| 1 | M&L for Surface excavation n.exc. 30 cm deep and averaging 15 deep and getting out in hard dense soil complete all as specified and directed. |
| 2 | M&L for Removing excavated soil n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point etc complete all as directed. |
| 3 | M&L for Excavating in post holes (or similar holes) in hard/dense soil each n exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm etc complete all as specified and directed. |
| 4 | M&L for PCC 1:3:6 type C-2 using 40mm graded stone aggregate as in foundation filling and mass concrete etc complete all as specified and directed. |
| 5 | M&L hard core of gauge n exc 63mm, broken stone boulders deposited spread and levelled in layers n exc 15cm thick, watered and rammed to a true surface broken stone or boulders. |
| 6 | M&L for PCC 1:4:8 type D-2 (using 40mm graded stone aggregate ) as in subase finished to receive floor treatment etc complete all as specified and directed. |
| 7 | M & L 25mm thick Cement concrete type B-0, 1:2:4 (12.5mm graded aggregate) as floor complete all as specified and directed. |
| 8 | S&F Mild Steel of gde Fe 410-W as in plain plates cut to required sizes including forming holes without any attachement etc complete all as specified and directed. |
| 9 | M&L for mild steel work tubular pipes as in stanchions incl special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I.S.1161-1979 grade St.-240 etc complete all as specified and directed. |
| 10 | S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified etc complete all as specified and directed. |
| 11 | S & F Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering including ridges /cladding to wall,fixed with self tapping screws complete all as specified and directed. |
| 12 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed |
| 13 | M&L Non skid ceramic coloured tiles 7 to 8 mm thick (Square/rectangular) area of each tile exceeding 0. 11 sqm but not exceeding 0.18 sqm, in skirting etc. laid over 10mm thick screed bed in cement mortar 1:4 and jointed in neat cement slurry and pointed in white or coloured cement to match etc complete all as specified and directed. |
| 14 | M&L for glazed ceramic coloured tiles of size 450mm x 300mm x 7-8mm thick as in vertical portion such as dado,skirting,riser to steps etc with highlighter border, set & jointed in neat cement slurry and pointed in white or coloured pigment to match the shade of tile over and including rendering 10mm thick in cement mortar (1:4) , complete all as specified and directed. |
| 15 | M&L for Vitrified tiles light shade 9-10mm thick (Square) polished, area of each tiles n.exc 0.36 sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured pigment to match the shade of tile over and incl 15mm thick screed bed in CM 1:6 complete all as specified and directed. |
| 16 | M&L for Vitrified tiles,light shade 9-10mm thick (Square) for skirting,vertical surface polished, size of each tiles of size 600x600mm sqm in vertical surfaces etc set and jointed in neat cement slurry and pointed in white or coloured pigment to match the shade of tile over and incl 10mm thick rendering in CM 1:4 complete all as specified and directed. |
| 17 | M & L for Machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab inclunding rubbing and polishing complete incl screed bed 15mm thick in CM 1:6 complete all as specified and directed. |
| 18 | Demolition of cement concrete in ground floors and paving not exceeding 15 cm thickness ( below or above ground level) and disposing the rubbish to a distance exceeding 50 Mtr but not exceeding 100 Mtr away to low lying areas complete all as specified and directed. |
| 19 | M&L for 75mm thick PCC 1:3:6 type C-1 (using 20mm graded stone aggregate as in plinth protection/path without using extra cement,laid in panels including necessary formwork,inishing even and fair complete all as specified and directed. |
| 20 | M&L Machine pressed coloured chequered tiles of size 300 x 300 x 25 mm thick laid over 15 mm thick screed bed in CM 1:6 bedded and jointed in neat cement slurry incl dismantling / demolition and rubbish off the primises etc complete all as specified and directed. |
| 21 | S&L machine pressed precast concrete interlocking paver block rubber moulded, any shape and size confirming ti IS-15658-2006 of 60mm thickness , M-35 grade complete all as specified and directed. |
| 22 | M&L for 30mm thick sand bedding layer for concrete paver tiles laid to true line, level watered and mechanically compacted etc complete all as specified and directed. |
| 23 | Providing cement concrete Type B0 1:2:4 (12.50mm aggregate) in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs not provided for in Item 04028, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, complete all as specified and directed. |
