View Bid Results For Access Road Tenders

We found 1555 Bid Results related to access road tenders. You can find Contractor details who won access road tenders along with contract details in Bid awards announcements section.

Filters
Stage
1097
290
168
Tender Publishing Platform
66
1489
State / UT
36
443
129
123
108
108
93
81
64
51
50
31
26
25
23
23
22
21
21
20
15
15
9
9
8
7
5
5
4
3
3
3
2
2
1
1
1
Contract Value
482
182
578
311
Publish Date
7
0
0
0
0
Sector
28
507
277
242
85
58
56
52
45
41
35
34
28
21
13
13
10
5
5
4
4
4
3
3
3
3
2
1
1
Ownership
6
799
307
247
198
2
2
Within keyword
Active filters:
Showing 1–32 of 1555 tenders matching your filters
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
Himachal Pradesh View Result →
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 6
Uttar Pradesh View Result →
Contract Date: Ref. Documents Contract Value : 2.55 Lakh
Local Bodies No of Bidders 1
Contract Date: Jun 29, 2026 Contract Value : 19.82 Lakh
Government Departments No of Bidders 1
Maharashtra View Result →
6.
Housing Urban and Rular Development #11398313 AOC
Laying Of Access Road From Pullela Gopichand Academy Road To Eptri
Contract Date: Ref. Documents Contract Value : 26.90 Lakh
Local Bodies No of Bidders 1
Contract Date: Ref. Documents Contract Value : 3.95 Lakh
Local Bodies No of Bidders 1
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 3
Uttar Pradesh View Result →
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 7
Uttar Pradesh View Result →
11.
Water Resources and Irrigation #11342285 AOC
Amrut-Supply, Erecting And Commissioning Of Various Pump Sets, Other Necessary Equipment For 107 Mld Sewerage Treatment Plant At Muttathara-Supply, Erecting And Commissioning Of Various Pump Sets, Other Necessary Equipments For 107 Mld Sewerage Treatment Plant At Muttathara-Sewerage Work- 1 SUPPLY, ERECTING AND COMMISSIONING OF PUMP SETS 2 OD149149/2023-2024:Supply, Erecting and Commissioning of 75 HP non clog pump set for RAS (Head – Up to 20 M) 3 OD149154/2023-2024:Supply, Erection and Commissioning of 5 HP non clog pump set for WAS (Total Head :14 M ) 4 OD149153/2023-2024:Supply, Erecting and Commissioning of 5 HP centrifugal dewatering pump set for RAS 5 OD17699/2025-2026:Supply, Erecting and Commissioning of80 HP Submersible pump set for inlet(Head : Up to 20 M) 6 OD18102/2025-2026:Supply, installation, and commissioning of minimum 100 LPH RO water purifier of standard make with 304-grade stainless steel skid and housing, comprising multi-stage purification system including pre-filter, sediment filter, activated carbon filter, RO membrane, UV disinfection unit, auto-flush system, and mineral cartridge; suitable for continuous commercial use and delivering safe, high-quality drinking water. 7 OD18758/2025-2026:Supply of 10 HP portable submersible sludge pump, 3-phase, suitable for handling slurry and sewage, maximum head up to 20 meters, solid handling capacity up to 50 mm, abrasion-resistant impeller, thermal protection, 15 m power cable, and 30 meters of heavy-duty discharge hose (100 mm dia) with quick couplings. 8 Supply and installation soft starter and motorized chain pulley 9 OD149170/2023-2024:Supply of motorized chain pulley block with 3-ton lifting capacity and 10-meter lift height, featuring electric motorized operation with electromagnetic or disc brake system, pendant control for easy operation, limit switches for safety, and overload protection, conforming to IS/ISO standards. 10 OD16970/2025-2026:Supply and installation of soft starter for MCC unit ( For 60 HP motor XS4000,115A,M200-525VACC110/ 220VAC), MNX140 3P 240V CONTACTOR and SEMI CONDUCTOR FUSE 170M3015 11 OD18097/2025-2026:Supplying, fixing, and testing 50W LED hanging type well glass light, weatherproof (IP65) 12 OD18264/2025-2026:Supply and installation of 10-meter hot-dip galvanized double-arm octagonal street light pole with 2×120W LED luminaires, including internal wiring, weatherproof junction box, connections, and earthing. Complete with foundation bolts and RCC pedestal. Includes supply, erection, and commissioning 13 Installation of CCTV camera 14 OD16801/2025-2026:Supplying & fixing HIKVISION 5 MP Varifocal IP Bullet Camera CAMERA 15 OD16892/2025-2026:Supplying, fixing and commissioning 4MP IP DOME CAMERA 16 OD16891/2025-2026:Supplying, fixing and commissioning HIKVISION 4MP IP BULLET CAMERA 40M 17 OD16890/2025-2026:Supplying, fixing and commissioning HIKVISION 32CH NVR 18 OD16889/2025-2026:Supplying, fixing and commissioning 8 PORT POE SWITCH 19 OD16888/2025-2026:Supplying & fixing 6U RACK & ACCESSORIES 20 OD16887/2025-2026:Supplying & fixing 9U RACK& ACCESSORIES 21 OD16886/2025-2026:Supplying & fixing CAMERA BOX 22 OD16885/2025-2026:Supplying & fixing CAT6 CABLE & PIPING (including excavation) 23 OD16884/2025-2026: Supplying and fixing pole with all accessories. 24 OD16920/2025-2026:Supplying and fixing 55-inch, 4K, LED, Smart TV (Samsung/LG/Sony) 25 OD16919/2025-2026:Supplying & fixing RECEIVER & TRANSMITTER UNIT 26 OD16918/2025-2026:Supplying & fixing L & T EXTENSION 5MTR 27 OD16917/2025-2026:Supplying & fixing 5 PORT GIGABYTE SWITCH 28 OD16916/2025-2026:Supplying & fixing HDMI CABLE 3MTR 29 OD16915/2025-2026:Supplying & fixing RACK & PIPE ACCESSORIES, 30 OD16914/2025-2026:INSTALLATION CHARGE FOR CAMERA& NVR 31 OD16913/2025-2026:Supplying & installation of rack 32 New Road formation: Tarring inside STP compound 33 3.6:Excavation for roadwork in soil with hydraulic excavator of 0.9 cum bucket capacity including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross sections, and transporting to the embankment location within all lifts and lead upto 1000m 34 4.1.B.1:Construction of granular sub-base by providing graded material, spreading in uniform layers with a motor grader on a prepared surface, mixing by mix in-place method with rotavator at OMC, and compacting with a vibratory roller to achieve the desired density, complete as per clause 401. Grading-V - For sub-base cum drainage layer - Mix in Place Method 35 4.12:Providing, laying, spreading and compacting graded stone aggregate to Wet Mix Macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver in sub- base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density. 36 5.1.a:Providing and applying primer coat with bitumen emulsion ( SS) on prepared surface of granular Base including clearing of road surface and spraying primer at the rate of 0.70 - 1.0 kg/sqm using mechanical means. 37 5.2.a:Providing and applying tack coat with bitumen emulsion( RS) using emulsion pressure distributor at the rate of 0.20 - 0.30 kg per sqm on the prepared bituminous surface cleaned with mechanical broom. 38 OD18679/2025-2026:Providing 40mm premixed chipping carpet over BT surface with departmental broken stones after thoroughly cleaning the base with wire brushes, brooms and applying a priming coat of hot bitumen @2.50Kg/10m2 and spreading the hot premix of 0.32m3 of 24mm, 0.22m3 of 12mm departmental metal mixed with 22.08Kg of bitumen per 10m2, rolling to dense surface, then spreading the seal coat comprising of 0.09m3 of 6mm metal mixed with 8.64kg of bitumen per 10m2 and rolling again including cost of bitumen, fuel, hire charges machineries etc. complete excluding the cost of 24mm ,12mm ,6mm metal(Total usage of bitumen 33.22 Kg per 10m2) (I.R.C 3.4.2) 39 OD18716/2025-2026:Supplying and stacking 24mm hard blue granite broken stone in standard heaps-for measurement(IRC 3.2. 1.a) 40 55.2:Supplying and stacking 12mm hard blue granite broken stone in standard heaps for measurement(IRC 3.2.1.a) 41 55.3:Supplying and stacking 6mm hard blue granite broken stone in standard heaps for measurement(IRC 3.2.1.a) 42 Infrastructure Improvement Works at STP 43 OD17712/2025-2026:Supply and installation of UV-resistant HDPE with 12mm mesh ( 2meter height) for durability. Support poles are galvanized iron pipes (2-inch dia, 6 ft height) for stability. Stainless steel clamps & UV-resistant plastic ties ensure secure fitting. Concrete footing with excavation and earthwork provides pole stability. Skilled labor ensures proper installation 44 OD17711/2025-2026:Supply and spray a non-toxic, bio-friendly herbicide or a selective herbicide, with an application rate of 5 to 10 liters per hectare, ensuring effective weed control over an area of 1 hectare. 45 2.31:Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared 46 2.32:Clearing grass and removal of the rubbish up to a distance of 50 m outside the periphery of the area cleared. 47 4.2.5:Providing and laying cement concrete in retaining walls, return walls, walls ( any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts,buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor, etc. up to floor five level, excluding the cost of centering, shuttering and finishing:1:3:6 ( 1 cement : 3 coarse sand :6 graded stone aggregate 20 mm nominal size) 48 4.3.1:Centering and shuttering including strutting, propping etc. and removal of form work for:Foundations, footings, bases for columns 49 5.22.4:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelHot rolled deformed bars 50 OD17710/2025-2026:Supply & installation of high-quality polyester sun control film with UV-blocking, heat resistance (99% UV, 60% heat rejection), 2–4 mil thickness, bubble-free installation, and 5-year warranty. 51 OD17709/2025-2026:Fire extinguishers (10L dry powder and 4.5kg CO₂) shall be installed as per IS: 2190 with inspection cards. Fire buckets with MS stands, safety posters, and caution notices in Malayalam and English shall be provided for compliance. 52 Providing roofing for DG, Inlet outdoor panels and mechanical screener 53 100.98.1009:Engaging Fitter ( grade 1). 54 15.2.1:Demolishing cement concrete manually / by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in-Charge.Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) 55 2.8.1:Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil 56 50.10.1:Steel work in built up G I tubular ( round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting,fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete 57 50.10.2:Steel work for purlin/single section with G I pipes including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete 58 50.12.1.1:Providing & fixing PVC corrugated roofing sheets of good quality up to any pitch, including fixing with polymer coated J or L hooks, bolts & nuts 8 mm dia G. I plain/ bitumen washers complete but excluding the cost of purlins, rafters, trusses etc. The sheets shall be opaque or translucent, clear or pigmented, textured or smooth as specified. 59 4.3.1:Centering and shuttering including strutting, propping etc. and removal of form work for:Foundations, footings, bases for columns 60 4.1.3:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size) 61 Replacement of leaking flanged pipes inside the inlet well 62 OD17790/2025-2026:Supply, conveyance, and fixing of 300mm double flanged DI K9 pipe, including scaffolding, fabrication if required (cutting, flange welding), and providing necessary fittings, nuts, bolts, rubber gaskets, and insertion rubber sheets for proper and safe installation at site. 63 OD17835/2025-2026:Dismantling existing 300 mm DI pipes carefully using crane/manual handling with all necessary safety measures, and stacking the removed materials within 50 meters as directed by the Engineer-in-Charge 64 Provision forEntry of Trucks from Rear Side of STP 65 15.7.1:Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge.In mud mortar 66 2.6.1:Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil 67 4.1.8:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size) 68 7.1.1:Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand) 69 5.1.3:Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) 70 50.6.1.1:Solid block masonry using pre cast solid blocks ( factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 part 1 of 1979 for foundation and plinth with thickness 20 cm and above in: CM 1:6 ( 1 cement : 6 coarse sand) etc complete 71 50.6.1.2:Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement: 6 coarse sand) etc complete. 72 13.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) 73 13.43.1:Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer 74 13.82.1:Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound) content less than 50 grams/ litre, of approved brand and manufacture including applying additional coats wherever required, to achieve even shade and colour.One coat 75 10.26.3:Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approves steel primer.G.I. pipes 76 13.52.1:Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturers specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work 77 Security room (4m x 3m) at back entrance of STP 78 2.8.1:Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil 79 4.1.8:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size) 80 50.6.1.1:Solid block masonry using pre cast solid blocks ( factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 part 1 of 1979 for foundation and plinth with thickness 20 cm and above in: CM 1:6 ( 1 cement : 6 coarse sand) etc complete 81 5.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete 82 5.1.2:Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size 83 50.6.1.2:Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement: 6 coarse sand) etc complete. 84 5.3:Reinforced cement concrete work in beams, suspended floors, roofs, having slope up to 150 landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (Zone III) : 3 graded stone aggregate 20 mm nominal size). 85 5.9.3:Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform 86 5.9.5:Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers 87 13.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) 88 5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more 89 OD17944/2025-2026:Providing and fixing glazed shutters for doors, windows and clerestory windows using 4mm thick float glass panes including MS grill with suitable spacing and ISI marked M.S pressed butt hinges bright finished of required size with necessary locking arrangements. 90 OD17947/2025-2026:Electrical work including internal lighting, fan, switches, DB, concealed wiring, and one external LED light with pole/bracket for night visibility, complete with connections, fittings, and testing as per direction of Engineer-in-Charge. 91 13.61.1:Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work
Contract Date: Jun 23, 2026 Contract Value : 2.52 Crore
Local Bodies No of Bidders 1
13.
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 3
Uttar Pradesh View Result →
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 10
Maharashtra View Result →
15.
Tourism #11320518 Technical Bid
Tender For Tourism Development Work Of Shri Ramjanaki Temple, Kotawari In Shahjahanpur District.-1 Earth Work In Excavation By Mechanical Means (Hydraulic Excavator)/ Manual Means Over Areas (Exceeding 30 Cm In Depth, 1.5 M In Width As Well As 10 Sqm On Plan) Including Getting Out And Disposal Of Excavated Earth Lead Upto 50 M And Lift Upto 1.5 M, As Directed By Engineer-Incharge. All Kinds Of Soil Dsr-2.6.1 170.25 Cum 133.12 127.80 21757.52 In All Kind Of Soil Upto 1.5M To 3.0M. Depth 2.6.1+2.26.1 18.74 Cum 228.22 219.09 4106.24 In All Kind Of Soil Upto 3.0M To 4.5M. Depth 2.6.1+(2.26.1* 2) 6.37 Cum 323.31 310.38 1977.88 2 Excavation Of Foundation In Ordinary Soil (Loam Clay Or Sand) Including Lift Upto 1.50 Meter And Lead Upto 30 Meter And Including Filling, Watering And Ramming Of Excavated Earth Into The Trenches Or Into The Space Between The Building And Sides Of Foundation Trenches Or Into The Plinth And Removal And Disposal Of Sur-Plus Earth As Directed By The Engineer Incharge Up To A Distance Of 30 Meters From The Foundation Trenches. Dsr-2.1.1 35.61 Cum 97.38 93.49 3329.14 3 Filling Available Excavated Earth (Excluding Rock) In Trenches, Plinth, Sides Of Foundations Etc. In Layers Not Exceeding 20Cm In Depth, Consolidating Each Deposited Layer By Ramming And Watering, Lead Up To 50 And For All Lift. Dsr-2.25 8.70 Cum 147.00 141.12 1227.84 4 Excavating, Supplying And Filling Of Local Earth (Including Royalty) By Mechanical Transport Upto A Lead Of 5Km Also Including Ramming And Watering Of The Earth In Layers Not Exceeding 20 Cm In Trenches, Plinth, Sides Of Foundation Etc. Complete Dsr-2.25(A) 55.60 Cum 525.36 504.34 28041.40 5 Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level : 1:4:8 (1 Cement : 4 Coarse Sand (Zone-Iii) Derived From Natural Sources : 8 Graded Stone Aggregate 40 Mm Nominal Size Derived From Natural Sources) Dsr-4.1.8 70.78 Cum 5108.83 4904.47 347162.56 6 Supplying And Filling In Plinth With Sand Under Floors, Including Watering, Ramming, Consolidating And Dressing Complete. Dsr-2.27 26.31 Cum 1592.76 1529.05 40229.27 7 Diluting And Injecting Chemical Emulsion For Postonstructional Anti-Termite Treatment (Excluding The Cost Of Chemical Emulsion) : Treatment Of Soil Under Existing Floors Using Chemical Emulsion @ One Litre Per Hole, 300 Mm Apart Including Drilling 12 Mm Diameter Holes And Plugging With Cement Mortar 1 :2 (1 Cement : 2 Coarse Sand) To Match The Existing Floor: With Chlorpyriphos/Lindane E.C. 20% With 1% Concentration Dsr-2.35.3.1 194.47 Sqm 232.53 223.23 43411.24 8 Reinforced Cement Concrete Work In Beams, Suspended Floors, Roofs Having Slope Up To 15° Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Window Sills, Staircases And Spiral Stair Cases Above Plinth Level Up To Floor Five Level, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement With 1:1.5:3 (1 Cement : 1.5 Coarse Sand(Zone-Iii) Derived From Natural Sources : 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources). Dsr-5.3 82.66 Cum 8628.83 8283.68 684729.10 9 Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement - All Work Up To Plinth Level : 1:1.5:3 (1 Cement : 1.5 Coarse Sand (Zone-Iii) Derived From Natural Sources : 3 Graded Stone Aggregate 20 Mm Nominal Size De Rived From Natural Sources) Footing Dsr-5.1.2 21.98 Cum 6784.08 6512.72 143149.60 10 Reinforced Cement Concrete Work In Walls (Any Thickness), Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc. Above Plinth Level Up To Floor Five Level, Excluding Cost Of Centering, Shuttering, Finishing And Reinforcement : 1:1.5:3 (1 Cement : 1.5 Coarse Sand(Zone-Iii) Derived From Natural Sources : 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources) Dsr-5.2.2 22.97 Cum 8139.44 7813.86 179484.39 Abstract Of Cost Delhi Schedule Of Rate Effective From 12/07/2023 X (0.735X106/107X1.03) Has Been Followed. Proposed Tourism Development Of Ramjanki Temple At Kotawari, Tilhar, Sahjahanpur, U.P. 11 Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For Lintels, Beams, Plinth Beams, Girders, Bressumers And Cantilevers Dsr-5.9.5 257.49 Sqm 552.28 530.19 136518.66 12 Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For Suspended Floors, Roofs, Landings, Balconies And Access Platform Dsr-5.9.3 407.10 Sqm 695.41 667.60 271778.96 13 Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For Foundations, Footings, Bases Of Columns, Etc. For Mass Concrete Dsr-5.9.1 63.96 Sqm 294.10 282.34 18058.37 14 Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For Columns, Pillars, Piers, Abutments, Posts And Struts Dsr-5.9.6 208.86 Sqm 720.95 692.11 144554.66 15 Brick Work With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 In Foundation And Plinth In: Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) Dsr-6.1.1 16.84 Cum 5527.80 5306.69 89341.45 16 Brick Work With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 In Foundation And Plinth In: Cement Mortar 1:6 (1 Cement : 6 Coarse Sand) Dsr-6.1.2 51.30 Cum 5349.01 5135.05 263427.92 17 Providing And Laying Damp-Proof Course 50Mm Thick With Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand (Zone-Iii) Derived From Natural Sources : 4 Graded Stone Aggregate 20Mm Nominal Size Derived From Natural Sources). Dsr-4.11 2.14 Sqm 371.80 356.93 763.83 18 Providing & Applying A Coat Of Residual Petroleum Bitumen Of Grade Of Vg-10 Of Approved Quality Using 1.7Kg Per Square Metre On Damp Proof Course After Cleaning The Surface With Brushes And Finally With A Piece Of Cloth Lightly Soaked In Kerosene Oil. Dsr-4.13 44.55 Sqm 109.61 105.22 4687.75 19 Brick Work With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 In Superstructure Above Plinth Level Up To Floor V Level In All Shapes And Sizes In : Cement Mortar 1:6 (1 Cement : 6 Coarse Sand) Dsr-6.4.2 80.04 Cum 6829.23 6556.06 524747.32 20 Half Brick Masonry With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 In Superstructure Above Plinth Level Up To Floor V Level. Cement Mortar 1:4 (1 Cement :4 Coarse Sand) Dsr-6.13.2 60.18 Sqm 842.82 809.11 48692.17 21 Steel Reinforcement For R.C.C. Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Above Plinth Level. Thermo-Mechanically Treated Bars Of Grade Fe-500D Or More Dsr-5.22A.6 186.64 Qtl 8088.48 7764.94 1449250.34 22 15 Mm Cement Plaster On Plinth Side Of Single Or Half Brick Wall Of Mix : 1:4 (1 Cement: 4 Coarse Sand) Dsr-13.5.1 65.74 Sqm 308.80 296.45 19488.62 23 15 Mm Cement Plaster On Rough Side Of Single Or Half Brick Wall Of Mix: 1:6 (1 Cement: 6 Coarse Sand) Dsr-13.5.2 252.10 Sqm 296.50 284.64 71758.35 24 12 Mm Cement Plaster Of Mix : 1:6 (1 Cement: 6 Coarse Sand) Dsr-13.4.2 609.85 Sqm 257.73 247.42 150888.63 25 Add For Plaster Drip Course/ Groove In Plastered Surface Or Moulding To R.C.C. Projections. Dsr-5.30 315.01 Rm 58.80 56.45 17781.09 26 Cement Concrete Flooring 1:2:4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate) Finished With A Floating Coat Of Neat Cement, Including Cement Slurry, But Excluding The Cost Of Nosing Of Steps Etc. Complete. 40 Mm Thick With 20 Mm Nominal Size Stone Aggregate Dsr-11.3.1 29.40 Sqm 460.63 442.21 13000.95 27 Cement Plaster Skirting Up To 30 Cm Height, With Cement Mortar 1:3 (1 Cement : 3 Coarse Sand), Finished With A Floating Coat Of Neat Cement.18 Mm Thick Dsr-11.6.1 3.35 Sqm 496.52 476.66 1596.81 26 Providing And Laying Vitrified Floor Tiles In Different Sizes (Thickness To Be Specified By The Manufacturer) With Water Absorption Less Than 0.08% And Conforming To Is: 15622, Of Approved Make, In All Colours And Shades, Laid On 20 Mm Thick Cement Mortar 1:4 (1 Cement : 4 Coarse Sand), Jointing With Grey Cement Slurry @ 3.3 Kg/ Sqm Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete. Size Of Tile 600X600 Mm Dsr-11.41.2 137.75 Sqm 1165.05 1118.45 154065.99 27 Providing And Laying Vitrified Tiles In Different Sizes (Thickness To Be Specified By Manufacturer), With Water Absorption Less Than 0.08 % And Conforming To |.S. 15622, Of Approved Make, In All Colours & Shade, In Skirting, Riser Of Steps, Over 12 Mm Thick Bed Of Cement Mortar 1:3 (1 Cement: 3 Coarse Sand), Jointing With Grey Cement Slurry @ 3.3 Kg/ Sqm Including Grouting The Joint With White Cement & Matching Pigments Etc. Complete. Size Of Tile 600X600 Mm Dsr-11.46.2 10.17 Sqm 1217.25 1168.56 11884.22 28 Providing And Fixing 1St Quality Ceramic Glazed Floor Tiles Conforming To Is : 15622 (Thickness To Be Specified By The Manufacturer ) Of Approved Make In All Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Engineer-In-Charge In Skirting, Risers Of Steps And Dados Over 12 Mm Thick Bed Of Cement Mortar 1:3 (1 Cement: 3 Coarse Sand) And Jointing With Grey Cement Slurry @ 3.3Kg Per Sqm Including Pointing In White Cement Mixed With Pigment Of Matching Shade Complete. Dsr-11.37A 148.53 Sqm 812.00 779.52 115781.77 29 Providing And Laying Rectified Glazed Ceramic Floor Tiles Of Size 300X300 Mm Or More (Thickness To Be Specified By The Manufacturer), Of 1St Quality Conforming To Is : 15622, Of Approved Make, In Colours White, Ivory, Grey, Fume Red Brown, Laid On 20 Mm Thick Cement Mortar 1:4 (1 Cement: 4 Coarse Sand), Jointing With Grey Cement Slurry @ 3.3Kg/ Sqm Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete. Dsr-11.39 4.40 Sqm 997.47 957.57 4213.30 30 Chequerred Precast Cement Concrete Tiles 22 Mm Thick In Footpath & Courtyard, Jointed With Neat Cement Slurry Mixed With Pigment To Match The Shade Of Tiles, Including Rubbing And Cleaning Etc. Complete, On 20 Mm Thick Bed Of Cement Mortar 1:4 (1 Cement: 4 Coarse Sand). Ordinary Cement Without Any Pigment 11.20.4 6.12 Sqm 792.24 760.55 4654.54 31 Providing And Fixing Panelled Or Panelled And Glazed Shutters For Doors,Windows And Clerestory Windows, Fixing With Butt Hinges Of Required Size With Necessary Screws, Excluding Panelling Which Will Be Paid For Separately, All Complete As Per Direction Of Engineer-In-Charge. (Note: Butt Hinges And Necessary Screws Shall Be Paid Separately) 35 Mm Thick Dsr-9.5.1.1 6.30 Sqm 3083.86 2960.50 18651.18 32 Providing And Fixing Panelled Or Panelled And Glazed Shutters For Doors,Windows And Clerestory Windows, Fixing With Butt Hinges Of Required Size With Necessary Screws, Excluding Panelling Which Will Be Paid For Separately, All Complete As Per Direction Of Engineer-In-Charge. (Note: Butt Hinges And Necessary Screws Shall Be Paid Separately) 30 Mm Thick Dsr-9.5.1.2 83.22 Sqm 2810.38 2697.97 224524.67 33 Providing And Fixing Isi Marked Flush Door Shutters Conforming To Is : 2202 (Part I) Non-Decorative Type, Core Of Block Board Construction With Frame Of 1St Class Hard Wood And Well Matched Commercial 3 Ply Veneering With Vertical Grains Or Cross Bands And Face Veneers On Both Faces Of Shutters: 35 Mm Thick Including Isi Marked Stainless Steel Butt Hinges With Necessary Screws Dsr-9.21.1 15.33 Sqm 1794.43 1722.65 26408.23 34 Providing 40X5 Mm Flat Iron Hold Fast 40 Cm Long Including Fixing To Frame With 10 Mm Diameter Bolts, Nuts And Wooden Plugs And Embedding In Cement Concrete Block 30X10X15Cm 1:3:6 Mix (1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20Mm Nominal Size). Dsr-9.53 128.00 Nos 171.63 164.77 21090.11 35 Providing And Fixing M.S. Grills Of Required Pattern In Frames Of Windows Etc. With M.S. Flats, Square Or Round Bars Etc. Including Priming Coat With Approved Steel Primer All Complete. Fixed To Steel Windows By Welding Dsr-9.48.1 937.05 Kg 164.32 157.75 147816.54 36 Providing And Fixing T-Iron Frames For Doors, Windows And Ventilators Of Mild Steel Tee-Sections, Joints Mitred And Welded, Including Fixing Of Necessary Butt Hinges And Screws And Applying A Priming Coat Of Approved Steel Primer. Fixing With 15X3 Mm Lugs 10 Cm Long Embedded In Cement Concrete Block 15X10X10 Cm Of C.C. 1:3:6 (1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20 Mm Nominal Size). Dsr-10.13.1 100.80 Kg 106.27 102.02 10283.67 37 Providing And Fixing Angle Iron Frames For Doors, Windows And Ventilators Of Mild Steel Angle Sections Of Size 35X35X5 Mm, Joints Mitred And Welded By Angle Iron 35X35X5 Mm Or 35X 5 Mm Flat Pieces To The Existing T-Iron Frame Or To The Wall With Dash Fastener, Including Fixing Of Necessary Butt Hinges And Screws And Applying A Priming Coat Of Approved Steel Primer, All Complete As Per The Direction Of Engineer-In-Charge. Dsr-10.31 125.00 Kg 97.87 93.96 11744.60 38 Providing And Fixing Stainless Steel ( Grade 304) Railing Made Of Hollow Tubes, Channels, Plates Etc., Including Welding, Grinding, Buffing, Polishing And Making Curvature (Wherever Required) And Fitting The Same With Necessary Stainless Steel Nuts And Bolts Complete, I/C Fixing The Railing With Necessary Accessories & Stainless Steel Dash Fasteners , Stainless Steel Bolts Etc., Of Required Size, On The Top Of The Floor Or The Side Of Waist Slab With Suitable Arrangement As Per Approval Of Engineer-Incharge, (For Payment Purpose Only Weight Of Stainless Steel Members Shall Be Considered Excluding Fixing Accessories Such As Nuts, Bolts, Fasteners Etc.). Dsr 10.28 133.33 Kg 579.28 556.11 74146.05 39 Providing Wood Work In Frames Of Doors, Windows, Clerestory Windows And Other Frames, Wrought Framed And Fixed In Position With Hold Fast Lugs Or With Dash Fasteners Of Required Dia & Length (Hold Fast Lugs Or Dash Fastener Shall Be Paid For Separately).(Sal Wood) Dsr-9.1.2 1.61 Cum 87387.28 83891.79 135065.79 40 Fixing Of Door, Windows/Ventilators Chaukhats In Position. (A) Door Chaukhats Above 1.5 Sqm To 5.0Sqm Mr 19.00 Nos 150.00 144.00 2736.00 (B) Window Chaukhats Above 1.5 Sqm 12.00 Nos 100.00 96.00 1152.00 (C) Ventilator Chaukhats 7.00 Nos 50.00 48.00 336.00 41 Finishing Walls With Premium Acrylic Smooth Exterior Paint With Silicone Additives Of Required Shade: New Work (Two Or More Coats Applied @ 1.43 Ltr/10 Sqm Over And Including Priming Coat Of Exterior Primer Applied @ 2.20 Kg/10 Sqm) Dsr-13.47.1 407.00 Sqm 128.32 123.19 50137.46 42 Distempering With Oil Bound Washable Distemper Of Approved Brand And Manufacture To Give An Even Shade : New Work (Two Or More Coats) Over And Including Water Thinnable Priming Coat With Cement Primer Dsr-13.41.1 434.15 Sqm 139.23 133.66 58030.01 43 Providing And Applying White Cement Based Putty Of Average Thickness 1 Mm, Of Approved Brand And Manufacturer, Over The Plastered Wall Surface To Prepare The Surface Even And Smooth Complete. Dsr-13.80 841.15 Sqm 117.03 112.35 94505.07 44 Providing And Fixing Isi Marked Oxidised M.S. Sliding Door Bolts With Nuts And Screws Etc. Complete :250X16 Mm Dsr-9.62.2 11.00 Nos 145.27 139.46 1534.05 45 Providing And Fixing Isi Marked Oxidised M.S. Tower Bolt Black Finish, (Barrel Type) With Necessary Screws Etc. Complete : 250X10 Mm Dsr-9.63.1 21.00 Nos 62.92 60.41 1268.53 200X10 Mm Dsr-9.63.2 65.00 Nos 52.05 49.97 3247.81 46 Providing And Fixing Isi Marked Oxidised M.S. Handles Conforming To Is:4992 With Necessary Screws Etc. Complete :100 Mm Dsr-9.66.2 54.00 Nos 24.41 23.44 1265.50 47 Providing And Fixing Bright Finished Brass Hanging Type Floor Door Stopper With Necessary Screws, Etc. Complete Dsr-9.82 1.00 Nos 91.23 87.59 87.59 48 Providing And Laying Integral Cement Based Water Proofing Treatment Including Preparation Of Surface As Required For Treatment Of Roofs, Balconies, Terraces Etc Consisting Of Following Operations: (A) Applying A Slurry Coat Of Neat Cement Using 2.75 Kg/Sqm Of Cement Admixed With Water Proofing Compound Conforming To Is. 2645 And Approved By Engineer-In-Charge Over The Rcc Slab Including Adjoining Walls Upto 300 Mm Height Including Cleaning The Surface Before Treatment. (B) Laying Brick Bats With Mortar Using Broken Bricks/Brick Bats 25 Mm To 115 Mm Size With 50% Of Cement Mortar 1:5 (1 Cement : 5 Coarse Sand) Admixed With Water Proofing Compound Conforming To Is : 2645 And Approved By Engineerin- Charge Over 20 Mm Thick Layer Of Cement Mortar Of Mix 1:5 (1 Cement :5 Coarse Sand ) Admixed With Water Proofing Compound Conforming To Is : 2645 And Approved By Engineerin- Charge To Required Slope And Treating Similarly The Adjoining Walls Upto 300 Mm Height Including Rounding Of Junctions Of Walls And Slabs. (C) After Two Days Of Proper Curing Applying A Second Coat Of Cement Slurry Using 2.75 Kg/ Sqm Of Cement Admixed With Water Proofing Compound Conforming To Is : 2645 And Approved By Engineer-In-Charge. (D) Finishing The Surface With 20 Mm Thick Jointless Cement Mortar Of Mix 1:4 (1 Cement :4 Coarse Sand) Admixed With Water Proofing Compound Conforming To Is : 2645 And Approved By Engineer-In-Charge Including Laying Glass Fibre Cloth Of Approved Quality In Top Layer Of Plaster And Finally Finishing The Surface With Trowel With Neat Cement Slurry And Making Pattern Of 300X300 Mm Square 3 Mm Deep. (E) The Whole Terrace So Finished Shall Be Flooded With Water For A Minimum Period Of Two Weeks For Curing And For Final Test.“All Above Operations To Be Done In Order And As Directed And Specified By The Engineer-In-Charge : With Average Thickness Of 120 Mm And Minimum Thickness At Khurra As 65 Mm Dsr-22.7.1 198.55 Sqm 1263.41 1212.87 240815.58 49 Finishing With Deluxe Multi Surface Paint System For Interiors And Exteriors Using Primer As Per Manufacturers Specifications : Painting Steel Work With Deluxe Multi Surface Paint To Give An Even Shade. Two Or More Coat Applied @ 0.90 Ltr/ 10 Sqm Over An Under Coat Of Primer Applied @ 0.80 Ltr/ 10 Sqm Of Approved Brand And Manufacture Dsr-13.48.3 144.65 Sqm 128.02 122.90 17777.47 50 Finishing With Deluxe Multi Surface Paint System For Interiors And Exteriors Using Primer As Per Manufacturers Specifications : Painting Wood Work With Deluxe Multi Surface Paint Of Required Shade. Two Or More Coat Applied @ 0.90 Ltr/10 Sqm Over An Under Coat Of Primer Applied @0.75 Ltr/10 Sqm Of Approved Brand And Manufacture Dsr-13.48.2 209.70 Sqm 132.18 126.90 26610.03 51 Providing & Fixing Panes Of Glass With Equal Or Equivalent I.S.I Marked Quality Putty. Brads And Springs And Including Supply Of All Materials And Labour Etc Complete . 3.8 To 4.7 Mm Thick Dsr-10.30.1 44.76 Sqm 805.96 773.72 34631.80 52 Supply And Fixing Of Drop Down Rail / Grab Bars Mr 4.00 Nos. 4400.00 4224.00 16896.00 53 Providing, Driving With Hydraulic Piling Rigs With Power Units And Installing Driven Cast-In-Situ Reinforced Cement Concrete Piles Of Grade M-25 Of Specified Diameter And Length Below The Pile Cap, To Carry Safe Working Load Not Less Than Specified, Excluding The Cost Of Steel Reinforcement But Including The Cost Of Shoe And The Length Of Pile To Be Embedded In The Pile Cap Etc. All Complete. (Length Of Pile For Payment Shall Be Measured From Top Of Shoe To The Bottom Of Pile Cap) : 400 Mm Dia Piles Dsr-20.1.1 48.00 Rm 2075.18 1992.17 95624.30 54 Stone Work (Machine Cut Edges) For Wall Lining Etc. (Veneer Work) Upto 10 Metre Height, Backing Filled With A Grout Of Average 12 Mm Thick Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) Including Pointing In White Cement Mortar 1:2 (1 White Cement : 2 Stone Dust) With An Admixture Of Pigment Matching The Stone Shade : (To Be Secured To The Backing And The Sides By Means Of Cramps And Pins Which Shall Be Paid For Separately) : 30 Mm Thick Dsr-8.14.1.5 50.74 Sqm 3971.79 3812.92 193478.98 55 Stone Work In Plain Ashlar In Super Structure Upto Floor Five Level In Cement Mortar 1:6 (1 Cement : 6 Coarse Sand) Including Pointing With Cement Mortar 1:2 (1 White Cement : 2 Stone Dust) With An Admixture Of Pigment Matching The Stone Shade Both Face Dressed Red Sand Stone Dsr-7.12.1.1 3.56 Cum 51218.78 49170.03 175241.97 56 Extra For Stone Work Ashlar Sunk Or Moulded Or Sunk And Moulded Or Carved In : Triangular Or Square Or Rectangular Pillars Dsr-7.21.1 3.56 Cum 2834.15 2720.79 9696.89 57 Providing And Fixing Stainless Steel Cramps Of Required Size And Shape For Anchoring Stone Wall Lining To The Backing Or Securing Adjacent Stones In Stone Wall Lining In Cement Mortar 1:2 (1 Cement : 2 Coarse Sand), Including Making The Necessary Chases In Stone And Holes In Walls Wherever Required. Dsr-8.15 99.58 Kg. 535.78 514.35 51219.04 58 Stone Work (Machine Cut Edges) For Wall Lining Etc. (Veneer Work) Upto 10 Metre Height, Backing Filled With A Grout Of Average 12 Mm Thick Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) Including Pointing In White Cement Mortar 1:2 (1 White Cement : 2 Stone Dust) With An Admixture Of Pigment Matching The Stone Shade : (To Be Secured To The Backing And The Sides By Means Of Cramps And Pins Which Shall Be Paid For Separately) :Red Sand Stone - Exposed Face Machine Cut And Table Rubbed With Rough Backing. 50Mm Dsr 8.14.1.3 37.80 Sqm. 4342.28 4168.59 157572.62 59 Providing And Fixing Copper Pins 7.5 Cm Long 6 Mm Diameter For Securing Adjacent Stones In Stone Wall Lining In Cement Mortar 1:2 (1 Cement : 2 Coarse Sand), Including Making The Necessary Chases. Dsr 8.16 30.00 Nos. 32.92 31.61 948.21 60 Providing And Fixing Stone Jali 40 Mm Thick Throughout In Cement Mortar 1:3 (1 Cement : 3 Coarse Sand), Including Pointing In White Cement Mortar 1:2 (1 White Cement : 2 Stone Dust) With An Admixture Of Pigment, Matching The Stone Shade, Jali Slab Without Any Chamfers Etc. Red Sand Stone Dsr 7.33.1 4.50 Sqm. 11198.29 10750.35 48376.59 61 Stone Work, Plain In Copings, Cornices, String Courses And Plinth Courses, Upto 75 Mm Thick In Cement Mortar 1:6 (1 Cement : 6 Coarse Sand), Including Pointing With White Cement Mortar 1:2 (1 White Cement : 2 Stone Dust) With An Admixture Of Pigment Matching The Stone Shade.: Red Sand Stone Dsr 7.32.1 0.47 Cum. 70303.46 67491.32 31720.92 62 Carving & Engraving Work On Red Sand Stone (Labour Only) M.R. 9.73 Sqm. 15615.00 14990.40 145856.59 63 Manufacturing, Supplying And Fixing Retro Reflective Overhead Signage Boards Made Up Of 2 Mm Thick Aluminium Sheet, Face To Be Fully Covered With High Intensity And Encapsulated Lens Type Heat Activated Retro Reflective Sheeting Conforming To Type - Iii Of Astm-D-4956-01 As Approved By Engineer-In-Charge, Letters, Borders Etc. As Per Irc : 67-2001 In Silver White With Blue Colour Back Ground And With High Intensity Grade, Pasted On Substrate By Pressure Sensitive Adhesive Backing Which Shall Be Activated By Applying Pressure Conforming To Class Ii Of Astm-D-4956-01 And Fixing The Same To The Plate Of Structural Frame Work By Means Of Suitable Sized Aluminium Alloys, Rivets Or Bolts & Nuts @ 300 Mm Centre To Centre All Along The Periphery As Well As In Two Vertical Rows Along With Theft Resistant Measures, Including The Cost Of Painting With Two Or More Coats Of Epoxy Paint In Grey Colour On The Back Side Of Aluminium Sheet Including Appropriate Priming Coat. The Rate Includes The Cost Of Rounding Off The Corners, Lowering Down The Structural Frame Work From The Gantry, Fixing And Erecting The Same In Position All Complete As Per Drawings, Specification And Direction Of The Engineerincharge.( Structural Frame Work Including M.S. Plate To Be Provided Separately. Rectangular Area Of The Sheet Only Shall Be Measured For Payment). Overhead Informatory Road Signage Dsr 16.60.1 8.64 Sqm. 4409.78 4233.39 36576.45 64 Providing And Fixing 18 Mm Thick Gang Saw Cut, Mirror Polished, Premoulded And Prepolished, Machine Cut For Kitchen Platforms, Vanity Counters, Window Sills, Facias And Similar Locations Of Required Size, Approved Shade, Colour And Texture Laid Over 20 Mm Thick Base Cement Mortar 1:4 (1 Cement : 4 Coarse Sand), Joints Treated With White Cement, Mixed With Matching Pigment, Epoxy Touch Ups, Including Rubbing, Curing, Moulding And Polishing To Edges To Give High Gloss Finish Etc. Complete At All Levels. Dsr 8.2.2.2 34.45 Sqm 3852.10 3698.01 127396.50 65 Making Plinth Protection 50 Mm Thick Of Cement Concrete 1:3:6 (1 Cement : 3 Coarse Sand (Zone-Iii) Derived From Natural Sources : 6 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources) Over 75 Mm Thick Bed Of Dry Brick Ballast 40 Mm Nominal Size, Well Rammed And Consolidated And Grouted With Fine Sand, Including Necessary Excavation, Levelling & Dressing & Finishing The Top Smooth. Dsr-4.17 6.00 Sqm 561.96 539.48 3236.87 66 Providing And Laying Factory Made Chamfered Edge Cement Concrete Paver Blocks In Footpath, Parks, Lawns, Drive Ways Or Light Traffic Parking Etc, Of Required Strength, Thickness & Size/ Shape, Made By Table Vibratory Method Using Pu Mould, Laid In Required Colour & Pattern Over 50 Mm Thick Compacted Bed Of Sand, Compacting And Proper Embedding/Laying Of Inter Locking Paver Blocks Into The Sand Bedding Layer Through Vibratory Compaction By Using Plate Vibrator, Filling The Joints With Sand And Cutting Of Paver Blocks As Per Required Size And Pattern, Finishing And Sweeping Extra Sand. Complete All As Per Direction Of Engineer-In-Charge.80 Mm Thick C.C. Paver Block Of M-35 Grade With Approved Colour Design And Pattern Dsr-16.91.2 207.07 Sqm 818.60 785.85 162723.31 1 Providing And Fixing Water Closet Squatting Pan (Indian Type W.C. Pan) With 100Mm Sand Cast Iron P Or S Trap, 10 Litre Low Level White P.V.C. Flushing Cistern With Manually Controlled Device (Handle Lever) Conforming To Is : 7231, With All Fitting And Fixtures Completed Including Cutting And Making Good The Walls And Floors Wherever Required.White Vitreous China Orissa Pattern W.C. Pan Of Size 580X440 Mm With Integral Type Foot Rests 17.1.1 2.00 Nos. 5075.38 4872.36 9744.73 2 Providing And Fixing White Vitreous China Pedestal Type Water Closet (European Type W.C. Pan) With Isi Marked White Solid Plastic Seat And Lid, 10 Litre Low Level White P.V.C. Flushing Cistern With Manually Controlled Device (Handle Lever), Conforming To Is : 7231, With All Fittings And Fixtures Complete Including Cutting And Making Good The Walls And Floors Wherever Required. W.C. Pan With Isi Marked White Solid Plastic Seat And Lid 17.2.1 3.00 Nos. 4886.50 4691.04 14073.11 3 Providing And Fixing Wash Basin With C.I. Brackets, 15 Mm C.P. Brass Pillar Taps, 32 Mm C.P. Brass Waste Of Standard Pattern, Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls Wherever Require A) White Vitreous China Flat Back Wash Basin Size 550X 400 Mm With Single 15 Mm C.P. Brass Pillar Tap. 17.7.4 4.00 Nos. 1409.35 1352.98 5411.91 4 Providing And Fixing White Vitreous China Flat Back Or Wall Corner Type Lipped Front Urinal Basin Of 430X260X350 Mm And 340X410X265 Mm Sizes Respectively With Automatic Flushing Cistern With Standard Flush Pipe And C.P. Brass Spreaders With Brass Unions And G.I Clamps Complete, Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls And Floors Wherever Required A) One Urinal Basin With 5 Litre White P.V.C. Automatic Flushing Cistern 17.4.1 3.00 Nos. 4918.90 4722.14 14166.42 5 Providing And Fixing Flexible P.V.C. Waste Pipe For Sink Or Wash Basin Including Pvc Waste Fittings Complete. Flexible Pipe 17.28.2 A) 32Mm Dia 17.28.2.1 4.00 Nos. 89.66 86.07 344.29 B) 40Mm Dia 17.28.2.2 2.00 Nos. 89.66 86.07 172.15 6 Providing And Fixing 600X450 Mm Beveled Edge Mirror Of Superior Glass (Of Approved Quality) Complete With 6 Mm Thick Hard Board Ground Fixed To Wooden Cleats With C.P. Brass Screws And Washers Complete. 17.31 4.00 No. 1205.92 1157.69 4630.74 7 Providing And Fixing Cp Brass Single Lever Lelephonic Wall Mixture Of Quality & Make And As Per Thedirection Of Enginer-Incharge. A) 15Mm Dia Nominal Dia. 17.22B 2.00 Each 5205.39 4997.17 9994.34 8 Providing And Fixing 8 Mm Dia C.P./S.S. Jet With Flexible Tube Upto 1 Meter Long With S.S. Triangular Plate For Eureopean Type W.C. Of Quality And Make As Approved By Engineer-In-Charge. 15Mm Nominal Bore 17.16A 2.00 Each 261.85 251.38 502.76 Sanitary Fixtures & Accessories : I 9 Providing And Fixing Ptmt Towel Rail Complete With Brackets Fixed To Wooden Cleats With Cp Brass Screws With Concealed Fittings Arrangement Of Approved Quality And Colour. 600 Mm Long Towel Rail With Total Length Of 645 Mm, Width 78 Mm And Effective Height Of 88 Mm, Weighing Not Less Than 190 Gms. Dsr-17.73.2 1.00 Each 531.69 510.43 510.43 10 Providing And Fixing Ptmt Soap Dish Holder Having Length Of 138Mm, Breadth 102Mm, Height Of 75Mm With Concealed Fitting Arrangements, Weighing Not Less Than 106 Gms. Dsr-18.65 1.00 Each 83.58 80.24 80.24 11 Providing And Fixing C.P. Brass Ablution Health Faucet Assembly With 1.0 M Long Braided Pvc Hose With Mounting Bracket Fixed On Wall Complete.[For Ewc]-Make-Jaquar Ald565 Mr 2.00 Each 1705.00 1636.80 3273.60 12 Providing And Fixing C.P. Brass Two-Way Angle Valve For Ewc Points & For Fixing Ablution Health Faucet Of Approved Quality Conforming To Is:8931. 15 Mm Nominal Bore-Essco Sqt 526A Mr 2.00 Each 1335.00 1281.60 2563.20 1 Providing And Fixing On Wall Face Unplasticised Rigid Pvc Rain Water Pipes Conforming To Is : 13592 Type A Including Jointing With Seal Ring Conforming To Is : 5382 Leaving 10 Mm Gap For Thermal Expansion . (I) Single Socketed Pipes. A) 110Mm Diameter 12.41.2 31.30 Mtr 283.04 271.72 8504.80 2 Making Khurras 45X45 Cm With Average Minimum Thickness Of 5 Cm Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate Of 20 Mm Nominal Size) Over Pvc Sheet 1M X 1 M X 400 Micron, Finished With 12 Mm Cement Plaster 1:3 (1 Cement : 3 Coarse Sand) And A Coat Of Neat Cement,Punning,Rounding The Edges And Making And Finishing The Outlet Complete. A) 110Mm 12.22 7.00 Nos. 223.68 214.73 1503.13 3 Providing And Fixing Unplasticised -Pvc Pipe Clips Of Approved Design To Unplasticised - Pvc Rain Water Pipes By Means Of 50X50X50Mm Hard Wood Plugs, Screwed With M.S. Screws Of Required Length Including Cutting Brick Work And Fixing In Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) And Making Good The Wall Etc. Complete. A) 110Mm 12.43.2 20.00 Nos. 278.47 267.33 5346.54 4 Providing And Fixing On Wall Face Unplasticised Rigid Pvc Rain Water Pipes Conforming To Is : 13592 Type A, Including Jointing With Seal Ring Conforming To Is : 5382, Leaving 10 Mm Gap For Thermal Expansion, (I)Single Socketed Pipes. 110 Mm Diameter 12.41.2 Rm. 283.04 271.72 5 Providing And Fixing To The Inlet Mouth Of Rain Water Pipe Cast Iron Grating 15 Cm Diameter And Weighing Not Less Than 440 Grams. Dsr-12.44 8.00 Nos. 41.02 39.38 315.06 6 Providing And Fixing In Floor And Wall Face Ringfit Upvc Astral Ultradrain Conventional System For Soil And Waste Water Pipes Conforming To (Hsn Code: 3917) Type B Including Jointing With Seal Ring. (I) Double Socketed Pipes. A) 110Mm Dia P.V.C. Pipe Nsr 20.00 Rm. 485.00 465.60 9312.00 B) 90Mm Dia P.V.C. Pipe Nsr 25.00 Rm. 390.00 374.40 9360.00 6 Providing & Fixing Upvc Floor Trap Of Self Cleansing Design With Cp Jali Complete In All Respects. (Make : Supreme / Finolex / Prince) P-Trap Type Floor Trap 110 X 90 Mm Nsr 12.00 No. 195.00 187.20 2246.40 7 Providing And Fixing On Wall Face Unplasticised - Pvc Moulded Fittings/Accessories For Unplasticised Rigid Pvc Pipes Including Jointing With Seal Ring Leaving 10 Mm Gap For Thermal Expansion.. (Make : Supreme / Finolex / Prince) Door Tee 110X110X110 Mm Nsr 2.00 No. 280.00 268.80 537.60 110X110X90 Mm Nsr 2.00 No. 200.00 192.00 384.00 Bend 110 Mm Nsr 2.00 No. 170.00 163.20 326.40 Soil Waste & Vent Pipes And Fittings - Ii 90 Mm Nsr 2.00 No. 160.00 153.60 307.20 1 Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineer In Charge.Lls Etc. (Internal Work) I) Exposed On Wall A) 32Mm Nominal Dia Pipe 18.9.4 30.00 Rm. 328.94 315.78 9473.44 3 Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings Including Fixing The Pipe With Clamps At 1.00M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer In Charge. (Internal Work) I) Exposed On Wall A) 25Mm Dia Nominal Outer Dia Pipes 18.7.3 20.00 Rm. 301.15 289.11 5782.13 4 Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings I/C Fixing The Pipe With Clamps At 1.00M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement And The Cost Of Cutting Chases And Making Good The Same Including Testiang Of Joints Complete As Per Direction Of Engineer In Charge. Concealed Work Including Cutting Chases And Making Good The Walls Etc. A) 15Mm Dia Nominal Outer Dia Pipes 18.8.1 70.00 Rm. 373.34 358.40 25088.28 B) 20Mm Dia Nominal Outer Dia Pipes 18.8.2 20.00 Rm. 403.19 387.06 7741.18 C) 25Mm Dia Nominal Outer Dia Pipes 18.8.3 Rm. 470.42 451.60 5 Providing & Fixing G.I. Pipes Complete With G.I. Fittings & Clamps Including Cutting & Making Good The Walls Etc. (Internal Work) I) Exposed On Wall A) 25Mm Dia Nominal Bore (Medium Duty) Dsr-18.10.3 20.00 Rm. 413.76 397.21 7944.21 Ii) Concealed Pipe Including Painting With Anticorrosive Bitumatic Paint, Cutting Chases And Making Good The Wall. A) 15Mm Dia Nominal Bore Dsr-18.11.1 15.00 Rm. 435.32 417.91 6268.65 2 Painting G.I. Pipes And Fittings With Synthetic Enamel White Paint Over A Ready Mixed Priming Coat, Both Of Approved Quality For New Work. A) 15Mm Dia Nominal Bore. Dsr-18.38.1 15.00 Rm. 14.55 13.97 209.51 B) 25Mm Dia Nominal Bore. Dsr-18.38.3 10.00 Rm. 22.69 21.78 217.79 2 Providing And Fixing 45 Cm Long Unplasticised Pvc Connection Pipe With Brass Unions. A) 15Mm Nominal Bore Dsr18.21.2.1 4.00 Nos. 73.31 70.38 281.51 5 Providing & Fixing Cp Brass Bib Cock Of Approved Quality Conforming To Is 8931 A) 15Mm Nominal Bore 18.49.1 7.00 Nos. 380.09 364.88 2554.19 6 Providing & Fixing C.P. Brass Long Body Bib Cock Of Approved Quality Conforming To Is Standards And Weighing Not Less Than 690 Gms. A) 15Mm Nominal Bore 18.51.1 7.00 Nos. 599.19 575.22 4026.57 7 Providing & Fixing C.P. Brass Angle Valve For Basin Mixer And Gyser Points Of Approved Quality Conforming To Is 8931 A) 15Mm Nominal Bore 18.53.1 14.00 Nos. 430.71 413.48 5788.75 8 Providing And Fixing Gun Metal Gate Valve With Wheel Of Approved Quality. A) 25Mm Dia Nominal Bore 18.17.1 2.00 Each 466.78 448.11 896.23 B) 32Mm Dia Nominal Bore 18.17.2 1.00 Each 517.18 496.50 496.50 C) 50Mm Dia Nominal Bore 18.17.4 Each 769.96 739.16 Water Supply Pipes And Fittings - Iii 9 Providing And Fixing Ball Valve (Brass) Of Approved Quality, High Or Low Pressure, With Plastic Floats Complete 20Mm Dia Nominal Bore 18.18.2 1.00 Each 346.86 332.99 332.99 A) 25 Mm Nominal Bore 18.18.3 2.00 Nos. 348.03 334.10 668.21 10 Providing And Placing On Terrace (At All Floor Levels) Polyethylene Water Storage Tank Of Approved Brand And Manufacture With Cover And Suitable Locking Arrangement And Making Necessary Holes For Inlet, Outlet And Overflow Pipes But Without Fittings And The Base Support For Tank. 18.48 A) Circular Tank 18.48 2500.00 Ltrs 8.25 7.92 19799.33 11 Providing And Fixing Stone Slab Table Rubbed, Edges Rounded And Polished Of Size 75X50Cm Deep And 1.8Cm Thick Fixed In Urinal Partitions By Cutting A Chase Of Appropriate Width With Chase Cutter And Embedding The Stone In The Chase With Epoxy Grout Or With Cement Concrete 1:2:4 (1Cement: 2Coarse Sand: 4Graded Stone Aggregate 6Mm Nominal Size) As Per Direction Of Engineerin-Charge And Finished Smooth. 8.10 Granite Stone Of Approved Shade Dsr-8.10.2 1.08 Sqm. 3038.79 2917.23 3150.61 1 Providing & Fixing Soil, Waste And Vent Pipes. A) 100Mm Dia Centrifugally Cast Iron S & S Pipe. Dsr17.35.1.2 6.00 Rm. 885.53 850.11 5100.67 2 Providing Lead Caulked Joints To Sand Cast Iron/Centrifugally Cast (Spun) Iron Pipes & Fitting Of Diameters. A) 100Mm Dsr-17.58.1 2.00 Each 466.86 448.18 896.37 3 Providing & Fixing M.S. Holder Bat Clamps Of Approved Design To Sand Cast Iron/Centrifugally Cast (Spun) Iron S & S Pipe Embeded In & Including Cement Concrete Blocks 10X10X10Cm. Of 1:2:4 Mix (1 Cement : 2 Coarse : 4 Graded Stone Aggregate 20Mm Nominal Size). Including Cost Of Cutting Holes & Making Good The Walls Etc. A) For 100Mm Dia Pipe. Dsr-17.37.1 2.00 Each 272.13 261.24 522.49 4 Providing & Fixing Cast Iron Trap Of Self Cleansing Design With Or Without Ventarm Complete, Including Cost Of Cutting & Making Good The Walls & Floors. A) 100Mm Inlet & 75Mm Outlet. Dsr17.60.2.1 1.00 No. 1481.31 1422.06 1422.06 5 Providing & Fixing Cast Iron Coller. A) 100Mm Dia. Dsr17.57.1.2 2.00 No. 384.85 369.46 738.91 6 Providing And Fixing Plain Cast Iron S & S Sanitary Bend. A) 100Mm Dsr17.39.1.2 2.00 Nos. 427.52 410.42 820.84 1 Providing And Fixing In Floor And Wall Face Ringfit Upvc Astral Ultradrain Conventional System For Soil And Waste Water Pipes Conforming To (Hsn Code: 3917) Type B Including Jointing With Seal Ring. (I) Double Socketed Pipes. A) 110Mm Dia P.V.C. Pipe Mr 7.50 M 485.00 465.60 3492.00 2 Providing And Fixing Square Mouth S.W. Gully Trap Grade A Complete With C.I. Grating Brick Masonry Chamber With F.P.S. Bricks Of Class Designation 75 And Water Tight C.I. Cover With Frame Of 300 X 300Mm. Size (Inside) The Weight Of Cover To Be Not Less Than 4.50 Kg And Frame To Be Not Less Than 2.70 Kg As Per Standard Design. A) 150 X 100 Mm. Size P Type With Sewer Bricks Conforming To Is : 4885 Dsr-19.4.2.1 1.00 Nos 2050.58 1968.56 1968.56 Soil Waste & Vent Pipes And Fittings - Ii Schedule Of Quantities For Internal Sewerage System - Iv 3 Constructing Brick Masonry Manhole In Cement Mortar 1:4 (1 Cement :4 Coarse Sand) Rcc Top Slab With 1:2:4 Mix (1 Cement :2 Coarse Sand :4 Graded Stone Aggregate 20Mm Nominal Size), Foundation Concrete 1:4:8 Mix (1 Cement :4 Coarse Sand :8 Graded Stone Aggregate 40Mm Nominal Size) Inside Plastering 12Mm Thick With Cement Mortar 1:3 (1 Cement :3 Coarse Sand) Finished With Floating Coat Fo Neat Cement And Making Channels In Cement Concrete 1:2:4 (1 Cement :2 Coarse Sand :4 Graded Stone Aggregate 20Mm Nminal Size) Finished With A Floating Coat Of Neat Cement Complete As Per Standard Design 19.7 Inside Size 90X80Cms And 45Cms Deep Including Ci Cover With Frame (Light Duty) 455X610Mm Internal Diamensions Total Weight Of Cover And Frame To Be Not Less Than 38 Kg (Weight Of Cover 23 Kg And Weight Of Frame 15Kg). 19.7.1 With Fps Bricks Of Class Designation 150 Dsr-19.7.1.1 1.00 Each 9577.59 9194.49 9194.49 External Sewerage Works 1 Excavating Trenches In All Kind Of Soil Of Required Width For Pipes. Including Excavation For Sockets And Dressing Of Sides, Ramming Of Bottoms, Including Getting Out The Excavated Soil & Then Returning The Soil As Required, In Layers Not Exceeding 20 Cm In Depth Including Consolidating Each Deposited Layer By Ramming, Watering, Etc & Disposing Of Surplus Excavated Soil As Directed Within A Lead Of 50M. Up To 1.50 M Depth Pipes 80 Mm To 300 Mm Diameter 2.10.1.2 20.00 Rm 264.10 253.54 5070.79 2 Providing And Fixing In Floor And Wall Face Ringfit Upvc Astral Ultradrain Conventional System For Soil And Waste Water Pipes Conforming To (Hsn Code: 3917) Type B Including Jointing With Seal Ring. (I) Double Socketed Pipes. 