| 1 | DSR item No. 1.17 Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. |
| 2 | 3 x 1.5 sq. mm |
| 3 | DSR Item No. 2.4 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without (MCB/RCCB/Isolator) |
| 4 | 4 way (4 + 12), Double door |
| 5 | DSR item No. 2.10 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 6 | Single pole |
| 7 | Triple Pole & Neutral |
| 8 | DSR 5.2 Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. |
| 9 | DSR 5.7 Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required. |
| 10 | DSR item No.2.2 Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, Ics=100% Icu and Operational Voltage 690V etc. as required. |
| 11 | 100 A,30KA,FPMCCB |
| 12 | DSR item No.8.16 LED Flood Light, powder coated pressure die cast aluminium (System lumen efficacy ≥120 and <135 lm/Watt). (Please refer DNIT for complete specification of item no.7) |
| 13 | 100 Watt. |
| 14 | 250 Watt. |
| 15 | Carriage and erection of existing steel tubular pole 7.5 mtr./ 9 mtr. height with the help of hydraulic ladder/ crane with bucket which shall be arranged by the firm at his own cost as required at site. The pole shall be erected 1.5 mtr. below ground level in 12” internal dia ready made RCC muff 1.5 mtr. in length after digging the pit. The gap between the pole and muff shall be filled with cement sand and concrete mixture ratio 1:2:4. The cost includes carriage, all labour and other petty material required to complete the job to the entire satisfaction of the Engineer-in-Charge. |
| 16 | Supply & Laying of PVC insulated sheathed aluminium conductor un armored flat cable 16 mm. sq. 2 core in existing pole 9 mtr. height with the help of hydraulic ladder/ crane with bucket which shall be arranged by the firm at his own cost. The job also includes cost of making connection and other petty material etc. as required at site to complete the job to the entire satisfaction of Engineer-in-charge. The cable should be of Polycab/ Havells/ RR Kable/ KEI/ Finolex make only. |
| 17 | Supply and laying of XLPE insulated PVC sheathed Aluminum conductor armoured cable of 1.1 KV grade as per IS 7098 (Part-I) 1988 (amended up to date) of the following sizes to be laid in existing Trench/ pipe as required at site to the entire satisfaction of Engineer-in-Charge. The job includes labour charges of laying the cable and making connections with suitable size aluminum lugs/thimbles etc. The cable shall be of Polycab / Havells / R.R. Kabel/ KEI/ Finolex make only. |
| 18 | 10 sq.mm 4 core |
| 19 | Supply and erection of MS bracket F type suitable size and suitable shape made form 40mm x 40mm x 5mm thick angle iron to be installed on exiting parapet/ wall with help of suitable size of nuts and bolts etc. for erection of existing LED flood light fittings. The job also includes the cost of painting of box with superior quality of paint and other petty material etc as per required to complete the job. |
| 20 | S/E of angle iron bracket 3' long made out of 50mm x 50mm x 5mm with 4\\" dia 45 cm long GI pipe medium class canopy suitable for installation of existing 2 nos. LED flood lights. The bracket shall be welded to GI pipe canopy at the top of the pole. The bracket shall be provided with at least 3 nos. nut/bolts ½” dia crossed through out the pole & the bracket complete with washer etc.(Please refer DNIT for complete specification of item no.12) Please Enable Macros to View BoQ information |