Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Stage Contract for Maintenance of 33/11 KV Receiving Stations in respect of STD Ganderbal Sub Division Ganderbal only |
| 2 | Supply, Fabrication, testing and Commissioning of PVC insulated Copper Bus Bar including nuts and Bolts.(The job includes necessary modification fabrication of Busbar as per requirement & alignment to existing Panels). |
| 3 | Supply installation Testing & Commissioning of 11 KV Vacuum Interrupters (800A/600A as per already installed) for below make.The job includes dismantling of damaged interrupter. |
| 4 | Vijai, Easun Reyrolle, Alind, Alind, Electric Field, Pasca, Crompton, ABB, and out door type 11kv Breakers. |
| 5 | Sudhir, Schneider |
| 6 | Installation/Fixing, Testing & Commissioning of 11 KV Vacuum Interrupters of above makes including dismantling of damaged interrupter. |
| 7 | Supply installation Testing & Commissioning of 11 KV vacuum Interrupters Housing of below mentioned make. |
| 8 | Vijai and Easun Reyrolle (Per Phase) |
| 9 | Alind (Assembly upper set/ Lower set). |
| 10 | ABB/Electric Field/Crompton/S&S ( per Phase) |
| 11 | Sudhir and Schneider (Per phase) |
| 12 | Outdoor type PCVCB upper and lower part(Per phase) |
| 13 | Installation, testing and commissioning of 11KV vacuum Interrupters Housing of above mentioned make including dismantling of damaged assembly. |
| 14 | Supply Installation, testing and commissioning of of 11 KV CTs indoor type cast resin of following make and ratios including dismantling of damaged CT's and transportaion of Red material back to Divisonal store. |
| 15 | 750-375/5-5-5A Metering, Protection and Differential Core |
| 16 | 800-400/5-5-5 A Metering, Protection and Differential Core |
| 17 | 600-300/5-5-5 A Metering, Protection and Differential Core |
| 18 | 600-300/5-5 A Metering and Protection Core. |
| 19 | 400-200/5-5 A Metering & Protection Core |
| 20 | 300-150/5-5 A Mertering & Protection Core |
| 21 | 100-50/5-5 A Metering & Protection Core |
| 22 | 40-20/5-5A Metering & Protection Core |
| 23 | Installation, testing and commissioning of 11 KV CTs indoor type cast resin of above makes & Ratios including dismantling of damaged CT's and Transportation of new set from divisional store to site including transportaion of Red material upto Divisonal store. (The job includes identification of damaged part so that exact part can be arranged from OEM) |
| 24 | Supply, Installation, Testing and commissioning of Energy meter of Secure make with latest series premier 5000 of 11kv level and 33kv level with 5A secondary. 11kv/110v-5A / 33kv/110v-5A |
| 25 | SITC of G.I channel iron, angle iron, flat iron etc including necessary fabrication as per requirement including paint job. |
| 26 | Supply, Installation, testing and commissioning of 11 KV CT's outdoor type Dead tank type including dismantling of damaged CT's. (CT set to be provided should be of OEM as per already installed CT set) (The job includes identification of damaged part so that exact part can be arranged from OEM) including transportaion of Red material upto Divisonal store. |
| 27 | 600-300/5-5-5 A Metering, Protection and Differential Core |
| 28 | 400-200/5-5A Metering, Protection and Differential Core |
| 29 | 400-200/5-5A Metering & Protection Core |
| 30 | SITC of 11 KV PT set indoor type (11KV/110V) ER, Electric Field, Alind etc. |
| 31 | SITC of 11 KV PT indoor type (11KV/110V) of Schneider, CG etc. |
| 32 | SITC of 11 KV outdoor Dead tank type PT's ( 11KV/110 V). |
| 33 | Installation, testing and commissioning of 11 KV PT's (11 KV/110 V) indoor type and outdoor type including Transportation of new one from divisional store or otherwise to site including dismantling of existing PTs & transportation of Red Material upto Divisional Store |
| 34 | Supply Installation, testing and commissioning of 33 kV Current Transformer with Metering and Protection core, P S Class (36kV, 70kV (rms), 170kVp, 25 KA for 3 sec, Accuracy 0.5, Burden 30 VA, 1Φ, Outdoor) (1 No per Φ) of following ratios. |
| 35 | 400-200/5-5-5 A (Metering, Protection and Differential Core ) |
| 36 | 250-125/5-5-5 A (Metering, Protection and Differential Core ) |
| 37 | 300-150/5-5-5 A (Metering, Protection and Differential Core ) |
| 38 | Installation, testing and Commissioning of 33 kV Current Transformer including Transportation of new one from divisional store or otherwise and Transportation of Red item back to Divisional store. |
