Indian Tenders

Tender Notice

TDR 55932146
Tendering Authority Public Works Department
Tender No PWD/BLDG/TR/21883/2025_6_1_1/2
Tender ID 2026_PWD_855488_1
Tender Brief Tender For Deposit-Providing Inverter System And Allied Electrical Works In Urban Health And Wellness Centre Nathukallu & Parakadavu (Kattappana)-Providing Inverter System And Allied Electrical Works In Urban Health And Wellness Centre Nathukallu & P
City Kattappana
State Kerala
Document Fees INR 555 /-
EMD INR 4517.0 /-
Tender Value Refer document
Tender Type Tender
Bidding Type Open Tender
Competition Type Indian

Tender Details

Tender for Deposit-Providing Inverter System And Allied Electrical Works In Urban Health And Wellness Centre Nathukallu & Parakadavu (Kattappana)-Providing Inverter System And Allied Electrical Works In Urban Health And Wellness Centre Nathukallu & Parakadavu (Kattappana)-General Electrical Work

Key Dates

Publish Date 11-06-2026
Last Date of Bid Submission 18-06-2026
Tender Opening Date 20-06-2026

Contact Information

Company Name Public Works Department
Contact Person ASSISTANT EXECUTIVE ENGINEER,
Address O/o ASSISTANT EXECUTIVE ENGINEER, PWD ELECTRICAL SUB DIVISION, IDUKKI, PAINAVU P.O, PAINAVU-685603

BOQ Items

Name of Work:- DEPOSIT-Providing Inverter system and allied electrical works in Urban Health and Wellness Centre Nathukallu & Parakadavu (Kattappana)-Providing Inverter system and allied electrical works in Urban Health and Wellness Centre Nathukallu & Parakadavu (Kattappana)-General Electrical Work
Sl. No. Item Description
1Urban Health and Wellness Centre Nathukallu-Electrification
2OD256657/2025-2026:Supply, conveyance, installation, testing and commissioning of 2 KVA sine inverter working by 24 Volt DC supply with battery charging unit with indications ,input voltage 150-270V AC supply , Output voltage 230V +/-3%, 50 Hz +/- 1% and Short circuit,over/under voltage,surge & spike protections including giving connection etc (EXIDE/Amaron or equalent ) with supply and fixing of 2 Nos C10 12V 105 AH fully charged Lead acid Tubular tower Battery with terminal leads for the existing 2 KVA inverter unit (EXIDE/Micortech/Supra or equivalent) including battery and inverter cabinet connected etc as required .
31.17.12:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm
41.17.15:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.6 x 2.5 sq. mm
51.17.21:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm
61.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
71.21.2:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
81.24.3:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch
91.24.5:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet
101.27.2:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)
112.3.3:Supplying and fixing following way, single pole and neutral, sheet steel, MCBdistribution board, 240 volts, on surface/ recess, complete with tinned copperbus bar, neutral bus bar, earth bar, din bar, interconnections, powder paintedincluding earthing etc. as required. (But without MCB/RCCB/Isolator)12 way, Double door
122.10.1:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Single pole
132.11:Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
142.12.1:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
152.14.1:Supplying and fixing following rating, double pole, (single phase and neutral),240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps
165.1:Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt ) as required.
1790.16.1.3:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG)
1890.16.5.3:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG)
19Urban Health and Wellness Centre Parakadavu (Kattappana)-Electrification
20OD256845/2025-2026:Supply, conveyance, installation, testing and commissioning of 2 KVA sine inverter working by 24 Volt DC supply with battery charging unit with indications ,input voltage 150-270V AC supply , Output voltage 230V +/-3%, 50 Hz +/- 1% and Short circuit,over/under voltage,surge & spike protections including giving connection etc (EXIDE/Amaron or equalent ) with supply and fixing of 2 Nos C10 12V 105 AH fully charged Lead acid Tubular tower Battery with terminal leads for the existing 2 KVA inverter unit (EXIDE/Micortech/Supra or equivalent) including battery and inverter cabinet connected etc as required .
211.17.12:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm
221.17.15:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.6 x 2.5 sq. mm
231.17.21:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm
241.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
251.21.2:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
261.24.3:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch
271.24.5:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet
281.27.2:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)
292.3.3:Supplying and fixing following way, single pole and neutral, sheet steel, MCBdistribution board, 240 volts, on surface/ recess, complete with tinned copperbus bar, neutral bus bar, earth bar, din bar, interconnections, powder paintedincluding earthing etc. as required. (But without MCB/RCCB/Isolator)12 way, Double door
302.10.1:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Single pole
312.11:Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
322.12.1:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
332.14.1:Supplying and fixing following rating, double pole, (single phase and neutral),240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps
345.1:Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt ) as required.
3590.16.1.3:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG)
3690.16.5.3:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG) Please Enable Macros to View BoQ information

Other Detail

Information Source https://etenders.kerala.gov.in
Download FileName File Description File Size
Download a61616b7-ce41-4476-9a4f-fbeb4e84314c.html Tender Documents 0 KB
Download BOQ_1445833.xls Tender Documents 0 KB
Download NIT.pdf Tender Documents 0 KB
Download SBD.pdf Tender Documents 0 KB
Download Tendernotice_1.pdf Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.