| 1 | Providing and fixing vinyl flooring/PVC plank flooring having 2 mm thickness over existing tile flooring of approved make and specifications as per the direction of Engineer-in-Charge. This includes preparing surface to receive vinyl flooring/PVC plank flooring requirements like the floor to be levelled, hard, dried, even, and free from dirt, grease, moisture, and fixed using required adhesives, etc complete in all aspects. |
| 2 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm |
| 3 | Providing and laying 1st quality Ceramic glazed anti-skid floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete. |
| 4 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 5 | Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main “T” runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross “T” of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main “T” at 600 mm center to center to form a grid of 1200x600 mm and secondary cross “T” of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main “T” runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. 12.5 mm thick fully Perforated Gypsum Board tile made from plasterboard having glass fibre conforming to IS: 2095 part I, of size 595x595 mm, having perforation of 9.7x9.7 mm at 19.4 mm c/c with center borders of 48 mm and the side borders of 30 mm, backed with non woven tissue on the back side, having an NRC (Noise Reduction Coefficient) of 0.79, with 50 mm resin bonded glass wool backing. |
| 6 | Providing and applying white cement based putty of average thickness 1 mm of approved brand and manufacturer, over plastered surface to prepare the surface even andsmooth complete. |
| 7 | Wall Painting with Finishing with premium plastic emulsion interior paint with low VOC system for interiors using Primer as per manufacturers specifications : Two or more coats applied on walls & ceiling |
| 8 | Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : (a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours. (b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. (a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours. (b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. |
| 9 | Painting with synthetic enamel paint on steel work of approved brand and manufacturer of required colour to give an even shade: one or more coats on old work |
| 10 | Supplying and fixing Roller Blinds to the following specifications , Fabric shade as approved, sunscreen, dense basket weave 5 % openness factor. Operation: - Manual. Offset side- mounted metal chain operated Mounting: Pocket mounted. Shade Orientation: Regular roll, shade cloth falls at window side of roller. Configuration: Single band AVERAGE LENGTH OF BLIND is 2.0 M to 2.5 M. The fabric to be Fire Retardent certified. |
| 11 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. In cement mortar |
| 12 | Dismantling tile/stone work in floors/walls and roofs laid in cement mortar including stacking material within 50 metres lead. For thickness of tiles/stone 10 mm to 25 mm |
| 13 | Dismantling G.I. pipes (external work) including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means including stacking of pipes within 50metres lead as per direction of Engineer-in-charge : 15 mm to 40 mm nominal bore |
| 14 | Dismantling of flushing cistern of all types (C.I./PVC/Vitrious China) including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead. |
| 15 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. |
| 16 | Disposal of moorum/building rubbish/ malba/ similar unserviceable, dismantled or waste material by mechanical transport including loading, transporting, unloading to approved municipal dumping ground for lead upto 10 km for all lifts, complete as per directions of Engineer-in-charge. Note - item to be applicable in urban areas having directions for restricted hours for movement/ plying of load carrying motor vehicle of 3.5 cum or more. |
| 17 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement: 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). |
| 18 | Centering and shuttering including strutting, propping etc. and removal of form for: Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 19 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 20 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level upto V level. cement mortar 1:4 (1 cement : 4 coarse sand). |
| 21 | Extra for providing and placing 2 nos. 6mm dia MS bars at every third course of half brick masonry. |
| 22 | 12 mm cement plaster : 1:4 (1 cement : 4 fine sand) |
| 23 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels. Granite stone slab colour black, Cherry/Ruby red. Area of slab over 0.50 sqm |
| 24 | Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. Granite work |
| 25 | Poviding and fixing partition upto ceiling height consisting of G.I. frame and required board, including providing and fixing of frame work made of special section power pressed/ roll form G.I. sheet with zinc coating of 120 gms/sqm(both side inclusive), consisting of floor and ceiling channel 50mm wide having equal flanges of 32 mm and 0.50 mm thick, fixed to the floor and ceiling at the spacing of 610 mm centre to centre with dash fastener of 12.5 mm dia meter 50 mm length or suitable anchor fastener or metal screws with nylon plugs and the studs 48 mm wide having one flange of 34 mm and other flange 36 mm and 0.50 mm thick fixed vertically within flanges of floor and ceiling channel and placed at a spacing of 610 mm centre to centre by 6 mm dia bolts and nuts, including fixing of studs along both ends of partition fixed flush to wall with suitable anchor fastener or metal screws with nylon plugs at spacing of 450 mm centre to centre, and fixing of boards to both side of frame work by 25 mm long dry wall screws on studs, floor and ceiling channels at the spacing of 300 mm centre to centre. The boards are to be fixed to the frame work with joints staggered to avoid through cracks, M.S. fixing channel of 99 mm width (0.9 mm thick having two flanges of 9.5 mm each) to be provided at the horizontal joints of two boards, fixed to the studs using metal to metal flat head screws, including jointing and finishing to a flush finish with recommended jointing compound, jointing tape, angle beads at corners (25 mm x 25 mm x 0.5 mm), joint finisher and two coats of primer suitable for board as per manufacture's specification and direction of engineer in charge all complete. 75mm overall thickness partition with 12.5 mm thick double skin tapered edged plain Gypsum plaster board conforming to IS: 2095: (part I): 2011 (Board with BIS certification marks) |
| 26 | Repairing/stiching the crack in brick wall by cement mortar grouting (1 : 2) including widening the crack on the surface (into V section) cleaning and packing the same with cement mortar (1 : 2) including mixing of repairing chemicals as required and finishing off the surface to match with adjacent surface. The rate will include scaffolding for as required and disposal of all rubbish/malba as directed by engineer-in-charge. |
| 27 | Providing and fixing glazing in aluminium window, ventilator and partitions etc. with EPDM rubber / neoprene gasket etc. complete in all aspects and the directions of engineer-in-charge . With float glass panes of 4.0 mm thickness (weight not less than 10kg/sqm) |
| 28 | Providing and fixing board/sheet/MS tube for ceiling support of approved quality to cover the open space near staircase with necessary nails, installation complete in all aspects, including making frame work for the open space to be covered. |
| 29 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately) including fixing the architrave/moulding around doorframe. Second class teak wood. |
| 30 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws and door accessories including door closer, door lock, door stopper, door buffer complete in all aspects. |
| 31 | Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). |
| 32 | Extra for providing vision panel not exceeding 0.1 sqm in all type of flush doors (cost of glass included) (overall area of door shutter to be measured): Rectangular or square |
| 33 | Polishing in high gloss/matt finish melamine clear polish on wood work in required color/wooden shade texture with following process in the sequence as detailed below: 1. The surface to be polished is rubbed with sand paper 80/120 no. and then with sand paper of 160/180 nos.2. Applying two coats of sealer with spray gun and allowing sufficient drying time for 1st coat and 2nd coat is allowed to dry for 8 to 12 hrs. 3. On drying of sealer coat, wet rubbing with emery cloth of finer grading with ample water to remove excess sealer layer and make the surface further smooth after this wet rubbing, then surface is applied with special grade melamine fillers to fill all the small and big holes/grooves etc. Filler coat to be allowed to dry for 4 to 6 hrs on which again a light wet rubbing is done this surface is further allowed to dry for 12 hrs.4. On this, 1st coat of melamine polish is applied with spray gun using melamine clear polish and melamine thinner in required proportion. This 1st coat is allowed to dry for 24 hrs then this dry surface is again fine wet rubbed smooth, which is further allowed to dry for 12 hrs. The final melamine polish is applied with compressor pressure spray gun using melamine clear polish and melamine thinner mixed in required proportion complete as per direction of Engineer-in-Charge. (Final coat to be done in 1 or 2 layers without gap of time.) |
| 34 | Providing and fixing 12mm thick toughened glass fixed partition in 45mm thick slim profile system in powder coated profile. |
| 35 | 12mm thick toughened glass door including accessories for toughned glass door including floor spring, handle and lock all complete. |
| 36 | Providing & Fixing Frosted Translucent, cast PVC, self-adhesive vinyl, special CRYSTAL-effect film to reproduce Sand-blasting effect on glass with customized designs, thickness of 2 mil (0.05mm) without adhesive (0.8) with adhesive having minimum tensile strength of 3.5 pound/inch at 73 F(0.6 kg/cm at 23 C). Adhesion after 24hrs of installation should be 4 pounds/inch (0.7 kg/cm) on Acrylic, Glass Polycarbonate: MCS warranty of 3yrs (if exposed to direct sunlight) to 15yrs (indoors)Application -DECORATIVE/PRIVACY FILM ON GLASSElectronically/computer plotter cut. Applied on glass and other rigid, clear substrates. (partitions, doors, windows etc.) Available in 5 colours |
| 37 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead. Of area 3 sq. metres and below. |
| 38 | Providing and fixing the NIELIT brand signage board with logo of approved design as per directions of Engineer-in-Charge. |
| 39 | Providing and fixing white vitreous china water closet of required size of approved shape including providing & fixing cistern with flush fitting, of flushing capacity of 10 litres, including seat cover, and cistern fittings, nuts, bolts and gasket etc complete. |
