thick Cementplaster The Exposed Surface (1:4) With Neat Cement Punningincluding Providing Necessary Shuttering Curing And Carriage Of Materials To Different Tube Well Sites Etc As Per Unicef Design And Direction Of E/I. , Supplying All Materials Labours And Equpments For Constructing Pcc(1:2:4)Drain As Per Unicef Design Etc All Complete , Cost Of Materials Supplying Extra Deep Well Hand Pump Complete Sets With Cylinder Assembly& Connecting Rod (12 Pcs) As Per Is : 15500 Part-2/ 2004(Basic Rate) . , Cost Of 32Mm Dia G.I. Pipe 3 M. Long Screwed At Both Ends With Seamless Socket As Per Is: 1239Including All Taxes Royalty And Contractor Profit Etc , Reducer Cap For Instatlation Of Hand Pump , Supplying All Materials Tools & Labours For Fitting & Fixing Control Pannel Board, 1No. Star Dealta Air Beak Selector Fully Automatic With Build In Single Phase Prevendor1 No. 3 Phase M.C.C. B Suitable With Suitable Size Of Copper Wire And Connectors Etc. , Supplying & Commissiong Of 5 K.V.A Staiblizer (Range 90 V-300V) Three Phase With Cable, Chnge Over Switch For Submersible Pump Etc. All Comp. As Per Specification And Direction Of E/I. , E/W In Exavation (As Per I.S 3114/1965) For Laying Of 32Mm Dia G.I Pipes So As 1.0 M Av. Cover The Socket Of Pipe ………….. Do ……. Etc All Comp. As Per S/D Of E/I. , E/W In Back Filling In Trenches After Laying Different Type & Size Of Pipe With Eath Remove During Excavation Within Initial Lead & Lift As Per Dirction Of E/I. , Supplying All Tools, Labour, Euipment For Supplying Fitting & Fixingsubmersible Pump Set 1.50 H.P Single Phase With Statrer And Pannel Board According To I.S.I Mark Etc All Comp. Job. 150Mm Dia Bonze Impellar , Providing Fitting & Fixing 3 Core 2.5 Sqm Flate Copper Cable For Submersible Motor Pump. , Providing & Fixing 20Mm Nylon Rope For Hoisting Thesubmersible Motor Pump In Bore Well. , Supplying Upvc Pipe Approved I.S.I Make Etc As Per S/D Of E/I. (For Column Pipe) (A)32Mm Dia Column Pipe 65M , Supplying All Materials ,Labours And Laying G.I. Medium Pipesofapproved Make In Trenches With Red Lead And Yarn With G.I. Socket And Screw Joints And Cutting Pipes To Sizes And Threading Ends Where Necessary Etc. All Complete As Per Specification And Direction Of Engineer-In-Charge A) 32Mm Dia , B) 25Mm Dia , Supplying And Fixing G.I. Fitting Of Approved Make All Complete As Per Specification And Direction Of Engineer-In-Charge.(I)32 Mm Gi Elbow , (Ii)32Mmreducing Socket , (Iii)32Mm Union Socket , (V)32Mmtee , (Ii)25Mmreducing Socket , (V)25Mmtee , (Vii)25 Mm Jam Nut , 15Mm Nipple , 15Mm Socket , Providing And Fixing Of Male Ended C.I.Body Brass Spindle Valve And Seat Bib Cock Of Approved Quality With Extra Socketall Complete As Per Specification And Direction Of E/I. , Providing & Fixing Gm Non-Return Valve Of Approved Quality As Per Specification & Direction Of E/I. 32 Mm Dia , Providing And Fixing Gun Metal Full Way Valves Of Approved Make All Complete As Per Specification And Direction Of Engineer-In-Charge 32 Mm Dia G.M. Full Way Valve Weight Not Less Than 1.5 Kg , Providing Polyvinyle Water Storage Tank(1000 X 2 No= 2000) Of I.S.I Mark (Himgiri/Gangotri) Etc With Cover And Locking Arrangement System Etc. All Comp. Job. , Making Holes In Walls For Laying G.I Pipes And Restoring The Same After Pipe Laying As Per Specification And Direction Of E./I 125Mm Thick , Providing Fitting & Fixing 2 Core 2.5 Sqm Copper Cable Forelectric Connection. , Supplying All Materials Tools Labours And Laying Ofgi Pipe Tata Or Equivalent 32 Mm Dia (In Trench ) , 15 Mm Dia (On Wall) , Supplyingfitting & Fixing.Gifittings Fullway Valve 32Mm , Union Socket 32Mm , Gi Elbow 32Mm , Gi Elbow 15Mm , Gi Tee 32Mm , Gi Tee 15Mm , R/Socket 32Mm , Socket 32Mm , Socket 15Mm , Nipple 15Mm , Earth Work In Excavation In Foundation Trenchesin Hard Soil (Vide Classification Of Soil Item B) And Disposal Of Excavated Earth As Obtained To A Distance Up To 50M Including All Lifts, Leveling, Ramming The Foundation Trenches, Removing Roots Of Trees, Shrubs All Complete As Per Approved Design As Per Building Specification And Direction Of E/I. , Providing Coarse Clean Sand In Filling In Foundation Trenches Or In Lintin Including Ramming And Watering In Layers Not Exceeding 150Mm Thicks With All Leads And Lifts Including Cost Of All Materials, Labours Royalty And Taxes All Complete As Per Building Specification And Direction Of E/I. , Providing Designation 75Aone Brick Flat Soiling Joints Filled With Local Sand Including Cost Of Watering Taxes Royalty All Complete As Per Building Specification And Direction Of E/I. , Providing R.C.C.M - 200 With Nominal Mix Of (1:1.5:3) In Foundation And Plinth With Approved Quality Of Stone Chips 20 Mm To 6 Mm Size Graded And Clean Coarse Sand Of F.M. 2.5 To 3 Including Screening, Shuttering, Mixing Cement Concrete In Mixer And Placing In Position, Vibrating, Striking, Curing (But Excluding The Cost Of Reinforcement) Taxes And Royalty All Complete As Per Building Specification And Direction Of E/L. , Providing R.C.C.M- 200 With Nominal Mix (1:1.5:3) In Columns With Approved Quality Of Stone Chips 20Mm To 6Mm Size Graded And Clean Coarse Sand Of F.M.2.5 To 3 Including, Screening Shuttering Mixing Cement Concrete In Mixer And Placing In Position Vibrating, Striking, Curing Taxes Androyalty All Complete As Per Building Specification And Direction Of E/I , Providing R.C.C.M- 200 With Nominal Mix (1:1:5:3) In Roof Slab With Approved Quality Of Stone Chips 20Mm To 6Mm Size Graded And Clean Coarse Sand Of F.M.2.5 To 3 Including, Screening Shuttering Mixing Cement Concrete In Mixer And Placing In Position Vibrating, Striking, Curing Taxes Androyalty All Complete As Per Building Specification And Direction Of E/I , Dismantling Old Plaster And Pointing In Cement Or Lime And Raking Out Joints To 15 Mm. Depth, Watering And Disposal Of Unserviceable Materials With All Leads All Complete As Per Direction Of E/L , Providing 12Mm Cement Plaster (1:3) With Clean Coarse Sand Of F.M. 1.5 Including Screening, Curingwithall Leadsand Liftsof Water, Scaffolding Taxes And Royalty All Complete As Per Building Specification And Direction Of E/L. , Providing And Laying 6Mm. Thick Rough Grit Cheqer Tiles In Exterior Walls Of Approved Texture And Colour With 4Mm Down Marble Chips Of Approved Shade, Size And Quality With 100% Ordinary Cement Over 12Mm. Thick Cement Plaster (1:3) Base, Cost Of Panels And Finished With Grit Wash And Rubbed To Give Granolithic Finish Including Cost Of Curing, Scaffolding, Finishing, Royalty And Taxes All Complete As Per Specification And Direction Of E/L. , Providing And Laying 25Mm Thick Granite Tiles In Risers Of Steps, Skirting And Pillars Of Approved Size, Texture And Colour Laid Over 12Mm Thick Cement Mortar (1:3) And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab Including Rubbing To Granolithic Finish With Approved Quality Of Carborandum Stone Including Cost Of Curing, Taxes And Royalty All Complete As Per Building Specification And Direction Of E/I. , Providing And Laying 6Mm Precast White Glazed Tiles In Walls Over 12Mm Cement Mortar (1:3) And Jointed With Grey Cement Slurry Flush Pointed With White Cement Including Rubbing, Polishing And Cost Of Curing, Taxes And Royalty All Complete As Per Building Specification And Direction Of E/L. , Carriage Of Materials Sand Lead From 20 Km , Cement Lead From 20 Km , Stone Chips Lead From 20 Km , Tor Rod Lead From 20 Km , Earth Work In Excavation In Foundation Trenchesin Hard Soil (Vide Classification Of Soil Item B) And Disposal Of Excavated Earth As Obtained To A Distance Up To 50M Including All Lifts, Leveling, Ramming The Foundation Trenches, Removing Roots Of Trees, Shrubs All Complete As Per Approved Design As Per Building Specification And Direction Of E/I. , Providing Coarse Clean Sand In Filling In Foundation Trenches Or In Lintin Including Ramming And Watering In Layers Not Exceeding 150Mm Thicks With All Leads And Lifts Including Cost Of All Materials, Labours Royalty And Taxes All Complete As Per Building Specification And Direction Of E/I. , Providing Designation 75Aone Brick Flat Soiling Joints Filled With Local Sand Including Cost Of Watering Taxes Royalty All Complete As Per Building Specification And Direction Of E/I. , Providing Pcc M-100 With Nominal Mix Of (1:3:6) In Foundation With Approved Quality Of Stone Chips 50Mm To 25Mm Size Graded And Clean Coarse Sand Of F.M. 2.5 To 3 Including Screening, Shuttering, Mixing Cement Concrete In Mixer And Placing In Position, Vibrating, Striking, Curing, Taxes And Royalty All Complete As Per Building Specification And Direction Of E/I. , Providing 250Mm Thick Brick Jail Work In C.M. (1:8) In Foundation With Designation 75A Bricks And Approved Quality Of Clean Coarse Sand Finished With Deep Ruled Pointing In C.M. (1:3) All Complete Jobs As Per Building Specification And Direction Of E/I. , Providing Designation 75A Brick Work In Cement Mortar (1:6) In Foundation And Lintin With Approvedquality Of Clean Coarse Sand F.M. 2 To 2.5Including Providing 10Mm Thick Mortar Joints, Cost Of Screening Materials, Racking Out Joints To 15Mm Depth Curing Taxes And Royalty All Complete As Per Building Specification And Direction Of E/I. , Providing Following Materials As Filter Media In The Pit Of Approved Quality And Size In Layers As Per Drawing And Direction Of Engineer In Charge All Complete Job With All Taxes And Royalty. A) Stone Materials (Confirming To M.O.S.T. Table No.- 400-7) Grade Ii (63-45Mm) , B) Stone Materials (Confirming To M.O.S.T. Table No.- 400-7 Grade Iv , C) Stone Materials (Confirming To M.O.S.T. Table No.- 400-7) Doarse Sand (F.M Greater Than 2) , Providing Precast R.C.C. M-150 With Nominal Mix Of (1:2:4) In Different Place With Approved Quality Of Stone Chips 20Mm To 6Mm Size Graded & Clean Coarse Sand Of Fm 2.5 To 3 Including Screening, Shuttering, Mixing Cement Concrete In Mixer & Placing In Position Vibration, Striking, Curing (But Excluding The Cost Of Reinforcement), Taxes And Royalty All Complete As Per Building Specification And Direction Of E/I. , Providing For Reinforcement As Per Approved Design And Drawing Including Carriage Of Tor Rodto Work Site Including Cutting, Bending And Binding With Anncaled Wire With Cost Of Wire Removal Of Rust Placing The Rodsin Position All Complete As Per Specification And Direction Of E/I. , Providing Fitting And Fixing Suitable M.S. Grating At Inlet Of Soak Pit And Cleaning Of Site For Execution Of Work As Per Direction Of E/I. , Supplying Materials And Construction Of Brick Masonry Drain 150Mm Width And 150Mm Depth With 250Mm Apron On Both Sides Over 50Mm Thick P.C.C (1:3:6) Over A Brick Flat Soling, Apron Laying, Brick Work In C.M (1:6), 12Mm C.P (1:3) With Punning On Exposed Surface All Complete As Per Specification And Direction Of E/I. , Supplying Materials, Labours And Equipments For Construction Of 1.20M X0.90M Size P.C.C (1:2:4) Rectangular Platform Around Stand Post Including 12Mm Thick Cement Plaster In C.M (1:4) With Neat Cement Punning Over Exposed Surface All Complete Job As Per Approved Design, Specification And Direction Of E/I. , Carriage Of Materials Sand Lead From 20 Km , Cement Lead From 20 Km , Brick Lead From 20 Km , Stone Chips Lead From 20 Km , Tor Rod Lead From 20 Km , 18% Gst , Labour Cess
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
38.
Drinking Water Supply and Sanitation #9041122 Technical Bid
Construction For Drinking Water Facility In School Through Hydt With Motor Submersible Pump Set. Under Drinking Water Sanitation Division No 2 Giridih On Turn Key Basis Block Dumri Group No Gir-School-6 , Costofdrilling200 Mm X 165 Mm X 150Mtr M Deep Bore Well In All Kinds Of Soil And Rock In Rural Areas For Installation Of Pump Set With Hydraulic Dth Rig Machine, All Complete Including Supplying All Material Tools Drilling Rig And Air Compressor And Equipments As Well As Fuel Lubricants And Cost Of Transportation Of Rig Machine And Other Vehicles Up To Site Including Cost Of Flushing Charges, Geological Investigation Etc. All Complete As Per Direction Of E/I. 0.00 To 50.00 M , Depth 51.00M - 150.00M , Supplying All Tools, Tackles & Lowering Of 200Mm Dia Ms Casing Pipe Including Cost Of Pipe Etc. Including All Taxes, Vat, Excise Duty, Freight Charges With Inspection Charges Etc. As Aplicable,All Complete Including Carriage To Work Site. , Supplying All Materials Labours, Tools & Equipments For Fitting & Fixing 200Mm Dia M.S. Cap Over Casing Pipe Etc. , Civil Portion Supplying All Tools, Equipments And Labours And Lowering 32Mm Dia G.I. Suspension Pipes In 3 Mtrs. Length In The Drilling Bore Of The Tube Well Etc. All Complete Job As Per Direction Of E/I. , Providing Lobours And Equipments Forfitting And Fixing The Deep Well Cylinderassembly With Necessary Connecting Rods Including Jointing Materials Nitrile Rubber Bucket All Tools And Plants Etc Required For The Job For Low Water Level All Comepete Job As Per Specification And Direction Of E/I. , Providing All Labours & Equipments For Fitting Fixing Of Deep Well Hand Pump India Mark-Ii Including Supplying All Tools And Plant Required For The All Job Complete As Per Specification And Direction Of E/I. , Supplying All Materials Including Cement Of Approved Quality, Labours Tools For Constricting 1.85 M Dia. Circular P.C.C. (1:2:4) Platformincluding 12 Mm Thick Cementplaster The Exposed Surface (1:4) With Neat Cement Punningincluding Providing Necessary Shuttering Curing And Carriage Of Materials To Different Tube Well Sites Etc As Per Unicef Design And Direction Of E/I. , Supplying All Materials Labours And Equpments For Constructing Pcc(1:2:4)Drain As Per Unicef Design Etc All Complete , Cost Of Materials Supplying Extra Deep Well Hand Pump Complete Sets With Cylinder Assembly& Connecting Rod (12 Pcs) As Per Is : 15500 Part-2/ 2004(Basic Rate) . , Cost Of 32Mm Dia G.I. Pipe 3 M. Long Screwed At Both Ends With Seamless Socket As Per Is: 1239Including All Taxes Royalty And Contractor Profit Etc , Reducer Cap For Instatlation Of Hand Pump , Supplying All Materials Tools & Labours For Fitting & Fixing Control Pannel Board, 1No. Star Dealta Air Beak Selector Fully Automatic With Build In Single Phase Prevendor1 No. 3 Phase M.C.C. B Suitable With Suitable Size Of Copper Wire And Connectors Etc. , Supplying & Commissiong Of 5 K.V.A Staiblizer (Range 90 V-300V) Three Phase With Cable, Chnge Over Switch For Submersible Pump Etc. All Comp. As Per Specification And Direction Of E/I. , E/W In Exavation (As Per I.S 3114/1965) For Laying Of 32Mm Dia G.I Pipes So As 1.0 M Av. Cover The Socket Of Pipe ………….. Do ……. Etc All Comp. As Per S/D Of E/I. , E/W In Back Filling In Trenches After Laying Different Type & Size Of Pipe With Eath Remove During Excavation Within Initial Lead & Lift As Per Dirction Of E/I. , Supplying All Tools, Labour, Euipment For Supplying Fitting & Fixingsubmersible Pump Set 1.50 H.P Single Phase With Statrer And Pannel Board According To I.S.I Mark Etc All Comp. Job. 150Mm Dia Bonze Impellar , Providing Fitting & Fixing 3 Core 2.5 Sqm Flate Copper Cable For Submersible Motor Pump. , Providing & Fixing 20Mm Nylon Rope For Hoisting Thesubmersible Motor Pump In Bore Well. , Supplying Upvc Pipe Approved I.S.I Make Etc As Per S/D Of E/I. (For Column Pipe) (A)32Mm Dia Column Pipe 65M , Supplying All Materials ,Labours And Laying G.I. Medium Pipesofapproved Make In Trenches With Red Lead And Yarn With G.I. Socket And Screw Joints And Cutting Pipes To Sizes And Threading Ends Where Necessary Etc. All Complete As Per Specification And Direction Of Engineer-In-Charge A) 32Mm Dia , B) 25Mm Dia , Supplying And Fixing G.I. Fitting Of Approved Make All Complete As Per Specification And Direction Of Engineer-In-Charge.(I)32 Mm Gi Elbow , (Ii)32Mmreducing Socket , (Iii)32Mm Union Socket , (V)32Mmtee , (Ii)25Mmreducing Socket , (V)25Mmtee , (Vii)25 Mm Jam Nut , 15Mm Nipple , 15Mm Socket , Providing And Fixing Of Male Ended C.I.Body Brass Spindle Valve And Seat Bib Cock Of Approved Quality With Extra Socketall Complete As Per Specification And Direction Of E/I. , Providing & Fixing Gm Non-Return Valve Of Approved Quality As Per Specification & Direction Of E/I. 32 Mm Dia , Providing And Fixing Gun Metal Full Way Valves Of Approved Make All Complete As Per Specification And Direction Of Engineer-In-Charge 32 Mm Dia G.M. Full Way Valve Weight Not Less Than 1.5 Kg , Providing Polyvinyle Water Storage Tank(1000 X 2 No= 2000) Of I.S.I Mark (Himgiri/Gangotri) Etc With Cover And Locking Arrangement System Etc. All Comp. Job. , Making Holes In Walls For Laying G.I Pipes And Restoring The Same After Pipe Laying As Per Specification And Direction Of E./I 125Mm Thick , Providing Fitting & Fixing 2 Core 2.5 Sqm Copper Cable Forelectric Connection. , Supplying All Materials Tools Labours And Laying Ofgi Pipe Tata Or Equivalent 32 Mm Dia (In Trench ) , 15 Mm Dia (On Wall) , Supplyingfitting & Fixing.Gifittings Fullway Valve 32Mm , Union Socket 32Mm , Gi Elbow 32Mm , Gi Elbow 15Mm , Gi Tee 32Mm , Gi Tee 15Mm , R/Socket 32Mm , Socket 32Mm , Socket 15Mm , Nipple 15Mm , Earth Work In Excavation In Foundation Trenchesin Hard Soil (Vide Classification Of Soil Item B) And Disposal Of Excavated Earth As Obtained To A Distance Up To 50M Including All Lifts, Leveling, Ramming The Foundation Trenches, Removing Roots Of Trees, Shrubs All Complete As Per Approved Design As Per Building Specification And Direction Of E/I. , Providing Coarse Clean Sand In Filling In Foundation Trenches Or In Lintin Including Ramming And Watering In Layers Not Exceeding 150Mm Thicks With All Leads And Lifts Including Cost Of All Materials, Labours Royalty And Taxes All Complete As Per Building Specification And Direction Of E/I. , Providing Designation 75Aone Brick Flat Soiling Joints Filled With Local Sand Including Cost Of Watering Taxes Royalty All Complete As Per Building Specification And Direction Of E/I. , Providing R.C.C.M - 200 With Nominal Mix Of (1:1.5:3) In Foundation And Plinth With Approved Quality Of Stone Chips 20 Mm To 6 Mm Size Graded And Clean Coarse Sand Of F.M. 2.5 To 3 Including Screening, Shuttering, Mixing Cement Concrete In Mixer And Placing In Position, Vibrating, Striking, Curing (But Excluding The Cost Of Reinforcement) Taxes And Royalty All Complete As Per Building Specification And Direction Of E/L. , Providing R.C.C.M- 200 With Nominal Mix (1:1.5:3) In Columns With Approved Quality Of Stone Chips 20Mm To 6Mm Size Graded And Clean Coarse Sand Of F.M.2.5 To 3 Including, Screening Shuttering Mixing Cement Concrete In Mixer And Placing In Position Vibrating, Striking, Curing Taxes Androyalty All Complete As Per Building Specification And Direction Of E/I , Providing R.C.C.M- 200 With Nominal Mix (1:1:5:3) In Roof Slab With Approved Quality Of Stone Chips 20Mm To 6Mm Size Graded And Clean Coarse Sand Of F.M.2.5 To 3 Including, Screening Shuttering Mixing Cement Concrete In Mixer And Placing In Position Vibrating, Striking, Curing Taxes Androyalty All Complete As Per Building Specification And Direction Of E/I , Dismantling Old Plaster And Pointing In Cement Or Lime And Raking Out Joints To 15 Mm. Depth, Watering And Disposal Of Unserviceable Materials With All Leads All Complete As Per Direction Of E/L , Providing 12Mm Cement Plaster (1:3) With Clean Coarse Sand Of F.M. 1.5 Including Screening, Curingwithall Leadsand Liftsof Water, Scaffolding Taxes And Royalty All Complete As Per Building Specification And Direction Of E/L. , Providing And Laying 6Mm. Thick Rough Grit Cheqer Tiles In Exterior Walls Of Approved Texture And Colour With 4Mm Down Marble Chips Of Approved Shade, Size And Quality With 100% Ordinary Cement Over 12Mm. Thick Cement Plaster (1:3) Base, Cost Of Panels And Finished With Grit Wash And Rubbed To Give Granolithic Finish Including Cost Of Curing, Scaffolding, Finishing, Royalty And Taxes All Complete As Per Specification And Direction Of E/L. , Providing And Laying 25Mm Thick Granite Tiles In Risers Of Steps, Skirting And Pillars Of Approved Size, Texture And Colour Laid Over 12Mm Thick Cement Mortar (1:3) And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab Including Rubbing To Granolithic Finish With Approved Quality Of Carborandum Stone Including Cost Of Curing, Taxes And Royalty All Complete As Per Building Specification And Direction Of E/I. , Providing And Laying 6Mm Precast White Glazed Tiles In Walls Over 12Mm Cement Mortar (1:3) And Jointed With Grey Cement Slurry Flush Pointed With White Cement Including Rubbing, Polishing And Cost Of Curing, Taxes And Royalty All Complete As Per Building Specification And Direction Of E/L. , Carriage Of Materials Sand Lead From 20 Km , Cement Lead From 20 Km , Stone Chips Lead From 20 Km , Tor Rod Lead From 20 Km , Earth Work In Excavation In Foundation Trenchesin Hard Soil (Vide Classification Of Soil Item B) And Disposal Of Excavated Earth As Obtained To A Distance Up To 50M Including All Lifts, Leveling, Ramming The Foundation Trenches, Removing Roots Of Trees, Shrubs All Complete As Per Approved Design As Per Building Specification And Direction Of E/I. , Providing Coarse Clean Sand In Filling In Foundation Trenches Or In Lintin Including Ramming And Watering In Layers Not Exceeding 150Mm Thicks With All Leads And Lifts Including Cost Of All Materials, Labours Royalty And Taxes All Complete As Per Building Specification And Direction Of E/I. , Providing Designation 75Aone Brick Flat Soiling Joints Filled With Local Sand Including Cost Of Watering Taxes Royalty All Complete As Per Building Specification And Direction Of E/I. , Providing Pcc M-100 With Nominal Mix Of (1:3:6) In Foundation With Approved Quality Of Stone Chips 50Mm To 25Mm Size Graded And Clean Coarse Sand Of F.M. 2.5 To 3 Including Screening, Shuttering, Mixing Cement Concrete In Mixer And Placing In Position, Vibrating, Striking, Curing, Taxes And Royalty All Complete As Per Building Specification And Direction Of E/I. , Providing 250Mm Thick Brick Jail Work In C.M. (1:8) In Foundation With Designation 75A Bricks And Approved Quality Of Clean Coarse Sand Finished With Deep Ruled Pointing In C.M. (1:3) All Complete Jobs As Per Building Specification And Direction Of E/I. , Providing Designation 75A Brick Work In Cement Mortar (1:6) In Foundation And Lintin With Approvedquality Of Clean Coarse Sand F.M. 2 To 2.5Including Providing 10Mm Thick Mortar Joints, Cost Of Screening Materials, Racking Out Joints To 15Mm Depth Curing Taxes And Royalty All Complete As Per Building Specification And Direction Of E/I. , Providing Following Materials As Filter Media In The Pit Of Approved Quality And Size In Layers As Per Drawing And Direction Of Engineer In Charge All Complete Job With All Taxes And Royalty. A) Stone Materials (Confirming To M.O.S.T. Table No.- 400-7) Grade Ii (63-45Mm) , B) Stone Materials (Confirming To M.O.S.T. Table No.- 400-7 Grade Iv , C) Stone Materials (Confirming To M.O.S.T. Table No.- 400-7) Doarse Sand (F.M Greater Than 2) , Providing Precast R.C.C. M-150 With Nominal Mix Of (1:2:4) In Different Place With Approved Quality Of Stone Chips 20Mm To 6Mm Size Graded & Clean Coarse Sand Of Fm 2.5 To 3 Including Screening, Shuttering, Mixing Cement Concrete In Mixer & Placing In Position Vibration, Striking, Curing (But Excluding The Cost Of Reinforcement), Taxes And Royalty All Complete As Per Building Specification And Direction Of E/I. , Providing For Reinforcement As Per Approved Design And Drawing Including Carriage Of Tor Rodto Work Site Including Cutting, Bending And Binding With Anncaled Wire With Cost Of Wire Removal Of Rust Placing The Rodsin Position All Complete As Per Specification And Direction Of E/I. , Providing Fitting And Fixing Suitable M.S. Grating At Inlet Of Soak Pit And Cleaning Of Site For Execution Of Work As Per Direction Of E/I. , Supplying Materials And Construction Of Brick Masonry Drain 150Mm Width And 150Mm Depth With 250Mm Apron On Both Sides Over 50Mm Thick P.C.C (1:3:6) Over A Brick Flat Soling, Apron Laying, Brick Work In C.M (1:6), 12Mm C.P (1:3) With Punning On Exposed Surface All Complete As Per Specification And Direction Of E/I. , Supplying Materials, Labours And Equipments For Construction Of 1.20M X0.90M Size P.C.C (1:2:4) Rectangular Platform Around Stand Post Including 12Mm Thick Cement Plaster In C.M (1:4) With Neat Cement Punning Over Exposed Surface All Complete Job As Per Approved Design, Specification And Direction Of E/I. , Carriage Of Materials Sand Lead From 20 Km , Cement Lead From 20 Km , Brick Lead From 20 Km , Stone Chips Lead From 20 Km , Tor Rod Lead From 20 Km , 18% Gst , Labour Cess
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
39.
Drinking Water Supply and Sanitation #9041115 Technical Bid
Construction For Drinking Water Facility In School Through Hydt With Motor Submersible Pump Set. Under Drinking Water Sanitation Division No 2 Giridih On Turn Key Basis Block Bagodar Group No Gir-School-7 , Costofdrilling200 Mm X 165 Mm X 150Mtr M Deep Bore Well In All Kinds Of Soil And Rock In Rural Areas For Installation Of Pump Set With Hydraulic Dth Rig Machine, All Complete Including Supplying All Material Tools Drilling Rig And Air Compressor And Equipments As Well As Fuel Lubricants And Cost Of Transportation Of Rig Machine And Other Vehicles Up To Site Including Cost Of Flushing Charges, Geological Investigation Etc. All Complete As Per Direction Of E/I. 0.00 To 50.00 M , Depth 51.00M - 150.00M , Supplying All Tools, Tackles & Lowering Of 200Mm Dia Ms Casing Pipe Including Cost Of Pipe Etc. Including All Taxes, Vat, Excise Duty, Freight Charges With Inspection Charges Etc. As Aplicable,All Complete Including Carriage To Work Site. , Supplying All Materials Labours, Tools & Equipments For Fitting & Fixing 200Mm Dia M.S. Cap Over Casing Pipe Etc. , Civil Portion Supplying All Tools, Equipments And Labours And Lowering 32Mm Dia G.I. Suspension Pipes In 3 Mtrs. Length In The Drilling Bore Of The Tube Well Etc. All Complete Job As Per Direction Of E/I. , Providing Lobours And Equipments Forfitting And Fixing The Deep Well Cylinderassembly With Necessary Connecting Rods Including Jointing Materials Nitrile Rubber Bucket All Tools And Plants Etc Required For The Job For Low Water Level All Comepete Job As Per Specification And Direction Of E/I. , Providing All Labours & Equipments For Fitting Fixing Of Deep Well Hand Pump India Mark-Ii Including Supplying All Tools And Plant Required For The All Job Complete As Per Specification And Direction Of E/I. , Supplying All Materials Including Cement Of Approved Quality, Labours Tools For Constricting 1.85 M Dia. Circular P.C.C. (1:2:4) Platformincluding 12 Mm Thick Cementplaster The Exposed Surface (1:4) With Neat Cement Punningincluding Providing Necessary Shuttering Curing And Carriage Of Materials To Different Tube Well Sites Etc As Per Unicef Design And Direction Of E/I. , Supplying All Materials Labours And Equpments For Constructing Pcc(1:2:4)Drain As Per Unicef Design Etc All Complete , Cost Of Materials Supplying Extra Deep Well Hand Pump Complete Sets With Cylinder Assembly& Connecting Rod (12 Pcs) As Per Is : 15500 Part-2/ 2004(Basic Rate) . , Cost Of 32Mm Dia G.I. Pipe 3 M. Long Screwed At Both Ends With Seamless Socket As Per Is: 1239Including All Taxes Royalty And Contractor Profit Etc , Reducer Cap For Instatlation Of Hand Pump , Supplying All Materials Tools & Labours For Fitting & Fixing Control Pannel Board, 1No. Star Dealta Air Beak Selector Fully Automatic With Build In Single Phase Prevendor1 No. 3 Phase M.C.C. B Suitable With Suitable Size Of Copper Wire And Connectors Etc. , Supplying & Commissiong Of 5 K.V.A Staiblizer (Range 90 V-300V) Three Phase With Cable, Chnge Over Switch For Submersible Pump Etc. All Comp. As Per Specification And Direction Of E/I. , E/W In Exavation (As Per I.S 3114/1965) For Laying Of 32Mm Dia G.I Pipes So As 1.0 M Av. Cover The Socket Of Pipe ………….. Do ……. Etc All Comp. As Per S/D Of E/I. , E/W In Back Filling In Trenches After Laying Different Type & Size Of Pipe With Eath Remove During Excavation Within Initial Lead & Lift As Per Dirction Of E/I. , Supplying All Tools, Labour, Euipment For Supplying Fitting & Fixingsubmersible Pump Set 1.50 H.P Single Phase With Statrer And Pannel Board According To I.S.I Mark Etc All Comp. Job. 150Mm Dia Bonze Impellar , Providing Fitting & Fixing 3 Core 2.5 Sqm Flate Copper Cable For Submersible Motor Pump. , Providing & Fixing 20Mm Nylon Rope For Hoisting Thesubmersible Motor Pump In Bore Well. , Supplying Upvc Pipe Approved I.S.I Make Etc As Per S/D Of E/I. (For Column Pipe) (A)32Mm Dia Column Pipe 65M , Supplying All Materials ,Labours And Laying G.I. Medium Pipesofapproved Make In Trenches With Red Lead And Yarn With G.I. Socket And Screw Joints And Cutting Pipes To Sizes And Threading Ends Where Necessary Etc. All Complete As Per Specification And Direction Of Engineer-In-Charge A) 32Mm Dia , B) 25Mm Dia , Supplying And Fixing G.I. Fitting Of Approved Make All Complete As Per Specification And Direction Of Engineer-In-Charge.(I)32 Mm Gi Elbow , (Ii)32Mmreducing Socket , (Iii)32Mm Union Socket , (V)32Mmtee , (Ii)25Mmreducing Socket , (V)25Mmtee , (Vii)25 Mm Jam Nut , 15Mm Nipple , 15Mm Socket , Providing And Fixing Of Male Ended C.I.Body Brass Spindle Valve And Seat Bib Cock Of Approved Quality With Extra Socketall Complete As Per Specification And Direction Of E/I. , Providing & Fixing Gm Non-Return Valve Of Approved Quality As Per Specification & Direction Of E/I. 32 Mm Dia , Providing And Fixing Gun Metal Full Way Valves Of Approved Make All Complete As Per Specification And Direction Of Engineer-In-Charge 32 Mm Dia G.M. Full Way Valve Weight Not Less Than 1.5 Kg , Providing Polyvinyle Water Storage Tank(1000 X 2 No= 2000) Of I.S.I Mark (Himgiri/Gangotri) Etc With Cover And Locking Arrangement System Etc. All Comp. Job. , Making Holes In Walls For Laying G.I Pipes And Restoring The Same After Pipe Laying As Per Specification And Direction Of E./I 125Mm Thick , Providing Fitting & Fixing 2 Core 2.5 Sqm Copper Cable Forelectric Connection. , Supplying All Materials Tools Labours And Laying Ofgi Pipe Tata Or Equivalent 32 Mm Dia (In Trench ) , 15 Mm Dia (On Wall) , Supplyingfitting & Fixing.Gifittings Fullway Valve 32Mm , Union Socket 32Mm , Gi Elbow 32Mm , Gi Elbow 15Mm , Gi Tee 32Mm , Gi Tee 15Mm , R/Socket 32Mm , Socket 32Mm , Socket 15Mm , Nipple 15Mm , Earth Work In Excavation In Foundation Trenchesin Hard Soil (Vide Classification Of Soil Item B) And Disposal Of Excavated Earth As Obtained To A Distance Up To 50M Including All Lifts, Leveling, Ramming The Foundation Trenches, Removing Roots Of Trees, Shrubs All Complete As Per Approved Design As Per Building Specification And Direction Of E/I. , Providing Coarse Clean Sand In Filling In Foundation Trenches Or In Lintin Including Ramming And Watering In Layers Not Exceeding 150Mm Thicks With All Leads And Lifts Including Cost Of All Materials, Labours Royalty And Taxes All Complete As Per Building Specification And Direction Of E/I. , Providing Designation 75Aone Brick Flat Soiling Joints Filled With Local Sand Including Cost Of Watering Taxes Royalty All Complete As Per Building Specification And Direction Of E/I. , Providing R.C.C.M - 200 With Nominal Mix Of (1:1.5:3) In Foundation And Plinth With Approved Quality Of Stone Chips 20 Mm To 6 Mm Size Graded And Clean Coarse Sand Of F.M. 2.5 To 3 Including Screening, Shuttering, Mixing Cement Concrete In Mixer And Placing In Position, Vibrating, Striking, Curing (But Excluding The Cost Of Reinforcement) Taxes And Royalty All Complete As Per Building Specification And Direction Of E/L. , Providing R.C.C.M- 200 With Nominal Mix (1:1.5:3) In Columns With Approved Quality Of Stone Chips 20Mm To 6Mm Size Graded And Clean Coarse Sand Of F.M.2.5 To 3 Including, Screening Shuttering Mixing Cement Concrete In Mixer And Placing In Position Vibrating, Striking, Curing Taxes Androyalty All Complete As Per Building Specification And Direction Of E/I , Providing R.C.C.M- 200 With Nominal Mix (1:1:5:3) In Roof Slab With Approved Quality Of Stone Chips 20Mm To 6Mm Size Graded And Clean Coarse Sand Of F.M.2.5 To 3 Including, Screening Shuttering Mixing Cement Concrete In Mixer And Placing In Position Vibrating, Striking, Curing Taxes Androyalty All Complete As Per Building Specification And Direction Of E/I , Dismantling Old Plaster And Pointing In Cement Or Lime And Raking Out Joints To 15 Mm. Depth, Watering And Disposal Of Unserviceable Materials With All Leads All Complete As Per Direction Of E/L , Providing 12Mm Cement Plaster (1:3) With Clean Coarse Sand Of F.M. 1.5 Including Screening, Curingwithall Leadsand Liftsof Water, Scaffolding Taxes And Royalty All Complete As Per Building Specification And Direction Of E/L. , Providing And Laying 6Mm. Thick Rough Grit Cheqer Tiles In Exterior Walls Of Approved Texture And Colour With 4Mm Down Marble Chips Of Approved Shade, Size And Quality With 100% Ordinary Cement Over 12Mm. Thick Cement Plaster (1:3) Base, Cost Of Panels And Finished With Grit Wash And Rubbed To Give Granolithic Finish Including Cost Of Curing, Scaffolding, Finishing, Royalty And Taxes All Complete As Per Specification And Direction Of E/L. , Providing And Laying 25Mm Thick Granite Tiles In Risers Of Steps, Skirting And Pillars Of Approved Size, Texture And Colour Laid Over 12Mm Thick Cement Mortar (1:3) And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab Including Rubbing To Granolithic Finish With Approved Quality Of Carborandum Stone Including Cost Of Curing, Taxes And Royalty All Complete As Per Building Specification And Direction Of E/I. , Providing And Laying 6Mm Precast White Glazed Tiles In Walls Over 12Mm Cement Mortar (1:3) And Jointed With Grey Cement Slurry Flush Pointed With White Cement Including Rubbing, Polishing And Cost Of Curing, Taxes And Royalty All Complete As Per Building Specification And Direction Of E/L. , Carriage Of Materials Sand Lead From 20 Km , Cement Lead From 20 Km , Stone Chips Lead From 20 Km , Tor Rod Lead From 20 Km , Earth Work In Excavation In Foundation Trenchesin Hard Soil (Vide Classification Of Soil Item B) And Disposal Of Excavated Earth As Obtained To A Distance Up To 50M Including All Lifts, Leveling, Ramming The Foundation Trenches, Removing Roots Of Trees, Shrubs All Complete As Per Approved Design As Per Building Specification And Direction Of E/I. , Providing Coarse Clean Sand In Filling In Foundation Trenches Or In Lintin Including Ramming And Watering In Layers Not Exceeding 150Mm Thicks With All Leads And Lifts Including Cost Of All Materials, Labours Royalty And Taxes All Complete As Per Building Specification And Direction Of E/I. , Providing Designation 75Aone Brick Flat Soiling Joints Filled With Local Sand Including Cost Of Watering Taxes Royalty All Complete As Per Building Specification And Direction Of E/I. , Providing Pcc M-100 With Nominal Mix Of (1:3:6) In Foundation With Approved Quality Of Stone Chips 50Mm To 25Mm Size Graded And Clean Coarse Sand Of F.M. 2.5 To 3 Including Screening, Shuttering, Mixing Cement Concrete In Mixer And Placing In Position, Vibrating, Striking, Curing, Taxes And Royalty All Complete As Per Building Specification And Direction Of E/I. , Providing 250Mm Thick Brick Jail Work In C.M. (1:8) In Foundation With Designation 75A Bricks And Approved Quality Of Clean Coarse Sand Finished With Deep Ruled Pointing In C.M. (1:3) All Complete Jobs As Per Building Specification And Direction Of E/I. , Providing Designation 75A Brick Work In Cement Mortar (1:6) In Foundation And Lintin With Approvedquality Of Clean Coarse Sand F.M. 2 To 2.5Including Providing 10Mm Thick Mortar Joints, Cost Of Screening Materials, Racking Out Joints To 15Mm Depth Curing Taxes And Royalty All Complete As Per Building Specification And Direction Of E/I. , Providing Following Materials As Filter Media In The Pit Of Approved Quality And Size In Layers As Per Drawing And Direction Of Engineer In Charge All Complete Job With All Taxes And Royalty. A) Stone Materials (Confirming To M.O.S.T. Table No.- 400-7) Grade Ii (63-45Mm) , B) Stone Materials (Confirming To M.O.S.T. Table No.- 400-7 Grade Iv , C) Stone Materials (Confirming To M.O.S.T. Table No.- 400-7) Doarse Sand (F.M Greater Than 2) , Providing Precast R.C.C. M-150 With Nominal Mix Of (1:2:4) In Different Place With Approved Quality Of Stone Chips 20Mm To 6Mm Size Graded & Clean Coarse Sand Of Fm 2.5 To 3 Including Screening, Shuttering, Mixing Cement Concrete In Mixer & Placing In Position Vibration, Striking, Curing (But Excluding The Cost Of Reinforcement), Taxes And Royalty All Complete As Per Building Specification And Direction Of E/I. , Providing For Reinforcement As Per Approved Design And Drawing Including Carriage Of Tor Rodto Work Site Including Cutting, Bending And Binding With Anncaled Wire With Cost Of Wire Removal Of Rust Placing The Rodsin Position All Complete As Per Specification And Direction Of E/I. , Providing Fitting And Fixing Suitable M.S. Grating At Inlet Of Soak Pit And Cleaning Of Site For Execution Of Work As Per Direction Of E/I. , Supplying Materials And Construction Of Brick Masonry Drain 150Mm Width And 150Mm Depth With 250Mm Apron On Both Sides Over 50Mm Thick P.C.C (1:3:6) Over A Brick Flat Soling, Apron Laying, Brick Work In C.M (1:6), 12Mm C.P (1:3) With Punning On Exposed Surface All Complete As Per Specification And Direction Of E/I. , Supplying Materials, Labours And Equipments For Construction Of 1.20M X0.90M Size P.C.C (1:2:4) Rectangular Platform Around Stand Post Including 12Mm Thick Cement Plaster In C.M (1:4) With Neat Cement Punning Over Exposed Surface All Complete Job As Per Approved Design, Specification And Direction Of E/I. , Carriage Of Materials Sand Lead From 20 Km , Cement Lead From 20 Km , Brick Lead From 20 Km , Stone Chips Lead From 20 Km , Tor Rod Lead From 20 Km , 18% Gst , Labour Cess
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
40.
