Indian Tenders

Tender Notice

TDR 55897290
Tendering Authority Uttar Pradesh Tourism Development Corporation
Tender No 8267/Pari-5/Nivida Suchna/2025-26
Tender ID 2026_STDCL_1146324_3
Tender Brief Tender For Tourism Development Work Of Shri Ramjanaki Temple, Kotawari In Shahjahanpur District.
City Shahjahanpur
State Uttar Pradesh
Document Fees INR 5900 /-
EMD INR 653000.0 /-
Tender Value INR 91.42 Lakhs /-
Tender Type Tender
Bidding Type Open Tender
Competition Type Indian

Tender Details

Tender For Tourism Development Work Of Shri Ramjanaki Temple, Kotawari In Shahjahanpur District.-1 Earth Work In Excavation By Mechanical Means (Hydraulic Excavator)/ Manual Means Over Areas (Exceeding 30 Cm In Depth, 1.5 M In Width As Well As 10 Sqm On Plan) Including Getting Out And Disposal Of Excavated Earth Lead Upto 50 M And Lift Upto 1.5 M, As Directed By Engineer-Incharge. All Kinds Of Soil Dsr-2.6.1 170.25 Cum 133.12 127.80 21757.52 In All Kind Of Soil Upto 1.5M To 3.0M. Depth 2.6.1+2.26.1 18.74 Cum 228.22 219.09 4106.24 In All Kind Of Soil Upto 3.0M To 4.5M. Depth 2.6.1+(2.26.1* 2) 6.37 Cum 323.31 310.38 1977.88 2 Excavation Of Foundation In Ordinary Soil (Loam Clay Or Sand) Including Lift Upto 1.50 Meter And Lead Upto 30 Meter And Including Filling, Watering And Ramming Of Excavated Earth Into The Trenches Or Into The Space Between The Building And Sides Of Foundation Trenches Or Into The Plinth And Removal And Disposal Of Sur-Plus Earth As Directed By The Engineer Incharge Up To A Distance Of 30 Meters From The Foundation Trenches. Dsr-2.1.1 35.61 Cum 97.38 93.49 3329.14 3 Filling Available Excavated Earth (Excluding Rock) In Trenches, Plinth, Sides Of Foundations Etc. In Layers Not Exceeding 20Cm In Depth, Consolidating Each Deposited Layer By Ramming And Watering, Lead Up To 50 And For All Lift. Dsr-2.25 8.70 Cum 147.00 141.12 1227.84 4 Excavating, Supplying And Filling Of Local Earth (Including Royalty) By Mechanical Transport Upto A Lead Of 5Km Also Including Ramming And Watering Of The Earth In Layers Not Exceeding 20 Cm In Trenches, Plinth, Sides Of Foundation Etc. Complete Dsr-2.25(A) 55.60 Cum 525.36 504.34 28041.40 5 Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level : 1:4:8 (1 Cement : 4 Coarse Sand (Zone-Iii) Derived From Natural Sources : 8 Graded Stone Aggregate 40 Mm Nominal Size Derived From Natural Sources) Dsr-4.1.8 70.78 Cum 5108.83 4904.47 347162.56 6 Supplying And Filling In Plinth With Sand Under Floors, Including Watering, Ramming, Consolidating And Dressing Complete. Dsr-2.27 26.31 Cum 1592.76 1529.05 40229.27 7 Diluting And Injecting Chemical Emulsion For Postonstructional Anti-Termite Treatment (Excluding The Cost Of Chemical Emulsion) : Treatment Of Soil Under Existing Floors Using Chemical Emulsion @ One Litre Per Hole, 300 Mm Apart Including Drilling 12 Mm Diameter Holes And Plugging With Cement Mortar 1 :2 (1 Cement : 2 Coarse Sand) To Match The Existing Floor: With Chlorpyriphos/Lindane E.C. 20% With 1% Concentration Dsr-2.35.3.1 194.47 Sqm 232.53 223.23 43411.24 8 Reinforced Cement Concrete Work In Beams, Suspended Floors, Roofs Having Slope Up To 15° Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Window Sills, Staircases And Spiral Stair Cases Above Plinth Level Up To Floor Five Level, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement With 1:1.5:3 (1 Cement : 1.5 Coarse Sand(Zone-Iii) Derived From Natural Sources : 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources). Dsr-5.3 82.66 Cum 8628.83 8283.68 684729.10 9 Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement - All Work Up To Plinth Level : 1:1.5:3 (1 Cement : 1.5 Coarse Sand (Zone-Iii) Derived From Natural Sources : 3 Graded Stone Aggregate 20 Mm Nominal Size De Rived From Natural Sources) Footing Dsr-5.1.2 21.98 Cum 6784.08 6512.72 143149.60 10 Reinforced Cement Concrete Work In Walls (Any Thickness), Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc. Above Plinth Level Up To Floor Five Level, Excluding Cost Of Centering, Shuttering, Finishing And Reinforcement : 1:1.5:3 (1 Cement : 1.5 Coarse Sand(Zone-Iii) Derived From Natural Sources : 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources) Dsr-5.2.2 22.97 Cum 8139.44 7813.86 179484.39 Abstract Of Cost Delhi Schedule Of Rate Effective From 12/07/2023 X (0.735X106/107X1.03) Has Been Followed. Proposed Tourism Development Of Ramjanki Temple At Kotawari, Tilhar, Sahjahanpur, U.P. 11 Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For Lintels, Beams, Plinth Beams, Girders, Bressumers And Cantilevers Dsr-5.9.5 257.49 Sqm 552.28 530.19 136518.66 12 Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For Suspended Floors, Roofs, Landings, Balconies And Access Platform Dsr-5.9.3 407.10 Sqm 695.41 667.60 271778.96 13 Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For Foundations, Footings, Bases Of Columns, Etc. For Mass Concrete Dsr-5.9.1 63.96 Sqm 294.10 282.34 18058.37 14 Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For Columns, Pillars, Piers, Abutments, Posts And Struts Dsr-5.9.6 208.86 Sqm 720.95 692.11 144554.66 15 Brick Work With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 In Foundation And Plinth In: Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) Dsr-6.1.1 16.84 Cum 5527.80 5306.69 89341.45 16 Brick Work With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 In Foundation And Plinth In: Cement Mortar 1:6 (1 Cement : 6 Coarse Sand) Dsr-6.1.2 51.30 Cum 5349.01 5135.05 263427.92 17 Providing And Laying Damp-Proof Course 50Mm Thick With Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand (Zone-Iii) Derived From Natural Sources : 4 Graded Stone Aggregate 20Mm Nominal Size Derived From Natural Sources). Dsr-4.11 2.14 Sqm 371.80 356.93 763.83 18 Providing & Applying A Coat Of Residual Petroleum Bitumen Of Grade Of Vg-10 Of Approved Quality Using 1.7Kg Per Square Metre On Damp Proof Course After Cleaning The Surface With Brushes And Finally With A Piece Of Cloth Lightly Soaked In Kerosene Oil. Dsr-4.13 44.55 Sqm 109.61 105.22 4687.75 19 Brick Work With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 In Superstructure Above Plinth Level Up To Floor V Level In All Shapes And Sizes In : Cement Mortar 1:6 (1 Cement : 6 Coarse Sand) Dsr-6.4.2 80.04 Cum 6829.23 6556.06 524747.32 20 Half Brick Masonry With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 In Superstructure Above Plinth Level Up To Floor V Level. Cement Mortar 1:4 (1 Cement :4 Coarse Sand) Dsr-6.13.2 60.18 Sqm 842.82 809.11 48692.17 21 Steel Reinforcement For R.C.C. Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Above Plinth Level. Thermo-Mechanically Treated Bars Of Grade Fe-500D Or More Dsr-5.22A.6 186.64 Qtl 8088.48 7764.94 1449250.34 22 15 Mm Cement Plaster On Plinth Side Of Single Or Half Brick Wall Of Mix : 1:4 (1 Cement: 4 Coarse Sand) Dsr-13.5.1 65.74 Sqm 308.80 296.45 19488.62 23 15 Mm Cement Plaster On Rough Side Of Single Or Half Brick Wall Of Mix: 1:6 (1 Cement: 6 Coarse Sand) Dsr-13.5.2 252.10 Sqm 296.50 284.64 71758.35 24 12 Mm Cement Plaster Of Mix : 1:6 (1 Cement: 6 Coarse Sand) Dsr-13.4.2 609.85 Sqm 257.73 247.42 150888.63 25 Add For Plaster Drip Course/ Groove In Plastered Surface Or Moulding To R.C.C. Projections. Dsr-5.30 315.01 Rm 58.80 56.45 17781.09 26 Cement Concrete Flooring 1:2:4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate) Finished With A Floating Coat Of Neat Cement, Including Cement Slurry, But Excluding The Cost Of Nosing Of Steps Etc. Complete. 40 Mm Thick With 20 Mm Nominal Size Stone Aggregate Dsr-11.3.1 29.40 Sqm 460.63 442.21 13000.95 27 Cement Plaster Skirting Up To 30 Cm Height, With Cement Mortar 1:3 (1 Cement : 3 Coarse Sand), Finished With A Floating Coat Of Neat Cement.18 Mm Thick Dsr-11.6.1 3.35 Sqm 496.52 476.66 1596.81 26 Providing And Laying Vitrified Floor Tiles In Different Sizes (Thickness To Be Specified By The Manufacturer) With Water Absorption Less Than 0.08% And Conforming To Is: 15622, Of Approved Make, In All Colours And Shades, Laid On 20 Mm Thick Cement Mortar 1:4 (1 Cement : 4 Coarse Sand), Jointing With Grey Cement Slurry @ 3.3 Kg/ Sqm Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete. Size Of Tile 600X600 Mm Dsr-11.41.2 137.75 Sqm 1165.05 1118.45 154065.99 27 Providing And Laying Vitrified Tiles In Different Sizes (Thickness To Be Specified By Manufacturer), With Water Absorption Less Than 0.08 % And Conforming To |.S. 15622, Of Approved Make, In All Colours & Shade, In Skirting, Riser Of Steps, Over 12 Mm Thick Bed Of Cement Mortar 1:3 (1 Cement: 3 Coarse Sand), Jointing With Grey Cement Slurry @ 3.3 Kg/ Sqm Including Grouting The Joint With White Cement & Matching Pigments Etc. Complete. Size Of Tile 600X600 Mm Dsr-11.46.2 10.17 Sqm 1217.25 1168.56 11884.22 28 Providing And Fixing 1St Quality Ceramic Glazed Floor Tiles Conforming To Is : 15622 (Thickness To Be Specified By The Manufacturer ) Of Approved Make In All Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Engineer-In-Charge In Skirting, Risers Of Steps And Dados Over 12 Mm Thick Bed Of Cement Mortar 1:3 (1 Cement: 3 Coarse Sand) And Jointing With Grey Cement Slurry @ 3.3Kg Per Sqm Including Pointing In White Cement Mixed With Pigment Of Matching Shade Complete. Dsr-11.37A 148.53 Sqm 812.00 779.52 115781.77 29 Providing And Laying Rectified Glazed Ceramic Floor Tiles Of Size 300X300 Mm Or More (Thickness To Be Specified By The Manufacturer), Of 1St Quality Conforming To Is : 15622, Of Approved Make, In Colours White, Ivory, Grey, Fume Red Brown, Laid On 20 Mm Thick Cement Mortar 1:4 (1 Cement: 4 Coarse Sand), Jointing With Grey Cement Slurry @ 3.3Kg/ Sqm Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete. Dsr-11.39 4.40 Sqm 997.47 957.57 4213.30 30 Chequerred Precast Cement Concrete Tiles 22 Mm Thick In Footpath & Courtyard, Jointed With Neat Cement Slurry Mixed With Pigment To Match The Shade Of Tiles, Including Rubbing And Cleaning Etc. Complete, On 20 Mm Thick Bed Of Cement Mortar 1:4 (1 Cement: 4 Coarse Sand). Ordinary Cement Without Any Pigment 11.20.4 6.12 Sqm 792.24 760.55 4654.54 31 Providing And Fixing Panelled Or Panelled And Glazed Shutters For Doors,Windows And Clerestory Windows, Fixing With Butt Hinges Of Required Size With Necessary Screws, Excluding Panelling Which Will Be Paid For Separately, All Complete As Per Direction Of Engineer-In-Charge. (Note: Butt Hinges And Necessary Screws Shall Be Paid Separately) 35 Mm Thick Dsr-9.5.1.1 6.30 Sqm 3083.86 2960.50 18651.18 32 Providing And Fixing Panelled Or Panelled And Glazed Shutters For Doors,Windows And Clerestory Windows, Fixing With Butt Hinges Of Required Size With Necessary Screws, Excluding Panelling Which Will Be Paid For Separately, All Complete As Per Direction Of Engineer-In-Charge. (Note: Butt Hinges And Necessary Screws Shall Be Paid Separately) 30 Mm Thick Dsr-9.5.1.2 83.22 Sqm 2810.38 2697.97 224524.67 33 Providing And Fixing Isi Marked Flush Door Shutters Conforming To Is : 2202 (Part I) Non-Decorative Type, Core Of Block Board Construction With Frame Of 1St Class Hard Wood And Well Matched Commercial 3 Ply Veneering With Vertical Grains Or Cross Bands And Face Veneers On Both Faces Of Shutters: 35 Mm Thick Including Isi Marked Stainless Steel Butt Hinges With Necessary Screws Dsr-9.21.1 15.33 Sqm 1794.43 1722.65 26408.23 34 Providing 40X5 Mm Flat Iron Hold Fast 40 Cm Long Including Fixing To Frame With 10 Mm Diameter Bolts, Nuts And Wooden Plugs And Embedding In Cement Concrete Block 30X10X15Cm 1:3:6 Mix (1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20Mm Nominal Size). Dsr-9.53 128.00 Nos 171.63 164.77 21090.11 35 Providing And Fixing M.S. Grills Of Required Pattern In Frames Of Windows Etc. With M.S. Flats, Square Or Round Bars Etc. Including Priming Coat With Approved Steel Primer All Complete. Fixed To Steel Windows By Welding Dsr-9.48.1 937.05 Kg 164.32 157.75 147816.54 36 Providing And Fixing T-Iron Frames For Doors, Windows And Ventilators Of Mild Steel Tee-Sections, Joints Mitred And Welded, Including Fixing Of Necessary Butt Hinges And Screws And Applying A Priming Coat Of Approved Steel Primer. Fixing With 15X3 Mm Lugs 10 Cm Long Embedded In Cement Concrete Block 15X10X10 Cm Of C.C. 1:3:6 (1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20 Mm Nominal Size). Dsr-10.13.1 100.80 Kg 106.27 102.02 10283.67 37 Providing And Fixing Angle Iron Frames For Doors, Windows And Ventilators Of Mild Steel Angle Sections Of Size 35X35X5 Mm, Joints Mitred And Welded By Angle Iron 35X35X5 Mm Or 35X 5 Mm Flat Pieces To The Existing T-Iron Frame Or To The Wall With Dash Fastener, Including Fixing Of Necessary Butt Hinges And Screws And Applying A Priming Coat Of Approved Steel Primer, All Complete As Per The Direction Of Engineer-In-Charge. Dsr-10.31 125.00 Kg 97.87 93.96 11744.60 38 Providing And Fixing Stainless Steel ( Grade 304) Railing Made Of Hollow Tubes, Channels, Plates Etc., Including Welding, Grinding, Buffing, Polishing And Making Curvature (Wherever Required) And Fitting The Same With Necessary Stainless Steel Nuts And Bolts Complete, I/C Fixing The Railing With Necessary Accessories & Stainless Steel Dash Fasteners , Stainless Steel Bolts Etc., Of Required Size, On The Top Of The Floor Or The Side Of Waist Slab With Suitable Arrangement As Per Approval Of Engineer-Incharge, (For Payment Purpose Only Weight Of Stainless Steel Members Shall Be Considered Excluding Fixing Accessories Such As Nuts, Bolts, Fasteners Etc.). Dsr 10.28 133.33 Kg 579.28 556.11 74146.05 39 Providing Wood Work In Frames Of Doors, Windows, Clerestory Windows And Other Frames, Wrought Framed And Fixed In Position With Hold Fast Lugs Or With Dash Fasteners Of Required Dia & Length (Hold Fast Lugs Or Dash Fastener Shall Be Paid For Separately).