| 24 | M&L preparation of newly steel surfaces exc 10cm width or girth and applying 2 coats of synthethic enamel paint over a coat of primer etc complete all as specified and directed. |
| 25 | Excavation in trenches n.exc 1.5m wide and not exceeding 1.5 m in depth for foundation etc, or for shafts, wells, cess pits, manholes, pier holes, etc. not exceeding 10 Sqm on plan and not exceeding 1.5 m in depth and getting out in soft / loose soil etc complete all as specified and as directed by Engineer-in-Charge. |
| 26 | Returning, filling including spreading, levelling, watering and well ramming in layers not exceeding 25 cm each in soft / loose soil etc complete all as specified and as directed by Engineer-in-Charge. |
| 27 | Demolition of brickwork, built in cement mortar including all quoins, arches, pillars, etc. complete all as specified and directed. |
| 28 | M&L for brick work with sub class \\"B\\" bricks (old size) straight or curved on plan exc 6 m mean radius, built in CM 1:6 complete all as specified and directed |
| 29 | M&L for brick work with sub class 'B' bricks, straight or curved on plan to any radius in half brick thick wall built in cement morter 1:4 , all as specified and directed. |
| 30 | Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; n. exc 200m thick (Horizontal or sloping) etc complete all as specified and directed. |
| 31 | Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc complete all as specified and directed. |
| 32 | M&L RCC M-25 (Design Mix) Concrete as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves all as specified and as directed. |
| 33 | M&L TMT bars 10mm dia and over, cut to length, bent to shape required, incl cranking, bending spirally for hooping for columns, hooking ends and binding with the including mild steel wire (annealed) not less than 0.9mm dia or securing with clips etc complete all as specified and directed. |
| 34 | All as per ser item no 31.00 above but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders etc complete all as specified and directed. |
| 35 | Taking down cement plaster on brick/stone/concrete walls /ceiling incl racking out joints etc,hacking for key, scrubing down with water etc & dispose off debris upto a distance n exc. 500 mtrs where directed complete all as specified and directed.note -rate applicable upto four storey height incling all scaffolding work |
| 36 | M&L for rendering 12 mm thick on other than fair faces of brick work or concrete surfaces on walls in CM 1:6. finishing even and smooth without using extra cement complete all as specified and directed. |
| 37 | M&L for rendering 10 mm thick on fair faces of brick work or concrete surfaces on ceiling in CM 1:3. finishing even and smooth without using extra cement complete all as specified and directed. |
| 38 | M&L for rendering 15 mm thick on fair faces of brick work or concrete surfaces on walls in CM 1:4. finishing even and fair complete all as specified and directed. Note: (i) WPC shall be measuared seperatly and paid @ 200ML for 50kg cement bags or as per manufacturer's instructions. (ii) Rate applicable upto four storey height incling all scaffolding work. |
| 39 | Supply only liquid water proofing compound. |
| 40 | M&L preparation of new plastered surface of walls and applying two coat of oil bound distemper over 1mm thick wall carwe putty complete all as specified and directed |
| 41 | M&L for applying three coat of white wash on ceiling surfaces incl preparation of newly plastered ceiling surfaces complete all as specified and directed. |
| 42 | M&L for preparation of newly plastered wall surfaces and applying two coats of cement base paint over a coat of alkali resistant primer complete all as specified and directed. |
| 43 | M & L for PCC 1:2:4 Type B-2 (using 40mm graded stone aggregate) as in flooring incl finishing the cement concrete surface even and smooth with using extra cement , rubbish off the primises and incl demolition complete all as specified & directed . |
| 44 | Providing and laying 40mm thick bitumen mastic wearing course (as per specifications) with industrial bitumen of grade 85/25 conforming to IS : 702, prepared by using mastic cooker and laid to required level and slope, including providing antiskid surface with bitumen precoated fine grained hard stone chipping of approved size at the rate of 0.005 cum per 10 sqm and at approximate spacing of 10 cm centre to centre in both directions, pressed into surface protruding 1 mm to 4 mm over mastic surface, including cleaning the surface, removal of debris etc. all complete. (Considering bitumen using 10.2% as per MORTH specification). |
