| 1 | Repairs to plaster of thickness 12mm to 20 mm in patches of area 2.5 sq. meters and under, including cutting the patch in proper shape raking out joints and preparing and plastering the surface of the walls complete including disposal of rubbish to the dumping ground within 50 meters lead With cement mortar 1:4 (1 cement : 4 fine sand) |
| 2 | Dismantling roofing including ridges, hips valleys and gutters etc., and stacking the material within 50 meters lead of : G.S. Sheet |
| 3 | Demolishing brick work manually/by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 meters lead as per direction of Engineer-in-charge In cement mortar |
| 4 | Demolishing R.C.C. work manually/by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 meters lead as per direction of Engineer-in-charge. |
| 5 | Earth work in excavation by manual means in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed All kinds of soil : 1 meter from cutting edge |
| 6 | Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. |
| 7 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) |
| 8 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). 20% Boulders |
| 9 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth and curing complete |
| 10 | Providing and laying damp-proof Course 50 mm thick with cement concrete 1:2:4 (1cement:2 coarse sand: 4 graded stone aggregate 20 mm nominal size) and curing complete |
| 11 | Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15°,landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto five level including curing but excluding the cost of centring, shuttering, finishing and reinforcement with 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 12 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing inposition and binding all complete upto plinth level .Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 13 | Centering and shuttering including strutting, propping etc. and removal of form for: Foundations, footings, bases of columns etc. for mass concrete. |
| 14 | Centering and shuttering including strutting, propping etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platforms. |
| 15 | Edges of slabs and breaks in floors and walls.Under 20 cm wide |
| 16 | Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in foundation and plinth including curing in : Cement mortar 1:4 ( 1 cement : 4 coarse sand) |
| 17 | Extra for brick work with common burnt clay bricks/cement concrete bricks in superstructure above plinth level upto floor five level |
| 18 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting , hoisting , fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes |
| 19 | Providing and fixing precoated galvanized iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 20 | Providing ridges or hips of width 60cm overall width plain G.S. sheets fixed with polymer coated J. or L hooks, bolts and nuts 8mm dia G.I. limpet and bitumen washers complete. 0.50 mm thick with zinc coating not less than 275 gram/m2 |
| 21 | Extra for straight cutting in reinforced by organic fibres and/or inorganic synthetic fibres cement corrugated, semi corrugated 6 mm thick sheet roofing for making openings of area exceeding 40 square decimeter for chimney stacks, skylights etc. |
| 22 | Providing reinforced by organic fibres and/or inorganic synthetic fibres cement 6 mm thick corrugated sheets (as per IS: 14871) roofing up to any pitch and fixing with polymer coated J, or L hooks, bolts and nuts 8 mm dia. G.I. plain and bitumen washers or with self drilling fastener and EPDM washers etc. complete (excluding the cost of purlins, rafters and trusses), including cutting sheets to size and shape wherever required. |
| 23 | Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works. |
| 24 | 12mm Cement plaster of mix: 1 : 4 ( 1 cement : 4 fine sand) |
| 25 | Providing and applying white cement based putty of specified thickness, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 1mm |
| 26 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade on New work (two or more coats) over and including priming coat with water thinnable cement primer |
| 27 | Finishing walls with acrylic smooth exterior paint of required shade on New work (Two or more coats applied @ 1.67 liter/10sqm over and including priming coat of exterior primer applied @ 2.20kg/10sqm) |
| 28 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia and length (hold fast lugs or with dash fasteners shall be paid for separately): Sal Wood |
| 29 | Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60mm thickness, including hinges jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25mm, or base ties of 1.60mm pressed, mild steel welded or rigidly fixed together by mechanical means, including M.S pressed butt hinges 2.5mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge:Profile B Fixing with adjustable lugs with split end tail to each jamb |
| 30 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc including priming coat with approved steel primer all complete. Fixed to steel windows by welding |
| 31 | Providing and fixing 35 mm thick factory made laminated veneer lumber door shutter conforming to IS : 14616 and TADS 15:2001 (Part B), fixing with butt hinges of required size with necessary screws, all complete as per directions of Engineer- in-charge and panelling with panels of :12 mm thick pre-laminated particle board (decorative lamination on one side and other side balancing lamination) grade-I, medium density flat pressed three layer particle board FPT-I or graded wood particle board FPT-I, IS: 3087 marked, bonded with BWP type synthetic resin adhesive as per IS: 848 and prelaminated conforming to IS: 12823, Grade-I, Type-II marked : |
| 32 | Providing and fixing wire gauze shutters using galvanized M.S. wire gauze of average width for aperture 1.4 mm in both directions with wire of dia. 0.63 mm for doors, windows and clerestory windows with ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws as per direction of Engineer-in-charge : Second class Kail wood 35mm |
| 33 | Providing and fixing fly proof wire gauge to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions all complete.With Galvanized M.S. Wire gauge with wire of dia 0.63 mm With 2nd class teak wood beading 62x19 mm |
| 34 | Providing and fixing glazed shutters for doors, windows and clerestory windows using 4mm thick float glass panes including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws.Second class Kail wood 35mm |
| 35 | Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick. Float glass panes 4 mm thick glass pane (weighing not less than 10 kg/sqm) |
| 36 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade Two or more coats on new work |
| 37 | Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete. 250x10 mm |
| 38 | Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete. : 150x10 mm |
| 39 | Providing and fixing chromium plated brass handles with necessary screws etc. complete : 125 mm |
| 40 | Providing and fixing chromium plated brass handles with necessary screws etc. complete : 100 mm |
| 41 | Providing and fixing aluminum sliding door bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete : 300x16 mm |
| 42 | Providing and fixing IS : 1341 marked M.S. heavy weight - Butt Hinges with necessary screws etc., complete : 100x75x3.50 mm |
| 43 | Renewing glass panes, with wooden fillets wherever necessary :Float glass panes of thickness 4.0 mm (weight not less than |
| 44 | Carpenter engaged for repair of old doors,windows, and refixing them wherever required complete job. |
| 45 | Helper engaged for repair of old doors,windows, and refixing them wherever required complete job. |
| 46 | Welder engaged for repair of old doors,windows, builtup section and refixing them wherever required complete job. |
| 47 | Helper engaged for repair of old doors,windows, built up section and refixing them wherever required complete job. |
| 48 | Labour engaged for cleaning of sheep dipping tank, including removal of sludge, silt, vegetation, waste material, cleaning of walls and floor, disposal of unserviceable material etc as per direction of Engineer in charge.2Nos for3 Days |
| 49 | Tractor Trolley engaged for disposal of unserviceable materials incl loading, unloading all complete job |
| 50 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5 m. |
| 51 | Providing and fixing on wall face un-plasticized Rigid PVC rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10 mm gap for thermal expansion. Single socketed pipes 110 mm diametre |
| 52 | Providing and fixing on wall face un-plasticized - PVC moulded fittings/accessories for un plasticized Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring Coupler 110 mm |
| 53 | Bend 110 mm |
| 54 | Tee 110 mm |
| 55 | Supplying and fixing C.I. cover without frame for manholes: 455x610mm rectangular C.I. cover (light duty) the weight of the cover to be not less than 23 kg. |
| 56 | Rewiring for light point/fan/exhaust fan point / call bell point with f 1.5sq FRLS PVC insulated copper conductor single core cables with 1.5 sqmm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/recessed steel/PVC conduit including dismantling as required. Group A (NSI) |
| 57 | Providing Wire 10 sqmm (NSI) |
| 58 | Providing Wire 4 sqmm (NSI) |
| 59 | Providing Wire 2.5 sqmm (NSI) |
| 60 | Providing Wire 1.0 sqmm (NSI) |
| 61 | Supplying and fixing following way.Three pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as zequired. (But without MCB/RCCB/Isolator) Double Door. A. 4 way (4 + 12), Double door. (NSI) |
| 62 | Supplying and fixing following rating, 240/415 volts, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. a) MCB single pole 6 A to 32 A (NSI) |
| 63 | b) MCB Double pole 63 A (NSI) |
| 64 | Supplying and fixing following modular switch/socket on the existing modular plate & box as required. a) 5/6 A Switch (NSI) |
| 65 | b) 15/16 A Switch (NSI) |
| 66 | c) 3 Pin 5/6 A Socket Outlet (NSI) |
| 67 | d) 6 Pin 15/16 A Socket Outlet (NSI) |
| 68 | Supplying and fixing following modular base & cover plate on the existing modular metal box as required.1 or 2 module (NSI) |
| 69 | Supplying and fixing following modular base & cover plate on the existing modular metal box as required. 3 module (NSI) |
| 70 | Supplying and fixing following modular base & cover plate on the existing modular metal box as required. 4 module (NSI) |
| 71 | Supplying and fixing following modular base & cover plate on the existing modular metal box as required. 6 module (NSI) |
| 72 | Supplying and fixing following modular base & cover plate on the existing modular metal box as required.8 module (NSI) |
| 73 | Supplying and fixing following modular base & cover plate on the existing modular metal box as required.12 module |
| 74 | Supplying and fixing following modular GI Box in recess as required. 1 or 2 module (NSI) |
| 75 | Supplying and fixing following modular GI Box in recess as required. 3 module (NSI) |
| 76 | Supplying and fixing following modular GI Box in recess as required. 4 module (NSI) |
| 77 | Supplying and fixing following modular GI Box in recess as required. 6 module (NSI) |
| 78 | Supplying and fixing following modular GI Box in recess as required. 8 module (NSI) |
| 79 | Supplying and fixing following modular GI Box in recess as required. 12 module (NSI) |
| 80 | Supply installation testing and commissioning of BLDC Ceiling Fan 1200 mm 230V 28 W with Speed RPM 350 with minimum Air delivery 220 CMM including wiring the down rods of standard length(Upto 30 cm) with 1.5 sq.mm FR PVC insulated,copper conductor,single core cable including providing and fixing phenolic laminated sheet cover on the Fan Box etc as Required.(NSI) |
| 81 | Supplying and fixing Modular Fan regulator. (NSI) |
| 82 | Supply installation testing and commissioning of Exhaust Fans with 1.5 sq.mm FR PVC insulated,copper conductor,single core cable including providing and fixing phenolic laminated sheet cover on the Fan Box etc as Required.(NSI) |
| 83 | Supply installation testing and commissioning of IP:20 Aluminium Batten 20W-22 W +- 1 W LED Surface Mounted 4 ft. with system lumen efficacy of 100 lm/W and P.F >0.9 THD <20% CCT 6500K, CRI 80. The LED should have life of 50000 Burning Hours at L70.The input voltage shall be 150 V to 270 V. The fixture should have inbuilt surge protection of 2KV.Certification-LM 79 and LM 80. (NSI) |
| 84 | Supply installation testing and commissioning of LED Bulbs with holders 14- 20 W with 1.5 sq.mm FR PVC insulated,copper conductor,single core cable including all necessary fittings and accessories. (NSI) |
| 85 | Cement concrete flooring 1:2:4 (1cement: 2 coarse sand: 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry and curing complete, but excluding the cost of nosing of steps etc. complete. 50 mm thick with 20mm nominal size stone aggregate. |
| 86 | Carriage of Sand avg 30 Km by MT |
| 87 | Carriage of Stone Agg avg 30 Km by MT |
| 88 | Carriage of Boulder avg 15 Km by MT |
| 89 | Carriage of Bricks avg 60 Km by MT Please Enable Macros to View BoQ information |