(Sal Wood) Dsr-9.1.2 1.61 Cum 87387.28 83891.79 135065.79 40 Fixing Of Door, Windows/Ventilators Chaukhats In Position. (A) Door Chaukhats Above 1.5 Sqm To 5.0Sqm Mr 19.00 Nos 150.00 144.00 2736.00 (B) Window Chaukhats Above 1.5 Sqm 12.00 Nos 100.00 96.00 1152.00 (C) Ventilator Chaukhats 7.00 Nos 50.00 48.00 336.00 41 Finishing Walls With Premium Acrylic Smooth Exterior Paint With Silicone Additives Of Required Shade: New Work (Two Or More Coats Applied @ 1.43 Ltr/10 Sqm Over And Including Priming Coat Of Exterior Primer Applied @ 2.20 Kg/10 Sqm) Dsr-13.47.1 407.00 Sqm 128.32 123.19 50137.46 42 Distempering With Oil Bound Washable Distemper Of Approved Brand And Manufacture To Give An Even Shade : New Work (Two Or More Coats) Over And Including Water Thinnable Priming Coat With Cement Primer Dsr-13.41.1 434.15 Sqm 139.23 133.66 58030.01 43 Providing And Applying White Cement Based Putty Of Average Thickness 1 Mm, Of Approved Brand And Manufacturer, Over The Plastered Wall Surface To Prepare The Surface Even And Smooth Complete. Dsr-13.80 841.15 Sqm 117.03 112.35 94505.07 44 Providing And Fixing Isi Marked Oxidised M.S. Sliding Door Bolts With Nuts And Screws Etc. Complete :250X16 Mm Dsr-9.62.2 11.00 Nos 145.27 139.46 1534.05 45 Providing And Fixing Isi Marked Oxidised M.S. Tower Bolt Black Finish, (Barrel Type) With Necessary Screws Etc. Complete : 250X10 Mm Dsr-9.63.1 21.00 Nos 62.92 60.41 1268.53 200X10 Mm Dsr-9.63.2 65.00 Nos 52.05 49.97 3247.81 46 Providing And Fixing Isi Marked Oxidised M.S. Handles Conforming To Is:4992 With Necessary Screws Etc. Complete :100 Mm Dsr-9.66.2 54.00 Nos 24.41 23.44 1265.50 47 Providing And Fixing Bright Finished Brass Hanging Type Floor Door Stopper With Necessary Screws, Etc. Complete Dsr-9.82 1.00 Nos 91.23 87.59 87.59 48 Providing And Laying Integral Cement Based Water Proofing Treatment Including Preparation Of Surface As Required For Treatment Of Roofs, Balconies, Terraces Etc Consisting Of Following Operations: (A) Applying A Slurry Coat Of Neat Cement Using 2.75 Kg/Sqm Of Cement Admixed With Water Proofing Compound Conforming To Is. 2645 And Approved By Engineer-In-Charge Over The Rcc Slab Including Adjoining Walls Upto 300 Mm Height Including Cleaning The Surface Before Treatment. (B) Laying Brick Bats With Mortar Using Broken Bricks/Brick Bats 25 Mm To 115 Mm Size With 50% Of Cement Mortar 1:5 (1 Cement : 5 Coarse Sand) Admixed With Water Proofing Compound Conforming To Is : 2645 And Approved By Engineerin- Charge Over 20 Mm Thick Layer Of Cement Mortar Of Mix 1:5 (1 Cement :5 Coarse Sand ) Admixed With Water Proofing Compound Conforming To Is : 2645 And Approved By Engineerin- Charge To Required Slope And Treating Similarly The Adjoining Walls Upto 300 Mm Height Including Rounding Of Junctions Of Walls And Slabs. (C) After Two Days Of Proper Curing Applying A Second Coat Of Cement Slurry Using 2.75 Kg/ Sqm Of Cement Admixed With Water Proofing Compound Conforming To Is : 2645 And Approved By Engineer-In-Charge. (D) Finishing The Surface With 20 Mm Thick Jointless Cement Mortar Of Mix 1:4 (1 Cement :4 Coarse Sand) Admixed With Water Proofing Compound Conforming To Is : 2645 And Approved By Engineer-In-Charge Including Laying Glass Fibre Cloth Of Approved Quality In Top Layer Of Plaster And Finally Finishing The Surface With Trowel With Neat Cement Slurry And Making Pattern Of 300X300 Mm Square 3 Mm Deep. (E) The Whole Terrace So Finished Shall Be Flooded With Water For A Minimum Period Of Two Weeks For Curing And For Final Test.“All Above Operations To Be Done In Order And As Directed And Specified By The Engineer-In-Charge : With Average Thickness Of 120 Mm And Minimum Thickness At Khurra As 65 Mm Dsr-22.7.1 198.55 Sqm 1263.41 1212.87 240815.58 49 Finishing With Deluxe Multi Surface Paint System For Interiors And Exteriors Using Primer As Per Manufacturers Specifications : Painting Steel Work With Deluxe Multi Surface Paint To Give An Even Shade. Two Or More Coat Applied @ 0.90 Ltr/ 10 Sqm Over An Under Coat Of Primer Applied @ 0.80 Ltr/ 10 Sqm Of Approved Brand And Manufacture Dsr-13.48.3 144.65 Sqm 128.02 122.90 17777.47 50 Finishing With Deluxe Multi Surface Paint System For Interiors And Exteriors Using Primer As Per Manufacturers Specifications : Painting Wood Work With Deluxe Multi Surface Paint Of Required Shade. Two Or More Coat Applied @ 0.90 Ltr/10 Sqm Over An Under Coat Of Primer Applied @0.75 Ltr/10 Sqm Of Approved Brand And Manufacture Dsr-13.48.2 209.70 Sqm 132.18 126.90 26610.03 51 Providing & Fixing Panes Of Glass With Equal Or Equivalent I.S.I Marked Quality Putty. Brads And Springs And Including Supply Of All Materials And Labour Etc Complete . 3.8 To 4.7 Mm Thick Dsr-10.30.1 44.76 Sqm 805.96 773.72 34631.80 52 Supply And Fixing Of Drop Down Rail / Grab Bars Mr 4.00 Nos. 4400.00 4224.00 16896.00 53 Providing, Driving With Hydraulic Piling Rigs With Power Units And Installing Driven Cast-In-Situ Reinforced Cement Concrete Piles Of Grade M-25 Of Specified Diameter And Length Below The Pile Cap, To Carry Safe Working Load Not Less Than Specified, Excluding The Cost Of Steel Reinforcement But Including The Cost Of Shoe And The Length Of Pile To Be Embedded In The Pile Cap Etc. All Complete. (Length Of Pile For Payment Shall Be Measured From Top Of Shoe To The Bottom Of Pile Cap) : 400 Mm Dia Piles Dsr-20.1.1 48.00 Rm 2075.18 1992.17 95624.30 54 Stone Work (Machine Cut Edges) For Wall Lining Etc. (Veneer Work) Upto 10 Metre Height, Backing Filled With A Grout Of Average 12 Mm Thick Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) Including Pointing In White Cement Mortar 1:2 (1 White Cement : 2 Stone Dust) With An Admixture Of Pigment Matching The Stone Shade : (To Be Secured To The Backing And The Sides By Means Of Cramps And Pins Which Shall Be Paid For Separately) : 30 Mm Thick Dsr-8.14.1.5 50.74 Sqm 3971.79 3812.92 193478.98 55 Stone Work In Plain Ashlar In Super Structure Upto Floor Five Level In Cement Mortar 1:6 (1 Cement : 6 Coarse Sand) Including Pointing With Cement Mortar 1:2 (1 White Cement : 2 Stone Dust) With An Admixture Of Pigment Matching The Stone Shade Both Face Dressed Red Sand Stone Dsr-7.12.1.1 3.56 Cum 51218.78 49170.03 175241.97 56 Extra For Stone Work Ashlar Sunk Or Moulded Or Sunk And Moulded Or Carved In : Triangular Or Square Or Rectangular Pillars Dsr-7.21.1 3.56 Cum 2834.15 2720.79 9696.89 57 Providing And Fixing Stainless Steel Cramps Of Required Size And Shape For Anchoring Stone Wall Lining To The Backing Or Securing Adjacent Stones In Stone Wall Lining In Cement Mortar 1:2 (1 Cement : 2 Coarse Sand), Including Making The Necessary Chases In Stone And Holes In Walls Wherever Required. Dsr-8.15 99.58 Kg. 535.78 514.35 51219.04 58 Stone Work (Machine Cut Edges) For Wall Lining Etc. (Veneer Work) Upto 10 Metre Height, Backing Filled With A Grout Of Average 12 Mm Thick Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) Including Pointing In White Cement Mortar 1:2 (1 White Cement : 2 Stone Dust) With An Admixture Of Pigment Matching The Stone Shade : (To Be Secured To The Backing And The Sides By Means Of Cramps And Pins Which Shall Be Paid For Separately) :Red Sand Stone - Exposed Face Machine Cut And Table Rubbed With Rough Backing. 