| 1 | Chipping of RCC/Stone masonary walls/ plastering surfaces deep average 10mm width in base with in all leads aand lifts as per the direction of the Engineer in Charge. |
| 2 | Repair in patch work with 15 mm cement plaster in 1:4 (1 Cement: 4 Sand) single coat on rough side of brick/ stone masonry for interior plastering upto floor two level including arries, internal rounded angles, chamfers and rounded angles not exceeding 80mm in grith and finished even and smooth in cement mortar 1:4 (1 Cement: 4 Sand) including all leads and lifts and carriage of material at site and as per the direction and entire |
| 3 | Cement concrete flooring 1:2:4 (cement: 2 Sand: 4 graded stone aggregate 20 mm nominal size) laid in one layer finished with a floating coat of neat cement 50mm thick with in all leads and lifts as per the direction of the Engineer Incharge. |
| 4 | Providing & fixing panelled glazed or panelled & glazed shutters for doors windows and clerestory windows including black enamelled iron butt hinges with necessary screws in 2nd class deodar wood (40 mm thick) |
| 5 | Steel work in single sections including cutting, hoisting, fixing in position and applying a priming coat of red lead paint in R.S. Joists,channels, angles, tees etc. with in all leads and lifts as directed by the Engineer Incharge |
| 6 | Providing and laying cement concrete 1:2:4 (cement :2 Sand: 4 graded stone aggregate 20 mm (Twenty millimeter nominal size) and curing complete excluding cost of form work and reinforcement for reinforced concrete work in Foundation and Plinth with in all leads and lifts as per the direction of the Engineer in Charge. |
| 7 | 15 mm thick cement plaster in single coat on fair sides of brick/concrete/ stone walls for interior plastering upto floor two level including arises internal rounded angles not exceeding 80mm girth and finished even smooth in cm 1:3 (cement: 3sand) within all leads and lifts and as directed by the Engineer-in-charge. |
| 8 | 6 mm thick cement plaster in ceiling in cm 1:3 (cement: 3sand) within all leads and lifts and as directed by the Engineer-in-charge. |
| 9 | Providing and laying cement concrete 1:3:6 (cement: 3 sand: 6 graded stone aggregate 40mm (Forty millimeter nominal size) and curing complete excluding cost of from work in foundation and plinth with in all leads & lifts as per entire satisfication of Engineer-in-Charge. |
| 10 | Hirmachi color wash on undecorated wall surface (two coat) give an even shade i/c throughly brooming the surface to remove all dirt, mortar drops and othe foreign matter with in all leads and lifts as per the directions of the Engineer in charge. |
| 11 | Removing white wash or colour wash by steel wire brushing and/or scrapping sand papering and preparing the wall surface smooth including necessary repair to scratches complate. |
| 12 | Distempering (two coats) with oil bound washable distemper of approved brand and manufacture and of required shade for interior painting on undecorated wall surfaces to give an even shade over and including a priming coat with distemper primer of approved brand and manufacture after thoroughly brushing the surface to remove all dirt, dust and other foreign matter etc. on interior walls of Plant buildings of STP Zone 2 and Zone 3 complete in all respect as per direction of Engineer-in-Charge with in all leads and lifts. |
| 13 | Painting two coats (excluding priming coat) of approved make on new steel and other metal surface under coat with ready mixed paint brusing to give an even shade including cleaning the surface all dirt,dust and other foreign matter complete in all respect within all leads and lifts as per direction & to the entire satisfaction of Engineer-in-charge. With readymixed paint other than white. |
| 14 | Lifting of filter media from existing filter tank and stacking the same with in all leads and lifts and entire satisfection of Engineer-in-Charge. |
| 15 | Top Layer: Effective size 0.2mm to 0.4mm and uniformity 3.00 |
| 16 | Second layer: Bottom layer broken stone 3mm to 6mm |
| 17 | Third Layer: Bajri 6mm to 20mm |
| 18 | Fourth Layer: Bajri 20mm to 25mm |
| 19 | Bottom layer broken stone 50mm to 75mm |
| 20 | Providing and placing horizontal layers filtering media duly graded screened washed and cleaned as specified by the Engineer Incharge with in all leads and lifts. |
| 21 | Bajri 6mm to 20mm |
| 22 | Course 3mm to 6mm |
| 23 | Placing of old horizontal layers filtering media duly graded screened washed and cleaned as specified by the Engineer Incharge with in all leads and lifts. |
| 24 | Bottom layer broken stone 50mm to 75mm |
| 25 | Fourth Layer: Bajri 20mm to 25mm |
| 26 | Third Layer: Bajri 6mm to 20mm |
| 27 | Second layer: Bottom layer broken stone 3mm to 6mm |
| 28 | Excavation in earth work and disposal of all excavated earth up to a lead of 20mtrs (twenty metres) and lift up to 1.50 mrs (one point fifty metres) disposing earth to be leveled and neatly dressed |
| 29 | Providing & Laying cement concrete 1:6:12(1ccement :6 sand: 12 graded stone aggregate 40 mm nominal size) and curing complete excluding cost of form work in foundation and plinth with in all leads and lifts as per the directions of the Engineer in charge. |
| 30 | Providing andf laying cement concrete 1:5:10 (1 cement :5 sand : 10 graded stone aggregate 40 mm nominal size ) with 15% plum concrete and curing complete excluding cost of form work in retaining walls/breast walls,the size of plums shall usually be 150 mm to 300 mm as per H.P.P.W.D Specification. |
| 31 | Providing from work steel plates 3.15 mm thick welded with angle iron in frame 30x30x5 mm so as to give a fair finish i/c centering, shuttering, strutting and propping etc. with wooded battens & ballies, height of propping and centring below supporting floor to ceilling not exceeding 4 meters and removal of the same for in situ reinforced concrete and plain concrete work with in all leads aand lifts as per the direction of the Engineer in Charge. |
| 32 | Vertical surfaces such as walls (any thickness) partitions and the like including attached pillasters, buttress, plinth and string couress and the like with in all leads aand lifts as per the direction of the Engineer in Charge. |
| 33 | Boulder filling behind R/wall & B/wall within all leads and lifts and as directed by the Engineer-in-charge. |
| 34 | Providing and fixing of Finolex pipe 50mm dia. In R/Wall including all re-fitting i/e elbowa, sockets etc. with in all leads aand lifts as per the direction of the Engineer in Charge. Please Enable Macros to View BoQ information |