| 1 | Supply of Equipments and Material |
| 2 | 16 Core, 2.5 sq mm, 1100 V, PVC insulated, PVC sheathed, FRLS, galvanised steel wire/ strip armoured stranded copper conductor control cable (Makes mentioned in SBD) |
| 3 | 12 Core, 2.5 sq mm, 1100 V, PVC insulated, PVC sheathed, FRLS, galvanised steel wire/ strip armoured stranded copper conductor control cable (Makes mentioned in SBD) |
| 4 | 4 Core, 10 sq mm, 1100 V, PVC insulated, PVC sheathed, FRLS, galvanised steel wire/ strip armoured stranded copper conductor control cable (Makes mentioned in SBD) |
| 5 | 4 Core, 6 sq mm, 1100 V, PVC insulated, PVC sheathed, FRLS, galvanised steel wire/ strip armoured stranded copper conductor control cable (Makes mentioned in SBD) |
| 6 | cable glands, feruls etc |
| 7 | 36kV, 50c/s , 2500 Amp, 31.5kA for one second, Ac motor operated horizontal double break, outdoor type 3 pole Isolators without earth switches |
| 8 | 36kV, 50c/s , 2500 Amp, 31.5kA for one second, Ac motor operated horizontal double break, outdoor type 3 pole Isaolators with earth switches |
| 9 | Single phase, 50 c/s 36KV Current Transformers (1200-600-300 /1-1-1 A or as per site specifications) , 31.5KA for one second, rated dynamic current 25KA(peak), Class A insulation, Burden 20 VA Acc. 0.2s |
| 10 | Single Phase 36KV 50 c/s, outdoor metal oxide gapless type, 30KV (rms) Surge Arrestor class 3 including Surge counters/monitors, insulating base all associated accessories, auxiliaries. |
| 11 | Single phase, 50 c/s 33 kv PT (33/√3) kv/110/√3) v, with highest system voltage 36 kv, 1 min power freq. withstand 70 kv rms. |
| 12 | 33KV VCB (36 KV, 2000 Amps of 3 phase, 50 c/s and 31.5KA for 3 sec) outdoor type with all accessories and auxiliaries and mandatory spare. (Makes mentioned in SBD) |
| 13 | 33KV Control and Relay Panel for Line/Feeder completely wired including Substation automation supporting IEDs/numerical relays of make ABB/SIEMENS/GE/ALSTHOM/SCHNEIDER with IEC 61850 compatibility, with under frequency relay, E/F and O/C (Main and Backup Protection) |
| 14 | Clamps of sorts ( T clamp, pad clamp, ct clamps) |
| 15 | Power Conductor ACSR Zebra 420 MM² |
| 16 | Erection of Equipments and Material |
| 17 | 16 Core, 2.5 sq mm, 1100 V, PVC insulated, PVC sheathed, FRLS, galvanised steel wire/ strip armoured stranded copper conductor control cable complete Job (Makes mentioned in SBD) |
| 18 | 12 Core, 2.5 sq mm, 1100 V, PVC insulated, PVC sheathed, FRLS, galvanised steel wire/ strip armoured stranded copper conductor control cable complete Job (Makes mentioned in SBD) |
| 19 | 4 Core, 10 sq mm, 1100 V, PVC insulated, PVC sheathed, FRLS, galvanised steel wire/ strip armoured stranded copper conductor control cable complete Job (Makes mentioned in SBD) |
| 20 | 4 Core, 6 sq mm, 1100 V, PVC insulated, PVC sheathed, FRLS, galvanised steel wire/ strip armoured stranded copper conductor control cable complete Job (Makes mantioned in SBD) |
| 21 | cable glands, feruls etc |
| 22 | 36kV, 50c/s , 2500 Amp, 31.5kA for one second, Ac motor operated horizontal double break, outdoor type 3 pole Isolators without earth switches |
| 23 | 36kV, 50c/s , 2500 Amp, 31.5kA for one second, Ac motor operated horizontal double break, outdoor type 3 pole Isolators with earth switches |
| 24 | Single phase, 50 c/s 36KV Current Transformers (1200-600-300 /1-1-1 A or as per site specifications) , 31.5KA for one second, rated dynamic current 25KA(peak), Class A insulation, Burden 20 VA Acc. 0.2s |
| 25 | Single Phase 36KV 50 c/s, outdoor metal oxide gapless type, 30KV (rms) Surge Arrestor class 3 including Surge counters/monitors, insulating base all associated accessories, auxiliaries. |
| 26 | Single phase, 50 c/s 33 kv PT (33/√3) kv/110/√3) v, with highest system voltage 36 kv, 1 min power freq. withstand 70 kv rms. |
| 27 | 33KV VCB (36 KV, 2000 Amps of 3 phase, 50 c/s and 31.5KA for 3 sec) outdoor type with all accessories and auxiliaries and mandatory spare. |
| 28 | 33KV Control and Relay Panel for Line/Feeder completely wired including Substation automation supporting IEDs/numerical relays of make ABB/SIEMENS/GE/ALSTHOM/SCHNEIDER with IEC 61850 compatibility, with under frequency relay, E/F and O/C (Main and Backup Protection) |
| 29 | Clamps of sorts ( T clamp, pad clamp, ct clamps) |
| 30 | Power Conductor ACSR Zebra 420 MM² |
| 31 | Dismanteling of Equipments and Material and write back to Divisional Store |
| 32 | Control Cable 16 Core X 2.5 sq mm (Makes mentioned in SBD) |
| 33 | Control Cable 12 Core X 2.5 sq mm (Makes mentioned in SBD) |
| 34 | Control Cable 4 Core X 10 sq mm (Makes mentioned in SBD) |
| 35 | Control Cable 4 Core X 6 sq mm (Makes mentioned in SBD) |
| 36 | cable glands, feruls etc |
| 37 | 36kV, 50c/s , 2500 Amp, 31.5kA for one second, Ac motor operated horizontal double break, outdoor type 3 pole Isolators without earth switches |
| 38 | 36kV, 50c/s , 2500 Amp, 31.5kA for one second, Ac motor operated horizontal double break, outdoor type 3 pole Isolators with earth switches |
| 39 | Single phase, 50 c/s 36KV Current Transformers |
| 40 | Single Phase 36KV 50 c/s, outdoor metal oxide gapless type. |
| 41 | Single phase, 50 c/s 33 kv Potential Transformer |
| 42 | 33KV VCB outdoor type with all accessories and auxiliaries and mandatory spare. |
| 43 | 33KV Control and Relay Panel for Line/Feeder completely with allied relays and accessories. |
| 44 | Clamps of sorts ( T clamp, pad clamp, ct clamps) |
| 45 | Power Conductor ACSR Zebra 420 MM² |
| 46 | Supply of T & P Items/ Safety Items in Divisional store of TLMD-III Udhampur |
| 47 | Safety Gloves ISI |
| 48 | Safety Shoes ISI |
| 49 | Safety Helmet ISI |
| 50 | Chargable Led Search Light |
| 51 | Fire Extinguishers ABC Dry Powder type 9 Kg |
| 52 | Clamp on Meter (Reputed brands) |
| 53 | Spanners (6 No. to 32 No.) |
| 54 | Plier (8 Inches) |
| 55 | Screw driver 12 Inches Please Enable Macros to View BoQ information |