| 1 | M&L for dismantling posts or struts (wood, steel or R.C.C.) embedded in concrete, brick work, masonry, etc. any section, including taking out embedded portion and making good disturbed ground complete all as specified. |
| 2 | Excavating in post holes (or similar holes) each n exc 0.5 cum, getting out in soft soil, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, complete all as specified. |
| 3 | M/L PCC 1:4:8 type D2 using 40 mm graded stone aggregate as in foundation filling and mass concrete for fixing RCC/ any fencing posts complete all as specified. |
| 4 | M&L for mild steel work in hand rails, half round or other stock section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors,balusters,nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe 410-0 or FE 310-0 complete all as specified. |
| 5 | M&L for mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exc 5cm long but n exc 10cm long complete all as specified. |
| 6 | Dismantling fencing wire mesh, any type complete all as specified. |
| 7 | Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provision of binding wire complete all as specified. |
| 8 | Supply only Chain link mild steel galvaised fencing, any size or type complete all as specified. |
| 9 | M&L Mild steel bars 10mm dia and over,cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mmdia or securing with clips quality conforming to complete all as specified. |
| 10 | M&L Galvanised, 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed (each line wire to be measured) fixed in repair complete all as specified. |
| 11 | Painting to new steel or steel based surfaces of any description, not otherwise described over 10cm width or girth including preparation of surfaces, priming with red oxide zinc chrome primer (one coat) & finishing with two coats of synthetic enamel paint complete all as specified. |
| 12 | Demolition of cement concrete (un-reinforced) in ground floors and pavings n.exc 15 cm thickness (below or above GL) complete all as specified. |
| 13 | Demolition of brickwork or stone boulder masonry in portions built in cement mortar including all quoins, arches, pillars etc complete all as specified. |
| 14 | M & L for PCC (1:3:6) type C-2 using 40 mm graded stone aggregate in foundation filling and mass concrete complete all as specified. |
| 15 | M&L for Brickwork with subclass `B' bricks, straight or curved on plan exc 6m mean radius, built in cement mortar (1:6) complete all as specified. |
| 16 | Taking down cement or cement lime plaster of any description on brick or concrete surfaces including raking out joints, hacking for key, scrubbing down with water etc complete all as specified. |
| 17 | M&L for rendering 15mm thick in cement mortar (1:4) on fair faces of brick masonry or concrete surfaces of walls,using water proofing compound as per manufacture's instruction and finished even & smooth without using extra cement complete all as specified.Note:- WPC to be measured and paid for separately |
| 18 | M & L for PCC (1:3:6) type C-1 using 20 mm graded stone aggregate in surface channel complete all as specified. |
| 19 | Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc, complete all as specified.Note : Inner girth only measured. |
| 20 | Supply only integral waterproofing compound complete all as specified. |
| 21 | M&L for preparation of newly plastered surface and applying two coats of cement base paint of approved shade over a coat of primer on walls complete all as specified. |
| 22 | M&L forProviding, cement concrete type B1 1:2:4 (Using 20mm graded stone aggregate)in roof kerbs or mud stops, rounded or chamfered on edges, lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, complete all as specified. |
| 23 | M&L for 25 mm thick, sand for filling under floors, spreading and levelling in layers including watering and consolidation complete all as specified. |
| 24 | M&L for 60 mm thick, machine pressed precast concrete interlocking paver block with grey cement and no pigment of any shape and size over and including 100 mm thick PCC 1:4:8 type D2 using (40mm graded stone aggreate) as approved by GE, confirming to IS 15658-2006, M-35 Grade, complete all as specified. |
| 25 | M&L for machine factory made PCC block (1:2:4) type B1 using 20 mm graded stone aggregate, as in kerb stone of size 300 x 300 x 150 mm set in cement mortar (1:4), complete all as specified. |
| 26 | M/L for 75mm thick cement concrete type D2 1:4:8 (using 20mm graded stone aggregate) as in sub base complete all as specified.Note : For rising existing floor as low laying area. |
| 27 | M/L for heavy duty paving tiles of size 300mmx300mmx10mm thick exterior grade having with water absorption less than 0.5% and conforming to IS:15622 of approved make in all colours and shades for outdoor floors such as foot path,court yard etc laid over and including 15mm thick screed bed of CM 1:6 for laying floor finishes including grouting the joints with white cement mixed with matching pigments etc,complete all as specified. |
| 28 | Dismantling asbestos cement/galvalume/fibre glass (corrugated or semi corrugated) sheets in roof coverings, complete all as specified. |
| 29 | Dismantling timber scantlings as in fillets, rails, posts, rafters, purlins, etc under 40 Sqcm in section from unframed work, complete all as specified. |
| 30 | M&L Framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; Flat iron,barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 410-0 or Fe 310-0 hung as gates, including pintle hinges, stops, hand-made sliding bolts, etc. complete all as specified. |
| 31 | S&F welded steel wire fabric ,weight n. exc 4.00 kg/sq. m fixed to steel members complete all as specified. Please Enable Macros to View BoQ information |