| 1 | Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm,watering and removing surplus soil to a distance n. exc 50 m and making good surface in soft/loose soil complete all as specified and as directed. |
| 2 | M&L for PCC (1:2:4) type B-2, using 40mm graded stone aggregate as in foundation filling & mass concrete complete all as specified and as directed. |
| 3 | S & F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 4 | M & L for Roof Trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat section) including distance pieces, cleats etc complete all as specified and directed. |
| 5 | M & L for Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240 including rolled mild steel as in joint channel, angle or tee sections fixed independently withouy connection plates etc., (cut to ordinary length ie within 20mm of tile length indicated of gde Fe 410-S complete all as specified and directed. |
| 6 | M & L for preparation steel surfaces over 10cm width or grith and applying two coat synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. |
| 7 | M & L for Mild steel screw bolts (machine made ) with hexagonal or square heads at one end and screwed the other or screwed both ends ,each screwed end to be fiitted with washer and one hexagonal or square nut length of bolt exc 5 cm but n exc 10cm long complete all as specified and directed. |
| 8 | Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out and getting out in soft / loose soil complete all as specified & directed. |
| 9 | Excavation in trenches n exc 1.50 mtr wide and n exc 1.50 mtr depth for foundation etc and getting out in soft / loose soil complete all as specified & directed. |
| 10 | Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed. |
| 11 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm.in soft and loose soil complete all as specified and directed. |
| 12 | M&L for PCC (1:4:8) type-D2, using 40 mm graded stone aggregate as in sub base, filling and mass-concrete complete all as specified and directed. |
| 13 | M&L for hard core of gauge n exc 63mm deposited spread and levelled in layers n exc 15cm thick watered and rammed to a true surfaces of broken stone or boulder complete all as specified and directed. |
| 14 | M&L for sand filling under floor or in foundation including spreading levelling, watering and well ramming in layers not exc 25 cm etc complete all as specified and directed. |
| 15 | M&L for 75mm thick PCC 1:4:8 type D-2 using 40mm graded stone aggregate as in sub base of floor complete all as specified and directed. |
| 16 | M&L for 100mm thick cement concrete 1:4:8 type D-2 using 40mm graded stone aggregate as in sub base complete all as specified and directed. |
| 17 | Material & labour PCC (1:3:6) Type C1 (using 20 mm graded stone aggregate), 75 mm thick as in plinth protection and finishing surfaces even & smooth without using extra cement including mist filling in the joint complete all as specified and directed. |
| 18 | Formwork to sides of concrete foundations, footings, bases of columns, plinth beams, fair finished surface complete all as specified and directed. |
| 19 | M&L for M25 (20mm graded aggregate) Reinforced cement concrete (design mix) for foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc. all as specified and directed. |
| 20 | Formwork to sides of pillars, posts, struts, piers, columns and stanchions etc. fair finished surfacecomplete all as specified and directed. |
| 21 | M&L for M25 (20mm graded aggregate) Reinforced cement concrete (design mix) for Column, pillars, piers, posts and struts for supporting of beam etc complete all as specified and directed. |
| 22 | Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. complete all as specified and directed. |
| 23 | M&L for M25 (20mm graded aggregate) Reinforced cement concrete (design mix) for Beams, cantilevers, bressummers, lintels over 1.5m span all as specified and directed. |
| 24 | Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) etc. complete all as specified and directed. |
| 25 | Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide |
| 26 | M&L for M25 (20mm graded aggregate) Reinforced cement concrete (design mix) slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed. |
| 27 | M&L for M25 (20mm graded aggregate) Reinforced cement concrete (design mix) slabs supported on walls, chajjas, and in shelves and the like complete all as specified and directed. |
| 28 | S&F for TMT bars 10mm dia and over, cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire(annealed) not less than 0.9mm dia or securing with clips. |
| 29 | S&F for TMT bars 6 to 8mm dia, cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire(annealed) not less than 0.9mm dia or securing with clips. |
| 30 | M & L for brick work with fly ash bricks straight or curved on plan exc 6 mtr mean radius built in CM 1:6(Using old size brick) complete all as directed. |
| 31 | M & L for brick work with fly ash brick, straight or curved on plan to any radius built in half brick thick wall built in cm 1:4 (Using old size brick) complete all as specified and directed. |
| 32 | M&L for cement plastering 15mm thick in two layers (10mm and 5mm respectively) in cemet mortar 1:4 including mixing of liquid water proofing compound as per manufacturer's instructions on brick work or concrete surfaces or in chajjas/parapet walls etc finished even and smooth without using extra cement and fixing of chicken wire gauge where directed complete all as specified and as directed by Engineer-in-Charge. Note : WPC will be measured and paid separately. |
| 33 | Supply only integral liquid water proofing compound complete all as specified & as directed. |
| 34 | Supply only chicken wire mesh 22 gauge of size not less than 20X20mm all as specified & as directed. |
| 35 | M&L for cement plastering 10mm thick in cemet mortar 1:6 on brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and as directed. |
| 36 | M&L for cement plastering 5mm thick in cemet mortar 1:3 as on ceilings or concrete surfaces finished even and smooth without using extra cement complete all as specified and as directed. |
| 37 | Preparation of surfaces and applying 02 coats of interior emulsion paint (light shade) @ 10 sq.m/litre/2 coats by using roller/brush to wall surfaces over & including a coat of interior wall primer @ 10 sq.m/litre/1 coat as recommended for under coat by manufacturer of interior emulsion and primer including Applying acrylic thick wall care putty on internal surfaces of walls/ceilings (thickness vary from 1.5 to 2.5 mm as required for desired smoothness and levelling of surfaces in two or more layers) by using ready made wall care putty including sand papering after filling the putty to make surface smooth and ready for receiving exterior painting complete all as specified and directed. |
| 38 | Preparation of surfaces and applying 02 coats of exterior emulsion paint (light shade) with highlighter of any approved shade, @ 5 sq.m/litre/2 coats by using roller to external walls/RCC surfaces/soffits of chajjas/roof projections/cantilevers/balcony etc surfaces over & including a coat of exterior wall primer @ 11 sq.m/litre/1 coat as recommended for under coat by manufacturer of exterior emulsion, including Applying acrylic thick wall care putty on internal surfaces of walls/ceilings (thickness vary from 1.5 to 2.5 mm as required for desired smoothness and levelling of surfaces in two or more layers) by using ready made wall care putty including sand papering after filling the putty to make surface smooth and ready for receiving exterior painting complete all as specified and directed. |
| 39 | M&L for preparing new plastered surfaces of ceilings and applying three coats of white wash by making the lime slaked at site and shall be mixed and stirred with about five liters of water for 1 kg of unslaked lime to make a thin cream. This shall be allowed to stand for a period of 24 hours and shall then be screened through clean coarse cloth. 1 kg of gum dissolved in hot water shall be added to every one cubic meter of lime cream. About 1.3 Kg of sodium chloride dissolved in hot water shall also be added for every 10 kg of lime for making the coating hard and rub-resistant. Small quantity of ultramarine blue (upto 3 gm per kg of lime) shall also be added to the last two coats of white wash solution and the whole solution shall be stirred thoroughly before use complete all as specified. |
| 40 | Supply & Fixing Factory made single extruded WPC ( Wood Polymer Composite ) Solid Door Frame / Chowkhat of Size 45mm x 70 mm comprising of virgin polymer of K value 58-60 (suspension grade ), Calcium Carbonate and nautral fibers ( Wood Powder / Rice husk / Wheat husk ) and non toxic additives (maximum toxcity index of 12 for 100 gms ) fabricated with miter joints after applying PVC Solvant cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg /cum and screw withdrawl strength of 2200 N (face ) & 1100 N (Edge) minimum Compressive strength of 58 N /sqmm modulus of elasticity 900 N/Sqmm and resisitence to spread of flame of class A category with property of being termite / borer proof , water moisture proof and fire retaident and fixed in position with and including MS hold Fast lugs / SS Dash Fastner of required dia and length with and including Supply and Fixing (03 Nos Per Frame ) 100 mm long SS Butt Hinges with and Including taking down of existing door frame and making good with plastering/rendering etc. around the finished opening of the distrubed surface with Cement Mortar 1:4 complete all as specified and as directed. |
