View Bid Results For Access Platform Tenders

We found 1730 Bid Results related to access platform tenders. You can find Contractor details who won access platform tenders along with contract details in Bid awards announcements section.

Filters
Stage
1190
352
188
Tender Publishing Platform
150
1580
State / UT
34
310
307
125
108
89
79
77
76
69
58
49
44
39
33
30
29
27
22
21
19
14
14
13
13
11
11
10
10
8
5
5
2
2
1
Contract Value
577
321
624
204
Publish Date
7
0
0
0
0
Sector
30
414
384
341
127
76
60
43
28
27
25
23
22
20
19
18
16
14
14
12
12
9
7
3
3
3
2
2
2
2
2
Ownership
6
840
412
286
187
4
1
Within keyword
Active filters:
Showing 1–35 of 1730 tenders matching your filters
1.
Public Administrative Department #11481749 AOC
Tender For Annual Plan-Moodadi G P 2025-26 Project No.352 -N H Puliyottukunnu Drainage Ward 16-General Civil Work - DRINAGE 2 2.8.1:Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil 3 4.1.8:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) 4 4.3.2:Centering and shuttering including strutting, propping etc. and removal of form work for:Retaining walls, return walls, (any thickness) including attached pilasters, buttresses, plinth and string courses fillets, kerbs and steps etc. 5 4.1.5:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) 6 4.1.3:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III)derived from natural sources : 4 graded stone aggregate 20 mm nominal sizederived from natural sources) 7 5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more 8 5.9.3:Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform 9 5.1.2:Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size derived from natural sources) 10 10.25.2:Item Shifted to Sub head 14 as item 14.73Item Shifted to head 14 as item 14.74Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
Contract Date: Jul 03, 2026 Contract Value : 1.68 Lakh
Government Departments No of Bidders 1
2.
Defence #11478095 Technical Bid
Tender For Provision Of Certain Revenue And Minor Work At Age B/R Ii Under Ge(N) Patiala=- 1 Dismantling, Floor, Hearth Or Wall Tiling Including Cm (Bedding (But Not Backing), Removing Serviceable Tiles To Store & Rubbish Off The Premises Complete All As Specified And Directed 2 M&L For Single Charge, Vitrified, Stain & Scratch Resistant, Premium Quality Coloured Tiles Area Of Each Tiles Exceeding 0.42 Sqm But Not Exceeding 1.00 Sqm, In Floors Etc Mm And 8-10 Mm Thick, In Any Pattern Of Light & Dark Tiles As Approved, Laid Over 15 Mm Thick Screed In Cm (1:6) Epoxy Cartridge Tile Grout Using Filling The Joint Of Tiles Complete All As Specified.Note- Epoxy Black,Golden Colour,Complete All As Specified And Directed. 3 All As Per Item No 2 Above But As In Skirting Over 10 Mm Thick Rendering In Cm 1:4 Complete All As Specified And Directed. 4 M&L For Ceramic Glossy Finish, Joint Free Premium Quality Coloured Tiles 600 X 300 Mm And 8-9 Mm Thick, In Any Pattern Of Light & Dark/Highlighters Tiles Etc As Approved, On Vertical Surfaces Such As In Skirting/Dado Etc, Set And Including 10 Mm Thick Rendering In Cement Mortar (1:4) And Pointed In White Cement With Pigment To Match The Colour Of Tiles Complete All As Specified. 5 M & L For 15 Mm Thick Artificial Granite (Of Any Type) Work Steps, Jambs, Pillars, Window- Cills, Cooking Platforms And Like In Cement Mortar (1:4) Including Pointing In White Cement (1:2) Using Marble Dust With Admixture Of Pigment To Match With Shade Of Granite. Including Screed Bed Or Bedding Layer Of Mortar 20 Mm Thick For Laying Floor Finishes Complete All As Specified. 6 Providing And Laying Premium (1St) Quality Straight Edge, Ceramic Tiles Exterior Grade Scratch Resistance Of Size 300X300X7 To 8 Mm Thick In Floors Etc. In Any Shade And Design/Pattern Of Light & Dark Tiles Etc Set And Including 15 Mm Thick Rendering In Cement Mortar (1:6) And Pointed In White Cement With Pigment To Match Complete All As Specified. 7 Taking Up Or Down Existing Steel Tubing And Connections, 15Mm Bore Complete All As Specified. 8 S&F For Cpvc Pipe Fixed On Wall/Ceiling Or Laying In Floor Of 15Mm Bore Incl Fittings Complete All As Specified And Directed. 9 Taking Up Or Down Existing Steel Tubing And Connections, 20Mm Bore Complete All As Specified. 10 S&F For Cpvc Pipe Fixed On Wall/Ceiling Or Laying In Floor Of 20Mm Bore Incl Fittings Complete All As Specified And Directed. 11 S&F In Repair Angle Stop Cock With Wall Flange 15Mm Cast Copper Alloy, Screwed For Iron Pipe Or For Brass Ferrule Long Body.Make: Jaquar Cat Part No-Fon-40053Pm Or Equivalent In /Hindware/Kohlar. 12 S&F In Repair 15 Mm Bore Bib Cock With Wall Flange, Cast Copper Alloy, Chromium Plated, Fancy Type With Screwed Down, Screwed For Iron Pipe Or For Brass Ferrule Long Body.Make: Jaquar Cat Part No Opp-15037Pm Or Equivalent In/Hindware/Kohlar. 13 S&Fin Repair Brass Chromium Plated Basin Mixer For Mixing Hot & Cold Water Screwed Down For Iron Pipe Of 15Mm Bore All As Specified And As Directed. Make: Jaquar Cat Part No Orp-10011Bpm Or Equivalent In /Hindware/Kohlar 14 S&F In Repair 15Mm Cp Connection 600Mm Long Including Washer And Brass Nuts All As Specified. 15 S&F In Repair Europen Wc China Ware Coloured Cascade With Cistern And Complete Fitting.Make: Jaquar/Hindware/Kohlar 16 S&F In Repair Counter Top Wash Basin Of Size 600 X465Mm With Wash Basin Cabinet Size 600X455X600Mm Including Bottle Trap , Brass Waste Fitting Complete All As Specified. Make:-Cera/Hindware/Jaguar 17 S&F In Repair Toilet Roll Holder Stainless Steel Flap All As Specified. Make- Jaquar Cat Part No Can-1153S Or Equivalent In /Hindware/Kohlar 18 S&F In Repair Towelrack 600Mm Long With Lower Hanger (Stainless Steel) All As Specified.(Make: Jaquar Cat Part No Acn -1181S Or Equivalent In /Hindware/Kohlar 19 S&F In Repair Soap Dispenser With Glass Bottle (Stainless Steel) All As Specified. Make- Jaquar Cat Part No Acn -1135N As Equivalent /Hindware/Kohlar 20 S&F In Repair Soap Dish Holder With Glass (Stainless Steel) All As Specified. Make- Jaquar Cat Part No Akp -35731P Or Equivalent In /Hindware/Kohlar 21 S&Fin Repair Towel Ring Square With Round Flange (Stainless Steel) All As Specified. Make- Jaquar Cat Part No Acn -1121N Or Equivalent In /Hindware/Kohlar 22 S&F In Repair Healthfaucet With 1Mtr Long Easy Flex Tube In Chrome Finish And Wall Hook Of 15 Mm Bore With Cp Pipe Complete Set Of Make -Jaquar Cat Part No Ald - 565 Or Equivalent In Parryware/Prayag 23 S&F In Repair Looking Mirror 5Mm Thick Size 3.5X3.5 Feet Incl Stud And Fastners Complete All As Specified And Directed. 24 S&F In Double Arm Wall Mounted Reversible Plain/Magnifying (X3) Pivotal Mirror All As Specified. Jaquar Cat Part No Acn -1193N Or Equivalent In /Hindware/Kohlar 25 S&F In Repair Glass Shelf Corner With Bracket Of Size 225Mm X 225Mm Thickness Of Glass 6Mm) With Cp Brass Railing And Brass Screws.Make- Jaquar Cat Part No Acn -1173 Or Equivalent In /Hindware/Kohlar 26 S&F Grating Doom 125Mm Of Ptmt. 27 S & F In Repair Vitreous China Urinal Half Stall Type White (Excluding Flushing Cistern ) Including Waste Fitting, Waste Pipe Complete All As Specified.Make-Jaquar/Hindware/Kohlar 28 S&F Ms Work In Tubular/Pipe/Angle Sections For Frame Work For Roof, Vertical Poles, Rafters And Purlins Including Washer Etc Complete All As Directed. 29 S & F Pre-Painted Galvalume Aluminum Zinc Coating Gi Based Corrugated Steel Sheet 0.50 Mm Thick Of An Colour Having Tensile Strength Of 550 Mpa As In Roof Covering/Cladding To Wall,Fixed With Self Tapping Screws As Specified. ( Design Of Sheet As Mangalore Tiles Pattern In Red Colour ). 30 S & F Pre-Painted Galvalume Aluminum Zinc Coating Gi Based Plain Steel Sheet 0.50 Mm Thick Of An Colour Having Tensile Strength Of 550 Mpa As In Roof Covering/Cladding To Wall,Fixed With Self Tapping Screws As Specified. 31 M & L Two Coats Of Synthetic Enamel Paint Over A Coat Of Red Oxide Primer Incl Preparation Of New Surfaces Of Any Description Over 10 Cm Width Or Girth Complete All As Specified And As Directed. 32 M&L 25Mm Thick Factory Made Coloured Interlocking Designer Polished Floor Tiles (Ultra Pattern) Of Grade M-35 Of Shape And Size As Directed,And 100Mm X 100Mm Size Tiles Piece On Every Joint Of Tiles Flooring Laid Over & Including 20Mm Thick Screed Bed In Cement Mortar 1:4 Complete All As Specified And Directed . Note: Sample Shall Be Got Approved From Ge Before Commencement Of Work 33 S&F In Repair Stainless Steel Drapery Rod Of 20 Mm Inner Dia (In Lengths As Directed) Of & Including Decorative Finial At Both Ends And Pair Of S S Steel Brackets Fixed At Both Ends With Pvc Rawl Plug & Steel Screws On Walls/Beam, (Victorian Design)All As Specified & As Directed. Make -Sample Can Be Seen In The Office Of Engg-In-Charge For Checking And Quoting The Same 34 Demolition Of Cement Concrete Un -Reinforced In Ground Floors And Pavings N.Exc 15Cm Thickness Complete All As Specified. 35 M& L For 25Mm Thick Pcc 1:2:4 Type Bo Using 12.5 Mm Graded Stone Aggregate As In Floor Complete As Specified And Directed. 36 S & F 75 Mm Dia Pvc ( Swr ) Floor Trap, Plain With Grating Including Jointing With Solvent Cement Complete All As Specified. 37 S & F Floor Door Stopper Of Aluminium Alloy And Tongue, Anodised With Hard Drawn Steel Overall Length Of Cover Plate 140Mm.As In Repairs Complete All As Specified. 38 Dismantling Of Wall And Ceiling Board(Fiblre, Pulp, Insulation Etc) Any Thickness Including Cover Fillets Complete All As Specified And As Directed. 39 S & F Powder Coated Aluminum Alloy Interlocking Snap Grid Frame Work For False Ceiling Size 600Mm X 600Mm Consists Of Main Tee Runners Of Size 38Mm X 38Mm X 1.5Mm And Cross Tee Of Size 38Mm X 38Mm X 1.5Mm, Spaced Between The Main Tee At 600Mm Centre To Centre To Form A Grid Of 600Mm X 600Mm Complete All As Specified And As Directed And As Per Manufacturer. Instruction. 40 M & L For 4Mm Thick Non Asbestos Fibre Cement Building Boards Of Make E Board Classic Designer Board (Cascade Or Occenic) Of M/S Everest Industries Ltd Or Equivalent As Approved, By Ge Fixed Or Laid/ Inserted To Timber/Gi/Aluminium Framework With Complete All As Specified And As Directed. 41 Taking Down Cement Mortar Plastering On Brick Or Stone Walls, Etc. Including Raking Out Joints,Hacking For Key,Scrubbing Down With Water, Etc Complete All As Specified And As Directed. 42 M&L For Rendering 15Mm (In Two Layers 10Mm+5Mm) Thick Plaster In Cm (1:4) On Faces Of Brick Work Or Concrete Surfaces, Finished Even And Smooth Without Using Extra Cement Complete All As Specified And As Directed. 43 M&L For Rendering 5Mm Thick Plaster In Cm (1:3) On Faces Of Brick Work Or Concrete On Surfaces Of Ceiling, Finished Even And Smooth Without Using Extra Cement Complete All As Specified And As Directed. 44 Complete Removal Of Existing Treatment Including Washing Rubbing Down And Stopping Of Painted Surfaces And Applying 1-2 Mm Thick Metallic Texture Painting (Top Quality) On Walls In Any Colour/Shade/Pattern/Design Including Preperatory Work For Base By Applying Primer/Putty Coat By Any Authorised Applicator Complete All As Specified And Directed 45 M&L For New Plaster Surfaces And Applying 1-2 Mm Thick Metallic Texture Painting (Top Quality) On Walls In Any Colour/Shade/Pattern/Design Including Preperatory Work For Base By Applying Primer/Putty Coat By Any Authorised Applicator Complete All As Specified And Directed 46 M&L For Preparing New Plastered Or Unplastered Surfaces Of Ceiling, And Applying Three Coats Of White Wash Complete All As Specified And Directed. 47 M & L For Cement Concrete As Pcc 1:5:10 Type E-2 Using (40Mm Graded Stone Aggregate) As Foundations,Filling And Mass Concrete Complete All As Specified. 48 M&L For 75 Mm Thick Pcc 1:3:6 Type C-1 (Using 20Mm Graded Stone Aggregate) As In Plinth Protection/Floors Complete All As Specified And Directed. 49 Demolition Of Brick Work Or Stone/Boulder Masonary, Laid In Cement Mortar Or Cement Lime Mortar Complete All As Specified. 50 M&L Brick Work, Straight Or Curved On Plan N.Exc 6M Mean Radius In Cm 1:6 Using Old Size Brick Complete All As Specified. 51 Taking Down Chowkat Or Frame With Shutters (With Out Taking Off Shutter From The Frame ) Not Exceeding 1.5 Sqm Each As Directed By Engineer-In-Charge. 52 S&F For Factory Made Single Extruded Wpc (Wood Polymer Composite) Solid Door Frames/Chowkhat Comprising Of 100 Mm X 65 Mm Size, Applying Pvc Solvent Cement And Screwed With Full Body Threaded, Star Headed Ss Screws Having Minimum Frame Density Of 750 Kg/Cum And Resistance To Spread Of Flame Of Class A Category With Property Of Being Termite/Borer Proof, Water/Moisture Proof And Fire Retardant And Fixed In Position With Mild Steel Hold Fast/Lugs/Ss Dash Fasteners Of Required Dia And Length Complete All As Specified And As Directed By Engr-In-Charge. 53 S&F 28-30 Mm Thick Moulded Wpc Factory Made 100% Solid Door (Conforming As Per Is-4020) Made From 100% Lead Free Single Extruded With 2, 4 Or 6 Raised Panel Design On The Front Side With 10 Mm Deep Mould On Single Side With Wood Grain Texture And Back Side Palin With Density Not Less Than 600 Kg/Cum. Manufactured By An Iso : 9001-2015 Certified Company. The Door Should Be Water Proof, Termite Proof, Fire Etardant And Having Screw Holding Capacity Complete All As Specified 54 S&F Stainless Steel (304 Grade) Finished Butt Hinges 125Mm Complete All As Specified And Directed 55 S & F Extruded Brass Handles, Fabricated Type Polished 150 Mm Complete All As Specified. 56 S & F Brass , Barrel Tower Bolts, With Cast Or Sheet Barrel And Rolled Or Cast Bolts And Fixed 200 Mm Complete All As Specified. 57 M&L For 250Mm Long Brass, Sliding Door Bolt Withsand Or Die-Cast Brass Hasp, Staple (Bolt Type) And Fixing Bolt With Rolled Or Drawn Brass Bolts And Fixed Complete All As Specified And As Directed. 58 Dismantling Pvc Pipes With Fittings Upto 75Mm To 110Mm Dia Complete All As Specified And Directed By Engr-In Charge.. 59 S&F For Pvc (Swr) Pipe 110 Mm Dia Single Socketed In Any Length With Rubber Ring Jointed Level Fixed To Walls Complete All As Specified And As Directed. 60 S&F For Pvc (Swr) Pipe 75 Mm Dia Single Socketed In Any Length With Rubber Ring Jointed Level Fixed To Walls Complete All As Specified And As Directed. 61 S&F For Pvc (Swr) Bends With Access Door 110 Mm Dia Complete All As Specified And As Directed. 62 All As Per Item No 61 Above But 75 Mm Dia. 63 S&F Pvc (Swr) Plain Bend 110 Mm Dia Complete All As Specified And As Directed. 64 S&F Pvc (Swr) Plain Bend 75 Mm Dia Complete All As Specified And As Directed. 65 S&F Pvc (Swr) Branch Piece Single Or Double T Equal Or Unequal With Access Door 110 Mm Dia Complete All As Specified And As Directed. 66 All As Per Item No 65 But 75 Mm Dia. 67 S&F Pvc (Swr) Vent Cowl 110 Mm Dia Complete All As Specified And As Directed. 68 Excavating In Post Holes (Or Similar Holes) Each N Exc 0.5 Cum, Getting Out, Returning, Filling In And Ramming Earth Or Broken Rubble Mixed With Earth Around, In Layers Not Exceeding 25Cm, Watering, And Removing Surplus Soil To A Distance N Exc 50 M And Making Good Surface 69 M&L For Cutting Chases, Pinning In, Making Good To Facings Where Required And Pointing In Cement Mortar 1:3 To Ends Or Edges Of Landings, Steps, Cills, Sunshades, Shelves, Lintels, Etc.; And Cutting Chases For Concealed Water Tubing Or Concealed Conduit Wiring, Etc. And Making Good, Cutting Not Exc 10 Cm Girth All As Specified. 70 Taking Down Carefully Existing Points Wiring On Surface Conduit/Concealed Conduit Including Conduit From Surface And Expect Conduit In Concealed Wiring For Light/Fan/Socket/Power/Bell From Wall & Roof Along With Fitting And Fixtures Such As Switches, Sockets, Ceiling Roses, Batten Holders, Unserviceable Light Fittings, Pieces Of Wires, Gutties, Conduit, Wooden Boards Etc Removing Materials To Store For Keeping In Safe Custody Of Contractor For Which The Credit Has Been Considered Under Schedule Of Credit And Making Good The Disturbed Portion Of All Floor, Ceiling Etc All As Specified And Directed. 71 M & L For Point Wiring With 1.5 Sqmm Pvc Insulated And Unsheathed Frlsh Single Core Multistranded Copper Conductor For One Light/Fan/Bell Point In And Including New Pvc Rigid Non Metallic Concealed Conduit 19/20 Mm Dia, Medium Duty, Isi Marked To Be Terminated In Pressed Steel Terminal Boxes With Pvc Modular Top Cover Plates Of Suitable Size For Mounting Of Modular Type Switches/Sockets/Regulators Including 1.5 Sqmm Pvc Insulated And Unsheathed Frlsh Single Core Multistranded Copper Earth Continuity Conductor Controlled By One Switch And/Or One Regulator Complete Including Cutting Chases And Making Good The Surfaces In Cm 1:3 And Finishing The Surface As Per Existing Treatment All As Specified And Directed By Engr-In-Charge.Notes: (I) Cost Of Pressed Steel Terminal Boxes And Modular Top Cover Plate Shall Be Included In Point Wiring. (Ii) Wiring Shall Be Done As Per Colour Code In Is For Phase, Neutral And Earth.(Iii) -Cost Of Eye/Bottle Thimbles Used For Connection In Switches/Sockets & Mcbs In Dbs Shall Deemed To Be Included In The Unit Rate Quoted For This Item. 72 All As Per Sl Item No 71.00 Above Herein Before But One Socket Out Let 5 Pins 5 Amp On The Same Board With Other Switches Complete All As Specified And Directed. 73 All As Per Sl Item No 71.00 Above Herein Before But For One Socket Out Let 5 Pins 5 Amp On Independent Board Complete All As Specified And Directed. 74 All As Per Item No71.00 Herein Before But 2.5 Sqmm Pvc Insulated And Unsheathed Frlsh Single Core Multistranded Copper Conductor Incl 2.5 Sqmm Pvc Insulated And Unsheathed Frlsh Copper Earth Wire For Switch Socket Combination 3 Pin 15 Amps On Independent Board. 75 S & F In Replacement Of Modular Switch 1 Way, 6 Amps, 1 Module, 230 Volts Complete All As Specified. 76 S & F In Replacement Of Modular Switch 1 Way, 16 Amps, 1 Module, 230 Volts Complete All As Specified. 77 S & F In Replacement Of Modular Socket 5 Pin 6 Amps, 2 Module 230 Volts Complete All As Specified. 78 S & F In Replacement Of Modular Socket 5 Pin 6 &16 Amps, Combination Type 2 Module Complete All As Specified. 79 S & F In Replacement Of Modular Fan Regulator Step Type, 120 Watts, 2 Module Complete Fixed As In Repair All As Specified. 80 S & F In Replacement Of Ceiling Rose Surface Bakelite Surface 65 X 50Mm 3 Terminals All As Specified & Directed 81 Supply And Fix Incl Taking Down Deco Mini Energy Efficient 0.5 Watt B22 Base Led Bulb Green Colour With Colour Temperature 6500 Kelvin, Controller Type Push Button , Globe Shape For Indoor/ Outdoor Usage All As Specified And Directed By Engr In Charge. 82 Supply And Fix Incl Taking Down Deco Mini Energy Efficient 0.5 Watt B22 Base Led Bulb Red Colour With Colour Temperature 6500 Kelvin, Controller Type Push Button , Globe Shape For Indoor/ Outdoor Usage All As Specified And Directed By Engr In Charge. 83 Supply And Fix Surface/Recess Mounted Led Luminaire 36 Watt Cool White 4000-5000K Suitable For Gridd Celling Cutout Dimensions: 2X2 Ft. Incl Connecting With Twin Core Copper Wire From Ceiling Rose To Fitting, Fixture Size: (Lxwxh) In (595X595X65) Mm Incl Lamp And Driver All As Specified & Directed. 84 S & F In Replacement Tube Light Fitting Self Ballasted Led Batten. Extruded Thermoplastic Body With Pc Diffuser In Square Led Batten 18/20W 6500K Of Capacity ,20 Watt,4 Ft Long Incl 3 Core Flexible Wire 0.5 Sqmm Copper Cable All As Specified And Directed By Engr-In-Charge. 85 S & F In Replacement Tube Light Fitting Self Ballasted Led Batten. Extruded Thermoplastic Body With Pc Diffuser In Square Led Batten 9/10W 6500K Of Capacity ,10 Watt,2 Ft Long Incl 3 Core Flexible Wire 0.5 Sqmm Copper Cable All As Specified And Directed By Engr-In-Charge. 86 Supply And Fix Mirror Light With Linear & Compact 12 W Mirror Light With Decorative Grey End Caps, Polycarbonate Body And Ribbed Opal Diffuser Of Capacity 9 Watt Complete All As Specified And Directed By Engr-In-Charge. 87 M & L For Sub Main Wiring With Two Single Core 4.0 Sqmm Pvc Insulated And Unsheathed Frlsh ,Stranded Copper Conductor Cable Drawn Through Pvc Concealed Conduit 25 Mm Dia Including 4 Sqmm Pvc Insulated Unsheathed Frlsh Stranded Copper Conductor Cable As Earth Wire All As Specified And Directed By Engineer-In-Charge. Note 1:- 2 Runs Of 4.00 Sqmm Copper Conductor Cable, 1 Run Of Pvc Conduit & 1 Run Of 4.00 Sqm Copper Conductor Earth Wire Shall Be Measured As One Unit) Note2 : Rate Quoted For This Items Shall Be Inclusive Of The Cost Of (I) Rigid Non-Metallic Pvc Conduit Of 25 Mm Dia With Tees, Bends, Elbows, Reducers, Bell Mouth Tube Ends And Fixing Accessories Such As Couplers, Lock Nuts, Saddles, Pipe Hooks Etc. (Ii) Cutting Chases, Pinning In Making Good To Facing Where Required And Pointing In Cement Mortar 1:3 To Match The Existing Surfaces, Cutting Not Exc. 10 Cm Girth . (Iii) Taking Out/Down Existing Unserviceable Sub Main Wiring. 88 Taking Down And Refixing Of Ceiling Fan After Supply And Replacement Of Rubber Reel, Round Cover Plate Of Size 6 Inch Of Ceiling Fan Complete With Ms Split Clamp Two Nos, Nuts And Bolts Complete All As Specified And Directed By Engr-In-Charge. 89 Supply And Fix Exhaust Fan Ac Single Phase 230/240 V Of Size 250 Mm Sweep 900 Rpm Engineering Thermoplastic Body, High Efficiency Motor, Dynamically Balanced Blade For Better Performance And Corrosion-Resistant Powder Coated Metallic Finish Including Louver Complete All As Specified And Directed By Engineer-In-Charge. 90 Material And Labour For Making Hole Of Suitable Size For Exhaust Fan 250 Mm/ 300Mm Sweep In Wall For Grouting And Making Good The Surface Complete All As Specified And Directed By Engr-In-Charge. 91 Supply And Fixing Single Pole And Neutral Enclosure With A Two Pin And Earth Plug And Socket Complete With Mcb Spn 32 Amps, Complete All As Specified And As Directed By Engineer-In-Charge. 92 S&F Poly Coated Gi Frame Work As In Grid For False Ceiling Comprising Of Protected Gi Perimeter Channel 0.55 Mm Thick With Two Unequal Flanges Of 20 And 30Mm And Web Of 27Mm Fixed To Surrounding Wall Using Nylon Sleves And Screws At 450Mm Centre To Centre/Intermediate Chaqnnel 0.9Mm Thick Having To Equal Flanges Of 15Mm Each And Web Of 45 Mm Suspended From Soffit And Approx 900Mm Centre To Centre With Gi Cleat And Steel Expansion Fasterners With And Including Ceiling Section (Not Exc 1.2 Metre Length) Of 0.55Mm Thickness Having Kurled Web Of 50Mm And Flange Of 26Mm Each With Lips Of 10.5Mm Fixed To The Intermediate Channel With Connecting Clips Acorss The Intermediate Channel At 457Mm Centre To Centre And Hangers 6Mm Dia Gi (Upto 1200 Mm Length Adjusting Level Fixed To Roof Slabs By Means Of Ceiling Cleats Made Out Of Gi Flat 40 X3Mm Size 60Mm Long Complete With And Including 7Mm Thick Pvc Laminated Gypsum Tiles Of Size 595X595Mm Complete All As Specified & Directed 93 M&L For Complete Removal Of Existing Surfaces Of Walls Including Cornices, Pillasters Etc, And Applying Two Coats Of Obd Over And Incl A Coat Of Interior Wall Primer Over Wall Care Putty Complete All As Specified And Directed. 94 M&L For Complete Removal Of Existing Treatment On Walls And Applying 02 Coats Of Exterior Weather Emulsion Paint To External Walls/Rcc Surfaces/Soffits Of Chajjas/Roof Projections/Cantilevers/Balcony Etc Surfaces Over & Including A Coat Of Exterior Wall Primer And Over Wall Care Putty Complete All As Specified. 95 S&F Stainless Steel Tubing Of 25 Mm Dia Chromium Plated Min. 1.0 Mm Wall Thickness As In Curtain Rod Complete Incl S&F 02 Nos Stainless Steel Brackets/Finials Fency Type, Stops Fixed With Ss Screws Etc All As Specified & Directed.Note : For The Purpose Of Mesurement And Payment Running Length Of Curtain Rod Only Shall Be Considered. 96 Taking Down Chowkhats Or Frames Of Any Description Exc 1.5 Sqm And N. Exc. 4 Sqm Each (Without Taking Off Shutters From The Frame) Including Cutting Hole To Size For Receive Fresh Pcc Of Hold Fast And Making Good The Disturbed Surface Same Complete All As Specified And Directed. 97 S&F Factory Made Pressed Steel Frames Made Of Ms Sheet Of 1.20 Mm Thickness For Doors With One Or More Rebates Including Necessary Fixing Lugs, Hinges, Lock Strike Plate, Etc., Complete As Specified,Size 125X60Mm 98 M&L Pcc 1:3:6 Type C-0 In 12.5 Mm Graded Stone Aggregates Hold Fast Fillinng Inside Frame & Hold Fasts Etc Complete All As Specified 99 S&F Factory Made Flush Shutters 35Mm Thick Ply Construction, Bwp Confirming To Is 2202, Solid Core Construction, With Block Board Core And Plywood Face Panels Commercial Type On Both Sides With 6Mm Thick Lipping Frame To Match Including Supply And Fixing Following Items :(A) Mild Steel Butt Hinges 125Mm - 3 Nos. Per Leaf(B) Stainless Steel (304 Grade) Finished Tower Bolt 200Mm Long - 2 Nos Per Leaf(C) Stainless Steel (304 Grade) Finished Handles 150 Mm - 2 Nos. Per Leaf(D) Stainless Steel (804 Grade) Finished Sliding Bolt 250 Mm - 1 No. Per Leaf(E) Stainless Steel (304 Grade) Finished Floor Door Stooper - 1 Nos. Per Leaf. 100 S&F 35Mm Thick Glazed And Skelton Shutters Of 2Nd Class Hard Wood (Factory Made) Open Rebated And Divided To Receive Glass, Gauze Etc (Without Sash Bars) Edges Of Framing Plain, Chamfered Or Rounded Fitted With Cut And Mitred Beads For Securing Glass Etc Size Of Members Of Shutter As Specified In Ssr-91 Pt-1 Section 8 Clause 8.20(A), Kiln Seasoned And Chemically Pressure Treated All As Specified Including Stainless Steel 304 Grade Wire Cloth (0.36Mm Nominal Dia Of Wire And Average Width Of Aperture 1.40Mm) All As Specified And Including Supply And Fixing Following Items :(A) Stainless Steel (304 Grade) Finished Butt Hinges 125Mm - 3 Nos Per Leaf(B) Stainless Steel (304 Grade) Finished Tower Bolt 200Mm Long - 2 Nos Per Leaf(C) Stainless Steel (304 Grade) Finished Handles 150 Mm - 2 Nos Per Leaf(D) Stainless Steel (304 Grade) Finished Sliding Door Bolt/Aldrop 16X250Mm - 1 No Per Leaf (E) Stainless Steel (304 Grade) Finished Floor Door Stooper - 1 Nos. Per Leaf. 101 M&L For Two Coat Of Synthetic Enamel Paint (Finishing Coat) Over One Coat Of Pink Primer To New Wooden Surfaces Of Any Description Over 10 Cm Width Or Girth Incl Prepration Of Surfaces Complete All As Specified And Directed. 102 S&F 300Mm, Ordinary Rat Tail Rod Pattern Springs Including Roller And Roller Plate Complete All As Specified And Directed. 103 S & F In Replacement Of Ceiling Rose Surface Bakelite Surface 65 X 50Mm 3 Terminals All As Specified & Directed 104 S & F In Replacement Of New Generation Energy Saving And Environmental Friendly Long Life Led Building Security Light 1X35 Watts Made Up Of Pressure Die Cast Alluminium Housing With High Power Led As Light Source And Lense Embedded Pc Cover Having Top Opening Separate Driver Compartment With Ip65 Protection And Impact Resistance Of Ik07, With All Accessories Including Suitable Bracket With 32Mm Bore Light Grade Gi Pipe Bemd To Shape, Including Ms Clamp Of Size Of Required Size And Pvc Cable 1.5 Sqmm Twincore From Ceiling Rose To Light Fittings Complete All As Specified And Directed By Engineer-In-Charge. 105 S & F In Replacement Of Surface Mounted Led Bulk Head Luminaire Of Capacity 10 Watt With Abs Body & Polycarbonate Diffuser, Ip54 Inc Connection With ,With Flexible Wire 0.5 Sqmm Copper Cable All As Specified & Directed By Engr-In-Charge. 106 Supply And Fix Lamp Holder Including Led Bulb 9 W Including Flexible Wire 0.5 Sqmm Copper Cable All As Specified & Directed By Engr-In-Charge. 107 M & L For Sub Main Wiring With Two Single Core 6.0 Sqmm Pvc Insulated And Unsheathed Frlsh ,Stranded Copper Conductor Cable Drawn Through Pvc Concealed Conduit 25 Mm Dia Including 6.0 Sqmm Pvc Insulated Unsheathed Frlsh Stranded Copper Conductor Cable As Earth Wire All As Specified And Directed By Engineer-In-Charge. Note 1:- 2(Two) Runs Of 6.00 Sqmm Copper Conductor Cable, 1 Run Of Pvc Conduit & 1 Run Of 6.00 Sqmm Copper Conductor Earth Wire Shall Be Measured As One Unit) Note 2 :(I) Rate Quoted For This Items Shall Be Inclusive Of The Cost Of (I) Rigid Non-Metallic Pvc Conduit Of 25 Mm Dia With Tees, Elbows, Reducers, Bell Mouth Tube Ends And Fixing Accessories Such As Couplers, Lock Nuts, Saddles, Pipe Hooks Etc. (Ii) Cutting Chases, Pinning In Making Good To Facing Where Required And Pointing In Cement Mortar 1:3 To Match The Existing Surfaces And Cutting Not Exc. 10 Cm Girth . (Iii) Including Taking Out/Down Existing Unserviceable Sub Main Wiring. 108 S & F In Replacement Of Sheet Metal Enclosure Db Tpn 4 Ways Double Door 415 Volts With 200 Amps Standard Bus Bar Of Suitable Size And Common Neutral Link Flush Mounting Type, Drilling Holes For Incoming And Out Going Cables Complete With Ip-43 Protection Complete All As Specified And Directed By Engr-In-Charge 109 S & F In Replacement Of Mcb, Triple Pole & Neutral (Tpn) 10 Ka 240 Volts 40 To 63 Amp Capacity Fixing In Db’S Complete All As Specified And Directed. (Note: Mcb Should Be B Or C Curve As Directed By Engineer In Charge) 110 Supply And Fix In Replacement Of Sheet Metal Enclosure 8 Ways Double Door For Dbs When Mcbs Are To Be Used 240,Volts Including 200 Amps Standard Bus Bar Of Suitable Size And Common Neutral Link All Flush Mounting Type, Drilling Holes For Incoming And Out Going Cables With Ip43 Protection Complete All As Specified & Directed By Engr-In-Charge. 111 S & F In Replacement Of Mcb, Single Pole 240 Volts 6 To 32 Amp Capacity For Fixing In Db’S Including Proper Thimble Connections Complete All As Specified And Directed By Engineer-In-Charge. 112 Supply And Fix In Replacement Of Mcb , Spn, 240 Volts ,40-63 Amp For Fixing In Dbs Of Including Proper Thimble Connections Complete All As Specified And Directed By Engineer-In-Charge. 113 M & L In Replacement Of Unsv Earthing Complete With Galvanized Iron Earth Plate Electrode Of Size 600X600X6.0Mm , Buried Directly In Ground (Earth Pit Not Less Than 2.25 Mtrs Below Normal Ground Level) With Top Edge Of Earth Plate Not Less Than 1.5 Mtr Below Normal Ground Level, Connected To Galvanized Earth Lead Wire 4.0 Mm Dia By Means Of Bolts , Nuts , Check Nuts And Galvanized Iron Or Steel Including Earth Work In Any Type Of Soil, Charcoal Salt 15 Cm Around The Earth Plate 20 Mm Dia Watering Pipe Medium Grade 1.70 Mtr Long With A Plug At Top, Gi Protection Pipe Light Grade 15 Mm Dia From Earth Pit To Main Board Including Pcc Pit In Cement Concrete 1:2:4 Along With Ci Frame And Cover 10Mm Thick Duly Hinged To Ci Frame As Shown In The Electrical Plate No3 Of Ssr 2009 Part 1 Specification At Page 497. 114 Xlpe Insulated ,Screened, Pvc Bedded, Galvanized Steel Wire Armoured, Electric Power Cables (Heavy Duty) 1100 Volts Grade With Stranded Aluminium Conductor Of Size 25 Sq Mm 4 Core Supplied & Laid In Replacement Complete All As Specified& Directed By Engineer-In-Charge. 115 Excavation In Trenches Not Exceeding 1.5 Mtr Wide And Not Exceeding 1.5 Mtr In Depth For Laying Of Cables Including Getting Out In Any Kind Of Soil Complete All As Specified And Directed. 116 Returning Filling In Including Spreading, Levelling, And Well Ramming, In Layers Not Exceeding 25 Cm Each Layer Of Any Kind Of Soil. 117 Removing Surplus Excavated Material From Site Not Exceeding 50 Mtrs From Starting Point And Depositing Where Directed At Level Not Exceeding 1.5 Mtr Above The Starting Point. 118 Material And Labour For Sand Cushioning For Cables 8 Cm Below The Cable And 15 Cm Above With Dry River Sand In Trenches For Cushioning Of Underground Cable Line Including Spreading, Leveling, Well Ramming Completed All As Specified And Directed. 119 Cutting Of Hardstanding Floor/Wall For Laying Of Cable Including Matching With Suface By Using Cement Concrete All As Specified And Directed. 120 Supplying & Laying Factory Made Unreinforced Precast Concrete Cable Covers Class Lv Type 1, Flat, Size 250X150X40Mm Laid In Trenches As Protection To Cables Complete All As Directed By Engr-In-Charge 121 Material And Labour For Replacement Of Gi Tubing Light Grade 40 Mm Bore For Passing Through Cables Under The Floor ,Along The Wall Or Along The Pole Complete All As Specified And Directed. 122 Dismantling Of Stone Slab And Tiles Laid Bedded And Pointed In Any Mortar Description Or Thickness In Floors, Apron Etc Complete All As Specified. 123 M & L For Screed Bed Or Bedding Layer Of Mortar 15 Mm Thick In Cm 1:6 For Laying Floor Finishes Complete All As Specified. 124 M&L For Virified Ceramic Light Shade Tiles 8 - 10 Mm Thick (Square/ Rectangular) Polished, Area Of Each Tiles Not Exceeding 0.36 Sqm, In Floors Etc,Over & Including 15 Mm Thick Screed In Cement Mortar (1:4) Over And Epoxy Cartridge Tile Grout Using Fill The Joint Of Tiles Complete All As Specified.Note- Epoxy Black,Golden Colour. 125 All As Per Item No 124 But As A Skirting Incl. 10Mm Thick Rendering As In Back Coat Complete All As Specified. 126 M&L For 7 To 8 Mm Ant-Skid Ceramic Joint Free Premium Quality Coloured Tiles Area Of Each Tile Esc 0.06 Spm But Next 0.11Sqm, As In Floors Etc. In Any Pattern Ghe & Dark Tiles As Approved, Set And Jointed In Neat Cement Slurry And Pointed In White Or Coloured Cement To Match, In Floors Etc. Over & Including 15 Mm Thick Screed In Cement Mortar (1:4) Over And Pointed In White Cement With Pigment To Match The Colour Of Tiles Complete All As Specified. 127 M & L For Machine Cut Cudappa Stone Slab 20 - 25 Mm Thick Laid Over Cement Screed Base 15Mm Thick In Cm 1:6 And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab Including Rubbing And Polishing Complete All As Specified. 128 Rounding To Edges Of Stone Slabs One Edge, Such As In Steps, Cooking Platform, And Other Similar Situations All As Specified. 129 Dismantling Water Tanks And Removing To Store Of Capacity Exc 500 & Not Exc 1000 Ltrs Complete All As Specified. 130 Supply And And Fixing, Hoisting Pvc Tank Of 1000 Ltr Capacity Including Supplied And Fixed 20Mm Dia Ptmt With Epoxy Coated Aluminium Rod And High Density Plastic Ball Screwed For Iron Pipe And Fixed.(Minimum Weight 15Mm-142 Gms/20Mm-210Gms/25Mm-455 Gms/40Mm-690 Gms Float Valve Assembly Complete All As Specified And Directed. 131 S&F In Repair Wall Mixture Mixing Valves Incl. Three Joints To Steel Pipes Or Unions 15 Mm Bore Fancy Type Best Quality As Per Sample Approved By Ge Make-Jaquar Cat Part No Qqp-7217Pm Or Equivalent In Hindware/Kohlar. 132 S&F Pvc Cabinet 600X450Mm Overall Size With Looking Mirror Of Selected Qality Glass Mountedover Pvc Framing As Per Sample Complete Fixed In Repair Complete All As Specified. 133 S&F Stainless Steel Plate Rack Of Size Not Less Than 90Cmx75Cm(Wt N. Less Than 4 Kg) Fixed With Stainless Steel Screw Including Taking Out Old Unserviceable Wooden Plate Rack As Approved By Ge Complete All As Specified. 134 S&F In Repairs Chromium Plated Shower Roses With Swivel Joints 125 Mm Dia Size Incl Fixing To Gi Pipe/Union Fixed Make-Jaquar /Hindware/Kohlar. 135 M & L For Rendering 15 Mm Thick On Fair Faces Of Brick Work Or Concrete Surfaces In Cement Mortar 1:6 Finished Even And Smooth ( Without Using Extra Cement ) With Sagol Finish On Plastered Surface Complete All As Specified And As Directed. 136 M&L For Preparation Of New Decorated Plastered Or Unplastered Surfaces Of Walls And Applying Two Coats Of Exterior Emulsion Over One Coat Of Primer And Over 2Mm Thick Putty For Levelling And Smoothening, Complete All As Specified And Directed. 137 M&L Preparation Of New Plastered Surface Of Walls And Applying Two Coats Of Oil Bound Distemper Over 1.5Mm Thick Wall Care Putty Complete All As Specified And Directed. 138 M&L For Preparing New Plastered Or Unplastered Surfaces Of Ceiling, And Applying Three Coats Of White Wash Complete All As Specified And Directed. 139 S&F Sinks With Drainage Board Made Of Stainless Steel Lmm Thickkitchen Or Laboratory With Plugs,Washers And Wastes; Including Bedding In Cement Mortar To Dwarf Wall Or Including Fixing Cantilever Brackets And Connecting Union To Pipe Overall Size 915Mm X 460Mm Bowl Size 410Mm X 330Mm X 160Mm Complete All As Specified And Directed. 140 S&F In Repair Brass Chromium Plated Sink Mixer For Mixing Hot & Cold Water Screwed Down For Iron Pipe Of 15Mm Bore All As Specified And As Directed. Make: Jaquar /Hindware/Kohlar 141 S&F Powder Coated Anodised Aluminium Frame For Doors, Windows Ventilators With One Or More Rebates Including Joining Cleat For Fixing Etc. Complete All As Specified And Directed. 142 S&F Frosted Glass 4.00Mm Thick Ordinary Quality And Glazing With Oil Putty In Square N.Exc 0.50Sqm In Each Panes Complete All As Specified And Directed. 143 S&F 28-30 Mm Thick Moulded Wpc Factory Made 100% Sketon/Glased Door (Conforming As Per Is-4020) Made From 100% Lead Free Single Extruded With 2, 4 Or 6 Raised Panel Design On The Front Side With 10 Mm Deep Mould On Single Side With Wood Grain Texture And Back Side Palin With Density Not Less Than 600 Kg/Cum. Manufactured By An Iso : 9001-2015 Certified Company. The Door Should Be Water Proof, Termite Proof, Fire Etardant And Having Screw Holding Capacity Complete All As Specified 144 S&F Factory Made Wpc Extruded Board Cnc Machine Cut Jali Fixed To Skelton Door As Per Approved Design Complete All As Specified And Directed 145 S&F Kitchen Cabinets Including All Fittings And Fixtures Incl The Follwing. (A) 19Mm Thick Plywood Of Commercial Block Board,Make: Kitply/Century Ply/ Green Ply(B) 1Mm Thick Commerical Lamination On Both Side Fixed To Black Board(Colour And Design As Approved)(C) Ss Pullout Basket Ss Finish Of Plain 15 X 20 X 6 (D) D Type Handle 100Mm Ss Finish(E) Pullout Basket Ss Finish Cutlery Wire Of Size 15X20X4 (F) 2Nd Class Hard As In Frame Work(G)Ss Channels For Pullout Basket As Required. (Note:- The Measurement Shall Be Taken From Front Elevation And Not Girthwise. 146 S&F Factory Made Upvc Brown Colour Door Shutter Made Of Extruded Profile With Wall Thickness Of 2.3Mm(+-0.2Mm) Door Profile With Hollow Section With Multy Chamber. Frame (60X62Mm),Sash(42Mmx67Mm).Sliding Interlock(One Verticle Length In Each Shutter)(45.5Mmx28Mm).Glazing Bead(24.5Mmx16Mm)Will Be Mittred Cut And Fusion Welded At All Corner.Including Drilling Holes For Fixing Hardware And Drainge Of Water Etc Am,.Making Arrangement For Fixing Of Hardware.Epdm Gasket,1.2+0.2 Mm Thick Galvanised Steel Frame(30Mmx21.5Mm).Sash (30Mmx18Mm)Profile To Be Inserted In Required Profile.Frame Will Be Finshed To The Wall With 8Mmx100Mm Long Fasteners.Hardware Touch Lockof Zinc Alloyed(Brown Powder Coated)Steel Roller System Including 5Mm Thick Glazing With Selected Quality Glass ,Aluminium Track And Bottom Rail For Two Track Sliding Fram,Wool Pine For Sliding Sash And Interlock. Note.The Unit Rate Coated By Contractor Includes Cost Of Glass And All Other Conncted Accessories,Net Opening Will Be Measured For Purpose.Make:H2O Window,Fenesta,Anuplast As Approved By Ge. 147 M&L For Rcc 1:2:4 Type B-1 Using 20Mm Graded Crushed Stone Aggregate In Any Situation Except Foundation Complete All As Specified And Directed. 148 S&F 10Mm Dia And Above Tmt Bars Cut To Length, Bend To Shape As Required Including Cranking, Hooking Ends & Binding With Mild Steel Wire (Annealed) Not Less Than 0.9Mm Dia Complete All As Specified And Directd. 149 All As Item No 77 Here In Before But 5Mm Dia And Over Upto & Including 10Mm Dia In Stirrups, Spaces & Binder Complete All As Specified And Directd. 150 S & F Powder Coated Aluminium Window/Ventilator Shutters, Side Hung Type With Sash Bars, Including Necessay Joinery Cleats, Glazing Clips, Rubber Packing, Chowkats Aluminium Snap Beading, Screws, Suitable Handle Etc With And Including Sheet Glass Or Ordinary Glazing Quality Of 4Mm Thick And Incl Gi Wire Mesh 0.56 Mm Nominal Dia Of Wire And Average Width Of Aperture 1.18 Mm , Size Of Side Rails , Top Rails , Bottom Rail 85X44.5Mm And Size Of Chowkat Frame 101.6X44.45Mm And Thickness Of Aluminium Member Shall Be 1.40Mm Thick Complete All As Specified. 151 S&F For Prelaminated Particle Board 18/19 Mm Interior Grade Prelaminated On One Side With Decorative Choice Lamination And Other Side Balancing White Lamination Fixed With Screw Timber Frame Work Including Dismantling Board All As Specified. 152 S&F In Repair Continuous (Paino) Hinges, Mild Steel, Bright Finish Or Electrogalvanised Width Of Flap (When Open) In 40Mm All As Specified. 153 S&F In Repair 40Mm Dia, Cupboard Knobs Fixed With Nut, Screw And Washer Of Mild Steel Bright Finished All As Specified. 154 S&F Ball Catches With 8Mm Dia Steel Ball And Brass Body And Striking Plate Including Letting In And Fixing Complete All As Specified. 155 Supply & Fix In Replacement Of Modular Bell Push Switch 1 Way, 6 Amps, 1 Module Complete All As Specified. 156 Supply & Fix In Replacement Of Call Bell Ding Dong Ac 230 Volt Single Pole Complete All As Specified. 157 Supply And Fix Exhaust Fan Ac Single Phase 230/240 V Of Size 300 Mm Sweep 900 Rpm Metal Body, High Efficiency Motor, Dynamically Balanced Blade For Better Performance And Corrosion-Resistant Powder Coated Metallic Finish Including Hole Making Louver Complete All As Specified And Directed By Engineer-In-Charge. 158 S & F Modern Energy Efficient Bedroom Muziris Wall Decorative Light Of Capacity 20 Watt Single Headed 240 Volt, Ip20 Rating, Controller Type (Push Button), Product Weight 1.04 Kg, Body Material (Metal), Power Source (Corded Electric),Lamp Base E27, Colour(Bronze) Incl Electrically Connection , Including Removing Of Unserviceable Decorative Light Fittings Of Any Description Complete All As Specified And Directed By Engr-In-Charge. Make: Philips Model No 31425 Or As Equivalent. 159 Excavating In Trenches N Exc 1.50M In Width And N Exc 1.50M In Depth For Foundation, Manholes Etc As Well As N Exc 10 Sqm On Plan Area And Getting Out In Soft/Loose Soil All As Specified And Directed. 160 M&L For Pcc 1:5:10 Type E-2, Using 40Mm Graded Crushed Stone Aggregate In Foundation, Filling And Mass Concrete All As Specified And Directed. 161 M&L For Broken Stone Hard Core Of Gauge N. Exc 63Mm, Deposited, Spread And Levelled In Layers N Exc 15Cm Thick, Watered And Rammed To A True Surface All As Specified And Directed. 162 S&F Mild Steel Deformed Bars, 6Mm To 8Mm Dia Cut To Length, Bent To Shape Required Including Cranking And Binding With & Including Mild Steel Wire (Annealed) Not Less Than 0-.90Mm Dia Complete. 163 M&L For Form Work To Soffits Of Suspended Slabs Such As Roof Slabs Etc For Rough Finished Concrete Surface Complete All As Specified And Directed. 164 M&L For Form Work To Sides For Slabs And Sides Of Rcc/Pcc Bands In Walls, Horizontal Or Sloping And Similar Work Exc 10 Cm But N Exc 20 Cm Wide For Fair Finished Concrete Surface Complete All As Specified And Directed. 165 Formwork To Sides Of Concrete Foundations, Footings, Bases Of Columns, Raft And Raft Beams, Sides And Soffits (If Any) Of Foundation And Plinth Beams And Similar Work, Vertical Or To Batter For Rough Finished Flat Surfaces Of Concrete. 166 Formwork To Sides Of Pillars, Posts, Struts, Piers, Columns And Stanchions, Square, Rectangular Or Polygonal For Rough Finished Flat Surfaces Of Concrete. 167 M&L For Rendering In Cement Mortar (1:6) 10 Mm Thick Finished Even Smooth Complete All As Specified On Brick Or Concrete Surface Of Fair Faces. 168 M&L 15Mm Thick Cement Plaster In Two Layer First Coat In Cm 1:6,10Cm Thick & Second Layer 5Mm Thick In Cm 1:4 Mixed With Wpc 3% By Weight Of Cement Including Finishing Fair & Even On Brick Or Concrete Surfaces Of Othern Than Fair Faces. 169 M&L For 5Mm Thick Cement Plastering To Rcc Surfaces In Cm :1:3) Finished Even And Smooth W/O Using Extra Cement On Ceiling Surfaces. 170 S&F Stainless Steel Butt Hinges Medium Weight Cold Rolled Isi Marked Of Size 100 Mm Complete All As Specified And Directed. 171 M&L For Ms Framed Guard Bars Conforming To Fe-410-0 Or Fe-310-0 Welded To Steel Windows/Ventilations Complete All As Specified And Directed. 172 S&F Vitrous China Squatting Pan Of Orissa Patterns Long Pan Size 580Mx440Mm White With P Or S Trap Front Of Back Inlet And Foot Rest Including Long Band Any Pattern (Excluding Flushing Cistern And Flush Pipe) Including Provision For Lime Concrete Bedding. 173 S&F Pvc Flushing Cistern Low Level 10 Ltr Cap With Inlet Ball Valve Float And Handle Syphonic Action Type Incl Brackets And Flush Pipe Of Polythene Of Low Or High Density Isi Marked. 174 S & F In Repairs Vitreous China Oval Shape Wash Basin, White, Flat Back, Size 580 X 450 Mm Excluding Taps, Waste, Chain And Plug And Porcelain Stopper But Including Brackets With 32 Mm Dia Waste Fittings, Brass, Chromium Plated With Waste Pipe Complete All As Specified. 175 S&F Looking Mirror Of Selected Quality Mounted On 6 Mm Thick Ply And Fixed To Wall With Wooden Plugs Chromium Plated Brass Screws And Washers. 176 S&F For Ci Floor Trap With Incl Jointing With Waste Pipe In Cement Mortar Of Size 100Mm. 177 S&F Gully Trap Stone Ware Square Of Round Mounted Type P Of Size 150X150Mm. 178 S&F 20Mm Dia Stop Valve Of Copper Alloy Screwed Down High Pressure With Crutch Or Butter Fly Handle Screwed On Both Ends For Iron Pipe Or For Union Fixed. 179 S&F Pvc Connection 15Mm Dia 600Mm Long Of Heavy Grade Screwed One End To Inlet Of Whb/Pillar Tap/Cistern Etc Complete Incl Brass Union Coupling On Both Ends Connfirming To Is-3076 Complete With Connector For Connection Old Water. 180 S& F For Ci Pipe 75Mm Dia Laid In Floor In Any Length With Or Without Cars With Cement Joint (Waste & Vent Pipe). 181 All As Per Item No 38 Here In Before But 100Mm Dia. 182 S&F For Ci Bend Any Radius Disminshing Pieces Or Tyes Of 100Mm Bore With Ducks For Or Head Rest. 183 S&F For Ci Branch Pieces Single Equal Or Unequal Ordinary Or Inverted Or With Paralled Brnach 100 Mm Bore. 184 S&F Cast Iron Sand Cast Pipe 100 Mm Dia With Or Without Cars With Cement Joint Fixed To Walls. 185 S&F Cast Iron 100 Mm Cowl. 186 M&L For Pcc 1:4:8 Type D-2 Using 40Mm Graded Stone Aggregate)75Mm Thick On In Sub Base Of Fllor .. 187 M&L For 15Mm Thick Screed Bed Or Bedding Layer In Cm 1:6 Complete All As Specified And Directd. 188 M&L For Coloured Glazed Ceramic Tiles On Vertical Surface (300Mmx600Mx7M) Thick Set And Jointed In Neat Cement Slurry And Pointed With White Cement To Match Complete All As Specified And Directd. 189 M&L For Coloured Non Skid Ceramic(300X300Mm) Tiles 7 To 8Mm Thick As In Floor Set And Jointed In Neat Cement Slurry And Pointed With White Cement To Match Complete All As Specified And Directd. 190 S&F Steel Ventilation With Top Hung Shutter Including Hinges, Steel Peg Stay Complete. 191 S&F 4Mm Thick Sheet Glass Of Figured,Pin Headed And Glazing With Oil Putty In Square N Exc 0.50 Sqm In Each. 192 M&L For Preparation Of Newly Steel Surfaces And Applying Two Coats Of Synthetic Enamel Paint Over A Coat Of Red Oxide Over 10 Cm Width Or Girth Complete All As Specified And Directd. 193 M&L For Preparation Of Newly Plastered Surfaces And Applying Two Coats Of Cement Base Paint Over A Coat Of Chalk Whiting Complete All As Specified And Directd. 194 M&L For Three Coats Of White Wash On Wall Of Newly Plastered Surface. 195 S&F For Preparation Of Newly Plastered Surfaces And Applying Three Coats Of White Wash On Ceiling. 196 M & L For Factory Made Solid Pvc Door Frame Of Size 50 Mm X 47 Mm Made Out Of 5 Mm Plain Colour Pvc Sheet Reinforced With M.S Square Tube, Supplying & Fixing In Opening As Per Specification & Drawing Complete All As Specified And As Directed. 197 S&F Factory Made Solid Pvc Moulded Door Shutter, With Particle Board Core, 28 To 30Mm Thick (Stiles), With 2, 4, Or 6 Raised Panel Design With 2Mm Thick Moulded Pvc Sheet On The Front Face & 2Mm Plain Colour Pvc Sheet On Back Face & 5Mm Thick Plain Colour Pvc Sheet On Back Face, Supplying & Fixing In Frame At Site As Per Specification & Drawing All As Specified. 198 S&F Aluminium Tower Bolt 150Mm Long Stove Enamelled Black With Bright Bolt & Fixed. 199 S&F Aluminium Sliding Door Bolt With Hasp And Staples Type Bolt Type , 300Mm Long Stove Enamelled And Fixing Clips Of Sheet Cast Or Extruded Section Or Cast Aluminium Alloy And Fixed All As Specified. 200 S&F Aluminium Alloy Handle Of 100M Size Oval Type Stove Enamelled & Fixed All As Specified. 201 M&L For Rendering 10Mm Thick Cm (1:4) On Roof Slab Top, Mixed With Water Proofing Liquid Finished Even And Fair Without Using Extra Cement Complete All As Specified. Note: Water Proofing Liquid Shall Be Measured And Paid Separately. 202 M & L For Cleaning The Newly Plastered Surfaces Of Concrete ( Roof Etc) With Wire Brushes And Applying Water Proofing Treatment As Under :-I) Apply One Coat Of Oil Bound Bituminous Primer @ 0.25 Kg/Sq.M Ii) Providing And Laying 3 Mm Thick App Modified Water Proofing Membrane Weighing Not Less Than 3.5 Kg / Sqm Reinforced With Non Woven Polyester Mat Weighing Not Less Than 160 Gm/Sqm All As Specified Procured From Any One Of The Approved ManufacturerS Iii) Apply One Coat Of Solar Reflective Bituminous Aluminium Paint @ 0.15 Kg/Sqm Over Membrane Over Non Assesble Roof Surfaces Complete All As Per ManufacturerS Instructions And As Directed . 203 M/L Brick Work In Cm1:4, In Half Brick Thick Wall. 204 S&F In Repair Europen Wc China Ware Coloured Cascade With Cistern And Complete Fitting.Make: Jaquar/Hindware/Kohlar 205 S/F Vitreous China Toilet Paper Holder Fixed To Walls With Chromium Plated Cp) Brass Screws 206 S/F Vitreous China Soap Dish Of Appx Size 160*160*90Mm Any Type Fixed To Plugs With Chromium Plated Brass Screws 207 S/F Sheet Glass Shelf Assembly Consistig Of 5.5Mm Thick Sheet Glass Shelf 12Cm Wide With Chromium Plated Brackets Guard And Railing 60Cm Long 208 S & F Brass Chromium Plated Tubular Towel Rail, 20 Mm Dia, D Type, 60 Cm Long Between Flanges Complete All As Specified. 209 M & L For Granite 20 Mm Thick Machine Cut, Bedded And Jointed With Grey Cement Slurry And Pointed With White Cement With Admixture Of Pigment To Match The Shade Of Granite Stone Including Griding And Polishing Types All As Specified. 210 M & L For Machine Cut Cudappa Stone Slab 20 - 25 Mm Thick Over Cement Screed Base Laid And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab Including Rubbing And Polishing Complete All As Specified. 211 M&L For 75 Mm Thick Pcc 1:3:6 Type C-1 (Using 20Mm Graded Stone Aggregate) As In Plinth Protection/Floors Complete All As Specified And Directed. 212 S&F Health Faucet Including Ms/Anodised Hanging Device Fixed Complete All As Specified And As Directed. 213 Surface Excavation Not Exceeding 30Cm Deep And Averaging 15Cm Deep And Getting Out In Loose / Soft Soil All As Specified And Directed. 214 M&L For Broken Stone Hard Core Of Gauge N. Exc 63Mm, Deposited, Spread And Levelled In Layers N Exc 15Cm Thick, Watered And Rammed To A True Surface All As Specified And Directed. 215 M & L 100Mm Thick Pcc 1: 4: 8 Type D2 (Using 40Mm Graded Stone Aggregate) As In Sub Base Complete All As Specified And Directed. 216 M&L For Machine Pressed Precast Concrete Interlocking Paver Block Rubber Moulded Any Shape And Size Confirming To Is 15658-2006 Of 60Mm Thickness, M-35 Grade With Grey And Pigment As In Floor/Pavement Complete All As Specified And As Directed. 217 M&L For Providing Precast Concrete Type C-1, 1:2:4(Using 20Mm Graded Stone Aggregate) As In Kerb Blocks With Plain Fiar Faces, Including Chamferes, Weathering, Throating Etc And Setting In Mortar 1:4 Complete With Joints To Match. 218 M&L For Cement Concrete Type 1:4:8 Type D-2 (Using 40Mm Graded Stone Aggregate) As In Foundations, Filling And Mass Concrete Complete All As Specified And As Directed. 219 M & L For Sand Filling Under Floors Or In Foundation Including Watering And Consolidation 220 S & F In Replacement Of New Generation Energy Saving And Environmental Friendly Long Life Led Building Security Light 1X25 Watts Made Up Of Pressure Die Cast Alluminium Housing With High Power Led As Light Source And Lense Embedded Pc Cover Having Top Opening Separate Driver Compartment With Ip65 Protection And Impact Resistance Of Ik07, With All Accessories Including Suitable Bracket With 32Mm Bore Light Grade Gi Pipe Bemd To Shape, Including Ms Clamp Of Size Of Required Size And Pvc Cable 1.5 Sqmm Twincore From Ceiling Rose To Light Fittings Complete All As Specified And Directed By Engineer-In-Charge. 221 S & F In Replacement Tube Light Fitting Self Ballasted Led Batten. Extruded Thermoplastic Body With Pc Diffuser In Square Led Batten 9/10W 6500K Of Capacity ,10 Watt,2 Ft Long Incl 3 Core Flexible Wire 0.5 Sqmm Copper Cable All As Specified And Directed By Engr-In-Charge. 222 M&L For Boring Of Holes Under Road, Pavement, Hard Standing By Trench-Less Technology Using Ultrasound Technique And Necessary Machine Suitable To Pass Through 40 To 80 Mm Bore Gi Tubing And Cable Etc Complete All As Specified And Directed.Note: Gi Pipe Shall Be Measured And Paid Seperately Under Relevant Item.
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 8
4.
Science and Technology #11440503 Technical Bid
Tender for Earth Work , Earth Work In Excavation By Mechanical Means (Hydraulic Excavator) / Manual Means In Foundation Trenches Or Drains (Not Exceeding 1.5 M In Width Or 10 Sqm On Plan), Including Dressing Of Sides And Ramming Of Bottoms, For All Lift, Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soil As Directed, Within A Lead Of 50 M.All Kinds Of Soil. , Filling Available Excavated Earth (Excluding Rock) In Trenches, Plinth, Sides Of Foundations Etc. In Layers Not Exceeding 20Cm In Depth, Consolidating Each Deposited Layer By Ramming And Watering, Lead Up To 50 And For All Lif. , Excavating, Supplying, Stacking And Filling Of Local Earth (Including Royalty) By Mechanical Transport Upto A Lead Of 5Km Also Including Ramming And Watering Of The Earth In Layers Not Exceeding 20 Cm In Foundation Trenches, Plinth, Sides Of Foundation Etc. Complete For All Lift. , Cement Concrete (Cast In Situ) , Providing And Laying In Position Excluding Cement Concrete Of Level: Specified Grade The Cost Of Centering And Shuttering - All Work Up To Plinth 1:4:8 (1 Cement : 4 Coarse Sand (Zone-Ill) Derived From Natural Sources: 8 Graded Stone Aggregate 40 Mm Nominal Size Derived From Natural Sources) , Providing And Laying Cement Concrete In Retaining Walls, Return Walls, Walls (Any Thickness) Including Attached Pilasters, Columns, Piers, Abutments, Pillars, Posts, Struts, Buttresses, String Or Lacing Courses, Parapets, Coping, Bed Blocks, Anchor Blocks, Plain Window Sills, Fillets, Sunken Floor Etc., Up To Floor Five Level, Excluding The Cost Of Centering, Shuttering And Finishing: 1:2:4 (1 Cement : 2 Coarse Sand (Zone-Ill) Derived From Natural Sources : 4 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources) , Reinforced Cement Concrete , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For Foundations, Footings, Bases Of Columns, Etc. For Mass Concrete , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For Suspended Floors, Roofs, Landings, Balconies And Access Platform , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For Lintels, Beams, Plinth Beams, Girders, Bressumers And Cantilevers , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For Columns, Pillars, Piers, Abutments, Posts And Struts , Steel Reinforcement For Reinforced Cement Concrete Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Upto Plinth Level.Thermo-Mechanically Treated Bars Of Grade Fe-500D Or More. , Steel Reinforcement For Reinforced Cement Concrete Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Above Plinth Level.Thermo-Mechanically Treated Bars Of Grade Fe-500D Or More. , Providing And Laying In Position Ready Mixed Or Site Batched Design Mix Cement Concrete For Reinforced Cement Concrete Work; Using Coarse Aggregate And Fine Aggregate Derived From Natural Sources, Portland Pozzolana / Ordinary Portland /Portland Slag Cement, Admixtures In Recommended Proportions As Per Is: 9103 To Accelerate / Retard Setting Of Concrete, To Improve Durability And Workability Without Impairing Strength; Including Pumping Of Concrete To Site Of Laying, Curing, Carriage For All Leads; But Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement As Per Direction Of The Engineer-In-Charge, For The Following Grades Of Concrete.: Note: Extra Cement Up To 10% Of The Minimum Specified Cement Content In Design Mix Shall Be Payable Separately. In Case The Cement Content In Design Mix Is More Than 110% Of The Specified Minimum Cement Content, The Contractor Shall Have Discretion To Either Re-Design The Mix Or Bear The Cost Of Extra Cement.All Works Upto Plinth Level Concrete Of M25 Grade With Minimum Cement Content Of 330 Kg /Cum , Providing And Laying In Position Ready Mixed Or Site Batched Design Mix Cement Concrete For Reinforced Cement Concrete Work; Using Coarse Aggregate And Fine Aggregate Derived From Natural Sources, Portland Pozzolana / Ordinary Portland /Portland Slag Cement, Admixtures In Recommended Proportions As Per Is: 9103 To Accelerate / Retard Setting Of Concrete, To Improve Durability And Workability Without Impairing Strength; Including Pumping Of Concrete To Site Of Laying, Curing, Carriage For All Leads; But Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement As Per Direction Of The Engineer-In-Charge, For The Following Grades Of Concrete.: Note: Extra Cement Up To 10% Of The Minimum Specified Cement Content In Design Mix Shall Be Payable Separately. In Case The Cement Content In Design Mix Is More Than 110% Of The Specified Minimum Cement Content, The Contractor Shall Have Discretion To Either Re-Design The Mix Or Bear The Cost Of Extra Cement.All Works Above Plinth Level Upto Floor V Level Concrete Of M25 Grade With Minimum Cement Content Of 330 Kg /Cum , Stone Work , Coursed Rubble Masonry (Second Sort) With Hard Stone In Foundation & Plinth With :Cement Mortar 1:6(1 Cement : 6 Coarse Sand) , Cladding Work , Providing Edge Moulding To 18Mm Thick Marble Stone Counters, Vanities Etc., Including Machine Polishing To Edge To Give Gloss Finish Etc. Complete As Per Design Approved By Engineer-In-Charge,Granite Work , Wood And P. V. C. Work , Providing Wood Work In Frames Of Doors, Windows, Clerestory Windows And Other Frames, Wrought Framed And Fixed In Position With Hold Fast Lugs Or With Dash Fasteners Of Required Dia & Length (Hold Fast Lugs Or Dash Fastener Shall Be Paid For Separately).Sal Wood , Providing And Fixing Isi Marked Flush Door Shutters Conforming To Is : 2202 (Part I) Decorative Type, Core Of Block Board Construction With Frame Of 1St Class Hard Wood And Well Matched Teak 3 Ply Veneering With Vertical Grains Or Cross Bands And Face Veneers On Both Faces Of Shutters.35 Mm Thick Including Isi Marked Stainless Steel Butt Hinges With Necessary Screws , Providing 40X5 Mm Flat Iron Hold Fast 400 Mm Long Including Fixing To Frame With 10 Mm Diameter Bolts, Nuts And Wooden Plugs And Embedding In Cement Concrete Block 300X100x150 Mm 1:3:6 Mix (1 Cement: 3 Coarse Sand : 6 Graded Stone Aggregate 20 Mm Nominal Size). , Providing And Fixing Bright Finished Brass 100 Mm Mortice Latch And Lock With 6 Levers And A Pair Of Lever Handles Of Approved Quality With Necessary Screws Etc. Complete. , Providing And Fixing Aluminium Extruded Section Body Tubular Type Universal Hydraulic Door Closer (Having Brand Logo With Isi, Is : 3564, Embossed On The Body, Door Weight Upto 36 Kg To 80 Kg And Door Width From 701 Mm To 1000 Mm), With Double Speed Adjustment With Necessary Accessories And Screws Etc. Complete. , Providing And Fixing Aluminium Hanging Floor Door Stopper, Isi Marked, Anodised (Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868) Transparent Or Dyed To Required Colour And Shade, With Necessary Screws Etc. Complete.Twin Rubber Stopper , Providing And Fixing Factory Made Upvc Glazed/Wire Mesh Windows/ Doors Comprising Of Lead Free Upvc Multi-Chambered Frame, Sash And Mullion/Coupler (Where Ever Required) Extruded Profiles Having Minimum Wall Thickness Of 1.70 Mm For Series R1 And R2 Profiles And 2.10 Mm For Series R3 And R4 Profiles Conforming To En: 12608 In Any Shape, Colour And Design Duly Reinforced With Galvanized Mild Steel Section Made Of Required Shape & Size As Per Cpwd Specification, Upvc Extruded Glazing Beads, Interlocks And Lnline Sash Adaptor (Where Ever Required) Of Appropriate Dimension, Epdm Gasket, Hardware, Ss 304 Grade Fasteners Of Minimum 8 Mm Dia With Countersunk Head, Comprising Of Matching Polyamide Pa6 Grade Sleeve For Fixing Frame To Finished Wall As Per Is 1367 : Part 1 To 14, Plastic Packers, Plastic Caps And Necessary Stainless Steel Screws Etc. Profile Of Frame, Sash & Mullion (If Required) Shall Be Mitred Cut And Fusion Welded/Mechanically Jointed Duly Sealed At All Corners, Including Drilling Of Holes For Fixing Hardware And Drainage Of Water Etc. After Fixing Frame The Gap Between Frame And Adjacent Finished Wall Shall Be Filled With Weather Proof Silicon Sealant Over Backer Rod Of Approved Size And Quality, All Complete As Per Approved Drawing Conforming To Cpwd Specification & Direction Of Engineer-In-Charge. Section Of Steel Reinforcement And Cross Sections Of Upvc Profiles To Be As Per Design Approved By Engineer-In-Charge. Wire Mesh / Glazing Of Plain/ Toughened/ Laminated/ Double Glass Unit With / Without High Performance Coatings As Per Design Requirements And Conforming To Is: 3548 & Is: 16231 Shall Be Paid Separately. Note:- Structural Design Proof Checked From A Government Engineering Institute, To Be Provided By The Manufacturer For (I) Sites With Basic Wind Speed 45 M/Sec As Per Is 875 - Part 3 (Ii) Sites With Structure Height More Than 20M For All Wind Speedscasement Window Double Panels With Fixed Mullion With S.S. 304 Friction Hinges As Per Size And Weight Of Sash, Multi-Point Locking System, Zinc Alloy (Zamak) Powder Coated Handles.Using R2 Series With Frame (39 Mm & Above) X (39 Mm & Above) & Sash (39 Mm & Above) X (60 Mm & Above) & Mullion (39 Mm & Above) X (60 Mm & Above). (Height Upto 1.2 Metre). , Steel Work , Steel Work In Built Up Tubular (Round, Square Or Rectangular Hollow Tubes Etc.) Trusses Etc., Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer, Including Welding And Bolted With Special Shaped Washers Etc. Complete.Hot Finished Welded Type Tubes , Steel Work Welded In Built Up Sections/ Framed Work, Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer Using Structural Steel Etc. As Required.In Gratings, Frames, Guard Bar, Ladder, Railings, Brackets, Gates And Similar Works , Flooring , Providing And Laying Vitrified Tiles In Floor In Diferent Sizes (Thickness To Be Specified By The Manufacturer) With Water Absorption Less Than 0.08% And Conforming To Is:15622, Of Approved Brand & Manufacturer, In All Colours And Shade, Laid On 20 Mm Thick Cement Mortar 1:4 (1 Cement: 4 Coarse Sand) Jointing With Grey Cement Slurry @3.3 Kg/Sqm Including Grouting The Joints With White Cement And Matching Pigments Etc. The Tiles Must Be Cut With The Zero Chipping Diamond Cutter Only . Laying Of Tiles Will Be Done With The Notch Trowel, Plier, Wedge, Clips Of Required Thickness, Leveling System And Rubber Mallet For Placing The Tiles Gently And Easily.Double Charge Vitrified Tile Polished Finish Of Size Of Tile 600 X 600 Mm , Providing And Laying Flamed Finish Granite Stone Flooring In Required Design And Patterns, In Linear As Well As Curvilinear Portions Of The Building All Complete As Per The Architectural Drawings With 18 Mm Thick Stone Slab Over 20 Mm (Average) Thick Base Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) Laid And Jointed With Cement Slurry And Pointing With White Cement Slurry Admixed With Pigment Of Matching Shade Including Rubbing, Curing And Polishing Etc. All Complete As Specified And As Directed By The Engineer-In-Charge :Flamed Finish Granite Stone Slab Jet Black, Cherry Red, Elite Brown, Cat Eye Or Equivalent. , Finishing , 20 Mm Cement Plaster Of Mix:1:4(1 Cement: 4 Fine Sand) , 20 Mm Cement Plaster Of Mix:1:4(1 Cement: 4 Coarse Sand) , 6 Mm Cement Plaster 1:3 (1 Cement: 3 Fine Sand) Finished With A Floating Coat Of Neat Cement And Thick Coat Of Lime Wash On Top Of Walls When Dry For Bearing Of Reinforced Cement Concrete Slabs And Beams. , Providing And Applying Plaster Of Paris Putty Of 2 Mm Thickness Over Plastered Surface To Prepare The Surface Even And Smooth Complete. , 12 Mm Thick Plain Cement Mortar Bands In Cement Mortar 1:4 (1 Cement: 4 Fine Sand):Moulded Band , Finishing Walls With Premium Acrylic Smooth Exterior Paint With Silicone Additives Of Required Shade:New Work (Two Or More Coats Applied @ 1.43 Itr/10 Sqm Over And Including Priming Coat Of Exterior Primer Applied @ 0.90 Litre/10 Sqm) , Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture To Give An Even Shade :Two Or More Coats On New Work , French Spirit Polishing :Two Or More Coats On New Works Including A Coat Of Wood Filler , Wall Painting With Acrylic Emulsion Paint, Having Voc (Volatile Organic Compound ) Content Less Than 50 Grams/ Litre, Of Approved Brand And Manufacture, Including Applying Additional Coats Wherever Required, To Achieve Even Shade And Colour.Two Coats , Applying Priming Coats With Primer Of Approved Brand And Manufacture, Having Low Voc (Volatile Organic Compound ) Content.With Water Thinnable Cement Primer On Wall Surface Having Voc Content Less Than 50 Grams/Litre , Dismantling And Demolishing , Demolishing Cement Concrete Manually/ By Mechanical Means Including Disposal Of Material Within 50 Metres Lead As Per Direction Of Engineer - In - Charge.Nominal Concrete 1:3:6 Or Richer Mix (Including Equivalent Design Mix) , Disposal Of Building Rubbish / Malba / Similar Unserviceable, Dismantled Or Waste Materials By Mechanical Means, Including Loading, Transporting, Unloading To Approved Municipal Dumping Ground Or As Approved By Engineer-In-Charge, Beyond 50 M Initial Lead, For All Leads Including All Lifts Involved. , Aluminium Work , Providing And Fixing Glazing In Aluminium Door, Window, Ventilator Shutters And Partitions Etc. With Epdm Rubber / Neoprene Gasket Etc. Complete As Per The Architectural Drawings And The Directions Of Engineer-In-Charge . (Cost Of Aluminium Snap Beading Shall Be Paid In Basic Item):With Float Glass Panes Of 5 Mm Thickness (Weight Not Less Than 12.50 Kg/Sqm) , Filling The Gap In Between Aluminium Frame & Adjacent Rcc/ Brick/ Stone Work By Providing Weather Silicon Sealant Over Backer Rod Of Approved Quality As Per Architectural Drawings And Direction Of Engineer-In-Charge Complete.Upto 5 Mm Depth And 5 Mm Width , Market Rate Items , Provinding Precast Cement Concrete Solid Block Masonry Including Hoisting And Setting In Position With Cement Mortar 1:6 (Cement :6 Coarse Sand) Completed As Per The Direction Of Engineer In Charge As Per Site Condition , Providing And Fixing 5 Mm Thick Clear Transparent Acrylic Sheet Of Approved Brand And Manufacture For Fixed Curved Portions In Openings, Including Epdm Rubber/Neoprene Gasket And All Necessary Accessories, Complete In All Respects As Per The Directions Of The Engineer-In-Charge. , Electrical Work , Laying And Fixing Of One No Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Upto 35 Sq.Mm (Clamped With 1Mm Thick Saddle) Size On Wall Surface As Required. , Supplying And Making End Termination With Brass Compression Gland And Aluminium Lugs For 4 X 16 Sq. Mm (25Mm) Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade As Required. , Supplying And Fixing Of 4 Way (4 + 12), Double Door Surface/ Recess Mounting, Vertical Type, 415 V, Tpn Mcb Distribution Board Of Sheet Steel, Dust Protected, Duly Powder Painted, Inclusive Of 200 A Tinned Copper Bus Bar, Common Neutral Link, Earth Bar, Din Bar For Mounting Mcbs As Required . , Supplying And Fixing 6 Way, Double Door, Single Pole And Neutral, Sheet Steel, Mcb Distribution Board, 240 V, On Surface / Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Including Earthing Etc. As Required. (But Without Mcb/Rccb/Isolator. , Supplying & Fixing 5A To 32 A Rating, 240/415V, 10Ka, C Curve, Miniature Circuit Breaker Suitable For Inductive Load For Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.Single Pole , Supplying & Fixing 5A To 32 A Rating, 240/415V, 10Ka, C Curve, Miniature Circuit Breaker Suitable For Inductive Load For Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.Single Pole And Neutral , Supplying & Fixing 5A To 32 A Rating, 240/415V, 10Ka, C Curve, Miniature Circuit Breaker Suitable For Inductive Load For Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.Triple Pole , Supplying & Fixing 5A To 32 A Rating, 240/415V, 10Ka, C Curve, Miniature Circuit Breaker Suitable For Inductive Load For Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.Triple Pole And Neutral , Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface/ Recessed Medium Class Pvc Conduit As Required.2 X 2.5 Sq. Mm + 1 X 2.5 Sq. Mm Earth Wire , Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface/ Recessed Medium Class Pvc Conduit As Required.2 X 4 Sq. Mm + 1 X 4 Sq. Mm Earth Wire , Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface/ Recessed Medium Class Pvc Conduit As Required.4 X 6 Sq. Mm + 2 X 6 Sq. Mm Earth Wire , Supplying And Fixing Following Size/ Modules, Gi Box Along With Modular Base & Cover Plate For Modular Switches In Recess Etc. As Required 2 Module (75Mmx75mm) , Supplying And Fixing Following Size/ Modules, Gi Box Along With Modular Base & Cover Plate For Modular Switches In Recess Etc. As Required 3 Module (100Mmx75mm) , Supplying And Fixing Following Size/ Modules, Gi Box Along With Modular Base & Cover Plate For Modular Switches In Recess Etc. As Required 6 Module (200Mmx125mm) , Supplying And Fixing Following Modular Switch / Socket /Regulator On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. 5/6 A Switch , Supplying And Fixing Following Modular Switch / Socket /Regulator On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. 15/16 A Switch , Supplying And Fixing Following Modular Switch / Socket /Regulator On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. 3 Pin 5/6 A Socket Outlet , Supplying And Fixing Following Modular Switch / Socket /Regulator On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. 6 Pin 15/16 A Socket Outlet , Supplying And Fixing Following Modular Switch / Socket /Regulator On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. Bell Push , 2M Stepped Type Electronic Fan Regulator , Wiring For Light Point/Fan Point/Exhaust Fan Point/Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Medium Class Pvc Conduit, With Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. , Wiring For Group Controlled (Looped) Light Point/ Fanpoint/ Exhaust Fan Point/ Call Bell Point (Without Independent Switch Etc.) With 1.5 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface/ Recessed Pvc Conduit,And Earthing The Point With 1.5 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. (Group-C) , Providing And Fixing 6 Swg Dia G.I Wire On Surface Or In Recess For Loop Earthing As Required. , Supplying, Installation, Testing & Commissioning Of Photo Electronic Smoke Detector With Builtin Led And Mounting Base Plate Suitable With Ms Junction Box For Operation On 12V / 24V Complete With All Connections Etc. As Required. , Supplying, Installation, Testing & Commissioning Of Manual Call Box Of Abs Type In Surface/Recess With Stainless Steel Chain & Hammer Assembly Complete With Glass And Push Button Etc. As Required. , Supplying & Laying Of 2 X 1.5 Sqmm Fire Alarm Armoured Cable, 600/1000V Rated With Annealed Copper Conductor Having Xlpe Insulation, Steel Wire Armouring & Frls Outer Sheath Complete As Required. , Supplying And Fixing Dp Sheet Steel Enclosure On Surface / Recess Along With Upto 32A, 240 V, C Curve Dp Mcb Complete With Connections, Testing And Commissioning Etc. As Required. , Supplying And Fixing 30 A, 415 V, Tpn Industrial Type Socket Outlet, With 4 Pole And Earth, Metal Enclosed Plug Top Alongwith 32 A C Curve, Tpmcb, In Sheet Steel Enclosure, On Surface Or In Recess, With Chained Metal Cover For The Socket Out Let And Complete With Connections, Testing And Commissioning Etc. As Required , Supplying And Fixing 20 A, 240 V, Spn Industrial Type Socket Outlet, With 2 Pole And Earth, Metal Enclosed Plug Top Alongwith 20 A C Curve, Spmcb, In Sheet Steel Enclosure, On Surface Or In Recess, With Chained Metal Cover For The Socket Out Let And Complete With Connections, Testing And Commissioning Etc. As Required , Supply, Installation, Testing And Commissioning Of 1200 Mm Sweep,Bee 5 Star Rated, Ceiling Fan With Brush Less Direct Current (Bldc) Motor, Class Of Insulation: B, 3 Nos. Blades, 30 Cm Long Down Rod, 2 Nos. Canopies, Shackle Kit, Safety Rope, Copper Winding, Power Factor Not Less Than 0.9, Service Value (Cmm/W) Minimum 6.85, Air Delivery Minimum 215 Cmm, 350 Rpm (Tolerance As Per Is : 374-2019), Thd Less Than 10%, Speed Control Compitable For Electronic Type Regulator And All Remaining Accessories Including Safety Pin,Nut Bolts, Washers, Temperature Rise=75 Degree C (Max.), Insulation Resistance More Than 2 Mega Ohm, Suitable For 230 V, 50 Hz, Single Phase Ac Supply, Earthing Etc. Including Fixing Fan Hook In Ceiling Complete As Required. , Supplying, Installation, Testing & Commissioning Of Panel Light 2X2 Ft.,40W Of Powder Coated Die Cast / Extruded Aluminium Body (Thickness ≥ 1.20 Mm) Body Material And Construction As Per Is : 10322 With Driver As Per The Requirement With Driver Efficiency 85%, Operating Voltage Ac 140 270 Volt, Freq 50/60 Hz, Operating Temp Range -15 Deg To 40 Deg Centigrade, Internal Surge Protection Of 2.5 Kv With Short & Open Circuit Protection, Thd 10% , P. F.≥0.95, Ip20, Cri 80, Ugr (Unified Glare Rating) 19, Flicker Free, (Flicker Should Be Below 5 %), Life Time (Led,Driver & Electrical Circuitry), Of Minimum 50000 Burning Hours With, 70% Of Initial Lumen Maintained Till Life Ends As Per Lm80 Extrapolation Ies Tm-21-11Report, Cct 5700°K (As Per Ansi Bin), Sdcm(Standard Deviation Color Matching) 3, Maximum Power Consumption Should Not More Than The Specified Rating And Fixture Shall Be Of Relevant Bis Standard And Trade Mark Certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen Printing On Housing. Complete In All Respect I/C Connections With 1.5 Sq Mm Frls, Pvc Insulated Copper Conductor Single Core Cable And Earthing Etc. As Required. System Lumen Efficacy ≥105 Lm/Watt Output . Lm79 & Lm80 Test Report From Nabl Lab For All Testing Required For Led Fixtures As Per Bis Shall Be Submitted. Shape Size And Cct Shall Be As Approved By Engineer-In-Charge As Per Requirement. , Supplying And Fixing Of 25Mm Size Of Medium Class Pvc Conduit Along With Accessories In Surface/Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. , Supplying And Drawing 1 Run Of Utp 4 Pair Cat 6 Lan Cable In The Existing Surface/ Recessed Steel/ Pvc Conduit As Required. , Supplying And Installing 150 Mm Width X 50 Mm Depth X 1.6 Mm Thickness Size Of Perforated Painted With Powder Coating M.S. Cable Trays With Perforation Not More Than 17.5%, In Convenient Sections, Joined With Connectors, Suspended/Surface Mount From The Ceiling With M.S. Suspenders Including Bolts & Nuts, Painting Suspenders Etc As Required. , Supplying And Installing 150 Mm Width X 50 Mm Depth X 1.6 Mm Thickness Size Of Perforated Painted With Powder Coating M.S. Cable Trays Bends With Perforation Not More Than 17.5%,, Joined With Connectors, Suspended From The Ceiling With M.S. Suspenders Including Bolts & Nuts, Painting Suspenders Etc As Required. , Supplying And Fixing Call Bell/ Buzzer Suitable For Single Phase, 230 V, Complete As Required. , Supplying And Fixing Fp Mcb Sheet Steel Enclosure With Din Rail On Surface / Recess Etc. As Required. , Supplying & Fixing Of 4Pole, 63 A Rating, 415V, 10Ka, C Curve, Miniature Circuit Breaker Suitable For Inductive Load In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. , Supply Of Following Core, Size And Conductor 1.1Kv Grade Xlpe Insulated, Pvc Sheathed, Armoured Ug Cable In One Length As Per Is : 7098 (Pt-1) 1988,4C X 16Sq.Mm, Aluminium , Supply Of Following Core, Size And Conductor 1.1Kv Grade Xlpe Insulated, Pvc Sheathed, Armoured Ug Cable In One Length As Per Is : 7098 (Pt-1) 1988,4C X 6Sq.Mm, Copper , Supply Of Following Core, Size And Conductor 1.1Kv Grade Xlpe Insulated, Pvc Sheathed, Armoured Ug Cable In One Length As Per Is : 7098 (Pt-1) 1988,3C X 4 Sq.Mm, Copper , Supply And Laying Of Un Armoured Copper Single Core 10 Sq.Mm Flexible Cable With Annealed Copper Conductor In Suitable Size Hdpe Pipe In Ground/ On Surface As Required. , Supplying And Making End Termination With Brass Compression Gland And Copper Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Copper Conductor Cable Of 1.1 Kv Grade As Required.4 X 6 Sq.Mm , Supplying And Making End Termination With Brass Compression Gland And Copper Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Copper Conductor Cable Of 1.1 Kv Grade As Required.3 X 4 Sq.Mm , Supply ,Installation, Testing And Commissioning Of 2 Tr/24000Btu Per Hour And Bee-5 Star Rated Wall Mounted Inverter Type Hi Wall Split Cooling Air Conditioner Having Wireless Remote Controller, Hermetically Sealed/Scroll/Rotary Compressor And Eco Friendly Refrigerant,Initial Charge Of Refrigerant,Condensor And Evaporator Coils Of Copper Material, Air Filter With Auto Swing & Auto Restart Features, Suitable For Operation On 230V, Single Phase, 50Hz, Ac Power Supply. The Indoor Unit Shall Be Fixed Rigidly On Wall Using Necessary Frame, The Outdoor Unit Shall Be Mounted On Wall Or Floor Using Suitable Powder Coated Ms Angle Frame As Required. Including Clamps, Bolts, Nuts,Vibrating Dampers, Laying Of 3 Meter Standard Length Of Copper Refrigerant Piping With 3 Meter Pvc Covering Pipe, 3 Meter Drain Piping, Wrapping Tape And Necessary Insulation ,Electrical Flexible Cable Connectivity Between Indoor And Outdoor Unit. Necessary Drilling Of Hole And Finishing The Same To Match For The Surrounding As Required. , Supplying And Fixing Of Frp Box 200Mmx140mmx95mm Size (Nominal Size) On Surface With Hinged Door With Suitable Grounding Copper Bar Link With Holes Fitted Inside The Box Etc. As Required. , Supplying And Fixing Of Dual Rj 45 / Io Outlet On Existing Modular Switch Plate. , Supply,Installation,Testing And Commissioning Of Maintenace Free Earth Pit Of Single Pipe Technology Copper Pipe Of 2000Mm Long (Min), Outer Dia 50 Mm, Wall Thickness 1.2Mm(Min), Filled With Highly Conducting Metallic Compounds With The Permanent Sealing At Both The Ends And Lead Terminal Of 50 X 10 Mm Size At The Top The Length Of The Electrode Shall Be 2000 Mm Excluding The Lead Terminal And The Length Of The Lead Terminal At The Top Shall Be Minimum 50Mm. To Ensure The Moisture Content And Electrical Conductivity, Resistance Lowering Grounding Minerals Shall Be Filled Around The Electrode Of (Min25 Kg) .Heavy Duty Weather Proof Plastic Earth Pit Chamber With Cover Of Dimension 300 Mm Dia (Top), 260 Mm Dia(Bottom) And 300 Mm (Height) Shall Be Used, Numbering Of Pit And Measured Value Written With Weather Proof Painting Or Stickering. As Required.
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 2
5.
Housing Urban and Rular Development #11432189 Price Bid
Tender for Demolishing Of Cement Concrete Manually & Disposal Of Material Within 50 Metres.Nominal Concrete 1:3:6 Or Richer Mix , Demolishing Of Reinforced Cement Concrete Work Manually Including Stacking Of Steel Bars & Disposal Of Material Within 50 Metres. , Dismantling Of Doors & Windows Frames & Chawkhats Of Area Blow 3 Sqm. , Dismantiling Of Roofing Including Ridges, Hips Valley And Gutters Etc. And Stacking Gs Sheet , Earth Work In Excavation By Mechanical Means By Hydraulicexcavator )/ Manual Means In Foundation Trenches Or Drains (Not Exceeding 1.5 M In Width Or10 Sqm On Plan Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soil As Directed, Within A Lead Of 50 M. , Excavating Trenches Of Required Width For Pipes, Cables, Etc Including Excavation For Sockets, And Dressing Of Sides, Ramming Of Bottoms, Depth Upto 1.5 M, Including Getting Out The Excavated Soil, And Then Returning The Soil As Required, In Layers Not Exceeding 20 Cm In Depth, Including Consolidating Each Deposited Layer By Ramming, Watering, Etc. And Disposing Of Surplus Excavated Soil As Directed, Within A Lead Of 50 M :Pipes, Cables Etc. Exceeding 80 Mm Dia. But Not Exceeding 300 Mm Dia. , Filling Available Excavated Earth (Excluding Rock) In Trenches, Plinth,Sides Of Foundations Etc. In Layers Not Exceeding 20 Cm In Depth, Consolidating Each Deposited Layer By Ramming And Watering, Lead Up To 50 M And Lift Upto 1.5M. , Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level :1:4:8 (1 Cement : 4 Coarse Sand (Zoneiii) : 8 Graded Stone Aggregate 40 Mm Nominal Size) , Providing And Laying In Position Specified Grade Of Reinforceed Cement Cocrete Excluding The Cost Of Centering, Shuttring, Finishing And Reinforcment - All Work Upto Plinth Level.1:1.5:3 (1 Cement : 1.5 Coarse Sand : 3 Graded Stone Aggregate 20Mm Nominal Size) , Reinforced Cement Concrete Work In Walls (Any Thickness),Including Attached Pilasters, Buttresses, Plinth And String Courses,Fillets, Columns, Pillars, Piers,Abutments, Posts And Struts Etc. Upto Floor Five Level Excluding Cost Of Centring,Shuttering, Finishing And Reinforcement.1:1.5:3 (1 Cement : 1.5 Coarse Sand : 3 Graded Stone Aggregate 20Mm Nominal Size) , Reinforced Cement Concrete Work In Beams, Suspended Floors, Roofs Having Slope Up To 15° Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Window Sills, Staircases And Spiral Stair Cases Up To Floor Five Level, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement, With 1:2:4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size). , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For :Foundations, Footings, Bases Of Columns, Etc. For Mass Concrete , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For :Suspended Floors, Roofs, Landings, Balconies And Access Platform , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For :Lintels, Beams, Plinth Beams, Girders, Bressumers And Cantilevers , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For :Columns, Pillars, Piers, Abutments, Posts And Struts , Steel Reinforcement For Reinforced Cement Concrete Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Upto Plinth Level- Thermo-Mechanically Treated Bars , Structural Steel Work Riveted, Bolted Or Welded In Built Up Sections, Trusses And Framed Work, Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer All Complete. , Brick Work With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 In Foundation And Plinth In Cement Mortar 1:6 (1 Cement : 6 Coarse Sand) , Brick Work With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 In Superstructure Above Plinth Level Up To Floor V Level In All Shapes And Sizes In :Cement Mortar 1:6 (1 Cement : 6 Coarse Sand) , Half Brick Masonry With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 In Superstructure Above Plinth Level Up To Floor V Level Cement Mortar 1 :4 (1 Cement :4 Coarse Sand) , Casement Cum Fixed Panel Window Having One Single Casement Panel & One Fixed Panel With S.S 304 Friction Hinges As Per Size And Weight Of Sash, Multi-Point Locking System, Zinc Alloy (Zamak) Powder Coated Handles Using R3 Series With Frame (55 Mm & Above ) X (45 Mm & Above) & Sash (55 Mm & Above) X (65 Mm & Above) & Mullion (55 Mm & Above) X (65 Mm & Above). (Height Upto 1.8 Metre; Each Openable Shutter Upto 0.8M Width) , Ventilator Casement Window Single Panel With Or Without Fixed Panel With S.S. 304 Friction Hinges As Per Size And Weight Of Sash, Single Point Locking Zinc Alloy (Zamak) Using R3 Series With Frame (55 Mm & Above) X (45 Mm & Above) & Sash /Mullion (55 Mm & Above) X (65 Mm & Above). (Height Above 1.2 Metre) , Casement Door Double Panel With French (False) Mullion With Zinc Alloy (Zamak) 30 Hinges, Multi-Point Locking System With Cylinder, Zinc Alloy (Zamak) Powder Coated Handles On Both Sides.Using R4 Series With Frame (64 Mm & Above) X (55 Mm & Above) & Sash (64 Mm & Above) X (100 Mm & Above) & French (False) Mullion (64 Mm & Above) X (60 Mm & Above). (Height Above 2.5 Metre). , Providing And Fixing 18 Mm Thick Gang Saw Cut, Mirror Polished, Premoulded And Prepolished, Machine Cut For Kitchen Platforms, Vanity Counters, Window Sills, Facias And Similar Locations Of Required Size, Approved Shade, Colour And Texture Laid Over 20 Mm Thick Base Cement Mortar 1 :4 (1 Cement: 4 Coarse Sand), Joints Treated With White Cement, Mixed With Matching Pigment, Epoxy Touch Ups, Including Rubbing, Curing, Moulding And Polishing Of Edges To Give High Gloss Finish Etc. Complete At All Levels Granite Stone Slab Of All Colour And Texture Except Black, Cherry/Ruby Red Area Of Slab Over 0.50 Sqm , Providing And Laying Vitrified Floor Tiles In Different Sizes (Thickness To Be Specified By The Manufacturer) With Water Absorption Less Than 0.08% And Conforming To Is : 15622, Of Approved Make, In All Colours And Shades, Laid On 20Mm Thick Cement Mortar 1:4 (1 Cement : 4 Coarse Sand), Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete. Size Of Tile 600X600 Mm , Providing And Fixing Ist Quality Ceramic Glazed Wall Tiles Conforming To Is: 15622 (Thickness To Be Specified By The Manufacturer), Of Approved Make, In All Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Engineer-In-Charge, In Skirting, Risers Of Steps And Dados, Over 12 Mm Thick Bed Of Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) And Jointing With Grey Cement Slurry @ 3.3Kg Per Sqm, Including Pointing In White Cement Mixed With Pigment Of Matching Shade Complete , Kota Stone Slabs 20 Mm Thick In Risers Of Steps, Skirting, Dado And Pillars Laid On 12 Mm (Average) Thick Cement Mortar 1 :3 (1 Cement: 3 Coarse Sand) And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slabs, Including Rubbing And Polishing Complete. , 12 Mm Cement Plaster Of Mix :1:6 (1 Cement: 6 Coarse Sand) , 20 Mm Cement Plaster Of Mix 1:6 (1 Cement: 6 Coarse Sand) , Providing & Applying White Cement Based Putty Of 2 Mm Thick Of Approved Brand Over Plastered Wall Surface For Even & Smooth Wall Fiinsh , Finishing With Delux Multi Surface Paint For Interiors Using Primer As Specified Two Or More Coats Applied On Wall At 1.25Ltr/10 Sqm Over And Including And On Coat Of Special Primer , Finishing Walls With Textured Acrylic Smooth Paint New Work (Two Or More Coats Applied @ 3.28 Ltr/ 10 Sqm Over And Including Priming Coat Of Exterior Primer Applied @ 2.20 Kg/ 10 Sqm , Applying Primer Coat With Ready Mix Red Oxide Zinc Chromate Primer Of Approved Brand And Manufacturer On Steel Works And Gi , Finishing With Epoxy Paint Two Coats On All Location Prepared And Applied On Steel , Providing Corrugated G.S. Sheet Roofing Including Vertical I Curved Surface Fixed With Polymer Coated J Or L Hooks, Bolts And Nuts 8 Mm Diameter With Bitumen And G.I. Limpet Washers Or With G.I. Limpet Washers Filled With White Lead, Including A Coat Of Approved Steel Primer And Two Coats Of Approved Paint On Overlapping Of Sheets Complete (Up To Any Pitch In Horizontal/ Vertical Or Curved Surfaces), Excluding The Cost Of Purlins, Rafters And Trusses And Including Cutting To Size And Shape Wherever Required. , Providing And Fixing Precoated Galvanised Steel Sheet Roofing Accessories Of Total Coated Thickness 0.50 Mm (Base Metal Of Minimum 0.45 Mm Thickness With Total Coating Thickness Of 0.05 Mm) With Zinc Coating 120 Gram Per Sqm As Per Is: 277, In 240 Mpa Steel Grade, 5-7 Microns Epoxy Primer On Both Side Of The Sheet And Polyester Top Coat 15-18 Microns Using Self Drilling/ Self Tapping Screws Complete : Ridges Plain (500 - 600Mm) , Providing And Fixing Precoated Galvanised Steel Sheet Roofing Accessories Of Total Coated Thickness 0.50 Mm (Base Metal Of Minimum 0.45 Mm Thickness With Total Coating Thickness Of 0.05 Mm) With Zinc Coating 120 Gram Per Sqm As Per Is: 277, In 240 Mpa Steel Grade, 5-7 Microns Epoxy Primer On Both Side Of The Sheet And Polyester Top Coat 15-18 Microns Using Self Drilling/ Self Tapping Screws Complete Barge Board Upto 300 Mm , Providing And Fixing Precoated Galvanised Steel Sheet Roofing Accessories Of Total Coated Thickness 0.50 Mm (Base Metal Of Minimum 0.45 Mm Thickness With Total Coating Thickness Of 0.05 Mm) With Zinc Coating 120 Gram Per Sqm As Per Is: 277, In 240 Mpa Steel Grade, 5-7 Microns Epoxy Primer On Both Side Of The Sheet And Polyester Top Coat 15-18 Microns Using Self Drilling/ Self Tapping Screws Complete Gutter 600 Mm Over All Girth , Providing 10 Mm Thick Plaster Of Paris (Gypsum Anhydrous) Ceiling Up To A Height Of 5 M Above Floor Level, Over First Class Kail Wood Strips 25X6 Mm With 10 Mm Gap In Between And Reinforced With Rabbit Wire Mesh Fixed To Wooden Frame (Frame Work To Be Paid Separately) , Random Rubble Masonry With Hard Stone In Foundation And Plinth Including Levelling Up With Cement Concrete 1:6:12 (1 Cement : 6 Coarse Sand : 12 Graded Stone Aggregate 20 Mm Nominal Size) Upto Plinth Level With :Cement Mortar 1:6 (1 Cement : 6 Coarse Sand) , Random Rubble Masonry With Hard Stone In Foundation And Plinth Including Levelling Up With Cement Concrete 1:6:12 (1 Cement : 6 Coarse Sand : 12 Graded Stone Aggregate 20 Mm Nominal Size) Upto Plinth Level With :Cement Mortar 1:6 (1 Cement : 6 Coarse Sand)
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 3
Uttarakhand View Result →
6.
Housing Urban and Rular Development #11432188 Price Bid
Tender for Demolishing Of Cement Concrete Manually & Disposal Of Material Within 50 Metres.Nominal Concrete 1:3:6 Or Richer Mix , Demolishing Of Reinforced Cement Concrete Work Manually Including Stacking Of Steel Bars & Disposal Of Material Within 50 Metres. , Dismantling Of Doors & Windows Frames & Chawkhats Of Area Blow 3 Sqm. , Dismantiling Of Roofing Including Ridges, Hips Valley And Gutters Etc. And Stacking Gs Sheet , Earth Work In Excavation By Mechanical Means By Hydraulicexcavator )/ Manual Means In Foundation Trenches Or Drains (Not Exceeding 1.5 M In Width Or10 Sqm On Plan Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soil As Directed, Within A Lead Of 50 M. , Excavating Trenches Of Required Width For Pipes, Cables, Etc Including Excavation For Sockets, And Dressing Of Sides, Ramming Of Bottoms, Depth Upto 1.5 M, Including Getting Out The Excavated Soil, And Then Returning The Soil As Required, In Layers Not Exceeding 20 Cm In Depth, Including Consolidating Each Deposited Layer By Ramming, Watering, Etc. And Disposing Of Surplus Excavated Soil As Directed, Within A Lead Of 50 M :Pipes, Cables Etc. Exceeding 80 Mm Dia. But Not Exceeding 300 Mm Dia. , Filling Available Excavated Earth (Excluding Rock) In Trenches, Plinth,Sides Of Foundations Etc. In Layers Not Exceeding 20 Cm In Depth, Consolidating Each Deposited Layer By Ramming And Watering, Lead Up To 50 M And Lift Upto 1.5M. , Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level :1:4:8 (1 Cement : 4 Coarse Sand (Zoneiii) : 8 Graded Stone Aggregate 40 Mm Nominal Size) , Providing And Laying In Position Specified Grade Of Reinforceed Cement Cocrete Excluding The Cost Of Centering, Shuttring, Finishing And Reinforcment - All Work Upto Plinth Level.1:1.5:3 (1 Cement : 1.5 Coarse Sand : 3 Graded Stone Aggregate 20Mm Nominal Size) , Reinforced Cement Concrete Work In Walls (Any Thickness),Including Attached Pilasters, Buttresses, Plinth And String Courses,Fillets, Columns, Pillars, Piers,Abutments, Posts And Struts Etc. Upto Floor Five Level Excluding Cost Of Centring,Shuttering, Finishing And Reinforcement.1:1.5:3 (1 Cement : 1.5 Coarse Sand : 3 Graded Stone Aggregate 20Mm Nominal Size) , Reinforced Cement Concrete Work In Beams, Suspended Floors, Roofs Having Slope Up To 15° Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Window Sills, Staircases And Spiral Stair Cases Up To Floor Five Level, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement, With 1:2:4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size). , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For :Foundations, Footings, Bases Of Columns, Etc. For Mass Concrete , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For :Suspended Floors, Roofs, Landings, Balconies And Access Platform , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For :Lintels, Beams, Plinth Beams, Girders, Bressumers And Cantilevers , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For :Columns, Pillars, Piers, Abutments, Posts And Struts , Steel Reinforcement For Reinforced Cement Concrete Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Upto Plinth Level- Thermo-Mechanically Treated Bars , Structural Steel Work Riveted, Bolted Or Welded In Built Up Sections, Trusses And Framed Work, Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer All Complete. , Brick Work With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 In Foundation And Plinth In Cement Mortar 1:6 (1 Cement : 6 Coarse Sand) , Brick Work With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 In Superstructure Above Plinth Level Up To Floor V Level In All Shapes And Sizes In :Cement Mortar 1:6 (1 Cement : 6 Coarse Sand) , Half Brick Masonry With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 In Superstructure Above Plinth Level Up To Floor V Level Cement Mortar 1 :4 (1 Cement :4 Coarse Sand) , Casement Cum Fixed Panel Window Having One Single Casement Panel & One Fixed Panel With S.S 304 Friction Hinges As Per Size And Weight Of Sash, Multi-Point Locking System, Zinc Alloy (Zamak) Powder Coated Handles Using R3 Series With Frame (55 Mm & Above ) X (45 Mm & Above) & Sash (55 Mm & Above) X (65 Mm & Above) & Mullion (55 Mm & Above) X (65 Mm & Above). (Height Upto 1.8 Metre; Each Openable Shutter Upto 0.8M Width) , Ventilator Casement Window Single Panel With Or Without Fixed Panel With S.S. 304 Friction Hinges As Per Size And Weight Of Sash, Single Point Locking Zinc Alloy (Zamak) Using R3 Series With Frame (55 Mm & Above) X (45 Mm & Above) & Sash /Mullion (55 Mm & Above) X (65 Mm & Above). (Height Above 1.2 Metre) , Casement Door Double Panel With French (False) Mullion With Zinc Alloy (Zamak) 30 Hinges, Multi-Point Locking System With Cylinder, Zinc Alloy (Zamak) Powder Coated Handles On Both Sides.Using R4 Series With Frame (64 Mm & Above) X (55 Mm & Above) & Sash (64 Mm & Above) X (100 Mm & Above) & French (False) Mullion (64 Mm & Above) X (60 Mm & Above). (Height Above 2.5 Metre). , Providing And Fixing 18 Mm Thick Gang Saw Cut, Mirror Polished, Premoulded And Prepolished, Machine Cut For Kitchen Platforms, Vanity Counters, Window Sills, Facias And Similar Locations Of Required Size, Approved Shade, Colour And Texture Laid Over 20 Mm Thick Base Cement Mortar 1 :4 (1 Cement: 4 Coarse Sand), Joints Treated With White Cement, Mixed With Matching Pigment, Epoxy Touch Ups, Including Rubbing, Curing, Moulding And Polishing Of Edges To Give High Gloss Finish Etc. Complete At All Levels Granite Stone Slab Of All Colour And Texture Except Black, Cherry/Ruby Red Area Of Slab Over 0.50 Sqm , Providing And Laying Vitrified Floor Tiles In Different Sizes (Thickness To Be Specified By The Manufacturer) With Water Absorption Less Than 0.08% And Conforming To Is : 15622, Of Approved Make, In All Colours And Shades, Laid On 20Mm Thick Cement Mortar 1:4 (1 Cement : 4 Coarse Sand), Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete. Size Of Tile 600X600 Mm , Providing And Fixing Ist Quality Ceramic Glazed Wall Tiles Conforming To Is: 15622 (Thickness To Be Specified By The Manufacturer), Of Approved Make, In All Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Engineer-In-Charge, In Skirting, Risers Of Steps And Dados, Over 12 Mm Thick Bed Of Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) And Jointing With Grey Cement Slurry @ 3.3Kg Per Sqm, Including Pointing In White Cement Mixed With Pigment Of Matching Shade Complete , Kota Stone Slabs 20 Mm Thick In Risers Of Steps, Skirting, Dado And Pillars Laid On 12 Mm (Average) Thick Cement Mortar 1 :3 (1 Cement: 3 Coarse Sand) And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slabs, Including Rubbing And Polishing Complete. , 12 Mm Cement Plaster Of Mix :1:6 (1 Cement: 6 Coarse Sand) , 20 Mm Cement Plaster Of Mix 1:6 (1 Cement: 6 Coarse Sand) , Providing & Applying White Cement Based Putty Of 2 Mm Thick Of Approved Brand Over Plastered Wall Surface For Even & Smooth Wall Fiinsh , Finishing With Delux Multi Surface Paint For Interiors Using Primer As Specified Two Or More Coats Applied On Wall At 1.25Ltr/10 Sqm Over And Including And On Coat Of Special Primer , Finishing Walls With Textured Acrylic Smooth Paint New Work (Two Or More Coats Applied @ 3.28 Ltr/ 10 Sqm Over And Including Priming Coat Of Exterior Primer Applied @ 2.20 Kg/ 10 Sqm , Applying Primer Coat With Ready Mix Red Oxide Zinc Chromate Primer Of Approved Brand And Manufacturer On Steel Works And Gi , Finishing With Epoxy Paint Two Coats On All Location Prepared And Applied On Steel , Providing Corrugated G.S. Sheet Roofing Including Vertical I Curved Surface Fixed With Polymer Coated J Or L Hooks, Bolts And Nuts 8 Mm Diameter With Bitumen And G.I. Limpet Washers Or With G.I. Limpet Washers Filled With White Lead, Including A Coat Of Approved Steel Primer And Two Coats Of Approved Paint On Overlapping Of Sheets Complete (Up To Any Pitch In Horizontal/ Vertical Or Curved Surfaces), Excluding The Cost Of Purlins, Rafters And Trusses And Including Cutting To Size And Shape Wherever Required. , Providing And Fixing Precoated Galvanised Steel Sheet Roofing Accessories Of Total Coated Thickness 0.50 Mm (Base Metal Of Minimum 0.45 Mm Thickness With Total Coating Thickness Of 0.05 Mm) With Zinc Coating 120 Gram Per Sqm As Per Is: 277, In 240 Mpa Steel Grade, 5-7 Microns Epoxy Primer On Both Side Of The Sheet And Polyester Top Coat 15-18 Microns Using Self Drilling/ Self Tapping Screws Complete : Ridges Plain (500 - 600Mm) , Providing And Fixing Precoated Galvanised Steel Sheet Roofing Accessories Of Total Coated Thickness 0.50 Mm (Base Metal Of Minimum 0.45 Mm Thickness With Total Coating Thickness Of 0.05 Mm) With Zinc Coating 120 Gram Per Sqm As Per Is: 277, In 240 Mpa Steel Grade, 5-7 Microns Epoxy Primer On Both Side Of The Sheet And Polyester Top Coat 15-18 Microns Using Self Drilling/ Self Tapping Screws Complete Barge Board Upto 300 Mm , Providing And Fixing Precoated Galvanised Steel Sheet Roofing Accessories Of Total Coated Thickness 0.50 Mm (Base Metal Of Minimum 0.45 Mm Thickness With Total Coating Thickness Of 0.05 Mm) With Zinc Coating 120 Gram Per Sqm As Per Is: 277, In 240 Mpa Steel Grade, 5-7 Microns Epoxy Primer On Both Side Of The Sheet And Polyester Top Coat 15-18 Microns Using Self Drilling/ Self Tapping Screws Complete Gutter 600 Mm Over All Girth , Providing 10 Mm Thick Plaster Of Paris (Gypsum Anhydrous) Ceiling Up To A Height Of 5 M Above Floor Level, Over First Class Kail Wood Strips 25X6 Mm With 10 Mm Gap In Between And Reinforced With Rabbit Wire Mesh Fixed To Wooden Frame (Frame Work To Be Paid Separately) , Excavation Work By Mechanical Means (Hydraulic Excavator)/ Manual Means In Foundation Trenches Or Drains (Not Exceeding 1.5M In Width Or 10 Sqm On Plan), Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soils As Directed, Within A Lead Of 50 M. , Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level :1 :1.5 :3 (1 Cement: 1 % Coarse Sand (Zone-Ill) Derived From Natural Sources : 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources) , Supply & Fixing Of Pedestrain Traffic Barrier , Supply & Fixing Of Dustbin , Supply & Fixing Of Signages
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 3
Uttarakhand View Result →
7.
Housing Urban and Rular Development #11432187 Price Bid
Tender for Demolishing Of Cement Concrete Manually & Disposal Of Material Within 50 Metres.Nominal Concrete 1:3:6 Or Richer Mix , Demolishing Of Reinforced Cement Concrete Work Manually Including Stacking Of Steel Bars & Disposal Of Material Within 50 Metres. , Demolishing Of Brick Work Manually. In Cement Mortar Disposal Of Material Within 50 Metres , Demolishing Stone Rubble Masonry Manually/ By Mechanical Means Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Metres Lead As Per Direction Of Engineer-In-Charge. In Cement Mortar , Dismantling Of Doors & Windows Frames & Chawkhats Of Area Blow 3 Sqm. , Dismantiling Of Roofing Including Ridges, Hips Valley And Gutters Etc. And Stacking Gs Sheet , Earth Work In Surface Excavation Not Exceeding 30 Cm In Depth But Exceeding 1.5 M In Width As Well As 10 Sqm On Plan Including Getting Out And Disposal Of Excavated Earth Upto 50 M And Lift Upto 1.5 M, As Directed By Engineer-In- Charge: , Earth Work In Excavation By Mechanical Means By Hydraulicexcavator )/ Manual Means In Foundation Trenches Or Drains (Not Exceeding 1.5 M In Width Or10 Sqm On Plan Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soil As Directed, Within A Lead Of 50 M. , Filling Available Excavated Earth (Excluding Rock) In Trenches, Plinth,Sides Of Foundations Etc. In Layers Not Exceeding 20 Cm In Depth, Consolidating Each Deposited Layer By Ramming And Watering, Lead Up To 50 M And Lift Upto 1.5M. , Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level 1:2:4 (1 Cement : 2 Coarse Sand: 4 Graded Stone Aggregate 40 Mm Nominal Size) , Providing And Laying Cement Concrete In Retaining Walls, Return Walls, Walls (Any Thickness) Including Attached Pilasters, Columns, Piers, Abutments, Pillars, Posts, Struts, Buttresses, String Or Lacing Courses, Parapets, Coping, Bed Blocks, Anchor Blocks, Plain Window Sills, Fillets, Sunken Floor Etc., Up To Floor Five Level, Excluding The Cost Of Centering, Shuttering And Finishing: 1:2:4 , Providing And Laying Cement Concrete In Kerbs, Steps And The Like At Or Near Ground Level Excluding The Cost Of Centering, Shuttering And Finishing. 1:1.5:3 (1 Cement: 1.5 Coarse Sand : 3 Graded Stone Aggregate 20 Mm Nominal Size) , Making Plinth Protection 50 Mm Thick Of Cement Concrete 1:3:6 (1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20 Mm Nominal Size) Over 75 Mm Thick Bed Of Dry Brick Ballast 40 Mm Nominal Size. , Providing And Laying In Position Ready Mixed Or Site Batched Design Mix Cement Concrete For Reinforced Cement Concrete Work Using Coarse Aggregate And Fine Aggregate Derived From Natural Sources, Portland Pozzolana / Ordinary Portland /Portland Slag Cement, Admixtures In Recommended Proportions To Accelerate / Retard Setting Of Concrete, To Improve Durability And Workability Without Impairing Strength Including Pumping Of Concrete To Site Of Laying, Curing, Carriage For All Leads But Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement As Per Direction Of The Engineer-In-Charge, For The Following Grades Of Concrete. , Reinforced Cement Concrete Work In Walls, Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc. Above Plinth Level Up To Floor Five Level, Excluding Cost Of Centering, Shuttering, Finishing And Reinforcement. 1:1.5:3 (1 Cement :1.5 Coarse Sand: 3 Graded Stone Aggregate 20 Mm Nominal Size) , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For :Foundations, Footings, Bases Of Columns, Etc. For Mass Concrete , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For :Walls Including Attached Pilasters, Butteresses, Plinth And String Courses Etc. , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For :Lintels, Beams, Plinth Beams, Girders, Bressumers And Cantilevers , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For :Suspended Floors, Roofs, Landings, Balconies And Access Platform , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For :Columns, Pillars, Piers, Abutments, Posts And Struts , Steel Reinforcement For Reinforced Cement Concrete Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Upto Plinth Level- Thermo-Mechanically Treated Bars , Structural Steel Work Riveted, Bolted Or Welded In Built Up Sections, Trusses And Framed Work, Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer All Complete. , Brick Work With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 In Foundation And Plinth In Cement Mortar 1:6 (1 Cement : 6 Coarse Sand) , Brick Work With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 In Superstructure Above Plinth Level Up To Floor V Level In All Shapes And Sizes In :Cement Mortar 1:6 (1 Cement : 6 Coarse Sand) , Half Brick Masonry With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 In Superstructure Above Plinth Level Up To Floor V Level Cement Mortar 1 :4 (1 Cement :4 Coarse Sand) , Three Track Three Panels Sliding Window With Aluminium Channel For Roller Track, Wool Pile, Nylon Rollers With Ss 304 Body. Using R3 Series With Frame (98 Mm & Above) X (40 Mm & Above) & Sash (30 Mm & Above) X (55 Mm & Above) With Zinc Alloy (Zamak) Powder Coated Handle On Two End Panels Along With Multi-Point Locking System (Height Upto 1.8 Metre) , Casement Door Double Panel With French (False) Mullion With Zinc Alloy (Zamak) 30 Hinges, Multi-Point Locking System With Cylinder, Zinc Alloy (Zamak) Powder Coated Handles On Both Sides.Using R4 Series With Frame (64 Mm & Above) X (55 Mm & Above) & Sash (64 Mm & Above) X (100 Mm & Above) & French (False) Mullion (64 Mm & Above) X (60 Mm & Above). (Height Above 2.5 Metre). , Providing And Laying Vitrified Floor Tiles In Different Sizes (Thickness To Be Specified By The Manufacturer) With Water Absorption Less Than 0.08% And Conforming To Is : 15622, Of Approved Make, In All Colours And Shades, Laid On 20Mm Thick Cement Mortar 1:4 (1 Cement : 4 Coarse Sand), Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete. Size Of Tile 600X600 Mm , Providing And Laying Vitrified Floor Tiles In Different Sizes (Thickness To Be Specified By The Manufacturer) With Water Absorption Less Than 0.08% And Conforming To Is : 15622, Of Approved Make, In All Colours And Shades, Laid On 20Mm Thick Cement Mortar 1:4 (1 Cement : 4 Coarse Sand), Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete. Size Of Tile 600X600 Mm , Providing And Fixing Ist Quality Ceramic Glazed Wall Tiles Conforming To Is: 15622 (Thickness To Be Specified By The Manufacturer), Of Approved Make, In All Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Engineer-In-Charge, In Skirting, Risers Of Steps And Dados, Over 12 Mm Thick Bed Of Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) And Jointing With Grey Cement Slurry @ 3.3Kg Per Sqm, Including Pointing In White Cement Mixed With Pigment Of Matching Shade Complete , Providing And Laying 60 Mm Thick Faciory Made Cement Concrete Interlocking Paver Block Of M-30 Grade Made By Block Making Machine With Strong Vibratory Compaction, Of Approved Size, Design & Shape, Laid In Required Colour And Pattern Over And Including 50 Mm Thick Compacted Bed Of Coarse Sand, Filling The Joints With Line Sand Etc. All Complete As Per The Direction Of Engineer-In-Charge. , Kota Stone Slabs 20 Mm Thick In Risers Of Steps, Skirting, Dado And Pillars Laid On 12 Mm (Average) Thick Cement Mortar 1 :3 (1 Cement: 3 Coarse Sand) And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slabs, Including Rubbing And Polishing Complete. , 12 Mm Cement Plaster Of Mix :1:6 (1 Cement: 6 Coarse Sand) , 20 Mm Cement Plaster Of Mix 1:6 (1 Cement: 6 Coarse Sand) , Providing & Applying White Cement Based Putty Of 2 Mm Thick Of Approved Brand Over Plastered Wall Surface For Even & Smooth Wall Fiinsh , Colour Washing Such As Green, Blue Or Buff To Give An Even Shade. New Work (Two Or More Coats) With A Base Coat Of Whiting. , Distempering With 1St Quality Acrylic Distemper Having Voc Content Less Than 50 Gram/Litre, Of Approved Manufacturer And Of Required Shade And Colour All Complete To Achieve Even Shade And Colour. New Work Over And Including Water Thinnable Priming Coat With Cement Primer Having Voc Content Less Than 50 Gram/Litre , Finishing Walls With Water Proofing Cement Paint Of Required Shade Two Or More Coats Applied. , Finishing With Delux Multi Surface Paint For Interiors Using Primer As Specified Two Or More Coats Applied On Wall At 1.25Ltr/10 Sqm Over And Including And On Coat Of Special Primer , Applying Primer Coat With Ready Mix Red Oxide Zinc Chromate Primer Of Approved Brand And Manufacturer On Steel Works And Gi , Finishing With Epoxy Paint Two Coats On All Location Prepared And Applied On Steel , Providing And Fixing Dry Cladding Upto 10 Metre Height With 30 Mm Thick Gang Saw Cut Stone With Machine Cut Edges Of Uniform Colour And Size Upto 1Mx1m, Fixed To Structural Steel Frame Work And/ Or With The Help Of Cramps, Pins Etc. And Sealing The Joints With Approved Weather Sealant As Per Architectural Drawing And Direction Of Engineer-In-Charge , Providing And Fixing Insulating Board Ceiling Of Approved Quality With Necessary Nails Etc. Complete. Flame Retardant Face Insulating Board, 12 Mm Thick , Providing And Fixing Thermal Insulation With Resin Bonded Fibre Glass Wool Conforming To Is: 8183. Density 16 Kg/M³, 50 Mm Thick, Wrapped In 200G Virgin Polythene Bags Placed Over Existing False Ceiling And Held In Position By Criss-Crossing Gi Wire , Providing Wood Work In Frames Of False Ceiling, Partitions Etc. Sawn And Fixed In Position With Necessary Stainless Steel Screws Etc. , Providing And Fixing 35 Mm Thick Factory Made Laminated Veneer Lumber Door Shutter Conforming To Is : 14616 And Tads 15:2001 (Part B), Fixing With Butt Hinges Of Required Size With Necessary Screws, All Complete As Per Directions Of Engineer- In-Charge And Panelling With Panels Of 12 Mm Thick Plain Grade -1, Medium Density Flat Pressed Three Layer Particle Board , Providing And Fixing Panelling Or Panelling And Glazing In Panelled Or Panelled And Glazed Shutters For Doors, Windows And Clerestory Windows. Panelling For Panelled Or Panelled And Glazed Shutters 25 Mm To 40 Mm Thick. Particle Board 12 Mm Thick. , Varnishing With Varnish Of Approved Brand And Manufacture : Two Or More Coats On New Work Over An Under Coat Of Suitable Shade With Ordinary Paint Of Approved Brand And Manufacture. Two Or More Coats Of Glue Sizing With Copal Varnish Over An Under Coat Of Flatting Varnish , French Spirit Polishing Two Or More Coats On New Works Including A Coat Of Wood Filler , Polishing On Wood Work With Ready Mixed Wax Polish Of Approved Brand And Manufacture :
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 3
Uttarakhand View Result →
8.
Housing Urban and Rular Development #11415087 Technical Bid
Tender for (I) Designing, P And F, Commissioning And Testing Of Vacuum- Operated Automatic Switchover Gas Chlorination System With 1 Working Chlorinator Plus 1 Standby Chlorinator Compatible With The Existing Gas Chlorination System With Three Months Trial Run And One Year Defect Liability Period. (Ii) Designing, P And F, Commissioning And Testing Of Chlorine Gas Dry Scrubber Consisting Of Support Structures, Ductwork Of Scrubber, Blower, Dry Scrubbing Tank, Dry Scrubbing Media, Necessary Piping, Motors, Controls, Exhaust Stack And Essential Accessories With Three Months Trial Run And One Year Defect Liability Period. Pandf Of Prefab Porta Cabin Of Size 1.83 M. X 1.83 M. And Height 2.3 M. With One Side Slope Design With 50 Mm Puf Wall Panels With Pre Painted Galvanized Sheet And 20/60 Mm Corrugated Puf Roof Panels With Pre Painted Galvanized Sheet With Door, Windows Etc. Complete In All Respect. (Iii) Designing, Pand F, Commissioning And Testing Of Auto-Shut Off Valve With Three Months Trial Run And One Year Defect Liability Period. (Iv) P And F Of Dual Gas Cylinder Duly Certified And Approved By Bis And By Explosive Department Of Govt. Of India, Nagpur Of 100 Kg Capacity Cylinder As Per Is 3196 Part -Iv. (V) Providing, Fixing, Installation, Commissioning And Testing Of Chlorine Leak Detector With Alarm/Hooter. (As Per Technical Specifications Of Gaseous Chlorination System As Per Letter Of Eic, Phed, Pkl. Memo No. 23070-23142-Phe/Mont. Dated 28/02/2024 (Copy Attached). , Ht. Alluminium Cable: Supply Erection Testing Of Standard Make Xlpe 3 Core Ht / 11 Kv Grade Isi Marked Stranded Compact Circular Aluminium Conductor, Conductor Screen With Extruded Semi Conducting Compound, Xlpe Insulated, Insulation Screening With Extruded Semi Conducting Compound In Combination With Copper Tape, Cores Laid Up, Innersheath Of Pvc, Galvanised Steel Flat Strip Armoured, And Overall Pvc Sheathed Cable Conforming To Is 7098 (Part-2) 2011 With Up To Date Amendments For Making Following Connection A) From G.O Switch To Metering Equipment . B) From Metering Equipment To Transformer Complete In All Respect. Make: Indian Cables Ltd./ Polycab / repair renovation Cables / Finolex / Havells Cables. 35 Sqmm Size , Ht Metering Panel: Supply Indoor Type 11Kv Vcb Control Cubical Panel With Vertical Isolation Type Breaker As Per Relevant Is As Amended Up To Date And Additional Specifications, Having Capacities As Mentioned Below, Single Break Trip Free Mechanism, Manually Charged And Auto/Manually Closing Breaker Suitable For Use On 11Kv, 3 Phase 50Hz Ac, Supply With Short Circuit Fault Level Of 500 Amps Capacity, Breaker Featured With Local On/Off Indicator With Hand Trip Device, Spring Release Coil, Shunt Trip Coil And Auxiliary Switch Of 2No Plus 2Nc And Equipped With Following Switchgears And Accessories Including Making Suitable Structure Arrangement For Installation, Control Wiring And Connections Etc. As Reqd. (1 Ic Plus 2 Og) A). Vcb, 11Kv, 630Amp, 50Ka. B). 1Ph 11Kv/110 Volts Pt (Indoor Type) Class 0.2 Accuracy And 100 Va Burden -3 NoS. C). 33Kv Indoor Dead Type Dual Core Dual Ratio 3Cts Of Ratio 200-100/5-5 A Of 15 Va Burden, Ps 5 P10 And Accuracy Class 0.2. D). Control Panel- Cubicle Type Control Panel Suitable For Floor Mounting Made Out Of 1.63 Mm Cr Sheet Duly Powder Coated And With Following Relays. E). Microprocessor Based Numerical Relay For O/L, E/F And Sc Protection Suitable For Above. F). Master Trip Relay -2 NoS. G). Indicator Type Annunciator Panel With Buzzer. H). Digital Volt Meter- 0-11 Kv. I). Digital annual periodical maintenance Meter- 0-100 Amp. J). Ryb/ Trip/Closing/Spring Charged Indicator Lamp. K). Fault Annunciator Panel For O/L, Wti, Oti And Buchhloz Relay Alarm And Trip Auxiliary Relay. L). Tnc Switch For Operation. M). Multifunction Meter Em6400ng. N). Tcs Relay For Safe , Providing, Fixing, Lointing, Testing Of Mechanical Joints Complete With Rubber Gaskit, Galvanized Nuts And Bolts Including Labor, Tranportaion Ets Up To The Site. 300 Mm Nominal Diameter , Copper Cable: Supply, Erection, Testing And Commissioning Of Is Marked 3 Core Copper Cables, Solid Copper Conductor Up To 6Sqmm And Balance Stranded Copper, Xlpe Insulated, Cores Laid Up, Pvc Inner Sheathed, Armoured (Glavanised Wire For Cables Up To 10X1.5Sqmm, 8X2.5Sqmm, 2X10sqmm, 3X10sqmm, 4X6sqmm And Balance All Galvanized Steel Strip), Extruded Pvc Type St2 Outer Sheathed, /1100 V Grade As Per Is 7098 (Part 1) 1988 With Up To Date Amendments Along With All Accessories Like Thimble Lugs Etc For Motors As Per Entire Satisfaction Of Engineer-In Charge Complete In All Respect. Make:Finolex / Havells / repair renovation Cables. (150 Sqmm Size) , -Design, Supply, Installation And Testing Of Vfd Along With Distribution Panel In Enclosure For Motor Rating Of 105 Hp. Enclosure Shall Be Ip54. The Panel Shall Be Equipped With Mccb Tp With Suitable Rating, Spreader Link Tp, Extended Rotary Handle, Volt Meter Digital, Volt Selector Switch, annual periodical maintenance Meter, annual periodical maintenance Selector Switch, C.T With Suitable Rating, Control Mcb Sp With Suitable Rating, Pla Relay, Pushbutton Red Plus Green With Element, Indicator On/Off, Aluminium Bus Bar/Suitable Rating Power And Control Wiring Labour And Margin, Fabrication With Minimum Sheet Thickness Of 2 Mm For Load Bearing And Non-Load Bearing Side. Vfd Should Be Capable Of Protecting Motor From High And Low Voltage And Earth Fault As Well. Vfd Should Restrict Harmonics Up To 35% Vfd Should Be Capable Of Providing Starting Torque Up To 200% While Starting Motor. It Should Have Class 3C3 (Avg)Conformal Coating So That Components Are Safe From Dust And Moisture. Communication -Built-In Rs485 Modbus Rtu, Ambient Temperature -Heavy Duty: -10 ~ 50 Deg C Normal Duty: -10 ~ 40 Deg C, Pcb Protection Conformal Coating Complying To Iec 60721-3-3 Class 3C3, Application Humidity Below Relative Humidity 95% Rh (No Condensation) Altitude 0 To 1,000 M Without Deration 1,001 To 4,000 M With Deration Of 1% Per Rise In 100 M, Vibration Up To 9.8 M/Sec2 (1.0 G), Global Compliance Ce, Ul, Rohs, Control Method V/F Control, Sensorless Vector Control, Slip Compensation, Closed Loop Vector Control. Starting Torque 200% At 0.5Hz In Sensorless Vector Control And 150% At 3Hz In V/F, Frequency Control Range 0 To 400Hz In V/F, 0 To 300Hz In Sensorless 1, 0 To 120Hz In Sensorless 2 / Vector, Frequency Precision Setting- Digital: 0.01Hz, Analog: 0.03Hz (60Hz Base). Complete With All Other Accessories As Required. (At Mbs Near Yamuna River) , Ns Item -Lt Cable Alluminium: Supply, Erection, Testing And Commissioning Of Is Marked 3.5 Core Cables, Solid Aluminum Conductor Up To 10Sqmm And Balance Stranded Conductor, Xlpe Insulated, Cores Laid Up, Pvc Inner Sheathed, Armoured (Aluminium Wire For Single Core Up To 70Sqmm And Balance Aluminium Strip, Glavanised Wire For Cables Up To2x10sqmm, 3X10sqmm, 4X6sqmm And Balance All Galvanized Steel Strip) Extruded Pvc Type St2 Outer Sheathed, 650/1100V Grade As Per Is7098 (Part-1) 1988 With Up To Date Amendments Along With All Accessories Complete In All Respect. Make: Finolex / Havells / repair renovation Cables. (300 Sqmm Size). , -Cloud Based Software Comprising Of Middleware, Database And Front-End Web Interface Through Suitable Dashboards, Aggregation Screens And Gis Assisted Drill-Down From Macro To Micro To Be Provided. Application Data Hosting And Maintenance For Five Years Included In Scope. Cloud Servicesof Ministry Of Electronics And Information Technology (Meity), Government Of India Empaneled Cloud Service Providers Shall Be Taken Like Microsoft, Amazon, Google, Bsnl Etc. Cloud Service Provider Must Adhere The Security Standards And Guidelines Issued By Meity From Time-To-Time. As The Data Belongs To The State Government Of Haryana, Therefore The Application And Data Hosted On Cloud Must Be Kept And Stored In Data Centres Located In India Only. Any Change In Application Requirement Or Infrastructure Shall Be Borne By The Implementation Agency. Implementation Agency Shall Carry Out The Application Security Audit From A Certified Auditor (Ca). Application And Data Shall Be Kept Confidential And Only The Authorized Users Shall Have The Access To It. Implementation Agency Shall Be Responsible For Any Data Theft Or Data Leakages. , Ns Item -Online Chlorine Sensor : Supply, Installation, Testing, Commissioning With Five Year Maintenance Of Online Chlorine Sensor. (For Mbs) , Ns Item -Rtu: Functional Integration At Rtu-Cum-Gateway For Motorized Control Valve In Pump Control Panel (For Mbs) , Ns Item -Electromagnetic Flowmeter: Supply, Installation, Testing, Commissioning Five Year Maintenance, Electromagnetic Flowmeter Along With Its Installation Complete In All Respect As Per Specifications. Size As Per Site Requirement.(Ip-68), Rs-485 Modbus. Line Size 400 Mm, Installed At Pump End / Source. (For Mbs) , Ns Item -Automation Panel: Automation Panel For Integration With Vfd With Pump Control Panel, Along With Auto/Manual Selection Switch As Well As On/Off Push Button To Be Provided. Manual Selection Between Pump 1 And Pump 2 Depending On Which To Be Operated And Which To Be Stand By To Be Provided, Along With All Relay Interlocks And Provision Of Operation Of Pumps Through Potential Free/Open Collector Digital Outputs Of Rtu-Cum-Gateway Device. The Panel Will Contain Rtu-Cum-Gateway With Necessary I/Os And Edge Controller Motorized Control Valve In Local / Remote Or Auto/ Manual Modes Of Operation In Tandem With Cloud Scheduler Or Level Sensor-Based Functions. Panel Will Contain Smps With Rechargeable Battery Backup (Min. 24 Hrs.) Along With Facility To Connect All Field Instruments With 24 Vdc Power Supply. (For Mbs , Ns Item -Radar And Water Level Transmitter: Supply, Installation, Testing, Commissioning With Five Year Maintenance Of Radar And Water Level Transmitter Alongwith According To Water Level In Ohsr (For Ohsr) Ingress Protection - Ip 66, Measuring Range - Up To 20 M, Process Temp.- -40 To 60 Deg. C, Full Pvdf Body - For A Long Sensor Lifetime. **Unit Rate Given, Actual Quantity To Be Ascertained While Placing Order. (For Mbs) , Ns Item -Sim Card: Sim Cards For Five Year Maintenance Of All The Instrument Above As Required. ( For Mbs) , Ns Item -Butterfly Valve: Supply, Installation, Testing, Commissioning With Five Year Maintenance Of Butterfly Valve With Electrical Actuator Body Material - Ci/Dipressure Rating - Pn16 Feedback - 100% Open And 100% Close. **Unit Rate Given, Actual Quantity To Be Ascertained While Placing Order 400 Mm , Designing, Supply And Erection Of Dg Set Of Capacity Given Below With Noise Controlled Devices Acoustic Of Suitable Rating, Testing And Commissioning Of Diesel Generating Set, Radiator Cooled, 3 Phase, 4 Wire, 50 Cycles 415 Plus (-)1% Volts Ac Alternator Coupled Directly Through S Set Of Flexible Coupling On A Common Ms Fabricated Base Frame With Diesel Engine Complete With Suitable Size Incoming Cable From Generator To Change Over/Amf Panel, Making 2Nd Incoming Cable Connection From Transformer, Outgoing Cable Connection From Changeover/ Standers Panel, Making Second Incoming Cable Connection From Transformer, Outgoing Cable Connection From Changeover/ Std Panel To Incomer Of Motor Starter Panel, Fenced Enclosure With Platform For Dg Sets Complete As Per Following Detailed Scope And Specification And Directions Of Engineer-In-Charge. The Rating Should Be At 1500 Rpm. A) Diesel Engine B) Alternator C C) Battery 24 V. D) Base Plate. E) Suitable Sq Mm Suitable Core Copper Cable Upto 40 Meters. F) Tools, Standard Panel. G) Metering, Set 415 Vac-1 Set (Amp. Meter, Volt Meter, Ass, Vss, Phase Indicator, Control Fuse, Frequency Meter, CtS) H) Metering Set 60/5A//440V (Amp. Meter, Volt Meter). I) Overload Protection For Dc-1 No. J) Battery Charger 24V Dc K) Copper Bus Bar Of Suitable Size L) Kwh Meter 96 Sq Mm Size M) Starting Fuse Button And Key Switch9on/Off N) Indicating Lamps For Low Lubricated Oil Pressure, High Coolant Temperature, Set Running, Load On, Dc Control And Other Required Accessories Complete In All Respects To The Satisfaction Of Engineer-In-Charge 7. 160 Kva (As Per Parameters Of Cpcb 4) 160 Kva (As Per Parameters Of Cpcb 4) , Clear Water Pump: Supplying, Erection, Testing And Commissioning Of Horizontal Motor Pumping Set For Clear Water Having Head As Per The Indicated Requirements Of Discharge In Lpm And Power Capacity In Bhp As Per Is Marked 8400 Lpm X 30.00 M Head (At Mbs) , Ns Item -Design, Construction, Erection And Commissioning Of 1 Ranneywell (Radial Collector Well) Of 10.00 Mld Capacity With Minimum Sinking Depth Of 30 Mtr And 1000 Mtr Long Laterals Pipe In 4 Layers, All Civil, Mechanical And Electrical Works Including Transformer As Per Design Along With All Accessories And Cables, Cubicai Type Lt/Ht Panels, Vcb Panels, All Types Of Cablings With Cable Tray, Chemical Earthings Of All Machineries, 4 Vt Pumps (3W Plus 1S) Having Capacity 180.00 M³/Hr. X 30 M Head, Vfd Panels, M.S Header With All Necessary Fittings, Gantry As Per Design, Electromagnetic Flow Meters At All Outlets And Inlets, Field Office (4 Mtr X 4 Mtr With Attach Toilet), Horticulture And Landscaping (3000 Sqm) Including Purchase Of 1.50 Acre Land (For Ranneywell, Mbs And Approach Path From Revenue Rasta To Well), Earth Filling In Ranneywell Complex. 1 High Mast Street Light 12.5 Mtr High Pole With 8 Luminous Lights, Wire / Cable, Switch. Mcb And Proper Foundation Etc Complete In All Respect. 10 Cp Plus Cctv Hd Coloured Night Vision Cameras And 1 360 Degree Dome Camera Fitted At 11 M. High Pole Along With Proper Foundation With Hd Night Vision. Plc/Scada Based Automation And Monitoring System. All The Pumping Machinery, Panel Board, Flow Meter, Level Sensor Etc Shall Be Controlled By Plc And Scada And Shall Be Synchronized With Plc Panels At Ranneywell And Mbs Site Through Broadband Internet Facility. The Work Will Be Carried Out Strictly As Per Detailed Scope Of Works, Specifications, Conditions Mentioned In The Dnit And Entire Satisfaction Of Engineer-In-Charge. (80 % Capital Cost Plus 20 % O/M Cost Payement Schedule Attached With Dnit.) , Hsr Itmes
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 2
Contract Date: Ref. Documents Contract Value : 2.55 Lakh
Local Bodies No of Bidders 1
10.
Educational and Research Institute #11408306 AOC
Bids Are invited for Providing and fixing 22.8 mm thick panels with bottom metal screen, intermediate fabric screens, and top screen in fabric magnetic finish, complete in all respects. Providing and placing NOVA make or equivalent free-standing pedestal with flat metal front of size 390 mm (W) × 435 mm (D) × 646 mm (H), comprising one drawer (1 box + 1 file) with central locking system, complete with all fittings and accessories. Providing and fixing Keyboard Platform Tray (KBPT) with integrated mouse tray, suitable for the workstation, complete in all respects. The complete workstation system shall be Greenguard (UL) certified and BIFMA LEVEL 2 certified. The manufacturer shall possess valid certifications of ISO 9001, ISO 45001, ISO 50001, IGBC, GRIHA and AIOTA, as applicable.The work includes transportation, loading, unloading, fixing, alignment, leveling, testing and commissioning, complete, as per approved drawings, specifications and directions of the Engineer-in-Charge , Supplying and placing in position executive main table with ERU and integrated pedestal of overall size 2350 × 2350 × 750 mm (H), comprising primary and secondary work surfaces made of 25 mm thick MDF, one side pre-laminated board conforming to IS:14587-1998, finished with 0.4 mm thick PVC membrane pressed on top, complete with soft-closing access flap and in-built power box for cable management. The modesty panel shall be of 25 mm thick MDF, one side pre-laminated board conforming to IS:14587-1998, finished with 0.4 mm thick PVC membrane pressed on top.The under-structure and integrated pedestal shall be made of 25 mm thick pre-laminated twin board of E1-P2 grade, conforming to IS:12823-1990, of approved shade, with all exposed edges edge-banded with matching 2 mm thick PVC lipping. The pedestal shall be of BOX-BOX-FILE configuration, having powder-coated metal panel drawer slides of 400 mm length with 325 mm drawer extension, provided with soft-closing and anti-slam mechanism, suitable handles, and central locking system, complete in all respects. The product shall be GREENGUARD (UL) certified, Indoor Advantage GOLD and GREENPRO certified, with manufacturer holding valid ISO 9001, ISO 45001, ISO 50001, IGBC, GRIHA and AIOTA certifications. The item includes transportation, loading, unloading, fixing, alignment and making functional, complete as per approved drawings, specifications and directions of the Engineer-in-Charge. , Supplying and placing in position back unit of overall size 2350 × 500 × 1800 mm (H), complete in all respects, having top panel made of 25 mm thick pre-laminated twin board of E1-P2 grade of approved shade conforming to IS:12823-1990, with all exposed edges edge-banded with matching 2 mm thick PVC lipping, sliding door storage unit with body panels including sides, bottom, back and shelves made of 25 mm thick pre-laminated twin board of E1-P2 grade conforming to IS:12823-1990 with 2 mm thick matching PVC edge banding, shutters made of 25 mm thick MDF, one side pre-laminated board conforming to IS:14587-1998 finished with 0.4 mm thick PVC membrane pressed on top, provided with soft-closing and anti-slam mechanism, suitable handles and locking arrangement, display/storage unit made of 25 mm thick pre-laminated twin board of E1-P2 grade conforming to IS:12823-1990 with 2 mm thick PVC lipping for sides, back and shelves, doors made of 25 mm thick MDF, one side pre-laminated board conforming to IS:14587-1998 finished with 0.4 mm thick PVC membrane pressed on top, and top panel of display unit also made of 25 mm thick MDF finished similarly, the complete unit being GREENGUARD (UL), Indoor Advantage GOLD and GREENPRO certified, with manufacturer holding valid ISO 9001, ISO 45001, ISO 50001, IGBC, GRIHA and AIOTA certifications, including transportation, loading, unloading, fixing, alignment and making the unit fully functional, complete as per approved drawings, specifications and directions of the Engineer-in-Charge. , Providing, supplying and placing in position high back executive chair, complete in all respects, having cushioned seat made of injection-moulded plastic outer and inner, inner upholstered in pure leather with moulded High Resilience (HR) polyurethane foam of density 45 ± 2 kg/m³ and hardness load 16 ± 2 kgf at 25% compression, cushioned back made of PU foam with in-situ moulded M.S. E.R.W. round tube of size 1.9 ± 0.03 cm dia × 0.16 ± 0.0128 cm thick, upholstered in pure leather, seat size 47.6 cm (W) × 49.2 cm (D) and back size 47.5 cm (W) × 77.0 cm (H), PU moulded armrest tops upholstered in pure leather mounted on drop-lift adjustable M.S. E.R.W tubular arm supports of size 3.81 ± 0.03 cm × 0.2 ± 0.01 cm thick with chrome-plated finish, height adjustable up to 6.5 ± 0.5 cm in five steps, provided with active bio-synchro mechanism having 360° revolving, front-pivot tilt with continuous lumbar support, tilt tension adjustment operable in seating position, five-position tilt limiter and seat/back tilting ratio of 1:2, mechanism housing made of HPDC aluminium black powder-coated, provided with seat depth adjustment through integrated sliding mechanism with adjustment range of 6.0 ± 0.5 cm, adjustable back support through up/down mechanism housed in plastic T-spine with adjustment range of 7.42 ± 0.5 cm, pneumatic height adjustment with stroke of 10.0 ± 0.3 cm, pedestal made of high-pressure die-cast polished aluminium fitted with five twin-wheel castors of injection-moulded black polypropylene, pedestal pitch-centre dia 65.0 ± 0.5 cm (75.0 ± 1.0 cm with castors), overall seat height 44.5 to 54.5 cm, overall height 114.0 to 131.5 cm and overall width and depth 76.1 cm each, including transportation, loading, unloading and placing in position, complete as per specifications and directions of the Engineer-in-Charge. , Providing, supplying and placing in position visitor chair, complete in all respects, having cushioned seat made of injection-moulded plastic outer and inner, inner upholstered in pure leather with moulded High Resilience (HR) polyurethane foam of density 45 ± 2 kg/m³ and hardness load 16 ± 2 kgf at 25% compression, cushioned back made of PU foam with in-situ moulded M.S. E.R.W. round tube of size 1.9 ± 0.03 cm dia × 0.16 ± 0.0128 cm thick, upholstered in pure leather, seat size 47.6 cm (W) × 49.2 cm (D) and back size 46.5 cm (W) × 59.5 cm (H), provided with cantilever type tubular frame made of SS-202 tube of size Ø 2.54 ± 0.03 cm × 0.02 ± 0.016 cm thick, back connected to frame through chrome-plated high-pressure die-cast connector, overall seat height 46.2 cm, overall height 98.2 cm, overall width 60.9 cm and depth 64.7 cm, the product being GREENGUARD (UL) and BIFMA LEVEL-2 certified, with manufacturer holding valid ISO 9001, ISO 45001, ISO 50001, IGBC, GRIHA and AIOTA certifications, including transportation, loading, unloading and placing in position, complete as per specifications and directions of the Engineer-in-Charge. , Supplying and placing in position main table of overall size 1800 × 900 × 750 mm (H), complete in all respects, having work surface made of a combination of 25 mm thick MDF, one side pre-laminated board conforming to IS:14587-1998 finished with 0.4 mm thick PVC membrane pressed on top, and 25 mm thick pre-laminated twin board of E1-P2 grade of approved shade conforming to IS:12823-1990, with all exposed edges edge-banded with matching 2 mm thick PVC lipping, provided with soft-closing access flap and in-built power box on work surface for wire management, modesty panel made of 25 mm thick MDF, one side pre-laminated board conforming to IS:14587-1998 finished with 0.4 mm thick PVC membrane pressed on top, under-structure made of 25 mm thick pre-laminated twin board of E1-P2 grade conforming to IS:12823-1990 with 2 mm thick matching PVC lipping, integrated pedestal made of 25 mm thick pre-laminated twin board of E1-P2 grade conforming to IS:12823-1990 with 2 mm thick PVC edge banding, drawer fronts made of 25 mm thick MDF one side pre-laminated board conforming to IS:14587-1998 finished with 0.4 mm thick PVC membrane pressed on top, pedestal of BOX-BOX-FILE configuration using powder-coated metal panel drawer slides of 400 mm length with 325 mm drawer extension, provided with soft-closing and anti-slam mechanism, suitable handles and locking arrangement for security, the product being GREENGUARD (UL) certified, with manufacturer holding valid ISO 9001, ISO 45001, ISO 50001, IGBC, GRIHA and AIOTA certifications, including transportation, loading, unloading, fixing, alignment and making the unit fully functional, complete as per approved drawings, specifications and directions of the Engineer-in-Charge. , Providing, supplying and placing in position mid back chair, complete in all respects, having seat made of 1.5 ± 0.1 cm thick hot-pressed plywood upholstered with fabric upholstery covers and moulded polyurethane foam, with extra thick foam at the front edge for comfort to the popliteal area, back made of injection-moulded glass-filled polypropylene upholstered with mesh fabric and provided with adjustable lumbar support made of injection-moulded polypropylene with adjustment range of 5.0 ± 0.1 cm, seat size 53.5 cm (W) × 51.0 cm (D) and mesh back size 51.0 cm (W) × 70.0 cm (H), seat foam of High Resilience (HR) polyurethane moulded with density 45 ± 2 kg/m³ and hardness 16 ± 2 kgf as per IS:7888 at 25% compression, provided with adjustable armrests having up-down adjustment in six steps (7.2 ± 0.5 cm range) with armrest top PU-moulded over glass-filled nylon insert and mounted on armrest structure made of glass-filled nylon, provided with centre tilt synchro mechanism with multi-lock having 360° revolving, three-position locking with anti-shock mechanism and tilt tension adjustment, pneumatic height adjustment with stroke of 9.5 ± 0.3 cm, pedestal assembly made of injection-moulded glass-filled nylon fitted with five twin-wheel castors, pedestal pitch-centre diameter 66.1 ± 0.5 cm (76.1 ± 1.0 cm with castors), twin-wheel castors injection-moulded in black nylon, overall width 76.1 cm, depth 76.1 cm, height 101.5 to 111.0 cm and seat height 44.5 to 54.0 cm, the product being GREENGUARD (UL) and BIFMA LEVEL-2 certified, with manufacturer holding valid ISO 9001, ISO 45001, ISO 50001, IGBC, GRIHA and AIOTA certifications, including transportation, loading, unloading and placing in position, complete as per specifications and directions of the Engineer-in-Charge. , Providing, supplying and placing in position visitor chair, complete in all respects, having single shell seat and back made of 1.2 ± 0.1 cm thick hot-pressed plywood, upholstered with moulded polyurethane foam on top and backing foam on rear side, finished with knitted fabric or leatherette upholstery, with extra thick foam at the front edge for comfort to the popliteal area, High Resilience (HR) polyurethane foam for seat and back moulded with density 45 ± 2 kg/m³ and hardness load 16 ± 2 kgf as per IS:7888 at 25% compression, provided with cantilever type visitor tubular frame made of M.S. E.R.W. tube of size Ø 2.54 ± 0.03 cm × 0.2 ± 0.016 cm thickness, powder coated finish of DFT 40–60 micron, armrest tops moulded from polyurethane (PU) with metal insert and mounted on tubular frame, overall width 60.5 cm, depth 65.0 cm, height 86.5 cm and seat height 46.0 cm, the product being GREENGUARD (UL) and BIFMA LEVEL-2 certified, with manufacturer holding valid ISO 9001, ISO 45001, ISO 50001, IGBC, GRIHA and AIOTA certifications, including transportation, loading, unloading and placing in position, complete as per specifications and directions of the Engineer-in-Charge. , Providing, supplying and placing in position ergonomic task chair, complete in all respects, having cushioned seat assembly with seat base moulded in glass-filled poly-amide, moulded polyurethane foam upholstered with high-stretch knitted polyester fabric, back injection-moulded in glass-filled polypropylene upholstered with mesh fabric and provided with adjustable lumbar support made of injection-moulded polypropylene with adjustment range of 3.0 ± 0.1 cm, mesh back size 45.5 cm (W) × 54.0 cm (H) and seat size 48.5 cm (W) × 49.0 cm (D), High Resilience (HR) polyurethane foam used in seat and back cushions moulded with minimum density 48 kg/m³ and hardness load 15 ± 2 kgf as per IS:7888 at 25% compression, seat and back firmly connected to base frame and cantilevered to allow multi-dimensional movement with impact cushioning and synchronized seat-back motion during posture changes, back-spine structure comprising “S” shaped spines and spine connector moulded in high-strength glass-filled poly-amide, provided with variable tilt angle recline adjustable through three-position tilt limit feature inbuilt in seat base with user-weight dependent return force, armrest assembly consisting of armrest housing sliding over armrest structure both moulded in glass-filled poly-amide, with button-operated height adjustment of 6.6 ± 0.5 cm, armrest top of integral skin PU moulded over plastic inner moulded in glass-filled poly-amide, pneumatic gas-lift height adjustment with stroke of 9.2 ± 0.3 cm, pedestal made of injection-moulded glass-filled poly-amide having pitch-centre diameter 66.0 ± 0.5 cm (76.0 ± 1.0 cm with castors), fitted with five twin-wheel castors injection-moulded in poly-amide of 5.0 ± 0.1 cm wheel diameter, the product being GREENGUARD (UL) and BIFMA LEVEL-2 certified, with manufacturer holding valid ISO 9001, ISO 45001, ISO 50001, IGBC, GRIHA and AIOTA certifications, including transportation, loading, unloading and placing in position, complete as per specifications and directions of the Engineer-in-Charge. , Providing, supplying and placing in position high back chair, complete in all respects, having cushioned seat assembly with seat base moulded in glass-filled poly-amide, moulded polyurethane foam upholstered with high-stretch knitted polyester fabric, cushioned back assembly with back inner moulded in polypropylene, in-situ moulded with polyurethane foam and upholstered with high-stretch knitted polyester fabric, seat size 48.5 cm (W) × 47.0 cm (D) and back size 45.5 cm (W) × 53.0 cm (H), High Resilience (HR) polyurethane foam used in seat and back cushions moulded with minimum density 48 kg/m³ and hardness load 15 ± 2 kgf as per IS:7888 at 25% compression, seat and back firmly connected to base frame and cantilevered to provide multi-dimensional movement, impact cushioning while sitting and synchronized seat-back movement during posture changes, back-spine structure comprising “S” shaped spines and spine connector moulded in high-strength glass-filled poly-amide, provided with variable tilt angle recline adjustable through three-position tilt limit feature inbuilt in seat base with user-weight dependent return force, adjustable armrests comprising armrest housing sliding over armrest structure both moulded in glass-filled poly-amide with button-operated height adjustment of 6.6 ± 0.5 cm, armrest top of integral skin PU moulded over plastic inner moulded in glass-filled poly-amide, pneumatic gas-lift height adjustment with stroke of 9.2 ± 0.3 cm, pedestal assembly made of injection-moulded glass-filled poly-amide having pitch-centre diameter 66.0 ± 0.5 cm (76.0 ± 1.0 cm with castors), fitted with five twin-wheel castors injection-moulded in poly-amide of 5.0 ± 0.1 cm wheel diameter, overall seat height 44.5 to 53.8 cm, overall height 99.5 to 108.8 cm and overall width and depth 76.0 cm each, the product being GREENGUARD (UL) and BIFMA LEVEL-2 certified, with manufacturer holding valid ISO 9001, ISO 45001, ISO 50001, IGBC, GRIHA and AIOTA certifications, including transportation, loading, unloading and placing in position, complete as per specifications and directions of the Engineer-in-Charge. , Supplying and placing in position 24-seater conference table (MINGLE MODULAR PLT), complete in all respects, having worksurface made of 25 mm thick pre-laminated twin board of E1-P2 grade of approved shade conforming to IS:12823:1990, with all exposed edges edge-banded with 2 mm thick matching PVC lipping, understructure made of 18 mm thick pre-laminated twin board of E1-P2 grade of approved shade conforming to IS:12823:1990, edge-banded with 2 mm thick matching PVC lipping, aluminium alloy 63400-WP profiles used for connecting panels together with knock-down construction, provided with plastic ABS access flap for easy access to wires and cables, worktop available in various modular shapes, modesty panel made of 18 mm thick pre-laminated twin board of E1-P2 grade conforming to IS:12823:1990, edge-banded with 2 mm thick PVC lipping, powder-coated accent metal strip below work surface made of 0.8 mm CRCA as per IS:513, epoxy polyester powder coated (DFT 40–60 microns), wire management panels made of 0.8 mm CRCA MS IS:513, epoxy polyester powder coated (DFT 40–60 microns), provision to mount Anchor Roma 6 module plate below worktop, and cutouts on top with two-piece injection-moulded plastic component for pulling audio/video cables and connecting devices to power sockets below worktop, the product being GREENGUARD (UL), Indoor Advantage GOLD, GRIHA, SVAGRIHA and GREENPRO certified, with manufacturer holding valid ISO 9001, ISO 45001, ISO 50001, IGBC, GRIHA and AIOTA certifications, including transportation, loading, unloading, fixing, alignment and making the unit fully functional, complete as per approved drawings, specifications and directions of the Engineer-in-Charge. , Supplying and placing in position 16-seater conference table (MINGLE MODULAR PLT), complete in all respects, having worksurface made of 25 mm thick pre-laminated twin board of E1-P2 grade of approved shade conforming to IS:12823:1990, with all exposed edges edge-banded with 2 mm thick matching PVC lipping, understructure made of 18 mm thick pre-laminated twin board of E1-P2 grade of approved shade conforming to IS:12823:1990, edge-banded with 2 mm thick matching PVC lipping, aluminium alloy 63400-WP profiles used for connecting panels together with knock-down construction, provided with plastic ABS access flap for easy access to wires and cables, worktop available in various modular shapes, modesty panel made of 18 mm thick pre-laminated twin board of E1-P2 grade conforming to IS:12823:1990, edge-banded with 2 mm thick matching PVC lipping, powder-coated accent metal strip below work surface made of 0.8 mm CRCA as per IS:513, epoxy polyester powder coated (DFT 40–60 microns), wire management panels made of 0.8 mm CRCA MS IS:513, epoxy polyester powder coated (DFT 40–60 microns), provision to mount Anchor Roma 6 module plate below worktop, and cutouts on top with two-piece injection-moulded plastic component for pulling audio/video cables and connecting devices to power sockets below worktop, the product being GREENGUARD (UL), Indoor Advantage GOLD, GRIHA, SVAGRIHA and GREENPRO certified, with manufacturer holding valid ISO 9001, ISO 45001, ISO 50001, IGBC, GRIHA and AIOTA certifications, including transportation, loading, unloading, fixing, alignment and making the unit fully functional, complete as per approved drawings, specifications and directions of the Engineer-in-Charge , Supplying and placing in position 12-seater conference table (MINGLE MODULAR PLT), complete in all respects, having worksurface made of 25 mm thick pre-laminated twin board of E1-P2 grade of approved shade conforming to IS:12823:1990, with all exposed edges edge-banded with 2 mm thick matching PVC lipping, understructure made of 18 mm thick pre-laminated twin board of E1-P2 grade of approved shade conforming to IS:12823:1990, edge-banded with 2 mm thick matching PVC lipping, aluminium alloy 63400-WP profiles used for connecting panels together with knock-down construction, provided with plastic ABS access flap for easy access to wires and cables, worktop available in various modular shapes, modesty panel made of 18 mm thick pre-laminated twin board of E1-P2 grade conforming to IS:12823:1990, edge-banded with 2 mm thick matching PVC lipping, powder-coated accent metal strip below work surface made of 0.8 mm CRCA as per IS:513, epoxy polyester powder coated (DFT 40–60 microns), wire management panels made of 0.8 mm CRCA MS IS:513, epoxy polyester powder coated (DFT 40–60 microns), provision to mount Anchor Roma 6 module plate below worktop, and cutouts on top with two-piece injection-moulded plastic component for pulling audio/video cables and connecting devices to power sockets below worktop, the product being GREENGUARD (UL), Indoor Advantage GOLD, GRIHA, SVAGRIHA and GREENPRO certified, with manufacturer holding valid ISO 9001, ISO 45001, ISO 50001, IGBC, GRIHA and AIOTA certifications, including transportation, loading, unloading, fixing, alignment and making the unit fully functional, complete as per approved drawings, specifications and directions of the Engineer-in-Charge. , Supply and fixing wooden storage unit of size 1200 × 450 × 1219 mm (H), complete in all respects, comprising low to medium height HDU, with body made of 18 mm pre-laminated board (PLB) with all edges sealed with 0.8 mm thick PVC edgeband, back panel made of 9 mm white pre-laminated board (PLT), complete ready-to-assemble construction using suitable knock-down (KD) fittings, shelves and separator panels (where provided) made of 18 mm white PLT with 0.8 mm edge banding, bottom shelf fixed and other shelves with one-step adjustable positions for optimized storage, door panels made of 18 mm PLB with 2 mm edge banding on all edges, fitted with flush plastic handle vertically at center, doors mounted on suitable hinges with HDU fitted with adjustable height fittings, three-point locking arrangement provided, and all units fitted with 6 mm levelers at the bottom for proper leveling, the product being GREENGUARD (UL) and BIFMA LEVEL-2 certified, with manufacturer holding valid ISO 9001, ISO 45001, ISO 50001, IGBC, GRIHA and AIOTA certifications, including transportation, loading, unloading, fixing, alignment and making the unit fully functional, complete as per approved drawings, specifications and directions of the Engineer-in-Charge. , Supplying and placing in position one-seater sofa, complete in all respects, having seat foam made of PU foam with density 28 ± 2 kg/m³ and an additional top layer of supersoft PU foam with density 32 ± 2 kg/m³, upholstered in fabric or leatherette, back foam made of PU foam with density 28 ± 2 kg/m³ and two additional top layers of supersoft PU foam with density 32 ± 2 kg/m³, upholstered in fabric or leatherette, understructure made of 1.2 ± 0.1 cm thick hot-pressed plywood (moisture-resistant and termite-proof as per IS:303) and pinewood cross-sections free from major knots and surface defects, zigzag spring assembly comprising 6 nos. per seat with 3.8 mm dia mounted over understructure for cushioning, leg assembly welded in stainless steel (grade SS 202) tube and plate with plastic end caps, overall dimensions width 86.0 cm, depth 90.5 cm, height 85.5 cm, seat height 45.0 cm, including transportation, loading, unloading, fixing, alignment and making the unit fully functional, complete as per approved drawings, specifications and directions of the Engineer-in-Charge. , Supplying and placing in position two-seater sofa, complete in all respects, having seat foam made of PU foam with density 28 ± 2 kg/m³ and an additional top layer of supersoft PU foam with density 32 ± 2 kg/m³, upholstered in fabric or leatherette, back foam made of PU foam with density 28 ± 2 kg/m³ and two additional top layers of supersoft PU foam with density 32 ± 2 kg/m³, upholstered in fabric or leatherette, understructure made of 1.2 ± 0.1 cm thick hot-pressed plywood (moisture-resistant and termite-proof as per IS:303) and pinewood cross-sections free from major knots and surface defects, zigzag spring assembly comprising 6 nos. per seat with 3.8 mm dia mounted over understructure for cushioning, leg assembly welded in stainless steel (grade SS 202) tube and plate with plastic end caps, overall dimensions width 172.0 cm, depth 90.5 cm, height 85.5 cm, seat height 45.0 cm, including transportation, loading, unloading, fixing, alignment and making the unit fully functional, complete as per approved drawings, specifications and directions of the Engineer-in-Charge. , Supplying and placing in position three-seater sofa, complete in all respects, having seat foam made of PU foam with density 28 ± 2 kg/m³ and an additional top layer of supersoft PU foam with density 32 ± 2 kg/m³, upholstered in fabric or leatherette, back foam made of PU foam with density 28 ± 2 kg/m³ and two additional top layers of supersoft PU foam with density 32 ± 2 kg/m³, upholstered in fabric or leatherette, understructure made of 1.2 ± 0.1 cm thick hot-pressed plywood (moisture-resistant and termite-proof as per IS:303) and pinewood cross-sections free from major knots and surface defects, zigzag spring assembly comprising 6 nos. per seat with 3.8 mm dia mounted over understructure for cushioning, leg assembly welded in stainless steel (grade SS 202) tube and plate with plastic end caps, overall dimensions width 206.0 cm, depth 90.5 cm, height 85.5 cm, seat height 45.0 cm, including transportation, loading, unloading, fixing, alignment and making the unit fully functional, complete as per approved drawings, specifications and directions of the Engineer-in-Charge. , Supplying and placing in position three-seater sofa, complete in all respects, overall dimensions width 176.5 cm, depth 81.5 cm, height 83.5 cm, upholstered in PVC material of 1 mm thickness in coffee brown shade, frame made of pine wood with moisture content 10–12%, plywood used in frame 12 mm and 18 mm thick, seat cushion made of slab stock foam with density 32 kg/m³, back and armrest cushions filled with conjugated hollow fiber (recron), webbing made of nylon, legs made of PVC, including transportation, loading, unloading, fixing, alignment and making the unit fully functional, complete as per approved drawings, specifications and directions of the Engineer-in-Charge. , Providing, supplying and placing in position coffee table, complete in all respects, overall size 1202 × 594 × 411 mm (W × D × H), body made of 18 mm pre-laminated particle board (PLB) with all exposed edges edge-banded with 2 mm thick PVC, middle horizontal panel providing storage area, four nylon bushes provided, top comprising 8 mm thick toughened glass glued with UV plate and PLT panel, glass fixed to side vertical panels, PLT top panel hinged to side vertical panels to open upwards, knock-down construction, finish in WENGE shade with suede finish on PLT panels and Sunray finish on UV-glued plates under glass, hardware comprising dowels for knock-down assembly with high-quality standard hardware including screws, door hinges, bumpers, expanding sockets, nylon bushes, etc., including transportation, loading, unloading, fixing, alignment and making the unit fully functional, complete as per approved drawings, specifications and directions of the Engineer-in-Charge. , Supplying and placing in position coffee table, complete in all respects, overall size 1100 × 600 × 456 mm (L × W × H), table-top made of 8 mm thick toughened clear glass, body made of 18 mm thick pre-laminated board (PLT) in Cincinnati Walnut finish, configuration comprising shelf storage and display space, including transportation, loading, unloading, fixing, alignment and making the unit fully functional, complete as per approved drawings, specifications and directions of the Engineer-in-Charge. , Supplying and placing in position corner table, complete in all respects, overall size 450 × 450 × 606 mm (L × W × H), table-top made of 6 mm thick toughened clear glass, body made of 18 mm thick pre-laminated board (PLT) in Cincinnati Walnut finish, configuration comprising shelf storage and display space, including transportation, loading, unloading, fixing, alignment and making the unit fully functional, complete as per approved drawings, specifications and directions of the Engineer-in-Charge. , Supplying and placing in position corner table, complete in all respects, overall dimensions 60 × 45 × 60 cm (W × H × D), made of 18 mm thick pre-laminated particle board (PLB) with 10 mm thick toughened glass top, construction knock-down type, finish comprising MIP lamination in Black Ink shade with matching matt PVC lipping and digitally printed glass matching the PLB finish, including transportation, loading, unloading, fixing, alignment and making the unit fully functional, complete as per approved drawings, specifications and directions of the Engineer-in-Charge. , Supplying and placing in position main table of overall size 1220 × 600 × 750 mm (L × W × H), complete in all respects, work surface made of 25 mm thick pre-laminated board of E1-P2 grade of approved shade conforming to IS:12823:1990, all exposed edges edge-banded with 2 mm thick PVC lipping, access flap provided on work surface for wire management, understructure made of 18 mm thick pre-laminated twin board of E1-P2 grade of approved shade conforming to IS:12823:1990, edge-banded with 2 mm thick PVC lipping, cube legs fabricated from MS ERW tube 50 × 25 × 1.2 mm and 40 × 40 × 1.2 mm as per IS:7138, top of legs welded with 3 mm thick HR steel support brackets (IS:2062) for fixing worktop, welded structure coated with 50 micron epoxy polyester, base fitted with plastic cap with M8 molded insert and straight M8 leveler adjustable up to 50 mm, cross members made from 50 × 25 × 1.2 mm ERW tube (IS:7138), coated with 50 micron epoxy polyester, assembled by friction-fit PDC joinery and grub screws, two cross members per table, power box made of 0.8 mm thick CRCA (IS:513) with 8-module Anchor Roma cutout fixed along the depth of worktop, soft-closing access flap made of aluminum extrusion with PDC parts in aluminum alloy and plastic parts in Nylon 6, wire brush with nylon bristles for cable management, the product being GREENGUARD (UL) certified, with manufacturer holding valid ISO 9001, ISO 45001, ISO 50001, IGBC, GRIHA and AIOTA certifications, including transportation, loading, unloading, fixing, alignment and making the unit fully functional, complete as per approved drawings, specifications and directions of the Engineer-in-Charge. , Providing and placing in position high-back (HB) chair, complete in all respects, with cushioned seat made of injection-molded plastic outer and inner, inner upholstered with leatherette and moulded high resilience (HR) polyurethane foam of density 45 ± 2 kg/m³ and hardness load 16 ± 2 kgf as per IS:7888 for 25% compression; cushioned back made of PU foam with in-situ molded MS ERW round tube 1.9 ± 0.03 cm × 0.16 ± 0.0128 cm, upholstered with leatherette, seat size 47.0 × 48.0 cm (W × D), high-back size 47.7 × 76.4 cm (W × H); armrest top moulded in PU, mounted on drop-lift adjustable tubular support of 3.81 ± 0.03 cm × 0.2 ± 0.01 cm MS ERW tube with chrome finish, height adjustable up to 6.5 ± 0.5 cm in 5 steps; active bio-synchro mechanism with 360° revolving type, front-pivot tilt with feet resting on ground, continuous lumbar support, tilt tension adjustable in seating position, 5-position tilt limiter, seat/back tilting ratio 1:2, mechanism housing of HPDC aluminium black powder coated, seat depth adjustable 6.0 ± 0.5 cm, adjustable back support connected to Up/Down mechanism housed in plastic T-spine adjustable 7.42 ± 0.5 cm, pneumatic height adjustment stroke 10.0 ± 0.3 cm, pedestal of high-pressure die-cast polished aluminium fitted with 5 twin-wheel castors, pedestal pitch-center diameter 65.0 ± 0.5 cm (75.0 ± 1.0 cm with castors), twin-wheel castors injection-moulded black PP, wheel diameter 6.0 ± 0.1 cm, overall chair dimensions: seat height 43.1–53.1 cm, height 112.7–130.2 cm, width & depth 76.1 × 76.1 cm, including transportation, loading, unloading, fixing, alignment and making the unit fully functional, certified Greenguard (UL) and BIFMA LEVEL 2, manufacturer holding ISO 9001, ISO 45001, ISO 50001, IGBC, GRIHA and AIOTA certifications, complete as per approved drawings, specifications and directions of the Engineer-in-Charge. Total Quantity : 172
Contract Date: Ref. Documents Contract Value : 42.59 Lakh
Government Departments No of Bidders 5
11.
Defence #11408076 AOC
Bids Are invited for Cleanroom Equipment And Electrostatic Discharge Protection Solutions Ultra-Pure Nitrogen Distribution And Energy Optimization System For Controlled Environments , Contamination-Controlled Garment Storage And Suspension System , Esd-Compliant Ergonomic Seating System With Integrated Armrests For Controlled Environments , Static Dissipative Work Surface Assembly With Bench-Mounted Ionization Module , Integrated Electrostatic Discharge Control And Measurement System For Cleanroom Applications , Controlled Environment Particulate Extraction And Air Displacement Unit , Portable Particle Quantification Unit For Controlled Environments , Cleanroom-Compatible Portable Particle Monitoring System , Lightweight Maintenance And Access Platforms For Controlled Environments , Industrial Weighing And Load Measurement Systems - Platform And Suspended Crane Type , Static Dissipative Storage Container And Bin System For Subsystem Protection And Organization , Air-Tight Cleanroom Access Door With Overhead Closure And Controlled Airflow Interface , Controlled Cleanroom Utility System, Transport, And Cleaning Assembly With Esd Safe , Controlled Environment Protective Wear And Static Dissipative Consumables For Personnel Safety , Electrostatic Discharge Control Accessories And Cleanroom Contamination Control Materials , Footwear Organization And Storage Assembly With Self-Closing Access Mechanism For Cleanroom Applications , Cleanroom Monitoring And Access Control System With Environmental Display , Esd-Safe Cleanroom Consumables For Surface Cleaning, Particle Removal, And Static-Protected Packaging , Electrostatic Discharge Safe Precision Handling And Assembly Tool Kit For Electronic Component , Integrated Differential Pressure Measurement With Silicone-Free Sealing System For Cleanroom Applications , Cleanroom-Compatible Waste Collection Bins With Liner Provision Total Quantity : 2066
Contract Date: Ref. Documents Contract Value : 4.24 Crore
Government Departments No of Bidders 8
Contract Date: Ref. Documents Contract Value : 2.89 Crore
Government Departments No of Bidders 1
Maharashtra View Result →
14.
Water Resources and Irrigation #11342285 AOC
Amrut-Supply, Erecting And Commissioning Of Various Pump Sets, Other Necessary Equipment For 107 Mld Sewerage Treatment Plant At Muttathara-Supply, Erecting And Commissioning Of Various Pump Sets, Other Necessary Equipments For 107 Mld Sewerage Treatment Plant At Muttathara-Sewerage Work- 1 SUPPLY, ERECTING AND COMMISSIONING OF PUMP SETS 2 OD149149/2023-2024:Supply, Erecting and Commissioning of 75 HP non clog pump set for RAS (Head – Up to 20 M) 3 OD149154/2023-2024:Supply, Erection and Commissioning of 5 HP non clog pump set for WAS (Total Head :14 M ) 4 OD149153/2023-2024:Supply, Erecting and Commissioning of 5 HP centrifugal dewatering pump set for RAS 5 OD17699/2025-2026:Supply, Erecting and Commissioning of80 HP Submersible pump set for inlet(Head : Up to 20 M) 6 OD18102/2025-2026:Supply, installation, and commissioning of minimum 100 LPH RO water purifier of standard make with 304-grade stainless steel skid and housing, comprising multi-stage purification system including pre-filter, sediment filter, activated carbon filter, RO membrane, UV disinfection unit, auto-flush system, and mineral cartridge; suitable for continuous commercial use and delivering safe, high-quality drinking water. 7 OD18758/2025-2026:Supply of 10 HP portable submersible sludge pump, 3-phase, suitable for handling slurry and sewage, maximum head up to 20 meters, solid handling capacity up to 50 mm, abrasion-resistant impeller, thermal protection, 15 m power cable, and 30 meters of heavy-duty discharge hose (100 mm dia) with quick couplings. 8 Supply and installation soft starter and motorized chain pulley 9 OD149170/2023-2024:Supply of motorized chain pulley block with 3-ton lifting capacity and 10-meter lift height, featuring electric motorized operation with electromagnetic or disc brake system, pendant control for easy operation, limit switches for safety, and overload protection, conforming to IS/ISO standards. 10 OD16970/2025-2026:Supply and installation of soft starter for MCC unit ( For 60 HP motor XS4000,115A,M200-525VACC110/ 220VAC), MNX140 3P 240V CONTACTOR and SEMI CONDUCTOR FUSE 170M3015 11 OD18097/2025-2026:Supplying, fixing, and testing 50W LED hanging type well glass light, weatherproof (IP65) 12 OD18264/2025-2026:Supply and installation of 10-meter hot-dip galvanized double-arm octagonal street light pole with 2×120W LED luminaires, including internal wiring, weatherproof junction box, connections, and earthing. Complete with foundation bolts and RCC pedestal. Includes supply, erection, and commissioning 13 Installation of CCTV camera 14 OD16801/2025-2026:Supplying & fixing HIKVISION 5 MP Varifocal IP Bullet Camera CAMERA 15 OD16892/2025-2026:Supplying, fixing and commissioning 4MP IP DOME CAMERA 16 OD16891/2025-2026:Supplying, fixing and commissioning HIKVISION 4MP IP BULLET CAMERA 40M 17 OD16890/2025-2026:Supplying, fixing and commissioning HIKVISION 32CH NVR 18 OD16889/2025-2026:Supplying, fixing and commissioning 8 PORT POE SWITCH 19 OD16888/2025-2026:Supplying & fixing 6U RACK & ACCESSORIES 20 OD16887/2025-2026:Supplying & fixing 9U RACK& ACCESSORIES 21 OD16886/2025-2026:Supplying & fixing CAMERA BOX 22 OD16885/2025-2026:Supplying & fixing CAT6 CABLE & PIPING (including excavation) 23 OD16884/2025-2026: Supplying and fixing pole with all accessories. 24 OD16920/2025-2026:Supplying and fixing 55-inch, 4K, LED, Smart TV (Samsung/LG/Sony) 25 OD16919/2025-2026:Supplying & fixing RECEIVER & TRANSMITTER UNIT 26 OD16918/2025-2026:Supplying & fixing L & T EXTENSION 5MTR 27 OD16917/2025-2026:Supplying & fixing 5 PORT GIGABYTE SWITCH 28 OD16916/2025-2026:Supplying & fixing HDMI CABLE 3MTR 29 OD16915/2025-2026:Supplying & fixing RACK & PIPE ACCESSORIES, 30 OD16914/2025-2026:INSTALLATION CHARGE FOR CAMERA& NVR 31 OD16913/2025-2026:Supplying & installation of rack 32 New Road formation: Tarring inside STP compound 33 3.6:Excavation for roadwork in soil with hydraulic excavator of 0.9 cum bucket capacity including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross sections, and transporting to the embankment location within all lifts and lead upto 1000m 34 4.1.B.1:Construction of granular sub-base by providing graded material, spreading in uniform layers with a motor grader on a prepared surface, mixing by mix in-place method with rotavator at OMC, and compacting with a vibratory roller to achieve the desired density, complete as per clause 401. Grading-V - For sub-base cum drainage layer - Mix in Place Method 35 4.12:Providing, laying, spreading and compacting graded stone aggregate to Wet Mix Macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver in sub- base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density. 36 5.1.a:Providing and applying primer coat with bitumen emulsion ( SS) on prepared surface of granular Base including clearing of road surface and spraying primer at the rate of 0.70 - 1.0 kg/sqm using mechanical means. 37 5.2.a:Providing and applying tack coat with bitumen emulsion( RS) using emulsion pressure distributor at the rate of 0.20 - 0.30 kg per sqm on the prepared bituminous surface cleaned with mechanical broom. 38 OD18679/2025-2026:Providing 40mm premixed chipping carpet over BT surface with departmental broken stones after thoroughly cleaning the base with wire brushes, brooms and applying a priming coat of hot bitumen @2.50Kg/10m2 and spreading the hot premix of 0.32m3 of 24mm, 0.22m3 of 12mm departmental metal mixed with 22.08Kg of bitumen per 10m2, rolling to dense surface, then spreading the seal coat comprising of 0.09m3 of 6mm metal mixed with 8.64kg of bitumen per 10m2 and rolling again including cost of bitumen, fuel, hire charges machineries etc. complete excluding the cost of 24mm ,12mm ,6mm metal(Total usage of bitumen 33.22 Kg per 10m2) (I.R.C 3.4.2) 39 OD18716/2025-2026:Supplying and stacking 24mm hard blue granite broken stone in standard heaps-for measurement(IRC 3.2. 1.a) 40 55.2:Supplying and stacking 12mm hard blue granite broken stone in standard heaps for measurement(IRC 3.2.1.a) 41 55.3:Supplying and stacking 6mm hard blue granite broken stone in standard heaps for measurement(IRC 3.2.1.a) 42 Infrastructure Improvement Works at STP 43 OD17712/2025-2026:Supply and installation of UV-resistant HDPE with 12mm mesh ( 2meter height) for durability. Support poles are galvanized iron pipes (2-inch dia, 6 ft height) for stability. Stainless steel clamps & UV-resistant plastic ties ensure secure fitting. Concrete footing with excavation and earthwork provides pole stability. Skilled labor ensures proper installation 44 OD17711/2025-2026:Supply and spray a non-toxic, bio-friendly herbicide or a selective herbicide, with an application rate of 5 to 10 liters per hectare, ensuring effective weed control over an area of 1 hectare. 45 2.31:Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared 46 2.32:Clearing grass and removal of the rubbish up to a distance of 50 m outside the periphery of the area cleared. 47 4.2.5:Providing and laying cement concrete in retaining walls, return walls, walls ( any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts,buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor, etc. up to floor five level, excluding the cost of centering, shuttering and finishing:1:3:6 ( 1 cement : 3 coarse sand :6 graded stone aggregate 20 mm nominal size) 48 4.3.1:Centering and shuttering including strutting, propping etc. and removal of form work for:Foundations, footings, bases for columns 49 5.22.4:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelHot rolled deformed bars 50 OD17710/2025-2026:Supply & installation of high-quality polyester sun control film with UV-blocking, heat resistance (99% UV, 60% heat rejection), 2–4 mil thickness, bubble-free installation, and 5-year warranty. 51 OD17709/2025-2026:Fire extinguishers (10L dry powder and 4.5kg CO₂) shall be installed as per IS: 2190 with inspection cards. Fire buckets with MS stands, safety posters, and caution notices in Malayalam and English shall be provided for compliance. 52 Providing roofing for DG, Inlet outdoor panels and mechanical screener 53 100.98.1009:Engaging Fitter ( grade 1). 54 15.2.1:Demolishing cement concrete manually / by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in-Charge.Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) 55 2.8.1:Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil 56 50.10.1:Steel work in built up G I tubular ( round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting,fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete 57 50.10.2:Steel work for purlin/single section with G I pipes including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete 58 50.12.1.1:Providing & fixing PVC corrugated roofing sheets of good quality up to any pitch, including fixing with polymer coated J or L hooks, bolts & nuts 8 mm dia G. I plain/ bitumen washers complete but excluding the cost of purlins, rafters, trusses etc. The sheets shall be opaque or translucent, clear or pigmented, textured or smooth as specified. 59 4.3.1:Centering and shuttering including strutting, propping etc. and removal of form work for:Foundations, footings, bases for columns 60 4.1.3:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size) 61 Replacement of leaking flanged pipes inside the inlet well 62 OD17790/2025-2026:Supply, conveyance, and fixing of 300mm double flanged DI K9 pipe, including scaffolding, fabrication if required (cutting, flange welding), and providing necessary fittings, nuts, bolts, rubber gaskets, and insertion rubber sheets for proper and safe installation at site. 63 OD17835/2025-2026:Dismantling existing 300 mm DI pipes carefully using crane/manual handling with all necessary safety measures, and stacking the removed materials within 50 meters as directed by the Engineer-in-Charge 64 Provision forEntry of Trucks from Rear Side of STP 65 15.7.1:Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge.In mud mortar 66 2.6.1:Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil 67 4.1.8:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size) 68 7.1.1:Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand) 69 5.1.3:Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) 70 50.6.1.1:Solid block masonry using pre cast solid blocks ( factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 part 1 of 1979 for foundation and plinth with thickness 20 cm and above in: CM 1:6 ( 1 cement : 6 coarse sand) etc complete 71 50.6.1.2:Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement: 6 coarse sand) etc complete. 72 13.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) 73 13.43.1:Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer 74 13.82.1:Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound) content less than 50 grams/ litre, of approved brand and manufacture including applying additional coats wherever required, to achieve even shade and colour.One coat 75 10.26.3:Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approves steel primer.G.I. pipes 76 13.52.1:Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturers specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work 77 Security room (4m x 3m) at back entrance of STP 78 2.8.1:Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil 79 4.1.8:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size) 80 50.6.1.1:Solid block masonry using pre cast solid blocks ( factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 part 1 of 1979 for foundation and plinth with thickness 20 cm and above in: CM 1:6 ( 1 cement : 6 coarse sand) etc complete 81 5.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete 82 5.1.2:Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size 83 50.6.1.2:Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement: 6 coarse sand) etc complete. 84 5.3:Reinforced cement concrete work in beams, suspended floors, roofs, having slope up to 150 landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (Zone III) : 3 graded stone aggregate 20 mm nominal size). 85 5.9.3:Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform 86 5.9.5:Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers 87 13.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) 88 5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more 89 OD17944/2025-2026:Providing and fixing glazed shutters for doors, windows and clerestory windows using 4mm thick float glass panes including MS grill with suitable spacing and ISI marked M.S pressed butt hinges bright finished of required size with necessary locking arrangements. 90 OD17947/2025-2026:Electrical work including internal lighting, fan, switches, DB, concealed wiring, and one external LED light with pole/bracket for night visibility, complete with connections, fittings, and testing as per direction of Engineer-in-Charge. 91 13.61.1:Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work
Contract Date: Jun 23, 2026 Contract Value : 2.52 Crore
Local Bodies No of Bidders 1
15.
Public Administrative Department #11334347 Price Bid
Tender For Annual Plan-2025-26 Pudur Gp Pro.No: 15 Ward 1-Center No:176 Kinnattukkara Anganawadi Kettidam Nirmmanam-General Civil Work - A.W Nirmanam 2 2.31:Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared 3 2.6.1:Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.All kinds of soil 4 2.8.1:Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil 5 OD99671/2025-2026:DRY RUBBLE MASONRY -Dry rubble without concrete levelling course masonry with good quality blasted rubble includingpacking to compactness. 6 7.1.1:Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand) 7 4.1.8:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) 8 50.6.1.5:Solid block masonry using pre cast solid blocks ( Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 Part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement : 6 coarse sand) etc complete 9 5.1.2:Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size derived from natural sources) 10 5.3:Reinforced cement concrete work in beams, suspended floors, roofs, having slope up to 15°landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (Zone III)derived from natural sources: 3 graded stone aggregate 20 mm nominal sizederived from natural sources). 11 5.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete 12 5.9.3:Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform 13 5.9.5:Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers 14 5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more 15 10.25.2:Item Shifted to Sub head 14 as item 14.73Item Shifted to head 14 as item 14.74Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works 16 13.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) 17 50.13.1:9 mm cement plastering of mix : 1:3 (1 cement : 3 fine sand ) including all cost of materials, labour charges etc complete 18 11.37:Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete 19 13.46.1:Finishing walls with Acrylic Smooth exterior paint of required shade:New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) 20 13.61.1:Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work 21 17.1.1:Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm Sand Cast Iron P or S trap, 10 litter low level white P.V.C.flushing cistern, including flush pipe, manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever require:White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests 22 18.54.1:Providing and fixing PTMT bib cock of approved quality and colour.15 mm nominal bore, 86 mm long, weighing not less than 88 gms 23 50.18.9.9.2:Providing and fixing PVC pipes includes joints of pipes with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in CHarge. 110 mm dia 4 Kg/cm2 24 50.18.8.2.2:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 20 mm pipe 10 Kgf/ cm2 25 50.18.8.3.2:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 25 mm pipe 10kgf /cm2 26 50.18.8.6.2:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 50 mm pipe 6 kgf/cm2 27 17.7B:Providing and fixing wash basin with C.I. brackets, 15 mm PTMT pillar cock, 32 mm PTMT waste coupling of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required. White Vitreous China Flat back wash basin size 550x400 mm with single 15 mm PTMT pillar cock. 28 50.18.9.6.2:Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 50 mm dia 6 Kgf/cm2 29 18.48:Providing and placing on terrace (at all floor levels) polyethylene water storage tank :ISI 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 30 17.10.2.3:Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required:Kitchen sink without drain board470x420 mm bowl depth 178 mm 31 10.26.1:Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approves steel primer.M.S. tube 32 10.25.1:Item Shifted to Sub head 14 as item 14.73Item Shifted to head 14 as item 14.74Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In stringers, treads,landings etc. of stair cases, including use of chequered plate wherever required, all complete 33 50.6.2.2:Solid masonry using pre cast solid blocks (factory made) of size 30x20x15cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level with thickness 15cm in : CM 1:6 ( 1 cement : 6 coarse sand) etc complete 34 11.41.2:Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600 x 600 mm. 35 11.20.4:Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete on 20 mm thick bed of cement mortar 1:4 ( 1 cement : 4 coarse sand).Ordinary cement without any pigment 36 8.31:Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in- Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
17.
Youth Affairs and Sports and Culture #11323145 Technical Bid
Tender For Purchase Of Biomechanical Equipments , Nord Board , It Should Be Portable And Should Have 2 Load Cell Sensors Per Unit With Easy To Attach Hooks Pivoting 360 Degrees Joint Improving Sensor Accuracy It Should Have Knee Position Indicator For Replication Of Test Position In Each Time. Should Have Sample Rate Per Sensor: Upto 400Hz, Capacity Per Sensor: 100 Kg/980-1000N Safe Over Load Per Sensor: 150Kg/1500N, Max Over Load Per Sensor: 200Kg/ 2000N, Resolution: 1N And Sensitivity: 22.0+/-Mv/V. Should Have Rechargeable Battery & Battery Life Should Be100 Active Hours Approx. Should Have Working Temperature Range 5-40®C. (All Weather Proof) Latest Upgradable Software Should Have Both Wired & Wireless Connectivity Connectivity Through Usb (Wired) Bluetooth Low Energy (Ble) For Ipad & Iphone I.E. (Wireless Connectivity) Should Provide 4 Years Warranty On Hardware, Should Be Provided With Latest Upgradable Software And Free Software Updates. Should Have Software Available In Mobile & Laptop (Desktop) Application With Cloud Analytics Platform Applications. Should Have Ability To Collect Data Both Local I.E. Laptop And On Ios Devices. Local Software:- For Data Collection & Data Analysis Locally. Cloud Software:- For Athlete Data Management And Analysis. Local (Desktop /Laptop) Software Should Be Compatible With Windows 10 Desktop Application Ios 13 Or Later Application (Ipad & Iphone). Should Have Ability To Collect Data Of Over 10000 Athletes Or More To Choose With Simple Name Search / Grouping Them. Cloud Analytics Platform For Analysis. Software (Application) Must Give Real Time Feedback Of Testing. License Must Be Valid For 4Years. Cloud Software: - Should Automatically Sync All Data Collected On Local Mobile And Laptop Application When Connected To Internet. O Should Have A Dashboard To See Overview Of Organizations Athletes Data And Different Tiles (Data Indicators) To See Athletes Within And Outside Threshold Zones. Report Section:- Should Have Port Section To Able To Compare Different Groups/Athletes On Longitudinal Data. Should Have Ability To Compare Same Athletes Data Over The Period. Athletes Profile:- Should Have Functionality To Enter Anthropometry (I.E. Upper Body & Lower Body Measurement). Athletes Profile Should Be Auto Sync To Local Application And Flexibility To Move Across Different Groups Or Teams With In Organization And Functionality To Pick Any Athlete From Large Pool (1000 Or More Athlete). • Should Be Able To Setup Different Access To Different People I.E. To Physiotherapist, Sports Scientist And S&C Trainer Within The Organization To Secure Data Access. Api Integration:- Should Have Open-Source Api Code For Integration Into Athlete Management System To Integrate In Ams System. Should Have Software License Valid For 4Years. Wi-Fi Tablet 64Gb, Space Grey-1Year Warranty (As Provided By Oem) - Service By Customer Service Of Oem Only.Hsn:8471. Training For Installation And Demonstration Shall Be Provided At Olympian Balbir Singh Senior International Hockey Stadium, Sector- 63, Mohali, Punjab. , Electromyography (Open) , The System Should Be Supplied With Minimum 16 High Speed Wireless Emg Channel With Built In Imu Sensor. Should Have Analog+ Digital Base Station • Should Have Analogy Output Option To Facilitate Integration With Third Party Hardware And Software Sensor Should Have Fixed Inter Sensor Delay Of 0.5 Milliseconds Or Less Sensors Should Have Fixed Spacing Between Electrodes Preferably Less Than 15 Mm To Avoid Motion Artifacts And Cross-Talk Sensor Contacts Should Be Made Up Of A Metal For Better Contact And Better-Quality Signal Should Be Supplied With A Charging/Transmitting Station That Communicates With Sensors To Get Information On Their Charging, Recording And Signal Strength Sensors, Sensor Skin Interface, Cable, Power Adapter And Accessories Sensors Facilitate Emg And Imu Measurements Emg Data Analysis Software For Stand-Alone Usage With Live Recording Of At Least 32 Channels And Analysis For Both Online And Offline Modes. Trigger Module Package Analog Adapter With Cable For Dynamometer Integration. • Should Have Option For Real Time Data Streaming To Computational Softwares Such As Mat Lab. Mobile Emg Suite For Outdoor Applications Technical Support For The Lifetime Or At Least For A Period Of 05 Years. The System Should Be Supplied With Sensor Docking Unit And Charging System The System Should Be Supplied With Double Sided Adhesive Stickers (At Least 5000) And Double-Sided Adhesive Tape Rolls (At Least 20). The System Should Be Supplied With At Least 2000 Hz Of Sampling Rate Or More Per Sensor. The System Should Have A Baseline Noise < 1 ?V Or Better. The Emg System Should Have +20,000 ? Vemg Input Range Or Better. The System Should Have Software Controlled Digital Filtering, The System Should Have Shielded Cables For Minimal Artifact. The Software Should Allow Video Recording During Emg Data Recording Should Have At Least 8 Hours Of Battery Backup • Should Have Wireless Working Range Of At Least 40M Or More To Capture Data During Various Sport Specific Movements, Should Be Configurable To 32 Channels In Future. The Emg System Should Be Integrated With 3D Motion Analysis, Force Plate, Isokinetic Dynamometer, Instrumented Treadmill, Imu, Eye Tracking, Video Analysis Etc. The Necessary Third-Party Hardware/ Software Should Be Supplied By The Seller For Integration Of Emg With Other Systems. Laptop I7 (Latest Generation) With 32Gb Ram Or More, 2Tb Ssd, At Least 15.6-Inch Screen And Laser Printer With Copy/Scan/Print To Generate And View Report And Additionally A 32-Inch Monitor For Dual Display. Usfda, Iso & Euiec Certificates Or Equivalent. Installation At The Institute And Training To The Users By Experts Training For Installation And Demonstration Shall Be Provided At Olympian Balbir Singh Senior International Hockey Stadium, Sector- 63, Mohali, Punjab. , Timing Gates (Open) , It Should Be A Wireless Speed Gate With 12 Gates And Provision For Increasing Gates Up To 15 Gates/Splits Or More With Split Distance Fully Customizable To Perform Variety Of Testing (Can Have Splits At 1 Meter Or 10 Meters Or Customized Distance). It Should Be Photocell & Reflector System Only (Light Or Laser Based) Considering Flexibility It Offers To Use Variety Of Testing Protocols With Visual Cue (Light System Provide A Cue To The Athlete To Change Direction) I.E. Single Or Dual Feedback Functions For Athletes. It Should Have An Accuracy Of Minimum 1 Hundredth Of A Second (1/1000Th Of A Second) Or Beyond, With A System To Eliminate Errors Caused By Hands, Feet And Other Body Parts, Equipment (To Provide Most Accurate Data) Must Have Error Correction Processing (Ecp) Inside The Timing Unit. Wireless Range: - Should Be Able To Control Gates Wirelessly With A Range Up To 180-200 Meters. It Should Have Functionalities To Provide 6 Options When Using Different Accessories A. Auto Beam Break B. In-Beam C. Reactive D. Start Pad E. Vibration (Reaction Time Measures) F. Rfid Various Accessories Should Be Integrated With Timing Gates Thus Providing Various Testing Possibilities Of Athletes. It Should Integrate With A Jump Mat (Accessories) For Plyometric Training And Explosive Power Measurement With Multiple Jump Testing Option On Jump Mats. Tests & Drills To Be Measured System Must Be Able To Measure- I. Linear (Straight Line Sprints), Shuttles With Customized Split Distance. Ii. Yoyo, Beep Tests (With Custom Customized Time Interval For Endurance Testing) Iii. Planned, Unplanned Change Of Direction For Agility Testing. Iv. Multiple Reactive Movements. V. Reaction Time Measure For Starting Blocks Any Customized Tests/ Drill With All 6 Or More Gates And No Restrictions On Number Of Customized Drills To Provide More Flexibility In Testing. • Mobile/Tablet Applications & Web Application: I. System Should Be Controlled By And Operated By Tablet/Laptop/Smartphone (Mobile Applications: -Should Have Both Ios & Android Mandatory Considering Large Android Phone User Base In India Along With Ios Application) And Ii. Must Have A Cloud Web Application Platform For Tracking Performance Variables Of 1000 Or More Athletes At One Go For Various Testing. Utility Of Mobile Applications: - I. Flexibility To Perform Test: -Mobile/Tablet Applications Should Have Functionality To - A. Pick Any Athlete From Large Pool (1000 Or More Athlete) B. Pick Any Drill Or Test To Be Conducted And Ability To Customize A Test With All 4 Or More Gates. C. To Visually Display Gates On Mobile Screen To Understand How To Perform A Test/Drill. Application To Automatically Detect Setup Of Gates. Ii. It Should Provide Real Time Data Of Performance, Reaction Time, Speed, And Agility. Iii.Single Or Multiple User With Authorized Access Control- Only Authorized Single Or Multiple Users Admins Should Have Access To Operate Application For Data Security And Data Access. Should Automatically Send Data To The Cloud Application Once Connected To Internet. Software License To Be Valid For 3 Years. Utility Of Web Application: - Functionality Of Web Application: - I. Automatically Populate Data Collected By Mobile Applications. Ii. Should Be Able To Compare Single Athlete Data Historically From Different Trials Or Compare Various Athletes For A Test Or A Drill Over Any Time Period. Iii. Should Be Able To Manage Athletes (By Creating Sports Specific Teams) Iv. Should Be Able To Download Data In Pdf, Excel And Ability To Customize These Reports V. Software License To Be Valid For 3 Years. Integration With 3Rd Party Ams System: -Software Should Have Functionality To Integrate Ams In Near Future Automatically, A Software Must Have Api Available For Seam Less Integration Of All/ Selected Data Of Speed Gates Automatically With Number Of World Leading Ams Systems And This Must Be Automated With Few Clicks Only. Rechargeable Battery Based Systems Should Have At Least 8 Hours Backup Or More. The System Should Be Robust Enough To Be Used In Various Weather Conditions. Should Have Height Adjustable Tripod Stands To Accommodate Various Sports Activities And Test Protocols. Should Provide One (1) Ipad Of Desired Specification To Run The Application (With Minimum 1 Year Warranty) Warranty For 2 Years. Training For Installation And Demonstration Shall Be Provided At Olympian Balbir Singh Senior International Hockey Stadium, Sector- 63, Mohali, Punjab. , Kinematic Analysis System (Open) , . Marker-Based And Markerless (Ai Based) Biomechanical System For Two-Dimensional (2D) Analysis Of Gait Analysis Including Walking And Running Activities, Posture And Other Sports Activities. 2. Biomechanical Motion Analysis Software (Pre-Installed In Computer) Within Built Modules For Standing & Sitting Posture Analysis, Walking Gait Analysis & Running Gait Analysis, Compatible With A Suitable Operating System. 3. It Should Allow Measurement Of Joint Angles & Other Data From Sports Specific Activities Like Jump, Squat, Golf, Tennis Etc. 4. It Should Also Have Features For Marker-Less Assessment Of Functional Activities Like Squats And Other Range Of Motions Of The Body During Various Activities. 5. It Should Be Able To Analyze The Anterior, Posterior, Left & Right Lateral Views Of The Subject And Provide The Following Parameters: (A) Walking Gait Analysis: Rear Foot Eversion/Inversion, Lateral Pelvic Drop, Knee Flexion/Extension, Hip Flexion / Extension, Ankle Plantar /Dorsiflexion, Knee Ab /Adduction, Stance Phase % - Swing Phase %, Step Length, Stride Length, Gait Velocity Etc. Data To Be Measured For Both Left And Right Extremities (B) Running Gait Analysis: Rear-Foot Eversion/Inversion, Lateral Pelvic Drop, Trunk Side Bending, Crossover Gait, Knee Flexion, Leg Inclination Angle, Knee Toe-Alignment, Hip Extension, Ankle Plantar Flexion, Net Vertical Oscillation Of Center Of Mass, Knee Ab /Adduction, Ground Contact Time Etc.. Data To Be Measured For Both Left And Right Extremities. (C) Posture Analysis: Major Postural Deviations Like Rear-Foot Eversion /Inversion, Forward Head Posture, Shoulder Protraction, Genu Recurvate, Lateral Head Tilt, Shoulder Level, Lateral Pelvic Drop, Lateral Trunk Sway, Q Angle (D) Sitting Posture Angle: Viewing Angle, Viewing Distance, Forward Head Angle, Elbow Flexion/Extension, Trunk Flexion/Extension, Knee Flexion/Extension, Hip Knee Alignment (E) Bike Fitting: Major Parameters Like Ankle Plantar Flexion /Dorsiflexion, Knee Flexion/ Extension, Hip Flexion, Hip Vertical Travel, Back Angle, Elbow Angle, Armpit Angle, Kops, Knee Tracking. (F) Squat Analysis: Major Parameters Like Descent: Ascent Ratio, Squat Stance Width, Heel Rise Detection, Head Tilt, Shoulder Tilt, Lateral Trunk Tilt, Pelvic Tilt, Frontal Knee Alignment, Knee-Toe Alignment, Trunk Inclination (Sagittal Plane), Tibia Inclination (Sagittal Plane), Knee Flexion (Depth Of Squat). 6. It Should Be Able To Generate Organized Reports With Following Features: (A) Data Represented In Tabular & Photographic Form (B) In Built Reference Ranges For Every Parameter Measured. (C) All Data Lying Outside Reference Ranges To Be Highlighted In Bold (D) Automatic Documentation Of All Observations And Abnormal Biomechanics In Form Of Notes (With Choice Of Hindi Or English Language If Needed). (E) Automatic Summary Of All Reports Should Be Generated. 7. It Should Have An Option To Export All Data To Excel Sheets 8. It Should Have An Inbuilt Comparison Feature That Generates Post Comparison Reports To Monitor Changes In Patients Posture And Gait. 9. It Should Have An In-Built Data Base Feature For Storing Analysis Data. 10. Software Should Use Ai (Artificial Intelligence) Models To Provide Markerless Analysis. 11. Software Should Also Use Ai (Artificial Intelligence) Models To Aid In Marker Digitization In Case Of Marker Based Analysis. 12. Motion Capture Cameras Supporting Video Capture In Outdoor Conditions (Running Track) As Well As Indoor Conditions (Floor, Walkway & Treadmill). Camera Specifications: (A) Wired Cameras-04 In Numbers With Capture Rate Up To 60 Fps. (B) Wirelesscameras-02 In Numbers With Capture Rate Up To 240 Fps. 12. The System Should Have Data Transfer Cables And Connector Cables For Camera Along With Tripods For Mounting Of Cameras. 13. Marker Set (With Marker Placement Guide) For Standing Posture, Walking Gait Analysis, Running Gait Analysis And Bike Fitting With Reusable Markers Or Disposable Markers (Adequate In Number For Conducting At Least 100 Tests Each) 14. Compression Clothing For Lower Body & Upper Body Should Be Provided. 15. Quality Clearance For Cameras: Usfcc/ Euce/ Isobis (Either Of The Certifications). 16. Should Be Safe And Non-Invasive, Easy To Use. 17. Carry Case/Bag For Storing And Carrying All Hardware Equipment To Be Provided. 18. In Person Training, Virtual Assistance & Technical Support For System Operation. 19. The Biomechanical Analysis Software Should Have License Validity Along With All Updates And Bug Fixes For A Minimum Period Of 10 Years. 20. The System Should Come With A Hardware Warranty Of 3 Years. 21. Computer Specifications: Intel 5Th Generation Processor Or Better, 8 Gb Ram, Windows 10/11, At Least 2 Usb Ports. , Foot Pressure Analysis System (Open) , 1. The Number Of Sensors Should Be Between 2900 To 4000. 2. The Active Sensor Area Should Be At Least 375 X 375 Mm. 3. The System Should Be Able To Perform Static (Standing) & Dynamic (Walking) Assessment And Provide Data Of Foot Pressure Distribution During These Activities. 4. It Should Also Have Capability To Perform Sway (Balance) Assessments During Eyes Open And Closed Conditions. 5. System Should Be Able To Generate Automated Remarks For Symmetries Of Pressure Distribution. 6. System Should Be Able To Identify Change In Pressures With & Without Footwear /In Soles. 7. Option Of Comparing Patients Data Over Time Should Be Provided. 8. Option Of Exporting Report Data In Excel Format Should Be Available. 9. Facility To Email Report With Patient Information Should Be Provided. 10. System Should Have Wired Operation. 11. System Should Work Without The Internet. 12. Should Have Operating Temperature Range Between 5° C To 50°C 13. Frequency Range Should Be At Least 100 Hz 14. Pressure Range Should Be Between 1 To 150 Psi 15. Sensor Resolution Should Be Equal To Or More Than 2 Per Cm^2 16. Sensor Technology Should Be Piezo Resistive 17. Should Be Supplied With A Padded Carry Bag. 18. Should Be Supplied With 2 Additional Dummy Platforms 19. System Should Not Need A Separate Electrical Supply And Should Draw Power From The Computer. 20. The Complete System Should Have 3-Year Hardware Warranty Period Along With Software Updates And Tech Support. Training For Installation And Demonstration Shall Be Provided At Olympian Balbir Singh Senior International Hockey Stadium, Sector- 63, Mohali, Punjab. Please Enable Macros To View Boq Information
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
18.
Tourism #11320518 Technical Bid
Tender For Tourism Development Work Of Shri Ramjanaki Temple, Kotawari In Shahjahanpur District.-1 Earth Work In Excavation By Mechanical Means (Hydraulic Excavator)/ Manual Means Over Areas (Exceeding 30 Cm In Depth, 1.5 M In Width As Well As 10 Sqm On Plan) Including Getting Out And Disposal Of Excavated Earth Lead Upto 50 M And Lift Upto 1.5 M, As Directed By Engineer-Incharge. All Kinds Of Soil Dsr-2.6.1 170.25 Cum 133.12 127.80 21757.52 In All Kind Of Soil Upto 1.5M To 3.0M. Depth 2.6.1+2.26.1 18.74 Cum 228.22 219.09 4106.24 In All Kind Of Soil Upto 3.0M To 4.5M. Depth 2.6.1+(2.26.1* 2) 6.37 Cum 323.31 310.38 1977.88 2 Excavation Of Foundation In Ordinary Soil (Loam Clay Or Sand) Including Lift Upto 1.50 Meter And Lead Upto 30 Meter And Including Filling, Watering And Ramming Of Excavated Earth Into The Trenches Or Into The Space Between The Building And Sides Of Foundation Trenches Or Into The Plinth And Removal And Disposal Of Sur-Plus Earth As Directed By The Engineer Incharge Up To A Distance Of 30 Meters From The Foundation Trenches. Dsr-2.1.1 35.61 Cum 97.38 93.49 3329.14 3 Filling Available Excavated Earth (Excluding Rock) In Trenches, Plinth, Sides Of Foundations Etc. In Layers Not Exceeding 20Cm In Depth, Consolidating Each Deposited Layer By Ramming And Watering, Lead Up To 50 And For All Lift. Dsr-2.25 8.70 Cum 147.00 141.12 1227.84 4 Excavating, Supplying And Filling Of Local Earth (Including Royalty) By Mechanical Transport Upto A Lead Of 5Km Also Including Ramming And Watering Of The Earth In Layers Not Exceeding 20 Cm In Trenches, Plinth, Sides Of Foundation Etc. Complete Dsr-2.25(A) 55.60 Cum 525.36 504.34 28041.40 5 Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level : 1:4:8 (1 Cement : 4 Coarse Sand (Zone-Iii) Derived From Natural Sources : 8 Graded Stone Aggregate 40 Mm Nominal Size Derived From Natural Sources) Dsr-4.1.8 70.78 Cum 5108.83 4904.47 347162.56 6 Supplying And Filling In Plinth With Sand Under Floors, Including Watering, Ramming, Consolidating And Dressing Complete. Dsr-2.27 26.31 Cum 1592.76 1529.05 40229.27 7 Diluting And Injecting Chemical Emulsion For Postonstructional Anti-Termite Treatment (Excluding The Cost Of Chemical Emulsion) : Treatment Of Soil Under Existing Floors Using Chemical Emulsion @ One Litre Per Hole, 300 Mm Apart Including Drilling 12 Mm Diameter Holes And Plugging With Cement Mortar 1 :2 (1 Cement : 2 Coarse Sand) To Match The Existing Floor: With Chlorpyriphos/Lindane E.C. 20% With 1% Concentration Dsr-2.35.3.1 194.47 Sqm 232.53 223.23 43411.24 8 Reinforced Cement Concrete Work In Beams, Suspended Floors, Roofs Having Slope Up To 15° Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Window Sills, Staircases And Spiral Stair Cases Above Plinth Level Up To Floor Five Level, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement With 1:1.5:3 (1 Cement : 1.5 Coarse Sand(Zone-Iii) Derived From Natural Sources : 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources). Dsr-5.3 82.66 Cum 8628.83 8283.68 684729.10 9 Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement - All Work Up To Plinth Level : 1:1.5:3 (1 Cement : 1.5 Coarse Sand (Zone-Iii) Derived From Natural Sources : 3 Graded Stone Aggregate 20 Mm Nominal Size De Rived From Natural Sources) Footing Dsr-5.1.2 21.98 Cum 6784.08 6512.72 143149.60 10 Reinforced Cement Concrete Work In Walls (Any Thickness), Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc. Above Plinth Level Up To Floor Five Level, Excluding Cost Of Centering, Shuttering, Finishing And Reinforcement : 1:1.5:3 (1 Cement : 1.5 Coarse Sand(Zone-Iii) Derived From Natural Sources : 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources) Dsr-5.2.2 22.97 Cum 8139.44 7813.86 179484.39 Abstract Of Cost Delhi Schedule Of Rate Effective From 12/07/2023 X (0.735X106/107X1.03) Has Been Followed. Proposed Tourism Development Of Ramjanki Temple At Kotawari, Tilhar, Sahjahanpur, U.P. 11 Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For Lintels, Beams, Plinth Beams, Girders, Bressumers And Cantilevers Dsr-5.9.5 257.49 Sqm 552.28 530.19 136518.66 12 Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For Suspended Floors, Roofs, Landings, Balconies And Access Platform Dsr-5.9.3 407.10 Sqm 695.41 667.60 271778.96 13 Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For Foundations, Footings, Bases Of Columns, Etc. For Mass Concrete Dsr-5.9.1 63.96 Sqm 294.10 282.34 18058.37 14 Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For Columns, Pillars, Piers, Abutments, Posts And Struts Dsr-5.9.6 208.86 Sqm 720.95 692.11 144554.66 15 Brick Work With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 In Foundation And Plinth In: Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) Dsr-6.1.1 16.84 Cum 5527.80 5306.69 89341.45 16 Brick Work With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 In Foundation And Plinth In: Cement Mortar 1:6 (1 Cement : 6 Coarse Sand) Dsr-6.1.2 51.30 Cum 5349.01 5135.05 263427.92 17 Providing And Laying Damp-Proof Course 50Mm Thick With Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand (Zone-Iii) Derived From Natural Sources : 4 Graded Stone Aggregate 20Mm Nominal Size Derived From Natural Sources). Dsr-4.11 2.14 Sqm 371.80 356.93 763.83 18 Providing & Applying A Coat Of Residual Petroleum Bitumen Of Grade Of Vg-10 Of Approved Quality Using 1.7Kg Per Square Metre On Damp Proof Course After Cleaning The Surface With Brushes And Finally With A Piece Of Cloth Lightly Soaked In Kerosene Oil. Dsr-4.13 44.55 Sqm 109.61 105.22 4687.75 19 Brick Work With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 In Superstructure Above Plinth Level Up To Floor V Level In All Shapes And Sizes In : Cement Mortar 1:6 (1 Cement : 6 Coarse Sand) Dsr-6.4.2 80.04 Cum 6829.23 6556.06 524747.32 20 Half Brick Masonry With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 In Superstructure Above Plinth Level Up To Floor V Level. Cement Mortar 1:4 (1 Cement :4 Coarse Sand) Dsr-6.13.2 60.18 Sqm 842.82 809.11 48692.17 21 Steel Reinforcement For R.C.C. Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Above Plinth Level. Thermo-Mechanically Treated Bars Of Grade Fe-500D Or More Dsr-5.22A.6 186.64 Qtl 8088.48 7764.94 1449250.34 22 15 Mm Cement Plaster On Plinth Side Of Single Or Half Brick Wall Of Mix : 1:4 (1 Cement: 4 Coarse Sand) Dsr-13.5.1 65.74 Sqm 308.80 296.45 19488.62 23 15 Mm Cement Plaster On Rough Side Of Single Or Half Brick Wall Of Mix: 1:6 (1 Cement: 6 Coarse Sand) Dsr-13.5.2 252.10 Sqm 296.50 284.64 71758.35 24 12 Mm Cement Plaster Of Mix : 1:6 (1 Cement: 6 Coarse Sand) Dsr-13.4.2 609.85 Sqm 257.73 247.42 150888.63 25 Add For Plaster Drip Course/ Groove In Plastered Surface Or Moulding To R.C.C. Projections. Dsr-5.30 315.01 Rm 58.80 56.45 17781.09 26 Cement Concrete Flooring 1:2:4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate) Finished With A Floating Coat Of Neat Cement, Including Cement Slurry, But Excluding The Cost Of Nosing Of Steps Etc. Complete. 40 Mm Thick With 20 Mm Nominal Size Stone Aggregate Dsr-11.3.1 29.40 Sqm 460.63 442.21 13000.95 27 Cement Plaster Skirting Up To 30 Cm Height, With Cement Mortar 1:3 (1 Cement : 3 Coarse Sand), Finished With A Floating Coat Of Neat Cement.18 Mm Thick Dsr-11.6.1 3.35 Sqm 496.52 476.66 1596.81 26 Providing And Laying Vitrified Floor Tiles In Different Sizes (Thickness To Be Specified By The Manufacturer) With Water Absorption Less Than 0.08% And Conforming To Is: 15622, Of Approved Make, In All Colours And Shades, Laid On 20 Mm Thick Cement Mortar 1:4 (1 Cement : 4 Coarse Sand), Jointing With Grey Cement Slurry @ 3.3 Kg/ Sqm Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete. Size Of Tile 600X600 Mm Dsr-11.41.2 137.75 Sqm 1165.05 1118.45 154065.99 27 Providing And Laying Vitrified Tiles In Different Sizes (Thickness To Be Specified By Manufacturer), With Water Absorption Less Than 0.08 % And Conforming To |.S. 15622, Of Approved Make, In All Colours & Shade, In Skirting, Riser Of Steps, Over 12 Mm Thick Bed Of Cement Mortar 1:3 (1 Cement: 3 Coarse Sand), Jointing With Grey Cement Slurry @ 3.3 Kg/ Sqm Including Grouting The Joint With White Cement & Matching Pigments Etc. Complete. Size Of Tile 600X600 Mm Dsr-11.46.2 10.17 Sqm 1217.25 1168.56 11884.22 28 Providing And Fixing 1St Quality Ceramic Glazed Floor Tiles Conforming To Is : 15622 (Thickness To Be Specified By The Manufacturer ) Of Approved Make In All Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Engineer-In-Charge In Skirting, Risers Of Steps And Dados Over 12 Mm Thick Bed Of Cement Mortar 1:3 (1 Cement: 3 Coarse Sand) And Jointing With Grey Cement Slurry @ 3.3Kg Per Sqm Including Pointing In White Cement Mixed With Pigment Of Matching Shade Complete. Dsr-11.37A 148.53 Sqm 812.00 779.52 115781.77 29 Providing And Laying Rectified Glazed Ceramic Floor Tiles Of Size 300X300 Mm Or More (Thickness To Be Specified By The Manufacturer), Of 1St Quality Conforming To Is : 15622, Of Approved Make, In Colours White, Ivory, Grey, Fume Red Brown, Laid On 20 Mm Thick Cement Mortar 1:4 (1 Cement: 4 Coarse Sand), Jointing With Grey Cement Slurry @ 3.3Kg/ Sqm Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete. Dsr-11.39 4.40 Sqm 997.47 957.57 4213.30 30 Chequerred Precast Cement Concrete Tiles 22 Mm Thick In Footpath & Courtyard, Jointed With Neat Cement Slurry Mixed With Pigment To Match The Shade Of Tiles, Including Rubbing And Cleaning Etc. Complete, On 20 Mm Thick Bed Of Cement Mortar 1:4 (1 Cement: 4 Coarse Sand). Ordinary Cement Without Any Pigment 11.20.4 6.12 Sqm 792.24 760.55 4654.54 31 Providing And Fixing Panelled Or Panelled And Glazed Shutters For Doors,Windows And Clerestory Windows, Fixing With Butt Hinges Of Required Size With Necessary Screws, Excluding Panelling Which Will Be Paid For Separately, All Complete As Per Direction Of Engineer-In-Charge. (Note: Butt Hinges And Necessary Screws Shall Be Paid Separately) 35 Mm Thick Dsr-9.5.1.1 6.30 Sqm 3083.86 2960.50 18651.18 32 Providing And Fixing Panelled Or Panelled And Glazed Shutters For Doors,Windows And Clerestory Windows, Fixing With Butt Hinges Of Required Size With Necessary Screws, Excluding Panelling Which Will Be Paid For Separately, All Complete As Per Direction Of Engineer-In-Charge. (Note: Butt Hinges And Necessary Screws Shall Be Paid Separately) 30 Mm Thick Dsr-9.5.1.2 83.22 Sqm 2810.38 2697.97 224524.67 33 Providing And Fixing Isi Marked Flush Door Shutters Conforming To Is : 2202 (Part I) Non-Decorative Type, Core Of Block Board Construction With Frame Of 1St Class Hard Wood And Well Matched Commercial 3 Ply Veneering With Vertical Grains Or Cross Bands And Face Veneers On Both Faces Of Shutters: 35 Mm Thick Including Isi Marked Stainless Steel Butt Hinges With Necessary Screws Dsr-9.21.1 15.33 Sqm 1794.43 1722.65 26408.23 34 Providing 40X5 Mm Flat Iron Hold Fast 40 Cm Long Including Fixing To Frame With 10 Mm Diameter Bolts, Nuts And Wooden Plugs And Embedding In Cement Concrete Block 30X10X15Cm 1:3:6 Mix (1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20Mm Nominal Size). Dsr-9.53 128.00 Nos 171.63 164.77 21090.11 35 Providing And Fixing M.S. Grills Of Required Pattern In Frames Of Windows Etc. With M.S. Flats, Square Or Round Bars Etc. Including Priming Coat With Approved Steel Primer All Complete. Fixed To Steel Windows By Welding Dsr-9.48.1 937.05 Kg 164.32 157.75 147816.54 36 Providing And Fixing T-Iron Frames For Doors, Windows And Ventilators Of Mild Steel Tee-Sections, Joints Mitred And Welded, Including Fixing Of Necessary Butt Hinges And Screws And Applying A Priming Coat Of Approved Steel Primer. Fixing With 15X3 Mm Lugs 10 Cm Long Embedded In Cement Concrete Block 15X10X10 Cm Of C.C. 1:3:6 (1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20 Mm Nominal Size). Dsr-10.13.1 100.80 Kg 106.27 102.02 10283.67 37 Providing And Fixing Angle Iron Frames For Doors, Windows And Ventilators Of Mild Steel Angle Sections Of Size 35X35X5 Mm, Joints Mitred And Welded By Angle Iron 35X35X5 Mm Or 35X 5 Mm Flat Pieces To The Existing T-Iron Frame Or To The Wall With Dash Fastener, Including Fixing Of Necessary Butt Hinges And Screws And Applying A Priming Coat Of Approved Steel Primer, All Complete As Per The Direction Of Engineer-In-Charge. Dsr-10.31 125.00 Kg 97.87 93.96 11744.60 38 Providing And Fixing Stainless Steel ( Grade 304) Railing Made Of Hollow Tubes, Channels, Plates Etc., Including Welding, Grinding, Buffing, Polishing And Making Curvature (Wherever Required) And Fitting The Same With Necessary Stainless Steel Nuts And Bolts Complete, I/C Fixing The Railing With Necessary Accessories & Stainless Steel Dash Fasteners , Stainless Steel Bolts Etc., Of Required Size, On The Top Of The Floor Or The Side Of Waist Slab With Suitable Arrangement As Per Approval Of Engineer-Incharge, (For Payment Purpose Only Weight Of Stainless Steel Members Shall Be Considered Excluding Fixing Accessories Such As Nuts, Bolts, Fasteners Etc.). Dsr 10.28 133.33 Kg 579.28 556.11 74146.05 39 Providing Wood Work In Frames Of Doors, Windows, Clerestory Windows And Other Frames, Wrought Framed And Fixed In Position With Hold Fast Lugs Or With Dash Fasteners Of Required Dia & Length (Hold Fast Lugs Or Dash Fastener Shall Be Paid For Separately).(Sal Wood) Dsr-9.1.2 1.61 Cum 87387.28 83891.79 135065.79 40 Fixing Of Door, Windows/Ventilators Chaukhats In Position. (A) Door Chaukhats Above 1.5 Sqm To 5.0Sqm Mr 19.00 Nos 150.00 144.00 2736.00 (B) Window Chaukhats Above 1.5 Sqm 12.00 Nos 100.00 96.00 1152.00 (C) Ventilator Chaukhats 7.00 Nos 50.00 48.00 336.00 41 Finishing Walls With Premium Acrylic Smooth Exterior Paint With Silicone Additives Of Required Shade: New Work (Two Or More Coats Applied @ 1.43 Ltr/10 Sqm Over And Including Priming Coat Of Exterior Primer Applied @ 2.20 Kg/10 Sqm) Dsr-13.47.1 407.00 Sqm 128.32 123.19 50137.46 42 Distempering With Oil Bound Washable Distemper Of Approved Brand And Manufacture To Give An Even Shade : New Work (Two Or More Coats) Over And Including Water Thinnable Priming Coat With Cement Primer Dsr-13.41.1 434.15 Sqm 139.23 133.66 58030.01 43 Providing And Applying White Cement Based Putty Of Average Thickness 1 Mm, Of Approved Brand And Manufacturer, Over The Plastered Wall Surface To Prepare The Surface Even And Smooth Complete. Dsr-13.80 841.15 Sqm 117.03 112.35 94505.07 44 Providing And Fixing Isi Marked Oxidised M.S. Sliding Door Bolts With Nuts And Screws Etc. Complete :250X16 Mm Dsr-9.62.2 11.00 Nos 145.27 139.46 1534.05 45 Providing And Fixing Isi Marked Oxidised M.S. Tower Bolt Black Finish, (Barrel Type) With Necessary Screws Etc. Complete : 250X10 Mm Dsr-9.63.1 21.00 Nos 62.92 60.41 1268.53 200X10 Mm Dsr-9.63.2 65.00 Nos 52.05 49.97 3247.81 46 Providing And Fixing Isi Marked Oxidised M.S. Handles Conforming To Is:4992 With Necessary Screws Etc. Complete :100 Mm Dsr-9.66.2 54.00 Nos 24.41 23.44 1265.50 47 Providing And Fixing Bright Finished Brass Hanging Type Floor Door Stopper With Necessary Screws, Etc. Complete Dsr-9.82 1.00 Nos 91.23 87.59 87.59 48 Providing And Laying Integral Cement Based Water Proofing Treatment Including Preparation Of Surface As Required For Treatment Of Roofs, Balconies, Terraces Etc Consisting Of Following Operations: (A) Applying A Slurry Coat Of Neat Cement Using 2.75 Kg/Sqm Of Cement Admixed With Water Proofing Compound Conforming To Is. 2645 And Approved By Engineer-In-Charge Over The Rcc Slab Including Adjoining Walls Upto 300 Mm Height Including Cleaning The Surface Before Treatment. (B) Laying Brick Bats With Mortar Using Broken Bricks/Brick Bats 25 Mm To 115 Mm Size With 50% Of Cement Mortar 1:5 (1 Cement : 5 Coarse Sand) Admixed With Water Proofing Compound Conforming To Is : 2645 And Approved By Engineerin- Charge Over 20 Mm Thick Layer Of Cement Mortar Of Mix 1:5 (1 Cement :5 Coarse Sand ) Admixed With Water Proofing Compound Conforming To Is : 2645 And Approved By Engineerin- Charge To Required Slope And Treating Similarly The Adjoining Walls Upto 300 Mm Height Including Rounding Of Junctions Of Walls And Slabs. (C) After Two Days Of Proper Curing Applying A Second Coat Of Cement Slurry Using 2.75 Kg/ Sqm Of Cement Admixed With Water Proofing Compound Conforming To Is : 2645 And Approved By Engineer-In-Charge. (D) Finishing The Surface With 20 Mm Thick Jointless Cement Mortar Of Mix 1:4 (1 Cement :4 Coarse Sand) Admixed With Water Proofing Compound Conforming To Is : 2645 And Approved By Engineer-In-Charge Including Laying Glass Fibre Cloth Of Approved Quality In Top Layer Of Plaster And Finally Finishing The Surface With Trowel With Neat Cement Slurry And Making Pattern Of 300X300 Mm Square 3 Mm Deep. (E) The Whole Terrace So Finished Shall Be Flooded With Water For A Minimum Period Of Two Weeks For Curing And For Final Test.“All Above Operations To Be Done In Order And As Directed And Specified By The Engineer-In-Charge : With Average Thickness Of 120 Mm And Minimum Thickness At Khurra As 65 Mm Dsr-22.7.1 198.55 Sqm 1263.41 1212.87 240815.58 49 Finishing With Deluxe Multi Surface Paint System For Interiors And Exteriors Using Primer As Per Manufacturers Specifications : Painting Steel Work With Deluxe Multi Surface Paint To Give An Even Shade. Two Or More Coat Applied @ 0.90 Ltr/ 10 Sqm Over An Under Coat Of Primer Applied @ 0.80 Ltr/ 10 Sqm Of Approved Brand And Manufacture Dsr-13.48.3 144.65 Sqm 128.02 122.90 17777.47 50 Finishing With Deluxe Multi Surface Paint System For Interiors And Exteriors Using Primer As Per Manufacturers Specifications : Painting Wood Work With Deluxe Multi Surface Paint Of Required Shade. Two Or More Coat Applied @ 0.90 Ltr/10 Sqm Over An Under Coat Of Primer Applied @0.75 Ltr/10 Sqm Of Approved Brand And Manufacture Dsr-13.48.2 209.70 Sqm 132.18 126.90 26610.03 51 Providing & Fixing Panes Of Glass With Equal Or Equivalent I.S.I Marked Quality Putty. Brads And Springs And Including Supply Of All Materials And Labour Etc Complete . 3.8 To 4.7 Mm Thick Dsr-10.30.1 44.76 Sqm 805.96 773.72 34631.80 52 Supply And Fixing Of Drop Down Rail / Grab Bars Mr 4.00 Nos. 4400.00 4224.00 16896.00 53 Providing, Driving With Hydraulic Piling Rigs With Power Units And Installing Driven Cast-In-Situ Reinforced Cement Concrete Piles Of Grade M-25 Of Specified Diameter And Length Below The Pile Cap, To Carry Safe Working Load Not Less Than Specified, Excluding The Cost Of Steel Reinforcement But Including The Cost Of Shoe And The Length Of Pile To Be Embedded In The Pile Cap Etc. All Complete. (Length Of Pile For Payment Shall Be Measured From Top Of Shoe To The Bottom Of Pile Cap) : 400 Mm Dia Piles Dsr-20.1.1 48.00 Rm 2075.18 1992.17 95624.30 54 Stone Work (Machine Cut Edges) For Wall Lining Etc. (Veneer Work) Upto 10 Metre Height, Backing Filled With A Grout Of Average 12 Mm Thick Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) Including Pointing In White Cement Mortar 1:2 (1 White Cement : 2 Stone Dust) With An Admixture Of Pigment Matching The Stone Shade : (To Be Secured To The Backing And The Sides By Means Of Cramps And Pins Which Shall Be Paid For Separately) : 30 Mm Thick Dsr-8.14.1.5 50.74 Sqm 3971.79 3812.92 193478.98 55 Stone Work In Plain Ashlar In Super Structure Upto Floor Five Level In Cement Mortar 1:6 (1 Cement : 6 Coarse Sand) Including Pointing With Cement Mortar 1:2 (1 White Cement : 2 Stone Dust) With An Admixture Of Pigment Matching The Stone Shade Both Face Dressed Red Sand Stone Dsr-7.12.1.1 3.56 Cum 51218.78 49170.03 175241.97 56 Extra For Stone Work Ashlar Sunk Or Moulded Or Sunk And Moulded Or Carved In : Triangular Or Square Or Rectangular Pillars Dsr-7.21.1 3.56 Cum 2834.15 2720.79 9696.89 57 Providing And Fixing Stainless Steel Cramps Of Required Size And Shape For Anchoring Stone Wall Lining To The Backing Or Securing Adjacent Stones In Stone Wall Lining In Cement Mortar 1:2 (1 Cement : 2 Coarse Sand), Including Making The Necessary Chases In Stone And Holes In Walls Wherever Required. Dsr-8.15 99.58 Kg. 535.78 514.35 51219.04 58 Stone Work (Machine Cut Edges) For Wall Lining Etc. (Veneer Work) Upto 10 Metre Height, Backing Filled With A Grout Of Average 12 Mm Thick Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) Including Pointing In White Cement Mortar 1:2 (1 White Cement : 2 Stone Dust) With An Admixture Of Pigment Matching The Stone Shade : (To Be Secured To The Backing And The Sides By Means Of Cramps And Pins Which Shall Be Paid For Separately) :Red Sand Stone - Exposed Face Machine Cut And Table Rubbed With Rough Backing. 50Mm Dsr 8.14.1.3 37.80 Sqm. 4342.28 4168.59 157572.62 59 Providing And Fixing Copper Pins 7.5 Cm Long 6 Mm Diameter For Securing Adjacent Stones In Stone Wall Lining In Cement Mortar 1:2 (1 Cement : 2 Coarse Sand), Including Making The Necessary Chases. Dsr 8.16 30.00 Nos. 32.92 31.61 948.21 60 Providing And Fixing Stone Jali 40 Mm Thick Throughout In Cement Mortar 1:3 (1 Cement : 3 Coarse Sand), Including Pointing In White Cement Mortar 1:2 (1 White Cement : 2 Stone Dust) With An Admixture Of Pigment, Matching The Stone Shade, Jali Slab Without Any Chamfers Etc. Red Sand Stone Dsr 7.33.1 4.50 Sqm. 11198.29 10750.35 48376.59 61 Stone Work, Plain In Copings, Cornices, String Courses And Plinth Courses, Upto 75 Mm Thick In Cement Mortar 1:6 (1 Cement : 6 Coarse Sand), Including Pointing With White Cement Mortar 1:2 (1 White Cement : 2 Stone Dust) With An Admixture Of Pigment Matching The Stone Shade.: Red Sand Stone Dsr 7.32.1 0.47 Cum. 70303.46 67491.32 31720.92 62 Carving & Engraving Work On Red Sand Stone (Labour Only) M.R. 9.73 Sqm. 15615.00 14990.40 145856.59 63 Manufacturing, Supplying And Fixing Retro Reflective Overhead Signage Boards Made Up Of 2 Mm Thick Aluminium Sheet, Face To Be Fully Covered With High Intensity And Encapsulated Lens Type Heat Activated Retro Reflective Sheeting Conforming To Type - Iii Of Astm-D-4956-01 As Approved By Engineer-In-Charge, Letters, Borders Etc. As Per Irc : 67-2001 In Silver White With Blue Colour Back Ground And With High Intensity Grade, Pasted On Substrate By Pressure Sensitive Adhesive Backing Which Shall Be Activated By Applying Pressure Conforming To Class Ii Of Astm-D-4956-01 And Fixing The Same To The Plate Of Structural Frame Work By Means Of Suitable Sized Aluminium Alloys, Rivets Or Bolts & Nuts @ 300 Mm Centre To Centre All Along The Periphery As Well As In Two Vertical Rows Along With Theft Resistant Measures, Including The Cost Of Painting With Two Or More Coats Of Epoxy Paint In Grey Colour On The Back Side Of Aluminium Sheet Including Appropriate Priming Coat. The Rate Includes The Cost Of Rounding Off The Corners, Lowering Down The Structural Frame Work From The Gantry, Fixing And Erecting The Same In Position All Complete As Per Drawings, Specification And Direction Of The Engineerincharge.( Structural Frame Work Including M.S. Plate To Be Provided Separately. Rectangular Area Of The Sheet Only Shall Be Measured For Payment). Overhead Informatory Road Signage Dsr 16.60.1 8.64 Sqm. 4409.78 4233.39 36576.45 64 Providing And Fixing 18 Mm Thick Gang Saw Cut, Mirror Polished, Premoulded And Prepolished, Machine Cut For Kitchen Platforms, Vanity Counters, Window Sills, Facias And Similar Locations Of Required Size, Approved Shade, Colour And Texture Laid Over 20 Mm Thick Base Cement Mortar 1:4 (1 Cement : 4 Coarse Sand), Joints Treated With White Cement, Mixed With Matching Pigment, Epoxy Touch Ups, Including Rubbing, Curing, Moulding And Polishing To Edges To Give High Gloss Finish Etc. Complete At All Levels. Dsr 8.2.2.2 34.45 Sqm 3852.10 3698.01 127396.50 65 Making Plinth Protection 50 Mm Thick Of Cement Concrete 1:3:6 (1 Cement : 3 Coarse Sand (Zone-Iii) Derived From Natural Sources : 6 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources) Over 75 Mm Thick Bed Of Dry Brick Ballast 40 Mm Nominal Size, Well Rammed And Consolidated And Grouted With Fine Sand, Including Necessary Excavation, Levelling & Dressing & Finishing The Top Smooth. Dsr-4.17 6.00 Sqm 561.96 539.48 3236.87 66 Providing And Laying Factory Made Chamfered Edge Cement Concrete Paver Blocks In Footpath, Parks, Lawns, Drive Ways Or Light Traffic Parking Etc, Of Required Strength, Thickness & Size/ Shape, Made By Table Vibratory Method Using Pu Mould, Laid In Required Colour & Pattern Over 50 Mm Thick Compacted Bed Of Sand, Compacting And Proper Embedding/Laying Of Inter Locking Paver Blocks Into The Sand Bedding Layer Through Vibratory Compaction By Using Plate Vibrator, Filling The Joints With Sand And Cutting Of Paver Blocks As Per Required Size And Pattern, Finishing And Sweeping Extra Sand. Complete All As Per Direction Of Engineer-In-Charge.80 Mm Thick C.C. Paver Block Of M-35 Grade With Approved Colour Design And Pattern Dsr-16.91.2 207.07 Sqm 818.60 785.85 162723.31 1 Providing And Fixing Water Closet Squatting Pan (Indian Type W.C. Pan) With 100Mm Sand Cast Iron P Or S Trap, 10 Litre Low Level White P.V.C. Flushing Cistern With Manually Controlled Device (Handle Lever) Conforming To Is : 7231, With All Fitting And Fixtures Completed Including Cutting And Making Good The Walls And Floors Wherever Required.White Vitreous China Orissa Pattern W.C. Pan Of Size 580X440 Mm With Integral Type Foot Rests 17.1.1 2.00 Nos. 5075.38 4872.36 9744.73 2 Providing And Fixing White Vitreous China Pedestal Type Water Closet (European Type W.C. Pan) With Isi Marked White Solid Plastic Seat And Lid, 10 Litre Low Level White P.V.C. Flushing Cistern With Manually Controlled Device (Handle Lever), Conforming To Is : 7231, With All Fittings And Fixtures Complete Including Cutting And Making Good The Walls And Floors Wherever Required. W.C. Pan With Isi Marked White Solid Plastic Seat And Lid 17.2.1 3.00 Nos. 4886.50 4691.04 14073.11 3 Providing And Fixing Wash Basin With C.I. Brackets, 15 Mm C.P. Brass Pillar Taps, 32 Mm C.P. Brass Waste Of Standard Pattern, Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls Wherever Require A) White Vitreous China Flat Back Wash Basin Size 550X 400 Mm With Single 15 Mm C.P. Brass Pillar Tap. 17.7.4 4.00 Nos. 1409.35 1352.98 5411.91 4 Providing And Fixing White Vitreous China Flat Back Or Wall Corner Type Lipped Front Urinal Basin Of 430X260X350 Mm And 340X410X265 Mm Sizes Respectively With Automatic Flushing Cistern With Standard Flush Pipe And C.P. Brass Spreaders With Brass Unions And G.I Clamps Complete, Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls And Floors Wherever Required A) One Urinal Basin With 5 Litre White P.V.C. Automatic Flushing Cistern 17.4.1 3.00 Nos. 4918.90 4722.14 14166.42 5 Providing And Fixing Flexible P.V.C. Waste Pipe For Sink Or Wash Basin Including Pvc Waste Fittings Complete. Flexible Pipe 17.28.2 A) 32Mm Dia 17.28.2.1 4.00 Nos. 89.66 86.07 344.29 B) 40Mm Dia 17.28.2.2 2.00 Nos. 89.66 86.07 172.15 6 Providing And Fixing 600X450 Mm Beveled Edge Mirror Of Superior Glass (Of Approved Quality) Complete With 6 Mm Thick Hard Board Ground Fixed To Wooden Cleats With C.P. Brass Screws And Washers Complete. 17.31 4.00 No. 1205.92 1157.69 4630.74 7 Providing And Fixing Cp Brass Single Lever Lelephonic Wall Mixture Of Quality & Make And As Per Thedirection Of Enginer-Incharge. A) 15Mm Dia Nominal Dia. 17.22B 2.00 Each 5205.39 4997.17 9994.34 8 Providing And Fixing 8 Mm Dia C.P./S.S. Jet With Flexible Tube Upto 1 Meter Long With S.S. Triangular Plate For Eureopean Type W.C. Of Quality And Make As Approved By Engineer-In-Charge. 15Mm Nominal Bore 17.16A 2.00 Each 261.85 251.38 502.76 Sanitary Fixtures & Accessories : I 9 Providing And Fixing Ptmt Towel Rail Complete With Brackets Fixed To Wooden Cleats With Cp Brass Screws With Concealed Fittings Arrangement Of Approved Quality And Colour. 600 Mm Long Towel Rail With Total Length Of 645 Mm, Width 78 Mm And Effective Height Of 88 Mm, Weighing Not Less Than 190 Gms. Dsr-17.73.2 1.00 Each 531.69 510.43 510.43 10 Providing And Fixing Ptmt Soap Dish Holder Having Length Of 138Mm, Breadth 102Mm, Height Of 75Mm With Concealed Fitting Arrangements, Weighing Not Less Than 106 Gms. Dsr-18.65 1.00 Each 83.58 80.24 80.24 11 Providing And Fixing C.P. Brass Ablution Health Faucet Assembly With 1.0 M Long Braided Pvc Hose With Mounting Bracket Fixed On Wall Complete.[For Ewc]-Make-Jaquar Ald565 Mr 2.00 Each 1705.00 1636.80 3273.60 12 Providing And Fixing C.P. Brass Two-Way Angle Valve For Ewc Points & For Fixing Ablution Health Faucet Of Approved Quality Conforming To Is:8931. 15 Mm Nominal Bore-Essco Sqt 526A Mr 2.00 Each 1335.00 1281.60 2563.20 1 Providing And Fixing On Wall Face Unplasticised Rigid Pvc Rain Water Pipes Conforming To Is : 13592 Type A Including Jointing With Seal Ring Conforming To Is : 5382 Leaving 10 Mm Gap For Thermal Expansion . (I) Single Socketed Pipes. A) 110Mm Diameter 12.41.2 31.30 Mtr 283.04 271.72 8504.80 2 Making Khurras 45X45 Cm With Average Minimum Thickness Of 5 Cm Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate Of 20 Mm Nominal Size) Over Pvc Sheet 1M X 1 M X 400 Micron, Finished With 12 Mm Cement Plaster 1:3 (1 Cement : 3 Coarse Sand) And A Coat Of Neat Cement,Punning,Rounding The Edges And Making And Finishing The Outlet Complete. A) 110Mm 12.22 7.00 Nos. 223.68 214.73 1503.13 3 Providing And Fixing Unplasticised -Pvc Pipe Clips Of Approved Design To Unplasticised - Pvc Rain Water Pipes By Means Of 50X50X50Mm Hard Wood Plugs, Screwed With M.S. Screws Of Required Length Including Cutting Brick Work And Fixing In Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) And Making Good The Wall Etc. Complete. A) 110Mm 12.43.2 20.00 Nos. 278.47 267.33 5346.54 4 Providing And Fixing On Wall Face Unplasticised Rigid Pvc Rain Water Pipes Conforming To Is : 13592 Type A, Including Jointing With Seal Ring Conforming To Is : 5382, Leaving 10 Mm Gap For Thermal Expansion, (I)Single Socketed Pipes. 110 Mm Diameter 12.41.2 Rm. 283.04 271.72 5 Providing And Fixing To The Inlet Mouth Of Rain Water Pipe Cast Iron Grating 15 Cm Diameter And Weighing Not Less Than 440 Grams. Dsr-12.44 8.00 Nos. 41.02 39.38 315.06 6 Providing And Fixing In Floor And Wall Face Ringfit Upvc Astral Ultradrain Conventional System For Soil And Waste Water Pipes Conforming To (Hsn Code: 3917) Type B Including Jointing With Seal Ring. (I) Double Socketed Pipes. A) 110Mm Dia P.V.C. Pipe Nsr 20.00 Rm. 485.00 465.60 9312.00 B) 90Mm Dia P.V.C. Pipe Nsr 25.00 Rm. 390.00 374.40 9360.00 6 Providing & Fixing Upvc Floor Trap Of Self Cleansing Design With Cp Jali Complete In All Respects. (Make : Supreme / Finolex / Prince) P-Trap Type Floor Trap 110 X 90 Mm Nsr 12.00 No. 195.00 187.20 2246.40 7 Providing And Fixing On Wall Face Unplasticised - Pvc Moulded Fittings/Accessories For Unplasticised Rigid Pvc Pipes Including Jointing With Seal Ring Leaving 10 Mm Gap For Thermal Expansion.. (Make : Supreme / Finolex / Prince) Door Tee 110X110X110 Mm Nsr 2.00 No. 280.00 268.80 537.60 110X110X90 Mm Nsr 2.00 No. 200.00 192.00 384.00 Bend 110 Mm Nsr 2.00 No. 170.00 163.20 326.40 Soil Waste & Vent Pipes And Fittings - Ii 90 Mm Nsr 2.00 No. 160.00 153.60 307.20 1 Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineer In Charge.Lls Etc. (Internal Work) I) Exposed On Wall A) 32Mm Nominal Dia Pipe 18.9.4 30.00 Rm. 328.94 315.78 9473.44 3 Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings Including Fixing The Pipe With Clamps At 1.00M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer In Charge. (Internal Work) I) Exposed On Wall A) 25Mm Dia Nominal Outer Dia Pipes 18.7.3 20.00 Rm. 301.15 289.11 5782.13 4 Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings I/C Fixing The Pipe With Clamps At 1.00M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement And The Cost Of Cutting Chases And Making Good The Same Including Testiang Of Joints Complete As Per Direction Of Engineer In Charge. Concealed Work Including Cutting Chases And Making Good The Walls Etc. A) 15Mm Dia Nominal Outer Dia Pipes 18.8.1 70.00 Rm. 373.34 358.40 25088.28 B) 20Mm Dia Nominal Outer Dia Pipes 18.8.2 20.00 Rm. 403.19 387.06 7741.18 C) 25Mm Dia Nominal Outer Dia Pipes 18.8.3 Rm. 470.42 451.60 5 Providing & Fixing G.I. Pipes Complete With G.I. Fittings & Clamps Including Cutting & Making Good The Walls Etc. (Internal Work) I) Exposed On Wall A) 25Mm Dia Nominal Bore (Medium Duty) Dsr-18.10.3 20.00 Rm. 413.76 397.21 7944.21 Ii) Concealed Pipe Including Painting With Anticorrosive Bitumatic Paint, Cutting Chases And Making Good The Wall. A) 15Mm Dia Nominal Bore Dsr-18.11.1 15.00 Rm. 435.32 417.91 6268.65 2 Painting G.I. Pipes And Fittings With Synthetic Enamel White Paint Over A Ready Mixed Priming Coat, Both Of Approved Quality For New Work. A) 15Mm Dia Nominal Bore. Dsr-18.38.1 15.00 Rm. 14.55 13.97 209.51 B) 25Mm Dia Nominal Bore. Dsr-18.38.3 10.00 Rm. 22.69 21.78 217.79 2 Providing And Fixing 45 Cm Long Unplasticised Pvc Connection Pipe With Brass Unions. A) 15Mm Nominal Bore Dsr18.21.2.1 4.00 Nos. 73.31 70.38 281.51 5 Providing & Fixing Cp Brass Bib Cock Of Approved Quality Conforming To Is 8931 A) 15Mm Nominal Bore 18.49.1 7.00 Nos. 380.09 364.88 2554.19 6 Providing & Fixing C.P. Brass Long Body Bib Cock Of Approved Quality Conforming To Is Standards And Weighing Not Less Than 690 Gms. A) 15Mm Nominal Bore 18.51.1 7.00 Nos. 599.19 575.22 4026.57 7 Providing & Fixing C.P. Brass Angle Valve For Basin Mixer And Gyser Points Of Approved Quality Conforming To Is 8931 A) 15Mm Nominal Bore 18.53.1 14.00 Nos. 430.71 413.48 5788.75 8 Providing And Fixing Gun Metal Gate Valve With Wheel Of Approved Quality. A) 25Mm Dia Nominal Bore 18.17.1 2.00 Each 466.78 448.11 896.23 B) 32Mm Dia Nominal Bore 18.17.2 1.00 Each 517.18 496.50 496.50 C) 50Mm Dia Nominal Bore 18.17.4 Each 769.96 739.16 Water Supply Pipes And Fittings - Iii 9 Providing And Fixing Ball Valve (Brass) Of Approved Quality, High Or Low Pressure, With Plastic Floats Complete 20Mm Dia Nominal Bore 18.18.2 1.00 Each 346.86 332.99 332.99 A) 25 Mm Nominal Bore 18.18.3 2.00 Nos. 348.03 334.10 668.21 10 Providing And Placing On Terrace (At All Floor Levels) Polyethylene Water Storage Tank Of Approved Brand And Manufacture With Cover And Suitable Locking Arrangement And Making Necessary Holes For Inlet, Outlet And Overflow Pipes But Without Fittings And The Base Support For Tank. 18.48 A) Circular Tank 18.48 2500.00 Ltrs 8.25 7.92 19799.33 11 Providing And Fixing Stone Slab Table Rubbed, Edges Rounded And Polished Of Size 75X50Cm Deep And 1.8Cm Thick Fixed In Urinal Partitions By Cutting A Chase Of Appropriate Width With Chase Cutter And Embedding The Stone In The Chase With Epoxy Grout Or With Cement Concrete 1:2:4 (1Cement: 2Coarse Sand: 4Graded Stone Aggregate 6Mm Nominal Size) As Per Direction Of Engineerin-Charge And Finished Smooth. 8.10 Granite Stone Of Approved Shade Dsr-8.10.2 1.08 Sqm. 3038.79 2917.23 3150.61 1 Providing & Fixing Soil, Waste And Vent Pipes. A) 100Mm Dia Centrifugally Cast Iron S & S Pipe. Dsr17.35.1.2 6.00 Rm. 885.53 850.11 5100.67 2 Providing Lead Caulked Joints To Sand Cast Iron/Centrifugally Cast (Spun) Iron Pipes & Fitting Of Diameters. A) 100Mm Dsr-17.58.1 2.00 Each 466.86 448.18 896.37 3 Providing & Fixing M.S. Holder Bat Clamps Of Approved Design To Sand Cast Iron/Centrifugally Cast (Spun) Iron S & S Pipe Embeded In & Including Cement Concrete Blocks 10X10X10Cm. Of 1:2:4 Mix (1 Cement : 2 Coarse : 4 Graded Stone Aggregate 20Mm Nominal Size). Including Cost Of Cutting Holes & Making Good The Walls Etc. A) For 100Mm Dia Pipe. Dsr-17.37.1 2.00 Each 272.13 261.24 522.49 4 Providing & Fixing Cast Iron Trap Of Self Cleansing Design With Or Without Ventarm Complete, Including Cost Of Cutting & Making Good The Walls & Floors. A) 100Mm Inlet & 75Mm Outlet. Dsr17.60.2.1 1.00 No. 1481.31 1422.06 1422.06 5 Providing & Fixing Cast Iron Coller. A) 100Mm Dia. Dsr17.57.1.2 2.00 No. 384.85 369.46 738.91 6 Providing And Fixing Plain Cast Iron S & S Sanitary Bend. A) 100Mm Dsr17.39.1.2 2.00 Nos. 427.52 410.42 820.84 1 Providing And Fixing In Floor And Wall Face Ringfit Upvc Astral Ultradrain Conventional System For Soil And Waste Water Pipes Conforming To (Hsn Code: 3917) Type B Including Jointing With Seal Ring. (I) Double Socketed Pipes. A) 110Mm Dia P.V.C. Pipe Mr 7.50 M 485.00 465.60 3492.00 2 Providing And Fixing Square Mouth S.W. Gully Trap Grade A Complete With C.I. Grating Brick Masonry Chamber With F.P.S. Bricks Of Class Designation 75 And Water Tight C.I. Cover With Frame Of 300 X 300Mm. Size (Inside) The Weight Of Cover To Be Not Less Than 4.50 Kg And Frame To Be Not Less Than 2.70 Kg As Per Standard Design. A) 150 X 100 Mm. Size P Type With Sewer Bricks Conforming To Is : 4885 Dsr-19.4.2.1 1.00 Nos 2050.58 1968.56 1968.56 Soil Waste & Vent Pipes And Fittings - Ii Schedule Of Quantities For Internal Sewerage System - Iv 3 Constructing Brick Masonry Manhole In Cement Mortar 1:4 (1 Cement :4 Coarse Sand) Rcc Top Slab With 1:2:4 Mix (1 Cement :2 Coarse Sand :4 Graded Stone Aggregate 20Mm Nominal Size), Foundation Concrete 1:4:8 Mix (1 Cement :4 Coarse Sand :8 Graded Stone Aggregate 40Mm Nominal Size) Inside Plastering 12Mm Thick With Cement Mortar 1:3 (1 Cement :3 Coarse Sand) Finished With Floating Coat Fo Neat Cement And Making Channels In Cement Concrete 1:2:4 (1 Cement :2 Coarse Sand :4 Graded Stone Aggregate 20Mm Nminal Size) Finished With A Floating Coat Of Neat Cement Complete As Per Standard Design 19.7 Inside Size 90X80Cms And 45Cms Deep Including Ci Cover With Frame (Light Duty) 455X610Mm Internal Diamensions Total Weight Of Cover And Frame To Be Not Less Than 38 Kg (Weight Of Cover 23 Kg And Weight Of Frame 15Kg). 19.7.1 With Fps Bricks Of Class Designation 150 Dsr-19.7.1.1 1.00 Each 9577.59 9194.49 9194.49 External Sewerage Works 1 Excavating Trenches In All Kind Of Soil Of Required Width For Pipes. Including Excavation For Sockets And Dressing Of Sides, Ramming Of Bottoms, Including Getting Out The Excavated Soil & Then Returning The Soil As Required, In Layers Not Exceeding 20 Cm In Depth Including Consolidating Each Deposited Layer By Ramming, Watering, Etc & Disposing Of Surplus Excavated Soil As Directed Within A Lead Of 50M. Up To 1.50 M Depth Pipes 80 Mm To 300 Mm Diameter 2.10.1.2 20.00 Rm 264.10 253.54 5070.79 2 Providing And Fixing In Floor And Wall Face Ringfit Upvc Astral Ultradrain Conventional System For Soil And Waste Water Pipes Conforming To (Hsn Code: 3917) Type B Including Jointing With Seal Ring. (I) Double Socketed Pipes. 160Mm Dia Under Floor (For External Sewer) Nsr 20.00 Metre 1190.00 1142.40 22848.00 3 Constructing Brick Masonry Manhole With F.P.S. Bricks In Cement Mortar 1 : 4 (1 Cement : 4 Coarse Sand) Rcc Top Slab With 1 : 2 : 4 Mix (1 Cement : 2 Coarse Sand : 4 Grade Stone Aggregate 20Mm Nominal Size); Foundation Concrete 1:4:8 Mix (1 Cement : 4 Coarse Sand : 8 Graded Stone Aggregate 40 Mm Nominal Size) Inside Plastering 12 Mm Thick With Cement Mortar 1:3 (1Cement 3 Coarse Sand) Finished With A Floating Coat Of Neat Cement And Making Channels In Cement Concrete 1:2:4 (1Cement : 2 Coarse Sand: 4 Graded Stone Aggregate 20 Mm Nominal Size) Finishd With A Floating Coat Of Neat Cement Complete As Per Standard Design Inside Size 90 X 80 Cm & 45 Cm Deep Including Ci Cover With Frame (Light Duty) 455 X 610 Mm Internal Dimension Total Wt. Of Cover & Frame To Be Not Less Than 38 Kg (Wt. Of Cover 23 Kg And Wt. Of Frame 15 Kg) 19.7.1.1 3.00 Nos 9577.59 9194.49 27583.46 4 Extra For Depth For Manhole With F.P.S. Bricks Size 90 X 80 Cm 19.8.1.1 0.30 Rm 6618.83 6354.07 1906.22 5 Providing M.S. Foot Rests Including Fixing In Manholes With 20*20*10 Cm Cement Concrete Blocks 1:3:6 (1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20 Mm Nominal Size) As Per Standard Design : With 20 X 20 Mm Square Bar 19.15.1 3.00 Nos 408.51 392.17 1176.51 6 Providing And Fixing Square Mouth S.W. Gully Trap Grade `A Complete With C.I. Grating Brick Masonry Chamber With F.P.S Bricks And Water Tight Ci Cover With Frame Of 300 X 300 Mm Size (Inside) The Weight Of Cover To Be Not Less Than 4.50 Kg And Frame To Be Not Less Than 2.70 Kg As Per Standard Design 180 X 150 Mm. Size P Type 19.4.3.1 2.00 Nos 2101.54 2017.48 4034.96 7 Making Soak Pit 2.5 M Diameter 3.0 Metre Deep With 45 X 45 Cm Dry Brick Honey Comb Shaft With Bricks And S.W. Drain Pipe 100 Mm Diameter, 1.8 M Long Complete As Per Standard Design. With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 19.32.1 1.00 Nos 20145.75 19339.92 19339.92 8 Providing M.S. Foot Rests Including Fixing In Manholes With 20X20X10 Cm Cement Concrete Blocks 1:3:6 (1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20 Mm Nominal Size) As Per Standard Design With 20X20 Mm Square Bar Dsr-19.15.1 8.00 Nos. 408.51 392.17 3137.37 9 Providing And Fixing S.C.I. Tee 150 Mm At The Inlet And Outlet Of Septic Tank. Dsr-7087 2.00 Nos. 621.00 596.16 1192.32 10 Providing And Fixing Soil, Waste And Vent Pipes:75 Mm Diameter Sand Cast Iron S&S Pipe As Per Is: 1729 Dsr17.35.2.1 3.00 Rmt. 783.54 752.19 2256.58 11 Providing & Fixing Of 75Mm Dia Sand Cast Iron S&S As Per Is - 1729 Terminal Guard. Dsr17.56.2.1 2.00 Nos. 255.52 245.30 490.59 12 Providing & Fixing 75Mm Plane Sand Cast Iron S&S Bend Of Required Drgtee. Dsr17.39.2.1 2.00 Nos. 282.18 270.89 541.78 13 Providing Lead Caulked Joints To Sand Cast Iron/ Cetrifugally Cast (Squn) Irons Pipes & Fitting Of 50 Mm Dia Dsr-17.58.2 2.00 Nos. 394.67 378.89 757.77 14 Providing And Fixing In Position Precast Rcc Manhole Cover And Frame Of Required Shape And Approved Quality.M.D. -10- Circular Shape 500Mm Internal Diameter Dsr19.19.2.2 2.00 Nos. 879.42 844.24 1688.49 1 Wiring For Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq.Mm Frls/Hffr Pvc Insulated Copper Conductor Single Core Cable In Surface/ Recessed Medium Class Pvc Conduit, With Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm Frls/Hffr Pvc Insulated Copper Conductor Single Core Cable Etc. As Required Dsr 1.10.3 51.00 Each 1115.37 1070.76 54608.68 2 Wiring For Twin Control Light Point With 1.5 Sq.Mm Frls/Hffr Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Medium Class Pvc Conduit, 2Way Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm Frls/Hffr Pvc Insulated Copper Conductor Single Core Cable Etc. As Required Dsr 1.11 4.00 Each 1187.60 1140.10 4560.39 3 Supplying And Fixing Of Following Sizes Of Medium Class Pvc Conduit Along With Accessories In Surface/Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. Dsr 1.21.1 17.00 Metre 97.32 93.43 1588.26 4 Wiring For Circuit/ Submain Wiring Along With Earth Wire With The Following Sizes Of Frls/Hffr Pvc Insulated Copper Conductor, Single Core Cable In Surface/ Recessed Medium Class Pvc Conduit As Required.2 X 1.5 Sq. Mm + 1 X 1.5 Sq. Mm Earth Wire Dsr 1.14.1 650.00 Metre 177.15 170.07 110542.86 5 Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface/ Recessed Medium Class Pvc Conduit As Required 2 X 2.5 Sq. Mm + 1 X 2.5 Sq. Mm Earth Wire Dsr 1.14.2 188.00 Metre 285.12 273.71 51457.72 6 Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface/ Recessed Medium Class Pvc Conduit As Required 2 X 4 Sq. Mm + 1 X 4 Sq. Mm Earth Wire Dsr 1.14.3 202.00 Metre 253.94 243.79 49244.67 7 Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface/ Recessed Medium Class Pvc Conduit As Required 2 X 6 Sq. Mm + 1 X 6 Sq. Mm Earth Wire Dsr 1.14.4 105.00 Metre 333.78 320.42 33644.59 8 Supplying And Fixing Suitable Size Gi Box With Modular Plate And Cover In Front On Surface Or In Recess, Including Providing And Fixing 6 Pin 5/6 & 15/16 A Modular Socket Outlet And 15/16 A Modular Switch, Connections Etc. As Required Dsr 1.32 22.00 Each 445.54 427.72 9409.83 9 Supplying And Fixing Brass Batten/ Angle Holder Including Connection Etc. As Required Dsr 1.34 15.00 Each 99.60 95.62 1434.25 Electrical Works 10 Installation ,Testing, Commissioning Of Wall Bracket /Ceiling Fittings Of All Sizes And Shapes Containing Upto Two Ls/Cfl/Led Lamps Per Fitting, Complete With All Accessories Including Connections Etc. As Required. Dsr 1.35 1.00 Each 90.48 86.86 86.86 11 Supplying, Installation, Testing & Commissioning Of Led Recessed/ Surface Down Lighter (Round/ Square/ Rectangular) Smd Type Of Following Body Material With Pmma And Prismatic Diffuser And Construction As Per Is : 10322 With Driver As Per The Requirement With Driver Efficiency >85%, Operating Voltage Ac 140-270 Volt, Frequency 50/60 Hz, Operating Temp Range -50C To 400C, Internal Surge Protection Of 2.5 Kv With Short & Open Circuit Protection ,Thd < 10% , P. F.≥0.95, Ip20, Cri >80, Ugr (Unified Glare Rating) < 19, Flicker Free (Flicker Should Be Below 5%), Life Time (Led, Driver & Electrical Circuitry), Of Minimum 50000 Burning Hours With 70% Of Initial Lumen Maintained Till Life Ends, Cct 3000°K /4000°K / 5700°K / 6500°K (As Per Ansi Bin), Sdcm (Standard Deviation Colour Matching) <3, Maximum Power Consumption Should Not More Than The Specified Rating And Fixture Shall Be Confirming To Relevant Bis Standards. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen Printing On Housing Complete In All Respect I/C External Connections With 1.5 Sq.Mm Frls/Hffr, Pvc Insulated Copper Conductor Single Core Cable And Earthing Etc. As Required With Minimum 5 Year Oem Warranty. System Lumen Efficacy ≥105 And <120 Lm/Watt Output . Lm79 & Lm80 Test Report And All Testing Required For Led Fixtures As Per Bis Shall Be Submitted. Shape Size And Cct Shall Be As Approved By Engineer-In-Charge As Per Requirement. (Thermal Management: Heat Sink Of Aluminium Housing Such That Led Junction Temperature Shall Not Rise Above 90°C) Powder Coated Die Cast /Extruded Aluminium Body Including Trim 18 Watt Mr 19.00 Each 700.00 672.00 12768.00 12 Earthing With G.I. Earth Plate 600 Mm X 600 Mm X 6 Mm Thick Including Accessories, And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Of 2.7 Metre Long Etc. With Charcoal/ Coke And Salt As Required Dsr-5.4 3.00 Each 5681.03 5453.79 16361.37 13 Supplying And Laying 25 Mm X 5 Mm G.I Strip At 0.50 Metre Below Ground As Strip Earth Electrode, Including Connection/ Terminating With G.I. Nut, Bolt, Spring, Washer Etc. As Required. (Jointing Shall Be Done By Overlapping And With 2 Sets Of G.I. Nut Bolt & Spring Washer Spaced At 50Mm) Dsr 5.9 55.00 Metre 109.48 105.11 5780.78 14 Supplying And Fixing 5 A To 32 A Rating, 240/415 V, 10 Ka, C Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. A) Single Pole Dsr-2.10.1 9.00 Each 194.64 186.85 1681.68 15 Supplying And Fixing Following Way, Single Pole And Neutral, Sheet Steel, Mcb Distribution Board, 240 V, On Surface/ Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Including Earthing Etc. As Required. (But Without Mcb/Rccb/Isolator) A) 6 Way (4 + 12), Double Door Dsr-2.3.1 2.00 Each 1677.24 1610.15 3220.30 16 Supplying And Fixing Following Way, Horizontal Type Three Pole And Neutral, Sheet Steel, Mcb Distribution Board, 415 V, On Surface/ Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Including Earthing Etc. As Required. (But Without Mcb/Rccb/Isolator) A) 4 Way (4 + 12), Double Door Dsr-2.4.1 1.00 Each 3110.42 2986.01 2986.01 17 Supplying And Fixing 5 A To 32 A Rating, 240/415 V, 10 Ka, C Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. Dsr-2.10.3 2.00 Each 498.76 478.81 957.62 16 Installation, Testing And Commissioning Of Ceiling Fan, Including Wiring The Down Rods Of Standard Length (Upto 30 Cm) With 1.5 Sq. Mm Frls Pvc Insulated, Copper Conductor, Single Core Cable, Including Providing And Fixing Phenolic Laminated Sheet Cover On The Fan Box Etc. As Required Dsr 1.45 10.00 Each 257.74 247.43 2474.35 17 Supplying And Fixing Two Module Stepped Type Electronic Fan Regulator On The Existing Modular Plate Switch Box Including Connections But Excluding Modular Plate Etc. As Required. Dsr 1.25 10.00 Each 280.55 269.33 2693.32 18 Installation Of Exhaust Fan In The Existing Opening, Including Making Good The Damage, Connection, Testing, Commissioning Etc. As Required. Upto 450 Mm Sweep Dsr-1.50.1 7.00 Each 342.14 328.45 2299.17 19 Extra For Fixing The Louvers/ Shutters Complete With Frame For A Exhaust Fan Of All Sizes Dsr-1.51 7.00 Each 157.38 151.09 1057.62 20 Supply, Installation, Testing And Commissioning Of Ceiling Fan With Brush Less Direct Current (Bldc) Motor, Class Of Insulation: B, 3 Nos. Metal( Aluminium Alloy) Blades, 30 Cm Long Down Rod, 2 Nos. Canopies, Shackle Kit, Safety Rope, Copper Winding, Steel/Al Body Power Factor Not Less Than 0.9, Service Value (Cm/M/W) Minimum As Below, 350 Rpm (Tolerance As Per Is : 374-2019), Thd (Total Harmonic Distortion) Less Than 10%, Suitable For Operation With Regulator For Speed Control And All Remaining Accessories Including Safety Pin, Nut Bolts, Washers, Temperature Rise=75 0C (Max.), Insulation Resistance More Than 2 Mega Ohm, Suitable For 230 V, 50 Hz, Single Phase Ac Supply, Ceiling Fan Compliant To Is 374:2019 Fan I/C External Connections With 1.5 Sq.Mm Frls/Hffr, Pvc Insulated Copper Conductor Single Core Cable And Earthing Etc. As Required. 9.2.3 10.00 Each 2075.64 1992.62 19926.18 21 Supplying And Laying Of Aluminium Conductor Pvc Insulated Armoured Served Sheathed Cable 1100 Volts Grade At The Depth Of 750 Mm Bellow Ground Level Over A Cushion Of 75 Mm Thick Sand All Around And Protected With Burnt Bricks On Side And On Top .On Surface The Cable Run Shall Be Fixed On Ms Clamps Etc.Of Suitable Size Or As Directed By The Engineer-Incharge ,Complete In All Respect.The Armouring Of The Cable Shall Be Properly Connected With The Earth Conductor By Clamps Etc. Following Size 10 Sqmm X 2 Core Mr 164.00 Rm 410.34 393.93 64603.77 22 Supply & Fixing Of 225/230Mm Sweep Ventilating (Light Duty) Exhaust Fan Complete With Metallic Blade (Steel Bird Guard Protector /Copper Motor For High Air Suction Performance /Capacitor Etc.), Noise Level : (45 - 50) Db, Power Consumption : 45 W, Rated Voltage : 230 V, Rated Frequency : 50 Hz, Motor Type : Normal Speed. Complete In All Respect. Mr 7.00 Each 1665.00 1598.40 11188.80 23 Cost For Murals Work 32.40 Sqm 5850.00 5616.00 181958.40 24 Cost For Solar Street Light With 7M Pole Complete 15.00 Nos 22600.00 21696.00 325440.00 25 Cost For C.C. Bench 12.00 Nos 10000.00 9600.00 115200.00 26 Cost For Dustbin 6.00 Nos 4500.00 4320.00 25920.00 1. Trenching In Ordinary Soil Up To A Depth Of 60 Cm Including Removal And Stacking Of Serviceable Materials And Then Disposing Of Surplus Soil, By Spreading And Neatly Levelling Within A Lead Of 50 M And Making Up The Trenched Area To Proper Levels By Filling With Earth Or Earth Mixed With Sludge Or / And Manure Before And After Flooding Trench With Water (Excluding Cost Of Imported Earth, Sludge Or Manure).. (Horti) 2.1 159.24 Cum 74.51 71.53 11389.98 2 Supplying And Stacking Of Good Earth At Site Including Royalty And Carriage Upto 5 Km Lead Complete (Earth Measured In Stacks Will Be Reduced By 20% For Payment). (Horti) 2.2 79.62 Cum 491.88 472.21 37597.13 Horticulture 3 Supplying And Stacking At Site Dump Manure From Approved Source, Including Carriage Upto 5 Km Lead Complete (Manure Measured In Stacks Will Be Reduced By 8% For Payment) : Screened Through Sieve Of I.S. Designation 20 Mm (Horti) 2.4.1 106.16 Cum 242.46 232.76 24709.88 4 Spreading Of Sludge, Dump Manure And / Or Good Earth In Required Thickness As Per Direction Of Officer-In-Charge (Cost Of Sludge, Dump Manure And / Or Good Earth To Be Paid Separately). (Horti) 2.8 159.24 Cum 49.94 47.94 7634.64 5 Mixing Earth And Sludge Or Manure In The Required Proportion Specified Or Directed By The Officer-In-Charge (Horti) 2.9 159.24 Cum 34.87 33.47 5330.39 6 Grassing With Selection No.1 Grass Including Watering And Maintenance Of The Lawn For 30 Days Or More Till The Grass Forms A Thick Lawn, Free From Weeds And Fit For Mowing Including Supplying Good Earth, If Needed (The Good Earth Shall Be Paid For Separately). In Rows 5 Cm Apart In Both Directions. (Horti) 2.10.1 530.80 Sqm 16.89 16.21 8604.46 7 Providing And Displaying Of Aglaonema Silver Queen Having 30 Cm To 45 Cm. Ht. With 12 To 15 Leaves, Multi Suckers, Fresh And Healthy Leaves, Well Developed In 25 Cm Dia Earthen Pot/Plastic Pot & As Per Direction Of The Officer-In-Charge. (Horti) 3.8 60.00 Each 154.50 148.32 8899.22 (Horti) Dsr 3.8 8 Providing And Displaying Of Aglaonema Dove Variety Having Ht. 30 Cm To 45 Cm With 8 To 10 Leaves, Well Developed, Fresh And Healthy In 25 Cm Size Of Earthen Pot/Plastic Pot & As Per Direction Of The Officer-In-Charge. (Horti) 3.4 75.00 Each 77.42 74.32 5574.03 (Horti) Dsr 3.4 9 Providing And Displaying Of Aglaonema Marentifolium Variety Having Ht. 23 Cm To 30 Cm With 8 To 10 Leaves, Well Developed, Fresh And Healthy With Colorful Leaves In 20 Cm Size Of Earthen Pot/Plastic Pot. & As Per Direction Of The Officer-In-Charge. (Horti) 3.10 50.00 Each 64.54 61.96 3097.83 (Horti) Dsr 3.10 10 Providing And Displaying Of Chamaedorea Elegans Palm Having Ht. 60 Cm To 75 Cm, Well Developed With Fresh And Healthy Leaves In 25 Cm Size Of Earthen Pot/Plastic Pot. & As Per Direction Of The Officer-In-Charge. (Horti) 3.26 50.00 Each 102.70 98.59 4929.51 (Horti) Dsr 3.26 11 Providing And Displaying Of Croton Baby Golden Variety Having Ht.30 Cm And Above, Well Developed With Full Of Fresh And Healthy Leaves In 20 Cm Size Of Earthen Pot/Plastic Pot & As Per Direction Of The Officer-In-Charge. (Horti) 3.28 150.00 Each 39.11 37.55 5632.42 (Horti) Dsr 3.28 12 Providing And Displaying Of Croton Golden (Broad Leaves) Having Ht. 60 Cm To 75 Cm With 3 To 4 Branches, Well Developed, Fresh And Healthy Leaves In 25 Cm Size Of Earthen Pot/Plastic Pot. & As Per Direction Of The Officer-In-Charge. (Horti) 3.32 150.00 Each 53.81 51.65 7748.01 (Horti) Dsr 3.32 13 Providing And Displaying Of Dieffenbachia Tropic-Snow Having Ht. 60 Cm & Above With 8 - 10 Leaves, Well Developed, Fresh & Healthy In 25 Cm Size Of Earthen Pot/Plastic Pot & As Per Direction Of The Officer-In-Charge. (Horti) 3.40 50.00 Each 75.32 72.31 3615.28 (Horti) Dsr 3.40 14 Providing And Displaying Of Dieffenbachia Mosaic Having Ht. 30Cm To 45 Cm With 10-12 Leaves, Well Developed, Fresh And Healthy In 25 Cm Size Of Earthen Pot/Plastic Pot. & As Per Direction Of The Officer-In-Charge. (Horti) 3.41 50.00 Each 75.32 72.31 3615.28 (Horti) Dsr 3.41 15 Providing And Displaying Dianthus In Different Colour Well Developed With Fresh & Healthy Foliage 30 Cm Ht., In Full Bloom With Stacking In 25 Cm Earthen Pot/Plastic Pot And As Per Direction Of The Officer-In-Charge. (Horti) 4.29 50.00 Each 51.79 49.72 2486.05 (Horti) Dsr 4.29 16 Providing And Displaying Gazania Hybrid In Different Colour Well Developed With Fresh & Healthy Foliage With Full Bloom In 25 Cm Earthen Pot/Plastic Pot And As Per Direction Of The Officer-Incharge. (Horti) 4.31 150.00 Each 61.63 59.16 8874.49 (Horti) Dsr 4.31 17 Providing And Displaying Gaillardia Double Hybrid Variety Well Developed 30 To 45 Cm Ht 20 To 30 Fresh & Healthy Flower With Green Painted Bamboo Stick In 25 Cm Earthen Pot/Plastic Pot And As Per Direction Of The Officer-In-Charge. (Horti) 4.75 120.00 Each 51.85 49.78 5973.11 (Horti) Dsr 4.75 18 Providing And Stacking Of Plant Mogra Of Height 25 To 30 Cm., 2 To 3 Branch In Earthen Pots Of Size 20 Cm Earthen Pot/Plastic Pot And As Per Direction Of The Officer-In-Charge. (Horti) 4.88 100.00 Each 44.03 42.27 4226.60 (Horti) Dsr 4.88 19 Providing And Stacking Of Plant Canna Dwarf Of Height 25 To 30 Cm., 2 To 3 Suckers In Earthen Pots Of Size 20 Cm Earthen Pot/Plastic Pot And As Per Direction Of The Officer-In-Charge. (Horti) 4.89 100.00 Each 34.25 32.88 3287.87 (Horti) Dsr 4.89 20 Bush Rose In Different Colour 2 To 3 Healthy Branch 30 Cm And Above Ht. Well Developed With 8 Or More Flowers / Flower Buds In 20 Cm Earthen Pot /Plastic Pot As Per Direction Of The Officer-Incharge. (Horti) 4.90 100.00 Each 24.47 23.49 2349.13 (Horti) Dsr 4.90 21 Providing And Displaying Budded Rose (H.T. Variety) 3 To 4 Healthy Branch 30 Cm And Above Ht. Well Developed With One And Above Flower Plant In 20 Cm Earthen Pot, As Per Direction Of The Officer-In-Charge. (Horti) 4.91 100.00 Each 31.29 30.04 3003.96 (Horti) Dsr 4.91 22 Providing And Displaying Standard Rose (H.T. Variety) 3 To 4 Healthy Branch 90 Cm And Above Ht. Well Developed With One And Above Flowers In 25 Cm Earthen Pot, As Per Direction Of The Officer-In-Charge. (Horti) 4.93 75.00 Each 143.77 138.02 10351.28 (Horti) Dsr 4.93 23 Providing And Stacking Of Plumeria Rubra Of Height 120-150 Cm. With 3-4 Branches And Thick Stem In Big Size Hdpe Bags As Per Direction Of The Officer-In-Charge. (Horti) 7.72 75.00 Each 381.60 366.34 27475.20 (Horti) Dsr 7.72 24 Providing And Stacking Of Polyalthia Longifolia (Ashok) Of Height 180-195 Cm. In Gunny Bag Of Size 30 Cm As Per Direction Of The Officer-Incharge. (Horti) 7.75 75.00 Each 95.40 91.58 6868.80 (Horti) Dsr 7.75 25 Providing And Stacking Of Saraca Indica (Sita Ashok) Of Height 105-120 Cm. In Big Poly Bags Of Size 25 Cm As Per Direction Of The Officer-In-Charge. (Horti) 7.80 75.00 Each 76.32 73.27 5495.04 (Horti) Dsr 7.80 26 Providing And Stacking Of Terminalia Arjuna Of Height 150-165 Cm. In Big Polybags Of Size 25 Cm As Per Direction Of The Officerin-Charge. (Horti) 7.88 75.00 Each 57.24 54.95 4121.28 (Horti) Dsr 7.88 27 Providing And Stacking Of Calliandra, Emarginata Of Height 45-60 Cm. In Earthen Pot Of Size 20 Cm As Per Direction Of The Officer-Incharge. (Horti) 8.5 150.00 Each 33.39 32.05 4808.16 (Horti) Dsr 8.5 28 Providing And Stacking Of Nerium Oleander (Kaner) Of Height 60- 75 Cm. With 5-6 Branches In Poly Bags Of Size 25 Cm As Per Direction Of The Officer-In-Charge.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
Uttar Pradesh View Result →
20.
Educational and Research Institute #11307547 Technical Bid
Tender For supply of Cardiology Implants And Consumables-1 Balkin sheath 6 f/ 7F with side extension port cross over sheath 2 Long sheath 6f 45cm length 3 Long sheath 6f 60 cm length 4 Long sheath 7f 45cm length 5 Inflation device for coronary balloon inflation 20ml-30ml capacity with 25ATM - 30ATM 6 PTA Guide wire .014 300cm length J tip /straight tip 7 Guide wire .032 150cm length Terumo type J tip /straight tip 8 PTA Guide wire .032 260cm length Terumo type J tip /straight tip 9 Guide wire .035 150cm length Terumo type J tip /straight tip 10 PTA Guide wire .035 260cm length Terumo type J tip /straight tip 11 Magic Torque Hydrophilic Coated Straight Tip Guide wire, 180 cm Length shapable tip. 12 Carotid access sheath 7f with kit shuttle guiding sheath ,90cm/110cm length 13 PTA Balloon .035Wire compatible all diameter and all lengths. 14 PTA Balloon OTW .018 Wire compatible ,all diameter and all lengths 15 PTA Balloon .018 Wire compatible ,all diameter and all lengths 16 PTA Drug coated Balloon (paclitaxel/sirolimus)OTW .035 Wire compatible ,all diameter and all lengths 17 PTA Drug coated Balloon (Paclitaxel/sirolimus) .018 Wire compatible OTW ,all diameter and all lengths 18 PTA Drug coated Balloon (Paclitaxel/sirolimus) .018 Wire compatible ,all diameter and all lengths 19 Peripheral stent self expandable .035 Wire compatible all diameter and all lengths 20 Peripheral stent self expandable .018 Wire compatible all diameter and all lengths 21 Peripheral stent balloon expandable .018 Wire compatible all diameter and all lengths 22 Renal stents .014 Wire compatible, all diameter and all lengths 23 Carotid stents .014 Wire compatible self expandable all diameter and all lengths 24 covered stent for peripheral Angioplasty .035 Wire compatible, all diameter and all lengths. 25 covered stent for peripheral Angioplasty OTW .035 Wire compatible, all diameter and all lengths. 26 Peripheral stent self expandable OTW.035 Wire compatible all diameter and all lengths 27 Peripheral stent self expandable OTW .018 Wire compatible all diameter and all lengths 28 Brokenbrough septal puncture needle,Trans septal puncture needle (Complete set) 29 PTMC ,BMV ,balloon all sizes 19mm-28mm diameters 30 BMV Set ( Mullins sheath, Mullins dilator, LA wire, deflecting wire ,Ruller, stylet, syringe) 31 IVC FILTER 6F compatible with kit 32 IVC FILTER 6F compatible with kit Retrievable 33 Flash ballon for proximal optimization for coronary. 014 Wire compatible. 34 Foreign body reterival snares ,for coronary, goose neck type all sizes 35 Foreign body reterival snares ,for peripheral , goose neck type all sizes 36 Aortic stent self expandable all diameter and all lengths. 035 Wire compatible 37 venous peripheral stent .35 compatible all diameter and all lengths 38 vascular access sheath 8f -14f .038Wire all lengths 39 Vascular plug , recapturable and respositionable all sizes 40 Glue (n-butyl-2-cyanoacrylate) 41 coil for paediatric use all sizes and all lengths 42 coil pusher for .018,.032 all sizes and all lengths 43 EMBOLIC PROTECTION DEVICE - It is nitinol briaded filter with gold tungsten maker around the mouth fo filter and radiopaque distal and proximal markers, capture wire 320cm , only protection device that can be used in lower extrimities. Filters proximal end around mouth is 250 microns, mid is 165 microns and distal is 70 microns. Dual end cahteter, one peice delivery and capture dual rapid exchange catheter, indicated in SVG stenting, carotid stenting and for lower extremities.nitinol , monorail 0.014 guidewire and 6f sheath compatable with filter size 3mm - 7mm and delivery end crossing profile 3.2mm, recovery end crossing profile 4.2mm with capture wire 320cm Distal protection Device .014 compatible ,Embolic protection device conical filter shape .014 wire compatible 44 Covered Graft stent for aorta all sizes . 45 (BIB)Balloon in Balloon all sizes for aorta . 46 PTA Balloon with unique score flex balloon material which reduces balloon wall thickness having broadest range of sizes with longest lengths upto 220mm 47 Dual layer High pressure PTA Balloon with unique balloon material (nylon + pebax ) also with advanced balloon folding technology for excellent rewrap and dual lumen shaft design 48 Diagnostic Angiography Catheter 3F-5F, for Paediatrics use, all curves and All shapes 49 Diagnostic Angiography catheters special curves like MPA, NIH, PIG, etc, 100/125cm lengths , 5f/6f 50 Marker Pigtail 5 Fr-6fr,100/125cm length, Marker Pigtail Marker Pigtail All codes Performa Vessel Sizing 51 Microcatheter (0.18coil compatible) all lengths 52 Mullins sheath all size 038,6fr-10 fr ,all length. 53 POT balloon for coronary .014 wire compatible all sizes 54 CTO balloon for coronary .075mm -1.5mm, 0.014 wire compatible 55 Angioplasty wire .014, 190cm hydrophilic coated tip load 3.5g. radiopaque 15cm stainless steel composite core 56 Angioplasty wire .014, 190cm hydrophilic coated tip load 4.5g. radiopaque 15cm stainless steel composite core 57 Angioplasty wire .014, 190cm tapered coe 2g tip load with extrand coil tapered micro stainless steel composite core 58 Angioplasty wire .014, 190cm stainless steel core hydrophilic coated tip load 5.5g. radiopaque 11cm 59 Microcatheter .014 wire compatible 145cm/135cm length braded with stainless steel distal floppy 13 cm segment with hydrophilic tip 1.8f-2.1f , tip crossing profile 1.8f-2.1 60 Vascular closure Device 6f-8f restorable collagen anchor ad suture. 61 Micropuncture set 21G needle , 4f - 7f 0.018wire . 62 Sirolimus Drug Eluting stent system with Cobalt chromium platform,60 micron strut thickness. Biodegradable PLGA polymer, Abluminal coating , 3mm hydrophilic coating from tip to Balloon shoulder to enhance trackability in complex cases, with All Diameters and All lengths in (mm) (USFDA/CE/DCGI Approved) 63 Sirolimus Drug Eluting stent system with Cobalt chromium platform, 65 micron strut thickness. (USFDA/CE/DCGI Approved), Biodegradable PLGA polymer,unique open and closed cell design with strut locking mechanism,this offers excellent radial strength and minimum recoil. with All Diameters and All lengths in (mm) (USFDA/CE/DCGI Approved). 64 Everolimus ,Drug Eluting stent system with Cobalt chromium platform. with All Diameters and All lengths in (mm)(USFDA/CE/DCGI Approved) 65 Specialised proximal optimisation balloon dilatation catheter with ultra short balloon shoulder of 0.6mm and an RBP of 22 atm with sizes ranging from a length of 6-15 mm and diameters ranging from 2.25-5 mm. Hydrophilic external surface coating from tip to adjacent guidewire port and silicone coating inside guidewire lumen. 66 PTCA Wire .014, with Nitinol Alloy Distal Core and M Coat Hydrophillic Coating, varying tip load 67 PTCA High Pressure CTO Balloon 0.75 mm CTO balloon with a tip entry profile of 0.015” and ultra low crossing profile of 0.020” with a proprietary distal welding technology, 2.2F distal shaft, Rated Burst Pressure of 20 ATM and Average Burst Pressure of ≥ 28 ATM. Diameters from 0.75mm, 1.0mm, 1.25mm, 1.50mm, 1.75mm & 2.0mm and lengths from 5mm, 8mm, 10mm, 15mm, 20mm, 25mm & 30mm. 68 Introducer Needle for Femoral Puncture Introducer needle 18 Gauge 7.0 cm length with straight entry port CE approved 69 Introducer Needle suitable for Radial Puncture Introducer needle 20 Gauge 3.8 cm length with straight entry port CE approved 70 AICD Dual Chamber mri Safe, Standard Features ,DICD Dual Chamber MRI, Rate Responsive,wireless ICD, 40J shock Device, Auto sensitivity, Onset, Stability, sustained VT,Smart Detection, 5 years warranty 71 Endocardial Lead (Defibrillator) for ICD PassiveTinned /Active fixation Leads DF1 & DF4 both.Dual Coil Lead. All lengths of Leads should be available as per Clinical Need.MRI Conditional 72 Endocardial lead RA Passive Tined /Active fixation MRI safe. 73 Introducer sheath for lead 7-9F PEELABLE INTRODUCER 74 Renal stent balloon expandable Semi-complaint balloon mounted CobaltChromium stent,Rapid exchange shaft length 90 & 150 cm, All diameters & All lengths,0.014 & 0.018 wire compatible. 75 Guiding Catheters for Angioplasty, all shapes, 5F-8F, for Femoral route 100cm length 76 Guide Extension Catheter available in variable diameters of 4.7F and 5.0F for accessing distal anatomy and delivering high profile devices; Guide Extension Catheter with a tapered distal shaft for accessing distal and challenging coronary anatomy; Guide Extension Catheter with a Resinous atraumatic tip; Guide Extension Catheter with a large entry port design for easy device insertion motheter and child catheter , guide liner all sizes 77 Coronary Angioplasty balloons, Semi compliant, OTW System Semi-complaint coronary Balloon with Slim Seal Technology on distal tip and tip entry profile<=0.017” available in diameter 1.2mm -5.00mm and lengths 6-30mm 78 Drug coated Balloon dilation catheter with wing seal tech (Paclitaxel/sirolimus) .014 ,all diameter and all lengths for coronary. 79 Everolimus/Sirolimus,Drug Eluting stent system with Cobalt chromium platform with, small strut thickness, with low shaft profile All Diameters and All lengths 80 Dual lumen Microcatheter with oval design and stainless steel core. 81 Coils for micro vessels , all sizes and all lengths 82 5/6/7/8/10/12 Fr. Sheath with Dilators - for TAVI 83 Proglide - 18- for TAVI 84 0.035 Safari Wire - Small & Extra small - exchange length for TAVI 85 0.035 lunderquist Double curve wire - exchange length for TAVI 86 0.035Amplatz Extra Stiff J Tip wire - exchange length for TAVI 87 Regular length , 0.035, straight tipped, Teflon coated guide wire for TAVI 88 Balloon tipped temporary pacemaker lead 6F/&7F for TAVI 89 Peripheral guide wire V14/V18 300cm wire for TAVI 90 Peripheral Vascular Balloon (PTA) 6x40mm/6x60mm/7x40mm/7x60mm for TAVI 91 Fluency stent 6x40mm/6x60mm/7x40mm/7x60mm/8x40mm/8x60mm for TAVI 92 Micro puncture set 4f/5f with 7cm needle for TAVI 93 Angioseal 8f for TAVI 94 HIS bundle KIT , select secure Mri C315 catheter & slitter 95 covered stent for coronary Angioplasty .014 Wire compatible, all diameter and all lengths. 96 Vascular access sheath 6f-9f all lengths with puncture needle (18g , 7cm) 97 TAVI Valve ( all sizes) 98 Balloon flotation catheter ( Swan - Ganz) 99 VSD closure Device Multifunction Occluder), All sizes 100 VSD closure delivery cable ( AGA type/ NON- AGA type) , All sizes 101 VSD closure delivery sheath with haemostatic valve for VSD ( AGA type/ NON- AGA type) , All sizes 102 VSD closure Device ( Muscular & Perimembranous ( AGA type/NON- AGA type) , All sizes 103 6F compatible Orbital Atherectomy device with 1.25mm diamond coated crown designed for bidirectional superficial calcium sanding and modify deep calcium through pulsatile forces to facilitates stent delivery and expansion in severely calcified lesions with durable nitinol guidewire with 0.12” proximal and 0.14” distal end along with viper slide lubricant. 104 Vascular Suture-Mediated Closure & Repair System (Sterile), with 3.0 Monofilamint Polypropylene Suture, 300 Series Stainless Steel Needles, Depth Reference Markers on Proximal Guide & Suture Trimmer. 105 USFDA approved non-complaint coronary balloon with single piece outer member and multilayer CrossFlex Balloon Technology made up of pebax (1.5mm to 5.00mm) & grilamid (5.5mm-6.00mm). Faster deflation time of ~ 7secs. Round Tip with Lesion Entry Profile of 0.020” available in diameter 1.5mm-6mm and lengths in 6mm-25mm with Skive Technology on Mid shaft of Dilatation Catheter. 106 CTO Guidewire having Durasteel Core, Micro textured tip and Pre-Shaped Micro-J Tip with a length of 1 mm at an angle of 25°. Tipload between 14gm and penetration power of 224kg/in2. 3 cm Radiopaque Tapered Platinum Nickel (PtNi) Tip Coil 107 wireless FFR Guidewire, 175cm, 0.014 Guidwire,high-fidelity piezo electric pressure sensor technology, mulitiple large windows(multi window), radio-opaque tip, radio range of atleast 2m, battery time atleast 3 hours, wireless frequency range 2.4000-2.4835GHz 108 Guide catheter for intracoronary OCT, 0.014 guidewire and 6 F guide catheter compatibility. Lubricous hydrophilic coating and low tip entry profile for crossing tight, distal lesions.2.7 F crossing profile and supportive proximal shaft provide superb deliverability to the area of interest. Lens marker is immediately proximal to imaging lens and the distance of lens marker from tip should be 23 mm and proximal marker at 82 mm from the lens marker. Three radiopaque marker  109 Everolimus Eluting Cobalt chromium DES, thin strut thickness 0.0032’’ , Durable Biocompatible Fluorinated copolymer , Multi Link 8, Multilayer pebax balloon mounted, Mid Marker stent placement , with RBP of 18ATM with assorted Sizes till 38mm length, indicated for complex and CTO lesions. With advanced technologies like Skive and CPS with robust hypotube. Along with 12 CE indications with the shortest DAPT indication of 28 days in HBR patients. 110 Temporary Bipolar Pacing Catheter- Torque Control - US FDA & DCGI approved, 10 cm depth markers to enhance placement, smooth, polyurethane hemocompatible coating, clearly marked terminals, shrouded 2 mm pin connector leads, stainless steel centre conductor and stainless steel electrodes, solid core enables user to customize the curve, optimal torque control for challenging anatomy 111 Temporary Bipolar Pacing Catheter- Flow Directed - Should be Latex Balloon Tipped, Flow Guided for stable insertion, 10 cm depth markers to enhance placement, US FDA & DCGI approved, smooth, polyurethane hemocompatible coating, clearly marked terminals, shrouded 2 mm pin connector leads, Should have platinum electrodes, flexible tip design for delicate placement. 112 ACIST KODAMA Catheters 40/60 MHz • Single catheter having dual frequency (40MHz &60MHz) with applications across both coronary and peripheral vascular systems. • The sheath assembly is coated with a hydrophiliccoating. • 6 Fr to 8 Fr guide catheter capability or guide sheath with a minimum internal diameter of 0.064in (1.63 mm). • Short(≤ 2.0 cm) monorail guidewire engagement system compatible with commercially available 0.014 in guidewires • Novel offset tip design with distal tip entry profile ≤ 2.0 Fr, the crossing profile ≤ 3.2 Fr, and theworking length ≥ 141 cm. • The catheter has a ≥ 12 cm long VariFlexTM imaging window having improved deliverability andassociated telescope assembly 113 |1VL Catheter and Connector Cable,- Intravascular Lithotripsy Intuitive Catheter with Rx system for treating highly calcified lesions,- Integrated 12mm SC balloon,- NP - 6atm/ RBP - 10 atm, |Diameters:2.5,3.0,3.5,4.0mm,-2 emitters (80 pulses per catheter) -US FDA approved technology Registry with minimum 300 patients published in a peer reviewed journal with 0CT subset data. 114 1VL Catheter and Connector Cable,- Intravascular Lithotripsy Intuitive Catheter with Rx system for treating highly calcified lesions,- Integrated 12mm SC balloon, NP -6atm/ RBP - 10 atm, |Diameters:2.5,3.0,3.5,4.0mm,- 2 emitters (120 pulses per catheter) US FDA approved technology Registry with minimum 300 patients published in a peer reviewed journal with OCT subset t data. 115 1VL Catheter and Connector Cable,- Intravascular Lithotripsy Intultive Catheter with Rx system for treating highly calcified lesions,- Integrated 40mm SC balloon,- NP - 6atm/ RBP - 10 atm, Diameters:2.5,3.0,3.5,4.0mm,- 4 emitters (160 pulses per catheter) US FDA approved technology Registry with minimum 300 patients published in a peer reviewed ljournal with 0CT subset data. 116 IVL Catheter and Connector Cable,- Intravascular Lithotripsy Intuitive |Catheter with Rx system for treating highly calcified lesions,- Integrated 60mm SC balloon,- NP - 6atm/ RBP - 10 atm,- Diameters: 3.5,4.0, 4.5, 5.mm, 5.5, 6.0,6.5, 7.0,- 5 emitters (300 pulses per catheter) US FDA approved technology Registry with minimum 300 patients published in a peer reviewed ljournal with OCT subset data. 117 1VL Catheter and Connector Cable,- Intravascular Lithotripsy Intuitive Catheter with Rx system for treating highly calcified lesions,- Integrated 60mm SC balloon,- NP 6atm/ RBP - 10 atm,- Diameter 8mm 5 emitters (300 pulses per catheter) US FDA approved technology Registry with minimum 300 patients published in a peer reviewed ljournal with 0CT subset data. 118 DOC guide wire extension PTFE coated stainless steel attachment desined for ptca procedures featuring a 0.014 diameter and 145cm length 119 Thrombus aspiration catheter with removable core wire and 30cm hydrophilic coating from the Thrombuster II tip; Available in 6F and 7F 120 Semi-complaint PTCA balloon with smallest entry profile of 0.0157, Tapered balloon shape, unique tri-fold wrapping technology, TR2 hydrophilic coating; Available in lowest profile 1 mm |diameter, Longer shaft length of 146cm. 121 Non-compliant PTCA balloon with highest RBP up to 22 ATM; tapered balloon tip to 4mm with lowest shoulder angle to 32 deg: Available in lowest profile 1.5mm diameter, Longer shaft length 122 Paclitaxel Eluting balloon , with wing seal tedchnology, PVP carrier , M3 Drug release technology assorted sizes with EU- MDR Certified
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 25
Uttar Pradesh View Result →
21.
Educational and Research Institute #11307517 Technical Bid
Tender For Ambedkar Gramam Project For Sc Unnathy Pookkunnimala- 1 1) Anganwadi-Civil Works-Ground Floor 2 15.9.2 Demolishing Stone Rubble Masonry Manually / By Mechanical Means Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Metres Lead As Per Direction Of Engineer -In- Charges:In Cement Mortar 3 15.7.4 Demolishing Brick Work Manually / By Mechanical Means Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Metres Lead As Per Direction Of Engineer-In-Charge.In Cement Mortar 4 15.2.2 Demolishing Cement Concrete Manually / By Mechanical Means Including Disposal Of Material Within 50 Metres Lead As Per Direction Of Engineer - In-Charge.Nominal Concrete 1:4:8 Or Leaner Mix ( Including Equivalent Design Mix) 5 15.19 Dismantling Steel Work Manually / By Mechanical Means In Built Up Sections Without Dismembering And Stacking Within 50 Metres Lead As Per Directions Of Engineer -In- Charge. 6 15.28.1 Dismantling Roofing Including Ridges, Hips, Velleys And Gutters Etc., And Stacking The Material Within 50 Metres Lead Of :G.S. Sheet 7 15.13.1 Taking Out Doors, Windows And Clerestory Window Shutters (Steel Or Wood ) Including Stacking Within 50 Metres Lead:Of Area 3 Sq. Metres And Below 8 2.6.1 Earth Work In Excavation By Mechanical Means (Hydraulic Excavator)/Manual Means Over Areas (Exceeding 30 Cm In Depth, 1.5 M In Width As Well As 10 Sqm On Plan) Including Getting Out And Disposal Of Excavated Earth Lead Upto 50 M And Lift Upto 1.5 M, As Directed By Engineer-In-Charge.All Kinds Of Soil 9 4.1.8 Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level:1:4:8 (1 Cement : 4 Coarse Sand (Zone-Iii) Derived From Natural Sources : 8 Graded Stone Aggregate 40 Mm Nominal Size Derived From Natural Sources) 10 5.9.1 Centering And Shuttering Including Strutting, Etc. And Removal Of Form For:Foundations, Footings, Bases Of Columns, Etc For Mass Concrete 11 5.9.5 Centering And Shuttering Including Strutting, Etc. And Removal Of Form For:Lintels, Beams, Plinth Beams, Girders Bressumers And Cantilevers 12 5.9.6 Centering And Shuttering Including Strutting, Etc. And Removal Of Form For:Columns, Pillars, Piers, Abutments, Posts And Struts 13 5.1.2 Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement - All Work Up To Plinth Level:1:1:5:3 (1 Cement 1.5 Coarse Sand :3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources) 14 5.2.2 Reinforced Cement Concrete Work In Walls (Any Thickness), Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc. Up Tot Floor Five Level Excluding Cost Of Centering, Shuttering, Finishing And Reinforcement :1:1.5:3( 1 Cement : 1.5 Coarse Sand : 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources) 15 5.9.3 Centering And Shuttering Including Strutting, Etc. And Removal Of Form For:Suspended Floors, Roofs, Landings, Balconies And Access Platform 16 5.3 Reinforced Cement Concrete Work In Beams, Suspended Floors, Roofs, Having Slope Up To 15° Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Window Sills, Staircases And Spiral Stair Cases Up To Floor Five Level Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement, With1:1.5:3 (1 Cement : 1.5 Coarse Sand (Zone Iii) Derived From Natural Sources: 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources). 17 5.22.6 Steel Reinforcement For R.C.C Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Upto Plinth Levelthermo - Mechanically Treated Bars Of Grade Fe-500D Or More 18 2.25 Filling Available Excavated Earth (Excluding Rock) In Trenches, Plinth, Sides Of Foundation Etc. In Layers Not Exceeding 20 Cm In Depth, Consolidating Each Deposited Layer By Ramming And Watering, Lead Up To 50 M And Lift Up To 1.5 M. 19 50.6.1.2 Solid Block Masonry Using Pre Cast Solid Blocks (Factory Made) Of Size 40X20X20Cm Or Nearest Available Size Confirming To Is 2185 Part I Of 1979 For Super Structure Up To Floor Two Level Thickness 20Cm And Above In: Cm 1:6 ( 1 Cement: 6 Coarse Sand) Etc Complete. 20 13.7.1 12 Mm Cement Plaster Finished With A Floating Coat Of Neat Cement Of Mix:1:3 ( 1 Cement : 3 Fine Sand) 21 13.1.1 12 Mm Cement Plaster Of Mix:1:4 ( 1 Cement : 4 Fine Sand) 22 50.9.1.1 Providing Wood Work In Frames Of Doors, Windows, Clerestory Windows And Other Frames, Wrought Framed And Fixed In Position With Hold Fast Lugs Or With Dash Fasteners Of Required Dia & Length (Hold Fast Lugs Or Dash Fastener Shall Be Paid For Separately), Using Good Quality Anjili Wood /Jack Wood 23 50.9.2.1 Providing And Fixing Paneled And Glazed Shutters For Doors, Windows And Clerestory Windows, 35 Mm Thick Shutters Including Isi Marked M.S. Pressed Butt Hinges Bright Finished Of Required Size With Necessary Screws, Excluding Panelling Which Will Bepaid For Separately, All Complete As Per Direction Of Engineerin - Charge Using Anjili/ Jack Wood 24 50.9.6.1 Providing And Fixing Glazed Shutters For Doors, Windows And Clerestory Windows Using 4 Mm Thick Float Glass Panes Including Isi Marked M.S. Pressed Butt Hinges Bright Finished Of Required Size With Necessary Screws. Using Anjili Wood / Jack Wood 30 Mm Thick Shutters 25 14.29 Providing And Fixing M.S. Round Or Squre Bars With M.S. Flats At Required Spacing In Wooden Frames Of Windows And Clerestory Windows. 26 10.27.5 Providing And Fixing Carbon Steel Galvanised ( Minimum Coating 5 Micron) Dash Fastener Of 10 Mm Dia Double Threaded 6.8 Grade (Yield Strength 480 N/Mm2), Counter Sunk Head, Comprising Of 10 M Dia Polyamide P A 6 Grade Sleeve, Including Drilling Of Hole In Frame, Concrete/Masonry, Etc. As Per Direction Of Engineer-In-Charge.10X 160 Mm 27 9.76 Providing And Fixing Bright Finished Brass 100 Mm Mortice Latch And Lock With 6 Levers And A Pair Of Lever Handles Of Approved Quality With Necessary Screws Etc. Complete. 28 9.92.1 Providing And Fixing Chromium Plated Brass Handles With Necessary Screws Etc. Complete:125 Mm 29 9.74.3 Providing And Fixing Bright Finished Brass Tower Bolts (Barrel Type) With Necessary Screws Etc. Complete:150X10 Mm 30 9.83 Providing And Fixing Aluminium Die Cast Body Tubular Type Universal Hydraulic Door Closer (Having Brand Logo With Isi, Is : 3564, Embossed On The Body, Door Weight Upto 35 Kg And Door Width Upto 700 Mm), With Necessary Accessories And Screws Etc. Complete. 31 Od123879/2025-2026 Providing And Fixing Frp (Fibre Reinforced Polymer) Door Shutter Of Size 90Cm And 28-30Mm Thickness With Frame 110Mm Thickness With Necessary Fittings Like Hinges, Cost Index (Place) : Kollam, Gst : 18% Printed On 2026-03-17 13:56:12.13 4 Including All Materials And Labour Charge Etc As Per The Direction Of Engineer In Charge 32 Od123885/2025-2026 Providing And Fixing Frp (Fibre Reinforced Polymer) Door Shutter Of Size 80Cm And 28-30Mm Thickness With Frame 110Mm Thickness With Necessary Fittings Like Hinges, Tower Bolts, Handles, Mortice/Cylindrical Locks And All Other Accessories Etc. Complete Including All Materials And Labour Charge Etc As Per The Direction Of Engineer In Charge 33 11.41.2 Providing And Laying Vitrified Floor Tiles In Different Sizes (Thickness To Be Specified By The Manufacturer) With Water Absorption Less Than 0.08% And Conforming To Is : 15622, Of Approved Make, In All Colours And Shades, Laid On 20 Mm Thick Cement Mortar 1:4(1 Cement : 4 Coarse Sand), Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete.Size Of Tile 600 X 600 Mm. 34 11.46.2 Providing And Laying Vitrified Tiles Indifferent Sizes (Thickness To Be Specified By Manufacturer), With Water Absorption Less Than 0.08 % And Conforming To I.S. 15622, Of Approved Make, In All Colours & Shade, In Skirting, Riser Of Steps, Over 12 Mm Thick Bed Of Cement Mortar 1:3 (1 Cement : 3 Coarse Sand), Including Grouting The Joint With White Cement & Matching Pigments Etc. Complete.Size Of Tile 600X600 Mm 35 11.37 Providing And Laying Ceramic Glazed Floor Tiles Of Size 300X300 Mm (Thickness To Be Specified By The Manufacturer) Of 1St Quality Conforming To Is : 15622 Of Approved Make In Colours Such As White, Ivory, Grey, Fume Red Brown, Laid On 20 Mm Thick Cement Mortar 1:4 (1 Cement : 4 Coarse Sand), Jointing With Grey Cement Slurry @ 3.3 Kg/Sqm Including Pointing The Joints With White Cement And Matching Pigment Etc., Complete 36 8.31 Providing And Fixing Ist Quality Ceramic Glazed Wall Tiles Conforming To Is: 15622 (Thickness To Be Specified By The Manufacturer), Of Approved Make, In All Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Engineer-In- Charge, In Skirting, Risers Of Steps And Dados, Over 12 Mm Thick Bed Of Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) And Jointing With Grey Cement Slurry @ 3.3Kg Per Sqm, Including Pointing In White Cement Mixed With Pigment Of Matching Shade Complete. 37 11.16.1 Precast Terrazo Tiles 22 Mm Thick With Graded Marble Chips Of Size Upto 12Mm, Laid In Floors, And Landings, Jointed With Neat Cement Slurry Mixed With Pigment To Match The Shade Of The Tiles Including Rubbing And Polishing Complete, On 20 Mm Thick Bed Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) :Light Shade Pigment Using White Cement 38 8.2.2.2 Providing And Fixing 18 Mm Thick Gang Saw Cut, Mirror, Polished, Premoulded And Prepolished, Machine Cut For Kitchen Platforms, Vanity Counters, Window Sills, Facias And Similar Locations, Of Required Size, Approved Shade, Colour And Texture Laid Over 20 Mm Thick Base Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand), Joints Treated With White Cement, Mixed With Matching Pigment, Epoxy Touch Ups, Including Rubbing, Curing, Moulding And Polishing To Edges To Give High Gloss Finish Etc. Complete At All Levels.Area Of Slab Over 0.50 Sqm 39 8.3.2 Providing Edge Moulding To 18 Mm Thick Marble Stone Counters, Vanities Etc., Including Machine Polishing To Edge To Give High Gloss Finish Etc. Complete As Per Design Approved By Engineer -In-Charge.Granite Work 40 13.80 Providing And Applying White Cement Based Putty Of Average Thickness 1 Mm, Of Approved Brand And Manufacturer, Over The Plastered Wall Surface To Prepare The Surface Even And Smooth Complete. 41 13.43.1 Applying One Coat Of Water Thinnable Cement Primer Of Approved Brand And Manufacture On Wall Surface:Water Thinnable Cement Primer 42 13.60.1 Wall Painting With Acrylic Emulsion Paint Of Approved Brand And Manufacture To Give An Even Shade:Two Or More Coats On New Work 43 13.47.1 Finishing Walls With Premium Acrylic Smooth Exterior Paint With Silicone Additives Of Required Shade:New Work (Two Or More Coats Applied @ 1.43 Ltr/ 10 Sqm Over And Including Priming Coat Of Exterior Primer Applied @ 2.20 Kg/ 10 Sqm) 44 13.85.1 Applying Priming Coats With Primer Of Approved Brand And Manufacture, Having Low Voc ( Volatile Organic Compound) Content.With Ready Mixed Pink Or Grey Primer On Wood Work (Hard And Soft Wood ) Having Voc Content Less Than 50 Grams/ Litre 45 13.61.1 Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture To Give An Even Shade:Two Or More Coats On New Work 46 10.28 Providing And Fixing Stainless Steel (Grade 304) Railing Made Of Hollow Tubes, Channels, Plates Etc., Including Welding, Grinding, Buffing, Polishing And Making Curvature (Wherever Required) And Fitting The Same With Necessary Stainless Steel Nuts And Bolts Complete, I/C Fixing The Railing With Necessary Accessories & Stainless Steel Dash Fasteners, Stainless Steel Bolts Etc., Of Required Size On The Top Of The Floor Or The Side Of Waist Slab With Suitable Arrangement As Per Approval Of Engineer-In-Charge, (For Payment Purpose Only Weight Of Stainless Steel Members Shall Be Considered Excluding Fixing Accessories Such As Nuts, Bolts, Fasteners Etc.) 47 Od134882/2025-2026 Supplying And Fixing Anganwadi/Library/Vignjaanwadi Name Board With Emblem Using Acrylic Sheet Base With Reflective Type Sticker As Per Required Shade And Color Etc Complete. Size Of Board 3.00Mx 0.60M 48 Od134893/2025-2026 Providing And Fixing Anganwadi/Library/Vignjaanwadi -Foundation Stone/Inauguration Stone Using Granite Of Size 70.00X135.00 Cm ,18Mm Thick With Writing Letters In Golden Colour Including Of All Material And Labour Charges Etc. Complete As Per The Directions Of Engineer-In-Charge. 49 2.1.1 Earth Work In Surface Excavation Not Exceeding 30 Cm In Depth But Exceeding 1.5M In Width As Well As 10 Sqm On Plan Including Disposal Of Excavated Earth Up To 50 M And Lift Up To 1.5 M, Disposed Soil To Be Levelled And Neatly Dressed:All Kinds Of Soil 50 16.68 Providing And Laying 60 Mm Thick Factory Made Cement Concrete Interlocking Paver Block Of M - 30 Grade Made By Block Making Machine With Strong Vibratory Compaction, Of Approved Size, Design & Shape, Laid In Required Colour And Pattern Over And Including 50 Mm Thick Compacted Bed Of Coarse Sand, Filling The Joints With Fine Sand Etc. All Complete As Per The Direction Of Engineer-In-Charge. 51 50.10.1 Steel Work In Built Up G I Tubular ( Round, Square Or Rectangular Hollow Tubes Etc.) Trusses Etc., Including Cutting, Hoisting,Fixing In Position And Applying A Priming Coat Of Approved Steel Primer, Including Welding And Bolted With Special Shaped Washers Etc. Complete 52 50.10.2 Steel Work For Purlin/Single Section With G I Pipes Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer, Including Welding And Bolted With Special Shaped Washers Etc. Complete 53 12.50 Providing And Fixing Precoated Galvanised Iron Profile Sheets (Size, Shape And Pitch Of Corrugation As Approved By Engineer-In-Charge) 0.50 Mm (+0.05%), Total Coated Thickness With Zinc Coating 120 Grams Per Sqm As Per Is: 277, In 240 Mpa Steel Grade, 5-7 Microns Epoxy Primer On Both Side Of The Sheet And Polyester Top Coat 15-18 Microns. Sheet Should Have Protective Guard Film Of 25 Microns Minimum To Avoid Scratches During Transportation And Should Be Supplied In Single Length Upto 12 Metre Or As Desired By Engineer-In-Charge. The Sheet Shall Be Fixed Using Self Drilling/Self Tapping Screws Of Size (5.5X55Mm) With Epdm Seal, Complete Upto Any Pitch In Horizontal/ Vertical Or Curved Surfaces, Excluding The Cost Of Purlins, Rafters And Trusses And Including Cutting To Size And Shape Wherever Required. 54 12.51.1 Providing And Fixing Precoated Galvanised Steel Sheet Roofing Accessories 0.50 Mm (+0.05 %) Total Coated Thickness, Zinc Coating 120 Grams Per Sqm As Per Is: 277, In 240 Mpa Steel Grade, 5-7 Microns Epoxy Primer On Both Side Of The Sheet And Polyester Top Coat 15-18 Microns Using Self Drilling/ Self Tapping Screwscomplete :Ridges Plain (500-600 Mm) 55 Od141946/2025-2026 Providing And Fixing 8 Upvc Aqua Pathy ( Gutter) With M.S Clamp All Complete As Per Direction Of Engineer-In-Charge. 56 1)Vignjaanwadi,Library Cum Reading Room-First Floor 57 5.9.6 Centering And Shuttering Including Strutting, Etc. And Removal Of Form For:Columns, Pillars, Piers, Abutments, Posts And Struts 58 5.9.5 Centering And Shuttering Including Strutting, Etc. And Removal Of Form For:Lintels, Beams, Plinth Beams, Girders Bressumers And Cantilevers 59 5.2.2 Reinforced Cement Concrete Work In Walls (Any Thickness), Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc. Up Tot Floor Five Level Excluding Cost Of Centering, Shuttering, Finishing And Reinforcement :1:1.5:3( 1 Cement : 1.5 Coarse Sand : 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources) 60 5.9.3 Centering And Shuttering Including Strutting, Etc. And Removal Of Form For:Suspended Floors, Roofs, Landings, Balconies And Access Platform 61 5.3 Reinforced Cement Concrete Work In Beams, Suspended Floors, Roofs, Having Slope Up To 15° Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Window Sills, Staircases And Spiral Stair Cases Up To Floor Five Level Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement, With1:1.5:3 (1 Cement : 1.5 Coarse Sand (Zone Iii) Derived From Natural Sources: 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources). 62 5.22.6 Steel Reinforcement For R.C.C Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Upto Plinth Levelthermo - Mechanically Treated Bars Of Grade Fe-500D Or More 63 50.6.1.2 Solid Block Masonry Using Pre Cast Solid Blocks (Factory Made) Of Size 40X20X20Cm Or Nearest Available Size Confirming To Is 2185 Part I Of 1979 For Super Structure Up To Floor Two Level Thickness 20Cm And Above In: Cm 1:6 ( 1 Cement: 6 Coarse Sand) Etc Complete. 64 13.7.1 12 Mm Cement Plaster Finished With A Floating Coat Of Neat Cement Of Mix:1:3 ( 1 Cement : 3 Fine Sand) 65 13.1.1 12 Mm Cement Plaster Of Mix:1:4 ( 1 Cement : 4 Fine Sand) 66 13.4.1 12 Mm Cement Plaster Of Mix:1:4 ( 1 Cement : 4 Coarse Sand) 67 50.9.1.1 Providing Wood Work In Frames Of Doors, Windows, Clerestory Windows And Other Frames, Wrought Framed And Fixed In Position With Hold Fast Lugs Or With Dash Fasteners Of Required Dia & Length (Hold Fast Lugs Or Dash Fastener Shall Be Paid For Separately), Using Good Quality Anjili Wood /Jack Wood 68 50.9.2.1 Providing And Fixing Paneled And Glazed Shutters For Doors, Windows And Clerestory Windows, 35 Mm Thick Shutters Including Isi Marked M.S. Pressed Butt Hinges Bright Cost Index (Place) : Kollam, Gst : 18% Printed On 2026-03-17 13:56:12.13 9 Paid For Separately, All Complete As Per Direction Of Engineerin - Charge Using Anjili/ Jack Wood 69 50.9.6.1 Providing And Fixing Glazed Shutters For Doors, Windows And Clerestory Windows Using 4 Mm Thick Float Glass Panes Including Isi Marked M.S. Pressed Butt Hinges Bright Finished Of Required Size With Necessary Screws. Using Anjili Wood / Jack Wood 30 Mm Thick Shutters 70 14.29 Providing And Fixing M.S. Round Or Squre Bars With M.S. Flats At Required Spacing In Wooden Frames Of Windows And Clerestory Windows. 71 10.27.5 Providing And Fixing Carbon Steel Galvanised ( Minimum Coating 5 Micron) Dash Fastener Of 10 Mm Dia Double Threaded 6.8 Grade (Yield Strength 480 N/Mm2), Counter Sunk Head, Comprising Of 10 M Dia Polyamide P A 6 Grade Sleeve, Including Drilling Of Hole In Frame, Concrete/Masonry, Etc. As Per Direction Of Engineer-In-Charge.10X 160 Mm 72 9.76 Providing And Fixing Bright Finished Brass 100 Mm Mortice Latch And Lock With 6 Levers And A Pair Of Lever Handles Of Approved Quality With Necessary Screws Etc. Complete. 73 9.92.1 Providing And Fixing Chromium Plated Brass Handles With Necessary Screws Etc. Complete:125 Mm 74 9.74.3 Providing And Fixing Bright Finished Brass Tower Bolts (Barrel Type) With Necessary Screws Etc. Complete:150X10 Mm 75 9.83 Providing And Fixing Aluminium Die Cast Body Tubular Type Universal Hydraulic Door Closer (Having Brand Logo With Isi, Is : 3564, Embossed On The Body, Door Weight Upto 35 Kg And Door Width Upto 700 Mm), With Necessary Accessories And Screws Etc. Complete. 76 Od127305/2025-2026 Providing And Fixing Frp (Fibre Reinforced Polymer) Door Shutter Of Size 80Cm 28-30Mm Thickness With Frame And Tower Bolts, Handles, Mortice/Cylindrical Locks And All Other Accessories Etc. Complete Including All Materials And Labour Charge Etc As Per The Direction Of Engineer In Charge 77 Od126510/2025-2026 Providing And Fixing Frp (Fibre Reinforced Polymer) Door Shutter Of Size 90Cm And 28-30Mm Thickness With Frame 110Mm Thickness With Necessary Fittings Like Hinges, Tower Bolts, Handles, Mortice/Cylindrical Locks And All Other Accessories Etc. Complete Including All Materials And Labour Charge Etc As Per The Direction Of Engineer In Charge 78 11.41.2 Providing And Laying Vitrified Floor Tiles In Different Sizes (Thickness To Be Specified By The Manufacturer) With Water Absorption Less Than 0.08% And Conforming To Is : 15622, Of Approved Make, In All Colours And Shades, Laid On 20 Mm Thick Cement Mortar 1:4(1 Cement : 4 Coarse Sand), Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete.Size Of Tile 600 X 600 Mm. 79 11.46.2 Providing And Laying Vitrified Tiles Indifferent Sizes (Thickness To Be Specified By Manufacturer), With Water Absorption Less Than 0.08 % And Conforming To I.S. 15622, Of Approved Make, In All Colours & Shade, In Skirting, Riser Of Steps, Over 12 Mm Thick Bed Of Cement Mortar 1:3 (1 Cement : 3 Coarse Sand), Including Grouting The Joint With White Cement & Matching Pigments Etc. Complete.Size Of Tile 600X600 Mm 80 11.37 Providing And Laying Ceramic Glazed Floor Tiles Of Size 300X300 Mm (Thickness To Be Specified By The Manufacturer) Of 1St Quality Conforming To Is : 15622 Of Approved Make In Colours Such As White, Ivory, Grey, Fume Red Brown, Laid On 20 Mm Thick Cement Mortar 1:4 (1 Cement : 4 Coarse Sand), Jointing With Grey Cement Slurry @ 3.3 Kg/Sqm Including Pointing The Joints With White Cement And Matching Pigment Etc., Complete 81 8.31 Providing And Fixing Ist Quality Ceramic Glazed Wall Tiles Conforming To Is: 15622 (Thickness To Be Specified By The Manufacturer), Of Approved Make, In All Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Engineer-In- Charge, In Skirting, Risers Of Steps And Dados, Over 12 Mm Thick Bed Of Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) And Jointing With Grey Cement Slurry @ 3.3Kg Per Sqm, Including Pointing In White Cement Mixed With Pigment Of Matching Shade Complete. 82 13.80 Providing And Applying White Cement Based Putty Of Average Thickness 1 Mm, Of Approved Brand And Manufacturer, Over The Plastered Wall Surface To Prepare The Surface Even And Smooth Complete. 83 13.43.1 Applying One Coat Of Water Thinnable Cement Primer Of Approved Brand And Manufacture On Wall Surface:Water Thinnable Cement Primer 84 13.60.1 Wall Painting With Acrylic Emulsion Paint Of Approved Brand And Manufacture To Give An Even Shade:Two Or More Coats On New Work 85 13.47.1 Finishing Walls With Premium Acrylic Smooth Exterior Paint With Silicone Additives Of Required Shade:New Work (Two Or More Coats Applied @ 1.43 Ltr/ 10 Sqm Over And Including Priming Coat Of Exterior Primer Applied @ 2.20 Kg/ 10 Sqm) 86 13.85.1 Applying Priming Coats With Primer Of Approved Brand And Manufacture, Having Low Voc ( Volatile Organic Compound) Content.With Ready Mixed Pink Or Grey Primer On Wood Work (Hard And Soft Wood ) Having Voc Content Less Than 50 Grams/ Litre 87 13.61.1 Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture To Give An Even Shade:Two Or More Coats On New Work 88 10.28 Providing And Fixing Stainless Steel (Grade 304) Railing Made Of Hollow Tubes, Channels, Plates Etc., Including Welding, Grinding, Buffing, Polishing And Making Curvature (Wherever Required) And Fitting The Same With Necessary Stainless Steel Nuts And Bolts Complete, I/C Fixing The Railing With Necessary Accessories & Stainless Steel Dash Fasteners, Stainless Steel Bolts Etc., Of Required Size On The Top Of The Floor Or The Side Of Waist Slab With Suitable Arrangement As Per Approval Of Engineer-In-Charge, (For Payment Purpose Only Weight Of Stainless Steel Members Shall Be Considered Excluding Fixing Accessories Such As Nuts, Bolts, Fasteners Etc.) 89 Od135395/2025-2026 Supplying And Fixing Anganwadi/Library/Vignjaanwadi Name Board With Emblem Using Acrylic Sheet Base With Reflective Type Sticker As Per Required Shade And Color Etc Complete. Size Of Board 3.00Mx 0.60M 90 1)Plumbing Works -Ground Floor & First Floor 91 17.3.2 Providing And Fixing White Vitreous China Pedestal Type Water Closet Bend With Fittings & C.I. Brackets, 40 Mm Flush Bend, Overflow Arrangement With Specials Of Standard Make And Mosquito Proof Coupling Of Approved Municipal Design Complete, Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls And Floors Wherever Required :W.C. Pan With Isi Marked Black Solid Plastic Seat And Lid 92 50.17.1.5 Supplying And Fixing Cp Health Faucet Superior Quality ( Jagur Or Equvalent Make ) Including Cost Of Materials And Labour Charges Etc Complete As Per The Direction Of Site Engineer-In-Charge. 93 17.7.2 Providing And Fixing Wash Basin With C.I. Brackets, 15 Mm C.P. Brass Pillar Taps, 32 Mm C.P. Brass Waste Of Standard Pattern, Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls Wherever Require:White Vitreous China Wash Basin Size 630 X 450 Mm With A Single 15 Mm C.P. Brass Pillar Tap 94 17.9.1 Providing And Fixing Kitchen Sink With C. I Brackets, C.P. Brass Chain With Rubber Plug, 40 Mm C.P Brass Waste Complete, Including Painting The Fittings And Brackets, Cutting And Making Good The Walls Wherever Required:White Glazed Fire Clay Kitchen Sink Of Size 600X450X250 Mm 95 18.53.1 Providing And Fixing C.P. Brass Angle Valve For Basin Mixer And Geyser Points Of Approved Quality Conforming To Is: 893115 Mm Nominal Bore 96 18.32.1 Constructing Masonry Chamber 30X30X50 Cm Inside, In Brick Work In Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) For Stop Cock, With C.I. Surface Box 100X100X75 Mm (Inside) With Hinged Cover Fixed In Cement Concrete Slab 1:2:4 Mix (1 Cement : 2 Coarse Sand: 4 Graded Stone Aggregate 20 Mm Nominal Size), I/C Necessary Excavation, Foundation Concrete 1:5:10 (1 Cement : 5 Fine Sand : 10 Graded Stone Aggregate 40 Mm Nominal Size) And Inside Plastering With Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) 12 Mm Thick, Finished With A Floating Coat Of Neat Cement Complete As Per Standard Design:With Common Burnt Clay F.P.S (Non Modular) Bricks Of Class Designation 7.5 97 17.73.2 Providing And Fixing Ptmt Towel Rail Complete With Brackets Fixed To Wooden Cleats With Cp Brass Screws With Concealed Fitting Arrangement Of Approved Quality And Colour600 Mm Long Towel Rail With Total Length Of 645 Mm, Width 78 Mm And Effective Height Of 88 Mm, Weighting Not Less Than 190 Gms 98 18.51.1 Providing And Fixing C.P. Brass Long Body Bib Cock Of Approved Quality Conforming To Is Standards And Weighing Not Less Than 690 Gms.15 Mm Nominal Bore 99 50.18.7.2.1 Providing And Fixing Pvc Pipes, Fittings Including Fixing The Pipe With Claps At 1.00 Metre Spacing. This Includes Jointing Of Pipes & Fittings With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer-In-Charge 20 Mm Dia 12Kgf/Cm2 - Internal Work - Exposed On Wall 100 50.18.9.3.2 Providing And Fixing Pvc Pipes Includes Jointing Of Pipes With One Step Pvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineer In Charge. 25 Mm Dia 10Kgf/Cm2 101 50.18.7.6.1 Providing And Fixing Pvc Pipes, Fittings Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer-In-Charge 50 Mm Dia 10 Kfg/Cm - Internal Work- Exposed On Wall 102 50.18.9.7.1 Providing And Fixing Pvc Pipes Includings Of Pipes With One Step Pvc Solvent Cement, Trenching Refilling & Testing Of Joints Complete As Per Direction Of Engineer In Charge. 63 Mm Dia 6Kgf/Cm3 103 50.18.9.9.1 Providing And Fixing Pvc Pipes Includings Jointing Of Pipes With One Step Pvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineer In Charge.110 Mm Dia 6Kgf/Cm2 104 50.18.9.22.1 Providing And Fixing Pvc Moulded Fittings/ Accessories For Rigid Pvc Pipes, Including Jointing With Pvc Solvent Cement - 110 Mm Dia Elbow 105 50.18.9.22.2 Providing And Fixing Pvc Moulded Fittings / Accessories For Rigid Pvc Pipes, Including Jointing With Pvc Solvent Cement - 110 Mm Dia 45 Degree Elbow 106 50.18.9.22.4 Providing And Fixing Pvc Moulded Fittings/ Accessories For Rigid Pvc Pipes, Including Jointing With Pvc Solvent Cement- 110 Mm Dia Bend 107 50.18.9.22.5 Providing And Fixing Pvc Moulded Fittings/ Accessories For Rigid Pvc Pipes Including Jointing With Pvc Solvent Cement 110X110X110 Mm Dia Tee 108 50.18.9.22.7 Providing And Fixing Pvc Moulded Fittings/ Accessories For Rigid Pvc Pipes, Including Jointing With Pvc Solvent Cement - 110X110X75 Mm Dia Door Tee 109 18.58.2.1 Providing And Fixing Ptmt Grating Of Approved Quality And Colour. Rectangular Type With Openable Circular Lid150 Mm Nominal Size Square 100 Mm Diameter Of The Inner Hinged Round Grating 110 51.19.St4 Supplying And Installing Ready Made Pvc Septic Tank Including The Cost Of Carriage, Trenching, Placing At The Level Below Ground Level As Specified As Per The Direction Of Engineer In Charge (Provision For Cc/Rcc/Sand/06Mm Aggregate For The Preparation Of Bed Shall Be Paid Separately) 4. 35 To 50 Flush Capacity 111 18.48 Providing And Placing On Terrace (At All Floor Levels) Polyethylene Water Storage Tank :Isi 12701 Marked, With Cover And Suitable Locking Arrangement And Making Necessary Holes For Inlet, Outlet And Overflow Pipes But Without Fittings And The Base Support For Tank. 112 Od141980/2025-2026 Providing 25Mm/32Mm (3/4 Inch/1 Inch) Public Building Connection With 20Mm (3/4 Inch) Water Meter From Existing Ci Mains Up To 125 Mm Dia., Up To A Length Of 5 M Using 25Mm Indian Standard Class 6 Upvc Pipe And Upvc / Gm / Brass Specials Viz. Brass Ferrule, Gm Full Way Wheel Valve, Elbow, Mta, Fta, Couplers Etc. And Connecting With The Mains, Testing The Joints Etc. Complete Including Trenching And Refilling In All Kinds Of Soil Up To A Depth Of 1.50M For Main Line Tracing And Trench Of Average Cross Section 0.3M X 0.75M For Laying Connection Pipe And Service Pipe, Fixing Water Meter, Lighting, Watching, Providing Caution Boards, Traffic Control Etc. Complete Including Cost Of Materials, Hire For Tools, Cost Of Consumables And Labour Charges , Cost Of Water Meter And Meter Box, Deposit Charges Of Kwa And Including Charges For Cutting The Concrete / Tarred / Bituminous Roads Etc, If Necessary And As Per The Direction Of The Engineer-In-Charge. 113 1)Electrical Works -Ground Floor & First Floor 114 1.10.3 Wiring For Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Medium Class Pvc Conduit, With Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm. Frls Pvc Insulated Copper Conductor Single Core Cable Etc As Required.Group C 115 1.14.2 Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Medium Class Pvc Conduit As Required2X 2.5 Sq. Mm + 1 X 2.5 Sq. Mm Earth Wire 116 1.23.4 Supplying And Fixing Following Piano Type Switch / Socket On The Existing Switch Box/ Cover Including Connections Etc. As Required.3 Pin 5/6 Amp Socket Outlet 117 1.24.3 Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required.15/16 Amp Switch 118 1.24.5 Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required.6 Pin 15/16 Amp Socket Outlet 119 1.12 Wiring For Light/ Power Plug With 2X4 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface/ Recessed Medium Class Pvc Conduit Along With 1 No 4 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable For Loop Earthing As Required. 120 2.3.3 Supplying And Fixing Following Way, Single Pole And Neutral, Sheet Steel, Mcb Distribution Board, 240 Volts, On Surface/ Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Including Earthing Etc. As Required. (But Without Mcb/Rccb/Isolator) 12 Way, Double Door 121 1.25 Supplying And Fixing Two Module Stepped Type Electronic Fan Regulator On The Existing Modular Plate Switch Box Including Connections But Excluding Modular Plate Etc. As Required. 122 5.4 Earthing With G.I. Earth Plate 600 Mm X 600 Mm X 6 Mm Thick Including Accessories, And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Of 2.7 Metre Long Etc. With Charcoal/ Coke And Salt As Required. 123 5.19 Providing And Fixing 4.00 Mm Dia Copper Wire On Surface Or In Recess For Loop Earthing Along With Existing Surface/ Recessed Conduit/ Submain Wiring/ Cable As Required. 124 1.27.2 Supplying And Fixing Following Size/ Modules, Gi Box Alongwith Modular Base & Cover Plate For Modular Switches In Recess Etc As Required.3 Module (100Mmx75Mm) 125 2.14.2 Supplying And Fixing Following Rating, Double Pole, (Single Phase And Neutral),240 Volts, Residual Current Circuit Breaker (Rccb), Having A Sensitivity Current 30 Milli Amperes In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 40 Amps 126 2.10.1 Supplying And Fixing 5A To 32 A Rating, 240/415 Volts, 10 Ka, \\C\\ Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. Single Pole 127 1.14.1 Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Medium Class Pvc Conduit As Required2X1.5 Sq.Mm + 1X1.5 Sq.Mm Earth Wire 128 2.12.1 Supplying And Fixing Following Rating, Double Pole, 240 Volts, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.40 Amps 129 Od123876/2025-2026 Supplying And Fixing Following 32 Amps Modular Dp Switch And Other Accessories Etc Complete 130 Od123878/2025-2026 Supplying And Fixing 14 W Led Connect With Bulk Head Fixing And Other Accessories 131 Od123874/2025-2026 Supply And Fixing Angle Batten With 7/9 Watts Led And Other Accessories 132 Od123877/2025-2026 Supply And Fixing Angle Batten With 14/15 Watts Led And Other Accessories 133 Od123872/2025-2026 Supplying And Fixing 20W Led Tube Set (Approved Brands) And Other Accessories 134 90.4.5.4 Supply, Installation, Testing And Commissioning Of Ceiling Fan Of Following Sizes Including Wiring The Down Rods Of Standard Length (Up To 30 Cm) With 1.5 Sq. Mm Frls Pvc Insulated, Copper Conductor, Single Core Cable Etc. As Required. 1200Mm Sweep - Ceiling Fan Complete With Service Value Minimum 4.0(Cub Meter/Minute/Watt), Air Delivery Minimum 210(Cubic Meter/Minute), Copper Winding Suitable For 230V/240V Single Phase Ac Supply 135 Od123875/2025-2026 Supplying, Installing, Testing And Commissioning Of Wall Mounted Single Phase 2 Wire Energy Meter With Meter Box Poly Carbonate Body Having Range Of 32 Amp With Enclosure Made Out Of Powder Coated 16 Swg Sheet Suitable For Fixing In Surface/ Recess With Fuse Unit 32 Amp With Neutral Link, Its Interconnection Etc. The Enclosure Shall Have Lockable Door With Glass Window And All Mounting Accessories Etc. Complete As Required Including Kseb Charges 136 2)Childrens Play Equipments 137 Od135736/2025-2026 Supply And Fixing ChildrenS Play Equipment Circular See-Saw Including Cost Of All Materials And Labour Charges Etc Complete. 138 Od135738/2025-2026 Supplying And Fixing ChildrenS Play Equipment Step With Slide Including Cost Of All Materials And Labour Charges, Etc. 139 3)Community Hall-Renovation-Civil Works 140 15.28.1 Dismantling Roofing Including Ridges, Hips, Velleys And Gutters Etc., And Stacking The Material Within 50 Metres Lead Of :G.S. Sheet 141 15.19 Dismantling Steel Work Manually / By Mechanical Means In Built Up Sections Without Dismembering And Stacking Within 50 Metres Lead As Per Directions Of Engineer -In- Charge. 142 15.2.2 Demolishing Cement Concrete Manually / By Mechanical Means Including Disposal Of Material Within 50 Metres Lead As Per Direction Of Engineer - In-Charge.Nominal Concrete 1:4:8 Or Leaner Mix ( Including Equivalent Design Mix) 143 13.33.1 Pointing On Stone Work With Cement Mortar 1:3 ( 1 Cement : 3 Fine Sand):Flush/ Ruled Pointing 144 5.1.2 Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement - All Work Up To Plinth Level:1:1:5:3 (1 Cement 1.5 Coarse Sand :3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources) 145 11.41.2 Providing And Laying Vitrified Floor Tiles In Different Sizes (Thickness To Be Specified By The Manufacturer) With Water Absorption Less Than 0.08% And Conforming To Is : 15622, Of Approved Make, In All Colours And Shades, Laid On 20 Mm Thick Cement Mortar 1:4(1 Cement : 4 Coarse Sand), Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete.Size Of Tile 600 X 600 Mm. 146 13.1.1 12 Mm Cement Plaster Of Mix:1:4 ( 1 Cement : 4 Fine Sand) 147 13.91 Removing Dry Or Oil Bound Distemper, Water Proofing Cement Paint And The Like By Scrapping, Sand Papering And Preparing The Surface Smooth Including Necessary Repairs To Scratches Etc. Complete 148 13.43.1 Applying One Coat Of Water Thinnable Cement Primer Of Approved Brand And Manufacture On Wall Surface:Water Thinnable Cement Primer 149 13.60.1 Wall Painting With Acrylic Emulsion Paint Of Approved Brand And Manufacture To Give An Even Shade:Two Or More Coats On New Work 150 13.47.1 Finishing Walls With Premium Acrylic Smooth Exterior Paint With Silicone Additives Of Required Shade:New Work (Two Or More Coats Applied @ 1.43 Ltr/ 10 Sqm Over And Including Priming Coat Of Exterior Primer Applied @ 2.20 Kg/ 10 Sqm) 151 13.88 Removing White Or Colour Wash By Scrapping And Sand Papering And Preparing The Surface Smooth Including Necessary Repairs To Scratches Etc. Complete. 152 13.85.1 Applying Priming Coats With Primer Of Approved Brand And Manufacture, Having Low Voc ( Volatile Organic Compound) Content.With Ready Mixed Pink Or Grey Primer On Wood Work (Hard And Soft Wood ) Having Voc Content Less Than 50 Grams/ Litre 153 13.99.1 Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture Of Required Colour To Give An Even Shade :One Or More Coats On Old Work 154 50.10.1 Steel Work In Built Up G I Tubular ( Round, Square Or Rectangular Hollow Tubes Etc.) Trusses Etc., Including Cutting, Hoisting,Fixing In Position And Applying A Priming Coat Of Approved Steel Primer, Including Welding And Bolted With Special Shaped Washers Etc. Complete 155 50.10.2 Steel Work For Purlin/Single Section With G I Pipes Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer, Including Welding And Bolted With Special Shaped Washers Etc. Complete 156 12.50 Providing And Fixing Precoated Galvanised Iron Profile Sheets (Size, Shape And Pitch Of Cost Index (Place) : Kollam, Gst : 18% Printed On 2026-03-17 13:56:12.13 20 Thickness With Zinc Coating 120 Grams Per Sqm As Per Is: 277, In 240 Mpa Steel Grade, 5-7 Microns Epoxy Primer On Both Side Of The Sheet And Polyester Top Coat 15-18 Microns. Sheet Should Have Protective Guard Film Of 25 Microns Minimum To Avoid Scratches During Transportation And Should Be Supplied In Single Length Upto 12 Metre Or As Desired By Engineer-In-Charge. The Sheet Shall Be Fixed Using Self Drilling/Self Tapping Screws Of Size (5.5X55Mm) With Epdm Seal, Complete Upto Any Pitch In Horizontal/ Vertical Or Curved Surfaces, Excluding The Cost Of Purlins, Rafters And Trusses And Including Cutting To Size And Shape Wherever Required. 157 12.51.1 Providing And Fixing Precoated Galvanised Steel Sheet Roofing Accessories 0.50 Mm (+0.05 %) Total Coated Thickness, Zinc Coating 120 Grams Per Sqm As Per Is: 277, In 240 Mpa Steel Grade, 5-7 Microns Epoxy Primer On Both Side Of The Sheet And Polyester Top Coat 15-18 Microns Using Self Drilling/ Self Tapping Screwscomplete :Ridges Plain (500-600 Mm)
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
22.