50Mm Dsr 8.14.1.3 37.80 Sqm. 4342.28 4168.59 157572.62 59 Providing And Fixing Copper Pins 7.5 Cm Long 6 Mm Diameter For Securing Adjacent Stones In Stone Wall Lining In Cement Mortar 1:2 (1 Cement : 2 Coarse Sand), Including Making The Necessary Chases. Dsr 8.16 30.00 Nos. 32.92 31.61 948.21 60 Providing And Fixing Stone Jali 40 Mm Thick Throughout In Cement Mortar 1:3 (1 Cement : 3 Coarse Sand), Including Pointing In White Cement Mortar 1:2 (1 White Cement : 2 Stone Dust) With An Admixture Of Pigment, Matching The Stone Shade, Jali Slab Without Any Chamfers Etc. Red Sand Stone Dsr 7.33.1 4.50 Sqm. 11198.29 10750.35 48376.59 61 Stone Work, Plain In Copings, Cornices, String Courses And Plinth Courses, Upto 75 Mm Thick In Cement Mortar 1:6 (1 Cement : 6 Coarse Sand), Including Pointing With White Cement Mortar 1:2 (1 White Cement : 2 Stone Dust) With An Admixture Of Pigment Matching The Stone Shade.: Red Sand Stone Dsr 7.32.1 0.47 Cum. 70303.46 67491.32 31720.92 62 Carving & Engraving Work On Red Sand Stone (Labour Only) M.R. 9.73 Sqm. 15615.00 14990.40 145856.59 63 Manufacturing, Supplying And Fixing Retro Reflective Overhead Signage Boards Made Up Of 2 Mm Thick Aluminium Sheet, Face To Be Fully Covered With High Intensity And Encapsulated Lens Type Heat Activated Retro Reflective Sheeting Conforming To Type - Iii Of Astm-D-4956-01 As Approved By Engineer-In-Charge, Letters, Borders Etc. As Per Irc : 67-2001 In Silver White With Blue Colour Back Ground And With High Intensity Grade, Pasted On Substrate By Pressure Sensitive Adhesive Backing Which Shall Be Activated By Applying Pressure Conforming To Class Ii Of Astm-D-4956-01 And Fixing The Same To The Plate Of Structural Frame Work By Means Of Suitable Sized Aluminium Alloys, Rivets Or Bolts & Nuts @ 300 Mm Centre To Centre All Along The Periphery As Well As In Two Vertical Rows Along With Theft Resistant Measures, Including The Cost Of Painting With Two Or More Coats Of Epoxy Paint In Grey Colour On The Back Side Of Aluminium Sheet Including Appropriate Priming Coat. The Rate Includes The Cost Of Rounding Off The Corners, Lowering Down The Structural Frame Work From The Gantry, Fixing And Erecting The Same In Position All Complete As Per Drawings, Specification And Direction Of The Engineerincharge.( Structural Frame Work Including M.S. Plate To Be Provided Separately. Rectangular Area Of The Sheet Only Shall Be Measured For Payment). Overhead Informatory Road Signage Dsr 16.60.1 8.64 Sqm. 4409.78 4233.39 36576.45 64 Providing And Fixing 18 Mm Thick Gang Saw Cut, Mirror Polished, Premoulded And Prepolished, Machine Cut For Kitchen Platforms, Vanity Counters, Window Sills, Facias And Similar Locations Of Required Size, Approved Shade, Colour And Texture Laid Over 20 Mm Thick Base Cement Mortar 1:4 (1 Cement : 4 Coarse Sand), Joints Treated With White Cement, Mixed With Matching Pigment, Epoxy Touch Ups, Including Rubbing, Curing, Moulding And Polishing To Edges To Give High Gloss Finish Etc. Complete At All Levels. Dsr 8.2.2.2 34.45 Sqm 3852.10 3698.01 127396.50 65 Making Plinth Protection 50 Mm Thick Of Cement Concrete 1:3:6 (1 Cement : 3 Coarse Sand (Zone-Iii) Derived From Natural Sources : 6 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources) Over 75 Mm Thick Bed Of Dry Brick Ballast 40 Mm Nominal Size, Well Rammed And Consolidated And Grouted With Fine Sand, Including Necessary Excavation, Levelling & Dressing & Finishing The Top Smooth. Dsr-4.17 6.00 Sqm 561.96 539.48 3236.87 66 Providing And Laying Factory Made Chamfered Edge Cement Concrete Paver Blocks In Footpath, Parks, Lawns, Drive Ways Or Light Traffic Parking Etc, Of Required Strength, Thickness & Size/ Shape, Made By Table Vibratory Method Using Pu Mould, Laid In Required Colour & Pattern Over 50 Mm Thick Compacted Bed Of Sand, Compacting And Proper Embedding/Laying Of Inter Locking Paver Blocks Into The Sand Bedding Layer Through Vibratory Compaction By Using Plate Vibrator, Filling The Joints With Sand And Cutting Of Paver Blocks As Per Required Size And Pattern, Finishing And Sweeping Extra Sand. Complete All As Per Direction Of Engineer-In-Charge.80 Mm Thick C.C. Paver Block Of M-35 Grade With Approved Colour Design And Pattern Dsr-16.91.2 207.07 Sqm 818.60 785.85 162723.31 1 Providing And Fixing Water Closet Squatting Pan (Indian Type W.C. Pan) With 100Mm Sand Cast Iron P Or S Trap, 10 Litre Low Level White P.V.C. Flushing Cistern With Manually Controlled Device (Handle Lever) Conforming To Is : 7231, With All Fitting And Fixtures Completed Including Cutting And Making Good The Walls And Floors Wherever Required.White Vitreous China Orissa Pattern W.C. Pan Of Size 580X440 Mm With Integral Type Foot Rests 17.1.1 2.00 Nos. 5075.38 4872.36 9744.73 2 Providing And Fixing White Vitreous China Pedestal Type Water Closet (European Type W.C. Pan) With Isi Marked White Solid Plastic Seat And Lid, 10 Litre Low Level White P.V.C. Flushing Cistern With Manually Controlled Device (Handle Lever), Conforming To Is : 7231, With All Fittings And Fixtures Complete Including Cutting And Making Good The Walls And Floors Wherever Required. W.C. Pan With Isi Marked White Solid Plastic Seat And Lid 17.2.1 3.00 Nos. 4886.50 4691.04 14073.11 3 Providing And Fixing Wash Basin With C.I. Brackets, 15 Mm C.P. Brass Pillar Taps, 32 Mm C.P. Brass Waste Of Standard Pattern, Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls Wherever Require A) White Vitreous China Flat Back Wash Basin Size 550X 400 Mm With Single 15 Mm C.P. Brass Pillar Tap. 17.7.4 4.00 Nos. 1409.35 1352.98 5411.91 4 Providing And Fixing White Vitreous China Flat Back Or Wall Corner Type Lipped Front Urinal Basin Of 430X260X350 Mm And 340X410X265 Mm Sizes Respectively With Automatic Flushing Cistern With Standard Flush Pipe And C.P. Brass Spreaders With Brass Unions And G.I Clamps Complete, Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls And Floors Wherever Required A) One Urinal Basin With 5 Litre White P.V.C. Automatic Flushing Cistern 17.4.1 3.00 Nos. 4918.90 4722.14 14166.42 5 Providing And Fixing Flexible P.V.C. Waste Pipe For Sink Or Wash Basin Including Pvc Waste Fittings Complete. Flexible Pipe 17.28.2 A) 32Mm Dia 17.28.2.1 4.00 Nos. 89.66 86.07 344.29 B) 40Mm Dia 17.28.2.2 2.00 Nos. 89.66 86.07 172.15 6 Providing And Fixing 600X450 Mm Beveled Edge Mirror Of Superior Glass (Of Approved Quality) Complete With 6 Mm Thick Hard Board Ground Fixed To Wooden Cleats With C.P. Brass Screws And Washers Complete. 17.31 4.00 No. 1205.92 1157.69 4630.74 7 Providing And Fixing Cp Brass Single Lever Lelephonic Wall Mixture Of Quality & Make And As Per Thedirection Of Enginer-Incharge. A) 15Mm Dia Nominal Dia. 17.22B 2.00 Each 5205.39 4997.17 9994.34 8 Providing And Fixing 8 Mm Dia C.P./S.S. Jet With Flexible Tube Upto 1 Meter Long With S.S. Triangular Plate For Eureopean Type W.C. Of Quality And Make As Approved By Engineer-In-Charge. 15Mm Nominal Bore 17.16A 2.00 Each 261.85 251.38 502.76 Sanitary Fixtures & Accessories : I 9 Providing And Fixing Ptmt Towel Rail Complete With Brackets Fixed To Wooden Cleats With Cp Brass Screws With Concealed Fittings Arrangement Of Approved Quality And Colour. 600 Mm Long Towel Rail With Total Length Of 645 Mm, Width 78 Mm And Effective Height Of 88 Mm, Weighing Not Less Than 190 Gms. Dsr-17.73.2 1.00 Each 531.69 510.43 510.43 10 Providing And Fixing Ptmt Soap Dish Holder Having Length Of 138Mm, Breadth 102Mm, Height Of 75Mm With Concealed Fitting Arrangements, Weighing Not Less Than 106 Gms. Dsr-18.65 1.00 Each 83.58 80.24 80.24 11 Providing And Fixing C.P. Brass Ablution Health Faucet Assembly With 1.0 M Long Braided Pvc Hose With Mounting Bracket Fixed On Wall Complete.[For Ewc]-Make-Jaquar Ald565 Mr 2.00 Each 1705.00 1636.80 3273.60 12 Providing And Fixing C.P. Brass Two-Way Angle Valve For Ewc Points & For Fixing Ablution Health Faucet Of Approved Quality Conforming To Is:8931. 