| 1 | S&F IN REPAIR Digital Multifunction Meter with showing V, A, F, PF, kW, kVA, kVAR, kWh, Kvah, kVARh, Runhour, one hours phase angle, Inturrupts, THD, Evens (high-Low), Neutral cutterny, accurancy, etc., complete all as specified. |
| 2 | Excavation in trenches not exceeding 1.5m wide and not exceeding 10 Sq.m on plan area and not exceeding 1.5m deep in any type of soil, for laying of cable/pipes etc., including taking out old bricks and separating serviceable & unserviceable bricks, cleaning & stacking serviceable bricks for re-use, complete all as specified. |
| 3 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick of excavated soil, as in any type of soil, complete all as specified. Note: A deduction of 10% shall be made from total computed volume of filling to cater in bulk irrespective of machinery used for ramming. |
| 4 | Removal of excavated material [Soil] to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point, complete all as specified. |
| 5 | Supply and laying in REPAIR Un-reinforced Precast Cement Concrete Cable Covers, Class LV, Type - 1 flat, size 250mm X 150mm X 40mm in trenches for cable protection, embossed with \\"ELECTRIC\\" on the top surface, complete all as specified and as directed. |
| 6 | M&L for Dry & clean river sand cushioning in two layers, first layers of 80mm thick before laying of cable and second layer of 150mm thick after laying of cable, levelled and punned down to a depth of 100mm above the top of the upper-most cable, for cable protection in trenches, complete all as specified and as directed. Note: The punned down thickness shall be measured for payment. |
| 7 | M&L for PCC type B1 [1:2:4] using 20mm graded granite stone aggregate) as in copings, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, finished plain fair faces, complete all as specified and as directed. |
| 8 | M&L PCC 1:3:6 type C2 (using 40mm graded granite stone aggregate) as in foundation, filling and mass concrete, complete all as specified and as directed. |
| 9 | S&F IN REPAIR GI pipe light grade pipe 50mm dia for cable protection, laid in trenches /pole / walls / road etc., complete all as specified. |
| 10 | S&F IN REPAIR GI pipe light grade pipe 80mm dia for cable protection, laid in trenches /pole / walls / road etc., complete all as specified. |
| 11 | M&L for Cutting existing road upto 0.75m deep x 0.45m width for laying UG cables of any size, with and including making good the disturbed top surface with 150mm thick PCC 1:2:4 type B1 and earthing filling with and including removing surplus soil to a distance not exc 50m, complete all as specified and as directed. Note: Location of cutting road shall be as directed by Engineer-in-Charge and noting shall be paid for change in strata if any at site. |
| 12 | Supply, laying, testing and commissioning of LT XLPE insulated, screened with extruded PVC inner sheathed, PVC bedded, galvanised steel strip armoured electric power cable [heavy duty] of size 4.0core x 10.00Sqmm, with stranded aluminium conductor, 1100 volts grade, suitable for earthed system with and including cable glands, ferrules and connected accessories, laid in trenches or ducts or through the pipe etc., including taking down old u/s cable, complete all as specified. Note: Necessary excavation & earth work, brick protection & sand cushioning shall be measured and paid separately under respective items. |
| 13 | All as per Serial Item No. 12 here-in-before but for cable of size 4.0core x 16.00Sqmm. |
| 14 | All as per Serial Item No. 12 here-in-before but for cable of size 4.0core x 25.00Sqmm. |
| 15 | All as per Serial Item No. 12 here-in-before but for cable of size 3.5core x 50.00Sqmm. |
| 16 | All as per Serial Item No. 12 here-in-before but for cable of size 3.5core x 70.00Sqmm. |
| 17 | All as per Serial Item No. 12 here-in-before but for cable of size 3.5core x 95.00Sqmm. |
| 18 | All as per Serial Item No. 12 here-in-before but for cable of size 3.5core x 120.00Sqmm. |
| 19 | All as per Serial Item No. 12 here-in-before but for cable of size 3.5core x 150.00Sqmm. |
| 20 | All as per Serial Item No. 12 here-in-before but for cable of size 3.5core x 185.00Sqmm. |
| 21 | All as per Serial Item No. 12 here-in-before but for cable of size 3.5core x 240.00Sqmm. |
| 22 | All as per Serial Item No. 12 here-in-before but for cable of size 3.5core x 300.00Sqmm. |
| 23 | All as per Serial Item No. 12 here-in-before but for cable of size 3.5core x 400.00Sqmm. |
| 24 | Supply and laying in repair DWC HDPE Pipe 40mm dia, with ISI marked (IS 14930 Part-1&2), laid in trenches / floors & fixed on wall/ pole with and including necessary fittings such as bends, sockets & other connected accessories etc for laying of electric cables / road crossings etc., complete all as specified. |
| 25 | Supply and laying in repair DWC HDPE Pipe 60mm dia, with ISI marked (IS 14930 Part-1&2), laid in trenches / floors & fixed on wall/ pole with and including necessary fittings such as bends, sockets & other connected accessories etc for laying of electric cables / road crossings etc., complete all as specified. |
| 26 | Supply and laying in repair DWC HDPE Pipe 150mm dia, with ISI marked (IS 14930 Part-1&2), laid in trenches / floors & fixed on wall/ pole with and including necessary fittings such as bends, sockets & other connected accessories etc for laying of electric cables / road crossings etc., complete all as specified. |
| 27 | Taking out under ground LT cables, different sizes, by excavation and earth work in any type of soil, removing bricks or PCC tiles of any size, re-laying in the same trenches or re-routing after rectification of fault as required, complete all as specified.NOTE:- (i) Joints & Jointing materials, new cable, additional bricks/PCC Covers, sand shall be measured & paid for separetely.(ii) Retrieved serviceable bricks or PCC cable cover and sand shall be re-laid on the cable & the cost for the same is deemed to be included in the unit rate. |
| 28 | S&F IN REPAIR XLPE LT straight through cable jointing kit, heat shrink type joint for 1.1KV (Earthed) grade cable with jointing material and accessories, suitable for 4/3.5 core XLPE armoured aluminium conductor cable of size 6sqmm to 16 sqmm, complete all as specified. |
| 29 | All as per Serial Item No. 28 here-in-before but suitable for cable of size 25 to 50Sqmm. |
| 30 | All as per Serial Item No. 28 here-in-before but suitable for cable of size 70 to 120Sqmm. |
| 31 | All as per Serial Item No. 28 here-in-before but suitable for cable of size 150 to 185Sqmm. |
| 32 | All as per Serial Item No. 28 here-in-before but suitable for cable of size 240 to 300Sqmm. |
| 33 | All as per Serial Item No. 28 here-in-before but suitable for cable of size 400 to 500Sqmm. |
| 34 | S&F MCB SP 06 to 32Amp, 10kA, 230Volt, B curve with necessary connecting up in MCB DB, testing and commissioning, complete all as specified and as directed. |
| 35 | M&L for Crushed stone aggregate of size 20mm in compacted thickness of 75mm laid over and including a sand cushioning layer of 50mm thick, with and including providing plastic sheet of heavy duty with water proof quality 100GSM as weed control barrier sheet in between the stone aggregate & sand layer, complete all as specified and as directed. |
| 36 | M&L for Earth continuity conductor or main earthing lead of size 32 x 6mm Aluminium strip for connection, fixed to wall on batten on recess or chases or buried in ground or dawn in conduit / pipe or fixed to poles or any other indicated situation for loop earthing etc. as required, completion all as specified and as directed. |
| 37 | M&L for dismantling the RMU, LT panel , TRANSFORMER, from all electric cable and removing all earthing strips and dismantling all fastner arrangements safely and taking out from its original location and shifting the RMU panel from to the location not more than 5 km using telescopic hydra as detailed by the engineer -in -charge and fixing all HT/LT cable as detailed including re connecting the earth strips and internal wiring and fastner arrangements as required at site, complete all as specified and as directed. |
| 38 | M&L for Minor welding work on hinges, corner sides of LT panels of any size, including rent of welding machine and cost of welding rod etc., complete all as specified and as directed. |
| 39 | S&F IN REPAIR APFC relay, 8 Stage, auto set function, having digital display, complete all as specified and as directed. |
| 40 | S&F IN REPAIR APFC relay, 12 Stage, auto set function, having digital display, complete all as specified and as directed. |
| 41 | S&F IN REPAIR APFC relay, 16 Stage, auto set function, having digital display, complete all as specified and as directed. |
| 42 | S&F Current Transformer 400/5A to 800/5A Class 1, VA 15 50Hz complete, with and including removing existing unserviceable CT of any size, complete all as specified and as directed. |
| 43 | S&F Current Transformer 2000/5A Class 1, VA 15 50Hz complete, with and including removing existing unserviceable CT of any size, complete all as specified and as directed. |
| 44 | M&L for Tracing out fault in 11 KV / 440KV UG HT/ LT cable of any size with the help of fault tracing machine and rectifying the faults with required minor parts/spares as required, re-jointing the same and making functional with and including all other necessary arrangements suitable for locating the faults, complete all as specified and as directed to restore the supply, complete all as specified.Note: (i). Necessary Joint kit, Earth work, cable protection, GI pipe, Cables etc, if any needed will be measured and paid separately. (ii) T&P required for the entire job shall be provided by the contractor at his own end and nothing extra shall be admissible on this account. (iii) Fault & location thereof shall be traced within 12 hours of tele intimation by the Engineer-in-Charge / JE E&M and shall be rectified within given time frame. (iv) After 12 hours of delay, a panality of ₹ 500.00 per 3 hours shall be impossed upto 24 hours then after a penality of ₹ 6,000.00 per day. |
| 45 | Supply and laying reinforced cement concrete pipe of 120mm dia, 2 nos half round for bottom and top, laid under trench with and including excavated area shall be levelled complete all as directed by Engr-In- Charge. Note: One half round Top and One half round bottom together will be considered as one running meter. Please Enable Macros to View BoQ information |
| 46 | Supply and laying reinforced cement concrete pipe of 120mm dia, 2 nos half round for bottom and top, laid under trench with and including excavated area shall be levelled complete all as directed by Engr-In- Charge. Note: One half round Top and One half round bottom together will be considered as one running meter. Please Enable Macros to View BoQ information |