| 39 | Supply Installation, testing and commissioning of 33 kV PT's (33 kV /110 V single Phase outdoor type Potential Transformers |
| 40 | Installation, testing and Commissioning of various 33 KV PT's |
| 41 | Supply Installation, Testing and Commissioning of 11 KV VCB Panel including Transportation and supply of all accessories, clamps & Stand for commissioning of panel in (along with GTP and Test Certificate) |
| 42 | Installation, Testing and Commissioning of 11 KV VCB Panel and supply of all accessories, clamps & Stand for commissioning of panel. including Transportation from divisional store |
| 43 | Supply, installation, testing and commissioning of items in 33 KV C&R Panel of make OEM (The job includes identification of damaged part so that exact part can be arranged from OEM) |
| 44 | 3 Element Master Trip Relay ( 2NC+8NO for each element) |
| 45 | Single Element Master Trip Relay ( 2NC+8NO for each element) |
| 46 | TNC Switch 25 Amp. |
| 47 | Ampere meter with Selector switch Digital Programmable |
| 48 | Voltmeter with selector switch Digital |
| 49 | Tripping/Closing coils with housing complete 300 W Burden |
| 50 | Repairing of items in 33 KV C&R Panel. |
| 51 | Master Tripping Relay 4NO + 4NC, 36 Volt DC |
| 52 | TNC Switch 25 Amp. |
| 53 | Ampere meter with Selector switch Digital Programmable |
| 54 | Voltmeter with selector switch Digital |
| 55 | Supply,Installation, testing and Commissioning of various 33 KV VCB including supply of all accessories, clamps & collars for commissioning of VCB (along with GTP and Test Certificate) |
| 56 | Installation, testing and Commissioning of various 33 KV VCB including supply of all accessories, clamps & collars for commissioning of VCB |
| 57 | Supply,Installation, testing and Commissioning of various 33 KV C&R Panel including supply of all accessories, clamps & Stand for commissioning of C&R panel including Transportation from divisional store including earthing termination complete Job (along with GTP and Test Certificate) |
| 58 | Installation, testing and Commissioning of various 33 KV C&R Panel including supply of all accessories, clamps & Stand for commissioning of C&R panel including Transportation from divisional store including earthing termination complete Job. |
| 59 | Supply installation Testing & Commissioning of G I Pipe 9\\" Dia, 10 feet Long, 6mm thick along with Top end Base Plate (450mm x 450mm). |
| 60 | Supply installation Testing & Commissioning of G I Pipe 6\\" Dia, 10 feet Long, 6mm thick along with Top end Base Plate (450mm x 450mm). |
| 61 | Supply, installation, testing and commissioning of items of 33 KV VCB (The job includes identification of damaged part so that exact part can be arranged from OEM) |
| 62 | 33 KV Porcelain Post Insulator |
| 63 | Operating Rods |
| 64 | Closing Coils with Housing |
| 65 | Tripping Coils wih Housing |
| 66 | Contactor |
| 67 | Gasket |
| 68 | Operating Shaft |
| 69 | Mechanism Housing |
| 70 | Gear Assembly |
| 71 | vacuum/gas charging valve |
| 72 | Input/Output housing terminal pads |
| 73 | Repairing of items of 33 KV VCB |
| 74 | Operating Rods |
| 75 | Operating Shaft |
| 76 | Gear Assembly |
| 77 | Supply of 33 KV Vacuum Interrupters (1250A as per already installed) for below make. |
| 78 | Vijai, Easun Reyrolle, Alind, Alind, Electric Field, Pasca, Crompton, ABB, and out door type 11kv Breakers. |
| 79 | Sudhir, Schneider |
| 80 | Installation/Fixing, Testing & Commissioning of 33 KV Vacuum Interrupters of above makes including dismantling of damaged interrupter Including transportation of Red Material upto Divisional Store). |
| 81 | Supply of 33 KV vacuum Interrupters Housing of below mentioned make . |
| 82 | Vijai and Easun Reyrolle (Per Phase) |
| 83 | Alind (Assembly upper set/ Lower set). |
| 84 | ABB/Electric Field/Crompton/S&S ( per Phase) |
| 85 | Sudhir and Schneider (Per phase) |
| 86 | Outdoor type PCVCB upper and lower part(Per phase) |
| 87 | Installation, testing and commissioning of 33 KV vacuum Interrupters Housing of above mentioned make including dismantling of damaged assembly including transportation of Red material upto Divisional store. |
| 88 | Supply, installation, testing and commissioning of 33/11 KV Power Tranformer equipments/Items (The job includes identification of damaged part so that exact part can be arranged from OEM) including dismantelling of parts. |