15 Mm Nominal Bore-Essco Sqt 526A Mr 2.00 Each 1335.00 1281.60 2563.20 1 Providing And Fixing On Wall Face Unplasticised Rigid Pvc Rain Water Pipes Conforming To Is : 13592 Type A Including Jointing With Seal Ring Conforming To Is : 5382 Leaving 10 Mm Gap For Thermal Expansion . (I) Single Socketed Pipes. A) 110Mm Diameter 12.41.2 31.30 Mtr 283.04 271.72 8504.80 2 Making Khurras 45X45 Cm With Average Minimum Thickness Of 5 Cm Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate Of 20 Mm Nominal Size) Over Pvc Sheet 1M X 1 M X 400 Micron, Finished With 12 Mm Cement Plaster 1:3 (1 Cement : 3 Coarse Sand) And A Coat Of Neat Cement,Punning,Rounding The Edges And Making And Finishing The Outlet Complete. A) 110Mm 12.22 7.00 Nos. 223.68 214.73 1503.13 3 Providing And Fixing Unplasticised -Pvc Pipe Clips Of Approved Design To Unplasticised - Pvc Rain Water Pipes By Means Of 50X50X50Mm Hard Wood Plugs, Screwed With M.S. Screws Of Required Length Including Cutting Brick Work And Fixing In Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) And Making Good The Wall Etc. Complete. A) 110Mm 12.43.2 20.00 Nos. 278.47 267.33 5346.54 4 Providing And Fixing On Wall Face Unplasticised Rigid Pvc Rain Water Pipes Conforming To Is : 13592 Type A, Including Jointing With Seal Ring Conforming To Is : 5382, Leaving 10 Mm Gap For Thermal Expansion, (I)Single Socketed Pipes. 110 Mm Diameter 12.41.2 Rm. 283.04 271.72 5 Providing And Fixing To The Inlet Mouth Of Rain Water Pipe Cast Iron Grating 15 Cm Diameter And Weighing Not Less Than 440 Grams. Dsr-12.44 8.00 Nos. 41.02 39.38 315.06 6 Providing And Fixing In Floor And Wall Face Ringfit Upvc Astral Ultradrain Conventional System For Soil And Waste Water Pipes Conforming To (Hsn Code: 3917) Type B Including Jointing With Seal Ring. (I) Double Socketed Pipes. A) 110Mm Dia P.V.C. Pipe Nsr 20.00 Rm. 485.00 465.60 9312.00 B) 90Mm Dia P.V.C. Pipe Nsr 25.00 Rm. 390.00 374.40 9360.00 6 Providing & Fixing Upvc Floor Trap Of Self Cleansing Design With Cp Jali Complete In All Respects. (Make : Supreme / Finolex / Prince) P-Trap Type Floor Trap 110 X 90 Mm Nsr 12.00 No. 195.00 187.20 2246.40 7 Providing And Fixing On Wall Face Unplasticised - Pvc Moulded Fittings/Accessories For Unplasticised Rigid Pvc Pipes Including Jointing With Seal Ring Leaving 10 Mm Gap For Thermal Expansion.. (Make : Supreme / Finolex / Prince) Door Tee 110X110X110 Mm Nsr 2.00 No. 280.00 268.80 537.60 110X110X90 Mm Nsr 2.00 No. 200.00 192.00 384.00 Bend 110 Mm Nsr 2.00 No. 170.00 163.20 326.40 Soil Waste & Vent Pipes And Fittings - Ii 90 Mm Nsr 2.00 No. 160.00 153.60 307.20 1 Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineer In Charge.Lls Etc. (Internal Work) I) Exposed On Wall A) 32Mm Nominal Dia Pipe 18.9.4 30.00 Rm. 328.94 315.78 9473.44 3 Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings Including Fixing The Pipe With Clamps At 1.00M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer In Charge. (Internal Work) I) Exposed On Wall A) 25Mm Dia Nominal Outer Dia Pipes 18.7.3 20.00 Rm. 301.15 289.11 5782.13 4 Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings I/C Fixing The Pipe With Clamps At 1.00M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement And The Cost Of Cutting Chases And Making Good The Same Including Testiang Of Joints Complete As Per Direction Of Engineer In Charge. Concealed Work Including Cutting Chases And Making Good The Walls Etc. A) 15Mm Dia Nominal Outer Dia Pipes 18.8.1 70.00 Rm. 373.34 358.40 25088.28 B) 20Mm Dia Nominal Outer Dia Pipes 18.8.2 20.00 Rm. 403.19 387.06 7741.18 C) 25Mm Dia Nominal Outer Dia Pipes 18.8.3 Rm. 470.42 451.60 5 Providing & Fixing G.I. Pipes Complete With G.I. Fittings & Clamps Including Cutting & Making Good The Walls Etc. (Internal Work) I) Exposed On Wall A) 25Mm Dia Nominal Bore (Medium Duty) Dsr-18.10.3 20.00 Rm. 413.76 397.21 7944.21 Ii) Concealed Pipe Including Painting With Anticorrosive Bitumatic Paint, Cutting Chases And Making Good The Wall. A) 15Mm Dia Nominal Bore Dsr-18.11.1 15.00 Rm. 435.32 417.91 6268.65 2 Painting G.I. Pipes And Fittings With Synthetic Enamel White Paint Over A Ready Mixed Priming Coat, Both Of Approved Quality For New Work. A) 15Mm Dia Nominal Bore. Dsr-18.38.1 15.00 Rm. 14.55 13.97 209.51 B) 25Mm Dia Nominal Bore. Dsr-18.38.3 10.00 Rm. 22.69 21.78 217.79 2 Providing And Fixing 45 Cm Long Unplasticised Pvc Connection Pipe With Brass Unions. A) 15Mm Nominal Bore Dsr18.21.2.1 4.00 Nos. 73.31 70.38 281.51 5 Providing & Fixing Cp Brass Bib Cock Of Approved Quality Conforming To Is 8931 A) 15Mm Nominal Bore 18.49.1 7.00 Nos. 380.09 364.88 2554.19 6 Providing & Fixing C.P. Brass Long Body Bib Cock Of Approved Quality Conforming To Is Standards And Weighing Not Less Than 690 Gms. A) 15Mm Nominal Bore 18.51.1 7.00 Nos. 599.19 575.22 4026.57 7 Providing & Fixing C.P. Brass Angle Valve For Basin Mixer And Gyser Points Of Approved Quality Conforming To Is 8931 A) 15Mm Nominal Bore 18.53.1 14.00 Nos. 430.71 413.48 5788.75 8 Providing And Fixing Gun Metal Gate Valve With Wheel Of Approved Quality. A) 25Mm Dia Nominal Bore 18.17.1 2.00 Each 466.78 448.11 896.23 B) 32Mm Dia Nominal Bore 18.17.2 1.00 Each 517.18 496.50 496.50 C) 50Mm Dia Nominal Bore 18.17.4 Each 769.96 739.16 Water Supply Pipes And Fittings - Iii 9 Providing And Fixing Ball Valve (Brass) Of Approved Quality, High Or Low Pressure, With Plastic Floats Complete 20Mm Dia Nominal Bore 18.18.2 1.00 Each 346.86 332.99 332.99 A) 25 Mm Nominal Bore 18.18.3 2.00 Nos. 348.03 334.10 668.21 10 Providing And Placing On Terrace (At All Floor Levels) Polyethylene Water Storage Tank Of Approved Brand And Manufacture With Cover And Suitable Locking Arrangement And Making Necessary Holes For Inlet, Outlet And Overflow Pipes But Without Fittings And The Base Support For Tank. 18.48 A) Circular Tank 18.48 2500.00 Ltrs 8.25 7.92 19799.33 11 Providing And Fixing Stone Slab Table Rubbed, Edges Rounded And Polished Of Size 75X50Cm Deep And 1.8Cm Thick Fixed In Urinal Partitions By Cutting A Chase Of Appropriate Width With Chase Cutter And Embedding The Stone In The Chase With Epoxy Grout Or With Cement Concrete 1:2:4 (1Cement: 2Coarse Sand: 4Graded Stone Aggregate 6Mm Nominal Size) As Per Direction Of Engineerin-Charge And Finished Smooth. 8.10 Granite Stone Of Approved Shade Dsr-8.10.2 1.08 Sqm. 3038.79 2917.23 3150.61 1 Providing & Fixing Soil, Waste And Vent Pipes. A) 100Mm Dia Centrifugally Cast Iron S & S Pipe. Dsr17.35.1.2 6.00 Rm. 885.53 850.11 5100.67 2 Providing Lead Caulked Joints To Sand Cast Iron/Centrifugally Cast (Spun) Iron Pipes & Fitting Of Diameters. A) 100Mm Dsr-17.58.1 2.00 Each 466.86 448.18 896.37 3 Providing & Fixing M.S. Holder Bat Clamps Of Approved Design To Sand Cast Iron/Centrifugally Cast (Spun) Iron S & S Pipe Embeded In & Including Cement Concrete Blocks 10X10X10Cm. Of 1:2:4 Mix (1 Cement : 2 Coarse : 4 Graded Stone Aggregate 20Mm Nominal Size). Including Cost Of Cutting Holes & Making Good The Walls Etc. A) For 100Mm Dia Pipe. Dsr-17.37.1 2.00 Each 272.13 261.24 522.49 4 Providing & Fixing Cast Iron Trap Of Self Cleansing Design With Or Without Ventarm Complete, Including Cost Of Cutting & Making Good The Walls & Floors. A) 100Mm Inlet & 75Mm Outlet. Dsr17.60.2.1 1.00 No. 1481.31 1422.06 1422.06 5 Providing & Fixing Cast Iron Coller. A) 100Mm Dia. Dsr17.57.1.2 2.00 No. 384.85 369.46 738.91 6 Providing And Fixing Plain Cast Iron S & S Sanitary Bend. A) 100Mm Dsr17.39.1.2 2.00 Nos. 427.52 410.42 820.84 1 Providing And Fixing In Floor And Wall Face Ringfit Upvc Astral Ultradrain Conventional System For Soil And Waste Water Pipes Conforming To (Hsn Code: 3917) Type B Including Jointing With Seal Ring. (I) Double Socketed Pipes. A) 110Mm Dia P.V.C. Pipe Mr 7.50 M 485.00 465.60 3492.00 2 Providing And Fixing Square Mouth S.W. Gully Trap Grade A Complete With C.I. Grating