| 1 | Dismantling water tanks and removing to store of capacity exc 250 & n.exc 500 ltrs. |
| 2 | Dismantling water tanks and removing to store of capacity exc 500 & n.exc 1000ltrs. |
| 3 | S&F Rotational moulded PVC water tanks of 500 Ltrs capacity, cylindrical vertical with closed top hoisted and fixed in position |
| 4 | S & F 1000 ltrs rotational moulded polyethelene water storage tanks (cyclindrical vertical with closed top) incl connecting up pipes securing access covers etc as specified and as directed. |
| 5 | S&F Ball brass valve, high pressure, with polythene float and fly nut complete screwed for iron pipe or brass ferrule and fixed complete of 20 mm bore dia. |
| 6 | Taking down existing tarfelt including tiles and Demolition of lime concrete & screed bed complete from roof surfaces including parapets and lowering without disturbing the existing RCC roof slab and removing the same outside premises incl roughening of old concrete surface of roof by wire brushing and cleaning the surface to remove all loose dust etc complete all as specified and as directed. |
| 7 | M&L for 10mm thick plaster in cement mortar (1:4) in order to maintain proper slope over existing roof surfaces for laying APP based polymeric membrane, and water proofing compound @ 200ml per bag complete all as specified and as directed. (NOTE : Polymeric membrane & Water proofing compound shall be measured and paid separately under relevant item of this Schedule 'A', ). |
| 8 | M&L Brushing neat cement slurry with 3.0kgof cement per sq. metre of old concrete surface on roof surfaces. |
| 9 | M&L for water proofing treatrment to RCC roof slab, including parapet comprising with the following courses of treatment/specification from bottom to top :- (a) Applying bitumenous primer @ 0.4 ltrs per Sqm over plastered surfaces of roof incl parapet surface. (b) Over the priming coat laying one layer APP based polymembric membrane of approved manufacturer 3mm thick weight not less than 3 Kgs per Sqm reinforced with non woven polyester febric weight not less than 150 gms per Sqm. Polymeric membrane shall be taken to a height of 60cm (min) and then inserted inside the groove of parapet wall and shall be finished by a membrane flashing. (Note :- (i) Laying APP bassed polymenic membrane shall be done torch on methed or as per manufacturer's instructions. (ii) A minimum overlap of 100mm and 75mm should be made at the end and sides of the polymeric membrane respectively and sealed all overlaps and joints as per manufacturer's instruction. (iii) APP bassed polymeric membrane shall be \\"Dr Fixit\\" manufacturered by M/S Pidilite Industries or \\"MOPLY FP 3MM\\" manufactured by M/S Texsa India Limited and 'Hyperplus\\" by IWL India Limited(iv) Applying two coats of Aluminium paint over APP membrane.) |
| 10 | Dismantling corrugated steel sheeting, any gauge, thickness incl ridges complete all as specified and as directed. |
| 11 | Dismantlings Asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings |
| 12 | Dismentling wrought iron or mild steel work of any description not otherwise provided for roof trusses and purlins complete all as specified and as directed. |
| 13 | S&F of rolled mild steel sections as in roof trusses (framed), trussed, purlins, crane gantry, rails, fasteing, heavy bracket framing (Beam, tee, angle, chanel or flat section), including distance pieces, cleats etc. confirmig to Fe - 410- W including cutting, welding & necessary fittings such as nut bolt, plate complete all as specified and directed. |
| 14 | S&F 0.5mm thick corrugated \\"Galvalume\\" pre painted aluminum zinc coated GI based corrigated steel sheet colour having tensile strength of 550MPA as in roof covering/cladding to wall, fixed with self tapin screw all as specified and as directed. |
| 15 | S&F 0.5mm thick plain steel sheet pre painted Galvalume aluminum zinc coated GI based corrigated steel sheet colour having tensile strength of 550MPA as in roof covering/cladding to wall, fixed with self tapin screw all as specified and as directed. |
| 16 | S&F 0.63mm thick galvanised, corrugated mild steel sheeting with two corrugation side lap, fixed with 'L' or 'J' type or cranked hook bolts and washers in roofs, wall etc all as specified. |
| 17 | Dismantling floor, hearth or wall tilling including cement mortar being (but not backing), and rubbish off the premises complete all as specified and directed. |
| 18 | Demolition of cement concerte (unreinforced) of any description and in any position not otherwise specifically provided for complete all as directed |
| 19 | M&L for 25mm thick PCC (1:2:4) type B-0 with using 12.50 mm graded stone aggregates as in sub base of flooring, finished even and rough to receive the top layers all complete as specified and as directed. |