| 89 | Bucholz Relay |
| 90 | 33KV Bushing |
| 91 | 33KV Bush Rods |
| 92 | 11 KV Bushing |
| 93 | 11 KV Bush Rods |
| 94 | Tap Changer complete |
| 95 | WTI set with probe |
| 96 | OTI set with probe |
| 97 | Repairing of 33/11 KV Power Tranformer equipments/Items |
| 98 | Bucholz Relay |
| 99 | Tap Changer complete |
| 100 | WTI set with probe |
| 101 | OTI set with probe |
| 102 | Installation, Testing & commissioning of Power Transformer including fixing of radiators (if required), topping up (oil to be provided by department) etc |
| 103 | 1 MVA OR of lower capacity |
| 104 | 3.15 MVA |
| 105 | 4 MVA |
| 106 | 5 MVA |
| 107 | 6.3 MVA |
| 108 | 10 MVA |
| 109 | Dehydration/Filteration of Power Transformer Oil including providing of Filtration machine capable of centrifuge, heating, degassing, filtration value upto level load. |
| 110 | Installation, Testing and Commissioning of following MCCB's with copper spreaders ISI Mark. |
| 111 | 100A 3-pole 36 KA |
| 112 | 125A 4-pole 36 KA |
| 113 | 250A 4-pole 36 KA |
| 114 | 400A 4-pole 36 KA |
| 115 | 630A 4-pole 36 KA |
| 116 | Supply, Installation, Testing and Commissioning of MCCB Enclosure Box |
| 117 | Providing and fixing of Gaskets of 12mm,10mm,6mm including drainage of oil (if reqd.), Dismantling of damaged gaskets/oil sealings and vice-versa of same after completing the job by way of dismantelling of transformer parts and Re-fixing of same. |
| 118 | Radiator valve Gasket (12mm) |
| 119 | Top cover peripheral gasket (12mm) |
| 120 | Oil Sealing of HV-LV Bushings |
| 121 | Tap Changer Body gasket (12mm) |
| 122 | Sight glass (6mm) |
| 123 | Inspection Plate (6mm) |
| 124 | 33KV outdoor CT Gaskets (10mm) |
| 125 | Supply , Laying testing & commisioning of 33 KV 3 core XLPE Cable along with suitable heat shrinkable/push on cable termination kits (Make-3M/ Polycab/ Anchor/ Havells/ Gloster) |
| 126 | 300 sqmm |
| 127 | 120 sqmm |
| 128 | Supply , fixing, testing & commisioning of 3 Core 33 KV Jointing Cable kits for XLPE cable of sizes |
| 129 | 400 sqmm |
| 130 | 300 sqmm |
| 131 | 120 sqmm |
| 132 | Supply & Fixing of Heat shrinkable/ Push on cable kits with allied accessories Suitable for 33 KV 3-core XLPE cable including dismantling of existing damaged cable kits of following sizes |
| 133 | 400 sq.mm |
| 134 | 300 Sq.mm |
| 135 | 120 Sq.mm |
| 136 | Supply , Laying testing & commisioning of 11 KV 3 core XLPE Cable along with suitable heat shrinkable/push on cable termination kits (Make-3M/ Polycab/ Anchor/ Havells/ Gloster) |
| 137 | 120 sqmm |
| 138 | 185 sqmm |
| 139 | 240 sqmm |
| 140 | 300 sqmm |
| 141 | 400 sqmm |
| 142 | 630 sqmm |
| 143 | Supply , fixing, testing & commisioning of 3 Core 11 KV Jointing Cable kits for XLPE cable (Make-3M/ Polycab/ Anchor/ Havells/ Gloster) |
| 144 | 120 sqmm |
| 145 | 185 sqmm |
| 146 | 240 sqmm |
| 147 | 300 sqmm |
| 148 | 400 sqmm |
| 149 | 630 sqmm |
| 150 | Fixing of 11 KV Heat shrinkable cable kits with allied accessories Suitable for 3-core XLPE cable including dismantling of existing damaged cable kits of following sizes |
| 151 | 185 Sq.mm |
| 152 | 240 Sq.mm |
| 153 | 300 Sq.mm |
| 154 | 400 Sq.mm |
| 155 | 630 Sq.mm |
| 156 | Providing and fixing of 1'x1'Junction box of 14 SWG IP 65 protected as per Bis with inbuilt 36 No's Brass connectors mounted on din rail channels complete. |
| 157 | Oil topping of equipments including Power Transformers, CT's, PT's and auxillary X-mers. |
| 158 | Rectification of minor leaks of Power Transformers, CT's, PT's and auxillary X-mers. |
| 159 | Supply & fixing of following battery charger accessories including dismantling & Modification of damaged accessories/ Items. (The job includes identification of damaged part so that exact part can be arranged from OEM) |
| 160 | Power Diodes P-type/ N-type ( 40 to 100 A) |
| 161 | Charger Coil 240/36V AC |
| 162 | AVR Cord |
| 163 | DC Voltmeter ( 0-60V) Digital |
| 164 | DC Ampere meter (0-50A) Digital |
| 165 | Variac 15/25 Amp, 0-240 A |
| 166 | Repairing of following battery charger accessories |
| 167 | DC Voltmeter ( 0-60V) Digital |
| 168 | DC Ampere meter (0-50A) Digital |
| 169 | Variac 15/25 Amp, 0-240 A |
| 170 | Supply, laying, routing, installation, testing & Commissioning of damaged panel wiring using multistandard wire of sizes 1.5/2.5 sqmm including ferruling, thimbling etc |
| 171 | Installation, testing commissioning of 33/0.433 KV Transformer equipments (if required) fixing of following items |
