| 1 | Wiring for light / fan / exhaust fan / call bell point with 2 x1.5 sq. mm pvc insulated Copper conductor cable (FR) in pvc casing and capping complete with 6/10 amps modular type switch, cover plate, surface modular switch board including connection etc as required:- |
| 2 | Short point |
| 3 | Medium point |
| 4 | Long point |
| 5 | Providing and fixing of 3 pin 6/10 amps plug point with modular type 6/10 amps switch and socket including connection with 2x1.5 sq. mm PVC insulated Copper conductor cable (FR) on surface modular switch board, earthing the 3rd pin etc. as required: |
| 6 | Providing and fixing of 3/6 pin 16/20 amps plug point with modular type 16/20 amps switch and socket including connection with 2x2.5 sq. mm PVC insulated Copper conductor cable(FR) on surface modular switch board, earthing the 3rd pin etc. as required:- |
| 7 | Wiring for circuit /Sub-main with following sizes PVC insulated copper conductor cable (FR) in PVC casing and capping etc. as required. |
| 8 | 2 x 1.5 sq.mm:- |
| 9 | 2 x 2.5 sq.mm:- |
| 10 | 2 x 4 sq.mm:- |
| 11 | Wiring for light/ fan/ exhaust fan/ call bell point with 2x1.5 sq. mm PVC insulated copper conductor cable (FR) in PVC conduit (medium gauge) recessed in slab/ wall complete with 6/10 amps modular type switch, cover plate, GI box including necessary connection etc. as required. |
| 12 | Wiring for 2 way controlling light point with 3x1.5 sq. mm PVC insulated copper conductor cable (FR) in PVC conduit (medium gauge) recessed in slab/ wall complete with 6/10 amps modular type 2 way switch, cover plate, GI box including necessary connection etc. as required. |
| 13 | Providing and fixing of 3 pin 6/10 amps plug point with modular type 6/10 amps switch and socket including connection with 2 x 1.5 sq. mm PVC insulated Copper conductor cable (FR) on modular concealed switch board with cover plate earthing the 3rd pin etc. as required. |
| 14 | Providing and fixing of 3/6 pin 16/20 amps plug point with modular type 16/20 amps switch and socket including connection with 2 x 2.5 sq. mm PVC insulated Copper conductor cable (FR) on modular concealed switch board with cover plate earthing the 3rd pin etc. as required. |
| 15 | Wiring for Circuit/Sub-main with the following sizes PVC insulated Copper conductor cable (FR) in PVC conduit (medium gauge) recessed in slab/ wall etc. as required:- |
| 16 | 2 X 1.5 + 1 X 1.5 sq mm |
| 17 | 2 X 2.5 + 1 X 1.5 sq mm |
| 18 | 2 X 4 + 1 X 1.5 sq mm |
| 19 | 4 X 6 + 2 X 2.5 sq mm |
| 20 | 4 X 10 + 2 X 4 sq mm |
| 21 | 4 X 25 + 2 X 10 sq mm |
| 22 | Supplying and fixing of the following PVC conduit (medium gauge) with all accessories on slab/recessed on wall etc as required. |
| 23 | 19/20 mm dia |
| 24 | 25 mm dia |
| 25 | Supplying and fixing of the following modular accessories including necessary connection etc. as required. |
| 26 | Bell push SP (1M) :- |
| 27 | 32 amps one way DP switch (2M):- |
| 28 | 5 step fan regulator (2M):- |
| 29 | Buzzer call bell (1M):- |
| 30 | Blank plate (1M):- |
| 31 | 20/25 amps single phase motor starter switch (2M) |
| 32 | Earthing with 40 mm dia G.I. Earth pipe (medium gauge) 4.5 m. long complete with masonry enclosure on top CI cover plate size 12\\"x 12\\" having locking arrangement including CC work, holes on earth pipe etc. as required. |
| 33 | Extra for using salt (5 kg) and charcoal (46kg) for pipe earth electrode as required. |
| 34 | Earthing with Copper earth plate 600 mm x 600 mm x 3 mm thick i/c accessories and providing masonry enclosure with CI cover plate Size 12\\"x 12\\" having locking arrangement, along with 20 mm dia (medium gauge) watering pipe including CC work etc as required:- |
| 35 | Extra for using salt (12 kg) and charcoal (96kg) for plate earth electrode as required. |
| 36 | Proving and fixing / Drawing 4.06 mm dia (8 SWG) Copper wire on surface or in existing G.I / PVC / Polythene pipe for loop earthing as required. |
| 37 | Providng and laying 15mm dia(medium gauge) G.I. pipe for drawing of 4.06mm (8SWG) dia G.I./ Copper wire for earth connection from earth electrodes etc as required. |
