| 1 | Supply & laying, connecting and commissioning of LT UG cable 10 sqmm 4 core 1100 volts grade XLPE insulated armoured heavy duty electric cables with aluminium conductor including connecting with suitable size of cable glands lugs etc. laid in trenches or fixed on walls including taking down old unserviceable cables complete all as specified and as directed . |
| 2 | All as per Sl item No. 1.00 above but for 25 sqmm 4 core |
| 3 | All as per Sl item No. 1.00 above but for 95 sqmm 3.5 core |
| 4 | All as per Sl item No. 1.00 above but for 120 sqmm 3.5 core |
| 5 | All as per Sl item No. 1.00 above but for 240 sqmm 3.5 core |
| 6 | Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m depth and getting out in type soil for laying cables/pipes etc. complete all as specified and as directed . |
| 7 | Returning filling in, with excavated soils including spreading, levelling, watering and well ramming in layers n.exc. 25 cms thick. complete all as specified and as directed . |
| 8 | Removing excavated material to a distance n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and as directed . |
| 9 | M&L for sand cushioning with sand in two layer,first layer of 80mm thick before laying of cable and second layer of 150mm thick after laying of cable in trenches/ducts for cable including consolidation of each layer complete all as specified and as directed .Note: Punned thickness of sand cusioning shall be measured only for the purpose of payment . |
| 10 | Supply and Laying unreinforced precast concrete cable cover class LV 1 flat size of size 250x150x40 mm for protection og LT cable all sizes complete all as specified and directed . |
| 11 | Cutting the existing road / hardstanding not less than 25cm in deep and 45cm in width for laying of underground cable / pipe and making good the disturbed surfaces with PCC 1:3:6 type C2 using 40mm graded stone aggregate complete all as specified and as directed. |
| 12 | Supply and lay GI tubing 50 mm dia light grade ISI marked laid in trenches complete with all accessories such as Tees union , bend ,elbow nipple reducer etc etc as reruired for protection of UG cable on floor / pole complete all as specified and directed . |
| 13 | Supply and lay GI tubing 80 mm dia light grade ISI marked laid in trenches complete with all accessories such as Tees union , bend ,elbow nipple reducer etc etc as reruired for protection of UG cable on floor / pole complete all as specified and directed . |
| 14 | Supply & Install, test and commission factory made outdoor type / floor mounted thermoplastic polycarbonate cubical type feeder pillar box IP 65 protection suitable for 3 phase 4 wire 415 V, 50 Hz of suitable panel size with 400 Amps rated aluminium busbar, internal wiring connection with suitable size copper cables and MS angle iron based frame painted with two coats of synthetic enamel paint over a coat of red oxide primer , LT feeder pillar box shall be manufactured by CPRI approved manufacturer including PCC foundation to accomodate and comprising of with the following including dismantling of old feeder pillar box complete all as specified and as directed. (Location - Back side of children park) (i) MCCB 4 Pole, 415V 250 Amps, 36 kA-01 No (incoming) (ii) MCCB 4 pole, 415V 100 Amps 25 kA - 03 No (outgoing) (iii) MCB TPN 32 Amps, 10 KA - 03 No (outgoing)(iv) MCB DP/SPN 20 Amps , 10 KA - 02 No(v) Digital voltmeter 0-500 V - 01 No (vi) Digital ammeter with CTs 250 amps- 01 No(vii) Indicator lamp LED type 240V AC (RYB) - 01 set |
| 15 | Supply & Install, test and commission factory made outdoor type / floor mounted thermoplastic polycarbonate cubical type feeder pillar box IP 65 protection suitable for 3 phase 4 wire 415 V, 50 Hz of suitable panel size with 400 Amps rated copper busbar, internal wiring connection with suitable size copper cables and MS angle iron based frame painted with two coats of synthetic enamel paint over a coat of red oxide primer , LT feeder pillar box shall be manufactured by CPRI approved manufacturer , including PCC foundation to accomodate and comprising of with the following including dismantling of old feeder pillar box complete all as specified and as directed. (Location - Back side of children park for Admin and MSO bldg) (i) Change over switch TPN 415V 250 amps , 25 KA -01 No ( incoming) (ii) MCCB 4 pole 415V 63 Amps, 25 kA-05 (outgoing)(ii) MCCB 4 pole, 415V 40 Amps 25 kA - 04 (outgoing)(iii) MCB TP 32 Amps, 10 KA - 03 No (outgoing)(iv) MCB SPN 20 Amps , 10 KA - 03 No(v) Digital voltmeter 0-500 V - 01 No (vi) Digital ammeter with CTs 250 amps- 01 No(vii) Indicator lamp LED type 240V AC (RYB) - 01 set |
| 16 | Supply & Install, test and commission factory made outdoor type / floor mounted thermoplastic polycarbonate cubical type feeder pillar box IP 65 protection suitable for 3 phase 4 wire 415 V, 50 Hz of suitable panel size with 400 Amps rated aluminium busbar, internal wiring connection with suitable size copper cables and MS angle iron based frame painted with two coats of synthetic enamel paint over a coat of red oxide primer , LT feeder pillar box shall be manufactured by CPRI approved manufacturer including PCC foundation to accomodate and comprising of with the following including dismantling of old feeder pillar box complete all as specified and as directed. (Location - Near MI room) (i) MCCB 4 Pole, 415V 250 Amps, 36 kA-01 (incoming) (ii) MCCB 4 pole, 415V 100 Amps 25 kA - 08 (outgoing) (iii) MCB FP 32 Amps, 10 KA - 03 No(iv) MCB DP 20 Amps , 10 KA - 03 No(v) Digital voltmeter 0-500 V - 01 No (vi) Digital ammeter with CTs 125/5 Amps - 01 No (vii) Tamper proof digital KWH energy meter with CTs - 01 No (viii) Indicator lamp LED type 240V AC (RYB) - 01 set |
