| 1 | Disconnecting and taking down repairable LED type street light fitting of any type and capacity and make from existing 9 metre /11 metre pole for checking to find out the defects cleaning the glass and prefix cover, repair/replacement of spare parts including necessary wiring etc for making the fitting in serviceable condition and refixing in original position, testing etc complete all as specified and directed.Note : (i) The Spare parts will be measured and paid separtely.(ii) All type of T&P for repairing of street light should be provided by the contractor at own arrangememt. |
| 2 | Supply only LED driver 240Volt 50Hz for 45 to 70 watt LED fittings complete all as specified and directed Make - Bajaj/Philips/Crompton. |
| 3 | Supply only LED driver 240Volt 50Hz for 75 to 90 watt LED fittings complete all as specified and directed. Make - Bajaj/Philips/Crompton. |
| 4 | Supply only LED surge arrester 240Volt 50Hz, 5 KV for 45 to 70 watt LED fittings complete all as specified and directed.Make - Bajaj/Philips/Crompton. |
| 5 | Supply only LED surge arrester 240Volt 50Hz, KV for 75 to 90 watt LED fittings complete all as specified and directed.Make - Bajaj/Philips/Crompton. |
| 6 | Disconnecting and taking down repairable LED type street light fitting from High Mast Light of any type and capacity and make from existing 15 mtrs/16 mtrs high mast pole by taking down the LED light by roatating through Electric/Mechanical Mechanism for checking to find out the defects cleaning the glass and prefix cover, repair/replacement of spare parts including necessary wiring etc for making the fitting in serviceable condition and refixing in original position, testing etc complete all as specified and directed. Note : (i) The Spare parts will be measured and paid separtely.(ii) All type of T&P for repairing of High mast light should be provided by the contractor at own arrangememt. |
| 7 | Supply only LED driver 240Volt 50Hz for 120 to 150 watt LED fittings complete all as specified and directed Make - Bajaj/Philips/Crompton. |
| 8 | Supply only LED surge arrester 240Volt 50Hz, 5 KV for 120 to 150 watt LED fittings complete all as specified and directed. |
| 9 | Retightening of Loose/ Disconnected Connection of LED type street light fitting of any type and capacity and make on existing 9 metre /11 metre pole for Cleaning of carbon from connecting wire and joint the connection as per existing Connections and refixing in original position,etc complete all as specified and directed. Note : (i) All type of T&P for Connection Checking and tightening of connection of street light shall be provided by the contractor at own arrangement. |
| 10 | Supply and laying XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area of size 4 core 16 sqmm including taking out old u/s cable complete all as specified and directed. |
| 11 | Supply and laying XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area of size 4 core 10 sqmm including taking out old u/s cable complete all as specified and directed. |
| 12 | Supplying and fixing 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections of size 10 Sqmm 2 core including out old u/s service wire complete all as specified and directed. |
| 13 | Supplying and fixing 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections of size 6 Sqmm 2 core including out old u/s service wire complete all as specified and directed. |
| 14 | S&F cable PVC insulated sheathed twin core stranderd Aluminium conductor of size 4.0 Sq mm for connection of security /Street lights complete all as specified and directed. |
| 15 | Excavation in trenches n. exc 1.5mm wide and n.exc 1.5m deep for foundation of poles/stays/cable etc and getting out in soft /loose soil complete all as specified and directed by Engr-in-Charge. |
| 16 | Excavation in trenches exc 1.5mm wide and exc 1.5m deep for foundation of poles/stays/cable etc and getting out in soft /loose soil complete all as specified and directed by Engr-in-Charge. |
| 17 | Returning , filling in and incl spreading, levelling watering and well ramming in layers each n.exc 25cm thick in soft/loose soils complete all as specified and directed. |
| 18 | Removing surplus soil to a distance n.exc 50 mtr and depositing where directed at a level n.exc 1.5 mtr above the starting point etc complete all as specified and directed. |
| 19 | M& L for Sand cushioning to under ground cable in trenches/existing cable trenches/ducts in layers of 8 cm deep before laying the cable and 15 cm deep after laying and stretching the cable complete all as specified and directed by Engr in charge. |
| 20 | Supply and laying well burnt, sub class 'B' brick old size for cable protection complete all as specified and directed. |
| 21 | M&L for cement concreted (1:4:8) type D-2 using 40 mm graded stone aggregate as in foundation of poles filling and mass concreting complete all as specified and directed. |
| 22 | M&L for cement concreted (1:3:6) type C-2 using 40 mm graded crushed stone aggregate in foundation of pole/ stay assembly/feeder pillar box/LT panel,etc, incl necessary form work and fair finsh to exposed surfaces without using extra cement etc, complete all as specified and directed. |
| 23 | M&L Cement concreted (1:2:4) type B-1 using 20 mm graded stone aggregate as in foundation of electric poles/struts/ etc including necessary form work, fair finished surfaces without using extra, complete all as specified and directed. |
| 24 | S&F in replacement of Factory made sheet metal encloser SPN single door type made out of CRCA sheet IP 65 protection 2 way 240 v dust and vermin proof includind clamps, nut-bolts for fixing of fixing on pole, complete all as specified and directed. |
| 25 | S&F MCB single pole neutral 240 volts, 40 Amps, 10 KA, 'C' series, complete all as specified and directed. |
| 26 | S&F MCB single pole neutral 240 volts, 63 Amps, 10 KA, 'C' series,complete all as specified and directed. |
| 27 | Dismantling & taking out old damaged PCC pole of any size and removing from site of work complete all as specified and directed. |
| 28 | Supply and fixing LT Pre-stressed concrete pole 9.0 metres long of cross section 102 mm x 172 mm at top and 102 mm x 279 mm at bottom class 10 complying with requirement of IS 1678-1978 incl painting of poles with two coats of synthetic enamel paint/over a coat of primer in black and white strips upto 1.5 mtr height from top of PCC as directed (PCC and earth work shall be measured and paid separately). complete all as specified and directed |
| 29 | Supply & fixing of LED Street light 70 Watt made up of pressure die cast housing with toughned glass Aesthetically designed roadway luminiare with excellent thermal management IP 66 protection including taking down old U/S fittings of any type complete all as specified and directed. |
| 30 | Supply and fixing LED street light fitting 90 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection with impact resistance of 1K and 10KV external SPD including taking down old U/S fittings of any type complete all as specified and directed. |
| 31 | Supply and fixing LED flood light 120 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP- 66 protection, with impact and corrosion resistant complete with driver and lamp. including taking down old U/S fittings of any type complete all as specified and directed. |
| 32 | Supply & fixing 3 core 1.5 sqmm PVC insulated and FR PVC round sheathed copper conductor flexible 1100 volts for connection from Junction Box to street light fittings complete all as specified and directed. |
| 33 | Material & labour for boring hole under the road/payment/ hard standing upto 100 mm Bore Pipe not less than one metre below ground level complete all as specified and directed. |
| 34 | Supply, Installation and Fixing LT Cable junction box shall be made out of Thermoplastic Polycarbonate and size should be not less than 200mm x 160mm x 98 mm(upto Cable Size 16/25sq.mm). The Polycarbonate JB shall be environment friendly, recyclable, halogen & silicon free, anti acid & anti corrosive,IP 65 in accordance with IEC 60529,Weatherproof UV-resistant, rainwater-proof, temperature-resistant. The gasket material of JB shall be Polyurethane and the gasket shall be internally embedded. The Junction Box shall be complies with requirements of the standards IEC 60998 - 1, IEC 60670 - 22 & IEC 60670 - 2 - 5. The JB Colour according to RAL 7035. The Junction Box shall be with four side screw and they will be sealable without any accessories. The manufacturer of Junction Box / Enclosure shall be submit a copy of IEC Certificate . For better safety the Polycarbonate enclosure and shall be fire retardant & self - extinguishing in accordance with IEC 60695 - 2 - 11, DIN VDE 0304 Part - 3, UL Subject 94 for Flammability V-2. It should be tested at Glow Wire test for 960 degree Centigrade & Terminal Stud with Current Carrying Capacity upto 63Amps. The impact strength of Polycarbonate enclosure / boards i.e. the Degree of protection against mechanical load shall be in accordance with EN 50298 - 98 for IK 08 including one No. 4 pole connector including MCB SP, 6 Amp and Chromium plated clamps, suitable Cable Gromets and nut bolts and complete all accessories. Make : Cat Part :- KM 9250 of Hensel/Siemens/Schneider/ABB. Manufacturer should submit routine test certificate of CJB/PJB |
| 35 | S&F GI Bracket for street light fitting bend to shape made out of GI pipe light grade 40mm bore upto 1.2 mtr long etc complete with MS clamps duly painted with two coat of aluminum paint with nuts/bolts/washers for fixing arrangement to pole /wall complete all as specified and directed. |
| 36 | M&L painting to steel tubular pole of size 9 metre / 11 metre hight with two coats of aluminium paint including preparation of old painted surface and including wiriting pole No. complete all as specified and directed .complete all as specified and as directed |
| 37 | Supply and laying GI pipe 40 mm bore /Size \\"light grade \\" for cable protection including taking out old/broken/rusty GI pipe with MS clamps complete all as specified and directed. Please Enable Macros to View BoQ information |