Indian Tenders

Tender Notice

TDR 55925467
Tendering Authority Public Works Department
Tender No Tender Notice No.20
Tender ID 2026_CEPW_169924_1
Tender Brief Tender For Special Repair And Upgradation Of Olympian Balbir Singh Senior International Hockey Stadium At Mohali ( Electrical Works Only) { Repair Of Street Light & C Us Light,Upgradtion Of Exisiting Sub Station,Lighting Protection System & Desktop,
City Chandigarh
State Chandigarh
Document Fees INR 5000 /-
EMD INR 68528.0 /-
Tender Value INR 34.26 Lakhs /-
Tender Type Tender
Bidding Type Open Tender
Competition Type Indian

Tender Details

Tender for Special Repair And Upgradation Of Olympian Balbir Singh Senior International Hockey Stadium At Mohali ( Electrical Works Only) { Repair Of Street Light & C Us Light,Upgradtion Of Exisiting Sub Station,Lighting Protection System & Desktop, Photocopier Printer Other Accessories}

Key Dates

Publish Date 10-06-2026
Last Date of Bid Submission 20-06-2026
Tender Opening Date 20-06-2026

Contact Information

Company Name Public Works Department
Contact Person Executive Engineer
Address SCO No 35 2nd Floor Sector 17E Chandigarh

