| Sl. No. | Item Description |
| 1 | Dismantling of plain or corrugated steel sheeting any gauge, thickness, including Nainital or similar pattern roof coverings, complete all as specified and directed by Engr-in-Charge. |
| 2 | S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to walls,fixed with self tapping screws complete all as specified and directed by Engr-in-Charge. |
| 3 | S&F Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to walls fixed with self tapping screws , complete all as specified and directed by Engr-in-Charge. |
| 4 | S&F 2mm thick fibre glass reinforced translucent plain sheeting with side lap fixed with with self tapping screw or L-type or J-type or cranked hook bolts as in roof, wall etccomplete all as specified and directed by Engr-in-Charge. |
| 5 | Dismantling wrought iron or mild steel work of escription not otherwise provided for complete all as specified and directed by Engr-in-Charge. |
| 6 | S&F Rolled Mild steel of grade Fe 410 -W (GdeE- 250) Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc complete all as specified and directed by Engr-in-Charge. |
| 7 | M&L prepation of new or previously untreated surfaces of steel and applying two coat of Synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed by Engr-in-Charge. |
| 8 | M&L for preparation of old surfaces of steel and applying one coat of Synthetic enamel paint complete all as specified and directed by Engr-in-Charge. |
| 9 | Demolition of stone slabs and tiles of any description or thickness in floors, aprons etc. laid, bedded and pointed in any mortar complete all as specified and directed by Engr in charge. |
| 10 | Demolition of PCC (un-reinforced) in ground floors & pavings n.exc 15 CM thickness below or above ground level complete all as specified and directed by Engr-in-Charge. |
| 11 | M&L for PCC Type B-1, 1:2:4 (using 20 mm graded granite stone aggregate) cast in situ as in copings, bed plates, kerbs and the like including weathering, slightly rounded or chamfered angles & throating and use of form work complete all as specified and directed by Engr-in-Charge. |
| 12 | Demolition of Cement Concrete (reinforced) in above ground floor and paving n.exc 15cm thickness (below or above ground level) complete all as specified and directed by Engr-in-Charge. |
| 13 | S&F PCC type B1 1:2:4 (20mm graded aggregate) Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed by Engr-in-Charge. |
| 14 | S&F for TMT bars of Mild steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips Complete all as specified and directed. |
| 15 | S&F for Formwork for fair finish of concrete to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick complete all as specified and directed by Engr-in-Charge. |
| 16 | Demolition of Brickwork or stone/boulders masonry built in cement mortar complete all as specified and as directed by the Engr-in-charge |
| 17 | M&L walling of random rubble masonary , uncoursed, well bonded, bedded and solidly hearted, bulit in cement mortar 1:6 complete all as specified and directed by Engr-in-Charge. |
| 18 | M&L except walling of random rubble masonary , uncoursed, well bonded, bedded and solidly hearted, bulit in cement mortar 1:6 complete all as specified and directed by Engr-in-Charge. |
| 19 | M&L for precast cement concrete type C1 1:3:6 (using 20mm graded aggregate) block masonry with soild block, exc 10cm width and setting in cement mortor 1:6 complete all as specified and as directed by Engr-in-Charge. |
| 20 | M&L rendering 15mm thick in CM 1:4 on fair faces of stone masonary surfaces, finishing even and smooth without using extra cement complete all as specified and directed by Engr-in-Charge. |
| 21 | M&L rendering 15mm thick in CM 1:4 on fair faces of brick work or concrete surfaces, finishing even and smooth without using extra cement complete all as specified and directed by Engr-in-Charge. |
| 22 | M&L for preparation of new plastered surfaces on walls and applying two coats of cement based paint over a coat of primer complete all as specified and directed by Engr-in-Charge. |
| 23 | M&L for 75mm thick PCC type D-2 1:4:8 (using 40mm graded stone aggregate) as in sub base flooring, surface finished even and rough to receive floor topping complete all as specified and directed by Engr-in-Charge. |
| 24 | M&L for 25mm thick plain cement concrete type B-0 (12.5mm graded stone aggregate) 1:2:4 as in floor complete all as specified and directed. |
| 25 | M&L Non Skid coloured ceramic tiles 7 to 8mm thick (square/ rectangular) area of each tiles exc 0.18 and n.exc 0.38 Sqm in floors over 15mm thick screed bed in cement mortar 1:6 etc set and jointed in neat cement slurry and pointed in white or coloured cement to match all as specified and as directed |
