Name of Work:- Urgent Electrical Installation Work at Ground Floor and 5th floor of SC/ST/OBC/Minorities handicapped Financial & Development Corporation, Ambedkar Bhawan, institutional Area Sector- 16, Rohini, Delhi | Sl. No. | Item Description | |
| 1 | SH-I EI work Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. a) Group C | | 2 | Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required. a) Group C | | 3 | Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed steel conduit, and earthing the point with 1.5 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. | | 4 | Rewiring for twin control light point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required. | | 5 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit/channel as required. a) 3 x 1.5 sq. mm | | 6 | b) 6 x 1.5 sq. mm | | 7 | c) 3 x 4 sq. mm | | 8 | d) 6 x 4 sq. mm | | 9 | Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. a)20 mm | | 10 | b)25 mm | | 11 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. a) 5/6 A switch | | 12 | b) 3 pin 5/6 A socket outlet | | 13 | c) 15/16 A switch | | 14 | d) 6 pin 15/16 A socket outlet | | 15 | e) Blanking Plate | | 16 | f) Bell push (SR Rohini, SR pitampura, SR Joint Pitampura) | | 17 | Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required. | | 18 | Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing andn fixing 25 A modular socket outlet and 25 A modular SP MCB,“C” curve including connections, painting etc. as required. | | 19 | Supplying and fixing 16 Amp, 3 pin plug top made of high quality unbreakable polycarbonate body, suitable for 230V AC single phase supply, complete as required. | | 20 | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. (For Wall Fan ) | | 21 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. | | 22 | Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required. a) 3 Module (100mmX75mm) (For Power Point and Stair Case) | | 23 | b)6 Module (200mmX75mm) | | 24 | c) 8 Module (125mmX125mm) | | 25 | d) 12 Module (200mmX150mm) | | 26 | SH :-II Fans, Light Fittings Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required. a) 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum) | | 27 | SITC of wall fan 400 mm sweep oscillating type having Metal blade complete with all accessories such as front jaali i/c connection etc. as reqd | | 28 | Supplying & fixing of 300/305 mm sweep 1300- 1400 RPM 230 Volt 1-ph 50 Hz AC heavy duty Exhaust fan in the existing opening including making good the damage, connection, testing and commissioning etc. as reqd. | | 29 | LED Panel light 2x2 ft. (System lumen efficacy ≥105 <120 lm/Watt) Supplying, installation, Testing & Commissioning of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -5 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K/ 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm) a) 36 watt | | 30 | LED Batten light (System lumen efficacy ≥105 <120 lm/Watt) Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85% ,Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -5 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate (T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm) a) 18- 22 watt | | 31 | Supplying, Installation, Testing & Commissioning of LED Mirror Light fitting of 10 Watt, 600 mm long, aesthetically designed with powder coated / chrome finish housing and opal diffuser, suitable for wall mounting over mirror, complete with inbuilt LED driver, operating on 230V AC supply, having low power consumption, glare free illumination and complete with all mounting accessories, connections, testing and commissioning etc. as required and as directed by Engineer-in-Charge. | | 32 | LED Down lighter (SMD Type) (System lumen efficacy ≥ 105 < 120lm/Watt) Supplying, installation, Testing & Commissioning of LED Recessed / surface Down lighter (Round/ square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80 , UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5%), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends , CCT 3000°K / 4000°K / 5700°K / 6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be confirming to relevant BIS standards and trade mark certificate (T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 and <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C) Powder coated die cast /Extruded aluminium Body including trim. a) 12 Watt | | 33 | Supplying, Installation, Testing & Commissioning of Decorative LED Post Top Lantern fitting suitable for outdoor lighting application, pressure die-cast aluminium housing with UV stabilized polycarbonate diffuser, having IP-65 protection, impact and corrosion resistant construction, glare-free optical system with better illumination uniformity, complete with high efficiency LED driver, power factor not less than 0.95, THD less than 10%, suitable for operation on 140-270V AC supply, mounted on existing/new pole with all required accessories, nuts, bolts, clamps, internal wiring etc. complete as required. a) 35 Watt | | 34 | SH :-III MCB, DB, Cabling and Panel Work Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) (For 5th Floor AC ) a) 4 way (4 + 12), Double door (2 nos-5th Floor AC DB, 1 Nos- 5th Floor Light DB, 1 no-3rd floor Light DBB) | | 35 | b) 8 way (4 + 24), Double door (For GF Light DB) | | 36 | Supplying and fixing Cable End Box (Loose Wire Box) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 Volts, on surface/ recess, complete with testing and commissioning etc.as required. a) For 4 way, Double door TPN MCBDB (2nos- 5th Floor AC DB and 1no-GF Light DB) | | 37 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. a) Single pole | | 38 | Providing and fixing following rating and breaking capacity and pole MCCB/TPN/SPN MCB with thermomagnetic release and terminal spreaders & associated switchgears in the above cubical panel board/TPDB including drilling holes in cubicle panel, fitting strips for MCB ,making connections, etc. as required. a) 100 A, 16 KA,TPMCCB ( 2nos- 5th Floor AC Db, 1nos-3rd Floor Ex Power DB, 1no-5th Floor Ex Power DB) | | 39 | b) 100 A, 10 KA , TPN MCB (C-Curve) (in LT Panel for AC DB) | | 40 | c) 63 Amp TPN MCB \\"C-Curve\\" 10 kA breaking capacity(For GF, 3rd Floor, 5th Floor Light DB) | | 41 | d) 63 A, 10 KA. DP MCB (for 2 Nos-GF Single Phase DB, 2 nos- In LT Panel) | | 42 | e) 400 A,50KA,FPMCCB (LT Panel) | | 43 | Providing and fixing sheet steel enclosure suitable for 400 Amp FP/TPN MCCB, fabricated out of CRCA MS sheet, dust and vermin proof, wall mounted type, having hinged door with locking arrangement, powder coated finish after proper surface treatment, , earthing terminals and complete with all hardware, nuts, bolts, connections, testing and commissioning etc. as required and as directed by Engineer-in-Charge. | | 44 | Supplying, Laying and fixing of one number PVC insulated and PVC sheathed / XLPE Aluminium conductor armoured power cable of 1.1 kV grade of following size on wall surface as required. (a) 3.5 X 70 sq. mm Alu. Cable.(For 5th Floor AC DB) | | 45 | (b) 3.5 X 50 sq. mm Alu. Cable.(For 3rd and 5th Floor Power DB) | | 46 | (c) 4 X 25 sq. mm Alu. Cable. (For GF, 3rd Floor and 5th Floor Light DB) | | 47 | (d) 3 X 16 sq. mm Alu. Cable. ( 60m for GF Single phase DB) | | 48 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required a) 3 X 16 sq. mm (25mm) ( 4 Nos for GF Single phase DB) | | 49 | b) 4 X 25 sq. mm (28mm) | | 50 | c) 3½ X 50 sq. mm (35mm) | | 51 | d) 3½ X 70 sq. mm (38mm) | | 52 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. | | 53 | SITC of 3 HP Monobloc booster pumpset having a discharge range of (250-110) LPM ± 10 % tolerance for head range of (24-36) Metre ± 10% tolerance suitable for operation on 3 phase, 340 50Hz AC supply i/c flange cable joint, gasket, nut & bolts etc as required. (For SR nangloi) | | 54 | SH :- IV Fire safety Supplying & fixing of following accessories of fire fighting safety system i/c testing & commissioning etc complete as required. a) Fire Bucket 24 gauge 9 ltr. Capacity (4- LT Panel, 4- HT Panel, 4- Meter Room) | | 55 | Fire bucket stand without bucket for fixing 4 bucket (Angle Type) (1- HT Panel and 1- LT Panel, 1- Meter Room) | | 56 | Supplying, Installation, Testing & Commissioning of Energy saving & environment friendly Laser Etched pendent type LED exit signage board bi-lingual super bright red/green LED's with Sign like hydrant, lift etc. Made of MS housing Powder Coated having acrylic sheet etched with super bright LED, power consumption less than < 2 watt, battery 7.4 volt lithium Ion 2200 mah with back up of 8 hoursrecharge period of 12 hours operating voltage of 190 to 230V etc. complete required. a) Double Side (Size of one Signage 14*6.4 inch, Total-9 Nos (3 Nos- Exit Sign, 3 Nos- Lift Lobby, 3 Nos- Water Cooler) | | 57 | Refilling of 6 Kg capacity ABC type fire extinguisher cylinder including opening of cylinder, removal of old extinguishing media, checking of internal condition, refilling with fresh MAP based ABC dry chemical powder of required capacity, replacement of defective ‘O’ rings, washers, hose pipe, nozzle and other minor accessories if required, repressurizing with dry nitrogen gas, leakage testing, safety checking, repainting, fixing of service tag/sticker and complete testing as per IS specifications complete in all respect as required and as directed by Engineer-in-Charge. (For SR nangloi and SDM nangloi). | | 58 | Supply and fixing of following ABC type fire extinguisher (ISI marked MAP 90%) complete delivery hose horn, squeeze grip release valve, locking arrangement on wall with the help of necessary clamps and duly painted in red colour etc. as reqd. a) 6 kg capacity ABC type fire extinguisher (ISI) | | 59 | Supply and fixing of 4.5 kg. capacity CO2 type fire extinguisher (ISI) marked complete delivery hose horn, squeeze grip release valve, locking arrangement on wall with the help of necessary clamps and duly painted in red colour etc. as reqd | | 60 | Supplying, Installation, Testing & Commissioning of EMERGENCY LIGHT providing through 16Watt Twin UL Listed High Intensity LED fitted Lamps with Adjustable Swivel Type Beam Lights fitted upon Powder Coated CRCA/MS Sheet Sleek Electronic Cabinet with Customized Signage fitted with 12V, 7AH SMF Battery giving Battery Backup of Upto 5 Hours provided with feature of Trickle Charging facilitating Overcharging and Low Battery Protection. Dual Tone LEDs with CRI Index greater than 90 provide maximum Smoke Penetration from each Lamp. Electrical Supply is suitable for 230V 50Hz AC fitted with Fuse safety. (1-HT Panel Room, 1-LT Panel Room, 1- Meter Room) | | 61 | Dismantling of existing Split Type Air Conditioner (STAC)of 1.5 TR / 2.0 TR capacity complete with indoor unit, outdoor unit, mounting arrangement, interconnecting copper piping, drain pipe, control cable, power cable and all associated accessories, carefully disconnecting electrical and refrigerant connections, recovering/shifting of material, dismantling from existing position and stacking safely at designated location within premises complete as required and as directed by Engineer-in-Charge. | | 62 | Reinstallation of existing Split Type Air Conditioner (STAC) unit of 1.5/ 2TR capacity including refixing of indoor and outdoor units at desired location, refixing of existing mounting brackets, reconnecting of refrigerant copper piping, drain pipe, control cable and power cable,with minor consumables, nuts, bolts, insulation tape and all accessories required for proper operation as directed by Engineer-in-Charge. (The item excludes refrigerant gas charging/refilling.) | | 63 | Supplying, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of 19 mm thick insulation as given below for Suction and Liquid lines, all accessories as per specifications etc. as required : a) 6.4 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm | | 64 | b) 12.7 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm | | 65 | c) 9.5 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm | | 66 | d) 15.86 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm | | 67 | Supplying & charging of Refrigerant gas (R- 22/32/refrigerant suitable as per requirement of AC unit) in the following type capacity AC units i/c leakage testing removing the leakage, pressure testing, flushing the complete system, vacuumizing and gas charging complete as required. | | 68 | Providing, laying, fixing, and commissioning of PVC (Polyvinyl Chloride) drain pipe for Air Conditioning units, including all necessary fittings such as elbows, tees, reducers, clamps, supports, adhesives, and accessories as required. | | 69 | SH :- V LAN Work Supplying, drawing, Installation, Testing and commissioning of CAT6 UTP LSZH 23AWG Twisted Pair Cable in existing conduit/ on surface, Category 6 Unshielded Twisted Pair, 4 pair should be complied as per UL/ETL verification program for compliance with ANSI/TIA-568.2-D standard. Outer diameter should be in the range of 6.1mm nominal with Operating Temperature Range : -5° to +60°C, Bending Radius : < 4 X Cable Diameter at –5°C ± 1°C and Pulling Force : 11.5Kg etc. complete as required. a) 1 Run of cable | | 70 | Supplying, Installation, Testing and commissioning of CAT6 Copper Information Outlet (IO) with face plate of color as per site requirement, should have ETL/UL verification program certificate for compliance with ANSI/TIA-568.2-D. All copper Cable and Components should be from same OEM to maintain compatibility and interoperability etc. complete as required. | | 71 | Supplying, Installation, Testing and commissioning of RJ45 Connector for CAT 6/6A Cables. RJ45 modular plug supports 4 twisted pairs, 8 positions, 8 connectors. Housing: PC, UL94V-2, transparent color, Use for 24- 26 AWG stranded wires etc. complete as required. | | 72 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. (For LAN and Work and AC Drain Arrangement) a) 25 mm Please Enable Macros to View BoQ information |
|