| Sl. No. | Item Description |
| 1 | SH: I (11 KV H.T. VCB THREE BREAKER PANEL BOARD (INDOOR TYPE) (1 INCOMMING + 2 OUTGOING)Supplying, Installation, Testing & Commissioning of indoor type panels shall be constructed from CRCA or Aluminium Zinc coated steel sheet of minimum 2 mm thickness, floor mounted metal enclosed, 11 KV VCB panel, totally enclosed and fully interlocked, horizontal draw out, horizontal isolation type breaker as per IS 13118, as amended up to date and additional specifications, having capacities as mentioned below, single break, trip free mechanism, manually charged and manually closing breaker suitable for use on 11 KV, 3 phase, 50 Hz A.C. supply with short circuit fault level of minimum 26.3 kA , Panel shall be full internal arc tested i.e. in all three chambers at minimum 26.3kA for 1 sec for safety purpose (AFLR).Make of Vacuum interrupter, circuit breaker, numerical relay & Panel shall be same. . Each pole of VCB including VI should be completely epoxy insulated (partial encapsulation on accepted) for safety from vermin, dust etc Offered Panel compete with self contained, fully interlocked, rack in and rack out mechanism, air insulated copper bus bars of 800 amps capacity, Busbar should be covered with HT full voltage sleeve (Heat shrinkable PVC sleeve not accepted). Breaker featured with mechanical ON/ OFF indicator with hand trip coil, integral spring charging handle and auxiliary switch of 4 NO+4NC and equipped with following switchgears and accessories. i/c connections suitable for 3 x 300sq. mm XLPE 11 KV cable (Cable entry from bottom) end termination with heat shrinkable jointing material etc as required and as per direction of Engineer-in-Charge. INCOMING PANEL - 1 NO & OUTGOING 2 NO11 kV, 800A, HT THREE Vacuum circuit breaker Switchboard (1I/C+2O/G ) with Aluminium Busbar - Indoor TypeIncomer-1 Nos.11 kV HTVacuum Circuit Breaker - 800 A, 3 pole = 1 No.ON/ OFF/TRIP/SPRING CHARGE/TRIP CIRCUIT HEALTHY indicating lamps. = 5 Nos. |
| 2 | Emergency Stop Push Button = 1 No.Phase indicating lamps = 3 Nos.Digital Voltmeter with selector switch. = 1 No.MFM (Multifunction Meter) with RS 485 port = 1 No.Control MCB SP/DP = 1 No.Inbuilt DC Power Pack = 1 No.Aux. relays for Anti Pumping & indication. = 1 No.Master trip relay. = 1 No.Over current and Earth fault based relay = 1 No.Cast resin CTs of dual ratio 200/100/5/ 5 Amps 5VA burden, CL:1.0 for Metering & 5P 10 for protection. = 3 Nos.Cast resin fixed type PTs 11 kV/ √3/ 110 √3, class 1, 100 VA. = 3 Nos.TNC Switch = 1 No.Anti- Condensation space heaters = 1 No.Outgoing 2 Nos. 11 kV HTVacuum Circuit Breaker - 800 A, 3 pole = 2 Nos.ON/ OFF/TRIP/SPRING CHARGE/TRIP CIRCUIT HEALTHY indicating lamps. = 10 Nos.Emergency Stop Push Button = 2 Nos.Digital Ammeter with selector switch. = 2 Nos.Control MCB SP/DP = 2 Nos.Inbuilt DC Power Pack = 2 Nos.Aux. relays for Anti Pumping & indication. = 2 Nos.Master trip relay. = 2 Nos.Over current and Earth fault based relay = 2 Nos.Aux relay 3c/o 24DC for TRF. fault. = 4 Nos.Cast resin CTs of dual ratio 100/50/5/ 5 Amps 5VA burden, CL:1.0 for Metering & 5P10 for protection. = 2 Nos.Cast resin fixed type PTs 11 kV/ √3/ 110 √3, class 1, 100 VA. = 2 Nos.8 window annunciator with Common hooter = 2 Nos.TNC Switch = 2 Nos.Anti- Condensation space heaters = 2 Nos.BUS Bar Aluminium. |
| 3 | TRANSFORMERSupply, installation, testing and commissioning of following capacity (continuous loading) 11/0.433 KV Delta/Star,step down, 3 Phase, 50 Hz, Dyn 11 vector group, Cast Resin / VPI (vacuum pressure impregnated) Dry Type, copper wound transformer (Electrolytic grade 99.9% pure copper, Core made of first grade Cold Rolled Grain Oriented (CRGO) Core grade MOH or better) AN (air natural) cooledtransformer suitable for indoor applications with Offload Tap Changer/ On Load Tap Changer (OLTC) ( upto 500 KVA offload and above 500 KVA On Load Tap Changer) on HV side having AVR relay and Remote Tap Changer Control (RTCC) for automatic sensing of incoming voltage, automatic operation of OLTC and facility for remote and manual operation of OLTC HV side in range of +5% to -15% in steps of 2.5%, insulation class F (minimum), suitable for environment conditions class E4, suitable for fire behaviour class F1,climate class-C1, having cable end boxes on HV side suitable for 3x300 sqmm XLPE cable of 11 KV grade with necessary hardware, clamps, lugs etc. for termination on HV/MV etc. for all transformers, bus trunking arrangement on LV side complete with all accessories and safety provisions as per relevant IS Code ,The transformer shall be provided with standard fittings/accessories as per relevant IS and mentioned below, protection alarm/trip protection, 3 nos. of Polymeric Zinc Oxide surge Arrestors on HV Side. Winding Temperature scanner (Digital) with alarm/Trip contacts with RTD Sensors per LV winding and space for mounting differential protection CT's in LV chamber with neutral brought out separately including supplying and laying of copper conductor multicore control cable from transformer to HT breaker/HT Panel for safety tripping, complete as confirming to IS-2026 Part-11, i/c supplying and grouting of suitable M.S. Channel with all accessories ,complete in all respects as required at site as per CPWD specifications . Design ambient condition : a) air temperature 50 0C, b) Relative Humidity 90 % Max, c) Seismic Zone as per location of site, d) Altitude as per location/site. The transformer should have QR code which should contain drawing, test report OEM manual,Geo- Tag of manufacturing location, rating plate as per relevant IS Code etc. All