Indian Tenders

Tender Notice

TDR 55899548
Tendering Authority National Institute Of Technology
Tender No GEM/2026/B/7642402
Tender ID GEM/2026/B/7642402
Tender Brief Bids Are invited for Variable Refrigerant Volume Variable Refrigerant Flow Air Conditioning Machines
City Papum Pare
State Arunachal Pradesh
Document Fees Refer document
EMD Refer document
Tender Value Refer document
Tender Type Tender
Bidding Type Open Tender
Competition Type Indian

Tender Details

Bids Are invited for Variable Refrigerant Volume Variable Refrigerant Flow Air Conditioning Machines Vrf Or Vrv Air Cooled Outdoor Units Suitable For Cooling Or Heating Having 100 Percent Hermetically Sealed Inverter Type Twin Rotary Or Scroll Compressor Capacity Of Machines 14 Hp To 22 Hp , Following Minimum Capacity 4 Way Vrv Or Vrf Cassette Type Indoor Ceiling Mounted Unit Equipped With Synthetic Washable Media Pre Filter,3 Point 2 Tr , Following Minimum Capacity 4 Way Vrv Or Vrf Cassette Type Indoor Ceiling Mounted Unit Equipped With Synthetic Washable Media Pre Filter,4 Tr , Vaccumiazation And Nitrogen Testing Of Following Nominal Sizes Of Soft Or Hard Drawn Copper Refrigerant Piping For Vrv Or Vrf System, Thickness 1 Point 2 Mm , 9 Point 5 Mm Dia Od Soft Drawn With Tube Thickness 1 Point 2 Mm , 12Point 7 Mm Dia Od Soft Drawn With Tube Thickness 1Point 2 Mm , 15 Point 86 Mm Dia Od Soft Drawn With Tube Thickness 1Point 2 Mm , 19 Mm Dia Od Hard Drawn With Tube Thickness 1 Point 2 Mm , 22 Point 2 Mm Dia Od Hard Drawn With Tube Thickness 1 Point 2 Mm , 25 Point 4 Mm Dia Od Hard Drawn With Tube Thickness 1 Point 2 Mm , 28 Point 58 Mm Dia Od Hard Drawn With Tube Thickness 1 Point 2 Mm , 34 Point 9 Mm Dia Od Hard Drawn With Tube Thickness 1 Point 62 Mm , 41 Point 27 Mm Dia Od Hard Drawn With Tube Thickness 1 Point 62 Mm , S I T C Of Y Joints Kit Refrnet , Drain Piping Rigid Pvc Piping Complete With Fittings Supports As Per Specifications And Insulated With 6Mm Thick Closed Cell Elastometric Nitrile Rubber Insulation 25Mm Dia And , 32 Mm Dia , 40Mm Dia , Control And Transmission Wiring , Testing And Commissioning Of Vrf Or Vrv Systems Including Topping Of R410a Gas As Per Site Requirements , Supply And Installation Of U Or V Protection Of Used Copper Pipe At Outer Site For Odu Connection Site , 6Way Load Bank Double Door Enclosure Confirming To Is 8623 Iec 60439 G Frame Panel Boards , Supplying And Fixing Of Following Sizes Of Medium Class Pvc Conduit Along With Accessories 25Mm , Frlsh Or Hffr Pvc Insulated Copper Conductor Single Core Cable In The Existing Surface Or Recessed Steel Or Pvc Conduit As Required 3 X 1 Point 5 Sq Mm , Suitable Size Gi Box With Modular Plate And Cover In Front On Surface Or In Recess , One Number Xlpe Insulated And Pvc Sheathed Copper Conductor Armoured Power Cable Of 1 Point 1 Kv Grade 4 X 16 Sqmm , 16 A Rating 240 By 415 V 10 Ka C Curve Miniature Circuit Breaker Suitable For Nductive Load Of Following Poles In The Existing Mcb Db Complete With Connections Single Pole , Single Pole And Neutral Sheet Steel Mcb Distribution Board 240 V On Surface By Recess Complete 12 Way Double Door , Supplying And Fixing 25 A Rating Single Pole And Neutral , Following Size Of Perforated Painted With Powder Coating M S Cable Trays 150 Mm Width X 50 Mm Depth X 1Point 6 Mm Thickness , Earthing With G I Earth Pipe 4 Point 5 Metre Long 40 Mm Dia Including Accessories , Providing And Laying Earth Connection From Earth Electrode , Providing And Fixing 6 Swg Dia G I Wire On Surface Or In Recess For Loop Earthing , Amc As Per Section C , Installation Of Cassette Ac 2 Ton 5 Star , Copper Pipe , 4 Core Copper Wire , Drain Pipe With Insulation , Odu Stand , Cable Tray , Hanging Rod , Faster Nut , Wrapping Tape , 3 Core Copper Wire Total Quantity : 7210

Key Dates

Publish Date 09-06-2026
Last Date of Bid Submission 01-07-2026
Tender Opening Date 01-07-2026

Contact Information

Company Name National Institute Of Technology
Address 791113,NIT Arunachal Pradesh, Yupia

BOQ Items

Sl. No. Item TitleItem Description
1VRF or VRV air cooled Outdoor units suitable for cooling or heating having 100 percent hermetically sealed inverter type twin Rotary or Scroll Compressor Capacity of Machines 14 HP to 22 HPAs per Specification
2following minimum capacity 4 way VRV OR VRF Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre filter,3 POINT 2 TRAs per Specification
3following minimum capacity 4 way VRV OR VRF Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre filter,4 TRAs per Specification
4vaccumiazation and Nitrogen testing of following nominal sizes of soft OR hard drawn copper refrigerant piping for VRV or VRF system, thickness 1 point 2 mmAs per Specification
59 point 5 mm dia OD Soft drawn with tube thickness 1 point 2 mmAs per Specification
612point 7 mm dia OD Soft drawn with tube thickness 1point 2 mmAs per Specification
715 point 86 mm dia OD Soft drawn with tube thickness 1point 2 mmAs per Specification
819 mm dia OD Hard drawn with tube thickness 1 point 2 mmAs per Specification
922 point 2 mm dia OD Hard drawn with tube thickness 1 point 2 mmAs per Specification
1025 point 4 mm dia OD Hard drawn with tube thickness 1 point 2 mmAs per Specification
1128 point 58 mm dia OD Hard drawn with tube thickness 1 point 2 mmAs per Specification
1234 point 9 mm dia OD Hard drawn with tube thickness 1 point 62 mmAs per Specification
1341 point 27 mm dia OD Hard drawn with tube thickness 1 point 62 mmAs per Specification
14S I T C of Y joints kit RefrnetAs per Specification
15Drain piping Rigid PVC Piping complete with fittings supports as per specifications and insulated with 6mm thick closed cell elastometric nitrile rubber insulation 25mm dia andAs per Specification
1632 mm diaAs per Specification
1740mm diaAs per Specification
18Control and Transmission wiringAs per Specification
19Testing and Commissioning of VRF or VRV systems including topping of R410A gas as per site requirementsAs per Specification
20Supply and Installation of U or V Protection of used Copper Pipe at Outer Site for ODU Connection SiteAs per Specification
216Way Load bank double door enclosure confirming to IS 8623 IEC 60439 G Frame panel boardsAs per Specification
22Supplying and fixing of following sizes of medium class PVC conduit along with accessories 25MMAs per Specification
23FRLSH or HFFR PVC insulated copper conductor single core cable in the existing surface or recessed steel or PVC conduit as required 3 x 1 Point 5 sq mmAs per Specification
24suitable size GI box with modular plate and cover in front on surface or in recessAs per Specification
25one number XLPE insulated and PVC sheathed copper conductor armoured power cable of 1 point 1 KV grade 4 x 16 sqmmAs per Specification
2616 A rating 240 by 415 V 10 kA C curve miniature circuit breaker suitable for nductive load of following poles in the existing MCB DB complete with connections Single poleAs per Specification
27single pole and neutral sheet steel MCB distribution board 240 V on surface by recess complete 12 way Double doorAs per Specification
28Supplying and fixing 25 A rating Single pole and neutralAs per Specification
29following size of perforated painted with powder coating M S cable trays 150 mm width X 50 mm depth X 1point 6 mm thicknessAs per Specification
30Earthing with G I earth pipe 4 point 5 metre long 40 mm dia including accessoriesAs per Specification
31Providing and laying earth connection from earth electrodeAs per Specification
32Providing and fixing 6 SWG dia G I wire on surface or in recess for loop earthingAs per Specification
33AMC As per Section CAs per Specification
34INSTALLATION OF CASSETTE AC 2 Ton 5 StarAs per Specification
35COPPER PIPEAs per Specification
364 CORE COPPER WIREAs per Specification
37DRAIN PIPE WITH INSULATIONAs per Specification
38ODU STANDAs per Specification
39CABLE TRAYAs per Specification
40HANGING RODAs per Specification
41FASTER NUTAs per Specification
42WRAPPING TAPEAs per Specification
433 CORE COPPER WIREAs per Specification

Other Detail

Information Source https://gem.gov.in/
Download FileName File Description File Size
Download b3c09906-c2da-4b91-9d46-fa74216a9326.pdf Tender Documents 0 KB
Download 9443789_Boq_1.xlsx Tender Documents 0 KB
Download ATC_ac93bc47-cbab-4f88-b4b31781002476094_Kalita.docx Tender Documents 0 KB
Download niq_0001_2026-06-09-16-03-44_d87374dceaa6edaa76a3da293fb3075e.pdf Tender Documents 0 KB
Disclaimer :