BOQ Items

Name of Work:- SPECIAL REPAIR AND UPGRADATION OF OLYMPIAN BALBIR SINGH SENIOR INTERNATIONAL HOCKEY STADIUM AT MOHALI ( ELECTRICAL WORKS ONLY) { REPAIR OF STREET LIGHT & C US LIGHT,UPGRADTION OF EXISITING SUB STATION,LIGHTING PROTECTION SYSTEM & DESKTOP, PHOTOCOPIER PRINTER OTHER ACCESSORIES}
Sl. No. Item Description
1PVC INSULATED FR COPPER CONDUCTOR CABLES:Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:-
2Overall size 1.5sq.mm (Un-sheathed)
3DOUBLE WALLED CORRUGATED (DWC) HDPE PIPES:Supply and erection of Double Walled Corrugated (DWC) HDPE pipe to be laid 1mtr. below ground level including excavation placing the pipe in position and back filling with excavated soil etc. of the required size:-
4Double Walled Corrugated HDPE Pipe 50/ 38mm (Outer/ Inner dia.)
5XLPE INSULATED UN-ARMOURED CABLES (LOOSE):Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed Un-armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid loose in the existing trench or pipe as per PWD General Specifications:-
6Overall size 16sq.mm (4Core) Un-armoured (Loose)
7Supply & erection of 20W LED Bulb B-22 white. Complete in all respect as desire by the Engineer in charge of work at site. The certification and specification of the LED fitting should be as approved by office Advisor Technical Govt. of Punjab vide letter NO. AT2021 GL 1410-1422 Dated 06-05-2021. Beside this the lighting fixtures manufacturer should have in house NABL accredited LAB.
8Supply and erection of LED Street Light 45 watt (including LED driver) with pressure die cast aluminium housing with control gear ( IP 66 protection),THD< 10%, CRI minimum 70, High power LED with mandatory secondary lenses, toughened glass fitting, 4 KV SPD within driver and 10KV external SPD, efficacy of LED fixture minimum 120 lumens per watt, complete in all respects as approved and desired by the Engineer in-charge at site. LED Fittings as per specifications approved by Hon'ble Technical Advisor to CM Punjab vide letter No. AT-2021/GL 1410-1422 Dated 06/05/2021. Beside this the lighting fixtures manufacturer should have in house NABL accredited LAB.
9MINIATURE CIRCUIT BREAKERS:Supply and erection of Miniature Circuit Breaker MCB's for circuit protection against overload and short circuit current fault suitable for 240/ 415 volts 50cycles AC supply with breaking capacity of 10kA, Curve-C and low watt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs:-
10MCB Single Pole 6-32amp. (10kA, Curve-C)
11PAINTING INCLUDING LABOUR AND MATERIAL:Painting of Steel tubular pole with brackets with two coats of aluminium paint (With brush):-
12Overall Length 7 Metre
13Overall Length 8.5 to 9 Metre
14Upgrading of existing Sub Station System:-INDOOR LT PANELS: LT PANELS & MCCB's (MOULDED CASE CIRCUIT BREAKERS): Designing, Supply, Erection, Testing & commissioning of indoor Type LT cubical panel enclosure (dust, vermin and interchangeable modules with facilites for extensions or reduction as per the space or requirments). The Panel shall be suitable for operation at 415+6% Volts, 50HZ, 3 phase 4 wire & earth system. The assembly manufacturer should be ISO approved and CPRI tested for short circuit of (minimum 50kA) as well as IP degree of protection (IP 54/55).SUB LT PANEL (NORMAL):
15LT Panel enclosure having space for 1No. Incomer MCCB 630Amp. and 6Nos. outgoing MCCB's 40amp. to 250amp. (Option: MCCB 200-250amp.= 2Nos. and MCCB's 40-100amp.= 4Nos.) according to the requirement at site (Approx. size 1475 x 1800 x 400mm)
16MCCB's (FOR PANELS & SHEET ENCLOSURE):Supply and erection of Moulded Case Circuit Breaker (Panel mounting Cubical type) in the existing Cubical Panel (confirm to IEC:60947-2) having Ics=100% Icu, 100% neutral with spreader terminal links, Extended rotary handle and relevant PWD general specifications complete with G.I. Bolts, Nuts & Connection on both sides of MCCB with suitable size of thimbles etc
17MCCB Four Pole 63/80/100amp., 415volts, ≥25kA Fixed Magnetic and Adjustable Thermal Setting
18MCCB Four Pole 400amp., 415volts, ≥36kA Microprocessor Based Adjustable Thermal and Magnetic Setting
19MCCB Four Pole 630amp., 415volts, ≥36kA Microprocessor Based Adjustable Thermal and Magnetic Setting
20XLPE INSULATED UN-ARMOURED CABLES (LOOSE):-Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed Un-armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid loose in the existing trench or pipe as per PWD General Specifications:-
21Overall size 400sq.mm (3½ Core) Un-armoured (Loose)
22DOUBLE WALLED CORRUGATED (DWC) HDPE PIPES:Supply and erection of Double Walled Corrugated (DWC) HDPE pipe to be laid 1mtr. below ground level including excavation placing the pipe in position and back filling with excavated soil etc. of the required size:-
23Double walled corrugated (DWC) HDPE pipe120/103.50mm (outer/ inner dia.)
24ON LOAD CHANGEOVER SWITCH (Without Sheet Enclosure):Supply and erection of On Load Change over Switch with advance neutral UNIT (Panel mounting Cubical type) in the existing Cubical Panel Confirms to IS 13947 (Part-3) complete with G.I. Bolts, Nuts & Connections on both sides of switch with suitable size of thimbles as per PWD General Specifications:-
