| 1 | Repair of 200 KVA Servo Stabilizer (Detailed Item Description): Repair, servicing, and complete overhauling of 200 KVA Servo Stabilizer including body work with strengthening/repair of main frame, fabrication and fixing of inbuilt panel for bypass arrangement comprising of 400 Amp bypass switch and 300 Amp contactor. The scope shall also include replacement /repair of internal components such as arm bush, top bush, carbon brushes, copper reaping arm (35 sq.mm), and central cords of all phases.Further, the work includes rewinding of all three phases (as required), repair/servicing of buck-boost transformer, oil topping (if required), proper insulation, alignment, testing, and commissioning of the stabilizer.The item also includes complete dismantling, loading, transportation to workshop, unloading, repair, re-installation at site, testing, and commissioning, along with all consumables, labour, tools & tackles required for satisfactory operation of the system. |
| 2 | Dismantling of existing 11 mtr electric pole, shifting to new approved location, excavation of pit, providing and laying PCC (1:3:6) foundation, erection in proper alignment, refixing of all existing fittings, backfilling, ramming and curing, complete in all respects as per directions of Engineer-in-Charge. |
| 3 | Repair of installed automatic dome sensor door by way of replacement of defective controlling transformer/motor, belt, sensors, and servicing including proper balancing of doors, greasing of belt and allied components, complete in all respects as per directions of Engineer-in-Charge. |
| 4 | Repairing Cable with Cable sleeves with cotton blade, Pvc tape, tube joint, thimbles, Joint Kit etc as per requirement at site and as per the instructions of Engineer-in-Charge. |
| 5 | Repair of non-functional 20 KVA Capacitor Bank by way of replacement of defective condenser (capacitor unit) including allied works i.e. a, Dismantling of the existing defective capacitor (condenser) from the capacitor bank panel.b, Supply and installation of suitable 20 KVA rated capacitor unit (as per existing system specification).c, Checking and tightening of all electrical connections, contactors, fuses, and terminals.d, Replacement of minor accessories (lugs, thimbles, nuts/bolts, insulating materials, etc.) as required.e, Testing of capacitor bank for proper functioning, power factor improvement, and load balancing.f, Recommissioning of the capacitor bank after repair.g, Disposal of unserviceable capacitor as per norms. |
| 6 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. Group-A |
| 7 | Wiring for light point/ fan point / exhaust fan point/ call bell point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, with modular switch, modular plate, suitable GI box earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc as required (Partially laid conduit) |
| 8 | Wiring for light point/ fan point / exhaust fan point/ call bell point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC casing & capping, with modular switch, modular plate, suitable PVC box earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc as required |
| 9 | Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable as earth wire in existing surface/recessed steel/PVC conduit including dismantling as required. Group A |
| 10 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. |
| 11 | Supplying and fixing suitable size PVC box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. |
| 12 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 6 pin 5/6 amps & 15/16 amps. modular socket outlet and 15/16 amps modular switch connection etc. as required. |
| 13 | Supplying and fixing suitable size PVC box with modular plate and cover in front on surface or in recess including providing and fixing 6 pin 5/6 amps & 15/16 amps. modular socket outlet and 15/16 amps modular switch connection etc. as required. |
| 14 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings). |
| 15 | Supplying and fixing suitable size PVC box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings). |
| 16 | Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25/20 A modular socket outlet and 25/32 A modular SP MCB, \\"C\\" curve including connections, painting etc. as required. |
| 17 | Supplying & fixing suitable size PVC box wih modular plate and cover in front on surface or in recess including providing and fixing 25/20 A modular socket outlet and 25/32 A modular SP MCB, \\"C\\" curve including connections, painting etc. as required. |
| 18 | Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25/20 A modular socket outlet and 25/32 A modular DP MCB, \\"C\\" curve including connections, painting etc. as required. |
| 19 | Supplying & fixing suitable size PVC box wih modular plate and cover in front on surface or in recess including providing and fixing 25/20 A modular socket outlet and 25/32 A modular DP MCB, \\"C\\" curve including connections, painting etc. as required. |
| 20 | Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25/20 A modular socket outlet and 25/32 A modular DP switch with indicator, including connections, painting etc. as required. |
| 21 | Supplying & fixing suitable size PVC box wih modular plate and cover in front on surface or in recess including providing and fixing 25/20 A modular socket outlet and 25/32 A modular DP switch with indicator, including connections, painting etc. as required. |
| 22 | Supplying and fixing metal box of 150mm X 75mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 A socket outlet and 5/6 A piano type switch, connections, painting etc. as required |
| 23 | Supplying and fixing metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 A socket outlet and 15/16 A piano type switch, connections, painting etc. as required. |
| 24 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 25 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 26 | Wiring for circuit/ sub-main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed PVC conduit as required. |
| 27 | 2 x 1.5 Sq.mm + 1 x 1.5 Sq.mm earth wire |
| 28 | 2 x 2.5 sq mm + 1 x 2.5 sq. mm earth wire |
| 29 | 2 x 4 sq. mm + 1 x 4 sq. mm earth wire |
| 30 | 2 x 6 sq. mm + 1 x 6 sqmm earth wire |
| 31 | 2 x 10 sq. mm + 1 x 6 sq. mm earth wire |
| 32 | 2 x 16 sq. mm + 1 x 6 sq. mm earth wire |
| 33 | 4 X 2.5 sq. mm + 2 X 2.5 sq. mm earth wire |
| 34 | 4 X 4 sq. mm + 2 X 4 sq. mm earth wire |
| 35 | 4 X 6 sq. mm + 2 X 6 sq. mm earth wire |
| 36 | 4 x 10 sq. mm + 2 x 6 sq. mm earth wire |
| 37 | 4 x 16 sq. mm + 2 x 6 sq. mm earth wire |
| 38 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor single core cable in the existing surface/recessed steel/PVC conduit as required. |
| 39 | 1 x 1.5 sq. mm |
| 40 | 2 x 1.5 sq. mm |
| 41 | 3 x 1.5 sq. mm |
| 42 | 1x 2.5 sq. mm |
| 43 | 2 x 2.5 sq. mm |
| 44 | 3 x 2.5 sq. mm |
| 45 | 1 x 4 sq. mm |
| 46 | 2 x 4 sq. mm |
| 47 | 3 x 4 sq. mm |
| 48 | 4 x 4 sq. mm |
| 49 | 5 x 4 sq. mm |
| 50 | 6 x 4 sq. mm |
| 51 | 1 x 6 sq. mm |
| 52 | 2 x 6 sq. mm |
| 53 | 3 x 6 sq. mm |
| 54 | 4 x 6 sq. mm |
| 55 | 5 x 6 sq. mm |
| 56 | 6 x 6 sq. mm |
| 57 | 1 x 10 Sq mm |
| 58 | 2 x 10 Sq mm |
| 59 | 3 x 10 Sq mm |
| 60 | 4 x 10 Sq mm |
| 61 | 1 x 16 Sq mm |
| 62 | 2 x 16 Sq mm |
| 63 | 3 x 16 Sq mm |
| 64 | 4 x 16 Sq mm |
| 65 | Supplying and drawing following pair 0.5 mm dia FRLS PVCinsulated annealed copper conductor, unarmored telephonecable in the existing surface/ recessed steel/ PVC conduit as |
| 66 | 1 Pair |
| 67 | 2 Pair |
| 68 | 4 Pair |
| 69 | Supplying and fixing of ceiling fan of following sweep with 2.25 mfd condenser and 1'-6\\" down rod on the existing fan hook with necessary connection from ceiling rose to fan using twin core copper wire. (As approved site in-charge) |
| 70 | 900 mm sweep (1Star) |
| 71 | 900 mm sweep (3Star) |
| 72 | 1200 mm sweep |
| 73 | 1200 mm sweep (1 Star) |
| 74 | 1200 mm sweep (3 Star) |
| 75 | 1400 mm sweep (3 Star) |
| 76 | 1200 mm sweep Decorative Fan as approved site engineer |
| 77 | 1200 mm sweep Aero Dynamic type (Silent) (Aero Quiet) as approved site engineer (3 Star) |
| 78 | 1200 mm sweep BLDC Decorative Fan with remote as approved site engineer (5Star) |
| 79 | Supplying & fixing of Pedestal Fan 400 mm (3Star) |
| 80 | Pedestal Fan |
| 81 | Pedestal Fan With Remote |
| 82 | Supplying and fixing of 400 mm sweep wall mounting fan (oscillating type) on wall with necessary connection as required. (3Star) |
| 83 | Supplying and fixing of 450 mm sweep wall metalic blade Heavy Duty mounting fan (oscillating type) on wall with necessary connection as required. (3Star) |
| 84 | Supplying and fixing of following sizes Transair exhaust fan with metal blade complete set on existing holes on wall with necessary connection from ceiling rose to fan using 2 core flexible copper wire. |
| 85 | 200 mm / 8\\" sweep exhaust fan |
| 86 | 225 mm / 9\\" sweep exhaust fan |
| 87 | 300mm/12\\" sweep exhust fan |
| 88 | 300mm/12\\" sweep exhust fan (Heavy Duty) |
| 89 | 380mm/15\\" Heavy duty |
| 90 | 450 mm/18\\" Heavy duty |
| 91 | Supplying and fixing of following sizes exhaust fan with PVC blade & Louvers complete set on existing holes on wall with necessary connection from ceiling rose to fan using 2 core flexible copper wire. |
| 92 | 150 mm / 6\\" sweep exhaust fan |
| 93 | 200 mm / 8\\" sweep exhaust fan |
| 94 | 225 mm / 9\\" sweep exhaust fan |
| 95 | 250 mm /10\\" sweep exhaust fan |
| 96 | 300mm/12\\" sweep exhust fan |
| 97 | Supplying and fixing of fan hook (U hook) on celiling with 4 nos. of anchor fastener on both ends with necessary bolts and nuts and mansonry work as required. |
| 98 | Supplying and fixing of following sizes extra down rod with twin core flexible copper wire for ceiling fan. |
| 99 | 1'-0\\" |
| 100 | 1'-6\\" |
| 101 | 2'-0\\" |
| 102 | 3'-0\\" |
| 103 | 4'-0\\" |
| 104 | 6'-0\\" |
| 105 | Making round shaped hole on the wall including supply and fixing of necessary cement concrete collar to suit 300 mm heavy duty exhaust fan and finishing the wall to make good. |
| 106 | Supplying and fixing of 25 mm thick ply wood with round shaping at the center to fix exhaust fan on ventilator with required accessories. |
| 107 | Supplying & fixing of following way single pole and netural, sheet steel, MCB distribution board, 240 volts, on surface/ recess complete with tinned copper busbar netural busbar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (IP43) |
| 108 | 4 way (Double door) |
| 109 | 6 way (Double door) |
| 110 | 8 way (Double door ) |
| 111 | 12 way (Double door) |
| 112 | 16 way (Double door) |
| 113 | Supplying & fixing of following way horizontal type three pole and netural, sheet steel, MCB distribution board, 415 volts, on surface/ recess complete with tinned copper bus bar neutral buss bar, earth bar,din bar interconnection nection,powder painted including earthing etc. as required. (IP43) |
| 114 | 4 Way (4+12), (Double door ) (TPN type) |
| 115 | 6 way ( 4+18), (Double door) (TPN type) |
| 116 | 8 way (4+24), (Double door) (TPN type) |
| 117 | 12 way (4 +36), (Double door) (TPN type) |
