| 1 | Surface dressing not exceeding 15 cm deep in soft/loose soil, complete as specified and directed. |
| 2 | Excavation in trenches n exc 1.5 m in depth for foundation etc and getting out in soft/loose soil, complete as specified and directed. |
| 3 | M & L for Plain cement concrete (1:4:8) type D-2 using 40mm graded crushed stone aggregate as in foundation filling and mass concrete, complete all as specified and directed. |
| 4 | Use and waste the form work to sides of concrete fdn, footings, bases of columns, plinth beam etc, vertical or to batter, complete all as specified and directed. |
| 5 | M & L for reinforced cement concrete 1:2:4 type B1 using 20mm graded crushed stone aggregate as in foundation footings, foundation beam,plinth beams and bases of columns basement slabs, and mass concrete, complete all as specified and directed. |
| 6 | Use and waste the form work to sides and soffits of floor or roof beams, beam, lintels, cantilevers etc, fair finished surface, complete all as specified and directed. |
| 7 | M&L for reinforced cement concrete 1:2:4 type B1 using 20mm graded crushed stone aggregate as in Roof beams, cantilevers , bressummers, lintels over 1.5 m span, complete all as specifiedand as directed. |
| 8 | Use and waste the form work to sides of pillars, posts, struts, piers, columns, fair finished surface, complete all as specified directed |
| 9 | M & L for reinforced cement concrete 1:2:4 type B1 using 20mm graded crushed stone aggregate as in columns pillers, piers, posts and struts, complete all as specified and directed. |
| 10 | S & F TMT steel bars 10 mm dia and over, cut to length bent to shape required, including cranking, bending spirally for hooping for columns, hooking end and binding with and including MS wire annealed not less than 0.9 mm dia but in stirups, complete all as specified and directed. |
| 11 | S & F TMT steel bars 8 mm dia and over and upto 10mm dia in stirrups, spacers and binders, complete all as specified and directed.. |
| 12 | Returning, filling in, including spreading levelling, watering and well ramming in layers n exc 25 cm in soft/loose soil, complete all as specified and directed.. |
| 13 | Removing Excavated soils not exceeding 50 M and depositing where directed at a level not exceeding 1.5 M above the starting point, complete all as specified and directed. |
| 14 | M & L brick work with sub class 'B' bricks straight or curved on plan exc 6m mean radius built in CM 1 : 4, complete all as specified and directed. |
| 15 | M& L for Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. of Gde Fe 410-W (Gde- E-250) Qty-A, complete all as specified and directed. |
| 16 | S & F for Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified and directed. |
| 17 | S & f for Pre- painted galvatume aluminum zinc coating GI based plain steel sheet 0.50mm thick of an strength of 550 Mpa as in roof covering/cladding to wall and as in eaves bd etc, fixed with self tapping screws, complete all as specified and directed. |
| 18 | M&L for preparation new steel surfaces of any description, over 10cm in width or girth,not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified and directed. |
| 19 | M & L for 15mm thick rendering on other than fair faces of brick work or concrete surface in cm 1:4 to be finished even and smooth with out uing extra cement, complete all as specified and directed. |
| 20 | M & L for 10mm thick rendering on fair faces of brick work or concrete surface in cm 1:6 to be finished even and smooth with out uing extra cement, complete all as specified and directed. |
| 21 | M&L for preparing newly plastered surfaces of walls and applying two coats of cement base paint over a coat of alkali resistant primer, complete all as specified and directed. |
| 22 | M & L for preparing surface of newly plastered walls and applying two coats of oil bond distemper over 3mm wall care putty on wall, complete all as specified and directed. |
| 23 | M & L for broken stone hardcore of gauge n exc. 63mm, deposited, spread and levelled in layers n exc. 15cm thick, watered and rammed to a true surface, complete all as specified and directed. |
| 24 | M&L for plain cement concrete 1:3:6 type C-2 using 40 mm graded crushed stone aggregate 75mm thick as in Subbase of floors, complete all as specified and directed. |
| 25 | M&L for plain cement concrete type B-1, 1:2:4 using 12.5mm graded crushed stone aggregate, 25mm thick, as in sub base under floor and finished rough surface, complete all as specified and directed. |
| 26 | M & L 75 mm thick, plain cement concrete 1:3:6, type C-2 (using 40mm graded crushed stone aggregate) as in plinth protection / hard standing etc, finishing cement concrete surface even and smooth without using extra cement including making joints with bitumastic filing in proportion of bitumen and sand 1:2, complete as specified and directed. |
| 27 | S & F Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, with riveted, bolted or welded attachment of Gde 410-W (Gde-E-250)Qty-A, complete as specified and directed. |
| 28 | S&F 2nd class hard wood plain, solid chowkats and frames wrought framed rebated on the solid, rounded or chamfered put together with glue, pinned at joints complete, complete all as specified and directed. |
| 29 | S&F 35 mm thick 2nd class hard wood plain framed panelled shutters (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board with commercial face veneers, complete all as specified and directed. |
