| 1 | Supply, installation, testing and commissioning of 1.5 TR capacity Window Air Conditioner unit electric driven having digital inverter rotary type compressor (single phase), 220 Volts - 240 Volts, 50 Hz, 5 Star rating and EER 3.2 with cordless remote control, complete all as speciifed and directed. |
| 2 | Supply, installation, testing and commissioning of Water Cooler, electric driven (single phase) having approximate storage capacity of 80 litre and normal cooling capacity of 40 ltrs per hour, alongwith provision of suitable accessories as required for sucessful working of cooler, complete all as specified and directed. |
| 3 | Supply, installation, testing and commissioning of Water Cooler, electric driven (single phase) having approximate storage capacity of 150 litre and normal cooling capacity of 150 ltrs per hour, alongwith provision of suitable accessories as required for sucessful working of cooler, complete all as specified and directed. |
| 4 | Supply, installation, testing and commissioning of Refrigerator, Double Door of capacity 310 ltrs, BEE 5 star rated, complete all as specified and directed. |
| 5 | M&L for Water Cooler Platform with PCC 1:4:8 using 40mm stone aggregate 0.75 mtr below ground level and 0.15 mtr above ground level with 1.0 mtr x 1.0 mtr x 0.90 mtr bond on circumference of platform to avoid water pilferage finish neatly complete all as speciifed and directed. |
| 6 | M&L for replacement of two single core (sub main) FRLS PVC insulated cable and one single core green PVC insulated copper conductor earth continuity cable 2 x 2.5 Sqmm + 1 x 2.5 Sqmm earth wire is drawn in and including non metallic, medium duty, rigid PVC conduit not less than 20mm dia concealed in wall including all conduit and fixing accessories including cutting chases & making good to disturbed surfaces with cement mortar ratio of 1:4 and colour wash complete all as speciifed and directed.Note : (i) Cost for cutting, chases required shall deemed to be included in quoted unit rate.(ii) Two run of submain wire, one run of earth wire and one run of PVC conduit shall be measured one RM. |
| 7 | Description same all as per item No 6 here-in-before but of cable 2 x 6.0 Sqmm + 1 x 6.0 Sqmm earth wire |
| 8 | S&F in replacement of sheet metal enclosure single pole and neutral enclosure with a two pin and earth plug and socket along with one MCB, Modular type single pole of current rating 25 Amps, 'C' series 240 Volts AC complete all as specified and directed. |
| 9 | S&F in replacement of Switch Piano type, single pole one way 15 Amps 240 Volts capacity flush type complete all as specified and directed. |
| 10 | S&F in replacement of Socket Outlet 2-in-1, 3 pin, 5 and 15 Amps flush type complete all as specified and directed. |
| 11 | S&F in repair sheet metal enclosure for MCB DB double door type, single pole and neutral 4 way 240 Volts with 200 Amps rated bus bar of suitable size plate and common neutral link, epoxy powder coated, factory made complete without MCB and with enclosure blank plates for unused way complete all as specified and directed. |
| 12 | S&F in replacement of MCB Single Pole and neutral, 6 to 32 Amps, 240 Volts, 10 KA breaking capacity, convenient to 'C' Curve complete all as specified and directed. |
| 13 | S&F in replacement of MCB Single Pole, 6 to 32 Amps 240 Volts, 10 KA breaking capacity, convenient to 'B' Curve complete all as specified and directed. |
| 14 | S&F in replacement of Tube medium grade galvanised with all fitting and fixed complete 15mm dia to wall and ceiling or laid in floors complete all as specified and directed. |
| 15 | S&F in replacement of Stop Valve, cast copper aloy screwed down high pressure with crutch or butter fly handle screwed both end for iron pipe or for unions and fixed of 15mm dia, complete all as specified and directed. |
| 16 | S&F in replacement of PVC connection cotton braided with brass union/coupling of length 300mm with rubber washer suitable for 15mm dia pipe for water connection, complete all as specified and directed. |
| 17 | S&F in replacement of low density polyethylene drain pipe of pressure rating 6 Kg/Sqcm for water cooler connection suitable for 40mm dia pipe for water cooler connection, complete all as specified and directed. Please Enable Macros to View BoQ information |
| 18 | S&F in replacement of low density polyethylene drain pipe of pressure rating 6 Kg/Sqcm for water cooler connection suitable for 40mm dia pipe for water cooler connection, complete all as specified and directed. Please Enable Macros to View BoQ information |