| 45 | Dismantling brick tiles or terracing single layer as in roofing complete all as specified and directed. |
| 46 | Demolition of mud in roofs, any thickness, including plastering and leeping (whether full thickness removed or only a part thereof) complete all as specified and directed. |
| 47 | M & L for 50mm avarage thickness PCC 1:2:4 type B1 (using 20 mm graded stone aggregate as roof padding sub base floor complete all as specified and directed. |
| 48 | M&L for preparation of roof surface & applying evenly a tack coat of industrial bitumen primer 85/25 grade @ 1.2 Kg/Sqm including APP based polymeric membrane minimum weighing 3 kg/sqm and minimum 3 mm thick reinforced wih polyster non wove fabric (wt not less than 150 gms/sqm) land on primed surface by forced application, joints to be touched hot and width of overlaps not be less than 150 mm complete all as specified and directed. |
| 49 | M&L, 40 mm thick brick tiles laid and joints in cement mortar (1:6) over 15mm thick and jointed grouted flush pointing in cement Motar (1:3) completed all as specified and directed. |
| 50 | All as per ser item No 47.00 above but except bricks tiles complete all as specified and directed. |
| 51 | Taking down Chowkats or frames from the opening of size not exceeding 1.5 sqm each with shutters ( without taking off shutters from the frames) complete all as specified and directed |
| 52 | Taking down Chowkats or frames from the opening of size exceeding 1.5 but n exc 4 sqm sqm each with shutters ( without taking off shutters from the frames) complete all as specified and directed |
| 53 | S&F 30 mm thick Factory Made Solid Panel PVC Door Shutter consisting of frame made out of M.S. tubes of 19mm x 19mm for stiles, & 15mm x 15mm for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC sheet 5mm thick ‘C’ channel having a 5mm thick PVC sheet strip of 20mm width stuck inside with solvent cement, forming stiles, and plain colour PVC sheets for top rail, lock rail & bottom rail on either side, and as gap insert for top rail & bottom rail. Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with PVC sheet beading, and joined together with solvent cement adhesive etc. complete as per direction of Engineer-in-charge, manufacturer’s instructions and drawing. The width of stiles & rails will be in proportion to the width of the door shutter as per SSR Clause No 8B.2.1 etc complete all as specified and directed. |
| 54 | S&F Solid PVC Door frame of sizes 95mm x 50 mm made out of 5 mm laminted both side colour PVC sheet reinforcement with MS square tube,supplying & fixing in opening as per specification & drawing complete all as specified and directed |
| 55 | S&F 25mm dia, 1mm wall thickness stainless steel, fancy type,decorative curtain rod with decorative ball type brackets, including taking down old any type curtain rod complete all as specified and directed. |
| 56 | M&L for supplying & fixing in opening as per specification & drawing etc complete all as directed. |
| 57 | S & F 2nd class H.W. glazed & skeleton shutter 35mm thick factory made open rebated & prepared to receive glass gauze etc (without sash bars) edges of framing plain, chamfered or rounded, fitted with cut and mitered beads for securing glass, gauge etc size of members complete all as specified and directed. |
| 58 | S & F 2nd class HW shutters 35mm thick, plain framed paneled shutter factory made (two panel) with lock rail & panel of 9mm BWP commercial ply or 12mm veneered particle board with commercial veneering on both faces. The size of rail and style as per IS:1003 complete all as specified and directed. |
| 59 | S&F powder coated aluminium frame for doors, windows, ventilators with one or more rebates including joining cleats for fixing complete all as specified and directed by Engineer-In-Charge. (Min. thickness of powder coating 50 micron) |
| 60 | S&F aluminium powder coated shutter (for window and ventilator) side hung type without sash, aluminium section wighing 0.55 kg/m including necessary jointing cleats,glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fitting such as peg stays 150mm long (1 no.) hinges type B-21 100mm long( 2 no) suitable handle (1 no) complete all as specified and directed. |
| 61 | S&F GI wire cloth, 0.56 mm nominal dia. of wire and average width of aperture 1.18 mm and fixed with tinned tacks, or galvanised wire staples complete all as specified and directed |
| 62 | S&F Sheet glass, 3mm thick ordinary quality, in squares, not exceeding 0.50 sqm in each pane including wooden beading fixed nails or fix with oil putty complete all as specified and directed. Note: Upto four storey height including all scaffolding work |