testing shall as per relevant IS Code. Noise level Shall not exceed limits as per NEMA TR-1 with all accessories running measured as per IEC 551/ NEMA Standard. Fitting and Accessories : The following fittings shall be provided:- a) Two earthing terminals with the earthing symbol b) Rating and terminal marking plates; c) Thermometer pocket with cap; d) Lifting lugs for the complete transformer as well as for core and winding assembly; e) Bi-directional flat rollers (for transformers above 200 kVA); f) HV side neutral grounding strip (where one of the HV bushing terminal is connected to earth); g) Arcing horns or suitable rating lightning arrestors for HT side – 3 Nos. for transformers up to 200 kVA; h) Bird guard; i) Jacking pads (for transformer above 1 600 kVA); j) Name Rating & Diagram Plate. k) Monogram Plate.i) Additional neutral separately brought out on bushing for earthing. Level 31250 KVA (losses at 50% loading < 3600watt, losses at 100% loading < 10750watt) |
| 4 | MAIN LT PANEL Supplying, installation, testing & commissioning of cubical modular type LT panel suitable for 415 V, 3 Phase, 4 Wire 50 Hz AC supply system fabricated in compartmentalized design having bus bar chamber duly fabricated from CRCA sheet steel of 2 mm thick for frame, back, sides, partition & doors and 3mm thick for glad plate duly powder coated in approved shade including cleaning & finishing complete with 7 tank process complete with 2500 Amp capacity extensible type four strip aluminium alloy bus bars of hight conductivity, DMC/ SMC bus bar supports having short circuit withstand capacity of 31 MVA for '1' Sec., bottom base channel of MS section not less than 100 mm x 50 mm x 5 mm thick, entire panel shall have a common earth bar of size 25 mm x 5 mm at the rear with 2 Nos. earth stud, solid connections from main bus bar to switch gears with required size of Al. bus bars, control wiring with 2.5 sq. mm. PVC insulated copper conductor single core cable, cooling / ventilation fans including construction of suitable CC foundation, in & out connections and providing & Fixing following switch gears therein etc. complete as required as per direction of Engineer-in-Charge. Incoming (from Transformer)(i) 2 Nos- 2000 Ampers four pole horizontal drawout type electrically operated air circuit breaker of fault breaking capacity 50 kA breaking capacity (Ics = Icu = Icw=100%) for 1 second suitable upto 690V, fitted with interlocked door, automatic safety shutters, mechanical ON/OFF and service/test/isolated position indicators and frame earthing contact, auxiliary contacts, shunt trip, interlocking features etc. complete with self powered Microprocessor based release for adjustable setting for over current, earth fault & short circuit protection with LCD display with current power & harmonic metering& pre overload and over temperature protection indication along with USB Port for communication & all other standard features conforming to IS 1397-2 : 1993 as amended up-to-date(ii) 2 Sets- RYB Phase indication LED lamps with 6A, 10KA, \\"C\\" Curve back up MCB, breaker ON/OFF/TRIP indicating light with 6A, 10KA, \\"C\\" Curve backup MCB(iii) 2 Nos.- 3 phase Intelligent multifunction digital meter to read V, A, KVA, KWH, PF Hz etc. with 3 Nos. resin cast CTs of 2000/5 A class 1.0 accuracy and 15 VA burden and with 3 Nos 6A, 10KA, \\"C\\" Curve back up MCB. |
| 5 | Bus Coupler(i) 1 Nos - 2000 Ampers four pole horizontal drawout type electrically operated air circuit breaker of fault breaking capacity 50 kA breaking capacity (Ics = Icu = Icw=100%) for 1 second suitable upto 690V with LSIG release, fitted with interlocked door, automatic safety shutters, mechanical ON/OFF and service/test/isolated position indicators and frame earthing contact, auxilary contacts, shunt trip, interlocking features etc.(ii) 1 Sets- RYB Phase indication LED lamps with 6A, 10KA, \\"C\\" Curve back up MCB, breaker ON/OFF/TRIP indicating light with 6A, 10KA, \\"C\\" Curve backup MCBBUS BARS:FP aluminium bus bars of minimum of 2500 A capacity with heat shrinkable colored sleeves and i/c DMC/SMC bus bars supports at required intervals complete, for cross section, size supports & their spacing etc. for withstanding fault level of 31 MVA for 1 Sec. Interlocking(i) INTERLOCKINGElectrical Interlocking through advance contacts in ACBs (Incomers) and mechanical (Castel key) Interlocking should be provided to ensure that only one supply is available at a time on each section of BUS and to eliminate any possible of accidently approaching two supplies at one BUS section with FRLS flexible copper wire. = 1 Job |
| 6 | Outgoing(i) 4 Nos.-800 Ampers four pole horizontal drawout type electrically operated air circuit breaker of fault breaking capacity 50 kA breaking capacity (Ics = Icu = Icw=100%) for 1 second suitable upto 690V, fitted with interlocked door, automatic safety shutters, mechanical ON/OFF and service/test/isolated position indicators and frame earthing contact, auxiliary contacts, shunt trip, interlocking features etc. complete with self powered Microprocessor based release for adjustable setting for over current, earth fault & short circuit protection with LCD display with current power & harmonic metering& pre overload and over temperature protection indication along with USB port for communication & all other standard features conforming to IS 1397-2 : 1993 as amended up-to-date(ii) 4 Sets- RYB Phase indication LED lamps with 6A, 10KA, \\"C\\" Curve back up MCB, breaker ON/OFF/TRIP indicating light with 6A, 10KA, \\"C\\" Curve backup MCB(iii) 4 Nos.