| 118 | Supply, installation, testing & commissioning of GI Electrode Earthing with 50mm dia and 3 meter length, with 3mm thick the electrode should be hot-dip galvinised. The GI Electrode shall be pre-filled with Cristaline Conductive Materila (CCM). The GI electrode shall be surrounded with BEE MOIST compound to provide maximum contact betwen the electrode and compound should be eco-friendly GI Electrode Earthing should be maintinance free and does not require regular manual addition of water . The earthing pit should be covered with PVC cover. |
| 119 | Supply, installation, testing & commissioning of GI Electrode Earthing with 50mm dia and 2 meter length, with 3mm thick the electrode should be hot-dip galvinised. The GI Electrode shall be pre-filled with Cristaline Conductive Materila (CCM). The GI electrode shall be surrounded with BEE MOIST compound to provide maximum contact betwen the electrode and compound should be eco-friendly GI Electrode Earthing should be maintinance free and does not require regular manual addition of water . The earthing pit should be covered with PVC cover. |
| 120 | Earthing with copper earth plate 600 mm X 600 mm X 3 mmthick including accessories, and providing masonry enclosurewith cover plate having locking arrangement and watering pipeof 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 121 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 122 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. |
| 123 | Providing and fixing 20 mm X 3 mm G.I. strip on surface or in recess for connections etc. as required. |
| 124 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. |
| 125 | Supply, installation, testing & commissioning of maintenance free copper earthing system with 3 mtrs. Electrode 40 mm dia with minium 2mm thick and does not require manual additional of water. The electrode shall be pre-filled with hygroscopic powder and provided with suitable breathing and leaching ports at the ends. the electrode shall be surrounded by suitable powdered form of BEE MOIST so as to provide maximum contact between the electrode and the compund. The compound should be eco-friendly The earthing pit should be covered with PVC cover. |
| 126 | Supply, installation, testing & commissioning of maintenance free copper earthing system with 2 mtrs. Electrode 40 mm dia with minium 2mm thick and does not require manual additional of water. The electrode shall be pre-filled with hygroscopic powder and provided with suitable breathing and leaching ports at the ends. the electrode shall be surrounded by suitable powdered form of BEE MOIST so as to provide maximum contact between the electrode and the compund. The compound should be eco-friendly The earthing pit should be covered with PVC cover. |
| 127 | Providing and fixing of 25 mm x 5 mm copper strip on surface or in recess for connections etc. as required. |
| 128 | Providing and fixing of 20 mm x3 mm copper strip on surface or in recess for connections etc. as required. |
| 129 | Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required. |
| 130 | Supplying and fixing of following sizes of PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required. (ISI Make). |
| 131 | 20 mm |
| 132 | 25 mm |
| 133 | 32 mm |
| 134 | 40 mm |
| 135 | 20/25 mm flexible pipe |
| 136 | Supplying and fixing of Following light fitting with lamps on ceiling/ wall with necessary connection from ceiling rose to fitting by twin core flexible copper wire. |
| 137 | IP20 SMD Mid Power LED batten type integrated light fixture made from Powder coated Extruded aluminium housing with in built driver , System lumen efficacy ≥ 110 lm/Watt output, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, CRI >80 , life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , Maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted. All as per pre approved by Engineer in charge. 20/22 watt LED 4 feet with min. lumen output (2000- 2200) lm |
| 138 | Supplying, Installation, Testing & Commissioning of 18- 22 Watt LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140- 270 Volt, frequency 50/60 hz, Operating temp range -5 °C to 40 °C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10%, P. F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-inCharge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm) |
| 139 | 20/22 watt LED 4 feet tube light fitting/fixture PVC housing with 2000 Lumens and min lumens efficiency 110 lumens/watt P.F >.90. having 50000 hours. |
| 140 | 28 watt LED 4 feet tube light fitting/fixture Aluminium housing with 2800 Lumens and min lumens efficiency 110 lumens/watt P.F >.90. |
| 141 | 36 watt LED 4 feet tube light fitting/fixture Aluminium housing with 3600 Lumens and min lumens efficiency 110 lumens/watt P.F >.90. |
| 142 | Decorative LED Hanging Light for officer table as apporved by site Engineer |
| 143 | LED Batten Tube fitting 600mm size 10/11 watt Aluminium housing with 1000 Lumens and min lumens efficiency 100 lumens/watt P.F >.90 . |
| 144 | 36 wattPanel light 2x2 ft., of following body material andconstruction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operatingvoltage AC 140-270 Volt, frequency 50/60 hz,Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuitprotection, THD < 10% , P. F.≥0.95, IP20, CRI >80,UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED, Driver& electrical circuitry), of minimum 50000 BurningHours with, 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11report, CCT 3000°K / 4000°K / 5700°K/6500°K (As per ANSI Bin), SDCM(StandardDeviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder Coated CRCA Sheet Body (Thickness > 0.50 mm) |
| 145 | Industrial surface/suspension general purpose 36/40 watt LED Batten 4 ft Light powder coated aluminium housing with integrated electronic diode with luminius efficancy > 120 (LM 79, 80 certified IP40 THD:<10% P. F.≥0.95, CRI >80 , life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , Maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted. All as per pre approved by Engineer in charge. |
| 146 | 36 watt 4 x 1 ft Environmental friendly, new generation, aesthetically desigened, ultra modern recess mounting luminaire with hig brightness SMD LEDs as light source, suitable for Armstrong/Grid ceiling HET PMMA diffuser with minimum system lumen efficacy of 110 lm/W and minimum 3900 lumens with CRCA housing with APFC constant Current driver for proper driving of LEDs and P.F.>0.95 with THD<10% ,CRI 80.The LED with life of 50000 Hrs at L70. The LEDs used in the luminaire shall have CCT of 5700K- 6500K with CRI of minimum 80. The Input voltage range shall be 150V to 270V .The Fixture should have In-built Surge Protection of 3kV. Certification:- LM79 & LM80 test report should be from govt approved Inhouse NABL lab/ government of India authorised lab. |
| 147 | Mirror light LED fitting with 9/11W LED lamp |
| 148 | Water tight bulk head LED fitting with 10 watt LED lamp. |
| 149 | Providing and fixing of LED Lamp. |
| 150 | 0.5 w |
| 151 | Providing and fixing of E-27/14 LED Light |
| 152 | 9 watt (warm) |
| 153 | 9 watt (White) |
| 154 | 12 watt (warm) |
| 155 | 12 watt (White) |
| 156 | 20 watt (warm) |
| 157 | 20 watt (White) |
| 158 | Supplying, installation, Testing & Commissioning of Street light LED fixture powder coated pressure die cast aluminium body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10/8, CRI >70, under voltage and over voltage protection, EMIEMC As per CISPR -15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life endsas per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin),SDCM (Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copperconductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C) |
| 159 | 40 watt |
| 160 | 45 watt |
| 161 | 50 watt |
| 162 | 70 watt |
| 163 | 90 watt |
| 164 | 100 watt |
| 165 | 120 watt |
| 166 | 150 watt |
| 167 | 180 watt |
| 168 | 200 watt |
| 169 | Supplying, Installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver asper the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10/8, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR -15, lenses for beam angle 30 deg-120deg as per the application and theproject requirement., suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin) , SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-inCharge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). |
| 170 | 50 watt |
| 171 | 70 watt |
| 172 | 90-100 watt |
| 173 | 120-150 watt |
| 174 | 200 watt |
| 175 | 250 watt |
| 176 | 350 watt |
| 177 | Supplying, Installation, Testing & Commissioning of LED Recessed/ surface Down lighter (Round/ square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -50C to 400C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5%), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K /4000°K / 5700°K / 6500°K (As per ANSI Bin), SDCM (Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be confirming to relevant BIS standards. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 and <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C) Powder coated die cast /Extruded aluminium Body including trim |
| 178 | 5- 7watt. |
| 179 | 8-10watt. |
| 180 | 12-15 watt. |
| 181 | 18-20 watt. |
| 182 | 22-26 watt. |
| 183 | 28- 30 watt. |
| 184 | Providing & fixing of following accessories. |
| 185 | 5/6 Amp. 3 pinTop |
| 186 | 5/6 Amp 2 pin Top |
| 187 | 15/16 Amp 3 pin top |
| 188 | Insulation Tape (ISI brand) |
| 189 | Electronic Step Type fan Regular (Piano type) |
| 190 | Celing Rose |
| 191 | 2.2/3/3.5 mfd fan condenser |
| 192 | Brass batten/ angle holder including (Modular)connection etc. as required. |
| 193 | Dimmer Type Regulator (with numbering) |
| 194 | 5/6 Amp combined |
| 195 | 15/16 Amp combined |
| 196 | Toolkit comprises of plier, screw driver and Phase tester |
| 197 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required. |
| 198 | 1 or 2 Module (75mm x 75mm) |
| 199 | 3 Module (100mm x 75mm) |
| 200 | 4 Module (125mm x 75mm) |
| 201 | 6 Module (200mm x 75mm) |
| 202 | 8 Module (125mm x125mm) |
| 203 | 12 Module ( 200mm x 150mm) |
| 204 | 18 Module |
| 205 | Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required. |
| 206 | 1 or 2 Module |
| 207 | 3 Module |
| 208 | 4 Module |
| 209 | 6 Module |
| 210 | 8 Module |
| 211 | 12 Module |
| 212 | 18 Module |
| 213 | Supplying and fixing following size/ modules, GI box in recess etc as required. |
| 214 | 1 or 2 Module (75mm X 75mm) |
| 215 | 3 Module (100mm X 75mm) |
| 216 | 4 Module (125mm X 75mm) |
| 217 | 6 Module (200mm X 75mm) |
| 218 | 8 Module (125mm X 125mm) |
| 219 | 12 Module (200mm X 150mm) |
| 220 | 18 Module |
| 221 | Supplying and fixing following size/ modules, PVC box in recess/surface etc as required. |
| 222 | 1 or 2 Module (75mm X 75mm) |
| 223 | 3 Module (100mm X 75mm) |
| 224 | 4 Module (125mm X 75mm) |
| 225 | 6 Module (200mm X 75mm) |
| 226 | 8 Module (125mm X 125mm) |
| 227 | 12 Module (200mm X 150mm) |
| 228 | 18 Module |
| 229 | Suplying and fixing following modular switch/ socket on the existing modular plate & switch box inculding connection but excluding modular plate etc. as required. |
| 230 | 5/6 amps switch |
| 231 | 2 way 5/6 amps switch |
| 232 | 15/16 amp switch |
| 233 | 3 pin 5/6 amp socket outlet |
| 234 | 6 pin 15/16 socket outlet |
| 235 | Telephone socket outlet |
| 236 | TV Antenna socket outlet |
| 237 | DP Switch 32 Amp with Indicator |
| 238 | Bell push |
| 239 | 2 pin socket outlet 5 Amp. |