Brick Masonry Chamber With F.P.S. Bricks Of Class Designation 75 And Water Tight C.I. Cover With Frame Of 300 X 300Mm. Size (Inside) The Weight Of Cover To Be Not Less Than 4.50 Kg And Frame To Be Not Less Than 2.70 Kg As Per Standard Design. A) 150 X 100 Mm. Size P Type With Sewer Bricks Conforming To Is : 4885 Dsr-19.4.2.1 1.00 Nos 2050.58 1968.56 1968.56 Soil Waste & Vent Pipes And Fittings - Ii Schedule Of Quantities For Internal Sewerage System - Iv 3 Constructing Brick Masonry Manhole In Cement Mortar 1:4 (1 Cement :4 Coarse Sand) Rcc Top Slab With 1:2:4 Mix (1 Cement :2 Coarse Sand :4 Graded Stone Aggregate 20Mm Nominal Size), Foundation Concrete 1:4:8 Mix (1 Cement :4 Coarse Sand :8 Graded Stone Aggregate 40Mm Nominal Size) Inside Plastering 12Mm Thick With Cement Mortar 1:3 (1 Cement :3 Coarse Sand) Finished With Floating Coat Fo Neat Cement And Making Channels In Cement Concrete 1:2:4 (1 Cement :2 Coarse Sand :4 Graded Stone Aggregate 20Mm Nminal Size) Finished With A Floating Coat Of Neat Cement Complete As Per Standard Design 19.7 Inside Size 90X80Cms And 45Cms Deep Including Ci Cover With Frame (Light Duty) 455X610Mm Internal Diamensions Total Weight Of Cover And Frame To Be Not Less Than 38 Kg (Weight Of Cover 23 Kg And Weight Of Frame 15Kg). 19.7.1 With Fps Bricks Of Class Designation 150 Dsr-19.7.1.1 1.00 Each 9577.59 9194.49 9194.49 External Sewerage Works 1 Excavating Trenches In All Kind Of Soil Of Required Width For Pipes. Including Excavation For Sockets And Dressing Of Sides, Ramming Of Bottoms, Including Getting Out The Excavated Soil & Then Returning The Soil As Required, In Layers Not Exceeding 20 Cm In Depth Including Consolidating Each Deposited Layer By Ramming, Watering, Etc & Disposing Of Surplus Excavated Soil As Directed Within A Lead Of 50M. Up To 1.50 M Depth Pipes 80 Mm To 300 Mm Diameter 2.10.1.2 20.00 Rm 264.10 253.54 5070.79 2 Providing And Fixing In Floor And Wall Face Ringfit Upvc Astral Ultradrain Conventional System For Soil And Waste Water Pipes Conforming To (Hsn Code: 3917) Type B Including Jointing With Seal Ring. (I) Double Socketed Pipes. 160Mm Dia Under Floor (For External Sewer) Nsr 20.00 Metre 1190.00 1142.40 22848.00 3 Constructing Brick Masonry Manhole With F.P.S. Bricks In Cement Mortar 1 : 4 (1 Cement : 4 Coarse Sand) Rcc Top Slab With 1 : 2 : 4 Mix (1 Cement : 2 Coarse Sand : 4 Grade Stone Aggregate 20Mm Nominal Size); Foundation Concrete 1:4:8 Mix (1 Cement : 4 Coarse Sand : 8 Graded Stone Aggregate 40 Mm Nominal Size) Inside Plastering 12 Mm Thick With Cement Mortar 1:3 (1Cement 3 Coarse Sand) Finished With A Floating Coat Of Neat Cement And Making Channels In Cement Concrete 1:2:4 (1Cement : 2 Coarse Sand: 4 Graded Stone Aggregate 20 Mm Nominal Size) Finishd With A Floating Coat Of Neat Cement Complete As Per Standard Design Inside Size 90 X 80 Cm & 45 Cm Deep Including Ci Cover With Frame (Light Duty) 455 X 610 Mm Internal Dimension Total Wt. Of Cover & Frame To Be Not Less Than 38 Kg (Wt. Of Cover 23 Kg And Wt. Of Frame 15 Kg) 19.7.1.1 3.00 Nos 9577.59 9194.49 27583.46 4 Extra For Depth For Manhole With F.P.S. Bricks Size 90 X 80 Cm 19.8.1.1 0.30 Rm 6618.83 6354.07 1906.22 5 Providing M.S. Foot Rests Including Fixing In Manholes With 20*20*10 Cm Cement Concrete Blocks 1:3:6 (1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20 Mm Nominal Size) As Per Standard Design : With 20 X 20 Mm Square Bar 19.15.1 3.00 Nos 408.51 392.17 1176.51 6 Providing And Fixing Square Mouth S.W. Gully Trap Grade `A Complete With C.I. Grating Brick Masonry Chamber With F.P.S Bricks And Water Tight Ci Cover With Frame Of 300 X 300 Mm Size (Inside) The Weight Of Cover To Be Not Less Than 4.50 Kg And Frame To Be Not Less Than 2.70 Kg As Per Standard Design 180 X 150 Mm. Size P Type 19.4.3.1 2.00 Nos 2101.54 2017.48 4034.96 7 Making Soak Pit 2.5 M Diameter 3.0 Metre Deep With 45 X 45 Cm Dry Brick Honey Comb Shaft With Bricks And S.W. Drain Pipe 100 Mm Diameter, 1.8 M Long Complete As Per Standard Design. With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 19.32.1 1.00 Nos 20145.75 19339.92 19339.92 8 Providing M.S. Foot Rests Including Fixing In Manholes With 20X20X10 Cm Cement Concrete Blocks 1:3:6 (1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20 Mm Nominal Size) As Per Standard Design With 20X20 Mm Square Bar Dsr-19.15.1 8.00 Nos. 408.51 392.17 3137.37 9 Providing And Fixing S.C.I. Tee 150 Mm At The Inlet And Outlet Of Septic Tank. Dsr-7087 2.00 Nos. 621.00 596.16 1192.32 10 Providing And Fixing Soil, Waste And Vent Pipes:75 Mm Diameter Sand Cast Iron S&S Pipe As Per Is: 1729 Dsr17.35.2.1 3.00 Rmt. 783.54 752.19 2256.58 11 Providing & Fixing Of 75Mm Dia Sand Cast Iron S&S As Per Is - 1729 Terminal Guard. Dsr17.56.2.1 2.00 Nos. 255.52 245.30 490.59 12 Providing & Fixing 75Mm Plane Sand Cast Iron S&S Bend Of Required Drgtee. Dsr17.39.2.1 2.00 Nos. 282.18 270.89 541.78 13 Providing Lead Caulked Joints To Sand Cast Iron/ Cetrifugally Cast (Squn) Irons Pipes & Fitting Of 50 Mm Dia Dsr-17.58.2 2.00 Nos. 394.67 378.89 757.77 14 Providing And Fixing In Position Precast Rcc Manhole Cover And Frame Of Required Shape And Approved Quality.M.D. -10- Circular Shape 500Mm Internal Diameter Dsr19.19.2.2 2.00 Nos. 879.42 844.24 1688.49 1 Wiring For Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq.Mm Frls/Hffr Pvc Insulated Copper Conductor Single Core Cable In Surface/ Recessed Medium Class Pvc Conduit, With Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm Frls/Hffr Pvc Insulated Copper Conductor Single Core Cable Etc. As Required Dsr 1.10.3 51.00 Each 1115.37 1070.76 54608.68 2 Wiring For Twin Control Light Point With 1.5 Sq.Mm Frls/Hffr Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Medium Class Pvc Conduit, 2Way Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm Frls/Hffr Pvc Insulated Copper Conductor Single Core Cable Etc. As Required Dsr 1.11 4.00 Each 1187.60 1140.10 4560.39 3 Supplying And Fixing Of Following Sizes Of Medium Class Pvc Conduit Along With Accessories In Surface/Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. Dsr 1.21.1 17.00 Metre 97.32 93.43 1588.26 4 Wiring For Circuit/ Submain Wiring Along With Earth Wire With The Following Sizes Of Frls/Hffr Pvc Insulated Copper Conductor, Single Core Cable In Surface/ Recessed Medium Class Pvc Conduit As Required.2 X 1.5 Sq. Mm + 1 X 1.5 Sq. Mm Earth Wire Dsr 1.14.1 650.00 Metre 177.15 170.07 110542.86 5 Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface/ Recessed Medium Class Pvc Conduit As Required 2 X 2.5 Sq. Mm + 1 X 2.5 Sq. Mm Earth Wire Dsr 1.14.2 188.00 Metre 285.12 273.71 51457.72 6 Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface/ Recessed Medium Class Pvc Conduit As Required 2 X 4 Sq. Mm + 1 X 4 Sq. Mm Earth Wire Dsr 1.14.3 202.00 Metre 253.94 243.79 49244.67 7 Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface/ Recessed Medium Class Pvc Conduit As Required 2 X 6 Sq. Mm + 1 X 6 Sq. Mm Earth Wire Dsr 1.14.4 105.00 Metre 333.78 320.42 33644.59 8 Supplying And Fixing Suitable Size Gi Box With Modular Plate And Cover In Front On Surface Or In Recess, Including Providing And Fixing 6 Pin 5/6 & 15/16 A Modular Socket Outlet And 15/16 A Modular Switch, Connections Etc. As Required Dsr 1.32 22.00 Each 445.54 427.72 9409.83 9 Supplying And Fixing Brass Batten/ Angle Holder Including Connection Etc. As Required Dsr 1.34 15.00 Each 99.60 95.62 1434.25 Electrical Works 10 Installation ,Testing, Commissioning Of Wall Bracket /Ceiling Fittings Of All Sizes And Shapes Containing Upto Two Ls/Cfl/Led Lamps Per Fitting, Complete With All Accessories Including Connections Etc. As Required. Dsr 1.35 1.00 Each 90.48 86.86 86.86 11 Supplying, Installation, Testing & Commissioning Of Led Recessed/ Surface Down Lighter (Round/ Square/ Rectangular) Smd Type Of Following Body Material With Pmma And Prismatic Diffuser And Construction As Per Is : 10322 With Driver As Per The Requirement With Driver Efficiency >85%, Operating Voltage Ac 140-270 Volt, Frequency 50/60 Hz, Operating Temp Range -50C To 400C, Internal Surge Protection Of 2.5 Kv With Short & Open Circuit Protection ,Thd < 10% , P. F.