| 17 | Supply & Install, test and commission factory made outdoor type / floor mounted thermoplastic polycarbonate cubical type feeder pillar box IP 65 protection suitable for 3 phase 4 wire 415 V, 50 Hz of suitable panel size with 250 Amps rated Aluminium busbar, internal wiring connection with suitable size copper cables and MS angle iron based frame painted with two coats of synthetic enamel paint over a coat of red oxide primer , LT feeder pillar box shall be manufactured by CPRI approved manufacturer , including PCC foundation to accomodate and comprising of with the following including dismantling of old feeder pillar box complete all as specified and as directed. (Location - Back side of MSO bldg) (i) MCCB 4 pole 415V 63 Amps, 25 kA-01 (incoming) (ii) MCB 4 pole, 415V 40 Amps 10 kA - 02 (outgoing)(iii) MCB DP 32 Amps, 10KA - 04 No (outgoing)(iv) Digital timer switch 24 hr - 02 No(v) 40 A TP contractor - 02 No (vi) A/O/M selector switch - 02 No |
| 18 | Supply & Install, test and commission factory made indoor type / floor mounted thermoplastic polycarbonate cubical type feeder pillar box IP 65 protection suitable for 3 phase 4 wire 415 V, 50 Hz of suitable panel size with 63 Amps rated aluminium busbar, internal wiring connection with suitable size copper cables and MS angle iron based frame painted with two coats of synthetic enamel paint over a coat of red oxide primer , LT feeder pillar box shall be manufactured by CPRI approved manufacturer including PCC foundation to accomodate and comprising of with the following including dismantling of old feeder pillar box complete all as specified and as directed. (Location - Back side Cheriyapani bldg) (i) MCB 4 pole 40 Amps, 10 KA-01 (incoming) (ii) 5 HP 3 Ph DOL starter - - 02 (outgoing) (iii) MCB SPN, 20 Amps 10 KA - 02 (outgoing) (iv) Digital Multification meter- 01 (v) 40/5 CTs Amps - 03 No (vii) Indicator lamp LED type 240V AC (RYB) - 01 set |
| 19 | Supply & Install, test and commission factory made indoor type / floor mounted thermoplastic polycarbonate cubical type feeder pillar box IP 65 protection suitable for 3 phase 4 wire 415 V, 50 Hz of suitable panel size with 400 Amps rated aluminium busbar, internal wiring connection with suitable size copper cables and MS angle iron based frame painted with two coats of synthetic enamel paint over a coat of red oxide primer , LT feeder pillar box shall be manufactured by CPRI approved manufacturer including PCC foundation to accomodate and comprising of with the following including dismantling of old feeder pillar box complete all as specified and as directed. (Location- Near kavaratti bldg) (i) MCCB 4 pole 415V 400 Amps, 36 KA-01 (incoming) (ii) MCCB 4 pole 415V 250 Amps, 36 KA-04 (outgoing) (iii) MCB FP, 40 Amps 10 kA - 03 (iv) MCB DP, 32 Amps 10 kA - 04 (v) Digital Multification meter- 01 (vi) 400/5 CTs Amps - 03 No (vii) Indicator lamp LED type 240V AC (RYB) - 01 set |
| 20 | Earthing complete with galvanized iron earth plate electrode 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr below ground level connecting to the Galvanised iron earth lead 32x6 mm size, by means nut, bolt, check nuts and washer of galvanized earh strip 32x6 mm as earth lead protected by provision of GI light grade pipe 40mm bore including concrete pit in PCC (1:2:4) type B-1 using 20mm graded stone aggregate with 40mm thick cover of RCC (1:2:4) reinforced (weight not less than 4Kg / Sqm) and frame of angle iron 25x25x6mm with lugs 2 Nos and with 6mm dia MS bar handle made to shape, GI light grade 20mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge of earth plate, common salt and charcoal filling, test point with fixing arrangement CI funnel wire mesh and earth work in hard/dense soil, returning filling in and removal of surplus soil to a distance not exc 50 mtr all as per electrical plate No.3 of SSR Part I and connecting to earth test point and testing including dismantling of old earthing complete all as specified and as directed . |
| 21 | S&F in replacement of street light brackets made out of 40mm bore GI tubing, light grade, 1.5m long, bent to required shape, including necessary bending, welding, etc fixed with 2Nos. clamps made out of 32x5mm GI strip including necessary drilling holes, screws, nuts, bolts, etc complete all as specified and as directed |
| 22 | S&F in replacement of LED street light fitting 30 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and as directed . |
| 23 | S&F in replacement of LED gate light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and as directed |
| 24 | S&F in replacement of LED bollard light fitting 08 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and as directed . |
| 25 | S&F in replacement of LED flood light fitting 30 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and as directed . |
| 26 | S & F FRP boxes made with 4 way connectors heavy duty MCB SP 6 Amps - 01 No with GI clamps made out of 32x6 mm and GI nuts, bolts etc complete including taking down old box complete all as specifed and as directed . Please Enable Macros to View BoQ information |