| 240 | Rewinding of the following fans using enameled copper wire of required gauage, varnishing oiling greasing etc. The workmanship shall up to the satisfaction of the Engineer in charge. |
| 241 | 900mm /1200mm / 1400mm sweep AC ceiling fan |
| 242 | upto 300mm sweep exchaust fan |
| 243 | Servicing of the Geyser etc. as required. |
| 244 | Supplying and replacement of the suitable size and rating of the following in the storage water heater and making the geyser in good working condition. (Make as per the gyser installed) |
| 245 | Heating Element |
| 246 | Thermostat with control |
| 247 | Replacement of Assembly complete job |
| 248 | Supplying and fixing of following rating 240/415 volts \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 249 | Single pole upto 32 amp. |
| 250 | Single pole 40 amp. |
| 251 | Single pole and neutral upto 32 amp. |
| 252 | Single pole and neutral 32 amp. (Modular) |
| 253 | Double pole upto 32 amp. |
| 254 | Double pole 40 amp. |
| 255 | Triple Pole upto 32 amp. |
| 256 | Triple Pole 40 amp. |
| 257 | Triple Pole and netural upto 32 amp. |
| 258 | Four Pole upto 32 amp. |
| 259 | Single pole and neutral 40 Amp |
| 260 | Single pole and neutral 63 Amp |
| 261 | Single pole and neutral 100 Amp |
| 262 | TPN 40 Amp |
| 263 | TPN 63 Amp |
| 264 | TPN 100 Amp |
| 265 | FPN 40 Amp |
| 266 | FPN 63 Amp |
| 267 | FPN 100 Amp |
| 268 | SPDs T1 + T2 - 12.5 KA Cat Nos. 4122 70/71/72/73/76/77 |
| 269 | SPD 1P+N Right 25 KA |
| 270 | SPD 1P Right 12.5 KA |
| 271 | 2P 25 KA |
| 272 | 3P 37.5 KA |
| 273 | 4P 50 KA |
| 274 | Supplying and fixing single pole blanking plate in the existing MCB DB Complete etc. as required |
| 275 | SITC of wall/free standing floor mounted dust and vermin proof compartmentalized cubical panel for electrical Works, made out of CRCA sheet. Other parameters required as per point (a) Thickness of sheet shall not be less than 1.6 mm up to 600 mm length/width of any compartment and be of 2.0 mm above 600 mm. Load bearing structure shall be of 2.0 mm thick sheet supported by base M.S. channel if required. Side walls and cable alley compartment shaving bolted type doors with/without detachable extension type structure (b) Panel shall be duly treated for derusting in 7 tank process with de phosphating and with powder coating of minimum 70 microns on both side of panel in desired shade The panel having PU/Neoprene rubber gasket of not less than 3mm thickness, required hardware, separate detachable gland plate M.S. base channel (min 75mm), hinged door with locking arrangement for equipment/switchgear c) Interconnection between bus bar and switch gears/cable shall be rigidly supported and made out by flexible copper wires (upto 125 amp) and by solid bus bar (> 125). (d) Only outer area on all sides shall be measured & panel to be fabricated only from CPRI approved fabricator CPRI Test certificates to be submitted) All as per pre approved by Engineer in charge. |
| 276 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. (Thermal Magnetic type, Adjustable type) |
| 277 | 40 Amp, 25 KA, FP MCCB ICU = 100% ICS |
| 278 | 63 Amp, 25 KA, FP MCCB ICU = 100% ICS |
| 279 | 100 Amp, 30 KA, FP MCCB ICU = 100% ICS |
| 280 | 125 Amp, 36 KA, FP MCCB ICU = 100% ICS |
| 281 | 160 Amp, 36 KA, FP MCCB ICU = 100% ICS |
| 282 | 200 Amp, 36 KA, FP MCCB ICU = 100% ICS |
| 283 | 250 Amp, 36KA, FP MCCB ICU = 100% ICS |
| 284 | 320 Amp, 36 KA, FP MCCB ICU = 100% ICS |
| 285 | 400 Amp, 50 KA, FP MCCB ICU = 100% ICS |
| 286 | 630 Amp, 50 KA, FP MCCB ICU = 100% ICS |
| 287 | Electrical Rubber Mat having thickness 6mm and width 1 Mtr |
| 288 | ON Load Change Over Switch FP 100 amp. (Front operated) |
| 289 | ON Load Change Over Switch FP 200 amp. (Front operated) |
| 290 | ON Load Change Over Switch FP 250 amp. (Front operated) |
| 291 | ON Load Change Over Switch FP 320/315 amp. (Front operated) |
| 292 | ON Load Change Over Switch FP 400 amp. (Front operated) |
| 293 | Aluminium Bus Bar 100 Amp set of 4 strips 18\\" |
| 294 | Aluminium Bus Bar 200 Amp set of 4 strips 18\\" |
| 295 | Aluminium Bus Bar 300 Amp set of 4 strips 18\\" |
| 296 | Aluminium Bus Bar 400 Amp set of 4 strips 18\\" |
| 297 | Aluminium Bus Bar 500 Amp set of 4 strips 18\\" |
| 298 | Aluminium Bus Bar 800 Amp set of 4 strips 18\\" |
| 299 | Digital Metering devices, comprising of Voltmeter, Ammeter, Selector Switch, Indicating Lamp, CT Set etc. |
| 300 | Providing and fixing of PCB in wall fans (Remote control type) having sweep 400 mm of make Havells/ CG. |
| 301 | Providing and fixing of blades of following fans |
| 302 | Wall Fan |
| 303 | Ceiling Fan |
| 304 | Exhaust Fan |
| 305 | Pedestal Fan |
| 306 | Supplying & laying of PVC insulated and PVC sheathed/ XLPE Aluminium power cable of 1.1 KV grade of following size on surfaces/ direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. (Armoured cable) |
| 307 | 10 sq. mm 2 core |
| 308 | 16 sq. mm 2 core |
| 309 | 25 sq. mm 2 core |
| 310 | 35 sq. mm 2 core |
| 311 | 10 sq. mm 4 core |
| 312 | 16 sq. mm 4 core |
| 313 | 25 sq. mm 4 core |
| 314 | 25 sq. mm 3.5 core |
| 315 | 35 sq. mm 3.5 core |
| 316 | 50 sq. mm 3.5 core |
| 317 | 70 sq. mm 3.5 core |
| 318 | 95 sq. mm 3.5 core |
| 319 | 120 sq. mm 3.5 core |
| 320 | 150 sq. mm 3.5 core |
| 321 | 185 sq. mm 3.5 core |
| 322 | 240 sq. mm 3.5 core |
| 323 | 300 sq. mm 3.5 core |
| 324 | 400 sq. mm 3.5 core |
| 325 | 500 sq. mm 3.5 core |
| 326 | 630 sq. mm 3.5 core |
| 327 | Supplying and fixing of twin core aluminium cable all along the wall surface unarmoured. |
| 328 | 6 sq. mm |
| 329 | 10 sq. mm |
| 330 | 16 sq.mm |
| 331 | 25 sq.mm |
| 332 | 35 sq.mm |
| 333 | Supplying and fixing of Service line twin core PVC insulated aluminium cable all along the wall surface unarmoured. |
| 334 | 10 sq. mm |
| 335 | 16 sq.mm |
| 336 | Flexible Twin core cable whiter wire |
| 337 | Labour charge for electrician |
| 338 | Labour charge for Helper electrician |
| 339 | Supplying & Drawing of Co- axial TV cable RG-6 grade, 0.7 mm solid copper conductor. |
| 340 | Supplying, drawing, Testing and commissioning of Cat 6A UTP 4 pair, 23 AWG solid copper cable in existing conduit/ on surface, U/FTP, LSZH, NonPlenum, Horizontal (solid) Cable suitable for high speed data networking application supporting upto 10Gbps over a 100 meter channel. The 4 Unshielded Twisted Pairs (UTP) cable with color coded insulation for easy indentification should have FLAME PROPERTIES i.e. Flammability Test - IEC 60332-1, Smoke Density - IEC 61034, LSZH standards compliance: ANSI/TIA-568 C.2, ISO/IEC 11801, IEEE 802.3an, RoHS. Delay Skew should be < 45NS. The outer Cable Diameter should be 7.5 + 2 mm. Cable should have been tested and verified by UL/ ETL etc. complete as required. |
| 341 | Supplying, drawing, Installation, Testing and commissioning of CAT6 UTP LSZH 23AWG Twisted Pair Cable in existing conduit/ on surface, Category 6 Unshielded Twisted Pair, 4 pair should be complied as per UL/ETL verification program for compliance with ANSI/TIA-568.2-D standard. Outer diameter should be in the range of 6.1mm nominal with Operating Temperature Range : -5° to +60°C, Bending Radius : < 4 X Cable Diameter at –5°C ± 1°C and Pulling Force: 11.5Kg etc. complete as required. |
| 342 | Supplying & fixing of following Remote Bells |
| 343 | Bell controlled by Single Remote with minimum 15 mtrs range |
| 344 | Call bell / Buzzer, Single phase with minimum 15 mtrs range |
| 345 | Bell controlled by double remote with minimum 15 mtrs range |
| 346 | Ding Dong Bell |
| 347 | Supplying & fixing of following PVC Gang Box. |
| 348 | One way |
| 349 | Two way |
| 350 | 1 + 1 way |
| 351 | 3 + 1 way |
| 352 | 4 + 1 way |
| 353 | 6 + 1 way |
| 354 | 1 + 1 way (Power) |
| 355 | Supplying & fixing of Electrical Accessories PVC Casing and Caping (Batten). |
| 356 | Casing Caping 1\\" |
| 357 | Casing Caping 3/4\\" |
| 358 | Casing Caping 1' 1/4\\" |
| 359 | Casing Caping 1' 1/2\\" |
| 360 | Casing Caping 1' 3/4\\" |
| 361 | 4\\" Deep Box |
| 362 | 5\\" Fan Box |
| 363 | Conceeled Box |
| 364 | Junction Box (Metal) |
| 365 | Supplying and fixing of Phenolic Laminated Sheet 9\\" x 11\\" including cutting the space for switches/socket etc. |
| 366 | Supplying and fixing of Phenolic Laminated Sheet 9\\" x 6\\" including cutting the space for switches/socket etc. |
| 367 | Supplying and fixing of Phenolic Laminated Sheet 4\\" x 4\\" including cutting the space for switches/socket etc. |
| 368 | Supplying and fixing of Phenolic Laminated Sheet 11\\" x 13\\" including cutting the space for switches/socket etc. |
| 369 | Supplying and fixing of Phenolic Laminated Sheet 6\\" x 3\\" including cutting the space for switches/socket etc. |
| 370 | Dismentalling of Ceiling fan/Wall fan/Exhaust fan and re-fixing the same after repair. |
| 371 | Repair of fan by way of replacing damaged bearing, bushes etc as required. |
| 372 | Supply of following items |
| 373 | Invertor Sinewave 850-950 VA |
| 374 | Invertor Sinewave 1050-1100 VA |
| 375 | Invertor Sinewave 1650-1850 VA |
| 376 | Invertor Sinewave 2000-2200 VA |
| 377 | Supplying & fixing of Battery 12 Volt. Tubular 150 AH with 36 months Guarantee Note.:- (Rs.2500 /Battery has to be deduct for the scrap of old batteries (150 AH) from allotted rate in case of replacement of battery is out of warranty period. |
| 378 | Supplying & fixing of Battery 12 Volt. Tubular 200 AH with 36 months Guarantee Note.:- (Rs.2500 /Battery has to be deduct for the scrap of old batteries (150 AH) from allotted rate in case of replacement of battery is out of warranty period. |
| 379 | Supplying & fixing of PVC Trolley for housing single battery inverter |
| 380 | Supplying & fixing of PVC Trolley for housing double battery inverter |
| 381 | Repair to PCB of inverter |
| 382 | 850 VA to 1050 VA |
| 383 | 1550 VA to 2000 VA |
| 384 | Replacement of PCB of inverter |
| 385 | 850 VA to 1050 VA |
| 386 | 1550 VA to 2000 VA |
| 387 | Repair of Automatic Voltage Stabilizer by way of copper winding etc as required. |
| 388 | upto 3 KVA |
| 389 | Above 3KVA to 5 KVA |