- 3 phase Intelligent multifunction digital meter to read V, A, KVA, KWH, PF Hz etc. with 3 Nos. resin cast CTs of 800/5 A class 1.0 accuracy and 15 VA burden and with 3 Nos 6A, 10KA, \\"C\\" Curve back up MCB.(ii) 4 Set- 630A, FP, 36KA MCCB (Ics=Icu =100%) with Microprocessor based release with adjustable setting having O/L & S/C protection with Rotary handle and spreader terminal.(iii)16 Set- 400A, FP, 36KA MCCB (Ics=Icu =100%) with Microprocessor based release with adjustable setting having O/L & S/C protection with Rotary handle and spreader terminal. (iv) 8 Set- 250A, FP, 36KA MCCB (Ics=Icu =100%) with Microprocessor based release with adjustable setting having O/L & S/C protection with Rotary handle and spreader terminal.(v) 6 Set- 125A, FP, 36KA MCCB (Ics=Icu =100%) with Thermal based release with adjustable setting having O/L & S/C protection with Rotary handle and spreader terminal. (vi) 34 sets- 3 phase Intelligent multifunction digital meter to read V, A, KVA, KWH, PF Hz etc. with 3 Nos. resin cast CTs along with ON/OFF indicating light with 6A, 10KA, \\"C\\" Curve backup MCB, auxiliary contacts with MCCB |
| 7 | PHASE SEQUENCE CORRECTION PANELSupply, installation, testing and commissioning of Microprocessor Based Automatic Phase Sequence Corrector Panel for non stop smooth functioning of 3 phase critical equipments with built in protection like short circuit, over load, high/low voltage cut off of load from source in cubical type compartmentalized and fabricated from minimum 2 mm thick CRCA sheet having necessary cable alleys, powder coated including connection and interconnection as required as per specifications complete with 2000 Amp capacity, features and specifications:-Suitable for correcting the RYB phase sequence, whenever the sequence is changed or reversedAvoid damages during phase sequence changed or reversedIt should be:-1) Fully automatic.2) No manual intervention.3) Single phase prevention.4) Voltage imbalance protection between phases.output in the right sequence (R,Y,B)ON delay and OFF delay selectable and adjustable.Protects against phase unbalancing/phase loss/under and over voltages.Indications of R Y B Phase.2000 Amp 4 pole EDO type ACB- 2 Nos. |
| 8 | BUS TRUNKING Supplying, installing on wall, testing and commissioning of following capacity Air Insulated Compact Type Bus Trunking for use on 3 phase 4 wire 415 volts, 50Hz A.C. supply with metal clad enclosure made of 1.6mm thick steel sheet duly powder coated in convenient sections complete with 4 Nos aluminium bus bars, necessary joints, elbow joints & expansion joints, fire barrier at each floor, provision of tapping at every metre, continuous earthing with 2 Nos aluminium strip of suitable size (one on each side) including, G.I. clamping brackets, angle iron bracket, steel fasteners, connecting to earthing system etc. as required2500 A Isc = 50kA for 1 second |
| 9 | APFC PANELHYBRID Power Factor Correction SystemSupply, Installation, testing and commissioning ofHYBRID APFC Panel, 3 phase 4 wire, 415 V, 50 Hz AC System for Ambient temperature -5°C to +40°C of following capacity with passive solution of 60% capacity and active solution of 40% capacity, 3Phase 4 wire Hybrid Power Factor Correction Solution (with arrangement for neutral current balance) to achieve>0.99 lag and TDDI/THDV values within IEEE recommended limits.APFC should be designed as per IS 16636 Or IEC 61921. The active section and passive section shall work in sync to give optimized output. The degree of protection of passive section should be IP 42, and of active section should be minimum IP 21.The switching device for APFC passive section should be through capacitor duty contactor and for the active compensation system shall be IGBT based with 3 level topology having 12 IGBT in inverter circuit. The active compensation system should filter harmonics from 2nd to 50th individual harmonic order and shall be selectable for the entire range. The active compensation system should have feature to improve PF correction and harmonic filtration having response time < 100 Micro second. The hybrid panel shall be indoor type floor mounted free standing totally enclosed, extensible, fabricated in compartmentalised designed made of CRCA sheet steel of 2.0mm thick for framework & covers, 3 mm thick for gland plate i/c cleaning & finishing complete with 9 tank process for powder coated of approved shade ( RAL 7032-Siemens gray or as approved by Engineer-in-Charge), having front section (switch gear and control accessories) and rear section (capacitor and reactor), front and rear access, having suitable current carrying capacity, extensible TPN Aluminium alloy bus bar of high conductivity, DMC/SMC bus bar supports, bottom base channel of MS Section, fabrication shall be done in transportable section, entire panel shall have common copper earth bar of minimum size of 25mm x 5mm with 2 nos. earth studs, the earth terminals provided on the body of capacitor bank shall also be bonded to the main capacitor panel earth bus with 2 nos. 8 SWG or 6 SWG GI earth wires/ equivalent size of copper conductor cable, forced ventilation for maintaining temperature rise not more than 5°C from ambient, interconnections, connections with 14% detuned reactor and heavy duty 525 V ISI marked Impregnated MPP(Metalized Polypropylene) Capacitor (IS 13340 Part -1 & 2) APFC Panel shall be in compliance with IS :16636 & CPWD Specifications etc. as per below details.(A) IncomersSuitable capacity MCCB/ACB (Upto 300 KVAR, MCCB and above 300 KVAR, ACB ) Microprocessor base with O/C, S/C, E/L release of TPN 50KA breaking capacity (Ics=Icu), ON, OFF, Trip, R, Y, B - LED Indicating Lamp set alongwith required Instruments and accessories with extended rotary handel and door interlocking arrangement. Current rating of the Incomer in ampere shall be APFC Panel rating in KVAR x 1.4 x 1.5 or Nearest higher standards rating. (B) Instruments & Indications a)For Passive Section :i) 3-Phase current sensing APFC microprocessor relay/controller, advance 12/16 stages (12 stages for over all capacity of panel (active + passive) below 500 KVAR and 16 stages 500 KVAR & above) and having display of Phase wise V, A, PF, Cos-Phi, KW, KVA, KVAR, THD-V , THD-I, harmonics up to 31 level. |