| 41 | Supply & Fixing Factory made single extruded WPC ( Wood Polymer Composite ) Solid Plain flush door shutter of 30 mm size comprising of virgin polymer of K value 58-60 (suspension grade ), Calcium Carbonate and nautral fibers ( Wood Powder / Rice husk / Wheat husk ) and non toxic additives (maximum toxcity index of 12 for 100 gms ) having minimum density of 650 kg /cum and screw withdrawl strength of 1800 N (face ) & 900 N (Edge) minimum Compressive strength of 50 N /sqmm modulus of elasticity 850N/Sqmm and resisitence to spread of flame of class A category with property of being termite / borer proof , water moisture proof and fire retardant and with and including Supply & Fixing of 02 Nos (per Leaf) SS 150mm long Tower Bolt, Supply & Fixing of 02 Nos (per door) SS 300mm long Sliding Bolt with and including S&F of 02 Nos (per Leaf) SS 150mm long handle with and including taking down of existing shutter complete all specified and directed. |
| 42 | Providing and fixing factory made uPVC white colour casement/sliding window/door, made of extruded profiles. Profi l e s of frames (60x58) and sash will be mitered cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc.. making arrangement for fixing of hardware, EPDM gasket, 1.2 + 0.2.mm thick galvanized steel profile to be inserted in required profile, frame will be fixed to the wall with 8mm x 100mm long fastener s, complete all specified and directed. (Glazing, hardware hinges and fitting, EPDM rubber gasket etc. to be paid separately.) Note:-Each member of window to be measured separately wrth clear length. |
| 43 | Providing and fixing factory made uPVC white colour casement (Openable) window/ventilator made of extruded profiles with wall thickness of 2.3mm ( + – 0.2mm). Window profile with hollow section with multi chamber, frame (60mm x 58mm), sash (60mm x 73mm),T profile (One vertical length in between two shutters)(60mm x 74mm), Glazing bead (35mm x 20mm) will be mitered cut and fusion welded at all corners, includingdrilling of holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware.EPDM gasket 1.2 +– 0.2mm thick, galvanized steel Frame (28mm x 21.5mm), sash (31mm x 27.5mm). T profile (27mm x 17mm) to be inserted in required profile, frame will be fixed to the wall with 8 mm x 100mm long fasteners. Hardware: [casement handle made of zinc alloyed (white powder coated), But Hinges of'zinc alloyed (white powder coated), transmission gear made of mild steel with multi point locking system] and 5mm thick glazing with selected quality glass complete all specified and directed.(Note: The unit rate quoted by contractor excludes cost of glass and includes all other connected accessories. Net opening will be measured forpayment purpose.) |
| 44 | S&F for sheet glass 5.00 mm thick tinted quality and glazing complete all specified and directed. |
| 45 | S & F stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.4mm and fixed with tinned tacks to stainless steel wire staple complete all as specified and directed. |
| 46 | M&L for anti-skid premium quality coloured tiles 400 X 400 mm and 7-8 mm thick, as in floors etc. in any pattern of light & dark tiles as approved, set and jointed in neat cement slurry and pointed in white or coloured cement to match, in floors etc. over & including 20 mm thick screed in cement mortar (1:4) over and pointed in white cement with pigment to match the colour of tiles complete all as specified. |
| 47 | Providing and Laying Premium (1st) quality straight edge, stain free, gloss finish, square marbonite double charged vitrified tiles in 600x600x 9 to 10 mm thick in approved shade, set & jointed in neat and pointed in white or coloured cement to match, as in skirting not 150mm high etc. in any pattern of light or dark tiles as approved, over & including 10 mm thick screed in cement mortar (1:4) complete all as specified and directed. |
| 48 | Providing and Laying Premium (1st) quality digitally printed straight edge, punched, glazed ceramic rectangle tile in approved shade and finish with flexural strength greater than 16 N/mm2, scratch hardness on Moh’s Scale minimum 3 and crazing resistance of 2 cycles in coloured tiles 450mmx300mm/600 X 300 mm and 8-9 mm thick, in any pattern of light & dark/highlighters tiles etc as approved, on vertical surfaces such as in skirting/dado etc, set and jointed in cement slurry over & including 10 mm thick rendering in cement mortar (1:4) and pointed in white cement with pigment to match the colour of tiles complete all as specified and directed.Note : Dado should be flushed with the wall plastering. |
| 49 | Supply and Fixing CPVC pipes SDR 11 including with fittings (such as elbow, Tee, socket etc) and fixed to walls & ceiling or laid in floors, outer dia of pipe 15mm and making good as per existing surfaces complete all as specified and directed. |
| 50 | Supply and Fixing CPVC pipes SDR 11 including with fittings (such as elbow, Tee, socket etc) and fixed to walls & ceiling or laid in floors, outer dia of pipe 20 mm and making good as per existing surfaces complete all as specified and directed. |
| 51 | Material and labour for Cutting grooves in brick wall, 75mm wide and 65mm deep and shaping horizontal face of groove with cement mortar 1:3 etc complete all as specified and directed. |
| 52 | S&F in repairs single liver basin mixer with popup waste system & 450mm long braided hoses, fency type, cast copper alloy, with capstan heads, chromium plated, screwed down, high pressure, with long screwed shanks and fly nuts, screwed for 15mm bore of iron pipe and all as specified. |
| 53 | S&F Bib taps, CP, fency type long body with wall flange screwed for 15mm bore of iron pipe or for brass ferrule and fixed in position complete all as specified all as specified. |
| 54 | S&F Stop valves, fancy type, CP with long shank and cup ( concealed typee ), exposed part kit with wall flange and regular body of concealed stop cock suitable for 15mm line with protection cap fixed in position complete all as specified all as specified. |
| 55 | S&F Angular Stop Cock with wall flange, fency type chromium plated cast copper alloy screwed down, high pressure, screwed one ends for 15mm bore of iron pipe or for union and fixed in position complete all as specified all as specified. |
| 56 | S&F vitreous china premium/1st quality wash basin,Counter Type white/ivory/off white, size 580x430 mm including S&F all accessories as recommended by manufacturer and incl. CP bottle trap/waste fitting (where as required) 32 mm with inlet and outlet screwed for pipe or connections incl all necessary accessories for fixing, packing, union and incl 32mm brass CP waste coupling and complete fixed in position in all respect as per manufacturer's instructions and taking down existing of any description/size complete all as specified all as specified. |
| 57 | S&F vitreous china premium/1st quality wash down water closet pan\\"EWC Wall Hung with P Trap (pedestal pattern/EWC) S/P trap white colour of size 520X360X390mm including connection to drain (or out going pipe) and to flushing pipe, antisyphonagee pipe,etc.,with flush pipe and incl. S&F plastic seat cover as recommended by manufacturer closed pattern with flat bottom etc; and incl all necessary accessories like rag bolts/gel gasket etc as recommended by manufacturer for fixing, packing complete all as specified all as specified. |
| 58 | S&F concealed flushing cistern of PVC 10 ltr. cap. with dual flushing system, valveless syphonic action type, with inlet/outlet, ball valve, float and including brackets and connection to pipe etc. and incl S&F of all necessary accessories/installation kit and 'S' type drain pipe connetion set for wall hung WC etc as recommended by manufacturer for fixing, packing and including S&F of actuator knob/flush plates and and taking down existing of any description/size complete all as specified all as specified. |
| 59 | S & F in repairs PVC connections 15mm size with brass nuts of length 450mm complete all as specified all as specified. |
| 60 | S&F in repairs PVC waste pipe with socket suitable for connection to Waste fittings of 32/40mm dia, and of length minimum 75 cm complete all as specified all as specified. |
| 61 | S&F doubled layered rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top / cover) 1000 Ltrs capacity hoisted and fixed in position all as specified including ball brass valves, high pressure, with polythene float and fly nut complete screwed for 20mm bore iron pipe and including GI nipple/union of 20mm bore to connect GI tubing to PVC tank complete all as specified and directed. |
| 62 | S&F 20 mm Gun metal gate valve with iron wheel head screwed both ends for iron pipe and fixed to 20 mm bore pipe complete all as specified and directed. |
| 63 | S&F cockroach trap gratings AISI-304 of size 150X150mm square in shape with 5mm border complete all as specified and directed. |
| 64 | S&F 6mm thick looking mirror fixed to wall with stainless steel plugs/connecter/spacers/screws etc. chrome finish with wooden beading french polished, etc.complete fixed in position complete all as specified and directed. |
| 65 | S&F sheet glass shelf assembly of 300X300mm for corners consisting of 5.5 to 6mm thick glass shelf and with bevelled edges/hatching of edges fixed with stainless steel 'D' bracket fixed and railing complete all as specified and directed. |
| 66 | Supply and fixing chromium plated brass towel rail, 20mm dia, D type, 60cm long fixed to wall complete all as specified and directed. |
| 67 | Material and Labour Vitreous China Urinal, Half stall type, white, including connections to flushing pipe and outgoing pipes , including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating, PVC bottle trap etc,, including CP urinal spreader and CP connection and 32mm bore waste pipe complete all as specified and directed. |
| 68 | Material and Labour Green Marble work 18 to 20mm thick (table rubbed and polished) in steps, jambs, pillars, windowcills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with marble shade complete all as specified and directed. |
| 69 | S&F PVC(HDPE) SWR , 110 mm bore, single socketed in any length with rubber ring joints using solvent as per maunfacture instruction, fixed to walls complete all as specified including fixing of pipe to wall with flat iron clamps of size 25 x 3mm, bolts, washers, nuts, nails etc, after taking down existing damaged rain water pipe complete all as specified and directed. |
| 70 | S&F 75 mm bore of pipe PVC(HDPE) (SWR) Type 'B' pipes single socket in any length with rubber ring joint, PVC Clamps whereas required, fixed to walls / floor / trenches with fittings (such as bend, socket, 'Y' junction etc) including and any description with fittings,complete all as specified and directed.Note: Excavation and earth work shall be measured and paid separately. |
| 71 | Material & Labour for 75 mm dia PVC (SWR) floor trap, plain with grating including jointing with solvent complete all as specified and directed by Engineer-in-Charge. |
| 72 | M&L filling 100mm Hard core, broken stone/boulders to gauge n exc 63mm complete all as spefcified |
| 73 | M&L 75 mm thick cement concrete in foundation type D-2 1:4:8 (40 mm graded aggregate ) and mass concrete complete all as spefcified |
| 74 | S & F machine pressed precast concrete interlocking paver block any shape and size confirming to SI 15658-2006 of 60 mm thickness, M-35 grade with grey cement and no pigment complete all as spefcified |
| 75 | M&L for 25mm thick sand filling under interlocking tiles including watering and consolidating complete all as spefcified |
| 76 | M&L cement concrete type B1 ,1:2:4 mix (20 mm stone aggregate) as in bedding ,benching,of manhole ,coping etc complete all as specified and directed. |
| 77 | Dismantling of Stone slabs and tiles laid, bedded and pointed in any type of mortar of any description or thickness in floors, aprons etc complete all as specified and directed. |
| 78 | Glazed Vitrified heavy duty outdoor tiles 10 mm thick (square/ rectangular) polished, area of each tile not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match to match the shade of tiles over and including 15 mm thick screed plaster with adhesive complete all as specified and directed. |
| 79 | M&L Granite work 20 mm thick (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms etc like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite including 15 mm thick Screed bed or bedding layer in CM 1:4 complete all as specified and directed. |
| 80 | M & L in repair PCC 1:2:4 for PCC type B-0 using 12.50 mm graded stone aggregate as in coping steps bed blocks etc of any thickness , complete all as specified and directed. |
| 81 | M&L rendering 10mm thick plaster in cement mortar 1:4 on fair faces of brick work or concrete surface complete all as specified and directed. |
| 82 | M&L brick work with sub class 'B' old size bricks straight or curved on plan exc 6 m mean radius built in CM 1:6 incl demolition of old brickwork complete all as specified and directed. |
| 83 | M&L for 10 user 2000 ltrs capacity PVC moulded anaerobic Septic tank for an anaerobic design in which bacteria treats waste under most favourable conditions, process effectively prevents rapid accumulation of sludge and suspended solids from passing through the system untreated with innovative engineering design of the inlet-outlet short circuit of waste water which is prevented to ensure long and enough retention time for effective treatment, thus the effluent does not contain any solid or scum that would clog up the pipe line. the septic tank is burried underground, solid and liquid waste flow in to it. Heavy solid waste settle in to the bottom of the septic tank (known as sludge).The liquid wastes are also held in the septic tank while bacteria break down solids into liquids in an anaerobic environment, process ins known as primary treatment, some bacteria and viruses are absorbed on to solid particles and held in the sludge or scum layers, allowing for limited removal of disease causing organisms at the stage. all that has to be done for fitting the tank is to fill the tank with water, connect the drain line to the inlet and outlet to the soak pit, cover the manholes with the lids provided and tank is ready to use incl PCC 1:4:8 below foundation and vent shaft connection, including excavation, returning and filling, removal of excess soil, connection to sewage line including site clearance etc complete all as specified and directed by Engineer-in charge |
| 84 | M & L for PVC manhole of PE material single piece manhole of size 800mm dia 3 to 5 no of inlet/outlet options and with riser height 1250 to 1500mm with inlet option of dia 160/200/250mm and outlet option 160/200//250mm with 600mm dia manhole cover fixed over 100mm thick pcc base in 1:4:8 complete all as specified and as directed. |
| 85 | Excavation over areas not exceeding 1.5 mtr deep in soft/loose soil and getting out of soil complete all as specified and directed. |
| 86 | Exacavation of areas exceeding 1.5 mtr and not exceeding 3.0 mtr deep in soft/loose soil and getting out of soil complete all as specified and directed. |
| 87 | Exacavation of areas exceeding 3.0 mtr and not exceeding 4.5 mtr deep in soft/loose soil and getting out of soil complete all as specified and directed. |
| 88 | M & L for PCC 1:3:6 type B-2 using 40mm graded crushed stone aggregates as in foundation filling, sub-base and mass concrete complete all as specified and directed. |
| 89 | M & L for broken bricks of gauge not exceeding 63 mm, deposited, spread and leveled in layers n.exc 15 cm thick, watered and rammed complete all as specified and directed. |
| 90 | M & L for brick work with sub class ‘B’ bricks old size, straight or curved on plan exc 6 metre mean radius in CM 1: 4 complete all as specified and directed. |
| 91 | M & L for brick work with sub class ‘B’ bricks old size, straight or curved on plan exc 6 metre mean radius in CM 1: 6 complete all as specified and directed. |
| 92 | M & L for Brickwork with sub class ‘B’ bricks in one brick thick honey comb walling, built in CM 1:4 complete all as specified and directed. |
| 93 | M & L for loose filling with broken bricks of gauge 80 to 150mm in sokage pits, sokage wells complete all as specified and directed. |
| 94 | S & F MS rungs of 20mm dia bar etc complete all as specified and directed. |
| 95 | M & L for rendering 15 mm thick on fair faces of brick works masonry or concrete surfaces in CM 1:4 finished the surface even & smooth without using extra cement complete all as specified and directed. |
| 96 | M & L for RCC M-25 Design Mix as in slabs supported on walls, beams & columns in roofs, balconies and in shelves and the like complete all as specified and directed. |
| 97 | S&F cast iron sand cast 100mm size soil waste or vent pipe without ears with cement joint laid in wall/floors/trenches complete all as specified and directed. |
| 98 | M&L for PCC 1:3:6 type C-2 using 40 mm graded stone agg to drain pipe including packing under and haunching against the side of of pipe 150 mm dia (internal) after these are laid in trenches complete all as specified and directed |
| 99 | S&F for providing, lowering and laying HDPE DWCPE (SN8) pipes as per IS : 16098 of 2013, 150 mm ID bore, laid and jointed with and including elastomeric sealing 'O' ring as per manufacturer's instructions including demolition of existing line complete all as specifed and directed. Please Enable Macros to View BoQ information |