25On Load Change Over Switch Four Pole 400amp., 415volts
26INDOOR LT CABLES, CABLE TRAY & DWC PIPE:CABLE TRAY:Supply and erection of MS perforated cable tray (MS Sheet thickness 2mm) with DA gray paint on the existing surface with the help of MS angle iron support (to be painted with approved paint) of size 50mm x 50mm x 6mm thick to be fixed with fastners/ nut & bolts etc., complete in all respect as desired by the Engineer-in-charge and as per PWD General Specifications:-
27Cable Tray Size 300mm x 50mm x 50mm (2mm thick)
28Supply and erection of heavy duty brass single compression gland for cable end termination duly complete with checknuts etc. including making necessary connections:-
29Brass Gland for Aluminium cable 3/3½/4 Core size 400sq.mm
30Supply and erection of heavy duty aluminium thimbles/lugs for cable end termination duly crimped including making necessary connections completely:-
31Aluminium thimble cable Core size 240sq.mm
32Aluminium thimble cable Core size 400sq.mm
33COPPER EARTHING COPPER EARTHING (Upto 8 metre in Length):Earthing with electrolytic Copper Tape rivetted (with 5Nos. copper rivets)/Steel Nut & bolts (with 4Nos. 32mm long, 8mm thick with washer and double nut) to 30cm x 120cm x 2mm thick copper plate (made cylindrical) burried 4.50 metre (14.76 feet) below ground level in the hole of excavation having bore dia. 125mm and surrounded by salt & charcoal dust mixture (20 kg.) including fixing the Copper Tape recessed in wall and in floor etc., up to 8metre in Length (including bore Length). G.I. pipe 20mm dia. (A-class), 3metre long should be laid in the hole of excavation 1 feet below ground level and having GI Reducer 50mm x 20mm with PVC Cap (For pouring water) fixed on the top level of the pipe. 300mm x 300mm x 300mm deep haudi of First class bricks finished with 1:4 cement plaster and haudi covered with cast iron lid having size 300mm x 300mm (Heavy) around the hole of excavation:-
34Earthing with 20mm x 3mm Copper Tape (upto 8Metre in Length)
35COPPER EARTHING STRIP (As Additional Length):Fixing additional Length of earthing with Copper Tape (On Surface/Flushed) with petty material as required etc.:-
36Additional Length 20mm x 3mm thick Copper Tape
378 SWG COPPER EARTHING :Earthing with 8 SWG (4mm dia.) electrolytic copper wire thimbled (1No. copper thimble with suitable size steel bolt, washers & double nut) with 30cm x 60cm x 2mm thick copper plate (made cylindrical) burried below ground level in the hole of excavation having bore dia. 125mm and surrounded by salt & charcoal dust mixture (20 kg.) including fixing the copper wire run through 20mm dia. G.I. pipe (A-Class) recessed in wall and in floor etc., up to suitable Length in metre (including bore Length). G.I. pipe 20mm dia. (A-class) of suitable Length should be laid in the hole of excavation 1 feet below ground level and having GI Reducer 50mm x 20mm with PVC Cap (For pouring water) fixed on the top level of the pipe. 300mm x 300mm x 300mm deep haudi of First class bricks finished with 1:4 cement plaster and haudi covered with cast iron lid having size 300mm x 300mm (Heavy) around the hole of excavation:-
38Earthing with 8 SWG (4mm dia.) copper wire thimbled with 30cm x 60cm x 2mm thick copper plate burried 4.50 metre (14.76 feet) below ground level (up to 8metre in Length) with G.I. pipe 20mm dia. (A-class), 3metre long
39Charges of ACB Servicing including Maintenance, Closing tripping coil, contact relays etc. (2) VCB Servicing including Maintenance, Closing tripping coil, Vacumm interruptor checking, IR test, COOC operation test, High pot test etc. (3) Dry type Transformer Servicing including visual inspection of trasformer core, tightining of HVLV terminal, IR test, PI test, turn ratio test, temprature sensor test etc. (4) Bus Bar contact resistance test, Measurement and IR test etc. complete in all respect.
40Providing Advance Lightning Protection System:-
41Providing Advance Lightning Protection System:-Supply, installation, testing & commissioning of fully autonomous Early Streamer Emission Lightning Air Terminal (ESEAT) comprising of floating panels/body isolated from an earthed central finial/tip (elevated sharp tip) on top of the highest point to protect from direct lightning strikes with the following technical parameters. As per NF C 17-102 : 2011, (Annexe C), Clause C.3.4 ESE terminal is tested & certified for the below parameters. • ESE air terminal should be tested for an Impulse current (10/350 micro sec)=103 KA • Charge (Q) = 54.9 A.s • Specific Energy (W/R) = 2500 KJ/Ω and as per Clause C.3 all the tests should be carried out on a sample (preferably all tests in one lab) according to the flow chart in figure C.1 (Sequence of testing) pg 69 i. General tests, ii. Mechanical tests, iii. Environmental tests, iv. Electrical tests, v. Early Streamer Test (Δt in 10μs to 60 μs and standard deviation) • For the local certification, the ESE air terminal should be tested for switching impulse current of 40 KA (8/20 micro sec) or more. LPI is Tested & certified by CPRI (Central Power Research Institute), Govt of India for the Impulse current of 70 KA with 5 positive & 5 negative impulse • The International testing laboratory should be duly accredited by ILAC / IEC / ENAC / EZU / UL to ensure the genuine testing and the quality of the product. The serial number displayed on the ese lightning arrester is duly supported with the \\"certificate of country of origin\\" issued and duly sealed by the Australian Government \\"Chamber of Commerce & Industry\\". Complete in all respect and as per design and size approved by engineer incharge at site.
