Indian Tenders

Tender Notice

TDR 55922952
Tendering Authority Military Engineer Services
Tender No 8658
Tender ID 2026_MES_754442_3
Tender Brief Corrigendum : Tender For special Repair / Replacement Of Old / Unsv Lt Feeder Pillar Boxes & Lt Control Panels At Certain E/M Installations At Afa Hyderabad.
City Hyderabad
State Telangana
Document Fees INR 500 /-
EMD INR 97100.0 /-
Tender Value INR 48.55 Lakhs /-
Tender Type Tender
Bidding Type Open Tender
Competition Type Indian

Tender Details

Tender for special Repair / Replacement Of Old / Unsv Lt Feeder Pillar Boxes & Lt Control Panels At Certain E/M Installations At Afa Hyderabad.

Corrigendum Details

Sr No CorrigendumDate Corrigendum CorrigendumType NewSubmissionDate
1 16-06-2026 CORRIGENDUM NO. 02 BOQ 26-06-2026

Key Dates

Publish Date 16-06-2026
Last Date of Bid Submission 26-06-2026

Contact Information

Company Name Military Engineer Services
Contact Person GE (AFA) Hyderabad
Address GE (AFA) Hyderabad, Dundigal, Hyderabad

BOQ Items

Name of Work:- SPL REPAIR / REPLACEMENT OF OLD / UNSV LT FEEDER PILLAR BOXES & LT CONTROL PANELS AT CERTAIN E/M INSTALLATIONS AT AFA HYDERABAD.
Sl. No. Item Description
1Supply, install, commissioning & testing of Motor Control Panel \\"out-door type\\" of size 900 mm (height) x 900 mm (breadth) x 500 mm (depth) (minimum dimensions) factory fabricated CPRI approved (type-tested) with suitable neoprene rubber gasket to make it completely dust & vermin proof & degree of protection not less than IP-55 & general construction confirming to IS-13947, double door, front & back openable. The panel shall be provided with ventilation facility in the form of louvers for better heat dissipation & tinned copper bus-bar wrapped with coloured PVC tape/sleeves of rating in conformity to the Incoming MCCB/MCB rating. The panel board shall be fabricated out of 3.15 mm thick (for outer portions) & 2.0 mm thick (for inner portions) CRCA sheet duly pre-treated & powder coated, supporting angle iron frame & MC channel base suitable for 3 Ph, 4 wire system 415/440 volts grade incl complete internal wiring with not less than 2.5 sqmm copper wire incl cable glands of suitable sizes incl suitable PCC (1:3:6) type C-2 foundation , necessary earthwork (if any) incl taking down old unsv one complete all as specified & as directed & to the entire satisfaction of the Engr-In-Charge with & incl the following accessories : [ For Watch Tower Borewells ]
2BUS-BAR & INTERNAL CONNECTIONS :The bus-bars shall be made up of 04 Nos high grade Aluminium 100 A rated, duly insulated with 1100 V grade standard colour coded PVC sleeves & rigidly mounted on suitable sized \\"F\\" class insulators of non-hygroscopic, non-combustible, all internal connections from main bus-bars to switch gears etc.PROVISION FOR CABLE ENTRY :The provision for cable entry/exit shall be provided in the bottom for both incoming & out-going cables with the help of glands matching the existing LT cable sizes.INCOMING :(a) MCCB 4P (Ics = 100% Icu) with thermal magnetic release, adjustable short circuit & adjustable overload setting,suitable for isolation, having breaking capacity 25 KA & of rating 20 to 32 A - 01 Nos. Make : Cat No : DZ0F0020-32CXC1AOOOO of Make L&T or techno-commercially equivalent of LEGRAND/SIEMENS.OUTGOINGS :(a) MCB, SPN, 10KA, 230V, \\"C\\" curve, 06-32 A, ISI marked - 03 Nos (2W + 1S). Make : LEGRAND/ABB/SIEMENS(b) Single Phase DOL Starter perfectly suitable for Submersible Pumping Set of capacity upto 2 HP, conforming to IS/IEC : 60947-4-1, IP-54, with & incl Extended wide band coil, FRLS Copper Internal Wiring, Starter Type - Air Break, Class-H Insulation with Contactor Rating - 12A, Overload Relay Range - 2.8A to 4.2A incl testing complete. Make : SIEMENS/L&T/HAVELLS/BCH - 02 Nos (1W + 1S)INSTRUMENTATION SYSTEM :(a) Digital type Multi-Function meter with built in selector Switch & 03 Nos CTs matching with the I/C breaker, Accuracy Class - 1.0, 3 phase, Size 96 x 96 mm. Make : Cat No WL411010OOOO of make L&T or techno-commercially equivalent of ELMEASURE/SECURE.(b) Indicator lamp with integral circuit (230/240V) & cluster LED (Red, Orange, Blue) - 01 Set.(c) Danger notice plate of size 20 x 15 cm of 1.6mm thick mild-steel sheet, vitreous enamelled white, with letters, figures and conventioinal skul and bones in signal-red colour and fixed with MS clamps, bolts and nuts of approved size, for LT conforming to IS-2551 - 02 Nos (Front & Back).
3Supply, install, commissioning & testing of Motor Control Panel \\"out-door type\\" of size 1200 mm (height) x 1000 mm (breadth) x 600 mm (depth) (minimum dimensions) factory fabricated CPRI approved (type-tested) with suitable neoprene rubber gasket to make it completely dust & vermin proof & degree of protection not less than IP-55 & general construction confirming to IS-13947, double door, front & back openable. The panel shall be provided with ventilation facility in the form of louvers for better heat dissipation & tinned copper bus-bar wrapped with coloured PVC tape/sleeves of rating in conformity to the Incoming MCCB/MCB rating. The panel board shall be fabricated out of 3.15 mm thick (for outer portions) & 2.0 mm thick (for inner portions) CRCA sheet duly pre-treated & powder coated, supporting angle iron frame & MC channel base suitable for 3 Ph, 4 wire system 415/440 volts grade incl complete internal wiring with not less than 2.5 sqmm copper wire incl cable glands of suitable sizes incl suitable PCC (1:3:6) type C-2 foundation , necessary earthwork (if any) incl taking down old unsv one complete all as specified & as directed & to the entire satisfaction of the Engr-In-Charge with & incl the following accessories : [ For Other Borewells ]
4BUS-BAR & INTERNAL CONNECTIONS :The bus-bars shall be made up of 04 Nos high grade Aluminium 100 A rated, duly insulated with 1100 V grade standard colour coded PVC sleeves & rigidly mounted on suitable sized \\"F\\" class insulators of non-hygroscopic, non-combustible, all internal connections from main bus-bars to switch gears etc.PROVISION FOR CABLE ENTRY :The provision for cable entry/exit shall be provided in the bottom for both incoming & out-going cables with the help of glands matching the existing LT cable sizes.INCOMING :(a) MCCB 4P (Ics = 100% Icu) with thermal magnetic release, adjustable short circuit & adjustable overload setting,suitable for isolation, having breaking capacity 25 KA & of rating 40 to 50 A - 02 Nos. Make : Cat No : DZ0F0050CXC1AOOOO of Make L&T or techno-commercially equivalent of LEGRAND/SIEMENS.(b) Compact Enclosed ATS (Automatic Transfer Switch) suitable for inside panel mounting & I-O-II operation, 4 Pole, 63 A, confirming to IEC 60947-6-1 - 01 No complete with following features/specifications : (i) Double-Break Contact System offering High Short-time Withstand.(ii) Ample Space for Cable Termination.(iii) Ease of Generator Control (ON-OFF, Cooling Cycle Self-Test).(iv) Cyclic Event Logger.(v) Priority Source Selection.(vi) Adjustable Time Delay (0.1 Sec to 3 Hrs).(vii) Suitable for 3-Phase as well as 1-Phase sources.(viii) Protections - UV/OV, Phase Sequence, Single Phasing, Frequency.(ix) Terminal Shrouds, Phase Barriers & Source Separator etc.Cat No : 1SYN151254R1001 of make ABB or techno-commercially equivalent of L&T/Siemens. Please Enable Macros to View BoQ information
5BUS-BAR & INTERNAL CONNECTIONS :The bus-bars shall be made up of 04 Nos high grade Aluminium 100 A rated, duly insulated with 1100 V grade standard colour coded PVC sleeves & rigidly mounted on suitable sized \\"F\\" class insulators of non-hygroscopic, non-combustible, all internal connections from main bus-bars to switch gears etc.PROVISION FOR CABLE ENTRY :The provision for cable entry/exit shall be provided in the bottom for both incoming & out-going cables with the help of glands matching the existing LT cable sizes.INCOMING :(a) MCCB 4P (Ics = 100% Icu) with thermal magnetic release, adjustable short circuit & adjustable overload setting,suitable for isolation, having breaking capacity 25 KA & of rating 40 to 50 A - 02 Nos. Make : Cat No : DZ0F0050CXC1AOOOO of Make L&T or techno-commercially equivalent of LEGRAND/SIEMENS.(b) Compact Enclosed ATS (Automatic Transfer Switch) suitable for inside panel mounting & I-O-II operation, 4 Pole, 63 A, confirming to IEC 60947-6-1 - 01 No complete with following features/specifications : (i) Double-Break Contact System offering High Short-time Withstand.(ii) Ample Space for Cable Termination.(iii) Ease of Generator Control (ON-OFF, Cooling Cycle Self-Test).(iv) Cyclic Event Logger.(v) Priority Source Selection.(vi) Adjustable Time Delay (0.1 Sec to 3 Hrs).(vii) Suitable for 3-Phase as well as 1-Phase sources.(viii) Protections - UV/OV, Phase Sequence, Single Phasing, Frequency.(ix) Terminal Shrouds, Phase Barriers & Source Separator etc.Cat No : 1SYN151254R1001 of make ABB or techno-commercially equivalent of L&T/Siemens. Please Enable Macros to View BoQ information

Other Detail

Information Source https://defproc.gov.in/nicgep/app
Download FileName File Description File Size
Download 5b3ff2c5-b798-4506-b502-4b91b49f77dd.html Tender Documents 0 KB
Download BOQ_863679.xls Tender Documents 0 KB
Download Tendernotice_1.pdf Tender Documents 0 KB
Download TNDPAGES8658.pdf Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.