| 26 | M&L for Machine cut kota stone slab flooring 20-25mm thick over 20 mm thick screed bed in CM 1:4 laid over cement slurry, pointed and jointed with grey mixed with pigment to match the shade of the slab including cutting, rubbing and polishing complete all as specified and directed by Engr-in-Charge. |
| 27 | M&L for coloured granite work (table rubbed and polished) 20 mm thick as in steps,jambs, pillars, plateforms and like machine cut bedded and jointed & pointed with white cement and pigment to match the shade of granite stone incl grinding, polishing and moulding over 20mm thick screed bed or bedding layer in CM 1:4 complete all as specified and directed by Engr-in-Charge. |
| 28 | M&L for anti-skid endura matt finished 10mm thick of premium quality, area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles laid over & including 15 mm thick screed bed in CM 1:4 complete all as specified and directed by Engr-in-Charge. |
| 29 | Dismantling wall and ceiling boards (fibre, pulp, insulation, etc) or insulation boards/slabs/blankets, any thickness, including cover fillets complete all as specified and directed by Engr-in-Charge. |
| 30 | Dismantling timber scantling as in fillets, rails, posts, rafters, purlins etc under 40 Sqcm in section in framed work in any position complete all as specified and directed by Engr-in-Charge. |
| 31 | M&L for Plain fillets of second class soft wood (KAIL), sectional area exceeding 13 Sqcm but not exceeding 25 Sqcm in square, rectangular or traingular in section, clean sawn secured with nails or brads complete all as specified and directed by Engr-in-Charge. |
| 32 | M&L for Plain fillets of second class soft wood (KAIL), sectional area exceeding 6 Sqcm but not exceeding 13 Sqcm in square, rectangular or traingular in section, bullnosed, splayed, chamfered or rounded on one edge or face complete all as specified and directed by Engr-in-Charge. |
| 33 | M&L for Plain fillets of second class soft wood (KAIL), sectional area not exceeding 3 Sqcm in square, rectangular or traingular in section, bullnosed, splayed, chamfered or rounded on one edge or face complete all as specified and directed by Engr-in-Charge. |
| 34 | S&F 12mm thick prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination fixed with nails to timber frame work complete all as specified and directed by Engr-in-Charge. |
| 35 | S&F 9mm thick prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination fixed with nails to timber frame work complete all as specified and directed by Engr-in-Charge. |
| 36 | Taking down chowkats with shutter (without taking off shutter from the frame) exc 1.5 sqm but not 4 Sqm each complete all as specified and directed by Engr-in-Charge. |
| 37 | S&F in repair Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, incl taking down the old section/ frame complete as per architectural drawings and the directions of Engineer-in-Charge. |
| 38 | S&F Sheet glass,ordinary quality and glazing 4.8mm thickness with oil putty in square not exc 0.5 sq. m in each pane complete all as specified and directed by Engr-in-Charge. |
| 39 | S&F 9mm thick prelaminated particle board, interior grade, prelaminated both side with decorative choice lamination complete all as specified and directed by Engr-in-Charge. |
| 40 | S&F in repair Door closer hydraulically of aluminium (die cast) body regulated,designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80kg and fixed complete all as specified and directed by Engr-in-Charge. |
| 41 | S&F 200mm long Aluminium anodisedl barrel tower bolt of extruded section and fixed complete all as specified and directed by Engr-in-Charge. |
| 42 | S&F 125mm extruded aluminium alloy handles febricated type anodised complete all as specified and directed by Engr-in-Charge. |
| 43 | S&F 100mm mild steel butt hinges medium weight , cold rolled complete all as specified and directed by Engr-in-Charge. |
| 44 | S&F 300mm Aluminium alloy, anodised,sliding door bolts with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed complete all as specified and directed by Engr-in-Charge. |
| 45 | S&F in repairs Curtain rod of CP finish, made of heavy duty MS/ Stainless steel pipe of 25mm dia and 0.8mm to 1.00 mm thickness with high quality chrome plating for mirror finish and rust resistance incl brackets of matching CP wall brackets with proper projection, end caps (decorative finish), screws, rawl plugs fixed to wall with stainless steel screws and nylon plugs complete all as specified and directed by Engr-In-Charge. |
| 46 | Hacking out old broken glass panes (any thickness size quality or description ) from wooden frame fixed with oil putty or beads area not exc 0.5 Sqm each complete all as specified and directed by Engr-in-Charge. |
| 47 | S&F 4mm thick glass pan ordinary quality and glazing with oil putty in square not exc 0.5 sqm each pane complete all as specified and directed by Engr-in-Charge. |
| 48 | S&F in repair sink with drainage board made of stainless steel 1 mm thick with plugs, washers and wastes, including bedding in cement mortar to dwarf wall or including fixing cantilever brackets of angle iron and connecting union to pipe over all size 915x460mm and bowl size 410x330x160mm complete all as specified and directed by Engr-in-Charge. |
| 49 | Taking up or down steel water tubing of 20mm dia bore and connection incl cleaning for refixing or removal to stores complete all as specified and directed by Engr-in-Charge. |
| 50 | Taking up or down steel water tubing of 25mm dia bore and connection incl cleaning for refixing or removal to stores complete all as specified and directed by Engr-in-Charge. |
| 51 | M&L for 20mm 3-layer PP-R Polypropylene random copolymer) concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded Polypropylene random fittings fixed complete to walls, ceilings or in floors etc complete all as specified and directed by Engr-in-Charge. |
| 52 | M&L for 25mm 3-layer PP-R Polypropylene random copolymer) concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded Polypropylene random fittings fixed complete to walls, ceilings or in floors etc complete all as specified and directed by Engr-in-Charge. |
| 53 | S&F in repair 15mm Long body Cast copper alloy, Chromium Plated Bib tap fancy type with crutch or butterfly handle, screwed for iron pipe or for brass pipe of for ferrule and fixed complete all as specified and directed by Engr-in-Charge. |
| 54 | Dismantling water storage tanks of capacity exc 500 & n.exc 1000 ltrs and removing to store complete all as specified and directed by Engr-in-Charge. |
| 55 | S&F puf tank of capacity 1000 ltrs capacity complete all as specified and directed by Engr-in-Charge. |
| 56 | S&F in repair WHB counter sunk type ovel under/over counter shape in fixed & on stone slab incl necessary cutting if required etc complete all as specified and directed by Engr-in-Charge. |
| 57 | S&F, in repair, Grating doom, 150mm dia of cromium plated (minimum weight 150gms) complete all as specified and directed by Engr-in-Charge. |
| 58 | Taking down eaves gutter and rain water pipe any size any pattern , PVC/ AC pipe including all fittings ,heads shoes, bends etc including removal to store ,Internal dia of pipe in 75MM/110mm complete all as specified and directed by Engr-in-Charge. |
| 59 | S&F 75mm bore PVC (SWR) pipes, single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed by Engr-in-Charge. |
| 60 | S&F 75mm bore, PVC (SWR), bends any radius complete all as specified and directed by Engr-in-Charge. |
| 61 | S&F 75 mm dia PVC (SWR), floor trap with grating including jointing with solvent cement complete all as specified and directed by Engr-in-Charge. |
| 62 | S&F in repair 5mm thick looking mirror of size 600x450mm of selected quality glass mounted on 6mm thick AC building board or commercial plywood and aluminium angle beading around mirrior fixed on wall PVC plug and screws etc complete all as specified and directed by Engr-in-Charge. |
| 63 | S&F in repair 15mm Stop valve/angle cock, fancy type, chromium plated with long shunk and cup (concealed type) high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for union and fixed complete all as specified and directed by Engr-in-Charge. |
| 64 | S&F in repair 15mm bore Pillar taps cast copper ally, with capstain head, fancy type, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and flynuts, screwed for iron pipe and fixed complete all as specified and directed by Engr-in-Charge. |
| 65 | S&F in repair 450 mm long PVC connection 15mm bore with PTMT nuts complete all as specified and directed by Engr-in-Charge. |
| 66 | S&F Anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer-in-charge. |
| 67 | M&L preparation of old painted wooden /wood based materials surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats synthetic enamel complete all as specified and directed by Engr-in-Charge. |
| 68 | M&L for 75mm thick, plain cement concrete, type C-2 1:3:6 (using 40mm graded stone aggregate) as in plinth protection work and similar, surface finished even and floor topping complete all as specified and directed by Engr-in-Charge. |
| 69 | M&L for machine pressed precast concrete interlocking paver block any shape and size conforming to IS 15658-2006 of 60 mm thickness, M-35 Grade with grey cement and pigment over 25mm thick sand cushion complete all as specified and directed . (Note- Sand cushion measured and paid seperately) |
| 70 | M&L for Sand filling under floors or in foundation including watering and consolidation complete all as specified and directed by Engr-in-Charge. |
| 71 | M&L for plain cement concrete Type B-1, 1:2:4 (using 20 mm graded granite stone aggregate) cast in situ as in copings, bed plates, kerbs and the like including weathering, slightly rounded or chamfered angles & throating and use of form work complete all as specified and directed by Engr-in-Charge. |
| 72 | Taking down chowkats with shutter (without taking off shutter from the frame) not exc 1.5 Sqm each complete all as specified and directed by Engr-in-Charge. |
| 73 | S&F plain solid straight chowkats and framed wrought framed rebated on the solid rounded or chamfered put together with glue pinned at joints in 2nd class soft wood KAIL) complete all as specified and directed by Engr-in-Charge. |
| 74 | S&F 35mm thick 2nd class soft wood (KAIL) plain framed panelled shutter (any number of panels) with panels of timber flat on both sides (Feather edge) or of veneered particle board medium density wood particle board with commercial face veneers and fitted to chowkhat complete all as specified and directed by Engr-in-Charge. |
| 75 | S&F 30mm thick 2nd class soft wood (KAIL) glazed and skeleton shutter open rebated and prepared to receive glass, gauge etc divided into squares with plain chamfered or rounded, mitred and rebated sash bars any numbers complete all as specified and directed by Engr-in-Charge. |
| 76 | M&L for factory made Glazed and skelton shutters 35mm thick of 2nd class hard wood rail & style open rebated and prepared to receive glass or wire gauze etc. shutters (without shash bars), size of members of shutters as specified in SSR Part-1, secton 8, clause 8.24(a) kiln seasoned and pressure treated complete all as specified and directed by Engr-in-Charge. |
| 77 | S&F Galvanised mild steel wire cloth 0.56mm nominal dia of wire and average width of aperture 1.18mm fixed with tinned tacks or galvanized wire staples complete all as specified and directed by Engr-in-Charge. |
| 78 | S&F Mild steel 300mm ordinary rat tail rod pattern spring including roller plate complete all as specified and directed by Engr-in-Charge. |
| 79 | S&F 75mm mild steel butt hinges medium weight, cold rolled complete all as specified and directed by Engr-in-Charge. |
| 80 | S&F 150mm long Aluminium anodisedl barrel tower bolt of extruded section and fixed complete all as specified and directed by Engr-in-Charge. |
| 81 | S&F 100mm extruded aluminium alloy handles febricated type anodised complete all as specified and directed by Engr-in-Charge. |
| 82 | M&L for preparation of new wood and wood based material surface of any description, not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed by Engr-in-Charge. |
| 83 | Dismantling timber scantlings 40 sq. cm and over in section, in any position section in framed work, in any position complete all as specified and directed by Engr-in-Charge. |
| 84 | Taking down cement plaster on Brick or concrete surfaces incl racking out joints hacking for key scrubbing down with water etc complete all as specified and directed by Engr-in-Charge. |
| 85 | M&L rendering 15 mm thick in CM 1:6 on fair faces of stone masonary surfaces, finishing even and smooth without using extra cement complete all as specified and directed by Engr-in-Charge. |
| 86 | M&L for preparation of new plastered surfaces on walls and applying two coats of distemper oil emulsion over a coat of primer complete all as specified and directed by Engr-in-Charge. |
| 87 | M&L for Non-skid coloured ceramic tiles, 7 to 8mm thick, area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles laid over & including 15 mm thick screed bed in CM 1:6 complete all as specified and directed by Engr-in-Charge. |
| 88 | M&L for Glazed coloured ceramic tiles of size 300x450x7/ 450x350x7mm thick in vertical surface set and jointed in neat cement slurry and pointed in white cement with pigment to match the shade of tiles laid over and including 10 mm thick rendering in CM (1:6) complete all as specified and directed by Engr-in-Charge. |
| 89 | M&L for chequered cement concrete tiles 300x300x25mm thick with grey cement and no pigment and set jointed and pointed in neat cement slurry as in floor over 20 mm thick sreed bed or bedding layer in CM 1:4 complete all as specified and directed by Engr-in-Charge. |
| 90 | S&F cement concrete type B1 1:2:4 (20mm graded aggregate ) Beams, cantilevers, bressumm ers, lintels over 1.5m span complete all as specified and directed by Engr-in-Charge. |
| 91 | S&F for TMT bars of Mild steel bars 6mm dia to 8mm dia , cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips Complete all as specified and directed. |
| 92 | S&F for Formwork for fair finish of concrete to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs,etc. also splays between floors and beams, etc complete all as specified and directed by Engr-in-Charge. |
| 93 | S&F 110mm bore PVC (SWR) pipes, single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed by Engr-in-Charge. |
| 94 | S&F 110mm bore, PVC (SWR), bends any radius complete all as specified and directed by Engr-in-Charge. |
| 95 | S&F in repair Vitreous china squatting pan, Orissa Pattern size 580mm x 440 white incl connection to floors/S/P trap with integral foot rest but excluding flushing cistern and flush pipe including placing in position complete all as specified and directed by Engr-in-Charge. |
| 96 | S&F in repairs 32 mm dia of flush pipe for low level cistern as in repair complete all as specified and directed by Engr-in-Charge. |
| 97 | S&F in repair 10 ltr PVC valveless,syphonic action type , flushing cistern , low level,white , with inlet , ball valve , float and handle incl brackets complete all as specified and directed by Engr-in-Charge. |
| 98 | S&F in repair 15mm Cast copper alloy, Chromium Plated Bib tap fancy type with crutch or butterfly handle, screwed for iron pipe or for brass pipe of for ferrule and fixed complete all as specified and directed by Engr-in-Charge. |
| 99 | Dismantling water storage tanks of capacity exc 250 & n.exc 500 ltrs and removing to store complete all as specified and directed by Engr-in-Charge. |
| 100 | S&F puf tank of capacity 500 ltrs capacity complete all as specified and directed by Engr-in-Charge. |
| 101 | Surface excn not exc 30cm in deep and averagig 15cm in deep and getting out in hard/dence soil complete all as specified and directed by Engr-in-Charge. |
| 102 | Hard core of broken stones or boulders of gauge in exc 63mm deposited spread and levelled in layers nexc 15cm thick incl watering and rolled to true surface complete all as specified and directed by Engr-in-Charge. |
| 103 | M&L 75mm thick cement concrete (1:3:6) type C2 using 40mm graded aggregate as in sub base to floor complete all as specified and directed by Engr-in-Charge. |
| 104 | M&L for providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the reqd line, level and curvature,jointed and pointed with cement mortar 1:3 including making joints with or without grooves, including making drainage opening where ever reqd complete all as specified and direction of Engr in charge |
| 105 | Excavating in post holes (or similar holes) each n exc 0.5 Cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm in Hard/ dense soil complete all as specified and directed by Engr-in-Charge. |
| 106 | M&L for PCC 1:3:6 type C2 using 40 mm graded stone agg as in foundation, filling and mass concrete complete all as specified and directed by Engr-in-Charge. |
| 107 | Removing excavated material not exc 50m and depositing where directed at a level n. exc. 1.50m above the starting point etc complete all as specified and directed. |
| 108 | S&F Fe-290 (Gde E-165) Framed work as in ornamental door or gates of angle or other section with gusset plates rails, braces etc, complete, drilled for fixing of steel sheeting or other covering. Doors, etc to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fiting (exclusive of steel sheeting or other covering, running rails and guides) and hanging, also fastening and fixing complete all as specified and directed by Engr-in-Charge. |
| 109 | S&F Rolled mild steel Gde Fe-290 (Gde E-165) as in Plates (plain or chequered) channels,angle sections, square cut or notched (ordinary & counter sunk) forming holes, with riveted, bolted or welded attachment complete all as specified. |
| 110 | S&F in repair high pressure laminate sheet 6.00 mm thickness for external purpose fixing on frame by using connector and fastener complete all as specified and directed by Engr-in-Charge. (Any colour as approved by GE) |
| 111 | S&F Stainless steel 304grade English letter box type, fabricated by using 1mm thick SS sheet with acrylic cladding (4.0mm thick) for transmission of light and illumination at back with LED with warm white colour, size n exc 300mm including fittings arragement by using cleat, connector and fastener etc complete all as specified and directed by Engr-in-Charge. |
| 112 | S&F Acrylic sheet (4.0mm thick) 08 MTN DIV LOGO hollow type (size nexc 400 mm) front base using 1mm thickness and the rib channel work with LED light fittings in required colour complete all as specified etc using complete all as specified. |
| 113 | S&F precast RCC (1:2:4) using 20mm graded agg boundry pillars of Ht 1800 mm & size 150x150 mm with vertical steel of 10mm dia 04 Nos & stirrups 08mm dia at distance of 150 mm c/c and base pillar of size 450x150mm thickness with 4 nos 10mm dia rod both ways including formwork complete all as specified and directed by Engr-in-Charge. |
| 114 | Taking down carefully copper or aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches ceiling roses, pendants, sockets bulk, head fitting, tube light fitting by unscrewing carefully from boards etc and making good, distrubed surface of walls floors etc. |
| 115 | M&L for Point wiring for light/fan/bell with FRLS cable of 1.5sqmm PVC insulated (red/blue/yellow for phase, black for neutral and green for earth) unsheathed multistranded copper conductor 1100 volts grade in and including not less than 2mm thick PVC casing caping with all accessories and 1.5sqmm green in colour PVC insulated multistranded copper conductor FRLS cable for earth continuity connected to common earth dolly incl MS/GI sunken box with 3mm thick pre laminated hylum sheet/PVC box with back plate,flush/surface type for mounting fittings such as switches,socket,and regulator complete all as specified and directed for one light point or bell/buzzer point controlled by one switch. |
| 116 | All as per Srl item No 115 here in before but using cable size 2.5 Sqmm for one 3 pin socket outlet 5 Amps independent board. |
| 117 | All as per Srl item No 115 here in before but using cable size 2.5 Sqmm for one 3 pin socket outlet 15 Amps independent board. |
| 118 | S&F in replacement of Switch piano flush type 5 Amps, single pole one way complete all as specified and directed by engr-in-charge. |
| 119 | S&F in replacement of Switch socket combination 2 in 1, and 3 and 2 pin, 5 Amps flush type complete all as specified and directed by engr-in-charge. |
| 120 | S&F in replacement of Switch socket combination 2 in 1,3 pin, 5 and 15 Amps flush type complete all as specified and directed by engr-in-charge. |
| 121 | S&F in replacement of in Ceiling rose on PVC Square Block surface bakelite 65x50mm, two to three terminals complete all as specified and directed by engr-in-charge. |
| 122 | S&F in replcement of LED white colour 1x18 Watt, 220 V, AC, Decorative ultra slim square profile LED lighting fixture with extruded polycarbonate, environmental friendly, energy efficient ready to use, connecting up with two/three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. |
| 123 | S&F in replacement of Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings complete all as specified and directed by engr-in-charge. |
| 124 | S&F in replacement of LED bulb 09 watt, 230 volts complete all as specified and directed by engr-in-charge. |
| 125 | S&F in replacement Sheet metal enclosure for DB's Double door, single pole and neutral, 240V, 08 way with 200 Amp rated bus bar including blanking plates where required. Complete all as specified and directed. |
| 126 | S&F in replacement Sheet metal enclosure for DB's Double door, single pole and neutral, 240V, 12 way with 200 Amp rated bus bar including blanking plates where required. Complete all as specified and directed. |
| 127 | S&F in replacement 240 V 10 KA C curve miniature circuit breaker (MCB) SPN 40 to 63 Amp in the MCB DB complete with connection testing and commissioning complete all as specified and directed by engr-in-charge. |
| 128 | S&F in replacement 240 V 10 KA C curve miniature circuit breaker (MCB) SP 5 to 32 Amp in the MCB DB complete with connection testing and commissioning complete all as specified and directed by engr-in-charge. |
| 129 | S&F in replacement LED light fitting 1x9W/1x10W bulkhead luminaries including LED light driver holder connecting up three core flexible copper conductor cable of suitable size complete all as specified and directed by engr-in-charge. |
| 130 | S&F in replacement of LED Flood light fitting 70 watt 5000 k green/natural white , IP>66 ,grey powder coated die cast aluminium housing , inbuilt energy efficent surge protected electronic driver, with all connected accessories all as specified and directed . |
| 131 | M&L in replcement of submain wiring comprising single core, 2 Runs of 6.0 sqmm nominal cross sectional area multi stranded FRLS copper conductor cable, PVC insulated unsheathed 1100 Volts grade drawing in and including min 25mm dia. PVC conduit/ PVC Casing Caping ISI Marked(heavy duty) and its fittings on surface/recessed complete including provision of 1X6.0 sqmm nominal cross sectional area multi stranded FRLS copper conductor cable, PVC insulated unsheathed 1100 Volts grade as earth wire and using color code as per IS complete all as specified and directed by Engr-In-charge.(Note :- Extra length of cables/ wire required for connection to MCBs shall not be measured and the rate quoted by contractor for per unit shall be deemed accordingly) |
| 132 | S&F in replacement exhaust fan made of sturdy engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, copper winding of sweep 300mm including cutting of hole into wall of suitable size including fixing of plyboard and making the surface good complete all as specified and directed by engr-in-charge. |
| 133 | S&F in replacement exhaust fan, steel body, AC single phase, 230 V of size 380 mm sweep with blades and frame and louvers including cutting of hole into wall of suitable size including fixing of plyboard and making the surface good complete all as specified and directed by engr-in-charge. |
| 134 | S&F in replcement of 1100 volts grade heavy duty 16 sqmm 2 core flat cable PVC insulated aluminium stranded conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended complete all as specified and directed by engr-in-charge. |
| 135 | Dismantling and M&L for Earthing complete with galvanised steel earth plate electrode of size 60cm×60cm× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to and including GI iron wire of size 4 mm dia by means of GI bolts, nuts, check nuts and washers, protected by 15mm bore GI light grade ISI marked pipe upto and including test points. Earth plate shall be surrounded by alternate layer 15cm thick of charcoal or coke and common salt all around bottom and top , 20cm bore GI medium grade ISI marked pipe for watering and including funnel,wire mesh,PCC chamber pit made with PCC(1:3:6) type C-1(using 20mm graded stone aggregate) including necessary form work, excavation and earth work in any type of soil, returning filling and disposal of surplus soil to a distance not exceeding 50M, CI pit cover duly painted with two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified & shown in electrical plate No.3 of SSR 2009(Part-I) and all as directed.Note:- (i) Protection pipe and earthing strip upto test point from top of the earth plate and further upto the body of electrical equipment shall be included in the unit rate of this item.(ii) Earth testing arrangement should be done by contractor as per direction of Engr-In-Charge. |
| 136 | S&F in replacement exhaust fan made of sturdy Engineering plastic complete, AC single phase, 230 V of size 250 mm sweep with blades and frame and louvers complete with cutting of suitable size of hole on wall with all connected accessories and making surface good after fixing complete all as specified and directed by engr-in-charge. |
| 137 | M&L for sub main wiring for wall washer lights etc of PVC insulated and PVC Round Sheathed 3-core Copper Conductor (flexible) industrial cable for Voltage Grade 1100 Volt, 1.5 sqmm in and including rigid PVC conduit of size 25 mm ISI mark and its accessories with fixing arrangements on pole, surface, wall, ceiling and trenches at a depth and width of min 150mm etc complete all as specified and directed. Note : One run of 3-core Copper Conductor (flexible) industrial cable ,one run of PVC conduit together taken as one length for measuring unit length. |
| 138 | S&F outdoor type LED wall washer light, 10 watt, 3000 k , 2way (Bi directional light beam), warm white , Suitable for Surface mounted, IP>65 ,Black powder coated aluminium fixture, with suitable size of connected accessories to fix complete all as specified and directed.Make:- Philips Cat part no. SKU:919215851094 or equivalent. |
| 139 | S&F Sheet metal enclosure for DB's Double door, single pole and neutral, 240V, 4 way with 200 Amp rated bus bar including blanking plates where required complete all as specified and directed. |
| 140 | S&F 240 V 10 KA C curve MCB SPN 32Amp in the MCB DB complete with connection testing and commissioning complete all as specified and directed by Engr-in-Charge. |
| 141 | S&F 1100 volts grade heavy duty 10 sqmm 2 core flat cable PVC insulated aluminium stranded conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections complete all as specified and directed by Engr-in-Charge. |
| 142 | S&F GI tubing Medium grade 50 mm bore for laid under trenches complete all as specified and directed by Engr-in-Charge. |
| 143 | Note : Deduction for amount of Rs. 78,450.00 as listed in Schedule 'A' Part-II (Schedule of Credit) shall be made while awarding of contract. Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail