| 1 | A) Extension and erection of 11KV OHL with installation of distribution transformers, foundation etc work to provide power to new crusher and Charging point at Topa OCP under Kuju Area. |
| 2 | A) (a) 11 KV OH Line renovation |
| 3 | Supplying and erection of 11 KV pin insulator complete with largesteel head G.I. pin, nuts, washers etc. as required. |
| 4 | Supplying and erection of 11 KV disc insulator for 11 KV overhead lines with galvanised insulator fittings, ball and socket typeand complete with galvanised strain clamps, bolts, nuts, washers etc. as required. |
| 5 | Supply of G.I. wire 8 SWG ( Galvanized Iron Fencing Wire 115.00- 17.54 = 97.46) Less 18% GST) Cradling 4 places X 50 Mtr X 6 WIRE X 131 Kg P/Kmtr X 1.05 =165.06 Kg |
| 6 | Erection of G.I. Wire No. 8 SWG including binding etc. as required |
| 7 | Erection of ACSR conductor of 7/3.35 mm to 7/4.00 diameter andabove including binding etc. as required.`600 Mtr X 3 WIRE X 394 Kg/Pmr X 1.05=744.66 CUM |
| 8 | Erection of ACSR conductor of 7/3.35 mm to 7/4.00 diameter andabove including binding etc. as required.Earthing Continue 600 Mtr X 1 WIRE X 214 Kg/Pmr X 1.05=134.82 Kg |
| 9 | Erection of pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40mm nominal size) foundation including excavation and refilling etc. as required.Above 10.00 metre and upto 12.00 metre |
| 10 | Supplying of channel iron 75 mm X 40 mm X 6 mm (7.14 kg permetre) pole top bracket/ cross arm for single 11 KV over head line conductor complete with 50 mm X 6mm flat iron clamp, bolts, nuts and washers including drilling holes for insulator pins, bolts and nuts etc and painting with primer and finish paint as required. |
| 11 | Supplying of channel iron 75 mm X 40 mm X 6 mm (7.14 kg permetre) cross arm for two 11 KV over head line conductorscomplete with 50 mm X 50 mm X 6 mm (angle iron bracket welded to the channel iron and complete with 50 mm X 6mm M.S. flatiron clamps, bolts and nuts including drilling holes for insulatorpins, bolts, nuts and washers etc (as per drawing) and painting with primer and finish paint as required. |
| 12 | Supplying and erection of bow stay set complete (galvanised)with 19/20 mm dia X 1.8 metres long stay rod, anchor plate ofsize 45 cm X 45 cm X 7.5 mm, thimble, stay clamps, turn buckle( 20 mm X 60 cm ), 7/ 4.00 mm dia G.I. stay wire and strain insulator etc in cement concrete 1:3:6 (1 cement : 3 coarse sand: 6 graded stone aggregate 40 mm nominal size ) foundationincluding excavation and refilling and also with 0.6 m long braceof size 50 mm X 50 mm X 6 mm angle iron with 50 mm dia pulleyfixed at one end of the brace as required. |
| 13 | Supplying of two lengths of channel iron 75 mm X 40 mm X 6 mm(7.14 kg per metre) double pole cross arm for three wire 11KVover head line conductors complete with through bolts and nuts for clamping to the poles, 50 mm X 6 mm M.S. flats welded onone side to the channel iron and with bolts and nuts on the otherside for tying the cross arms together, including drilling holes forinsulator pins/ fittings, bolts, nuts and washers etc (as per drawing)and painting with primer and finish paint as required. |
| 14 | Supplying and erection of a set of cross bracing FRLSame workfor 11 KV over head line double pole structure having four membersfabricated out of 50 mm X 50 mm X 6 mm angle iron to form a rectangle of minimum size 1400 mm width X 2500 mm height ,complete with 50 mm X 6mm M.S. flat iron clamps, bolts andnuts including drilling holes for insulator pins, bolts and nuts etc(as per drawing) and painting with primer and finish paint as required. |
| 15 | Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required:70 sq. mm |
| 16 | Supply & Fixing of 11 KV grade Air Break Switch 630Amp horizental type |
| 17 | Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 18 | Supply & Fixing of Aluminium Unarmoured single core flexible type 1100 voltage grade 35 sq mm |
| 19 | Supply & Fixing of Aluminium Tubular Lug 35 sq mm |
| 20 | Supply & Fixing of 11KV Drop out fuse, 400Amp |
| 21 | Supply & Fixing of Lighting Arrestor Station Type 3.3 KV |
| 22 | Supply & Fixing of Support Insulator 65mm dia and 50mm long |
| 23 | Supply & Fixing of Pad / Palm Connector, aluminium alloy material, 48.60 mm X 12 mm size |
| 24 | Supply & Fixing of PG Clamp |
| 25 | A) (b) LT Control Panel. |
| 26 | Supply & Fixing of CT ring type 300/5 |
| 27 | Supply & Fixing of Indicating Lamp 220Volt AC/DC |
| 28 | Supply & Fixing of Fuse Base & Carrier 16Amp, 110Volt |
| 29 | Supply & Fixing of Volt Meter 4\\" sq mm |
| 30 | Supply & Fixing of Amp meter 4\\" sq mm range (120/5) |
| 31 | Wiring with ferruls & Lugs |
| 32 | Supply & Fixing of 4 pole MCCB DN3-400N (Release Range 160-400) |
| 33 | Supply & Fixing of 4 pole MCCB DZ0-125D (Release Range 80-100) |
| 34 | Painting, nut & Bolts as required |
| 35 | Supply & Fixing of Support Insulator 65mm dia and 50mm long |
| 36 | Supply & Fixing of Aluminum Flat Bar 50mm X 10mm |
| 37 | Supply & Fixing of Fiber Glass Tape with Adhesive |
| 38 | Supply & Fixing of Energy Meter Aux supply 80-300 VAC/DC |
| 39 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer usingstructural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works |
| 40 | A) (c ) Foundation Woks |
| 41 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil 3 Mtr X 0.24 Mtr X 1 .5 Mtr X 2=2.16 CUM2 Mtr X 2 Mtr X 1 Mtr X 4=16 CUM |
| 42 | Brick work with common burnt clay F.P.S. (non modular) bricks of classdesignation 7.5 in foundation and plinth in: :Cement mortar 1:6 (1 cement : 6 coarse sand) 3 Mtr X 1.50 Mtr X 0.24 Mtr X 2 Wall X 2=4.32 CUM1.76 Mtr X 1.50 Mtr X 0.24 Mtr X 2 Wall X 2=2.53 CUM2 Mtr X 1.50 Mtr X 0.24 Mtr X 2 Wall X 4=5.76 CUM1.76 Mtr X 1.50 Mtr X 0.24 Mtr X 2 Wall X 4=5.06 CUM |
| 43 | Cement plaster skirting up to 30 cm height, with cement mortar 1:3 (1cement : 3 coarse sand), finished with a floating coat of neat cement.18 mm thick |
| 44 | Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire ornuts, bolts and washers as required complete as per the direction of Engineer-in- charge Made of Made of G.I. wire of dia. 4 mm, PVC coated to achieve outer dia not less than 5 mm in required colour and shade 15 Mtr X 7 Mtr X 2 Set X 2 Mtr =420 SQM |
| 45 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :- All work up to plinth level 1:4:8 (1 Cement : 4 coarse sand (zone-Ill) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) 3 Mtr X 2 Mtr X 0.24 Mtr X 2=2.88 CUM2 Mtr X 2 Mtr X 0.24 Mtr X 2=1.92 CUM For Fencing0.50 Mtr X0.50 Mtr X 0.50 Mtr X 40 Nos=1.75 CUM |
| 46 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size in the existing RCC/ HUME/METAL pipe as required.Upto 120 sq. mm |
| 47 | Supply & Fixing of Cable 400 sq mm X 4 core Armoured aluminium |
| 48 | Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. 1.76 Mtr X 1.76 Mtr X 1.25 Mtr X 4 Nos=15.482.76 Mtr X 1.76 Mtr X 1.25 Mtr X 2 Nos=12.14 |
| 49 | Installation of HT, LT SWITCH & Transformer set and termination by providing man power |
| 50 | B) Shifting of 1.6MVA,11KV/3.3KV Power transformer from Pindra to Topa OCP and 1MVA ,11KV/3.3KV Transformer from Topa to Pindra Project. |
| 51 | Supply & Fixing of Air Break Switch 11KV grade, 630 Amp |
| 52 | Supply & Fixing of Pad / Palm Connector, aluminium alloy material, 43.60 mm X 12 mm size |
| 53 | Supply & Fixing of T Connector, aluminium alloy material, 48.60 mm size |
| 54 | Supply & Fixing of Pipe to Pipe Connector, aluminium alloy material, 48.60 mm X 48.60 mm size |
| 55 | Supply & Fixing of Support Connector, aluminium alloy material, 48.60 mm size |
| 56 | Supply & Fixing of Post Insulator, 10KA, 11KV rated, standard size |
| 57 | Supply & Fixing of Nut & Bolts |
| 58 | Supply & Fixing of Alloy aluminium pipe 48.3 mm dia inner dia 40.8 mm wall thk 3.6 mm |
| 59 | Supply & Fixing of Bi-Metallic connector, aluminium alloy material/brass, 48.60 mm X 12 mm size |
| 60 | Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories. |
| 61 | Supply & Fixing of Aluminium Unarmoured cable single core 1100 voltage grade 35 sq mm |