| 63 | All as per Srl item No 58.00 above but figured glass pin head type & glazing with oil putty Note upto four storey height including all scaffolding work complete all as specified and directed |
| 64 | S&F 300mm long Aluminium alloy Anodised, sliding door bolt with hasp, staple ( bolt type) and fixing clips of sheet , cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed complete all as specified and directed |
| 65 | S&F 150 mm Aluminium, anodised, barrel tower bolts of extruded section and fixed complete all as specified and directed |
| 66 | S&F 150 mm Extruded aluminium alloy handles, fabricated type, anodised complete all as specified and directed |
| 67 | S&F 100mm long butt Hinges, medium weight, stainless steel and fixed complete all as specified and directed. |
| 68 | M & L for 15 to 18mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite. including Screed bed or bedding layer of mortar 20 mm thick for laying floor finishes complete all as specified and directed |
| 69 | S&F vitreous china squatting pan ( Orissa Pattern) size 580 x 440 mm (white), with PVC (SWR) P trap, integral foot rest including water connection to trap and flushing pipe, flushing cistern etc complete and bedding in PCC 1:7:12 type F-2 including taking down/dismantling old unserviceable WC complete all as specified. Note :- Flush pipe and flushing cistern to be measured and paid separately. |
| 70 | S&F in repairs vitreous china wash down water closet pan pedestal pattern white including fixing bolts and seat cover white for pedestal pan with flat bottom and cover and mild steel chromium plated hinging device (excluding flushing cistern and flush pipe). |
| 71 | S&F vitreous China couter top oval shaped wash basin of size 560mmx 410 mm including CP waste coupling 32mm bore and waste pipe, complete all as specified. |
| 72 | Supply and fixing in repair PVC waste pipe 32/38/40mm dia, 600 to 750mm long complete all as specified. |
| 73 | Supply & Fixing vitreous china urinal half stall type with CP spreader white with grating and union for discharge pipe, including providing and fixing plug, bedding urinal against wall in cement mortar 1:2 securing urinal to plugs with and including 60 mm long brass screws, pointing around urinal back in cement fixing with brackets, & waste pipe etc complete all as specified and directed |
| 74 | S&F 10 Ltr capacity PVC valveless symphonic action type flushing cistern white low level with ball valve flote handle including bracket and flush pipe of polythylene of low or high density or PVC,32mm dia complete all as specified and directed. Note: Flush tank can be conceiled in wall if reqd i.e in the case of wall hung type water closet pan complete all as specified and directed |
| 75 | S&F rotational moulded polythene, triple layers, water storage tank other than black colour 1000 Ltr capacity, closed top, cylindrical, hoisted and fixed in position including including 20mm bore PTMT ball valve epoxy coated minium weight 210gms with aluminium rod and dismantling water tanks Exc 500 Ltr & not exceeding 100Ltr complete all as specified and directed |
| 76 | S&F 15mm dia GI tubes medium grade with all fitting and fixed complete to walls and ceiling or laid in floorsincl taking down all as specified and directed. |
| 77 | S&F 20mm dia GI tubes medium grade with all fitting and fixed complete to walls and ceiling or laid in floors all as incl taking down specified and directed. |
| 78 | S&F in 20mm repars stop valve cast copper alloy screwed down high pressure with crutch or butterfly handle, screwed both ends for iron pipe complete all as specified and directed |
| 79 | S/F 15mm bore angle cock cast copper alloy CP screwed down high pressure with crutch or butterfly handle complete all as specified and directed. |
| 80 | S&F of brass cromium plated fancy type bib taps 15 mm bore long nose screwed down screwed for iron pipe or for brass complete all as specified and directed |
| 81 | S& F fo swan neck pillar cock brass chromium plated fancy type for mixing of cold & hot water screw for 15mm bore iron pipe complete all as specified and directed. |
| 82 | S&F 125mm brass CP shower rose fancy type with CP arm complete all as specified and directed. |
| 83 | Supply and fix sheet glass shelf assembly consisting of 5.50mm thick sheet glass shelf 12cm wide with cromium plated bracket guard and and railing 60cm long including taking down old broken glass shelf, if available, complete all as specified and directed. |
| 84 | Supply and fixing Health faucet (ABS body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metr long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect complete all as specified. |
