| 1 | Dismantling of wall and ceiling boards fibre pulp insulation etc or insulation boards/slabs/blankets any thickness including cover fillets, complete all as specified and directed. |
| 2 | S&F False ceiling 4 mm thick HPSC pre-prime non asbestos fibre cement building board ( size 600mm x 600 mm/ 595 mm x595 mm ) decorative finish fixed with clips and screw including powder coated galvanised MS grid frame work false ceiling of ( Main Tee size 32mmx20mmx0.45mm cross tee 24mmx24mmx0.30mm and wall angle19x19x0.30 mm ) and with slot for fixing including suspended with1.25 mm dia. GI wire hangers fixed with steel dash through fasteners from purline of the roof complete all as specified and as directed. |
| 3 | S&F In Repairs for E- grid false ceiling 4 mm thick HPSC pre-prime non asbestos fibre cement building board (E-classic size 600mm x 600 mm / 595mm x 595 mm) decorative finish and fixed with from purline of the roof, complete all as specified and directed. |
| 4 | Supply and fixing seamless ceiling with using 12mm thick factory made gysum fibre board fixed with screw , including GI frame work for seamless ceiling comrises of GI erimeter channel 0.55mm thick with two unequal flanges of 20 and 30 mm and web of 27mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre intermediate channel 0.9mm thick having two equal flanges of 15mm each and web of 15mm each and web of 45mm suspended from soffit at approx 900mm centre to centre with GI cleat and steel expansion fasterners with and including ceiling section ( not exc 1.2m length) of 0.55mm thickness having kurled web of 50mm and flange of 26mm with lis of 10.5 mm and fixed to the intermediate channel with connecting clis across the intermediate channel at 457mm centre to centre suitable for suspended system with and including two coat of oil bound distemper over one coat of putty to give even and smooth finish without showing any joints complete all as specified and directed. |
| 5 | Dismantling of AC (corrugated / semi-corrugated) sheets in roof covering including any type of ridges complete all as specified and as directed. |
| 6 | S&F Pre painted galvalum sheet 0.50 mm thick having aluminum zinc coating 150 gsm/ sqm corrugated steel sheet any colour having tensile strength of 550 Mpa as in Roof covering /cladding to wall fixed with self tapping screws complete all as directed by Engineer -in -charge. |
| 7 | S&F Pre painted galvalum sheet 0.50 mm thick having aluminum zinc coating 150 gsm/ sqm plain steel sheet any colour having tensile strength of 550 Mpa as in Roof covering /cladding (ridge) to wall fixed with self tapping screws complete all as directed . |
| 8 | Dismantling timber scantling , framed /un framed work of 40 sq. cm and over in section in any position complete as directed. |
| 9 | M and L for Second class hard-wood (SAL wood) in scantlings, wrought timber frame and fixed in position (As a truss member or in Rafter in roofing work) etc complete as directed. |
| 10 | M and L for Preparing surfaces of wood and applying wood based paint on new or old, of any description and girth, not otherwise described and treated with Creosote oil. |
| 11 | M&L Hand rails, half round or other stock section or core for wooden hand rail straight portion , drilled and counter sunk for balusters running bars, for doors, balusters, nosing to steps including embedding in concrete and screwing etc. wind ties for roof including securing bolts; posts and struts in fencing post including cutting tops to shape as directed, drilling holes, notching for wire , etc.; flat iron fillets ( for securing wire mesh etc. including all necessary drilling , bolting or rivetting , etc., and similar work conforming to Fe 290 Gde E 165 with and including applying two coats of synthetic enamel paint over a coat of primer alround before fixing in position complete all as specified and directed |
| 12 | Dismantling of wrought iron or mild steel work of any description not other wise provided for complete all as specified and as directed. |
| 13 | Dismantling of timber in fillets, rails, posts, rafters, purlins etc under 40 Sq. cm provided for UNFRAMED WORK complete all as specified and as directed. |
| 14 | S&F rolled section as in main and cross beams, hip and jack rafters, purlins where connected to common rafters and running rails and guides for sliding doors fixed with angle cleats or other connecting plates confirming to Fe-290 ( Gde E-165) complete all as specified and directed |
| 15 | M&L for two coats of synthetic enamel paint over a coat of red oxide primer on new steel surfaces over 10 cm width or girth including preparation of new surfaces. |
| 16 | M&L two coat of synthetic enamel paint over coat of Red oxide primer over Old steel surfaces nexc 10 cm width or girth complete. |
| 17 | S&F for framed work such as grills gratings, etc, with ends of bars shouldered and or riveted , or forged into spikes, framed guard bars , barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks and similar work conforming to Fe 290,E-165 , complete all as specified and directed. |
| 18 | S& F Framed work ORNAMENTAL AND INTRICATE DESIGN such as grills,gratings, etc.. with ends of barss shouldered and/or riveted or forged into spikes; framed guard bars; barred iron doors;ladders; framed balusters; walkways; railings; framework ofwater tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed. |
| 19 | Demolition of brick work or stone/ boulder masonry built in cement mortar or cement lime mortar including all quoins, arches, pillars etc complete all as specified and as directed. |
| 20 | M&L Brickwork with fly ash Modular bricks in cement mortar, straight or curved on plan exc 6m mean radius, built in built cement mortar 1:4 in complete all as specified and as directed |
| 21 | M& L for Brick work with sub-class `B' bricks, straight or curved on plan to any radius, in half brick work built in cement mortar 1:4 complete all as specified and as directed. |
| 22 | M&L Brick work with sub class B bricks straight or curved on plan exc. 6m mean radius built in cement mortar (1:6). (EXCEPT BRICS ONLY) |
| 23 | Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down wih water, etc complete all as specified and as directed |
| 24 | M&L for 15 mm thick rendering in cement mortar (1:6) on brick or concrete surfaces finished even and smooth without using extra cement complete all as specified and as directed. |
| 25 | M&L for preparation of the newly plastered surfaces of wall & applying 3 coats of white wash on Walls surfaces complete all as specified and directed. |
| 26 | Taking up or down 20mm bore steel tubing and connections including cleaning for refixing removing from site complete all as specified and as directed. |
| 27 | Taking up or down 25 mm bore steel tubing and connections including cleaning for refixing removing from site complete all as specified and as directed. |
| 28 | supply and laying 20 mm dia .of bore CPVC pipe SDR11 and Plain CPVC SDR11 fittings (ISI ) marked ,concealed or fixed to wall or laid in floors complete all as specified and as directed |
| 29 | supply and laying 25 mm dia .of bore CPVC pipe SDR11 and Plain CPVC SDR11 fittings (ISI ) marked ,concealed or fixed to wall or laid in floors complete all as specified and as directed |
| 30 | S&F 20mm dia bore Galvanised tubing medium grade with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and directed |
| 31 | S&F 25mm dia bore Galvanised tubing medium grade with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and directed |
| 32 | Dismantling of water tanks exc 250 ltr and n.exc 500ltr capacity and removing from site complete all as specified and as directed |
| 33 | Dismantling of water tanks exc 500 ltr and n.exc 1000 ltr capacity and removing from site complete all as specified and as directed |
| 34 | S&F Rotational moulded poly-ethylene multi layered antibactrial film tanks (cylinderical vertical ) 500 litres capacity, white colour hoisted and fixed in position complete all as specified and directed. |
| 35 | S&F Rotational moulded poly-ethylene multi layered antibactrial film tanks (cylinderical vertical ) 1000 litres capacity, white colour hoisted and fixed in position complete all as specified and directed. |
| 36 | S&F 20 mm Ball valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed 20mm dia of pipe . |
| 37 | S&F for in repair gun metal globe /valve with iron wheel head screwed both ends for iron pipe of 20mm bore, complete all as specified and directed. |
| 38 | Disconnecting existing water tanks, setting aside (or lowering if required) for repairs, cleaning etc and reconnecting and refixing in position capacity of tank exc 250 and n.exc 500 ltr. (cleaning, repairing etc measured separately) |
| 39 | Disconnecting existing water tanks, setting aside (or lowering if required) for repairs, cleaning etc and reconnecting and refixing in position capacity of tank exc 500 and n.exc 1000 ltr. (cleaning, repairing etc measured separately) |
| 40 | Cleaning and removing all scale and dirt etc. from tanks and from mouths of circulating pipes etc capacity of tank exc 250 ltrs but n.exc 500 Ltrs complete all as specified and as directed. |
| 41 | Cleaning and removing all scale and dirt etc. from tanks and from mouths of circulating pipes etc capacity of tank exc 500 ltrs but n.exc 1000 Ltrs complete all as specified and as directed. |
| 42 | S&F for as in repair 20 mm Ball valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed 20mm dia of pipe complete all as specified and directed. |
| 43 | S&F for as in repair 25 mm Ball valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed 25 mm dia of pipe complete all as specified and directed. |
| 44 | Dismantiling of stone slabs and tiles (Kota stone etc.) of any discription or any thickness in floors, aprons, skirting, dado etc. laid bedded and pointed in any mortar complete all as specified and directed. |
| 45 | Dismantling floor, hearth or wall tiling of any description and in any position including cement mortar bedding (but not backing) complete all as specified and directed. |
| 46 | demolition of concrete of any description and in position not otherwise specially provided for complete all as secified and directed. |
| 47 | M and L for repairing of RCC projection, chajja, facia, column etc by necessary preparation (i.e. scraping, cutting, chiseling, dusting and cleaning exposed reinforcement surface of damaged/ loose surface and applying one coat of cement slurry and filling the surface with plain cement concrete (1:1.5:3) reinforced with welded mesh and make good by15mm thick plaster with cm (1:4) and ( Chemical coating used) including scaffolding/formwork etc upto double storey height complete all as specified and directed by engineer in charge. |
| 48 | M&L for 75mm thick PCC 1:2:4 type B-1 using 20mm graded stone aggregates as in plinth protection surface finished even & smooth using extra cement providing with construction joints 10 x 20 mm filled with bitumen and sand mortar 1:3 complete all as specified and directed. |
| 49 | M&L 18-20 mm thick pre-polished Granite slab, machine cut, for floors/ shelves, cooking platforms, window cills, steps, jambs and pillar top laid over & including 20mm thick screed in CM 1:4 and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone complete all as specified & directed. |
| 50 | M&L for rounding, chamfer, splays or arris and smooth finishing at the edges of stone as in steps, cooking platform and other similar locations complete all as specified and directed. |
| 51 | M&L for PCC Type D2 (1:4:8) using 40mm graded stone agg as in foundation filling mass concrete, complete all as specified and directed. |
| 52 | M&L 25 mm thick cement concrete (1:2:4) type B-0 (12.5 mm graded stone aggregate) as in floors,finish rough to receive th\e floor finishes etc |
| 53 | Material and labour for providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with aproved colour, design & attern as in foothpath, parks, lawns, drive ways or light traffic arking etc. of required strenght, thickness & size / shape, made by table vibrating method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding / laying of interlocking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra cement complete all as specified and directed. |
| 54 | M&L for cement concrete ( 1:2:4) type B-1 (20mm graded agrregate) in lintels upto 1.5m clear span, cills, stes, seimic and other similar bands, plinth course, string course, lacing cours, arapets and railings upto 60cm in height, coping, kneelers, apex stones, bed plates, kerbs, water througs and the like including wheathering slightly rounded or chamfered angle and throating complete all as specified and directed. |
| 55 | M&L for vitrified paver color tiles 40 cmx40cmx9 to 10 mm thick, moulded set jointed and pointed in neat cement slurry with grey cement and pigment, in floors, over and including 15 mm thick screed bed or bedding layer of cement mortar (1:6) complete all as specified and directed. |
| 56 | S&F 5mm thick hollow wall panelling plain colour PVC sheet in strips & channel feathered at the edges for fixing on Solid PVC Wall Lining,Insulated PVC Wall Lining, and Solid PVC Partitions inclusive of solvent cement and fixing at site including disconnecting and refixing of electric light board complete all as specified and as directed. |
| 57 | Demolition of existing roof treatment in any description and in any position etc complete all as specified at site with APP/PCC and 10mm thick backing coat below APP and all other as specified and directed by engineer in charge . |
| 58 | M&L 40mm thick PCC type B-0, (1:2:4) using 12.5mm graded stone aggregate as in padding over roof finished and laid to required slope complete all as specified and as directed. |
| 59 | Cutting grooves in brick wall 75mm wide and 65mm deep and shaping horizontal face of groove with cement mortar 1:3 complete all as specified and as directed. |
| 60 | M&L for PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) as in roof kerbs or mud stops, rounded or chamfered on edges,finished the surface even and smooth without using extra cement complete all as specified and as directed . |
| 61 | M&L for 10mm thick plaster in CM 1:4 mixed with and including water proofing compound @ 3% by weight of cement applied over roof slab complete all as specified & directed.Note : WPC will be measured and paid separately as supply only. |
| 62 | M &L For applying water proofing treatment with the following coats :- (a) First coat of bitumen primer conforming to IS -3384 @ 0.3 Kg/sqm (b) Second Layer of APP based polymectric membrane minimum weighing 3kg /sqm and minimum 3 mm thick reinforced with polyster non woven fabric (wt. not less than 150 gms /sqm ) land on primed surface by torch application complete all as specified and as directed. |
| 63 | Apply two coats of bituminous aluminium paint over APP membrane @ 0.30 Kg/Sqm complete all as specified and directed. |
| 64 | Supply only Liquid water proofing compound complete. |
| 65 | Taking down existing tarfelt and plaster from roof and removing from site all as directed. |
| 66 | M&L for Cool Roof Tiles 9-10mm thick 300 MM X300 MM Size (Make: Orient Bell or Equivalent ceramic tiles white confirming to sun reflective Index (SRI) value minimum of 90 on 15mm thick 1:3 screed bed complete all as specified and directed. |