42GALVANIZED IRON PIPES AND G.I. EARTHING: Supply & erection of G.I. pipe (A-Class) as per IS:1239 (Part-I) 2004 including sockets, bends, inspection boxes, Steel hooks, GI saddle clamps and other petty materials etc., where necessary including painting as per PWD General Specifications:-
43Galvanized Iron Pipe 50mm dia. (A-class) Flushed
44COPPER EARTHING (Upto 14 metre in Length):-iii- Earthing with electrolytic Copper Tape rivetted (with 5Nos. copper rivets)/Steel Nut & bolts (with 4Nos. 32mm long, 8mm thick with washer and double nut) to 30cm x 120cm x 2mm thick copper plate (made cylindrical) burried 10.50 metre (34.44 feet) below ground level in the hole of excavation having bore dia. 125mm and surrounded by salt & charcoal dust mixture (20 kg.) including fixing the Copper Tape recessed in wall and in floor etc., up to 14metre in Length (including bore Length). G.I. pipe 20mm dia. (A-class), 9metre long should be laid in the hole of excavation 1 feet below ground level and having GI Reducer 50mm x 20mm with PVC Cap (For pouring water) fixed on the top level of the pipe. 300mm x 300mm x 300mm deep haudi of First class bricks finished with 1:4 cement plaster and haudi covered with cast iron lid having size 300mm x 300mm (Heavy) around the hole of excavation:-
45Earthing with 20mm x 3mm Copper Tape (upto 14Metre in Length)
46PVC INSULATED SINGLE CORE FR COPPER CONDUCTOR CABLE:Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:-
47Overall size 70sq.mm (Un-sheathed)
48DESKTOP , COMPUTER, PRINTERS, ETC OTHER ACCESSORIES
49Supply and Installation of Computer 14th Generation intel core 17 processor 23.8\\" FHD display 16 GB DDR 5 RAM 1 TB SSD Hard disk Multimedia Keyboard, wireless Mouse, Speaker, LAN card and Modem, pre loaded legal window operating System software (with media), UPS 0.7 KVA (with 30 minutes back up) Computer complete as per specifications & as desired by Engineer-in-Charge.
50Supply and Installation of A 43-inch smart TV typically features a 4K UHD LED display, 60Hz refresh rate, and HDR support. Common smart systems include Android TV, Google TV, or Tizen, with built-in Wi-Fi, Bluetooth, 2-3 HDMI ports, and 20W+ speakers complete as per specifications & as desired by Engineer-in-Charge
51Supply and Installation of Laser print, Scan, Copier 3 in 1 Print machine Laser technology, Up to 30 PPM COLOURED MACHINE, Print Resolution: 600x600, Connectivity: Ethernet, 2GB Memory, 10.Inch Smart Touch Panel Zoom range 400%, HDD: 320 GB, Copy Speed: 25 cpm complete as per specifications & as desired by Engineer-in-Charge.
52Supply and Installation of Table Fan Commonly 400mm (16 inch) for standard, 200mm-300mm, High-speed My fans generally operate between 1300-2400 RPM, 40W to 115W Power Consumption., Usually 3 to 5 aerodynamic polypropylene blades, Plastic, ABS, or metal bodies, Oscillation (up to 180\\"), tilt adjustment, and 100% coppe complete as per specifications & as desired by Engineer-in-Charge.
53Supply and Installation of 14th gen Intel or AMD Ryzen 9 processors, 16GB RAM, and 1TB SSD, microsoft windows, MS Office, Antivirus etc Laptop complete as per specifications & as desired by Engineer-in-Charge.
54Supply and Installation of fans usually feature 35-41 L tanks, 3 speed settings, and 260-350W motors, capable of cooling up to 800-1400 sq. ft. through centrifugal misting Mist fan complete as per specifications & as desired by Engineer-in-Charge.
55Supply and insallation of PVC Extension box of suitable size with 3 Nos. sockets and 1 switch of 6 Amp each including PVC insultated PVC Sheathered round flexible wire with copper conductor (FR Cable) ISI Marked up to minimum 5mtr in length with 3 pin 6Amp shoe, complete in all respects as approved and desired by the Engineer-in-Charge
56Supply and insallation of PVC Extension box with 1. Nos switch and sockets of 16/20Amp each with extension wire with copper conductor (FR Cable) ISI Marked of min. 5mtr in length with 3 pin 16/20Amp shoe, complete in all respects as approved and desired by the Engineer-in-Charge.
57Add Cultural Cess 1% Please Enable Macros to View BoQ information

Other Detail

Information Source https://eproc.punjab.gov.in
Download FileName File Description File Size
Download BOQ_345907.xls Tender Documents 0 KB
Download ff79aab2-763f-4d7a-a69e-54e322e22647.html Tender Documents 0 KB
Download SBD.pdf Tender Documents 0 KB
Download Tendernotice_1.pdf Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.