}

Medical Related Equipment and Supplies, Medical Equipments, Medical Equipment, Dr.RMLIMS, Lucknow-Uttar Pradesh

Institute Of Medical Sciences-IOMS has published Medical Related Equipment and Supplies, Medical Equipments, Medical Equipment. Submission Date for this Tender is 03-12-2018. Medical Equipment Tenders in Dr.RMLIMS, Lucknow Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

18216168
Medical Related Equipment and Supplies, Medical Equipments, Medical Equipment
Open Tender
Indian
Uttar Pradesh
Dr.RMLIMS, Lucknow
03-12-2018

Tender Details

Re Tender For The Procurement Of Hand Instruments For Percutaneous Endoscope For The Department Of Anaesthesiology :- Instruments For Trans / Extraforaminal Percutaneous Spine Endoscope Spinal Cannula Set Should Be 10 Pieces, Sterile, Wl 150 Mm, Ø 1.25 Mm Dilator Should Have Dia 6.9 Mm Working Sleeve With Bevel Should Be Dia 8.0 Mm, And Wl 185 Mm Irrigation Adapter Should Have Dia 8.0 Mm Extension Sleeve Should Have 8.0 Mm Micro-Punch Should Have 2.5 Mm, Curved, Wl 360 Mm For 4 Mm Working Channel Micro-Punch Should Have Dia 2.5 Mm, Wl 360 Mm Micro-Rongeur With Long Jaws Should Have Dia 2.5 Mm, Wl 360 Mm Micro-Rongeur Should Have Dia 2.5 Mm, Curved, Wl 360 Mm For 4 Mm Working Channel Nucleus Grasping Forceps Should Have 3.0 Mm, Wl 360 Mm Nucleus Grasping Forceps Should Have 4.0 Mm, Wl 360 Mm Tube Shaft Punch Should Have 4.0 Mm, Wl 360 Mm Atraumatic Dissector Should Have 2.5 Mm, Wl 350 Mm Atraumatic Dissecto Should Have Dia 4.0 Mm, Wl 350 Mm A. Accessories X-Tractor Mallet Hand Instruments For Percutaneous Spine Endoiscope Interlaminar Dilator Should Have Dia 6.9 Mm. Working Sleeve With Bevel Should Have 8.0 Mm, Wl 120 Mm With Irrigation Adapter, Dia 8.0 Mm Micro-Punch Should Have Dia 2.5 Mm, Wl 290 Mm Micro-Punch Should Have Dia 2.5 Mm, Curved, Wl 360 Mm Micro-Rongeur Should Have 2.5 Mm, Wl 290 Mm Rongeur Dia 3.0 Mm, Wl 290 Mm And Rongeur Dia 4.0 Mm, Wl 290 Mm Tube Shaft Punch Should Have Dia 4.0 Mm, Wl 290 Mm Atraumatic Dissector Should Have 2.5 Mm, Wl 350 Mm Atraumatic Dissector Should Have 4.0 Mm, Wl 350 Mm Hand Instruments For Percutaneous Spine Endoscope- Stenotic Dilator Outer Dia 9.4 Mm, Cannulated, For Working Sleeve Od 10.5 Mm Step-Dilator Set Comprising O Dilator Od 3.9 Mm, Cannulated, For Working Sleeve O Dilator Od 5.9 Mm, For Working Sleeve Or Dilator Od 7.0 Mm O Dilator Od 6.9 Mm, For Working Sleeve Or Dilator Od 9.5 Mm

Key Value

Document Fees
Refer document
EMD
INR 10500.0 /-
Tender Value
INR 10 Lakhs /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail