Indian Tenders

Tender Notice

TDR 55924200
Tendering Authority Public Works Department
Tender No ELSDM-09/2026-27
Tender ID 2026_PWD_855181_1
Tender Brief Tender For Deposit-Scheme For Basic Amenities To Public 2025-26 - Improvements Of Basic Amenities For Public At Changramkulam Police Station- Providing Flooring And Ceiling Works To The Existing Building In First Floor At Changaramkulam Police Statio
City Changaramkulam
State Kerala
Document Fees INR 565 /-
EMD INR 6356.0 /-
Tender Value INR 2.54 Lakhs /-
Tender Type Tender
Bidding Type Open Tender
Competition Type Indian

Tender Details

Tender for Deposit-Scheme For Basic Amenities To Public 2025-26 - Improvements Of Basic Amenities For Public At Changramkulam Police Station- Providing Flooring And Ceiling Works To The Existing Building In First Floor At Changaramkulam Police Station, Malappuram District.-Electrification-General Electrical Work

Key Dates

Publish Date 11-06-2026
Last Date of Bid Submission 18-06-2026
Tender Opening Date 22-06-2026

Contact Information

Company Name Public Works Department
Contact Person ASSISTANT EXECUTIVE ENGINEER
Address PWD ELECTRICAL SUBDIVISION MALAPPURAM

BOQ Items

Name of Work:- DEPOSIT-Scheme for Basic Amenities to Public 2025-26 - Improvements of Basic Amenities for Public at Changramkulam Police Station- Providing Flooring and Ceiling works to the existing building in First floor at Changaramkulam Police Station, Malappuram district.-Electrification-General Electrical Work
Sl. No. Item Description
1Wiring
21.10.3:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVCinsulated copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLSPVC insulated copper conductor single core cable etc as required.Group C
31.55.3:Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C
41.31:Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).
51.25:Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
690.3.21.3:Supply & installation of light fittings on 'C/U' shaped flat iron bracket Supply, conveyance, installation, testing and commissioning the light fittings of following types made from 0.5mm CRCA sheet complete with all accessories and lamps etc. directly on wall using 2 nos. 'C/U' brackets made from 20 x 3 mm MS flat, painting the flat iron bracket and giving connections with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS or extending the original wiring and giving connection etc. as required.1200 mm 1X20W LED Lamp with box type fixture
7OD43355/2026-2027:Supply,Conveyance, installation, testing and commissioning of 1800 lumen round/square surface/recess fitting made of die cast aluminum, having efficacy not less than 110l/w, pf greater than 0.95, THD less than or equal to 10% directly on ceiling and giving connections with 16/0.20mm 3 core PVC insulated and sheathed round copper conductor flexible wire or extending the original wiring and giving connections as required.(Chip make Cree/Osram/lumilled/Nichea) or equivalent make
8OD43943/2026-2027:Supply, conveyance, installation, testing and commissioning of LED Bulk head light fittings9W or nearest wattage directly on wall including giving connections with required length of16/0.20mm 3 core round copper conductor flex wire conforming to relevant ISS making goodthe damages, colour washing etc as required.
990.4.8:Charges for cutting holes suitable for accommodating exhaust fans up to 305mm sweep including plastering colour washing etc. as required.
10OD43945/2026-2027:Supply, conveyance, installation , testing and commissioning of 225/250 mm sweep Light DutyExhaust fan in metal frame working on 230 V A/C in the existing opening, fixing necessaryanchor bolts / bolt and nuts etc., as required including giving connections with the supplied wirealong with the exhaust fan.
1190.4.2:Supply and installation of suitable size MS belt type fan clamp fabricated from flat iron 40 x 6 mm, 150mm long x 2 Nos with M.S. rod bent to shape, neatly painted with 2 coats of enamel paint over a coat of red oxide primer as per IS 732 as required.
1290.4.5.4:Supply, Installation, testing and commissioning of ceiling fan of following sizes including wiring the down rods of standard length (up to 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.1200mm sweep - ceiling fan complete with service value minimum 4.0(cub meter/minute/Watt), Air delivery minimum 210(cubic meter/minute), Copper winding suitable for 230V/240V single phase AC supply
131.47:Supplying and fixing extra down rod of 10 cm length G.I. pipe, 15 mm dia, heavy gauge including painting etc. as required. (Note: More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)
14OD43354/2026-2027:Supply, conveyance, installation, testing and commissioning of 400/450mm sweep wall mounting fans with metallic blades, blade covers, body using mounting brackets supplied along with the fan and giving connection as required.
151.27.1:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm)
161.27.2:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)
171.27.5:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.8 Module (125mmX125mm)
181.24.1:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch
191.24.4:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet
201.24.3:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch
211.24.5:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet
221.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
231.17.3:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm
241.17.6:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.6 x 1.5 sq. mm
251.17.12:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm
2690.12.7.3:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.2 core 10 sq mm with factory made clamp
2790.12.7.42:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 25 sq mm with factory made clamp
2890.12.5.42:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.4 core 25 sq mm
299.1.2:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 10 sq. mm (19mm)
309.1.34:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 25 sq. mm (28mm)
3190.12.10.2:Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation50/38 mm or nearest size
3290.16.1.2:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.65 mm copper conductor (12 SWG)
3390.16.5.2:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.2.65 mm (12 SWG)
3490.16.1.3:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG)
3590.16.5.3:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG)
365.4:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
37OD44096/2026-2027:Providing and fixing 25 mm X 3 mm G.I. strip earth lead from the test joint to the earth plate
38OD44097/2026-2027:Providing and fixing 2 X 25 mm X 3 mm G.I. strip test joint for earthing system
3990.11.1.14:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43)
402.3.3:Supplying and fixing following way, single pole and neutral, sheet steel, MCBdistribution board, 240 volts, on surface/ recess, complete with tinned copperbus bar, neutral bus bar, earth bar, din bar, interconnections, powder paintedincluding earthing etc. as required. (But without MCB/RCCB/Isolator)12 way, Double door
412.10.1:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Single pole
422.12.1:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
432.14.2:Supplying and fixing following rating, double pole, (single phase and neutral),240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
442.13.2:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps
452.15.3:Supplying and fixing following rating, four pole, (three phase and neutral), 415volts, residual current circuit breaker (RCCB), having a sensitivity current 30milli Amperes in the existing MCB DB complete with connections, testing andcommissioning etc. as required.63 amps
462.11:Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
47OD44022/2026-2027:Supply and installation of 63 A, 415 V, 50 Hz, AC 23 A duty, TPN SDF units in sheet steelenclosure complete with handle assembly, door interlock and pad locking arrangement of thefollowing ratings on existing angle iron frame work or directly to wall using necessary bolts &nuts, fixing the unit to wall, making good the damages, colour washing etc. including givingnecessary connections as required including 16/20/25A HRC Fuse link
48OD44021/2026-2027:Supply & installation of dust and vermin proof, 3 Phase Syntax Meter Board( GS-MB- 6545)and to fix KSEB meters, fuse units etc as required including fixing it on wall, making good thedamages colour washing etc. as required.
49OD44023/2026-2027:Supplying and fixing 40/50/63A HRC Fuse link in existing SFU
50OD44024/2026-2027:Supplying and fixing 63 A, 2 Way neutral links mounted on DMC/SMC base with connections,in existing meter board
51OD44261/2026-2027:Supply and fixing 63mm dia 6Kgff/cm2 PVC pipe including fixing the pipe with clamp/clips at60cm spacing. etc as required
52OD44248/2026-2027:Supply and providing suitable Iron Hook Grouted on wall for binding the service wire
53OD47142/2026-2027:KSEB charge for meter shifting to new meter panel etc including preparing, submitting application in online/offline and arranging inspection of KSEB if required (Actual amount will be reimbursed on production of receipts) Please Enable Macros to View BoQ information

Other Detail

Information Source https://etenders.kerala.gov.in
Download FileName File Description File Size
Download 2cf597d8-88dc-4837-8d7b-938c75bac8c4.html Tender Documents 0 KB
Download BOQ_1445307.xls Tender Documents 0 KB
Download Conditions.pdf Tender Documents 0 KB
Download List.pdf Tender Documents 0 KB
Download Tendernotice_1.pdf Tender Documents 0 KB
Download viewsbd.pdf Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.