| 1 | Taking down chowkhats or frame n exc 1.5 sqm with shutters (without taking off shutters from the frames). |
| 2 | Taking down chowkhats or frame exc 1.5 sqm but n exc 4.00 sqm with shutters (without taking off shutters from the frames). |
| 3 | Taking down Shutters of any description n exc 1 sqm. |
| 4 | Taking down Shutters of any description exc 1 sqm but n exc 2 sqm |
| 5 | Taking down Shutters of any description n exc 1 sqm and refixing in same opening after alteration. |
| 6 | Taking down Shutters of any description exc 1 sqm but n exc 2 sqm and refixing in same opening . |
| 7 | S&F Pressed steel frames 105x60 mm for doors with one or more rebatesincluding necessary fixing lugs, hinges, lock strike plate, etc., complete as specified. |
| 8 | S&F Pressed steel frames 125x60 mm for doors with one or more rebatesincluding necessary fixing lugs, hinges, lock strike plate, etc., complete as specified. |
| 9 | M&L for plain cement concrete type B-0, 1 : 2 : 4 (using 12.5mm crushed stone aggregate) as in coping, filling chowkhat and holdfast complete all as specified. |
| 10 | S & F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing. |
| 11 | M&L for preparation of new steel surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide complete all as specified. |
| 12 | S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing |
| 13 | S&F Factory Made Solid PVC Moulded Door Shutter, 28 to 30mm thick (stiles), 2mm thick Moulded Prelam PVC Sheet on the front face & 2mm prelam PVC Sheet on back face with particle board core supplying & fixing in frame at site as per specification & drawing |
| 14 | S&F 2nd class hardwood 30 mm thick Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats. |
| 15 | M&L 18/19 mm thick Prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work |
| 16 | S & F 100 mm Butt hinges medium weight cold rolled mild steel. |
| 17 | S & F 75 mm Butt hinges extrucded aluminium alloy with galvanised mild stel hinge pin, anodised and fixed, type C-21. |
| 18 | S&F 150 mm long aluminium anodised barrel tower bolt of extruded section complete. |
| 19 | S&F of 150 mm size aluminium handles cast type anodised. |
| 20 | S&F 250mm long Aluminium alloy, anodised, sliding door bolts with hasp and staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extructed section or cast aluminium alloy and fixed. |
| 21 | S & F 3mm thick plain sheet glass ordinary quality & glazing with oil putty n.exc 0.50 Sqm in each pane including hacking out old broken glass. |
| 22 | S&F 4 mm thick figured glass pin headed type with oil putty n exc 0.5 sqm in each pane complete including hacking out old broken glass. |
| 23 | S & F 5.5mm thick plain sheet glass ordinary quality & glazing with oil putty n exc 0.50 Sqm in each pane. |
| 24 | S&F Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples |
| 25 | S&F in repair Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples |
| 26 | Supply and fixing factory made uPVC white colour Three track three panels sliding window with fly proof S.S wire mesh (Two nos. glazed & one no. wire mesh panels) upto 1.50m height made of (big series) frame 116 x 45 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 1.75 sqm) comprising of uPVC multichambered frame, with inbuilt roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, complete all as specified and directed by Engineer-in-Charge. (Glass or wiremesh shall be paid separately)Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. |
| 27 | M&L Framed work such as grills,gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; hold fast, ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to fe.290.Gde-E-165 |
| 28 | Dismantaling floor, hearth or wall tiling, including cement mortar bedding (but not backing) removing serviceable tile to store & rubbish off the premises. |
| 29 | M&L, 15mm thick screed bed or bedding layer of mortar in CM (1:6) for lying floor finishes. |
| 30 | M&L Non - skid joint free coloured Ceramic tiles of any colour/shade 7 to 8 mm thick area of each tile exceeding 0.06sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the tiles . |
| 31 | M&L in repairs 75mm dia of outlet PVC (SWR) floor trap, plain with grating including jointing with solvent cement. |
| 32 | S & F in repair vitreous china wash hand basin,counter sunk white flat back of size 550 mm x 440 mm including brackets and making necessary arrangement for fixing. |
| 33 | S&F 32 mm bore dia of dishcharge pipe Waste coupling of PTMT(half or full threaded) (Minimum weight 32mm- 45gms/40mm-60 gms) |
| 34 | S&F in repair vitreous china pedastal pan water closet, white (excluding flushing cistern and flush pipe) but including connection to trap, and to flushing pipe, anti-syphonage pipe etc complete and making good to floor . |
| 35 | S&F in repair 10ltr capacity PVC low level flushing cistern, white inlet ball valve, float and handle and connection to pipe including bracket . |
| 36 | S&F 450mm long, 15mm dia, PVC connection pipe, with brass unions on both ends. |
| 37 | S&F Plastic water closet seat, maticng colour, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device |
| 38 | S&F in repair Plastic water closet seat, matching colour, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device |
| 39 | S&F in repair CP Health fauset with 1 Meter PVC Tube and hook . |
| 40 | M&L complete removal of existing treatment on walls and applying two coats of oil bound distemper of approved colour and shade over one coat of putty complete. |
| 41 | M&L Vitrified ceramic tiles 10mm thick (square/rectangular) area of each tile not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete over 15mm thick screed bed in CM 1 : 6 complete all as specified. |
| 42 | M&L Vitrified ceramic tiles 10mm thick (square/rectangular) area of each tile not exceeding 0.36 sqm, in vertical sufaces over 10mm thick backing coat in cm 1 : 4 set and jointed in neat cement slurry and pointed in white or coloured cement to match complete. |
| 43 | M&L Non - skid Ceramic jointless tiles of any colour/shade 7 to 8 mm thick area of each tile exceeding 0.18sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the tiles over 15mm thick screed bed in CM 1 : 6 complete all as specified. |
| 44 | M&L Glazed coloured ceramic tiles in vertical surface 350x 250x 7 mm/ 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match over 10mm thick backing coat in cm 1:4 complete all as specified match |
| 45 | Demolition of cement concrete (un-reinforced) in ground floors and paving n.exc 15cm thick (below or above ground level). |
| 46 | 13036M&L 25mm thick Cement concrete type B-1, 1:2:4 (20mm gradedaggregate) as in leveling course. |
| 47 | Demolition of stone slabs and tiles of any description or thickness in floors, aprons |
| 48 | M&L Pre-polished Machine cut kota stone slab flooring 20-25mm thick over 20 mm thick cement screed bed in cm 1:6 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab complete all as specified. |
| 49 | Taking down cement plaster of any description on brick or stone walls etc including racking out joints, hacking for key, scrubbing down with water etc . |
| 50 | M&L for rendering 15 mm thick on fair faces of brick work / Concrete /stone surfaces in cement mortar (1:6) making finished even & smooth without using extra cement . |
| 51 | M&L for rendering 15 mm thick on fair faces of brick work / Concrete /stone surfaces in cement mortar (1:4) making finished even & smooth without using extra cement using WPC (WPC will be measured separately). |
| 52 | Supply only liquid water proofing compound. |
| 53 | M&L for preparation of old painted wooden surfaces of any description not otherwise described over 10 CM width or girth and applying one coat of synthetic enamel paint of approved colour and shade |
| 54 | M&L for preparation of old painted steel or iron surfaces of any description not otherwise described over 10 CM width or girth and applying one coat of synthetic enamel paint of approved colour and shade |
| 55 | M&L for preparation of existing old or new wall/ ceiling surfaces and applying Two or more coats of 100% premium acrylic emulsion paint having VOC less than 50gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterioe paint of required shade with silicon additives @ 1.43 ltr/10sqm over and including priming coat of exterior primer applied @ 0.90 ltr/10sqm . |
| 56 | M&L for preparation of existing old wall/ ceiling surfaces and applying one coat of 100% premium acrylic emulsion paint having VOC less than 50gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterioe paint of required shade with silicon additives @ 1.43 ltr/10sqm over and including priming coat of exterior primer applied @ 0.90 ltr/10sqm . |
| 57 | M&L for preparation of new plastered wall surfaces and applying two coats of cement based paint of approved colour and shade. |
| 58 | M&L for preparation of old plastered wall surfaces and applying one coat of cement based paint of approved colour and shade. |
