| 1 | Excavation in trenches, not exceeding 1.5 metre wide and not exceeding 1. 5 metre in depth; for foundation or for manholes not exceeding 10 Sqm on plan and not exceeding 1.5 metre in depth and getting out in soft/loose soil complete all as specified |
| 2 | Returning filling in, including spreading, levelling, watering and well ramming in layers each not exceeding 25 cm depth in soft/loose soil complete all as specified |
| 3 | Removing surplus spoil to distance not exceeding 50 metre and depositing where directed at level not exceeding 1.5 metre above the starting point complete all as specified |
| 4 | Demolition and breaking up drain pipes (Salt glazed ware, AC or Reinforced concrete pipe & PVC pipe) set in cement mortar for 150 mm dia pipe or less, complete all as specified |
| 5 | S&F 150 mm dia Reinforced concrete pipe Class NP-2 with one collar per length joint with CM 1:1 with spun yarn and tested complete all as specified. Note: Excavation & earthwork shall be measured and paid separately. |
| 6 | S&F for 110 mm dia PVC (SWR) pipe single socketed in any length fixed with suitable adhesives laid in trenches or in floor complete all as specified |
| 7 | All as per Srl item No.06 above but fixed on wall complete all as specified |
| 8 | S&F in repair PVC (SWR) bend for 110 mm bore pipe, any radius jointed with suitable adhesives complete all as specified |
| 9 | S&F for 75 mm dia PVC (SWR) pipe single socketed in any length fixed with suitable adhesives laid in trenches or in floor complete all as specified |
| 10 | All as per Srl item No. 09 above but fixed on wall complete all as specified |
| 11 | S&F in repair PVC (SWR) bend for 75 mm bore pipe, any radius jointed with suitable adhesives complete all as specified |
| 12 | S&F in PVC SWR) 'S' trap of 110 mm bore, complete all as specified |
| 13 | M&L for cement concrete 1:3:6 type C-2 (using 40 mm graged stone aggregate) as in concrete bed to drain pipes of 150mm bore including packing under, and haunching against the sides of pipes after they are laid and tested, complete all as specified |
| 14 | Taking down cement or cement lime plaster of any description from brick or stone walls including raking out joints, hacking for key, scrubbing down with water etc, complete all as specified. |
| 15 | Demolition of brickwork or stone boulder masonry built in cement mortar including all quoins, arches, pillars etc complete all as specified |
| 16 | Demotion of concrete of any description and in any position not otherwise specifically provided for, complete all as specified |
| 17 | Brickwork with sub-class ‘B’(old size) burnt clay bricks straight or curved on plan exc 6 metre mean radius built in cement & sand mortar 1:4 complete all as specified |
| 18 | M&L for rendering 10 mm thick in cement and sand mortar 1:6 on fair faces of brick work or concrete surfaces including finishing the surface even and smooth without using extra cement, complete all as specified |
| 19 | M&L for rendering 15 mm thick using cement and sand mortar 1:4 on fair faces of brick work & cement concrete surfaces including finishing the surface even and smooth without using extra cement, complete all as specified |
| 20 | M&L for PCC, 1:4:8 type D-2 using 40mm graded stone aggregate in foundation, filling and mass concrete complete all as specified. |
| 21 | M&L for PCC, 1:2:4 type B-1 using 20 mm graded stone aggregate as in surface channels, drains and inside the main hole complete all as specified |
| 22 | M&L for providing cement concrete 1:2:4 Type B-1 (using 20mm graded stone aggregate) as in lintels upto 1.5 m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating complete all as specified |
| 23 | M&L for preparation of newly plastered surfaces of wall including cornices, pillasters etc and applying two coats of cement based paint, white or tinted over a coat of alkali resistant primer complete all as specified |
| 24 | Demolition of stone slabs and tiles of any description or thickness in floor, apron etc laid dry and pointed etc., complete all as specified |
| 25 | M&L for 20-25 mm thick sand stone slab as manhole cover complete all as specified |
| 26 | M&L for RCC 1:2:4 type B-1 using 20 mm graded crushed stone aggregate as in cover slab set in CM 1:4, complete all as specified. |
| 27 | S/F mild steel TMT bars 6 to 8mm dia and over cut to length, bend to shape required including cranking, bending and binding with mild steel wire (annealed) not less then 0.9 mm dia, complete all as specified. |
| 28 | M&L for cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished, and forming benching as required, complete all as specified and as directed. (internal dia 150mm) |
| 29 | Demolition of cement concrete (un-reinforced) in ground floors and pavings n.exc 15 cm thickness (below or above GL), complete all as specified |
| 30 | M&L for 40 mm thick cement concrete 1:2:4 type B-1 (using 20 mm graded stone aggrgate) finished even and smooth without using extra cement, complete all as specified |
| 31 | M&L for 75 mm thick cement concrete 1:3:6 Type C-2 (using 40 mm graged stone aggregate) as in plinth protection etc complete all as specified |
| 32 | Dismantling of floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to stores and rubbish off the premises, complete all as specified. |
| 33 | M&L for coloured non skid ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, as in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15 mm thick screed bed or bedding layer of CM 1:6, complete all as specified |
| 34 | M&L for coloured glazed ceramic tiles of size 300mm x 200mm x 7mm thick on vertical surface such as skirting dado etc including 10mm thick rendering in CM 1:4, set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified |
| 35 | S&F GI tubing medium grade ISI marked with all fitting and fixed to walls & ceilings or laid in floors, bore of pipe 15 mm including taking up or down the existing unserviceable GI tubing, complete all as specified |
| 36 | S & F GI tubing medium grade ISI marked with all fitting and fixed to walls & ceilings or laid in floors, bore of pipe 20 mm including taking up or down the existing unserviceable GI tubing, complete all as specified. |
| 37 | Disconnecting existing tanks of capacity exc 250 litres & n exc 500 litres, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position after cleaning and removing all scale and dirt, etc. from tanks and from mouths of circulating pipes, etc. complete all as specified |
| 38 | Dismantling old unserviceable water tanks and S&F Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) of capacity 500 litres, white colour, triple layered, hoisted and fixed in position & including 20 mm brass ball valve, complete all as specified |
| 39 | Dismantling old unserviceable water tanks and S&F Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) of capacity 1000 litres, white colour, triple layered, hoisted and fixed in position & including 20 mm brass ball valve, complete all as specified |
| 40 | S&F in repair Vitreous China squatting pan “Orissa” pattern, size 580x440mm, white, with integral foot rests and 'P' or 'S' trap (excluding flushing cistern and flush pipe), including connection to trap, and to flushing pipe, anti-syphonage pipe, etc. including making good to floor complete all as specified.Note: The disturbed surface of floor shall be made good as per existing specification without any extra cost to the Govt. |
| 41 | S&F in repair vitreous china wash down water closet pan (pedestal pattern) white, including all required fittings complete all as specified. |
| 42 | S&F in repair wash hand basin vitreous china, size 550 mm x 400 mm, white, flat back, including CI brackets, pillar tap fixed to 15mm bore pipe, long body fancy type cast copper alloy with capstan heads, chromium plated screwed down high pressure, with ot without lettered 'Hot' or 'Cold' with long screwed shanks and fly nuts, CP waste fitting for waste pipe 32 mm dia with brass coupling, center hole CP grating including pinning in ends of brackets etc, complete all as specified |
| 43 | S&F in repair PVC 10 ltrs , valveless, syphonic action type, flushing cistern, white, low level, with inlet, ball valve, float and handle, including 32 mm bore PVC flush pipe brackets complete all as specified |
| 44 | S&F in repair PVC connection 15 mm size with PTMT nuts of length 450 mm, complete all as specified |
| 45 | S&F plastic water closet seat, white, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device, complete all as specified |
| 46 | S&F in repair Bib tap, cast copper alloy chromium Plated fancy type/ long body with crutch or butterfly handle, screwed down, suitable for 15mm nominal bore iron pipe screwed for iron or brass ferrule and fixed, complete all as specified. |
| 47 | S&F in repair 15 mm bore Stop valves, fancy type chromium plated screwed down high presure, with crutch of butterfly handle, screwed both ends for iron pipe or for unions and fixed, complete all as specified |
| 48 | S&F in repair pillar tap, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with long screwed shank and fly nuts, with or without lettered \\"Hot\\" or \\"Cold\\" suitable for 15 mm nominal bore iron pipe, screwed for iron pipe and fixed complete all as specified |
| 49 | Taking down chowkhats or frames with shutters (without taking off shutters from the frames) of size n. exc 1.5 Sqm each complete all as specified. |
| 50 | S & F factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of M.S tubes for top & bottom rails. MS frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet stip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement as per specification & drawing shown in SSR Pt-I. |
| 51 | S & F solid PVC door frame of size 50 mm x 47 mm made out of 5 mm plain colour PVC sheet reinforced with MS Square tube fixed in opening as per specification & drawing shown in SSR Pt-I. |
| 52 | S & F of Butt hinges, 100mm size extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed type B-21 complete all as specified. |
| 53 | S&F aluminium, anodised, 150mm long barrel tower bolts of extruded section and fixed complete all as specified |
| 54 | S&F aluminium, anodised handle 150mm size cast type anodised complete all as specified |
| 55 | Cleaning/removing blockage of sewer line (SGSW/RCC/CI) of dia 100 mm including gully traps, grease traps etc.by removing all sludge, foreign materials and other deposit whatsover competely and making the line free from all obstacles of any description or in any position by roding, by pressure pump of any type or by using any mechanical equipments, manually or by puncher of sewage line and repair the same if required including taking off and re-fixing manhole covers including testing the flow of sewar line evenly, smoothly by filling water and removing the silt/sludge in covered van/trolly outside the MD land complete all as specifiedNote : The sewage line cleared shall be measured one time only and the contractor shall be responsible to clear any subsiquent blockage occured during entire contract period. |
| 56 | All as per Srl Item No 55 above but size of sewage line 150 mm dia complete all as specified |
| 57 | De-watering from septic tanks/soakage wells of any size and any depth by suitable pumps and also removing of all wastes, semi solid or liquid of any description to outside MoD land complete all as specified |
| 58 | De-sludging of manhole sludge (dry/wet), n exc. 1.50 m depth, individual manhole, desludging of septic tank & soakage well of any size, sludge removal manually including disposing of sludge by covered vehicle to a distance exc 500m but n.exc 3000 m & burried in excavated pit of adequate size including excavation and covering with earth from the existing septic tank of any depth, any capacity, in foul conditions, including taking & placing in position the manhole covers of any description, removal of sludge & solid contents to any place outside defence land and depositing complete all as specified |
| 59 | De-sludging of manhole sludge (dry/wet) & septic tank and soakage well, exceeding 1.50 m depth, individual manhole, desludging of septik tank/soakage well of any size, sludge removal manually including disposingl of sludge in covered vehicle to a distance exc 500 m but n.exc 3000 m & burried in excavated pit of adequate size including excavation and covering with earth from the existing septic tank of any depth, any capacity, in foul conditions, including taking & placing in position the manhole covers of any description, removal of sludge & solid contents to any place outside defence land and depositing complete all as specified |
| 60 | Cleaning/removing blockage of WC, bath, kitchen, WHB, Gully Trap, includding P or S-Traps of any description, by rodding, pressure pumps of any description etc. by removing all sludge, foreign materails and other deposits whatsoever completely (working in foul condition with taking precautionary measures equipment as required or applicable and working on all working days including sunday) complete all as specified |
| 61 | Provn of 10 users septic tank designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, Vent shaft, connection etc., complete as per TD No. CEJZ/2002/TD/S-2. |
| 62 | Provn of Sokage well, excavation in ordinary soil, foundation in PCC 1:3:6 wall of honey combed masonry with top ring of M-25 concrete, including intercepting chamber, screen chamber brick work in CM 1:6, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size 1.2 meter dia and 3.0 meter effective depth complete all as per TD No. : CEJZ/2004/TD/S-35. |
| 63 | M & L for framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes, barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks and similar work conforming to Fe.290.Gde-E-165, complete all as specified. |
| 64 | S&F welded steel wire fabric ,weight n. exc 4.00 kg/sq. m fixed to steel members complete all as specified. |
| 65 | M&L for preparation of new steel and iron surface of any description and applying 2 coats of syntheltic enamel paint over a coat of red oxide primer complete all as specified |
| 66 | M&L for preparation of new steel and iron surface of any description and applying 2 coats of syntheltic enamel paint over n. exceeding 10 cm in width or girth when unconnected with other painting or when painted in a different tint complete all as specified |
| 67 | M&L for 100 mm thick Cement concrete (1:4:8) type D-2, using (40mm graded stone aggregate) as in sub floors/sub bases etc. complete all as specified Please Enable Macros to View BoQ information |
| 68 | M&L for 100 mm thick Cement concrete (1:4:8) type D-2, using (40mm graded stone aggregate) as in sub floors/sub bases etc. complete all as specified Please Enable Macros to View BoQ information |