Housing Urban and Rular Development #11306856 AOC
Tender For M.O.W. Work (Additional Room) In Bunglow No. Eg-9/3 And Ek-9/3 Under Section No.1 Survey Sub Dn. Bhopal- 1 M.O.W. Work (Additional Room) in Bunglow No. EG-9/3 and EK-9/3 Under Section No.1 Survey Sub Dn. Bhopal 1st Call P.A.C. 29.64 Lakh,as per Building SOR wef 01-01-2024 Schedule Attached Complition period 90 Days Please Enable Macros to View BoQ information SCHEDULE OF ITEMS Name of work : M.O.W. Work (Additional Room) in Bunglow No. EG-9/3 and EK-9/3 Under Section No.1 Survey Sub Dn. Bhopal Probable Amount of contract : Rs. 29.64 Lacs. (Rs. in Figures) : Time Alloved : 6 months i/c rainy season S.No SOR Item Particulers of Item Unit Rate Remarks 2 2.4 2.4.1 beyond 30 cm girth up to and including 60 cm girth each 350.0 2.4.2 beyond 60 cm girth up to and including 120 cm girth each 1150.0 2.4.3 beyond 120 cm girth up to and including 240 cm girth each 3500.0 2.4.4 above 240 cm girth each 6300.0 3 2.7 2.7.1 Ordinary rock cum 287.0 2.7.2 Hard rock (requiring blasting) cum 519.0 2.7.3 Hard rock (blasting prohibited) cum 828.0 4 2.25 2.25.1 All kinds of soil. cum 30.0 2.25.2 Ordinary or hard rock. cum 53.0 2.26 Supplying and filling in plinth with crusher stone dust / coarse sand under floors including, watering, ramming and compacting in layers not exceeding 20cm in depth and dressing complete cum 672.0 Note: - Maximum thickness of this layer shall be 20 cm. 5 2.27 2.27.1 With hard muram having CBR >12 % at under floors including watering, ramming and compacting (minimum compaction 95% of MDD) in layers not exceeding 20cm in thickness and dressing complete. (Note:- maximum thickness of this layer to be provided shall be 30cm) cum 393.0 2.27.2 Supplying and filing in plinth with soil (other then BC soil ) having MDD not less than 1.85 t/m3 under floors including watering, ramming and compacting (minimum compaction 95% of MDD) in layers not exceeding 15cm cum 331.0 6 2.28 2.28.1 All kinds of soil. each 42.0 2.28.2 Ordinary rock each 68.0 2.28.3 Hard rock (requiring blasting) each 138.0 2.28.4 Hard rock (blasting prohibited) each 151.0 7 2.3 2.30.1 Along external wall where the apron is not provided using chemical emulsion@ 7.5 liters / sqm of the vertical surfaceof the substructure to a depth of 300mm including excavation channel along the wall and rodding etc. complete, with Chlorpyriphos/ Lindane E.C. 20% with 1% concentration. metre 36.0 2.30.2 Along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc. With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration. metre 42.0 2.30.3 Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diametre holes and plugging with cement mortar 1 :2 (1 cement : 2 sand) to match the existing floor, With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration. sqm 199.0 2.30.4 Treatment of existing masonry using chemical emulsion @ one litre per hole at 300 mm interval including drilling 10mm dia and 200mm deep holes at 45 degree and plugging them with cement mortar 1:2 (1 cement : 2 sand) to the full depth of the hole, with Chlorpyriphos/ Lindane E.C. 20% with 1% concentration. metre 50.0 2.30.5 Treatment at points of contact of wood work by chemical emulsion Chlorpyriphos/ Lindane (in oil or kerosene based solution) @ 0.5 litresper hole by drilling 6 mm dia holes at downward angle of 45 degree at 150mm centre to centre and sealing the same. metre 201.0 8 2.41 2.42.1 Supplying and filing in plinth with soil (other then BC soil ) having MDD not less than 1.85 t/m3 under floors including watering, ramming and compacting (minimum compaction 95% of MDD) in layers not exceeding 15cm depth and dressing complete. cum 331.0 9 4.1 4.1.1 With 20mm nominal size graded stone aggregate. 4.1.1.1 M-25 – Grade concrete cum 6338.0 4.1.1.2 M-20 – Grade concrete cum 4933.0 4.1.1.3 M-15 – Grade concrete cum 4471.0 4.1.1.4 M-10Nominal (Mix-1 Cement : 3 sand : 6 graded stone aggregate ) cum 3890.0 4.1.2 With 40mm nominal size graded stone aggregate. 4.1.2.1 M-15 - Grade concrete cum 4403.0 4.1.2.2 M-10 Nominal (Mix -1 Cement : 3 sand : 6 graded stone aggregate) cum 3808.0 4.1.2.3 M-7.5 Nominal Mix -1 Cement : 4 sand : 8 graded stone aggregate cum 3474.0 4.1.3 With fly ash. Note: No fly ash is to be added to Portland Pozzolona cement in any case which itself contains fly ash. 10 4.2 string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets etc. upto floor two level, excluding the cost of centering, shuttering and finishing : 4.2.1 With 20mm nominal size graded stone aggregate 4.2.1.1 M-25 – Grade concrete Cum 6582.0 4.2.1.2 M 20 – Grade concrete Cum 5177.0 4.2.1.3 M 15 – Grade concrete Cum 4714.0 4.2.1.4 M-10 Nominal Mix -1 Cement : 3 sand : 6 graded stone aggregate Cum 4134.0 4.2.2 With 40mm nominal size graded stone aggregate 4.2.2.1 M-15 - Grade concrete cum 4647.0 4.2.2.2 M-10 Nominal Mix -1 Cement : 3 sand : 6 graded stone aggregate cum 4052.0 11 4.3 4.3.1 Upto plinth: Foundations, footings, bases for columns, plinth beams, curtain walls, columns below plinth. Sqm 169.0 4.3.2 above plinth: Retaining walls, return walls, walls (any thickness) including attached pilasters, buttresses, and string courses fillets etc. sqm 267.0 4.3.3 Above plinth: Columns, pillars, posts and struts. Sqm 356.0 12 4.6 4.6.1 M-25 (With 20mm nominal size graded stone aggregate) cum 5095.0 4.6.2 M-20 (With 20mm nominal size graded stone aggregate) cum 5558.0 4.6.3 M-15 (With 20mm nominal size graded stone aggregate) cum 5095.0 4.6.4 M-10 (With 20mm nominal size graded stone aggregate) Nominal Mix -1 Cement: 3 sand: 6 graded stone aggregate. cum 4515.0 4.1 Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement: 2 sand: 4 graded stone aggregate 12.5mm nominal size). Sqm 200.0 13 5.1 5.1.1 M-20 Grade Concrete cum 6153.0 5.1.2 M-15 Grade Concrete cum 5397.0 14 5.2 5.2.1 M-20 Grade Concrete cum 6231.0 15 5.3 5.3.1 M-20 Grade Concrete cum 6541.0 16 5.4 5.4.1 M-20 Grade Concrete cum 5542.0 17 5.5 5.5.1 M-20 Grade Concrete cum 6906.0 18 5.6.1 5.6.1 M-20 Grade Concrete cum 6337.0 19 5.7.1 5.7.1 M-20 Grade Concrete cum 5448.0 20 5.9.1 5.9.1 Foundations, footings, bases of columns, etc. for concrete upto plinth level sqm 190.6 5.9.2 Walls (any thickness) in cluding attached pilasters butter esses, plinth beams and string courses etc. 5.9.2.1 Uptoplinthlevel. sqm 219.0 5.9.2.2 Above plinth upto 3.6 m height from plinth level sqm 330.0 5.9.2.3 Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc. including cost of de-shuttering and decentering at all levels, over a height of 3.6 m, for every additional height of 1 metre or part thereof. sqm 40.0 5.9.3 Suspended floors, roofs, landings, balconies and access platform. sqm 439.6 5.9.4 Shelves(Cast in situ) sqm 290.0 5.9.5 Lintels, beams, girders, bressumers and cantilevers sqm 356.0 5.9.6 Columns, P i l l a r s , Piers, Abutments, sqm 471.2 Posts and Struts. 5.9.7 Stairs, (excluding landings) except spiral- Staircases. sqm 435.7 5.9.8 Spiral staircases (including landing). sqm 450.0 5.9.9 Arches, domes,vaults upto 6m span sqm 1141.6 5.9.10 Extra for arches, domes, vaults exceeding 6 m span sqm 451.3 5.9.11 Chimneys and shafts sqm 294.0 5.9.12 Coffer/waffle slab of any size or shape as shown in the drawing. sqm 1481.0 5.9.15 Extra for shuttering in circular work or any other geometrical shape (20% of respective centering and shuttering items). sqm 0.2 5.9.16 Small lintels not exceeding 1.5m clear span, mouldingas incornices, window, sills, courses, bands, copings, bed plates, anchor blocks and the like. sqm 191.0 5.9.17 Cornices and mouldings sqm 565.0 5.9.18 Small surfaces such as cantilever ends, brackets and ends of steps, caps and bases to pilasters and columns and the like. sqm 529.6 5.9.19 Weather shade, Chajjas, corbels etc., including Edges. sqm 534.2 5.9.20 Suspended floors, roofs, landings, balconies and Access platform. With water proof ply 12 mm thick. (item to be executed with prior permission of C.E./S.E. in case of B & R works . sqm 575.35 5.9.21 Lintels, beams, columns, girders, bressumers and cantilevers with waterproof ply 12 mm thick (item to be executed with prior permission of C.E./S.E. in case of B & R works . sqm 521.2 21 5.1 5.10.1 Suspended floors, roofs, landing, beams and balconies (Plan area to be measured). sqm 212.0 22 5.12 5.12.1 50 mm thick sqm 790.0 5.12.2 40 mm thick sqm 689.0 5.12.3 25 mm thick sqm 598.0 23 5.16 5.16.1 Mild steel and Medium Tensile steel bars. kg 78 .00 5.16.2 Hard drawn steel wire kg 75.0 5.16.3 Cold twisted bars (CTD) kg 81.0 5.16.4 Hot rolled deformed bars kg 81.0 5.16.5 Hard drawn steel wire fabric kg 76.0 5.16.6 Thermo-Mechanically Treated bars.FE 500 D or more conforming to IS 1786 kg 80.0 5.16.7 Thermo-Mechanically Treated bars. FE 500 conforming .to IS 1786 kg 77.0 5.16.8 Corrosion resistance Steel bar Grade Fe-500 D & above , use with prior permission of C.E. Kg 98.0 24 5.22 5. 22.1 12 mm thick sqm 402.0 5. 22.2 25 mm thick sqm 574.0 5. 22.3 50 mm thick sqm 674.0 5.23 Providing and fixing sheet covering over expansion joints with iron screws as per design. 5. 23.1 Non-asbestos fibre cement board 6 mm thick as per IS: 14862. 5. 23.1.1 150mm wide. RM 102.0 5. 23.1.2 200mm wide. RM 137.0 5. 23.1.3 250mm wide. RM 153.0 5. 23.2 Aluminium fluted strips 3.15mm thick. 5. 23.2.1 150 mm wide. RM 483.0 5. 23.2.2 200 mm wide. RM 646.0 5. 23.2.3 250 mm wide. RM 725.0 5. 23.3 Stainless steel Grade 304 plate-1.0 mm thick 5. 23.3.1 150 mm wide. RM 367.0 5. 23.3.2 200 mm wide. RM 443.0 5. 23.3.3 250 mm wide. RM 555.0 25 5.24 5.24.1 Preparation of grooves RM 18.5 5.24.2 Preparation of Drip course RM 30.0 26 5.32 5.32.1 Non pigmented wet curing compound sqm 93.0 5.32.2 Pigmented wet curing compound. sqm 100.0 27 6.1 6.1.1 Cement mortar 1:4 (1 cement : 4 sand) cum 5818.0 6.1.2 Cement mortar 1:6 (1 cement : 6 sand) cum 5626.0 28 6.2 6.2.1 Cement mortar 1:4 (1 cement : 4 sand) cum 6012.0 6.2.2 Cement mortar 1:6 (1 cement : 6 sand) cum 5821.0 6.3 Brick work with well burnt chimney bricks in bulls pattern trench kiln manufactured by ghol process, crushing strength not lessthan 40kg /cm2 and water absorptionnot more than 15% in foundation and plinth i/c curing etc. complete. 6.3.1 Cement mortar 1:4 (1 cement : 4 sand) cum 5252.0 6.3.2 Cement Mortar 1:6 (1 cement:6 sand). cum 5061.0 29 6.4 6.4.1 Cement mortar 1:4 (1 cement : 4 sand) cum 5446.0 6.4.2 Cement Mortar 1:6 (1 cement:6 sand). cum 5255.0 30 6.5 6.5.1 Cement mortar 1:4 (1 cement : 4 sand) cum 4347.0 6.5.2 Cement Mortar 1:6 (1 cement: 6 sand). cum 4155.0 31 6.6 6.6.1 Cement mortar 1:4 (1 cement : 4 sand) cum 4541.0 6.6.2 Cement Mortar 1:6 (1 cement : 6 sand) cum 4350.0 32 6.7 6.7.1 Having 100 kg / cm2 average compressive strength. 6.7.1.1 Cement mortar 1:4 (1 cement : 4 sand) cum 5384.0 6.7.1.2 Cement mortar 1:6 (1 cement : 6 sand) cum 5162.0 6.7.2 Having 75 kg / cm2 average compressive strength. 6.7.2.1 Cement mortar 1:4 (1 cement : 4 sand) cum 5271.0 6.7.2.2 Cement mortar 1:6 (1 cement : 6 sand) cum 5049.0 6.7.3 Having 50 kg / cm2 average compressive strength. 6.7.3.1 Cement mortar 1:4 (1 cement : 4 sand) cum 5158.0 6.7.3.2 Cement mortar 1:6 (1 cement : 6 sand) cum 4936.0 33 6.8 6.8.1 Cement mortar 1:4 (1 cement : 4 sand) cum 5287.0 6.8.2 Cement mortar 1:6 (1 cement : 6 sand) cum 5095.0 34 6.9 Cement Mortar 1:4 ( 1 cement : 4 sand) 35 6.12 6.12.1 Cement mortar 1:3 (1 cement : 3 sand) sqm 697.0 6.12.2 Cement mortar 1:4 (1 cement : 4 sand) sqm 673.0 36 6.13 6.13.1 Cement mortar 1:3 (1 cement : 3 sand) sqm 639.0 6.13.2 Cement mortar 1:4 (1 cement : 4 sand) sqm 615.0 37 6.14 6.14.1 Cement mortar 1:3 (1 cement : 3 sand) sqm 546.0 6.14.2 Cement mortar 1:4 (1 cement : 4 sand) sqm 522.0 38 6.15 6.15.1 Having 100 kg/cm2 average compressive strength. 6.15.1.1 Cement mortar 1 : 3 (1 cement : 3 sand) sqm 570.0 6.15.1.2 Cement mortar 1 : 4 (1 cement : 4 sand) sqm 551.0 6.15.2 Having 75 kg/cm2 average compressive strength. 6.15.2.1 Cement mortar 1 : 3 (1 cement : 3 sand) sqm 524.0 6.15.2.2 Cement mortar 1 : 4 (1 cement : 4 sand) sqm 505.0 6.15.3 Having 50 kg/cm2 average compressive strength. 6.15.3.1 Cement mortar 1 : 3 (1 cement : 3 sand) sqm 479.0 6.15.3.2 Cement mortar 1 : 4 (1 cement : 4 sand) sqm 459.0 39 6.37 6.37.1 Having100 kg / cm2 average compressive strength. 6.37.1.1 Cement mortar 1:4 (1 cement : 4 sand) cum 5115.0 6.37.1.2 Cement mortar 1:6 (1 cement : 6 sand) cum 4904.0 6.37.2 Having75 kg / cm2 average compressive strength. 6.37.2.1 Cement mortar 1:4 (1 cement : 4sand) cum 5007.0 6.37.2.2 Cement mortar 1:6 (1 cement : 6sand) cum 4797.0 6.37.3 Having50 kg / cm2 averagecompressive strength. 6.37.3.1 Cement mortar 1:4 (1 cement : 4sand) cum 4900.0 6.37.3.2 Cement mortar 1:6 (1 cement : 6sand) cum 4689.0 40 9.3 9.3.1 Sal wood cum 76229.0 9.3.2 Kiln seasoned and chemically treated hardwood Haldu, Kail, Bija wood. cum 77538.0 9.3.3 Factory made Kiln seasoned, chemically treated, finger jointed at spacing not closer than 50 cm, 2nd class hard wood. cum 64833.0 41 9.4 9.4.1 Second class teak wood cum 9062.0 9.4.2 Sal wood cum 7131.0 9.4.3 Kiln seasoned and chemically treated Haldu, Kail, Bija wood. cum 7275.0 9.4.4 Factory made Kiln seasoned, chemically treated, finger jointed at spacing not closer than 50 cm, 2nd class hard wood. cum 6030.0 9.5.4.1 35 mm thick sqm 1089.0 9.5.4.2 30 mm thick sqm 969.0 42 9.6 9.6.1 Second class teak wood sqm 2215.0 9.6.2 Kiln seasoned and chemically treated Haldu, Kail, Bija wood sqm 1763.0 9.6.3 15mm thick Factory made Kiln seasoned, chemically treated and finger jointed at spacing not closer than 50cm, 2nd class hard wood. sqm 971.0 9.6.4 Ply wood 5 ply, 9 mm thick : 9.6.4.1 Decorative plywood both side decorative veneer (Type - I) conforming to IS 1328 BWR type. sqm 1439.0 9.6.4.2 Decorative plywood one side decorative veneer and commercial veneer on other face (Type 1) conforming to IS 1328 BWR Type sqm 1369.0 9.6.5 Ply wood 7 ply, 9 mm thick : 9.6.5.1 Decorative plywood both side decorative veneer (Type- I) conforming to IS 1328 BWR type. sqm 1861.0 9.6.5.2 Decorative plywood one side decorative veneer and commercial veneer on other face (Type-1) conforming to IS 1328 BWR Type sqm 1650.0 9.6.6 Particle Board 12 mm thick 9.6.6.1 Plain particle board flat pressed, 3 layer or graded wood particle board medium density Grade I, IS: 3087 marked. sqm 791.0 9.6.6.2 Veneered flat pressed three layer or graded wood particle board with commercial veneering on both sides conforming to IS: 3097, grade I. sqm 1087.0 9.6.6.3 Pre-laminated particle board with decorative lamination on one side and balancing lamination on other side, Grade I, Type II IS: 12823 marked. sqm 1333.0 9.6.6.4 Pre-laminated particle board with decorative lamination on both sides, Grade I, Type II, IS: 12823 marked. sqm 1390.0 9.6.6.5 Coir Veneer Board (conforming to IS 14842) 12 mm thick sqm 1298.0 9.6.7 Float glass panes 9.6.7.1 4 mm thick glass pane (weight not less than 10 kg/sqm) sqm 973.0 9.6.7.2 5 mm thick glass pane (weight not less than 12.5 kg/sqm) sqm 1046.0 9.6.8 Fly proof stainless steel grade 304 wire gauge with 0.5 mm dia. Wire and 1.4 mm wide aperture with matching wood beading sqm 1532.0 9.6.8.1 4mm to 5mm thick integral PVC form sheet with Celluka finish surface on both side with density not less than 600 kg/cum sqm 580.0 9.6.8.2 4mm to 5mm thick laminated PVC form sheet with density not less than 600 kg/cum, laminated on both sides by 0.12 mm thick laminated sheet with density not less than 1400 kg/cum sqm 754.0 43 9.14 9.14.1 Stainless steel butt hinges with stainless steel screws for 2nd class teak wood and other class of wood shutters. Sqm 170.0 9.14.2 ISI marked M.S. pressed butt hinges bright finished of required size For 2nd class teak wood and other class of wood shutters. Sqm 53.0 44 9.15 9.15.1 Panelled or panelled and glazed shutters : 9.15.1.1 Using ISI marked anodised aluminium butt hinges with necessary screws. Sqm 2736.0 9.15.1.2 Using ISI marked nickel plated bright finished M.S. piano hinges with necessary screws. Sqm 2753.0 9.15.2 Glazed shutters : 9.15.2.1 Second class teak wood including ISI marked anodised aluminium butt hinges with necessary screws. Sqm 2815.0 9.15.2.2 2nd class teak wood including ISI marked nickel plated bright finished M.S. piano hinges with necessary screws. Sqm 2759.0 45 9.16 9.16.1 12 mm thick Sqm 555.0 9.16.2 18 mm thick Sqm 654.0 46 9.17 9.17.1 18 mm thick Sqm 1270.0 9.17.2 25 mm thick Sqm 1383.0 47 9.18 9.18.1 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws. Sqm 2823.0 9.18.2 30 mm thick including ISI marked Stainless Steel butt hinges with necessary screws. Sqm 2648.0 9.18.3 25 mm thick (for cupboard) including ISI marked nickel plated bright finished M.S. Piano hinges IS: 3818 marked with necessary screws. Sqm 2465.0 48 9.19 9.19.1 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws. Sqm 1870.0 9.19.2 30 mm thick including ISI marked Stainless Steel butt hinges with necessary screws. Sqm 1696.0 9.19.3 25mm thick (for cupboard) including ISI marked nickel plated bright finished M.S. piano hinges with necessary screws. Sqm 1623.0 49 9.2 9.21 Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). Sqm 401.0 9.22 Extra for providing vision panel not exceeding 0.1 sqm in all type of flush doors (cost of glass excluded) (overall area of door shutter to be measured) : 9.22.1 Rectangular or square. Sqm 157.0 9.22.2 Circular. Sqm 244.0 50 9.25 9.25.1 35 mm thick shutters with ISI marked M.S. pressed butt hinges bright finished of required size. 9.25.1.1 Second class teak wood. Sqm 3174.0 9.25.1.2 Kiln seasoned and chemically treated Haldu, Kail, Bija wood. Sqm 2599.0 9.25.1.3 Kiln seasoned selected class of sheesham wood. Sqm 2452.0 9.25.2 35 mm thick shutters with ISI marked stainless steel butt hinges of required size. 9.25.2.1 Second class teak wood. Sqm 3291.0 9.25.2.2 Kiln seasoned and chemically treated Haldu, Kail, Bija wood. Sqm 2716.0 9.25.2.3 Kiln seasoned selected class of sheesham wood. Sqm 2569.0 9.25.3 30 mm thick shutters with ISI marked M.S. pressed butt hinges bright finished of required size. 9.25.3.1 Second class teak wood. Sqm 2797.0 9.25.3.2 Kiln seasoned and chemically treated Haldu, Kail, Bija wood. Sqm 2306.0 9.25.3.3 Kiln seasoned selected class of sheesham wood. Sqm 2179.0 9.25.4 30 mm thick shutters with ISI marked stainless steel butt hinges of required size. 9.25.4.1 Second class teak wood. Sqm 2914.0 9.25.4.2 Kiln seasoned and chemically treated Haldu, Kail, Bija wood. Sqm 2423.0 9.25.4.3 Kiln seasoned selected class of sheesham wood. Sqm 2296.0 9.26.2 30 mm thick shutters Sqm 2102.0 51 9.57 9.57.1 300x16 mm Each 170.0 9.57.2 250x16 mm Each 157.0 52 9.58 9.58.1 250x10 mm Each 68.0 9.58.2 200x10 mm Each 60.0 9.58.3 150x10 mm Each 42.0 9.58.4 100x10 mm Each 35.0 53 9.6 9.60.1 300x20x6 mm Each 72.0 9.60.2 250x20x6 mm Each 67.0 54 9.61 9.61.1 125 mm Each 27.0 9.61.2 100 mm Each 25.0 9.61.3 75 mm Each 24.0 55 9.62 9.62.1 150 mm Each 23.0 9.62.2 115 mm Each 20.0 9.62.3 90 mm Each 17.0 56 9.63 9.63.1 300 mm weighing not less than 200 gms. Each 40.0 9.63.2 250 mm weighing not less than 150 gms. Each 34.0 9.63.3 200 mm weighing not less than 120 gms. Each 28.0 57 9.65 9.65.1 300x16 mm Each 389.0 9.65.2 250x16 mm Each 326.0 9.65.3 400x16mm Each 601.0 58 9.66 9.66.1 250x10 mm Each 148.0 9.66.2 200x10 mm Each 93.0 9.66.3 150x10 mm Each 71.0 9.66.4 100x10 mm Each 50.0 59 9.68 9.68.1 300x20x6 mm Each 211.0 9.68.2 250x20x6 mm Each 173.0 9.69 Providing and fixing ISI marked stainless steel handles with necessary screws etc. complete : Each 9.69.1 125 mm Each 60.0 9.69.2 100 mm Each 54.0 9.69.3 75 mm Each 48.0 60 9.7 9.70.1 150 mm each 37.0 9.70.2 115 mm each 33.0 9.70.3 90 mm each 26.0 61 9.73 9.73.1 125x64x1.90 mm each 67.0 9.73.2 100X58X1.90 mm each 59.0 9.73.3 75x47x1.80 mm each 39.0 9.73.4 50x37x1.50 mm each 25.0 62 9.74 9.74.1 125x64x2.50 mm each 76.0 9.74.2 100x60x2.50 mm each 60.0 9.74.3 75x50x2.50 mm each 46.0 63 9.76 9.77 Providing and fixing bright finished brass butt hinges with necessary screws etc. complete : 9.77.1 125x85x5.5 mm (heavy type) each 456.0 9.77.2 125x70x4 mm (ordinary type) each 148.0 9.77.3 100x85x5.5 mm (heavy type) each 387.0 9.77.4 100x70x4 mm (ordinary type) each 117.0 9.77.5 75x65x4 mm (heavy type) each 145.0 9.77.6 75x40x2.5 mm (ordinary type) each 74.0 9.77.7 50x40x2.5 mm (ordinary type) each 32.0 64 9.78 9.78.1 150x125x27x5 mm each 385.0 9.78.2 125x125x27x5 mm each 345.0 9.78.3 100x125x27x5 mm each 304.0 9.78.4 75x100x20x3.2 mm each 239.0 65 9.79 9.79.1 400x10 mm each 400.0 9.79.2 250x10 mm each 329.0 9.79.3 200x10 mm each 261.0 9.79.4 150x10 mm each 221.0 9.79.5 100x10 mm each 142.0 66 9.8 9.80.1 300x16x5 mm each 237.0 9.80.2 250x16x5 mm each 225.0 67 9.81 9.81.1 125 mm each 205.0 9.81.2 100 mm each 181.0 9.81.3 75 mm each 141.0 68 9.82 9.82.1 300x16mm each 407.0 9.82.2 250x16mm each 374.0 69 9.87 9.87.1 40 mm each 144.0 9.87.2 50 mm each 150.0 9.87.3 65 mm each 162.0 9.87.4 75 mm each 185.0 70 9.99 9.99.1 Size 40 mm each 144.0 9.99.2 Size 50 mm each 156.0 9.99.3 Size 65 mm each 167.0 9.99.4 Size 75 mm each 196.0 71 9.101 9.101.1 300x16mm each 268.0 9.101.2 250x16mm each 245.0 72 9.102 9.102.1 400X10mm each 260.0 9.102.2 300x10mm each 198.0 9.102.3 250x10mm each 164.0 9.102.4 200x10 mm each 113.0 9.102.5 150x10 mm each 91.0 9.102.6 100x10 mm each 73.0 73 9.103 9.103.1 300x16x5mm each 255.0 9.103.2 250x16x5mm each 243.0 74 9.108 9.108.1 125x75x4 mm each 115.0 9.108.2 125x63x4 mm each 108.0 9.108.3 100x75x4 mm each 95.0 9.108.4 100x63x4 mm each 93.0 9.108.5 100x63x3.2 mm each 90.0 9.108.6 75x63x4 mm each 77.0 9.108.7 75x63x3.2 mm each 75.0 9.108.8 75x45x3.2 mm each 67.0 75 9.109 9.109.1 300x16 mm each 241.0 9.109.2 250x16 mm each 195.0 76 9.11 9.110.1 400X10mm each 123.0 9.110.2 300x10 mm each 114.0 9.110.3 250x10 mm each 102.0 9.110.4 200x10 mm each 82.0 9.110.5 150x10 mm each 69.0 9.110.6 100x10 mm each 55.0 77 9.111 78 9.113 9.113.1 125 mm each 75.0 9.113.2 100 mm each 55.0 9.113.3 75 mm each 46.0 79 9.114 9.114.1 Single rubber stopper each 35.0 9.114.2 Twin rubber stopper each 86.0 80 9.116 81 9.117 82 9.126 83 9.127 84 9.128 85 9.129 9.129.1 Triple strip vertical type. each 28.0 9.129.2 Double strip (horizontal type). each 23.0 9.131 Providing and fixing powder coated telescopic drawer channels with necessary screws etc. complete as per directions of Engineer-in-charge. 9.131.1 300mm long each set 209.0 9.131.2 450mm long each set 256.0 9.131.3 500mm long each set 302.0 86 9.132 87 9.133 9.133.1 Marine plywood conforming to IS: 710 sqm 1591.0 9.133.2 Fire retardant plywood conforming to IS: 5509. sqm 1660.0 88 9.134.1 9.134.1 1.5 mm thick. sqm 851.0 89 9.134.2 90 9.138 9.138.1 12 mm thick. sqm 919.0 9.138.2 18 mm thick. sqm 1161.0 9.138.3 25 mm thick. sqm 1230.0 91 9.139 92 9.14 9.140.1 18 mm thick sqm 1493.0 9.140.2 25 mm thick sqm 2017.0 93 9.145 9.145.1 Board 12 mm thick sqm 811.0 9.145.2 Board 18 mm thick sqm 943.0 9.146 Providing and fixing Pre-laminated medium density fibre board IS: 14587:1998 marked, with one side decorative lamination other side balancing lamination Grade-I(exterior grade) in shelves with screws and fittings wherever required, edges to be sealed with PVC edge bending tape 2.00 mm thick of approved brand (fittings to be paid separately). 9.146.1 18 mm thick sqm 1055.0 9.146.2 25 mm thick sqm 1420.0 94 9.147 95 9.148 96 9.15 9.150.1 12 mm thick commercial ply conforming to IS: 1328 BWR type. Sqm 1210.0 9.150.2 18 mm thick commercial ply conforming to IS: 1328 BWR type. Sqm 1320.0 97 9.158 9.158.1 Extruded section Profile size 48x40 mm. metre 203.0 9.158.2 Extruded section Profile size 42x50 mm. metre 208.0 98 9.165 99 9.166 9.166.1 Plain PVC door shutters. sqm 2026.0 9.166.2 Pre laminated PVC door shutters. sqm 2490.0 100 9.167 101 9.168 as panel. The styles andrails will be mitred cut and joint with the help of PVC solvent cement and self driven self tapping screws. Single piece extruded solid PVC lock rail of size 100 mm x 30 mm with wall thickness 5 mmand 15 mm integrally extruded in the middle of the lock rail and fixed with styles with the help of PVC solvent cement and self driven self tapping screws of size 100 mmx8 mm complete as per manufacturers specifications and direction of Engineer-in-charge: 9.168.1 Non decorative finish. sqm 2026.0 9.168.2 Decorative finish (both side wood grained finish). sqm 2432.0 102 9.169 9.169.1 Single rebate (75 mm X 50 mm) RM 459.0 9.169.2 Single rebate (100 mm X50 mm) RM 720.0 9.169.3 Single or double rebate (125 mm X 65 mm) RM 923.0 103 9.17 9.170.1 24 mm thick WPC (Wood polymer composite) solid plain flush door shutter sqm 2250.0 9.170.2 28 mm thick WPC (Wood polymer composite) solid plain flush door shutter sqm 3250.0 9.170.3 30 mm thick WPC (Wood polymer composite) solid plain flush door shutter sqm 3693.0 9.170.4 35 mm thick WPC (Wood polymer composite) solid plain flush door shutter sqm 4135.0 104 9.186 105 9.187 9.187.1 Casement Window (Outward/Inward opening) with hinge System. 9.187.1.1 Frame (50 mm x 50mm) metre 422.0 9.187.1.2 Sash (Style and Rail) (62 mm x 34 mm) metre 403.0 9.187.1.3 Mullion (intermediate Section) (66mm x 50 mm) metre 434.0 9.187.1.4 ‘T Profile (one vertical length in between two shutters) (24mm x 34.5mm) metre 99.0 9.187.1.5 Glazing bead (12mm x 18mm) metre 130.0 9.187.2 Casement Window (With friction hinge and outward opening) 9.187.2.1 Casement Frame (67mm x 62mm) metre 495.0 9.187.2.2 Casement Window Sash/Mullion (67mm x75mm) (style, rail and intermediate section) metre 519.0 9.187.2.3 Casement Glazing bead (35mm x 18 mm) metre 178.0 9.187.3 Sliding Window (Two Track, 2/4 Shutters) 9.187.3.1 Two Track Sliding Frame (67mm x 52mm) metre 9.187.3.2 Sliding window Sash (60mm x 44mm) metre 529.0 9.187.3.3 Sliding Interlock for Window (one vertical length in each shutter)(45.5 mm x 28 mm) metre 139.0 9.187.3.4 Sliding Glazing bead (35 mm x 18 mm) metre 178.0 9.187.4 Sliding Door (Two Track, 2/4 Shutters) 9.187.4.1 Two Track Sliding Frame (67mm x 52mm) metre 539.0 9.187.4.2 Sliding Door Sash (80mm x 44mm) metre 653.0 9.187.4.3 Sliding Interlock for Door (one vertical length in each shutter) (45.5 mm x 28 mm) metre 139.0 9.187.4.4 Sliding Glazing bead (35 mm x 18 mm) metre 178.0 106 9.188 9.188.1 200 x 19 x 1.9 mm each 321.0 9.188.2 250 x 19 x 1.9 mm each 369.0 9.188.3 300 x 19 x 1.9 mm each 462.0 9.188.4 350 x 19 x 1.9 mm each 526.0 9.188.5 400 x 19 x 1.9 mm each 636.0 107 9.189 108 9.191 109 9.192 110 9.193 111 9.194 9.194.1 Casement window single panel with S.S. friction hinges (300 x 19 x 1.9 mm), made of (small series) frame 47 x 50 mm & sash 47 x 68 mm both having wall thickness of 1.9 ± 0.2 mm and single glass pane glazing bead of appropriate dimension. (Area of window upto 0.75 sqm.) sqm 6798.0 9.194.2 Casement window double panels with S.S. friction hinges (300 x 19 x 1.9 mm) made of (small series) frame 47 x 50 mm, sash 47 x 68 mm & mullion 47 x 68 mm all having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension. (Area of window above 0.75 sqm upto 1.50 sqm). sqm 6221.0 9.194.3 Casement window double panels with top fixed with S.S. friction hinges (350 x 19 x 1.9 mm) made of (small series) frame 47 x 50 mm, sash 47 x 68 mm & mullion 47 x 68 mm all having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension. (Area of window upto 2.50 sqm). sqm 4842.0 9.194.4 Casement window single panel with S.S. friction hinges (400 x 19 x 1.9 mm) made of (big series) frame 67 x 60 mm & sash67 x 80 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 0.75 sqm.) sqm 6681.0 9.194.5 Casement window duble panel with S.S. friction hinges (400 x 19 x 1.9 mm) made of (big series) frame 67 x 60 mm & sash 67 x 80 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 1.50 sqm.) sqm 6942.0 9.194.6 Casement cum fixed panel window having both and single casement panel, middle fixed panels and at top completely fixed ventilator with S.S. friction hinges (350 x 19 x 1.9 mm) made of (big series) frame 67 x 60 mm & sash 67 x 80 mm & mullion67 x 80 all having wall thickness of 2.3 ±0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 3.00 sqm. Upto 5.00 sqm.) sqm 5290.0 9.195 Providing and fixing factory made UPVC white colour fixed glazed windows/ ventilators comprising of UPVC multi- chambered frame and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to UPVC profile), UPVC extruded glazing beads of appropriate dimension, EPDM gasket, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame shall be mitred cut and fusion welded at all corners, mullion (ifrequired) shall be also fusion welded including drilling of holes for fixing hardwares and drainage of water etc. Afterfixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately). 9.195.1 Fixed window / ventilator made of (small series) frame 47 x 50 mm & mullion 47 x 68 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension. (Area upto 0.75 sqm.) sqm 4860.0 9.196 Providing and fixing made UPVC white colour casement/ casement cum fixed glazed door comprising of UPVC multi- chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made fromroll forming process of required length(shape & size according to UPVC profile),UPVC 9.196.1 Casement door with 3D hinges made of (big series) frame 67 x 64 mm & sash 67 x 110 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of door upto 2.00 sqm). sqm 7085.0 9.196.2 Casement door with top hung ventilator with 3D and S.S. friction hinges (400 x 19 x 1.9 mm) made of (big series) frame 67 x 64 mm, sash 67 x 110 mm & mullion 67 x 80 mm all having wall thickness of 2.3 ±.0.2 mm and single glazing bead /double glazing bead of appropriate dimension. (Area of door upto 2.50 sqm). sqm 7063.0 9.197 Providing and fixing factory made UPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of UPVC multi-chambered frame with in- built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to UPVC profile), appropriate dimension of UPVC extruded glazing beads and UPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profileof frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardwares and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately) 9.197.1 Two track two panels sliding window made of frame 52 x 44 mm &sash 32 x 60 mm both having wall thickness of 1.9 ± 0.2mm and single glazing bead of appropriate dimension. (Area of window upto 1.75 sqm) sqm 5060.0 9.197.2 Three track three panels sliding window with fly proof SS wire mesh (Two nos. glazed & one no. wire mesh panels) made of frame 92 x 44 mm & sash 32 x 60 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension (Area of window upto 1.75 sqm). sqm 6880.0 9.197.3 Two track two panels sliding window made of frame 67 x 50 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2mm and single glazing bead / double glazing bead of appropriate dimension (Area of window above 1.75 sqm upto 2.50 sqm). sqm 5134.0 9.197.4 Three track three panels sliding window with fly proof S.S wire mesh (Two nos. glazed & one no. wire mesh panels) made of frame 116 x 45 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead/double glazing bead of appropriate dimension. (Area ofwindow above 1.75 sqm). sqm 6371.0 9.197.5 Three track three panels sliding window made of frame 116 x 45 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 1.75 sqm) sqm 5913.0 112 9.198 9.198.1 Two track two panels sliding window made of frame 67 x 50 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 2.50 sqm upto sqm 4332.0 4.00 sqm). 9.198.2 Two track four panels sliding window made of frame 67 x 50 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 4.00 sqm upto 8.00 sqm). sqm 3532.0 9.199 Providing and fixing factory made UPVC white colour sliding glazed door comprising of UPVC multi-chambered frame with in- built roller track and sashextruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to UPVC profile), appropriate dimension UPVC extruded glazing beads, UPVC extruded interlock and UPVC extruded Inline sash adaptor (if required), EPDM gasket, wool pile, zinc alloy (white powder coated) handle with key on one side of extreme panels along with zinc plated mild steel multi point locking having transmission gear with keeps, zinc alloy (white powder coated) cresent lock (if required), 9.199.1 Two track two panels sliding door made of frame 67 x 50 mm & sash 46 x 82 mm both having wall thickness of 2.3 ± 0.2 mmand single glazing bead / double glazing bead of appropriate dimension. (Area ofdoor above 2.00 sqm upto 10.00 sqm). sqm 3676.0 9.199.2 Two track four panels sliding door made of frame 67 x 50 mm & sash 46 x 82 mm both having wall thickness of 2.3 ± 0.2 mmand single glazing bead / double glazing bead of appropriate dimension. (Area ofdoor above 8.00 sqm upto10.00 sqm). sqm 3810.0 9.199.3 Three track three panels sliding door made of frame 116 x 45 mm & sash 46 x 82 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead/ double glazing bead of appropriate dimension. (Area of door above 5.00 sqm) sqm 4361.0 9.199.4 Three track three panels sliding door with fly proof S.S wire mesh (Two nos. glazed & one no. wire mesh panels) made of frame 116 x 45 mm & sash 46 x 82 mm both having wall thickness of 2.3 ± 0.2 mmand single glazing bead / double glazing bead of appropriate dimension. (Area ofdoor above 2.00 sqm upto 5.00 sqm) sqm 5617.0 9.2 Providing and fixing 30mm thick factory made solid panel prelaminated PVC internal door shutter consisting of frame made out of M.S. tubes of 19 gauge thickness and size of 40mm x 20mm for styles top, lock and bottom rails. M.S.frame shall have a coat of steel primers of approved make and manufacture.M.S. frame sqm 3908.0 113 9.201 9.201.1 24 to 25 mm thick plain solid PVC flush door shutter sqm 2250.0 9.201.2 28 to 30 mm thick plain solid PVC flush door shutter sqm 3229.0 114 9.202 9.202.1 1mm thick laminated sheet sqm 3693.0 9.202.2 0.12 mm thick laminated sheet sqm 3461.0 115 9.255 9.255.1 9 mm thick BWP grade commercial Sqm 841.0 plywood 9.255.2 12 mm thick BWP grade commercial Sqm 1064.0 plywood 9.255.3 18 mm thick BWP grade commercial Sqm 1169.0 plywood 9.255.4 25 mm thick BWP grade commercial Sqm 1366.0 plywood 116 9.256 9.256.1 25 mm outer dia & 300 mm long Each Set 984.0 9.256.2 32 mm outer dia & 450 mm long Each Set 1716.0 9.256.3 32 mm outer dia & 600 mm long Each Set 2041.0 117 9.257 9.196, 9.197, 9.198, 9.199) 118 9.258 9.258.1 Stainless steel (grade 304) wire gauze of 0.5 mm dia wire and 1.4 mm aperture on both sides. sqm 1040.0 119 10.7 10.7.1 Exceeding 10.00 sqm and upto 16.80 sqm in the area. sqm 747.0 10.7.2 Exceeding 16.80 sqm in area. sqm 782.0 120 10.11 10.11.1 Fixing with carbon steel galvanised dash fastener of required dia and size (to be paid for separately). kg 77.0 121 10.12 10.12.1 Profile B of 1.60mm thick single rebate of size 80mmx50mm 10.12.1.1 Fixing with adjustable lugs with split end tail to each jamb. meter 402.0 10.12.1.2 Fixing with carbon steel galvanised dash fastener of required dia and size (to be paid for separately). meter 394.0 10.12.2 Profile C of 1.60mm thick single rebate of size 100mmx50mm 10.12.2.1 Fixing with adjustable lugs with split end tail to each jamb. meter 431.0 10.12.2.2 Fixing with carbon steel galvanised dash fastener of required dia and size (to be paid for separately). meter 424.0 10.12.3 Profile E of 1.60mm thick double rebate of size 115mmx50mm 10.12.3.1 Fixing with adjustable lugs with split end tail to each jamb. meter 472.0 10.12.3.2 Fixing with carbon steel galvanised dash fastener of required dia and size (to be paid for separately). meter 464.0 10.12.4 Profile B of 1.25mm thick single rebate of size 80mmx50mm 10.12.4.1 Fixing with adjustable lugs with split end tail to each jamb. meter 356.0 10.12.4.2 Fixing with carbon steel galvanised dash fastener of required dia and size (to be paid for separately). meter 348.0 10.12.5 Profile C of 1.25mm thick single rebate of size 100mmx50mm 10.12.5.1 Fixing with adjustable lugs with split end tail to each jamb. meter 385.0 10.12.5.2 Fixing with carbon steel galvanised dash fastener of required dia and size (to be paid for separately). meter 377.0 10.12.6 Profile E of 1.25mm thick double rebate of size 115mmx50mm 10.12.6.1 Fixing with adjustable lugs with split end tail to each jamb. meter 414.0 10.12.6.2 Fixing with carbon steel galvanised dash fastener of required dia and size (to be paid for separately). meter 406.0 122 10.14 10.14.1 Hot finished welded type tubes kg 117.0 10.14.2 Hot finished seamless type tubes kg 123.0 10.14.3 Electric resistance or induction butt welded tubes. kg 142.0 10.15 Design, supply, fabrication, taransportion and erection of structural steel/mild steel built-up sections for steel building in column, rafter, truss, floor joist, wind bracings, tie beam, foundation bolts, fasteners etc. Including two coats ofEpoxy paint and one coat of primer. These structural steel/built-up sections shall be manufactured using advanced CNC Plasma/Oxy Acetylene cutter and H Beam Welding line. Welding shall be in full depth on both sides of the plate adopting relevant I.S Code. kg 132.0 123 10.17 124 10.18 125 10.19 126 10.21 127 10.22 10.22.1 In stringers, treads, landings etc. of stair cases including use of chequered plate wherever required, all complete. kg 101.0 10.22.2 In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works. kg 105.0 128 10.23 10.23.1 M.S. tube. kg 117.0 10.23.2 E.R.W. tubes. kg 132.0 129 10.25 130 10.26 10.26.1 Galvanised M.S. Wire gauze with 0.63mm dia wire and 1.4 mm aperture on both sides sqm 646.0 10.26.2 Stainless steel (grade 304) wire gauze of 0.5 mm dia wire and 1.4 mm aperture on both sides. sqm 1334.0 131 10.27 10.27.1 With 4.0 mm thick glass panes sqm 792.0 10.27.2 With 5.50 mm thick glass panes sqm 873.0 10.27.3 With 1mm thick mild steel sheet i/c 10x10x1.6mm box beading. sqm 916.0 10.27.4 With 2mm thick fibre reinforced polymer (FRP) sheet i/c 10x10x1.6mm boxbeading. sqm 611.0 10.27.5 With 1mm thick Galvanised steel sheet i/c 10x10x1.6mm box beading. sqm 936.0 10.27.6 With 4mm thick cement fibre board conforming to IS 14862:2000 of category type A grade i/c 10x10x1.6mm box beading. sqm 750.0 10.27.7 With 6mm thick cement fibre board conforming to IS 14862:2000 of category type A grade i/c 10x10x1.6mm box beading. sqm 800.0 10.27.8 With 8mm thick cement fibre board conforming to IS 14862:2000 of category type A grade i/c 10x10x1.6mm box beading. sqm 872.0 132 10.28 10.28.1 With 4.0 mm thick glass panes. sqm 259.0 10.28.2 With 5.5 mm thick glass panes. sqm 262.0 133 10.29 134 11.19 11.19.1 Makrana white second quality. sqm 3051.0 11.19.2 Raj Nagar plain. sqm 1381.0 11.19.3 Agaria White/Morgarh sqm 1882.0 11.19.4 Katni marble sqm 1555.0 11.19.5 Black Zebra. sqm 1315.0 11.19.6 Udaipur / Baroda green marble sqm 1649.0 11.19.7 Pink plain marble. sqm 1448.0 11.19.8 Jaisalmer Yellow sqm 1582.0 135 11.2 11.20.1 Makrana white second quality. sqm 3675.0 11.20.2 Raj Nagar plain. sqm 1932.0 11.20.3 Agaria White/Morgarh sqm 2455.0 11.20.4 Katni marble sqm 2113.0 11.20.5 Black Zebra. sqm 1863.0 11.20.6 Udaipur / Baroda green marble sqm 2211.0 11.20.7 Pink plain marble. sqm 2002.0 11.20.8 Jaisalmer Yellow sqm 2141.0 136 11.21 11.21.1 Makrana white second quality. sqm 3773.0 11.21.2 Raj Nagar plain. sqm 2737.0 11.21.3 Agaria White/Morgarh sqm 2553.0 11.21.4 Katni marble sqm 2219.0 11.21.5 Black Zebra. sqm 1961.0 11.21.6 Udaipur / Baroda green marble sqm 2309.0 11.21.7 Pink plain marble. sqm 2100.0 11.21.8 Jaisalmer Yellow sqm 2240.0 137 11.22 11.22.1 Raj Nagar plain/White Marble/Udaipur Green Marble /Zebra black sqm 1797.0 11.22.2 Granite fine grained dark crystal of other colours and various patterns sqm 2356.0 11.22.3 Granite coarse grained light black/ light red/white with crystal of other colours and various patterns Sqm 2113.0 11.22.4 Granite grey/pink/brown with various patterns Sqm 1808.0 11.22.5 Cuddpah stone sqm 1279.0 138 11.23 139 11.24 140 11.25 141 11.29 11.29.1 Area of slab over 0.50 sqm 11.29.1.1 Fine grained granite dark Black/dark Red/ White or equivalent with self design/ pattern/crystals of other colors of glitter sqm 2919.0 11.29.1.2 Coarse grained granite light Black/light Red/ off White or equivalent with self design/ pattern/crystals of other colors of glitter sqm 2675.0 11.29.1.3 Gray/Pink/Brown or equivalent with various patterns sqm 2370.0 11.29.2 Area of slab upto 0.50 sqm 11.29.2.1 Fine grained granite dark Black/dark Red/ White or equivalent with self design/ pattern/crystals of other colors of glitter sqm 2705.0 11.29.2.2 Coarse grained granite dark Black/dark Red/ White or equivalent with self design/ pattern/crystals of other colors of glitter sqm 2486.0 11.29.2.3 Gray/Pink/Brown or equivalent with various patterns sqm 2212.0 142 11.3 11.30.1 Area of slab over 0.50 sqm 11.30.1.1 Fine grained granite dark Black/dark Red/ White or equivalent with self design/ pattern/crystals of other colors of glitter sqm 2642.0 11.30.1.2 Coarse grained granite light Black/light Red/ off White or equivalent with self design/ pattern/crystals of other colors of glitter sqm 2422.0 11.30.1.3 Gray/Pink/Brown or equivalent with various patterns sqm 2153.0 11.30.2 Area of slab upto 0.50 sqm 11.30.2.1 Fine grained granite dark Black/dark Red/ White or equivalent with self design/ pattern/crystals of other colors of glitter sqm 2455.0 11.30.2.2 Coarsegrained granite dark Black/dark Red/ White or equivalent with self design/ pattern/crystals of other colors of glitter sqm 2258.0 11.30.2.3 Gray/Pink/Brown or equivalent with various patterns sqm 2011.0 patterns 143 11.32 144 11.33 11.33.1 Flamed Finish Granite sqm 2542.0 11.33.2 Leather Finish Granite sqm 2809.0 145 11.34 146 11.36 Note: - Deduction shall be made for not mirror polishing according to item no 11.43 147 11.37 148 11.38 11.38.1 10-12 mm thick sqm 1177.0 11.38.2 20 mm thick sqm 1231.0 149 11.39 150 11.4 11.40.1 Marble work meter 164.0 11.40.2 Granite work. meter 269.0 151 11.41 152 11.42 153 11.43 154 11.44 11.44.1 Red sand stone sqm 578.0 11.44.2 White sand stone sqm 578.0 11.44.3 Grey lime stone sqm 578.0 11.44.4 Kota stone sqm 678.0 155 11.47 156 11.48 157 11.49 158 11.52 159 11.53 160 11.54 161 11.55 162 11.56 163 12.63 11.63.1 Fastener with threaded dia 6 mm. each 25.0 11.63.2 Fastener with threaded dia 10 mm. each 29.0 11.63.3 Fastener with threaded dia 12 mm. each 46.0 164 11.66 165 11.72 proper embedding/ laying of inter locking paver blocks into the bedding layer through vibratory compaction byusing plate vibrator, filling the joints with sand and cutting of paver blocks as per required sizeand pattern, finishing and sweeping extra sand including locking with M15 cement concrete in footpath, parks, lawns, drive ways or light traffic parking etc. complete as per manufacturers specifications and direction of Engineer-in-Charge. 11.72.1 80 mm thick C.C. paver block of M-35 grade sqm 805.0 11.72.2 60 mm thick C.C. paver block of M-35 grade sqm 680.0 11.72.3 60 mm thick C.C. paver block of M-30 grade sqm 605.0 166 11.75 including fixing of granite stone door frame with epoxy resin based adhesive including secured to the backing by means of cramps, drilling of hole with rawl plugs and screws 75mm long cleaning etc. complete. Including rubbing, curing, moulding and polishing edges to give high glossy finish and drilling of hole for fixing stainless steel hings, aldrop, towerboltetc complete at all levels as per instruction of Engineer-in-Charge. 11.75.1 Granite Door frame for 100mm thick wall Thickness. metre 1010.0 11.75.2 Granite Door frame for 200mm thick wall Thickness. metre 1512.0 167 11.76 11.76.1 Plain ivory light shade sqm 950.0 Size 600X600mm thickness 9-10mm 11.76.2 Dark shade (terracotta) sqm 1033.0 Size 600X600mm thickness 9-10mm 168 11.77 11. 77.1 Plain ivory light shade sqm 940.0 Size 600X600mm thickness 9-10mm 11. 77.2 Dark shade (terracotta) sqm 1022.0 Size 600X600mm thickness 9-10mm 169 11.8 11.80.1 In light colour and shades as ivory, beige blanco, grey etc. 11.80.1.1 (a) Size 300X300 mm thickness 9-10 mm sqm 934.0 11.80.1.2 (b) Size 600X600mm thickness 9-10mm sqm 1206.0 11.80.1.3 (c) Size 600X600 mm thickness 11-12mm (to be used heavy duty indoor areas of non residencial buildings only such as schools, hostels, libraries hospitals, institutions, offices etc.) sqm 1349.0 11.80.2 In dark colour and shade etc. 11.80.2.1 (a) Size 300X300 mm thickness 9-10 mm sqm 946.0 11.80.2.2 (b) Size 600X600mm thickness 9-10mm sqm 1340.0 11.80.2.3 (c) Size 600X600 mm thickness 11-12mm (to be used in heavy duty indoor areas of non residencial buildings only such as schools, hostels, libraries hospitals, institutions, offices etc.) sqm 1546.0 170 11.81 11. 81.1 In light colour and shades as ivory, beige blanco, grey etc. 11. 81.1.1 (a) Size 300X300 mm thickness 9-10 mm sqm 923.0 11. 81.1.2 (b) Size 600X600mm thickness 9-10mm sqm 1196.0 11. 81.2 In dark colour and shades etc. 11. 81.2.1 (a) Size 300X300 mm thickness 9-10 mm sqm 935.0 11. 81.2.2 (b) Size 600X600mm thickness 9-10mm sqm 1329.0 171 11.82 11. 82.1 For floor glossy/ rustic /stain/matt finished laid on 20mm thick cement mortar 1:4 (1 cement:4sand) 11. 82.1.1 Size 600X600 mm thickness 9-10 mm sqm 1140.0 11. 82.1.2 Size 800X800mm thickness 9-10 mm sqm 1261.0 11. 82.1.3 Size 800X1600mm thickness 9-10 mm sqm 1489.0 11. 82.1.4 Size 1000X1000mm thickness 9-10 mm sqm 1388.0 11. 82.1.5 Size 600X1200 mm thickness 9-10 mm sqm 1235.0 11. 82.1.6 Size 800X1200 mm thickness 9-10 mm sqm 1450.0 11. 82.1.7 Size 1200X1200 mm thickness 9-10 mm sqm 1596.0 11. 82.1.8 Size 1200X1800mm thickness 9-10 mm sqm 1715.0 11. 82.1.9 Size 1200X2400 mm thickness 9-10 mm sqm 2403.0 172 11.83 11. 83.1 For skirting, riser, dado and wall lining etc.glossy/ rustic /stain/mattfinished in all colours and shades 11. 83.1.1 Size 300X600 mm thickness 9-10 mm sqm 1048.0 11. 83.1.2 Size 600X600 mm thickness 9-10 mm sqm 1129.0 11. 83.1.3 Size 800X800mm thickness 11-12mm sqm 1250.0 11. 83.1.4 Size 600X1200 mm thickness 11-12mm sqm 1224.0 11. 83.1.5 Size 800X1200 mm thickness 11-12mm sqm 1440.0 173 11.84 11. 84.1 Area of tiles not less 0.18 sqm 11. 84.1.1 Fine granite dark Black/dark Red/ White with self design/ pattern/crystals of other colors of glitter sqm 2296.0 11. 84.1.2 Course granite light Black/light Red/ off White with crystals of other colors and various patterns sqm 2113.0 11. 84.1.3 Gray/Pink/Brown with various patterns sqm 1879.0 174 11.85 11. 85.1 Area of tiles not less 0.18 sqm 11. 85.1.1 Fine grained granite dark Black/dark Red/ White with self design/ pattern/crystals of other colors of glitter sqm 1775.0 11. 85.1.2 Coarse grained granite light Black/light Red/ off White with crystals of other colors and various patterns sqm 1610.0 11. 85.1.3 Gray/Pink/Brown with various patterns sqm 1404.0 175 11.97 Size 800X1600 mm thickness 8-9 mm Sqm 1778.0 176 11.102 177 11.103 178 12.4 12.4.1 0.80mm thick with zinc coating not less than 275gm/m² meter 500.0 12.4.2 0.63mm thick with zinc coating not less than 275gm/m² meter 431.0 179 12.7 12.7.1 0.80mm thick with zinc coating not less than 275gm/m² meter 459.0 12.7.2 0.63mm thick with zinc coating not less than 275gm/m² meter 402.0 180 12.12 12.12.1 Corrugated serrated adjustable ridges meter 367.0 12.12.2 Plain wing adjustable ridges meter 311.0 12.12.3 Close fitting adjustable ridges meter 420.0 12.12.4 Unserrated adjustable hips meter 506.0 181 12.13 12.13.1 Corrugated apron pieces meter 340.0 12.13.2 Eaves filler pieces meter 232.0 12.13.3 North light curves meter 500.0 12.13.4 ventilator curves meter 622.0 12.13.5 Barge boards meter 623.0 12.13.6 Ridge finials pair 229.0 12.13.7 Special north light curves each 753.0 12.13.8 S type louvers meter 418.0 182 12.14 183 12.15 primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches while transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self-drilling /self-tapping screws of size (5.5x 55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 184 12.16 12.16.1 Ridges plain (500 - 600mm). meter 320.0 12.16.2 Flashings/ Aprons.( Upto 600 mm) meter 284.0 12.16.3 North light curves. meter 341.0 12.16.4 Barge board (Upto 300 mm) meter 274.0 12.16.5 Crimp curve sqm 315.0 12.16.6 Gutter. (600 mm over all girth) meter 781.0 185 12.17 12.17.1 2mm thick corrugated (2.5 or 4.2 or 6) or step-down (2or 3or 6) as specified. sqm 1031.0 12.17.2 2mm thick flat. sqm 955.0 186 12.23 187 12.24 188 12.26 189 12.27 190 12.32 12.32.1 75 mm diameter (minimum wall thickness 1.8mm) metre 136.0 12.32.2 110 mm diameter (minimum wall thickness 2.2mm) metre 238.0 191 12.33 12.33.1 Coupler 12.33.1.1 75 mm (minimum wall thickness 1.8mm) each 67.0 12.33.1.2 110 mm (minimum wall thickness 2.2mm) each 102.0 12.33.2 Single push fit Coupler : 12.33.2.1 75 mm (minimum wall thickness 1.8mm) each 121.0 12.33.2.2 110 mm (minimum wall thickness 2.2mm) each 94.0 12.33.3 Single tee with door 12.33.3.1 75x75x75 mm (minimum wall thickness 1.8mm) each 106.0 12.33.3.2 110x110x110 mm (minimum wall thickness 2.2mm) each 176.0 12.33.4 Single tee without door 12.33.4.1 75x75x75 mm (minimum wall thickness 1.8mm) each 106.0 12.33.4.2 110x110x110 mm (minimum wall thickness 2.2mm) each 163.0 12.33.5 Bend 87.5° 12.33.5.1 75 mm bend (minimum wall thickness 1.8mm) each 78.0 12.33.5.2 110 mm bend (minimum wall thickness 2.2mm) each 112.0 12.33.6 Shoe (Plain) 12.33.6.1 75 mm Shoe (minimum wall thickness 1.8mm) each 69.0 12.33.6.2 110 mm Shoe (minimum wall thickness 2.2mm) each 99.0 192 12.34 12.34.1 75 mm (minimum wall thickness 1.8mm) each 97.0 12.34.2 110 mm (minimum wall thickness 2.2mm) each 114.0 hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in adirection perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes, finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturers specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with 12.58.1 10mm thick plaster of Paris (gypsum anhydrous) sheet 10mm thick pop board. 12.58.1.1 Flat surfaces sqm 676.0 12.58.1.2 Curved surfaces sqm 748.0 12.58.1.3 Sunk or raised mouldings sqm 175.0 12.58.1.4 Extra for providing in the plaster of Paris (Gypsum anhydrous) ceiling above 5 metre height from floor level. sqm per meter height 59.0 12.58.2 12.5 mm thick tapered edge gypsum board 12.58.2.1 Plain board conforming to IS: 2095- Part I: 2011 (Board with BIS certification marks). sqm 750.0 12.58.2.2 Fire resistant Glass ReinforcedGypsum (GRG) board conforming to IS: 2095- (Part 3) : 1996 (Board with BIS certification marks) sqm 866.0 12.58.2.3 12.5mm thick moisture resistant gypsum plasterboards Moistbloc as per BS EN 520 confirming to water absorption class H1 with total water absorption < 5%, Green Pro certified by CII sqm 920.0 12.58.2.4 Fully Perforated Gypsum Plaster Board having approx. 15 % perforated area with perforation size and pattern as approved by the Engineer-in-charge and as per manufacturersspecification, with all 4 side tapered and backed by acoustical tissue with NRC value not less than 0.60. sqm 1277.0 12.58.3 8 mm thick Calcium Silicate Board made with Calcareous and Siliceous materials reinforced with cellulose fiber manufactured throughautoclaving process. sqm 1150.0 193 13.1 13.1.1 1:4 (1 cement : 4 sand) sqm 173.0 13.1.2 1:6 (1 cement : 6 sand) sqm 160.0 194 13.2 13.2.1 1:4 (1 cement : 4 sand) sqm 184.0 13.2.2 1:6 (1 cement : 6 sand) sqm 168.0 195 13.3 13.3.1 1:4 (1 cement : 4 sand) sqm 245.0 13.3.2 1:6 (1 cement : 6 sand) sqm 225.0 196 13.4 13.4.1 1:3 (1 cement : 3 sand) sqm 210.0 13.4.2 1:4 (1 cement : 4 sand) sqm 203.0 197 13.5 13.5.1 1:3 (1 cement : 3 sand) sqm 236.0 13.5.2 1:4 (1 cement : 4 sand) sqm 220.0 198 13.13 199 13.14 200 13.15 13.15.1 Exterior walls of height more than 10 m from ground for every additional height of 3 m or part thereof sqm 34.0 13.15.2 Interior walls of height more than 6 m from floor level for every additional height of 3 m or part thereof sqm 22.0 201 13.16 13.16.1 In one coat sqm 11.0 13.16.2 In two coats sqm 18.0 202 13.17 13.17.1 In one coat sqm 158.0 13.17.2 In two coats sqm 260.0 203 13.18 13.18.1 Spherical ceiling sqm 42.0 13.18.2 Groined ceiling sqm 47.0 13.18.3 Flewing soffits sqm 28.0 204 13.38 205 13.39 13.39.1 Providing and applying plaster of paris punning of 10 mm average thickness over plastered surface to prepare the surface even and smooth complete. sqm 130.0 13.39.2 Extra for making 12mm flute grove with 6 mm depth to prepare the surface even and smooth complete. metre 70.0 206 13.41 207 13.43 208 13.44 209 13.45 210 13.46 211 13.47 13.47.1 One coat. sqm 20.0 13.47.2 Two coats. sqm 32.0 212 13.48 13.48.1 One coat. sqm 37.0 13.48.2 Two coats. sqm 56.0 213 13.49 214 13.51 215 13.52 216 13.53 217 13.54 218 13.54.1 219 13.54.2 220 13.54.3 221 13.55 13.55.1 One coat sqm 63.0 13.55.2 Two coats sqm 101.0 222 13.64 223 13.65 224 13.66 13.66.1 One coat. sqm 35.0 13.66.2 Two coats. sqm 53.0 225 13.68 226 13.71 227 13.77 228 13.8 13.80.1 0.8-1.2mm thickness sqm 368.0 13.80.2 2.0-2.5mm thickness sqm 338.0 229 13.81 effective for 90 Days(03 Months) . 230 13.103 Note:- Applicable to item No. 13.1 to item No. 13.10 231 13.105 13.105.1 Standard pattern and design wallpaper Sqm 615.0 13.105.2 3D pattern and design wallpaper Sqm 750.0 13.105.3 Customize design wallpaper Sqm 1145.0 232 14.5 14.5.1 Float glass panes of thickness 4 mm sqm 679.0 14.5.2 Float glass panes of thickness 5.5 mm sqm 759.0 233 14.6 14.6.1 Float glass panes of thickness 4 mm sqm 801.0 14.6.2 Float glass panes of thickness 5.5 mm sqm 882.0 234 14.7 14.7.1 Float glass panes of thickness 4 mm sqm 697.0 14.7.2 Float glass panes of thickness 5.5 mm sqm 778.0 235 14.8 14.8.1 2nd class teak wood fillets meter 30.0 14.8.2 Haldu/Bija/Kail wood fillets. meter 26.0 236 14.11 237 14.24 238 14.27 239 14.28 240 14.29 241 14.31 242 14.36 243 14.37 244 14.38 245 14.39 246 14.48 247 14.49 14.49.1 Old work (one or more coats applied @ 2.20 kg/10 sqm) over priming coat of primer applied @ 0.80 liters/10 sqm complete including cost of Priming coat. sqm 42.0 14.49.2 Old work (one or more coats @ 2.20 kg/10 sqm) complete. sqm 30.0 248 14.51 14.51.1 Old work (Two or more coat applied @ 1.67 ltr/ 10 sqm) on existing cement paint surface). sqm 87.0 14.51.2 Old work (One or more coat applied @ 0.90 ltr/10 sqm). sqm 52.0 249 14.52 14.52.1 Old work (Two or more coats applied @ 1.43 ltr/ 10 sqm) over existing cement paint surface. sqm 65.0 14.52.2 Old work (one or more coats applied @ 0.83 ltr/10 sqm). sqm 41.0 250 14.53 14.53.1 One or more coats applied on walls @ 0.85 ltr/10 sqm. sqm 58.0 251 14.62 14.62.1 (one or more coats) sqm 9.0 14.62.2 (two or more coats) sqm 11.0 252 15.2 15.2.1 Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix). cum 578.0 15.2.2 Nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix). cum 356.0 253 15.6 15.6.1 In lime mortar with old mughal bricks. cum 421.0 15.6.2 In lime mortar. cum 202.0 15.6.3 In cement mortar. cum 487.0 254 15.7 15.7.1 From brick work in lime mortar. 1000 nos 1254.0 15.7.2 From brick work in cement mortar. 1000 nos 1560.0 255 15.8 15.8.1 In lime mortar. cum 275.0 15.8.2 In cement mortar. cum 582.0 256 15.13 257 15.14 15.14.1 Of area 3 sq. metres and below. each 85.0 15.14.2 Of area beyond 3 sq. metres. each 117.0 258 15.15 15.15.1 Of area 3 sq. metres and below. each 33.0 15.15.2 Of area beyond 3 sq. metres. each 44.0 259 15.47 260 15.48 261 15.49 262 15.51 15.51.1 Rectangular manhole 90x80 cm and 45 cm deep each 611.0 15.51.2 Rectangular manhole 120x90 cm and 90 cm deep. each 1069.0 15.51.3 Rectangular arch type manhole 140x90cm and 2.45m deep. each 2023.0 15.51.4 Circular manhole 122 cm diameter and 1.68 m deep each 1553.0 263 15.52 15.52.1 Rectangular manhole 90x80 cm and beyond 45 cm depth. each 486.0 15.52.2 Rectangular manhole 120x90 cm and beyond 90 cm depth. each 579.0 15.52.3 Rectangular arch type manhole 140x90 cm and beyond 2.45m deep (upto 4.25 m depth). each 468.0 15.52.4 Circular manhole 122 cm diameter and beyond 1.68 m deep (upto 2.29 m depth). each 322.0 264 15.64 265 17.1 17.1.1 White Vitreous china Orissa pattern W.C. pan of size 580x440mm with integral type foot rests. each 2995.0 266 17.2 17.2.1 W.C. pan with ISI marked white solid plastic seat and lid. each 3036.0 17.2.2 W.C. pan with ISI marked black solid plastic seat and lid. each 3013.0 267 17.3 17.3.1 W.C. pan with ISI marked white solid plastic seat and lid. each 4613.0 17.3.2 W.C. pan with ISI marked black solid plastic seat and lid. each 4590.0 268 17.11 17.11.2 White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap. each 2187.0 17.11.3 White Vitreous China Wash basin size 550x400 mm with a pair of 15 mm C.P. brass pillar tap. each 1938.0 17.11.4 White Vitreous China Flat back wash basin size 550x400 mm with single 15 mm C.P. brass pillar tap. each 1664.0 17.11.5 White Vitreous China Angle back wash basin size 600x480 mm with single 15 mm C.P. brass pillar tap. each 1775.0 269 17.12 270 17.14 17.14.1 Kitchen sink with drain board 17.14.1.1 510x1040 mm bowl depth 250mm. each 8074.0 17.14.1.2 510x1040 mm bowl depth 225mm. each 7609.0 17.14.1.3 510x1040 mm bowl depth 200mm. each 7493.0 17.14.1.4 510x1040 mm bowl depth 178mm. each 5286.0 17.14.2 Kitchen sink without drain board 17.14.2.1 610x510 mm bowl depth 200 mm. each 4583.0 17.14.2.2 610x460 mm bowl depth 200 mm. each 4351.0 17.14.2.3 470x420 mm bowl depth 178 mm. each 3422.0 271 17.22 17.22.1 White each 945.0 17.22.2 coloured each 1037.0 272 17.24 17.24.1 White each 456.0 17.24.2 Black each 433.0 17.24.3 Coloured (other than black and white) each 688.0 273 17.25 274 17.6 17.60.1 75 mm each 33.0 17.60.2 110 mm each 50.0 275 17.61 276 17.64 17.64.1 Semi rigid pipe 17.64.1.1 32 mm dia each 87.0 17.64.1.2 40 mm dia each 98.0 17.64.2 Flexible pipe (only in residential & complaxes) 17.64.2.1 32 mm dia each 87.0 17.64.2.2 40 mm dia each 98.0 277 17.65 278 17.67 279 17.67 17.68.1 Circular shape 450mm dia. each 806.0 17.68.2 Rectangular shape 453x357mm each 642.0 17.68.3 Oval shape 450x350mm (outer dimensions) each 697.0 17.68.4 Rectangular shape 1500x450 mm each 1311.0 280 17.69 281 17.7 17.70.1 C.P. brass each 340.0 17.70.2 Vitreous china each 324.0 282 17.74 283 17.75 284 17.76 285 18.6 18.6.1 Internal work - Exposed on wall 18.6.1.1 15 mm nominal outer dia .Pipes metre 129.0 18.6.1.2 20 mm nominal outer dia .Pipes metre 153.0 18.6.1.3 25 mm nominal outer dia .Pipes metre 177.0 18.6.1.4 32 mm nominal outer dia .Pipes metre 254.0 18.6.1.5 40 mm nominal outer dia .Pipes metre 354.0 18.6.1.6 50 mm nominal outer dia .Pipes metre 528.0 18.6.2 Concealed work including cutting chases and making good the walls etc. 18.6.2.1 15 mm nominal outer dia .Pipes metre 207.0 18.6.2.2 20 mm nominal outer dia .Pipes metre 234.0 18.6.2.3 25 mm nominal outer dia .Pipes metre 288.0 18.6.2.4 32 mm nominal outer dia .Pipes metre 360.0 286 18.7 External Work 18.7.1 15 mm nominal outer dia .Pipes metre 122.0 18.7.2 20 mm nominal outer dia .Pipes metre 141.0 18.7.3 25 mm nominal outer dia .Pipes metre 185.0 18.7.4 32 mm nominal outer dia .Pipes metre 238.0 18.7.5 40 mm nominal outer dia .Pipes metre 324.0 18.7.6 50 mm nominal outer dia .Pipes metre 498.0 18.7.7 62.50 mm nominal inner dia .Pipes. metre 1429.0 18.7.8 75 mm nominal inner dia .Pipes. metre 2018.0 18.7.9 100mm nominal inner dia .Pipes. metre 2791.0 18.7.10 150 mm nominal inner dia .Pipes. metre 3358.0 287 18.13 18.13.1 25 mm nominal bore each 428.0 18.13.2 32 mm nominal bore. each 500.0 18.13.3 40 mm nominal bore each 584.0 18.13.4 50 mm nominal bore each 749.0 288 18.14 18.14.1 15 mm nominal bore each 316.0 18.14.2 20 mm nominal bore each 431.0 18.14.3 25 mm nominal bore each 499.0 289 18.17 18.17.1 30 cm length 18.17.1.1 15 mm nominal bore each 88.0 18.17.1.2 20 mm nominal bore each 129.0 18.17.2 45 cm length 18.17.2.1 15 mm nominal bore each 149.0 18.17.2.2 20 mm nominal bore each 184.0 290 18.18 18.18.1 With common burnt clay bricks of 25 kg /sqcm compressive strength. each 916.0 18.18.2 With well burnt flyash bricks of 50 kg/sqm compressive strength. each 870.0 291 18.28 292 18.29 18.29.1 15 mm nominal bore each 306.0 18.29.2 20 mm nominal bore each 338.0 293 18.3 18.30.1 15 mm nominal bore each 318.0 18.30.2 20 mm nominal bore each 344.0 294 18.31 295 18.32 296 18.33 297 18.34 298 18.35 299 18.36 300 18.37 301 18.38 302 18.39 303 18.41 304 18.42 305 18.43 18.43.1 100 mm diameter each 806.0 18.43.2 150 mm diameter each 922.0 18.43.3 200 mm diameter each 1336.0 306 18.64 307 18.65 308 18.67 309 18.68 18.68.1 300 mm long each 450.0 18.68.2 600 mm long each 650.0 310 19.4 19.4.1 110 mm diameter OD (min. wall thickness 3.2mm) metre 234.0 19.4.2 160 mm diameter OD (min. wall thickness 4.0 mm) metre 477.0 19.4.3 200 mm diameter OD (min. wall thickness 4.9 mm) metre 751.0 19.4.4 250 mm diameter OD (min. wall thickness 6.2mm) metre 972.0 19.4.5 300 mm diameter OD (min. wall thickness 7.7mm) metre 1232.0 311 19.5 19.5.1 110 mm diameter PVC. pipe metre 576.0 19.5.2 160 mm diameter PVC. pipe metre 704.0 19.5.3 200 mm diameter PVC. pipe metre 821.0 19.5.4 250 mm diameter PVC. pipe metre 949.0 19.5.5 300 mm diameter PVC pipe metre 1078.0 312 19.6 19.6.1 110 mm diameter PVC. pipe metre 274.0 19.6.2 160 mm diameter PVC. pipe metre 444.0 19.6.3 200 mm diameter PVC. pipe metre 521.0 19.6.4 250 mm diameter PVC. Pipe metre 607.0 19.6.5 300 mm diameter PVC pipe metre 700.0 313 19.7 19.7.1 100x100 mm size P type 19.7.1.1 With well burnt bricks each 1764.0 19.7.1.2 With Sewer bricks conforming to IS : 4885 each 1668.0 19.7.2 150 x 100 mm size P type. 19.7.2.1 With well burnt bricks each 1803.0 19.7.2.2 With sewer bricks conforming to IS : 4885 each 1707.0 19.7.3 180x150 mm size P type 19.7.3.1 With well burnt bricks each 1913.0 19.7.3.2 With Sewer bricks conforming to IS : 4885 each 1818.0 314 19.9 19.9.1 Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions total weight of cover and frame to be notless than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : 19.9.1.1 With well burnt bricks each 7997.0 19.9.1.2 With Sewer bricks conforming to IS : 4885 each 7747.0 19.9.2 Inside size 120x90 cm and 90 cm deep including C.I. cover with frame (medium duty) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg (weight of cover 58 kg and weight offrame 58 kg) : 19.9.2.1 With well burnt bricks each 18086.0 19.9.2.2 With Sewer bricks conforming to IS : 4885 each 17402.0 19.9.3 Inside size 120x90 cm and 90 cm deep including C.I. cover with frame (heavy duty) 560 mm internal diameter, total weight of cover and frame to be not less than 208 kg (weight of cover 108 kg and weight of frame 100 kg) 19.9.3.1 With well burnt bricks each 21816.0 19.9.3.2 With Sewer bricks conforming to IS : 4885 each 21228.0 315 19.1 19.10.1 Size 90x80 cm 19.10.1.1 With well burnt bricks metre 6176.0 19.10.1.2 With Sewer bricks conforming to IS : 4885 metre 5448.0 19.10.2 Size 120x90 cm 19.10.2.1 With well burnt bricks metre 7380.0 19.10.2.2 With Sewer bricks conforming to IS : 4885 metre 6512.0 316 19.12 19.12.1 With well burnt bricks metre 5257.0 19.12.2 With Sewer bricks conforming IS : 4885 metre 4648.0 317 21.1 21.1.1 For fixed portion. 21.1.1.1 Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC15) kg 378.0 21.1.1.2 Powder coated aluminium (minimum thickness of powder coating 50 micron) kg 416.0 21.1.1.3 Polyester powder coated aluminium (minimum thicknessof polyester powder coating 50 micron) kg 426.0 21.1.2 For shutters of doors, windows and ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings whereverrequired including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately). 21.1.2.1 Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC15) kg 446.0 21.1.2.2 Powder coated aluminium (minimum thickness of powder coating 50 micron) kg 484.0 21.1.2.3 Polyester powder coated aluminium (minimum thicknessof polyester powder coating 50 micron) kg 494.0 21.1.3 Deduct for not providing EDPM rubber/neoprene gasket all around. kg 80.0 318 21.2 21.2.1 Pre-laminated particle board with decorative lamination on one side and balancing lamination on other side. sqm 802.0 21.2.2 Pre-laminated particle board with decorative lamination on both sides. sqm 907.0 319 21.3 21.3.1 With float glass panes of 4.0 mm thickness (weight not less than 10 kg/sqm) sqm 774.0 21.3.2 With float glass panes of 5.0 mm thickness (weight not less than sqm 948.0 12.50 kg/sqm ) 21.3.3 With float glass panes of 8 mm thickness (weight not less than 20 kg/sqm ). sqm 1182.0 320 21.5 21.5.1 With stainless steel cover plate - minimum 1.25 mm thickness each 1890.0 21.5.2 With brass cover plate - minimum 1.25 mm thickness. each 2072.0 321 21.16 21.16.1 Anodized (AC15 ) aluminium each 62.0 21.16.2 Powder coated minimum thickness 50 micron aluminium each 65.0 21.16.3 Polyester powder coated minimum thickness 50 micron aluminium. each 69.0 322 21.17 323 21.18 324 21.19 325 21.21 326 21.22 327 21.23 328 21.24 329 21.32 330 22.6 a) After surface preparation, first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. b) Laying second layer of Fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm. c) Third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/sqm mixed with water proofing cement compound @ 0.670 kg/sqm and sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30cm on parapet wall and tucked into groove in parapet all around. 331 22.14 22.14.1 Cement concrete 1:2:4 (1 cement : 2 sand : 4 graded stone aggregate 20 mm nominal size) cum 6569.0 22.14.2 Cement mortar 1:3 (1 cement : 3 sand) cum 9308.0 22.14.3 Cement mortar 1:4 (1cement : 4 sand) cum 8437.0 332 25.1 25.1.1 White Vitreous china Anti germ Fluoro-Polymer coated Orissa Pattern W. C. Pan of Size 440X575X250mm With integral foot rests. (Premium Range) each 4726.0 25.1.2 White Vitreous china Anti germ Fluoro-Polymer coated Orissa pattern W. C. pan of size 410X515X255 mm with integral foot rests.(Premium Range) each 4392.0 333 25.2 25.2.1 Anti-germ Fluoro-Polymer Coated (nano coating) European W. C. pan Size 360X545X395 with solid poly propelyne made soft closing seat cover (Premium Range) each 9788.0 25.2.2 Anti-germ Fluoro-Polymer Coated Water Closet European type W. C. pan size 360X475X395 mm with solid poly propelyne made soft closing seat cover (Premium Range) each 8742.0 334 25.3 25.3.1 Anti germ Fluoro-Polymer Coated (Nano coating) Wall hung water closet Size 380X520X375 mm with solid poly propelyne made soft closing seat cover (Premium Range) each 26412.0 25.3.2 Anti germ Fluoro-Polymer Coated (Nano coating) Wall hung water closet size 390X570X365 mm with solid poly propelyne made, soft closing seat cover (Premium Range) each 23559.0 25.3.3 Anti germ Fluoro-Polymer Coated (Nano coating) Wall hung water closet size 360 x 500 x 330mm with solid poly propelyne made, soft closing seat cover (Premium Range) each 21099.0 25.3.4 Anti germ Fluoro-Polymer Coated (Nano coating) Wall hung water closet size 360 x 500 x 330mm or greater size with solid poly propelyne made, soft closing seat cover (Premium Range) each 18838.0 335 25.4 25.4.1 Anti germ Fluoro-Polymer Coated couple water closet Size 420X710X810mm with solid poly propelyne made soft closing seat cover. (Premium Range) each 28103.0 25.4.2 Anti germ Fluoro-Polymer Coated couple water closet Size 380X610X805mm with solid poly propelyne made soft closing seat cover. (Premium Range) each 19275.0 25.4.3 Anti germ Fluoro-Polymer Coated couple water closet Size 370 x 640 x 760mm with solid poly propelyne made soft closing seat cover. (Premium Range) each 18952.0 25.4.4 Anti germ Fluoro-Polymer Coated couple water closet Size 375X650X800 mm with solid poly propelyne made soft closing seat cover. (Premium Range) each 18023.0 336 25.5 25.5.1 Anti germ Fluoro-Polymer Coated Single Piece W.C. Pan Size 370X695X795mm with solid poly propelyne made soft closing seat cover.(Premium Range) Each 34317.0 25.5.2 Anti germ Fluoro-Polymer Coated Single Piece W.C. Pan Size 370X695X795mm with solid poly propelyne made soft closing seat cover.(Premium Range) each 25954.0 25.5.3 Anti germ Fluoro-Polymer Coated Single PieceW.C. Pan Size 385X720X710mm with solid poly propelyne made soft closing seat cover.(Premium Range) each 22237.0 25.5.4 Anti germ Fluoro-Polymer Coated Single Piece W.C. Pan Size 370X695X795mm with solid poly propelyne made soft closing seat cover.(Premium Range) each 19450.0 337 25.6 25.6.1 Anti germ Fluoro-Polymer Coated extended wall hung type couple closet Size 380X650X730mm with solid poly propelyne made soft closing seat cover (Premium Range) each 13365.0 25.6.2 Providing and fixing white vitreous china made Anti germ fluoro-polymer coated extended wall hung type couple closet Size 375X360X750mm along with dual flushing cistern flushing capacity 3 & 6 litre. (Premium Range) each 10670.0 338 25.7 25.7.1 White Vetrious China Anti germ Fluoro-Polymer Coated Wash Basin Size 595X435X185 mm with basin mounted pressmatic pillar cock auto closing system (decol technology). (Premium Range) each 16581.0 339 25.8 25.8.1 Providing and fixing white vitreous china type Anti germ fluoro-polymer coated counter top wash basin Size 570x415x200mm with 15 mm C. P. wall mounted pressmatic Pillar cock auto closing system with square wall flance & spout complete (decol technology). (Premium Range) each 14543.0 25.8.2 Providing and fixing white vitreous china type Anti germ fluoro-polymer coated counter top wash basin Size 570X820X195mm with 15 mm C. P. Table Top pressmatic Pillar cock auto closing system (decol technology). (Premium Range) each 13614.0 340 25.9 25.9.1 White Vetrious China Anti germ Fluoro-Polymer Coated Wash Basin Size 615x415x150mm with wall mounted single lever concealed basin mixture (cartridge size 32mm.) (Premium Range) each 15591.0 25.9.2 Providing and fixing white vitreous china type Anti germ fluoro-polymer coated counter top wash basin Size 600x400x185mm with 15 mm C. P. wall mounted single lever concealed basin mixture. (Premium Range) each 14940.0 341 25.1 25.10.1 White Vetrious China Anti germ Fluoro-Polymer Coated Wash Basin Size 595x435x185mm with Table mounted single lever Tall boy basin mixture, (cartridge size 32mm.) (Premium Range) each 18585.0 25.10.2 White vitreous china type Anti germ fluoro- polymer coated counter top wash basin Size 530x420x140mm with tall boy basin mixture, (cartridge size 32 mm). (Premium Range) each 16785.0 342 25.11 25.11.1 White Vitreous China Anti germ Fluoro-Polymer Coated Urinal Size 340x325x650 mm. (Premium Range) each 14544.0 25.11.2 Providing and fixing white vitreous china Flat Back Anti germ Fluoro-Polymer Coated urinal size 475X315X715 mm top inlet with fixing accessories (Inbuilt spreaders, Inbuilt Bottle trape and inbuilt ceramic Waste coupling) with 15mm Brass made Pressmatic auto closing open urinal flush valve with wall flange (Decol technology, 400000 operation warranted) complete including painting of fittings and brakets, cutting and making good the wall and floors wherever required : each 13336.0 25.11.3 Providing and fixing white vitreous china Flat Back Anti germ Fluoro-Polymer Coated urinal back inlet with fixing accessories (Inbuilt spreaders, Inbuilt Bottle trape and inbuilt ceramic Waste coupling) Size 385X325X635 mm with Concealed sensotronic flushing valve for urinal complete set with installation box with control cock complete including painting of fittings and brakets, cutting and making good the wall and floors wherever required : URS-WHT-13253N & PRS-CHR-073 each 10641.0 343 25.12 25.12.1 White Vetrious China Anti germ Fluoro-Polymer Coated Urinal Size 340x325x650 mm with sensotronic concealed type flushing valve battery & electrical oprated type (9V transformer) for urinal complete set with installation box with control cock. (Premium Range) each 23927.0 25.12.2 White Vetrious China Anti germ Fluoro-Polymer Coated Urinal size 385x325x635 mm with concealed sensotronic flushing valve for urinal complete set with installation box, (Premium Range) each 20025.0 344 25.13 25.13.1 White Vetrious China Anti germ Fluoro-Polymer Coated Urinal Size 480 X 300X740 mm with 15mm Brass made pressmatic auto closing concealed urinal flush valve with wall flange (Decol technology, 400000 operation warranted). (Premium Range) each 18491.0 345 25.14 346 25.14.1 25.14.2 Providing and fixing white vitreous china flat back Anti germ fluoro-polymer coated Urinal size 475x315x715 mm (Inbuilt spreaders, bottle trap and ceramic waste coupling) with inbuilt sensor battery & electrical oprated type (9V transformer) for flushing. (Premium Range) each 22998.0 347 25.15 348 25.16 349 25.17 350 25.18 351 25.19 352 25.21 353 25.22 354 25.23 355 25.24 356 25.25 357 25.26 358 25.27 359 25.28 360 25.29 361 25.31 362 25.32 363 25.33 364 25.34 365 25.35 366 25.36 367 25.37 368 25.38 369 25.39 370 25.41 371 25.42 372 25.43 373 25.44 374 25.45 375 25.46 376 25.47 377 25.48 378 25.49 379 25.51 380 25.52 381 25.53 382 25.54 383 25.55 384 25.56 385 25.57 386 25.58 387 25.59 388 25.61 389 25.62 390 25.63 vitreous china type Anti germ fluoro-polymer coated wall mounted wash basin with C.I. brackets, C. P. brass single lever basin mixer, 15mm quarter turn angular stop cock, 32 mm C.P. brass waste coupling length 130mm and 32 mm C.P. brass bottle trap size 200x300mm i/c cutting and making good the wall and floors wherever required, all fittings and fixtures etc. complete . (Premium Range) 25.63.1 white Vetrious china Anti germ fluoro-polymer coated wall mounted wash basin size 620x480x185 mm. (Premium Range) each 14729.0 25.63.2 white Vetrious china Anti germ fluoro-polymer coated wall mounted wash basin size 570x470x190 mm. (Premium Range) each 15100.0 25.63.3 white Vetrious china Anti germ fluoro-polymer coated wall hung intergrated wash basin size 495x400x365 mm. (Premium Range) each 18490.0 391 25.64 25.64.1 white Vetrious china Anti germ fluoro-polymer coated wall mounted wash basin size 620x480x185 mm. (Premium Range) each 10617.0 Note- Schedule of items includes all the items required for maintainance of buildings regarding A/R, S/R MOW, Deposit & Other Works as per SCHEDULE OF RATES FOR BUILDING WORKS inforce from 01/01/2024, issued by Project Director, Public Works Department (PIU) M.P. Bhopal. Sub Engineer Sub Divisional OfficerSurvey Sub Division.P.W.D. Bhopal Executive EngineerMaintanance Division No.2P.W.D. Bhopal
Contract Date: Apr 23, 2026 Contract Value : 21.93 Lakh
Government Departments No of Bidders 5
Madhya Pradesh View Result →
23.
Defence #11306500 AOC
Tender for Taking Down Cement Plaster On Brick, Concrete Stone Surfaces Etc Including Raking Out Joints, Hacking For Key, Scrubbing Down With Water Etc. Complete All As Specified And Directed , M & L 10 Mm Thick Rendering On Cement Mortar 1:6 On Brick Or Concrete Surfaces Finished Even & Smooth Without Using Extra Cement Complete All As Specified And Directed , Material And Labour For 10Mm Thick Rendering In Cement Mortar (1:3) On Brick Or Concrete Surfaces Of Ceiling Finshed Even And Smooth Without Using Extra Cement. Complete All As Specified And Directed , M & L For 15Mm Thick Rendering In Cement Mortar 1:4 On Brick , Concrete And Roof Surface With Wpc @ 200Ml Per 50Kg By Weight Of Cement Finishing The Surfaces Even & Fair, Complete All As Directed.(Wpc Will Be Measured And Paid Separately). , Supply Only Liquid Water Proofing Compound. , Material And Labour For Complete Removal Of Existing Treatment For Old Wall Surface, Including Washing Down And Stopping Of Distempered Surfaces And Applying Two Coat Of Distempered Oil Emulsion Over 1Mm Thick Wall Care Putty All As Specified And Directed. , Material And Labour For 1 Mm Thick Wall Care Putty On Wall All As Specified And Directed. , Material And Labour For Preparation Of Old Painted Steel Surfaces Of Any Description Over 10 Cm Width Or Girth And Applying One Coat Of Synthetic Enamel Paint All As Specified And Directed. , Material And Labour For Preparation Of Old Previously Treated Plastered Surface Of Ceilings Including Cornices Etc, And Cleaning By Brooming Down And Applying Two Coat Of White Wash On Ceilig All As Specified And Directed. , Material And Labour For Preparation Of Old Distempered Surface Of Walls Including Washing Down And Stopping Of Distempered Surfaces And Applying One Coat Of Distempered Oil Emulsion All As Specified And Directed. , M & L For Preparation Of New External Plasterd Surface Of Wall And Ceiling Apply Of Birla White Putty, Make The Surface Smooth By Rubbing With Emary Paper And Applying Two Coats Of Weather Proof Paint Over A Coat Of Water Thinkable Cement Primer Complete All As Specified And Directed , M & L For Preparation Of Old Plasterd Surface Of Wall And Ceiling Apply Make The Surface Smooth By Rubbing With Emary Paper And Applying One Coats Of Weather Proof Paint Complete All As Specified And Directed , M & L For Preparing New Wooden Surfaces Of Any Description, Not Otherwise Described Over 10 Cm In Width Or Girth And Applying Two Coats Of Synthetic Enamel Paint Over A Coat Of Pink Primer, Complete All As Specified And Directed. , M&L Preparing New Plastered Surfaces Of Wall And Applying Two Coats Of Acrylic Distemper/ Distemper Oil Emulsion (Obd), Over A Coat Of 1Mm Thick Wall Care Putty All As Specified Including Preperation Of Surfaces Complete All As Specified And Directed , M&L Preparing Newly Plastered Surfaces Of Ceilings And Applying Three Coats Of White Wash, Complete All As Specified And Directed. , M&L For Writing Letters Or Figureswith Synthetic Enamel Paint (Block. Roman, Italic Or Indian) N Exc. 30 Cm High,Complete All As Directed. , Dismantling Of Wall And Ceiling Boards Any Type And Thickness Including Cover Fillets, Complete All As Specified And Directed. , Supply And Fix 600Mmx600mmx4mm Thick ‘E Board Classic (Make-Everest Industries Ltd) As In False Ceiling Including Supply And Fixing Gi ‘Tee Grid Frame Work Made Of Special Section Of M.S Galvanized Sheet 0.30Mm Thick , Bottom Portion Painted With Cellular Nitro Painting, Warping The Suspending Wire Around The Existing Wooden/Steel Purlin /Rafter For Suspending Grid Frame Work Of Size 605Mmx605mm Suspended With 4 Mm Dia Gi Wire @ 1200Mm C/C On Main Tee And Fixed To T-Grid With The Help Of Level Clip Or As Per Manufacturer Direction. The Section Consisting Of Main Tee 37Mmx24mmx0.60Mm, Cross Runner Tee 37Mmx24mmx0.60Mm And Perimeter Angle Of 24Mmx24mmx0.50Mm Thick. Perimeter Angle To Be Fixed To Wall With Gi Screw Of 40Mm Long @ 450 Mm C/C Along The Perimeter Of Wall Including Applying Two Coats Of Distemper Oil Emulsion Complete All As Specified And Directed , Dismantling Floor, Hearth Or Wall Tiling Including Cement Mortar Bedding (But Not Backing), And Rubbish Off From The Site, Complete All As Directed. , M&L For 25 Mm Thick Plain Cement Concrete 1:2:4 Type B1 (Using 20 Mm Graded Stone Aggregate) As In Sub Floor Finishing Cement Concrete Surface Even And Smooth Using Extra Cement Complete All As Specified And Directed , M&L For 15 Mm Thick Screed Bed In Cm 1:4 For Laying Floor Tiles, Complete All As Specified And Directed , M&L For Non-Skid Ceramic Coloured Tiles 7 To 8 Mm Thick (Square/Rectangular) Area Of Each Tile Exceeding 0.11 Sqm But Not Exceeding .18 Sqm, In Floors Etc Set And Jointed In Neat Cement Slurry And Pointed In White/Coloured Cement To Match The Shade, Complete All As Specified And Directed. , M&L For Light Shade Virified Ceramic Tiles 10 Mm Thick (Square/ Rectangular) Polished, Area Of Each Tiles Not Exceeding 0.36 Sqm, In Floors Etc. Set And Jointed In Neat Cement Slurry And Pointed In White Or Coloured Cement To Match, Complete All As Specified And Directed. , M&L For Dark Shade Virified Ceramic Tiles 10 Mm Thick (Square/ Rectangular) Polished, Area Of Each Tiles Not Exceeding 0.36 Sqm, In Floors Etc. Set And Jointed In Neat Cement Slurry And Pointed In White Or Coloured Cement To Match, Complete All As Specified And Directed. , M&L For Light Shade Virified Ceramic Tiles 10 Mm Thick (Square/ Rectangular) Polished, Area Of Each Tiles Not Exceeding 0.36 Sqm, As In Skirting, Dados And Riser To Steps Etc. Set And Jointed In Neat Cement Slurry And Pointed In White Or Coloured Cement To Match, Complete All As Specified And Directed. , M & L For 10Mm Thick Rendering In Cm 1:4 On Fair Faces Of Brick Work Or Concrete Surfaces Finished Rough To Receive Tiles . , M & L For 450X300x7mm Mm Thick Glazed Coloured Ceramic Tiles On Vertical Surface Of Wall Set And Jointed In Neat Cement Slurry And Pointed In White/Coloured Cement To Match The Shade. , Demolition Of Stone Slabs And Tiles Of Any Description Or Thickness In Floors, Aprons Etc And Removal Of Rubbish From Site, Complete All As Specified And Directed.. , M&L18- 20 Mm Thick Granite (Of Any Type) Work (Table Rubbed And Polished) In Cooking Platforms In Cm 1:4 Including Pointing In White Cement 1:2 Using Marble Dust With Admixture Of Pigment To Match With Shade Of Granite Including Moulding Of Edged,Complete All As Specified And Directed. , M&L For 20Mm Thick Granite (Of Any Type) Work (Table Rubbed And Polished) For Wall Lining (Veneering To Wall) 12Mm Thick In Cement Mortar (1:3) And Pointing With White Cement (1:2) Using Marble Dust With Admixture Of Pigment To Match With Shade Of Granite Including Moulding Of Edges If Reqd, Complete All As Specified And Directed. , Demolition Of Precast Cement Concrete Articles And Precast Concrete Block Walling Built In Cement Mortar, Comlpete All As Directed , M&L For Precast Cement Concrete 1:3:6 Type C1 Using 20 Mm Graded Aggregate Block Solid Building Blocks Or Slabs In Not Exc 10Cm Thick (With Plain Or Interlocking Joints As Directed ) Complete Set In Cm 1:4 , Demolition Of Reinforced Cement Concrete Of Any Description And In Any Position Not Otherwise Specifically Provided For, Complete All As Directed. , M&L Mild Steel Tmt Bars 10 Mm Dia., And Over Cut To Length, Bent To Shape Required, Including Cranking, Bending Spirally For Hooping For Columns, Hooking Ends And Binding With Mild Steel Wire (Annealed) Not Less Than 0.9 Mm Dia., Or Securing With Clips. Complete All As Specified And Directed , Material And Labour For Form Work To Slabs, Chajja With Fair Finish Surfaces Complete All As Specified And Directed. , Material And Labour For Reinforced Cement Concrete Nominal Mix 1:2:4 (Using 20 Mm Graded Crushed Stone Aggregate) Type B1 In Cm 1:6 As In Chajjas, Slabs Work Including Removing Rubbish Off The Premises Complete All As Specified And Directed. , Taking Down Chowkats Or Frames With Shutters (Without Taking Off Shutters From The Frames) Area Exceeding 1.50 Sqm But Not Exc 4 Sqm, Complete All As Directed. , Taking Down Shutters Of Any Description Not Exc1.00 Sqm Each,Complete Al As Directed. , S & F Mild Steel Bands, Straps, Clamps, Hold Fasts, Wall Ties And Similar Articles Conforming To Fe-290-O, Complete All As Specified And Directed. , S & F 2Nd Class Hard Wood Plain Solid Straight Chowkats And Frames, Wrought, Framed Rebated On The Solid Rounded Or Chamfered, Put Together With Glue Pinned At Joints Complete All As Specified And Directed , S&F 35 Mm Thick Second Class Hard Wood Plain Framed, Panelled Shutter (Two Panel) With Lock Rail And Panel Of 9 M Bwp Commercial Ply Or 12 Mm Veneered Particle Board With Commercial Veneering On Both Faces. The Size Of Rails And Stiles As Per Is 1003 ( Part I) Kiln Seasoned And Chemically Pressure Treated Complete All As Specified And Directed , S&F 30 Mm Thick Second Class Hard Wood Glazed And Skelton Shuters , Open Rebated And Prepared To Receive Galss , Gauze , Etc, Divided Into Squares, With Plain , Chamfered Or Rounded Fitted With Cut And Mitred And Rebated Shash Bars Any Numbers Beads For Securing Glass, Etc Sizes Of Members Of Shutters As Speified In Ssr Part I Section 8 , Clause 8.24, Complete All As Specified And Directed. , S&F 30Mm Flush Shutters, Solid Core Construction With Particle Board Core And Plywood Face Panels, Commercial Type On Both Side And Both Face Is Covered With Decorative Face Veneer With Lipping/Frame Tp Match All As Completed And Specified As Directed. , S & F For 18Mm Veneered Decorative Plywood, Grade 1 (With Bwr Resin) With Decorative Face Veneers On Both Faces; Fixed With Screws To Timber Frame Work As In Shutters For Kitchen Cabinate/Cupboard Shutters Etc Complete All As Specified And Directed, , S&F Solid Pvc Door Frame Of Size 50Mm X 47Mm Made Out Of 5Mm Plain Colour Pvc Sheet Reinforced With M.S Square Tube, Supplying And Fixing In Opening As Per Specification And Drawing Complete All As Specified And Directed. , S & F Factory Made Solid Panel Pvc Door Shutter 30 Mm Thick (Style) Consisting Of Frame Made Out Of Ms Tubes For Top & Bottom Rails. Ms Frame Shall Be Covered With Heat Moulded Plain Colour Pvc C Channel Having A Pvc Sheet Strip Of 20Mm Width Stuck Inside With Solvent Cement For Stiles And Plain Colour Pvc Sheets For Top Rail, Lock & Bottom Rail On Either Side & As Gap Insert For Top Rail & Bottom Rail, Panelling Of Plain Colour Pvc Sheet To Be Fitted In The Ms Frame Welded/Sealed To The Stiles & Rails With Suitable Pvc Sheet Beading And Joined Together With Solvent Cement Supplying & Fixing In The Frame At Site As Per Specification & Drawing Complete All As Specified And Directed. , S & F 100Mm Size Mild Steel Butt Hinges Medium Weight Cold Rolled And Fixed. , S& F Aluminium Anodised Barrel Tower Bolts 150Mm Long Of Extruded Section And Fixed , S & F 150Mm Size Extruded Aluminium Alloy Handles, Fabricated Type Anodised , S&F Pre Coated Mild Steel Floor Door Stopper ,Tongue Anodized 140Mm Length Including Vulcanised Rubber Piece , Supply And Fix In Repair Toilet Paper Holder Supar Of Brass Chromium Plated Fitted To Wall With Cp/ Brass Screws Of Make - Sona (Code Al 1001 ) Complete All As Specified And Directed , S&F In Repair Harrison Rails( Curtain Rail), Mild Steel,Chromium Plated With Fixing Brackets,Stops,Rollers Etc, Complete All As Sspecified And Directed. , S & F Aluminium Alloy, Anodised, Sliding Door Bolts 250 Mm Size With Hasp, Staple (Bolt Type) And Fixing Clips Of Sheets, Cast Or Extruded Sections And Fixing Bolts And Sliding Bolts Of Extruded Section Or Cast Aluminium Alloy Complete All As Specified And Directed. , Hacking Out Old Broken Glass (Any Thickness, Size Quality Or Description) From Metal Frame Including Punching Or Drilling Out Old Glazing Pins/Spring Clips And Providing And Fixing New Ones. , S & F Sheet Glass 3Mm Thick Ordinary Quality And Glazing With Oil Putty/Glazing Clips/Beadings In Squares N Exc 0.50 Sqm In Each Pane. , S & F 3Mm Thick Figured Glass, Pin Head Glazing With Oil Putty/Glazing Clips/Beading In Squares N Exc 0.50 Sqm In Each Pane, Complete All As Specified And Directed. , S&F For 50Mm Dia, Polished, Hard Wood Knobs Fixed With Screws, Complete All As Specified And Directed. , S&F For Continuous (Piano) Hinges, Mild Steel, Bright Finish Or Electro Galvanised, 30 Mm Wide Flap (When Open), Complete All As Specified. , S&F In Repair For Continuous (Piano) Hinges, Mild Steel, Bright Finish Or Electro Galvanised, 30 Mm Wide Flap (When Open), Fixed In Repairs, Complete All As Specified. , Supply And Fixed In Repair 15Mm Angle Valves, Cast Copper Alloy Chromium Plated(Fancy Type), Screwed Down, High Pressure, With Crutch Or Butterfly Handle, Screwed Both Ends For Iron Pipe Or For Unions And Fixed, Complete All As Specified And Directed. , S & F 75Mm Size Mild Steel Butt Hinges Medium Weight Cold Rolled And Fixed. , S & F 100Mm Size Extruded Aluminium Alloy Handles, Fabricated Type Anodised , S&F For 100 Mm Size Hasp And Staple, Safety Type, Aluminium Anodized With Mild Steel Hinge Pin Including Bolt To Hinge Plate And Fixed With Screws, Complete All As Specified. , S & F In Repair Vitreous China Wash Down Water Closet Pan Of Pedestal Pattern, White With P Or S Traps, Including Connecting To Trap And To Flushing Pipe Etc Complete All As Specified. , Dismantling Of Pvc(Swr),In Any Position And In Any Description Pattern Including All Fittings Etc Complete All As Specified And Directed. , Supply And Fix In Repairs Pvc (Swr) Wc Connector 110Mm Dia With Lip Ring With Rubber Ring Joints Fixed To Walls Complete All As Specified And Directed. , Supply And Fix 110Mm Bore Pvc (Swr) Pipes Single Socketed In Any Length With Rubber Ring Joints Fixed To Wall Complete All As Specified And Directed. , Supply And Fix 75Mm Bore Pvc (Swr) Pipes Single Socketed In Any Length With Rubber Ring Joints Fixed To Wall Complete All As Specified And Directed. , Supply And Fix 110Mm Bore Pvc (Swr) Bends Any Radius With Access Door Complete All As Specified And Directed. , Supply And Fix 110Mm Bore Pvc (Swr) Junction Single , (Single T) Equal Or Unequal With Access Door Complete All As Specified And Directed. , Supply And Fix 75Mm Bore Pvc (Swr) Bends Any Radius With Access Door Complete All As Specified And Directed. , Supply And Fix 110Mm Bore Pvc (Swr) Vent Cowl Complete All As Specified And Directed. , S&F In Rep Pvc (Swr) Floor Trap, 75Mm Dia Outlet, Plain With Grating Incl Jointing With Solvent Cement, Complete All As Specified And Directed. , Supply And Fix In Rep 15Mm Bore Galvanised Iron Tube, Medium Grade, With All New Fittings, Fixed To Walls And Ceiling Or Laid In Floor Complete All As Specified And Directed. , Supply And Fix In Rep 20Mm Bore Galvanised Iron Tube, Medium Grade, With All New Fittings, Fixed To Walls And Ceiling Or Laid In Floor Complete All As Specified And Directed. , S&F In Repair 15Mm Brass Cp Wall Mixer For Mixing Hot And Cold Water Screwed Down For Iron Pipe And Fixed In Bath Shower,Wash Basin & Kichen Sink With Complete All As Specified And Directed. , Supply And Fix In Repairs Plate Rack Made Of Stainless Steel 0.50Mm Thick,Over All Size 762Mm(H)X787mm(W)X254mm(D) Complete All As Specified And Directed. , S & F In Repairs Chromium Plated Fancy Type 15Mm Dia Stop Cock, Cast Copper Alloy With Crutch Or Butterfly Handle, Screwed Down For Iron Pipe Or For Brass Ferrule Complete All As Specifed. , S & F In Repairs Chromium Plated Fancy Type 15Mm Dia Bib Tap, Cast Copper Alloy With Crutch Or Butterfly Handle, Screwed Down For Iron Pipe Or For Brass Ferrule Complete All As Specifed. , S & F In Repairs Chromium Plated Fancy Type Pillar Taps 15Mm Dia Cast Copper Alloy With Capstan Heads, Screwed Down High Pressure, With Lettered Hot Or Cold With Long Screwed Shanks And Fly Nuts, Screwed For Iron Pipe And Fixed, Complete All As Specified And Directed , S&F In Repairs Vitreous China Wash Hand Basin White Flat Back Of Size 550Mmx400 Mm Including Cutting For And Pinning In End Of Brackets,32 Mm Waste Fittings,Brass Chromium Plated For Glazed Ware Sinks,Basins Etc.With Long Screwed Shanks And Fly Nuts Flange End Bedded In Red Lead Cement And Other End Fixed.And Flush Pipe Of Polytethylene Of Low Or High Density Or Pvc 32 Mm Dia Complete All As Specified And Directed , S & F In Repairs 10 Ltrs Capacity Pvc Valveless Syphonic Action Type Flushing Cistern Low Level White With Inlet Ball Valve, Float, Chain And Pull And Brackets Etc Complete All As Specified And Directed , S & F In Repair Pvc Connection 15Mm Dia 450 Mm Long With Brass Check Nuts And Washers Complete All As Specified And Directed , S & F In Repair Plastic Water Closet Seat Cover, White Closed Pattern With Flat Bottom, And Cover And Mild Steel Chromium Plated Or Aluminised Hinging Device Complete All As Specified And Directed , S&F In Repair For Health Faucet (Abs Body) Mild Steel Chromium Plated Suitable For 15 Mm Dia Pipe With 1.25 Metre Long Flexible Tube And Abs Wall Hook Including Making Connections And Fixed In Position Complete In All Respect As Specified , S&F In Repair Cp Towel Ring Of Ptmt Fixed With Chromium Plated Brass Screws (Min Wt 90 Gms) , S&F In Repair Soap Dish, Any Type, Fiexd To Plugs With Chromium Plated Brass Screws Complete All As Specified And Directed , S&F In Repair Cp Towel Rail 450Mm Long Of Ptmt Fixed With Chromium Plated Brass Screws (Min Wt 190 Gms) Complete All As Specified And Directed , Supply And Fix In Repairs, Stainless Steel Wire Cloth, 0.36Mm Nominal Dia Of Wire And Average Width Of Aperture 1.40Mm And Fixed To Steel Frames With Tinned Tacks, Or Galvanized Wire Staples, Or Fixed To Wooden Frames With First Class Hard Wood Bead, Complete All As Specified And Directed. , M&L Welding In Repairs Exc 2.5 Cm But N.Exceeding 2.5Cm In Length (Thickness Of Metal To Be Welded Not Exceeding 6Mm) Including Cleaning Preparing The Surface And Holding The Members In True Position For Maintenance Of Steel Items Such As Gates, Grills, Doors, Windows Etc., Complete All As Specified And As Directed. , Supply And Fix, Clolthes Hook/Hangers Stainless Steel Set Of Five Casted On Strip, Complete All As Specified And Directed. , S &F In Repairs 15Mm Swivel Shower Of Ptmt Any Colour (Minimum Weigth-40Gms) Including 15Mm Shower Arm, 195Mm Long With Bend Of 45 Degree With Flange Of Ptmt Any Colour (Minimum Weight 40Gm) Complete All As Specified And Directed. , Supply And Fixing In Repair Sheet Glass Shelf Assembly Consisting Of 5.5Mm Thick Sheet Glass Shelf 12Cm Wide With Chromium Plated Bracket Guard And Railing 60Cm Long, Complete All As Specified And Directed. , S&F In Repairs Of Single Piece European Water Closet White Colour With Soft Seat Cover, 5D Powerful Syphonic Flushing System And Rimless Bowl, Size 67X36x74.5 Cm Complete All As Specified And Directed , S&F In Repair Looking Mirror 600 Mm X 450 Mm Beveled Edge Mirror Of Selected Quality Glass Mounted On 6 Mm Thick Commercial Plywood And Fixed To Wooden Plugs With Steel Screws In Repairs, Complete All As Specified. , S& F For Cabinet Mirror With Plastic / Abs Body With Selve Complete All As Specified And Directed , S & F In Repairs Stainless Steel Sinks With Drainage Board Made Out Of 1.00 Mm Thick Sheet For Kitchen With Plugs, Washers, Waste Pipes, Including Bedding In Cement Mortar To Dwarf Wall Or Including Fixing Cast Iron Cantilever Brackets And Connecting Union To Pipe Overall Size 915 Mm X 460 Mm With Bowl Size 410Mm X 330Mm X 160Mm, With And Including Pvc Waste Pipe And Cp Waste Coupling 32 Mm Dia And Making Good To Disturbed Surfaces, Complete All As Specified. , S&F In Repairs Sinks Made Of Stainless Steel Lmm Thick Kitchen Or Laboratory With Plugs, Washers And Wastes; Including Bedding In Cement Mortar On To Dwarf Wall Or Including Fixing Cantilever Brackets And Connecting Union To Pipe, Overall Size 495Mm X 420Mm Bowl Size 410Mm X 330Mm X 160Mm, Including Pvc Waste Pipe And Cp Waste Coupling 32 Mm Dia And Making Good To Disturbed Surfaces, Complete All As Specified And Directed. , S&F In Repair 20Mm Ball Valves High Pressure Of Ptmt With Epoxy Coated Aluminium Rod & Highdensity Plastic Ball Screwed For Iron Pipe And Fixed. (Minimum Weight - 20Mm-210Gm)
Contract Date: Jun 17, 2026 Contract Value : 41.47 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 6
Arunachal Pradesh View Result →
24.
Public Administrative Department #11300743 AOC
Tender For Lac-Ads-Lac Ads 2025-26 Sri. T P Ramakrishnan Mla - Tm Balakurupp Grandhalayam Manava(Avala) Cheruvannur Pt-Perambra Constituency-General Civil Work- 1 Building cocstruction 2 2.32:Clearing grass and removal of the rubbish up to a distance of 50 m outside the periphery of the area cleared. 3 2.8.1:Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil 4 51.2.3:Filling with Quarry Muck
Filling up low lying and water logged areas with local material/ quarry muck, spreading in layers, leveling the top at site and consolidation by ramming, etc complete for improving the CBR value of subgrade 5 4.1.8:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) 6 5.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete 7 5.9.5:Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers 8 5.1.2:Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size derived from natural sources) 9 5.9.6:Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts 10 5.2.2:Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up tot floor five level excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3( 1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size derived from natural sources) 11 50.6.7.1:Laterate masonry with neatly dressed laterate stone of size 40x20x15cm or nearest size in cement mortar 1:6 for foundation and basement including all cost of materials, labour charges etc. 12 2.25:Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. 13 5.9.16.1:Centering and shuttering including strutting, etc. and removal of form for:Edges of slabs and breaks in floors and wallsUnder 20 cm wide 14 5.9.3:Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform 15 5.9.7:Centering and shuttering including strutting, etc. and removal of form for:Stairs, (excluding landings ) except spiral - staircases) 16 5.9.19:Centering and shuttering including strutting, etc. and removal of form for:Weather shade, Chajjas, corbels etc., including edges 17 5.3:Reinforced cement concrete work in beams, suspended floors, roofs, having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (Zone III) derived from natural sources: 3 graded stone aggregate 20 mm nominal size derived from natural sources). 18 5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more 19 5.22A.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo - Mechanically Treated bars of grade Fe-500D or more 20 50.6.7.2:Laterate masonry with neatly dressed laterate stone of size 40x20x15cm or nearest size in cement mortar 1:6 for super structure above plinth level up to floor two level including all cost of materials, labour charges etc. 21 OD410732/2025-2026:Supplying fabricating PVC door with frame in locally available best quality including cost of all fittings, labour charges etc.complete. 22 50.6.1.8:Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x15cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level with thickness 15cm in: CM 1:6 ( 1 cement : 6 coarse sand etc complete 23 13.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) 24 13.16.1:6 mm cement plaster of mix:1:3 ( 1 cement : 3 fine sand) 25 13.43.1:Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer 26 13.44.1:Finishing walls with water proofing cement paint of required shade:New work (Two or more coats applied @ 3.84 kg/10 sqm) 27 13.61.1:Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work 28 10.25.2:Item Shifted to Sub head 14 as item 14.73Item Shifted to head 14 as item 14.74Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works 29 21.1.1.2:Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately):For fixed portionPowder coated aluminium (minimum thickness of powder coating 50 micron) 30 21.1.2.2:For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately)Powder coated aluminium (minimum thickness of powder coating 50 micron) 31 21.3.1:Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness (weight not less than 10kg/sqm) 32 8.31:Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in- Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 33 11.37:Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete 34 17.7.4:Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tap 35 50.17.1.5:Supplying and fixing CP Health Faucet superior quality ( Jagur or equvalent make ) including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge. 36 17.1.1:Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm Sand Cast Iron P or S trap, 10 litter low level white P.V.C.flushing cistern, including flush pipe, manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever require:White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests 37 17.2.1:Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:W.C. pan with ISI marked white solid plastic seat and lid 38 18.48:Providing and placing on terrace (at all floor levels) polyethylene water storage tank :ISI 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 39 51.19.ST2:Supplying and installing ready made PVC Septic tank including the cost of carriage, trenching, placing at the level below ground level as specified as per the direction of engineer in charge (Provision for CC/RCC/Sand/06mm aggregate for the preparation of bed shall be paid separately)
2. 15 to below 25 flush capacity 40 50.18.9.13.2:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 25 mm dia 10 Kgf/cm2- External work - Exposed on wall 41 50.18.9.14.1:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 32 mm dia 10 Kgf/cm2 - External work- Exposed on wall 42 50.18.9.7.2:Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.63 mm dia 4 Kgf/cm2 43 50.18.9.9.2:Providing and fixing PVC pipes includes joints of pipes with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in CHarge. 110 mm dia 4 Kg/cm2 44 50.18.9.20.7:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 63 mm dia vent cowl 45 50.18.9.22.8:Providing and fixing PVC moulded fittings /accessories for Rigid PVC pipes, including jointing with PVC solvent cement -110 mm dia Vent cowl 46 50.18.9.20.1:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 63 mm dia Elbow 47 50.18.9.20.3:Providing and fixing PVC moulded fittings /accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 63 mm dia Door Elbow 48 50.18.9.20.4:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 63 mm dia Bend 49 50.18.9.22.1:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110 mm dia Elbow 50 50.18.9.22.3:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement-110 mm dia Door Elbow 51 50.18.9.22.4:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement- 110 mm dia Bend 52 50.17.1.1:Supplying and fixing Stainless steel soap dish including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge. 53 50.17.1.2:Supplying and fixing CP Towel rod 45cm or nearest available length including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge. 54 18.15.1:Providing and fixing brass bib cock of approved quality :15 mm nominal bore 55 18.58.1.1:Providing and fixing PTMT grating of approved quality and colour.Circular type100 mm nominal dia Please Enable Macros to View BoQ information
Contract Date: Jun 17, 2026 Contract Value : 24.12 Lakh
Government Departments No of Bidders 2
25.
Public Administrative Department #11300257 AOC
Tender For Annual Plan-Various Government Schools Maintenance-155/2024-25-General Civil Work - Various Govt. School maintenance 2 15.3:Demolishing R.C.C. work manually / by mechanical means including stacking of steel bars and disposal of unserviceable material with in 50 metres lead as per direction of Engineer -in-Charge. 3 15.7.4:Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge.In cement mortar 4 15.9.2:Demolishing stone rubble masonry manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer -in- Charges:In cement mortar 5 2.8.1:Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil 6 4.1.8:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) 7 OD522947/2024-2025: DRY RUBBLE MASONRY _ Dry rubble without concrete levelling course masonry with good quality blasted rubble including packing to compactness to lines and levels cost and conveyance of all materials labour charges etc. complete as per direction of Departmental officers at site 8 7.1.1:Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand) 9 2.25:Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. 10 50.6.2.2:Solid masonry using pre cast solid blocks (factory made) of size 30x20x15cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level with thickness 15cm in : CM 1:6 ( 1 cement : 6 coarse sand) etc complete 11 5.9.5:Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers 12 5.9.3:Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform 13 5.1.2:Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size derived from natural sources) 14 5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more 15 5.3:Reinforced cement concrete work in beams, suspended floors, roofs, having slope up to 15°landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (Zone III)derived from natural sources: 3 graded stone aggregate 20 mm nominal sizederived from natural sources). 16 5.9.16.1:Centering and shuttering including strutting, etc. and removal of form for:Edges of slabs and breaks in floors and wallsUnder 20 cm wide 17 10.25.2:Item Shifted to Sub head 14 as item 14.73Item Shifted to head 14 as item 14.74Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works 18 10.30.1:Providing & fixing glass panes with putty andglazing clips in steel doors, windows, clerestory windows all complete with :4.0 mm thick glass panes 19 13.16.1:6 mm cement plaster of mix:1:3 ( 1 cement : 3 fine sand) 20 13.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) 21 11.36:Providing and fixing I st quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer -in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 22 11.38:Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of Ist quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 ( 1 cement : 4 Coarse sand), including pointing the joints with white cement and matching pigments etc., complete. 23 9.121:Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross- section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminated shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2 mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame. 24 9.122.1:Providing and fixing to existing door frames.30 mm thick Glas Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS : 14856, including fixing to frames. 25 17.1.1:Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm Sand Cast Iron P or S trap, 10 litter low level white P.V.C.flushing cistern, including flush pipe, manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever require:White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests 26 17.2.1:Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:W.C. pan with ISI marked white solid plastic seat and lid 27 13.43.1:Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer 28 13.60.1:Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Two or more coats on new work 29 13.61.1:Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work 30 50.17.1.4:Supplying and fixing CP Health faucet good quality including cost of materials and labour charges etc. complete as per the direction of site engineer-in-charge. 31 50.18.7.2.1:Providing and fixing PVC pipes, fittings including fixing the pipe with claps at 1.00 metre spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 20 mm dia 12Kgf/cm2 - Internal work - Exposed on wall 32 50.18.7.4.1:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 32 mm dia 10Kgf/cm2- Internal work - Exposed on wall 33 50.18.9.17.2:Providing and fixing PVC pipes including fixing the pipe with clamps/clips at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 63 mm dia 4 Kgf/cm2- External work - exposed on wall 34 50.18.9.20.2:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement -63 dia 45 degree Elbow 35 50.18.9.20.7:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 63 mm dia vent cowl 36 50.18.9.9.2:Providing and fixing PVC pipes includes joints of pipes with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in CHarge. 110 mm dia 4 Kg/cm2 37 15.13.1:Taking out doors, windows and clerestory window shutters (steel or wood ) including stacking within 50 metres lead:Of area 3 sq. metres and below 38 14.53.1:Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade:One or more coats on old work 39 15.56:Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. 40 14.54.1:Painting with synthetic enamel paint of approved brand and manufacture of required colour to an give even shade:One or more coats on old work
Contract Date: Jun 16, 2026 Contract Value : 8.47 Lakh
Government Departments No of Bidders 2
26.
Public Administrative Department #11300148 AOC
Tender For Construction Of Inspection Banglow, Guest House, Boundary Wall & Garage Near Suklai Head Works Under Extension, Renovation And Modernization Of (Erm), Sukla Irrigation Project Under Pmksy-Aibp For The Year 2021-22. , Construction Of Inspection Banglow, Guest House (Ground Floor). Earth Work : Earth Work In Excavation By Mechanical Means (Hydraulic Excavator) /Manual Means In Foundation Trenches Or Drains (Not Exceeding 1.5 M In Width Or 10 Sqm On Plan), Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soil As Directed, Within A Lead Of 50 M. All Kinds Of Soil. , Excavating, Supplying And Filling Of Local Earth (Including Royalty) By Mechanical Transport Upto A Lead Of 5Km Also Including Ramming And Watering Of The Earth In Layers Not Exceeding 20 Cm In Trenches, Plinth, Sides Of Foundation Etc. Complete. , Steel Work : Steel Reinforcement For Reinforced Cement Concrete Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Upto Plinth Level. Thermo-Mechanically Treated Bars Of Grade Fe-500D Or More , Steel Reinforcement For Reinforced Cement Concrete Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Above Plinth Level. Thermo-Mechanically Treated Bars Of Grade Fe-500D Or More , Cement Concrete Work : Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level : 1:2:4 (1 Cement : 2 Coarse Sand (Zone-Iii) Derived From Natural Sources : 4 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources) , Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level : 1:2:4 (1 Cement : 2 Coarse Sand (Zone-Iii) Derived From Natural Sources : 4 Graded Stone Aggregate 40 Mm Nominal Size Derived From Natural Sources , Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement - All Work Up To Plinth Level : 1:1.5:3 (1 Cement : 1.5 Coarse Sand (Zone-Iii) Derived From Natural Sources : 3 Graded Stone Aggregate 20 Mm Nominal Size De Rived From Natural Sources) , Reinforced Cement Concrete Work In Walls (Any Thickness), Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc. Above Plinth Level Up To Floor Five Level, Excluding Cost Of Centering, Shuttering, Finishing And Reinforcement : And Struts Etc. Above Plinth Level Up To Floor Five Level, Excluding Cost Of Centering, Shuttering, Finishing And Reinforcement : 1:1.5:3 (1 Cement : 1.5 Coarse Sand(Zone-Iii) Derived From Natural Sources : 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources) , Reinforced Cement Concrete Work In Beams, Suspended Floors, Roofs Having Slope Up To 15° Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Window Sills, Staircases And Spiral Stair Cases Above Plinth Level Up To Floor Five Level, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement With 1:1.5:3 (1 Cement : 1.5 Coarse Sand(Zone-Iii) Derived From Natural Sources : 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources). , Providing And Laying Damp-Proof Course 40Mm Thick With Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand (Zone-Iii) Derived From Natural Sources : 4 Graded Stone Aggregate 12.5Mm Nominal Size Derived From Natural Sources) , Shuttering & Formwork : Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For Foundations, Footings, Bases Of Columns, Etc. For Mass Concrete , Lintels, Beams, Plinth Beams, Girders, Bressumers And Cantilevers , Columns, Pillars, Piers, Abutments, Posts And Struts , Suspended Floors, Roofs, Landings, Balconies And Access Platform , Stairs, (Excluding Landings) Except Spiral-Staircases , Pre Construction Anti - Termite Treatment : Diluting And Injecting Chemical Emulsion For Post-Constructional Anti-Termite Treatment (Excluding The Cost Of Chemical Emulsion) : Treatment Of Soil Under Existing Floors Using Chemical Emulsion @ One Litre Per Hole, 300 Mm Apart Including Drilling 12 Mm Diameter Holes And Plugging With Cement Mortar 1 :2 (1 Cement : 2 Coarse Sand) To Match The Existing Floor: With Chlorpyriphos/Lindane E.C. 20% With 1% Concentration , Brick Work : Dry Brick Pitching Half Brick Thick In Drains Including Supply Of Bricks And Preparing The Surface Complete : With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 , Brick Work With Common Burnt Clay Modular Bricks Of Class Designation 7.5 In Foundation And Plinth In: Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) , Half Brick Masonry With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 In Superstructure Above Plinth Level Up To Floor V Level. Cement Mortar 1:4 (1 Cement :4 Coarse Sand) , Wood Work : Providing Wood Work In Frames Of Doors, Windows, Clerestory Windows And Other Frames, Wrought Framed And Fixed In Position With Hold Fast Lugs Or With Dash Fasteners Of Required Dia & Length (Hold Fast Lugs Or Dash Fastener Shall Be Paid For Separately). Sal Wood , Providing And Fixing Panelled Or Panelled And Glazed Shutters For Doors, Windows And Clerestory Windows, Fixing With Butt Hinges Of Required Size With Necessary Screws, Excluding Panelling Which Will Be Paid For Separately, All Complete As Per Direction Of Engineer-In-Charge. (Note:- Butt Hinges And Necessary Screws Shall Be Paid Separately) Second Class Teak Wood 35 Mm Thick Shutters , Pvc Door Frame : Providing And Fixing Factory Made Pvc Door Frame Made Of Pvc Extruded Sections Of Size 75 Mm X 53 Mm, Having Wall Thickness 2.0 Mm (± 0.2 Mm). Both Verticalssides Of The Frame Reinforced With Pvc Profile Of Cross Section Size 28 Mm X 30 Mm X 2 Mm Thickness (± 0.2 Mm) And 75 Mm X 200 Mm Long, Including Reinforcing Both Ends Of The Top Frame With Pvc Profile. Pvc Door Frame And Pvc Reinforcement Profile To Be Mitred Cut, Jointed And Fusion Welded Together, Including Providing And Fixing 3 Nos Of 125 Mm Long Stainless Steel Hinges To Frame, Fixing The Frame With Jamb With Required Nos & Sizes Of Anchor Dash Fastener, All Complete As Per Manufacturers Specification And Direction Of Engineerin-Charge. , Providing And Fixing 37 Mm Thick Factory Made Pvc Door Shutter, Styles And Rails Made Of Pvc Hollow Section Of Size 100 Mm X 37 Mm With Wall Thickness 2 Mm (± 0.2 Mm), With Inbuilt Bead On One Side, Styles And Rails Mitered Cut And Joint At The Corners By Means Of 2 Nos Of Plastic Brackets Of Size 75 Mm X 220 Mm At Each Corner And Stainless Steel Screws, Reinforcing The Hinge Side Of Tyle By Inserting Pvc Profile Of Size 28 Mm X 30 Mm, With Wall Thickness 2 Mm ( ± 0.2 Mm). Lockrail Of Size 100 Mm X 37 Mm, Wall Thickness 2 Mm (+ 0.2 Mm) Will Be Fixed To The Vertical Styles. Providing With Pvc Snapfit Beads And Panel Of Size 100 Mm X 20 Mm, And Inserting 2 Nos Tie Bar Of 6 Mm Dia And Fastening With Nuts And Washers Complete, All As Per Manufacturers Specification And Direction Of Engineer-In-Charge. , Providing And Fixing In Position Collapsible Steel Shutters With Vertical Channels 20X10x2 Mm And Braced With Flat Iron Diagonals 20X5 Mm Size, With Top And Bottom Rail Of T-Iron 40X40x6 Mm, With 40 Mm Dia Steel Pulleys, Complete With Bolts, Nuts, Locking Arrangement, Stoppers, Handles, Including Applying A Priming Coat Of Approved Steel Primer. , Providing And Fixing Aluminium Work For Doors, Windows, Ventilators And Partitions With Extruded Built Up Standard Tubular Sections/ Appropriate Z Sections And Other Sections Of Approved Make Conforming To Is: 733 And Is: 1285, Fixing With Dash Fasteners Of Required Dia And Size, Including Necessary Filling Up The Gaps At Junctions, I.E. At Top, Bottom And Sides With Required Epdm Rubber/ Neoprene Gasket Etc. Aluminium Sections Shall Be Smooth, Rust Free, Straight, Mitred And Jointed Mechanically Wherever Required Including Cleat Angle, Aluminium Snap Beading For Glazing / Paneling, C.P. Brass / Stainless Steel Screws, All Complete As Per Architectural Drawings And The Directions Of Engineer-In-Charge. (Glazing, Paneling And Dash Fasteners To Be Paid For Separately) : For Fixed Portion Less Than 12.50 Kg/Sqm) Anodised Aluminium (Anodised Transparent Or Dyed To Required Shade According To Is: 1868, Minimum Anodic Coating Of Grade Ac 15) , For Shutters Of Doors, Windows & Ventilators Including Providing And Fixing Hinges/ Pivots And Making Provision For Fixing Of Fittings Wherever Required Including The Cost Of Epdm Rubber / Neoprene Gasket Required (Fittings Shall Be Paid For Separately) Powder Coated Aluminium (Minimum Thickness Of Powder Coating 50 Micron) , Providing And Fixing Glazing In Aluminium Door, Window, Ventilator Shutters And Partitions Etc. With Epdm Rubber / Neoprene Gasket Etc. Complete As Per The Architectural Drawings And The Directions Of Engineer-In-Charge . (Cost Of Aluminium Snap Beading Shall Be Paid In Basic Item): With Float Glass Panes Of 5 Mm Thickness (Weight Not Less Than 12.50 Kg/Sqm) , Tiles Works : Providing And Laying Vitrified Floor Tiles In Different Sizes (Thickness To Be Specified By The Manufacturer) With Water Absorption Less Than 0.08% And Conforming To Is: 15622, Of Approved Make, In All Colours And Shades, Laid On 20Mm Thick Cement Mortar 1:4 (1 Cement : 4 Coarse Sand), Jointing With Grey Cement Slurry @ 3.3 Kg/ Sqm Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete. Size Of Tile 600X600 Mm , Providing And Laying Vitrified Tiles In Different Sizes (Thickness To Be Specified By Manufacturer), With Water Absorption Less Than 0.08 % And Conforming To I.S. 15622, Of Approved Make, In All Colours & Shade, In Skirting, Riser Of Steps, Over 12 Mm Thick Bed Of Cement Mortar 1:3 (1 Cement: 3 Coarse Sand), Jointing With Grey Cement Slurry @ 3.3 Kg/ Sqm Including Grouting The Joint With White Cement & Matching Pigments Etc. Complete. Size Of Tile 600X600 Mm , Providing And Fixing M.S. Grills Of Required Pattern In Frames Of Windows Etc. With M.S. Flats, Square Or Round Bars Etc. Including Priming Coat With Approved Steel Primer All Complete. Fixed To Steel Windows By Welding. , Providing And Fixing Stainless Steel ( Grade 304) Railing Made Of Hollow Tubes, Channels, Plates Etc., Including Welding, Grinding, Buffing, Polishing And Making Curvature (Wherever Required) And Fitting The Same With Necessary Stainless Steel Nuts And Bolts Complete, I/C Fixing The Railing With Necessary Accessories & Stainless Steel Dash Fasteners , Stainless Steel Bolts Etc., Of Required Size, On The Top Of The Floor Or The Side Of Waist Slab With Suitable Arrangement As Per Approval Of Engineer-In Charge, (For Payment Purpose Only Weight Of Stainless Steel Members Shall Be Considered Excluding Fixing Accessories Such As Nuts, Bolts, Fasteners Etc.) , Plastering Works : 12 Mm Cement Plaster On The Rough Side Of Single Or Half Brick Wall Of Mix : 1:4 (1 Cement: 4 Fine Sand) , 15 Mm Cement Plaster On The Rough Side Of Single Or Half Brick Wall Of Mix : 1:4 (1 Cement: 4 Fine Sand) , 20 Mm Cement Plaster Of Mix : 1:4 (1 Cement: 4 Fine Sand) , Plinth Protection : Making Plinth Protection 50Mm Thick Of Cement Concrete 1:3:6 (1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20 Mm Nominal Size) Over 75Mm Thick Bed Of Dry Brick Ballast 40 Mm Nominal Size, Well Rammed And Consolidated And Grouted With Fine Sand, Including Necessary Excavation Leveling And Dressing And Finishing The Top Smooth. , Painting : With Ready Mixed Pink Or Grey Primer Of Approved Brand And Manufacture On Wood Work (Hard And Soft Wood , Painting Wood Work With Deluxe Multi Surface Paint Of Required Shade. Two Or More Coat Applied @ 0.90 Ltr/10 Sqm Over An Under Coat Of Primer Applied @0.75 Ltr/10 Sqm Of Approved Brand And Manufacture , With Ready Mixed Red Oxide Zinc Chromate Primer Of Approved Brand And Manufacture On Steel Galvanised Iron/ Steel Works , Painting Steel Work With Deluxe Multi Surface Paint To Give An Even Shade. Two Or More Coat Applied @ 0.90 Ltr/ 10 Sqm Over An Under Coat Of Primer Applied @ 0.80 Ltr/ 10 Sqm Of Approved Brand And Manufacture , Providing And Applying Plaster Of Paris Putty Of 2 Mm Thickness Over Plastered Surface To Prepare The Surface Even And Smooth Complete. , Applying One Coat Of Water Thinnable Cement Primer Of Approved Brand And Manufacture On Wall Surface : Water Thinnable Cement Primer , Finishing Walls With 100% Premium Acrylic Emulsion Paint Having Voc Less Than 50 Gm/Litre And Uv Resistance As Per Is 15489:2004, Alkali & Fungal Resistance, Dirt Resistance Exterior Paint Of Required Shade (Company Depot Tinted) With Silicon Additives. New Work (Two Or More Coats Applied @ 1.43 Litre/ 10 Sqm. Over And Including Priming Coat Of Exterior Primer Applied @ 0.90 Litre/10 Sqm. , Door Window Fittings : Providing And Fixing Aluminium Sliding Door Bolts, Isi Marked Anodised (Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868), Transparent Or Dyed To Required Colour Or Shade, With Nuts And Screws Etc. Complete : 300Mm X 16Mm , Providing And Fixing Aluminium Tower Bolts, Isi Marked, Anodised (Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868 ) Transparent Or Dyed To Required Colour Or Shade, With Necessary Screws Etc. Complete : 300Mm X 10Mm , Providing And Fixing Aluminium Handles, Isi Marked, Anodised (Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868) Transparent Or Dyed To Required Colour Or Shade, With Necessary Screws Etc. Complete : 125Mm , Providing And Fixing Ptmt Butt Hinges With Necessary Screws Etc. Complete. 75X60x10 Mm Fitted With 5.5 Mm Dia M.S. Bright Bar Rod Weighing Not Less Than 34 Gms , Construction Of Inspection Banglow Cum Guest House (First Floor). Steel Work : Steel Reinforcement For Reinforced Cement Concrete Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Above Plinth Level. Thermo-Mechanically Treated Bars Of Grade Fe-500D Or More , Cement Concrete Work : Reinforced Cement Concrete Work In Walls (Any Thickness), Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc. Above Plinth Level Up To Floor Five Level, Excluding Cost Of Centering, Shuttering, Finishing And Reinforcement : 1:1.5:3 (1 Cement : 1.5 Coarse Sand(Zone-Iii) Derived From Natural Sources : 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources) , Reinforced Cement Concrete Work In Beams, Suspended Floors, Roofs Having Slope Up To 15° Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Window Sills, Staircases And Spiral Stair Cases Above Plinth Level Up To Floor Five Level, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement With 1:1.5:3 (1 Cement : 1.5 Coarse Sand(Zone-Iii) Derived From Natural Sources : 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources). , Shuttering & Formwork : Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For Lintels, Beams, Plinth Beams, Girders, Bressumers And Cantilevers , Columns, Pillars, Piers, Abutments, Posts And Struts , Suspended Floors, Roofs, Landings, Balconies And Access Platform , Stairs, (Excluding Landings) Except Spiral-Staircases , Brick Work : Half Brick Masonry With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 In Superstructure Above Plinth Level Up To Floor V Level. Cement Mortar 1:4 (1 Cement :4 Coarse Sand) , Wood Work : Providing Wood Work In Frames Of Doors, Windows, Clerestory Windows And Other Frames, Wrought Framed And Fixed In Position With Hold Fast Lugs Or With Dash Fasteners Of Required Dia & Length (Hold Fast Lugs Or Dash Fastener Shall Be Paid For Separately). Sal Wood , Providing And Fixing Panelled Or Panelled And Glazed Shutters For Doors, Windows And Clerestory Windows, Fixing With Butt Hinges Of Required Size With Necessary Screws, Excluding Panelling Which Will Be Paid For Separately, All Complete As Per Direction Of Engineer-In-Charge. (Note:- Butt Hinges And Necessary Screws Shall Be Paid Separately) Second Class Teak Wood 35 Mm Thick Shutters , Pvc Door Frame : Providing And Fixing Factory Made Pvc Door Frame Made Of Pvc Extruded Sections Of Size 75 Mm X 53 Mm, Having Wall Thickness 2.0 Mm (± 0.2 Mm). Both Verticalssides Of The Frame Reinforced With Pvc Profile Of Cross Section Size 28 Mm X 30 Mm X 2 Mm Thickness (± 0.2 Mm) And 75 Mm X 200 Mm Long, Including Reinforcing Both Ends Of The Top Frame With Pvc Profile. Pvc Door Frame And Pvc Reinforcement Profile To Be Mitred Cut, Jointed And Fusion Welded Together, Including Providing And Fixing 3 Nos Of 125 Mm Long Stainless Steel Hinges To Frame, Fixing The Frame With Jamb With Required Nos & Sizes Of Anchor Dash Fastener, All Complete As Per Manufacturers Specification And Direction Of Engineerin-Charge. , Providing And Fixing 37 Mm Thick Factory Made Pvc Door Shutter, Styles And Rails Made Of Pvc Hollow Section Of Size 100 Mm X 37 Mm With Wall Thickness 2 Mm (± 0.2 Mm), With Inbuilt Bead On One Side, Styles And Rails Mitered Cut And Joint At The Corners By Means Of 2 Nos Of Plastic Brackets Of Size 75 Mm X 220 Mm At Each Corner And Stainless Steel Screws, Reinforcing The Hinge Side Of Tyle By Inserting Pvc Profile Of Size 28 Mm X 30 Mm, With Wall Thickness 2 Mm ( ± 0.2 Mm). Lockrail Of Size 100 Mm X 37 Mm, Wall Thickness 2 Mm (+ 0.2 Mm) Will Be Fixed To The Vertical Styles. Providing With Pvc Snapfit Beads And Panel Of Size 100 Mm X 20 Mm, And Inserting 2 Nos Tie Bar Of 6 Mm Dia And Fastening With Nuts And Washers Complete, All As Per Manufacturers Specification And Direction Of Engineer-In-Charge. , Providing And Fixing Aluminium Work For Doors, Windows, Ventilators And Partitions With Extruded Built Up Standard Tubular Sections/ Appropriate Z Sections And Other Sections Of Approved Make Conforming To Is: 733 And Is: 1285, Fixing With Dash Fasteners Of Required Dia And Size, Including Necessary Filling Up The Gaps At Junctions, I.E. At Top, Bottom And Sides With Required Epdm Rubber/ Neoprene Gasket Etc. Aluminium Sections Shall Be Smooth, Rust Free, Straight, Mitred And Jointed Mechanically Wherever Required Including Cleat Angle, Aluminium Snap Beading For Glazing / Paneling, C.P. Brass / Stainless Steel Screws, All Complete As Per Architectural Drawings And The Directions Of Engineer-In-Charge. (Glazing, Paneling And Dash Fasteners To Be Paid For Separately) : Rust Free, Straight, Mitred And Jointed Mechanically Wherever Required Including Cleat Angle, Aluminium Snap Beading For Glazing / Paneling, C.P. Brass / Stainless Steel Screws, All Complete As Per Architectural Drawings And The Directions Of Engineer-In-Charge. (Glazing, Paneling And Dash Fasteners To Be Paid For Separately) : For Fixed Portion Less Than 12.50 Kg/Sqm) Anodised Aluminium (Anodised Transparent Or Dyed To Required Shade According To Is: 1868, Minimum Anodic Coating Of Grade Ac 15) , For Shutters Of Doors, Windows & Ventilators Including Providing And Fixing Hinges/ Pivots And Making Provision For Fixing Of Fittings Wherever Required Including The Cost Of Epdm Rubber / Neoprene Gasket Required (Fittings Shall Be Paid For Separately) Powder Coated Aluminium (Minimum Thickness Of Powder Coating 50 Micron) , Providing And Fixing Glazing In Aluminium Door, Window, Ventilator Shutters And Partitions Etc. With Epdm Rubber / Neoprene Gasket Etc. Complete As Per The Architectural Drawings And The Directions Of Engineer-In-Charge . (Cost Of Aluminium Snap Beading Shall Be Paid In Basic Item): With Float Glass Panes Of 5 Mm Thickness (Weight Not Less Than 12.50 Kg/Sqm) , Tiles Works : Providing And Laying Vitrified Floor Tiles In Different Sizes (Thickness To Be Specified By The Manufacturer) With Water Absorption Less Than 0.08% And Conforming To Is: 15622, Of Approved Make, In All Colours And Shades, Laid On 20Mm Thick Cement Mortar 1:4 (1 Cement : 4 Coarse Sand), Jointing With Grey Cement Slurry @ 3.3 Kg/ Sqm Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete. Size Of Tile 600X600 Mm , Providing And Laying Vitrified Tiles In Different Sizes (Thickness To Be Specified By Manufacturer), With Water Absorption Less Than 0.08 % And Conforming To I.S. 15622, Of Approved Make, In All Colours & Shade, In Skirting, Riser Of Steps, Over 12 Mm Thick Bed Of Cement Mortar 1:3 (1 Cement: 3 Coarse Sand), Jointing With Grey Cement Slurry @ 3.3 Kg/ Sqm Including Grouting The Joint With White Cement & Matching Pigments Etc. Complete. Size Of Tile 600X600 Mm , Providing And Fixing M.S. Grills Of Required Pattern In Frames Of Windows Etc. With M.S. Flats, Square Or Round Bars Etc. Including Priming Coat With Approved Steel Primer All Complete. Fixed To Steel Windows By Welding. , Providing And Fixing Stainless Steel ( Grade 304) Railing Made Of Hollow Tubes, Channels, Plates Etc., Including Welding, Grinding, Buffing, Polishing And Making Curvature (Wherever Required) And Fitting The Same With Necessary Stainless Steel Nuts And Bolts Complete, I/C Fixing The Railing With Necessary Accessories & Stainless Steel Dash Fasteners , Stainless Steel Bolts Etc., Of Required Size, On The Top Of The Floor Or The Side Of Waist Slab With Suitable Arrangement As Per Approval Of Engineer-In Charge, (For Payment Purpose Only Weight Of Stainless Steel Members Shall Be Considered Excluding Fixing Accessories Such As Nuts, Bolts, Fasteners Etc.) , Plastering Works : 12 Mm Cement Plaster On The Rough Side Of Single Or Half Brick Wall Of Mix : 1:4 (1 Cement: 4 Fine Sand) , 15 Mm Cement Plaster On The Rough Side Of Single Or Half Brick Wall Of Mix : 1:4 (1 Cement: 4 Fine Sand) , 20 Mm Cement Plaster Of Mix : 1:4 (1 Cement: 4 Fine Sand) , Painting : With Ready Mixed Pink Or Grey Primer Of Approved Brand And Manufacture On Wood Work (Hard And Soft Wood , Painting Wood Work With Deluxe Multi Surface Paint Of Required Shade. Two Or More Coat Applied @ 0.90 Ltr/10 Sqm Over An Under Coat Of Primer Applied @0.75 Ltr/10 Sqm Of Approved Brand And Manufacture , With Ready Mixed Red Oxide Zinc Chromate Primer Of Approved Brand And Manufacture On Steel Galvanised Iron/ Steel Works , Painting Steel Work With Deluxe Multi Surface Paint To Give An Even Shade. Two Or More Coat Applied @ 0.90 Ltr/ 10 Sqm Over An Under Coat Of Primer Applied @ 0.80 Ltr/ 10 Sqm Of Approved Brand And Manufacture , Providing And Applying Plaster Of Paris Putty Of 2 Mm Thickness Over Plastered Surface To Prepare The Surface Even And Smooth Complete. , Applying One Coat Of Water Thinnable Cement Primer Of Approved Brand And Manufacture On Wall Surface : Water Thinnable Cement Primer , Finishing Walls With 100% Premium Acrylic Emulsion Paint Having Voc Less Than 50 Gm/Litre And Uv Resistance As Per Is 15489:2004, Alkali & Fungal Resistance, Dirt Resistance Exterior Paint Of Required Shade (Company Depot Tinted) With Silicon Additives. New Work (Two Or More Coats Applied @ 1.43 Litre/ 10 Sqm. Over And Including Priming Coat Of Exterior Primer Applied @ 0.90 Litre/10 Sqm. , Door Window Fittings : Providing And Fixing Aluminium Sliding Door Bolts, Isi Marked Anodised (Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868), Transparent Or Dyed To Required Colour Or Shade, With Nuts And Screws Etc. Complete : 300Mm X 16Mm , Providing And Fixing Aluminium Tower Bolts, Isi Marked, Anodised (Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868 ) Transparent Or Dyed To Required Colour Or Shade, With Necessary Screws Etc. Complete : 300Mm X 10Mm , Providing And Fixing Aluminium Handles, Isi Marked, Anodised (Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868) Transparent Or Dyed To Required Colour Or Shade, With Necessary Screws Etc. Complete : 125Mm , Providing And Fixing Ptmt Butt Hinges With Necessary Screws Etc. Complete. 75X60x10 Mm Fitted With 5.5 Mm Dia M.S. Bright Bar Rod Weighing Not Less Than 34 Gms , Construction Of Inspection Banglow, Guest House (Second Floor). Steel Work : Steel Reinforcement For Reinforced Cement Concrete Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Above Plinth Level. Thermo-Mechanically Treated Bars Of Grade Fe-500D Or More , Cement Concrete Work : Reinforced Cement Concrete Work In Walls (Any Thickness), Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc. Above Plinth Level Up To Floor Five Level, Excluding Cost Of Centering, Shuttering, Finishing And Reinforcement : 1:1.5:3 (1 Cement : 1.5 Coarse Sand(Zone-Iii) Derived From Natural Sources : 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources) , Reinforced Cement Concrete Work In Beams, Suspended Floors, Roofs Having Slope Up To 15° Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Window Sills, Staircases And Spiral Stair Cases Above Plinth Level Up To Floor Five Level, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement With 1:1.5:3 (1 Cement : 1.5 Coarse Sand(Zone-Iii) Derived From Natural Sources : 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources). , Shuttering & Formwork : Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For Lintels, Beams, Plinth Beams, Girders, Bressumers And Cantilevers , Columns, Pillars, Piers, Abutments, Posts And Struts , Suspended Floors, Roofs, Landings, Balconies And Access Platform , Stairs, (Excluding Landings) Except Spiral-Staircases , Brick Work : Half Brick Masonry With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 In Superstructure Above Plinth Level Up To Floor V Level. Cement Mortar 1:4 (1 Cement :4 Coarse Sand) , Wood Work : Providing Wood Work In Frames Of Doors, Windows, Clerestory Windows And Other Frames, Wrought Framed And Fixed In Position With Hold Fast Lugs Or With Dash Fasteners Of Required Dia & Length (Hold Fast Lugs Or Dash Fastener Shall Be Paid For Separately). Sal Wood , Providing And Fixing Panelled Or Panelled And Glazed Shutters For Doors, Windows And Clerestory Windows, Fixing With Butt Hinges Of Required Size With Necessary Screws, Excluding Panelling Which Will Be Paid For Separately, All Complete As Per Direction Of Engineer-In-Charge. (Note:- Butt Hinges And Necessary Screws Shall Be Paid Separately) Second Class Teak Wood 35 Mm Thick Shutters , Pvc Door Frame : Providing And Fixing Factory Made Pvc Door Frame Made Of Pvc Extruded Sections Of Size 75 Mm X 53 Mm, Having Wall Thickness 2.0 Mm (± 0.2 Mm). Both Verticalssides Of The Frame Reinforced With Pvc Profile Of Cross Section Size 28 Mm X 30 Mm X 2 Mm Thickness (± 0.2 Mm) And 75 Mm X 200 Mm Long, Including Reinforcing Both Ends Of The Top Frame With Pvc Profile. Pvc Door Frame And Pvc Reinforcement Profile To Be Mitred Cut, Jointed And Fusion Welded Together, Including Providing And Fixing 3 Nos Of 125 Mm Long Stainless Steel Hinges To Frame, Fixing The Frame With Jamb With Required Nos & Sizes Of Anchor Dash Fastener, All Complete As Per Manufacturers Specification And Direction Of Engineerin-Charge. , Providing And Fixing 37 Mm Thick Factory Made Pvc Door Shutter, Styles And Rails Made Of Pvc Hollow Section Of Size 100 Mm X 37 Mm With Wall Thickness 2 Mm (± 0.2 Mm), With Inbuilt Bead On One Side, Styles And Rails Mitered Cut And Joint At The Corners By Means Of 2 Nos Of Plastic Brackets Of Size 75 Mm X 220 Mm At Each Corner And Stainless Steel Screws, Reinforcing The Hinge Side Of Tyle By Inserting Pvc Profile Of Size 28 Mm X 30 Mm, With Wall Thickness 2 Mm ( ± 0.2 Mm). Lockrail Of Size 100 Mm X 37 Mm, Wall Thickness 2 Mm (+ 0.2 Mm) Will Be Fixed To The Vertical Styles. Providing With Pvc Snapfit Beads And Panel Of Size 100 Mm X 20 Mm, And Inserting 2 Nos Tie Bar Of 6 Mm Dia And Fastening With Nuts And Washers Complete, All As Per Manufacturers Specification And Direction Of Engineer-In-Charge. , Providing And Fixing Aluminium Work For Doors, Windows, Ventilators And Partitions With Extruded Built Up Standard Tubular Sections/ Appropriate Z Sections And Other Sections Of Approved Make Conforming To Is: 733 And Is: 1285, Fixing With Dash Fasteners Of Required Dia And Size, Including Necessary Filling Up The Gaps At Junctions, I.E. At Top, Bottom And Sides With Required Epdm Rubber/ Neoprene Gasket Etc. Aluminium Sections Shall Be Smooth, Rust Free, Straight, Mitred And Jointed Mechanically Wherever Required Including Cleat Angle, Aluminium Snap Beading For Glazing / Paneling, C.P. Brass / Stainless Steel Screws, All Complete As Per Architectural Drawings And The Directions Of Engineer-In-Charge. (Glazing, Paneling And Dash Fasteners To Be Paid For Separately) : Neoprene Gasket Etc. Aluminium Sections Shall Be Smooth, Rust Free, Straight, Mitred And Jointed Mechanically Wherever Required Including Cleat Angle, Aluminium Snap Beading For Glazing / Paneling, C.P. Brass / Stainless Steel Screws, All Complete As Per Architectural Drawings And The Directions Of Engineer-In-Charge. (Glazing, Paneling And Dash Fasteners To Be Paid For Separately) : For Fixed Portion Less Than 12.50 Kg/Sqm) Anodised Aluminium (Anodised Transparent Or Dyed To Required Shade According To Is: 1868, Minimum Anodic Coating Of Grade Ac 15) , For Shutters Of Doors, Windows & Ventilators Including Providing And Fixing Hinges/ Pivots And Making Provision For Fixing Of Fittings Wherever Required Including The Cost Of Epdm Rubber / Neoprene Gasket Required (Fittings Shall Be Paid For Separately) Powder Coated Aluminium (Minimum Thickness Of Powder Coating 50 Micron) , Providing And Fixing Glazing In Aluminium Door, Window, Ventilator Shutters And Partitions Etc. With Epdm Rubber / Neoprene Gasket Etc. Complete As Per The Architectural Drawings And The Directions Of Engineer-In-Charge . (Cost Of Aluminium Snap Beading Shall Be Paid In Basic Item): With Float Glass Panes Of 5 Mm Thickness (Weight Not Less Than 12.50 Kg/Sqm) , Tiles Works : Providing And Laying Vitrified Floor Tiles In Different Sizes (Thickness To Be Specified By The Manufacturer) With Water Absorption Less Than 0.08% And Conforming To Is: 15622, Of Approved Make, In All Colours And Shades, Laid On 20Mm Thick Cement Mortar 1:4 (1 Cement : 4 Coarse Sand), Jointing With Grey Cement Slurry @ 3.3 Kg/ Sqm Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete. Size Of Tile 600X600 Mm , Providing And Laying Vitrified Tiles In Different Sizes (Thickness To Be Specified By Manufacturer), With Water Absorption Less Than 0.08 % And Conforming To I.S. 15622, Of Approved Make, In All Colours & Shade, In Skirting, Riser Of Steps, Over 12 Mm Thick Bed Of Cement Mortar 1:3 (1 Cement: 3 Coarse Sand), Jointing With Grey Cement Slurry @ 3.3 Kg/ Sqm Including Grouting The Joint With White Cement & Matching Pigments Etc. Complete. Size Of Tile 600X600 Mm , Providing And Fixing M.S. Grills Of Required Pattern In Frames Of Windows Etc. With M.S. Flats, Square Or Round Bars Etc. Including Priming Coat With Approved Steel Primer All Complete. Fixed To Steel Windows By Welding. , Providing And Fixing Stainless Steel ( Grade 304) Railing Made Of Hollow Tubes, Channels, Plates Etc., Including Welding, Grinding, Buffing, Polishing And Making Curvature (Wherever Required) And Fitting The Same With Necessary Stainless Steel Nuts And Bolts Complete, I/C Fixing The Railing With Necessary Accessories & Stainless Steel Dash Fasteners , Stainless Steel Bolts Etc., Of Required Size, On The Top Of The Floor Or The Side Of Waist Slab With Suitable Arrangement As Per Approval Of Engineer-In Charge, (For Payment Purpose Only Weight Of Stainless Steel Members Shall Be Considered Excluding Fixing Accessories Such As Nuts, Bolts, Fasteners Etc.) , Plastering Works : 12 Mm Cement Plaster On The Rough Side Of Single Or Half Brick Wall Of Mix : 1:4 (1 Cement: 4 Fine Sand) , 15 Mm Cement Plaster On The Rough Side Of Single Or Half Brick Wall Of Mix : 1:4 (1 Cement: 4 Fine Sand) , 20 Mm Cement Plaster Of Mix : 1:4 (1 Cement: 4 Fine Sand) , Steel Work In Built Up Tubular (Round, Square Or Rectangular Hollow Tubes Etc.) Trusses Etc., Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer, Including Welding And Bolted With Special Shaped Washers Etc. Complete. Hot Finished Welded Type Tubes , Roofing : Providing And Fixing Precoated Galvanised Iron Profile Sheets (Size, Shape And Pitch Of Corrugation As Approved By Engineer-In-Charge) 0.50 Mm (+ 0.05 %) Total Coated Thickness With Zinc Coating 120 B49grams Per Sqm As Per Is: 277, In 240 Mpa Steel Grade, 5-7 Microns Epoxy Primer On Both Side Of The Sheet And Polyester Top Coat 15-18 Microns. Sheet Should Have Protective Guard Film Of 25 Microns Minimum To Avoid Scratches During Transportation And Should Be Supplied In Single Length Upto 12 Metre Or As Desired By Engineer In-Charge. The Sheet Shall Be Fixed Using Self Drilling /Self Tapping Screws Of Size (5.5X 55 Mm) With Epdm Seal, Complete Upto Any Pitch In Horizontal/ Vertical Or Curved Surfaces, Excluding The Cost Of Purlins, Rafters And Trusses And Including Cutting To Size And Shape Wherever Required. , Providing And Fixing Precoated Galvanised Steel Sheet Roofing Accessories 0.50 Mm (+0.05 %) Total Coated Thickness, Zinc Coating 120 Grams Per Sqm As Per Is: 277, In 240 Mpa Steel Grade, 5-7 Microns Epoxy Primer On Both Side Of The Sheet And Polyester To Coat 15-18 Microns Using Self Drilling/ Self Tapping Screws Complete : Using Self Drilling/ Self Tapping Screws Complete : Ridges Plain (500 - 600Mm) , Sound Proof : Providing And Fixing Thermal Insulation With Resin Bonded Fibre Glass Wool Conforming To Is: 8183 Having Density 24 Kg/M3, 50 Mm Thick, Wrapped In 200G Virgin Polythene Bags Fixed To Wall With Screw, Rawel Plug & Washers And Held In Position By Criss Crossing Gi Wire Etc. Complete As Per Directions Of Engineer-In-Charge. , 8 Mm Thick Fully Perforated Calcium Silicate Board Made With Calcareous & Siliceous Materials Reinforced With Cellulose Fiber Manufactured Through Autoclaving Processto Give Stable Crystalline Structure With Minimumcompressive Strength 225 Kg/ Sq. Cm, Bending Strength100 Kg/Sq. Cm , Of Size 595X595 Mm, Having Perforationof Dia. 10 Mm With Minimum Perforated Area 18 % Withnon Woven Tissue On The Back Side, Having An Nrc( Noise Reduction Coefficient) Of 0.85, With 50 Mm Thickrockwool Of 48 Kg /Cum Backing , Providing And Fixing False Ceiling At All Height Including Providing And Fixing Of Frame Work Made Of Special Sections, Power Pressed From M.S. Sheets And Galvanized With Zinc Coating Of 120 Gms/Sqm (Both Side Inclusive) As Per Is : 277 And Consisting Of Angle Cleats Of Size 25 Mm Wide X 1.6 Mm Thick With Flanges Of 27 Mm And 37Mm, At 1200 Mm Centre To Centre, One Flange Fixed To The Ceiling With Dash Fastener 12.5 Mm Dia X 50Mm Long With 6Mm Dia Bolts, Other Flange Of Cleat Fixed To The Angle Hangers Of 25X10x0.50 Mm Of Required Length With Nuts & Bolts Of Required Size And Other End Of Angle Hanger Fixed With Intermediate G.I. Channels 45X15x0.9 Mm Running At The Spacing Of 1200 Mm Centre To Centre, To Which The Ceiling Section 0.5 Mm Thick Bottom Wedge Of 80 Mm With Tapered Flanges Of 26 Mm Each Having Lips Of 10.5 Mm, At 450 Mm Centre To Centre, Shall Be Fixed In A Direction Perpendicular To G.I. Intermediate Channel With Connecting Clips Made Out Of 2.64 Mm Dia X 230 Mm Long G.I. Wire At Every Junction, Including Fixing Perimeter Channels 0.5 Mm Thick 27 Mm High Having Flanges Of 20 Mm And 30 Mm Long, The Perimeter Of Ceiling Fixed To Wall/Partition With The Help Of Rawl Plugs At 450 Mm Centre, With 25Mm Long Dry Wall Screws @ 230 Mm Interval, Including Fixing Of Gypsum Board To Ceiling Section And Perimeter Channel With The Help Of Dry Wall Screws Of Size 3.5 X 25 Mm At 230 Mm C/C, Including Jointing And Finishing To A Flush Finish Of Tapered And Square Edges Of The Board With Recommended Jointing Compound , Jointing Tapes , Finishing With Jointing Compound In 3 Layers Covering Upto 150 Mm On Both Sides Of Joint And Two Coats Of Primer Suitable For Board, All As Per Manufacturers Specification And Also Including The Cost Of Making Openings For Light Fittings, Grills, Diffusers, Cutouts Made With Frame Of Perimeter Channels Suitably Fixed, All Complete As Per Drawings, Specification And Direction Of The Engineer In Charge But Excluding The Cost Of Painting With : Wedge Of 80 Mm With Tapered Flanges Of 26 Mm Each Having Lips Of 10.5 Mm, At 450 Mm Centre To Centre, Shall Be Fixed In A Direction Perpendicular To G.I. Intermediate Channel With Connecting Clips Made Out Of 2.64 Mm Dia X 230 Mm Long G.I. Wire At Every Junction, Including Fixing Perimeter Channels 0.5 Mm Thick 27 Mm High Having Flanges Of 20 Mm And 30 Mm Long, The Perimeter Of Ceiling Fixed To Wall/Partition With The Help Of Rawl Plugs At 450 Mm Centre, With 25Mm Long Dry Wall Screws @ 230 Mm Interval, Including Fixing Of Gypsum Board To Ceiling Section And Perimeter Channel With The Help Of Dry Wall Screws Of Size 3.5 X 25 Mm At 230 Mm C/C, Including Jointing And Finishing To A Flush Finish Of Tapered And Square Edges Of The Board With Recommended Jointing Compound , Jointing Tapes , Finishing With Jointing Compound In 3 Layers Covering Upto 150 Mm On Both Sides Of Joint And Two Coats Of Primer Suitable For Board, All As Per Manufacturers Specification And Also Including The Cost Of Making Openings For Light Fittings, Grills, Diffusers, Cutouts Made With Frame Of Perimeter Channels Suitably Fixed, All Complete As Per Drawings, Specification And Direction Of The Engineer In Charge But Excluding The Cost Of Painting With : Fully Perforated Gypsum Plaster Board Of Size 1200 X 2400X12.5 Mm Having Approx. 15 % Perforated Area With Perforation Size And Pattern As Approved By The Engineerin-Charge And As Per Manufacturers Specification, With All 4 Side Tapered And Backed By Acoustical Tissue With Nrc Value Not Less Than 0.60 , Painting : With Ready Mixed Pink Or Grey Primer Of Approved Brand And Manufacture On Wood Work (Hard And Soft Wood , Painting Wood Work With Deluxe Multi Surface Paint Of Required Shade. Two Or More Coat Applied @ 0.90 Ltr/10 Sqm Over An Under Coat Of Primer Applied @0.75 Ltr/10 Sqm Of Approved Brand And Manufacture , With Ready Mixed Red Oxide Zinc Chromate Primer Of Approved Brand And Manufacture On Steel Galvanised Iron/ Steel Works , Painting Steel Work With Deluxe Multi Surface Paint To Give An Even Shade. Two Or More Coat Applied @ 0.90 Ltr/ 10 Sqm Over An Under Coat Of Primer Applied @ 0.80 Ltr/ 10 Sqm Of Approved Brand And Manufacture , Providing And Applying Plaster Of Paris Putty Of 2 Mm Thickness Over Plastered Surface To Prepare The Surface Even And Smooth Complete. , Applying One Coat Of Water Thinnable Cement Primer Of Approved Brand And Manufacture On Wall Surface : Water Thinnable Cement Primer , Finishing Walls With 100% Premium Acrylic Emulsion Paint Having Voc Less Than 50 Gm/Litre And Uv Resistance As Per Is 15489:2004, Alkali & Fungal Resistance, Dirt Resistance Exterior Paint Of Required Shade (Company Depot Tinted) With Silicon Additives. New Work (Two Or More Coats Applied @ 1.43 Litre/ 10 Sqm. Over And Including Priming Coat Of Exterior Primer Applied @ 0.90 Litre/10 Sqm. , Door Window Fittings : Providing And Fixing Aluminium Sliding Door Bolts, Isi Marked Anodised (Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868), Transparent Or Dyed To Required Colour Or Shade, With Nuts And Screws Etc. Complete : 300Mm X 16Mm , Providing And Fixing Aluminium Tower Bolts, Isi Marked, Anodised (Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868 ) Transparent Or Dyed To Required Colour Or Shade, With Necessary Screws Etc. Complete : 300Mm X 10Mm , Providing And Fixing Aluminium Handles, Isi Marked, Anodised (Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868) Transparent Or Dyed To Required Colour Or Shade, With Necessary Screws Etc. Complete : 125Mm , Providing And Fixing Ptmt Butt Hinges With Necessary Screws Etc. Complete. 75X60x10 Mm Fitted With 5.5 Mm Dia M.S. Bright Bar Rod Weighing Not Less Than 34 Gms , Construction Of Inspection Banglow, Guest House (Inetrnal Electrification) Sub Head -I (Wiring) Wiring For Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Medium Class Pvc Conduit, With Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm. Frls Pvc Insulated Copper Conductor Single Core Cable Etc As Required. A) Group A , Wiring For Twin Control Light Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Medium Class Pvc Conduit, 2 Way Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm. Frls Pvc Insulated Copper Conductor Single Core Cable Etc As Required. , Wiring For Light/ Power Plug With 2X4 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface/ Recessed Medium Class Pvc Conduit Along With 1 No 4 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable For Loop Earthing As Required. , Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface/ Recessed Medium Class Pvc Conduit As Required 2 X 1.5 Sq. Mm + 1 X 1.5 Sq. Mm Earth Wire , 2 X 6 Sq. Mm + 1 X 6 Sq. Mm Earth Wire , Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface/ Recessed Steel/ Pvc Conduit As Required. 3 X 1.5 Sq. Mm , 6 X 1.5 Sq. Mm , 6 X 4 Sq. Mm , Supplying And Fixing Of Following Sizes Of Medium Class Pvc Conduit Along With Accessories In Surface/Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. 20 Mm , 25 Mm , Supplying And Fixing Suitable Size Gi Box With Modular Plate And Cover In Front On Surface Or In Recess, Including Providing And Fixing 3 Pin 5/6 Amps Modular Socket Outlet And 5/6 Amps Modular Switch, Connection Etc. As Required. (For Light Plugs To Be Used In Non Residential Buildings). , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. 3Pin 5/6 Socket Outlet , Sub Head - Ii (Mcb & Dbs ) Supplying And Fixin G Following Way, Single Pole And Neutral, Sheet Steel, Mcb Distribution Board, 240 Volts, On Surface/ Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Including Earthing Etc. As Required. (But Without Mcb/Rccb/Isolator)8 Way, Double Door , Supplying And Fixing Following Way, Horizontal Type Three Pole And Neutral, Sheet Steel, Mcb Distribution Board, 215 Volts, On Surface/ Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Including Earthing Etc. As Required. (But Without Mcb/Rccb/Isolator) 4 Way (4 + 12), Double Door , Supplying And Fixing 5 Amps To 32 Amps Rating, 240/415 Volts, C Curve, Miniature Circuit Bre Aker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.Single Pole , Supplying And Fixing Following Rating, Double Pole, 240 Volts, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 40 Amps , Supplying And Fixing Following Rating, 415 V, 10 Ka, C Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 40/63 A Tp , Sub Head-Iii (Fan,Fittings And Fixtures) Supplying, Installation, Testing And Commissioning Of 1200 Mm Sweep, Bee Five Star Rated, Ceiling Fan With Brush Less Direct Current (Bldc Motor) Not Less Than 32 W, Class Of Insulation B, 3 Nos Blade, 30 Cm Long Down Road, 2 Nos Of Canopies, Shackle Kit, Safety Rope, Copper Winding, Power Factor Not Less Than 0.9, Service Value (Cmm/W) Minimum 6.85 Air Delivery Minimum 215Cmm , 350 Rpm (Tolerance As Per Is:374-2019), Thd Less Than 10% Remote Or Electronic Regulator For Speed Control And All Remaining Accessories I/C Safety Pin, Nut Bolts , Washer, Temperature Rise=75 Degree C(Max. ), Insulation Resistance More Than 2Mega Ohm, Suitable For 230V, 50 Hz Ac Supply, Earthing Etc. Complete As Required. , Supplying, Installation Of Exhaust Fan Sweep Not Less Than 300 Mm In The Existing Opening, And Made Of Aluminium Die-Cast Motor Body, Front Protection Guard, Low Noise Operation, Robust Metal Body,Double Ball Bearing,Anti Dust,High Speed(Minimum 1350 Rpm) & High Air Delivery(Minimum 1000 Cmh) Including Making Good The Damage, Connection, Testing, Commissioning Etc. As Required. , Supplying,Installation, Testing And Commissioning Of Surface Mounted Square/Round Shape Led Downlighter Having Suitable Housing Lumen Efficacy = 100Lm/Watt, System Lumen Output = 1200 Lm, Cri = 80, Power Factor = 0.9 Having Suitable Diffuser And Cct In Between 4000K To 6500 K (I/C Both Limits) Complete With All Accessories Etc. Directly On Ceiling/Wall Including Connection With 1.5 Sq. Mm Frls Pvc Insulated, Copper Conductor, Single Core Cable And Earthing Etc. As Required. , Sub Head-Iv (Service Connection) Laying Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Following Size In The Existing Rcc/ Hume/ Metal Pipe As Required. Upto 35 Sq. Mm , Above 35 Sq. Mm And Upto 95 Sq. Mm , Supplying Of One Number Xlpe Insulated And Pvc Sheathed Aluminium Conductor Armoured Power Cable Of 1.1 Kv Grade With Isi Marked (Is 7098 (Part - I) / 1988 With Amendment Up To Date) Following Sizes. A) 3 ½ X 35 Sq.Mm , B) 3 ½ X 95 Sq.Mm , Supplying And Making End Termination With Brass Compression Gland And Aluminium Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade As Required. A) 3.5 X 35 Sqmm ( 32 Mm ) , B) 3½ X 95 Sq. Mm (45Mm) , Supplying And Fixing Of Light Class G.I. Pipe Of 80 Mm Dia. (Nominal) 3 Metres Length Along The Pole For Protection Of Under Ground Cable As Required. , Sub-Head -V( Lighting Conductor And Earthing ) Providing And Fixing Of Lightning Conductor Finial, Made Of 25 Mm Dia 300 Mm Long, G.I. Tube, Having Single Prong At Top, With 85 Mm Dia 6 Mm Thick G.I. Base Plate Including Holes Etc. Complete As Required. , Providing And Fixing G.I. Tape 20 Mm X 3 Mm Thick On Parapet Or Surface Of Wall For Lightning Conductor Complete As Required. (For Horizontal Run) , Providing And Fixing G.I. Tape 20 Mm X 3 Mm Thick On Parapet Or Surface Of Wall For Lightning Conductor Complete As Required. (For Vertical Run) , Providing And Fixing Testing Joint, Made Of 20 Mm X 3 Mm Thick G.I. Strip, 125 Mm Long, With 4 Nos. Of G.I. Bolts, Nuts, Chuck Nuts And Spring Washers Etc. Complete As Required , Earthing With G.I. Earth Plate 600 Mm X 600 Mm X 6 Mm Thick Including Accessories, And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Of 2.7 Metre Long Etc. With Charcoal/ Coke And Salt As Required. , Providing And Fixing 6 Swg Dia G.I. Wire On Surface Or In Recess For Loop Earthing As Required , Providing And Fixing 6 Swg Dia G.I. Wire On Surface Or In Recess For Loop Earthing Along With Existing Surface/ Recessed Conduit/ Submain Wiring/ Cable As Required. , Providing And Laying Earth Connection From Earth Electrode With 6 Swg Dia G.I. Wire In 15 Mm Dia G.I. Pipe From Earth Electrode Including Connection With G.I. Thimble Excavation And Re-Filling As Required , Providing And Laying G.I. Tape 32 Mm X 6 Mm From Earth Electrode Directly In Ground As Required. , Sub Head-Vii (Air Condition) Supplying, Installation, Testing And Commissioning Of Suitable Tr Capacity 5 Star Rating With Eer Not Less Than 4.3 , Split Type Inverter Air Conditioning Units Suitable For Indoor Unit To Be Fixed On The Wall Having Minimum Cooling Capacity 5400 Kcal/Hr Suitable For Single Phase Ac Supply Complete With Outdoor Unit Having Copper Condenser Coil,Suitable Clamp/Bracket For Fixing Outdoor Unit, Inter Connection With Suitable Copper Pipe Etc. Complete As Required. , Supplying , Installation, Testing And Commissioning Of Automatic Voltage Stabilizer Of Capacity 5 Kva For Air Conditioner With 130-240 Volts Range For Operation Of Air Conditioner Complete With Testing Trail Run Etc Complete As Reqd. , Supplying , Installation, Testing And Commissioning Of Automatic Voltage Stabilizer Of Capacity 5 Kva For Air Conditioner With 130-240 Volts Range For Operation Of Air Conditioner Complete With Testing Trail Run Etc Complete As Reqd. , Supply, Installation Testing & Commissioning Of Rigid Upvc Piping Complete With Fittings, Supports As Per Specifications And Duly Insulated With 6 Mm Thick Closed Cell Nitrile Rubber Insulation. A) 25 Mm Dia ( With 6 Mm Nitrile Rubber Insulation) , Construction Of Inspection Banglow, Guest House (For Sanitary & Water Supply) Providing And Fixing White Vitreous China Pedestal Type Water Closet (European Type W.C. Pan) With Seat And Lid, 10 Litre Low Level White P.V.C. Flushing Cistern, Including Flush Pipe, With Manually Controlled Device (Handle Lever), Conforming To Is : 7231, With All Fittings And Fixtures Complete, Including Cutting And Making Good The Walls And Floors Wherever Required : W.C. Pan With Isi Marked Black Solid Plastic Seat And Lid , Providing And Fixing Wash Basin With C.I. Brackets, 15 Mm C.P. Brass Pillar Taps, 32 Mm C.P. Brass Waste Of Standard Pattern, Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls Wherever Require: White Vitreous China Surgeon Type Wash Basin Of Size 660X460 Mm With A Pair Of 15 Mm C.P. Brass Pillar Taps With Elbow Including Operated Levers , Providing And Fixing Stainless Steel A Isi 304 (18/8) Kitchen Sink As Per Is:13983 With C.I. Brackets And Stainless Steel Plug 40 Mm, Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls Wherever Required : Kitchen Sink With Drain Board 510X1040 Mm Bowl Depth 250 Mm , Providing And Fixing P.V.C. Waste Pipe For Sink Or Wash Basin Including P.V.C. Waste Fittings Complete. Semi Rigid Pipe 40 Mm Dia , Providing And Fixing 600X450 Mm Beveled Edge Mirror Of Superior Glass (Of Approved Quality) Complete With 6 Mm Thick Hard Board Ground Fixed To Wooden Cleats With C.P. Brass Screws And Washers Complete. , Providing And Fixing Toilet Paper Holder : Vitreous China , Providing And Fixing Soil, Waste And Vent Pipes : 100 Mm Dia Sand Cast Iron S&S Pipe As Per Is: 1729 , Providing And Fixing Trap Of Self Cleansing Design With Screwed Down Or Hinged Grating With Or Without Vent Arm Complete, Including Cost Of Cutting And Making Good The Walls And Floors : 100 Mm Inlet And 100 Mm Outlet Sand Cast Iron S&S As Per Is: 3989 , Cutting Chases In Brick Masonry Walls For Following Diameter Sand Cast Iron/Centrifugally Cast (Spun) Iron Pipes And Making Good The Same With Cement Concrete 1:3:6 ( 1 Cement : 3 Coarse Sand :6 Graded Stone Aggregate 12.5 Mm Nominal Size), Including Necessary Plaster And Pointing In Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) : 100 Mm Dia , Providing And Fixing Ptmt Liquid Soap Container 109 Mm Wide, 125 Mm High And 112 Mm Distance From Wall Of Standard Shape With Bracket Of The Same Materials With Snap Fittings Of Approved Quality And Colour, Weighing Not Less Than 105 Gms. , Providing And Fixing Ptmt Towel Ring Trapezoidal Shape 215 Mm Long, 200 Mm Wide With Minimum Distances Of 37 Mm From Wall Face With Concealed Fittings Arrangement Of Approved Quality And Colour, Weighing Not Less Than 88 Gms. , Providing And Fixing Ptmt Towel Rail Complete With Brackets Fixed To Wooden Cleats With Cp Brass Screws With Concealed Fittings Arrangement Of Approved Quality And Colour 600 Mm Long Towel Rail With Total Length Of 645 Mm, Width 78 Mm And Effective Height Of 88 Mm, Weighing Not Less Than 190 Gms , Providing And Fixing Brass Bib Cock Of Approved Quality : 20 Mm Nominal Bor , Providing And Fixing Brass Stop Cock Of Approved Quality : 20 Mm Nominal Bor , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineer In Charge. 15 Mm Dia Nominal Outer Dia Pipes , 20 Mm Dia Nominal Outer Dia Pipes , 25 Mm Dia Nominal Outer Dia Pipes , 32 Mm Dia Nominal Outer Dia Pipes , 40 Mm Dia Nominal Outer Dia Pipes , Providing And Fixing G.I. Pipes Complete With G.I. Fittings And Clamps, I/C Cutting And Making Good The Walls Etc Internal Work - Exposed On Wall 15 Mm Dia Nominal Bore , Providing And Fixing G.I. Pipes Complete With G.I. Fittings Including Trenching And Refilling Etc. Internal Work - Exposed On Wall 20 Mm Dia Nominal Bore , 32 Mm Dia Nominal Bore Metre , 40 Mm Dia Nominal Bore , Providing And Fixing Gun Metal Non- Return Valve Of Approved Quality (Screwed End) : 20 To 40 Mm Nominal Bore , Providing And Fixing Gun Metal Gate Valve With C.I. Wheel Of Approved Quality (Screwed End) 20 Mm Nominal Bore , 32 Mm Nominal Bore , 40 Mm Nominal Bore , Providing And Fixing Gun Metal Non- Return Valve Of Approved Quality (Screwed End) : 15 Mm Nominal Bore , 20 Mm Nominal Bore , 25 Mm Nominal Bore , Providing And Fixing Gun Metal Non- Return Valve Of Approved Quality (Screwed End) : 40 Mm Nominal Bore Horizontal , Vertical , Providing And Fixing Uplasticised Pvc Connection Pipe With Brass Unions : 30 Cm Length 15 Mm Nominal Bore , 20 Mm Nominal Bore , Providing And Placing On Terrace (At All Floor Levels) Polyethylene Water Storage Tank, Is : 12701 Marked, With Cover And Suitable Locking Arrangement And Making Necessary Holes For Inlet, Outlet And Overflow Pipes But Without Fittings And The Base Support For Tank , Tube Well Boring With 100 Mm Diameter Casing Pipe For Hand Pump / Tubewell, In All Soils Except Ordinary Hard Rocks Requiring Blasting, Including Removing The Casing Pipe After The Hand Pump / Tube Well Is Lowered And Tested : Up To 6 Metres Depth , Beyond 6 M And Up To 12 M Depth , Beyond 12 M And Up To Required Depth , Providing And Placing In Position Filters Of 40 Mm Diameter G.I. Pipe With Brass Strainer Of Approved Quality. , Providing And Placing In Position Hand Pump Of Approved Quality For 40 Mm Diameter G.I. Pipe Complete With All Accessories. , Providing And Fixing G.I. Union In G.I. Pipe Including Cutting And Threading The Pipe And Making Long Screws Etc. Complete (New Work) : 50 Mm Nominal Bore , Providing And Fixing Square-Mouth S.W. Gully Trap Class Sp-1 Complete With C.I. Grating Brick Masonry Chamber With Water Tight C.I. Cover With Frame Of 300 X300 Mm Size (Inside) The Weight Of Cover To Be Not Less Than 4.50 Kg And Frame To Be Not Less Than 2.70 Kg As Per Standard Design: 150 X 100 Mm Size P Type With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 , Constructing Brick Masonry Manhole In Cement Mortar 1:4 (1 Cement : 4 Coarse Sand ) With Reinforced Cement Concrete Top Slab With 1:1.5:3 Mix (1 Cement : 1.5 Coarse Sand (Zone-Iii) : 3 Graded Stone Aggregate 20 Mm Nominal Size), Foundation Concrete 1:4:8 Mix (1 Cement : 4 Coarse Sand (Zone-Iii) : 8 Graded Stone Aggregate 40 Mm Nominal Size), Inside Plastering 12 Mm Thick With Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) Finished With Floating Coat Of Neat Cement And Making Channels In Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size) Finished With A Floating Coat Of Neat Cement Complete As Per Standard Design : Inside Size 90X80 Cm And 45 Cm Deep Including C.I. Cover With Frame (Light Duty) 455X610 Mm Internal Dimensions, Total Weight Of Cover And Frame To Be Not Less Than 38 Kg (Weight Of Cover 23 Kg And Weight Of Frame 15 Kg) : With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 , Reducing Socket, Bend, Tee, Etc. , Construction Of Septic Tank. (50 Users) Earth Work In Excavation By Mechanical Means (Hydraulic Excavator) /Manual Means In Foundation Trenches Or Drains (Not Exceeding 1.5 M In Width Or 10 Sqm On Plan), Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soil As Directed, Within A Lead Of 50 M. , Dry Brick Pitching Half Brick Thick In Drains Including Supply Of Bricks And Preparing The Surface Complete : , Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level : , Steel Reinforcement For Reinforced Cement Concrete Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Above Plinth Level. , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For , Suspended Floors, Roofs, Landings, Balconies And Access Platform , Vertical And Horizontal Fins Individually Or Forming Box Louvers Band, Facias And Eaves Boards , Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement - All Work Up To Plinth Level : , 15 Mm Cement Plaster On The Rough Side Of Single Or Half Brick Wall Of Mix : , Cement Plaster Skirting Up To 30 Cm Height, With Cement Mortar 1:3 (1 Cement : 3 Coarse Sand), Finished With A Floating Coat Of Neat Cement. , Retaining Wall Earth Work In Excavation By Mechanical Means (Hydraulic Excavator) /Manual Means In Foundation Trenches Or Drains (Not Exceeding 1.5 M In Width Or 10 Sqm On Plan), Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soil As Directed, Within A Lead Of 50 M. , Dry Brick Pitching Half Brick Thick In Drains Including Supply Of Bricks And Preparing The Surface Complete : , Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level : , Steel Reinforcement For Reinforced Cement Concrete Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Above Plinth Level. , Reinforced Cement Concrete Work In Beams, Suspended Floors, Roofs Having Slope Up To 15° Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Window Sills, Staircases And Spiral Stair Cases Above Plinth Level Up To Floor Five Level, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement With 1:1.5:3 (1 Cement : 1.5 Coarse Sand(Zone-Iii) Derived From Natural Sources : 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources). , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For , Walls (Any Thickness) Including Attached Pilasters, Butteresses, Plinth And String Courses Etc , Lintels, Beams, Plinth Beams, Girders, Bressumers And , Half Brick Masonry With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 In Superstructure Above Plinth Level Up To Floor V Level. , Providing And Fixing Stainless Steel ( Grade 304) Railing Made Of Hollow Tubes, Channels, Plates Etc., Including Welding, Grinding, Buffing, Polishing And Making Curvature (Wherever Required) And Fitting The Same With Necessary Stainless Steel Nuts And Bolts Complete, I/C Fixing The Railing With Necessary Accessories & Stainless Steel Dash Fasteners , Stainless Steel Bolts Etc., Of Required Size, On The Top Of The Floor Or The Side Of Waist Slab With Suitable Arrangement As Per Approval Of Engineer-In Charge, (For Payment Purpose Only Weight Of Stainless Steel Members Shall Be Considered Excluding Fixing Accessories Such As Nuts, Bolts, Fasteners Etc.) , Dismentling Existing A-Type Building Demolishing Reinforced Cement Concrete Work Manually/ By Mechanical Means Including Stacking Of Steel Bars And Disposal Of Unserviceable Material Within 50 Metres Lead As Per Direction Of Engineer - In- Charge. , Dismantling Doors, Windows And Clerestory Windows (Steel Or Wood) Shutter Including Chowkhats, Architrave, Holdfasts Etc. Complete And Stacking Within 50 Metres Lead : Of Area Beyond 3 Sq. Metres , Dismantling Tile Work In Floors And Roofs Laid In Cement Mortar Including Stacking Material Within 50 Metres Lead. For Thickness Of Tiles Above 25 Mm And Up To 40 Mm , Demolishing Brick Work Manually/ By Mechanical Means Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Metres Lead As Per Direction Of Engineer-In-Charge. In Cement Mortar , Dismantling Wood Work In Frames, Trusses, Purlins And Rafters Up To 10 Metres Span And 5 Metres Height Including Stacking The Material Within 50 Metres Lead : Of Sectional Area 40 Square Centimetres And Above , Dismantling Roofing Including Ridges, Hips, Valleys And Gutters Etc., And Stacking The Material Within 50 Metres Lead Of G.S. Sheet , Dismantling Aluminium/ Gypsum Partitions, Doors, Windows, Fixed Glazing And False Ceiling Including Disposal Of Unserviceable Material And Stacking Of Serviceable Material With In 50 Meters Lead As Directed By Engineer-In-Charge. , Boundary Wall With Fencing). Earth Work In Excavation By Mechanical Means (Hydraulic Excavator) /Manual Means In Foundation Trenches Or Drains (Not Exceeding 1.5 M In Width Or 10 Sqm On Plan), Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soil As Directed, Within A Lead Of 50 M. , Dry Brick Pitching Half Brick Thick In Drains Including Supply Of Bricks And Preparing The Surface Complete : , Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level : , Steel Reinforcement For Reinforced Cement Concrete Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Above Plinth Level. , Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement - All Work Up To Plinth Level : , Reinforced Cement Concrete Work In Walls (Any Thickness), Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc. Above Plinth Level Up To Floor Five Level, Excluding Cost Of Centering, Shuttering, Finishing And Reinforcement : , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For , Lintels, Beams, Plinth Beams, Girders, Bressumers And , Columns, Pillars, Piers, Abutments, Posts And Struts , Brick Work With Common Burnt Clay Modular Bricks Of Class Designation 7.5 In Foundation And Plinth In : , 15 Mm Cement Plaster On The Rough Side Of Single Or Half Brick Wall Of Mix : , 20 Mm Cement Plaster Of Mix : , Providing And Applying White Cement Based Putty Of Average Thickness 1 Mm, Of Approved Brand And Manufacturer, Over The Plastered Wall Surface To Prepare The Surface Even And Smooth Complete. , Applying One Coat Of Water Thinnable Cement Primer Of Approved Brand And Manufacture On Wall Surface : Water Thinnable Cement Primer , Finishing Walls With 100% Premium Acrylic Emulsion Paint Having Voc Less Than 50 Gm/Litre And Uv Resistance As Per Is 15489:2004, Alkali & Fungal Resistance, Dirt Resistance Exterior Paint Of Required Shade (Company Depot Tinted) With Silicon Additives. , Fencing With Reinforced Cement Concrete Post Placed At Required Distance, Embedded In Cement Concrete Blocks, Every 15Th Post, Last But One End Post And Corner Post Shall Be Strutted On Both Sides And End Post One Side Only, Provided With Horizontal Lines And Two Diagonals Of Barbed Wire Weighing 9.38 Kg Per 100 Metres (Minimum), Between The Two Posts Fitted And Fixed With G.I. Staples On Wooden Plugs Or G.I. Binding Wire Tied To 6 Mm Bar Nibs Fixed While Casting The Post (Cost Of Reinforced Cement Concrete Posts, Struts, Earth Work And Concrete To Be Paid For Separately) :- Payment To Be Made Per Metre Cost Of Total Length Of Barbed Wire Used. , Land Development Excavating, Supplying And Filling Of Local Earth (Including Royalty) By Mechanical Transport Upto A Lead Of 5Km Also Including Ramming And Watering Of The Earth In Layers Not Exceeding 20 Cm In Trenches, Plinth, Sides Of Foundation Etc. Complete. , O.H. Tank Not Found!!! , Solar Street Light Godox S60 Led Focusing Light, Outdoor & Indoor , Gate Pillarlight For Home Outdoor Garden Post Decorative Lamp , Dg Set , Audio Visual Systems Projector (Sony) , Motorised Screen And Accessories (6Ft / 8 Ft) , Digital Podium All-In-One System , Chairman Unit , Delegate Unit , Amplifier 80 Watt , Microphones , Ceiling Mount Speaker ( 6 Watt) , Wire & Lane Cabling For Speaker , Projector & Amplifier Hdmi Wire Connector Wiring Set , Installation, Testing And Commissioning Charges And Configuration Of The System , M.I. 64 -T.V. 4 Nos. @ Rs. 75000/- Per Nos. , Cctv With Motion Sensor And Sound Recorder Including Supplying & Fitting Fixing (Philips Hsp 3800) , Furniture & Fixture Sofa Set A/ Waiting Hall , B/ Executive Guest Room , C/ Suite Room , Executive Table A/ Executive Guest Room , B/ Suite Room , Executive Chair , Bed A/ Guest Room , B/ Staff Room , C/ Suite Room , D/ Security Room , Matress A/ Guest Room , B/ Staff Room , C/ Suite Room , D/ Security Room , Chair A/ Guest Room , B/ Staff Room , C/ Suite Room I)Type-I , Ii)Type-Ii , D/ Security Room , Bed Sheet A/ Guest Room , B/ Staff Room , C/ Suite Room , D/ Security Room , Pillow A/ Guest Room , B/ Staff Room , C/ Suite Room , D/ Security Room , Blanket A/ Guest Room , B/ Staff Room , C/ Suite Room , D/ Security Room , Mosquito Net A/ Guest Room , B/ Staff Room , C/ Suite Room , D/ Security Room , Bath Towel , Hand Towel , Kitchen Utensil A/ Gas Stove , B/ Pressure Cooker , B/ Cookware Set , C/ Dinner Set , D/ Cup Plate Set , E/ Cutlery Set , F/ Mixture Grinder , G/ Electric Kattle , H/ Microwave Oven , I/ Container , Conference Table , Conference Chair (Elentra-112 Steel Frame Fixed Chair)
Contract Date: Jun 16, 2026 Contract Value : 4.10 Crore
Government Departments No of Bidders 2
27.