| 59 | Taking down carefully exising unserviceable copper/aluminium point wiring (light, fan, socket or power), complete (fitting such as switches,ceiling rose, pendent, regulators etc) removing material to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately and making dood disturbed surfaces of wall, floor etc. complete all as specified and as directed. |
| 60 | Taking down of old unserviceable sub main wiring of any type complete all as specified and as directed. |
| 61 | Taking down the existing unserviceable main switch / cut out / DBs of any type / capacity / description as existing at site including necessary making good the disturbed surfaces to match with the existing finishes all as specified. |
| 62 | M & L for Point wiring using approved colour coding as per IS, with multistranded copper conductor 1.5 Sq. mm (nominal area), two single core, PVC insulated and unsheathed frlshH cable 1100 volts grade, ISI-694 marked drawn through in and including heavy duty, PVC casing caping including all accessories etc, heavy duty ISI marked, with mild steel sunken boxes 1.6 mm thick, 60 mm deep with earth dolly duly, covered with hylem sheet cover 3 mm thick, ISI marked suitable for fixing of switches, fan regulators and sockets including PVC insulated multistranded copper conductor 1.5 Sqmm (nominal area) single core frlshH cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed for the following :-(Contractor should make good even distributed wall/surface as before.) |
| 63 | (a) One light point controlled by one, one way switch 5 Amps |
| 64 | (b) One fan point/ exhaust fan point controlled by one, one way switch 5 Amps and regulator |
| 65 | (c) One 3 pin 5 Amps switch socket outlet point controlled by one switch on independent boad. |
| 66 | (d) One bell point controlled by one, bell switch 5 Amps |
| 67 | (e) One 3 point 5 Amps switch socket outlet point controlled by one switch on the same board. |
| 68 | Description all as per Ser item No 62 here in before but using 2.5 sq mm single core copper conductor cable of multistranded flame retardant PVC insulated unsheathed 1100 volts grade for 5/15 amps switch socket cobmination point including necessary running of 2.5 sq mm copper conductor flame retardant PVC wire as earth continuity conductor along with wiring and connecting to the common earth dolly. |
| 69 | M & L for Point wiring using approved colour coding as per IS, with multistranded copper conductor 1.5 Sq. mm (nominal area), two single core, PVC insulated and unsheathed frlshH cable 1100 volts grade, ISI-694 marked drawn through in and including heavy duty, PVC casing caping/conduit including all accessories etc, heavy duty ISI marked, with GI sunken /surface boxes 1.2 mm thick, 60 mm deep with earth dolly duly as per site requirment , covered with modular white cover plate with frame suitable for modular switches, or PVC surface mounted modular box, including PVC insulated multistranded copper conductor 1.5 Sqmm (nominal area) single core frlshH cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed for the following :- (Note- Modular cover plate and base plate of any module with all fittings are included in point wiring.) Contractor should make good even distributed wall/surface as before. |
| 70 | (a) One light point controlled by one, one way switch 5 Amps |
| 71 | (b) One fan point/ exhaust fan point controlled by one, one way switch 5 Amps and regulator |
| 72 | (c) One 3 pin 5 Amps switch socket outlet point controlled by one switch on independent boad. |
| 73 | (d) One bell point controlled by one, bell switch 5 Amps |
| 74 | Description all as per Ser item No 64 here in before but using 2.5 sq mm single core copper conductor cable of multistranded flame retardant PVC insulated unsheathed 1100 volts grade for 5/15 amps switch socket cobmination point including necessary running of 2.5 sq mm copper conductor flame retardant PVC wire as earth continuity conductor along with wiring and connecting to the common eath dolly. |
| 75 | S & F for Bell push modular 6 Amps single module complete all as specified. |
| 76 | Suply and fix for Bell Electric Ding dong type suitable for operation on 230 volt 50 HZ A C supply complete all as specified and as directed |
| 77 | S & F for Ceiling rose, surface Bakelite suitable ISI marked for batten fitting complete all as specified |
| 78 | S & F for Switch piano flush type, single pole, one way, and 6 Amp complete all as specified. |
| 79 | S & F for Socket outlet multipurpose having provision for 3 pin, 6 Amp and 2 pin, 6 Amp, piano flush type complete all as specified. |
| 80 | S&F in replacement of switch socket combinations flush 5 Amp 5 pin competeI ,ISI marked |
| 81 | S&F switch socket combination 2 in 1, 3 pin, 15 amp multipurpose, flush type, all as specified and as directed |
| 82 | S & F for Modular Switch piano flush type, single pole, one way, and 5/6 Amp single module complete all as specified. |
| 83 | S & F for Modular Switch piano flush type, single pole, one way, and 15/16 Amp single module complete all as specified. |
| 84 | S & F for Modular Socket outlet multipurpose having provision for 3 pin, 5/6 Amp and 2 pin, 5/6 Amp, 2 module piano flush type complete all as specified. |
| 85 | S & F for Modular Socket outlet multipurpose having provision for 3 pin, 15/16 Amp and 3 pin, 5/6 Amp, 2 module piano flush type complete all as specified. |
| 86 | S & F for modular step type fan regulator 120 watt 2 module suitable for 230 volt 50 Hz AC supply complete all as specified and as directed. |
| 87 | Supply and replace single core cable PVC insulated and unsheathed multistranded copper conductor of size 1.5 Sqmm from point wiring including removal old existing unserviceable one complete all as specified and directed. |
| 88 | Supply and replace single core cable PVC insulated and unsheathed multistranded copper conductor of size 2.5 Sqmm from point wiring including removal old existing unserviceable one complete all as specified and directed. |
| 89 | Supply and replace single core cable PVC insulated and unsheathed multistranded copper conductor of size 4 Sqmm from point wiring including removal old existing unserviceable one complete all as specified and directed. |
| 90 | M & L for Sub main wiring with approved colour coding as per IS with two single core PVC insulated frlshHH cable with stranded copper conductor of size 4.0 Sqmm nominal area and drawing into PVC non metallic rigid heavy duty PVC conduit of white/ ivory colour and its accessaries ISI marked heavy duty of suitable size concealed in wall etc including one run of PVC insulated 4 Sqmm (nominal area) stranded copper conductor frlshH cable as earth wire complete all as specified and as directed. Note:- Two runs of 4.0 sqmm cable,one run of 4 sqmm cable and one run of PVC casing caping will be measured as one unit |
| 91 | M & L for Sub main wiring with approved colour coding as per IS with two single core PVC insulated frlshH cable with stranded copper conductor of size 6 Sq mm nominal area and drawing into PVC non metallic rigid heavy duty PVC conduit of white/ ivory colour and its accessaries ISI marked heavy duty of suitable size including concealed in wall etc one run of PVC insulated with 6.0 Sqmm (nominal area) stranded copper conductor frlshH cable as earth wire complete all as specified and as directed. Note:- Two runs of 6 sqmm cable,one run of 6 sqmm cable and one run of PVC casing caping will be measured as one unit |
| 92 | M & L for Sub main wiring with approved colour coding as per IS with two single core PVC insulated frlshH cable with stranded copper conductor of size 4.0 Sqmm nominal area and drawing into PVC non metallic rigid heavy duty PVC casing caping of white/ ivory colour and its accessaries ISI marked heavy duty of suitable size in wall etc including one run of PVC insulated 4 Sqmm (nominal area) stranded copper conductor frlshH cable as earth wire complete all as specified and as directed. Note:- Two runs of 4.0 sqmm cable,one run of 4 sqmm cable and one run of PVC casing caping will be measured as one unit |
| 93 | M & L for Sub main wiring with approved colour coding as per IS with two single core PVC insulated frlshH cable with stranded copper conductor of size 6 Sq mm nominal area and drawing into PVC non metallic rigid heavy duty PVC casing caping of white/ ivory colour and its accessaries ISI marked heavy duty of suitable size in wall etc one run of PVC insulated with 6.0 Sqmm (nominal area) stranded copper conductor frlshH cable as earth wire complete all as specified and as directed. Note:- Two runs of 6 sqmm cable,one run of 6 sqmm cable and one run of PVC casing caping will be measured as one unit |
| 94 | S & F for sheet metal enclosure MCB DB TPN 4 way Vertical type with 200 Amps rated bus bar 415 volts double door with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed. |
| 95 | S & F for sheet metal enclosure MCB DB SPN 8 way with 200 Amps rated bus bar 240 volts double door with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed. |
| 96 | S & F for sheet metal enclosure MCB DB SPN 4 way with 200 Amps rated bus bar 240 volts double door with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed. |
| 97 | S & F MCCB TPN 415 volts 25 KA suitable for fixing on DB of capacity 100 Amps with extended terminals complete all as specified. |
| 98 | S & F for MCB tripple pole and neutral rated capacity 63 Amps, 415 volts breaking capacity 10 KA including removal of old unserviceable one complete all as specified and as directed. |
| 99 | S & F for MCB Single pole and neutral rated capacity 32 Amps, 240 volts breaking capacity 10 KA including removal of old unserviceable one complete all as specified and as directed. |
| 100 | S & F for MCB Single pole and neutral rated capacity 40-63 Amps, 240 volts breaking capacity 10 KA including removal of old unserviceable one complete all as specified and as directed. |
| 101 | S & F for MCB Single pole rated capacity 5 to 32 Amps, 240 volts breaking capacity 10 KA including removal of old unserviceable one complete all as specified and as directed. |
| 102 | S & F ceiling fan regulator socketed, step type, flush type heavy duty suitable to work on 230 volts AC supply including removal of old unserviceable one complete all as specified. |
| 103 | S & F for Lamp holder, PVC body suitable for batten fitting completes all as specified. |
| 104 | S & F for sheet metal enclosure MCB DB VTPN 4 way with 200 Amps rated bus bar 415 volts double door with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed.Make : Schneider, Havells, ABB. |
| 105 | S & F for Energy saving new generation environmental friendly long life versatile presure die cast aluminium IP 66 for security light fitting luminaire with high power LEDs as light source and electronic driver of capacity not less than 25 watts with pre wired, and necessary mounting arrangements and provision of 2.5 sq mm three core copper conductor cable multi stranded from ceiling rose to light fitting including necessary dia GI pipe medium grade bracket 1.5 mtr long bend to required shape with clamps, nut, bolts complete all as directed by Engineer- in-charge. Cat part No Jaquar- OSL-GRY-LPCRSRT25WLC/ Bajaj- VISTA P 32L WH PO PC SD / Crompton- TRP-415-25-57-SL-LM-NBK |
| 106 | S & F for Energy saving new generation environmental friendly long life versatile presure die cast aluminium IP 66 for security light fitting luminaire with high power LEDs as light source and electronic driver of capacity not less than 45 watts with pre wired, and necessary mounting arrangements and provision of 2.5 sq mm three core copper conductor cable multi stranded from ceiling rose to light fitting including necessary dia GI pipe medium grade bracket 1.5 mtr long bend to required shape with clamps, nut, bolts complete all as directed by Engineer- in-charge. Cat part No Jaquar- OSL-GRY-LSRT015045XC / Bajaj- VISTA P 58L WH PO PC SD / Crompton- TRP-417-45-57-SL-LM-NBK |
| 107 | S & F for Energy saving new generation environmental friendly long life versatile presure die cast aluminium IP 66 for security light fitting luminaire with high power LEDs as light source and electronic driver of capacity not less than 60 watts with pre wired, and necessary mounting arrangements and provision of 2.5 sq mm three core copper conductor cable multi stranded from ceiling rose to light fitting including necessary dia GI pipe medium grade bracket 1.5 mtr long bend to required shape with clamps, nut, bolts complete all as directed by Engineer- in-charge. Cat part No Jaquar- OSL-GRY-LSRT015060XC / Bajaj- VISTA P 78L WH PO PC SD / Crompton- CRP-421-70-57-SL-LM-NSG |
| 108 | S & F for Energy saving new generation 10 watts LED bulk head fitting IP 65 luminaire with opel diffuser pre wired and necessary mounting arrangements , provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting including LED bulb complete all as specified and as directed. Cat part No Jaquar- ILO-BLK-LBLK03X010XW / Bajaj- 112334 BIBWP 10 W LED / Crompton- LBHE-10-CDL |
| 109 | M&L for sheet metal enclosure MCB DB, SPN, 240 volts, 12 way, double door type grouting in wall in CM, making good of disturbed surfaces and matching with existing and electrical connections complete. |
| 110 | Supply and fixing for sheet metal enclosure MCB DB, IP-43, SPN, 240 volts ,8 way, double door type grouted in wall in cement mortar 1:3 and making electrical connection, complete all as specified and directed and including taking down old DBs and take to schedule of credit. |
