| 1 | Laying and Jointing PVC Pipe. Heading |
| 2 | Earth work in excavation in foundation trenches in hard soil (vide classification of soil item - A+B) and disposal of excavated earth as obtained to a distance up to 50M from the foundation trenches all complete as perbuilding specification and direction of E/I.B.C.D. S.O.R. Item No. 5.1.1 + 5.1.2 |
| 3 | Providing coarse clean sand in filling in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including cost of all materials, labours, royaly and taxes all complete as per building specification and direction of E/l. B.C.D. S.O.R. Item No. 5.1.10 |
| 4 | Providing designation 75B one brick flat soling joints filled with local sand including cost of watering taxes, royalty all complete as per building specification and direction of E/I.B.C.D. S.O.R. Item No. 5.6.3 |
| 5 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)B.C.D. S.O.R. Item No. 5.3.1.2 |
| 6 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level. 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size) B.C.D. S.O.R. Item No. 5.3.9.1 |
| 7 | Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete. B.C.D. S.O.R. Item No. 5.3.17.1 |
| 8 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size) B.C.D. S.O.R. Item No. 5.3.10 |
| 9 | Centering and shuttering including strutting, propping etc. and removal of form for Columns, Pillars, Piers, Abutments, Posts and Struts. B.C.D. S.O.R. Item No. 5.3.17.6 |
| 10 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level. 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size)B.C.D. S.O.R. Item No. 5.3.9.1 |
| 11 | Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers.B.C.D. S.O.R. Item No. 5.3.17.5 |
| 12 | Providing designation 75B brick work in Cement Mortar (1:6) in foudation and plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth, curing taxes and royalty all complete job as per building specificition and direction of E/l.B.C.D. S.O.R. Item No. 5.2.6 |
| 13 | Providing and laying damp-proof course 50mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand(zone-III) : 4 graded stone aggregate 20mm nominal size).B.C.D. S.O.R. Item No. 5.3.5 |
| 14 | Providing designation 75B brick work in Cement Mortar (1:6) in superstructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth, curing taxes and royalty all complete job as per building specificition and direction of E/l.B.C.D. S.O.R. Item No. 5.2.14 |
| 15 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size).B.C.D. S.O.R. Item No. 5.3.11 |
| 16 | Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers.B.C.D. S.O.R. Item No. 5.3.17.5 |
| 17 | Centering and shuttering including strutting, propping etc. and removal of form for Weather shade, Chajjas, corbels including edges.B.C.D. S.O.R. Item No. 5.3.17.19 |
| 18 | Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platform.B.C.D. S.O.R. Item No. 5.3.17.3 |
| 19 | Centering and shuttering including strutting, propping etc. and removal of form for Stairs, (excluding landings) except spiral-staircases.B.C.D. S.O.R. Item No. 5.3.17.7 |
| 20 | Providing TMT steel reinforcement 8mm, 10mm, 12mm & 16mm dia bars as per approved design and drawing excluding carriage of M.S bar to work site, cutting, bending end binding with annealed wire with cost of wire removal of rust placing the rods in position all complete as per building specification and direction of E/I.8mm dia Bar -B.C.D. S.O.R. Item No. 5.5.4 : |
| 21 | B.C.D. S.O.R. Item No. 5.5.5 (a) : 10mm dia Bar - |
| 22 | B.C.D. S.O.R. Item No. 5.5.5 (b) : 12mm & above dia Bar - |
| 23 | Providing 12 mm thick cement plaster (1:4) with clean coarse sand of F.M. 1.5 with 1.5 mm cement punning including screening, curing with all leads and lifts of water, scaffolding, taxes and royalty all complete as per specification and direcition of E/l.B.C.D. S.O.R. Item No. 5.7.2 + 5.7.11 |
| 24 | Providing 6mm cement plaster (1:4) in ceiling with clean coarse sand of F.M 1.5 including cost of screening, curing with all leads and lifts of water, scaffolding, taxes and royalty all complete as per building specification and direction of E/I.B.C.D. S.O.R. Item No. 5.7.6 |
| 25 | Providing 12 mm thick cement plaster (1:6) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding, taxes and royalty all complete as per specification and direcition of E/l. B.C.D. S.O.R. Item No. 5.7.3 |
| 26 | Providing 12mm water proof cement plaster (1:3) with clean coarse sand of F.M 1.5 with 5% cico or any other approved water proofing compound including cost of screening, curing with all leads and lifts of water, scaffolding, taxes and royalty all complete as per building specification and direction of E/I.B.C.D. S.O.R. Item No. 5.7.14 |
| 27 | Providing 25mm thick first class patent stone flooring (1:2:4) with stone chips in two layers, bottom layers 19mm thick (1:2:4)with 12mm to 6mm size graded stone chips and top layer 6mm thick (1:2) with 6mm down stone chips, in panels including cost of curing, finishing the surface smooth by rubbing with carborandum stone, taxes and royality with all complete as per building specification and direction of E/I.B.C.D. S.O.R. Item No. 5.6.7 |
| 28 | Providing and fixing fan hook of 16mm dia TMT M.S. bar 1 meter long bent to required size and shape placed in position and fixed in R.C.C. slab/beam at the time of casting all complete as per building specification and direction of E/I.B.C.D. S.O.R. Item No. 5.5.13 |
| 29 | Supplying, Fitting and fixing M.S grill made of 20 x 6mm M.S. flat as per approved design and drawing, properly fabricated with joints continuous fillet welded and finished smooth, hoisting carriage of grill to work site hoisting as per building specification and direction of E/I.B.C.D. S.O.R. Item No. 5.5.12 |
| 30 | Supplying, fitting and fixing collapsible gate of approved size and make properly fabricated with vertical double channels 20 x 10 x 2mm at 100mm centers and braced with M.S. flat diagonals 20 x 3mm with top and bottom rails of T.iron 40 x 40 x 6mm with 38mm dia steel pulleys complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of red lead paint, car riage, hoisting and taxes all complete as per building specification and direction of E/I. B.C.D. S.O.R. Item No. 5.5.14 |
| 31 | Supplying, fitting and fixing 20 guage G.C.I. Sheet gate fitted on M.S. Angle frame of size 60X60X6mm. Including cost of fabrication, providing necessary locking arrangement with haskal and domny duly fixed in P.C.C. (1:2:4) blocks of required size applying a priming red lead paint over steel work, taxes all complete as per drawing specification and direction of E/I.B.C.D. S.O.R. Item No. 5.5.29 |
| 32 | Providing and applying white cement based wall putty of average thiickness 1mm of approved brand and manufacture over the plaster wall surface to prepare the surface even and smooth complete job as per building specification and direction of E/I.D.S.R. Item No. 13.80 |
| 33 | Providing and applying putty of 2 mm thickness of approved brand and manufacture over the plaster wall surface to prepare the surface even and smooth complete job as per building specification and direction of E/I. D.S.R. Item No. 13.26 |
| 34 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade : New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm). D.S.R. Item No. 13.47.1 |
| 35 | Providing two coats of plastic emulsion paint of approved shade and make over a coat of cement primer over new surface including preparing plastered surface by rubbing smooth with pumice stone or fine sand paper, applying putty wherever required, scaffolding washing of floor and taxes all complete as per building specification and direction of E/I. B.C.D. S.O.R. Item No. 5.8.21 |
| 36 | Providing two coat of painting with ready mixed paint of approved shade and make over steel surface including cleaning the surface throughly, scaffolding and taxes all after removing dirt including scales smokes, grease and sand papering including cost of scaffolding and taxes all complete as per building specification and direction of E/I.B.C.D. S.O.R. Item No. 5.8.43 |
| 37 | Earth filling in foundation trenches and plinth in layers not exceeding 150mm thick well watered, rammed, fully compacted and finally dressed with earth obtained from excavation of foundation trenches with a lead of 50m and lift of 1.5m all complete as per building specification and direction of E/l.B.C.D. S.O.R. Item No. 5.1.7 |
| 38 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.B.C.D. S.O.R. Item No. 5.3.8 |
| 39 | Providing 150mm wide brick drain in cement mortar (1:6) with av. 150mm clear depth and 125mm apron including cost of eartwork involved with 75mm cement concrete (1:4:3) over one brick designation 75A flat soling in proper grade and slope at the base the drain duly plastered in C.M. (1:3) with punning over exposed surface all complete as per building specification and direction of E/I. B.C.D. S.O.R. Item No. 5.10.34 |
| 40 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) 110mm dia Single socketed pipes.D.S.R. Item No. 12.41.2 |
| 41 | Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.Single tee with door - 110mmD.S.R. Item No. 12.42.3.2 |
| 42 | D.S.R. Item No. 12.42.5.2 - Bend 87.5° - 110mm |
| 43 | D.S.R. Item No. 12.42.6.2 - Shoe (Plain) - 110mm |
| 44 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required. Group B 1.3.2 |
| 45 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required.2 x 1.5 sq.mm + 1 x 1.5 sq.mm earth wire 1.7.1 |
| 46 | 2 x 2.5 sq.mm + 1 x 2.5 sq.mm earth wire 1.7.2 |
| 47 | 2 x 4 sq.mm + 1 x 4 sq.mm earth wire 1.7.3 |
| 48 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).1.31 |
| 49 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.1.32 |
| 50 | Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 amps \\"C\\" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. 2.18 |
| 51 | Supplying and fixing of following sizes PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm dia 1.21.1 |
| 52 | 25 mm dia 1.21.2 |
| 53 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required. 1 or 2 Module (75mm x 75mm) 1.27.1 |
| 54 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required. 1 or 2 Module (75mm x 75mm)12 Module (135mm x 205mm x 60mm) 1.27.5 |
| 55 | Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.1.25 |
| 56 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)16 way, Single door 2.8.6 |
| 57 | 40 amps, Single pole \\"B\\" series 2.11.2 |
| 58 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.50/63 amps, DP 2.12.7 |
| 59 | Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.80/100 amps 2.15.3 |
| 60 | 125 Amps 2.15.4 |
| 61 | Earthing with copper earth plate 600 mm x 600 mm x 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. (but without charcoal/ coke and salt ) as required.3.6 |
| 62 | Supplying and laying 8 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required.3.7 |
| 63 | Supplying,Installation, testing and commissioning of following size ceiling fan 3 Blades conforming to IS:374:2019, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FR PVC insulated copper wire / conductor suitable for 230V 50Hz, single phase supply etc.complete as 1400mm (56\\") Ceiling Fanrequired. 9.4.2 |
| 64 | Providing and fixing of LED Bulb - 15/16 watt M-856 |
| 65 | S.I.T.C. of following rating surface mounted LED Tube light fitting suitable for 230V, 50Hz, single phase supply etc. complete as required - 20/22 watt LED Tube light9.5.2 |
| 66 | Carriage of materials including loading, unloading, stacking -do- -do- all complete as per specification and direction of E/I.(i) Cement |
| 67 | (ii) Sand |
| 68 | (iii) Bricks |
| 69 | (iv) Steel |
| 70 | (v) Stone Chips |
| 71 | Add. 18% GST |
| 72 | Add. 1% Labour Cess Please Enable Macros to View BoQ information |