Tendering Authority Military Engineer Services
Tender No 8401/E8
Tender ID 2026_MES_770637_1
Tender Brief Tender For Repair / Maintenance Of Lt Ug Cables With Connected Items Under Ge (Af) Jamnagar No 1
City Jamnagar
State Gujarat
Document Fees INR 500 /-
EMD INR 90000.0 /-
Tender Value INR 45 Lakhs /-
Tender Type Tender
Bidding Type Open Tender
Competition Type Indian

Tender Details

Tender For Repair / Maintenance Of Lt Ug Cables With Connected Items Under Ge (Af) Jamnagar No 1-- 1 Excavation In Trenches In Soft/Loose Soil Not Exceeding 1.5 Metre Wide And Not Exceeding 1.5 Metre Deep For Laying/Taking Out Of Cables And Foundation Of Poles Etc. And Getting Out, Complete All As Specified And Directed. 2 Excavation Trenches Not Exceeding 1.5M Wide And Not Exceeding 1.5M Depth For Laying Of Cables And Erectioning Of Poles And Getting Out In Any Hard /Dense Soil All As Specified And Directed. 3 Returning, Filling In Trenches (Soil), Including Spreading, Levelling And Well Ramming In Layers Not Exceeding 25 Cm Thick, Complete All As Specified And Directed. 4 Removal Of Surplus Excavated Soil To A Distance Not Exceeding 50Metre And Depositing Where Directed At A Level Not Exceeding 1.5Metre Above The Starting Point, Complete All As Specified And Directed. 5 Material And Labour, Sand Cushioning With A Layer Of Dry River Sand, 80Mm Thick Before Laying Of Cable And 150Mm Thick (Punned Down To 100Mm Thick) After Laying Of Cables, In Trenches/Ducts, Complete All As Specified And Directed. Note : Punned Down Thickness (Overall 18Cm), Shall Be Considered For Measurement And Payment. 6 Supplying And Laying Un-Reinforced Precast Concrete Cable Cover, Classlv, Type 1, Flat, Size 250 Mm X 150Mm X 40Mm Complete All As Specified And Directed By Engineer In Charge 7 Laying Only Old Un-Reinforced Precast Concrete Cable Cover, Classlv, Type 1, Flat, Size 250 Mm X 150Mm X 40Mm Complete All As Specified And Directed By Engineer In Charge 8 Taking Out / Down Old Existing Lt 1100 Volt Grade Cables Of Size 2X16Sqmm, Aluminium Conductor, Xlpe, Armoured, Removal To Store For Re-Use Or For Credit, Complete All As Specified And Directed Note : Excavation Shall Be Measured And Paid For Separately 9 All As Per Serial Item No. 8 Here-In-Before But 16 Sqmm 4 Core Size 10 All As Per Serial Item No. 8 Here-In-Before But 25 Sqmm 4 Core Size 11 All As Per Serial Item No. 8 Here-In-Before But 35 Sqmm 3.5 Core Size 12 All As Per Serial Item No. 8 Here-In-Before But 50 Sqmm 3.5 Core Size 13 All As Per Serial Item No. 8 Here-In-Before But 70 Sqmm 3.5 Core Size 14 All As Per Serial Item No. 8 Here-In-Before But 95 Sqmm 3.5 Core Size 15 All As Per Serial Item No. 8 Here-In-Before But 120 Sqmm 3.5 Core Size 16 All As Per Serial Item No. 8 Here-In-Before But 150 Sqmm 3.5 Core Size 17 All As Per Serial Item No. 8 Here-In-Before But 185 Sqmm 3.5 Core Size 18 All As Per Serial Item No. 8 Here-In-Before But 240 Sqmm 3.5 Core Size 19 All As Per Serial Item No. 8 Here-In-Before But 300 Sqmm 3.5 Core Size 20 Relaying, Jointing, Testing And Commissioning, Already Taken Out Existing Lt Under Ground Cables Xlpe Insulated, Screened, Pvc Bedded, Galvanized Steel Strip Or Wire Armoured Electric Power Cable (Heavy Duty) With Aluminium Conductor Cross Sectional Area 16 Sqmm 2 Core, 1100 Volts Grade, Laid In Trenches, Along Poles Or Passing Through Pipes Or Laid Under Floor Or Through/On Walls Etc, Complete All As Specified And Directed. 21 All As Per Serial Item No. 20 Here-In-Before But 16 Sqmm 4 Core Size 22 All As Per Serial Item No. 20 Here-In-Before But 25 Sqmm 4 Core Size 23 All As Per Serial Item No.20 Here-In-Before But 35 Sqmm 3.5 Core Size 24 All As Per Serial Item No. 20 Here-In-Before But 50 Sqmm 3.5 Core Size 25 All As Per Serial Item No. 20 Here-In-Before But 70 Sqmm 3.5 Core Size 26 All As Per Serial Item No. 20 Here-In-Before But 95 Sqmm 3.5 Core Size 27 All As Per Serial Item No. 20 Here-In-Before But 120 Sqmm 3.5 Core Size 28 All As Per Serial Item No. 20 Here-In-Before But 150 Sqmm 3.5 Core Size 29 All As Per Serial Item No. 20 Here-In-Before But 185 Sqmm 3.5 Core Size 30 All As Per Serial Item No. 20 Here-In-Before But 240 Sqmm 3.5 Core Size 31 All As Per Serial Item No. 20 Here-In-Before But 300 Sqmm 3.5 Core Size 32 Supply, Laying, Jointing, Testing And Commissioning Of Low Tension (Lt) Xlpe Insulated And Armoured, Heavy Duty, Electric Power Cable, Cross Sectional Area 16 Sqmm 2 Core Aluminum Conductor 1100Volts Grade Under Ground Cable Including Both Side Connection With Cable Lugs Etc, Laid In Trenches, Along Poles Or Passing Through Pipes Or Laid Under Floor Or Through Walls Etc, Complete All As Specified And As Directed. Note: Returning Filling & Removal Of Earth, Sand Cushioning And Bricks For Protection Of Cable Shall Be Measured And Paid Separately. Make : Seewel/Havells/Gloster/Polycab/Finolex 33 All As Per Serial Item No. 32 Here-In-Before But 16 Sqmm 4 Core Size 34 All As Per Serial Item No. 32 Here-In-Before But 25 Sqmm 4 Core Size 35 All As Per Serial Item No. 32 Here-In-Before But 35 Sqmm 3.5 Core Size 36 All As Per Serial Item No. 32 Here-In-Before But 50 Sqmm 3.5 Core Size 37 All As Per Serial Item No. 32 Here-In-Before But 70 Sqmm 3.5 Core Size 38 All As Per Serial Item No. 32 Here-In-Before But 95 Sqmm 3.5 Core Size 39 All As Per Serial Item No. 32 Here-In-Before But 120 Sqmm 3.5 Core Size 40 All As Per Serial Item No. 32 Here-In-Before But 150 Sqmm 3.5 Core Size 41 All As Per Serial Item No. 32 Here-In-Before But 185 Sqmm 3.5 Core Size 42 All As Per Serial Item No. 32 Here-In-Before But 240 Sqmm 3.5 Core Size 43 All As Per Serial Item No. 32 Here-In-Before But 300 Sqmm 3.5 Core Size 44 Supply And Laying / Fixing , Gi Pipe Light Grade 100Mm Dia Bore For Cable Protection Fixed To Pole/Wall Or Laid Under Floor/Roadv /Pavement, Including Flat Iron Clamp, Nut, Bolt, Wahser Etc Of Required Size And Taking Out Old & Removal, Complete All As Specified And Directed.Note: Boring Of Holes Under Road Etc. Shall Be Measured And Paid Separately. 45 All As Per Item No 44 Here - In Before But Gi Pipe 80Mm Complete All As Specified And Directed. 46 All As Per Item No 44 Here - In Before But Gi Pipe 50Mm Complete All As Specified And Directed. 47 Supply Jointing Connecting And Testing, Straight Through Joint, Epoxy Based Complete With Jointing Material And All Standard Accessories Suitable For Xlpe Insulated Armoured Aluminium Conductor Cable, Lt 1100 Volts, Aluminium Conductor Of 2/4 Core, 16 To 25 Sqmm All As Specified And As Directed By Engineer-In-Charge. 48 Supply Jointing Connecting And Testing, Straight Through Joint, Epoxy Based Complete With Jointing Material And All Standard Accessories Suitable For Xlpe Insulated Armoured Aluminium Conductor Cable, Lt 1100 Volts, Aluminium Conductor Of 3.5 Core, 35/50 Sqmm All As Specified And As Directed By Engineer-In-Charge. 49 Supply Jointing Connecting And Testing, Straight Through Joint, Epoxy Based Complete With Jointing Material And All Standard Accessories Suitable For Xlpe Insulated Armoured Aluminium Conductor Cable, Lt 1100 Volts, Aluminium Conductor Of 3.5 Core, 70/95 Sqmm All As Specified And As Directed By Engineer-In-Charge. 50 Supply Jointing Connecting And Testing, Straight Through Joint, Epoxy Based Complete With Jointing Material And All Standard Accessories Suitable For Xlpe Insulated Armoured Aluminium Conductor Cable, Lt 1100 Volts, Aluminium Conductor Of 3.5 Core, 120 To 185 Sqmm All As Specified And As Directed By Engineer-In-Charge. 51 Supply Jointing Connecting And Testing, Straight Through Joint, Epoxy Based Complete With Jointing Material And All Standard Accessories Suitable For Xlpe Insulated Armoured Aluminium Conductor Cable, Lt 1100 Volts, Aluminium Conductor Of 3.5 Core, 240 To 300 Sqmm All As Specified And As Directed By Engineer-In-Charge. Note For Item No 47 To 51:-Excavation,Earthwork, Sand Cushion, Cable Cover Will Be Measured And Paid Separately Under Respective Items Of This Schedule

Key Dates

Publish Date 09-06-2026
Last Date of Bid Submission 30-06-2026
Tender Opening Date 01-07-2026

Contact Information

Company Name Military Engineer Services
Contact Person Lt Col Suraj Sadasivan
Address Military Engineer Service Garrison Engineer (AF) No.1 Air Force Station No 1 Jamnagar 361003

BOQ Items

Name of Work:- REPAIR/ MAINT OF LT UG CABLES WITH CONNECTED ITEMS UNDER GE (AF) JAMNAGAR NO 1
Sl. No. Item Description
1Excavation in trenches in soft/loose soil not exceeding 1.5 metre wide and not exceeding 1.5 metre deep for laying/taking out of cables and foundation of poles etc. and getting out, complete all as specified and directed.
2Excavation trenches not exceeding 1.5m wide and not exceeding 1.5m depth for laying of cables and erectioning of poles and getting out in any Hard /Dense soil all as specified and directed.
3Returning, filling in trenches (soil), including spreading, levelling and well ramming in layers not exceeding 25 cm thick, complete all as specified and directed.
4Removal of surplus excavated soil to a distance not exceeding 50metre and depositing where directed at a level not exceeding 1.5metre above the starting point, complete all as specified and directed.
5Material and labour, sand cushioning with a layer of dry river sand, 80mm thick before laying of cable and 150mm thick (punned down to 100mm thick) after laying of cables, in trenches/ducts, complete all as specified and directed. Note : Punned down thickness (overall 18cm), shall be considered for measurement and payment.
6Supplying and laying un-reinforced precast concrete cable cover, classLV, Type 1, flat, size 250 mm x 150mm x 40mm complete all as specified and directed by Engineer in charge
7Laying only old un-reinforced precast concrete cable cover, classLV, Type 1, flat, size 250 mm x 150mm x 40mm complete all as specified and directed by Engineer in charge
8Taking out / down old existing LT 1100 volt grade cables of size 2x16Sqmm, aluminium conductor, XLPE, armoured, removal to store for re-use or for credit, complete all as specified and directed Note : Excavation shall be measured and paid for separately
9All as per Serial Item No. 8 here-in-before but 16 Sqmm 4 Core size
10All as per Serial Item No. 8 here-in-before but 25 Sqmm 4 Core size
11All as per Serial Item No. 8 here-in-before but 35 Sqmm 3.5 Core size
12All as per Serial Item No. 8 here-in-before but 50 Sqmm 3.5 Core size
13All as per Serial Item No. 8 here-in-before but 70 Sqmm 3.5 Core size
14All as per Serial Item No. 8 here-in-before but 95 Sqmm 3.5 Core size
15All as per Serial Item No. 8 here-in-before but 120 Sqmm 3.5 Core size
16All as per Serial Item No. 8 here-in-before but 150 Sqmm 3.5 Core size
17All as per Serial Item No. 8 here-in-before but 185 Sqmm 3.5 Core size
18All as per Serial Item No. 8 here-in-before but 240 Sqmm 3.5 Core size
19All as per Serial Item No. 8 here-in-before but 300 Sqmm 3.5 Core size
20Relaying, jointing, testing and commissioning, already taken out existing LT under ground cables XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured electric power cable (heavy duty) with aluminium conductor cross sectional area 16 Sqmm 2 core, 1100 volts grade, laid in trenches, along poles or passing through pipes or laid under floor or through/on walls etc, complete all as specified and directed.
21All as per Serial Item No. 20 here-in-before but 16 Sqmm 4 Core size
22All as per Serial Item No. 20 here-in-before but 25 Sqmm 4 Core size
23All as per Serial Item No.20 here-in-before but 35 Sqmm 3.5 Core size
24All as per Serial Item No. 20 here-in-before but 50 Sqmm 3.5 Core size
25All as per Serial Item No. 20 here-in-before but 70 Sqmm 3.5 Core size
26All as per Serial Item No. 20 here-in-before but 95 Sqmm 3.5 Core size
27All as per Serial Item No. 20 here-in-before but 120 Sqmm 3.5 Core size
28All as per Serial Item No. 20 here-in-before but 150 Sqmm 3.5 Core size
29All as per Serial Item No. 20 here-in-before but 185 Sqmm 3.5 Core size
30All as per Serial Item No. 20 here-in-before but 240 Sqmm 3.5 Core size
31All as per Serial Item No. 20 here-in-before but 300 Sqmm 3.5 Core size
32Supply, laying, jointing, testing and commissioning of Low Tension (LT) XLPE insulated and armoured, heavy duty, electric power cable, cross sectional area 16 Sqmm 2 core aluminum conductor 1100volts grade under ground cable including both side connection with cable lugs etc, laid in trenches, along poles or passing through pipes or laid under floor or through walls etc, complete all as specified and as directed. Note: Returning filling & removal of earth, sand cushioning and bricks for protection of cable shall be measured and paid separately. Make : Seewel/Havells/Gloster/Polycab/finolex
33All as per Serial Item No. 32 here-in-before but 16 Sqmm 4 Core size
34All as per Serial Item No. 32 here-in-before but 25 Sqmm 4 Core size
35All as per Serial Item No. 32 here-in-before but 35 Sqmm 3.5 Core size
36All as per Serial Item No. 32 here-in-before but 50 Sqmm 3.5 Core size
37All as per Serial Item No. 32 here-in-before but 70 Sqmm 3.5 Core size
38All as per Serial Item No. 32 here-in-before but 95 Sqmm 3.5 Core size
39All as per Serial Item No. 32 here-in-before but 120 Sqmm 3.5 Core size
40All as per Serial Item No. 32 here-in-before but 150 Sqmm 3.5 Core size
41All as per Serial Item No. 32 here-in-before but 185 Sqmm 3.5 Core size
42All as per Serial Item No. 32 here-in-before but 240 Sqmm 3.5 Core size
43All as per Serial Item No. 32 here-in-before but 300 Sqmm 3.5 Core size
44Supply and laying / fixing , GI pipe light grade 100mm dia bore for cable protection fixed to pole/wall or laid under floor/roadv /pavement, including flat iron clamp, nut, bolt, wahser etc of required size and taking out old & removal, complete all as specified and directed.Note: Boring of holes under road etc. shall be measured and paid separately.
45All as per item No 44 here - in before but GI pipe 80mm complete all as specified and directed.
46All as per item No 44 here - in before but GI pipe 50mm complete all as specified and directed.
47Supply jointing connecting and testing, straight through joint, epoxy based complete with jointing material and all standard accessories suitable for XLPE insulated armoured aluminium conductor cable, LT 1100 Volts, aluminium conductor of 2/4 core, 16 to 25 Sqmm all as specified and as directed by Engineer-In-Charge.
48Supply jointing connecting and testing, straight through joint, epoxy based complete with jointing material and all standard accessories suitable for XLPE insulated armoured aluminium conductor cable, LT 1100 Volts, aluminium conductor of 3.5 core, 35/50 Sqmm all as specified and as directed by Engineer-In-Charge.
49Supply jointing connecting and testing, straight through joint, epoxy based complete with jointing material and all standard accessories suitable for XLPE insulated armoured aluminium conductor cable, LT 1100 Volts, aluminium conductor of 3.5 core, 70/95 Sqmm all as specified and as directed by Engineer-In-Charge.
50Supply jointing connecting and testing, straight through joint, epoxy based complete with jointing material and all standard accessories suitable for XLPE insulated armoured aluminium conductor cable, LT 1100 Volts, aluminium conductor of 3.5 core, 120 to 185 Sqmm all as specified and as directed by Engineer-In-Charge.
51Supply jointing connecting and testing, straight through joint, epoxy based complete with jointing material and all standard accessories suitable for XLPE insulated armoured aluminium conductor cable, LT 1100 Volts, aluminium conductor of 3.5 core, 240 to 300 Sqmm all as specified and as directed by Engineer-In-Charge. Note for item No 47 to 51:-Excavation,Earthwork, sand cushion, cable cover will be measured and paid separately under respective items of this Schedule
52Disconnecting XLPE cable of any size from MCB/MCCB/Busbar chamber / LT cables etc for repair /replacment job and reconnecting cable after replacing worn out /damaged lugs, proper clamping, extended terminal link, repair to panel door replacement of door hinges, painting to disturbed surface complete etc all as specified and directed by Engineer-in-charge
53M & L for PCC hard core cutting of path /road of width not more than 15 cm including PCC 1:2:4 with making good with existing surface after laying of LT XLPE complete all as specified and directed by Engineer in Charge Please Enable Macros to View BoQ information

Other Detail

Information Source https://defproc.gov.in/nicgep/app
Download FileName File Description File Size
Download BOQ_863003.xls Tender Documents 0 KB
Download ee9ef54a-8f44-4d89-b006-2b932bd55f84.html Tender Documents 0 KB
Download PS.pdf Tender Documents 0 KB
Download Tendernotice_1.pdf Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.