| 111 | Supply and fixing MCB SP, 6 to 32 Amps, 240 volts, 10 KA, 'C' Curve characteristics, including taking out old unserviceable MCB/Isolator, electrical connections and removal from the site complete all as specified and directed. |
| 112 | Supply and fixing MCB SPN,32 Amps, 240 volts, 10 KA 'C' Curve characteristics, including taking out old unserviceable Isolator & electrical connection and removal from the site complete all as specified and directed. |
| 113 | Supply and fixing MCB SPN,40 to 63 Amps, 240 volts, 10 KA 'C' Curve characteristics, including taking out old unserviceable Isolator & electrical connection and removal from the site complete all as specified and directed. |
| 114 | Supply and fixing in replacement of TPN Vertical Type Distribution Board, IP-43 protection, fitted with bus bars, neutral links, blanking plates (with out MCCB), 415 volts, 4 way double door type, grouted in wall in cement mortar 1:3 and making good of disturbed surface and matching with existing surface, complete all as specified and directed and including taking down old DBs. |
| 115 | Supply and fixing in replacement of MCCB, 4P, rated current 63 Amp, breaking capacity 16/18 kA thermal magnetic type and making electrical connection, complete all as specified and directed and including taking down old mccb. |
| 116 | Supply and fixing in replacement of MCCB, 4P, rated current 100 Amp, breaking capacity 16/18 kA thermal magnetic type and making electrical connection, complete all as specified and directed and including taking down old mccb. |
| 117 | Supply/ boring and fixing of Earth electrode 17.2 mm dia 3 mtr long of low carbon steel electrode with copper bonding of thickness 250 micron, Back-fill earthing enhancing compound type Carbon based compound conductive concrete type which has a resistivity of less than 0.12 Ohm Mtr as per Clause 14.5D of IEEE : 80 standard. Back-fill compound should be electronically conductive (Like in metals) and should not depend on moisture for conduction. Back-fill comound should be environment friendly & should be solidify when mixed with water and set like concrete and should not leach / diffuse into the ground. Back-fill compound shall not be mixed with any soil while pouring in the bore hole. Test Certificate as per as per IEC: 62561-7 for Back-fill compound shall be submitted along with the material including SS clamp to be provode both side complete all as specified Note - (i) Earth electrode should be applicable Standards IS: 3043, IEC 62561-2 & IEC 60364-5 and made of High Tensile steel rods copper bounded, High tensile strength,good electrical conduction & effective performance and suitable for all type of soil and provided minimum distance 3 Mtrs. (ii) Back-fill compound should be Compliance to the Standards IEEE: 80, IS-3043, BS 7430, IEC 62561-7, ANSI/NSF 60 Certification.(iii) Positive low resistance electrical connection to the earth. (iv) Does not contain hazardous chemicals.(v) Electronically conductive (like in metals) and is not dependent on moisture.(v) Provide the desire value of earth resistance as per required specified values and Test result to be provide of electrodMake : OBO Beetermann/ Axis / VTR |
| 118 | Taking down unsv earth continuity conductor of any type and size but S&F in replacement Earth continiuty conductor or main earthing lead fixed on wall on batten or recess or chases or buired in ground or drawn in conduit / pipe or fixed to wall up to test point / laying in below ground drown in GI tubing or any other indicated suituation for loop earthing etc, as required for galvanised iron wire 4 mm dia with proper saddles / spacer, screw etc, alll as specified and directed. |
| 119 | Description all as per Ser item No 109 above but 25×4 mm galvanised iron strip . |
| 120 | Description all as per Ser item No 109 above but 25×3 mm aluminium strip . |
| 121 | Description all as per Ser item No 109 above but 20x3 mm copper strip |
| 122 | Taking down unsv any type and size of GI tubing but S&F in repair for 40 mm bore galvanised steel water tubing medium grade with all fitting fixed to wall and ceiling or laid in floors complete all as specified and as directed. |
| 123 | Taking down unsv chamber of any type and size but M&L for earthing chamber of size 0.45 x 0.45x 0.45 m and 100 mm thick by PCC 1:3:6 type C1 with 20 mm graded stone chamber with RCC 1:2:4 type B1 in cover slab complete all as specified and as directed. Please Enable Macros to View BoQ information |