| 20 | M&L for 10mm thick rendering in CM (1:4) as in vertical surfaces of skirting dados repairs to steps complete all as specified and directed. |
| 21 | M&L for 15mm thick screed bed or bedding layer in CM (1:6) as in floor complete all as specified. |
| 22 | M&L for Vitrified light shade tiles 10 mm thick (square/rectangular) area of each tile not less than 0.36 Sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match all as specified and as directed. |
| 23 | Description all as per Ser item No 22 above but as in skirting |
| 24 | M&L for 18 to 20mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like incl 15mm thick in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite all as specified and directed. |
| 25 | M & L Machine cut kota stone slab in flooring 20 to 25 mm thick over and including 20mm thick cement screed base in CM (1:6) laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab incl rubbing and polishing complete all as specified and as directed. |
| 26 | M&L for kota stone slab 18-20mm thick in riser or steps, skirting, dado and pillar laid over and including10 mm thick screed bed cement screed (1:4) and jointed with grey cement slurry mixed with pigment to match the shade fo the slab including rubbing and polishing complete all as specified and as directed. |
| 27 | Taking down cement plaster on wall of any desription incl racking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed. |
| 28 | M&L for Rendering 15 mm thick in CM 1:6 on fair faces of brick work or concrete surfaces, finished even & smooth without using extra cement. |
| 29 | M&L for 15mm thick plaster of cement mortar (1:4) rendering on fair faces of brick work in two layers (10mm and 5mm thick) mixed with water proofing compound in top layer @200ml per bag 50kg of cement or as per manufacturer's instructions finishing the surface even and smooth without using extra cement complete all as specified and as directed.Note : water proofing compund shall be measured and paid separtely. |
| 30 | Supply only Liquid water proofing compound conforming to IS: 2645 - 1975 specification complete all as specified and as directed |
| 31 | M&L for two coats of Distemper on walls over New plastered surfaces of wall incl preparation of surfaces complete all as specified and as directed. |
| 32 | Preparation of new plaster or un-plastered surfaces of walls and applying two coats of Preparing surfaces plastered or unplastered old surface but applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10sqm over new surfaces on walls complete all as specified and as directed. |
| 33 | Supply & Fixing in repair 18-19mmm Prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work complete all as specified and as directed. |
| 34 | M&L for 18/19mm thick extra over rates of block board or veneered particle board for external teak wood lipping, 6mm thick fixed with nails Supply & Fixing in repair |
| 35 | Dismantling of wall and ceiling boards any thickness including cover cover fillets complete all as specified and directed. |
| 36 | Dismantling timber scantlings as in fillets, rails, posts, rafters, purlins etc under 40 Sqcm in section in unframed work. |
| 37 | S&F Anodised aluminium snap grid frame work for false ceiling size of grid 605 x 605mm with Hangers 6 mm dia. G.I. (upto 1200mm length) with 4mm thick Non asbestos fibre cement building boards fixed or laid/ inserted to timber/GI/Aluminium framework with screws complete all as specified and directed. |
| 38 | Demolition of brick work or stone/boulder masonry built in cement mortar incl all quoins, arches, pillars etc but excluding ashlars facings dressed stone work and Precast concrete articles, complete all as specified and directed. |
| 39 | M&L brick work with sub class 'B' bricks, straight or curved on plan exc 6 m mean radius, built in CM 1:6 |
| 40 | Description all as per Ser item No 39 above but except brick. |
| 41 | Demolition of RCC any thickness and any size as in columns, roof slab, chajja, facia and beam etc complete all as specified and as directed. |
| 42 | M&L for RCC type B1 (1:2:4) in beams,cantilevers, bressumers, lintels, chajjas |
| 43 | M&L mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, binding spirally for hooping for columns, hooking ends and binding with and including MS wire (annealed) n. less than 0.9mm dia. |
| 44 | M&L formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressum-mers, lintels, cantilevers, shelves including supports, overhangs etc also splays between floors and beams for flat rough finished surface etc. |