| 85 | Supply and fix CP flushing jet including 15mm bore 450mm long PVC pipe connection for Europian type closet of suitable length with brass check nut complete all specified and directed |
| 86 | S&F, glass corner minimum size 300mmx300mm minimum 5.50mm thick with cromium plated bracket guard and and railing including taking down old broken glass, complete all as specified and directed. |
| 87 | Supply and fix stainless steel soap dish of min size 130mmx 80mm including taking any old pvc/steel tray if available complete all as specified and directed. |
| 88 | Supply and fix in repairs toilet paper holder with flat recessed type stainless steel complete all as specified and directed |
| 89 | S&F PVC connection 15mm size with PTMT nuts of length 450mm complete all as specified and directed |
| 90 | S&F 600mmx450mm bevelled edge mirror of selected quality glass,mounted on 6mm thick commercial plywood and fixed to wooden plug with chromiuum matched brass screws complete all as specified and directed |
| 91 | S and F brass chromium plated tubular towel rail D type 60cm long between flanges including bracket complete all as specified and directed |
| 92 | Taking down eaves gutters and rain water pipes ( any size or pattern) , including all fittings , heads, shoes, bends, swan necks, etc measured overall as fixed along the centre line over fittings and accessories complete all as specified and directed |
| 93 | S&F 110mm bore PVC(SWR) pipes single socketed in any length fixed to walls including all fittings complete all as specified and directed by Engineer-in-charge |
| 94 | S&F 75mm bore PVC(SWR) pipes single socketed in any length fixed to walls / laid in floor including all fittings complete all as specified and directed by Engineer-in-charge |
| 95 | S&F 110mm bore PVC (SWR) bends any radius Withiout access door complete all as specified and directed |
| 96 | S&F 75mm bore PVC (SWR) bends any radius Without access door complete all as specified and directed |
| 97 | S&F 110mm bore PVC (SWR) junction single/double, (single/double T), equal or unequal with access door complete all as specified and directed |
| 98 | S&F PVC(SWR) vent cowl 110mm dia complete all as specified and directed |
| 99 | S&F stack clamp out of 50mmx5mm flat iron and 16mm dia round iron stay including bolts and nuts and securing end of stay to wall or roof 100mm complete all as specified and directed |
| 100 | M&L 75mm bore PVC (SWR) floor trap, plain with CP grating including jointing with solvent cement complete all as specified and directed |
| 101 | M & L for 450 mm bore Reinforced concrete pipes, class NP2, laid and jointed complete with collars, 450mm dia complete all as specified and directed |
| 102 | S&F aluminium wire guard mesh of 4mm nominal dia of wire and average width of aperture 75 - 85mm and fixed with aluminium frame / staples complete all as specified and directed |
| 103 | S&F Sheet glass, 5.5mm thick ordinary quality, in squares,exceeding 0.50 sqm in each pane including rubber packing and aluminium beading with and incl solar control film 25 Micron reflective type sticked to glass panes as per instructions of manufacturer scomplete all as specified and directed |
| 104 | Taking down aluminium/copper point wiring from existing conduit / batten (light, fan, socket or power) complete such as switches, ceiling rose, pendent, regulators, socket, light fittings etc and removing material from site and making good the disturbed surface of wall / floor etc, complete all as specified and directed. |
| 105 | S&F door closer hydraulically regulated, (Alminiumextruded section body) designation No. 3, universal type, suitable for door shutters of 851 to 1000mm in width and of weight between 61 to 80 Kg and fixed complete all as specified and directed |
| 106 | Material and labour for providing and fixing gypsum board 12.mm thick on ceiling fixed with screws as per manufacturer instructions incl (i) Gl frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre (ii).Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I.flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified |
| 107 | S&F PVC wall panelling hollow multichambered section average thickness 7-8mm fixed inclusive of moulding and end caps fixed with PVC sleeves and screws as required at site complete all as specified and directed.Note:- Colour/Shade will be decided by GE Please Enable Macros to View BoQ information |
| 108 | S&F PVC wall panelling hollow multichambered section average thickness 7-8mm fixed inclusive of moulding and end caps fixed with PVC sleeves and screws as required at site complete all as specified and directed.Note:- Colour/Shade will be decided by GE Please Enable Macros to View BoQ information |