160Mm Dia Under Floor (For External Sewer) Nsr 20.00 Metre 1190.00 1142.40 22848.00 3 Constructing Brick Masonry Manhole With F.P.S. Bricks In Cement Mortar 1 : 4 (1 Cement : 4 Coarse Sand) Rcc Top Slab With 1 : 2 : 4 Mix (1 Cement : 2 Coarse Sand : 4 Grade Stone Aggregate 20Mm Nominal Size); Foundation Concrete 1:4:8 Mix (1 Cement : 4 Coarse Sand : 8 Graded Stone Aggregate 40 Mm Nominal Size) Inside Plastering 12 Mm Thick With Cement Mortar 1:3 (1Cement 3 Coarse Sand) Finished With A Floating Coat Of Neat Cement And Making Channels In Cement Concrete 1:2:4 (1Cement : 2 Coarse Sand: 4 Graded Stone Aggregate 20 Mm Nominal Size) Finishd With A Floating Coat Of Neat Cement Complete As Per Standard Design Inside Size 90 X 80 Cm & 45 Cm Deep Including Ci Cover With Frame (Light Duty) 455 X 610 Mm Internal Dimension Total Wt. Of Cover & Frame To Be Not Less Than 38 Kg (Wt. Of Cover 23 Kg And Wt. Of Frame 15 Kg) 19.7.1.1 3.00 Nos 9577.59 9194.49 27583.46 4 Extra For Depth For Manhole With F.P.S. Bricks Size 90 X 80 Cm 19.8.1.1 0.30 Rm 6618.83 6354.07 1906.22 5 Providing M.S. Foot Rests Including Fixing In Manholes With 20*20*10 Cm Cement Concrete Blocks 1:3:6 (1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20 Mm Nominal Size) As Per Standard Design : With 20 X 20 Mm Square Bar 19.15.1 3.00 Nos 408.51 392.17 1176.51 6 Providing And Fixing Square Mouth S.W. Gully Trap Grade `A Complete With C.I. Grating Brick Masonry Chamber With F.P.S Bricks And Water Tight Ci Cover With Frame Of 300 X 300 Mm Size (Inside) The Weight Of Cover To Be Not Less Than 4.50 Kg And Frame To Be Not Less Than 2.70 Kg As Per Standard Design 180 X 150 Mm. Size P Type 19.4.3.1 2.00 Nos 2101.54 2017.48 4034.96 7 Making Soak Pit 2.5 M Diameter 3.0 Metre Deep With 45 X 45 Cm Dry Brick Honey Comb Shaft With Bricks And S.W. Drain Pipe 100 Mm Diameter, 1.8 M Long Complete As Per Standard Design. With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 19.32.1 1.00 Nos 20145.75 19339.92 19339.92 8 Providing M.S. Foot Rests Including Fixing In Manholes With 20X20X10 Cm Cement Concrete Blocks 1:3:6 (1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20 Mm Nominal Size) As Per Standard Design With 20X20 Mm Square Bar Dsr-19.15.1 8.00 Nos. 408.51 392.17 3137.37 9 Providing And Fixing S.C.I. Tee 150 Mm At The Inlet And Outlet Of Septic Tank. Dsr-7087 2.00 Nos. 621.00 596.16 1192.32 10 Providing And Fixing Soil, Waste And Vent Pipes:75 Mm Diameter Sand Cast Iron S&S Pipe As Per Is: 1729 Dsr17.35.2.1 3.00 Rmt. 783.54 752.19 2256.58 11 Providing & Fixing Of 75Mm Dia Sand Cast Iron S&S As Per Is - 1729 Terminal Guard. Dsr17.56.2.1 2.00 Nos. 255.52 245.30 490.59 12 Providing & Fixing 75Mm Plane Sand Cast Iron S&S Bend Of Required Drgtee. Dsr17.39.2.1 2.00 Nos. 282.18 270.89 541.78 13 Providing Lead Caulked Joints To Sand Cast Iron/ Cetrifugally Cast (Squn) Irons Pipes & Fitting Of 50 Mm Dia Dsr-17.58.2 2.00 Nos. 394.67 378.89 757.77 14 Providing And Fixing In Position Precast Rcc Manhole Cover And Frame Of Required Shape And Approved Quality.M.D. -10- Circular Shape 500Mm Internal Diameter Dsr19.19.2.2 2.00 Nos. 879.42 844.24 1688.49 1 Wiring For Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq.Mm Frls/Hffr Pvc Insulated Copper Conductor Single Core Cable In Surface/ Recessed Medium Class Pvc Conduit, With Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm Frls/Hffr Pvc Insulated Copper Conductor Single Core Cable Etc. As Required Dsr 1.10.3 51.00 Each 1115.37 1070.76 54608.68 2 Wiring For Twin Control Light Point With 1.5 Sq.Mm Frls/Hffr Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Medium Class Pvc Conduit, 2Way Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm Frls/Hffr Pvc Insulated Copper Conductor Single Core Cable Etc. As Required Dsr 1.11 4.00 Each 1187.60 1140.10 4560.39 3 Supplying And Fixing Of Following Sizes Of Medium Class Pvc Conduit Along With Accessories In Surface/Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. Dsr 1.21.1 17.00 Metre 97.32 93.43 1588.26 4 Wiring For Circuit/ Submain Wiring Along With Earth Wire With The Following Sizes Of Frls/Hffr Pvc Insulated Copper Conductor, Single Core Cable In Surface/ Recessed Medium Class Pvc Conduit As Required.2 X 1.5 Sq. Mm + 1 X 1.5 Sq. Mm Earth Wire Dsr 1.14.1 650.00 Metre 177.15 170.07 110542.86 5 Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface/ Recessed Medium Class Pvc Conduit As Required 2 X 2.5 Sq. Mm + 1 X 2.5 Sq. Mm Earth Wire Dsr 1.14.2 188.00 Metre 285.12 273.71 51457.72 6 Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface/ Recessed Medium Class Pvc Conduit As Required 2 X 4 Sq. Mm + 1 X 4 Sq. Mm Earth Wire Dsr 1.14.3 202.00 Metre 253.94 243.79 49244.67 7 Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface/ Recessed Medium Class Pvc Conduit As Required 2 X 6 Sq. Mm + 1 X 6 Sq. Mm Earth Wire Dsr 1.14.4 105.00 Metre 333.78 320.42 33644.59 8 Supplying And Fixing Suitable Size Gi Box With Modular Plate And Cover In Front On Surface Or In Recess, Including Providing And Fixing 6 Pin 5/6 & 15/16 A Modular Socket Outlet And 15/16 A Modular Switch, Connections Etc. As Required Dsr 1.32 22.00 Each 445.54 427.72 9409.83 9 Supplying And Fixing Brass Batten/ Angle Holder Including Connection Etc. As Required Dsr 1.34 15.00 Each 99.60 95.62 1434.25 Electrical Works 10 Installation ,Testing, Commissioning Of Wall Bracket /Ceiling Fittings Of All Sizes And Shapes Containing Upto Two Ls/Cfl/Led Lamps Per Fitting, Complete With All Accessories Including Connections Etc. As Required. Dsr 1.35 1.00 Each 90.48 86.86 86.86 11 Supplying, Installation, Testing & Commissioning Of Led Recessed/ Surface Down Lighter (Round/ Square/ Rectangular) Smd Type Of Following Body Material With Pmma And Prismatic Diffuser And Construction As Per Is : 10322 With Driver As Per The Requirement With Driver Efficiency >85%, Operating Voltage Ac 140-270 Volt, Frequency 50/60 Hz, Operating Temp Range -50C To 400C, Internal Surge Protection Of 2.5 Kv With Short & Open Circuit Protection ,Thd < 10% , P. F.≥0.95, Ip20, Cri >80, Ugr (Unified Glare Rating) < 19, Flicker Free (Flicker Should Be Below 5%), Life Time (Led, Driver & Electrical Circuitry), Of Minimum 50000 Burning Hours With 70% Of Initial Lumen Maintained Till Life Ends, Cct 3000°K /4000°K / 5700°K / 6500°K (As Per Ansi Bin), Sdcm (Standard Deviation Colour Matching) <3, Maximum Power Consumption Should Not More Than The Specified Rating And Fixture Shall Be Confirming To Relevant Bis Standards. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen Printing On Housing Complete In All Respect I/C External Connections With 1.5 Sq.Mm Frls/Hffr, Pvc Insulated Copper Conductor Single Core Cable And Earthing Etc. As Required With Minimum 5 Year Oem Warranty. System Lumen Efficacy ≥105 And <120 Lm/Watt Output . Lm79 & Lm80 Test Report And All Testing Required For Led Fixtures As Per Bis Shall Be Submitted. Shape Size And Cct Shall Be As Approved By Engineer-In-Charge As Per Requirement. (Thermal Management: Heat Sink Of Aluminium Housing Such That Led Junction Temperature Shall Not Rise Above 90°C) Powder Coated Die Cast /Extruded Aluminium Body Including Trim 18 Watt Mr 19.00 Each 700.00 672.00 12768.00 12 Earthing With G.I. Earth Plate 600 Mm X 600 Mm X 6 Mm Thick Including Accessories, And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Of 2.7 Metre Long Etc. With Charcoal/ Coke And Salt As Required Dsr-5.4 3.00 Each 5681.03 5453.79 16361.37 13 Supplying And Laying 25 Mm X 5 Mm G.I Strip At 0.50 Metre Below Ground As Strip Earth Electrode, Including Connection/ Terminating With G.I. Nut, Bolt, Spring, Washer Etc. As Required. (Jointing Shall Be Done By Overlapping And With 2 Sets Of G.I. Nut Bolt & Spring Washer Spaced At 50Mm) Dsr 5.9 55.00 Metre 109.48 105.11 5780.78 14 Supplying And Fixing 5 A To 32 A Rating, 240/415 V, 10 Ka, C Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. A) Single Pole Dsr-2.10.1 9.00 Each 194.64 186.85 1681.68 15 Supplying And Fixing Following Way, Single Pole And Neutral, Sheet Steel, Mcb Distribution Board, 240 V, On Surface/ Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Including Earthing Etc. As Required. (But Without Mcb/Rccb/Isolator) A) 6 Way (4 + 12), Double Door Dsr-2.3.1 2.00 Each 1677.24 1610.15 3220.30 16 Supplying And Fixing Following Way, Horizontal Type Three Pole And Neutral, Sheet Steel, Mcb Distribution Board, 415 V, On Surface/ Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Including Earthing Etc. As Required. (But Without Mcb/Rccb/Isolator) A) 4 Way (4 + 12), Double Door Dsr-2.4.1 1.00 Each 3110.42 2986.01 2986.01 17 Supplying And Fixing 5 A To 32 A Rating, 240/415 V, 10 Ka, C Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. Dsr-2.10.3 2.00 Each 498.76 478.81 957.62 16 Installation, Testing And Commissioning Of Ceiling Fan, Including Wiring The Down Rods Of Standard Length (Upto 30 Cm) With 1.5 Sq. Mm Frls Pvc Insulated, Copper Conductor, Single Core Cable, Including Providing And Fixing Phenolic Laminated Sheet Cover On The Fan Box Etc. As Required Dsr 1.45 10.00 Each 257.74 247.43 2474.35 17 Supplying And Fixing Two Module Stepped Type Electronic Fan Regulator On The Existing Modular Plate Switch Box Including Connections But Excluding Modular Plate Etc. As Required. Dsr 1.25 10.00 Each 280.55 269.33 2693.32 18 Installation Of Exhaust Fan In The Existing Opening, Including Making Good The Damage, Connection, Testing, Commissioning Etc. As Required. Upto 450 Mm Sweep Dsr-1.50.1 7.00 Each 342.14 328.45 2299.17 19 Extra For Fixing The Louvers/ Shutters Complete With Frame For A Exhaust Fan Of All Sizes Dsr-1.51 7.00 Each 157.38 151.09 1057.62 20 Supply, Installation, Testing And Commissioning Of Ceiling Fan With Brush Less Direct Current (Bldc) Motor, Class Of Insulation: B, 3 Nos. Metal( Aluminium Alloy) Blades, 30 Cm Long Down Rod, 2 Nos. Canopies, Shackle Kit, Safety Rope, Copper Winding, Steel/Al Body Power Factor Not Less Than 0.9, Service Value (Cm/M/W) Minimum As Below, 350 Rpm (Tolerance As Per Is : 374-2019), Thd (Total Harmonic Distortion) Less Than 10%, Suitable For Operation With Regulator For Speed Control And All Remaining Accessories Including Safety Pin, Nut Bolts, Washers, Temperature Rise=75 0C (Max.), Insulation Resistance More Than 2 Mega Ohm, Suitable For 230 V, 50 Hz, Single Phase Ac Supply, Ceiling Fan Compliant To Is 374:2019 Fan I/C External Connections With 1.5 Sq.Mm Frls/Hffr, Pvc Insulated Copper Conductor Single Core Cable And Earthing Etc. As Required. 9.2.3 10.00 Each 2075.64 1992.62 19926.18 21 Supplying And Laying Of Aluminium Conductor Pvc Insulated Armoured Served Sheathed Cable 1100 Volts Grade At The Depth Of 750 Mm Bellow Ground Level Over A Cushion Of 75 Mm Thick Sand All Around And Protected With Burnt Bricks On Side And On Top .On Surface The Cable Run Shall Be Fixed On Ms Clamps Etc.Of Suitable Size Or As Directed By The Engineer-Incharge ,Complete In All Respect.The Armouring Of The Cable Shall Be Properly Connected With The Earth Conductor By Clamps Etc. Following Size 10 Sqmm X 2 Core Mr 164.00 Rm 410.34 393.93 64603.77 22 Supply & Fixing Of 225/230Mm Sweep Ventilating (Light Duty) Exhaust Fan Complete With Metallic Blade (Steel Bird Guard Protector /Copper Motor For High Air Suction Performance /Capacitor Etc.), Noise Level : (45 - 50) Db, Power Consumption : 45 W, Rated Voltage : 230 V, Rated Frequency : 50 Hz, Motor Type : Normal Speed. Complete In All Respect. Mr 7.00 Each 1665.00 1598.40 11188.80 23 Cost For Murals Work 32.40 Sqm 5850.00 5616.00 181958.40 24 Cost For Solar Street Light With 7M Pole Complete 15.00 Nos 22600.00 21696.00 325440.00 25 Cost For C.C. Bench 12.00 Nos 10000.00 9600.00 115200.00 26 Cost For Dustbin 6.00 Nos 4500.00 4320.00 25920.00 1. Trenching In Ordinary Soil Up To A Depth Of 60 Cm Including Removal And Stacking Of Serviceable Materials And Then Disposing Of Surplus Soil, By Spreading And Neatly Levelling Within A Lead Of 50 M And Making Up The Trenched Area To Proper Levels By Filling With Earth Or Earth Mixed With Sludge Or / And Manure Before And After Flooding Trench With Water (Excluding Cost Of Imported Earth, Sludge Or Manure).. (Horti) 2.1 159.24 Cum 74.51 71.53 11389.98 2 Supplying And Stacking Of Good Earth At Site Including Royalty And Carriage Upto 5 Km Lead Complete (Earth Measured In Stacks Will Be Reduced By 20% For Payment). (Horti) 2.2 79.62 Cum 491.88 472.21 37597.13 Horticulture 3 Supplying And Stacking At Site Dump Manure From Approved Source, Including Carriage Upto 5 Km Lead Complete (Manure Measured In Stacks Will Be Reduced By 8% For Payment) : Screened Through Sieve Of I.S. Designation 20 Mm (Horti) 2.4.1 106.16 Cum 242.46 232.76 24709.88 4 Spreading Of Sludge, Dump Manure And / Or Good Earth In Required Thickness As Per Direction Of Officer-In-Charge (Cost Of Sludge, Dump Manure And / Or Good Earth To Be Paid Separately). (Horti) 2.8 159.24 Cum 49.94 47.94 7634.64 5 Mixing Earth And Sludge Or Manure In The Required Proportion Specified Or Directed By The Officer-In-Charge (Horti) 2.9 159.24 Cum 34.87 33.47 5330.39 6 Grassing With Selection No.1 Grass Including Watering And Maintenance Of The Lawn For 30 Days Or More Till The Grass Forms A Thick Lawn, Free From Weeds And Fit For Mowing Including Supplying Good Earth, If Needed (The Good Earth Shall Be Paid For Separately). In Rows 5 Cm Apart In Both Directions. (Horti) 2.10.1 530.80 Sqm 16.89 16.21 8604.46 7 Providing And Displaying Of Aglaonema Silver Queen Having 30 Cm To 45 Cm. Ht. With 12 To 15 Leaves, Multi Suckers, Fresh And Healthy Leaves, Well Developed In 25 Cm Dia Earthen Pot/Plastic Pot & As Per Direction Of The Officer-In-Charge. (Horti) 3.8 60.00 Each 154.50 148.32 8899.22 (Horti) Dsr 3.8 8 Providing And Displaying Of Aglaonema Dove Variety Having Ht. 30 Cm To 45 Cm With 8 To 10 Leaves, Well Developed, Fresh And Healthy In 25 Cm Size Of Earthen Pot/Plastic Pot & As Per Direction Of The Officer-In-Charge. (Horti) 3.4 75.00 Each 77.42 74.32 5574.03 (Horti) Dsr 3.4 9 Providing And Displaying Of Aglaonema Marentifolium Variety Having Ht. 23 Cm To 30 Cm With 8 To 10 Leaves, Well Developed, Fresh And Healthy With Colorful Leaves In 20 Cm Size Of Earthen Pot/Plastic Pot. & As Per Direction Of The Officer-In-Charge. (Horti) 3.10 50.00 Each 64.54 61.96 3097.83 (Horti) Dsr 3.10 10 Providing And Displaying Of Chamaedorea Elegans Palm Having Ht. 60 Cm To 75 Cm, Well Developed With Fresh And Healthy Leaves In 25 Cm Size Of Earthen Pot/Plastic Pot. & As Per Direction Of The Officer-In-Charge. (Horti) 3.26 50.00 Each 102.70 98.59 4929.51 (Horti) Dsr 3.26 11 Providing And Displaying Of Croton Baby Golden Variety Having Ht.30 Cm And Above, Well Developed With Full Of Fresh And Healthy Leaves In 20 Cm Size Of Earthen Pot/Plastic Pot & As Per Direction Of The Officer-In-Charge. (Horti) 3.28 150.00 Each 39.11 37.55 5632.42 (Horti) Dsr 3.28 12 Providing And Displaying Of Croton Golden (Broad Leaves) Having Ht. 60 Cm To 75 Cm With 3 To 4 Branches, Well Developed, Fresh And Healthy Leaves In 25 Cm Size Of Earthen Pot/Plastic Pot. & As Per Direction Of The Officer-In-Charge. (Horti) 3.32 150.00 Each 53.81 51.65 7748.01 (Horti) Dsr 3.32 13 Providing And Displaying Of Dieffenbachia Tropic-Snow Having Ht. 60 Cm & Above With 8 - 10 Leaves, Well Developed, Fresh & Healthy In 25 Cm Size Of Earthen Pot/Plastic Pot & As Per Direction Of The Officer-In-Charge. (Horti) 3.40 50.00 Each 75.32 72.31 3615.28 (Horti) Dsr 3.40 14 Providing And Displaying Of Dieffenbachia Mosaic Having Ht. 30Cm To 45 Cm With 10-12 Leaves, Well Developed, Fresh And Healthy In 25 Cm Size Of Earthen Pot/Plastic Pot. & As Per Direction Of The Officer-In-Charge. (Horti) 3.41 50.00 Each 75.32 72.31 3615.28 (Horti) Dsr 3.41 15 Providing And Displaying Dianthus In Different Colour Well Developed With Fresh & Healthy Foliage 30 Cm Ht., In Full Bloom With Stacking In 25 Cm Earthen Pot/Plastic Pot And As Per Direction Of The Officer-In-Charge. (Horti) 4.29 50.00 Each 51.79 49.72 2486.05 (Horti) Dsr 4.29 16 Providing And Displaying Gazania Hybrid In Different Colour Well Developed With Fresh & Healthy Foliage With Full Bloom In 25 Cm Earthen Pot/Plastic Pot And As Per Direction Of The Officer-Incharge. (Horti) 4.31 150.00 Each 61.63 59.16 8874.49 (Horti) Dsr 4.31 17 Providing And Displaying Gaillardia Double Hybrid Variety Well Developed 30 To 45 Cm Ht 20 To 30 Fresh & Healthy Flower With Green Painted Bamboo Stick In 25 Cm Earthen Pot/Plastic Pot And As Per Direction Of The Officer-In-Charge. (Horti) 4.75 120.00 Each 51.85 49.78 5973.11 (Horti) Dsr 4.75 18 Providing And Stacking Of Plant Mogra Of Height 25 To 30 Cm., 2 To 3 Branch In Earthen Pots Of Size 20 Cm Earthen Pot/Plastic Pot And As Per Direction Of The Officer-In-Charge. (Horti) 4.88 100.00 Each 44.03 42.27 4226.60 (Horti) Dsr 4.88 19 Providing And Stacking Of Plant Canna Dwarf Of Height 25 To 30 Cm., 2 To 3 Suckers In Earthen Pots Of Size 20 Cm Earthen Pot/Plastic Pot And As Per Direction Of The Officer-In-Charge. (Horti) 4.89 100.00 Each 34.25 32.88 3287.87 (Horti) Dsr 4.89 20 Bush Rose In Different Colour 2 To 3 Healthy Branch 30 Cm And Above Ht. Well Developed With 8 Or More Flowers / Flower Buds In 20 Cm Earthen Pot /Plastic Pot As Per Direction Of The Officer-Incharge. (Horti) 4.90 100.00 Each 24.47 23.49 2349.13 (Horti) Dsr 4.90 21 Providing And Displaying Budded Rose (H.T. Variety) 3 To 4 Healthy Branch 30 Cm And Above Ht. Well Developed With One And Above Flower Plant In 20 Cm Earthen Pot, As Per Direction Of The Officer-In-Charge. (Horti) 4.91 100.00 Each 31.29 30.04 3003.96 (Horti) Dsr 4.91 22 Providing And Displaying Standard Rose (H.T. Variety) 3 To 4 Healthy Branch 90 Cm And Above Ht. Well Developed With One And Above Flowers In 25 Cm Earthen Pot, As Per Direction Of The Officer-In-Charge. (Horti) 4.93 75.00 Each 143.77 138.02 10351.28 (Horti) Dsr 4.93 23 Providing And Stacking Of Plumeria Rubra Of Height 120-150 Cm. With 3-4 Branches And Thick Stem In Big Size Hdpe Bags As Per Direction Of The Officer-In-Charge. (Horti) 7.72 75.00 Each 381.60 366.34 27475.20 (Horti) Dsr 7.72 24 Providing And Stacking Of Polyalthia Longifolia (Ashok) Of Height 180-195 Cm. In Gunny Bag Of Size 30 Cm As Per Direction Of The Officer-Incharge. (Horti) 7.75 75.00 Each 95.40 91.58 6868.80 (Horti) Dsr 7.75 25 Providing And Stacking Of Saraca Indica (Sita Ashok) Of Height 105-120 Cm. In Big Poly Bags Of Size 25 Cm As Per Direction Of The Officer-In-Charge. (Horti) 7.80 75.00 Each 76.32 73.27 5495.04 (Horti) Dsr 7.80 26 Providing And Stacking Of Terminalia Arjuna Of Height 150-165 Cm. In Big Polybags Of Size 25 Cm As Per Direction Of The Officerin-Charge. (Horti) 7.88 75.00 Each 57.24 54.95 4121.28 (Horti) Dsr 7.88 27 Providing And Stacking Of Calliandra, Emarginata Of Height 45-60 Cm. In Earthen Pot Of Size 20 Cm As Per Direction Of The Officer-Incharge. (Horti) 8.5 150.00 Each 33.39 32.05 4808.16 (Horti) Dsr 8.5 28 Providing And Stacking Of Nerium Oleander (Kaner) Of Height 60- 75 Cm. With 5-6 Branches In Poly Bags Of Size 25 Cm As Per Direction Of The Officer-In-Charge.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
Uttar Pradesh View Result →
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 4
Jammu And Kashmir View Result →
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 4
Himachal Pradesh View Result →
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 4
Himachal Pradesh View Result →
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Himachal Pradesh View Result →
20.
Educational and Research Institute #11307517 Technical Bid
Tender For Ambedkar Gramam Project For Sc Unnathy Pookkunnimala- 1 1) Anganwadi-Civil Works-Ground Floor 2 15.9.2 Demolishing Stone Rubble Masonry Manually / By Mechanical Means Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Metres Lead As Per Direction Of Engineer -In- Charges:In Cement Mortar 3 15.7.4 Demolishing Brick Work Manually / By Mechanical Means Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Metres Lead As Per Direction Of Engineer-In-Charge.In Cement Mortar 4 15.2.2 Demolishing Cement Concrete Manually / By Mechanical Means Including Disposal Of Material Within 50 Metres Lead As Per Direction Of Engineer - In-Charge.Nominal Concrete 1:4:8 Or Leaner Mix ( Including Equivalent Design Mix) 5 15.19 Dismantling Steel Work Manually / By Mechanical Means In Built Up Sections Without Dismembering And Stacking Within 50 Metres Lead As Per Directions Of Engineer -In- Charge. 6 15.28.1 Dismantling Roofing Including Ridges, Hips, Velleys And Gutters Etc., And Stacking The Material Within 50 Metres Lead Of :G.S. Sheet 7 15.13.1 Taking Out Doors, Windows And Clerestory Window Shutters (Steel Or Wood ) Including Stacking Within 50 Metres Lead:Of Area 3 Sq. Metres And Below 8 2.6.1 Earth Work In Excavation By Mechanical Means (Hydraulic Excavator)/Manual Means Over Areas (Exceeding 30 Cm In Depth, 1.5 M In Width As Well As 10 Sqm On Plan) Including Getting Out And Disposal Of Excavated Earth Lead Upto 50 M And Lift Upto 1.5 M, As Directed By Engineer-In-Charge.All Kinds Of Soil 9 4.1.8 Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level:1:4:8 (1 Cement : 4 Coarse Sand (Zone-Iii) Derived From Natural Sources : 8 Graded Stone Aggregate 40 Mm Nominal Size Derived From Natural Sources) 10 5.9.1 Centering And Shuttering Including Strutting, Etc. And Removal Of Form For:Foundations, Footings, Bases Of Columns, Etc For Mass Concrete 11 5.9.5 Centering And Shuttering Including Strutting, Etc. And Removal Of Form For:Lintels, Beams, Plinth Beams, Girders Bressumers And Cantilevers 12 5.9.6 Centering And Shuttering Including Strutting, Etc. And Removal Of Form For:Columns, Pillars, Piers, Abutments, Posts And Struts 13 5.1.2 Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement - All Work Up To Plinth Level:1:1:5:3 (1 Cement 1.5 Coarse Sand :3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources) 14 5.2.2 Reinforced Cement Concrete Work In Walls (Any Thickness), Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc. Up Tot Floor Five Level Excluding Cost Of Centering, Shuttering, Finishing And Reinforcement :1:1.5:3( 1 Cement : 1.5 Coarse Sand : 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources) 15 5.9.3 Centering And Shuttering Including Strutting, Etc. And Removal Of Form For:Suspended Floors, Roofs, Landings, Balconies And Access Platform 16 5.3 Reinforced Cement Concrete Work In Beams, Suspended Floors, Roofs, Having Slope Up To 15° Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Window Sills, Staircases And Spiral Stair Cases Up To Floor Five Level Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement, With1:1.5:3 (1 Cement : 1.5 Coarse Sand (Zone Iii) Derived From Natural Sources: 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources). 17 5.22.6 Steel Reinforcement For R.C.C Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Upto Plinth Levelthermo - Mechanically Treated Bars Of Grade Fe-500D Or More 18 2.25 Filling Available Excavated Earth (Excluding Rock) In Trenches, Plinth, Sides Of Foundation Etc. In Layers Not Exceeding 20 Cm In Depth, Consolidating Each Deposited Layer By Ramming And Watering, Lead Up To 50 M And Lift Up To 1.5 M. 19 50.6.1.2 Solid Block Masonry Using Pre Cast Solid Blocks (Factory Made) Of Size 40X20X20Cm Or Nearest Available Size Confirming To Is 2185 Part I Of 1979 For Super Structure Up To Floor Two Level Thickness 20Cm And Above In: Cm 1:6 ( 1 Cement: 6 Coarse Sand) Etc Complete. 20 13.7.1 12 Mm Cement Plaster Finished With A Floating Coat Of Neat Cement Of Mix:1:3 ( 1 Cement : 3 Fine Sand) 21 13.1.1 12 Mm Cement Plaster Of Mix:1:4 ( 1 Cement : 4 Fine Sand) 22 50.9.1.1 Providing Wood Work In Frames Of Doors, Windows, Clerestory Windows And Other Frames, Wrought Framed And Fixed In Position With Hold Fast Lugs Or With Dash Fasteners Of Required Dia & Length (Hold Fast Lugs Or Dash Fastener Shall Be Paid For Separately), Using Good Quality Anjili Wood /Jack Wood 23 50.9.2.1 Providing And Fixing Paneled And Glazed Shutters For Doors, Windows And Clerestory Windows, 35 Mm Thick Shutters Including Isi Marked M.S. Pressed Butt Hinges Bright Finished Of Required Size With Necessary Screws, Excluding Panelling Which Will Bepaid For Separately, All Complete As Per Direction Of Engineerin - Charge Using Anjili/ Jack Wood 24 50.9.6.1 Providing And Fixing Glazed Shutters For Doors, Windows And Clerestory Windows Using 4 Mm Thick Float Glass Panes Including Isi Marked M.S. Pressed Butt Hinges Bright Finished Of Required Size With Necessary Screws. Using Anjili Wood / Jack Wood 30 Mm Thick Shutters 25 14.29 Providing And Fixing M.S. Round Or Squre Bars With M.S. Flats At Required Spacing In Wooden Frames Of Windows And Clerestory Windows. 26 10.27.5 Providing And Fixing Carbon Steel Galvanised ( Minimum Coating 5 Micron) Dash Fastener Of 10 Mm Dia Double Threaded 6.8 Grade (Yield Strength 480 N/Mm2), Counter Sunk Head, Comprising Of 10 M Dia Polyamide P A 6 Grade Sleeve, Including Drilling Of Hole In Frame, Concrete/Masonry, Etc. As Per Direction Of Engineer-In-Charge.10X 160 Mm 27 9.76 Providing And Fixing Bright Finished Brass 100 Mm Mortice Latch And Lock With 6 Levers And A Pair Of Lever Handles Of Approved Quality With Necessary Screws Etc. Complete. 28 9.92.1 Providing And Fixing Chromium Plated Brass Handles With Necessary Screws Etc. Complete:125 Mm 29 9.74.3 Providing And Fixing Bright Finished Brass Tower Bolts (Barrel Type) With Necessary Screws Etc. Complete:150X10 Mm 30 9.83 Providing And Fixing Aluminium Die Cast Body Tubular Type Universal Hydraulic Door Closer (Having Brand Logo With Isi, Is : 3564, Embossed On The Body, Door Weight Upto 35 Kg And Door Width Upto 700 Mm), With Necessary Accessories And Screws Etc. Complete. 31 Od123879/2025-2026 Providing And Fixing Frp (Fibre Reinforced Polymer) Door Shutter Of Size 90Cm And 28-30Mm Thickness With Frame 110Mm Thickness With Necessary Fittings Like Hinges, Cost Index (Place) : Kollam, Gst : 18% Printed On 2026-03-17 13:56:12.13 4 Including All Materials And Labour Charge Etc As Per The Direction Of Engineer In Charge 32 Od123885/2025-2026 Providing And Fixing Frp (Fibre Reinforced Polymer) Door Shutter Of Size 80Cm And 28-30Mm Thickness With Frame 110Mm Thickness With Necessary Fittings Like Hinges, Tower Bolts, Handles, Mortice/Cylindrical Locks And All Other Accessories Etc. Complete Including All Materials And Labour Charge Etc As Per The Direction Of Engineer In Charge 33 11.41.2 Providing And Laying Vitrified Floor Tiles In Different Sizes (Thickness To Be Specified By The Manufacturer) With Water Absorption Less Than 0.08% And Conforming To Is : 15622, Of Approved Make, In All Colours And Shades, Laid On 20 Mm Thick Cement Mortar 1:4(1 Cement : 4 Coarse Sand), Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete.Size Of Tile 600 X 600 Mm. 34 11.46.2 Providing And Laying Vitrified Tiles Indifferent Sizes (Thickness To Be Specified By Manufacturer), With Water Absorption Less Than 0.08 % And Conforming To I.S. 15622, Of Approved Make, In All Colours & Shade, In Skirting, Riser Of Steps, Over 12 Mm Thick Bed Of Cement Mortar 1:3 (1 Cement : 3 Coarse Sand), Including Grouting The Joint With White Cement & Matching Pigments Etc. Complete.Size Of Tile 600X600 Mm 35 11.37 Providing And Laying Ceramic Glazed Floor Tiles Of Size 300X300 Mm (Thickness To Be Specified By The Manufacturer) Of 1St Quality Conforming To Is : 15622 Of Approved Make In Colours Such As White, Ivory, Grey, Fume Red Brown, Laid On 20 Mm Thick Cement Mortar 1:4 (1 Cement : 4 Coarse Sand), Jointing With Grey Cement Slurry @ 3.3 Kg/Sqm Including Pointing The Joints With White Cement And Matching Pigment Etc., Complete 36 8.31 Providing And Fixing Ist Quality Ceramic Glazed Wall Tiles Conforming To Is: 15622 (Thickness To Be Specified By The Manufacturer), Of Approved Make, In All Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Engineer-In- Charge, In Skirting, Risers Of Steps And Dados, Over 12 Mm Thick Bed Of Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) And Jointing With Grey Cement Slurry @ 3.3Kg Per Sqm, Including Pointing In White Cement Mixed With Pigment Of Matching Shade Complete. 37 11.16.1 Precast Terrazo Tiles 22 Mm Thick With Graded Marble Chips Of Size Upto 12Mm, Laid In Floors, And Landings, Jointed With Neat Cement Slurry Mixed With Pigment To Match The Shade Of The Tiles Including Rubbing And Polishing Complete, On 20 Mm Thick Bed Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) :Light Shade Pigment Using White Cement 38 8.2.2.2 Providing And Fixing 18 Mm Thick Gang Saw Cut, Mirror, Polished, Premoulded And Prepolished, Machine Cut For Kitchen Platforms, Vanity Counters, Window Sills, Facias And Similar Locations, Of Required Size, Approved Shade, Colour And Texture Laid Over 20 Mm Thick Base Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand), Joints Treated With White Cement, Mixed With Matching Pigment, Epoxy Touch Ups, Including Rubbing, Curing, Moulding And Polishing To Edges To Give High Gloss Finish Etc. Complete At All Levels.Area Of Slab Over 0.50 Sqm 39 8.3.2 Providing Edge Moulding To 18 Mm Thick Marble Stone Counters, Vanities Etc., Including Machine Polishing To Edge To Give High Gloss Finish Etc. Complete As Per Design Approved By Engineer -In-Charge.Granite Work 40 13.80 Providing And Applying White Cement Based Putty Of Average Thickness 1 Mm, Of Approved Brand And Manufacturer, Over The Plastered Wall Surface To Prepare The Surface Even And Smooth Complete. 41 13.43.1 Applying One Coat Of Water Thinnable Cement Primer Of Approved Brand And Manufacture On Wall Surface:Water Thinnable Cement Primer 42 13.60.1 Wall Painting With Acrylic Emulsion Paint Of Approved Brand And Manufacture To Give An Even Shade:Two Or More Coats On New Work 43 13.47.1 Finishing Walls With Premium Acrylic Smooth Exterior Paint With Silicone Additives Of Required Shade:New Work (Two Or More Coats Applied @ 1.43 Ltr/ 10 Sqm Over And Including Priming Coat Of Exterior Primer Applied @ 2.20 Kg/ 10 Sqm) 44 13.85.1 Applying Priming Coats With Primer Of Approved Brand And Manufacture, Having Low Voc ( Volatile Organic Compound) Content.With Ready Mixed Pink Or Grey Primer On Wood Work (Hard And Soft Wood ) Having Voc Content Less Than 50 Grams/ Litre 45 13.61.1 Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture To Give An Even Shade:Two Or More Coats On New Work 46 10.28 Providing And Fixing Stainless Steel (Grade 304) Railing Made Of Hollow Tubes, Channels, Plates Etc., Including Welding, Grinding, Buffing, Polishing And Making Curvature (Wherever Required) And Fitting The Same With Necessary Stainless Steel Nuts And Bolts Complete, I/C Fixing The Railing With Necessary Accessories & Stainless Steel Dash Fasteners, Stainless Steel Bolts Etc., Of Required Size On The Top Of The Floor Or The Side Of Waist Slab With Suitable Arrangement As Per Approval Of Engineer-In-Charge, (For Payment Purpose Only Weight Of Stainless Steel Members Shall Be Considered Excluding Fixing Accessories Such As Nuts, Bolts, Fasteners Etc.) 47 Od134882/2025-2026 Supplying And Fixing Anganwadi/Library/Vignjaanwadi Name Board With Emblem Using Acrylic Sheet Base With Reflective Type Sticker As Per Required Shade And Color Etc Complete. Size Of Board 3.00Mx 0.60M 48 Od134893/2025-2026 Providing And Fixing Anganwadi/Library/Vignjaanwadi -Foundation Stone/Inauguration Stone Using Granite Of Size 70.00X135.00 Cm ,18Mm Thick With Writing Letters In Golden Colour Including Of All Material And Labour Charges Etc. Complete As Per The Directions Of Engineer-In-Charge. 49 2.1.1 Earth Work In Surface Excavation Not Exceeding 30 Cm In Depth But Exceeding 1.5M In Width As Well As 10 Sqm On Plan Including Disposal Of Excavated Earth Up To 50 M And Lift Up To 1.5 M, Disposed Soil To Be Levelled And Neatly Dressed:All Kinds Of Soil 50 16.68 Providing And Laying 60 Mm Thick Factory Made Cement Concrete Interlocking Paver Block Of M - 30 Grade Made By Block Making Machine With Strong Vibratory Compaction, Of Approved Size, Design & Shape, Laid In Required Colour And Pattern Over And Including 50 Mm Thick Compacted Bed Of Coarse Sand, Filling The Joints With Fine Sand Etc. All Complete As Per The Direction Of Engineer-In-Charge. 51 50.10.1 Steel Work In Built Up G I Tubular ( Round, Square Or Rectangular Hollow Tubes Etc.) Trusses Etc., Including Cutting, Hoisting,Fixing In Position And Applying A Priming Coat Of Approved Steel Primer, Including Welding And Bolted With Special Shaped Washers Etc. Complete 52 50.10.2 Steel Work For Purlin/Single Section With G I Pipes Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer, Including Welding And Bolted With Special Shaped Washers Etc. Complete 53 12.50 Providing And Fixing Precoated Galvanised Iron Profile Sheets (Size, Shape And Pitch Of Corrugation As Approved By Engineer-In-Charge) 0.50 Mm (+0.05%), Total Coated Thickness With Zinc Coating 120 Grams Per Sqm As Per Is: 277, In 240 Mpa Steel Grade, 5-7 Microns Epoxy Primer On Both Side Of The Sheet And Polyester Top Coat 15-18 Microns. Sheet Should Have Protective Guard Film Of 25 Microns Minimum To Avoid Scratches During Transportation And Should Be Supplied In Single Length Upto 12 Metre Or As Desired By Engineer-In-Charge. The Sheet Shall Be Fixed Using Self Drilling/Self Tapping Screws Of Size (5.5X55Mm) With Epdm Seal, Complete Upto Any Pitch In Horizontal/ Vertical Or Curved Surfaces, Excluding The Cost Of Purlins, Rafters And Trusses And Including Cutting To Size And Shape Wherever Required. 54 12.51.1 Providing And Fixing Precoated Galvanised Steel Sheet Roofing Accessories 0.50 Mm (+0.05 %) Total Coated Thickness, Zinc Coating 120 Grams Per Sqm As Per Is: 277, In 240 Mpa Steel Grade, 5-7 Microns Epoxy Primer On Both Side Of The Sheet And Polyester Top Coat 15-18 Microns Using Self Drilling/ Self Tapping Screwscomplete :Ridges Plain (500-600 Mm) 55 Od141946/2025-2026 Providing And Fixing 8 Upvc Aqua Pathy ( Gutter) With M.S Clamp All Complete As Per Direction Of Engineer-In-Charge. 56 1)Vignjaanwadi,Library Cum Reading Room-First Floor 57 5.9.6 Centering And Shuttering Including Strutting, Etc. And Removal Of Form For:Columns, Pillars, Piers, Abutments, Posts And Struts 58 5.9.5 Centering And Shuttering Including Strutting, Etc. And Removal Of Form For:Lintels, Beams, Plinth Beams, Girders Bressumers And Cantilevers 59 5.2.2 Reinforced Cement Concrete Work In Walls (Any Thickness), Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc. Up Tot Floor Five Level Excluding Cost Of Centering, Shuttering, Finishing And Reinforcement :1:1.5:3( 1 Cement : 1.5 Coarse Sand : 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources) 60 5.9.3 Centering And Shuttering Including Strutting, Etc. And Removal Of Form For:Suspended Floors, Roofs, Landings, Balconies And Access Platform 61 5.3 Reinforced Cement Concrete Work In Beams, Suspended Floors, Roofs, Having Slope Up To 15° Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Window Sills, Staircases And Spiral Stair Cases Up To Floor Five Level Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement, With1:1.5:3 (1 Cement : 1.5 Coarse Sand (Zone Iii) Derived From Natural Sources: 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources). 62 5.22.6 Steel Reinforcement For R.C.C Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Upto Plinth Levelthermo - Mechanically Treated Bars Of Grade Fe-500D Or More 63 50.6.1.2 Solid Block Masonry Using Pre Cast Solid Blocks (Factory Made) Of Size 40X20X20Cm Or Nearest Available Size Confirming To Is 2185 Part I Of 1979 For Super Structure Up To Floor Two Level Thickness 20Cm And Above In: Cm 1:6 ( 1 Cement: 6 Coarse Sand) Etc Complete. 64 13.7.1 12 Mm Cement Plaster Finished With A Floating Coat Of Neat Cement Of Mix:1:3 ( 1 Cement : 3 Fine Sand) 65 13.1.1 12 Mm Cement Plaster Of Mix:1:4 ( 1 Cement : 4 Fine Sand) 66 13.4.1 12 Mm Cement Plaster Of Mix:1:4 ( 1 Cement : 4 Coarse Sand) 67 50.9.1.1 Providing Wood Work In Frames Of Doors, Windows, Clerestory Windows And Other Frames, Wrought Framed And Fixed In Position With Hold Fast Lugs Or With Dash Fasteners Of Required Dia & Length (Hold Fast Lugs Or Dash Fastener Shall Be Paid For Separately), Using Good Quality Anjili Wood /Jack Wood 68 50.9.2.1 Providing And Fixing Paneled And Glazed Shutters For Doors, Windows And Clerestory Windows, 35 Mm Thick Shutters Including Isi Marked M.S. Pressed Butt Hinges Bright Cost Index (Place) : Kollam, Gst : 18% Printed On 2026-03-17 13:56:12.13 9 Paid For Separately, All Complete As Per Direction Of Engineerin - Charge Using Anjili/ Jack Wood 69 50.9.6.1 Providing And Fixing Glazed Shutters For Doors, Windows And Clerestory Windows Using 4 Mm Thick Float Glass Panes Including Isi Marked M.S. Pressed Butt Hinges Bright Finished Of Required Size With Necessary Screws. Using Anjili Wood / Jack Wood 30 Mm Thick Shutters 70 14.29 Providing And Fixing M.S. Round Or Squre Bars With M.S. Flats At Required Spacing In Wooden Frames Of Windows And Clerestory Windows. 71 10.27.5 Providing And Fixing Carbon Steel Galvanised ( Minimum Coating 5 Micron) Dash Fastener Of 10 Mm Dia Double Threaded 6.8 Grade (Yield Strength 480 N/Mm2), Counter Sunk Head, Comprising Of 10 M Dia Polyamide P A 6 Grade Sleeve, Including Drilling Of Hole In Frame, Concrete/Masonry, Etc. As Per Direction Of Engineer-In-Charge.10X 160 Mm 72 9.76 Providing And Fixing Bright Finished Brass 100 Mm Mortice Latch And Lock With 6 Levers And A Pair Of Lever Handles Of Approved Quality With Necessary Screws Etc. Complete. 73 9.92.1 Providing And Fixing Chromium Plated Brass Handles With Necessary Screws Etc. Complete:125 Mm 74 9.74.3 Providing And Fixing Bright Finished Brass Tower Bolts (Barrel Type) With Necessary Screws Etc. Complete:150X10 Mm 75 9.83 Providing And Fixing Aluminium Die Cast Body Tubular Type Universal Hydraulic Door Closer (Having Brand Logo With Isi, Is : 3564, Embossed On The Body, Door Weight Upto 35 Kg And Door Width Upto 700 Mm), With Necessary Accessories And Screws Etc. Complete. 76 Od127305/2025-2026 Providing And Fixing Frp (Fibre Reinforced Polymer) Door Shutter Of Size 80Cm 28-30Mm Thickness With Frame And Tower Bolts, Handles, Mortice/Cylindrical Locks And All Other Accessories Etc. Complete Including All Materials And Labour Charge Etc As Per The Direction Of Engineer In Charge 77 Od126510/2025-2026 Providing And Fixing Frp (Fibre Reinforced Polymer) Door Shutter Of Size 90Cm And 28-30Mm Thickness With Frame 110Mm Thickness With Necessary Fittings Like Hinges, Tower Bolts, Handles, Mortice/Cylindrical Locks And All Other Accessories Etc. Complete Including All Materials And Labour Charge Etc As Per The Direction Of Engineer In Charge 78 11.41.2 Providing And Laying Vitrified Floor Tiles In Different Sizes (Thickness To Be Specified By The Manufacturer) With Water Absorption Less Than 0.08% And Conforming To Is : 15622, Of Approved Make, In All Colours And Shades, Laid On 20 Mm Thick Cement Mortar 1:4(1 Cement : 4 Coarse Sand), Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete.Size Of Tile 600 X 600 Mm. 79 11.46.2 Providing And Laying Vitrified Tiles Indifferent Sizes (Thickness To Be Specified By Manufacturer), With Water Absorption Less Than 0.08 % And Conforming To I.S. 15622, Of Approved Make, In All Colours & Shade, In Skirting, Riser Of Steps, Over 12 Mm Thick Bed Of Cement Mortar 1:3 (1 Cement : 3 Coarse Sand), Including Grouting The Joint With White Cement & Matching Pigments Etc. Complete.Size Of Tile 600X600 Mm 80 11.37 Providing And Laying Ceramic Glazed Floor Tiles Of Size 300X300 Mm (Thickness To Be Specified By The Manufacturer) Of 1St Quality Conforming To Is : 15622 Of Approved Make In Colours Such As White, Ivory, Grey, Fume Red Brown, Laid On 20 Mm Thick Cement Mortar 1:4 (1 Cement : 4 Coarse Sand), Jointing With Grey Cement Slurry @ 3.3 Kg/Sqm Including Pointing The Joints With White Cement And Matching Pigment Etc., Complete 81 8.31 Providing And Fixing Ist Quality Ceramic Glazed Wall Tiles Conforming To Is: 15622 (Thickness To Be Specified By The Manufacturer), Of Approved Make, In All Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Engineer-In- Charge, In Skirting, Risers Of Steps And Dados, Over 12 Mm Thick Bed Of Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) And Jointing With Grey Cement Slurry @ 3.3Kg Per Sqm, Including Pointing In White Cement Mixed With Pigment Of Matching Shade Complete. 82 13.80 Providing And Applying White Cement Based Putty Of Average Thickness 1 Mm, Of Approved Brand And Manufacturer, Over The Plastered Wall Surface To Prepare The Surface Even And Smooth Complete. 83 13.43.1 Applying One Coat Of Water Thinnable Cement Primer Of Approved Brand And Manufacture On Wall Surface:Water Thinnable Cement Primer 84 13.60.1 Wall Painting With Acrylic Emulsion Paint Of Approved Brand And Manufacture To Give An Even Shade:Two Or More Coats On New Work 85 13.47.1 Finishing Walls With Premium Acrylic Smooth Exterior Paint With Silicone Additives Of Required Shade:New Work (Two Or More Coats Applied @ 1.43 Ltr/ 10 Sqm Over And Including Priming Coat Of Exterior Primer Applied @ 2.20 Kg/ 10 Sqm) 86 13.85.1 Applying Priming Coats With Primer Of Approved Brand And Manufacture, Having Low Voc ( Volatile Organic Compound) Content.With Ready Mixed Pink Or Grey Primer On Wood Work (Hard And Soft Wood ) Having Voc Content Less Than 50 Grams/ Litre 87 13.61.1 Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture To Give An Even Shade:Two Or More Coats On New Work 88 10.28 Providing And Fixing Stainless Steel (Grade 304) Railing Made Of Hollow Tubes, Channels, Plates Etc., Including Welding, Grinding, Buffing, Polishing And Making Curvature (Wherever Required) And Fitting The Same With Necessary Stainless Steel Nuts And Bolts Complete, I/C Fixing The Railing With Necessary Accessories & Stainless Steel Dash Fasteners, Stainless Steel Bolts Etc., Of Required Size On The Top Of The Floor Or The Side Of Waist Slab With Suitable Arrangement As Per Approval Of Engineer-In-Charge, (For Payment Purpose Only Weight Of Stainless Steel Members Shall Be Considered Excluding Fixing Accessories Such As Nuts, Bolts, Fasteners Etc.) 89 Od135395/2025-2026 Supplying And Fixing Anganwadi/Library/Vignjaanwadi Name Board With Emblem Using Acrylic Sheet Base With Reflective Type Sticker As Per Required Shade And Color Etc Complete. Size Of Board 3.00Mx 0.60M 90 1)Plumbing Works -Ground Floor & First Floor 91 17.3.2 Providing And Fixing White Vitreous China Pedestal Type Water Closet Bend With Fittings & C.I. Brackets, 40 Mm Flush Bend, Overflow Arrangement With Specials Of Standard Make And Mosquito Proof Coupling Of Approved Municipal Design Complete, Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls And Floors Wherever Required :W.C. Pan With Isi Marked Black Solid Plastic Seat And Lid 92 50.17.1.5 Supplying And Fixing Cp Health Faucet Superior Quality ( Jagur Or Equvalent Make ) Including Cost Of Materials And Labour Charges Etc Complete As Per The Direction Of Site Engineer-In-Charge. 93 17.7.2 Providing And Fixing Wash Basin With C.I. Brackets, 15 Mm C.P. Brass Pillar Taps, 32 Mm C.P. Brass Waste Of Standard Pattern, Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls Wherever Require:White Vitreous China Wash Basin Size 630 X 450 Mm With A Single 15 Mm C.P. Brass Pillar Tap 94 17.9.1 Providing And Fixing Kitchen Sink With C. I Brackets, C.P. Brass Chain With Rubber Plug, 40 Mm C.P Brass Waste Complete, Including Painting The Fittings And Brackets, Cutting And Making Good The Walls Wherever Required:White Glazed Fire Clay Kitchen Sink Of Size 600X450X250 Mm 95 18.53.1 Providing And Fixing C.P. Brass Angle Valve For Basin Mixer And Geyser Points Of Approved Quality Conforming To Is: 893115 Mm Nominal Bore 96 18.32.1 Constructing Masonry Chamber 30X30X50 Cm Inside, In Brick Work In Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) For Stop Cock, With C.I. Surface Box 100X100X75 Mm (Inside) With Hinged Cover Fixed In Cement Concrete Slab 1:2:4 Mix (1 Cement : 2 Coarse Sand: 4 Graded Stone Aggregate 20 Mm Nominal Size), I/C Necessary Excavation, Foundation Concrete 1:5:10 (1 Cement : 5 Fine Sand : 10 Graded Stone Aggregate 40 Mm Nominal Size) And Inside Plastering With Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) 12 Mm Thick, Finished With A Floating Coat Of Neat Cement Complete As Per Standard Design:With Common Burnt Clay F.P.S (Non Modular) Bricks Of Class Designation 7.5 97 17.73.2 Providing And Fixing Ptmt Towel Rail Complete With Brackets Fixed To Wooden Cleats With Cp Brass Screws With Concealed Fitting Arrangement Of Approved Quality And Colour600 Mm Long Towel Rail With Total Length Of 645 Mm, Width 78 Mm And Effective Height Of 88 Mm, Weighting Not Less Than 190 Gms 98 18.51.1 Providing And Fixing C.P. Brass Long Body Bib Cock Of Approved Quality Conforming To Is Standards And Weighing Not Less Than 690 Gms.15 Mm Nominal Bore 99 50.18.7.2.1 Providing And Fixing Pvc Pipes, Fittings Including Fixing The Pipe With Claps At 1.00 Metre Spacing. This Includes Jointing Of Pipes & Fittings With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer-In-Charge 20 Mm Dia 12Kgf/Cm2 - Internal Work - Exposed On Wall 100 50.18.9.3.2 Providing And Fixing Pvc Pipes Includes Jointing Of Pipes With One Step Pvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineer In Charge. 25 Mm Dia 10Kgf/Cm2 101 50.18.7.6.1 Providing And Fixing Pvc Pipes, Fittings Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer-In-Charge 50 Mm Dia 10 Kfg/Cm - Internal Work- Exposed On Wall 102 50.18.9.7.1 Providing And Fixing Pvc Pipes Includings Of Pipes With One Step Pvc Solvent Cement, Trenching Refilling & Testing Of Joints Complete As Per Direction Of Engineer In Charge. 63 Mm Dia 6Kgf/Cm3 103 50.18.9.9.1 Providing And Fixing Pvc Pipes Includings Jointing Of Pipes With One Step Pvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineer In Charge.110 Mm Dia 6Kgf/Cm2 104 50.18.9.22.1 Providing And Fixing Pvc Moulded Fittings/ Accessories For Rigid Pvc Pipes, Including Jointing With Pvc Solvent Cement - 110 Mm Dia Elbow 105 50.18.9.22.2 Providing And Fixing Pvc Moulded Fittings / Accessories For Rigid Pvc Pipes, Including Jointing With Pvc Solvent Cement - 110 Mm Dia 45 Degree Elbow 106 50.18.9.22.4 Providing And Fixing Pvc Moulded Fittings/ Accessories For Rigid Pvc Pipes, Including Jointing With Pvc Solvent Cement- 110 Mm Dia Bend 107 50.18.9.22.5 Providing And Fixing Pvc Moulded Fittings/ Accessories For Rigid Pvc Pipes Including Jointing With Pvc Solvent Cement 110X110X110 Mm Dia Tee 108 50.18.9.22.7 Providing And Fixing Pvc Moulded Fittings/ Accessories For Rigid Pvc Pipes, Including Jointing With Pvc Solvent Cement - 110X110X75 Mm Dia Door Tee 109 18.58.2.1 Providing And Fixing Ptmt Grating Of Approved Quality And Colour. Rectangular Type With Openable Circular Lid150 Mm Nominal Size Square 100 Mm Diameter Of The Inner Hinged Round Grating 110 51.19.St4 Supplying And Installing Ready Made Pvc Septic Tank Including The Cost Of Carriage, Trenching, Placing At The Level Below Ground Level As Specified As Per The Direction Of Engineer In Charge (Provision For Cc/Rcc/Sand/06Mm Aggregate For The Preparation Of Bed Shall Be Paid Separately) 4. 35 To 50 Flush Capacity 111 18.48 Providing And Placing On Terrace (At All Floor Levels) Polyethylene Water Storage Tank :Isi 12701 Marked, With Cover And Suitable Locking Arrangement And Making Necessary Holes For Inlet, Outlet And Overflow Pipes But Without Fittings And The Base Support For Tank. 112 Od141980/2025-2026 Providing 25Mm/32Mm (3/4 Inch/1 Inch) Public Building Connection With 20Mm (3/4 Inch) Water Meter From Existing Ci Mains Up To 125 Mm Dia., Up To A Length Of 5 M Using 25Mm Indian Standard Class 6 Upvc Pipe And Upvc / Gm / Brass Specials Viz. Brass Ferrule, Gm Full Way Wheel Valve, Elbow, Mta, Fta, Couplers Etc. And Connecting With The Mains, Testing The Joints Etc. Complete Including Trenching And Refilling In All Kinds Of Soil Up To A Depth Of 1.50M For Main Line Tracing And Trench Of Average Cross Section 0.3M X 0.75M For Laying Connection Pipe And Service Pipe, Fixing Water Meter, Lighting, Watching, Providing Caution Boards, Traffic Control Etc. Complete Including Cost Of Materials, Hire For Tools, Cost Of Consumables And Labour Charges , Cost Of Water Meter And Meter Box, Deposit Charges Of Kwa And Including Charges For Cutting The Concrete / Tarred / Bituminous Roads Etc, If Necessary And As Per The Direction Of The Engineer-In-Charge. 113 1)Electrical Works -Ground Floor & First Floor 114 1.10.3 Wiring For Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Medium Class Pvc Conduit, With Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm. Frls Pvc Insulated Copper Conductor Single Core Cable Etc As Required.Group C 115 1.14.2 Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Medium Class Pvc Conduit As Required2X 2.5 Sq. Mm + 1 X 2.5 Sq. Mm Earth Wire 116 1.23.4 Supplying And Fixing Following Piano Type Switch / Socket On The Existing Switch Box/ Cover Including Connections Etc. As Required.3 Pin 5/6 Amp Socket Outlet 117 1.24.3 Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required.15/16 Amp Switch 118 1.24.5 Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required.6 Pin 15/16 Amp Socket Outlet 119 1.12 Wiring For Light/ Power Plug With 2X4 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface/ Recessed Medium Class Pvc Conduit Along With 1 No 4 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable For Loop Earthing As Required. 120 2.3.3 Supplying And Fixing Following Way, Single Pole And Neutral, Sheet Steel, Mcb Distribution Board, 240 Volts, On Surface/ Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Including Earthing Etc. As Required. (But Without Mcb/Rccb/Isolator) 12 Way, Double Door 121 1.25 Supplying And Fixing Two Module Stepped Type Electronic Fan Regulator On The Existing Modular Plate Switch Box Including Connections But Excluding Modular Plate Etc. As Required. 122 5.4 Earthing With G.I. Earth Plate 600 Mm X 600 Mm X 6 Mm Thick Including Accessories, And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Of 2.7 Metre Long Etc. With Charcoal/ Coke And Salt As Required. 123 5.19 Providing And Fixing 4.00 Mm Dia Copper Wire On Surface Or In Recess For Loop Earthing Along With Existing Surface/ Recessed Conduit/ Submain Wiring/ Cable As Required. 124 1.27.2 Supplying And Fixing Following Size/ Modules, Gi Box Alongwith Modular Base & Cover Plate For Modular Switches In Recess Etc As Required.3 Module (100Mmx75Mm) 125 2.14.2 Supplying And Fixing Following Rating, Double Pole, (Single Phase And Neutral),240 Volts, Residual Current Circuit Breaker (Rccb), Having A Sensitivity Current 30 Milli Amperes In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 40 Amps 126 2.10.1 Supplying And Fixing 5A To 32 A Rating, 240/415 Volts, 10 Ka, \\C\\ Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. Single Pole 127 1.14.1 Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Medium Class Pvc Conduit As Required2X1.5 Sq.Mm + 1X1.5 Sq.Mm Earth Wire 128 2.12.1 Supplying And Fixing Following Rating, Double Pole, 240 Volts, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.40 Amps 129 Od123876/2025-2026 Supplying And Fixing Following 32 Amps Modular Dp Switch And Other Accessories Etc Complete 130 Od123878/2025-2026 Supplying And Fixing 14 W Led Connect With Bulk Head Fixing And Other Accessories 131 Od123874/2025-2026 Supply And Fixing Angle Batten With 7/9 Watts Led And Other Accessories 132 Od123877/2025-2026 Supply And Fixing Angle Batten With 14/15 Watts Led And Other Accessories 133 Od123872/2025-2026 Supplying And Fixing 20W Led Tube Set (Approved Brands) And Other Accessories 134 90.4.5.4 Supply, Installation, Testing And Commissioning Of Ceiling Fan Of Following Sizes Including Wiring The Down Rods Of Standard Length (Up To 30 Cm) With 1.5 Sq. Mm Frls Pvc Insulated, Copper Conductor, Single Core Cable Etc. As Required. 1200Mm Sweep - Ceiling Fan Complete With Service Value Minimum 4.0(Cub Meter/Minute/Watt), Air Delivery Minimum 210(Cubic Meter/Minute), Copper Winding Suitable For 230V/240V Single Phase Ac Supply 135 Od123875/2025-2026 Supplying, Installing, Testing And Commissioning Of Wall Mounted Single Phase 2 Wire Energy Meter With Meter Box Poly Carbonate Body Having Range Of 32 Amp With Enclosure Made Out Of Powder Coated 16 Swg Sheet Suitable For Fixing In Surface/ Recess With Fuse Unit 32 Amp With Neutral Link, Its Interconnection Etc. The Enclosure Shall Have Lockable Door With Glass Window And All Mounting Accessories Etc. Complete As Required Including Kseb Charges 136 2)Childrens Play Equipments 137 Od135736/2025-2026 Supply And Fixing ChildrenS Play Equipment Circular See-Saw Including Cost Of All Materials And Labour Charges Etc Complete. 138 Od135738/2025-2026 Supplying And Fixing ChildrenS Play Equipment Step With Slide Including Cost Of All Materials And Labour Charges, Etc. 139 3)Community Hall-Renovation-Civil Works 140 15.28.1 Dismantling Roofing Including Ridges, Hips, Velleys And Gutters Etc., And Stacking The Material Within 50 Metres Lead Of :G.S. Sheet 141 15.19 Dismantling Steel Work Manually / By Mechanical Means In Built Up Sections Without Dismembering And Stacking Within 50 Metres Lead As Per Directions Of Engineer -In- Charge. 142 15.2.2 Demolishing Cement Concrete Manually / By Mechanical Means Including Disposal Of Material Within 50 Metres Lead As Per Direction Of Engineer - In-Charge.Nominal Concrete 1:4:8 Or Leaner Mix ( Including Equivalent Design Mix) 143 13.33.1 Pointing On Stone Work With Cement Mortar 1:3 ( 1 Cement : 3 Fine Sand):Flush/ Ruled Pointing 144 5.1.2 Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement - All Work Up To Plinth Level:1:1:5:3 (1 Cement 1.5 Coarse Sand :3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources) 145 11.41.2 Providing And Laying Vitrified Floor Tiles In Different Sizes (Thickness To Be Specified By The Manufacturer) With Water Absorption Less Than 0.08% And Conforming To Is : 15622, Of Approved Make, In All Colours And Shades, Laid On 20 Mm Thick Cement Mortar 1:4(1 Cement : 4 Coarse Sand), Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete.Size Of Tile 600 X 600 Mm. 146 13.1.1 12 Mm Cement Plaster Of Mix:1:4 ( 1 Cement : 4 Fine Sand) 147 13.91 Removing Dry Or Oil Bound Distemper, Water Proofing Cement Paint And The Like By Scrapping, Sand Papering And Preparing The Surface Smooth Including Necessary Repairs To Scratches Etc. Complete 148 13.43.1 Applying One Coat Of Water Thinnable Cement Primer Of Approved Brand And Manufacture On Wall Surface:Water Thinnable Cement Primer 149 13.60.1 Wall Painting With Acrylic Emulsion Paint Of Approved Brand And Manufacture To Give An Even Shade:Two Or More Coats On New Work 150 13.47.1 Finishing Walls With Premium Acrylic Smooth Exterior Paint With Silicone Additives Of Required Shade:New Work (Two Or More Coats Applied @ 1.43 Ltr/ 10 Sqm Over And Including Priming Coat Of Exterior Primer Applied @ 2.20 Kg/ 10 Sqm) 151 13.88 Removing White Or Colour Wash By Scrapping And Sand Papering And Preparing The Surface Smooth Including Necessary Repairs To Scratches Etc. Complete. 152 13.85.1 Applying Priming Coats With Primer Of Approved Brand And Manufacture, Having Low Voc ( Volatile Organic Compound) Content.With Ready Mixed Pink Or Grey Primer On Wood Work (Hard And Soft Wood ) Having Voc Content Less Than 50 Grams/ Litre 153 13.99.1 Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture Of Required Colour To Give An Even Shade :One Or More Coats On Old Work 154 50.10.1 Steel Work In Built Up G I Tubular ( Round, Square Or Rectangular Hollow Tubes Etc.) Trusses Etc., Including Cutting, Hoisting,Fixing In Position And Applying A Priming Coat Of Approved Steel Primer, Including Welding And Bolted With Special Shaped Washers Etc. Complete 155 50.10.2 Steel Work For Purlin/Single Section With G I Pipes Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer, Including Welding And Bolted With Special Shaped Washers Etc. Complete 156 12.50 Providing And Fixing Precoated Galvanised Iron Profile Sheets (Size, Shape And Pitch Of Cost Index (Place) : Kollam, Gst : 18% Printed On 2026-03-17 13:56:12.13 20 Thickness With Zinc Coating 120 Grams Per Sqm As Per Is: 277, In 240 Mpa Steel Grade, 5-7 Microns Epoxy Primer On Both Side Of The Sheet And Polyester Top Coat 15-18 Microns. Sheet Should Have Protective Guard Film Of 25 Microns Minimum To Avoid Scratches During Transportation And Should Be Supplied In Single Length Upto 12 Metre Or As Desired By Engineer-In-Charge. The Sheet Shall Be Fixed Using Self Drilling/Self Tapping Screws Of Size (5.5X55Mm) With Epdm Seal, Complete Upto Any Pitch In Horizontal/ Vertical Or Curved Surfaces, Excluding The Cost Of Purlins, Rafters And Trusses And Including Cutting To Size And Shape Wherever Required. 157 12.51.1 Providing And Fixing Precoated Galvanised Steel Sheet Roofing Accessories 0.50 Mm (+0.05 %) Total Coated Thickness, Zinc Coating 120 Grams Per Sqm As Per Is: 277, In 240 Mpa Steel Grade, 5-7 Microns Epoxy Primer On Both Side Of The Sheet And Polyester Top Coat 15-18 Microns Using Self Drilling/ Self Tapping Screwscomplete :Ridges Plain (500-600 Mm)
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 1
22.