| 390 | Supplying Installation Testing and Commissioning of 2 MP IP IR Dome/Bullet Camera having following specifications, type of lens and features etc :-1) Signal System: PAL/NTSC, Signal to Noise Ratio: >50 dB, Camera should display Camera title, Date & Time in live & recorded video2)Image Sensor: 1/2.8\\" or better progressive Scan CMOS to get color image even at nightcondition(Minimum Illumination: 0.006 Lux@ F1.4, AGC ON, 0 lux with IR or better) True Day & Night High Performance Mechanical IR cut filter with auto switch, Integrated IR Source (Auto, Manual)- Inbuilt IR LED's with effective distance upto 50 meter or better and 30 meter for colour view in night, Imaging: 1/3s to 1/30000s electronic shutter support, Auto Gain Control , White Balance- Auto, Back Light Compensation, Multi zone Privacy Masking, HLC, Digital Watermarking.3) Compression (Minimum):-Video:- H.265 or better, H.264H, H.264, Audio:- G.711U/A, G.711Mu, G.726,AAC, G.7234) Wide Dynamic Range:- WDR (120db or more)5) Digital Noise Reduction:- DNR (3D) On/Off6) Video Streaming & Frame Rates :- Triple streaming , configurable (Main stream: 2MP (1920 ×1080)@25/30 fps,Sub streams minimum: 720P@25/30 fps).7) Image Setting: Rotate Mode, saturation, brightness, contrast, sharpness adjustable through client software or web browser, Edge Analytics: Tripwire, Intrusion,Motion Detection8) Cyber Security: AES 256-bit Encryption, Configuration encryption, trusted execution, Digest, security logs, account lockout, syslog, video encryption, IP/MAC filtering, HTTPS, trusted upgrade, trusted boot.9) Onboard Storage: Camera should support built-in Micro SD/SDHC/SDXC Card slot upto 512 GB. It should be supplied with minimum 128GB memoryn Card. 18) Housing/ Enclosure:- IP67 weather proof, IK10, Metallic body.10) Recording Management: Format SD, overwrite, storage management, video to NAS device11) Alarm Trigger : Motion/tampering detection; audio detection; network disconnection detection; IP conflict detection; memory card state detection; memoryspace detection12)Network Protocol: SFTP, IPv6, IPv4, DNS,RTCP, NTP, RTP, HTTP, HTTPS, SNMP TCP/IP, PPPoE, NFS, UDP, ICMP, SSL, DHCP, SMTP, RTSPS,unicast13) System Capability: ONVIF, Camera shall support open source VMS14) Ethernet: 1 RJ 45 10/100 Ethernet port15) Audio : It should support 1 x Built-In Mic and 1/1 Alarm In/ Out for External Mic. and Speakers as per site requirement.16) Power Input: The camera should support simultaneous dual power input—12 VDC (via power adapter) and PoE (802.3af)—to ensure continuous operation in the event of a failure in one power source.17) Power Requirement: 12VDC/24 VAC/PoE (802.3af)/ePoE19) Operating Condition:- Ambient Temperature:- (-)05°C to 50°C, humidity 95% (max) (non-condensing)20) IR life: 40000 hours or higher21) Video Bit rate: 32 KBPS - 8 MBPS or better22) Standards: BIS with ER, STQC Certified, CE, FCC and RoHS |
| 391 | Supplying Installation Testing and Commissioning of 5/6MP IP IR Dome/Bullet Camera having following specifications and features etc :-1)Type of Camera: Dome Camera2) Image Sensor: 1/2.8\\" or better progressive Scan CMOS get color image even at night condition3) Signal System: PAL/NTSC4) Minimum Illumination: 0.008Lux@ F1.4, AGC ON, 0 lux with IR or better5) Imaging: 1/3s to 1/30000s Shutter Support, Auto Gain Control , White Balance- Auto, Back Light Compensation, Multi zone Privacy Masking, HLC,Digital Watermarking.6) On Screen Display: Camera should display Camera title, Date & Time in live & recorded video both.7) Signal to Noise Ratio: > 50 dB8) Day & Night: True Day & Night High Performance Mechanical IR cut filter with auto switch, IR SourceInbuilt IR LED's with effective distance upto 50 Mtrs integrated IR 30 Mtrs for colour view in night.9) Video Compression (Minimum): H.265 or better, Audio:- G.711U/A, G.711Mu, G.726, AAC, G.72310) Wide Dynamic Range: WDR (120dB or more)11) Digital Noise Reduction: DNR (2D/3D) On/Off12) Streaming: Triple streaming, configurable13) Video Streaming & Frame Rates: Triple streaming , configurable Main stream: 5/6MP @25/30 fps, Sub streams: D1@25/30 fps or better14) Image Setting: Rotate Mode, saturation, brightness, contrast, sharpness adjustable through client software or web browser15) Profile Management: User configuration import, export16) Security: User Authentication, Water Marking17) Onboard Storage: Camera should support built-in Micro SD/SDHC/SDXC Card slot upto 512 GB. It should be supplied with minimum 128GB memory Card.18) Recording Management: Format SD, overwrite, storage management, video to NAS device,19) Edge Analytics : Tripwire, Intrusion, Motion Detection20) Alarm Trigger : Motion/tampering detection; network disconnection detection; IP conflict detection; memory card state detection; memory space detection21) Alarm Support: It should have 1/1 Alarm In/ Out Port22) Audio Support: It should have 1x Built-In Mic and 1/1 Audio In/ Out Port for external Mic. and Speaker (As per site requirement) with G.711U/A/ G.711Mu/ AAC/ G.726 audio compression23) Network Protocol: SFTP, IPv6, IPv4, DNS,RTCP, NTP, RTP, HTTP, HTTPS, SNMP TCP/IP, PPPoE, NFS, UDP, ICMP, SSL, DHCP, SMTP, RTSPS, unicast,24) System Capability: ONVIF25) VMS: Camera shall support open source VMS26) Cyber Security: trusted boot, AES 256-bit Encryption, Configuration encryption, trusted execution, Digest, security logs, , account lockout, video encryption, IP/MAC filtering, HTTPS, trusted upgrade.27) Ethernet: 1 RJ 45 10/100 Ethernet port28) Power Input: The camera should support simultaneous dual power input—12 VDC (via power adapter) and PoE—to ensure continuous operation in the event of a failure in one power source.29) Power Requirement: 12VDC/24VDC/PoE (802.3af)/ePoE 30) Enclosure: IP67 weather proof, IK1031) Operating Condition: Ambient Temperature:- (-) 05°C to 50°C, humidity 95% (max) (non-condensing)32) IR life: 40000 hours or higher33) Video Bit rate: 32 KBPS - 8 MBPS or better34) Standards: BIS with ER, STQC Certified, CE, FCC and RoHS5MP/6MP IP IR 2.8/ 3.6/6/8/12 mm fixed lens (as persite requirement) Dome Camera. |
| 392 | Supplying Installation Testing and Commissioning of PTZ (Pan,Tilt and Zoom) IP IR Camera having following spcifications and features etc :-PTZ (Pan,Tilt and Zoom) IP IR Camera having following spcifications and features etc :-1) IP IR PTZ Camera: Motorized PAN TILT ZOOM with IR2) Image Sensor: 1/2.8\\" or better progressive Scan CMOS3)Signal System: PAL/NTSC4) Minimum Illumination: 0.008 Lux@ F1.6, AGC ON,, 0 lux with IR, or better5) Imaging: 1/1s to 1/30000s, Auto Gain Control , White Balance- Auto, Back Light Compensation, Image Rotation, Multi zone Privacy Masking (Upto 24 Area), HLC, Defog, Region Of Interest and EIS features.6) On Screen Display: Camera should display Camera title, Date & Time in live & recorded video both.7) Signal to Noise Ratio: > 50 dB8) Event Notification: Through Relays, E-Mails or FTP9) Day & Night: True Day & Night High PerformanceMechanical IR cut filter with auto switch, IR SourceInbuilt IR LED's with effective distance. The camera should have IR LED’s and cover distance up to 300 meter or above 10) Auto Tracking: The camera should be equipped with Deep-learning-based auto tracking function using simultaneously all of the panning, tilting and zooming should be available. When a motion is detected in a registered monitoring area, the camera should track the motion (object) and capture it.11) Pre/Post Event Buffering: The camera should support atleast of 5 seconds of pre & post event buffering.12) Presets: 300 Presets13) Video Compression (Minimum): H.265 or better, H.264, Audio:- G.711U/A, G.711Mu, G.726, AAC, G.72314) Wide Dynamic Range: WDR (120dB or more), HLC & BLC15) Digital Noise Reduction: DNR (2D+3D) On/Off16) Image Setting: Rotate Mode, ROI ,EIS, Defog, saturation, brightness, contrast, sharpness adjustable through client software or web browser17) Profile Management: User configuration import, export 18) Cyber Security: Configuration encryption, AES 256-bit Encryption, Digest, account lockout, video encryption, IP/MAC filtering, trusted boot, trustedupgrade, trusted execution19) Onboard Storage: Camera should support built in Micro SD/SDHC/SDXC Card slot upto 512 GB . It should be supplied with minimum 128GB Memory.20) Recording Management: Format SD, overwrite, storage management, video to NAS device, remote archive access via FTP login21) Edge based Video Analytics & Alarm Trigger: Motion/tampering detection; network disconnection detection; IP conflict detection; memory card state detection; memory space detection, Tripwire, Intrusion, Object Abandon/ Missing, SMD, Face Detection22) Network Protocol: SFTP, IPv6, IPv4, DNS,NTP, HTTP, HTTPS, SNMP, TCP/IP, PPPoE, NFS, ICMP, DHCP, SMTP, RTSPS.23) System Capability: ONVIF Profile S, G & T. CCTV Camera OEM should be fulltime member of ONVIF and quoted models should be listed on ONVIF officialwebsite (All the certifications & Credentials should be valid on the date of technical evaluation).24) VMS: Camera shall support open source VMS25) Connectivity: 1x LAN RJ-45 (10/100Base-T)26) Audio Support: Audio Interface : The camera should have 1/1 Audio In/Out to connect External Mic and Speaker Audio Compression : PCM, G.711U/A,G.711MU, G.726, MPEG2-Layer2, G.722.127) Alarm In/Out : Alarm In/out- 7/2 Ch In/Out28) Power Input: The camera should support simultaneous dual power input—DC/ AC (via power adapter) and PoE (802.3af)—to ensure continuousoperation in the event of a failure in one power source.29) Power Requirement: 24 VDC, 2.5 A (± 25%), PoE+ (802.3at)30) Enclosure & Weather Proof Standard: IP67 weather proof and IK10, TVS 8000V lightning proof, surge protection, voltage transient protection31) Operating Condition:- Ambient Temperature:- (- )05°C to 50°C, humidity 95% (max) (non-condensing)32) IR life: 40000 hours or higher33) Video Bit rate: 32 KBPS - 8 MBPS or better |
| 393 | Supplying Installation Testing and Commissioning of following Channel Network Video Recorder (NVR) with camera licenses to record for all channels havingspecifications and features etc as mentioned below :1) Network Video Recorder Embedded/ Installed OS (Linux) along with Camera Licenses for number of channels of NVR to record per NVR and to provide alive view, storage and simultaneously Multi-channel playback of all IP, IR camera or more and must be ONVIF with minimum support of 256Mbps incomingBandwidth2) NVR should support H.265 or better, H.264, MJPEG, MPEG4 support3) Must support 1 channel Input, 1 channel Output, RCA for Two-way Talk4) Intelligent auto power on when power resumes after power outage.5) Storage: It should support minimum 2 SATA Slots with 20TB capacity/ Slot.6) Connectivity Interface : 1 Nos. x 10/100/1000 Mbps Ethernet Ports, 1x RS485, 1x RS2327) Backup Interface : Its should have 2 Nosx USB port (1x USB3.0, 1xUSB2.0)8) Video Output Ports: 1x HDMI and 1 VGA9) Alarm Ports: It should have 4/1 Ch In/ Out ports to connect various type of external sensors and output devices like hooter/ Siren etc.10) Email & SMS Altert options: Option for SMS/ Email Alerts to minimum 5 designated mobile number for power failure, HDD failure, vandalism, tempring,network disconnection and panic11) Web & Mobile Application: Web, Mobile app ( For iPhone, iPad, Android Phone) for alerts and viewing.12) Protocols: HTTP, HTTPS, TCP/IP, IPv4, UDP, NTP, DHCP, DNS, SMTP, UPnP, DDNS, Alarm Server, IP Search, Multicast, Auto Registration, ONVIF (Profile T, Profile S, Profile G), CGI, SDK and OEM Cloud for remote monitoring without any public IP need.13) Standards: CE, FCC, RoHS and BIS Certified14) Power Supply : Should support 12VDC, 4Amp or AC100-240V, 50/60Hz Power supply.15) Operating Condition : Ambient Temperature (-5°C to 50°C), humidity 90% (max) (non-condensing)16) The VMS, NVR application shall support all the features & functionalities of the offered cameras.17) VMS should consist of Base license and Channel Licenses. VMS should be provided with camera Licenses , with no dependency of VMS licenses bybinding with the MAC address of the cameras to achieve the functionality.18) The NVR OEM shall be responsible for providing a mobile application compatible with both Android and iOS devices, enabling remote monitoring and playback of cameras/NVR footage19) The OEM must provide its own DDNS server hosted in India, eliminating the need for a public IP address for remote monitoring over the Internet.20) Must support Resolution: 7680x4320 (8K), 3840*2160, 1920×1080, 1280×1024,1280×720, 1024×76821) Must