≥0.95, Ip20, Cri >80, Ugr (Unified Glare Rating) < 19, Flicker Free (Flicker Should Be Below 5%), Life Time (Led, Driver & Electrical Circuitry), Of Minimum 50000 Burning Hours With 70% Of Initial Lumen Maintained Till Life Ends, Cct 3000°K /4000°K / 5700°K / 6500°K (As Per Ansi Bin), Sdcm (Standard Deviation Colour Matching) <3, Maximum Power Consumption Should Not More Than The Specified Rating And Fixture Shall Be Confirming To Relevant Bis Standards. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen Printing On Housing Complete In All Respect I/C External Connections With 1.5 Sq.Mm Frls/Hffr, Pvc Insulated Copper Conductor Single Core Cable And Earthing Etc. As Required With Minimum 5 Year Oem Warranty. System Lumen Efficacy ≥105 And <120 Lm/Watt Output . Lm79 & Lm80 Test Report And All Testing Required For Led Fixtures As Per Bis Shall Be Submitted. Shape Size And Cct Shall Be As Approved By Engineer-In-Charge As Per Requirement. (Thermal Management: Heat Sink Of Aluminium Housing Such That Led Junction Temperature Shall Not Rise Above 90°C) Powder Coated Die Cast /Extruded Aluminium Body Including Trim 18 Watt Mr 19.00 Each 700.00 672.00 12768.00 12 Earthing With G.I. Earth Plate 600 Mm X 600 Mm X 6 Mm Thick Including Accessories, And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Of 2.7 Metre Long Etc. With Charcoal/ Coke And Salt As Required Dsr-5.4 3.00 Each 5681.03 5453.79 16361.37 13 Supplying And Laying 25 Mm X 5 Mm G.I Strip At 0.50 Metre Below Ground As Strip Earth Electrode, Including Connection/ Terminating With G.I. Nut, Bolt, Spring, Washer Etc. As Required. (Jointing Shall Be Done By Overlapping And With 2 Sets Of G.I. Nut Bolt & Spring Washer Spaced At 50Mm) Dsr 5.9 55.00 Metre 109.48 105.11 5780.78 14 Supplying And Fixing 5 A To 32 A Rating, 240/415 V, 10 Ka, C Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. A) Single Pole Dsr-2.10.1 9.00 Each 194.64 186.85 1681.68 15 Supplying And Fixing Following Way, Single Pole And Neutral, Sheet Steel, Mcb Distribution Board, 240 V, On Surface/ Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Including Earthing Etc. As Required. (But Without Mcb/Rccb/Isolator) A) 6 Way (4 + 12), Double Door Dsr-2.3.1 2.00 Each 1677.24 1610.15 3220.30 16 Supplying And Fixing Following Way, Horizontal Type Three Pole And Neutral, Sheet Steel, Mcb Distribution Board, 415 V, On Surface/ Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Including Earthing Etc. As Required. (But Without Mcb/Rccb/Isolator) A) 4 Way (4 + 12), Double Door Dsr-2.4.1 1.00 Each 3110.42 2986.01 2986.01 17 Supplying And Fixing 5 A To 32 A Rating, 240/415 V, 10 Ka, C Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. Dsr-2.10.3 2.00 Each 498.76 478.81 957.62 16 Installation, Testing And Commissioning Of Ceiling Fan, Including Wiring The Down Rods Of Standard Length (Upto 30 Cm) With 1.5 Sq. Mm Frls Pvc Insulated, Copper Conductor, Single Core Cable, Including Providing And Fixing Phenolic Laminated Sheet Cover On The Fan Box Etc. As Required Dsr 1.45 10.00 Each 257.74 247.43 2474.35 17 Supplying And Fixing Two Module Stepped Type Electronic Fan Regulator On The Existing Modular Plate Switch Box Including Connections But Excluding Modular Plate Etc. As Required. Dsr 1.25 10.00 Each 280.55 269.33 2693.32 18 Installation Of Exhaust Fan In The Existing Opening, Including Making Good The Damage, Connection, Testing, Commissioning Etc. As Required. Upto 450 Mm Sweep Dsr-1.50.1 7.00 Each 342.14 328.45 2299.17 19 Extra For Fixing The Louvers/ Shutters Complete With Frame For A Exhaust Fan Of All Sizes Dsr-1.51 7.00 Each 157.38 151.09 1057.62 20 Supply, Installation, Testing And Commissioning Of Ceiling Fan With Brush Less Direct Current (Bldc) Motor, Class Of Insulation: B, 3 Nos. Metal( Aluminium Alloy) Blades, 30 Cm Long Down Rod, 2 Nos. Canopies, Shackle Kit, Safety Rope, Copper Winding, Steel/Al Body Power Factor Not Less Than 0.9, Service Value (Cm/M/W) Minimum As Below, 350 Rpm (Tolerance As Per Is : 374-2019), Thd (Total Harmonic Distortion) Less Than 10%, Suitable For Operation With Regulator For Speed Control And All Remaining Accessories Including Safety Pin, Nut Bolts, Washers, Temperature Rise=75 0C (Max.), Insulation Resistance More Than 2 Mega Ohm, Suitable For 230 V, 50 Hz, Single Phase Ac Supply, Ceiling Fan Compliant To Is 374:2019 Fan I/C External Connections With 1.5 Sq.Mm Frls/Hffr, Pvc Insulated Copper Conductor Single Core Cable And Earthing Etc. As Required. 9.2.3 10.00 Each 2075.64 1992.62 19926.18 21 Supplying And Laying Of Aluminium Conductor Pvc Insulated Armoured Served Sheathed Cable 1100 Volts Grade At The Depth Of 750 Mm Bellow Ground Level Over A Cushion Of 75 Mm Thick Sand All Around And Protected With Burnt Bricks On Side And On Top .On Surface The Cable Run Shall Be Fixed On Ms Clamps Etc.Of Suitable Size Or As Directed By The Engineer-Incharge ,Complete In All Respect.The Armouring Of The Cable Shall Be Properly Connected With The Earth Conductor By Clamps Etc. Following Size 10 Sqmm X 2 Core Mr 164.00 Rm 410.34 393.93 64603.77 22 Supply & Fixing Of 225/230Mm Sweep Ventilating (Light Duty) Exhaust Fan Complete With Metallic Blade (Steel Bird Guard Protector /Copper Motor For High Air Suction Performance /Capacitor Etc.), Noise Level : (45 - 50) Db, Power Consumption : 45 W, Rated Voltage : 230 V, Rated Frequency : 50 Hz, Motor Type : Normal Speed. Complete In All Respect. Mr 7.00 Each 1665.00 1598.40 11188.80 23 Cost For Murals Work 32.40 Sqm 5850.00 5616.00 181958.40 24 Cost For Solar Street Light With 7M Pole Complete 15.00 Nos 22600.00 21696.00 325440.00 25 Cost For C.C. Bench 12.00 Nos 10000.00 9600.00 115200.00 26 Cost For Dustbin 6.00 Nos 4500.00 4320.00 25920.00 1. Trenching In Ordinary Soil Up To A Depth Of 60 Cm Including Removal And Stacking Of Serviceable Materials And Then Disposing Of Surplus Soil, By Spreading And Neatly Levelling Within A Lead Of 50 M And Making Up The Trenched Area To Proper Levels By Filling With Earth Or Earth Mixed With Sludge Or / And Manure Before And After Flooding Trench With Water (Excluding Cost Of Imported Earth, Sludge Or Manure).. (Horti) 2.1 159.24 Cum 74.51 71.53 11389.98 2 Supplying And Stacking Of Good Earth At Site Including Royalty And Carriage Upto 5 Km Lead Complete (Earth Measured In Stacks Will Be Reduced By 20% For Payment). (Horti) 2.2 79.62 Cum 491.88 472.21 37597.13 Horticulture 3 Supplying And Stacking At Site Dump Manure From Approved Source, Including Carriage Upto 5 Km Lead Complete (Manure Measured In Stacks Will Be Reduced By 8% For Payment) : Screened Through Sieve Of I.S. Designation 20 Mm (Horti) 2.4.1 106.16 Cum 242.46 232.76 24709.88 4 Spreading Of Sludge, Dump Manure And / Or Good Earth In Required Thickness As Per Direction Of Officer-In-Charge (Cost Of Sludge, Dump Manure And / Or Good Earth To Be Paid Separately). (Horti) 2.8 159.24 Cum 49.94 47.94 7634.64 5 Mixing Earth And Sludge Or Manure In The Required Proportion Specified Or Directed By The Officer-In-Charge (Horti) 2.9 159.24 Cum 34.87 33.47 5330.39 6 Grassing With Selection No.1 Grass Including Watering And Maintenance Of The Lawn For 30 Days Or More Till The Grass Forms A Thick Lawn, Free From Weeds And Fit For Mowing Including Supplying Good Earth, If Needed (The Good Earth Shall Be Paid For Separately). In Rows 5 Cm Apart In Both Directions. (Horti) 2.10.1 530.80 Sqm 16.89 16.21 8604.46 7 Providing And Displaying Of Aglaonema Silver Queen Having 30 Cm To 45 Cm. Ht. With 12 To 15 Leaves, Multi Suckers, Fresh And Healthy Leaves, Well Developed In 25 Cm Dia Earthen Pot/Plastic Pot & As Per Direction Of The Officer-In-Charge. (Horti) 3.8 60.00 Each 154.50 148.32 8899.22 (Horti) Dsr 3.8 8 Providing And Displaying Of Aglaonema Dove Variety Having Ht. 30 Cm To 45 Cm With 8 To 10 Leaves, Well Developed, Fresh And Healthy In 25 Cm Size Of Earthen Pot/Plastic Pot & As Per Direction Of The Officer-In-Charge. (Horti) 3.4 75.00 Each 77.42 74.32 5574.03 (Horti) Dsr 3.4 9 Providing And Displaying Of Aglaonema Marentifolium Variety Having Ht. 23 Cm To 30 Cm With 8 To 10 Leaves, Well Developed, Fresh And Healthy With Colorful Leaves In 20 Cm Size Of Earthen Pot/Plastic Pot. & As Per Direction Of The Officer-In-Charge. (Horti) 3.10 50.00 Each 64.54 61.96 3097.83 (Horti) Dsr 3.10 10 Providing And Displaying Of Chamaedorea Elegans Palm Having Ht. 60 Cm To 75 Cm, Well Developed With Fresh And Healthy Leaves In 25 Cm Size Of Earthen Pot/Plastic Pot. & As Per Direction Of The Officer-In-Charge. (Horti) 3.26 50.00 Each 102.70 98.59 4929.51 (Horti) Dsr 3.26 11 Providing And Displaying Of Croton Baby Golden Variety Having Ht.30 Cm And Above, Well Developed With Full Of Fresh And Healthy Leaves In 20 Cm Size Of Earthen Pot/Plastic Pot & As Per Direction Of The Officer-In-Charge. (Horti) 3.28 150.00 Each 39.11 37.55 5632.42 (Horti) Dsr 3.28 12 Providing And Displaying Of Croton Golden (Broad Leaves) Having Ht. 60 Cm To 75 Cm With 3 To 4 Branches, Well Developed, Fresh And Healthy Leaves In 25 Cm Size Of Earthen Pot/Plastic Pot. & As Per Direction Of The Officer-In-Charge. (Horti) 3.32 150.00 Each 53.81 51.65 7748.01 (Horti) Dsr 3.32 13 Providing And Displaying Of Dieffenbachia Tropic-Snow Having Ht. 60 Cm & Above With 8 - 10 Leaves, Well Developed, Fresh & Healthy In 25 Cm Size Of Earthen Pot/Plastic Pot & As Per Direction Of The Officer-In-Charge. (Horti) 3.40 50.00 Each 75.32 72.31 3615.28 (Horti) Dsr 3.40 14 Providing And Displaying Of Dieffenbachia Mosaic Having Ht. 30Cm To 45 Cm With 10-12 Leaves, Well Developed, Fresh And Healthy In 25 Cm Size Of Earthen Pot/Plastic Pot. & As Per Direction Of The Officer-In-Charge. (Horti) 3.41 50.00 Each 75.32 72.31 3615.28 (Horti) Dsr 3.41 15 Providing And Displaying Dianthus In Different Colour Well Developed With Fresh & Healthy Foliage 30 Cm Ht., In Full Bloom With Stacking In 25 Cm Earthen Pot/Plastic Pot And As Per Direction Of The Officer-In-Charge. (Horti) 4.29 50.00 Each 51.79 49.72 2486.05 (Horti) Dsr 4.29 16 Providing And Displaying Gazania Hybrid In Different Colour Well Developed With Fresh & Healthy Foliage With Full Bloom In 25 Cm Earthen Pot/Plastic Pot And As Per Direction Of The Officer-Incharge. (Horti) 4.31 150.00 Each 61.63 59.16 8874.49 (Horti) Dsr 4.31 17 Providing And Displaying Gaillardia Double Hybrid Variety Well Developed 30 To 45 Cm Ht 20 To 30 Fresh & Healthy Flower With Green Painted Bamboo Stick In 25 Cm Earthen Pot/Plastic Pot And As Per Direction Of The Officer-In-Charge. (Horti) 4.75 120.00 Each 51.85 49.78 5973.11 (Horti) Dsr 4.75 18 Providing And Stacking Of Plant Mogra Of Height 25 To 30 Cm., 2 To 3 Branch In Earthen Pots Of Size 20 Cm Earthen Pot/Plastic Pot And As Per Direction Of The Officer-In-Charge. (Horti) 4.88 100.00 Each 44.03 42.27 4226.60 (Horti) Dsr 4.88 19 Providing And Stacking Of Plant Canna Dwarf Of Height 25 To 30 Cm., 2 To 3 Suckers In Earthen Pots Of Size 20 Cm Earthen Pot/Plastic Pot And As Per Direction Of The Officer-In-Charge. (Horti) 4.89 100.00 Each 34.25 32.88 3287.87 (Horti) Dsr 4.89 20 Bush Rose In Different Colour 2 To 3 Healthy Branch 30 Cm And Above Ht. Well Developed With 8 Or More Flowers / Flower Buds In 20 Cm Earthen Pot /Plastic Pot As Per Direction Of The Officer-Incharge. (Horti) 4.90 100.00 Each 24.47 23.49 2349.13 (Horti) Dsr 4.90 21 Providing And Displaying Budded Rose (H.T. Variety) 3 To 4 Healthy Branch 30 Cm And Above Ht. Well Developed With One And Above Flower Plant In 20 Cm Earthen Pot, As Per Direction Of The Officer-In-Charge. (Horti) 4.91 100.00 Each 31.29 30.04 3003.96 (Horti) Dsr 4.91 22 Providing And Displaying Standard Rose (H.T. Variety) 3 To 4 Healthy Branch 90 Cm And Above Ht. Well Developed With One And Above Flowers In 25 Cm Earthen Pot, As Per Direction Of The Officer-In-Charge. (Horti) 4.93 75.00 Each 143.77 138.02 10351.28 (Horti) Dsr 4.93 23 Providing And Stacking Of Plumeria Rubra Of Height 120-150 Cm. With 3-4 Branches And Thick Stem In Big Size Hdpe Bags As Per Direction Of The Officer-In-Charge. (Horti) 7.72 75.00 Each 381.60 366.34 27475.20 (Horti) Dsr 7.72 24 Providing And Stacking Of Polyalthia Longifolia (Ashok) Of Height 180-195 Cm. In Gunny Bag Of Size 30 Cm As Per Direction Of The Officer-Incharge. (Horti) 7.75 75.00 Each 95.40 91.58 6868.80 (Horti) Dsr 7.75 25 Providing And Stacking Of Saraca Indica (Sita Ashok) Of Height 105-120 Cm. In Big Poly Bags Of Size 25 Cm As Per Direction Of The Officer-In-Charge. (Horti) 7.80 75.00 Each 76.32 73.27 5495.04 (Horti) Dsr 7.80 26 Providing And Stacking Of Terminalia Arjuna Of Height 150-165 Cm. In Big Polybags Of Size 25 Cm As Per Direction Of The Officerin-Charge. (Horti) 7.88 75.00 Each 57.24 54.95 4121.28 (Horti) Dsr 7.88 27 Providing And Stacking Of Calliandra, Emarginata Of Height 45-60 Cm. In Earthen Pot Of Size 20 Cm As Per Direction Of The Officer-Incharge. (Horti) 8.5 150.00 Each 33.39 32.05 4808.16 (Horti) Dsr 8.5 28 Providing And Stacking Of Nerium Oleander (Kaner) Of Height 60- 75 Cm. With 5-6 Branches In Poly Bags Of Size 25 Cm As Per Direction Of The Officer-In-Charge.

Key Dates

Publish Date 08-06-2026
Last Date of Bid Submission 15-06-2026
Tender Opening Date 15-06-2026

Contact Information

Company Name Uttar Pradesh Tourism Development Corporation
Contact Person Managing Dirctor
Address 3rd Floor UPSTDC Ltd Gomti Nagar Lucknow

BOQ Items

Name of Work:- Tourism development work of Shri Ramjanaki Temple, Kotawari in Shahjahanpur district.
Sl. No. Item Description
1As Per Boq Please Enable Macros to View BoQ information

Other Detail

Information Source https://etender.up.nic.in
Download FileName File Description File Size
Download BOQ_2170588.xls Tender Documents 0 KB
Download tenderdocum.pdf Tender Documents 0 KB
Download Tendernotice_1 (19).pdf Tender Documents 0 KB
Download 796a6919-3884-4ce7-b6ac-091d2b0d4aff.html Tender Documents 0 KB
Download boqpdff.pdf Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.