Indian Tenders

Tender Notice

TDR 55897458
Tendering Authority Public Works Department
Tender No EE-IED/UDP/03/2026-27
Tender ID 2026_CEPWD_73597_1
Tender Brief Tender For Providing Internal Electrification Of 3 Units Additional Class Room At Kali Prasad Bari High School Under Samagra Shiksha Abhiyan Under Bokafa R.D. Block, South Tripura.
City BOKAFA SANTIRBAZAR
State Tripura
Document Fees INR 1000 /-
EMD INR 2598.0 /-
Tender Value INR 1.29 Lakhs /-
Tender Type Tender
Bidding Type Open Tender
Competition Type Indian

Tender Details

Tender for Providing Internal Electrification Of 3 Units Additional Class Room At Kali Prasad Bari High School Under Samagra Shiksha Abhiyan Under Bokafa R.D. Block, South Tripura.

Key Dates

Publish Date 09-06-2026
Last Date of Bid Submission 16-06-2026
Tender Opening Date 16-06-2026

Contact Information

Company Name Public Works Department
Contact Person EXECUTIVE ENGINEER
Address Executive Engineer Internal Electrification Division, PWD (B) Udaipur, Gomati, Tripura

BOQ Items

Name of Work:- Providing Internal Electrification of 3 units Additional Class Room at Kali Prasad Bari High School under Samagra Shiksha Abhiyan under Bokafa R.D. Block, South Tripura.
Sl. No. Item Description
1Wiring for light / fan / exhaust fan / call bell point with 2 x1.5 sq. mm pvc insulated Copper conductor cable (FR) in pvc casing and capping complete with 6/10 amps modular type switch, cover plate, surface modular switch board including connection etc as required:-
2Short Point :-
3Medium Point :-
4Long Point :-
5Providing and fixing of 3 pin 5/6 amps plug point with piano type 5/6 amps switch and socket including connection with 2x1.5 sq. mm PVC insulated Copper conductor cable (FR) on switch board, earthing the 3rd pin etc. as required:-
6Providing and fixing of 3/6 pin 16/20 amps plug point with modular type 16/20 amps switch and socket including connection with 2x2.5 sq. mm PVC insulated Copper conductor cable(FR) on surface modular switch board, earthing the 3rd pin etc. as required:-
7Wiring for circuit /Sub-main with following sizes PVC insulated copper conductor cable (FR) in PVC casing and capping etc. as required.
82 x 1.5 sq.mm:-
92 x 2.5 sq.mm:-
102 x 4 sq.mm:-
11Wiring for Circuit/Sub-main with the following sizes of PVC insulated Copper conductor cable (FR) in existing PVC casing capping/ conduit in recess/ surface including connection etc. as required.
121 x 1.5 sq.mm:-
132 x 1.5 sq.mm:-
142 x 2.5 sq.mm:-
152 x 4 sq.mm:-
16Supplying and fixing of the following sizes PVC conduit (medium gauge) on surface with all accessories etc. as required.
1719/20 mm dia
18Supplying and fixing of the following modular accessories including necessary connection etc. as required.
19Blank plate (1M):-
20Earthing with 40 mm dia G.I. Earth pipe (medium gauge) 4.5 m. long complete with masonry enclosure on top CI cover plate size 12\\"x 12\\" having locking arrangement including CC work, holes on earth pipe etc. as required:-
21Extra for using salt (5 kg) and charcoal (46kg) for pipe earth electrode as required.
22Proving and fixing / Drawing 4.06 mm dia (8 SWG) Copper wire on surface or in existing G.I / PVC / Polythene pipe for loop earthing as required.
23Supplying & fixing of 1200 mm sweep white color AC ceiling fan capacitor type double ball bearing complete with 300 mm down rod,canopies,shackles, 3nos blades, including wiring the down rod with 2x1.5 sqmm PVC insulated Copper conductor cable(FR) (ISI marked, BEE 1 star/minimum service value 4.0 m3/min/W).
24Supplying and fixing of following surface/recess mounted LED luminaries in powder coated die cast housing complete with high efficiency polycarbonate diffuser and necessary connection etc. as required (with 50000 burning hours and minimum lumen output of 100 lm/watt):-
25Surface mounted box type batten suitable for single 18/20 watt integrated LED tube lamp (without lamp):-
26Supplying and fixing of following LED Tubes, retrofit bulbs/lamps for LED luminaries including necessary connection etc. as required:-
2718/20 watt LED tube with integral driver and polycarbonate diffuser (50000 burning hours and minimum lumen output of 100lm/watt):-
289 watt LED retrofit lamp with polycarbonate body and aluminium heatsink :-
29Supplying and fixing of the following ratings switch disconnector fuse unit(main switch) made of sheet steel enclosure with all accessories including drilling holes on the board/MS clamp and necessary connection etc. as required
3032 amps 240 volts DP main switch (rewireable):-
31Supplying and installation of powder coated steel sheet enclosure (MCB DB) suitable for 240/ 415 volts MCB/ Isolator/ RCCB (SP/ SPN/ DP/TP /TPN /FP) complete with necessary bus bar, neutral link, din rail, earth bar etc i/c connection as required.
32(2+10) / 12 way SPN MCB DB (single door):-
33Supplying and fixing of following ratings MCB B/C curve having breaking capacity 10 KA in the existing MCB, DB including connection as reqd.
346 to 32 amps SP MCB:-
35Supplying & installation of isolators of following ratings in the existing MCB DB including connection etc as required:-
3640 amps DP isolator:-
37Supplying and fixing of MS frame made of (25mm x 25mm x 5mm) MS angle with necessary support by (40mm x 6mm) MS flat and 12 mm thick marine plywood on top, grouted on wall with 4 nos legs (25mmx25mmx5mm MS angle 20 cm long) finished with red oxide and 2 coat synthetic enamel paint including necessary cc work, mending the damages & painting etc as required:-
38Supplying & fixing of 40 mm dia G.I pipe (medium gauge) cross bar for fixing of ceiling fan/luminaries including painting & necessary accessories etc as required.
39Supplying & fixing of 40mmx6mm MS clamp for installation of ceiling fan/luminaries on cross bar including necessary accessories etc as required:-
40Supplying of 25 cm long ‘L’ hook made with 40mm x 6mm MS flat and fixing with necessary fasten nuts including finishing, painting etc as required. Please Enable Macros to View BoQ information

Other Detail

Information Source http://tripuratenders.gov.in
Download FileName File Description File Size
Download 767d315c-307b-42a5-ab7f-e27018864045.html Tender Documents 0 KB
Download BOQ_74902.xls Tender Documents 0 KB
Download EDNIT.pdf Tender Documents 0 KB
Download Tendernotice_1 (9).pdf Tender Documents 0 KB
Disclaimer :