Indian Tenders

Tender Notice

TDR 55934259
Tendering Authority Banaras Hindu University
Tender No UWD/2025/11062026-1
Tender ID 2026_BHU_912655_1
Tender Brief Tender For Construction Of Attached Toilet, Wall Penelling In Deans Chamber, And Provision Of Vitrified Floor Tiles In Teachers Chamber-Faculty Of Svdv Building, Bhu.
City Varanasi
State Uttar Pradesh
Document Fees INR 500 /-
EMD INR 31065.0 /-
Tender Value INR 15.53 Lakhs /-
Tender Type Tender
Bidding Type Open Tender
Competition Type Indian

Tender Details

Tender for Construction Of Attached Toilet, Wall Penelling In Deans Chamber, And Provision Of Vitrified Floor Tiles In Teachers Chamber-Faculty Of Svdv Building, Bhu.

Key Dates

Publish Date 11-06-2026
Last Date of Bid Submission 18-06-2026
Tender Opening Date 22-06-2026

Contact Information

Company Name Banaras Hindu University
Contact Person PIC , UWD, BHU
Address Office of PIC , UWD, BHU

BOQ Items

Name of Work:- Construction of Attached Toilet, Wall Penelling in Deans Chamber, and Provision of Vitrified Floor Tiles in Teachers Chamber-Faculty of SVDV Building, BHU.
Sl. No. Item Description
1Civil work
2Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.Double charge vitrified tile polished finish of size Size of Tile 600 x 600 mm (11.41A.1.1)
3Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS: 15622, of approved brand & manufacturer, in all colours and shade, in skirting, riser of steps, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS: 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately). Size of Tile 600x600 mm (11.47.2)
4Fixing glazed/ Ceramic/ Vitrified floor tiles with cement based high polymer modified quick-set tile adhesive (Water based) conforming to IS: 15477, in average 3mm thickness.(11.43)
5Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. In cement mortar (15.7.4)
6Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. (15.56)
7Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) (15.2.1)
8Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. : All kinds of soil. (2.8.1)
9Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand) (6.1.2)
10Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand) (6.4.2)
11Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) (4.1.8)
12Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) (4.1.3)
13Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). (5.3)
14Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platform (5.9.3)
1512 mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand) (13.4.2)
166 mm cement plaster of mix : 1:3 (1 cement : 3 fine sand) (13.16.1)
17Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete. (11.37)
18Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. (8.31)
19Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required : Single half stall urinal with 5 litre P.V.C. automatic flushing cistern (17.5.1)
20Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid (17.2.1)
21Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. (17.31)
22Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tap (17.7.4)
23Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc.Internal work - Exposed on wall 15 mm dia nominal bore (18.10.1)
24Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc.External work 25 mm dia nominal bore (18.12.3)
25Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.: 15 mm nominal bore (18.51.1)
26Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. 15 mm nominal bore (18.52.1)
27Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) : 25 mm nominal bore (18.46.3)
28Providing and fixing soil, waste and vent pipes : 100 mm dia: Centrifugally cast (spun) iron socket & spigot (S&S) pipe as per IS: 3989 (17.35.1.2)
29Providing and fixing plain bend of required degree. 100 mm dia: Sand cast iron S&S as per IS : 3989 (17.39.1.2)
30Providing and fixing single equal plain junction of required degree : 100x100x100 mm: Sand cast iron S&S as per IS - 3989 (17.44.1.2)
31Providing and fixing terminal guard :100 mm: Sand cast iron S&S as per IS - 3989 (17.56.1.2)
32Providing and fixing collar : 100 mm: Sand cast iron S&S as per IS - 3989 (17.57.1.2)
33Providing lead caulked joints to sand cast iron/centrifugally cast (spun) iron pipes and fittings of diameter :100 mm (17.58.1)
34Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors : 100 mm inlet and 100 mm outlet Sand cast iron S&S as per IS: 3989 (17.60.1.1)
35Providing and fixing uplasticised PVC connection pipe with brass unions : 45 cm length: 15 mm nominal bore (18.21.2.1)
36Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. Cement mortar 1:4 (1 cement :4 coarse sand) (6.13.2)
37Constructing masonry Chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:1.5:3 mix (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20mm nominal size ) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : With common burnt clay F.P.S.(non modular) bricks of class designation 7.5 (18.33.1)
38Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. (5.22A.6)
39Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. (15.60)
40Deduct for not using 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand) bedding in laying of floor tiles and jointing with grey cement slurry @ 3.3 kg/ sqm. (11.42)
41Providing and fixing 16 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels. Granite stone slab of all colour and texture except black, Cherry/Ruby red Area of slab over 0.50 sqm (NS)
42Providing and fixing upper heavy PVC wall panelling of 5 mm thickness with approved finish and colour, including all necessary accessories (such as trims and corner beads), surface preparation and required consumables (adessives, screws, sealants). The scope includes cutting, fixing, and finishing to ensure a durable and aesthetically pleasing surface. All as per Direction of Engineer-Incharge. The PVC panels shall be termite-proof, water-resistant, and corrosion-resistant ensuring long-lasting performance.Note: - The weight of each panel (size 10’x10”) shall not be less than 2.80kg. (NS)
43Providing and fixing CP brss health faucet with 1.2 meter long flexible tube and wall hook of Cera (code No. F160023CP) / Parryaware make as per direction of Engineer in-charge. (NS)
44Electrical Work
45Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C (1.10.3)
46Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire (1.14.1)
47Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 2 X 4 sq. mm + 1 X 4 sq. mm earth wire (1.14.3)
48Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 2 X 6 sq. mm + 1 X 6 sq. mm earth wire (1.14.4)
49Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6 amps switch (1.24.1)
50Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 A switch (1.24.3)
51Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 3 pin 5/6 A socket outlet (1.24.4)
52Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 6 pin 15/16 A socket outlet (1.24.5)
53Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required (1.26)
54Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required 12 Module (200mmX150mm (1.27.6)
55Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. (1.32)
56Supplying and fixing PVC batten/ angle holder including connections etc. as required (1.58)
57Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required (1.38)
58Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings (1.56)
59Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \\"C\\" curve including connections, painting etc. as required (1.57)
60Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as requiredSingle pole (2.10.1)
61Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earthbar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 8 way , Double door (2.3.2)
62Supplying and drawing following sizes of FRLS PVC insulatedcopper conductor, single core cable in the existing surface/recessed steel/ PVC conduit as required 3 x 1.5 sq. mm (1.17.3)
63Supplying and fixing of following sizes of medium class PVCconduit along with accessories in surface/recess includingcutting the wall and making good the same in case of recessedconduit as required. 20 mm (1.21.1)
64Supplying and fixing of following sizes of medium class PVCconduit along with accessories in surface/recess includingcutting the wall and making good the same in case of recessedconduit as required. 25 mm (1.21.2)
65Supplying and fixing following modular switch/ socket on theexisting modular plate & switch box including connections butexcluding modular plate etc. as required. 5/6 A switch (1.24.1)
66Supplying and fixing two module stepped type electronic fanregulator on the existing modular plate switch box includingconnections but excluding modular plate etc. as required (1.25)
67Supplying and fixing following size/ modules, GI box alongwithmodular base & cover plate for modular switches in recess etc.as required 6 Module (200mmX75mm (1.27.4)
68Supplying and fixing following size/ modules, GI box alongwithmodular base & cover plate for modular switches in recess etc.as required 8 Module (125mmX125mm) (1.27.5)
69LED Batten light (System lumen efficacy ≥105 <120lm/Watt).Powder coated die cast /Extruded aluminiumBody (Thickness > 1.20 mm) 18- 22 Watt (8.9.1)
70Supplying ,Insttalation ,testing and commissioning of 9 watt LED Bulb suitable for B22 holder for 230 volt 50Hz ,single phase AC supply etc complete as required at site. (Make:- Crompton/Havells/Wipro/phillips/Bajaj) (MR)
71Supplying ,Insttalation ,testing and commissioning of 300 mm sweep heavy duty on existing opening with 82/85 watt capacity , 900 rpm speed at 1950 CMH flow rate made in metallic body & blade finish and metallic motor suitable for 230 volt 50Hz ,single phase AC supply with earthing connection including connection with FRLS 3 core wire etc complete as required at site. (Make:-Havells/Orient/ Crompton/Havells/Wipro/phillips) (MR)
72Supplying ,Insttalation ,testing and commissioning of 400 mm sweep wall fan on wall with 50 watt capacity , 1350 rpm speed at 72 CMM air delivery rate made in plastic body & blade and metallic motor suitable for 230 volt 50Hz ,single phase AC supply with earthing connection including suitable size fastener for fixing & connection with FRLS 3 core wire etc complete as required at site. (Make-Havells /Orient/ Crompton/Usha) (MR)
73LED Panel light 2x2 ft. (System lumen efficacy ≥105<120 lm/Watt)Powder Coated CRCA Sheet Body (Thickness >0.50 mm) 40 watt (8.6.11)
74Supplying ,Installation , Testing and commissioning of wall mounted mirror light of 10 watt LED batten light of 2 feet long with minimum lumen output 1000 lumen made of extruded Aluminium housing and shall have polycarbonate diffuser including connection with 1.5 Sq mm FRLS PVC insulated copper conductor single core cable with earthing and suitable for 230 volt 50Hz ,single phase AC supply complete etc as required. . (Make-rompton Model No CCS-100-20-65 HL2-DP-NWHor equivalent specification of Wipro/Havells/Phillips) (MR) Please Enable Macros to View BoQ information

Other Detail

Information Source https://eprocure.gov.in/eprocure/app
Download FileName File Description File Size
Download b166a2d5-6405-45ba-bb48-0d4d62288e40.html Tender Documents 0 KB
Download BOQ_959138.xls Tender Documents 0 KB
Download TD.pdf Tender Documents 0 KB
Download Tendernotice_1.pdf Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.