| 1 | 11 Mtrs. Steel lattice structure of 65x65x6mm M.S Angle complete with nuts & bolts conforming to specification of design detail No. LlLlFIIE&PDl11 Mtrs. With Arms |
| 2 | INSULATORS & HARDWARES CONFORMING TO lS:731 11 KV Disc lnsulator 90 KN T/C Type (Porcelain/Polymer) |
| 3 | INSULATORS & HARDWARES CONFORMING TO lS:731 11 KV Pin lnsulator with G.l Pin & fittings as required(Porcelain/Polymer) |
| 4 | STAY SET & Gl WIRES CONFORMING TO 15:1367 PART-3 Gl Wire 8 SWG |
| 5 | A.C.S.R CONDUCTORS CONFORMING TO 1S: 398 PART 2 DOG Conductor 100 sqm, 6/4.72+7 /1.57 |
| 6 | A.C.S.R CONDUCTORS CONFORMING TO 1S: 398 PART 2 WEASEL Conductor 30 sqmm, 6/2.59+1/2.59 |
| 7 | COMPTETE HARDWARE FITTINGS FOR 11 KV DISC INSULATOR TYPE CONFORMING TO lS:731SUITABLE FOR : DOG Conductor |
| 8 | COMPTETE HARDWARE FITTINGS FOR 11 KV DISC INSULATOR TYPE CONFORMING TO lS:731SUITABLE FOR : WEASEL Conductor |
| 9 | Errection of Metalic Pole of following length in cement concreate 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40mm nominal size ) foundation including excavation and refilling etc as required. Above 8 meter and upto 11 meter. |
| 10 | Errection of LV/MV Shackle/Pin/Disc insulator etc as required |
| 11 | Errection of GI Wire No-8 SWG including binding etc as required. |
| 12 | Errection of ACSR Conductor of 7/3.35mm to 7/4.00mm diameter and above including binding etc as required. |
| 13 | Errection of ACSR Conductor of 7/2.11mm to 7/3.00mm diameter including binding etc as required. |
| 14 | Supplying and Errection of stay set complete(galvanised) with 19/20 mm dia x 1.8 meters long stay rod,, anchor plate of size 45cm x45cmx7.5 mm, thimble, stay clamps, turn buckle (20mm x 60 cm), 7/4.00mm dia GI stay wire and strain insulator etc in cement concreate 1:3:6 ( cement: 3 coarse sand : 6 graded stone aggregate 40mm nominal size) foundation including excation and refilling etc as required. |
| 15 | Dismantling of pole/street light standard/strut embedded in cement concrete foundation etc as required. |
| 16 | Dismantling of overhead lines comprising of copper/aluminium overhead conductor, GI wire, cross arms, insulator etc as required. |
| 17 | Earth work in excavation by Mechanical means(Hydrolic excavator)/manual means in foundation trenches or drains (not exceding 1.5m in width or 10sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50m. All kind of Soil. |
| 18 | Centering and Shuttering including strutting, proping etc and removal of form for Foundation, footing, bases of coloum etc for mass concreate. |
| 19 | Providing and laying in position cement concreate of specified grade excluding the cost of centering and shuttering all work upto plinth level.1:3:6 (1 Cement : 3 coarse sand derived from natural sources : 6 graded stone aggregate 40mm nominal size derived from natural sources. Please Enable Macros to View BoQ information |