| 30 | S&F 35 mm thick 2nd class hard wood (kail) glazed and skeleton shutters, open rebated and prepared to receive glass, gauze et (without sash bars), edges of framing plain,, chamfered or rounded, fitted with cut and mitred beads for securing glass etc, size of members of shutters as specified in SSR Part-I section -8 , clause 8.24 (a), complete all as specified and as directed |
| 31 | S&F butt hinges, medium weight cold rolled, mild steel of size 100 mm, complete all as specified and directed |
| 32 | S&F 150 mm long aluminium barrel tower bolts of extruded section and fixed, complete all as specified and directed |
| 33 | S&F 150 mm aluminum alloy handles, fabricated type, anodised, complete all as specified and as directed |
| 34 | M&L for Aluminium alloy, anodised sliding door bolt 200mm long,complete all as specified and as directed |
| 35 | S & F Gypsum Board 10mm thick as in Ceiling ,fixed with screw as per manufactures instructions including GI Frame work for gypsum board made out of GI sheet not less than 20 Gauge thickness in ceiling fixed with screws,frame suspended with 4mm dia GI wire as per manufactures instructions ,complete all as specified and directed. |
| 36 | M & L for Machine cut kota stone slab flooring 20 - 25 mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing and including 15mm thick screed bed in cement mortar 1:4 , complete all as specified and directed. |
| 37 | M & L for providing and laying 80mm thick factory made chamfered edge cement concrete paver block of M-30 grade with approved colour, design and pattern as in footpath, parks, lawns, drive ways or light traffic parking etc,of required strength, thickness and size/ shape, made by table vibratory method using PU mould, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand, complete all as specified and directed. |
| 38 | M & L for plain cement concrete 1 : 2 : 4 Type B1 ( using 20 mm graded crushed stone aggregate) as in providing, cement concrete cills, steps, parapets and railings upto 60cm in height, copings, kneelers, apex stones, bed plates, kerbs, complete all as specified and directed. |
| 39 | M & L for excavation in post holes each n.exc 0.50 Cum and getting out in soft/loose soil and removing surplus soil to a distance n exc 50 M and making good surface, complete all as specified and directed. |
| 40 | M & L for plain cement concrete 1 : 2 : 4 Type B2 ( using 40 mm graded crusged stone aggregsate) as in foundation and mass concrete, complete all as specified and directed. |
| 41 | S & F Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I.S. 1161-1979 grade st.-240, complete all as specified and directed. |
| 42 | Surface excavation n. exc 30 cm deep and averaging 15 cm deep and getting out in soft soil, complete all as specified and directed. |
| 43 | M&L for plain Cement concrete type B- 2, 1:2:4 (using 40mm graded crushed stone aggregate) 100 mm thick, as in floors finishing cement concrete surface even and smooth without using extra cemen, complete all as specified and directed. |
| 44 | S & F 2mm thick film coated polycarbonate roofing sheet corrugated/ Plain sheeting with two corrugations side lap fixed with coach screw and washer in roof, wall etc., complete all as specified and directed. |
| 45 | M&L for cutting of kota stone, PCC sub base, soil upto 1.50 m heigth and fixing PVC (SWR) 150mm bore (dia) 6 kg/Sqcm Soil, Waste and Ventilating Pipe, single socketed, in any length with PVC Joints, with or without Ears, including PCC 1:4:8 sub base & all around the pipe and fixing kota stone after fixing of pipe, complete all as specified and as directed. |
| 46 | M&L for Brick work with subclass B bricks, staright or curved on plan exc 6.00 mtr mean redius, biult in 1:6 cement mortar complete., complete all as specified and directed. |
| 47 | M&L for Preparation of new plastered surfaces of walls and applying two coats of oil bound distemper acrylic/distemper oil emulsion acrylic, white or tinted over a coat of primer of same make, complete all as specified and directed |
| 48 | S&F framed work such as grills ,framed guard bars barred iron doors ;ladders framed balusters railings and similar work conforming to Fe 290 Grade-E-165, complete all as specified and directed. |
| 49 | S&F wire netting of galvanised steel wire 1.40mm dia and size of mesh is 12mm fixed with tinned tacks of wire staples or in MS frame work, complete all as specified and directed. |
| 50 | Rolled sections as in main and cross beams, hip and jack rafters;purlins where connected to common rafters and running rails and guides for sliding doors;fixed with angle cleats or other connecting plates of Gde FE-410-W (Gde-E-250) Qty-A complete as specified and directed. |
| 51 | S&F 300 mm aluminium ally, anodised , sliding door bolt with hasp and staple (bolt type) and fixing clips of sheet , cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast aluminium alloy and fixed ,complete all as specified and directed. |