| 45 | Preparation of New /untreated steel and iron surfaces of any description, over 10 cm in width or girth not otherwise described (including roof surfaces) and applying Two coat of synthetic enamel paint over one coat of redoxide all as specified and directed. |
| 46 | Disconnecting existing tanks, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position of exc 250 & n exc 500 ltr capacity.including Cleaning and removing all scale and dirt, etc, from tanks and from mouths of circulating pipes, etc. |
| 47 | Disconnecting existing tanks, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position. of exc 500 & n exc 1000 ltr capacity including Cleaning and removing all scale and dirt, etc, from tanks and from mouths of circulating pipes, etc. |
| 48 | M&L 15mm thick rendering on fair faces of bk /concrete surfaces in cm (1:4), finished even and smooth (Without using extra cement ) including scafolding up to G+3 story bldg, etc complete.complete |
| 49 | M&L three coat of white wash on Newly Plaster prepared surfaces on wall , etc complete. |
| 50 | M&L three coat of Cement base paint on Newly Plaster prepared surfaces on wall including scafolding up to G+3 story bldg, etc complete. |
| 51 | M & L for preparing old plastered surfaces of wall and applying two coat of white wash on walls |
| 52 | M & L for preparing old plastered surfaces of ceilings and applying one coat of white wash on ceilings complete all as directed |
| 53 | M & L for preparing old plastered surfaces of wall and applying two coat of Cement base paint on walls including scafolding up to G+3 story bldg, etc complete. |
| 54 | M&L Complete removal of existing treatment,Preparing surfaces plastered or unplastered old surface but applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10sqm over new surfaces. |
| 55 | M&L wall care putty 2mm thick including necessay preparation or already prepared surface complete all as specified and directed. |
| 56 | M&L for preparation of old wooden surface of any description over 10 cm width or girth and applying one coat of synthetic enamel paint white or tinted complete all as directed. |
| 57 | M&L for preparation of old wooden surface of any description over 10 cm width or girth and applying two coat of synthetic enamel paint white or tinted complete all as directed. |
| 58 | M&L for preparation of old painted steel surface of any description , over 10 cm width or girth not otherwise described and applying one coat of synthitic enamel paint white or tinted all as directed. |
| 59 | M&L for preparation of old painted steel surface of any description , over 10 cm width or girth not otherwise described and applying two coat of synthitic enamel paint white or tinted all as directed. |
| 60 | Taking out defective submersible pump set installed at 200-400 feet depth including disconnecting electric connections, removing submersible cable, GI column pipe, safety rope, and all accessories using tripod/winch/chain pulley/Hydra arrangement, servicing and repair of submersible pump capacity upto 15 HP including dismantling of pump and motor, cleaning of impellers, shaft alignment, greasing, replacement of gasket set, gland packing, minor hardware, and reassembly and transporting the defective borewell to workshop. after repair lowering and re-installation of repaired submersible pump set back to 200–400 feet depth including lowering of GI pipe column/PVC pipe, submersible cable, clamp arrangement and reconnection of starter suitable for the rating of existing submersible pump, including wiring connections. After installation, the system shall be tested including megger test of cable and motor, running and load current check, leak testing, discharge verification and handing over the system in fully satisfactory operational condition complete as directed by Engineer-in-Charge.Note:(a) Unit rate quoted shall deemed to include only labour for taking up & lowering the submersible pump from bore well along with delivery pipe complete(b) Repairs/rewinding of submersible pump shall be measured & paid for separately under relevant items.(c) Replacement of colummn pipe will be measured and paid for separately as supply only, under relevants items. (d) Expendable stores like cotton waste / cleaning materials, lubricants, gland packing, metal filling, machining and transportation from site to work shop and back are deemed to be included in rate quoted |
| 61 | M&L for rewinding the Submersible pump Motor with PVC insulated, super enamelled copper conductor with ‘F’ class heavy grade insulation weight and turns to achieve its full efficiency including tying the winding and connecting the coils and brining the connections as that of existing one including applying insulating varnish, heating and backing the windings thoroughly including taking down old existing copper winding complete all as specified and directed for Submersible pump motor of following capacity :- |
| 62 | Description all as per Ser item No 61 above Submersible Motor up to and including 5 HP. |
| 63 | Description all as per Ser item No 61 aboveSubmersible Motor above 5 HP up to 10 HP. |
| 64 | Dismantling and taking out the centrifugal pumping set with motor from the existing foundation for carring necessary repair/ servicing by replacing the unservicable parts including overhauling the pump set, renewal of gasket to pump, suction and delivery lines, gland packing, greasing nuts, bolts and washers, re-connecting up of the electric / water connections, including fixing of new coupling (CI/rubber) as per existing all as required at site of work of capacity upto 40 HP, including re-fixing at same location including aligning and commissioning complete all as specified and directed.Notes:- (i) Expendable stores like cotton waste / cleaning materials, lubricants, gland packing etc., and transportation from site to work shop and back are deemed to be included in unit rate quoted.(ii) Labour element is deemed to be included in unit rate quoted. |
| 65 | M&L Dismantling and strip opening the motor completely including disconnecting the cable connections and coupling of the motor removing the starter and rotor units, bearings complete servicing the motor assembly including cleaning the carbon deposits with carbon tetra chloride, greasing the bearings etc., heat varnishing the motor windings by applying varnish and keeping the windings into the hot air oven till the moisture evaporates complete at authorized workshop including transportation and refit the same after repairs and re-connecting up of the electric connections including testing and commissioning complete all as specified and directed for the following capacities:- |
| 66 | Description all as per Ser item No 63 above for Induction Motor 40 HP capacity. |
| 67 | M&L cutting and taking out the unserviceable / burnt out copper winding from the electric motor, preparation of the surface and rewinding the same with super enamelled copper conductor with ‘F’ class heavy grade insulation, weight and turns to achieve its full efficiency including tying the winding and connecting the coils and brining the connections as that of existing one including applying insulating varnish, heating and backing the windings thoroughly with necessary insulating materials complete all as specified for the capacities upto 100 HP motor |
| 68 | Supply and fix Ball bearing in replacement for electric motor of capacity 40 HP, 3 Phase as per existing make and model complete all as specified and directed. Make : Hindustan Brown Breware and equivalent |
| 69 | Supply and fix Ball bearing in replacement for electric motor of capacity 7.5 HP, 3 Phase as per existing make and model complete all as specified and directed. Make : Hindustan Brown Breware and equivalent |
| 70 | Supply and fixing in replacement of power contactor type ML-1 complete all as specified and directed. |
| 71 | Supply and Fix Copper lugs of different capacity and size as directed and specified by engr-in- charge. |
| 72 | M&L Stainless steel nut, bolts and washers of different sizes as directed and specified by engr-in- charge. |
| 73 | Supply only LT tape fire resistant type complying IS 7809, 1.8 cm width & 25 mtr length all as directed and specified by engr-in- charge. |
| 74 | S&F in replacement 3 phase 415 Volts, submersible pump controller MU-G6 (5 HP - 7.5 HP DOL) or 3 seat enclosure with over load, short circuit, under current, unbalance, phase reversal, phase loss,locked rotar, eath fault, stall ,CB failure with fault record with date and time, having feature of fail safe operation, and over load characterstic rating 14 Amps, relay range 9 to 14 Amps, including connecting up of incoming and outgoing connections and testing commissioning, including removing the existing unserviceable one complete all as specified and directed. Please Enable Macros to View BoQ information |
| 75 | S&F in replacement 3 phase 415 Volts, submersible pump controller MU-G6 (5 HP - 7.5 HP DOL) or 3 seat enclosure with over load, short circuit, under current, unbalance, phase reversal, phase loss,locked rotar, eath fault, stall ,CB failure with fault record with date and time, having feature of fail safe operation, and over load characterstic rating 14 Amps, relay range 9 to 14 Amps, including connecting up of incoming and outgoing connections and testing commissioning, including removing the existing unserviceable one complete all as specified and directed. Please Enable Macros to View BoQ information |