Indian Tenders

Tender Notice

TDR 55923607
Tendering Authority Madhyanchal Vidut Vitran Nigam Limited
Tender No 22/EDCB/2026-27
Tender ID 2026_MVVNL_1156704_1
Tender Brief Corrigendum : Tender For For Running Contract For Hon,Ble Sansad Nidhi/Vidhayak Nidhi And Other Deposit Works In Edsd-Sahaswan Under Edd-Ujhani (Semi Turnkey).
City Budaun
State Uttar Pradesh
Document Fees INR 3540 /-
EMD INR 35000.0 /-
Tender Value INR 35 Lakhs /-
Tender Type Tender
Bidding Type Open Tender
Competition Type Indian

Tender Details

Tender for For Running Contract For Hon,Ble Sansad Nidhi/Vidhayak Nidhi And Other Deposit Works In Edsd-Sahaswan Under Edd-Ujhani (Semi Turnkey).

Corrigendum Details

Sr No CorrigendumDate Corrigendum CorrigendumType NewSubmissionDate
1 16-06-2026 DATE EXTENSION1 Date 23-06-2026

Key Dates

Publish Date 16-06-2026
Last Date of Bid Submission 23-06-2026
Tender Opening Date 24-06-2026

Contact Information

Company Name Madhyanchal Vidut Vitran Nigam Limited
Contact Person SE, EDC, BDN
Address BUDAUN

BOQ Items

Name of Work:- For Running Contract for hon,ble Sansad Nidhi/Vidhayak Nidhi and other Deposit Works in EDSD-Sahaswan under EDD-Ujhani (Semi Turnkey).
Sl. No. Item Description
1The work of safe carriage of the following material from Navada Badaun store center to work site under the jurisdiction of LT/11 KV under EDD Ujhani. Approx. distance upto 70 Km. Including safe loading and unloading.
2PCC Pole 8.5 meter long.
3PCC Pole 09 meter long.
4PCC Pole 11 Mtr Long
5STP 11 Mtr Long
6STP 13 Mtr Long
7Line material i.e., cross arm/ pin insulator/stay/earthing rod/Ms Channel/MS Angle/Disc Fitting/Disc Insulators etc
811 KV XLPE Cable Size 3x70sqmm
911 KV XLPE Cable Size 3x120sqmm
1011 KV XLPE Cable Size 3x185sqmm
1111 KV XLPE Cable Size 3x300sqmm
12ACSR Weasel Conductor
13ACSR Rabbit Conductor
14ACSR Raccon Conductor
15ACSR Dog Conductor
163 Phase Arial Bunched Conductor
171 Phase Arial Bunched Conductor
18Distribution Box 1 Phase
19Distribution Box 3 Phase
2011 KV Cable Box Size 3x70sqmm
2111 KV Cable Box Size 3x120sqmm
2211 KV Cable Box Size 3x185sqmm
2311 KV fuse Set
24Straight Through
2511/0.4 KV 3 Phase 25 KVA T/F
2611/0.4 KV 3 Phase 63 KVA T/F
2711/0.4 KV 3 Phase 100 KVA T/F
2811/0.4 KV 3 Phase 250 KVA T/F
2911/0.4 KV 3 Phase 400 KVA T/F
3011 KV Pilfer proof Metering cubical and CT PT Unit
3111 KV VCB incoming/outgoing
32Erection of new PCC Single/Double pole in H.T/L.T lines including fitting of all accessories as per RESSPO Norms
33PCC Pole 8.5 Mtr Long Single Pole
34PCC Pole 8.5 Mtr Long Double Pole
35PCC Pole 09 Mtr Long Single Pole.
36PCC Pole 09 Mtr Long Double Pole.
37PCC Pole 11 Mtr Long Single Pole.
38PCC Pole 11 Mtr Long Double Pole.
39ST Pole 11 Mtr Long Single Pole.
40ST Pole 11 Mtr Long Double Pole.
41ST Pole 13 Mtr Long Single Pole.
42ST Pole 13 Mtr Long Double Pole.
43Grouting with 1:4:8 mixture in size(450x450x1500mm.) including cost of cement/Concreate & sand Required as per RESSPO Norms
44PCC Pole 8.5 Mtr Long Single Pole
45PCC Pole 8.5 Mtr Long Double Pole
46PCC Pole 09 Mtr Long Single Pole.
47PCC Pole 09 Mtr Long Double Pole.
48PCC Pole 11 Mtr Long Single Pole.
49PCC Pole 11 Mtr Long Double Pole.
50ST Pole 11 Mtr Long Single Pole.
51ST Pole 11 Mtr Long Double Pole.
52ST Pole 13 Mtr Long Single Pole.
53ST Pole 13 Mtr Long Double Pole.
54Dismantling of PCC/ST Pole due to line shifting/damagedcomplete in all respect
55ST Pole 9 Mtr Long Single Pole.
56ST Pole 9 Mtr Long Double Pole.
57ST Pole 11 Mtr Long Single Pole.
58ST Pole 11 Mtr Long Double Pole.
59ST Pole 11 Mtr Long Tri Pole.
60ST Pole 11 Mtr Long Four Pole.
61LT ABC (3x95+1x70+1x16) SQ. MM
62LT ABC (3x120+1x95+1x16) SQ. MM
63Dismantling of Old and damaged conductor complete in all respect
64Dismantling of Existing Distribution Transformer forincreasing capacity/Shifting complete in all respect
6511/0.4 KV 3 Phase 25 KVA T/F
6611/0.4 KV 3 Phase 63 KVA T/F
6711/0.4 KV 3 Phase 100 KVA T/F
6811/0.4 KV 3 Phase 250 KVA T/F
6911/0.4 KV 3 Phase 400 KVA T/F
70Laying, Stringing & Sagging of Following Conductorcomplete in all respect
71ACSR Weasel Conductor
72ACSR Rabbit Conductor
73ACSR Raccon Conductor
74ACSR Dog Conductor
753 Phase Arial Bunched Conductor
761 Phase Arial Bunched Conductor
77Erection and fixing of Overhead Line By XLPE Cable Complete in all respect.
7811 KV XLPE Cable Size 3x70 sqmm
7911 KV XLPE Cable Size 3x120 sqmm
8011 KV XLPE Cable Size 3x185 sqmm
81Mounting of CT PT unit on double pole complete in all respect.
82Installation of 11 KV Pilfer Proof Metering Cubicle in metering room complete in all respect
8311 KV VCB incoming/outgoing installation
84Under ground laying of Following cable in Single circuit on river sand to Double pole situated at both sides of road complete in all respect. Minimum depth should be 0.75 Mtr and cable should be covered by bricks from three sides.
8511 KV XLPE Cable Size 3x70 sqmm
8611 KV XLPE Cable Size 3x120 sqmm
8711 KV XLPE Cable Size 3x185 sqmm
8811 KV XLPE Cable Size 3x300 sqmm
89Under ground laying of Following cable in Single circuit by drill method to Double pole situated at both sides of NH/SH/Railway Crossing (with HDPE Pipe if required) complete in all respect.
9011 KV XLPE Cable Size 3x70 sqmm
9111 KV XLPE Cable Size 3x120 sqmm
9211 KV XLPE Cable Size 3x185 sqmm
9311 KV XLPE Cable Size 3x300 sqmm
94Hoisting of Following size 11 KV & 33 KV XLPE Cable on double pole with GI pipe of size 6 \\" dia 4 Mtr long including the jumpering complete with clamps , nut and bolts
9511 KV XLPE Cable Size 3x70 sqmm
9611 KV XLPE Cable Size 3x120 sqmm
9711 KV XLPE Cable Size 3x185 sqmm
9811 KV XLPE Cable Size 3x300 sqmm
99Supply & Laying of G.I. Pipe at various places i.e road crossing & Hoisting etc. complete in all respect (GI pipe would be Provided by contractor at his own cost)
100Supply & Laying of HDPE Pipe at various places i.e road crossing & Hoisting etc. complete in all respect (HDPE pipe would be Provided by contractor at his own cost).
101The work of Driving the earthing electrode and making connections with 6 S.W.G. GI wire as per RESSPO Norms
102Chemical earthing of T/F & Fencing including all materials (chemical, gi pipe, gi strip, nut bolt, etc)
103Earthing of distribution T/F for body & neutral upto water level with GI Pipe of 1.5\\" Dia. Including GI strip size 35x6 mm. (all material will be supplied by Contractor).
104Construction of 250/400 KVA T/F plinth 2x2x1.5 Mtr. for mounting T/F including foundation work (below ground 0.5 M), Brick work, RCC slab of 4” thickness and plastering in 1:6 ratio with 02 Nos channel pieces of 1.5 mtr long of size 100x50x6 mm compete in all respect as per UPPCL Norms.
105Cage fencing of 250/400 KVA Plinth mounted transformer in Town areas to avoid electrical human/cattle accidents by fabrication of cage (1 Inch Sq wire mesh) made of 10 No gauge in suitable size angle iron frame of size 7.5'(L)x5'(W)x8'(H) by strengthening of wire mesh 20x3 mm M.S. flat horizontally as well as vertically, Grouting the panel with 1:2:4 cement/coorse send/brick ballast. The Frame should be bolted on angles at the four corners so that frame may be un-bolted/bolted at the time of replacement of the transformer. Provision of 1 gate should be there for maintenance of the transformer. Painting (1 coat of red oxide + 2 coat of Bus green enamel paint). The wire mesh should be earthed with 50x6 mm MS earthing strip with existing earthing of Transformer Body. All manpower, material and T&P provided by the contractor to complete the fabrication, transportation and installation.
106The work of digging of pits, erection of Stay Clamp, Insulator etc.
107Grouting of stays, 1:4:8 cc ratio (600x600x300mm.) as per RESPO norms.
108Installation of 11 KV Pilfer Proof Metering Cubicle in metering room complete in all respect
109Mounting of Following Capacity Transformers as per norms complete in all respect
11025 KVA T/F
11163 KVA T/F
112100 KVA T/F
113250 KVA T/F
114400 KVA T/F
115Fixing of Distribution Box complete in all respect
116Guarding at road crossing complete in all respect
117Errection & Fixing of Cable box
11811 KV Cable Box Size 3x70sqmm
11911 KV Cable Box Size 3x120sqmm
12011 KV Cable Box Size 3x185sqmm
12111 KV Cable Box Size 3x300sqmm
122Straight Through 11 KV Cable Box Size 3x70sqmm,3X120sqmm,3x185sqmm)
123Cutting of Tree Branch Comming Near Line
124Supply & Fixing of Following Items to complete the work (If Not available in stores)
125LT Clamps
126Nut & Bolt off size
127F Clamp
128LT Fuse Set Protection unit for tf with SMC Box
129X-Arm Holding Clamp
130clamps for top, t-off & other channel etc.
131Stay Clamps
132Three Phase Distribution Box Clamp (LS)
133Dead End Clamp
134Eye Hook
135J Hook
136Tailless Unit for 250 & 400 kVA TF
137Barbed Wire
138Red Oxide Paint
139Aluminum Paint
140Number Plate
141Al. Lugs 70 Sqmm mm
142Al. Lugs 150 Sqmm mm
143Al. Lugs 240 Sqmm mm
144Al. Lugs 400 Sqmm mm
14511 KV DO Fuse Set
146Garding Angle
147Garding Angle Clamp with Nut & Bolt
148Suspension Clamp for XLPE Overhead
149Danger Board
150Stone Pad
151M.S. Top Channel
152M.S. T-off Channel
153MS angle T/F Base
154Dropper Channel
155Safe back carriage of Distribution Transformer from work site to Nawada Store approx. distance upto 70 Km including safe loading & unloading.
156A.B. Cable Scrap
157Iron Scrap
158STP Pole Scrap
159ACSR Weasel Conductor Scrap
16011/0.4 KV 3 Phase 25 KVA T/F
16111/0.4 KV 3 Phase 63 KVA T/F
16211/0.4 KV 3 Phase 100 KVA T/F
16311/0.4 KV 3 Phase 250 KVA T/F
16411/0.4 KV 3 Phase 400 KVA T/F
165Note:-All Item Rate filling with GST by the firm Please Enable Macros to View BoQ information

Other Detail

Information Source https://etender.up.nic.in
Download FileName File Description File Size
Download BOQ_2167456.xls Tender Documents 0 KB
Download f050137a-19c1-4604-a6d5-be621b092cd3.html Tender Documents 0 KB
Download Tendernotice_1 (21).pdf Tender Documents 0 KB
Download Tender_form22.pdf Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.