Drinking Water Supply and Sanitation #8962450 Technical Bid
Construction Of Mini Rural Water Supply Scheme Solar Motor Pump Complete Set In Block Giridih Panchayat Sihodih Village Bhalsumiya Svs Group Of Scheme Under Jjm D.W.S. Division, No 2 Giridih For The Year 2021-22 Group No Svs-04 Construction Of Mini Rural Water Supply Scheme Solar Motor Pump Complete Set In Block Giridih Panchayat Sihodih Village Bhalsumiya Svs Group Of Scheme Under Jjm D.W.S. Division, No 2 Giridih For The Year 2021-22 Group No Svs-04 , Model:- 1B, 1 No. , Village:- Bhalsumiya , Tola:- Khas , Tube Well , Drilling Portion , Construction For 115 / 125 Mm Dia Drilled Tube-Well For Drilling In All Kinds Of Soil Rock For Installation Of Hand Pump With D.T.H Rig Machine All Complete Including Supplying All Materials, Labours, Tools, Drilling, Rigs, Air Compressor And Equipments As Well As Fuel Lubricant For Making 125 / 115 Mm Dia Boring Etcand Cost Of Transporting Rig Machine And Other Vehicle Up To Site Workas Per Specification And Direction Of Engineer-In-Charge. , ( A ) Up To 30Mtr. Depth Bellow G.L. In Rural Areas , ( B ) Beyond 30Mtr.In Rural Areas , Providing All Equipments And Labour For Lowering 125Mm Dia Blue Upvc Casing Pipe As Casing For Protecting The Side From Falling During The Process Of Drilling All Complete Job Including Carriage Of Material To Work Site. , Supplying Labour Cement And Calcium Chloride Or Bentonite Solution And Equipments For Grouting To Casing Pipe All Complete Job Including Carriage Of Material To Work Site As Per Specification & Direction Of E / I , Supplying All Tools, Equipments And Labour And Doing Washing, Flushing And Development Of Drilled Tube Well To Give Clean And Clear Water All Complete As Per Direction E / I. , Supplying All Materials Labours And Equipment Including 125 Mm Dia Gi / Ci Cap 125 Mm Dia T / W Properly All Complete And Taking It Out As Per Specification & Direction Of E / I. ( The Cap Will Be Property Of Department ) , Civil Portion , Supplying All Tools, Equipment, Labours And Lowering 32 Mm Dia G.I. ( Medium ) Pipe In Dt In 3 Mtr. Length All Complete Job As Per Direction Of E / I. Including Carriage Of Materials. , Supplying All Tools, Labour For Fitting And Fixing Deep Well Cylinder With Necessary Connecting Rod All Complete Job As Per Specification & Direction Of E / I. , Supplying All Materials, Labours For Fitting And Fixing Of India Mark Ii Hand Pump With All Accessories All Job Complete As Per Direction Of E / I. Including Carriage Of Materials. , Supplying All Materials, Labours And Equipment For Constructing Pcc ( 1:2:4 ) Circular Platform Around Each Drilled Tube Well Including 12Mm Thick Cement Plaster ( 1:4 ) With Neat Cement Punning Over Exposed Surface As Per Unicef Design Etc. All Complete. Including Carriage Of Materials. , Supplying All Materials Labour And Equipment For Constructing Pcc ( 1:2:4 ) Drain As Per Unicef Design Etc. All Complete .Including Carriage Of Materials. , Add Extra Item For Supplying Tools, Labours And Materials For Painting, Numbering And Year For Construction Of T / Well And Taking Of Colour Photograph With Two Or Three Nearest Persons Including Platform, Drain, Soak Pit And Also Longitude & Latitude, Details Of T / W Such As Total Depth, Casing Depth, Static Water Level, Drawdown, Discharge, Strata Chart, Beneficiary Population Etc In Separate Sheet / Format All Complete As Per Direction Of E / I. , Cost Of Materials , Cost Of Standard I.S.I. Mark Deep Well Hand Pump For India Mark-Ii, I.S.I. 15500 ( Part 2 ) / 2004 With Latest Revision Including 12Mm X 3 Meter Long 8 No. Connecting Rods Made Of Bright Bar Electro-Galvanized Fitted With Coupler & Normal Stand Assembly Recommended For Use With Cylinder Assembly Suitable For Bore Wellcasing Pipe. , Cost Of 32 Mm Dia Gi Pipe ( Medium ) 3 Mtrs Long Screwed At Both Ends With Seamless Socket As Per Is:1239 ( Part 1990 ) . , Cost Of 125 Mm Dia Blue Upvc Casing Pipe As Per I.S.12818 / 2016 Cml No.- 5543459 , Rcc Foundation For Steel Structurestaging& Solar Panel , Earth Work In Excavation In Foundation Trenches In Ordinary Soil And Disposal Of Excavated Earth As Obtained To A Distance Up To 50.0M , Including All Lifts, Levelling , Ramming The Foundation Trenches, Removing Roots Of Trees, Shrubs All Complete As Per Approved Design , Building Specification And Direction Of E / I ( Vide Classification Of Soil Item -B ) , Providing Coarse Clean Sand In Filling In Foundation Trenches Or In Plinth Including Ramming And Watering In Layers Not Exceeding 150Mm Thick With All Leads And Lifts Including Cost Of All Materials , Labour , Royalty And Taxes All Complete As Per Building Specification And Direction Of E / I , Providing Designation 75 A One Brick Flat Soling Joints Filled With Local Sand Including Cost Of Watering Taxes Royalty All Complete As Per Building Specification And Direction Of E / I , Providing Nominal Mix Pcc Of ( 1:4:8 ) In Foundationwith Approved Quality Of Stone Chips 20Mm To 6Mm Size Graded And Clean Coarse Sand Of F.M.2.5To 3 Including Screening Shuttering Mixing Cement Concrete In Mixer And Placing In Position Vibrating Striking Curing And Royalty All Complete As Per Building Specification And Direction Of E / I , Providing Rcc M-20 In Nominal Mix Of ( 1:1.5:3 ) In Columnswith Approved Quality Of Stone Chips 20Mm To 6Mm Size Graded And Clean Coarse Sand Of F.M.2.5To 3 Including Screening Shuttering Mixing Cement Concrete In Mixer And Placing In Position Vibrating Striking Curing And Royalty All Complete As Per Building Specification And Direction Of E / I. , ( A ) Foundation For Steel Structure Staging , Footing And Vertical Pedestal Raft , Column , Tie Beam , ( B ) Foundation For Solar Panel , Footing , Vertical Pedestal , Providing For Steel Reinforcement As Per Approved Design And Drawing Excluding Carriage Of T.S. Bar To Work Site Cutting, Bending With Annealed Wire With Cost Of Wire, Removal Of Rust Placing The Rods In Position All Complete As Per Building Specification And Direction Of E / I. , ( A ) Foundation For Steel Structure Staging , Carriage Of Materials From Different Sources Or Departmental Stores To Work Site Including Loading, Transporting, Unloading And Stacking The Materials At Work Site Etc. All Complete Job. As Per Direction Of E / I. , Cement Lead 20 Km ( Avg. ) , Sand Lead 20 Km ( Avg. ) , Stone Chips Lead 20 Km ( Avg. ) , Steel Reinforcement Lead 20 Km ( Avg. ) , Bricks Lead 20 Km ( Avg. ) , Galvanized Tubular Steel Structure Staging Forhdpe Water Storage Tank& Solar Panel , Providing Structural Steel Galvanisedsqure Pipe Section Work In Trusses, Other Similar Trussed Purlins And Members With All Bracing , Gusset Plates Etc As Per Detailed Design And Drawing Or As Directed By Engineer- In-Charge , Including Cutting Fabricating , Hoisting , Erecting And Fixing In Position , Making Riveted / Bolted / Welded Connections And One Coat Of Anticorrosive Paint And Over It Two Coat Of All Oil Painting & For Structure ( Plus ) Providing And Applying Materials &Labour For Hot Dip Galvanizing Of Above Structure Including Transportation For Galvanizing Minimum Thickness 80Microns ( Net Wt. Of Components To Be Galv ) Preferably Tata Structural Section Etc Complete. , Hardware ( L.S. ) , Information Board For Iec , Installation Of 5000 Liters Capacity Water Storage Tank , Providing And Fixing Hdpe Container Syntex Or Alike One Piecemolded Water Tank Made Out Of Low Density Polythyler Andbuilt Corrugation Including Of Delivery Up To Destination Hoisting And Fixing Of Accessories Such As Inlet, Outlet Overflow Of All Tanks Capacity 5000.00 Litres Capacity Water Storage Tank , Transportation Charge , Lifting Of 5000 Litrs Capacity Tank Up To 4.00M Height With Lifting Tools With Rope And Labour , Making Hole In Tank , Making Long Screw In G.I. Pipe Including Supplying And Fitting Jam Nuts And Extra Socket Etc. , Rising And Distribution Network With House Connection Up To 20 Nos. Including Platform & Stand Post , Earth Work In Excavation In Foundation Trenches In Hard Soil ( Vide Classification Soil Item B ) And Disposal Of Excavated Earth As Obtained To A Distance Up To 50 Mtr. Including All Lifts, Leveling, Ramming The Foundation Trenches, Removing Roots Of Trees, Shrubs All Complete As Per Approved Design, Specification And Direction Of E / I. , Dismantling Plain Cement Concrete Work Including Stacking Serviceable Materials In Countable Stacks Within 15 M Lead And Disposal Of Unserviceable Materials With All Leads All Complete , Providing Pccm-200 With Nominal Mix Of ( 1:1.5:3 ) With Approved Quality Of Stone Chips 20 Mm To 6 Mm Size Graded And Clean Coarse Sand Of Fm 2.5 To 3.0 Including Screening, Shuttering, Mixing Cement Concrete In Mixer And Placing In Position, Vibrating, Sticking, Curing , Taxes And Royalty All Complete As Per Specification And Direction Of E / I. For Construction Of Road Cutting Portion , Rising Main , Manufacture, Supply And Delivery Offollowing Nominal Dia Upvc Column Pipes Including Pvc Socket ( Coupler ) , , 65Mm Dia -Density Of Pipe 1.38 To 1.43 Gm Per Cm3 Od:74.5 To 75.2Mm Wall Thickness End:9Mm To 10.7Mm, Barrel 9Mm To 10.7 Mm, Length: 3Mtrs.Rising Main , 50 Mm Dia -Density Of Pipe 1.38 To 1.43 Gm Per Cm3 Od:87.5 To 88.2Mm Wall Thickness End:9 .8 Mm To 11.9Mm, Barrel 7.3Mm To 9 Mm, Length: 3Mtrs. Delivery Pipe , Distribution , Providing And Supplying High Density Polyethylene Pipe ( Hdpe Pipe ) Of 20 Mm To 225 Mm Od And Pressure 6.0 Kg / Cm2 And 10 Kg / Cm2 Suitable For Water Supply Which Is Available In All Standard Conforming To Isi -- 4984 / 14151 / 12786 / 13488, Iso 4427 , Din-8074Materials Rates Are Ex-Factory Excluding Transportation, Taxes And Duties. , 63 Mm Hdpe Pipe , 50 Mm Hdpe Pipe , 32 Mm Hdpe Pipe , 20 Mm Hdpe Pipe , Providing And Fixing Gun Metal Gate Valvewith C I Wheel Of Approved Quality ( Screwed End ) . , 65Mm Dia , 50Mm Dia , Providing And Supplying High Density Polyethylene ( Hdpe ) Fittings Of 20 Mm To 225 Mm Od And Pressure 6.0 Kg / Cm2 And 10 Kg / Cm2 Suitable For Water Supply Which Is Available In All Standard Conforming To Isi -- 4984 / 14151 / 12786 / 13488, Iso 4427 , Din-8074Materials Rates Are Ex-Factory Excluding Transportation, Taxes And Duties. , Lowering, Laying And Jointing H. D. P. E. / M. D.P. E. Pipes In Proper Position Including All Specials By Compression Fitting / Electro Fusion And Butt Fusion Jointing Procedure As Per Relevant Is Code Complete With All Materials For Jointing Procedure Like Electro Fusion Machine, Electric Heater / Butt Fusion Welding Machine With Hydraulic Jack, Top Loading Clamp Etc. And All Labours As Directed By Engineer In Charge As Per Is-7634 Part Ii. , For Rising , 65 Mm Hdpe Pipe , 50 Mm Hdpe Pipe , Distribution , 65 Mm Hdpe Pipe , 50 Mm Hdpe Pipe , 32 Mm Hdpe Pipe , 20 Mm Hdpe Pipe , Providing 15 Mm Dia. G.I. Pipe Tata Or Equivalent Make As Per Is 1239 ( Part 1 / 2004 ) Isi Mark / Medium Quality In Stand Post. , Supplying All Materials , Labour And Tools For Fixing 15 Mm Dia G.I. Pipes With Red Lead And Yarn Of Following Nominal Bore With Screwed And Socketed Joints On Wall, Ceiling And Floor Including Supplying And Fitting Of Wall Hooks Or Pipe Clamps, Wooden Plugs, Cutting Pipes To Size And Threading Ends If Required Etc. All Complete As Per Specification And Direction Of Engineer-In-Charge. , Supplying And Fixing G.I. Fittings Of Approved Make All Complete As Per Specification And Direction Of E / I. , Elbow 15 Mm Dia. , Reducer Socket 20X15 Mm Dia. , Nipple 15 Mm Dia. , Plain Socket 15 Mm Dia. , Supplying And Fixing G.M. Ferrule Of Approved Make In Existing C.I. / D.I. Main Including Drilling And Taping C.I. / D.I. Main All Complete As Per Specification And Direction Of E / I. 3 Mm, 6 Mm 10 Mm Dm Ferrule Weight Not Less Than 425 Gram. , Providing And Fixing Gun Metal Full Way Valve Of Approved Quality, All Complete, As Per Specification And Direction Of E / I. , 65 Mm Dia Full Way Valve , 50 Mm Dia And Weight Not Less Than 1.5 Kg. , Providing And Fixing Of Male Ended C.I.Body Brass Spindle Valve And Seat Bib Cock Of Approved Quality With Extra Socketall Complete As Per Specification And Direction Of E / I. , 15 Dia And Weight Not Less Than 400 Gm , Constructing Masonry Chamber 30X30x50 Cm Inside, In Brick Work In Cement Mortar 1:4 ( 1 Cement :4 Coarse Sand ) For Stop Cock, With C. I. Surface Box 100X100 X75 Mm ( Inside ) With Hinged Cover Fixed In Cement Concrete Slab 1:2:4 Mix ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size ) , I / C Necessary Excavation, Foundation Concrete 1:5:10 ( 1 Cement : 5 Fine Sand : 10 Graded Stone Aggregate 40Mm Nominal Size ) And Inside Plastering With Cement Mortar 1:3 ( 1 Cement : 3 Coarse Sand ) 12Mm Thick, Finished With A Floating Coat Of Neat Cement Complete As Per Standard Design.With Common Burnt Clay F.P.S. ( Non Modular ) Bricks Of Class Designation 7.5. Full Way Valve Chamber , Supplying Materials , Labours And Equipments For Construction Of 0.90M X 0.90 M Size P.C.C. ( 1:2:4 ) Rectangular Platform With Stand Post In House Including 12 Mm Thick Cement Plaster In C.M. ( 1:4 ) With Neat Cement Punning Over Exposed Surfaceall Complete Job, As Per Approved Design, Specification And Direction Of E / I. , Providing Brick Masonry Chamber Ofinner Size 600 X 600 X 450 Mm Deep For Bore Well Protection Having 125 Mm Thick Wall And 75 Mm R.C.C Cover Including Cement Plaster Of Exposed Surface, Etc All Complete Job , Earth Work In Back Filling The Trenches After Laying Different Types And Size Of Pipes With Earth Removed During Excavation Within Initial Lead And Lift As Per Specification And Direction Of Engineer-In-Charge. , Providing Fitting & Fixing 32 Mm To 50 Mm Service Hdpe Saddleall Complete Job, As Per Approved Design, Specification And Direction Of E / I. , Solar Photovoltaic ( Spv ) Solar Submersible D.C. Water Motor Pump , Designing, Supplying, Installation, Testing & Commissioning With All Tools & Parts Of Following Solar Photovoltaic ( Spv ) Solar Submersible D.C. Water Motor Pump Suitable For Minimum 125Mm X 115Mm Bore Well As Per Mnre Guideline With Following Specifications & Accessories. , Spv Arrays Contains Specified No Of Same Capacity Type & Specification Modules Connected To Series Or Parallel To Obtained The Required Voltage & Current The Power Output Of Individual Pvmodules Should Be Minimum 200 Watt Peak. , I ) The Spv Modules Should Be As Per Iec-61215 And Iec 61730 Part 1.0 ) , Ii ) All External Parts Of Motor Pump Used In Submersible Pump Which Are In Contact Of Water Is Stainless Steel Grade 303 Or Higher As Required. , Iii ) The Pv Modules Shouldbe Mounted On Metallic Structure Of Adequate Strength And Appropriate Design Which Can Withstand Load Of Modules & High Wind Pressure Up To 200Km / H. , Iv ) The Module Mounting Structure Should Be Hot Dip Galvanized According To Is 4759. , V ) To Enhance The Performance Of Spv Water Pumping System & Arrangement For Seasonal Tilt Angle Adjustment Should Be Provided , Vi ) Necessary Arrangement Should Be Provided In Controller Automatic Start-Run-Stop Through Out The Day With Water Level Detection System. ( As Per Mnre Specification ) , Vii ) Necessary Protection Such As Lightening Arrestor Etc. Should Be Provided To Protect The Controller & Spv , Viii ) The Suction / Delivery Pipe Shall Be Upvc / H.D.P.E. Pipes Of Appropriate Size 60M Or More As Required Minimum Pressure Rating Of 8Kg / Sq Cm- Pe 100 Grade For Pump Up To 3Hp & 10 Kg / Sq Cm- Pe 100 Grade For 5 Hp. , Ix ) All Cable Used Shall Be As Per Is 694. Suitable Size Of Cable Shall Be Used In Sufficient Length For Inter Connection Between The Spv Array To Spv Controller And Spv Controller To Solar Power Pump. Provision Of Cable Shall Be As Per Is 14536. , X ) The Motor Pump Set Should Have A 5 Years Warranty. , Xi ) Control Panel Suitable For Motor Pump With Arrangement Of Dry Run & Over Flow Protection Sensor, Float Switch & Rain Prevention Box. ( As Per Mnre Specification ) , Xii ) The Spv Controller Must Have Ip-65 Protection Or Must Be Housed In Cabinet Having At Least Ip-65 Protection. , Xiii ) The System Should Be As Per Mnre Guide Line & Eco-Friendly With Suitable Arrangement To Operate New Pump Manually. , Xiv ) With Third Party Inspection Before Dispatch. , Xv ) Provision For Web Basedremote Monitoring Of The Pumps To Be Installed Must Be Made Through The Inbuilt Controllers . It Should Be Possible To Ascertain The Daily Water Output, The Power Generated By Pv Array , The Up And Downtime Of The Pump During The Year, Number Of Days The Pump Was Unused Or Under Breakdown Repairs. , The Following Details Should Be Marked Indelibly On The Motor Pump Set , A ) Name Of The Manufacturer Or Distinctive Logo. , B ) Model Number. , C ) Serial Number. , Solar Submersible Motor Pump ( Spv Dc Type ) , I ) 1 Hp ( Dc Pump ) With 900 Wp Minimum Watt P.V. Panel As Mnre Pump Head Max Shut-Off Head Up To 120 Mtrs. For Higher Or Lower Head Or In Between Various Modules Output Could Be Decided On Prorates Basis. ( As Per Latest Guide Line Of Mnre ) , Carrying Out Recuperation / Yield Test For Ascertaining The Discharge Of Constructed Well / Excavated Profile As Directed By The Iec. The Testout By The Drawing Down Water From The Well / Profile Below Normal / Subsoil Water Level Up To Full Depth Rise Is Recorded The Normal Water Level / Subsoil Water Level In The Well / Profile As Well As Strainer / Level At Pump As Per Design Of W.S. Scheme Shall Be Recorded Prior To The Test Including Cost Of All Materials, Over Load , Labours Etc. Complete As Directed. , Supplying All Labours, Tools And Equipments For Dismantling Of Head & Water Tank Assembly And Taking Out 32 Mm Dia Old G.I. Pipe, Connecting Rod, Cylinder Assembly The Dismantled Components After Necessary Changing For Making The T / W In Good Condition With All Transportation Including Unused Taken Out Materials Back In Store All Complete Job As Per Direction Of E / I. ( As Per Model Estimate Of Solar Energy Based Mini Wss. Ts Done By Se, Ranchi Circle & Circle Gumla Dt. 21.05.2019 ) , Provision Of Solar Night Lamp. , Galvanised Chain-Line Mess Fencing Around Solar Panel Where Bore Well Is Away From Tower , Making 30 Cm ( 12 ) Dia Bore Up To 4M Below Ground With Hand Auger Of Approved Quality In Ordinary Soil ( Vide Classification Of Soil Item-A ) True To Plum And Without Eccentricity In Any Stage Of Operation And Disposal Of The Exacavated Earth Up To 50M Lead Including All Lifts All Complete As Per Approved Design And Direction Of E / I. , Providing Pcc M-150 In Nominal Mix Of ( 1:2:4 ) In Foundationwith Approved Quality Of Stone Chips 20Mm To 6Mm Size Graded And Clean Coarse Sand Of F.M.2.5 To 3 Including Screening Shuttering, Mixing Cement Concrete In Mixer And Placing In Position, Vibrating, Curing, Taxes And Royalty All Complete As Per Building Specification Direction Of E / I. , Labour Cost Of Fitting And Fixing Galvanised Chain-Link Mess Up Height Of 2 M Including Cost Of Staples ( But Excluding The Cost Of Cement Concete Angle Iron Posts, Its Cutting And Making Holes, Nuts And Bolts ) All Complete As Per Specification And Direction Of E / I. , Drilling 6Mm Dia Holes In M.S Angle Iron For Fixing Of Stables Etc. As Per Building Specification And Direction Of E / I. , Labour Cost Cutting Of M.S Angle Iron Posts To Required Length, One End Splitted As Fish Tailed In A Length Of 150Mm Complete As Per Building Sepcification And Direction Of E / I. , Supplying, Fitting And Fixing Straining Bolts With Nut Size 22Cm*10Mm Dia Tighten The Barbed Wire With Corner Post Complete As Per Building Specification And Direction Of E / I. , Supplying, Fitting And Fixing Galvanised Chain -Link Mess Having 3Mm Thick Wire Cell Type 40 X 40 Mm Fitted On M.S. Angle Frame With Two Diagonals Having 25X25x5mm Size Angle Including Cost Of Fabrication, Providing Necessary Bocking Arrangement With Haskal And Domny Duly Fixed In Angle Post, Applying A Priming Red Lead Paint Over Steel Work, Taxes Excluding The Cost Of Galvanised Chain-Link Mess All Complete. , Cost Of Galvanised Chain-Link Mess Having 3 Mm Thick Wire Cell Type 40X40 Mm Not Less Than 3.1 Kg / Sqm , Cost Of 50 X50 X6 Mm M.S Angle , Carriage Of Materials From Different Sources Or Departmental Stores To Work Site Including Loading, Transporting, Unloading And Stacking The Materials At Work Site Etc. All Complete Job. As Per Direction Of E / I. , Cement Lead 20 Km ( Avg. ) , Sand Lead 20 Km ( Avg. ) , Stone Chips Lead 20 Km ( Avg. ) , Steel Reinforcement Lead 20 Km ( Avg. ) , Annual Operation & Maintenance Cost Based On Existing D / T Well With Solarmotor Pump For 5 Years , O & M Cost For 1St Year ( Excluding Repair Charges ) , O & M Cost For 2Nd Year With Annual Repair Charges , O & M Cost For 3Rd Year , O & M Cost For 4Th Year , O & M Cost For 5Th Year , Provision Of One No Sim Card & Its Recharging Cost For Rmc , 12% Gst , Labour Cess
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 6
41.
Drinking Water Supply and Sanitation #8962446 Technical Bid
Construction Of Mini Rural Water Supply Scheme Solar Motor Pump Complete Set In Block Giridih Panchayat Senadoni Village Tigojori Svs Group Of Scheme Under Jjm D.W.S. Division, No 2 Giridih For The Year 2021-22 Group No Svs-06 , Model:- 1A, 1 No. , Village:- Tigojori , Tola:- Tigojori-Ii , Tube Well , Drilling Portion , Construction For 115 / 125 Mm Dia Drilled Tube-Well For Drilling In All Kinds Of Soil Rock For Installation Of Hand Pump With D.T.H Rig Machine All Complete Including Supplying All Materials, Labours, Tools, Drilling, Rigs, Air Compressor And Equipments As Well As Fuel Lubricant For Making 125 / 115 Mm Dia Boring Etcand Cost Of Transporting Rig Machine And Other Vehicle Up To Site Workas Per Specification And Direction Of Engineer-In-Charge. , ( A ) Up To 30Mtr. Depth Bellow G.L. In Rural Areas , ( B ) Beyond 30Mtr.In Rural Areas , Providing All Equipments And Labour For Lowering 125Mm Dia Blue Upvc Casing Pipe As Casing For Protecting The Side From Falling During The Process Of Drilling All Complete Job Including Carriage Of Material To Work Site. , Supplying Labour Cement And Calcium Chloride Or Bentonite Solution And Equipments For Grouting To Casing Pipe All Complete Job Including Carriage Of Material To Work Site As Per Specification & Direction Of E / I , Supplying All Tools, Equipments And Labour And Doing Washing, Flushing And Development Of Drilled Tube Well To Give Clean And Clear Water All Complete As Per Direction E / I. , Supplying All Materials Labours And Equipment Including 125 Mm Dia Gi / Ci Cap 125 Mm Dia T / W Properly All Complete And Taking It Out As Per Specification & Direction Of E / I. ( The Cap Will Be Property Of Department ) , Civil Portion , Supplying All Tools, Equipment, Labours And Lowering 32 Mm Dia G.I. ( Medium ) Pipe In Dt In 3 Mtr. Length All Complete Job As Per Direction Of E / I. Including Carriage Of Materials. , Supplying All Tools, Labour For Fitting And Fixing Deep Well Cylinder With Necessary Connecting Rod All Complete Job As Per Specification & Direction Of E / I. , Supplying All Materials, Labours For Fitting And Fixing Of India Mark Ii Hand Pump With All Accessories All Job Complete As Per Direction Of E / I. Including Carriage Of Materials. , Supplying All Materials, Labours And Equipment For Constructing Pcc ( 1:2:4 ) Circular Platform Around Each Drilled Tube Well Including 12Mm Thick Cement Plaster ( 1:4 ) With Neat Cement Punning Over Exposed Surface As Per Unicef Design Etc. All Complete. Including Carriage Of Materials. , Supplying All Materials Labour And Equipment For Constructing Pcc ( 1:2:4 ) Drain As Per Unicef Design Etc. All Complete .Including Carriage Of Materials. , Add Extra Item For Supplying Tools, Labours And Materials For Painting, Numbering And Year For Construction Of T / Well And Taking Of Colour Photograph With Two Or Three Nearest Persons Including Platform, Drain, Soak Pit And Also Longitude & Latitude, Details Of T / W Such As Total Depth, Casing Depth, Static Water Level, Drawdown, Discharge, Strata Chart, Beneficiary Population Etc In Separate Sheet / Format All Complete As Per Direction Of E / I. , Cost Of Materials , Cost Of Standard I.S.I. Mark Deep Well Hand Pump For India Mark-Ii, I.S.I. 15500 ( Part 2 ) / 2004 With Latest Revision Including 12Mm X 3 Meter Long 8 No. Connecting Rods Made Of Bright Bar Electro-Galvanized Fitted With Coupler & Normal Stand Assembly Recommended For Use With Cylinder Assembly Suitable For Bore Wellcasing Pipe. , Cost Of 32 Mm Dia Gi Pipe ( Medium ) 3 Mtrs Long Screwed At Both Ends With Seamless Socket As Per Is:1239 ( Part 1990 ) . , Cost Of 125 Mm Dia Blue Upvc Casing Pipe As Per I.S.12818 / 2016 Cml No.- 5543459 , Solar Photovoltaic ( Spv ) Solar Submersible D.C. Water Motor Pump , Designing, Supplying, Installation, Testing & Commissioning With All Tools & Parts Of Following Solar Photovoltaic ( Spv ) Solar Submersible D.C. Water Motor Pump Suitable For Minimum 125Mm X 115Mm Bore Well As Per Mnre Guideline With Following Specifications & Accessories. , Spv Arrays Contains Specified No Of Same Capacity Type & Specification Modules Connected To Series Or Parallel To Obtained The Required Voltage & Current The Power Output Of Individual Pvmodules Should Be Minimum 200 Watt Peak. , I ) The Spv Modules Should Be As Per Iec-61215 And Iec 61730 Part 1.0 ) , Ii ) All External Parts Of Motor Pump Used In Submersible Pump Which Are In Contact Of Water Is Stainless Steel Grade 303 Or Higher As Required. , Iii ) The Pv Modules Shouldbe Mounted On Metallic Structure Of Adequate Strength And Appropriate Design Which Can Withstand Load Of Modules & High Wind Pressure Up To 200Km / H. , Iv ) The Module Mounting Structure Should Be Hot Dip Galvanized According To Is 4759. , V ) To Enhance The Performance Of Spv Water Pumping System & Arrangement For Seasonal Tilt Angle Adjustment Should Be Provided , Vi ) Necessary Arrangement Should Be Provided In Controller Automatic Start-Run-Stop Through Out The Day With Water Level Detection System. ( As Per Mnre Specification ) , Vii ) Necessary Protection Such As Lightening Arrestor Etc. Should Be Provided To Protect The Controller & Spv , Viii ) The Suction / Delivery Pipe Shall Be Upvc / H.D.P.E. Pipes Of Appropriate Size 60M Or More As Required Minimum Pressure Rating Of 8Kg / Sq Cm- Pe 100 Grade For Pump Up To 3Hp & 10 Kg / Sq Cm- Pe 100 Grade For 5 Hp. , Ix ) All Cable Used Shall Be As Per Is 694. Suitable Size Of Cable Shall Be Used In Sufficient Length For Inter Connection Between The Spv Array To Spv Controller And Spv Controller To Solar Power Pump. Provision Of Cable Shall Be As Per Is 14536. , X ) The Motor Pump Set Should Have A 5 Years Warranty. , Xi ) Control Panel Suitable For Motor Pump With Arrangement Of Dry Run & Over Flow Protection Sensor, Float Switch & Rain Prevention Box. ( As Per Mnre Specification ) , Xii ) The Spv Controller Must Have Ip-65 Protection Or Must Be Housed In Cabinet Having At Least Ip-65 Protection. , Xiii ) The System Should Be As Per Mnre Guide Line & Eco-Friendly With Suitable Arrangement To Operate New Pump Manually. , Xiv ) With Third Party Inspection Before Dispatch. , Xv ) Fitting, Fixing & Mounting On Water Tank Steel Structure. , Xvi ) Provision For Web Basedremote Monitoring Of The Pumps To Be Installed Must Be Made Through The Inbuilt Controllers . It Should Be Possible To Ascertain The Daily Water Output, The Power Generated By Pv Array , The Up And Downtime Of The Pump During The Year, Number Of Days The Pump Was Unused Or Under Breakdown Repairs. , The Following Details Should Be Marked Indelibly On The Motor Pump Set , A ) Name Of The Manufacturer Or Distinctive Logo. , B ) Model Number. , C ) Serial Number. , Solar Submersible Motor Pump ( Spv Dc Type ) , I ) 1 Hp ( Dc Pump ) With 900 Wp Minimum Watt P.V. Panel As Mnre Pump Head Max Shut-Off Head Up To 120 Mtrs. For Higher Or Lower Head Or In Between Various Modules Output Could Be Decided On Prorates Basis. ( As Per Latest Guide Line Of Mnre ) , Carrying Out Recuperation / Yield Test For Ascertaining The Discharge Of Constructed Well / Excavated Profile As Directed By The Iec. The Testout By The Drawing Down Water From The Well / Profile Below Normal / Subsoil Water Level Up To Full Depth Rise Is Recorded The Normal Water Level / Subsoil Water Level In The Well / Profile As Well As Strainer / Level At Pump As Per Design Of W.S. Scheme Shall Be Recorded Prior To The Test Including Cost Of All Materials, Over Load , Labours Etc. Complete As Directed. , Supplying All Labours, Tools And Equipments For Dismantling Of Head & Water Tank Assembly And Taking Out 32 Mm Dia Old G.I. Pipe, Connecting Rod, Cylinder Assembly The Dismantled Components After Necessary Changing For Making The T / W In Good Condition With All Transportation Including Unused Taken Out Materials Back In Store All Complete Job As Per Direction Of E / I. ( As Per Model Estimate Of Solar Energy Based Mini Wss. Ts Done By Se, Ranchi Circle & Circle Gumla Dt. 21.05.2019 ) , Provision Of Solar Night Lamp. , Rcc Foundation For Steel Structurestaging& Solar Panel , Earth Work In Excavation In Foundation Trenches In Ordinary Soil And Disposal Of Excavated Earth As Obtained To A Distance Up To 50.0M , Including All Lifts, Levelling , Ramming The Foundation Trenches, Removing Roots Of Trees, Shrubs All Complete As Per Approved Design , Building Specification And Direction Of E / I ( Vide Classification Of Soil Item -B ) , Providing Coarse Clean Sand In Filling In Foundation Trenches Or In Plinth Including Ramming And Watering In Layers Not Exceeding 150Mm Thick With All Leads And Lifts Including Cost Of All Materials , Labour , Royalty And Taxes All Complete As Per Building Specification And Direction Of E / I ( Mode Of Measurement Compacted Volume ) , Providing Designation 75 A One Brick Flat Soling Joints Filled With Local Sand Including Cost Of Watering Taxes Royalty All Complete As Per Building Specification And Direction Of E / I , Providing Pcc M-150 In Nominal Mix Of ( 1:2:4 ) In Foundationwith Approved Quality Of Stone Chips 20Mm To 6Mm Size Graded And Clean Coarse Sand Of F.M.2.5To 3 Including Screening Shuttering Mixing Cement Concrete In Mixer And Placing In Position Vibrating Striking Curing And Royalty All Complete As Per Building Specification And Direction Of E / I , Providing Rcc M-200 In Nominal Mix Of ( 1:1.5:3 ) In Columnswith Approved Quality Of Stone Chips 20Mm To 6Mm Size Graded And Clean Coarse Sand Of F.M.2.5To 3 Including Screening Shuttering Mixing Cement Concrete In Mixer And Placing In Position Vibrating Striking Curing And Royalty All Complete As Per Building Specification And Direction Of E / I. ( Bcd-Sor ) Part- A 7.2 C Case 1 , ( A ) Foundation For Steel Structure Staging , Footing , Vertical Pedestal , Tie Beam , ( B ) Foundation For Solar Panel , Footing , Vertical Pedestal , Providing For Steel Reinforcement As Per Approved Design And Drawing Excluding Carriage Of T.S. Bar To Work Site Cutting, Bending With Annealed Wire With Cost Of Wire, Removal Of Rust Placing The Rods In Position All Complete As Per Building Specification And Direction Of E / I. , 10 Mm Dia , 12 Mm Dia , Carriage Of Materials From Different Sources Or Departmental Stores To Work Site Including Loading, Transporting, Unloading And Stacking The Materials At Work Site Etc. All Complete Job. As Per Direction Of E / I. , Cement Lead 20 Km ( Avg. ) , Sand Lead 20 Km ( Avg. ) , Stone Chips Lead 20 Km ( Avg. ) , Steel Reinforcement Lead 20 Km ( Avg. ) , Bricks Lead 20 Km ( Avg. ) , Galvanized Tubular Steel Structure Staging For ( 4.5M ) Hdpe Water Storage Tank& Solar Panel , Providing Structural Steel Galvanised Tubular Hollow Section Work In Trusses, Other Similar Trussed Purlins And Members With All Bracing , Gusset Plates Etc As Per Detailed Design And Drawing Or As Directed By Engineer- In-Charge , Including Cutting Fabricating , Hoisting , Erecting And Fixing In Position , Making Riveted / Bolted / Welded Connections And One Coat Of Anticorrosive Paint And Over It Two Coat Of All Oil Painting & For Structure ( Plus ) Providing And Applying Materials &Labour For Hot Dip Galvanizing Of Above Structure Including Transportation For Galvanizing Minimum Thickness 80Microns ( Net Wt. Of Components To Be Galv ) Preferably Tata Structural Section Etc Complete. , Providing Structural Steel Work In Trusses Other Similar Trussed Purlins And Members With Bracing Gusset Plates Etc As Per Detailed Design And Drawing Or As Directed By Engineer- In-Charge Including Cutting Fabricating Hoisting Erecting And Fixing In Position Making Reverted Bolted Welded Connections One Coat Of Anticorrosive Paint And Over It Two Coats Of Oil Painting Etc Complete ( Mjp 2019-2020 Sec F Item 6 ) , Materials And Labour For Vinyl Painting Of Matter Given By Department In Different Color ( As Per Market Rate ) , Installation Of 2000 Liters Capacity Water Storage Tank , Providing And Fixing Hdpe Container Syntex Or Alike One Piecemolded Water Tank Made Out Of Low Density Polythyler Andbuilt Corrugation Including Of Delivery Up To Destination Hoisting And Fixing Of Accessories Such As Inlet, Outlet Overflow Of All Tanks Capacity 2000.00 Litres Capacity Water Storage Tank ( Dwsd Item No-01 M ) , Transportation Charge , Lifting Of 2000 Litrs Capacity Tank Up To 4.5M Height With Lifting Tools With Rope And Labour , Making Hole In Tank , Making Long Screw In G.I. Pipe Including Supplying And Fitting Jam Nuts And Extra Socket Etc. , Rising And Distribution Network With House Connection Up To 10 Nos. Including Platform & Stand Post , Earth Work In Excavation In Foundation Trenches In Hard Soil ( Vide Classification Soil Item B ) And Disposal Of Excavated Earth As Obtained To A Distance Up To 50 Mtr. Including All Lifts, Leveling, Ramming The Foundation Trenches, Removing Roots Of Trees, Shrubs All Complete As Per Approved Design, Specification And Direction Of E / I. , Dismantling Plain Cement Concrete Work Including Stacking Serviceable Materials In Countable Stacks Within 15 M Lead And Disposal Of Unserviceable Materials With All Leads All Complete. , Providing Pccm-200 With Nominal Mix Of ( 1:1.5:3 ) With Approved Quality Of Stone Chips 20 Mm To 6 Mm Size Graded And Clean Coarse Sand Of Fm 2.5 To 3.0 Including Screening, Shuttering, Mixing Cement Concrete In Mixer And Placing In Position, Vibrating, Sticking, Curing , Taxes And Royalty All Complete As Per Specification And Direction Of E / I. For Construction Of Road Cutting Portion. , Rising Main , Manufacture, Supply And Delivery Offollowing Nominal Dia Upvc Column Pipes Including Pvc Socket ( Coupler ) , , 65Mm Dia -Density Of Pipe 1.38 To 1.43 Gm Per Cm3 Od:74.5 To 75.2Mm Wall Thickness End:9Mm To 10.7Mm, Barrel 9Mm To 10.7 Mm, Length: 3Mtrs.Rising Main , 50 Mm Dia -Density Of Pipe 1.38 To 1.43 Gm Per Cm3 Od:87.5 To 88.2Mm Wall Thickness End:9 .8 Mm To 11.9Mm, Barrel 7.3Mm To 9 Mm, Length: 3Mtrs. Delivery Pipe , Distribution Main , Providing And Supplying High Density Polyethylene Pipe ( Hdpe Pipe ) Of 20 Mm To 225 Mm Od And Pressure 6.0 Kg / Cm2 And 10 Kg / Cm2 Suitable For Water Supply Which Is Available In All Standard Conforming To Isi -- 4984 / 14151 / 12786 / 13488, Iso 4427 , Din-8074Materials Rates Are Ex-Factory Excluding Transportation, Taxes And Duties. Pe-80 , Pn- 10. , 63 Mm Hdpe Pipe , 50 Mm Hdpe Pipe , 32 Mm Hdpe Pipe- , 20 Mm Hdpe Pipe- , Providing And Fixing Gun Metal Gate Valvewith C I Wheel Of Approved Quality ( Screwed End ) . , 65Mm Dia , 50 Mm Dia . , Providing And Supplying High Density Polyethylene ( Hdpe ) Fittings Of 20 Mm To 225 Mm Od And Pressure 6.0 Kg / Cm2 And 10 Kg / Cm2 Suitable For Water Supply Which Is Available In All Standard Conforming To Isi -- 4984 / 14151 / 12786 / 13488, Iso 4427 , Din-8074Materials Rates Are Ex-Factory Excluding Transportation, Taxes And Duties. , Lowering, Laying And Jointing H. D. P. E. / M. D.P. E. Pipes In Proper Position Including All Specials By Compression Fitting / Electro Fusion And Butt Fusion Jointing Procedure As Per Relevant Is Code Complete With All Materials For Jointing Procedure Like Electro Fusion Machine, Electric Heater / Butt Fusion Welding Machine With Hydraulic Jack, Top Loading Clamp Etc. And All Labours As Directed By Engineer In Charge As Per Is-7634 Part Ii. , For Rising , 65 Mm Hdpe Pipe , 50 Mm Hdpe Pipe , For Distribution , 65 Mm Hdpe Pipe , 50 Mm Hdpe Pipe , 32 Mm Hdpe Pipe , 20 Mm Hdpe Pipe , Providing 15 Mm Dia. G.I. Pipe Tata Or Equivalent Make As Per Is 1239 ( Part 1 / 2004 ) Isi Mark / Medium Quality In Stand Post. , Supplying All Materials , Labour And Tools For Fixing 15 Mm Dia G.I. Pipes With Red Lead And Yarn Of Following Nominal Bore With Screwed And Socketed Joints On Wall, Ceiling And Floor Including Supplying And Fitting Of Wall Hooks Or Pipe Clamps, Wooden Plugs, Cutting Pipes To Size And Threading Ends If Required Etc. All Complete As Per Specification And Direction Of Engineer-In-Charge. , Supplying And Fixing G.I. Fittings Of Approved Make All Complete As Per Specification And Direction Of E / I. , Elbow 15 Mm Dia. , Reducer Socket 20X15 Mm Dia. , Nipple 15 Mm Dia. , Plain Socket 15 Mm Dia. , Supplying And Fixing G.M. Ferrule Of Approved Make In Existing C.I. / D.I. Main Including Drilling And Taping C.I. / D.I. Main All Complete As Per Specification And Direction Of E / I. 3 Mm, 6 Mm 10 Mm Dm Ferrule Weight Not Less Than 425 Gram. , Providing And Fixing Gun Metal Full Way Valve Of Approved Quality, All Complete, As Per Specification And Direction Of E / I. , 65 Mm Dia Full Way Valve , 50 Mm Dia And Weight Not Less Than 1.5 Kg. , Providing And Fixing Of Male Ended C.I.Body Brass Spindle Valve And Seat Bib Cock Of Approved Quality With Extra Socketall Complete As Per Specification And Direction Of E / I. , 15 Dia And Weight Not Less Than 400 Gm , Constructing Masonry Chamber 30X30x50 Cm Inside, In Brick Work In Cement Mortar 1:4 ( 1 Cement :4 Coarse Sand ) For Stop Cock, With C. I. Surface Box 100X100 X75 Mm ( Inside ) With Hinged Cover Fixed In Cement Concrete Slab 1:2:4 Mix ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size ) , I / C Necessary Excavation, Foundation Concrete 1:5:10 ( 1 Cement : 5 Fine Sand : 10 Graded Stone Aggregate 40Mm Nominal Size ) And Inside Plastering With Cement Mortar 1:3 ( 1 Cement : 3 Coarse Sand ) 12Mm Thick, Finished With A Floating Coat Of Neat Cement Complete As Per Standard Design.With Common Burnt Clay F.P.S. ( Non Modular ) Bricks Of Class Designation 7.5. , Full Way Valve Chamber , Supplying Materials , Labours And Equipments For Construction Of 0.90M X 0.90 M Size P.C.C. ( 1:2:4 ) Rectangular Platform With Stand Post In House Including 12 Mm Thick Cement Plaster In C.M. ( 1:4 ) With Neat Cement Punning Over Exposed Surfaceall Complete Job, As Per Approved Design, Specification And Direction Of E / I. , Providing Brick Masonry Chamber Ofinner Size 600 X 600 X 450 Mm Deep For Bore Well Protection Having 125 Mm Thick Wall And 75 Mm R.C.C Cover Including Cement Plaster Of Exposed Surface, Etc All Complete Job. , Earth Work In Back Filling The Trenches After Laying Different Types And Size Of Pipes With Earth Removed During Excavation Within Initial Lead And Lift As Per Specification And Direction Of Engineer-In-Charge. , Providing Fitting & Fixing 32 Mm To 50 Mm Service Hdpe Saddleall Complete Job, As Per Approved Design, Specification And Direction Of E / I. , Annual Operation & Maintenance Cost Based On Existing D / T Well With Solarmotor Pump For 5 Years , O & M Cost For 1St Year ( Excluding Repair Charges ) , O & M Cost For 2Nd Year With Annual Repair Charges , O & M Cost For 3Rd Year , O & M Cost For 4Th Year , O & M Cost For 5Th Year , Provision Of One No Sim Card & Its Recharging Cost For Rmc , Model:- 1B, 1 No. , Village:- Tigojori , Tola:- Tigojori-I , Tube Well , Drilling Portion , Construction For 115 / 125 Mm Dia Drilled Tube-Well For Drilling In All Kinds Of Soil Rock For Installation Of Hand Pump With D.T.H Rig Machine All Complete Including Supplying All Materials, Labours, Tools, Drilling, Rigs, Air Compressor And Equipments As Well As Fuel Lubricant For Making 125 / 115 Mm Dia Boring Etcand Cost Of Transporting Rig Machine And Other Vehicle Up To Site Workas Per Specification And Direction Of Engineer-In-Charge. , ( A ) Up To 30Mtr. Depth Bellow G.L. In Rural Areas , ( B ) Beyond 30Mtr.In Rural Areas , Providing All Equipments And Labour For Lowering 125Mm Dia Blue Upvc Casing Pipe As Casing For Protecting The Side From Falling During The Process Of Drilling All Complete Job Including Carriage Of Material To Work Site. , Supplying Labour Cement And Calcium Chloride Or Bentonite Solution And Equipments For Grouting To Casing Pipe All Complete Job Including Carriage Of Material To Work Site As Per Specification & Direction Of E / I , Supplying All Tools, Equipments And Labour And Doing Washing, Flushing And Development Of Drilled Tube Well To Give Clean And Clear Water All Complete As Per Direction E / I. , Supplying All Materials Labours And Equipment Including 125 Mm Dia Gi / Ci Cap 125 Mm Dia T / W Properly All Complete And Taking It Out As Per Specification & Direction Of E / I. ( The Cap Will Be Property Of Department ) , Civil Portion , Supplying All Tools, Equipment, Labours And Lowering 32 Mm Dia G.I. ( Medium ) Pipe In Dt In 3 Mtr. Length All Complete Job As Per Direction Of E / I. Including Carriage Of Materials. , Supplying All Tools, Labour For Fitting And Fixing Deep Well Cylinder With Necessary Connecting Rod All Complete Job As Per Specification & Direction Of E / I. , Supplying All Materials, Labours For Fitting And Fixing Of India Mark Ii Hand Pump With All Accessories All Job Complete As Per Direction Of E / I. Including Carriage Of Materials. , Supplying All Materials, Labours And Equipment For Constructing Pcc ( 1:2:4 ) Circular Platform Around Each Drilled Tube Well Including 12Mm Thick Cement Plaster ( 1:4 ) With Neat Cement Punning Over Exposed Surface As Per Unicef Design Etc. All Complete. Including Carriage Of Materials. , Supplying All Materials Labour And Equipment For Constructing Pcc ( 1:2:4 ) Drain As Per Unicef Design Etc. All Complete .Including Carriage Of Materials. , Add Extra Item For Supplying Tools, Labours And Materials For Painting, Numbering And Year For Construction Of T / Well And Taking Of Colour Photograph With Two Or Three Nearest Persons Including Platform, Drain, Soak Pit And Also Longitude & Latitude, Details Of T / W Such As Total Depth, Casing Depth, Static Water Level, Drawdown, Discharge, Strata Chart, Beneficiary Population Etc In Separate Sheet / Format All Complete As Per Direction Of E / I. , Cost Of Materials , Cost Of Standard I.S.I. Mark Deep Well Hand Pump For India Mark-Ii, I.S.I. 15500 ( Part 2 ) / 2004 With Latest Revision Including 12Mm X 3 Meter Long 8 No. Connecting Rods Made Of Bright Bar Electro-Galvanized Fitted With Coupler & Normal Stand Assembly Recommended For Use With Cylinder Assembly Suitable For Bore Wellcasing Pipe. , Cost Of 32 Mm Dia Gi Pipe ( Medium ) 3 Mtrs Long Screwed At Both Ends With Seamless Socket As Per Is:1239 ( Part 1990 ) . , Cost Of 125 Mm Dia Blue Upvc Casing Pipe As Per I.S.12818 / 2016 Cml No.- 5543459 , Rcc Foundation For Steel Structurestaging& Solar Panel , Earth Work In Excavation In Foundation Trenches In Ordinary Soil And Disposal Of Excavated Earth As Obtained To A Distance Up To 50.0M , Including All Lifts, Levelling , Ramming The Foundation Trenches, Removing Roots Of Trees, Shrubs All Complete As Per Approved Design , Building Specification And Direction Of E / I ( Vide Classification Of Soil Item -B ) , Providing Coarse Clean Sand In Filling In Foundation Trenches Or In Plinth Including Ramming And Watering In Layers Not Exceeding 150Mm Thick With All Leads And Lifts Including Cost Of All Materials , Labour , Royalty And Taxes All Complete As Per Building Specification And Direction Of E / I , Providing Designation 75 A One Brick Flat Soling Joints Filled With Local Sand Including Cost Of Watering Taxes Royalty All Complete As Per Building Specification And Direction Of E / I , Providing Nominal Mix Pcc Of ( 1:4:8 ) In Foundationwith Approved Quality Of Stone Chips 20Mm To 6Mm Size Graded And Clean Coarse Sand Of F.M.2.5To 3 Including Screening Shuttering Mixing Cement Concrete In Mixer And Placing In Position Vibrating Striking Curing And Royalty All Complete As Per Building Specification And Direction Of E / I , Providing Rcc M-20 In Nominal Mix Of ( 1:1.5:3 ) In Columnswith Approved Quality Of Stone Chips 20Mm To 6Mm Size Graded And Clean Coarse Sand Of F.M.2.5To 3 Including Screening Shuttering Mixing Cement Concrete In Mixer And Placing In Position Vibrating Striking Curing And Royalty All Complete As Per Building Specification And Direction Of E / I. , ( A ) Foundation For Steel Structure Staging , Footing And Vertical Pedestal Raft , Column , Tie Beam , ( B ) Foundation For Solar Panel , Footing , Vertical Pedestal , Providing For Steel Reinforcement As Per Approved Design And Drawing Excluding Carriage Of T.S. Bar To Work Site Cutting, Bending With Annealed Wire With Cost Of Wire, Removal Of Rust Placing The Rods In Position All Complete As Per Building Specification And Direction Of E / I. , ( A ) Foundation For Steel Structure Staging , Carriage Of Materials From Different Sources Or Departmental Stores To Work Site Including Loading, Transporting, Unloading And Stacking The Materials At Work Site Etc. All Complete Job. As Per Direction Of E / I. , Cement Lead 20 Km ( Avg. ) , Sand Lead 20 Km ( Avg. ) , Stone Chips Lead 20 Km ( Avg. ) , Steel Reinforcement Lead 20 Km ( Avg. ) , Bricks Lead 20 Km ( Avg. ) , Galvanized Tubular Steel Structure Staging Forhdpe Water Storage Tank& Solar Panel , Providing Structural Steel Galvanisedsqure Pipe Section Work In Trusses, Other Similar Trussed Purlins And Members With All Bracing , Gusset Plates Etc As Per Detailed Design And Drawing Or As Directed By Engineer- In-Charge , Including Cutting Fabricating , Hoisting , Erecting And Fixing In Position , Making Riveted / Bolted / Welded Connections And One Coat Of Anticorrosive Paint And Over It Two Coat Of All Oil Painting & For Structure ( Plus ) Providing And Applying Materials &Labour For Hot Dip Galvanizing Of Above Structure Including Transportation For Galvanizing Minimum Thickness 80Microns ( Net Wt. Of Components To Be Galv ) Preferably Tata Structural Section Etc Complete. , Hardware ( L.S. ) , Information Board For Iec , Installation Of 5000 Liters Capacity Water Storage Tank , Providing And Fixing Hdpe Container Syntex Or Alike One Piecemolded Water Tank Made Out Of Low Density Polythyler Andbuilt Corrugation Including Of Delivery Up To Destination Hoisting And Fixing Of Accessories Such As Inlet, Outlet Overflow Of All Tanks Capacity 5000.00 Litres Capacity Water Storage Tank , Transportation Charge , Lifting Of 5000 Litrs Capacity Tank Up To 4.00M Height With Lifting Tools With Rope And Labour , Making Hole In Tank , Making Long Screw In G.I. Pipe Including Supplying And Fitting Jam Nuts And Extra Socket Etc. , Rising And Distribution Network With House Connection Up To 20 Nos. Including Platform & Stand Post , Earth Work In Excavation In Foundation Trenches In Hard Soil ( Vide Classification Soil Item B ) And Disposal Of Excavated Earth As Obtained To A Distance Up To 50 Mtr. Including All Lifts, Leveling, Ramming The Foundation Trenches, Removing Roots Of Trees, Shrubs All Complete As Per Approved Design, Specification And Direction Of E / I. , Dismantling Plain Cement Concrete Work Including Stacking Serviceable Materials In Countable Stacks Within 15 M Lead And Disposal Of Unserviceable Materials With All Leads All Complete , Providing Pccm-200 With Nominal Mix Of ( 1:1.5:3 ) With Approved Quality Of Stone Chips 20 Mm To 6 Mm Size Graded And Clean Coarse Sand Of Fm 2.5 To 3.0 Including Screening, Shuttering, Mixing Cement Concrete In Mixer And Placing In Position, Vibrating, Sticking, Curing , Taxes And Royalty All Complete As Per Specification And Direction Of E / I. For Construction Of Road Cutting Portion , Rising Main , Manufacture, Supply And Delivery Offollowing Nominal Dia Upvc Column Pipes Including Pvc Socket ( Coupler ) , , 65Mm Dia -Density Of Pipe 1.38 To 1.43 Gm Per Cm3 Od:74.5 To 75.2Mm Wall Thickness End:9Mm To 10.7Mm, Barrel 9Mm To 10.7 Mm, Length: 3Mtrs.Rising Main , 50 Mm Dia -Density Of Pipe 1.38 To 1.43 Gm Per Cm3 Od:87.5 To 88.2Mm Wall Thickness End:9 .8 Mm To 11.9Mm, Barrel 7.3Mm To 9 Mm, Length: 3Mtrs. Delivery Pipe , Distribution , Providing And Supplying High Density Polyethylene Pipe ( Hdpe Pipe ) Of 20 Mm To 225 Mm Od And Pressure 6.0 Kg / Cm2 And 10 Kg / Cm2 Suitable For Water Supply Which Is Available In All Standard Conforming To Isi -- 4984 / 14151 / 12786 / 13488, Iso 4427 , Din-8074Materials Rates Are Ex-Factory Excluding Transportation, Taxes And Duties. , 63 Mm Hdpe Pipe , 50 Mm Hdpe Pipe , 32 Mm Hdpe Pipe , 20 Mm Hdpe Pipe , Providing And Fixing Gun Metal Gate Valvewith C I Wheel Of Approved Quality ( Screwed End ) . , 65Mm Dia , 50Mm Dia , Providing And Supplying High Density Polyethylene ( Hdpe ) Fittings Of 20 Mm To 225 Mm Od And Pressure 6.0 Kg / Cm2 And 10 Kg / Cm2 Suitable For Water Supply Which Is Available In All Standard Conforming To Isi -- 4984 / 14151 / 12786 / 13488, Iso 4427 , Din-8074Materials Rates Are Ex-Factory Excluding Transportation, Taxes And Duties. , Lowering, Laying And Jointing H. D. P. E. / M. D.P. E. Pipes In Proper Position Including All Specials By Compression Fitting / Electro Fusion And Butt Fusion Jointing Procedure As Per Relevant Is Code Complete With All Materials For Jointing Procedure Like Electro Fusion Machine, Electric Heater / Butt Fusion Welding Machine With Hydraulic Jack, Top Loading Clamp Etc. And All Labours As Directed By Engineer In Charge As Per Is-7634 Part Ii. , For Rising , 65 Mm Hdpe Pipe , 50 Mm Hdpe Pipe , Distribution , 65 Mm Hdpe Pipe , 50 Mm Hdpe Pipe , 32 Mm Hdpe Pipe , 20 Mm Hdpe Pipe , Providing 15 Mm Dia. G.I. Pipe Tata Or Equivalent Make As Per Is 1239 ( Part 1 / 2004 ) Isi Mark / Medium Quality In Stand Post. , Supplying All Materials , Labour And Tools For Fixing 15 Mm Dia G.I. Pipes With Red Lead And Yarn Of Following Nominal Bore With Screwed And Socketed Joints On Wall, Ceiling And Floor Including Supplying And Fitting Of Wall Hooks Or Pipe Clamps, Wooden Plugs, Cutting Pipes To Size And Threading Ends If Required Etc. All Complete As Per Specification And Direction Of Engineer-In-Charge. , Supplying And Fixing G.I. Fittings Of Approved Make All Complete As Per Specification And Direction Of E / I. , Elbow 15 Mm Dia. , Reducer Socket 20X15 Mm Dia. , Nipple 15 Mm Dia. , Plain Socket 15 Mm Dia. , Supplying And Fixing G.M. Ferrule Of Approved Make In Existing C.I. / D.I. Main Including Drilling And Taping C.I. / D.I. Main All Complete As Per Specification And Direction Of E / I. 3 Mm, 6 Mm 10 Mm Dm Ferrule Weight Not Less Than 425 Gram. , Providing And Fixing Gun Metal Full Way Valve Of Approved Quality, All Complete, As Per Specification And Direction Of E / I. , 65 Mm Dia Full Way Valve , 50 Mm Dia And Weight Not Less Than 1.5 Kg. , Providing And Fixing Of Male Ended C.I.Body Brass Spindle Valve And Seat Bib Cock Of Approved Quality With Extra Socketall Complete As Per Specification And Direction Of E / I. , 15 Dia And Weight Not Less Than 400 Gm , Constructing Masonry Chamber 30X30x50 Cm Inside, In Brick Work In Cement Mortar 1:4 ( 1 Cement :4 Coarse Sand ) For Stop Cock, With C. I. Surface Box 100X100 X75 Mm ( Inside ) With Hinged Cover Fixed In Cement Concrete Slab 1:2:4 Mix ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size ) , I / C Necessary Excavation, Foundation Concrete 1:5:10 ( 1 Cement : 5 Fine Sand : 10 Graded Stone Aggregate 40Mm Nominal Size ) And Inside Plastering With Cement Mortar 1:3 ( 1 Cement : 3 Coarse Sand ) 12Mm Thick, Finished With A Floating Coat Of Neat Cement Complete As Per Standard Design.With Common Burnt Clay F.P.S. ( Non Modular ) Bricks Of Class Designation 7.5. Full Way Valve Chamber , Supplying Materials , Labours And Equipments For Construction Of 0.90M X 0.90 M Size P.C.C. ( 1:2:4 ) Rectangular Platform With Stand Post In House Including 12 Mm Thick Cement Plaster In C.M. ( 1:4 ) With Neat Cement Punning Over Exposed Surfaceall Complete Job, As Per Approved Design, Specification And Direction Of E / I. , Providing Brick Masonry Chamber Ofinner Size 600 X 600 X 450 Mm Deep For Bore Well Protection Having 125 Mm Thick Wall And 75 Mm R.C.C Cover Including Cement Plaster Of Exposed Surface, Etc All Complete Job , Earth Work In Back Filling The Trenches After Laying Different Types And Size Of Pipes With Earth Removed During Excavation Within Initial Lead And Lift As Per Specification And Direction Of Engineer-In-Charge. , Providing Fitting & Fixing 32 Mm To 50 Mm Service Hdpe Saddleall Complete Job, As Per Approved Design, Specification And Direction Of E / I. , Solar Photovoltaic ( Spv ) Solar Submersible D.C. Water Motor Pump , Designing, Supplying, Installation, Testing & Commissioning With All Tools & Parts Of Following Solar Photovoltaic ( Spv ) Solar Submersible D.C. Water Motor Pump Suitable For Minimum 125Mm X 115Mm Bore Well As Per Mnre Guideline With Following Specifications & Accessories. , Spv Arrays Contains Specified No Of Same Capacity Type & Specification Modules Connected To Series Or Parallel To Obtained The Required Voltage & Current The Power Output Of Individual Pvmodules Should Be Minimum 200 Watt Peak. , I ) The Spv Modules Should Be As Per Iec-61215 And Iec 61730 Part 1.0 ) , Ii ) All External Parts Of Motor Pump Used In Submersible Pump Which Are In Contact Of Water Is Stainless Steel Grade 303 Or Higher As Required. , Iii ) The Pv Modules Shouldbe Mounted On Metallic Structure Of Adequate Strength And Appropriate Design Which Can Withstand Load Of Modules & High Wind Pressure Up To 200Km / H. , Iv ) The Module Mounting Structure Should Be Hot Dip Galvanized According To Is 4759. , V ) To Enhance The Performance Of Spv Water Pumping System & Arrangement For Seasonal Tilt Angle Adjustment Should Be Provided , Vi ) Necessary Arrangement Should Be Provided In Controller Automatic Start-Run-Stop Through Out The Day With Water Level Detection System. ( As Per Mnre Specification ) , Vii ) Necessary Protection Such As Lightening Arrestor Etc. Should Be Provided To Protect The Controller & Spv , Viii ) The Suction / Delivery Pipe Shall Be Upvc / H.D.P.E. Pipes Of Appropriate Size 60M Or More As Required Minimum Pressure Rating Of 8Kg / Sq Cm- Pe 100 Grade For Pump Up To 3Hp & 10 Kg / Sq Cm- Pe 100 Grade For 5 Hp. , Ix ) All Cable Used Shall Be As Per Is 694. Suitable Size Of Cable Shall Be Used In Sufficient Length For Inter Connection Between The Spv Array To Spv Controller And Spv Controller To Solar Power Pump. Provision Of Cable Shall Be As Per Is 14536. , X ) The Motor Pump Set Should Have A 5 Years Warranty. , Xi ) Control Panel Suitable For Motor Pump With Arrangement Of Dry Run & Over Flow Protection Sensor, Float Switch & Rain Prevention Box. ( As Per Mnre Specification ) , Xii ) The Spv Controller Must Have Ip-65 Protection Or Must Be Housed In Cabinet Having At Least Ip-65 Protection. , Xiii ) The System Should Be As Per Mnre Guide Line & Eco-Friendly With Suitable Arrangement To Operate New Pump Manually. , Xiv ) With Third Party Inspection Before Dispatch. , Xv ) Provision For Web Basedremote Monitoring Of The Pumps To Be Installed Must Be Made Through The Inbuilt Controllers . It Should Be Possible To Ascertain The Daily Water Output, The Power Generated By Pv Array , The Up And Downtime Of The Pump During The Year, Number Of Days The Pump Was Unused Or Under Breakdown Repairs. , The Following Details Should Be Marked Indelibly On The Motor Pump Set , A ) Name Of The Manufacturer Or Distinctive Logo. , B ) Model Number. , C ) Serial Number. , Solar Submersible Motor Pump ( Spv Dc Type ) , I ) 1 Hp ( Dc Pump ) With 900 Wp Minimum Watt P.V. Panel As Mnre Pump Head Max Shut-Off Head Up To 120 Mtrs. For Higher Or Lower Head Or In Between Various Modules Output Could Be Decided On Prorates Basis. ( As Per Latest Guide Line Of Mnre ) , Carrying Out Recuperation / Yield Test For Ascertaining The Discharge Of Constructed Well / Excavated Profile As Directed By The Iec. The Testout By The Drawing Down Water From The Well / Profile Below Normal / Subsoil Water Level Up To Full Depth Rise Is Recorded The Normal Water Level / Subsoil Water Level In The Well / Profile As Well As Strainer / Level At Pump As Per Design Of W.S. Scheme Shall Be Recorded Prior To The Test Including Cost Of All Materials, Over Load , Labours Etc. Complete As Directed. , Supplying All Labours, Tools And Equipments For Dismantling Of Head & Water Tank Assembly And Taking Out 32 Mm Dia Old G.I. Pipe, Connecting Rod, Cylinder Assembly The Dismantled Components After Necessary Changing For Making The T / W In Good Condition With All Transportation Including Unused Taken Out Materials Back In Store All Complete Job As Per Direction Of E / I. ( As Per Model Estimate Of Solar Energy Based Mini Wss. Ts Done By Se, Ranchi Circle & Circle Gumla Dt. 21.05.2019 ) , Provision Of Solar Night Lamp. , Galvanised Chain-Line Mess Fencing Around Solar Panel Where Bore Well Is Away From Tower , Making 30 Cm ( 12 ) Dia Bore Up To 4M Below Ground With Hand Auger Of Approved Quality In Ordinary Soil ( Vide Classification Of Soil Item-A ) True To Plum And Without Eccentricity In Any Stage Of Operation And Disposal Of The Exacavated Earth Up To 50M Lead Including All Lifts All Complete As Per Approved Design And Direction Of E / I. , Providing Pcc M-150 In Nominal Mix Of ( 1:2:4 ) In Foundationwith Approved Quality Of Stone Chips 20Mm To 6Mm Size Graded And Clean Coarse Sand Of F.M.2.5 To 3 Including Screening Shuttering, Mixing Cement Concrete In Mixer And Placing In Position, Vibrating, Curing, Taxes And Royalty All Complete As Per Building Specification Direction Of E / I. , Labour Cost Of Fitting And Fixing Galvanised Chain-Link Mess Up Height Of 2 M Including Cost Of Staples ( But Excluding The Cost Of Cement Concete Angle Iron Posts, Its Cutting And Making Holes, Nuts And Bolts ) All Complete As Per Specification And Direction Of E / I. , Drilling 6Mm Dia Holes In M.S Angle Iron For Fixing Of Stables Etc. As Per Building Specification And Direction Of E / I. , Labour Cost Cutting Of M.S Angle Iron Posts To Required Length, One End Splitted As Fish Tailed In A Length Of 150Mm Complete As Per Building Sepcification And Direction Of E / I. , Supplying, Fitting And Fixing Straining Bolts With Nut Size 22Cm*10Mm Dia Tighten The Barbed Wire With Corner Post Complete As Per Building Specification And Direction Of E / I. , Supplying, Fitting And Fixing Galvanised Chain -Link Mess Having 3Mm Thick Wire Cell Type 40 X 40 Mm Fitted On M.S. Angle Frame With Two Diagonals Having 25X25x5mm Size Angle Including Cost Of Fabrication, Providing Necessary Bocking Arrangement With Haskal And Domny Duly Fixed In Angle Post, Applying A Priming Red Lead Paint Over Steel Work, Taxes Excluding The Cost Of Galvanised Chain-Link Mess All Complete. , Cost Of Galvanised Chain-Link Mess Having 3 Mm Thick Wire Cell Type 40X40 Mm Not Less Than 3.1 Kg / Sqm , Cost Of 50 X50 X6 Mm M.S Angle , Carriage Of Materials From Different Sources Or Departmental Stores To Work Site Including Loading, Transporting, Unloading And Stacking The Materials At Work Site Etc. All Complete Job. As Per Direction Of E / I. , Cement Lead 20 Km ( Avg. ) , Sand Lead 20 Km ( Avg. ) , Stone Chips Lead 20 Km ( Avg. ) , Steel Reinforcement Lead 20 Km ( Avg. ) , Annual Operation & Maintenance Cost Based On Existing D / T Well With Solarmotor Pump For 5 Years , O & M Cost For 1St Year ( Excluding Repair Charges ) , O & M Cost For 2Nd Year With Annual Repair Charges , O & M Cost For 3Rd Year , O & M Cost For 4Th Year , O & M Cost For 5Th Year , Provision Of One No Sim Card & Its Recharging Cost For Rmc , 12% Gst , Labour Cess
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
42.
Drinking Water Supply and Sanitation #8962442 Technical Bid
Construction Of Mini Rural Water Supply Scheme Solar Motor Pump Complete Set In Block Rajdhanwar Panchayat Balhara Village Karmatand Svs Group Of Scheme Under Jjm D.W.S. Division, No 2 Giridih For The Year 2021-22 Group No Svs-11 Construction Of Mini Rural Water Supply Scheme Solar Motor Pump Complete Set In Block Rajdhanwar Panchayat Balhara Village Karmatand Svs Group Of Scheme Under Jjm D.W.S. Division, No 2 Giridih For The Year 2021-22 Group No Svs-11 , Model:- 1B, 8 Nos. , Village:- Karmatand , Tola:-Churkibar-I & Ii, Dhalwa More-I, Ii & Iii, Rohaniya Tand-I, Ii & Iii , Tube Well , Drilling Portion , Construction For 115 / 125 Mm Dia Drilled Tube-Well For Drilling In All Kinds Of Soil Rock For Installation Of Hand Pump With D.T.H Rig Machine All Complete Including Supplying All Materials, Labours, Tools, Drilling, Rigs, Air Compressor And Equipments As Well As Fuel Lubricant For Making 125 / 115 Mm Dia Boring Etcand Cost Of Transporting Rig Machine And Other Vehicle Up To Site Workas Per Specification And Direction Of Engineer-In-Charge. , ( A ) Up To 30Mtr. Depth Bellow G.L. In Rural Areas , ( B ) Beyond 30Mtr.In Rural Areas , Providing All Equipments And Labour For Lowering 125Mm Dia Blue Upvc Casing Pipe As Casing For Protecting The Side From Falling During The Process Of Drilling All Complete Job Including Carriage Of Material To Work Site. , Supplying Labour Cement And Calcium Chloride Or Bentonite Solution And Equipments For Grouting To Casing Pipe All Complete Job Including Carriage Of Material To Work Site As Per Specification & Direction Of E / I , Supplying All Tools, Equipments And Labour And Doing Washing, Flushing And Development Of Drilled Tube Well To Give Clean And Clear Water All Complete As Per Direction E / I. , Supplying All Materials Labours And Equipment Including 125 Mm Dia Gi / Ci Cap 125 Mm Dia T / W Properly All Complete And Taking It Out As Per Specification & Direction Of E / I. ( The Cap Will Be Property Of Department ) , Civil Portion , Supplying All Tools, Equipment, Labours And Lowering 32 Mm Dia G.I. ( Medium ) Pipe In Dt In 3 Mtr. Length All Complete Job As Per Direction Of E / I. Including Carriage Of Materials. , Supplying All Tools, Labour For Fitting And Fixing Deep Well Cylinder With Necessary Connecting Rod All Complete Job As Per Specification & Direction Of E / I. , Supplying All Materials, Labours For Fitting And Fixing Of India Mark Ii Hand Pump With All Accessories All Job Complete As Per Direction Of E / I. Including Carriage Of Materials. , Supplying All Materials, Labours And Equipment For Constructing Pcc ( 1:2:4 ) Circular Platform Around Each Drilled Tube Well Including 12Mm Thick Cement Plaster ( 1:4 ) With Neat Cement Punning Over Exposed Surface As Per Unicef Design Etc. All Complete. Including Carriage Of Materials. , Supplying All Materials Labour And Equipment For Constructing Pcc ( 1:2:4 ) Drain As Per Unicef Design Etc. All Complete .Including Carriage Of Materials. , Add Extra Item For Supplying Tools, Labours And Materials For Painting, Numbering And Year For Construction Of T / Well And Taking Of Colour Photograph With Two Or Three Nearest Persons Including Platform, Drain, Soak Pit And Also Longitude & Latitude, Details Of T / W Such As Total Depth, Casing Depth, Static Water Level, Drawdown, Discharge, Strata Chart, Beneficiary Population Etc In Separate Sheet / Format All Complete As Per Direction Of E / I. , Cost Of Materials , Cost Of Standard I.S.I. Mark Deep Well Hand Pump For India Mark-Ii, I.S.I. 15500 ( Part 2 ) / 2004 With Latest Revision Including 12Mm X 3 Meter Long 8 No. Connecting Rods Made Of Bright Bar Electro-Galvanized Fitted With Coupler & Normal Stand Assembly Recommended For Use With Cylinder Assembly Suitable For Bore Wellcasing Pipe. , Cost Of 32 Mm Dia Gi Pipe ( Medium ) 3 Mtrs Long Screwed At Both Ends With Seamless Socket As Per Is:1239 ( Part 1990 ) . , Cost Of 125 Mm Dia Blue Upvc Casing Pipe As Per I.S.12818 / 2016 Cml No.- 5543459 , Rcc Foundation For Steel Structurestaging& Solar Panel , Earth Work In Excavation In Foundation Trenches In Ordinary Soil And Disposal Of Excavated Earth As Obtained To A Distance Up To 50.0M , Including All Lifts, Levelling , Ramming The Foundation Trenches, Removing Roots Of Trees, Shrubs All Complete As Per Approved Design , Building Specification And Direction Of E / I ( Vide Classification Of Soil Item -B ) , Providing Coarse Clean Sand In Filling In Foundation Trenches Or In Plinth Including Ramming And Watering In Layers Not Exceeding 150Mm Thick With All Leads And Lifts Including Cost Of All Materials , Labour , Royalty And Taxes All Complete As Per Building Specification And Direction Of E / I , Providing Designation 75 A One Brick Flat Soling Joints Filled With Local Sand Including Cost Of Watering Taxes Royalty All Complete As Per Building Specification And Direction Of E / I , Providing Nominal Mix Pcc Of ( 1:4:8 ) In Foundationwith Approved Quality Of Stone Chips 20Mm To 6Mm Size Graded And Clean Coarse Sand Of F.M.2.5To 3 Including Screening Shuttering Mixing Cement Concrete In Mixer And Placing In Position Vibrating Striking Curing And Royalty All Complete As Per Building Specification And Direction Of E / I , Providing Rcc M-20 In Nominal Mix Of ( 1:1.5:3 ) In Columnswith Approved Quality Of Stone Chips 20Mm To 6Mm Size Graded And Clean Coarse Sand Of F.M.2.5To 3 Including Screening Shuttering Mixing Cement Concrete In Mixer And Placing In Position Vibrating Striking Curing And Royalty All Complete As Per Building Specification And Direction Of E / I. , ( A ) Foundation For Steel Structure Staging , Footing And Vertical Pedestal Raft , Column , Tie Beam , ( B ) Foundation For Solar Panel , Footing , Vertical Pedestal , Providing For Steel Reinforcement As Per Approved Design And Drawing Excluding Carriage Of T.S. Bar To Work Site Cutting, Bending With Annealed Wire With Cost Of Wire, Removal Of Rust Placing The Rods In Position All Complete As Per Building Specification And Direction Of E / I. , ( A ) Foundation For Steel Structure Staging , Carriage Of Materials From Different Sources Or Departmental Stores To Work Site Including Loading, Transporting, Unloading And Stacking The Materials At Work Site Etc. All Complete Job. As Per Direction Of E / I. , Cement Lead 20 Km ( Avg. ) , Sand Lead 20 Km ( Avg. ) , Stone Chips Lead 20 Km ( Avg. ) , Steel Reinforcement Lead 20 Km ( Avg. ) , Bricks Lead 20 Km ( Avg. ) , Galvanized Tubular Steel Structure Staging Forhdpe Water Storage Tank& Solar Panel , Providing Structural Steel Galvanisedsqure Pipe Section Work In Trusses, Other Similar Trussed Purlins And Members With All Bracing , Gusset Plates Etc As Per Detailed Design And Drawing Or As Directed By Engineer- In-Charge , Including Cutting Fabricating , Hoisting , Erecting And Fixing In Position , Making Riveted / Bolted / Welded Connections And One Coat Of Anticorrosive Paint And Over It Two Coat Of All Oil Painting & For Structure ( Plus ) Providing And Applying Materials &Labour For Hot Dip Galvanizing Of Above Structure Including Transportation For Galvanizing Minimum Thickness 80Microns ( Net Wt. Of Components To Be Galv ) Preferably Tata Structural Section Etc Complete. , Hardware ( L.S. ) , Information Board For Iec , Installation Of 5000 Liters Capacity Water Storage Tank , Providing And Fixing Hdpe Container Syntex Or Alike One Piecemolded Water Tank Made Out Of Low Density Polythyler Andbuilt Corrugation Including Of Delivery Up To Destination Hoisting And Fixing Of Accessories Such As Inlet, Outlet Overflow Of All Tanks Capacity 5000.00 Litres Capacity Water Storage Tank , Transportation Charge , Lifting Of 5000 Litrs Capacity Tank Up To 4.00M Height With Lifting Tools With Rope And Labour , Making Hole In Tank , Making Long Screw In G.I. Pipe Including Supplying And Fitting Jam Nuts And Extra Socket Etc. , Rising And Distribution Network With House Connection Up To 20 Nos. Including Platform & Stand Post , Earth Work In Excavation In Foundation Trenches In Hard Soil ( Vide Classification Soil Item B ) And Disposal Of Excavated Earth As Obtained To A Distance Up To 50 Mtr. Including All Lifts, Leveling, Ramming The Foundation Trenches, Removing Roots Of Trees, Shrubs All Complete As Per Approved Design, Specification And Direction Of E / I. , Dismantling Plain Cement Concrete Work Including Stacking Serviceable Materials In Countable Stacks Within 15 M Lead And Disposal Of Unserviceable Materials With All Leads All Complete , Providing Pccm-200 With Nominal Mix Of ( 1:1.5:3 ) With Approved Quality Of Stone Chips 20 Mm To 6 Mm Size Graded And Clean Coarse Sand Of Fm 2.5 To 3.0 Including Screening, Shuttering, Mixing Cement Concrete In Mixer And Placing In Position, Vibrating, Sticking, Curing , Taxes And Royalty All Complete As Per Specification And Direction Of E / I. For Construction Of Road Cutting Portion , Rising Main , Manufacture, Supply And Delivery Offollowing Nominal Dia Upvc Column Pipes Including Pvc Socket ( Coupler ) , , 65Mm Dia -Density Of Pipe 1.38 To 1.43 Gm Per Cm3 Od:74.5 To 75.2Mm Wall Thickness End:9Mm To 10.7Mm, Barrel 9Mm To 10.7 Mm, Length: 3Mtrs.Rising Main , 50 Mm Dia -Density Of Pipe 1.38 To 1.43 Gm Per Cm3 Od:87.5 To 88.2Mm Wall Thickness End:9 .8 Mm To 11.9Mm, Barrel 7.3Mm To 9 Mm, Length: 3Mtrs. Delivery Pipe , Distribution , Providing And Supplying High Density Polyethylene Pipe ( Hdpe Pipe ) Of 20 Mm To 225 Mm Od And Pressure 6.0 Kg / Cm2 And 10 Kg / Cm2 Suitable For Water Supply Which Is Available In All Standard Conforming To Isi -- 4984 / 14151 / 12786 / 13488, Iso 4427 , Din-8074Materials Rates Are Ex-Factory Excluding Transportation, Taxes And Duties. , 63 Mm Hdpe Pipe , 50 Mm Hdpe Pipe , 32 Mm Hdpe Pipe , 20 Mm Hdpe Pipe , Providing And Fixing Gun Metal Gate Valvewith C I Wheel Of Approved Quality ( Screwed End ) . , 65Mm Dia , 50Mm Dia , Providing And Supplying High Density Polyethylene ( Hdpe ) Fittings Of 20 Mm To 225 Mm Od And Pressure 6.0 Kg / Cm2 And 10 Kg / Cm2 Suitable For Water Supply Which Is Available In All Standard Conforming To Isi -- 4984 / 14151 / 12786 / 13488, Iso 4427 , Din-8074Materials Rates Are Ex-Factory Excluding Transportation, Taxes And Duties. , Lowering, Laying And Jointing H. D. P. E. / M. D.P. E. Pipes In Proper Position Including All Specials By Compression Fitting / Electro Fusion And Butt Fusion Jointing Procedure As Per Relevant Is Code Complete With All Materials For Jointing Procedure Like Electro Fusion Machine, Electric Heater / Butt Fusion Welding Machine With Hydraulic Jack, Top Loading Clamp Etc. And All Labours As Directed By Engineer In Charge As Per Is-7634 Part Ii. , For Rising , 65 Mm Hdpe Pipe , 50 Mm Hdpe Pipe , Distribution , 65 Mm Hdpe Pipe , 50 Mm Hdpe Pipe , 32 Mm Hdpe Pipe , 20 Mm Hdpe Pipe , Providing 15 Mm Dia. G.I. Pipe Tata Or Equivalent Make As Per Is 1239 ( Part 1 / 2004 ) Isi Mark / Medium Quality In Stand Post. , Supplying All Materials , Labour And Tools For Fixing 15 Mm Dia G.I. Pipes With Red Lead And Yarn Of Following Nominal Bore With Screwed And Socketed Joints On Wall, Ceiling And Floor Including Supplying And Fitting Of Wall Hooks Or Pipe Clamps, Wooden Plugs, Cutting Pipes To Size And Threading Ends If Required Etc. All Complete As Per Specification And Direction Of Engineer-In-Charge. , Supplying And Fixing G.I. Fittings Of Approved Make All Complete As Per Specification And Direction Of E / I. , Elbow 15 Mm Dia. , Reducer Socket 20X15 Mm Dia. , Nipple 15 Mm Dia. , Plain Socket 15 Mm Dia. , Supplying And Fixing G.M. Ferrule Of Approved Make In Existing C.I. / D.I. Main Including Drilling And Taping C.I. / D.I. Main All Complete As Per Specification And Direction Of E / I. 3 Mm, 6 Mm 10 Mm Dm Ferrule Weight Not Less Than 425 Gram. , Providing And Fixing Gun Metal Full Way Valve Of Approved Quality, All Complete, As Per Specification And Direction Of E / I. , 65 Mm Dia Full Way Valve , 50 Mm Dia And Weight Not Less Than 1.5 Kg. , Providing And Fixing Of Male Ended C.I.Body Brass Spindle Valve And Seat Bib Cock Of Approved Quality With Extra Socketall Complete As Per Specification And Direction Of E / I. , 15 Dia And Weight Not Less Than 400 Gm , Constructing Masonry Chamber 30X30x50 Cm Inside, In Brick Work In Cement Mortar 1:4 ( 1 Cement :4 Coarse Sand ) For Stop Cock, With C. I. Surface Box 100X100 X75 Mm ( Inside ) With Hinged Cover Fixed In Cement Concrete Slab 1:2:4 Mix ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size ) , I / C Necessary Excavation, Foundation Concrete 1:5:10 ( 1 Cement : 5 Fine Sand : 10 Graded Stone Aggregate 40Mm Nominal Size ) And Inside Plastering With Cement Mortar 1:3 ( 1 Cement : 3 Coarse Sand ) 12Mm Thick, Finished With A Floating Coat Of Neat Cement Complete As Per Standard Design.With Common Burnt Clay F.P.S. ( Non Modular ) Bricks Of Class Designation 7.5. Full Way Valve Chamber , Supplying Materials , Labours And Equipments For Construction Of 0.90M X 0.90 M Size P.C.C. ( 1:2:4 ) Rectangular Platform With Stand Post In House Including 12 Mm Thick Cement Plaster In C.M. ( 1:4 ) With Neat Cement Punning Over Exposed Surfaceall Complete Job, As Per Approved Design, Specification And Direction Of E / I. , Providing Brick Masonry Chamber Ofinner Size 600 X 600 X 450 Mm Deep For Bore Well Protection Having 125 Mm Thick Wall And 75 Mm R.C.C Cover Including Cement Plaster Of Exposed Surface, Etc All Complete Job , Earth Work In Back Filling The Trenches After Laying Different Types And Size Of Pipes With Earth Removed During Excavation Within Initial Lead And Lift As Per Specification And Direction Of Engineer-In-Charge. , Providing Fitting & Fixing 32 Mm To 50 Mm Service Hdpe Saddleall Complete Job, As Per Approved Design, Specification And Direction Of E / I. , Solar Photovoltaic ( Spv ) Solar Submersible D.C. Water Motor Pump , Designing, Supplying, Installation, Testing & Commissioning With All Tools & Parts Of Following Solar Photovoltaic ( Spv ) Solar Submersible D.C. Water Motor Pump Suitable For Minimum 125Mm X 115Mm Bore Well As Per Mnre Guideline With Following Specifications & Accessories. , Spv Arrays Contains Specified No Of Same Capacity Type & Specification Modules Connected To Series Or Parallel To Obtained The Required Voltage & Current The Power Output Of Individual Pvmodules Should Be Minimum 200 Watt Peak. , I ) The Spv Modules Should Be As Per Iec-61215 And Iec 61730 Part 1.0 ) , Ii ) All External Parts Of Motor Pump Used In Submersible Pump Which Are In Contact Of Water Is Stainless Steel Grade 303 Or Higher As Required. , Iii ) The Pv Modules Shouldbe Mounted On Metallic Structure Of Adequate Strength And Appropriate Design Which Can Withstand Load Of Modules & High Wind Pressure Up To 200Km / H. , Iv ) The Module Mounting Structure Should Be Hot Dip Galvanized According To Is 4759. , V ) To Enhance The Performance Of Spv Water Pumping System & Arrangement For Seasonal Tilt Angle Adjustment Should Be Provided , Vi ) Necessary Arrangement Should Be Provided In Controller Automatic Start-Run-Stop Through Out The Day With Water Level Detection System. ( As Per Mnre Specification ) , Vii ) Necessary Protection Such As Lightening Arrestor Etc. Should Be Provided To Protect The Controller & Spv , Viii ) The Suction / Delivery Pipe Shall Be Upvc / H.D.P.E. Pipes Of Appropriate Size 60M Or More As Required Minimum Pressure Rating Of 8Kg / Sq Cm- Pe 100 Grade For Pump Up To 3Hp & 10 Kg / Sq Cm- Pe 100 Grade For 5 Hp. , Ix ) All Cable Used Shall Be As Per Is 694. Suitable Size Of Cable Shall Be Used In Sufficient Length For Inter Connection Between The Spv Array To Spv Controller And Spv Controller To Solar Power Pump. Provision Of Cable Shall Be As Per Is 14536. , X ) The Motor Pump Set Should Have A 5 Years Warranty. , Xi ) Control Panel Suitable For Motor Pump With Arrangement Of Dry Run & Over Flow Protection Sensor, Float Switch & Rain Prevention Box. ( As Per Mnre Specification ) , Xii ) The Spv Controller Must Have Ip-65 Protection Or Must Be Housed In Cabinet Having At Least Ip-65 Protection. , Xiii ) The System Should Be As Per Mnre Guide Line & Eco-Friendly With Suitable Arrangement To Operate New Pump Manually. , Xiv ) With Third Party Inspection Before Dispatch. , Xv ) Provision For Web Basedremote Monitoring Of The Pumps To Be Installed Must Be Made Through The Inbuilt Controllers . It Should Be Possible To Ascertain The Daily Water Output, The Power Generated By Pv Array , The Up And Downtime Of The Pump During The Year, Number Of Days The Pump Was Unused Or Under Breakdown Repairs. , The Following Details Should Be Marked Indelibly On The Motor Pump Set , A ) Name Of The Manufacturer Or Distinctive Logo. , B ) Model Number. , C ) Serial Number. , Solar Submersible Motor Pump ( Spv Dc Type ) , I ) 1 Hp ( Dc Pump ) With 900 Wp Minimum Watt P.V. Panel As Mnre Pump Head Max Shut-Off Head Up To 120 Mtrs. For Higher Or Lower Head Or In Between Various Modules Output Could Be Decided On Prorates Basis. ( As Per Latest Guide Line Of Mnre ) , Carrying Out Recuperation / Yield Test For Ascertaining The Discharge Of Constructed Well / Excavated Profile As Directed By The Iec. The Testout By The Drawing Down Water From The Well / Profile Below Normal / Subsoil Water Level Up To Full Depth Rise Is Recorded The Normal Water Level / Subsoil Water Level In The Well / Profile As Well As Strainer / Level At Pump As Per Design Of W.S. Scheme Shall Be Recorded Prior To The Test Including Cost Of All Materials, Over Load , Labours Etc. Complete As Directed. , Supplying All Labours, Tools And Equipments For Dismantling Of Head & Water Tank Assembly And Taking Out 32 Mm Dia Old G.I. Pipe, Connecting Rod, Cylinder Assembly The Dismantled Components After Necessary Changing For Making The T / W In Good Condition With All Transportation Including Unused Taken Out Materials Back In Store All Complete Job As Per Direction Of E / I. ( As Per Model Estimate Of Solar Energy Based Mini Wss. Ts Done By Se, Ranchi Circle & Circle Gumla Dt. 21.05.2019 ) , Provision Of Solar Night Lamp. , Galvanised Chain-Line Mess Fencing Around Solar Panel Where Bore Well Is Away From Tower , Making 30 Cm ( 12 ) Dia Bore Up To 4M Below Ground With Hand Auger Of Approved Quality In Ordinary Soil ( Vide Classification Of Soil Item-A ) True To Plum And Without Eccentricity In Any Stage Of Operation And Disposal Of The Exacavated Earth Up To 50M Lead Including All Lifts All Complete As Per Approved Design And Direction Of E / I. , Providing Pcc M-150 In Nominal Mix Of ( 1:2:4 ) In Foundationwith Approved Quality Of Stone Chips 20Mm To 6Mm Size Graded And Clean Coarse Sand Of F.M.2.5 To 3 Including Screening Shuttering, Mixing Cement Concrete In Mixer And Placing In Position, Vibrating, Curing, Taxes And Royalty All Complete As Per Building Specification Direction Of E / I. , Labour Cost Of Fitting And Fixing Galvanised Chain-Link Mess Up Height Of 2 M Including Cost Of Staples ( But Excluding The Cost Of Cement Concete Angle Iron Posts, Its Cutting And Making Holes, Nuts And Bolts ) All Complete As Per Specification And Direction Of E / I. , Drilling 6Mm Dia Holes In M.S Angle Iron For Fixing Of Stables Etc. As Per Building Specification And Direction Of E / I. , Labour Cost Cutting Of M.S Angle Iron Posts To Required Length, One End Splitted As Fish Tailed In A Length Of 150Mm Complete As Per Building Sepcification And Direction Of E / I. , Supplying, Fitting And Fixing Straining Bolts With Nut Size 22Cm*10Mm Dia Tighten The Barbed Wire With Corner Post Complete As Per Building Specification And Direction Of E / I. , Supplying, Fitting And Fixing Galvanised Chain -Link Mess Having 3Mm Thick Wire Cell Type 40 X 40 Mm Fitted On M.S. Angle Frame With Two Diagonals Having 25X25x5mm Size Angle Including Cost Of Fabrication, Providing Necessary Bocking Arrangement With Haskal And Domny Duly Fixed In Angle Post, Applying A Priming Red Lead Paint Over Steel Work, Taxes Excluding The Cost Of Galvanised Chain-Link Mess All Complete. , Cost Of Galvanised Chain-Link Mess Having 3 Mm Thick Wire Cell Type 40X40 Mm Not Less Than 3.1 Kg / Sqm , Cost Of 50 X50 X6 Mm M.S Angle , Carriage Of Materials From Different Sources Or Departmental Stores To Work Site Including Loading, Transporting, Unloading And Stacking The Materials At Work Site Etc. All Complete Job. As Per Direction Of E / I. , Cement Lead 20 Km ( Avg. ) , Sand Lead 20 Km ( Avg. ) , Stone Chips Lead 20 Km ( Avg. ) , Steel Reinforcement Lead 20 Km ( Avg. ) , Annual Operation & Maintenance Cost Based On Existing D / T Well With Solarmotor Pump For 5 Years , O & M Cost For 1St Year ( Excluding Repair Charges ) , O & M Cost For 2Nd Year With Annual Repair Charges , O & M Cost For 3Rd Year , O & M Cost For 4Th Year , O & M Cost For 5Th Year , Provision Of One No Sim Card & Its Recharging Cost For Rmc , 12% Gst , Labour Cess
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
43.
Drinking Water Supply and Sanitation #8962403 Technical Bid
E Quotation For Procurement Of Rate Of Materials- M079-Polythene Water Storage Tank Of Isi Mark ( E.G Sintex / Sinter / Himgiri / Gangotietc ) With Cover And Locking System 2 M129hdpe Pipes 75Mm Dia 3 M130hdpe Pipes 90Mm Dia 4 M193gi Pipe 50 Mm Dia ( Tata Or Equivalent Make ) 5 M337jute 6 M922g.M. Ferrules 7 ( I ) 8 Mm Dia Wt. Not Less Than 400 Gms 8 ( Ii ) 10 Mm Dia Wt. Not Less Than 400 Gms 9 ( Iii ) 15 Mm Dia Wt. Not Less Than 400 Gms 10 ( Iv ) 20 Mm Dia Wt. Not Less Than 600 Gms 11 ( V ) 25 Mm Dia Wt. Not Less Than 900 Gms 12 M923stop Cocks 13 ( I ) 15 Mm Brass Stop Cock Wt. Not Less Than 300 Gms 14 ( Ii ) 20 Mm Brass Stop Cock Wt. Not Less Than 400 Gms 15 ( Iii ) 25 Mm Brass Stop Cock Wt. Not Less Than 575 Gms 16 ( Iv ) 32 Mm Brass Stop Cock Wt. Not Less Than 850 Gms 17 ( V ) 40 Mm Brass Stop Cock Wt. Not Less Than 1.15 Kg 18 ( Vi ) 50 Mm Brass Stop Cock Wt. Not Less Than 2.15 Kg 19 ( Vii ) 15 Mm Dia C.I. Body Brass Working Part Stop Cock. 20 ( Viii ) 20 Mm Dia C.I. Body Brass Working Part Stop Cock. 21 ( Ix ) 25 Mm Dia C.I. Body Brass Working Part Stop Cock. 22 M924g.M. Full Way Valve 23 ( I ) 15 Mm Dia Wt. Not Less Than 300 Gms Without Wheel 24 ( Ii ) 20 Mm Dia Wt. Not Less Than 400 Gms Without Wheel 25 ( Iii ) 25 Mm Dia Wt. Not Less Than 500 Gms Without Wheel 26 ( Iv ) 32 Mm Dia Wt. Not Less Than 700 Gms Without Wheel 27 ( V ) 40 Mm Dia Wt. Not Less Than 1.0 Kg Without Wheel 28 ( Vi ) 50 Mm Dia Wt. Not Less Than 1.4 Kg Without Wheel 29 ( Vii ) 65 Mm Dia Wt. Not Less Than 1.8 Kg Without Wheel 30 ( Viii ) 80 Mm Dia Wt. Not Less Than 2.5 Kg Without Wheel 31 M925g.M. Non Return Valve Vertical 32 ( I ) 15 Mm Dia Wt. Not Less Than 150 Gms 33 ( Ii ) 20 Mm Dia Wt. Not Less Than 250 Gms 34 ( Iii ) 25 Mm Dia Wt. Not Less Than 375 Gms 35 ( Iv ) 32 Mm Dia Wt. Not Less Than 600 Gms 36 ( V ) 40 Mm Dia Wt. Not Less Than 700 Gms 37 ( Vi ) 50 Mm Dia Wt. Not Less Than 1.0 Kg 38 ( Vii ) 65 Mm Dia Wt. Not Less Than 1.20 Kg 39 ( Viii ) 80 Mm Dia Wt. Not Less Than 1.50 Kg 40 ( Ix ) 100 Mm Dia Wt. Not Less Than 1.80 Kg 41 M926g.M. Non Return Valve Horizontal 42 ( I ) 15 Mm Dia Wt. Not Less Than 150 Gms 43 ( Ii ) 20 Mm Dia Wt. Not Less Than 250 Gms 44 ( Iii ) 25 Mm Dia Wt. Not Less Than 375 Gms 45 ( Iv ) 32 Mm Dia Wt. Not Less Than 600 Gms 46 ( V ) 40 Mm Dia Wt. Not Less Than 700 Gms 47 ( Vi ) 50 Mm Dia Wt. Not Less Than 1.0 Kg 48 ( Vii ) 65 Mm Dia Wt. Not Less Than 1.20 Kg 49 ( Viii ) 80 Mm Dia Wt. Not Less Than 1.50 Kg 50 ( Ix ) 100 Mm Dia Wt. Not Less Than 1.80 Kg 51 M927 Cocks 52 ( I ) 15 Mm Dia G.M. Bib Cock Wt. Not Less Than 300 Gms 53 ( Ii ) 15 Mm Dia Brass Bib Cock Wt. Not Less Than 400 Gms 54 ( Iii ) 15 Mm Dia C.I. Bib Cock Wt. Not Less Than 400 Gms 55 ( Iv ) 15 Mm Dia C.I. Body Brass Working Part Spray Painted Bib Cock Wt. Not Less Than 400 Gms 56 ( V ) 15 Mm Dia C.I. Brass Pillar Cock Cock Wt. Not Less Than 400 Gms 57 ( Vi ) 15 Mm C.I. Plug Cock Ordinary 58 ( Vii ) 15 Mm C.I. Push Cock Ordinary 59 M928chromium Plated Brass Fittings 60 ( I ) C.P. Shower Rose 100 Mm Dia 61 ( Ii ) C.P. Shower Rose 125 Mm Dia 62 ( Iii ) P.V.C. Shower Rose 150 Mm Dia 63 ( Iv ) P.V.C Shower Rose 125 Mm Dia 64 M929connection Pipe 65 ( I ) 15 Mm Dia X 30 Cm. Long Lead Connection Pipe With Brass Fittings. 66 ( Ii ) 15 Mm Dia X 45 Cm. Long Lead Connection Pipe With Brass Fittings. 67 ( Iii ) 15 Mm Dia X 30 Cm. Long Pvc Connection Pipe With Brass Fittings. 68 ( Iv ) 15 Mm Dia X 45 Cm. Long Pvc Connection Pipe Withbrass Fittings. 69 M930g.I. Fittings ( Conforming To I.S. - 1879 ) Isi Marked 70 [ A ] G.I. Bend 71 ( I ) 15 Mm 72 ( Ii ) 20 Mm 73 ( Iii ) 25 Mm 74 ( Iv ) 32 Mm 75 ( V ) 40 Mm 76 ( Vi ) 50 Mm 77 ( Vii ) 65 Mm 78 ( Viii ) 80 Mm 79 ( Ix ) 100 Mm 80 ( X ) 125 Mm 81 ( Xi ) 150 Mm 82 [ B ] Elbow Of The Following Sizes 83 ( I ) 15 Mm 84 ( Ii ) 20 Mm 85 ( Iii ) 25 Mm 86 ( Iv ) 32 Mm 87 ( V ) 40 Mm 88 ( Vi ) 50 Mm 89 ( Vii ) 65 Mm 90 ( Viii ) 80 Mm 91 ( Ix ) 100 Mm 92 ( X ) 125 Mm 93 ( Xi ) 150 Mm 94 [ C ] Tee Plain Of The Following Sizes 95 ( I ) 15 Mm 96 ( Ii ) 20 Mm 97 ( Iii ) 25 Mm 98 ( Iv ) 32 Mm 99 ( V ) 40 Mm 100 ( Vi ) 50 Mm 101 ( Vii ) 65 Mm 102 ( Viii ) 80 Mm 103 ( Ix ) 100 Mm 104 ( X ) 125 Mm 105 ( Xi ) 150 Mm 106 [ D ] Reducing Tee Plain Of The Following Sizes ( Taking Larger Dimension ) 107 ( I ) 20 Mm 108 ( Ii ) 25 Mm 109 ( Iii ) 32 Mm 110 ( Iv ) 40 Mm 111 ( V ) 50 Mm 112 ( Vi ) 65 Mm 113 ( Vii ) 80 Mm 114 ( Viii ) 100 Mm 115 ( Ix ) 125 Mm 116 ( X ) 150 Mm 117 [ E ] Socket Plain Of The Following Size ( Taking Larger Dimension ) 118 ( I ) 15 Mm 119 ( Ii ) 20 Mm 120 ( Iii ) 25 Mm 121 ( Iv ) 32 Mm 122 ( V ) 40 Mm 123 ( Vi ) 50 Mm 124 ( Vii ) 65 Mm 125 ( Viii ) 80 Mm 126 ( Ix ) 100 Mm 127 ( X ) 125 Mm 128 ( Xi ) 150 Mm 129 [ F ] Reducing Socket Plain Of The Following Sizes ( Taking Larger Dimension ) 130 ( I ) 20 Mm 131 ( Ii ) 25 Mm 132 ( Iii ) 32 Mm 133 ( Iv ) 40 Mm 134 ( V ) 50 Mm 135 ( Vi ) 65 Mm 136 ( Vii ) 80 Mm 137 ( Viii ) 100 Mm 138 ( Ix ) 125 Mm 139 ( X ) 150 Mm 140 [ G ] Union Socket Of The Following Sizes 141 ( I ) 15 Mm 142 ( Ii ) 20 Mm 143 ( Iii ) 25 Mm 144 ( Iv ) 32 Mm 145 ( V ) 40 Mm 146 ( Vi ) 50 Mm 147 ( Vii ) 65 Mm 148 ( Viii ) 80 Mm 149 ( Ix ) 100 Mm 150 ( X ) 125 Mm 151 ( Xi ) 150 Mm 152 [ H ] Plugs Of The Following Sizes 153 ( I ) 15 Mm 154 ( Ii ) 20 Mm 155 ( Iii ) 25 Mm 156 ( Iv ) 32 Mm 157 ( V ) 40 Mm 158 ( Vi ) 50 Mm 159 ( Vii ) 65 Mm 160 ( Viii ) 80 Mm 161 ( Ix ) 100 Mm 162 ( X ) 125 Mm 163 ( Xi ) 150 Mm 164 [ I ] Jam Nuts Of The Following Sizes 165 ( I ) 15 Mm 166 ( Ii ) 20 Mm 167 ( Iii ) 25 Mm 168 ( Iv ) 32 Mm 169 ( V ) 40 Mm 170 ( Vi ) 50 Mm 171 ( Vii ) 65 Mm 172 ( Viii ) 80 Mm 173 ( Ix ) 100 Mm 174 ( X ) 125 Mm 175 ( Xi ) 150 Mm 176 [ J ] G.I. Nipple Of The Following Sizes 177 ( I ) 15 Mm Dia X 100 Mm Long 178 ( Ii ) 20 Mm Dia X 100 Mm Long 179 ( Iii ) 25 Mm Dia X 100 Mm Long 180 ( Iv ) 32Mm Dia X 100 Mm Long 181 ( V ) 40 Mm Dia X 100 Mm Long 182 ( Vi ) 50 Mm Dia X 100 Mm Long 183 ( Vii ) 65 Mm Dia X 100 Mm Long 184 ( Viii ) 80 Mm Dia X 100 Mm Long 185 ( Ix ) 100 Mm Dia X 100 Mm Long 186 [ K ] G.I. Pipes Midium ( Tata Mark ) Or Equivalent As Per Is-1239 ( Part-01 ) / 2004 Isi Marked / Medium Quality 187 ( I ) 15 Mm Dia 188 ( Ii ) 20 Mm Dia 189 ( Iii ) 25 Mm Dia 190 ( Iv ) 32 Mm Dia 191 ( V ) 40 Mm Dia 192 ( Vii ) 65 Mm Dia 193 M931mirrors 194 ( A ) Mirror Of 6 Mm Thick Plain Glass 600 Mm X 450 Mm Beveled Edge Mirror Includingc.P. Brass Revolving Fittings 3 Mm Plywood Boardand C.P. Hinges Etc.To Fix The Mirror 195 ( B ) -Do- 450 Mm X 300 Mm -Do- 196 M932 ( A ) Glass Shelf 600 Mm X 125 Mm With C.P. Brass Rail 197 ( B ) -Do- 450 Mm X 125 Mm -Do- 198 M933 ( A ) C.P. Brass Towel Rail 20 Mm X 600 Mm With Bracket All Complete 199 ( B ) Anodized Aluminum 20 Mm X 600 Mm Towel Rail Complete With Brackets 200 M934c.P. Brass Soap Dish Medium Quality With Screw Andhinges Etc. 201 M935c.P. Liquid Soap Solution Holder 202 M936vitreous White Glazed Indian Water Closet Of Hindustan / Parry Ware / Cera / Naycer Or Anyotherequivalent Make 203 ( A ) 580 Mm Long 204 ( B ) 510 Mm Long 205 ( C ) 450 Mm Long 206 ( D ) 510 Mm Long White Glazed Fiber I.W.C 207 M937pair Of Vetreous White Glazed Foot Rest Of Hindustan / Parryware / Cera / Naycer Or Any Other Equivalent Make 208 M93815 Liters Capacity Pull And Let Go High Level C.I. Cistern Complete With Ball Cock And A Pair Of Bracket 209 M939 ( A ) 12.5 Liters Lowdown C.I. Cistern 210 ( B ) 10.0 Liters Capacity P.V.C. Low Design Cistern 211 M940 ( A ) White Glazed Vitreous E.W.C With P Trap Orany Other Equivalent Make 212 ( B ) E.W.C With S Trap 400 Mm High Of Hindustan / Parry Ware / Cera / Naycear Or Any Other Equivalent Make 213 ( C ) Black / White Plastic Seat For E.W.C -Do- As Above. 214 M941 ( A ) White Glazed Vitreous Earthen Were Urinal Flat Back Of Hindustan / Parryware / Cera / Naycer Or Any Other Equivalent Make 600 Mm X 350 Mm Size 215 ( B ) -Do- Squatting Small 450 Mm X 350 Mm 216 ( C ) -Do- Squatting Large 600 Mm X 350 Mm 217 ( D ) White Glazed Vitreous Earthen Ware Urinal Standing Corner Size 600 Mm X 350 Mm Hindustan / Parryware / Cera / Naycer Or Any Other Equivalent Make 218 ( E ) Partition Plate For Urinal 25 X 13 Size 219 ( F ) 5 Liters C.I. Automatic Cistern With All P.V.C Fittings 220 M942white Glazed Vitreous Wash Hand Basin 550 Mm X 400Mm Size Of Hindustan / Parryware / Cera / Naycer Or Any Otherequivalent Make 221 M943white Glazed Vitreous Earthen Ware Kitchensinks Of Hindustan / Parryware / Cera / Nayceror Any Other Equivalent Make 222 ( A ) Kitchen Sink 600 Mm X 450 Mm X 200 Mm ( 24 X 18 X 8 ) 223 ( B ) Kitchen Sink 600 Mm X 450 Mm X 250 Mm ( 24 X 18 X 10 ) 224 ( C ) Lab Sink 450 Mm X 300 Mm X 150 Mm ( 18 X 12 X 6 ) 225 ( D ) Lab Sink 300 Mm X 250 Mm X 150 Mm ( 12 X 10 X 6 ) 226 M944drain Board 227 ( A ) 600 Mm X 450 Mm ( 24 X 18 ) 228 ( B ) 525 Mm X 450 Mm ( 21 X 18 ) 229 M945h.C.I. Pipes 230 ( A ) 50 Mm Dia Single Socket 6-0 ( With Ear Weight 13 Kg ) 231 ( B ) 80 Mm Dia Single Socket 6-0 ( With Ear Weight 18 Kg ) 232 ( C ) 100 Mm Dia Single Socket 6-0 ( With Ear Weight 23 Kg ) 233 ( D ) 150 Mm Dia Single Socket 6-0 ( With Ear Weight 30 Kg ) 234 ( E ) 50 Mm Dia Double Socket 6-0 ( With Ear Weight 14 Kg ) 235 ( F ) 80 Mm Dia Double Socket 6-0 ( With Ear Weight 19 Kg ) 236 ( G ) 100 Mm Dia Double Socket 6-0 ( With Ear Weight 25 Kg ) 237 ( H ) 150 Mm Dia Double Socket 6-0 ( With Ear Weight 13 Kg ) 238 ( I ) 50 Mm Dia Single Socket 3-0 ( With Ear Weight 7.25 Kg ) 239 ( J ) 80 Mm Dia Single Socket 3-0 ( With Ear Weight 10.5 Kg ) 240 ( K ) 100 Mm Dia Single Socket 3-0 ( With Ear Weight 13.75 Kg ) 241 ( L ) 150 Mm Dia Single Socket 3-0 With Ear 242 ( M ) 50 Mm Dia Single Socket 2-0 ( With Ear Weight 5.35 Kg ) 243 ( N ) 80 Mm Dia Single Socket2-0 ( With Ear Weight 8.00 Kg ) 244 ( O ) 100 Mm Dia Single Socket 2-0 ( With Ear Weight 10.10 Kg ) 245 ( P ) 150 Mm Dia Single Socket 2-0 With Ear 246 ( Q ) 50 Mm Dia Single Socket 1-0 ( With Ear Weight 3.4 Kg ) 247 ( R ) 80 Mm Dia Single Socket 1-0 ( With Ear Weight 5.50 Kg ) 248 ( S ) 100 Mm Dia Single Socket 1-0 ( With Ear Weight 7.60 Kg ) 249 ( T ) 150 Mm Dia Single Socket 250 M946h.C.I. Fittings. 251 ( I ) Plain Bend Of Following Size 252 ( A ) 50 Mm Dia ( Weight Without Ear And Socket 2.75 Kg ) 253 ( B ) 80 Mm Dia ( Weight Without Ear And Socket 3.5 Kg ) 254 ( C ) 100 Mm Dia ( Weight Without Ear And Socket 4.5 Kg ) 255 ( D ) 150 Mm Dia ( Weight Without Ear And Socket 4.5 Kg ) 256 ( Ii ) Bend With Door With Following Size 257 ( A ) 50 Mm Dia ( Wight Without Ear And Socket 2.75 Kg ) 258 ( B ) 80 Mm Dia ( Wight Without Ear And Socket 4.00 Kg ) 259 ( C ) 100 Mm Dia -Do- 5.5 Kg 260 ( D ) 150 Mm Dia -Do- 261 ( Iii ) Single Junction With Door Of Followings Sizes. 262 ( A ) 50 Mm Dia ( Weight Without Ear And Socket 3.75 Kg ) 263 ( B ) 80 Mm Dia ( Weight Without Ear And Socket 6.50 Kg ) 264 ( C ) 100 Mm Dia -Do- 9.50 Kg 265 ( D ) 150 Mm Dia -Do- 266 ( Iv ) Double Junction With Door Of Following Sizes. 267 ( A ) 50 Mm Dia -Do- 4.5 Kg 268 ( B ) 80 Mm Dia -Do- 7.00 Kg 269 ( C ) 100 Mm Dia -Do- 13.00 Kg 270 ( D ) 150 Mm Dia -Do- 271 ( V ) Heel Rest Bend Of Following Sizes 272 ( A ) 50 Mm Dia 273 ( B ) 80 Mm Dia 274 ( C ) 100 Mm Dia 275 ( D ) 150 Mm Dia 276 ( Vi ) Cowel Of Following Sizes 277 ( A ) 50 Mm Dia ( Weight Without Ear And Socket 2.25 Kg ) 278 ( B ) 80 Mm Dia ( Weight Without Ear And Socket 3.25 Kg ) 279 ( C ) 100 Mm Dia ( Weight Without Ear And Socket 3.25 Kg ) 280 ( D ) 150 Mm Dia -Do- 281 ( Vii ) 100 Mm Dia P Trap ( Wt Without Ear And Socket ) 8.5 Kg 282 ( Viii ) 100 Mm Dia P Trap ( Wt Without Ear And Socket ) 8.8 Kg 283 ( Ix ) 100 Mm X 80 Mm Floor Trap ( Weight Without Ear And Socket ) 4.00 Kg 284 ( X ) Pass Over 50 Mm X 150 Mm For 50 Mm Projection 285 ( Xi ) -Do- 100 Mm X 150 Mm For 100 Mm Projection 286 ( Xii ) Inverted Junction Single 100 Mm X 50 ( Weight Without Ear And Socket ) 9.0 Kg 287 ( Xiii ) Inverted Junction Double 100 Mm X 50 Mm X 50 Mm ( Weight Without Ear And Socket ) 12.0 Kg 288 ( Xiv ) H.C.I. Offset 80 Mm Projection Of The Following Size 289 ( A ) 50 Mm Dia ( Weight Without Ear And Socket ) 2.75 Kg 290 ( B ) 80 Mm Dia -Do- 3.50 Kg 291 ( C ) 100 Mm Dia -Do- 5.00 Kg 292 ( D ) 150 Mm Dia -Do- 293 ( Xv ) H.C.I. Socket Of Following Sizes 294 ( A ) 50 Mm Dia ( Weight Without Ear ) 1.50 Kg 295 ( B ) 80 Mm Dia ( Weight Without Ear ) 3.00 Kg 296 ( C ) 100 Mm Dia ( Weight Without Ear ) 4.50 Kg 297 ( D ) 150 Mm Dia ( Weight Without Ear ) -Do- 298 M947c.I. Cover With Frame For Manhole And Inspection Chamber 299 ( A ) 600 Mm X 450 Mm Size ( Wt. 39 Kg ) 300 ( B ) 600 Mm X 450 Mm Size ( Wt. 25 Kg ) 301 ( C ) 500 Mm X 450 Mm Size ( Wt. 25 Kg ) 302 M948c.I. Bracket Pair For W.H.B 303 ( A ) 550 Mm X 400 Mm Size ( 22 X 16 ) 304 ( B ) -Do- For 12.5 Liter Cistern 305 ( C ) -Do- For 600 Mm X 450 Mm ( 24 X 18 ) Sink 306 ( D ) 40 Mm X 60 Mm Ms Plate Bracket For Sink As Above 307 M949 ( A ) 32 Mm ( 1 1 / 4 ) C.P. Brass Waste For W.H.B 308 ( B ) 40 Mm ( 1 1 / 2 ) C.P. Brass Waste For W.H.B For Sink 309 ( C ) 32 Mm ( 1 1 / 4 ) C.P. Waste Of White Metal 310 ( D ) 40 Mm ( 1 1 / 2 ) C.P. Waste Of White Metal 311 M950 ( A ) 32 Mm ( 1 1 / 4 ) P.V.C. Waste Pipe 750 Mm Long ( 26 Long ) Withbrass Union For W H B 312 ( B ) 40 Mm ( 1 1 / 2 ) P.V.C. Waste Pipe 750 Mm Long ( 26 Long ) With Brass Union For W H B 313 M95132 Mm ( 1 1 / 4 ) P.V.C. Telescopic Flush Pipe With Brass Union For High Level Cistern 314 M952rubber Inserttion 3 Mm ( 1 / 8 ) Thick 315 M953pig Lead 316 M954yarn 317 M955rubber Gasket For D.I Pipe Of Good Quality 318 ( A ) 80 Mm 319 ( B ) 100 Mm 320 ( C ) 125 Mm 321 ( D ) 150 Mm 322 ( E ) 200 Mm 323 ( F ) 250 Mm 324 ( G ) 300 Mm 325 ( H ) 350 Mm 326 ( I ) 400 Mm 327 ( J ) 450 Mm 328 ( K ) 500 Mm 329 ( L ) 600 Mm 330 ( M ) 700 Mm 331 ( N ) 750 Mm 332 ( O ) 800 Mm 333 ( P ) 900 Mm 334 ( Q ) 1000 Mm 335 ( R ) 1200 Mm 336 M956cotton Waste 337 M957asbestos Suta ( Gland Packing ) 338 M958solvent Cement 339 M959hydrocloric Acid ( Sepecific Gravity 1.20 ) 340 M960cp & Pvc Fitting 341 ( I ) 32 Mm Dia C.P. Waste 342 ( Ii ) 32 Mm Dia Pv C Waste Pipe 750 Mm Long With Coupling 343 ( Iii ) 40 Mm Dia C.P. Waste 344 ( Iv 40 Mm Dia Pvc Waste Pipe 750 Mm Long With Coupling 345 ( V 100 Mm Dia Steel Jali 346 ( Vi ) 15 Mm Dia C.P. Nipple With Coupling ( Short Pieces ) 347 ( Vii ) 50 Mm Dia Pvc Pipe With Coupling 348 M961special Type Of C.P. Bath Room Fittings For V.I.P.Buildings ( Jal, Jaquar, Marc Or Equivalent Mark ) 349 ( I ) Pillar Cock ( Isi ) 350 ( Ii ) Pillar Cock ( Long Neck ) 351 ( Iii ) Bib Cock ( Isi ) 352 ( Iv ) Bib Cock ( Long Thread ) 353 ( V ) Angular Stop Cock 354 ( Vi ) Angular Stop Cock ( Long Thread ) 355 ( Vii ) Concealed Stop Cock Reduce ( Isi ) 356 ( Viii ) Concealed Stop Cock Heavy-Duty Extra Adjustable Wall Flange 357 ( Ix ) Long Body Bib Cock 358 ( X ) Swan Neck Tap With Left Hand Operating Knob 359 ( Xi ) Central Hole Basin Mixer ( Best Quality ) 360 ( Xii ) Wall Mixer With Telephonic Shower Arrangement 361 ( Xiii ) Wall Mixer With Provision For Over Head Shower With Elbow Coupling And Well Flange 362 ( Xiv ) Wall Mixer 3 In 1 System With Provision For Over Head Shower With Elbow Coupling And Wall Flange 363 ( Xv ) Sink Mixer With Swinging Casted Spout 364 ( Xvi ) Sink Cock With Swinging Casted Spout 365 ( Xvii ) 4 - Way Diverter For Concealed Fittings 366 ( Xviii ) Pressure Adjustable Shower With Revolving Joint 367 ( Xix ) Telephone Shower With Flexible Pipe 368 ( Xx ) Flush Cock With Wall Flange ( 25 Mm ) 369 ( Xxi ) Towel Rail 24 370 ( Xxii ) Towel Ring 371 ( Xxiii ) Soap Dish 372 ( Xxiv ) Tumbler Holder 373 ( Xxv ) Toilet Paper Holder 374 ( Xxvi ) Glass Shelf 22 375 ( Xxvii ) Corner Glass Shelf With Bracket 376 ( Xxviii ) Flush Valve Complete With 32 Mm Size Controlcock & Flange 377 M962c.I Special & Pvc Pipes 378 1. C.I Double Shocketted Fittings Bend Such As Bend, Tee, Taper, 379 ( A ) 80-200 Mm 380 ( B ) 250-700 Mm 381 ( C ) 700-1000 Mm 382 2. C.I Double Flange Fittings Such As Tee, Taper, Tailpiece, Bend Etc 383 ( A ) 80-200 Mm 384 ( B ) 250-700 Mm 385 ( C ) 700-1000 Mm 386 Spare Parts Of Hand Pump 387 M963hexagonal Bolt M12x1.75X40mm Long Common To Marks Ii & Iii 388 M964hexagonal Nut M12x1.75Mm 389 M965washer M12 ( 2.5Mm Thick ) 390 M966high Tensile Bolt M10x1.5X40mm Long. 391 M967nyloc Nut M10x1.5Mm 392 M968handle Axle ( Stainless Steel ) 393 M969washer For Handle Axle ( 4Mm Thick ) 394 M970ball Bearing 6204 Z 395 M971spacer For Handle. 396 M972chain With Coupling. 397 M973hexagonal Bolt For Front Cover M12x1.75Mm Long. 398 M974nitrile Rubber Cup Washer For Mark – Ii & Iii 399 M975nitrile Sealing Ring Mark – Ii 400 M976nitrile Rubber Seating Big For Lower Valve Mark-Ii 401 M977nitrile Rubber Seating Small For Upper Valve Mark-Ii. 402 M978hexagonal Rod Coupling M12x1.75X50mm Long. 403 M979pump Head Assembly ( G.I. ) With Front Cover, Bolt & Third Plate. 404 M980front Cover ( G.I. ) 405 M981handle Assembly ( G.I. ) 406 M982 ( A ) Water Tank Assemblyfor Mark – Ii ( G.I. ) 407 ( B ) Water Tank Assembly For Mark – Iii ( Vlom-65 ) 408 M983stand Assembly ( G.I. ) Normal. 409 M984stand Assembly ( Telescopic ) ( G.I ) . 410 M985connecting Rod 3Mtr. Long With Coupling And Nut ( Electrogalvanized ) 411 M986a ) Cylinder Assembly Complete Set For Mark-Ii 412 B ) Cylinder Assembly Complete Set For Mark-Iii ( Vlom-65 ) 413 M987a ) Upper Valve Assembly Complete Set For India Mark-Ii 414 B ) Upper Valve Assembly Complete Set For India Mark-Iii ( Vlom-65 ) 415 M988a ) Lower Valve Assembly Complete Set For India Mark-Ii 416 B ) Lower Valve Assembly Complete Set For Im-Iii 417 M989reducer Cap For Cylinder Mark-Ii 418 M990a ) Plunger Rod ( S.S. ) For Mark – Ii 419 B ) Plunger Rod ( S.S. ) For Mark – Iii 420 M991upper Valve Guide ( G.M. ) . 421 M992rubber Seat Retainer For Mark-Ii 422 M993third Plate For Head Assembly ( Galanized ) 423 M994cylinder Body With Brass Liner For Im-Ii With Reducer Cap For Top And Bottom. 424 M995gun Metal Spacer. 425 M996check Valve Guide Mark-Ii 426 M997a ) Check Valve Seat For Mark – Ii 427 B ) Check Valve Seat For Mark – Iii 428 M998nitrile Rubber “O” Ring ( Vlom-65 ) 429 M999push Rod For Mark – Iii ( S.S ) . 430 M1000check Nut For Push Rod ( S.S. ) . 431 M1001nitrile Rubber Cup Washer For Vlom-50 432 M1002nitrile Rubber Sealing Ring For Mark – Iii Vlom-65 433 M1003nitrile Rubber Seating Big For Lower Valve Mk-Ii 434 M1004nitrile Rubber Seating Big For Lower Valve M-Iii Vlom-65 ) 435 M1005nitrile Rubber Bobbin Vlom-50 436 M1006nitrile Rubber “O” Ring Vlom-50 437 M1007nitrile Rubber Cone For Vlom-50 438 M1008nitrile Rubber Cone For Vlom-65 439 M1009nitrile Rubber Centralizer 150Mm For ( Vlom-65 ) . 440 M1010nitrile Rubber Centralizer 125Mm For ( Vlom-65 ) . 441 M1011nitrile Rubber Centralizer 150Mm For ( Vlom-50 ) . 442 M1012nitrile Rubber Centralizer 125Mm For Vlom-50 443 M1013nitrile Rubber Centralizer 100Mm For Vlom-50 444 M1014water Tank Assembly Mark – Iii Vlom-50 445 M1015cylinder Assembly Complete Set For Mark – Iii ( Vlom-50 ) 446 M1016upper Valve Assembly Complete Set For Im-Iii ( Vlom-50 ) 447 M1017lower Valve Assembly Complete Set For Im-Iii ( Vlom-50 ) 448 M1018a ) Upper Cap Cylinder Mark – Iii ( Vlom-65 ) 449 B ) Upper Cap Cylinder Mark – Iii ( Vlom-50 ) 450 M1019a ) Bottom Cap For Mark – Iii ( Vlom-50 ) 451 B ) Bottom Capfor Mark – Iii ( Vlom-65 ) 452 M1020follower For Im-Iii 453 M1021cage For Mark-Iii 454 M1022s.S. Hexagonal Bolt M-6X25mm Long. 455 M1023basic Rate Of Standard I.S.I. Mark Deep Well Hand Pump For India Mark-2, I.S.I. 15500 ( Part 2 ) / 2004 With Latest Revision Including 12Mm X 3Meter Long 8 No. Connecting Rods Made Of Bright Bar Electro-Galvanized Fitted With Coupler & Normal Stand Assembly Ecommended For Use With Cylinder Assembly Suitable For Bore Well Dia 100 To 125Mm Casing Pipe. 456 M1024basic Rate Of Upvc Pipe 125Mm Dia Conforming To I.S.I. Latest Revision Is 12818 / 2016 Cml No. 5543459 457 M1025basic Rate Of 32Mm G.I. Pipe In 3 Mtrs. Length ( Medium ) With Seamless Socket As Per Relevent B.I.S. Specificationis 1239 ( Part-I ) / 2004 458 M1026di Pipe : Providing And Supplying Isi Mark Centrifugally Cat ( Spun ) Ductile Iron Pipes Of 100 Mm And Above All Diameter For Water Works With Socket & Spigot Ends Confirming To Is 8329 / 2000 In The Standard Working Lengths Of 4.5, 5.5 & 6 M Suitable For Classification K-7 & K-9 Suitable For Push-On-Joint ( Rubber Gusket D Jointing ) With Cement Mortar Lining Inside The Pipes With Outside Zinc And Bittuminous Coating.Rates Are Ex Factoryexcluding Transpotion, Taxes & Duties, Contractor Profit & Overhead Charges Etc.Based On Wpi 100.3 Of May 2020 ( Including Cost Of One No. Gasket For Each Pipe ) 459 Note : ( I ) The Rates Are Exfactory But Exclusive Of Gst & C.P. Based On Wpi 100.3 Of May 2020. ( Ii ) Price Variation Of Di Pipe Will Be Calculated Based On Prevalling Wpi. 460 Size Class - K7 461 100 Mm Dia 462 150 Mm Dia 463 200 Mm Dia 464 250 Mm Dia 465 300 Mm Dia 466 350 Mm Dia 467 400 Mm Dia 468 450 Mm Dia 469 500 Mm Dia 470 600 Mm Dia 471 700 Mm Dia 472 750 Mm Dia 473 800 Mm Dia 474 900 Mm Dia 475 1000 Mm Dia 476 1100 Mm Dia 477 1200 Mm Dia 478 Size Class - K9 479 100 Mm Dia 480 150 Mm Dia 481 200 Mm Dia 482 250 Mm Dia 483 300 Mm Dia 484 350 Mm Dia 485 400 Mm Dia 486 450 Mm Dia 487 500 Mm Dia 488 600 Mm Dia 489 700 Mm Dia 490 750 Mm Dia 491 800 Mm Dia 492 900 Mm Dia 493 1000 Mm Dia 494 1100 Mm Dia 495 1200 Mm Dia 496 M1027providing And Supplying Of Isi Standarddi Specials & Fitting With Sealing Rubber Gasket Of Sbr, Complete With Cast Iron Follower Gland & Ms Nut Bolts Coated Or Otherwise Protected From Rusting And Suitable For Di Pipescomplete As Per Is-9523 Class K-12 ( Ex Factoryrates ) Inspection Charge Transportation , Cp Extra. 497 Socketed 498 100 -150 Mm Dia 499 200-300Mm Dia 500 350-450Mm Dia 501 500-600Mm Dia 502 700 Mm Dia 503 800 Mm Dia 504 900 Mm Dia 505 1000 Mm Dia 506 1100 Mm Dia 507 1200 Mm Dia 508 Flanged 509 100 -150 Mm Dia 510 200-300 Mm Dia 511 350-450Mm Dia 512 500-600Mm Dia 513 700 Mm Dia 514 800 Mm Dia 515 900 Mm Dia 516 1000 Mm Dia 517 1100 Mm Dia 518 1200 Mm Dia 519 M1028providing And Supplying In Standard Lengths High Density Polyethylene Pipe ( Hdpe Pipe ) Confirming To Is 4984-4984 / 14151 / 12786 / 13488 ( Latest Revision With Necessary Jointing Materials Like Mechanical Connector I.E. Thread / Insert Joint / Quick Release Coupler Joint / Compression Fitting Joint Or Flanged Joints Excluding Coupler / Specials And Taxes ) . 520 Hdpe Pipe Of Materials Grade Pe80-Pn06 ( Dia In Mm ) 521 25 Mm Dia 522 32 Mm Dia 523 40 Mm Dia 524 50 Mm Dia 525 63 Mm Dia 526 75 Mm Dia 527 90 Mm Dia 528 110 Mm Dia 529 125 Mm Dia 530 140 Mm Dia 531 160 Mm Dia 532 180 Mm Dia 533 200 Mm Dia 534 225 Mm Dia 535 250 Mm Dia 536 280 Mm Dia 537 315 Mm Dia 538 355 Mm Dia 539 400 Mm Dia 540 450 Mm Dia 541 500 Mm Dia 542 Hdpe Pipe Of Materials Grade Pe80-Pn10 ( Dia In Mm ) 543 25 Mm Dia 544 32 Mm Dia 545 40 Mm Dia 546 50 Mm Dia 547 63 Mm Dia 548 75 Mm Dia 549 90 Mm Dia 550 110 Mm Dia 551 125 Mm Dia 552 140 Mm Dia 553 160 Mm Dia 554 180 Mm Dia 555 200 Mm Dia 556 225 Mm Dia 557 250 Mm Dia 558 280 Mm Dia 559 315 Mm Dia 560 355 Mm Dia 561 400 Mm Dia 562 450 Mm Dia 563 500 Mm Dia 564 M1029providing And Supplying In Standard Lengths High Density Polyethylene Pipe ( Hdpe Pipe ) 25Mm To 500Mm Dia Confirming To Is 4984-4984 / 14151 / 12786 / 13488 ( Latest Revision With Necessary Jointing Materials Like Mechanical Connector I.E. Thread / Insert Joint / Quick Release Coupler Joint / Compression Fitting Joint Or Flanged Joints Excluding Coupler / Specials And Taxes. 565 Hdpe Pipe Of Materials Grade Pe100-Pn06 ( Dia In Mm ) 566 25 Mm Dia 567 32 Mm Dia 568 40 Mm Dia 569 50 Mm Dia 570 63 Mm Dia 571 75 Mm Dia 572 90 Mm Dia 573 110 Mm Dia 574 125 Mm Dia 575 140 Mm Dia 576 160 Mm Dia 577 180 Mm Dia 578 200 Mm Dia 579 225 Mm Dia 580 250 Mm Dia 581 280 Mm Dia 582 315 Mm Dia 583 355 Mm Dia 584 400 Mm Dia 585 450 Mm Dia 586 500 Mm Dia 587 Hdpe Pipe Of Materials Grade Pe100-Pn10 ( Dia In Mm ) 588 25 Mm Dia 589 32 Mm Dia 590 40 Mm Dia 591 50 Mm Dia 592 63 Mm Dia 593 75 Mm Dia 594 90 Mm Dia 595 110 Mm Dia 596 125 Mm Dia 597 140 Mm Dia 598 160 Mm Dia 599 180 Mm Dia 600 200 Mm Dia 601 225 Mm Dia 602 250 Mm Dia 603 280 Mm Dia 604 315 Mm Dia 605 355 Mm Dia 606 400 Mm Dia 607 450 Mm Dia 608 500 Mm Dia 609 M1034gpt / Hygpt :Drilling By Rotary Drill Machine Of Size 300Mm & 400Mm Dia With T.C. Drill Bit For Tubewells In All Kinds Of Soil Including Moorum, Hard Soil, Soil Mixed With Pebbles, Shingles, Compacted Soil, Clay, Soft And Decomposed Rock Etc, Up To 60 Meters Depth Including Reaming To Facilitate Smooth Lowering Of Casing Pipe Etc. As Per Specification And Direction Of E / I ( Basic Rates ) 610 300 Mm Dia For Gpt 611 400 Mm Dia For Hygpt 612 M1035hydt : Cost Of Drilling 200 Mm X 165 Mm X 125 Meter Deep Bore Well In All Kinds Of Soil And Rock In Rural Area For Installation Of Pump Set With Hydraulic Dth Rig Machine, All Complete Including Supplying All Materials, Tools, Drilling Rig, Air Compressor And Equipments, As Well As Fuel, Lubricants And Cost Of Transportation Of Rig Machine And Other Vehicles Up To The Site ( Basic Rates ) 613 From 0-50 Meter 614 From 51-125 Meter 615 M1036ms Pipe 616 Supplying All Tools, Tackles & Lowering Of 200 Mm Dia Ms Erw Casing Pipe Of 6Mm Wall Thickness Including Welding Charges, Cost Of Pipe Etc . All Complete Job ( Basic Rates ) 617 Supplying All Materia;Ls, Labours, Tools & Equipments For Fitting & Fixing 200Mm Dia Ms Cap Over Casing Pipe Complete Job ( Basic Rates ) 618 M1037dt :Basic Rates For 125 / 115 Mm Dia Drilled Tube-Well For Drilling In All Kinds Of Soil And Rock For Installation Of Hand Pump With Dth Rig Machine All Complete Including Supplying All Materials, Labours, Tools, Drilling, Rigs, Air Compressor And Equipments As Well As Fuel Lubricant, For Making 125 / 115 Mm Dia Boring Etc. And Cost Of Transporting Rig Machine And Other Vehicle Up To Site Of Work As Per Specification And Dirrection Of Engineer Incharge ( Basic Rates ) 619 Drillig Upto 30 Mtr Depth Below G. L. In Rural Area 620 Drilling Beyond 31 Mtr Upto 60 Mtr Below G. L. In Rural Area 621 M1038trenchless 622 Installation Of Product Pipe By Manual Pipe Jacking Method Including Making Of Entry And Exit Pits All Related Civil Works Like Excavation , Shoring / Strutting Etc Manual Shielded Excation , Lowering Of Pipe Segments In The Jacking Pit Laying And Jointing Of Product Pipeline Through Jacking Process From The Jacking Pit And Restoration Of Site After Project Completion As Per The Instruction Of The Engineering -In - Charge All Complete Exept The Cost Of The Pipe Average Cover Of 1.5 Depth Below Gi ( Upto 100 Meter Installation Length ) 623 From 900 Mm To 1000 Mm Dia 624 In Soft Soil 625 In Hard Soil 626 In Sandy Soil 627 In Stone Soil 628 From 1000 Mm To 1200 Mm Dia 629 In Soft Soil 630 In Hard Soil 631 In Sandy Soil 632 In Stone Soil 633 Above 1200 Mm To 1500 Mm Dia 634 In Soft Soil 635 In Hard Soil 636 In Sandy Soil 637 In Stone Soil 638 Installation Of Product Pipe By Auger Boring Methodincluding Making Of Entry And Exit Pits All Related Civil Works Like Excavation , Shoring / Strutting Etc Shielded Excavation , Through Auger Boring Process Lowering Of Pipe Segments In The Jacking Pit Laying And Jointing Of Product Pipeline Through Jacking Process From The Jacking Pit And Restoration Of Site After Project Completion As Per The Instruction Of The Engineering -In - Charge All Complete Exept The Cost Of The Pipe Average Cover Of 1.5 Depth Below Gi ( Upto 100 Meter Installation Length ) 639 Upto 300 Mm Dia 640 In Soft Soil 641 In Hard Soil 642 In Sandy Soil 643 In Stone Soil 644 Above300 Mm To 450 Mm Dia 645 In Soft Soil 646 In Hard Soil 647 In Sandy Soil 648 In Stone Soil 649 Above 450 Mm To 600 Mm Dia 650 In Soft Soil 651 In Hard Soil 652 In Sandy Soil 653 In Stone Soil 654 Above 600 Mm To 900 Mm Dia 655 In Soft Soil 656 In Hard Soil 657 In Sandy Soil 658 In Stone Soil 659 Installation Of Product Pipe By Guided Auger Boring Methodincluding Making Of Entry And Exit Pits All Related Civil Works Like Excavation , Shoring / Strutting Etc Shielded Excavation , Through Auger Boring Process Lowering Of Pipe Segments In The Jacking Pit Laying And Jointing Of Product Pipeline Through Jacking Process From The Jacking Pit And Restoration Of Site After Project Completion As Per The Instruction Of The Engineering -In - Charge All Complete Exept The Cost Of The Pipe Average Cover Of 1.5 Depth Below Gi ( Upto 100 Meter Installation Length ) 660 Upto 300 Mm Dia 661 In Soft Soil 662 In Hard Soil 663 In Sandy Soil 664 In Stone Soil 665 Above300 Mm To 450 Mm Dia 666 In Soft Soil 667 In Hard Soil 668 In Sandy Soil 669 In Stone Soil 670 Above 450 Mm To 600 Mm Dia 671 In Soft Soil 672 In Hard Soil 673 In Sandy Soil 674 In Stone Soil 675 Above 600 Mm To 900 Mm Dia 676 In Soft Soil 677 In Hard Soil 678 In Sandy Soil 679 In Stone Soil 680 M1039providing And Supplying Isi Mark Ci / D / F Reflux Valves ( Non Return Valves ) Of Following Dia Inspection Charges Unloading From Railway Wagon , Loading Into Truck Transportation Upto Department Stores / Site Unloading Stacking Etc. Complete Reflux Valve As Per Is 5312 Part I ( 1984 ) 681 Without Byepass Arrangement - Pn-1 682 50 Mm 683 65 Mm 684 80 Mm 685 100 Mm 686 125 Mm 687 150 Mm 688 200 Mm 689 250 Mm 690 300 Mm 691 350 Mm 692 400 Mm 693 450 Mm 694 500 Mm 695 600 Mm 696 700 Mm 697 750 Mm 698 800 Mm 699 900 Mm 700 1000 Mm 701 1100 Mm 702 1200 Mm 703 With Byepass Arrangement - Pn-1 704 50 Mm 705 65 Mm 706 80 Mm 707 100 Mm 708 125 Mm 709 150 Mm 710 200 Mm 711 250 Mm 712 300 Mm 713 350 Mm 714 400 Mm 715 450 Mm 716 500 Mm 717 600 Mm 718 700 Mm 719 750 Mm 720 800 Mm 721 900 Mm 722 1000 Mm 723 1100 Mm 724 1200 Mm 725 Without Byepass Arrangement - Pn-1.6 726 50 Mm 727 65 Mm 728 80 Mm 729 100 Mm 730 125 Mm 731 150 Mm 732 200 Mm 733 250 Mm 734 300 Mm 735 350 Mm 736 400 Mm 737 450 Mm 738 500 Mm 739 600 Mm 740 With Byepass Arrangement - Pn-1.6 741 50 Mm 742 65 Mm 743 80 Mm 744 100 Mm 745 125 Mm 746 150 Mm 747 200 Mm 748 250 Mm 749 300 Mm 750 350 Mm 751 400 Mm 752 450 Mm 753 500 Mm 754 600 Mm 755 Providing Double Flange Sluice Valve ( Size 50 Mm To 1200 Mm ) Confirming For Is - 2906 / 14846 Including Worn Gear Arrangements As Per Test Pressure Stailess Steel Spindle , Caps Transportation Etc. All Complete . 756 With Byepass Arrangement - Pn-1 757 50 Mm 758 65 Mm 759 80 Mm 760 100 Mm 761 125 Mm 762 150 Mm 763 200 Mm 764 250 Mm 765 300 Mm 766 350 Mm 767 400 Mm 768 450 Mm 769 500 Mm 770 600 Mm 771 700Mm 772 750 Mm 773 800 Mm 774 900 Mm 775 1000 Mm 776 1100 Mm 777 1200Mm 778 Without Byepass Arrangement - Pn-1 779 50 Mm 780 65 Mm 781 80 Mm 782 100 Mm 783 125 Mm 784 150 Mm 785 200 Mm 786 250 Mm 787 300 Mm 788 350 Mm 789 400 Mm 790 450 Mm 791 500 Mm 792 600 Mm 793 700Mm 794 750 Mm 795 800 Mm 796 900 Mm 797 1000 Mm 798 1100 Mm 799 1200Mm 800 Providing Double Flange Sluice Valve Confirming For Is - 2906 / 14846 Including Worn Gearas Per Test Pressure Stailess Steel Spindle , Caps Transportation Etc. All Complete For Rateincluding All Taxes . . 801 Without Byepass Arrangement - Pn-1.6 802 50 Mm 803 65 Mm 804 80 Mm 805 100 Mm 806 125 Mm 807 150 Mm 808 200 Mm 809 250 Mm 810 300 Mm 811 350 Mm 812 400 Mm 813 450 Mm 814 500 Mm 815 600 Mm 816 700Mm 817 750 Mm 818 800 Mm 819 900 Mm 820 1000 Mm 821 1100 Mm 822 1200Mm 823 With Byepass Arrangement - Pn-1.6 824 50 Mm 825 65 Mm 826 80 Mm 827 100 Mm 828 125 Mm 829 150 Mm 830 200 Mm 831 250 Mm 832 300 Mm 833 350 Mm 834 400 Mm 835 450 Mm 836 500 Mm 837 600 Mm 838 M1040design And Supply Of V -Wire Screen Laterals Suitable For Infiltration Galleryas Per Site Condition And Detail Provided End Connection Suitable Flange Excluding Taxes And Transportation . 839 Dia - 06 Inch ( 150 Mm ) 840 Id - 153 Mm Od -167 Mm 841 Screen Thickness - 07 Mm 842 Slot - 1.00 Mm 843 Moc - Lowcarbon Galvenised Steel 844 Length - 5 Mtr. 845 Dia - 08 Inch ( 200 Mm ) 846 Id - 205 Mm Od -221Mm 847 Screen Thickness - 08 Mm 848 Slot - 1.00 Mm 849 Moc - Lowcarbon Galvenised Steel 850 Length - 5 Mtr. 851 Dia - 10 Inch ( 250 Mm ) 852 Id - 256 Mm Od -276Mm 853 Screen Thickness - 10 Mm 854 Slot - 1.00 Mm 855 Moc - Lowcarbon Galvenised Steel 856 Length - 5 Mtr. 857 Dia - 12 Inch ( 300 Mm ) 858 Id - 306 Mm Od -326 Mm 859 Screen Thickness - 10 Mm 860 Slot - 1.00 Mm 861 Moc - Lowcarbon Galvenised Steel 862 Length - 5 Mtr. 863 Dia - 14 Inch ( 350 Mm ) 864 Id - 338 Mm Od -363 Mm 865 Screen Thickness - 12.5 Mm 866 Slot - 1.00 Mm 867 Moc - Lowcarbon Galvenised Steel 868 Length - 5 Mtr. 869 M1041supplying All Materials, Labours, Equipments For Lowering 125Mm Dia Blue Upvc Casing Pipe As Casing For Protecting The Sides From Falling During The Process Of Drilling All Complete Including Carriage Of Materials To Work Site ( Basic Rate ) . 870 M1042supplying All Tools, Equipments And Labour And Doing Washing, Flushing And Development Of Drilled Tube Well To Give Clean And Clear Water All Complete As Per Dirction E / I ( Basic Rate ) . 871 M1043supplying Labour Cement And Calcium Chloride Or Bentonite Solution And Equipments For Grouting The Casing Pipe After Lowering In The Bore Including Carriage Of Materials To Work Site Etc. All Complete As Per Specification & Direction Of E / I ( Basic Rate ) . 872 M1044supplying Labour And Equipments Including 125Mm Dia G.I. Cap And Fitting And Fixing Over The Casing Pipe Of Tube Well Properly And Taking It Out As Per Direction E / I ( The Cap Will Be The Property Of Department ) ( Basic Rate ) . 873 M1045supplying All Materials, Labours, Equipments For Constructing P.C.C. ( 1:2:4 ) Circular Platform Around Drilled Tube Well Including 12Mm Thick Cement Plaster ( 1:4 ) With Neat Cement Punning Over Exposed Surface As Per Unicef Design, Etc. All Complete Including Carriage Of Materials ( Basic Rate ) . 874 M1046supplying All Materials, Labours And Equipments For Constructing P.C.C. ( 1:2:4 ) Drain As Per Unicef Design Etc. All Complete Including Carriage Of Materials ( Basic Rate ) . 875 M1047supplying Extra Deep Well Hand Pump Complete Sets With Cylinder Assembly & Connecting Rod ( 12 Pcs ) As Per Is : 15500 Part-2 / 2004 ( Basic Rate ) . 876 M1048supply Of 200Mm Dia X 3.00M Long Upvc Casing Pipe Conferming To Is : 12818: 2016 ( Cml No. 5543459 ) Latest Revision Including Carrigae ( Basic Rate ) . 877 M1049supply Of 200Mm Dia Ribbed Screen Pipe Conferming Tois : 12818: 2016 ( Cml No. 5543459 ) Latest Revision Including Carrigae ( Basic Rate ) . 878 M1050supply Of 125Mm Dia Ribbed Screen Pipe Conferming Tois : 12818: 2016 ( Cml No. 5543459 ) Latest Revision Including Carrigae ( Basic Rate ) . 879 M1051supplying All Tools, Equipments And Labour And Lowering 32 Mm Dia Medium Quality G.I. Pipe In Drilled Tube Well In 3 Mtrs. Length All Complete As Per Dirction E / I Including Carriage Of Materials ( Basic Rate ) . 880 M1052supplying All Tools, Labour For Fitting And Fixing Deep Well Cylinder With Necessary Connecting Rod Complete Job As Per Specification & Direction Of E / I Including Carriage Of Materials ( Basic Rate ) . 881 M1053supplying All Materials, Labours And Fixing India Mark Ii Hand Pump With All Accessories All Complete Job As Per Direction Of E / I Including Carriage Of Materials ( Basic Rate ) . 882 M1054design, Supply, Installation Testing & Commissioning Of Packaged Water Treatment Plants ( Unconventional Type ) Of Different Capacity With ( 20 Hours Operation ) Comprising Of Lamella Clarifier, Static Mixture Flocculation Tank ( Smet ) , Multi Grade Filter ( Mgf ) With Best Quality Filter Media, Lime / Coagulant / Polymer Dosing System Hypo Chloride Dosing System, Raw Water Feed Pump / Clear Water Transfer Pump ( Either Or ) , Sludge Transfer Cum Recirculation Pump, Filter Feed Pump & Back Wash Pump Including All Fitting Like Valve And Other Special Fittings And Electrical Power Supply To The Different Supplied Units With Mcb Panel Internal Electrification With Lighting Arrangement With Treatment Plant Site With Provision Of Chemical Storage And Water Testing Boratoryfacility Should Be From A Reputed Manufacturer / Authorized Distribution / Authorized Dealer Conforming To Relevant Is Codes And Certified By Iso-9001-2008 & 14001, It Also Include Cost Of Civil Foundation, Including Clarified Water Tank Internal Connecting Pipe Line From Raw Water Inlet To Cwr And Applying Internal Epoxy Paint On The Supply Equipment All The Prices Are Exclusive Of Gst, Allied Structure / Items Which Are Site Specific Such As External Electrification, Approach Road, Foot Bridge, Cofferdam, Compound Wall, Scada And Automation, Cwr Pumps Etc Are To Be Considered Extra. 883 0.2 Mld 884 0.3 Mld 885 0.4 Mld 886 0.5 Mld 887 0.6 Mld
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 8
44.
Public Administrative Department #8903582 Technical Bid
Installation Of Cc Tv Cameras At Identified Places In The Municipal Area Installation Of Cc Tv Cameras At Identified Places In The Municipal Area , Supply Installation Testing And Commissioningof 8Mp, 1 / 2.7 Cmos Image Sensor, Low Illuminance, High Image Definition , Outputs Max. 8Mp ( 3840 × 2160 ) @15 Fps, And Supports 2688×1520 ( 2688 × 1520 ) @25 / 30 Fps , H.265 Codec, High Compression Rate, Ultra-Low Bit Rate , Built-In Ir Led, Max Ir Distance: 60 M , Roi, Smart H.264+ / H.265+, Flexible Coding, Focal Length 2.7 Mm–13.5 Mm, Applicable To Various Bandwidth And Storage Environments , Rotation Mode, Wdr, 3D Nr, Hlc, Blc, Digital Watermarking, Applicable To Various Monitoring Scenes , Intelligent Detection: Intrusion, Tripwire , Abnormality Detection: Motion Detection, Video Tampering, No Sd Card, Sd Card Full, Sd Card Error, Network Disconnection, Ip Conflict, Illegal Ac- Cess, Local Alarm, Voltage Detection, Audio Abnormal , Alarm: 1 In, 1 Out; Audio: 1 In, 1 Out; Supports Max. 256 Gb Micro Sd Card , 12V Dc / Poe Power Supply , Ip67 Protection Product Should Ce, Fcc, Ul, Rohs, Bis Certified.Make:Cpplus / Sony / Bosch / Pelco , Sitc Of 4Mp 30X Wdr Ip Ir Ptz Dome Camera 1 / 3 4Mp Ps Cmos Image Sensor, Max. 25 / 30Fps@4M, 50 / 60Fps@1080P Resolution, Powerful 30X Optical And 16X Digital Zoom, .265 And H.264 Triple Stream Encoding, Wdr ( 120Db ) , Day / Night ( Icr ) , 2D / 3D-Dnr, Eis, Roi, Defog, Auto Iris, Auto Focus, Up To 300 Presets, 8 Tour, 5 Pattern, Auto Scan, Auto Pan, Max 400° / S Pan Speed, 360° Endless Pan Rotation, Built-In 2 / 1 Alarm In / Out, Ip66, Poe+ , Micro Sd Card, 100 Mtr. Ir Product Should Ce, Fcc, Ul, Rohs, Bis Certified.Including 64Gb Sd Card.Make:Cpplus / Sony / Bosch / Pelco , Supply Installation Testing And Commissioning Of 2 Megapixel Full Hd Anpr Camera, Adopt 1 / 1.9Inch Starlight Cmos Image Sensor, High Color Reducibility, High Sensitivity, Super Low-Light Effect.Adopt H.265 Standard Hd Video Format And 50 / 60Fps Hd Video Frame Rate, Embedded Integration Component Design, Built-In A Variety Of Algorithms, Such As Anpr, Traffic Data Collection And Analysis, Vehicle Type Classification, Traffic Incidents Detection, Vehicle Brand Detection And So On. Support Regional Cropping, Details Can Be Seen With Low Bandwidth. A Variety Of Signals, Data And Communication Interface Up To 80M Of Traffic Counting Range. Support 250 Vehicle Brand And 8 Vehicle Type Recognition. Support Non-Motor Vehicle Detection. Support Traffic Flow, Occupancy, Headway, Average Speed, Queue Length Statistics. The Accurate Of Vehicle Capture Over 95%, The License Plate Recognition Rate Is Over 90%, When The Speed Is Below 80Km / H.Make:Cpplus / Sony / Bosch / Pelco , Supply Installation, Testing And Commissioningof 32Channel Ip Camera Input, H.265 / H.264 / Mjpeg Dual Codec Decoding, Max 320 Mbps Incoming Bandwidth, Up To 8Ch@1080P ( [email protected][email protected] ) Realtime Live-View, Up To 12Mp Resolution Preview&Playback, 2Hdmi / 1 Vga Simultaneous Video Output, 8 / 16 Channel Synchronous Realtime Playback, Grid Interface, Support Multi-Brand Network Cameras: Dahua, Arecont Vision, Axis, Bosch, Brickcom, Canon, Cp Plus, Dynacolor, Honeywell, Panasonic, Pelco, Samsung, Sanyo, Sony, Videotec, Vivotek And Etc. , Onvif Version 2.4 Conformance, 3D Intelligent Positioning With Dahua Ptz Camera, Support 8 Sata Hdds Up To 64 Tb, 4 Usb ( 2 Usb3.0 ) , Product Should Ce, Fcc, Ul, Rohs, Bis Certified.Make:Cpplus / Sony / Bosch / Pelco , Supply Installation, Testing And Commissioningnetwork Control Keyboard 3 Dimension Joystick Control Of Ptz Functions, Preset Position, Auto Scan, Auto Pan, Auto Tour & Pattern Control, Supports Rs485, Rs422, Usb, Rs232 And Network, Auxiliary Functions, Network Video Server, On-Screen Menu & User Operation Procedure Tips:Make:Cpplus / Sony / Bosch / Pelco , Supply Installation And Testing Commissioning Of 55 Led Monitor, 17, 55 Diagonal 4K Led Display, 2 X Hdmi Port, 1 X Vga Port, 2 X Usb Port, Inbuilt Media Player-Should Be As Per Oem For Web Browser & File Sharing Compatibility Through Ip, External Control-Rs232c ( In / Out ) Thru Stereo Jack, Rj45, Contrast Ratio - 4000;1, Response Time- 8 Ms, Brightness 350 Cd / M2 20 Watt Built In Speaker, Viewing Angle 178° X 178°, Wall Mount For Display:, Movable Arm Wall Mount With 45° Left / Right Movement, External Media Player Compatible For Above If Required Safety & Emc Certifications.Make:Sony / Lg / , Supply Installation And Testing Commissioning Ofgigabit Layer 2 Poe Switch 8 Port 10 / 100 / 1000Mbps+2Sfpuplink Gigabit All 8 10 / 100 / 1000 Ports Support Ieee802.3Af / At Standards, 2 Gigabit Sfp Fiber Port For Sfp Module, Ai Extend: 1-8 Port Rate Down To 10Mbps, But The Transmission Distance Up To 250 Meters, Ai Vlan: Isolating Ports 1-8 From Each Other, Suppress Network Storms Effectively And, Ai Poe Detect Pd, Power Failure And Restart Dead Equipment Make:Dlink / Cisco / Hp / Cpplus , Supply Installation And Testing Commissioning Of24-Port Gigabit Eathernet Switch , Support Ieee802.3, Ieee802.3U, Ieee802.3Ab Ethernet Standard, Support Full / Half Duplex Mode, Support Ieee802.3X Standard Flow Control, Support Ieee 802.3X Full Duplex Flow Control And Back Pressure Half Duplex Flow Control, Support Ieee 802.1X Channel Control Protocol, Provides 24 Adaptive Rj45 Port, Supporting 10 / 100 / 1000Mbps Connection Rate, Provide Up To 48Gbps Bandwidth And Non-Blocking Line Speed Forward, Provide Led Indicators Realize Simple Work Statement Reminder And Trouble Clearing, Support Port Input / Output Bandwidth Control, Support Up To 4Kv Port Of Lightning Protection.Make:Dlink / Cisco / Hp / Cpplus , Supply , Installation, Testing And Commissioning Of Ip 55 Outdoor Pole Rack 9U X550mm Wx 500Mmd. C Onstruction Of Material- 1.2 / 1.5Mm Thick Crca Sheet Each Enclosure Includes: A Very Compact Design, Welded Structure With Front Accessible The Side Panels Are Integrated Type & Welded With Canopy & Bottom Cover Rigid Frame That Can Be Fixed To The Pole Front Door With Filter, Louver & Lock 90Cfm, 230V Ac Fan - 2 Nos, Front Door Self Adhesive Thermal Foam From Inside Door Hinges - 2 Nos Cable Glands At Bottom Side For Cable Entry 19 Angles 9U - 2 Nos For Equipment Mounting Gasket ( As Per Ip55 Standard ) Pole Mounting Brackets At Rear Side- 2 Nos Hood For Air Inlet At Front Side Powder Coated Surface 3 Socket Pdu 5 Amp - 1 No. Finish : Light Grey -Ral 7035-Powder Coated Make:Mb / Rittal / Dlink / Cpplus , Supply And Erection Of5 Meters Gi Octagonalpole For Fixing The Cameras Along With Foundation Structure Make:Polmax / Utkarsh / Bajaj , Supply , Installation And Testing Of Rack Mounted 12 Port Liu Loaded With Pigtail, Adaptor, Patch Cord Etc. Make:Dlink / Molex / Digilink / Amp , Supply , Installation, Testing And Commissioning Of Rack Mounted 19 24 Portcat 6 Utp, 1.5-1.6 Mm Crs Chasis , Powder Coated Modular Patch Panels With Collapsible Shutters On Jacks To Support Latest Amendments Of Tia / Eia Cat 6 Specifications Make:Dlink / Amp / Molex / Digilink , Supply , Drawing And Testing Of Cat 6 Cable , Made Ofcombination Of Pvc And Ldpe Jacket, Can Be Used For Outdoor Installation, 4Pair, 24 Awg Utp Cat 6 Cable As Per Latest Ammendments Of Tia / Eia 568 B.2-1 Specifications. Make:Cpplus / Molex / Dlink / Amp , Supply , Drawing And Testing Of Outdoor 6 Fibersinglemode [ 9 Micron ] Glass Fiber Optic Cable As Per Latest Ammendments Of Tia / Eia 568B.3 , Gr 409 Core / Ul Listed Nec 770 Standards Make:Aksh / Dlink / Molex / Cpplus , Supply , Installation And Testing Of Indoor 1 Pair Singlemode [ 9 Micron ] Glass Fiber Optic Patch Cords Of Three Mtr Length As Per Latest Ammendments Of Tia / Eia 568B.3 And Iec 794 Standard Specifications Including St Ii / Sc / Lc / Mt-Rj / Pc Connectors At Both Ends As Per Requirements.Make:Syrotech / Molex / Dcb / Dlink , Supply , Drawing And Testing Of 3Cx2.5 Sqmm Armored Power Cable Make:Finolex / Rr Kable / Havelles , Supply And Drawing Of 50Mm Diahdpe Pipe , Supply And Installation Of Surveillance Hdd 6Tb Make:Seagate / Wd / Tishiba , Supply Installation Testing And Commissioning Of 1000Va Ups It Should High Endmicro Controller Based, Wide Input Voltage Range, Short Circuit And Overloadprotection, Over Temperature Protection, Output Frequency Fixed At 50Hz Or Canbe Synchronized With Input Frequency, Static Bypass Enable Or Disable, Protectionfrom Dc Fan Failure, 14 Ah Battery Capacity, Power Backup 45Min. Make:Apc / Numeric / Emerson , Supply Installation And Testing Of Media Converter 10 / 100 / 1000Mbps Make:Dlink / Techroute / Syrotech , Construction Of Chamber For 100Mm Sluices Valve
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 3
45.
Defence #8762559 AOC
Tender For Maintenance And Repair To External Water Supply And External Electric Supply, External Street Lights And Connected Work At Ebs Babugarh Under Ge (North) Meerut Cantt.; 1 M&L for laying andtesting 20 mm bore GI tubing medium grade with all required fittings and fixtures laid in trenches, on the ground or on supports or fixed to walls incl taking up or down old unsv pipe making good of disturbed surfaces of roads, path ways etc. complete all as specified and directed. 2 All as per Srl item No 1 but 25mm bore complete all as specified and directed. 3 All as per Srl item No 1 but 40mm bore complete all as specified and directed. 4 All as per Srl item No 1but 50mm bore complete all as specified and directed. 5 M&L for laying andtesting 150 mm bore DI pipes with spigot and socket ends centrifugally cast class K7 in any length suitable for and including tyton joints laid in trenches including necessary cut to length to match the existing fitting / pipes incl taking up or down old unsv pipe making good of disturbed surfaces of roads, path ways etc. complete all as specified and directed. 6 All as per Srl item No. 6 but 100mm bore complete all as specified and directed. 7 All as per Srl item No. 6 but 80mm bore complete all as specified and directed. 8 M&L for taking up or down 80 to 150 mm bore Cast Iron water mains (including all fittings), with spigot and socket ends and lead joints cleaning the pipes free from sedimentation / scaling etc. and re-laying the same in trenches, on the ground or on supports or fixed to walls incl testing complete all as specified and directed. 9 Note for item No 1 to 9 :- Earth work shall be measured and paid separately. 10 Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for laying of Cable or Pipe, electric pole, stay assembly etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/ losse soil complete all as specified and as directed. 11 Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm. in soft/ losse soil complete all as specified and as directed. 12 Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting pointin soft/ losse soil complete all as specified and as directed. 13 M&L forhorizontal boring for road crossing for laying upto 200 mm bore water supply pipe lines across under roads, foot path etc. and making good disturbed areas as beforecomplete all as specified and directed. 14 M&L for lead joint and testing for 80 to 100 mm bore CI/DI pipe including spun yarn etc. for spigot & socket pipes and fittings complete all as specified and directed. 15 All as per Srlitem No. 14 but 150mm bore complete all as specified and directed. 16 M&L for CI or DI fittings for spigot and socket pipes such as bends (any type, radius and angle), tapers any type (straight, bend, increasing, decreasing or double socket etc), tee pieces, D clamps, angle branch, cross (all sockets or socket & spigot collars, caps and plugs for joining up to 200 mm bore CI pipe in repairs complete all as specified and directed. 17 S&F and testing, 80mm dia CI non rising type sluice valve both ends flanged with CI body, ISI marked, IS 14846, pressure PN 1.6 with brass spindle with clamps and check nuts, operating hand wheel including dismantle and remove the unserviceable sluice valve complete all as specified and directed. 18 All as per Srlitem No. 17 but 100mm bore complete all as specified and directed. 19 All as per Srlitem No. 17 but 150mm bore complete all as specified and directed. 20 Supply and fix Dual plates CI wafer type Non Return / Check Butterfly valve, 100 mm bore tested to pressure of 15Kg/Sqcm flanged type including necessary heavy duty gasket, G I Bolts, G I Nuts, G I Washers etc. incl taking down old u/s complete all as specified and directed. 21 All as per Srlitem No. 20 but 150mm bore complete all as specified and directed. 22 M&L for dismantling of defective 80 mm dia sluice valve for repairssuch as repacking stuffing box of sluice valve spindle, refacing, grinding, stuffing and threading of spindle, replacement of worn out check nut, repairs to gate assembly replacement of jointing materials such as rubber sheets, nuts, bolts & washers, gland rope and refixing in its original position, testing on completion etc. complete all as specified and directed. 23 All as per Srlitem No. 22 but 100mm bore complete all as specified and directed. 24 All as per Srlitem No. 22 but 150mm bore complete all as specified and directed. 25 S&F and testing, 20 mm bore, gun metal gate valve / ball valve, ISI marked, hand lever / iron wheel head operated, screwedat both ends for iron pipes and fixed including taking down of old unsv gate valve complete all as specified and directed. 26 All as per Srlitem No. 25 but 25mm bore complete all as specified and directed. 27 All as per Srlitem No.25 but 40mm bore complete all as specified and directed. 28 All as per Srlitem No.25 but 50mm bore complete all as specified and directed. 29 S&F CPVC Ball valve 50mm OD alongwith necessary leak proof CPVC paste / gum incl taking down old u/s complete all as specified and directed. Make Astral / Supreme / Finolex 30 All as per Srlitem No.29 but 40mm bore complete all as specified and directed. 31 All as per Srlitem No.29 but 32mm bore complete all as specified and directed. 32 All as per Srlitem No.29 but 25mm bore complete all as specified and directed. 33 Supply & laying in trenches / floor or fixed to wall / roof using suitable size MS Clamps duly painted, CPVC pipes SDR 11 and incl plain CPVC SDR 11 fittings of size 50mm OD alongwith necessary leak proof CPVC paste / gum incl taking down old u/s complete all as specified and directed. 34 All as per Srlitem No.33 but 40mm bore complete all as specified and directed. 35 All as per Srlitem No.33 but 25mm bore complete all as specified and directed. 36 M&L for repair / rectification of leakages in water supply distribution GI lines of 20 to 25 mm dia incl necessary excavation, returning filling as per site requirement, tightening of loose joints of GI unions, elbows, sockets, tees etc. cutting / threading if required all as directed.Note:The complaints for the above work are to be collected by the contractor rep from MES maint incharge of EBS Babugarh on daily basis and trades men are to be detailed immediately. Required stationery such as complaint register, Job cards etc shall be arranged and maintained by the contractor. Transport and Tools required for attending the complaints are to be arranged by the contractor. 37 All as per Srlitem No.36 but GI tubing 40 to 50 mm dia complete all as specified and directed. 38 M&L for attending break down of water supply pipe line and repair to CI / DI water mains of size 80 mm to 150 mm dia at a given notice including necessary excavation, earth work by manual or using special T&P such as JCB etc. dewatering from the trenches by using pumps or any other mode, rectification of leakages, fixing of CI specials such as collars bends / tail peaces / D-clamp joints etc. and arresting the leakage, testing all as directed. Note: Specials, joint materials only measured and paid separately. 39 M & L for Construction of brick masonry valve chamber of size 1000 x 1000 x 1000 mm (Internal dimenssions) with PCC foundation 1:4:8 type D2 using 40 mm graded stone aggregate 150 mm thick, 150 mm wide off sets allround over 100 mm thick hard core, brick masonry walls built in CM 1:6, 50 mm thick PCC 1:2:4 Type B1 coping finished even and smooth, rendering 10 mm thick in cement mortar (1:6) finished even and smooth, with out using extra cement internally and 150mm below GL externally and top of floor including excavation, earth work in soft / loose soil, 5 mm thick MS sheet cover fixed on 50 mm x 50 mm x 6 mm thick angle iron frame with hold fasts embedded in PCC coping with locking arrangement, mild steel handle and painting to steel surfaces with two coats of synthetic enamel paint over one coat of red oxide primer including disposal of surplus soil to a distance not exceeding 50 m etc. complete all as specified and directed. 40 All as per Item No. 39 but of size 600x600x600 complete all as specified and directed. 41 M&L for cleaning of 100000 Gallon RCC over head reservoir of any type, any height using construction of staging or by mechanical means for carrying out the inner surface of the walls and ceilings of the tank shall be cleaned with high pressure jet pump after emptying the water in the tank. After thorough cleaning of the tank, the cleaning water and sludge is to be removed by using pump and the sludge has to be disposed off at a place as directed. After removing thesludge from tank, the tank shall be cleaned thoroughly by using high pressure water pump first and again cleaned the tank by using high pressure vaccume pump and after removing the sludge / dirt completely from the tank the floor and inner surfaces of the tank shall be cleaned by using a industrial vaccum cleaner and the tank shall be made fully dust free. After made the tank dirt free the inner surfaces of walls and ceiling of the tank shall be treated with anti bacterial agents. After the treatment as mentioned above, the inner surface of walls and ceiling shall be treated with UV Radiator. After complete treatment is carried out, the all pipes inlet, over flow, delivery, wash out, ladder and doors shall be painted with two coats of synthetic enamel black paint after thorough cleaning the surfaces and also the surfaces of sluice valves shall be painted with PO red paint and writing Capacity of tank, date of cleaning and due date of cleaning on wall as specified and as directed. Incl replacing of u/s wire mesh of ventilations of the tank with new mesh complete all as directed BY Engineer-in-Charge.Notes for item No : (1) The unit rate quoted deemed to be including draining of water with mechanical equipment and working in water and mud etc. (2) The unit rate quoted deemed to be include all safety precautions which shall be taken while working on RCC over head tank / under ground sump and contractor or his engineer shall be available during execution of the job. (3) Lightning arrangements if required to be provided by the contractor temporarily at his own arrangements and the amount quoted for that is deemed to be inclusive in the unit rate and electricity/ diesel shall not be provided by MES. 42 Disconnecting the suction and delivery pipe line and electric connections of submersible pump set 25 / 30 HP and removing it from its original position alongwith pipes and fittings carefully by using chain pulley and tripod, transporting the same to the authorised work shop for necessary maint / repairs and refixing the same in its original position after repairs by lowering along with pipes including connecting up of water and electric connections including testing andcommissioning complete all as specified. (Depth of bore welll is upto 50 Mtr). Note: Expendable stores like cotton waste / cleaning materials, lubricants, gland packing, metal filling, machining and transportation to and from site to work shop and labour element are deemed to be included in rate quoted. 43 M&L for rewinding ofthesubmersible motor with super enamelled Copper conductor of good quality, same gauge and same No. of turns as that of existing including tying the winding and connecting the coils and bringing the connections as that of existing complete all as specified including applying insulating varnish, heating and backing the windings thoroughly for submersible motor 25 / 30 HP capacity. 44 M&L for Opening theSubmersible pumpset up to 30 HP pump sets for inspection, repairs and reassembling the pump and motor as per the original assembly after repairs / replacing the worn out unserviceable parts with new parts as ordered, including cleaning replacing the minor items like packing bolts, nuts washers and MS clamps etc and applying one coat of approved hammertene spray paint on exposed steel surface, making the pump and motor fully serviceable and testing after refixing and commissioning all as directed for satisfactory operation on its full load. Note: Spare parts will be measured and paid under relevant item separately. All minor consumables / Eqpt / Tpt required shall be deemed as included in the rates quoted. 45 Supply only Motor bearing, bush complete set inlet/outlet side suitable for submersible pump set up to 30 HP capacity complete all as specified and directed. 46 All as per Srlitem No.45 but Impeller complete all as specified and directed. 47 All as per Srlitem No.45 but Pump NRV complete all as specified and directed. 48 All as per Srlitem No.45 but SS sleeves complete all as specified and directed. 49 All as per Srlitem No. 45 but Neck ring stage casing complete all as specified and directed. 50 All as per Srlitem No.45 but Sand guard complete all as specified and directed. 51 All as per Srlitem No.45 but Oil seal complete all as specified and directed. 52 All as per Srlitem No.45 but Bowel case complete all as specified and directed. 53 All as per Srlitem No.45 but stainless steel shaft of standard size complete all as specified and directed. 54 S&F in repairs, flexible submersible cable 3 core 10 Sqmm with stranded Copper conductor, 1100 volts grade,PVC insulated, PVC sheathed, connecting with necessary end ferrules / water proof joints complete all as specified and directed. 55 S&F in repairs, fully automatic star delta motor starter suitable for 25 / 30 HP submersible pumpset, 3 phase, 415 V with relay range of 45 to 75 Amps incl enclosure complete all as specified and directed. . Make - Havells/Schneider/L&T 56 Supplying, installing, erecting, testing and commissioning, factory made and tested, pump panel board outdoor type, dimensions not less than 1.0 m (L) X 0.5 m (W) X 1.2 m (H), suitable for 3 phase, 415 Volts, 50 Hz system with 200 Amps capacity aluminium bus bar. The panle should be dust and vermin proof, IP 56 class protection and made of 3.15 mm thick CRCA MS sheet with doble door, both sides openable inclusive of locking arrangement, suitable opening for vent and cable entry consisting of Electronic fully automatic star delta starter-01 No. having automatic phase sequence corrector, programmable time with input supply by MCCB of 100 Amps rating, digital type Ammeter and Voltmeter, selector switch, CTS, RYB including indication lampsetc, suitable for submersible pump-motor set of size 25/30 HP, erected on 50X50X6mm thick angle iron frame work, bottom channel of size: 70X40X5 mm powder coated finish over one coat of red oxide primer outside and two coats of red oxide primer on inside , grouted in floor including complete earth work such as excavation, removing and returning filling and required PCC work for the erection of the panel board, complete all as specified and as directed. 57 S&F in repairs, Pressure Gauge, 100mm dia, 0 - 14 Kgs rating complete all as specified and directed. 58 Supply of Calcium hypochlorite having 65% to 70% strength chlorine for disinfection purpose in white coloured powder form for water treatment in sealed non returnable containers in the store yard of EBS Babugarh complete all as specified and directed. Make- RENSA/Purichlor 59 M&L for repairs of dosing system consisting of Syntex make 100Ltr capacity poly Ethelene (PE) tank, Fibre reinforced plastic (FRP) lid have port hole for pouring calcium based granual disinfectant chemical and water when necessary and operatedwith 1 phase motor , 240V complete to the satisfactory operation of the system complete all as specified and directed. 60 M&L for the existing Microprocessor based circuit type water level device consist of seven segment 2 LED display fitted in the control panel operated the pump to automatic switch off when the water level in OH tank reaches the maximum level, visual display with audio alarm on low water level in tank complete to the satisfactory operation of the system complete all as specified and directed. 61 M&L for Structural Steel Work, made out ofFe 410-W (Gde-E-250) quality-A Rolled Mild Steel Channel, Angle or Tee Sections, MS sheet with hinges & locking arrangementsetc. cut to shape / ordinary length, drilled and countersunk for Screws / Bolts, including bending and welding duly painted with 2 coats of Anti Corrossive Synthetic enamel paint over a coat of Zinc Chromate complete all as specified and directed. 62 M & L for carrying out B check of 320 KVA DG set through authorised service dealer of the manufacturer including replacement of B check service kit complete all as per manufacturers standards complete all as specified and directed. 63 All as per Srlitem No.62 but for 50 KVA DG set complete all as specified and directed. 64 All as per Srlitem No.62 but for 15 KVA DG set complete all as specified and directed. 65 M&L for draining out old engine oil, S&F Engine lubricanting oil conforming to the engine manufacturer requirement of classification SAE 15 W 40 lube oil complete all as specified and directed.Make : Servo / Castrol 66 M & L for Overhauling of radiator including dismantling from engine,opening of radiator, cleaning of radiator tubes, fans with acid and removing the scaling & dust, brazing the copper tubes, arresting the leakages completely etc, including renewal of all connecting parts i.e. radiator hose pipe with clamps, bolts, nuts, washers, rubber bush packing material, etc. and re assembling the radiator and fixing with DG set properly in original position, checking the alignment, making proper hose connection, testing for smooth operation complete all as directed for DG set of any type/make having capacity of 320 kVA.NOTE: The cost of renewed parts is deemed to be included in unit rate quoted by contractor. No extra cost shall be paid to the contractor for the same. 67 All as per Srlitem No.66 but for 50 KVA DG set complete all as specified and directed. 68 All as per Srlitem No.66 but for 15 KVA DG set complete all as specified and directed. 69 M&L for taking out injector of DG set of capacity 320 kVA, disconnection and opening of fuel injector assembly, carrying complete overhauling/servicing of fuel injector system, including replacement of injector kit, checking of pressure, complete for each injector and reassembling the same in original positionby making proper fuel connection and testing for smooth operation complete all as specified and directed.Note: Cost of renewal of parts to be measured and paid separately. 70 Supply only nozzle holder for 320 kVA DG set of any make complete all as specified and directed. 71 M&L for opening /taking out fuel injection pump (FIP) of DG set of any type/make of capacity 320 kVA, disconnecting of fuel injector line, carrying out complete overhauling servicing of injector pump, calibration of fuel pump as per manufacturer instruction, assembling of the same wit DG set properly in original position, checking the alignment, making proper fuel connection including renewal of unserviceable/defective minor parts like seal O ring, fuel pump gasket, gear, technometer, bushing, technometer cover, fuel pump, gear housing, fuel pump gear, etc. and testing for smooth operation complete all as directed after renewal of following major parts if found defective/unserviceable.NOTE: The cost of renewed parts is deemed to be included in unit rate quoted by contractor. No extra cost shall be paid to the contractor for the same. 72 Supply only Plunger and return spring for 320 kVA DG set of any make/type complete all as specified and directed. 73 Supply only control rod for 320 kVA DG set of any make/type complete all as specified and directed. 74 Supply only Plunger barrel for 320 kVA DG set of any make/type complete all as specified and directed. 75 Supply only delivery valve and spring for 320 kVA DG set of any make/type complete all as specified and directed. 76 Supply only HP line for 320 kVA DG set of any make/type complete all as specified and directed. 77 Supply only pump element for 320 kVA DG set of any make/type complete all as specified and directed. 78 Supply only roller tappet for 320 kVA DG set of any make/type complete all as specified and directed. 79 Supply only nozzle for 320 kVA DG set of any make/type complete all as specified and directed. 80 Supply & fix flexible coupling for 320 KVA DG Set including alignment of alternator with engine complete all as specified and directed. 81 All as per Srlitem No.80 but50 KVA DG set complete all as specified and directed. 82 All as per Srlitem No.80 but 15 KVA DG set complete all as specified and directed. 83 M & L for alternator servicing, decarbonising the alternator coils, re-varnishing, heating, bearing checking, re-greasing and termination, tinning for 320 KVA DG Set complete all as specified and directed. 84 All as per Srlitem No.83 but for 50 KVA DG set complete all as specified and directed. 85 All as per Srlitem No.83 but for 15 KVA DG set complete all as specified and directed. 86 Supply and filling coolant of superior quality complete all as specified and directed. Make Servo / Castrol 87 M&L for cleaning of diesel tank of DG Set 320 KVAincluding replacement of worn-out pipe line and measuring scale and fixing in original position and make it leak proofwith necessary clamps complete all as specified and directed. 88 Supply and fixing battery 12V 180 AH including replacement of terminals and connecting lead suitable length and size of multi stranded copper wire complete all as specified and directed. .Make:- Exide/Amaron 89 All as per Srl item No.88 but 12V,100 AH complete all as specified and directed. 90 Dismantling of burnt/defective wiring system of DG Set 320 KVA and M&L for complete wiring of required size with sleeves thimbles, lugs etc for DG set complete all as specified and directed. 91 All as per Srlitem No.90 but for 50 KVA DG set complete all as specified and directed. 92 All as per Srlitem No.90 but for 15 KVA DG set complete all as specified and directed. 93 Disconnection and taking out the unserviceable turbo charger assembly of DG Set 320 KVA and taking to workshop, strip opening of turbo charger and replacement of repair kit, re-assembling and fixing back to engine and testing complete all as specified and directed. 94 All as per Srlitem No.93 but for 15 to 50 KVA DG set complete all as specified and directed. 95 M & L for servicing, repairing, maintenance of self starter assembly of DG Set 320 KVA, complete with replacement of switch magnet,bush gear, O ring assembly, bush set, sealing kit, clutch assemble with new ones and refixing the same in original positioncomplete all as specified and directed . NOTE: The cost of replacement of items mentioned in the description is deemed to be included in the rate quoted by the contractor and no extra payement will be done for replacing those items. 96 Supply only armature for 320 kVA DG setcomplete all as specified and directed. 97 Supply only solenoid switch for 320 kVA DG set complete all as specified and directed. 98 Supply only field coil for 320 kVA DG set complete all as specified and directed. 99 All as per Srlitem No 96but for 15 to 50 KVA DG set complete all as specified and directed. 100 All as per Srlitem No 97but for 15 to 50 KVA DG set complete all as specified and directed. 101 All as per Srlitem No 98 but for 15 to 50 KVA DG set complete all as specified and directed. 102 Supply & Replace Fan belt set of existing size complete of DG Set 320 KVAcomplete all as specified and directed. 103 All as per Srlitem No. 102 but for 15 to 50 KVA DG set complete all as specified and directed. 104 Supply & Replace Oil temperature gauge 0-130C complete all as specified and directed. 105 Supply & Replace Water temperature gauge 0-130C complete all as specified and directed. 106 Supply & Replace DC ammeter 0-50 complete all as specified and directed. 107 Supply & Replace Tachometer 0-2500 RPM complete all as specified and directed. 108 Supply & Replace Ignition switch DC with Key complete all as specified and directed. 109 Supply & Replace Oil pressure gauge 0-7 Kg/Cm complete all as specified and directed. 110 Supply & Replace Distilled Water complete all as specified and directed. 111 Supply & Replace Battery lead terminals complete all as specified and directed. 112 S & F automatic battery charger for 12/24V battery complete with all necessary controls and fixing arrangments complete all as specified and directed. 113 S&F in replacement of DG set door lock with handle with double key of all doors of DG set canopy of any capacitycomplete all as specified and directed. 114 S&F in replacement of Automatic voltage Regulator (AVR) suitable for DG Set of320 KVAcapacity with and including taking out old AVR and making all connectiontesting for smooth operation complete all as specified and directed. 115 All as per Srlitem No above here-in-before butfor 50 KVA DG set complete all as specified and directed. 116 Supply, fixing & testing Volt meter 0-500 Volts, 96mm x 96mm, digital type complete all as specified and directed. Make : AE/ Rishab/Meco/Enercon. 117 Supply, fixing & testing Ammeter 0-400 Amps, 96mm x 96mm, digital type complete all as specified and directed. Make : AE/ Rishab/Meco /Enercon. 118 S&F in repairs, thermal over load relay of various ranges starting from 3 Amps to 15 Amps complete all as specified and directed. Make : Type ML0 to ML 1.5 of L&T /BCH/ C & S Electric / Siemens. 119 S&F in repairs, thermal over load relay of various ranges starting from 9 Amps to 42 Amps complete all as specified and directed.Make : Type ML2/ML3 of L&T or equivalent of BCH/ C & S Electric / Siemens. 120 S&F in repairs of single phase preventor, auxiliary volts 415 volts, suitable for 3 phase AC supply complete all as specified and directed. 121 S&F in repairs, testing push buttons with thermo plastic body actuators with carrier having flush type push button complete all as specified and directed.Make : BCH/C & S Electric /L&T / Siemens. 122 S&F in repairs, testing pilot lamps LED type with integral circuit & cluster LED suitable for operating at 240 /220 Volts complete all as specified and directed. Make : BCH/C & S Electric /L&T / Siemens. 123 Preparation of the existing surfaces of electric panels of any description and size & applying two coats of synthetic enamelled paint of approved shade complete including writing details & information on its panels with paints in the pattern & style to match with the words as existing all as directed. 124 M&L for preventive maintenance and servicing of AMF panel of any capacity DG set installed at site incl checking of connections of cables and tightening of loose wiring, nuts and bolts of panel andbus bar chamber. The cost includes minor items like replacement oflugs, control wiring and ferrules etc. complete all as specified and directed. 125 S&F in replacement, asbestos rope of 19 mm dia around of the exhaust pipe of diesel engine any cap complete all as specified and directed. 126 M&L for repair of burnt / perished cable ends on incoming and outgoing feeders of panel equipments and other machinery including cutting of burnt ends preparing / dressing of cables end crimp with suitable size of cable lugs (cable lugs will be measured and paid seperately) incl providing, fixing suitable nuts / bolts / washers etc. forupto 95Sqmm 3.5 core cable 127 All as per Srlitem No.1 but 120Sqmm to 240 sqmm 3.5 core complete all as specified and directed. 128 S&F Al lugs for cable size 50 to 70 sqmm complete all as specified and directed. 129 S&F Al lugs for cable size 95 to 120 sqmm complete all as specified and directed. 130 S&F Al lugs for cable size 240 to 300 sqmm complete all as specified and directed. 131 S&F in replacement,synthetic rubber insulated mats in replacement forinstallations size 2 mtr X 01 mtr X 2.5 mm thick, for voltage upto 11 kV, ISI marked, as per IS 15652-2006 complete all as specified and directed. 132 M&L for repairs of existing On Load/off load Change Over Switch, 4P, 400 Amps, 415 volts by cleaning/ decarbonising,replacement of worn out contacts,lugs and handle arrangement to the smooth function of the item complete all as specified and directed. 133 S&F in repairs of Off load change over switch 4 pole, 415V, AC , 100 A rating with enclosure type complete all as specified and directed. . Make- HPL 134 S&F in repairs, connect,MCCB 4 Pole, 415V, adjustable type, 400 Amps,breaking capacity of 36 KA with cable separators complete all as specified and directed. 135 All as per Srlitem No.9 but 200 Amps, 36KA complete all as specified and directed. 136 All as per Srlitem No.9 but 160 Amps, 36 KA complete all as specified and directed. 137 All as per Srlitem No.9 but 100 Amps, 16 KA complete all as specified and directed. 138 S&F in repairs, connect,MCCB 3 Pole, 415V, 125 Amps, 16 KA complete all as specified and directed. 139 All as per Srlitem No.13 but 63 to 100 Amps, 16KA complete all as specified and directed. 140 Testing and calibration of HT VCB 11 KV complete with primary and secondary test as required including checking of wiring of all electrical measuring instrument and resetting of relay and proper alignment mechanical system for smooth functioning and tripping at any type offault developed in feeders complete all as specified and directed by Engineer-in-Charge. Note:Contractor will submit primary and secondary test record at the time of calibration of HT VCB, duly signed by the technical rep of manufacturer/authorised dealer to Engineer in Charge. The rate quoted by the contractor shall be deemed to include the cost of this provision incl T&P required for injecting regulated high current. 141 Disconnecting of HT supply from 11 KV VCB of any make/type/capacity for repair works, servicing and taking out trolley with completedecarbonizing the contactpoints, cleaning with CRCsolution and inner body clean with vaccum cleaner etc and incl replacement of defective minor parts like lugs, terminals, ferrule,control wiring, nut bolts, HRC fuse links etc found during servicing. Reassembling and testing of relays for trippingtime setting over current setting, earth fault setting etc including checking of vaccume interrupter, tripping mechanism etc after servicing complete all as specified and directed by Engineer-in-Charge. 142 M&L for servicing/repair of VCB spring charging motor 24/220 Volt DC/AC for 11KV VCB, of existing make, type, size, capacity with driving gear including ensuring the manual operation of charging complete testing to the satisfactory operation of VCB charging complete all as specified and directed. Note: (1) HT VCB above servicing shall be carried out only by qualified and experienced person and prior approval shall be obtained from GE.(2) The major spare parts required during above servicing will be measured and paid separately under relevant item of schedule. 143 Supply only open/closed auxiliary contacts suitable for upto 630 Amps HT VCB fixed in repairs. As per existing sample. 144 Supply only under voltage release suitable for upto 630 Amps HT VCB fixed in repairs. As per existing sample. 145 Supply only under/over frequency release suitable for upto 630 Amps HT VCB fixed in repairs. As per existing sample. 146 Supply only Shunt trip closing coil assembly 110/220 volts, DC/AC suitable for upto 630 Amps, HT VCB complete all as specified and directed. 147 Supply only Shunt trip tripping coil assembly 110/220 volts, DC/AC suitable for upto 630 Amps, HT VCB complete all as specified and directed. 148 Supply only spring charging Motor Cut off switch as per existing samplesuitable for 11 KV VCB complete all as specified and directed. 149 M&L for cable jointing kit for 11 KV (Earthed) grade for indoor terminations heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120sqmm to 185 sqmm incl taking out old jointing kit of any make and type complete all as specified and directed. 150 All as per Srlitem No.149 but out door type of size 120 to 185 sqmm HT cable complete all as specified and directed. 151 All as per Srlitem No.149 but out door type of size 95 sqmm HT cable complete all as specified and directed. 152 M&L for cable jointing kit for 1100 volts grade (LT cable) for outdoor terminations heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 240 sqmm to 300 sqmm incl taking out old jointing kit of any make and type all as specified and directed. 153 All as per Srl item No. 152 but for LT cable of size 120 sqmm to 185 sqmm complete all as specified and directed. 154 M&L for laying in repairs of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured electric power cables (heavy duty) with aluminium conductor, 11000 volts earthed grade of size 95 sqmm 3 core cable laid in trenches/ ducts or fixed to walls / poles or passed through pipes all as directed. 155 All as per Srlitem No.154 but out door type of size 3 core x 120 sqmm complete all as specified and directed. 156 Supplying laying and testing XLPE insulated ,armoured , electriccable (heavy duty)1100 volt grade with stranded aluminium conductor, laid in trenches / ducts or fixed to walls / poles or passed through pipesscomplete all as specified of following sizes :- 157 All as per Srl item No.156 but 240 Sqmm, 3.5 core cable complete all as specified and directed. 158 All as per Srl item No.156 but 120 Sqmm, 3.5 core cable complete all as specified and directed. 159 All as per Srl item No.156 but 95 Sqmm, 3.5 core cable complete all as specified and directed. 160 All as per Srl item No.156 but 70 Sqmm, 3.5 core cable complete all as specified and directed. 161 All as per Srl item No.156 but 50 Sqmm, 3.5 core cable complete all as specified and directed. 162 All as per Srl item No.156 but 35 Sqmm, 3.5 core cable complete all as specified and directed. 163 All as per Srl item No.156 but 25 Sqmm, 3.5 core cable complete all as specified and directed. 164 All as per Srl item No.156 but 16 Sqmm, 4 core cable complete all as specified and directed. 165 All as per Srl item No.156 but 10 Sqmm, 2 core cable complete all as specified and directed. 166 All as per Srl item No.156 but 6 Sqmm, 2 core cable complete all as specified and directed. 167 M&L for fixing PCC cable route markers of size 700X240X75 mm at top of cable trench complete all as specified and directed. 168 Supply and spreading clean fine dry river sand in trenches for cushioning of under ground cable/ cable duct or inside the premises of transformer yard complete all as specified and as directed. Note: Only punned thickness shall be measured for payment purpose. 169 M&L for laying burnt clay fly ash old size bricks, straight or curved on plan, laid flat with width equal to length of brick, laid dry over under ground cable for protection complete all as specified and as directed. 170 M&L for Galvanized steel tubing, light grade, with all fittings for protection of cable including taking down old, rusted & corroded unsv Galvanized steel tubing complete all as specified and as directed of the following sizes:- 171 100mm bore complete all as specified and directed. 172 80mm bore complete all as specified and directed. 173 50mm bore complete all as specified and directed. 174 40mm bore complete all as specified and directed. 175 M & L for cutting hard standing/ Road cutting for taking up or laying of LT UG cable upto a depth of 15 cm and after laying of cable, well ramming to the excavated soil and repair the cutting/ exvcavated portion of road as existing or by providing suitable mixture of PCC complete all as specified and as directed. 176 M&L for providing PCC 1:4:8, type D-2, (using 40 mm graded stone aggregate) as in foundation for erection of poles complete inclding breaking and removing the old concrete complete all as specified and as directed. 177 M&L for providingPCC 1:2:4, typeB-1 (using 20 mm graded stone aggregate) as incoping to pole etc., including breaking and removing the old concrete and providing necessary form work complete all as specified and as directed. 178 M&L for lightning arresters expulsion type complete with all fittings, transmission class, max discharge capacity 65 kA suitable for 11000V grade including taking down existing unsv damaged lightening arrestor complete all as specified and as directed. 179 M&L for switch air break, gang operated, triple pole, mechanically operated, vertical/ Horizontal out door type, mounted on insulators and steel frame with operating mechanism worked from ground level for current rating upto 400 Amps suitable for 11000 volts grade complete all as specified and as directed. 180 M&L for 11000V grade, expulsion type fuses, single pole, mounted on insulators and steel frame of current rating 50 Amps including taking down old unsv expulsion fuse unit complete all as specified and as directed. 181 Surface excavation not exceeding 30 cm deep and averaging 20 cm deep and getting out in soft/ loose soil, removing of bushes, roots etc., in the transformer/ sub station yard and surrounding of two or four pole structres, treating the excavated area with anti vegetation growth chemicals, complete all as specified and directed. 182 M&L for loose filling with aggregates of gauge 40 to 80 mm of broken stone or boulders, deposited, spread and levelled in layers not exceeding 20 cm thick, watered and rammed to a true surface of transformer/ sub station yard and two pole / four polestructure complete all as specified and as directed. 183 Isolating the transformer/ voltage stabilizer by carefully dismantling the HT / LT and earth connections, draining out the oil from transformer to the required level and storing in cleaned container, opening the top cover of transformer/ voltage stabilizer and conservator tank from transformer, rectifying the defects and dismantling & replacing burnt out LT/ HT bushes, making all HT / LT connections as per the original, re-filling the transformer oil to the required level, replacing required oil seals & top cover gasket including replacing rusted unsv nut, bolt & washers and testing on completion and refixing the same for capacity upto 250 KVA complete all as specified and as directed. NOTE: (1) LT/ HT bush, transformer oil for topping up and gasket will be measured and paid separately as supply only items under relevant items of schedule 184 Disconnecting the HT/ LT connection, taking out the transformer/ voltage stabilizer from its plinth at any situation with the help of suitable crane and transporting the transformer/ voltage stabilizer to workshop for carrying out necessary repairs and bringing back and re-install in its original place of capacity upto 250 KVA complete all as specified and as directed. 185 Taking out complete core from transformers/ Voltage stabilizer of capacity upto 250 KVA cutting and removing burnt out copper/ aluminium winding and re-winding the same with super enamelled copper conductor of existing gauge togetherwith insulatingmaterials, applying varnish, drying in heating chamber, re-assembling the transformer as per the original and testing on completion complete all as specified and as directed. NOTE: Shifting of transformers/ Voltage stabiliser from installed position to civil workshop and back will be measured and paid separately under relevant items. 186 M&L for transformer/ voltage stabiliser oil filtration for removing sludge, dust, dirt and moisture from the oil, with the filtered oil having breakdown voltage (BDV) greater than 30 kV (avg) at 2.5 mm gap. NOTE: Contractor will submit BDV test value of the filtered oil after the filtration process duly signed by the technical rep of the manufacturer/authorised dealer to Engineer in Charge. The cost of this provision incl required T&P for getting the oil tested for BDV value is deemed to be included in the rate quoted by the contractor. 187 Supply only transformer oil for topping up in transformers/ Voltage stabilizer complete all as specified and as directed.. Make:Poweroil/Transol GET complete all as specified and directed. 188 Supply only bush of capacity 100 KVA Transformer 11KV/433V type complete all as specified and directed. 189 Supply only bush of capacity 250 KVA transformer 11KV/433V type complete all as specified and directed. 190 Supply only silica gel complete all as specified and directed. 191 M&L for silica gel breather and oil cup, including sufficient quantity of silica gel along with oil filling in the cup if oil level in the cup is not up to the mark, complete all as specified and as directed for thefollowing capacities of transformer:- NOTE: The cost of oil is deemed to be included in the rate quoted by the contractor. 192 Transformer of capacity 100 KVA complete all as specified and directed. 193 Transformer of capacity 250 KVA complete all as specified and directed. 194 M&L for preparation of old painted surfaces of HT 11 KV four pole structure and painting with two coats of aluminium paint over a coat of red oxide primer on all steel surfaces such as poles, channels, angles and clamps of any description and providing 04 Nos bands/ straps with synthetic enamel paint (black and white 30 cm wide each) from top of plinth block complete all as specified and as directed.. 195 All as per item No. abovehere-in-before but of two pole structure complete all as specified and directed. 196 Dismantling damaged steel tubular poles/ struts of any size complete complete all as specified and as directed. 197 M&L for erection of steel tubular, swaged poles complete with cast iron base plate of size 300 x 300 mmfinial taper plug, cap, bolts, nuts, washer and screws as specified confirming to IS type 410 SP-31 (9 M long), providing through hole of 14 mm diameter at a height of 300 mm above the planting depth for earthing arrangements, inclusive of coated with two coats of black bituminous paint throughout internally and externally up to the planting depth and the remaining portion of the exterior shall be painted with two coats of silver aluminium paint over one coat of red oxide primer complete all as specified and as directed. (Note : Excavation, earth work, PCC foundation, coping shall be measured and paid sepearately under relevnt items). 198 M&L for erection of steel tubular, swaged poles complete with cast iron base plate of size 300 x 300 mmfinial taper plug, cap, bolts, nuts, washer and screws as specified confirming to IS type 410 SP-55 (11 M long), providing through hole of 14 mm diameter at a height of 300 mm above the planting depth for earthing arrangements, inclusive of coated with two coats of black bituminous paint throughout internally and externally up to the planting depth and the remaining portion of the exterior shall be painted with two coats of silver aluminium paint over one coat of red oxide primer complete all as specified and as directed. (Note : Excavation, earth work, PCC foundation, coping shall be measured and paid sepearately under relevnt items). 199 M&L for fixing stay assembly having 20 mm diameter of stay rodincluding loop type insulator, stay clamps, etc complete with accessories as shown in electrical plate No. 1 (Excavation and Concrete work will be measured separately) complete all as specified and directed. 200 Releasing the binding of ACSR conductor of LT/ HT OH lines comprising 3 Phase 3/ 4 wire or single phase 2 wire inclduing street light conductor & earth wireof line from insulator, removing the jumper, connector, service wire, disconnecting the connection of UG cables and restreching & stringing of existing LT/HT OH lines, any size, length and span upto desired sag and rebinding the ACSR conductor on insulator, reconnecting the UG cable etc with and including suitable binding/ jumper material with aluminium wire and trimming the tree branches upto 1.5m distance around conductor to make the line functional complete all as specified and as directed. . Note: (a) Jumper/ binding material shall be deemed incldued in the rate quoted by contractor. (b) Trimming of tree branches shall be measured and paid separately under relevant items. (c) Any type conductor and any number of runs between the poles shall be measured as one span for the purpose of payment. 201 Material & Labour for attending break down/ emergent repair immediately on intimation and rectify the External electric supply complaint on LT/HT overhead lines/ under ground cable alongwith necessary T&P, safety devices etc. as per site requirement complete all as specified and as directed for the following:- 202 M&L for jointing of LT/ HT OH line in case of breaking of conductor and refreshing of wornout jumper by suitable jumper/ binding materials complete all as specified and directed. 203 Disconnecting worn out under ground cable from over head conductor, cutting down worn out portion of under ground cable of any type and size for repairs and taking out under ground cable loop from ground by excavating and all neccessary earth work and making fresh connection for restoration of electric supply complete all as specified. Note: Excavation, earth work, taking out cable protection covers, & sand cushion and relaying the same shall be deemed incldued in the rate quoted by contractor 204 Disconnecting worn out under ground cable of any type and size from main switch board/ any type of switch gear system including change over switch etc. for repair and taking out under ground cable loop from ground by excavating and all necessary earth work and making fresh connection by proving suitable size of lugs for restoring of electric supply complete all as specified. Note: Jointing material, Lugs etc and Excavation, earth work, taking out cable protection covers, & sand cushion and relaying the same shall be deemed included in the rate quoted by contractor 205 M&L for ACSR conductor in OH lines of HT/ LT/ street light conductor (Squirrel/ Weasel) including jumper and binding material with aluminium wire complete all as specified and directed. 206 M&L for cradle guard, hexagonal/ rectangular or as per existing shape fabricated with galvanised steel wire 4 mm dia including binding the gaurds with cradle supproting GI wire inclduing taking down existing unsv gaurd wire complete all as specified and as directed. 207 M&L for trimming of tree branches around HT / LT overhead lines including cutting and removing any foreign material like bushes or shurbs complete and removing the trimmed/ cut down branches/ bushes/ shrubs and depositing where directed at a distance not less than 100m complete all as specified and as directed.Note:- (a) The item will be measured in span length. The approx span length is 35M to 50M. (b) The cost for T&P and transportation required shall be deemed included in the rate quoted by contractor. 208 Supply and replace PVC spacers suitable for 2 wire sagged ACSR conductor complete all as specified and as directed. 209 Supply and replace PVC spacers suitable for 4 wire sagged ACSR conductor complete all as specified and as directed. 210 M&L for Pin type, porcelain, vitreous, white, brown or green insulators including one galvanised mild steel spindle, two galvanized iron washers and one galvanized iron nut, 100 mm height, 65mm dia for 1100 volts grade complete all as specified and as directed. 211 All as peritem no. 88 but height 150mm, dia 150 mmm for 11000 volts grade complete all as specified and directed. 212 M&L for shackletype, porcelain, vitreous, white, brown or green insulator includinggalvanised mild steel straps,washers, insulator bolts andnuts, of size 100 mm height, 115mm dia for 1100 volts grade complete all as specified and as directed. 213 All as peritem no. 193 above but size 150mm height,and dia 150 mm for 11000 volts grade complete all as specified and directed. 214 S/F in repairs, 1100 volts grade heavy duty PVC sheathed stranded Aluminium conductor twin core cable flat or circular of size 6 Sqmm complete all as specified and directed. 215 All as per item No 195 above but 10 Sqmm size complete all as specified and directed. 216 M&L for cross arms, bracings, supports, clamps and back plates fabricated from structural steel section including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts in any shapes or size including painted with two coats of silver aluminium paint over one coat of red oxide primer complete all as specified and as directed. 217 Scraping, cleaning and preparation of old surfaces of steel tubular pole (9 Mtr long) steel fitting complete and M&L for painting with one coat for aluminium paint after preparation of the steel surfaces and then applied strap with two coats black & white paint in strap alternatively all round the poles from the bottom of the pole for indication of the poles. Height of the strap shall be 30cm and number of strap shall be 05 Nos and all as directed by Eng-in-Charge 218 S & F in repair MCB SP 6 to 32 A, AC, 240V, 10 KA, ISI marked, either B series or C series, complete all as specified and directed. 219 S & F in repair isolator DP 40 A, AC, 240V, 10 KA, ISI Marked complete all as specified and directed. 220 S & F in repair isolator 4P 63 A, AC, 415V, 10 KA, ISI Marked complete all as specified and directed. 221 Supplying, installing, commissioing and testing of LT switchgear panel board ( Kiosk) of size not less than 600mmx600mmx500mm,IP-55 (outdoor type) , 415 Volts, 50 Hz, AC supply, three phase and neutral ( 4 wire) ,200 Amps coloured horizontal tinned Aluminium bus bars , factory made out of 3.15mm thick MS sheetstructure mounted onrigid mild steel angle iron frame of 50mmx50mmx6mm with 400mm long extended legs grouting in PCC 1:2:4 type B1 of size 150mmx150mmx250mm , duly epoxy powder coated internally and externally with approved shade, rubber gasketted, hinged front double doorand back openable doors with proper locking arrangements for dust and vermin proof ,complete including adjustable thermal and fixed magnetic release MCCB 4 pole, 100 Amps, 415V,36 KA,50 hz-01 No (incoming),suitable size cable allay,lugs , glands and making connections/ wiring with suitable size SC PVC insulated copper conductor cableall as specified. 222 Earthing complete with galvanised MS earth plate of size 600 x 600 x 6mm thick burried directly in ground not less than 2.25 Mtr below ground level, earth plate paced on all side with charcoal mixed with salt to a thickness of 150mm in layers, connected by GI earth strip of size 32 x 6mm thick, soldered and revetted to earth plate. GI earth strip will be protected by using 40mm bore GI pipe (light grade) from test point to main board. The earthing includes PCC pit chamber, RCC pit cover and frame, watering pipe 20mm bore, funnel with wire mesh with necessary earth work including disposal of surplus soil to a distance not less than 50 Mtr etc complete all as specified and shown in electrical plate No 3 of SSR Part-I. (Note : Main earth lead beyond 7.5 metre measured and paid for separately). 223 Earthing complete with galvanised MS earth plate of size 600 x 600 x 6mm thick burried directly in ground not less than 2.25 Mtr below ground level, earth plate paced on all side with charcoal mixed with salt to a thickness of 150mm in layers, connected, soldered and revetted to earth plated / galvanised earth lead wire 4.0mm dia by means of bolts, nuts , check nuts and washers of galvanised iron or steel. GI earth wire will be protected by using 15mm bore GI pipe (light grade) from test point to main board. The earthing includes PCC pit chamber, RCC pit cover and frame, watering pipe 20mm bore, funnel with wire mess with necessary earth work including disposal of surplus soil to a distance not less than 50 Mtr etc complete all as specified and shown in electrical plate No 3 of SSR Part-I. (Note : Main earth lead beyond 7.5 metre measured and paid for separately). 224 Apply proper electric shutdown of the feeder, dismantle and taking down LED street / Security light fitting of any make or modelalongwith connecting cable from elevated height of pole or building for repair by changing LED drive of suitable capacity, thorough cleaning and refixing the same after necessary repairs on its own position connecting complete all as directed. Note:- Spares of security/street light fitting shall be measured and paid under relevent supply only items. Required T & P and labour is deemed to be included in the rate quoted. 225 Supply only LED Driver suitable for any make or model LED street / security light fitting of capacity 25to 35 Watts complete all as specified and directed. 226 All as per item No 206 above but for 36 to 45 Watts complete all as specified and directed. 227 All as per item No 206 above but for 60/72 Watts complete all as specified and directed. 228 Supply only PVC sheathed two core 2.50 Sqmm stranded Aluminium conductor cable flat or round complete all as specified and directed. 229 Supply and fix 35 watts , 230V AC outdoor type (IP-65/66 protection) LED integrated street/security light fitting with all accessories incl connections and testing complete all as specified and directed. 230 All as per item No 210 above but 70 watts LED fitting complete all as specified and directed. 231 Lowering of high mast light assembly from upto 16 Mtr high mast, any make / model, dismantling, checking the serviceability and make the light fittings operational to give rated illumination incl cleaning the glass cover and refixing the same after repair / replacement of defective components complete with necessary electrical connection incl provision of two core 2.5 Sqmm PVC cable with multi stranded Copper conductor of required length, testingcomplete all as directed. Note: Flood light fitting shall be measured and paid separatelyunder relevent item. The cost of greasing of pully, roller, bearing and gear incl refixing of rope clamps , adjustment of lock, leaver, requried T & P and labour etc is deemed to be included in the quoted rate 232 Supply only LED flood light 120 watt, 230V, AC out door type with IP-66 protection with impact and corrosion resistant complete with driver complete all as specified and directed. 233 S&F LED post top light fitting IP 65 rated 20watt to light up parks, gardens and heritage sites complete all as specified and directed. 234 S&F LED bollard pressure diecast powder coated housing with PC diffuser, efficient high output LED 10 wattwith IP 65 protection complete all as specified and directed. 235 S& F in repairs and connect of solar LED street light fittings 20 watt with 40 AH battery bank, PV solar panel fitted on and incl 5 mtr steel pole with base plate incl foundation bolts, braket, clamps , nuts etc complete all as specified and directed. Note- Necesssary excavation/earth work , PCC/RCC work will be measuered and paid under relevant item of schedule. 236 Taking down unsv street light loop-in and loop out box by disconnecting electrical connection and removing existing clamps, nuts, bolts, and washers and supply, fix and connect, factory made out door type syntex street light loop-in and loop out box comprising with suitable size of bus bar, insulators, connectors etc and with one C curve 6 Amp MCB SP, one PVC way connector etc. incl suitable size clamps, nuts, bolts & washers complete all as specified and directed. 237 S&F 3 core , strandedcopper conductor cable 1.5 sqmm, PVC insulated and PVC sheathed , 1100 Volts grade for making connections from junction box tostreet light fittings including PVC conduit of size 20mm dia including necessary clampscomplete all as specified and directed. 238 S/F and connect, factory made duly painted metallic weather proof enclosure street light panel timer unit outdoor type having one 40 Amps C curve MCB TPN, three phase 415 V 32 Amps power contactor, Automatic operation street light timing switch having lighting control (ON-OFF) through Astronomical Calculation of Sun rise / sun set by setting date, time and degree of longitude and latitude without separate light sensors etc. including necessary fixing arrangements, suitable size clamps, nuts, bolts & washers complete all as specified and directed.
Contract Date: Jan 29, 2026 Contract Value : 33.87 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 4
Uttar Pradesh View Result →
46.
Housing Urban and Rular Development #8549114 AOC
Construction of Model Storage Facilities for Seized Narcotics Drugs and Psychotropic Substances, Dhanbad-Earthwork in excavation in foundation trenches in ordinary soil (vide classification of soil item-A) and disposal of excavated earth as obtained to a distance upto 50 M. including all lifts, levelling, ramming the foudation trenches, removing roots of trees, shrubs all complete as per approved design, building specification and direction of E/l. 2 Extra for earth work in hard soil as per specification and direction of E/I (Vide classification of soil item_B) 3 Earth Filling in foundation trenches and plinth in layers not exceeding 150mm thick well watered, rammed, fully compacted and fine dressed with earth obtained from excavation of foundation trenches withina lead of 50Mand lift of 1.5M all complete as per building specification and direction of E/I. (mode of measurement compacted volume) 4 Supplying and stacking of good earth at site including royalty and carriage upto 5 k m lead complete (earth measured in stacks will be reduced by 20%for payment). 5 Providing coarse clean sand in filling in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including cost of all materials, labour, royalty and taxes all complete as per building specification and direction of E/l (Mode of measurement complacted volume). 6 Providing designation 75B one brick flat soling joints filled with local sand including cost of watering taxes royalty all complete as per building specification and direction of E/l. 7 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering .all work up to plinth level:1:2:4 (1Cement ;2 coarse sand (zone-III):4 grade stone aggregate 20 mm normal size) 8 Providing and laying damp-proof course 50 mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 12.5 mm nominal size). 9 Providing designation 75 B brick work in C.M. (1:6) in foundation and plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth, curing, taxes and royalty all complete as per building specification and direction of E/l. 10 Providing designation 75B brick work in C.M. (1:3) in superstructure with approved quality of clean coarse sand of F.M. 2 to2.5 including providing 10 mm thick mortar joints cost of screening materials , scafolding , raking out joints to 15mm depth curing, taxes and royalty all complete as per building specification and direction of E/l. 11 Providing and laying in position specified grade ofreinforced cement concrete,excluding the cost of centering,shuttering ,finising and reinforcement- all work up to plinth level,1:1.5:3(1 cement : 2 coarse sand: 4 graded stone aggregate 20mm normal size). 12 Reinforced cement concrete work min wall (any thikness), including attached pilasters,buttresses,plint and string courses,fillets,column,pillars,piers,abutments,posts and struts etc. above plint level up to floor five level, excluding cost of centering, shuttering ,finishing and renforcement: 1:1.5:3( 1 cement : 1.5 coarse sand (zone-III) :3 grade stone aggregate 20 mm normal size). 13 Reinforced cement concrete work in beam, suspended floors,roofs having slope up to150 landings,balconies,shelves, chajjas,lintels, bands, plain window sills,staircases and spiral stair cases above plinth level up to floors five level,excluding the coast ofcentering,shuttering,finishing and reinforcement ,with 1:1.5:3(1 cement :1.5 coarse sand (zone III) :3 graded stone aggregate 20 mm normal size). 14 Centering and shuttering including strutting,propping etc.and removel of form for. 15 Foundation 16 Column 17 linten beams - 18 Roof slab 19 Providing, hoisting and fixing above plinth level up to floor five level precast Reinforced cement concrete in shelves, including setting in cement mortar 1:3 (1cement : 3 coarse sand), cost of required centering, shuttering and finishing with neat cement punning on exposed surfaces but , excluding the cost of reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III): 3 graded stone aggregate 20 mm nominal size). 20 Providing TMT reinforcement of 8mm dia rods as per approved -do-TMT Fe 500(only valid for tata,sail,jspl,electrosteel,bokaro and vizag) 21 Providing TMT reinforcement of 10mm, dia rods as per approved -do-TMT Fe 500(only valid for tata,sail,jspl,electrosteel,bokaro and vizag) 22 Providing TMT reinforcement of 12mm,16mm & 20mm dia rods as per approved -do-TMT Fe 500(only valid for tata,sail,jspl,electrosteel,bokaro and vizag) 23 Providing 12mm thick cement plaster (1:3)with clean coarse sand of F.M. 1.5 and including cost of screening, curingwith all leads and lifts of water, scaffolding, taxes and royalty all complete as per building specification and direction of E/I 24 Providing 12mm cement plaster (1:6) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I. 25 Providing 6mm thick cement plaster (1:4) in ceiling with clean coarse sand of F.M. 1.5 -do- 26 Providing 1.5 mm. cement punning including curing carrage of water withall leads and lifts as per buildingspecification and direction of E/I 27 Making 6mm X 6mm grooves in plaster surface over wall truely horizontal or vertical as specified at regular intervals at all heights including cleaning, finishing, scaffolding and curing with all leads and lifts of water all complete as per building specification and direction of E/I. 28 Water proofing for Old and New Roof Slab Providing and laying water proofing treatment on roof slab by applying two Component, factory designed, ready to use, acrylic modified flexible material applied wth brush, roller or spray for water proofing coating as Per ....Mier specificatIons with following steps (a)surface preparation -Providing and cleaning o1 concrete ...lece le remove dust, oil, grease including removal of existing loose paint r coating, and cement laitance by cleaning with comer..ed air 8 water let including all materials, labour, tools complete Ponding test to be done after plugging all outlets and to be checkedtrodentify seepage eakage On identification of seeps cem t be done with non shrink expanding admixt e a Ind, t 1MYK c g / Dr Fout/Fosroc or equive teems such as those betwe be chamfered with 15 1 41 admixed with ac Fixit or equivalent slum, of acrylic concretein baserovtartg and repaving of all c arapet wall and the roof slab et 50 mm fillet of mortar (Cement sand mer of Sika/ Fosroc/MYK SchomberglDr chamfering a prime coat shall be given with the Repairing surface irregularities, damaged ad cracks if any, with an acrylic polymer modified repair moile, including a coat of bonding agent of the same with cement slurry inctC01; all material, labour, tools complete (b)1st Coat - APOrlit coat of two component acrylic modified, ready to use. flexible come s material on surface saturated dry roof and inside wall of Par ll upto 600 mm by brush or roller After 1st coat re. pgplaisesd c@lot,h5t: kla9y,sw,nheincothaet rost, itahyee r of application , 45 still green 1st coat purpose of measure he entire treated surface will be measured 4, (c) 2nd Coat -To apply g02 coat of two component acrylic rnorAdmir* ready to use, flexible come tonal right angle to the 140,af,•:,-- over the glass fibre laid surface*d alepld be * applied VW Sgmt/coat For the purpose of rnikeSCiretfleritthe entireteaterfstiface will be measured After three days of drying the 2nd coat , the rain water outlets to be plugged and ponding test to be done for 48 hours to identify seepage, leakage from soffit and found necessary rectification to be done as per satisfaction of E/C The waterproof coating to be protected from damage before screed over it Water proofing Brand - Sika Topseal 109hi / Fosroc Brushbond RI. Dr Feet Picliflin 2K 1 MYK Actuate TG Product Performance Chemical Base F. A Acrylic copolymer, Part B: Specially graded cementitious powder -D011,4 1.6 fief, (mixed density) at 427°C Tensile Strength -2 N/mm2 atter 28 days (with Fibre cloth) (According to ASTM D 2370) Pullout Bond Strength -2 N/mm2 (concrete failure) (According to ISO4624) Slant-Shear Bond Strength -4 N/mm2 (According to FIP 5 15) Elongation at Break -35% without Fibre Cloth and 20% with Fibre Cloth (According to ASTM D 2370) (d) Protection of treated surface with PCC •- The treated surface should be covered with 25mm/50mm PCC of M-20 grade(1.1.5 3) with proper slope ( 1 120) towards the rain outlets in alternatepanels of 2 mt x 2mt keeping 6 mm gap between the panel joint Integral water proofing admixture conforming to IS 2645 @ of 100 ml per bag of of cement to be added in the screed concrete (paid separately for this items) All corners shall be chamfered with 150mm X 150 mm fillet The rainwater outlets shall be just leveled with the screed concre toe ure smooth discharge of water - the peripheral gaps be en p pi o and concrete surface should be packed pro with n c e and tiurpheral mouth to be sealed with ure Pvt Ltd. / MYK Schomb Fixit/Fosroc For the purpose of measurement the ed surface will be measured ensitive epoxy putty o (e)Groove of PC should be filled with Polysulphide Sealant. (Paid Separate* d - Sika India Pvt Ltd / MYK Schomberg / Dr FixitiFosroc W for five years 29 Covering of treated surface with PCC .- Providing 25 mm thick Cement Alf, Concrete M20 1:1. :3) maintaining slope in alternate 2 mt x 2 mt panels with aaprove. of stone chips of 20 mm to 6 mm size graded and cleaned sand 2.5 to 3 including screening,shuttering,and mixing cement concret . fixer with admixture of integral water proofing and placing in posi . ing curing,taxes and royality all complete as per building specifi nd direction of Ell. Panels that has been left shoul be casted next dysThere should be 6 mm gap between Panels .Brand Sika _Plastocrate Aus,MYK proof WP10, Fosroc- Conplast X421 lc& Dr Fixit Pidiproof LW+ 30 Providing and filling of 6 mm thick Groove between 25 mm PCC Panels with Polysulphide Sealant (Poring Grade)as Per drawings and technical specifications and direction of E in Charge (with 18% GST Polysulphicle Fosroc-Thoflex 600.Dr Fixit Pidiseal PS(42P) !MraYndK -Seikaal PS or Euivalent 31 Making plinth protection 50mm thik of cement concrete1:3.:6 (1 cement :3 coarse sand :6 grade stone aggregate 20 mm normal size) over75 mm thik ded dry brick ballast 40mm normal size well rammed and cansoldiated and grouted with fine sand includingnessesary excavation leving and dressing & finishing the top smooth. 32 Providing and laying Doublecharge vitrified floor tiles in different sizes(thickness to be specified by the manufacturer) with water absorptionless than 0.08% and conforming to IS: 15622 / ISO 13006 of approvedmake, in all colours and shades, laid on 20mm thick cement mortar 1:4(1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm . 33 Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.Glazed Vitrified tiles Matt/Antiskid finish of size 600X600 34 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 35 Granite of any colour ,18 mm thick (slab area above 0.50 sqm) 36 Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge. 37 Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete. 38 Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : New work (two or more coats) over and including water thinnable priming coat with cement primer 39 Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm 40 Lettering with black japan paint of approved brand and manufactured 41 Suppling, fitting and fixing good quality, well dressed and well seasoned sal wood work in chaukhat in doors, windows, skylight, fanlights and celetial windows openings, including wedge over clamps all complete including application of two coats of wood preservative of approved quality on the surface butting walls and lintels all complete as per building specification and direction of E/l 42 Supplying, fitting and fixing 35mm thick solid core type decorative double leaf flush door shutter with both sides decorative veneered with black board core bended with high quality phenol formal dehydes synthetic resin of standard make with Aluminium fittings such as hinges, tower bolts, handle, cleats and sand blocks and taxes all complete as per building specification and direction of E/l. 43 Providing and fixing factory made uPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardwares and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately). Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Three track three panels sliding window with fly proof S.Swire mesh (Two nos. glazed & one no. wire mesh panels)made of (big series) frame 116 x 45 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 1.75 sqm). 44 Structural steel work in single section ,fixed with or without connecting plate,including cutting,hoisting,fixing in position and applying a primer coat of approved steel primer all complete 45 Providing two coats of synthetic enamel paint of approved shade and make over steel surface including cleaning the surface thoroughly, scaffolding and taxes all complete as per building specification and direciton of E/l. 46 Carriage Of Materials 47 Bricks=8 km(7+1) 48 Sand=30 km 49 Stone chips =20 km 50 Supplying and fixing C.I. cover without frame for manholes : 560 mm diameter C.I. cover (medium duty) the weight ofthe cover to be not less than 58 kg 51 Making soak pit 2.5 m diameter 3.0 m deep with 45x45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter and 1.20 m long complete as per standard design.with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 52 Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge 150 mm nominal size dia 53 Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. 54 Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. 55 Supplying, filling, spreading & leveling coarse sand of size ange 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer for all leads & lifts, all complete as per direction of Engineer -in- charge. 56 Cost of Drilind 200 mmx165mmx125 mtr.deep bore well in all kind of Soil and rock in rural area for instalation of pump set with Hydrolic DTH Rig machine all complete including all materials, tools,driling rig,air compressureand equipmentsas well as fule, lubricantsand cost of transportation of rig machine annd other vehical up to Site. Basic Rates 57 From 0 - 50 meter 58 From 51 - 125 meter 59 Supply of 200mm dia X 2.00m long UPVC casing pipe conferming to IS : 12818 : 2016 (CML No. 5543459) latest revision including carriage. 60 Supplying all materials, labours, equipments for lowering blue UPVC casing pipes as casing for protecting the sides from falling during the process of drilling all complete including carriage of materials to work site. 61 Supplying all tools, equipments and labour and doing washing, flushing and development of drilled tube well to give clean and clear water all complete as per direction of E/I. 62 Supplying 100mm dis submersible pump sets confirming to 8034 and motor confirming to IS 9283 pump shall be suitable for various delivery head and discharge with stainless steel pump shaft and polypropylene/noryl impeller. Motor suitable for working on 415 + 10, 3HP, 50 Hz, AC supply with cable guard, thurst carbon/fiber bearing to withstand entire hydraulic thurst, water proof winding shall be provided. The pump set shall be suitable for diret coupling Pump shall have suitable outlet as per manufacturers design. Anti thurst stream lined non return valve shall be provided with pump, 3 meter submersible copper conductor cable in single/double run shall be provided with each pump. Submersible pump set 100mm dia (with Polypropylene/ Noryl Impeller) up to 20 stages 2 HP 63 PVC/XLPE insulated PVC sheathed heavy duty, armoured electrical cable with aluminium conductor for working voltage up to and including 1100 volts.(Conforming to IS:1554, part-1)6sq.mm, 2 core. 64 63 amp. Four pole, on load change over switch in sheet enclousre with side handle operation. 65 Medium density polyethylene pipe (MDPE pipe) in standard length with necessary Jointing material like mechanical connector i.e., thread/insert joint / quick release coupler joint / compression fitting joint or flanged joints confirming to ISO: 4427 : 1996MDPE pipe of material grade PE-80 PN16 (dia in mm) 40 mm dia 66 Polythene water storage tank of mark with cover and suitable locking system in double layer confirming to IS: 12701-1996 with latest revision. 67 Providing & fixing brass stop cock of approved quality all complete as per specification and direction of E/I. (A) Brass stop cock 68 (c) 25 mm dia 69 (d) 32 mm dia 70 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes joining of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of E/I. (Approved Brand - ASTRAL/ SUPREME) Concealed work including cutting chases and making good the wall etc.. 71 15mm dia 72 20mm dia 73 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 74 25 mm dia 75 32 mm dia 76 Supplying, fitting and fixing 40 mm high viterous white glazed earthen ware I.W.C. with p trap of Parry Hindustan or any other I.S.S. make including supplying & fixing 15 litres C.I. mosquito proof low down flushing cistern of approved make with complete fittings with C.I. handle and R.S. or bracket with telescopic flush pipe with brass coupling and plumbers joints spindle stop cock of approved quality weight not less than 450 grms. , 15 mm P.V.C. alkathene pipe 45 cm long with brass coupling at both ends and white/ black plastic solid state seal and lead of commander/ cuckoo or other I.S.S. make with hinges or screw etc. painting pipe and cistern etc. with 2 coats of approved paint over a coat of red oxide primer etc. all complete as per specification and direction of E/l. (B) E.W.C. With S trap(b)12.5 lit. low level P.V.C. cistern 77 Supplying, fitting and fixing flat back or angular, lipped front viterous white glazed earthenware urinal of Hindustan Parry or any other approved I.S.S. make with all fittings with C.I. or R.S. brackets, standard size G.I. flush pipe with fitting clamps, 15 mm C.I. body brass spindle stop cock of approved quality weight not less than 400 grms. , 15 mm P.V.C. alkathene pipe 450 mm long with brass coupling at both ends and doing plumber joints including painting of exposed part with 2 coats of approved paint over a priming coat of red oxide, cutting wall and floor, making good the same etc. all complete as per specification and direction of E/l.(A) Flat back or standing corner ( 450 mm x 350 mm ) 78 Supplying, fitting and fixing viterous white glazed earthen ware wash hand basin of Parry or Hindustan or any other I.S.S. approved make supported on pointed c.l. or R.S. brackets 32m C.I. brass waste 15mm dia C.I. body brass spindle stop cock of approved quality of weight not less than 350grms., 32mm P.V.C. waste pipe 750mm long with brass coupling at one end and making plumber joints etc. all complete as per specification and direction of E/l. 79 Providing and fixing lead connection pipe with heavy quality brass coupling 2 Nos. at both ends etc. all complete as per specification and direction of E/l .(ii) 15 mm dia and 45 cm long 80 Providing and fixing N.P/C.P brass/P.V.C porcelain shower rose of 15mm inlet etc. all complete as per specification and direction of E/l (c) 150 mm dia P V C shower 81 Providing and fixing male ended 15 mm dia brass bib cock of approved quality ( wt not less than 350 gms ) with extra socket all complete as per specification and direction of E/l . 82 Providing and fixing 15mm size C.P brass pillar cock (Weight not less than 350 gms) C.I body brass spindle pillar cock of approved quality as per spcification and direction of E/l. (b) C.I. body brass spindle 83 Supplying, fitting and fixing the following items complete with all materials as per specification and direction of E/l. 84 Glass shelf with C.P brass raili)600 x 125 mm glass shelf complete 85 Mirrors of 4 mm thick plate glass bevelled edge mirror including C.P brass revolving fittings, 3 mm plywood board and C P hinges to fix with mirrori) 600x450 mm 86 i) C.P brass towel rail 20 mm x 600 mm with bracket container 87 ii) C.P brass shop dish container medium quality with screw and hinges etc. 88 (iii) C.P brass liquid shop container 89 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 90 (a) 100 mm dia 91 (b) 80 mm dia 92 (c) 50 mm dia 93 Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 fine sand : 3 graded stone aggregate 20mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design:Inside dimensions 600x 850 mm and 45 cm deep for pipe line with three or more inlets :With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 94 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Singlesocketed pipes.110 mm dia 95 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Singlesocketed pipes.75 mm dia 96 Providing & supplying in standard lengths High density polyethylene pipe (HDPE pipe) confirming to IS 4984 / 14151/ 12786 / 13488 (latest revision with necessary jointing material like mechanical connector i.e., thread / insert joint / quick release coupler joint / compression fitting joints or flanged jointsecluding coupler / specials and taxes) grade PE 80-PN10 97 Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 98 75 mm Coupler 99 110 mm Coupler 100 75 mm Single pushfit Coupler 101 110 mm Single pushfit Coupler 102 75 mm Single tee with door 103 110 mm Single tee with door 104 75 mm Single tee without door 105 110 mm Single tee without door 106 75 mm Bend 87.5° 107 110 mm Bend 87.5° 108 75 mm Shoe (Plain) 109 110 mm Shoe (Plain) 110 Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 110 mm 111 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1KV grade of size exceeding 95 sqmm but not exceeding 185 sq mm direct in ground including excavation, sand cushioning, protective covering and refiling the trench etc as required. 112 PVC / XLPE insulated PVC sheathed heavy duty, armoured electrical cable with aluminium conductor for working voltage up to 1100 volts. (Conforms to IS : 1554, part-1) 120 sq mm, 3.5 core 113 Supplying and making cable route marker with cement concrete 1:2:4 (1cement: 2coarse sand : 4graded stone agreegate 20mm nominal size) of size 60 cm X 60 cm at the bottom and 50 cm X 50 cm at the top with a thickness of 10 cm including inscription duly engraved as required. 114 Providing & fixing M.V. danger notice plate of 250 mm X 150 mm, made of mild steel, at least 2mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. 115 Earthing with copper plate 600mmx 600mmx 3mm thick including acessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc.(but without charcoal or cock and salt) complete etc. as required. 116 S/L 8 SWG G.I. wire in ground :- Supplying and laying 8 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including soldering etc. as required. 117 Providing & laying earth connection from earth electrode with 4mm dia copper wire in 15mm dia G.I. pipe from earth electrode, as required. 118 S/F rewireable double pole/TP&N switch disconnector:- Providing and fixing following DP/TP&N sheet metal switch disconnector fuse unit in the existing metal board with rewireable type fuses, including drilling holes in metal board. Making connection etc. as required. 119 16 amps, double pole 120 32 amps, double pole 121 63 amps, double pole 122 32 amps, TP&N 123 63 amps, TP&N 124 Providing and fixing following rating and breaking capacity MCCB with thermomagnetic release and terminal spreaders in existing cubical panel board including drilling holes in cubical panel, making connections etc. as required. 125 25 - 100 amps, 10 KVA fixed thermal setting 126 25 - 100 amps, 16 KVA fixed thermal setting 127 125 amps, 16 KVA fixed thermal setting 128 Providing and fixing following capacity bus bar chamber with 4 strips of length 300 mm made of copper suitable for following capacity complete with all accessories including connections, earthing the body etc. as required 100 amps 129 Providing and fixing following capacity 2pole / 4 pole ON / OFF - load changeover switches with side handle operation, in sheet enclosoure in existing metal board including drilling holes in metal board, making connection, earthing the body etc. as required. 130 32 amps, 2 pole 131 63 amps, 2 pole 132 Providing and fixing following ways surface / recess mounting, vertical type 415 volts, TPN MCB DB of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incommer) as required. 133 4 way ( 8 + 12 ), double door vertical type 134 8 way ( 8 + 24 ), double door vertical type 135 Supplying and fixing 6 amps to 32 amps rating, 240 volts, 10 KA, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCBs DB complete with connections, testing and commissioning etc. as required. 136 6/32 amps, single pole 137 40 amps, single pole 138 Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. 139 Supplying and fixing following rating, four pole ( three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having sensitivity current 30 mili amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 140 16/25 amps 141 40 amps 142 Wiring for light point / fan point / exhaust fan point / call bell point with 1.5 sqmm FR PVC insulated copper conductor single core in surface / recessed PVC conduit, with modular switch, modular plate suitable GI box etc as required. 143 Group A 144 Group B 145 Group C 146 Wiring for twin control points with 1.5 sq mm FR PVC insulated copper conductor single core cable in surface / recessed PVC conduit, 2 way with modular switch, modular plate, suitable GI box etc. as required. 147 Wiring for light/power plug with 2 X 4 sq mm FR PVC insulated copper conductor single core cable in surface / recessed PVC conduit, along with 1 nos 4 sq mm FR PVC insulated copper conductor single for loop earthing etc as required. 148 Wiring for light/power plug with 4 X 4 sq mm FR PVC insulated copper conductor single core cable in surface / recessed PVC conduit, along with 2 nos 4 sq mm FR PVC insulated copper conductor single for loop earthing etc as required. 149 Wiring for Circuit / sub main wiring along with earth wire with following sizes of FR PVC insulated copper conductor single core cable in surface / recessed PVC conduit as required. 150 2 X 1.5 sq mm + 1 X 1.5 sq mm earth wire 151 2 X 2.5 sq mm + 1 X 2.5 sq mm earth wire 152 2 X 4 sq mm + 1 X 4 sq mm earth wire 153 2 X 6 sq mm + 1 X 6 sq mm earth wire 154 2 X 10 sq mm + 1 X 6 sq mm earth wire 155 Supplying and fixing stepped type electronic fan regulator on the existing modulat plate & switch box including connections but excluding modular plate etc. as required. 156 Supplying and fixing modular blanking plate & switch box excluding modular plate etc. as required. 157 Supplying and fixing following size / modules, GI boxes along with modular base & cover plate for modular switches in recess etc as required. 158 1 or 2 Module 159 4 / 5 Module 160 6 Module 161 8 / 9 Module 162 12 Module 163 Supplying and fixing suitable GI box with modular plate and cover in front on surface of in recess, including providing & fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch connection, painting etc. as required (For light plugs to be used in non residential buildings) 164 Supplying and fixing suitable GI box with modular plate and cover in front on surface of in recess, including providing & fixing 6 pin 15/16 amps modular socket outlet and 15/16 amps modular switch connection, painting etc. as required (For light plugs to be used in non residential buildings) 165 Supplying and fixing 2 pin 5 amp. Ceiling rose on the existing junction box / wooen block including connection etc. as required. 166 Supplying and fixing Batten / angle holder including connection etc. as required. 167 Supplying and fixing ding dong sound call bell single phase 230 voltscomplete as required. 168 Supplying, Installation, testing & commisioning of following size ceiling fan 3 blades confirming to IS:374:2019 including the wiring down rods of standard length up to 30 cm with 1.5 sq mm FR PVC insulated copper wire suitable for 230V 50HZ, single phase supply etc. complete as required. 1200 mm (48) 169 Installation of exhaust fan up to 450 mm sweep in the existing opening including making the hole to suit the size of the above fan making good the damage, connection, testing , commissioning etc. as required. 170 15 (450 mm ) metal exhaust fan 171 S.I.T.C. of flowing rating reccess / surface mounted LED round / Square shade down light luminaire with pressure die cast housing for single phase supply voltage. Luminaire shall be confirming to IS: 10322 part-5 / section-2 or IEC:62722 with all neccssary accessories as required. 18/20 W LED Round Down light 172 Approved make wall mounted decorative lamp with nickel / chrome finish with opal glass of lamp type E27 / E22 LED 7/9 W X 2 IS: 10322 part 5 173 S.I.T.C. of flowing rating reccess / surface mounted LED round / Square shade down light luminaire with pressure die cast housing for single phase supply voltage. Luminaire shall be confirming to IS: 10322 part-5 / section-2 or IEC:62722 with all neccssary accessories as required.90/100 W LED flood light 174 2.0 Tr 5 star split AC (inverter type) IS-1391-Part-1 175 Copper tube of size 3/8 for split ac unit1/1.5/2/3 tr capacity including nitride rubber insulation 176 Drain Pipe for AC 177 Outdoor stand for 2.0tr split AC 178 5 KVA online UPS three phase input and three phase output power system of input, voltage range 360V/380v/400v/485v AC, frequency range 40HZ-60HZ +/- 10%, output voltage range 415v +/- 1%, frequency range 50HZ +/- 1% power factor 0.8/3:1, Harmonic distortion- <2% THD(Linear load) : 5% THD (Non- linear Load) 179 MS battery rack suitable for 15-20 UPS battery installation. 180 100Ah tubular lead acid battery with 36 month replacement gurantee, IS:1652:1991 181 Trenching in ordinary soil up to a depth of 60 cm including removal and stacking of serviceable materials and then disposing of surplus soil, by spreading and neatly levelling within a lead of 50 m and making up the trenched area to proper levels by filling with earth or earth mixed with sludge or / and manure before and after flooding trench with water (excluding cost of imported earth, sludge or manure). 182 Supplying and stacking sludge at site including royalty and carriage upto 5 km complete (sludge measured in stacks will be reduced by 8% for payment). 183 Supplying and stacking at site dump manure from approved source, including carriage upto 5 km complete (manure measured in stacks will be reduced by 8% for payment) :2.4.3 Screened through sieve of I.S. designation 4.75 mm 184 Uprooting weeds from the trenched area after 10 to 15 days of its flooding with water including disposal of uprooted vegetation. 185 Spreading of sludge, dump manure and/or good earth in required thickness as per direction of officer-in-charge (cost of sludge, dump manure and/ or good earth to be paid separately). 186 Mixing earth and sludge or manure in the required proportion specified or directed by the Officer-in-charge 187 Preparation of beds for hedging and shrubbery by excavating 60 cm deepand trenching the excavated base to a further depth of 30 cm, refilling theexcavated earth after breaking clods and mixing with sludge or manure inthe ratio of 8:1 (8 parts of stacked volume of earth after reduction by 20% : one part of stacked volume of sludge or manure after reduction by 8%),flooding with water, filling with earth if necessary, watering and finally finedressing, leveling etc. including stacking and disposal of materials declaredunserviceable and surplus earth by spreading and leveling as directed,within a lead of 50 m, lift up to 1.5 m complete (cost of sludge, manure or extra earth to be paid for separately) 188 Providing and displaying of Phoenix palm having ht. 75 cm to 90 cm with 10 to 15 or more leaves, well developed, fresh and healthy in 25 cm size of Earthen pot/Plastic pot & as per direction of the officer-in-charge. 189 Providing and stacking of Polyalthia longifolia (Ashok) of height 180-195 cm. in gunny bag of size 30 cm as per direction of the officer-in-charge. 190 Supply and stacking of plant Bauhinia tomentosa (yellow) of height 60-75 cm. in earthen pots of size 20 cm as per direction of the officer-in-charge 191 Def PRIME SRD+GG CL-C BIS KL 192 LIFEGUARDR(4 KG CLEAN AGENT TYPE FIRE EXTINGUISHER) 193 CP PLUS IP DOME CAMERA 194 CP PLUS IP BULLET CAMERA 195 32 CH NVR 200 MBPS 2 SATA 196 HARD DISK 10TB Enterprises 24*7 Surveillance (WD) PURPLE 197 HARD DISK 4TB Enterprises 24*7 Surveillance (WD) PURPLE 198 CP PLUS POE With Gigabit 199 LG Monitor 18 200 CAT6 CABLE DLINK 305 MTR (23AWG SOLID) (in Bundle) 201 D-LINK 6U RACK 202 D-LINK RJ 45 Connector (in Box) 203 Vault safe locker 204 Add 18 % GST (in Basic Rate must fill 12) 205 Add 1% Labour Cess (in Basic Rate must fill 1)
Contract Date: Jan 06, 2026 Contract Value : 66.01 Lakh
Government Departments No of Bidders 4
47.
Defence #8488668 AOC
Tender For Provn Of 100 Kva Dg Set For Office Complex At Shillong Under Ge Shillong; 1 Excavating in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. or for cable laying or water supply pipes lines etc or not exceeding 10 sqm on plan and not exceeding 1.5 m in depth and getting out in soft/ loose soil complete all as specified and as directed. 2 Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soft/ loose/ hard/ dense soil complete all as specified and as directed. 3 Bringing approved earth (as approved by Garrison Engineer) from sources outside defence land including cost of land, royality if any, transportation, taxes etc for filling including raising earth spreading in layers not exc 30 cm thick in each layer watering,compection with 8 to 12 tone power roller and finished to required size and shape etc any high/depth from existing ground level complete all as specification and as directed. Note :(i). Earth required for the item, shall be supplied by contractor, from out side MOD land at his own arrangment. (ii). All cost of procurment of earth including cost of transportation, royalties, taxes etc. shall be deemed to be included in the unit rate quoted by the contractor.(iii). With referance to clause 3.6 of MES SSR Part-II (2020) on serial page No. 21 it is clarified that measurement of the above item shall be of finished embarkment/treverse of filled earth after consolidation and 10% deduction shall be made from measured and calculated volume to allow for increase in bulk. 4 M & L for precast cement concrete solid block masonry of grade C (5.0) with concrete M 10 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate exceeding 10 cm in width and set in cement mortar (1:6) complete all as specified and as directed. 5 M & L for hardcore (broken stone or boulders) of gauge not exceeding 63 mm, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface complete all as specified and as directed. 6 M & L for cement concrete M10 (Nominal Mix) using 40 mm nominal size graded crushed stone aggregate 75 mm thick in sub base for laying tiles, pavings, etc. complete all as specified and as directed. 7 M & L for cement concrete M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate as in floor 40 mm thick finished even and fair complete all as specified and directed. 8 M & L for cement concrete in foundation, filling and mass concrete in M7.5(Nominal Mix) using 40 mm nominal size graded crushed stone aggregate complete all as specified and as directed. 9 M & L for pre-painted hot-dip aluminium-zinc alloy metallic coated corrugated steel sheet, any pattern corresponding to IS 15965:2012 of durability class 3, atmospheric classification category 3, coating class AZ150, 0.50 mm thick, of an approved colour and having yield strength of 550 MPa as in roof covering/ wall clading fixed with self tapping screws as specified including necessary scaffolding and safety measures at any floor complete all as specified and as directed. 10 S & F for steel work of grade-3 as per IS 10748 in tubular trusses including special shaped washer etc. complete using ERW or HRIW welded tubes conforming to IS 1161: 2014 (Yst 240 Grade) complete all as specified and directed. 11 Preparation of newly or previously untreated steel surface of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and directed. 12 Material and labour for plastering 15 mm thick on fair faces of brick work or concrete surfaces (on vertical surfaces) in cement mortar 1:4 finished even and smooth without using extra cement complete all as specified and as directed. 13 M & L for preparation of newly plastered surfaces of wall and applying two coats of cement base paint over alkali resistant primer complete all as specified and as directed. 14 Supply,install, testing and commissioning of Silent Diesel engine driven generating set 100KVA, 415 Volts 3 phase 4 wire engine as per BS 5514/ IS 10002 and alternator,DG Set as per IS : 13364 complete with relay panel for automatic starting on mains failure, control panel having meters, sound proof canopy etc for capacity 100 KVA as per ISO - 8528 conforming to the detailed specification as under:- 15 (a)Engine : The Diesel Engine shall be radiator water cooled, 126.8 BHP at 1500 RPM , Cylinder 4 Nos. Starting stopping : Electrical start with 12 V DC 1 x 90 AH, 12 V Exide / Prestolite Low Maintenance Battery,Mechanical governer , The fuel tank provided shall be suitably mounted on the base frame fabricated out of 16 SWG MS sheets and capacity to run the genset for 8 to 12 hours continuously on full load.Fuel tank shall have Drain plug, Hand hole for cleaning, vent breather, fuel suction and return connections, fuel level indicator fuel filling neck with cap etc as per the standards.The engine and alteranator shall be directly coupled to ensure perfect alignment.The engine and alternator shall be mounted on a common base frame with AVM pads all as per manufracturers instructions. 16 (b) Alternator : Rating 100 KVA at 1500 RPM 415 V Phase to Phase and 240 Volt Phase to Neutral, 50 Hz 3 Phase 4 wire system alternator Screen protected / drip proof, self ventilating, self excited, self regulated, brushless, contineous duly protention IP 21 as per IS 13364 developing 100 KVA at 0.8 PF.It shall have provision for 10% overload for one hour on every 12 hours, The alternator shall confirm to IS : 13364/BS5000. 17 (c) Controls/Protection : (i) Low LOP fault indication(ii) Indication for Water Temparature, (iii) High Colant Temparature fault Indication, (iv)Failure to start fault indication (v) Battery Volage monitoring, (vi) Low Battery Indication, (vii) Fuel level Indication, (viii) Engine RPM meter, (ix) Engine run hours meter, (x) Voltage for all three Phases, (xi) Amper meter for measuring current in all three phase. (xii) Frequency meter indication, (xiii) Protection for Over/Under Voltage (xiv) Protection for Over/Under Voltage (xv) Electronic tamper proof KWH meter 3 phase, 4 wire system with suitable ratio CTs. (xvi) Oveload protection (xvii)Suitable capacity of Battery charger shall be provided in the control panel to charge the batteries when mains supply in availbale.(xvii) Safeties against low Lube oil Pressure, high coolant Temperature, over load under & over voltage, under & over frequency Auto Shut Down, Visual& Audio Alarm against fault.When the Gen set is running the battery will be charged from the charging alternator. 18 (d)Acoustic enclosure : (i) Shall be maticulously designed CNC Turret punch press and hydraulic press brake manufractured body out of corrossion resistant cold rolled steel 16 SWG CRCA / MS sheet duly surface trated phosphated and finally powder coated constructed from folded sections to ensure regidness and aesthatic in looks.Canopy panel and doors shall have High density/ fire retradent / non igniting and noise reduction type Foam or Resin bonded Rock wool of suitable density properly covered with fibre cloth / tissue and perforated fixed to absorb noise.The average sound levell when measure in greenfiled (ISO 8525 Part 10) at 1 meter distance from all four sides is less than 75 dB (A) average as per CPCB Norms The average stablised hot air temperature rise with i the canopy near suction air filter to bemaintained 7 degree centigrade over and above the ambient temperature Four higned doors shall be provided to canopy one door shall have glass window for control panel.The exhaust gasses shall be taken out through a suitable flexible pipe to prevent any back pressure on the engine.Provision shall be made on the canopy for connectig the output cable terminatiion should be provided. (ii) The exhaustsystem and noise suppressor shall be provided with thermal insulation, to prevent excess heat radiation on the Engine and safe for operator. (iii) Absorbtion type non residential silencer insulated from inside with glass wool shall be provided to suppress exhaust noise from the Engine. (iv) A suitably designed draught ventilation system is to be incorporated. 19 (e)DG power Control Panel shall be outdoor type sheet steel typecubicle type control panel ,floor standing, dust and vermin proof under normal conditions complete with all internal wiring & will house the following:- (i) AC voltmeter (ii) AC ammeter (iii) vibrating reed Frequency meter (iv) Indicating Lamps for SET ON & LOAD ON (v) MCCB for short circuit & Overload Protection (vi) Aluminium Bus bars of adequate rating (vii) Provision for bottom entry & Exit of power cabling (viii)set of current transformer (ix) set of control fuses. 20 NOTE:(a) DHPP for testing purpose shall be supplied by the contractor without any extra cost to Department (b) The contractor shall arrange for artificial load (water load/Electrical load) for testing for final testing of DG Set at Site and the cost is deemed to be including in above offer. (c) All expences for Testing of DG Set be included. (d) One set of latest Spare part catalogue with price, exploded view of parts and users manual are deemed to be included in the offer. (e) All civil work including foundation for DG set as per manufacturers drawing/specification, foundation for AMF panel. (f) The rate quoted is deemed to be included for initial filling of radiator colant and lubricating oil upto level. 21 Testing : (i) All routine test certificates from the manufacturer in respect of the diesel engine, alternator and the control panel will be made available by the contractor. (ii) The Generating set shall be run for a period of 12 hours, of which at least 6 hours shall be at the rated load and for a period of one hour at 10% over load in above 12 hours running. (iii) All instruments, equipments, materials including DHPP and Engine oil and labour required for testing will be made available by contractor at his own cost and unit rate in Sch A will be deemed to be included for testing to the entire satisfaction of Engr-in-Charge :- (a) Insulation resistance test on the alternator and control panel. (b) High voltage test as per BS-2613 clause 33 on the alternator when still hot. (c) Efficiency test at rated load and over load.(d) All test as described above under testing clause shall be carried out in presence of officer nominated by accepting officer. 22 Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated cable for working voltages of 1100 V, PVC sheathed, armoured, 3.5 core, nominal cross sectional area of main conductor 95 sqmm, stranded aluminium conductor, ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc. complete all as specified and as directed. 23 M & L in repair for earthing complete with galvanised steel plate earth electrode 600 mm X 600 mm X 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to earthing lead of 32 mm X 6 mm galvanised mild steel strip by means of bolts, nuts, check nuts and washers of galvanised iron from earth plate to test point upto 7.5 metre including all as shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete chamber in cement concrete M15 (Nominal Mix) using 20 mm nominal size coarse aggregate, precast RCC cover slab in cement concrete M15 (Nominal mix) using 20 mm nominal size coarse aggregate of size 40 cm X 40 cm X 5 cm reinforced with 8 mm dia TMT bars @ 150 mm c/c with one handle for lifting made out of 8 mm dia bar, GI funnel, GI wire mesh filter, 20 mm dia GI pipe medium grade for watering, 40 mm dia GI pipe medium grade for protection of earthing lead, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil/ strata and testing complete all as specified and as directed.
Contract Date: Dec 23, 2025 Contract Value : 16.68 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 3
48.
Educational and Research Institute #8444551 AOC
Supply of All Lab Equipment Supply, Installation And Commissioning Of All (Botany, Chemistry, Physics, Geology, Zoology And Geography) Lab Equipments On Turn Key Basis At Item Wise For Govt. Model College, Jhabua - 457661 (Nmdc). , Chemistry Lab Equipment , Analytical/ Chemical Weight Box , Chemical Balance , Chromatography Cabinet , Digital Conductivity Meter , Digital Potentiometer , Distillation Apparatus , Electronic Balance , Kipp?S Apparatus ? Plastic , Magnetic Stirrer With Hot Plate , Melting Point Apparatus ? Electrical , Vortex Shaker , Water & Soil Analysis Kit ? 8 Parameters , Water Bath - 06 Holes , Thin Layer Chromatography (Tlc) Kit , Uv-Visible Spectrophotometer , Digital Ph Meter ? Table Model , Rubber Corks No.1,2,3,4,5,6,7, 8,9,10,11 , Ashless White Filter Paper (125Mm) Circles , Desecators, With Cover And Procelain Plate, Plastic Knob_(Borosil_100 Mm) , Low Form Silica Crucible Without Lid_(Infusil_25 Ml) , Crucible, Gooch Type, Low Form, With Sintered Dise, G3_(Borosil_50 Ml) , Crucible, Gooch Type, Low Form, With Sintered Dise, G4_(Borosil_50 Ml) , Bottle Key For Opening And Closing Bottles With S 40 And S 28 Screw Caps_(5 Units) , Volumetric Flasks , Volumetric, With Interchangeable Solid Glass Stopper Accuracy As Per Class B_(Borosil_50 Ml) , Volumetric Flasks , Volumetric, With Interchangeable Solid Glass Stopper Accuracy As Per Class B_(Borosil_100 Ml) , Volumetric Flasks , Volumetric, With Interchangeable Solid Glass Stopper Accuracy As Per Class B_(Borosil_250 Ml) , Flasks, Erlenmeyer, Conical, Narrow Mouth_(Borosil_500 Ml) , Flasks, Erlenmeyer, Conical, Narrow Mouth_(Borosil_100 Ml) , Flasks, Erlenmeyer, Conical, Narrow Mouth_(Borosil_250 Ml) , Beakers, Low Form Beakers With Spout_(Borosil_50 Ml) , Beakers, Low Form Beakers With Spout_(Borosil_100 Ml) , Beakers, Low Form Beakers With Spout_(Borosil_250 Ml) , Beakers, Low Form Beakers With Spout_(Borosil_400 Ml) , Beakers, Low Form Beakers With Spout_(Borosil_500 Ml) , Burettes Boroflo , Fitted Withboroflo Gp (General Purpose), Screw Thread With Ptfe Keys, Accuracy As Per Class B_(Borosil_50 Ml) , Pipettes , Trnsfer Volumetric , Class B_(Borosil_10 Ml) , Pipettes , Trnsfer Volumetric , Class B_(Borosil_25 Ml) , Watch Glassess - Line_(Borosil_10 Ml) , Glass Rod 8_(General_Each) , S.S. Spatula 6_(General_Each) , Ss Tong - 12_(General_Each) , Wash Bottles , Set With Interchangeable Stopper_(Borosil_500 Ml) , Funnels Plain, 600 Angle, Short Stem_(Borosil_100 Ml) , Porcelain Dish 4_(General_Each) , Buckner Funnel 3 -75 Mm_(General_Each) , Tubes, Centrifuge, Conical Botton, Graduated, With Stopper_(Borosil_15 Ml) , Cylinders Graduated, Single Metric Scale, With Pour Out, Withhexagonal Base, Class B_(Borosil_10 Ml) , Cylinders Graduated, Single Metric Scale, With Pour Out, Withhexagonal Base, Class B_(Borosil_25 Ml) , Cylinders Graduated, Single Metric Scale, With Pour Out, Withhexagonal Base, Class B_(Borosil_100 Ml) , Flasks, Boiling, Roundbottom, Short Neck, Withinterchangeable Joint_(Borosil_1000 Ml) , Flasks, Boiling, Roundbottom, Short Neck, Withinterchangeable Joint_(Borosil_100 Ml) , Flasks, Boiling, Roundbottom, Short Neck, Withinterchangeable Joint_(Borosil_500 Ml) , Funnels Separating, Pear Shape, With Glass Stopcock And Interchangeable Stopper_(Borosil_125 Ml) , Funnels Separating, Pear Shape, With Glass Stopcock And Interchangeable Stopper_(Borosil_250 Ml) , Funnels Plain, 60° Angle, Short Stem_(Borosil_25 Ml) , Funnel (Plasic) , Tubes, Test, With Rim_(Borosil_70 Ml) , Relative Density Bottles With Capillary Bore Interchangeable Teflon Stopper_(Borosil_10 Ml) , Condensers , Liebig, With Sealed Inner Tube_(Borosil_200 Mm) , Reagent Bottles Graduated With Screw Cap And Pouring Ring_(Borosil_250 Ml) , Chromatography Jar (Rectangular Glass Jar) , Burete Stand With Road, Clamp And Boss Head , Capillary Tube , China Dish , Chromatography Paper , Filter Paper , Ignition Tube , Glass Bod Bottle (250Ml) , Sprit Lamp (Made Of Alluminium) , Stelegmometer (Borosilicate Glass) , Viscometer (Borosilicate Glass) , Test Tube Holder (Multicolour Wooden And Iron) , Test Tube Stand (Plastic, 6*6*7Cm) , Test Tube Cleaner Brush , Copper Water Bath With Bakelite Handle Heatting Countenor And Concentric Ring , Metal Tripode Stand (10*10*12) , Geography Lab Equipment , Latest Indian State Maps Of India (Laminated) Certified By S.O.I.Size 70X100cms. , State Maps Of Physical Series. , Map On Worlds & Continents Size 100X140cms. (Laminated). , Geographical Wall Maps :English / Hindi Size 70 X 100 Cms. (Laminated). , 1). 1Physical Feature , 2). Political , 3). Natural Vegetation , 4). Natural Region , 5). Agriculture , 6). Rock & Minerals , 7). Irrigation & Power Projects , 8). Industries , 9). Soils , 10). Railways , 11). Roads , 3- D Map Of India Political. , 3- D Map Of Worldpolitical / Physical , India Political Cum Road Guide Map Size 145X100cms. , India Physical Mapsize 145X100cms. , 3 D State Map Of M.P. , Maps Of India-World & Continents Giant Size , Weather Map Of India (Set Of 14 Maps) , Daily Weather Report Set Of 12 (Photocopy). , Topographical Sheet , Political Globes 40Cm Dia. , Measuring Chain , Measuring Tape : Size 30Meter Made Of Fibre Glass (Freemans Make) , Ranging Rod: , Abney Level: , Thermometers: , Min. & Max. Bulb Thermometer C&F Combined: Zeal Uk Made. , Dry & Wet Bulb Thermometer C&F Combined: Zeal Uk Made. , Wall Thermometer (Imported): , Box Sextant : , Clinometer Tangentindianpattern : Made Of Full Brass (Survey Of India Pattern) , Aerial Photographs , Aerial Photographs Coloured. , Portable Weather/Meteorological Station (Imported) : , Self Recording Rain Gauge: , Wind Vane: , Robinson’S Cup Anemometer : , Latest Tracing Table For Geography Lab Size 36”*48” , Oxford Student Atlas For India , Oxford Student Atlas (Hindi) For Competitive Exams: Bharat Sanskaran , National Geographic Atlas Of The World, 11Th Edition , India Road Atlas: India Tourist Map Hindi , Geology Lab Equipment , Polarising (Petrological Microscope: (Export- Quality) , Ore Minerals And Rocks Samples , Hand Lens 10X , Geological Map Of India , 3 D Geological Map Of India , Tectonic Map Of India , Geotechnical Map Of India , Geomorphological Map Of India , Tectonic Map Of India & Adjoining Countries , India Rock & Mineral Map , India Rock Type Map , India Ocean Geology Map , India Soil Texture Map , India Earthquake Map , India Soil Cover Map , India Physiography , India Relative Relief Map , India Slope Map , India River Basin Map , India Drainage Map , India Soil Map , India Land Use Map , India Coastal Features Map , India Water Pollution Map , India Air Pollution Map , Model Showing Dip. Strike & Escarpment In Inclined Strata , Model Showing True & Apparent Dip In Inclined Strata , Model Showing Strike & Dip In Inclined Strata , Model Showing Strike & Pitch (Plunge) In Folded Strata , Symmetrical Anticline/ Syncline , Asymmetrical Anticline/ Syncline , Pitching Anticline/ Syncline , Monoclinal Fold , Isoclinals Anticline/ Syncline , Recumbent Fold , Fan Fold , Dome Fold , Strike Faults In Inclined Beds , Dip Faults In Inclined Strata , Faults Across A Syncline Or Anticline , Faults Across A Pitching Anticline Or Syncline , Dipfaults In Folded Strata Across A Syncline Or Anticline , Dipfaults In Folded Strata Across A Pinching Syncline Or Anticline , Rockscycle Model , Ocean Feature Model , Hydrological Cycle Model , Earth History Models , Land Form Model , Comparative Terrain Modrel , Models Of Volcanoes , Models Of Volcanoes , Model Of Contour Map Interpretation , Model Of Plate Structure & Surface Morphology , Models Of Fold Structure & Its Geomorphic Evolution , Model Of Crustal Movement , Model Of Island Formation , Model Of Bottom Configuration , Model Of Depositional Formation , Fold Structure & Its Geomorphic Evolution Models , Model Of Change On Earth’S Crust , Geological Hammer , Haversacks , Toposheets : Published By Survey Of India Scale 1;50000. , Thin Section Slides Of Rocks & Minerals , Rocks Set , Rocks (15 Igneous+15 Sedimentary+15 Metamorphic Rocks) , Rocks (Igneous) Set Of 15. , Rocks (Sedimentary) Set Of 15. , Rocks (Metamorphic) Set Of 15. , Rocks Forming Minerals Set Of 10. , Physics Lab Equipment , Battery Charger 2 V To 12 V , Ballistic Galvanometer (100 Ohms) With Lamp & Scale Arrangement , Crown Glass Prism , Spectrometer 6 , Moment Of Inertia Table , Complete Apparatus To Verify Law Of Parallel & Parpendicular Axis For Moment Of Inertia , Study Of Compound Pendulum , Reading Telescope , Study Of Bending Of A Beam , Young’S Modulus Using Cantilever , Surface Tension By Jaeger’S Method , Viscosity By Poiseuile’S Method , Measurement Of Low Resistance By Carry Foster Bridge , Potentiometer , Newton’S Law Of Cooling Apparatus , Sodium Vapor Lamp 35 Watt , Transformer For Sodium Lamp , Mercury Lamp , Transformer For Mercry Lamp , Fresnel’S Biprism , Bi-Prism Assembly Without Optical Bench , Half-Shade Polarimeter , Electroscope – Gold Leaf , Af Generator 200 Khz , Vibration Magnetometer , Tangent Galvanometer , E/M By Thompsons Method , Study Of Absorption Spectra Of Iodine Vapor – Complete Setup , Hysteresis (B-H) Curve Of Ferromagnetic Material With The Help Of Cro , Study Of A Voltage Regulation System (Half Wave, Full Wave & Bridge Rectifier) , Transistor Characteristics , Tunnel Diode Characteristics , Specific Resistance Energy Gap Of A Semiconductor , Regulated Power Supply Using Transistor , Study Of Two Stage Rc Coupled Amplifiers , Diode & Zener Diode Characteristics Apparatus , Charging & Discharging Of Condenser , To Find The Wavelength Of Sodium Light With The Help Of Fresnel’S Bi-Prism , Study Of Lissasjous Figure , Barton Apperatus , Adjustable Height Stand , Capillary Tube Packet Of Different Radius , Platinum Resistance Thermometer , Desoldering Tool , Thermocouple Apperatus , Jeft Aapperatus To Study Cherecterstic Curve , Plane Transmition Gating , Holografic Differention Gating , Physical Balance , Weight Box , Vernier Calipers , Screw Gauge - 20 X 1 Mm , Stop Clock – L.C. 1 Sec , Digital Stop Watch , Resistance Box , Ammeter Dc , Ammeter Ac , Voltmeter Dc , Voltmeter Ac , Analogmultimeter , Digitalmultimeter , Soldering Iron , Travelling Microscope , Diode Lazor , Holographic Differection Gating , Logic Gate Apperatus Standard Tool Box , Connecting Lead Wire For Multimeter , Fly Wheel , Mirror Strip With Holder , Digital Thermameterstandard , Mercury Thermameter Standard , Digital Voltmeter , Digital Amoeremeter , Digital Multimeter With Cords , Aluminium Tray 6 Inch * 1 Ft , Uv Lamp 30 Watts , Zoology Lab Equipment , Volvox , Grasshopper Testis Fixed For Meiosis , Ascaris (Male And Female) , Taenia Solium (Tap Worm) , Nereis And Heteronereis , Leech (Hirudinaria) , Earthworm , Squilla , Termite Queen , Stick Insect , Praying Mantis , Unio , Pila , Loligo , Balanoglossus , Herdmania , Honey Bee Life Cycle , Lac Insect Life Cycle , Silk Moth Life Cycle , Myxine Glutinosa-Excellent Specimen , Petromyzon (Lampray) , Salpa , Zygaena (Hammer Headd) , Torpedo (Electric Ray) , Exocoetes (Flying Fish) , Echineis (Sucker Fish) , Frog , Rhacophorus , Hyla , Salamender , Uromastix , Draco , Chamaeleon , Viper Russeli , Naja , Python , Hydrophis , Bat , Fossil Specimens: Fossil Cast Of Archeopteryx Lithographica From U.K. (Cast From Original) Full Size , Amoeba W.M , Earthworm- Septal Nephridia , Mouth Parts - Anapheles Male , Mouth Parts - Anapheles Female , Chick Embryology - 13 Hrs Stage (W.M.) , Chick Embryology - 16 Hrs Stage (W.M.) , Chick Embryology - 24 Hrs Stage (W.M.) , Chick Embryology - 33 Hrs Stage (W.M.) , Chick Embryology -72 Hrs. Stage (W.M.) , Chick Embryology -96 Hrs. Stage (W.M.) , Balanoglossus - T.S. Through Pharyngeal Or Branchio-Genital Region Of Body , Balanoglossus - T.S. Collar Region , Amphioxus - T.S. Passing Through Oral Hood , Amphibia - Blastula V.S./W.M. , Amphibia - Gastrula V.S./W.M , Rhomboid Scale W.M , Lampbrush Chromosome , Mitosis Cell Division: Prophase , Mitosis Cell Division: Metaphase , Mitosis Cell Division: Anaphase , Mitosis Cell Division: Telophase , Meosis Cell Division: Leptotene Stage , Meosis Cell Division: Zygotene Stage , Meosis Cell Division: Diplotene Stage , Meosis Cell Division: Pachytene Stage , Meosis Cell Division:Diakinesis Stage , Meosis Cell Division: Metaphase I , Meosis Cell Division: Anaphase-Telophase I , Meosis Cell Division: Metaphase Ii , Meosis Cell Division: Second Anaphase Telophase , Rabbit (Mammals) - Pitutary Gland (T.S.) , Rabbit (Mammals) - Adrenal Gland (T.S.) , Rabbit (Mammals) - Kidney (L.S.) , Striated Muscles , Non-Striated Muscles , Cardiac Muscles , Planaria W.M , Waucheria Brancofti (Filaria) Smear , Trichinella Spiralis Cyst In Muscle , Tape Worm Scolex W.M. , Uv-Visible Spectrophotometer , Rocking Microtome , L Mould For Casting Paraffin Block , L Mould For Casting Paraffin Block , Chromatography Cabinet , Paper Chromatography Kit , Haemocytometer Kit , Haemoglobinometer (Sahlis) Kit , Bp Apparatus , Stethoscope Standard , Micropipette Fully Autoclavable Volume 0.02 - 2 Ul , Micropipette Fully Autoclavable Volume 0.5 - 10 Ul , Micropipette Fully Autoclavable Volume 20 - 200 Ul , Micropipette Fully Autoclavable Volume 100 - 1000 Ul , Whatmann Filter Paper No. 1 , Secchi Disc , Gel Electrophoresis Kit (Vertical) , Electrophoresis Apparatus (Paper Model) , Insect Collecting Net Portable , Entomological Pins , Insect Killing Jar , Insect Spreading Board (Adjustable) , Pointer Eye Piece Imported 5X , Pointer Eye Piece Imported 10X , Pointer Eye Piece Imported 15X , Dissection Of Dog Fish (Scoliodon) , Prawn Dissection , Comparative Model Set Of Vertebrates Hearts -Set Of 5 , Evolution Of Man - Set Of 4 Models , Life History Of Frog , Earthworm Dissection , Earthworm Cierculatory System , Frog Dissection , Dna Model Set Of 4 On Board , Human Endocrine Glands , L.S. Of Kidney Of Human On Board , Articulated Skeleton Of Fowl In Showcase , Articulated Skeleton Of Shark (Dog Fish) In Showcase , Pectoral Girdle - Frog , Pectoral Girdle - Lizard , Pectoral Girdle - Pigeon , Pectoral Girdle - Lepus , Pelvic Girdle - Frog , Pelvic Girdle - Lizard , Pelvic Girdle - Pigeon , Pelvic Girdle - Lepus , Limb Bone - Fore Limb -Frog , Limb Bone - Fore Limb -Lizard , Limb Bone - Fore Limb -Pigeon , Limb Bone - Fore Limb -Lepus , Limb Bone - Hind Limb -Frog , Limb Bone - Hind Limb -Lizard , Limb Bone - Hind Limb -Pigeon , Limb Bone - Hind Limb -Lepus , Botany Lab Equipment , Nested Square , Circular Quadrats , Herbarium Press , Herbarium Paper Sheet , Drawing Board , Field Collection , Prismatic Binocular , Plastic Collection Bottles 60Ml , Plastic Collection Bottles 125Ml , Plastic Collection Bottles 250Ml , Mycoplasma , Nostoc Wm , Oscillatoria Wm , Polytrichum Ls , T.S. Of Aerial Shoot , T.S. Of Young Stem , T.S Of Old Stem , T.S.Of Microsporophyll , L.S Of Ovule , L.S Of Male Cone , Pollen Grains , L.S Of Female Cone , L.S Of Ovule , L.S Of An Ovule , L.S Of Mature Seed , Longitudinal Section Of Root Apex , Tyloses , Longitudinal Section Of Shoot Apex , Transverse Section , Growth Rings,Heartwood , Lenticel , Longitudinal Section Of Ovule , L.S Of Ovule Showing , Transverse Section Of Mature , V.S Of Leaf , T.S Ofstem , Free Central , Superficial Placentation , Ceratophyllum T.S Of Stem , Ceratophyllum V.S Of Leaf , Trapa V.S Of Leaf , Eichhornia V.S Of Leaf , Marginal Placentation , Amophilla V.S Of Leaf , Axile Placentation , Volvox Vegetative , Oedogonium Vegetative , Oedogonium Macrandrous , Oedogonium Nannandrous , Chara Vegetative , Chara Reproductive , Vaucheria Vegetative , Vaucheria Reproductive , Ectocarpus Vegetative , Ectocarpus Reproductive , Polysiphonia Vegetative , Polysiphonia Reproductive , Albugo Sexual , Albugo Hypertrophy , Mucor Sporangial , Mucor Zygosporic , Yeast Budding , Peziza , Puccinia Uredo , Puccinia Teleuto , Puccinia Aecidial , Puccinia Pycnidial , Alterneria , Lichen , Riccia Vegetative , Riccia Antheridia , Riccia Archegonia , Riccia Sporophyte , Marchantia Thallus , Marchantia With Gemma , Marchantia Antheridial , Marchantia Archeogonial Plant , Anthoceros Vegetative , Anthoceros Antheridia , Anthoceros Archegonia , Anthoceros Sporophyte , Polytrichum Vegetative Plant , Polytrichum Antheridia , Polytrichum Archegonium , Polytrichum Rhizome , Funaria Vegetative , Funaria Anthridia , Funaria Archegonium , Pteris Vegetative , Pteris Anatomy , Psilotum Anatomy , Psilotum Anthridia , Psilotum Archegonium , Lycopodium Stem , Lycopodium Stem , Lycopodium Root , Lycopodium Cone , Selaginella Vegetative , Selaginella Stem , Selaginella Rhizophore , Selaginella Strobillus , Equisetum Stem , Equisetum Cone , Equisetum Rhizome , Marsilea Petiole , Marsilea Sporocarp , Marsilea Rhizome , Cycas Ordinary Root , Cycas Coralloid Root , Cycas Leaflets , Cycas Rachis , Cycas Ovules , Pinus Rootyoung , Pinus Stem Young , Pinus Dwarf Shoot , Pinus Needle , Pinus Male Cone , Pinus Female Cone , Ephedra Root , Ephedra Stem Young , Ephedra Leaf , Maize Root , Gram Root , Beet Root , Maize Stem , Dracaena Stem , Sunflower Stem , Bignonia Stem , Nyctanthes Stem , Boerhaavia Stem , Leptadenia , Salvadora , Achyranthes , Maize Leaf , Mango Leaf , Apparatus For Demonstrating Osmotic , Ganongs Demonstration , Endoosmometer , Apparatus For Experiments , Blackmans App , Apparatus To Show The Stomata , Apparatus To Measure The Loss , Potometer For Observing , Ganongs Potometer On Stand , Farmers Potometer , Apparatus To Show The Unequal , Leaf Clasp Ganongs Special Pattern , Leaf Clasp Ganongs Simple From , Transpiration Tube , Molls App. , Molls Half Leaf Experiment , Ganongs Light Screen-Strongly , Wilmots Bubbler , Respiration App. , Ganongs Respirometer , Apparatus To Demonstrate The Phenomenon , Apparatus To Show The Absorption Of Oxygen , Parometer For Measuring-The Degree , Apparatus To Show The Unequal , Leaf Clasp Ganongs Special Pattern , Leaf Clasp Ganongs Simple From , George John Mendel , Charles Robert Darwin , Louis Pasteur , Anton Van Leeuwenhoeck , Sir J C Bose , Birbal Sahni , Sunder Lal Hora , Dr H G Khorana , Sir Alexander Flemming , Plant Cell Mitosis , Plant Cell Meiosis , T.S. Stem- Monocot , Diocot Sunfloer , Monocot , Dicot , Monocot , Dicot , Root Systems , Root Modifications , Stem Modifications , Strucuture Of Flower , Calyx And Corolla , Inflorescences , Taxonomy Of Cruciferae- Brassica , Taxonomy Of Malvaceae-Hibiscus Rosa , Citrus , Lathyrus , Rosa Indica , Solanum , Allium Cepa , Zea Mays , Helianthus , Nerium Indicum , Calotropis , Ocimum Sanctum , Dhatura , Triticum Aestivum , Coriandrum , Mitochondria , Chloroplast , Nucleus , Chromosome , Dna , Protein Syntheis , Monohybrid Crossing Complete , Monohybrid Crossing In Complete , Dihybrid Crossing , Mendelian Explanation Of The , Plant Respiration , Plant Transpiration , Plant Osmosis And Root Pressure , Photosynthesis Light Reaction , Photosynthesis Dark Reaction , Glycolysis , Krebs Cycle , Marchantia Structure And Life History , Moss Life Histroy , Fern Strucuture And Life History , Cycas Life History , Ephedra Structure And Life History , Gnetum Structure And Life History , Pinus Structure And Life History , Plant Cell Ultra Strucuture , Plant Kingdom Showing Flowering And Non- Flowering Plants , Comparison Of Dicot And Monocot Plants , Fossil Plants , Classification Of Fruits , Fertilization Showing Germination Of Pollen Grain , T.S. Anther And Its Development , Megasporogenesis , Germination Of Pollen Grain And Development Of Male Gametophyte , Development Of Embryo And Endosperms , Microsporangium , Types Of Embryo Sac , Forms Of Androecium , Forms Of Gynoecium , Development Of Monocot Embryo , Placentation , Pollination Different Types , Forms Of Ovule , Forms Of Calyx And Corolla , Plant Anatomy Showing Simple Tissues, Parenchyma, Collenchyma And Sclerenchyma , Plant Anatomy Showing Complex Tissues Xylem , Plant Anatomy Showing Complex Tissues Phloem , Tobacco Mosaic Disease , White Rust Of Crucifers , Lichens , Selaginella , Lycopodium , Marsilea , Cycas: Foliage Leaf , Cycas: Corolloid Root , Cycas Male Cone , Cycas: Microsporophyll , Cycas: Megasporophyll , Pinus: Stem , Pinus: Male Cone , Pinus: Female Cone , Ephedra: Male Strobilus , Ephedra: Female Strobilus , Hydrilla , Potamogeton , Ceratophyllum , Trapa , Eichhornia , Nymphaea , Opuntia , Ruscus , Asparagus , Australian Acacia , Pneumatophore Or Respiratory Roots , Viviparous Germination , Inflorescence Of Euphorbia , Inflorescence Of Triticum Aestivum , Inflorescence Of Brassica Campestris , Inflorescence Of Achyranthus Aspera , Marsilea , Cycas: Foliage Leaf , Cycas: Corolloid Root , Cycas Male Cone , Cycas: Microsporophyll , Monocular Biological Microscope , Digital Ph Meter , Heating Mantle Coil Shape , Digital Colony Counter , Rotary Microtome , Microwave Oven , Digital Balance , Heating Mantle , Hot Air Oven , Incubator , Ph Indicator Paper Strips, Ph Range: 1-14(Pack Of 10) , Ph Indicator Paper Strips,( Pack Of 10) , Refrigerator Normal (500 Ltr)
Contract Date: Nov 27, 2025 Contract Value : 49.97 Lakh
Local Bodies No of Bidders 4
Madhya Pradesh View Result →
49.
Agriculture #8370827 AOC
E-Tender (2Nd Call) For Procurement Of Laboratory Instruments, Equipment, Appliances For The College Of Veterinary Sciences And Ah, Rk Nagar Under The Nec Funded Project For The Year 2025-2026 , Biosafety Cabinetclassii, A 2 With Accessories And Power Back Up (Bacteriology)--• The Biological Safety Cabinet Should Be Of Class Ii, Type A2 Designed In Compliance With International Standards • The Biological Safety Cabinet Quoted Instrument Model Must Have International Standards Test Likensf, Tuv Nord, En 12469 Certification. Certificate Copy Must Be Provided Along With The Technical Bid. • Working Area Should Be Around 4Foot. It Should Have Exterior Dimension W X H X D Of 1300X 1568 X 800 And Interior Dimension Wxhxdof 1200X 780X 630 • It Should Have 1 Piece Grade 304 Stainless Steel Or Thermos Scientific Smart Coat Interior • Itshouldhavefeatureforpersonalprotection,Sample Protection, Cross Contamination Protection And Environmental Protection. • It Must Utilize Brushless Dc Motor Technology Which Uses Significantly Less Energy With Less Heat Emission Provision Compared To Traditional Ac Motor Technology To Ensure Lower Levels Of Energy Consumption. • It Should Have 10° Sloped Front For Exceptional Comfort And Ergonomics • Thesystemshouldbedesignedwithdualmotor. • The Motor Must Automatically Adjust Or Control Fan Speed In Real Time To Maintain Constant Airflow During Filter Loading Or Temporary Obstruction. • Air Flow Direction: Vertical Laminar Flow & Air Intake Across Front Opening And 70% Recirculation. • Filter: High Performance Particle Air Filter H14(Hepa En1822), Filtering Efficiency 99.995% Mpps Or Better. • Energy Saving Mode When Cabinet Not In Use With Maintaining Sterility. Continuous Airflow Helps To Maintaina Sterile Environment, Evenwhen The Cabinet Is Not In Use. • Thesystemshouldhaveindependentsensorstodetect Pressure Changes Across The Exhaust And Down Flow Plenum/ Air Velocity And Should Indicate Alarm Signal When A 20-30% Change In Inflow/ Exhaust Or Down Flow Occurs. • Control Panel And Performance Monitor Displays Inflow/ Down Flow Velocities, Hours Of Use Etc. To Verify Proper Cabinet Operation. • Frontglasswindowshouldbeeasilyloweredforthorough Smart Cleaning Of Inner Surfaces And Designed To Protect Users By Maintaining Inflow, Even When The Window Is Lowered. • The Uv Light Must Be Quoted Which Should Be Programmable From 30 Min To 24 Hrs. In Minimum 30 Minutes Increment To Shut Off Automatically. The Settings Must Allow The User To Program The Timer. • The Cabinet Noise Level Must Be Less Than 63 Db(A) As Measured In A Sound Proof Room To • Promote More Comfortable And Safer Working Habitsof The User A Per Nsf/ Ansi 49. • The Controller Must Be Located On A Slanted Frontpanel So It Is Easy To See From A Seated Working Position In Front Of The Cabinet. • Control Panel Should Be A Large Digital Color Touch Screen Display With Health Monitoring System, Valuable Safety And Performance Data With Constant Read-Out Of Downflow/ Inflow Velocities And Hours Of Operation In Real-Time, Number Of Hours Of Use On The Hepa Filters. • The Front Window Sash Must Be Angled 10° Sloped Front For Operator Comfort. • Two Pieces Of Removable And Autoclavable Stainless Steel Arm Rest Should Be Provided For Operator’S Comfort Without Disturbing The Air Flow. • The System Must Have Audio Visual Alarms To Indicate When Inflow Is Restricted And As Well As Whether Front Window Is In Correct Position Or Not. • Theworkareashouldbeilluminatedwithswitchable Fluorescent Lamp Of Lighting Power >120 Fc Or Higher. • Suitable Height Floor Stand Without Casters Should Be Provided. • In Built Access Ports, 2 Nos. (1 On Each Side) Shouldbe Available. • It Has Single Piece Stainless Steel Work Tray For Easy Cleaning And Decontamination. • Warranty:Minimum3year. • Electrical Supply Available: 230V A.C, Single Phase, 50 Hz. • Bidder Should Provide Printed Brochure Of The Quoted Model And Details Specification Should Be Available In The Manufacture Website. • Customized Model Would Not Be Accepted Withoutany Quality Control Certificate Or 3Rd Party Approved Certification • Prompt & Efficient After Sales Service Should Be Available In The Eastern Region Of India. • User List: Minimum 10 Numbers Of Quoted Model Should Have Been Installed In Government • Institution(Listshouldbeenclosed). • Quotedwith2kvaservovoltagestabilizer. • Three(2)Yearswarranty. • 3Kva Stabilizer , Autoclave--• Capacity: 60L To 80 L, Vertical, Watt:3-4Kw, Operation Mode: Fully Automatic (Digital Controller With Automatic Pressure Release Valve), Construction: Double Walled Inner Chamberstainless Steel 304, External Chamber: Stainless Steel 304 Lid Stainless Steel 304, • Ring & Stand: Stainless Steel 304 Heater Immersion Heater, Gasket: High Temperature Silicone Rubber Gasket (Joint Less), Locking System Radial Locking Mechanism W/ Pedal Lifting Device/ Butterfly Nut Lid Lock. • Temperature Range: 121°C To 125°C Temperature Accuracy ±1°C • Temperaturesensor:Pt100 • Controller: • Digitaltemperaturecontroller • In-Builtdigitaltimer0-60Minutes • Endofsterilizationbuzzeralert • Digitaldisplayofpressure • Sensorbrokenindication • Pressure:15To20psior Above. • Steam Release: Automatic Steam Release After Sterilization • Releasevalve:Solenoidvalve • Pressuredisplay:Dialtypepressuregauge • Safety • Overpressuresafety Valve • Automaticvacuumbreaker • Lowwaterlevelcut-Off Sensor • Basket:Wiremeshbasket • Powersupply:220Volts50hz • Waterinletvalve • Directlypourintothe Chamber • Standardaccessories: • Waterlevelindicator(Glass) • Waterdrainvalve • Warranty:3Years(On-Site) , Bod Incubator-- • Capacity:200L • Temperaturerange:Ambient+5°Cto+60°C • Chamber:Stainlesssteel • Temperatureaccuracy:±0.5°C • No.Ofshelves:3-6 • Temperaturesensor:Pt-100 • Shelves:Perforatedstainlesssteel • Dimension:Lxwxh(Cm)-80X80x180 • Numberofdoors:1-2 • Loadperrack(Kg): 25-60 • Lighting:Interiorilluminationwithledlight. • Insidedoor:Transparentacrylic • Outsidedoor:Well Insulated • Power:Workson230vacsinglephase50hz • Displaydigitaldisplay • Warranty:3Years(On-Site) , Video Endoscopy Machine-- • Should Be Veterinary Specific & Suitable For Companion Animal As Well As Large Animal. • Gastroscopeshouldhaveintegratedvideocamera With High Source. • Shouldalsohavemedical Colonoscope. • Insertion Tube Should Be Of Extremely Short Tip With Outer Diameter Of 8.4 Mm, Working Length Should1050 Mm, Working Channel Should Be 2.8 Mm. • Should Have 4- Way Deflection (Upward 210°, Downward 90°, Left 100° And Right 100°). • Fieldofviewshouldbe120°. • Depthofviewshouldbe3-100Mm. • Should Be Provided Along With Carrying Case, Caps For Working Channel, Irrigation Tube, Cleaningbrush And Cleaning Valve. • Shouldhavebiopsyforcepsandforeignbody Forceps. • Hd Camera System Should Be Compatible With Both Flexible And Rigid Endoscope. • Should Have Internal Medical Grade Recorder For Capturing Full Hd. • Patients Informationshouldbe Editable Anddisplayed In Monitor. • Shouldbesuppliedwithmedicalgrademonitor. • Shouldbesuppliedwithtrolley. • Patients Informationshouldbe Editable Anddisplayed In Monitor. • Shouldbesuppliedwithmedicalgrademonitor. • Shouldbesuppliedwithtrolley. • Shouldprovide3-Yearwarrantyandshouldhave Oemserviceengineerpostedattripuraforregular Promptservice(Documentstobe Enclosed) , Elisareader Withaccessories Including (Absorbance Microplate Readers, Software And A Fully-Automated Elisa Processor And Powerbackup.)-- • Filter Based Elisareader With Halogen Lamp As Light Source And Single Channel Optics/ Single Detector With Silicon Photo Detectors For Reliable Results. • Halogenlampshouldhaveminimumusageoption, I.E. It’S Should Get ‘On’ While Reading And Should Be ‘Off’Mode Even The Instrument Is On Standby Mode. • Should Be Compatible To Wavelength Range From 340 To 850 Nm, Which Must For Various Elisa Applications. • Shouldhaveeasyaccess8positionfilterwheel. • Instrument Should Be Supplied With 3 Standard Filters Of 405Nm, 450Nm And 620Nm. • Should Have Automatic Calibration And Selfdiagnostics Of Any Possible Error In Optical Alignment Before Each Program Reading. • Should Able To Read 96 Well Format Microwell Plate In 6 Seconds. • The Instrument Should Run In Stand-Alone Mode Orwithcomputer&Dataanalysissoftware Controlled. • Internal Software (Standalone Mode) Should Have All The Basic Application Related To Elisa Like Quality Control, Qualitative Classification, Standard Graph Etc. • Computer Software Should Be Supplied With Unlimited User Licenses And Should Have Reading As Well As Data Analysis Option Including Standardcurve Fit, Qualitative Classifications, Quality Controletc. • Systemshouldabletoruninstand-Alonemodeusing 4.5-Inchcolourdisplayand Keypad. • The Instrument Should Have A Memory Of 99 Inbuilt Protocolsinstand-Alonemodeand100resultmemory. • The Instrument Should Have 2 Usb Ports, One For The Easy Data Transfer And Another To Connect Printer Directly To The Unit. • System Should Have Usb Port For External Printer Connectivity Option For The Data Printout. • Instrument Should Be Either Ce Mark/ Ivd/ Usfda, Authorized Certificate From Notified Body Should Be Submitted. • One(1)Year Warranty O 3Kvaonlineups O Attached With Suitable Computer Desktop With Powerbackupwithfollowingconfigurationintel I3processor12th Gen, 8Gb Ram, Ssd, Ddr-4, Hard Disk 1 Tb, 15 Monitor, Keyboard, Mouse With Computer Ups Dataanalysissoftware: O Software Should Have Option For Area Selection. I. E Differentprotocolsatdifferentareaofthesameplate. O Database Based Software To Run Backups Of All Data, Restore Back Up Data (In Case Of Hardware Failure Of Original Computer). O Singlesoftwareprogramshouldallowanynumberof Measurement Steps Within The Program. O Datashouldbeabletoexportinformatssuchas Excel,Pdf,Xml,Ornote. , Incubator (Bacteriological)-- • Controller: Microprocessor Pid Digital Controller For Temperature Control • Timer:99Hr59minorcontinuousselectable • Innermaterial:Stainlesssteel304 • Outer Material: Mild Steel With Antibacterial Powder Coated Paint • Door:Glasswindowviewingmetaldoublewalled Door • Insulation: Double Wall Construction & Mineral Wool Insulation To Avoid Heat Loss • Innerdimensions:455X455x610mm(Wxdxh) • Capacity:6Cu.Ft(Table-Topmodel) • Temperaturerange:Ambient+5°Cto100°C • Temperature Accuracy:±1°Ccontrolledwithpt-100 Sensor • Temperatureuniformity:±1°C • Heaterload:600Wheaterresistancenichromewire • Aircirculationfan:Maintainuniformtemperature • Display:Leddigitaldisplay • Shelves (Removable): Ss 304 Made 03Nos. Wire Mesh Shelves • Safety:Over/Undertemperaturealarm&Cut-Off, Over Current Breaker • Electricsupply:220V,50Hz;With3-Pinsafetyplug And Power Cord • Warranty:3Yrs , Micro Haematocrit Centrifuge-- • Motorcapacity:24X75mmlengthcapillarytubes. • Speedrangeof500-12,000Rpm,Max.Rcf12000/ 14118G. • Independentcontrolofspeedandtime. • Easyoperationwithintuitivemenuanddigitaldisplay. • Max.Speedof 12,000Rpm. • Rotor:Hctrotorwithscrewonlid. • Weight:4-8Kg • Warranty:2Years(On-Site) , Micropipetteset--• Kitshouldinclude0.2-2,2-20,20-200&100-1000Ul Single Channel Pipettes, 1Pipette Stand (6 Position), 4 Sizes Tip Boxes With Tips, Reagent Reservoir Sample, Calibration Certificate. • Alsoincludedextratwopipettes1-10Ul,10-100Ul. • Fullyautoclavable • Advancedvolumegearingmechanism • Shouldhavelarge,Easy-To-Readdisplay • Double-Action Pipetting Button With A Rotating Upper Part, For Easy And Light Volume Setting. • Shouldbelightweight,Leastrsi(Repetitivestrain Injury) • Ergonomicdesign,Separatesofttouchtipejector • Inlabcalibrationandeasymaintenance,Easytoopen • Superblowoutpistonforsmallvolumestoensure Delivery Of Micro Size Drops • Shouldbeisoandusfdacertified(Provide Document) • 2Years Warranty , Desktop Computer-- • Operatingsystem:Windows11pro(Original) • Processor:Intel®Core™I5-13500 (Upto3.8Ghz With25mbcacheand6 Cores) • Memory:8Gbddr4-3200Mhzram • Storage:1Tbhdd+512Gbssd • Graphics:Intel®Uhdgraphics770 • Chipset:Intel® • Connectivityandcommunications:Intel®Wi-Fi6e And Bluetooth® 5.3 Wireless Card • Ports: 1 Headphone/ Microphone Combo; 1 Usb Type- C 10Gbps Signalling Rate; 3 Usb Type-A • 10Gbpssignallingrate • Videoconnectors:1-Hdmi1.4;1-Displayport1.4; 1- Vga • Monitor:Size-60.5Cm,Fhd(1080P)Withips Display • Pointingdevice:Wiredmouse • Keyboard:Wired • Should Include Original Preinstalled Latest Version Microsoft Office Home, & Student 2021 Lifetime Subscription • Ups:1,000Va,360W,Withleast15-Minuteback-Up • Warranty:03Years(On-Site). , Scalding Tank (Stainlesssteel)-- • Material: Stainless Steel: 304Ssgrade- Cylindricalshapedwith Legs-Drum1.2 Mm Thickness With Lid. • Drumcapacity–50–60Litres • Capacity–2-3Birds • Electricalheater–2Kwcapacity • Power:230-240V/50Hz. • Controlpanelwithdigitaltemperatureindicators.Type: Electrically Operated , Clinical Haematologyanalyser(Five Part)--• Fullyautomatic Veterinary Hematologyanalyzer For Analysis Of Different Species Of Domestic, Pet Animals, Lab Animals And Wild Animals’ Blood. • Flow Cytometry (Fcm), Tri-Angle Laser Scatter, Chemical Dye Method And Independent Basophilchannel Etc./ And Other Advance Method • 5 Parts For Different Wbc Count With Veterinary Animal Species Specific Software • Minimum23parameters:Wbc,Lym%,Mon%,Neu %, Eos%, Bas%, Lym#, Mon#, Neu#, Eos#, Bas#, Rbc, Hgb, Hct, Mcv, Mch, Mchc, Rdw-Cv, Rdw-Sd, Plt, Mpv, Pdw, Pct. • 3Histogramforrbc,Wbc&Plt • 3Scattergramsforwbcdifferential • Samplevolume<20?L,Tfttouchscreendisplay • Canprocess Upto60samplesperhour • Storageupto30,000Samplereport. • Keyboard,Externalinkjetprinter,Supportedbyuser- Defined Report Format Print Out (A4 Size) • Fullsetconsumablereagentsuppliedalongwith Instrument. • Onlineups1kva,360Wwith15-30Minbackup • Shouldprovide3yearswarrantyandshouldhaveoem Serviceengineerpostedattripuraforregularand Prompt Service (Documents To Be Submitted Along With Enit) , Electric Stunner--• Stunner With Ss Tongs To Operate On Sheep/ Goats And Pigs. • Thecontrolboxwithanaloguedisplayfor0–110 Voltsand2ampere. • Withdigitaltimer. • Stunnerwithcontrolbox. , Portablecolouranalyser-- • Digitalcolourmeterthatmeasurescolourinlab • Colourspace:Cielab • Colourdifferenceformula:?E*Ab • Measurementcaliber:F8mm • Lightsource:D65 • Sensor:Photodiodearray • Observer:Cie10°Standardobserver • Measurementrange:L:0To100 • Repeatedaccuracy:?E<0.1 • Tabledifference:?E<0.2 • Measurementinterval:1Sec. • Storage Capacity: Type Sample Data: 100 Groups With Testing Sample Data: 100 Groups • Lifetimeofbulb:Minimum5years. • Displayscreen:Tfttruecolour 2.8Inch@(16:9) • Language:English , Mufflefurnace--• Temperaturerangesupto1000oc,Workingtemperature Upto950oc,Size19x16x18(L X W X H)Inches, 220/ 230-Volt, Warranty: 02 Year (On-Site) , Mixer Grinder--• No Of Jars: 3; Jar Size: Wet Jar (1.5 Litres), Multipurposejar(1Litre),Chutneyjar(0.3Litres);Jar Material: Stainless Steel; Body Material: Abs; Blade Material: Stainless Steel; Speed Control: 3 Speed Control+Pulse,Wattage:1000W;Voltage:230V, Warranty:01Year(On-Site) , Labwilly Mill--• Bodymaterial.Ms,Powersource.Electric,Voltage- 240V,Frequency-50Hz,Powerconsumption-0.75 Kw,Load.43Kg. , Digital Camera--• 24.1-Megapixelaps-Ccmossensor&Digic4+ Image Processor • 9-Pointafwith1centrecross-Typeafpointand Standard Iso 100 - 6400 (Expandable To 12 800) • Displaysize:3Inch • Lenstype:Opticalzoom • Digitalcameralensef-S18-55Mmf/3.5-5.6Isii , Exhibition Panel/Panel Board With Stand--• Size:10X4feet • Usage/Applicationexhibition • Size10x4feet • Framematerialaluminum • Mountingfreestanding • Shaperectangular • Thickness2.5-10Mm , Rms Speakers-- • 100Watts,Sta-150,Withtripodstandofheight Adjustment: 3.5Ft-6.5 Ft, • Loadcapacity;40Kg, • Warranty:1Years , Wireless Microphone-- Audiooutput:0110Mv/600,Freq.Resp:50-15000Hz, Antenna: Detachable Through Bnc Connector, Power: Ac-220-240Foracadopter,Modulationmade: Fm(F3e), Warranty: 1 Years. , Amplifier-- Ac&24Vdcoperated,250Watts,6Mic&2Aux, Warranty: 1 Year. , Publicaddress With Speaker--Pasystemwithabuilt-Inamplifier,Bluetooth,Usb, Recording,Andecho.Elegant,Rugged&Easytocarry Amplifier Which Delivers 20W (Max.) Output Power. Built-Indigitalmp3playerwithrecordingandbluetooth Function. Built-In Digital Echo. , Interactive Board--Size-75With4kultrahighdefinition(3840X2160) @ 60Hz With Oled Display Technology With 8 Ms Response Time, 20 Points Ir Multi Touch Interface, 3 Hdmi, 4 Usb, Bare Dimension Of 1990 X 114 X 1201 Mm With <320W Power Consumption, Build In Android 8.0 With < 3 Gb Ram And < 32 Gb Rom With Ops
Contract Date: Dec 03, 2025 Contract Value : 76.81 Lakh
Government Departments No of Bidders 14
50.
Defence #8315061 AOC
Tender For Provision Of Flame Proof Ac,S, Isolation Transformer And False Ceiling Under Ge Af Gorakhpur.; 1 Taking down existing split air conditioner of capacity 1.5 /2 Tonfrom site alongwith indoor and out door split air conditioner, making good disturebed surfaces and diposited to MES store yard complete all as specified and directed. 2 Supply and installation, commissioning ofFlame proof split unit “Hazards Cool” Explosion Proof Split Type Air Conditioner Unit 2 TR ,Operating voltage supply 230V, Single Phase, 50Hz , Condensing Unit :To be kept in hazardous area along with Emerson make hermetically sealed Explosion Proof compressor of R407 C, Eco-friendly. Condensing Motor, condensing coil made up of Aluminum blue fins duly coated with specialist chemical to prevent refrigerant leakage GI cabinet will be used to integrate the components of condensing unit, Cooling Unit : Indoor Wall mounted Unit to be kept in hazardous area of split type cooling unit. Cooling Motor, condensing coil with Copper tubes and Aluminum blue fins duly coated with specialist chemical to prevent refrigerant leakage.GI cabinet will be used to integrate the components of cooling unit, Flameproof Control Panel: Lamps 230 VAC – 3 nos. (Power ON, Compressor ON, Cooling motor ON, With temperature indicator cum controller, 2 relay output, FLP RTD PT100 3wire / FLP Thermostat MCB, Contactor & Overload relay for protection compressor and condensing motor cooling motor Incomer MCB will be provided. Classification Area – Zone I & II, Gas Group IIA, IIB & IIC with Dust Protection Zone 21 & 22 , Certification: Certified by CIMFR Dhanbad, PESO (Nagpur) , Accessories: MS Standing frame,3/8’’ copper pipe with insulation Sleeve, 5/8’’ copper pipe with insulation sleeve, 25mm Water Drain pipe, 2.5 Sqmm X 3 core copper flexible cable for main power supply, indoor and outdoor units including all Civil work complete all as specified and directed.Make : Shyam (Cat No. SSPL/HC/508) , Sudhir or other equivalent make as approved by GE. 3 Supply and fix Flame proof Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5 KVA complete all as specified and directed. 4 Supply and fixing Commercial Dehumidifier with Moisture removal 30 degree Celcius, 80% RH, 240 V, 50 Hz, Maintain level- 30% RH- 80% RH, Refrigerent- R410, Water tank capacity- 20L, Air Flow-550 Cum/Hr, WDE-603T including all connection of pipe/hose to wall and complete all as specified and directed. 5 Supply and fixing Commercial Humidifier with air Volume- 10 Kg/Hr, 230V, 50 Hz, Auto control, Humidity display, Humidity control 10% to 95%, Volume of water Tank- 10L including all connection of pipe/hose to wall andcomplete all as specified and directed. 6 M&Lpoint wiring complete copper conductor 1.5 Sq mm size (nominal area)PVC insuloatedFRLS unsnearned cable 1100 V grade conforming to IS 694 drawn in and including 1.6 mm thick concealed ERW stove enameled rigid steel conduit conforing to IS:9537 of size not less than 25mm dia including flame proof fittings such as MS junction bos,. MS coupling uninors bends, reducers inspection albow seeling conduits, plugs etc and also including single core standed copper conductor 1.5 Sq mm PVC insulated unsheathed FRLS cable as earth wire to common earth adn connected to earth doily and body of the flameproof lumiaires an drawn in the same concealed conduit complete all as specified and directed for following:-(a)One flame proof light/ fan point controlled by single pole one way 10 Amp flame proof ON-OFF rotary switch. 7 All as per item No-6 above here in before but with copper conductor cable for one 3 pin socket outlet, 16 amp independent, with cable 4 sqmm size complete all as specified and directed. 8 S & F of Switch flame proof rotary type with termination box in LM6, 16A, single pole 250V complete all as specified and directed. Make : Shyam, Sudheer complete all as specified and directed. 9 S & F of Flame proof switch socket & plug combined in LM6 cable termination box in LM6, 32A, 250V, 2P+earth complete all as specified and directed. Make : Shyam, Sudheer 10 Supply and fix for, flame proof, weather proof enclosure made of cast aluminium alloy LM6 weather proof IP65, finished inside and outside with light grey epoxy powder coating for MCB distribution board, three phase and neutral, with incoming and outgoing terminal chamber, bus bar chamber comprising of 04 (Four) Nos or OEM recommendation copper bus bars of suitable rating, with and including separate MCB chambers suitable for accommodating 09 (Nine) Nos. of 10 Amps MCB SP C curve, 03 (Three) Nos. of MCB SP 20 Amps C curve and 01 (One) No. of MCB TPN 63 Amps C curve, including cable glands terminals, hardware mounting arrangement including necessary welding, cutting and drilling work for the DBs to be fixed on channel of the frame with necessar nut, bolt and washers with channel/ plate of suitable size etc. all as per Cat No.SSPL/RCP/109 of make Sudhir or equivalent model of make Crompton Greaves/ Bajaj as apprived complete all as specified and directed. Note : rate inclusive all spare part and MCB 11 Supply and fixing 1-999 Minutes IN OFF Digital Timer switch for dual output AC (2 TON) timer switch for 2 Air Conditioner for energy saving alternately one by one continuously 220 Volt , 30 Amps, Micro control based technnology, setup 1 to 999 Miniutes both 2 load, cyclic timer switch, LED indicator for ON/OFF, live display of remain time, simple ON/OFF time setting, Max voltage 280V, Min Voltage 180 Volts, Display seven segment ( 3 Digits) 12 Supply,Installation,Testing & Commissioning of Digital Grounding Device 120kA, 1 phase 3 wire Portable type with built in Low Impedance Grounding & bonding system. Provides100% protection against Lightning Surges,static Charge,Noises,ESD,EPR.It eliminates all abnormal electrical disturbances which always enters from power lines and alway sensuring clear bonding potential (earth to Neutral voltage) less than 1.0V to allequipment connected hereafter. It is having a digital 6 digit lightening surge counter alsohaving tested capability to handle lightning impulse current upto 45KA,self-health visualstatus indicator. It offers low resistance to all devices connected hereafter with inpermissible distance. It has facility to display Resistance values and rela time ground-neutral offered to all equipment connected hereafter. It is Pre- wired,pulverulent bodypainted, metallic enclosure always tobe connectedin parallelto thepower supply circuit.DGD is tested & certified from CPRI, MIL STD810G, IEC61000-6-1, IEC 61000-6-3,IEC61643-11-2011 & confirming to ISO 9000 & ISO 14001-2015 & CE.Make in India,Model:DSS-MII-1P3-120 13 S & FFramedworksuch as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framedbalusters; walk ways; railings; framework of gate lights and similar work con- forming to Fe.290.Gde-E-165 complete all as specified and as directed. 14 Supply and fixing Humen Body static discharge device display unit Flameproof, , Max test point 1.5V DC, IP66, Power 230 Volts AC mounted on wall complete all as specified and directed. 15 M&L Earthing complete with galvanised steel earth plate electrode 60 cm x60 cm x 6 mm thick buried directly in ground ,(Earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level ,connected to and including galvanised iron earth wire 4 mm dia by means ofnut, bolts, check nuts and washers of galvanised iron or steel complete all as specified and directed including testing on completion including the material and labour of the following : - (a) Excavation and earth work for drilling hole for electrode in any type of Soil. (b) PCC pit in cement concrete 1:2:4 type B-1, Pre cast RCC cover with suitable handle 40 mm thick in PCC 1:2:4 type B-1, reinforced with welded steel wire fabric weighing not less than1.87 Kg/ Sq meter. (c) Funnel with watering pipe of GI 20 mm nominal bore light grade and lugs etc complete all as specified and directed (d) 15 mm nominal bore medium grade GI protection pipe 5 meter long for protection of earthing lead complete all as specified and directed. (e) Requisite quantity of common salt and charcoal. (f) Testing of earthing. 16 S & F Aluminium strip 25 x 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above groundcomplete all as specified. 17 Supply and fixing 20 mm bore Low density polyethylene (LDPE) drain pipe of pressure rating 6 kgf/sqcm for GI Strip complete all as specified and directed. 18 S & F of LED light fitting 1/2x 16 watt flame proof , CMRI certified recommended for gas / vapour/ group of IIA& IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminium housing with heat resistant toughened glass with LED tube light fixture , driver, holder, connector etc . complete with all accessories prewired and including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. Make : Shyam, Sudheer 19 M&L Switch piano flushtype single pole, one way 5 Amps 230 Volts AC circuit complete all as specified & directed by Engr-in-Charge. 20 S&F recess mounting LED luminaire of size 2x2white 34 watt, 230 voltsfor ceiling with driver connector block etc complete with all accessories prewired and including connecting up with twin core twisted flexible copper conductor of suitable size complete all as specified and directed. Make:- Havellsor equivalent in Bajaj /CG./Shakti 21 Supply, instalation, testing and commissioning of indoor automatic/servo voltage controller single phase, 50Hz (confirming as per BIS-9815: Part 1: 1994 reaffirmed 2009) Naturally air cooled of 6 KVA, unbalanced type, copper wound, digital display type, Relay free smooth and slient operation with first filling of Transformer oil having following specification :-(i) Input Voltage 170-270V or as per ground requirement (ii) Output voltage stabilized at any designed/desired votage 230+-1% adjustable (iii) No distortion in wave form (iv) Response time not to exceed 10 mili seconds (v) Sensitivity +-1% (vi) Rate of conection 70 volt/ second for single phase (vii) Duty cycle continuous 24x7, Effciency more than 95%(viii Digital display voltmeter and amp meter of suitable rating Protections (ix) Over load/short circuit protection (x) High/low voltage cut off (xi) By pass arrangement in case of emergency 22 Supply , Installation, testing and commissioning of indoor type of oil cooled isotation transformer 6 KVA step-III, IS-2026 single phase, metalic body unbalanced type, copper wound with standard fitings and accessiones, input voltage of 220 volt , output voltage 220 voltIP-42, vector group Dyn-11, of frequency 50Hz and with following description including first fill of transformer Oil IS 335 ISI marked :-(a) Method of cooling air cooled (b) Rato-1:1 (c) Insulation class-Class E (d) Winding Temperature-Less than 55 C (e) Full load losses Less than 5% (f) No load tosses Less than 0.5%(h) Potential difference between Earth to Neutral voltage- Less than 01 voltNate:- (a) in addtion to the above all standard fittings to be provided as per ISI noms. 23 Supply,Installation,Testing & Commissioning of Digital Grounding Device 120 kA, 1 phase 3 wire Portable type with built in Low Impedance Grounding & bonding system. Provides100% protection against Lightning Surges,static Charge,Noises,ESD,EPR. It eliminates all abnormal electrical disturbances which always enters from power lines and always ensuring clear bonding potential (earth to Neutral voltage) less than 1.0V to all equipment connected hereafter. It is having a digital 6 digit lightening surge counter also having tested capability to handle lightning impulse current upto 45KA,self-health visual status indicator. It offers low resistance to all devices connected hereafter with in permissible distance. It has facility to display Resistance values and rela time ground-neutral offered to all equipment connected hereafter. It is Pre- wired,pulverulent bodypainted, metallic enclosure always tobe connectedin parallelto the power supply circuit.DGD is tested & certified from CPRI, MIL STD810G, IEC61000-6-1, IEC 61000-6-3,IEC61643-11-2011&confirming to ISO 9000 & ISO 14001-2015 & CE.Make in India, Model:DSS-MII-1P3-120 24 S&F Aluminium Torsion Spring Perforated Ceiling System :Supply & fixing of torsion spring Tile Ceiling System in true Horizontal Level comprising of Tile of 600mm wide and 600mm/1200mm long manufactured out of 0.7mm thick Aluminium sheet with perforation of 1.8 mm dia. having 20% open area. The metal ceiling panels shall be downward accessible with a minimum of four (4) torsion springs per panel. The Tile will be manufactured through process of seven roller sheets levelling to achieve flat panels. Torsion Spring panel with two side & two end legs die formed and punched to receive torsion springs (min two springs each end or side) for secure engagement into Tee Grid main runners which are factory punched to receive torsion springs. Tiles will be square edged. The metal ceiling panels shall be downward accessible with a minimum of four (4) torsion springs per panel. Main Runners of Size 24 x 38 made of 0.35 mm thick (Minimum) Sheet placed 600mm CC with cross T of size 24x32 to be placed 600/1200 mm between the Main Runner & wall angle of size 24x24x 0.40 mm and fixing false ceiling tiles of approved texture in the grid including required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc.Main T runners to be suspended from ceiling using galvanized mild steel items (galvanizing @ 80 grams per sqm) i.e. 12x50 mm long dash fasteners, 6 mm dia fully threaded hanger rod upto 1000 mm length and L-shape level adjuster of size 76x25x25x1.6 mm fixed with grid and Z cleat of size 25x37x25x1.6mm thick with precut hole on both 25mm flange to pierce into 12x50mm or even bigger size dash fastener. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in charge.Paint Finish: The Tile shall be Polyester powder coated in white colour. Panel will be electrostatically powder coated using electromechanical Reciprocator and automatic conveyer system, cured with gas catalytic technology.Acoustic Felt: Non-woven felt glued over the perforation for sound absorption to achieve NRC of 0.70. Make: BSR Calsi Ceilings/ Saint Govain 25 Supply only in replacement motor, single phase for 200/250mm Exhaust fan as per sample complete all as specified and directed.
Contract Date: Oct 31, 2025 Contract Value : 32.95 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 6
Uttar Pradesh View Result →
TenderDetail
Loading tenders