| 38 | Supply and fixing of 25mm x 5mm GI strip on wall/ floor of the building for horizontal/ vertical run including necessary spacers and porcelain insulators at regular intervals. |
| 39 | Supply and fixing of the following sizes GI prong with necessary nuts & bolts etc as required grouted on roof for Lightning protection. |
| 40 | G.I Prong 1000 mm long |
| 41 | Supplying & fixing of 1200 mm sweep white color AC ceiling fan capacitor type double ball bearing complete with 300 mm down rod,canopies,shackles, 3nos blades, including wiring the down rod with 2x1.5 sqmm PVC insulated Copper conductor cable(FR) (ISI marked, BEE 1 star/minimum service value 4.0 m3/min/W). |
| 42 | Supplying & installation of 400 mm sweep AC padestal fan with metal blade including connection etc as required:- |
| 43 | Supplying & installation of 400 mm sweep AC wall mounting fan with metal blade including connection etc as required:- |
| 44 | Supplying & installation of 225/230 mm sweep metalic body exhaust fan including connection etc as required:- |
| 45 | Supplying & installation of shutter for 225/230/300 mm sweep metalic body exhaust fan in the existing hole as required:- |
| 46 | Supplying & installation of metalic fan clamp box of standard size with 3mm thick bakelite/plastic cover as required:- |
| 47 | Supplying and fixing of 20 mm dia extra down rod (GI Pipe Medium Guage) with necessary hole for installation of ceiling fan as required. |
| 48 | Making different sizes of hole in the wall for fixing of exhaust fan including finishing the same with cement plastering and painting etc as required:- |
| 49 | Supplying and fixing of following luminaries complete with necessary accessories and connection etc. as required (Commercial lighting fixtures with 50,000 burning hours):- |
| 50 | Bulk head fittings with frosted/clear glass suitable for GLS or retrofit CFL/LED (without lamp) : - |
| 51 | Decorative wall mounting fancy bracket light fixture suitable for GLS or retrofit CFL/LED (without lamp) : - |
| 52 | Supplying and fixing of following surface/recess mounted LED luminaries in powder coated die cast housing complete with high efficiency polycarbonate diffuser and necessary connection etc. as required (with 50000 burning hours and minimum lumen output of 100 lm/watt):- |
| 53 | Surface mounted box type batten suitable for single 18/20 watt integrated LED tube lamp (without lamp):- |
| 54 | Recessed round/Square shaped 18 watt LED downlight with integral driver and high quality polycarbonate diffuser:- |
| 55 | Surface mounted round/Square shaped 12 watt LED downlight with integral driver and high quality polycarbonate diffuser:- |
| 56 | Supplying and fixing of following outdoor LED luminaries in powder coated die cast housing complete with heat resistant tempered glass/diffuser including necessary connection etc. as required (50000 burning hours and minimum lumen output of 100 lm/watt):- |
| 57 | 45 watt LED street light fixture with integral driver and secondary lens (IP 66):- |
| 58 | 60 watt LED street light fixture with integral driver and secondary lens (IP 66):- |
| 59 | Supplying and fixing of following LED Tubes, retrofit bulbs/lamps for LED luminaries including necessary connection etc. as required:- |
| 60 | 18/20 watt LED tube with integral driver and polycarbonate diffuser (50000 burning hours and minimum lumen output of 100lm/watt):- |
| 61 | 9 watt LED retrofit lamp with polycarbonate body and aluminium heatsink :- |
| 62 | 12 watt LED retrofit lamp with polycarbonate body and aluminium heatsink :- |
| 63 | Supplying and installation of Switch disconnector fuse unit (main switch) of the following ratings with all accessories including necessary connection etc. as required:- |
| 64 | 32 amps 240 volts DP main switch (rewireable):- |
| 65 | Supplying and installation of fuse unit kitkat/HRC/HBC of the following ratings in existing main switch/panel board including necessary connection etc as required:- |
| 66 | 100 amps kitkat porcelain fuse unit with base(rewireable):- |
| 67 | Supplying and installation of industrial plug & socket complete with metal enclosure including necessary connection etc. as required of the following ratings (without MCB):- |
| 68 | 20 amps 230/240 volts single phase suitable for SP/SPN/DP MCB:- |
| 69 | Supplying and installation of powder coated steel sheet enclosure (MCB DB) suitable for 240/ 415 volts MCB/ Isolator/ RCCB (SP/ SPN/ DP/TP /TPN /FP) complete with necessary bus bar, neutral link, din rail, earth bar etc i/c connection as required. |
| 70 | 2 way SPN MCB DB (Single door):- |
| 71 | (2+6) / 8 way SPN MCB DB (Double door):- |
| 72 | 4 way horizontal TPN MCB DB (Double door):- |
| 73 | 6 way horizontal TPN MCB DB (Double door):- |
| 74 | 4 way vertical TPN MCB DB suitable for FP MCCB incomer upto 125 amps (Double door):- |
| 75 | 6 way vertical TPN MCB DB suitable for FP MCCB incomer upto 125 amps (Double door):- |
| 76 | Supplying, installation, testing & commissioning of powder coated prewired panel board suitable for 415 volts TP MCCB as incomer & outgoing including busbar & connection as required of the following ratings & sizes:- |
| 77 | 4 way TP MCCB outgoing & TP MCCB incomer upto 400 amps:- |
| 78 | Supplying, installation, testing & commissioning of powder coated prewired digital meter module complete with ammeter, voltmeter, phase indicator lamp, control fuses, CTs, in the existing panel board including connection etc. as required:- |
| 79 | Supplying, installation, testing & commissioning of powder coated side cable module (1 pair) in the existing panel board including connection etc. as required suitable for the following sizes and ratings:- |
| 80 | 4/6 way outgoing and incomer upto 400 amps :- |
| 81 | Supplying and fixing of following ratings MCB B/C curve having breaking capacity 10 KA in the existing MCB, DB including connection as reqd. |
| 82 | 6 to 32 amps SP MCB:- |
| 83 | 40/50/63 amps TP MCB:- |
| 84 | Supplying & installation of isolators of following ratings in the existing MCB DB including connection etc as required:- |
| 85 | 40 amps DP isolator:- |
| 86 | 41 amps TP isolator:- |
| 87 | Supplying & installation of TP/FP MCCB of following ratings in the existing MCCB enclosure/ panel board including connection etc as required (Ics=100% of Icu with adjustable settings):- |
| 88 | 16 to 100 amps TP MCCB, Breaking capacity 16/18KA (Thermal Magnetic):- |
| 89 | 200 amps TP MCCB, Breaking capacity 25KA (Thermal Magnetic) :- |
| 90 | Supplying and laying of the following sizes XLPE insulated PVC sheathed aluminium conductor armoured cable with necessary connection etc as required:- |
| 91 | 3 core 4 sq mm:- |
| 92 | Supplying and fixing of Copper terminal ends (LUGS) - long barrel of following sizes: - |
| 93 | 2.5 sq mm |
| 94 | 4 sq mm |
| 95 | 6 sq mm |
| 96 | 10 sq mm |
| 97 | 25 sq mm |
| 98 | Supplying & fixing of G.I. pipe (medium gauge) bracket fabricated at suitable angle for fixing of outdoor light on wall/ RCC base with necessary MS clamp, nut, bolt etc as required:- |
| 99 | 40 mm dia:- |
| 100 | Supplying and fixing of MS frame made of (25mm x 25mm x 5mm) MS angle with necessary support by (40mm x 6mm) MS flat and 12 mm thick marine plywood on top, grouted on wall with 4 nos legs (25mmx25mmx5mm MS angle 20 cm long) finished with red oxide and 2 coat synthetic enamel paint including necessary cc work, mending the damages & painting etc as required:- |
| 101 | Supplying & fixing of 40 mm dia G.I pipe (medium gauge) cross bar for fixing of ceiling fan/luminaries including painting & necessary accessories etc as required. |
| 102 | Supplying & fixing of 40mmx6mm MS clamp for installation of ceiling fan/luminaries on cross bar including necessary accessories etc as required:- |
| 103 | Supplying of 25 cm long ‘L’ hook made with 40mm x 6mm MS flat and fixing with necessary fasten nuts including finishing, painting etc as required. |
| 104 | Excavation of earth for cable trench of 800mm depth & 300mm width in all kinds of soil including back filling of cable trench with the excavated soil with 20cm layer of sand, 3.5 nos bricks per metre for protection including ramming, consolidating to the original shape as per dirrection of Site Engineer :- |
| 105 | Drawing of armoured/un-armoured cable with proper saddling etc as required:- Please Enable Macros to View BoQ information |