Housing Urban and Rular Development #11294593 Technical Bid
Tender for (I) Designing, P And F, Commissioning And Testing Of Vacuum- Operated Automatic Switchover Gas Chlorination System With 1 Working Chlorinator Plus 1 Standby Chlorinator Compatible With The Existing Gas Chlorination System With Three Months Trial Run And One Year Defect Liability Period. (Ii) Designing, P And F, Commissioning And Testing Of Chlorine Gas Dry Scrubber Consisting Of Support Structures, Ductwork Of Scrubber, Blower, Dry Scrubbing Tank, Dry Scrubbing Media, Necessary Piping, Motors, Controls, Exhaust Stack And Essential Accessories With Three Months Trial Run And One Year Defect Liability Period. Pandf Of Prefab Porta Cabin Of Size 1.83 M. X 1.83 M. And Height 2.3 M. With One Side Slope Design With 50 Mm Puf Wall Panels With Pre Painted Galvanized Sheet And 20/60 Mm Corrugated Puf Roof Panels With Pre Painted Galvanized Sheet With Door, Windows Etc. Complete In All Respect. (Iii) Designing, Pand F, Commissioning And Testing Of Auto-Shut Off Valve With Three Months Trial Run And One Year Defect Liability Period. (Iv) P And F Of Dual Gas Cylinder Duly Certified And Approved By Bis And By Explosive Department Of Govt. Of India, Nagpur Of 100 Kg Capacity Cylinder As Per Is 3196 Part -Iv. (V) Providing, Fixing, Installation, Commissioning And Testing Of Chlorine Leak Detector With Alarm/Hooter. (As Per Technical Specifications Of Gaseous Chlorination System As Per Letter Of Eic, Phed, Pkl. Memo No. 23070-23142-Phe/Mont. Dated 28/02/2024 (Copy Attached). , Ht Metering Panel: Supply Indoor Type 11Kv Vcb Control Cubical Panel With Vertical Isolation Type Breaker As Per Relevant Is As Amended Up To Date And Additional Specifications, Having Capacities As Mentioned Below, Single Break Trip Free Mechanism, Manually Charged And Auto/Manually Closing Breaker Suitable For Use On 11Kv, 3 Phase 50Hz Ac, Supply With Short Circuit Fault Level Of 500 Amps Capacity, Breaker Featured With Local On/Off Indicator With Hand Trip Device, Spring Release Coil, Shunt Trip Coil And Auxiliary Switch Of 2No Plus 2Nc And Equipped With Following Switchgears And Accessories Including Making Suitable Structure Arrangement For Installation, Control Wiring And Connections Etc. As Reqd. (1 Ic Plus 2 Og) A). Vcb, 11Kv, 630Amp, 50Ka. B). 1Ph 11Kv/110 Volts Pt (Indoor Type) Class 0.2 Accuracy And 100 Va Burden -3 NoS. C). 33Kv Indoor Dead Type Dual Core Dual Ratio 3Cts Of Ratio 200-100/5-5 A Of 15 Va Burden, Ps 5 P10 And Accuracy Class 0.2. D). Control Panel- Cubicle Type Control Panel Suitable For Floor Mounting Made Out Of 1.63 Mm Cr Sheet Duly Powder Coated And With Following Relays. E). Microprocessor Based Numerical Relay For O/L, E/F And Sc Protection Suitable For Above. F). Master Trip Relay -2 NoS. G). Indicator Type Annunciator Panel With Buzzer. H). Digital Volt Meter- 0-11 Kv. I). Digital annual periodical maintenance Meter- 0-100 Amp. J). Ryb/ Trip/Closing/Spring Charged Indicator Lamp. K). Fault Annunciator Panel For O/L, Wti, Oti And Buchhloz Relay Alarm And Trip Auxiliary Relay. L). Tnc Switch For Operation. M). Multifunction Meter Em6400ng. N). Tcs Relay For Safe , Providing, Fixing, Lointing, Testing Of Mechanical Joints Complete With Rubber Gaskit, Galvanized Nuts And Bolts Including Labor, Tranportaion Ets Up To The Site. 300 Mm Nominal Diameter , Copper Cable: Supply, Erection, Testing And Commissioning Of Is Marked 3 Core Copper Cables, Solid Copper Conductor Up To 6Sqmm And Balance Stranded Copper, Xlpe Insulated, Cores Laid Up, Pvc Inner Sheathed, Armoured (Glavanised Wire For Cables Up To 10X1.5Sqmm, 8X2.5Sqmm, 2X10sqmm, 3X10sqmm, 4X6sqmm And Balance All Galvanized Steel Strip), Extruded Pvc Type St2 Outer Sheathed, /1100 V Grade As Per Is 7098 (Part 1) 1988 With Up To Date Amendments Along With All Accessories Like Thimble Lugs Etc For Motors As Per Entire Satisfaction Of Engineer-In Charge Complete In All Respect. Make:Finolex / Havells / repair renovation Cables. (150 Sqmm Size) , Ns Item -Lt Cable Alluminium: Supply, Erection, Testing And Commissioning Of Is Marked 3.5 Core Cables, Solid Aluminum Conductor Up To 10Sqmm And Balance Stranded Conductor, Xlpe Insulated, Cores Laid Up, Pvc Inner Sheathed, Armoured (Aluminium Wire For Single Core Up To 70Sqmm And Balance Aluminium Strip, Glavanised Wire For Cables Up To2x10sqmm, 3X10sqmm, 4X6sqmm And Balance All Galvanized Steel Strip) Extruded Pvc Type St2 Outer Sheathed, 650/1100V Grade As Per Is7098 (Part-1) 1988 With Up To Date Amendments Along With All Accessories Complete In All Respect. Make: Finolex / Havells / repair renovation Cables. (300 Sqmm Size). , Cloud Based Software Comprising Of Middleware, Database And Front-End Web Interface Through Suitable Dashboards, Aggregation Screens And Gis Assisted Drill-Down From Macro To Micro To Be Provided. Application Data Hosting And Maintenance For Five Years Included In Scope. Cloud Servicesof Ministry Of Electronics And Information Technology (Meity), Government Of India Empaneled Cloud Service Providers Shall Be Taken Like Microsoft, Amazon, Google, Bsnl Etc. Cloud Service Provider Must Adhere The Security Standards And Guidelines Issued By Meity From Time-To-Time. As The Data Belongs To The State Government Of Haryana, Therefore The Application And Data Hosted On Cloud Must Be Kept And Stored In Data Centres Located In India Only. Any Change In Application Requirement Or Infrastructure Shall Be Borne By The Implementation Agency. Implementation Agency Shall Carry Out The Application Security Audit From A Certified Auditor (Ca). Application And Data Shall Be Kept Confidential And Only The Authorized Users Shall Have The Access To It. Implementation Agency Shall Be Responsible For Any Data Theft Or Data Leakages. , Ns Item -Online Chlorine Sensor : Supply, Installation, Testing, Commissioning With Five Year Maintenance Of Online Chlorine Sensor. (For Mbs) , Ns Item -Rtu: Functional Integration At Rtu-Cum-Gateway For Motorized Control Valve In Pump Control Panel (For Mbs) , Ns Item -Electromagnetic Flowmeter: Supply, Installation, Testing, Commissioning Five Year Maintenance, Electromagnetic Flowmeter Along With Its Installation Complete In All Respect As Per Specifications. Size As Per Site Requirement.(Ip-68), Rs-485 Modbus. Line Size 400 Mm, Installed At Pump End / Source. (For Mbs) , Ns Item -Automation Panel: Automation Panel For Integration With Vfd With Pump Control Panel, Along With Auto/Manual Selection Switch As Well As On/Off Push Button To Be Provided. Manual Selection Between Pump 1 And Pump 2 Depending On Which To Be Operated And Which To Be Stand By To Be Provided, Along With All Relay Interlocks And Provision Of Operation Of Pumps Through Potential Free/Open Collector Digital Outputs Of Rtu-Cum-Gateway Device. The Panel Will Contain Rtu-Cum-Gateway With Necessary I/Os And Edge Controller Motorized Control Valve In Local / Remote Or Auto/ Manual Modes Of Operation In Tandem With Cloud Scheduler Or Level Sensor-Based Functions. Panel Will Contain Smps With Rechargeable Battery Backup (Min. 24 Hrs.) Along With Facility To Connect All Field Instruments With 24 Vdc Power Supply. (For Mbs , Ns Item -Radar And Water Level Transmitter: Supply, Installation, Testing, Commissioning With Five Year Maintenance Of Radar And Water Level Transmitter Alongwith According To Water Level In Ohsr (For Ohsr) Ingress Protection - Ip 66, Measuring Range - Up To 20 M, Process Temp.- -40 To 60 Deg. C, Full Pvdf Body - For A Long Sensor Lifetime. **Unit Rate Given, Actual Quantity To Be Ascertained While Placing Order. (For Mbs) , Ns Item -Sim Card: Sim Cards For Five Year Maintenance Of All The Instrument Above As Required. ( For Mbs) , Ns Item -Butterfly Valve: Supply, Installation, Testing, Commissioning With Five Year Maintenance Of Butterfly Valve With Electrical Actuator Body Material - Ci/Dipressure Rating - Pn16 Feedback - 100% Open And 100% Close. **Unit Rate Given, Actual Quantity To Be Ascertained While Placing Order 400 Mm , Ns Item - Ht. Alluminium Cable: Supply Erection Testing Of Standard Make Xlpe 3 Core Ht / 11 Kv Grade Isi Marked Stranded Compact Circular Aluminium Conductor, Conductor Screen With Extruded Semi Conducting Compound, Xlpe Insulated, Insulation Screening With Extruded Semi Conducting Compound In Combination With Copper Tape, Cores Laid Up, Innersheath Of Pvc, Galvanised Steel Flat Strip Armoured, And Overall Pvc Sheathed Cable Conforming To Is 7098 (Part-2) 2011 With Up To Date Amendments For Making Following Connection A) From G.O Switch To Metering Equipment . B) From Metering Equipment To Transformer Complete In All Respect. Make: Finolex / Havells / repair renovation Cables. (35 Sqmm Size) , Designing, Supply And Erection Of Dg Set Of Capacity Given Below With Noise Controlled Devices Acoustic Of Suitable Rating, Testing And Commissioning Of Diesel Generating Set, Radiator Cooled, 3 Phase, 4 Wire, 50 Cycles 415 Plus (-)1% Volts Ac Alternator Coupled Directly Through S Set Of Flexible Coupling On A Common Ms Fabricated Base Frame With Diesel Engine Complete With Suitable Size Incoming Cable From Generator To Change Over/Amf Panel, Making 2Nd Incoming Cable Connection From Transformer, Outgoing Cable Connection From Changeover/ Standers Panel, Making Second Incoming Cable Connection From Transformer, Outgoing Cable Connection From Changeover/ Std Panel To Incomer Of Motor Starter Panel, Fenced Enclosure With Platform For Dg Sets Complete As Per Following Detailed Scope And Specification And Directions Of Engineer-In-Charge. The Rating Should Be At 1500 Rpm. A) Diesel Engine B) Alternator C C) Battery 24 V. D) Base Plate. E) Suitable Sq Mm Suitable Core Copper Cable Upto 40 Meters. F) Tools, Standard Panel. G) Metering, Set 415 Vac-1 Set (Amp. Meter, Volt Meter, Ass, Vss, Phase Indicator, Control Fuse, Frequency Meter, CtS) H) Metering Set 60/5A//440V (Amp. Meter, Volt Meter). I) Overload Protection For Dc-1 No. J) Battery Charger 24V Dc K) Copper Bus Bar Of Suitable Size L) Kwh Meter 96 Sq Mm Size M) Starting Fuse Button And Key Switch9on/Off N) Indicating Lamps For Low Lubricated Oil Pressure, High Coolant Temperature, Set Running, Load On, Dc Control And Other Required Accessories Complete In All Respects To The Satisfaction Of Engineer-In-Charge 7. 160 Kva (As Per Parameters Of Cpcb 4) 160 Kva (As Per Parameters Of Cpcb 4) , Designing, Supply And Erection Of Dg Set Of Capacity Given Below With Noise Controlled Devices Acoustic Of Suitable Rating, Testing And Commissioning Of Diesel Generating Set, Radiator Cooled, 3 Phase, 4 Wire, 50 Cycles 415 Plus (-)1% Volts Ac Alternator Coupled Directly Through S Set Of Flexible Coupling On A Common Ms Fabricated Base Frame With Diesel Engine Complete With Suitable Size Incoming Cable From Generator To Change Over/Amf Panel, Making 2Nd Incoming Cable Connection From Transformer, Outgoing Cable Connection From Changeover/ Standers Panel, Making Second Incoming Cable Connection From Transformer, Outgoing Cable Connection From Changeover/ Std Panel To Incomer Of Motor Starter Panel, Fenced Enclosure With Platform For Dg Sets Complete As Per Following Detailed Scope And Specification And Directions Of Engineer-In-Charge. The Rating Should Be At 1500 Rpm. A) Diesel Engine B) Alternator C C) Battery 24 V. D) Base Plate. E) Suitable Sq Mm Suitable Core Copper Cable Upto 40 Meters. F) Tools, Standard Panel. G) Metering, Set 415 Vac-1 Set (Amp. Meter, Volt Meter, Ass, Vss, Phase Indicator, Control Fuse, Frequency Meter, CtS) H) Metering Set 60/5A//440V (Amp. Meter, Volt Meter). I) Overload Protection For Dc-1 No. J) Battery Charger 24V Dc K) Copper Bus Bar Of Suitable Size L) Kwh Meter 96 Sq Mm Size M) Starting Fuse Button And Key Switch9on/Off N) Indicating Lamps For Low Lubricated Oil Pressure, High Coolant Temperature, Set Running, Load On, Dc Control And Other Required Accessories Complete In All Respects To The Satisfaction Of Engineer-In-Charge 7. 200 Kva (As Per Parameters Of Cpcb 4) 200 Kva (As Per Parameters Of Cpcb 4) , Supplying, Erection, Testing And Commissioning Of Horizontal Centrifugal Clear Water Pumping Set Capacity 2780 Lpm X 50 M Head, 45 Bhp Motor, Complete With Installation At Mbs Near Yamuna River. , Design, Supply, Installation And Testing Of Vfd Along With Distribution Panel In Enclosure For Motor Rating Of 45 Hp. Enclosure Shall Be Ip54. The Panel Shall Be Equipped With Mccb Tp With Suitable Rating, Spreader Link Tp, Extended Rotary Handle, Volt Meter Digital, Volt Selector Switch, annual periodical maintenance Meter, annual periodical maintenance Selector Switch, C.T With Suitable Rating, Control Mcb Sp With Suitable Rating, Pla Relay, Pushbutton Red Plus Green With Element, Indicator On/Off, Aluminium Bus Bar/Suitable Rating Power And Control Wiring Labour And Margin, Fabrication With Minimum Sheet Thickness Of 2 Mm For Load Bearing And Non-Load Bearing Side. Vfd Should Be Capable Of Protecting Motor From High And Low Voltage And Earth Fault As Well. Vfd Should Restrict Harmonics Up To 35% Vfd Should Be Capable Of Providing Starting Torque Up To 200% While Starting Motor. It Should Have Class 3C3 (Avg)Conformal Coating So That Components Are Safe From Dust And Moisture. Communication -Built-In Rs485 Modbus Rtu, Ambient Temperature -Heavy Duty: -10 ~ 50 Deg C Normal Duty: -10 ~ 40 Deg C, Pcb Protection Conformal Coating Complying To Iec 60721-3-3 Class 3C3, Application Humidity Below Relative Humidity 95% Rh (No Condensation) Altitude 0 To 1,000 M Without Deration 1,001 To 4,000 M With Deration Of 1% Per Rise In 100 M, Vibration Up To 9.8 M/Sec2 (1.0 G), Global Compliance Ce, Ul, Rohs, Control Method V/F Control, Sensorless Vector Control, Slip Compensation, Closed Loop Vector Control. Starting Torque 200% At 0.5Hz In Sensorless Vector Control And 150% At 3Hz In V/F, Frequency Control Range 0 To 400Hz In V/F, 0 To 300Hz In Sensorless 1, 0 To 120Hz In Sensorless 2 / Vector, Frequency Precision Setting- Digital: 0.01Hz, Analog: 0.03Hz (60Hz Base). Complete With All Other Accessories As Required. (At Mbs Near Yamuna River) , Design, Construction, Erection And Commissioning Of 2 No. Ranneywell 1 At Machhrola And 1 At Jajjal (Radial Collector Well) Of 10.00 Mld Capacity With Minimum Sinking Depth Of 32 Mtr And 1000 Mtr Long Laterals Pipe In 4 Layers, All Civil, Mechanical And Electrical Works Including Transformer As Per Design Along With All Accessories And Cables, Cubicai Type Lt/Ht Panels, Vcb Panels, All Types Of Cablings With Cable Tray, Chemical Earthings Of All Machineries, 4 Vt Pumps (3W Plus 1S) Having Capacity 180.00 M³/Hr. X 30 M Head, Vfd Panels, M.S Header With All Necessary Fittings, Gantry As Per Design, Electromagnetic Flow Meters At All Outlets And Inlets, Field Office (4 Mtr X 4 Mtr With Attach Toilet), Horticulture And Landscaping (3000 Sqm) Including Purchase Of 2.50 Acre Land (For Ranneywell, Mbs And Approach Path From Revenue Rasta To Well), Earth Filling In Ranneywell Complex. 1 High Mast Street Light 12.5 Mtr High Pole With 8 Luminous Lights, Wire / Cable, Switch. Mcb And Proper Foundation Etc Complete In All Respect. 10 Cp Plus Cctv Hd Coloured Night Vision Cameras And 1 360 Degree Dome Camera Fitted At 11 M. High Pole Along With Proper Foundation With Hd Night Vision. Plc/Scada Based Automation And Monitoring System. All The Pumping Machinery, Panel Board, Flow Meter, Level Sensor Etc Shall Be Controlled By Plc And Scada And Shall Be Synchronized With Plc Panels At Ranneywell And Mbs Site Through Broadband Internet Facility. The Work Will Be Carried Out Strictly As Per Detailed Scope Of Works, Specifications, Conditions Mentioned In The Dnit And Entire Satisfaction Of Engineer-In-Charge. (80 % Capital Cost Plus 20 % O/M Cost Payement Schedule Attached With Dnit.) , Hsr Itmes
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 3
28.
Public Administrative Department #11286355 AOC
Annual Plan-KOODALI GRAMAPNCHAYATH -2024-25 MAINTENANCE WORKS TO KAVUMTHAZHA V C B-PROJECT NO-158/25-General Civil Work-- 1 VCB maintanance 2 50.2.3.1:Pumping or Bailing out water and removing slush etc by using pump set including cost of labour, oil hire charges of pumpset, etc complete 3 5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more 4 5.5:Reinforced cement concrete work in arches, archribs, domes, vaults, shells, folded plate and roofs having slope more than 15 up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 ( 1 cement :1.5 coarse sand(Zone III) : 3 graded stone aggregate 20 mm nominal size) 5 5.9.3:Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform 6 4.1.3:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size) 7 13.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) 8 OD347090/2024-2025:Shutter for check dams- Supplying and providing Thambagam wood shutter planks 5cm thick including cost of materials and labour charges etc complete 9 13.59:Coal tarring two coats on new work using 0.16 litre and 0.12 litre coal tar per sqm in the first coat and second coat respectively. 10 50.10.2:Steel work for purlin/single section with G I pipes including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete 11 15.9.2:Demolishing stone rubble masonry manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer -in- Charges:In cement mortar 12 2.8.1:Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil 13 OD353643/2024-2025:DEPARTMENTAL -DRY RUBBLE_ Dry rubble without concrete levelling course masonry with good quality blasted rubble including packing to compactness to lines and levels cost and conveyance of all materials labour charges etc. complete as per direction of Departmental officers at site 14 7.1.1:Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand)
Contract Date: Jun 15, 2026 Contract Value : 2.78 Lakh
Government Departments No of Bidders 1
29.
Housing Urban and Rular Development #11285695 AOC
Tender For Grading Roof For Water Proofing Treatment With Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size) , Providing And Laying Water Proofing Treatment On Roofs Of Slabs By Applying Cement Slurry Mixed With Water Proofing Cement Compound Consisting Of Applying: (A) After Surface Preparation, First Layer Of Slurry Of Cement @ 0.488 Kg/Sqm Mixed With Water Proofing Cement Compound @ 0.253 Kg/Sqm. (B) Laying Second Layer Of Fibre Glass Cloth When The First Layer Is Still Green. Overlaps Of Joints Of Fibre Cloth Should Not Be Less Than 10 Cm. (C) Third Layer Of 1.5 Mm Thickness Consisting Of Slurry Of Cement @ 1.289 Kg/Sqm Mixed With Water Proofing Cement Compound @ 0.670 Kg/Sqm And Coarse Sand @ 1.289 Kg/Sqm. This Will Be Allowed To Air Cure For 4 Hours Followed By Water Curing For 48 Hours. The Entire Treatment Will Be Taken Upto 30 Cm On Parapet Wall And Tucked Into Groove In Parapet All Around.(D) Fourth And Final Layer Of Brick Tiling With Cement Mortar (Which Will Be Paid For Separately.For The Purpose Of Measurement The Entire Treated Surface Will Be Measured. , Cement Plaster 1:3 (1 Cement: 3 Coarse Sand) Finished With A Floating Coat Of Neat Cement.20 Mm Cement Plaster , Extra For Providing And Mixing Water Proofing Material In Cement .Plaster Work In Proportion Recommended By The Manufacturers , Demolishing Reinforced Cement Concrete Work Manually/ By Mechanical Means Including Stacking Of Steel Bars And Disposal Of Unserviceable Material Within 50 Metres Lead As Per Direction Of Engineer - In- Charge. , Demolishing Cement Concrete Manually/ By Mechanical Means Including Disposal Of Material Within 50 Metres Lead As Per Direction Of Engineer - In - Charge. Nominal Concrete 1:3:6 Or Richer Mix (I/C Equivalent Design Mix) , Dismantling Doors, Windows And Clerestory Windows (Steel Or Wood) Shutter Including Chowkhats, Architrave, Holdfasts Etc. Complete And Stacking Within 50 Metres Lead : Of Area 3 Sq. Metres And Below . , Reinforced Cement Concrete Work In Beams, Suspended Floors, Roofs Having Slope Up To 15° Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Window Sills, Staircases And Spiral Stair Cases Above Plinth Level Up To Floor Five Level, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement, With 1:1.5:3 (1 Cement : 1.5 Coarse Sand (Zone-Iii) : 3 Graded Stone Aggregate 20 Mm Nominal Size). , Reinforcement For Reinforced Cement Concrete Mild Steel And Medium Tensile Steel Bars Including Straightening, Cutting, Bending In Position And Binding All Complete. , Centring And Shuttering For Suspended Floors, Roofs, Landings, Balconies And Access Platform. , Centring And Shuttering For Lintels, Beams, Plinth Beams, Girders, Bressumers And Cantilevers. , Brick Work With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 In Superstructure Above Plinth Level Up To Floor V Level In All Shapes And Sizes In :Cement Mortar 1:6 (1 Cement : 6 Coarse Sand) , 12 Mm Cement Plaster Of Mix 1:6 (1 Cement : 6 Fine Sand) , Repair To Plaster Of Thickness 12Mm To 20 Mm In Patches Of Area 2.5 Sqm And Under, Including Cutting The Patch In Proper Shape, Raking Out Joints And Preparing Plastering The Wall Surface With White Cement Based Polymer Modified Self Curing Mortar, Including Disposal Of Rubbish, All Complete As Per The Direction Of Engineer-In-Charge. , Removing Dry Or Oil Bound Distemper, Water Proofing Cement Paint And The Like By Scrapping, Sand Papering And Preparing The Surface Smooth Including Necessary Repairs To Scratches Etc. Complete. , Distempering With Oil Bound Washable Distemper Of Approved Brand And Manufacture To Give An Even Shade New Work (Two Or More Coats) Over And Including Priming Coat With Cement Primer. , Finishing Walls With Premium Acrylic Smooth Exterior Paint With Silicone Additives Of Required Shade :New Work (Two Or More Coats Applied @ 1.43 Ltr/ 10 Sqm Over And Including Priming Coat Of Exterior Primer Applied @ 2.20 Kg/ 10 Sqm) , Kota Stone Slab Flooring Over 20 Mm (Average) Thick Base Laid Over And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab, Including Rubbing And Polishing Complete With Base Of Cement Mortar 1 : 4 (1 Cement : 4 Coarse Sand) : , Kota Stone Slabs 20 Mm Thick In Risers Of Steps, Skirting, Dado And Pillars Laid On 12 Mm (Average) Thick Cement Mortar 1:3 (1 Cement: 3 Coarse Sand) And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slabs, Including Rubbing And Polishing Complete. , Providing And Fixing M.S. Grills Of Required Pattern In Frames Of Windows Etc. With M.S. Flats, Square Or Round Bars Etc. Including Priming Coat With Approved Steel Primer All Complete.Fixed To Steel Windows By Welding , Providing And Fixing 1Mm Thick M.S. Sheet Door With Frame Of 40X40x6 Mm Angle Iron And 3 Mm M.S. Gusset Plates At The Junctions And Corners, All Necessary Fittings Complete, Including Applying A Priming Coat Of Approved Steel Primer. Using M.S. Angels 40X40x6 Mm For Diagonal Braces , Providing And Fixing Fly Proof Galvanized M.S. Wire Gauge To Windows And Clerestory Windows Using Wire Gauge With Average Width Of Aperture 1.4 Mm In Both Directions With Wire Of Dia 0.63 Mm All Complete With 12 Mm Mild Steel U Beading , Providing And Fixing Isi Marked Oxidised M.S. Sliding Door Bolts With Nuts And Screws Etc. Complete : 300X16 Mm , Providing And Fixing Isi Marked Oxidised M.S. Tower Bolt Black Finish, (Barrel Type) With Necessary Screws Etc. Complete : 250X10 Mm , Providing And Fixing Isi Marked Oxidised M.S. Handles Conforming To Is:4992 With Necessary Screws Etc. Complete :.1 125 Mm , Painting Steel Work With Deluxe Multi Surface Paint To Give An Even Shade. Two Or More Coat Applied @0.90 Ltr/10 Sqm Over An Under Coat Of Primer Applied @ 0.80 Ltr/ 10 Sqm Of Approved Brand Or Manufacture. , Providing And Fixing On Wall Face Unplasticised Rigid Pvc Rain Water Pipes (110 Mm Diameter) , Providing And Fixing On Wall Face Unplasticised - Pvc Moulded Fittings/ Accessories For Unplasticised Rigid Pvc Rain Water Pipes Conforming To Is : 13592 Type A, Including Jointing With Seal Ring Conforming To Is : 5382, Leaving 10 Mm Gap For Thermal Expansion. Shoe (Plain) 110 Mm , Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level : 1:2:4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size) , Add For Plaster Drip Course/ Groove In Plastered Surface Or Moulding To Reinforced Cement Concrete Projections.
Contract Date: Jun 12, 2026 Contract Value : 16.17 Lakh
Government Departments No of Bidders 11
Uttarakhand View Result →
30.
Defence #11281747 Technical Bid
Tender For Provision Of Defi Md Accommodation At Kota Mil Stn; 1 Lump sum price worked out by the contractor for BUILDING WORKSas listed in Schedule ‘A’ Part-I representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES 2 Lump sum price worked out by the contractor for INTERNAL WATER SUPPLY as listed in Schedule ‘A’ Part-II representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES 3 Lump sum price worked out by the contractor for INTERNAL ELECTRIFICATIONas listed in Schedule ‘A’ Part-III representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES 4 Lump sum price worked out by the contractor for ROAD, PATH, CULVERT AND HARD STANDINGas listed in Schedule ‘A’ Part-IV representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES 5 Lump sum price worked out by the contractor for SEWAGE DISPOSALas listed in Schedule ‘A’ Part-V representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES 6 Lump sum price worked out by the contractor for AREA DRAINAGE as listed in Schedule ‘A’ Part-VI representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES 7 Lump sum price worked out by the contractor for FENCINGas listed in Schedule ‘A’ Part-VII representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES 8 Lump sum price worked out by the contractor for EXTERNAL WATER SUPPLYas listed in Schedule ‘A’ Part-VIII representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceof prepriced by the MES 9 Lump sum price worked out by the contractor for EXTERNAL ELECTRIFICATIONas listed in Schedule ‘A’ Part-IX representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceof prepriced by the MES 10 Lump sum price worked out by the contractor for LIGHTING PROTECTION as listed in Schedule ‘A’ Part-X representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES 11 Lump sum price worked out by the contractor for FIRE FIGHTINGas listed in Schedule ‘A’ Part-XI representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceof prepriced by the MES 12 Lump sum price worked out by the contractor for LIFT WORKas listed in Schedule ‘A’ Part-XII representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceof prepriced by the MES 13 Lump sum price worked out by the contractor for HOT WATER SUPPLYas listed in Schedule ‘A’ Part-XIII representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceof prepriced by the MES 14 Lump sum price worked out by the contractor for DG SETSas listed in Schedule ‘A’ Part-XIV representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceof prepriced by the MES 15 Lump sum price worked out by the contractor for SITE CLEARANCE, SITE DEVELOPMENTAND EARTH WORKas listed in Schedule ‘A’ Part-XV representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES 16 Sch A Part-XVI MISC ITEMS (TO BE QUOTED BY CONTRACTOR) Notes:(i) This schedule is not pre-priced by MES and the pre-priced rate indicated as Rs 0.00 under column 5 signifies this fact only. (ii) Excavation and earth work except for the items which categorically includes for same shall be measured and paid separately under SCH A PART-XVSITE CLEARANCE, SITE DEVELOPMENTAND EARTH WORK schedule). 17 INTERNAL WATER SUPPLYS&F for 15mm dia sink mixer (wall mounted) with 150mm long swivel spout,connecting legs and wall flangerswith complete accessories etc complete all as specified and directed.Make: CERA Cat Part No F2014511 / Hindware Cat Part No F690058 / Parryware Cat Part No G3335A1 or equivalent make as mentioned in Appx B. 18 S&F for 15mm dia single lever center hole basin mixerwith complete accessories etc complete all as specified and directed.Make: CERA Cat Part No F1015451 / Hindware Cat Part No F690012 / Parryware Cat Part No G4863A1 or equivalent make as mentioned in Appx B. 19 S&F for 15mm dia wall mixture with bend pipe for overhead showerwith complete accessories etc complete all as specified and directed.Make: CERA Cat Part No F2002401 / Hindware Cat Part No F330020 / Parryware Cat Part No G3316A1 or equivalent make as mentioned in Appx B. 20 INTERNAL ELECTRIFICATIONS&F ofmodular type 3 pin 20 A socket with SP MCB, conforming to IS 1293: 2005as specified in IS 732: 2019 etc complete all as specified and directed 21 S&F for modular type 1 module RJ-11 telephone socket with shutter etc complete all as specified and directed 22 S&F for modular type 1 module co-axial type TV socket etc complete all as specified and directed 23 S & F for 16 A, 230 V, 50 Hz, 2P MCB (B curve) MCB conforming to IS/IEC 60898-1-2002, having breaking capacity Icn = 10 kA, sliding bottom clamp, colour coded on/off indication on dolly, bi-connect IP 20 protected lower terminals and sliding shutters,IS 732: 2019 etc complete all as specified and directed 24 S & F for 25 A, 230 V, 50 Hz, 2P MCB (B curve) MCB conforming to IS/IEC 60898-1-2002, having breaking capacity Icn = 10 kA, sliding bottom clamp, colour coded on/off indication on dolly, bi-connect IP 20 protected lower terminals and sliding shutters,IS 732: 2019 etc complete all as specified and directed 25 S & F for 32 A, 230 V, 50 Hz, 2P MCB (B curve) MCB conforming to IS/IEC 60898-1-2002, having breaking capacity Icn = 10 kA, sliding bottom clamp, colour coded on/off indication on dolly, bi-connect IP 20 protected lower terminals and sliding shutters,IS 732: 2019 etc complete all as specified and directed 26 S & F for 40 A, 230 V, 50 Hz, 2P MCB (B curve) MCB conforming to IS/IEC 60898-1-2002, having breaking capacity Icn = 10 kA, sliding bottom clamp, colour coded on/off indication on dolly, bi-connect IP 20 protected lower terminals and sliding shutters,IS 732: 2019 etc complete all as specified and directed 27 S&F forSingle Phase Dual Source Pre Paid Meter, Class 1.0, RS485,10/60A Direct,with followingspecification as under : (i) Communication options:, RS485 and RF(ii)Three in one option:Integrate gas & waterupto 4 DI(iii) Programmable tariff for EB, DG and DI for automatic reduction of balance even server is offline(iv) Configurable Holidays,Happy hours to avoidload switching on Holidays/Night(v) Alarm notifications for low credit balance(vi) Eliminate tenantdisputes, meter tampering & manualtariff reading errors 28 S&F forThree Phase Dual Source Pre Paid Meter, Class 1.0, RS485, 5A CT operated,with followingspecification as under : (i) Communication options:, RS485 and RF(ii)Three in one option:Integrate gas & waterupto 4 DI(iii) Programmable tariff for EB, DG and DI for automatic reduction of balance even server is offline(iv) Configurable Holidays,Happy hours to avoidload switching on Holidays/Night(v) Alarm notifications for low credit balance(vi) Eliminate tenantdisputes, meter tampering & manualtariff reading errors 29 S&F of Sheet metal enclosure distribution board VTPN4 way, 415 voltdouble door powder coated, protection class IP-54 isolated neutral bar, mechanical impact strength IK 09 suitable for mounting MCB & MCCB DBs confirming to IS - 13032, IS-8623, BS EN60898 with min 200 Amp rating copper bus bar and grouting, fixing on wall with nut bolts washers proper with PCC works complete all as specified and directed 30 S&F of Sheet metal enclosure distribution board VTPN6 way, 415 voltdouble door powder coated, protection class IP-54 isolated neutral bar, mechanical impact strength IK 09 suitable for mounting MCB & MCCB DBs confirming to IS - 13032, IS-8623, BS EN60898 with min 200 Amp rating copper bus bar and grouting, fixing on wall with nut bolts washers proper with PCC works complete all as specified and directed 31 S&F of 160A, 4 pole moulded case circuit breaker (MCCB) with thermal magnetic trip unit (TMD), compression lug connectors, protection against overloads (Ir adjustable from 0.7- 1 X In), protection against short circuits (Isd adjustable from 5- 10 X Ir), inbuilt encapsulated double break roto active type instanteneous protection, earth fault leakage protection, etc. having Ics = 100% = Icu = 16 kA as per IEC 60947-2 and suitable for 3-Phase, 415 V, 50 Hz electric supply etc complete all as specified and directed by engineer-in-charge. 32 S&F for 12W LED Downlight having Luminous efficacy of > 100, input voltage range 140-270 V, input frequency 50-60 Hz etc complete all as specified and directed . 33 S&F for LED light fitting with high 10 watt 220 V AC decorative wall type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size etc complete all as specified and directed . 34 S&F for 10W LED bulk head light having Luminous efficacy of > 100, input voltage range 140-270 V, input frequency 50-60 Hz etc complete all as specified and directed. 35 Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 600 mm sweep. Min air delivery 115 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) etc complete all as specified and directed by engineer-in-charge. 36 Supply and fix Wall Mounting Fan, steel body AC single Phase, 230V,With Sweep Size, 200mm ; Motor Speed 84CMM, 3 blades, and frame and louvers etc complete all as specified and directed by engineer-in-charge. 37 Supply, installation, testing and commissioning of factory made, indoor cubical compartmental type BUILDING PANEL (TTA) of suitable size for short circuit, temperature rise, protective earth short circuit test and dielectric tests of required ratings, conforming to IEC 61439-1 & 2 and IEC 61641, having both sides openable with hinged double doors and locking arrangement, IP 42 protection made out of 2.0 mm thick mild steel CRCA sheet, supported and fixed on structural frame of angle iron of suitable size, including earthing stud, labelling, painting to all internal & external exposed steel surfaces with powder coating paint (7 tank process), duly fixed in ground with PCC foundation (1:2:4) type B1, with danger notice plate of 1.6 mm thick mild steel vitreous enameled (white) with letters, figures and conventional skull and bones in signal red colour suitable for 3- Phase, 4 Wire system, 500 V grade with necessary wiring, PVC sheathed stranded copper conductor of appropriate length and size, including fixing lugs, bolts, screws, etc. complete as specified and directed by engineer-in-charge.The BUILDING PANEL shall comprise of the following:(A) Bus bar Chamber(i) 01 Set (3L + N) of copper busbar of rated capacity 400A, covered with PVC insulated sleeves including insulator, nuts, bolts, etc. with complete connections. 38 (B) Incoming:- (i)320A, 415 V, Ics = 100% Icu = 16 kA, 50 Hz 4P MCCB, conforming to IEC 60947-2, having microprocessor based trip unit, adjustable overload setting (0.7 - 1 X In), adjustable short-circuit setting (5 - 10 X Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (ready, overload and pre-alarm & overload)- 01 No.(ii) Cl 1.0 multi-function meter capable of measuring V, A, F, PF, W/VA, Wh/VAh, Runhrs. Onhrs & interupts- 01 No.(iii) LED phase indicators (Red, Yellow, Blue)- 01 Set 39 (C) Outgoing:-(i)40A, 415 V, Ics = 100% Icu = 16 kA, 50 Hz 4P MCCB, conforming to IEC 60947-2, havingtrip unit, adjustable overload setting (0.7 - 1 X In), adjustable short-circuit setting (5 - 10 X Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (ready, overload and pre-alarm & overload)- 08 Nos(ii) LED phase indicators (Red, Yellow, Blue)- 08 Sets 40 SEWAGE DISPOSALS&F for DWCPE (SN8) 180mm outer dia and 163 inner dia of pipe for depth 0.70mm to 1.65m, laid on 150 mm thick bed (1:4:8)with excavation in any type of soil including manholes/drop manhole of standard sizemade of brick mosonary /RCC/Precast RCC with SFRC ventilating cover and frame,includes all items and activities to execute and make sewer line functionaletc complete all as specified and directed. 41 S&F for DWCPE (SN8) 200mm outer dia and 175 inner dia of pipe for depth 0.70mm to 1.65m, laid on 150 mm thick bed (1:4:8) with excavation in any type of soil including manholes/drop manhole of standard sizemade of brick mosonary /RCC/Precast RCC with SFRC ventilating cover and frame,includes all items and activities to execute and make sewer line functionaletc complete all as specified and directed. 42 S&F for DWCPE (SN8) 300mm outer dia and 260 inner dia of pipe for depth 1.65mm to 2.3m, laid on 150 mm thick bed (1:4:8) with excavation in any type of soil including manholes/drop manhole of standard sizemade of brick mosonary /RCC/Precast RCC with SFRC ventilating cover and frame,includes all items and activities to execute and make sewer line functionaletc complete all as specified and directed. 43 Supply, lay, commissioning, jointing and testing ofcentrifugally cast (spun) ductile iron pipes of 150mm bore class K-7 with spigot and socket ends conforming to IS 8329/2000, IS: 12288 : 1987 code of practice for laying in trenches complete all as specified and directed.Note: The rate quoted by contractor are inclusive of all type of Joints. 44 S&F forNonclog submersible (sewage disposal), pump set, electric driven 415 Volts 3 Phase 50 Hz, supply comprising of pump with cast iron impellors, submersible motor of suitable capacity, coupling, at discharge 3360 to 480 LPM and minimum discharge should be less than 480 LPM at minimum head 14 m.including chain pully block of two MT capacity 01 Noandsuitable arrangement for hanging the motor through chain of requirement of delivery of pump connected to main pipe line by suitabe HDPE pipe of size 150mm Dia for required length with necessary connection etc all as specified and as directed. 45 Supply,installing, testingand commissioningout door type LT feeder piller box of suitable size 750X750X450 mm, pedestal mounted, CPRI type test totally enclosed, dust and vermin proof, double leaf shutter in front and single leaf shutter in rear side made of 3.15 mm thick CRCA sheet, framing with 50 x50 x 6 mm thick MS angle iron and legs of size 0.5m long . duly fabricated and having proper locking arrangement in both front and rear door with 4 side slanting roof duly projected and paintedto both internal and External surfaces with powder coating paint in heatprocess of sheet and suitable for 415 volts, 50 Hz, 3 phase 4 wire system and comprising with and includingfollowing accessories and mounted on PCC Platform made out of100 mm thick PCC (1:3:6),0.45 Mtr all round the panel board etc complete with the following items :- 46 Incoming:- (i) Copper bus bar made up of copper strip100 amps duly mounted on bakelite insulatorssleevings of standard colour code - 01 Set. (04 No strips for Phases & Neutral)(ii) MCCB TPN 415 Volts,63 Amps, 50 Hz, breaking capacity 25 KA with fixed thermal & magnetic setting ( For Incomming ) - 01 No.Outgoing:-(i) MCB TP 415 volts 32 Amps, breaking capacity 16 KA with fixed thermal & magnetic setting ( For FPB2 ) - 03 Nos(2 nos for pump 1 nos for spare). (ii) FASD Starter for 15 HP Motor with single phase preventer, OLP and dry run protector- 02 Nos 47 (iii) Analogue type modular volt meterof range 0-500 volts -01 No(iv)Volt meter selector switch-01 No.(v) Analogue typeAmmeter of range 0-200 Amp-01 No(vi) Ammeter selector switch-01 No(set of three)(vii) Indicator lamp with integral circuit (230/240 volt) and cluster LED (Red, Orange, Blue) - 01 set(viii) CT 200/5 Amps - 3 Nos 48 Supply and FixingDI/CI special fittings of any size,type,radius angle,tapers increasing decreasing sockets,tees,tail piece and collars etc complete upto 200 mm dia etc complete all as specified and directed. 49 S&F forPVC insulated and sheathed 1100 volts grade flat type submersible 06 sqmm cable three core multi stranded conductor etc complete all as specified and directed . 50 M&L for Making drill hole by trenchless technologyof suitable size under road for laying pipe line of size150mm bore at 1 metre depth from the road level etc complete all as specified and directed.Note :- Drill hole (trenchless) shall be done without disturbing top surfaces of road by appropriate machine. 51 M&L for steel gate 5.45 m wide and 2.70 m height with RCC pillar including excavation in any type of soil, plastering, painting, etc complete all as specified and shown in TD/2008/101 sheet No 1/3 to 3/3 52 EXTERNAL WATER SUPPLY Supply, lay, commissioning, jointing and testing ofcentrifugally cast (spun) ductile iron pipes of 100mm bore class K-9 with spigot and socket ends conforming to IS 8329/2000, IS: 12288 : 1987 code of practice for laying in trenches complete all as specified and directed.Note: The rate quoted by contractor are inclusive of all type of Joints. 53 Supply, lay, commissioning, jointing and testing ofcentrifugally cast (spun) ductile iron pipes of 150mm bore class K-9 IS: 12288 : 1987 code of practice for laying in trenches complete all as specified and directed.Note: The rate quoted by contractor are inclusive of all type of Joints. 54 Supply and FixingDI/CI special fittings of any size,type,radius angle,tapers increasing decreasing sockets,tees,tail piece and collars etc complete upto 200 mm dia etc complete all as specified and directed. 55 Supply and fix CI foot valve with leather washer, ofsize 100 mm , lift and swing, single door, IS 4038 marked one with each pump suction line complete all as specified and directed. 56 M&L for construction of valve chamber of brick masonry from the top of surface with MS covers 3.15 mm thick and 40x40x6 mm MS angle with hinges for locking arrangement including excavation and earth works PCC (1:3:6) type C2 for foundation PCC bed/coping in cement concrete (1:2:4) type B1, plastering in CM 1:3 painting with two coats of synthetic enamel paint over a coat of red oxide primerfor the size of chamber 1200 mm x 1200 mm x 1200 mm (internal dimention) complete all as specified and directed. 57 Supply, install,commissioning and testing of Horizontal split case cetrifugal pump set 1450 RPM having an output of minimum 1100 LPM at a head of 45 mtr coupled to 3 phase 415 volt squirel case induction motor of adequate capacity complete all as ditected by Engr-in-charge with and including following :-(a) Necessary cable for interconnection between starter panel & pump set with 1100 volt rated copperinsulated unarmoured cable of minium 10 sqmm 3 core cable(b) Single phase preventer (current sensing type)(c) Necessary light grade GI pipe protection for cabling from pump set to LT panel.(d) Bourden pressure gauge.(e) MS pipe flanged type class B of size 100 mm bore upto foot valve from suction end of pump.(f) PCC foundation in type B-2, 1:2:4 using 20mm graded aggregate, 20cm above ground level and 30cm below grond level including grouting of eye bolts nut etc. for pump set of adequate size or as per manufacturers recommendations.Note: All other items/material requiredfor fixing pumpset shall be included in cost quoted.(ii) Foundation drawing shall be approved by GE/ Eng-In- Charge before fixing the pump set. 58 Supply, installations, testing and commissioning of factory made LT Indoor cubical typepanel boardhaving 150 Amp rated copper bus bar with neoprene rubber gasket and locking arrangement, dust,weather and verminproof , free standing, floor mounting type self ventilation with wire mesh,totally enclosed busbar chamber fully comparted type, front openable hinged independent door for each compartment with locking arrangement and common openable hinged door from rear side of suitable size made out of 2mm thick CRCA sheet duly painted with seven tank process,415 V,TPN,50Hz both side properly welded MS angular supported with chanel frame of size 50mm,at all vertical corner grouted in PCC 1:3:6 (Type-C1 using 20mm graded stone aggregate) and connecting the incomming/outgoing feeder by providing brass cable glands and Lugs complete all as specified and directed comprising of followings accessories:- 59 Incoming:- (i) MCCB 4 Pole 100 amps ,415 Volt of breaking capacity not less than 36 KA (Ics=100 % of Icu) with adjustable thermal Setting-01 No.Outgoing:-(i)MCCB 3 Pole 63 amps ,415 Volt of breaking capacity not less than36 KA (Ics=100 % of Icu) with adjustable thermal Setting - 02 Nos (ii) Single phase preventor -02 Nos(iii) On load Change over switch 4 pole of current raring 63 A (open execution type) - 01 No(iv)MCB SPN 10 Amp C curve, 10 KA capacity - 01 No(v) fully automatic Star-delta starter 15 HP or recommended by manufacturer of motor -02 Nos(vi) LED Indicator lamp (R,Y,B)- Set of Three.(vii) Multifunctional meterDigital type showing V,A,F,Pf,KW,KWH inbuilt selector switch with CT coiles for three phase -0 1No. 60 M&L for construction of header of ERW pipe having size dia 300 mm and length 2.5 m with two inlet connection of size 100 mm & three otlet connection having size 150 mm complete monting on RCC base/plinth etc complete all as specified and as directed by Engr-in-charge. 61 EXTERNAL ELECTRIFICATIONBoring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine for laying under ground pipe upto 100mm dia complete all as specified and directed.Note :- GI pipe shall be measured and paid separately. 62 Taking out existing HT XLPE U/G cables, 11000 V grade from trenches/ducts/ poles etc of size 120 Sq. mm 3 Core etccomplete all as specified and directed. 63 Dismantling and taking down existing transformer mounted on four pole structure and shifting to nearest suitable location including its fixing on newly constructed platform and making all connection, testing as per requirementetccomplete all as specified and directed. 64 Dismantling and taking down existing 4-pole structure etccomplete all as specified and directed. 65 Dismantling and taking down existing 03 Nos of LT Panels, refixing at specified locationincluding connecting etc complete all specified and directed. 66 Taking out existing LT XLPE U/G cables, 1100 V grade from trenches/ducts/ poles etc of size 240 Sq. mm 3.5 Core etc complete all as specified and directed. 67 Taking out existing LT XLPE U/G cables, 1100 V grade from trenches/ducts/ poles etc of size 185 Sq. mm 3.5 Core etc complete all as specified and directed. 68 Taking out existing LT XLPE U/G cables, 1100 V grade from trenches/ducts/ poles etc of size upto 95 Sq. mm 3.5 Core etc complete all as specified and directed.Note For item No. 57 to 63 :- The old material obtained from site shall be deposite by contractor in MES store yard without any extra cost as directed by GE. 69 M&L for construction of plateform of size 3500 x 3500 x 1200mm with brick construction in cement mortar 1:4 PCC (M-10 nominal mix) in foundation, 100mm thick RCC M-25 grade slab, with 8mm MS TMT bars 120mm c/c on bothway, brick masonary steps on one side XPM Jali fixed on angle iron 40x 40x6 mm post upto height of 8 feet above ground level and openable gate with locking arrangment including making provision for entry and exit of HT/LT cables and steps made to access to the top of plateform including plastering to bricks masonary complete including painting with 2 coats of whitewash on plastered surface and painting steel surface with 2 coats of red oxide primeretc complete all as specified and directed. 70 Supply & fix HT 11 KV, outdoor type gang operated air-break switch suitable for horizontal or vertical mounting rotating type complee with drop out fuse having 12 insulators of rating upto 200 Amps etc complete all as specified and directed. 71 Supply and fixing lightning arrestor HT 11 KV, 10 KA station class etc complete all as specified and directed. 72 Supply & errect 2 pole structure on 11 mtr PCC pole consisting of pole with anti-climbing device, PCC foundation & cross arms (Bracings) etc for one incoming and one out going. etc complete all as specified and directed. 73 Supply, installation, testing & commissioning of package type/unitised 11kV / 433 V Outdoor sub-station (CSS) ,315KVA made from G. I. enclosure complete as required conforming to IEC 62271-202 only and relevant IS specifications including K-10 Temperature Class as applicable for the rating, Internal Arc of 21 KA/1 Sec. IAC AB on 1:2:4 (1 cement :2 cores and : 4 Graded stone aggrregate of 40 mm nominal size) PCC foundation of suitable size extending 500 mm all around the outdoor enclosure and 1000 mm height (above ground level) complete with suitable sizes of GI Pipes for incoming/outgoing cables/earthing strips etc. and consisting of following complete as required. Angle iron frame of size 40x40x5mm NS all along the corner of the foundation CSS shall be from OEMs only . Licensed System Integrators of approved OEM are not allowed to supply .Package substation will have the following equipment :- 74 HT SWITCHGEAR11kV 630Amps 21KA/3 sec. Non-Extensible Ring Main Unit Compact switchgear consisting of1 no. fixed motorized Vacuum Circuit Breaker Moduleand 2 nos. fixed morotized Load break switch module in SF6 insulated stainless steel enclosure with series trip, self powered microprocessor based numerical over current and earth fault relay protection. HT RMU shall preferably have site replaceable bushings to have very less downtime in the event of bushing breakage and restoration can be done immediately without sending the RMU to OEM Works. Interconnection between HT Switchgear and primary of transformer shall be done through 1C x 3R x 95 sq.mm Aluminium XLPE cable. - 1 No.Vacuum Interrupter,RMU,LT Switchgear and CSS Enciosure shall be of same make to ensure life cycle optimization.(i)Microprocessor based IDMT Relay for Circuit Breakers - Self Powered along with series trip coil (Modbus RS485 complaint)(ii)Capacitive voltage indication fixed type system with LED for all feeder and FPI in all load break switch feeder.(iii)SF6 Gas pressure indicator.(iv)Operating sequence of VCB must be O-0.3Sec-CO-3 Mins-CO(v)Protection CT shall be minimum 40/1A ,2.5VA ,5P10. - 3 Nos 75 (vi)All modules of the RMU shall be suitable for cable termination of 3C x 300 sq.mm Al XLPE Cable, incoming cable termination is included within the scope of work - 1 SetTRANSFORMER315 KVA 11KV/433V DYN-11 Oil type, hermetically sealed energy efficiency level-2 transformer (BEE Star Rated-2) with corrugated wall, without conservator, type of design & Top Bushings for HT & LT with Off load tap switch of rating +5% to -5% @2.5%. Temp Rise - Oil/Winding 40/45 Deg cel. Losses (As per IS-1180 amended up to date)Max Losses @ 50% Load 955W and Max Losses @ 100% Load 2750 KW and Impedance of 4.5% (Subject to IS Tolerance (as per IS1180-2014) The transformer shall be conforming to IS: 2026 and IS: 1180(part-I). amended up to date. (i)01 No. Winding Temperature Indicator with Alarm and trip Contact.LT PANELLVS PANEL 500 AMPS 4 pole Aluminium BUSBAR (100% FOR PHASES AND 100% FOR NEUTRAL) - CURRENT DENSITY OF Aluminum as 1 A/sq.mm. ; LT panel made up of 1.5/2 mm thick CRCA sheet INCOMER CUM OUTGOINGS FROM TRANSFORMER(i)500 Amps 433V 4P 50Hz 50KA Fixed Manual Type Air Circuit Breaker (ACB)(ii) Multifunction meter with Modbus RS485 port & class 0.5 accuracy with Suitable CT. - 1 set 76 (iii)Hard wiring from each equipment inside CSS for scada connectivity (monitoring & control)to be brought to one set of TBs and a space for FRTU to be given. Supply of FRTU is not in scope. (iv)All Civil works such as PCC/RCC foundation, Plateform, Filling trench and pedestal etc as per CSS manufacturers recomandation are included in scope of work.OUTDOOR ENCLOSUREOutdoor type encloser of 1.5 mm (For non load bearing members) & 2.0 mm (For load bearing members) thickness having modular construction of Galvanised Sheet Steel in suitable design for better heat dissipation and providing robust. 77 construction. The Enclosure shall have IP54 degree of protection for HT & LT switchgear compartment & IP 23 degree of protection for transformer compartment. The enclosure exterior shall be painted with epoxy based powder paint (colour RAL 7032). Each compartment will be provided with the door and pad locking arrangement. The design of the enclosure should be type tested for suitablly handling any arcing inside the compartment for providing better safety to the operator. The compartment illumination lamp with door operated switch shall be provided for each compartment.Vacuum Interrupter,RMU,LT Switchgear, Multifunction meterand CSS Enciosure shall be of same make to ensure life cycle optimization. 78 Supply, installation, testing & commissioning of package type/unitised 11kV / 433 V Outdoor sub-station , (CSS) 400KVA made from G. I. enclosure complete as required conforming to IEC 62271-202 only and relevant IS specifications including K-10 Temperature Class as applicable for the rating, Internal Arc of 21 KA/1 Sec. IAC AB on 1:2:4 (1 cement :2 cores and : 4 Graded stone aggrregate of 40 mm nominal size) PCC foundation of suitable size extending 500 mm all around the outdoor enclosure and 1000 mm height (above ground level) complete with suitable sizes of GI Pipes for incoming/outgoing cables/earthing strips etc. and consisting of following complete as required. Angle iron frame of size 40x40x5mm NS all along the corner of the foundation CSS shall be from OEMs only . Licensed System Integrators of approved OEM are not allowed to supply.Package substation will have the following equipment :-HT SWITCHGEAR11kV 630Amps 21KA/3 sec. Non-Extensible Ring Main Unit Compact switchgear consisting of1 no. fixed motorized Vacuum Circuit Breaker Moduleand 2 nos. fixed morotized Load break switch module in SF6 insulated stainless steel enclosure with series trip, self powered microprocessor based numerical over current and earth fault relay protection. HT RMU shall preferably have site replaceable bushings to have very less downtime in the event of bushing breakage and restoration can be done immediately without sending the 79 RMU to OEM Works. Interconnection between HT Switchgear and primary of transformer shall be done through 1C x 3R x 95 sq.mm Aluminium XLPE cable. - 1 No.Vacuum Interrupter,RMU,LT Switchgear and CSS Enciosure shall be of same make to ensure life cycle optimization.(i)Microprocessor based IDMT Relay for Circuit Breakers - Self Powered along with series trip coil (Modbus RS485 complaint)(ii)Capacitive voltage indication fixed type system with LED for all feeder and FPI in all load break switch feeder.(iii)SF6 Gas pressure indicator.(iv)Operating sequence of VCB must be O-0.3Sec-CO-3 Mins-CO(v)Protection CT shall be minimum 40/1A ,2.5VA ,5P10. - 3 Nos.(vi)All modules of the RMU shall be suitable for cable termination of 3C x 300 sq.mm Al XLPE Cable, incoming cable termination is included within the scope of work - 1 Set 80 TRANSFORMER400 KVA 11KV/433V DYN-11 Oil type, hermetically sealed energy efficiency level-2 transformer (BEE Star Rated-2) with corrugated wall, without conservator, type of design & Top Bushings for HT & LT with Off load tap switch of rating +5% to -5% @2.5%. Temp Rise - Oil/Winding 40/45 Deg cel. Losses (As per IS-1180 amended up to date)Max Losses @ 50% Load 1150W and Max Losses @ 100% Load 3330 KW and Impedance of 4.5% (Subject to IS Tolerance (as per IS1180-2014) The transformer shall be confirming to IS: 2026 and IS: 1180(part-I). amended up to date. (i)01 No. Winding Temperature Indicator with Alarm and trip Contact.LT PANELLVS PANEL 630 AMPS 4 pole Aluminium BUSBAR (100% FOR PHASES AND 100% FOR NEUTRAL) - CURRENT DENSITY OF Aluminum as 1 A/sq.mm. ; LT panel made up of 1.5/2 mm thick CRCA sheet INCOMER CUM OUTGOINGS FROM TRANSFORMER(i)630 Amps 433V 4P 50Hz 50KA Fixed Manual Type Air Circuit Breaker (ACB) (ii) Multifunction meter with Modbus RS485 port & class 0.5 accuracy with Suitable CT. - 1 set 81 (iii)Hard wiring from each equipment inside CSS for scada connectivity (monitoring & control)to be brought to one set of TBs and a space for FRTU to be given. Supply of FRTU is not in scope. (iv)All Civil works such as PCC/RCC foundation, Plateform, Filling trench and pedestal etc as per CSS manufacturers recomandation are included in scope of work.OUTDOOR ENCLOSUREOutdoor type encloser of 1.5 mm (For non load bearing members) & 2.0 mm (For load bearing members) thickness having modular construction of Galvanised Sheet Steel in suitable design for better heat dissipation and providing robustconstruction. The Enclosure shall have IP54 degree of protection for HT & LT switchgear compartment & IP 23 degree of protection for transformer compartment. The enclosure exterior shall be painted with epoxy based powder paint (colour RAL 7032). Each compartment will be provided with the door and pad locking arrangement. The design of the enclosure should be type tested for suitablly handling any arcing inside the compartment for providing better safety to the operator. The compartment illumination lamp with door operated switch shall be provided for each compartment.Vacuum Interrupter,RMU,LT Switchgear, Multifunction meterand CSS Enciosure shall be of same make to ensure life cycle optimization. 82 Supply, installations, testing and commissioning factory made out door cubical typeLT panel board dust and verminproof , free standing, floor mounting type mounted on and incluidng1:3:6 PCC foundation as requried at site and of fabricated by 3.0mm thick CRCA Sheet over MS 50 X 50 x 6 mm thick angle iron frameof requriedtype for support with double door both sides open type with necessarylockingarrangement with sloppedroof on top duly paintedwith two coatsof powder coated semense gray paint complete and having separatedoors inside for accomodatingall incomming / outgoing feeders of suitable sizes all as specified and directedby Engr-in- Charge(Panel 1 - Near mains transformer GTC Area):- 83 INCOMING :-(i) S&F ACB 4 Pole 630 amps ,415 Volt electrical drawout type of breaking capacity not less than50 KA (Ics=100 % of Icu) with Adjustable TM Range (Optium 2.0) - 01 Nos Incommer.(ii) Aluminium electrolite Busbar 750 Amps current rating duly sleev insulated for set of 3 phase, 4 wire system and branch connection of suitable size of outgoing current rating of MCB/MCCBsOUTGOING:-(i) S&F MCCB 4 Pole 315 amps ,415 Volt of breaking capacity not less than16 KA (Ics=100 % of Icu) with Adjustable TM Range (Optium 2.0) - 01 No (for LT distribution panels of block )(ii) S&F MCCB 4 Pole 200 amps ,415 Volt of breaking capacity not less than16 KA (Ics=100 % of Icu) with adjustable thermal Setting (Optium 2.0) -02 Nos(for LTP Pump Motor, lift, fire fighting, stree light etc + spare).(iii)Digital Ammeter 0-500 A with selector switch & CTs of suitable capacity - 01 set.(ivDigital volt meter 0-400 V with selector switch - 01 No.(v)LED Indicating Lamps R,Y,B - 01 Set of three 84 Supply, installations, testing and commissioning factory made out door cubical typeLT panel board dust and verminproof , free standing, floor mounting type mounted on and incluidng1:3:6 PCC foundation as requried at site and of fabricated by 3.0mm thick CRCA Sheet over MS 50 X 50 x 6 mm thick angle iron frameof requriedtype for support with double door both sides open type with necessarylockingarrangement with sloppedroof on top duly paintedwith two coatsof powder coated semense gray paint complete and having separatedoors inside for accomodatingall incomming / outgoing feeders of suitable sizes all as specified and directedby Engr-in- Charge:- (Panel 2 - Near Chambal Vihar Main Tfr Panel):-INCOMING :-(a) S&F MCCB 4 Pole 500 amps ,415 Volt of breaking capacity not less than36 KA (Ics=100 % of Icu) with Adjustable TM Range (Optium 2.0) - 01 Nos Incommer.(b) Aluminium electrolite Busbar 600 Amps current rating duly sleev insulated for set of 3 phase, 4 wire system and branch connection of suitable size of outgoing current rating of MCB/MCCBs 85 OUTGOING:-(i) S&F MCCB 4 Pole 250 amps ,415 Volt of breaking capacity not less than25 KA (Ics=100 % of Icu) with Adjustable TM Range (Optium 2.0) - 01 No (for LT distribution panels of blocks)(ii) S&F MCCB 4 Pole 160 amps ,415 Volt of breaking capacity not less than25 KA (Ics=100 % of Icu) with adjustable thermal Setting (Optium 2.0) -02 Nos(for LTP Pump Motor, lift, fire fighting, stree light etc + spare).(iii)Street light timer using Power contactor 32 Amps, (1-NO) 3 pole, 415Volt, DIN Type digital programable time switch 230V AC, Auto/Manual selector switch, MCB 4 pole 25 Amps C-range, ON/OFF indicator all prewired and making provision for fixing outgoing cables- 01 Set complete.(iv)Digital Ammeter 0-500 A with selector switch & CTs of suitable capacity - 01 set.(v)Digital volt meter 0-400 V with selector switch - 01 No.(vi)LED Indicating Lamps R,Y,B - 01 Set of three 86 Supply, installations, testing and commissioning factory made out door cubical typeLT panel board dust and verminproof , free standing, floor mounting type mounted on and incluidng1:3:6 PCC foundation as requried at site and of fabricated by 3.0mm thick CRCA Sheet over MS 50 X 50 x 6 mm thick angle iron frameof requriedtype for support with double door both sides open type with necessarylockingarrangement with sloppedroof on top duly paintedwith two coatsof powder coated semense gray paint complete and having separatedoors inside for accomodatingall incomming / outgoing feeders of suitable sizes all as specified and directedby Engr-in- Charge:- (Panel 1A - LT PANEL FOR 3 X BLOCKS GTC):-INCOMING :-(i) S&F MCCB 4 Pole 315 amps ,415 Volt of breaking capacity not less than36 KA (Ics=100 % of Icu) with Adjustable TM Range (Optium 2.0) - 01 Nos Incommer.(ii) Aluminium electrolite Busbar 400 Amps current rating duly sleev insulated for set of 3 phase, 4 wire system and branch connection of suitable size of outgoing current rating of MCB/MCCBs 87 OUTGOING:-(i) S&F MCCB 4 Pole 125 amps ,415 Volt of breaking capacity not less than25 KA (Ics=100 % of Icu) with Adjustable TM Range (Optium 2.0) - 04 No (for 3 X Blocks+spare)(ii) Digital Ammeter 0-500 A with selector switch & CTs of suitable capacity - 01 set.(iii)Digital volt meter 0-400 V with selector switch - 01 No.(iv)LED Indicating Lamps R,Y,B - 01 Set of three 88 Supply, installations, testing and commissioning factory made out door cubical typeLT panel board dust and verminproof , free standing, floor mounting type mounted on and incluidng1:3:6 PCC foundation as requried at site and of fabricated by 3.0mm thick CRCA Sheet over MS 50 X 50 x 6 mm thick angle iron frameof requriedtype for support with double door both sides open type with necessarylockingarrangement with sloppedroof on top duly paintedwith two coatsof powder coated semense gray paint complete and having separatedoors inside for accomodatingall incomming / outgoing feeders of suitable sizes all as specified and directedby Engr-in- Charge:- (Panel 2A - LT PANEL FOR 2 X BLOCKS CHAMBAL VIHAR):-INCOMING :-(i) S&F MCCB 4 Pole 250 amps ,415 Volt of breaking capacity not less than36 KA (Ics=100 % of Icu) with Adjustable TM Range (Optium 2.0) - 01 Nos Incommer.(ii) Aluminium electrolite Busbar 400 Amps current rating duly sleev insulated for set of 3 phase, 4 wire system and branch connection of suitable size of outgoing current rating of MCB/MCCBs 89 OUTGOING:-(i) S&F MCCB 4 Pole 125 amps ,415 Volt of breaking capacity not less than25 KA (Ics=100 % of Icu) with Adjustable TM Range (Optium 2.0) - 03 No (for 3 X Blocks+spare)(ii) Digital Ammeter 0-500 A with selector switch & CTs of suitable capacity - 01 set.(iii)Digital volt meter 0-400 V with selector switch - 01 No.(iv)LED Indicating Lamps R,Y,B - 01 Set of three 90 Supply, installations, testing and commissioning factory made out door cubical typeLT panel board dust and verminproof , free standing, floor mounting type mounted on and incluidng1:3:6 PCC foundation as requried at site and of fabricated by 3.0mm thick CRCA Sheet over MS 50 X 50 x 6 mm thick angle iron frameof requriedtype for support with double door both sides open type with necessarylockingarrangement with sloppedroof on top duly paintedwith two coatsof powder coated semense gray paint complete and having separatedoors inside for accomodatingall incomming / outgoing feeders of suitable sizes all as specified and directedby Engr-in- Charge:- (Panel 1B & 2B):-INCOMING :-(i) S&F MCCB 4 Pole 200 amps ,415 Volt of breaking capacity not less than25 KA (Ics=100 % of Icu) with Adjustable TM Range-01 No incoming.(ii) Aluminium Electrolite Busbar 300Amps current rating duly sleev insulated for set of 3 phase, 4 wire system and branch connection of suitable size of outgoing current rating of MCB/MCCBs-01Set 91 OUTGOING:-(i) MCCB 4 pole 63 Amp, 415 V, 16 KA, C-series. - 01 Nos (for PH Panel)(ii) MCCB 4 pole 40 Amp, 415 V, 16 KA, C-series- 02 Nos (sewage PH +spare).(iii) MCB TPN 25Amp, 230 V, 10 KA, C-series - 07 Nos (Lifts+fire fighting+Street lights)(iv)Street light timer using Power contactor 25 Amps, (1-NO) 3 pole, 415Volt, DIN Type digital programable time switch 230V AC, Auto/Manual selector switch, MCB 4 pole 25 Amps C-range, ON/OFF indicator all prewired and making provision for fixing outgoing cables- 01 Set complete.(v) Digital Ammeter 0-150 A with selector switch & CTs of suitable capacity - 01 set.(vi) Digital volt meter 0-500 V with selector switch - 01 No. (vii) On load Change over switch 4 pole of current raring 63-100 A (open execution type) - 01 No.(viii)LED Indicating Lamps R,Y,B - 01 Set of three 92 Supply, installations, testing and commissioning factory made out door cubical typeLT panel board dust and verminproof , free standing, floor mounting type mounted on and incluidng1:3:6 PCC foundation as requried at site and of fabricated by 3.0mm thick CRCA Sheet over MS 50 X 50 x 6 mm thick angle iron frameof requriedtype for support with double door both sides open type with necessarylockingarrangement with sloppedroof on top duly paintedwith two coatsof powder coated semense gray paint complete and having separatedoors inside for accomodatingall incomming / outgoing feeders of suitable sizes all as specified and directedby Engr-in- Charge:- (Panel D - DOE Area):-INCOMING :-(i) S&F MCCB 4 Pole 100 amps ,415 Volt of breaking capacity not less than16 KA (Ics=100 % of Icu) with adjustable thermal Setting (Optium 2.0)-01 No incoming.(ii) Aluminium Electrolite Busbar 150 Amps current rating duly sleev insulated for set of 3 phase, 4 wire system and branch connection of suitable size of outgoing current rating of MCB/MCCBs-01Set 93 OUTGOING:-(i) MCCB 4 pole 63 Amp, 415 V, 16 KA, C-series - 02 Nos (for Bldg + Spare)(ii) MCB SPN 10 Amp, 415 V, 10 KA, C-series - 02 Nos (Garages + Spare).(iii) MCB SPN 10 Amp, 230 V, 10 KA, C-series - 02 Nos (Security light + Spare)(iv) Digital Ammeter 0-150 A with selector switch & CTs of suitable capacity - 01 set.(v) Digital volt meter 0-500 V with selector switch - 01 No.(vi)LED Indicating Lamps R,Y,B - 01 Set of three 94 M&L for factory made busbar box 750 Amps rated Aluminium busbar, 3 phase, 4 wire, 415 Volt of size not less than 300mm x 200mm x 100mm, fabricated using 1.6mm MS sheet, duly painted with smoke gray powder coated over a coat of red oxide primer suitable for fixing on wal by using wall fastners 10mm dia and making necessary incomming and outgoing connection of electric cables using aluminium lugs etc complete all as specified and diected. 95 M&L for factory made busbar box 600 Amps rated Aluminium busbar, 1 phase, 245 Volt, size not less than 200mm x 150mm x 100mm, fabricated using 1.6mm MS sheet, duly painted with smoke gray powder coated over a coat of red oxide primer suitable for fixing on wall by using wall fastners 10mm dia and making necessary incomming and outgoing connection of electric cables using aluminium lugs etc complete all as specified and diected. 96 Supply and fixing poly carbonatejunction box , weather and vermin proof of size 250X250X160 including provn of 4 Nos aluminium strip 25x3.15 mm size bus bar single phase and neutral suitabely mounted on bus bar insulators ,including one No. MCB SP 6 Amps for light control,drilling of holes.Provn of suitable size of GI nuts, bolts, double washer and FI clamps ofsuitable sizefor taking connections and fixing on LT steel tubular poles complete with locking arrangementcomplete all as specified and directed. 97 Supply and connecting three core cord flexible wire, copper conductor multistranded, PVC insulated and overall PVC sheathed of size 1.5Sqmm 1100 Volt , draw through LT steel tubular polesfor connection to street light from junction boxetc complete all as specified & directed. 98 S&F for Cable route indicator, duly engraved with LT CABLE 1100 VOLT on cast iron round plate 150 mm dia with provision of 500 mm long (minimum) single leg/stand of flat iron 40 x 5 mm, welded/riveted on back side of plate, fixed and grouted in position with PCC 1:3:6 type C-1, block of suitable size etc complete all as specified & directed. 99 M&L for Precast PCC (1:2:4) type B-1 cable path indicators of size 300x100x500mm rounded top having engraved in capital letters HT Cable embedded in position in PCC(1:3:6) Type C-1, using necessary formwork and including provision of two coats of cement base paint on exposed concrete surface and writing HT Cable in black synthetic enamel paint etc complete all as specified & directed. 100 M&L fordecorative LED post top lantern (PTL) luminior with die cast aluminium spigot, spun aluminium powder coated top cover clear/opal acralic difusser LED light fitting of 25 watts including LED lamp etc complete all as specified & directed. 101 M& L for shifting of 33 KV HT cable to a safe distance from proposed building, supply, laying, testing & commisioning of 33 KV cable in replacement with new as per estimate provided by State electricity deptetc etc complete all as specified & directed. 102 FIRE FIGHTINGS&F forAutomatic air release valve 50mm dia suitable for domestic water with 25mm gun metal stop valveetc complete all as specified & directed. 103 S&F forbranch pipe with nozzle of 20mm dia for hose reel conforming to IS 8090etc complete all as specified and directed. 104 S&F forfix Valve, stop, screwed, 25 mmdia pipeetc complete all as specified and directed. 105 S&F for6 kg capacity Multipurpose dry chemical powder (ABC) type(IS-15683) fire extinguishers consisting of welded MS cylindrical body fabricated from 1.6 mm MS sheet internally protected with anticorrosive treatment and hydraucally tested. Extinguisher externally painted with red enamel and fixed to wall with bracket complete with initial filled/charged .etc complete all as specified and directed. 106 S&F forCO2 type fire extinguisher of 3 Kgs capacity with steel cylinder with a discharge valve and confirming to IS : 15683.Extinguisher shall be painted with red enamel apint and fixed to wall with bracket etc complete all as specified and directed. 107 S&F for9 Ltr capacity Foam type(IS-15683) fire extinguishers consisting of welded MS cylindrical body fabricated from 1.6 mm MS sheet internally protected with anticorrosive treatment and hydraucally tested. Extinguisher externally painted with red enamel and fixed to wall with bracket complete with initial filled/chargedetc complete all as specified and directed. 108 S&F fortesting of Star-Delta starter Panel for fire fighting pump motor etc complete all as specified and directed. 109 Supply, installation, testing & commissioning ofFIRE SIGNAGES for indication/information of fire exit, alarm panel, fire extinguishers fire axe, hose reel, hydrents, lifts of size 300mmx100mm etc complete all as specified and directed. 110 DG SETSSupply, installation, commissioning and testing complete of Manufacturer of OEM (Original Eqpt Manufacturer) manufactured and tested static Diesel Engine driven generating set capable of delivering 180 KVA continuous rating, (10% overload for 1 hour in 12 hours of operation), 415 volts (AC 3 phase, 4 wire system of supply), 50 Hz at power factor 0.8 minimum. The DG set shall consist of a diesel engine coupled directly to a matching alternator, and mounted on Dunlop metallastik foundation pads on a common base frame and thereafter installed in the CPCB approved acoustic enclosure complete with control panel standardised by manufacturer, fuel tank with mounting arrangement and inlet, outlet, return oil arrangement, flexible exhaust pipe complete all as specified and directed and shall include comprise of the following :- 111 (A) Engine (prime mover) : Diesel engine 1500 RPM, of suitable HP as recommended by manufacturer, water cooled, turbocharged, 12 volts electric battery start, complete with fly wheel and torsional vibration damper, rediator and all standard fittings/fixtures as per standard manufacturing practices and including suitable instrument panel with RPM meter, lub oil temp and pressure gauge, water temp gauge and frequency meter (digital type), battery charging ammeter and fuses, and also including self starter (12V), battery charging alternator, fuel tank etc and complete with HWT and LLOP alarm and shut down safeties complete with first fill of Lub oil and Coolent. (B) Alternator : AC alternator, brushless, 415V AC 50 Hz, 3 phase, 4 wire type, rated for continuous output of 63 KVA, PF 0.8 (lag), 1500 RPM insulation class H; enclosure SPDP (IP 22/23), self excited & self regulated with AVR for + 1% voltage regulation, coupled directly/suitably to and to match the above engine and conforming to BS 5000/IS 4722. 112 (C) Dunlop Metallastik anti-vibration of pads for mounting engine - alternator assembly on the base frame/plate.(D) Base plate : Made out of structural steel as per manufacturers recommended design/specifications.(E) Enclosure : Provision of an integral type, approved/certified acoustic enclosure as per latest CPCB norms, for the DG set to restrict the noise level to 75 DB (A) at one metre and ensure that temperature rise within the canopy shall not exceed 5 - 7 degree celsius, It shall be made of 16 SWG CRCA MS sheet with powder-coated finish on outside and high quality noise absorbent and fire retardant grade acuoustic insulation material duly provided with EPDN gasket lining. There shall be four hinged doors out of which one shall be with a glass window.(i)Silencer : Absorption type, non-resistance, residential.(ii) Internal wiring with PVC copper conductor cables, IS 694 marked, FRLS in conduit and suitable light fittings.(iii)Fuel tank to be provided as per OEM specificaton.(iv)Safeties for high enclosure temperature and emergency shut-down from outside.(v) 1No 12V of suitable AH lead acid batteries and adequate size copper conductor cable leads, housed on & including suitable size MS angle iron frame and necessary clamps, nuts, bolts, washers all as required & as per manufacturer design/specifications.(F) Control panel : Control panel made out of 14 gauge CRCA sheet, powder coated and shall consists of the following: - 113 (i) Ps 0500 Controller (ii) Aluminium Bus bars with suitable capacity incoming & outgoing terminals.(iii) Indicating lamps for load on and set running (iv) Instrument fuses duly wired and ferruled. (v) Circuit breaker(MCCB) of suitable rating with overload and short circuit protections. Note: To be mounted inside enclosure. (G) Automatic mains failure (AMF) control panel fabricated from CRCA sheet steel of thickness not less than 3.15 mm, suitable for outdoor installation (including CPRI type test certified), dust & vermin proof, protection class I P-54 suitable for 415 volts, 3 phase, 4 wire, 50 Hz, AC supply system with adequate layers of power coating floor mounting type with front opening, the AMF panel shall comprise the following indicating instruments & switches:- 114 AC voltmeter - 01NoVoltmeter selector switch OFF/RY/YB/BR - 01NoFrequency meter - 01NoAC voltmeter of suitable scale - 01NoAmmeter selector switch OFF/R/Y/B - 01NoCurrent transformers of suitable ratio - 01NoBattery charger consisting of - 01No(aa) Transformer / Rectifier unit (bb) DC ammeter /DC voltmeter(cc) Charging rate selector switch OFF/Trickle/BoostMains supply air break contactor, 3 pole of suitable raing - 01NoAlternator air break contactor, 3 pole of suitable rating and provided with a separate overload relay for overload protection - 01NoMains supply voltage monitor - 01NoSet of DC control relays and timers - 01NoSet of push buttons, START, STOP, ACKNOWLEDGE, RESET, MAINS BREAKER, CLOSE/TRIP, ALTERNATOR BREAKER CLOSE / TRIP - 01No 115 01 Set of indicating lamps for the following :-LOAD ON MAINS, LOAD ON SET, SET FAILS TO START, LOW OIL PRESSURE, HIGH TEMPERATURE ALARM, HIGH TEMPERATURE TRIP, ALTERNATOR OVERLOAD.Audio - alarm hooter - 01NoKWH meter - One Set of Bus bars - 01NoThe control cubicle will be furnished complete with the necessary control circuit fuses, etc. and will have provisions for making incoming and outgoing connections.KW meter - 01Noset of bus bar - 01NoThe control cubical will be furnished complete with the necessary control circuit fuse etc and will have provision for making incoming and outgoing connectionsOne - set of bus bar - 01NoThe control cubicle will be furnished complete with the necessary control circuit fuses, etc. and will have provisions for making incoming and outgoing connections.Note :(i) In case AMF panel included instead of Standard Control Panel, then Battery charging alternator with inbuilt regulator and battery charging ammeter should be deleted from engine specifications since Battery charger included under AMF Panel specifications. 116 (ii) Platform : PCC foundation /plinth/baseshall be provided as per drawing No: TD/2010/109, Sheet No 1/1.(iii) Tool kit, Operation and Maintenance catalogue, 1 year spare part list, overhauling manuals, guarantee card etc shall be provided as per manufacturer standard practices. 117 Supply, installation, commissioning and testing complete of Manufacturer of OEM (Original Eqpt Manufacturer) manufactured and tested static Diesel Engine driven generating set capable of delivering 125 KVA continuous rating, (10% overload for 1 hour in 12 hours of operation), 415 volts (AC 3 phase, 4 wire system of supply), 50 Hz at power factor 0.8 minimum. The DG set shall consist of a diesel engine coupled directly to a matching alternator, and mounted on Dunlop metallastik foundation pads on a common base frame and thereafter installed in the CPCB approved acoustic enclosure complete with control panel standardised by manufacturer, fuel tank with mounting arrangement and inlet, outlet, return oil arrangement, flexible exhaust pipe complete all as specified and directed and shall include comprise of the following :- 118 (A) Diesel engine 1500 RPM, of suitable HP as recommended by manufacturer, water cooled, turbocharged, 12 volts electric battery start, complete with fly wheel and torsional vibration damper, rediator and all standard fittings/fixtures as per standard manufacturing practices and including suitable instrument panel with RPM meter, lub oil temp and pressure gauge, water temp gauge and frequency meter (digital type), battery charging ammeter and fuses, and also including self starter (12V), battery charging alternator, fuel tank etc and complete with HWT and LLOP alarm and shut down safeties complete with first fill of Lub oil and Coolent. (B) Alternator : AC alternator, brushless, 415V AC 50 Hz, 3 phase, 4 wire type, rated for continuous output of 63 KVA, PF 0.8 (lag), 1500 RPM insulation class H; enclosure SPDP (IP 22/23), self excited & self regulated with AVR for + 1% voltage regulation, coupled directly/suitably to and to match the above engine and conforming to BS 5000/IS 4722. (C)Dunlop Metallastik anti-vibration of pads for mounting engine - alternator assembly on the base frame/plate. 119 (D) Base plate : Made out of structural steel as per manufacturers recommended design/specifications.(E) Enclosure : Provision of an integral type, approved/certified acoustic enclosure as per latest CPCB norms, for the DG set to restrict the noise level to 75 DB (A) at one metre and ensure that temperature rise within the canopy shall not exceed 5 - 7 degree celsius, It shall be made of 16 SWG CRCA MS sheet with powder-coated finish on outside and high quality noise absorbent and fire retardant grade acuoustic insulation material duly provided with EPDN gasket lining. There shall be four hinged doors out of which one shall be with a glass window.(i)Silencer : Absorption type, non-resistance, residential.(ii) Internal wiring with PVC copper conductor cables, IS 694 marked, FRLS in conduit and suitable light fittings.(iii)Fuel tank to be provided as per OEM specificaton.(iv)Safeties for high enclosure temperature and emergency shut-down from outside.(v) 1Nos 12V of suitable AH lead acid batteries and adequate size copper conductor cable leads, housed on & including suitable size MS angle iron frame and necessary clamps, nuts, bolts, washers all as required & as per manufacturer design/specifications. 120 (F) Control panel : Control panel made out of 14 gauge CRCA sheet, powder coated and shall consists of the following: - (i) Ps 0500 Controller (ii) Aluminium Bus bars with suitable capacity incoming & outgoing terminals.(iii) Indicating lamps for load on and set running(iv) Instrument fuses duly wired and ferruled. (v) Circuit breaker(MCCB) of suitable rating with overload and short circuit protections. Note: To be mounted inside enclosure. (G) Automatic mains failure (AMF) control panel fabricated from CRCA sheet steel of thickness not less than 3.15 mm, suitable for outdoor installation (including CPRI type test certified), dust & vermin proof, protection class I P-54 suitable for 415 volts, 3 phase, 4 wire, 50 Hz, AC supply system with adequate layers of power coating floor mounting type with front opening, the AMF panel shall comprise the following indicating instruments & switches:- AC voltmeter -01 NoVoltmeter selector switch OFF/RY/YB/BR - 01 No 121 Frequency meter - 01 NoAC voltmeter of suitable scale - 01 NoAmmeter selector switch OFF/R/Y/B - 01 NoCurrent transformers of suitable ratio - 01 NoBattery charger consisting of - 01 No(aa) Transformer / Rectifier unit (bb) DC ammeter /DC voltmeter(cc) Charging rate selector switch OFF/Trickle/BoostMains supply air break contactor, 3 pole of suitable raing - 01 NoAlternator air break contactor, 3 pole of suitable rating and provided with a separate overload relay for overload protection - 01 NoMains supply voltage monitor - 01 NoSet of DC control relays and timers - 01 NoSet of push buttons, START, STOP, ACKNOWLEDGE, RESET, MAINS BREAKER, CLOSE/TRIP, ALTERNATOR BREAKER CLOSE / TRIP - 01 No01 Set of indicating lamps for the following :-LOAD ON MAINS, LOAD ON SET, SET FAILS TO START, LOW OIL PRESSURE, HIGH TEMPERATURE ALARM, HIGH TEMPERATURE TRIP, ALTERNATOR OVERLOAD.Audio - alarm hooter - 01NoKWH meter - One Set of Bus bars - 01NoThe control cubicle will be furnished complete with the necessary control circuit fuses, etc. and will have provisions for making incoming and outgoing connections. 122 KW meter - 01Noset of bus bar - 01NoThe control cubical will be furnished complete with the necessary control circuit fuse etc and will have provision for making incoming and outgoing connectionsOne - set of bus bar - 01NoThe control cubicle will be furnished complete with the necessary control circuit fuses, etc. and will have provisions for making incoming and outgoing connections.Note :(i) In case AMF panel included instead of Standard Control Panel, then Battery charging alternator with inbuilt regulator and battery charging ammeter should be deleted from engine specifications since Battery charger included under AMF Panel specifications. 123 (ii) Platform : PCC foundation /plinth/baseshall be provided as per drawing No: TD/2010/109, Sheet No 1/1.(iii) Tool kit, Operation and Maintenance catalogue, 1 year spare part list, overhauling manuals, guarantee card etc shall be provided as per manufacturer standard practices. 124 Supply, installations, testing of electric chimney of size 60cm havingsuction capacity of 1200 cum per hour with filterless technology sealed motor and insulationfor oil deposit and water vapour alongwith self autoclean feature after 30 cycles of operation and minimum 5 year warranty etc etc complete all as specified and directed.
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 5
31.
Public Administrative Department #11278159 Technical Bid
Tender for Site Clearance: , Surface Dressing Of The Ground Including Removing Vegetation And In Equalities Not Exceeding 15 Cm Deep And Disposal Of Rubbish, Lead Up To 50 M And Lift Up To 1.5 M. All Kinds Of Soil . , Earth Work: , Earth Work In Excavation By Mechanical Means (Hydraulic Wxcavator) Manual ,Eans In Foundation Trenches Ordrains Including Dressing Of Sides And Ramming Ofbottoms, Lift Uoto 1.5M Including Getting Out The Exavated Soil Anddisposal Of Surplus Excavated Soil As Directed Within A Lead Of 50M. , Antitermite Treatment: , Supplying Chemical Emulsion In Sealed Containers Including Delivery As Specified.Chlorpyriphos/Lindane Emulsifiable Concentrate Of 20%. , Back Filling Of Earth: , Filling Available Excavated Earth In Trenches Plinth Sides Of Foundation Etc.In Layer Not Exceeding 20 Cm In Depth Consolidating Each Deposited Layer By Ramming And Watering Lead Upto 50M And Lift Upto 1.5M. , Filling With Available Fly Ash And Earth In Trenches Bor Embankment In Layer With Intermediate Layer Of Compacted Earth After Every Four Layers Of Compacted Depth Of Fly Ash Sides & Top Layer Of Filling Shall Be Dine With Earth Having Total Minimum Compacted Thickness 30 Cm Or As Decided By Engineer -In- Charge Including Compacting Each Layer By Rolling Ramming And Watering All Complete As Per Drawing And Direction Of Enginner-In-Charge. , Supply & Filling In Plinth With Sand Under Floors Including Watering Ramming Consolidating And Dressing Complete. , Plain Cement Concrete , Providing And Laying In Position Cement Concrete 1:4:8 Aggregated Excluding The Cost Of Centering And Shuttering-All Work Upto Plinth Level. , Reinforced Cement Concrete Work , Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete Excluding The Cost Of Centring Shuttering Finishing And Reinforced-All Work Upto Plinth Level 1:1.5:3 All Works Upto Plinth Level. . , Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete Excluding The Cost Of Centring Shuttering Finishing And Reinforced-All Work Upto Plinth Level 1:1.5:3 All Works Above Plinth Level Upto Floor V Level. , Plinth Protection , Making Plinth Protection 50Mm Thick Of Cement Concrete 1:3:6 Over 75Mm Thick Bed Of Dry Brick Ballast 40 Mm Nominal Size, Well Rammed And Consolidated And Grouted With Fine Sand, Including Necessary Excavation Leveling & Dressing & Finishing The Top Smooth. , Shuttering & Centering , Centering Shuttering Including Strutting Propping Etc. And Removal Of From Work Foundations ,Footing ,Bases Of Column Etc. For Mass Concrete. , Centering Shuttering Including Strutting Propping Etc. And Removal Of From Work Columns ,Pillars,Piers, Abutments, Posts And Struts. , Centering Shuttering Including Strutting Propping Etc. And Removal Of From Work Suspended Floors ,Roofs,Landings, Balconies And Access Platform. , Centering Shuttering Including Strutting Propping Etc. And Removal Of From Work Lintels, Beams ,Plinth Beams,Girders, Bressumers And Cantilevers. , Reinforcement Of Steel , Reinforcement For Reinforced Cement Concrete Work Including Straighting Cutting,Bending,Placing In Position And Bending All Complete Themro-Mechanically Treated Bars. , Brick Work , 230Th Brick Work With Comman Burnt Clay F.P.S (Non Modular) Brick Of Class Designation 75 In Foundation & Plinth In Cement Mortar 1:6 , Brick Work With F.P.S Bricks Of Class 75 In Super Structure Above Plinth Level Up To Floor Five Level In All Shapes And Sizes In Cement Mortar 1:6 , Half Brick Masonry With F.P.S Bricks Of Class Designation 75 In Super Structure Above Plinth Level Up To Floor Five Level In Cement Mortar 1:4 , Door, Window, Ventilator , Providing And Fixing Two And Half Track Three Panels Sliding Window With Two Glazed & One Wire Mesh Panels With Aluminium Channel For Roller Track, Wool Pile, Nylon Rollers With Ss 304 Body. Using R2 Series With Frame (65 Mm & Above) X (40 Mm & Above) & Glazed Sash (25 Mm & Above) X (50 Mm & Above) & Fly Screen Sash (18 Mm & Above)X (40 Mm & Above) With Zinc Alloy (Zamak) Powder Coated Touch Locks With Hook (Height Upto 1.2 Metre). , Providing And Fixing Two Track Two Panels Sliding Door With Aluminium Channel For Roller Track, Wool Pile, Zinc Alloy (Zamak) Powder Coated Handle On Every Panel Along With Multi-Point Locking System, Adjustable Nylon Rollers With Ss 304 Body. Using R3 Series With Frame (55 Mm & Above) X (40 Mm & Above) & Sash (30 Mm & Above) X (7 4 Mm & Above). (Height Upto 2.5 Metre). , Providing And Fixing Fixed Window I Ventilator With Mullion I Transom. Using R1 Series With Frame (33 Mm & Above ) X (35 Mm & Above) & Mullion (33 Mm & Above) X (50 Mm & Above). (Height Upto 0.90 Metre) , Providing And Fixing 37 Mm Thick Factory Made Pvc Door Shutter, Styles And Rails Made Of Pvc Hollow Extruded Printed And Laminated Section Having Overall Dimension 115 Mm X 37 Mm With Wall Thickness 2 Mm (± 0.2 Mm) With Inbuilt Beading On One Side, The Styles And Rails Mitred Cut And Joint At Corners By Inserting 2 Nos Pvc Profile Reinforcement Of Size 75 Mm X 200 Mm Long With Cross Section Size Of 28 Mm X 30 Mm Having Wall Thickness 2 Mm (± 0.2 Mm). Styles, Rails And Reinforcements To Be Fusion Welded Together. Only Hinge Side Vertical Style To Be Reinforced With Pvc Profile Reinforcement In Full Length , Railing Work , Steel Work Welded In Built Up Sections/ Framed Work, Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer Using Structural Steel Etc. As Required. In Gratings, Frames, Guard Bar, Ladder, Railings, Brackets, Gates And Similar Works , Providing And Fixing Hand Rail Of Approved Size By Welding Etc. To Stee Ladder Railing, Balcony Railing, Staircase Railing And Similar Works, Including Applying Priming Coat Of Approved Steel Primer. M.S. Tube , Spiral Staircase (M.S) , Steel Work Welded In Built Up Sections/ Framed Work, Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer Using Structural Steel Etc. As Required. In Gratings, Frames, Guard Bar, Ladder, Railings, Brackets, Gates And Similar Works , Providing And Fixing Hand Rail Of Approved Size By Welding Etc. To Stee Ladder Railing, Balcony Railing, Staircase Railing And Similar Works, Including Applying Priming Coat Of Approved Steel Primer. M.S. Tube , Plaster & Finishing Work , 12Mm Thick Plaster On The Plain In Side Of Mix 1:6 Mortar. , 15Mm Cement Plaster On The Rough Side Of Single Or Half Brick Wall Of Mix. , 6Mm Thick Cement Plaster Of Ceiling Of Mix 1:6 Mortar. (Dsr 2023 -13.16.1) , Distempering With Oil Bound Washable Distemper Of Approved Brand And Manufacture To Give An Even Shade: New Work Over And Including Water Thinnable Priming Coat With Cement Prime. , Providing And Applying White Cement Based Putty Of Average Thickness 1Mm Of Approved Brand And Manufacturer,Over The Plastered Wall Surface To Prepare The Surface Even And Smooth Complete. , Finishing Walls With Acrylic Smooth Exterior Paint Of Required Shade New Work , Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture Of Required Colour To Give An Even Shade: Two Or Nore Coats On New Work Over An Under Coat Of Suitable Shade With Oridinary Paint Of Approved Brand And Manufacture. , Flooring Work , Providing And Laying Verified Floor Tiles In Different Sizes With Water Absorption Less Than 0.08% And Conforming To Is:15622, Of Approved Make In All Colours And Shades Laid On 20Mm Thick Cement Mortar 1:4 ,Jointing With Grey Cement Slurry @3.3Kg/Sq.M Including Groutibg The Joints With White Cement And Matching Pigments Etc. Complete Size Of Tile 600 X 600 Mm. , Providing And Fixing 1St Qaulity Ceramic Glazes Floor Tiles Conforming To Is:15622 Of Approved Make In All Colours Shades Except Burgundy Bottle Green Black Of Any Size As Approved By Engineer-In-Charge In Skirting,Risers Of Steps And Dados Over 12Mm Thick Bed Of Cement Mortar 1:3 And Jointing With Grey Cement Slurry @3.3Kg Per Sqm Including Pointing In White Cement Mixed With Pigment Of Matching Shade Complete. , Providing And Fixing 1St Qaulity Ceramic Glazes Wall Tiles Conforming To Is:15622 Of Approved Make In All Colours Shades Except Burgundy Bottle Green Black Of Any Size As Approved By Engineer-In-Charge In Skirting,Risers Of Steps And Dados Over 12Mm Thick Bed Of Cement Mortar 1:3 And Jointing With Grey Cement Slurry @3.3Kg Per Sqm Including Pointing In White Cement Mixed With Pigment Of Matching Shade Complete. , Grouting The Joints Of Flooring Tiles Having Joints Of 3 Mm Width, Using Epoxy Grout Mix Of 0.70 Kg Of Organic Coated Filler Of Desired Shade (0.10 Kg Of Hardener And 0.20 Kg Of Resin Per Kg), Including Filling I Grouting And Finishing Complete As Per Direction Of Engineer-In-Charge. . , Providing And Laying Tactile Tile (For Vision Impaired Persons As Per Standards) Of Size 300X300x9.8 Mm Having With Water Absorption Less Than 0.5% And Conforming To Is:15622 Of Approved Make In All Colours And Shades In For Outdoor Floors Such As Footpath, Court Yard, Multi Modals Location Etc., Laid On 20 Mm Thick Base Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) In All Shapes & Patterns Including Grouting The Joints With White Cement Mixed With Matching Pigments Etc. Complete As Per Direction Of Engineer-In-Charge. , False Ceiling , Providing And Fixing False Ceiling At All Heights Including Providing And Fixing Of Frame Work Made Of Special Sections, Power Pressed From M.S Sheets And Galvanized With Zinc Coating Of 120 Gms/Sqm (Both Side Nclusive) As Per Is : 277 And Consisting Of Angle Cleats Of Size 25 Mm Wide X 1.6 Mm Thick With Flanges Of 27 Mm And 37Mm, At 1200 Mm Centre To Centre, One Flange Fixed To The Ceiling With Dash Fastener 12.5 Mm Dia X 50 Mm Long With 6 Mm Dia Bolts, Other Flange Of Cleat Fixed To The Angle Hangers Of 25X1 Ox0.50 Mm Of Required Length With Nuts & Bolts Of Required Size And Other End Of Angle Hanger Fixed With Intermediate G.I. Channels 45X15x0.9 Mm Running At The Spacing Of 1200 Mm Centre To Centre. , Water & Damp Proofing , Providing And Laying Water Proofing Treatment On Roofs Of Slabs By Applying Cement Slurry Mixed With Water Proofing Cement Compound Consisting Of Applying. ( , Drainage & Water Supply Works , Providing , Laying And Jointing Glazed Stoneware Pipes Class Sp-1 With Stiff Mixture Of Cement Mortar In The Proportion Of 1:1 Including Testing Of Joints Etc. 150 Mm Diameter , Providing And Fixing Square-Mouth S.W Gully Trap Class Sp-1 Complete With C.I Grating Brick Masonry Chamber With Wter Tight C.I Cover With Frame Of 300X300mm Size The Weight Of Cover To Be Not Less Than 4.50Kg And Frame To Be Not Less Than 2.70Kg. As Per Standard Design. , Providing And Laying Cement Concrete 1:5:10 All Round S.W Pips Including Bed Concrete As Per Standard Design. 15Mm Dia S.W Pipe. , Constructing Brick Masonry Chamber For Underground C.I Inspection Chamber And Bends With Bricks In Cement Mortar 1:4. 455X610 Mm Iternal Dimensions Total Weight Of Cover With Frame To Be Not Less Than 38Kg Reinforced Cement Concrete Top Slab With 1:1.5:3 Mix , Providing And Fixing G.I Pipes Complete With G.I Fittings And Clsmps Including Cutting And Making Good The Walss Etc. Internal Work Exposed On Wall. , 15Mm Dia Nominal Bore , 25Mm Dia. Nominal Bore , 50Mm Dia. Nominal Bore , Providing And Fixing Ball Valve Of Approved Quality Complete High Or Low Pressure With Plastic Floats 25Mm Dia. Nominal Bore , Providing And Fixing Gun Metal Non-Return Valve Of Approved Quality :25Mm Nominal Bore. , Providing And Fixing Gun Metal Non-Return Valve Of Approved Quality :50Mm Nominal Bore. , Providing And Fixing Uplasticised Pvc Connection Pipe With Brass Unions 15Mm Nominal Bore. , Providing And Placing On Terrace Polyethylene Water Storage Tank Isi:12701 Marked With Cover And Suitble Locking Arrangement And Amking Necessary Holkes For Intel Outlet And Overflow Pipes But Without Fittings And The Base Vsupport For Tank. , Providing And Fixing Soil,Waste And Vent Pipes:Sand Cast Iron S&S Pipe As Per Is:1729 100Mm , Providing And Fixing Soil,Waste And Vent Pipes:Sand Cast Iron S&S Pipe As Per Is:1729 75Mm , Providing And Fixing Plain Bend Of Required Degree.100Mm Sand Cast Iron S &S As Per Is:1729 , Providing And Fixing Single Equalplain Invert Branch Of Required Degree.100X100x100mm Sand Cast Iron S &S As Per Is:1729 , Providing And Fixing Single Equalplain Invert Branch Of Required Degree.75X75x75mm Sand Cast Iron S &S As Per Is:1729 , Providing And Fixing Mirror Of Superior Glass And Of Required Shape And Size With Plastic Moulded Frame Of Approved Make And Shade With 6Mm Thick Hard Board Backing :Rectangular Shape 453X357mm. , Providing And Fixing Terminal Guard: Sand Cast Iron S&S Pipe As Peris-1729 , Providing And Fixing M.S Stays And Clamps For Sand Iron/Centrifugally Cast Iron Pipes Of Diameter:10Mm Dia. , Providing And Fixing C.P Brass Long Body Bib Cock Of Approved Quality Conforming To Is Standards And Weighing Not Less Than 690 Gms.15Mm Nominal Bore. , Providing And Fixing C.P Brass Stop Cock Of Standard Design And Of Approved Make Conforming To Is:8931. 15Mm Nominal Bore. , Providing And Fixing C.P Brass Angle Valve For Basin Mixer And Geyser Points Of Approved Quality Conforming To Is:8931. 15Mm Nominal Bore. , Providing And Fixing 450 Mm Long Towel Rail With Total Length Of 495 Mm, 78 Mm Wide And Effective Height Of 88 Mm, Weighing Not Less Than 170 Gms , Providing And Fixing C.P. Brass Angle Valve For Basin Mixer And Geyser Points Of Approved Quality Conforming To Is:8931 15 Mm Nominal Bore , Providing And Fixing C.P. Brass Long Body Bib Cock Of Approved Quality Conforming To Is Standards And Weighing Not Less Than 690 Gms. 15 Mm Nominal Bore , Providing And Fixing On Wall Face Unplasticised Rigid Pvc Rain Water Pipes Conforming To Is : 13592 Type A, Including Jointing With Seal Ring Conforming To Is : 5382, Leaving 10 Mm Gap For Thermal Expansion, (I) Single Socketed Pipes. 75 Mm Diameter , Providing And Fixing Ptmt Soap Dish Holder Having Length Of 138Mm, Breadth 102Mm Height Of 75Mm With Concealed Fitting Arrangments Weighing Not Less Than 106 Gms. , Sanitary Works , Providing And Fixing One Piece Construction White Vitreous China Squatting Plate With An Integral Longitudinal Flushing Pipe, White P.V.C. Automatic Flushing Cistern, With Fittings, Standard Size G.I. / Pvc Flush Pipe For Back And Front Flush With Standard Spreader Pipes With Fittings, G.I Clamps And C.P. Brass Coupling Complete, Including Painting Of Fittings And Cutting And Making Good The Walls And Floors Etc. Wherever Required :Range Of Two Squatting Plates With 5 Litre P.V.C. Automatic Flushing Cistern , Providing And Fixing White Vitrepous China Flat Back Or Wall Corner Type Lipped From Urinal Basin Of 430X260xx350mm And 340X410x265mm Size Respectively With Automatic Flushing Cistern With Standard Flush Pipe Abd C.P Brass Spreaders With Brass Unions And G.I Clamps Complete,Including Painting Of Fitting And Brackets Cutting And Making Good The Walls And Floors Wherver Required :One Urinal Basin With 5 Ltr. White P.V.C Automatic Flushing Cistern , Providing And Fixing Soil ,Waste And Vent Pipes Sand Cast Iron S&S Pipe As Per Is:1729 , 100Mm Dia. , 75Mm Dia. , Providing And Fixing Trap Of Self Cleaning Design With Screwed Down Or Hinged Grating With Or Without Vent Arm Complete,Including Cost Of Cutting And Making Good The Walls And Floors: Sand Cast Iron S&S As Per Is-17 , Providing And Fixing Wash Basin With C.I Brackets, 15Mm C.P Brass Pillar Taps,32Mm C.P Brass Waste Of Standard Pattern,Including Painting Of Fitting And Brackets,Cutting And Making Good White Viterous China Wash Basin Size 630X450mm With Single 15Mm C.P Brass Pillar Tap , Providing And Fixing C.P. Brass Shower Rose With 15 Or 20 Mminlet: 100Mm Diameter. , Electrical Work , Wiring For Light Point/Fan Point ,Exhaust Fan Point With 1.5Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface Steel Conduit With Modular Switch,Modular Plate Suitable G.I Box For Earhting The Point With 1.5 Sqmm Frls Pvc Insulated Copper Conductor Single Core Cable Isi Marked 1100 Volts Grade As Required For Group C Point Including Ceiling Rose And Lamps Holder As Required , Supplying And Fixing 5/6 Amps.Modular Type Switch On The Existing Modular Plate & Switch Box Including Cconnections But Excluding Modular Plate,Ac Etc. As Required. , Supply/Fixing 1 Or 2 Module Gi Box Of Size 75X75 Mm Along With Modular Base And Cover Plate For Modular Switches In Recess Etc As Required. , Supply/Fixing 3 Module Gi Box Of Size 100X75 Mm Along With Modular Base And Cover Plate For Modular Switches In Recess Etc As Required. , Supply/Fixing 6 Module Gi Box Of Size 200X75 Mm Along With Modular Base And Cover Plate For Modular Switches In Recess Etc As Required. , Supply/Fixing 8 Module Gi Box Of Size 125X125 Mm Along With Modular Base And Cover Plate For Modular Switches In Recess Etc As Required. , Supply/Fixing 12 Module Gi Box Of Size 200X150 Mm Along With Modular Base And Cover Plate For Modular Switches In Recess Etc As Required. , Supplying And Fixing Following Piano Type 3Pin 5/6A Socket Outlet. , Supplying And Fixing 3 Pin 5 Amps Ceiling Rose On The Existing Junction Box/Wooden Block Including Connections Etc As Required. , Supplying And Fixing Suitable Size G.I Box With Modular Plate And Cover In Front On Surface Including providing and Fixing 3 Pin 5\6 Amps Modular Socket Outlet And 5/6 Amps Modular Switch Connections Etc. As Required. , Supplying And Fixing Two Module Stepped Type Electronic Fan Regulator On The Existing Modular Plate Switch Box Including Connections But Excluding Modular Plate Etc. As Required. , Supplying And Fixing Modular Blanking Plate On The Existing Modular Plate And Switch Box Excluding Modular Plate As Required. , Supplying And Fixing Suitable Size G.I Box With Modular Plate And Cover In Front On Surface Including providing and Fixing 6 Pin 15/16 Amps And 5/6 Amps Modular Socket Outlet And 15/16 Amps Modular Switch Connections Etc As Required. , Supplying And Fixing 6 Way Double Door Surface Mounting Vertical Type 240 Volts Tpn Mcb Distribution Board Of Sheet Steel Dust Protected Duly Powder Painted,Including Of 63 Amps Tinned Copper Bus Bars,Common Neutral Link,Earth Bar,Din Bar For Mounting Mcbs Of Havells Make Model Load Line Or Its Equivalent Of Legrand/Abb/L&T/Scienmense Make Inclduing Painting Earhting Etc. As Required. , Supplying And Fixing Single Pole 5Amps-32 Amps Rating 240/415 Volts C Series Miniature Circuit Breaker Suitable For Including Loand Of Following Pole In The Existing Mcb Db Complete With Connections,Testing And Commisioning Etc As Required. , Supplying And Fixing Of 200Mm Sweep Double Ball Bearing Type Exhaust Fan Of Make Usha/Crompton/Phllips/Or Its Equivalent In All Respect As Required And Directed By Enginner-In-Charge. , Led Down Lighter (Smd Type) (System Lumen Efficacy ≥ 105 120 Lm/Watt ) Supplying, Installation, Testing & Commissioning Of Led Recessed/ Surface Down Light. , 30 Watt , 12 -15 Watt , Led Batten Light (System Lumen Efficacy ≥105 120 Lm/Watt) Supplying, Installation, Testing & Commissioning Of Led Surface Mounted Batten Light Of Following Body Material And Construction As Per Is : 10322 , 18- 22 Watt , Providing And Fixing 32 Amps Single Pole Mcb In Existing Cubical Panel Board Including Drilling Holes In Cubical Panel Making Connection Etc. Includingtesting And Commissioning Etc As Required. , Wiring For Circuit/Sub-Main Wiring Along With Earthwire The Following Size Of Frls Pvc Insulated Copper Conductor Single Core Cable I.S.I Marked 1100 Volts Grade In Surface/Recessed Steel Conduitas Required. , 2 X1.5 Sqmm+1X1.5 Sqmm Earth Wire , 2 X2.5 Sqmm+1X2.5 Sqmm Earth Wire , 2 X 4 Sqmm+1X4 Sqmm Earth Wire , 2 X 6 Sqmm+1X6sqmm Earth Wire , Supply , Installation,Testing And Commissiong Of 1200 Mm Sweep, Bee 5 Star Rated,Ceiling Fan. , Water Cooler , Ceiling Fan , Wall Hanging Fan , Interior Work , Furniture Work , Mid Back Mesh Revolving Chair Black , High Back Revolving Chair Black/Blue , Workstation 8 Seater (8 Seater Table) Size: 96X36X30 , Bookcase Steel (4 Shelf Glass) Size: 72X30X18 , Workstation 8 Seater (8 Seater Table) Size: 12X2x2 , Directior Table Size: 72X36X30 , 5 Seater Sofa With Table , Air Conditioner , 2 Ton 5 Star Voltas , 1 Ton 5 Star , A/C Installing Charge , Wall Stand , Computer , Hp A/O Desktop 27-Cr0902in I3-13T 8Gb/512Gb/Win/Mso , Hp A/O Desktop 24-Cr0902in I3-13T 8Gb/512Gb/Win/Ms , Hp Printer Smart Tank 580Aio P/S/C/W , Cctv Camera , Dvr Cp Plus 8Ch , Smps 10A , Bullet Camera 2.4Mp (Guard+Mic) , Dome Camera 2.4Mp (Guard+Mic) , Hdd 2Tb , Pvc Box , Bnc Connector Set , Rack 2U , Installation Charge , 3+1 Cable , 1.5 Mtr. Hdmi Cable , 32 Inch Led Smart Tv
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 8
Uttarakhand View Result →
32.
Public Administrative Department #11276744 Technical Bid
Tender for Labour Engaged For Desilting,Readjustment Of Manholes Covers, Diverting The Direction Of Water Dewatering During The Execution Of Work And Disposal Away From Site. , Dismantling Tile Work In Floors And Roofs Laid In Cement Mortar Including Stacking Material Within 50 Meters Lead For Thickness Of Tiles Above 25 Mm And Upto 40 Mm. , Dismantling Dressed Stone Work Ashlar Face Stone Work, Marble Work Or Precast Concrete Work Manually/By Mechanical Means Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Meters Lead As Per Direction Of Engineer-In-Charge , Dismantling Roofing Including Ridges, Hips Valleys And Gutters Etc., And Stacking The Material Within 50 Meters Lead. , Dismantling Of Flexible Pavement (Bituminous Courses) By Mechanical Means And Disposal Of Dismantled Material Upto A Lead Of 1 Kilometer, As Per Direction Of Engineer-In-Charge. , Dismantling Manually/ Mechanically Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Meters Lead As Per Direction Of Engineer-In-Charge: Bituminous Road. , Demolishing Cement Concrete Manually/By Mechanical Means Including Disposal Of Material Within 50 Meters Lead As Per Direction Of Engineer-Incharge:1:4:8 Or Leaner Mix (I/C Equivalent Design Mix) , Demolishing Lime Concrete Manually/By Mechanical Means And Disposal Of Material Within 50 Meters Lead As Per Direction Of Engineer-In-Charge. , Demolishing Brick Work Manually/By Mechanical Means Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Meters Lead As Per Direction Of Engineer-In-Charge:In Cement Mortar , Demolishing Cement Concrete Manually/By Mechanical Means Including Disposal Of Material Within 50 Meters Lead As Per Direction Of Engineer-Incharge: 15.2.1 1:3:6 Or Richer Mix (I/C Equivalent Design Mix) , Demolishing Reinforced Cement Concrete Work Manually/By Mechanical Means Including Stacking Of Steel Bars And Disposal Of Unserviceable Material Within 50 Meters Lead As Per Direction Of Engineer-In-Charge. , Demolishing R.B Work Manually/By Mechanical Means Including Stacking Of Steel Bars And Disposal Of Unserviceable Material Within 50 Meters Lead As Per Direction Of Engineer-In-Charge. , Earth Work In Excavation By Manual Means In Trenches For Foundations, Drains, Pipes, Cables Etc. (Not Exceeding 1.5 M In Width) And For Shafts, Wells, Cesspits And The Like Not Exceeding 10 Sqm On Plan, Including Dressing Of Sides And Ramming Of Bottoms Lift Upto 1.5 M, Including Getting Out Excavated Earth And Disposal Of Surplus Excavated Earth As Directed: All Kinds Of Soil : , Earth Work In Bulk Excavation By Mechanical Means (Hydraulic Excavator) Over Areas (Exceeding 30 Cm In Depth, 1.5 M In Width As Well As 10 M2 On Plan) Including Disposal Of Excavated Earth Lead Upto 50 Meters And Lift Upto 1.5 M, As Directed By Engineer-In-Charge. All Kinds Of Soil : , Earth Work In Surface Excavation Not Exceeding 30 Cm In Depth But Exceeding 1.5 M In Width As Well As10 Sqm On Plan Including Disposal Of Excavated Earth, Leadupto50meterand Lift Upto 1.5M, As Directed By Engineer-In-Charge.All Kinds Of Soil : , Earth Work In Excavation By Mechanical Means (Hydraulic Excavator) In Trenches For Foundations, Drains, Pipes, Cables Etc. (Not Exceeding 1.5 M In Width) And For Shafts, Wells, Cesspits And The Like Not Exceeding 10 Sqm On Plan, Including Dressing Of Sides And Ramming Of Bottoms Lift Upto 1.5 M, Including Getting Out Excavated Earth And Disposal Of Surplus Excavated Earth As Directed, Within A Lead Of 50 Metres:All Kinds Of Soil : , Removal Of Excavated Mulba Dismantled Or Unserviceable Material From The Site Of Work By Mechanical Transport Or Animal Transport Or Otherwise Including Loading/Unloading(Complete Job) , Providing And Laying In Position Cement Concrete Of Specified Grade Including Curing But Excluding The Cost Of Centring And Shuttering. All Work Upto Plinth Level With:1:4:8 (1 Cement : 4 Coarse Sand : 8 Graded Stone Aggregate 40 Mm Nominal Size) , Providing And Laying In Position Cement Concrete Of Specified Grade Including Curing But Excluding The Cost Of Centring And Shuttering. All Work Upto Plinth Level With: 4.4.8 1:5:10 (1 Cement : 5 Coarse Sand : 10 Graded Stone Aggregate 40 Mm Nominal Size) , Providing And Laying In Position Cement Concrete Of Specified Grade Including Curing But Excluding The Cost Of Centring And Shuttering. All Work Upto Plinth Level With:1:2:4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size) , Providing And Laying In Position Cement Concrete Of Specified Grade Including Curing But Excluding The Cost Of Centring And Shuttering. All Work Upto Plinth Level With:1:3:6 (1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20 Mm Nominal Size) , Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete Including Curing But Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement. All Works Upto Plinth Level 1:1½:3 (1 Cement : 1½ Coarse Sand : 3 Graded Stone Aggregate 20 Mm Nominal Size) , Providing And Laying Cement Concrete In Retaining Walls, Return Walls, Walls (Any Thickness) Including Attached Pilasters, Columns, Piers, Abutments, Pillars, Posts,Struts, Buttresses, String Or Lacing Courses, Parapets, Coping, Bed Blocks, Anchors Blocks, Plain Window Sills, Fillets Etcupto Floor V Level, Including Curing But Excluding The Cost Of Centring, Shuttering And Finishing With.1:3:6 (1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20 Mm Nominal Size) , Reinforced Cement Concrete Work In Walls (Any Thickness) Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Upto Floor Five Level Including Curing But Excluding Cost Of Centering Shuttering, Finishing And Reinforcement. 1½:3 (1 Cement : 1½ Coarse Sand : 3 Graded Stone Aggregate 20 Mm Nominal Size) , Providing And Laying In Position Ready Mixed M-25 Grade Concrete For Reinforced Cement Concrete Work, Using Cement Content As Per Approved Design Mix, Manufactured In Fully Automatic Batching Plant And Transported To Site Of Work In Transit Mixer For All Leads, Having Continuous Agitated Mixer, Manufactured As Per Mix Design Of Specified Grade For Reinforced Cement Concrete Work Including Pumping Of R.M.C. From Transit Mixer To Site Of Laying , Excluding The Cost Of Centering, Shuttering Finishing And Reinforcement Including Cost Of Admixtures In Recommended Proportions As Per Is : 9103 To Accelerate/ Retard Setting Of Concrete, Improve Workability Without Impairing Strength And Durability As Per Direction Of The Engineer- In - Charge. Note: - Cement Content Considered In This Item Is @ 330 Kg/ Cum. Excess/ Less Cement Used As Per Design Mix Is Payable/ Recoverable Separately.All Works Upto Plinth Level , Providing And Laying In Position Ready Mixed M-25 Grade Concrete For Reinforced Cement Concrete Work, Using Cement Content As Per Approved Design Mix, Manufactured In Fully Automatic Batching Plant And Transported To Site Of Work In Transit Mixer For All Leads, Having Continuous Agitated Mixer, Manufactured As Per Mix Design Of Specified Grade For Reinforced Cement Concrete Work Including Pumping Of R.M.C. From Transit Mixer To Site Of Laying , Excluding The Cost Of Centering, Shuttering Finishing And Reinforcement Including Cost Of Admixtures In Recommended Proportions As Per Is : 9103 To Accelerate/ Retard Setting Of Concrete, Improve Workability Without Impairing Strength And Durability As Per Direction Of The Engineer- In - Charge. Note: - Cement Content Considered In This Item Is @ 330 Kg/ Cum. Excess/ Less Cement Used As Per Design Mix Is Payable/ Recoverable Separately. All Works Above Plinth Level Upto Floor V Level , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form Work For: Foundations, Footings, Bases For Columns , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form Work For Retaining Walls, Return Walls, Walls (Any Thickness) Including Attached Pilasters Buttresses, Plinth And String Course Fillets, Kerbs Andsteps Etc. , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For: Lintel, Beams, Plinth Beams, Girders, Bressumers And Cantilevers , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For:Columns, Pillars, Piers, Abutments, Posts And Struts. , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For:Edges Of Slabs And Breaks In Floors And Walls , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For: Suspended Floors, Roofs, Landings, Balconies And Access Platforms. , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For: Arches, Domes, Vaults Upto 6 M Span , Steel Reinforcement For Reinforced Cement Concrete Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Above Plinth Level With Cold Twisted Bar , Steel Work Welded In Built Up Sections/Framed Work, Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer Using Structural Steel Etc. As Required.In Gratings, Frames, Guard Bar, Ladder, Railings, Brackets, Gates And Similar Works. , Structural Steel Work In Built Up Sections, Trusses And Framed Work, Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer All Complete. Welded , Providing And Laying River Bed Material On The Road Surface By Way Of Spreading The Same In Uniform Layer Not Exceeding 20Cm In Depth, Watering And Compacting With Vibratory Power Road Roller Of 8-10 Tonne Capacity Incl Carriage Of Material From Source To Site Of Work (All Leads , Lifts Complete).The Measurement Is To Be Taken Of Compacted / Finished Work. , Filling Available Excavated Earth (Excluding Rock) In Trenches, Plinth, Sides Of Foundations Etc. In Layers Not Exceeding 20 Cm In Depth, Consolidating Each Deposited Layer By Ramming And Watering, Lead Upto 50 M And Lift Upto 1.5 M. , Surface Dressing Of The Ground Including Removing Vegetation And In-Equalities Not Exceeding 15 Cm Deep And Disposal Of Rubbish, Lead Upto 50 M And Lift Upto 1.5 M In -All Kinds Of Soil. , Providing And Fixing 60Mm Interlocked Paver Tile Over A Layer Of Cement Mortar 1:4 Mix Incl Filling Of Joints With Cement Mortar 1:3 (Complete Job) , Providing And Laying Factory Made Chamfered Edge Cement Concrete Paver Blocks In Footpath, Parks, Lawns, Drive Ways Or Light Traffic Parking Etc, Of Required Strength, Thickness & Size/ Shape, Made By Table Vibratory Method Using Pu Mould, Laid In Required Colour & Pattern Over 50Mm Thick Compacted Bed Of Sand, Compacting And Proper Embedding/Laying Of Inter Locking Paver Blocks Into The Sand Bedding Layer Through Vibratory Compaction By Using Plate Vibrator, Filling The Joints With Sand And Cutting Of Paver Blocks As Per Required Size And Pattern, Finishing And Sweeping Extra Sand Complete All As Per Direction Of Engineer-In-Charge. 80 Mm Thick cement concrete Paver Block Of M-30 Grade With Approved Color Design And Pattern. , 12Mm Cement Plaster Of Mix: 1 : 6 ( 1 Cement : 6 Fine Sand) , 12Mm Cement Plaster Of Mix: 1 : 4 ( 1 Cement : 4 Fine Sand) , Brick Work With Common Burnt Clay (Non-Modular) Bricks Of Class Designation 7.5 In Foundation And Plinth Including Curing In : Cement Mortar 1:6 ( 1 Cement : 6 Coarse Sand) , Extra For Brick Work With Common Burnt Clay Bricks/Cement Concrete Bricks In Superstructure Above Plinth Level Upto Floor Five Level , Tile Brick Masonry With Common Burnt Clay Tile Bricks Of Class Designation 10 In Foundation And Plinth Including Curing Complete In: Lime Mortar 1:1:1 (1 Lime Putty : 1 Surkhi : 1 Fine Sand) , Providing And Laying Bituminous Macadam Using Crushed Stone Aggregates Of Specified Grading Premixed With Bituminous Binder, Transported To Site By Tippers, Laid Over A Previously Prepared Surface With Paver Finisher Equipped With Electronic Sensor To The Required Grade, Level And Alignment And Rolling With Smooth Wheeled, Vibratory And Tandem Rollers As Per Specifications To Achieve The Desired Compaction And Density, Complete As Per Specifications And Directions Of Engineer-In-Charge. 50 To 100 Mm Average Compacted Thickness With Bitumen Ofgrade Vg-30 @ 3.5% (Percentage By Weight Of Total Mix) Prepared In Drum Type Hot Mix Plant Of 60-90 Tph Capacity , Supplying,Stacking, Laying, Spreading And Compacting Graded Stone Aggregate To Wet Bound Macadam (Wbm-Iii) With Graded Crushed Stone Aggregate Of Size 53Mm To 22.4 Mm In Uniform Thickness,Hand Picking , Rolling With Vibratory Roller 8-10 Tonne Capacity In Stages To Proper Grade And Camber,Applying And Brooming Requisite Type Screening / Binding Material To Fill Up Interstices Of Coarse Aggregate,Watering And Compacting To The Required Density.Complete Job , Providing And Applying Tack Coat Using Hot Straight Run Bitumen Of Grade - Vg-30, Including Heating The Bitumen, Spraying The Bitumen With Mechanically Operated Spray Unit Fitted On Bitumen Boiler, Cleaning And Preparing The Existing Road Surface As Per Specifications. On Bitumen Surface @ 0.50 Kg/Sqm. , Hand-Packing Stones In Wire-Crates; Excluding Cost Of Crates And Stones , Providing And Applying Tack Coat Using Hot Straight Run Bitumen Of Grade - Vg-30, Including Heating The Bitumen, Spraying The Bitumen With Mechanically Operated Spray Unit Fitted On Bitumen Boiler, Cleaning And Preparing The Existing Road Surface As Per Specifications.16.38.1 On W.B.M. @ 0.75 Kg/Sqm. , Providing And Laying Seal Coat Of Premixed Fine Aggregate (Passing 2.36 Mm And Retained On 180 Micron Sieve) With Bitumen Using 128 Kg Of Bitumen Of Grade Vg-30 Bitumen Per Cum Of Fine Aggregate And 0.60 Cum Of Fine Aggregate Per 100 Sqm Of Road Surface Including Rolling And Finishing With Road All Complete , 2.5 Cm Premix Carpet Surfacing With 2.25Cum And 1.12 Cum Of Stone Chippings Of 13.2 Mm And 11.2Mm Size Respectively Per 100 Sqm And 52 Kg And 56 Kg Of Hot Bitumen Per Cum Of Stone Chippings Of 13.2 Mm And 11.2 Mm Size Respectively Including A Tack Coat With Hot Straight Run Bitumen Including Consolidation With Road Roller Of 6 To 9 Tonne Capacity Etc. Complete (Tack Coat To Be Paid For Separately). Vwith Paving Asphalt Grade Vg-30 With No Solvent , 10Cm Thick (Average) Mud Phaska Of Damped Brick Earth On Roofs Laid To Slope Consolidated And Plastered With 25 Mm Thick Mud Mortar Mixed With Bhusa At 35Kg Per Cum Of Earth And Gobri Leaping With Mix 1:1 (1 Clay: 1 Cow Dung) And Covered With Specified Tile Bricks Grouted With Cement Mortar 1:3 (1 Cement: 3 Fine Sand) Mixed With 2% Of Integral Water Proofing Compound By Weight Of Cement And Finishing Neat. 12.25.1 With Common Burnt Clay (Non Modular) Brick Tiles Of Class Designation 10.0 , Providing And Fixing Precoated Galvanized Iron Profile Sheets (Size, Shape And Pitch Of Corrugation As Approved By Engineer-In-Charge) 0.50 Mm (+ 0.05 %) Total Coated Thickness With Zinc Coating 120 Grams Per Sqm As Per Is: 277, In 240 Mpa Steel Grade, 5-7 Microns Epoxy Primer On Both Side Of The Sheet And Polyester Top Coat 15-18 Microns. Sheet Should Have Protective Guard Film Of 25 Microns Minimum To Avoid Scratches During Transportation And Should Be Supplied In Single Length Upto 12 Metre Or As Desired By Engineer-In-Charge. The Sheet Shall Be Fixed Using Self Drilling /Self Tapping Screws Of Size (5.5X 55 Mm) With Epdm Seal, Complete Upto Any Pitch In Horizontal/ Vertical Or Curved Surfaces, Excluding The Cost Of Purlins, Rafters And Trusses And Including Cutting To Size And Shape Wherever Required. , Providing And Fixing Precoated Galvanised Steel Sheet Roofing Accessories0.50 Mm (+0.05 %) Total Coated Thickness, Zinc Coating 120 Grams Per Sqm As Per Is: 277, In 240 Mpa Steel Grade, 5-7 Microns Epoxy Primer On Both Side Of The Sheet And Polyester Top Coat 15-18 Microns Using Self Drilling/ Self Tapping Screws Complete : 12.24.1 Ridges Plain (500 - 600Mm) 12.24.2 Flashings/ Aprons.(Upto 600 , Providing And Fixing 1Mm Thick M.S. Sheet Door With Frame Of 40X40x6mm Angle Iron And 3Mm M.S. Gusset Plates At The Junctions And Corners, All Necessary Fittings Complete, Including Applying A Priming Coat Of Approved Steel Primer. Using Flats 30X6mm For Diagonal Braces And Central Cross Piece. , Providing And Applying White Cement Based Putty Of Specified Thickness, Of Approved Brand And Manufacturer, Over The Plastered Wall Surface To Prepare The Surface Even And Smooth Complete. 2 Mm Thick , Wall Painting With Acrylic Emulsion Paint Of Approved Brand And Manufacture To Give An Even Shade. Two Or More Coats On New Work , Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture To Give An Even Shade. Two Or More Coats On New Work , Finishing Walls With Acrylic Smooth Exterior Paint Of Required Shade On New Work (Two Or More Coats Applied @ 1.67 Liter/10Sqm Over And Including Priming Coat Of Exterior Primer Applied @ 2.20Kg/10Sqm) , Providing And Laying Vitrified Floor Tiles In Different Sizes (Thickness To Be Specified By The Manufacturer) With Water Absorption Less Than 0.08% And Conforming To Is:15622 Of Approved Make, In All Colours And Shades, Laid On 20Mm Thick Cement Mortar 1:4 (1Cement :4 Coarse Sand) Including Grouting The Joints With White Cement And Matching Pigments Etc. Complete Size Of Tile 600X600 Mm , Chequerred Precast Cement Concrete Tiles 22Mm Thick In Footpath And Courtyard, Jointed With Neat Cement Slurry Mixed With Pigment To Match The Shade Of The Tiles, Including Rubbing, Cleaning And Curing Complete, On 20 Mm Thick Bed Of Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand) . Dark Shade Using Ordinary Cement. , Providing And Fixing 15 Mm Nominal Bore C.P. Brass Bib Cock Of Approved Quality Conforming To Is : 8931 , Providing And Fixing 15 Mm Nominal Bore C.P. Brass Long Nose Bib Cock Of Approved Quality Conforming To Is Standards And Weighing Not Less Than 810 Gms. , Pvc Bend , Providing And Fixing Of Pvc Pipe With All Fitting Complete Job , Providing And Fixing Of Pvc Pipe With All Fitting Complete Job , Providing And Fixing On Wall Face Un-Plasticized Rigid Pvc Rain Water Pipes Conforming To Is: 13592 Type A Including Jointing With Seal Ring Conforming To Is: 5382 Leaving 10 Mm Gap For Thermal Expansion. (I) Single Socketed Pipes 75 Mm Diametre , Providing And Fixing Of Pvc Including All Fitting With Complete Job , Providing And Fixing Of Towal Ring With All Fitting With Complete Job , Providing And Inserting Upvc Pipe ( Working Pressure4kg/ Cm2) Single Sockted Pipe 110 Mm Dia , Providing And Fixing G.I. Pipes Complete With G.I. Fittings And Clamps, Including Cutting And Making Good The Walls Etc.: Internal Work-Exposed On Wall 15 Mm Dia. Nominal Bore , Dumping Of Stone Including Cost Of Stone Filling, Including Supply Of Stone And Carriage Complete Job , Providing And Placing On Terrace (At All Floor Levels) Polyethylene Water Storage Tank Isi : 12701 Marked, With Cover And Suitable Locking Arrangement And Making Necessary Holes For Inlet, Outlet And Overflow Pipes But Without Fittings And The Base Support For Tank , Supply Of Wire Crates Of Approved Mesh Including Weaving Binding Sides And Partitionsand Binding Top After Filling Complete Job. , Extra For Every Additional Lift Of 1.5 M Or Part There Of Beyond 1.5 M Height For Hand-Packing Of Stones In Wire-Crates , Providing And Fixing Of Weep Hole With Pvc Pipe Of 100 Mm Dia Complete Job , Providing And Fixing Of Weep Hole With Pvc Pipe Of 110 Mm Dia Complete Job , Stone Work In Super Structure Upto Floor Five Level In Cement Mortar 1:6 ( 1 Cement :6 Coarse Sand) Including Pointing With Cement Mortar 1:2 ( 1 White Cement: 2 Stone Dust) With An Admixture Of Pigment Matching The Stone Shade And Curing Complete: White Sand Stone , Stone Work Plain Ashlar In Super Structure Upto Floor Five Level In Cement Mortar 1:3 ( 1 Cement :3 Coarse Sand) Including Centering, Shuttering And Pointing With Cement Mortar 1:2 ( 1 White Cement: 2 Stone Dust) With An Admixture Of Pigment Matching The Stone Shade And Curing Complete: Red Sand Stone B White Sand Stone , Plastering With Lime Surkhi Mortar Of 20Mm Thickness Including Preparation Of Mortar, Tamping, Curing, Prepared By Traditional Methods Including Mixing Of Gur, Tamarind Water, Dal Etc. As Per Tradition, The Work Is To Be Done With All Leads And Lifts, Surfaces To Be Plastered Shall Be Thoroughly Cleaned Of All Dust, Grease, Oil Etc. All Surfaces Should Be Kept Damp During The Progress Of Work. The Engineer-In-Charge Will Inspect And Approve All Preparatory Work. Curing To Be Done For 21 Days By Means Of Spraying , Roviding And Applying Lime Kara 1:2 (1 Lime: 2 Zikki Powder) Grinding Mortar With Grinding Mill/Manually On Lime Base, On All Flat Surface In Two Coats. First Coat Applying 3 To 4 M Thick And Curing Properly At Least 7 Days, Second Finishing Coat Done After 7 Days Of Previous Coat As Per Tradtional Practice (Thickness Not More Than 6Mm). , Providing Protective Coating Of Water Repellent Siloxane (Transparent In Color) Through Brush Or Spray Until Complete Impregnation Over Completely Cleaned And Dried Stone Or Plastered Surface To Reduce The Absorption Of Water , Taking Out Existing cement concrete Interlocking Paver Blocks From Footpath/ Central Verge, Including Removal Of Rubbish Etc., Disposal Of Unserviceable Material To The Dumping Ground, For Which Payment Shall Be Made Separately And Stacking Of Serviceable Material Within 50 Meter Lead As Per Direction Of Engineer-In-Charge. , Providing And Fixing Steel (White Powder Coated) Crescent Lock For Upvc Sliding Window/ Door With Necessary Screws Etc. Complete , Providing And Fixing Of Steel Banches , Providing And Fixing Glass Panes With Putty And Glazing Clips In Steel Door/ Windows/ Clerestory Window All Complete With 5.00Mm Thick Glass Panes Complete Job , Providing And Fixing Of Soap Dish , Providing And Fixing Inaugration Plate Including Writing Etc. Complete Job. , Carriage Of Materials By Mechanical Transport Including Loading / Unloading & Stacking Complete Sand For An Avg Distance Of 5 Kms , Carriage Of Materials By Mechanical Transport Including Loading / Unloading & Stacking Complete Stone Aggrigate For An Average Distance Of 7 Kms By Mt. , Carriage Of Materials By Mechanical Transport Including Loading / Unloading & Stacking Complete Brick For An Avg Distance Of 5 Kms , Electrification Items : Supply, Installation, Testing & Commissioning Of 5 Mtr Height Decorative Pole Made Of Galavnised Mild Steel Pipe Duly Polyurethane (Pu) Paint Coated With 1 Mtr. Long Double Arm Designer Bracket Is Made Of Round Tube Conforming To Is 1161. The Pole(Od Of 114.3Mm And Thickness-3.6Mm) With Bracket Is Given Pre-Treatment And Finished With Pu Paint Giving It A Pleasing Appearance And Antique Finish. Pole Shall Be Available To Hot Dip Galvanize The Tube Before Painting. Foundation Bolt Size Shall Be 20X600x4nos. With Base Plate Size 300X300x12mm. A Door Is Provided With Electrical Accessories (Connector, Bakelite Sheet And 6 annual periodical maintenance Single Pole Mcb, Cable Looping Termional For 4X4/6Sqmm Copper Cable). Aluminium Casting In Golden Ring Form At Bottom, Middle, Top Of The Pole. The Pole Will Be Supplied With Brackets And Luminaire Combinations To Suit The Requirement. Branding Name Shall Be Embossed At The Bottom Near Junction/Mcb Box. Sticker Not Allowed In The Form Of Company Branding. Pole Shall Be Supplied With Outdoor Post Top Luminaire Of 45 Watt Ip67 Mounted In Suspension Type Having An Approximate Size Of 460Mm Outer Diameter And 635Mm Height, Housing - Aluminium With Designer Steel Aesthetic Crown, Optical Grade Opal Injection Moulded/Clear Polycarbonate Diffuser And Graphite Grey Uv Resistant Colour,Constant Current Electronic, Driver Provided With High Voltage ,Open & Short Circuit Protection And Ambient Temperature -10C To +40C. Supply 150V- 240V Power Factor 0.95 ,Thd ≤ 20% Internal Surge Protection Of 4Kv With Following Specification Of Light Engine For 45W : 4500Lumens, Cct 3000K ±500 Cct ,Cri 70 And Lumen Maintenance Of L70 At 50000 Hours Ip 65 Connectors,Accessories Etc Complete With All Repects. Design Of Pole Should Be Such That It Should Maintains Proper Illumination On Both Side.(Analysis Attached) , Led Flood Light, Powder Coated Pressure Die Cast Aluminium (System Lumen Efficacy ≥105 120 Lm/Watt). Supplying, Installation, Testing & Commissioning Of Flood Light, Powder Coated Pressure Die Cast Aluminium Body With Built In Or Separate Driver As Per The Requirement With Driver Efficiency 85%, Input Voltage: Input Voltage: 140-270 Volt Ac, Frequency 50/60 Hz, Operating Temp Range -5 0C To 50 0C, Internal Surge Protection Of 5 Kv L,N,E As Per Iec 61000-4-5, Driver Efficiency 85%,Thd 10% As Per Iec 61000-3-2, P. F.≥0.95, Ip-66,Ik-10, Cri 70, Under Voltage And Over Voltage Protection, Emi-Emc As Per Cispr -15, Lenses For Beam Angle 30 Deg-120Deg As Per The Application And The Project Requirement., Suitable Tilt Able Fitting, Life Time (Led, Driver & Electrical Circuitry) Of Minimum 50000 Burning Hours With 70% Of Initial Lumen Maintained Till Life Ends As Per Lm80 Extrapolation Ies Tm-21-11 Report, Cct 3000°K / 4000°K / 5700°K /6500°K (As Per Ansi Bin) , Sdcm(Standard Deviation Color Matching) 5, Maximum Power Consumption Should Not More Than The Specified Rating And Fixture Shall Be Ofrelevant Bis Standard Complete In All Respect I/C External Connections With 1.5 Sq Mm Frls/Hffr, Pvc Insulated Copper Conductor Single Core Cable And Earthing Etc. As Required With Minimum 5 Year Oem Warranty. System Lumen Efficacy ≥105 120 Lm/Watt Output .Lm79 & Lm80 Test Report And All Testing Required For Led Fixtures As Per Bis Shall Be Submitted.. Shape Size And Cct Shall Be As Approved By Engineer-Incharge As Per Requirement. (Thermal Management: Heat Sink Of Aluminium Housing Such That Led Junction Temperature Shall Not Rise Above 90°C). 250 Watt , Led Linear Profile (Ac) Led Rgb/Rgbww/ Rgbnw/Rgba/Rgbw, Linear Profile / Wall Washer Luminaire For Façade Lighting With Aluminium Extruded/ Die Cast Housing With Inbuilt Driver Of Following Wattage. Wattage Per Meter 25W , Supply, Installation, Testing & Commissioning Of 1.1 Grade, 4Cx10 Sqmm Al. Armoured Xlpe Sheathed Cable Including Termination (Along With Lugs) , Providing And Fixing Of Gi Pipe 50 Mm Dia , Feeder Pillar 1 Phase 2 Wire, 415V, 1Nos Of 100 Amps Incoming Sp Mccbs Fitted With Outgoing 04 No 32 Amps Sp Mcbs For Service Connections, Distribution Service Pillar Suitable For Outdoor Installation , Made Out Of Crca Sheet Painted Through 7-Tank Process With Pu Painted Busbars 2P, Aluminium With Heat Shrinkable Sleeves And Adequate Capacities Complete With All Accessories 4 Way Distribution Service Pillar. Support Galvanised Angle Frame And Legs (40Mm X 40 Mm X 3Mm) For Distribution Feeder Pillar With Leg Height 1M With 0.3M In Soil Approx [email protected] Per Mtr, Earthing Complete By Gi Pipe 40 Mm Or Gi Rod 20Mm 2.5 Mtr Long Through Gi Strip.Cement Grouting For Support Angle Legs, Spares @ 3%, Erection Charges @10%, Overheads @ 5% (1.0% T&P 0.5% Storage And Handling , 3% Contingency And Safety Equipments, 0.5% Insurance) And Turnkey Factor @25% With Astronomical Timer. , Earthing With Copper Earth Plate 600Mm * 600Mm * 3 Mm Thick Including Accessories, And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Of 2.7 Meter Long Etc. With Charcoal/Coke And Salt As Required. , Wiring For Light Point/Fans Point/Exhaust Fan Point/ Call Bell Point With 1.5 Sq.Mm Frls/Hffr Pvc Insıslated Copper Conductor Single Core Cable In Surface/ Recessed Medium Class Pvc Conduit, With Modular Switch, Modular Plate, Suitable Gf Box And Earthing The Point With 1.5 Sq.Mm Frls/Hffr Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. Group-A , Add For Vetting Charges Consultency And Contigencies @ 2.5 %
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 2
Jammu And Kashmir View Result →
33.
Public Administrative Department #11268513 AOC
Tender For Annual Plan-Project No 543-Take A Break In Payyanaadu-General Civil Work- 1 Building Construction 2 2.8.1:Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil 3 OD368033/2025-2026:Specification code: 60.7.1 .DRY RUBBLE MASONRY _ Dry rubble without concrete levelling course masonry with good quality blasted rubble including packing to compactness to lines and levels cost and conveyance of all materials labour charges etc. complete as per direction of Departmental officers at site. Details of cost for 1 cum. 4 OD368034/2025-2026:1.016-Specification code: OD374290/2022-2023 Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand) 5 5.9.5:Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers 6 5.2.2:Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up tot floor five level excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3( 1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size derived from natural sources) 7 50.6.7.2:Laterate masonry with neatly dressed laterate stone of size 40x20x15cm or nearest size in cement mortar 1:6 for super structure above plinth level up to floor two level including all cost of materials, labour charges etc. 8 50.6.1.5:Solid block masonry using pre cast solid blocks ( Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 Part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement : 6 coarse sand) etc complete 9 5.9.3:Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform 10 5.3:Reinforced cement concrete work in beams, suspended floors, roofs, having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (Zone III) derived from natural sources: 3 graded stone aggregate 20 mm nominal size derived from natural sources). 11 5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more 12 4.1.8:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) 13 OD368479/2025-2026:od1478338/2021_2022 :Supplying and fixing 20mm thick ready made PVC door (75*200)with frame 50*42mm including conveyance,cost of fitting,labour for fixing etc Please Enable Macros to View BoQ information
Contract Date: Jun 11, 2026 Contract Value : 9.55 Lakh
Government Departments No of Bidders 2
34.
Housing Urban and Rular Development #11248806 Price Bid
Tender For Degree College To Panchayat Ghar Kambhal Danga (Under Ut Capex Permanent Restoration)- 2Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with:1:5:10 (1 cement: 5 coarse sand: 10 graded stone aggregate 40 mm nominal size)3Providing & laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work upto plinth level 1:3:6 (1 cement: 3 coarse sand: 6 graded stone agg. 20 mm nominal size) crushed. Incl. 20% Plum4Cemem concrete mooing 1.2.4 (icemem. 2 coarse sana. 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry and curing complete, but excluding the cost of nosing of steps etc. complete. 50 mm thick with 20mm nominal size stone5Centering and shuttering including strutting, propping etc. and removal of form for:5.1Foundations, footings, bases of columns etc. for mass concrete5.2Suspended floors, roofs, landings, balconies and access platforms. Proviuing and saying in position Specimen grade or remordeu cemem6concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. All works upto plinth level 1:12:3 (1 cement: 1½ coarse sand: 3 graded stone aggregate 20 mm nominal size)7Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo-Mechanically Treated bars of grade Fe-500D or more.8Carriage of material by M.T incl. loading, unloading etc. complete8.1Sand for avg. lead 50 Km8.2Stone agg. Below 40mm avg lead 15 Km8.3Stone lead 5 km
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
Jammu and Kashmir View Result →
35.
Water Resources and Irrigation #11220406 Price Bid
Tender for Excavation In Dumped Stones Or Malba Including Stacking Of Serviceable And Unserviceable Material Separately And Disposal Of Unserviceable Material, Lead Up To 50 M And Lift Up To 1.5 M, Disposed Material To Be Neatly Dressed. , Earth Work In Excavation By Mechanical Means (Hydraulic Excavator) / Manual Means In Foundation Trenches Or Drains (Not Exceeding 1.5 M In Width Or 10 Sqm On Plan), Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soil As Directed, Within A Lead Of 50 M. All Kinds Of Soil. , Supplying Of Good Earth In Rough Excavation, Banking Excavated Earth In Layers Not Exceeding 20 Cm In Depth, Breaking Clods, Watering, Rolling Each Layer With ½ Tonne Roller, Or Wooden Or Steel Rammers, And Rolling Every 3Rd And Top-Most Layer With Power Roller Of Minimum 8 Tonnes And Dressing Up, In Embankments For Roads, Flood Banks, Marginal Banks, And Guide Banks For Filling Up Ground Depresssion Lead Upto 15 Km And Lift Upto 1.50 M. , Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level : 1:4:8 (1 Cement : 4 Coarse Sand (Zone-Iii) : 8 Graded Stone Aggregate 40 Mm Nominal Size) , Brick Work With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 In Foundation And Plinth In: Cement Mortar 1:6 (1 Cement : 6 Coarse Sand) , 15 Mm Cement Plaster On Rough Side Of Single Or Half Brick Wall Finished With A Floating Coat Of Neat Cement Of Mix :1:4 (1 Cement: 4 Fine Sand) , Providing And Laying Class Sn-8 Dwc Structed Wall Polyethylene Piping System (Pipe With Online/Offline Coupler And Elastomeric Sealing Ring) With Non Smooth External Annular Corrugated And Smooth Internal Surface (Double Wall) For Non Pressure Underground Sewerage And Drainage Application As Conforming To Is 16098 (Part-Ii): 2013, This Includes Jointing Of Pipes & Fittings With Solvent Cement,Thermostat Sealing, & Testing Of Joints Complete As Per Direction Of Engineer-In-Charge. 600 Mm Nominal Inner Dia Pipes , Constructing Brick Masonry Road Gully Chamber 45X45x77.5 Cm With Bricks In Cement Mortar 1:4 (1 Cement : 4 Coarse Sand ) With Precast Reinforced Cement Concrete Vertical Grating Complete As Per Standard Design : With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 , Constructing Brick Masonry Circular Manhole 1.22 M Internal Dia At Bottom And 0.56 M Dia At Top In Cement Mortar 1:4 (1 Cement :4 Coarse Sand) Inside Cement Plaster 12 Mm Thick With Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) Finished With A Floating Coat Of Neat Cement Foundation Concrete 1:3:6 (1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 40 Mm Nominal Size) And Making Necessary Channel In Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size) Finished With A Floating Coat Of Neat Cement, All Complete As Per Standard Design : 1.68 M Deep With Steel Fibre Reinforced Concrete Cover And Frame (Heavy Duty Hd-20 Grade Designation) 560 Mm Internal Diameter Conforming To I.S. 12592, Total Weight Of Cover And Frame To Be Not Less Than 182 Kg. Fixed In Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size) Including Centering, Shuttering All Complete. (Excavation, Foot Rests And 12 Mm Thick Cement Plaster At The External Surface Shall Be Paid For Separately) : With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5. , Providing And Laying Non-Pressure Np4 Class (Heavy Duty) Reinforced Cement Concrete Pipes Including Collars / Spigot Jointed With Stiff Mixture Of Cement Mortar In The Proportion Of 1:2 (1 Cement : 2 Fine Sand) Including Testing Of Joints Etc. Complete : 1000 Mm Dia. Reinforced Cement Concrete Pipes (Laying By Manual/Mechanical Means). , Providing And Laying Non-Pressure Np2 Class (Light Duty) Reinforced Cement Concrete Pipes With Collars Jointed With Stiff Mixture Of Cement Mortar In The Proportion Of 1:2 (1 Cement : 2 Fine Sand) Including Testing Of Joints Etc. Complete :300 Mm Dia. Reinforced Cement Concrete Pipe , Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement - All Work Up To Plinth Level : 1:2:4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size) , Providing And Laying In Position Ready Mixed Plain Cement Concrete, With Cement Content As Per Approved Design Mix And Manufactured In Fully Automatic Batching Plant And Transported To Site Of Work In Transit Mixer For All Leads, Having Continuous Agitated Mixer, Manufactured As Per Mix Design Of Specified Grade For Plain Cement Concrete Work, Including Pumping Of R.M.C. From Transit Mixer To Site Of Laying And Curing, Xcluding The Cost Of Centering, Shuttering And Finishing, Including Cost Of Curing, Admixtures In Recommended Proportions As Per Is : 9103 To Accelerate/Retard Setting Of Concrete, Improve Workability Without Impairing Strength And Durability As Per Direction Of The Engineer-In-Charge. Note : Excess/Less Cement Used Than Specified In This Item Is Payable/ Recoverable Separately M-10 Grade Plain Cement Concrete (Cement Content Considered @ 220 Kg/Cum) , Centering And Shuttering Including Strutting,Propping Etc.And Removal Of Form For:Foundations,Footings,Bases Of Columns,Etc.Formass Concrete , Centering And Shuttering Including Strutting,Propping Etc.And Removal Of Form For: Walls(Anythickness) Including Attached Pilasters,Butteresses, Plinth And String Courses Etc. , Centering And Shuttering Including Strutting,Propping Etc.And Removal Of Form For:Suspended Floors,Roofs,Landings,Balconies And Access Platform. , Providing And Laying In Position Machine Batched And Machine Mixed Design Mix M-25 Grade Cement Concrete For Reinforced Cement Concrete Work, Using Cement Content As Per Approved Design Mix, Including Pumping Of Concrete To Site Of Laying But Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement, Including Admixtures In Recommended Proportions As Per Is: 9103 To Accelerate, Retard Setting Of Concrete, Improve Workability Without Impairing Strength And Durability As Per Direction Of Engineer-In-Charge.(Note :- Cement Content Considered In This Item Is @ 330 Kg/Cum.Excess/ Less Cement Used As Per Design Mix Is Payable/Recoverable Separately).All Works Upto Plinth Level , Steel Reinforcement For R.C.C.Work Including Straightening,Cutting, Bending,Placing In Position And Bind In Gall Complete Upto Plinth Level. Thermo-Mechanically Treated Bars Of Grade Fe-500D Or More. , Cement Concrete Flooring 1:2:4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate)Finished With A Floating Coat Of Neat Cement,Including Cementslurry,But Excluding The Cost Of Nosingofsteps Etc.Complete. 40Mm Thick With 20Mm Nominal Size Stone Aggregate. , Providing And Placing In Position 100 Mm Thick Factory Made Machine Batched & Machine Mixed Precast Reinforced Cement Concrete Rectangular Covers On Drains Of Footpath Of Various Sizes, Of M-25 Grade Cement Concrete For Reinforced Cement Concrete Work, Including Cost Of Centering, Shuttering, Reinforcement Of 8 Mm Dia Tmt Bars Of Fe 500 Grade @ Maximum 100Mm C/C On Both Ways , Neat Cement Punning On Finished Surface, Properly Encased On All Edges With 1.6 Mm Thick , 100 Mm Wide Ms Sheet Duly Painted Over Priming Coat , Reinforcement To Be Welded At Edges With Ms Sheet And Providing 2 Nos. 12 Mm Dia Bar For Hooks Etc I/C Cost Of Cartage, All Leads & Lift, Handling At Site Etc. All Complete As Per Direction Of Engineer-In-Charge. , Providing And Laying Rmc Of M-30 Grade By Using Minimum 400 Kg. Of Cement (43 Grade Opc) Per Cum Of Concrete In Roads/Streets Manufactured In Automatic Rmc Plant Using Coarse Sand And Graded Stone Aggregate Of 20 Mm Nominal Size In Appropriate Proportion As Per Approved Design Criteria Including Transportation To Site In Transit Mixer, Including Cost Of Concrete To Improve Workability Wit Out Impairing Strength And Durability As Per Specification Including Spreading And Compacting Mechanically By Using Needle And Surface Vibrators, Leveling To Required Slops And Camber, Finishing By Contractor/ Expansion, Construction Of Cross/ Longitudinal Joints With Approved Joints Filler And Sealants, Etc. Complete As Per Direction Of Engineer-In-Charge(Cost Of Joint Filler & Sealants Shall Be Paid For Separately Under Relevant Item). Note: Cement Content Considered In M-30 Is @400 Kg/Cum. Rc Using Minimum Cement @400 Kg/Cum. Cement Concrete Manufactured In Automatic Batching Plant (Rc Plant) Including Transportation To Site In Transit Mixer. , Preparation And Consolidation Of Sub Grade With Power Road Roller Of 8 To 12 Tonne Capacity After Excavating Earth To An Average Of 22.5 Cm Depth, Dressing To Camber And Consolidating With Road Roller Including Making Good The Undulations Etc. And Re-Rolling The Sub Grade And Disposal Ofsurplus Earthwith Lead Upto 50 Metres. , Supplying And Stacking At Site. 90 Mm To 45 Mm Size Stone Aggregate , Supplying And Stacking At Site.63 Mm To 45 Mm Size Stone Aggregate , Supplying And Stacking At Site.53 Mm To 22.4 Mm Size Stone Aggregate , Supplying And Stacking At Site.Moorum , Supplying And Stacking At Site. Stone Screening 13.2 Mm Nominal Size (Typea) , Supplying And Stacking At Site.Stone Screening 11.2 Mm Nominal Size (Type B) , Laying, Spreading And Compacting Stone Aggregate Of Specified Sizes To Wbm Specifications In Uniform Thickness, Hand Picking, Rolling With 3 Wheeled Road/Vibratory Roller 8-10 Tonne Capacity In Stages To Proper Grade And Camber, Applying And Brooming Requisite Type Of Screening /Binding Material To Fill Up Interstices Of Coarse Aggregate, Watering And Compacting To The Required Density . , Providing And Applying Tack Coat Using Hot Straight Run Bitumen Of Grade Vg - 10, Including Heating The Bitumen, Spraying The Bitumen With Mechanically Operated Spray Unit Fitted On Bitumen Boiler, Cleaning And Preparing The Existing Road Surface As Per Specifications : On W.B.M. @ 0.75 Kg / Sqm , Providing And Laying Bituminous Macadam Using Crushed Stone Aggregates Of Specified Grading Premixed With Bituminous Binder, Transported To Site By Tippers, Laid Over A Previously Prepared Surface With Paver Finisher Equiped With Electronic Sensor To The Required Grade, Level And Alignment And Rolling With Smooth Wheeled, Vibratory And Tandem Rollers As Per Specifications To Achieve The Desired Compaction And Density, Complete As Per Specificatons And Directions Of Engineer-In-Charge. 50 To 100 Mm Average Compacted Thickness With Bitumen Of Grade Vg-30 @ 3.50% (Percentage By Weight Of Total Mix) Prepared In Batch Type Hot Mix Plant Of 100-120 Tph Capacity. , Providing And Applying Tack Coat Using Hot Straight Run Bitumen Of Grade Vg - 10, Including Heating The Bitumen, Spraying The Bitumen With Mechanically Operated Spray Unit Fitted On Bitumen Boiler, Cleaning And Preparing The Existing Road Surface As Per Specifications :On Bituminous Surface @ 0.50 Kg / Sqm , Providing And Laying Bituminous Concrete Using Crushed Stone Aggregates Of Specified Grading, Premixed With Bituminous Binder And Filler, Transporting The Hot Mix To Work Site By Tippers, Laying With Paver Finisher Equiped With Electronic Sensor To The Required Grade, Level And Alignment And Rolling With Smooth Wheeled, Vibratory And Tandem Rollers To Achieve The Desiredcompaction And Density As Per Specification, Complete And As Per Directions Of Engineer-In-Charge. 40/50 Mm Compacted Thickness With Bitumen Of Grade Vg-30 @ 5.5% (Percentage By Weight Of Total Mix) And Lime Filler @ 3% (Percentage By Weight Of Aggregate) Prepared In Batch Type Hot Mix Plant Of 100-120 Tph Capacity. , Filling Available Excavated Earth (Excluding Rock) In Trenches, Plinth, Sides Of Foundations Etc. In Layers Not Exceeding 20Cm In Depth, Consolidating Each Deposited Layer By Ramming Andwatering, Lead Up To 50 And For All Lift. , Disposal Of Building Rubbish / Malba / Similar Unserviceable, Dismantled Or Waste Materials By Mechanical Means, Including Loading, Transporting, Unloading To Approved Municipal Dumping Ground Or As Approved By Engineer-In-Charge, Beyond 50 M Initial Lead, For All Leads Including All Lifts Involved.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
36.
Water Resources and Irrigation #11220405 Price Bid
Tender for Excavation In Dumped Stones Or Malba Including Stacking Of Serviceable And Unserviceable Material Separately And Disposal Of Unserviceable Material, Lead Up To 50 M And Lift Up To 1.5 M, Disposed Material To Be Neatly Dressed. , Demolishing Cement Concrete Manually/ By Mechanical Means Including Disposal Of Material Within 50 Meters Lead As Per Direction Of Engineer- In - Charge. Nominal Concrete 1:3:6 Or Richer Mix (I/C Equivalent Design Mix). , Cutting Road And Marking Good The Same Including Supply Of Extra Quantities Of Materials I.E. Aggregate, Moorum Screening, Red Bajri And Labaur Required. Water Bound Macadam , Providing And Laying In Position Ready Mixed Plain Cement Concrete, With Cement Content As Per Approved Design Mix And Manufactured In Fully Automatic Batching Plant And Transported To Site Of Work In Transit Mixer For All Leads, Having Continuous Agitated Mixer, Manufactured As Per Mix Design Of Specified Grade For Plain Cement Concrete Work, Including Pumping Of R.M.C. From Transit Mixer To Site Of Laying And Curing, Xcluding The Cost Of Centering, Shuttering And Finishing, Including Cost Of Curing, Admixtures In Recommended Proportions As Per Is : 9103 To Accelerate/Retard Setting Of Concrete, Improve Workability Without Impairing Strength And Durability As Per Direction Of The Engineer-In-Charge. Note : Excess/Less Cement Used Than Specified In This Item Is Payable/ Recoverable Separately M-10 Grade Plain Cement Concrete (Cement Content Considered @ 220 Kg/Cum) , Providing And Laying Rmc Of M-25 Grade By Using Minimum 330 Kg. Of Cement (43 Grade Opc) Per Cum Of Concrete In Roads/Streets Manufactured In Automatic Rmc Plant Using Coarse Sand And Graded Stone Aggregate Of 20 Mm Nominal Size In Appropriate Proportion As Per Approved Design Criteria Including Transportation To Site In Transit Mixer, Including Cost Of Concrete To Improve Workability Wit Out Impairing Strength And Durability As Per Specification Including Spreading And Compacting Mechanically By Using Needle And Surface Vibrators, Leveling To Required Slops And Camber, Finishing By Contractor/ Expansion, Construction Of Cross/ Longitudinal Joints With Approved Joints Filler And Sealants, Etc. Complete As Per Direction Of Engineer-In-Charge(Cost Of Joint Filler & Sealants Shall Be Paid For Separately Under Relevant Item). Note : The Cement Considered In Rmc M-25 Is 330Kg/Cum. If Any Deviation In Quantity On Lower Side Is Observed Subject To Approval Of Job Mix Formula By Engineer-In-Charge, A Recovery Of Cement @ Rs. 10 Per Kg. Will Be Deducted. Rmc M-25 With Cement Content Less Than 300 Kg/Cum Shall Be Rejected. Excess Cement Used More Than 330 Kg/Cum Will Not Be Paid). , 6. Centering And Shuttering Including Strutting,Propping Etc.And Removal Of Form For: 6(A) Foundations,Footings,Bases Of Columns,Etc.Formass Concrete , 6(B) Walls(Anythickness) Including Attached Pilasters,Butteresses, Plinth And String Courses Etc. , 6 (C )Suspended Floors,Roofs,Landings,Balconies And Access Platform. , Providing And Laying In Position Machine Batched And Machine Mixed Design Mix M-25 Grade Cement Concrete For Reinforced Cement Concrete Work, Using Cement Content As Per Approved Design Mix, Including Pumping Of Concrete To Site Of Laying But Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement, Including Admixtures In Recommended Proportions As Per Is: 9103 To Accelerate, Retard Setting Of Concrete, Improve Workability Without Impairing Strength And Durability As Per Direction Of Engineer-In-Charge.(Note :- Cement Content Considered In This Item Is @ 330 Kg/Cum.Excess/ Less Cement Used As Per Design Mix Is Payable/Recoverable Separately).All Works Upto Plinth Level , Steel Reinforcement For R.C.C.Work Including Straightening,Cutting, Bending,Placing In Position And Bind In Gall Complete Upto Plinth Level. Thermo-Mechanically Treated Bars Of Grade Fe-500D Or More. , Cement Concrete Flooring 1:2:4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate)Finished With A Floating Coat Of Neat Cement,Including Cementslurry,But Excluding The Cost Of Nosingofsteps Etc.Complete. 40Mm Thick With 20Mm Nominal Size Stone Aggregate. , Providing And Laying Non-Pressure Np4 Class (Heavy Duty) Reinforced Cement Concrete Pipes Including Collars / Spigot Jointed With Stiff Mixture Of Cement Mortar In The Proportion Of 1:2 (1 Cement : 2 Fine Sand) Including Testing Of Joints Etc. Complete : 1000 Mm Dia. Reinforced Cement Concrete Pipes (Laying By Manual/Mechanical Means). , Providing And Laying Non-Pressure Np2 Class (Light Duty) Reinforced Cement Concrete Pipes With Collars Jointed With Stiff Mixture Of Cement Mortar In The Proportion Of 1:2 (1 Cement : 2 Fine Sand) Including Testing Of Joints Etc. Complete :300 Mm Dia. Reinforced Cement Concrete Pipe , Constructing Brick Masonry Circular Manhole 1.22 M Internal Dia At Bottom And 0.56 M Dia At Top In Cement Mortar 1:4 (1 Cement :4 Coarse Sand) Inside Cement Plaster 12 Mm Thick With Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) Finished With A Floating Coat Of Neat Cement Foundation Concrete 1:3:6 (1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 40 Mm Nominal Size) And Making Necessary Channel In Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size) Finished With A Floating Coat Of Neat Cement, All Complete As Per Standard Design : 1.68 M Deep With Steel Fibre Reinforced Concrete Cover And Frame (Heavy Duty Hd-20 Grade Designation) 560 Mm Internal Diameter Conforming To I.S. 12592, Total Weight Of Cover And Frame To Be Not Less Than 182 Kg. Fixed In Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size) Including Centering, Shuttering All Complete. (Excavation, Foot Rests And 12 Mm Thick Cement Plaster At The External Surface Shall Be Paid For Separately) : With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5. , Providing And Placing In Position 100 Mm Thick Factory Made Machine Batched & Machine Mixed Precast Reinforced Cement Concrete Rectangular Covers On Drains Of Footpath Of Various Sizes, Of M-25 Grade Cement Concrete For Reinforced Cement Concrete Work, Including Cost Of Centering, Shuttering, Reinforcement Of 8 Mm Dia Tmt Bars Of Fe 500 Grade @ Maximum 100Mm C/C On Both Ways , Neat Cement Punning On Finished Surface, Properly Encased On All Edges With 1.6 Mm Thick , 100 Mm Wide Ms Sheet Duly Painted Over Priming Coat , Reinforcement To Be Welded At Edges With Ms Sheet And Providing 2 Nos. 12 Mm Dia Bar For Hooks Etc I/C Cost Of Cartage, All Leads & Lift, Handling At Site Etc. All Complete As Per Direction Of Engineer-In-Charge. , Filling Available Excavated Earth (Excluding Rock) In Trenches, Plinth, Sides Of Foundations Etc. In Layers Not Exceeding 20Cm In Depth, Consolidatin Geachde Posited Layer By Ramming And Watering,Leadup To50mandliftupto1.5M. , Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement - All Work Up To Plinth Level : 1:2:4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size) , Disposal Of Building Rubbish / Malba / Similar Unserviceable, Dismantled Or Waste Materials By Mechanical Means, Including Loading, Transporting, Unloading To Approved Municipal Dumping Ground Or As Approved By Engineer-In-Charge, Beyond 50 M Initial Lead, For All Leads Including All Lifts Involved.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 5
37.
Public Administrative Department #11214469 AOC
Tender For Annual Plan-Annual Project 2024-25 Mankulam Gp Maintenance Of Puthukkudi Anganwadi No.74,Ward Ix, 206/2024-25-206/2024-25-General Civil Work - Building Maintanance 2 OD245497/2024-2025:Supplying and providing MS dowel bar of size16 mm dia 2m long (1m in rock and 1min concrete) 3 5.2.2:Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up tot floor five level excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3( 1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) 4 5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more 5 5.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete 6 5.9.3:Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform 7 2.8.1:Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil 8 4.1.8:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size) 9 50.6.1.7:Solid block masonry using pre cast solid blocks ( Factory made) of size 40x20x15cm or nearest available size confirming to IS 2185 part I of 1979 for foundation and plinth with thickness 15 cm in : CM 1:6 ( 1 cement : 6 coarse sand ) etc complete 10 10.25.2:Item Shifted to Sub head 14 as item 14.73Item Shifted to head 14 as item 14.74Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works 11 17.9.1:Providing and fixing kitchen sink with C. I brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste complete, including painting the fittings and brackets, cutting and making good the walls wherever required:White glazed fire clay kitchen sink of size 600x450x250 mm 12 13.9.1:Cement plaster 1:3 ( 1 cement : 3 coarse sand) finished with a floating coat of neat cement.12 mm cement plaster 13 13.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) 14 13.44.1:Finishing walls with water proofing cement paint of required shade:New work (Two or more coats applied @ 3.84 kg/10 sqm) 15 50.2.26.1:Filling with contractor own earth (excluding rock) in open areas in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m as per direction of site Engineer-in-charge. 16 16.68:Providing and laying 60 mm thick factory made cement concrete interlocking paver block of M - 30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge. 17 OD235200/2024-2025:Supplying and fixing Granite name board (minimum size 40cmx30cm or nearest)
Contract Date: Jun 03, 2026 Contract Value : 2.43 Lakh
Government Departments No of Bidders 1
38.
Public Administrative Department #11212847 AOC
Tender for Supplying And Laying Of Following Size C Pvc Pipe In Along With All Accessories Like Socket, Bend, Couplers Etc. Conforming To Is:4985:2000, Part Ii Complete With Fitting And Cutting, Jointing Etc..Direct In Ground (50 Cm Below Ground Level) Including Excavation And Refilling The Trench But Excluding Sand Cushioning And Protective Covering Etc., Complete As Required. 25 Mm Dia , Fabrication, Supplying, Installation, Testing And Commissioning Of Bollard Light Having Length 750Mm Of Ms Sheet I/C Making Design By Laser Cutting , As Approved By Engineer In Charge And Welding The Same, With 2 Nos. 10 Watt Warm White 2 Feet Long Led Tube Light Fitting And Having Suitable Arrangement To Accommodate 2 Nos. 10 Watt Warm White 2 Feet Long Led Tube Light , Duly Painted With One Coat Of Primer And Two Coat Pu Paint I/C J-Type Foundation Nut Bolt, But Excluding Foundation Complete As Required. , providing and Fixing Hot Press Sheet Moulded Compound (Smc) Fire Retardant (Temp. Resistance Up To 200 C), Ip 55 Weather Proof Pole Box Of Inner Dimension 300X200x105mm (Ns) And Outer Dimension Of 333X233x150 Mm High Dome Complete With Suitable Arrangement For Fixing Of 4 Nos Of 6 To 32 annual periodical maintenance Single Pole Mcb & 63 Amp. Double Pole Isolator (Mcb/Isolator Excluded) With Neutral Link Duly Shorting On Din Channel With2 Nos Of Ms Clamps With Ss Back Plate Of Suitable Size With Danger Monogram Property Printed On The Cover Etc As Reqd. , Supplying And Fixing 5 A To 32 A Rating, 240/415 V, 10 Ka, C Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.(A) Single Pole , Supplying And Fixing 5 A To 32 A Rating, 240/415 V, 10 Ka, C Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. (B) Single Pole And Neutral , Supply Of Following Size Of Pvc Insulated & Pvc Sheathed Copper Conductor 3 Core Submersible Cable Conforming To Is . 694/210 Etc. As Rqd. 3×2.5 Sqmm With Voltage Grade 1100 Volts. , Supply Of Xlpe Insulated Pvc Sheathed Al. Conductor Armoured Cable 1.1Kv Grade Conforming To Is-7098 Of Following Size:-2C X 10 Sqmm , Earth Work In Excavation By Mechanical Means (Hydraulic Excavator)/ Manual Means Over Areas (Exceeding 30 Cm In Depth, 1.5 M In Width As Well As 10 Sqm On Plan) Including Getting Out And Disposal Of Excavated Earth Lead Upto 50 M And For All Lift, As Directed By Engineer-In-Charge. All Kinds Of Soil , Centering And Shuttering With 12Mm Thick Shuttering Plywood Confirming To Is 4990:2011 And Removal Of Form At All Heights. Plywood Will Be Supported On Lock Bars. Suspended Floors, Roofs, Landings, Balconies And Access Platform. Suspended Floors, Roofs, Landings, Balconies And Access Platform. , Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level : 1:3:6 (1 Cement : 3 Coarse Sand (Zone-Iii) Derived From Natural Sources : 6 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources) , Earthing With G.I. Earth Pipe 4.5 Metre Long, 40 Mm Dia Including Accessories, And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Etc. With Charcoal/ Coke And Salt As Required , Earthing With G.I. Earth Plate 600 Mm X 600 Mm X 6 Mm Thick Including Accessories, And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Of 2.7 Metre Long Etc. With Charcoal/ Coke And Salt As Required. , Providing And Laying Earth Connection From Earth Electrode With 6 Swg Dia G.I. Wire In 15 Mm Dia G.I. Pipe From Earth Electrode Including Connection With G.I. Thimble Excavation And Re-Filling As Required. , Supplying And Fixing Of Light Class Gi Pipe Of 50 Mm Dia (Nominal) 3 Meters Length Along The Pole For Protection Of Under Ground Cable As Required. , Excavation Of The Cable Trenches In Hard Rock Not Exceeding 1.5 Meters In Width, And Lift Upto 1.5 Meters, Including Getting Out The Excavated Soil And Disposal Of Excavated Soil As Directed Within A Lead Of 50 Meters. , Supplying And Laying Of Following Size Dwc Hdpe Pipe Isi Marked Along With All Accessories Like Socket, Bend, Couplers Etc. Conforming To Is 14930, Part Ii Complete With Fitting And Cutting, Jointing Etc.In The Existing Trench, Complete As Required. 63 Mm Dia (Od-63 Mm & Id-51 Mm Nominal) , Supplying And Laying Of Following Size Dwc Hdpe Pipe Isi Marked Along With All Accessories Like Socket, Bend, Couplers Etc. Conforming To Is 14930, Part Ii Complete With Fitting And Cutting, Jointing Etc..Direct In Ground (75 Cm Below Ground Level) Including Excavation And Refilling The Trench But Excluding Sand Cushioning And Protective Covering Etc., Complete As Required. 63 Mm Dia (Od-63 Mm & Id-51 Mm Nominal) , Laying Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Following Size In The Existing Rcc/ Hume/ Metal Pipe As Required. Upto 35 Sq. Mm , Laying Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Following Size In The Existing Masonry Open Duct As Required. Upto 35 Sq. Mm
Contract Date: Jun 11, 2026 Contract Value : 61.00 Lakh
Local Bodies No of Bidders 4
40.
Power #11209663 AOC
Bids Are Invited For Repair, Maintenance, And Installation Of Plant/ Systems/Equipments (Version 2) - 3995405; 3995405; Service Provider-Providing And Fixing G.I. Pipes Complete With G.I. Fittings Including Trenching And Refilling Etc.External Work. 15 Mm Dia. Nominal Bore Providing And Fixing G.I. Pipes Complete With G.I. Fittings Including Trenching And Refilling Etc.External Work20 Mm Dia. Nominal Bore Providing And Fixing G.I. Pipes Complete With G.I. Fittings Including Trenching And Refilling Etc.External Work 25 Mm Dia. Nominal Bore Providing And Fixing G.I. Pipes Complete With G.I. Fittings Including Trenching And Refilling Etc.External Work 32 Mm Dia. Nominal Bore Providing And Fixing G.I. Pipes Complete With G.I. Fittings Including Trenching And Refilling Etc.External Work 40 Mm Dia. Nominal Bore Providing And Fixing G.I. Pipes Complete With G.I. Fittings Including Trenching And Refilling Etc.External Work 50 Mm Dia. Nominal Bore Same As Above But For Internal Work (Exposed On Wall) 15 Mm Dia. Nominal Bore Same As Above But For Internal Work (Exposed On Wall) 20 Mm Dia. Nominal Bore Same As Above But For Internal Work (Exposed On Wall) 25 Mm Dia. Nominal Bore Same As Above But For Internal Work (Exposed On Wall) 32 Mm Dia. Nominal Bore Same As Above But For Internal Work (Exposed On Wall) 40 Mm Dia. Nominal Bore Same As Above But For Internal Work (Exposed On Wall) 50 Mm Dia. Nominal Bore Providing & Fixing Full Way Stop Cock/G.M. Gate Valve Of Following Dia With Wheel, I.S.I. Mark Heavy Duty. Including Supply Of All Materials Labours, T&P Required For Proper Completion. 15 Mm Dia. Nominal Bore Providing & Fixing Full Way Stop Cock/G.M. Gate Valve Of Following Dia With Wheel, I.S.I. Mark Heavy Duty. Including Supply Of All Materials Labours, T&P Required For Proper Completion. 20 Mm Dia. Nominal Bore Providing & Fixing Full Way Stop Cock/G.M. Gate Valve Of Following Dia With Wheel, I.S.I. Mark Heavy Duty. Including Supply Of All Materials Labours, T&P Required For Proper Completion. 25 Mm Dia. Nominal Bore Providing And Fixing Ball Valve (Brass) Of Approved Quality, High Or Low Pressure, With Plastic Floats Complete :15 Mm Nominal Bore Providing And Fixing Brass Ferrule With C.I. Mouth Cover Including Boring And Tapping The Main :15 Mm Nominal Bore Providing And Fixing Unplasticised P.V.C. Connection Pipe With Ptmt Nuts, Collar And Bush Of Approved Quality And Colour. 15 Mm Nominal Bore With 45 Cm Length. Providing And Placing On Terrace (At All Floor Levels) Polyethylene Water Storage Tank Isi : 12701 Marked With Cover And Suitable Locking Arrangement And Making Necessary Holes For Inlet, Outlet And Overflow Pipes But Without Fittings And The Base Support For Tank Providing And Fixing Brass Bib Cock Of Approved Quality :15 Mm Nominal Bore Supply And Fixing Of 15Mm Dia Ci/P.V.C. Bib Cock Including Replacing Of Old Bib Cock Complete. Providing & Fixing Of 110 Mm P.V.C. Pipe 6 Kg/Cm2 Specials Such As Tee, Bend, Socket, Elbow Etc. Including Cutting Excavation Of Trenches Its Back Filling After Testing The Pipe Line, Watering, Ramming Etc. Complete Including Disposal Of Surplus Earth From The Site Up To 100 Metre As Per Direction Of Engineer-In-Charge As Required For Proper Completion Of Work. Providing & Fixing 15 Mm Dia C.P. Pillar Cock Of Approved Make Including Cost Of All Materials, Labours T&P Etc. Required For Proper Completion Of Work. Providing & Fixing Suitable P.V.C. Washer In Bib/Stop/Pillar Cock, Including Cost Of Washer, Labour T&P Etc. Providing And Fixing G.I. Union 15 Mm Nominal Bore Each Union In Existing G.I. Pipe Line, Cutting And Threading The Pipe And Making Long Screws Including Excavation, Refilling The Earth Or Cutting Of Wall And Making Good The Same Complete Wherever Required :15 Mm Nominal Bore. Same As Above But For G.I. Tee, Socket, Elbow, Bend Etc. Upto 50Mm Dia Providing And Fixing White Vitreous China Water Closet Squatting Pan (Indian Type) But Orissa Pattern W.C. Pan Of Size 580X440 Mm Providing And Fixing White Vitreous China Squatting Plate Urinal With Integral Rim Longitudinal Flush Pipe. Providing And Fixing White Vitreous China Wash Basin Including Making All Connections But Excluding The Cost Of Fittings :Flat Back Wash Basin Of Size 550X400Mm. Providing And Fixing Ptmt Waste Coupling For Wash Basin And Sink, Of Approved Quality And Colour.Waste Coupling 38 Mm Dia Of 83 Mm Length And 77Mm Breadth, Weighing Not Less Than 60Gms. Providing And Fixing P.V.C. Low Level Flushing Cistern With Manually Controlled Device (Handle Lever) Conforming To Is : 7231, With All Fittings And Fixtures Complete.10 Litre Capacity - White Providing And Fixing 600X450 Mm Beveled Edge Mirror Of Superior Glass (Of Approved Quality) Complete With 6 Mm Thick Hard Board Ground Fixed To Wooden Cleats With C.P. Brass Screws And Washers Complete. Providing & Fixing :100 Mm Sand Cast Iron Grating For Gully Trap. Repair Of Leakage In G.I./C.I. Pipe Line Of Following Dia. Including Necessary Excavation/Dismantling Relaying Of Pipe And Refilling Of Trenches Etc. Including Replacement Of Nuts, Bolts, Washer And Filling Etc. Complete 20 Mm To 40 Mm Dia Pipe Repair Of Leakage In G.I./C.I. Pipe Line Of Following Dia. Including Necessary Excavation/Dismantling Relaying Of Pipe And Refilling Of Trenches Etc. Including Replacement Of Nuts, Bolts, Washer And Filling Etc. Complete 50 Mm To125 Mm Dia Pipe Earth Work In Excavation By Mechanical Means (Hydraulic Excavator)/Manual Means Over Areas (Exceeding 30 Cm In Depth, 1.5 M In Width As Well As 10 Sqm On Plan) Including Getting Out And Disposal Of Excavated Earth Lead Upto 50 M And Lift Upto 1.5 M, As Directed By Engineer-In-Charge. 2.6.1 All Kinds Of Soil Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level .1:4:8 (1 Cement : 4 Coarse Sand : 8 Graded Stone Aggregate 40 Mm Nominal Size). Same As Above But C.C.1:2:4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size) Providing Half Brick Masonry With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 In Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) In Superstructure For Closing Cavity 5 To 7.5 Cm Wide In Cavity Wall Complete With 10 Cm / 11.4 Cm Wide Bitumen Felt Type 3 Grade 1. Brick Work With Non Modular Fly Ash Lime Bricks (Falg Bricks) Conforming To Is:12894, Class Designation 10 Average Compressive Strength In Super Structure Above Plinth Level Up To Floor V Level In :Cement Mortar 1:6 (1 Cement : 6 Coarse Sand) 12 Mm Cement Plaster In Fine Sand Of Mix With 1:6 (1 Cement: 6 Fine Sand) Cement Concrete Flooring 1:2:4. With 40 Mm Thick With 20 Mm Nominal Size Stone Aggregate. Attending Of Petty Maintenance Service Like Plumbing, Welder, Mason And Carpenter Services With One No. Plumber/Welder/Mason/Carpenter With One No. Helper Per Hour. Making Connection Of G.I. Distribution Branch With G.I. Main Of Following Sizes By Providing And Fixing Tee, Including Cutting And Threading The Pipe Etc. Complete :25 To 40 Mm Nominal Bore.Providing And Fixing Brass Ferrule With C.I. Mouth Cover Including Boring And Tapping The Main.15 Mm Nominal Bore Providing And Fixing C.P. Brass Stop Cock (Concealed) Of Standard Design And Of Approved Make Conforming To Is:8931.15 Mm Nominal Bore. Providing & Fixing Bottle Trap Of C.P. Brass Including Cost Of All Materials, Labour, T&P Etc. All Complete. Providing And Fixing Kitchen Sink With C.I. Brackets, C.P. Brass Chain With Rubber Plug, 40 Mm C.P. Brass Waste Complete, Including Painting The Fittings And Brackets, Cutting And Making Good The Walls Wherever Required .White Glazed Fire Clay Kitchen Sink Of Size 600X450X250 Mm. Providing And Fixing Soil, Waste And Vent Pipes Of 100 Mm Dia. Centrifugally Cast (Spun) Iron Socket & Spigot (S&S) Pipe As Per Is: 3989. Same As Item Above Above But For 75 Mm Dia. Centrifugally Cast (Spun) Iron Socketed Supply & Fixing C.P. Brass Bib Cock Heavy Quality 15 Mm Dia (400 Gms) Isi Mark Including Supply Of All Material, Labour And T&P Etc. Required For Proper Completion Of Work. Providing And Fixing Bend Of Required Degree With Access Door, Insertion Rubber Washer 3 Mm Thick, Bolts And Nuts Complete Of 100 Mm Dia. With Sand Cast Iron S&S As Per Is 3989 Same As Item Above Above But For 75 Mm Dia And .Sand Cast Iron S&S As Per Is- 3989 Providing Lead Caulked Joints To Sand Cast Iron/Centrifugally Cast (Spun) Iron Pipes And Fittings Of Diameter Of 100 Mm. Same As Item Above Above But For 75 Mm Dia. Same As Item Above Above But For 50 Mm Dia. Providing And Fixing Trap Of Self Cleansing Design With Screwed Down Or Hinged Grating With Or Without Vent Arm Complete, Including Cost Of Cutting And Making Good The Walls And Floors .100 Mm Inlet And 100 Mm Outlet.Sand Cast Iron S&S As Per Is: 1729. Cleaning Of Septic Tank Including Disposal Of Waste Outside The Area As Per Direction Of The Engineer Incharge Including Cost Of Removing Septic Tank Cover And Replacing Cover In Its Position Including Cost Of All Labour T&P Etc. Required For Proper Completion Of Work. Same As Above Item But For Inspection Chamber. Repair & Adustment Of Aluminum Doors And Windows For Proper Functioning By Skilled Mechanic Including All Labour T&P Etc. Required For Proper Completion Work. Supply & Fixing Of Brass Polised Hydraulic Door Closure Of Standar Size And Approved Quality In Door Shutter Including Cost Of All Providing And Fixing Double Action Hydraulic Floor Spring Of Approved Brand And Manufacture Conforming To Is : 6315, Having Brand Logo Embossed On The Body / Plate With Double Spring Mechanism And Door Weight Upto 125 Kg., For Doors, Including Cost Of Cutting Floors , Embedding In Floors As Required And Making Good The Same Matching To The Existing Floor Finishing And Cover Plates With Brass Pivot And Single Piece M.S. Sheet Outer Box With Slide Plate Etc. Complete As Per The Direction Of Engineer-In-Charge.With Stainless Steel Cover Plate Minimum 1.25 Mm Thickness. Renewing Glass Panes, With Putty And Nails Wherever Necessary Including Racking Out The Old Putty:Float Glass Panes Of Thickness 5.5 Mm Same As Item Above But 4 Mm Thich Float Glass Panes. Filling The Gap In Between Aluminium Frame & Adjacent Rcc/ Brick/ Stone Work By Providing Weather Silicon Sealant Over Backer Rod Of Approved Quality As Per Architectural Drawings And Direction Of Engineer-In-Charge Completeupto 5Mm Depth And 5 Mm Width. Providing & Fixing Fully Glazed Anodized Aluminum Fixed Glazing With Hindalco Or Equivalent Extruded Standard Sections Of Various Thickness Show In Extruded Standard Sections Of Various Thickness Shown In Drawing Joints Mitered And Jointed As Shown In Drawing Including Providing And Fixed Of 5.5 Mm Thick Glass With Neoprene Beading All Round. The Minimum Thickness Of Anodizing On All Aluminum Sections Should Be 20 Micron With A (+) 2 Microns Tolerance. The Rate Should Include The Cost Of Fixing Of All Frame To Teak Wood Frame Or With Masonry/Rb/Rcc Structure By There Of Starting From 100 Mm Above The Bottom In Vertical Member Excluding Cost Of Teak Wood Frame. But Including Cost Of All Other Materials, Labour T&P Etc. Complete Required For Proper Completion Of Work. Same As Item Above But For Openable Window Portion As Shown In Drawings, Including Providing & Fixing Aluminum Hinges Of Heavy Quality And All Other Fitting Like Concealed Tower Bolts Handles Etc. As Per Direction Of Engineer-In-Charge Required For Proper Completion Of Work. Same As Item Above But For Openable Gate/Doors Portion As Shown In Drawings Including Providing And Fixing Pivots Of Heavy Quality And All Other Fittings Like Concealed Approved Tower Bolts, Bush Plate (As Shown In Drawing) And Approved Standard Brass Body With Brass Components 6 Levers Heavy Duly Concealed Lock Etc. Required For Proper Completion Of Work. Providing & Fixing Top Cover Of Rolling Shutters Structural Steel Work Riveted, Bolted Or Welded In Built Up Sections, Trusses And Framed Work, Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer All Complete. Providing And Laying Ceramic Glazed Floor Tiles 300X300 Mm (Thickness To Be Specified By The Manufacturer) Of 1St Quality Conforming To Is : 15622 Of Approved Make In All Colours, Shades, Except White, Ivory, Grey, Fume Red Brown Laid On 20Mm Thick Bed Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) Including Pointing The Joints With White Cement And Matching Pigments Etc Complete. Providing Corrugated G.S. Sheet Roofing Including Vertical/Curved Surface Fixed With Polymer Coated J Or L Hooks, Bolts And Nuts 8 Mm Diameter With Bitumen And G.I. Limpet Washers Or With G.I. Limpet Washers Filled With White Lead And Including A Coat Of Approved Steel Primer And Two Coats Of Approved Paint On Overlapping Of Sheets Complete (Up To Any Pitch In Horizontal/ Vertical Or Curved Surfaces) Excluding The Cost Of Purlins, Rafters And Trusses And Including Cutting To Size And Shape Wherever Required.1.00Mm Thick With Zinc Coating Not Less Than 275Gm/M². Providing Ridges Or Hips Of Width 60 Cm Overall Width Plain G.S. Sheet Fixed With Polymer Coated J. Or L Hooks, Bolts And Nuts 8 Mm Dia. G.I. Limpet And Bitumen Washers Complete. 0.80Mm Thick With Zinc Coating Not Less Than 275Gm/M². Providing Non-Asbestos High Impact Polypropylene Reinforced Cement 6Mm Thick Corrugated Sheets (As Per Is: 14871) Roofing Up To Any Pitch And Fixing With Polymer Coated J, Or L Hooks, Bolts And Nuts 8Mm Dia. G.I. Plain And Bitumen Washers Or With Self Drilling Fastener And Epdm Washers Etc. Complete (Excluding The Cost Of Purlins, Rafters And Trusses), Including Cutting Sheets To Size And Shape Wherever Required. Providing Jack Hammer With Compressor Its Lead And Operator For Making Hole In Slab And Breaking R.C.C. And Exposing Existing Reinforcement And J.C.B Machine With Driver/Operator Fuel Hire Etc. Complete. Providing And Fixing 3Mm Thick Translucent White Acrylic Plastic Sheets Of Approved Quality In False Ceiling Or Window Pan Up To Any Elevation. Providing And Fixing 6 Mm. Thick Gympsum Board In False Ceiling With Beading And All Including Fixture Where Ever As Required Including Supply All Materials, Labours, T&P Etc. Required For Proper Completion Of Work. Reinforcement For R.C.C Work Including Straightening, Cutting Bending, Placing In Position And Binding All Complete (Cold Twisted Bars). Providing And Grouting With Convextra G.P.- 2 Of Standard Quality Approved By Engineer In - Charge Including Chipping Of Rcc And Including All Labors, T&P Etc. Complete. Installation & Running Of 5 Hp /7.5 Hp Elctric/Diesel Engine Motor Pump Set With Suction Of 5 Meter Depth & Delivery Pipe Up To The Distance Of 70 Meter In Near By Pit Including Cost Of All Hire Charges Of Motor Pump Set, Operator And Fuel Etc. Complete As Pr Direction Of Engineer In Charge. Cartage Of Grass/Malwa By Tractor Trally Upto A Distance Of 1 Km From Periphery Of Area Cleared, Including Cost Of All Labour, T&P Etc. Such As Loading Unloading & Cartage, Tractor Trally, Driver, Fuel Required For Proper Comlplletion Of Work. Reinforced Cement Concrete Work In Walls (Any Thickness), Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc. Up To Floor Five Level Excluding Dismantling & Relaying Of Old G.I Pipe With Supply And Fixing Of Approved G.I Fitting As Per Required For The Following Base,Including Threading Of Pipe It Required,Including Cutting And Making Good Wall. 15 Mm To 20 Mm Dia. Dismantling & Relaying Of Old G.I Pipe With Supply And Fixing Of Approved G.I Fitting As Per Required For The Following Base,Including Threading Of Pipe It Required,Including Cutting And Making Good Wall. 40 Mm To 80 Mm Dia. Providing And Fixing Bright Finished Brass/Aluminium Hanging Type Floor Door Stopper With Necessary Screws Of Approved Brand , Etc. Complete. Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form Work For All Type Of Work Upto 52 Mts Floor As Per Specification. Providing And Fixing 110X25 Mm Outer Dia. Pvc Saddle Or 110Mm Outer Dia Pvc Including Rubber Ring. Providing And Fixing P.V.C. Waste Pipe For Sink Or Wash Basin Including P.V.C. Waste Fittings Complete For Semi Regid Or Flexibel Upto 40 Mm Dia. Providing Wood Work In Frames Of Doors, Windows, Clerestory Windows And Other Frames, Wrought Framed And Fixed In Position With Hold Fast Lugs Or With Dash Fasteners Of Required Dia & Length ( Hold Fast Lugs Or Dash Fastener Shall Be Paid For Separately).Sal Wood Or Teak Wood(As Per Direction Of Engineer In Charge). Providing And Fixing Partition Upto Ceiling Height Consisting Of G.I. Frame And Required Board Including Providing And Fixing Of Frame Work Made Of Special Section Power Pressed/ Roll Form G.I. Sheet With Zinc Coating Of 120 Gms/Sqm(Both Side Inclusive), Consisting Of Floor And Ceiling Channel 50Mm Wide Having Equal Flanges Of 32 Mm And 0.50 Mm Thick, Fixed To The Floor And Fixed To The Studs Using Metal To Metal Flat Head Screws, Including Jointing And Finishing To A Flush Finish With Recommended Jointing Compound, Jointing Tape, Angle Beads At Corner (25 Mm X 25 Mm X 0.5 Mm), Joint Finisher And Two Coats Of Primer Suitable For Board As Per ManufactureS Specification And Direction Of Engineer In Charge All Complete. As Per Specification Of Dsr. Providing And Fixing 40 Mm Thickacid And/Or Alkali Resistant Tiles Of Approved Make And Colour Using Acid And/Or Alkali Resisting Mortar Bedding, And Joints Filled With Acid And/Or Alkali Resisting Cement Also Includs The Cost Of 10 Mm Thick Acid Proof Base/Lining As Per Is : 4457, Complete As Per The Direction Of Engineer-In- Charge.In Dado/Skirting On 12 Mm Thick Mortar 1:4 (1 Acid Proof Cement : 4 Coarse Sand) Acid And Alkali Resistant Tile. Supply Of 100 Mm Long 15 Mm G.I. Nozzle Including Cutting Holes In Rcc Slab, Column,Floor And Beam Including Its Fixing With Cement Mortar Including All Labour, T&P And Material Etc Complete As Per Direction Of Engineer-In-Charge. Pressure Grouting Of Crackes Honey Comb In Concrete Surface Expansion Joints Or Where Ever Required With Cement Grout Of Ratio One Part Of Cement, Four Parts Of Water And 3% Water Proofing Cicco No.3 Compound (Liquids) With The Help Of Grout Pump Of Appropriate Pressure Excluding Cost Of Fixing G.I. Nozzles Complete. As Per Engineer-In- Charge . Epoxy Adhesive Providing And Fixing Aluminum U Beading Of Required Size To Pre-Laminated/ Flush Door Shutter, Including Fixing Etc. Complete As Per Direction Of Engineer-In-Charge. Kg 435.10 Finishing With Epoxy Paint (Two Or More Coats) At All Locations Prepared And Applied As Per ManufacturerS Specifications Including Appropriate Priming Coat, Preparation Of Surface, Etc. Complete. On Concrete Work 12 Mm Thick Marine Plywood Conforming To Is: 710 Providing And Fixing 10 Mm Thick Acid And/Or Alkali Resistant Tiles Of Approved Make And Colour Using Acid And/Or Alkali Resisting Mortar Bedding, And Joints Filled With Acid And/Or Alkali Resisting Cement As Per , Complete As Per The Direction Of Engineer-In- Charge In Dado/Skirting On 12 Mm Thick Mortar 1:4 (1 Acid Proof Cement : 4 Coarse Sand) Acid And Alkali Resistant Tile Sqm 1607.70 Providing And Laying Vitrified Floor Tiles In Different Sizes (Thickness To Be Specified By The Manufacturer) With Water Absorption Less Than 0.08% And Conforming To Is: 15622, Of Approved Make, In All Colours And Shades, Laid On 20Mm Thick Cement Mortar 1:4 (1 Cement : 4 Coarse Sand), Jointing With Grey Cement Slurry @ 3.3 Kg/ Sqm Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete Size Of Tile 600X600 Mm Sqm Providing And Fixing G.I. Union In Existing G.I. Union 50 Mm Nominal Bore Each Providing And Fixing G.I. Union In Existingg.I. Union 25 Mm Nominal Bore Each Providing And Fixing White Vitreous China Pedestal Type (European Type/ Wash Down Type) Water Closet Pan. Each 2276.95 Providing And Fixing 8 Mm Dia C.P. / S.S. Jet With Flexible Tube Upto 1 Metre Long With S.S. Triangular Plate To Eureopean Type W.C. Of Quality And Make As Approved By Engineer - In - Charge. Each 297.55 12.5 Mm Thick Fully Perforated Gypsum Board Tile Made From Plasterboard Having Glass Fibre Conforming To Is: 2095 Part I, Of Size 595X595 Mm, Having Perforation Of 9.7X9.7 Mm At 19.4 Mm C/C With Center Borders Of 48 Mm And The Side Borders Of 30 Mm, Backed With Non Woven Tissue On The Back Side, Having An Nrc (Noise Reduction Coefficient) Of 0.79, With 50 Mm Resin Bonded Glass Wool Backing. Providing And Fixing Kitchen Sink With C.I. Brackets, C.P. Brass Chain With Rubber Plug, 40 Mm C.P. Brass Waste Complete, Including Painting The Fittings And Brackets, Cutting And Making Good The Walls Wherever Required: White Glazed Fire Clay Kitchen Sink Of Size 600X450X 250 Mm Providing And Fixing Ptmt Towel Rail Complete With Brackets Fixed To Wooden Cleats With Cp Brass Screws With Concealed Fittings Arrangement Of Approved Quality And Colour. 600 Mm Long Towel Rail With Total Length Of 645 Mm, Width 78 Mm And Effective Height Of 88 Mm, Weighing Not Less Than Providing And Fixing Ptmt, Push Cock Of Approved Quality And Colour. 15 Mm Nominal Bore, 98 Mm Long, Weighing Not Less Than 75 Gms Providing And Fixing 18 Mm Thick Gang Saw Cut, Mirror Polished, Premoulded And Prepolished, Machine Cut For Kitchen Platforms, Vanity Counters, Window Sills, Facias And Similar Locations Of Required Size, Approved Shade, Colour And Texture Laid Over 20 Mm Thick Base Cement Mortar 1:4 (1 Cement : 4 Coarse Sand), Joints Treated With White Cement, Mixed With Matching Pigment, Epoxy Touch Ups, Including Rubbing, Curing, Moulding And Polishing To Edges To Give High Gloss Finish Etc. Complete At All Levels.Granite Of Any Colour And Shade 8.2.2.2 Area Of Slab Over Providing And Fixing Plastic Seat Cover With Lid For Pedestal Type W.C.Pan Complete : White Plastic Seat With Lid Providing And Fixing On Wall Face Unplasticised - Pvc Moulded Fittings/ Accessories For Unplasticised Rigid Pvc Rain Water Pipes Conforming To Is : 13592 Type A, Including Jointing With Seal Ring Conforming To Is : 5382, Leaving 10 Mm Gap For Thermal Expansion. Bend 87.5° 110 Mm Bend Neat Cement Punning Fencing With Angle Iron Post Placed At Required Distance Embedded In Cement Concrete Blocks, Every 15Th Post, Last But One End Post And Corner Post Shall Be Strutted On Both Sides And End Post On One Side Only And Provided With Horizontal Lines And Two Diagonals Interwoven With Horizontal Wires, Of Barbed Wire Weighing 9.38 Kg Per 100 M (Minimum), Between The Two Posts Fitted And Fixed With G.I. Staples, Turn Buckles Etc. Complete. (Cost Of Posts, Struts, Earth Work And Concrete Work To Be Paid For Separately). Payment To Be Made Per Metre Cost Of Total Length Of Barbed Wire Used. 16.18.1 With G.I. Barbed Wire Metre Providing And Fixing G.I. Union In Existingg.I. Union 15 Mm Nominal Bore Each Dismantaling By Electrical Hilti Including Cost Of Gst 18% Pr 1100069168 Rfq 6000011061
Contract Date: Ref. Documents Contract Value : 44.22 Lakh
Government Departments No of Bidders 5
Uttar Pradesh View Result →
41.
Defence #11200251 Technical Bid
Tender For Provision Of Certain Sanctioned Works Under Ge South Bathinda At Bathinda Mil Stn.- 1 Surface Excavation N.Exc (Not Exceeding) 30 Cm Deep And Averaging 15Cm Deep And Getting Out And Getting Out In Soft / Loose Soil Complete All As Specified & Directed. 2 Removing Excavated Material Exc 1.50 Km N Exc. 5 Km And Depositing Where Directed At A Level N Exc. 1.5 M Above The Starting Point Complete All As Specified And As Directed. 3 Excavation In Trenches Not Exceeding 1.5 Meter Wide And Not Exceeding 1.5 Meter Depth For Foundation Etc Or For Shafts , Wells, Cesspits, Manholes , Septic Tank, For Laying Of Cables , Laying Of Pipes Not Exceeding 10 Sqm On Plan And Not Exc 1.5 Meter Depth And Getting Out In Soft/Loose Soil Etc Complete All As Specified And As Directed By Engineer-In- Charge. 4 Material And Labour For Cement Concrete 1:4:8 , Type D-2 Using 40 Mm Graded Stone Aggregate As In Foundation Filling And Mass Concrete Complete All As Specified And As Directed By Engineer-In-Charge. 5 Material And Labour For Rcc M-25 (Design Mix) Using 20 Mm Graded Stone Aggregates As In Foundations, Including Rafts, Footings, Foundation Beams; Plinth Beams; Bases For Columns, Etc.; Basement Slabs, Under-Reamed Piles And Mass Concrete Complete All As Specified And As Directed By Engineer-In-Charge. Note : Reinforcement And Form Work Shall Be Measured And Paid For Separately Under Appropriate Item Of This Schedule. 6 Material And Labour For Rcc M-25 (Design Mix) Using 20 Mm Graded Stone Aggregates As In Columns, Pillars, Piers, Posts And Struts Complete All As Specified And As Directed By Engineer-In-Charge. Note : Reinforcement And Form Work Shall Be Measured And Paid For Separately Under Appropriate Item Of This Schedule. 7 Material And Labour For Rcc M-25 (Design Mix) Using 20 Mm Graded Stone Aggregates As In Beams, Cantilevers, Bressummers, Lintels Over 1.5 M Span And The Like Etc Complete All As Specified And As Directed By Engineer-In-Charge. Note : Reinforcement And Form Work Shall Be Measured And Paid For Separately Under Appropriate Item Of This Schedule. 8 Material And Labour For Rcc M-25 (Design Mix) Using 20Mm Graded Stone Aggregate As In Slabs Supported On Walls, Beams And Columns In Floors,Roofs, Landings, Balconies,Canopies, Deck Slabs And In Shelves And The Like Complete All As Specified And As Directed By Engineer-In-Charge.Note : Reinforcement And Form Work Shall Be Measured And Paid For Separately Under Appropriate Item Of This Schedule. 9 Material And Labour For Formwork Of Sides Of Concrete Foundations, Footings, Bases Of Columns, Raft And Raft Beams, Sides And Soffits (If Any) Of Foundation And Plinth Beams; And Similar Work; Vertical Or To Batter On Rough Finished Flat Surfaces Of Concrete Complete All As Specified And As Directed By Engineer-In-Charge. 10 Material And Labour For Formwork In Square,Reactangular Or Polygonal On Rough Finished Surface Of Concrete To Sides Of Pillars, Posts, Struts, Piers, Columns And Stanchions Complete All As Specified And As Directed By Engineer-In-Charge. 11 Material And Labour For Formwork To Sides And Soffits Of Floor Or Roof Beams, Beam Haunchings, Girders, Bressummers, Lintels, Cantilevers, Shelves Including Supports, Overhangs, Etc. Also Splays Between Floors And Beams, Etc. On Rough Finished Flat Surfaces Of Concrete Complete All As Specified And As Directed By Engineer-In-Charge. 12 Material And Labour For Formwork To Soffits Of Suspended Slabs Such As Roof Slab, Floor Slabs, Landings And Similar Work Not Exceeding 200 Mm Thick (Horizontal Or Sloping) On Rough Finished Flat Surfaces Of Concrete Complete All As Specified And As Directed By Engineer-In-Charge. 13 Material And Labour For Formwork To Edges Of Concrete Flats, Treads, Breaks In Floors,Window Cills, Concrete Rail Ings, Openings In Concrete Walls, Floor And Roofs Not Exceeding 20Cm Wide And Sides Of Rcc/Pcc Bands In Walls, Horizontal Or Sloping And Similar Work Exceeding 10 Cm But Not Exceeding 20Cm Wide On Rough Finished Surfaces Of Concrete Complete All As Specified And As Directed By Engineer-In-Charge. 14 Material And Labour For Mild Steel Tmt Bars 10Mm Dia And Over Cut To Length Bent To Shape, Required Including Cranking, Bending Spirally For Hoping For Columns, Hooking Ends And Binding With Mild Steel Wire (Annealed) Not Less Than 0.9Mm Dia Including Making Of Rungs, Handles Etc Complete All As Specified And As Directed By Engineer-In-Charge. (Note : Weight Of Binding Wire Shall Not Be Considered For Measurement And Payment Purpose.) 15 Material And Labour For Mild Steel Tmt Bars 6Mm To 8Mm Dia Cut To Length Bent To Shape, Required Including Cranking, Bending Spirally For Hoping For Columns, Hooking Ends And Binding With Mild Steel Wire (Annealed) Not Less Than 0.9Mm Dia Including Making Of Rungs, Handles Etc Complete All As Specified And As Directed By Engineer-In-Charge. (Note : Weight Of Binding Wire Shall Not Be Considered For Measurement And Payment Purpose.) 16 Demolition Of Brick Work Or Stone / Boulder Masonry, Built In Cement Mortar Or Cement Lime Mortar Including All Quoins, Arches, Pillars, Etc, In Any Description Complete All As Specified And As Directed By Engineer-In-Charge. 17 Material And Labour For Brick Work With Sub Class ‘B’ Bricks Straight Or Curved On Plan Exceeding 6.0M Mean Radius Built In Cement Mortar 1:6 Complete All As Specified And As Directed By Engineer-In-Charge. 18 Material And Labour For Brick Work With Fly Ash Bricks Straight Or Curved On Plan Exceeding 6.0M Mean Radius Built In Cement Mortar 1:6 Complete All As Specified And As Directed By Engineer-In-Charge. 19 Material And Labour Brick Work With Sub Class ‘B’ Old Size Burnt Clay Bricks Straight Or Curved On Plan Exceeding 6 Metre Mean Radius Built In Cement Mortar 1:6, Complete All As Specified And As Directed By Engineer-In-Charge . 20 Material And Labour For Brick Work With Fly Ash Old Size Bricks, Straight Or Curved On Plan To Any Radius In Half Brick Walls Built In Cement Mortar 1:4 Complete All As Specified And As Directed By Engineer-In-Charge. 21 Demolition Of Cement Concrete (Unreinforced) In Ground Floor And Paving Not Exceeding 15Cm Thickness Below Or Above Ground Level Of Any Description And In Any Position Including Removing Rubbish Material From Building And Thrown In Low Lying Empty Area (As Per Direcction Of Age/Je) At Any Distance Upto 500 Metres From The Site Complete All As Specified And As Directed By Engineer-In-Charge 22 Material & Labour For Cement Concrete 1:3:6 Type C-2 Using 40 Mm Graded Stone Aggregate For Foundations, Fillings & Mass Concrete Complete All As Specified And As Directed By Engineer-In-Charge. 23 Material And Labour For Cement Concrete (1:5:10), Type E-2 Using 40 Mm Graded Stone Aggregate As In Filling Of Sunken Floors Complete All As Specified And As Directed By Engineer-In-Charge. 24 Demolition Of Concrete Of Any Description And In Any Position Not Otherwise Specifically Provided Complete All As Specified And Directed. 25 Material And Labour For Waterproofing Treatment To Sunken Floor Using Acrylic Based Multipurpose Polymer. The Treatment Shall Be Carried Out As Per Manufactures Specification. The Treatment Shall Be Include Of The Following Elements Also: 1. Surface Preparation Of Substrate By Removing All Traces Of Contaminates, Loose And Friable Particles, Cement Laitance Oils And Grease, Water Repellent Coatings Etc2. Injection Grouting Using Cementitious Grout If Required. The Payment For Injection Grouting Shall Be Made Separately Etc3. Repair To The Substrate, Filling Of Blow Holes/Voids And Surface Leveling Using Appropriate Products Specified By The Manufacture.4. All Intersections Of Horizontal And Vertical Surface Should Be Profiled With A Mortar Fillet Of Minimum 25Mm X 25Mm.5. The Moisture Content Of The Substrate Shall Be Checked Before Application Of First Coat At Water Proof Coating At The Rate Of 200 G/M2 Followed Brush Topping At 450G/M2 Per Mm. The Second Coat Shall Be Reinforced With Glass Fabric Between The First And Second Coat.6. The Treatment Shall Be Protected By Application Of Polymer Modified Cement Mortar Of Thickness 10Mm Applied At The Rate Of 50G Per Mm.7. Tech Specification : Tensile Adhesion Strength 0.5N/Sqmm (As Bonding Slurry). 26 Material And Labour For Aerated Autoclaved Concrete (Aac) Blocks Work According To Indian Standard Specification Is:2185(Part-3)-1984 And Latest Revision Built In Cement And Sand Mortar 1:6 With Aerated Autoclaved Concrete (Aac) Blocks Straight Or Curver On Plan Exceeding 6Mtr Mean Radius As In Sunken Floor Complete All As Specified And And As Directed By Engineer-In-Charge. 27 Supply Only Integral Water Proofing Compound. 28 Removing Excavated Material As In All Kind Of Soils Not Exceeding 50M And Depositing Where Directed At A Level Not Exceeding 1.5M Above The Starting Point Complete All As Specified And As Directed By Engineer-In- Charge. 29 Returning Filling In Any Type Of Soil, Including Spreading, Levelling,Watering And Well Ramming In Layer Not Exceeding 25 Cm In Each Layer, Complete All As Specified And As Directed By Engineer-In- Charge. 30 Material And Labour For Sand Filling Under Floor Or In Foundation Including Spreading Levelling, Watering And Well Ramming In Layers Not Exc 25 Cmetc Complete All As Specified And As Directed By Engineer-In- Charge. Note: Sand Shall Be Approved By Ge. 31 Material And Labour For Hard Core Using Broken Stone Aggregate Of Gauge Not Exc. 63Mm, Deposited Spread And Leveled In Layers Not Exc. 150 Mm Thick, Watered And Rammed To A True Surface Complete All As Specified And As Directed By Engineer-In- Charge. 32 Material And Labour For 75 Mm Thick Cement Concrete 1:4:8 , Type D-2 Using 40 Mm Graded Stone Aggregate As In Sub Base Of Floor. Finished Even And Smooth Without Using Extra Cement Complete All As Specified And As Directed By Engineer-In-Charge. 33 Material And Labour For Rendering 10 Mm Thick In Cement Mortar 1:6 On Fair Faces Of Brick Work Or Concrete Surfaces Of Walls And Finishing The Surface Even & Fair Faces Without Using Extra Cement Complete All As Specified And As Directed By Engineer-In- Charge. 34 Material And Labour For Rendering 5 Mm Thick In Cement Mortar In (1:3) On Ceiling And Finishing The Surface Even & Smooth Without Using Extra Cement Complete All As Specified And Directed. 35 Material And Labour For 15Mm Thick Rendering In Cement Mortar 1:4 On Fair Faces Of Brick Work Or Concrete Surfaces Even And Smooth Without Using Extra Cement Complete All As Specified And As Directed By Engineer-In-Charge. 36 Material And Labour For 15Mm Thick Rendering In Cement Mortar 1:4 On Fair Faces Of Brick Work Or Concrete Surfaces And Finishing Fair & Even Mixed With Liquid Water Proofing Compound As Per ManufacturerS Instructions But Without Using Extra Cement Complete All As Specified And As Directed By Engineer-In-Charge. Note :- Liquid Water Proofing Compound Shall Be Measured And Paid Separately. 37 Supply And Fixing Chicken Wire Mesh ( Murga Jali ) In Cement Plaster Or Over Joints Of R.C.C And Brickwork Or As Per Site Requirement Of 24 Gauge & 12 Mm Mesh And 300 Mm Width For Construction Joints And Chasing In Brick Work For Electrical Conduits Or Water Supply Pipes And Pegs/Nails With Nailing Machine As Required Before Rendering / Plastering Etc. Complete As Per Site Requirement Complete All As Specified And As Directed By Engineer-In- Charge.Note: Rendering / Plastering Shall Be Measured And Paid Seperately Under Serial Item No. 5.00 Of ScheduleA Boq Here-In- Before. Nothing Shall Be Paid Extra On Account Of Rendering / Plastering In This Item. 38 Material And Labour For Applying Acrylic Wall Care Putty On Internal Surfaces And External Surfaces Of Walls/Ceilings/Soffits (Thickness Vary From 1.5 To 2.5 Mm As Required For Desired Smoothness And Leveling Of Surfaces In Two Or More Layers) By Using Ready Made Acrylic Wall Care Putty Including Sand Papering After Filling The Putty To Make Surface Smooth And Ready For Receiving Painting Etc Complete All As Specified And Directed By Engineer-In- Charge.Make Of Acrylic Wall Care Putty : As Descriped In List Of Makes/Manufacturers Under Appendix B Here-In-After.Notes : (I) The Prepared Surface After Wall Putty, The Contractor Will Inform To The Ge As Well As To The Engineer-In-Charge For Site Inspection Before Applying Further Finishes. Please Note That The Further Finishes Work Will Start Only After Approval Of The Prepared Surface From The Ge As Well As To The Engineer-In-Charge Through Site Order. (Ii)The Make Of Acrylic Wall Care Putty Shall Be As Per The Recommendation Of Manufacturer Of Paint. 39 Material And Labour For Preparation Of New Surfaces And Applying 02 Coats Of Interior Acrylic Emulsion Paint (Light Shade As Approved By Ge ) @ 10.00 Sq.M/ Litre / 2.00 Coats By Using Roller/Brush To Wall Surfaces Over With And Including One Coat Of Interior Acrylic Emulsion Primer @ 10.00 Sq.M / Litre / 1.00 Coat As Recommended For Under Coat By Manufacturer Of Interior Acrylic Emulsion By Using The Brands Of Interior Acrylic Emulsion Paint And Interior Acrylic Emulsion Primer As Descriped In List Of Makes/Manufacturers Under Appendix B Here-In-After Complete All As Specified And Directed By Engineer-In- Charge. 40 Material And Labour For Complete Removal Of Existing Treatment Of Any Type / Description From Wall / Rcc Surfaces / Ceiling / Chajjas / Roof Projections Etc With Mechanical Means / Grinder And Applying 01 Coat Of Exterior Emulsion Paint (Light Shade) With Highlighter Of Any Existing Shade @ 10 Sqm/Litre/1 Coat By Using Roller To External Walls / Rcc Surfaces/Soffits Of Chajjas / Roof Projections /Cantilevers/ Balcony Etc Surfaces Over Acrylic Thick Wall Care Putty On External Surfaces Of Walls / Ceiling / Soffits ( Thickness Vary From 1.5 To 2.5Mm As Required For Desired Smoothness And Levelling Of Surfaces In Two Or More Layers) By Using Ready Made Wall Care Putty Including Sand Papering After Filling The Putty To Make Surface Smooth And Ready For Receiving Painting Etc, Over Including A Coat Of Exterior Wall Primer @ 10 Sqm/Litre/1 Coat As Recommended For Under Coat By Manufacturer Of Exterior Emulsion By Using Following Brands Of Emulsion And Primer Including Removing The Vegetation Of Any Type And Description The Making The Surface Good Complete All As Specified And Directed. 41 Material And Labour For Preparation Of Old Surfaces And Applying 02 Coats Of Interior Acrylic Emulsion Paint (Light Shade As Approved By Ge ) @ 10.00 Sq.M/ Litre / 2.00 Coats By Using Roller/Brush To Wall Surfaces Over With And Including One Coat Of Interior Acrylic Emulsion Primer @ 10.00 Sq.M / Litre / 1.00 Coat As Recommended For Under Coat By Manufacturer Of Interior Acrylic Emulsion By Using The Brands Of Interior Acrylic Emulsion Paint And Interior Acrylic Emulsion Primer As Descriped In List Of Makes/Manufacturers Under Appendix B Here-In-After Complete All As Specified And Directed By Engineer-In- Charge. 42 M&L For Preparing Existing Treated Surfaces Of Ceiling Including Cornices And Applying Two Coats Of White Wash By Making The Lime Slaked At Site And Shall Be Mixed And Stirred With About Five Liters Of Water For 1 Kg Of Unslaked Lime To Make A Thin Cream. This Shall Be Allowed To Stand For A Period Of 24 Hours And Shall Then Be Screened Through Clean Coarse Cloth. 1 Kg Of Gum Dissolved In Hot Water Shall Be Added To Every One Cubic Meter Of Lime Cream. About 1.3 Kg Of Sodium Chloride Dissolved In Hot Water Shall Also Be Added For Every 10 Kg Of Lime For Making The Coating Hard And Rub-Resistant. Small Quantity Of Ultramarine Blue (Upto 3 Gm Per Kg Of Lime) Shall Also Be Added To The White Wash Solution And The Whole Solution Shall Be Stirred Thoroughly Before Use Complete All As Specified And As Directed By Engineer-In-Charge. 43 Material And Labour For Preparation Of New Surfaces And Applying 02 Coats Of Exterior Acrylic Emulsion Paint ( Shade As Approved By Ge) With Highlighter Of Any Approved Shade, @ 5.00 Sq.M / Litre / 2.00 Coats By Using Roller To External Walls / Rcc Surfaces / Soffits Of Chajjas / Roof Projections / Cantilevers / Balcony Etc. Surfaces Over With And Including One Coat Of Exterior Acrylic Emulsion Primer @ 11.00 Sq.M / Litre / 1.00 Coat As Recommended For Under Coat By Manufacturer Of Exterior Acrylic Emulsion By Using The Brands Of Exterior Acrylic Emulsion Paint And Exterior Acrylic Emulsion Primer As Descriped In List Of Makes/Manufacturers Under Appendix B Here-In-After Complete All As Specified And Directed By Engineer-In- Charge. 44 Material & Labour For Applying Two Or More Coats Of 100% Premium Acrylic Emulsion Paint Having Voc Less Than 50 Gm/Litre And Uv Resistance As Per Is 15489:2004, Alkali & Fungal Resistance, Dirt Resistance Interior Paint Of Required Shade (Company Depot Tinted) With Silicon Additives @ 1.43 Litre/ 10 Sqm Over And Including Priming Coat Of Exterior Primer Applied @ 0.90 Litre/ 10 Sqm Including A Coat Of Exterior Wall Primer @ 11 Sq.M/Litre/1 Coat As Recommended For Under Coat By Manufacturer Of Exterior Emulsion By Using Following Brands Of Emulsion And Primer Complete All As Specified And Directed. 45 Material And Labour For Preparation Of Old Surfaces And Applying 02 Coats Of Exterior Acrylic Emulsion Paint ( Shade As Approved By Ge) With Highlighter Of Any Approved Shade, @ 5.00 Sq.M / Litre / 2.00 Coats By Using Roller To External Walls / Rcc Surfaces / Soffits Of Chajjas / Roof Projections / Cantilevers / Balcony Etc. Surfaces Over With And Including One Coat Of Exterior Acrylic Emulsion Primer @ 11.00 Sq.M / Litre / 1.00 Coat As Recommended For Under Coat By Manufacturer Of Exterior Acrylic Emulsion By Using The Brands Of Exterior Acrylic Emulsion Paint And Exterior Acrylic Emulsion Primer As Descriped In List Of Makes/Manufacturers Under Appendix B Here-In-After Complete All As Specified And Directed By Engineer-In- Charge. 46 Material And Labour For Complete Removal Of Existing Treatment Of Any Type / Description From Wall / Rcc Surfaces / Ceiling / Chajjas / Roof Projections Etc With Mechanical Means / Grinder And Applying One Coat Of Exterior Emulsion Paint (Light Shade) With Highlighter Of Any Approved Shade @ 5 Sqm/Litre/2 Coats By Using Roller To External Walls / Rcc Surfaces/Soffits Of Chajjas / Roof Projections /Cantilevers/ Balcony Etc Surfaces Over & Including A Coat Of Exterior Wall Primer @ 11 Sqm/Litre/1 Coat Over Acrylic Thick Wall Care Putty On External Surfaces Of Walls / Ceiling / Soffits (Thickness Vary From 1.5 To 2.5Mm As Required For Desired Smoothness And Levelling Of Surfaces In Two Or More Layers) By Using Ready Made Wall Care Putty Including Sand Papering After Filling The Putty To Make Surface Smooth And Ready For Receiving Painting Etc As Recommended For Under Coat By Manufacturer Of Exterior Emulsion By Using Following Brands Of Emulsion And Primer Complete All As Specified And Directed.Note For Item No 5 To 8 :- (A) The Prepared Surface After Wall Putty, The Contractor Will Inform To The Ge As Well As To The Engineer-In-Charge For Site Inspection Before Applying Further Finishes. Please Note That The Further Finishes Work Will Start Only After Approval Of The Prepared Surface From The Ge As Well As To The Engineer-In-Charge Through Site Order. 47 Material And Labour For For Preparing New Plastered Surfaces Of Ceilings And Applying Three Coats Of White Wash By Making The Lime Slaked At Site And Shall Be Mixed And Stirred With About Five Liters Of Water For 1 Kg Of Unslaked Lime To Make A Thin Cream. This Shall Be Allowed To Stand For A Period Of 24 Hours And Shall Then Be Screened Through Clean Coarse Cloth. 1 Kg Of Gum Dissolved In Hot Water Shall Be Added To Every One Cubic Meter Of Lime Cream. About 1.3 Kg Of Sodium Chloride Dissolved In Hot Water Shall Also Be Added For Every 10 Kg Of Lime For Making The Coating Hard And Rub-Resistant. Small Quantity Of Ultramarine Blue (Upto 3 Gm Per Kg Of Lime) Shall Also Be Added To The Last Two Coats Of White Wash Solution And The Whole Solution Shall Be Stirred Thoroughly Before Use Complete All As Specified And Directed By Engineer-In- Charge. 48 Material And Labour For Applying Three Coats Of White Wash On Newly Plastered Or Unplastered Ceiling Surfaces Including Preparation Of Surfaces, Complete All As Specified And Directed 49 Taking Down Chowkats Or Frames With Shutters (Without Taking Off Shutters From The Frames) Area Not Exc 1.5 Sqm Each As Doors, Windows And Ventilators And Removal From Site Complete All As Specified And Directed. 50 Taking Down Chowkats Or Frames With Shutters (Without Taking Off Shutters From The Frame) Exc 1.5 Sqm But Not Exc 4 Sqm Each Each As Doors, Windows And Ventilators And Removal From Site Complete All As Specified And Directed. 51 Supply & Fixing Factory Made Single Extruded Wpc ( Wood Polymer Composite ) Solid Door Frame / Chowkhat Of Size 45Mm X 70 Mm Comprising Of Virgin Polymer Of K Value 58-60 (Suspension Grade ), Calcium Carbonate And Nautral Fibers ( Wood Powder / Rice Husk / Wheat Husk ) And Non Toxic Additives (Maximum Toxcity Index Of 12 For 100 Gms ) Fabricated With Miter Joints After Applying Pvc Solvant Cement And Screwed With Full Body Threaded Star Headed Ss Screws Having Minimum Frame Density Of 750 Kg /Cum And Screw Withdrawl Strength Of 2200 N (Face ) & 1100 N (Edge) Minimum Compressive Strength Of 58 N /Sqmm Modulus Of Elasticity 900 N/Sqmm And Resisitence To Spread Of Flame Of Class A Category With Property Of Being Termite / Borer Proof , Water Moisture Proof And Fire Retaident And Fixed In Position With And Including Ms Hold Fast Lugs / Ss Dash Fastner Of Required Dia And Length With And Including Supply And Fixing (03 Nos Per Frame ) 100 Mm Long Ss Butt Hinges Complete All As Specified And As Directed By Engineer-In- Charge. 52 Supply & Fixing Factory Made Single Extruded Wpc ( Wood Polymer Composite ) Solid Door Frame / Chowkhat With Double Rebate Of Size 65Mm X 125 Mm Comprising Of Virgin Polymer Of K Value 58-60 (Suspension Grade ), Calcium Carbonate And Nautral Fibers ( Wood Powder / Rice Husk / Wheat Husk ) And Non Toxic Additives (Maximum Toxcity Index Of 12 For 100 Gms ) Fabricated With Miter Joints After Applying Pvc Solvant Cement And Screwed With Full Body Threaded Star Headed Ss Screws Having Minimum Frame Density Of 750 Kg /Cum And Screw Withdrawl Strength Of 2200 N (Face ) & 1100 N (Edge) Minimum Compressive Strength Of 58 N /Sqmm Modulus Of Elasticity 900 N/Sqmm And Resisitence To Spread Of Flame Of Class A Category With Property Of Being Termite / Borer Proof , Water Moisture Proof And Fire Retaident And Fixed In Position With And Including Ms Hold Fast Lugs / Ss Dash Fastner Of Required Dia And Length With And Including Supply And Fixing (03 Nos Per Frame ) 100 Mm Long Ss Butt Hinges Complete All As Specified And As Directed By Engineer-In- Charge. 53 Supply & Fixing Factory Made Single Extruded Wpc ( Wood Polymer Composite ) Solid Plain Flush Door Shutter Of 30 Mm Thick , Size Comprising Of Virgin Polymer Of K Value 58-60 (Suspension Grade ), Calcium Carbonate And Nautral Fibers ( Wood Powder / Rice Husk / Wheat Husk ) And Non Toxic Additives (Maximum Toxcity Index Of 12 For 100 Gms ) Having Minimum Density Of 650 Kg /Cum And Screw Withdrawl Strength Of 1800 N (Face ) & 900 N (Edge) Minimum Compressive Strength Of 50 N /Sqmm Modulus Of Elasticity 850N/Sqmm And Resisitence To Spread Of Flame Of Class A Category With Property Of Being Termite / Borer Proof , Water Moisture Proof And Fire Retardant And With And Including Supply & Fixing Of 02 Nos (Per Leaf) Ss 150Mm Long Tower Bolt, Supply & Fixing Of 02 Nos (Per Door) Ss 300Mm Long Sliding Bolt With And Including Supply & Fixing Of 02 Nos (Per Leaf) Stainless Steel 150Mm Long Handle Complete All Specified And Directed By Engineer -In-Charge. 54 Supply & Fixing Factory Made Single Extruded Wpc ( Wood Polymer Composite ) Solid Decorative Flush Door Shutter Of 30 Mm Thick , Size Comprising Of Virgin Polymer Of K Value 58-60 (Suspension Grade ), Calcium Carbonate And Nautral Fibers ( Wood Powder / Rice Husk / Wheat Husk ) And Non Toxic Additives (Maximum Toxcity Index Of 12 For 100 Gms ) Having Minimum Density Of 650 Kg /Cum And Screw Withdrawl Strength Of 1800 N (Face ) & 900 N (Edge) Minimum Compressive Strength Of 50 N /Sqmm Modulus Of Elasticity 850N/Sqmm And Resisitence To Spread Of Flame Of Class A Category With Property Of Being Termite / Borer Proof , Water Moisture Proof And Fire Retardant And With And Including Supply & Fixing Of 02 Nos (Per Leaf) Ss 150Mm Long Tower Bolt, Supply & Fixing Of 02 Nos (Per Door) Ss 300Mm Long Sliding Bolt With And Including Supply & Fixing Of 02 Nos (Per Leaf) Stainless Steel 150Mm Long Handle Complete All Specified And Directed By Engineer -In-Charge. 55 Supply & Fixing Factory Made 30Mm Thick Solid Wpc ( Wood Polymer Composite ) Wiremesh Door Shutter Of Required Size Comprising Of Virgin Pvc Resin Of K Value 57-60 ( Suspension Rade ), Calcium Carbonate And Natural Fibers ( Wood Powders/ Rice Husk/ Wheat Husk ) And Non Toxic Additives, Made From Extrusion Process Wpc Foam Sheet Single Extruded ( Inner ) With Having Minimum Density Not Less Than 650 Kg/Cum , Having Good Screw Holding Capacity ( Screw Withdrawal Strength Of 2000 N ( Face ) & 1100 N ( Edge ), Minimum Compressive Of 50 N/Mm2, Modulus Of Elasticity 850N/Mm2 And Resistance Of Spread Of Flame Of Class A Category With Property Of Being Termite/ Borer Free.Water/ Moisture Proof And Fire Retardant. Pvc Foil Of Minimum 14 Microns Thick Of Approved Design Pasted On Both Faces Of Shutter For Fixing Mosquito Mesh And Xtn Aluminium Mesh Together On Panel Area Of Door Except Stiles And Rails To Be Panelled With And Including Mesh With Self Tapping Round Headed Scresws At Required Distance, Screws And Edges Covered With Feathered Pvc Edge Beading All Around Of Mesh And Fixing Stainless Steel Butt Hinges Of Required Size With Necessary Full Body Threaded Star Headed Counter Sunk Ss Screws With And Including 03 Nos Door Stainless Steel Butt Hings 100Mm Long With Stainlessd Steel Screws For Each , 02 Nos Stainless Steel Barrel Tower Bolts Of Extrude Section, 150Mm Long (Isi Marked), 2 Nos Stainles Steel Handles, 125 Mm Long, (Isi Marked) , 01 No. Of Helical Door Spring Of 300 Mm Length Complete All As Specified And As Directed By Engineer-In-Charge. Note: 1. Material Test Certificate Of All The Items And Authentication Should Be Compulsory Provided By The Manufacturing Company 2. The Rate Of 03 Nos Door Stainless Steel Butt Hings 100Mm Long With Stainlessd Steel Screws For Each , 02 Nos Stainless Steel Barrel Tower Bolts Of Extrude Section, 150Mm Long (Isi Marked), 2 Nos Stainles Steel Handles, 125 Mm Long, (Isi Marked) , 01No. Of Helical Door Spring Of 300 Mm Length Is Inclusive In This Item And Nothing Shall Be Paid Extra On This Item..3. The Rate Of Mosquito Mesh And Xtn Aluminium Mesh Is Included In This Item And Nothing Shall Be Paid Extra On This Account. 56 Supply And Fixing Factory Made Upvc White Colour Casement (Openable) Window (Area Exceeding 1.00 Sqm But Not Exceeding 2.00 Sqm Each) Made Of Extruded Profiles With Wall Thickness Of 2.3Mm ( + – 0.2Mm). Window Profile With Hollow Section With Multi Chamber, Frame (60Mm X 58Mm), Sash (60Mm X 73Mm), T Profile (One Vertical Length In Between Two Shutters) (60Mm X 74Mm), Glazing Bead (35Mm X 20Mm) Will Be Mitered Cut And Fusion Welded At All Corners, Including Drilling Of Holes For Fixing Hardware And Drainage Of Water Etc., Making Arrangement For Fixing Of Hardware. Epdm Gasket 1.2 +– 0.2Mm Thick, Galvanized Steel Frame (28Mm X 21.5Mm), Sash (31Mm X 27.5Mm). T Profile (27Mm X 17Mm) To Be Inserted In Required Profile, Frame Will Be Fixed To The Wall With 8 Mm X 100Mm Long Fasteners. Hardware: [Casement Handle Made Of Zinc Alloyed (White Powder Coated), But Hinges OfZinc Alloyed (White Powder Coated), Transmission Gear Made Of Mild Steel With Multi Point Locking System] And 5Mm Thick Glazing With Selected Quality Glass.(Note: The Unit Rate Quoted By Contractor Excludes Cost Of Glass And Includes All Other Connected Accessories. Net Opening Will Be Measured For Payment Purpose.) 57 Material And Labour For 75 Mm Thick Pcc 1:3:6 , Type C-1 Using 20 Mm Graded Stone Aggregate As In Plinth Protection, Finishing The Surface Even And Smooth Without Using Extra Cement Complete All As Specified And As Directed By Engineer-In- Charge. 58 Material And Labour For 75 Mm Thick Pcc 1:3:6 , Type C-2 Using 40 Mm Graded Stone Aggregate As In Plinth Protection, Finishing The Surface Even And Smooth Without Using Extra Cement Complete All As Specified And As Directed By Engineer-In- Charge. 59 Demolition And Breaking Up Drain Pipes (Salt Glazed Ware, Ac Or Reinforced Concrete)Of Any Dia Set In Cement Laid In Trenches Incl All Fittings & Accessorises Complete All As Specified And As Directed By Engineer-In- Charge. 60 Supply & Fixing For 4 Mm Thick, Sheet Glass Ordinary Quality And Glazing With Oil Putty In Square Not Exceeding 0.5 Sqm In Each Pane Complete All As Specified And As Directed By Engineer-In- Charge. 61 Supply & Fixing 4.0 Mm Thick Figured Glass Pin Head Type And Glazing With Oil Putty In Square N.Exc 0.5 Sqm In Each Pane Complete All As Specified And Directed 62 Supply & Fixing 5.5 Mm Thick, Sheet Glass Ordinary Quality Not Exceeding 0.50 Sqm In Each Pane Complete All As Specified And As Directed By Engineer-In- Charge. 63 Supply & Fixing 5.5 Mm Thick, Sheet Glass Ordinary Quality Exceeding 0.50 Sqm In Each Pane Complete All As Specified And As Directed By Engineer-In- Charge. 64 Material And Labour For Providing And Fixing Aluminium Work With Polyester Powder Coated Aluminium ( Minimum Thickness Of Polyester Powder Coating 50 Micron For Doors, Windows, Ventilators And Partitions With Extruded Built Up Standard Tubular Sections/Appropriate Z Sections And Other Sections Of Approved Make Conformikng To Is:733 And Is :1285, Fixing With Dash Fasteners Of Required Dia And Size,Including Necessary Filling Up The Gaps At Junctions I.E At Top , Bottom And Sides With Required Epdm Rubber / Neoprene Gasket Etc. Aluminium Sections Shall Be Smooth , Rust Free, Straight, Mitred And Jointed Mechanically Wherever Required Including Aluminium Cleat Angle, Aluminium Snap Beading For Glazing/ Paneling , C.P. Brass/ Stainless Steel Screws, All Complete All As Specified And Directed By Engineer-In-Charge .Note :- (I) Weight Of Aluminium Sections , Aluminium Cleat Angles , Aluminium Butt Hinges, Aluminium Handles , Aluminium Tower Bolts , Aluminium Peg Stays & Aluminium Snap Beading Shall Be Physically Ascertained Through A Board Of Officers Convened By Ge And Payment Shall Be Made Only After Ascertaining The Actual Weight Of Aluminium At Site.(Ii) The Rate Of Material And Labour For Providing The Epdm Rubber, Neoprene Gasket , C.P. Brass / Stainless Steel Screws Are Included In This Item And Nothing Shall Be Paid Extra On This Account. (Iii) During Considering The Weight Of Aluminium Sections , Aluminium Cleat Angles , Aluminium Butt Hinges, Aluminium Handles , Aluminium Tower Bolts , Aluminium Peg Stays & Aluminium Snap Beading , The Weight Of Epdm Rubber, Neoprene Gasket , C.P. Brass/ Stainless Steel Screws Shall Not Be Considered For Measurments And Payments. Only The Weight Of The Aluminium Sections , Aluminium Cleat Angles, Aluminium Butt Hinges, Aluminium Handles , Aluminium Tower Bolts , Aluminium Peg Stays & Aluminium Snap Beading Shall Be Considered And Measurment And Payment Shall Be Made Accourdingly.(Iv) During The Weight Of Aluminium Sections , Aluminium Cleat Angles , Aluminium Butt Hinges, Aluminium Handles , Aluminium Tower Bolts , Aluminium Peg Stays & Aluminium Snap Beading ,The Weight Of Polyester Powder Coating 50 Micron Shall Not Be Considered For Weight But The Rate Of Material And Labour For Providing Polyester Powder Coating 50 Micron Is Included In This Item And Nothing Shall Be Paid Extra On This Account. (V) Glazing /Paneling And Wire Mesh Shall Be Measured And Paid Seperately. (V)The Board Shall Be Duly Countersigned By Ge Shall Enclosed With Final Bill . 65 Supply & Fixing Stainless Steel Wire Cloth 0.36 Mm Nominal Dia Of Wire And Average Width Of Aperture 1.4Mm And Fixed With Tinned Tacks To Stainless Steel Wire Staple Complete All As Specified And As Directed By Engineer-In-Charge. 66 Supply & Fixing Galvanised Ms Wire Cloth 0.36 Mm Nominal Dia Of Wire And Average Width Of Aperture 1.4Mm And Fixed With Tinned Tacks To Galvanised Ms Wire Staple Complete All As Specified And As Directed By Engineer-In-Charge. 67 Material And Labour For Providing And Laying Premium (1St Quality) Straight Edge,Stain Free, Glooss Finish, Square Marbonite Double Charged Vitrified Tiles Size In 600Mm X 600Mm X 9Mm To 10Mm Thick As In Floors Etc. Shade As Approved By Ge , Set And Jointed With Using Spacer And Approved High Polymer Modified, Grey Cement-Based Tile Adhesive Suitable For Fixing Medium Format Tile/Stone In Walls/Floor Conforms To Is 15477 : 2019 Type 2T “Adhesives For Use With Ceramic, Mosaic And Stone Tiles” Conforms To En 12004: 2017 And Is A Normal Cementitious Adhesives (C1) With Slip Resistance (T) Of Class C1 And Necessary Grouting As Per Manufacturer’S Instruction, Completed All As Specified And Directed By Engineer-In-Charge. 68 Supply And Fixing Anodised Aluminium Snap Grid Frame Work For False Ceiling 605Mm X 605 Mm Etc Complete All As Specified And As Directed By Engineer-In-Charge. 69 Supply And Fixing False Ceiling At All Heights With Grg (Glass Fibre With Reinforced Gypsum) False Ceiling Tiles Of Size 595 X 595 Mm Of Approved Tecture Design And Patterns Having Moisture Content Less Than 2% Humidity Resistance Of 99%, Nrc 0.50 To 0.75 As Per Is 8225:1987, Noncombustible As Per Bs 476 (Part 4)- 1970 And Light Reflectance Of 85%D (Minimum) To Be Laid In True Horizontal Level Suspended On Inter Locking Metal T-Grid Of Hot Dipped Galvanisezed Iron Section Of 0.33Mm Thick (Galvanized @ 120 Grams Per Sqm Including Both Sides) Comprising Of Main T Runners Of Size 15 X 32 Mm Of Length 3000 Mm, Cross-T Of Size 15 X 32Mm Of Length 1200Mm And Secondary Intermediate Cross T Of Size 15 X 32 Mm Of Length 600Mm To Form Grid Module Of Size 600 X 600Mm, Suspended From Ceiling Using Galvanised Mild Steel Items (Galvanizing @ 80 Grams Per Sqm) I.E 50 Mm Long, 8 Mm Outer Diameter M-6 Dash Fasteners, 6Mm Dia Fully Threaded Hanger Rod Upto 1000 Mm Length And L Shape Level Adjuster Of Size 85 X 25 X 2Mm. Galvanized Iron Perimeter Wall Angle Of Size 24 X 24 X 0.40Mm Of Length 3000 Mm To Be Fixed On Periphery Wall I Partition With Help Of Plastic Rawl Plugs At 450 Tiles Fully Center To Center And 40Mm Long Dry Wall Wodd Screws. The Work Shall Be Carried Out As Per Specifications, Drawing And As Per Directions Of The Engineer-In-Charge. 70 Material And Labour Anodised Aluminium Frame For Doors, Windows, Ventilators With One Or More Rebates Including Joining Cleat For Fixing Etc. Omplete All As Specified And As Directed By Engineer-In-Charge. 71 Material And Labour For Providing And Fixing Aluminium Work With Polyester Powder Coated Aluminium ( Minimum Thickness Of Polyester Powder Coating 50 Micron For Doors, Windows, Ventilators And Partitions With Extruded Built Up Standard Tubular Sections/Appropriate Z Sections And Other Sections Of Approved Make Conformikng To Is:733 And Is :1285, Fixing With Dash Fasteners Of Required Dia And Size,Including Necessary Filling Up The Gaps At Junctions I.E At Top , Bottom And Sides With Required Epdm Rubber / Neoprene Gasket Etc. Aluminium Sections Shall Be Smooth , Rust Free, Straight, Mitred And Jointed Mechanically Wherever Required Including Aluminium Cleat Angle, Aluminium Snap Beading For Glazing/ Paneling , C.P. Brass/ Stainless Steel Screws, All Complete All As Specified And Directed By Engineer-In-Charge .Note :- (I) Weight Of Aluminium Sections , Aluminium Cleat Angles & Aluminium Snap Beading Shall Be Physically Ascertained Through A Board Of Officers Convened By Ge And Payment Shall Be Made Only After Ascertaining The Actual Weight Of Aluminium At Site.(Ii) The Rate Of Material And Labour For Providing The Epdm Rubber, Neoprene Gasket , C.P. Brass / Stainless Steel Screws Are Included In This Item And Nothing Shall Be Paid Extra On This Account. (Iii) During Considering The Weight Of Aluminium Sections , Aluminium Cleat Angles & Aluminium Snap Beading , The Weight Of Epdm Rubber, Neoprene Gasket , C.P. Brass/ Stainless Steel Screws Shall Not Be Considered For Measurments And Payments. Only The Weight Of The Aluminium Sections , Aluminium Cleat Angles & Aluminium Snap Beading Shall Be Considered And Measurment And Payment Shall Be Made Accordingly.(Iv) During The Weight Of Aluminium Sections , Aluminium Cleat Angles & Aluminium Snap Beading ,The Weight Of Polyester Powder Coating 50 Micron Shall Not Be Considered For Weight But The Rate Of Material And Labour For Providing Polyester Powder Coating 50 Micron Is Included In This Item And Nothing Shall Be Paid Extra On This Account. (V) Powder Coated Butt Hinges, Aluminium Handles, Aluminium Tower Bolts & Aluminium Peg Stays Shall Be Measured And Paid Seperately Under Respective Itmes Of ScheduleA Boq.(V) Glazing /Paneling And Wire Mesh Shall Be Measured And Paid Seperately. (Vi)The Board Shall Be Duly Countersigned By Ge Shall Enclosed With Final Bill 72 Material And Labour Anodised Aluminium Grill (Anodised Transparent Of Dyed To Required Shade According To Is: 1868 With Minimum Anodic Coating Of Grade Ac 15) Of Approved Design/Pattern, With Approved Standard Section And Fixed To The Existing Window Frame With C.P. Brass/Stainless Steel Screws @ 200 Mm Centre To Centre, Including Cutting The Grill To Proper Opening Size For Fixing And Operation Of Handles And Fixing Approved Anodised Aluminium Standard Section Around The Opening, All Complete As Per Requirement And Direction Of Engineer-In-Charge. 73 Taking Up Or Down Galvanised Steel Water Tubing (Gi Pipe) 15Mm Bore Including Fitting/Connection From Wall/Ceiling/Floor/Concealed Etc. Complete All As Specified And As Directed By Engineer-In-Charge. 74 Taking Up Or Down Galvanised Steel Water Tubing (Gi Pipe) 20Mm Bore Including Fitting/Connection From Wall/Ceiling/Floor/Concealed Etc. Complete All As Specified And As Directed By Engineer-In-Charge. 75 Supply And Fixing 16 Mm Bore Cpvc Pipe Sdr 11 With And Including Cpvc Sdr 11 Fittings And Fixed To Walls & Ceilings Or Laid In Floors, Complete Complete All As Specified And As Directed By Engineer-In-Charge 76 Supply And Fixing 20 Mm Bore Cpvc Pipe Sdr 11And Plain Cpvc Sdr 11 Fitting With All Fitting And Fixed To Walls & Ceilings Or Laid In Floors, Including Taking Down Unservicable Existing Gi Tubing Of 20Mm Bore And Fittings Complete Complete All As Specified And As Directed By Engineer-In-Charge. 77 Supply And Fixing 25 Mm Bore Cpvc Pipe Sdr 11And Plain Cpvc Sdr 11 Fitting With All Fitting And Fixed To Walls & Ceilings Or Laid In Floors, Including Taking Down Unservicable Existing Gi Tubing Of 20Mm Bore And Fittings Complete Complete All As Specified And As Directed By Engineer-In-Charge. 78 Material And Labour For Cutting Chases In Brick Wall , Pinning In. Making Good To Facings Where Required And Pointing In Cement Mortar 1:3 Or Pcc 1:2:4 To Ends Or Edges Of Landings, Steps, Cills, Sunshades, Shelves, Lintels, Etc.; And Cutting Chases For Concealed Water Tubing Or Concealed Conduit Wiring, Etc., And Making Good, Cutting Exc 10 Cm But Not Exc 20 Cm Girth Complete All As Specified And As Directed By Engineer-In- Charge.. 79 Supply And Fixing In Repair Brass Chromium Plated Wall Mixer For Mixing Hot & Cold Water Screwed Down, Screwed For 15Mm Bore Pipe Or For Brass Ferrule Complete All As Specified And As Directed By Engineer-In-Charge. 80 Supply And Fixing In Repair Bib Taps Cost Copper Alloy With Crutch Or Butterfly Handle , Screwed Down , Chromium Plated Screwed For Iron Pipe Or Brass Ferrul For 15Mm Bore Dia Pipe Complete All As Specified And Director. 81 Supply And Fixing In Reapir 15Mm Bore Bib Tap, Long Body, Fancy Type, Chromium Plated, Cast Copper Alloy With Crutch Or Butterfly Handle, Screwed Down, Screwed For Iron Pipe Or For Brass Ferrule Complete All As Specified And As Directed By Engineer-In-Charge. 82 Supply And Fixing In Repair 15Mm Bore Stop Valves, Fancy Type, Chromium Plated With Long Shank And Cup (Concealed Type) Cast Copper Alloy, Screwed Down, High Pressure, With Crutch Or Butterfly Handle, Screwed Both Ends For Iron Pipe Or For Unions And Fixed For Iron Pipe Or For Brass Ferrule Complete All As Specified & Directed By Engineer-In-Charge. 83 Supply And Fixing In Repair Angular Stop Cock With Wall Flange, Fency Type Chromium Plated Cast Copper Alloy Screwed Down, High Pressure, Screwed One Ends For 15Mm Bore Of Iron Pipe Or For Union And Fixed In Position Complete All As Specified & Directed By Engineer-In-Charge. 84 Supply And Fixing In Repair Vitreous China Wash Hand Basin, White, Flat Back, Size 450Mm X 300 Mm Including Cast Iron Cantilever Bracket With And Including 32 Mm Dia Brass Waste Coupling And With And Including Fixing Of Waste Fitting And Union Complete All As Specified And As Directed By Engineer-In-Charge. 85 Supply And Fixing In Repair Ptmt Mirror Cabinet Of Size 380Mm X 450Mm Best Quality Confirming Ot Sample Kept In GeS Office Complete All As Specified And Directed By Engineer-In-Charge. 86 Supply And Fixing In Replacement Sink With Drainage Board Made Of Stainless Steel 1 Mm Thick Kitchen Or Laboratory With Plugs, Washers And Wastes; Including Bedding In Cement Mortar To Dwarf Wall Or Including Fixing Cantilever Brackets And Connecting Union To Pipe Overall Size 915Mm X460Mm Bowl Size 410Mm X330Mm X160Mm Complete All As Specified And As Directed By Engineer-In-Charge. 87 Supply & Fixing In Replacement Brass Cp Mixer For Mixing Hot & Cold Water Screwed Down For Iron Pipe And Fixed For Iron Pipe 15Mm Bore Complete All As Specified And As Directed By Engineer-In-Charge. 88 Supply And Fixing In Repair Stainless Steel Plate Rack Of Size 900Mm X 600Mm X 250Mm And Thickness Of Stainless Steel Strip Of 1Mm Fixed On Wall Etc. Complete All As Specified And Directed . 89 Material And Labour For Cutting Holes In Brick Walls Built In Cement Mortar (Not Exceeding Half Brick) For Inserting Hold Fast And Making Good Dismantled Portion In Cm 1:3 Or Cement Concrete 1 : 2 : 4 , Type B1 As Required , Depth Of Embedded Portion Exceeding Half Brick Walls And Not Exceeding One Brick Of Hold Fast Or Lugs Measured From The Face Of The Jamb Into Walls Complete All As Specified And As Directed By Engineer-In- Charge. 90 Material And Labour For In Repair Vitreous China Wash Down Water Closet Pan Wall Hanging Single Piece (With And Including Flushing Cistern Ewc) P Trap, With And Including White Coloured Closed Pattern Plastic Seat Cover, Hand Faucet , With And Including Mild Steel Chromium Plated Or Aluminised Hinging Device Complete All As Specified And As Directed By Engineer-In- Charge. 91 S & F In Repairs Cp Stainless Steel Grating (With Or Without Waste Hole), 125Mm Size, Fixed On Floor/Nahani Gully Trap Traps Etc Complete All As Specified And Directed. 92 S&F In Repair 25Mm Dia And 1Mm Thick Stainless Steel Drapery Rod Including With Bracket / Wall And Other Side Fancy Knobs At Both Ends As Approved By Engineer-In-Charge/Ge Including Taking Down Old Existing Rod/Pelmet With Accessories Complete All As Specified. 93 Supply And Fixing Cp Brass Fancy Type Corner Glass Shelf (25Cm/30Cm ) With Cp Brass Bracket & Railing Etc. Complete All As Specified And As Directed By Engineer-In- Charge. 94 Supply And Fixing In Repair Stainless Steel, Chromium Plated, Decorative Type, Soap Dish Holder Of Approximate Size 160Mm X 160Mm X 90 Mm Fixed To Wall With Rubber Plugs Complete All As Specified And As Directed By Engineer-In-Charge. 95 Supply & Fixing In Replacement Brass Chromium Plated Tubular Towel Rail 20Mm Dia D Type, 600Mm Long Between Flanges Fixed To Plug , Bracket With Chromium Plated Brass Screws Complete All As Specified And Directed By Engineer-In-Charge. 96 Supply And Fixing 110 Mm Bore Of Pipe Pvc (Swr) Type B Pipes Single Socket 6 Kg/Sq Cm In Any Length With Stack Clamps Made Out Of 50Mm By 5 Mm Flat Iron And 16Mm Dia Round Iron Stays, Including Bolts And Nuts And Securing Ends Of Stays To Wall At A Distance Of 100-120Mm Away From Walls Complete All As Specified And As Directed By Engineer-In- Charge. Including Taking Down Old Ac Eaves Gutters And Rainwater Pipes ( Of Any Size And Pattern), Including All Fittings, Compete All As Specified And As Directed By Engineer - In-Charge. 97 Supply & Fixing 110 Mm Bore Of Pipe Pvc (Swr) Type B Ring Fit Pipes Single Socket In Any Length With Stack Clamps As Shown In Btd Drg No. 916 Sheet 1/4 To 4/4 And Btd-917 Sheet Sheet 1/1 Of Stays To Wall At A Distance Of 100-120Mm Away From Walls Complete All As Specified And As Directed By Engineer-In- Charge Including Taking Down Old Ac Eaves Gutters And Rain Water Pipes ( Of Any Size And Pattern) Including All Fittings, Compete All As Specified And As Directed By Engineer - In-Charge. 98 Dismantling And Disconnecting Of Existing Ci Soil Vent Pipe 100 Mm Bore Fixed To Wall,Laid In Trenches Incl All Fittings & Accessories Complete All As Specified And Directed. 99 Dismantling And Disconnecting Of Existing Ci Soil Vent Pipe 75 Mm Bore Fixed To Wall,Laid In Trenches Incl All Fittings & Accessories Complete All As Specified And Directed. 100 Supply And Fixing 110 Mm Bore, Pvc (Swr) Fittings Type -B Such As Bends, Tee, Shoe Etc; Fixed To Pvc Pipes, Compete All As Specified And As Directed By Engineer - In-Charge. 101 Supply & Fixing 110Mm Bore Pvc (Swr) Pipes Single Socketed In Any Length With Rubber Ring Joints Laid In Trenches Or In Floors Complete All As Specified And As Directed By Engineer-In- Charge. 102 S&F 110 Mm Bore Of Pvc (Swr) Bends And Tee, Type - B Of Any Radius / Shoe With Access Door Fixed To Pvc Pipes Complete All As Specified And Directed. 103 S&F 75 Mm Bore Of Pipe Pvc (Swr) Pipes Type - B Single Socket In Any Length With Rubber Ring Joint Fixed To Walls With Ms Clamps Of F1 25X2Mm Complete All As Specified And Directe 104 S&F 75 Mm Bore Of Pipe Pvc (Swr) Pipes Type - B Double Socket In Any Length With Rubber Ring Joint Fixed To Walls With Ms Clamps Of F1 25X2Mm Complete All As Specified And Directe 105 S&F 75 Mm Bore Of Pvc (Swr) Bends & Tee, Type - B Of Any Radius / Shoe With Access Door Fixed To Pvc Pipes Complete All As Specified And Directed. 106 S&F In Repairs Pvc (Swr) Gully Trap Of Size 150 X 150 Mm, Square Or Round Mouthed, Type P Setting And Jointing With Solvent Cement Complete All As Specified And Directed. 107 Supply And Fixing In Repair Pvc (Swr) Type -B Floor Trap Any Type (Q, S, P), 110/75Mm Dia With Grating Including Jointing To Waste Pipe Fixed In Cement Concrete (1:2:4) Type B-1 Using 20Mm Graded Stone Aggregate Complete All As Specified And Directed By Engineer-In- Charge. 108 Supply And Fixing In Replacement 10 Litres Capacity Pvc Valveless Syphonic Action Type Low Level Flushing Cistern White With Inlet, Ball Valve, Float, Handle Including Brackets And 32Mm Dia Pvc Flush Pipe Complete All As Specified And Directed By Engineer-In-Charge. 109 S&F In Repair Vitreous China Wash Basin, White, Oval Type , Size 450 Mm X 300 Mm Fixed On And Including Cast Iron Cantilever Bracket, 32 Mm Dia Brass Waste Coupling And Including Fixing Of Tap, Waste Fitting And Union Complete All As Specified And Directed. 110 Supply & Fixing In Repair Chromium Plated Square Shower Rose 200Mm X 200Mm Size, With Or Without Swivel Joints, Any Size, Including Fixing To Steel Pipe Or Union For 15Mm Bore Of Pipe Complete All As Specified And As Directed By Engineer-In-Charge. 111 Supply & Fixing In Repair Pvc Connections 15Mm Size With Brass Nuts Of Length 450Mm Complete All As Specified And As Directed By Engineer-In-Charge. 112 Supply & Fixing In Repair Pvc Waste Pipe With Socket Suitable For Connection To Waste Fittings Of 32/40Mm Dia, And Of Length Minimum 75 Cm Complete All As Specified And As Directed By Engineer-In-Charge. 113 Supply And Fixing In Replacement Three Layers 500 Litre Hdpe Water Storage Tanks Polyproof. White In Colour Rotational Moulded Polyethylene (Cylindrical Vertical With Closed Top) Hoisted And Fixed In Position Including Supply And Fixing Of Suitable Size Inlet/Outlet Arrangement & Other Accessories Complete All As Specified And As Directed By Engineer-In-Charge. 114 Supply And Fixing In Replacement Three Layers 1000 Litre Hdpe Water Storage Tanks Polyproof. White In Colour Rotational Moulded Polyethylene (Cylindrical Vertical With Closed Top) Hoisted And Fixed In Position Including Supply And Fixing Of Suitable Size Inlet/Outlet Arrangement & Other Accessories Complete All As Specified And As Directed By Engineer-In-Charge. 115 Supply And Fixing In Repair Ball Valve High Pressure Of Ptmt With Epoxy Coated Aluminium Rod And High Density Plastic Ball Screwed For Iron Pipe Of Size 20 Mm Bore (Minimum Weight 20Mm-210 Gram) Complete All As Specified And As Directed By Engineer-In- Charge. 116 Supply & Fixing In Repair Gun Metal, Globe Or Gate Valve (Isi Marked), Brass Cast Copper Alloy, With Iron Wheel Head, Screwed Both Ends Suitable For 20Mm Bore Iron Pipes Complete All As Specified And As Directed By Engineer-In-Charge. 117 Supply & Fixing In Repair Gun Metal, Globe Or Gate Valve (Isi Marked), Brass Cast Copper Alloy, With Iron Wheel Head, Screwed Both Ends Suitable For 25Mm Bore Iron Pipes Complete All As Specified And As Directed By Engineer-In-Charge. 118 Supply And Fixing In Replacement Bevelled Edge Mirror Selected Quality 5Mm Thick Glass Mounted And Fixed To With Chromium Plated Brass Screws And Cup Washers, With And Including Pvc Frame Around Made Of Pvc Channel, Complete All As Specified And Directed By Engineer-In-Charge. 119 Supply And Fixing In Repairs Sheet Glass Shelf Assembly Consisting Of 5.5Mm Thick Sheet Glass Shelf 12Cm Wide With Chromium Plated Bracket Guard And Railing 60Cm Long Complete All As Specified And As Directed By Engineer-In- Charge. 120 Roughening Surfaces Of Old Concrete Floor By Picking, Sweeping Clean And Washing Down With Water To Remove Dust, Etc. Complete All As Specified And As Directed By Engineer-In-Charge. 121 Dismantling Floor, Hearth Or Wall Tiling Including Cement Mortar Bedding (But Not Backing), Removing Serviceable Tiles To Store And Rubbish Off The Permises Etc. Complete All As Specified And Directed By Engineer-In-Charge. 122 M&L For Pcc (1:2:4) Type B-1, Using 20 Mm Graded Stone Aggregate As In Floor Surface Finished Fair 30 Mm Thick Below Tiles Complete All As Specified And Directed. . 123 M & L Non-Skid Coloured Ceramic Tiles 7 To 8 Mm Thick (Square/ Rectangular) Area Of Each Tile Exceeding 0.11 Sqm But Not Exceeding 0.18 Sqm, In Floors Etc. Set And Jointed In Neat Cement Slurry And Pointed In White Or Coloured Cement To Match Over & Including 15Mm Thick Screed In Cm 1:6 Complete All As Specified And Directed. 124 Material And Labour 25Mm Thick Cement Concrete Type B-1, 1:2:4 (12.5 Mm Graded Stone Aggregate) As Floors, Sub-Floors Etc And Finishing Surfaces Of Concrete Topping As Even & Fair Or Even & Rough To Receive The Topping Layer Complete All As Specified And Directed By Engineer-In-Charge. 125 Material And Labour For Double Charge Vitrified Ceramic Tiles ,Stain Free, Having Size Not Less Than 600X300Mm And 8 Mm Thick, Premium (1St Quality) Straight Edge, Colour As Approved By Ge , As In Vertical Surfaces Such As Skirting , Set And Jointed In Neat Cement Slurry And Laid Over And Including 10 Mm Thick Rendering In Cement Mortar 1:4 Complete All As Specified And As Directed By Engineer-In- Charge. 126 Material And Labour Granite (Of Any Type) Work (Table Rubbed And Polished) As In Steps, Pillars,Win Dow-Cills, Cooking Platforms And Like In Laid Over And Including 15 Mm Thick Screed In Cement Mortar (1:4) And Pointing In White Cement (1:2) Using Marble Dust With Admixture Of Pigment To Match With Marble Shade And Roundening To The Edge Of Stone Slabs On Edges Etc. Complete All As Specified And As Directed By Engineer-In-Charge. 127 Dismantling Stone Slabs And Tiles Of Any Description Or Thickness In Floors, Aprons Etc Laid Dry Or Bedded And Pointed In Any Mortar Complete All As Specified And As Directed By Engineer-In-Charge. 128 Demolition Of Cement Concrete Reinforced Of Any Discription And In Any Position, Including Reinforcement Cut As Required To Facilitate And Including Removing Rubbish Material From Building And Thrown In Low Lying Empty Area (As Per Direcction Of Age/Je) At Any Distance Upto 500 Metres From The Site Complete All As Specified And As Directed By Engineer-In-Charge. Note:The Weight Of Scrap Iron For Schedule Of Credit Shall Be Ascertain By Boo As Ordered By Ge.The Copy Of Boo Duly Countersinged By Ge Shall Be Enclosed With Final Bill. 129 Material And Labour For Reinforced Cement Concrete, Nominal Mix,1:2:4, Type-B1, Using 20 Mm Graded Stone Aggregate As In Slabs Supported On Walls, Beams And Columns In Floors, Roofs, Landings, Balconies, Canopies, Deck Slabs And In Shelves And The Like Including Proper Compaction By Using Mechanical Viberator Complete All As Specified And Directed. Note : Reinforcement And Form Work Shall Be Measured And Paid For Separately Under Appropriate Item Of This Schedule. 130 Supply And Fixing Pvc (Hdpe) Swr, 110 Mm Bore, Single Socketed In Any Length With Rubber Ring Joints Using Solvent As Per Manufacture Instruction, Fixed To Walls Complete All As Specified Including Fixing Of Pipe To Wall With Flat Irons Clamps Of Size 25 X 3 Mm, Bolts, Washers, Nuts, Nails Etc, After Taking Down Existing Damaged Rain Water Pipe Complete All As Specified And Directed 131 Material & Labour For In Repair 75 Mm Dia Pvc (Swr) Floor Trap Type B , Plain With Grating Including Jointing With Solvent Complete All As Specified And Directed By Engineer-In-Charge. 132 Material & Labour For 100 Mm Dia Pvc (Swr) Floor Trap Type B , Plain With Grating Including Jointing With Solvent Complete All As Specified And Directed By Engineer-In-Charge. 133 Material And Labour For Water Proofing Tratment To Roof / Terrace (Material Of Water Proof Treatment As Approved By Ge) Single Component, Acrylic Based, Flexible, Micro Fibre Reinforced Waterproofing And Heat Reflective Coating System. The Treatment Shall Be Carried Out As Per The Manufacturers Instructions And Shall Include The Followings:(A) Preparation Of Substrate And Cleaning It Off All Loose And Triable By Mechanical Means(B) Open The Cracks Lines To Form , V Grooves With Cutter/Hammer/Chisel Up To 5-10Mm And Filling With Crack Filler And Pu Sealant.(C) Application Of Primer Coat @ 0.2 To 0.3 Kg/ Sqm Followed By The First Coat @ 0.75Kg/ Sqm.(D) The Second Coat Shall Be Applied @ 0.75 Kg / Sqm And Reinforced With Fabric Re-Inforcement Between The First And Second Coat.(E) The Top Coat Of Primer Shall Be Applied After The Second Coat Dries Off @ 0.05-0.08 Kg Per Sqm.(F) The Material Shall Adhere To Following Specification. Technical Specification Of Materialtensile Strength 1.5 Mpa Astm D412Elongation At Break > 200% Astm D412Adhesion In Peel > 1.5 Mpa (On Concrete Substrate) En 1542Crack Bridging Ability Passes Upto 3.2Mm Width Astm C1305Permeability To Water Vapour Passes Is 2645Water Vapour Transimission ~ 23 G/M²/24Hr Astm E96Water Absorption 134 Material And Labour For 40Mm Average Thick Pcc Padding In 1:2:4 Type B-1 (Using 20Mm Graded Stone Aggregates) As In Roof Slab Finishing The Surface Even And Fair Using Liquid Water Proofing Compound Complete All As Specified And Directed. Liquid Water Proofing Compound Shall Be Measured And Paid Separetly As Supply Only Under Appropriate Item Of Schedule A Boq. 135 Material And Labour For Making Benching With Pcc 1:2:4 Type- B0, Using 12.5Mm Graded Stone Aggregates Using With Liquid Water Proof Compound As Per ManufacturerS Instruction Along Side Wall Adjoining To Roof In Concave Shape Complete All As Specified And Directed. Note : Liquid Water Proofing Compound Shall Be Measured And Paid Separetly As Supply Only Under Appropriate Item Of Schedule A Boq. 136 Material And Labour For Cement Concrete 1:2:4 , Type B-2 Using 40 Mm Graded Stone Aggregate As In Foundation Filling And Mass Concrete Complete All As Specified And As Directed By Engineer-In-Charge. 137 Material And Labour For Water Proofing Compound Complete All As Specified And Directed. 138 Supply And Laying Dwcpe (Sn 8) Drain Pipes 150 Mm Nominal Dia As Per Is-16098 (Part-Ii), Laid In Trenches On Bed Including All Accessories/ Fittings/ Jointed Ring, Jointing And Testing Complete All As Specified And As Directed By Engineer-In- Charge.Note:- Excavation , Earth Work, Bedding And Pedestal / Anchorage If Required Shall Be Measured And Paid Separately Under Appropriate Item Of Boq/ Sch A 139 Material And Labour For Pcc (1:3:6) Type C-2 Using 40 Mm Graded Stone Aggregates As In Concrete Bed Of Sgsw Drain Pipes Of 150 Mm Bore, Laid To Required Slope Including Packing Under And Haunching Against The Sides Of Pipes After They Are Laid And Tested Complete All As Specified And As Directed By Engineer-In-Charge. Note :- (I) Thickness Of Concrete Bed Below The Barrel Of Pipe Shall Be 10 Cm. (Ii) Width Of Concrete Bed Shall Be Outer Diameter Of Drain Pipes (Not Of Sockets / Collar) Plus 30Cm. 140 Material & Labour For Antitermite Treatment Along The External Wall Below Concrete Or Masonry Apron Using Chemical Emulsion @ 2.25 Litres Per Linear Metre Including Drilling And Plugging Holes Etc. In Apron/Plinth Etc., Complete All As Specified And As Directed By The Engineer-In-Charge. 141 Material And Labour For Att At Points Of Contact Of Wood Work By Chemical Emulsion (In Oil Or Kerosene Based Solution) @ 0.5 Litre/Hole By Drilling 6Mm Dia Holes At A Downward Angle Of 45 Degree At 150Mm Centre To Centre And Sealing The Same Complete All Sepecified And Directed By Engineer-In-Charge. 142 Material And Labour For Att Of Soil Under Existing Floors Using Emulsion @ One Liter Per Hole, 300Mm Apart Including Drilling And Plugging 12Mm Dia Holes With Cement Mortar 1:2 (1 Cement :2 Coarse Sand) To Match The Existing Floors Complete All Sepecified And Directed By Engineer-In-Charge. 143 Material And Labour For Writing Letters Or Figures (Block,Roman, Italic Ot Indian) Of Any Description, Not Exceeding 30Cm High With Paint Complete All Sepecified And Directed By Engineer-In-Charge. 144 Material And Labour For Cutting Into Existing Manholes For Connecting New Drains, Making Good To Pipe And Rendering, Cutting Out Existing Benching For And Forming Branch Channel (1/2 Round Or 3/4 Section) In Cement Concrete 1:2:4 Type B-L Smooth Finished, And Reforming Benching As Required For Internal Dia Of Pipe In 150 Mm Complete All As Specified And As Directed By Engineer-In-Charge. 145 Taking Down Cement Or Cement Lime Plaster On Brick Or Stone Walls, Etc. Including Raking Out Joints, Hacking For Key, Scrubbing Down With Water, Etc. Complete All As Specified And As Directed By Engineer-In-Charge. 146 Material And Labour For 15Mm Thick Rendering In Cm (1:6) (Internal Surface) On Other Than Fair Faces Of Brick Work Or Concrete Surfaces And Finishing Even & Smooth But Without Using Extra Cement Complete All As Specified And As Directed By Engineer-In-Charge. 147 Material And Labour For Factory Made,Machine Pressed Precast Interlocking Paver Block 60 Mm Thick With Grey Cement And No Pigment, Any Shape And Size, Conforming To Is 15658-2006, Made Out Of M-35 Grade Concrete Laid Over Sand Cushioning Complete All As Specified And As Directed By Engineer-In- Charge. Note: The R Sand Cushioning Shall Be Measured And Paid Seperately Under Appropriate Item Of Schedule A Boq. 148 Dismantling Of Brick Tiles Or Terracing Tiles Single Layer On Roof & Disposal Of Retrieved Material Upto A Distance N.Exc 100M Where Directed, Complete All As Specified And Directed By Engineer-In- Charge. 149 Demolition Of Mud In Roofs, Any Thickness, Including Plastering And Leeping (Whether Full Thickness Removed Or Only A Part Thereof Disposal Off Rubbish Upto A Distance Not Exceedomg 500.00Mtr Where Directed ) Complete All As Specified And Directed By Engineer-In- Charge. 150 Material And Labour For 15Mm Thick Screed Bed Or Bedding Layear In Cement Mortar 1:4 On Roof Surfaces, Parapet Or Vertical Beam Surface (Horizontal Or Vertical) Finishing The Surfaces Even And Fair Complete All As Specified And Directed By Engineer-In-Charge. 151 Supply And Fixing Anodised Aluminium Handle, Fabricated Type 150Mm Long Complete All As Specified & Directed By Engineer-In-Charge. 152 Supply And Fixing Aluminium Anodised Barrel Tower Bolt Of Extruded Section, 200Mm Long Complete All As Specified & Directed By Engineer-In-Charge. 153 Supply & Fixing Aluminium Anodised Sliding Door Bolts 300Mm Long, With Hasp And Staple (Bolt Type) And Fixing Clips Of Sheet, Cast Or Extruded Sections And Fixing Bolts And Sliding Bolts Of Extruded Sections Or Cast-Aluminium Alloy And Fixed Complete All As Specified & Directed By Engineer-In- Charge. 154 Supply & Fixing Factory Made Steel Window Confirming To Is 1038 With Side Hung Shutters Including Projecting Type Hinges, With Steel Handle, Steel Peg Stay, Complete, Dovetailed Welded, With And Including One Shop Coat Of Zinc Chromate Primer Without Glazing Bars Including Making Good As Per Existing Surfaces Complete All As Specified & As Directed By Engineer-In- Charge.Note: The Rate Of One Shop Coat Of Zinc Chromate Primer Is Included In This Item And Nothing Shall Be Paid Extra On This Account. 155 Supply & Fixing Factory Made Steel Window Confirming To Is 1038 With Side Hung Shutters Including Projecting Type Hinges, With Steel Handle, Steel Peg Stay, Complete, Dovetailed Welded, With And Including One Shop Coat Of Zinc Chromate Primer With Glazing Bars Including Making Good As Per Existing Surfaces Complete All As Specified & As Directed By Engineer-In- Charge.Note: The Rate Of One Shop Coat Of Zinc Chromate Primer Is Included In This Item And Nothing Shall Be Paid Extra On This Account. 156 Supply Only 3.00 Mm Thick Sheet Glass Ordinary Quality ,Fixing With Oil Putty To Wooden Or Steel Surface N.Exc 0.5 Sqm Each Complete All As Specified And Directed 157 Material & Labour For Excavating In Post Holes (Or Similar Holes) Each N Exc 0.5 Cu. M, Getting Out, Returning, Filling In And Ramming Earth Or Broken Rubble Mixed With Earth Around, In Layers Not Exceeding 25 Cm, In Soft / Loose Soil Complete All As Specified And Directed By Engineer-In- Charge. Complete All As Specified And Directed By Engr-In-Charge. 158 Supply And Fixing For Mild Steel Screw Bolts 5Mm To 10Mm Dia Of Neck (Machine Made) With Hexagonal Or Square Heads At One End And Screwed The Other, Or Screwed Both Ends, Each Screwed End To Be Fitted With Washers And One Hexagonal Or Square Nut, Length Of Bolt Exc 5Cm But N Exc 10Cm Long Complete All As Specified And Directed By Engr-In-Charge. 159 Supply And Fixing For Pre -Painted Galvalume Aluminium Zinc Coating Gi Based Corrugated Steel Sheet 0.50Mm Thickness Of Any Colour Having Atensile Strength Of 550 Mpa As In Roof Covering Fixed With L Type Or J Type Or Cranked Hook Bolts All As Specified And Directed By Engineer-In-Charge. 160 Material And Labour For Roof Trusses (Framed), Trussed, Purlins, Crane Gantries, Rails And Fastenings And Heavy Bracket Framing (Beam, Tee, Angle, Channel Or Flat Sections) Including Distance Pieces, Cleats Etc Complete All As Specified And Directed By Engr-In-Charge. 161 Material And Labour For Steel Work In Tubular Post 100Mm Dia Including Special Shaped Washer Etc. Complete Using Erw Or Induction Butt Welded Tubes Conforming To I. S.1161- 1979 Grade St.-240 Including Rolled Mild Steel Joist, Channel, Angle, Or Tee Sections, Fixed Independently, Without Connecting Plates, Etc. (Cut To Ordinary Lengths I.E. Within 20Mm Of The Length Indicated Of Gde Fe 410 -S, Complete All As Specified And Directed By Engr-In-Charge. 162 Supply And Fixing In Repairs Magic Eye For Flush/Panelled Door Shutter Etc Complete All As Specified And As Directed By Engineer-In-Charge. 163 Supply And Fixing Framed Work As In Doors Or Gates Of Angle Or Other Section With Gusset Plates, Rails, Braces, Etc., Complete, Drilled For Fixing Of Steel Sheeting Or Other Covering. Doors, Etc. To Be Prepared For Hanging Or Sliding With And Including Either Hooks And Hinges Or Steel Hanging Door Fittings (Exclusive Of Steel Sheeting Or Other Covering, Running Rails And Guides) Andhanging; Also Fastening And Fixing Complete Complete All As Specified And Directed By Engineer-In -Charge. 164 Material And Labour For Preparation Of New Steel Surfaces Of Any Description Over 10Cm Width Or Girth And Applying Two Coats Of Synthetic Enamel Paint Over With And Including One Coat Of Red Oxide Zinc Chrome Primer Complete All As Specified And As Directed By Engineer-In-Charge. 165 Material And Labour For Preparing Old Steel Surfaces Of Any Description Over 10 Cm Width Or Girth And Applying One Coat Of Synthetic Enamel Paint Complete All As Specified And As Directed By Engineer-In- Charge. 166 Dismantling Boarding, Any Description, Fixed In Any Position With Nails Complete All As Specified And As Directed By Engineer-In- Charge. 167 Supply & Fixing 18Mm Thick Hdhmr Board Uv Coating, Exterior Grade As Approved By Ge, With And Including Acrylic High Gloss Sheet Of Min 1Mm Thick Over Hdhmr Board, Anti Fungal, Moisture Resistance, Anti Borer, As Per Is 14587 For Frame And Shutter For Kitchen Cabinets / Cupboards (Such As Side Wall, Shutter, Partition Back Side Of Etc. Of Cupboard And Cabinets). Complete All As Specified And Directed By Engg-In-Charge. 168 Supply & Fixing In Repairs Of Stainless Steel Cabinet / Drawers Handle Having A Length Of 250Mm And Shape Complete All As Specified And Directed. 169 Supply & Fixing In Repairs Of Partial Overlay / Fully Overlay Hydraulic Self Closing Concealed Hinges Having Size 103Mm X 64Mm Finish Of Nickel/Silver As Approved By Ge Complete All As Specified And Directed By Engg-In-Charge. 170 M&L For 40Mm Gi Pipe Medium Grade Made To Shape As In Spout Pipe As In Sunken /Verandah/ Balconey Complete All As Specified And As Directed. 171 Supply And Laying Or Fixing Or Laid In Trenches/ Ducts/ Through Pipes/ In Floors / Under Roads/ Hard Standing /Along Poles And Testing Lt Cable Xlpe, Pvc Insulated Screened, Bedded, Galvanised Steel Strip Or Wire Armourd Cable (Heavy Duty) 1100 Volt Grade With Aluminium Conductor Having Cross Sectional Area 70 Sqmm X 3.50 Core Conforming To Is-7098 (Part-I -1988) Complete All As Specified And As Directed By Engineer-In-Charge. (Excavation And Earth Work, Sand Cushioning & Gi Pipe Shall Be Measured And Paid For Separately) 172 Taking Down Carefully Copper /Aluminium Point Wiring (Light, Fan, Socket Or Power Point ) Complete Including Fitting Such As Hylem , Sheet Switches, Ceiling Rose, Pendent Holder , Sockets, Fan Regulator , Bell Push, Electronic Bell , Sunken Box Except Concealed Conduit Etc. Complete All As Specified And Directed By Engineer-In-Charge. Notes:(I) The Weight Of Aluminium Scrap , Copper Scrap And Iron Scrap Shall Be Ascertained By Boo As Ordered By Ge And Same Duly Countersinged By Ge Shall Be Enclosed With Final Bill. (Ii) The Rate Of Cutting Chases (As Required) And Making Good Surfaces To Match With Adjoining Surface Shall Be Measured And Paid Seperately Under Serial Item No. 173.00, 174.00, 175.00, 176.00, 177.00, 178.00, 179.00, 180.00, 181.00, 182.00, 183.00, & 184.00 Of Boq. 173 Material And Labour Point Wiring For One Light / Fan Point Controlled By 6 Amps One Way Modular Switch Switch With 2.5 Sqmm Pvc Insulated, Unsheathed Multi Strand Copper Conductor Cable Fr-Lsh In And Including Concealed Pvc Conduit 20 Mm Dia Heavy Duty Isi Marked, Steel Terminal Sunken Boxes And 3 Mm Thick Phenolic Laminated Sheet Top Cover For Sunken Boxes Flush To Surface For One Light Point/Fan Point, Controlled By One Switch On The Same Board With Other Switch Or Independent Including Cutting, Chasing The Surface And Then Making Good The Same In Cm (1:3) Complete All As Specified And Directed By Engineer-In-Charge. (Note:- Switches, Sockets Etc Shall Be Measured And Paid For Separately Under Items Of Schedule). 174 Material And Labour Point Wiring For One Light / Fan Point Controlled By 6 Amps Two Way Modular Switch Switch With 2.5 Sqmm Pvc Insulated, Unsheathed Multi Strand Copper Conductor Cable Fr-Lsh In And Including Concealed Pvc Conduit 20 Mm Dia Heavy Duty Isi Marked, Steel Terminal Sunken Boxes And 3 Mm Thick Phenolic Laminated Sheet Top Cover For Sunken Boxes Flush To Surface For One Light Point/Fan Point, Controlled By One Switch On The Same Board With Other Switch Or Independent Including Cutting, Chasing The Surface And Then Making Good The Same In Cm (1:3) Complete All As Specified And Directed By Engineer-In-Charge. (Note:- Switches, Sockets Etc Shall Be Measured And Paid For Separately Under Items Of Schedule). 175 All As Per Item No 174.00 Here- In -Before But For One 3/5 Pin, Modular Socket Outlet 6 Amp, On Same Board Complete All As Specified And As Directed By Engineer-In- Charge. 176 All As Per Item No 17400 Here- In -Before But For One 3/5 Pin, Modular Socket Outlet 6 Amp, On Independent Board Complete All As Specified And As Directed By Engineer-In- Charge. 177 All As Per Item No 174.00 Here- In -Before But For One 3/5 Pin, Modular Socket Outlet 5/15 Amp, On Independent Board Complete All As Specified And As Directed By Engineer-In- Charge. 178 All As Per Serial Item No 174.00 Of Boq Here-In-Before But For Modular Bell/Buzzer Point Controlled By One Push Button On Independent Board But Not Below The Switch Board, Complete All As Specified And Directed By Engineer-In-Charge. 179 All As Per Serial Item No 174.00 Of Boq Here-In-Before But For Modular Socket Outlet 3 Pin 6 Amp On Independent Board Complete All As Specified And Directed By Engineer-In-Charge. 180 All As Per Serial Item No 174.00 Of Boq Here-In-Before But For 15/16 Amp Socket Out Let By Using 2.5 Sqmm Pvc Insulated Unsheathed Copper Conductor Cable Fr-Lsh Multi Strand On Independent Board Including Provn 2.5 Sqmm Unsheathed, Multi Stranded Copper Conductor Cable Fr-Lsh Continues As Earth Wire Connected To Earth Dolly Etc Complete In Existing Conduit Complete All As Specified And As Directed By Engineer-In-Charge. 181 Material And Labour For Point Wiring For One Light / Fan Point Controlled By One Switch With 1.5 Sqmm (Nominal Area) Pvc Insulated Unshealthed Multi Stranded Copper Conductor Cable Fr-Lsh In Existing Conduit And Provision Sunken Boxes But Inclyding 3 Mm Thick Phenolic Laminated Sheet Top Cover For Sunken Boxes Flush To Surface For One Light Point/Fan Point Controlled By One Switch And Fan Regulator Including Pvc Insulated Unshealthed 1.5 Sqmm Copper Conductor Cable Fr-Lsh Connected To Common Earth Dolly Complete All As Specified And Directed 182 All As Per Srl Item No 181.00 (Here-In-Before) But Socket 3 Pin 5 Amp 230 Volt Flush Type On Same Board 183 All As Per Srl Item No 181.00 (Here-In-Before) But For One Socket Point Outlet 3 Pin 5 Amp In Incdependent Board 184 All As Per Serial Item No 181.00 Of Boq Here-In-Before But For 15 Amp Socket Out Let By Using 1.5 Sqmm Pvc Insulated Unsheathed Copper Conductor Cable Fr-Lsh Multi Strand On Independent Board Including Provn 2.5 Sqmm Unsheathed, Multi Stranded Copper Conductor Cable Fr-Lsh Continues As Earth Wire Connected To Earth Dolly Etc Complete In Existing Conduit Complete All As Specified And As Directed By Engineer-In-Charge. 185 Supply And Fixing Switch Piano, Flush Type Single Pole, One Way 5 Amp Complete All As Specified 186 Supply And Fixing Switch Piano, Flush Type Single Pole, One Way 15 Amp Complete All As Specified 187 Supply And Fixing Socket Outlet 3 Pin, 5 Amp Flush Type All As Specified 188 Supply And Fixing 2 In 1, 3 Pin, 5 And 15 Amp Flush Type Complete All As Specified 189 Supply And Fixing Modular Switch One Way , 6Amp/10Amp ,1 Module, Single Pole, 250 Volts ,Ac Supply, Isi Marked , Complete All As Specified And Directed By Engineer-In-Charge 190 Supply And Fixing Modular Socket Outlet , 6 Amp-2/3 Pin Combined 2 Module , 230 Volts , Multipurpose, Ac Supply, Isi Marked Complete All As Specified And Directed By Engineer-In-Charge. 191 Supply And Fixing Modular Switch One Way 16 Amp, Single Pole, 1 Module 230 Volts , Ac Supply , Isi Marked Complete All As Specified And Directed By Engineer-In-Charge. 192 Supply And Fixing Modular Switch Two Way 6 Amp, Single Pole, 1 Module 230 Volts , Ac Supply , Isi Marked Complete All As Specified And Directed By Engineer-In-Charge. 193 Supply And Fixing Modular Bell Push Switch 6A 1 Module , Isi Marked Complete All As Specified And Directed By Engineer-In-Charge.Note: (I) Labour Element For Taking Down Old Unservicable Material Is Included In Serial Item No.172.00 Of Boq Here-In -Before And Nothing Shall Be Extra Paid On This Account. 194 Supply And Fixing Modular Socket Outlet 6Amp/16Amp-2/3 Pin Combined,2 Module ,230 Volts ,Multi Purpose, Ac Supply, Isi Marked Complete All As Specified And Directed By Engineer-In-Charge. 195 Supply And Fixing Fan Regulator, Modular Type, 5 Step, High Speed, Two Module Complete All As Specified And Directed By Engineer-In-Charge. 196 Supply And Fixing Ceiling Rose 3 Terminal Flush Type 6 Amp 250V ,Isi Marked ,Ac Supply, Topline Series With Polycarbonate 20Mm X 50 Mm Two To Three Terminal, Complete All As Specified And Directed By Engineer-In-Charge. 197 Supply And Fixing Electric / Electronic Bell, Ding Dong Type 230 Volt Ac Supply,Isi Marked Complete All As Specified And Directed By Engineer-In-Charge. 198 Supply And Fixing Wall Mounted Extruded Aluminium/Polycarbonate Led Batten Fixture T8(G13 Holder) 1.2 M Including One Led Retrofit Tube 20(±10) Watt. 1.2 M T8 6500 Efficacy Not Less Than 90 Lumen/Watt Extruded Aluminium/Polycarbonate, Pc Diffusor And Inbuilt Driver Complete Including Making Connection Complete All As Specified And Directed 199 Supply And Fixing Lamp Holder ,Isi Marked Of Pvc/Polycarbonate Type With Back Plate Suitable For Batten Fitting With And Including 9Watt Led Retrofit Lamp (Base B-22) Complete All As Specified And Directed By Engineer-In-Charge. 200 Supply And Fixing Lamp Holder Pvc/ Polycarbonate Type With Back Plate Suitable For Batten Fitting With Led Bulb 5 Watt Lamp Base- B-22 Complete All As Specified And As Directed By Engineer-In- Charge.Note: Labour Element For Taking Down Old Unservicable Material Is Included In Serial Item No.172.00 Of Boq Here-In -Before And Nothing Shall Be Extra Paid On This Account. 201 Supply Only Led Bulb 9 W (Suitable For B22 Base), 250V Ac, Green/Red/ Clear Day Light ( Cdl) In Colour Complete All As Specified And Directed By Engineer-In-Charge.As Per Direction Of Engineer-In-Charge Colour Of Led Luminiure Cdl/Warm White Shall Be Provided By The Contractor As Per Site Requirment And Nothing Shall Be Paid Extra On This Account.Notes:(A) Contractor Has To Furnish A Replacement Warranty Of 02 Years For Led Bulb Complete Including Lamp/ Strip From The Certifiy Date Of Completion Of Ca. The Product Will Be Replaced Free Of Cost In The Following Case :-(I) Manufacturing Defects.(Ii) Failure Due To Mechanical And Electrical Impact. (Iii) Drop In Lumen (Or Lux At 1 M) Below 90% Of Clamied Values Of Lumen(Or Lux At 1 M) Of The Led Bulb . (B) All Led Bulbs Must Meet The Provision Laid Down In Is - 16101, 16102 Part -I/Ii,16103 Part -I, 16104,16105,16106, 16108/2012 And 15885 Part -Ii / Section 13. (C) Scope Of Work Shall Include To Fix Led Bulb Walls/Ceiling Which Includes Needful T & P And Required Accessories Etc If Any, Complete Including Making Connection, Testing Etc Complete. No Extra Payment Is Admissible On These Account.(D) Old Unservicable Retrieved Material Shall Be Deposited In The Store Yard Of Age E/M Ge (North) Bathinda By The Contractor His Own Arrangements And Nothing Shall Be Paid Extra On This Account. (E) The Rate Of Electric Connection Connecting With Using Flexible Copper Wire Twin Core Upto Ceiling Rose/Connector Is Included In This Item And Nothing Shall Be Paid Extra On This Account. 202 Supply And Fixing In Replacement Led Panel Light Fitting Recessed Mounted,Square Shaped Of Size 600Mm X 600Mm , 36 (±10%) Watt, Efficacy Not Less Than 100 Lumen/Watt , Extruded Aluminium/Polycarbonate, Pc Diffusor And Inbuilt Driver Complete As Per ManufacturerS Instructions With And Including Connection With Flexible Twin Core Copper Cable Of Size 23/.00076 From Ceiling Rose To Fitting Complete All As Specified And As Directed By Engineer-In- Charge. 203 Material And Labour In Replacement Sub Main Wiring Complete With Two Single Core 6 Sqmm,1100 Volts Grade, Pvc Insulated, Multi Stranded Copper Conductor Cable Frlsh With And Including Single Core 6 Sqmm,1100 Volts Grade, Pvc Insulated, Multi Stranded Copper Conductor Cable Frlsh For Earth Wire In Existing Pvc Concealed Conduit (Colour Code Phase-Red, Neutral-Black And Earth As Green) Complete All As Specified And Directed By Engineer-In-Charge. Notes:-(A) Three Single Core 6 Sqmm Frlsh Pvc Insulated Unsheathed With Multistranded Copper Conductor Cable 1100 Volts Grade Shall Be Measured As One Length. 204 Supply And Fixing In Replacement Mcb 40Amp -63 Amp Spn ,240Volt , Rupturing Capacity 10 Ka , Curve ‘C’ Isi Marked, Complete All As Specified And Directed By Engineer-In-Charge. 205 Supply And Fixing In Replacement Mcb 6Amp -32 Amp Sp ,240Volt , Rupturing Capacity 10 Ka , Curve ‘C’ Isi Marked, Complete All As Specified And Directed By Engineer-In-Charge. 206 Supply And Fixing In Replacement Mcb 32 Amp Spn ,240Volt , Rupturing Capacity 10 Ka , Curve ‘C’ Isi Marked, Complete All As Specified And Directed By Engineer-In-Charge. 207 Supply And Fixing In Replacement Sheet Metal Enclousers Made Out Of Crca Mild Steel Sheet Not Less Than 1.2Mm Thick,, Double Door, Powder Coated Db Spn 8 Way 240 Volt, Ip -54, 200 Amps Rated Bus Bar, Dust And Vermin Proof Suitable For Incorporation Of McbS And Isolators Etc Complete All As Specified And As Directed By Engineer-In- Charge.Note: Mcb/ Isolators Shall Be Measured And Paid Seperately Under Appropriate Item Of Boq. 208 Supply And Fixing Sheet Metal Enclousers Made Out Of Crca Mild Steel Sheet Not Less Than 1.2Mm Thick,, Double Door, Powder Coated Db Spn 12 Way 240 Volt, 200 Amps Rated Copper Bus Bar, Dust And Vermin Proof Suitable For Incorporation Of McbS And Isolators Etc Complete Complete All As Specified And As Directed By Engineer-In- Charge.Note: Mcb/ Isolators Shall Be Measured And Paid Seperately Under Appropriate Item Of Boq. 209 Supply And Fixing In Replacement Sheet Metal Enclousers Made Out Of Crca Mild Steel Sheet Not Less Than 1.2Mm Thick,, Ip-54 Protection, Flush Mounted For Metal Door, Powder Coated Db Tpn 4 Way, 415 V Ac With 63 Amps Rated Bus Bar, Double Door, Dust And Vermin Proof Suitable For Incorporation Of Incoming Mccb And Outgoing Mcb Sp/Tp And Earth & Neutral Bus Bar Etc Complete All As Specified And As Directed By Engineer-In- Charge.Note: Mcb/ Isolators Shall Be Measured And Paid Seperately Under Appropriate Item Of Boq. 210 Supply And Fixing Wall Mounted Extrdued Aluminium Housing Led Betten Fixture With Tube 1.2 M, 20 Watt Inverter Type, 1.2 M 3000/6500K, Efficacy Not Less Than 90 Lumen/Watt, Extruded Aluminium/Polycarbonate, Pc Diffusor And Integrated Inbuilt Driver Complete Including Making Connection Complete All As Specified And As Directed By Engineer-In- Charge. 211 Supply And Fixing Wall Mounted Extrdued Aluminium Housing Led Betten Fixture With Tube 1.2 M, 25 Watt Inverter Type, 1.2 M 3000/6500K, Efficacy Not Less Than 90 Lumen/Watt, Extruded Aluminium/Polycarbonate, Pc Diffusor And Integrated Inbuilt Driver Complete Including Making Connection Complete All As Specified And As Directed By Engineer-In- Charge. 212 Supply And Fixing Led Batten Fitting 1X10 Watt, 6500K, 2 Ft Complete With Decorative Ultra Slim Square Profile Led Lighting Fixture With Extruded Polycarbonate Environment Friendly, Energy Efficient Complete With All Light Connection All As Specified And Directed 213 Supply And Fixing In Repair Led Street Light Fitting 35 Watt 230 V Ac Outdoor Type With High Pressure Die Cast Aluminium Hosing And Heat Resistant Complete With Driver, Lamp Bracket With Impact And Corrosion Resistant Complete With Ip 65/66 Protection Including Fixing With Gi/Ms Bracket Made Out Of Suitable Size Of Light Grade Tube Upto 1.2 Mtr Length Bent To Shape With 02 Sets Of Ms Clamps Made Out Of Minimum 3 Mm Ms Flat Iron With Iron With Suitable Bolt And Nuts Complete With Making Connection Complete All As Specified And Directed 214 Supply & Fixing Building Security Led Light Of 35 Watt , Ip 66 , Luminaire With High Power With Toughened Glass Complete As Per ManufacturerS Instructions With And Including Bracket Made Out With 40Mm Bore Galvanised Iron Light Grade Pipe 1.20 Mtr Length Bent To Shape With 02 Sets Of Ms Clamps Made Out Of Minimum 3 Mm Ms Flat Iron With Suitable Bolt ,Nuts And Washers Complete And Fixing To Wall / Column With And Including Electrical Connection With 1.5 Mtr Long Twin Core Round Copper Conductor Cable Of Suitable Size And Testing Complete All As Specified And Directed By Engineer-In-Charge. Notes:(A) The Rate Of Bracket Made Out With 40Mm Bore Galvanised Iron Light Grade Pipe 1.20 Mtr Length Bent To Shape With 02 Sets Of Ms Clamps Made Out Of Minimum 3 Mm Ms Flat Iron With Suitable Bolt And Nuts And Electrical Connection With 1.5 Mtr Long Twin Core Round Copper Conductor Cable Of Suitable Size Is Included In This Item And Nothing Shall Be Paid Extra On This Account. (B) Contractor Has To Furnish A Replacement Warranty Of 02 Years For Security Led Light Fittings Complete Including Lamps From The Certifiy Date Of Completion Of Ca. The Product Will Be Replaced Free Of Cost In The Following Case :-(I) Manufacturing Defects.(Ii) Failure Due To Mechanical And Electrical Impact. (Iii) Drop In Lumen (Or Lux At 1 M) Below 90% Of Clamied Values Of Lumen(Or Lux At 1 M) Of The Led /Luminaries. (C) All Security Led Light Must Meet The Provision Laid Down In Is - 16101, 16102 Part -I/Ii,16103 Part -I, 16104,16105,16106, 16108/2012 And 15885 Part -Ii / Section 13. (D) Scope Of Work Shall Include To Fix Security Led Light Fittings Walls/Building Which Includes Needful T & P And Required Accessories Etc If Any, Complete Including Making Connection, Testing Etc Complete. No Extra Payment Is Admissible On These Account. 215 Supply And Fixing Jointing Of Double Walled Corrugated Pipe (Dwc) As Ug Cable Protection Complete Of Size 63 Mm, Complete All As Specified And Directed By Engineer-In-Charge 216 Supply And Fixing Jointing Of Snap Fit Coupler For Double Walled Corrugated Pipe (Dwc) Of Ug Cable Protection Complete Of Size 63 Mm, Complete All As Specified And Directed By Engineer-In-Charge 217 Supply And Fixing Mccb With Adjustable Type, 4 Pole, 63 Amps, 415 Volts, 50 Hz, 25 Ka And Including Sheet Metal Enclosure Out Door Type Made Out Of 3.15 Mm Thick Crca Sheet Mounted On Angle Iron Padesta Including Grouting Complete All As Specified And Directed By Engineer-In-Charge. 218 Material And Labour For Earthing Complete With Galvanised Steel Earth Plate Electrode 600Mm X 600Mm X 6 Mm Thick Burried Directly In Ground To Depth Of Pit Not Less Than 2.25 M Below Normal Ground Level With Top Edge Of The Plate Not Less Than 1.5 M Below Normal Ground Level Surrounded From All Sides By 15 Cm Thick Packed Layer Of Charcoal / Coal Dust And Common Salt Filling In Alternate Layers And Connected To Galvanised Earth Lead Wire 4 Mm Dia By Means Of Bolts, Nuts, Check Nuts And Washers Of Gi Or Steel Including Gi Protection Pipe 15Mm Dia Light Grade Upto The Extent Of 7.5 Metre And Connecting To Earthing Test Point, Main Switch Board Including Gi Pipe 20 Mm Dia Light Grade For Watering, Ms Funnel And Bringing Out The Watering Pipe Upto 30 Cm Above The Normal Ground Level Plugged At Top Including All Fitting Including Pcc Earth Pit With Pcc 1:2:4 Type B-1 Using 20Mm Graded Stone Aggregate And Rcc Pit Cover Including Necessary Earthwork And Excavation In Any Type Of Soil Complete All As Specified As Shown In Electrical Plate No 3 Of Ssr Part-I And Testing On Completion. Note:- (I) Earth Continuity Of Gi Wire 4 Mm Including Protection Pipe Up To 7.5 Mtrs From Earth Electrode Will Be Included In Unit Rate, Complete All As Specified And Directed. (Ii) The Rate Of Earth Work In Soft/Loose Soil I.E. Excavation, Returing Filling And Removal, Form Work Is Included In This Item And Nothing Shall Be Paid Extra On This Account. (Iii) Pcc Chamber Shall Be Constructed At Least 1.5 Metre Away From The Earth Electrode And Pipe For Watering Shall Be Provided In Slanting Manner. (Iv) The Earth Testing Arrangement Should Be Done By The Contractor As Per Direction Of Engineer-In-Charge. 219 Supply And Fixing 1100 Volts Grade Heavy Duty Cable Pvc Insulated Aluminium Strandred Conductor 6Sqmm, Served With Inner Sheathing Of Pvc Tape And Overall Pvc Sheathed In Service Connections Suspended By Insulating Hangers Not More Than 1 Mtr Apart Including 4Mm Suspenstion Wire, One Twin Core Cable Flat All As Specified And Directed 220 Supply And Fixing In Replacement Exhaust Fan 300Mm Sweep (Heavy Duty) Steel Body, Bee, 5 Star Rated ,Ac Supply, Single Phase ,230 Volts, 50Hz,1200Rpm With And Including Frame Including New Mosquito Stainless Steel Wire Mesh Of Guage 0.36Mm With Suitable Wooden Frame Protection Against Birds Etc. Mounted In Suitable Opening Arrangmement In Wall And Electric Connection With And Including Three Core Pvc Insulated Pvc Sheathed Copper Conductor Flexible Cable 24/0.2Mm Drawn In Flexible Pvc Conduit And Hanging On Wall With 04 Nos. Steel Fastners 10Mm Dia 100Mm Long With And Including Serial Number Of Fan As Issued By Engineer-In-Charge And Ge Office Name With Red Colour Permaent Marker Complete All As Specified And Directed By Engineer-In-Charge. 221 Supply And Fixing Exhaust Fan 250Mm Sweep (Heavy Duty) Steel Body, Bee, 5 Star Rated ,Ac Supply, Single Phase ,230 Volts, 50Hz,1200Rpm With And Including Frame Including New Mosquito Stainless Steel Wire Mesh Of Guage 0.36Mm With Suitable Wooden Frame Protection Against Birds Etc. Mounted In Suitable Opening Arrangmement In Wall And Electric Connection With And Including Three Core Pvc Insulated Pvc Sheathed Copper Conductor Flexible Cable 24/0.2Mm Drawn In Flexible Pvc Conduit And Hanging On Wall With 04 Nos. Steel Fastners 10Mm Dia 100Mm Long With And Including Serial Number Of Fan As Issued By Engineer-In-Charge And Ge Office Name With Red Colour Permaent Marker Complete All As Specified And Directed By Engineer-In-Charge. 222 Taking Down Unserviceable Complete Ceiling Fan Along With Blades And Deposited To Age E/M Store Yard Of Ge (South Bathinda) Complete All As Specified And Directed By Engr-In- Charge. 223 Supply & Fixing Ceiling Fan Of 1200Mm Sweep Complete With Blades, Down Rods, With And Including Remote Control, Single Phase, 50 Hz, Min Air Delivery 210 Cfm With Service Value 6.00 Bee. Five Star Rated With Brushless Direct Current (Bldc) Motor Connecting Up Complete With And Including Three Core Flexible Pvc Insulated Multi Stranded Copper Conductor Cable Of Suitable Size From Ceiling Rose / Connector, Including Extra Gi / Ms Pipe Down Rod, As Per Site Requirement , With And Including Serial Number Of Fan As Issued By Engineer-In-Charge And Ge Office Name With Red Colour Permaent Marker Complete All As Specified And Directed By Engineer-In-Charge. 224 Dismantling And Taking Down Of Existing Energy Meter And Refixing The Same Complete All As Specified And Directed By Engineer-In- Charge, 225 Dismantling And Taking Down Existing Geyser And Deposit In The Safe Custody / Store Yard Of Age E/M Of Ge (S) Bathinda And Refixing The Same After Carring Out Repair Work/ Rewiring Accn )Complete All As Specified And Directed By Engineer-In- Charge,
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 4
42.
Defence #11192596 AOC
Tender For Provn Of Central Mi Room At Nimu; 1 Lump sum price worked out by the contractor for BUILDING WORKSas listed in Schedule ‘A’ Part-I representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES B/F from Sl page No. 43 2 Lump sum price worked out by the contractor for (SITE CLEARANCE, EXCAVATION & EARTH WORK)as listed in Schedule ‘A’ Part-II representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES B/F from Sl page No. 44 3 Lump sum price worked out by the contractor for (INTERNAL ELECTRIFICATION)as listed in Schedule ‘A’ Part-III representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES B/F from Sl page No. 50 4 Lump sum price worked out by the contractor for (INTERNAL WATER SUPPLY)as listed in Schedule ‘A’ Part-IV representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES B/F from Sl page No. 52 5 Lump sum price worked out by the contractor for (ROAD, PATH & HARDSTANDING)as listed in Schedule ‘A’ Part-V representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES B/F from Sl page No. 54 6 Lump sum price worked out by the contractor for (SEWAGE DISPOSAL)as listed in Schedule ‘A’ Part-VI representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES B/F from Sl page No. 55 7 Lump sum price worked out by the contractor for (AREA DRAINAGE)as listed in Schedule ‘A’ Part-VII representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES B/F from Sl page No. 56 8 Lump sum price worked out by the contractor for (SHED FOR DG SET)as listed in Schedule ‘A’ Part-VIII representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES B/F from Sl page No. 58 9 Lump sum price worked out by the contractor for (HOT WATER SUPPLY)as listed in Schedule ‘A’ Part-IX representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES B/F from Sl page No. 59 10 Lump sum price worked out by the contractor for (EXTERNAL ELECTRIFICATION)as listed in Schedule ‘A’ Part-X representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES B/F from Sl page No. 65 11 Lump sum price worked out by the contractor for (EXTERNAL WATER SUPPLY)as listed in Schedule ‘A’ Part-XI representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES B/F from Sl page No. 66 12 SCH A PART - XII (MISC B/R & E/M ITEMS) (REFER BOQ)Note: This schedule is not pre-priced by MES and the rate indicated as Rs 0.00 under Col 5 signifies this fact only 13 INTERNAL ELECTRIFICATIONS&F Double door three phase prewired distribution board vertical DB VTPN 8 way with acrylic door made out of CRCA sheets 1.6 mm thick,phosphatised powder coated with copper Bus Bar 200 Amps, 415 V,IP 43/IK09, Earth Stud, Din Rail, Polymide terminal blocks for incoming and outgoing circuits, inbuilt loose wire box ,ground terminal blocks ,duly prewired with thimbled flame retardant copper conductors and poly layer for protection in and includingMCCB4 pole 63 Amp rating repturing capacity 16 KA.(Note:- Single Phase MCBs are to be measured and paid for seperately) 14 S&F LED building security light, pressure die cast aluminum housing, 20/25 watts capacity, 240V, IP 65 class, with suitable in-built electronic driver complete incld. fixed on a bracket made out of 1.5 mtr long Med grade GI pipe 40 mm dia bend to shape as directed fitted on wall at a height not less than 5 mtr from groundwith MS clamp, nuts and bolts and washers as required at site and incld. connecting luminarie to the nearest ceiling rose/junction box with 1.5 sqmm PVC insulated 3 core wire complete all as directed and specified by Engr-in-Charge.NOTE - Cost of all minor spares and jobs required for fixing of light fixture on wall and for electrical connections are deemed to be included in the quoted rate. 15 S&F new wall mounted fan of approved make and type complete all as specified and as directed. 16 S&F TV Co-axial socket 1 module, complete all as specified and as directed. 17 S&F Single pole and neutral enclosure with a two pin and earth plug and socket complete with one double pole MCB 20 Amps 18 INTERNAL WATER SUPPLYS&F single piece Vitreous china wash down water closet pan Pedestal Pattern white, with seat white closed pattern with flat bottom and cover mild steel chromium plated or aluminized hinging deviced including flushing system , pipe and joint etc and connection to drain, flushing, pipe, anti-syphonage pipe, and fixing arrangements with fixing bolts etc including making good the disturbed portion of floor in cement concrete 1:2:4 type B-0, as in repairs complete all as spd & directed complete all as specified and directed by Engr-in charge.. 19 S&F CP Grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) dia of outlet is 100 mm complete all as specified and directed by Engr-in charge. 20 S&F hand shower (health faucet ) with 8mm dia and 1 meter long CP flexible tube and wall hookcomplete all as specified Make: Cera, Jaquar , Marc & Hindware as per Sample and directed by Engr -in Charge 21 S&F Soap dish (S/S), any type, fixed to plugs with chromium plated brass screws, all as specified and directed by Engr-in charge. 22 ROAD, PATH & HARD STANDINGM&L for wet mix macadam (WMM) for 150mm thick (compacted thickness) laid in two layers of 75mm each grading as per table 400-13 of MoRTH (Ministry of Road Transport & Highways) specification of Road and Bridge works 2013. Manufactured in WMM plant, material comprising of clean, crushed, graded aggregate and granular material premixed with water to a dense mass, spreading with sensor paver and rolling with vibratory roller of capacity 80-100 KN static weight and conslidating required gradient and camber. The finished surface tolerance to be as per table 900-1 of MoRTH specification for road and bridge works 2013 complete all as specified and directed by Engr-in-Charge. 23 M&L for applying thermoplastic paint marking 2.5mm thick centerline ,stop line,dashes,arrows etc and n exc 10cm wide on roads pavements with hot applied thermoplastic road marking paint ofapproved colour confirming to BS 3262-1989 with special applicater machine all as per manufacturers instructionof any colour on road surfaceincluding cleaning with gunny bags removing all loose dirt/dust complete all as specified and directed. 24 M&L for RCC Septic tank designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, RCC M-30 Design Mix in Walls , Base Slab , Baffle walls and Roof Slab including beams etc with Vent shaft , manhole openings with cover connection etc, complete with effective depth of 1.5 meter and overall depth of 3 meter for 100 users. 25 M&L for Soakage wells excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size 3M Dia and 3 M Depth. 26 EXTERNAL ELECTRIC SUPPLYS&F Polycarbonate junction boxes IP 65 protection of size 0.200 x 0.250 x 0.155 m complete with 1 Nos MCB SP 2.5 Amp & 4 way industrial connector including clamp made out of MS flat 30x5mm connection from junction box to street light fitting with three single core PVC insulated, PVC sheathed wire 2.5 Sqmm copper & PVC conduit 20 mm dia complete all as specified and directed by Engr-in-charge. 27 Excavation in trenches by cutting of road crossing/PCC hard standing, under boundary wallfor laying of pipe/cable including making good the existing surface with same finish to match the original finish complete all as specified and directed by Engr-in-charge. 28 S&FHT/LT MS cable route indicator 4 dia fixed with two Nos of nut, bolt and washers and provision of PCC 1 : 4 : 8 type D-2 using 40 mm grade stone aggregate of not less than 0.018 cum in each at base buried under the groundincl necessary earth work complete all as specified and directed by Engr-in-charge. 29 Supply, installation, testing and commissinoning LT panel board suitable for working on 3 phase ,4 wire ,415 volts, AC ,50Hz indoortype, cubicle, floor mounted, free standing, dust and vermin proof, air ventilation factory fabricated made out of 2 mm thick CRCA sheetduly powder coated and shall be CPRI Approved and as approved by GE. The Panel shall have front and rear opening, locking arrangement, cable alleys, bus bar chamber and switch gear compartment, hinged door with rubber gasket, bottom cable entry holes for incoming and out going cables, earthing terminals, affix danger notice plate, glands, AI bus bar duly covered with heat shrink sleeves colour coaded duly fixed onDMC/SMC insulators, housed in a separate bus bar chamber and control wiring with copper conductor cables of adequate size and length, incoming and outgoing MCCBs shall have extended bus bar links and mounted on 50x50x5mm sizeMS angle iron frame duly painted including PCC 1:2:4 Type B1 (using 20 mm graded stone aggregate ) in foundation design subject to approved of AGE (I) Nimu to sent the site requirementcomplete all as specified and directed including comprising of following :- 30 (a) MCCB 400 Amps, FP, 36 KA, 415 volts, 50Hz - 01 No (I/C)(b) MCCB 200 Amps, FP, 25 KA, 415 volts, 50Hz - 02 No ( CHS)(c) MCCB 125 Amps, FP, 16 KA, 415 volts, 50Hz - 04 Nos (APFC, TPN DB -02, Spare )(d) MCB SPN 40 Amps, 10 KA, 220 volts, 50Hz - 03 Nos (Garage,Street light, Spare-1)(e) On load Chengeover 400 Amps 4 pole -01 No (f)Digital voltmeter, with VSS - 01set(g) Digital Ammeter, with CTs & ASS - 01 set(h) LED phase indication lamps RYB - 01 set(j)Single phase Rotary Automatic Light controller Nature switch with voltage range 120-440V,AC,20 Amps,IP-65,50HZ-01 Nos(k) Copper bus bar TPN 600 Amps rating - 01 set 31 Labour for boring underground upto 100 mm bore for road crossing 3 mtr to 10 mtr not exceeding 1.5 mtr in depth for laying of electric cable and GI tubing in soft/loose soil complete all as specified. 32 EXTERNAL WATER SUPPLYM&Lfor cutting existing GI pipes and insertion of new Tee branches of suitable size to take branch connection of 50mm dia PP-R.Note : Suitable size of Tee branch is deemed to be included in the quoted rate. 33 Construction of stone masonary valve pit chamber of size 90cm x 90 cm x 90 cm (internal dimension) including all necessary excavation and earthwork in hard / dense soil and disposal of surplus soil to a distance not exceeding 50 meters & deposting the same as directed includingPCC in foundation of the mixture (1:4:8) D-2 stone masonary in cement motor 1:4 rendering 15mm thick in cement mortar 1:4 internally finished even and fair and pointing flush externally as the work proceeds in the same mortar as of stone masonary including mild steelframe (made out ofangle in 40x40x6mm) MS steel cover 3.15 mm thick with handle and locking arrangement with ginges angle iron flat as requiredat site including painting of all posed MS work with two coat of synthetic enamel paint over a coat of red oxide primer and painting all the steel surfaces embedded in PCC with two coats of black bituminuos paint andall other relevant work complete . 34 M&L for providing tracer/anti freezing cable of capacity 20W/m required to keep the pipe warm upto avoiding freezing all as specified including electrical wiring cable for connection of suitable size 35 (CENTRAL HEATING SYSTEM)Electric Hot Water Generator : Supply, installation, testing and commissioning ofpackage type electric Hot Water generator constructed out of MS sheet having top open-able cover for easy access and removal of heaters. The HWG shall be suitable for indoor mounting. The generator shall be provided with 50mm thick fibre glass insulation 32 kg density finished with 0.8mm / 22G aluminium cladding sheet. The generator shall have electrical capacity of 50 kW. The heater shall be electrical resistance type, copper tube with chromium plating. The generator shall be complete with float valve, pressure gauge with ball valve, master and bank thermostats, etc. The generator shall be suitable for 3 phase, 415+ 10% Volts, 50 Hz. AC supply. The generator shall complete with self-contained incoming isolation, ammeter, voltmeter, contactors for heater banks in three steps complete with manual/auto rotary switches. 36 Notes:- (i) Allneccassary accessories required for the proper fucntioning of Hot Water Genearator are included in price.(ii) The prices should include lifting, shifting and positioning of units at Site.(iii) Hot Water Genearator installation to done as per Manufacturer recommendation with all installation requirements i.e Foundation, Vibration Isolator,Insulationetc as recommended by Manufacturer for the Ambient Temperature of Site. ODU installation is included in ODU price which includes the Civil Struture, Mechanical Structureetc as recommended byManufacturer.(iv) The Contractor/OEM will shall submit the Hot Water Generator capacity/Burner Capacity conforming to relevant IS Code(v) OEM should submit the Installation and Maintenance Schedule/ Manual for the Boiler. 37 GLYCOL CIRCULATION CENTRIFUGAL PUMPS: Supply, Installation, Testing & Commissioning of PN16 ratedAxial Split Coupled Vertical Inline water pump set with CI casing, Bronze Impeller, SS Shaft and externally flushed outside type balanced mechanical seal and non overloading motor, as per specifications and drawings. with Suitable HP, TEFC squirrel cage induction motor with IE3 type class F insulation, Motor shall be rating of IP 55, operating on 415 ±10% volts, 3 phase, 50Hz AC Supply. The external flush line must be used for the purpose of heat dissipation from the mechanical seal.Pumps with performance characteristics as given below:The internal components of pumps including mechanical seal shall be suitable to sustain a fluid temperature of -25 Degree Celcius to 120 Degree Celcius. Vendor shall be provide antivibration arrangement for pumps . 38 The scope also shall include following below mentioned:(i) Electrical by pass starter for pump setas recommended by OEM. (ii) 25 mm thick polyviny nitrile rubber insulation duly cladded between aluminium sheets of 0.5mm thickness and properly clamped to pump.(iii) Pressure gauges 150 mm dia -03 Nos (iv) Mounting frame with antivibration pads (In case pumps are inline, anti vibration system shall be as per Manufacturers recommendation) (v) RCC/Cement concrete foundation for the pump unit. (In case pumps are inline, foundation shall be as per Manufacturers recommendation).Pump capacity are as under:Capacityand pump headnot less than flow 25 USGPM , Head 20 mtr (Refernce Model No. : Armstrong : Series 4300 - 40-150 - 2p - 1.5 kW) each including the Triple duty valve and End Suction guide. 39 EXPANSION TANK and Pressurisation Unit:Supply, Installation, Testing and commissioning of INSULATED PRESSURISED CLOSED WATER EXPANSION TANK suitable for total volume ofGlycol - Water Solution, circuit along with necessary accessories such as along with necessary accessories such as 2 Nos pumps (1working +1standby) with Pressure Transmitter andinterconnecting Pipe & Isolating Valve complete with piping connections, safety relief valve, drain valve, pressure gauge, automatic air purging arrangement, etc.with Pressure Transmitter andinterconnecting Pipe & Isolating Valve complete with piping connections, safety relief valve, drain valve, pressure gauge, automatic air purging arrangement, etc. The tank shall be pre-charged. Expansion tank Shall be with replaceable heavy duty butyl rubber bladder. The tankconnections should be as per OEM recommendationsand 20 mm drain and charging valve connection to facilitate the on site charging of nitrogen in the tank.The tank shall be fitted with lifting rings and a floor mounting skirt for vertical installation. The tank must be constructed in accordance with IS-STANDARD 2825-1969 (withlates Revision)and Rated at PN 16 . The complete system shall be sourced from single manufacturer and supplied and installed with all accessories and safety fixtures required for proper functioning of the complete hydronic system.The tank shall be duly painted in approved colour shall be complete with pressure switches and power distribution and control panelIP55 Control Panel, Pressure Transmitter, interconnecting piping & wiring. (Tank capacity 500 Ltrs). Hot Glycol - Water closed vessel pressurized expansion tank as described above shall be duly Insulated with 50 mm thick PUF/Nitrile Rubber insulating material or Equivalent U valueInsulating Material and cladded with aluminium Sheet (20G). Electrical by pass starter for pump setas recommended by OEM. 40 Expansion Tank of 500 Lts capacity 41 PRESSURIZATION UNIT: for Pump Set -03 Nos with Control Panel and accessories. 42 Make Up TANK: Supply, installation, testing and commissioning of factory made Make up Water Tank, Rectangular/Circular shape, of 4 mm thick MS sheet (IS 2062), of capacity of 550 litres complete with inlet, outlet, overflow, drain pipe of MS and vent with flame arrestor. Tank will be provided with supports made out of minimum 50mm angle iron duly painted, to keep tank base at minimum (1000mm) above FFL. Service platform shall be provided as per recommendations of OEM. The tank shall be provided with remote indication of levels provided level switches for on-off operation of tranfer pump. Extra high level and extra low level alarm shall be provided. Tank and structure shall be painted with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.Make up Water tank as describedabove should beduly Insulated with 50 mm thick PUF/Nitrile Rubber insulating material and cladded with aluminium Sheet (20G). 43 Supply, Installation, Testing and Commissioning ofSteel plate Radiator( Wall Mounted) confirming EN- 442 , working pressurerange from 10-13 bar having workinh temparture of 110°C, complete with top grill side cover as standard along with inlet ,outlet valve, Air purge valve andwith threaded plug, flow regulator as per OEM.The below desired capacity should be calculated at Altitude of 3600 mts above sea level. Capacity calculation sheet to be provided to Engineer in Charge. The below mentioned capacity is at INLET TEMP: 75 Degree Celcius , OUTLET TEMP: 65 Degree Celcius. Referemcwe Model Series. 44 1.5 kW, Type: 33- DKEK, Length is 1000 mm and Height is 600 mm of Radiator. 45 2.5 kW, Type: 33- DKEK, Length is 1000 mm and Height is 600 mm of Radiator. 46 3.5 kW,Type: 33- DKEK, Length is 1600 mm and Height is 600 mm of Radiator. 47 5 kW,Type: 33- DKEK, Length is 1600 mm and Height is 900 mm of Radiator. 48 5 kW,Type: 33- DKEK, Length is 2000 mm and Height is 600 mm of Radiator 49 M & L for Pre-insulated MS pipe,Class C havingminimum thicknes of PUF insulation as mentioned below and of density 36 Kg/Cum and 26 gauge AL cladding complete suitable for above ground as per sizes shown.The pipes should be insulated with closed cell puf of density 36±2 Kg/Cum of below mentioned thickness. The Pipe should be workable in the temp. range of-50 Degree Celciusto120 Degreec Celcius. Note:-The Pipes size 150mm & below shall be M.S. ‘C’ class as per IS : 1239 50 80 mm with 36 mm PUF thicknes and 26 Gauge Al Cladding. 51 65 mm with 36 mm PUF thicknes and 26 Gauge Al Cladding. 52 50 mm with 36 mm PUF thicknes and 26 Gauge Al Cladding. 53 40 mm with 36 mm PUF thicknes and 26 Gauge Al Cladding. 54 20 mm with 36 mm PUF thicknes and 26 Gauge Al Cladding. 55 Buried under ground/Exposed to Ambient:80 mm with 50 mm PUF thicknes and HDPE Cladding, 26 Gauge Al Cladding. 56 Cabel Tray :-Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling/Ground/wall with M.S. suspenders as per IS code including bolts & nuts, painting suspenders etc. as required of size 150 mm width X 50 mm depth X 1.6 mm thickness 57 Supplying, fixing, testing and commissioning of following diameter valves (PN-16 Rating) (Complete with Flanges integral or welded, fittings, Nuts, Bolts & Gaskets (PN-16 Rating), strainers (Complete with flanges integral or welded, fittings, Nuts, Bolts & Gaskets (PN-16 Rating), gauges etc for condenser water circulation as per specifications. Insulation thickness ofvalves should be equal to the Insulation of PUF and GI Cladding of Pipe Section as specified. Butterfly Valve ( Insulated Valves) with CI body SS disc nitrile sheet & O ring, Complete with fittings, Nuts, Bolts & Gaskets.Butterfly Valve ( Insulated Valves) with CI body SS disc nitrile sheet & O ring, Complete with fittings, Nuts, Bolts & Gaskets. 58 80 mm dia Butterfly Valve 59 65 mm dia Butterfly Valve 60 50 mm dia Butterfly Valve 61 Supplying, fixing, testing and commissioning of Y-STRAINER (Insulated Valves) of Ductile CI Body flanged ends with stainless steel strainer forhot water circulation including Insulation thickness ofvalves should be equal to the Insulation of PUF and GI Cladding of Pipe Section as specified of size 50 mm dia Y strainer. 62 Supplying, fixing, testing and commissioning of NON - RETURN VALVE (Insulated Valves) with duel plate of CI body SS plates vulcanized NBR seal flanged end & PN 16 pressure rating forhot water circulation includingInsulation thickness ofvalves should be equal to the Insulation of PUF and GI Cladding of Pipe Section as sepcified of size 50 mm dia NRV. 63 Supplying, fixing, testing and commissioning of Automatic Air Purge Valves forhot water circulation headeras specified of size Automtic Air Purge Valve 20 mm dia. 64 Supplying, fixing, testing and commissioning of Air Separator compleate allas specified of size 50 mm dia. 65 Supplying, fixing, testing and commissioning of water pressure gauge (100 mm dia) bourdon type with brass ball valve of 3/8 dia and SS tubing, socket.Range (0-50) / (0-100) as required by Engineer In Charge. 66 Supplying, fixing, testing and commissioning of Mercury in glass industrial thermometer in SS-304 casing with 0.5 C least count, range 0-50 C. Brass oil filled thermowell of 1/2 size as required by Engineer In Charge. 67 Electrical distribution Panel Supply, installation, commissioning and testing of factory made, CHS Plant, indoor type made out of CRCA sheet 2 mm thick, frame factory fabricated with front and back openable double door with locking arrangement, with MS angle section 50x50x6 mm support, duly powder coated painting having thickness not less than 100 microns provided suitable gasket to make it dust and vermin proof, suitable for 3 Phase4 wire, 415 Volts, 50 Hz, AC supply system, floor mounted and grounting the legs of panel in PCC foundation 1:4:8 complete as all directed suitable for and including the following :- 68 INCOMERS(i) Bus Bar TPN Al extensible type main bus bars of minimum of 600 A capacity (As per capacity of corresponding incoming / Bus couplers) , and auxilliary bus bars ofsuitable capacity with heat shrunk coloured sleeves and i/c SMC bus bars supports at required intervals complete for cross section, size supports & their spacing etc. for withstanding fault level of50kA .(ii)MCCB 400 Amps, 415 Volt, 36 KA, 4 Pole,Microprocessor release- 01 No for incoming (Extended Rotary Operating Handle, Phase Spreader links and Phase barriers ) Make: Legrand/Schenider/SimensOUTGOINGS(i) 3Nos- 125A ,25 KA TPNMCCB/ACBwith Microprocessor release (3# Hot Water Generator)(ii) MCB 10 Amp,TPN,10KA, C curve - 06, 3 Nos for Pumps , 2 Nos for Pumps ,01 Nos for glycol transfer pump(iii) LED Phase indication lamps (01 Set) with 2Amp back up MCB,Breaker ON/OFF indicating light with 2A MCB, test terminal block set, circuits as per standard practice, auxiliary contacts for positive interlocking of the breakers as required. - 2 Set (iv) Digital Ammeter with in built ASS,metering C.T.sCAST RESIN type, 15VA, and accuracy class-1of 800/5A for measuring current in each phase - 01 Set.(v) All accessories prewired with appropriate size copper strip or wire and thimbles etc. all as required including foundations as per Manufacturers recommendations all as directed by Engnr-in-Charge.Note : Contractor will submit the drawing for approval of panel to GE before execution. 69 LT CABLES : Supply & Laying/ fixing of following size XLPE insulated and PVC sheathed AI conductor armoured cable/unarmoured as required of 1.1 KV grade complete as require (ISI Marked) (in ground/in pipe/in duct/on surface/on cable tray)Note for 49.01 to 49.04 :- Cable shal withstand temperature variation (-) 35 °C to (+) 35 °C at appx 3500 mtr above sea level. 70 3.5 Core x 70 sq.mm. (Electric Hot Water Generator) 71 4.0 Core x 10 sq.mm. (Pump) and (Pressurization Unit) 72 2 Core x 10 sq.mm. (Pump) 73 2 Core x 6 sq.mm (Pressurization Unit) 74 Earthing complete with Copperearth plate electrode of size 60cm X 60cm X 6mm buried directly in ground vertically at a depth not less than 2.25 metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level surrounded from all sides by 15 cm thick and packed layer of charcoal dust and common salt filling in alternate layers etc and connected to and including Copper strip of size 32x6 mm up to 7.5 mtr by means of bolts, nuts, check nuts and washers made of brass and protected by light grade 40mm dia upto 7.5 mtr long GI pipe connected to main controlboard and GI pipe light grade 20mm bore for watering and including funnel, wire mesh, RCC pit cover 50mm thick and PCC chamber pit with PCC 1:2:4 type C2 (including excavation and earth work disposal of surplus soil to a distance not exceeding 50 metre) and testing making test point and testing after completion all as specified and shown on plate No 3 of SSR Part-I 2009 complete all as specified & directed by Engr-in-charge 75 S&F rubber matting conforming to IS-15652-2006 complete as required. of size2m x 1m x 25 mm 76 Glycol - Water SolutionSupplying of Ethylene glycol concentrate along with the necessary additives and inhibitor in cognition in sealed barrels complete all as directed.NOTE;- (i) The glycol concentrate shall be mixed with potable water supplied by contractor and filled in central heating system pipe line after proper leak test of entire circuit. The glycol water mixture ratio shall be 45 : 55 and freezing temperature shall be - 45 Degree Celcius (ii) First charge of glycol is included in the quoted rate. First Charge Include Charge in CHS pipe lineStorage Tank. (Glycol 45 % ,Water 55 %) 77 For CHS 78 Supply of Gycol for running of Plant for 12 months 79 GLYCOL CIRCULATING PUMP: Supply, Erection, Testing and Commissioning ofTransfer pumps for the capacity of 5 LPM 5 meter head for Glycol Fluidtransfer with base frame foundation, bolts coupling coupling guard,TEFC, (OEM design HP for the required Flowand Head ) andother accessories for proper function of the pump. 80 OXYGEN GAS MANIFOLD : Supply , installation , testing and commission 4+4 oxygen manifold with middle frame, tail pipe, NRV and ESSAB make 10x14 regulator complete all as specified and directed by Engr in charge . 81 Supply, installation , testing and commission 3 cylinder emergency inlet for oxygen complete all as specified and directed by Engr in charge . 82 Supply , installation , testing and commission automatic control panel with Analog Display 02 for oxygen complete all as specified and directed by Engr in charge. 83 S&F of copper tubing of size 15 mm OD, EN -13348 Grade , 0.9 mm wall thickness including proper saddling , clamping and insertion of branches connections including all fitting for medical use, complete all as specified and directed by Engr in charge. 84 S&F of copper tubing of size 12 mm OD, EN -13348 Grade , 0.9 mm wall thickness including proper saddling , clamping and insertion of branches connections including all fitting for medical use, complete all as specified and directed by Engr in charge. 85 S&F BS type gas outle with probe for oxygen for medical compleate all as specified and directed by Engr in charge 86 S&F 1/2 Brass ball valve with end fittings including all fittings for medical usecomplete all as specified and directed by Engr in charge. 87 S&F BPC flow meter (0-15 LPM) including humidfire bottle complete all as specified and directed by Engr in charge . 88 S&F 3/8 Brass ball valveincluding all fittings for complete all as specified and directed by Engr in charge. 89 STAND BY DG SET : Supply,install, test and commissioning of silent Diesel Engine Generating set 415 volts, 3 phase, 4 wireengine as per IS08528 conforming to CPCB Norms IV, and alternator as per IS08528 of capacity 400 KVA at NTP with control panel having meters, sound proof canopy etc with foundation (As per OEM design) including all accessories as per manufactures standard and as per the details given below and independent relay panel for automatic on mains failure:- AC Generator should be suitable for ambient conditions at nimu Leh area. 90 (A) Alternator : Standard design alternator rated at 400 KVA (320KW)net output at power factor 0.8, AC, 3 phase 4 wire, 415 V, 50 Cycles/Second, 1500 RPM self excited, self regulated, screen protected, drip proof IP 23 enclosure, brush less design, voltage regulation ± 2.5 % rated voltage from no load to full load and frequency regulation within ± 1.5 % tolerence. (B)DIESEL ENGINE : Vertical diesel engine of suitable capacity, closed circuit as per BS-649 or IS-1002 direct injection type, Electric starting system having rated speed 1500 RPM. The DG set Shall be capable for running with 10% over loading for 01 hour in every 12 hours as perBS-5514/BS-649. Engine shall be multi cylinder, multi stroke, direct injection andequipped with all standard fitting as per manufactures recommendations and mounted on common base frame with following Specifications.(a) Fly wheel with housing (i) Common base frame of sturdy design suitable for anti vibration mounting and permanent concrete foundation for mounting engine and alternator as per manufacturers instructions (b) Cooling system (i) Radiator with fan & belts & guard, rubber hoses and thermostat. (ii) Cooling water pump centrifugal type . 91 (c) GOVERNER : Electronic Governer (d) ELECTRIC STARTING SYSTEM : Electric Self starter , 24 volts DC(12 volt, 150 AH battery 2 Nos)charging alternatoraspermanufacturers design,copper leads with lugs of adequate size complete with initial charging of maintenance free battery 2X12 volt 150 AH capacity. (e) GENERATOR MONITORING PANEL : Comprising of following :- (i) Microprocessor based genset controller for metering, monitoring, governing and protection. (ii) Engine protection for low lub oil pressure, high coolant temperature (alarm & shutdown) (iii) Alternator protection parameters like under voltage, over current, under frequency, over frequency (alarm & shut down) (f) ACCESSORIES:AVM Pads built or separately mounted to manufacturer base frames. (g) COUPLING ARRANGEMENTS: Fixed coupling, flywheel to suit fixed coupling and fly wheel housing.(h) EXHAUST SYSTEM : should have equipped with emission control device as per latest Govt norms. Silencer complete with exhaust pipe of suitable size upto and out side the building all covered with asbestos rope of suitable size all as specified and as directed.(j) FUEL TANK: Daily service fuel tank of capacity suitable for 8 hours continuous operation made out of 3 mm thick (heat retardant) sheet with indicating gauge, built inside the acoustic enclosures or as per manufacturers design 92 (C)ACOUSTIC ENCLOSURE : All as per CPCB norms IV and OEM of DG Sets design.(D)AMF Panel : Supply, install, testing and commissioning of AMF Panel outdoor type, cubical body,dust and vermin proofmade up of CRCA sheet painted with two coats of synthetic enamelled paint over a coat of red oxide primer confirming to IP 45 with front and rear opening with louvers andmounted on floor with PCC pedestal pillars with a clearance of atleast 0.3 m above ground level with glands sockets etc with provision of cable entry from bottom all pre wired and connected complete with following accessories:-(i) Microprocessor based Panel -01 No(ii) Power Contactor heavy duty suitable for generator and mains (iii) Over load relay for genset (iv) Suitable rating isolating switch MCCB for both DG & main supply.(v) Multi functioning meter to indicate voltage, current, frequency, P F, KW & KWH etc (vi) Emergency stop push button.(vii)Set of indicaters : - (a)Low lube oil pressure (b) DG Set over load(viii) Push button to start, stop (ix) Mode selector switch i.e Auto/Manual/Test/ OFF.(x) Set of Instrument fuse (xi)Set of aluminium bus bar of 600 Amps capacity 3 ph, 4 Wire system (xii) Automatic battery charging unit with DC voltmeter, Ammeter and selector switch for trickle/ Boost charging.(xiii) By Pass arrangement of main supply when AMF circuit fail due to any fault with provision of suitable rating change overs and switches. 93 The following items are deemed to be included in the rate quoted for all DG sets:- (i) DHPP for testing purpose shall be supplied by the contractor without any extra cost to Department. (ii)The contractor shall arrange for artificial load (water load/Electrical load) for testing for final testing of DG Set at site and the cost is deemed to be including in above offer. (iii) Testing of sound level should carried out at the site in presence of Engineer-in-Charge(iv) One set of latest Spare part catalogue with price, exploded view of parts and users manual are deemed to be included in the quoted rate.(v) All civil works including foundation for DGSet as per manufacturers drawing/ specification, foundation for AMF panel shall deemed to be included in the quoted rate.(vi) The rate quoted is deemed to be included for initial filling of radiator coolant and lubricating oil upto level.
Contract Date: May 29, 2026 Contract Value : 5.74 Crore
Statutory Bodies & Commissions/Committees No of Bidders 3
43.
Educational and Research Institute #11191898 Price Bid
Tender for Civil Work , 2.1.1 Earth Work In Surface Excavation Not Exceeding 30 Cm In Depth But Exceeding 1.5M In Width As Well As 10 Sqm On Plan Including Disposal Of Excavated Earth Up To 50 M And Lift Up To 1.5 M, Disposed Soil To Be Levelled And Neatly Dressed:All Kinds Of Soil , 2.8.1 Earth Work In Excavation By Mechanical Means (Hydraulic Excavator) /Manual Means In Foundation Trenches Or Drains (Not Exceeding 1.5 M In Width Or 10 Sqm On Plan), Including Dressing Of Sides And Ramming Of Bottoms, Lift Up To 1.5 M, Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soil As Directed, Within A Lead Of 50 M.All Kinds Of Soil , 4.1.8 Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level:1:4:8 (1 Cement : 4 Coarse Sand (Zone-Iii) Derived From Natural Sources : 8 Graded Stone Aggregate 40 Mm Nominal Size Derived From Natural Sources) , 60.7.1 Dry Rubble Masonry _ Dry Rubble Without Concrete Levelling Course Masonry With Good Quality Blasted Rubble Including Packing To Compactness To Lines And Levels Cost And Conveyance Of All Materials Labour Charges Etc. Complete As Per Direction Of Departmental Officers At Site Ne , 2.25 Filling Available Excavated Earth (Excluding Rock) In Trenches, Plinth, Sides Of Foundation Etc. In Layers Not Exceeding 20 Cm In Depth, Consolidating Each Deposited Layer By Ramming And Watering, Lead Up To 50 M And Lift Up To 1.5 M. , 5.1.2 Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement - All Work Up To Plinth Level:1:1:5:3 (1 Cement 1.5 Coarse Sand :3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources) , 5.9.1 Centering And Shuttering Including Strutting, Etc. And Removal Of Form For:Foundations, Footings, Bases Of Columns, Etc For Mass Concrete , 5.9.5 Centering And Shuttering Including Strutting, Etc. And Removal Of Form For:Lintels, Beams, Plinth Beams, Girders Bressumers And Cantilevers , 5.9.6 Centering And Shuttering Including Strutting, Etc. And Removal Of Form For:Columns, Pillars, Piers, Abutments, Posts And Struts , 5.9.3 Centering And Shuttering Including Strutting, Etc. And Removal Of Form For:Suspended Floors, Roofs, Landings, Balconies And Access Platform , 5.9.7 Centering And Shuttering Including Strutting, Etc. And Removal Of Form For:Stairs, (Excluding Landings ) Except Spiral - Staircases) , 5.22.6 Steel Reinforcement For Reinforced Cement Concrete Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Upto Plinth Levelthermo - Mechanically Treated Bars Of Grade Fe-500D Or Moree , 5.2.2 Reinforced Cement Concrete Work In Walls (Any Thickness), Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc. Up Tot Floor Five Level Excluding Cost Of Centering, Shuttering, Finishing And Reinforcement :1:1.5:3( 1 Cement : 1.5 Coarse Sand : 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources) , 5.3 Reinforced Cement Concrete Work In Beams, Suspended Floors, Roofs, Having Slope Up To 15° Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Window Sills, Staircases And Spiral Stair Cases Up To Floor Five Level Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement, With1:1.5:3 (1 Cement : 1.5 Coarse Sand (Zone Iii) Derived From Natural Sources: 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources). , 5.9.16.1 Centering And Shuttering Including Strutting, Etc. And Removal Of Form For: Edges Of Slabs And Breaks In Floors And Wallsunder 20 Cm Wide , 50.6.1.8 Solid Block Masonry Using Pre Cast Solid Blocks (Factory Made) Of Size 40X20x15cm Or Nearest Available Size Confirming To Is 2185 Part I Of 1979 For Super Structure Up To Floor Two Level With Thickness 15Cm In: Cm 1:6 ( 1 Cement : 6 Coarse Sand Etc Complete , 22.5 Providing And Laying Water Proofing Treatment In Sunken Portion Of Wcs, Bathroom Etc., By Applying Cement Slurry Mixed With Water Proofing Cement Compound Consisting Of Applying : A) First Layer Of Slurry Of Cement @ 0.488 Kg/Sqm Mixed With Water Proofing Cement Compound @ 0.253 Kg/Sqm. This Layer Will Be Allowed To Air Cure For 4 Hours. B) Second Layer Of Slurry Of Cement @ 0.242 Kg /Sqm Mixed With Water Proofing Cement Compound @ 0.126 Kg/ Sqm. This Layer Will Be Allowed To Air Cure For 4 Hours Followed With Water Curing For 48 Hours. The Rate Includes Preparation Of Surface, Treatment And Sealing Of All Joints, Corners, Junctions Of Pipes And Masonry With Polymer Mixed Slurry. , 13.1.1 12 Mm Cement Plaster Of Mix:1:4 ( 1 Cement : 4 Fine Sand) , 50.13.1 9 Mm Cement Plastering Of Mix : 1:3 (1 Cement : 3 Fine Sand ) Including All Cost Of Materials, Labour Charges Etc Complete , 9.48.1 Providing And Fixing M.S. Grills Of Required Pattern In Frames Of Windows Etc. With M.S. Flats, Square Or Round Bars Etc. Including Priming Coat With Approved Steel Primer All Complete.Fixed To Steel Windows By Welding , 11.49.2 Providing And Laying Vitrified Tiles In Floor With Different Sizes (Thickness To Be Specified By The Manufacturer), With Water Absorption Less Than 0.08% And Conforming To Is : 15622, Of Approved Brand & Manufacturer, In All Colours And Shade, Laid With Cement Based High Polymer Modified Quick Set Tile Adhesive (Water Based) Conforming To Is : 15477, In Average 6 Mm Thickness, Including Grouting Of Joints (Payment For Grouting Of Joints To Be Made Separately).Size Of Tiles 600X600 Mm , 11.46.2 Providing And Laying Vitrified Tiles Indifferent Sizes (Thickness To Be Specified By Manufacturer), With Water Absorption Less Than 0.08 % And Conforming To I.S. 15622, Of Approved Make, In All Colours & Shade, In Skirting, Riser Of Steps, Over 12 Mm Thick Bed Of Cement Mortar 1:3 (1 Cement : 3 Coarse Sand), Including Grouting The Joint With White Cement & Matching Pigments Etc. Complete.Size Of Tile 600X600 Mm , 8.31 Providing And Fixing Ist Quality Ceramic Glazed Wall Tiles Conforming To Is: 15622 (Thickness To Be Specified By The Manufacturer), Of Approved Make, In All Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Engineer-In Charge, In Skirting, Risers Of Steps And Dados, Over 12 Mm Thick Bed Of Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) And Jointing With Grey Cement Slurry @ 3.3Kg Per Sqm, Including Pointing In White Cement Mixed With Pigment Of Matching Shade Complete. , 11.20.1 Chequerred Precast Cement Concrete Tiles 22 Mm Thick In Footpath & Courtyard, Jointed With Neat Cement Slurry Mixed With Pigment To Match The Shade Of Tiles, Including Rubbing And Cleaning Etc. Complete On 20 Mm Thick Bed Of Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand).Light Shade Pigment Using White Cement , 10.28 Providing And Fixing Stainless Steel (Grade 304) Railing Made Of Hollow Tubes, Channels, Plates Etc., Including Welding, Grinding, Buffing, Polishing And Making Curvature (Wherever Required) And Fitting The Same With Necessary Stainless Steel Nuts And Bolts Complete, I/C Fixing The Railing With Necessary Accessories & Stainless Steel Dash Fasteners, Stainless Steel Bolts Etc., Of Required Size On The Top Of The Floor Or The Side Of Waist Slab With Suitable Arrangement As Per Approval Of Engineer-In-Charge, (For Payment Purpose Only Weight Of Stainless Steel Members Shall Be Considered Excluding Fixing Accessories Such As Nuts, Bolts, Fasteners Etc.) , 5.30 Add For Plaster Drip Course / Groove In Plastered Surface Or Moulding To Reinforced Cement Concrete Projections. , 21.1.1.2 Providing And Fixing Aluminium Work For Doors, Windows, Ventilators And Partitions With Extruded Built Up Standard Tubular Sections/ Appropriate Z Sections And Other Sections Of Approved Make Conforming To Is : 733 And Is: 1285, Fixing With Dash Fasteners Of Required Dia And Size, Including Necessary Filling Up The Gaps At Junctions, I.E. At Top, Bottom And Sides With Required Epdm Rubber/ Neoprene Gasket Etc. Aluminium Sections Shall Be Smooth, Rust Free, Straight, Mitred And Jointed Mechanically Wherever Required Including Cleat Angle, Aluminnium Snap Beading For Glazing /Paneling, C.P. Brass/ Stainless Steel Screws, All Complete As Per Architectural Drawings And The Directions Of Engineer-In-Charge.(Glazing, Paneling And Dash Fasteners To Be Paid For Separately): For Fixed Portionpowder Coated Aluminium (Minimum Thickness Of Powder Coating 50 Micron) , 21.1.2.2 For Shutters Of Doors, Windows & Ventilators Including Providing And Fixing Hinges / Pivots And Making Provision For Fixing Of Fittings Wherever Required Including The Cost Of Epdm Rubber/ Neoprene Gasket Required (Fittings Shall Be Paid For Separately)Powder Coated Aluminium (Minimum Thickness Of Powder Coating 50 Micron) , 21.2.2 Providing And Fixing 12 Mm Thick Prelaminated Particle Board Flat Pressed Three Layer Or Graded Wood Particle Board Conforming To Is : 12823 Grade I Type Ii, In Panelling Fixed In Aluminum Doors, Windows Shutters And Partition Frames With C.P. Brass / Stainless Steel Screws Etc. Complete As Per Architectural Drawings And Directions Of Engineer - In- Charge.Pre- Laminated Particle Board With Decorative Lamination On Both Sides , 21.3.1 Providing And Fixing Glazing In Aluminium Door, Window, Ventilator Shutters And Partitions Etc. With Epdm Rubber / Neoprene Gasket Etc. Complete As Per The Architectural Drawings And The Directions Of Engineer - In -Charge. ( Cost Of Aluminium Snap Beading Shall Be Paid In Basic Item):With Float Glass Panes Of 4.0 Mm Thickness (Weight Not Less Than 10Kg/Sqm) , 9.117.1 Providing And Fixing Factory Made Upvc Door Frame Made Of Upvc Extruded Sections Having An Overall Dimension As Below (Tolerance ±1 Mm), With Wall Thickness 2.0Mm (±0.2 Mm), Corners Of The Door Frame To Be Jointed With Galvanized Brackets And Stainless Steel Screws, Joints Mitred And Plastic Welded. The Hinge Side Vertical Of The Frames Reinforced By Galvanized M.S. Tube Of Size 19 X 19 Mm And 1 Mm (± 0.1 Mm) Wall Thickness And 3 Nos. Stainless Steel Hinges Fixed To The Frame Complete As Per Manufacturers Specification And Direction Of Engineer-In-Chargeextruded Section Profile Size 48X40 Mm , 9.118.2 Providing And Fixing To Existing Door Frames30 Mm Thick Factory Made Polyvinyl Chloride (Pvc) Door Shutter Made Of Styles And Rails Of A Upvc Hollow Section Of Size 60X30 Mm And Wall Thickness 2 Mm (± 0.2 Mm), With Inbuilt Decorative Moulding Edging On One Side. The Styles And Rails Mitred And Joint At The Corners By Means Of M.S. Galvanised/Plastic Brackets Of Size 75X220 Mm Having Wall Thickness 1.0 Mm And Stainless Steel Screws. The Styles Of The Shutter Reinforced By Inserting Galvanised M.S. Tube Of Size 25X20 Mm And 1 Mm (± 0.1 Mm) Wall Thickness. The Lock Rail Made Up Of H Section, A Upvc Hollow Section Of Size 100X30 Mm And 2 Mm (± 0.2 Mm) Wall Thickness Fixed To The Shutter Styles By Means Of Plastic/Galvanised M.S. U Cleats. The Shutter Frame Filled With A Upvc Multi-Chambered Single Panel Of Size Not Less Than 620 Mm, Having Over All Thickness Of 20 Mm And 1 Mm (± 0.1 Mm) Wall Thickness. The Panels Filled Vertically And Tie Bar At Two Places By Inserting Horizontally 6 Mm Galvanised M.S. Rod And Fastened With Nuts And Washers, Complete As Per Manufacturers Specification And Direction Of Engineer-In-Charge. , 10.5.2 Providing And Fixing 1 Mm Thick M.S. Sheet Door With Frame Of 40X40x6 Mm Angle Iron And 3 Mm M.S. Gusset Plates At The Junctions And Corners, All Necessary Fittings Complete, Including Applying A Priming Coat Of Approved Steel Primer.Using Flats 30X6 Mm For Diagonal Braces And Central Cross Piece , 22.23.2 Providing And Applying Integral Crystalline Slurry Of Hydrophilic In Nature For Waterproofing Treatment To The Reinforced Cement Concrete Structures Like Retaining Walls Of The Basement, Water Tanks, Roof Slabs, Podiums, Reservior, Sewage & Water Treatment Plant, Tunnels / Subway And Bridge Deck Etc., Prepared By Mixing In The Ratio Of 5 : 2 (5 Parts Integral Crystalline Slurry : 2 Parts Water) For Vertical Surfaces And 3 : 1 (3 Parts Integral Crystalline Slurry : 1 Part Water) For Horizontal Surfaces And Applying The Same From Negative (Internal) Side With The Help Of Synthetic Fiber Brush. The Material Shall Meet The Requirements As Specified In Aci-212-3R-2010 I.E By Reducing Permeability Of Concrete By More Than 90% Compared With Control Concrete As Per Din 1048 And Resistant To 16 Bar Hydrostatic Pressure On Negative Side. The Crystalline Slurry Shall Be Capable Of Self-Healing Of Cracks Up To A Width Of 0.50Mm. The Work Shall Be Carried Out All Complete As Per Specification And The Direction Of The Engineerin Charge. The Product Performance Shall Carry Guarantee For 10 Years Against Any Leakage.For Horizontal Surface One Coat @1.10 Kg Per Sqm. , 13.26 Providing And Applying Plaster Of Paris Putty Of 2 Mm Thickness Over Plastered Surface To Prepare The Surface Even And Smooth Complete , 13.48.1 Finishing With Deluxe Multi Surface Paint System For Interiors And Exteriors Using Primer As Per Manufacturers Specifications:Two Or More Coats Applied On Walls @ 1.25 Ltr/10 Sqm Over And Including One Coat Of Special Primer Applied @ 0.75 Ltr /10 Sqm , 13.48.3 Finishing With Deluxe Multi Surface Paint System For Interiors And Exteriors Using Primer As Per Manufacturers Specifications:Painting Steel Work With Deluxe Multi Surface Paint To Give An Even Shade. Two Or More Coat Applied @ 0.90 Ltr/10 Sqm Over An Under Coat Of Primer Applied @ 0.80 Ltr/10 Sqm Of Approved Brand And Manufacture , 16.68 Providing And Laying 60 Mm Thick Factory Made Cement Concrete Interlocking Paver Block Of M - 30 Grade Made By Block Making Machine With Strong Vibratory Compaction, Of Approved Size, Design & Shape, Laid In Required Colour And Pattern Over And Including 50 Mm Thick Compacted Bed Of Coarse Sand, Filling The Joints With Fine Sand Etc. All Complete As Per The Direction Of Engineer-In-Charge. , Od398633/2025-2026 Supplying And Fixing Steel Pressed Single Panelled Door Of Size 120*205Cm With Steel Frames Using Superior Quality Gi Sections Made Of Tata Steel , Od398630/2025-2026 Providing And Fixing Roller Blinds Curtains Using Good Quality Materials, Fitted To The Wall With Necessary Fittings. All Complete As Per Direction Of Engineer In-Charge , Od398632/2025-2026 Providing And Fixing Of Acrylic Name Board With Printed Acrylic Board .All Work As Per The Direction Of Engineer In Charge , Od398631/2025-2026 Supply And Fixing Of Name Board Of Size 3.60*0.60M Made Of Acp Panels Supported Over Gi Frame Work , Furnishing Work , Od398627/2025-2026 Providing And Fixing Staff Table Of Size 2.00X0.70X0.75M Made With Marine Plywood 18Mm Thick Over Fixing 3Mm Thick Teakwood Veneer, 1Mm Thick Mica Lamination On Inside And Providing One Draw ,One Cupboard,Key Board Including All Other Fittings All Cost Of Materials All Labour Charges Etc Complete.. , Od398625/2025-2026 Providing And Fixing Staff Table Of Size 1.80X0.70X0.75M Made With Marine Plywood 18Mm Thick Over Fixing 3Mm Thick Teakwood Veneer, 1Mm Thick Mica Lamination On Inside And Providing One Draw ,One Cupboard,Key Board Including All Other Fittings All Cost Of Materials All Labour Charges Etc Complete. , Od398626/2025-2026 Providing And Supplying Staff Revolving Chair , Od398629/2025-2026 Supplying High Back Executive Chair Nylon Base Multi-Function Mechanism, With Cushion And Leather Finish, Including Transporting Charges And All Other Loading And Handling Charges. , Od398628/2025-2026 Supplying Of Public / Waiting Seating: Three Seater. ( 35 Kg - Gw ) Gauge : 14 &Rdquo;, Dimension: 173Cm * 64Cm * 89Cm. Seat Dimension : 43Cm * 51Cm * 49Cm. Seat &Amp; Back: 1.5Mm Perforated Powder Coated. Beam: 2.0Mm Mild Steel Powder Coated , Od398624/2025-2026 Supply Of Godrej Steel Shelf Of Size 1.00 X 0.50 X2.10M, 16 Gauge , Made Of Good Quality Sheet Applying Suitable Paints All Complete As Per The Direction Of Engineer-In Charge , Plumbing And Sanitary Fittings , 17.3.1 Providing And Fixing White Vitreous China Pedestal Type Water Closet (European Type) With Seat And Lid, 10 Litre Low Level White Vitreous China Flushing Cistern & C.P. Flush Bend With Fittings & C.I. Brackets, 40 Mm Flush Bend, Overflow Arrangement With Specials Of Standard Make And Mosquito Proof Coupling Of Approved Municipal Design Complete, Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls And Floors Wherever Required :W.C. Pan With Isi Marked White Solid Plastic Seat And Lid , 18.48 Providing And Placing On Terrace (At All Floor Levels) Polyethylene Water Storage Tank :Isi 12701 Marked, With Cover And Suitable Locking Arrangement And Making Necessary Holes For Inlet, Outlet And Overflow Pipes But Without Fittings And The Base Support For Tank. , 50.17.1.5 Supplying And Fixing Cp Health Faucet Superior Quality ( Jagur Or Equvalent Make ) Including Cost Of Materials And Labour Charges Etc Complete As Per The Direction Of Site Engineer-In-Charge. , 50.17.1.3 Supplying And Fixing Cp Towel Rod 60Cm Or Nearest Available Length Including Cost Of Materials And Labour Charges Etc Complete As Per The Direction Of Site Engineer-In Charge. , 50.17.1.1 Supplying And Fixing Stainless Steel Soap Dish Including Cost Of Materials And Labour Charges Etc Complete As Per The Direction Of Site Engineer-In-Charge. , 17.7.8 Providing And Fixing Wash Basin With C.I. Brackets, 15 Mm C.P. Brass Pillar Taps, 32 Mm C.P. Brass Waste Of Standard Pattern, Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls Wherever Require:White Vitreous China Surgeon Type Wash Basin Of Size 660X460 Mm With A Pair Of 15 Mm C.P. Brass Pillar Taps With Elbow Including Operated Levers , 50.18.9.9.1 Providing And Fixing Pvc Pipes Includings Jointing Of Pipes With One Step Pvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineer In Charge.110 Mm Dia 6Kgf/Cm2 , 50.18.9.22.4 Providing And Fixing Pvc Moulded Fittings/ Accessories For Rigid Pvc Pipes, Including Jointing With Pvc Solvent Cement- 110 Mm Dia Bend. , 50.18.9.22.5 Providing And Fixing Pvc Moulded Fittings/ Accessories For Rigid Pvc Pipes Including Jointing With Pvc Solvent Cement 110X110x110 Mm Dia Tee , 50.18.9.13.1 Providing And Fixing Pvc Pipes, Fittings Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer-In-Charge 25 Mm Dia 12 Kgf/ Cm2- External Work- Exposed On Wall Dia 10 Kgf/Cm2 - External Work- Exposed On Wall , 50.18.9.14.1 Providing And Fixing Pvc Pipes, Fittings Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer-In-Charge 32 Mml Dia 10 Kgf/Cm2 - External Work- Exposed On Wall , 50.18.9.17.1 Providing And Fixing Pvc Pipes Including Fixing The Pipe With Clamps/ Clip At 1.00 M Spacing . This Includes Jointing Of Pipes With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer-In-Charge 63 Mm Dia 6 Kgf/Cm2 - External Work - Exposed On Wall , 50.18.9.20.4 Providing And Fixing Pvc Moulded Fittings/ Accessories For Rigid Pvc Pipes, Including Jointing With Pvc Solvent Cement - 63 Mm Dia Bendl , 50.18.9.20.5 Providing And Fixing Pvc Moulded Fittings/Accessories For Rigid Pvc Pipes Including Jointing With Pvc Solvent Cement - 63X63x63 Mm Dia Tee , 18.54.4 Providing And Fixing Ptmt Bib Cock Of Approved Quality And Colour.15 Mm Nominal Bore, 90 Mm Long, Weighing Not Less Than 93 Gms , Electrical Works , 90.1.1.1 Supply And Laying Medium Gauge Pvc Conduit Of The Following Sizes Conforming To Is 9537/1983 Part Iii In Roof Slab, Jointing The Pipes With Pvc Solvent Cement, Tying & Fixing The Conduit Firmly With The Re-Inforcement Etc. As Required.20 Mm , 90.2.2.1 Supply And Wiring Points According To Is 732-1989 Through The Existing Conduit With 1.00 Sq Mm Frls Pvc Insulated Stranded Single Core Copper Conductor Cable 650V Grade, Including Providing Switch Board Main And Continuous Earthing With No.14 Swg Bare Copper,Required Quantity Of Copper Earth Socket, Brass Bolt And Nut Crimping/ Soldering Etc Complete With Suitable Size Modular Type Metal Switch Boxes, Modular Type Front Plates (White) Etc. Up To And Including 6A Modular Type Sp Switches And Making Good The Surface Of Wall, Colour Washing Etc. Complete. All The Terminations In The Switch Boards And Dbs Shall Be Tinned And The Wires Shall Be Drawn And Fixed Along The Periphery Of The Box Using Suitable Ties, Tie Mounts Etc As Required. (Group B/ Rohs Compliant Modular Accessories).Single Control Light Point With 6A, Plate Ceiling Rose - Short Point , 1.10.2 Wiring For Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq.Mmfrls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Medium Class Pvc Conduit, With Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm. Frls Pvc Insulated Copper Conductor Single Core Cable Etc As Required.Group B , 90.2.2.3 Supply And Wiring Points According To Is 732-1989 Through The Existing Conduit With 1.00 Sq Mm Frls Pvc Insulated Stranded Single Core Copper Conductor Cable 650V Grade, Including Providing Switch Board Main And Continuous Earthing With No.14 Swg Bare Copper,Required Quantity Of Copper Earth Socket, Brass Bolt And Nut Crimping/ Soldering Etc Complete With Suitable Size Modular Type Metal Switch Boxes, Modular Type Front Plates (White) Etc. Up To And Including 6A Modular Type Sp Switches And Making Good The Surface Of Wall, Colour Washing Etc. Complete. All The Terminations In The Switch Boards And Dbs Shall Be Tinned And The Wires Shall Be Drawn And Fixed Along The Periphery Of The Box Using Suitable Ties, Tie Mounts Etc As Required. (Group B/ Rohs Compliant Modular Accessories).Single Control Light Point Without Ceiling Rose - Short Point , 90.2.2.4 Supply And Wiring Points According To Is 732-1989 Through The Existing Conduit With 1.00 Sq Mm Frls Pvc Insulated Stranded Single Core Copper Conductor Cable 650V Grade, Including Providing Switch Board Main And Continuous Earthing With No.14 Swg Bare Copper,Required Quantity Of Copper Earth Socket, Brass Bolt And Nut Crimping/ Soldering Etc Complete With Suitable Size Modular Type Metal Switch Boxes, Modular Type Front Plates (White) Etc. Up To And Including 6A Modular Type Sp Switches And Making Good The Surface Of Wall, Colour Washing Etc. Complete. All The Terminations In The Switch Boards And Dbs Shall Be Tinned And The Wires Shall Be Drawn And Fixed Along The Periphery Of The Box Using Suitable Ties, Tie Mounts Etc As Required. (Group B/ Rohs Compliant Modular Accessories).Single Control Ceiling Fan Point With 6 A, 3 Plate Ceiling Rose & With Socket Size Stepped Electronic Regulator. - Short Point , 90.2.2.5 Supply And Wiring Points According To Is 732-1989 Through The Existing Conduit With 1.00 Sq Mm Frls Pvc Insulated Stranded Single Core Copper Conductor Cable 650V Grade, Including Providing Switch Board Main And Continuous Earthing With No.14 Swg Bare Copper,Required Quantity Of Copper Earth Socket, Brass Bolt And Nut Crimping/ Soldering Etc Complete With Suitable Size Modular Type Metal Switch Boxes, Modular Type Front Plates (White) Etc. Up To And Including 6A Modular Type Sp Switches And Making Good The Surface Of Wall, Colour Washing Etc. Complete. All The Terminations In The Switch Boards And Dbs Shall Be Tinned And The Wires Shall Be Drawn And Fixed Along The Periphery Of The Box Using Suitable Ties, Tie Mounts Etc As Required. (Group B/ Rohs Compliant Modular Accessories).Call Bell Point With 6 A Bell Push At One End And 6 A, 3 Plate Ceiling Rose At Other End - Short Point , 90.2.2.6 Supply And Wiring Points According To Is 732-1989 Through The Existing Conduit With 1.00 Sq Mm Frls Pvc Insulated Stranded Single Core Copper Conductor Cable 650V Grade, Including Providing Switch Board Main And Continuous Earthing With No.14 Swg Bare Copper,Required Quantity Of Copper Earth Socket, Brass Bolt And Nut Crimping/ Soldering Etc Complete With Suitable Size Modular Type Metal Switch Boxes, Modular Type Front Plates (White) Etc. Up To And Including 6A Modular Type Sp Switches And Making Good The Surface Of Wall, Colour Washing Etc. Complete. All The Terminations In The Switch Boards And Dbs Shall Be Tinned And The Wires Shall Be Drawn And Fixed Along The Periphery Of The Box Using Suitable Ties, Tie Mounts Etc As Required. (Group B/ Rohs Compliant Modular Accessories).Combined Plug Point With 6 A, 5 Pin Plug Socket Controlled By 6 A Switch In The Same Switch Board As That Of Light Points , 90.2.2.7 Supply And Wiring Points According To Is 732-1989 Through The Existing Conduit With 1.00 Sq Mm Frls Pvc Insulated Stranded Single Core Copper Conductor Cable 650V Grade, Including Providing Switch Board Main And Continuous Earthing With No.14 Swg Bare Copper,Required Quantity Of Copper Earth Socket, Brass Bolt And Nut Crimping/ Soldering Etc Complete With Suitable Size Modular Type Metal Switch Boxes, Modular Type Front Plates (White) Etc. Up To And Including 6A Modular Type Sp Switches And Making Good The Surface Of Wall, Colour Washing Etc. Complete. All The Terminations In The Switch Boards And Dbs Shall Be Tinned And The Wires Shall Be Drawn And Fixed Along The Periphery Of The Box Using Suitable Ties, Tie Mounts Etc As Required. (Group B/ Rohs Compliant Modular Accessories).Independent Plug - Short Points , 90.3.18.2 Supply, Fabrication, Conveyance And Fixing The Following Sizes Of B Class Gi Pipe Bent To Shape / Cut And Welded To Shape And Fixing The Same To Wall / Parapet Using Clamps As Noted Along With Each Size, Painting With 2 Coats Of Synthetic Enamel Paint Over A Coat Of Zinc Chromate Primer, Making Good The Damages, Colour Washing Etc As Required.32 Mm Dia With Hg Company Fabricated Clamps , 90.4.5.4 Supply, Installation, Testing And Commissioning Of Ceiling Fan Of Following Sizes Including Wiring The Down Rods Of Standard Length (Up To 30 Cm) With 1.5 Sq. Mm Frls Pvc Insulated, Copper Conductor, Single Core Cable Etc. As Required. 1200Mm Sweep - Ceiling Fan Complete With Service Value Minimum 4.0(Cub Meter/Minute/Watt), Air Delivery Minimum 210(Cubic Meter/Minute), Copper Winding Suitable For 230V/240V Single Phase Ac Supply , 90.5.1.3 Supply And Fixing The Following Types Of Superior Quality 250V A.C Call Bell On Existing M.S. Box And Giving Connections With Required Length Of 3 Core, 16 / 0.20Mm 650/1100V Grade Pvc Insulated And Pvc Sheathed Round Copper Conductor Flex Wire Conforming To Relevant Iss Or With The Extended Original Wiring, Earthing The Ms Box And Making Good The Surface As Required.Ding Dong Bell , 90.6.10.1 Supply And Fixing Of Following Sizes Of Light Gauge Pvc Conduit Along With Accessories In Surface/ Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required20 Mm , 90.10.3.15 Supply And Fixing The Following Modular Switches & Accessories In The Existing Front Plates And Giving Necessary Connections As Required (Rohs Compliant )32A Dp Switch With Indicator) , 90.10.3.14 Supply And Fixing The Following Modular Switches & Accessories In The Existing Front Plates And Giving Necessary Connections As Required (Rohs Compliant )25A Sp Switch With Indicator , 90.10.3.32 Supply And Fixing The Following Modular Switches & Accessories In The Existing Front Plates And Giving Necessary Connections As Required (Rohs Compliant )25A 3 Pin Plug Top With Indicator , 90.10.3.33 Supply And Fixing The Following Modular Switches & Accessories In The Existing Front Plates And Giving Necessary Connections As Required (Rohs Compliant )25A 3Pin Shuttered Socket , 90.15.4.2 Supply Conveyance, Installation, Testing And Commissioning Of 36/40W Led Street Light Output Greater Than 105Lumen/W 4000-6000 K With Ip 66 Protection Led Chip Make Cree/Lumilled/Nichea With Power Factor Greater Than 0.95 At Full Load, Internal Surge Protection Up To 8 Kv,And Aluminium Pressure Die-Cast Powder Coated Housing,Acrylic Cover Complete With Thd Less Than 10%, Power Factor Greater Than 0.98, Rohs Compliant, Duly Wired Up For Use On 230 V Ac Supply. Driver Compartment Should Be Seperatly Accessible For Maintenance (Lm 79&80 Certificates From Nabl Accredited Third Party Lab To Be Produced Mentioning Chip Manufacturer) , 90.16.1.3 Supply And Drawing Bare Earthing Conductors Of The Following Sizes Along With Wiring/ Cables And Giving Connection As Required3.15 Mm Copper Conductor ( 10 Swg) , 90.16.1.1 Supply And Drawing Bare Earthing Conductors Of The Following Sizes Along With Wiring/ Cables And Giving Connection As Required2.00 Mm Copper Conductor ( 14 Swg) , 90.16.5.3 Supply Of Superior Quality Copper Earth Socket For The Following Size Of Earth Conductor Including Crimping Etc. As Required.3.15 Mm (10 Swg) , 2.3.1 Supplying And Fixing Following Way, Single Pole And Neutral, Sheet Steel, Mcb Distribution Board, 240 Volts, On Surface/ Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Including Earthing Etc. As Required. (But Without Mcb/Rccb/Isolator) 6 Way, Double Door , 2.3.4 Supplying And Fixing Following Way, Single Pole And Neutral, Sheet Steel, Mcb Distribution Board, 240 Volts, On Surface/ Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Including Earthing Etc. As Required. (But Without Mcb/Rccb/Isolator) 16 Way, Double Door , 2.10.1 Supplying And Fixing 5A To 32 A Rating, 240/415 Volts, 10 Ka, C Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. Single Pole , 2.10.3 Supplying And Fixing 5A To 32 A Rating, 240/415 Volts, 10 Ka, C Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. Double Pole , 2.12.1 Supplying And Fixing Following Rating, Double Pole, 240 Volts, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.40 Commissioning Etc. As Required. 40 Amps Amps , 2.14.2 Supplying And Fixing Following Rating, Double Pole, (Single Phase And Neutral),240 Volts, Residual Current Circuit Breaker (Rccb), Having A Sensitivity Current 30 Milli Amperes In The Existing Mcb Db Complete With Connections, Testing And , 1.17.2 Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel/ Pvc Conduit As Required.2 X 1.5 Sq. Mm , 1.17.4 Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel/ Pvc Conduit As Required.4 X 1.5 Sq. Mm , 1.17.11 Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel/ Pvc Conduit As Required.2 X 2.5 Sq. Mm , 1.17.13 Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel/ Pvc Conduit As Required.4 X 2.5 Sq. Mm , 1.17.20 Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel/ Pvc Conduit As Required.2 X 4 Sq. Mm , 1.17.29 Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel/ Pvc Conduit As Required.2 X 6 Sq. Mm , 1.24.3 Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required.15/16 annual periodical maintenance Switch , 1.24.5 Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required.6 Pin 15/16 annual periodical maintenance Socket Outlet , 1.26 Supplying And Fixing Modular Blanking Plate On The Existing Modular Plate & Switch Box Excluding Modular Plate As Required. , 1.27.2 Supplying And Fixing Following Size/ Modules, Gi Box Alongwith Modular Base & Cover Plate For Modular Switches In Recess Etc As Required.3 Module (100Mmx75mm) , 1.56 Supplying And Fixing Suitable Size Gl Box With Modular Plate And Cover In Front On Surface Or In Recess, Including Providng And Fixing 2 Nos. 3 Pin 5/6 A Modular Socket Outlets And 2 Nos. 5/6 A Modular Switches, Connection Etc. As Required. (For Light Plugs To Be Used In Non Residential Buildings). , 1.58 Supplying And Fixing Pvc Batten/ Angle Holder Including Connection Etc. As Required. , Od398610/2025-2026 Supply ,Installation Of 32 A Kit Cat Fuse Unit Made By Porcelain/ Ceramic , Od398618/2025-2026 Providing And Fixing Of Service Pipe (32 Mm) , Od398612/2025-2026 Supply And Fixing 200Mm Plastic Shade On Existing Batten/Angle/Pendant/Bracket Fittings As Required , Od398615/2025-2026 Supply And Fixing 9 W Led Bulb On Existing Lamp Holder B22 , Od398613/2025-2026 Supply And Providing Suitable Iron Hook Grouted On The Ceiling For Hooking The Ceiling Fan , Od398622/2025-2026 Supply, Conveyance, Installation, Testing And Commissioning Of The Following Sizes Of Exhaust Fans In The Existing Opening, Fixing Necessary Bolt And Nuts, Making Good The Damages Etc. As Required Including Giving Connections With Required Length Of 24/0.20Mm Pvc Insulated And Pvc Sheathed 3 Core Round Copper Conductor Flex Wire Conforming To Relevant Iss. -200 Mm, Single Phase Light Duty Exhaust Fan In Plastic Frame ( Light Duty Exhaust Fan) , Od398616/2025-2026 Fabrication, Supply And Installation Of Wall Mounting Powder Coated Open Type Gi Meter Box Of Following Size Suitable For Fixing Single Phase Energy Meter, Kit Cat Fuse, Neutral Link Etc. Hinged Door Construction, Knock Out For Cable Entry Etc. As Required , 90.6.6.2 Supply And Drawing Frls Pvc Insulated & Sheathed 650/1100 V Grade 3 Core Copper Conductor Flat Cable For Submersible Pump Motor Conforming To Is 694 Part I 1990 As Required Including Giving Necessary Connections Of The Following Sizes.2.50 Sq Mm , Od398614/2025-2026 Supply Installation Testing And Commissioning Of Single Phase Dol Starters For 0.25 To 3 Hp Motor , Od398617/2025-2026 Supply Installation Testing And Commissioning Of Water Purifier Wit The Following Specifications (12 L Ro + Uv + Tds + Controller) , Od398619/2025-2026 Supply Installation Testing And Commissioning Of Iso / Bis Certified Igbt Technology Based 2.5Kv Online Ups/Inverter With Minimum 3 Years On-Site Waaranty And Having The Following Minimum Specifications. 1. Output:230V+1% 50Hz Sine Wave Single Phase. 2. Input: 170V To 270V Hz Ac 3. Rating: 2.5Kva, 4. Backup Time: Minimum 2 Hrs, On Full Load, 5. Efficiency: 90% Or Higher. 6. Battery Bank: 150Vah/Above(2Nos) Or Higher Tubular Battery With Minimum 3 Years Warranty With Suitable Battery Rack. 7. Protection: Over Load, Short Circuit, Battery Reverse Polarity, Input Voltage Below Or Above The Specified Range Over Discharge Or Charge Of Battery, Accepted Model: Hykon Or Equivalent Brand With Better Specification. , Od398620/2025-2026 Supply, Conveyance, Installation And Testing Of 80Cm(32 Inch) Hd Ready Led Tv Of The Following Sizesusing Standard Accessories Including And Providing Wall Mounting Stands. Screen Resolution 1366X768- Hd And 2 Hdmi &Amp; 1 Usb Ports, Working On 230V/240V Single Phase A/C As Required , Od398611/2025-2026 Supply And Installation Of Set Top Box , Od398623/2025-2026 Earthing With G.I. Earth Pipe 2.5 Metre Long, 40 Mm Dia Including Accessories, And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Etc. ( But With Charcoal/ Coke And Salt) As Required , Od398621/2025-2026 Supply &Amp; Installation Of 1200Mm, 20W Led Tube And Giving Connections With Required Length Of 16/0.20Mm 3 Core Copper Conductor Flex Wire . , Network Wiring And Installation , 90.6.10.1 Supply And Fixing Of Following Sizes Of Light Gauge Pvc Conduit Along With Accessories In Surface/ Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required20 Mm , 1.27.1 Supplying And Fixing Following Size/ Modules, Gi Box Alongwith Modular Base & Cover Plate For Modular Switches In Recess Etc As Required.1 Or 2 Module (75Mmx75mm) , 1.53.1 Supplying And Drawn Of Utp 4 Pair Cat 6 Lan Cable In The Existing Surface/Recessed Steel/Pvc Conduit As Required1 Run Of Cable , Od398643/2025-2026 Providing And Fixing Of 16-Port Gigabit Unmanaged Switch.( D-Link Dgs-1016A Or Equivalent ) , Od398639/2025-2026 Supply And Fixing/Crimping Modular Cat6 Rj45 Data Socket On The Existing Modular Plate Or Patch Panel.(Rj 45 Data Socket Without Face Plate) , Od398644/2025-2026 Supply Installation Testing And Commissioning Of Following Sizes Of Wall Mount Network Rack. 4U 350D( But Without Server, Switches Cooling Fans Etc.) , Od398636/2025-2026 Supply Installation Testing And Commissioning Of Cat6 Utp 24-Port Network Panel Desktop 19-Inch Rack Integration Server Mounting Shielded.24 Port Laded Patch Panel (D-Link Or Equivalent) As Required. , Od398634/2025-2026 Supply Installation Testing And Commissioning Of Wireless Ac1200, Dual-Band And Ceiling Mount Gigabit Access Point (Tp-Link Eap225 Ac1200 Wireless Mu-Mimo Gigabit Indoor/Outdoor Access Point/ Equivalent) , Od398637/2025-2026 Supply And Stackingg Of Cat-6 Patch Cord -2M , Od398640/2025-2026 Supply And Stacking Of Cat-6 Patch Cord Cable-1Mtr , Od398642/2025-2026 Supply And Stacking Of Cat-6 Patch Cord Cable- 0.5 Mtr , Od398641/2025-2026 Supply, Conveyance, Installation And Testing Of Cooling Fan For Incubator, Fan For Computer Server 120 * 120 * 38Mm, 4.7 Inch Black , Od398638/2025-2026 Supply And Fixing/Crimping Modular Cat6 Rj45 Data Socket On The Existing Modular Plate Or Patch Panel.(Rj 45 Data Socket Without Face Plate) , Od398635/2025-2026 Supply Conveyance And Installation Of Poe Injector. (Tenda Te-Poe30g-At Gigabit Poe Injector Or Equivalent) N
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Contract Date: Ref. Documents Contract Value : 9.24 Lakh
Boards / Undertakings / PSU No of Bidders 4
45.
Rural Development #11187500 AOC
Tender For Mp-Lads-2022-23 Unni Smaraka Vayanasala Kothamukku -Veliyankode Panchayath -General Civil Work- 1 Unni Smaraka Vayanasala 2 2.32:Clearing Grass And Removal Of The Rubbish Up To A Distance Of 50 M Outside The Periphery Of The Area Cleared. 3 15.3:Demolishing R.C.C. Work Manually / By Mechanical Means Including Stacking Of Steel Bars And Disposal Of Unserviceable Material With In 50 Metres Lead As Per Direction Of Engineer -In-Charge. 4 15.7.4:Demolishing Brick Work Manually / By Mechanical Means Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Metres Lead As Per Direction Of Engineer-In-Charge.In Cement Mortar 5 2.8.1:Earth Work In Excavation By Mechanical Means (Hydraulic Excavator) /Manual Means In Foundation Trenches Or Drains (Not Exceeding 1.5 M In Width Or 10 Sqm On Plan), Including Dressing Of Sides And Ramming Of Bottoms, Lift Up To 1.5 M, Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soil As Directed, Within A Lead Of 50 M.All Kinds Of Soil 6 4.1.8:Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level:1:4:8 (1 Cement : 4 Coarse Sand (Zone-Iii) Derived From Natural Sources : 8 Graded Stone Aggregate 40 Mm Nominal Size Derived From Natural Sources) 7 7.1.1:Random Rubble Masonry With Hard Stone In Foundation And Plinth Including Levelling Up With Cement Concrete 1:6:12 (1 Cement : 6 Coarse Sand : 12 Graded Stone Aggregate 20 Mm Nominal Size) Up To Plinth Level With:Cement Mortar 1:6 (1 Cement : 6 Coarse Sand) 8 2.25:Filling Available Excavated Earth (Excluding Rock) In Trenches, Plinth, Sides Of Foundation Etc. In Layers Not Exceeding 20 Cm In Depth, Consolidating Each Deposited Layer By Ramming And Watering, Lead Up To 50 M And Lift Up To 1.5 M. 9 5.9.1:Centering And Shuttering Including Strutting, Etc. And Removal Of Form For:Foundations, Footings, Bases Of Columns, Etc For Mass Concrete 10 5.1.2:Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement - All Work Up To Plinth Level:1:1:5:3 (1 Cement 1.5 Coarse Sand :3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources) 11 5.9.5:Centering And Shuttering Including Strutting, Etc. And Removal Of Form For:Lintels, Beams, Plinth Beams, Girders Bressumers And Cantilevers 12 5.9.6:Centering And Shuttering Including Strutting, Etc. And Removal Of Form For:Columns, Pillars, Piers, Abutments, Posts And Struts 13 5.9.3:Centering And Shuttering Including Strutting, Etc. And Removal Of Form For:Suspended Floors, Roofs, Landings, Balconies And Access Platform 14 5.9.16.1:Centering And Shuttering Including Strutting, Etc. And Removal Of Form For:Edges Of Slabs And Breaks In Floors And Wallsunder 20 Cm Wide 15 5.9.7:Centering And Shuttering Including Strutting, Etc. And Removal Of Form For:Stairs, (Excluding Landings ) Except Spiral - Staircases) 16 5.9.19:Centering And Shuttering Including Strutting, Etc. And Removal Of Form For:Weather Shade, Chajjas, Corbels Etc., Including Edges 17 5.2.2:Reinforced Cement Concrete Work In Walls (Any Thickness), Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc. Up Tot Floor Five Level Excluding Cost Of Centering, Shuttering, Finishing And Reinforcement :1:1.5:3( 1 Cement : 1.5 Coarse Sand : 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources) 18 5.3:Reinforced Cement Concrete Work In Beams, Suspended Floors, Roofs, Having Slope Up To 15° Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Window Sills, Staircases And Spiral Stair Cases Up To Floor Five Level Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement, With1:1.5:3 (1 Cement : 1.5 Coarse Sand (Zone Iii) Derived From Natural Sources: 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources). 19 5.22.6:Steel Reinforcement For R.C.C Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Upto Plinth Levelthermo - Mechanically Treated Bars Of Grade Fe-500D Or More 20 5.22A.6:Steel Reinforcement For R.C.C Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Above Plinth Level.Thermo - Mechanically Treated Bars Of Grade Fe-500D Or More 21 50.6.1.5:Solid Block Masonry Using Pre Cast Solid Blocks ( Factory Made) Of Size 30X20X20Cm Or Nearest Available Size Confirming To Is 2185 Part I Of 1979 For Super Structure Up To Floor Two Level Thickness 20Cm And Above In: Cm 1:6 ( 1 Cement : 6 Coarse Sand) Etc Complete 22 50.6.2.1:Solid Block Masonry Using Pre Cast Solid Blocks (Factory Made) Of Size 30X20X15 Cm Or Nearest Available Size Confirming To Is 2185 Part I Of 1979 For Foundation And Plinth With Thickness 15Cm In: Cm 1:6 ( 1 Cement :6 Coarse Sand) Etc Complete 23 13.1.2:12 Mm Cement Plaster Of Mix:1:6 (1 Cement : 6 Fine Sand). 24 13.16.1:6 Mm Cement Plaster Of Mix:1:3 ( 1 Cement : 3 Fine Sand) 25 13.43.1:Applying One Coat Of Water Thinnable Cement Primer Of Approved Brand And Manufacture On Wall Surface:Water Thinnable Cement Primer 26 13.46.1:Finishing Walls With Acrylic Smooth Exterior Paint Of Required Shade:New Work (Two Or More Coat Applied @ 1.67 Ltr/10 Sqm Over And Including Priming Coat Of Exterior Primer Applied @ 2.20 Kg/10 Sqm) 27 13.60.1:Wall Painting With Acrylic Emulsion Paint Of Approved Brand And Manufacture To Give An Even Shade:Two Or More Coats On New Work 28 13.98.1:Wall Painting With Plastic Emulsion Paint Of Approved Brand And Manufacture To Give An Even Shade:One Or More Coats On Old Work 29 11.41.2:Providing And Laying Vitrified Floor Tiles In Different Sizes (Thickness To Be Specified By The Manufacturer) With Water Absorption Less Than 0.08% And Conforming To Is : 15622, Of Approved Make, In All Colours And Shades, Laid On 20 Mm Thick Cement Mortar 1:4(1 Cement : 4 Coarse Sand), Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete.Size Of Tile 600 X 600 Mm. 30 11.38:Providing And Laying Ceramic Glazed Floor Tiles Of Size 300X300 Mm (Thickness To Be Specified By The Manufacturer), Of Ist Quality Conforming To Is : 15622, Of Approved Make, In All Colours, Shades, Except White, Ivory, Grey, Fume Red Brown, Laid On 20 Mm Thick Bed Of Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand), Including Pointing The Joints With White Cement And Matching Pigments Etc., Complete. 31 8.31:Providing And Fixing Ist Quality Ceramic Glazed Wall Tiles Conforming To Is: 15622 (Thickness To Be Specified By The Manufacturer), Of Approved Make, In All Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Engineer-In- Charge, In Skirting, Risers Of Steps And Dados, Over 12 Mm Thick Bed Of Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) And Jointing With Grey Cement Slurry @ 3.3Kg Per Sqm, Including Pointing In White Cement Mixed With Pigment Of Matching Shade Complete. 32 10.28:Providing And Fixing Stainless Steel (Grade 304) Railing Made Of Hollow Tubes, Channels, Plates Etc., Including Welding, Grinding, Buffing, Polishing And Making Curvature (Wherever Required) And Fitting The Same With Necessary Stainless Steel Nuts And Bolts Complete, I/C Fixing The Railing With Necessary Accessories & Stainless Steel Dash Fasteners, Stainless Steel Bolts Etc., Of Required Size On The Top Of The Floor Or The Side Of Waist Slab With Suitable Arrangement As Per Approval Of Engineer-In-Charge, (For Payment Purpose Only Weight Of Stainless Steel Members Shall Be Considered Excluding Fixing Accessories Such As Nuts, Bolts, Fasteners Etc.) 33 13.62.1:Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture Of Required Colour To Give An Even Shade:Two Or More Coats On New Work Over An Under Coat Of Suitable Shade With Ordinary Paint Of Approved Brand And Manufacture . 34 50.6.3.2:Solid Block Masonry Using Pre Cast Solid Blocks (Factory Made) Of Size 40X20X10 Cm Or Nearest Available Size Confirming To Is 2185 Part I Of 1979 For Super Structure Up To Floor Two Level For 10 Cm Thick Wall In : Cm 1:6 ( 1 Cement : 6 Coarse Sand) Including Cost Of Scaffolding Complete 35 51.19.St1:Supplying And Installing Ready Made Pvc Septic Tank Including The Cost Of Carriage, Trenching, Placing At The Level Below Ground Level As Specified As Per The Direction Of Engineer In Charge (Provision For Cc/Rcc/Sand/06Mm Aggregate For The Preparation Of Bed Shall Be Paid Separately) 1. Below 15 Flush Capacity 36 19.33:Constructing Soak Pit 1.20X1.20 M Filled With Brickbats Including S.W. Drain Pipe 100 Mm Diameter And 1.20 M Long Complete As Per Standard Design. 37 18.48:Providing And Placing On Terrace (At All Floor Levels) Polyethylene Water Storage Tank :Isi 12701 Marked, With Cover And Suitable Locking Arrangement And Making Necessary Holes For Inlet, Outlet And Overflow Pipes But Without Fittings And The Base Support For Tank.
Contract Date: May 29, 2026 Contract Value : 19.42 Lakh
Government Departments No of Bidders 2
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 4
West Bengal View Result →
47.
Defence #11162658 Technical Bid
Tender for Dismantling Plain Or Corrugated Steel Sheeting Of Any Thickness As In Roof Coverings Complete All As Specified And Directed. , Supply And Fix 0.63 Mm Thick Galvanised, Corrugated Mild Steel Sheeting With Two Corrugation Side Lap, Fixed With L-Type Or J-Type Or Cranked Hook Bolts In Lieu Of Screws And Washers, In Roofs, Walls Etc. With Grade Of Zinc Coating 275 Gsm Complete All As Specified And As Directed. , S & F Pre- Painted Galvalume Aluminum Zinc Coating Gi Based Corrugated Steel Sheet 0.50Mm Thick Of An Colour Having Tensile Strength Of 550 Mpa As In Roof Covering Cladding To Wall, Fixed With Self Tapping Screws As Specified. , S&F Pre-Painted Galvalume Aluminum Zinc Coating Gi Based Plain Steel Sheet 0.50Mm Thick Of Any Colour Having Tensile Strength Of 550 Mpa As In Roof Covering/Cladding To Wall, Fixed With Self Tapping Screws As Specified. , Dismantling Floor, Hearth Or Wall Tiling Including Cement Mortar Bedding (But Not Backing), Removing Serviceable Tiles And Rubbish Off The Premises Complete All As Specified And Directed. , Demolition Of Cement Concrete In Floors N.Exc 15 Cm Thick In Ground Floor (Below Or Above Ground Level) And In Any Position All As Specified , M&L For Plain Cement Concrete 1:2:4 Type B-1 Using 20Mm Graded Stone Aggragate As In Subbase 25 Mm Thick Complete All Specified And Directed By Engr In Charge. , M&L For Non - Skid Coloured Ceramic Tiles 7 To 8 Mm Thick Area Of Each Tile Exceeding 0.18 Sqm But Not Exceeding 0.38 Sqm, In Floors Etc. Set And Jointed In Neat Cement Slurry And Pointed In White Or Coloured Cement To Match Over And Including 15Mm Thick Screed Bed Of Cm 1:4 Complete All As Specified And Directed , M&L For Non - Skid Coloured Ceramic Tiles 7 To 8 Mm Thick (Square/ Rectangular) Area Of Each Tile Exceeding 0.11 Sqm But Not Exceeding 0.18 Sqm, In Floors Etc. Set And Jointed In Neat Cement Slurry And Pointed In White Or Coloured Cement To Match Over And Including 15Mm Thick Screed Bed Of Cm 1:4 Complete All As Specified And Directed , M&L For Non - Skid Coloured Ceramic Tiles 7 To 8 Mm Thick Area Of Each Tile Exceeding 0.18 Sqm But Not Exceeding 0.38 Sqm, In Skirting Etc. Set And Jointed In Neat Cement Slurry And Pointed In White Or Coloured Cement To Match Over And Including 10Mm Thick Rendering With Cm 1:3 On Fair Faces Of Brick Work Or Concrete Surfaces As In Skirting All As Specified. , M&L For Light Shade Virified Ceramic Tiles 10 Mm Thick (Square/ Rectangular) Polished, Area Of Each Tiles Not Exceeding 0.36 Sqm, In Floors Etc. Set And Jointed In Neat Cement Slurry And Pointed In White Or Coloured Cement To Match Over And Including 15Mm Thick Screed Bed Of Cm 1:4 Complete All As Specified And Directed , Material And Labour For 450X350x7mm Thick Glazed Ceramic Tiles Coloured Set And Jointed In Neat Cement Slurry And Pointed In Coloured Cement Over And Including 10Mm Thick Rendering With Cm 1:3 On Fair Faces Of Brick Work Or Concrete Surfaces As In Dado Of Bathroom, Toilet And Kitchen All As Specified. , Demolition Of Stone Slabs Or Tiles Of Any Description Or Thickness Laid Bedded And Pointed In Any Mortar In Floors, Aprons Etc , M&L 20 Mm Thick Granite (Of Any Type) Work (Table Rubbed And Polished) In Cooking Platforms In Cm 1:4 Including Pointing In White Cement 1:2 Using Marble Dust With Admixture Of Pigment To Match With Shade Of Granite All As Specified. , M&L For Screed Bed Or Bedding Layer Of Mortar 20Mm Thick In Cm 1:4 For Laying Floor Finishes Complete All As Specified And Directed. , Demolition Of Precast Cement Concrete Articles And Precast Concrete Block Walling Built In Cement Mortar Complete All As Specified And Directed. , M & L Pre-Cast Cement Concrete Block Masonry With Solid Blocks, Exc. 10 Cm In Width And Using Plain Cement Concrete Type C-1, 1:3:6 (20Mm Graded Agg) And Setting In Cement Mortar 1:6 Complete All As Specified And Directed. , Demolition Of Reinforced Cement Concrete Of Any Description And In Any Position Not Otherwise Specifically Provided For. , M&L For Reinforced Cement Concrete Type B1 1:2:4 Using 20Mm Graded Aggragate In Slabs Supported On Walls, Beams And Columns In Floors, Roofs, Landings, Balconies, Canopies, Chajjas, Deck Slabs And In Shelves And The Like Complete All Specified And Directed , M&L Tmt Bars 10 Mm Dia., And Over Cut To Length, Bent To Shape Required, Including Cranking, Bending Spirally For Hooping For Columns, Hooking Ends And Binding With Mild Steel Wire (Annealed) Not Less Than 0.9 Mm Dia., Or Securing With Clips Qual Complete All Specified And Directed , M&L For Mils Steel Tmt Bars 05Mm Dia And Over, Upto And Including 10 Mm Dia In Stirrups, Spaces And Binders All As Specified And Directed.. , Use And Waste Of Flat Fair Finished Formwork To Soffits Of Suspended Slabs Such As Roof Slabs, Floor Slabs, Landings And Similar Work ; Not Exceeding 200Mm Thick (Horizontal Or Sloping) As Specified , Taking Down Cement Plaster On Brick, Concrete Block Wall Or Stone Walls, Etc., Including Raking Out Joints, Hacking For Key, Scrubbing Down With Water, Etc. Complete All As Specified And Directed. , M & L 10 Mm Thick Rendering In Cement Mortar 1:6 On Brick Or Concrete Surfaces Finished Even & Smooth Without Using Extra Cement Complete All As Specified And Directed. , M & L For 15 Mm Thick Plaster In Cement Mortar 1:4 On Brick Or Concrete Surfaces Finished Even & Smooth Without Using Extra Cement Complete All As Specified And Directed. , Material And Labour For Preparation Of Newly Plastered Surfaces Of Walls And Applying Two Coats Of Distemper Oil Emulsion Over A Coat Of Alkali Resistant Primer. Complete All As Specified And Directed. , Material And Labour Preparing Newly Plastered Wall Surfaces And Applying Two Coats Of Cement Base Paint On Wall Surfaces Over One Coat Of Alkali Resistant Primer Complete All As Specified And Directed. , Dismantling Of Wall And Ceiling Board Or Insulation Boards/Slabs/Blanckets/Any Thickness Including Cover Fillets Complete All As Specified And Directed. , S&F 6 Mm Thick Ply Wood, Grade Bwr, Type Bb, Fixed With Nails To Timber Frame Work On Wall Surfaces Complete All As Specified And Directed. , S&F 4 Mm Thick Ply Wood, Grade Bwr, Type Bb, Fixed With Nails To Timber Frame Work On Ceiling Surfaces Complete All As Specified And Directed. , M & L For 50 Mm Thick Ii Nd Class Hard Wood Clean Sawn Boarding With Butt Joints Fixed With Nails In Any Situation Complete All As Specified And Directed. , M & L For 2 Nd Class Hard Wood Plain Fillets, Square, Rectangular Or Triangular In Section,Wrought, Secured With Nails Or Brads, Sectional Area Exc 3 But N.Exc 6 Sq.Cm. Complete All As Specified And Directed. , M&L For Preparation Of New Wooden Surfaces Of Any Description, Not Other Wise Described, Over 10Cm Width Or Girth And Applying Two Coats Of Synthetic Enamel Paint Over A Coat Of Pink Primer Complete All As Specified And Directed. , Supply And Fix 600Mmx600mmx4mm Thick ‘E Board Classic (Make-Everest Industries Ltd) As In False Ceiling Including Supply And Fixing Gi ‘Tee Grid Frame Work Made Of Special Section Of M.S Galvanized Sheet 0.30Mm Thick , Bottom Portion Painted With Cellular Nitro Painting, Warping The Suspending Wire Around The Existing Wooden/Steel Purlin /Rafter For Suspending Grid Frame Work Of Size 605Mmx605mm Suspended With 4 Mm Dia Gi Wire @ 1200Mm C/C On Main Tee And Fixed To T-Grid With The Help Of Level Clip Or As Per Manufacturer Direction. The Section Consisting Of Main Tee 37Mmx24mmx0.60Mm, Cross Runner Tee 37Mmx24mmx0.60Mm And Perimeter Angle Of 24Mmx24mmx0.50Mm Thick. Perimeter Angle To Be Fixed To Wall With Gi Screw Of 40Mm Long @ 450 Mm C/C Along The Perimeter Of Wall Including Applying Two Coats Of Distemper Oil Emulsion Complete All As Specified And Directed , M & F For Solid Pvc Wall Lining Consisting Of 5Mm Thick Plain Colour Pvc Sheet Inclusive Of Solvent Cement And Fixing At Site On Pvc Frame As Per Specifications And Drawing Complete All As Specified And Directed. , S&F 5Mm Thick Pvc Sheet Fillet Of Width 35Mm For Wall Paneling Inclusive Of Fixing On To Wall To Make Pvc Frame As Per Specification And Drawing Complete All As Specified And Directed. , Taking Down Chowkats Or Frames With Shutters (Without Taking Off Shutters From The Frames) Area Exceeding 1.50 Sqm But Not Exc 4 Sqm. , Taking Down Chowkats Or Frames With Shutters (Without Taking Off Shutters From The Frames) Area Not Exceeding 1.50 Sqm , S & F 2Nd Class Hard Wood Plain Solid Straight Chowkats And Frames, Wrought, Framed Rebated On The Solid Rounded Or Chamfered, Put Together With Glue Pinned At Joints Complete All As Specified And Directed. , S&F 30Mm Flush Shutters, Solid Core Construction With Particle Board Core And Plywood Face Panels, Commercial Type On Both Side And Both Face Is Covered With Decorative Face Veneer With Lipping/Frame Tp Match All As Completed And Specified As Directed. , S & F 30Mm Thick 2Nd Class Hard Wood Glazed And Skeleton Shutters Open Rebated And Prepared To Receive Glass, Gauze Etc But Divided Into Squares, Edges Of Framing Plain, Chamfered Or Rounded, Fitted With Cut And Mitred Beads For Securing Glass, Etc.; Sizes Of Me-Mbers Of Shutters As Specified In Ssr Part I, Section 8, Clause 8.24 (A); Supplied And Fitted To Chowkats Complete All As Specified And As Directed , S&F Solid Pvc Door Frame Of Size 50Mm X 47Mm Made Out Of 5Mm Plain Colour Pvc Sheet Reinforced With M.S. Square Tube, Suppling & Fixing In Opening As Per Specification & Drawing Complete All As Specified And Directed. , S&F Factory Made Solid Panel Pvc Door Shutter 30 Mm Thick (Style) Consisting Of Frame Made Out Of M.S. Tubes For Top & Bottom Rails. M.S. Frame Shall Be Covered With Heat Moulded Plain Colour Pvc ‘C Channel Having A Pvc Sheet Strip Of 20Mm Width Tuck Inside With Solvent Cement For Stiles And Plain Colour Pvc Sheets For Top Rail, Lock Rail & Bottom Rail On Either Side & As Gap Insert For Top Rail & Bottom Rail; Panelling Of Lain Colour Pvc Sheet To Be Fitted In The M.S. Frame Welded / Sealed To The Stiles & Rails With Suitable Pvc Sheet Beading, And Joined Together With Solvent Cement, Suppling & Fixing In The Frame At Site As Per Specification & Drawing Complete All As Specified And Directed. , S&F Ms Window Guard Bars, Window Frames Etc Articles Confirming To Fe 410-0 Or Fe 310-0. , S & F 100Mm Size Mild Steel Butt Hinges Medium Weight Cold Rolled And Fixed. , S & F 75Mm Size Mild Steel Butt Hinges Medium Weight Cold Rolled And Fixed. , S& F Aluminium Anodised Barrel Tower Bolts 150Mm Long Of Extruded Section And Fixed , S& F Aluminium Anodised Barrel Tower Bolts 100Mm Long Of Extruded Section And Fixed , S & F 150Mm Size Extruded Aluminium Alloy Handles, Fabricated Type Anodised , S & F 100Mm Size Extruded Aluminium Alloy Handles, Fabricated Type Anodised , S & F Aluminium Alloy, Anodised, Sliding Door Bolts 300Mm Size With Hasp, Staple (Bolt Type) And Fixing Clips Of Sheets, Cast Or Extruded Sections And Fixing Bolts And Sliding Bolts Of Extruded Section Or Cast Aluminium Alloy And Fixed , S&F In Repair Pre Coated Mild Steel Floor Door Stopper ,Tongue Anodized 140Mm Length Including Vulcanised Rubber Piece Complete All As Specified And Directed. , S&F In Repair Pvc Coated 25Mm Dia Mild Steel Chromium Plated Curtain Rod Of Medium Weight And Including Fixing Brackets, Finals And Decorative End Supports Etc Complete All As Directed , M&L For Power Coated Anodised Aluminium Frame For Doors, Windows, Ventilatores With One Or More Rebated Including Joiing Cleat For Fixing Etc Complete All As Specified And Direcyed , S & F Anodised Aluminium Window And Ventilator Shutters, Fixed Type Without Sash Barsaluminium Section Weighing 0.55 Kg/M Including Necessary Joining Cleats, Glzing Clips,Rubber Packing,Anodised Aluminium Snap Beading,Screws Etc And Power Coating Of Any Colour(Thickness Of Powder Coating Not Less Than 50 Micron.) Complete All As Specified. , M & L For 4.80 Mm Sheet Glass, Ordinary Quality And Glazing With Aluminium Clip And Beading In Square Exc 0.5 Sq. M In Each Panel Complete All As Specified And Directed. , S & F Gi Steel Wire Cloth, 0.56Mm Nominal Dia Of Wire And Average Width Of Aperture 1.18Mm Etc All As Specified. , Hacking Out Old Broken Glass (Any Thickness, Size Quality Or Description) From Metal Frame Including Punching Or Drilling Out Old Glazing Pins/Spring Clips And Providing And Fixing New Ones. , S&F Sheet Glass 3Mm Thick Ordinary Quality And Glazing With Oil Putty In Squares N Exc 0.50 Sqm In Each Panel Complete All As Specified And Directed. , S&F 3Mm Thick Figured Glass, Pin Head Glazing With Oil Putty In Squares N Exc 0.50 Sqm In Each Panel Complete All As Specified And Directed. , Dismatling Of Mild Steel Work Any Description , M&L For Roof Trusses (Framed), Trussed, Purlins, Crane Gantries, Rails And Fastenings And Heavy Bracket Framing (Beam, Tee, Angle, Channel Or Flat Sections) Including Distance Pieces, Cleats Etc Conforming To Fe 290 (Gde E-165) Complete All As Specified And Directed. , M & L For Preparation Of New Or Previously Untreated Steel Surface And Applying Two Coat Of Synthetic Enamel Paint Over A Coat Of Red Oxide Primer To Steel And Iron Surfaces Of Any Description Over 10 Cm In Width Or Girth Not Otherwise Described Including Preparation Of New Steel Surfaces Complete All As Specified And Directed. , Dismantling Of Ci Soil, Rain Water Pipes, Cast And Vent Pipes Of Any Dia, Any Pattern Including All Fittings. , S&F Pvc (Swr) Pipes Single Socketed 110Mm Dia In Any Length With Rubber Ring Joints Fixed To Walls , S&F In Rep Pvc (Swr) Bends Any Radius, Bend 110Mm Dia With Access Door , S&F Pvc (Swr) Pipes 75 Mm Bore Single Socketed, In Any Length With Rubber Ring Joints, Laid In Trenches,Wall Or In Floors. , S&F In Repair Pvc Bends Any Radius 75Mm Bore , S&F In Rep Pvc (Swr) Floor Trap, 75Mm Dia Outlet, Plain With Grating Incl Jointing With Solvent Cement. , S&F In Repair Grating Doom 125Mm Dia With And Without Wast Hole Ptmt (Minimum Weight 40 Grms) , S&F In Repair Grating Doom 100Mm Dia With And Without Wast Hole Ptmt (Minimum Weight 40 Grms) , S&F In Repair 32Mm Pvc Waste Pipe For Kitchen Sink ,Whb Complete All As Specified And Directed. , S&F In Repair Pvc (Swr) Wc Connector 110Mm Dia Complete All As Specified And Directed. , S&F In Repair Vitreous China Squatting Pan Orissa Pattern Size 580 X440 Mm White With Integral Foot Rest Complete All As Specified And Directed. , S7f In Repairs 10 Ltrs Capacity Pvc Valveless Syphonic Action Type Flushing Cistern Low Level White With Inlet Ball Valve, Float, Chain And Pull And Brackets Etc Complete All As Specified And Directed. , S & F In Repair Pvc Connection 15Mm Dia 450 Mm Long With Brass Check Nuts And Washers Complete All As Specified And Directed. , S&F In Repair Vitreous China Wash Down Water Closet Pan Of Pedestal Pattern, White With P Or S Traps, Including Connecting To Trap And To Flushing Pipe Etc Complete All As Specified. , S&F In Repair Vitreous China Wash Hand Basin White Flat Back Of Size 550Mmx400 Mm Including Cutting For And Pinning In End Of Brackets,32 Mm Waste Fittings,Brass Chromium Plated For Glazed Ware Sinks,Basins Etc.With Long Screwed Shanks And Fly Nuts Flange End Bedded In Red Lead Cement And Other End Fixed.And Flush Pipe Of Polytethylene Of Low Or High Density Or Pvc 32 Mm Dia Complete All As Specified And Directed. , S&F In Repair Sinks Made Of Stainless Steel With Drainage Board 1 Mm Thick Kitchen Or Laboratory With Plugs, Washers And Wastes; Including Bedding In Cement Mortar On To Drarf Wall Or Including Fixing Cantilever Brackets And Connecting Union To Pipe, Overall Size 495Mm X 420Mm Bowl Size 410Mm X 330Mm X160mm Complete All As Specified And Directed. , S&F Vitreous China Urinals, Bowl Type 465X355x265 Mm White, Providing & Fixing Plugs, Bedding Urinal Against Wall In Cement Mortar 1:2, Securing Urinal To Plugs With And Including 60Mm Long Brass Screws, Pointing Around Urinal Back In Cement; Fixing Automatic Flushing Cistern With Brackets, Flush Pipe, Grating And Union For Discharge Pipe Complete All As Specified And Directed. , S & F In Repair Plastic Water Closet Seat Cover, White Closed Pattern With Flat Bottom, And Cover And Mild Steel Chromium Plated Or Aluminised Hinging Device Complete All As Specified And Directed. , S&F In Repair For Health Faucet (Abs Body) Mild Steel Chromium Plated Suitable For 15 Mm Dia Pipe With 1.25 Metre Long Flexible Tube And Abs Wall Hook Including Making Connections And Fixed In Position Complete In All Respect As Specified , S&F In Repairs Of Waste Fittings 32 Mm Dia, Brass, Cp For Glazed Ware Sink, Basins, Etc. With Long Screwed Shanks And Fly-Nuts, Flange End Bedded In Red Lead Cement And Other End Fixed Complete All As Specified And Directed. , S&F In Repair Cp Towel Ring Of Ptmt Fixed With Chromium Plated Brass Screws (Min Wt 90 Gms) , S&F In Repair Soap Dish, Any Type, Fiexd To Plugs With Chromium Plated Brass Screws , S&F Cp Towel Rail 600Mm Long Of Ptmt Fixed With Chromium Plated Brass Screws (Min Wt 190 Gms) , S & F In Repair Looking Mirror 600 Mm X 450 Mm Bevelled Edge Mirror Or Selected Quality Glass, Mounted On 6 Mm Thick Ac Building Board Or Commercial Plywood And Fixed To Wooden Plugs With Chromium Plated Brass Screws And Cup Washers Complete All As Specified And Directed. , Dismantling Of Water Tanks Exc 250 Ltrs & N. Exc 500 Ltrs Capacity And Removing To Store. , Dismantling Of Water Tanks Exc 500 Ltrs & N. Exc1000 Ltrs Capacity And Removing To Store. , S&F Pvc Water Storage Tanks Of 500 Ltrs Capacity Rotational Moulded (Multi Layered Cylindrical Vertical With Closed Top) Hoisted And Fixed In Position All As Specified And Directed. , S&F Pvc Water Storage Tanks Of 1000 Ltrs Capacity Rotational Moulded (Multi Layered Cylindrical Vertical With Closed Top) Hoisted And Fixed In Position All As Specified And Directed. , S & F In Repairs Fancy Type 15Mm Dia Bib Tap, Cast Copper Alloy With Crutch Or Butterfly Handle, Screwed Down For Iron Pipe Or For Brass Ferrule Complete All As Specifed. , S & F In Repair 20Mm Ball Brass Valves, High Pressure, With Polyethene Float And Flynut Complete Screwed For Iron Pipe Of 20Mm Dia All As Specified. , S&F In Repair 20Mm Gun Metal Globe Or Gate Valve With Iron Wheel Head, Screwed Both Ends For 20 Mm Dia Of Pipe And Fixed Complete All As Specified And Directed. , S & F In Repair Chromium Plated 15Mm Dia Stop Cock Cast Copper Alloy With Crutch Or Butterfly Handle, Screwed Down For Iron Pipe Or For Brass Ferrule Complete All As Specified , Supply And Fix In Rep 15Mm Pillar Taps , Cast Copper Alloy, With Capstan Heads, Chromium Plated, Screwed Down High Pressure, With Or Without Lettered Hot Or Cold With Long Screwed Shanks And Fly-Nuts, Screwed For Iron Pipe And Fixed Complete All As Specified And Directed. , S&F In Repair 15Mm Brass Cp Mixer For Mixing Hot And Cold Water (Wall Mixer) Screwed Down For Iron Pipe Andd Fixed In Repairs For Bath Shower And Kichen Sink With Complete All As Specified And Directed. , S&F In Repair 15 Mm Brass Cp Basin Mixer Unit With All Fittings Required Complete All As Specified And Directed. , S& F In Repair Sheet Glass Shelf Assembly Consisting Of 5.5Mm Thick Sheet Glass Shelf 12Cm Wide With Chromium Plated Bracket Guard And Railing 60Cm Long Complete All As Specified And Directed. , S& F In Repair Chromium Plated Shower Roses With Or Without Swivel Joints, Any Size, Including Fixing To Steel Pipe Or Union Complete All As Specified And Directed. , Taking Up Or Down 15 Mm Bore Steel Water Tubing And Connections Including Clfor Refixing Or Removal To Store , S&F 15Mm Bore Steel Water Tubes, Medium Grade, Galvanised With All Fittings And Fixed Complete To Walls/Ceilings Or Laid In Trenches Complete All As Specified And Directed. , Taking Up Or Down 20 Mm Bore Steel Water Tubing And Connections Including Cleaning Or Refixing Or Removal To Store , S&F 20 Mm Bore Steel Water Tubes, Medium Grade, Galvanised With All Fittings And Fixed Complete To Walls/Ceilings Or Laid In Trenches. , Supply & Fixing In Repair 3-Layer Pp-R Polypropylene Random Copolymer) Concealed Pipes Of 20 Mm Outer Dia Sdr 7.4 (Pn16) Uv Stabilized And Antimicrobial Fusion Welded Having Thermal Stability For Hot & Cold Water Supply Including All Pp-R Plain & Brass Threaded Polypropylene Random Fittings Fixed Complete To Walls, Ceilings Or In Floors Etc. With All Fittings And Fixed Complete To Wall And Ceiling Or Laid In Floors And Making Connection With Old Gi Tube/Ppr Pipe Using Suitable Section Complete Leakproof All As Specified And As Directed. , Supply & Fixing In Repair 3-Layer Pp-R Polypropylene Random Copolymer) Concealed Pipes Of 16 Mm Outer Dia Sdr 7.4 (Pn16) Uv Stabilized And Antimicrobial Fusion Welded Having Thermal Stability For Hot & Cold Water Supply Including All Pp-R Plain & Brass Threaded Polypropylene Random Fittings Fixed Complete To Walls, Ceilings Or In Floors Etc. With All Fittings And Fixed Complete To Wall And Ceiling Or Laid In Floors And Making Connection With Old Gi Tube/Ppr Pipe Using Suitable Section Complete Leakproof All As Specified And As Directed. , M & L For 100 Mm Thick Cement Concrete Type D- 2,1:4:8 (40Mm Graded Aggregate) As In Sub Base Complete All As Specified And Directed. , M & L Providing And Laying 60Mm Thick Factorymade Chamfered Edge Cement Concrete Paver Block Of M-35 Grade With Approved Colour,Design & Pattern As In Footparth, Parks,Lawns, Drive Ways Or Light Traffic Parking Etc.,Of Required Strength, Thickness & Size/Shape, Made By Table Vibratory Method Usingpu Mould, Laid In Required Colour & Pattern Over And Including 50Mm Thick Compactedbed Of Fine Sand, Compacting And Proper Embedding/ Laying Of Inter Locking Paverblocks Into The Sand Bedding Layer Through Vibratory Compaction By Using Plate Vibrator, Filling The Joints With Sand And Cutting Of Paver Blocks As Per Required Sizeand Pattern, Finishing And Sweeping Extra Sand Complete All As Specified . , M&L Chequered Cement Concrete Tiles 20Cmx20cmx25mm Thick With Grey Cement And Pigment, Set Jointed And Pointed In Neat Cement Slurry In Floors Completed All As Specified And Directed By Engr-In-Charge. , Disconnecting Existing Water Tanks Of Capacity Exc 250 Ltrs But N Exc 500 Ltrs, Setting Aside (Or Lowering If Required) For Repairs, Cleaning, Etc. And Hoisting If Required Reconnecting And Re-Fixing In Position Incl Cleaning And Removing All Scale And Dirt Etc, From Tanks And From Mouths Of Circulating Pipes Etc Complete All As Specified And Directed. , Disconnecting Existing Water Tanks Of Capacity Exc 500 Ltrs But N Exc 1000 Ltrs, Setting Aside (Or Lowering If Required) For Repairs, Cleaning, Etc. And Hoisting If Required Reconnecting And Re-Fixing In Position Incl Cleaning And Removing All Scale And Dirt Etc, From Tanks And From Mouths Of Circulating Pipes Etc Complete All As Specified And Directed.
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 6
Arunachal Pradesh View Result →
48.
Defence #11162657 Technical Bid
Tender for Dismantling Plain Or Corrugated Steel Sheeting Of Any Thickness As In Roof Coverings Complete All As Specified And Directed. , Supply And Fix 0.63 Mm Thick Galvanised, Corrugated Mild Steel Sheeting With Two Corrugation Side Lap, Fixed With L-Type Or J-Type Or Cranked Hook Bolts In Lieu Of Screws And Washers, In Roofs, Walls Etc. With Grade Of Zinc Coating 275 Gsm Complete All As Specified And As Directed. , S & F Pre- Painted Galvalume Aluminum Zinc Coating Gi Based Corrugated Steel Sheet 0.50Mm Thick Of An Colour Having Tensile Strength Of 550 Mpa As In Roof Covering Cladding To Wall, Fixed With Self Tapping Screws As Specified. , S&F Pre-Painted Galvalume Aluminum Zinc Coating Gi Based Plain Steel Sheet 0.50Mm Thick Of Any Colour Having Tensile Strength Of 550 Mpa As In Roof Covering/Cladding To Wall, Fixed With Self Tapping Screws As Specified. , Dismantling Floor, Hearth Or Wall Tiling Including Cement Mortar Bedding (But Not Backing), Removing Serviceable Tiles And Rubbish Off The Premises Complete All As Specified And Directed. , Demolition Of Cement Concrete In Floors N.Exc 15 Cm Thick In Ground Floor (Below Or Above Ground Level) And In Any Position All As Specified , M&L For Plain Cement Concrete 1:2:4 Type B-1 Using 20Mm Graded Stone Aggragate As In Subbase 25 Mm Thick Complete All Specified And Directed By Engr In Charge. , M&L For Non - Skid Coloured Ceramic Tiles 7 To 8 Mm Thick Area Of Each Tile Exceeding 0.18 Sqm But Not Exceeding 0.38 Sqm, In Floors Etc. Set And Jointed In Neat Cement Slurry And Pointed In White Or Coloured Cement To Match Over And Including 15Mm Thick Screed Bed Of Cm 1:4 Complete All As Specified And Directed , M&L For Non - Skid Coloured Ceramic Tiles 7 To 8 Mm Thick (Square/ Rectangular) Area Of Each Tile Exceeding 0.11 Sqm But Not Exceeding 0.18 Sqm, In Floors Etc. Set And Jointed In Neat Cement Slurry And Pointed In White Or Coloured Cement To Match Over And Including 15Mm Thick Screed Bed Of Cm 1:4 Complete All As Specified And Directed , M&L For Non - Skid Coloured Ceramic Tiles 7 To 8 Mm Thick Area Of Each Tile Exceeding 0.18 Sqm But Not Exceeding 0.38 Sqm, In Skirting Etc. Set And Jointed In Neat Cement Slurry And Pointed In White Or Coloured Cement To Match Over And Including 10Mm Thick Rendering With Cm 1:3 On Fair Faces Of Brick Work Or Concrete Surfaces As In Skirting All As Specified. , M&L For Light Shade Virified Ceramic Tiles 10 Mm Thick (Square/ Rectangular) Polished, Area Of Each Tiles Not Exceeding 0.36 Sqm, In Floors Etc. Set And Jointed In Neat Cement Slurry And Pointed In White Or Coloured Cement To Match Over And Including 15Mm Thick Screed Bed Of Cm 1:4 Complete All As Specified And Directed , Material And Labour For 450X350x7mm Thick Glazed Ceramic Tiles Coloured Set And Jointed In Neat Cement Slurry And Pointed In Coloured Cement Over And Including 10Mm Thick Rendering With Cm 1:3 On Fair Faces Of Brick Work Or Concrete Surfaces As In Dado Of Bathroom, Toilet And Kitchen All As Specified. , Demolition Of Stone Slabs Or Tiles Of Any Description Or Thickness Laid Bedded And Pointed In Any Mortar In Floors, Aprons Etc , M&L 20 Mm Thick Granite (Of Any Type) Work (Table Rubbed And Polished) In Cooking Platforms In Cm 1:4 Including Pointing In White Cement 1:2 Using Marble Dust With Admixture Of Pigment To Match With Shade Of Granite All As Specified. , M&L For Screed Bed Or Bedding Layer Of Mortar 20Mm Thick In Cm 1:4 For Laying Floor Finishes Complete All As Specified And Directed. , Demolition Of Precast Cement Concrete Articles And Precast Concrete Block Walling Built In Cement Mortar Complete All As Specified And Directed. , M & L Pre-Cast Cement Concrete Block Masonry With Solid Blocks, Exc. 10 Cm In Width And Using Plain Cement Concrete Type C-1, 1:3:6 (20Mm Graded Agg) And Setting In Cement Mortar 1:6 Complete All As Specified And Directed. , Demolition Of Reinforced Cement Concrete Of Any Description And In Any Position Not Otherwise Specifically Provided For. , M&L For Reinforced Cement Concrete Type B1 1:2:4 Using 20Mm Graded Aggragate In Slabs Supported On Walls, Beams And Columns In Floors, Roofs, Landings, Balconies, Canopies, Chajjas, Deck Slabs And In Shelves And The Like Complete All Specified And Directed , M&L Tmt Bars 10 Mm Dia., And Over Cut To Length, Bent To Shape Required, Including Cranking, Bending Spirally For Hooping For Columns, Hooking Ends And Binding With Mild Steel Wire (Annealed) Not Less Than 0.9 Mm Dia., Or Securing With Clips Qual Complete All Specified And Directed , M&L For Mils Steel Tmt Bars 05Mm Dia And Over, Upto And Including 10 Mm Dia In Stirrups, Spaces And Binders All As Specified And Directed.. , Use And Waste Of Flat Fair Finished Formwork To Soffits Of Suspended Slabs Such As Roof Slabs, Floor Slabs, Landings And Similar Work ; Not Exceeding 200Mm Thick (Horizontal Or Sloping) As Specified , Taking Down Cement Plaster On Brick, Concrete Block Wall Or Stone Walls, Etc., Including Raking Out Joints, Hacking For Key, Scrubbing Down With Water, Etc. Complete All As Specified And Directed. , M & L 10 Mm Thick Rendering In Cement Mortar 1:6 On Brick Or Concrete Surfaces Finished Even & Smooth Without Using Extra Cement Complete All As Specified And Directed. , M & L For 15 Mm Thick Plaster In Cement Mortar 1:4 On Brick Or Concrete Surfaces Finished Even & Smooth Without Using Extra Cement Complete All As Specified And Directed. , Material And Labour For Preparation Of Newly Plastered Surfaces Of Walls And Applying Two Coats Of Distemper Oil Emulsion Over A Coat Of Alkali Resistant Primer. Complete All As Specified And Directed. , Material And Labour Preparing Newly Plastered Wall Surfaces And Applying Two Coats Of Cement Base Paint On Wall Surfaces Over One Coat Of Alkali Resistant Primer Complete All As Specified And Directed. , Dismantling Of Wall And Ceiling Board Or Insulation Boards/Slabs/Blanckets/Any Thickness Including Cover Fillets Complete All As Specified And Directed. , S&F 6 Mm Thick Ply Wood, Grade Bwr, Type Bb, Fixed With Nails To Timber Frame Work On Wall Surfaces Complete All As Specified And Directed. , S&F 4 Mm Thick Ply Wood, Grade Bwr, Type Bb, Fixed With Nails To Timber Frame Work On Ceiling Surfaces Complete All As Specified And Directed. , M & L For 50 Mm Thick Ii Nd Class Hard Wood Clean Sawn Boarding With Butt Joints Fixed With Nails In Any Situation Complete All As Specified And Directed. , M & L For 2 Nd Class Hard Wood Plain Fillets, Square, Rectangular Or Triangular In Section,Wrought, Secured With Nails Or Brads, Sectional Area Exc 3 But N.Exc 6 Sq.Cm. Complete All As Specified And Directed. , M&L For Preparation Of New Wooden Surfaces Of Any Description, Not Other Wise Described, Over 10Cm Width Or Girth And Applying Two Coats Of Synthetic Enamel Paint Over A Coat Of Pink Primer Complete All As Specified And Directed. , Supply And Fix 600Mmx600mmx4mm Thick ‘E Board Classic (Make-Everest Industries Ltd) As In False Ceiling Including Supply And Fixing Gi ‘Tee Grid Frame Work Made Of Special Section Of M.S Galvanized Sheet 0.30Mm Thick , Bottom Portion Painted With Cellular Nitro Painting, Warping The Suspending Wire Around The Existing Wooden/Steel Purlin /Rafter For Suspending Grid Frame Work Of Size 605Mmx605mm Suspended With 4 Mm Dia Gi Wire @ 1200Mm C/C On Main Tee And Fixed To T-Grid With The Help Of Level Clip Or As Per Manufacturer Direction. The Section Consisting Of Main Tee 37Mmx24mmx0.60Mm, Cross Runner Tee 37Mmx24mmx0.60Mm And Perimeter Angle Of 24Mmx24mmx0.50Mm Thick. Perimeter Angle To Be Fixed To Wall With Gi Screw Of 40Mm Long @ 450 Mm C/C Along The Perimeter Of Wall Including Applying Two Coats Of Distemper Oil Emulsion Complete All As Specified And Directed , M & F For Solid Pvc Wall Lining Consisting Of 5Mm Thick Plain Colour Pvc Sheet Inclusive Of Solvent Cement And Fixing At Site On Pvc Frame As Per Specifications And Drawing Complete All As Specified And Directed. , S&F 5Mm Thick Pvc Sheet Fillet Of Width 35Mm For Wall Paneling Inclusive Of Fixing On To Wall To Make Pvc Frame As Per Specification And Drawing Complete All As Specified And Directed. , Taking Down Chowkats Or Frames With Shutters (Without Taking Off Shutters From The Frames) Area Exceeding 1.50 Sqm But Not Exc 4 Sqm. , Taking Down Chowkats Or Frames With Shutters (Without Taking Off Shutters From The Frames) Area Not Exceeding 1.50 Sqm , S & F 2Nd Class Hard Wood Plain Solid Straight Chowkats And Frames, Wrought, Framed Rebated On The Solid Rounded Or Chamfered, Put Together With Glue Pinned At Joints Complete All As Specified And Directed. , S&F 30Mm Flush Shutters, Solid Core Construction With Particle Board Core And Plywood Face Panels, Commercial Type On Both Side And Both Face Is Covered With Decorative Face Veneer With Lipping/Frame Tp Match All As Completed And Specified As Directed. , S & F 30Mm Thick 2Nd Class Hard Wood Glazed And Skeleton Shutters Open Rebated And Prepared To Receive Glass, Gauze Etc But Divided Into Squares, Edges Of Framing Plain, Chamfered Or Rounded, Fitted With Cut And Mitred Beads For Securing Glass, Etc.; Sizes Of Me-Mbers Of Shutters As Specified In Ssr Part I, Section 8, Clause 8.24 (A); Supplied And Fitted To Chowkats Complete All As Specified And As Directed , S&F Solid Pvc Door Frame Of Size 50Mm X 47Mm Made Out Of 5Mm Plain Colour Pvc Sheet Reinforced With M.S. Square Tube, Suppling & Fixing In Opening As Per Specification & Drawing Complete All As Specified And Directed. , S&F Factory Made Solid Panel Pvc Door Shutter 30 Mm Thick (Style) Consisting Of Frame Made Out Of M.S. Tubes For Top & Bottom Rails. M.S. Frame Shall Be Covered With Heat Moulded Plain Colour Pvc ‘C Channel Having A Pvc Sheet Strip Of 20Mm Width Tuck Inside With Solvent Cement For Stiles And Plain Colour Pvc Sheets For Top Rail, Lock Rail & Bottom Rail On Either Side & As Gap Insert For Top Rail & Bottom Rail; Panelling Of Lain Colour Pvc Sheet To Be Fitted In The M.S. Frame Welded / Sealed To The Stiles & Rails With Suitable Pvc Sheet Beading, And Joined Together With Solvent Cement, Suppling & Fixing In The Frame At Site As Per Specification & Drawing Complete All As Specified And Directed. , S&F Ms Window Guard Bars, Window Frames Etc Articles Confirming To Fe 410-0 Or Fe 310-0. , S & F 100Mm Size Mild Steel Butt Hinges Medium Weight Cold Rolled And Fixed. , S & F 75Mm Size Mild Steel Butt Hinges Medium Weight Cold Rolled And Fixed. , S& F Aluminium Anodised Barrel Tower Bolts 150Mm Long Of Extruded Section And Fixed , S& F Aluminium Anodised Barrel Tower Bolts 100Mm Long Of Extruded Section And Fixed , S & F 150Mm Size Extruded Aluminium Alloy Handles, Fabricated Type Anodised , S & F 100Mm Size Extruded Aluminium Alloy Handles, Fabricated Type Anodised , S & F Aluminium Alloy, Anodised, Sliding Door Bolts 300Mm Size With Hasp, Staple (Bolt Type) And Fixing Clips Of Sheets, Cast Or Extruded Sections And Fixing Bolts And Sliding Bolts Of Extruded Section Or Cast Aluminium Alloy And Fixed , S&F In Repair Pre Coated Mild Steel Floor Door Stopper ,Tongue Anodized 140Mm Length Including Vulcanised Rubber Piece Complete All As Specified And Directed. , S&F In Repair Pvc Coated 25Mm Dia Mild Steel Chromium Plated Curtain Rod Of Medium Weight And Including Fixing Brackets, Finals And Decorative End Supports Etc Complete All As Directed , M&L For Power Coated Anodised Aluminium Frame For Doors, Windows, Ventilatores With One Or More Rebated Including Joiing Cleat For Fixing Etc Complete All As Specified And Direcyed , S & F Anodised Aluminium Window And Ventilator Shutters, Fixed Type Without Sash Barsaluminium Section Weighing 0.55 Kg/M Including Necessary Joining Cleats, Glzing Clips,Rubber Packing,Anodised Aluminium Snap Beading,Screws Etc And Power Coating Of Any Colour(Thickness Of Powder Coating Not Less Than 50 Micron.) Complete All As Specified. , M & L For 4.80 Mm Sheet Glass, Ordinary Quality And Glazing With Aluminium Clip And Beading In Square Exc 0.5 Sq. M In Each Panel Complete All As Specified And Directed. , S & F Gi Steel Wire Cloth, 0.56Mm Nominal Dia Of Wire And Average Width Of Aperture 1.18Mm Etc All As Specified. , Hacking Out Old Broken Glass (Any Thickness, Size Quality Or Description) From Metal Frame Including Punching Or Drilling Out Old Glazing Pins/Spring Clips And Providing And Fixing New Ones. , S&F Sheet Glass 3Mm Thick Ordinary Quality And Glazing With Oil Putty In Squares N Exc 0.50 Sqm In Each Panel Complete All As Specified And Directed. , S&F 3Mm Thick Figured Glass, Pin Head Glazing With Oil Putty In Squares N Exc 0.50 Sqm In Each Panel Complete All As Specified And Directed. , Dismatling Of Mild Steel Work Any Description , M&L For Roof Trusses (Framed), Trussed, Purlins, Crane Gantries, Rails And Fastenings And Heavy Bracket Framing (Beam, Tee, Angle, Channel Or Flat Sections) Including Distance Pieces, Cleats Etc Conforming To Fe 290 (Gde E-165) Complete All As Specified And Directed. , M & L For Preparation Of New Or Previously Untreated Steel Surface And Applying Two Coat Of Synthetic Enamel Paint Over A Coat Of Red Oxide Primer To Steel And Iron Surfaces Of Any Description Over 10 Cm In Width Or Girth Not Otherwise Described Including Preparation Of New Steel Surfaces Complete All As Specified And Directed. , Dismantling Of Ci Soil, Rain Water Pipes, Cast And Vent Pipes Of Any Dia, Any Pattern Including All Fittings. , S&F Pvc (Swr) Pipes Single Socketed 110Mm Dia In Any Length With Rubber Ring Joints Fixed To Walls , S&F In Rep Pvc (Swr) Bends Any Radius, Bend 110Mm Dia With Access Door , S&F Pvc (Swr) Pipes 75 Mm Bore Single Socketed, In Any Length With Rubber Ring Joints, Laid In Trenches,Wall Or In Floors. , S&F In Repair Pvc Bends Any Radius 75Mm Bore , S&F In Rep Pvc (Swr) Floor Trap, 75Mm Dia Outlet, Plain With Grating Incl Jointing With Solvent Cement. , S&F In Repair Grating Doom 125Mm Dia With And Without Wast Hole Ptmt (Minimum Weight 40 Grms) , S&F In Repair Grating Doom 100Mm Dia With And Without Wast Hole Ptmt (Minimum Weight 40 Grms) , S&F In Repair 32Mm Pvc Waste Pipe For Kitchen Sink ,Whb Complete All As Specified And Directed. , S&F In Repair Pvc (Swr) Wc Connector 110Mm Dia Complete All As Specified And Directed. , S&F In Repair Vitreous China Squatting Pan Orissa Pattern Size 580 X440 Mm White With Integral Foot Rest Complete All As Specified And Directed. , S7f In Repairs 10 Ltrs Capacity Pvc Valveless Syphonic Action Type Flushing Cistern Low Level White With Inlet Ball Valve, Float, Chain And Pull And Brackets Etc Complete All As Specified And Directed. , S & F In Repair Pvc Connection 15Mm Dia 450 Mm Long With Brass Check Nuts And Washers Complete All As Specified And Directed. , S&F In Repair Vitreous China Wash Down Water Closet Pan Of Pedestal Pattern, White With P Or S Traps, Including Connecting To Trap And To Flushing Pipe Etc Complete All As Specified. , S&F In Repair Vitreous China Wash Hand Basin White Flat Back Of Size 550Mmx400 Mm Including Cutting For And Pinning In End Of Brackets,32 Mm Waste Fittings,Brass Chromium Plated For Glazed Ware Sinks,Basins Etc.With Long Screwed Shanks And Fly Nuts Flange End Bedded In Red Lead Cement And Other End Fixed.And Flush Pipe Of Polytethylene Of Low Or High Density Or Pvc 32 Mm Dia Complete All As Specified And Directed. , S&F In Repair Sinks Made Of Stainless Steel With Drainage Board 1 Mm Thick Kitchen Or Laboratory With Plugs, Washers And Wastes; Including Bedding In Cement Mortar On To Drarf Wall Or Including Fixing Cantilever Brackets And Connecting Union To Pipe, Overall Size 495Mm X 420Mm Bowl Size 410Mm X 330Mm X160mm Complete All As Specified And Directed. , S&F Vitreous China Urinals, Bowl Type 465X355x265 Mm White, Providing & Fixing Plugs, Bedding Urinal Against Wall In Cement Mortar 1:2, Securing Urinal To Plugs With And Including 60Mm Long Brass Screws, Pointing Around Urinal Back In Cement; Fixing Automatic Flushing Cistern With Brackets, Flush Pipe, Grating And Union For Discharge Pipe Complete All As Specified And Directed. , S & F In Repair Plastic Water Closet Seat Cover, White Closed Pattern With Flat Bottom, And Cover And Mild Steel Chromium Plated Or Aluminised Hinging Device Complete All As Specified And Directed. , S&F In Repair For Health Faucet (Abs Body) Mild Steel Chromium Plated Suitable For 15 Mm Dia Pipe With 1.25 Metre Long Flexible Tube And Abs Wall Hook Including Making Connections And Fixed In Position Complete In All Respect As Specified , S&F In Repairs Of Waste Fittings 32 Mm Dia, Brass, Cp For Glazed Ware Sink, Basins, Etc. With Long Screwed Shanks And Fly-Nuts, Flange End Bedded In Red Lead Cement And Other End Fixed Complete All As Specified And Directed. , S&F In Repair Cp Towel Ring Of Ptmt Fixed With Chromium Plated Brass Screws (Min Wt 90 Gms) , S&F In Repair Soap Dish, Any Type, Fiexd To Plugs With Chromium Plated Brass Screws , S&F Cp Towel Rail 600Mm Long Of Ptmt Fixed With Chromium Plated Brass Screws (Min Wt 190 Gms) , S & F In Repair Looking Mirror 600 Mm X 450 Mm Bevelled Edge Mirror Or Selected Quality Glass, Mounted On 6 Mm Thick Ac Building Board Or Commercial Plywood And Fixed To Wooden Plugs With Chromium Plated Brass Screws And Cup Washers Complete All As Specified And Directed. , Dismantling Of Water Tanks Exc 250 Ltrs & N. Exc 500 Ltrs Capacity And Removing To Store. , Dismantling Of Water Tanks Exc 500 Ltrs & N. Exc1000 Ltrs Capacity And Removing To Store. , S&F Pvc Water Storage Tanks Of 500 Ltrs Capacity Rotational Moulded (Multi Layered Cylindrical Vertical With Closed Top) Hoisted And Fixed In Position All As Specified And Directed. , S&F Pvc Water Storage Tanks Of 1000 Ltrs Capacity Rotational Moulded (Multi Layered Cylindrical Vertical With Closed Top) Hoisted And Fixed In Position All As Specified And Directed. , S & F In Repairs Fancy Type 15Mm Dia Bib Tap, Cast Copper Alloy With Crutch Or Butterfly Handle, Screwed Down For Iron Pipe Or For Brass Ferrule Complete All As Specifed. , S & F In Repair 20Mm Ball Brass Valves, High Pressure, With Polyethene Float And Flynut Complete Screwed For Iron Pipe Of 20Mm Dia All As Specified. , S&F In Repair 20Mm Gun Metal Globe Or Gate Valve With Iron Wheel Head, Screwed Both Ends For 20 Mm Dia Of Pipe And Fixed Complete All As Specified And Directed. , S & F In Repair Chromium Plated 15Mm Dia Stop Cock Cast Copper Alloy With Crutch Or Butterfly Handle, Screwed Down For Iron Pipe Or For Brass Ferrule Complete All As Specified , Supply And Fix In Rep 15Mm Pillar Taps , Cast Copper Alloy, With Capstan Heads, Chromium Plated, Screwed Down High Pressure, With Or Without Lettered Hot Or Cold With Long Screwed Shanks And Fly-Nuts, Screwed For Iron Pipe And Fixed Complete All As Specified And Directed. , S&F In Repair 15Mm Brass Cp Mixer For Mixing Hot And Cold Water (Wall Mixer) Screwed Down For Iron Pipe Andd Fixed In Repairs For Bath Shower And Kichen Sink With Complete All As Specified And Directed. , S&F In Repair 15 Mm Brass Cp Basin Mixer Unit With All Fittings Required Complete All As Specified And Directed. , S& F In Repair Sheet Glass Shelf Assembly Consisting Of 5.5Mm Thick Sheet Glass Shelf 12Cm Wide With Chromium Plated Bracket Guard And Railing 60Cm Long Complete All As Specified And Directed. , S& F In Repair Chromium Plated Shower Roses With Or Without Swivel Joints, Any Size, Including Fixing To Steel Pipe Or Union Complete All As Specified And Directed. , Taking Up Or Down 15 Mm Bore Steel Water Tubing And Connections Including Clfor Refixing Or Removal To Store , S&F 15Mm Bore Steel Water Tubes, Medium Grade, Galvanised With All Fittings And Fixed Complete To Walls/Ceilings Or Laid In Trenches Complete All As Specified And Directed. , Taking Up Or Down 20 Mm Bore Steel Water Tubing And Connections Including Cleaning Or Refixing Or Removal To Store , S&F 20 Mm Bore Steel Water Tubes, Medium Grade, Galvanised With All Fittings And Fixed Complete To Walls/Ceilings Or Laid In Trenches. , Supply & Fixing In Repair 3-Layer Pp-R Polypropylene Random Copolymer) Concealed Pipes Of 20 Mm Outer Dia Sdr 7.4 (Pn16) Uv Stabilized And Antimicrobial Fusion Welded Having Thermal Stability For Hot & Cold Water Supply Including All Pp-R Plain & Brass Threaded Polypropylene Random Fittings Fixed Complete To Walls, Ceilings Or In Floors Etc. With All Fittings And Fixed Complete To Wall And Ceiling Or Laid In Floors And Making Connection With Old Gi Tube/Ppr Pipe Using Suitable Section Complete Leakproof All As Specified And As Directed. , Supply & Fixing In Repair 3-Layer Pp-R Polypropylene Random Copolymer) Concealed Pipes Of 16 Mm Outer Dia Sdr 7.4 (Pn16) Uv Stabilized And Antimicrobial Fusion Welded Having Thermal Stability For Hot & Cold Water Supply Including All Pp-R Plain & Brass Threaded Polypropylene Random Fittings Fixed Complete To Walls, Ceilings Or In Floors Etc. With All Fittings And Fixed Complete To Wall And Ceiling Or Laid In Floors And Making Connection With Old Gi Tube/Ppr Pipe Using Suitable Section Complete Leakproof All As Specified And As Directed. , M & L For 100 Mm Thick Cement Concrete Type D- 2,1:4:8 (40Mm Graded Aggregate) As In Sub Base Complete All As Specified And Directed. , M & L Providing And Laying 60Mm Thick Factorymade Chamfered Edge Cement Concrete Paver Block Of M-35 Grade With Approved Colour,Design & Pattern As In Footparth, Parks,Lawns, Drive Ways Or Light Traffic Parking Etc.,Of Required Strength, Thickness & Size/Shape, Made By Table Vibratory Method Usingpu Mould, Laid In Required Colour & Pattern Over And Including 50Mm Thick Compactedbed Of Fine Sand, Compacting And Proper Embedding/ Laying Of Inter Locking Paverblocks Into The Sand Bedding Layer Through Vibratory Compaction By Using Plate Vibrator, Filling The Joints With Sand And Cutting Of Paver Blocks As Per Required Sizeand Pattern, Finishing And Sweeping Extra Sand Complete All As Specified . , M&L Chequered Cement Concrete Tiles 20Cmx20cmx25mm Thick With Grey Cement And Pigment, Set Jointed And Pointed In Neat Cement Slurry In Floors Completed All As Specified And Directed By Engr-In-Charge. , Disconnecting Existing Water Tanks Of Capacity Exc 250 Ltrs But N Exc 500 Ltrs, Setting Aside (Or Lowering If Required) For Repairs, Cleaning, Etc. And Hoisting If Required Reconnecting And Re-Fixing In Position Incl Cleaning And Removing All Scale And Dirt Etc, From Tanks And From Mouths Of Circulating Pipes Etc Complete All As Specified And Directed. , Disconnecting Existing Water Tanks Of Capacity Exc 500 Ltrs But N Exc 1000 Ltrs, Setting Aside (Or Lowering If Required) For Repairs, Cleaning, Etc. And Hoisting If Required Reconnecting And Re-Fixing In Position Incl Cleaning And Removing All Scale And Dirt Etc, From Tanks And From Mouths Of Circulating Pipes Etc Complete All As Specified And Directed.
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 7
Arunachal Pradesh View Result →
49.
Defence #11162656 AOC
Tender for Dismantling Plain Or Corrugated Steel Sheeting Of Any Thickness As In Roof Coverings Complete All As Specified And Directed. , Supply And Fix 0.63 Mm Thick Galvanised, Corrugated Mild Steel Sheeting With Two Corrugation Side Lap, Fixed With L-Type Or J-Type Or Cranked Hook Bolts In Lieu Of Screws And Washers, In Roofs, Walls Etc. With Grade Of Zinc Coating 275 Gsm Complete All As Specified And As Directed. , S & F Pre- Painted Galvalume Aluminum Zinc Coating Gi Based Corrugated Steel Sheet 0.50Mm Thick Of An Colour Having Tensile Strength Of 550 Mpa As In Roof Covering Cladding To Wall, Fixed With Self Tapping Screws As Specified. , S&F Pre-Painted Galvalume Aluminum Zinc Coating Gi Based Plain Steel Sheet 0.50Mm Thick Of Any Colour Having Tensile Strength Of 550 Mpa As In Roof Covering/Cladding To Wall, Fixed With Self Tapping Screws As Specified. , Dismantling Floor, Hearth Or Wall Tiling Including Cement Mortar Bedding (But Not Backing), Removing Serviceable Tiles And Rubbish Off The Premises Complete All As Specified And Directed. , Demolition Of Cement Concrete In Floors N.Exc 15 Cm Thick In Ground Floor (Below Or Above Ground Level) And In Any Position All As Specified , M&L For Plain Cement Concrete 1:2:4 Type B-1 Using 20Mm Graded Stone Aggragate As In Subbase 25 Mm Thick Complete All Specified And Directed By Engr In Charge. , M&L For Non - Skid Coloured Ceramic Tiles 7 To 8 Mm Thick Area Of Each Tile Exceeding 0.18 Sqm But Not Exceeding 0.38 Sqm, In Floors Etc. Set And Jointed In Neat Cement Slurry And Pointed In White Or Coloured Cement To Match Over And Including 15Mm Thick Screed Bed Of Cm 1:4 Complete All As Specified And Directed , M&L For Non - Skid Coloured Ceramic Tiles 7 To 8 Mm Thick (Square/ Rectangular) Area Of Each Tile Exceeding 0.11 Sqm But Not Exceeding 0.18 Sqm, In Floors Etc. Set And Jointed In Neat Cement Slurry And Pointed In White Or Coloured Cement To Match Over And Including 15Mm Thick Screed Bed Of Cm 1:4 Complete All As Specified And Directed , M&L For Non - Skid Coloured Ceramic Tiles 7 To 8 Mm Thick Area Of Each Tile Exceeding 0.18 Sqm But Not Exceeding 0.38 Sqm, In Skirting Etc. Set And Jointed In Neat Cement Slurry And Pointed In White Or Coloured Cement To Match Over And Including 10Mm Thick Rendering With Cm 1:3 On Fair Faces Of Brick Work Or Concrete Surfaces As In Skirting All As Specified. , M&L For Light Shade Virified Ceramic Tiles 10 Mm Thick (Square/ Rectangular) Polished, Area Of Each Tiles Not Exceeding 0.36 Sqm, In Floors Etc. Set And Jointed In Neat Cement Slurry And Pointed In White Or Coloured Cement To Match Over And Including 15Mm Thick Screed Bed Of Cm 1:4 Complete All As Specified And Directed , Material And Labour For 450X350x7mm Thick Glazed Ceramic Tiles Coloured Set And Jointed In Neat Cement Slurry And Pointed In Coloured Cement Over And Including 10Mm Thick Rendering With Cm 1:3 On Fair Faces Of Brick Work Or Concrete Surfaces As In Dado Of Bathroom, Toilet And Kitchen All As Specified. , Demolition Of Stone Slabs Or Tiles Of Any Description Or Thickness Laid Bedded And Pointed In Any Mortar In Floors, Aprons Etc , M&L 20 Mm Thick Granite (Of Any Type) Work (Table Rubbed And Polished) In Cooking Platforms In Cm 1:4 Including Pointing In White Cement 1:2 Using Marble Dust With Admixture Of Pigment To Match With Shade Of Granite All As Specified. , M&L For Screed Bed Or Bedding Layer Of Mortar 20Mm Thick In Cm 1:4 For Laying Floor Finishes Complete All As Specified And Directed. , Demolition Of Precast Cement Concrete Articles And Precast Concrete Block Walling Built In Cement Mortar Complete All As Specified And Directed. , M & L Pre-Cast Cement Concrete Block Masonry With Solid Blocks, Exc. 10 Cm In Width And Using Plain Cement Concrete Type C-1, 1:3:6 (20Mm Graded Agg) And Setting In Cement Mortar 1:6 Complete All As Specified And Directed. , Demolition Of Reinforced Cement Concrete Of Any Description And In Any Position Not Otherwise Specifically Provided For. , M&L For Reinforced Cement Concrete Type B1 1:2:4 Using 20Mm Graded Aggragate In Slabs Supported On Walls, Beams And Columns In Floors, Roofs, Landings, Balconies, Canopies, Chajjas, Deck Slabs And In Shelves And The Like Complete All Specified And Directed , M&L Tmt Bars 10 Mm Dia., And Over Cut To Length, Bent To Shape Required, Including Cranking, Bending Spirally For Hooping For Columns, Hooking Ends And Binding With Mild Steel Wire (Annealed) Not Less Than 0.9 Mm Dia., Or Securing With Clips Qual Complete All Specified And Directed , M&L For Mils Steel Tmt Bars 05Mm Dia And Over, Upto And Including 10 Mm Dia In Stirrups, Spaces And Binders All As Specified And Directed.. , Use And Waste Of Flat Fair Finished Formwork To Soffits Of Suspended Slabs Such As Roof Slabs, Floor Slabs, Landings And Similar Work ; Not Exceeding 200Mm Thick (Horizontal Or Sloping) As Specified , Taking Down Cement Plaster On Brick, Concrete Block Wall Or Stone Walls, Etc., Including Raking Out Joints, Hacking For Key, Scrubbing Down With Water, Etc. Complete All As Specified And Directed. , M & L 10 Mm Thick Rendering In Cement Mortar 1:6 On Brick Or Concrete Surfaces Finished Even & Smooth Without Using Extra Cement Complete All As Specified And Directed. , M & L For 15 Mm Thick Plaster In Cement Mortar 1:4 On Brick Or Concrete Surfaces Finished Even & Smooth Without Using Extra Cement Complete All As Specified And Directed. , Material And Labour For Preparation Of Newly Plastered Surfaces Of Walls And Applying Two Coats Of Distemper Oil Emulsion Over A Coat Of Alkali Resistant Primer. Complete All As Specified And Directed. , Material And Labour Preparing Newly Plastered Wall Surfaces And Applying Two Coats Of Cement Base Paint On Wall Surfaces Over One Coat Of Alkali Resistant Primer Complete All As Specified And Directed. , Dismantling Of Wall And Ceiling Board Or Insulation Boards/Slabs/Blanckets/Any Thickness Including Cover Fillets Complete All As Specified And Directed. , S&F 6 Mm Thick Ply Wood, Grade Bwr, Type Bb, Fixed With Nails To Timber Frame Work On Wall Surfaces Complete All As Specified And Directed. , S&F 4 Mm Thick Ply Wood, Grade Bwr, Type Bb, Fixed With Nails To Timber Frame Work On Ceiling Surfaces Complete All As Specified And Directed. , M & L For 50 Mm Thick Ii Nd Class Hard Wood Clean Sawn Boarding With Butt Joints Fixed With Nails In Any Situation Complete All As Specified And Directed. , M & L For 2 Nd Class Hard Wood Plain Fillets, Square, Rectangular Or Triangular In Section,Wrought, Secured With Nails Or Brads, Sectional Area Exc 3 But N.Exc 6 Sq.Cm. Complete All As Specified And Directed. , M&L For Preparation Of New Wooden Surfaces Of Any Description, Not Other Wise Described, Over 10Cm Width Or Girth And Applying Two Coats Of Synthetic Enamel Paint Over A Coat Of Pink Primer Complete All As Specified And Directed. , Supply And Fix 600Mmx600mmx4mm Thick ‘E Board Classic (Make-Everest Industries Ltd) As In False Ceiling Including Supply And Fixing Gi ‘Tee Grid Frame Work Made Of Special Section Of M.S Galvanized Sheet 0.30Mm Thick , Bottom Portion Painted With Cellular Nitro Painting, Warping The Suspending Wire Around The Existing Wooden/Steel Purlin /Rafter For Suspending Grid Frame Work Of Size 605Mmx605mm Suspended With 4 Mm Dia Gi Wire @ 1200Mm C/C On Main Tee And Fixed To T-Grid With The Help Of Level Clip Or As Per Manufacturer Direction. The Section Consisting Of Main Tee 37Mmx24mmx0.60Mm, Cross Runner Tee 37Mmx24mmx0.60Mm And Perimeter Angle Of 24Mmx24mmx0.50Mm Thick. Perimeter Angle To Be Fixed To Wall With Gi Screw Of 40Mm Long @ 450 Mm C/C Along The Perimeter Of Wall Including Applying Two Coats Of Distemper Oil Emulsion Complete All As Specified And Directed , M & F For Solid Pvc Wall Lining Consisting Of 5Mm Thick Plain Colour Pvc Sheet Inclusive Of Solvent Cement And Fixing At Site On Pvc Frame As Per Specifications And Drawing Complete All As Specified And Directed. , S&F 5Mm Thick Pvc Sheet Fillet Of Width 35Mm For Wall Paneling Inclusive Of Fixing On To Wall To Make Pvc Frame As Per Specification And Drawing Complete All As Specified And Directed. , Taking Down Chowkats Or Frames With Shutters (Without Taking Off Shutters From The Frames) Area Exceeding 1.50 Sqm But Not Exc 4 Sqm. , Taking Down Chowkats Or Frames With Shutters (Without Taking Off Shutters From The Frames) Area Not Exceeding 1.50 Sqm , S & F 2Nd Class Hard Wood Plain Solid Straight Chowkats And Frames, Wrought, Framed Rebated On The Solid Rounded Or Chamfered, Put Together With Glue Pinned At Joints Complete All As Specified And Directed. , S&F 30Mm Flush Shutters, Solid Core Construction With Particle Board Core And Plywood Face Panels, Commercial Type On Both Side And Both Face Is Covered With Decorative Face Veneer With Lipping/Frame Tp Match All As Completed And Specified As Directed. , S & F 30Mm Thick 2Nd Class Hard Wood Glazed And Skeleton Shutters Open Rebated And Prepared To Receive Glass, Gauze Etc But Divided Into Squares, Edges Of Framing Plain, Chamfered Or Rounded, Fitted With Cut And Mitred Beads For Securing Glass, Etc.; Sizes Of Me-Mbers Of Shutters As Specified In Ssr Part I, Section 8, Clause 8.24 (A); Supplied And Fitted To Chowkats Complete All As Specified And As Directed , S&F Solid Pvc Door Frame Of Size 50Mm X 47Mm Made Out Of 5Mm Plain Colour Pvc Sheet Reinforced With M.S. Square Tube, Suppling & Fixing In Opening As Per Specification & Drawing Complete All As Specified And Directed. , S&F Factory Made Solid Panel Pvc Door Shutter 30 Mm Thick (Style) Consisting Of Frame Made Out Of M.S. Tubes For Top & Bottom Rails. M.S. Frame Shall Be Covered With Heat Moulded Plain Colour Pvc ‘C Channel Having A Pvc Sheet Strip Of 20Mm Width Tuck Inside With Solvent Cement For Stiles And Plain Colour Pvc Sheets For Top Rail, Lock Rail & Bottom Rail On Either Side & As Gap Insert For Top Rail & Bottom Rail; Panelling Of Lain Colour Pvc Sheet To Be Fitted In The M.S. Frame Welded / Sealed To The Stiles & Rails With Suitable Pvc Sheet Beading, And Joined Together With Solvent Cement, Suppling & Fixing In The Frame At Site As Per Specification & Drawing Complete All As Specified And Directed. , S&F Ms Window Guard Bars, Window Frames Etc Articles Confirming To Fe 410-0 Or Fe 310-0. , S & F 100Mm Size Mild Steel Butt Hinges Medium Weight Cold Rolled And Fixed. , S & F 75Mm Size Mild Steel Butt Hinges Medium Weight Cold Rolled And Fixed. , S& F Aluminium Anodised Barrel Tower Bolts 150Mm Long Of Extruded Section And Fixed , S& F Aluminium Anodised Barrel Tower Bolts 100Mm Long Of Extruded Section And Fixed , S & F 150Mm Size Extruded Aluminium Alloy Handles, Fabricated Type Anodised , S & F 100Mm Size Extruded Aluminium Alloy Handles, Fabricated Type Anodised , S & F Aluminium Alloy, Anodised, Sliding Door Bolts 300Mm Size With Hasp, Staple (Bolt Type) And Fixing Clips Of Sheets, Cast Or Extruded Sections And Fixing Bolts And Sliding Bolts Of Extruded Section Or Cast Aluminium Alloy And Fixed , S&F In Repair Pre Coated Mild Steel Floor Door Stopper ,Tongue Anodized 140Mm Length Including Vulcanised Rubber Piece Complete All As Specified And Directed. , S&F In Repair Pvc Coated 25Mm Dia Mild Steel Chromium Plated Curtain Rod Of Medium Weight And Including Fixing Brackets, Finals And Decorative End Supports Etc Complete All As Directed , M&L For Power Coated Anodised Aluminium Frame For Doors, Windows, Ventilatores With One Or More Rebated Including Joiing Cleat For Fixing Etc Complete All As Specified And Direcyed , S & F Anodised Aluminium Window And Ventilator Shutters, Fixed Type Without Sash Barsaluminium Section Weighing 0.55 Kg/M Including Necessary Joining Cleats, Glzing Clips,Rubber Packing,Anodised Aluminium Snap Beading,Screws Etc And Power Coating Of Any Colour(Thickness Of Powder Coating Not Less Than 50 Micron.) Complete All As Specified. , M & L For 4.80 Mm Sheet Glass, Ordinary Quality And Glazing With Aluminium Clip And Beading In Square Exc 0.5 Sq. M In Each Panel Complete All As Specified And Directed. , S & F Gi Steel Wire Cloth, 0.56Mm Nominal Dia Of Wire And Average Width Of Aperture 1.18Mm Etc All As Specified. , Hacking Out Old Broken Glass (Any Thickness, Size Quality Or Description) From Metal Frame Including Punching Or Drilling Out Old Glazing Pins/Spring Clips And Providing And Fixing New Ones. , S&F Sheet Glass 3Mm Thick Ordinary Quality And Glazing With Oil Putty In Squares N Exc 0.50 Sqm In Each Panel Complete All As Specified And Directed. , S&F 3Mm Thick Figured Glass, Pin Head Glazing With Oil Putty In Squares N Exc 0.50 Sqm In Each Panel Complete All As Specified And Directed. , Dismatling Of Mild Steel Work Any Description , M&L For Roof Trusses (Framed), Trussed, Purlins, Crane Gantries, Rails And Fastenings And Heavy Bracket Framing (Beam, Tee, Angle, Channel Or Flat Sections) Including Distance Pieces, Cleats Etc Conforming To Fe 290 (Gde E-165) Complete All As Specified And Directed. , M & L For Preparation Of New Or Previously Untreated Steel Surface And Applying Two Coat Of Synthetic Enamel Paint Over A Coat Of Red Oxide Primer To Steel And Iron Surfaces Of Any Description Over 10 Cm In Width Or Girth Not Otherwise Described Including Preparation Of New Steel Surfaces Complete All As Specified And Directed. , Dismantling Of Ci Soil, Rain Water Pipes, Cast And Vent Pipes Of Any Dia, Any Pattern Including All Fittings. , S&F Pvc (Swr) Pipes Single Socketed 110Mm Dia In Any Length With Rubber Ring Joints Fixed To Walls , S&F In Rep Pvc (Swr) Bends Any Radius, Bend 110Mm Dia With Access Door , S&F Pvc (Swr) Pipes 75 Mm Bore Single Socketed, In Any Length With Rubber Ring Joints, Laid In Trenches,Wall Or In Floors. , S&F In Repair Pvc Bends Any Radius 75Mm Bore , S&F In Rep Pvc (Swr) Floor Trap, 75Mm Dia Outlet, Plain With Grating Incl Jointing With Solvent Cement. , S&F In Repair Grating Doom 125Mm Dia With And Without Wast Hole Ptmt (Minimum Weight 40 Grms) , S&F In Repair Grating Doom 100Mm Dia With And Without Wast Hole Ptmt (Minimum Weight 40 Grms) , S&F In Repair 32Mm Pvc Waste Pipe For Kitchen Sink ,Whb Complete All As Specified And Directed. , S&F In Repair Pvc (Swr) Wc Connector 110Mm Dia Complete All As Specified And Directed. , S&F In Repair Vitreous China Squatting Pan Orissa Pattern Size 580 X440 Mm White With Integral Foot Rest Complete All As Specified And Directed. , S7f In Repairs 10 Ltrs Capacity Pvc Valveless Syphonic Action Type Flushing Cistern Low Level White With Inlet Ball Valve, Float, Chain And Pull And Brackets Etc Complete All As Specified And Directed. , S & F In Repair Pvc Connection 15Mm Dia 450 Mm Long With Brass Check Nuts And Washers Complete All As Specified And Directed. , S&F In Repair Vitreous China Wash Down Water Closet Pan Of Pedestal Pattern, White With P Or S Traps, Including Connecting To Trap And To Flushing Pipe Etc Complete All As Specified. , S&F In Repair Vitreous China Wash Hand Basin White Flat Back Of Size 550Mmx400 Mm Including Cutting For And Pinning In End Of Brackets,32 Mm Waste Fittings,Brass Chromium Plated For Glazed Ware Sinks,Basins Etc.With Long Screwed Shanks And Fly Nuts Flange End Bedded In Red Lead Cement And Other End Fixed.And Flush Pipe Of Polytethylene Of Low Or High Density Or Pvc 32 Mm Dia Complete All As Specified And Directed. , S&F In Repair Sinks Made Of Stainless Steel With Drainage Board 1 Mm Thick Kitchen Or Laboratory With Plugs, Washers And Wastes; Including Bedding In Cement Mortar On To Drarf Wall Or Including Fixing Cantilever Brackets And Connecting Union To Pipe, Overall Size 495Mm X 420Mm Bowl Size 410Mm X 330Mm X160mm Complete All As Specified And Directed. , S&F Vitreous China Urinals, Bowl Type 465X355x265 Mm White, Providing & Fixing Plugs, Bedding Urinal Against Wall In Cement Mortar 1:2, Securing Urinal To Plugs With And Including 60Mm Long Brass Screws, Pointing Around Urinal Back In Cement; Fixing Automatic Flushing Cistern With Brackets, Flush Pipe, Grating And Union For Discharge Pipe Complete All As Specified And Directed. , S & F In Repair Plastic Water Closet Seat Cover, White Closed Pattern With Flat Bottom, And Cover And Mild Steel Chromium Plated Or Aluminised Hinging Device Complete All As Specified And Directed. , S&F In Repair For Health Faucet (Abs Body) Mild Steel Chromium Plated Suitable For 15 Mm Dia Pipe With 1.25 Metre Long Flexible Tube And Abs Wall Hook Including Making Connections And Fixed In Position Complete In All Respect As Specified , S&F In Repairs Of Waste Fittings 32 Mm Dia, Brass, Cp For Glazed Ware Sink, Basins, Etc. With Long Screwed Shanks And Fly-Nuts, Flange End Bedded In Red Lead Cement And Other End Fixed Complete All As Specified And Directed. , S&F In Repair Cp Towel Ring Of Ptmt Fixed With Chromium Plated Brass Screws (Min Wt 90 Gms) , S&F In Repair Soap Dish, Any Type, Fiexd To Plugs With Chromium Plated Brass Screws , S&F Cp Towel Rail 600Mm Long Of Ptmt Fixed With Chromium Plated Brass Screws (Min Wt 190 Gms) , S & F In Repair Looking Mirror 600 Mm X 450 Mm Bevelled Edge Mirror Or Selected Quality Glass, Mounted On 6 Mm Thick Ac Building Board Or Commercial Plywood And Fixed To Wooden Plugs With Chromium Plated Brass Screws And Cup Washers Complete All As Specified And Directed. , Dismantling Of Water Tanks Exc 250 Ltrs & N. Exc 500 Ltrs Capacity And Removing To Store. , Dismantling Of Water Tanks Exc 500 Ltrs & N. Exc1000 Ltrs Capacity And Removing To Store. , S&F Pvc Water Storage Tanks Of 500 Ltrs Capacity Rotational Moulded (Multi Layered Cylindrical Vertical With Closed Top) Hoisted And Fixed In Position All As Specified And Directed. , S&F Pvc Water Storage Tanks Of 1000 Ltrs Capacity Rotational Moulded (Multi Layered Cylindrical Vertical With Closed Top) Hoisted And Fixed In Position All As Specified And Directed. , S & F In Repairs Fancy Type 15Mm Dia Bib Tap, Cast Copper Alloy With Crutch Or Butterfly Handle, Screwed Down For Iron Pipe Or For Brass Ferrule Complete All As Specifed. , S & F In Repair 20Mm Ball Brass Valves, High Pressure, With Polyethene Float And Flynut Complete Screwed For Iron Pipe Of 20Mm Dia All As Specified. , S&F In Repair 20Mm Gun Metal Globe Or Gate Valve With Iron Wheel Head, Screwed Both Ends For 20 Mm Dia Of Pipe And Fixed Complete All As Specified And Directed. , S & F In Repair Chromium Plated 15Mm Dia Stop Cock Cast Copper Alloy With Crutch Or Butterfly Handle, Screwed Down For Iron Pipe Or For Brass Ferrule Complete All As Specified , Supply And Fix In Rep 15Mm Pillar Taps , Cast Copper Alloy, With Capstan Heads, Chromium Plated, Screwed Down High Pressure, With Or Without Lettered Hot Or Cold With Long Screwed Shanks And Fly-Nuts, Screwed For Iron Pipe And Fixed Complete All As Specified And Directed. , S&F In Repair 15Mm Brass Cp Mixer For Mixing Hot And Cold Water (Wall Mixer) Screwed Down For Iron Pipe Andd Fixed In Repairs For Bath Shower And Kichen Sink With Complete All As Specified And Directed. , S&F In Repair 15 Mm Brass Cp Basin Mixer Unit With All Fittings Required Complete All As Specified And Directed. , S& F In Repair Sheet Glass Shelf Assembly Consisting Of 5.5Mm Thick Sheet Glass Shelf 12Cm Wide With Chromium Plated Bracket Guard And Railing 60Cm Long Complete All As Specified And Directed. , S& F In Repair Chromium Plated Shower Roses With Or Without Swivel Joints, Any Size, Including Fixing To Steel Pipe Or Union Complete All As Specified And Directed. , Taking Up Or Down 15 Mm Bore Steel Water Tubing And Connections Including Clfor Refixing Or Removal To Store , S&F 15Mm Bore Steel Water Tubes, Medium Grade, Galvanised With All Fittings And Fixed Complete To Walls/Ceilings Or Laid In Trenches Complete All As Specified And Directed. , Taking Up Or Down 20 Mm Bore Steel Water Tubing And Connections Including Cleaning Or Refixing Or Removal To Store , S&F 20 Mm Bore Steel Water Tubes, Medium Grade, Galvanised With All Fittings And Fixed Complete To Walls/Ceilings Or Laid In Trenches. , Supply & Fixing In Repair 3-Layer Pp-R Polypropylene Random Copolymer) Concealed Pipes Of 20 Mm Outer Dia Sdr 7.4 (Pn16) Uv Stabilized And Antimicrobial Fusion Welded Having Thermal Stability For Hot & Cold Water Supply Including All Pp-R Plain & Brass Threaded Polypropylene Random Fittings Fixed Complete To Walls, Ceilings Or In Floors Etc. With All Fittings And Fixed Complete To Wall And Ceiling Or Laid In Floors And Making Connection With Old Gi Tube/Ppr Pipe Using Suitable Section Complete Leakproof All As Specified And As Directed. , Supply & Fixing In Repair 3-Layer Pp-R Polypropylene Random Copolymer) Concealed Pipes Of 16 Mm Outer Dia Sdr 7.4 (Pn16) Uv Stabilized And Antimicrobial Fusion Welded Having Thermal Stability For Hot & Cold Water Supply Including All Pp-R Plain & Brass Threaded Polypropylene Random Fittings Fixed Complete To Walls, Ceilings Or In Floors Etc. With All Fittings And Fixed Complete To Wall And Ceiling Or Laid In Floors And Making Connection With Old Gi Tube/Ppr Pipe Using Suitable Section Complete Leakproof All As Specified And As Directed. , M & L For 100 Mm Thick Cement Concrete Type D- 2,1:4:8 (40Mm Graded Aggregate) As In Sub Base Complete All As Specified And Directed. , M & L Providing And Laying 60Mm Thick Factorymade Chamfered Edge Cement Concrete Paver Block Of M-35 Grade With Approved Colour,Design & Pattern As In Footparth, Parks,Lawns, Drive Ways Or Light Traffic Parking Etc.,Of Required Strength, Thickness & Size/Shape, Made By Table Vibratory Method Usingpu Mould, Laid In Required Colour & Pattern Over And Including 50Mm Thick Compactedbed Of Fine Sand, Compacting And Proper Embedding/ Laying Of Inter Locking Paverblocks Into The Sand Bedding Layer Through Vibratory Compaction By Using Plate Vibrator, Filling The Joints With Sand And Cutting Of Paver Blocks As Per Required Sizeand Pattern, Finishing And Sweeping Extra Sand Complete All As Specified . , M&L Chequered Cement Concrete Tiles 20Cmx20cmx25mm Thick With Grey Cement And Pigment, Set Jointed And Pointed In Neat Cement Slurry In Floors Completed All As Specified And Directed By Engr-In-Charge. , Disconnecting Existing Water Tanks Of Capacity Exc 250 Ltrs But N Exc 500 Ltrs, Setting Aside (Or Lowering If Required) For Repairs, Cleaning, Etc. And Hoisting If Required Reconnecting And Re-Fixing In Position Incl Cleaning And Removing All Scale And Dirt Etc, From Tanks And From Mouths Of Circulating Pipes Etc Complete All As Specified And Directed. , Disconnecting Existing Water Tanks Of Capacity Exc 500 Ltrs But N Exc 1000 Ltrs, Setting Aside (Or Lowering If Required) For Repairs, Cleaning, Etc. And Hoisting If Required Reconnecting And Re-Fixing In Position Incl Cleaning And Removing All Scale And Dirt Etc, From Tanks And From Mouths Of Circulating Pipes Etc Complete All As Specified And Directed.
Contract Date: Jul 02, 2026 Contract Value : 41.50 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 6
Arunachal Pradesh View Result →
50.
Heavy Industries and Public Enterprises #11159621 Technical Bid
Tender For Renovation Of Training Centre At Kcm Plant; 1 Providing & Fixing Precoated galvanised iron profile /Trapezoidal prifile sheets (Size,Shape and pitch of corrugation as approved by Engineer-In-Charge)manufactured out of 0.50 mm (0.05%)TCT with zinc coating 120 grams per sqm as per IS:277, in 240 mpa steel grade, 5-7 microns epoxy primer on both sides of the sheet and polyster top coating 15-18 micron. Sheets should have protective guard film of 25 microns minimum to avoid scratches during transportation. The sheet shall be fixed using self drilling/self tapping screws size(5.50-8 x55 mm) with EPDM seal, complete upto any pitch in Horizontal/Vertical or curved surfaces, excluding the cost of purlins,rafters & trussesand including cutting to size and shape whenever required. 2 Providing and fiixing precoated galvanised steel sheetsroofing accessories 0.50 mm(+0.50%) total coated thickness , Zinc coating 120 grams per sqm as per IS 277, 240 mpa steel grade , 5-7 microns epoxy primer on both sides of the sheet and polyster top coat 15-18 microns using self drilling/self tapping screws of size ( 5.5-8 x 55 mm with EPDM seal) complete.(A) Ridges plain(500-600 mm). 3 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorptions less than 0.08% andconformingtoIS:15622ofapprovedmakeinallcoloursand shades, laidon 20mm thick cement mortar 1:4 (1 cement: 4coarse sand)includinggroutingthejointswithwhitecementandmatching pigments etc., complete.Size of Tile 60x60 cm 4 Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main T runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross T of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main T at 600 mm center to center to form a grid of 1200x600 mm and secondary cross T of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main T runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-Charge12.5 mm thick fully Perforated Gypsum Board tile made from plasterboard having glass fibre conforming to IS: 2095 part I, of size 595x595 mm, having perforation of 9.7x9.7 mm at 19.4 mm c/c with center borders of 48 mm and the side borders of 30 mm, backed with non woven tissue on the back side, having an NRC ( Noise Reduction Coefficient) of 0.79, with 50 mm resin bonded glass wool backing. 5 Providing and fixing aluminium work for doors, ventilators and partitions with extruded built up standard tubular sections / appropriate Z sections and other sections of approved mark confirming to IS : 733 and IS : 1285 , fixed with dash fastners of required dia and size , including necessary fillings up of gaps at junctions at top, bottom and sides with required EPDM Rubber / Neoprene gasket etc. Aliminium sections shall be smooth rust free straight metred and jointed mechanically wherever required including clit angle aliminium snap beading for glazing / panneling C.P Brass/ stainless steel screws all complete as per architectural drawing and the directions of Engineering In Charge (Glazing ,panneling dash fasteners to be paid for separately). For shutters of doors , windows and ventilators including providing and fixing hinge/pivots and making provision for fixing of fittings wherever required including the cost of EPDM Rubber / Neoprene gasket required (fitting shall be paid for separately) Power coated aluminium (Minimum thickness of powder coating 50 micron). 6 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber /neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5 mm thickness (weight not less than 12.50 kg/ sqm) 7 Repairs to plaster of thickness 12mm to 20mm in patches of area 2.5 sq. meters and under including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete including disposal of rubbish to the dumping ground within 50metres lead :With cement mortar 1:4 (1 cement : 4 fine sand) 8 DISMANTLING WOODEN PARTITION WALL INCLUDING FRAME WORK, COMMERCIAL PLY, DOOR SHUTTER WITH BUTT HINGES, WOODEN BEADING ETC. COMPLETE, AS PER DIRECTION OF ENGINEER IN- CHARGE. LABOUR RATE ONLY 9 REINFORCED CEMENT CONCRETE WORK IN BEAMS, SUSPENDED FLOORS, ROOFS HAVING SLOPE UPTO 15 DEGREE, LANDINGS , BALCONIES, SHELVES, CHAJJAS, LINTELS, BANDS, PLAIN WINDOW SILLS, STAIRCASES AND SPIRAL STAIR CASES UPTO TO FLOOR FIVE LEVEL EXCLUDING THE COST OF CENTERING, SHUTTING AND REINFORCEMENT WITH 1:2:4 ( 1 CEMENT : 2 COARSE SAND : 4 GRADED STONE AGGREGATE 20 MM NOMINAL SIZE). 10 ReinforcementforR.C.C. workincludingstraightening,cutting, bending, placing in position and binding all complete. Cold twisted bars 11 Takingoutdoors,windowsandclerestorywindowshutters(steelor wood) including stacking within 50 metres lead: Of area 3 sq. metres and below 12 Dismantling roofing including ridges, hips valleys andgutters etc., and stacking the material within 50 metres lead of: Asbestos sheet 13 Finishing walls with water proofing cement paint of required shade : new work(two or more coats applied @3.84kg/10 sqm) 14 PROVIDING AND APPLYING WHITE CEMENT BASED PUTTY OF AVERAGE THICKNESS 1 M.M. OF APPROVED BRAND AND MANUFACTURER OVER THE PLASTERED WALL SURFACE TO PREPARE THE SURFACE EVEN AND SMOOTH COMPLETE. 15 WALL PAINTING WITH ACRYLIC EMULSION PAINT OF APPROVED BRAND 16 Paintingwithsyntheticenamelpaintofapprovedbrandand manufacture to give an even shade :Two or more coats on new work 17 Centeringandshutteringincludingstrutting,proppingetc.and removal of form for : Suspendedfloors,roofs,landings,balconiesand access platform. 18 Providing and fixing double action hydraulic floor spring of approved brand and manufacture IS : 6315 marked for doors including cost of cutting floors as required embeding in floors and cover plate with brass pivot and single piece M.S. Sheet outer box with slide plate etc With Brass cover plate 19 Demolishingcementconcretemanually/bymechanicalmeans including disposal of material within 50 metres lead as per direction of Engineer - in - charge.1:3:6 or richer mix 20 DemolishingR.C.C.workmanually/bymechanicalmeansincluding stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge. 21 Carriage of material by mechanical transport including loading, unloading and stacking:Lime, moorum, building rubbish:Lead 1 KM. 22 Providingandfixingonwall faceunplasticised RigidPVCrainwater pipes conforming to IS : 13592 Type A including jointing with seal ring conformingtoIS: 5382 leaving 10 mm gap for thermal expansion.(i) Single socketed pipes. 110 mm diameter 23 Providing and fixing on wall face unplasticised - PVC moulded fittings/Accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS :5382 leaving 10 mm gap for thermal expansion. Shoe (Plain)- 110 mm 24 Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 110 MM 25 Providing and fixing on wall face unplasticised - PVC moulded fittings/Accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS :5382 leaving 10 mm gap for thermal expansion. Bend 87.5°- 75 mm bend 26 PROVIDING AND FIXING BRIGHT FINISHED BRASS 100 MM. MORTICE LATCH AND LOCK WITH 6 LEVERS AND A PAIR OF LEVER HANDLES WITH NECESSARY SCREWS ETC. COMPLETE.(BEST MAKE OF APPROVED QUALITY) 27 REMOVING DRY OR OIL BOUND DISTEMPER BY SCRAPPING, SAND PAPERING AND PREPARING THE SURFACE SMOOTH INCLUDING NECESSARY REPAIRS TO SCRATDHES ETC. COMPLETE. 28 Providing and fixing anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer-in-charge. (Only weight of grill to be measured for payment). 29 PROVIDING AND FIXING 6 MM DIA. G.I. LEVEL ADJUSTING HANGERS (UPTO 1200 MM LENGTH), FIXED TO ROOF SLABS BY MEANS OF CEILING 30 Structural steel work riveted bolted or welded in built up section,trusses and framed work including cutting,hoisting,fixing in position and applying a priming coat of approved steel primer all complete.
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 5
TenderDetail
Loading tenders