support recording resolution upto 32MP22) Must support Continuous, Alarm, Motion, Instant, Panic Recording Mode23) When alarm recording is enabled and an event occurs, you can click the alarm icon on monitoring page to view the alert details. The snapshot function issupported on monitoring and playback page24) The Network Video Recorder (NVR) shall be configured to send email whenever a system message is created or an alarm event occurs. The email servershall be a valid SMTP server. Each recipient email address shall be configured to receive any combination of critical, warning, or informational messages or alarm notifications. When an alarm occurs, the email message includes the NVR name, time of alarm and a list of camera that is configured to record upon alarm25) It should support Network Support: HTTP, TCP/IP, SMTP, DHCP, DNS, DDNS, FTP, NTP, UPnP, Multi IP Setting. Convert multiple recording files to oneavi/MP4 file.26) General AI Based Search: Search Pictures by channel, time, event type, target classification (Fall Detection, People Approach Detection, People No. Exception Detection, People Staying Detection, Violence Detection.27) Alarm Notifications based on: Motion detection, video tampering, video loss, scene changing, PIR alarm, Camera external alarm, Face detection, facerecognition, perimeter protection (intrusion and tripwire), ANPR, people counting, stereo analysis, crowd distribution, heat map, Disk Full, Storage Error,IP Conflict and abnormal behavior of fan28) Alarm Notification should be linked with Recording, snapshots, Camera external alarm output, buzzer, logs, presets and email.29) Built-In Artificial Intelligence: NVR should havebuilt-in AI :- - 2 Channel face detection and recognition, - Minimum 4 Channel perimeter protection, - Minimum 8 Channel Smart Motion Detection30) Face Recognition Database Capacity: It should support total Blacklist and Whitelist capacity of Minimum 20,000 Faces or more with Face Detection speed of 12 face images/sec.31) Face & Human Attributes Search: Search Pictures/ Video by Gender, age group, glasses, expressions, face mask, beard, Top color, top type, hat, bag, age,gender and umbrella.32) ANPR Capability: It should support ANPR Camera with License plate, plate color, vehicle body, vehicle model, vehicle logo, calling, seatbelt, vehicle registration location etc vehicle attributes.33) Alarm Notifications based on: Motion detection, video tampering, video loss, scene changing, PIR alarm, Camera external alarm, Face detection, facerecognition, perimeter protection (intrusion and tripwire), ANPR, people counting, stereo analysis, crowd distribution, heat map, Disk Full, Storage Error,IP Conflict and abnormal behavior of fan, cybersecurity exception34) Alarm Notification should be linked with Recording, snapshots, Camera external alarm output, buzzer, logs, presets and email.35) General AI Based Search: Search Pictures by channel, time, event type, target classification (Fall Detection, People Approach Detection, People No.Exception Detection, People Staying Detection, Violence Detection.36) Smart playback function: Should support smart search for the selected area in the video and smart playback to improve the playback efficiency37) VCA (Video Content Analytic): Should support multiple video contented analytics based on camera analytics |
| 394 | 08 Channel Network Video Recorder (NVR) having display split :- Main screen: 1/4/8/9, 2nd screen: 1/4/8/9 |
| 395 | 16 Channel Network Video Recorder (NVR) having display split :- Main screen: 1/4/8/9/16, 2nd screen: 1/4/8/9/16 |
| 396 | Supplying Installation Testing and Commissioning of following Channel Network Video Recorder (NVR) with camera licenses to record for all channels havingspecifications and features etc as mentioned below :1) Network Video Recorder Embedded/ Installed OS (Linux) along with Camera Licenses to record per NVR and to provide a live view, storage and simultaneously Multi-channel playback of all IP camera or more andmust be ONVIF with minimum support of 384 Mbps incoming Bandwidth.2) NVR should support video compressions : H.265 or better, H.264, MJPEG.3) Must support 1 channel RCA Input, 2 channel RCA Output for Two-way Talk with G.711U/A, G.711u, PCM, G726 audio compressions.4) Intelligent auto power on when power resumes after power outage.5) Storage: It should support minimum 8/4 SATA Slots with 20TB capacity/ Slot and RAID support of RAID 0/1/5/6/10.6) Connectivity Interface : 2 Nos. x 10/100/1000 Mbps Ethernet Ports, 1x RS485, 1x RS232, 1x eSATA Port7) Backup Interface : Its should have 4 Nosx USB port (2x USB3.0, 2xUSB2.0)8) Video Output Ports: 2x HDMI and 2 VGA9) Alarm Ports: It should have 16/8 Ch In/ Out ports to connect various type of external sensors and output devices like hooter/ Siren etc.10) Email & SMS Altert options: Option for SMS/ Email Alerts to minimum 5 designated mobile number for power failure, HDD failure, vandalism, tempring,network disconnection and panic11) Web & Mobile Application: Web, Mobile app ( For iPhone, iPad, Android Phone) for alerts and viewing.12) Protocols: HTTP, HTTPS, TCP/IP, IPv4/IPv6, UDP, DHCP, DNS, SMTP, UPnP, IP Filter, PPPoE, FTP, DDNS, Alarm Server, IP Search, Multicast, AutoRegistration, ONVIF (Profile T, Profile S, Profile G), CGI, SDK and OEM Cloud for remote monitoring without any public IP need.13) Standards: CE, FCC, RoHS, BIS Certified14) Power Supply : Should support AC100-240V, 50/60Hz Power supply.15) Operating Condition : -5°C to 50°C, humidity 90% (max) (non-condensing)16) The VMS application shall support all the features & functionalities of the offered cameras.17) VMS should consist Licenses for all channels to record Cameras with General, motion detection, intelligent, alarm and POS recording modes. VMSshould be provided with Camera Licenses , with no dependency of VMS licenses by binding with the MAC address of the cameras to achieve the functionality.18) The NVR OEM shall be responsible for providing a mobile application compatible with both Android and iOS devices, enabling remote monitoring and playback of cameras/NVR footage.19) The OEM must provide its own DDNS server hosted in India, eliminating the need for a public IP address for remote monitoring over the Internet.20) Must support Continuous, Alarm, Motion, Instant, Panic Recording Mode21) It should support Resolution: 32MP; 24MP; 16MP; 12MP; 8MP; 5MP; 4MP; 1080p; 720p; D1; CIF; QCIF22) When alarm recording is enabled and an event occurs, you can click the alarm icon on monitoring page to view the alert details. The snapshot function issupported on monitoring and playback page 23) The Network Video Recorder (NVR) shall be configured to send email whenever a system message is created or an alarm event occurs. The email server shall be a valid SMTP server. Each recipient email address shall be configured to receive any combination of critical, warning, or informational messages or alarm notifications. When an alarm occurs, the email message includes the NVR name, time of alarm and a list of camera that is configured to record upon alarm24) It should have Web and GUI interface.25) Built-In Artificial Intelligence: NVR should have built-in AI :- - 2 Channel face detection and recognition, - Minimum 4 Channel perimeter protection, - Minimum 8 Channel Smart Motion Detection26) Face Recognition Database Capacity: It should support total Blacklist and Whitelist capacity of Minimum 20,000 Faces or more with Face Detectionspeed of 12 face images/sec and facility to add Name, gender, birthday, address, credential type, credential No., countries & regions and state to each face image.27) Face & Human Attributes Search: Search Pictures/ Video by Gender, age group, glasses, expressions, face mask, beard, Top color, top type, hat, bag, age, gender and umbrella.28) ANPR Capability: It should support ANPR Camera with License plate, plate color, vehicle body, vehicle model, vehicle logo, calling, seatbelt, vehicleregistration location etc vehicle attributes.29) Alarm Notifications based on: Motion detection, video tampering, video loss, scene changing, PIR alarm, Camera external alarm, Face detection, facerecognition, perimeter protection (intrusion and tripwire), ANPR, people counting, stereo analysis, crowd distribution, heat map, Disk Full, Storage Error,IP Conflict and abnormal behavior of fan, cybersecurity exception30) Alarm Notification should be linked with Recording, snapshots, Camera external alarm output, buzzer, logs, presets and email. 31) General AI Based Search: Search Pictures by channel, time, event type, target classification (Fall Detection, People Approach Detection, People No. Exception Detection, People Staying Detection, Violence Detection.32) Smart playback function: Should support smart search for the selected area in the video and smart playback to improve the playback efficiency33) VCA (Video Content Analytic): Should support multiple video contented analytics based on camera analytics34) Analytics by NVR: Perimeter protection and face recognation |
| 397 | 32 Channel Network Video Recorder (NVR) having display split :- Main screen: 1/4/8/9/16/25/32(36), 2nd screen: 1/4/8/9/16 |
| 398 | 64 Channel Network Video Recorder (NVR) having display split :- Main screen: 1/4/8/9/16/25/36/64, 2nd screen: 1/4/8/9/16 |
| 399 | Supply Installation Testing & Commissioning of 3 Core Power Cable 1.5 sqmm. Make: Finolex/Polycab/Havells |
| 400 | Supplying, installation, Testing and commissioning of following capacity 24 port Layer 2 indoor Network Switch having features and specifications etc. as mentioned here under: At least 24 X RJ-45 Gigabit Ethernet Ports and additional 2 X 10G Base -T with 4 X SFP Ports with non-blocking architecture by having Switching capacity of min. 168Gbps and packet forwarding rate of 125Mpps or higher, 16K MAC table. Console Port, USB port, Stacking support of min. 8 units per stack. Internal dual AC Power supply, STP, RSTP, MSTP, BPDU Filter, BPDU Restriction, Min. 9K Jumbo Frame, LBD, IGMP Snooping V1/V2/V3, MLD Snopping V1/V2. IGMP /MLD Groups 1K or more, IPv4/IPv6 Loopback Interface, 16 L3 IP Interface, Ipv6 ND, VRRPv3, UDP Helper, ECMP. VLAN: 802.1Ǫ, Port based, Ǫ-in-Ǫ, Multicast VLAN, Protocol VLAN, VLAN Trunking, DHCP Snopping, Server, server Screening. RADIUS , TACACS+ Authentication, ǪoS: 802.1P, 8 queues per port, ǪoS : WRR, Strict+WRR, WRED, 802.1p. ACL: MAC based, IPv4C IPv6, TCP/UDP Port number, time based ACL, TFTP Client, SNMP V1, v2c, v3, SNMP traps, RMON, DHCP server, relay, client, LLDP, LLDP-MED, OAM, Dying Gasp, 802.3ah, sflow, RIP, OSPF v2/v3, policy based route, SSL, SSH. 6 kV surge protection on all Gigabit Ethernet ports and on all GE RJ-45 access ports. Certifications: UL, CE, FCC, RoHS, MTCTE, OEM/Product must be on Trusted Telecom Portal of Department of Telecommunication, Government of India etc. complete as required. 24 port PoE Layer 2 Network Switch with PoE Support of 370W or higher with each copper port supporting 802.3at PoE+ min. |
| 401 | Supply, Installation, Testing and comissioning of 16 port Layer ‑2 unmanagable Switch with Power on Ethernet (PoE) enabled, with 16 nos. 10/100/1000base Tx PoE port with 2 SFP port, 1 no. dual personality Gbe Port for copper/fiber uplink, 20 Gbps switching capacity, 14.88 MPPS Forwarding performance , maximum power consumption 64 watt. Make: Cisco/D-link |
| 402 | Supply, Installation, Testing and comissioning of 24 port Layer ‑2 unmanagable Switch with Power on Ethernet (PoE) enabled, with 24 nos. 10/100/1000base Tx PoE port with 2 SFP port, 1 no. dual personality Gbe Port for copper/fiber uplink, 20 Gbps switching capacity, 14.88 MPPS Forwarding performance , maximum power consumption 64 watt. Make: Cisco/D-link |
| 403 | Supplying, Installation, Testing and Commissioning following capacity Serveillance grade Hard Disk with upto 256MB/s Transfer Rate, 256 MB Cache, 7200 RPM Disk Speed, 3.5 inch form factor, SATA Interface, BSMI, ICES-003/NNB-003, CE, FCC, KC, Maghreb, RCM, UKCA, VCCI, CB-Scheme, TUV, ULCertifications. |
| 404 | 4TB (Terabytes) |
| 405 | 6TB (Terabytes) |
| 406 | 8TB (Terabytes) |
| 407 | 10TB (Terabytes) |
| 408 | Micro SD/SDHC Card 128 GB |
| 409 | Supplying, Installation, Testing and commissioning offollowing CAT6 Patch Cord should have ETL/ULverification program certificate for compliance withANSI/TIA-568.2-D etc. complete as required. |
| 410 | Copper Patch Cords of length 1m (3ft) |
| 411 | Copper Patch Cords of length 3m (10ft) |
| 412 | Supplying, Installation, Testing and commissioning offollowing CAT6A Patch Cord should have ETL/ULverification program certificate for compliance with ANSI/ TIA -568.2-D etc. complete as required. |
| 413 | Copper Patch Cords of length 1m (3ft) |
| 414 | Copper Patch Cords of length 3m (10ft) |
| 415 | Supplying, Installation, Testing and commissioning ofRJ45 Connector for CAT 6/6A Cables. RJ45 modular plug supports 4 twisted pairs, 8 positions, 8 connectors. Housing: PC, UL94V-2, transparent color, Use for 24- 26 AWG stranded wires etc. complete as required. |
| 416 | Supply of following electrical /networking components. |
| 417 | ADSL Modem Router Double Antenna |
| 418 | Supply , Installation, Testing and Comissioning of Managed Layer-2 Intelligent 10/100 Ethernet Switch providing 24 x 10/100/1000 MBPS Giga Ethernet ports / with min 2 SFP Giga Ports (provision for Fiber Giga connectivity) with related LAN Base Software including making connections etc as required.All as per pre approved by Engineer in charge. |
| 419 | Supply, Installation, OTDR Testing & Fusion Splicing of Fiber Multimode Pigtail (50/125 μm) made of glass fiber optic, should be fitted at one end with any one type of single ST/E- 2000/SC/LC/MT-RJ/PC type connector in acc., as per latest ammendments of TIA/EIA 569 Standard Specification as per requirments complete in all respect. All as per pre approved by Engineer in charge. |
| 420 | Supply, Drawing and Testing, of stranded Multi mode (50/125 μm) glass optic fiber cable, as per latest ammendments of TIA/EIA 568/ISO/IEC 11801:2011/ IEC 60794-1-2 E1, E3,E11, F1/ EN 50173-1/ EN 187 000/ IEC 60974-2, 2-20, 2-21/ ITU G.652D, construction of LSZH outer sheath cable, cable should be used for LAN and WAN back bones, . With its LSZH sheathing these cables should be ideal for indoor/outdoor installations in existing MS/PVC /HDPE Conduits/ slotted channels with ferruling at both ends for identification complete in all respect. All as per pre approved by Engineer in charge. |
| 421 | 6 fiber |
| 422 | 12 Fiber |
| 423 | 24 Fiber |
| 424 | Supply, Drawing and Testing, of stranded Single mode (9/125 μm) glass optic fiber cable, as per latest ammendments of TIA/EIA 568/ISO/IEC, construction of LSZH outer sheath cable, cable should be used for LAN and WAN back bones, . With its LSZH sheathing these cables should be ideal for indoor/outdoor installations in existing MS/PVC /HDPE Conduits/ slotted channels with ferruling at both ends for identification complete in all respect.All as per preapproved by Engineer in charge. |
| 425 | 6 fiber |
| 426 | 12 Fiber |
| 427 | 24 Fiber |
| 428 | Supply, Installation, OTDR Testing & Fusion Splicing of Fiber Singlemode Pigtail (9/125 μm (OS1/OS2) made of glass fiber optic, with semi-tight buffer PA/PBT, Ø 0.9 mm, yellow, singlemode G652.D (9/125 μm (OS1, OS2), should have length of min 1.5m, should be fitted at one end with any one type of single ST/E-2000/SC/LC/MT-RJ/PC type connector in acc. with IEC 61754-20, Should be delta IL < 0.2 dB after 500 mating cycles, It should be Zirconia (ceramic) ferrule with a PC polished endface geometry connector qualified in acc. with IEC 61753-1 for category U (uncontrolled environment). and qualified in acc. with IEC 61753-1, Performance acc. to IEC 61753-1 (Table A.12) as per latest ammendments of TIA/EIA 569B.3, Standard Specification as per requirments.All as per pre approved by Engineer in charge. |
| 429 | Supply, installation, Testing and Commissioning of 1000 base-LX/LH single mode/Multi mode fibre to 1000 base-T copper giga bit , Media Convertor complete as required complete in all respect. All as per pre approved by Engineer in charge. |
| 430 | Supply , Installation, Testing and Comissioning of Unmanaged Switch Plug-and-play - easy setup with no configuration or no software needed, following Port fast ethernet - 10/100 MBPS auto-negotiation RJ45 ports, IEEE 802.3x flow control ,supports auto- MDI/MDIX, eliminating the need for crossover cables including making connection etc as required complete in all respect. All as per pre approved by Engineer in charge |
| 431 | 4 Port |
| 432 | 8 Port |
| 433 | 16 Port |
| 434 | 24 Port |
| 435 | Supply , Installation, Testing and Comissioning of 24 Port Patch Panel |
| 436 | Supply , Installation, Testing and Comissioning of Adaptor for charger |
| 437 | Supply , Installation, Testing and Comissioning of RJ 45 Jack |
| 438 | Supply and Installation of unsheilded/360 degree sheilded Information outlets made of high impact plastic body with ABS, FR Grade halogen free material with provision for protection against dust in jack, suitable for Cat 6/6A application complying to latest ammendments, According. to Cat. 6/6A channel, It should support channel as well as components requirements of Cat.6/6A standards at frequencies of up to 250 to 500 Mhz. Cat 6/6A unshielded/shielded Jack should be suitable to terminate 4 pair, 23/24 AWG solid/stranded wire diameters, using 100 Ohm unshielded/shielded balance twisted pair cable, the jack should have tooless/impact termination on reliable copper tin plated Insulation displacement contact, with easy lock mechanism, It supports IEC 60603-7-4 and complied with ANSI/TIA/EIA 568 C.2 standard. jack should be RJ11/RJ12/RJ45 compatible. Should support Ethernet 1.2 Gb/s ATM,Digital video and broadband/baseband analog video, Voice over internet protocal (VOIP) Specifications in existing modular/MS Boxes along with necessory connections as required.All as per pre approved by Engineer in charge. |
| 439 | Supply , Installation, Testing and Comissioning of HDMI Cable 3 Mtrs. |
| 440 | Supply , Installation, Testing and Comissioning of HDMI Cable 10 Mtrs. |
| 441 | Supply , Installation, Testing and Comissioning of HDMI Cable 20 Mtrs. |
| 442 | Supply , Installation, Testing and Comissioning of HDMI Switch/Splitter with 1 input and 2 output |
| 443 | Supply & Installation of IP-20 & IK-08 , UL Listed Wall mounted Double Section Communication enclosure (Rack) made from powder coated (60 to 80 Micron) CRCA sheet, front sturdy sheet steel frame folded from one piece and welded with minimum 5mm toughened glass door,Vertical Mounting Rail 1.6 MM with 'U'Marking , with All round protective channel on the door aperture, lock integrated on front door, top and bottom cover with cable entry provision with gland plates, integrated side walls, 2 pair of 19\\" angles with wall mounting provision on wall. Accessories like: 1 No of 19\\" 1U Horizontal Cable manager, 1 No of 90 cfm 230V AC Fan with 1 mts long cable, mounting hardware , 1 No of 19\\" 1U, mountable socket strips with 5 nos of 5A universal sockets with 2 mts long power chord for supplying power to switches, fans etc along with earth continuity kit, indicator, moulded power supply cable. fixing on wall with Suitable Anchor fastner etc as required.All as per pre approved by Engineer in charge |
| 444 | 2 U Rack |
| 445 | 4 U Rack |
| 446 | 6 U Rack |
| 447 | 9 U Rack |
| 448 | Supplying, installation, testing and commissioning of 1 KVA offline UPS with minimum backup of 20 minutes and having over load, short circuit protection. |
| 449 | Supplying, fixing & commissioning of vertical Storage Water Heater (Geyser) of following capacity along with PVC Pipes etc as required. (5 Star with 8 Bar Pressure) |
| 450 | 5/6 Ltr |
| 451 | 15 Ltr |
| 452 | 25 Ltr |
| 453 | 35 Ltr |
| 454 | 50 Ltr |
| 455 | Supplying, fixing & commissioning of Horizontal Storage Water Heater (Geyser) of following capacity along with PVC Pipes etc as required. (5 Star with 8 Bar Pressure) |
| 456 | 25 Ltr |
| 457 | 35 Ltr |
| 458 | 50 Ltr |
| 459 | Supply of following electrical Heater |
| 460 | Single Rod |
| 461 | Double Rod |
| 462 | Three Rod |
| 463 | Pillar Heater Gopi 1500 watt |
| 464 | Rod for Pillar Heater Gopi |
| 465 | Supply of following electrical appliances. |
| 466 | Electric Fly Catcher |
| 467 | 12 V 43 AH sealed rechargeable battery |
| 468 | Tray for setup Box PVC |
| 469 | Electric Kettle upto 1 Ltr. Capacity. |
| 470 | Electric Kettle above 1 Ltr. Upto 2 Ltr. Capacity. |
| 471 | Induction Heater 1400 watt (Cooking) |
| 472 | Induction Heater 1650 watt (Cooking) |
| 473 | Induction Heater 2000 watt (Cooking) |
| 474 | Induction Heater Hot plate (2000-2200 watt) (Cooking) |
| 475 | Hand Dryer |
| 476 | Microwave oven convention type 28 ltr |
| 477 | Air Purifier 250- 270 m³ per hour (Eureke Forbes/Philips) |
| 478 | Air frier 6 KG Make Philips |
| 479 | Drycell 12V AAA/AA |
| 480 | Fly catcher Racket type |
| 481 | Supplying of extension Card |
| 482 | 5 Amp. |
| 483 | 15 Amp |
| 484 | Supplying of LED TV (Smart TV) UHD 4K |
| 485 | 32\\" (Only HD) |
| 486 | Refilling of fire extinguisher ABC Type (MAP 90) 06 Kg Capacity. |
| 487 | Supplying of Refrigerator double door 315 ltr |
| 488 | Supplying of Refrigerator double door 440 ltr |
| 489 | Supplying of Refrigerator double door 537 ltr |
| 490 | Supplying of Refrigerator double door 185 ltr |
| 491 | Supplying, installation, testing and commissioning of 300 Ltrs double door deep freezer |
| 492 | Supply & Fixing of UPS 6KVA online with 30 minutes backup make microtek |
| 493 | Repair of 5 KVA UPS online by way of Replacing its main circuit board make Microtek |
| 494 | Rent Charges for installation of LED Video Wall P3 of size 8' x 20' at JTGC |
| 495 | Rent Charges for installation of LED Video Wall P3 of size 8' x 12' at JTGC |
| 496 | Rent Charges for installation of Sound System at JTGC |
| 497 | Providing and fixing 8' x 10' LED out door Walls displaying preloaded Audio-visual Clippings via USB Drives, maintaining the same by engaging skilled labour and dismantling the same after completion including two way carriage etc. as required at Complete job on rental basis and any other location as per instuction |
| 498 | Providing and fixing Speaker/Sound Systems for LED Walls maintaining the same by engaging skilled labour and dismantling the same afer completion including two way carriage etc, as required. Complete job on rental basis and any other location as per instuction. |
