Tender for Repair And Renovation Of Electrical Works For Different Staff Quarter At Paikar Rh Under Murarai Block, R Urhat Hd.

Corrigendum Details

Sr No CorrigendumDate Corrigendum CorrigendumType NewSubmissionDate
1 11-06-2026 Corrie of Fees Fee 23-06-2026

Key Dates

Publish Date 11-06-2026
Last Date of Bid Submission 23-06-2026

Contact Information

Company Name Public Works Department
Contact Person Sr.Superintending Engineer
Address Office of the Sr. Superintending Engineer, Western Electrical Circle , PWD, Purta Bhavan, 1st floor, Burdwan-713103

BOQ Items

Name of Work:- Repair and Renovation of Electrical Works for different staff quarter at Paikar RH under Murarai Block, R urhat HD.
Sl. No. Item Description
1Head - I : Internal Electrical InstallationSupplying and fixing 2 Way MCB SS enclosure with IP-20/30 protection, powder coated provision for four pole MCB, incl. A DP MCB Isolator, concealed/surface in wall after cutting the wall & mending good the damages to original finish incl. painting, connection & provision for earthing attachment. [PWD/GS Page: D-9 Item: 11, D-9 Item: 13] (Make-Legrand) [for each quarters incommer]
2Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required. 2 x 10 sq mm + 1X 6 sqmm [from meter to DP encloser] [PWD/GS Page:E-9 Item: 1/(b1)
3Supplying & fixing sheet metal (16 SWG)[500x150mm] Iron Clad Al Busbar chambers on angle iron frame on wall, incl. earthing attachment and painting as required – ( As per Drawing no. 470 of PWD Specification Book – May 1991) 415 V, 63 A Al Bus Bar (2 x 20x5mm) [PWD/GS Page: D-12 Item: 19/b ]
4S&F 2+16 way double-door SPN MCB Distribution Board with IP-42/43 protection, with 240 V 40 A DP MCB isolator as incomer and 16 nos. 6-32A SPMCB as outgoing, concealed in wall after cutting the wall/on angle iron frame on wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment.as per GS (Make -Legrand/Havells/ ABB/L&T /Seimens) [PWD/GS Page: D-9 Item: 13, Page: D-5 Item: 6 & 7] [SPN for EI/Power Plug =33]
5Distribution wiring in 2 x 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make), with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Modular type switch (Brand approved by EIC) fixed on Modular GI switch board with top cover plate and 2 no. suitable size “Ph & N” copper bar & earthing attachment fixed on wall incl. mending good damages to original finish. Average run 6 mtr [PWD/GS Page: E - 24 Item: 1/(b) ]
6Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to 240 V 6A 5 pin plug point incl. S&F 240 V 6A 3 pin Modular type plug socket & Modular type switch (Brand approved by EIC) incl. S&F earth continuity wire, fixed on 4 Module GI switch board with 3/4 Module top cover plate flushed in wall incl. mending good damages to original finis On board [PWD/GS Page: E-20 Item: 3 ]
7Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required. 2x 6 sq mm + 1X 4 sqmm [Busber to SPNDB ] [PWD/GS Page: E-9 Item: 1 ]
8Do…............Do…............2 x 6 sq mm + 1X 4 sqmm [For Pump ]
9Do………………Do………………..Do………….2 x 4 sq mm + 1X 2.5 [For AC and gyeser]
10Do……Do…..Do…2 x 2.5 sq mm + 1X 1.5 [For Power Socket/ Computer Board]
11Do…………………..Do…………………Do……………...3 x 1.5 sq mm [separate 2x6A plug points]
12Finishing of the PVC insulated wire ends by socketting with pin/ring type copper sockets and insulated tapes etc., including supplying sockets, tapes 2x 10 sq mm + 1X 4 sqmm [PWD/GS Page: F-5 Item: 9 ]
13Do…...................Do…................2x 6 sq mm + 1X 4 sqmm
14Do…...................Do…................ 2x4 sq mm + 1X 2.5sqmm
15Do………………Do………………..Do………….2 x 2.5 sq mm + 1X 1.5 sq mm
16Do…………………..Do…………………Do……………...3 x 1.5 sq mm
17Supplying and fixing 20 mm PVC Rigid Conduit 'FR' [Precision Make] on wall, ceiling with saddles and other accessories as required and mending good damages to building works. [PWD/GS Page: E-16 Item: 7/a ]
18Supply & Fixing 240 V, 3 nos. 6 A, 3 pin Modular type plug socket & 1 nos. 6/16 A, 3 pin Modular type plug socket with 3 nos. 6A Modular type switch & 1 nos. 6/16 A, 3 pin Modular type switch (Brand approved by EIC), without plug top on 2 row 12 Module GI Modular type switch board with 2 row 12 Module top cover plate flushed in wall/on wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.[PWD/GS Page: E-17 Item: 1, 3, 4]
19Supply & Fixing 240 V, 2 nos. 6 A, 5 pin Modular type plug socket (Brand approved by EIC) with separate 2 nos. 6A Modular type switch, without plug top on 6 Module GI Modular type switch board with 6 Module top cover plate flushed in wall/on wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc [PWD/GS Page: E-17 Item: 1, 3, 4]
20Supply & Fixing 240 V, 1 nos. 6 A, 3 pin Modular type plug socket & 1 nos. 6/16 A, 5 pin Modular type plug socket (Brand approved by EIC) with separate 1 nos. 6A Modular type switch & 1 nos. 6/16 A Modular type switch, without plug top on 6 Module GI Modular type switch board with 6 Module top cover plate flushed in wall/on wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. [PWD/GS Page: E-17 Item: 1, 3, 4]
21Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket (Brand approved by EIC), without plug top and switch with 2 Module GI Modular type switch board with top cover plate flushed in wall and making necy. connections with PVC Cu wire and earth continuity wire etc. [For AC ] [PWD/GS Page: E-17 Item: 5a]