| 10 | ii) Auto Manual Selector switch, auxiliary contactors with timer for delay in manual mode. iii) Digital Multi function meter with LED Display for V, A, PF, KW, KVA, KVAR, THD-V & I, Frequency.iv) Suitable rating control transformer shall be provided for control and indication circuit.v) All components like control transformer, meter, relay and indicating lamp shall be protected by using suitable rating individual MCB's.vi) Wiring of the control circuit shall be done by using 2.5 sq mm, FRLS/HFFR 1100 V grade, PVC insulated multi stranded copper control wire.vii) Communication Ethernet/RS485/SNMP port open protocol for BMS integration as per approved by Engineering in charge.b) For Active Section: Dedicated HMI (Human Machine Interface) (Minimum 7 inch display) for controlling and communication and having display of Phase wise V, A, PF, Cos-Phi, KW, KVA, KVAR, THDV , THD-I, harmonics up to 50th level. CommunicationEthernet/RS485/SNMP port open protocol for BMS integration as per approved by Engineering in charge. (a) 400 KVAR |
| 11 | MAIN EMERGENCY SUPPLY LT PANELSupplying, installation, testing & commissioning of cubical modular type LT panel suitable for 415 V, 3 Phase, 4 Wire 50 Hz AC supply system fabricated in compartmentalized design having bus bar chamber duly fabricated from CRCA sheet steel of 2 mm thick for frame, back, sides, partition & doors and 3mm thick for glad plate duly powder coated in approved shade including cleaning & finishing complete with 7 tank process complete with 800 Amp capacity extensible type four strip aluminium alloy bus bars of hight conductivity, DMC/ SMC bus bar supports having short circuit withstand capacity of 31 MVA for '1' Sec., bottom base channel of MS section not less than 100 mm x 50 mm x 5 mm thick, entire panel shall have a common earth bar of size 25 mm x 5 mm at the rear with 2 Nos. earth stud, solid connections from main bus bar to switch gears with required size of Al. bus bars, control wiring with 2.5 sq. mm. PVC insulated copper conductor single core cable, cooling / ventilation fans including construction of suitable CC foundation, in & out connections and providing & Fixing following switch gears therein etc. complete as required as per direction of Engineer-in-Charge. Incoming from DG(i)4 Nos- 630 Ampers four pole horizontal drawout type electrically operated air circuit breaker of fault breaking capacity 50 kA breaking capacity (Ics = Icu = Icw=100%) for 1 second suitable upto 690V, fitted with interlocked door, automatic safety shutters, mechanical ON/OFF and service/test/isolated position indicators and frame earthing contact, auxilary contacts, shunt trip, interlocking features etc. complete with self powered Microprocessor based release for adjustable setting for over current, earth fault & short circuit protection with LCD display with current power & harmonic metering& pre overload and over temperature protection indication along with USB Port for communication & all other standard features conforming to IS 1397-2 : 1993 as amended up-to-date(ii) 4 Sets- RYB Phase indication LED lamps with 6A, 10KA, \\"C\\" Curve back up MCB, breaker ON/OFF indicating light with 6A, 10KA, \\"C\\" Curve backup MCB(iii) 4 Nos.- 3 phase Intelligent multifunction digital meter to read V, A, KVA, KWH, PF Hz etc. with 3 Nos. resin cast CTs of 630/5 A class 1.0 accuracy and 15 VA burden and with 3 Nos 6A, 10KA, \\"C\\" Curve back up MCB. |
| 12 | Bus Coupler(i) 3 Nos - 630 Ampers four pole horizontal drawout type electrically operated air circuit breaker of fault breaking capacity 50 kA breaking capacity (Ics = Icu = Icw=100%) for 1 second suitable upto 690V with LSIG release, fitted with interlocked door, automatic safety shutters, mechanical ON/OFF and service/test/isolated position indicators and frame earthing contact, auxilary contacts, shunt trip, interlocking features etc.(ii) 3 Sets- RYB Phase indication LED lamps with 6A, 10KA, \\"C\\" Curve back up MCB, breaker ON/OFF indicating light with 6A, 10KA, \\"C\\" Curve backup MCBInterlocking(i) Electrical Interlocking through advance contacts in ACBs (Incomers) and mechanical (Castel key) Interlocking should be provided to ensure that only one supply is avialable at a time on each section of BUS and to eliminate any possible of accidently approaching two supplies at one BUS section with FRLS flexible copper wire. = 1 JobOutgoing(i) 10 Sets- 400A, FP, 36KA MCCB (Ics=Icu =100%) with Microprocessor based release with adjustable setting having O/L & S/C protection with Rotary handle and spreader terminal. (ii) 10 Sets- 250A, FP, 36KA MCCB (Ics=Icu =100%) with Microprocessor based release with adjustable setting having O/L & S/C protection with Rotary handle and spreader terminal.(iii) 12 Sets- 125A, FP, 36KA MCCB (Ics=Icu =100%) with Thermal based release with adjustable setting having O/L & S/C protection with Rotary handle and spreader terminal. (iv) 2 Sets- 100A, FP, 25KA MCCB (Ics=Icu =100%) with Thermal based release with adjustable setting having O/L & S/C protection with Rotary handle and spreader terminal. (v) 34 sets- 3 phase Intelligent multifunction digital meter to read V, A, KVA, KWH, PF Hz etc. with 3 Nos. resin cast CTs along with ON/OFF indicating light with 6A, 10KA, \\"C\\" Curve backup MCB, auxiliary contacts with MCCB |