Public Administrative Department #11300148 AOC
Tender For Construction Of Inspection Banglow, Guest House, Boundary Wall & Garage Near Suklai Head Works Under Extension, Renovation And Modernization Of (Erm), Sukla Irrigation Project Under Pmksy-Aibp For The Year 2021-22. , Construction Of Inspection Banglow, Guest House (Ground Floor). Earth Work : Earth Work In Excavation By Mechanical Means (Hydraulic Excavator) /Manual Means In Foundation Trenches Or Drains (Not Exceeding 1.5 M In Width Or 10 Sqm On Plan), Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soil As Directed, Within A Lead Of 50 M. All Kinds Of Soil. , Excavating, Supplying And Filling Of Local Earth (Including Royalty) By Mechanical Transport Upto A Lead Of 5Km Also Including Ramming And Watering Of The Earth In Layers Not Exceeding 20 Cm In Trenches, Plinth, Sides Of Foundation Etc. Complete. , Steel Work : Steel Reinforcement For Reinforced Cement Concrete Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Upto Plinth Level. Thermo-Mechanically Treated Bars Of Grade Fe-500D Or More , Steel Reinforcement For Reinforced Cement Concrete Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Above Plinth Level. Thermo-Mechanically Treated Bars Of Grade Fe-500D Or More , Cement Concrete Work : Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level : 1:2:4 (1 Cement : 2 Coarse Sand (Zone-Iii) Derived From Natural Sources : 4 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources) , Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level : 1:2:4 (1 Cement : 2 Coarse Sand (Zone-Iii) Derived From Natural Sources : 4 Graded Stone Aggregate 40 Mm Nominal Size Derived From Natural Sources , Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement - All Work Up To Plinth Level : 1:1.5:3 (1 Cement : 1.5 Coarse Sand (Zone-Iii) Derived From Natural Sources : 3 Graded Stone Aggregate 20 Mm Nominal Size De Rived From Natural Sources) , Reinforced Cement Concrete Work In Walls (Any Thickness), Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc. Above Plinth Level Up To Floor Five Level, Excluding Cost Of Centering, Shuttering, Finishing And Reinforcement : And Struts Etc. Above Plinth Level Up To Floor Five Level, Excluding Cost Of Centering, Shuttering, Finishing And Reinforcement : 1:1.5:3 (1 Cement : 1.5 Coarse Sand(Zone-Iii) Derived From Natural Sources : 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources) , Reinforced Cement Concrete Work In Beams, Suspended Floors, Roofs Having Slope Up To 15° Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Window Sills, Staircases And Spiral Stair Cases Above Plinth Level Up To Floor Five Level, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement With 1:1.5:3 (1 Cement : 1.5 Coarse Sand(Zone-Iii) Derived From Natural Sources : 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources). , Providing And Laying Damp-Proof Course 40Mm Thick With Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand (Zone-Iii) Derived From Natural Sources : 4 Graded Stone Aggregate 12.5Mm Nominal Size Derived From Natural Sources) , Shuttering & Formwork : Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For Foundations, Footings, Bases Of Columns, Etc. For Mass Concrete , Lintels, Beams, Plinth Beams, Girders, Bressumers And Cantilevers , Columns, Pillars, Piers, Abutments, Posts And Struts , Suspended Floors, Roofs, Landings, Balconies And Access Platform , Stairs, (Excluding Landings) Except Spiral-Staircases , Pre Construction Anti - Termite Treatment : Diluting And Injecting Chemical Emulsion For Post-Constructional Anti-Termite Treatment (Excluding The Cost Of Chemical Emulsion) : Treatment Of Soil Under Existing Floors Using Chemical Emulsion @ One Litre Per Hole, 300 Mm Apart Including Drilling 12 Mm Diameter Holes And Plugging With Cement Mortar 1 :2 (1 Cement : 2 Coarse Sand) To Match The Existing Floor: With Chlorpyriphos/Lindane E.C. 20% With 1% Concentration , Brick Work : Dry Brick Pitching Half Brick Thick In Drains Including Supply Of Bricks And Preparing The Surface Complete : With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 , Brick Work With Common Burnt Clay Modular Bricks Of Class Designation 7.5 In Foundation And Plinth In: Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) , Half Brick Masonry With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 In Superstructure Above Plinth Level Up To Floor V Level. Cement Mortar 1:4 (1 Cement :4 Coarse Sand) , Wood Work : Providing Wood Work In Frames Of Doors, Windows, Clerestory Windows And Other Frames, Wrought Framed And Fixed In Position With Hold Fast Lugs Or With Dash Fasteners Of Required Dia & Length (Hold Fast Lugs Or Dash Fastener Shall Be Paid For Separately). Sal Wood , Providing And Fixing Panelled Or Panelled And Glazed Shutters For Doors, Windows And Clerestory Windows, Fixing With Butt Hinges Of Required Size With Necessary Screws, Excluding Panelling Which Will Be Paid For Separately, All Complete As Per Direction Of Engineer-In-Charge. (Note:- Butt Hinges And Necessary Screws Shall Be Paid Separately) Second Class Teak Wood 35 Mm Thick Shutters , Pvc Door Frame : Providing And Fixing Factory Made Pvc Door Frame Made Of Pvc Extruded Sections Of Size 75 Mm X 53 Mm, Having Wall Thickness 2.0 Mm (± 0.2 Mm). Both Verticalssides Of The Frame Reinforced With Pvc Profile Of Cross Section Size 28 Mm X 30 Mm X 2 Mm Thickness (± 0.2 Mm) And 75 Mm X 200 Mm Long, Including Reinforcing Both Ends Of The Top Frame With Pvc Profile. Pvc Door Frame And Pvc Reinforcement Profile To Be Mitred Cut, Jointed And Fusion Welded Together, Including Providing And Fixing 3 Nos Of 125 Mm Long Stainless Steel Hinges To Frame, Fixing The Frame With Jamb With Required Nos & Sizes Of Anchor Dash Fastener, All Complete As Per Manufacturers Specification And Direction Of Engineerin-Charge. , Providing And Fixing 37 Mm Thick Factory Made Pvc Door Shutter, Styles And Rails Made Of Pvc Hollow Section Of Size 100 Mm X 37 Mm With Wall Thickness 2 Mm (± 0.2 Mm), With Inbuilt Bead On One Side, Styles And Rails Mitered Cut And Joint At The Corners By Means Of 2 Nos Of Plastic Brackets Of Size 75 Mm X 220 Mm At Each Corner And Stainless Steel Screws, Reinforcing The Hinge Side Of Tyle By Inserting Pvc Profile Of Size 28 Mm X 30 Mm, With Wall Thickness 2 Mm ( ± 0.2 Mm). Lockrail Of Size 100 Mm X 37 Mm, Wall Thickness 2 Mm (+ 0.2 Mm) Will Be Fixed To The Vertical Styles. Providing With Pvc Snapfit Beads And Panel Of Size 100 Mm X 20 Mm, And Inserting 2 Nos Tie Bar Of 6 Mm Dia And Fastening With Nuts And Washers Complete, All As Per Manufacturers Specification And Direction Of Engineer-In-Charge. , Providing And Fixing In Position Collapsible Steel Shutters With Vertical Channels 20X10x2 Mm And Braced With Flat Iron Diagonals 20X5 Mm Size, With Top And Bottom Rail Of T-Iron 40X40x6 Mm, With 40 Mm Dia Steel Pulleys, Complete With Bolts, Nuts, Locking Arrangement, Stoppers, Handles, Including Applying A Priming Coat Of Approved Steel Primer. , Providing And Fixing Aluminium Work For Doors, Windows, Ventilators And Partitions With Extruded Built Up Standard Tubular Sections/ Appropriate Z Sections And Other Sections Of Approved Make Conforming To Is: 733 And Is: 1285, Fixing With Dash Fasteners Of Required Dia And Size, Including Necessary Filling Up The Gaps At Junctions, I.E. At Top, Bottom And Sides With Required Epdm Rubber/ Neoprene Gasket Etc. Aluminium Sections Shall Be Smooth, Rust Free, Straight, Mitred And Jointed Mechanically Wherever Required Including Cleat Angle, Aluminium Snap Beading For Glazing / Paneling, C.P. Brass / Stainless Steel Screws, All Complete As Per Architectural Drawings And The Directions Of Engineer-In-Charge. (Glazing, Paneling And Dash Fasteners To Be Paid For Separately) : For Fixed Portion Less Than 12.50 Kg/Sqm) Anodised Aluminium (Anodised Transparent Or Dyed To Required Shade According To Is: 1868, Minimum Anodic Coating Of Grade Ac 15) , For Shutters Of Doors, Windows & Ventilators Including Providing And Fixing Hinges/ Pivots And Making Provision For Fixing Of Fittings Wherever Required Including The Cost Of Epdm Rubber / Neoprene Gasket Required (Fittings Shall Be Paid For Separately) Powder Coated Aluminium (Minimum Thickness Of Powder Coating 50 Micron) , Providing And Fixing Glazing In Aluminium Door, Window, Ventilator Shutters And Partitions Etc. With Epdm Rubber / Neoprene Gasket Etc. Complete As Per The Architectural Drawings And The Directions Of Engineer-In-Charge . (Cost Of Aluminium Snap Beading Shall Be Paid In Basic Item): With Float Glass Panes Of 5 Mm Thickness (Weight Not Less Than 12.50 Kg/Sqm) , Tiles Works : Providing And Laying Vitrified Floor Tiles In Different Sizes (Thickness To Be Specified By The Manufacturer) With Water Absorption Less Than 0.08% And Conforming To Is: 15622, Of Approved Make, In All Colours And Shades, Laid On 20Mm Thick Cement Mortar 1:4 (1 Cement : 4 Coarse Sand), Jointing With Grey Cement Slurry @ 3.3 Kg/ Sqm Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete. Size Of Tile 600X600 Mm , Providing And Laying Vitrified Tiles In Different Sizes (Thickness To Be Specified By Manufacturer), With Water Absorption Less Than 0.08 % And Conforming To I.S. 15622, Of Approved Make, In All Colours & Shade, In Skirting, Riser Of Steps, Over 12 Mm Thick Bed Of Cement Mortar 1:3 (1 Cement: 3 Coarse Sand), Jointing With Grey Cement Slurry @ 3.3 Kg/ Sqm Including Grouting The Joint With White Cement & Matching Pigments Etc. Complete. Size Of Tile 600X600 Mm , Providing And Fixing M.S. Grills Of Required Pattern In Frames Of Windows Etc. With M.S. Flats, Square Or Round Bars Etc. Including Priming Coat With Approved Steel Primer All Complete. Fixed To Steel Windows By Welding. , Providing And Fixing Stainless Steel ( Grade 304) Railing Made Of Hollow Tubes, Channels, Plates Etc., Including Welding, Grinding, Buffing, Polishing And Making Curvature (Wherever Required) And Fitting The Same With Necessary Stainless Steel Nuts And Bolts Complete, I/C Fixing The Railing With Necessary Accessories & Stainless Steel Dash Fasteners , Stainless Steel Bolts Etc., Of Required Size, On The Top Of The Floor Or The Side Of Waist Slab With Suitable Arrangement As Per Approval Of Engineer-In Charge, (For Payment Purpose Only Weight Of Stainless Steel Members Shall Be Considered Excluding Fixing Accessories Such As Nuts, Bolts, Fasteners Etc.) , Plastering Works : 12 Mm Cement Plaster On The Rough Side Of Single Or Half Brick Wall Of Mix : 1:4 (1 Cement: 4 Fine Sand) , 15 Mm Cement Plaster On The Rough Side Of Single Or Half Brick Wall Of Mix : 1:4 (1 Cement: 4 Fine Sand) , 20 Mm Cement Plaster Of Mix : 1:4 (1 Cement: 4 Fine Sand) , Plinth Protection : Making Plinth Protection 50Mm Thick Of Cement Concrete 1:3:6 (1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20 Mm Nominal Size) Over 75Mm Thick Bed Of Dry Brick Ballast 40 Mm Nominal Size, Well Rammed And Consolidated And Grouted With Fine Sand, Including Necessary Excavation Leveling And Dressing And Finishing The Top Smooth. , Painting : With Ready Mixed Pink Or Grey Primer Of Approved Brand And Manufacture On Wood Work (Hard And Soft Wood , Painting Wood Work With Deluxe Multi Surface Paint Of Required Shade. Two Or More Coat Applied @ 0.90 Ltr/10 Sqm Over An Under Coat Of Primer Applied @0.75 Ltr/10 Sqm Of Approved Brand And Manufacture , With Ready Mixed Red Oxide Zinc Chromate Primer Of Approved Brand And Manufacture On Steel Galvanised Iron/ Steel Works , Painting Steel Work With Deluxe Multi Surface Paint To Give An Even Shade. Two Or More Coat Applied @ 0.90 Ltr/ 10 Sqm Over An Under Coat Of Primer Applied @ 0.80 Ltr/ 10 Sqm Of Approved Brand And Manufacture , Providing And Applying Plaster Of Paris Putty Of 2 Mm Thickness Over Plastered Surface To Prepare The Surface Even And Smooth Complete. , Applying One Coat Of Water Thinnable Cement Primer Of Approved Brand And Manufacture On Wall Surface : Water Thinnable Cement Primer , Finishing Walls With 100% Premium Acrylic Emulsion Paint Having Voc Less Than 50 Gm/Litre And Uv Resistance As Per Is 15489:2004, Alkali & Fungal Resistance, Dirt Resistance Exterior Paint Of Required Shade (Company Depot Tinted) With Silicon Additives. New Work (Two Or More Coats Applied @ 1.43 Litre/ 10 Sqm. Over And Including Priming Coat Of Exterior Primer Applied @ 0.90 Litre/10 Sqm. , Door Window Fittings : Providing And Fixing Aluminium Sliding Door Bolts, Isi Marked Anodised (Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868), Transparent Or Dyed To Required Colour Or Shade, With Nuts And Screws Etc. Complete : 300Mm X 16Mm , Providing And Fixing Aluminium Tower Bolts, Isi Marked, Anodised (Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868 ) Transparent Or Dyed To Required Colour Or Shade, With Necessary Screws Etc. Complete : 300Mm X 10Mm , Providing And Fixing Aluminium Handles, Isi Marked, Anodised (Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868) Transparent Or Dyed To Required Colour Or Shade, With Necessary Screws Etc. Complete : 125Mm , Providing And Fixing Ptmt Butt Hinges With Necessary Screws Etc. Complete. 75X60x10 Mm Fitted With 5.5 Mm Dia M.S. Bright Bar Rod Weighing Not Less Than 34 Gms , Construction Of Inspection Banglow Cum Guest House (First Floor). Steel Work : Steel Reinforcement For Reinforced Cement Concrete Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Above Plinth Level. Thermo-Mechanically Treated Bars Of Grade Fe-500D Or More , Cement Concrete Work : Reinforced Cement Concrete Work In Walls (Any Thickness), Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc. Above Plinth Level Up To Floor Five Level, Excluding Cost Of Centering, Shuttering, Finishing And Reinforcement : 1:1.5:3 (1 Cement : 1.5 Coarse Sand(Zone-Iii) Derived From Natural Sources : 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources) , Reinforced Cement Concrete Work In Beams, Suspended Floors, Roofs Having Slope Up To 15° Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Window Sills, Staircases And Spiral Stair Cases Above Plinth Level Up To Floor Five Level, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement With 1:1.5:3 (1 Cement : 1.5 Coarse Sand(Zone-Iii) Derived From Natural Sources : 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources). , Shuttering & Formwork : Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For Lintels, Beams, Plinth Beams, Girders, Bressumers And Cantilevers , Columns, Pillars, Piers, Abutments, Posts And Struts , Suspended Floors, Roofs, Landings, Balconies And Access Platform , Stairs, (Excluding Landings) Except Spiral-Staircases , Brick Work : Half Brick Masonry With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 In Superstructure Above Plinth Level Up To Floor V Level. Cement Mortar 1:4 (1 Cement :4 Coarse Sand) , Wood Work : Providing Wood Work In Frames Of Doors, Windows, Clerestory Windows And Other Frames, Wrought Framed And Fixed In Position With Hold Fast Lugs Or With Dash Fasteners Of Required Dia & Length (Hold Fast Lugs Or Dash Fastener Shall Be Paid For Separately). Sal Wood , Providing And Fixing Panelled Or Panelled And Glazed Shutters For Doors, Windows And Clerestory Windows, Fixing With Butt Hinges Of Required Size With Necessary Screws, Excluding Panelling Which Will Be Paid For Separately, All Complete As Per Direction Of Engineer-In-Charge. (Note:- Butt Hinges And Necessary Screws Shall Be Paid Separately) Second Class Teak Wood 35 Mm Thick Shutters , Pvc Door Frame : Providing And Fixing Factory Made Pvc Door Frame Made Of Pvc Extruded Sections Of Size 75 Mm X 53 Mm, Having Wall Thickness 2.0 Mm (± 0.2 Mm). Both Verticalssides Of The Frame Reinforced With Pvc Profile Of Cross Section Size 28 Mm X 30 Mm X 2 Mm Thickness (± 0.2 Mm) And 75 Mm X 200 Mm Long, Including Reinforcing Both Ends Of The Top Frame With Pvc Profile. Pvc Door Frame And Pvc Reinforcement Profile To Be Mitred Cut, Jointed And Fusion Welded Together, Including Providing And Fixing 3 Nos Of 125 Mm Long Stainless Steel Hinges To Frame, Fixing The Frame With Jamb With Required Nos & Sizes Of Anchor Dash Fastener, All Complete As Per Manufacturers Specification And Direction Of Engineerin-Charge. , Providing And Fixing 37 Mm Thick Factory Made Pvc Door Shutter, Styles And Rails Made Of Pvc Hollow Section Of Size 100 Mm X 37 Mm With Wall Thickness 2 Mm (± 0.2 Mm), With Inbuilt Bead On One Side, Styles And Rails Mitered Cut And Joint At The Corners By Means Of 2 Nos Of Plastic Brackets Of Size 75 Mm X 220 Mm At Each Corner And Stainless Steel Screws, Reinforcing The Hinge Side Of Tyle By Inserting Pvc Profile Of Size 28 Mm X 30 Mm, With Wall Thickness 2 Mm ( ± 0.2 Mm). Lockrail Of Size 100 Mm X 37 Mm, Wall Thickness 2 Mm (+ 0.2 Mm) Will Be Fixed To The Vertical Styles. Providing With Pvc Snapfit Beads And Panel Of Size 100 Mm X 20 Mm, And Inserting 2 Nos Tie Bar Of 6 Mm Dia And Fastening With Nuts And Washers Complete, All As Per Manufacturers Specification And Direction Of Engineer-In-Charge. , Providing And Fixing Aluminium Work For Doors, Windows, Ventilators And Partitions With Extruded Built Up Standard Tubular Sections/ Appropriate Z Sections And Other Sections Of Approved Make Conforming To Is: 733 And Is: 1285, Fixing With Dash Fasteners Of Required Dia And Size, Including Necessary Filling Up The Gaps At Junctions, I.E. At Top, Bottom And Sides With Required Epdm Rubber/ Neoprene Gasket Etc. Aluminium Sections Shall Be Smooth, Rust Free, Straight, Mitred And Jointed Mechanically Wherever Required Including Cleat Angle, Aluminium Snap Beading For Glazing / Paneling, C.P. Brass / Stainless Steel Screws, All Complete As Per Architectural Drawings And The Directions Of Engineer-In-Charge. (Glazing, Paneling And Dash Fasteners To Be Paid For Separately) : Rust Free, Straight, Mitred And Jointed Mechanically Wherever Required Including Cleat Angle, Aluminium Snap Beading For Glazing / Paneling, C.P. Brass / Stainless Steel Screws, All Complete As Per Architectural Drawings And The Directions Of Engineer-In-Charge. (Glazing, Paneling And Dash Fasteners To Be Paid For Separately) : For Fixed Portion Less Than 12.50 Kg/Sqm) Anodised Aluminium (Anodised Transparent Or Dyed To Required Shade According To Is: 1868, Minimum Anodic Coating Of Grade Ac 15) , For Shutters Of Doors, Windows & Ventilators Including Providing And Fixing Hinges/ Pivots And Making Provision For Fixing Of Fittings Wherever Required Including The Cost Of Epdm Rubber / Neoprene Gasket Required (Fittings Shall Be Paid For Separately) Powder Coated Aluminium (Minimum Thickness Of Powder Coating 50 Micron) , Providing And Fixing Glazing In Aluminium Door, Window, Ventilator Shutters And Partitions Etc. With Epdm Rubber / Neoprene Gasket Etc. Complete As Per The Architectural Drawings And The Directions Of Engineer-In-Charge . (Cost Of Aluminium Snap Beading Shall Be Paid In Basic Item): With Float Glass Panes Of 5 Mm Thickness (Weight Not Less Than 12.50 Kg/Sqm) , Tiles Works : Providing And Laying Vitrified Floor Tiles In Different Sizes (Thickness To Be Specified By The Manufacturer) With Water Absorption Less Than 0.08% And Conforming To Is: 15622, Of Approved Make, In All Colours And Shades, Laid On 20Mm Thick Cement Mortar 1:4 (1 Cement : 4 Coarse Sand), Jointing With Grey Cement Slurry @ 3.3 Kg/ Sqm Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete. Size Of Tile 600X600 Mm , Providing And Laying Vitrified Tiles In Different Sizes (Thickness To Be Specified By Manufacturer), With Water Absorption Less Than 0.08 % And Conforming To I.S. 15622, Of Approved Make, In All Colours & Shade, In Skirting, Riser Of Steps, Over 12 Mm Thick Bed Of Cement Mortar 1:3 (1 Cement: 3 Coarse Sand), Jointing With Grey Cement Slurry @ 3.3 Kg/ Sqm Including Grouting The Joint With White Cement & Matching Pigments Etc. Complete. Size Of Tile 600X600 Mm , Providing And Fixing M.S. Grills Of Required Pattern In Frames Of Windows Etc. With M.S. Flats, Square Or Round Bars Etc. Including Priming Coat With Approved Steel Primer All Complete. Fixed To Steel Windows By Welding. , Providing And Fixing Stainless Steel ( Grade 304) Railing Made Of Hollow Tubes, Channels, Plates Etc., Including Welding, Grinding, Buffing, Polishing And Making Curvature (Wherever Required) And Fitting The Same With Necessary Stainless Steel Nuts And Bolts Complete, I/C Fixing The Railing With Necessary Accessories & Stainless Steel Dash Fasteners , Stainless Steel Bolts Etc., Of Required Size, On The Top Of The Floor Or The Side Of Waist Slab With Suitable Arrangement As Per Approval Of Engineer-In Charge, (For Payment Purpose Only Weight Of Stainless Steel Members Shall Be Considered Excluding Fixing Accessories Such As Nuts, Bolts, Fasteners Etc.) , Plastering Works : 12 Mm Cement Plaster On The Rough Side Of Single Or Half Brick Wall Of Mix : 1:4 (1 Cement: 4 Fine Sand) , 15 Mm Cement Plaster On The Rough Side Of Single Or Half Brick Wall Of Mix : 1:4 (1 Cement: 4 Fine Sand) , 20 Mm Cement Plaster Of Mix : 1:4 (1 Cement: 4 Fine Sand) , Painting : With Ready Mixed Pink Or Grey Primer Of Approved Brand And Manufacture On Wood Work (Hard And Soft Wood , Painting Wood Work With Deluxe Multi Surface Paint Of Required Shade. Two Or More Coat Applied @ 0.90 Ltr/10 Sqm Over An Under Coat Of Primer Applied @0.75 Ltr/10 Sqm Of Approved Brand And Manufacture , With Ready Mixed Red Oxide Zinc Chromate Primer Of Approved Brand And Manufacture On Steel Galvanised Iron/ Steel Works , Painting Steel Work With Deluxe Multi Surface Paint To Give An Even Shade. Two Or More Coat Applied @ 0.90 Ltr/ 10 Sqm Over An Under Coat Of Primer Applied @ 0.80 Ltr/ 10 Sqm Of Approved Brand And Manufacture , Providing And Applying Plaster Of Paris Putty Of 2 Mm Thickness Over Plastered Surface To Prepare The Surface Even And Smooth Complete. , Applying One Coat Of Water Thinnable Cement Primer Of Approved Brand And Manufacture On Wall Surface : Water Thinnable Cement Primer , Finishing Walls With 100% Premium Acrylic Emulsion Paint Having Voc Less Than 50 Gm/Litre And Uv Resistance As Per Is 15489:2004, Alkali & Fungal Resistance, Dirt Resistance Exterior Paint Of Required Shade (Company Depot Tinted) With Silicon Additives. New Work (Two Or More Coats Applied @ 1.43 Litre/ 10 Sqm. Over And Including Priming Coat Of Exterior Primer Applied @ 0.90 Litre/10 Sqm. , Door Window Fittings : Providing And Fixing Aluminium Sliding Door Bolts, Isi Marked Anodised (Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868), Transparent Or Dyed To Required Colour Or Shade, With Nuts And Screws Etc. Complete : 300Mm X 16Mm , Providing And Fixing Aluminium Tower Bolts, Isi Marked, Anodised (Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868 ) Transparent Or Dyed To Required Colour Or Shade, With Necessary Screws Etc. Complete : 300Mm X 10Mm , Providing And Fixing Aluminium Handles, Isi Marked, Anodised (Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868) Transparent Or Dyed To Required Colour Or Shade, With Necessary Screws Etc. Complete : 125Mm , Providing And Fixing Ptmt Butt Hinges With Necessary Screws Etc. Complete. 75X60x10 Mm Fitted With 5.5 Mm Dia M.S. Bright Bar Rod Weighing Not Less Than 34 Gms , Construction Of Inspection Banglow, Guest House (Second Floor). Steel Work : Steel Reinforcement For Reinforced Cement Concrete Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Above Plinth Level. Thermo-Mechanically Treated Bars Of Grade Fe-500D Or More , Cement Concrete Work : Reinforced Cement Concrete Work In Walls (Any Thickness), Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc. Above Plinth Level Up To Floor Five Level, Excluding Cost Of Centering, Shuttering, Finishing And Reinforcement : 1:1.5:3 (1 Cement : 1.5 Coarse Sand(Zone-Iii) Derived From Natural Sources : 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources) , Reinforced Cement Concrete Work In Beams, Suspended Floors, Roofs Having Slope Up To 15° Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Window Sills, Staircases And Spiral Stair Cases Above Plinth Level Up To Floor Five Level, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement With 1:1.5:3 (1 Cement : 1.5 Coarse Sand(Zone-Iii) Derived From Natural Sources : 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources). , Shuttering & Formwork : Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For Lintels, Beams, Plinth Beams, Girders, Bressumers And Cantilevers , Columns, Pillars, Piers, Abutments, Posts And Struts , Suspended Floors, Roofs, Landings, Balconies And Access Platform , Stairs, (Excluding Landings) Except Spiral-Staircases , Brick Work : Half Brick Masonry With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 In Superstructure Above Plinth Level Up To Floor V Level. Cement Mortar 1:4 (1 Cement :4 Coarse Sand) , Wood Work : Providing Wood Work In Frames Of Doors, Windows, Clerestory Windows And Other Frames, Wrought Framed And Fixed In Position With Hold Fast Lugs Or With Dash Fasteners Of Required Dia & Length (Hold Fast Lugs Or Dash Fastener Shall Be Paid For Separately). Sal Wood , Providing And Fixing Panelled Or Panelled And Glazed Shutters For Doors, Windows And Clerestory Windows, Fixing With Butt Hinges Of Required Size With Necessary Screws, Excluding Panelling Which Will Be Paid For Separately, All Complete As Per Direction Of Engineer-In-Charge. (Note:- Butt Hinges And Necessary Screws Shall Be Paid Separately) Second Class Teak Wood 35 Mm Thick Shutters , Pvc Door Frame : Providing And Fixing Factory Made Pvc Door Frame Made Of Pvc Extruded Sections Of Size 75 Mm X 53 Mm, Having Wall Thickness 2.0 Mm (± 0.2 Mm). Both Verticalssides Of The Frame Reinforced With Pvc Profile Of Cross Section Size 28 Mm X 30 Mm X 2 Mm Thickness (± 0.2 Mm) And 75 Mm X 200 Mm Long, Including Reinforcing Both Ends Of The Top Frame With Pvc Profile. Pvc Door Frame And Pvc Reinforcement Profile To Be Mitred Cut, Jointed And Fusion Welded Together, Including Providing And Fixing 3 Nos Of 125 Mm Long Stainless Steel Hinges To Frame, Fixing The Frame With Jamb With Required Nos & Sizes Of Anchor Dash Fastener, All Complete As Per Manufacturers Specification And Direction Of Engineerin-Charge. , Providing And Fixing 37 Mm Thick Factory Made Pvc Door Shutter, Styles And Rails Made Of Pvc Hollow Section Of Size 100 Mm X 37 Mm With Wall Thickness 2 Mm (± 0.2 Mm), With Inbuilt Bead On One Side, Styles And Rails Mitered Cut And Joint At The Corners By Means Of 2 Nos Of Plastic Brackets Of Size 75 Mm X 220 Mm At Each Corner And Stainless Steel Screws, Reinforcing The Hinge Side Of Tyle By Inserting Pvc Profile Of Size 28 Mm X 30 Mm, With Wall Thickness 2 Mm ( ± 0.2 Mm). Lockrail Of Size 100 Mm X 37 Mm, Wall Thickness 2 Mm (+ 0.2 Mm) Will Be Fixed To The Vertical Styles. Providing With Pvc Snapfit Beads And Panel Of Size 100 Mm X 20 Mm, And Inserting 2 Nos Tie Bar Of 6 Mm Dia And Fastening With Nuts And Washers Complete, All As Per Manufacturers Specification And Direction Of Engineer-In-Charge. , Providing And Fixing Aluminium Work For Doors, Windows, Ventilators And Partitions With Extruded Built Up Standard Tubular Sections/ Appropriate Z Sections And Other Sections Of Approved Make Conforming To Is: 733 And Is: 1285, Fixing With Dash Fasteners Of Required Dia And Size, Including Necessary Filling Up The Gaps At Junctions, I.E. At Top, Bottom And Sides With Required Epdm Rubber/ Neoprene Gasket Etc. Aluminium Sections Shall Be Smooth, Rust Free, Straight, Mitred And Jointed Mechanically Wherever Required Including Cleat Angle, Aluminium Snap Beading For Glazing / Paneling, C.P. Brass / Stainless Steel Screws, All Complete As Per Architectural Drawings And The Directions Of Engineer-In-Charge. (Glazing, Paneling And Dash Fasteners To Be Paid For Separately) : Neoprene Gasket Etc. Aluminium Sections Shall Be Smooth, Rust Free, Straight, Mitred And Jointed Mechanically Wherever Required Including Cleat Angle, Aluminium Snap Beading For Glazing / Paneling, C.P. Brass / Stainless Steel Screws, All Complete As Per Architectural Drawings And The Directions Of Engineer-In-Charge. (Glazing, Paneling And Dash Fasteners To Be Paid For Separately) : For Fixed Portion Less Than 12.50 Kg/Sqm) Anodised Aluminium (Anodised Transparent Or Dyed To Required Shade According To Is: 1868, Minimum Anodic Coating Of Grade Ac 15) , For Shutters Of Doors, Windows & Ventilators Including Providing And Fixing Hinges/ Pivots And Making Provision For Fixing Of Fittings Wherever Required Including The Cost Of Epdm Rubber / Neoprene Gasket Required (Fittings Shall Be Paid For Separately) Powder Coated Aluminium (Minimum Thickness Of Powder Coating 50 Micron) , Providing And Fixing Glazing In Aluminium Door, Window, Ventilator Shutters And Partitions Etc. With Epdm Rubber / Neoprene Gasket Etc. Complete As Per The Architectural Drawings And The Directions Of Engineer-In-Charge . (Cost Of Aluminium Snap Beading Shall Be Paid In Basic Item): With Float Glass Panes Of 5 Mm Thickness (Weight Not Less Than 12.50 Kg/Sqm) , Tiles Works : Providing And Laying Vitrified Floor Tiles In Different Sizes (Thickness To Be Specified By The Manufacturer) With Water Absorption Less Than 0.08% And Conforming To Is: 15622, Of Approved Make, In All Colours And Shades, Laid On 20Mm Thick Cement Mortar 1:4 (1 Cement : 4 Coarse Sand), Jointing With Grey Cement Slurry @ 3.3 Kg/ Sqm Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete. Size Of Tile 600X600 Mm , Providing And Laying Vitrified Tiles In Different Sizes (Thickness To Be Specified By Manufacturer), With Water Absorption Less Than 0.08 % And Conforming To I.S. 15622, Of Approved Make, In All Colours & Shade, In Skirting, Riser Of Steps, Over 12 Mm Thick Bed Of Cement Mortar 1:3 (1 Cement: 3 Coarse Sand), Jointing With Grey Cement Slurry @ 3.3 Kg/ Sqm Including Grouting The Joint With White Cement & Matching Pigments Etc. Complete. Size Of Tile 600X600 Mm , Providing And Fixing M.S. Grills Of Required Pattern In Frames Of Windows Etc. With M.S. Flats, Square Or Round Bars Etc. Including Priming Coat With Approved Steel Primer All Complete. Fixed To Steel Windows By Welding. , Providing And Fixing Stainless Steel ( Grade 304) Railing Made Of Hollow Tubes, Channels, Plates Etc., Including Welding, Grinding, Buffing, Polishing And Making Curvature (Wherever Required) And Fitting The Same With Necessary Stainless Steel Nuts And Bolts Complete, I/C Fixing The Railing With Necessary Accessories & Stainless Steel Dash Fasteners , Stainless Steel Bolts Etc., Of Required Size, On The Top Of The Floor Or The Side Of Waist Slab With Suitable Arrangement As Per Approval Of Engineer-In Charge, (For Payment Purpose Only Weight Of Stainless Steel Members Shall Be Considered Excluding Fixing Accessories Such As Nuts, Bolts, Fasteners Etc.) , Plastering Works : 12 Mm Cement Plaster On The Rough Side Of Single Or Half Brick Wall Of Mix : 1:4 (1 Cement: 4 Fine Sand) , 15 Mm Cement Plaster On The Rough Side Of Single Or Half Brick Wall Of Mix : 1:4 (1 Cement: 4 Fine Sand) , 20 Mm Cement Plaster Of Mix : 1:4 (1 Cement: 4 Fine Sand) , Steel Work In Built Up Tubular (Round, Square Or Rectangular Hollow Tubes Etc.) Trusses Etc., Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer, Including Welding And Bolted With Special Shaped Washers Etc. Complete. Hot Finished Welded Type Tubes , Roofing : Providing And Fixing Precoated Galvanised Iron Profile Sheets (Size, Shape And Pitch Of Corrugation As Approved By Engineer-In-Charge) 0.50 Mm (+ 0.05 %) Total Coated Thickness With Zinc Coating 120 B49grams Per Sqm As Per Is: 277, In 240 Mpa Steel Grade, 5-7 Microns Epoxy Primer On Both Side Of The Sheet And Polyester Top Coat 15-18 Microns. Sheet Should Have Protective Guard Film Of 25 Microns Minimum To Avoid Scratches During Transportation And Should Be Supplied In Single Length Upto 12 Metre Or As Desired By Engineer In-Charge. The Sheet Shall Be Fixed Using Self Drilling /Self Tapping Screws Of Size (5.5X 55 Mm) With Epdm Seal, Complete Upto Any Pitch In Horizontal/ Vertical Or Curved Surfaces, Excluding The Cost Of Purlins, Rafters And Trusses And Including Cutting To Size And Shape Wherever Required. , Providing And Fixing Precoated Galvanised Steel Sheet Roofing Accessories 0.50 Mm (+0.05 %) Total Coated Thickness, Zinc Coating 120 Grams Per Sqm As Per Is: 277, In 240 Mpa Steel Grade, 5-7 Microns Epoxy Primer On Both Side Of The Sheet And Polyester To Coat 15-18 Microns Using Self Drilling/ Self Tapping Screws Complete : Using Self Drilling/ Self Tapping Screws Complete : Ridges Plain (500 - 600Mm) , Sound Proof : Providing And Fixing Thermal Insulation With Resin Bonded Fibre Glass Wool Conforming To Is: 8183 Having Density 24 Kg/M3, 50 Mm Thick, Wrapped In 200G Virgin Polythene Bags Fixed To Wall With Screw, Rawel Plug & Washers And Held In Position By Criss Crossing Gi Wire Etc. Complete As Per Directions Of Engineer-In-Charge. , 8 Mm Thick Fully Perforated Calcium Silicate Board Made With Calcareous & Siliceous Materials Reinforced With Cellulose Fiber Manufactured Through Autoclaving Processto Give Stable Crystalline Structure With Minimumcompressive Strength 225 Kg/ Sq. Cm, Bending Strength100 Kg/Sq. Cm , Of Size 595X595 Mm, Having Perforationof Dia. 10 Mm With Minimum Perforated Area 18 % Withnon Woven Tissue On The Back Side, Having An Nrc( Noise Reduction Coefficient) Of 0.85, With 50 Mm Thickrockwool Of 48 Kg /Cum Backing , Providing And Fixing False Ceiling At All Height Including Providing And Fixing Of Frame Work Made Of Special Sections, Power Pressed From M.S. Sheets And Galvanized With Zinc Coating Of 120 Gms/Sqm (Both Side Inclusive) As Per Is : 277 And Consisting Of Angle Cleats Of Size 25 Mm Wide X 1.6 Mm Thick With Flanges Of 27 Mm And 37Mm, At 1200 Mm Centre To Centre, One Flange Fixed To The Ceiling With Dash Fastener 12.5 Mm Dia X 50Mm Long With 6Mm Dia Bolts, Other Flange Of Cleat Fixed To The Angle Hangers Of 25X10x0.50 Mm Of Required Length With Nuts & Bolts Of Required Size And Other End Of Angle Hanger Fixed With Intermediate G.I. Channels 45X15x0.9 Mm Running At The Spacing Of 1200 Mm Centre To Centre, To Which The Ceiling Section 0.5 Mm Thick Bottom Wedge Of 80 Mm With Tapered Flanges Of 26 Mm Each Having Lips Of 10.5 Mm, At 450 Mm Centre To Centre, Shall Be Fixed In A Direction Perpendicular To G.I. Intermediate Channel With Connecting Clips Made Out Of 2.64 Mm Dia X 230 Mm Long G.I. Wire At Every Junction, Including Fixing Perimeter Channels 0.5 Mm Thick 27 Mm High Having Flanges Of 20 Mm And 30 Mm Long, The Perimeter Of Ceiling Fixed To Wall/Partition With The Help Of Rawl Plugs At 450 Mm Centre, With 25Mm Long Dry Wall Screws @ 230 Mm Interval, Including Fixing Of Gypsum Board To Ceiling Section And Perimeter Channel With The Help Of Dry Wall Screws Of Size 3.5 X 25 Mm At 230 Mm C/C, Including Jointing And Finishing To A Flush Finish Of Tapered And Square Edges Of The Board With Recommended Jointing Compound , Jointing Tapes , Finishing With Jointing Compound In 3 Layers Covering Upto 150 Mm On Both Sides Of Joint And Two Coats Of Primer Suitable For Board, All As Per Manufacturers Specification And Also Including The Cost Of Making Openings For Light Fittings, Grills, Diffusers, Cutouts Made With Frame Of Perimeter Channels Suitably Fixed, All Complete As Per Drawings, Specification And Direction Of The Engineer In Charge But Excluding The Cost Of Painting With : Wedge Of 80 Mm With Tapered Flanges Of 26 Mm Each Having Lips Of 10.5 Mm, At 450 Mm Centre To Centre, Shall Be Fixed In A Direction Perpendicular To G.I. Intermediate Channel With Connecting Clips Made Out Of 2.64 Mm Dia X 230 Mm Long G.I. Wire At Every Junction, Including Fixing Perimeter Channels 0.5 Mm Thick 27 Mm High Having Flanges Of 20 Mm And 30 Mm Long, The Perimeter Of Ceiling Fixed To Wall/Partition With The Help Of Rawl Plugs At 450 Mm Centre, With 25Mm Long Dry Wall Screws @ 230 Mm Interval, Including Fixing Of Gypsum Board To Ceiling Section And Perimeter Channel With The Help Of Dry Wall Screws Of Size 3.5 X 25 Mm At 230 Mm C/C, Including Jointing And Finishing To A Flush Finish Of Tapered And Square Edges Of The Board With Recommended Jointing Compound , Jointing Tapes , Finishing With Jointing Compound In 3 Layers Covering Upto 150 Mm On Both Sides Of Joint And Two Coats Of Primer Suitable For Board, All As Per Manufacturers Specification And Also Including The Cost Of Making Openings For Light Fittings, Grills, Diffusers, Cutouts Made With Frame Of Perimeter Channels Suitably Fixed, All Complete As Per Drawings, Specification And Direction Of The Engineer In Charge But Excluding The Cost Of Painting With : Fully Perforated Gypsum Plaster Board Of Size 1200 X 2400X12.5 Mm Having Approx. 15 % Perforated Area With Perforation Size And Pattern As Approved By The Engineerin-Charge And As Per Manufacturers Specification, With All 4 Side Tapered And Backed By Acoustical Tissue With Nrc Value Not Less Than 0.60 , Painting : With Ready Mixed Pink Or Grey Primer Of Approved Brand And Manufacture On Wood Work (Hard And Soft Wood , Painting Wood Work With Deluxe Multi Surface Paint Of Required Shade. Two Or More Coat Applied @ 0.90 Ltr/10 Sqm Over An Under Coat Of Primer Applied @0.75 Ltr/10 Sqm Of Approved Brand And Manufacture , With Ready Mixed Red Oxide Zinc Chromate Primer Of Approved Brand And Manufacture On Steel Galvanised Iron/ Steel Works , Painting Steel Work With Deluxe Multi Surface Paint To Give An Even Shade. Two Or More Coat Applied @ 0.90 Ltr/ 10 Sqm Over An Under Coat Of Primer Applied @ 0.80 Ltr/ 10 Sqm Of Approved Brand And Manufacture , Providing And Applying Plaster Of Paris Putty Of 2 Mm Thickness Over Plastered Surface To Prepare The Surface Even And Smooth Complete. , Applying One Coat Of Water Thinnable Cement Primer Of Approved Brand And Manufacture On Wall Surface : Water Thinnable Cement Primer , Finishing Walls With 100% Premium Acrylic Emulsion Paint Having Voc Less Than 50 Gm/Litre And Uv Resistance As Per Is 15489:2004, Alkali & Fungal Resistance, Dirt Resistance Exterior Paint Of Required Shade (Company Depot Tinted) With Silicon Additives. New Work (Two Or More Coats Applied @ 1.43 Litre/ 10 Sqm. Over And Including Priming Coat Of Exterior Primer Applied @ 0.90 Litre/10 Sqm. , Door Window Fittings : Providing And Fixing Aluminium Sliding Door Bolts, Isi Marked Anodised (Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868), Transparent Or Dyed To Required Colour Or Shade, With Nuts And Screws Etc. Complete : 300Mm X 16Mm , Providing And Fixing Aluminium Tower Bolts, Isi Marked, Anodised (Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868 ) Transparent Or Dyed To Required Colour Or Shade, With Necessary Screws Etc. Complete : 300Mm X 10Mm , Providing And Fixing Aluminium Handles, Isi Marked, Anodised (Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868) Transparent Or Dyed To Required Colour Or Shade, With Necessary Screws Etc. Complete : 125Mm , Providing And Fixing Ptmt Butt Hinges With Necessary Screws Etc. Complete. 75X60x10 Mm Fitted With 5.5 Mm Dia M.S. Bright Bar Rod Weighing Not Less Than 34 Gms , Construction Of Inspection Banglow, Guest House (Inetrnal Electrification) Sub Head -I (Wiring) Wiring For Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Medium Class Pvc Conduit, With Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm. Frls Pvc Insulated Copper Conductor Single Core Cable Etc As Required. A) Group A , Wiring For Twin Control Light Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Medium Class Pvc Conduit, 2 Way Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm. Frls Pvc Insulated Copper Conductor Single Core Cable Etc As Required. , Wiring For Light/ Power Plug With 2X4 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface/ Recessed Medium Class Pvc Conduit Along With 1 No 4 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable For Loop Earthing As Required. , Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface/ Recessed Medium Class Pvc Conduit As Required 2 X 1.5 Sq. Mm + 1 X 1.5 Sq. Mm Earth Wire , 2 X 6 Sq. Mm + 1 X 6 Sq. Mm Earth Wire , Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface/ Recessed Steel/ Pvc Conduit As Required. 3 X 1.5 Sq. Mm , 6 X 1.5 Sq. Mm , 6 X 4 Sq. Mm , Supplying And Fixing Of Following Sizes Of Medium Class Pvc Conduit Along With Accessories In Surface/Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. 20 Mm , 25 Mm , Supplying And Fixing Suitable Size Gi Box With Modular Plate And Cover In Front On Surface Or In Recess, Including Providing And Fixing 3 Pin 5/6 Amps Modular Socket Outlet And 5/6 Amps Modular Switch, Connection Etc. As Required. (For Light Plugs To Be Used In Non Residential Buildings). , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. 3Pin 5/6 Socket Outlet , Sub Head - Ii (Mcb & Dbs ) Supplying And Fixin G Following Way, Single Pole And Neutral, Sheet Steel, Mcb Distribution Board, 240 Volts, On Surface/ Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Including Earthing Etc. As Required. (But Without Mcb/Rccb/Isolator)8 Way, Double Door , Supplying And Fixing Following Way, Horizontal Type Three Pole And Neutral, Sheet Steel, Mcb Distribution Board, 215 Volts, On Surface/ Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Including Earthing Etc. As Required. (But Without Mcb/Rccb/Isolator) 4 Way (4 + 12), Double Door , Supplying And Fixing 5 Amps To 32 Amps Rating, 240/415 Volts, C Curve, Miniature Circuit Bre Aker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.Single Pole , Supplying And Fixing Following Rating, Double Pole, 240 Volts, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 40 Amps , Supplying And Fixing Following Rating, 415 V, 10 Ka, C Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 40/63 A Tp , Sub Head-Iii (Fan,Fittings And Fixtures) Supplying, Installation, Testing And Commissioning Of 1200 Mm Sweep, Bee Five Star Rated, Ceiling Fan With Brush Less Direct Current (Bldc Motor) Not Less Than 32 W, Class Of Insulation B, 3 Nos Blade, 30 Cm Long Down Road, 2 Nos Of Canopies, Shackle Kit, Safety Rope, Copper Winding, Power Factor Not Less Than 0.9, Service Value (Cmm/W) Minimum 6.85 Air Delivery Minimum 215Cmm , 350 Rpm (Tolerance As Per Is:374-2019), Thd Less Than 10% Remote Or Electronic Regulator For Speed Control And All Remaining Accessories I/C Safety Pin, Nut Bolts , Washer, Temperature Rise=75 Degree C(Max. ), Insulation Resistance More Than 2Mega Ohm, Suitable For 230V, 50 Hz Ac Supply, Earthing Etc. Complete As Required. , Supplying, Installation Of Exhaust Fan Sweep Not Less Than 300 Mm In The Existing Opening, And Made Of Aluminium Die-Cast Motor Body, Front Protection Guard, Low Noise Operation, Robust Metal Body,Double Ball Bearing,Anti Dust,High Speed(Minimum 1350 Rpm) & High Air Delivery(Minimum 1000 Cmh) Including Making Good The Damage, Connection, Testing, Commissioning Etc. As Required. , Supplying,Installation, Testing And Commissioning Of Surface Mounted Square/Round Shape Led Downlighter Having Suitable Housing Lumen Efficacy = 100Lm/Watt, System Lumen Output = 1200 Lm, Cri = 80, Power Factor = 0.9 Having Suitable Diffuser And Cct In Between 4000K To 6500 K (I/C Both Limits) Complete With All Accessories Etc. Directly On Ceiling/Wall Including Connection With 1.5 Sq. Mm Frls Pvc Insulated, Copper Conductor, Single Core Cable And Earthing Etc. As Required. , Sub Head-Iv (Service Connection) Laying Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Following Size In The Existing Rcc/ Hume/ Metal Pipe As Required. Upto 35 Sq. Mm , Above 35 Sq. Mm And Upto 95 Sq. Mm , Supplying Of One Number Xlpe Insulated And Pvc Sheathed Aluminium Conductor Armoured Power Cable Of 1.1 Kv Grade With Isi Marked (Is 7098 (Part - I) / 1988 With Amendment Up To Date) Following Sizes. A) 3 ½ X 35 Sq.Mm , B) 3 ½ X 95 Sq.Mm , Supplying And Making End Termination With Brass Compression Gland And Aluminium Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade As Required. A) 3.5 X 35 Sqmm ( 32 Mm ) , B) 3½ X 95 Sq. Mm (45Mm) , Supplying And Fixing Of Light Class G.I. Pipe Of 80 Mm Dia. (Nominal) 3 Metres Length Along The Pole For Protection Of Under Ground Cable As Required. , Sub-Head -V( Lighting Conductor And Earthing ) Providing And Fixing Of Lightning Conductor Finial, Made Of 25 Mm Dia 300 Mm Long, G.I. Tube, Having Single Prong At Top, With 85 Mm Dia 6 Mm Thick G.I. Base Plate Including Holes Etc. Complete As Required. , Providing And Fixing G.I. Tape 20 Mm X 3 Mm Thick On Parapet Or Surface Of Wall For Lightning Conductor Complete As Required. (For Horizontal Run) , Providing And Fixing G.I. Tape 20 Mm X 3 Mm Thick On Parapet Or Surface Of Wall For Lightning Conductor Complete As Required. (For Vertical Run) , Providing And Fixing Testing Joint, Made Of 20 Mm X 3 Mm Thick G.I. Strip, 125 Mm Long, With 4 Nos. Of G.I. Bolts, Nuts, Chuck Nuts And Spring Washers Etc. Complete As Required , Earthing With G.I. Earth Plate 600 Mm X 600 Mm X 6 Mm Thick Including Accessories, And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Of 2.7 Metre Long Etc. With Charcoal/ Coke And Salt As Required. , Providing And Fixing 6 Swg Dia G.I. Wire On Surface Or In Recess For Loop Earthing As Required , Providing And Fixing 6 Swg Dia G.I. Wire On Surface Or In Recess For Loop Earthing Along With Existing Surface/ Recessed Conduit/ Submain Wiring/ Cable As Required. , Providing And Laying Earth Connection From Earth Electrode With 6 Swg Dia G.I. Wire In 15 Mm Dia G.I. Pipe From Earth Electrode Including Connection With G.I. Thimble Excavation And Re-Filling As Required , Providing And Laying G.I. Tape 32 Mm X 6 Mm From Earth Electrode Directly In Ground As Required. , Sub Head-Vii (Air Condition) Supplying, Installation, Testing And Commissioning Of Suitable Tr Capacity 5 Star Rating With Eer Not Less Than 4.3 , Split Type Inverter Air Conditioning Units Suitable For Indoor Unit To Be Fixed On The Wall Having Minimum Cooling Capacity 5400 Kcal/Hr Suitable For Single Phase Ac Supply Complete With Outdoor Unit Having Copper Condenser Coil,Suitable Clamp/Bracket For Fixing Outdoor Unit, Inter Connection With Suitable Copper Pipe Etc. Complete As Required. , Supplying , Installation, Testing And Commissioning Of Automatic Voltage Stabilizer Of Capacity 5 Kva For Air Conditioner With 130-240 Volts Range For Operation Of Air Conditioner Complete With Testing Trail Run Etc Complete As Reqd. , Supplying , Installation, Testing And Commissioning Of Automatic Voltage Stabilizer Of Capacity 5 Kva For Air Conditioner With 130-240 Volts Range For Operation Of Air Conditioner Complete With Testing Trail Run Etc Complete As Reqd. , Supply, Installation Testing & Commissioning Of Rigid Upvc Piping Complete With Fittings, Supports As Per Specifications And Duly Insulated With 6 Mm Thick Closed Cell Nitrile Rubber Insulation. A) 25 Mm Dia ( With 6 Mm Nitrile Rubber Insulation) , Construction Of Inspection Banglow, Guest House (For Sanitary & Water Supply) Providing And Fixing White Vitreous China Pedestal Type Water Closet (European Type W.C. Pan) With Seat And Lid, 10 Litre Low Level White P.V.C. Flushing Cistern, Including Flush Pipe, With Manually Controlled Device (Handle Lever), Conforming To Is : 7231, With All Fittings And Fixtures Complete, Including Cutting And Making Good The Walls And Floors Wherever Required : W.C. Pan With Isi Marked Black Solid Plastic Seat And Lid , Providing And Fixing Wash Basin With C.I. Brackets, 15 Mm C.P. Brass Pillar Taps, 32 Mm C.P. Brass Waste Of Standard Pattern, Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls Wherever Require: White Vitreous China Surgeon Type Wash Basin Of Size 660X460 Mm With A Pair Of 15 Mm C.P. Brass Pillar Taps With Elbow Including Operated Levers , Providing And Fixing Stainless Steel A Isi 304 (18/8) Kitchen Sink As Per Is:13983 With C.I. Brackets And Stainless Steel Plug 40 Mm, Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls Wherever Required : Kitchen Sink With Drain Board 510X1040 Mm Bowl Depth 250 Mm , Providing And Fixing P.V.C. Waste Pipe For Sink Or Wash Basin Including P.V.C. Waste Fittings Complete. Semi Rigid Pipe 40 Mm Dia , Providing And Fixing 600X450 Mm Beveled Edge Mirror Of Superior Glass (Of Approved Quality) Complete With 6 Mm Thick Hard Board Ground Fixed To Wooden Cleats With C.P. Brass Screws And Washers Complete. , Providing And Fixing Toilet Paper Holder : Vitreous China , Providing And Fixing Soil, Waste And Vent Pipes : 100 Mm Dia Sand Cast Iron S&S Pipe As Per Is: 1729 , Providing And Fixing Trap Of Self Cleansing Design With Screwed Down Or Hinged Grating With Or Without Vent Arm Complete, Including Cost Of Cutting And Making Good The Walls And Floors : 100 Mm Inlet And 100 Mm Outlet Sand Cast Iron S&S As Per Is: 3989 , Cutting Chases In Brick Masonry Walls For Following Diameter Sand Cast Iron/Centrifugally Cast (Spun) Iron Pipes And Making Good The Same With Cement Concrete 1:3:6 ( 1 Cement : 3 Coarse Sand :6 Graded Stone Aggregate 12.5 Mm Nominal Size), Including Necessary Plaster And Pointing In Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) : 100 Mm Dia , Providing And Fixing Ptmt Liquid Soap Container 109 Mm Wide, 125 Mm High And 112 Mm Distance From Wall Of Standard Shape With Bracket Of The Same Materials With Snap Fittings Of Approved Quality And Colour, Weighing Not Less Than 105 Gms. , Providing And Fixing Ptmt Towel Ring Trapezoidal Shape 215 Mm Long, 200 Mm Wide With Minimum Distances Of 37 Mm From Wall Face With Concealed Fittings Arrangement Of Approved Quality And Colour, Weighing Not Less Than 88 Gms. , Providing And Fixing Ptmt Towel Rail Complete With Brackets Fixed To Wooden Cleats With Cp Brass Screws With Concealed Fittings Arrangement Of Approved Quality And Colour 600 Mm Long Towel Rail With Total Length Of 645 Mm, Width 78 Mm And Effective Height Of 88 Mm, Weighing Not Less Than 190 Gms , Providing And Fixing Brass Bib Cock Of Approved Quality : 20 Mm Nominal Bor , Providing And Fixing Brass Stop Cock Of Approved Quality : 20 Mm Nominal Bor , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineer In Charge. 15 Mm Dia Nominal Outer Dia Pipes , 20 Mm Dia Nominal Outer Dia Pipes , 25 Mm Dia Nominal Outer Dia Pipes , 32 Mm Dia Nominal Outer Dia Pipes , 40 Mm Dia Nominal Outer Dia Pipes , Providing And Fixing G.I. Pipes Complete With G.I. Fittings And Clamps, I/C Cutting And Making Good The Walls Etc Internal Work - Exposed On Wall 15 Mm Dia Nominal Bore , Providing And Fixing G.I. Pipes Complete With G.I. Fittings Including Trenching And Refilling Etc. Internal Work - Exposed On Wall 20 Mm Dia Nominal Bore , 32 Mm Dia Nominal Bore Metre , 40 Mm Dia Nominal Bore , Providing And Fixing Gun Metal Non- Return Valve Of Approved Quality (Screwed End) : 20 To 40 Mm Nominal Bore , Providing And Fixing Gun Metal Gate Valve With C.I. Wheel Of Approved Quality (Screwed End) 20 Mm Nominal Bore , 32 Mm Nominal Bore , 40 Mm Nominal Bore , Providing And Fixing Gun Metal Non- Return Valve Of Approved Quality (Screwed End) : 15 Mm Nominal Bore , 20 Mm Nominal Bore , 25 Mm Nominal Bore , Providing And Fixing Gun Metal Non- Return Valve Of Approved Quality (Screwed End) : 40 Mm Nominal Bore Horizontal , Vertical , Providing And Fixing Uplasticised Pvc Connection Pipe With Brass Unions : 30 Cm Length 15 Mm Nominal Bore , 20 Mm Nominal Bore , Providing And Placing On Terrace (At All Floor Levels) Polyethylene Water Storage Tank, Is : 12701 Marked, With Cover And Suitable Locking Arrangement And Making Necessary Holes For Inlet, Outlet And Overflow Pipes But Without Fittings And The Base Support For Tank , Tube Well Boring With 100 Mm Diameter Casing Pipe For Hand Pump / Tubewell, In All Soils Except Ordinary Hard Rocks Requiring Blasting, Including Removing The Casing Pipe After The Hand Pump / Tube Well Is Lowered And Tested : Up To 6 Metres Depth , Beyond 6 M And Up To 12 M Depth , Beyond 12 M And Up To Required Depth , Providing And Placing In Position Filters Of 40 Mm Diameter G.I. Pipe With Brass Strainer Of Approved Quality. , Providing And Placing In Position Hand Pump Of Approved Quality For 40 Mm Diameter G.I. Pipe Complete With All Accessories. , Providing And Fixing G.I. Union In G.I. Pipe Including Cutting And Threading The Pipe And Making Long Screws Etc. Complete (New Work) : 50 Mm Nominal Bore , Providing And Fixing Square-Mouth S.W. Gully Trap Class Sp-1 Complete With C.I. Grating Brick Masonry Chamber With Water Tight C.I. Cover With Frame Of 300 X300 Mm Size (Inside) The Weight Of Cover To Be Not Less Than 4.50 Kg And Frame To Be Not Less Than 2.70 Kg As Per Standard Design: 150 X 100 Mm Size P Type With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 , Constructing Brick Masonry Manhole In Cement Mortar 1:4 (1 Cement : 4 Coarse Sand ) With Reinforced Cement Concrete Top Slab With 1:1.5:3 Mix (1 Cement : 1.5 Coarse Sand (Zone-Iii) : 3 Graded Stone Aggregate 20 Mm Nominal Size), Foundation Concrete 1:4:8 Mix (1 Cement : 4 Coarse Sand (Zone-Iii) : 8 Graded Stone Aggregate 40 Mm Nominal Size), Inside Plastering 12 Mm Thick With Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) Finished With Floating Coat Of Neat Cement And Making Channels In Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size) Finished With A Floating Coat Of Neat Cement Complete As Per Standard Design : Inside Size 90X80 Cm And 45 Cm Deep Including C.I. Cover With Frame (Light Duty) 455X610 Mm Internal Dimensions, Total Weight Of Cover And Frame To Be Not Less Than 38 Kg (Weight Of Cover 23 Kg And Weight Of Frame 15 Kg) : With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 , Reducing Socket, Bend, Tee, Etc. , Construction Of Septic Tank. (50 Users) Earth Work In Excavation By Mechanical Means (Hydraulic Excavator) /Manual Means In Foundation Trenches Or Drains (Not Exceeding 1.5 M In Width Or 10 Sqm On Plan), Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soil As Directed, Within A Lead Of 50 M. , Dry Brick Pitching Half Brick Thick In Drains Including Supply Of Bricks And Preparing The Surface Complete : , Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level : , Steel Reinforcement For Reinforced Cement Concrete Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Above Plinth Level. , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For , Suspended Floors, Roofs, Landings, Balconies And Access Platform , Vertical And Horizontal Fins Individually Or Forming Box Louvers Band, Facias And Eaves Boards , Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement - All Work Up To Plinth Level : , 15 Mm Cement Plaster On The Rough Side Of Single Or Half Brick Wall Of Mix : , Cement Plaster Skirting Up To 30 Cm Height, With Cement Mortar 1:3 (1 Cement : 3 Coarse Sand), Finished With A Floating Coat Of Neat Cement. , Retaining Wall Earth Work In Excavation By Mechanical Means (Hydraulic Excavator) /Manual Means In Foundation Trenches Or Drains (Not Exceeding 1.5 M In Width Or 10 Sqm On Plan), Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soil As Directed, Within A Lead Of 50 M. , Dry Brick Pitching Half Brick Thick In Drains Including Supply Of Bricks And Preparing The Surface Complete : , Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level : , Steel Reinforcement For Reinforced Cement Concrete Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Above Plinth Level. , Reinforced Cement Concrete Work In Beams, Suspended Floors, Roofs Having Slope Up To 15° Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Window Sills, Staircases And Spiral Stair Cases Above Plinth Level Up To Floor Five Level, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement With 1:1.5:3 (1 Cement : 1.5 Coarse Sand(Zone-Iii) Derived From Natural Sources : 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources). , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For , Walls (Any Thickness) Including Attached Pilasters, Butteresses, Plinth And String Courses Etc , Lintels, Beams, Plinth Beams, Girders, Bressumers And , Half Brick Masonry With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 In Superstructure Above Plinth Level Up To Floor V Level. , Providing And Fixing Stainless Steel ( Grade 304) Railing Made Of Hollow Tubes, Channels, Plates Etc., Including Welding, Grinding, Buffing, Polishing And Making Curvature (Wherever Required) And Fitting The Same With Necessary Stainless Steel Nuts And Bolts Complete, I/C Fixing The Railing With Necessary Accessories & Stainless Steel Dash Fasteners , Stainless Steel Bolts Etc., Of Required Size, On The Top Of The Floor Or The Side Of Waist Slab With Suitable Arrangement As Per Approval Of Engineer-In Charge, (For Payment Purpose Only Weight Of Stainless Steel Members Shall Be Considered Excluding Fixing Accessories Such As Nuts, Bolts, Fasteners Etc.) , Dismentling Existing A-Type Building Demolishing Reinforced Cement Concrete Work Manually/ By Mechanical Means Including Stacking Of Steel Bars And Disposal Of Unserviceable Material Within 50 Metres Lead As Per Direction Of Engineer - In- Charge. , Dismantling Doors, Windows And Clerestory Windows (Steel Or Wood) Shutter Including Chowkhats, Architrave, Holdfasts Etc. Complete And Stacking Within 50 Metres Lead : Of Area Beyond 3 Sq. Metres , Dismantling Tile Work In Floors And Roofs Laid In Cement Mortar Including Stacking Material Within 50 Metres Lead. For Thickness Of Tiles Above 25 Mm And Up To 40 Mm , Demolishing Brick Work Manually/ By Mechanical Means Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Metres Lead As Per Direction Of Engineer-In-Charge. In Cement Mortar , Dismantling Wood Work In Frames, Trusses, Purlins And Rafters Up To 10 Metres Span And 5 Metres Height Including Stacking The Material Within 50 Metres Lead : Of Sectional Area 40 Square Centimetres And Above , Dismantling Roofing Including Ridges, Hips, Valleys And Gutters Etc., And Stacking The Material Within 50 Metres Lead Of G.S. Sheet , Dismantling Aluminium/ Gypsum Partitions, Doors, Windows, Fixed Glazing And False Ceiling Including Disposal Of Unserviceable Material And Stacking Of Serviceable Material With In 50 Meters Lead As Directed By Engineer-In-Charge. , Boundary Wall With Fencing). Earth Work In Excavation By Mechanical Means (Hydraulic Excavator) /Manual Means In Foundation Trenches Or Drains (Not Exceeding 1.5 M In Width Or 10 Sqm On Plan), Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soil As Directed, Within A Lead Of 50 M. , Dry Brick Pitching Half Brick Thick In Drains Including Supply Of Bricks And Preparing The Surface Complete : , Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level : , Steel Reinforcement For Reinforced Cement Concrete Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Above Plinth Level. , Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement - All Work Up To Plinth Level : , Reinforced Cement Concrete Work In Walls (Any Thickness), Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc. Above Plinth Level Up To Floor Five Level, Excluding Cost Of Centering, Shuttering, Finishing And Reinforcement : , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For , Lintels, Beams, Plinth Beams, Girders, Bressumers And , Columns, Pillars, Piers, Abutments, Posts And Struts , Brick Work With Common Burnt Clay Modular Bricks Of Class Designation 7.5 In Foundation And Plinth In : , 15 Mm Cement Plaster On The Rough Side Of Single Or Half Brick Wall Of Mix : , 20 Mm Cement Plaster Of Mix : , Providing And Applying White Cement Based Putty Of Average Thickness 1 Mm, Of Approved Brand And Manufacturer, Over The Plastered Wall Surface To Prepare The Surface Even And Smooth Complete. , Applying One Coat Of Water Thinnable Cement Primer Of Approved Brand And Manufacture On Wall Surface : Water Thinnable Cement Primer , Finishing Walls With 100% Premium Acrylic Emulsion Paint Having Voc Less Than 50 Gm/Litre And Uv Resistance As Per Is 15489:2004, Alkali & Fungal Resistance, Dirt Resistance Exterior Paint Of Required Shade (Company Depot Tinted) With Silicon Additives. , Fencing With Reinforced Cement Concrete Post Placed At Required Distance, Embedded In Cement Concrete Blocks, Every 15Th Post, Last But One End Post And Corner Post Shall Be Strutted On Both Sides And End Post One Side Only, Provided With Horizontal Lines And Two Diagonals Of Barbed Wire Weighing 9.38 Kg Per 100 Metres (Minimum), Between The Two Posts Fitted And Fixed With G.I. Staples On Wooden Plugs Or G.I. Binding Wire Tied To 6 Mm Bar Nibs Fixed While Casting The Post (Cost Of Reinforced Cement Concrete Posts, Struts, Earth Work And Concrete To Be Paid For Separately) :- Payment To Be Made Per Metre Cost Of Total Length Of Barbed Wire Used. , Land Development Excavating, Supplying And Filling Of Local Earth (Including Royalty) By Mechanical Transport Upto A Lead Of 5Km Also Including Ramming And Watering Of The Earth In Layers Not Exceeding 20 Cm In Trenches, Plinth, Sides Of Foundation Etc. Complete. , O.H. Tank Not Found!!! , Solar Street Light Godox S60 Led Focusing Light, Outdoor & Indoor , Gate Pillarlight For Home Outdoor Garden Post Decorative Lamp , Dg Set , Audio Visual Systems Projector (Sony) , Motorised Screen And Accessories (6Ft / 8 Ft) , Digital Podium All-In-One System , Chairman Unit , Delegate Unit , Amplifier 80 Watt , Microphones , Ceiling Mount Speaker ( 6 Watt) , Wire & Lane Cabling For Speaker , Projector & Amplifier Hdmi Wire Connector Wiring Set , Installation, Testing And Commissioning Charges And Configuration Of The System , M.I. 64 -T.V. 4 Nos. @ Rs. 75000/- Per Nos. , Cctv With Motion Sensor And Sound Recorder Including Supplying & Fitting Fixing (Philips Hsp 3800) , Furniture & Fixture Sofa Set A/ Waiting Hall , B/ Executive Guest Room , C/ Suite Room , Executive Table A/ Executive Guest Room , B/ Suite Room , Executive Chair , Bed A/ Guest Room , B/ Staff Room , C/ Suite Room , D/ Security Room , Matress A/ Guest Room , B/ Staff Room , C/ Suite Room , D/ Security Room , Chair A/ Guest Room , B/ Staff Room , C/ Suite Room I)Type-I , Ii)Type-Ii , D/ Security Room , Bed Sheet A/ Guest Room , B/ Staff Room , C/ Suite Room , D/ Security Room , Pillow A/ Guest Room , B/ Staff Room , C/ Suite Room , D/ Security Room , Blanket A/ Guest Room , B/ Staff Room , C/ Suite Room , D/ Security Room , Mosquito Net A/ Guest Room , B/ Staff Room , C/ Suite Room , D/ Security Room , Bath Towel , Hand Towel , Kitchen Utensil A/ Gas Stove , B/ Pressure Cooker , B/ Cookware Set , C/ Dinner Set , D/ Cup Plate Set , E/ Cutlery Set , F/ Mixture Grinder , G/ Electric Kattle , H/ Microwave Oven , I/ Container , Conference Table , Conference Chair (Elentra-112 Steel Frame Fixed Chair)
Contract Date: Jun 16, 2026 Contract Value : 4.10 Crore
Government Departments No of Bidders 2
23.
Educational and Research Institute #11299551 Price Bid
Tender For Supply Of Library Books , Library Books (Refer Nit) , Industrial Safety And Human Behaviour Kaila 9788174734532 , Engineering Mechanics Vela Murali Bks456005 , Earthquake Resist Design Structural Shashikant Dugg Bks643652 , Surveying And Levelling Subramanian 9780198085423 , Practical Railway Engineering, 2Nd Ed Clifford Bonnett 9780000990136 , Geographic Information Systems Gis For Disaster Management 2Ed Brain 9781032552460 , Design Of Structural Elements Chanakya 9781138046436 , Wind Loading Of Structures 3Rd Edition John D. Holmes 9780367241803 , Structural Analysis 3/Ed Menon 9788184877342 , Concrete Pipes And Pipelines Joshi Bks426990 , Strength Of Materials Basavarajaiah 9788173714580 , Geotechnical Engineering Debashis Moitra 9788173719905 , Textbook Of Environmental Studies For Undergraduate Courses 3 Ed Bharucha 9789389211788 , Intelligent Transportation Systems Srinivasa Kumar 9788195400928 , Transportation Engineering Srinivasa Kumar 9789389211160 , Structural Analysis With Finite Elements Hartmann 9788132208945 , Strength Of Materials Vol 1 Binu Sukumar 9789388005029 , Geospatial Technology Dwivedi 9789380381480 , Heavy Metal And Metalloid Contamination Of Surface And Underground Water Gupta A. 9781032728582 , Fundamentals Of Environmental Engineering Danny D Reible 9781566700474 , Computer-Aided Highway Engineering S Goswami 9781032728483 , Fundamentals Of Hydrology Davie 9781032251936 , Highwall Mining : Applicability, Design & Safety Porathur J. L. 9781032728919 , Environmemtal Pollution Control Engineering 4Ed Rao 9788122472288 , Plane Surveying 3Ed Chandra 9788122438802 , Design Of Reinforced Cement Concrete Vol 1 Structural Elements Bhavikatti 9788122440515 , Strength Of Materials, 2/Ed Jindal 9789352861521 , Fundamentals Of Hydraulic Engineering Sy Houghtalen 9789332507593 , Geotechnical Engineering Coduto,Yeung 9789332587427 , Strenth Of Materials Jindal 9788131759097 , Dynamics Of Structures 2Nd Ed Jain 9789357059350 , Finite Element Method With Cd Eldho Desai Shah 9788131724644 , Soil Mechanics And Foundation Engineering Purushotama Rai 9788131790816 , Engineering Mechanics - Statics & Dynamics Shames Rao 9788177581232 , Dynamics Of Structures In Si Unites 5Ed Chopra 9789353945251 , Elementary Engineering Hydrology Deodhar 9788131708057 , Environmental Studies Basak 9788131721186 , Introduction To Finite Elements In Engineering 5/E Tirupathi 9781009461818 , Strength Of Materials Rao 9781108454285 , Plumbing Engineering Nikhil Anthony 9788119365128 , Fundamental Of Ground Improvement Engi Prof.Dr.R.K. Khit 9788195916948 , Surveying And Levelling : Part - 1 Kanetkar Kulkarni Bks644037 , Surveying And Levelling : Part - 2 Kanetkar Bks644038 , A Textbook Of Strength Of Materials Rajput 9789355010704 , Building Construction Bhavikatti 9789325960794 , Fundamental Of Reinforced Concrete Chandra Bks498526 , Irrigation Engineering And Hydraulic Structures Sharma Bks535826 , Surveying I Anne Mary 9788183717304 , Highway Engineering Subramanian 9788183716888 , Strength Of Materials Bansal Bks534222 , Reinforced Cement Concrete Design (Reinforeced Concrete Structures) Punima 9788131809426 , Building Construction Rangwala Bks502124 , Civil Engineering Drawing Rangwala Bks440591 , Soil Mechanics & Foundation Engineering Modi 9788189401306 , Engineering Materials Rangwala Bks385325 , Bridge Engineering Rangwala Bks554100 , Harbour Dock And Tunnel Engineering Srinivasan Bks502125 , Solid Hazardous Watse Management 2Ed Rao 9789389354621 , Textbook Of Remote Sensing And G.I.S 4Ed Reddy 9789381075975 , Reinforced Concrete Design P.B Sharma 9789391910419 , Energy Environment Ecology And Society Anil Kumar 9788178002576 , Solved Problems In Geotecnical Engineering Sharma 9789395038478 , Highway Engineering Suganthi Bks411034 , Highway And Railway Engineering Santhanam Bks638485 , Construction Materials & Tech Mathankumar Bks638450 , Prefabricated Structures Soundrarajan Bks638488 , Structural Analysis-I Santhanam Bks479564 , Green Building Design Molykutty Bks503088 , Irrigation Engineering Basak 9780074635384 , Estimating Construction Costs Peurifoy 9780071239455 , Design Of Steel Structure Duggal 9780070260689 , Concrete Technology Gambhir 9781259062551 , Engineering Mechanics Timoshenko 9781259062667 , Flow In Open Channels Subramanya 9789353166298 , Reinforced Concrete Design 4Ed Pillai 9789354601026 , Surveying Vol - Ii 5Th Edn Duggal 9789353167523 , Surveying And Levelling Basak 9789332901537 , Prestressed Concrete 6Ed Krishna Raju 9789387886209 , Fluid Mechanics White 9789355322043 , Strength Of Materials Rattan 9789385965517 , Surveying Vol - 1 Duggal 9789353167509 , Environmental Studies-3Ed Joseph 9789352605170 , Construction Planning, Equipment Peurifoy 9780070706996 , Fluid Mechanics Fundamentals And Applic Cengel 9789353166212 , Schaums Outline Of Finite Element Analysis Buchanan 9789389691375 , Wind Energy Theory And Practice 3Ed Ahmed Bks662294 , Bituminous Road Construction In India Kandhal 9789391818821 , Mechanics Of Composite Structures Vasiliev 9781138582101 , Satellite Towns In Neometropolitan Development In India Amit Chatterjee 9789811932052 , Sustainable By Design Walker 9781032973685 , Management Of Quality In Construction Ashford 9781138607163 , Disaster Managament 2/Ed Pandey 9789357461610 , Remote Sensing And Image Interpretation Thomas Lillesand 9789354642104 , Composite Structures Of Steel And Concrete 3Ed Johnson 9788126539819 , Strength Of Materials 2Nd/Ed Debabrata Nag 9788126534876 , Reasoning Ability And Quantitative Aptitude Tcy Online 9788126559008 , Green It Strategies And Applications Using Envir Intell Bhuvan Unhelkar 9781032054025 , Bioenergy For Sustainability And Security Behera 9789381891438 , Textbook Of Engineering Geology Annadurai 9789385259937 , Structural Dynamics Mukhopadhyay 9788180520907 , Matrix And Finite Element Analysis Mukhopadhyay 9788180520754 , Irrigation Engineering & Hydraulic Structures Suresh 9789383656899 , Strength Of Materials 2Ed Vendateshan 9789383656646 , Concrete Technology Job Thomas 9788131526682 , Steel Design Segui 9788131526651 , A First Course In The Finite Element Methods Logan 9789353507855 , Civil Engineering Materials Sivakugan Tuladhar 9789386650382 , Soil And Water Conservation Engineer Fangmeier 9788131524985 , Principles Of Foundation Engineering 9Th Ed Das 9789355738110 , Elements Of Civil Engineering Balasubramanya 9789387511576 , Soil Mechanics & Foundation Engineering Huat Prasad 9788131529591 , Principles Of Foundation Engineering Das 9789386650955 , Analysis Of Structures On Elastic Tsudik 9788131518953 , Strength Of Materials : Mechanics Gupta 9789355737717 , Steel Design With Mt Segui 9789386650887 , Prestressed Concrete Structures, 6Ed Dayaratnam 9788120417915 , Fundamentals Of Reinforced Cement Concrete Designs Gahlot 9789385915611 , Instrumental Methods Of Analysis Willard 9788123909431 , Tb Of Soil Mechanics And Foundation Engineering:Geo Technical Engg Murthy 9788123913629 , Civil Engineering Through Objective Type Questions 3Ed Gupta 9788123907970 , Advanced Reinforced Concrete Design 3Ed Raju 9788123929606 , Design Of Reinforced Concrete Structures 4Ed Dayaratnam 9788120414198 , Structural Dynamics Paz 9788123909783 , Modern Prestressed Concrete Libby Bks465269 , Textbok Of Solid Wastes Managemnt Khan 9788123909448 , Analysis & Design Of Substructures, 2Ed Swami Saran 9788120417007 , Building Repair And Maintance Management Gahlot 9788123912431 , Advanced Foundation Engineering Murthy 9788123915067 , Modern Construction Management 7Ed Harris 9788126572298 , Groundwater Hydrology Rushton 9788126539772 , Textbook Of Highway And Traffic Engineering Saxena 9788123924175 , Airport Engineering Saxena 9788123915500 , Construction Dewatering And Groundwater Control 3Ed Powers 9788126541669 , Quality Management Of Cement Concrete Construction (Pb) Gahlot 9788123916989 , Tb Of Water Supply And Sanitary Engineering Husain 9788120416833 , Design Of Bridges 5Ed Raju 9788120417984 , Essentials Of Bridge Engineering 6Ed Victor 9788120417175 , Building Construction Handbook Chudley 9789381269169 , Design And Construction Of Concrete Shell Roofs Ramasamy 9788123909905 , Strength Of Materials, Vol-Ii:Advanced Theory And Problems Timoshenko 9788123910772 , Construction And Project Managment 2Ed (Pb 2018) Krishnamurthy 9789386217790 , Water And Wastewater Calculations Manual 2Ed Lin 9789353162863 , Design Of Stell Structures Abu-Saba 9788123905389 , Prestressed Concrete Problems And Solutions Raju 9788123925424 , Water Resources And Irrigation Engineering Ganesaguru Bks588955 , Dam Engineering Asthana 9789381891469 , Sedimentary Rocks In The Field A Colour Guide Stow 9781874545699 , Soil Mechanics Basic Concepts & Engineering Aysen 9780415383936 , A Tb Of Fluid Mechanics And Hydraulic Machines Bansal Bks493063 , Intelligent And Sustainable Cement Production Chatterjee A.K. 9781032728445 , Total Quality Management 5Ed Besterfield 9789353066314 , Matrix Methods Of Structural Analysis Kothandaraman 9789357059190 , Hydraulics And Fluid Mechanics Hydraulic Machine Modi , Seth Bks291963 , Limit State Design Of Steel Structures Duggal 9789353164874 , Schaums Outline Of Reinforced Concrete Everard 9789389538656 , Earthquake Resistant Design Of Structures Agarwal Bks344533 , Building Materials Varghese 9788120350915 , Total Quality Management 2Ed Mukerjee 9788119364299 , Principles Of Geotechnical Engineering 10 Th Ed Das 9789355738103 , Building Materials Products Properties And Systems Gambhir 9780071077606 , Gate 2025 Civil Engineering - Guide By Gkp C L Educate 9789356817593 , Gate 2025 Mechanical Engineering Guide Gkp 9789356817746 , Engineering Design Dieter 9789355322258 , Economics And Principles Of Management Vinoth Kumar 9788194244646 , Vector Mechanics For Engineers Dynamics Beer 9789353166656 , Aviation Maintenance Management Kinnison 9780071076838 , Theory Of Machines S S Rattan 9789353166281 , Turbomachinery Dubey 9789353161156 , Engineering Mechanics 4/E Kumar 9780070681811 , Modern Compressible Flow: With Historica Anderson 9789355320070 , Programming In Matlab Patel Mittal 9789332524811 , Finite Element Analysis Moaveni 9788131760642 , Non Conventional Energy Resources Sobh Nath Singh 9789332543577 , Additive Manufacturing And 3D Printing Technology Awari Thorat 9781041049562 , Practical Guide To Vehicle Refinishin Woodstock 9781032963570 , The Internet Of Mechanical Things The Iot Framework Sami Salama Hussen 9781041038573 , Energy Storage Systems And Components Alfred Rufer 9781041049470 , Metal Cutting Theory & Practice Stephenson 9780824758882 , Classical Mechanics Problems And Solutions Carolina C Llie 9781032983608 , Product Design Baxter 9781032967882 , Thermal Measurements & Inverse Tech Orlande 9781439845554 , The Induction Machines Design Handbook Boldea Bks331229 , Modeling And Control Of Engineering Systems Clarence W. De Silva 9781420076868 , Fundametals Of Production Planning And Control Chapman 9788131717394 , Applied Thermodynamics For Engineering Technologist 5Ed Eastop 9788177582383 , Classical Mechaincs Goldstein 9788131758915 , Introduction To Robotics Saha 9789355326461 , Thermodynamics-Basc And Applied Ganesan 9789353161279 , Ethics In Engineering 5/Ed Martin 9789355325075 , Digital Marketing Chaarlas 9788119243983 , Non Conventional Energy Resources Khan 9789352601882 , Supply Chain Logistics Management Bowersox 9789353162580 , Mechanical Metallurgy Appuraj Thiyagrajan Deiter 9781307834840 , Schaums Outline Of Continuum Mechanics Mase 9789389691283 , Schaums Outline Of Statics And Mechanics Of Materials Nash 9789389691399 , Maleev & Hartmans Machine Design 6Ed Grover 9788123926322 , Mass Transfer Theory And Applications Narayanan Bks440952 , Manual Of Fire Safety Prakash 9788123919904 , Gpropulsion Systems For Space Applications Satyanarayana 9789395038553 , Mechanics Of Materials Si Version 5Ed Philpot 9789354643293 , Introduction To Robotics 3/Ed Niku 9789357461306 , Advanced Mechanics Of Materials 6Ed Boresi 9788194726395 , Design And Analysis Of Experiments Douglas & Montgomery 9788126540501 , Machine Component Design Robert C.Juvinall 9788126559732 , Callisters Materials Science And Engineering, 2Nd Ed Balasubramaniam 9788126541607 , Process Dynamics And Control 4Ed Dale Seborg 9789354248429 , Engineering Optimization Theory And Practice 5Ed Rao 9789357461238 , Principles Of Modern Manufacturing Si Version Groover 9788126573059 , Convective Heat And Mass Transfer South Asian Edi Mostafa Ghiassiaan 9781107511811 , Continuum Mechanics Jog C S 9781108437141 , Singers Engineering Mechanics Statics & Dynamics ( Si Units ) 3Ed Vijay Kumar 9788178002194 , Analytical Mechanics Fowles 9788131501115 , Thermal Sciences Potter Scott 9788131529461 , Physical Metallurgy Principles Abbaschian 9788131520697 , Additive Manufacturing Technology Hari Prasad 9789353500481 , Computational Fluid Dynamics & Heat Ghosh Dastidar 9788131533079 , Internet Mrketing With Mt Zahay 9789355734570 , Mechanical Vibrations Theory And Applications Kelly 9788131526033 , Mechanics Of Materials, Enhanced Edi Goodno--Gere 9789355737847 , Fundamentals Of Mechatronics Jouane 9788131526026 , Mechanics Of Materials Strength Of Materials Pilli/Bala 9789386668509 , Workshop Manufacturing Practices Ai Juneja 9789387994614 , The Finite Elements Methods - Its Basis & Fundamentals 7/Ed Zienkiewiez 9789351071587 , Automation And Collaborative Robotics (Dp) Mathews 9781484277102 , The Robotic Process Automation Handbook : A Guide To Implementing Ri Systems Taulli 9781484275306 , Materials Selection In Mechanical Design 5Ed Ashby 9789351073864 , Industry 4.0 : The Industrial Internet Things Gilchrist 9781484249703 , The Finite Element Method A Practical Course 2Ed Liu 9789351071594 , Elasticity-Theory, Applications & Numerics 2Ed Sadd 9789351072270 , Energy Resources And Their Utilisation R.K. Khitoliya 9789394917040 , Workshop Theory And Practice Delilah Sam 9788119365098 , New Persp. In Hybrid Vehicle Technology Samual Rodrigues 9788119365418 , Natural Gas Engineering Selvin 9788119365197 , Machine Shop Theory Samual Rodrigues 9788119205639 , Applied Mechanics Laboratory Samual Lobo 9788119365760 , Robotics: Emerging Opportunities Adrian Dsilva 9788119523702 , Advances In Hypersonic Vehicles Samual Rodrigues 9788119365500 , Machine Elements Samual Rodrigues 9788119205691 , Work And Energy Parth Chavda 9788119365234 , Design Thinking : A Comprehensive Textbook Tiwari 9789357468640 , Welding Technology Sanfras Monteiro 9788119523023 , Combustion Engineering Samual Rodrigues 9788119205943 , Fluid Machinery Noel Vincent 9788119365029 , Renewable Energy Roy 9789384007157 , Engineering Graphics Using Autocad 7/Ed {Pb} Elanchezhian C 789387938564 , Introduction To Micromachining 2Ed Jain 9788184873610 , A Systems Approach To Automotive Technology Erjavac 9788131512111 , Emotionally Intelligent Design Pavliscak 9789352138029 , Mechanics Of Solids Binu Sivakumar 9789380381671 , Mechanics Of Solids Christian Johnson 9789385983085 , Jet Engines Jaganathan 9789380381497 , Essentials Of Management, 11Ed Koontz 9789353168148 , Disaster Management Subramanian Bks481407 , Engineering Fluid Mechanics Kumar Bks613447 , A Textbook Of Fluid Mechanics Rajput Bks648302 , A Textbook Of Thermal Engineering ( Lpspe ) Khurmi Bks613483 , Materials Science And Engineering Raghavan 9788120350922 , Engineering Economics 2Nd Ed Panneerselvam Bks661039 , A Tb Of Theory Of Machine Gupta R Khurmi Bks408347 , Energy Security And Sustainability Shukla A. 9781032728926 , Mechanical Engineering Jain Bks554131 , Engineering Materials And Metallurgy Annamalai 9789386235046 , Kinematics Of Machinery Baskar Bks462932 , Thermal Engineering Swaminathan Bks638475 , Engineering Materials And Metallurgy Baskar Bks638439 , Lean Manufacuring Kalyana Chakravarthy Bks638464 , Elements Of Mechanical Engineering Singh Bks448529 , Fundamentals Of Manifacturing Engineering Singh 9789380156002 , Strength Of Machine Elements Ghorpade 9789384726003 , Observability Engineering Achieving Production Excellence Majors 9789355422996 , Research Methodology 5Ed Kothari 9789389802559 , The Automotive Body Vol 2 Morello 9788132208884 , Kinematics Of Machines Kumar 9789388005425 , Essentials Of Heat And Fluid Flow In Porous Media Narasimhan 9789382127215 , Analysis Of Composite Structures Decolon 9789380931463 , Theory Of Elasticity Chandramouli 9789380381633 , Principles Of Composite Material Mechanics 3Ed Gibson Bks380369 , Introduction To Combustion Engineering Basic And Applied Amitava Sarkar 9789357053129 , Textbook Of Finite Element Analysis Seshu Bks414440 , Engineering Thermodynamics Savithiri Bks442773 , Automobile Engineering Vol-Ii Kirpal Singh 9788180142512 , An Introduction To Mechanical Engine 4Ed Wickert Lewis 9789353507473 , Welding Engineering & Technology Parmar Bks53191 , Manufacturing Technology Vol 1-Foundry Forming Rao 9789353160500 , Manufacturing Technology Singh 9789381162385 , Dynamics Of Machines Balaguru 9789386668608 , Unconventional Machining Vivekanandhan Bks613041 , Basic Civil And Mechanical Engineering Shanmugam 9789355329547 , Engineerin Drawing 2Ed Shah / Rana 9788131710562 , Materials For Engineers And Technicians 7Ed Bolton 9781032973722 , Fuel Cell Technology Handbook Hoogers Bks333321 , Robots And Robotics Miller 9789387572966 , Non Destructive Testing And Materials Vivekanandhan Bks476859 , Engineering Mechanics Nelson 9780070146143 , Engineering Tribology 4Ed Stachowiak 9789351071679 , Materials Selection In Mechanical Design 5Ed Ashby 9789351073864 , Automobile Engineering Ayyappan Karthikeyan Bks464418 , Thermal Engineering Swaminathan Bks638475 , Automobile Engineering Babu Singh Bks587323 , A Textbook Of Production Technology Sharma Bks479783 , A Textbook Of Mechatronics Rajput Bks554009 , Automobile Engineering Jain 9780070445291 , Engineering Mechanics Statics & Dynamics Khanchani 9788180521089 , Basic Mechanical Engineering Prabhu 9788183715737 , Powder Metallurgy Ramakrisnan 9789381714485 , Additive Manufacturing Technology Hari Prasad 9789353500481 , Switching And Finite Automata Theory Jha 9780521176804 , Introduction To Mechanics 2Nd Ed Mahendra K Verma 9788173719813 , Basic And Applied Thermodynamics - A Ready Recknor Bhat 9789388005074 , Basic Refrigeration And Airconditioning 4Ed Ananthanarayanan 9781259062704 , Engineering Mechanics Applied Mecha Gupta 9789353505240 , Mechatronics Sathish Kumar Bks476759 , Automobile Engineereing Vol I Singh Bks247106 , Process Planning And Cost Estimating Selvakumar Bks480422 , Non Conventional Energy Resources Sawhney 9788120346093 , Non Conventional Energy Resources Sobh Nath Singh 9789332543577 , Introduction To Micromachining 2Ed Jain 9788184873610 , Vector Mechanics For Engineers Statics/Dynamics (Sie) Beer 9789353166625 , Fluid Mechanics &Hydraulics Rev &Updated Edn Ukarande 9789381162538 , Mechanical Measurements - Revision 6Ed Beckwith 9789353945633 , Vibration Monitoring Testing And Instrumentation C W.De Silva 9781032292137 , A Treatise On Turbomachines Gopalakrishnan Bks321517 , Construction Materials Vs Karthikeyan Bks476834 , Design Of Machine Elements Bhandari 9789390177479 , Mechanical Vibrations Bhava 9788131732489 , Design Of Transmission Systems Baskar Bks476758 , Engineering Materials And Metallurgy Baskar Bks638439 , Manufacturing Technology Vivekanandhan Bks638476 , Design Of Machine Elements Arunraja Bks638441 , Mechanical Vibrations Nag 9788126530908 , Power Plant Engineering Dhanasekar Bks505300 , Statistical Quality Control A Modern Introduction 6Ed Montgomery 9788126525065 , Additive Manufacturing Technologies Shiva Ahuj Shukla 9789357462419 , Hydraulics And Pneumatics Dixon Bks638479 , Engineering Principles Of Ground Modification Hausman 9789351341871 , Engineering Thermodynamics 6Ed Nag 9789352606429 , Refrigeration And Air Conditioning Arora 9789390385843 , Enterprise Resource Planning 4Th Edn Leon 9789353167820 , Foundations Of Material Science And Engg 6Th Edn Smith 9789355322173 , Shigleys Mechanical Engineering Design Budynas 9789390219636 , General Studies Paper - I ( 2025 ) Mhe 9789355327796 , Erp Demystified 3/Ed Leon 9789383286676 , Heat And Mass Transfer 6Ed Cengel 9789390185283 , Engineering Noise Control: Theory And Practices 4Ed Bies 9780415487078 , Rapid Prototyping And Engineering Applications Frank W.Liou 9781138569577 , Strength Of Materials Vol Ii Binu Sukumar 9789388005418 , Mechatronics A Foundation Course Clarence W.De Silva 9781138569553 , Design And Analysis Of Randomized Algorithms Hromkovic 9788132231592 , Metrology And Measurements Annamalai 9789388005463 , Fluid Mechanics And Machinery Molykutty 9789391549725 , Micro Electro Mechanical System Design Allen 9780824758240 , Micromachining Of Engineering Materials J Mcgeough 9781032419794 , Gas Turbine Combustion-3 Rd Ed Lefebvre 9781138569584 , Ergonomics Laboratory Exercises Joseph Gallwey 9781032973005 , Introduction To Biofuels Mousdale 9781439812075 , Environmental Engineering Charles Monteiro 9788119205509 , Power Plant Engineering Lijo Thomas 9788119365036 , Industrial Engineering Richard Carvalho 9788119205523 , Design & Operation Of Heat Exchanger Gerhard Rott 9788119365425 , Hydro Power Gerhard Rott 9788119205912 , Air Conditioning And Ventilation Systems Lijo Thomas 9788119365401 , Materials Science And Engineering Raghavan 9788120350922 , Automation And Collaborative Robotics (Dp) Mathews 9781484277102 , Design Management : Create, Develop And Lead Effective Design Teams Picchi 9781484283615 , Heat And Mass Transfer 2Ed Karwa 9789811926099 , Testing Of Metallic Materials 2Ed Suryanarayana 9788178001340 , Introduction To Engineering Materials 2/Ed Murray George 9781032530772 , Mechanics Of Composite Materials 2/Ed Jones R.M 9781138571075 , Reliability Evaluation Of Enginnering Systems 2Ed Billinton 9788181285522 , Workshop Practice Manual 6/Ed Reddy 9788178003078 , Finite Element Analysis 2D Lakshmi Narasai 9789389354225 , Engineering Mechanics Pb Lakshmi 9789390211609 , Engineering Mechanics 2Ed Harbola 9788131518298 , Environmental Science And Engineering Rajesh Gopinath 9789387511569 , Materials Science And Engineering Periodical Renewal Gilmore 9788131520451 , Environmental Science With Mt 16 Th Ed Miller 9789355738899 , Fluid Mechanics Munson Huebsch 9788126553433 , Engineering Mechanics: Dynamics, Si Version Meriam Bolton 9788126565375 , Engineering Mechanics Statics And Dynamcs James Meriam Kraige 9789354248566 , Engineering Fluid Mechanics Elger 9788126564491 , Engineering Mechanics Applied Mecha Gupta 9789353505240 , Machine Design Data Book Ramana 9789387593879 , Heat Transfer Alan 9789332575066 , Theory Of Machines 3Ed Bevan 9788131729656 , Introduction To Enviromental Engineering And Science Masters 9789332549760 , Heat And Mass Transfer Mayilsamy 9788131733837 , Engineering Thermodynamics 4Ed Rogers 9788131702062 , Operations Research :An Introduction-10Th Ed Hamdy Taha 9789352865277 , Engineering Mechanics - Statics & Dynamics Shames Rao 9788177581232 , Automation, Production Systems, And Computer - Integrated Manufacturing 5Th Ed Groover 9789361592959 , Introduction To Materials Science For Engineers 9E/D Shackelford 9789357059978 , Fundamentals Of Engineering Drawing Luzadder 9789332549982 , Engineering Materials Properties And Selection 9Ed Budinski Naraimhulu 9789332574045 , Thermodynamics Rajadurai Bks471287 , Environmental Science And Engineering Kaushik 9788122436471 , Engineering Optimization 4Ed Rao 9789395161800 , Cad/Cam/Cim 5Ed Radhakrishnan 9789395161855 , Finite Element Analysis With Ansys Workbench Tickoo 9789355513007 , Industrial Waste Management Mathankumar Bks480053 , Metrology And Measurements Vivekanandan Bks638442 , Finite Elements Analysis Baskar Bks534307 , Environmental And Agriculture Kavitha Bks638465 , Energy Materials Bandarenka A.S 9781032530789 , Digital Twin Ranjan Ganguli 9781032934198 , Industry 5.0 The Future Of The Industrial Economy Uthayan 9781032600130 , Quantum Computation Helmut Bez 9781032983738 , Wind Electrical Systems Bhadra, 9780195670936 , Metal Fatigue In Engineering Stephens 9788126539215 , Introduction To Industrial Internet Of Things And Industry 40 Sudip Misra 9781032146751 , Sustainable Manufacturing For Industry 4.0 Jayakrishna K. 9781032728728 , Reverse Supply Chains: Issues And Analysis Gupta S.M. 9781032729039 , Industry 5.0 The Future Of The Industrial Economy Uthayan 9781032600130 , Gas Turbine Heat Transfer Cooling Je-Chin Han, Sandip Dutta 9781439855683 , First Course In Aerial Robots And Drones (A) Bestaoui Sebbane 9781032963518 , Handbook Of Induction Heating Rudnev 9780824708481 , Fracture Mechanics (Forth Ed) T.L Anderson 9781032292120 , Fire Safety Engg Design Of Structures, 2Ed Purkiss 9788131220085 , Future Energy Improved Sustainable And Clean Opitons Letcjer 9788131220849 , Introduction To Finite Elements In Engineering 5/E Tirupathi 9781009461818 , Fundamentals Of Gas Dynamics Babu 9781910390009 , Fundamentals Of Propulsion Babu 9788180522529 , Engineering Metrology 3Rd Ed Narayana Bks396066 , Engineering Mechanics Kumaravelan Bks315205 , General Aptitude For Competitive Examinations Pattanaik Bks670722 , Dictionary Of Heat Power Engineering Ramalingam 9789386923035 , Environmental Pollution Principles Narayana Bks353570 , Production Processes Luqman 9788123918983 , Tractors And Their Power Units, Hb Lijiedahal 9788123905013 , Metal Cutting Principles Shaw 9788123901367 , Sheet Metal Press Tools Design And Making A Practical Approach Luqman 9788123925134 , Solid State Physics Wahab 9788184877786 , Practical Non - Destructive Testing, 3Ed Baldev Raj 9788173197970 , Mechanics Of Machines, 3Ed Ramamurti 9788173198922 , Handbook On Quality And Productivity Improvement Of Concrete Nayak 9788184876390 , Environmental Studies 4Ed Rajagopalan 9789354978944 , Finite Element Methods Dhanraj 9780198073901 , Fluid Dynamics Raisinghania Bks320511 , Entrepreneurship 11/Ed Hisrich 9789390113309 , Thermodynamics 9Th Ed Cengel 9789353165741 , Cad / Cam : Computer - Aided Design & Manufacturing Groover 9788177584165 , Engineering Vibration, 4/E Inman 9789332518483 , Thermodynamics 9Th Ed Cengel 9789353165741 , Schaums Outline Of Mechanical Vibration Graham Kelly 9789389538861 , Enterprise Resource Planning Singla 9789360531485 , Machine Drawing 51Ed Bhatt 9789385039560 , Heat Treatment : Principles And Techniques 3Ed Rajan 9788119364077 , Total Quality Management 2Ed Mukerjee 9788119364299 , Heat Treatment : Principles And Techniques 3Ed Rajan 9788119364077 , Operations Research Panneerselvam 9789354437892 , Design Thinking Teun Den Dekker 9781032786018 , Aeroplane Ramalingam 9788193103159 , Faqs In Control Systems Engineering Pattanaik 9789394639003 , Mass Transfer - Theory & Practice Begum/Anantharaman 9788120341692 , Total Quality Management 5Ed Besterfield 9789353066314 , Production &Operations Management 3Ed Panneerselvam Bks477079 , Manufacturing Technology Vol 2-Metal Cutting Rao 9789353160524 , Engineering Drawing Agrawal 9789353167448 , Cad / Cam : Computer - Aided Design & Manufacturing Groover 9788177584165 , Engineering Mechanics : Statics & Dynamics Kottiswaran Bks307984 , Power Plant Engineering Hegde 9789332534100 , Hydraulics And Fluid Mechanics Hydraulic Machine Modi , Seth Bks291963 , Fundamentals Of Heat And Mass Transer Kothandaraman Bks481435 , Alternative Fuels For Ic Engines Krishnasamy 9789364441995 , Mechatronics Electronic Control Systems In Mechanical And Electrical Eng Bolton 9789357052849 , Manufacturing Technology Vol 2-Metal Cutting Rao 9789353160524 , Fundamentals Of Heat And Mass Transer Kothandaraman Bks481435 , Mechatronics Electronic Control Systems In Mechanical And Electrical Eng Bolton 9789357052849 , Production &Operations Management 3Ed Panneerselvam Bks477079 , Engineering Drawing Agrawal 9789353167448 , Mass Transfer - Theory & Practice Begum/Anantharaman 9788120341692 , Industrial Robotics Control Frigeni 9781484294154 , Gate 2025 Production And Industrial Eng Gkp 9789356818170 , Engineering Vibration, 4/E Inman 9789332518483 , Fundamentals Of Engg Heat And Mass Transfer-5Ed Sachdeva 9789386070968 , Internet Of Nanothings And Wireless Body Area Networks Fadi 9781032599144 , Modern Machining Processes Pandey 9789386761835 , Materials Science For Mechanical Engineering Palanisamy 9789386923059 , Materials Science For Mechanical Engineering Palanisamy 9789386923059 , Textbook Of Fluid Dynamics Chorlton 9788123908816 , Engineering Mechanics : Statics & Dynamics Kottiswaran Bks307984 , Robotics Rajmohan Bks480419 , Hmt Data Book Kothandaraman 9788812243594 , Design Data (Data Book) Psg Bks58578 , Digital Signal Processing 2Ed Paulo Diniz 9781108406703 , 8086 Microprocessor And Applications 3Ed Kani 9789354661327 , Wireless Telecommunication System & Network Mullett 9788131520123 , Operational Amplifiers & Linear Integrated Circuits Lal Kishore 9788177585667 , Mobile Computing Principles Bfar 9780521696234 , Microprocessors & Programmed Logic 2Ed Short 9788131709160 , Design With Pic Microcontroller Peatman 9788177585513 , Digital Systems Design With Access Code Nagoor Kani 9789354667688 , Introduction To Biomems Folch 9781032568225 , Introduction To Biomedical Equipment Technology 4Ed Carr 9788177588835 , Antennas & Wave Propagation Raju 9788131701843 , Raspberry Pi For Dummies Cook 9789357460422 , Digital Signal Processors : Architectures --Op Kuo 9788131717936 , Principles Of Electromagnetics, 6Ed Sadiku 9780199461851 , Advanced Digital Design With The Verilog Michael.D.Ciletti 9789332584464 , Neural Networks Kumar 9781259006166 , Embedded System 2Nd Ed Peckol 9789357463966 , Microprocessor And Peripherals Chowdhury Bks405737 , Networks & Systems Roy Choudhury 9789389802535 , Microcontroller Theory And Application With The Pic Rafiquzzaman 9788126548354 , Digital Signal Processing For Anna University Kani 9789354661006 , Digital Signal Processing 3Ed Kani 9789354661167 , Analog And Pulse Circuits Lakshmaiah D 9789389354201 , Electronic Devices And Circuits Orient 9789386235305 , Quantum Chemistry 7 Ed Levine 9789332558533 , Engineering Circuit Analysis 9/Ed Hayt 9789390185139 , Gate 2025 Electronics And Communication Eng.Guide Gkp 9789356819306 , Chip Design For Submicron Vlsi : Cmos Layout And Simulation Uyemura 9788131501955 , Microelectronics Neamen 9789354601637 , Neural Networks And Learning Machines Haykin 9789332570313 , Electronic Circuits : Fundamentals And Applications 5Ed Tooley 9781032726687 , A Course In Digital Signal Processing Pucca Bundh Porat 9788126534913 , Signals And System Apte 9781316615393 , Digital Design 6Ed Mano 9789353062019 , Principles Of Signal Processing And Liner System Lathi 9780198062288 , Fiber Optic Communications 5Ed Palais 9788131717912 , Circuits And Networks Sudhakar 9789339219604 , Introduction To Communication Systems Madhow 9781316608241 , Analog Communication Rao 9780070704800 , Arduino Based Embedded Systems Singh 9781032964058 , Next Generation Wireless Lans 2Nd Ed Perahia 9781107414617 , Arm Microprocessor System Tahir 9781138387539 , Digital Communication Mutagi Bks478677 , Advanced Microprocessors & Peripherals Bhurchandi 9781259006135 , Vlsi Design Chitra 9788183716598 , Television And Video Engineering Salai Thillai 9788183712194 , The Design Of Cmos Radio Frequency Integrated Circuits Lee 9780521613897 , Network Security : Private Communication In A Public World Charlie Kaufman 9788196874339 , Sensors And Transducers Patranabis 9788120321984 , Neuro Fuzzy And Soft Computing Jang Sun Mizutani 9789332549883 , Network Analysis Channa Venkatesh 9788131533215 , Circuits Carlson 9788131505861 , Op Amps And Linear Integrated Circuits : Concepts And Applications Fiore 9788131512340 , Mobile Computing Principles Bfar 9780521696234 , Instrumental Methods Of Analysis Willard 9788123909431 , Vlsi Circuits And Embedded Systems Hasan Babu 9781032906003 , Computer Organization And Embedded System-6 Th Ed Hamacher 9789339218317 , Network Analysis And Synthesis, 2Ed Singh 9789353166724 , Handbook Of Biomedical Instrumentations Khandpur 9789355328021 , Security And Privacy In Internet Of Things Lots Hu Fei 9781032707150 , Television & Video Engineering Veeralakshmi 9789380156699 , Power Quality Sankaran 9781138569249 , Introduction To Microcontroller Programming For Power Electronic Control Applications Rossi 9781032972183 , Communications System Laboratory Preetham Kumar 9781138603288 , Digital Signal Processing And Its Applications Senthil Kumar 9788195268726 , Multimedia Enabled Sensors In Iot Fadi 9781032599205 , Novel Wearable Antennas For Communication And Medical System Albert Sabban 9781041049579 , Internet Of Things Using Single Board Computers : Principles Of Iot And Python Programming Kanagachidam Baresan 9781484299258 , Handbook Of Optical Communication Networks Ilyas 9781498798037 , Communications System Laboratory Preetham Kumar 9781138603288 , Digital Watermarking And Steganography 2Nd Edition Shih 9781032972121 , Propagation Handbook For Wireless Communication System Design Crane 9780849308208 , The Internet Of Things In The Cloud Honbo Zhou 9781498770354 , Arduino Based Embedded Systems Singh 9781032964058 , 5G Mobile Communications Concepts And Technologies Saad Asif 9781032663159 , Electronic Devices 10Ed Robert Floyd 9789354493935 , Semiconductor Physics And Devices, 3Ed Sze 9789354243226 , Digital Fundamentals 11Ed Floyd 9789332584600 , Electronic Devices And Circuits--11 Ed Boylestad Nashelsky 9789332542600 , The 8051 Microcontrollers & Embedded Systems 2Ed Mazidi 9788131710265 , A System C Primer 2Ed Bhasker 9788178001418 , Household Electricity And Appliances P.B Bhagava 9789390211265 , Image Processing Analysis And Mach Sonka 9789386858146 , Verilog Hdl 2Ed +Cd Palnitkar 9788177589184 , Modern Semiconductor Devices For Integration Hu 9788131730249 , Analog Integrated Circuit Design Isv 2Nd Ed Chan Carusone 9788126543939 , Textbook Of Digital Electronics Vasudevan 9789381714539 , Microwave Engineering 4Ed Das 9789390113347 , Analysis Of Microcontrollers For The Students Kothari 9789381714294 , Digital Signal Processing : For C.S.I.T Palani 9789380618388 , Fundamentals Of Digital Images Processing Jain 9789332551916 , Signals And Systems Sreenivasa Reddy 9789389354041 , Satellite Communications Pratt 9789354243035 , Analog Signals And Systems Kudeki 9788131787984 , Embedded Systems Handbook 2Ed System Design And Verification Zurawski Bks331222 , Vlsi Design And Eda Tools 2Nd Ed Sarkar 9788183714976 , Vlsi Design Das 9780198094869 , 8085 Microprocessor Pramod Borole 9789382127581 , Fundamentals Of Communication Systems Proakis 9788131705735 , Short Range Wireless Communication 3Ed Bensky 9789351073994 , Introduction To Fiber Optics Ghatak Ajoy 9781316644010 , The Definitive Guide To Arm Cortex M3 And Cortex M4 Processors Yiu 9789351071754 , Rf Circuit Design Ludwig 9788131762189 , Electric Circuits For Be/Betch 2Ed Kani 9789354663925 , Control Systems Nagoor Kani 9789389239010 , Digital Logic Circuits Nagoor Kani 9789354669989 , Microwave And Rf Design Steer 9789380381305 , Electrical Measurement And Measuring Instruments Rajput Bks543993 , Digital Signal Processing 3Ed Kani 9789354661167 , A Handson Course In Sensors Using The Arduino And Raspberry Pi Ziemann Volker 9781032791470 , Signal And Systems Simplified 2Ed Nagoor Kani 9789354661013 , Basic Electrical And Electronics Engineering 2/Ed Bhattacharya 9789332586505 , Ad Hoc Wireless Networks : Architectures & Protocols Murthy 9788131706886 , Ad Hoc And Wilreless Sensor Network Athawale 9789356066137 , Digital Circuits Design Kothari 9789332543539 , Solid State Electronic Devices Streetman 9789332555082 , Wireless Communication Goldsmith 9780521704168 , Probability And Stochastic Processes 3Ed Yates 9789354243455 , Signals, Systems And Inference Oppenheim 9789356064676 , Electromagnetic Field And Waves Salivahanan 9788119896677 , Analog Design For Cmos Vlsi Systems Maloberti 9788181284341 , Vlsi Design Michael 9780849318764 , Cognitive Sensors And Iot Fadi 9781032599236 , Digital Design & Computer Organization Farhat 9780849311918 , Digital Intergrated Circuits Evegni 9780849330575 , Introduction To Iot With Machine Learning And Image Processing Using Raspberry Pi Ambaji Kulkarni 9781032966885 , Basic Electrical And Electronics Engineering Murugan 9789384726072 , Adaptive Antenna Arrays Chandran 9788181289322 , Networks Lines & Fields 2Ed Ryder 9789332559516 , Data Compression : The Complete Reference Salomon 9788184898002 , Electric Circuits Bell Bks321194 , Digital Signal Processing Oppenheim 9789332550339 , Iot Standards With Blockchain : Enterprise Methodology For Internet Of Things Upadrista 9781484284278 , An In Depth Guide To Mobile Device Forensics Chuck Easttom 9781032785905 , Digital Signal Processing Oppenheim 9789332550339 , Digital Modulation & Coding Wilson 9788131721438 , Fundamentals Of Mobile Computing 2Ed Pattnaik Bks534717 , Introduction To Iot With Machine Learning And Image Processing Using Raspberry Pi Ambaji Kulkarni 9781032966885 , Biomedical Instrumentations And Measurements Cromwell 9789332556911 , Artificial Neural Networks For Engineers And Scientists Chakraverty S. 9781032729121 , Digital Communication Bhattacharya 9780070591172 , Signals And Systems 2/Ed Oppenheim 9789332550230 , Fundamentals Of Modern Vlsi Devices Yuan Taur 9781316649794 , Digital Systems:Principles&Design(Anna) Rajkamal 9789332535916 , Principles Of Cognitive Radio Vincent 9781107439900 , Digital Signal Processing 4Ed Proakis 9788131710005 , Op Amps And Linear Integrated Circuits Gayakwad 9789353949037 , Microwave And Radar Engineering Rao 9788131799444 , Introduction To Pspice Using Orcad For Circuits And Electronics Rashid 9789332555174 , Basic Electronics Saha 9781316632932 , Linear Integrated Circuits Salivahanan 9789353163808 , Principles Of Electronic Communication Orient 9789386235107 , Optoelectronic Devices And Optical Fiber Communication Chakrabarti 9789354667947 , Introduction To Vlsi Design Flow Sneh Saurabh 9781009200813 , Antennas And Wave Propagation Kraus 9789352606184 , Network Analysis Revised 3Ed Van Valkenburg/ Rathode 9789353433123 , Communication Systems : Analog And Digital, 3Rd Singh 9781259004605 , Internet Of Things The : How Smart Tvs Sm Miller 9789332552456 , Microwave Devices & Circuits 3Ed Liao 9788177583533 , Fundamentals Of Mobile Computing 2Ed Pattnaik Bks534717 , 5G Mobile And Wireless Communication Technology Pauline Cullen 9781009590921 , The Intel Microprocessors : 8086/8088,80186/80188,80286,80386,80486,Pentium, Pentium Pro Processor, Pentium Ii - 8Ed Brey 9788131726228 , Circuits Analysis Theory And Practic Robbins 9788131519028 , Medical Instrumentation 5Ed : Application And Design : An Indian Adaptation Webster 9789354249150 , Microwave Engineering, An Indian Adaptation Theory And Techniques Pozar 9789388991087 , Wireless Communications 2Ed Molisch 9789354248795 , Controll System Eng. 8/Ed Norman 9789357463980 , Signals, Systems, And Transforms, 4/E Phillips 9789332518490 , Antenna Theory And Applications 4Ed Balanis 9789354248474 , Gate 2025 Electronics And Communication Eng.Guide Gkp 9789356819306 , Introduction To Analog And Digital Communication 2Ed Haykin 9789354644337 , Digital Image Processing Gonzalez 9789353062989 , Power Electronics (An Indian Adaption) Ned Mohan 9789354640278 , Dorfs Introduction To Electric Circuits Wiley India Edition Richard 9788126573493 , Electronic Devices 10Ed Robert Floyd 9789354493935 , Communication Systems 5Ed Haykin 9789354640896 , Modern Control Engineering Ogata 9789332550162 , Electric Circuits With Mt Kang 9789386650344 , The Intel Microprocessors : 8086/8088,80186/80188,80286,80386,80486,Pentium, Pentium Pro Processor, Pentium Ii - 8Ed Brey 9788131726228 , Modern Digital Electronics-5Th Edtion Jain 9789355321770 , Analog And Digital Electronics Roth 9789353502355 , Introduction To Communication Systems Madhow 9781316608241 , Voip Handbook Application Technologies Ahson 9781420070200 , Embedded Systems Handbook 2Ed Network Embedded System Zurawski Bks331227 , Matlab: An Introduction With Applications 6Ed Amos Gilat 9789357462174 , Fiber Optic Communication Systems 5Ed Agrawal 9789357461245 , Crc Handbook Of Modern Telecommunications 2Ed Morreale Bks331221 , Mathematical Aspects Of Signal Processing Sircar 9781107175174 , Rf And Microwave Semiconductior Device Handbook Golio 9780849315626 , Electronic Systems Maintenance Handbook, Second Edi Whitaker Bks322864 , The 8051 Microcontroller Ayala 9788131502006 , Digital Systems Design Using Vhdl W/ Roth 9788131518304 , Fundamentals Of Engineering Electromagnetics Cheng 9789332535138 , Basic Electronics-2Ed Kothari 9789352606467 , Power Electronics Essentials & Applications Umanand 9788126519453 , An In Depth Guide To Mobile Device Forensics Chuck Easttom 9781032785905 , Automotive Embedded Systems Handbook Navet Bks335190 , Wavelet Analysis With Applications To Image Process Prasad 9780849331695 , Primer On Wavelets And Their Scintific Applications Walker 9781032963617 , Face Detectin And Recognition: Theory And Practice Datta A.K. 9781032728964 , Fiber Optics & Optoelectronics Khare 9780195669305 , Mobile Cellular Telecomm 2E Lee 9780070635999 , Cmos Vlsi Design : A Circuits And Systems Perspective, 3Ed Weste 9788131762653 , Antennas Blake 9789380381268 , Mobile Communications, 2Ed Schiller 9788131724262 , Introduction To Wireless Systems Black 9788131726389 , Ad Hoc And Wilreless Sensor Network Athawale 9789356066137 , Linear Integrated Circuits Sathishkumar Bks476847 , Linear Integrated Circuits Dhanasekar Bks638493 , Embedded And Real Time Systems Ramprabu Bks476848 , Transmission Lines And Rf Systems Shanmugaraja Sivakumar Bks490771 , Transmission And Distribution Gayathri Bks476751 , Wireless Communication Santhosh Krishna Bks638491 , Digital System Design Edwindhas Bks638462 , Power Quality & Distributed Generation Jayaprakash 9788184876987 , Digital Signal Processing Antoniou 9780070636330 , Power System Engineering 3 Ed Kothari 9789353165116 , Digital Integrated Circuit 2/Ed Rabeay 9789332573925 , Principles Of Electronic Materials Kasap 9789390113866 , Digital Logic Circuits With Vhdl And Verilog Programs Nagoor Kani 9789354669606 , Principles Of Electronic Materials Kasap 9789390113866 , Wireless Communications : Principles Rappaport 9789356066212 , Communication Networks Fundamentals Leon 9780070595019 , Interoperability In Iot For Smart Systems Roy M. 9781032728100 , Basic Elec & Linear Circuits Bhargava 9781259006463 , Brain Computer Interface Eeg Signal Processing Panigrahi 9781032851181 , Learning Basics And Electronic Science Through Mcqs Priya 9789394639249 , Fundamentals Of Logic Design Roth 9789360535650 , Engineering Circuit Analysis 10E/D Hayt 9789364441094 , Programmable Logic Controllers 6Th Ed Petruzella 9789355325860 , Modern Wireless Communication Haykin 9788131704431 , Signals And Systems 5Ed Ramesh Babu Bks505218 , Digital Signal Processing Ramesh Babu Bks503977 , Digital Image Processing 2Ed Sridhar Bks643706 , Digital Logic Circuits With Vhdl And Verilog Programs Nagoor Kani 9789354669606 , Wireless Communications : Principles Rappaport 9789356066212 , Digital Integrated Circuit 2/Ed Rabeay 9789332573925 , Brain Computer Interface Eeg Signal Processing Panigrahi 9781032851181 , Internet Of Nanothings And Wireless Body Area Networks Fadi 9781032599144 , Phyiscs For Electronics & Information Science Palanisamy 9789386923134 , Vlsi Design Sathyah Bks665018 , Basic Elec & Linear Circuits Bhargava 9781259006463 , Communication Networks Fundamentals Leon 9780070595019 , Linear Integrated Circuits Salivahanan 9789353160487 , Wireless Communications : Principles Rappaport 9789356066212 , Linear Integrated Circuits Salivahanan 9789353160487 , Digital Logic & Computer Design Mano 9789332542525 , Digital Electronics Bignell 9788131520710 , Design Of Analog Cmos Integrated Circuit-2Ed Razavi 9789387067844 , Fundamentals Of Logic Design Roth 9789360535650 , Engineering Circuit Analysis 10E/D Hayt 9789364441094 , Digital Electronics Bignell 9788131520710 , Design Of Analog Cmos Integrated Circuit-2Ed Razavi 9789387067844 , Applied Machine Learning Gopal 9789354601590 , Essentials Of Digital Signal Process Using Matlab Ingle/Proakis 9788131517727 , Arm System On Chip Architecture Furber 9789332555570 , Smart Grid In Iot Enabled Spaces Fadi Ai Turjman 9781032598543 , Power Plant Engineering Nag 9789354600050 , Mathematical Analysis A Straightforward Binmore 9781107526235 , Algebra 2Nd Edition Michael Artin 9789353432751 , Discrete Mathematics Dhami 9780199452798 , Statistics And Numerical Methods 10Ed Vijayakumari 9789356062733 , Algebra, 3Ed Sahai 9788173198250 , Algebraic Topology M J Greenberg , J R Harper 9780367475604 , Algebra, 4Ed Sahai 9788184876208 , Concept Of Modern Algebra Pandey 9788184877069 , Friendly Introduction To Number Theory Silverman 9789353433079 , Elementary Differential Equations 8Ed Richard 9789332571617 , Introduction To Graph Theory West 9789332549654 , Linear Algebra Ubaidullah 9789391549893 , Higher Algebra Barnard 9789385923326 , Sequences And Series Arumugam 9789388005128 , Modern Analysis Arumugam 9789388005111 , Intorduction Topology And Modern Analysis Simmons 9789387465916 , Higher Algebra Hall Knight 9788174731043 , Analytical Geometry Veerarajan 9789388005142 , Transforms And Partial Diffrential Equations 3Rd Ed Muthucumaraswamy 9789391549473 , Multilevel Analysis: Techniques And Applications 3/E Hox 9781032938035 , Thomas Calculus 15Ed Hass 9788119896608 , Calculus Vil I 2Ed ( An Indian Adaptation) Apostol 9789354642630 , Calculus 10Ed Saturmino Salas Einar Hille Ga 9789390421961 , Introduction To Linear Regresion Analysis, 6Ed Montgomery 9789357461283 , Matrices Advanced Calculus & Complex Stewart 9789360534509 , Operations Research Mote 9788126556380 , Topology 2Ed James Munkres 9789353432775 , Linear Algebra 5Ed Friedberg 9789390168132 , Multivariate Calculus Joshi Bks498996 , Mathematical Analysis 6Ed Malik Bks413195 , Stochastic Processes 5Ed Medhi 9789389802245 , Human Resource Management Aswathappa 9789355323675 , The Elements Of Complex Analysis 3Ed Choudhary 9789388818780 , Probability And Statistics For Engineering Devore 9789353506247 , Operations Research Panneerselvam 9789354437892 , The Elements Of Complex Analysis 3Ed Choudhary 9789388818780 , Optics 8Ed Ghatak 9789355328595 , Outline Of Beginning Physics Schaum 9789389538984 , Outline Of Astronomy Schaum 9789389538939 , Introductory Nuclear Physics 3/Ed Krane 9789354640834 , Physics Vol 2 5Ed David Halliday Resnick 9789354640438 , Physics For Scientists And Engineers Serway 9789355739223 , Non Conventional Energy Source Math 9789388005081 , Nuclear Physics Theory And Experiments 3Ed Roy 9788122449884 , Gravitation : Foundations And Frontiers (South Asian Edition) Padmanabhan 9780521178761 , Electricity And Magnetism Murugeshan 9789352837342 , Introductory Nuclear Physics Wong 9788126546060 , Modern Physics Murugeshan Bks367126 , Introduction To Electrodynamics South Asia Ed - 4/Ed David J. Griffiths 9781108822909 , Theoretical Astrophysics Vol 2 Padmanabhan 9781107400603 , Heat Thermodynamics And Statistical Physics Lal Subramanian Bks460942 , Classical Dynamic Of Particles Thornton 9788131518472 , Materials For Engineers And Technicians 7Ed Bolton 9781032973722 , Statistical Mechanics 2Ed (An Indian Adaption) Kerson Huang 9789354247736 , Atomic And Molecular Spectroscopy Rita Kakkar 9781108413206 , Laser Fundamentals Silfvast 9780521138475 , Engineering Chemistry 2E : Fundamentals And Applications Shikha Agarwal 9781108724449 , Organic Name Reations Sanjay Bari 9789389354737 , Basics Of Environmental Science Khosla 9788184874013 , Environmental Chemistry Singhu 9788122427318 , Biomaterials Principles And Applications Joon Park 9781032934167 , Organic Reaction Mechanisms Ahluwalia Bks366263 , Organic Synthesis Concepts And Methods 3Ed Pb 2014 Jurgen Hinri 9788126547227 , Engineering Chemistry Palanna 9789352605774 , Engineering Chemistry 2Nd Ed Wiley 9788126543205 , A Textbook Of Engineering Chemistry Dara Bks561640 , Engineering Chemistry Vairam & Kalyani 9788126543342 , Chemical Applications Of Group Theory Albert Cotton 9788194726364 , Environmental Science And Engineering Yuganath 9788183717014 , Environmental Science Isv 8Th/Ed Botkin, Killer 9788126534142 , Chemical Reaction Engineering 3Ed (An Indian Adaptation) Octave Levenspiel 9789354244605 , Outline Of Thermodynamics Schaum 9789389538540 , Textbook Of Chemical Engineering Thermodynamics Narayanan 9788120347472 , Communication Skills, 3Ed Sanjay Kumar 9789354978555 , English For Science & Technology-I Chellammal 9781009224796 , English For Science & Technology-Ii Francis 9781009251181 , Effective Technical Communication Rizvi 9789352605781 , Research Methodology Vinod 9789352863518 , Placement Interviews Skills For Success Anandamurugan 9780070700956 , Prowess Orient 9789354421242 , Research Methodology Panneerselvam 9788120349469 , Academic Writing A Handbook For Students Stephen Bailey 9781138615533 , Design Thinking In Technical Communication Jason C K Tham 9781041004356 , Principles Of Scientific And Technical Mohapatra 9789355327482 , Critical Thinking Idea Innovation And Creativity Richard H Mccuen 9781041000846 , Literature For Language Skills 2Ed Mahanand 9789388005470 , Academic Writing P.B Ajay Semalty 9789390211739 , Teaching English Through Folktales Mahanand 9789391549077 , An Introduction To Literary Studies Mario Klarer 9781032785974 , Heritage Of Tamils Muthuramalingam 9789391549718 , A Short History Of English Literature Saintsbury 9788174733054 , The English Language Wrenn 9788174733368 , An Introduction To The Study Of English Litetrature Hudson 9788174731197 , Rabindranath Tagores Ideational Challenges Bidyut Chakrabarty 9789356400122 , English Literature Long Bks476291 , Test Of Reasoning 7Th Edn Thorpe 9789389811513 , Science And Technology 8Ed Agarahri Ravi 9789355326324 , Excel Reasoning Arun Sharma 9789355329455 , Aptipedia Aptitude Encyclopedia 2 Ed Wiley 9788126569502 , Excel Quantitative Apititude Arun Sharma 9789355327970 , Verbal Ability And Reasoning For Competitive Examinations Anand Lalit Singh 9788126554294 , Intermediate Engligh Grammer With Answers, 2Ed Murphy 9788185618517 , Design Thinking Teun Den Dekker 9781032786018 , Spotting Errors Lakshminarayanan Bks670723
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 3
25.
