Indian Tenders

Tender Notice

TDR 55922924
Tendering Authority Military Engineer Services
Tender No GE I R AND D/CHD-12/2026-27
Tender ID 2026_MES_771069_1
Tender Brief Tender For Repair And Replacement Of Unserviceable Flameproof Wiring,Fans, Lights And Other Connected Items And General Internal Electrical Maintenance At Technical Area Of Tbrl Range Ramgarh
City Ramgarh
State Haryana
Document Fees INR 500 /-
EMD INR 96000.0 /-
Tender Value INR 48 Lakhs /-
Tender Type Tender
Bidding Type Open Tender
Competition Type Indian

Tender Details

Tender for Repair And Replacement Of Unserviceable Flameproof Wiring,Fans, Lights And Other Connected Items And General Internal Electrical Maintenance At Technical Area Of Tbrl Range Ramgarh

Key Dates

Publish Date 10-06-2026
Last Date of Bid Submission 01-07-2026
Tender Opening Date 03-07-2026

Contact Information

Company Name Military Engineer Services
Contact Person GE I R AND D Chandigarh
Address Garrison Engineer I R and D, DIHAR Base Lab, Ground Floor, Near 3 (BRD) AF Stn, Industrial Area, Ph-II, Ramdarbar, Chandigarh

BOQ Items

Name of Work:- REPAIR AND REPLACEMENT OF UNSERVICEABLE FLAMEPROOF WIRING,FANS, LIGHTS AND OTHER CONNECTED ITEMS AND GENERAL INTERNAL ELECTRICAL MAINTENANCE AT TECHNICAL AREA OF TBRL RANGE RAMGARH
Sl. No. Item Description
1Dismantling and taking down carefully by sub main wiring/service connection of any type (normal/flameproof) complete all as specifed and directed. Note:Location, route, quantity size and type of new submain wiring may be different from old submain wiring as per site requirement and credit shall be measured and issued as per actual.
2Material and labour for sub main wiring using PVC insulated and unsheathed fire retardant low smoke and halogen (FRLS-H) copper conductor single core multi stranded unsheathed copper cable 2x2.5 sqmm (for Phase and neutral) and earth continuity conductor of size 1x2.5 sqmm multistranded copper conductor FRLS-H 1100V using approved colour code for phase and neutral as per IS code drawn through ERW steel/SS conduit pipe, 20 mm outer dia (Minimum dia). The external dia shall be increased as per actual site requirement in accordance with clause No 19.125 of SSR Part I (ISI marked) including fixing of conduit on surface / wall/ roof complete all as specified and directed. Note : (i) 3 runs of 2.5 sqmm copper cable & 1 run of 20 mm (Minimum dia) ERW steel/SS conduit pipe shall be measured as one unit. (ii) The rate of fixing the steel conduits on surface / wall / roof alongwith the fittings / fixtures like elbow, bends,union, steel sadles, screws, conduit etc. shall be deemed to be included in unit rate quoted and nothing extra shall be paid for this. (iii) Location, route, quantity size and type of new submain wiring shall be different from old submain wiring as per site requirement.Nothing extra shall be admissible on this account.
3Material and labour for sub main wiring using PVC insulated and unsheathed fire retardant low smoke and halogen (FRLS-H) copper conductor single core multi stranded unsheathed copper cable 2x10 sqmm (for Phase and neutral) and earth continuity conductor of size 1x10 sqmm multistranded copper conductor FRLS-H 1100V using approved colour code for phase and neutral as per IS code drawn through ERW steel/SS conduit pipe, 25 mm outer dia (Minimum dia). The external dia shall be increased as per actual site requirement in accordance with clause No 19.125 of SSR Part I (ISI marked) including fixing of conduit on surface / wall / roof complete all as specified and directed. Note : (i) 3 runs of 10.0 sqmm copper cable & 1 run of 25 mm (Minimum dia) ERW steel/SS conduit pipe shall be measured as one unit. (ii) The rate of fixing the steel conduits on surface/wall/roof alongwith the fittings / fixtures like elbow, bends,union, steel sadles, screws, conduit etc. shall be deemed to be included in unit rate quoted and nothing extra shall be paid for this. (iii) Location, route, quantity size and type of new submain wiring shall be different from old submain wiring as per site requirement.Nothing extra shall be admissible on this account.
4Material and labour for sub main wiring using PVC insulated and unsheathed fire retardant low smoke and halogen (FRLS-H) copper conductor single core multi stranded unsheathed copper cable 4x16 sqmm (for 3- Phase and neutral) and earth continuity conductor of size 1x16 sqmm multistranded copper conductor FRLS-H 1100V using approved colour code for phase and neutral as per IS code drawn through ERW steel/SS conduit pipe, 32 mm outer dia (Minimum dia). The external dia shall be increased as per actual site requirement in accordance with clause No 19.125 of SSR Part I (ISI marked) including fixing of conduit on surface / wall complete all as specified and directed. Note : (i) 5 runs of 16.0 sqmm copper cable & 1 run of 32 mm (Minimum dia) ERW steel/SS conduit pipe shall be measured as one unit. (ii) The rate of fixing the steel conduits on surface/wall/roof alongwith the fittings / fixtures like elbow, bends, union, steel sadles, screws, conduit etc. shall be deemed to be included in the unit rate quoted and nothing extra shall be paid for this. (iii)Location, route, quantity size and type of new submain wiring may be different from old submain wiring as per site requirement.Nothing extra shall be admissible on this account.
5Supply and fixing flameproof (FLP/WP) rotary on/off switch 16A single pole with termination box in LM6 incl dismantling and taking down old u/s switch normal / Flameproof any type any capacity as per actual available at site complete all as specified and directed.
6Supply and fixing flameproof (FLP/WP) rotary on/off switch 16A single pole with termination box in LM6 incl dismantling and taking down old u/s switch normal / Flameproof any type any capacity as per actual available at site complete all as specified and directed.
7Supply and fixing flameproof (FLP/WP) plug in Switch Socket and plug combined 16 Amp, 3-pin, (2P+E) with termination box in LM6 incl dismantling and taking down old u/s switch socket normal / flameproof any type any capacity as per actual available at site complete all as specified and directed.
8Supply and fixing flameproof (FLP/WP) plug in Switch Socket and plug combined 25 Amp, 3-pin, (2P+E) with termination box in LM6 incl dismantling and taking down old u/s switch socket normal / Flameproof any type any capacity as per actual available at site complete all as specified and directed.
9Supply and fixing flameproof (FLP/WP) plug in switch socket and plug combined 32 Amp, 5-pin, (4P+E) with termination box in LM6 incl dismantling and taking down old u/s switch socket normal / Flameproof any type any capacity as per actual available at site complete all as specified and directed.
10Supply and fixing flameproof (FLP/WP) junction box 4 way junction box 120 mm dia incl dismantling and taking down old u/s junction box normal / Flameproof any type any capacity as per actual available at site complete all as specified and directed. Note: (i) Most of FLP items are installed in blds of height upto 8 mtrs and Rate of arrangement (ladder/Scaffolding) for reaching at a height for dismantling and taking down old u/s and fixing of new shall be deemed to be included in unit rate quoted.
11Supply and fixing flameproof (FLP/WP) well glass LED light fixture of 70 watt incl dismantling and taking down old u/s light fitting normal / Flameproof any type any capacity as per actual available at site complete all as specified and directed. Note: (i) FLP fixtures shall be installed in bldings of height upto 8 m and rate of arrangement (ladder/Scaffolding) for reaching at a height for dismantling and taking down old u/s and fixing of new shall be deemed to be included in unit rate quoted.
12Supply and fixing flameproof (FLP/WP) well glass LED light fixture of 90 watt incl dismantling and taking down old u/s light fitting normal / Flameproof any type any capacity as per actual available at site complete all as specified and directed. Note: (i) FLP fixture shall be installed in buildings of height upto 8 m and rate of arrangement (ladder/Scaffolding) for reaching at a height for dismantling and taking down old u/s and fixing of new shall deemed to be included in the unit rate quoted.
13Supply and fixing flameproof (FLP/WP) well glass LED light fixture of 100 watt incl dismantling and taking down old u/s light fitting normal / Flameproof any type any capacity as per actual available at site complete all as specified and directed. Note: (i) FLP fixture shall be installed in buildings of height upto 8 m and rate of arrangement (ladder/Scaffolding) for reaching at a height for dismantling and taking down old u/s and fixing of new shall be deemed to be included in unit rate quoted.
14Supply and fixing flameproof (FLP/WP) LED tube light fixture of 2x20 watt 4 feet incl dismantling and taking down old u/s light fitting normal / Flameproof any type any capacity as per actual available at site complete all as specified and directed. Note: (i) FLP fixture shall be installed in buildings of height upto 8 m and Rate of arrangement (ladder/Scaffolding) for reaching at a height for dismantling and taking down old u/s and fixing of new shall be deemed to be included in unit rate quoted
15Supply and fixing flameproof (FLP/WP) single pole and neutral lighteing distribution panel 12 Way incl incoming MCB 2 pole 'C' curve 63 Amps -01 No. and outgoing MCB SP 6 Amp-12 Nos with complete internal bus bar and wiring up terminals complete incl dismantling and taking down old u/s DB normal / Flameproof any type any capacity as per actual available at site complete all as specified and directed. Note: MCBs shall be deemed to be included in unit rate quoted without any extra charge.
16Supply and fixing flameproof (FLP/WP) three pole and neutral lighteing distribution panel 04 Way incl incoming MCB 4 pole 'C' curve 63 Amps -01 No. and outgoing MCB SP 'C' 6 Amp-12 Nos with complete internal bus bar and wiring up terminals complete incl dismantling and taking down old u/s DB normal / Flameproof any type any capacity as per actual available at site complete all as specified and directed. Note: MCBs shall be deemed to be included in unit rate quoted without any extra charge.
17Supply and fixing flameproof (FLP/WP) three pole and neutral lighteing distribution panel 08 Way incl incoming MCB 4 pole 'C' curve 63 Amps -01 No. and outgoing MCB SP 'C' 6 Amp-24 Nos with complete internal bus bar and wiring up terminals complete incl dismantling and taking down old u/s DB normal / Flameproof any type any capacity as per actual available at site complete all as specified and directed. Note: MCBs shall be deemed to be included in unit rate quoted without any extra charge.
18Supply and fixing flameproof (FLP/WP) exhaust fan 18\\", 0.25HP, single Phase complete incl dismantling and taking down old u/s exhaust fan any type any size as per actual available at site complete all as specified and directed. Note: Old u/s material shall be the property of department and shall be deposited in MES store yard.
19Supply and fixing flameproof (FLP/WP) wall mounted fan 18\\", 0.25HP, Single Phase complete incl dismantling and taking down old u/s wall mounted fan any type any size as per actual available at site complete all as specified and directed. Note: Old u/s material shall be the property of department and shall be deposited in MES store yard.
20Supply and fixing flameproof (FLP/WP) pedestal Fan 18\\", 0.25HP, Single Phase complete incl dismantling and taking down old u/s pedestal fan any type any size as per actual available at site complete all as specified and directed. Note: Old u/s material shall be the property of department and shall be deposited in MES store yard.
21Supply and fixing online UPS of capacity 20 KVA, 3-Phase In/Out configuration, inbuilt isolation transformer (i) Input (AC)- nominal voltage 400 V three phase / 230 V single phase, voltage range -20%+15%, Frequency 50Hz/60 Hz (autosensing), Power Factor > 0.99 from 50% to 100% of nominal load, (ii) Output with mains (AC-AC) - nominal voltage 400 V three phase, Nominal Power 20 KVA, Frequency 50Hz/60 Hz (autosensing) synchronized with input frequency or 1% tolerance, ( (iii) Output in battery Run (DC - AC) - nominal voltage 400 V three phase, Nominal Power 15 KVA, Frequency 50Hz/60 Hz (autosensing) synchronized with input frequency or 1% tolerance, suitable for lead Acid, sealed, maintenance free batteries, nominal UPS battery volatge 324 Volt DC, IP21, with advance battery charger, booster, rectifier/PFC, Maintenance Bypass arrangement, control panel and digital display, Input/Output connections 3P+N+PE connectors on omega bar complete all as specified and directed.
22Supply and fixing sealed maintenance free Battery 12 Volt 75 AH (SMF/VRLA) complete all as specified and directed.
23Material and labour for earthing complete with copper earth electrode 60cmx60cmx3.15mm thick surrounded by char coal and salt buried directly in ground vertically in pit of depth not less then 2.25 m below ground level with top edge of the earth plate at depth of not less then 1.5 m below ground level surrounded from all sides by char coal dust and common salt in alternate layers of 15 cm depth and earth plate electrode connected to copper earth strip 20x3 mm at two points by means of GI nuts bolts, check nuts and washers and connected to earthling test point drawn through 40 mm dia GI pipe for protection pipe incl PCC earth pit (1:3:6) type C-2 with CI frame and RCC cover all as shown in electrical Plate No 3 on SSR Part-I including testing and dismantling ,taking down old unser earthing complete all as specified and directed. Note: (i) Rate of Earth work, Earthing electrode, all connections, nut-bolts, washers, complete labour, testing, Earth lead upto 7.5 m, char coal dust, common salt, porcelain insulator,PCC earth Pit, RCC cover, funnel with wire mesh shall deemed to be included in the unit rate quoted and watering pipe, earth lead protection pipe, test poit, and earth lead exceeding 7.5 m shall be measured and paid for separately.
24Supply, fixing & laying GI tubing light grade 20 mm dia used aswater pipe or protection pipe for earth lead wire in earthing or alongwith pole / wall/ culvert / drainage etc for mechanical protection of cable complete all as specified and directed. Note: All required items and accessories , bend, joints, nut bolts, clamps etc shall deemed to be included in the unit rate quoted.
25Supply , fixing & laying GI tubing light grade 40 mm dia used as protection pipe for earth lead strip in earthing or alongwith pole / wall/ culvert / drainage etc for mechanical protection of cable complete all as specified and directed. Note: All required items and accessories , bend, joints, nut bolts, clamps etc shall deemed to be included in the unit rate quoted.
26Supply and fixing earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 20x3 mm dia copper strip complete all as specified and directed.
27Supply and fixing test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw complete all as specified and directed.
28Material and labour for cutting brick wall, making a holl suitable for fixing exhaust fan of sweep upto 600 mm and making good distyrbed surface complete all as specified and directed. Please Enable Macros to View BoQ information

Other Detail

Information Source https://defproc.gov.in/nicgep/app
Download FileName File Description File Size
Download a8e79ce6-e91b-417e-a2ac-d35a8c28eb55.html Tender Documents 0 KB
Download BOQ_863477.xls Tender Documents 0 KB
Download Tenderdocuments12.pdf Tender Documents 0 KB
Download Tendernotice_1.pdf Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.