| 13 | RECD SYSTEMSupplying installation, testing & commissioning of retrofit Emission control device on existing 250 KVA DG set to reduce Particulate Matter (PM), Hydro carbon and Carbon Monoxide emission by at least 70%. Device should be ‘Type Approved’ as per the System and Procedure of Central Pollution Control Board for Emission Compliance Testing of Retro-fit Emission Control Devices (RECD) For Diesel Power Generating Set Engines, Dated 01/02/2022, wide Pollution Control Series PCLS/12/2021-22 Adhering to this, RECD to be ‘Type Approved’ for equivalent kVA rating from any one of the four Central Pollution Control Board, Govt, of India, recognized/approved test agencies / laboratories as given below: (a) Automotive Research Association of India (ARAI, Pune) (b) International Centre for Automotive Testing (ICAT, Manesar) RECD should not be consumed additional electricity / power either from main supply or DG set to operate. No extra electricity or power would be provided to run the RECD. RECD to be installed on the top of the DG set, with available space. No extra space to install RECD will be provided around DG set considering constraint of the space and its coast. The system must be constructed by weather proof stainless steel housing & have feasibility to show online temperature and pressure monitoring at the controller of the device. The RECD must comply as per DPCC/CPCB guidelines as required at site. |
| 14 | SH: (Others LT PANELs )Supplying, installation, testing & commissioning of cubical type LT panel suitable for indoor/outdoor application with IP42/IP54 (with canopy) protection according to the site requirements,415 V, 3 Phase, 4 Wire 50 Hz AC supply system fabricated in compartmentalized design having bus bar chamber duly fabricated from CRCA sheet steel of 2 mm thick for frame, back, sides, partition & doors and 3mm thick for glad plate duly powder coated in approved shade including cleaning & finishing complete with 7 tank process complete with non extensible type four strip aluminium alloy bus bars of required capacity as per incomer rating, hight conductivity, DMC/ SMC bus bar supports having short circuit withstand capacity of 31 MVA for '1' Sec., bottom base channel of MS section not less than 100 mm x 50 mm x 5 mm thick, entire panel shall have a common earth bar of size 25 mm x 5 mm at the rear with 2 Nos. earth stud, solid connections from main bus bar to switch gears with required size of Al. bus bars, control wiring with 2.5 sq. mm. PVC insulated copper conductor single core cable, cooling / ventilation fans including construction of suitable CC foundation, in & out connections and providing & Fixing following switch gears therein etc. complete as required and as per direction of Engineer-in-Charge. 9.01) ANVESHAN FOUNDATION LT PANEL Incoming(i)1 Nos- 250 Ampers four pole module case circuit breaker of fault breaking capacity 36 kA breaking capacity (Ics = Icu = Icw=100%) for 1 second complete with Microprocessor based release for adjustable setting for over current, earth fault & short circuit protection(ii) 1 Sets- RYB Phase indication LED lamps with 6A, 10KA, \\"C\\" Curve back up MCB, breaker (iii) 1Nos.- 3 phase Intelligent multifunction digital meter to read V, A, KVA, KWH, PF Hz etc. with 3 Nos. resin cast CTs of 250/5 A class 1.0 accuracy and 15 VA burden . Busbars(i) 300A FP aluminium busbarsOutgoing(i) 4 Set- 125A, FP, 36KA MCCB (Ics=Icu =100%) with Thermal based release with adjustable setting having O/L & S/C protection with Rotary handle and spreader terminal. (ii) 4 sets- ON indicating light with 6A, 10KA, \\"C\\" Curve backup MCB, auxiliary contacts with MCCB |
| 15 | 9.02) SSR BLOCK FEEDER PILLARIncoming(i)1 Nos- 630 Ampers four pole module case circuit breaker of fault breaking capacity 36 kA breaking capacity (Ics = Icu = Icw=100%) for 1 second complete with Microprocessor based release for adjustable setting for over current, earth fault & short circuit protection(ii) 1 Sets- RYB Phase indication LED lamps with 6A, 10KA, \\"C\\" Curve back up MCB, breaker (iii) 1Nos.- 3 phase Intelligent multifunction digital meter to read V, A, KVA, KWH, PF Hz etc. with 3 Nos. resin cast CTs of 600/5 A class 1.0 accuracy and 15 VA burden . Busbars(i) 800A FP aluminium busbarsOutgoing(i) 2 Set-400A, FP, 36KA MCCB (Ics=Icu =100%) with Microprocessor based release with adjustable setting having O/L & S/C protection with Rotary handle and spreader terminal. (ii) 4 Set- 250A, FP, 36KA MCCB (Ics=Icu =100%) with Microprocessor based release with adjustable setting having O/L & S/C protection with Rotary handle and spreader terminal.(iii) 2 Set- 125A, FP, 36KA MCCB (Ics=Icu =100%) with Thermal based release with adjustable setting having O/L & S/C protection with Rotary handle and spreader terminal. (iv) 8 sets- ON indicating light with 6A, 10KA, \\"C\\" Curve backup MCB, auxiliary contacts with MCCB |
| 16 | 9.03 ) ELECTRONICS BLOCK EMG LT PANEL Incoming(i)1 Nos- 250 Ampers four pole module case circuit breaker of fault breaking capacity 36 kA breaking capacity (Ics = Icu = Icw=100%) for 1 second complete with Microprocessor based release for adjustable setting for over current, earth fault & short circuit protection(ii) 1 Sets- RYB Phase indication LED lamps with 6A, 10KA, \\"C\\" Curve back up MCB, breaker (iii) 1Nos.- 3 phase Intelligent multifunction digital meter to read V, A, KVA, KWH, PF Hz etc. with 3 Nos. resin cast CTs of 250/5 A class 1.0 accuracy and 15 VA burden.Busbars(i) 300A FP aluminium busbarsOutgoing(i) 8 Set- 100A, FP, 25KA MCCB (Ics=Icu =100%) with Thermal based release with adjustable setting having O/L & S/C protection with Rotary handle and spreader terminal. (ii) 8 sets- ON indicating light with 6A, 10KA, \\"C\\" Curve backup MCB, auxiliary contacts with MCCB |
| 17 | 9.04 ) ELECTRONICS BLOCK NORMAL LT PANELIncoming(i)1 Nos- 400 Ampers four pole module case circuit breaker of fault breaking capacity 36 kA breaking capacity (Ics = Icu = Icw=100%) for 1 second complete with Microprocessor based release for adjustable setting for over current, earth fault & short circuit protection(ii) 1 Sets- RYB Phase indication LED lamps with 6A, 10KA, \\"C\\" Curve back up MCB, breaker (iii) 1Nos.- 3 phase Intelligent multifunction digital meter to read V, A, KVA, KWH, PF Hz etc. with 3 Nos. resin cast CTs of 400/5 A class 1.0 accuracy and 15 VA burden . Busbars(i) 500A FP aluminium busbarsOutgoing(i) 4 Sets- 250A, FP, 36KA MCCB (Ics=Icu =100%) with Microprocessor based release with adjustable setting having O/L & S/C protection with Rotary handle and spreader terminal. (ii) 4 Sets- 100A, FP, 25KA MCCB (Ics=Icu =100%) with Thermal based release with adjustable setting having O/L & S/C protection with Rotary handle and spreader terminal. (iii) 8 sets- ON indicating light with 6A, 10KA, \\"C\\" Curve backup MCB, auxiliary contacts with MCCB |
| 18 | 9.05 ) ADMIN BLOCK FF FLOOR EMG & NORMAL PANELIncoming(i)1 Nos- 250 Ampers four pole module case circuit breaker of fault breaking capacity 36 kA breaking capacity (Ics = Icu = Icw=100%) for 1 second complete with Microprocessor based release for adjustable setting for over current, earth fault & short circuit protection(ii) 1 Sets- RYB Phase indication LED lamps with 6A, 10KA, \\"C\\" Curve back up MCB, breaker (iii) 1Nos.- 3 phase Intelligent multifunction digital meter to read V, A, KVA, KWH, PF Hz etc. with 3 Nos. resin cast CTs of 250/5 A class 1.0 accuracy and 15 VA burden . Busbars(i) 300A FP aluminium busbarsOutgoing(i) 6 Set- 125A, FP, 36KA MCCB (Ics=Icu =100%) with Thermal based release with adjustable setting having O/L & S/C protection with Rotary handle and spreader terminal. (ii) 6 sets- ON indicating light with 6A, 10KA, \\"C\\" Curve backup MCB, auxiliary contacts with MCCB |
| 19 | 9.06 ) MECH LAB NORMAL LT PANELIncoming(i)1 Nos- 630 Ampers four pole module case circuit breaker of fault breaking capacity 36 kA breaking capacity (Ics = Icu = Icw=100%) for 1 second complete with Microprocessor based release for adjustable setting for over current, earth fault & short circuit protection(ii) 1 Sets- RYB Phase indication LED lamps with 6A, 10KA, \\"C\\" Curve back up MCB, breaker (iii) 1Nos.- 3 phase Intelligent multifunction digital meter to read V, A, KVA, KWH, PF Hz etc. with 3 Nos. resin cast CTs of 600/5 A class 1.0 accuracy and 15 VA burden . Busbars(i) 800A FP aluminium busbarsOutgoing(i)4 Set- 250A, FP, 36KA MCCB (Ics=Icu =100%) with Microprocessor based release with adjustable setting having O/L & S/C protection with Rotary handle and spreader terminal. (Ii) 4 Set- 200A, FP, 36KA MCCB (Ics=Icu =100%) with Thermal based release with adjustable setting having O/L & S/C protection with Rotary handle and spreader terminal. (ii) 8 sets- ON indicating light with 6A, 10KA, \\"C\\" Curve backup MCB, auxiliary contacts with MCCB |
| 20 | 9.07) ADMIN BLOCK GF EMG PANELIncoming(i)1 Nos- 400 Ampers four pole module case circuit breaker of fault breaking capacity 36 kA breaking capacity (Ics = Icu = Icw=100%) for 1 second complete with Microprocessor based release for adjustable setting for over current, earth fault & short circuit protection(ii) 1 Sets- RYB Phase indication LED lamps with 6A, 10KA, \\"C\\" Curve back up MCB, breaker (iii) 1Nos.- 3 phase Intelligent multifunction digital meter to read V, A, KVA, KWH, PF Hz etc. with 3 Nos. resin cast CTs of 400/5 A class 1.0 accuracy and 15 VA burden . Busbars(i) 500A FP aluminium busbarsOutgoing(i)4 Set- 250A, FP, 36KA MCCB (Ics=Icu =100%) with thermal based release with adjustable setting having O/L & S/C protection with Rotary handle and spreader terminal.(Ii) 4 Set- 200A, FP, 36KA MCCB (Ics=Icu =100%) with Thermal based release with adjustable setting having O/L & S/C protection with Rotary handle and spreader terminal. (ii) 8 sets- ON indicating light with 6A, 10KA, \\"C\\" Curve backup MCB, auxiliary contacts with MCCB |
| 21 | 9.08) ADMIN BLOCK PUMP HOUSEIncoming(i)1 Nos- 125 Ampers four pole module case circuit breaker of fault breaking capacity 36 kA breaking capacity (Ics = Icu = Icw=100%) for 1 second complete with thermal based release for adjustable setting for over current, (ii) 1 Sets- RYB Phase indication LED lamps with 6A, 10KA, \\"C\\" Curve back up MCB, breaker (iii) 1Nos.- 3 phase Intelligent multifunction digital meter to read V, A, KVA, KWH, PF Hz etc. with 3 Nos. resin cast CTs of 150/5 A class 1.0 accuracy and 15 VA burden . Busbars(i) 150A FP aluminium busbarsOutgoing(i)4 Set- 10hp dol starter with o/l relay contactor,push button,on/trip indication,spp.(ii) 1 Set- 63A, FP, 25KA MCCB (Ics=Icu =100%) with Thermal based release with adjustable setting having O/L & S/C protection with Rotary handle and spreader terminal. (iii) 1 sets- ON indicating light with 6A, 10KA, \\"C\\" Curve backup MCB, auxiliary contacts with MCCB |
