| 1 | SUB-HEAD - I : INTERNAL WIRING |
| 2 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group - C |
| 3 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. |
| 4 | 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 5 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 6 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 7 | 2 X 6 sq. mm + 1 X 4 sq. mm earth wire |
| 8 | 2 x 10 sq.mm + 1 x 6 sq.mm. earth wire |
| 9 | 4 X 6 sq. mm + 2 X 6 sq. mm earth wire |
| 10 | 4 x 10 sq.mm + 2 x 6 sq.mm. earth wire |
| 11 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. |
| 12 | 3 X 1.5 sq. mm |
| 13 | Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. |
| 14 | 250 mm X 300 mm X 60 mm deep |
| 15 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 16 | 5/6 A switch |
| 17 | 15/16 A switch |
| 18 | 3 pin 5/6 A socket outlet |
| 19 | 6 pin 15/16 A socket outlet |
| 20 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required |
| 21 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required |
| 22 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. |
| 23 | 12 Module (200mmX150mm) |
| 24 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 amps modular switch, connection etc. as required. |
| 25 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. |
| 26 | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. |
| 27 | Supplying and fixing Call Bell/Buzzer Suitable for single phase,230V,complete. as required. |
| 28 | Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required. |
| 29 | Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required Upto 450 mm sweep |
| 30 | Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 2 Nos 3 Pin 5/6 A modular socket outlet and 2 Nos 3 Pin 5/6 A Switch connections,etc. as required. |
| 31 | Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \\"C\\" curve including connections, painting etc. as required. |
| 32 | Supplying and fixing PVC batten/ angle holder including connections etc. as required. |
| 33 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 34 | 6 way (4 + 18), Double door |
| 35 | Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) |
| 36 | 4 way (4 + 12), Double door |
| 37 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 38 | Single pole |
| 39 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. |
| 40 | Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. |
| 41 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm diaincluding accessories, and providing masonry enclosure withcover plate having locking arrangement and watering pipe etc.with charcoal/ coke and salt as required |
| 42 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. |
| 43 | Supplying and erection of three piece nonlinear resistor type lightning arrestor suitable for 3 wire, 11 KV overhead lines with rated voltage 9 KV (rms) with a nominal discharge current rating of 5 KA and complete with galvanised clamping arrangement, G.I. bolts, nuts, washers etc. as required. |
| 44 | Supplying and erection of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) pole top bracket/ cross arm for single 33 KV over head line conductor complete with 50 mm X 6mm flat iron clamps, bolts and nuts including drilling holes for insulator pins, bolts, nuts, washers etc and painting with primer and finish paint as required. |
| 45 | Supplying and fixing following rating, four pole, (threephase and neutral), 415 volts, residual current circuitbreaker (RCCB), having a sensitivity current 30 mA inthe existing MCB DB complete with connections,testing and commissioning etc. as required. |
| 46 | PWD SOR 2018 /MARKET RATE |
| 47 | Supplying and fixing of following rating 240/415 V, 10 Kg. 'c' curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connection, testing and commissing etc. required. |
| 48 | S&F of 63 Amp. 4 pole MCB(10 KA) C Curve |
| 49 | S&F of 80 to 100 Amp 4 pole MCCB (16 KA) Thermal Magnetic release |
| 50 | Supply & laying of aluminium conducter, PVC insulated amoured, served, sheeted cable 1100 volts grade at a depth of 750mm below ground level over a cushion of 75mm thick sand alround and protected with burnt bricks on sides and top on surface, the cable run shall be fixed on M.S. clamp etc. of suitable size as per direction of Engineer-in-charge. complete in all respect the armouring of the cable shall be properly connected with the earth conductor by clamp etc. |
| 51 | 70.0 sq Mm*3.50 core. |
| 52 | 120.0 sq Mm*3.50 core. |
| 53 | Supply & Fixing of 20 Watt LED Surface Mounting weather proof Luminaire with PC Housing and opal finish cover confirming to IP 65 Complete in all respect. |
| 54 | Supply and fixing of factory wired integral LED flood light luminaires with die cast aluminium housing built with dirver set suitable for 100 to 120 Watt. Confirming to IP 65 protection complete in all respect. |
| 55 | S&F of 400 Amp. four pole change over switch on 50mm x 50mm x 6mm angle iron frame, including the cost of labour, T&P, painting and other material required for proper completion of the work as per direction and satisfaction of Engineer in charge. |
| 56 | Supply and fixing of fire extinguisher, ABC Type 6.00 Kg. capacity (ISI marke IS: 15683 & TAC approved) complete with initial charge and wall bracket, along with supply of all material and labour for proper completion of work. |
| 57 | S/F of CO2 extinguisher. ABC type 6.50 kg capasity (ISI Marked IS : 2878 & TAC aproved) complete with initial charge and wall bracket, along with supply of all mateials and labour for proper completion of work . |
| 58 | Supply and fixing of bucket, round bottom made of G.I. sheet 9-11 liters capacity duly painted as per fire brigade design supported on hanging bracket chined and locked, initially fitted with fine river sand, water as per directions of engineer in charge. |
| 59 | S&L of 1800 mm x 900 mm x 12 mm thick chequred rubber matting of tested quality |
| 60 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group - C |
| 61 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. |
| 62 | 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 63 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 64 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 65 | 2 X 6 sq. mm + 1 X 4 sq. mm earth wire |
| 66 | 2 x 10 sq.mm + 1 x 6 sq.mm. earth wire |
| 67 | 4 x 10 sq.mm + 2 x 6 sq.mm. earth wire |
| 68 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. |
| 69 | 3 X 1.5 sq. mm |
| 70 | Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. |
| 71 | 250 mm X 300 mm X 60 mm deep |
| 72 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 73 | 5/6 A switch |
| 74 | 15/16 A switch |
| 75 | 3 pin 5/6 A socket outlet |
| 76 | 6 pin 15/16 A socket outlet |
| 77 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required |
| 78 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required |
| 79 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. |
| 80 | 12 Module (200mmX150mm) |
| 81 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 amps modular switch, connection etc. as required. |
| 82 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. |
| 83 | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. |
| 84 | Supplying and fixing Call Bell/Buzzer Suitable for single phase,230V,complete. as required. |
| 85 | Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required. |
| 86 | Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required Upto 450 mm sweep |
| 87 | Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 2 Nos 3 Pin 5/6 A modular socket outlet and 2 Nos 3 Pin 5/6 A Switch connections,etc. as required. |
| 88 | Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \\"C\\" curve including connections, painting etc. as required. |
| 89 | Supplying and fixing PVC batten/ angle holder including connections etc. as required. |
| 90 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 91 | 6 way (4 + 18), Double door |
| 92 | Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) |
| 93 | 4 way (4 + 12), Double door |
| 94 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 95 | Single pole |
| 96 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. |
| 97 | Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. |
| 98 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm diaincluding accessories, and providing masonry enclosure withcover plate having locking arrangement and watering pipe etc.with charcoal/ coke and salt as required |
| 99 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. |
| 100 | Providing, laying and fixing following dia G.I. pipe (mediumclass) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required |
| 101 | 150 MM dia |
| 102 | Supplying and laying of following size DWC HDPE pipe ISI marke along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required. |
| 103 | 63 mm dia (OD-63 mm & ID-51 mm nominal) |
| 104 | 160 mm dia (OD-160 mm & ID-135 mm nominal) |
| 105 | Supplying and fixing of following rating 240/415 V, 10 Kg. 'c' curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connection, testing and commissing etc. required. |
| 106 | S&F of 63 Amp. 4 pole MCB(10 KA) C Curve |
| 107 | S&F of 80 to 100 Amp 4 pole MCCB (16 KA) Thermal Magnetic release |
| 108 | Supply & laying of aluminium conducter, PVC insulated amoured, served, sheeted cable 1100 volts grade at a depth of 750mm below ground level over a cushion of 75mm thick sand alround and protected with burnt bricks on sides and top on surface, the cable run shall be fixed on M.S. clamp etc. of suitable size as per direction of Engineer-in-charge. complete in all respect the armouring of the cable shall be properly connected with the earth conductor by clamp etc. |
| 109 | 70.0 sq Mm*3.50 core. |
| 110 | 120.0 sq Mm*3.50 core. |
| 111 | Supply and erection of factory fabricated and wired metal clad dust and vermin proof floor mounting panel TPN switch board complete with the following HRC type heavy duty TPN fuse switches with fuses and instrument chamber etc. complete in all respects. The instrument chamber shall be separate and shall comprise of flush type ammeter, voltmerer, selector switches for ammeter and voltmeter, instrument fuses, current transormer etc. The board shall have suitable capacity electroytic alumininum busbars as per IS8623 istulate with heat shrink sleeving and mountend on non hygroscopic supports such as CMC/DMC support with deteachable side covers and shall be suitable for extension on the sides. The switches shall be complete with suitable cable end boxes, reverse entery boxes in case of pedestaal type, cable sockets, compression glands and indicating lamp on incoming etc. The job includes the grounting of the board as per direction of Engineer-in-Charge. All coutgoing switches of 100 Amp. and above will be provided with ampere metre current transformers and selector switches and instrument fuses etc. The switches board shall be fabricated with CRCA sheet with a minimum thickness of 1.6 mm/2 mm. Cubicle type switch board shall be of cat A B & B-II and pedestal type for Cat-B and C only. |
| 112 | incoming MCCB 200 Amp- 01 no |
| 113 | Outgoing MCCB 100 Amp-01 no |
| 114 | outingoing MCCB 63 AMP-02 nos |
| 115 | Supply & Fixing of 20 Watt LED Surface Mounting weather proof Luminaire with PC Housing and opal finish cover confirming to IP 65 Complete in all respect. |
| 116 | Supply and fixing of LED Street Light fitting with mandatory driver set having die cast aluminium body and lenxes suitable for 75 Watt to90 Watt, confirming to IP 65 /66 Protection having Company LOGO Engraved complete in all Respects including labour . Mid power LED with lences . 100 Im / Watt. PF > 0.95 , THD < 10% at full load CRI > 70 , Potted drived set ( not circulatory ) , with 3 year warranty. |
| 117 | Supply and fixing of 200 Amp four pole change over switch on 50 mm x 50 mm x 6 mm angle iron frame, including the cost of labour, T&P, painting and other material required for proper completion of the work as per direction and satisfaction of engineer in charge. |
| 118 | Supply and fixing of fire extinguisher, ABC Type 6.00 Kg. capacity (ISI marke IS: 15683 & TAC approved) complete with initial charge and wall bracket, along with supply of all material and labour for proper completion of work. |
| 119 | S/F of CO2 extinguisher. ABC type 6.50 kg capasity (ISI Marked IS : 2878 & TAC aproved) complete with initial charge and wall bracket, along with supply of all mateials and labour for proper completion of work . |
| 120 | Supply and fixing of bucket, round bottom made of G.I. sheet 9-11 liters capacity duly painted as per fire brigade design supported on hanging bracket chined and locked, initially fitted with fine river sand, water as per directions of engineer in charge. |
| 121 | S&L of 1800 mm x 900 mm x 12 mm thick chequred rubber matting of tested quality |
| 122 | Providing and laying water proofing treatment on roofs of slab by applying cement slurry mixed with water proofing cement compound consisting of applying:a-After surface preparation, first layer of slurry of [email protected]/sqm mixed with water proofing cement [email protected]/sqm. b- Laying second layer of fiberglass cloth when the first layer is still green. Overlaps of joints of fiber cloths should not be less then 10cm.c- Third layer of 1.5mm thickness consisting of slurry of cement @ 1.289kg/sqm mixed with water proofing cement [email protected]/sqm and coarse sand @1.289kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken up to 30 cm. on parapet wall and tucked into groove in parapet all around. |
| 123 | Providing and applying fiber reinforced elastomeric liquid water proofing membrane with resilient acrylic polymers having sun reflectivity index (SRI )of 105 on top of concreate roof in three [email protected]/10 sqm. One coat of self priming of elastomeric waterproofing liquid (dilution with water in the ratio of 3:1) and two coats of undiluted elastomeric water proofing liquid(DFT of complete application /system not less then 500 micron).The operation shall be carried out after strapping and properly cleaning the surface to remove lose particals with wire brushes, complete in all respect as per the direction of engineer- in-charge |
| 124 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead |
| 125 | area 3 sq. metres and above |
| 126 | Fixing of Door, windows/ventilators chaukhats in position. |
| 127 | (a) Door |
| 128 | (b) Window |
| 129 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge |
| 130 | Providing and fixing ISI marked flush door shutters conforming to IS :2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws |
| 131 | Providing & fixing of Sliding door bolts (300x16mm) |
| 132 | Providing & fixing of tower bolts (250x10mm) |
| 133 | Providing & fixing of handle 125mm) |
| 134 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 135 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels,bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering,finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand derived from natural sources : 3 graded stone aggregate20 mm nominal size derived from natural sources). |
| 136 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete . Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 137 | above plinth |
| 138 | Excavation of Foundation-Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. DSR-2.8.1 |
| 139 | PCCProviding and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size) (DSR-4.1.8) |
| 140 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:4 (1 cement : 4 coarse sand)(DSR -6.1.1) |
| 141 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. 40 mm thick with 20 mm nominal size stone aggregate DSR 11.3.1 |
| 142 | 15 mm cement plaster on rough side of single or half brick wall of mix : 1:4 (1 cement: 4 coarse sand) (DSR-13.5.1) |
| 143 | 12 mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand) |
| 144 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.(Z-Section Window) |
| 145 | Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 4.0 mm thick glass panes |
| 146 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an evenshade Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture |
| 147 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : New work (two or more coats) over and including water thinnable priming coat with cement primer |
| 148 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. D.S.R. 13.80 |
| 149 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.110 mm diameter |
| 150 | Providing and fixing on wall face unplasticised- PVC moulded fittings/ accessories forunplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 110 mm Bend 87.5° |
| 151 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 110 mm |
| 152 | Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. Please Enable Macros to View BoQ information |