| 62 | Supply & Fixing of Aluminium Tubular Lug 35 sq mm |
| 63 | Supply & Fixing of Cork Sheet 6mm, 3 Feet X 2 feet |
| 64 | Online Oil Filtration of Transformer at site |
| 65 | Supply & Fixing of Limit Switch, 800mA, 250V, 10A |
| 66 | Supply & Fixing of Cable 2.5 sq mm x 2 core copper |
| 67 | Dismantling and installation of 1.6 MVA Power Transformer 11KV/3.3KV with bus bar and termination at Topa, 1 MVA at Pindra 11KV/3.3KV |
| 68 | C) Diversion of 3.3KV Overhead lines from 2.6MVA Dudhmatia Main Substation under Topa project. |
| 69 | Errection of tubular pole of length exceeding 10 M but not exceeding 12M in cement concrete 1:3:6 (1 cement:3 coarse: 6 graded stone aggregate 40 mm nominalsize) foundation including excavation & refilling etc as required |
| 70 | Erection of All alluminium conductor of 7/1.96 to 7/4.0 mm dia and above including binding etc as required. 14 Span x 0.394 Kg/M (DOG) x 50 M x 3 wire |
| 71 | Supplying and erection of bow stay set complete (galvanised) with 19/20 mm dia X 1.8 metres long stay rod, anchor plate ofsize 45 cm X 45 cm X 7.5 mm, thimble, stay clamps, tum buckle(20 mm X 60 cm), 7/4.00 mm dia G.I. stay wire and strain insulator etc in cement concrete 1:3:6 (1 cement: 3 coarse sand: 6 graded stone aggregate 40 mm nominal size) foundationincluding excavation and refilling and also with 0.6 m long braceof size 50 mm X 50 mm X 6 mm angle iron with 50 mm dia pulleyfixed at one end of the brace as required. |
| 72 | Supplying of two lengths of channel iron 75 mm X 40 mm X 6 mm(7.14 kg per metre) double pole cross arm for three wire 11KV over head line conductors complete with through bolts and nuts for clamping to the poles, 50 mm X 6 mm M.S. flats welded onone side to the channel iron and with bolts and nuts on the otherside for tying the cross arms together, including drilling holes forinsulator pins/fittings, bolts, nuts and washers etc (as per drawing)and painting with primer and finish paint as required. |
| 73 | Supplying and erection of a set of cross bracing FRLSame work for 11 KV over head line double pole structure having four membersfabricated out of 50 mm X 50 mm X 6 mm angle iron to form a rectangle of minimum size 1400 mm width X 2500 mm height,complete with 50 mm X 6mm M.S. flat iron clamps, bolts andnuts including drilling holes for insulator pins, bolts and nuts etc(as per drawing) and painting with primer and finish paint as required. |
| 74 | Supplying of channel iron75mmX40mmX6mm(7.14kgpermetre) pole top bracket /cross arm for single11KV overhead line conductor complete with 50mmX6mm flat iron clamp, bolts, nuts and washers including drilling holes for insulator pins, bolts and nut set cand painting with primer and finish paint as required |
| 75 | Supplyingof50mmX8mmM.S.Batironpoletopbracket/crossarmfor single 11/22/33KVoverheadlineconductorcompletewithfixingclamps, bolts, nutsandwashersdrillingholesforinsulatorpins, boltsandnutsetc and painting with primer and finish paint as required. |
| 76 | Supplying and erection of 11 KV pin insulator complete with large steel head G.I. pin, nuts, washers etc. as required. For replacement of damaged pins Insulator in complete Overhead line |
| 77 | Supplying and erection of 11 KV disc insulator for 11 KV overhead lines with galvanised insulator fittings, ball and socket typeand complete with galvanised strain clamps, bolts, nuts, washers etc. as required. For replacement of damaged disc insulator in complete Overhead line |
| 78 | supplying and erecting earth pit of minimum bore dia. 150mm size, approved make Safe Earthing Electrode consisting Pipe-in-Pipe technology as per IS 3043-1987 made of corrosion free G.I. Pipes with constant ohmic value surrounded by highly conductive compound with high charge dissipation suitable for effective and maintenance free earthing as mentioned below: With 3 mtr. G.I. Pipes having outer pipe dia of 50mm having 80-200 micron galvanizing, Inner pipe dia. of 25mm having 200-250 Micron galvanizing. connection terminal dia of 12mm in nominal soil with 50 kg (Two Bag) Back filling Compound |