| 499 | Providing & fixing Laptop as per site displaying preloaded Audio-Visual Clippings received via USB Drives, maintaining the same by engaging skilled labour and dismantling the same after completion including two way carriage etc, as required . Complete job on rental basis and any other location as per instuction . |
| 500 | Providing & fixing Additional Aluminium twin core cable 10 mm sq. For providing the power supply to make functional the LED walls & LED TV's installed in the Jammu. and any other location as per instuction. |
| 501 | Illumination of buildings falling under the juridiction. of Jammu Tawi Golf Course, Sidhra on the eve of Independence Day-2025 and Republic-Day-2026. by engaging skilled labour by way of providing & fixing LED type Superior quality laries of different colours by making properly taped individual power connections, maintaining the illumination during nights and dismantling the same after completion as required. Complete job on rental basis and any other location as per instuction. |
| 502 | Hire charges for 50/55\\" HD LED/Plazma TV complete with mounting arrangement , connections, testing etc. with skilled operator to operate system as and when etc as required. |
| 503 | Supply installation Testing and commissioning of cameras (minimum 04 Nos cameras) required for live telecast of the function on 15 August & 26 January Complete job as per site requirement(on Rental Basis) . |
| 504 | Supplying, installation, testing and commissioning of 150/150 Liters of water Cooler having full stainless steel body, cooling capacity 150 ltr/hour and storage capacity 150 ltr alongwith PVC connecting pipes as required. (ISO Certified) . |
| 505 | Supplying, installation, testing and commissioning of 120/120 Liters of water Cooler having full stainless steel body, cooling capacity 120 ltr/hour and storage capacity 120 ltr alongwith PVC connecting pipes as required. (ISO Certified) . |
| 506 | Supplying, installation, testing and commissioning of 120/60 Liters of water Cooler having full stainless steel body, cooling capacity 60 ltr/hour and storage capacity 120 ltr alongwith PVC connecting pipes as required. (ISO Certified) . |
| 507 | Supplying, installation, testing and commissioning of following type of water purifiers alongwith PVC connecting pipes as required. |
| 508 | (RO + UV + UF mineral control with TDS control ) |
| 509 | UV purifier for water cooler |
| 510 | Supplying, installation, testing and commissioning of 1.5 Ton Inverter type Split AC's (copper) Hot/ Cold (all weather) type of minimum capacity following Specification as detailed below. 1. Should be of inverter type2. Cooling capacity (in Tr): 1.53. BEE Star rating: 34. Maximum local temperature: 52 C5. Rated cooling capacity (BTU/hr.): 19000 or above6. Condensing coil: 100% Copper with grooved copper tubes7. Electrical input, 220 V ± 30/50Hz/Single Phase8. Noise level (indoor unit): = close to 35 dB9. Compressor type: rotary or any other suitable technology10. Refrigerant type: R-3211. Anti-Corrosive Coating for the outdoor unit: Bule Fin/Gold Fin or equivalent12. Compressor Warranty: 10 years13. PCB Warranty: 5 year14. Total System Warranty: 1 year15. Minimum noise level of the indoor unit should be around 28 dB (A)16. Should have air filtering mechanism for removing dust17 Supplier has to include brochure of the quoted modelEach unit must provide cooling & dehumidification, be operatable via remote control, operate at 220-240 V AC supply with latest in vogue features. The job includes Repairs made to wall whereever as required. |
| 511 | Supplying, installation, testing and commissioning of 1.5 Ton Inverter type Split AC's (copper) Cold type of minimum capacity following Specification as detailed below. 1. Should be of inverter type2. Cooling capacity (in Tr): 1.53. BEE Star rating: 34. Maximum local temperature: 52 C5. Rated cooling capacity (BTU/hr.): 19000 or above6. Condensing coil: 100% Copper with grooved copper tubes7. Electrical input, 220 V ± 30/50Hz/Single Phase8. Noise level (indoor unit): = close to 35 dB9. Compressor type: rotary or any other suitable technology10. Refrigerant type: R-3211. Anti-Corrosive Coating for the outdoor unit: Bule Fin/Gold Fin or equivalent12. Compressor Warranty: 10 years13. PCB Warranty: 5 year14. Total System Warranty: 1 year15. Minimum noise level of the indoor unit should be around 28 dB (A)16. Should have air filtering mechanism for removing dust17. Supplier has to include brochure of the quoted modelEach unit must provide cooling & dehumidification, be operatable via remote control, operate at 220-240 V AC supply with latest in vogue features. The job includes Repairs made to wall whereever as required. |
| 512 | Supplying, installation, testing and commissioning of 2.0/2.2 Ton Inverter type Split AC's (copper) Hot/ Cold (all weather) type of minimum capacity following Specification as detailed below. 1. Type:- Split (Indoor Unit & Outdoor Unit)2. Cooling Capacity:- Not less than 6000 watts3. Compressor type :- Twin Rotary type Compressor4. Refrigerant:- Eco-friendly (Green Gas) (R-22/ R-32/ R-290/R-410A/R-600A)5. Remote Control:- Yes6. Swing:- Adjustable7. Air flow adjustment:- Auto8. Energy Efficiencyi) ISEE Rating (Desired):- 03 Star Rating, Inverter typeii) BEE rated Energy Efficiency Ratio (EER):- Not less than 3.89. General features:-i) Filters:- Anti Bacteria/Dust filter etc.ii) Air Direction Control:- Airiii) Auto Restart:- Yesiv) Sleep Mode:- Yesv) Timer:- Yesvi) Sound Level inside (in db):- Not more than 50 db & Sound lel outside (in db):- Not more than 56 dbvii) inverter type split AC:- Yesviii) Power Supply/Consumptiona) Power Supply (Volt/Phase/Hz.):- 230/Single/50b) Power consumption (watts) with 100% loading:-Not more than 2000 wattc) Power consumption (watts) with 50% loading:- Not more than 900 watt d) Running Current (Amps):- Max 8.0 to - 9.0 Ampse) Operating Temperature (room) minimum:- 2 º C to 46 º Cf) Maximum Outside (Ambient) Temperature:- Should be capable of operating at least upto 50 ºC Ambient Temperature10. Compressor Warranty: 10 years11. PCB Warranty: 5 year12. Total System Warranty: 1 yearEach unit must provide cooling & dehumidification, be operatable via remote control, operate at 220-240 V AC supply with latest in vogue features. The job includes Repairs made to wall whereever as required. |
| 513 | Supplying, installation, testing and commissioning of 2.0 Ton Inverter type Split AC's (copper) Cold type of minimum capacity following Specification as detailed below. 1. Type:- Split (Indoor Unit & Outdoor Unit)2. Cooling Capacity:- Not less than 6000 watts3. Compressor type :- Twin Rotary type Compressor4. Refrigerant:- Eco-friendly (Green Gas) (R-22/ R-32/ R-290/R-410A/R-600A)5. Remote Control:- Yes6. Swing:- Adjustable7. Air flow adjustment:- Auto8. Energy Efficiencyi) ISEE Rating (Desired):- 03 Star Rating, Inverter typeii) BEE rated Energy Efficiency Ratio (EER):- Not less than 3.89. General features:-i) Filters:- Anti Bacteria/Dust filter etc.ii) Air Direction Control:- Airiii) Auto Restart:- Yesiv) Sleep Mode:- Yesv) Timer:- Yesvi) Sound Level inside (in db):- Not more than 50 db & Sound lel outside (in db):- Not more than 56 dbvii) inverter type split AC:- Yesviii) Power Supply/Consumptiona) Power Supply (Volt/Phase/Hz.):- 230/Single/50b) Power consumption (watts) with 100% loading:-Not more than 2000 wattc) Power consumption (watts) with 50% loading:- Not more than 900 watt d) Running Current (Amps):- Max 8.0 to - 9.0 Ampse) Operating Temperature (room) minimum:- 2 º C to 46 º Cf) Maximum Outside (Ambient) Temperature:- Should be capable of operating at least upto 50 ºC Ambient Temperature10. Compressor Warranty: 10 years11. PCB Warranty: 5 year12. Total System Warranty: 1 yearEach unit must provide cooling & dehumidification, be operatable via remote control, operate at 220-240 V AC supply with latest in vogue features. The job includes Repairs made to wall whereever as required. |
| 514 | Supplying, Installation, Testing & Commissioning of following capacity automatic voltage stabilzer copper wound wall mounted, single phase with range of 90-240 V along with wall mounting brackets & fitting. The job includes repairing the walls where necessary. Warrantee.:- 2 Years from the date of installation. |
| 515 | 4 KVA |
| 516 | 5 KVA |
| 517 | Supplying, Installation, Testing & Commissioning of following capacity automatic voltage stabilzer copper wound wall mounted, single phase with range of 110-240 V along with wall mounting brackets & fitting. The job includes repairing the walls where necessary. Warrantee.:- 2 Years from the date of installation. |
| 518 | 4 KVA |
| 519 | 5 KVA |
| 520 | Supplying & fixing of M.S Wall/Floor Stand duly powder coated for outdoor unit of Split AC |
| 521 | Supplying & fixing of drain pipe for indoor unit 1\\" |
| 522 | Extra length of copper pipe for outdoor unit and suitable size copper cable of required size for 1.5 Ton AC |
| 523 | Extra length of copper pipe for outdoor unit and suitable size copper cable of required size for 2.0 Ton AC |
| 524 | Supplying, installation, testing and commissioning of 1.5 ton Window inverter type AC's (copper) (3 star) Cold type of minimum capacity following sizes as detailed below. Each unit must provide cooling & dehumidification, be operatable via remote control, operate at 220-240 V AC supply with latest in vogue features. and repairs made to window whereever required. |
| 525 | Supplying, installation, testing and commissioning of 2.0 ton Window inverter type AC's (copper) (3 star) Cold type of minimum capacity following sizes as detailed below. Each unit must provide cooling & dehumidification, be operatable via remote control, operate at 220-240 V AC supply with latest in vogue features. and repairs made to window whereever required. |
| 526 | Supply, erection, testing and commissioning of compressor suitable for 2 Ton split /window type A.C with Gas charging and other required accessories to get A.C workable. |
| 527 | Supply, errection, testing and commissioning of compressor suitable for 1.5/1.0 Ton split/window type A.C with Gas charging and other required accessories to get A.C workable. |
| 528 | Provision of Gas charging of 2.0 Ton split/ window type A.C including valve etc if required. |
| 529 | Provision of Gas charging of 1.5 Ton split/window type A.C including valve etc if required. |
| 530 | Provision of Gas topup of 2.0/ 1.5 Ton split/window type A.C including valve etc if required. |
| 531 | Installation of 1.5/2 Ton window A.c |
| 532 | Installation of 1.5/2 Ton split A.c |
| 533 | Installation of Tower A.cs of all capacities |
| 534 | Servicing of Split AC of All Capacities |
| 535 | Servicing of Window AC of All Capacities |
| 536 | Visiting Charges of Technician for testing of Split/ Window AC |
| 537 | Replacement of defective motor of |
| 538 | 1.5 Ton Split /Window A.C Outdoor |
| 539 | 2.0 Ton Split /Window A.C |
| 540 | 1.5 Ton Split /Window A.C Outdoor (Inverter type) |
| 541 | 2.0 Ton Split /Window A.C (Inverter type) |
| 542 | Replacement of defective capacitor for |
| 543 | 1.5 Ton Split/Window A.C |
| 544 | 2.0 Ton Split/ Window A.C |
| 545 | Replacement of defective capacitor for |
| 546 | 1.5 Ton Split / Window A.C |
| 547 | 2.0 Ton Split /Window A.C |