| 40 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430 x 260 x 350 mm size respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required. |
| 41 | Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. |
| 42 | Providing and fixing PVC soil, waste and vent pipes : Size 100 mm dia |
| 43 | Providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete. Size 100 mm dia |
| 44 | Providing and fixing plain bend of required degree. Size 100 mm dia |
| 45 | Providing and fixing double equal plain junction of required degree. Size 100x100x100x100 mm |
| 46 | Providing and fixing single equal plain junction of required degree : Size 100x100x100 mm |
| 47 | Providing and fixing terminal guard PVC. Size 100 mm |
| 48 | Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors : Size 100 mm inlet and 100 mm outlet |
| 49 | Providing and fixing 18-8 S, type- 304, Stainless Steel towel ring round shape 178 mm outside diameter, 162 mm inside diameter minimum distances of 55 mm from wall face with round flange concealed fittings arrangement of approved quality and colour all complete as per manufacturers specification and direction of Engineer-in-charge. |
| 50 | Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snapfittings of approved quality and colour, weighing not less than 105 gms |
| 51 | Providing and fixing CP Brass Hand Shower (Health Faucet) with 1 Meter Long Easy Flex Tube in Chrome Finish and Wall Hook with N.R.V (Back Flow Preventer) including making all connections, fixing to wall with suitable brackets all as per manufacturers specification and direction of Engineer-in-charge. Size 15 mm nominal dia |
| 52 | Providing and fixing 18-8 S, type- 304, stainless steel Tissue Paper Dispenser 345 mm long, 110 mm wide with 455mm high having 600 C-fold or 800 multifold paper towels capacity with loading from bottom including fixing to wall as per manufacturers specification and direction of Engineer-in-charge. |
| 53 | Providing and fixing urinal partition in 12 mm thick compact laminate with SS brackets |
| 54 | Providing and fixing wash basin with C.I brackets, 15 mm C.P. Brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting andmaking good the walls wherever require: White vitreous china wash basin 630 x 450 mm with pair of 15 mm C.P. brass pillar taps. |
| 55 | Providing & fixing C.P brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 with 15 mm nominal bore |
| 56 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. |
| 57 | (a) 20 mm nominal outer dia Pipes |
| 58 | (b) 25 mm nominal outer dia Pipes |
| 59 | Providing and fixing brass stop cock of approved quality : Size 20 mm nominal bore |
| 60 | Providing and fixing uplasticised PVC connection pipe with brass unions. Size: 45 cm length and 20 mm nominal bore. |
| 61 | Providing & fixing chrome plated brass long body bib cock of approved quality conforming to IS standards. Size 15 mm nominal bore |
| 62 | Providing and fixing 600 x 450 mm bevelled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brassscrews and washers complete. |
| 63 | Electrical Work |
| 64 | * Power connections, UPS wiring, distribution boards, extension boards, electrical fittings(Flame Retardant Technology, Premium Copper Quality, Durable & Reliable, Certified Safety Standards, Class 5 Conductor, High Voltage Load capacity & Thermal Protection)* LED lighting (Bright 6500K Cool Daylight, 1350 Lumen, Energy Efficient 15W Design, 275V)Ceiling and wall mounted fans (1200mm BEE Star Rated Energy Efficient Ceiling Fan | Anti-Rust & Long-lasting with 5 Years warranty)* Exhaust fans, ventilation fans (100% copper winding)* Circuit Breakers (25A, 240V), (65A, 240V), Electrical switches, socket outlets, power cables, cable management systems, wiring for electrical appliances, wiring and socket outlets for split ACs, surge protectors, and any other related electrical components and installations required across all areas, including any necessary conduits, junction boxes, electrical enclosures, and incidental items, for attached drawing and scope of work. *Electrical work provision such as wiring, power connections, fittings, socket outlets and any other related electrical components and installations required for ATMP Machines - Die Bonder ( Voltage 220 VAC, 1.3KVA) - Wire Bonder (Voltage 110 VAC ,1.0 KVA) - Molding Machine (208–480 VAC, 3-Phase, 8.5–13 kVA) - Triming and Forming Machine ( 208–480 VAC, 3-Phase,3–8 kVA). *Separate earthing for building and for ATMP machines. |
| 65 | Networking (Wired +Wireless)Switches: Managed gigabit switches with 24 ports (e.g., 7 units switches) + Rack (22U-01 & 6U-04)Specifications: Layer-2 Managed PoE Switch,24 × 10/100/1000 Mbps RJ45,2 × Gigabit SFP Ports,IEEE802.3af/at PoE+8K or Higher802.1Q VLAN,Layer 2/3/4 QoS,ACL, Port Security,DHCP Snooping,STP/RSTP/MSTP, IGMP Snooping,LACP Supported,Web GUI, CLI,SNMP,SSH, Telnet.Structured Cabling: Cat 6 Ethernet cables or higher for 150 nodes, wall-mounted faceplates, and a patch panel in the server room.Wi-Fi Coverage: Dual-band Wi-Fi 6 APs (13 units) deployed for optimal coverage in staff cubicles, classrooms, labs, server room, reception, and meeting rooms.Specifications: Wireless Type - 802.11ax, ac GSM frequencies - 2.4 GHz, 5 GHz.CCTV Setup:IP Cameras: 14 DOM AND 2 BULLET IP CAM 1080p resolution covering classrooms, labs, reception, meeting room, entry/exit points, server room, and staff cubicle area.NVR: 16-channel NVR with 2TB storage for atleast 15 days of footage retention.PoE Switches: Power cameras efficiently. Please Enable Macros to View BoQ information |