Defence #11281747 Technical Bid
Tender For Provision Of Defi Md Accommodation At Kota Mil Stn; 1 Lump sum price worked out by the contractor for BUILDING WORKSas listed in Schedule ‘A’ Part-I representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES 2 Lump sum price worked out by the contractor for INTERNAL WATER SUPPLY as listed in Schedule ‘A’ Part-II representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES 3 Lump sum price worked out by the contractor for INTERNAL ELECTRIFICATIONas listed in Schedule ‘A’ Part-III representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES 4 Lump sum price worked out by the contractor for ROAD, PATH, CULVERT AND HARD STANDINGas listed in Schedule ‘A’ Part-IV representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES 5 Lump sum price worked out by the contractor for SEWAGE DISPOSALas listed in Schedule ‘A’ Part-V representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES 6 Lump sum price worked out by the contractor for AREA DRAINAGE as listed in Schedule ‘A’ Part-VI representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES 7 Lump sum price worked out by the contractor for FENCINGas listed in Schedule ‘A’ Part-VII representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES 8 Lump sum price worked out by the contractor for EXTERNAL WATER SUPPLYas listed in Schedule ‘A’ Part-VIII representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceof prepriced by the MES 9 Lump sum price worked out by the contractor for EXTERNAL ELECTRIFICATIONas listed in Schedule ‘A’ Part-IX representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceof prepriced by the MES 10 Lump sum price worked out by the contractor for LIGHTING PROTECTION as listed in Schedule ‘A’ Part-X representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES 11 Lump sum price worked out by the contractor for FIRE FIGHTINGas listed in Schedule ‘A’ Part-XI representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceof prepriced by the MES 12 Lump sum price worked out by the contractor for LIFT WORKas listed in Schedule ‘A’ Part-XII representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceof prepriced by the MES 13 Lump sum price worked out by the contractor for HOT WATER SUPPLYas listed in Schedule ‘A’ Part-XIII representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceof prepriced by the MES 14 Lump sum price worked out by the contractor for DG SETSas listed in Schedule ‘A’ Part-XIV representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceof prepriced by the MES 15 Lump sum price worked out by the contractor for SITE CLEARANCE, SITE DEVELOPMENTAND EARTH WORKas listed in Schedule ‘A’ Part-XV representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES 16 Sch A Part-XVI MISC ITEMS (TO BE QUOTED BY CONTRACTOR) Notes:(i) This schedule is not pre-priced by MES and the pre-priced rate indicated as Rs 0.00 under column 5 signifies this fact only. (ii) Excavation and earth work except for the items which categorically includes for same shall be measured and paid separately under SCH A PART-XVSITE CLEARANCE, SITE DEVELOPMENTAND EARTH WORK schedule). 17 INTERNAL WATER SUPPLYS&F for 15mm dia sink mixer (wall mounted) with 150mm long swivel spout,connecting legs and wall flangerswith complete accessories etc complete all as specified and directed.Make: CERA Cat Part No F2014511 / Hindware Cat Part No F690058 / Parryware Cat Part No G3335A1 or equivalent make as mentioned in Appx B. 18 S&F for 15mm dia single lever center hole basin mixerwith complete accessories etc complete all as specified and directed.Make: CERA Cat Part No F1015451 / Hindware Cat Part No F690012 / Parryware Cat Part No G4863A1 or equivalent make as mentioned in Appx B. 19 S&F for 15mm dia wall mixture with bend pipe for overhead showerwith complete accessories etc complete all as specified and directed.Make: CERA Cat Part No F2002401 / Hindware Cat Part No F330020 / Parryware Cat Part No G3316A1 or equivalent make as mentioned in Appx B. 20 INTERNAL ELECTRIFICATIONS&F ofmodular type 3 pin 20 A socket with SP MCB, conforming to IS 1293: 2005as specified in IS 732: 2019 etc complete all as specified and directed 21 S&F for modular type 1 module RJ-11 telephone socket with shutter etc complete all as specified and directed 22 S&F for modular type 1 module co-axial type TV socket etc complete all as specified and directed 23 S & F for 16 A, 230 V, 50 Hz, 2P MCB (B curve) MCB conforming to IS/IEC 60898-1-2002, having breaking capacity Icn = 10 kA, sliding bottom clamp, colour coded on/off indication on dolly, bi-connect IP 20 protected lower terminals and sliding shutters,IS 732: 2019 etc complete all as specified and directed 24 S & F for 25 A, 230 V, 50 Hz, 2P MCB (B curve) MCB conforming to IS/IEC 60898-1-2002, having breaking capacity Icn = 10 kA, sliding bottom clamp, colour coded on/off indication on dolly, bi-connect IP 20 protected lower terminals and sliding shutters,IS 732: 2019 etc complete all as specified and directed 25 S & F for 32 A, 230 V, 50 Hz, 2P MCB (B curve) MCB conforming to IS/IEC 60898-1-2002, having breaking capacity Icn = 10 kA, sliding bottom clamp, colour coded on/off indication on dolly, bi-connect IP 20 protected lower terminals and sliding shutters,IS 732: 2019 etc complete all as specified and directed 26 S & F for 40 A, 230 V, 50 Hz, 2P MCB (B curve) MCB conforming to IS/IEC 60898-1-2002, having breaking capacity Icn = 10 kA, sliding bottom clamp, colour coded on/off indication on dolly, bi-connect IP 20 protected lower terminals and sliding shutters,IS 732: 2019 etc complete all as specified and directed 27 S&F forSingle Phase Dual Source Pre Paid Meter, Class 1.0, RS485,10/60A Direct,with followingspecification as under : (i) Communication options:, RS485 and RF(ii)Three in one option:Integrate gas & waterupto 4 DI(iii) Programmable tariff for EB, DG and DI for automatic reduction of balance even server is offline(iv) Configurable Holidays,Happy hours to avoidload switching on Holidays/Night(v) Alarm notifications for low credit balance(vi) Eliminate tenantdisputes, meter tampering & manualtariff reading errors 28 S&F forThree Phase Dual Source Pre Paid Meter, Class 1.0, RS485, 5A CT operated,with followingspecification as under : (i) Communication options:, RS485 and RF(ii)Three in one option:Integrate gas & waterupto 4 DI(iii) Programmable tariff for EB, DG and DI for automatic reduction of balance even server is offline(iv) Configurable Holidays,Happy hours to avoidload switching on Holidays/Night(v) Alarm notifications for low credit balance(vi) Eliminate tenantdisputes, meter tampering & manualtariff reading errors 29 S&F of Sheet metal enclosure distribution board VTPN4 way, 415 voltdouble door powder coated, protection class IP-54 isolated neutral bar, mechanical impact strength IK 09 suitable for mounting MCB & MCCB DBs confirming to IS - 13032, IS-8623, BS EN60898 with min 200 Amp rating copper bus bar and grouting, fixing on wall with nut bolts washers proper with PCC works complete all as specified and directed 30 S&F of Sheet metal enclosure distribution board VTPN6 way, 415 voltdouble door powder coated, protection class IP-54 isolated neutral bar, mechanical impact strength IK 09 suitable for mounting MCB & MCCB DBs confirming to IS - 13032, IS-8623, BS EN60898 with min 200 Amp rating copper bus bar and grouting, fixing on wall with nut bolts washers proper with PCC works complete all as specified and directed 31 S&F of 160A, 4 pole moulded case circuit breaker (MCCB) with thermal magnetic trip unit (TMD), compression lug connectors, protection against overloads (Ir adjustable from 0.7- 1 X In), protection against short circuits (Isd adjustable from 5- 10 X Ir), inbuilt encapsulated double break roto active type instanteneous protection, earth fault leakage protection, etc. having Ics = 100% = Icu = 16 kA as per IEC 60947-2 and suitable for 3-Phase, 415 V, 50 Hz electric supply etc complete all as specified and directed by engineer-in-charge. 32 S&F for 12W LED Downlight having Luminous efficacy of > 100, input voltage range 140-270 V, input frequency 50-60 Hz etc complete all as specified and directed . 33 S&F for LED light fitting with high 10 watt 220 V AC decorative wall type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size etc complete all as specified and directed . 34 S&F for 10W LED bulk head light having Luminous efficacy of > 100, input voltage range 140-270 V, input frequency 50-60 Hz etc complete all as specified and directed. 35 Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 600 mm sweep. Min air delivery 115 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) etc complete all as specified and directed by engineer-in-charge. 36 Supply and fix Wall Mounting Fan, steel body AC single Phase, 230V,With Sweep Size, 200mm ; Motor Speed 84CMM, 3 blades, and frame and louvers etc complete all as specified and directed by engineer-in-charge. 37 Supply, installation, testing and commissioning of factory made, indoor cubical compartmental type BUILDING PANEL (TTA) of suitable size for short circuit, temperature rise, protective earth short circuit test and dielectric tests of required ratings, conforming to IEC 61439-1 & 2 and IEC 61641, having both sides openable with hinged double doors and locking arrangement, IP 42 protection made out of 2.0 mm thick mild steel CRCA sheet, supported and fixed on structural frame of angle iron of suitable size, including earthing stud, labelling, painting to all internal & external exposed steel surfaces with powder coating paint (7 tank process), duly fixed in ground with PCC foundation (1:2:4) type B1, with danger notice plate of 1.6 mm thick mild steel vitreous enameled (white) with letters, figures and conventional skull and bones in signal red colour suitable for 3- Phase, 4 Wire system, 500 V grade with necessary wiring, PVC sheathed stranded copper conductor of appropriate length and size, including fixing lugs, bolts, screws, etc. complete as specified and directed by engineer-in-charge.The BUILDING PANEL shall comprise of the following:(A) Bus bar Chamber(i) 01 Set (3L + N) of copper busbar of rated capacity 400A, covered with PVC insulated sleeves including insulator, nuts, bolts, etc. with complete connections. 38 (B) Incoming:- (i)320A, 415 V, Ics = 100% Icu = 16 kA, 50 Hz 4P MCCB, conforming to IEC 60947-2, having microprocessor based trip unit, adjustable overload setting (0.7 - 1 X In), adjustable short-circuit setting (5 - 10 X Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (ready, overload and pre-alarm & overload)- 01 No.(ii) Cl 1.0 multi-function meter capable of measuring V, A, F, PF, W/VA, Wh/VAh, Runhrs. Onhrs & interupts- 01 No.(iii) LED phase indicators (Red, Yellow, Blue)- 01 Set 39 (C) Outgoing:-(i)40A, 415 V, Ics = 100% Icu = 16 kA, 50 Hz 4P MCCB, conforming to IEC 60947-2, havingtrip unit, adjustable overload setting (0.7 - 1 X In), adjustable short-circuit setting (5 - 10 X Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (ready, overload and pre-alarm & overload)- 08 Nos(ii) LED phase indicators (Red, Yellow, Blue)- 08 Sets 40 SEWAGE DISPOSALS&F for DWCPE (SN8) 180mm outer dia and 163 inner dia of pipe for depth 0.70mm to 1.65m, laid on 150 mm thick bed (1:4:8)with excavation in any type of soil including manholes/drop manhole of standard sizemade of brick mosonary /RCC/Precast RCC with SFRC ventilating cover and frame,includes all items and activities to execute and make sewer line functionaletc complete all as specified and directed. 41 S&F for DWCPE (SN8) 200mm outer dia and 175 inner dia of pipe for depth 0.70mm to 1.65m, laid on 150 mm thick bed (1:4:8) with excavation in any type of soil including manholes/drop manhole of standard sizemade of brick mosonary /RCC/Precast RCC with SFRC ventilating cover and frame,includes all items and activities to execute and make sewer line functionaletc complete all as specified and directed. 42 S&F for DWCPE (SN8) 300mm outer dia and 260 inner dia of pipe for depth 1.65mm to 2.3m, laid on 150 mm thick bed (1:4:8) with excavation in any type of soil including manholes/drop manhole of standard sizemade of brick mosonary /RCC/Precast RCC with SFRC ventilating cover and frame,includes all items and activities to execute and make sewer line functionaletc complete all as specified and directed. 43 Supply, lay, commissioning, jointing and testing ofcentrifugally cast (spun) ductile iron pipes of 150mm bore class K-7 with spigot and socket ends conforming to IS 8329/2000, IS: 12288 : 1987 code of practice for laying in trenches complete all as specified and directed.Note: The rate quoted by contractor are inclusive of all type of Joints. 44 S&F forNonclog submersible (sewage disposal), pump set, electric driven 415 Volts 3 Phase 50 Hz, supply comprising of pump with cast iron impellors, submersible motor of suitable capacity, coupling, at discharge 3360 to 480 LPM and minimum discharge should be less than 480 LPM at minimum head 14 m.including chain pully block of two MT capacity 01 Noandsuitable arrangement for hanging the motor through chain of requirement of delivery of pump connected to main pipe line by suitabe HDPE pipe of size 150mm Dia for required length with necessary connection etc all as specified and as directed. 45 Supply,installing, testingand commissioningout door type LT feeder piller box of suitable size 750X750X450 mm, pedestal mounted, CPRI type test totally enclosed, dust and vermin proof, double leaf shutter in front and single leaf shutter in rear side made of 3.15 mm thick CRCA sheet, framing with 50 x50 x 6 mm thick MS angle iron and legs of size 0.5m long . duly fabricated and having proper locking arrangement in both front and rear door with 4 side slanting roof duly projected and paintedto both internal and External surfaces with powder coating paint in heatprocess of sheet and suitable for 415 volts, 50 Hz, 3 phase 4 wire system and comprising with and includingfollowing accessories and mounted on PCC Platform made out of100 mm thick PCC (1:3:6),0.45 Mtr all round the panel board etc complete with the following items :- 46 Incoming:- (i) Copper bus bar made up of copper strip100 amps duly mounted on bakelite insulatorssleevings of standard colour code - 01 Set. (04 No strips for Phases & Neutral)(ii) MCCB TPN 415 Volts,63 Amps, 50 Hz, breaking capacity 25 KA with fixed thermal & magnetic setting ( For Incomming ) - 01 No.Outgoing:-(i) MCB TP 415 volts 32 Amps, breaking capacity 16 KA with fixed thermal & magnetic setting ( For FPB2 ) - 03 Nos(2 nos for pump 1 nos for spare). (ii) FASD Starter for 15 HP Motor with single phase preventer, OLP and dry run protector- 02 Nos 47 (iii) Analogue type modular volt meterof range 0-500 volts -01 No(iv)Volt meter selector switch-01 No.(v) Analogue typeAmmeter of range 0-200 Amp-01 No(vi) Ammeter selector switch-01 No(set of three)(vii) Indicator lamp with integral circuit (230/240 volt) and cluster LED (Red, Orange, Blue) - 01 set(viii) CT 200/5 Amps - 3 Nos 48 Supply and FixingDI/CI special fittings of any size,type,radius angle,tapers increasing decreasing sockets,tees,tail piece and collars etc complete upto 200 mm dia etc complete all as specified and directed. 49 S&F forPVC insulated and sheathed 1100 volts grade flat type submersible 06 sqmm cable three core multi stranded conductor etc complete all as specified and directed . 50 M&L for Making drill hole by trenchless technologyof suitable size under road for laying pipe line of size150mm bore at 1 metre depth from the road level etc complete all as specified and directed.Note :- Drill hole (trenchless) shall be done without disturbing top surfaces of road by appropriate machine. 51 M&L for steel gate 5.45 m wide and 2.70 m height with RCC pillar including excavation in any type of soil, plastering, painting, etc complete all as specified and shown in TD/2008/101 sheet No 1/3 to 3/3 52 EXTERNAL WATER SUPPLY Supply, lay, commissioning, jointing and testing ofcentrifugally cast (spun) ductile iron pipes of 100mm bore class K-9 with spigot and socket ends conforming to IS 8329/2000, IS: 12288 : 1987 code of practice for laying in trenches complete all as specified and directed.Note: The rate quoted by contractor are inclusive of all type of Joints. 53 Supply, lay, commissioning, jointing and testing ofcentrifugally cast (spun) ductile iron pipes of 150mm bore class K-9 IS: 12288 : 1987 code of practice for laying in trenches complete all as specified and directed.Note: The rate quoted by contractor are inclusive of all type of Joints. 54 Supply and FixingDI/CI special fittings of any size,type,radius angle,tapers increasing decreasing sockets,tees,tail piece and collars etc complete upto 200 mm dia etc complete all as specified and directed. 55 Supply and fix CI foot valve with leather washer, ofsize 100 mm , lift and swing, single door, IS 4038 marked one with each pump suction line complete all as specified and directed. 56 M&L for construction of valve chamber of brick masonry from the top of surface with MS covers 3.15 mm thick and 40x40x6 mm MS angle with hinges for locking arrangement including excavation and earth works PCC (1:3:6) type C2 for foundation PCC bed/coping in cement concrete (1:2:4) type B1, plastering in CM 1:3 painting with two coats of synthetic enamel paint over a coat of red oxide primerfor the size of chamber 1200 mm x 1200 mm x 1200 mm (internal dimention) complete all as specified and directed. 57 Supply, install,commissioning and testing of Horizontal split case cetrifugal pump set 1450 RPM having an output of minimum 1100 LPM at a head of 45 mtr coupled to 3 phase 415 volt squirel case induction motor of adequate capacity complete all as ditected by Engr-in-charge with and including following :-(a) Necessary cable for interconnection between starter panel & pump set with 1100 volt rated copperinsulated unarmoured cable of minium 10 sqmm 3 core cable(b) Single phase preventer (current sensing type)(c) Necessary light grade GI pipe protection for cabling from pump set to LT panel.(d) Bourden pressure gauge.(e) MS pipe flanged type class B of size 100 mm bore upto foot valve from suction end of pump.(f) PCC foundation in type B-2, 1:2:4 using 20mm graded aggregate, 20cm above ground level and 30cm below grond level including grouting of eye bolts nut etc. for pump set of adequate size or as per manufacturers recommendations.Note: All other items/material requiredfor fixing pumpset shall be included in cost quoted.(ii) Foundation drawing shall be approved by GE/ Eng-In- Charge before fixing the pump set. 58 Supply, installations, testing and commissioning of factory made LT Indoor cubical typepanel boardhaving 150 Amp rated copper bus bar with neoprene rubber gasket and locking arrangement, dust,weather and verminproof , free standing, floor mounting type self ventilation with wire mesh,totally enclosed busbar chamber fully comparted type, front openable hinged independent door for each compartment with locking arrangement and common openable hinged door from rear side of suitable size made out of 2mm thick CRCA sheet duly painted with seven tank process,415 V,TPN,50Hz both side properly welded MS angular supported with chanel frame of size 50mm,at all vertical corner grouted in PCC 1:3:6 (Type-C1 using 20mm graded stone aggregate) and connecting the incomming/outgoing feeder by providing brass cable glands and Lugs complete all as specified and directed comprising of followings accessories:- 59 Incoming:- (i) MCCB 4 Pole 100 amps ,415 Volt of breaking capacity not less than 36 KA (Ics=100 % of Icu) with adjustable thermal Setting-01 No.Outgoing:-(i)MCCB 3 Pole 63 amps ,415 Volt of breaking capacity not less than36 KA (Ics=100 % of Icu) with adjustable thermal Setting - 02 Nos (ii) Single phase preventor -02 Nos(iii) On load Change over switch 4 pole of current raring 63 A (open execution type) - 01 No(iv)MCB SPN 10 Amp C curve, 10 KA capacity - 01 No(v) fully automatic Star-delta starter 15 HP or recommended by manufacturer of motor -02 Nos(vi) LED Indicator lamp (R,Y,B)- Set of Three.(vii) Multifunctional meterDigital type showing V,A,F,Pf,KW,KWH inbuilt selector switch with CT coiles for three phase -0 1No. 60 M&L for construction of header of ERW pipe having size dia 300 mm and length 2.5 m with two inlet connection of size 100 mm & three otlet connection having size 150 mm complete monting on RCC base/plinth etc complete all as specified and as directed by Engr-in-charge. 61 EXTERNAL ELECTRIFICATIONBoring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine for laying under ground pipe upto 100mm dia complete all as specified and directed.Note :- GI pipe shall be measured and paid separately. 62 Taking out existing HT XLPE U/G cables, 11000 V grade from trenches/ducts/ poles etc of size 120 Sq. mm 3 Core etccomplete all as specified and directed. 63 Dismantling and taking down existing transformer mounted on four pole structure and shifting to nearest suitable location including its fixing on newly constructed platform and making all connection, testing as per requirementetccomplete all as specified and directed. 64 Dismantling and taking down existing 4-pole structure etccomplete all as specified and directed. 65 Dismantling and taking down existing 03 Nos of LT Panels, refixing at specified locationincluding connecting etc complete all specified and directed. 66 Taking out existing LT XLPE U/G cables, 1100 V grade from trenches/ducts/ poles etc of size 240 Sq. mm 3.5 Core etc complete all as specified and directed. 67 Taking out existing LT XLPE U/G cables, 1100 V grade from trenches/ducts/ poles etc of size 185 Sq. mm 3.5 Core etc complete all as specified and directed. 68 Taking out existing LT XLPE U/G cables, 1100 V grade from trenches/ducts/ poles etc of size upto 95 Sq. mm 3.5 Core etc complete all as specified and directed.Note For item No. 57 to 63 :- The old material obtained from site shall be deposite by contractor in MES store yard without any extra cost as directed by GE. 69 M&L for construction of plateform of size 3500 x 3500 x 1200mm with brick construction in cement mortar 1:4 PCC (M-10 nominal mix) in foundation, 100mm thick RCC M-25 grade slab, with 8mm MS TMT bars 120mm c/c on bothway, brick masonary steps on one side XPM Jali fixed on angle iron 40x 40x6 mm post upto height of 8 feet above ground level and openable gate with locking arrangment including making provision for entry and exit of HT/LT cables and steps made to access to the top of plateform including plastering to bricks masonary complete including painting with 2 coats of whitewash on plastered surface and painting steel surface with 2 coats of red oxide primeretc complete all as specified and directed. 70 Supply & fix HT 11 KV, outdoor type gang operated air-break switch suitable for horizontal or vertical mounting rotating type complee with drop out fuse having 12 insulators of rating upto 200 Amps etc complete all as specified and directed. 71 Supply and fixing lightning arrestor HT 11 KV, 10 KA station class etc complete all as specified and directed. 72 Supply & errect 2 pole structure on 11 mtr PCC pole consisting of pole with anti-climbing device, PCC foundation & cross arms (Bracings) etc for one incoming and one out going. etc complete all as specified and directed. 73 Supply, installation, testing & commissioning of package type/unitised 11kV / 433 V Outdoor sub-station (CSS) ,315KVA made from G. I. enclosure complete as required conforming to IEC 62271-202 only and relevant IS specifications including K-10 Temperature Class as applicable for the rating, Internal Arc of 21 KA/1 Sec. IAC AB on 1:2:4 (1 cement :2 cores and : 4 Graded stone aggrregate of 40 mm nominal size) PCC foundation of suitable size extending 500 mm all around the outdoor enclosure and 1000 mm height (above ground level) complete with suitable sizes of GI Pipes for incoming/outgoing cables/earthing strips etc. and consisting of following complete as required. Angle iron frame of size 40x40x5mm NS all along the corner of the foundation CSS shall be from OEMs only . Licensed System Integrators of approved OEM are not allowed to supply .Package substation will have the following equipment :- 74 HT SWITCHGEAR11kV 630Amps 21KA/3 sec. Non-Extensible Ring Main Unit Compact switchgear consisting of1 no. fixed motorized Vacuum Circuit Breaker Moduleand 2 nos. fixed morotized Load break switch module in SF6 insulated stainless steel enclosure with series trip, self powered microprocessor based numerical over current and earth fault relay protection. HT RMU shall preferably have site replaceable bushings to have very less downtime in the event of bushing breakage and restoration can be done immediately without sending the RMU to OEM Works. Interconnection between HT Switchgear and primary of transformer shall be done through 1C x 3R x 95 sq.mm Aluminium XLPE cable. - 1 No.Vacuum Interrupter,RMU,LT Switchgear and CSS Enciosure shall be of same make to ensure life cycle optimization.(i)Microprocessor based IDMT Relay for Circuit Breakers - Self Powered along with series trip coil (Modbus RS485 complaint)(ii)Capacitive voltage indication fixed type system with LED for all feeder and FPI in all load break switch feeder.(iii)SF6 Gas pressure indicator.(iv)Operating sequence of VCB must be O-0.3Sec-CO-3 Mins-CO(v)Protection CT shall be minimum 40/1A ,2.5VA ,5P10. - 3 Nos 75 (vi)All modules of the RMU shall be suitable for cable termination of 3C x 300 sq.mm Al XLPE Cable, incoming cable termination is included within the scope of work - 1 SetTRANSFORMER315 KVA 11KV/433V DYN-11 Oil type, hermetically sealed energy efficiency level-2 transformer (BEE Star Rated-2) with corrugated wall, without conservator, type of design & Top Bushings for HT & LT with Off load tap switch of rating +5% to -5% @2.5%. Temp Rise - Oil/Winding 40/45 Deg cel. Losses (As per IS-1180 amended up to date)Max Losses @ 50% Load 955W and Max Losses @ 100% Load 2750 KW and Impedance of 4.5% (Subject to IS Tolerance (as per IS1180-2014) The transformer shall be conforming to IS: 2026 and IS: 1180(part-I). amended up to date. (i)01 No. Winding Temperature Indicator with Alarm and trip Contact.LT PANELLVS PANEL 500 AMPS 4 pole Aluminium BUSBAR (100% FOR PHASES AND 100% FOR NEUTRAL) - CURRENT DENSITY OF Aluminum as 1 A/sq.mm. ; LT panel made up of 1.5/2 mm thick CRCA sheet INCOMER CUM OUTGOINGS FROM TRANSFORMER(i)500 Amps 433V 4P 50Hz 50KA Fixed Manual Type Air Circuit Breaker (ACB)(ii) Multifunction meter with Modbus RS485 port & class 0.5 accuracy with Suitable CT. - 1 set 76 (iii)Hard wiring from each equipment inside CSS for scada connectivity (monitoring & control)to be brought to one set of TBs and a space for FRTU to be given. Supply of FRTU is not in scope. (iv)All Civil works such as PCC/RCC foundation, Plateform, Filling trench and pedestal etc as per CSS manufacturers recomandation are included in scope of work.OUTDOOR ENCLOSUREOutdoor type encloser of 1.5 mm (For non load bearing members) & 2.0 mm (For load bearing members) thickness having modular construction of Galvanised Sheet Steel in suitable design for better heat dissipation and providing robust. 77 construction. The Enclosure shall have IP54 degree of protection for HT & LT switchgear compartment & IP 23 degree of protection for transformer compartment. The enclosure exterior shall be painted with epoxy based powder paint (colour RAL 7032). Each compartment will be provided with the door and pad locking arrangement. The design of the enclosure should be type tested for suitablly handling any arcing inside the compartment for providing better safety to the operator. The compartment illumination lamp with door operated switch shall be provided for each compartment.Vacuum Interrupter,RMU,LT Switchgear, Multifunction meterand CSS Enciosure shall be of same make to ensure life cycle optimization. 78 Supply, installation, testing & commissioning of package type/unitised 11kV / 433 V Outdoor sub-station , (CSS) 400KVA made from G. I. enclosure complete as required conforming to IEC 62271-202 only and relevant IS specifications including K-10 Temperature Class as applicable for the rating, Internal Arc of 21 KA/1 Sec. IAC AB on 1:2:4 (1 cement :2 cores and : 4 Graded stone aggrregate of 40 mm nominal size) PCC foundation of suitable size extending 500 mm all around the outdoor enclosure and 1000 mm height (above ground level) complete with suitable sizes of GI Pipes for incoming/outgoing cables/earthing strips etc. and consisting of following complete as required. Angle iron frame of size 40x40x5mm NS all along the corner of the foundation CSS shall be from OEMs only . Licensed System Integrators of approved OEM are not allowed to supply.Package substation will have the following equipment :-HT SWITCHGEAR11kV 630Amps 21KA/3 sec. Non-Extensible Ring Main Unit Compact switchgear consisting of1 no. fixed motorized Vacuum Circuit Breaker Moduleand 2 nos. fixed morotized Load break switch module in SF6 insulated stainless steel enclosure with series trip, self powered microprocessor based numerical over current and earth fault relay protection. HT RMU shall preferably have site replaceable bushings to have very less downtime in the event of bushing breakage and restoration can be done immediately without sending the 79 RMU to OEM Works. Interconnection between HT Switchgear and primary of transformer shall be done through 1C x 3R x 95 sq.mm Aluminium XLPE cable. - 1 No.Vacuum Interrupter,RMU,LT Switchgear and CSS Enciosure shall be of same make to ensure life cycle optimization.(i)Microprocessor based IDMT Relay for Circuit Breakers - Self Powered along with series trip coil (Modbus RS485 complaint)(ii)Capacitive voltage indication fixed type system with LED for all feeder and FPI in all load break switch feeder.(iii)SF6 Gas pressure indicator.(iv)Operating sequence of VCB must be O-0.3Sec-CO-3 Mins-CO(v)Protection CT shall be minimum 40/1A ,2.5VA ,5P10. - 3 Nos.(vi)All modules of the RMU shall be suitable for cable termination of 3C x 300 sq.mm Al XLPE Cable, incoming cable termination is included within the scope of work - 1 Set 80 TRANSFORMER400 KVA 11KV/433V DYN-11 Oil type, hermetically sealed energy efficiency level-2 transformer (BEE Star Rated-2) with corrugated wall, without conservator, type of design & Top Bushings for HT & LT with Off load tap switch of rating +5% to -5% @2.5%. Temp Rise - Oil/Winding 40/45 Deg cel. Losses (As per IS-1180 amended up to date)Max Losses @ 50% Load 1150W and Max Losses @ 100% Load 3330 KW and Impedance of 4.5% (Subject to IS Tolerance (as per IS1180-2014) The transformer shall be confirming to IS: 2026 and IS: 1180(part-I). amended up to date. (i)01 No. Winding Temperature Indicator with Alarm and trip Contact.LT PANELLVS PANEL 630 AMPS 4 pole Aluminium BUSBAR (100% FOR PHASES AND 100% FOR NEUTRAL) - CURRENT DENSITY OF Aluminum as 1 A/sq.mm. ; LT panel made up of 1.5/2 mm thick CRCA sheet INCOMER CUM OUTGOINGS FROM TRANSFORMER(i)630 Amps 433V 4P 50Hz 50KA Fixed Manual Type Air Circuit Breaker (ACB) (ii) Multifunction meter with Modbus RS485 port & class 0.5 accuracy with Suitable CT. - 1 set 81 (iii)Hard wiring from each equipment inside CSS for scada connectivity (monitoring & control)to be brought to one set of TBs and a space for FRTU to be given. Supply of FRTU is not in scope. (iv)All Civil works such as PCC/RCC foundation, Plateform, Filling trench and pedestal etc as per CSS manufacturers recomandation are included in scope of work.OUTDOOR ENCLOSUREOutdoor type encloser of 1.5 mm (For non load bearing members) & 2.0 mm (For load bearing members) thickness having modular construction of Galvanised Sheet Steel in suitable design for better heat dissipation and providing robustconstruction. The Enclosure shall have IP54 degree of protection for HT & LT switchgear compartment & IP 23 degree of protection for transformer compartment. The enclosure exterior shall be painted with epoxy based powder paint (colour RAL 7032). Each compartment will be provided with the door and pad locking arrangement. The design of the enclosure should be type tested for suitablly handling any arcing inside the compartment for providing better safety to the operator. The compartment illumination lamp with door operated switch shall be provided for each compartment.Vacuum Interrupter,RMU,LT Switchgear, Multifunction meterand CSS Enciosure shall be of same make to ensure life cycle optimization. 82 Supply, installations, testing and commissioning factory made out door cubical typeLT panel board dust and verminproof , free standing, floor mounting type mounted on and incluidng1:3:6 PCC foundation as requried at site and of fabricated by 3.0mm thick CRCA Sheet over MS 50 X 50 x 6 mm thick angle iron frameof requriedtype for support with double door both sides open type with necessarylockingarrangement with sloppedroof on top duly paintedwith two coatsof powder coated semense gray paint complete and having separatedoors inside for accomodatingall incomming / outgoing feeders of suitable sizes all as specified and directedby Engr-in- Charge(Panel 1 - Near mains transformer GTC Area):- 83 INCOMING :-(i) S&F ACB 4 Pole 630 amps ,415 Volt electrical drawout type of breaking capacity not less than50 KA (Ics=100 % of Icu) with Adjustable TM Range (Optium 2.0) - 01 Nos Incommer.(ii) Aluminium electrolite Busbar 750 Amps current rating duly sleev insulated for set of 3 phase, 4 wire system and branch connection of suitable size of outgoing current rating of MCB/MCCBsOUTGOING:-(i) S&F MCCB 4 Pole 315 amps ,415 Volt of breaking capacity not less than16 KA (Ics=100 % of Icu) with Adjustable TM Range (Optium 2.0) - 01 No (for LT distribution panels of block )(ii) S&F MCCB 4 Pole 200 amps ,415 Volt of breaking capacity not less than16 KA (Ics=100 % of Icu) with adjustable thermal Setting (Optium 2.0) -02 Nos(for LTP Pump Motor, lift, fire fighting, stree light etc + spare).(iii)Digital Ammeter 0-500 A with selector switch & CTs of suitable capacity - 01 set.(ivDigital volt meter 0-400 V with selector switch - 01 No.(v)LED Indicating Lamps R,Y,B - 01 Set of three 84 Supply, installations, testing and commissioning factory made out door cubical typeLT panel board dust and verminproof , free standing, floor mounting type mounted on and incluidng1:3:6 PCC foundation as requried at site and of fabricated by 3.0mm thick CRCA Sheet over MS 50 X 50 x 6 mm thick angle iron frameof requriedtype for support with double door both sides open type with necessarylockingarrangement with sloppedroof on top duly paintedwith two coatsof powder coated semense gray paint complete and having separatedoors inside for accomodatingall incomming / outgoing feeders of suitable sizes all as specified and directedby Engr-in- Charge:- (Panel 2 - Near Chambal Vihar Main Tfr Panel):-INCOMING :-(a) S&F MCCB 4 Pole 500 amps ,415 Volt of breaking capacity not less than36 KA (Ics=100 % of Icu) with Adjustable TM Range (Optium 2.0) - 01 Nos Incommer.(b) Aluminium electrolite Busbar 600 Amps current rating duly sleev insulated for set of 3 phase, 4 wire system and branch connection of suitable size of outgoing current rating of MCB/MCCBs 85 OUTGOING:-(i) S&F MCCB 4 Pole 250 amps ,415 Volt of breaking capacity not less than25 KA (Ics=100 % of Icu) with Adjustable TM Range (Optium 2.0) - 01 No (for LT distribution panels of blocks)(ii) S&F MCCB 4 Pole 160 amps ,415 Volt of breaking capacity not less than25 KA (Ics=100 % of Icu) with adjustable thermal Setting (Optium 2.0) -02 Nos(for LTP Pump Motor, lift, fire fighting, stree light etc + spare).(iii)Street light timer using Power contactor 32 Amps, (1-NO) 3 pole, 415Volt, DIN Type digital programable time switch 230V AC, Auto/Manual selector switch, MCB 4 pole 25 Amps C-range, ON/OFF indicator all prewired and making provision for fixing outgoing cables- 01 Set complete.(iv)Digital Ammeter 0-500 A with selector switch & CTs of suitable capacity - 01 set.(v)Digital volt meter 0-400 V with selector switch - 01 No.(vi)LED Indicating Lamps R,Y,B - 01 Set of three 86 Supply, installations, testing and commissioning factory made out door cubical typeLT panel board dust and verminproof , free standing, floor mounting type mounted on and incluidng1:3:6 PCC foundation as requried at site and of fabricated by 3.0mm thick CRCA Sheet over MS 50 X 50 x 6 mm thick angle iron frameof requriedtype for support with double door both sides open type with necessarylockingarrangement with sloppedroof on top duly paintedwith two coatsof powder coated semense gray paint complete and having separatedoors inside for accomodatingall incomming / outgoing feeders of suitable sizes all as specified and directedby Engr-in- Charge:- (Panel 1A - LT PANEL FOR 3 X BLOCKS GTC):-INCOMING :-(i) S&F MCCB 4 Pole 315 amps ,415 Volt of breaking capacity not less than36 KA (Ics=100 % of Icu) with Adjustable TM Range (Optium 2.0) - 01 Nos Incommer.(ii) Aluminium electrolite Busbar 400 Amps current rating duly sleev insulated for set of 3 phase, 4 wire system and branch connection of suitable size of outgoing current rating of MCB/MCCBs 87 OUTGOING:-(i) S&F MCCB 4 Pole 125 amps ,415 Volt of breaking capacity not less than25 KA (Ics=100 % of Icu) with Adjustable TM Range (Optium 2.0) - 04 No (for 3 X Blocks+spare)(ii) Digital Ammeter 0-500 A with selector switch & CTs of suitable capacity - 01 set.(iii)Digital volt meter 0-400 V with selector switch - 01 No.(iv)LED Indicating Lamps R,Y,B - 01 Set of three 88 Supply, installations, testing and commissioning factory made out door cubical typeLT panel board dust and verminproof , free standing, floor mounting type mounted on and incluidng1:3:6 PCC foundation as requried at site and of fabricated by 3.0mm thick CRCA Sheet over MS 50 X 50 x 6 mm thick angle iron frameof requriedtype for support with double door both sides open type with necessarylockingarrangement with sloppedroof on top duly paintedwith two coatsof powder coated semense gray paint complete and having separatedoors inside for accomodatingall incomming / outgoing feeders of suitable sizes all as specified and directedby Engr-in- Charge:- (Panel 2A - LT PANEL FOR 2 X BLOCKS CHAMBAL VIHAR):-INCOMING :-(i) S&F MCCB 4 Pole 250 amps ,415 Volt of breaking capacity not less than36 KA (Ics=100 % of Icu) with Adjustable TM Range (Optium 2.0) - 01 Nos Incommer.(ii) Aluminium electrolite Busbar 400 Amps current rating duly sleev insulated for set of 3 phase, 4 wire system and branch connection of suitable size of outgoing current rating of MCB/MCCBs 89 OUTGOING:-(i) S&F MCCB 4 Pole 125 amps ,415 Volt of breaking capacity not less than25 KA (Ics=100 % of Icu) with Adjustable TM Range (Optium 2.0) - 03 No (for 3 X Blocks+spare)(ii) Digital Ammeter 0-500 A with selector switch & CTs of suitable capacity - 01 set.(iii)Digital volt meter 0-400 V with selector switch - 01 No.(iv)LED Indicating Lamps R,Y,B - 01 Set of three 90 Supply, installations, testing and commissioning factory made out door cubical typeLT panel board dust and verminproof , free standing, floor mounting type mounted on and incluidng1:3:6 PCC foundation as requried at site and of fabricated by 3.0mm thick CRCA Sheet over MS 50 X 50 x 6 mm thick angle iron frameof requriedtype for support with double door both sides open type with necessarylockingarrangement with sloppedroof on top duly paintedwith two coatsof powder coated semense gray paint complete and having separatedoors inside for accomodatingall incomming / outgoing feeders of suitable sizes all as specified and directedby Engr-in- Charge:- (Panel 1B & 2B):-INCOMING :-(i) S&F MCCB 4 Pole 200 amps ,415 Volt of breaking capacity not less than25 KA (Ics=100 % of Icu) with Adjustable TM Range-01 No incoming.(ii) Aluminium Electrolite Busbar 300Amps current rating duly sleev insulated for set of 3 phase, 4 wire system and branch connection of suitable size of outgoing current rating of MCB/MCCBs-01Set 91 OUTGOING:-(i) MCCB 4 pole 63 Amp, 415 V, 16 KA, C-series. - 01 Nos (for PH Panel)(ii) MCCB 4 pole 40 Amp, 415 V, 16 KA, C-series- 02 Nos (sewage PH +spare).(iii) MCB TPN 25Amp, 230 V, 10 KA, C-series - 07 Nos (Lifts+fire fighting+Street lights)(iv)Street light timer using Power contactor 25 Amps, (1-NO) 3 pole, 415Volt, DIN Type digital programable time switch 230V AC, Auto/Manual selector switch, MCB 4 pole 25 Amps C-range, ON/OFF indicator all prewired and making provision for fixing outgoing cables- 01 Set complete.(v) Digital Ammeter 0-150 A with selector switch & CTs of suitable capacity - 01 set.(vi) Digital volt meter 0-500 V with selector switch - 01 No. (vii) On load Change over switch 4 pole of current raring 63-100 A (open execution type) - 01 No.(viii)LED Indicating Lamps R,Y,B - 01 Set of three 92 Supply, installations, testing and commissioning factory made out door cubical typeLT panel board dust and verminproof , free standing, floor mounting type mounted on and incluidng1:3:6 PCC foundation as requried at site and of fabricated by 3.0mm thick CRCA Sheet over MS 50 X 50 x 6 mm thick angle iron frameof requriedtype for support with double door both sides open type with necessarylockingarrangement with sloppedroof on top duly paintedwith two coatsof powder coated semense gray paint complete and having separatedoors inside for accomodatingall incomming / outgoing feeders of suitable sizes all as specified and directedby Engr-in- Charge:- (Panel D - DOE Area):-INCOMING :-(i) S&F MCCB 4 Pole 100 amps ,415 Volt of breaking capacity not less than16 KA (Ics=100 % of Icu) with adjustable thermal Setting (Optium 2.0)-01 No incoming.(ii) Aluminium Electrolite Busbar 150 Amps current rating duly sleev insulated for set of 3 phase, 4 wire system and branch connection of suitable size of outgoing current rating of MCB/MCCBs-01Set 93 OUTGOING:-(i) MCCB 4 pole 63 Amp, 415 V, 16 KA, C-series - 02 Nos (for Bldg + Spare)(ii) MCB SPN 10 Amp, 415 V, 10 KA, C-series - 02 Nos (Garages + Spare).(iii) MCB SPN 10 Amp, 230 V, 10 KA, C-series - 02 Nos (Security light + Spare)(iv) Digital Ammeter 0-150 A with selector switch & CTs of suitable capacity - 01 set.(v) Digital volt meter 0-500 V with selector switch - 01 No.(vi)LED Indicating Lamps R,Y,B - 01 Set of three 94 M&L for factory made busbar box 750 Amps rated Aluminium busbar, 3 phase, 4 wire, 415 Volt of size not less than 300mm x 200mm x 100mm, fabricated using 1.6mm MS sheet, duly painted with smoke gray powder coated over a coat of red oxide primer suitable for fixing on wal by using wall fastners 10mm dia and making necessary incomming and outgoing connection of electric cables using aluminium lugs etc complete all as specified and diected. 95 M&L for factory made busbar box 600 Amps rated Aluminium busbar, 1 phase, 245 Volt, size not less than 200mm x 150mm x 100mm, fabricated using 1.6mm MS sheet, duly painted with smoke gray powder coated over a coat of red oxide primer suitable for fixing on wall by using wall fastners 10mm dia and making necessary incomming and outgoing connection of electric cables using aluminium lugs etc complete all as specified and diected. 96 Supply and fixing poly carbonatejunction box , weather and vermin proof of size 250X250X160 including provn of 4 Nos aluminium strip 25x3.15 mm size bus bar single phase and neutral suitabely mounted on bus bar insulators ,including one No. MCB SP 6 Amps for light control,drilling of holes.Provn of suitable size of GI nuts, bolts, double washer and FI clamps ofsuitable sizefor taking connections and fixing on LT steel tubular poles complete with locking arrangementcomplete all as specified and directed. 97 Supply and connecting three core cord flexible wire, copper conductor multistranded, PVC insulated and overall PVC sheathed of size 1.5Sqmm 1100 Volt , draw through LT steel tubular polesfor connection to street light from junction boxetc complete all as specified & directed. 98 S&F for Cable route indicator, duly engraved with LT CABLE 1100 VOLT on cast iron round plate 150 mm dia with provision of 500 mm long (minimum) single leg/stand of flat iron 40 x 5 mm, welded/riveted on back side of plate, fixed and grouted in position with PCC 1:3:6 type C-1, block of suitable size etc complete all as specified & directed. 99 M&L for Precast PCC (1:2:4) type B-1 cable path indicators of size 300x100x500mm rounded top having engraved in capital letters HT Cable embedded in position in PCC(1:3:6) Type C-1, using necessary formwork and including provision of two coats of cement base paint on exposed concrete surface and writing HT Cable in black synthetic enamel paint etc complete all as specified & directed. 100 M&L fordecorative LED post top lantern (PTL) luminior with die cast aluminium spigot, spun aluminium powder coated top cover clear/opal acralic difusser LED light fitting of 25 watts including LED lamp etc complete all as specified & directed. 101 M& L for shifting of 33 KV HT cable to a safe distance from proposed building, supply, laying, testing & commisioning of 33 KV cable in replacement with new as per estimate provided by State electricity deptetc etc complete all as specified & directed. 102 FIRE FIGHTINGS&F forAutomatic air release valve 50mm dia suitable for domestic water with 25mm gun metal stop valveetc complete all as specified & directed. 103 S&F forbranch pipe with nozzle of 20mm dia for hose reel conforming to IS 8090etc complete all as specified and directed. 104 S&F forfix Valve, stop, screwed, 25 mmdia pipeetc complete all as specified and directed. 105 S&F for6 kg capacity Multipurpose dry chemical powder (ABC) type(IS-15683) fire extinguishers consisting of welded MS cylindrical body fabricated from 1.6 mm MS sheet internally protected with anticorrosive treatment and hydraucally tested. Extinguisher externally painted with red enamel and fixed to wall with bracket complete with initial filled/charged .etc complete all as specified and directed. 106 S&F forCO2 type fire extinguisher of 3 Kgs capacity with steel cylinder with a discharge valve and confirming to IS : 15683.Extinguisher shall be painted with red enamel apint and fixed to wall with bracket etc complete all as specified and directed. 107 S&F for9 Ltr capacity Foam type(IS-15683) fire extinguishers consisting of welded MS cylindrical body fabricated from 1.6 mm MS sheet internally protected with anticorrosive treatment and hydraucally tested. Extinguisher externally painted with red enamel and fixed to wall with bracket complete with initial filled/chargedetc complete all as specified and directed. 108 S&F fortesting of Star-Delta starter Panel for fire fighting pump motor etc complete all as specified and directed. 109 Supply, installation, testing & commissioning ofFIRE SIGNAGES for indication/information of fire exit, alarm panel, fire extinguishers fire axe, hose reel, hydrents, lifts of size 300mmx100mm etc complete all as specified and directed. 110 DG SETSSupply, installation, commissioning and testing complete of Manufacturer of OEM (Original Eqpt Manufacturer) manufactured and tested static Diesel Engine driven generating set capable of delivering 180 KVA continuous rating, (10% overload for 1 hour in 12 hours of operation), 415 volts (AC 3 phase, 4 wire system of supply), 50 Hz at power factor 0.8 minimum. The DG set shall consist of a diesel engine coupled directly to a matching alternator, and mounted on Dunlop metallastik foundation pads on a common base frame and thereafter installed in the CPCB approved acoustic enclosure complete with control panel standardised by manufacturer, fuel tank with mounting arrangement and inlet, outlet, return oil arrangement, flexible exhaust pipe complete all as specified and directed and shall include comprise of the following :- 111 (A) Engine (prime mover) : Diesel engine 1500 RPM, of suitable HP as recommended by manufacturer, water cooled, turbocharged, 12 volts electric battery start, complete with fly wheel and torsional vibration damper, rediator and all standard fittings/fixtures as per standard manufacturing practices and including suitable instrument panel with RPM meter, lub oil temp and pressure gauge, water temp gauge and frequency meter (digital type), battery charging ammeter and fuses, and also including self starter (12V), battery charging alternator, fuel tank etc and complete with HWT and LLOP alarm and shut down safeties complete with first fill of Lub oil and Coolent. (B) Alternator : AC alternator, brushless, 415V AC 50 Hz, 3 phase, 4 wire type, rated for continuous output of 63 KVA, PF 0.8 (lag), 1500 RPM insulation class H; enclosure SPDP (IP 22/23), self excited & self regulated with AVR for + 1% voltage regulation, coupled directly/suitably to and to match the above engine and conforming to BS 5000/IS 4722. 112 (C) Dunlop Metallastik anti-vibration of pads for mounting engine - alternator assembly on the base frame/plate.(D) Base plate : Made out of structural steel as per manufacturers recommended design/specifications.(E) Enclosure : Provision of an integral type, approved/certified acoustic enclosure as per latest CPCB norms, for the DG set to restrict the noise level to 75 DB (A) at one metre and ensure that temperature rise within the canopy shall not exceed 5 - 7 degree celsius, It shall be made of 16 SWG CRCA MS sheet with powder-coated finish on outside and high quality noise absorbent and fire retardant grade acuoustic insulation material duly provided with EPDN gasket lining. There shall be four hinged doors out of which one shall be with a glass window.(i)Silencer : Absorption type, non-resistance, residential.(ii) Internal wiring with PVC copper conductor cables, IS 694 marked, FRLS in conduit and suitable light fittings.(iii)Fuel tank to be provided as per OEM specificaton.(iv)Safeties for high enclosure temperature and emergency shut-down from outside.(v) 1No 12V of suitable AH lead acid batteries and adequate size copper conductor cable leads, housed on & including suitable size MS angle iron frame and necessary clamps, nuts, bolts, washers all as required & as per manufacturer design/specifications.(F) Control panel : Control panel made out of 14 gauge CRCA sheet, powder coated and shall consists of the following: - 113 (i) Ps 0500 Controller (ii) Aluminium Bus bars with suitable capacity incoming & outgoing terminals.(iii) Indicating lamps for load on and set running (iv) Instrument fuses duly wired and ferruled. (v) Circuit breaker(MCCB) of suitable rating with overload and short circuit protections. Note: To be mounted inside enclosure. (G) Automatic mains failure (AMF) control panel fabricated from CRCA sheet steel of thickness not less than 3.15 mm, suitable for outdoor installation (including CPRI type test certified), dust & vermin proof, protection class I P-54 suitable for 415 volts, 3 phase, 4 wire, 50 Hz, AC supply system with adequate layers of power coating floor mounting type with front opening, the AMF panel shall comprise the following indicating instruments & switches:- 114 AC voltmeter - 01NoVoltmeter selector switch OFF/RY/YB/BR - 01NoFrequency meter - 01NoAC voltmeter of suitable scale - 01NoAmmeter selector switch OFF/R/Y/B - 01NoCurrent transformers of suitable ratio - 01NoBattery charger consisting of - 01No(aa) Transformer / Rectifier unit (bb) DC ammeter /DC voltmeter(cc) Charging rate selector switch OFF/Trickle/BoostMains supply air break contactor, 3 pole of suitable raing - 01NoAlternator air break contactor, 3 pole of suitable rating and provided with a separate overload relay for overload protection - 01NoMains supply voltage monitor - 01NoSet of DC control relays and timers - 01NoSet of push buttons, START, STOP, ACKNOWLEDGE, RESET, MAINS BREAKER, CLOSE/TRIP, ALTERNATOR BREAKER CLOSE / TRIP - 01No 115 01 Set of indicating lamps for the following :-LOAD ON MAINS, LOAD ON SET, SET FAILS TO START, LOW OIL PRESSURE, HIGH TEMPERATURE ALARM, HIGH TEMPERATURE TRIP, ALTERNATOR OVERLOAD.Audio - alarm hooter - 01NoKWH meter - One Set of Bus bars - 01NoThe control cubicle will be furnished complete with the necessary control circuit fuses, etc. and will have provisions for making incoming and outgoing connections.KW meter - 01Noset of bus bar - 01NoThe control cubical will be furnished complete with the necessary control circuit fuse etc and will have provision for making incoming and outgoing connectionsOne - set of bus bar - 01NoThe control cubicle will be furnished complete with the necessary control circuit fuses, etc. and will have provisions for making incoming and outgoing connections.Note :(i) In case AMF panel included instead of Standard Control Panel, then Battery charging alternator with inbuilt regulator and battery charging ammeter should be deleted from engine specifications since Battery charger included under AMF Panel specifications. 116 (ii) Platform : PCC foundation /plinth/baseshall be provided as per drawing No: TD/2010/109, Sheet No 1/1.(iii) Tool kit, Operation and Maintenance catalogue, 1 year spare part list, overhauling manuals, guarantee card etc shall be provided as per manufacturer standard practices. 117 Supply, installation, commissioning and testing complete of Manufacturer of OEM (Original Eqpt Manufacturer) manufactured and tested static Diesel Engine driven generating set capable of delivering 125 KVA continuous rating, (10% overload for 1 hour in 12 hours of operation), 415 volts (AC 3 phase, 4 wire system of supply), 50 Hz at power factor 0.8 minimum. The DG set shall consist of a diesel engine coupled directly to a matching alternator, and mounted on Dunlop metallastik foundation pads on a common base frame and thereafter installed in the CPCB approved acoustic enclosure complete with control panel standardised by manufacturer, fuel tank with mounting arrangement and inlet, outlet, return oil arrangement, flexible exhaust pipe complete all as specified and directed and shall include comprise of the following :- 118 (A) Diesel engine 1500 RPM, of suitable HP as recommended by manufacturer, water cooled, turbocharged, 12 volts electric battery start, complete with fly wheel and torsional vibration damper, rediator and all standard fittings/fixtures as per standard manufacturing practices and including suitable instrument panel with RPM meter, lub oil temp and pressure gauge, water temp gauge and frequency meter (digital type), battery charging ammeter and fuses, and also including self starter (12V), battery charging alternator, fuel tank etc and complete with HWT and LLOP alarm and shut down safeties complete with first fill of Lub oil and Coolent. (B) Alternator : AC alternator, brushless, 415V AC 50 Hz, 3 phase, 4 wire type, rated for continuous output of 63 KVA, PF 0.8 (lag), 1500 RPM insulation class H; enclosure SPDP (IP 22/23), self excited & self regulated with AVR for + 1% voltage regulation, coupled directly/suitably to and to match the above engine and conforming to BS 5000/IS 4722. (C)Dunlop Metallastik anti-vibration of pads for mounting engine - alternator assembly on the base frame/plate. 119 (D) Base plate : Made out of structural steel as per manufacturers recommended design/specifications.(E) Enclosure : Provision of an integral type, approved/certified acoustic enclosure as per latest CPCB norms, for the DG set to restrict the noise level to 75 DB (A) at one metre and ensure that temperature rise within the canopy shall not exceed 5 - 7 degree celsius, It shall be made of 16 SWG CRCA MS sheet with powder-coated finish on outside and high quality noise absorbent and fire retardant grade acuoustic insulation material duly provided with EPDN gasket lining. There shall be four hinged doors out of which one shall be with a glass window.(i)Silencer : Absorption type, non-resistance, residential.(ii) Internal wiring with PVC copper conductor cables, IS 694 marked, FRLS in conduit and suitable light fittings.(iii)Fuel tank to be provided as per OEM specificaton.(iv)Safeties for high enclosure temperature and emergency shut-down from outside.(v) 1Nos 12V of suitable AH lead acid batteries and adequate size copper conductor cable leads, housed on & including suitable size MS angle iron frame and necessary clamps, nuts, bolts, washers all as required & as per manufacturer design/specifications. 120 (F) Control panel : Control panel made out of 14 gauge CRCA sheet, powder coated and shall consists of the following: - (i) Ps 0500 Controller (ii) Aluminium Bus bars with suitable capacity incoming & outgoing terminals.(iii) Indicating lamps for load on and set running(iv) Instrument fuses duly wired and ferruled. (v) Circuit breaker(MCCB) of suitable rating with overload and short circuit protections. Note: To be mounted inside enclosure. (G) Automatic mains failure (AMF) control panel fabricated from CRCA sheet steel of thickness not less than 3.15 mm, suitable for outdoor installation (including CPRI type test certified), dust & vermin proof, protection class I P-54 suitable for 415 volts, 3 phase, 4 wire, 50 Hz, AC supply system with adequate layers of power coating floor mounting type with front opening, the AMF panel shall comprise the following indicating instruments & switches:- AC voltmeter -01 NoVoltmeter selector switch OFF/RY/YB/BR - 01 No 121 Frequency meter - 01 NoAC voltmeter of suitable scale - 01 NoAmmeter selector switch OFF/R/Y/B - 01 NoCurrent transformers of suitable ratio - 01 NoBattery charger consisting of - 01 No(aa) Transformer / Rectifier unit (bb) DC ammeter /DC voltmeter(cc) Charging rate selector switch OFF/Trickle/BoostMains supply air break contactor, 3 pole of suitable raing - 01 NoAlternator air break contactor, 3 pole of suitable rating and provided with a separate overload relay for overload protection - 01 NoMains supply voltage monitor - 01 NoSet of DC control relays and timers - 01 NoSet of push buttons, START, STOP, ACKNOWLEDGE, RESET, MAINS BREAKER, CLOSE/TRIP, ALTERNATOR BREAKER CLOSE / TRIP - 01 No01 Set of indicating lamps for the following :-LOAD ON MAINS, LOAD ON SET, SET FAILS TO START, LOW OIL PRESSURE, HIGH TEMPERATURE ALARM, HIGH TEMPERATURE TRIP, ALTERNATOR OVERLOAD.Audio - alarm hooter - 01NoKWH meter - One Set of Bus bars - 01NoThe control cubicle will be furnished complete with the necessary control circuit fuses, etc. and will have provisions for making incoming and outgoing connections. 122 KW meter - 01Noset of bus bar - 01NoThe control cubical will be furnished complete with the necessary control circuit fuse etc and will have provision for making incoming and outgoing connectionsOne - set of bus bar - 01NoThe control cubicle will be furnished complete with the necessary control circuit fuses, etc. and will have provisions for making incoming and outgoing connections.Note :(i) In case AMF panel included instead of Standard Control Panel, then Battery charging alternator with inbuilt regulator and battery charging ammeter should be deleted from engine specifications since Battery charger included under AMF Panel specifications. 123 (ii) Platform : PCC foundation /plinth/baseshall be provided as per drawing No: TD/2010/109, Sheet No 1/1.(iii) Tool kit, Operation and Maintenance catalogue, 1 year spare part list, overhauling manuals, guarantee card etc shall be provided as per manufacturer standard practices. 124 Supply, installations, testing of electric chimney of size 60cm havingsuction capacity of 1200 cum per hour with filterless technology sealed motor and insulationfor oil deposit and water vapour alongwith self autoclean feature after 30 cycles of operation and minimum 5 year warranty etc etc complete all as specified and directed.
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 5
27.