| 172 | 0.433 KV LV Bushing |
| 173 | 0.433 KV Bush rods |
| 174 | Supply, Routing, laying, testing and commissioning of 2.5 mm² Control cable copper Armoured , 1.1 kV Grade, ISI, FRLS , connecting ribs, bunching wire, ferruling, thimbling etc |
| 175 | 12 Core . |
| 176 | 8 Core |
| 177 | 6 Core |
| 178 | 4 Core |
| 179 | 2 Core |
| 180 | Supply, Laying, installation, testing and commissioning of Chemical Earthing including digging of pits including connecting with present earthing complete job which includes 3m Copper in GI electrode 43mm diameter and termination using 40*6mm GI strip with mainhole cover |
| 181 | Supply, Fixing, Fabrication, testing, commissioning of mechanical parts for various 11kV VCB's (including dismantling of assembly and damaged parts and refixing as per requirement to existing breakers (Pascal, Electric field, Schneider, ER, Alind, CG etc) |
| 182 | Spring charging mechanism with allied accessories complete set of assembly for different 11kv vcb's |
| 183 | HSS Gears of sorts for different sizes and applications used in VCB's of different make |
| 184 | Close release steel pins of sorts |
| 185 | Trip release steel pins of sorts |
| 186 | locking cam set of sorts |
| 187 | Rack and pinion set |
| 188 | Torsion springs of sorts |
| 189 | operating rod of sorts |
| 190 | operating corn of sorts |
| 191 | Making/Breaking springs of sorts |
| 192 | loading spring of sorts with dampers |
| 193 | epoxy holding insulators |
| 194 | Main Links |
| 195 | copper flexible ribbon/braid connections |
| 196 | Copper finger contact 8mm french curved single type |
| 197 | copper 12 finger contact |
| 198 | Bunched strip copper contact for alind |
| 199 | Spring charging Ratchet gear assesmbly with lever and gear complete |
| 200 | Trippin coil housing with allied accessories of sorts |
| 201 | Closing coil housing with allied accessories of sorts |
| 202 | Expoxy/porcelain spout with copper bus bars of sorts of all kinds of breaker excluding Alind make |
| 203 | Expoxy/porcelain spout with copper bus bars with inbuild CT Alind make. |
| 204 | Cotter pins of sorts HSS |
| 205 | Cotter spring pins HSS |
| 206 | Dowell Steel pins |
| 207 | Shaft locks/Pin Locks |
| 208 | Trip strike lever of sorts |
| 209 | Close strike lever of sorts |
| 210 | Minor Re-alignment/Readjustment of mechanical parts |
| 211 | DC Sprng Charging motors 25 to 250 V DC |
| 212 | DC Sprng Charging motors 240V AC |
| 213 | Repairing of mechanical parts for various 11kv VCB's (including dismantling of assembly and damaged parts and refixing as per requirement to existing breakers (Pascal, Electric field, Schneider, ER, Alind, CG etc) |
| 214 | Spring charging mechanism with allied accessories complete set of assembly for different 11kv vcb's |
| 215 | Supply, Fixing, Fabrication, testing, commissioning and repairing of Electrical parts/ Circuits for various 11kv/33KV VCB's (including dismantling of damaged Electrical parts/Circuits and refixing by way of re-wiring as per requirement to existing breakers/Pannels (Pascal, Electric field, Schneider, ER, Alind, CG etc) |
| 216 | 12 Point Male female control circuit contact |
| 217 | 24 Point Male female control circuit contact |
| 218 | 36 Point Male female control circuit contact |
| 219 | Auxillary Switch 12 No+12 NC 16-25A with lever |
| 220 | Auxillary Switch 8 No+8 NC 16-25A with lever |
| 221 | Auxillary Switch 6 No+6 NC 16-25A with lever |
| 222 | Anti pumping device with allied accessories |
| 223 | Limit switch with 2 No+2Nc 16-25A with accessories |
| 224 | Repairing of Trip circuit super vision circuit |
| 225 | Reparing of Closing circuit |
| 226 | 36 VDC Master trip relay with 4 NO+4NC 25A High speed |
| 227 | 36VDC Auxilliary relay with 4NO+4NC High speed |
| 228 | Driver relay DPDT 12 vdc with 2 NO+NC High speed |
| 229 | 11KV/110v based 4\\" Voltmeter digital programeable type |
| 230 | CT Ratio Based 4\\" Amp. Meter digital programeable type |
| 231 | ASS Switchs 25A |
| 232 | VSS Switchs 25A |
| 233 | LED indicators of different colors 36 VDC |
| 234 | Push buttons 25A with 2NO+2NC |
| 235 | MCB's of sorts 2A-32A 10KA c curve type |
| 236 | Repairing of Pannel wiring complete job as per REC Standards. |
| 237 | Installation Testing and commissioning of Tri-vector meters |
| 238 | Supply, Testing and commissioning of Control relays with 3OC+1EF 2 Element based digital including necessary modification and minor wiring works complete job of following make. |
| 239 | MIT- 114/104 (ER) make. |
| 240 | Schneider |
| 241 | Crompton 14C |
| 242 | Ashida ADR241B/242B |
| 243 | Simens 7SR |
| 244 | Ashida 131A |
| 245 | Ashida 141 |
| 246 | LNT M314A |
| 247 | Supply, Installation, testing and commissioning of 11KV epoxy compound spouts with required Copper busbar as per requirement and as per the existing pannel requirement of below mentioned make including dismantling of damaged spouts including transportation of Red material upto Divisional store. |
| 248 | Vijai (Per Phase) |
| 249 | Alind (Sput with required CT/phase). |
| 250 | Easun Reyrolle ( per Phase) |
| 251 | ABB ( per Phase) |
| 252 | ABB (Per Set) |
| 253 | S&S ( per Phase) |
| 254 | Electric Field ( Per Phase) |
| 255 | Electric Field ( Per Set) |
| 256 | Crompton ( Per Phase) |
| 257 | Crompton ( Per Set) |
| 258 | Sudhir/Schneider (Per phase) |
| 259 | Sudhir/Schneider (Per Set) |
| 260 | Hartek (Per Phase) |
| 261 | Hartek (Per Set) |
| 262 | Supply installation testing and commisioning of following tripping and closing coils for different types of VCB's including dismantling of existing damaged coils. The Tripping and closing coils must have burden between 250 to 350 watts at 30VDC & must follow the specifications of design of VCB's . |
| 263 | Tripping/Closing coil of 11KV Alind make VCB |
| 264 | Tripping/Closing coil of 11 KV ER/Vijai Make VCB |
| 265 | Tripping/Closing coil of 11KV Electric Field Make VCB |
| 266 | Tripping/Closing coil of 11KV ABB Make VCB |
| 267 | Tripping/Closing coil of 11KV Crompton Make VCB |
| 268 | Tripping/Closing coil of 11KV Stelmac Make VCB |
| 269 | Tripping/Closing coil of 11KV Sudhir/Schneider Make VCB |
| 270 | Tripping/Closing coil of 11KV Pascal Make VCB |
| 271 | Tripping/Closing coil of 33KV ABB Make VCB |
| 272 | Tripping/Closing coil of 33KV Crompton Make VCB |
| 273 | Tripping/Closing coil of 33KV Stelmac Make VCB |
| 274 | Tripping/Closing coil of 33KV Megawin Make VCB |
| 275 | Installation, Testing, and commissioning of tripping and closing coils for different types of VCB's including dismantling of existing damaged coils. The Tripping and closing coils must have burden between 250 to 350 watts at 30VDC & must follow the specifications of design of VCB's . |
| 276 | Supply installation testing and commisioning of |
| 277 | 33 KV Lightining Arrestor (33kV , 10KA) |
| 278 | 11 KV Gapeless surge arrestor, 9KV , 10KA LA |
| 279 | Installation testing and commisioning of |
| 280 | 33 KV LA |
| 281 | 11 KV LA |
| 282 | Providing & Fixing of |
| 283 | 3/5 15 AMP socketwith switch |
| 284 | 3/5 6 AMP socket |
| 285 | 6 Amp switches |
| 286 | Lamp Holders |
| 287 | 12 V DC emergency Lamp |
| 288 | Fan dimmer |
| 289 | 9/15 W LED Lamps |
| 290 | 1400 mm Ceiling Fan |
| 291 | 200 mm Exhaust Fan |
| 292 | 6-32 Amp MCB |
| 293 | 40 Amp MCB |
| 294 | 25 Amp Industrial type Plug Socket with MCB in MS box |
| 295 | Providing and laying of Insulating HT Rubber Mats ( 1000x 2500) 12 to 25 mm thick |
| 296 | Providing and laying of 2 core 16 sqmm 1.1 KV PVC cable for AC / DC distribution including Termination |
| 297 | Supply, installation, testing and commissioning of Following items for use in both 11KV VCB Panel & 33KV C&R Panels |
| 298 | BMR mechanism of different makes |
| 299 | Shower contact |
| 300 | Selector switch 16 Amp |
| 301 | Trip circuit supervision Relay |
| 302 | Indication LED's of various colors |
| 303 | Buzzer |
| 304 | Supply, installation, testing and commissioning of OLTC Panel for Power Transformers |
| 305 | Supply, installation, testing and commissioning of XLPE LT Cable 3.5 Core, armoured, Fire resistant of sizes |
| 306 | 95 sq.mm |
| 307 | 120 sq.mm |
| 308 | 185 sq.mm |
| 309 | 240 sq.mm |
| 310 | 300 sq.mm |
| 311 | 400 sq.mm |
| 312 | Loading Transportation and unloading at site of work from Divisional stores |
| 313 | 33KV VCB/ 33KV C&R Panel/ 11 KV VCB Panel |
| 314 | 33KV CT/PT Set |
| 315 | Transportation of 11KV VCB to the workshop of the contractor and back to the Receiving station in case the repairing of 11KV VCB is not possible at site. |
| 316 | Carriage of Major Red Materials from Site to Store including unloading |
| 317 | 11KV Pannels |
| 318 | C&R Pannels |
| 319 | 33 KV CT |
| 320 | 33KV PT |
| 321 | 33KV/ 11 KV isolators and small item battery etc |