| 22 | 9.09) MAIN GATE PUMP LT PANELIncoming(i)1 Nos- 250 Ampers four pole module case circuit breaker of fault breaking capacity 36 kA breaking capacity (Ics = Icu = Icw=100%) for 1 second complete with Microprocessor based release for adjustable setting for over current, earth fault & short circuit protection(ii) 1 Sets- RYB Phase indication LED lamps with 6A, 10KA, \\"C\\" Curve back up MCB, breaker (iii) 1Nos.- 3 phase Intelligent multifunction digital meter to read V, A, KVA, KWH, PF Hz etc. with 3 Nos. resin cast CTs of 250/5 A class 1.0 accuracy and 15 VA burden . Busbars(i) 300A FP aluminium busbarsOutgoing(i) 6 Set- 10hp dol starter with o/l relay contactor,push button,on/trip indication,spp.(ii) 6 Set- 100A, FP, 25KA MCCB (Ics=Icu =100%) with Thermal based release with adjustable setting having O/L & S/C protection with Rotary handle and spreader terminal. (iii) 6 sets- ON indicating light with 6A, 10KA, \\"C\\" Curve backup MCB, auxiliary contacts with MCCB |
| 23 | 9.10) MAIN GROUND FEEDER PILLARIncoming(i)1 Nos- 250 Ampers four pole module case circuit breaker of fault breaking capacity 36 kA breaking capacity (Ics = Icu = Icw=100%) for 1 second complete with Microprocessor based release for adjustable setting for over current, earth fault & short circuit protectio(ii) 1 Sets- RYB Phase indication LED lamps with 6A, 10KA, \\"C\\" Curve back up MCB, breaker (iii) 1Nos.- 3 phase Intelligent multifunction digital meter to read V, A, KVA, KWH, PF Hz etc. with 3 Nos. resin cast CTs of 250/5 A class 1.0 accuracy and 15 VA burden . Busbars(i) 300A FP aluminium busbarsOutgoing(i) 6 Set- 100A, FP, 25KA MCCB (Ics=Icu =100%) with Thermal based release with adjustable setting having O/L & S/C protection with Rotary handle and spreader terminal. (ii) 6 sets- ON indicating light with 6A, 10KA, \\"C\\" Curve backup MCB, auxiliary contacts with MCCB |
| 24 | 9.11) FEEDER PILLAR 400AIncoming(i)1 Nos- 400 Ampers four pole module case circuit breaker of fault breaking capacity 36 kA breaking capacity (Ics = Icu = Icw=100%) for 1 second complete with Microprocessor based release for adjustable setting for over current, earth fault & short circuit protection(ii) 1 Sets- RYB Phase indication LED lamps with 6A, 10KA, \\"C\\" Curve back up MCB, breaker (iii) 1Nos.- 3 phase Intelligent multifunction digital meter to read V, A, KVA, KWH, PF Hz etc. with 3 Nos. resin cast CTs of 400/5 A class 1.0 accuracy and 15 VA burden . Busbars(i) 500A FP aluminium busbarsOutgoing(i)4 Set- 250A, FP, 36KA MCCB (Ics=Icu =100%) with thermal based release with adjustable setting having O/L & S/C protection with Rotary handle and spreader terminal.(Ii) 4 Set- 200A, FP, 36KA MCCB (Ics=Icu =100%) with Thermal based release with adjustable setting having O/L & S/C protection with Rotary handle and spreader terminal. (ii) 8 sets- ON indicating light with 6A, 10KA, \\"C\\" Curve backup MCB, auxiliary contacts with MCCB |
| 25 | 9.12) FEEDER PILLAR 250AIncoming(i)1 Nos- 250 Ampers four pole module case circuit breaker of fault breaking capacity 36 kA breaking capacity (Ics = Icu = Icw=100%) for 1 second complete with Microprocessor based release for adjustable setting for over current, earth fault & short circuit protectio(ii) 1 Sets- RYB Phase indication LED lamps with 6A, 10KA, \\"C\\" Curve back up MCB, breaker (iii) 1Nos.- 3 phase Intelligent multifunction digital meter to read V, A, KVA, KWH, PF Hz etc. with 3 Nos. resin cast CTs of 250/5 A class 1.0 accuracy and 15 VA burden . Busbars(i) 300A FP aluminium busbarsOutgoing(i) 6 Set- 125A, FP, 36KA MCCB (Ics=Icu =100%) with Thermal based release with adjustable setting having O/L & S/C protection with Rotary handle and spreader terminal. (ii) 6 sets- ON indicating light with 6A, 10KA, \\"C\\" Curve backup MCB, auxiliary contacts with MCCB |
| 26 | 9.13) ADMIN BLOCK GF FLOOR EMG & NORMAL PANELIncoming(i)1 Nos- 250 Ampers four pole module case circuit breaker of fault breaking capacity 36 kA breaking capacity (Ics = Icu = Icw=100%) for 1 second complete with Microprocessor based release for adjustable setting for over current, earth fault & short circuit protection(ii) 1 Sets- RYB Phase indication LED lamps with 6A, 10KA, \\"C\\" Curve back up MCB, breaker (iii) 1Nos.- 3 phase Intelligent multifunction digital meter to read V, A, KVA, KWH, PF Hz etc. with 3 Nos. resin cast CTs of 250/5 A class 1.0 accuracy and 15 VA burden . Busbars(i) 300 A FP aluminium busbarsOutgoing(i) 6 Set- 125A, FP, 36KA MCCB (Ics=Icu =100%) with Thermal based release with adjustable setting having O/L & S/C protection with Rotary handle and spreader terminal. (ii) 6 sets- ON indicating light with 6A, 10KA, \\"C\\" Curve backup MCB, auxiliary contacts with MCCB |
| 27 | 9.14) ADMIN BLOCK BACK SIDE PANEL(i)1 Nos- 250 Ampers four pole module case circuit breaker of fault breaking capacity 36 kA breaking capacity (Ics = Icu = Icw=100%) for 1 second complete with Microprocessor based release for adjustable setting for over current, earth fault & short circuit protection(ii) 1 Sets- RYB Phase indication LED lamps with 6A, 10KA, \\"C\\" Curve back up MCB, breaker (iii) 1Nos.- 3 phase Intelligent multifunction digital meter to read V, A, KVA, KWH, PF Hz etc. with 3 Nos. resin cast CTs of 250/5 A class 1.0 accuracy and 15 VA burden . Busbars(i) 300 A FP aluminium busbarsOutgoing(i) 6 Set- 125A, FP, 36KA MCCB (Ics=Icu =100%) with Thermal based release with adjustable setting having O/L & S/C protection with Rotary handle and spreader terminal. (ii) 6 sets- ON indicating light with 6A, 10KA, \\"C\\" Curve backup MCB, auxiliary contacts with MCCB |