Public Administrative Department #11276744 Technical Bid
Tender for Labour Engaged For Desilting,Readjustment Of Manholes Covers, Diverting The Direction Of Water Dewatering During The Execution Of Work And Disposal Away From Site. , Dismantling Tile Work In Floors And Roofs Laid In Cement Mortar Including Stacking Material Within 50 Meters Lead For Thickness Of Tiles Above 25 Mm And Upto 40 Mm. , Dismantling Dressed Stone Work Ashlar Face Stone Work, Marble Work Or Precast Concrete Work Manually/By Mechanical Means Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Meters Lead As Per Direction Of Engineer-In-Charge , Dismantling Roofing Including Ridges, Hips Valleys And Gutters Etc., And Stacking The Material Within 50 Meters Lead. , Dismantling Of Flexible Pavement (Bituminous Courses) By Mechanical Means And Disposal Of Dismantled Material Upto A Lead Of 1 Kilometer, As Per Direction Of Engineer-In-Charge. , Dismantling Manually/ Mechanically Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Meters Lead As Per Direction Of Engineer-In-Charge: Bituminous Road. , Demolishing Cement Concrete Manually/By Mechanical Means Including Disposal Of Material Within 50 Meters Lead As Per Direction Of Engineer-Incharge:1:4:8 Or Leaner Mix (I/C Equivalent Design Mix) , Demolishing Lime Concrete Manually/By Mechanical Means And Disposal Of Material Within 50 Meters Lead As Per Direction Of Engineer-In-Charge. , Demolishing Brick Work Manually/By Mechanical Means Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Meters Lead As Per Direction Of Engineer-In-Charge:In Cement Mortar , Demolishing Cement Concrete Manually/By Mechanical Means Including Disposal Of Material Within 50 Meters Lead As Per Direction Of Engineer-Incharge: 15.2.1 1:3:6 Or Richer Mix (I/C Equivalent Design Mix) , Demolishing Reinforced Cement Concrete Work Manually/By Mechanical Means Including Stacking Of Steel Bars And Disposal Of Unserviceable Material Within 50 Meters Lead As Per Direction Of Engineer-In-Charge. , Demolishing R.B Work Manually/By Mechanical Means Including Stacking Of Steel Bars And Disposal Of Unserviceable Material Within 50 Meters Lead As Per Direction Of Engineer-In-Charge. , Earth Work In Excavation By Manual Means In Trenches For Foundations, Drains, Pipes, Cables Etc. (Not Exceeding 1.5 M In Width) And For Shafts, Wells, Cesspits And The Like Not Exceeding 10 Sqm On Plan, Including Dressing Of Sides And Ramming Of Bottoms Lift Upto 1.5 M, Including Getting Out Excavated Earth And Disposal Of Surplus Excavated Earth As Directed: All Kinds Of Soil : , Earth Work In Bulk Excavation By Mechanical Means (Hydraulic Excavator) Over Areas (Exceeding 30 Cm In Depth, 1.5 M In Width As Well As 10 M2 On Plan) Including Disposal Of Excavated Earth Lead Upto 50 Meters And Lift Upto 1.5 M, As Directed By Engineer-In-Charge. All Kinds Of Soil : , Earth Work In Surface Excavation Not Exceeding 30 Cm In Depth But Exceeding 1.5 M In Width As Well As10 Sqm On Plan Including Disposal Of Excavated Earth, Leadupto50meterand Lift Upto 1.5M, As Directed By Engineer-In-Charge.All Kinds Of Soil : , Earth Work In Excavation By Mechanical Means (Hydraulic Excavator) In Trenches For Foundations, Drains, Pipes, Cables Etc. (Not Exceeding 1.5 M In Width) And For Shafts, Wells, Cesspits And The Like Not Exceeding 10 Sqm On Plan, Including Dressing Of Sides And Ramming Of Bottoms Lift Upto 1.5 M, Including Getting Out Excavated Earth And Disposal Of Surplus Excavated Earth As Directed, Within A Lead Of 50 Metres:All Kinds Of Soil : , Removal Of Excavated Mulba Dismantled Or Unserviceable Material From The Site Of Work By Mechanical Transport Or Animal Transport Or Otherwise Including Loading/Unloading(Complete Job) , Providing And Laying In Position Cement Concrete Of Specified Grade Including Curing But Excluding The Cost Of Centring And Shuttering. All Work Upto Plinth Level With:1:4:8 (1 Cement : 4 Coarse Sand : 8 Graded Stone Aggregate 40 Mm Nominal Size) , Providing And Laying In Position Cement Concrete Of Specified Grade Including Curing But Excluding The Cost Of Centring And Shuttering. All Work Upto Plinth Level With: 4.4.8 1:5:10 (1 Cement : 5 Coarse Sand : 10 Graded Stone Aggregate 40 Mm Nominal Size) , Providing And Laying In Position Cement Concrete Of Specified Grade Including Curing But Excluding The Cost Of Centring And Shuttering. All Work Upto Plinth Level With:1:2:4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size) , Providing And Laying In Position Cement Concrete Of Specified Grade Including Curing But Excluding The Cost Of Centring And Shuttering. All Work Upto Plinth Level With:1:3:6 (1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20 Mm Nominal Size) , Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete Including Curing But Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement. All Works Upto Plinth Level 1:1½:3 (1 Cement : 1½ Coarse Sand : 3 Graded Stone Aggregate 20 Mm Nominal Size) , Providing And Laying Cement Concrete In Retaining Walls, Return Walls, Walls (Any Thickness) Including Attached Pilasters, Columns, Piers, Abutments, Pillars, Posts,Struts, Buttresses, String Or Lacing Courses, Parapets, Coping, Bed Blocks, Anchors Blocks, Plain Window Sills, Fillets Etcupto Floor V Level, Including Curing But Excluding The Cost Of Centring, Shuttering And Finishing With.1:3:6 (1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20 Mm Nominal Size) , Reinforced Cement Concrete Work In Walls (Any Thickness) Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Upto Floor Five Level Including Curing But Excluding Cost Of Centering Shuttering, Finishing And Reinforcement. 1½:3 (1 Cement : 1½ Coarse Sand : 3 Graded Stone Aggregate 20 Mm Nominal Size) , Providing And Laying In Position Ready Mixed M-25 Grade Concrete For Reinforced Cement Concrete Work, Using Cement Content As Per Approved Design Mix, Manufactured In Fully Automatic Batching Plant And Transported To Site Of Work In Transit Mixer For All Leads, Having Continuous Agitated Mixer, Manufactured As Per Mix Design Of Specified Grade For Reinforced Cement Concrete Work Including Pumping Of R.M.C. From Transit Mixer To Site Of Laying , Excluding The Cost Of Centering, Shuttering Finishing And Reinforcement Including Cost Of Admixtures In Recommended Proportions As Per Is : 9103 To Accelerate/ Retard Setting Of Concrete, Improve Workability Without Impairing Strength And Durability As Per Direction Of The Engineer- In - Charge. Note: - Cement Content Considered In This Item Is @ 330 Kg/ Cum. Excess/ Less Cement Used As Per Design Mix Is Payable/ Recoverable Separately.All Works Upto Plinth Level , Providing And Laying In Position Ready Mixed M-25 Grade Concrete For Reinforced Cement Concrete Work, Using Cement Content As Per Approved Design Mix, Manufactured In Fully Automatic Batching Plant And Transported To Site Of Work In Transit Mixer For All Leads, Having Continuous Agitated Mixer, Manufactured As Per Mix Design Of Specified Grade For Reinforced Cement Concrete Work Including Pumping Of R.M.C. From Transit Mixer To Site Of Laying , Excluding The Cost Of Centering, Shuttering Finishing And Reinforcement Including Cost Of Admixtures In Recommended Proportions As Per Is : 9103 To Accelerate/ Retard Setting Of Concrete, Improve Workability Without Impairing Strength And Durability As Per Direction Of The Engineer- In - Charge. Note: - Cement Content Considered In This Item Is @ 330 Kg/ Cum. Excess/ Less Cement Used As Per Design Mix Is Payable/ Recoverable Separately. All Works Above Plinth Level Upto Floor V Level , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form Work For: Foundations, Footings, Bases For Columns , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form Work For Retaining Walls, Return Walls, Walls (Any Thickness) Including Attached Pilasters Buttresses, Plinth And String Course Fillets, Kerbs Andsteps Etc. , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For: Lintel, Beams, Plinth Beams, Girders, Bressumers And Cantilevers , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For:Columns, Pillars, Piers, Abutments, Posts And Struts. , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For:Edges Of Slabs And Breaks In Floors And Walls , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For: Suspended Floors, Roofs, Landings, Balconies And Access Platforms. , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For: Arches, Domes, Vaults Upto 6 M Span , Steel Reinforcement For Reinforced Cement Concrete Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Above Plinth Level With Cold Twisted Bar , Steel Work Welded In Built Up Sections/Framed Work, Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer Using Structural Steel Etc. As Required.In Gratings, Frames, Guard Bar, Ladder, Railings, Brackets, Gates And Similar Works. , Structural Steel Work In Built Up Sections, Trusses And Framed Work, Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer All Complete. Welded , Providing And Laying River Bed Material On The Road Surface By Way Of Spreading The Same In Uniform Layer Not Exceeding 20Cm In Depth, Watering And Compacting With Vibratory Power Road Roller Of 8-10 Tonne Capacity Incl Carriage Of Material From Source To Site Of Work (All Leads , Lifts Complete).The Measurement Is To Be Taken Of Compacted / Finished Work. , Filling Available Excavated Earth (Excluding Rock) In Trenches, Plinth, Sides Of Foundations Etc. In Layers Not Exceeding 20 Cm In Depth, Consolidating Each Deposited Layer By Ramming And Watering, Lead Upto 50 M And Lift Upto 1.5 M. , Surface Dressing Of The Ground Including Removing Vegetation And In-Equalities Not Exceeding 15 Cm Deep And Disposal Of Rubbish, Lead Upto 50 M And Lift Upto 1.5 M In -All Kinds Of Soil. , Providing And Fixing 60Mm Interlocked Paver Tile Over A Layer Of Cement Mortar 1:4 Mix Incl Filling Of Joints With Cement Mortar 1:3 (Complete Job) , Providing And Laying Factory Made Chamfered Edge Cement Concrete Paver Blocks In Footpath, Parks, Lawns, Drive Ways Or Light Traffic Parking Etc, Of Required Strength, Thickness & Size/ Shape, Made By Table Vibratory Method Using Pu Mould, Laid In Required Colour & Pattern Over 50Mm Thick Compacted Bed Of Sand, Compacting And Proper Embedding/Laying Of Inter Locking Paver Blocks Into The Sand Bedding Layer Through Vibratory Compaction By Using Plate Vibrator, Filling The Joints With Sand And Cutting Of Paver Blocks As Per Required Size And Pattern, Finishing And Sweeping Extra Sand Complete All As Per Direction Of Engineer-In-Charge. 80 Mm Thick cement concrete Paver Block Of M-30 Grade With Approved Color Design And Pattern. , 12Mm Cement Plaster Of Mix: 1 : 6 ( 1 Cement : 6 Fine Sand) , 12Mm Cement Plaster Of Mix: 1 : 4 ( 1 Cement : 4 Fine Sand) , Brick Work With Common Burnt Clay (Non-Modular) Bricks Of Class Designation 7.5 In Foundation And Plinth Including Curing In : Cement Mortar 1:6 ( 1 Cement : 6 Coarse Sand) , Extra For Brick Work With Common Burnt Clay Bricks/Cement Concrete Bricks In Superstructure Above Plinth Level Upto Floor Five Level , Tile Brick Masonry With Common Burnt Clay Tile Bricks Of Class Designation 10 In Foundation And Plinth Including Curing Complete In: Lime Mortar 1:1:1 (1 Lime Putty : 1 Surkhi : 1 Fine Sand) , Providing And Laying Bituminous Macadam Using Crushed Stone Aggregates Of Specified Grading Premixed With Bituminous Binder, Transported To Site By Tippers, Laid Over A Previously Prepared Surface With Paver Finisher Equipped With Electronic Sensor To The Required Grade, Level And Alignment And Rolling With Smooth Wheeled, Vibratory And Tandem Rollers As Per Specifications To Achieve The Desired Compaction And Density, Complete As Per Specifications And Directions Of Engineer-In-Charge. 50 To 100 Mm Average Compacted Thickness With Bitumen Ofgrade Vg-30 @ 3.5% (Percentage By Weight Of Total Mix) Prepared In Drum Type Hot Mix Plant Of 60-90 Tph Capacity , Supplying,Stacking, Laying, Spreading And Compacting Graded Stone Aggregate To Wet Bound Macadam (Wbm-Iii) With Graded Crushed Stone Aggregate Of Size 53Mm To 22.4 Mm In Uniform Thickness,Hand Picking , Rolling With Vibratory Roller 8-10 Tonne Capacity In Stages To Proper Grade And Camber,Applying And Brooming Requisite Type Screening / Binding Material To Fill Up Interstices Of Coarse Aggregate,Watering And Compacting To The Required Density.Complete Job , Providing And Applying Tack Coat Using Hot Straight Run Bitumen Of Grade - Vg-30, Including Heating The Bitumen, Spraying The Bitumen With Mechanically Operated Spray Unit Fitted On Bitumen Boiler, Cleaning And Preparing The Existing Road Surface As Per Specifications. On Bitumen Surface @ 0.50 Kg/Sqm. , Hand-Packing Stones In Wire-Crates; Excluding Cost Of Crates And Stones , Providing And Applying Tack Coat Using Hot Straight Run Bitumen Of Grade - Vg-30, Including Heating The Bitumen, Spraying The Bitumen With Mechanically Operated Spray Unit Fitted On Bitumen Boiler, Cleaning And Preparing The Existing Road Surface As Per Specifications.16.38.1 On W.B.M. @ 0.75 Kg/Sqm. , Providing And Laying Seal Coat Of Premixed Fine Aggregate (Passing 2.36 Mm And Retained On 180 Micron Sieve) With Bitumen Using 128 Kg Of Bitumen Of Grade Vg-30 Bitumen Per Cum Of Fine Aggregate And 0.60 Cum Of Fine Aggregate Per 100 Sqm Of Road Surface Including Rolling And Finishing With Road All Complete , 2.5 Cm Premix Carpet Surfacing With 2.25Cum And 1.12 Cum Of Stone Chippings Of 13.2 Mm And 11.2Mm Size Respectively Per 100 Sqm And 52 Kg And 56 Kg Of Hot Bitumen Per Cum Of Stone Chippings Of 13.2 Mm And 11.2 Mm Size Respectively Including A Tack Coat With Hot Straight Run Bitumen Including Consolidation With Road Roller Of 6 To 9 Tonne Capacity Etc. Complete (Tack Coat To Be Paid For Separately). Vwith Paving Asphalt Grade Vg-30 With No Solvent , 10Cm Thick (Average) Mud Phaska Of Damped Brick Earth On Roofs Laid To Slope Consolidated And Plastered With 25 Mm Thick Mud Mortar Mixed With Bhusa At 35Kg Per Cum Of Earth And Gobri Leaping With Mix 1:1 (1 Clay: 1 Cow Dung) And Covered With Specified Tile Bricks Grouted With Cement Mortar 1:3 (1 Cement: 3 Fine Sand) Mixed With 2% Of Integral Water Proofing Compound By Weight Of Cement And Finishing Neat. 12.25.1 With Common Burnt Clay (Non Modular) Brick Tiles Of Class Designation 10.0 , Providing And Fixing Precoated Galvanized Iron Profile Sheets (Size, Shape And Pitch Of Corrugation As Approved By Engineer-In-Charge) 0.50 Mm (+ 0.05 %) Total Coated Thickness With Zinc Coating 120 Grams Per Sqm As Per Is: 277, In 240 Mpa Steel Grade, 5-7 Microns Epoxy Primer On Both Side Of The Sheet And Polyester Top Coat 15-18 Microns. Sheet Should Have Protective Guard Film Of 25 Microns Minimum To Avoid Scratches During Transportation And Should Be Supplied In Single Length Upto 12 Metre Or As Desired By Engineer-In-Charge. The Sheet Shall Be Fixed Using Self Drilling /Self Tapping Screws Of Size (5.5X 55 Mm) With Epdm Seal, Complete Upto Any Pitch In Horizontal/ Vertical Or Curved Surfaces, Excluding The Cost Of Purlins, Rafters And Trusses And Including Cutting To Size And Shape Wherever Required. , Providing And Fixing Precoated Galvanised Steel Sheet Roofing Accessories0.50 Mm (+0.05 %) Total Coated Thickness, Zinc Coating 120 Grams Per Sqm As Per Is: 277, In 240 Mpa Steel Grade, 5-7 Microns Epoxy Primer On Both Side Of The Sheet And Polyester Top Coat 15-18 Microns Using Self Drilling/ Self Tapping Screws Complete : 12.24.1 Ridges Plain (500 - 600Mm) 12.24.2 Flashings/ Aprons.(Upto 600 , Providing And Fixing 1Mm Thick M.S. Sheet Door With Frame Of 40X40x6mm Angle Iron And 3Mm M.S. Gusset Plates At The Junctions And Corners, All Necessary Fittings Complete, Including Applying A Priming Coat Of Approved Steel Primer. Using Flats 30X6mm For Diagonal Braces And Central Cross Piece. , Providing And Applying White Cement Based Putty Of Specified Thickness, Of Approved Brand And Manufacturer, Over The Plastered Wall Surface To Prepare The Surface Even And Smooth Complete. 2 Mm Thick , Wall Painting With Acrylic Emulsion Paint Of Approved Brand And Manufacture To Give An Even Shade. Two Or More Coats On New Work , Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture To Give An Even Shade. Two Or More Coats On New Work , Finishing Walls With Acrylic Smooth Exterior Paint Of Required Shade On New Work (Two Or More Coats Applied @ 1.67 Liter/10Sqm Over And Including Priming Coat Of Exterior Primer Applied @ 2.20Kg/10Sqm) , Providing And Laying Vitrified Floor Tiles In Different Sizes (Thickness To Be Specified By The Manufacturer) With Water Absorption Less Than 0.08% And Conforming To Is:15622 Of Approved Make, In All Colours And Shades, Laid On 20Mm Thick Cement Mortar 1:4 (1Cement :4 Coarse Sand) Including Grouting The Joints With White Cement And Matching Pigments Etc. Complete Size Of Tile 600X600 Mm , Chequerred Precast Cement Concrete Tiles 22Mm Thick In Footpath And Courtyard, Jointed With Neat Cement Slurry Mixed With Pigment To Match The Shade Of The Tiles, Including Rubbing, Cleaning And Curing Complete, On 20 Mm Thick Bed Of Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand) . Dark Shade Using Ordinary Cement. , Providing And Fixing 15 Mm Nominal Bore C.P. Brass Bib Cock Of Approved Quality Conforming To Is : 8931 , Providing And Fixing 15 Mm Nominal Bore C.P. Brass Long Nose Bib Cock Of Approved Quality Conforming To Is Standards And Weighing Not Less Than 810 Gms. , Pvc Bend , Providing And Fixing Of Pvc Pipe With All Fitting Complete Job , Providing And Fixing Of Pvc Pipe With All Fitting Complete Job , Providing And Fixing On Wall Face Un-Plasticized Rigid Pvc Rain Water Pipes Conforming To Is: 13592 Type A Including Jointing With Seal Ring Conforming To Is: 5382 Leaving 10 Mm Gap For Thermal Expansion. (I) Single Socketed Pipes 75 Mm Diametre , Providing And Fixing Of Pvc Including All Fitting With Complete Job , Providing And Fixing Of Towal Ring With All Fitting With Complete Job , Providing And Inserting Upvc Pipe ( Working Pressure4kg/ Cm2) Single Sockted Pipe 110 Mm Dia , Providing And Fixing G.I. Pipes Complete With G.I. Fittings And Clamps, Including Cutting And Making Good The Walls Etc.: Internal Work-Exposed On Wall 15 Mm Dia. Nominal Bore , Dumping Of Stone Including Cost Of Stone Filling, Including Supply Of Stone And Carriage Complete Job , Providing And Placing On Terrace (At All Floor Levels) Polyethylene Water Storage Tank Isi : 12701 Marked, With Cover And Suitable Locking Arrangement And Making Necessary Holes For Inlet, Outlet And Overflow Pipes But Without Fittings And The Base Support For Tank , Supply Of Wire Crates Of Approved Mesh Including Weaving Binding Sides And Partitionsand Binding Top After Filling Complete Job. , Extra For Every Additional Lift Of 1.5 M Or Part There Of Beyond 1.5 M Height For Hand-Packing Of Stones In Wire-Crates , Providing And Fixing Of Weep Hole With Pvc Pipe Of 100 Mm Dia Complete Job , Providing And Fixing Of Weep Hole With Pvc Pipe Of 110 Mm Dia Complete Job , Stone Work In Super Structure Upto Floor Five Level In Cement Mortar 1:6 ( 1 Cement :6 Coarse Sand) Including Pointing With Cement Mortar 1:2 ( 1 White Cement: 2 Stone Dust) With An Admixture Of Pigment Matching The Stone Shade And Curing Complete: White Sand Stone , Stone Work Plain Ashlar In Super Structure Upto Floor Five Level In Cement Mortar 1:3 ( 1 Cement :3 Coarse Sand) Including Centering, Shuttering And Pointing With Cement Mortar 1:2 ( 1 White Cement: 2 Stone Dust) With An Admixture Of Pigment Matching The Stone Shade And Curing Complete: Red Sand Stone B White Sand Stone , Plastering With Lime Surkhi Mortar Of 20Mm Thickness Including Preparation Of Mortar, Tamping, Curing, Prepared By Traditional Methods Including Mixing Of Gur, Tamarind Water, Dal Etc. As Per Tradition, The Work Is To Be Done With All Leads And Lifts, Surfaces To Be Plastered Shall Be Thoroughly Cleaned Of All Dust, Grease, Oil Etc. All Surfaces Should Be Kept Damp During The Progress Of Work. The Engineer-In-Charge Will Inspect And Approve All Preparatory Work. Curing To Be Done For 21 Days By Means Of Spraying , Roviding And Applying Lime Kara 1:2 (1 Lime: 2 Zikki Powder) Grinding Mortar With Grinding Mill/Manually On Lime Base, On All Flat Surface In Two Coats. First Coat Applying 3 To 4 M Thick And Curing Properly At Least 7 Days, Second Finishing Coat Done After 7 Days Of Previous Coat As Per Tradtional Practice (Thickness Not More Than 6Mm). , Providing Protective Coating Of Water Repellent Siloxane (Transparent In Color) Through Brush Or Spray Until Complete Impregnation Over Completely Cleaned And Dried Stone Or Plastered Surface To Reduce The Absorption Of Water , Taking Out Existing cement concrete Interlocking Paver Blocks From Footpath/ Central Verge, Including Removal Of Rubbish Etc., Disposal Of Unserviceable Material To The Dumping Ground, For Which Payment Shall Be Made Separately And Stacking Of Serviceable Material Within 50 Meter Lead As Per Direction Of Engineer-In-Charge. , Providing And Fixing Steel (White Powder Coated) Crescent Lock For Upvc Sliding Window/ Door With Necessary Screws Etc. Complete , Providing And Fixing Of Steel Banches , Providing And Fixing Glass Panes With Putty And Glazing Clips In Steel Door/ Windows/ Clerestory Window All Complete With 5.00Mm Thick Glass Panes Complete Job , Providing And Fixing Of Soap Dish , Providing And Fixing Inaugration Plate Including Writing Etc. Complete Job. , Carriage Of Materials By Mechanical Transport Including Loading / Unloading & Stacking Complete Sand For An Avg Distance Of 5 Kms , Carriage Of Materials By Mechanical Transport Including Loading / Unloading & Stacking Complete Stone Aggrigate For An Average Distance Of 7 Kms By Mt. , Carriage Of Materials By Mechanical Transport Including Loading / Unloading & Stacking Complete Brick For An Avg Distance Of 5 Kms , Electrification Items : Supply, Installation, Testing & Commissioning Of 5 Mtr Height Decorative Pole Made Of Galavnised Mild Steel Pipe Duly Polyurethane (Pu) Paint Coated With 1 Mtr. Long Double Arm Designer Bracket Is Made Of Round Tube Conforming To Is 1161. The Pole(Od Of 114.3Mm And Thickness-3.6Mm) With Bracket Is Given Pre-Treatment And Finished With Pu Paint Giving It A Pleasing Appearance And Antique Finish. Pole Shall Be Available To Hot Dip Galvanize The Tube Before Painting. Foundation Bolt Size Shall Be 20X600x4nos. With Base Plate Size 300X300x12mm. A Door Is Provided With Electrical Accessories (Connector, Bakelite Sheet And 6 annual periodical maintenance Single Pole Mcb, Cable Looping Termional For 4X4/6Sqmm Copper Cable). Aluminium Casting In Golden Ring Form At Bottom, Middle, Top Of The Pole. The Pole Will Be Supplied With Brackets And Luminaire Combinations To Suit The Requirement. Branding Name Shall Be Embossed At The Bottom Near Junction/Mcb Box. Sticker Not Allowed In The Form Of Company Branding. Pole Shall Be Supplied With Outdoor Post Top Luminaire Of 45 Watt Ip67 Mounted In Suspension Type Having An Approximate Size Of 460Mm Outer Diameter And 635Mm Height, Housing - Aluminium With Designer Steel Aesthetic Crown, Optical Grade Opal Injection Moulded/Clear Polycarbonate Diffuser And Graphite Grey Uv Resistant Colour,Constant Current Electronic, Driver Provided With High Voltage ,Open & Short Circuit Protection And Ambient Temperature -10C To +40C. Supply 150V- 240V Power Factor 0.95 ,Thd ≤ 20% Internal Surge Protection Of 4Kv With Following Specification Of Light Engine For 45W : 4500Lumens, Cct 3000K ±500 Cct ,Cri 70 And Lumen Maintenance Of L70 At 50000 Hours Ip 65 Connectors,Accessories Etc Complete With All Repects. Design Of Pole Should Be Such That It Should Maintains Proper Illumination On Both Side.(Analysis Attached) , Led Flood Light, Powder Coated Pressure Die Cast Aluminium (System Lumen Efficacy ≥105 120 Lm/Watt). Supplying, Installation, Testing & Commissioning Of Flood Light, Powder Coated Pressure Die Cast Aluminium Body With Built In Or Separate Driver As Per The Requirement With Driver Efficiency 85%, Input Voltage: Input Voltage: 140-270 Volt Ac, Frequency 50/60 Hz, Operating Temp Range -5 0C To 50 0C, Internal Surge Protection Of 5 Kv L,N,E As Per Iec 61000-4-5, Driver Efficiency 85%,Thd 10% As Per Iec 61000-3-2, P. F.≥0.95, Ip-66,Ik-10, Cri 70, Under Voltage And Over Voltage Protection, Emi-Emc As Per Cispr -15, Lenses For Beam Angle 30 Deg-120Deg As Per The Application And The Project Requirement., Suitable Tilt Able Fitting, Life Time (Led, Driver & Electrical Circuitry) Of Minimum 50000 Burning Hours With 70% Of Initial Lumen Maintained Till Life Ends As Per Lm80 Extrapolation Ies Tm-21-11 Report, Cct 3000°K / 4000°K / 5700°K /6500°K (As Per Ansi Bin) , Sdcm(Standard Deviation Color Matching) 5, Maximum Power Consumption Should Not More Than The Specified Rating And Fixture Shall Be Ofrelevant Bis Standard Complete In All Respect I/C External Connections With 1.5 Sq Mm Frls/Hffr, Pvc Insulated Copper Conductor Single Core Cable And Earthing Etc. As Required With Minimum 5 Year Oem Warranty. System Lumen Efficacy ≥105 120 Lm/Watt Output .Lm79 & Lm80 Test Report And All Testing Required For Led Fixtures As Per Bis Shall Be Submitted.. Shape Size And Cct Shall Be As Approved By Engineer-Incharge As Per Requirement. (Thermal Management: Heat Sink Of Aluminium Housing Such That Led Junction Temperature Shall Not Rise Above 90°C). 250 Watt , Led Linear Profile (Ac) Led Rgb/Rgbww/ Rgbnw/Rgba/Rgbw, Linear Profile / Wall Washer Luminaire For Façade Lighting With Aluminium Extruded/ Die Cast Housing With Inbuilt Driver Of Following Wattage. Wattage Per Meter 25W , Supply, Installation, Testing & Commissioning Of 1.1 Grade, 4Cx10 Sqmm Al. Armoured Xlpe Sheathed Cable Including Termination (Along With Lugs) , Providing And Fixing Of Gi Pipe 50 Mm Dia , Feeder Pillar 1 Phase 2 Wire, 415V, 1Nos Of 100 Amps Incoming Sp Mccbs Fitted With Outgoing 04 No 32 Amps Sp Mcbs For Service Connections, Distribution Service Pillar Suitable For Outdoor Installation , Made Out Of Crca Sheet Painted Through 7-Tank Process With Pu Painted Busbars 2P, Aluminium With Heat Shrinkable Sleeves And Adequate Capacities Complete With All Accessories 4 Way Distribution Service Pillar. Support Galvanised Angle Frame And Legs (40Mm X 40 Mm X 3Mm) For Distribution Feeder Pillar With Leg Height 1M With 0.3M In Soil Approx [email protected] Per Mtr, Earthing Complete By Gi Pipe 40 Mm Or Gi Rod 20Mm 2.5 Mtr Long Through Gi Strip.Cement Grouting For Support Angle Legs, Spares @ 3%, Erection Charges @10%, Overheads @ 5% (1.0% T&P 0.5% Storage And Handling , 3% Contingency And Safety Equipments, 0.5% Insurance) And Turnkey Factor @25% With Astronomical Timer. , Earthing With Copper Earth Plate 600Mm * 600Mm * 3 Mm Thick Including Accessories, And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Of 2.7 Meter Long Etc. With Charcoal/Coke And Salt As Required. , Wiring For Light Point/Fans Point/Exhaust Fan Point/ Call Bell Point With 1.5 Sq.Mm Frls/Hffr Pvc Insıslated Copper Conductor Single Core Cable In Surface/ Recessed Medium Class Pvc Conduit, With Modular Switch, Modular Plate, Suitable Gf Box And Earthing The Point With 1.5 Sq.Mm Frls/Hffr Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. Group-A , Add For Vetting Charges Consultency And Contigencies @ 2.5 %
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 2
Jammu And Kashmir View Result →
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 2
Maharashtra View Result →
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
Contract Date: Jun 09, 2026 Contract Value : 2.98 Lakh
Boards / Undertakings / PSU No of Bidders 3
31.
Drinking Water Supply and Sanitation #11254605 Technical Bid
Tender for Repair Of Road For Access To Farms From Sarkaspur To Nimboli Village
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 9
Maharashtra View Result →
Contract Date: Jun 30, 2026 Contract Value : 21.35 Lakh
Government Departments No of Bidders 2
Himachal Pradesh View Result →
33.
Water Resources and Irrigation #11228287 Price Bid
Tender for Repairs To 4 Cusec X 30 M Head Hc Pump Coupled With 60Hp Motor Of Unit-Ii Along With Allied Works At Lis Didwara. , Repairs To 4 Cusec X 30 M Discharge Horizontal Centrifugal Pump Of Unit No-Ii At Lis Didwara Coupled With 60 Hp Motor By Way Of Decoupling The Motor From The Pump Removal Of Nuts-Bolts From Coupling Pulley Set. Dismantling The Pump From The Base Frame,Suction Pipeline And Delivery Pipe Line. Shifting The Pump From Lis Didwara To Nearest Road Site By Head Load And Carriage Up To Work Shop In Mechanical Transport For Repair. Dismantling The Pump And Extracting The Damaged Internal Parts. Repairs To Impeller By Brazing Of Impeller Vanes And Finishing To Required Size, Providing And Fitting One No Impeller Wearing Ring. Repair To Pump Shaft By Remetalling At Wearout Place And Turning And Making New Thread,Re-Assembling The Same.Providing And Fitting Of Two New Bearings Of Appropriate Size As Required ,Neck Ring,Shaft Protection Sleeve, Check Nut, Nuts & Bolts, Fabrication Of New Gland Plate With Providing And Fitting Of 2 NoS New Gland Studs. Providing And Fitting Of Graphite Packing. Then Shifting Back Of The Pump To The Pump House After Carrying Out Necessary Repairs. Re-Installation Of Pump In Proper Alignment With 60 Hp Motor And Testing On Full Load At Site. Providing Of Extra 5 Kg Graphite Packing Of Size 10 Mm For Pump No.Ii And Pump No.Iii. Repairs To 250 Mm Diameter Sluice Valve Of Unit Iii By Way Of Dismantling At Workshop For Extraction Of Worn-Out Moving Internal Parts. Providing And Fitting Of Brass Machined And Thread New Stem Rod With Locking Nut. Providing And Fitting New Ci Gland Bracket Along With Gland Packing. Reassembling Of Sluice Valve Checking Operation For Smooth Alignments. Repairs To 250 Mm Reflux Valve By Way Of Dismantling Reflux Valve From Delivery Side Of Unit No Iii. The Job Involves Extraction Of Broken Flap Of Reflux Valve. Providing And Fitting Of New Flap With Locking Sheet. Replacement Of Hinge And Hinge Pin Of The Valve. Fitting Of The Valve On The Delivery Line With Providing And Fitting Of New Nuts And Bolts Along With Rubber Sheet To Prevent Leakage.Minor Repairs To 250Kva Electric Transformer At Site By Way Of Disconnecting The Incoming (Ht) Electrical Connection And Outgoing Electrical Connection I.E. Lt Connection. Then Dismantling The Top Cover Of The Transformer By Unscrewing The Required Nuts And Bolts To Have Access For Extraction Of Lt Bushes Rods.Topping Up Of New Transformer Oil 50 Liters In The Transformer. Refitting Of The Top Cover Of Transformer By Providing And Fitting Of New Gasket Sheet. Testing The Continuity Of Each Phase And Secure All Connection. Giving All The Incoming And Outgoing Electrical Connection After Cutting The Burnt Ends Of The Cable And providing and Fixing Of New Thimbles Of Appropriate Rating/ Size And Insulation. Complete Job Includes The Cost Of The Material, To & Fro Transportation Charges(Mechanical Carriage & Head Load) Of The Material, Skilled/Unskilled Labour Charges,Hiring Of Tools And Tackles Etc. Complete Job. Note:- The Tenderers Are Requested To Visit The Site And Quote The Rate As Per Site Conditions. Any Modifications/ Alterations Of The Job, Absolutely Necessary If Required At The Time Of Execution May Be Done As Per Actual Site Conditions. , Rebate On Old Parts
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Jammu And Kashmir View Result →
34.
Public Administrative Department #11221892 AOC
Tender For supply installation testing and commissioning Of Closed Circuit Television System Along With Required Accessories At Existing Dahisar West Skywalk At L.T Road In Rn Ward- 1 Supply, installtion , Testing & commissioning of 5MP Bullet CCTV Camera with 50 mtr. IR -Camera Type: Bullet | Image Sensor: 5MP CMOS Sensor | Resolution: 2592 × 1944 | Lens: 2.8mm / 3.6mm / 6mm | IR Range: 50m (IR Night Vision) | Video Compression: H.265 / H.264 | Frame Rate: 25/30 fps @ 5MP | Connectivity: Wired (PoE) | Power Supply: DC 12V / PoE (802.3af) | Weatherproof Rating: IP66 | Vandal Resistance: IK10 (Vandal-Resistant) | ONVIF Support: Yes (ONVIF Profile S/G/T) | SD Card Support: Yes (MicroSD up to 512GB) | Supported Protocols: TCP/IP, HTTP, HTTPS, RTSP, FTP, DHCP, NTP, SMTP, SNMP, UPnP, IPv4/IPv6 | Body Material: Full Metallic Body | Operating Temperature: -30°C to 60°C (-22°F to 140°F) | WDR (Wide Dynamic Range): Yes (120dB WDR) | DNR (Digital Noise Reduction): 3D DNR | Audio Support: Built-in Mic / External Audio Input | Smart Features: Motion/No Motion Detection, Tamper Detection, Trip/No Trip Detection, Object Intrusion/Zone Intrusion | Certifications: BIS, CE, IP67, IK10, CE, FCC, Cyber Security Compliance. Make - Matrix, CP Plus & Pramahikvision, Honeywell & Vivotek. 2 Supply, installtion, testing & commissioning of 16-Channel NVR 2 HDD- Number of Channels: 16 Channels (Supports 16 IP Cameras) | Supported Resolution: Up to 4K (8MP) per channel | Compression Format: H.265 / H.264 / H.265+ | Video Output: HDMI (4K) / VGA (1080p) | Recording Modes: Continuous, Motion Detection, Schedule, Alarm | Storage: 2 x SATA (Supports up to 20TB HDD) | Network Interface: 2 x RJ-45 10/100/1000Mbps Ethernet | ONVIF Support: Yes (ONVIF Profile S/G/T) | Remote Access: Mobile App (iOS/Android), Web Browser, PC Software | USB Ports: 2 x USB 2.0 / 3.0 for Backup & Mouse | Backup Options: USB, FTP, NAS | Audio Support: 1 x RCA Input / 1 x RCA Output | Smart Features: Motion Detection, View Tampering, Tripwire, Object Intrusion, Audio Exception, Missing Object, Suspicious Object | Power Supply: DC 12V / PoE Power Input | Operating Temperature: 0°C to 50°C (14°F to 131°F) | Network Protocols: TCP/IP, IPv4, IPv6, DHCP, PPPOE, DDNS, DNS, FTP, SMTP | Certifications: BIS, CE, FCC, RoHS, Cyber Security Compliance. Make - Matrix, CP Plus, Pramahikvision, Honeywell & VIvotek. 3 SITC of 8TB Storage (HDD) 4 SITC 42inches LED monitor 5 Router for ISDN 6 Video Management Software, Camera Operate and Manage by the single location. 7 Cat 6 Gigabyte 8 25 mm.- Only PVC Conduits 9 SITC of 9 inch Rack 10 SITC of 19 inch Rack 11 SITC of 2 KVA UPS true online 12 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire in 20mm Conduit 13 16/32 Amp. DP MCB 14 2/3 Pin Independent Plug (IP) 15 SITC of 16 ports 10/100/1000 with 2 combo ports PoE switch with installation 16 IP 42 Wall/column Mounted distribution board with one Nos of DP 32A MCB, 8 Noss 6/10A DP MCB as outgoing (18 way SPN DB) 17 40A to 63A DP MCB 18 ELCB with 30mA Sensitivity 25Amp. 2Pole 19 4C x 6.0 Sq.mm Alu armoured cable 20 4C x 16.0 Sq.mm Alu armoured cable 21 4C x 6.0 Sq.mm Alu armoured cable end termination 22 4C x 16.0 Sq.mm Alu armoured cable end termination 23 Bare G.I. Conductor size 10 SWG 24 SMCJB - 1414 25 CSMC for 2nd year after completing 1 year of DLP 26 CSMC for 3rd year 27 CSMC for 4th year
Contract Date: Mar 28, 2026 Contract Value : 37.00 Lakh
Local Bodies No of Bidders 3
Maharashtra View Result →
35.
Water Resources and Irrigation #11220406 Price Bid
Tender for Excavation In Dumped Stones Or Malba Including Stacking Of Serviceable And Unserviceable Material Separately And Disposal Of Unserviceable Material, Lead Up To 50 M And Lift Up To 1.5 M, Disposed Material To Be Neatly Dressed. , Earth Work In Excavation By Mechanical Means (Hydraulic Excavator) / Manual Means In Foundation Trenches Or Drains (Not Exceeding 1.5 M In Width Or 10 Sqm On Plan), Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soil As Directed, Within A Lead Of 50 M. All Kinds Of Soil. , Supplying Of Good Earth In Rough Excavation, Banking Excavated Earth In Layers Not Exceeding 20 Cm In Depth, Breaking Clods, Watering, Rolling Each Layer With ½ Tonne Roller, Or Wooden Or Steel Rammers, And Rolling Every 3Rd And Top-Most Layer With Power Roller Of Minimum 8 Tonnes And Dressing Up, In Embankments For Roads, Flood Banks, Marginal Banks, And Guide Banks For Filling Up Ground Depresssion Lead Upto 15 Km And Lift Upto 1.50 M. , Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level : 1:4:8 (1 Cement : 4 Coarse Sand (Zone-Iii) : 8 Graded Stone Aggregate 40 Mm Nominal Size) , Brick Work With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 In Foundation And Plinth In: Cement Mortar 1:6 (1 Cement : 6 Coarse Sand) , 15 Mm Cement Plaster On Rough Side Of Single Or Half Brick Wall Finished With A Floating Coat Of Neat Cement Of Mix :1:4 (1 Cement: 4 Fine Sand) , Providing And Laying Class Sn-8 Dwc Structed Wall Polyethylene Piping System (Pipe With Online/Offline Coupler And Elastomeric Sealing Ring) With Non Smooth External Annular Corrugated And Smooth Internal Surface (Double Wall) For Non Pressure Underground Sewerage And Drainage Application As Conforming To Is 16098 (Part-Ii): 2013, This Includes Jointing Of Pipes & Fittings With Solvent Cement,Thermostat Sealing, & Testing Of Joints Complete As Per Direction Of Engineer-In-Charge. 600 Mm Nominal Inner Dia Pipes , Constructing Brick Masonry Road Gully Chamber 45X45x77.5 Cm With Bricks In Cement Mortar 1:4 (1 Cement : 4 Coarse Sand ) With Precast Reinforced Cement Concrete Vertical Grating Complete As Per Standard Design : With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 , Constructing Brick Masonry Circular Manhole 1.22 M Internal Dia At Bottom And 0.56 M Dia At Top In Cement Mortar 1:4 (1 Cement :4 Coarse Sand) Inside Cement Plaster 12 Mm Thick With Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) Finished With A Floating Coat Of Neat Cement Foundation Concrete 1:3:6 (1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 40 Mm Nominal Size) And Making Necessary Channel In Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size) Finished With A Floating Coat Of Neat Cement, All Complete As Per Standard Design : 1.68 M Deep With Steel Fibre Reinforced Concrete Cover And Frame (Heavy Duty Hd-20 Grade Designation) 560 Mm Internal Diameter Conforming To I.S. 12592, Total Weight Of Cover And Frame To Be Not Less Than 182 Kg. Fixed In Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size) Including Centering, Shuttering All Complete. (Excavation, Foot Rests And 12 Mm Thick Cement Plaster At The External Surface Shall Be Paid For Separately) : With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5. , Providing And Laying Non-Pressure Np4 Class (Heavy Duty) Reinforced Cement Concrete Pipes Including Collars / Spigot Jointed With Stiff Mixture Of Cement Mortar In The Proportion Of 1:2 (1 Cement : 2 Fine Sand) Including Testing Of Joints Etc. Complete : 1000 Mm Dia. Reinforced Cement Concrete Pipes (Laying By Manual/Mechanical Means). , Providing And Laying Non-Pressure Np2 Class (Light Duty) Reinforced Cement Concrete Pipes With Collars Jointed With Stiff Mixture Of Cement Mortar In The Proportion Of 1:2 (1 Cement : 2 Fine Sand) Including Testing Of Joints Etc. Complete :300 Mm Dia. Reinforced Cement Concrete Pipe , Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement - All Work Up To Plinth Level : 1:2:4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size) , Providing And Laying In Position Ready Mixed Plain Cement Concrete, With Cement Content As Per Approved Design Mix And Manufactured In Fully Automatic Batching Plant And Transported To Site Of Work In Transit Mixer For All Leads, Having Continuous Agitated Mixer, Manufactured As Per Mix Design Of Specified Grade For Plain Cement Concrete Work, Including Pumping Of R.M.C. From Transit Mixer To Site Of Laying And Curing, Xcluding The Cost Of Centering, Shuttering And Finishing, Including Cost Of Curing, Admixtures In Recommended Proportions As Per Is : 9103 To Accelerate/Retard Setting Of Concrete, Improve Workability Without Impairing Strength And Durability As Per Direction Of The Engineer-In-Charge. Note : Excess/Less Cement Used Than Specified In This Item Is Payable/ Recoverable Separately M-10 Grade Plain Cement Concrete (Cement Content Considered @ 220 Kg/Cum) , Centering And Shuttering Including Strutting,Propping Etc.And Removal Of Form For:Foundations,Footings,Bases Of Columns,Etc.Formass Concrete , Centering And Shuttering Including Strutting,Propping Etc.And Removal Of Form For: Walls(Anythickness) Including Attached Pilasters,Butteresses, Plinth And String Courses Etc. , Centering And Shuttering Including Strutting,Propping Etc.And Removal Of Form For:Suspended Floors,Roofs,Landings,Balconies And Access Platform. , Providing And Laying In Position Machine Batched And Machine Mixed Design Mix M-25 Grade Cement Concrete For Reinforced Cement Concrete Work, Using Cement Content As Per Approved Design Mix, Including Pumping Of Concrete To Site Of Laying But Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement, Including Admixtures In Recommended Proportions As Per Is: 9103 To Accelerate, Retard Setting Of Concrete, Improve Workability Without Impairing Strength And Durability As Per Direction Of Engineer-In-Charge.(Note :- Cement Content Considered In This Item Is @ 330 Kg/Cum.Excess/ Less Cement Used As Per Design Mix Is Payable/Recoverable Separately).All Works Upto Plinth Level , Steel Reinforcement For R.C.C.Work Including Straightening,Cutting, Bending,Placing In Position And Bind In Gall Complete Upto Plinth Level. Thermo-Mechanically Treated Bars Of Grade Fe-500D Or More. , Cement Concrete Flooring 1:2:4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate)Finished With A Floating Coat Of Neat Cement,Including Cementslurry,But Excluding The Cost Of Nosingofsteps Etc.Complete. 40Mm Thick With 20Mm Nominal Size Stone Aggregate. , Providing And Placing In Position 100 Mm Thick Factory Made Machine Batched & Machine Mixed Precast Reinforced Cement Concrete Rectangular Covers On Drains Of Footpath Of Various Sizes, Of M-25 Grade Cement Concrete For Reinforced Cement Concrete Work, Including Cost Of Centering, Shuttering, Reinforcement Of 8 Mm Dia Tmt Bars Of Fe 500 Grade @ Maximum 100Mm C/C On Both Ways , Neat Cement Punning On Finished Surface, Properly Encased On All Edges With 1.6 Mm Thick , 100 Mm Wide Ms Sheet Duly Painted Over Priming Coat , Reinforcement To Be Welded At Edges With Ms Sheet And Providing 2 Nos. 12 Mm Dia Bar For Hooks Etc I/C Cost Of Cartage, All Leads & Lift, Handling At Site Etc. All Complete As Per Direction Of Engineer-In-Charge. , Providing And Laying Rmc Of M-30 Grade By Using Minimum 400 Kg. Of Cement (43 Grade Opc) Per Cum Of Concrete In Roads/Streets Manufactured In Automatic Rmc Plant Using Coarse Sand And Graded Stone Aggregate Of 20 Mm Nominal Size In Appropriate Proportion As Per Approved Design Criteria Including Transportation To Site In Transit Mixer, Including Cost Of Concrete To Improve Workability Wit Out Impairing Strength And Durability As Per Specification Including Spreading And Compacting Mechanically By Using Needle And Surface Vibrators, Leveling To Required Slops And Camber, Finishing By Contractor/ Expansion, Construction Of Cross/ Longitudinal Joints With Approved Joints Filler And Sealants, Etc. Complete As Per Direction Of Engineer-In-Charge(Cost Of Joint Filler & Sealants Shall Be Paid For Separately Under Relevant Item). Note: Cement Content Considered In M-30 Is @400 Kg/Cum. Rc Using Minimum Cement @400 Kg/Cum. Cement Concrete Manufactured In Automatic Batching Plant (Rc Plant) Including Transportation To Site In Transit Mixer. , Preparation And Consolidation Of Sub Grade With Power Road Roller Of 8 To 12 Tonne Capacity After Excavating Earth To An Average Of 22.5 Cm Depth, Dressing To Camber And Consolidating With Road Roller Including Making Good The Undulations Etc. And Re-Rolling The Sub Grade And Disposal Ofsurplus Earthwith Lead Upto 50 Metres. , Supplying And Stacking At Site. 90 Mm To 45 Mm Size Stone Aggregate , Supplying And Stacking At Site.63 Mm To 45 Mm Size Stone Aggregate , Supplying And Stacking At Site.53 Mm To 22.4 Mm Size Stone Aggregate , Supplying And Stacking At Site.Moorum , Supplying And Stacking At Site. Stone Screening 13.2 Mm Nominal Size (Typea) , Supplying And Stacking At Site.Stone Screening 11.2 Mm Nominal Size (Type B) , Laying, Spreading And Compacting Stone Aggregate Of Specified Sizes To Wbm Specifications In Uniform Thickness, Hand Picking, Rolling With 3 Wheeled Road/Vibratory Roller 8-10 Tonne Capacity In Stages To Proper Grade And Camber, Applying And Brooming Requisite Type Of Screening /Binding Material To Fill Up Interstices Of Coarse Aggregate, Watering And Compacting To The Required Density . , Providing And Applying Tack Coat Using Hot Straight Run Bitumen Of Grade Vg - 10, Including Heating The Bitumen, Spraying The Bitumen With Mechanically Operated Spray Unit Fitted On Bitumen Boiler, Cleaning And Preparing The Existing Road Surface As Per Specifications : On W.B.M. @ 0.75 Kg / Sqm , Providing And Laying Bituminous Macadam Using Crushed Stone Aggregates Of Specified Grading Premixed With Bituminous Binder, Transported To Site By Tippers, Laid Over A Previously Prepared Surface With Paver Finisher Equiped With Electronic Sensor To The Required Grade, Level And Alignment And Rolling With Smooth Wheeled, Vibratory And Tandem Rollers As Per Specifications To Achieve The Desired Compaction And Density, Complete As Per Specificatons And Directions Of Engineer-In-Charge. 50 To 100 Mm Average Compacted Thickness With Bitumen Of Grade Vg-30 @ 3.50% (Percentage By Weight Of Total Mix) Prepared In Batch Type Hot Mix Plant Of 100-120 Tph Capacity. , Providing And Applying Tack Coat Using Hot Straight Run Bitumen Of Grade Vg - 10, Including Heating The Bitumen, Spraying The Bitumen With Mechanically Operated Spray Unit Fitted On Bitumen Boiler, Cleaning And Preparing The Existing Road Surface As Per Specifications :On Bituminous Surface @ 0.50 Kg / Sqm , Providing And Laying Bituminous Concrete Using Crushed Stone Aggregates Of Specified Grading, Premixed With Bituminous Binder And Filler, Transporting The Hot Mix To Work Site By Tippers, Laying With Paver Finisher Equiped With Electronic Sensor To The Required Grade, Level And Alignment And Rolling With Smooth Wheeled, Vibratory And Tandem Rollers To Achieve The Desiredcompaction And Density As Per Specification, Complete And As Per Directions Of Engineer-In-Charge. 40/50 Mm Compacted Thickness With Bitumen Of Grade Vg-30 @ 5.5% (Percentage By Weight Of Total Mix) And Lime Filler @ 3% (Percentage By Weight Of Aggregate) Prepared In Batch Type Hot Mix Plant Of 100-120 Tph Capacity. , Filling Available Excavated Earth (Excluding Rock) In Trenches, Plinth, Sides Of Foundations Etc. In Layers Not Exceeding 20Cm In Depth, Consolidating Each Deposited Layer By Ramming Andwatering, Lead Up To 50 And For All Lift. , Disposal Of Building Rubbish / Malba / Similar Unserviceable, Dismantled Or Waste Materials By Mechanical Means, Including Loading, Transporting, Unloading To Approved Municipal Dumping Ground Or As Approved By Engineer-In-Charge, Beyond 50 M Initial Lead, For All Leads Including All Lifts Involved.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
36.
Water Resources and Irrigation #11220405 Price Bid
Tender for Excavation In Dumped Stones Or Malba Including Stacking Of Serviceable And Unserviceable Material Separately And Disposal Of Unserviceable Material, Lead Up To 50 M And Lift Up To 1.5 M, Disposed Material To Be Neatly Dressed. , Demolishing Cement Concrete Manually/ By Mechanical Means Including Disposal Of Material Within 50 Meters Lead As Per Direction Of Engineer- In - Charge. Nominal Concrete 1:3:6 Or Richer Mix (I/C Equivalent Design Mix). , Cutting Road And Marking Good The Same Including Supply Of Extra Quantities Of Materials I.E. Aggregate, Moorum Screening, Red Bajri And Labaur Required. Water Bound Macadam , Providing And Laying In Position Ready Mixed Plain Cement Concrete, With Cement Content As Per Approved Design Mix And Manufactured In Fully Automatic Batching Plant And Transported To Site Of Work In Transit Mixer For All Leads, Having Continuous Agitated Mixer, Manufactured As Per Mix Design Of Specified Grade For Plain Cement Concrete Work, Including Pumping Of R.M.C. From Transit Mixer To Site Of Laying And Curing, Xcluding The Cost Of Centering, Shuttering And Finishing, Including Cost Of Curing, Admixtures In Recommended Proportions As Per Is : 9103 To Accelerate/Retard Setting Of Concrete, Improve Workability Without Impairing Strength And Durability As Per Direction Of The Engineer-In-Charge. Note : Excess/Less Cement Used Than Specified In This Item Is Payable/ Recoverable Separately M-10 Grade Plain Cement Concrete (Cement Content Considered @ 220 Kg/Cum) , Providing And Laying Rmc Of M-25 Grade By Using Minimum 330 Kg. Of Cement (43 Grade Opc) Per Cum Of Concrete In Roads/Streets Manufactured In Automatic Rmc Plant Using Coarse Sand And Graded Stone Aggregate Of 20 Mm Nominal Size In Appropriate Proportion As Per Approved Design Criteria Including Transportation To Site In Transit Mixer, Including Cost Of Concrete To Improve Workability Wit Out Impairing Strength And Durability As Per Specification Including Spreading And Compacting Mechanically By Using Needle And Surface Vibrators, Leveling To Required Slops And Camber, Finishing By Contractor/ Expansion, Construction Of Cross/ Longitudinal Joints With Approved Joints Filler And Sealants, Etc. Complete As Per Direction Of Engineer-In-Charge(Cost Of Joint Filler & Sealants Shall Be Paid For Separately Under Relevant Item). Note : The Cement Considered In Rmc M-25 Is 330Kg/Cum. If Any Deviation In Quantity On Lower Side Is Observed Subject To Approval Of Job Mix Formula By Engineer-In-Charge, A Recovery Of Cement @ Rs. 10 Per Kg. Will Be Deducted. Rmc M-25 With Cement Content Less Than 300 Kg/Cum Shall Be Rejected. Excess Cement Used More Than 330 Kg/Cum Will Not Be Paid). , 6. Centering And Shuttering Including Strutting,Propping Etc.And Removal Of Form For: 6(A) Foundations,Footings,Bases Of Columns,Etc.Formass Concrete , 6(B) Walls(Anythickness) Including Attached Pilasters,Butteresses, Plinth And String Courses Etc. , 6 (C )Suspended Floors,Roofs,Landings,Balconies And Access Platform. , Providing And Laying In Position Machine Batched And Machine Mixed Design Mix M-25 Grade Cement Concrete For Reinforced Cement Concrete Work, Using Cement Content As Per Approved Design Mix, Including Pumping Of Concrete To Site Of Laying But Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement, Including Admixtures In Recommended Proportions As Per Is: 9103 To Accelerate, Retard Setting Of Concrete, Improve Workability Without Impairing Strength And Durability As Per Direction Of Engineer-In-Charge.(Note :- Cement Content Considered In This Item Is @ 330 Kg/Cum.Excess/ Less Cement Used As Per Design Mix Is Payable/Recoverable Separately).All Works Upto Plinth Level , Steel Reinforcement For R.C.C.Work Including Straightening,Cutting, Bending,Placing In Position And Bind In Gall Complete Upto Plinth Level. Thermo-Mechanically Treated Bars Of Grade Fe-500D Or More. , Cement Concrete Flooring 1:2:4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate)Finished With A Floating Coat Of Neat Cement,Including Cementslurry,But Excluding The Cost Of Nosingofsteps Etc.Complete. 40Mm Thick With 20Mm Nominal Size Stone Aggregate. , Providing And Laying Non-Pressure Np4 Class (Heavy Duty) Reinforced Cement Concrete Pipes Including Collars / Spigot Jointed With Stiff Mixture Of Cement Mortar In The Proportion Of 1:2 (1 Cement : 2 Fine Sand) Including Testing Of Joints Etc. Complete : 1000 Mm Dia. Reinforced Cement Concrete Pipes (Laying By Manual/Mechanical Means). , Providing And Laying Non-Pressure Np2 Class (Light Duty) Reinforced Cement Concrete Pipes With Collars Jointed With Stiff Mixture Of Cement Mortar In The Proportion Of 1:2 (1 Cement : 2 Fine Sand) Including Testing Of Joints Etc. Complete :300 Mm Dia. Reinforced Cement Concrete Pipe , Constructing Brick Masonry Circular Manhole 1.22 M Internal Dia At Bottom And 0.56 M Dia At Top In Cement Mortar 1:4 (1 Cement :4 Coarse Sand) Inside Cement Plaster 12 Mm Thick With Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) Finished With A Floating Coat Of Neat Cement Foundation Concrete 1:3:6 (1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 40 Mm Nominal Size) And Making Necessary Channel In Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size) Finished With A Floating Coat Of Neat Cement, All Complete As Per Standard Design : 1.68 M Deep With Steel Fibre Reinforced Concrete Cover And Frame (Heavy Duty Hd-20 Grade Designation) 560 Mm Internal Diameter Conforming To I.S. 12592, Total Weight Of Cover And Frame To Be Not Less Than 182 Kg. Fixed In Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size) Including Centering, Shuttering All Complete. (Excavation, Foot Rests And 12 Mm Thick Cement Plaster At The External Surface Shall Be Paid For Separately) : With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5. , Providing And Placing In Position 100 Mm Thick Factory Made Machine Batched & Machine Mixed Precast Reinforced Cement Concrete Rectangular Covers On Drains Of Footpath Of Various Sizes, Of M-25 Grade Cement Concrete For Reinforced Cement Concrete Work, Including Cost Of Centering, Shuttering, Reinforcement Of 8 Mm Dia Tmt Bars Of Fe 500 Grade @ Maximum 100Mm C/C On Both Ways , Neat Cement Punning On Finished Surface, Properly Encased On All Edges With 1.6 Mm Thick , 100 Mm Wide Ms Sheet Duly Painted Over Priming Coat , Reinforcement To Be Welded At Edges With Ms Sheet And Providing 2 Nos. 12 Mm Dia Bar For Hooks Etc I/C Cost Of Cartage, All Leads & Lift, Handling At Site Etc. All Complete As Per Direction Of Engineer-In-Charge. , Filling Available Excavated Earth (Excluding Rock) In Trenches, Plinth, Sides Of Foundations Etc. In Layers Not Exceeding 20Cm In Depth, Consolidatin Geachde Posited Layer By Ramming And Watering,Leadup To50mandliftupto1.5M. , Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement - All Work Up To Plinth Level : 1:2:4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size) , Disposal Of Building Rubbish / Malba / Similar Unserviceable, Dismantled Or Waste Materials By Mechanical Means, Including Loading, Transporting, Unloading To Approved Municipal Dumping Ground Or As Approved By Engineer-In-Charge, Beyond 50 M Initial Lead, For All Leads Including All Lifts Involved.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 5
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 3
Uttar Pradesh View Result →
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
Madhya Pradesh View Result →
40.
Defence #11200251 Technical Bid
Tender For Provision Of Certain Sanctioned Works Under Ge South Bathinda At Bathinda Mil Stn.- 1 Surface Excavation N.Exc (Not Exceeding) 30 Cm Deep And Averaging 15Cm Deep And Getting Out And Getting Out In Soft / Loose Soil Complete All As Specified & Directed. 2 Removing Excavated Material Exc 1.50 Km N Exc. 5 Km And Depositing Where Directed At A Level N Exc. 1.5 M Above The Starting Point Complete All As Specified And As Directed. 3 Excavation In Trenches Not Exceeding 1.5 Meter Wide And Not Exceeding 1.5 Meter Depth For Foundation Etc Or For Shafts , Wells, Cesspits, Manholes , Septic Tank, For Laying Of Cables , Laying Of Pipes Not Exceeding 10 Sqm On Plan And Not Exc 1.5 Meter Depth And Getting Out In Soft/Loose Soil Etc Complete All As Specified And As Directed By Engineer-In- Charge. 4 Material And Labour For Cement Concrete 1:4:8 , Type D-2 Using 40 Mm Graded Stone Aggregate As In Foundation Filling And Mass Concrete Complete All As Specified And As Directed By Engineer-In-Charge. 5 Material And Labour For Rcc M-25 (Design Mix) Using 20 Mm Graded Stone Aggregates As In Foundations, Including Rafts, Footings, Foundation Beams; Plinth Beams; Bases For Columns, Etc.; Basement Slabs, Under-Reamed Piles And Mass Concrete Complete All As Specified And As Directed By Engineer-In-Charge. Note : Reinforcement And Form Work Shall Be Measured And Paid For Separately Under Appropriate Item Of This Schedule. 6 Material And Labour For Rcc M-25 (Design Mix) Using 20 Mm Graded Stone Aggregates As In Columns, Pillars, Piers, Posts And Struts Complete All As Specified And As Directed By Engineer-In-Charge. Note : Reinforcement And Form Work Shall Be Measured And Paid For Separately Under Appropriate Item Of This Schedule. 7 Material And Labour For Rcc M-25 (Design Mix) Using 20 Mm Graded Stone Aggregates As In Beams, Cantilevers, Bressummers, Lintels Over 1.5 M Span And The Like Etc Complete All As Specified And As Directed By Engineer-In-Charge. Note : Reinforcement And Form Work Shall Be Measured And Paid For Separately Under Appropriate Item Of This Schedule. 8 Material And Labour For Rcc M-25 (Design Mix) Using 20Mm Graded Stone Aggregate As In Slabs Supported On Walls, Beams And Columns In Floors,Roofs, Landings, Balconies,Canopies, Deck Slabs And In Shelves And The Like Complete All As Specified And As Directed By Engineer-In-Charge.Note : Reinforcement And Form Work Shall Be Measured And Paid For Separately Under Appropriate Item Of This Schedule. 9 Material And Labour For Formwork Of Sides Of Concrete Foundations, Footings, Bases Of Columns, Raft And Raft Beams, Sides And Soffits (If Any) Of Foundation And Plinth Beams; And Similar Work; Vertical Or To Batter On Rough Finished Flat Surfaces Of Concrete Complete All As Specified And As Directed By Engineer-In-Charge. 10 Material And Labour For Formwork In Square,Reactangular Or Polygonal On Rough Finished Surface Of Concrete To Sides Of Pillars, Posts, Struts, Piers, Columns And Stanchions Complete All As Specified And As Directed By Engineer-In-Charge. 11 Material And Labour For Formwork To Sides And Soffits Of Floor Or Roof Beams, Beam Haunchings, Girders, Bressummers, Lintels, Cantilevers, Shelves Including Supports, Overhangs, Etc. Also Splays Between Floors And Beams, Etc. On Rough Finished Flat Surfaces Of Concrete Complete All As Specified And As Directed By Engineer-In-Charge. 12 Material And Labour For Formwork To Soffits Of Suspended Slabs Such As Roof Slab, Floor Slabs, Landings And Similar Work Not Exceeding 200 Mm Thick (Horizontal Or Sloping) On Rough Finished Flat Surfaces Of Concrete Complete All As Specified And As Directed By Engineer-In-Charge. 13 Material And Labour For Formwork To Edges Of Concrete Flats, Treads, Breaks In Floors,Window Cills, Concrete Rail Ings, Openings In Concrete Walls, Floor And Roofs Not Exceeding 20Cm Wide And Sides Of Rcc/Pcc Bands In Walls, Horizontal Or Sloping And Similar Work Exceeding 10 Cm But Not Exceeding 20Cm Wide On Rough Finished Surfaces Of Concrete Complete All As Specified And As Directed By Engineer-In-Charge. 14 Material And Labour For Mild Steel Tmt Bars 10Mm Dia And Over Cut To Length Bent To Shape, Required Including Cranking, Bending Spirally For Hoping For Columns, Hooking Ends And Binding With Mild Steel Wire (Annealed) Not Less Than 0.9Mm Dia Including Making Of Rungs, Handles Etc Complete All As Specified And As Directed By Engineer-In-Charge. (Note : Weight Of Binding Wire Shall Not Be Considered For Measurement And Payment Purpose.) 15 Material And Labour For Mild Steel Tmt Bars 6Mm To 8Mm Dia Cut To Length Bent To Shape, Required Including Cranking, Bending Spirally For Hoping For Columns, Hooking Ends And Binding With Mild Steel Wire (Annealed) Not Less Than 0.9Mm Dia Including Making Of Rungs, Handles Etc Complete All As Specified And As Directed By Engineer-In-Charge. (Note : Weight Of Binding Wire Shall Not Be Considered For Measurement And Payment Purpose.) 16 Demolition Of Brick Work Or Stone / Boulder Masonry, Built In Cement Mortar Or Cement Lime Mortar Including All Quoins, Arches, Pillars, Etc, In Any Description Complete All As Specified And As Directed By Engineer-In-Charge. 17 Material And Labour For Brick Work With Sub Class ‘B’ Bricks Straight Or Curved On Plan Exceeding 6.0M Mean Radius Built In Cement Mortar 1:6 Complete All As Specified And As Directed By Engineer-In-Charge. 18 Material And Labour For Brick Work With Fly Ash Bricks Straight Or Curved On Plan Exceeding 6.0M Mean Radius Built In Cement Mortar 1:6 Complete All As Specified And As Directed By Engineer-In-Charge. 19 Material And Labour Brick Work With Sub Class ‘B’ Old Size Burnt Clay Bricks Straight Or Curved On Plan Exceeding 6 Metre Mean Radius Built In Cement Mortar 1:6, Complete All As Specified And As Directed By Engineer-In-Charge . 20 Material And Labour For Brick Work With Fly Ash Old Size Bricks, Straight Or Curved On Plan To Any Radius In Half Brick Walls Built In Cement Mortar 1:4 Complete All As Specified And As Directed By Engineer-In-Charge. 21 Demolition Of Cement Concrete (Unreinforced) In Ground Floor And Paving Not Exceeding 15Cm Thickness Below Or Above Ground Level Of Any Description And In Any Position Including Removing Rubbish Material From Building And Thrown In Low Lying Empty Area (As Per Direcction Of Age/Je) At Any Distance Upto 500 Metres From The Site Complete All As Specified And As Directed By Engineer-In-Charge 22 Material & Labour For Cement Concrete 1:3:6 Type C-2 Using 40 Mm Graded Stone Aggregate For Foundations, Fillings & Mass Concrete Complete All As Specified And As Directed By Engineer-In-Charge. 23 Material And Labour For Cement Concrete (1:5:10), Type E-2 Using 40 Mm Graded Stone Aggregate As In Filling Of Sunken Floors Complete All As Specified And As Directed By Engineer-In-Charge. 24 Demolition Of Concrete Of Any Description And In Any Position Not Otherwise Specifically Provided Complete All As Specified And Directed. 25 Material And Labour For Waterproofing Treatment To Sunken Floor Using Acrylic Based Multipurpose Polymer. The Treatment Shall Be Carried Out As Per Manufactures Specification. The Treatment Shall Be Include Of The Following Elements Also: 1. Surface Preparation Of Substrate By Removing All Traces Of Contaminates, Loose And Friable Particles, Cement Laitance Oils And Grease, Water Repellent Coatings Etc2. Injection Grouting Using Cementitious Grout If Required. The Payment For Injection Grouting Shall Be Made Separately Etc3. Repair To The Substrate, Filling Of Blow Holes/Voids And Surface Leveling Using Appropriate Products Specified By The Manufacture.4. All Intersections Of Horizontal And Vertical Surface Should Be Profiled With A Mortar Fillet Of Minimum 25Mm X 25Mm.5. The Moisture Content Of The Substrate Shall Be Checked Before Application Of First Coat At Water Proof Coating At The Rate Of 200 G/M2 Followed Brush Topping At 450G/M2 Per Mm. The Second Coat Shall Be Reinforced With Glass Fabric Between The First And Second Coat.6. The Treatment Shall Be Protected By Application Of Polymer Modified Cement Mortar Of Thickness 10Mm Applied At The Rate Of 50G Per Mm.7. Tech Specification : Tensile Adhesion Strength 0.5N/Sqmm (As Bonding Slurry). 26 Material And Labour For Aerated Autoclaved Concrete (Aac) Blocks Work According To Indian Standard Specification Is:2185(Part-3)-1984 And Latest Revision Built In Cement And Sand Mortar 1:6 With Aerated Autoclaved Concrete (Aac) Blocks Straight Or Curver On Plan Exceeding 6Mtr Mean Radius As In Sunken Floor Complete All As Specified And And As Directed By Engineer-In-Charge. 27 Supply Only Integral Water Proofing Compound. 28 Removing Excavated Material As In All Kind Of Soils Not Exceeding 50M And Depositing Where Directed At A Level Not Exceeding 1.5M Above The Starting Point Complete All As Specified And As Directed By Engineer-In- Charge. 29 Returning Filling In Any Type Of Soil, Including Spreading, Levelling,Watering And Well Ramming In Layer Not Exceeding 25 Cm In Each Layer, Complete All As Specified And As Directed By Engineer-In- Charge. 30 Material And Labour For Sand Filling Under Floor Or In Foundation Including Spreading Levelling, Watering And Well Ramming In Layers Not Exc 25 Cmetc Complete All As Specified And As Directed By Engineer-In- Charge. Note: Sand Shall Be Approved By Ge. 31 Material And Labour For Hard Core Using Broken Stone Aggregate Of Gauge Not Exc. 63Mm, Deposited Spread And Leveled In Layers Not Exc. 150 Mm Thick, Watered And Rammed To A True Surface Complete All As Specified And As Directed By Engineer-In- Charge. 32 Material And Labour For 75 Mm Thick Cement Concrete 1:4:8 , Type D-2 Using 40 Mm Graded Stone Aggregate As In Sub Base Of Floor. Finished Even And Smooth Without Using Extra Cement Complete All As Specified And As Directed By Engineer-In-Charge. 33 Material And Labour For Rendering 10 Mm Thick In Cement Mortar 1:6 On Fair Faces Of Brick Work Or Concrete Surfaces Of Walls And Finishing The Surface Even & Fair Faces Without Using Extra Cement Complete All As Specified And As Directed By Engineer-In- Charge. 34 Material And Labour For Rendering 5 Mm Thick In Cement Mortar In (1:3) On Ceiling And Finishing The Surface Even & Smooth Without Using Extra Cement Complete All As Specified And Directed. 35 Material And Labour For 15Mm Thick Rendering In Cement Mortar 1:4 On Fair Faces Of Brick Work Or Concrete Surfaces Even And Smooth Without Using Extra Cement Complete All As Specified And As Directed By Engineer-In-Charge. 36 Material And Labour For 15Mm Thick Rendering In Cement Mortar 1:4 On Fair Faces Of Brick Work Or Concrete Surfaces And Finishing Fair & Even Mixed With Liquid Water Proofing Compound As Per ManufacturerS Instructions But Without Using Extra Cement Complete All As Specified And As Directed By Engineer-In-Charge. Note :- Liquid Water Proofing Compound Shall Be Measured And Paid Separately. 37 Supply And Fixing Chicken Wire Mesh ( Murga Jali ) In Cement Plaster Or Over Joints Of R.C.C And Brickwork Or As Per Site Requirement Of 24 Gauge & 12 Mm Mesh And 300 Mm Width For Construction Joints And Chasing In Brick Work For Electrical Conduits Or Water Supply Pipes And Pegs/Nails With Nailing Machine As Required Before Rendering / Plastering Etc. Complete As Per Site Requirement Complete All As Specified And As Directed By Engineer-In- Charge.Note: Rendering / Plastering Shall Be Measured And Paid Seperately Under Serial Item No. 5.00 Of ScheduleA Boq Here-In- Before. Nothing Shall Be Paid Extra On Account Of Rendering / Plastering In This Item. 38 Material And Labour For Applying Acrylic Wall Care Putty On Internal Surfaces And External Surfaces Of Walls/Ceilings/Soffits (Thickness Vary From 1.5 To 2.5 Mm As Required For Desired Smoothness And Leveling Of Surfaces In Two Or More Layers) By Using Ready Made Acrylic Wall Care Putty Including Sand Papering After Filling The Putty To Make Surface Smooth And Ready For Receiving Painting Etc Complete All As Specified And Directed By Engineer-In- Charge.Make Of Acrylic Wall Care Putty : As Descriped In List Of Makes/Manufacturers Under Appendix B Here-In-After.Notes : (I) The Prepared Surface After Wall Putty, The Contractor Will Inform To The Ge As Well As To The Engineer-In-Charge For Site Inspection Before Applying Further Finishes. Please Note That The Further Finishes Work Will Start Only After Approval Of The Prepared Surface From The Ge As Well As To The Engineer-In-Charge Through Site Order. (Ii)The Make Of Acrylic Wall Care Putty Shall Be As Per The Recommendation Of Manufacturer Of Paint. 39 Material And Labour For Preparation Of New Surfaces And Applying 02 Coats Of Interior Acrylic Emulsion Paint (Light Shade As Approved By Ge ) @ 10.00 Sq.M/ Litre / 2.00 Coats By Using Roller/Brush To Wall Surfaces Over With And Including One Coat Of Interior Acrylic Emulsion Primer @ 10.00 Sq.M / Litre / 1.00 Coat As Recommended For Under Coat By Manufacturer Of Interior Acrylic Emulsion By Using The Brands Of Interior Acrylic Emulsion Paint And Interior Acrylic Emulsion Primer As Descriped In List Of Makes/Manufacturers Under Appendix B Here-In-After Complete All As Specified And Directed By Engineer-In- Charge. 40 Material And Labour For Complete Removal Of Existing Treatment Of Any Type / Description From Wall / Rcc Surfaces / Ceiling / Chajjas / Roof Projections Etc With Mechanical Means / Grinder And Applying 01 Coat Of Exterior Emulsion Paint (Light Shade) With Highlighter Of Any Existing Shade @ 10 Sqm/Litre/1 Coat By Using Roller To External Walls / Rcc Surfaces/Soffits Of Chajjas / Roof Projections /Cantilevers/ Balcony Etc Surfaces Over Acrylic Thick Wall Care Putty On External Surfaces Of Walls / Ceiling / Soffits ( Thickness Vary From 1.5 To 2.5Mm As Required For Desired Smoothness And Levelling Of Surfaces In Two Or More Layers) By Using Ready Made Wall Care Putty Including Sand Papering After Filling The Putty To Make Surface Smooth And Ready For Receiving Painting Etc, Over Including A Coat Of Exterior Wall Primer @ 10 Sqm/Litre/1 Coat As Recommended For Under Coat By Manufacturer Of Exterior Emulsion By Using Following Brands Of Emulsion And Primer Including Removing The Vegetation Of Any Type And Description The Making The Surface Good Complete All As Specified And Directed. 41 Material And Labour For Preparation Of Old Surfaces And Applying 02 Coats Of Interior Acrylic Emulsion Paint (Light Shade As Approved By Ge ) @ 10.00 Sq.M/ Litre / 2.00 Coats By Using Roller/Brush To Wall Surfaces Over With And Including One Coat Of Interior Acrylic Emulsion Primer @ 10.00 Sq.M / Litre / 1.00 Coat As Recommended For Under Coat By Manufacturer Of Interior Acrylic Emulsion By Using The Brands Of Interior Acrylic Emulsion Paint And Interior Acrylic Emulsion Primer As Descriped In List Of Makes/Manufacturers Under Appendix B Here-In-After Complete All As Specified And Directed By Engineer-In- Charge. 42 M&L For Preparing Existing Treated Surfaces Of Ceiling Including Cornices And Applying Two Coats Of White Wash By Making The Lime Slaked At Site And Shall Be Mixed And Stirred With About Five Liters Of Water For 1 Kg Of Unslaked Lime To Make A Thin Cream. This Shall Be Allowed To Stand For A Period Of 24 Hours And Shall Then Be Screened Through Clean Coarse Cloth. 1 Kg Of Gum Dissolved In Hot Water Shall Be Added To Every One Cubic Meter Of Lime Cream. About 1.3 Kg Of Sodium Chloride Dissolved In Hot Water Shall Also Be Added For Every 10 Kg Of Lime For Making The Coating Hard And Rub-Resistant. Small Quantity Of Ultramarine Blue (Upto 3 Gm Per Kg Of Lime) Shall Also Be Added To The White Wash Solution And The Whole Solution Shall Be Stirred Thoroughly Before Use Complete All As Specified And As Directed By Engineer-In-Charge. 43 Material And Labour For Preparation Of New Surfaces And Applying 02 Coats Of Exterior Acrylic Emulsion Paint ( Shade As Approved By Ge) With Highlighter Of Any Approved Shade, @ 5.00 Sq.M / Litre / 2.00 Coats By Using Roller To External Walls / Rcc Surfaces / Soffits Of Chajjas / Roof Projections / Cantilevers / Balcony Etc. Surfaces Over With And Including One Coat Of Exterior Acrylic Emulsion Primer @ 11.00 Sq.M / Litre / 1.00 Coat As Recommended For Under Coat By Manufacturer Of Exterior Acrylic Emulsion By Using The Brands Of Exterior Acrylic Emulsion Paint And Exterior Acrylic Emulsion Primer As Descriped In List Of Makes/Manufacturers Under Appendix B Here-In-After Complete All As Specified And Directed By Engineer-In- Charge. 44 Material & Labour For Applying Two Or More Coats Of 100% Premium Acrylic Emulsion Paint Having Voc Less Than 50 Gm/Litre And Uv Resistance As Per Is 15489:2004, Alkali & Fungal Resistance, Dirt Resistance Interior Paint Of Required Shade (Company Depot Tinted) With Silicon Additives @ 1.43 Litre/ 10 Sqm Over And Including Priming Coat Of Exterior Primer Applied @ 0.90 Litre/ 10 Sqm Including A Coat Of Exterior Wall Primer @ 11 Sq.M/Litre/1 Coat As Recommended For Under Coat By Manufacturer Of Exterior Emulsion By Using Following Brands Of Emulsion And Primer Complete All As Specified And Directed. 45 Material And Labour For Preparation Of Old Surfaces And Applying 02 Coats Of Exterior Acrylic Emulsion Paint ( Shade As Approved By Ge) With Highlighter Of Any Approved Shade, @ 5.00 Sq.M / Litre / 2.00 Coats By Using Roller To External Walls / Rcc Surfaces / Soffits Of Chajjas / Roof Projections / Cantilevers / Balcony Etc. Surfaces Over With And Including One Coat Of Exterior Acrylic Emulsion Primer @ 11.00 Sq.M / Litre / 1.00 Coat As Recommended For Under Coat By Manufacturer Of Exterior Acrylic Emulsion By Using The Brands Of Exterior Acrylic Emulsion Paint And Exterior Acrylic Emulsion Primer As Descriped In List Of Makes/Manufacturers Under Appendix B Here-In-After Complete All As Specified And Directed By Engineer-In- Charge. 46 Material And Labour For Complete Removal Of Existing Treatment Of Any Type / Description From Wall / Rcc Surfaces / Ceiling / Chajjas / Roof Projections Etc With Mechanical Means / Grinder And Applying One Coat Of Exterior Emulsion Paint (Light Shade) With Highlighter Of Any Approved Shade @ 5 Sqm/Litre/2 Coats By Using Roller To External Walls / Rcc Surfaces/Soffits Of Chajjas / Roof Projections /Cantilevers/ Balcony Etc Surfaces Over & Including A Coat Of Exterior Wall Primer @ 11 Sqm/Litre/1 Coat Over Acrylic Thick Wall Care Putty On External Surfaces Of Walls / Ceiling / Soffits (Thickness Vary From 1.5 To 2.5Mm As Required For Desired Smoothness And Levelling Of Surfaces In Two Or More Layers) By Using Ready Made Wall Care Putty Including Sand Papering After Filling The Putty To Make Surface Smooth And Ready For Receiving Painting Etc As Recommended For Under Coat By Manufacturer Of Exterior Emulsion By Using Following Brands Of Emulsion And Primer Complete All As Specified And Directed.Note For Item No 5 To 8 :- (A) The Prepared Surface After Wall Putty, The Contractor Will Inform To The Ge As Well As To The Engineer-In-Charge For Site Inspection Before Applying Further Finishes. Please Note That The Further Finishes Work Will Start Only After Approval Of The Prepared Surface From The Ge As Well As To The Engineer-In-Charge Through Site Order. 47 Material And Labour For For Preparing New Plastered Surfaces Of Ceilings And Applying Three Coats Of White Wash By Making The Lime Slaked At Site And Shall Be Mixed And Stirred With About Five Liters Of Water For 1 Kg Of Unslaked Lime To Make A Thin Cream. This Shall Be Allowed To Stand For A Period Of 24 Hours And Shall Then Be Screened Through Clean Coarse Cloth. 1 Kg Of Gum Dissolved In Hot Water Shall Be Added To Every One Cubic Meter Of Lime Cream. About 1.3 Kg Of Sodium Chloride Dissolved In Hot Water Shall Also Be Added For Every 10 Kg Of Lime For Making The Coating Hard And Rub-Resistant. Small Quantity Of Ultramarine Blue (Upto 3 Gm Per Kg Of Lime) Shall Also Be Added To The Last Two Coats Of White Wash Solution And The Whole Solution Shall Be Stirred Thoroughly Before Use Complete All As Specified And Directed By Engineer-In- Charge. 48 Material And Labour For Applying Three Coats Of White Wash On Newly Plastered Or Unplastered Ceiling Surfaces Including Preparation Of Surfaces, Complete All As Specified And Directed 49 Taking Down Chowkats Or Frames With Shutters (Without Taking Off Shutters From The Frames) Area Not Exc 1.5 Sqm Each As Doors, Windows And Ventilators And Removal From Site Complete All As Specified And Directed. 50 Taking Down Chowkats Or Frames With Shutters (Without Taking Off Shutters From The Frame) Exc 1.5 Sqm But Not Exc 4 Sqm Each Each As Doors, Windows And Ventilators And Removal From Site Complete All As Specified And Directed. 51 Supply & Fixing Factory Made Single Extruded Wpc ( Wood Polymer Composite ) Solid Door Frame / Chowkhat Of Size 45Mm X 70 Mm Comprising Of Virgin Polymer Of K Value 58-60 (Suspension Grade ), Calcium Carbonate And Nautral Fibers ( Wood Powder / Rice Husk / Wheat Husk ) And Non Toxic Additives (Maximum Toxcity Index Of 12 For 100 Gms ) Fabricated With Miter Joints After Applying Pvc Solvant Cement And Screwed With Full Body Threaded Star Headed Ss Screws Having Minimum Frame Density Of 750 Kg /Cum And Screw Withdrawl Strength Of 2200 N (Face ) & 1100 N (Edge) Minimum Compressive Strength Of 58 N /Sqmm Modulus Of Elasticity 900 N/Sqmm And Resisitence To Spread Of Flame Of Class A Category With Property Of Being Termite / Borer Proof , Water Moisture Proof And Fire Retaident And Fixed In Position With And Including Ms Hold Fast Lugs / Ss Dash Fastner Of Required Dia And Length With And Including Supply And Fixing (03 Nos Per Frame ) 100 Mm Long Ss Butt Hinges Complete All As Specified And As Directed By Engineer-In- Charge. 52 Supply & Fixing Factory Made Single Extruded Wpc ( Wood Polymer Composite ) Solid Door Frame / Chowkhat With Double Rebate Of Size 65Mm X 125 Mm Comprising Of Virgin Polymer Of K Value 58-60 (Suspension Grade ), Calcium Carbonate And Nautral Fibers ( Wood Powder / Rice Husk / Wheat Husk ) And Non Toxic Additives (Maximum Toxcity Index Of 12 For 100 Gms ) Fabricated With Miter Joints After Applying Pvc Solvant Cement And Screwed With Full Body Threaded Star Headed Ss Screws Having Minimum Frame Density Of 750 Kg /Cum And Screw Withdrawl Strength Of 2200 N (Face ) & 1100 N (Edge) Minimum Compressive Strength Of 58 N /Sqmm Modulus Of Elasticity 900 N/Sqmm And Resisitence To Spread Of Flame Of Class A Category With Property Of Being Termite / Borer Proof , Water Moisture Proof And Fire Retaident And Fixed In Position With And Including Ms Hold Fast Lugs / Ss Dash Fastner Of Required Dia And Length With And Including Supply And Fixing (03 Nos Per Frame ) 100 Mm Long Ss Butt Hinges Complete All As Specified And As Directed By Engineer-In- Charge. 53 Supply & Fixing Factory Made Single Extruded Wpc ( Wood Polymer Composite ) Solid Plain Flush Door Shutter Of 30 Mm Thick , Size Comprising Of Virgin Polymer Of K Value 58-60 (Suspension Grade ), Calcium Carbonate And Nautral Fibers ( Wood Powder / Rice Husk / Wheat Husk ) And Non Toxic Additives (Maximum Toxcity Index Of 12 For 100 Gms ) Having Minimum Density Of 650 Kg /Cum And Screw Withdrawl Strength Of 1800 N (Face ) & 900 N (Edge) Minimum Compressive Strength Of 50 N /Sqmm Modulus Of Elasticity 850N/Sqmm And Resisitence To Spread Of Flame Of Class A Category With Property Of Being Termite / Borer Proof , Water Moisture Proof And Fire Retardant And With And Including Supply & Fixing Of 02 Nos (Per Leaf) Ss 150Mm Long Tower Bolt, Supply & Fixing Of 02 Nos (Per Door) Ss 300Mm Long Sliding Bolt With And Including Supply & Fixing Of 02 Nos (Per Leaf) Stainless Steel 150Mm Long Handle Complete All Specified And Directed By Engineer -In-Charge. 54 Supply & Fixing Factory Made Single Extruded Wpc ( Wood Polymer Composite ) Solid Decorative Flush Door Shutter Of 30 Mm Thick , Size Comprising Of Virgin Polymer Of K Value 58-60 (Suspension Grade ), Calcium Carbonate And Nautral Fibers ( Wood Powder / Rice Husk / Wheat Husk ) And Non Toxic Additives (Maximum Toxcity Index Of 12 For 100 Gms ) Having Minimum Density Of 650 Kg /Cum And Screw Withdrawl Strength Of 1800 N (Face ) & 900 N (Edge) Minimum Compressive Strength Of 50 N /Sqmm Modulus Of Elasticity 850N/Sqmm And Resisitence To Spread Of Flame Of Class A Category With Property Of Being Termite / Borer Proof , Water Moisture Proof And Fire Retardant And With And Including Supply & Fixing Of 02 Nos (Per Leaf) Ss 150Mm Long Tower Bolt, Supply & Fixing Of 02 Nos (Per Door) Ss 300Mm Long Sliding Bolt With And Including Supply & Fixing Of 02 Nos (Per Leaf) Stainless Steel 150Mm Long Handle Complete All Specified And Directed By Engineer -In-Charge. 55 Supply & Fixing Factory Made 30Mm Thick Solid Wpc ( Wood Polymer Composite ) Wiremesh Door Shutter Of Required Size Comprising Of Virgin Pvc Resin Of K Value 57-60 ( Suspension Rade ), Calcium Carbonate And Natural Fibers ( Wood Powders/ Rice Husk/ Wheat Husk ) And Non Toxic Additives, Made From Extrusion Process Wpc Foam Sheet Single Extruded ( Inner ) With Having Minimum Density Not Less Than 650 Kg/Cum , Having Good Screw Holding Capacity ( Screw Withdrawal Strength Of 2000 N ( Face ) & 1100 N ( Edge ), Minimum Compressive Of 50 N/Mm2, Modulus Of Elasticity 850N/Mm2 And Resistance Of Spread Of Flame Of Class A Category With Property Of Being Termite/ Borer Free.Water/ Moisture Proof And Fire Retardant. Pvc Foil Of Minimum 14 Microns Thick Of Approved Design Pasted On Both Faces Of Shutter For Fixing Mosquito Mesh And Xtn Aluminium Mesh Together On Panel Area Of Door Except Stiles And Rails To Be Panelled With And Including Mesh With Self Tapping Round Headed Scresws At Required Distance, Screws And Edges Covered With Feathered Pvc Edge Beading All Around Of Mesh And Fixing Stainless Steel Butt Hinges Of Required Size With Necessary Full Body Threaded Star Headed Counter Sunk Ss Screws With And Including 03 Nos Door Stainless Steel Butt Hings 100Mm Long With Stainlessd Steel Screws For Each , 02 Nos Stainless Steel Barrel Tower Bolts Of Extrude Section, 150Mm Long (Isi Marked), 2 Nos Stainles Steel Handles, 125 Mm Long, (Isi Marked) , 01 No. Of Helical Door Spring Of 300 Mm Length Complete All As Specified And As Directed By Engineer-In-Charge. Note: 1. Material Test Certificate Of All The Items And Authentication Should Be Compulsory Provided By The Manufacturing Company 2. The Rate Of 03 Nos Door Stainless Steel Butt Hings 100Mm Long With Stainlessd Steel Screws For Each , 02 Nos Stainless Steel Barrel Tower Bolts Of Extrude Section, 150Mm Long (Isi Marked), 2 Nos Stainles Steel Handles, 125 Mm Long, (Isi Marked) , 01No. Of Helical Door Spring Of 300 Mm Length Is Inclusive In This Item And Nothing Shall Be Paid Extra On This Item..3. The Rate Of Mosquito Mesh And Xtn Aluminium Mesh Is Included In This Item And Nothing Shall Be Paid Extra On This Account. 56 Supply And Fixing Factory Made Upvc White Colour Casement (Openable) Window (Area Exceeding 1.00 Sqm But Not Exceeding 2.00 Sqm Each) Made Of Extruded Profiles With Wall Thickness Of 2.3Mm ( + – 0.2Mm). Window Profile With Hollow Section With Multi Chamber, Frame (60Mm X 58Mm), Sash (60Mm X 73Mm), T Profile (One Vertical Length In Between Two Shutters) (60Mm X 74Mm), Glazing Bead (35Mm X 20Mm) Will Be Mitered Cut And Fusion Welded At All Corners, Including Drilling Of Holes For Fixing Hardware And Drainage Of Water Etc., Making Arrangement For Fixing Of Hardware. Epdm Gasket 1.2 +– 0.2Mm Thick, Galvanized Steel Frame (28Mm X 21.5Mm), Sash (31Mm X 27.5Mm). T Profile (27Mm X 17Mm) To Be Inserted In Required Profile, Frame Will Be Fixed To The Wall With 8 Mm X 100Mm Long Fasteners. Hardware: [Casement Handle Made Of Zinc Alloyed (White Powder Coated), But Hinges OfZinc Alloyed (White Powder Coated), Transmission Gear Made Of Mild Steel With Multi Point Locking System] And 5Mm Thick Glazing With Selected Quality Glass.(Note: The Unit Rate Quoted By Contractor Excludes Cost Of Glass And Includes All Other Connected Accessories. Net Opening Will Be Measured For Payment Purpose.) 57 Material And Labour For 75 Mm Thick Pcc 1:3:6 , Type C-1 Using 20 Mm Graded Stone Aggregate As In Plinth Protection, Finishing The Surface Even And Smooth Without Using Extra Cement Complete All As Specified And As Directed By Engineer-In- Charge. 58 Material And Labour For 75 Mm Thick Pcc 1:3:6 , Type C-2 Using 40 Mm Graded Stone Aggregate As In Plinth Protection, Finishing The Surface Even And Smooth Without Using Extra Cement Complete All As Specified And As Directed By Engineer-In- Charge. 59 Demolition And Breaking Up Drain Pipes (Salt Glazed Ware, Ac Or Reinforced Concrete)Of Any Dia Set In Cement Laid In Trenches Incl All Fittings & Accessorises Complete All As Specified And As Directed By Engineer-In- Charge. 60 Supply & Fixing For 4 Mm Thick, Sheet Glass Ordinary Quality And Glazing With Oil Putty In Square Not Exceeding 0.5 Sqm In Each Pane Complete All As Specified And As Directed By Engineer-In- Charge. 61 Supply & Fixing 4.0 Mm Thick Figured Glass Pin Head Type And Glazing With Oil Putty In Square N.Exc 0.5 Sqm In Each Pane Complete All As Specified And Directed 62 Supply & Fixing 5.5 Mm Thick, Sheet Glass Ordinary Quality Not Exceeding 0.50 Sqm In Each Pane Complete All As Specified And As Directed By Engineer-In- Charge. 63 Supply & Fixing 5.5 Mm Thick, Sheet Glass Ordinary Quality Exceeding 0.50 Sqm In Each Pane Complete All As Specified And As Directed By Engineer-In- Charge. 64 Material And Labour For Providing And Fixing Aluminium Work With Polyester Powder Coated Aluminium ( Minimum Thickness Of Polyester Powder Coating 50 Micron For Doors, Windows, Ventilators And Partitions With Extruded Built Up Standard Tubular Sections/Appropriate Z Sections And Other Sections Of Approved Make Conformikng To Is:733 And Is :1285, Fixing With Dash Fasteners Of Required Dia And Size,Including Necessary Filling Up The Gaps At Junctions I.E At Top , Bottom And Sides With Required Epdm Rubber / Neoprene Gasket Etc. Aluminium Sections Shall Be Smooth , Rust Free, Straight, Mitred And Jointed Mechanically Wherever Required Including Aluminium Cleat Angle, Aluminium Snap Beading For Glazing/ Paneling , C.P. Brass/ Stainless Steel Screws, All Complete All As Specified And Directed By Engineer-In-Charge .Note :- (I) Weight Of Aluminium Sections , Aluminium Cleat Angles , Aluminium Butt Hinges, Aluminium Handles , Aluminium Tower Bolts , Aluminium Peg Stays & Aluminium Snap Beading Shall Be Physically Ascertained Through A Board Of Officers Convened By Ge And Payment Shall Be Made Only After Ascertaining The Actual Weight Of Aluminium At Site.(Ii) The Rate Of Material And Labour For Providing The Epdm Rubber, Neoprene Gasket , C.P. Brass / Stainless Steel Screws Are Included In This Item And Nothing Shall Be Paid Extra On This Account. (Iii) During Considering The Weight Of Aluminium Sections , Aluminium Cleat Angles , Aluminium Butt Hinges, Aluminium Handles , Aluminium Tower Bolts , Aluminium Peg Stays & Aluminium Snap Beading , The Weight Of Epdm Rubber, Neoprene Gasket , C.P. Brass/ Stainless Steel Screws Shall Not Be Considered For Measurments And Payments. Only The Weight Of The Aluminium Sections , Aluminium Cleat Angles, Aluminium Butt Hinges, Aluminium Handles , Aluminium Tower Bolts , Aluminium Peg Stays & Aluminium Snap Beading Shall Be Considered And Measurment And Payment Shall Be Made Accourdingly.(Iv) During The Weight Of Aluminium Sections , Aluminium Cleat Angles , Aluminium Butt Hinges, Aluminium Handles , Aluminium Tower Bolts , Aluminium Peg Stays & Aluminium Snap Beading ,The Weight Of Polyester Powder Coating 50 Micron Shall Not Be Considered For Weight But The Rate Of Material And Labour For Providing Polyester Powder Coating 50 Micron Is Included In This Item And Nothing Shall Be Paid Extra On This Account. (V) Glazing /Paneling And Wire Mesh Shall Be Measured And Paid Seperately. (V)The Board Shall Be Duly Countersigned By Ge Shall Enclosed With Final Bill . 65 Supply & Fixing Stainless Steel Wire Cloth 0.36 Mm Nominal Dia Of Wire And Average Width Of Aperture 1.4Mm And Fixed With Tinned Tacks To Stainless Steel Wire Staple Complete All As Specified And As Directed By Engineer-In-Charge. 66 Supply & Fixing Galvanised Ms Wire Cloth 0.36 Mm Nominal Dia Of Wire And Average Width Of Aperture 1.4Mm And Fixed With Tinned Tacks To Galvanised Ms Wire Staple Complete All As Specified And As Directed By Engineer-In-Charge. 67 Material And Labour For Providing And Laying Premium (1St Quality) Straight Edge,Stain Free, Glooss Finish, Square Marbonite Double Charged Vitrified Tiles Size In 600Mm X 600Mm X 9Mm To 10Mm Thick As In Floors Etc. Shade As Approved By Ge , Set And Jointed With Using Spacer And Approved High Polymer Modified, Grey Cement-Based Tile Adhesive Suitable For Fixing Medium Format Tile/Stone In Walls/Floor Conforms To Is 15477 : 2019 Type 2T “Adhesives For Use With Ceramic, Mosaic And Stone Tiles” Conforms To En 12004: 2017 And Is A Normal Cementitious Adhesives (C1) With Slip Resistance (T) Of Class C1 And Necessary Grouting As Per Manufacturer’S Instruction, Completed All As Specified And Directed By Engineer-In-Charge. 68 Supply And Fixing Anodised Aluminium Snap Grid Frame Work For False Ceiling 605Mm X 605 Mm Etc Complete All As Specified And As Directed By Engineer-In-Charge. 69 Supply And Fixing False Ceiling At All Heights With Grg (Glass Fibre With Reinforced Gypsum) False Ceiling Tiles Of Size 595 X 595 Mm Of Approved Tecture Design And Patterns Having Moisture Content Less Than 2% Humidity Resistance Of 99%, Nrc 0.50 To 0.75 As Per Is 8225:1987, Noncombustible As Per Bs 476 (Part 4)- 1970 And Light Reflectance Of 85%D (Minimum) To Be Laid In True Horizontal Level Suspended On Inter Locking Metal T-Grid Of Hot Dipped Galvanisezed Iron Section Of 0.33Mm Thick (Galvanized @ 120 Grams Per Sqm Including Both Sides) Comprising Of Main T Runners Of Size 15 X 32 Mm Of Length 3000 Mm, Cross-T Of Size 15 X 32Mm Of Length 1200Mm And Secondary Intermediate Cross T Of Size 15 X 32 Mm Of Length 600Mm To Form Grid Module Of Size 600 X 600Mm, Suspended From Ceiling Using Galvanised Mild Steel Items (Galvanizing @ 80 Grams Per Sqm) I.E 50 Mm Long, 8 Mm Outer Diameter M-6 Dash Fasteners, 6Mm Dia Fully Threaded Hanger Rod Upto 1000 Mm Length And L Shape Level Adjuster Of Size 85 X 25 X 2Mm. Galvanized Iron Perimeter Wall Angle Of Size 24 X 24 X 0.40Mm Of Length 3000 Mm To Be Fixed On Periphery Wall I Partition With Help Of Plastic Rawl Plugs At 450 Tiles Fully Center To Center And 40Mm Long Dry Wall Wodd Screws. The Work Shall Be Carried Out As Per Specifications, Drawing And As Per Directions Of The Engineer-In-Charge. 70 Material And Labour Anodised Aluminium Frame For Doors, Windows, Ventilators With One Or More Rebates Including Joining Cleat For Fixing Etc. Omplete All As Specified And As Directed By Engineer-In-Charge. 71 Material And Labour For Providing And Fixing Aluminium Work With Polyester Powder Coated Aluminium ( Minimum Thickness Of Polyester Powder Coating 50 Micron For Doors, Windows, Ventilators And Partitions With Extruded Built Up Standard Tubular Sections/Appropriate Z Sections And Other Sections Of Approved Make Conformikng To Is:733 And Is :1285, Fixing With Dash Fasteners Of Required Dia And Size,Including Necessary Filling Up The Gaps At Junctions I.E At Top , Bottom And Sides With Required Epdm Rubber / Neoprene Gasket Etc. Aluminium Sections Shall Be Smooth , Rust Free, Straight, Mitred And Jointed Mechanically Wherever Required Including Aluminium Cleat Angle, Aluminium Snap Beading For Glazing/ Paneling , C.P. Brass/ Stainless Steel Screws, All Complete All As Specified And Directed By Engineer-In-Charge .Note :- (I) Weight Of Aluminium Sections , Aluminium Cleat Angles & Aluminium Snap Beading Shall Be Physically Ascertained Through A Board Of Officers Convened By Ge And Payment Shall Be Made Only After Ascertaining The Actual Weight Of Aluminium At Site.(Ii) The Rate Of Material And Labour For Providing The Epdm Rubber, Neoprene Gasket , C.P. Brass / Stainless Steel Screws Are Included In This Item And Nothing Shall Be Paid Extra On This Account. (Iii) During Considering The Weight Of Aluminium Sections , Aluminium Cleat Angles & Aluminium Snap Beading , The Weight Of Epdm Rubber, Neoprene Gasket , C.P. Brass/ Stainless Steel Screws Shall Not Be Considered For Measurments And Payments. Only The Weight Of The Aluminium Sections , Aluminium Cleat Angles & Aluminium Snap Beading Shall Be Considered And Measurment And Payment Shall Be Made Accordingly.(Iv) During The Weight Of Aluminium Sections , Aluminium Cleat Angles & Aluminium Snap Beading ,The Weight Of Polyester Powder Coating 50 Micron Shall Not Be Considered For Weight But The Rate Of Material And Labour For Providing Polyester Powder Coating 50 Micron Is Included In This Item And Nothing Shall Be Paid Extra On This Account. (V) Powder Coated Butt Hinges, Aluminium Handles, Aluminium Tower Bolts & Aluminium Peg Stays Shall Be Measured And Paid Seperately Under Respective Itmes Of ScheduleA Boq.(V) Glazing /Paneling And Wire Mesh Shall Be Measured And Paid Seperately. (Vi)The Board Shall Be Duly Countersigned By Ge Shall Enclosed With Final Bill 72 Material And Labour Anodised Aluminium Grill (Anodised Transparent Of Dyed To Required Shade According To Is: 1868 With Minimum Anodic Coating Of Grade Ac 15) Of Approved Design/Pattern, With Approved Standard Section And Fixed To The Existing Window Frame With C.P. Brass/Stainless Steel Screws @ 200 Mm Centre To Centre, Including Cutting The Grill To Proper Opening Size For Fixing And Operation Of Handles And Fixing Approved Anodised Aluminium Standard Section Around The Opening, All Complete As Per Requirement And Direction Of Engineer-In-Charge. 73 Taking Up Or Down Galvanised Steel Water Tubing (Gi Pipe) 15Mm Bore Including Fitting/Connection From Wall/Ceiling/Floor/Concealed Etc. Complete All As Specified And As Directed By Engineer-In-Charge. 74 Taking Up Or Down Galvanised Steel Water Tubing (Gi Pipe) 20Mm Bore Including Fitting/Connection From Wall/Ceiling/Floor/Concealed Etc. Complete All As Specified And As Directed By Engineer-In-Charge. 75 Supply And Fixing 16 Mm Bore Cpvc Pipe Sdr 11 With And Including Cpvc Sdr 11 Fittings And Fixed To Walls & Ceilings Or Laid In Floors, Complete Complete All As Specified And As Directed By Engineer-In-Charge 76 Supply And Fixing 20 Mm Bore Cpvc Pipe Sdr 11And Plain Cpvc Sdr 11 Fitting With All Fitting And Fixed To Walls & Ceilings Or Laid In Floors, Including Taking Down Unservicable Existing Gi Tubing Of 20Mm Bore And Fittings Complete Complete All As Specified And As Directed By Engineer-In-Charge. 77 Supply And Fixing 25 Mm Bore Cpvc Pipe Sdr 11And Plain Cpvc Sdr 11 Fitting With All Fitting And Fixed To Walls & Ceilings Or Laid In Floors, Including Taking Down Unservicable Existing Gi Tubing Of 20Mm Bore And Fittings Complete Complete All As Specified And As Directed By Engineer-In-Charge. 78 Material And Labour For Cutting Chases In Brick Wall , Pinning In. Making Good To Facings Where Required And Pointing In Cement Mortar 1:3 Or Pcc 1:2:4 To Ends Or Edges Of Landings, Steps, Cills, Sunshades, Shelves, Lintels, Etc.; And Cutting Chases For Concealed Water Tubing Or Concealed Conduit Wiring, Etc., And Making Good, Cutting Exc 10 Cm But Not Exc 20 Cm Girth Complete All As Specified And As Directed By Engineer-In- Charge.. 79 Supply And Fixing In Repair Brass Chromium Plated Wall Mixer For Mixing Hot & Cold Water Screwed Down, Screwed For 15Mm Bore Pipe Or For Brass Ferrule Complete All As Specified And As Directed By Engineer-In-Charge. 80 Supply And Fixing In Repair Bib Taps Cost Copper Alloy With Crutch Or Butterfly Handle , Screwed Down , Chromium Plated Screwed For Iron Pipe Or Brass Ferrul For 15Mm Bore Dia Pipe Complete All As Specified And Director. 81 Supply And Fixing In Reapir 15Mm Bore Bib Tap, Long Body, Fancy Type, Chromium Plated, Cast Copper Alloy With Crutch Or Butterfly Handle, Screwed Down, Screwed For Iron Pipe Or For Brass Ferrule Complete All As Specified And As Directed By Engineer-In-Charge. 82 Supply And Fixing In Repair 15Mm Bore Stop Valves, Fancy Type, Chromium Plated With Long Shank And Cup (Concealed Type) Cast Copper Alloy, Screwed Down, High Pressure, With Crutch Or Butterfly Handle, Screwed Both Ends For Iron Pipe Or For Unions And Fixed For Iron Pipe Or For Brass Ferrule Complete All As Specified & Directed By Engineer-In-Charge. 83 Supply And Fixing In Repair Angular Stop Cock With Wall Flange, Fency Type Chromium Plated Cast Copper Alloy Screwed Down, High Pressure, Screwed One Ends For 15Mm Bore Of Iron Pipe Or For Union And Fixed In Position Complete All As Specified & Directed By Engineer-In-Charge. 84 Supply And Fixing In Repair Vitreous China Wash Hand Basin, White, Flat Back, Size 450Mm X 300 Mm Including Cast Iron Cantilever Bracket With And Including 32 Mm Dia Brass Waste Coupling And With And Including Fixing Of Waste Fitting And Union Complete All As Specified And As Directed By Engineer-In-Charge. 85 Supply And Fixing In Repair Ptmt Mirror Cabinet Of Size 380Mm X 450Mm Best Quality Confirming Ot Sample Kept In GeS Office Complete All As Specified And Directed By Engineer-In-Charge. 86 Supply And Fixing In Replacement Sink With Drainage Board Made Of Stainless Steel 1 Mm Thick Kitchen Or Laboratory With Plugs, Washers And Wastes; Including Bedding In Cement Mortar To Dwarf Wall Or Including Fixing Cantilever Brackets And Connecting Union To Pipe Overall Size 915Mm X460Mm Bowl Size 410Mm X330Mm X160Mm Complete All As Specified And As Directed By Engineer-In-Charge. 87 Supply & Fixing In Replacement Brass Cp Mixer For Mixing Hot & Cold Water Screwed Down For Iron Pipe And Fixed For Iron Pipe 15Mm Bore Complete All As Specified And As Directed By Engineer-In-Charge. 88 Supply And Fixing In Repair Stainless Steel Plate Rack Of Size 900Mm X 600Mm X 250Mm And Thickness Of Stainless Steel Strip Of 1Mm Fixed On Wall Etc. Complete All As Specified And Directed . 89 Material And Labour For Cutting Holes In Brick Walls Built In Cement Mortar (Not Exceeding Half Brick) For Inserting Hold Fast And Making Good Dismantled Portion In Cm 1:3 Or Cement Concrete 1 : 2 : 4 , Type B1 As Required , Depth Of Embedded Portion Exceeding Half Brick Walls And Not Exceeding One Brick Of Hold Fast Or Lugs Measured From The Face Of The Jamb Into Walls Complete All As Specified And As Directed By Engineer-In- Charge. 90 Material And Labour For In Repair Vitreous China Wash Down Water Closet Pan Wall Hanging Single Piece (With And Including Flushing Cistern Ewc) P Trap, With And Including White Coloured Closed Pattern Plastic Seat Cover, Hand Faucet , With And Including Mild Steel Chromium Plated Or Aluminised Hinging Device Complete All As Specified And As Directed By Engineer-In- Charge. 91 S & F In Repairs Cp Stainless Steel Grating (With Or Without Waste Hole), 125Mm Size, Fixed On Floor/Nahani Gully Trap Traps Etc Complete All As Specified And Directed. 92 S&F In Repair 25Mm Dia And 1Mm Thick Stainless Steel Drapery Rod Including With Bracket / Wall And Other Side Fancy Knobs At Both Ends As Approved By Engineer-In-Charge/Ge Including Taking Down Old Existing Rod/Pelmet With Accessories Complete All As Specified. 93 Supply And Fixing Cp Brass Fancy Type Corner Glass Shelf (25Cm/30Cm ) With Cp Brass Bracket & Railing Etc. Complete All As Specified And As Directed By Engineer-In- Charge. 94 Supply And Fixing In Repair Stainless Steel, Chromium Plated, Decorative Type, Soap Dish Holder Of Approximate Size 160Mm X 160Mm X 90 Mm Fixed To Wall With Rubber Plugs Complete All As Specified And As Directed By Engineer-In-Charge. 95 Supply & Fixing In Replacement Brass Chromium Plated Tubular Towel Rail 20Mm Dia D Type, 600Mm Long Between Flanges Fixed To Plug , Bracket With Chromium Plated Brass Screws Complete All As Specified And Directed By Engineer-In-Charge. 96 Supply And Fixing 110 Mm Bore Of Pipe Pvc (Swr) Type B Pipes Single Socket 6 Kg/Sq Cm In Any Length With Stack Clamps Made Out Of 50Mm By 5 Mm Flat Iron And 16Mm Dia Round Iron Stays, Including Bolts And Nuts And Securing Ends Of Stays To Wall At A Distance Of 100-120Mm Away From Walls Complete All As Specified And As Directed By Engineer-In- Charge. Including Taking Down Old Ac Eaves Gutters And Rainwater Pipes ( Of Any Size And Pattern), Including All Fittings, Compete All As Specified And As Directed By Engineer - In-Charge. 97 Supply & Fixing 110 Mm Bore Of Pipe Pvc (Swr) Type B Ring Fit Pipes Single Socket In Any Length With Stack Clamps As Shown In Btd Drg No. 916 Sheet 1/4 To 4/4 And Btd-917 Sheet Sheet 1/1 Of Stays To Wall At A Distance Of 100-120Mm Away From Walls Complete All As Specified And As Directed By Engineer-In- Charge Including Taking Down Old Ac Eaves Gutters And Rain Water Pipes ( Of Any Size And Pattern) Including All Fittings, Compete All As Specified And As Directed By Engineer - In-Charge. 98 Dismantling And Disconnecting Of Existing Ci Soil Vent Pipe 100 Mm Bore Fixed To Wall,Laid In Trenches Incl All Fittings & Accessories Complete All As Specified And Directed. 99 Dismantling And Disconnecting Of Existing Ci Soil Vent Pipe 75 Mm Bore Fixed To Wall,Laid In Trenches Incl All Fittings & Accessories Complete All As Specified And Directed. 100 Supply And Fixing 110 Mm Bore, Pvc (Swr) Fittings Type -B Such As Bends, Tee, Shoe Etc; Fixed To Pvc Pipes, Compete All As Specified And As Directed By Engineer - In-Charge. 101 Supply & Fixing 110Mm Bore Pvc (Swr) Pipes Single Socketed In Any Length With Rubber Ring Joints Laid In Trenches Or In Floors Complete All As Specified And As Directed By Engineer-In- Charge. 102 S&F 110 Mm Bore Of Pvc (Swr) Bends And Tee, Type - B Of Any Radius / Shoe With Access Door Fixed To Pvc Pipes Complete All As Specified And Directed. 103 S&F 75 Mm Bore Of Pipe Pvc (Swr) Pipes Type - B Single Socket In Any Length With Rubber Ring Joint Fixed To Walls With Ms Clamps Of F1 25X2Mm Complete All As Specified And Directe 104 S&F 75 Mm Bore Of Pipe Pvc (Swr) Pipes Type - B Double Socket In Any Length With Rubber Ring Joint Fixed To Walls With Ms Clamps Of F1 25X2Mm Complete All As Specified And Directe 105 S&F 75 Mm Bore Of Pvc (Swr) Bends & Tee, Type - B Of Any Radius / Shoe With Access Door Fixed To Pvc Pipes Complete All As Specified And Directed. 106 S&F In Repairs Pvc (Swr) Gully Trap Of Size 150 X 150 Mm, Square Or Round Mouthed, Type P Setting And Jointing With Solvent Cement Complete All As Specified And Directed. 107 Supply And Fixing In Repair Pvc (Swr) Type -B Floor Trap Any Type (Q, S, P), 110/75Mm Dia With Grating Including Jointing To Waste Pipe Fixed In Cement Concrete (1:2:4) Type B-1 Using 20Mm Graded Stone Aggregate Complete All As Specified And Directed By Engineer-In- Charge. 108 Supply And Fixing In Replacement 10 Litres Capacity Pvc Valveless Syphonic Action Type Low Level Flushing Cistern White With Inlet, Ball Valve, Float, Handle Including Brackets And 32Mm Dia Pvc Flush Pipe Complete All As Specified And Directed By Engineer-In-Charge. 109 S&F In Repair Vitreous China Wash Basin, White, Oval Type , Size 450 Mm X 300 Mm Fixed On And Including Cast Iron Cantilever Bracket, 32 Mm Dia Brass Waste Coupling And Including Fixing Of Tap, Waste Fitting And Union Complete All As Specified And Directed. 110 Supply & Fixing In Repair Chromium Plated Square Shower Rose 200Mm X 200Mm Size, With Or Without Swivel Joints, Any Size, Including Fixing To Steel Pipe Or Union For 15Mm Bore Of Pipe Complete All As Specified And As Directed By Engineer-In-Charge. 111 Supply & Fixing In Repair Pvc Connections 15Mm Size With Brass Nuts Of Length 450Mm Complete All As Specified And As Directed By Engineer-In-Charge. 112 Supply & Fixing In Repair Pvc Waste Pipe With Socket Suitable For Connection To Waste Fittings Of 32/40Mm Dia, And Of Length Minimum 75 Cm Complete All As Specified And As Directed By Engineer-In-Charge. 113 Supply And Fixing In Replacement Three Layers 500 Litre Hdpe Water Storage Tanks Polyproof. White In Colour Rotational Moulded Polyethylene (Cylindrical Vertical With Closed Top) Hoisted And Fixed In Position Including Supply And Fixing Of Suitable Size Inlet/Outlet Arrangement & Other Accessories Complete All As Specified And As Directed By Engineer-In-Charge. 114 Supply And Fixing In Replacement Three Layers 1000 Litre Hdpe Water Storage Tanks Polyproof. White In Colour Rotational Moulded Polyethylene (Cylindrical Vertical With Closed Top) Hoisted And Fixed In Position Including Supply And Fixing Of Suitable Size Inlet/Outlet Arrangement & Other Accessories Complete All As Specified And As Directed By Engineer-In-Charge. 115 Supply And Fixing In Repair Ball Valve High Pressure Of Ptmt With Epoxy Coated Aluminium Rod And High Density Plastic Ball Screwed For Iron Pipe Of Size 20 Mm Bore (Minimum Weight 20Mm-210 Gram) Complete All As Specified And As Directed By Engineer-In- Charge. 116 Supply & Fixing In Repair Gun Metal, Globe Or Gate Valve (Isi Marked), Brass Cast Copper Alloy, With Iron Wheel Head, Screwed Both Ends Suitable For 20Mm Bore Iron Pipes Complete All As Specified And As Directed By Engineer-In-Charge. 117 Supply & Fixing In Repair Gun Metal, Globe Or Gate Valve (Isi Marked), Brass Cast Copper Alloy, With Iron Wheel Head, Screwed Both Ends Suitable For 25Mm Bore Iron Pipes Complete All As Specified And As Directed By Engineer-In-Charge. 118 Supply And Fixing In Replacement Bevelled Edge Mirror Selected Quality 5Mm Thick Glass Mounted And Fixed To With Chromium Plated Brass Screws And Cup Washers, With And Including Pvc Frame Around Made Of Pvc Channel, Complete All As Specified And Directed By Engineer-In-Charge. 119 Supply And Fixing In Repairs Sheet Glass Shelf Assembly Consisting Of 5.5Mm Thick Sheet Glass Shelf 12Cm Wide With Chromium Plated Bracket Guard And Railing 60Cm Long Complete All As Specified And As Directed By Engineer-In- Charge. 120 Roughening Surfaces Of Old Concrete Floor By Picking, Sweeping Clean And Washing Down With Water To Remove Dust, Etc. Complete All As Specified And As Directed By Engineer-In-Charge. 121 Dismantling Floor, Hearth Or Wall Tiling Including Cement Mortar Bedding (But Not Backing), Removing Serviceable Tiles To Store And Rubbish Off The Permises Etc. Complete All As Specified And Directed By Engineer-In-Charge. 122 M&L For Pcc (1:2:4) Type B-1, Using 20 Mm Graded Stone Aggregate As In Floor Surface Finished Fair 30 Mm Thick Below Tiles Complete All As Specified And Directed. . 123 M & L Non-Skid Coloured Ceramic Tiles 7 To 8 Mm Thick (Square/ Rectangular) Area Of Each Tile Exceeding 0.11 Sqm But Not Exceeding 0.18 Sqm, In Floors Etc. Set And Jointed In Neat Cement Slurry And Pointed In White Or Coloured Cement To Match Over & Including 15Mm Thick Screed In Cm 1:6 Complete All As Specified And Directed. 124 Material And Labour 25Mm Thick Cement Concrete Type B-1, 1:2:4 (12.5 Mm Graded Stone Aggregate) As Floors, Sub-Floors Etc And Finishing Surfaces Of Concrete Topping As Even & Fair Or Even & Rough To Receive The Topping Layer Complete All As Specified And Directed By Engineer-In-Charge. 125 Material And Labour For Double Charge Vitrified Ceramic Tiles ,Stain Free, Having Size Not Less Than 600X300Mm And 8 Mm Thick, Premium (1St Quality) Straight Edge, Colour As Approved By Ge , As In Vertical Surfaces Such As Skirting , Set And Jointed In Neat Cement Slurry And Laid Over And Including 10 Mm Thick Rendering In Cement Mortar 1:4 Complete All As Specified And As Directed By Engineer-In- Charge. 126 Material And Labour Granite (Of Any Type) Work (Table Rubbed And Polished) As In Steps, Pillars,Win Dow-Cills, Cooking Platforms And Like In Laid Over And Including 15 Mm Thick Screed In Cement Mortar (1:4) And Pointing In White Cement (1:2) Using Marble Dust With Admixture Of Pigment To Match With Marble Shade And Roundening To The Edge Of Stone Slabs On Edges Etc. Complete All As Specified And As Directed By Engineer-In-Charge. 127 Dismantling Stone Slabs And Tiles Of Any Description Or Thickness In Floors, Aprons Etc Laid Dry Or Bedded And Pointed In Any Mortar Complete All As Specified And As Directed By Engineer-In-Charge. 128 Demolition Of Cement Concrete Reinforced Of Any Discription And In Any Position, Including Reinforcement Cut As Required To Facilitate And Including Removing Rubbish Material From Building And Thrown In Low Lying Empty Area (As Per Direcction Of Age/Je) At Any Distance Upto 500 Metres From The Site Complete All As Specified And As Directed By Engineer-In-Charge. Note:The Weight Of Scrap Iron For Schedule Of Credit Shall Be Ascertain By Boo As Ordered By Ge.The Copy Of Boo Duly Countersinged By Ge Shall Be Enclosed With Final Bill. 129 Material And Labour For Reinforced Cement Concrete, Nominal Mix,1:2:4, Type-B1, Using 20 Mm Graded Stone Aggregate As In Slabs Supported On Walls, Beams And Columns In Floors, Roofs, Landings, Balconies, Canopies, Deck Slabs And In Shelves And The Like Including Proper Compaction By Using Mechanical Viberator Complete All As Specified And Directed. Note : Reinforcement And Form Work Shall Be Measured And Paid For Separately Under Appropriate Item Of This Schedule. 130 Supply And Fixing Pvc (Hdpe) Swr, 110 Mm Bore, Single Socketed In Any Length With Rubber Ring Joints Using Solvent As Per Manufacture Instruction, Fixed To Walls Complete All As Specified Including Fixing Of Pipe To Wall With Flat Irons Clamps Of Size 25 X 3 Mm, Bolts, Washers, Nuts, Nails Etc, After Taking Down Existing Damaged Rain Water Pipe Complete All As Specified And Directed 131 Material & Labour For In Repair 75 Mm Dia Pvc (Swr) Floor Trap Type B , Plain With Grating Including Jointing With Solvent Complete All As Specified And Directed By Engineer-In-Charge. 132 Material & Labour For 100 Mm Dia Pvc (Swr) Floor Trap Type B , Plain With Grating Including Jointing With Solvent Complete All As Specified And Directed By Engineer-In-Charge. 133 Material And Labour For Water Proofing Tratment To Roof / Terrace (Material Of Water Proof Treatment As Approved By Ge) Single Component, Acrylic Based, Flexible, Micro Fibre Reinforced Waterproofing And Heat Reflective Coating System. The Treatment Shall Be Carried Out As Per The Manufacturers Instructions And Shall Include The Followings:(A) Preparation Of Substrate And Cleaning It Off All Loose And Triable By Mechanical Means(B) Open The Cracks Lines To Form , V Grooves With Cutter/Hammer/Chisel Up To 5-10Mm And Filling With Crack Filler And Pu Sealant.(C) Application Of Primer Coat @ 0.2 To 0.3 Kg/ Sqm Followed By The First Coat @ 0.75Kg/ Sqm.(D) The Second Coat Shall Be Applied @ 0.75 Kg / Sqm And Reinforced With Fabric Re-Inforcement Between The First And Second Coat.(E) The Top Coat Of Primer Shall Be Applied After The Second Coat Dries Off @ 0.05-0.08 Kg Per Sqm.(F) The Material Shall Adhere To Following Specification. Technical Specification Of Materialtensile Strength 1.5 Mpa Astm D412Elongation At Break > 200% Astm D412Adhesion In Peel > 1.5 Mpa (On Concrete Substrate) En 1542Crack Bridging Ability Passes Upto 3.2Mm Width Astm C1305Permeability To Water Vapour Passes Is 2645Water Vapour Transimission ~ 23 G/M²/24Hr Astm E96Water Absorption 134 Material And Labour For 40Mm Average Thick Pcc Padding In 1:2:4 Type B-1 (Using 20Mm Graded Stone Aggregates) As In Roof Slab Finishing The Surface Even And Fair Using Liquid Water Proofing Compound Complete All As Specified And Directed. Liquid Water Proofing Compound Shall Be Measured And Paid Separetly As Supply Only Under Appropriate Item Of Schedule A Boq. 135 Material And Labour For Making Benching With Pcc 1:2:4 Type- B0, Using 12.5Mm Graded Stone Aggregates Using With Liquid Water Proof Compound As Per ManufacturerS Instruction Along Side Wall Adjoining To Roof In Concave Shape Complete All As Specified And Directed. Note : Liquid Water Proofing Compound Shall Be Measured And Paid Separetly As Supply Only Under Appropriate Item Of Schedule A Boq. 136 Material And Labour For Cement Concrete 1:2:4 , Type B-2 Using 40 Mm Graded Stone Aggregate As In Foundation Filling And Mass Concrete Complete All As Specified And As Directed By Engineer-In-Charge. 137 Material And Labour For Water Proofing Compound Complete All As Specified And Directed. 138 Supply And Laying Dwcpe (Sn 8) Drain Pipes 150 Mm Nominal Dia As Per Is-16098 (Part-Ii), Laid In Trenches On Bed Including All Accessories/ Fittings/ Jointed Ring, Jointing And Testing Complete All As Specified And As Directed By Engineer-In- Charge.Note:- Excavation , Earth Work, Bedding And Pedestal / Anchorage If Required Shall Be Measured And Paid Separately Under Appropriate Item Of Boq/ Sch A 139 Material And Labour For Pcc (1:3:6) Type C-2 Using 40 Mm Graded Stone Aggregates As In Concrete Bed Of Sgsw Drain Pipes Of 150 Mm Bore, Laid To Required Slope Including Packing Under And Haunching Against The Sides Of Pipes After They Are Laid And Tested Complete All As Specified And As Directed By Engineer-In-Charge. Note :- (I) Thickness Of Concrete Bed Below The Barrel Of Pipe Shall Be 10 Cm. (Ii) Width Of Concrete Bed Shall Be Outer Diameter Of Drain Pipes (Not Of Sockets / Collar) Plus 30Cm. 140 Material & Labour For Antitermite Treatment Along The External Wall Below Concrete Or Masonry Apron Using Chemical Emulsion @ 2.25 Litres Per Linear Metre Including Drilling And Plugging Holes Etc. In Apron/Plinth Etc., Complete All As Specified And As Directed By The Engineer-In-Charge. 141 Material And Labour For Att At Points Of Contact Of Wood Work By Chemical Emulsion (In Oil Or Kerosene Based Solution) @ 0.5 Litre/Hole By Drilling 6Mm Dia Holes At A Downward Angle Of 45 Degree At 150Mm Centre To Centre And Sealing The Same Complete All Sepecified And Directed By Engineer-In-Charge. 142 Material And Labour For Att Of Soil Under Existing Floors Using Emulsion @ One Liter Per Hole, 300Mm Apart Including Drilling And Plugging 12Mm Dia Holes With Cement Mortar 1:2 (1 Cement :2 Coarse Sand) To Match The Existing Floors Complete All Sepecified And Directed By Engineer-In-Charge. 143 Material And Labour For Writing Letters Or Figures (Block,Roman, Italic Ot Indian) Of Any Description, Not Exceeding 30Cm High With Paint Complete All Sepecified And Directed By Engineer-In-Charge. 144 Material And Labour For Cutting Into Existing Manholes For Connecting New Drains, Making Good To Pipe And Rendering, Cutting Out Existing Benching For And Forming Branch Channel (1/2 Round Or 3/4 Section) In Cement Concrete 1:2:4 Type B-L Smooth Finished, And Reforming Benching As Required For Internal Dia Of Pipe In 150 Mm Complete All As Specified And As Directed By Engineer-In-Charge. 145 Taking Down Cement Or Cement Lime Plaster On Brick Or Stone Walls, Etc. Including Raking Out Joints, Hacking For Key, Scrubbing Down With Water, Etc. Complete All As Specified And As Directed By Engineer-In-Charge. 146 Material And Labour For 15Mm Thick Rendering In Cm (1:6) (Internal Surface) On Other Than Fair Faces Of Brick Work Or Concrete Surfaces And Finishing Even & Smooth But Without Using Extra Cement Complete All As Specified And As Directed By Engineer-In-Charge. 147 Material And Labour For Factory Made,Machine Pressed Precast Interlocking Paver Block 60 Mm Thick With Grey Cement And No Pigment, Any Shape And Size, Conforming To Is 15658-2006, Made Out Of M-35 Grade Concrete Laid Over Sand Cushioning Complete All As Specified And As Directed By Engineer-In- Charge. Note: The R Sand Cushioning Shall Be Measured And Paid Seperately Under Appropriate Item Of Schedule A Boq. 148 Dismantling Of Brick Tiles Or Terracing Tiles Single Layer On Roof & Disposal Of Retrieved Material Upto A Distance N.Exc 100M Where Directed, Complete All As Specified And Directed By Engineer-In- Charge. 149 Demolition Of Mud In Roofs, Any Thickness, Including Plastering And Leeping (Whether Full Thickness Removed Or Only A Part Thereof Disposal Off Rubbish Upto A Distance Not Exceedomg 500.00Mtr Where Directed ) Complete All As Specified And Directed By Engineer-In- Charge. 150 Material And Labour For 15Mm Thick Screed Bed Or Bedding Layear In Cement Mortar 1:4 On Roof Surfaces, Parapet Or Vertical Beam Surface (Horizontal Or Vertical) Finishing The Surfaces Even And Fair Complete All As Specified And Directed By Engineer-In-Charge. 151 Supply And Fixing Anodised Aluminium Handle, Fabricated Type 150Mm Long Complete All As Specified & Directed By Engineer-In-Charge. 152 Supply And Fixing Aluminium Anodised Barrel Tower Bolt Of Extruded Section, 200Mm Long Complete All As Specified & Directed By Engineer-In-Charge. 153 Supply & Fixing Aluminium Anodised Sliding Door Bolts 300Mm Long, With Hasp And Staple (Bolt Type) And Fixing Clips Of Sheet, Cast Or Extruded Sections And Fixing Bolts And Sliding Bolts Of Extruded Sections Or Cast-Aluminium Alloy And Fixed Complete All As Specified & Directed By Engineer-In- Charge. 154 Supply & Fixing Factory Made Steel Window Confirming To Is 1038 With Side Hung Shutters Including Projecting Type Hinges, With Steel Handle, Steel Peg Stay, Complete, Dovetailed Welded, With And Including One Shop Coat Of Zinc Chromate Primer Without Glazing Bars Including Making Good As Per Existing Surfaces Complete All As Specified & As Directed By Engineer-In- Charge.Note: The Rate Of One Shop Coat Of Zinc Chromate Primer Is Included In This Item And Nothing Shall Be Paid Extra On This Account. 155 Supply & Fixing Factory Made Steel Window Confirming To Is 1038 With Side Hung Shutters Including Projecting Type Hinges, With Steel Handle, Steel Peg Stay, Complete, Dovetailed Welded, With And Including One Shop Coat Of Zinc Chromate Primer With Glazing Bars Including Making Good As Per Existing Surfaces Complete All As Specified & As Directed By Engineer-In- Charge.Note: The Rate Of One Shop Coat Of Zinc Chromate Primer Is Included In This Item And Nothing Shall Be Paid Extra On This Account. 156 Supply Only 3.00 Mm Thick Sheet Glass Ordinary Quality ,Fixing With Oil Putty To Wooden Or Steel Surface N.Exc 0.5 Sqm Each Complete All As Specified And Directed 157 Material & Labour For Excavating In Post Holes (Or Similar Holes) Each N Exc 0.5 Cu. M, Getting Out, Returning, Filling In And Ramming Earth Or Broken Rubble Mixed With Earth Around, In Layers Not Exceeding 25 Cm, In Soft / Loose Soil Complete All As Specified And Directed By Engineer-In- Charge. Complete All As Specified And Directed By Engr-In-Charge. 158 Supply And Fixing For Mild Steel Screw Bolts 5Mm To 10Mm Dia Of Neck (Machine Made) With Hexagonal Or Square Heads At One End And Screwed The Other, Or Screwed Both Ends, Each Screwed End To Be Fitted With Washers And One Hexagonal Or Square Nut, Length Of Bolt Exc 5Cm But N Exc 10Cm Long Complete All As Specified And Directed By Engr-In-Charge. 159 Supply And Fixing For Pre -Painted Galvalume Aluminium Zinc Coating Gi Based Corrugated Steel Sheet 0.50Mm Thickness Of Any Colour Having Atensile Strength Of 550 Mpa As In Roof Covering Fixed With L Type Or J Type Or Cranked Hook Bolts All As Specified And Directed By Engineer-In-Charge. 160 Material And Labour For Roof Trusses (Framed), Trussed, Purlins, Crane Gantries, Rails And Fastenings And Heavy Bracket Framing (Beam, Tee, Angle, Channel Or Flat Sections) Including Distance Pieces, Cleats Etc Complete All As Specified And Directed By Engr-In-Charge. 161 Material And Labour For Steel Work In Tubular Post 100Mm Dia Including Special Shaped Washer Etc. Complete Using Erw Or Induction Butt Welded Tubes Conforming To I. S.1161- 1979 Grade St.-240 Including Rolled Mild Steel Joist, Channel, Angle, Or Tee Sections, Fixed Independently, Without Connecting Plates, Etc. (Cut To Ordinary Lengths I.E. Within 20Mm Of The Length Indicated Of Gde Fe 410 -S, Complete All As Specified And Directed By Engr-In-Charge. 162 Supply And Fixing In Repairs Magic Eye For Flush/Panelled Door Shutter Etc Complete All As Specified And As Directed By Engineer-In-Charge. 163 Supply And Fixing Framed Work As In Doors Or Gates Of Angle Or Other Section With Gusset Plates, Rails, Braces, Etc., Complete, Drilled For Fixing Of Steel Sheeting Or Other Covering. Doors, Etc. To Be Prepared For Hanging Or Sliding With And Including Either Hooks And Hinges Or Steel Hanging Door Fittings (Exclusive Of Steel Sheeting Or Other Covering, Running Rails And Guides) Andhanging; Also Fastening And Fixing Complete Complete All As Specified And Directed By Engineer-In -Charge. 164 Material And Labour For Preparation Of New Steel Surfaces Of Any Description Over 10Cm Width Or Girth And Applying Two Coats Of Synthetic Enamel Paint Over With And Including One Coat Of Red Oxide Zinc Chrome Primer Complete All As Specified And As Directed By Engineer-In-Charge. 165 Material And Labour For Preparing Old Steel Surfaces Of Any Description Over 10 Cm Width Or Girth And Applying One Coat Of Synthetic Enamel Paint Complete All As Specified And As Directed By Engineer-In- Charge. 166 Dismantling Boarding, Any Description, Fixed In Any Position With Nails Complete All As Specified And As Directed By Engineer-In- Charge. 167 Supply & Fixing 18Mm Thick Hdhmr Board Uv Coating, Exterior Grade As Approved By Ge, With And Including Acrylic High Gloss Sheet Of Min 1Mm Thick Over Hdhmr Board, Anti Fungal, Moisture Resistance, Anti Borer, As Per Is 14587 For Frame And Shutter For Kitchen Cabinets / Cupboards (Such As Side Wall, Shutter, Partition Back Side Of Etc. Of Cupboard And Cabinets). Complete All As Specified And Directed By Engg-In-Charge. 168 Supply & Fixing In Repairs Of Stainless Steel Cabinet / Drawers Handle Having A Length Of 250Mm And Shape Complete All As Specified And Directed. 169 Supply & Fixing In Repairs Of Partial Overlay / Fully Overlay Hydraulic Self Closing Concealed Hinges Having Size 103Mm X 64Mm Finish Of Nickel/Silver As Approved By Ge Complete All As Specified And Directed By Engg-In-Charge. 170 M&L For 40Mm Gi Pipe Medium Grade Made To Shape As In Spout Pipe As In Sunken /Verandah/ Balconey Complete All As Specified And As Directed. 171 Supply And Laying Or Fixing Or Laid In Trenches/ Ducts/ Through Pipes/ In Floors / Under Roads/ Hard Standing /Along Poles And Testing Lt Cable Xlpe, Pvc Insulated Screened, Bedded, Galvanised Steel Strip Or Wire Armourd Cable (Heavy Duty) 1100 Volt Grade With Aluminium Conductor Having Cross Sectional Area 70 Sqmm X 3.50 Core Conforming To Is-7098 (Part-I -1988) Complete All As Specified And As Directed By Engineer-In-Charge. (Excavation And Earth Work, Sand Cushioning & Gi Pipe Shall Be Measured And Paid For Separately) 172 Taking Down Carefully Copper /Aluminium Point Wiring (Light, Fan, Socket Or Power Point ) Complete Including Fitting Such As Hylem , Sheet Switches, Ceiling Rose, Pendent Holder , Sockets, Fan Regulator , Bell Push, Electronic Bell , Sunken Box Except Concealed Conduit Etc. Complete All As Specified And Directed By Engineer-In-Charge. Notes:(I) The Weight Of Aluminium Scrap , Copper Scrap And Iron Scrap Shall Be Ascertained By Boo As Ordered By Ge And Same Duly Countersinged By Ge Shall Be Enclosed With Final Bill. (Ii) The Rate Of Cutting Chases (As Required) And Making Good Surfaces To Match With Adjoining Surface Shall Be Measured And Paid Seperately Under Serial Item No. 173.00, 174.00, 175.00, 176.00, 177.00, 178.00, 179.00, 180.00, 181.00, 182.00, 183.00, & 184.00 Of Boq. 173 Material And Labour Point Wiring For One Light / Fan Point Controlled By 6 Amps One Way Modular Switch Switch With 2.5 Sqmm Pvc Insulated, Unsheathed Multi Strand Copper Conductor Cable Fr-Lsh In And Including Concealed Pvc Conduit 20 Mm Dia Heavy Duty Isi Marked, Steel Terminal Sunken Boxes And 3 Mm Thick Phenolic Laminated Sheet Top Cover For Sunken Boxes Flush To Surface For One Light Point/Fan Point, Controlled By One Switch On The Same Board With Other Switch Or Independent Including Cutting, Chasing The Surface And Then Making Good The Same In Cm (1:3) Complete All As Specified And Directed By Engineer-In-Charge. (Note:- Switches, Sockets Etc Shall Be Measured And Paid For Separately Under Items Of Schedule). 174 Material And Labour Point Wiring For One Light / Fan Point Controlled By 6 Amps Two Way Modular Switch Switch With 2.5 Sqmm Pvc Insulated, Unsheathed Multi Strand Copper Conductor Cable Fr-Lsh In And Including Concealed Pvc Conduit 20 Mm Dia Heavy Duty Isi Marked, Steel Terminal Sunken Boxes And 3 Mm Thick Phenolic Laminated Sheet Top Cover For Sunken Boxes Flush To Surface For One Light Point/Fan Point, Controlled By One Switch On The Same Board With Other Switch Or Independent Including Cutting, Chasing The Surface And Then Making Good The Same In Cm (1:3) Complete All As Specified And Directed By Engineer-In-Charge. (Note:- Switches, Sockets Etc Shall Be Measured And Paid For Separately Under Items Of Schedule). 175 All As Per Item No 174.00 Here- In -Before But For One 3/5 Pin, Modular Socket Outlet 6 Amp, On Same Board Complete All As Specified And As Directed By Engineer-In- Charge. 176 All As Per Item No 17400 Here- In -Before But For One 3/5 Pin, Modular Socket Outlet 6 Amp, On Independent Board Complete All As Specified And As Directed By Engineer-In- Charge. 177 All As Per Item No 174.00 Here- In -Before But For One 3/5 Pin, Modular Socket Outlet 5/15 Amp, On Independent Board Complete All As Specified And As Directed By Engineer-In- Charge. 178 All As Per Serial Item No 174.00 Of Boq Here-In-Before But For Modular Bell/Buzzer Point Controlled By One Push Button On Independent Board But Not Below The Switch Board, Complete All As Specified And Directed By Engineer-In-Charge. 179 All As Per Serial Item No 174.00 Of Boq Here-In-Before But For Modular Socket Outlet 3 Pin 6 Amp On Independent Board Complete All As Specified And Directed By Engineer-In-Charge. 180 All As Per Serial Item No 174.00 Of Boq Here-In-Before But For 15/16 Amp Socket Out Let By Using 2.5 Sqmm Pvc Insulated Unsheathed Copper Conductor Cable Fr-Lsh Multi Strand On Independent Board Including Provn 2.5 Sqmm Unsheathed, Multi Stranded Copper Conductor Cable Fr-Lsh Continues As Earth Wire Connected To Earth Dolly Etc Complete In Existing Conduit Complete All As Specified And As Directed By Engineer-In-Charge. 181 Material And Labour For Point Wiring For One Light / Fan Point Controlled By One Switch With 1.5 Sqmm (Nominal Area) Pvc Insulated Unshealthed Multi Stranded Copper Conductor Cable Fr-Lsh In Existing Conduit And Provision Sunken Boxes But Inclyding 3 Mm Thick Phenolic Laminated Sheet Top Cover For Sunken Boxes Flush To Surface For One Light Point/Fan Point Controlled By One Switch And Fan Regulator Including Pvc Insulated Unshealthed 1.5 Sqmm Copper Conductor Cable Fr-Lsh Connected To Common Earth Dolly Complete All As Specified And Directed 182 All As Per Srl Item No 181.00 (Here-In-Before) But Socket 3 Pin 5 Amp 230 Volt Flush Type On Same Board 183 All As Per Srl Item No 181.00 (Here-In-Before) But For One Socket Point Outlet 3 Pin 5 Amp In Incdependent Board 184 All As Per Serial Item No 181.00 Of Boq Here-In-Before But For 15 Amp Socket Out Let By Using 1.5 Sqmm Pvc Insulated Unsheathed Copper Conductor Cable Fr-Lsh Multi Strand On Independent Board Including Provn 2.5 Sqmm Unsheathed, Multi Stranded Copper Conductor Cable Fr-Lsh Continues As Earth Wire Connected To Earth Dolly Etc Complete In Existing Conduit Complete All As Specified And As Directed By Engineer-In-Charge. 185 Supply And Fixing Switch Piano, Flush Type Single Pole, One Way 5 Amp Complete All As Specified 186 Supply And Fixing Switch Piano, Flush Type Single Pole, One Way 15 Amp Complete All As Specified 187 Supply And Fixing Socket Outlet 3 Pin, 5 Amp Flush Type All As Specified 188 Supply And Fixing 2 In 1, 3 Pin, 5 And 15 Amp Flush Type Complete All As Specified 189 Supply And Fixing Modular Switch One Way , 6Amp/10Amp ,1 Module, Single Pole, 250 Volts ,Ac Supply, Isi Marked , Complete All As Specified And Directed By Engineer-In-Charge 190 Supply And Fixing Modular Socket Outlet , 6 Amp-2/3 Pin Combined 2 Module , 230 Volts , Multipurpose, Ac Supply, Isi Marked Complete All As Specified And Directed By Engineer-In-Charge. 191 Supply And Fixing Modular Switch One Way 16 Amp, Single Pole, 1 Module 230 Volts , Ac Supply , Isi Marked Complete All As Specified And Directed By Engineer-In-Charge. 192 Supply And Fixing Modular Switch Two Way 6 Amp, Single Pole, 1 Module 230 Volts , Ac Supply , Isi Marked Complete All As Specified And Directed By Engineer-In-Charge. 193 Supply And Fixing Modular Bell Push Switch 6A 1 Module , Isi Marked Complete All As Specified And Directed By Engineer-In-Charge.Note: (I) Labour Element For Taking Down Old Unservicable Material Is Included In Serial Item No.172.00 Of Boq Here-In -Before And Nothing Shall Be Extra Paid On This Account. 194 Supply And Fixing Modular Socket Outlet 6Amp/16Amp-2/3 Pin Combined,2 Module ,230 Volts ,Multi Purpose, Ac Supply, Isi Marked Complete All As Specified And Directed By Engineer-In-Charge. 195 Supply And Fixing Fan Regulator, Modular Type, 5 Step, High Speed, Two Module Complete All As Specified And Directed By Engineer-In-Charge. 196 Supply And Fixing Ceiling Rose 3 Terminal Flush Type 6 Amp 250V ,Isi Marked ,Ac Supply, Topline Series With Polycarbonate 20Mm X 50 Mm Two To Three Terminal, Complete All As Specified And Directed By Engineer-In-Charge. 197 Supply And Fixing Electric / Electronic Bell, Ding Dong Type 230 Volt Ac Supply,Isi Marked Complete All As Specified And Directed By Engineer-In-Charge. 198 Supply And Fixing Wall Mounted Extruded Aluminium/Polycarbonate Led Batten Fixture T8(G13 Holder) 1.2 M Including One Led Retrofit Tube 20(±10) Watt. 1.2 M T8 6500 Efficacy Not Less Than 90 Lumen/Watt Extruded Aluminium/Polycarbonate, Pc Diffusor And Inbuilt Driver Complete Including Making Connection Complete All As Specified And Directed 199 Supply And Fixing Lamp Holder ,Isi Marked Of Pvc/Polycarbonate Type With Back Plate Suitable For Batten Fitting With And Including 9Watt Led Retrofit Lamp (Base B-22) Complete All As Specified And Directed By Engineer-In-Charge. 200 Supply And Fixing Lamp Holder Pvc/ Polycarbonate Type With Back Plate Suitable For Batten Fitting With Led Bulb 5 Watt Lamp Base- B-22 Complete All As Specified And As Directed By Engineer-In- Charge.Note: Labour Element For Taking Down Old Unservicable Material Is Included In Serial Item No.172.00 Of Boq Here-In -Before And Nothing Shall Be Extra Paid On This Account. 201 Supply Only Led Bulb 9 W (Suitable For B22 Base), 250V Ac, Green/Red/ Clear Day Light ( Cdl) In Colour Complete All As Specified And Directed By Engineer-In-Charge.As Per Direction Of Engineer-In-Charge Colour Of Led Luminiure Cdl/Warm White Shall Be Provided By The Contractor As Per Site Requirment And Nothing Shall Be Paid Extra On This Account.Notes:(A) Contractor Has To Furnish A Replacement Warranty Of 02 Years For Led Bulb Complete Including Lamp/ Strip From The Certifiy Date Of Completion Of Ca. The Product Will Be Replaced Free Of Cost In The Following Case :-(I) Manufacturing Defects.(Ii) Failure Due To Mechanical And Electrical Impact. (Iii) Drop In Lumen (Or Lux At 1 M) Below 90% Of Clamied Values Of Lumen(Or Lux At 1 M) Of The Led Bulb . (B) All Led Bulbs Must Meet The Provision Laid Down In Is - 16101, 16102 Part -I/Ii,16103 Part -I, 16104,16105,16106, 16108/2012 And 15885 Part -Ii / Section 13. (C) Scope Of Work Shall Include To Fix Led Bulb Walls/Ceiling Which Includes Needful T & P And Required Accessories Etc If Any, Complete Including Making Connection, Testing Etc Complete. No Extra Payment Is Admissible On These Account.(D) Old Unservicable Retrieved Material Shall Be Deposited In The Store Yard Of Age E/M Ge (North) Bathinda By The Contractor His Own Arrangements And Nothing Shall Be Paid Extra On This Account. (E) The Rate Of Electric Connection Connecting With Using Flexible Copper Wire Twin Core Upto Ceiling Rose/Connector Is Included In This Item And Nothing Shall Be Paid Extra On This Account. 202 Supply And Fixing In Replacement Led Panel Light Fitting Recessed Mounted,Square Shaped Of Size 600Mm X 600Mm , 36 (±10%) Watt, Efficacy Not Less Than 100 Lumen/Watt , Extruded Aluminium/Polycarbonate, Pc Diffusor And Inbuilt Driver Complete As Per ManufacturerS Instructions With And Including Connection With Flexible Twin Core Copper Cable Of Size 23/.00076 From Ceiling Rose To Fitting Complete All As Specified And As Directed By Engineer-In- Charge. 203 Material And Labour In Replacement Sub Main Wiring Complete With Two Single Core 6 Sqmm,1100 Volts Grade, Pvc Insulated, Multi Stranded Copper Conductor Cable Frlsh With And Including Single Core 6 Sqmm,1100 Volts Grade, Pvc Insulated, Multi Stranded Copper Conductor Cable Frlsh For Earth Wire In Existing Pvc Concealed Conduit (Colour Code Phase-Red, Neutral-Black And Earth As Green) Complete All As Specified And Directed By Engineer-In-Charge. Notes:-(A) Three Single Core 6 Sqmm Frlsh Pvc Insulated Unsheathed With Multistranded Copper Conductor Cable 1100 Volts Grade Shall Be Measured As One Length. 204 Supply And Fixing In Replacement Mcb 40Amp -63 Amp Spn ,240Volt , Rupturing Capacity 10 Ka , Curve ‘C’ Isi Marked, Complete All As Specified And Directed By Engineer-In-Charge. 205 Supply And Fixing In Replacement Mcb 6Amp -32 Amp Sp ,240Volt , Rupturing Capacity 10 Ka , Curve ‘C’ Isi Marked, Complete All As Specified And Directed By Engineer-In-Charge. 206 Supply And Fixing In Replacement Mcb 32 Amp Spn ,240Volt , Rupturing Capacity 10 Ka , Curve ‘C’ Isi Marked, Complete All As Specified And Directed By Engineer-In-Charge. 207 Supply And Fixing In Replacement Sheet Metal Enclousers Made Out Of Crca Mild Steel Sheet Not Less Than 1.2Mm Thick,, Double Door, Powder Coated Db Spn 8 Way 240 Volt, Ip -54, 200 Amps Rated Bus Bar, Dust And Vermin Proof Suitable For Incorporation Of McbS And Isolators Etc Complete All As Specified And As Directed By Engineer-In- Charge.Note: Mcb/ Isolators Shall Be Measured And Paid Seperately Under Appropriate Item Of Boq. 208 Supply And Fixing Sheet Metal Enclousers Made Out Of Crca Mild Steel Sheet Not Less Than 1.2Mm Thick,, Double Door, Powder Coated Db Spn 12 Way 240 Volt, 200 Amps Rated Copper Bus Bar, Dust And Vermin Proof Suitable For Incorporation Of McbS And Isolators Etc Complete Complete All As Specified And As Directed By Engineer-In- Charge.Note: Mcb/ Isolators Shall Be Measured And Paid Seperately Under Appropriate Item Of Boq. 209 Supply And Fixing In Replacement Sheet Metal Enclousers Made Out Of Crca Mild Steel Sheet Not Less Than 1.2Mm Thick,, Ip-54 Protection, Flush Mounted For Metal Door, Powder Coated Db Tpn 4 Way, 415 V Ac With 63 Amps Rated Bus Bar, Double Door, Dust And Vermin Proof Suitable For Incorporation Of Incoming Mccb And Outgoing Mcb Sp/Tp And Earth & Neutral Bus Bar Etc Complete All As Specified And As Directed By Engineer-In- Charge.Note: Mcb/ Isolators Shall Be Measured And Paid Seperately Under Appropriate Item Of Boq. 210 Supply And Fixing Wall Mounted Extrdued Aluminium Housing Led Betten Fixture With Tube 1.2 M, 20 Watt Inverter Type, 1.2 M 3000/6500K, Efficacy Not Less Than 90 Lumen/Watt, Extruded Aluminium/Polycarbonate, Pc Diffusor And Integrated Inbuilt Driver Complete Including Making Connection Complete All As Specified And As Directed By Engineer-In- Charge. 211 Supply And Fixing Wall Mounted Extrdued Aluminium Housing Led Betten Fixture With Tube 1.2 M, 25 Watt Inverter Type, 1.2 M 3000/6500K, Efficacy Not Less Than 90 Lumen/Watt, Extruded Aluminium/Polycarbonate, Pc Diffusor And Integrated Inbuilt Driver Complete Including Making Connection Complete All As Specified And As Directed By Engineer-In- Charge. 212 Supply And Fixing Led Batten Fitting 1X10 Watt, 6500K, 2 Ft Complete With Decorative Ultra Slim Square Profile Led Lighting Fixture With Extruded Polycarbonate Environment Friendly, Energy Efficient Complete With All Light Connection All As Specified And Directed 213 Supply And Fixing In Repair Led Street Light Fitting 35 Watt 230 V Ac Outdoor Type With High Pressure Die Cast Aluminium Hosing And Heat Resistant Complete With Driver, Lamp Bracket With Impact And Corrosion Resistant Complete With Ip 65/66 Protection Including Fixing With Gi/Ms Bracket Made Out Of Suitable Size Of Light Grade Tube Upto 1.2 Mtr Length Bent To Shape With 02 Sets Of Ms Clamps Made Out Of Minimum 3 Mm Ms Flat Iron With Iron With Suitable Bolt And Nuts Complete With Making Connection Complete All As Specified And Directed 214 Supply & Fixing Building Security Led Light Of 35 Watt , Ip 66 , Luminaire With High Power With Toughened Glass Complete As Per ManufacturerS Instructions With And Including Bracket Made Out With 40Mm Bore Galvanised Iron Light Grade Pipe 1.20 Mtr Length Bent To Shape With 02 Sets Of Ms Clamps Made Out Of Minimum 3 Mm Ms Flat Iron With Suitable Bolt ,Nuts And Washers Complete And Fixing To Wall / Column With And Including Electrical Connection With 1.5 Mtr Long Twin Core Round Copper Conductor Cable Of Suitable Size And Testing Complete All As Specified And Directed By Engineer-In-Charge. Notes:(A) The Rate Of Bracket Made Out With 40Mm Bore Galvanised Iron Light Grade Pipe 1.20 Mtr Length Bent To Shape With 02 Sets Of Ms Clamps Made Out Of Minimum 3 Mm Ms Flat Iron With Suitable Bolt And Nuts And Electrical Connection With 1.5 Mtr Long Twin Core Round Copper Conductor Cable Of Suitable Size Is Included In This Item And Nothing Shall Be Paid Extra On This Account. (B) Contractor Has To Furnish A Replacement Warranty Of 02 Years For Security Led Light Fittings Complete Including Lamps From The Certifiy Date Of Completion Of Ca. The Product Will Be Replaced Free Of Cost In The Following Case :-(I) Manufacturing Defects.(Ii) Failure Due To Mechanical And Electrical Impact. (Iii) Drop In Lumen (Or Lux At 1 M) Below 90% Of Clamied Values Of Lumen(Or Lux At 1 M) Of The Led /Luminaries. (C) All Security Led Light Must Meet The Provision Laid Down In Is - 16101, 16102 Part -I/Ii,16103 Part -I, 16104,16105,16106, 16108/2012 And 15885 Part -Ii / Section 13. (D) Scope Of Work Shall Include To Fix Security Led Light Fittings Walls/Building Which Includes Needful T & P And Required Accessories Etc If Any, Complete Including Making Connection, Testing Etc Complete. No Extra Payment Is Admissible On These Account. 215 Supply And Fixing Jointing Of Double Walled Corrugated Pipe (Dwc) As Ug Cable Protection Complete Of Size 63 Mm, Complete All As Specified And Directed By Engineer-In-Charge 216 Supply And Fixing Jointing Of Snap Fit Coupler For Double Walled Corrugated Pipe (Dwc) Of Ug Cable Protection Complete Of Size 63 Mm, Complete All As Specified And Directed By Engineer-In-Charge 217 Supply And Fixing Mccb With Adjustable Type, 4 Pole, 63 Amps, 415 Volts, 50 Hz, 25 Ka And Including Sheet Metal Enclosure Out Door Type Made Out Of 3.15 Mm Thick Crca Sheet Mounted On Angle Iron Padesta Including Grouting Complete All As Specified And Directed By Engineer-In-Charge. 218 Material And Labour For Earthing Complete With Galvanised Steel Earth Plate Electrode 600Mm X 600Mm X 6 Mm Thick Burried Directly In Ground To Depth Of Pit Not Less Than 2.25 M Below Normal Ground Level With Top Edge Of The Plate Not Less Than 1.5 M Below Normal Ground Level Surrounded From All Sides By 15 Cm Thick Packed Layer Of Charcoal / Coal Dust And Common Salt Filling In Alternate Layers And Connected To Galvanised Earth Lead Wire 4 Mm Dia By Means Of Bolts, Nuts, Check Nuts And Washers Of Gi Or Steel Including Gi Protection Pipe 15Mm Dia Light Grade Upto The Extent Of 7.5 Metre And Connecting To Earthing Test Point, Main Switch Board Including Gi Pipe 20 Mm Dia Light Grade For Watering, Ms Funnel And Bringing Out The Watering Pipe Upto 30 Cm Above The Normal Ground Level Plugged At Top Including All Fitting Including Pcc Earth Pit With Pcc 1:2:4 Type B-1 Using 20Mm Graded Stone Aggregate And Rcc Pit Cover Including Necessary Earthwork And Excavation In Any Type Of Soil Complete All As Specified As Shown In Electrical Plate No 3 Of Ssr Part-I And Testing On Completion. Note:- (I) Earth Continuity Of Gi Wire 4 Mm Including Protection Pipe Up To 7.5 Mtrs From Earth Electrode Will Be Included In Unit Rate, Complete All As Specified And Directed. (Ii) The Rate Of Earth Work In Soft/Loose Soil I.E. Excavation, Returing Filling And Removal, Form Work Is Included In This Item And Nothing Shall Be Paid Extra On This Account. (Iii) Pcc Chamber Shall Be Constructed At Least 1.5 Metre Away From The Earth Electrode And Pipe For Watering Shall Be Provided In Slanting Manner. (Iv) The Earth Testing Arrangement Should Be Done By The Contractor As Per Direction Of Engineer-In-Charge. 219 Supply And Fixing 1100 Volts Grade Heavy Duty Cable Pvc Insulated Aluminium Strandred Conductor 6Sqmm, Served With Inner Sheathing Of Pvc Tape And Overall Pvc Sheathed In Service Connections Suspended By Insulating Hangers Not More Than 1 Mtr Apart Including 4Mm Suspenstion Wire, One Twin Core Cable Flat All As Specified And Directed 220 Supply And Fixing In Replacement Exhaust Fan 300Mm Sweep (Heavy Duty) Steel Body, Bee, 5 Star Rated ,Ac Supply, Single Phase ,230 Volts, 50Hz,1200Rpm With And Including Frame Including New Mosquito Stainless Steel Wire Mesh Of Guage 0.36Mm With Suitable Wooden Frame Protection Against Birds Etc. Mounted In Suitable Opening Arrangmement In Wall And Electric Connection With And Including Three Core Pvc Insulated Pvc Sheathed Copper Conductor Flexible Cable 24/0.2Mm Drawn In Flexible Pvc Conduit And Hanging On Wall With 04 Nos. Steel Fastners 10Mm Dia 100Mm Long With And Including Serial Number Of Fan As Issued By Engineer-In-Charge And Ge Office Name With Red Colour Permaent Marker Complete All As Specified And Directed By Engineer-In-Charge. 221 Supply And Fixing Exhaust Fan 250Mm Sweep (Heavy Duty) Steel Body, Bee, 5 Star Rated ,Ac Supply, Single Phase ,230 Volts, 50Hz,1200Rpm With And Including Frame Including New Mosquito Stainless Steel Wire Mesh Of Guage 0.36Mm With Suitable Wooden Frame Protection Against Birds Etc. Mounted In Suitable Opening Arrangmement In Wall And Electric Connection With And Including Three Core Pvc Insulated Pvc Sheathed Copper Conductor Flexible Cable 24/0.2Mm Drawn In Flexible Pvc Conduit And Hanging On Wall With 04 Nos. Steel Fastners 10Mm Dia 100Mm Long With And Including Serial Number Of Fan As Issued By Engineer-In-Charge And Ge Office Name With Red Colour Permaent Marker Complete All As Specified And Directed By Engineer-In-Charge. 222 Taking Down Unserviceable Complete Ceiling Fan Along With Blades And Deposited To Age E/M Store Yard Of Ge (South Bathinda) Complete All As Specified And Directed By Engr-In- Charge. 223 Supply & Fixing Ceiling Fan Of 1200Mm Sweep Complete With Blades, Down Rods, With And Including Remote Control, Single Phase, 50 Hz, Min Air Delivery 210 Cfm With Service Value 6.00 Bee. Five Star Rated With Brushless Direct Current (Bldc) Motor Connecting Up Complete With And Including Three Core Flexible Pvc Insulated Multi Stranded Copper Conductor Cable Of Suitable Size From Ceiling Rose / Connector, Including Extra Gi / Ms Pipe Down Rod, As Per Site Requirement , With And Including Serial Number Of Fan As Issued By Engineer-In-Charge And Ge Office Name With Red Colour Permaent Marker Complete All As Specified And Directed By Engineer-In-Charge. 224 Dismantling And Taking Down Of Existing Energy Meter And Refixing The Same Complete All As Specified And Directed By Engineer-In- Charge, 225 Dismantling And Taking Down Existing Geyser And Deposit In The Safe Custody / Store Yard Of Age E/M Of Ge (S) Bathinda And Refixing The Same After Carring Out Repair Work/ Rewiring Accn )Complete All As Specified And Directed By Engineer-In- Charge,
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 4
Contract Date: Jun 30, 2026 Contract Value : 20.35 Lakh
Government Departments No of Bidders 4
Himachal Pradesh View Result →
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Himachal Pradesh View Result →
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Himachal Pradesh View Result →
Contract Date: Jun 30, 2026 Contract Value : 5.73 Lakh
Government Departments No of Bidders 1
Himachal Pradesh View Result →
Contract Date: Jun 30, 2026 Contract Value : 14.34 Lakh
Government Departments No of Bidders 3
Himachal Pradesh View Result →
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Himachal Pradesh View Result →
47.
Defence #11192596 AOC
Tender For Provn Of Central Mi Room At Nimu; 1 Lump sum price worked out by the contractor for BUILDING WORKSas listed in Schedule ‘A’ Part-I representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES B/F from Sl page No. 43 2 Lump sum price worked out by the contractor for (SITE CLEARANCE, EXCAVATION & EARTH WORK)as listed in Schedule ‘A’ Part-II representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES B/F from Sl page No. 44 3 Lump sum price worked out by the contractor for (INTERNAL ELECTRIFICATION)as listed in Schedule ‘A’ Part-III representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES B/F from Sl page No. 50 4 Lump sum price worked out by the contractor for (INTERNAL WATER SUPPLY)as listed in Schedule ‘A’ Part-IV representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES B/F from Sl page No. 52 5 Lump sum price worked out by the contractor for (ROAD, PATH & HARDSTANDING)as listed in Schedule ‘A’ Part-V representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES B/F from Sl page No. 54 6 Lump sum price worked out by the contractor for (SEWAGE DISPOSAL)as listed in Schedule ‘A’ Part-VI representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES B/F from Sl page No. 55 7 Lump sum price worked out by the contractor for (AREA DRAINAGE)as listed in Schedule ‘A’ Part-VII representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES B/F from Sl page No. 56 8 Lump sum price worked out by the contractor for (SHED FOR DG SET)as listed in Schedule ‘A’ Part-VIII representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES B/F from Sl page No. 58 9 Lump sum price worked out by the contractor for (HOT WATER SUPPLY)as listed in Schedule ‘A’ Part-IX representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES B/F from Sl page No. 59 10 Lump sum price worked out by the contractor for (EXTERNAL ELECTRIFICATION)as listed in Schedule ‘A’ Part-X representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES B/F from Sl page No. 65 11 Lump sum price worked out by the contractor for (EXTERNAL WATER SUPPLY)as listed in Schedule ‘A’ Part-XI representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES B/F from Sl page No. 66 12 SCH A PART - XII (MISC B/R & E/M ITEMS) (REFER BOQ)Note: This schedule is not pre-priced by MES and the rate indicated as Rs 0.00 under Col 5 signifies this fact only 13 INTERNAL ELECTRIFICATIONS&F Double door three phase prewired distribution board vertical DB VTPN 8 way with acrylic door made out of CRCA sheets 1.6 mm thick,phosphatised powder coated with copper Bus Bar 200 Amps, 415 V,IP 43/IK09, Earth Stud, Din Rail, Polymide terminal blocks for incoming and outgoing circuits, inbuilt loose wire box ,ground terminal blocks ,duly prewired with thimbled flame retardant copper conductors and poly layer for protection in and includingMCCB4 pole 63 Amp rating repturing capacity 16 KA.(Note:- Single Phase MCBs are to be measured and paid for seperately) 14 S&F LED building security light, pressure die cast aluminum housing, 20/25 watts capacity, 240V, IP 65 class, with suitable in-built electronic driver complete incld. fixed on a bracket made out of 1.5 mtr long Med grade GI pipe 40 mm dia bend to shape as directed fitted on wall at a height not less than 5 mtr from groundwith MS clamp, nuts and bolts and washers as required at site and incld. connecting luminarie to the nearest ceiling rose/junction box with 1.5 sqmm PVC insulated 3 core wire complete all as directed and specified by Engr-in-Charge.NOTE - Cost of all minor spares and jobs required for fixing of light fixture on wall and for electrical connections are deemed to be included in the quoted rate. 15 S&F new wall mounted fan of approved make and type complete all as specified and as directed. 16 S&F TV Co-axial socket 1 module, complete all as specified and as directed. 17 S&F Single pole and neutral enclosure with a two pin and earth plug and socket complete with one double pole MCB 20 Amps 18 INTERNAL WATER SUPPLYS&F single piece Vitreous china wash down water closet pan Pedestal Pattern white, with seat white closed pattern with flat bottom and cover mild steel chromium plated or aluminized hinging deviced including flushing system , pipe and joint etc and connection to drain, flushing, pipe, anti-syphonage pipe, and fixing arrangements with fixing bolts etc including making good the disturbed portion of floor in cement concrete 1:2:4 type B-0, as in repairs complete all as spd & directed complete all as specified and directed by Engr-in charge.. 19 S&F CP Grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) dia of outlet is 100 mm complete all as specified and directed by Engr-in charge. 20 S&F hand shower (health faucet ) with 8mm dia and 1 meter long CP flexible tube and wall hookcomplete all as specified Make: Cera, Jaquar , Marc & Hindware as per Sample and directed by Engr -in Charge 21 S&F Soap dish (S/S), any type, fixed to plugs with chromium plated brass screws, all as specified and directed by Engr-in charge. 22 ROAD, PATH & HARD STANDINGM&L for wet mix macadam (WMM) for 150mm thick (compacted thickness) laid in two layers of 75mm each grading as per table 400-13 of MoRTH (Ministry of Road Transport & Highways) specification of Road and Bridge works 2013. Manufactured in WMM plant, material comprising of clean, crushed, graded aggregate and granular material premixed with water to a dense mass, spreading with sensor paver and rolling with vibratory roller of capacity 80-100 KN static weight and conslidating required gradient and camber. The finished surface tolerance to be as per table 900-1 of MoRTH specification for road and bridge works 2013 complete all as specified and directed by Engr-in-Charge. 23 M&L for applying thermoplastic paint marking 2.5mm thick centerline ,stop line,dashes,arrows etc and n exc 10cm wide on roads pavements with hot applied thermoplastic road marking paint ofapproved colour confirming to BS 3262-1989 with special applicater machine all as per manufacturers instructionof any colour on road surfaceincluding cleaning with gunny bags removing all loose dirt/dust complete all as specified and directed. 24 M&L for RCC Septic tank designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, RCC M-30 Design Mix in Walls , Base Slab , Baffle walls and Roof Slab including beams etc with Vent shaft , manhole openings with cover connection etc, complete with effective depth of 1.5 meter and overall depth of 3 meter for 100 users. 25 M&L for Soakage wells excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size 3M Dia and 3 M Depth. 26 EXTERNAL ELECTRIC SUPPLYS&F Polycarbonate junction boxes IP 65 protection of size 0.200 x 0.250 x 0.155 m complete with 1 Nos MCB SP 2.5 Amp & 4 way industrial connector including clamp made out of MS flat 30x5mm connection from junction box to street light fitting with three single core PVC insulated, PVC sheathed wire 2.5 Sqmm copper & PVC conduit 20 mm dia complete all as specified and directed by Engr-in-charge. 27 Excavation in trenches by cutting of road crossing/PCC hard standing, under boundary wallfor laying of pipe/cable including making good the existing surface with same finish to match the original finish complete all as specified and directed by Engr-in-charge. 28 S&FHT/LT MS cable route indicator 4 dia fixed with two Nos of nut, bolt and washers and provision of PCC 1 : 4 : 8 type D-2 using 40 mm grade stone aggregate of not less than 0.018 cum in each at base buried under the groundincl necessary earth work complete all as specified and directed by Engr-in-charge. 29 Supply, installation, testing and commissinoning LT panel board suitable for working on 3 phase ,4 wire ,415 volts, AC ,50Hz indoortype, cubicle, floor mounted, free standing, dust and vermin proof, air ventilation factory fabricated made out of 2 mm thick CRCA sheetduly powder coated and shall be CPRI Approved and as approved by GE. The Panel shall have front and rear opening, locking arrangement, cable alleys, bus bar chamber and switch gear compartment, hinged door with rubber gasket, bottom cable entry holes for incoming and out going cables, earthing terminals, affix danger notice plate, glands, AI bus bar duly covered with heat shrink sleeves colour coaded duly fixed onDMC/SMC insulators, housed in a separate bus bar chamber and control wiring with copper conductor cables of adequate size and length, incoming and outgoing MCCBs shall have extended bus bar links and mounted on 50x50x5mm sizeMS angle iron frame duly painted including PCC 1:2:4 Type B1 (using 20 mm graded stone aggregate ) in foundation design subject to approved of AGE (I) Nimu to sent the site requirementcomplete all as specified and directed including comprising of following :- 30 (a) MCCB 400 Amps, FP, 36 KA, 415 volts, 50Hz - 01 No (I/C)(b) MCCB 200 Amps, FP, 25 KA, 415 volts, 50Hz - 02 No ( CHS)(c) MCCB 125 Amps, FP, 16 KA, 415 volts, 50Hz - 04 Nos (APFC, TPN DB -02, Spare )(d) MCB SPN 40 Amps, 10 KA, 220 volts, 50Hz - 03 Nos (Garage,Street light, Spare-1)(e) On load Chengeover 400 Amps 4 pole -01 No (f)Digital voltmeter, with VSS - 01set(g) Digital Ammeter, with CTs & ASS - 01 set(h) LED phase indication lamps RYB - 01 set(j)Single phase Rotary Automatic Light controller Nature switch with voltage range 120-440V,AC,20 Amps,IP-65,50HZ-01 Nos(k) Copper bus bar TPN 600 Amps rating - 01 set 31 Labour for boring underground upto 100 mm bore for road crossing 3 mtr to 10 mtr not exceeding 1.5 mtr in depth for laying of electric cable and GI tubing in soft/loose soil complete all as specified. 32 EXTERNAL WATER SUPPLYM&Lfor cutting existing GI pipes and insertion of new Tee branches of suitable size to take branch connection of 50mm dia PP-R.Note : Suitable size of Tee branch is deemed to be included in the quoted rate. 33 Construction of stone masonary valve pit chamber of size 90cm x 90 cm x 90 cm (internal dimension) including all necessary excavation and earthwork in hard / dense soil and disposal of surplus soil to a distance not exceeding 50 meters & deposting the same as directed includingPCC in foundation of the mixture (1:4:8) D-2 stone masonary in cement motor 1:4 rendering 15mm thick in cement mortar 1:4 internally finished even and fair and pointing flush externally as the work proceeds in the same mortar as of stone masonary including mild steelframe (made out ofangle in 40x40x6mm) MS steel cover 3.15 mm thick with handle and locking arrangement with ginges angle iron flat as requiredat site including painting of all posed MS work with two coat of synthetic enamel paint over a coat of red oxide primer and painting all the steel surfaces embedded in PCC with two coats of black bituminuos paint andall other relevant work complete . 34 M&L for providing tracer/anti freezing cable of capacity 20W/m required to keep the pipe warm upto avoiding freezing all as specified including electrical wiring cable for connection of suitable size 35 (CENTRAL HEATING SYSTEM)Electric Hot Water Generator : Supply, installation, testing and commissioning ofpackage type electric Hot Water generator constructed out of MS sheet having top open-able cover for easy access and removal of heaters. The HWG shall be suitable for indoor mounting. The generator shall be provided with 50mm thick fibre glass insulation 32 kg density finished with 0.8mm / 22G aluminium cladding sheet. The generator shall have electrical capacity of 50 kW. The heater shall be electrical resistance type, copper tube with chromium plating. The generator shall be complete with float valve, pressure gauge with ball valve, master and bank thermostats, etc. The generator shall be suitable for 3 phase, 415+ 10% Volts, 50 Hz. AC supply. The generator shall complete with self-contained incoming isolation, ammeter, voltmeter, contactors for heater banks in three steps complete with manual/auto rotary switches. 36 Notes:- (i) Allneccassary accessories required for the proper fucntioning of Hot Water Genearator are included in price.(ii) The prices should include lifting, shifting and positioning of units at Site.(iii) Hot Water Genearator installation to done as per Manufacturer recommendation with all installation requirements i.e Foundation, Vibration Isolator,Insulationetc as recommended by Manufacturer for the Ambient Temperature of Site. ODU installation is included in ODU price which includes the Civil Struture, Mechanical Structureetc as recommended byManufacturer.(iv) The Contractor/OEM will shall submit the Hot Water Generator capacity/Burner Capacity conforming to relevant IS Code(v) OEM should submit the Installation and Maintenance Schedule/ Manual for the Boiler. 37 GLYCOL CIRCULATION CENTRIFUGAL PUMPS: Supply, Installation, Testing & Commissioning of PN16 ratedAxial Split Coupled Vertical Inline water pump set with CI casing, Bronze Impeller, SS Shaft and externally flushed outside type balanced mechanical seal and non overloading motor, as per specifications and drawings. with Suitable HP, TEFC squirrel cage induction motor with IE3 type class F insulation, Motor shall be rating of IP 55, operating on 415 ±10% volts, 3 phase, 50Hz AC Supply. The external flush line must be used for the purpose of heat dissipation from the mechanical seal.Pumps with performance characteristics as given below:The internal components of pumps including mechanical seal shall be suitable to sustain a fluid temperature of -25 Degree Celcius to 120 Degree Celcius. Vendor shall be provide antivibration arrangement for pumps . 38 The scope also shall include following below mentioned:(i) Electrical by pass starter for pump setas recommended by OEM. (ii) 25 mm thick polyviny nitrile rubber insulation duly cladded between aluminium sheets of 0.5mm thickness and properly clamped to pump.(iii) Pressure gauges 150 mm dia -03 Nos (iv) Mounting frame with antivibration pads (In case pumps are inline, anti vibration system shall be as per Manufacturers recommendation) (v) RCC/Cement concrete foundation for the pump unit. (In case pumps are inline, foundation shall be as per Manufacturers recommendation).Pump capacity are as under:Capacityand pump headnot less than flow 25 USGPM , Head 20 mtr (Refernce Model No. : Armstrong : Series 4300 - 40-150 - 2p - 1.5 kW) each including the Triple duty valve and End Suction guide. 39 EXPANSION TANK and Pressurisation Unit:Supply, Installation, Testing and commissioning of INSULATED PRESSURISED CLOSED WATER EXPANSION TANK suitable for total volume ofGlycol - Water Solution, circuit along with necessary accessories such as along with necessary accessories such as 2 Nos pumps (1working +1standby) with Pressure Transmitter andinterconnecting Pipe & Isolating Valve complete with piping connections, safety relief valve, drain valve, pressure gauge, automatic air purging arrangement, etc.with Pressure Transmitter andinterconnecting Pipe & Isolating Valve complete with piping connections, safety relief valve, drain valve, pressure gauge, automatic air purging arrangement, etc. The tank shall be pre-charged. Expansion tank Shall be with replaceable heavy duty butyl rubber bladder. The tankconnections should be as per OEM recommendationsand 20 mm drain and charging valve connection to facilitate the on site charging of nitrogen in the tank.The tank shall be fitted with lifting rings and a floor mounting skirt for vertical installation. The tank must be constructed in accordance with IS-STANDARD 2825-1969 (withlates Revision)and Rated at PN 16 . The complete system shall be sourced from single manufacturer and supplied and installed with all accessories and safety fixtures required for proper functioning of the complete hydronic system.The tank shall be duly painted in approved colour shall be complete with pressure switches and power distribution and control panelIP55 Control Panel, Pressure Transmitter, interconnecting piping & wiring. (Tank capacity 500 Ltrs). Hot Glycol - Water closed vessel pressurized expansion tank as described above shall be duly Insulated with 50 mm thick PUF/Nitrile Rubber insulating material or Equivalent U valueInsulating Material and cladded with aluminium Sheet (20G). Electrical by pass starter for pump setas recommended by OEM. 40 Expansion Tank of 500 Lts capacity 41 PRESSURIZATION UNIT: for Pump Set -03 Nos with Control Panel and accessories. 42 Make Up TANK: Supply, installation, testing and commissioning of factory made Make up Water Tank, Rectangular/Circular shape, of 4 mm thick MS sheet (IS 2062), of capacity of 550 litres complete with inlet, outlet, overflow, drain pipe of MS and vent with flame arrestor. Tank will be provided with supports made out of minimum 50mm angle iron duly painted, to keep tank base at minimum (1000mm) above FFL. Service platform shall be provided as per recommendations of OEM. The tank shall be provided with remote indication of levels provided level switches for on-off operation of tranfer pump. Extra high level and extra low level alarm shall be provided. Tank and structure shall be painted with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.Make up Water tank as describedabove should beduly Insulated with 50 mm thick PUF/Nitrile Rubber insulating material and cladded with aluminium Sheet (20G). 43 Supply, Installation, Testing and Commissioning ofSteel plate Radiator( Wall Mounted) confirming EN- 442 , working pressurerange from 10-13 bar having workinh temparture of 110°C, complete with top grill side cover as standard along with inlet ,outlet valve, Air purge valve andwith threaded plug, flow regulator as per OEM.The below desired capacity should be calculated at Altitude of 3600 mts above sea level. Capacity calculation sheet to be provided to Engineer in Charge. The below mentioned capacity is at INLET TEMP: 75 Degree Celcius , OUTLET TEMP: 65 Degree Celcius. Referemcwe Model Series. 44 1.5 kW, Type: 33- DKEK, Length is 1000 mm and Height is 600 mm of Radiator. 45 2.5 kW, Type: 33- DKEK, Length is 1000 mm and Height is 600 mm of Radiator. 46 3.5 kW,Type: 33- DKEK, Length is 1600 mm and Height is 600 mm of Radiator. 47 5 kW,Type: 33- DKEK, Length is 1600 mm and Height is 900 mm of Radiator. 48 5 kW,Type: 33- DKEK, Length is 2000 mm and Height is 600 mm of Radiator 49 M & L for Pre-insulated MS pipe,Class C havingminimum thicknes of PUF insulation as mentioned below and of density 36 Kg/Cum and 26 gauge AL cladding complete suitable for above ground as per sizes shown.The pipes should be insulated with closed cell puf of density 36±2 Kg/Cum of below mentioned thickness. The Pipe should be workable in the temp. range of-50 Degree Celciusto120 Degreec Celcius. Note:-The Pipes size 150mm & below shall be M.S. ‘C’ class as per IS : 1239 50 80 mm with 36 mm PUF thicknes and 26 Gauge Al Cladding. 51 65 mm with 36 mm PUF thicknes and 26 Gauge Al Cladding. 52 50 mm with 36 mm PUF thicknes and 26 Gauge Al Cladding. 53 40 mm with 36 mm PUF thicknes and 26 Gauge Al Cladding. 54 20 mm with 36 mm PUF thicknes and 26 Gauge Al Cladding. 55 Buried under ground/Exposed to Ambient:80 mm with 50 mm PUF thicknes and HDPE Cladding, 26 Gauge Al Cladding. 56 Cabel Tray :-Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling/Ground/wall with M.S. suspenders as per IS code including bolts & nuts, painting suspenders etc. as required of size 150 mm width X 50 mm depth X 1.6 mm thickness 57 Supplying, fixing, testing and commissioning of following diameter valves (PN-16 Rating) (Complete with Flanges integral or welded, fittings, Nuts, Bolts & Gaskets (PN-16 Rating), strainers (Complete with flanges integral or welded, fittings, Nuts, Bolts & Gaskets (PN-16 Rating), gauges etc for condenser water circulation as per specifications. Insulation thickness ofvalves should be equal to the Insulation of PUF and GI Cladding of Pipe Section as specified. Butterfly Valve ( Insulated Valves) with CI body SS disc nitrile sheet & O ring, Complete with fittings, Nuts, Bolts & Gaskets.Butterfly Valve ( Insulated Valves) with CI body SS disc nitrile sheet & O ring, Complete with fittings, Nuts, Bolts & Gaskets. 58 80 mm dia Butterfly Valve 59 65 mm dia Butterfly Valve 60 50 mm dia Butterfly Valve 61 Supplying, fixing, testing and commissioning of Y-STRAINER (Insulated Valves) of Ductile CI Body flanged ends with stainless steel strainer forhot water circulation including Insulation thickness ofvalves should be equal to the Insulation of PUF and GI Cladding of Pipe Section as specified of size 50 mm dia Y strainer. 62 Supplying, fixing, testing and commissioning of NON - RETURN VALVE (Insulated Valves) with duel plate of CI body SS plates vulcanized NBR seal flanged end & PN 16 pressure rating forhot water circulation includingInsulation thickness ofvalves should be equal to the Insulation of PUF and GI Cladding of Pipe Section as sepcified of size 50 mm dia NRV. 63 Supplying, fixing, testing and commissioning of Automatic Air Purge Valves forhot water circulation headeras specified of size Automtic Air Purge Valve 20 mm dia. 64 Supplying, fixing, testing and commissioning of Air Separator compleate allas specified of size 50 mm dia. 65 Supplying, fixing, testing and commissioning of water pressure gauge (100 mm dia) bourdon type with brass ball valve of 3/8 dia and SS tubing, socket.Range (0-50) / (0-100) as required by Engineer In Charge. 66 Supplying, fixing, testing and commissioning of Mercury in glass industrial thermometer in SS-304 casing with 0.5 C least count, range 0-50 C. Brass oil filled thermowell of 1/2 size as required by Engineer In Charge. 67 Electrical distribution Panel Supply, installation, commissioning and testing of factory made, CHS Plant, indoor type made out of CRCA sheet 2 mm thick, frame factory fabricated with front and back openable double door with locking arrangement, with MS angle section 50x50x6 mm support, duly powder coated painting having thickness not less than 100 microns provided suitable gasket to make it dust and vermin proof, suitable for 3 Phase4 wire, 415 Volts, 50 Hz, AC supply system, floor mounted and grounting the legs of panel in PCC foundation 1:4:8 complete as all directed suitable for and including the following :- 68 INCOMERS(i) Bus Bar TPN Al extensible type main bus bars of minimum of 600 A capacity (As per capacity of corresponding incoming / Bus couplers) , and auxilliary bus bars ofsuitable capacity with heat shrunk coloured sleeves and i/c SMC bus bars supports at required intervals complete for cross section, size supports & their spacing etc. for withstanding fault level of50kA .(ii)MCCB 400 Amps, 415 Volt, 36 KA, 4 Pole,Microprocessor release- 01 No for incoming (Extended Rotary Operating Handle, Phase Spreader links and Phase barriers ) Make: Legrand/Schenider/SimensOUTGOINGS(i) 3Nos- 125A ,25 KA TPNMCCB/ACBwith Microprocessor release (3# Hot Water Generator)(ii) MCB 10 Amp,TPN,10KA, C curve - 06, 3 Nos for Pumps , 2 Nos for Pumps ,01 Nos for glycol transfer pump(iii) LED Phase indication lamps (01 Set) with 2Amp back up MCB,Breaker ON/OFF indicating light with 2A MCB, test terminal block set, circuits as per standard practice, auxiliary contacts for positive interlocking of the breakers as required. - 2 Set (iv) Digital Ammeter with in built ASS,metering C.T.sCAST RESIN type, 15VA, and accuracy class-1of 800/5A for measuring current in each phase - 01 Set.(v) All accessories prewired with appropriate size copper strip or wire and thimbles etc. all as required including foundations as per Manufacturers recommendations all as directed by Engnr-in-Charge.Note : Contractor will submit the drawing for approval of panel to GE before execution. 69 LT CABLES : Supply & Laying/ fixing of following size XLPE insulated and PVC sheathed AI conductor armoured cable/unarmoured as required of 1.1 KV grade complete as require (ISI Marked) (in ground/in pipe/in duct/on surface/on cable tray)Note for 49.01 to 49.04 :- Cable shal withstand temperature variation (-) 35 °C to (+) 35 °C at appx 3500 mtr above sea level. 70 3.5 Core x 70 sq.mm. (Electric Hot Water Generator) 71 4.0 Core x 10 sq.mm. (Pump) and (Pressurization Unit) 72 2 Core x 10 sq.mm. (Pump) 73 2 Core x 6 sq.mm (Pressurization Unit) 74 Earthing complete with Copperearth plate electrode of size 60cm X 60cm X 6mm buried directly in ground vertically at a depth not less than 2.25 metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level surrounded from all sides by 15 cm thick and packed layer of charcoal dust and common salt filling in alternate layers etc and connected to and including Copper strip of size 32x6 mm up to 7.5 mtr by means of bolts, nuts, check nuts and washers made of brass and protected by light grade 40mm dia upto 7.5 mtr long GI pipe connected to main controlboard and GI pipe light grade 20mm bore for watering and including funnel, wire mesh, RCC pit cover 50mm thick and PCC chamber pit with PCC 1:2:4 type C2 (including excavation and earth work disposal of surplus soil to a distance not exceeding 50 metre) and testing making test point and testing after completion all as specified and shown on plate No 3 of SSR Part-I 2009 complete all as specified & directed by Engr-in-charge 75 S&F rubber matting conforming to IS-15652-2006 complete as required. of size2m x 1m x 25 mm 76 Glycol - Water SolutionSupplying of Ethylene glycol concentrate along with the necessary additives and inhibitor in cognition in sealed barrels complete all as directed.NOTE;- (i) The glycol concentrate shall be mixed with potable water supplied by contractor and filled in central heating system pipe line after proper leak test of entire circuit. The glycol water mixture ratio shall be 45 : 55 and freezing temperature shall be - 45 Degree Celcius (ii) First charge of glycol is included in the quoted rate. First Charge Include Charge in CHS pipe lineStorage Tank. (Glycol 45 % ,Water 55 %) 77 For CHS 78 Supply of Gycol for running of Plant for 12 months 79 GLYCOL CIRCULATING PUMP: Supply, Erection, Testing and Commissioning ofTransfer pumps for the capacity of 5 LPM 5 meter head for Glycol Fluidtransfer with base frame foundation, bolts coupling coupling guard,TEFC, (OEM design HP for the required Flowand Head ) andother accessories for proper function of the pump. 80 OXYGEN GAS MANIFOLD : Supply , installation , testing and commission 4+4 oxygen manifold with middle frame, tail pipe, NRV and ESSAB make 10x14 regulator complete all as specified and directed by Engr in charge . 81 Supply, installation , testing and commission 3 cylinder emergency inlet for oxygen complete all as specified and directed by Engr in charge . 82 Supply , installation , testing and commission automatic control panel with Analog Display 02 for oxygen complete all as specified and directed by Engr in charge. 83 S&F of copper tubing of size 15 mm OD, EN -13348 Grade , 0.9 mm wall thickness including proper saddling , clamping and insertion of branches connections including all fitting for medical use, complete all as specified and directed by Engr in charge. 84 S&F of copper tubing of size 12 mm OD, EN -13348 Grade , 0.9 mm wall thickness including proper saddling , clamping and insertion of branches connections including all fitting for medical use, complete all as specified and directed by Engr in charge. 85 S&F BS type gas outle with probe for oxygen for medical compleate all as specified and directed by Engr in charge 86 S&F 1/2 Brass ball valve with end fittings including all fittings for medical usecomplete all as specified and directed by Engr in charge. 87 S&F BPC flow meter (0-15 LPM) including humidfire bottle complete all as specified and directed by Engr in charge . 88 S&F 3/8 Brass ball valveincluding all fittings for complete all as specified and directed by Engr in charge. 89 STAND BY DG SET : Supply,install, test and commissioning of silent Diesel Engine Generating set 415 volts, 3 phase, 4 wireengine as per IS08528 conforming to CPCB Norms IV, and alternator as per IS08528 of capacity 400 KVA at NTP with control panel having meters, sound proof canopy etc with foundation (As per OEM design) including all accessories as per manufactures standard and as per the details given below and independent relay panel for automatic on mains failure:- AC Generator should be suitable for ambient conditions at nimu Leh area. 90 (A) Alternator : Standard design alternator rated at 400 KVA (320KW)net output at power factor 0.8, AC, 3 phase 4 wire, 415 V, 50 Cycles/Second, 1500 RPM self excited, self regulated, screen protected, drip proof IP 23 enclosure, brush less design, voltage regulation ± 2.5 % rated voltage from no load to full load and frequency regulation within ± 1.5 % tolerence. (B)DIESEL ENGINE : Vertical diesel engine of suitable capacity, closed circuit as per BS-649 or IS-1002 direct injection type, Electric starting system having rated speed 1500 RPM. The DG set Shall be capable for running with 10% over loading for 01 hour in every 12 hours as perBS-5514/BS-649. Engine shall be multi cylinder, multi stroke, direct injection andequipped with all standard fitting as per manufactures recommendations and mounted on common base frame with following Specifications.(a) Fly wheel with housing (i) Common base frame of sturdy design suitable for anti vibration mounting and permanent concrete foundation for mounting engine and alternator as per manufacturers instructions (b) Cooling system (i) Radiator with fan & belts & guard, rubber hoses and thermostat. (ii) Cooling water pump centrifugal type . 91 (c) GOVERNER : Electronic Governer (d) ELECTRIC STARTING SYSTEM : Electric Self starter , 24 volts DC(12 volt, 150 AH battery 2 Nos)charging alternatoraspermanufacturers design,copper leads with lugs of adequate size complete with initial charging of maintenance free battery 2X12 volt 150 AH capacity. (e) GENERATOR MONITORING PANEL : Comprising of following :- (i) Microprocessor based genset controller for metering, monitoring, governing and protection. (ii) Engine protection for low lub oil pressure, high coolant temperature (alarm & shutdown) (iii) Alternator protection parameters like under voltage, over current, under frequency, over frequency (alarm & shut down) (f) ACCESSORIES:AVM Pads built or separately mounted to manufacturer base frames. (g) COUPLING ARRANGEMENTS: Fixed coupling, flywheel to suit fixed coupling and fly wheel housing.(h) EXHAUST SYSTEM : should have equipped with emission control device as per latest Govt norms. Silencer complete with exhaust pipe of suitable size upto and out side the building all covered with asbestos rope of suitable size all as specified and as directed.(j) FUEL TANK: Daily service fuel tank of capacity suitable for 8 hours continuous operation made out of 3 mm thick (heat retardant) sheet with indicating gauge, built inside the acoustic enclosures or as per manufacturers design 92 (C)ACOUSTIC ENCLOSURE : All as per CPCB norms IV and OEM of DG Sets design.(D)AMF Panel : Supply, install, testing and commissioning of AMF Panel outdoor type, cubical body,dust and vermin proofmade up of CRCA sheet painted with two coats of synthetic enamelled paint over a coat of red oxide primer confirming to IP 45 with front and rear opening with louvers andmounted on floor with PCC pedestal pillars with a clearance of atleast 0.3 m above ground level with glands sockets etc with provision of cable entry from bottom all pre wired and connected complete with following accessories:-(i) Microprocessor based Panel -01 No(ii) Power Contactor heavy duty suitable for generator and mains (iii) Over load relay for genset (iv) Suitable rating isolating switch MCCB for both DG & main supply.(v) Multi functioning meter to indicate voltage, current, frequency, P F, KW & KWH etc (vi) Emergency stop push button.(vii)Set of indicaters : - (a)Low lube oil pressure (b) DG Set over load(viii) Push button to start, stop (ix) Mode selector switch i.e Auto/Manual/Test/ OFF.(x) Set of Instrument fuse (xi)Set of aluminium bus bar of 600 Amps capacity 3 ph, 4 Wire system (xii) Automatic battery charging unit with DC voltmeter, Ammeter and selector switch for trickle/ Boost charging.(xiii) By Pass arrangement of main supply when AMF circuit fail due to any fault with provision of suitable rating change overs and switches. 93 The following items are deemed to be included in the rate quoted for all DG sets:- (i) DHPP for testing purpose shall be supplied by the contractor without any extra cost to Department. (ii)The contractor shall arrange for artificial load (water load/Electrical load) for testing for final testing of DG Set at site and the cost is deemed to be including in above offer. (iii) Testing of sound level should carried out at the site in presence of Engineer-in-Charge(iv) One set of latest Spare part catalogue with price, exploded view of parts and users manual are deemed to be included in the quoted rate.(v) All civil works including foundation for DGSet as per manufacturers drawing/ specification, foundation for AMF panel shall deemed to be included in the quoted rate.(vi) The rate quoted is deemed to be included for initial filling of radiator coolant and lubricating oil upto level.
Contract Date: May 29, 2026 Contract Value : 5.74 Crore
Statutory Bodies & Commissions/Committees No of Bidders 3
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 3
Uttar Pradesh View Result →
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 3
TenderDetail
Loading tenders