22Supply & Fixing 240 V, 25 A, Modular type starter (Brand approved by EIC) with 25A Modular switch type DP MCB (CCurve) and 4 Module GI Modular type switch board with 4 Module top cover plate flushed/ in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc [PWD/GS Page: E-19 Item: 17]
23Supply & Fixing 240 V,25 A, 3 pin Modular type plug top with indicator (Brand approved by EIC) & necy. Connections. [For AC] [PWD/GS Page: E-17 Item: 5b]
24Supply & Fixing 240V, Modular Socket (2 Module) type fan regulator (Step type) (Brand approved by EIC) on existing Modular GI switch board with top cover plate incl. making necy. connections etc. [PWD/GS Page: E-18 Item: 10]
25Head - II : Installation of Building Pheripheral Light.S&F Timer Control Unit for single phase AC Machine assembled with - 8-way SPN DB Box (L&T / Cabtree/Legrand/Siemens/ABB) - 1 no. 32 A DP MCB Isolator (Make: Siemense / Legrand / L&T) - 01 no. Digital 24 hour time switch (GIC/L&T) - 1 no.32A three pole contactor (L&T) - 01 no. Centre off 2 way toggle switch - 1 no.32Amp. Barirrer type terminal- 1 no.LED indicating lamp (L&T: SIL R 240V) - 01 No.2X4sqmm+2.5sqmm copper wire 0.5 Mtr. with complete interconnection with auto-mannual bypass arrangement with locking arrangement incl. making/cutting door of SPN DB box for fixing arrangement of toggle switch, Locking arrangement, LED indicator etc. as required as per direction of EIC. [ For security Light - 1]
26Supply & Delivery of following size PVC insulated sheathed Al / XLPE armoured power cable of 1.1 KV grade. [Make : Gloster/ Polycab / RR] 2 Core x 6 sq.mm [ From busber to Securty Light ]
27Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below 2 Core x 6 sq.mm [PWD/GS Page: F-4 Item: 7/c ]
28Finishing of the XLPE/PVC insulated armoured cable ends by soldering with cable sockets and insulated tapes etc., including supplying sockets, soldering materials, tapes etc. and making connection to switch, BDB and BBC etc. 2 Core x 6 sq.mm [PWD/GS Page: F-5 Item: 8/b ]
29Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required. 2 x 1.5 sq mm + 1X 1.5 sqmm [For Securty Light] [PWD/GS Page: E-9 Item: 1 ]
30Finishing of the PVC insulated wire ends by socketting with pin/ring type copper sockets and insulated tapes etc., including supplying sockets, tapes 2 x 1.5 sq mm + 1X 1.5 sqmm [PWD/GS Page: F-5 Item: 9 ]
31Supplying and fixing 20 mm PVC Rigid Conduit 'FR' [Precision Make] on wall, ceiling with saddles and other accessories as required and mending good damages to building works. [PWD/GS Page: E-16 Item: 7/a ]
32Supply & Fixing 240 V, 45 W, 100 Lm/W only outdoor / street light type fitting complete with all accessories to be fixed / projected from the wall of the building incl. making holes/providing clamping arrangement & necy. GI reducer as required. S&F 40 mm GI pipe (ISI-Medium) quality 1.5 mts. average length having suitable bend S&F necy. length of 1.5 sqmm PVC insulated single core stranded annealed copper wire and making connections as required and mending good damages to wall incl. painting etc. [Make- Havells/ Wipro/ Crompton/Bajaj] [Supply of light - Non-Schedule Item, Fixing of Light - PWD/GS Page: C-2 Item: 13 ] (With 5 years Warrenty)
33Supplying & Fixing GI waterproof type looping cable box size 200x150x100 mm deep having 4 mm thick comprising of one 250 V 15 A kit-kat fuse unit, one NL on porcelain insulator, one compression type brass cable gland for upto 2- core 16 sqmm PVC/A cable and having lined with rubber gasketted GI top cover with brass machine screws etc., earthing terminal with lug, on steel tubular pole near base, including S&F 40x6 mm thick, MS clamps with bolts, nuts etc. including painting with anticorrosive paint. [PWD/GS Page: H-5 Item: H/5]
34Earthing Installation – with Pipe Electrode :Excavation of soil for installation of Earth Electrode and filling & ramming. For Soft Soil [PWD/GS Page: G-1 Item: 1]
35Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts.long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm diax 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below: By TATA-Medium GI pipe [PWD/GS Page: G-1 Item: 2/a] [ 2 nos. for EI, 2 nos. for Feeder Pillar, 9 nos. for Street Light Pole, ]
36Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos.12 mm dia holes on the GI pipe. [PWD/GS Page: G-2 Item: 3/a]
37Earth BusbarSupplying & fixing earth busbar of galvanized (Hot Dip) MS flat 50 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required. [PWD/GS Page: G-2 Item: 4/c]
38Earth Continuity StripConnecting the equipments to earth busbar including S & F 20 mm x 3 mm Galvanised (Hot Dip) MS Flat on wall / floor with GI saddles as required and connection to equipments with incl. drilling holes, bolts, nuts, washers etc. [PWD/GS Page: G-3 Item: 5/c] Please Enable Macros to View BoQ information

Other Detail

Information Source https://tenders.wb.gov.in/nicgep/app
Download FileName File Description File Size
Download BOQ_5083754.xls Tender Documents 0 KB
Download dc2660ac-bb80-4ed2-a102-c03ea850d93f.html Tender Documents 0 KB
Download new2911.pdf Tender Documents 0 KB
Download Tendernotice_1 (12).pdf Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.