| 1 | Excavation in trenches not exceeding 1.5m wide and not exceeding 10 Sq.m on plan area and not exceeding 1.5m deep in any type of soil, for foundation etc., or for laying of cable / GI Pipe, shafts, wells, cesspits, manholes, pier holes, etc., complete all as specified. |
| 2 | M&L for PCC 1:4:8 type D2 (using 40mm graded Granite stone aggregate) as in foundation, filling, mass concrete etc., complete all as specified and as directed. |
| 3 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick of excavated soil, as in any type of soil, complete all as specified. Note: A deduction of 10% shall be made from total computed volume of filling to cater in bulk irrespective of machinery used for ramming. |
| 4 | Removal of excavated material [Soil] to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point, complete all as specified. |
| 5 | S&F Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick (TFT) of an colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws, complete all as specified and as directed. |
| 6 | S&F Rolled mild steel roof trusses (framed) trussed purlins, rafters, struts (beam, tee, angle channel or flat sections including distance pieces, cleats etc. conforming to grade Fe 410-W Gde E - 250 quality 'B', complete all as specified and as directed. |
| 7 | M&L for applying two coats of synthetic enamel paint with and including preparation of new steel and steel based surface of any description of size not exceeding 10cm width or girth, complete all as specified and as directed. |
| 8 | Supply, laying, testing and commissioning of LT XLPE insulated, screened with extruded PVC inner sheathed, PVC bedded, galvanised steel strip armoured electric power cable [heavy duty] of size 4.0core x 35.0Sqmm, with stranded aluminium conductor, 1100 volts grade, suitable for earthed system with and including cable glands, ferrules and connected accessories, laid in trenches or ducts or through the pipe etc., complete all as specified. Note: Necessary excavation & earth work, brick protection & sand cushioning shall be measured and paid separately under respective items. |
| 9 | Supply, laying, testing and commissioning of LT XLPE insulated, screened with extruded PVC inner sheathed, PVC bedded, galvanised steel strip armoured electric power cable [heavy duty] of size 4.0core x 25.0Sqmm, with stranded aluminium conductor, 1100 volts grade, suitable for earthed system with and including cable glands, ferrules and connected accessories, laid in trenches or ducts or through the pipe etc., complete all as specified. Note: Necessary excavation & earth work, brick protection & sand cushioning shall be measured and paid separately under respective items. |
| 10 | Supply, laying, testing and commissioning of LT XLPE insulated, screened with extruded PVC inner sheathed, PVC bedded, galvanised steel strip armoured electric power cable [heavy duty] of size 4.0core x 16.0Sqmm, with stranded aluminium conductor, 1100 volts grade, suitable for earthed system with and including cable glands, ferrules and connected accessories, laid in trenches or ducts or through the pipe etc., complete all as specified. Note: Necessary excavation & earth work, brick protection & sand cushioning shall be measured and paid separately under respective items. |
| 11 | Supply, laying, testing and commissioning of LT XLPE insulated, screened with extruded PVC inner sheathed, PVC bedded, galvanised steel strip armoured electric power cable [heavy duty] of size 4.0core x 10.0Sqmm, with stranded aluminium conductor, 1100 volts grade, suitable for earthed system with and including cable glands, ferrules and connected accessories, laid in trenches or ducts or through the pipe etc., complete all as specified. Note: Necessary excavation & earth work, brick protection & sand cushioning shall be measured and paid separately under respective items. |
| 12 | Supply, laying, testing and commissioning of LT XLPE insulated, screened with extruded PVC inner sheathed, PVC bedded, galvanised steel strip armoured electric power cable [heavy duty] of size 3.5core x 150.0Sqmm, with stranded aluminium conductor, 1100 volts grade, suitable for earthed system with and including cable glands, ferrules and connected accessories, laid in trenches or ducts or through the pipe etc., complete all as specified. Note: Necessary excavation & earth work, brick protection & sand cushioning shall be measured and paid separately under respective items. |
| 13 | Supply, laying, testing and commissioning of LT XLPE insulated, screened with extruded PVC inner sheathed, PVC bedded, galvanised steel strip armoured electric power cable [heavy duty] of size 3.5core x 120.0Sqmm, with stranded aluminium conductor, 1100 volts grade, suitable for earthed system with and including cable glands, ferrules and connected accessories, laid in trenches or ducts or through the pipe etc., complete all as specified. Note: Necessary excavation & earth work, brick protection & sand cushioning shall be measured and paid separately under respective items. |
| 14 | Supply, laying, testing and commissioning of LT XLPE insulated, screened with extruded PVC inner sheathed, PVC bedded, galvanised steel strip armoured electric power cable [heavy duty] of size 3.5core x 50.0Sqmm, with stranded aluminium conductor, 1100 volts grade, suitable for earthed system with and including cable glands, ferrules and connected accessories, laid in trenches or ducts or through the pipe etc., complete all as specified. Note: Necessary excavation & earth work, brick protection & sand cushioning shall be measured and paid separately under respective items. |
| 15 | M&L for Dry & clean tibba river sand cushioning in two layers, first layers of 80mm thick before laying of cable and second layer of 150mm thick after laying of cable, levelled and punned down to a depth of 100mm above the top of the upper-most cable, for cable protection in trenches, complete all as specified and as directed. Note: The punned down thickness shall be measured for payment. |
| 16 | Supplying and laying reinforced precast concrete cable cover, Class LV, Type I, flat, size 250mm x 150mm x 40mm, complete all as specified and as directed. |
| 17 | S&F Hot dip Galvanised perforated cable tray with cover for fixing XLPE cables at various places to accommodate the cables for MCBs, Panel etc of size not less than 150mmX50mm, made with 1.2mm thick GI sheet with necessary bends, D clamps, angles, supports for fixing etc., complete all as specified and as directed. |
| 18 | Supply and laying DWC HDPE Pipe 100mm dia, with ISI marked (IS 14930 Part-1&2), laid in trenches / floors & fixed on wall/ pole with and including necessary fittings such as bends, sockets & other connected accessories etc for laying of electric cables / road crossings etc., complete all as specified. |
| 19 | Supply and laying DWC HDPE Pipe 50mm dia, with ISI marked (IS 14930 Part-1&2), laid in trenches / floors & fixed on wall/ pole with and including necessary fittings such as bends, sockets & other connected accessories etc for laying of electric cables / road crossings etc., complete all as specified. |
| 20 | S&F LT straight through cable jointing kit, heat shrink type joint for 1.1KV (Earthed) grade cable with jointing material and accessories, suitable for 4/3.5 core XLPE armoured aluminium conductor cable of size 16sqmm to 50sqmm, complete all as specified. |
| 21 | S&F Electric astronomical timer control panel, cubical type, for out door use, dust & vermin proof wall mounted type, made out of CRCA steel sheet with timer switches type 16Amp, 3 pole, 230 Volt, Analog time switch with complete accessories, fixed on pole for switch on/off and control the street light timings including testing, complete all as specified and as directed. |
| 22 | Supplying, Installation, Testing & Commissioning of Flood Light 200Watt, thermal management in multiple optics, powder coated pressure die cast aluminium body with built in driver as with Driver efficiency >85%, 230 Volt, AC power factor at full load >85, as per IEC 61000-4-5, lenses for beam angle >120deg, fixture shall be of relevant BIS standard with system lumen efficacy ≥130 lm/Watt, IP 66 protection, output and all testing as required for LED fixtures as per BIS, complete all as specified. |
| 23 | S&F GI pipe light grade pipe 50mm dia for cable protection, laid in trenches /pole / walls / road etc., complete all as specified. |
| 24 | Supplying, Installation, Testing & Commissioning of maintenance free chemical earthing of dual pipe technology of 3m long with 88mm outer pipe dia & inner pipe dia 48mm, the pipes are properly galvanised for 80-120 micron and wall thickness of inner pipe 3mm and 2mm of outer pipe, with additional copper coating on outer surface, with terminal for connection of 75mm x 6mm with 2 holes of 14mm dia, fast Electrode duly filled with highly conductive material with sealing at both ends with lead terminal of 75mm x 6mm at top along with 2 bags of 25 Kgs each of earth enhancing compound, chemical compound be tested and certified by any NABL accredited / BIS accredited laboratory of ISO 9001 and 14001 certified, earth enhancing compound be tested referring to protocol IS 1350 and IEC 62321/111/54/CDV, ph value of compound should be 7-8 and content of mercury and hexa chromium should be below detection level, electrode should be tested for salt spray test as per BIS 117-09 for corrosion for minimum 500 Hrs, duly tested and certified by CPRI Govt of India for a min short circuit current of 42k amp for 1 Sec with initial pick of 8.2 K amp connected to copper strip 20mm x 3mm thick earth strip by means of bolts, nuts, check nuts and washers of copper with 40mm dia medium grade Gl pipe as a protection up to 7.5m long and RCC pit with cover and connected to earthing test point and including testing on completion, complete all as specified and as directed. |
| 25 | Supplying, Installation, Testing & Commissioning of Galvanized Steel High mast light 12.50m height in two section, mast shaft with hot dip galvanized, suitable for wind velocity of 47m/sec and soil bearing capacity of 20 TON/Sqm as per IS-1944(Part-5), 3mm section thickness with top 150mm dia and bottom 340mm dia, suitable for 08 lantern symmetrically fitted along with their control gear and having two point suspension system with stainless steel wire rope of 6mm dia, 97/19 gauge and double drum winch with luminaire mounting arm, pulley assembly, galvanised carriage arrangement for 8 lights, 3 phase integral power tool with motor for lifting and lowering, lightning arrester spike, with foundation bolts manufactured from special steel along with nuts, washers, anchor plates, control panel with control cable & switch, outdoor standard feeder pillar (timer panel) with suitable timer & control switch gear, 32A TPN MCB incomer, single dial time switch, 25A TP Contactor for automatic operation of luminaries, power tool control with 2 Nos Contacts and raise lower push button, switch gears and templates, with necessary coper cable one set 5 core x 2.5sqmm, GI junction box, all accessories, including excavation, earth work, RCC M25 foundation as per OEM recommendations, complete all as specified and as directed. Note: Light fittings will be measured and paid for separately. |
| 26 | S&F Factory made epoxy powder coated Sheet metal enclosure Vertical TPN DB, 6 ways (VTPN MCB DB) with IP 43 protection, double door, sheet steel phosphetised powder painted with 200amps rated copper busbar 415Volt, with 1.5 Sq. mm copper PVC sheathed cable for earth continuity and suitable for having MCCB’s/MCBs, complete all as specified and as directed. |
| 27 | S&F MCCB, 4pole, 125 Amps, 415Volts, thermal magnetic, Ics=100% Icu, 16kA current rating conforming to IEC-60947-II along with spreader incl Phase Barreir to be fixed in distribution board, complete all as specified. |
| 28 | S&F Factory made epoxy powder coated sheet metal enclosure for DBs (Fixed flush to the wall), TPN, 415 volt, 4 Way, double door, IP-42 protection with 200Amp rated copper bus bar 415Volt, and 1.5 Sq. mm copper PVC sheathed cable for earth continuity and suitable for having MCB’s, complete all as specified. |
| 29 | S&F MCB SP 06 to 32Amp, 10kA, 230Volt, B curve with necessary connecting up in MCB DB, testing and commissioning, complete all as specified and as directed. |
| 30 | S&F MCB TPN 40 to 63Amp, 10kA, 230Volt, B curve with necessary connecting up in MCB DB, testing and commissioning, complete all as specified and as directed. |
| 31 | S&F MCB TPN 06 to 32Amp, 10kA, 230Volt, B curve with necessary connecting up in MCB DB, testing and commissioning, complete all as specified and as directed. |
| 32 | S&F Modular switch 1 way 5/6Amp, 1 Module, 240 Volts, complete all as specified and as directed. |
| 33 | S&F Modular switch 1 way 15/16A, 1 Module, 240 Volts, complete all as specified and as directed. |
| 34 | S&F Modular cover plate with frame, 4 module, fixed with screws, complete all as specified. |
| 35 | S&F Modular cover plate with frame, 6 module, fixed with screws, complete all as specified. |
| 36 | S&F Modular PVC surface Box 4 module, fixed with screws, complete all as specified. |
| 37 | S&F Modular PVC surface Box 6 module, fixed with screws, complete all as specified. |
| 38 | S&F Sheet metal clad enclosure with a 3 pin and earth plug & socket 32Amp, 3P+N+E type, with and including one TPN MCB 32Amp, 10kA, C series, 240Volt with connections, complete all as specified and as directed. |
| 39 | S&F Heavy duty PVC Casing & capping of size 50mm x 20mm confirming to IS 14927 (part-II), with and including all accessories, elbow, tees, bends etc., as required at site, complete all as specified. Note: One runs of casing & one run of capping shall be measured as one unit. |
| 40 | S&F Heavy duty PVC Casing & capping of size 100mm x 50mm confirming to IS 14927 (part-II), with and including all accessories, elbow, tees, bends etc., as required at site, complete all as specified. Note: One runs of casing & one run of capping shall be measured as one unit. |
| 41 | M&L for Circuit / Sub main wiring with Two runs of 4.0Sqmm PVC FRLSH insulated copper conductor cable, single core multi stranded 1100Volt along with one run of 4.0Sqmm as earth wire, drawn through and including heavy duty PVC casing & capping of suitable size with accessories, complete all as specified and as directed. Note: Two runs of cable, one run of earth wire and one run of casing & capping shall be measured as one unit. |
| 42 | M&L for Circuit / Sub main wiring with Two runs of 6.0Sqmm PVC FRLSH insulated copper conductor cable, single core multi stranded 1100Volt along with one run of 6.0Sqmm as earth wire, drawn through and including heavy duty PVC casing & capping of suitable size with accessories, complete all as specified and as directed. Note: Two runs of cable, one run of earth wire and one run of casing & capping shall be measured as one unit. |
| 43 | M&L for Circuit / Sub main wiring with Four runs of 6.0Sqmm PVC FRLSH insulated copper conductor cable, single core multi stranded 1100Volt along with Two run of 6.0Sqmm as earth wire, drawn through and including heavy duty PVC casing & capping of suitable size with accessories, complete all as specified and as directed. Note: Four runs of cable, Two runs of earth wire and one run of casing & capping shall be measured as one unit. |
| 44 | S&F LT Panel as per IEC 61439, Outdoor type, floor mounted free standing dust and vermin proof panel / DB with IP-55 protection, CPRI approved OEM, frame fabricated out of 40mmx40mm x 4mm MS angle iron, made with 3.15mm thick CRCA sheet for entire outer panel and 1.6mm thick CRCA sheet 40mmx4mm MS flat Iron for inner compartments with separate cubicle chamber with cable alley with minimum 300mm width for installation / connecting switchgears with the main bus bar using aluminium bus link or copper conductor flexible wires suitable for switch rating and connecting outgoing terminals of the switchgear with terminal blocks of appropriate current rating using flexible copper wires duly terminated by cable lugs and thimbles, MS surfaces epoxy based powder coated, shade as approved over 2 coats of red oxide primer, surfaces pre-treated in seven tank process for de-greasing, de-rusting & Phosphated, panel having front and rear opening and provision for installation of separate cable alleys, all MCCBs must be have thermal magnetic relrase, busbar chamber and switchgear compartments, provision in cable alleys for bottom cable entry for incoming & outgoing cables, fixing danger notice plate, with and including erection, testing and commissioning, complete all as specified and directed including the following fixtures and fitments:- |
| 45 | (a) Aluminium bus bar four strips 500Amp, 415volts, fixed on epoxy insulated with panel fixed horizontally, duly insulated with heat shrinkable sleeves in colour code - 01 Set. (b) Incoming:- (i) MCCB 04 Pole, 300Amp, 25KA at 415volts, adjustable type with rotary handles -01 No(ii) CT's 250/5 -03 Nos with selector switch (iii) Ammeter Meter 0-250A digital type with selector switch -01 No. (iv) Voltmeter 0-500Volt with selector switch -01 No.(vi) Phase Indicating lamps -03No(vii) Control fuses / MCB -03 No. (c) Outgoing:-(i) MCCB 04 Pole, 160Amp, 25KA with rotary handles - 02Nos (ii) MCCB 04 Pole, 100Amp, 25KA - 03Nos & MCCB 04 Pole, 32Amp, 15KA - duly connected with contactor - 01Nos (iii) MCB TPN, 63Amp 10KA -05 Nos (iv) Timer & Protection MCB and Manual Auto control switch duly wind up to terminal block for connecting street light circuits. Please Enable Macros to View BoQ information |
| 46 | (a) Aluminium bus bar four strips 500Amp, 415volts, fixed on epoxy insulated with panel fixed horizontally, duly insulated with heat shrinkable sleeves in colour code - 01 Set. (b) Incoming:- (i) MCCB 04 Pole, 300Amp, 25KA at 415volts, adjustable type with rotary handles -01 No(ii) CT's 250/5 -03 Nos with selector switch (iii) Ammeter Meter 0-250A digital type with selector switch -01 No. (iv) Voltmeter 0-500Volt with selector switch -01 No.(vi) Phase Indicating lamps -03No(vii) Control fuses / MCB -03 No. (c) Outgoing:-(i) MCCB 04 Pole, 160Amp, 25KA with rotary handles - 02Nos (ii) MCCB 04 Pole, 100Amp, 25KA - 03Nos & MCCB 04 Pole, 32Amp, 15KA - duly connected with contactor - 01Nos (iii) MCB TPN, 63Amp 10KA -05 Nos (iv) Timer & Protection MCB and Manual Auto control switch duly wind up to terminal block for connecting street light circuits. Please Enable Macros to View BoQ information |