| 79 | Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m inwidth as well as 10 sqm on plan) including disposal of excavatedearth, lead upto 1.5 m, disposed earth to be levelledand neatly dressed. 2.8.1 Ordinary rock. For earthpit enclosure 0.5 Mtr X 0.5 Mtr X 0.5 Mtr X 2 no. 0.25 CUM |
| 80 | Brick work with common bunt clay modular bricks of class designation7.5 in foundation and plinth in:Cement mortar 1:4 (1 cement: 4 coarse sand) For Earthpit enclosure 1M X 0.5M X 0.13M X 2 wall + 1M X0.24M X 0.13M x 2 wall= 0.1924 Cu.M. x 2 earthpit = 0.3848 Cu.M. |
| 81 | Cement plaster skirting up to 30 cm height, with cement mortar 1:3 (1cement: 3 coarse sand), finished with a floating coat of neat cement. 18 mm thick For earthpit 0.5 Mtr X 0.5 Mtr X 4 wall X 2 Side x 212 SQM. |
| 82 | Providing and laying in position specified grade of reinforced cemen concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level 1:2:4 (1 cement: 2 coarse sand (zone-III) derived from natural sources: 4 graded stone aggregate 20 mm nominal size de rived from natural sources) Earthpit cover 0.5 Mtr X 0.5 Mtr X 0.13 Mtr X 2 = 0.065 Cu.M |
| 83 | Supply & installation of Aluminum armoured cable single core 1100 voltage grade 35 sq mm. for earh connection |
| 84 | Supply & installation of Aluminum Tubular Lug 35 sq mm for earh connection |
| 85 | Dismantling of pole/street light standard/strut embeded in cement concrete etc as req. |
| 86 | Dismantlingofoverheadlinescomprisingofcopper/aluminiumoverhead conductor, Cl. wire, cross arms, insulators etc, as required. |
| 87 | Supply of 8 swg G.I. wire for cradling. 4 wire cradling - 50M*4 wire 4 cradling + 1.5M 60 no. 4 cradling = 1160 Mtrs. Weight = 0.103 Kg/M 1200 = 120Kg |
| 88 | Erection of G.I. Wire No. 8 SWG including binding etc. as required. 50M*4 wire 4 cradling = 800 Mtrs. Weight= 800*0.103 |
| 89 | Erection of cradle guard as required. 60 no. 4 cradling |
| 90 | Painting of Tubular pole of Length 11 M (19 Nos.) Including painting of cross brace and cross arms. Total painting area= Pole-19 x 9.04 + SP cross arm-03 x 0.62 + DP cross arm-08 x 2 x 0.62 + Cross brace - 13 x 2.12 |
| 91 | Supply & fixing of 11KV GOAB switch with all accessories |
| 92 | D) Arrangement of Auxiliary power supply for backup for tripping devices at Main Subsattion of Topa Project under Kuju Area. |
| 93 | Supply & Fixing of 110V DC Battery Bank (Tubular Battery, consisiting of 55 Nes (2V each cell), capacity 150AH) |
| 94 | Supply & Fixing of Battery Charger to charge the power pack, input volt AC output 110V IC power supply ranges from 0 to 1000 V and output current ranges from 0 to 100 Amp |
| 95 | Supplying and drawing following sizes of FRL SPVC insulated copper conductor, single core cable in the existing surface/rocessed steel PVC conduit as required. 2x4 sqmm |
| 96 | Supplying and drawing single core PVC insulated cable FRLS with copper multi strand conductor ISI marked in existing rigid PVC casing and capping/conduit in surface or concealed as per specification. 225 sqmm |
| 97 | Supplying and fixing of following ways surface/recess mounting, vertical type, 415 V. IPN MOB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, carth bar, din bar for mounting MCBs (but without MCBs and incomer) as required. (Note: Vertical type MOB TPDB is normally used where 3 phase outlets are required.)4 way (4+12), Double door |
| 98 | Supplying & fixing suitable size Gl box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \\"C\\" curve including connections, painting etc. as required. |
| 99 | Supply & Fixing of Copper flat for series connection of battery 25mm width and 3mm thick |
| 100 | Supply & Fixing of Battery Terminal, Heavy Duty, 35SQMM |
| 101 | Supplying of metal clad ISI marked busbar chamber made of heavy gauge iron sheet complete with copper strip and busbar supports as per specification conforming to IS -4064 400A 415V |
| 102 | Total impact of GST for the purpose of CTC Please Enable Macros to View BoQ information |