| 52 | M&L for Making single phasing point wiring system used as copper conductor wire for phase and neutral wiring system the wire made out of PVC insulated FRLS of 1100 volt grade with having multistranded copper conductor wire of size 1.5 Sq.mm (Nominal area) ISI marked drawn through wiring system surface on wall or concealed in wall with the help of heavy duty ISI mark PVC casing capping strip / PVC conduit pipe ISI mark in any lengthy wiring system and along with its all connected fittings accessories including providing of pressed steel terminal sunken boxes or heavy duty PVC box and duly fixed it concealed in wall or surface on wall and alongwith providing of back and face top covered plate frame or electro plated plastic laminated sheet for housing / mounting of any type/size switches sockets, regulators etc and including using /drawing of one run of single wire 1.5 sqmm PVC insulated FRLS wire 1100 volt grade ISI marked with multistranded copper conductor wire used as a continuous earth wire for point wiring complete system and including making the good to all disturbed surfaces of wall/ceiling area of new wiring system and to match to it as per the existing surface of wall/ceiling etc., complete all as specified and directed for the following:- |
| 53 | One light point / fan point wiring system controlled by one way switch, complete all as specified and directed. |
| 54 | One 3/5 pin type 5 Amp socket outlet point fixed on same board and controlled by one switch of one way point wiring system, complete all as specified and directed. |
| 55 | Description all as per serial item No 52 here-in-before, but using PVC insulated FRLS wire 1100 volt grade with multistranded copper conductor wire of size 2.5 Sq. mm (Nominal area) ISI Marked for power socket point on indenpent board point wiring system and also providing of 2.5 sqmm PVC insulated FRLS wire 1100 volt grade ISI Marked with multistranded copper conductor wire used as a continuous earth wire for power point wiring system, complete all as specified and directed. |
| 56 | Supply & fixing of modular type switch 5/6 Amps 220 Volts AC,one module , complete all as specified and directed. |
| 57 | Supply and fixing of modular type socket of 5/6 Amps 220 Volts AC, 3/5 multi pin type with two modular, complete all as specified and directed. |
| 58 | Supply and fixing of modular type switch of 15/16 Amps 220 Volts AC one module , complete all as specified and directed. |
| 59 | Supply and fixing of modular type socket of 15/16 Amps 220 Volts AC 5/6 multi pin type with two modular, complete all as specified and directed. |
| 60 | Supply and fixing ceiling rose three terminals type made out of polycarbonate , isolated body, complete all as specified and directed. |
| 61 | Supply and fixing of LED tube light fitting of 1x 20W/22W 220V AC decorative box type with driver, holder including LED tube light with having energy efficient type use in both warm/white type colour complete including providing of suitable type flate fexible cable for electric connection from ceiling rose to fitting comlplete fitting, complete all as specified and directed. |
| 62 | Supply and fixing of LED street light fitting for buildings of rated capacity 35 Watt 230 volt AC with having LED driver,lamp bracket with impact and corrosion resistant with lense embeded including thermal management in multiple optices complete with IP 65/66 protectiuon suitable for out door type made out of high pressure die cast hosing with heat resistant glass complete including providing of suitable size of dia GI pipe light grade bracket and it to match/setting the new fitting fixture hole attechment system of suitable bracket length upto 1.2 mtr long and make to shape / bend of 120 degree angle including duly fixed alongwith existing pole /bldg wall/ roof with the help of 02 Nos of MS fixing clamp alongwith nut bolt and including providing of suitable type of flate fexible two/three core cable and making electric connection, complete all as specified and directed. |
| 63 | Supply & fixing of ventilating exhaust fan made out of complete sturdy engineering plastic body with having motor ,frame louvers & shutter and blade suitable for of size 250 mm 230 Volts including making of suitable type /size of hole on wall etc compete all as specified and directed. |
| 64 | S & F sheet metal enclosure box duly powder coated & framing work with locking system and having double door fixing arrangment system suitable of rating of size/type of distribution board SPN 4/6 way type 220 volt AC supply system with IP-43 protection system and having mounting chanel with having suitable rating of copper bus bar and suitable size of common neutral and earth link and also making all necessary electrical connection and duly fixed surface on wall or conceled in wall with the help of cutting chases to wall for fixing of DB and making good the disturbed wall surface, complete all as specified and as directed. |
| 65 | Supply and fixing of MCB SPN 40 to 63 Amps with breaking capacity 10KA 'C' Curve series, 220 Volts, 50 Hz AC supply complete and also making suitable size / type of electric wiring coneenection, complete all as specified and directed. |
| 66 | Supply and fixing of MCB SP 06 to 32 Amps with breaking capacity 10KA 'C' Curve series, 220 Volts, 50 Hz AC supply complete and also making suitable size / type of electric wiring coneenection, complete all as specified and directed |
| 67 | Supply, laying and testing of LT cable XLPE insulated screened, PVC bedded galvanized steel strip or wire armoured electric power cable (heavy duty) with aluminium conductor 1100 volt grade cross sectional area of size 10 sqmm 2 core including laid in trenches or fixing on poles or passing through pipes, complete all as specified and directed. Please Enable Macros to View BoQ information |