| 1 | Dismantling posts or struts of old/unserviceable/broken of any type (wood, steel or RCC) any section including taking out embeded portion and making good disturbed ground all as specified |
| 2 | M & L for surface dressing nexc 15 cm deep, site clearance, to remove the bushes and making area workable. |
| 3 | Excavation in post holes each not exceeding 0.5 Cum, getting out returning filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm watering and removing surplus soil to a distance not exceeding 50 M and making good surface all as specified. |
| 4 | M&L PCC (1:4:8) type D-2 (using 40mm graded aggregate) as in foundation filling and mass concrete etc all as specified & directed. |
| 5 | M &L for posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified & directed by Engr-in-Charge. |
| 6 | M&L for providing reinforced cement concrete type B-1, 1:2:4 (20mm graded aggregate) in precast post, fencing post, straing or terminal post, struts etc for fencing, average sectional area exc 100 and nexc 250 sq.cm, with or without chamfered angles and flat, splayed, rounded or mitred tops etc complete all as specified & directed by Engr-in-Charge. |
| 7 | M & L for formwork to edges of concrete, opening in cocnrete walls, floors and roofs and side of RCC/PCC bands in walls and simillar work all exceeding 20 cm wide complete all as specified & directed by Engr-in-Charge. |
| 8 | M&L for TMT bars 10 mm dia and over , cut to length, bent to shape required, including cranking, bending spirally for hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing clips complete all as specified & directed by Engr-in-Charge. |
| 9 | M&L for TMT bars 6 to 8mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing clips but in stirrups complete all as specified & directed by Engr-in-Charge. |
| 10 | Dismantling fencing wire mesh any type complete all as specified and directed by Engr-in-Charge. |
| 11 | Supply only Chain link fencing incl line wires, any mesh, size and type to any standarards, rails straining bolts etc incl provn of binding wire.complete all as specefied and as directed. |
| 12 | Fixing only chain link fencing including fixing of line wires, any mesh, size and type to any type of staindard rails, straining bolts, etc. including provision of binding wire complete all as specified and as directed |
| 13 | S&F Mild steel round bars 10mm dia and over as in strengthening bars for bending cranking spirallt for hooking for chain link, hooking end and welding with flats of chain link fencing Fe 410W (Gde E-250 ) quality -A or FE-290 (Gde E-165) complete all as specified and directed by Engr-in-Charge. |
| 14 | S & F Galvanised 2 strand, steel barbed wire 2.24 mm dia barbed with with 2 mm dia barbs at 75 mm at spacing and straining and fixing to any type of standard rails straining bolts including securing or tying at crossings with land provision of galvanised mild steel pins etc as directed by Engr-in-Charge. |
| 15 | S & F framed work such as grills, gratings, door etc with ends of bars shouldered and/riveted or forged into spikes; framed guard bars; barren iron doors; ladders; framed balusters,walk ways; railings and similar work incl cattle trap confirming to Fe.290.Gde-E-165. |
| 16 | M&L for two coats of synthetic enamel paint over a coat of Red oxide, Primer including preparation of surface over 10 cm width and girth etc complete all as specified and directed by Engr-in-Charge. |
| 17 | Demolition of brick work/ stone boulder built in cement mortar or cement lime mortar and complete all as specified and directed by Engr-in-Charge. |
| 18 | M&L PCC type B1 1:2:4 (using 20mm graded curshed stone aggregate ) in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, benching, kneelers, apex stones, bed plates, kerbs not provided for in Item 04028, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed |
| 19 | M&L for providing Pre cast cement concrete jalli 35 mm thick, in repairs type BO using 12.5 mm gradedaggregate, set in CM 1:4 complete all as specified and directed by Engr-in-Charge. |
| 20 | M & L Brickwork with fly ash bricks, straight or curved on plan exc 6m mean radius, built in cm (1:6), rise of hight for brick wall complete all as specified and as directed. |
| 21 | M& L, Brickwork, with subclass 'B' bricks in half brick thick honey comb work, built in CM 1:4. |
| 22 | Brickwork with fly ash bricks, straight or curved on plan exc 6m mean radius, built in cm (1:6), rise of hight for brick wall but except Bricks including stacking the serviceable brick for re-use, cleaning of brick , all extra handling and disposal of debris and rubbish to low level area/500 mtr from site complete all as directed by the Engr-in-Charge. |
| 23 | M&L walling of random rubble masonry uncoursed, well bonded, bedded and solidly hearted built in CM (1:6) all as specified |
| 24 | .-Ditto- but item No. 23 above but except stones complete all as specified and directed by Engr-in-Charge. |
| 25 | M& L for 15mm thick rendering in CM 1:6 on fair faces of brick work or concrete surfaces, surface finished smooth and even without using extra cement etc complete all as specified and as directed. |
| 26 | M&L for preparation of New surfaces and applying two coats of cement base paint with roller with primer on New Surface complete all as specified and directed |
| 27 | Dismantling of floor hearth wall tiling including cement mortar beddind but not backing removing serviceable material to store all as specified and directed. |
| 28 | 20mm thick Granite (of any type) tiles machine cut, in skirting/ dado laid over cement screed and jointed with grey cement slurry, and pointed with white cement with admixture of pigment to match the shade ofgranite stone including grinding and polishing cement to match over 10 mm thick rendering in CM 1:4 complete all as specified and directed |
| 29 | M&L for coloured ceramic glazed tile (Premium quality), 7 to 8mm thick (square / rectangular) on vertical surfaces in Cement slurry and pointed in coloured cement to match over 10 mm thick rendering in CM 1:4 complete all as specified and directed |
| 30 | Demolition of cement concrete in ground floors and paving nexc 15cm thick above or below ground level all as specified. |
| 31 | M&L for 75mm thick cement concrete type C-2, 1:3:6 (40mm graded aggregate) as in plinth protection finished even and smooth without using extra cement complete all as specified |
| 32 | M&L 25 mm thick PCC 1:4:8 type D2 using 12.5mm graded stone agg as in filling Sub base/flooring complete all as specified and directed. |
| 33 | M &L chequered tiles (Cement) 20cm X 20cm x 25mm thick, set and jointed and pointed in neat cement slurry in floor with grey cement and pigment over & including 15mm thick screed bed in CM (1:6) Complete all as specified and directed. |
| 34 | M&L 60 mm thick machine pressed precast concrete interlocking paver block any shape & size confirming to IS 15658-2006 of 60mm thickness, M-35 grade with grey/White cement & no pigment including PCC 1:2:4, B0 using 12.5mm graded stone aggregate in all edges of interlocking complete all as specified and directed by the Engr-in-Charge. |
| 35 | M&L Coloured rubber moulded in any format 60 mm thick machine pressed precast concrete interlocking paver block any shape & size confirming to IS 15658-2006 of 60mm thickness, M-35 grade with grey/white cement & pigment including PCC 1:2:4, B0 using 12.5mm graded stone aggregate in all edges of interlocking complete all as specified and directed by the Engr-in-Charge. |
| 36 | M&L 80 mm thick machine pressed precast concrete interlocking paver block any shape & size confirming to IS 15658-2006, M-35 grade with grey/White cement & no pigment including PCC 1:2:4, B0 using 12.5mm graded stone aggregate in all edges of interlocking complete all as specified and directed by the Engr-in-Charge. |
| 37 | M&L PCC 1:4:8 type D2 using 40mm graded stone agg as in filling and mass concrete, Sub base/flooring including demolition of PCC in any description and in any position etc and disposal of debris and rubbish to low level area/500 mtr from site complete all as directed by the Engr-in-Charge. |
| 38 | M&L, 50mm thick sand cushioning to under concrete interlocking paver block including watering & consolidation complete all as specified |