| 548 | Providing & fixing of Blower drum (Split AC) |
| 549 | 1.5 Ton Split A.C |
| 550 | 1.5 Ton Window A.C |
| 551 | 2.0 Ton Split A.C |
| 552 | 2.0 Ton Window A.C |
| 553 | Supply, erection, testing and commissioning compressor suitable for 150/150 ltrs. Water cooler with gas charging and other required accessories to get water cooler workable. |
| 554 | Supply, erection, testing and commissioning compressor suitable 40/80 ltrs. Water cooler with gas charging and other required accessories to get water cooler workable. |
| 555 | Provision of Gas charging of water cooler 150/150 ltr. |
| 556 | Provision of Gas charging of water cooler 40/80 ltr. |
| 557 | Dismantling of existing Split AC & reinstallation of Split AC with gas top up |
| 558 | Dismantling of existing Split AC of All Capacities |
| 559 | Repair of PCB of Split/Window AC 1.5 Ton (Non inverter type AC) |
| 560 | Repair of PCB of Split/Window AC 2.0 Ton (Non inverter type AC) |
| 561 | Repair of PCB of Split/Window AC 1.5 Ton ( inverter type AC) |
| 562 | Repair of PCB of Split/Window AC 2.0 Ton ( inverter type AC) |
| 563 | Replacement of PCB 1.5 Ton Split /Window AC (Non inverter type AC) |
| 564 | Replacement of PCB 2.0 Ton Split /Window AC (Non inverter type AC) |
| 565 | Replacement of PCB of Split /Window AC ( Inverter type AC) |
| 566 | Supplying and fixing of wall stand for outdoor unit for the split A.C. |
| 567 | Replacement of Water purifier chocked candles. ( RO+UV+UF) |
| 568 | Replacement of Water Purifier Candles of water cooler |
| 569 | Servicing of Water purifier candles. ( RO+UV+UF) |
| 570 | Replacement of Pre filter Water Purifier Candles of water cooler (10 inch) |
| 571 | Installation of Pre filter Water Purifier Candles of water cooler with housing (10 inch) |
| 572 | Servicing of Water Purifier Candles of water cooler |
| 573 | Fabrication & fixing of street lights G.I brackets of required dia of following sizes |
| 574 | 1' x 1' with 04 Nos. fastner bolt & 2 clamps |
| 575 | 1' 6\\" x1' 6\\" with 04 Nos. fastner bolt & 2 clamps |
| 576 | 2' x 2' with 06 Nos. fastner bolt & 3 clamps |
| 577 | Supply & Fixixng of fan sheet |
| 578 | Supply & Fixixng of Round sheet |
| 579 | Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with two numbers GI Suspenders i/c base of suitable size GI angle, GI bolts & nuts, fastner etc as required. |
| 580 | 100 mm width X 50 mm depth X 1.6 mm thickness |
| 581 | 150 mm width X 50 mm depth X 1.6 mm thickness |
| 582 | Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray \\"bends\\" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with two numbers GI Suspenders i/c base of suitable size GI angle, GI bolts & nuts, fastner etc as required. |
| 583 | 100 mm width X 50 mm depth X 1.6 mm thickness |
| 584 | 150 mm width X 50 mm depth X 1.6 mm thickness |
| 585 | Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray \\"Tee\\" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with two numbers GI Suspenders i/c base of suitable size GI angle, GI bolts & nuts, fastner etc as required |
| 586 | 100 mm width X 50 mm depth X 1.6 mm thickness |
| 587 | 150 mm width X 50 mm depth X 1.6 mm thickness |
| 588 | Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray \\"Reducer\\" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with two numbers GI Suspenders i/c base of suitable size GI angle, GI bolts & nuts, fastner etc asrequired. |
| 589 | 100 mm width X 50 mm depth X 1.6 mm thickness |
| 590 | 150 mm width X 50 mm depth X 1.6 mm thickness |
| 591 | Supply installation testing and commissioning of 9W, IP65 bollard with System efficacy of 70 lm/W, with PC Diffuser. LED bollard Light shall be made up of Die cast Aluminium Housing for better heat decapitation, height of bollard should not be more than 500mm. L70 life of 50000 Hrs. P.F.>0.90 with THD<25% ,CCT 6500 K, CRI 70,Surge Protection 2 Kv. Input voltage range of 180V to 270V. Certification:- LM79 & LM80 test report should be from govt approved Inhouse NABL lab/ government of India authorised lab . |
| 592 | Providing cement concrete foundation including excavation for the poles (45 cm x 45 cm x 75 cm) in 1:3:6 mix (1 cement : coarse sand : stone aggregate 25 mm size) duly plastered and finishing in an approved manner with necessary curing. Job includes grouting of 4 Nos. 20mm dia 200 mm long J-type foundation bolts and errection of pre-fabricated street light pole on these bolts and tightening with nuts as required. |
| 593 | Supply/Installation/Testing & Commissioning of heritage architectural ornamental decorative cast iron pole having provision to fix decorative single arm bracket. Installation of same with foundation bolts of suitable size to grout it into specially designed RCC foundation, as shown in the enclosed drawing. The decorative light fixture shall be fixed on the top of the pole. The details of pole, bracket & light are given below: -The Pole: The pole with brackets shall look like as shown in the drawing. It shall have all similar features as shown in the enclosed drawing/picture. The Cast Iron Pole of 3 Mtr (3000mm) length. The pole has ornamental base (Approx. overall dimension-height 1050mm,bottom dia 370mm) shall have a provision of inbuilt junction box for fixing MCB’s or cutouts with detachable window cover. The part above ornamental base design consists of decorative sections of circular shapes & collar in different dimension, is made of cast iron in fine finish. The design of the cast-iron parts is clearly shown in the drawing. Mentioned dimensions are proposed dimensions, which may vary with actual measurements (Tolerance of ±5%)Brackets: The ornamental custom-made straight tubular design combo brackets details of the various portions are given in the drawing, which is of 600mm width, 500mm height & which is made in combination of MS hollow round pipe section of dia 40mm & 32mm aesthetically straight armed with cast iron elements. The designs of cast iron to be welded to the brackets shall be similar to the once shown in the drawing. Mentioned dimensions are proposed dimensions, which may vary with actual measurements (Tolerance of ±5%)Light Fixture: The ornamental aluminum casted decorative hanging type light fittings of total height 450mm having suitable Adopter/connector for fixing on required post; as shown in the enclosed drawing/picture. The fixtures have aluminum casted & spinning parts welded with decorative cast aluminum designs for better look. It shall have designed to illuminate large areas with its wide dispersion without affecting the environment. It shall have extra clear transparent unbreakable polycarbonate doom V-shaped light cover with stainless-steel fastening elements. The fixture having provision to fix complete with required power supply. Mentioned dimensions are proposed dimensions, which may vary with actual measurements (Tolerance of ±5%).Finish: Color specification & finishing process must follow as per the ISI standard. All parts must be clean by SHOT blasting process. Further parts are painted in 4 layer coating(Coating thickness-125 to 150 micron) in which first layer with epoxy primer(to prevent corrosion),second layer with epoxy base colour,than third layer polyurethane (PU) metallic paint (Gold/Green/Copper/Silver) & final layer of polyurethane (PU) lacquer (to prevent ultra violets ray). |
| 594 | Material Specification: All this above parts made of cast iron castings must be of FG-150 grade as per IS 210 (2009) standard, Hardness must be in range between 130 BHN to180 BHN. Cast iron must have Chemical composition of Carbon -3.0% to 4.0% Silicon- 1.0% to 2.0%, magnesium -0.5% to 0.7%,sulpher -0.02% to 0.04% & phosphorous-0.07% to 0.09% this composition is best suitable for product strength & life. Heritage architectural ornamental decorative cast iron pole confirming from CAT-Code VHP-801 & (Shall be approved by Department before Supplying) of Dwarka/Karara Mujasame/Hi-Lite Make. |
| 595 | Single arm bracket to be confirmed from CAT-Code D/VHBR-S-004 & (Shall be approved by Department before Supplying) of Dwarka/Karara Mujasame/Hi-Lite Make as per above specifications/enclosed drawing |
| 596 | Double arm bracket to be confirmed from CAT-Code D/ VHBR-S-004 & (Shall be approved by Department before Supplying) of Dwarka/Karara Mujasame/Hi-Lite Make as per above specifications/enclosed drawing |
| 597 | Decorative 50Watt LED Light (luminaries) to be confirmed from CAT-Code D/VGL-003-D & (Shall be approved by Department before Supplying) of Dwarka/Karara Mujasame/Hi-Lite Make. as per above specification/ enclosed drawing with CMC for period of 3-Years from date of comletion of work. |
| 598 | Supply,Installation of 3 Mtr 80 mm G.I Pole with Foundation in conceret mix of 1:2:4 along with muffler upto a height of 450mm . |
| 599 | Supply installation testing and commissioning of 40W,Pole mounted IP65 Post Top with System efficacy of 100 lm/W.L70 life of 50000 Hrs. P.F.>0.95 with THD<10% ,CCT 5700 K,CRI 70,Surge Protection 4 Kv. Input voltage range of 120V to 300V.Certification:- LM79 & LM80 test report should be from govt approved Inhouse NABL lab/ government of India authorised lab. |
| 600 | Repair/Servicing of Water Mist Fans of make Huawei by the OEM Service Provider |
| 601 | Servicing of Fan by way of removing calcium from the nossles, tank and connecting pipes by way of chemicals. |
| 602 | Replacement of Connecting pipes from tank to fan nossles. |
| 603 | Replacement of Motor pumps |
| 604 | Replacement of Wheels |
| 605 | Replacement of Water Tank |
| 606 | Repair/Maintance of installed Sensor doors :- |
| 607 | Replacement of motors |
| 608 | Replacement of sensor |
| 609 | Replacement of Belt |
| 610 | Balancing of doors |
| 611 | Servicing / Greasing of belt |
| 612 | Repair/ maintance of installed boom barrier :- |
| 613 | Replacement of motors |
| 614 | Supply and Fixing boom |
| 615 | Supply of remote |
| 616 | Servicing boom barrier |
| 617 | Rewinding of motors |
| 618 | Repair of installed Servo Steplizer from OEM by way of :- |
| 619 | Supply, Installation , Testing and commissioning of digital Contral Card with sencing circut and protection (High cut, low cut, time delay, phase failer, overload) as approved by Engineer-Incharge |
| 620 | Supply, Installation , Testing and commissioning of 10 kg operating voltage 220 |
| 621 | Supply, Installation , Testing and commissioning of 20 kg operating voltage 220 |
| 622 | Supply, Installation , Testing and commissioning of 3 kg operating voltage 220 |
| 623 | Supply, Installation , Testing and commissioning of contactor (3 pole ac with coil voltage 230 V) |
| 624 | 400 A |
| 625 | 320 A |
| 626 | 250 A |
| 627 | 200 A |
| 628 | 160 A |
| 629 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. |
| 630 | 63 mm dia (OD-63 mm & ID-51 mm nominal) |
| 631 | 90 mm dia (OD-90 mm & ID-76 mm nominal |
| 632 | 120 mm dia (OD-120 mm & ID-103 mm nominal) |
| 633 | Installation of Windows in the existing PC by way of formatting, followed by installation of all essential software such as MS Office, Adobe Reader, Zoom Meeting, and relevant printer drivers (including necessary connecting wires/cables), along with the supply of a wireless keyboard and mouse, as per the directions of the Engineer-in-Charge. Please Enable Macros to View BoQ information |