| 322 | Damaged Cable |
| 323 | Ac/DC Board |
| 324 | 7.5 KV, 90-240 , Servo Stablisers |
| 325 | SITC of following Items |
| 326 | 11 kV Isolator, Double Break,3-pole, 630Amp, horizontal mounting Type, with Earth Switch. |
| 327 | 800 AMP 11 KV Isolator without Earth balde |
| 328 | 33 kV Isolator with Earthing Blade (36kV,800A, Outdoor,3 poles, 25 kA) |
| 329 | 33 kV Isolator without Earthing Blade (36KV,800A,Outdoor,3 poles,25 KA) |
| 330 | 33 kV Lightening Arrestors (33 kV, 10kA, Station class, ZnO, Polymer) gap less (1 No. per Φ) |
| 331 | 33 kV 10kN Polymer Post Insulator 36kV,170kV Impulse, creepage distance 1224m |
| 332 | 33 kV 10kN porcelene Post Insulator 36kV,170kV Impulse, creepage distance 1224m |
| 333 | 11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp |
| 334 | 120 mm² XLPE LT Cable 4 Core, armoured, FRLS |
| 335 | MCCB ‐ 160 Amps , 36 kA, 4P Ics =100% Icu at 415 (kA rms) |
| 336 | 11 kV Horn Gap Fuse Set 3 Phase 200A |
| 337 | 8 Pin Plug in relay DC- 24 t0 36 Volt , 10-25 AMP |
| 338 | 8 Pin Plug in relay AC- 240 Volt , 10-25 AMP |
| 339 | 3 element Auxlary relays , ABB for Trf protection |
| 340 | 6 Way Multi-way Microprocessor based electronic Annunciator to be programmable for at least two types of sounds) for the visual and audible alarm with built-in watch dog. it shall have provision for connection with accept/reset/lamp test/mute Push buttons for proper functions. Electronic annunciator shall have provision for connection with Electronic Buzzer/Electronic Bell for Trip & Non-Trip Audio Alarm of common annunciation scheme.it should have separate colored windows for Trip & Non-Trip Annunciation for easy detection. Annunciator fascia units shall have translucent plastic windows for each alarm point.Electronic Annunciator shall have first Fault Indication Facilities & System Watch Dog. Annunciator fascia plate shall be engraved in black lettering with respective alarm inscription, size of the lettering shall be about 5 mm. The inscriptions shall be visible only when the respective fascia LED will glow.one alarm buzzer meant for non-trip alarms and one bell meant for trip alarms shall be provided.Control Voltage 30 V DC+/-25%. 2 No.,s of LEDs per window |
| 341 | 16 Way Multi-way Microprocessor based electronic Annunciator to be programmable for at least two types of sounds) for the visual and audible alarm with built-in watch dog. it shall have provision for connection with accept/reset/lamp test/mute Push buttons for proper functions. Electronic annunciator shall have provision for connection with Electronic Buzzer/Electronic Bell for Trip & Non-Trip Audio Alarm of common annunciation scheme.it should have separate colored windows for Trip & Non-Trip Annunciation for easy detection. Annunciator fascia units shall have translucent plastic windows for each alarm point.Electronic Annunciator shall have first Fault Indication Facilities & System Watch Dog. Annunciator fascia plate shall be engraved in black lettering with respective alarm inscription, size of the lettering shall be about 5 mm. The inscriptions shall be visible only when the respective fascia LED will glow.one alarm buzzer meant for non-trip alarms and one bell meant for trip alarms shall be provided.Control Voltage 30 V DC+/-25%. 2 No.,s of LEDs per window |
| 342 | Hooters for trip alarm |
| 343 | Bell for DC & AC Fail |
| 344 | LED semaphone for Breaker for C&R Pannels ( The semaphore indicators shall be three position type, having one intermediate position to indicate the \\"DCsupply fail\\" condition) |
| 345 | LED semaphone for Isolator with Earth balde for C&R Pannels |
| 346 | LED semaphone for Isolator without Earth balde for C&R Pannels |
| 347 | Push Buttons |
| 348 | Cubical Illuminating Lamps 9- 18 watt LED |
| 349 | Pannel thermo stat |
| 350 | AC Fail & DC Fail Relays ( 80C & 80D) |
| 351 | Pannel Heaters |
| 352 | 2 -16 AMP cartiridge fuses |
| 353 | Rating Kit Kat fuses with base |
| 354 | terminal blocks |
| 355 | terminal blocks stud type 2.5mm |
| 356 | CT & PT Marshalling Box with 36 Teminal blocls |
| 357 | 1250 Amp Flexible Copper Jumpers (bread tye ) |
| 358 | 3Phase CT Based Voltmeter, Ampere meter and multifunctional meter should be used of size96 x96 with accuracy class of CL-0.5 |
| 359 | 11 KV porceline pannel insulators |
| 360 | 50 mm dia .10mm thick alimunium IPS Tubes |
| 361 | 50 mm dia .10mm thick alimuniom IPS Tubes Tubes jointors |
| 362 | Transfromer LT Distribution Box for:- 100 kVA DTR with 160 Amp MCCB 3P 16 kA for incomer & 100 Amp MCCB 3P 16 kA 2 No.s for Outgoing Circuits. , 3Pase , with indicators , Neutral Bus Bar, & Volt meter |
| 363 | LT Cable 3.5 core sqmm 70 Sqmm |
| 364 | LT Cable 3.5 core sqmm 95 Sqmm |
| 365 | 1.1 kV Heat Shrinkable Cable Termination Kits (Indoor/Outdoor) |
| 366 | 4NO+4NC auxilary contact with rod |
| 367 | 6NO+6NC auxilary contact with rod |
| 368 | 8NO+8NC auxilary contact with rod |
| 369 | 12NO+12NC auxilary contact with rod |
| 370 | 24 male female contract for 11 KV Pannel |
| 371 | 5-10 Amp Limit switches |
| 372 | Pannel Motors |
| 373 | 30 to 250 volt Brige Rectiifes for motors |
| 374 | 2\\", 3HP dewartering Pump along with all accessiries line delivery pipe,Starter, suction pipe & fiundation ,Cabling etc |
| 375 | 32Amp , 3 Phase , DC 24-250 Volt Contactors |
| 376 | 32Amp , 3 Phase , AC 240 Volt Contactors 3 Pole Power Contactors - Type MNX-22 |
| 377 | Limit Switchs wuth 2 No+ 1 NC contacts |
| 378 | Distribution Panel (415 V, AC) made of CRCA thickness not less than 2mm. Powder Coated, degree of protection IP43. 200 Amps Switch Fuse disconnector for incoming supply and 5 No TPN MCB's (16-125 Amps ) and 5 No DP MCBs (0-32A), rectangular busbar suitable for 200 Amps continuous Supply including indication lamps and cables and other accessories |
| 379 | Distribution Panel (30 V, DC) made of CRCA thickness not less than 2mm. Powder Coated, degree of protection IP43 for 2 No battery incoming supply with 2 No 63 Amps DP MCBs for incoming supply Double busbar of adequate size, 12 No DP DC MCB (0-32A) including indication lamps and cables and other accessories |
| 380 | Yard Lighting by way of Providing 12.5 Mtr motorised High Mast with 4 No.s of 200 W LED flood lights on each High Mast complete with earthing , and foundations |
| 381 | 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC)Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required |
| 382 | 2x 16 sqmm 1.1 KV aroured Cable |
| 383 | 12 x5mm copper Battery connector |
| 384 | Chequered Plates 6mm thick MS |
| 385 | Rubber Mat 1mx2m 19mm thick |
| 386 | 300mm Heavy Duty Exhuast Fan |
| 387 | SITC of Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. Group A |
| 388 | SITC of Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 389 | SITC of Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required |
| 390 | 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 391 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 392 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 393 | 2 X 6 sq. mm + 1 X 6 sq. mm earth wir |
| 394 | 2 X 10 sq. mm + 1 X 6 sq. mm earth wir |
| 395 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required |
| 396 | 5/6 amps switch |
| 397 | 15/16 amp switch |
| 398 | 3 pin 5/6 amp socket outlet |
| 399 | 6 pin 15/16 amp socket outlet |
| 400 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 401 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required |
| 402 | 1 or 2 Module (75mmX75mm) |
| 403 | 3 Module (100mmX75mm) |
| 404 | 4 Module (125mmX75mm) |
| 405 | 6 Module (200mmX75mm) |
| 406 | 8 Module (125mmX125mm) |
| 407 | 12 Module (200mmX150mm) |
| 408 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. |
| 409 | Supplying and fixing suitable size GI box with modular plate and cover in FRLSont on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required |
| 410 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted includingearthing etc. as required |
| 411 | 8 way, Double door |
| 412 | 12 way, Double door |
| 413 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without CB/RCCB/Isolator) |
| 414 | 4 way (4 + 12), Double door |
| 415 | 6 way (4 + 18), Double door |
| 416 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, 10 kA, “C” curve,miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required |
| 417 | Single pole |
| 418 | Double pole |
| 419 | Triple pole and neutral |
| 420 | Supplying and fixing 30 amps, 415 volts, TPN industrial type, socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 30 amps “C” curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. asrequired. |
| 421 | Supply installation Testing and commissioning of |
| 422 | 18 Watt LED Lamps |
| 423 | Chargable DC lights |
| 424 | Feeder Name Board |
| 425 | Danger Board |
| 426 | 36 Volt , 1NC+3No 24-26 Volt Relay 10 Amp |
| 427 | 11 KV Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, Stn. Type |
| 428 | G.I Steel of all sorts |
| 429 | 150 mm GI Pipe with reqd. Number of collars (6\\") |
| 430 | Anti-Climbing Device with Clamps |
| 431 | Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 3 mtr long through GI Strip (25x3)mm |
| 432 | Rotary /Selector switch Voltage between Phases with OFF 16amp |
| 433 | Rotary /Selector switch Voltage between Phases & individual Phase to Neutral with OFF 16amp |
| 434 | Rotary /Selector switch Line Currents with OFF with CT |
| 435 | Breaker Control Switches (Trip - Neutral - Close) 1Trip + 1Close 25AMP |
| 436 | Breaker Control Switches (Trip - Neutral - Close) 2Trip + 2Close 25AMP |
| 437 | QuartzTime Switch ,240 VAC Base/DIN Mounting |
| 438 | Digital Time Switch ,24 VDC 1 C/O Base/DIN 25 ON/OFF Each |
| 439 | Standard Illuminated Actuators With LED [8531) Twin Touch Y-Yellow A-Amber |
| 440 | Standard Push Button Actuators Ø 22.5 mm |
| 441 | Mushroom Head Actuator ‘Push Turn Type’with Legend - STOP Contact - 1 ‘NC’ for Stop |
| 442 | Pannel indicators Gen Next Pro LED Indicator 22.5 mm( Red, Green ,Yellow & A-Amber ) 24 - 48V DC ,240VAC |
| 443 | Pannel indicators Gen Next Pro LED Indicator 22.5 mm( Blue & White ) 24 - 48V DC ,240VAC |
| 444 | Pannel indicators Gen Next Pro LED Indicator 22.5 mm( Red, Green ,Yellow & A-Amber ) 24 - 48V DC |
| 445 | LATCHING FLUSH PUSH BUTTONS with 1NO+1NC |
| 446 | TWIN ACTUATORS Control & Signalling Devices 22.5 Ø Double Flush with IO Mark Plastic |
| 447 | TWIN ACTUATORS Control & Signalling Devices 22.5 Ø Double Flush with IO Mark and WITH LED Metal |
| 448 | TimeDelay relay TDR 240 VAC/24 VAC/DC |
| 449 | HRC fuse 2- 32 Amp CNS (Off Set) clip in Type |
| 450 | HRC fuse 2- 32 Amp |
| 451 | Fuse holders & Fuse bases suitable 2-32 Amp |
| 452 | Porcelain Rewirable Fuse Holder (Kit-Kat |
| 453 | 3Phase volt meter 3 line display |
| 454 | 3Phase Ampere meter 3 line display |
| 455 | VAF meter |
| 456 | Limit Switch With Push Rod & PlasticProtective Cover 1 NO+ 1 NC |
| 457 | Junior Stroke Counter |
| 458 | Limit Switch With Push Rod & PlasticProtective Cover 2NO + 2NC 1436 |
| 459 | Copper Brushes for Spring charging motor |
| 460 | solder less Terminals |
| 461 | Insulated Ring Terminals 3.7 to 6.4 mm |
| 462 | Insulated Spade Terminals 3.7 to 6.4 mm |
| 463 | Insulated Pin Terminals 1.7 to 2.7 mm |
| 464 | HRC fuses (BS) 3NW Blade tag type 0.5 to 16Amp |
| 465 | HRC fuses (BS) 3NW Blade tag type 25 to 32Amp |
| 466 | Fuse holders 3NW type |
| 467 | 7PJ Trip Relays 7PJ1321-5AA21-0AA0 TCS relay, 2CO, SR, Aux 24-240VAC/DC, BI 24-240VDC |
| 468 | 7PJ Trip Relays 7PJ1212-6EB01-0AA0Trip relay with hand reset contacts with flag, DC 24-48, 4NO+1NC, high burden |
| 469 | 7PJ Auxiliary Relays 7PJ1132-6CA00-0AA0Auxiliary relay Three Element, hand reset with flag, 24-48 DC, 2NO, Low burden |
| 470 | 7PJ Auxiliary Relays 7PJ1111-6DA20-0AA0Auxiliary relay Single Element with self reset contacts with flag, 110V DC, 3NO+2CO,Low burden |
| 471 | Auxiliary Contactors , 3RH2 (S00) with “Mechanically linked contact elements” with AC coil ( 3NO+1NC) |
| 472 | Auxiliary Contactors , 3RH2 (S00) with “Mechanically linked contact elements” with DC coil ( 3NO+1NC) |
| 473 | Supply of following items |
| 474 | Supply of PORTABLE 5KW PETROL GENSET with FUEL CONSUMPTION 2L/HOUR(APPROX) Mileage) FUEL TANK CAPACITY: 25L NOISE LEVEL:85DB(APPROX) |
| 475 | 250A Stick Welder, 220V MMA Welding Inverter Gasless Tool, IGBT Inverter Welding Machine, Portable Mini MMA Welder Machine with Digital LED Display, Arc Force, Hot Start, Anti-Stick |
| 476 | Hydraulic Crimping Tool 10 Tons Battery Cable Lug Terminal Crimper |
| 477 | Gas Can Butane/LPG Single Nozzle With 1Pc Torch Gun + Butane Can 500ML |
| 478 | Brush Cutter 52cc 2 Stroke 2.4 HP Petrol Engine Heavy Duty Grass Trimmer with 80T Blade Chain Head and Trimmer Attachments |
| 479 | suction pump 5 HP |
| 480 | Havells 100W LED Flood Light, Centura Neo 6K IP66 Waterproof Led Lights with 120° Wide Beam-LED Lamp Lights for Yard, |
| 481 | STRONG WAVE Ultrasound Rat Repellent |
| 482 | Portable 12mm Drill |
| 483 | Magnetic Drill |
| 484 | Pulling Machine /Turfer along with Camlog suitable upto 200 sqmm ACSR |
| 485 | Pulling Machine /Turfer with Chain Pulley along with Camlog suitable upto 200 sqmm ACSR |
| 486 | Grinder Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail