| 1 | Taking down carefully existig copper/ alumn point wiring for light/ fan/ bell/ socket 5/15 Amp points complete with fitting and fixtures such as Switches, Sockets, Ceiling Rose, Lamp Holder and bracket fittings with Battens/ Conduits/ Wires and making good the disturbed surfaces of walls and roofs etc to match with existing surface complete all as specified and directed. |
| 2 | Taking down carefully unserviceable main switches and distribution boards (single phase or three phase) of any capacity with Isolators/ MCBs/ MCCBs, complete all as specified and directed. |
| 3 | Taking down carefully old unserviceable sub main wiring and making good disturbed surfaces and matching with existing complete all as directed and specified |
| 4 | M&L Point wiring complete with 1100 volts grade PVC FRLS insulated unsheathed cable of copper conductor, multi stranded of size 1.5 Sqmm, single core, drawn through & including new PVC rigid concealed conduit, medium grade of suitable size (not less than 20mm dia) duly ISI marked with all accessories such as bends, reducers, spacers, saddles, junction boxes, bakelite sheets and various sizes hylam sheets for mounting switch/ sockets, fan regulators etc complete with and including continuous earth wire of size 1.5 Sqmm, single core, PVC FRLS copper conductor, insulated, unsheathed, stranded (Green colour) connected to common earth dolly complete all as specified and directed for following :- (a) One light/ fan/ bell/ Bldg security light point controlled by one single pole one way switch. |
| 5 | All as per item No. 04 as above but one 3 pin, 5 Amp, socket outlet on the independet board controlled by one single pole one way switch board, complete all as specified and directed. |
| 6 | All as per item No. 04 as above but one 3 pin, 5 Amp, socket outlet on the same board controlled by one single pole one way switch board, complete all as specified and directed. |
| 7 | All as per item No. 04 as above here-in-before but wiring with 2.5 sqmm copper cable and 2.5 Sqmm copper cable as continuous earth wire for one 6 pin 6/16 Amps socket out let on independent board, complete all as specified and directed. |
| 8 | All as per item No. 07 as above here-in-before but wiring with 4 sqmm copper cable and 4 Sqmm copper cable as continuous earth wire for one 6 pin 6/16 Amps socket out let on independent board complete all as specified and directed. |
| 9 | All as per item No 04 above but existing conduit and existing Ms pressed steel/ cast iron box complete all as speicifed and directed.(a) One light point/fan/bell point controlled by one single pole one way switch. |
| 10 | All as per item No - 05 above but existing conduit and existing Ms pressed steel/ cast iron box complete all as specifed and directed. |
| 11 | All as per item No - 07 above but existing conduit and existing Ms pressed steel/ cast iron box complete all as specifed and directed. |
| 12 | M&L Point wiring complete with 1100 volts grade PVC FRLS insulated unsheathed cable of copper conductor, multi stranded of size 1.5 Sqmm, single core, drawn through & including new PVC casing caping condiuting of suitable size duly ISI marked with all accessories such as bends, reducers, spacers, saddles, junction boxes, bakelite sheets and various sizes hylam sheets for mounting switch/ sockets, fan regulators etc complete with and including continuous earth wire of size 1.5 Sqmm, single core, PVC FRLS copper conductor, insulated, unsheathed, stranded (Green colour) connected to common earth dolly, complete all as specified and directed for following :-(a) One light/ fan/ bell/ Bldg security light point controlled by one single pole one way switch. |
| 13 | All as per item No. 12 as above but one 3 pin, 5 Amp, socket outlet on the independet board controlled by one single pole one way switch board complete all as specified and directed. |
| 14 | All as per item No. 12 as above but one 3 pin, 5 Amp, socket outlet on the same board controlled by one single pole one way switch board complete all as specified and directed. |
| 15 | All as per item No. 12 as above here-in-before but wiring with 2.5 sqmm copper cable and 2.5 Sqmm copper cable as continuous earth wire for one 6 pin 6/16 Amps socket out let on independent board complete all as specified and directed. |
| 16 | S&F switch piano flush type, 5 Amp, single pole, one way, 240 volts complete all as specified and directed. |
| 17 | S&F in repair of switch piano flush type, 5 Amp, single pole, one way, 240 volts complete all as specified and directed. |
| 18 | S&F Bell push switch piano flush type, 5 Amp, single pole, one way, 240 volts complete all as specified and directed. |
| 19 | S&F Switch piano flush type, 15 Amp, single pole, one way, 240 volts complete all as specified and directed. |
| 20 | S&F in repair of Switch piano flush type, 15 Amp, single pole, one way, 240 volts complete all as specified and directed. |
| 21 | S&F socket outlet flush type, multipupose, 3 pin 5 Amp complete all as specified and directed. |
| 22 | S&F in repair of socket outlet flush type, multipupose, 3 pin 5 Amp complete all as specified and directed. |
| 23 | S&F socket outlet flush type, multipurpose 2 in 1,3 pin 5 & 15 Amp, 240 volts complete all as specified and directed. |
| 24 | S&F in repair of socket outlet flush type, multipurpose 2 in 1,3 pin 5 & 15 Amp, 240 volts complete all as specified and directed. |
| 25 | S&F ceiling rose surface bakelite 3 terminals 65 x 50mm complete all as specified and directed. |
| 26 | S&F batten holder insulated body suitable for LED lamp 220/240 volts, 6500K, B-22 base cap complete all as specified and directed. |
| 27 | S&F electronic ceiling fan regulator stepped type heavy duty 120W, 250 volts flush type and also compatible to BLDC fan complete all as specified and directed. |
| 28 | S & F in repair Modular Switch one way 6 A, 1 module complete all as per specified and directed. Make - Precision/Anchor/Havells/Legrand/Indoasian. |
| 29 | S&F in repair of Modular Bell push 6 Amps, one module, 240 volts complete all as specified and directed. |
| 30 | S & F in repair Modular Switch one way 16 A, 1 module complete all as per specified and directed.Make - Precision/Anchor/Havells/Legrand |
| 31 | S & F in repair Modular Socket, 6A - 2/3 pin combined 2 module complete all as per specified and directed.Make - Precision/Anchor/Havells/Legrand/ Indoasian. |
| 32 | S & F in repair Modular Socket, 6A/16A - 2/3 pin combined 2 module complete all asper specified and directed.Make - Precision/Anchor/Havells/Legrand/Indoasian. |
| 33 | S&F Modular ceiling fan regulator electronic stepped type heavy duty 120W, 250 volts flush type and also compatible to BLDC fan complete all as specified and directed.Make - Precision/Anchor/Havells/Legrand/Indoasian. |
| 34 | S & F in repair Modular white cover plate including GI box inner, 4 modulecomplete all as per specified & directed.Make : Precision/Anchor/Havells/Legrand/indoasian. |
| 35 | S & F in repair Modular white cover plate including GI box inner, 6 modulecomplete all as per specified & directed.Make : Precision/Anchor/Havells/Legrand/Indoasian. |
| 36 | S & F in repair Modular white cover plate including GI box inner, 8 module complete all as per specified &directed.Make : Precision/Anchor/Havells/Legrand/Indoasian. |
| 37 | S&F 20W, 6500K, 4 feet LED tube light fitting, energy efficient, 240 volts, fixed on wall/ ceiling etc including connecting up with twin core twisted flexible copper conductor cable with suitable size all as specified and directed. |
| 38 | Supply & Fix in repair 20W, 6500K, 4 feet LED tube light fitting, energy efficient, 240 volts, fixed on wall/ ceiling etc including connecting up with twin core twisted flexible copper conductor cable with suitable size all as specified and directed. |
| 39 | Fixing only in repair 20W, 6500K, 4 feet LED tube light fitting, energy efficient, 240 volts, fixed on wall/ ceiling etc including connecting up with twin core twisted flexible copper conductor cable with suitable size all as specified and directed. |
| 40 | S&F LED bulb of 9 watt, B22 base, 6500K all as specified and directed. |
| 41 | Supply & Fix in repair LED bulb of 9 watt, B22 base, 6500K all as specified and directed. |
| 42 | S&F Door Bell Ding Dong single phase 240 volts, white in colour, duly ISI marked complete all as specified and directed. |
| 43 | Supply and fixing in repair LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with highefficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size, complete all as specified and directed. |
| 44 | S&F LED sleeky bldg security light (Lens) fitting of 35 watts, 6000K, including GI bracket bend to shape made out of GI pipe light grade of 25 mm etc complete with two nos of bolts of suitable size, duly painted with two coats of synthetic enameled paint and all fixing arrangements to wall/ pole, including connecting up with 2 core copper flexible wire of size 23/00.0076 all as specified and directed. Make:- Havells, crompton and Bajaj. |
| 45 | S&F Factory made sheet metal enclosures double door type made out of CRCA 1.2 mm thick M.S. sheet, powder coated, partly embedded in wall, IP-43 protection, VTPN DB with 200 Amps rated bus bar, 4 way, 415 volts, vertical type, dust and vermin proof, suitable for incorporation of MCCBs/ MCBs, factory made, including thermal based release adjustable type 4 pole 63 Amps, 50 Hz, 415 Volts with rupturing capacity 16 KA and making good distrubbed surfaces with matching colour, complete all as specified and directed. |
| 46 | S&F Factory made sheet metal enclosures double door type made out of CRCA 1.2 mm thick M.S sheet, powder coated, SPN DB with 200 Amps rated bus bar, 8 way, IP-43 protection surface mounting, 240 volts, dust and vermin proof, suitable for incorporation of MCBs duly partially immersed in wall, factory made, including making good distrubbed surfaces with matching colour, complete all as specified and directed. |
| 47 | S&F Factory made sheet metal enclosures double door type made out of CRCA 1.2 mm thick M.S sheet, powder coated, SPN DB without bus bar, 2 way, IP-43 protection surface mounting, 240 volts, dust and vermin proof, suitable for incorporation of MCBs duly partially immersed in wall, factory made, including making good distrubbed surfaces with matching colour, complete all as specified and directed. |
| 48 | S&F MCCB thermal based release adjustable type 4 pole 100 Amps 50 Hz 415 Volts with rupturing capacity 16 KA including testing, complete all as specified and as directed. Make:- C&S Electric, Schenider, Siemens. |
| 49 | S&F MCB SPN, 40A-60A, 240 volts, \\"C\\" series, 10KA duly ISI marked, complete all as specified and directed. |
| 50 | S&F in Repair of MCB SPN, 40A-60A, 240 volts, \\"C\\" series, 10KA duly ISI marked, complete all as specified and directed. |
| 51 | S&F MCB SP, 6A-32 Amps, 240 volts, \\"B\\" series, 10KA duly ISI marked, complete all as specified and directed. |
| 52 | S&F in Repair of MCB SP, 6A-32 Amps, 240 volts, \\"B\\" series, 10KA duly ISI marked, complete all as specified and directed. |
| 53 | S&F Sub main wiring with two single core 2x6 sqmm FRLS PVC insulated and unsheathed stranded copper conductor alongwith earth wire 6 sqmm drawn in 25 sqmm PVC rigid conduit connected to main board complete all as specified and directed. (Two number cable and one number earth wire shall measured together as unit length). |
| 54 | S&F Sub main wiring with two single core 2x4 sqmm FRLS PVC insulated and unsheathed stranded copper conductor alongwith earth wire 4.0 sqmm drawn in 25 sqmm PVC rigid conduit connected to main board complete all as specified and directed. (Two number cable and one number earth wire shall measured together as unit length). |
| 55 | Supply & fixing in repair 1.5 Sqmm (Nominal area) FRLS PVC insulated and unsheathed single core cable 1100 Volts grade with stranded copper conductor complete all as per specified & directed. |
| 56 | Supply & fixing in repair 2.5 Sqmm (Nominal area) FRLS PVC insulated and unsheathed single core cable 1100 Volts grade with stranded copper conductor complete all as per specified & directed. |
| 57 | Suplying and fixing in repair 1100 volts grade heavy duty 16 Sq mm two core cable PVC insulated aluminium Stranded conductor, served with inner shething of PVC sheathed in service conections suspended by insulating hangers and procelean beat not more than I metre apart including 4Sq mm suspension wire, one twin core cable flat or circular, complete all as specified and directed. |
| 58 | Earthing complete with galvanized steel plate elecrode of size 60 cm x 60cm x 6.3 mm thick burried directly in ground vertically to a depth not less than 2.5 mtr below the ground level with top edge of earth plate at a depth not less than 1.5 mtr below ground level. Earth plate surrounded by 15mm thick packed alternative layers of charcoal dust and comman salt, earth lead GI wire of 4mm dia (8 SWG) by means of bolts , nuts, check nuts and washers of galvanised iron with thimbles. The other end of GI earth wire is connected to main switch board and protected by light grade GI pipe of 15 mm bore. provision of 20mm bore light grade GI pipe for watering including GI funnel and wire mesh. Pipe shallbe provided vertically upto top level of earth pit and then taken horrizontally to the earth pit. Cement concrete chamber of PCC ( 1:3:6 ) type C-2using 40 mm graded stone aggregate.The chamber shall be constructed one metre away from edge of earth pit. 50 mm thick pre cast cover of cement conrete (1:2:4) type B-1 using 20 mm graded stone aggregate and MS angle iron 50 x 50 x 6 mm frame including two coats of painting over a red oxide to exposed steel surfaces. excavation in soft / loose soil, returning filling and removal of surplus soil to a distance of 50 mm as directed and shown in Electrical Plate No- 3 of SSR Part-1 (2009). |
| 59 | Supply and fixing in repair of rigid non-metallic PVC conduit of dia 20 mm exclusive of boxes (junction/ terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc, complete all as specified and directed. |
| 60 | Supply & fixing in repair Capacitor (ISI Marked) 2.5 mfd complete all as specified and directed by Engr-in-Charge. |
| 61 | S&F in Repair of MCB TPN, 40A-100A, 240 volts, \\"C\\" series, 10KA duly ISI marked, complete all as specified and directed. |
| 62 | Note: The work is of maintenance nature, minor repair shall be carried out and paid in relevant items irrespect of complete rewiring as directed Please Enable Macros to View BoQ information |