| 28 | 9.15) Machine Work Shop Panel(i)1 Nos- 250 Ampers four pole module case circuit breaker of fault breaking capacity 36 kA breaking capacity (Ics = Icu = Icw=100%) for 1 second complete with Microprocessor based release for adjustable setting for over current, earth fault & short circuit protection(ii) 1 Sets- RYB Phase indication LED lamps with 6A, 10KA, \\"C\\" Curve back up MCB, breaker (iii) 1Nos.- 3 phase Intelligent multifunction digital meter to read V, A, KVA, KWH, PF Hz etc. with 3 Nos. resin cast CTs of 250/5 A class 1.0 accuracy and 15 VA burden . Busbars(i) 300 A FP aluminium busbarsOutgoing(i) 6 Set- 125A, FP, 36KA MCCB (Ics=Icu =100%) with Thermal based release with adjustable setting having O/L & S/C protection with Rotary handle and spreader terminal. (ii) 6 sets- ON indicating light with 6A, 10KA, \\"C\\" Curve backup MCB, auxiliary contacts with MCCB |
| 29 | 9.16) ADMIN BLOCK NORMAL LT PANEL G FLOORIncoming(i)1 Nos- 630 Ampers four pole module case circuit breaker of fault breaking capacity 36 kA breaking capacity (Ics = Icu = Icw=100%) for 1 second complete with Microprocessor based release for adjustable setting for over current, earth fault & short circuit protection(ii) 1 Sets- RYB Phase indication LED lamps with 6A, 10KA, \\"C\\" Curve back up MCB, breaker (iii) 1Nos.- 3 phase Intelligent multifunction digital meter to read V, A, KVA, KWH, PF Hz etc. with 3 Nos. resin cast CTs of 600/5 A class 1.0 accuracy and 15 VA burden . Busbars(i) 800A FP aluminium busbarsOutgoing(i)4 Set- 250A, FP, 36KA MCCB (Ics=Icu =100%) with Microprocessor based release with adjustable setting having O/L & S/C protection with Rotary handle and spreader terminal. (Ii) 4 Set- 200A, FP, 36KA MCCB (Ics=Icu =100%) with Thermal based release with adjustable setting having O/L & S/C protection with Rotary handle and spreader terminal. (ii) 8 sets- ON indicating light with 6A, 10KA, \\"C\\" Curve backup MCB, auxiliary contacts with MCCB |
| 30 | 9.17 ) Mechanical Block Near Staircase Normal PanelIncoming(i)1 Nos- 400 Ampers four pole module case circuit breaker of fault breaking capacity 36 kA breaking capacity (Ics = Icu = Icw=100%) for 1 second complete with Microprocessor based release for adjustable setting for over current, earth fault & short circuit protection(ii) 1 Sets- RYB Phase indication LED lamps with 6A, 10KA, \\"C\\" Curve back up MCB, breaker (iii) 1Nos.- 3 phase Intelligent multifunction digital meter to read V, A, KVA, KWH, PF Hz etc. with 3 Nos. resin cast CTs of 400/5 A class 1.0 accuracy and 15 VA burden . Busbars(i) 500A FP aluminium busbarsOutgoing(i)4 Set- 250A, FP, 36KA MCCB (Ics=Icu =100%) with thermal based release with adjustable setting having O/L & S/C protection with Rotary handle and spreader terminal.(Ii) 4 Set- 200A, FP, 36KA MCCB (Ics=Icu =100%) with Thermal based release with adjustable setting having O/L & S/C protection with Rotary handle and spreader terminal. (ii) 8 sets- ON indicating light with 6A, 10KA, \\"C\\" Curve backup MCB, auxiliary contacts with MCCB |
| 31 | 10) SH: (EI Work)Providing and laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc including form work etc as required |
| 32 | 11 ) Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal/ coke and salt as required. |
| 33 | 12) Earthing with G.I. earth pipe 4.5 Meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/coke and salt as required. |
| 34 | 13 ) Supplying and laying 25 mm X 5 mm copper strip at 0.50 meter below ground as strip earth electrode, including connection/terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50 mm) |
| 35 | 14) Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm |
| 36 | 15) Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. |
| 37 | 16) Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required. |
| 38 | 17) Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.a) 3.5X 35 Sq.mm (32mm) |
| 39 | b) 3.5 X 50 Sq.mm (35mm) |
| 40 | c) 3.5X 95 Sq.mm (45mm) |
| 41 | d) 3.5 X 120 Sq.mm (45mm) |
| 42 | e)3.5X 300 Sq.mm (70 mm) |
| 43 | f) 3.5 X 400 sq. mm (82mm) |
| 44 | 18) Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.a) 3.5X 35 Sq.mm |
| 45 | b) 3.5 X 50 Sq.mm |
| 46 | c) 3.5X 95 Sq.mm |
| 47 | d) 3.5 X 120 Sq.mm |
| 48 | e) 3.5X 300 Sq.mm |
| 49 | f) 3½ X 400 sq. Mm |
| 50 | 19) Supplying, laying and fixing of following sizes XLPE insulated PVC sheathed aluminum conductor armoured cable of 1.1 KV grade on surface etc complete as required.a) 3 X 10 Sq.mm |
| 51 | b) 4 X 16 Sq.mm |
| 52 | c) 4 X 25 Sq.mm |
| 53 | d) 3.5 X 35 Sq.mm |
| 54 | e) 3.5 X 70 Sq.mm |
| 55 | f) 3.5 X 120 Sq.mm |
| 56 | g) 3.5 X 300 Sq.mm |
| 57 | h) 3.5 X 400 Sq.mm |
| 58 | i) 3.5 X 50 Sq.mm |
| 59 | 20) Supplying, laying and fixing of following sizes XLPE insulated PVC sheathed Copper conductor armoured cable of 1.1 KV grade on surface etc complete as required.a) 3 X 1.5 Sq.mm |
| 60 | b) 8 X 2.5 Sq.mm |
| 61 | c) 4 X 4 Sq.mm |
| 62 | 21) Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required.21.01) 63 mm dia (OD-63 mm & ID-51 mm nominal) |
| 63 | 21.02) 90 mm dia (OD-90 mm & ID-76 mm nominal) |
| 64 | 21.03) 120 mm dia (OD-120 mm & ID-103 mm nominal) |
| 65 | 22) Dismantling of existing substation equipment and Credit bye back to contractor of old Dismantled material,22.01) HT Panel 630 Amp |
| 66 | 22.02) 1000 KVA Transformer |
| 67 | 22.03) Bus trunking |
| 68 | 22.04) MAIN LT PANEL |
| 69 | 22.05) APFC Pannel |
| 70 | 22.06) Emergency panel |
| 71 | 22.07) Others LT PANEL |
| 72 | 22.08) Other EI Item, MALBA etc. (cable,conductor,lugs,termination,point etc.) Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail